WorldWideScience

Sample records for colloid microprobe analysis

  1. Metallographic study of ferrite → sigma transformation using ferromagnetic colloid, microprobe analysis, and color etching

    Gray, R.J.; Crouse, R.S.; Sikka, V.K.; King, R.T.

    1976-01-01

    The mechanical properties of ferrite-containing austenitic stainless steel base metal and weldments are usually adversely affected by prolonged exposure to temperatures in the 482-900 0 C (900-1652 0 F) range. One cause of the property alteration is related to the transformation of relatively ductile delta-ferrite to less ductile sigma-phase. Attempts to identify sigma and delta ferrite phases by color staining techniques alone are well documented; however, the results are often questionable due to the difficulty in maintaining consistent color identifications. This investigation is concerned with the microstructural responses of the ferromagnetic delta-ferrite phase and the paramagnetic sigma-phase to a ferromagnetic iron colloid in a magnetic field. Such positive or negative responses of the two phases to the colloid offer a more definitive identification. With this technique, the identification of small amounts of these phases in the microstructure is limited only by the highest magnification and resolution of the optical microscope. The procedure is substantiated in this metallographic study with microprobe analysis and color metallography. Several examples of the correlative use of these three techniques in identifying varying amounts of delta-ferrite yields sigma transformation are presented

  2. Detection of delta-ferrite to sigma transformation using metallographic techniques involving ferromagnetic colloid, color etching, and microprobe analysis

    Gray, R.J.; Sikka, V.K.; King, R.T.

    1976-01-01

    The mechanical properties of ferrite-containing austenitic stainless steel base metal and weldments are usually adversely affected by prolonged exposure to temperatures in the 482 to 900 0 C (900 to 1652 0 F) range. One cause of the property alteration is related to the transformation of relatively ductile delta-ferrite to less ductile sigma-phase. Attempts to identify sigma and delta-ferrite phases by color staining techniques alone are well documented; however, the results are often questionable due to the difficulty in maintaining consistent color identifications. This investigation is concerned with the microstructural responses of the ferromagnetic delta-ferrite phase and the paramagnetic sigma-phase to a ferromagnetic iron colloid in a magnetic field. Such positive or negative responses of the two phases to the colloid offer a more definitive identification. With this technique, the identification of small amounts of these phases in the microstructure is limited only by the highest magnification and resolution of the optical microscope. The procedure is substantiated in this metallographic study with microprobe analysis and color metallography. Several examples of the correlative use of these three techniques in identifying varying amounts of delta-ferrite → sigma transformation are presented

  3. Microprobe analysis in human pathology

    Baker, D.; Kupke, K.G.; Ingram, P.; Roggli, V.L.; Shelburne, J.D.

    1985-01-01

    This tutorial paper reviews the literature on the application of microprobe analysis to practical problems in diagnostic human pathology. The goal is to allow the reader ready access to the literature on specific clinical problems. Specimen preparation and commonly encountered artifacts are also considered. It is concluded that energy dispersive x-ray microanalysis and back-scattered electron imaging are at present the most generally useful microprobe techniques for clinical work, and are no longer solely research tools. The findings often have diagnostic, therapeutic, and/or legal implications. 332 references

  4. Microprobe analysis of human fibroblasts

    Allan, G.L.; Zhu, J.; Legge, G.J.F.

    1985-01-01

    The Melbourne Proton Microprobe has been used to study the copper content in human skin fibroblast cells derived from patients with the genetic disease Menkes Syndrome. Both normal and diseased cells have been studied to investigate any elemental differences occurring between the two cell types. This paper details the preparatory techniques necessary for individual cell analysis and presents the elemental information with a new three dimensional contour mapping technique. These maps are used to highlight elemental differences between normal and mutant fibroblasts. The work also confirms the expected copper excess found in the Menkes cell and indicates that the microprobe can be used for rapid identification of a Menkes carrier

  5. Biological analysis with a nuclear microprobe

    Cookson, J.A.; Legge, G.J.F.

    1975-01-01

    Most low-energy nuclear accelerators are now partly used on analytical studies in support of sciences other than nuclear physics. This paper gives a short review of such analytical techniques (X-ray analysis, elastic scattering analysis, nuclear reaction analysis, and the nuclear microprobe) with particular reference to biological applications and also emphasizes the role of the positional analysis that can be performed with a focused beam of ions - the nuclear microprobe. (author)

  6. Materials analysis with a nuclear microprobe

    Maggiore, C.J.

    1980-01-01

    The ability to produce focused beams of a few MeV light ions from Van de Graaff accelerators has resulted in the development of nuclear microprobes. Rutherford backscattering, nuclear reactions, and particle-induced x-ray emission are used to provide spatially resolved information from the near surface region of materials. Rutherford backscattering provides nondestructive depth and mass resolution. Nuclear reactions are sensitive to light elements (Z < 15). Particle-induced x-ray analysis is similar to electron microprobe analysis, but 2 orders of magnitude more sensitive. The focused beams are usually produced with specially designed multiplets of magnetic quadrupoles. The LASL microprobe uses a superconducting solenoid as a final lens. The data are acquired by a computer interfaced to the experiment with CAMAC. The characteristics of the information acquired with a nuclear microprobe are discussed; the means of producing the beams of nuclear particles are described; and the limitations and applications of such systems are given

  7. Microprobe analysis of carbon gradients

    Lamothe, M.; Convert, F.

    1987-01-01

    Problems arising in carbon analysis and how they are solved are presented: sample pollution limitation using cold trap and gas jet cleaning sample preparation, carbon content determination and calibration, automation and optimization. Examples given include concentration monitoring. Carbon homogeneity after complete cementation and decarburization by heat treatment. 6 refs, 14 figs [fr

  8. Microprobe channeling analysis of pyrite crystals

    Jamieson, D.N.; Ryan, C.G.

    1992-01-01

    Nuclear microprobe analysis has provided much useful information about the composition of microscopic inclusions in minerals, mainly through the use of Particle Induced X-ray Emission (PIXE). However this technique, while powerful, does not provide any direct information about the chemical state, in particular the lattice location, of the elements in the mineral. This information is often of crucial importance in understanding the ore genesis. The technique of ion channeling may be used to identify lattice location, but many minerals occur as microscopic crystals. Therefore it is necessary to utilize a nuclear microprobe with the technique of Channeling Contrast Microscopy (CCM). As many minerals contain interesting trace elements, it is necessary to measure both the yield of backscattered particles and the induced x-rays to get a clear picture of the lattice location of the elements in the crystal. CCM with PIXE was used to analyse natural pyrite crystals containing a variety of substitutional and non-substitutional elements and natural pyrite crystals from a gold bearing ore. In the latter case, evidence was obtained for two habits for Au in the 400 μm crystals: one as inclusions of Au rich minerals, the other substituted on the pyrite lattice sites. 31 refs., 3 tabs., 6 figs

  9. Electron microprobe analysis of tantalum--nitride thin films

    Stoltz, D.L.; Starkey, J.P.

    1979-06-01

    Quantitative chemical analysis of 500- and 2000-angstrom tantalum--nitride films on glass substrates has been accomplished using an electron microprobe x-ray analyzer. In order to achieve this analysis, modifications to the microprobe were necessary. A description of the calibration procedure, the method of analysis, and the quantitative results are discussed

  10. Ion microprobe analysis of metallic pigments

    Pelicon, P.; Simcic, J.; Budnar, M.; Klanjsek-Gunde, M.; Kunavaer, M.

    2001-01-01

    Full text: Metallic paints consist of metallic flakes dispersed m a resinous binder, i.e. a light-element polymer matrix. The spatial distribution and orientation of metallic flakes inside the matrix determines the covering efficiency of the paint, glossiness, and its angular-dependent properties such as lightness flop or color flop (two-tone). Such coatings are extensively used for a functional (i.e. security) as well as decorative purpose. The ion microbeam analysis of two types of silver paint with imbedded metallic flake has been performed to test the ability of the ion microbeam spectroscopic methods on this type of samples. The average sizes of the aluminium flakes were 23 (size distribution 10-37) and 49 (size distribution 34-75) micrometers, respectively. The proton beam with the size of 2x2 micrometers at Ljubljana ion microprobe has been used to scan the surface of the pigments. PIXE mapping of Al Kα map shows lateral distribution of the aluminum flakes, whereas the RBS slicing method reveals tomographic image of the flakes in uppermost 5 micrometers of the pigment layer. The flake distribution in the larger layer depths has been accessed by RBS analysis in a point mode. (author)

  11. Multidimensional elemental analysis with the Sandia nuclear microprobe

    Doyle, B.L.

    1988-01-01

    It is well known that many of the ion beam analysis techniques such as Rutherford backscattering spectrometry, elastic recoil detection, resonant and nonresonant nuclear reaction analysis can be used to nondestructively obtain concentration depth profiles of elements in solids. When these techniques are combined with the small beam spot capabilities of a scanned nuclear microprobe, sample composition can be determined in up to three dimensions. This paper will review the various procedures used to collect and analyze multidimensional data using the Sandia nuclear microprobe. In addition, examples of how these data are being used in the study of materials will be shown. (author)

  12. Proton microprobe analysis of pancreatic. beta. cells

    Lindh, U [Uppsala Univ. (Sweden). Gustaf Werner Inst.; Juntti-Berggren, L; Berggren, P O; Hellman, B [Uppsala Univ. (Sweden)

    1985-01-01

    Freeze-dried pancreas sections from obese hyperglycemic mice were subjected to proton bombardment and the elemental contents in the ..beta.. cells and the exocrine part were obtained from the characteristic X-rays emitted. Quantitative data were provided for 18 different elements. The mole ratio between K and Na exceeded 10, implying that neither the sample preparation nor the irradiation had induced significant diffuse changes. With the demonstration of this high K/Na ratio it seems likely that also the ..beta.. cells are equipped with an efficient Na/sup +//K/sup +/ pump. The ..beta.. cells contained about 70 mmoles Cl per litre cell water. Observed amounts of Ca and Mg were equivalent to those previously recorded by electrothermal atomic absorption spectroscopy. The significant role of Zn for the storage of insulin was emphasized by the demonstration of 3 times as much of this element in the ..beta.. cells as compared with the exocrine pancreas. In addition, the sensitivity of the proton microprobe enabled measurements of various trace elements such as Rb, Cr, Cu, Al and Pb not previously demonstrated in the pancreatic ..beta.. cells.

  13. Analysis of colloid transport

    Travis, B.J.; Nuttall, H.E.

    1985-01-01

    The population balance methodology is described and applied to the transport and capture of polydispersed colloids in packed columns. The transient model includes particle growth, capture, convective transport, and dispersion. We also follow the dynamic accumulation of captured colloids on the solids. The multidimensional parabolic partial differential equation was solved by a recently enhanced method of characteristics technique. This computational technique minimized numerical dispersion and is computationally very fast. The FORTRAN 77 code ran on a VAX-780 in less than a minute and also runs on an IBM-AT using the Professional FORTRAN compiler. The code was extensively tested against various simplified cases and against analytical models. The packed column experiments by Saltelli et al. were re-analyzed incorporating the experimentally reported size distribution of the colloid feed material. Colloid capture was modeled using a linear size dependent filtration function. The effects of a colloid size dependent filtration factor and various initial colloid size distributions on colloid migration and capture were investigated. Also, we followed the changing colloid size distribution as a function of position in the column. Some simple arguments are made to assess the likelihood of colloid migration at a potential NTS Yucca Mountain waste disposal site. 10 refs., 3 figs., 1 tab

  14. X-ray Microprobe for Fluorescence and Diffraction Analysis

    Ice, G.E.

    2005-01-01

    X-ray diffraction (see unit 1.1) and x-ray excited fluorescence analysis are powerful techniques for the nondestructive measurement of crystal structure and chemical composition. X-ray fluorescence analysis is inherently nondestructive with orders of magnitude lower power deposited for the same detectable limit as with fluorescence excited by charged particle probes (Sparks, 1980). X-ray diffraction analysis is sensitive to crystal structure with orders-of-magnitude greater sensitivity to crystallographic strain than electron probes (Rebonato, et al. 1989). When a small-area x-ray microbeam is used as the probe, chemical composition (Z>14), crystal structure, crystalline texture, and crystalline strain distributions can be determined. These distributions can be studied both at the surface of the sample and deep within the sample (Fig. 1). Current state-of-the-art can achieve an ∼1 mm-D x-ray microprobe and an ∼0.1 mm-D x-ray microprobe has been demonstrated (Bilderback, et al., 1994). Despite their great chemical and crystallographic sensitivities, x-ray microprobe techniques have until recently been restricted by inefficient x-ray focusing optics and weak x-ray sources; x-ray microbeam analysis was largely superseded by electron techniques in the 50's. However, interest in x-ray microprobe techniques has now been revived (Howells, et al., 1983; Ice and Sparks, 1984; Chevallier, et al., 1997; Riekel 1992; Thompson, el al., 1992; and Making and Using... 1997) by the development of efficient x-ray focusing optics and ultra-high intensity synchrotron x-ray sources (Buras and Tazzari, 1984; Shenoy, et al., 1988). These advances have increased the achievable microbeam flux by more than 11 orders of magnitude (Fig. 2) (Ice, 1997); the flux in a tunable 1 mm-D beam on a 'so called' 3rd-generation synchrotron source such as the APS can exceed the flux in a fixed-energy mm2 beam on a conventional source. These advances make x-ray microfluorescence and x

  15. Microprobe PIXE analysis and EDX analysis on the brain of patients with Alzheimer's disease

    Yumoto, S.; Horino, Y.; Mokuno, Y.; Fujii, K.; Kakimi, S.; Mizutani, T.; Matsushima, H.; Ishikawa, A.

    1996-01-01

    To investigate the cause of Alzheimer's disease (senile dementia of Alzheimer's disease type), we examined aluminium (Al) in the brain (hippocampus) of patients with Alzheimer's disease using heavy ion (5 MeV Si 3+ ) microprobe particle-induced X-ray emission (PIXE) analysis. Heavy ion microprobes (3 MeV Si 2+ ) have several times higher sensitivity for Al detection than 2 MeV proton microprobes. We also examined Al in the brain of these patients by energy dispersive X-ray spectroscopy (EDX). (1) Al was detected in the cell nuclei isolated from the brain of patients with Alzheimer's disease using 5 MeV Si 3+ microprobe PIXE analysis, and EDX analysis. (2) EDX analysis demonstrated high levels of Al in the nucleolus of nerve cells in frozen sections prepared from the brain of these patients. Our results support the theory that Alzheimer's disease is caused by accumulation of Al in the nuclei of brain cells. (author)

  16. Analysis of biological materials using a nuclear microprobe

    Mulware, Stephen Juma

    The use of nuclear microprobe techniques including: Particle induced x-ray emission (PIXE) and Rutherford backscattering spectrometry (RBS) for elemental analysis and quantitative elemental imaging of biological samples is especially useful in biological and biomedical research because of its high sensitivity for physiologically important trace elements or toxic heavy metals. The nuclear microprobe of the Ion Beam Modification and Analysis Laboratory (IBMAL) has been used to study the enhancement in metal uptake of two different plants. The roots of corn (Zea mays) have been analyzed to study the enhancement of iron uptake by adding Fe (II) or Fe(III) of different concentrations to the germinating medium of the seeds. The Fe uptake enhancement effect produced by lacing the germinating medium with carbon nanotubes has also been investigated. The aim of this investigation is to ensure not only high crop yield but also Fe-rich food products especially from calcareous soil which covers 30% of world's agricultural land. The result will help reduce iron deficiency anemia, which has been identified as the leading nutritional disorder especially in developing countries by the World Health Organization. For the second plant, Mexican marigold (Tagetes erecta ), the effect of an arbuscular mycorrhizal fungi (Glomus intraradices ) for the improvement of lead phytoremediation of lead contaminated soil has been investigated. Phytoremediation provides an environmentally safe technique of removing toxic heavy metals (like lead), which can find their way into human food, from lands contaminated by human activities like mining or by natural disasters like earthquakes. The roots of Mexican marigold have been analyzed to study the role of arbuscular mycorrhizal fungi in enhancement of lead uptake from the contaminated rhizosphere.

  17. Milliprobe and microprobe analysis of gold items of ancient jewellery

    Demortier, G.; Hackens, T.

    It has long been accepted that the presence of cadmium implies a condemnation of the authenticity of an ancient gold object, or at least, of the part of the object where the cadmium is detected. An analysis in Paris of a recently excavated object from Roman times has shown cadmium. Meanwhile, systematic observations were made at L.A.R.N. on objects dating from Hellenistic to Byzantine times with different given origins (objects from a museum and from private collections). By using PIXE with a 3 MeV proton milliprobe (700 μm beam diameter) in a non vacuum geometry, relative amounts of copper, silver, cadmium and gold at the surface of more than 30 gold objects expected to be ancient have been determined. Traces or significant concentrations of cadmium have been detected at several points on or in the neighbourhood of solders on many objects which seem to be from Roman to early Byzantine times. Cadmium concentrations range between 2 to 100 parts per thousand. This range of variations and the relative concentrations of Au, Ag, Cu and Cd at the surface of the objects studied are often different from the figures obtained during analyses of modern soldering alloys. Experiments with the L.A.R.N. proton microprobe (5 μm x 10 μm area) allow a still better topographical resolution and more significative comparison of the relative amounts of the elements of interest in modern soldering alloys and supposedly old solders. The usefulness of the microprobe is demonstrated. (author)

  18. Synchrotron radiation microprobe quantitative analysis method for biomedical specimens

    Xu Qing; Shao Hanru

    1994-01-01

    Relative changes of trace elemental content in biomedical specimens are obtained easily by means of synchrotron radiation X-ray fluorescence microprobe analysis (SXRFM). However, the accurate assignment of concentration on a g/g basis is difficult. Because it is necessary to know both the trace elemental content and the specimen mass in the irradiated volume simultaneously. the specimen mass is a function of the spatial position and can not be weighed. It is possible to measure the specimen mass indirectly by measuring the intensity of Compton scattered peak for normal XRF analysis using a X-ray tube with Mo anode, if the matrix was consisted of light elements and the specimen was a thin sample. The Compton peak is not presented in fluorescence spectrum for white light SXRFM analysis. The continuous background in the spectrum was resulted from the Compton scattering with a linear polarization X-ray source. Biomedical specimens for SXRFM analysis, for example biological section and human hair, are always a thin sample for high energy X-ray, and they consist of H,C,N and O etc. light elements, which implies a linear relationship between the specimen mass and the Compton scattering background in the high energy region of spectrum. By this way , it is possible to carry out measurement of concentration for SXRFM analysis

  19. Using the ion microprobe mass analyser for trace element analysis

    Schilling, J.H.

    1978-01-01

    Most techniques for the analysis of trace elements are capable of determining the concentrations in a bulk sample or solution, but without reflecting their distribution. In a bulk analysis therefore elements which occur in high concentration in a few precipitates would still be considered trace elements even though their local concentration greatly exceed the normally accepted trace elements concentration limit. Anomalous distribution is also shown by an oxide layer, a few hundred Angstrom thick, on an aluminium sample. A low oxide concentration would be reported if it were included in the bulk analysis, which contradicts the high surface concentration. The importance of a knowledge of the trace element distribution is therefore demonstrated. Distributional trace element analysis can be carried out using the ion microprobe mass analyser (IMMA). Since the analytical technique used in this instrument, namely secondary ion mass spectrometry (SIMS), is not universally appreciated, the instrument and its features will be described briefly followed by a discussion of quantitative analysis and the related subjects of detection limit and sample consumption. Finally, a few examples of the use of the instrument are given

  20. Proton microprobe analysis of zinc in skeletal tissues

    Doty, S. B.; Jones, K. W.; Kraner, H. W.; Shroy, R. E.; Hanson, A. L.

    1981-03-01

    A proton microprobe with windowless exit port has been used to study zinc distributions in various types of skeletal tissues. The use of an external beam facilitated positioning of the targets for examination of particular points of interest. The proton microprobe is uniquely suited to this work since it combines high sensitivity for zinc determination in thick samples with good spatial resolution. Our measurements on rat and rabbit Achilles tendon showed a significant increase in zinc concentrations as the beam moved from the unmineralized collagen into the mineralized attachment site. Cartilage gave a similar result, with calcified cartilage having a greater zinc level than the articular surface on unmineralized epiphyseal cartilage.

  1. Proton microprobe analysis of zinc in skeletal tissues

    Doty, S.B.; Jones, K.W.; Kraner, H.W.; Shroy, R.E.; Hanson, A.L.

    1980-06-01

    A proton microprobe with windowless exit port was used to study zinc distributions in various types of skeletal tissues. The use of an external beam facilitated positioning of the targets for examination of particular points of interest. The proton microprobe is uniquely suited to this work since it combines high sensitivity for zinc determinations in thick samples with good spatial resolution. Measurements on rat and rabbit Achilles tendon showed a significant increase in zinc concentrations as the beam moved from the unmineralized collagen into the mineralized attachment site. Cartilage gave a similar result, with calcified cartilage having a greater zinc level than the articular surface on unmineralized epiphyseal cartilage

  2. Elemental composition of paint cross sections by nuclear microprobe analysis

    Nens, B.; Trocellier, P.; Engelmann, C.; Lahanier, C.

    1982-09-01

    Physico-chemical characterization of pigments used in artistic painting give precious indications on age of paintings and sometimes on geographical origin of ores. After recalling the principle of protons microprobe, first results obtained by microanalysis of painting cross sections for non destructive microanalysis of impurities in white lead are given [fr

  3. Technique Development to Support Clean-up and/or Disposal of Actinide Contaminated Soils and Sediments: Coupling Fission Tract Analysis with Synchroton X-ray Microprobe Analysis

    Sue Clark

    2003-01-01

    The overall goal of this project was to develop quantitative FTA to provide images of the microscale spatial distributions of high fissile actinides sorbed to environmental particles such as sediments and colloids. We developed methods to provide absolute actinide surface concentrations on the particles, regardless of particle size. We are also working to provide particle size information by our approach. We also coupled our newly devised FTA methods with the quantitative determination of stable element distributions in the same particles using synchrotron x-ray microprobe analysis

  4. Microprobe PIXE analysis and EDX analysis on the brain of patients with Alzheimer`s disease

    Yumoto, S. [Tokyo Univ. (Japan). Faculty of Medicine; Horino, Y.; Mokuno, Y.; Fujii, K.; Kakimi, S.; Mizutani, T.; Matsushima, H.; Ishikawa, A.

    1996-12-31

    To investigate the cause of Alzheimer`s disease (senile dementia of Alzheimer`s disease type), we examined aluminium (Al) in the brain (hippocampus) of patients with Alzheimer`s disease using heavy ion (5 MeV Si{sup 3+}) microprobe particle-induced X-ray emission (PIXE) analysis. Heavy ion microprobes (3 MeV Si{sup 2+}) have several times higher sensitivity for Al detection than 2 MeV proton microprobes. We also examined Al in the brain of these patients by energy dispersive X-ray spectroscopy (EDX). (1) Al was detected in the cell nuclei isolated from the brain of patients with Alzheimer`s disease using 5 MeV Si{sup 3+} microprobe PIXE analysis, and EDX analysis. (2) EDX analysis demonstrated high levels of Al in the nucleolus of nerve cells in frozen sections prepared from the brain of these patients. Our results support the theory that Alzheimer`s disease is caused by accumulation of Al in the nuclei of brain cells. (author)

  5. Applications of heavy ion microprobe for single event effects analysis

    Reed, Robert A.; Vizkelethy, Gyorgy; Pellish, Jonathan A.; Sierawski, Brian; Warren, Kevin M.; Porter, Mark; Wilkinson, Jeff; Marshall, Paul W.; Niu, Guofu; Cressler, John D.; Schrimpf, Ronald D.; Tipton, Alan; Weller, Robert A.

    2007-01-01

    The motion of ionizing-radiation-induced rogue charge carriers in a semiconductor can create unwanted voltage and current conditions within a microelectronic circuit. If sufficient unwanted charge or current occurs on a sensitive node, a variety of single event effects (SEEs) can occur with consequences ranging from trivial to catastrophic. This paper describes the application of heavy ion microprobes to assist with calibration and validation of SEE modeling approaches

  6. Proton microprobe analysis of zinc in skeletal tissues

    Doty, S.B.; Jones, K.W.; Kraner, H.W.; Shroy, R.E.; Hanson, A.L.

    1981-01-01

    A proton microprobe with windowless exit port has been used to study zinc distributions in various types of skeletal tissues. The use of an external beam facilitated positioning of the targets for examination of particular points of interest. The proton micorprobe is uniquely suited to this work since it combines high sensitivity for zinc determinations in thick samples with good spatial resolution. Our measurements on rat and rabbit Achilles tendon showed a significant increase in zinc concentrations as the beam moved from the unmineralized collagen into the mineralized attachment site. Cartilage gave a similar result, with calcified cartilage having a greater zinc level than the articular surface on unmineralized epiphyseal cartilage. (orig.)

  7. Cryosystem for cathodoluminescence investigations by means of electron microprobe analysis

    Schreiber, J.

    1982-01-01

    A cryosystem is presented which has been designed as auxiliary equipment for electron beam microprobes used in cathodoluminescence studies. The sample holder temperature is adjustable down to 66 K with an accuracy of 0.5 K. Finally, experimental results (transmission spectra and cathodoluminescence spectra of N-doped GaP epitaxial layers at 80 K; changes in microscopic cathodoluminescence distribution at small angle grain boundaries at the (0001) plane of CdS during temperature decrease from 300 to 80 K) obtained by means of the described measuring equipment are given for illustration

  8. Microprobe analysis of teeth by synchrotron radiation: environmental contamination

    Pinheiro, T.; Carvalho, M.L.; Casaca, C.; Barreiros, M.A.; Cunha, A.S.; Chevallier, P.

    1999-01-01

    An X-ray fluorescence set-up with microprobe capabilities, installed at the Laboratoire pour l'Utilisation du Rayonnement Electromagnetique (LURE) synchrotron (France) was used for elemental determination in teeth. To evaluate the influence of living habits in dental elemental composition nine teeth collected post-mortem were analysed, five from a miner and four from a fisherman. All teeth from the fisherman were healthy. From the miner some teeth were carious and one of them was filled with metallic amalgam. Teeth were sliced under the vertical plane and each slice was scanned from the root to the enamel for elemental profile determination. The synchrotron microprobe resolution was of 100 μm and incident photons of 18 keV energy were used. The elemental concentration values found suggest heterogeneity of the teeth material. Moreover, the distinct profiles for Mn, Sr, Br and Pb were found when teeth from the miner and from the fisherman are compared which can be associated with dietary habits and environmental influence. Higher concentrations of Mn and Sr were found for the fisherman teeth. In addition, Br was only observed in this group of teeth. Pb levels are higher for the miner teeth in particular for dentine regions. The influence of amalgam, such as, increase of Zn and Hg contents in the teeth material, is only noticed for the immediate surroundings of the treated cavity

  9. Data acquisition and analysis system for the ion microprobe mass analyzer

    Darby, D.M.; Cristy, S.S.

    1979-02-01

    A computer was interfaced to an ion microprobe mass analyzer for more rapid data acquisition and analysis. The interface is designed to allow data acquisition, independent of the computer. A large data analysis package was developed and implemented. Performance of the computerized system was evaluated and compared to manual operation

  10. Nuclear microprobe analysis of lead profile in crocodile bones

    Orlic, I. E-mail: ivo@ansto.gov.au; Siegele, R.; Hammerton, K.; Jeffree, R.A.; Cohen, D.D

    2003-09-01

    Elevated concentrations of lead were found in Australian free ranging saltwater crocodile (Crocodylus porosus) bone and flesh. Lead shots were found as potential source of lead in these animals. ANSTO's heavy ion nuclear microprobe was used to measure the distribution of Pb in a number of bones and osteoderms. The aim was to find out if elevated Pb concentration remains in growth rings and if the concentration is correlated with the blood levels recorded at the time. Results of our study show a very distinct distribution of accumulated Pb in bones and osteoderms as well as good correlation with the level of lead concentration in blood. To investigate influence of ion species on detection limits measurements of the same sample were performed by using 3 MeV protons, 9 MeV He ions and 20 MeV carbon ions. Peak to background ratios, detection limits and the overall 'quality' of obtained spectra are compared and discussed.

  11. Nuclear micro-probe analysis of Arabidopsis thaliana leaves

    Ager, F.J.; Ynsa, M.D.; Dominguez-Solis, J.R.; Lopez-Martin, M.C.; Gotor, C.; Romero, L.C.

    2003-01-01

    Phytoremediation is a cost-effective plant-based approach for remediation of soils and waters which takes advantage of the remarkable ability of some plants to concentrate elements and compounds from the environment and to metabolize various molecules in their tissues, such as toxic heavy metals and organic pollutants. Nowadays, phytoremediation technology is becoming of paramount importance when environmental decontamination is concerned, due to the emerging knowledge of its physiological and molecular mechanisms and the new biological and engineering strategies designed to optimize and improve it. In addition, the feasibility of using plants for environmental cleanup has been confirmed by many different trials around the world. Arabidopsis thaliana plants can be used for basic studies to improve the technology on phytoremediation. Making use of nuclear microscopy techniques, in this paper we study leaves of wild type and transgenic A. thaliana plants grown in a cadmium-rich environment under different conditions. Micro-PIXE, RBS and SEM analyses, performed on the scanning proton micro-probe at the CNA in Seville (Spain), prove that cadmium is preferentially sequestered in the central region of epidermal trichome and allow comparing the effects of genetic modifications

  12. Dedicated accelerator and microprobe line

    Malmqvist, K.G.; Hylten, G.; Hult, M.; Haakansson, K.; Knox, J.M.; Larsson, N.P.O.; Nilsson, C.; Pallon, J.; Schofield, R.; Swietlicki, E.; Tapper, U.A.S.; Yang Changyi

    1993-01-01

    The development of a dedicated facility for nuclear microprobe analysis and the experiences from using it are discussed. The general properties of the present Lund nuclear microprobe will be described and the advantages of using a dedicated accelerator discussed. (orig.)

  13. IMAP: A complete Ion Micro-Analysis Package for the nuclear microprobe

    Antolak, A.J.; Hildner, M.L.; Morse, D.H.; Bench, G.S.

    1993-01-01

    Microprobe techniques using scanned, focused MeV ions are routinely used in Livermore for materials characterization. Comprehensive data analysis with these techniques is accomplished with the computer software package IMAP, for Ion Micro-Analysis Package. IMAP consists of a set of command language procedures for data processing and quantitative spectral analysis. Deconvolution of the data is achieved by spawning sub-processes within IMAP which execute analysis codes for each specific microprobe technique. IMAP is structured to rapidly analyze individual spectra or multi-dimensional data blocks which classify individual events by the two scanning dimensions, the energy of the detected radiation and, when necessary, one sample rotation dimension. Several examples are presented to demonstrate the utility of the package

  14. U and Pb isotope analysis of uraninite and galena by ion microprobe

    Evins, L.Z.; Sunde, T.; Schoeberg, H. [Swedish Museum of Natural History, Stockholm (Sweden). Laboratory for Isotope Geology; Fayek, M. [Univ. of Tennessee, Knoxville, TN (United States). Dept. of Geological Sciences

    2001-10-01

    Accurate isotopic analysis of minerals by ion microprobe, or SIMS (Secondary Ion Mass Spectrometry) usually requires a standard to correct for instrumental mass bias effects that occur during analysis. We have calibrated two uraninite crystals and one galena crystal to be used as ion probe standards. As part of this study we describe the analytical procedures and problems encountered while trying to establish fractionation factors for U and Pb isotopes measured in galena and uraninite. Only the intra-element isotopic mass fractionation is considered and not the interelement fractionation. Galena and uraninite were analysed with TIMS (Thermal Ionisation Mass Spectrometry) prior to SIMS. One uraninite crystal (P88) comes from Sweden and is ca 900 Ma old, the other from Maine, USA (LAMNH-30222) and is ca 350 Ma old. The galena sample comes from the Paleoproterozoic ore district Bergslagen in Sweden. SIMS analyses were performed at two different laboratories: the NORDSM facility in Stockholm, which has a high resolution Cameca IMS 1270 ion microprobe, and the Oak Ridge National Laboratory (ORNL) in Tennessee, which has a Cameca IMS 4f ion microprobe. The results show that during the analysis of galena, Pb isotopes fractionate in favour of the lighter isotope by as much as 0.5%/amu. A Pb isotope fractionation factor for uraninite was more difficult to calculate, probably due to the formation of hydride interferences encountered during analysis with the Cameca IMS 1270 ion microprobe. However, drying the sample in vacuum prior to analysis, and using high-energy filtering and a cold trap during analysis can minimise these hydride interferences. A large fractionation of U isotopes of ca 1.4%/amu in favour of the lighter isotope was calculated for uraninite.

  15. U and Pb isotope analysis of uraninite and galena by ion microprobe

    Evins, L.Z.; Sunde, T.; Schoeberg, H.; Fayek, M.

    2001-10-01

    Accurate isotopic analysis of minerals by ion microprobe, or SIMS (Secondary Ion Mass Spectrometry) usually requires a standard to correct for instrumental mass bias effects that occur during analysis. We have calibrated two uraninite crystals and one galena crystal to be used as ion probe standards. As part of this study we describe the analytical procedures and problems encountered while trying to establish fractionation factors for U and Pb isotopes measured in galena and uraninite. Only the intra-element isotopic mass fractionation is considered and not the interelement fractionation. Galena and uraninite were analysed with TIMS (Thermal Ionisation Mass Spectrometry) prior to SIMS. One uraninite crystal (P88) comes from Sweden and is ca 900 Ma old, the other from Maine, USA (LAMNH-30222) and is ca 350 Ma old. The galena sample comes from the Paleoproterozoic ore district Bergslagen in Sweden. SIMS analyses were performed at two different laboratories: the NORDSM facility in Stockholm, which has a high resolution Cameca IMS 1270 ion microprobe, and the Oak Ridge National Laboratory (ORNL) in Tennessee, which has a Cameca IMS 4f ion microprobe. The results show that during the analysis of galena, Pb isotopes fractionate in favour of the lighter isotope by as much as 0.5%/amu. A Pb isotope fractionation factor for uraninite was more difficult to calculate, probably due to the formation of hydride interferences encountered during analysis with the Cameca IMS 1270 ion microprobe. However, drying the sample in vacuum prior to analysis, and using high-energy filtering and a cold trap during analysis can minimise these hydride interferences. A large fractionation of U isotopes of ca 1.4%/amu in favour of the lighter isotope was calculated for uraninite

  16. False colour backscatter electron images and their application during electron microprobe analysis of ores and host rocks

    Cousens, D.R.; French, D.H.; Ramsden, A.R.

    1989-01-01

    The limited contrast range of conventional black and white imaging does not enable full use to be made of the dynamic range of the video signal obtained from a scanning electron microscope or microprobe. The use of false colour substantially increases the information that can be derived from such images enabling relationships to be displayed that cannot be observed in black and white. This capability is now used extensively in combination with quantitative electron microprobe analysis as a research tool for ore characterization and host rocks studies related to minerals exploration in the CSIRO Div.sion of Exploration Geoscience. Thus the CAMEBAX scanning electron microprobe has been modified to allow digital images acquisition and software (IMAGE) developed which allows false colour backscatter electron (BSE) images to be obtained during the course of routine electron microprobe analysis. 1 fig

  17. Nuclear microprobe analysis of the standard reference materials

    Jaksic, M.; Fazinic, S.; Bogdanovic, I.; Tadic, T.

    2002-01-01

    Most of the presently existing Standard Reference Materials (SRM) for nuclear analytical methods are certified for the analyzed mass of the order of few hundred mg. Typical mass of sample which is analyzed by PIXE or XRF methods is very often below 1 mg. By the development of focused proton or x-ray beams, masses which can be typically analyzed go down to μg or even ng level. It is difficult to make biological or environmental SRMs which can give desired homogeneity at such low scale. However, use of fundamental parameter quantitative evaluation procedures (absolute method), minimize needs for SRMs. In PIXE and micro PIXE setup at our Institute, fundamental parameter approach is used. For exact calibration of the quantitative analysis procedure just one standard sample is needed. In our case glass standards which showed homogeneity down to micron scale were used. Of course, it is desirable to use SRMs for quality assurance, and therefore need for homogenous materials can be justified even for micro PIXE method. In this presentation, brief overview of PIXE setup calibration is given, along with some recent results of tests of several SRMs

  18. Electron Microprobe

    Federal Laboratory Consortium — The JEOL JXA-8600 is a conventional hairpin filament thermal emission electron microprobe that is more than 20 years old. It is capable of performing qualitative and...

  19. Application of tomographic techniques to two-dimensional surface analysis using the Harwell nuclear microprobe

    Huddleston, J.; Hutchinson, I.G.; Pierce, T.B.

    1983-01-01

    Nuclear methods of surface analysis are discussed briefly, and the circumstances are described in which a two-dimensional analysis of the sample surface is desirable to enable the surface composition to be mapped accurately. Tomographic techniques of data manipulation are outlined. Data acquisition in the present case is performed by moving the sample in a defined sequence of positions, at each of which analytical data are gathered by the proton microprobe. The method and equipment are outlined. Data processing leading to the reconstruction of the image is summarised. (U.K.)

  20. The new confocal heavy ion microprobe beamline at ANSTO: The first microprobe resolution tests and applications for elemental imaging and analysis

    Pastuovic, Z.; Siegele, R.; Cohen, D. D.; Mann, M.; Ionescu, M.; Button, D.; Long, S.

    2017-08-01

    The Centre for Accelerator Science facility at ANSTO has been expanded with the new NEC 6 MV ;SIRIUS; accelerator system in 2015. In this paper we present a detailed description of the new nuclear microprobe-Confocal Heavy Ion Micro-Probe (CHIMP) together with results of the microprobe resolution testing and the elemental analysis performed on typical samples of mineral ore deposits and hyper-accumulating plants regularly measured at ANSTO. The CHIMP focusing and scanning systems are based on the OM-150 Oxford quadrupole triplet and the OM-26 separated scan-coil doublet configurations. A maximum ion rigidity of 38.9 amu-MeV was determined for the following nuclear microprobe configuration: the distance from object aperture to collimating slits of 5890 mm, the working distance of 165 mm and the lens bore diameter of 11 mm. The overall distance from the object to the image plane is 7138 mm. The CHIMP beamline has been tested with the 3 MeV H+ and 6 MeV He2+ ion beams. The settings of the object and collimating apertures have been optimized using the WinTRAX simulation code for calculation of the optimum acceptance settings in order to obtain the highest possible ion current for beam spot sizes of 1 μm and 5 μm. For optimized aperture settings of the CHIMP the beam brightness was measured to be ∼0.9 pA μm-2 mrad-2 for 3 MeV H+ ions, while the brightness of ∼0.4 pA μm-2 mrad-2 was measured for 6 MeV He2+ ions. The smallest beam sizes were achieved using a microbeam with reduced particle rate of 1000 Hz passing through the object slit apertures several micrometers wide. Under these conditions a spatial resolution of ∼0.6 μm × 1.5 μm for 3 MeV H+ and ∼1.8 μm × 1.8 μm for 6 MeV He2+ microbeams in horizontal (and vertical) dimension has been achieved. The beam sizes were verified using STIM imaging on 2000 and 1000 mesh Cu electron microscope grids.

  1. Characterisation of candidate reference materials by PIXE analysis and nuclear microprobe PIXE imaging

    Jaksic, M.; Pastuovic, Z.; Bogdanovic, I.; Tadic, T.

    2002-01-01

    In order to test whether some candidate reference materials show homogeneity that can satisfy quality control of the PIXE technique, six bottles of each of the two Candidate RM's - Lichen (IAEA 338) and Algae (IAEA 413) were tested. Four different tests were performed. First, two pellets from each bottle were prepared and analysed using broad beam (φ = 5 mm) PIXE. Second and third was analysis of homogeneity using scanning focussed beam at the nuclear microprobe. Scans of 50x50 μm 2 and 240x260 μm 2 were performed. Finally, individual grains with composition differing from the rest of the sample, were analysed using PIXE and RBS. (author)

  2. Applications of petrography and electron microprobe analysis to the study of Indian stone sculpture

    Newman, R.

    1992-01-01

    Examples of research on ancient Indian stone artefacts utilizing petrographic examination coupled with qualitative and quantitative electron beam microprobe analysis of specific minerals are described. Types of artefacts discussed include Gandharan schist sculptures, Pala dynasty phyllite and schist objects from eastern India. Hoysala sculptures from Karnataka state (southern India), and sandstone objects from northern India. In spite of the rich history of stone sculpture in the Indian subcontinent, characterization studies to date have been limited in scope, typically involving unprovenanced artefacts. The examples described point to areas in which more extensive research could produce useful information for the provenancing of artefacts. (author)

  3. Laser diffraction analysis of colloidal crystals

    Sogami, Ikuo S.; Shinohara, Tadatomi; Yoshiyama, Tsuyoshi [Kyoto Sangyo Univ., Department of Physics, Kyoto (Japan)

    2001-10-01

    Laser diffraction analysis is made on crystallization in salt-free aqueous suspensions of highly-charged colloidal particles for semi-dilute specimens of concentration 0.1-10.0 vol%. Kossel diffraction patterns which represent faithfully accurate information on lattice symmetries in the suspensions enable us to investigate the time evolution of colloidal crystals. The results show that the crystallization proceeds by way of the following intermediate phase transitions: two-dimensional hcp structure {yields} random layer structure {yields} layer structure with one sliding degree of freedom {yields} stacking disorder structure {yields} stacking structure with multivariant periodicity {yields} fcc twin structure with twin plane (111) {yields} normal fcc structure {yields} bcc twin structure with twin plane (11-bar2) or (1-bar12) {yields} normal bcc structure. For concentrated suspensions (>2 vol %), the phase transition ceases to proceed at the normal fcc structure. (author)

  4. Laser diffraction analysis of colloidal crystals

    Sogami, Ikuo S.; Shinohara, Tadatomi; Yoshiyama, Tsuyoshi

    2001-01-01

    Laser diffraction analysis is made on crystallization in salt-free aqueous suspensions of highly-charged colloidal particles for semi-dilute specimens of concentration 0.1-10.0 vol%. Kossel diffraction patterns which represent faithfully accurate information on lattice symmetries in the suspensions enable us to investigate the time evolution of colloidal crystals. The results show that the crystallization proceeds by way of the following intermediate phase transitions: two-dimensional hcp structure → random layer structure → layer structure with one sliding degree of freedom → stacking disorder structure → stacking structure with multivariant periodicity → fcc twin structure with twin plane (111) → normal fcc structure → bcc twin structure with twin plane (11-bar2) or (1-bar12) → normal bcc structure. For concentrated suspensions (>2 vol %), the phase transition ceases to proceed at the normal fcc structure. (author)

  5. Ion beam analysis - development and application of nuclear reaction analysis methods, in particular at a nuclear microprobe

    Sjoeland, K.A.

    1996-11-01

    This thesis treats the development of Ion Beam Analysis methods, principally for the analysis of light elements at a nuclear microprobe. The light elements in this context are defined as having an atomic number less than approx. 13. The work reported is to a large extent based on multiparameter methods. Several signals are recorded simultaneously, and the data can be effectively analyzed to reveal structures that can not be observed through one-parameter collection. The different techniques are combined in a new set-up at the Lund Nuclear Microprobe. The various detectors for reaction products are arranged in such a way that they can be used for the simultaneous analysis of hydrogen, lithium, boron and fluorine together with traditional PIXE analysis and Scanning Transmission Ion Microscopy as well as photon-tagged Nuclear Reaction Analysis. 48 refs

  6. Sampling and analysis of groundwater colloids. A literature review

    Takala, M.; Manninen, P.

    2006-03-01

    The purpose of this literature study was to give basic information of colloids: their formation, colloid material, sampling and characterisation of groundwater colloids. Colloids are commonly refereed to as particles in the size range of 1 nm to 1000 nm. They are defined as a suspension of solid material in a liquid that does not appear to separate even after a long period of time. Colloids can be formed from a variety of inorganic or organic material. Inorganic colloids in natural groundwaters are formed by physical fragmentation of the host rock or by precipitation. The water chemistry strongly controls the stability of colloids. The amount of colloid particles in a solution tends to decrease with the increasing ionic strength of the solution. Increases in pH and organic material tend to increase the stability of colloids. The mobility of colloids in a porous medium is controlled mainly by groundwater movement, sedimentation, diffusion and interception. Factors controlling sampling artefacts are oxygen diffusion: leads to e.g. calcite precipitation, pumping rates and filtering techniques. Efforts to minimise artefact formation should be taken if the scope of the sampling programme is to study the colloid particles. The colloid phase size distribution can be determined by light scattering systems, laser induced break down or by single particle analysis using SEM micrographs. Elemental compositions can be analysed with EDS spectrometry from single colloid particles. Bulk compositions of the colloid phase can be analysed with e.g. ICP-MS analyser. The results of this study can be used as guidelines for groundwater colloid samplings. Recommendations for future work are listed in the conclusions of this report. (orig.)

  7. Physical aspects of quantitative particles analysis by X-ray fluorescence and electron microprobe techniques

    Markowicz, A.

    1986-01-01

    The aim of this work is to present both physical fundamentals and recent advances in quantitative particles analysis by X-ray fluorescence (XRF) and electron microprobe (EPXMA) techniques. A method of correction for the particle-size effect in XRF analysis is described and theoretically evaluated. New atomic number- and absorption correction procedures in EPXMA of individual particles are proposed. The applicability of these two correction methods is evaluated for a wide range of elemental composition, X-ray energy and sample thickness. Also, a theoretical model for composition and thickness dependence of Bremsstrahlung background generated in multielement bulk specimens as well as thin films and particles are presented and experimantally evaluated. Finally, the limitations and further possible improvements in quantitative particles analysis by XFR and EPXMA are discussed. 109 refs. (author)

  8. Proton microprobe analysis of zinc in skeletal tissues. [Proton induced x-ray emission analysis

    Doty, S B; Jones, K W; Kraner, H W; Shroy, R E; Hanson, A L

    1980-06-01

    A proton microprobe with windowless exit port was used to study zinc distributions in various types of skeletal tissues. The use of an external beam facilitated positioning of the targets for examination of particular points of interest. The proton microprobe is uniquely suited to this work since it combines high sensitivity for zinc determinations in thick samples with good spatial resolution. Measurements on rat and rabbit Achilles tendon showed a significant increase in zinc concentrations as the beam moved from the unmineralized collagen into the mineralized attachment site. Cartilage gave a similar result, with calcified cartilage having a greater zinc level than the articular surface on unmineralized epiphyseal cartilage.

  9. The non-destructive analysis of fluid inclusions in minerals using the proton microprobe

    Ryan, C.G.; Van Achterbergy, E. [Commonwealth Scientific and Industrial Research Organisation (CSIRO), North Ryde, NSW (Australia). Div. of Exploration Geoscience; Heinrich, C.A. [ETH Zentrum, Zurich, (Switzerland). Department Erdwissenschaften; Mernagh, T.P. [Max-Planck-Institut fuer Chemie (Otto-Hahn-Institut), Mainz (Germany); Zaw, K. [Tasmania Univ., Sandy Bay, TAS (Australia)

    1996-12-31

    The study of ore forming fluids trapped as fluid inclusions in minerals is the key to understanding fluid flow paths at the time of ore formation and to predicting the location of ore bodies within large-scale magmatic hydrothermal systems. The large penetration depths and the predictable nature of MeV proton trajectories and X-ray absorption enables reliable modelling of PIXE yields and the development of standardless quantitative analytical methods. This permits quantitative microanalysis of minerals at ppm levels, and more recently has enabled the development of methods for quantitative trace-element imaging and the quantitative, non-destructive analysis of individual fluid inclusions. This paper reports on recent developments in Proton Microprobe techniques with special emphasis on ore systems and fluid inclusion analysis. 6 refs., 2 figs.

  10. The non-destructive analysis of fluid inclusions in minerals using the proton microprobe

    Ryan, C G; Van Achterbergy, E [Commonwealth Scientific and Industrial Research Organisation (CSIRO), North Ryde, NSW (Australia). Div. of Exploration Geoscience; Heinrich, C A [ETH Zentrum, Zurich, (Switzerland). Department Erdwissenschaften; Mernagh, T P [Max-Planck-Institut fuer Chemie (Otto-Hahn-Institut), Mainz (Germany); Zaw, K [Tasmania Univ., Sandy Bay, TAS (Australia)

    1997-12-31

    The study of ore forming fluids trapped as fluid inclusions in minerals is the key to understanding fluid flow paths at the time of ore formation and to predicting the location of ore bodies within large-scale magmatic hydrothermal systems. The large penetration depths and the predictable nature of MeV proton trajectories and X-ray absorption enables reliable modelling of PIXE yields and the development of standardless quantitative analytical methods. This permits quantitative microanalysis of minerals at ppm levels, and more recently has enabled the development of methods for quantitative trace-element imaging and the quantitative, non-destructive analysis of individual fluid inclusions. This paper reports on recent developments in Proton Microprobe techniques with special emphasis on ore systems and fluid inclusion analysis. 6 refs., 2 figs.

  11. Laser microprobe mass spectrometry: Potential and limitations for inorganic and organic micro-analysis. Pt. 1

    Vaeck, I. van; Gijbels, R.

    1990-01-01

    Laser microprobe mass spectrometry (LMMS) employs a highly focused UV laser beam to ionise a microvolume in the order of 1 μm 3 . The ions produced are then mass-separated in a time-of-flight (TOF) or a Fourier Transform (FT) mass spectrometer. TOF LMMS allows element localisation, detailed speciation of inorganic substances and structural information of organic molecules. Quantitation is difficult. This paper focuses on instrumental aspects and inorganic analysis. Organic applications are treated in part II of this series. Selected examples illustrate that TOF LMMS is a valuable tool for the qualitative characterisation of micro-samples. Also, the applicability to the analysis with high spatial resolution is shown. The current technology and the prospects from the recent FTMS development are discussed. (orig.)

  12. Ion channelling analysis of pre-amorphised silicon diodes using a nuclear microprobe

    Thornton, J.; Paus, K.C.

    1988-01-01

    Aligned and random ion channelling analysis was performed on p + n diode structures in silicon, with the Surrey nuclear microprobe. Three different types of diode were investigated, each pre-amorphised by a different ion (Si + , Ge + or Sn + ) before the p + region was formed by BF 2 + implantation. The ion channelling measurements are presented and compared with previously published electrical measurements on these diodes. Relatively large residual disorder and junction leakage currents were found for the Si + pre-amorphised diodes; however, all the diodes were leaky. The results are consistent with dislocation loops within the depletion regions of the diodes causing both the residual disorder and the large leakage currents. Cross-sectional transmission electron microscopy studies support this model. (author)

  13. Elemental analysis of single phytoplankton cells using the Lund nuclear microprobe

    Pallon, Jan; Elfman, Mikael; Kristiansson, Per; Malmqvist, Klas; Graneli, Edna; Sellborn, Anders; Karlsson, Chatarina

    1999-01-01

    The occurrence of annual marine phytoplankton blooms is becoming a global problem. In Europe, the NUTOX project supported by the EC investigates if unbalanced nutrient compositions in the water promote the dominance of harmful phytoplankton species. One of the tasks is the determination of the elemental composition of single phytoplankton cells. This is carried out using the Lund Nuclear Microprobe with a special focus on C, N, P and K. The overall aim is to understand the mechanism leading to toxin production, model it and eventually propose a counteracting method. The preparative method, used to isolate single living cells while reducing their salt environment, is an important part of the analytical procedure. A comparison of light element detection using backscattering from protons and nuclear reaction analysis using deuterons is made

  14. Laser microprobe mass spectrometry: Potential and limitations for inorganic and organic micro-analysis. Pt. 2

    Vaeck, I. van; Gijbels, R.

    1990-01-01

    Laser microprobe mass spectrometry (LMMS) employs a highly focused UV laser beam to ionise a microvolume in the order of 1 μm 3 . The produced ions are then mass-separated in a time-of-flight (TOF) or a Fourier Transform (FT) mass spectrometer. The technique allows element localisation, detailed speciation of inorganic substances and structural information of organic molecules. Inorganic applications are treated in the preceding part. This paper will focus on the organic aspects. Selected examples illustrate that TOF LMMS can achieve structural characterisation of molecules, untractable by conventional mass spectrometric techniques. Applicability to the analysis with high spatial resolution is shown and the need for surface availability of organic target molecules is discussed. The recently developed FT LMMS may fulfil the need for better mass resolution. However, the comparability of FT LMMS results with TOF LMMS data is not yet obvious. (orig.)

  15. Experimental investigations into sample preparation of Alzheimer tissue specimens for nuclear microprobe analysis

    Pinheiro, T [CEC-JRC, Central Bureau for Nuclear Measurements, Geel (Belgium); Tapper, U A.S. [Dept. of Nuclear Physics, Lund Inst. of Science and Tech. (Sweden); Sturesson, K; Brun, A [Div. of Neuropathology, Dept. of Pathology, Lund University Hospital (Sweden)

    1991-03-01

    Nuclear microprobe analysis was applied to the study of elemental distribution in brains sections of patients with a diagnosis of Alzheimer's disease. Stained and nonstained cryosections were studied. The work carried out shows that serious elemental losses follow the sample staining procedure. Major losses occurred in a simple rinse of the tissue section, probably reducing most of the in-vivo gradients, which show that generally very little information can be gained from stained sections. However, in many cases stained sections are compulsory because of the requirement to recognize the area which is to be studied. All the elemental maps obtained for the neurofibrillary deposits indicate a localized concentration for Si and probably also Al, associated with the senile plaque core. Neither of these elements were found in the staining solutions used. The validity of the results is discussed as well as the possible link of Al and/or Si in the development of Alzheimer's desease. (orig.).

  16. Microprobe and SEM Analysis of a Meteorite from the Campo del Cielo Fall

    Cabanillas, E. D.; Palacios, T. A.

    2003-01-01

    Full Text: Meteorites are unique pieces in nature having not only the enigmatic connotations of the unknown but also are the easier obtained samples of the exterior universe. Furthermore they are the unique alloys that suffered modifications done during enormous periods of time in space and in land The Campo del Cielo fall, occurred more than 5000 years ago, gave hundredths of pieces some of them well studied. We have studied one of the minor pieces from the fall and with microprobe and scanning electronic microscopy analysis we determined the composition of Schreibersite and Rhabdite phosphides of iron and nickel. This study was performed to establish relationships between the duration of alloys and the design of disposal of high level and long lived radioactive waste

  17. Nuclear microprobe analysis of muscle biopsies: Applications in pathology and clinic

    Moretto, Ph.; Coquet, M.; Gherardi, R.K.; Stoedzel, P.

    2000-01-01

    The nuclear microprobe analysis of muscle biopsy sections has been recently applied to investigate different muscle disorders. This technique, employed as a complementary examination in the frame of pathological studies, permitted to confirm the diagnosis for a first pathology and to elucidate the cause of a second. In skeletal muscles of a young patient suffering from a slow progressive myopathy, calcium accumulations have been demonstrated in histologically abnormal fibers. These findings have been compared to histopathological characteristics previously described. On the other hand, we have evaluated muscle sections from two patients who presented symptoms of an inflammatory myopathy, a rare pathology that recently emerged in France. The chemical analyses permitted us to highlight local aluminium infiltration in muscles. The hypothesis of an unusual reaction to intramuscular aluminium accumulation has been advanced. These studies demonstrate the capability for ion beam microanalytical techniques to address acute problems in pathology

  18. Nuclear microprobe analysis of serpentine from the mid-Atlantic ridge

    Orberger, Beate; Metrich, Nicole; Mosbah, Michelle; Mevel, Catherine; Fouquet, Yves

    1999-01-01

    At mid-ocean ridges, ultramafic rocks are serpentinized by interaction with seawater-derived fluids. Elements, dissolved in large quantities in seawater, e.g., Na, K, Cl, Br, Ca and Sr, can be, in small amounts, incorporated as traces into the crystal structure of the various serpentine minerals (Mg 3 Si 2 O 5 (OH) 4 ). These trace elements can be used to track the composition of the reacting fluids and to constrain physico-chemical conditions. This paper represents the first application of particle-induced X- and γ-ray emission (PIXE/PIGE) analysis to serpentine using the nuclear microprobe at the Laboratoire Pierre Suee (CEA-CNRS). Three types of serpentine, belonging to two different serpentinization generations, have been analysed in samples collected from the Mid-Atlantic Ridge (14 deg. 45'N/45 deg. W) that exposes serpentinized peridotites on which the Logachev black smoker is placed. The trace elements Cl, F, S, Cu, Zn, Ca, K, Ni, Cr and Mn were detected from several tens to several thousands of ppm. Bromine, As and Sr are close to the detection limit of about 5 ppm. The trace element concentrations and interelement relationships in serpentines vary (a) with the serpentine type and (b) with the geographic location to the black smoker. Chlorine and in part S originated from seawater, whereas Cu, Zn, Ca, K, Ni, Cr and Fe and the major amount of S were mobilized from the unaltered host rock and partitioned between the serpentine and the aqueous solution

  19. Evaluation of the odd-even effect in limits of detection for electron microprobe analysis of natural minerals

    Verma, Surendra P., E-mail: spv@cie.unam.mx [Departamento de Sistemas Energeticos, Centro de Investigacion en Energia, Universidad Nacional Autonoma de Mexico, Priv. Xochicalco s/no., Col Centro, A.P. 34, Temixco, Mor. 62580 (Mexico); Pandarinath, Kailasa [Departamento de Sistemas Energeticos, Centro de Investigacion en Energia, Universidad Nacional Autonoma de Mexico, Priv. Xochicalco s/no., Col Centro, A.P. 34, Temixco, Mor. 62580 (Mexico); Velasco-Tapia, Fernando [Facultad de Ciencias de la Tierra, Universidad Autonoma de Nuevo Leon, Carretera Linares-Cerro Prieto km. 8, Linares, N.L. 67700 (Mexico); Rodriguez-Rios, Rodolfo [Facultad de Ingenieria e Instituto de Geologia, Universidad Autonoma de San Luis Potosi, Av. Dr. Manuel Nava No. 8, Zona Universitaria, San Luis Potosi, S.L.P. 78240 (Mexico)

    2009-04-13

    Limit of detection (LOD), being a fundamental quality parameter for analytical techniques, has been recently investigated and a systematic behavior has been observed for most odd-even element pairs for many techniques. However, to the best of our knowledge very few LOD data are available in published literature for electron microprobe analysis; these consist of three papers, two being on rare-earth elements and the third covering a large number of elements of atomic number between 21 and 92. These data confirm the systematic behavior of LODs for many odd-even pairs. To initiate to full this gap, we determined LODs for several major rock-forming chemical elements from Na to Fe with atomic numbers between 11 and 26, during the microprobe analysis of common minerals (olivine, plagioclase, pyroxene, amphibole, quartz, and opaques) in volcanic rocks. The odd-even effect of nuclear stability seems to be present in LOD data for most odd-even pairs investigated. Nevertheless, the experimental strategy concerning the reference materials, calibration procedure, and blank measurements, should be substantially modified to better evaluate the systematic behavior of LOD values in microprobe analysis.

  20. Evaluation of the odd-even effect in limits of detection for electron microprobe analysis of natural minerals

    Verma, Surendra P.; Pandarinath, Kailasa; Velasco-Tapia, Fernando; Rodriguez-Rios, Rodolfo

    2009-01-01

    Limit of detection (LOD), being a fundamental quality parameter for analytical techniques, has been recently investigated and a systematic behavior has been observed for most odd-even element pairs for many techniques. However, to the best of our knowledge very few LOD data are available in published literature for electron microprobe analysis; these consist of three papers, two being on rare-earth elements and the third covering a large number of elements of atomic number between 21 and 92. These data confirm the systematic behavior of LODs for many odd-even pairs. To initiate to full this gap, we determined LODs for several major rock-forming chemical elements from Na to Fe with atomic numbers between 11 and 26, during the microprobe analysis of common minerals (olivine, plagioclase, pyroxene, amphibole, quartz, and opaques) in volcanic rocks. The odd-even effect of nuclear stability seems to be present in LOD data for most odd-even pairs investigated. Nevertheless, the experimental strategy concerning the reference materials, calibration procedure, and blank measurements, should be substantially modified to better evaluate the systematic behavior of LOD values in microprobe analysis.

  1. Application of PIXE analysis to environmental samples stable element distribution in sea algae by scanning microprobe analysis

    Ishikawa, M.; Kitao, K.; Imaseki, H.; Ishii, T.; Uchida, S.

    1984-01-01

    The resolution of a 33+-3 μm microprobe focussed with quadrupole doublet installed at the 3 MV Van de Graaff of the National Institute of Radiological Sciences, Japan, was used for the present analysis. Brown algae, Hizikia fusiforme was the sample target bombarded with a 2 MeV proton beam collimated mechanically into a rectangular image of 100 μm x 700 μm. Scanning across the sample target prepared into a longitudinal section from the caulis of the algae provided the following observations. More than 12 elements such as Al, Si, P, Cl, Ca, Mn, Fe, Cu, Zn, As, Br and Sr were determined simultaneously, together with their distributional information across the diameter. In the medullary layer, Mn and Zn were specific in their accumulation, while the deposition of Fe, Cu, As and Br were observed to be high in the epithelial layer, especially Fe and Cu which were found on the surface, where they contacted ambient sea water, but no significant change in pattern was indicated for such elements as Al, P and Cl. The PIXE microprobe analysis was, therefore, effective in its detectability for elements below a few ppm level, resultantly providing further possibilities for collecting information from bio-medical and environmental samples on trace characterization of elements. (author)

  2. Nuclear microprobe analysis and source apportionment of individual atmospheric aerosol particles

    Artaxo, P.; Rabello, M.L.C.; Watt, F.; Grime, G.; Swietlicki, E.

    1993-01-01

    In atmospheric aerosol reserach, one key issue is to determine the sources of the airborne particles. Bulk PIXE analysis coupled with receptor modeling provides a useful, but limited view of the aerosol sources influencing one particular site or sample. The scanning nuclear microprobe (SNM) technique is a microanalytical technique that gives unique information on individual aerosol particles. In the SNM analyses a 1.0 μm size 2.4 MeV proton beam from the Oxford SNM was used. The trace elements with Z>11 were measured by the particle induced X-ray emission (PIXE) method with detection limits in the 1-10 ppm range. Carbon, nitrogen and oxygen are measured simultaneously using Rutherford backscattering spectrometry (RBS). Atmospheric aerosol particles were collected at the Brazilian Antarctic Station and at biomass burning sites in the Amazon basin tropical rain forest in Brazil. In the Antarctic samples, the sea-salt aerosol particles were clearly predominating, with NaCl and CaSO 4 as major compounds with several trace elements as Al, Si, P, K, Mn, Fe, Ni, Cu, Zn, Br, Sr, and Pb. Factor analysis of the elemental data showed the presence of four components: 1) Soil dust particles; 2) NaCl particles; 3) CaSO 4 with Sr; and 4) Br and Mg. Strontium, observed at 20-100 ppm levels, was always present in the CaSO 4 particles. The hierarchical cluster procedure gave results similar to the ones obtained through factor analysis. For the tropical rain forest biomass burning aerosol emissions, biogenic particles with a high organic content dominate the particle population, while K, P, Ca, Mg, Zn, and Si are the dominant elements. Zinc at 10-200 ppm is present in biogenic particles rich in P and K. The quantitative aspects and excellent detection limits make SNM analysis of individual aerosol particles a very powerful analytical tool. (orig.)

  3. Ion microprobes

    Coles, J.N.; Long, J.V.P.

    1977-01-01

    An ion microprobe is described that has an ion extraction arrangement comprising two separate paths for ions and electrons diverging from a common point. A cone shaped or pyramidal guard electrode surrounds each path the apex angles being equal and coinciding with the said point. The guard electrodes are positioned to lie tangentially to each other and to a planar surface including the said point. An aperture is provided for the two paths at the apexes of both guard electrodes, and electrical connections between the guard electrodes enable the same potential to be applied to both guard electrodes. Means are provided for generating oppositely polarised electric fields within the guard electrodes, together with means for causing a focused ion beam to strike the common point without suffering astigmatism. The means for causing a focused ion beam to strike the said point includes an ion gun for directing an ion beam along one of the paths and means to provide an axial accelerating field there along. Optical viewing means are also provided. Existing designs enable only ions or electrons, but not both, to be extracted at any one time. (U.K.)

  4. Nuclear microprobe analysis of serpentine from the mid-Atlantic ridge

    Orberger, Beate E-mail: orberger@geol.u-psud.fr; Metrich, Nicole; Mosbah, Michelle E-mail: mosbah@drecam.cea.fr; Mevel, Catherine; Fouquet, Yves

    1999-09-02

    At mid-ocean ridges, ultramafic rocks are serpentinized by interaction with seawater-derived fluids. Elements, dissolved in large quantities in seawater, e.g., Na, K, Cl, Br, Ca and Sr, can be, in small amounts, incorporated as traces into the crystal structure of the various serpentine minerals (Mg{sub 3}Si{sub 2}O{sub 5}(OH){sub 4}). These trace elements can be used to track the composition of the reacting fluids and to constrain physico-chemical conditions. This paper represents the first application of particle-induced X- and {gamma}-ray emission (PIXE/PIGE) analysis to serpentine using the nuclear microprobe at the Laboratoire Pierre Suee (CEA-CNRS). Three types of serpentine, belonging to two different serpentinization generations, have been analysed in samples collected from the Mid-Atlantic Ridge (14 deg. 45'N/45 deg. W) that exposes serpentinized peridotites on which the Logachev black smoker is placed. The trace elements Cl, F, S, Cu, Zn, Ca, K, Ni, Cr and Mn were detected from several tens to several thousands of ppm. Bromine, As and Sr are close to the detection limit of about 5 ppm. The trace element concentrations and interelement relationships in serpentines vary (a) with the serpentine type and (b) with the geographic location to the black smoker. Chlorine and in part S originated from seawater, whereas Cu, Zn, Ca, K, Ni, Cr and Fe and the major amount of S were mobilized from the unaltered host rock and partitioned between the serpentine and the aqueous solution.

  5. Rapid rock analysis and microprobe scanning of dermatological material using proton-induced x-ray and γ-ray emission

    Carlsson, L.E.

    1983-01-01

    The dissertation report comprises 6 articles that have or will appear in open literature. The use of PIXE and PIGE analysis techniques on geological materials, and also on drill cores, is discussed. The accuracy of the methods have been tested on standards. The effect of sample thickness has been studied. A proton microprobe has been compared with an electron microprobe on human skin sections. Both probes give highly reproducible results, but a small systematic deviation between the probes is found. (author)

  6. Trace elemental analysis of bituminous coals using the Heidelberg proton microprobe

    Chen, J R; Kneis, H; Martin, B; Nobiling, R; Traxel, K [Max-Planck-Institut fuer Kernphysik, Heidelberg (Germany, F.R.); Heidelberg Univ. (Germany, F.R.). Physikalisches Inst.); Chao, E C.T.; Minkin, J A [Geological Survey, Reston, VA (USA)

    1981-03-01

    Trace elements in coal can occur as components of either the organic constituents (macerals) or the inorganic constituents (minerals). Studies of the concentrations and distribution of the trace elements are vital to understanding the geochemical milieu in which the coal was formed and in evaluating the attempts to recover rare but technologically valuable metals. In addition, information on the trace element concentrations is important in predicting the environmental impact of burning particular coals, as many countries move toward greater utilization of coal reserves for energy production. Traditionally, the optical and the electron microscopes and more recently the electron microprobe have been used in studying the components of coal. The proton-induced X-ray emission (PIXE) microprobe offers a new complementary approach with an order of magnitude or more better minimum detection limit. We present the first measurements with a PIXE microprobe of the trace element concentrations of bituminous coal samples. Elemental analyses of the coal macerals-vitrinite, exinite, and inertinite - are discussed for three coal samples from the Eastern U.S.A., three samples from the Western U.S.A., and one sample from the Peoples Republic of China.

  7. Explorative analysis of microbes, colloids and gases

    Hallbeck, Lotta; Pedersen, Karsten (Microbial Analytics Sweden AB, Goeteborg (Sweden))

    2008-08-15

    The overall objectives of the hydrogeochemical description for Forsmark are to establish a detailed understanding of the hydrogeochemical conditions at the site and to develop models that fulfil the needs identified by the safety assessment groups during the site investigation phase. Issues of concern to safety assessment are radionuclide transport and technical barrier behaviour, both of which are dependent on the chemistry of groundwater and pore water and their evolution with time. In this report, part of the final hydrogeochemical evaluation work of the site investigation at the Forsmark site, is presented. The work was conducted by SKB's hydrogeochemical project group, ChemNet, which consists of independent consultants and Univ. researchers with expertise in geochemistry, hydrochemistry, hydrogeochemistry, microbiology, geomicrobiology, analytical chemistry etc. The resulting site descriptive model version, mainly based on 2.2 data and complementary 2.3 data, was carried out during September 2006 to December 2007. This report focuses on microbiology, colloids and gases: - Microbes (Chapter 1): Several methods must be used to characterize active microbial communities in groundwater. Microbial parameters of interest are the total number of cells (TNC) and the presence of various metabolic groups of microorganisms. Different microbial groups influence the environment in different ways, depending on what metabolic group is dominant. Typically, the following redox couples are utilized by bacteria in granitic groundwater: H{sub 2}O/O{sub 2}, NO{sub 3}-/N{sub 2}, Mn2+/Mn(IV), Fe2+/Fe(III), S2-/SO{sub 4}2-, CH{sub 4}/CO{sub 2}, CH{sub 3}COOH/CO{sub 2}, and H{sub 2}/H+. The data will indicate the activity of specific microbial populations at particular sites and how they may affect the geochemistry. - Colloids (Chapter 2): Particles in the size range from 1 to 1x10-3 mum are regarded as colloids. Their small size prohibits them from settling, which gives them the

  8. Explorative analysis of microbes, colloids and gases

    Hallbeck, Lotta; Pedersen, Karsten

    2008-08-01

    The overall objectives of the hydrogeochemical description for Forsmark are to establish a detailed understanding of the hydrogeochemical conditions at the site and to develop models that fulfil the needs identified by the safety assessment groups during the site investigation phase. Issues of concern to safety assessment are radionuclide transport and technical barrier behaviour, both of which are dependent on the chemistry of groundwater and pore water and their evolution with time. In this report, part of the final hydrogeochemical evaluation work of the site investigation at the Forsmark site, is presented. The work was conducted by SKB's hydrogeochemical project group, ChemNet, which consists of independent consultants and Univ. researchers with expertise in geochemistry, hydrochemistry, hydrogeochemistry, microbiology, geomicrobiology, analytical chemistry etc. The resulting site descriptive model version, mainly based on 2.2 data and complementary 2.3 data, was carried out during September 2006 to December 2007. This report focuses on microbiology, colloids and gases: - Microbes (Chapter 1): Several methods must be used to characterize active microbial communities in groundwater. Microbial parameters of interest are the total number of cells (TNC) and the presence of various metabolic groups of microorganisms. Different microbial groups influence the environment in different ways, depending on what metabolic group is dominant. Typically, the following redox couples are utilized by bacteria in granitic groundwater: H 2 O/O 2 , NO 3 - /N 2 , Mn 2+ /Mn(IV), Fe 2+ /Fe(III), S 2- /SO 4 2- , CH 4 /CO 2 , CH 3 COOH/CO 2 , and H 2 /H + . The data will indicate the activity of specific microbial populations at particular sites and how they may affect the geochemistry. - Colloids (Chapter 2): Particles in the size range from 1 to 1x10 -3 μm are regarded as colloids. Their small size prohibits them from settling, which gives them the potential to transport

  9. Use of a synchrotron radiation x-ray microprobe for elemental analysis at the National Synchrotron Light Source

    Gordon, B.M.

    1980-01-01

    The National Synchrotron Light Source (NSLS) is a facility consisting of a 700 MeV and a 2.5 GeV electron storage ring and dedicated to providing synchrotron radiation in the energy range from the vacuum ultraviolet to high energy x rays. Some of the properties of synchrotron radiation that contribute to its usefulness for x-ray fluorescence are: a continuous, tunable energy spectrum, strong collimation in the horizontal plane, high polarization in the storage ring plane, and relatively low energy deposition. The highest priority is for the development of an x-ray microprobe beam line capable of trace analysis in the parts per million range with spatial resolution as low as one micrometer. An eventual capability for bulk sample analysis is also planned with sensitivities in the more favorable cases beings low as 50 parts per billion in dry biological tissue. The microprobe technique has application to a variety of fields including the geological, medical, materials and environmental sciences. Examples of investigations include multielemental trace analysis across grain boundaries for the study of diffusion and cooling processes in geological and materials sciences samples; in leukocytes and other types of individual cells for studying the relationship between trace element concentrations and disease or nutrition; and in individual particles in air pollution samples

  10. Cometary and interstellar dust grains - Analysis by ion microprobe mass spectrometry and other techniques

    Zinner, Ernst

    1991-01-01

    A survey of microanalytical measurements on interplanetary dust particles (IDPs) and interstellar dust grains from primitive meteorites is presented. Ion-microprobe mass spectrometry with its capability to determine isotopic compositions of many elements on a micron spatial scale has played a special role. Examples are measurements of H, N, and O isotopes and refractory trace elements in IDPs; C, N, Mg, and Si isotopes in interstellar SiC grains; and C and N isotopes and H, N, Al, and Si concentrations in interstellar graphite grains.

  11. Microprobe analysis of PuO2--UO2 nuclear fuel

    Clark, W.I.; Rasmussen, D.E.; Carlson, R.L.; Highley, D.M.

    1977-01-01

    For the preirradiation characterization of FFTF UO 2 --PuO 2 fuel, a program was developed to determine the preirradiation porosity, grain structure, and microcomposition of the fuel. Two computer programs, MITRAN and MERIT, were developed to evaluate the homogeneity of the fuel. These programs use elemental composition data generated by the electron microprobe. MITRAN determines information on the size and frequency of individual regions, whereas MERIT provides an index of the thermal performance of the fuel and calculated statistical data for comparison to other fuel batches

  12. Ion microprobe mass analysis of plagioclase from 'non-mare' lunar samples

    Meyer, C., Jr.; Anderson, D. H.; Bradley, J. G.

    1974-01-01

    The ion microprobe was used to measure the composition and distribution of trace elements in lunar plagioclase, and these analyses are used as criteria in determining the possible origins of some nonmare lunar samples. The Apollo 16 samples with metaclastic texture and high-bulk trace-element contents contain plagioclase clasts with extremely low trace-element contents. These plagioclase inclusions represent unequilibrated relicts of anorthositic, noritic, or troctolitic rocks that have been intermixed as a rock flour into the KREEP-rich matrix of these samples. All of the plagioclase-rich inclusions which were analyzed in the KREEP-rich Apollo 14 breccias were found to be rich in trace elements. This does not seem to be consistent with the interpretation that the Apollo 14 samples represent a pre-Imbrium regolith, because such an ancient regolith should have contained many plagioclase clasts with low trace-element contents more typical of plagioclase from the pre-Imbrium crust. Ion-microprobe analyses for Ba and Sr in large plagioclase phenocrysts in 14310 and 68415 are consistent with the bulk compositions of these rocks and with the known distribution coefficients for these elements. The distribution coefficient for Li (basaltic liquid/plagioclase) was measured to be about 2.

  13. Automated electron microprobe

    Thompson, K.A.; Walker, L.R.

    1986-01-01

    The Plant Laboratory at the Oak Ridge Y-12 Plant has recently obtained a Cameca MBX electron microprobe with a Tracor Northern TN5500 automation system. This allows full stage and spectrometer automation and digital beam control. The capabilities of the system include qualitative and quantitative elemental microanalysis for all elements above and including boron in atomic number, high- and low-magnification imaging and processing, elemental mapping and enhancement, and particle size, shape, and composition analyses. Very low magnification, quantitative elemental mapping using stage control (which is of particular interest) has been accomplished along with automated size, shape, and composition analysis over a large relative area

  14. Analysis report for WIPP colloid model constraints and performance assessment parameters

    Mariner, Paul E.; Sassani, David Carl

    2014-03-01

    An analysis of the Waste Isolation Pilot Plant (WIPP) colloid model constraints and parameter values was performed. The focus of this work was primarily on intrinsic colloids, mineral fragment colloids, and humic substance colloids, with a lesser focus on microbial colloids. Comments by the US Environmental Protection Agency (EPA) concerning intrinsic Th(IV) colloids and Mg-Cl-OH mineral fragment colloids were addressed in detail, assumptions and data used to constrain colloid model calculations were evaluated, and inconsistencies between data and model parameter values were identified. This work resulted in a list of specific conclusions regarding model integrity, model conservatism, and opportunities for improvement related to each of the four colloid types included in the WIPP performance assessment.

  15. Planktonic foraminiferal oxygen isotope analysis by ion microprobe technique suggests warm tropical sea surface temperatures during the Early Paleogene

    Kozdon, Reinhard; Kelly, D. Clay; Kita, Noriko T.; Fournelle, John H.; Valley, John W.

    2011-09-01

    Cool tropical sea surface temperatures (SSTs) are reported for warm Paleogene greenhouse climates based on the δ18O of planktonic foraminiferal tests. These results are difficult to reconcile with models of greenhouse gas-forced climate. It has been suggested that this "cool tropics paradox" arises from postdepositional alteration of foraminiferal calcite, yielding erroneously high δ18O values. Recrystallization of foraminiferal tests is cryptic and difficult to quantify, and the compilation of robust δ18O records from moderately altered material remains challenging. Scanning electron microscopy of planktonic foraminiferal chamber-wall cross sections reveals that the basal area of muricae, pustular outgrowths on the chamber walls of species belonging to the genus Morozovella, contain no mural pores and may be less susceptible to postdepositional alteration. We analyzed the δ18O in muricae bases of morozovellids from the central Pacific (Ocean Drilling Program Site 865) by ion microprobe using 10 μm pits with an analytical reproducibility of ±0.34‰ (2 standard deviations). In situ measurements of δ18O in these domains yield consistently lower values than those published for conventional multispecimen analyses. Assuming that the original δ18O is largely preserved in the basal areas of muricae, this new δ18O record indicates Early Paleogene (˜49-56 Ma) tropical SSTs in the central Pacific were 4°-8°C higher than inferred from the previously published δ18O record and that SSTs reached at least ˜33°C during the Paleocene-Eocene thermal maximum. This study demonstrates the utility of ion microprobe analysis for generating more reliable paleoclimate records from moderately altered foraminiferal tests preserved in deep-sea sediments.

  16. Elemental analysis of some West Malaysian limestones using neutron activation, delayed neutron and electron microprobe analysis

    Amin, Y.M.; Kamaluddin, B.; Mahat, R.H.

    1990-01-01

    Limestone stratigraphy in Malaysia has been and is dependent almost entirely in palaeontology. However fossil localities are sporadic and as such a new fossil discovery mean the necessity for a complete re-appraisal of the stratigraphy. The almost complete dependence upon palaeontology results from the difficulties of stratigraphy correlation of isolated outcrops, from the cover of tropical vegetation and from the often complex folding and faulting which has been imposed on the geosyn-clinical rocks by the Indonesian-Thai-Malayan orogeny. So by studying the elemental composition of limestones accurately, we would be able to correlate outcrops and other stratigraphic samples independent of fossil finds. The use of delayed neutron analysis would also determine the concentration of uranium and thorium accurately. This study, in conjunction with thermoluminescence and fission track studies, would able us to date the age of the limestones

  17. Positron annihilation microprobe

    Canter, K F [Brandeis Univ., Waltham, MA (United States)

    1997-03-01

    Advances in positron annihilation microprobe development are reviewed. The present resolution achievable is 3 {mu}m. The ultimate resolution is expected to be 0.1 {mu}m which will enable the positron microprobe to be a valuable tool in the development of 0.1 {mu}m scale electronic devices in the future. (author)

  18. Nuclear scanning microprobe: state of the art, applications and progress trends

    Ponomarev, A.G.

    2011-01-01

    The physical principles of nuclear scanning microprobe are considered. The analysis of state of the art of the microprobe setup from point of view of its spatial resolution and sensitivity of microanalysis techniques is given. The regions of nuclear microprobe applications are reviewed. The ways of spatial resolution and data acquisition system improvement under consideration of microprobe setup progress trends are considered. (authors)

  19. Microscopic and microprobe analysis of fine roots in healthy and declining spruce (Picea abies (L. ) Karst. ) from different sites

    Stienen, H; Bauch, J; Barckhausen, R; Schaub, H

    1984-09-01

    In order to contribute to the identification of primary causes of the spruce decline - evident in many regions of the Federal Republic of Germany - fine roots of 30 trees from altogether 14 healthy and damage forest locations were investigated microscopically, anatomically, histometrically and by cellular microprobe analysis. In addition, fine roots of young plants grown in hydroponic cultures at different pH levels and Al input were studied. Fine roots of declining trees developed cortex cells with a reduced diameter and at the same time thicker cell walls; in addition accessory compounds were accumulated in this presumably protective tissue. Tannins were deposited in the parenchyma of the vascular cylinder of fine roots from declining trees, and many pit membranes of the primary xylem often did not differentiate fully. The X-ray energy-dispersive analysis of individual cells revealed, in particular, an insufficient uptake of Ca and Mg in the fine roots of declining trees. Compared with healthy trees, the concentration of aluminium increased in the cortex of the fine roots; this, in turn, had an antagonistic effect on the uptake of Ca and Mg. Moreover, the concentration of iron and sulphur increased in the fine roots of declining trees. This evidence of alterations and damages in the fine roots of damaged spruce indicates that, besides the direct detrimental impact on the needles through the atmosphere serious damage is inflicted also indirectly through the soil.

  20. PIXE and light element analysis (C,N) in glass inclusions trapped in meteorites with the nuclear microprobe

    Varela, M.E.; Mosbah, M.; Metrich, N.; Duraud, J.P.; Kurat, G.

    1999-01-01

    Proton-induced X-ray emission (PIXE) and light element analysis have been performed with the nuclear microprobe at the Laboratoire Pierre Suee (Saclay-France) in glass inclusions of the carbonaceous chondrites: Allende, Kaba and Renazzo, and in the achondrite meteorite: Chassigny. Carbon contents in olivine of chondrules are below the nuclear reactions analysis (NRA) detection limit, however, glasses from glass inclusions hosted by these grains, contain an appreciable and highly variable quantities of carbon (200-1600 ppm). This could indicate variable amounts of C trapped during glass inclusion formation. On the other hand, nitrogen is present in highly variable amounts in glasses of both, chondrites and achondrites minerals. Its abundance, correlated with depth from the section surface which suggests loss of N during analyses and therefore the possible existence of a very mobile (volatile?) species. A chondritic Rb/Sr and K/Rb ratio obtained by PIXE analyses in the glass-bearing inclusions of the Chassigny meteorite points towards a primitive source for the glass precursor of Chassigny inclusions

  1. Distribution of elements in rat peripheral axons and nerve cell bodies determined by x-ray microprobe analysis

    LoPachin, R.M. Jr.; Lowery, J.; Eichberg, J.; Kirkpatrick, J.B.; Cartwright, J. Jr.; Saubermann, A.J.

    1988-09-01

    X-ray microprobe analysis was used to determine concentrations (millimoles of element per kilogram dry weight) of Na, P, Cl, K, and Ca in cellular compartments of frozen, unfixed sections of rat sciatic and tibial nerves and dorsal root ganglion (DRG). Five compartments were examined in peripheral nerve (axoplasm, mitochondria, myelin, extraaxonal space, and Schwann cell cytoplasm), and four were analyzed in DRG nerve cell bodies (cytoplasm, mitochondria, nucleus, and nucleolus). Each morphological compartment exhibited characteristic concentrations of elements. The extraaxonal space contained high concentrations of Na, Cl, and Ca, whereas intraaxonal compartments exhibited lower concentrations of these elements but relatively high K contents. Nerve axoplasm and axonal mitochondria had similar elemental profiles, and both compartments displayed proximodistal gradients of decreasing levels of K, Cl, and, to some extent, Na. Myelin had a selectively high P concentration with low levels of other elements. The elemental concentrations of Schwann cell cytoplasm and DRG were similar, but both were different from that of axoplasm, in that K and Cl were markedly lower whereas P was higher. DRG cell nuclei contained substantially higher K levels than cytoplasm. The subcellular distribution of elements was clearly shown by color-coded images generated by computer-directed digital x-ray imaging. The results of this study demonstrate characteristic elemental distributions for each anatomical compartment, which doubtless reflect nerve cell structure and function.

  2. PROTON MICROPROBE ANALYSIS OF TRACE-ELEMENT VARIATIONS IN VITRINITES IN THE SAME AND DIFFERENT COAL BEDS.

    Minkin, J.A.; Chao, E.C.T.; Blank, Herma; Dulong, F.T.

    1987-01-01

    The PIXE (proton-induced X-ray emission) microprobe can be used for nondestructive, in-situ analyses of areas as small as those analyzed by the electron microprobe, and has a sensitivity of detection as much as two orders of magnitude better than the electron microprobe. Preliminary studies demonstrated that PIXE provides a capability for quantitative determination of elemental concentrations in individual coal maceral grains with a detection limit of 1-10 ppm for most elements analyzed. Encouraged by the earlier results, we carried out the analyses reported below to examine trace element variations laterally (over a km range) as well as vertically (cm to m) in the I and J coal beds in the Upper Cretaceous Ferron Sandstone Member of the Mancos Shale in central Utah, and to compare the data with the data from two samples of eastern coals of Pennsylvanian age.

  3. In situ titanium dioxide nanoparticles quantitative microscopy in cells and in C. elegans using nuclear microprobe analysis

    Le Trequesser, Quentin [Université de Bordeaux, CENBG, Chemin du solarium, 33175 Gradignan (France); CNRS, UMR 5797, CENBG, Chemin du solarium, 33175 Gradignan (France); CNRS, Université de Bordeaux, ICMCB, 87 avenue du Dr. A. Schweitzer, Pessac F-33608 (France); Saez, Gladys; Devès, Guillaume; Michelet, Claire; Barberet, Philippe [Université de Bordeaux, CENBG, Chemin du solarium, 33175 Gradignan (France); CNRS, UMR 5797, CENBG, Chemin du solarium, 33175 Gradignan (France); Delville, Marie-Hélène [CNRS, Université de Bordeaux, ICMCB, 87 avenue du Dr. A. Schweitzer, Pessac F-33608 (France); Seznec, Hervé, E-mail: herve.seznec@cenbg.in2p3.fr [Université de Bordeaux, CENBG, Chemin du solarium, 33175 Gradignan (France); CNRS, UMR 5797, CENBG, Chemin du solarium, 33175 Gradignan (France)

    2014-12-15

    Detecting and tracking nanomaterials in biological systems is challenging and essential to understand the possible interactions with the living. In this context, in situ analyses were conducted on human skin cells and a multicellular organism (Caenorhabditiselegans) exposed to titanium dioxide nanoparticles (TiO{sub 2} NPs) using nuclear microprobe. Coupled to conventional methods, nuclear microprobe was found to be suitable for accurate description of chemical structure of biological systems and also for detection of native TiO{sub 2} NPs. The method presented herein opens the field to NPs exposure effects analyses and more generally to toxicological analyses assisted by nuclear microprobe. This method will show applications in key research areas where in situ imaging of chemical elements is essential.

  4. Use of electron microprobe x-ray analysis for determination of low calcium concentrations across leaves deficient in calcium

    Barta, D. J.; Tibbitts, T. W.

    1991-01-01

    An electron microprobe with wavelength-dispersive x-ray spectrometry (WDS) was found to be useful for the determination of Ca concentrations in leaf tissue deficient in Ca. WDS effectively detected Ca concentrations as low as 0.2 mg/g dry wt in the presence of high levels of K and Mg (120 and 50 mg/g dry wt, respectively). Leaf specimens were prepared for analysis by quick-freezing in liquid nitrogen and freeze-drying at -20 degrees C to maintain elemental integrity within the tissue. Because dry material was analyzed, sample preparation was simple and samples could be stored for long periods before analysis. A large beam diameter of 50 gm was used to minimize tissue damage under the beam and analyze mineral concentrations within several cells at one time. Beam penetration was between 50 and 55 microns, approximately one-third of the thickness of the leaf. For analysis of concentrations in interveinal areas, analyses directed into the abaxial epidermis were found most useful. However, because of limited beam penetration, analyses of veinal areas would require use of cross sections [correction of crosssections]. Solid mineral standards were used for instrument standardization. To prevent measurement errors resulting from differences between the matrix of the mineral standards and the analyzed tissue, concentrations in leaves were corrected using gelatin standards prepared and analyzed under the same conditions. WDS was found to be useful for documenting that very low Ca levels occur in specific areas of lettuce leaves exhibiting the Ca deficiency injury termed tipburn.

  5. Trace element analysis in geochemistry using a nuclear microprobe. Ionoluminescence and particle induced X-ray emission

    Homman, P.

    1994-01-01

    In PIXE analysis of geological specimens based on X-ray detection with Si(Li) detectors, effects of detector tailing, pulse pileup, and gamma-ray production are pronounced. In this work the tailing effect has been addressed through characterization of the response function of a Si(Li) detector using an absorber technique. The pileup interval, in the pulse forming electronics of a PIXE detection system, has been improved to 100 ns X-ray energies above 8 keV by means of pulse shape analysis. Pulses due to tailing effects were also isolated but no major improvement was obtained. A means of reducing the increased background in the PIXE spectrum due to Compton scattering of high energetic gamma-rays in the Si(Li) crystal has been investigated by installation of an anti-Compton shield consisting of an organic scintillator mounted inside the detector cryostat and read out by a photomultiplier. Ionoluminescence, a new analytical technique for the nuclear microprobe, has shown to be a technique that can be employed as a fast diagnostic tool in imaging applications. The technique is based on analysis of the light that often can be observed when an ion beam impinges on a geological specimen. This light, luminescence, can often be associated with impurities in the crystal lattice or other structural defects. It can therefore be employed for revealing some chemical information about the specimens in contradiction to PIXE which is rather insensitive to chemical variations. The potential of the method is demonstrated and discussed both as an imaging tool and for spectroscopic studies. 19 refs, 10 figs

  6. Quantitative analysis of chemical elements in single cells using nuclear microprobe and nano-probe

    Deves, Guillaume

    2010-01-01

    The study of the role of trace elements at cellular level requires the use of state-of-the-art analytical tools that could achieve enough sensitivity and spatial resolution. We developed a new methodology for the accurate quantification of chemical element distribution in single cells based on a combination of ion beam analysis techniques STIM, PIXE and RBS. The quantification procedure relies on the development of a STIM data analysis software (Paparamborde). Validity of this methodology and limits are discussed here. The method allows the quantification of trace elements (μg/g) with a 19.8 % uncertainty in cellular compartments with mass below 0.1 ng. The main limit of the method lies in the poor number of samples that can be analyzed, due to long irradiation times required and limited access to ion beam analysis facilities. This is the reason why we developed a database for cellular chemical composition capitalization (BDC4). BDC4 has been designed in order to use cellular chemical composition as a tracer for biological activities and is expected to provide in the future reference chemical compositions for any cellular type or compartment. Application of the STIM-PIXE-RBS methodology to the study of nuclear toxicology of cobalt compounds is presented here showing that STIM analysis is absolutely needed when organic mass loss appears during PIXE-RBS irradiation. (author)

  7. Quantitative X-ray fluorescence analysis at the ESRF ID18F microprobe

    Vekemans, B; Somogyi, A; Drakopoulos, M; Kempenaers, L; Simionovici, A; Adams, F

    2003-01-01

    The new ID18F end-station at the European synchrotron radiation facility (ESRF) in Grenoble (France) is dedicated to sensitive and accurate quantitative micro-X-ray fluorescence (XRF) analysis at the ppm level with accuracy better than 10% for elements with atomic numbers above 18. For accurate quantitative analysis, given a high level of instrumental stability, major steps are the extraction and conversion of experimental X-ray line intensities into elemental concentrations. For this purpose a two-step quantification approach was adopted. In the first step, the collected XRF spectra are deconvoluted on the basis of a non-linear least-squares fitting algorithm (AXIL). The extracted characteristic line intensities are then used as input for a detailed Monte Carlo (MC) simulation code dedicated to XRF spectroscopy taking into account specific experimental conditions (excitation/detection) as well as sample characteristics (absorption and enhancement effects, sample topology, heterogeneity etc.). The iterative u...

  8. X-ray microprobe analysis of platelets. Principles, methods and review of the literature.

    Yarom, R

    1983-01-01

    Platelets are well suited to X-ray microanalysis as there is no need for chemical fixation or sectioning, and the concentrations of calcium and phosphorus are above 10(-3). The principles of the technique, the methods of specimen preparation, instrumental conditions during analysis and ways of quantitation are described. This is followed by a review of published reports and a brief summary of the author's own work in the field.

  9. Oxidation kinetics and auger microprobe analysis of some oxidized zirconium alloys

    Ploc, R.A.

    1989-01-01

    Oxidation kinetics at 300 o C in dry oxygen of 0.5 wt% binary alloys of iron, nickel, and chromium in zirconium were determined for several surface preparations. Further, chemical profiles of the oxides as they existed on the matrix and on the precipitates were obtained by sputtering and Auger electron analysis. The appearance of 'breakaway' oxidation was controlled by the surface finish of the alloy, a variable that could be used to eliminate the phenomenon for all alloys except the Zr/Ni binary, which required β-quenching to accomplish the same purpose. (author)

  10. Study of metal bioaccumulation by nuclear microprobe analysis of algae fossils and living algae cells

    Guo, P.; Wang, J.; Li, X.; Zhu, J.; Reinert, T.; Heitmann, J.; Spemann, D.; Vogt, J.; Flagmeyer, R.-H.; Butz, T.

    2000-01-01

    Microscopic ion-beam analysis of palaeo-algae fossils and living green algae cells have been performed to study the metal bioaccumulation processes. The algae fossils, both single cellular and multicellular, are from the late Neoproterozonic (570 million years ago) ocean and perfectly preserved within a phosphorite formation. The biosorption of the rare earth element ions Nd 3+ by the green algae species euglena gracilis was investigated with a comparison between the normal cells and immobilized ones. The new Leipzig Nanoprobe, LIPSION, was used to produce a proton beam with 2 μm size and 0.5 nA beam current for this study. PIXE and RBS techniques were used for analysis and imaging. The observation of small metal rich spores (<10 μm) surrounding both of the fossils and the living cells proved the existence of some specific receptor sites which bind metal carrier ligands at the microbic surface. The bioaccumulation efficiency of neodymium by the algae cells was 10 times higher for immobilized algae cells. It confirms the fact that the algae immobilization is an useful technique to improve its metal bioaccumulation

  11. Quantitative X-ray fluorescence analysis at the ESRF ID18F microprobe

    Vekemans, B.; Vincze, L.; Somogyi, A.; Drakopoulos, M.; Kempenaers, L.; Simionovici, A.; Adams, F.

    2003-01-01

    The new ID18F end-station at the European synchrotron radiation facility (ESRF) in Grenoble (France) is dedicated to sensitive and accurate quantitative micro-X-ray fluorescence (XRF) analysis at the ppm level with accuracy better than 10% for elements with atomic numbers above 18. For accurate quantitative analysis, given a high level of instrumental stability, major steps are the extraction and conversion of experimental X-ray line intensities into elemental concentrations. For this purpose a two-step quantification approach was adopted. In the first step, the collected XRF spectra are deconvoluted on the basis of a non-linear least-squares fitting algorithm (AXIL). The extracted characteristic line intensities are then used as input for a detailed Monte Carlo (MC) simulation code dedicated to XRF spectroscopy taking into account specific experimental conditions (excitation/detection) as well as sample characteristics (absorption and enhancement effects, sample topology, heterogeneity etc.). The iterative use of the MC code gives a 'no-compromise' solution for the quantification problem

  12. Quantitative X-ray fluorescence analysis at the ESRF ID18F microprobe

    Vekemans, B. E-mail: vekemans@uia.ua.ac.be; Vincze, L.; Somogyi, A.; Drakopoulos, M.; Kempenaers, L.; Simionovici, A.; Adams, F

    2003-01-01

    The new ID18F end-station at the European synchrotron radiation facility (ESRF) in Grenoble (France) is dedicated to sensitive and accurate quantitative micro-X-ray fluorescence (XRF) analysis at the ppm level with accuracy better than 10% for elements with atomic numbers above 18. For accurate quantitative analysis, given a high level of instrumental stability, major steps are the extraction and conversion of experimental X-ray line intensities into elemental concentrations. For this purpose a two-step quantification approach was adopted. In the first step, the collected XRF spectra are deconvoluted on the basis of a non-linear least-squares fitting algorithm (AXIL). The extracted characteristic line intensities are then used as input for a detailed Monte Carlo (MC) simulation code dedicated to XRF spectroscopy taking into account specific experimental conditions (excitation/detection) as well as sample characteristics (absorption and enhancement effects, sample topology, heterogeneity etc.). The iterative use of the MC code gives a 'no-compromise' solution for the quantification problem.

  13. Freeze-drying and related preparation techniques for biological microprobe analysis

    Wroblewski, R.; Wroblewski, J.; Anniko, M.; Edstroem, L.P.

    1985-01-01

    An X-ray microanalytical and morphological investigation has been carried out on rapidly frozen, freeze-dried or freeze-substituted tissues. A comparison was made between different embedding and polymerization procedures following freeze-substitution and freeze-drying. The investigation also included an analysis of specimens infiltrated, embedded and polymerized by ultraviolet irradiation at low temperatures with Lowicryl HM20. The morphological preservation of Lowicryl embedded tissue was adequate for the identification of different cell structures like nuclei, mitochondria, lysosomes and different types of endoplasmic reticulum. X-ray microanalytical investigation of low temperature embedded material displayed an elemental composition of cells and organelles similar to that found in freeze-dried cyosections. Compared with freeze-dried cryosections, low temperature embedded material could be sectioned for light microscopy and area of interest chosen for further thin sectioning. This is of great importance in work with tissues with complicated morphology and heterogenous cell populations

  14. High current pulsed positron microprobe

    Howell, R.H.; Stoeffl, W.; Kumar, A.; Sterne, P.A.; Cowan, T.E.; Hartley, J.

    1997-01-01

    We are developing a low energy, microscopically focused, pulsed positron beam for defect analysis by positron lifetime spectroscopy to provide a new defect analysis capability at the 10 10 e + s -l beam at the Lawrence Livermore National Laboratory electron linac. When completed, the pulsed positron microprobe will enable defect specific, 3-dimensional maps of defect concentrations with sub-micron resolution of defect location. By coupling these data with first principles calculations of defect specific positron lifetimes and positron implantation profiles we will both map the identity and concentration of defect distributions

  15. The Melbourne proton microprobe

    Legge, G.J.F.; McKenzie, C.D.; Mazzolini, A.P.

    1979-01-01

    A scanning proton microprobe is described which operates in ultra-high vacuum with a resolution of ten microns. The operating principles and main features of the design are discussed and the ability of such an instrument to detect trace elements down to a few ppm by mass is illustrated

  16. Laser microprobe mass analysis (LAMMA) of aluminum and lead in fine roots and their ectomycorrhizal mantles of Norway spruce (Picea abies (L.) Karst.).

    Eeckhaoudt, S; Vandeputte, D; Van Praag, H; Van Grieken, R; Jacob, W

    1992-03-01

    Fine roots and ectomycorrhizal root tips were sampled in a Norway spruce (Picea abies (L.) Karst.) stand in the eastern part of the Belgian Ardennes. The cellular and partly subcellular localizations of aluminum and lead were identified by the micro-analytical laser microprobe mass analysis (LAMMA) technique. In fine roots with secondary structure, localization of aluminum was limited to the peripheral cell layers. Lead was found in the outer layers, and also in the primary phloem. Aluminum penetrated the mycorrhizal mantle, but lead was seldom detected in ectomycorrhizae.

  17. Optically continuous silcrete quartz cements of the St. Peter Sandstone: High precision oxygen isotope analysis by ion microprobe

    Kelly, Jacque L.; Fu, Bin; Kita, Noriko T.; Valley, John W.

    2007-08-01

    A detailed oxygen isotope study of detrital quartz and authigenic quartz overgrowths from shallowly buried (ratio by laser fluorination, resulting in an average δ 18O of 10.0 ± 0.2‰ (1SD, n = 109). Twelve thin sections were analyzed by CAMECA-1280 ion microprobe (6-10 μm spot size, analytical precision better than ±0.2‰, 1SD). Detrital quartz grains have an average δ 18O of 10.0 ± 1.4‰ (1SD, n = 91) identical to the data obtained by laser fluorination. The ion microprobe data reveal true variability that is otherwise lost by homogenization of powdered samples necessary for laser fluorination. Laser fluorination uses samples that are one million times larger than the ion microprobe. Whole rock (WR) samples from the 53 rocks were analyzed by laser fluorination, giving δ 18O between 9.8‰ and 16.7‰ ( n = 110). Quartz overgrowths in thin sections from 10 rocks were analyzed by ion microprobe and average δ 18O = 29.3 ± 1.0‰ (1SD, n = 161). Given the similarity, on average, of δ 18O for all detrital quartz grains and for all quartz overgrowths, samples with higher δ 18O(WR) values can be shown to have more cement. The quartz cement in the 53 rocks, calculated by mass balance, varies from outlier at 33 vol.% cement. Eolian samples have an average of 11% cement compared to marine samples, which average 4% cement. Two models for quartz cementation have been investigated: high temperature (50-110 °C) formation from ore-forming brines related to Mississippi Valley Type (MVT) mineralization and formation as silcretes at low temperature (10-30 °C). The homogeneity of δ 18O for quartz overgrowths determined by ion microprobe rules out a systematic regional variation of temperature as predicted for MVT brines and there are no other known heating events in these sediments that were never buried to depths >1 km. The data in this study suggest that quartz overgrowths formed as silcretes in the St. Peter Sandstone from meteoric water with δ 18O values of -10

  18. San Francisco Estuary Striped Bass Migration History Determined by Electron-microprobe Analysis of Otolith Sr/Ca Ratio

    Ostrach, D J; Phillis, C C; Weber, P K; Ingram, B L; Zinkl, J G

    2004-09-17

    Habitat use has been shown to be an important factor in the bioaccumulation of contaminants in striped bass. This study examines migration in striped bass as part of a larger study investigating bioaccumulation and maternal transfer of xenobiotics to progeny in the San Francisco Estuary system. Habitat use, residence time and spawning migration over the life of females (n = 23) was studied. Female striped bass were collected between Knights Landing and Colusa on the Sacramento River during the spawning runs of 1999 and 2001. Otoliths were removed, processed and aged via otolith microstructure. Subsequently, otoliths were analyzed for strontium/calcium (Sr/Ca) ratio using an electron-microprobe to measure salinity exposure and to distinguish freshwater, estuary, and marine habitat use. Salinity exposure during the last year before capture was examined more closely for comparison of habitat use by the maternal parent to contaminant burden transferred to progeny. Results were selectively confirmed by ion microprobe analyses for habitat use. The Sr/Ca data demonstrate a wide range of migratory patterns. Age of initial ocean entry differs among individuals before returning to freshwater, presumably to spawn. Some fish reside in freshwater year-round, while others return to more saline habitats and make periodic migrations to freshwater. Frequency of habitat shifts and residence times differs among fish, as well as over the lifetime of individual fish. While at least one fish spent its final year in freshwater, the majority of spawning fish spent their final year in elevated salinity. However, not all fish migrated to freshwater to spawn in the previous year. Results from this investigation concerning migration history in striped bass can be combined with contaminant and histological developmental analyses to better understand the bioaccumulation of contaminants and the subsequent effects they and habitat use have on fish populations in the San Francisco Estuary system.

  19. Application of synchrotron-radiation-based x-ray microprobe techniques for the analysis of recombination activity of metals precipitated at Si/SiGe misfit dislocations

    Vyvenko, O F; Istratov, A A; Weber, E R; Kittler, M; Seifert, W

    2002-01-01

    In this study we report application of synchrotron-radiation-based x-ray microprobe techniques (the x-ray-beam-induced current (XBIC) and x-ray fluorescence (mu-XRF) methods) to the analysis of the recombination activity and space distribution of copper and iron in the vicinity of dislocations in silicon/silicon-germanium structures. A combination of these two techniques enables one to study the chemical nature of the defects and impurities and their recombination activity in situ and to map metal clusters with a micron-scale resolution. XRF analysis revealed that copper formed clearly distinguishable precipitates along the misfit dislocations. A proportional dependence between the XBIC contrast and the number of copper atoms in the precipitates was established. In hydrogen-passivated iron-contaminated samples we observed clusters of iron precipitates which had no recombination activity detectable by the XBIC technique as well as iron clusters which were not completely passivated.

  20. Comparison of photon correlation spectroscopy with photosedimentation analysis for the determination of aqueous colloid size distributions

    Rees, Terry F.

    1990-01-01

    Colloidal materials, dispersed phases with dimensions between 0.001 and 1 μm, are potential transport media for a variety of contaminants in surface and ground water. Characterization of these colloids, and identification of the parameters that control their movement, are necessary before transport simulations can be attempted. Two techniques that can be used to determine the particle-size distribution of colloidal materials suspended in natural waters are compared. Photon correlation Spectroscopy (PCS) utilizes the Doppler frequency shift of photons scattered off particles undergoing Brownian motion to determine the size of colloids suspended in water. Photosedimentation analysis (PSA) measures the time-dependent change in optical density of a suspension of colloidal particles undergoing centrifugation. A description of both techniques, important underlying assumptions, and limitations are given. Results for a series of river water samples show that the colloid-size distribution means are statistically identical as determined by both techniques. This also is true of the mass median diameter (MMD), even though MMD values determined by PSA are consistently smaller than those determined by PCS. Because of this small negative bias, the skew parameters for the distributions are generally smaller for the PCS-determined distributions than for the PSA-determined distributions. Smaller polydispersity indices for the distributions are also determined by PCS.

  1. The upgraded Amsterdam nuclear microprobe

    Vis, R.D.; Kramer, J.L.A.M.; Tros, G.H.J.; Langevelde, F. van; Mars, L.

    1993-01-01

    The improvement of the facilities at our University consists of three phases. In phase 1, a 1.7 MV NEC tandem-Pelletron accelerator has been installed. The accelerator serves as injector for two beam lines, subsequently for macro- and micro-analysis. Moreover, an interconnection has been made with a beam line from our 400 kV high voltage Van de Graaff accelerator in order to enable injection of these very intense low energy beams in these two lines. Apart from new vacuum equipment and conventional beam steering and focussing elements, the experimental facilities are replaced from the cyclotron experimental hall to the newly organised experimental hall. In the phases 2 and 3, which are not yet completed, a second ion source for the Pelletron and a new or extended focussing unit for the microprobe will complete the overall operation. (orig.)

  2. PIXE macro and microprobe techniques in archaeometry

    Brissaud, I.; Lagarde, G.; Houdayer, A.

    1987-01-01

    PIXE analysis method is applied to archaeometry problems. Advantages and disadvantages are emphasized. Some examples are presented which show the difficulties: especially important heterogeneities of ceramics, old coins and metals restrain from the use of this technique. Other analysis systems, less expensive, like electron microbrobe or x-ray fluorescence spectrometry, are compared with conventional PIXE method. The importance of proton microprobe is explained. (author) 40 refs.; 7 figs.; 5 tabs

  3. Study on mineral components of rat calvaria by means of X-ray powder diffraction analysis and Raman microprobe spectroscopy

    Tamura, Norihiro [Meikai Univ., Sakado, Saitama (Japan). School of Dentistry

    2000-07-01

    The present study was designed to examine the occurrence of the precursor minerals of hydroxyapatite (HA) during the process of HA formation in the rat calvaria. Dried and powdered rat calvaria and synthetic samples, such as HA, dicalcium phosphate dihydrate (DCPD), octacalcium phosphate (OCP), ({beta}-calcium pyrophosphate) and ({beta}-tricalcium phosphate), were used. Determinations were carried out by X-ray powder diffraction and Raman microprobe spectrometry. In general, significant widening of the diffraction peaks was shown to occur after the plasma ashing was performed for the X-ray diffraction. As a result, two adjacent peaks seen normally in the diffraction angles (2 {theta}) 30-35 deg, which is a characteristic feature of HA, were found to fuse with each other, forming a widened single peak. Also, there was a tendency for the intensity of the diffraction peaks to increase with age. With regard to the effect of plasma ashing on the crystallograms of synthetic specimens, all specimens manifested sharp peak patterns except DCPD and OCP. In contrast, a widening of diffraction peaks was observed in the DCPD and OCP samples, indicating that crystallinity had changed during the pretreatment. Results obtained from both vital and synthetic samples after heat treatment at 1000 deg C were as follow: Clearcut diffraction patterns, characteristics of HA, were obtained in all of the calvaria samples. Further, {beta}-TCP was produced by heat treatment of OCP, and its pattern was detected in the samples from rats younger than 6 days of age. Amounts of {beta}-TCP in percentage were disclosed to be 40.2% in embryonal samples, 28.4% in newborn samples, and 18.6% in 6-day-old samples. But no {beta}-TCP could be detected in the 12-week-old samples, indicating that the amount of {beta}-TCP in calvaria decreased with age. We also found that ashing pretreatment did not cause any changes in the samples of HA, {beta}-CPP, and {beta}-TCP. Further, DCPD and {beta}-CPP samples shared

  4. Study on mineral components of rat calvaria by means of X-ray powder diffraction analysis and Raman microprobe spectroscopy

    Tamura, Norihiro

    2000-01-01

    The present study was designed to examine the occurrence of the precursor minerals of hydroxyapatite (HA) during the process of HA formation in the rat calvaria. Dried and powdered rat calvaria and synthetic samples, such as HA, dicalcium phosphate dihydrate (DCPD), octacalcium phosphate (OCP), (β-calcium pyrophosphate) and (β-tricalcium phosphate), were used. Determinations were carried out by X-ray powder diffraction and Raman microprobe spectrometry. In general, significant widening of the diffraction peaks was shown to occur after the plasma ashing was performed for the X-ray diffraction. As a result, two adjacent peaks seen normally in the diffraction angles (2 θ) 30-35 deg, which is a characteristic feature of HA, were found to fuse with each other, forming a widened single peak. Also, there was a tendency for the intensity of the diffraction peaks to increase with age. With regard to the effect of plasma ashing on the crystallograms of synthetic specimens, all specimens manifested sharp peak patterns except DCPD and OCP. In contrast, a widening of diffraction peaks was observed in the DCPD and OCP samples, indicating that crystallinity had changed during the pretreatment. Results obtained from both vital and synthetic samples after heat treatment at 1000 deg C were as follow: Clearcut diffraction patterns, characteristics of HA, were obtained in all of the calvaria samples. Further, β-TCP was produced by heat treatment of OCP, and its pattern was detected in the samples from rats younger than 6 days of age. Amounts of β-TCP in percentage were disclosed to be 40.2% in embryonal samples, 28.4% in newborn samples, and 18.6% in 6-day-old samples. But no β-TCP could be detected in the 12-week-old samples, indicating that the amount of β-TCP in calvaria decreased with age. We also found that ashing pretreatment did not cause any changes in the samples of HA, β-CPP, and β-TCP. Further, DCPD and β-CPP samples shared the same diffraction pattern, and OCP

  5. Probing Dynamics in Colloidal Crystals with Pump-Probe Experiments at LCLS: Methodology and Analysis

    Nastasia Mukharamova

    2017-05-01

    Full Text Available We present results of the studies of dynamics in colloidal crystals performed by pump-probe experiments using an X-ray free-electron laser (XFEL. Colloidal crystals were pumped with an infrared laser at a wavelength of 800 nm with varying power and probed by XFEL pulses at an energy of 8 keV with a time delay up to 1000 ps. The positions of the Bragg peaks, and their radial and azimuthal widths were analyzed as a function of the time delay. The spectral analysis of the data did not reveal significant enhancement of frequencies expected in this experiment. This allowed us to conclude that the amplitude of vibrational modes excited in colloidal crystals was less than the systematic error caused by the noise level.

  6. Radioactive colloids

    Bergqvist, L.

    1987-01-01

    Different techniques for the characterization of radioactive colloids, used in nuclear medicine, have been evaluated and compared. Several radioactive colloids have been characterized in vitro and in vivo and tested experimentally. Colloid biokinetics following interstitial or intravenous injection were evaluated with a scintillation camera technique. Lymphoscintigraphy with a Tc-99-labelled antimony sulphur colloid was performed in 32 patients with malignant melanoma in order to evaluate the technique. Based on the biokinetic results, absorbed doses in tissues and organs were calculated. The function of the reticuloendothelial system has been evaluated in rats after inoculation with tumour cells. Microfiltration and photon correlation spectroscopy were found to be suitable in determining activity-size and particle size distributions, respectively. Maximal lymph node uptake following subcutaneous injection was found to correspond to a colloid particle size between 10 and 50 nm. Lymphoscintigraphy was found to be useful in the study of lymphatic drainage from the primary tumour site in patients with malignant melanoma on the trunk. Quantitative analysis of ilio-inguinal lymph node uptake in patients with malignant melanoma on the lower extremities was, however, found to be of no value for the detection of metastatic disease in lymph nodes. High absorbed doses may be received in lymph nodes (up to 1 mGy/MBq) and at the injection site (about 10 mGy/MBq). In an experimental study it was found that the relative colloid uptake in bone marrow and spleen depended on the total number of intravenously injected particles. This may considerably affect the absorbed dose in these organs. (author)

  7. The Stanford-U.S. Geological Survey SHRIMP ion microprobe--a tool for micro-scale chemical and isotopic analysis

    Bacon, Charles R.; Grove, Marty; Vazquez, Jorge A.; Coble, Matthew A.

    2012-01-01

    Answers to many questions in Earth science require chemical analysis of minute volumes of minerals, volcanic glass, or biological materials. Secondary Ion Mass Spectrometry (SIMS) is an extremely sensitive analytical method in which a 5–30 micrometer diameter "primary" beam of charged particles (ions) is focused on a region of a solid specimen to sputter secondary ions from 1–5 nanograms of the sample under high vacuum. The elemental abundances and isotopic ratios of these secondary ions are determined with a mass spectrometer. These results can be used for geochronology to determine the age of a region within a crystal thousands to billions of years old or to precisely measure trace abundances of chemical elements at concentrations as low as parts per billion. A partnership of the U.S. Geological Survey and the Stanford University School of Earth Sciences operates a large SIMS instrument, the Sensitive High-Resolution Ion Microprobe with Reverse Geometry (SHRIMP–RG) on the Stanford campus.

  8. Saturated Zone Colloid Transport

    H. S. Viswanathan

    2004-01-01

    This scientific analysis provides retardation factors for colloids transporting in the saturated zone (SZ) and the unsaturated zone (UZ). These retardation factors represent the reversible chemical and physical filtration of colloids in the SZ. The value of the colloid retardation factor, R col is dependent on several factors, such as colloid size, colloid type, and geochemical conditions (e.g., pH, Eh, and ionic strength). These factors are folded into the distributions of R col that have been developed from field and experimental data collected under varying geochemical conditions with different colloid types and sizes. Attachment rate constants, k att , and detachment rate constants, k det , of colloids to the fracture surface have been measured for the fractured volcanics, and separate R col uncertainty distributions have been developed for attachment and detachment to clastic material and mineral grains in the alluvium. Radionuclides such as plutonium and americium sorb mostly (90 to 99 percent) irreversibly to colloids (BSC 2004 [DIRS 170025], Section 6.3.3.2). The colloid retardation factors developed in this analysis are needed to simulate the transport of radionuclides that are irreversibly sorbed onto colloids; this transport is discussed in the model report ''Site-Scale Saturated Zone Transport'' (BSC 2004 [DIRS 170036]). Although it is not exclusive to any particular radionuclide release scenario, this scientific analysis especially addresses those scenarios pertaining to evidence from waste-degradation experiments, which indicate that plutonium and americium may be irreversibly attached to colloids for the time scales of interest. A section of this report will also discuss the validity of using microspheres as analogs to colloids in some of the lab and field experiments used to obtain the colloid retardation factors. In addition, a small fraction of colloids travels with the groundwater without any significant retardation. Radionuclides irreversibly

  9. Looking into individual coffee beans during the roasting process: direct micro-probe sampling on-line photo-ionisation mass spectrometric analysis of coffee roasting gases.

    Hertz-Schünemann, Romy; Streibel, Thorsten; Ehlert, Sven; Zimmermann, Ralf

    2013-09-01

    A micro-probe (μ-probe) gas sampling device for on-line analysis of gases evolving in confined, small objects by single-photon ionisation time-of-flight mass spectrometry (SPI-TOFMS) was developed. The technique is applied for the first time in a feasibility study to record the formation of volatile and flavour compounds during the roasting process within (inside) or in the direct vicinity (outside) of individual coffee beans. A real-time on-line analysis of evolving volatile and semi-volatile organic compounds (VOC and SVOC) as they are formed under the mild pyrolytic conditions of the roasting process was performed. The soft-ionisation mass spectra depict a molecular ion signature, which is well corresponding with the existing knowledge of coffee roasting and evolving compounds. Additionally, thereby it is possible to discriminate between Coffea arabica (Arabica) and Coffea canephora (Robusta). The recognized differences in the roasting gas profiles reflect the differences in the precursor composition of the coffee cultivars very well. Furthermore, a well-known set of marker compounds for Arabica and Robusta, namely the lipids kahweol and cafestol (detected in their dehydrated form at m/z 296 and m/z 298, respectively) were observed. If the variation in time of different compounds is observed, distinctly different evolution behaviours were detected. Here, phenol (m/z 94) and caffeine (m/z 194) are exemplary chosen, whereas phenol shows very sharp emission peaks, caffeine do not have this highly transient behaviour. Finally, the changes of the chemical signature as a function of the roasting time, the influence of sampling position (inside, outside) and cultivar (Arabica, Robusta) is investigated by multivariate statistics (PCA). In summary, this pilot study demonstrates the high potential of the measurement technique to enhance the fundamental knowledge of the formation processes of volatile and semi-volatile flavour compounds inside the individual coffee bean.

  10. Analysis of corrosions-products in tissue samples near surgical implants by means of LAMMA (Laser Microprobe Mass Analyzer) and ICP-MS (Inductively Coupled Plasma Mass Spectrometer)

    Schlagenhaufen, C.

    1996-08-01

    In this work corrosion products of surgical implants in tissue samples were identified. For the characterization of the corrosion products the LAMMA 500 (Laser Microprobe Mass Analyzer) was used. Additional analysis were made with the ICP-MS (Inductively Coupled Plasma Mass Spectrometer) to determine the concentration of chromium, cobalt, nickel, and molybdenum in the tissues. In the first part several synthetic chromium- and molybdenum compounds were investigated with LAMMA. With the anionic mass spectra of the chromium-compounds it is possible to the oxidation state of chromium. The mass spectra of the synthetic compounds were used to identify, the compounds in the corrosion products. In the second part thin sections prepared from the tissue samples from the surrounding of the implants were analyzed. Several embedding and cutting methods were tested. Histological staining methods and LAMMA spectra were used to characterize the deposits in the tissue. Three different deposits were found in the tissue. In all tissues metal splinters from the implant were found. In most of the tissues iron-rich deposits were found, that were identified as iron-phosphate. As definitive corrosion products of the implant mixtures of chromium(III)phosphate, calcium molybdate, calcium phosphate and chromium(III) molybdate were identified. The ICP-MS results show in comparison to normal values, very high concentrations for chromium, nickel, cobalt and molybdenum. These results support the conclusions based on LAMMA results. The results of these investigations clearly indicate, that stainless steel implants, are not corrosion-resistant in the body. Relatively high amounts of the constituents, of the implant dissolved, and are deposited as solid compounds in the tissue next to the implant. (author)

  11. Colloidal organization

    Okubo, Tsuneo

    2015-01-01

    Colloidal Organization presents a chemical and physical study on colloidal organization phenomena including equilibrium systems such as colloidal crystallization, drying patterns as an example of a dissipative system and similar sized aggregation. This book outlines the fundamental science behind colloid and surface chemistry and the findings from the author's own laboratory. The text goes on to discuss in-depth colloidal crystallization, gel crystallization, drying dissipative structures of solutions, suspensions and gels, and similar-sized aggregates from nanosized particles. Special emphas

  12. Dynamic analysis of the photoenhancement process of colloidal quantum dots with different surface modifications

    Valledor Llopis, Marta; Campo Rodriguez, Juan Carlos; Ferrero Martin, Francisco J [Departamento de Ingenieria Electrica, Electronica, C y S Universidad de Oviedo, Campus de Gijon s/n, 33204 Gijon, Asturias, (Spain); Coto, Ana Maria; Fernandez-Argueelles, Maria T; Costa-Fernandez, J M; Sanz-Medel, A [Departamento de Quimica Fisica y Analitica, Universidad de Oviedo, Campus del Cristo, 33006 Oviedo, Asturias (Spain)

    2011-09-23

    Photoinduced fluorescence enhancement of colloidal quantum dots (QDs) is a hot topic addressed in many studies due to its great influence on the bioanalytical performance of such nanoparticles. However, understanding of this process is not a simple task, and it cannot be explained by a general mechanism as it greatly depends on the QDs' nature, solubilization strategies, surrounding environment, etc. In this vein, we have critically compared the behavior of CdSe QDs (widely used in bioanalytical applications) with different surface modifications (ligand exchange and polymer coating), in different controlled experimental conditions, in the presence-absence of the ZnS layer and in different media when exposed for long times to intense UV irradiation. Thus six different types of colloidal QDs were finally studied. This research was carried out from a novel perspective, based on the analysis of the dynamic behavior of the photoactivation process (of great interest for further applications of QDs as labels in biomedical applications). The results showed a different behavior of the studied colloidal QDs after UV irradiation in terms of their photoluminescence characteristics, potential toxicity due to metal release to the environment, nanoparticle stability and surface coating degradation.

  13. Dynamic analysis of the photoenhancement process of colloidal quantum dots with different surface modifications

    Valledor Llopis, Marta; Campo Rodriguez, Juan Carlos; Ferrero Martin, Francisco J; Coto, Ana Maria; Fernandez-Argueelles, Maria T; Costa-Fernandez, J M; Sanz-Medel, A

    2011-01-01

    Photoinduced fluorescence enhancement of colloidal quantum dots (QDs) is a hot topic addressed in many studies due to its great influence on the bioanalytical performance of such nanoparticles. However, understanding of this process is not a simple task, and it cannot be explained by a general mechanism as it greatly depends on the QDs' nature, solubilization strategies, surrounding environment, etc. In this vein, we have critically compared the behavior of CdSe QDs (widely used in bioanalytical applications) with different surface modifications (ligand exchange and polymer coating), in different controlled experimental conditions, in the presence-absence of the ZnS layer and in different media when exposed for long times to intense UV irradiation. Thus six different types of colloidal QDs were finally studied. This research was carried out from a novel perspective, based on the analysis of the dynamic behavior of the photoactivation process (of great interest for further applications of QDs as labels in biomedical applications). The results showed a different behavior of the studied colloidal QDs after UV irradiation in terms of their photoluminescence characteristics, potential toxicity due to metal release to the environment, nanoparticle stability and surface coating degradation.

  14. UZ Colloid Transport Model

    McGraw, M.

    2000-01-01

    The UZ Colloid Transport model development plan states that the objective of this Analysis/Model Report (AMR) is to document the development of a model for simulating unsaturated colloid transport. This objective includes the following: (1) use of a process level model to evaluate the potential mechanisms for colloid transport at Yucca Mountain; (2) Provide ranges of parameters for significant colloid transport processes to Performance Assessment (PA) for the unsaturated zone (UZ); (3) Provide a basis for development of an abstracted model for use in PA calculations

  15. Synchrotron radiation XRF microprobe study of human bone tumor slice

    Huang Yuying; Zhao Limin; Wang Zhouguang; Shao Hanru; Li Guangcheng; Wu Yingrong; He Wei; Lu Jianxin; He Rongguo

    1999-01-01

    The experimental apparatus of X-ray fluorescence (XRF) microprobe analysis at Beijing Synchrotron Radiation Facility (BSRF) is described. Using the bovine liver as the standard reference, the minimum detection limit (MDL) of trace element was measured to determine the capability of biological sample analysis by synchrotron radiation XRF microprobe. The relative change of the content of the major or trace element in the normal and tumor part of human bone tissue slice was investigated. The experimental result relation to the clinical medicine was also discussed. (author)

  16. Arсhaeomineralogy of Ancient Nonferrous Metallurgy Pieces of the Perm Region: Experience of Usage of Electron Microprobe Analysis

    I. I. Chaykovsky

    2016-12-01

    Full Text Available A series of archaeological features has been studied by means of the scanning electronic microscopy. It was shown that due to the oxidation process, the surface layer is enriched with some elements, which were present at unaltered metal (Ag, Pb and those included later (As, Zn, Pb. It imposes meaningful limitation for use of the X-ray fluorescence and spectral analysis, which allow obtaining only total (patina + metal composition. Sixteen minerals (oxides, carbonates, sulphates, chlorides, phosphates, sulfides and native phases are established in patina composition. Tin bronze structure contains the impurities, which may be an evidence of import to Perm Region of tin and silver possibly from Altai, tin and lead possibly from Karelia during "harinsky" and "rodanovsky" cultures respectively. Various composition of the alloys used for casting and filigree witnesses that ancient metallurgists had known about alloys handling. The presence of barium and fluorine can tell us about composition of the used furnacecharge. The obtained data may be the basis for chemical-metallurgical typification of pieces from nonferrous (and noble metals.

  17. X-ray microprobe analysis of the retina and RPE in sheep with ovine ceroid-lipofuscinosis

    Samuelson, D.A.; Armstrong, D.; Jolly, R.

    1990-01-01

    Ovine ceroid-lipofuscinosis (OCL) is one animal model for the human condition, and because autofluorescent lipopigments are prominent in the brain and eye, it may also prove useful as a model for aging. For example, a progressive decline in electrical recording from brain and retina are observed in both aging and OCL. Samples of retinal and retinal pigment epithelial (RPE) tissues were obtained from a young control. 2 animals with OCL and a normal aged sheep. Specimens were cryo-fractured and examined by scanning electron microscopy/x-ray microanalysis. Measurements made of 6 individual cells in the ganglion layer of OCL specimens, the remainder of the retina, and RPE showed age-related changes in zinc, iron, and copper which were associated with lipopigment accumulation in the RPE. There was marked decrease in phosphate, sulfur, and manganese levels, as photoreceptor cells and their outer segments are lost in the disease process. This is the first report of metal analysis in the retina and RPE in a disease entity, and as a function of normal aging

  18. Microprobe analysis, iono- and photo-luminescence of Mn2+ activated ZnGa2O4 fibres

    Santos, N.F.; Fernandes, A.J.S.; Alves, L.C.; Sobolev, N.A.; Alves, E.; Lorenz, K.; Costa, F.M.; Monteiro, T.

    2013-01-01

    Cubic ZnGa 2 O 4 fibres have been grown by the laser floating zone technique with different pulling rates. In fibres activated with manganese ions, the room temperature photo- and iono-luminescence is dominated by an intense green emission which is observed by the naked eye. The green band is due to an overlap of the 4 T 1 → 6 A 1 intraionic transitions of the Mn 2+ ions in different sites in the gallate host. The fibres’ photoluminescence spectra have been found to be dependent on the excitation energy. Additionally, the intensity of the green photo- and iono-luminescence is strongly sensitive to the measurement temperature and proton irradiation time. Micro PIXE analysis was used in order to verify the homogeneous distribution of the Mn luminescence activators and determine its concentration as well as for verification of impurity contents that may have been incorporated during the fibres growth. The potential of ionoluminescence measurements for characterization of optical materials is discussed

  19. Convective Diffusion from Strip-like Microprobes into Colloidal Suspensions

    Wein, Ondřej

    2010-01-01

    Roč. 53, 9-10 (2010), s. 1856-1867 ISSN 0017-9310 R&D Projects: GA ČR GA104/08/0428; GA ČR GA104/09/0972 Institutional research plan: CEZ:AV0Z40720504 Keywords : electrodiffusion friction probes * microdisperse fluid flow * longitudinal diffusion Subject RIV: CI - Industrial Chemistry, Chemical Engineering Impact factor: 1.898, year: 2010

  20. Quantitative microanalysis with a nuclear microprobe

    Themner, Klas.

    1989-01-01

    The analytical techniques of paticle induced X-ray emission (PIXE) and Rutherford backscattering (RBS), together with the nuclear microprobe, form a very powerful tool for performing quantitative microanalysis of biological material. Calibration of the X-ray detection system in the microprobe set-up has been performed and the accuracy of the quantitative procedure using RBS for determination of the areal mass density was investigated. The accuracy of the analysis can be affected by alteration in the elemental concentrations during irradiation due to the radiation damage induced by the very intense beams of ionixing radiation. Loss of matrix elements from freeze-dried tissue sections and polymer films have been studied during proton and photon irradiation and the effect on the accuracy discussed. Scanning the beam over an area of the target, with e.g. 32x32 pixels, in order to produce en elemental map, yields a lot of information and, to be able to make an accurate quantitatification, a fast algorithm using descriptions of the different spectral contributions is of need. The production of continuum X-rays by 2.55 MeV protons has been studied and absolute cross-sections for the bremsstrahlung production from thin carbon and some polymer films determined. For the determination of the bremsstrahlung background knowledge of the amounts of the matrix elements is important and a fast program for the evaluation of spectra of proton back- and forward scattering from biological samples has been developed. Quantitative microanalysis with the nuclear microprobe has been performed on brain tissue from rats subjected to different pathological conditions. Increase in calcium levels and decrease in potssium levels for animals subjected to crebral ischaemia and for animals suffering from epileptic seizures were observed coincidentally with or, in some cases before, visible signs of cell necrosis. (author)

  1. The CEA nuclear microprobe. Description, possibilities, application examples

    Engelmann, C.; Bardy, J.

    1986-05-01

    The nuclear microprobe installed on one of the beam lines of a 4 MV Van de Graaff located in the Research Center of Bruyeres-le-Chatel is described. The various possibilities, particularly the imaging system, and the performances of the instrument are exposed. Two typical application examples concerning, the first, the determination of the deuterium and tritium in glass microballons, the second, the detection and the localization of carbon and oxygen in the superficial layer of lithium hydride pellets, are given. Preliminary results of some other application examples are also presented. The advantages of the nuclear microprobe over the other ponctual analysis techniques are emphasized. 7 refs, 19 figs [fr

  2. Ion microprobe Sr isotope analysis of carbonates with about 5 {mu}m spatial resolution: An example from an ayu otolith

    Sano, Yuji [Center for Advanced Marine Research, Ocean Research Institute, University of Tokyo, Nakano-ku, Tokyo 164-8639 (Japan)], E-mail: ysano@ori.u-tokyo.ac.jp; Shirai, Kotaro [International Coastal Research Center, Ocean Research Institute, University of Tokyo, Otsuchi, Iwate 028-1102 (Japan); Takahata, Naoto; Amakawa, Hiroshi [Center for Advanced Marine Research, Ocean Research Institute, University of Tokyo, Nakano-ku, Tokyo 164-8639 (Japan); Otake, Tsuguo [International Coastal Research Center, Ocean Research Institute, University of Tokyo, Otsuchi, Iwate 028-1102 (Japan)

    2008-08-15

    A high lateral resolution secondary ion mass spectrometer (NanoSIMS NS50 ion microprobe) has been used to measure {sup 87}Sr/{sup 86}Sr ratios in natural CaCO{sub 3} samples. A {approx}2 nA O{sup -} primary beam was used to sputter a 5-7-{mu}m diameter crater on the sample surface and secondary positive ions were extracted for mass analysis using an accelerating voltage of 8 kV and a Mattauch-Herzog geometry. The multi-collector system was adjusted to detect {sup 43}Ca{sup +} (by a detector EM2), {sup 80}Ca{sub 2}{sup +} (EM3), {sup 86}Sr{sup +} (EM4), and {sup 87}Sr{sup +} (EM4b) ions at the same time. Then the magnetic field was scanned for the EM4 to detect {sup 85}Rb{sup +}, {sup 86}Sr{sup +} and {sup 87}Sr{sup +}, while the EM4b can measure {sup 86}Sr{sup +}, {sup 87}Sr{sup +} and {sup 88}Sr{sup +}, respectively. A mass resolution of 3600 at 10% peak height was attained with a flat peak top, while the sensitivity of Sr was about 10 cps/nA/ppm. An aragonite sample (coral skeleton standard; JCp-1) was used as a reference for Sr isotope ratio calibration. Repeated analyses of the JCp-1 show that the {sup 87}Sr/{sup 86}Sr ratio agrees well with the seawater signature within a precision of 0.3 per mille at 2{sigma}, after the series of corrections such as the Ca dimer, {sup 87}Rb, and a mass bias estimated by the {sup 88}Sr/{sup 86}Sr ratio. The method was applied to an otolith (ear-stone) from ayu (Plecoglossus altivelis altivelis) collected from the Yodo river, Japan. Although experimental errors are relatively large, up to 3 per mille at 2{sigma}, the ratios of the core region are higher than the seawater signature while more distal values agree well with seawater. The very outermost part again shows the relatively higher {sup 87}Sr/{sup 86}Sr ratios. The spatial variation of {sup 87}Sr/{sup 86}Sr ratios was consistent with amphidromous migration of the fish, namely, born in the lake and grown in the coastal sea and finally collected in a river.

  3. Ion microprobe Sr isotope analysis of carbonates with about 5 μm spatial resolution: An example from an ayu otolith

    Sano, Yuji; Shirai, Kotaro; Takahata, Naoto; Amakawa, Hiroshi; Otake, Tsuguo

    2008-01-01

    A high lateral resolution secondary ion mass spectrometer (NanoSIMS NS50 ion microprobe) has been used to measure 87 Sr/ 86 Sr ratios in natural CaCO 3 samples. A ∼2 nA O - primary beam was used to sputter a 5-7-μm diameter crater on the sample surface and secondary positive ions were extracted for mass analysis using an accelerating voltage of 8 kV and a Mattauch-Herzog geometry. The multi-collector system was adjusted to detect 43 Ca + (by a detector EM2), 80 Ca 2 + (EM3), 86 Sr + (EM4), and 87 Sr + (EM4b) ions at the same time. Then the magnetic field was scanned for the EM4 to detect 85 Rb + , 86 Sr + and 87 Sr + , while the EM4b can measure 86 Sr + , 87 Sr + and 88 Sr + , respectively. A mass resolution of 3600 at 10% peak height was attained with a flat peak top, while the sensitivity of Sr was about 10 cps/nA/ppm. An aragonite sample (coral skeleton standard; JCp-1) was used as a reference for Sr isotope ratio calibration. Repeated analyses of the JCp-1 show that the 87 Sr/ 86 Sr ratio agrees well with the seawater signature within a precision of 0.3 per mille at 2σ, after the series of corrections such as the Ca dimer, 87 Rb, and a mass bias estimated by the 88 Sr/ 86 Sr ratio. The method was applied to an otolith (ear-stone) from ayu (Plecoglossus altivelis altivelis) collected from the Yodo river, Japan. Although experimental errors are relatively large, up to 3 per mille at 2σ, the ratios of the core region are higher than the seawater signature while more distal values agree well with seawater. The very outermost part again shows the relatively higher 87 Sr/ 86 Sr ratios. The spatial variation of 87 Sr/ 86 Sr ratios was consistent with amphidromous migration of the fish, namely, born in the lake and grown in the coastal sea and finally collected in a river

  4. High resolution, high sensitivity imaging and analysis of minerals and inclusions (fluid and melt) using the new CSIRO-GEMOC nuclear microprobe

    Ryan, C.G.; McInnes, B.M.; Van Achterbergh, E.; Williams, P.J.; Dong, G.; Zaw, K.

    1999-01-01

    Full text: The new CSIRO-GEMOC Nuclear Microprobe (NMP) The instrument was designed specifically for minerals analysis and imaging and to achieve ppm to sub-ppm sensitivity at a spatial resolution of 1-2 μm using X-rays and y-rays induced by MeV energy ion beams. The key feature of the design is a unique magnetic quadrupole quintuplet ion focussing system that combines high current with high spatial resolution (Ryan et al., 1999). These design goals have been achieved or exceeded. On the first day of operation, a spot-size of 1.3 μm was obtained at a beam current of 0.5 nA, suitable for fluid inclusion analysis and imaging. The spot-size grows to just 1.8 μm at 10 nA (3 MeV protons), ideal for mineralogical samples with detection limits down to 0.2 ppm achieved in quantitative, high resolution, trace element images. Applications of the NMP include: research into ore deposit processes through trace element geochemistry, mineralogy and fluid inclusion analysis of ancient deposits and active sea-floor environments, ore characterization, and fundamental studies of mantle processes and extraterrestrial material. Quantitative True Elemental Imaging Dynamic Analysis is a method for projecting quantitative major and trace element images from proton-induced X-ray emission (PIXE) data obtained using the NMP (Ryan et al., 1995). The method un-mixes full elemental spectral signatures to produce quantitative images that can be directly interrogated for the concentrations of all elements in selected areas or line projections, etc. Fluid Inclusion Analysis and Imaging The analysis of fluids trapped as fluid inclusions in minerals holds the key to understanding ore metal pathways and ore formation processes. PIXE analysis using the NMP provides a direct non-destructive method to determine the composition of these trapped fluids with detection limits down to 20 ppm. However, some PIXE results have been controversial, such as the strong partitioning of Cu into the vapour phase (e

  5. Implications of the effective one-component analysis of pair correlations in colloidal fluids with polydispersity

    Pond, Mark J.; Errington, Jeffrey R.; Truskett, Thomas M.

    2011-09-01

    Partial pair-correlation functions of colloidal suspensions with continuous polydispersity can be challenging to characterize from optical microscopy or computer simulation data due to inadequate sampling. As a result, it is common to adopt an effective one-component description of the structure that ignores the differences between particle types. Unfortunately, whether this kind of simplified description preserves or averages out information important for understanding the behavior of the fluid depends on the degree of polydispersity and can be difficult to assess, especially when the corresponding multicomponent description of the pair correlations is unavailable for comparison. Here, we present a computer simulation study that examines the implications of adopting an effective one-component structural description of a polydisperse fluid. The square-well model that we investigate mimics key aspects of the experimental behavior of suspended colloids with short-range, polymer-mediated attractions. To characterize the partial pair-correlation functions and thermodynamic excess entropy of this system, we introduce a Monte Carlo sampling strategy appropriate for fluids with a large number of pseudo-components. The data from our simulations at high particle concentrations, as well as exact theoretical results for dilute systems, show how qualitatively different trends between structural order and particle attractions emerge from the multicomponent and effective one-component treatments, even with systems characterized by moderate polydispersity. We examine consequences of these differences for excess-entropy based scalings of shear viscosity, and we discuss how use of the multicomponent treatment reveals similarities between the corresponding dynamic scaling behaviors of attractive colloids and liquid water that the effective one-component analysis does not capture.

  6. Use of the ion microprobe in geological dating

    Compston, W.; Williams, I.S.; Black, L.P.

    1983-01-01

    SHRIMP, the Sensitive High Resolution Ion Microprobe with computerised control and data acquisition system, has recently been commissioned. It is used within the Research School of Earth Sciences, Australian National University, for the isotopic analysis of geological samples. Principles of operation and geological applications are outlined. One example described is the application to Pb-U dating of zircon

  7. Saturated Zone Colloid Transport

    H. S. Viswanathan

    2004-10-07

    This scientific analysis provides retardation factors for colloids transporting in the saturated zone (SZ) and the unsaturated zone (UZ). These retardation factors represent the reversible chemical and physical filtration of colloids in the SZ. The value of the colloid retardation factor, R{sub col} is dependent on several factors, such as colloid size, colloid type, and geochemical conditions (e.g., pH, Eh, and ionic strength). These factors are folded into the distributions of R{sub col} that have been developed from field and experimental data collected under varying geochemical conditions with different colloid types and sizes. Attachment rate constants, k{sub att}, and detachment rate constants, k{sub det}, of colloids to the fracture surface have been measured for the fractured volcanics, and separate R{sub col} uncertainty distributions have been developed for attachment and detachment to clastic material and mineral grains in the alluvium. Radionuclides such as plutonium and americium sorb mostly (90 to 99 percent) irreversibly to colloids (BSC 2004 [DIRS 170025], Section 6.3.3.2). The colloid retardation factors developed in this analysis are needed to simulate the transport of radionuclides that are irreversibly sorbed onto colloids; this transport is discussed in the model report ''Site-Scale Saturated Zone Transport'' (BSC 2004 [DIRS 170036]). Although it is not exclusive to any particular radionuclide release scenario, this scientific analysis especially addresses those scenarios pertaining to evidence from waste-degradation experiments, which indicate that plutonium and americium may be irreversibly attached to colloids for the time scales of interest. A section of this report will also discuss the validity of using microspheres as analogs to colloids in some of the lab and field experiments used to obtain the colloid retardation factors. In addition, a small fraction of colloids travels with the groundwater without any significant

  8. Experimental analysis of colloid capture by a cylindrical collector in laminar overland flow.

    Wu, Lei; Gao, Bin; Muñoz-Carpena, Rafael

    2011-09-15

    Although colloid-facilitated contaminant transport in water flow is a well-known contamination process, little research has been conducted to investigate the transport of colloidal particles through emergent vegetation in overland flow. In this work, a series of laboratory experiments were conducted to measure the single-collector contact efficiency (η(0)) of colloid capture by a simulated plant stem in laminar lateral flow. Fluorescent microspheres of various sizes were used as experimental colloids. The colloid suspensions were applied to a glass cylinder installed in a small size flow chamber at different flow rates. Two cylinder sizes were tested in the experiment and silicone grease was applied to the cylinder surface to make it favorable for colloid deposition. Our results showed that increases in flow rate and collector size reduced the value of η(0) and a minimum value of η(0) might exist for a colloid size. The experimental data were compared to theoretical predictions of different single-collector contact efficiency models. The results indicated that existing single-collector contact efficiency models underestimated the η(0) of colloid capture by the cylinders in laminar overland flow. A regression equation of η(0) as a function of collector Reynolds number (Re(c)) and Peclet number (N(Pe)) was developed and fit the experimental data very well (R(2) > 0.98). This regression equation can be used to help construct and refine mathematical models of colloid transport and filtration in laminar overland flow on vegetated surfaces.

  9. New electron microprobe for radioactive materials

    Perrot, M.; Geoffroy, G.; Trotabas, M.

    1989-01-01

    The latest model of CAMECA microprobe SX 50R has just been set up in the high activity laboratory of the Centre d'Etudes Nucleaires de SACLAY. It has been especially designed for the examination of nuclear fuel and irradiated materials. The spectrometers are protected from the radioactivity by an armour plate and the entire equipment has been installed into a special cell in order to protect the operators. The special sample holder allows to examine specimens as large as 80 mm in diameter. One of the interesting uses concerns the quantitative determination of the oxygen content in zircaloy oxidized by steam at high temperature. This analysis was made possible by using the new type of crystals (multilayer)

  10. Active colloids

    Aranson, Igor S

    2013-01-01

    A colloidal suspension is a heterogeneous fluid containing solid microscopic particles. Colloids play an important role in our everyday life, from food and pharmaceutical industries to medicine and nanotechnology. It is useful to distinguish two major classes of colloidal suspensions: equilibrium and active, i.e., maintained out of thermodynamic equilibrium by external electric or magnetic fields, light, chemical reactions, or hydrodynamic shear flow. While the properties of equilibrium colloidal suspensions are fairly well understood, active colloids pose a formidable challenge, and the research is in its early exploratory stage. One of the most remarkable properties of active colloids is the possibility of dynamic self-assembly, a natural tendency of simple building blocks to organize into complex functional architectures. Examples range from tunable, self-healing colloidal crystals and membranes to self-assembled microswimmers and robots. Active colloidal suspensions may exhibit material properties not present in their equilibrium counterparts, e.g., reduced viscosity and enhanced self-diffusivity, etc. This study surveys the most recent developments in the physics of active colloids, both in synthetic and living systems, with the aim of elucidation of the fundamental physical mechanisms governing self-assembly and collective behavior. (physics of our days)

  11. Colloidal glasses

    First page Back Continue Last page Overview Graphics. Colloidal glasses. Glassy state is attained when system fails to reach equilibrium due to crowding of constituent particles. In molecular glasses, glassy state is reached by rapidly lowering the temperature. In colloidal glasses, glassy state is reached by increasing the ...

  12. Grimsel colloid exercise

    Degueldre, C.; Longworth, G.; Vilks, P.

    1989-11-01

    The Grimsel Colloid Exercise was an intercomparison exercise which consisted of an in situ sampling phase followed by a colloid characterisation step. The goal of this benchmark exercise, which involved 12 laboratories, was to evaluate both sampling and characterisation techniques with emphasis on the colloid specific size distribution. The sampling phase took place at the Grimsel Test Site between February 1 and 13, 1988 and the participating groups produced colloid samples using the following methods: 1. Cross-flow ultrafiltration with production of membranes loaded with colloids. 2. Tangential diaultrafiltration and production of colloid concentrates. 3. Filtrates produced by each group. 4. Unfiltered water was also collected by PSI in glass bottles, under controlled anaerobic conditions, and by the other sampling groups in various plastic bottles. In addition, on-line monitoring of pH, χ, [O-2] and T of the water and of [O-2] in the atmosphere of the sampling units was carried out routinely. All samples were shipped according to the CoCo Club scheme for characterisation, with emphasis on the size distribution. The exercise differentiates the colloid samples produced on site from those obtained after transfer of the fluid samples to the laboratories. The colloid concentration and size distribution can be determined by scanning electron microscopy (SEM), gravimetry (GRAV), chemical analysis of fluid samples after micro/ultrafiltration (MF/UF) and by transmission single particle counting (PC). The colloid concentration can also be evaluated by transmission electron microscopy (TEM), static and dynamic light scattering (SLS,DLS) and by laser-induced photoacoustic spectroscopy (LPAS). The results are discussed on the basis of the detection limit, lateral resolution and counting conditions of the technique (precision) as well as sample preparation, artefact production and measurement optimisation (accuracy). A good agreement between size distribution results was

  13. Development of a nuclear microprobe and its application to neurobiology

    Tapper, Staffan.

    1989-01-01

    A nuclear microprobe has been developed at the Pelletron accelerator in Lund. The design of the achromatic beam focusing system as well as of the beam scanning system is described. The focusing system consists of three magnetic- and three electrostatic quadrupole lenses together forming an chromatic quadrupole triplet with symmetric focusing properties. The beam quality from the accelerator has been improved by use of ultrathin stripper foils. The nuclear microprobe set-up has been applied to investigation of brain tissue specimens. The elemantal disorder following epileptic seizures has been studied by micro-PIXE analysis. A combination of macro- and micro-PIXE analysis have been utilized in an investigaiton of elemental differences between normal human brain and human brain tumours. In the context of the quantification procedure in micro-PIXE analysis, callibration and X-ray detector response function are discussed. (author)

  14. Applications of the ion microprobe to geochemistry and cosmochemistry

    Shimizu, N.; Hart, S.R.

    1982-01-01

    When a solid surface is subjected to a bombardment of energetic ions, material is ejected from the surface in a process known as sputtering. A part of the sputtered material is ionized and these secondary ions can be analyzed with a mass spectrometer according to a technique known as secondary ion mass spectrometry (SIMS). A description is presented of the present status of geochemical and cosmochemical applications of the ion microprobe. Attention is given to the sputtering event, molecular ion interferences, aspects of isotopic fractionation, secondary ion intensities in polycomponent materials, and questions of trace element analysis. Geochemical applications of the ion microprobe are based on certain advantages over other analytical techniques. These advantages are related to high sensitivity, low background, and the capability of in situ analysis of isotopic composition. The distribution of trace elements in minerals is considered, along with isotope anomalies, isotope zoning, diffusion studies, and depth profiling

  15. New generation nuclear microprobe systems

    Jamieson, David N.

    2001-01-01

    Over the past 20 years, the minimum probe size for nuclear microscopy has stayed around 1 μm with only a few groups reporting a sub-micron probe size around 0.5 μm. No breakthroughs in nuclear microprobe design have been forthcoming to produce dramatic improvements in spatial resolution. The difficulties of breaking the constraints that are preventing reduction of the probe size have been well recognised in the past. Over the past 5 years it has become clear that some of these constraints may not be as limiting as first thought. For example, chromatic aberration clearly is not as significant as implied from first-order ion optics calculations. This paper reviews the constraints in view of the increased understanding of the past 5 years and looks at several new approaches, presently being evaluated in Melbourne and elsewhere, on how to make progress. These approaches include modified RF ion sources for improved beam brightness and exploitation of relaxed constraints on some lens aberrations allowing the use of high demagnification probe forming lens systems

  16. 7th international conference on Nuclear microprobe technology and applications

    2000-01-01

    This colloquium gives an up-to-date report on the continuously advancing applications and development of microbeam technology. It presents abstracts and oral contributions in the following domains: microprobes facilities, analysis techniques, imaging techniques, micro-ion beam modification of materials, microelectronics, applications in Material Sciences in Biology in Medicine in earth and planetary Sciences in environment in art in archaeology, alternative techniques. (A.L.B.)

  17. A study of VMS ore deposits by the proton microprobe

    Huston, D.L.; Large, R.R.; Bottril, R.S.; Sie, S.H.; Ryan, C.G.

    1991-01-01

    As part of studies into the mineralogical distribution of gold in volcanogenic massive sulfide (VMS) ore deposits PIXE analysis by the proton microprobe has been used to determine the gold content of pyrite and arsenopyrite from the Rosebery, Mt. Chalmers and Mt. Lyell deposits. In addition, the concentrations of Co, Ni, Cu, Zn, As, Sr, Y, Zr, Mo, Ag, Sb, Te, Au, Tl, Pb and Bi were also determined. 4 refs., 1 tab

  18. Digital pulse processor for ion beam microprobe imaging

    Bogovac, M.; Jaksic, M.; Wegrzynek, D.; Markowicz, A.

    2009-01-01

    Capabilities of spectroscopic ion beam analysis (IBA) techniques that are available in ion microprobe facilities can be greatly improved by the use of digital pulse processing. We report here development of a digital multi parameter data acquisition system suitable for IBA imaging applications. Input signals from charge sensitive preamplifier are conditioned by using a simple circuit and digitized with fast ADCs. The digitally converted signals are processed in real time using FPGA. Implementation of several components of the system is presented.

  19. Colloidal electrophoresis: scaling analysis, Green-Kubo relation, and numerical results

    Duenweg, B; Lobaskin, V; Seethalakshmy-Hariharan, K; Holm, C

    2008-01-01

    We consider electrophoresis of a single charged colloidal particle in a finite box with periodic boundary conditions, where added counterions and salt ions ensure charge neutrality. A systematic rescaling of the electrokinetic equations allows us to identify a minimum set of suitable dimensionless parameters, which, within this theoretical framework, determine the reduced electrophoretic mobility. It turns out that the salt-free case can, on the mean field level, be described in terms of just three parameters. A fourth parameter, which had previously been identified on the basis of straightforward dimensional analysis, can only be important beyond mean field. More complicated behavior is expected to arise when further ionic species are added. However, for a certain parameter regime, we can demonstrate that the salt-free case can be mapped onto a corresponding system containing additional salt. The Green-Kubo formula for the electrophoretic mobility is derived, and its usefulness demonstrated by simulation data. Finally, we report on finite-element solutions of the electrokinetic equations, using the commercial software package COMSOL

  20. Novel imaging techniques for the nuclear microprobe

    Saint, A.

    1998-01-01

    Many of the developments of the scanning electron microscope (SEM) have been paralleled during the development of the scanning nuclear microprobe. Secondary electrons were used in the early development of both devices to provide specimen imaging due to the large numbers of secondaries produced per incident charged particle. Other imaging contrast techniques have also been developed on both machines. These include X-ray analysis, scattering contrast, transmission microscopy, channelling induced charge and others. The 'cross-section dependent' imaging techniques such as PIXE, RBS, NRA, etc., rely on the beam current on target for a given resolution. This has prompted research and development of brighter ion sources to maintain probe resolution at high beam current. Higher beam current bring problems with beam damage to the specimen. Low beam current techniques however rely on high countrate data collection systems, but this is only for spectroscopy. To produce an image we can increase beam currents to produce live-time images for specimen manipulation and observation. The work presented here will focus on some developments in live-time imaging with a nuclear micro probe that have taken place recently at the School of Physics, Microanalytical Research Centre (MARC), University of Melbourne

  1. Colloidal nematostatics

    V.M. Pergamenshchik

    2010-01-01

    Full Text Available We give a review of the theory of large distance colloidal interaction via the nematic director field. The new area of nematic colloidal systems (or nematic emulsions has been guided by the analogy between the colloidal nematostatics and electrostatics. The elastic charge density representation of the colloidal nematostatics [V.M. Pergamenshchik, V.O. Uzunova, Eur. Phys. J. E, 2007, 23, 161; Phys. Rev. E, 2007, 76, 011707] develops this analogy at the level of charge density and Coulomb interaction. The analogy is shown to lie in common mathematics based on the solutions of Laplace equation. However, the 3d colloidal nematostatics substantially differs from electrostatics both in its mathematical structure and physical implications. The elastic charge is a vector fully determined by the torque exerted upon colloid, the role of Gauss' theorem is played by conservation of the torque components. Elastic multipoles consist of two tensors (dyads. Formulas for the elastic multipoles, the Coulomb-like, dipole-dipole, and quadrupole-quadrupole pair interaction potentials are derived and illustrated by particular examples. Based on the tensorial structure, we list possible types of elastic dipoles and quadrupoles. An elastic dipole is characterized by its isotropic strength, anisotropy, chirality, and its longitudinal component. An elastic quadrupole can be uniaxial and biaxial. Relation between the multipole type and its symmetry is discussed, sketches of some types of multipoles are given. Using the mirror image method of electrostatics as a guiding idea, we develop the mirror image method in nematostatics for arbitrary director tilt at the wall. The method is applied to the charge-wall and dipole-wall interaction.

  2. Beam optics on the Melbourne proton microprobe

    Jamieson, D.N.; Colman, R.A.; Allan, G.L.; Legge, G.J.F.

    1985-01-01

    This review paper summarises results of ion optics development work conducted on the Melbourne Proton Microprobe and the associated Pelletron accelerator. The properties of a field ionization ion source have been investigated with the aim of replacing the existing R.F. ion source in the accelerator in order to obtain a brighter beam for the microprobe. The electrostatic emitter lens in the terminal of the accelerator has also been investigated with the aim of improving the focus of the accelerated beam. Finally, the aberrations of the probe forming lens system have been studied and it is shown how some of these may be corrected with an octupole lens

  3. A Theoretical Analysis of Colloid Attachment and Straining in Chemically Heterogeneous Porous Media

    Bradford, Scott A.; Torkzaban, Saeed; Shapiro, Alexander

    2013-01-01

    to attachment. In contrast, the effects of rc and q on Sf* were diminished by hr in comparison to attachment. Colloid immobilization adjacent to macroscopic roughness locations shares many similarities to grain–grain contact points and may be viewed as a type of straining process. In general, attachment...

  4. Charge characteristics of humic and fulvic acids: comparative analysis by colloid titration and potentiometric titration with continuous pK-distribution function model.

    Bratskaya, S; Golikov, A; Lutsenko, T; Nesterova, O; Dudarchik, V

    2008-09-01

    Charge characteristics of humic and fulvic acids of a different origin (inshore soils, peat, marine sediments, and soil (lysimetric) waters) were evaluated by means of two alternative methods - colloid titration and potentiometric titration. In order to elucidate possible limitations of the colloid titration as an express method of analysis of low content of humic substances we monitored changes in acid-base properties and charge densities of humic substances with soil depth, fractionation, and origin. We have shown that both factors - strength of acidic groups and molecular weight distribution in humic and fulvic acids - can affect the reliability of colloid titration. Due to deviations from 1:1 stoichiometry in interactions of humic substances with polymeric cationic titrant, the colloid titration can underestimate total acidity (charge density) of humic substances with domination of weak acidic functional groups (pK>6) and high content of the fractions with molecular weight below 1kDa.

  5. Colloidal superballs

    Rossi, L.

    2012-01-01

    This thesis is organized in four parts as follows. Part 1 focuses on the synthetic aspects of the colloidal model systems that will be used throughout the work described in this thesis. In Chapter 2 we describe synthetic procedures for the preparation of polycrystalline hematite superballs and

  6. Semi-Analysis for the Pseudo-Colloid Migration of Multi-member Decay Chains in the Fractured Porous Medium with the Flux Boundary

    Jeong, Mi Seon; Hwang, Yong Soo; Kang, Chul Hyung

    2010-01-01

    stationary solid wall surface of a fracture. Even though the colloid can not penetrate into the surrounding rock matrix, the solute diffuses into the porous matrix. In this analysis, the Laplace transformed solution is derived for a pseudo-colloid in a fracture and a solute in a fracture and a surrounding rock with a realistic inlet boundary condition. The canonical form solutions are used for the Fortran based a computational code which uses a special subroutine for the inversion of Laplace transform based on the Theory of Green. This new solution can be combined with the total system performance assessment code such as the Goldsim which can exchange the information such as the inlet concentration and the outlet flux with the newly developed code by using its dll file

  7. Retrospective analysis of cystic craniopharyngeomas after intracavital irradiation with yttrium-90 colloid

    Urbanova, E.; Vizda, J.; Netikova, M.; Kafka, P.; Jakubec, J.

    2002-01-01

    Aim: The authors report about follow up the patients after intracavitary irradiation for cystic craniopharyngeoma. Material and Methods: For retrospective analysis 15 patients were selected. The volume of the cyst was determined by CT or MRI. For dosimetry Backlund's formula was used. The cumulative dose to the inner surface of the cyst wall was about 250Gy. 90 Yttrium silicate colloid was administered directly during stereotactically (CT guided) surgery or through the Ommaya drainage system. Control scintigraphy was performed 2-3 hours after 90 Y injection with gamma camera to detect possible leakage of the radioisotope. None of our patients showed evidence of this. In addition to this, the patients were checked daily to pay attention to visual function, neurological condition and possible meningeal irritation. Results: Cyst shrinkage was monitored by repeated CT examinations. CT cyst volume measurement analysed all patients before and 1,2,3 and 5 years after the treatment. In our study 45% of cysts decreased in volume during 4 month, shrinkage of the initial cyst volume was 75% after 1 year. The cyst disappeared nearly totally in 5 patients. Only 3 cyst remain unchanged and 90 Y treatment was repeated. No patients developed a visual field defect or evidence of hypothalamic dysfunction after the treatment. The neuro-opthalmological state completely recovered in 2 patients and improved in 5 patients. The prognosis was good only when an intact optic discs in time of the treatment was present. In some cases the radioisotope was implanted at a late stage of the disease without the opthalmological and neurological improvement. One patient died due to pulmonary embolism one week after the procedure. One patient died within a one year of the treatment from complications related to a solid cystic recurrence. One of typical signs for recurrence was worsening of neuro-opthalmological state. Conclusion: From our results this intracavitary 90 Y therapy is minimally invasive

  8. Compartmental analysis of colloidal radiogold kinetics in liver and spleen of patients with hypersplenism

    Ristanovic, D.; Kostic, K.; Djokic, D.

    1979-01-01

    A mathematical model of colloidal substance kinetics in a five-compartment system is presented. If colloidal radioactive gold sup(198)Au is used, the model can be applied to the patient with enlarged and very active spleen. Radiogold activities in blood samples taken from patient's peripheral vein were measured. An indirect method of finding four out of five rate constants of the system is proposed. The facts presented by this study can be summarized as follows: in hypersplenism, the amount of radiogold, removed from the blood stream by the liver reticuloendothelial system, is about four times higher than the one coursing back from the liver through the hepatic vein into the systemic circulation. The radiogold amount, entering the liver in a given time, is twice as much as the substance amount passing from the systemic circulation to the spleen for the same period of time. The amount of the colloid injected before splenectomy is distributed in such a manner that, on an average, 60% is stored in liver and the rest, in the reticuloendothelial system of the spleen

  9. Colloid properties in groundwaters from crystalline formations

    Degueldre, C.A.

    1994-09-01

    Colloids are present in all groundwaters. The role they may play in the migration of safety-relevant radionuclides in the geosphere therefore must be studied. Colloid sampling and characterisation campaigns have been carried out in Switzerland. On the bases of the results from studies in the Grimsel area, Northern Switzerland and the Black Forest, as well as those obtained by other groups concerned with crystalline waters, a consistent picture is emerging. The groundwater colloids in crystalline formations are predominantly comprised of phyllosilicates and silica originating from the aquifer rock. Under constant hydrogeochemical conditions, the colloid concentration is not expected to exceed 100 ng.ml -1 when the calcium concentration is greater than 10 -4 . However, under transient chemical or physical conditions, such as geothermal or tectonic activity, colloid generation may be enhanced and the colloid concentration may reach 10 μg.ml -1 or more, if both the calcium and sodium concentrations are low. In the Nagra Crystalline Reference Water the expected colloid concentration is -1 . This can be compared, for example, to a colloid concentration of about 10 ng.ml -1 found in Zurzach water. The small colloid concentration in the reference water is a consequence of an attachment factor for clay colloids (monmorillonite) close to 1. A model indicates that at pH 8, the nuclide partition coefficients between water and colloid (K p ) must be smaller than 10 7 ml.g -1 if sorption takes place by surface complexation on colloids, = AIOH active groups forming the dominant sorption sites. This pragmatic model is based on the competition between the formation of nuclide hydroxo complexes in solution and their sorption on colloids. Experimental nuclide sorption data on colloids are compared with those obtained by applying this model. For a low colloid concentration, a sorption capacity of the order of 10 -9 M and reversible surface complexation, their presence in the

  10. Mixed beams for the nuclear microprobe

    Saint, A.; Breese, M.B.H.; Legge, G.L.F. [Melbourne Univ., Parkville, VIC (Australia). School of Physics

    1996-12-31

    Recently the Micro-Analytical Research Centre (MARC) at Melbourne University has developed a technique to provide mixed beams of ions for a magnetically focussed nuclear microprobe. Such a mixed beam is defined as two (or more) beams of different species ions that can quickly and easily be made to have the same magnetic rigidity R{sub m} = (mE/q{sup 2}) and therefore be transported, focused and scanned the same in a magnetic nuclear microprobe. The production of mixed beams in an electrostatically focussed micro- probe have already been demonstrated. This paper will show how mixed beams can be produced on a single-ended accelerator. Indications of how to produce them on a tandem will also be given. Applications of these mixed beams in micro-lithography, scanning transmission ion microscopy (STIM) imaging and ion beam induced charge (IBIC) imaging will also be presented. 3 refs., 3 figs.

  11. Mixed beams for the nuclear microprobe

    Saint, A; Breese, M B.H.; Legge, G L.F. [Melbourne Univ., Parkville, VIC (Australia). School of Physics

    1997-12-31

    Recently the Micro-Analytical Research Centre (MARC) at Melbourne University has developed a technique to provide mixed beams of ions for a magnetically focussed nuclear microprobe. Such a mixed beam is defined as two (or more) beams of different species ions that can quickly and easily be made to have the same magnetic rigidity R{sub m} = (mE/q{sup 2}) and therefore be transported, focused and scanned the same in a magnetic nuclear microprobe. The production of mixed beams in an electrostatically focussed micro- probe have already been demonstrated. This paper will show how mixed beams can be produced on a single-ended accelerator. Indications of how to produce them on a tandem will also be given. Applications of these mixed beams in micro-lithography, scanning transmission ion microscopy (STIM) imaging and ion beam induced charge (IBIC) imaging will also be presented. 3 refs., 3 figs.

  12. Biomedical application of the nuclear microprobe

    Lindh, U.

    1987-01-01

    The Studsvik Nuclear Microprobe (SMP) has mainly been devoted to applications in the biomedical field. Its ultimate resolution is reached at 2.9x2.9 μm 2 with a proton current of 100 pA. With this performance the SMP has been used in a wide range of disciplines covering environmental hygiene, toxicology, various aspects of internal medicine and trace element physiology. Examples of recent applications in these fields are described. (orig.)

  13. Development of a nuclear microprobe at IGCAR

    Ramesh, C.; Nair, K.G.M.; Thampi, N.S.; Saha, B.; Mathews, C.K.

    1988-01-01

    A nuclear microprobe is being developed at IGCAR. The system is being built to determine the profiles of light elements, specially carbon in clad and other structural materials of a fast breeder reactor. By scanning a focussed charged particle beam on the sample surface and by detecting the charged particle induced emissions, an elemental map of the surface is obtained. The paper gives the basic design considerations and present status. (author)

  14. Beam developments for the Harwell microprobe system

    Read, P.M.; Cookson, J.A.; Alton, G.D.

    1986-01-01

    A consequence of the rapid development of micron and submicron size electronic devices is the diminished applicability of high energy ion microprobes with their present resolution limitations to the study of such components. Although submicron beams have been reported the available beam current is barely sufficiently for PIXE and is not adequate for RBS. This lack of lateral resolution is due to low beam brightness at the microprobe object and aberrations in the focusing elements. As part of a program to address these problems the Harwell microprobe lens has been relocated on a new 5 MV Laddertron accelerator. The increased brightness and improved stability of this facility has so far led to a reduction in beam size from 3 x 3 μm 2 to about 2 x 2 μm 2 . The feasibility of using a liquid metal ion source has been examined with a view to achieving more substantial increases in brightness. While such sources have brightness approximately 10 5 times greater than conventional gaseous sources the highly divergent nature of the beam presents problems for the beam transport system. The use of a liquid metal source on the accelerator has been successfully demonstrated but it indicates the need for a special low aberration injection lens if brightness is to be maintained

  15. Chemical history with a nuclear microprobe

    Maggiore, C.J.; Benjamin, T.M.; Burnett, D.S.; Hyde, P.J.; Rogers, P.S.Z.; Srinivasan, S.; Tesmer, T.; Woolum, D.S.

    1983-01-01

    A nuclear microprobe cannot give direct information on the chemical state of an element, but the spatial distribution of elements in a specimen is often determined by the chemical history of the sample. Fuel cells and minerals are examples of complex systems whose elemental distributions are determined by past chemical history. The distribution of catalyst in used fuel cell electrodes provides direct information on the chemical stability of dispersed catalysts under operating conditions. The authors have used spatially resolved Rutherford backscattering to measure the migration of platinum and vanadium from intermetallic catalysts and to determine their suitability for use under the extreme operating conditions found in phosphoric acid fuel cells. Geologic materials are complex, heterogeneous samples with small mineral grains. The trace element distribution within the individual mineral grains and between different mineral phases is sensitive to the details of the mineral formation and history. The spatial resolution and sub-100-ppm sensitivity available with a nuclear microprobe open up several new classes of experiments to the geochemist. Geochemistry and electrochemistry are two areas proving particularly fruitful for application of the nuclear microprobe

  16. The new Schonland PIXE microprobe and applications to geological and archaeological samples

    Przybylowicz, W J; Watterson, J I.W.; Annegarn, H J; Connell, S H; Fearick, R W; Andeweg, A H; Sellschop, J P.F. [Schonland Research Centre for Nuclear Sciences, Univ. of the Witwatersrand, Johannesburg (South Africa)

    1993-04-01

    The new positive ion microprobe at the Schonland Centre is described and details are given of its configuration, its imaging system and software. In a unique configuration, the microprobe has access to two accelerators, a 6 MV EN tandem and a 2.5 MV single-ended machine. The imaging system uses a CAMAC based system and runs on a personal computer under OS/2. The implementation of PIXE and treatment of thick-target data are presented. Applications discussed are analysis of tin artifacts from the prehistory of metallurgy in South Africa; a diamond-containing rock; carbonado, gold contained in pyrite and cogenetic minerals included in diamond. (orig.).

  17. The new Schonland PIXE microprobe and applications to geological and archaeological samples

    Przybylowicz, W.J.; Watterson, J.I.W.; Annegarn, H.J.; Connell, S.H.; Fearick, R.W.; Andeweg, A.H.; Sellschop, J.P.F.

    1993-01-01

    The new positive ion microprobe at the Schonland Centre is described and details are given of its configuration, its imaging system and software. In a unique configuration, the microprobe has access to two accelerators, a 6 MV EN tandem and a 2.5 MV single-ended machine. The imaging system uses a CAMAC based system and runs on a personal computer under OS/2. The implementation of PIXE and treatment of thick-target data are presented. Applications discussed are analysis of tin artifacts from the prehistory of metallurgy in South Africa; a diamond-containing rock; carbonado, gold contained in pyrite and cogenetic minerals included in diamond. (orig.)

  18. Colloid migration in porous media

    Hunt, J.R.; McDowell-Boyer; Sitar, N.

    1985-01-01

    Retention of radionuclides for long periods near waste repositories depends upon multiple barriers, one of which is adsorption to immobile solid surfaces. Since small particles and colloidal matter have high adsorption capacities per unit mass and can be mobile in subsurface flows, colloidal transport of waste components requires analysis. Theories for predicting colloid migration through porous media have been developed in the filtration literature. The applicability of filtration theories for predicting particle and colloid transport. Emphasis is on suspended matter much smaller than pore sizes, where physical and chemical forces control migration rather than size dependent physical straining. In general, experimentally verifiable theories exist for particle filtration by clean media, and a sensitivity analysis is possible on particle and media properties and fluid flow rate. When particle aggregates accumulate within pores, media permeability decreases, resulting in flow field alteration and possible radionuclide isolation. An analysis of the limited experimental data available indicates that present theories cannot predict long-term colloid transport when permeability reduction occurs. The coupling of colloid attachment processes and the hydrologic flow processes requires more extensive laboratory field research than has currently been carried out. An emphasis on the fundamental mechanisms is necessary to enhance long-term predictability

  19. Stained glasses under the nuclear microprobe: A window into history

    Vilarigues, M. [Dep. de Conservacao e Restauro and R and D Unit Vidro e da Ceramica Para as Artes, FCT-UNL, Quinta da Torre, 2829-516 Caparica (Portugal)], E-mail: mgv@fct.unl.pt; Fernandes, P. [Dep. de Conservacao e Restauro and R and D Unit Vidro e da Ceramica Para as Artes, FCT-UNL, Quinta da Torre, 2829-516 Caparica (Portugal); Alves, L.C.; Silva, R.C. da [Dep. Fisica, LFI, ITN, E.N.10, 2686-953 Sacavem (Portugal)

    2009-06-15

    Stained glass fragments from the 15th, 16th and 20th centuries, belonging to Mosteiro de Santa Maria da Vitoria, Batalha (Portugal), were characterised non-destructively in a nuclear microprobe. The work aimed at finding the composition of the glasses and glass paintings and relating these with the corresponding production periods. The elemental compositions of the glass fragments were obtained by means of scanning micro-beam Particle Induced X-ray Emission ({mu}-PIXE) spectrometry in selected cross-sections. These were complemented by micro X-Ray fluorescence spectrometry. Characterisation of colour was performed by optical absorption spectroscopy in the UV-vis range, while the corrosion products were identified by optical microscopy and {mu}-FTIR (Fourier Transform Infra Red) spectroscopy in combination with the data generated by {mu}-PIXE. Nuclear microprobe analysis allowed unveiling the compositions and structures, in particular of glass paintings and corrosion products. While it is not surprising that Fe, Cu and Pb were the main elements identified in the grisaille paintings of all studied periods, as well as Ag and Cu found in the glasses decorated with yellow silver painting, their distribution gave important clues on the materials and techniques used to manufacture these stained glasses. Furthermore, it allowed establishing a definite relation between the compositions found and the periods of production, with the added bonus of correctly reassigning the manufacturing period of some samples.

  20. Tin accumulation in spermatozoa of the rats exposed to tributyltin chloride by synchrotron radiation X-ray fluorescence (SR-XRF) analysis with microprobe

    Homma-Takeda, S.; Nishimura, Y.; Terada, Y.; Ueno, S.; Watanabe, Y.; Yukawa, M.

    2005-01-01

    Organotin compounds are widely used in industry and its environmental contamination by these compounds has recently become a concern. It is known that they act as endocrine disruptors but details of the dynamics of Sn in reproductive organs are still unknown. In the present study, we attempted to determine Sn distribution in the testis of rats exposed to tributyltin chloride (TBTC) by inductively coupled argon plasma-mass spectrometry (ICP-MS) for microdissectioned seminiferous tubules and cell-selective metal determination of synchrotron radiation X-ray florescence (SR-XRF) analysis. TBTC was orally administered to rats at a dose of 45 μmol/kg per day for 3 days. One day later, Sn was detected in the microdissectioned seminiferous tubules at a level approximately equivalent to that in the testis. Significant stage-specificity of Sn accumulation was not observed in the experimental model. Sn was also detected in spermatozoa at the stage VIII seminiferous tubule, which are the final step of spermatogenesis in the testis. These data indicate that Sn accumulates in germ cells as well as in spermatozoa in a short period of TBTC exposure

  1. Tin accumulation in spermatozoa of the rats exposed to tributyltin chloride by synchrotron radiation X-ray fluorescence (SR-XRF) analysis with microprobe

    Homma-Takeda, S. [Environmental Radiation Protection Research Group, National Institute of Radiological Sciences, 4-9-1 Anagawa, Inage-ku Chiba 263-8555 (Japan)]. E-mail: shino_ht@nirs.go.jp; Nishimura, Y. [Environmental Radiation Protection Research Group, National Institute of Radiological Sciences, 4-9-1 Anagawa, Inage-ku Chiba 263-8555 (Japan); Terada, Y. [Japan Synchrotron Radiation Research Institute, Mikazuki, Hyogo 679-5198 (Japan); Ueno, S. [School of Veterinary Medicine and Animal Sciences, Kitasato University, Towada, Aomori 034-8628 (Japan); Watanabe, Y. [Environmental Radiation Protection Research Group, National Institute of Radiological Sciences, 4-9-1 Anagawa, Inage-ku Chiba 263-8555 (Japan); Yukawa, M. [Environmental Radiation Protection Research Group, National Institute of Radiological Sciences, 4-9-1 Anagawa, Inage-ku Chiba 263-8555 (Japan)

    2005-04-01

    Organotin compounds are widely used in industry and its environmental contamination by these compounds has recently become a concern. It is known that they act as endocrine disruptors but details of the dynamics of Sn in reproductive organs are still unknown. In the present study, we attempted to determine Sn distribution in the testis of rats exposed to tributyltin chloride (TBTC) by inductively coupled argon plasma-mass spectrometry (ICP-MS) for microdissectioned seminiferous tubules and cell-selective metal determination of synchrotron radiation X-ray florescence (SR-XRF) analysis. TBTC was orally administered to rats at a dose of 45 {mu}mol/kg per day for 3 days. One day later, Sn was detected in the microdissectioned seminiferous tubules at a level approximately equivalent to that in the testis. Significant stage-specificity of Sn accumulation was not observed in the experimental model. Sn was also detected in spermatozoa at the stage VIII seminiferous tubule, which are the final step of spermatogenesis in the testis. These data indicate that Sn accumulates in germ cells as well as in spermatozoa in a short period of TBTC exposure.

  2. In vivo analysis of tissue by Raman microprobe: examination of human skin lesions and esophagus Barrett's mucosa on an animal model

    Tfayli, Ali; Piot, Olivier; Derancourt, Sylvie; Cadiot, Guillaume; Diebold, Marie D.; Bernard, Philippe; Manfait, Michel

    2006-02-01

    In the last few years, Raman spectroscopy has been increasingly used for the characterization of normal and pathological tissues. A new Raman system, constituted of optic fibers bundle coupled to an axial Raman spectrometer (Horiba Jobin Yvon SAS), was developed for in vivo investigations. Here, we present in vivo analysis on two tissues: human skin and esophagus mucosa on a rat model. The skin is a directly accessible organ, representing a high diversity of lesions and cancers. Including malignant melanoma, basal cell carcinoma and the squamous cell carcinoma, skin cancer is the cancer with the highest incidence worldwide. Several Raman investigations were performed to discriminate and classify different types of skin lesions, on thin sections of biopsies. Here, we try to characterize in vivo the different types of skin cancers in order to be able to detect them in their early stages of development and to define precisely the exeresis limits. Barrett's mucosa was also studied by in vivo examination of rat's esophagus. Barrett's mucosa, induced by gastro-esophageal reflux, is a pretumoral state that has to be carefully monitored due to its high risk of evolution in adenocarcinoma. A better knowledge of the histological transformation of esophagus epithelium in a Barrett's type will lead to a more efficient detection of the pathology for its early diagnosis. To study these changes, an animal model (rats developing Barrett's mucosa after duodenum - esophagus anastomosis) was used. Potential of vibrational spectroscopy for Barrett's mucosa identification is assessed on this model.

  3. Anisotropic Model Colloids

    van Kats, C.M.

    2008-01-01

    The driving forces for fundamental research in colloid science are the ability to manage the material properties of colloids and to unravel the forces that play a role between colloids to be able to control and understand the processes where colloids play an important role. Therefore we are

  4. Colloid Transport and Retention

    Yuan, Hao; Shapiro, Alexander

    2012-01-01

    related to historical prospective, synthesis, characterization, theoretical modeling and application of unique class of colloidal materials starting from colloidal gold to coated silica colloid and platinum, titania colloids. This book is unique in its design, content, providing depth of science about...

  5. Microprobe to closely examine minerals

    2006-01-01

    The University of South Australia will develop synchrotron-based technology that can determine the structure and chemical composition of mineral samples at microscopic levels. The planned multi-analysis synchrotron X-ray facility Beam-line 11 is for implementing on the Australian Synchrotron. UniSA's Applied Centre for Structural and Synchrotron Studies (ACeSSS) will use Beamline 11 to shed new light on factors that constrain recoveries of copper and gold from typical copper ores. ACeSSS director Professor Andrea Gerson is working with an international team and the Australian Synchrotron on the design of Beamline 11. According to Gerson, there is scope to improve processing and/or increase recoveries in copper, gold and valueless pyrite either through separation, smelting, leaching or electro-processing. Using synchrotron technology, researchers will determine the structure and chemical composition of mineral samples to understand the fundamental behaviour of these materials in order to identify process and : environmental benefits. Three different strategies will be employed: tracing the movement of gold through the mineral processing chain to optimise and increase gold recovery; examining the surface layers formed when copper is leached from the mineral, chalcopyrite, to enhance the understanding of this surface layer formation and ultimately maximise cop-per recovery; and improving environmental remediation by understanding the mineralisation process during acid-rock drainage. ACeSSS will work with the minerals and environmental remediation sectors, building on the I establishment of the Cooperative Research Centre for Contamination Assessment and Remediation of the Environment, and cementing close collaboration with UniSA's Ian Wark Research Institute. Contributions from the SA Premier's Science and Research Fund, BHP Billiton and Rio Tinto, synchrotron partners Advanced Light Source (USA) and the Canadian Light Source Funding totalling $1.38m are available for

  6. Factorial analysis of the trihalomethane formation in the reaction of colloidal, hydrophobic, and transphilic fractions of DOM with free chlorine.

    Platikanov, Stefan; Tauler, Roma; Rodrigues, Pedro M S M; Antunes, Maria Cristina G; Pereira, Dilson; Esteves da Silva, Joaquim C G

    2010-09-01

    This study focuses on the factors that affect trihalomethane (THMs) formation when dissolved organic matter (DOM) fractions (colloidal, hydrophobic, and transphilic fractions) in aqueous solutions were disinfected with chlorine. DOM fractions were isolated and fractionated from filtered lake water and were characterized by elemental analysis. The investigation involved a screening Placket-Burman factorial analysis design of five factors (DOM concentration, chlorine dose, temperature, pH, and bromide concentration) and a Box-Behnken design for a detailed assessment of the three most important factor effects (DOM concentration, chlorine dose, and temperature). The results showed that colloidal fraction has a relatively low contribution to THM formation; transphilic fraction was responsible for about 50% of the chloroform generation, and the hydrophobic fraction was the most important to the brominated THM formation. When colloidal and hydrophobic fraction solutions were disinfected, the most significant factors were the following: higher DOM fraction concentration led to higher THM concentration, an increase of pH corresponded to higher concentration levels of chloroform and reduced bromoform, higher levels of chlorine dose and temperature produced a rise in the total THM formation, especially of the chlorinated THMs; higher bromide concentration generates higher concentrations of brominated THMs. Moreover, linear models were implemented and response surface plots were obtained for the four THM concentrations and their total sum in the disinfection solution as a function of the DOM concentration, chlorine dose, and temperature. Overall, results indicated that THM formation models were very complex due to individual factor effects and significant interactions among the factors. In order to reduce the concentration of THMs in drinking water, DOM concentrations must be reduced in the water prior to the disinfection. Fractionation of DOM, together with an elemental

  7. EDITORIAL: Colloidal suspensions Colloidal suspensions

    Petukhov, Andrei; Kegel, Willem; van Duijneveldt, Jeroen

    2011-05-01

    Special issue in honour of Henk Lekkerkerker's 65th birthday Professor Henk N W Lekkerkerker is a world-leading authority in the field of experimental and theoretical soft condensed matter. On the occasion of his 65th birthday in the summer of 2011, this special issue celebrates his many contributions to science. Henk Lekkerkerker obtained his undergraduate degree in chemistry at the University of Utrecht (1968) and moved to Calgary where he received his PhD in 1971. He moved to Brussels as a NATO fellow at the Université Libre de Bruxelles and was appointed to an assistant professorship (1974), an associate professorship (1977) and a full professorship (1980) in physical chemistry at the Vrije Universiteit Brussel. In 1985 he returned to The Netherlands to take up a professorship at the Van 't Hoff Laboratory, where he has been ever since. He has received a series of awards during his career, including the Onsager Medal (1999) of the University of Trondheim, the Bakhuys Roozeboom Gold Medal (2003) of the Royal Dutch Academy of Arts and Sciences (KNAW), the ECIS-Rhodia European Colloid and Interface Prize (2003), and the Liquid Matter Prize of the European Physical Society (2008). He was elected a member of KNAW in 1996, was awarded an Academy Chair position in 2005, and has held several visiting lectureships. Henk's work focuses on phase transitions in soft condensed matter, and he has made seminal contributions to both the theoretical and experimental aspects of this field. Here we highlight three major themes running through his work, and a few selected publications. So-called depletion interactions may lead to phase separation in colloid-polymer mixtures, and Henk realised that the partitioning of polymer needs to be taken into account to describe the phase behaviour correctly [1]. Colloidal suspensions can be used as model fluids, with the time- and length-scales involved leading to novel opportunities, notably the direct observation of capillary waves at a

  8. Microprobe investigation of brittle segregates in aluminum MIG and TIG welds

    Larssen, P. A.; Miller, E. L.

    1968-01-01

    Quantitative microprobe analysis of segregated particles in aluminum MIG /Metal Inert Gas/ and TIG /Tungsten Inert Gas/ welds indicated that there were about ten different kinds of particles, corresponding to ten different intermetallic compounds. Differences between MIG and TIG welds related to the individual cooling rates of these welds.

  9. Evaluation of an x-ray microprobe technique as a possible aid to detect salmonellae

    Richter, E.R.; Banwart, G.J.

    1982-01-01

    Specific bacterial antigen (Salmonella) increased in phosphorus and sqlfur after reaction with the flukrescain isothiocyanate-tagged anti-Salmonella antibody, while nonspecific antigen (Escherichia coli) did not. X-ray microprobe analysis may be useful in detecting salmonellae or other bacteria by determining increases in the elemental constituents of bacterial cells when reacted with elemental-tagged antibodies

  10. Elemental microanalysis of biological and medical specimens with a scanning proton microprobe

    Legge, G.J.F.; Mazzolini, A.P.

    1979-01-01

    The scanning proton microprobe is shown to be a sensitive instrument for elemental microanalysis of cells and tissues in biological and medical specimens. The preparation of specimens and their behaviour under irradiation are crucial and the application of quantitative scanning analysis to the monitoring of such problems is illustrated

  11. Numerical and experimental analysis of the sedimentation of spherical colloidal suspensions under centrifugal force

    Antonopoulou, Evangelia; Rohmann-Shaw, Connor F.; Sykes, Thomas C.; Cayre, Olivier J.; Hunter, Timothy N.; Jimack, Peter K.

    2018-03-01

    Understanding the sedimentation behaviour of colloidal suspensions is crucial in determining their stability. Since sedimentation rates are often very slow, centrifugation is used to expedite sedimentation experiments. The effect of centrifugal acceleration on sedimentation behaviour is not fully understood. Furthermore, in sedimentation models, interparticle interactions are usually omitted by using the hard-sphere assumption. This work proposes a one-dimensional model for sedimentation using an effective maximum volume fraction, with an extension for sedimentation under centrifugal force. A numerical implementation of the model using an adaptive finite difference solver is described. Experiments with silica suspensions are carried out using an analytical centrifuge. The model is shown to be a good fit with experimental data for 480 nm spherical silica, with the effects of centrifugation at 705 rpm studied. A conversion of data to Earth gravity conditions is proposed, which is shown to recover Earth gravity sedimentation rates well. This work suggests that the effective maximum volume fraction accurately captures interparticle interactions and provides insights into the effect of centrifugation on sedimentation.

  12. Colloids versus crystalloids in objective-guided fluid therapy, systematic review and meta-analysis. Too early or too late to draw conclusions

    Javier Ripollés

    2015-08-01

    Full Text Available INTRODUCTION: Several clinical trials on Goal directed fluid therapy (GDFT were carried out, many of those using colloids in order to optimize the preload. After the decision of European Medicines Agency, there is such controversy regarding its use, benefits, and possible contribution to renal failure. The objective of this systematic review and meta-analysis is to compare the use of last-generation colloids, derived from corn, with crystalloids in GDFT to determine associated complications and mortality.METHODS: A bibliographic research was carried out in MEDLINE PubMed, EMBASE and Cochrane Library, corroborating randomized clinical trials where crystalloids are compared to colloids in GDFT for major non-cardiac surgery in adults.RESULTS: One hundred thirty references were found and among those 38 were selected and 29 analyzed; of these, six were included for systematic review and meta-analysis, including 390 patients. It was observed that the use of colloids is not associated with the increase of complications, but rather with a tendency to a higher mortality (RR [95% CI] 3.87 [1.121-13.38]; I2 = 0.0%; p = 0.635.CONCLUSIONS: Because of the limitations of this meta-analysis due to the small number of randomized clinical trials and patients included, the results should be taken cautiously, and the performance of new randomized clinical trials is proposed, with enough statistical power, comparing balanced and unbalanced colloids to balanced and unbalanced crystalloids, following the protocols of GDFT, considering current guidelines and suggestions made by groups of experts.

  13. A new scanning proton microprobe with long focus

    Zhu Jieqing; Li Minqian; Mao Yu; Chen Hanmin; Gu Yingmei; Yang Changyi; Sheng Kanglong

    1991-01-01

    A new scanning proton microprobe equipped with a long focus Russian magnetic quadruplet is set up. With excellent performances of ion optics, it can be used to do experiments of PIXE, RBS, RFS, NRA and channelling simultaneously within a micron-region. The power supplies for quadruplet and scanning coils are controlled by an IBM-PC computer and a scanning graphical monitor based on an Apple IIe microcomputer provides convenience of searching for an interesting area to scan. The advanced modes of the fast random scan and the event-by-event data collection make it possible to treat the multi-parameter and multi-detector data by means of the strategy of TQSA (Total quantitative scanning analysis). There are three types of graphical display including the innovation of three dimensional contour mapping

  14. Nuclear microprobe imaging of gallium nitrate in cancer cells

    Ortega, Richard; Suda, Asami; Devès, Guillaume

    2003-09-01

    Gallium nitrate is used in clinical oncology as treatment for hypercalcemia and for cancer that has spread to the bone. Its mechanism of antitumor action has not been fully elucidated yet. The knowledge of the intracellular distribution of anticancer drugs is of particular interest in oncology to better understand their cellular pharmacology. In addition, most metal-based anticancer compounds interact with endogenous trace elements in cells, altering their metabolism. The purpose of this experiment was to examine, by use of nuclear microprobe analysis, the cellular distribution of gallium and endogenous trace elements within cancer cells exposed to gallium nitrate. In a majority of cellular analyses, gallium was found homogeneously distributed in cells following the distribution of carbon. In a smaller number of cells, however, gallium appeared concentrated together with P, Ca and Fe within round structures of about 2-5 μm diameter located in the perinuclear region. These intracellular structures are typical of lysosomial material.

  15. Nuclear microprobe imaging of gallium nitrate in cancer cells

    Ortega, Richard; Suda, Asami; Deves, Guillaume

    2003-01-01

    Gallium nitrate is used in clinical oncology as treatment for hypercalcemia and for cancer that has spread to the bone. Its mechanism of antitumor action has not been fully elucidated yet. The knowledge of the intracellular distribution of anticancer drugs is of particular interest in oncology to better understand their cellular pharmacology. In addition, most metal-based anticancer compounds interact with endogenous trace elements in cells, altering their metabolism. The purpose of this experiment was to examine, by use of nuclear microprobe analysis, the cellular distribution of gallium and endogenous trace elements within cancer cells exposed to gallium nitrate. In a majority of cellular analyses, gallium was found homogeneously distributed in cells following the distribution of carbon. In a smaller number of cells, however, gallium appeared concentrated together with P, Ca and Fe within round structures of about 2-5 μm diameter located in the perinuclear region. These intracellular structures are typical of lysosomial material

  16. Colloid formation in groundwater by subsurface aeration: characterisation of the geo-colloids and their counterparts

    Wolthoorn, Anke; Temminghoff, Erwin J.M.; Riemsdijk, Willem H. van

    2004-01-01

    Subsurface aeration is used to oxidise Fe in situ in groundwater to make the water potable. In a groundwater system with pH > 7, subsurface aeration results in a non-mobile Fe precipitate and mobile Fe colloids. Since originally the goal of subsurface aeration is to remove Fe in situ, the formation of non-mobile Fe precipitate is the desired result. In addition to this intended effect, subsurface aeration may also strongly enhance the microbiological removal of NH 4 in the purification station. A hypothesis is that mobile Fe colloids may be the link between subsurface aeration and the positive effect on the microbiological removal of NH 4 . The objective of this study is to characterise the mobile Fe colloids and to derive a synthetic substitute for the naturally formed Fe colloids in order to be able to apply the Fe colloids as a management tool to enhance the removal of NH 4 in the process of producing drinking water from groundwater. At a purification station in The Netherlands natural Fe colloids from an aerated well were sampled. Furthermore, eight synthetic Fe colloids were prepared by oxidising synthetic solutions differing in elemental composition. The colloids were analysed using chemical analysis and electron microscopy (SEM and SEM-EDAX). The Fe colloids sampled in the field contained Fe, Ca, Na, PO 4 and Mn. Also in the synthetic Fe colloids PO 4 , Ca, Na and Mn were the most important elements next to Fe. Phosphate and dissolved organic C strongly influenced the morphology of the synthetic Fe colloids. When both the elemental composition and the morphology of the Fe colloids are taken into account, the synthetic Fe colloids formed in the synthetic solution containing Fe, Mn, PO 4 , SiO 4 and dissolved organic matter best match the Fe colloids from the field

  17. Colloid formation in groundwater by subsurface aeration: characterisation of the geo-colloids and their counterparts

    Wolthoorn, Anke; Temminghoff, Erwin J.M.; Riemsdijk, Willem H. van

    2004-09-01

    Subsurface aeration is used to oxidise Fe in situ in groundwater to make the water potable. In a groundwater system with pH > 7, subsurface aeration results in a non-mobile Fe precipitate and mobile Fe colloids. Since originally the goal of subsurface aeration is to remove Fe in situ, the formation of non-mobile Fe precipitate is the desired result. In addition to this intended effect, subsurface aeration may also strongly enhance the microbiological removal of NH{sub 4} in the purification station. A hypothesis is that mobile Fe colloids may be the link between subsurface aeration and the positive effect on the microbiological removal of NH{sub 4}. The objective of this study is to characterise the mobile Fe colloids and to derive a synthetic substitute for the naturally formed Fe colloids in order to be able to apply the Fe colloids as a management tool to enhance the removal of NH{sub 4} in the process of producing drinking water from groundwater. At a purification station in The Netherlands natural Fe colloids from an aerated well were sampled. Furthermore, eight synthetic Fe colloids were prepared by oxidising synthetic solutions differing in elemental composition. The colloids were analysed using chemical analysis and electron microscopy (SEM and SEM-EDAX). The Fe colloids sampled in the field contained Fe, Ca, Na, PO{sub 4} and Mn. Also in the synthetic Fe colloids PO{sub 4}, Ca, Na and Mn were the most important elements next to Fe. Phosphate and dissolved organic C strongly influenced the morphology of the synthetic Fe colloids. When both the elemental composition and the morphology of the Fe colloids are taken into account, the synthetic Fe colloids formed in the synthetic solution containing Fe, Mn, PO{sub 4}, SiO{sub 4} and dissolved organic matter best match the Fe colloids from the field.

  18. Proton microprobe study of tin-polymetallic deposits

    Murao, S. [Geological Survey of Japan, Tsukuba, Ibaraki (Japan); Sie, S.H.; Suter, G.F. [Commonwealth Scientific and Industrial Research Organisation (CSIRO), North Ryde, NSW (Australia). Div. of Exploration Geoscience

    1996-12-31

    Tin-polymetallic vein type deposits are a complex mixture of cassiterite and sulfides and they are the main source of technologically important rare metals such as indium and bismuth. Constituent minerals are usually fine grained having wide range of chemical composition and often the elements of interest occur as trace elements not amenable to electron microprobe analysis. PIXE with a proton microprobe can be an effective tool to study such deposits by delineating the distribution of trace elements among carrier minerals. Two representative indium-bearing deposits of tin- polymetallic type, Tosham of India (Cu-ln-Bi-Sn-W-Ag), and Mount Pleasant of Canada (Zn-Cu-In-Bi-Sn-W), were studied to delineate the distribution of medical/high-tech rare metals and to examine the effectiveness of the proton probe analysis of such ore. One of the results of the study indicated that indium and bismuth are present in chalcopyrite in the deposits. In addition to these important rare metals, zinc, copper, arsenic, antimony, selenium, and tin are common in chalcopyrite and pyrite. Arsenopyrite contains nickel, copper, zinc, silver, tin, antimony and bismuth. In chalcopyrite and pyrite, zinc, arsenic, indium, bismuth and lead are richer in Mount Pleasant ore, but silver is higher at Tosham. Also thallium and gold were found only in Tosham pyrite. The Tosham deposit is related to S-type granite, while Mount Pleasant to A-type. It appears that petrographic character of the source magma is one of the factors to determine the trace element distribution in tin-polymetallic deposit. 6 refs., 2 figs.

  19. Proton microprobe study of tin-polymetallic deposits

    Murao, S [Geological Survey of Japan, Tsukuba, Ibaraki (Japan); Sie, S H; Suter, G F [Commonwealth Scientific and Industrial Research Organisation (CSIRO), North Ryde, NSW (Australia). Div. of Exploration Geoscience

    1997-12-31

    Tin-polymetallic vein type deposits are a complex mixture of cassiterite and sulfides and they are the main source of technologically important rare metals such as indium and bismuth. Constituent minerals are usually fine grained having wide range of chemical composition and often the elements of interest occur as trace elements not amenable to electron microprobe analysis. PIXE with a proton microprobe can be an effective tool to study such deposits by delineating the distribution of trace elements among carrier minerals. Two representative indium-bearing deposits of tin- polymetallic type, Tosham of India (Cu-ln-Bi-Sn-W-Ag), and Mount Pleasant of Canada (Zn-Cu-In-Bi-Sn-W), were studied to delineate the distribution of medical/high-tech rare metals and to examine the effectiveness of the proton probe analysis of such ore. One of the results of the study indicated that indium and bismuth are present in chalcopyrite in the deposits. In addition to these important rare metals, zinc, copper, arsenic, antimony, selenium, and tin are common in chalcopyrite and pyrite. Arsenopyrite contains nickel, copper, zinc, silver, tin, antimony and bismuth. In chalcopyrite and pyrite, zinc, arsenic, indium, bismuth and lead are richer in Mount Pleasant ore, but silver is higher at Tosham. Also thallium and gold were found only in Tosham pyrite. The Tosham deposit is related to S-type granite, while Mount Pleasant to A-type. It appears that petrographic character of the source magma is one of the factors to determine the trace element distribution in tin-polymetallic deposit. 6 refs., 2 figs.

  20. Proton microprobe study of tin-polymetallic deposits

    Murao, S.; Sie, S.H.; Suter, G.F.

    1996-01-01

    Tin-polymetallic vein type deposits are a complex mixture of cassiterite and sulfides and they are the main source of technologically important rare metals such as indium and bismuth. Constituent minerals are usually fine grained having wide range of chemical composition and often the elements of interest occur as trace elements not amenable to electron microprobe analysis. PIXE with a proton microprobe can be an effective tool to study such deposits by delineating the distribution of trace elements among carrier minerals. Two representative indium-bearing deposits of tin- polymetallic type, Tosham of India (Cu-ln-Bi-Sn-W-Ag), and Mount Pleasant of Canada (Zn-Cu-In-Bi-Sn-W), were studied to delineate the distribution of medical/high-tech rare metals and to examine the effectiveness of the proton probe analysis of such ore. One of the results of the study indicated that indium and bismuth are present in chalcopyrite in the deposits. In addition to these important rare metals, zinc, copper, arsenic, antimony, selenium, and tin are common in chalcopyrite and pyrite. Arsenopyrite contains nickel, copper, zinc, silver, tin, antimony and bismuth. In chalcopyrite and pyrite, zinc, arsenic, indium, bismuth and lead are richer in Mount Pleasant ore, but silver is higher at Tosham. Also thallium and gold were found only in Tosham pyrite. The Tosham deposit is related to S-type granite, while Mount Pleasant to A-type. It appears that petrographic character of the source magma is one of the factors to determine the trace element distribution in tin-polymetallic deposit. 6 refs., 2 figs

  1. Combination of synchrotron radiation X-ray microprobe and nuclear microprobe for chromium and chromium oxidation states quantitative mapping in single cells

    Ortega, Richard; Deves, Guillaume; Fayard, Barbara; Salome, Murielle; Susini, Jean

    2003-01-01

    Hexavalent chromium compounds are established carcinogens but their mechanism of cell transformation has not been elucidated yet. In this study, chromium oxidation state distribution maps in cells exposed to soluble (Na 2 CrO 4 ), or insoluble (PbCrO 4 ), Cr(VI) compounds have been obtained by use of the ESRF ID-21 X-ray microscope. In addition, the quantitative maps of element distributions in cells have been determined using the nuclear microprobe of Bordeaux-Gradignan. Nuclear microprobe quantitative analysis revealed interesting features on chromium, and lead, cellular uptake. It is suggested that cells can enhance PbCrO 4 solubility, resulting in chromium, but not lead uptake. The differential carcinogenic potential of soluble and insoluble Cr(VI) compounds is discussed with regard to chromium intracellular quantitative distribution

  2. The new scanning nuclear microprobe in Uppsala

    Sunde, T.; Nystroem, J.; Lindh, U.

    1991-01-01

    During 1989/90 a scanning microprobe, developed for 2-4 MeV protons and submicron resolution, is being installed at the EN-tandem accelerator at the The Svedberg Laboratory, Uppsala University, Sweden. The probe-forming units (object diaphragm, aperture diaphragm and triplet of spark-eroded quadrupoles), the scanning unit of current-controlled ferrite cores and a current digitizer are of Oxford design. The other parts are commercial products or are constructed by ourselves. The latter includes the equipment for optical alignment by interference, a feedback-controlled magnetic beam steerer and stabiliser, a fast beam deflector, specially designed mechanical vibration reducers and dedicated AT expansion cards for scanning control and data acquisition. (orig.)

  3. Colloid-Associated Radionuclide Concentration Limits: ANL

    Mertz, C.

    2000-01-01

    The purpose and scope of this report is to describe the analysis of available colloidal data from waste form corrosion tests at Argonne National Laboratory (ANL) to extract characteristics of these colloids that can be used in modeling their contribution to the source term for sparingly soluble radioelements (e.g., Pu). Specifically, the focus is on developing a useful description of the following waste form colloid characteristics: (1) composition, (2) size distribution, and (3) quantification of the rate of waste form colloid generation. The composition and size distribution information are intended to support analysis of the potential transport of the sparingly soluble radionuclides associated with the waste form colloids. The rate of colloid generation is intended to support analysis of the waste form colloid-associated radionuclide concentrations. In addressing the above characteristics, available data are interpreted to address mechanisms controlling colloid formation and stability. This report was developed in accordance with the ''Technical Work Plan for Waste Form Degradation Process Model Report for SR'' (CRWMS M and O 2000). Because the end objective is to support the source term modeling we have organized the conclusions into two categories: (1) data analysis conclusions and (2) recommendations for colloid source term modeling. The second category is included to facilitate use of the conclusions from the data analysis in the abstraction of a colloid source term model. The data analyses and conclusions that are presented in this report are based on small-scale laboratory tests conducted on a limited number of waste glass compositions and spent fuel types

  4. Applications of nuclear microprobes in the semiconductor industry

    Takai, M.

    1996-01-01

    Possible nuclear microprobe applications in semiconductor industries are discussed. A unique technique using soft-error mapping and ion beam induced current measurements for reliability testing of dynamic random access memories such as soft-error immunity and noise carrier suppression has been developed for obtaining design parameters of future memory devices. Nano-probes and small installation areas are required for the use of microprobes in the semiconductor industry. Issues arising from microprobe applications such as damage induced by the probe beam are clarified. (orig.)

  5. Total quantitative recording of elemental maps and spectra with a scanning microprobe

    Legge, G.J.F.; Hammond, I.

    1979-01-01

    A system of data recording and analysis has been developed by means of which simultaneously all data from a scanning instrument such as a microprobe can be quantitatively recorded and permanently stored, including spectral outputs from several detectors. Only one scanning operation is required on the specimen. Analysis is then performed on the stored data, which contain quantitative information on distributions of all elements and spectra of all regions

  6. Evaluation of Colloid Retention Site Dominance in Variably Saturated Porous Media: An All Pores Pore-Scale Analysis

    Morales, Veronica; Perez-Reche, Francisco; Holzner, Markus; Kinzelbach, Wolfgang

    2016-04-01

    It is well accepted that colloid and nanoparticle transport processes in porous media differ substantially between water saturated and unsaturated conditions. Differences are frequently ascribed to particle immobilization by association with interfaces with the gas, as well as to restrictions of the liquid medium through which colloids are transported. Yet, the current understanding of the importance of particle retention at gas interfaces is based on observations of single pores or two-dimensional pore network representations, leaving open the question of their statistical significance when all pores in the medium are considered. In order to address this question, column experiments were performed using a model porous medium of glass beads through which Silver particles were transported for conditions of varying water content and water chemistry. X-ray microtomography was subsequently employed as a non-destructive imaging technique to obtain pore-scale information of the entire column regarding: i) the presence and distribution of the main locations where colloids can become retained (interfaces with the water-solid, air-water, air-solid, and air-water-solid, grain-grain contacts, and the bulk liquid), ii) deposition profiles of colloids along the column classified by the available retention location, and iii) channel widths of 3-dimensional pore-water network representations. The results presented provide a direct statistical evaluation on the significance of colloid retention by attachment to interfaces or by strainig at contact points where multiple interfaces meet.

  7. Determination of trace element mineral/liquid partition coefficients in melilite and diopside by ion and electron microprobe techniques

    Kuehner, S. M.; Laughlin, J. R.; Grossman, L.; Johnson, M. L.; Burnett, D. S.

    1989-01-01

    The applicability of ion microprobe (IMP) for quantitative analysis of minor elements (Sr, Y, Zr, La, Sm, and Yb) in the major phases present in natural Ca-, Al-rich inclusions (CAIs) was investigated by comparing IMP results with those of an electron microprobe (EMP). Results on three trace-element-doped glasses indicated that it is not possible to obtain precise quantitative analysis by using IMP if there are large differences in SiO2 content between the standards used to derive the ion yields and the unknowns.

  8. Elemental microanalysis of botanical specimens using the Melbourne Proton Microprobe

    Mazzolini, A.P.J.; Legge, G.J.F.

    1978-01-01

    A proton microprobe has been used to obtain the distribution of elements of various botanical specimens. This paper presents preliminary results obtained by the irradiation of certain organs of the wheat plant

  9. Optimization of the electrostatic structure of the ion microprobe

    I. G. Ignat'ev

    2012-03-01

    Full Text Available The paper presents optimization data obtained for an immersion probe-forming system of the ion microprobe to be used in 3 MeV H+ ion accelerator generating 0,4 μm beam spot for normalized acceptance of 7 μm2 · mrad2 · MeV. To achieve higher microprobe resolution it is intended to place an electrostatic lens between the collimators and the accelerating tube.

  10. Subgroup report on hard x-ray microprobes

    Ice, G.E.; Barbee, T.; Bionta, R.; Howells, M.; Thompson, A.C.; Yun, W.

    1994-01-01

    The increasing availability of synchrotron x-ray sources has stimulated the development of advanced hard x-ray (E≥5 keV) microprobes. New x-ray optics have been demonstrated which show promise for achieving intense submicron hard x-ray probes. These probes will be used for extraordinary elemental detection by x-ray fluorescence/absorption and for microdiffraction to identify phase and strain. The inherent elemental and crystallographic sensitivity of an x-ray microprobe and its inherently nondestructive and penetrating nature makes the development of an advanced hard x-ray microprobe an important national goal. In this workshop state-of-the-art hard x-ray microprobe optics were described and future directions were discussed. Gene Ice, Oak Ridge National Laboratory (ORNL), presented an overview of the current status of hard x-ray microprobe optics and described the use of crystal spectrometers to improve minimum detectable limits in fluorescent microprobe experiments. Al Thompson, Lawrence Berkeley Laboratory (LBL), described work at the Center for X-ray Optics to develop a hard x-ray microprobe based on Kirkpatrick-Baez (KB) optics. Al Thompson also showed the results of some experimental measurements with their KB optics. Malcolm Howells presented a method for bending elliptical mirrors and Troy Barbee commented on the use of graded d spacings to achieve highest efficiency in KB multilayer microfocusing. Richard Bionta, Lawrence Livermore National Laboratory (LLNL), described the development of the first hard x-ray zone plates and future promise of so called open-quotes jelly rollclose quotes or sputter slice zone plates. Wenbing Yun, Argonne National Laboratory (ANL), described characterization of jelly roll and lithographically produced zone plates and described the application of zone plates to focus extremely narrow bandwidths by nuclear resonance. This report summarizes the presentations of the workshop subgroup on hard x-ray microprobes

  11. The new nuclear microprobe at Livermore

    Roberts, M.L.; Bench, G.S.; Heikkinen, D.W.; Morse, D.H.; Bach, P.R.; Pontau, A.E.

    1994-10-01

    Lawrence Livermore National Laboratory (LLNL) and Sandia National Laboratories/California have jointly constructed a new nuclear microprobe beamline. This beamline is located on the LLNL 10 MV tandem accelerator and can be used for multidisciplinary research using PIXE, PIGE, energy loss tomography, or IBS techniques. Distinctive features of the beamline include incorporation of magnet power supplies into the accelerator control system, computer controlled object and image slits, automated target positioning to sub-micron resolution, and video optics for beam positioning and observation. Mitigation of vibrations was accomplished with vibration isolators and a rigid beamline design while integral beamline shielding was used to shield from stray magnetic fields. Available detectors include a wavelength dispersive X-ray spectrometer, a High-Purity Germanium detector (HPGe), a Lithium-Drifted Silicon X-Ray detector (SiLi), and solid state surface barrier detectors. Along with beamline performance, results from recent measurements on determination of trace impurities in an International Thermonuclear Experimental Reactor (ITER) super conducting wire strand, determination of Ca/Sr ratios in seashells, and determination of minor and trace element concentrations in sperm cells are presented

  12. The INS nuclear microprobe and its application

    Coote, G.E.

    1986-01-01

    The nuclear microprobe directs a well-focused beam of high-energy protons or deuterons at a solid specimen inside a vacuum chamber. Atomic and nuclear reactions are induced in those elements in a layer about 20 micro m thick, leading to the emission of characteristic x-rays, gamma rays, and charged particles as well as Rutherford scattering of the incident beam. These radiations impinge on several detectors near the specimen (NaI, Ge(Li), Si(Li) and Si surface barrier). Using proton-excited x-rays all elements above Na may be detected with sensitivities 10 or 100 times that of the electron probe, while elements which can be estimated from their gamma rays include C, N, O, F, Na and Al. In most of our projects the distribution of a trace or minor element (e.g. F, N) is compared to that of a major element (e.g. Ca or Fe). Recent areas of application include archaeometry (diffusion profiles of F in bones and teeth; depth profiles of sodium in obsidian), geology (F concentrations in mineral grains; studies of the Cretaceous-Tertiary boundary), metallurgy (C, O, N in steel and in welds; S, O, C in corrosion layers), fisheries management (Zn, Sr in otoliths; F in dogfish fin spines and vertebrae), biology (Fe, Sr, N in egg shells; trace elements in human hair), and dental research

  13. Deep Space 2: The Mars Microprobe Mission

    Smrekar, Suzanne; Catling, David; Lorenz, Ralph; Magalhães, Julio; Moersch, Jeffrey; Morgan, Paul; Murray, Bruce; Presley-Holloway, Marsha; Yen, Albert; Zent, Aaron; Blaney, Diana

    The Mars Microprobe Mission will be the second of the New Millennium Program's technology development missions to planetary bodies. The mission consists of two penetrators that weigh 2.4 kg each and are being carried as a piggyback payload on the Mars Polar Lander cruise ring. The spacecraft arrive at Mars on December 3, 1999. The two identical penetrators will impact the surface at ~190 m/s and penetrate up to 0.6 m. They will land within 1 to 10 km of each other and ~50 km from the Polar Lander on the south polar layered terrain. The primary objective of the mission is to demonstrate technologies that will enable future science missions and, in particular, network science missions. A secondary goal is to acquire science data. A subsurface evolved water experiment and a thermal conductivity experiment will estimate the water content and thermal properties of the regolith. The atmospheric density, pressure, and temperature will be derived using descent deceleration data. Impact accelerometer data will be used to determine the depth of penetration, the hardness of the regolith, and the presence or absence of 10 cm scale layers.

  14. Study of ion tracks by micro-probe ion energy loss spectroscopy

    Vacík, Jiří; Havránek, Vladimír; Hnatowicz, Vladimír; Horák, Pavel; Fink, Dietmar; Apel, P. Yu.

    2014-01-01

    Roč. 332, AUG (2014), s. 308-311 ISSN 0168-583X. [21st International Conference on Ion Beam Analysis (IBA). Seattle, 23.06.2013-28.06.2013] R&D Projects: GA ČR(CZ) GBP108/12/G108; GA MŠk(XE) LM2011019 Institutional support: RVO:61389005 Keywords : ion energy loss spectrometry * single ion track * microprobe * tomography Subject RIV: BM - Solid Matter Physics ; Magnetism Impact factor: 1.124, year: 2014

  15. Quantitative elemental imaging of octopus stylets using PIXE and the nuclear microprobe

    Doubleday, Zoe [Marine Research Laboratories, Tasmanian Aquaculture and Fisheries Institute, University of Tasmania, Private Bag 49, Tasmania 7001 (Australia)], E-mail: zoeanned@utas.edu.au; Belton, David [CSIRO Exploration and Mining, University of Melbourne (School of Physics), Melbourne 3010 (Australia); Pecl, Gretta; Semmens, Jayson [Marine Research Laboratories, Tasmanian Aquaculture and Fisheries Institute, University of Tasmania, Private Bag 49, Tasmania 7001 (Australia)

    2008-01-15

    By utilising targeted microprobe technology, the analysis of elements incorporated within the hard bio-mineralised structures of marine organisms has provided unique insights into the population biology of many species. As hard structures grow, elements from surrounding waters are incorporated effectively providing a natural 'tag' that is often unique to the animal's particular location or habitat. The spatial distribution of elements within octopus stylets was investigated, using the nuclear microprobe, to assess their potential for determining dispersal and population structure in octopus populations. Proton Induced X-ray Emission (PIXE) was conducted using the Dynamic Analysis method and GeoPIXE software package, which produced high resolution, quantitative elemental maps of whole stylet cross-sections. Ten elements were detected within the stylets which were heterogeneously distributed throughout the microstructure. Although Ca decreased towards the section edge, this trend was consistent between individuals and remained homogeneous in the inner region of the stylet, and thus appears a suitable internal standard for future microprobe analyses. Additional analyses used to investigate the general composition of the stylet structure suggested that they are amorphous and largely organic, however, there was some evidence of phosphatic mineralisation. In conclusion, this study indicates that stylets are suitable for targeted elemental analysis, although this is currently limited to the inner hatch region of the microstructure.

  16. Quantitative elemental imaging of octopus stylets using PIXE and the nuclear microprobe

    Doubleday, Zoe; Belton, David; Pecl, Gretta; Semmens, Jayson

    2008-01-01

    By utilising targeted microprobe technology, the analysis of elements incorporated within the hard bio-mineralised structures of marine organisms has provided unique insights into the population biology of many species. As hard structures grow, elements from surrounding waters are incorporated effectively providing a natural 'tag' that is often unique to the animal's particular location or habitat. The spatial distribution of elements within octopus stylets was investigated, using the nuclear microprobe, to assess their potential for determining dispersal and population structure in octopus populations. Proton Induced X-ray Emission (PIXE) was conducted using the Dynamic Analysis method and GeoPIXE software package, which produced high resolution, quantitative elemental maps of whole stylet cross-sections. Ten elements were detected within the stylets which were heterogeneously distributed throughout the microstructure. Although Ca decreased towards the section edge, this trend was consistent between individuals and remained homogeneous in the inner region of the stylet, and thus appears a suitable internal standard for future microprobe analyses. Additional analyses used to investigate the general composition of the stylet structure suggested that they are amorphous and largely organic, however, there was some evidence of phosphatic mineralisation. In conclusion, this study indicates that stylets are suitable for targeted elemental analysis, although this is currently limited to the inner hatch region of the microstructure

  17. Environmental applications of the LANL nuclear microprobe

    Hickmott, D.D.; Herrin, J.M.; Abell, R.; George, M.; Gauerke, E.R.; Denniston, R.F.

    1997-01-01

    The LANL nuclear microprobe has been used to study the distributions of trace elements (TE) of environmental interest including: (1) metals in coal and fly ash, (2) Pb in the Bandelier Tuff (BT), (3) Ba in tree rings, (4) Mn, Fe, Sr and Y in Yucca Mountain calcites. Micro-PIXE (MP) analyses with 5-10 micrometer spatial resolution provide constraints on processes that redistribute contaminants in the environment, and hence may help answer environmental problems where fine-scale chemical records are important. MP analyses of particulates in coal and ash show that pyrite contains As, Se, Hg and Pb; macerals contain Cr, halogens and S; cenospheres contain As, Se and Ni; and hematite ash contains Ni and As. Understanding these elemental modes of occurrence allows prediction of metal behavior in boilers and may enhance compliance with the Clean Air Act Amendments. Fine-grained high-Pb minerals were identified using SEM and MP analyses of BT minerals. These minerals were from samples associated with deep-groundwater wells containing Pb at levels greater than regulatory limits. Pb is concentrated in Pb minerals (e.g. cerussite), smectite, and hematite formed during low-T alteration of tuff. Understanding mineralogic speciation of metals may provide insights into sources of groundwater pollution. Tree rings from ponderosa pines that grew in a Ba-contaminated drainage were analyzed using MP. Ba concentrations are typically higher in rings that formed after operations discharging Ba to the environment began. Such tree-ring analyses may ultimately provide information on rates of contaminant migration in the environment. TE in zoned calcites from Yucca Mountain were analyzed by MP. Calcites from the saturated zone (SZ) have distinct chemical signatures (high Fe, Mn and low Y). No calcites in the unsaturated zone with SZ chemical signatures were found using MP

  18. Colloid process engineering

    Peukert, Wolfgang; Rehage, Heinz; Schuchmann, Heike

    2015-01-01

    This book deals with colloidal systems in technical processes and the influence of colloidal systems by technical processes. It explores how new measurement capabilities can offer the potential for a dynamic development of scientific and engineering, and examines the origin of colloidal systems and its use for new products. The future challenges to colloidal process engineering are the development of appropriate equipment and processes for the production and obtainment of multi-phase structures and energetic interactions in market-relevant quantities. The book explores the relevant processes and for controlled production and how they can be used across all scales.

  19. Parametric analysis of the growth of colloidal ZnO nanoparticles synthesized in alcoholic medium

    Fonseca, A. S.; Figueira, P. A.; Pereira, A. S.; Santos, R. J.; Trindade, T.; Nunes, M. I.

    2017-01-01

    The growth kinetics of nanosized ZnO was studied considering the influence of different parameters (mixing degree, temperature, alcohol chain length, reactant concentration and Zn/OH ratios) on the synthesis reaction and modelling the outputs using typical kinetic growth models, which were then evaluated by means of a sensitivity analysis. The Zn/OH ratio, the temperature and the alcohol chain length were found to be essential parameters to control the growth of ZnO nanoparticles, whereas zinc acetate concentration (for Zn/OH = 0.625) and the stirring during the ageing stage were shown to not have significant influence on the particle size growth. This last operational parameter was for the first time investigated for nanoparticles synthesized in 1-pentanol, and it is of outmost importance for the implementation of continuous industrial processes for mass production of nanosized ZnO and energy savings in the process. Concerning the nanoparticle growth modelling, the results show a different pattern from the more commonly accepted diffusion-limited Ostwald ripening process, i.e. the Lifshitz–Slyozov–Wagner (LSW) model. Indeed, this study shows that oriented attachment occurs during the early stages whereas for the later stages the particle growth is well represented by the LSW model. This conclusion contributes to clarify some controversy found in the literature regarding the kinetic model which better represents the ZnO NPs’ growth in alcoholic medium.

  20. Parametric analysis of the growth of colloidal ZnO nanoparticles synthesized in alcoholic medium

    Fonseca, A. S. [National Research Centre for the Working Environment (Denmark); Figueira, P. A.; Pereira, A. S. [Universidade de Aveiro, Departamento de Química—CICECO (Portugal); Santos, R. J. [Universidade do Porto, Laboratory of Separation and Reaction Engineering-Laboratory of Catalysis and Materials (LSRE-LCM), Faculdade de Engenharia (Portugal); Trindade, T. [Universidade de Aveiro, Departamento de Química—CICECO (Portugal); Nunes, M. I., E-mail: isanunes@ua.pt [Universidade de Aveiro, Centre for Environmental and Marine Studies (CESAM), Dep. de Ambiente e Ordenamento (Portugal)

    2017-02-15

    The growth kinetics of nanosized ZnO was studied considering the influence of different parameters (mixing degree, temperature, alcohol chain length, reactant concentration and Zn/OH ratios) on the synthesis reaction and modelling the outputs using typical kinetic growth models, which were then evaluated by means of a sensitivity analysis. The Zn/OH ratio, the temperature and the alcohol chain length were found to be essential parameters to control the growth of ZnO nanoparticles, whereas zinc acetate concentration (for Zn/OH = 0.625) and the stirring during the ageing stage were shown to not have significant influence on the particle size growth. This last operational parameter was for the first time investigated for nanoparticles synthesized in 1-pentanol, and it is of outmost importance for the implementation of continuous industrial processes for mass production of nanosized ZnO and energy savings in the process. Concerning the nanoparticle growth modelling, the results show a different pattern from the more commonly accepted diffusion-limited Ostwald ripening process, i.e. the Lifshitz–Slyozov–Wagner (LSW) model. Indeed, this study shows that oriented attachment occurs during the early stages whereas for the later stages the particle growth is well represented by the LSW model. This conclusion contributes to clarify some controversy found in the literature regarding the kinetic model which better represents the ZnO NPs’ growth in alcoholic medium.

  1. Emulsification in binary liquids containing colloidal particles: a structure-factor analysis

    Thijssen, Job H J; Clegg, Paul S

    2010-01-01

    We present a quantitative confocal-microscopy study of the transient and final microstructure of particle-stabilized emulsions formed via demixing in a binary liquid. To this end, we have developed an image-analysis method that relies on structure factors obtained from discrete Fourier transforms of individual frames in confocal image sequences. Radially averaging the squared modulus of these Fourier transforms before peak fitting allows extraction of dominant length scales over the entire temperature range of the quench. Our procedure even yields information just after droplet nucleation, when the (fluorescence) contrast between the two separating phases is scarcely discernible in the images. We find that our emulsions are stabilized on experimental timescales by interfacial particles and that they are likely to have bimodal droplet-size distributions. We attribute the latter to coalescence together with creaming being the main coarsening mechanism during the late stages of emulsification and we support this claim with (direct) confocal-microscopy observations. In addition, our results imply that the observed droplets emerge from particle-promoted nucleation, possibly followed by a free-growth regime. Finally, we argue that creaming strongly affects droplet growth during the early stages of emulsification. Future investigations could clarify the link between quench conditions and resulting microstructure, paving the way for tailor-made particle-stabilized emulsions from binary liquids.

  2. A photomultiplier-based secondary electron imaging system for a nuclear microprobe

    Alves, L.C.; Breese, M.B.H.; Silva, M.F. da; Soares, J.C.

    2002-01-01

    The ability to define, or recognise particular regions of interest or surface features is vital to the analysis and interpretation of spatially-resolved images collected with a nuclear microprobe. However, good topographic image contrast is difficult to accomplish using PIXE or RBS images due to their inherent insensitivity to topography, lack of elemental variation or poor statistics. Topographic image contrast is commonly obtained in scanning electron microscopy (SEM) by detecting a large flux of secondary electrons produced by the focused keV electron beam. Similar systems have not been widely used on nuclear microprobes due to ion beam intensity fluctuations, which limit the minimum resolvable contrast and present a major limitation for this technique. This paper describes a secondary electron imaging system which has been developed on the Lisbon microprobe. It is based on a scintillator, a photomultiplier operated in a pulsed mode, a pulse shaping electronic chain and ADC, and requires no changes to the existing data acquisition system. Examples of the images obtained from materials such as patterned SiGe wafers and hydrogen-implanted silicon are given, and compared with SEM or optical images

  3. Deep PIXE: finding diamonds with the proton microprobe

    Griffin, W.L.; Ryan, C.G.

    1991-01-01

    Since 1987 the CSIRO Div. of Exploration Geoscience has carried out a program of proton-microprobe (PIXE) analysis aimed at using trace-element data on indicator minerals to discriminate between those from diamondiferous and barren source rocks. The results have provided both important new tools for the exploration industry, and significant new information on the conditions and processes of diamond growth. Cr-pyrope garnet has been used as Ni thermometer while chromites, in partcular their Zn content, has allowed correlation of chromite composition with temperature. The two techniques described provide a significant increase in exploration efficiency, through early recognition and rejection of barren targets and concentration of resources on more promising targets. They also provide direct cost savings in evaluation of ore bodies once they are found. It is estimated that evaluation of a prospect by conventional bulk testing is expensive ($100-500K) and time-consuming; an evaluation by PIXE methods is done quickly for a tiny fraction of that cost. 1 refs., 4 figs

  4. Stability analysis of a model equilibrium for a gravito-electrostatic sheath in a colloidal plasma under external gravity effect

    Rajkhowa, Kavita Rani; Bujarbarua, S.; Dwivedi, C.B.

    1999-01-01

    The present contribution tries to find a scientific answer to the question of stability of an equilibrium plasma sheath in a colloidal plasma system under external gravity effect. A model equilibrium of hydrodynamical character has been discussed on the basis of quasi-hydrostatic approximation of levitational condition. It is found that such an equilibrium is highly unstable to a modified-ion acoustic wave with a conditional likelihood of linear driving of the so-called acoustic mode too. Thus, it is reported (within fluid treatment) that a plasma-sheath edge in a colloidal plasma under external gravity effect could be highly sensitive to the acoustic turbulence. Its consequential role on possible physical mechanism of Coulomb phase transition has been conjectured. However, more rigorous calculations as future course of work are required to corroborate our phenomenological suggestions. (author)

  5. Interface colloidal robotic manipulator

    Aronson, Igor; Snezhko, Oleksiy

    2015-08-04

    A magnetic colloidal system confined at the interface between two immiscible liquids and energized by an alternating magnetic field dynamically self-assembles into localized asters and arrays of asters. The colloidal system exhibits locomotion and shape change. By controlling a small external magnetic field applied parallel to the interface, structures can capture, transport, and position target particles.

  6. U/Th dating by SHRIMP RG ion-microprobe mass spectrometry using single ion-exchange beads

    Bischoff, J.L.; Wooden, J.; Murphy, F.; Williams, Ross W.

    2005-01-01

    We present a new analytical method for U-series isotopes using the SHRIMP RG (Sensitive High mass Resolution Ion MicroProbe) mass spectrometer that utilizes the preconcentration of the U-series isotopes from a sample onto a single ion-exchange bead. Ion-microprobe mass spectrometry is capable of producing Th ionization efficiencies in excess of 2%. Analytical precision is typically better than alpha spectroscopy, but not as good as thermal ionization mass spectroscopy (TIMS) and inductively coupled plasma multicollector mass spectrometry (ICP-MS). Like TIMS and ICP-MS the method allows analysis of small samples sizes, but also adds the advantage of rapidity of analysis. A major advantage of ion-microprobe analysis is that U and Th isotopes are analyzed in the same bead, simplifying the process of chemical separation. Analytical time on the instrument is ???60 min per sample, and a single instrument-loading can accommodate 15-20 samples to be analyzed in a 24-h day. An additional advantage is that the method allows multiple reanalyses of the same bead and that samples can be archived for reanalysis at a later time. Because the ion beam excavates a pit only a few ??m deep, the mount can later be repolished and reanalyzed numerous times. The method described of preconcentrating a low concentration sample onto a small conductive substrate to allow ion-microprobe mass spectrometry is potentially applicable to many other systems. Copyright ?? 2005 Elsevier Ltd.

  7. The remote control of nuclear microprobes over the Internet

    Churms, C.L.; Prozesky, V.M.; Springhorn, K.A.

    1999-01-01

    Whereas the concept of remote control is not new, the required equipment and data link have typically been costly and specialized. With the growing availability of reliable Internet connection, it has however become possible and increasingly attractive to be able to control complex equipment remotely over the Internet. Some methods of Internet Remote control are discussed, bearing in mind the specific needs of nuclear microprobe control. One such system has been implemented at the NAC nuclear microprobe, and even though improvements are envisaged, it is already functioning satisfactorily

  8. Extraterrestrial materials examined by mean of nuclear microprobe

    Khodja, H.; Smith, T.; Engrand, C.; Herzog, G.; Raepsaet, C.

    2013-07-01

    Comet fragments, micrometeorites, and Interplanetary Dust Particles (IDPs) are small objects (purpose, we need instruments and methods that provide both microanalysis and detailed imaging. In these respects, the nuclear microprobe offers many potential advantages: (i) the spatial resolution, ∼1 μm is well-matched to the typical object dimensions, (ii) with some reservations, it is non-destructive when carefully conducted, (iii) it is quantitative, and especially sensitive for light elements. At the Saclay nuclear microprobe, we have been performing analyses of extraterrestrial objects for many years. We review some of these studies, emphasizing the specific requirements for successful analyses. We also discuss the potential pitfalls that may be encountered.

  9. Formation and transport of radioactive colloids in porous media

    Chung, J.Y.; Lee, K.J.

    1993-01-01

    This paper deals with the effect of the presence of colloids in natural groundwater on radionuclide transport. The system considered here treats groundwater as a dispersing medium and colloid or finely divided solid material resulting from several different repository sources as a dispersed phase. Evaluation of the radionuclides adsorption on colloid, concepts of effective transport velocity and migration distance, and mathematical formulation of the filtration equation were driven, along with the case studies using typical parameter values of a conceptual radioactive waste repository and concentration on the effect of poly dispersed colloid on radionuclide transport. This paper also introduces the three phase analysis to treat the radionuclide transport more practically. When compared with the previously published experimental data, the modified filtration equation gives a satisfactory result. Results of the case studies show that the reduction of colloidal size enhances the corresponding colloid concentration when colloidal transport is only affected by diffusion phenomena. However, the three phase analysis shows that this trend can be reversed if the colloidal filtration becomes a dominant mechanism in the colloidal transport. Consequently, these results show that colloid could play a very important role in radionuclide transport under a repository environment

  10. Colloid chemistry: available sorption models and the question of colloid adhesion

    Grauer, R.

    1990-05-01

    A safety analysis of a radioactive waste repository should consider the possibility of nuclide transport by colloids. This would involve describing the sorption properties of the colloids and their transport in porous and fissured media. This report deals with a few selected aspects of the chemistry of this complex subject. Because the mechanisms of ion adsorption onto surfaces are material-specific, increased attention should be paid to identifying the material constitution of aquatic colloids. Suitable models already exist for describing reversible adsorption; these models describe sorption using mass action equations. The surface coordination model, developed for hydrous oxide surfaces, allows a uniform approach to be adopted for different classes of materials. This model is also predictive and has been applied successfully to natural systems. From the point of view of nuclide transport by colloids, irreversible sorption represents the most unfavourable situation. There is virtually no information available on the extent of reversibility and on the desorption kinetics of important nuclide/colloid combinations. Experimental investigations are therefore necessary in this respect. The only question considered in connection with colloid transport and its modelling is that of colloid sticking. Natural colloids, and the surfaces of the rock on which they may be collected, generally have negative surface charges so that colloid sticking will be difficult. The DLVO theory contains an approach for calculating the sticking factor from the surface potentials of the solid phases and the ionic strength of the water. However, it has been shown that this theory is inapplicable because of inherent shortcomings which lead to completely unrealistic predictions. The sticking probability of colloids should therefore be determined experimentally for systems which correspond as closely as possible to reality. (author) 66 figs., 12 tabs., 204 refs

  11. Explorative analysis of microbes, colloids and gases together with microbial modelling. Site description model SDM-Site Laxemar

    Hallbeck, Lotta; Pedersen, Karsten (Microbial Analytics Sweden AB, Goeteborg (Sweden))

    2008-08-15

    The work has involved the development of descriptive and mathematical models for groundwaters in relation to rock domains, fracture domains and deformation zones. Past climate changes are the major driving force for hydrogeochemical changes and therefore of fundamental importance for understanding the palaeohydrogeological, palaeohydrogeochemical and present evolution of groundwater in the crystalline bedrock of the Fennoscandian Shield. Understanding current undisturbed hydrochemical conditions at the proposed repository site is important when predicting future changes in groundwater chemistry. The causes of copper corrosion and/or bentonite degradation are of particular interest as they may jeopardise the long-term integrity of the planned SKB repository system. Thus, the following variables are considered for the hydrogeochemical site descriptive modelling: pH, Eh, sulphur species, iron, manganese, carbonate, phosphate, nitrogen species, total dissolved solids (TDS), isotopes, colloids, fulvic and humic acids and microorganisms. In addition, dissolved gases (e.g. carbon dioxide, methane and hydrogen) are of interest because of their likely participation in microbial reactions. In this series of reports, the final hydrogeochemical evaluation work of the site investigation at the Laxemar site, is presented. The work was conducted by SKB's hydrogeochemical project group, ChemNet, which consists of independent consultants and Univ. researchers with expertise in geochemistry, hydrochemistry, hydrogeochemistry, microbiology, geomicrobiology, analytical chemistry etc. The resulting site descriptive model version, mainly based on available primary data from the extended data freeze L2.3 (Nov 2007). This report focuses on microbiology, colloids and gases. Several methods must be used to characterise active microbial communities in groundwater. Microbial parameters of interest are the total number of cells (TNC) and the presence of various metabolic groups of

  12. Explorative analysis of microbes, colloids and gases together with microbial modelling. Site description model SDM-Site Laxemar

    Hallbeck, Lotta; Pedersen, Karsten

    2008-08-01

    The work has involved the development of descriptive and mathematical models for groundwaters in relation to rock domains, fracture domains and deformation zones. Past climate changes are the major driving force for hydrogeochemical changes and therefore of fundamental importance for understanding the palaeohydrogeological, palaeohydrogeochemical and present evolution of groundwater in the crystalline bedrock of the Fennoscandian Shield. Understanding current undisturbed hydrochemical conditions at the proposed repository site is important when predicting future changes in groundwater chemistry. The causes of copper corrosion and/or bentonite degradation are of particular interest as they may jeopardise the long-term integrity of the planned SKB repository system. Thus, the following variables are considered for the hydrogeochemical site descriptive modelling: pH, Eh, sulphur species, iron, manganese, carbonate, phosphate, nitrogen species, total dissolved solids (TDS), isotopes, colloids, fulvic and humic acids and microorganisms. In addition, dissolved gases (e.g. carbon dioxide, methane and hydrogen) are of interest because of their likely participation in microbial reactions. In this series of reports, the final hydrogeochemical evaluation work of the site investigation at the Laxemar site, is presented. The work was conducted by SKB's hydrogeochemical project group, ChemNet, which consists of independent consultants and Univ. researchers with expertise in geochemistry, hydrochemistry, hydrogeochemistry, microbiology, geomicrobiology, analytical chemistry etc. The resulting site descriptive model version, mainly based on available primary data from the extended data freeze L2.3 (Nov 2007). This report focuses on microbiology, colloids and gases. Several methods must be used to characterise active microbial communities in groundwater. Microbial parameters of interest are the total number of cells (TNC) and the presence of various metabolic groups of

  13. Clusters in attractive colloids

    Coniglio, A [Dipartimento di Scienze Fisiche, Universita di Napoli ' Federico II' , Complesso Universitario di Monte Sant' Angelo, via Cintia 80126 Naples (Italy); Arcangelis, L de [Dipartimento di Ingegneria dell' Informazione and CNISM II Universita di Napoli, Aversa (CE) (Italy); Candia, A de [Dipartimento di Scienze Fisiche, Universita di Napoli ' Federico II' , Complesso Universitario di Monte Sant' Angelo, via Cintia 80126 Naples (Italy); Gado, E Del [Dipartimento di Scienze Fisiche, Universita di Napoli ' Federico II' , Complesso Universitario di Monte Sant' Angelo, via Cintia 80126 Naples (Italy); Fierro, A [Dipartimento di Scienze Fisiche, Universita di Napoli ' Federico II' , Complesso Universitario di Monte Sant' Angelo, via Cintia 80126 Naples (Italy); Sator, N [Laboratoire de Physique Theorique de la Matiere Condensee, Universite Pierre et Marie Curie-Paris6, UMR (CNRS) 7600 Case 121, 4 Place Jussieu 75252 Paris Cedex 05 (France)

    2006-09-13

    We discuss how the anomalous increase of the viscosity in colloidal systems with short-range attraction can be related to the formation of long-living clusters. Based on molecular dynamics and Monte Carlo numerical simulations of different models, we propose a similar picture for colloidal gelation at low and intermediate volume fractions. On this basis, we analyze the distinct role played by the formation of long-living bonds and the crowding of the particles in the slow dynamics of attractive colloidal systems.

  14. Colloids in Biotechnology

    Fanun, Monzer

    2010-01-01

    Colloids have come a long way from when Thomas Graham coined the term colloid to describe 'pseudo solutions'. This book enables scientists to close the gap between extensive research and translation into commercial options in biomedicine and biotechnology. It covers biosurfactants and surface properties, phase behavior, and orientational change of surfactant mixtures with peptides at the interface. It also covers adsorption of polymers and biopolymers on the surface and interface, discusses colloidal nanoparticles and their use in biotechnology, and delves into bioadhesion and microencapsulati

  15. The effects of colloids or crystalloids on acute respiratory distress syndrome in swine (Sus scrofa models with severe sepsis: analysis on extravascular lung water, IL-8, and VCAM-1

    Rismala Dewi

    2016-04-01

    Full Text Available Background: Acute respiratory distress syndrome (ARDS is a fatal complication of severe sepsis. Due to its higher molecular weight, the use of colloids in fluid resuscitation may be associated with fewer cases of ARDS compared to crystalloids. Extravascular lung water (EVLW elevation and levels of interleukin-8 (IL-8 and vascular cell adhesion molecule-1 (VCAM-1 have been studied as indicators playing a role in the pathogenesis of ARDS. The aim of the study was to determine the effects of colloid or crystalloid on the incidence of ARDS, elevation of EVLW, and levels of IL-8 and VCAM-1, in swine models with severe sepsis.Methods: This was a randomized trial conducted at the Laboratory of Experimental Surgery, School of Veterinary Medicine, IPB, using 22 healthy swine models with a body weight of 8 to 12 kg. Subjects were randomly allocated to receive either colloid or crystalloid fluid resuscitation. After administration of endotoxin, clinical signs of ARDS, EVLW, IL-8, and VCAM-1 were monitored during sepsis, severe sepsis, and one- and three hours after fluid resuscitation. Analysis of data using the Wilcoxon test , Kolmogorov-Smirnov test, Mann-Whitney test, unpaired t test.Results: Mild ARDS was more prevalent in the colloid group, while moderate ARDS was more frequent in the crystalloid group. EVLW elevation was lower in the colloid compared to the crystalloid group. There was no significant difference in IL-8 and VCAM-1 levels between the two groups.Conclusion: The use of colloids in fluid resuscitation does not decrease the probability of ARDS events compared to crystalloids. Compared to crystalloids, colloids are associated with a lower increase in EVLWI, but not with IL-8 or VCAM-1 levels.

  16. Colloid Mobilization in Two Atlantic Coastal Plain Aquifers: Field Studies

    Ryan, Joseph N.; Gschwend, Philip M.

    1990-02-01

    The geochemical mechanisms leading to the mobilization of colloids in groundwater were investigated in the Pine Barrens of New Jersey and in rural central Delaware by sampling pairs of wells screened in oxic and anoxic groundwaters in the same geologic formations. Samples were carefully taken at very low flow rates (˜100 mL min-1) to avoid suspending immobilized particles. The colloidal matter was characterized by light-scattering photometry, scanning electron microscopy, energy-dispersive X ray analysis, microelectrophoresis, and Fe, Al, Si, and organic carbon analyses. The colloids, composed primarily of clays, were observed at high concentrations (up to 60 mg colloids/L) in the anoxic groundwaters, while the oxic groundwaters exhibited ≤1 mg colloids/L. Colloidal organic carbon was present in all groundwaters; but under anoxic conditions, one-third to one-half of the total organic carbon was associated with the inorganic colloids. The field evidence indicates that anoxic conditions cause the mobilization of soil colloids by dissolving the ferric oxyhydroxide coatings cementing the clay particles to the aquifer solids. The depletion of oxidized iron on the surfaces of immobile particles and the addition of organic carbon coatings on the soil particles and colloids apparently stabilizes the colloidal suspension in the anoxic groundwaters.

  17. Behavior of colloids in radionuclide migration in deep geologic formation

    Kanno, Takuji

    1994-01-01

    In case high level waste is isolated in deep strata, it is important to elucidate the behavior of movement that radionuclides take in the strata. Recently, it has been recognized that the participation of colloids is very important, and it has been studied actively. In this study, as to the mechanism of the adsorption of colloids to geological media or buffers, analysis was carried out for a number of systems, and it was clarified in what case they are caught or they move without being caught. Also it is considered what research is necessary hereafter. First, the kinds of colloids are shown. As the properties of colloids that control the movement of colloids in groundwater in deep strata, the surface potential, shape, size and so on of colloids are conceivable. These properties are briefly discussed. As the interaction of colloids and geological media, the interaction by electrostatic attraction, the fast and slow movement of colloids through rock crevices, and the filtration of colloids in buffers and porous media are described. The experimental results on the movement of colloids are reported. (K.I.)

  18. An SU-8-based microprobe with a nanostructured surface enhances neuronal cell attachment and growth

    Kim, Eunhee; Kim, Jin-Young; Choi, Hongsoo

    2017-12-01

    Microprobes are used to repair neuronal injury by recording electrical signals from neuronal cells around the surface of the device. Following implantation into the brain, the immune response results in formation of scar tissue around the microprobe. However, neurons must be in close proximity to the microprobe to enable signal recording. A common reason for failure of microprobes is impaired signal recording due to scar tissue, which is not related to the microprobe itself. Therefore, the device-cell interface must be improved to increase the number of neurons in contact with the surface. In this study, we developed nanostructured SU-8 microprobes to support neuronal growth. Nanostructures of 200 nm diameter and depth were applied to the surface of microprobes, and the attachment and neurite outgrowth of PC12 cells on the microprobes were evaluated. Neuronal attachment and neurite outgrowth on the nanostructured microprobes were significantly greater than those on non-nanostructured microprobes. The enhanced neuronal attachment and neurite outgrowth on the nanostructured microprobes occurred in the absence of an adhesive coating, such as poly- l-lysine, and so may be useful for implantable devices for long-term use. Therefore, nanostructured microprobes can be implanted without adhesive coating, which can cause problems in vivo over the long term.

  19. High resolution techniques using scanning proton microprobe (SPM)

    Cholewa, M.; Saint, A.; Prawer, S.; Laird, J.S.; Legge, G.J.F.; Bardos, R.A.; Moorhead, G.F.; Taylor, G.N.; Stuart, S.A.; Howard, J.

    1994-01-01

    The very high resolution (down to 50 nm) achieved with low beam currents (fA) in a scanning ion microprobe have lead to many nondestructive techniques of microanalysis. This paper discusses recent developments and applications in the use of 3-D STIM (scanning transmission ion microscopy) Tomography, channeling STIM and IBIC (ion beam induced charge). (orig.)

  20. The French AEC nuclear microprobe: description and first application examples

    Engelmann, C.; Bardy, J.

    1983-05-01

    The major components of the microprobe are briefly described. The performances and the varying possibilities authorized by the instrument are given. Some application examples concerning especially the determination of concentration profiles in an aqueous leached glass and the distribution of deuterium in a graphite sample exposed to plasma in a Tokamak device are presented

  1. Liquid crystal colloids

    Muševič, Igor

    2017-01-01

    This book brings together the many concepts and discoveries in liquid crystal colloids contributed over the last twenty years and scattered across numerous articles and book chapters. It provides both a historical overview of the development of the field and a clear perspective on the future applications in photonics. The book covers all phenomena observed in liquid crystal colloids with an emphasis on experimental tools and applications of topology in condensed matter, as well as practical micro-photonics applications. It includes a number of spectacular manifestations of new topological phenomena not found or difficult to observe in other systems. Starting from the early works on nematic colloids, it explains the basics of topological defects in ordered media, charge and winding, and the elastic forces between colloidal particles in nematics. Following a detailed description of experimental methods, such as optical tweezing and particle tracking, the book eases the reader into the theoretical part, which de...

  2. Liquid Crystal Colloids

    Smalyukh, Ivan I.

    2018-03-01

    Colloids are abundant in nature, science, and technology, with examples ranging from milk to quantum dots and the colloidal atom paradigm. Similarly, liquid crystal ordering is important in contexts ranging from biological membranes to laboratory models of cosmic strings and liquid crystal displays in consumer devices. Some of the most exciting recent developments in both of these soft matter fields emerge at their interface, in the fast-growing research arena of liquid crystal colloids. Mesoscale self-assembly in such systems may lead to artificial materials and to structures with emergent physical behavior arising from patterning of molecular order and nano- or microparticles into precisely controlled configurations. Liquid crystal colloids show exceptional promise for new discovery that may impinge on composite material fabrication, low-dimensional topology, photonics, and so on. Starting from physical underpinnings, I review the state of the art in this fast-growing field, with a focus on its scientific and technological potential.

  3. Filtration of polydispersed colloids

    Nuttall, H.E.

    1988-01-01

    In this study, the dynamic microscopic form of the population balance model is applied to the problem of polydispersed particle capture in one spatial diffusion. This mathematical modeling approach can be applied to the difficult and potentially important problem of particulate (radiocolloid) transport in the groundwater surrounding a nuclear waste disposal site. To demonstrate the population balance methodology, the equations were developed and used to investigate transport and capture of polydispersed colloids in packed columns. Modeling simulations were compared to experimental column data. The multidimensional form of the population balance equation was used to analyze the transport and capture of polydispersed colloids. A numerical model was developed to describe transport of polydispersed colloids through a one-dimensional porous region. The effects of various size distributions were investigated in terms of capture efficiency. For simulating the column data, it was found by trial and error that as part of the population balance model a linear size dependent filtration function gave a good fit to the measured colloid concentration profile. The effects of constant versus size dependent filtration coefficients were compared and the differences illustrated by the calculated colloid profile within the column. Also observed from the model calculations was the dramatically changing liquid-phase colloid-size distribution which was plotted as a function of position down the column. This modeling approach was excellent for describing and understanding microscopic filtration in porous media

  4. Fabrication and surface-modification of implantable microprobes for neuroscience studies

    Cao, H; Nguyen, C M; Chiao, J C

    2012-01-01

    In this work implantable micro-probes for central nervous system (CNS) studies were developed on silicon and polyimide substrates. The probes which contained micro-electrode arrays with different surface modifications were designed for implantation in the CNS. The electrode surfaces were modified with nano-scale structures that could greatly increase the active surface area in order to enhance the electrochemical current outputs while maintaining micro-scale dimensions of the electrodes and probes. The electrodes were made of gold or platinum, and designed with different sizes. The silicon probes were modified by silicon nanowires fabricated with the vapor–liquid–solid mechanism at high temperatures. With polyimide substrates, the nanostructure modification was carried out by applying concentrated gold or silver colloid solutions onto the micro-electrodes at room temperature. The surfaces of electrodes before and after modification were observed by scanning electron microscopy. The silicon nanowire-modified surface was characterized by cyclic voltammetry. Experiments were carried out to investigate the improvement in sensing performance. The modified electrodes were tested with H 2 O 2 , electrochemical L-glutamate and dopamine. Comparisons between electrodes with and without nanostructure modification were conducted showing that the modifications have enhanced the signal outputs of the electrochemical neurotransmitter sensors

  5. Fabrication and surface-modification of implantable microprobes for neuroscience studies

    Cao, H.; Nguyen, C. M.; Chiao, J. C.

    2012-06-01

    In this work implantable micro-probes for central nervous system (CNS) studies were developed on silicon and polyimide substrates. The probes which contained micro-electrode arrays with different surface modifications were designed for implantation in the CNS. The electrode surfaces were modified with nano-scale structures that could greatly increase the active surface area in order to enhance the electrochemical current outputs while maintaining micro-scale dimensions of the electrodes and probes. The electrodes were made of gold or platinum, and designed with different sizes. The silicon probes were modified by silicon nanowires fabricated with the vapor-liquid-solid mechanism at high temperatures. With polyimide substrates, the nanostructure modification was carried out by applying concentrated gold or silver colloid solutions onto the micro-electrodes at room temperature. The surfaces of electrodes before and after modification were observed by scanning electron microscopy. The silicon nanowire-modified surface was characterized by cyclic voltammetry. Experiments were carried out to investigate the improvement in sensing performance. The modified electrodes were tested with H2O2, electrochemical L-glutamate and dopamine. Comparisons between electrodes with and without nanostructure modification were conducted showing that the modifications have enhanced the signal outputs of the electrochemical neurotransmitter sensors.

  6. Saturated Zone Colloid-Facilitated Transport

    Wolfsberg, A.; Reimus, P.

    2001-01-01

    The purpose of the Saturated Zone Colloid-Facilitated Transport Analysis and Modeling Report (AMR), as outlined in its Work Direction and Planning Document (CRWMS MandO 1999a), is to provide retardation factors for colloids with irreversibly-attached radionuclides, such as plutonium, in the saturated zone (SZ) between their point of entrance from the unsaturated zone (UZ) and downgradient compliance points. Although it is not exclusive to any particular radionuclide release scenario, this AMR especially addresses those scenarios pertaining to evidence from waste degradation experiments, which indicate that plutonium and perhaps other radionuclides may be irreversibly attached to colloids. This report establishes the requirements and elements of the design of a methodology for calculating colloid transport in the saturated zone at Yucca Mountain. In previous Total Systems Performance Assessment (TSPA) analyses, radionuclide-bearing colloids were assumed to be unretarded in their migration. Field experiments in fractured tuff at Yucca Mountain and in porous media at other sites indicate that colloids may, in fact, experience retardation relative to the mean pore-water velocity, suggesting that contaminants associated with colloids should also experience some retardation. Therefore, this analysis incorporates field data where available and a theoretical framework when site-specific data are not available for estimating plausible ranges of retardation factors in both saturated fractured tuff and saturated alluvium. The distribution of retardation factors for tuff and alluvium are developed in a form consistent with the Performance Assessment (PA) analysis framework for simulating radionuclide transport in the saturated zone. To improve on the work performed so far for the saturated-zone flow and transport modeling, concerted effort has been made in quantifying colloid retardation factors in both fractured tuff and alluvium. The fractured tuff analysis used recent data

  7. New 2-stage ion microprobes and a move to higher energies

    Legge, G.J.F.; Dymnikov, A.; Moloney, G.; Saint, A. [Melbourne Univ., Parkville, VIC (Australia). School of Physics; Cohen, D. [Australian Nuclear Science and Technology Organisation, Lucas Heights, NSW (Australia)

    1996-12-31

    Recent moves in Ion Beam Microanalysis towards the use of a rapidly growing number of very high resolution, low current and single ion techniques has led to the need for high demagnification and greatly improved beam quality. There is also a move to apply Microbeams at higher energies and with heavier ions. This also puts demands on the focusing system and beam control. This paper describes the recent development of 2-stage lens systems to be applied here and overseas, both at very high resolution and at high energies with heavy ions. It looks at new ion beam analysis applications of such ion microprobes. 8 refs., 1 tab., 1 fig.

  8. A new Krakow scanning nuclear microprobe performance tests and early application experienc

    Lebed, S; Polak, W; Potempa, A W; Stachura, Z; Paszkowski, M

    2001-01-01

    A new scanning nuclear microprobe (MP) with a short-length probe forming system was designed,installed and tested at the 3MV Van de Graaff accelerator in Krakow.The MP resolution of 3.3 mu m was reached for 2.4 MeV proton beam in the high-current mode (>= 100pA).The MP facility provides a local,non-destructive,quantitative elemental microanalysis using a Proton Induced X-ray Emission (PIXE) technique.As example of possible application an analysis of a geological sample containing monazite crystals investigated by PIXE method is presented.

  9. New 2-stage ion microprobes and a move to higher energies

    Legge, G J.F.; Dymnikov, A; Moloney, G; Saint, A [Melbourne Univ., Parkville, VIC (Australia). School of Physics; Cohen, D [Australian Nuclear Science and Technology Organisation, Lucas Heights, NSW (Australia)

    1997-12-31

    Recent moves in Ion Beam Microanalysis towards the use of a rapidly growing number of very high resolution, low current and single ion techniques has led to the need for high demagnification and greatly improved beam quality. There is also a move to apply Microbeams at higher energies and with heavier ions. This also puts demands on the focusing system and beam control. This paper describes the recent development of 2-stage lens systems to be applied here and overseas, both at very high resolution and at high energies with heavy ions. It looks at new ion beam analysis applications of such ion microprobes. 8 refs., 1 tab., 1 fig.

  10. CMB v. 1.1 Data Acquisition and Evaluation System of the Cracow Nuclear Microprobe

    Lekki, J.; Hajduk, R.; Potempa, A.; Pieprzyca, T.; Stachura, Z.; Zieblinski, M.; Styczen, J.; Lebed, S.

    2000-11-01

    An overview of the Cracow nuclear microprobe together with its data acquisition and control system is presented. Magnetic deflection was applied for beam scanning, while detector signals acquisition is performed by the NIM/CAMAC modules under supervision of a Windows operating system running on a PC equipped with the GPIB controller card. Total spectra from every detector are accessible on-line during the measurement, while full information about detected energy and beam position is stored to a disk file in the list mode to allow off-line data analysis. System hardware and software setups together with software operations and data formats used for information storing are described. (author)

  11. X-ray microprobe measurements of the chemical compositions of ALH84001 carbonate globules

    Flynn, G.J.; Sutton, S.R.; Keller, L.P.

    2004-01-01

    We measured minor element contents of carbonate from ALH84001 and report trends in tbe Ca, V, Mn and Sr in carbonate and the associated magnetite bands. McKay et al. suggested that carbonate globules in the ALH84001 meteorite from Mars contained evidence consistent with the development of bacterial life early in the history of Mars. This result provoked an extensive study of the ALH84001 meteorite. More recently Thomas-Keprta et al. have published a study showing that the magnetite associated with carbonate rims are of the size and shape produced by terrestrial bacteria. This paper has revived interest in ALH84001. The typical ALH84001 carbonate globule consists of four regions: a core of Fe-rich carbonate, a thin magnetite-rich band, a rim of Mn-rich carbonate, and another thin magnetite-rich band. Trace element analysis of each of these phases may allow us to address several important questions about these carbonates: (1) The origin of the magnetite-rich bands in the ALH84001 carbonate globules. If the magnetites are derived from the underlying carbonate through thermal decomposition (as proposed by Golden et al.), then we expect to see 'inherited' trace elements in these magnetite bands. (2) The origin of the rim carbonate, by determining whether the carbonate in the core has the same trace elements as the rim carbonates. (3) The age of the rim carbonate. Borg et al. dated the formation of the rim carbonate using the Rb/Sr chronometer. Borg et al. performed their measurements on an aliquot of what they called a high-Rb, low-Sr carbonate separate from the rim. We previously measured the trace element contents of chips from core and rim carbonates from an ALH84001 carbonate globule using an X-Ray Microprobe on Beamline X26A at the National Synchrotron Light Source. These measurements showed the rim carbonate had a very low Rb content, with Sr>>Rb, inconsistent with the ∼5 ppm Rb reported by Borg et al. in the sample they dated by the Rb/Sr chronometer. The large

  12. Individual precipitates in Al alloys probed by the Bonn positron microprobe

    Balarisi, Osman; Eich, Patrick; Haaks, Matz; Klobes, Benedikt; Korff, Bjoern; Maier, Karl; Sottong, Reinhard [Helmholtz-Institut fuer Strahlen- und Kernphysik, Nussallee 14-16, 53115 Bonn (Germany); Huehne, Sven-Martin; Mader, Werner [Institut fuer Anorganische Chemie, Roemerstrasse 164, 53117 Bonn (Germany); Staab, Torsten [Fraunhofer ISC, Neunerplatz 2, 97082 Wuerzburg (Germany)

    2010-07-01

    Positron annihilation spectroscopy (PAS) is a unique tool for the characterization of open-volume defects such as vacancies. Therefore, age hardenable Al alloys, whose decomposition is mainly driven by the vacancy mechanism of diffusion, are often characterized by PAS techniques. Nevertheless, probing the defect state of individual precipitates grown in Al alloys requires a focused positron beam and has not been carried out up to now. In this respect we present the first investigations of the defect state of individual precipitates utilizing the Bonn Positron Microprobe (BPM). Furthermore, the analysis of the experimental data has to be facilitated by theoretical calculations of the observables of positron annihilation spectroscopy.

  13. Effect of magnetic quadrupole lens alignment on a nuclear microprobe resolution

    Kolinko, S.V.; Ponomarev, A.G.

    2016-01-01

    The paper reports the research trends in developing probe-forming systems with high demagnification and analysis factors that limit a nuclear microprobe resolution. Parasitic aberrations caused by tilts and offsets of magnetic quadrupoles are studied in terms of their effect on probe parameters on a target. The most common arrangements of probe-forming systems such as a triplet and “Russian quadruplet” with separated geometry are considered. The accuracy prerequisites for the positioning of the quadrupoles are defined, and practical guidelines for alignment of probe-forming systems with high demagnification factors are suggested.

  14. Colloid migration in groundwaters: Geochemical interactions of radionuclides with natural colloids. Final report

    Kim, J.J.; Longworth, G.; Hasler, S.E.; Gardiner, M.; Fritz, P.; Klotz, D.; Lazik, D.; Wolf, M.; Geyer, S.; Alexander, J.L.; Read, D.; Thomas, J.B.

    1994-08-01

    In this joint research programme the significance of groundwater colloids in far field radionuclide migration has been studied. The characterization, quantification and theoretical interpretation of colloid-borne transport phenomena for radionuclides were the main objectives of this research programme. Groundwaters, colloids and sediments were sampled from aquifer system overlying a saltdome in the Gorleben area in northern Germany and were characterized by various analytical methods (ICP-MS, ICP-AES, neutron activation analysis (NAA), DOC-Analyser, HPIC, potentiometric titration). Different natural isotopes ( 2 H, 3 H, 13 C, 14 C, 18 O, 34 S, U/Th decay series) were determined and their ratios were compared with one another in the order to ascertain the provenance of the groundwater colloids. The investigated groundwaters contain substantial amounts of colloids mainly composed of humic and fulvic acids loaded with various metal ions. The chemical interaction of radionuclide ions of various oxidation states (Am, Eu, for M(III), Th, Pu for M(IV), Np for M(V) and U for M(VI)) with groundwater colloids was investigated in order to elucidate the colloid facilitated migration behaviour of actinides in a given aquifer system. Transport process studies with generated pseudocolloids of radionuclides in various oxidation states were undertaken in scaled column experiments, pre-equilibrated with colloid rich Gorleben groundwater. A modelling programme was developed to predict chemical transport of radionuclides in the presence of humic colloids using a modified version of the CHEMTARD code. Modelling predictions have generated acceptable results for Eu, Am and U and poorer agreement between experimental and modelling results for Th and Np as a result of more limited data. (orig.)

  15. Colloid migration in groundwaters: Geochemical interactions of radionuclides with natural colloids. Final report

    Kim, J.J. [Technische Univ. Muenchen, Garching (Germany). Inst. fuer Radiochemie; Delakowitz, B. [Technische Univ. Muenchen, Garching (Germany). Inst. fuer Radiochemie; Zeh, P. [Technische Univ. Muenchen, Garching (Germany). Inst. fuer Radiochemie; Probst, T. [Technische Univ. Muenchen, Garching (Germany). Inst. fuer Radiochemie; Lin, X. [Technische Univ. Muenchen, Garching (Germany). Inst. fuer Radiochemie; Ehrlicher, U. [Technische Univ. Muenchen, Garching (Germany). Inst. fuer Radiochemie; Schauer, C. [Technische Univ. Muenchen, Garching (Germany). Inst. fuer Radiochemie; Ivanovich, M. [AEA Environment and Energy, Harwell (United Kingdom); Longworth, G. [AEA Environment and Energy, Harwell (United Kingdom); Hasler, S.E. [AEA Environment and Energy, Harwell (United Kingdom); Gardiner, M. [AEA Decommissioning and Radwaste, Harwell (United Kingdom); Fritz, P. [Gesellschaft fuer Strahlen- und Umweltforschung mbH Muenchen, Neuherberg (Germany); Klotz, D. [Gesellschaft fuer Strahlen- und Umweltforschung mbH Muenchen, Neuherberg (Germany); Lazik, D. [Gesellschaft fuer Strahlen- und Umweltforschung mbH Muenchen, Neuherberg (Germany); Wolf, M. [Gesellschaft fuer Strahlen- und Umweltforschung mbH Muenchen, Neuherberg (Germany); Geyer, S. [Gesellschaft fuer Strahlen- und Umweltforschung mbH Muenchen, Neuherberg (Germany); Alexander, J.L. [Atkins (W.S.) Engineering Sciences, Epsom (United Kingdom); Read, D. [Atkins (W.S.) Engineering Sciences, Epsom (United Kingdom); Thomas, J.B. [Atkins (W.S.) Engineering Sciences, Epsom (United Kingdom)

    1994-08-01

    In this joint research programme the significance of groundwater colloids in far field radionuclide migration has been studied. The characterization, quantification and theoretical interpretation of colloid-borne transport phenomena for radionuclides were the main objectives of this research programme. Groundwaters, colloids and sediments were sampled from aquifer system overlying a saltdome in the Gorleben area in northern Germany and were characterized by various analytical methods (ICP-MS, ICP-AES, neutron activation analysis (NAA), DOC-Analyser, HPIC, potentiometric titration). Different natural isotopes ({sup 2}H, {sup 3}H, {sup 13}C, {sup 14}C, {sup 18}O, {sup 34}S, U/Th decay series) were determined and their ratios were compared with one another in the order to ascertain the provenance of the groundwater colloids. The investigated groundwaters contain substantial amounts of colloids mainly composed of humic and fulvic acids loaded with various metal ions. The chemical interaction of radionuclide ions of various oxidation states (Am, Eu, for M(III), Th, Pu for M(IV), Np for M(V) and U for M(VI)) with groundwater colloids was investigated in order to elucidate the colloid facilitated migration behaviour of actinides in a given aquifer system. Transport process studies with generated pseudocolloids of radionuclides in various oxidation states were undertaken in scaled column experiments, pre-equilibrated with colloid rich Gorleben groundwater. A modelling programme was developed to predict chemical transport of radionuclides in the presence of humic colloids using a modified version of the CHEMTARD code. Modelling predictions have generated acceptable results for Eu, Am and U and poorer agreement between experimental and modelling results for Th and Np as a result of more limited data. (orig.)

  16. ;Study of secondary hydriding at high temperature in zirconium based nuclear fuel cladding tubes by coupling information from neutron radiography/tomography, electron probe micro analysis, micro elastic recoil detection analysis and laser induced breakdown spectroscopy microprobe

    Brachet, Jean-Christophe; Hamon, Didier; Le Saux, Matthieu; Vandenberghe, Valérie; Toffolon-Masclet, Caroline; Rouesne, Elodie; Urvoy, Stéphane; Béchade, Jean-Luc; Raepsaet, Caroline; Lacour, Jean-Luc; Bayon, Guy; Ott, Frédéric

    2017-05-01

    This paper gives an overview of a multi-scale experimental study of the secondary hydriding phenomena that can occur in nuclear fuel cladding materials exposed to steam at high temperature (HT) after having burst (loss-of-coolant accident conditions). By coupling information from several facilities, including neutron radiography/tomography, electron probe micro analysis, micro elastic recoil detection analysis and micro laser induced breakdown spectroscopy, it was possible to map quantitatively, at different scales, the distribution of oxygen and hydrogen within M5™ clad segments having experienced ballooning and burst at HT followed by steam oxidation at 1100 and 1200 °C and final direct water quenching down to room temperature. The results were very reproducible and it was confirmed that internal oxidation and secondary hydriding at HT of a cladding after burst can lead to strong axial and azimuthal gradients of hydrogen and oxygen concentrations, reaching 3000-4000 wt ppm and 1.0-1.2 wt% respectively within the β phase layer for the investigated conditions. Consistent with thermodynamic and kinetics considerations, oxygen diffusion into the prior-β layer was enhanced in the regions highly enriched in hydrogen, where the α(O) phase layer is thinner and the prior-β layer thicker. Finally the induced post-quenching hardening of the prior-β layer was mainly related to the local oxygen enrichment. Hardening directly induced by hydrogen was much less significant.

  17. Actinide colloid generation in groundwater

    Kim, J.I.

    1990-05-01

    The progress made in the investigation of actinide colloid generation in groundwaters is summarized and discussed with particular examples relevant to an understanding of the migration behaviour of actinides in natural aquifer systems. The first part deals with the characterization of colloids: groundwater colloids, actinide real-colloids and actinide pseudocolloids. The second part concentrates on the generation processes and migration behaviour of actinide pseudocolloids, which are discussed with some notable experimental examples. Importance is stressed more on the chemical aspects of the actinide colloid generation in groundwater. This work is a contribution to the CEC project MIRAGE II, particularly, to research area: complexation and colloids. (orig.)

  18. “Study of secondary hydriding at high temperature in zirconium based nuclear fuel cladding tubes by coupling information from neutron radiography/tomography, electron probe micro analysis, micro elastic recoil detection analysis and laser induced breakdown spectroscopy microprobe

    Brachet, Jean-Christophe, E-mail: jean-christophe.brachet@cea.fr [DEN-Service de Recherches Métallurgiques Appliquées (SRMA), CEA, Université Paris-Saclay, 91191 Gif-sur-Yvette (France); Hamon, Didier; Le Saux, Matthieu [DEN-Service de Recherches Métallurgiques Appliquées (SRMA), CEA, Université Paris-Saclay, 91191 Gif-sur-Yvette (France); Vandenberghe, Valérie [DEN-Service de Recherches Métallurgiques Appliquées (SRMA), CEA, Université Paris-Saclay, 91191 Gif-sur-Yvette (France); DEN-Service d’Etudes Mécaniques et Thermiques (SEMT), CEA, Université Paris-Saclay, 91191 Gif-sur-Yvette (France); Toffolon-Masclet, Caroline; Rouesne, Elodie; Urvoy, Stéphane [DEN-Service de Recherches Métallurgiques Appliquées (SRMA), CEA, Université Paris-Saclay, 91191 Gif-sur-Yvette (France); Béchade, Jean-Luc [DEN-Service de Recherches Métallurgiques Appliquées (SRMA), CEA, Université Paris-Saclay, 91191 Gif-sur-Yvette (France); DEN-Service de Recherches de Métallurgie Physique (SRMP), CEA, Université Paris-Saclay, 91191 Gif-sur-Yvette (France); Raepsaet, Caroline [LEEL, CEA, Université Paris-Saclay, 91191 Gif-sur-Yvette (France); NIMBE, CEA, CNRS, Université Paris-Saclay, 91191 Gif-sur-Yvette Cedex (France); and others

    2017-05-15

    This paper gives an overview of a multi-scale experimental study of the secondary hydriding phenomena that can occur in nuclear fuel cladding materials exposed to steam at high temperature (HT) after having burst (loss-of-coolant accident conditions). By coupling information from several facilities, including neutron radiography/tomography, electron probe micro analysis, micro elastic recoil detection analysis and micro laser induced breakdown spectroscopy, it was possible to map quantitatively, at different scales, the distribution of oxygen and hydrogen within M5™ clad segments having experienced ballooning and burst at HT followed by steam oxidation at 1100 and 1200 °C and final direct water quenching down to room temperature. The results were very reproducible and it was confirmed that internal oxidation and secondary hydriding at HT of a cladding after burst can lead to strong axial and azimuthal gradients of hydrogen and oxygen concentrations, reaching 3000–4000 wt ppm and 1.0–1.2 wt% respectively within the β phase layer for the investigated conditions. Consistent with thermodynamic and kinetics considerations, oxygen diffusion into the prior-β layer was enhanced in the regions highly enriched in hydrogen, where the α(O) phase layer is thinner and the prior-β layer thicker. Finally the induced post-quenching hardening of the prior-β layer was mainly related to the local oxygen enrichment. Hardening directly induced by hydrogen was much less significant. - Highlights: •More than 50% of the gaseous hydrogen produced by the inner clad oxidation absorbed and trapped into prior-β layer. •High hydrogen and oxygen local concentrations, up to 3000–4000 wt. ppm and 1.0–1.2 wt.% respectively, within the β phase. •Enhanced oxygen diffusion into hydrogen enriched prior-β layer, with locally thinner α(O) and thicker prior-β layers. •Post-quenching hardening of the prior-β structure mainly related to the (local) oxygen concentration.

  19. Development of a scanning proton microprobe - computer-control, elemental mapping and applications

    Loevestam, Goeran.

    1989-08-01

    A scanning proton microprobe set-up has been developed at the Pelletron accelerator in Lund. A magnetic beam scanning system and a computer-control system for beam scanning and data aquisition is described. The computer system consists of a VMEbus front-end computer and a μVax-II host-computer, interfaced by means of a high-speed data link. The VMEbus computer controls data acquisition, beam charge monitoring and beam scanning while the more sophisticated work of elemental mapping and spectrum evaluations is left to the μVax-II. The calibration of the set-up is described as well as several applications. Elemental micro patterns in tree rings and bark has been investigated by means of elemental mapping and quantitative analysis. Large variations of elemental concentrations have been found for several elements within a single tree ring. An external beam set-up has been developed in addition to the proton microprobe set-up. The external beam has been used for the analysis of antique papyrus documents. Using a scanning sample procedure and particle induced X-ray emission (PIXE) analysis, damaged and missing characters of the text could be made visible by means of multivariate statistical data evaluation and elemental mapping. Also aspects of elemental mapping by means of scanning μPIXE analysis are discussed. Spectrum background, target thickness variations and pile-up are shown to influence the structure of elemental maps considerably. In addition, a semi-quantification procedure has been developed. (author)

  20. Characterization of semiconductor and frontier materials by nuclear microprobe technology

    Zhu Jieqing; Li Xiaolin; Yang Changyi; Lu Rongrong; Wang Jiqing; Guo Panlin

    2002-01-01

    The nuclear microprobe technology is used to characterize the properties of semiconductor and other frontier materials at the stages of their synthesis, modification, integration and application. On the basis of the beam current being used, the analytical nuclear microprobe techniques being used in this project can be divided into two categories: high beam current (PIXE, RBS, PEB) or low beam current (IBIC, STIM) techniques. The material properties measured are the thickness and composition of a composite surface on a SiC ceramic, the sputtering-induced surface segregation and depth profile change in a Ag-Cu binary alloy, the irradiation effects on the CCE of CVD diamond, the CCE profile at a polycrystalline CVD diamond film and a GaAs diode at different voltage biases and finally, the characterization of individual sample on an integrated material chip. (author)

  1. Installation and performance of the Budapest-Hamburg proton microprobe

    Kovacs, I.; Kocsonya, A.; Kostka, P.; Szokefalvi-Nagy, Z.; Schrang, K.; Krueger, A.; Niecke, M.

    2005-01-01

    A new scanning proton microprobe has been installed at the 5 MV Van de Graaff accelerator of the KFKI Research Institute for Particle and Nuclear Physics. It is the energy-upgraded version of the Hamburg proton microprobe dismantled in 2001. The probe forming system includes a pair of focusing quadrupoles and an additional quadrupole pair in front of it, which is applied to increase the proton beam divergence. The average probe size at 2.5 MeV proton energy is 2.2 μm x 1.1 μm. The test results on stability and the preliminary experiments on cement corrosion and fish otoliths are also presented

  2. Wavelength dispersive μPIXE setup for the ion microprobe

    Fazinić, S., E-mail: stjepko.fazinic@irb.hr [Laboratory for Ion Beam Interactions, Division of Experimental Physics, Rudjer Bošković Institute, Bijenicka cesta 54, 10000 Zagreb (Croatia); Božičević Mihalić, I.; Tadić, T.; Cosic, D.; Jakšić, M. [Laboratory for Ion Beam Interactions, Division of Experimental Physics, Rudjer Bošković Institute, Bijenicka cesta 54, 10000 Zagreb (Croatia); Mudronja, D. [Croatian Conservation Institute, Grškovićeva 23, 10000 Zagreb (Croatia)

    2015-11-15

    We have developed a small wavelength dispersive X-ray spectrometer to explore the possibility of performing chemical speciation on microscopic samples utilizing focused ion beams available at the Rudjer Boskovic Institute ion microprobe. Although PIXE spectra are in principle chemically invariant, small influence of chemical effects could be observed even with Si(Li) or SDD detectors. Such chemical effects can be clearly seen with high resolution crystal X-ray spectrometers having energy resolution of several eV. A dedicated vacuum chamber, housing the diffraction crystal, sample holder and CCD X-ray detector, was constructed and positioned behind the main ion microprobe vacuum chamber. Here we will briefly describe the spectrometer, and illustrate its capabilities on measured K X-ray spectra of selected sulfur compounds. We will also demonstrate its abilities to resolve K and M X-ray lines irresolvable by solid state ED detectors usually used in PIXE.

  3. Raman microprobe study of heat-treated pitches

    Cottinet, D.; Couderc, P.; Saint Romain, J.L.; Dhamelincourt, P.

    1988-01-01

    A series of heat-treated pitches from the same coal-tar precursor is investigated by means of a Raman microprobe. Separated Raman spectra are obtained for the isotropic phase and the mesophase. The evolutions observed are characteristic of the structural rearrangement change in the two phases. They correlate well with the observations reported in literature and obtained by using different methods of structural investigations.

  4. Design considerations for an x-ray microprobe

    Howells, M.R.; Hastings, J.B.

    1982-01-01

    The optical design of a fluorescent microprobe covering the x-ray region from 2 to 16 keV is considered for the NSLS x-ray ring. The limit on detectability is from total flux (photons/μm 2 ) and several design choices are considered to match the optical system to the storage ring to maximize throughput. The tradeoffs in image quality and energy resolution of these designs have been considered and within these constraints two firm proposals are presented

  5. The nuclear microprobe of the CENBG: the choices

    Llabador, Y.

    1987-04-01

    A microbeam line with a spatial resolution of the micrometer order has been set on the Van de Graaf of the Bordeaux-Gradignan nuclear center. This report presents the different stages of the microprobe design: the experimental device which has been chosen, the reason of the different choices, the traps to keep out of during the construction (for instance, the accuracy of the mechanical standards) [fr

  6. Use of X-ray microprobe to diagnose bone tissue demineralization after caffeine administration Use of X-ray microprobe to diagnose bone tissue demineralization after caffeine administration

    Marek Tomaszewski

    2012-10-01

    Full Text Available Caffeine is a methylxanthine which permeates the placenta. In studies on animals, it has been
    shown to produce teratogenic and embryotoxic effects in large doses. The objective of this study was to
    assess the influence of caffeine on the development of bone tissue, with particular reference to elemental
    bone composition using an X-ray microprobe. The research was conducted on rats. The fertilized females
    were randomly divided into an experimental and a control group. The experimental group was
    given caffeine orally in 30 mg/day doses from the 8th to the 21st day of pregnancy, while the control group
    was given water. The fetuses were used to assess the growth and mineralization of the skeleton. On the
    basis of double dyeing, a qualitative analysis of the bone morphology and mineralization was conducted.
    For calcium and potassium analysis, an X-ray microprobe was used. In 67 fetuses from the experimental
    group, changes in skeleton staining with the alcian-alizarin method were noticed. The frequency of the
    development of variants in the experimental group was statistically higher. In the experimental group,
    a significant decrease in the calcium level, as well as an increase in the potassium level, was observed.
    The X-ray microprobe’s undoubted advantage is that is offers a quick qualitative and quantitative analysis
    of the elemental composition of the examined samples. Employing this new technique may furnish us
    with new capabilities when investigating the essence of the pathology process.Caffeine is a methylxanthine which permeates the placenta. In studies on animals, it has been
    shown to produce teratogenic and embryotoxic effects in large doses. The objective of this study was to
    assess the influence of caffeine on the development of bone tissue, with particular reference to elemental
    bone composition using an X-ray microprobe. The research was conducted on

  7. The Fudan nuclear microprobe set-up and performance

    Zhong, L.; Zhuang, W.; Shen, H.; Mi, Y.; Wu, Y.; Liu, B.; Yang, M.; Cheng, H.

    2007-01-01

    A new scanning nuclear microprobe has been constructed at the Institute of Modern Physics in Fudan University, to replace the old microbeam system which had been running for more than ten years. The key parts were purchased from Oxford Microbeams Ltd., including triplet quadrupole lens (model OM-150), collimator slits, scanning system, target chamber, and data acquisition system. Ion beams are provided from a NEC 9SDH-2 Tandem accelerator. Three CCD cameras and multiple monitors were installed to assist beam adjust. The design of beam line and beam monitors is described. Beam optics calculations were carried out based on the specific Fudan microprobe system geometry, and the results regarding beam line performance and limitations of the spacial resolution are presented and discussed here. A comparison with experimental results is given as well. About 1.5 μm beam spot size could be achieved with a 3 MeV proton beam at a current of around 10 pA. Recently, the new microprobe is applied to obtain information of fly ash particle, algae cell and otoliths

  8. Nuclear microprobe studies of elemental distribution in the seagrass Thalassodendron ciliatum

    Barnabas, A.D. E-mail: alban@pixie.udw.ac.za; Przybylowicz, W.J.; Mesjasz-Przybylowicz, J.; Pineda, C.A

    1999-09-02

    Elemental levels and distributions in various organs (leaves, upright stems, rhizomes and roots) of the seagrass Thalassodendron ciliatum were determined using the NAC nuclear microprobe. Elemental distributions were obtained using the true elemental imaging system Dynamic Analysis (DA). Cl was the most abundant element present in the organs, occurring in all tissues, but present in relatively low concentrations in epidermal cells of leaves and roots. Na, K, S and Mg were also abundant and occurred in all organ tissues. Ca concentration was highest in the leaves, especially in the epidermis. Low concentrations of P were found and its tissue distribution was limited. Although Fe, Cu, Zn, Mn, Br, Ti and Si were present in relatively small amounts, enrichment of the epidermis with Fe, Ti and Si in all organs, was observed. Fe concentration was the highest in rhizomes while Si concentration was highest in upright stems. The significance of these elemental distribution patterns and the value of the nuclear microprobe in elemental analysis of seagrasses are discussed.

  9. Structural and electrical characterisation of semiconductor materials using a nuclear microprobe

    Jamieson, D.N.

    1998-01-01

    The domain of high-resolution imaging techniques (sub-micron) traditionally belongs to low-energy ion beams (ke V ion microprobe), electrons (transmission or scanning electron microscopy), light (near field microscopy), or all variants of scanning probe microscopies. Now, nuclear techniques of analysis, with a nuclear microprobe, have entered this domain, bringing a range of unique techniques for making images. In addition to-conventional techniques like Rutherford (and non-Rutherford) backscattering spectrometry and particle induced x-ray emission for structural characterisation, new ion beam analysis techniques have been developed for electrical characterisation as well. Foremost of these new techniques is ion beam induced charge (IBIC) which has seen an explosion of applications in the last five years to the study of charge transport properties of a variety of materials including polycrystalline diamond and silicon. An additional novel technique is ionoluminescence, which may be used to image various electronic properties of the material. Presented here are some examples of these imaging techniques in a variety of semiconductor materials. In all these examples, the specimens display structural inhomogeneities on the scale of 10 micrometres, making it essential to employ a focused beam. (author)

  10. Structural and electrical characterisation of semiconductor materials using a nuclear microprobe

    Jamieson, D.N. [Melbourne Univ., Parkville, VIC (Australia). School of Physics, Microanalytical Centre

    1998-06-01

    The domain of high-resolution imaging techniques (sub-micron) traditionally belongs to low-energy ion beams (ke V ion microprobe), electrons (transmission or scanning electron microscopy), light (near field microscopy), or all variants of scanning probe microscopies. Now, nuclear techniques of analysis, with a nuclear microprobe, have entered this domain, bringing a range of unique techniques for making images. In addition to-conventional techniques like Rutherford (and non-Rutherford) backscattering spectrometry and particle induced x-ray emission for structural characterisation, new ion beam analysis techniques have been developed for electrical characterisation as well. Foremost of these new techniques is ion beam induced charge (IBIC) which has seen an explosion of applications in the last five years to the study of charge transport properties of a variety of materials including polycrystalline diamond and silicon. An additional novel technique is ionoluminescence, which may be used to image various electronic properties of the material. Presented here are some examples of these imaging techniques in a variety of semiconductor materials. In all these examples, the specimens display structural inhomogeneities on the scale of 10 micrometres, making it essential to employ a focused beam. (author). Extended abstract. 18 refs. 4 figs.

  11. Impedance analysis of PbS colloidal quantum dot solar cells with different ZnO nanowire lengths

    Fukuda, Takeshi; Takahashi, Akihiro; Wang, Haibin; Takahira, Kazuya; Kubo, Takaya; Segawa, Hiroshi

    2018-03-01

    The photoconversion efficiency of colloidal quantum dot (QD) solar cells has been markedly improved by optimizing the surface passivation and device structure, and details of device physics are now under investigation. In this study, we investigated the resistance and capacitance components at the ZnO/PbS-QD interface and inside a PbS-QD layer by measuring the impedance spectrum while the interface area was controlled by changing the ZnO nanowire length. By evaluating the dependence of optical intensity and DC bias voltage on the ZnO nanowire length, only the capacitance was observed to be influenced by the interface area, and this indicates that photoinduced carriers are generated at the surface of PbS-QD. In addition, since the capacitance is proportional to the surface area of the QD, the interface area can be evaluated from the capacitance. Finally, photovoltaic performance was observed to increase with increasing ZnO nanowire length owing to the large interface area, and this result is in good agreement with the capacitance measurement.

  12. Ion microprobe imaging of 44Ca-labeled mammalian chromosomes

    Levi-Setti, R.; Gavrilov, K.L.; Strissel, P.L.; Strick, R.

    2004-01-01

    In our previous investigation, we showed for the first time high-resolution analytical images of the cation composition of mammalian interphase and mitotic cells as well as of isolated metaphase chromosomes using the University of Chicago scanning ion microprobe (UC-SIM). In order to preserve the ionic integrity of the analyzed cells and prevent the well known occurrence of analytical artifacts due to the high diffusivity of cations in biological samples we used fast cryo-preservation methods (freeze-drying and freeze fracture), without any pre-fixations or washes. We identified the role of the cations in chromosome structure and maintenance using SIMS imaging and immunfluorescence methodologies. Importantly, we determined that the above cations are essential participants in chromosome condensation and maintenance of chromatin higher order structure, through their presumed function in DNA electrostatic neutralization and the direct interaction of Ca 2+ , in particular, with structural proteins. In addition, both Ca 2+ and Mg 2+ showed the same cell cycle regulation where during interphase both cations were enriched in the cytosol, particularly in organelles then at mitosis became specifically bound to chromatin. Our present research interest focuses on a more detailed analysis of the distribution of Ca 2+ throughout the different cell cycle stages, e.g. G1, G2 and mitosis. We have chosen the stable isotope 44 Ca as a tracer to follow Ca 2+ throughout the cell cycle. This nuclide occurs naturally in the ratio 44 Ca/ 40 Ca+ 44 Ca of 2.06%, so that incorporation at higher concentrations into chromatin or other cellular components should be easily detected by SIMS. Such incorporation can be obtained either by growing cells in a medium where ordinary Ca is replaced entirely by 44 Ca, or by replacing the cell culture medium with the 44 Ca medium for a gated time span (pulsing), after appropriate cell cycle stage synchronization. In this paper, we describe our

  13. Review on influences of colloids on geologic disposal of high level radioactive waste. For better understanding of natural colloidal materials

    Kanai, Yutaka; Suzuki, Masaya; Kamioka, Hikari; Yoshida, Takahiro; Suko, Takeshi

    2007-01-01

    Although the influences of colloidal materials on radionuclide transport in geological media are pointed out, their behaviors in natural environment have not yet been well elucidated and therefore their influences on the geologic disposal of high-level radioactive waste (HLW) are not fully estimated quantitatively. This paper reviewed the studies on natural colloids, especially focused on inorganic, organic and biological colloids, and discussed the future works to be carried out. Much attention should be paid to the sampling and analysis. Excellent techniques for in-situ observation, concentration without changing the state of colloid, standard procedure for analysis, are necessary to be developed. More research studies on the behaviors of colloids are required in not only far- and near-fields but also items on effects of the environments and its evolution. (author)

  14. Colloid-templated multisectional porous polymeric fibers.

    Song, Jung Hun; Kretzschmar, Ilona

    2008-10-07

    A fabrication method for porous polymeric fibers (PPFs) is reported. We show that a multisectional colloidal crystal can be assembled within a microcapillary by alternating dipping into colloidal solutions of varying size. Subsequent infiltration with curable polymer and washing with suitable solvents results in porous fibers with a cylindrical cross section. Along the length of the fiber, alternating sections of controlled length, pore size, and pore size distribution exist. These fibers present interesting materials for neural scaffolding, catalysis, and possibly photonics if produced with a high degree of crystallinity. The surface pores and bulk porosity of the fibers are characterized by variable-pressure scanning electron microscopy (vp-SEM). Careful analysis shows that the surface pores vary with the colloidal template diameter and polymer infiltration time.

  15. Medical applications of colloids

    Matijevic, Egon

    2008-01-01

    The first book of its type on the medical and biomedical applications of colloids, although there are some related titles on different topicsDiscusses the effects of uniform particles in drug formulations and releaseEvaluates particle transport and deposition in the human body.

  16. Simulation of dense colloids

    Herrmann, H.J.; Harting, J.D.R.; Hecht, M.; Ben-Naim, E.

    2008-01-01

    We present in this proceeding recent large scale simulations of dense colloids. On one hand we simulate model clay consisting of nanometric aluminum oxide spheres in water using realistic DLVO potentials and a combination of MD and SRD. We find pronounced cluster formation and retrieve the shear

  17. Color electron microprobe cathodoluminescence of Bishunpur meteorite compared with the traditional optical microscopy method

    Amanda Araujo Tosi

    Full Text Available Abstract Cathodoluminescence (CL imaging is an outstanding method for sub classification of Unequilibrated Ordinary Chondrites (UOC - petrological type 3. CL can be obtained by several electron beam apparatuses. The traditional method uses an electron gun coupled to an optical microscope (OM. Although many scanning electron microscopes (SEM and electron microprobes (EPMA have been equipped with a cathodoluminescence, this technique was not fully explored. Images obtained by the two methods differ due to a different kind of signal acquisition. While in the CL-OM optical photography true colors are obtained, in the CL-EPMA the results are grayscale monochromatic electronic signals. L-RGB filters were used in the CL-EPMA analysis in order to obtain color data. The aim of this work is to compare cathodoluminescence data obtained from both techniques, optical microscope and electron microprobe, on the Bishunpur meteorite classified as LL 3.1 chondrite. The present study allows concluding that 20 KeV and 7 nA is the best analytical condition at EPMA in order to test the equivalence between CL-EPMA and CL-OM colour results. Moreover, the color index revealed to be a method for aiding the study of the thermal metamorphism, but it is not definitive for the meteorite classification.

  18. Optical system optimization of the microprobe beamline of the Ion Implantation Laboratory (IF-UFRGS), Brazil

    Bauer, Deiverti de Vila

    2015-01-01

    The aim of the present work is to optimize the microprobe beamline of the Ion Implantation Laboratory (IF-UFRGS). In short, an ion microprobe consists of charged particles focused to the dimensions of a few micrometers. The focusing system is made of two slits for demagnification, a set of magnetic lenses with scanning capability and a reaction chamber. By changing the parameters related to this system, one can optimize the features of the beam. To that end, samples of poly(tereftalate etylene) were irradiated with 2.2 MeV H+ ions and etched, yielding 2D microstructures with high aspect ratio. The analysis of the structures with Scanning Electron Microscopy proved to be an important tool in order to establish a correlation between the size of the microstructures and the parameters of the focusing system. In this work, the causes leading to a beam enlargement are discussed, as well as the aberrations which affect the system. Finally, the advantages of using ions for lithography purposes is pointed out. (author)

  19. A tunable x-ray microprobe using synchrotron radiation

    Wu, Y.; Thompson, A.C.; Underwood, J.H.; Giauque, R.D.; Chapman, K.; Rivers, M.L.; Jones, K.W.

    1989-08-01

    We describe an x-ray microprobe using multilayer mirrors. Previously, we had demonstrated a Kirkpatrick-Baez type focusing system working at both 8 and 10 keV and successfully applied it to a variety of applications, including the determination of elemental contents in fluid inclusions. In this paper, we show that the usable excitation energy for this microprobe is not restricted to between 8 and 10 keV, and furthermore, it can be simply tuned in operation. A 10-keV x-ray fluorescence microprobe can be used to measure the concentration of the elements form potassium (Z = 19) to zinc (Z = 30) using K x-ray lines, and from cadmium (Z = 48) to erbium (Z = 68) using L x-ray lines. There are a number of geologically important elements in the gap between gallium (Z = 31) and silver(Z = 47) and also with Z > 68. In order to cover this range, a higher excitation energy is required. On the other hand, for samples that contain major elements with absorption edges lower than the excitation energy, it would be hard to detect other mirror elements because of the strong signal from the major elements and the background they produce. In this case, a tunable x-ray source can be used to avoid the excitation of the major elements. We demonstrate that, with the existing setup, it is possible to tune the excitation energy from 6 keV to 14 keV, in this range, the intensity does not decrease by more than one order of magnitude. As an illustration, a geological sample was examined by using two different excitation energy range as well as the possibility of improving the intensity. 11 refs., 5 figs

  20. Spectral force analysis using atomic force microscopy reveals the importance of surface heterogeneity in bacterial and colloid adhesion to engineered surfaces.

    Ma, Huilian; Winslow, Charles J; Logan, Bruce E

    2008-04-01

    Coatings developed to reduce biofouling of engineered surfaces do not always perform as expected based on their native properties. One reason is that a relatively small number of highly adhesive sites, or the heterogeneity of the coated surface, may control the overall response of the system to initial bacterial deposition. It is shown here using an approach we call spectral force analysis (SFA), based on force volume imaging of the surface with atomic force microscopy, that the behavior of surfaces and coatings can be better understood relative to bacterial adhesion. The application of vapor deposited TiO(2) metal oxide increased bacterial and colloid adhesion, but coating the surface with silica oxide reduced adhesion in a manner consistent with SFA based on analysis of the "stickiest" sites. Application of a TiO(2)-based paint to a surface produced a relatively non-fouling surface. Addition of a hydrophilic layer coating to this surface should have decreased fouling. However, it was observed that this coating actually increased fouling. Using SFA it was shown that the reason for the increased adhesion of bacteria and particles to the hydrophilic layer was that the surface produced by this coating was highly heterogeneous, resulting in a small number of sites that created a stickier surface. These results show that while it is important to manufacture surfaces with coatings that are relatively non-adhesive to bacteria, it is also essential that these coatings have a highly uniform surface chemistry.

  1. X-ray microprobe for the microcharacterization of materials

    Sparks, C.J.; Ice, G.E.

    1988-01-01

    The unique properties of x rays offer many advantages over those of electrons and other charged particles for the microcharacterization of materials. X rays are more efficient in exciting characteristic x-ray fluorescence and produce higher fluorescent signal-to-background ratios than obtained with electrons. Such x-ray microprobes will also produce unprecedentedly low levels of detection in diffraction, EXAFS, Auger, and photoelectron spectroscopies for structural and chemical characterization and elemental identification. These major improvements in microcharacterization capabilities will have wide-ranging ramifications not only in materials science but also in physics, chemistry, geochemistry, biology, and medicine. 24 refs., 6 figs., 2 tabs

  2. Enhancements to the analytical facilities at the GNS proton microprobe

    Barry, B.J.; Markwitz, A.; Kennedy, V.J.; Trompetter, W.J.

    2005-01-01

    In recent years a number of detection systems have been added to the proton microprobe facility at GNS Science. Particular additions have been a large area HPGe detector and a system for scanning transmission imaging microscopy. The HPGe detector has improved detection sensitivity, particularly for higher energy K x-rays where energy resolution is of lesser importance. The scanning microscopy system has enabled mapping of areal densities in biological samples to give accurate elemental maps. Examples are given of these applications. (author). 22 refs., 7 figs

  3. Operation and acquisition automation of a nuclear microprobe

    Simond, Isabelle

    1990-01-01

    The purpose of this work was to design the hardware and the software parts of data acquisition and its graphical analyses of a nuclear microprobe. Our realisation was built from a microprocessor 68020 and specialized co-processors on a VME bus. The more important demand was the amount of time required to collect the data and to perform the graphical analyses during the acquisition. To overcome this problem, we adapted a real time operating system and its kernel to our need, and built special graphical processes. (author) [fr

  4. Trans-Regional technologies and the Lapita problem: characterisation of volcanic glass inclusions by electron microprobe

    Grave, P.; Nockolds, C.; White, P.

    1997-01-01

    Full text: Analysis of pre-modern pottery of the Pacific has long attempted to formulate measures independent of style for constructing archaeologically meaningful groups. However, the variable character of fabrics and the longevity of production (Lapita and post-Lapita wares from 3000 years ago to the present) have tended to obscure differences due to changes in production practices and resources through time and differences relating to the exchange of ceramics between islands or regions. In this poster we outline a preliminary study that employs an economical and robust technique to distinguish both within- and between-region groups. This is achieved with electron microprobe analysis of small volcanic glass fragments present in wares tempered with volcanic sands, and interpretation based on Principal Components Analysis. The method builds on the chemical groupings for glass from different volcanic complexes in the Pacific established through high energy ion beam (PIXE-PIGME) analysis. The purpose of this study is to characterise a selection of samples of pottery from the Duke of York's peninsula using electron microprobe analysis of very small glass fragments in the sections that ranged in size from around 0.05 mm to 1 mm.. The study involved the identification and elemental characterisation of individual fragments of glass in a section. Principal Component Analysis was used to identify structure latent in the dataset. The results of the study show that clear characterisation is possible to enable the wider application of the technique to Lapita and post Lapita ceramics produced originating in volcanic areas of the Pacific

  5. A study on the formation and transport of radioactive colloids in porous media

    Chung, Jin Yop

    1992-02-01

    Colloid particles, which may be supplied naturally by groundwater, are shown to be important potential vehicles for the transport of radionuclides in geologic media. Colloid particles have also large available sites for adsorption because small particles have high surface areas per unit mass. This possibility leads us to investigate the controlling factors of colloids in groundwater to simulate the radionuclide behavior at the repository. Analytical models that can be generalized for the purpose, however, are not available yet. Therefore, in this study the mechanisms that affect the colloid transport were reviewed carefully and, also in order to evaluate the extent of their effects, general and analytical model combined with modified filtration equation was developed. This modified filtration equation including colloidal particle size effect was solved as a function of colloidal particle size, which is a important factor affecting the colloidal transport, grain diameter of porous media, groundwater velocity, distance, and time. Also, as another measure to estimate colloidal particle size effect, analytical method to calculate the adsorption of radionuclides on the colloid, concepts of transport velocity and migration distance were introduced. To evaluate the relative contribution of colloid to the radionuclide transport quatitatively, colloidal transport was compared with the corresponding solute transport under same conditions. Finally, the three phase analysis was proposed to treat the radionuclide transport more practically. A good agreement was obtained between the predicted result by modified filtration equation and the corresponding published experimental data. As the colloidal size is increased, the effect of diffusional velocity on the mobility decreases and that of gravitational settling increases, respectively, whereas the mobility reduction due to filtration increases when interception and gravitational settling dominate. Results of case studies about

  6. Patterned Colloidal Photonic Crystals.

    Hou, Jue; Li, Mingzhu; Song, Yanlin

    2018-03-01

    Colloidal photonic crystals (PCs) have been well developed because they are easy to prepare, cost-effective, and versatile with regards to modification and functionalization. Patterned colloidal PCs contribute a novel approach to constructing high-performance PC devices with unique structures and specific functions. In this review, an overview of the strategies for fabricating patterned colloidal PCs, including patterned substrate-induced assembly, inkjet printing, and selective immobilization and modification, is presented. The advantages of patterned PC devices are also discussed in detail, for example, improved detection sensitivity and response speed of the sensors, control over the flow direction and wicking rate of microfluidic channels, recognition of cross-reactive molecules through an array-patterned microchip, fabrication of display devices with tunable patterns, well-arranged RGB units, and wide viewing-angles, and the ability to construct anti-counterfeiting devices with different security strategies. Finally, the perspective of future developments and challenges is presented. © 2018 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  7. Flocking ferromagnetic colloids.

    Kaiser, Andreas; Snezhko, Alexey; Aranson, Igor S

    2017-02-01

    Assemblages of microscopic colloidal particles exhibit fascinating collective motion when energized by electric or magnetic fields. The behaviors range from coherent vortical motion to phase separation and dynamic self-assembly. Although colloidal systems are relatively simple, understanding their collective response, especially under out-of-equilibrium conditions, remains elusive. We report on the emergence of flocking and global rotation in the system of rolling ferromagnetic microparticles energized by a vertical alternating magnetic field. By combing experiments and discrete particle simulations, we have identified primary physical mechanisms, leading to the emergence of large-scale collective motion: spontaneous symmetry breaking of the clockwise/counterclockwise particle rotation, collisional alignment of particle velocities, and random particle reorientations due to shape imperfections. We have also shown that hydrodynamic interactions between the particles do not have a qualitative effect on the collective dynamics. Our findings shed light on the onset of spatial and temporal coherence in a large class of active systems, both synthetic (colloids, swarms of robots, and biopolymers) and living (suspensions of bacteria, cell colonies, and bird flocks).

  8. Ion beam induced luminescence from diamond using an MeV ion microprobe

    Bettiol, A A; Jamieson, D N; Prawer, S; Allen, M G [Melbourne Univ., Parkville, VIC (Australia). School of Physics

    1994-12-31

    Analysis of the luminescence induced by a MeV ion beam offers the potential to provide useful information about the chemical properties of atoms in crystals to complement the information provided by more traditional Ion Beam Analysis (IBA) such as Rutherford Backscattering Spectrometry (RBS), ion channeling and Particle Induced X-ray Emission (PIXE). Furthermore, the large penetration depth of the MeV ion beam offers several advantages over the relatively shallow penetration of keV electrons typically employed in cathodoluminescence. An Ion Beam Induced Luminescence (IBIL) detection system was developed for the Melbourne microprobe that allows the spatial mapping of the luminescence signal along with the signals from RBS and PIXE. Homoepitaxial diamond growth has been studied and remarkable shifts in the characteristic blue luminescence of diamond towards the green were observed in the overgrowth. This has been tentatively identified as being due to transition metal inclusions in the epitaxial layers. 8 refs., 2 refs.

  9. Ion beam induced luminescence from diamond using an MeV ion microprobe

    Bettiol, A.A.; Jamieson, D. N.; Prawer, S.; Allen, M.G. [Melbourne Univ., Parkville, VIC (Australia). School of Physics

    1993-12-31

    Analysis of the luminescence induced by a MeV ion beam offers the potential to provide useful information about the chemical properties of atoms in crystals to complement the information provided by more traditional Ion Beam Analysis (IBA) such as Rutherford Backscattering Spectrometry (RBS), ion channeling and Particle Induced X-ray Emission (PIXE). Furthermore, the large penetration depth of the MeV ion beam offers several advantages over the relatively shallow penetration of keV electrons typically employed in cathodoluminescence. An Ion Beam Induced Luminescence (IBIL) detection system was developed for the Melbourne microprobe that allows the spatial mapping of the luminescence signal along with the signals from RBS and PIXE. Homoepitaxial diamond growth has been studied and remarkable shifts in the characteristic blue luminescence of diamond towards the green were observed in the overgrowth. This has been tentatively identified as being due to transition metal inclusions in the epitaxial layers. 8 refs., 2 refs.

  10. Present status of research and development on X-ray microprobe

    Koike, Masaki; Suzuki, I.H.

    1991-01-01

    X-ray beam micro-analysis has advanced rapidly in these years in conjunction with the development of powerful X-ray sources. Among a variety of methods being attempted, the method using a collimated narrow beam has been important because of high brightness, and of usability in both regions of soft and hard X-rays. In the soft X-ray region, the focused beam is formed by a fresnel zone plate or a Schwaltzschild mirror assembly, and can be used for scanning transmission microscope or scanning photoelectron microscope. In the hard X-ray region, the beam is formed by grazing incidence mirrors, and can be used for X-ray fluorescence micro-analysis for obtaining elemental mapping. In this report, the recent progress on the soft X-ray scanning microscopy and the X-ray microprobe has been surveyed, together with the improvement on the related optical elements. (author) 84 refs

  11. Colloid migration in fractured media

    Hunt, J.R.

    1989-01-01

    Field studies at the Nevada Test Site by researchers at Lawrence Livermore National Laboratory have demonstrated that radionuclides are being transported by colloidal material suspended in groundwater. This observation is counter to most predictions from contaminant transport models because the models assume adsorbed species are immobile. The purpose of this research is to quantify the transport processes for colloidal materials and develop the mechanistic understanding necessary to predict radionuclide transport in fractured media. There were three areas of investigation during this year that have addressed these issues: chemical control of colloid deposition on clean mineral surfaces, colloid accumulation on fracture surfaces, and the influence of deposited colloids on colloid and tracer migration. 7 refs

  12. Realtime control system for microprobe beamline at PLS

    Yoon, J.C.; Lee, J.W.; Kim, K.H.; Ko, I.S. [Pohang Accelerator Laboratory, POSTECH, Pohang (Korea)

    1998-11-01

    The microprobe beamline of the Pohang Light Source (PLS) consists of main and second slits, a microprobe system, two ion chambers, a video-microscope, and a Si(Li) detector. These machine components must be controlled remodely through the computer system to make user's experiments precise and speedy. A real-time computer control system was developed to control and monitor these components. A VMEbus computer with an OS-9 real-time operating system was used for the low-level data acquisition and control. VME I/O modules were used for the step motor control and the scalar control. The software has a modular structure for the maximum performance and the easy maintenance. We developed the database, the I/O driver, and the control software. We used PC/Windows 95 for the data logging and the operator interface. Visual C{sup ++} was used for the graphical user interface programming. RS232C was used for the communication between the VME and the PC. (author)

  13. Characterization of PE-g-HEMA films prepared by gamma irradiation through nuclear microprobe techniques

    Ferreira, L.M.; Rodrigues, P.A.; Falcao, A.N.; Leal, J.P.

    2011-01-01

    Complete text of publication follows. The functional success of a copolymer as biomaterial depends fundamentally on their mechanical properties (stemming from the material matrix) and on the characteristics of its surface. For biomedical applications, among all the other important properties, the biocompatibility of the surface acquires extreme importance and can dictate its rejection. One of the issues regarding biocompatibility is cytotoxicity which strongly depends on the contamination level at surface. Ion beam analysis techniques associated to Nuclear Microprobe (PIXE, RBS and STIM) allows a rigorous and precise analysis of the concentration (ppm) and distribution of elements contamination, and may also provide information on its near-surface structure. In this work PE-g-HEMA films with different grafting yields were prepared by mutual gamma irradiation at a 60 Co source and were analyzed through nuclear microprobe. Data collected allowed the qualitative and quantitative evaluation of contaminants distribution observed in the different samples as well as the clarification of some processes occurred during the copolymerization reaction. Qualitative analysis showed a random and no homogeneous distribution of the contaminant elements, independent of the grafting degree, suggesting the existence of several sources of contamination at different stages of their preparation. Results also suggest that this 'phased' contamination occurs simultaneously with mechanisms of agglomeration/entrapment of impurities during the gamma induced copolymerization reaction. Moreover, quantitative data showed that all contaminants found in the copolymeric films are natural contaminants of their reagents of preparation, although at concentrations without toxicological hazard, which points to a low cytotoxic potential. The combined analysis of these data with data from SEM and AFM allowed a better understanding of the surface structure and other properties already observed in these

  14. Comparison of laser microprobe mass spectrometry (LMMS) and micro particle induced x-ray emission (micro-PIXE) for the analysis of senile plaques in Alzheimer`s disease. A preliminary study

    Lovell, M A; Robertson, J D; Ehmann, W D [Kentucky Univ., Lexington, KY (United States). Dept. of Chemistry; Markesbery, W R [Kentucky Univ., Lexington, KY (United States); Teesdale, W J; Campbell, J L [Guelph Univ., ON (Canada). Dept. of Physics

    1995-08-01

    Results of micro-PIXE analysis of senile plaques (SP) in Alzheimer`s disease (AD) brain have been utilized to independently confirm levels of iron (Fe) as measured by LMMS in adjacent brain sections. LMMS concentrations were calculated based on the preparation and analysis of an iron calibration curve prepared in our laboratory. The LMMS standards consist of iron cis-dicylclohexano-18-crown-6 ether coordination complexes dissolved in Spurr`s low viscosity embedding medium. To our knowledge, this is the first report of the use of micro-PIXE, with its spatial resolution and detection limits comparable to that of LMMS, in the validation of LMMS results. The agreement observed between results obtained for Fe by micro-PIXE and LMMS indicates that the use of our LMMS standards, at least in the case of Fe, yields accurate results. (author). 6 refs., 1 fig., 1 tab.

  15. General theory of three-dimensional radiance measurements with optical microprobes RID A-1977-2009

    FukshanskyKazarinova, N.; Fukshansky, L.; Kuhl, M.

    1997-01-01

    Measurements of the radiance distribution and fluence rate within turbid samples with fiber-optic radiance microprobes contain a large variable instrumental error caused by the nonuniform directional sensitivity of the microprobes. A general theory of three-dimensional radiance measurements...

  16. Growth and Interaction of Colloid Nuclei

    Lam, Michael-Angelo; Khusid, Boris; Meyer, William; Kondic, Lou

    2017-11-01

    We study evolution of colloid systems under zero-gravity conditions. In particular, we focus on the regime where there is a coexistence between a liquid and a solid state. Under zero gravity, the dominating process in the bulk of the fluid phase and the solid phase is diffusion. At the moving solid/liquid interface, osmotic pressure is balanced by surface tension, as well as balancing fluxes (conservation of mass) with the kinematics of nuclei growth (Wilson-Frenkel law). Due to the highly nonlinear boundary condition at the moving boundary, care has to be taken when performing numerical simulations. In this work, we present a nonlinear model for colloid nuclei growth. Numerical simulations using a finite volume method are compared with asymptotic analysis of the governing equation and experimental results for nuclei growth. Novel component in our numerical simulations is the inclusion of nonlinear (collective) diffusion terms that depend on the chemical potentials of the colloid in the solid and fluid phase. The results include growth and dissolution of a single colloidal nucleus, as well as evolution of multiple interacting nuclei. Supported by NASA Grant No. NNX16AQ79G.

  17. Progress of the new CSIRO-GEMOC nuclear microprobe: first results, performance and recent applications

    Ryan, C.G.; Cripps, G.; Sie, S.H.; Suter, G.F.; Jamieson, D.N.; Griffin, W.L.; Commonwealth Scientific and Industrial Research Organisation

    1999-01-01

    The new CSIRO-GEMOC Nuclear Microprobe (NMP) features a number of technical advances for high resolution, high sensitivity microanalysis. It was designed at the CSIRO and developed as collaboration between the CSlRO, the GEMOC key-centre at Macquarie University and the MARC group of the University of Melbourne. For imaging applications, it also features a software system using a powerful algorithm called Dynamic Analysis, developed at the CSIRO for unmixing elemental signatures in proton induced X-ray emission (PIXE) data, to provide a tool for rapid quantitative imaging of trace and major element spatial distribution in minerals. This paper reports on the performance of the NMP and examples of its application over the past 6 months since completion

  18. Trace element composition and distribution in micron area of dinosaur eggshell fossils determined by proton microprobe

    Chen Youhong; Zhu Jieqing; Wang Xiaohong; Wang Yimin

    1997-01-01

    The scanning proton microprobe and micro-PIXE quantitative analysis technique have been used to determine composition and distribution of the trace elements in micron areas of dinosaur eggshell fossils from the stratum of Upper Cretaceous system at Nanxiong Basin in Guangdong Province, China. The study shows that the trace elements mainly include Ti, V, Cr, Mn, Co, Ni, Cu, Zn, As, Rb, Sr, Y, Zr, Sb, Ba and Pb in the micron area, but they present different distributions. While the element Sr is mainly enriched in the near surface layer, others mainly reside in the near inner layer. A preliminary discussion on the reason of the dinosaur extinction is given based on the above study

  19. Trace element composition and distribution in micron area of dinosaur eggshell fossils determined by proton microprobe

    Chen Youhong; Zhu Jieqing; Wang Xiaohong; Wang Yimin

    1997-01-01

    The scanning proton microprobe and micro-PIXE quantitative analysis technique have been used to determine composition and distribution of the trace elements in micron areas of dinosaur eggshell fossils from the stratum of Upper Cretaceous system at Nanxiong Basin in Guangdong Province, China. The study shows that the trace elements mainly include Ti, V, Cr, Mn, Co, Ni, Cu, Zn, As, Rb, Sr, Y, Zr, Sb, Ba and Pb in the micron area, but they present different distributions. While the elements Sr is mainly enriched in the near surface layer, others mainly reside in the near inner layer. A preliminary discussion on the reason of the dinosaur extinction is given based on the above study

  20. Microprobe study of fission product behavior in high-burnup HTR fuels

    Kleykamp, H.

    Electron microprobe analysis of irradiated coated particles with high burnup (greater than 50 percent fima) gives detailed information on the chemical state and the transport behavior of the fission products in UO 2 and UC 2 kernels and in the coatings. In oxide fuel kernels, metallic inclusions and ceramic precipitations are observed. The solubility behavior of the fission products in the fuel matrix has been investigated. Fission product inclusions could not be detected in carbide fuel kernels; post irradiation annealed UC 2 kernels, however, give information on the element combinations of some fission product phases. Corresponding to the chemical state in the kernel, Cs, Sr, Ba, Pd, Te and the rare earths are released easily and diffuse through the entire pyrocarbon coating. These fission products can be retained by a silicon carbide layer. The initial stage of a corrosive attack of the SiC coating by the fission products is evidenced

  1. Structure and stability of charged colloid-nanoparticle mixtures

    Weight, Braden M.; Denton, Alan R.

    2018-03-01

    Physical properties of colloidal materials can be modified by addition of nanoparticles. Within a model of like-charged mixtures of particles governed by effective electrostatic interactions, we explore the influence of charged nanoparticles on the structure and thermodynamic phase stability of charge-stabilized colloidal suspensions. Focusing on salt-free mixtures of particles of high size and charge asymmetry, interacting via repulsive Yukawa effective pair potentials, we perform molecular dynamics simulations and compute radial distribution functions and static structure factors. Analysis of these structural properties indicates that increasing the charge and concentration of nanoparticles progressively weakens correlations between charged colloids. We show that addition of charged nanoparticles to a suspension of like-charged colloids can induce a colloidal crystal to melt and can facilitate aggregation of a fluid suspension due to attractive van der Waals interactions. We attribute the destabilizing influence of charged nanoparticles to enhanced screening of electrostatic interactions, which weakens repulsion between charged colloids. This interpretation is consistent with recent predictions of an effective interaction theory of charged colloid-nanoparticle mixtures.

  2. Polymers and colloids

    Schurtenberger, P.

    1996-01-01

    A wealth of structural information from colloid and polymer solutions on a large range of length scales can be obtained using small angle neutron scattering (SANS) experiments. After a general introduction to the field of soft condensed matter, I shall give a few selected examples on how SANS combined with suitable contrast variation schemes can be used to extract information on the size and conformation of polymer coils in solution and in the melt, and on the local structure and flexibility of polymerlike micelles and microemulsions. (author) 8 figs., tabs., 44 refs

  3. Polymers and colloids

    Schurtenberger, P [ETH Zurich, Inst. fuer Polymere, Zurich (Switzerland)

    1996-11-01

    A wealth of structural information from colloid and polymer solutions on a large range of length scales can be obtained using small angle neutron scattering (SANS) experiments. After a general introduction to the field of soft condensed matter, I shall give a few selected examples on how SANS combined with suitable contrast variation schemes can be used to extract information on the size and conformation of polymer coils in solution and in the melt, and on the local structure and flexibility of polymerlike micelles and microemulsions. (author) 8 figs., tabs., 44 refs.

  4. Quantification of the distribution of hydrogen by nuclear microprobe at the Laboratory Pierre Sue in the width of zirconium alloy fuel clad of PWR reactors

    Raepsaet, C.; Bossis, Ph.; Hamon, D.; Bechade, J.L.; Brachet, J.C.

    2007-01-01

    Among the analysis techniques by ions beams, the micro ERDA (Elastic Detection Analysis) is an interesting technique which allows the quantitative distribution of the hydrogen in materials. In particular, this analysis has been used for hydride zirconium alloys, with the nuclear microprobe of the Laboratory Pierre Sue. This probe allows the characterization of radioactive materials. The technique principles are recalled and then two examples are provided to illustrate the fuel clad behavior in PWR reactors. (A.L.B.)

  5. Implementation of ionoluminescence in the AGLAE scanning external microprobe

    Pichon, L.; Calligaro, T.; Gonzalez, V.; Lemasson, Q.; Moignard, B.; Pacheco, C.

    2015-01-01

    The scope of this work is to present the implementation of an IBIL imaging system in the scanning external microprobe of the AGLAE facility so as to correlate luminescence and composition maps provided by PIXE, RBS and PIGE. The challenging integration of the optical spectrometer, due to incompatibility of acquisition timings and data formats with the other IBA channels has motivated the development of a specific acquisition system. This article details the IBIL setup and explains the technical solutions retained for the coupling of IBIL with IBA techniques in order to produce fast and large IBIL-IBA maps. The IBIL maps stored in the same format as the PIXE, RBS and PIGE ones can be visualised and compared using the dedicated AGLAEmap program or the PyMCA processing package. An example of such a coupled mapping on Mesoamerican jade is presented to emphasise the interest of performing simultaneously IBA and IBIL large mappings

  6. Wireless cardiac action potential transmission with ultrasonically inserted silicon microprobes

    Shen, C J; Ramkumar, A; Lal, A; Gilmour, R F Jr

    2011-01-01

    This paper reports on the integration of ultrasonically inserted horn-shaped cardiac probes with wireless transmission of 3D cardiac action potential measurement for applications in ex vivo preparations such as monitoring the onset of ventricular fibrillation. Ultrasonically inserted silicon horn probes permit reduced penetration force during insertion, allowing silicon, a brittle material, to penetrate cardiac tissue. The probes also allow recording from multiple sites that are lithographically defined. An application-specific integrated circuit has been designed with a 40 dB amplifying stage and a frequency modulating oscillator at 95 MHz to wirelessly transmit the recorded action potentials. This ultrasonically inserted microprobe wireless system demonstrates the initial results in wireless monitoring of 3D action potential propagation, and the extraction of parameters of interest including the action potential duration and diastolic interval

  7. Data acquisition for X ray microprobe. User's manual

    2002-01-01

    A modified data acquisition software for X ray microprobe was developed by the Physics Group, Instrumentation Unit, IAEA Laboratories at Seibersdorf, with assistance from M. Bogovac, Croatia. The software consists of data acquisition (scanning and calibration), automatic positioning and micro-movement of sample, data reduction and evaluation. The acquisition software was designed in order to support different measurement set-ups which are applied in low-energy nuclear physics. The modification was done in 1999-2000 under the projects Nuclear Spectrometry and Utilization of Particle Accelerators. The manual supersedes the first version entitled Microanalysis Data Acquisition and Control Program published under Computer Manual Series, No. 9 in 1996. The software described in this manual is freely available from the IAEA upon request

  8. Ion microprobe U-Pb dating of a dinosaur tooth

    Sano, Yuji; Terada, Kentaro; Ly, Chi V.; Park, Eun Ju

    2006-01-01

    Ion microprobe U-Pb dating of apatite is applied to a fossil tooth of a Allosaurid derived from the Hasandong Formation in the Gyeongsang basin, southeastern Korea. Twelve spots on a single fragment of the fossil dentine yield a Tera-Wasserburg concordia intercept age of 115±10 Ma (2σ, MSWD=0.59) on a 238 U/ 206 Pb- 207 Pb/ 206 Pb- 204 Pb/ 206 Pb diagram. The age provides a constraint on the depositional age of the fossil in its host Hassandong Formation as Early Aptian. The success of the ion microprobe dating depends on the heterogeneities of diagenetically incorporated U and Pb at the few hundred μm scale, the consequent variations in Pb isotopic compositions due to radioactive decay and the closed-system behavior of U and Pb. There are at least three end-members to explain the variations of minor chemical components such as FeO, SiO 2 and Al 2 O 3 , and trace elements as Th, U and rare earth elements (REE) in the sample by a simple mixing model. They are (1) very low minor and REE, very high common Pb with variable U abundances, (2) low common Pb, high minor, REE, and U abundances, and (3) low minor, common Pb, and U with intermediate REE abundances, even though groups (2) and (3) may consist of a larger group. Various contributions of the three (and/or two) end-members during diagenetic processes may cause the elemental fractionation of U and Pb in a fossil tooth. (author)

  9. Determination of radiochemical purity and pharmacokinetic parameters of sup(99m)Tc-sulphur colloid and sup(99m)Tc-tin colloid

    Jovanovic, V.; Konstantinovska, D.; Milivojevic, K.; Bzenic, J.

    1981-01-01

    Labelling yield and radiochemical purity, higher than 95%, of sup(99m)Tc-colloid preparations were determined by using the paper chromatography method. Less than 3% of labelled citric acid, added to the preparation as a buffer solution, has been found in sup(99m)Tc-sulphur colloid. High radiochemical purity and optimum size of colloid particles has also been proved by biodistribution studies on experimental animals. The analysis performed has shown that more than 50% of sup(99m)Tc-colloid preparations excreted by urine is sup(99m)TcO - , the remaining past 50% being protein bound sup(99m)Tc. Biological half-time of excretion of the fast phase is the same for both preparations, i.e. 10 min, while for the slow component it is 120 min in sup(99m)Tc-S-colloid and 160 min in sup(99m)Tc-Sn colloid. (orig.) [de

  10. Element analysis with a proton microprobe of early atherosclerotic lesions

    Roijers, R.B.

    2009-01-01

    Atherosclerosis is a progressive inflammatory vascular disease accompanied by a gradual build-up of cholesterol in the artery walls. The associated chronic inflammatory process leads to tissue damage in the vascular wall as a consequence of an excessive inflammatory response. Large calcified

  11. Characterization of natural colloids sampled from a fractured granite groundwater

    Baik, Min Hoon; Keum, Dong Kwon; Hahn, Pil Soo [Korea Atomic Energy Research Institute, Taejeon (Korea); Vilks, Peter [AECL Whiteshell Laboratories (Canada)

    2000-02-01

    This study was carried out as a part of international joint study of KAERI with AECL. The main purpose of this study is to analyze the physicochemical characteristics and sorption properties of natural colloids sampled from the deep fractured granite groundwater located in the Underground Research Laboratory (URL) of AECL. Physicochemical characteristics such as composition, size distribution, and concentrations of natural colloids was analyzed. This study will be basic data for the analysis of the effect of colloids on the radionuclide migration in a geological medium. This study may provide information for the evaluation of the roles and effects of colloids in the safety and performance assessment of a possible future radioactive waste repository. 20 refs., 8 figs., 8 tabs. (Author)

  12. Microrheology of colloidal systems

    Puertas, A M; Voigtmann, T

    2014-01-01

    Microrheology was proposed almost twenty years ago as a technique to obtain rheological properties in soft matter from the microscopic motion of colloidal tracers used as probes, either freely diffusing in the host medium, or subjected to external forces. The former case is known as passive microrheology, and is based on generalizations of the Stokes–Einstein relation between the friction experienced by the probe and the host-fluid viscosity. The latter is termed active microrheology, and extends the measurement of the friction coefficient to the nonlinear-response regime of strongly driven probes. In this review article, we discuss theoretical models available in the literature for both passive and active microrheology, focusing on the case of single-probe motion in model colloidal host media. A brief overview of the theory of passive microrheology is given, starting from the work of Mason and Weitz. Further developments include refined models of the host suspension beyond that of a Newtonian-fluid continuum, and the investigation of probe-size effects. Active microrheology is described starting from microscopic equations of motion for the whole system including both the host-fluid particles and the tracer; the many-body Smoluchowski equation for the case of colloidal suspensions. At low fluid densities, this can be simplified to a two-particle equation that allows the calculation of the friction coefficient with the input of the density distribution around the tracer, as shown by Brady and coworkers. The results need to be upscaled to agree with simulations at moderate density, in both the case of pulling the tracer with a constant force or dragging it at a constant velocity. The full many-particle equation has been tackled by Fuchs and coworkers, using a mode-coupling approximation and the scheme of integration through transients, valid at high densities. A localization transition is predicted for a probe embedded in a glass-forming host suspension. The

  13. Osmotic virial coefficients for model protein and colloidal solutions: Importance of ensemble constraints in the analysis of light scattering data

    Siderius, Daniel W.; Krekelberg, William P.; Roberts, Christopher J.; Shen, Vincent K.

    2012-05-01

    Protein-protein interactions in solution may be quantified by the osmotic second virial coefficient (OSVC), which can be measured by various experimental techniques including light scattering. Analysis of Rayleigh light scattering measurements from such experiments requires identification of a scattering volume and the thermodynamic constraints imposed on that volume, i.e., the statistical mechanical ensemble in which light scattering occurs. Depending on the set of constraints imposed on the scattering volume, one can obtain either an apparent OSVC, A2,app, or the true thermodynamic OSVC, {B_{22}^{osm}}, that is rigorously defined in solution theory [M. A. Blanco, E. Sahin, Y. Li, and C. J. Roberts, J. Chem. Phys. 134, 225103 (2011), 10.1063/1.3596726]. However, it is unclear to what extent A2,app and {B_{22}^{osm}} differ, which may have implications on the physical interpretation of OSVC measurements from light scattering experiments. In this paper, we use the multicomponent hard-sphere model and a well-known equation of state to directly compare A2,app and {B_{22}^{osm}}. Our results from the hard-sphere equation of state indicate that A2,app underestimates {B_{22}^{osm}}, but in a systematic manner that may be explained using fundamental thermodynamic expressions for the two OSVCs. The difference between A2,app and {B_{22}^{osm}} may be quantitatively significant, but may also be obscured in experimental application by statistical uncertainty or non-steric interactions. Consequently, the two OSVCs that arise in the analysis of light scattering measurements do formally differ, but in a manner that may not be detectable in actual application.

  14. Liquid crystal boojum-colloids

    Tasinkevych, M; Silvestre, N M; Telo da Gama, M M

    2012-01-01

    Colloidal particles dispersed in a liquid crystal (LC) lead to distortions of the director field. The distortions are responsible for long-range effective colloidal interactions whose asymptotic behaviour is well understood. The short-distance behaviour depends on the structure and dynamics of the topological defects nucleated near the colloidal particles and a full nonlinear theory is required to describe it. Spherical colloidal particles with strong planar degenerate anchoring nucleate a pair of antipodal surface topological defects, known as boojums. We use the Landau-de Gennes theory to resolve the mesoscopic structure of the boojum cores and to determine the pairwise colloidal interactions. We compare the results in three (3D) and two (2D) spatial dimensions for spherical and disc-like colloidal particles, respectively. The corresponding free energy functionals are minimized numerically using finite elements with adaptive meshes. Boojums are always point-like in 2D, but acquire a rather complex structure in 3D, which depends on the combination of the anchoring potential, the radius of the colloid, the temperature and the LC elastic anisotropy. We identify three types of defect cores in 3D that we call single, double and split-core boojums, and investigate the associated structural transitions. The split-core structure is favoured by low temperatures, strong anchoring and small twist to splay or bend ratios. For sufficiently strong anchoring potentials characterized by a well-defined uniaxial minimum, the split-core boojums are the only stable configuration. In the presence of two colloidal particles, we observe substantial re-arrangements of the inner defects in both 3D and 2D. These re-arrangements lead to qualitative changes in the force-distance profile when compared to the asymptotic quadrupole-quadrupole interaction. In line with the experimental results, the presence of the defects prevents coalescence of the colloidal particles in 2D, but not in 3D

  15. Actinide colloid generation in groundwater. Part 2

    Kim, J.I.

    1991-01-01

    The progress made in the investigation of actinide colloid generation in groundwater is summarized and discussed with particular examples relevant to an understanding of the migration behaviour of actinides in natural aquifer systems. The first part deals with the characterization of colloids: groundwater colloids, actinide real-colloids and actinide pseudocolloids. The second part concentrates on the generation processes and migration behaviour of actinide pseudo colloids, which are discussed with some notable experimental examples. Importance is stressed more on the chemical aspects of the actinide colloid generation in groundwater. This work is a contribution to the CEC Mirage II project, in particular the complexation and colloids research area

  16. Pharmacology of colloids and crystalloids.

    Griffel, M I; Kaufman, B S

    1992-04-01

    We have attempted to review body fluid distribution by compartments so that the reader understands the physiology of ICF and ECF, and the relationship between interstitial and intravascular fluids. Crystalloids such as NS and RL are distributed to the ECF, whereas colloids primarily remain intravascular for longer periods. Although effective, crystalloids tend to require larger volumes for infusion, and edema remains a problem. Colloids as a group are extremely effective volume expanders, but none is ideal. Albumin, hetastarch, dextran, and the less commonly used colloids each have significant toxicities that must be considered when using them. Intelligent choices can be made to optimize use of these fluids.

  17. Particles with changeable topology in nematic colloids

    Ravnik, Miha; Čopar, Simon; Žumer, Slobodan

    2015-01-01

    We show that nematic colloids can serve as a highly variable and controllable platform for studying inclusions with changeable topology and their effects on the surrounding ordering fields. We explore morphing of toroidal and knotted colloidal particles into effective spheres, distinctively changing their Euler characteristic and affecting the surrounding nematic field, including topological defect structures. With toroidal particles, the inner nematic defect eventually transitions from a wide loop to a point defect (a small loop). Trefoil particles become linked with two knotted defect loops, mutually forming a three component link, that upon tightening transform into a two-component particle-defect loop link. For more detailed topological analysis, Pontryagin-Thom surfaces are calculated and visualised, indicating an interesting cascade of defect rewirings caused by the shape morphing of the knotted particles. (paper)

  18. Driving dynamic colloidal assembly using eccentric self-propelled colloids

    Ma, Zhan; Lei, Qun-li; Ni, Ran

    2017-01-01

    Designing protocols to dynamically direct the self-assembly of colloidal particles has become an important direction in soft matter physics because of the promising applications in fabrication of dynamic responsive functional materials. Here using computer simulations, we found that in the mixture of passive colloids and eccentric self-propelled active particles, when the eccentricity and self-propulsion of active particles are high enough, the eccentric active particles can push passive coll...

  19. Examination of Laser Microprobe Vacuum Ultraviolet Ionization Mass Spectrometry with Application to Mapping Mars Returned Samples

    Burton, A. S.; Berger, E. L.; Locke, D. R.; Lewis, E. K.; Moore, J. F.

    2018-04-01

    Laser microprobe of surfaces utilizing a two laser setup whereby the desorption laser threshold is lowered below ionization, and the resulting neutral plume is examined using 157nm Vacuum Ultraviolet laser light for mass spec surface mapping.

  20. Laser microprobe for the study of noble gases and nitrogen in single ...

    R. Narasimhan (Krishtel eMaging) 1461 1996 Oct 15 13:05:22

    Planetary and Geosciences Division, Physical Research Laboratory, Ahmedabad 380 009, India. ∗e-mail: murty@prl.ernet.in. A laser microprobe capable of analysing nitrogen and noble gases in .... tion properties for light radiation, with some.

  1. Frost Heave in Colloidal Soils

    Peppin, Stephen; Majumdar, Apala; Style, Robert; Sander, Graham

    2011-01-01

    We develop a mathematical model of frost heave in colloidal soils. The theory accountsfor heave and consolidation while not requiring a frozen fringe assumption. Two solidificationregimes occur: a compaction regime in which the soil consolidates

  2. Contribution to the application of nuclear microprobe in geochemistry. Carbon and nitrogen microanalysis in glasses and minerals

    Mosbah, M.

    1988-01-01

    The morphological complexity of geological materials implies the use of microanalysis techniques utilization. Nuclear microprobe allows selective and no destructive light elements determination, through nuclear reactions. Nuclear microanalysis has been used to characterize carbon and nitrogen in volatile phase dissolved in magmatic samples. The application of some microanalysis techniques in geochemistry are discussed, nuclear microprobe theory and techniques are developed. Minerals, glasses and glassy inclusions are described, and more particularly, the interest of these investigations. Optimal conditions of carbon and nitrogen analysis ( 12 C(d.p) 13 C and 14 N(d,p) 15 N reaction respectively), as deuteron energy and observation angle are studied. A methodology has been established for this purpose. Several results are exposed: Punctual analysis, carbon concentration profile in depth surface scanning, surficial mapping in glassy inclusions. The carbon content interpretation in glassy inclusions measured conveniently for the first time agrees with data obtained through other techniques. In conclusion, degazing schedule improvements require more analysis. Perspective research axis are evocated [fr

  3. Micro-rheology on (polymer-grafted) colloids using optical tweezers

    Gutsche, C; Elmahdy, M M; Kegler, K; Semenov, I; Stangner, T; Otto, O; Ueberschaer, O; Kremer, F; Keyser, U F; Krueger, M; Rauscher, M; Weeber, R; Harting, J; Kim, Y W; Lobaskin, V; Netz, R R

    2011-01-01

    Optical tweezers are experimental tools with extraordinary resolution in positioning (± 1 nm) a micron-sized colloid and in the measurement of forces (± 50 fN) acting on it-without any mechanical contact. This enables one to carry out a multitude of novel experiments in nano- and microfluidics, of which the following will be presented in this review: (i) forces within single pairs of colloids in media of varying concentration and valency of the surrounding ionic solution, (ii) measurements of the electrophoretic mobility of single colloids in different solvents (concentration, valency of the ionic solution and pH), (iii) similar experiments as in (i) with DNA-grafted colloids, (iv) the nonlinear response of single DNA-grafted colloids in shear flow and (v) the drag force on single colloids pulled through a polymer solution. The experiments will be described in detail and their analysis discussed.

  4. Raman microprobe measurements of stress in ion implanted materials

    Nugent, K W; Prawer, S; Weiser, P S; Dooley, S P [Melbourne Univ., Parkville, VIC (Australia). School of Physics

    1994-12-31

    Raman microprobe measurements of ion implanted diamond and silicon have shown significant shifts in the Raman line due to stresses in the materials. The Raman line shifts to higher energy if the stress is compressive and to lower energy for tensile stress{sup 1}. The silicon sample was implanted in a 60 {mu}m square with 2.56 x 10{sup 17} ions per square centimeter of 2 MeV Helium. This led to the formation of raised squares with the top 370mm above the original surface. In Raman studies of silicon using visible light, the depth of penetration of the laser beam into the sample is much less than one micron. It was found that the Raman line is due to the silicon overlying the damage region. The diamond sample was implanted with 2 x 10{sup 15} ions per square centimeter of 2.8 MeV carbon. It was concluded that the Raman spectrum could provide information concerning both the magnitude and the direction of stress in an ion implanted sample. It was possible in some cases to determine whether the stress direction is parallel or perpendicular to the sample surface. 1 refs., 2 figs.

  5. Raman microprobe measurements of stress in ion implanted materials

    Nugent, K.W.; Prawer, S.; Weiser, P.S.; Dooley, S.P. [Melbourne Univ., Parkville, VIC (Australia). School of Physics

    1993-12-31

    Raman microprobe measurements of ion implanted diamond and silicon have shown significant shifts in the Raman line due to stresses in the materials. The Raman line shifts to higher energy if the stress is compressive and to lower energy for tensile stress{sup 1}. The silicon sample was implanted in a 60 {mu}m square with 2.56 x 10{sup 17} ions per square centimeter of 2 MeV Helium. This led to the formation of raised squares with the top 370mm above the original surface. In Raman studies of silicon using visible light, the depth of penetration of the laser beam into the sample is much less than one micron. It was found that the Raman line is due to the silicon overlying the damage region. The diamond sample was implanted with 2 x 10{sup 15} ions per square centimeter of 2.8 MeV carbon. It was concluded that the Raman spectrum could provide information concerning both the magnitude and the direction of stress in an ion implanted sample. It was possible in some cases to determine whether the stress direction is parallel or perpendicular to the sample surface. 1 refs., 2 figs.

  6. Characterization of colloids in groundwater

    Kim, J.I.; Buckau, G.; Klenze, R.

    1987-07-01

    Natural colloids in the Gorleben aquifer systems have been investigated as for their chemical composition, quantification and size distribution. Humic substances appear to be the major organic materials in these groundwaters, generating humic colloids which are analysed to be humic acid (and fulvic acid) loaded with a large number of trace heavy metal ions. These metal ions include natural homologues of actinides and some fission products in trivalent, tetravalent and hexavalent state. Concentrations of trivalent and tetravalent heavy metal ions are linearly correlated with the dissolved organic carbon (DDC) concentration in different groundwaters. The DOC is found to be present as humic colloids. The Am 3+ ions introduced in such a groundwater readily undergo the generation of its pseudocolloids through sorption or ion exchange reactions with humic colloids. The chemical behaviour of Am(III), being similar to the trivalent metal ions, e.g. Fe 3+ , REE etc. found in natural colloids, has been investigated by laser induced photoacoustic spectroscopy (LPAS). Groundwaters from Ispra, Markham Clinton and Felslabor Grimsel. Bidistilled water and one of Gorleben groundwaters, Gohy 1011, are taken for the purpose of comparison. This groundwater contains the least amount of natural colloids of all Gorleben groundwaters hitherto investigated. An indirect quantification is made by comparison of the LPAS results with experiment from Latex solution. (orig./IRB)

  7. Characterisation of Inorganic Pigments Used by Selected Painters by Using Ion Microprobe and Other Complementary Techniques

    Fazinic, S.; Pastuovic, Z.; Jaksic, M.; Kusijanovic, K.; Mudronja, D.; Braun, M.; Desnica, V.

    2011-01-01

    The aim of the presentation is to show results of the collaboration between the Croatian Conservation Institute (CCI) and the Laboratory for Ion Beam Interactions of the Rudjer Boskovic Institute (RBI) established within the present CRP. CCI is the central Croatian institution for conservation and restoration of cultural heritage objects. Prior to restoration/conservation CCI performs scientific analysis of an object, primarily to enable selection of the best strategy for its restoration/conservation. In many occasions such analysis is also helpful to resolve issues such as clarification of authenticity and/or authorship of an object. CCI has its analytical laboratory which is fully dedicated to the analysis of cultural heritage and art objects. CCI analytical laboratory is equipped with various microscopy techniques, photography methods, portable X-ray Fluorescence Spectrometer (XRF) and X-ray radiography instrumentation. Access to complementary microanalytical techniques like Raman Spectroscopy or Ion Beam Analytical (IBA) techniques is provided through already long and successful collaboration with RBI. The RBI Laboratory for Ion Beam Interactions provides complementary analysis of layered microsamples by using IBA techniques, such as Particle Induced X-ray Emission (PIXE) and Rutherford Back-scattering (RBS), and for the miniature samples by using ion microprobe. (author)

  8. Colloidal silver solutions with antimicrobial properties

    Petica, A.; Gavriliu, S.; Lungu, M.; Buruntea, N.; Panzaru, C.

    2008-01-01

    Some colloidal silver solutions involving the electrochemical technique with 'sacrificial anode method and different stabilizers and co-stabilizers' have been prepared. A constant current pulse generator with stirrer at different working times has been used. To achieve stable colloidal silver solutions, a mix of different tensioactive agents namely [poly (N-vinylpyrrolidone)], Na-naphthalene sulphonate, Na-lauryl sulfate and Na-dodecyl sulphonate were tested. The effects of these various mixes of polymer and ionic surfactants upon the Ag concentration and UV-vis spectra of silver nanoparticles were determined by spectrophotometer techniques. The nanoparticles sizes have been analyzed through dynamic light scattering technique and the silver nanoparticle morphology has been evidenced by transmission electron microscopy (TEM). Micobiological analysis has been made by determining minimal inhibitorial concentration upon the following germs: Staphylococcus aureus (ATCC) (Gram-positive cocci), Pseudomonas aeruginosa (ATTC), Escherichia coli (ATCC) and Acinetobacter spp. (Gram-negative coccobacillus). To evaluate the antifungal effect, the antibiogram method involving various tests using a fungi mix of Aspergillus, Penicillium and Trichoderma species has been used. The presented method allows obtaining of some stable colloidal solutions containing up to 35 ppm of Ag with very good antimicrobial and antifungal properties

  9. Colloidal silver solutions with antimicrobial properties

    Petica, A. [INCDIE ICPE-Advanced Research, Bucharest (Romania)], E-mail: petica@icpe-ca.ro; Gavriliu, S.; Lungu, M.; Buruntea, N. [INCDIE ICPE-Advanced Research, Bucharest (Romania); Panzaru, C. [Institute of Medicine and Pharmacy, Iassy (Romania)

    2008-08-25

    Some colloidal silver solutions involving the electrochemical technique with 'sacrificial anode method and different stabilizers and co-stabilizers' have been prepared. A constant current pulse generator with stirrer at different working times has been used. To achieve stable colloidal silver solutions, a mix of different tensioactive agents namely [poly (N-vinylpyrrolidone)], Na-naphthalene sulphonate, Na-lauryl sulfate and Na-dodecyl sulphonate were tested. The effects of these various mixes of polymer and ionic surfactants upon the Ag concentration and UV-vis spectra of silver nanoparticles were determined by spectrophotometer techniques. The nanoparticles sizes have been analyzed through dynamic light scattering technique and the silver nanoparticle morphology has been evidenced by transmission electron microscopy (TEM). Micobiological analysis has been made by determining minimal inhibitorial concentration upon the following germs: Staphylococcus aureus (ATCC) (Gram-positive cocci), Pseudomonas aeruginosa (ATTC), Escherichia coli (ATCC) and Acinetobacter spp. (Gram-negative coccobacillus). To evaluate the antifungal effect, the antibiogram method involving various tests using a fungi mix of Aspergillus, Penicillium and Trichoderma species has been used. The presented method allows obtaining of some stable colloidal solutions containing up to 35 ppm of Ag with very good antimicrobial and antifungal properties.

  10. 7th international conference on Nuclear microprobe technology and applications; 7. conference internationale sur la technologie et les applications des microsondes nucleaires

    NONE

    2000-07-01

    This colloquium gives an up-to-date report on the continuously advancing applications and development of microbeam technology. It presents abstracts and oral contributions in the following domains: microprobes facilities, analysis techniques, imaging techniques, micro-ion beam modification of materials, microelectronics, applications in Material Sciences in Biology in Medicine in earth and planetary Sciences in environment in art in archaeology, alternative techniques. (A.L.B.)

  11. Colloid remediation in groundwater by polyelectrolyte capture

    Nuttall, H.E.; Rao, S.; Jain, R.

    1992-01-01

    This paper describes an ongoing study to characterize groundwater colloids, to understand the geochemical factors affecting colloid transport in groundwater, and to develop an in-situ colloid remediation process. The colloids and suspended particulate matter used in this study were collected from a perched aquifer site that has radiation levels several hundred times the natural background and where previous researchers have measured and reported the presence of radiocolloids containing plutonium and americium. At this site, radionuclides have spread over several kilometers. Inorganic colloids collected from water samples are characterized with respect to concentration, mineralogy, size distribution, electrophoretic mobility (zeta potential), and radioactivity levels. Presented are the methods used to investigate the physiochemical factors affecting colloid transport and the preliminary analytical results. Included below are a description of a colloid transport model and the corresponding computational code, water analyses, characterization of the inorganic colloids, and a conceptual description of a process for in-situ colloid remediation using the phenomenon of polyelectrolyte capture

  12. The kinetics of phagocytosis of 198Au colloids ''in vitro''

    Astorri, N.L.; Bergoc, R.M.; Bianchin, A.M.; Caro, R.A.; Ihlo, J.E.; Rivera, E.S.

    1982-01-01

    The kinetics of the phagocytosis of 198-Au colloids by macrophages ''in vitro'' was studied by incubating during 5 hours phagocytic cells from the liver and the spleen of Wistar rats with colloidal radiogold particles, in the presence of an adequate culture medium (TC-199 with 10 per cent of Bovine Fetal Serum). In each experiment, the number of colloidal gold particles offered to each phatocytic cell, (Au) 0 and the mean rate of phagocytosis v, were calculated. The latter value was determined by measuring the radioactivity incorporated into the phagocytic cells during the incubation; it was expressed as the number of phagocytized colloidal gold particles per cell per minute. The values of log v = f [log (Au) 0 ] were plotted. The Lineweaver-Burk analysis of the results demonstrates that the kinetics of the phagocytosis of colloidal radiogold particles ''in vitro'' follows a model similar to Michaelis-Menten equations for enzyme reactions. The values of the substratum constant Ks and maximun velocity Vm were obtained by the regression analysis of the 1/v vs. 1/(Au) 0 graph. Vm was equal to 9.44 x 10 and 1.63 x 10 phagocytized colloidal gold particles per cell per minute for liver and spleen macrophages, respectively. Ks was equal to 6.01 x 10 9 and 8.02 x 10 8 colloidal gold particles per cell for liver and spleen macrophages, respectively. The significance of these differences is discussed and attributed mainly to a change of the specific engulfment rate constant. (author) [es

  13. Wave oscillations in colloid oxyhydrates wave oscillations in colloid oxyhydrates

    Sucharev, Yuri I

    2010-01-01

    The importance of coherent chemistry, that is, the chemistry of periodic oscillatory processes, is increasing at a rapid rate in specific chemical disciplines. While being perfectly understood and highly developed in the fields of physical chemistry, chemical physics and biological chemistry, the periodic developmental paradigm of processes and phenomena still remains poorly developed and misunderstood in classical inorganic chemistry and related branches, such as colloid chemistry. The probability is that we miss subtle colloid chemical phenomena that could be of utmost importance if taken into consideration when catalysis or adsorption is involved. The author here reveals all of the astonishing vistas that periodic wave paradigms open up to researchers in certain colloid chemical systems, and will doubtless stimulate researchers to look at them in a new light.Review from Book News Inc.: Coherent chemistry, the chemistry of periodical oscillatory processes, is well established in physical chemistry, chemical...

  14. Sampling and characterisation of groundwater colloids in ONKALO at Olkiluoto, Finland, 2011

    Takala, M.; Ojala, S.; Jarvinen, E.; Manninen, P. [Ramboll Finland Oy, Espoo (Finland)

    2012-11-15

    The purpose of this study was to estimate the concentration of colloids and composition of the colloid phase on the basis of the water chemistry results of filtered and unfiltered water samples and to compare the results with the previous ones. The water samples were collected from groundwater stations ONK-PVA1 and ONK-PVA3 in October 2011. The colloid concentrations were determined from scanning electron microscopy (SEM) micrographs taken from the filters. The change in the water chemistry due to filtration was also analysed. The decrease of element concentrations due to filtration would possibly reflect the composition of the colloid phase. Because the concentration of the colloids is very low, two parallel water samples were analysed five times with an Inductively Coupled Plasma - Mass Spectrometry (ICP-MS) analyser so that the chemical differences between the filtered and unfiltered water could be evaluated. The colloid concentration in ONK-PVA1, determined by the single particle analysis of SEM micrographs, was 6 {mu}g/l while the colloid concentration in ONK-PVA3 was 7 {mu}g/l. The colloid phase composition could not be reliably determined due to the low colloid concentration. (orig.)

  15. Sampling and characterisation of groundwater colloids in ONKALO at Olkiluoto, Finland 2009-2010

    Jaervinen, E.; Manninen, P.; Takala, M.; Vilhunen, S.

    2011-04-01

    The purpose of this study was to estimate the concentration of colloids and composition of the colloid phase on the basis of the water chemistry results of filtered and unfiltered water samples and to compare the results with the previous ones. The water samples were collected from groundwater stations ONK-PVA1 in December 2009 and ONKPVA5 in June 2010. The colloid concentrations were determined from scanning electron microscopy (SEM) micrographs taken from the filters. The change in the water chemistry due to filtration was also analysed. The decrease of element concentrations due to filtration would possibly reflect the composition of the colloid phase. Because the concentration of the colloids is very low, three parallel water samples were analysed three times with an Inductively Coupled Plasma - Mass Spectrometry (ICP-MS) analyser so that the chemical differences between the filtered and unfiltered water could be evaluated. The colloid concentration in ONK-PVA1, determined by the single particle analysis of SEM micrographs, was 0.5 μg/l while the colloid concentration in ONK-PVA5 was 0.15 μg/l. The colloid phase composition could not be reliably determined due to the low colloid concentration. (orig.)

  16. A study of aluminium-exposed fish using a scanning proton microprobe

    Cholewa, M; Legge, G L.F. [Melbourne Univ., Parkville, VIC (Australia). School of Physics; Eeckhaoudt, S; Van Grieken, R [Universitaire Instelling Antwerpen, Antwerp (Belgium)

    1994-12-31

    A major problem has arisen in Europe with the depopulation of fresh water fish in lakes and streams collecting acid rain. The sensitivity to acidification is species specific and appears to be associated with metal levels. The Scanning Proton Microprobe (SPMP) at the Micro Analytical Research Centre of the University of Melbourne was used to study the subcellular distribution of aluminium and other elements in the gills of fish exposed to acidified water with elevated Al-levels. Experiments were performed on thin sections taken from fish exposed to media with different pH and aluminium concentration. Aluminium was found on the surface of the gill lamellae, but also inside the tissue. Bulk analysis of the gills showed much higher concentrations in the aluminium-exposed fish, compared to the control ones, but no information regarding the actual accumulation sites can be inferred. Extensive study of damage done to the sample by intense proton beams during elemental analysis was performed with scanning transmission ion microscopy. 3 refs., 3 figs.

  17. A study of aluminium-exposed fish using a scanning proton microprobe

    Cholewa, M.; Legge, G.L.F. [Melbourne Univ., Parkville, VIC (Australia). School of Physics; Eeckhaoudt, S.; Van Grieken, R. [Universitaire Instelling Antwerpen, Antwerp (Belgium)

    1993-12-31

    A major problem has arisen in Europe with the depopulation of fresh water fish in lakes and streams collecting acid rain. The sensitivity to acidification is species specific and appears to be associated with metal levels. The Scanning Proton Microprobe (SPMP) at the Micro Analytical Research Centre of the University of Melbourne was used to study the subcellular distribution of aluminium and other elements in the gills of fish exposed to acidified water with elevated Al-levels. Experiments were performed on thin sections taken from fish exposed to media with different pH and aluminium concentration. Aluminium was found on the surface of the gill lamellae, but also inside the tissue. Bulk analysis of the gills showed much higher concentrations in the aluminium-exposed fish, compared to the control ones, but no information regarding the actual accumulation sites can be inferred. Extensive study of damage done to the sample by intense proton beams during elemental analysis was performed with scanning transmission ion microscopy. 3 refs., 3 figs.

  18. Practical aspects of quantitative laser Raman microprobe spectroscopy for the study of fluid inclusions

    Pasteris, J.D.; Wopenka, B.; Seitz, J.C.

    1988-01-01

    This paper is addressed to both geologists who use laser Raman microprobe (LRM) spectroscopy to analyze fluid inclusions and to those who want to evaluate analyses done by this technique. Emphasis is on how to obtain quantitative analyses of fluid inclusions. The authors discuss the basic method of fluid inclusion analysis by LRM spectroscopy and the levels of accuracy and precision attainable with this technique. They evaluate which kinds of fluid inclusions and host mineral matrices will yield the most reliable compositional data. Necessary sample preparations, detection limits, problems with fluorescence, dependence of Raman scattering efficiencies on density, and many other questions asked at the workshop on Raman spectroscopy during the 1987 ACROFI meeting also are addressed. The complementary nature, advantages, and disadvantages of both LRM spectroscopy and microthermometry, the two techniques most frequently used for the analysis of individual fluid inclusions, are emphasized. Some discussions are intended to held LRM users calibrate, and evaluate the optical characteristics of, their particular instruments. It is hoped that this paper will further LRM users in finding a common ground on which to discuss the differences and similarities among different LRM instruments, and that it will encourage a future consensus on efficient means of calibration and on interlaboratory standards

  19. A study of aluminium-exposed fish using a scanning proton microprobe

    Cholewa, M.; Legge, G.L.F.

    1993-01-01

    A major problem has arisen in Europe with the depopulation of fresh water fish in lakes and streams collecting acid rain. The sensitivity to acidification is species specific and appears to be associated with metal levels. The Scanning Proton Microprobe (SPMP) at the Micro Analytical Research Centre of the University of Melbourne was used to study the subcellular distribution of aluminium and other elements in the gills of fish exposed to acidified water with elevated Al-levels. Experiments were performed on thin sections taken from fish exposed to media with different pH and aluminium concentration. Aluminium was found on the surface of the gill lamellae, but also inside the tissue. Bulk analysis of the gills showed much higher concentrations in the aluminium-exposed fish, compared to the control ones, but no information regarding the actual accumulation sites can be inferred. Extensive study of damage done to the sample by intense proton beams during elemental analysis was performed with scanning transmission ion microscopy. 3 refs., 3 figs

  20. Bentonite as a colloid source in groundwaters at Olkiluoto

    Vuorinen, U.; Hirvonen, H.

    2005-02-01

    In this work bentonite was studied as a potential source of colloids in Olkiluoto groundwaters. Samples were collected at two groundwater stations, PVA1 at 37.5 m dept and PVA3 at 95.6 m depth, in the VLJ-tunnel. The deeper groundwater at PVA3 was more saline (2.6g/L of Cl-) than the shallow at PVA1 (0.8g/L of Cl-). A bentonite source had been assembled at each groundwater station so that two sample lines were available for water samples; one for collecting a sample before and the other for collecting a sample after interaction with bentonite. Before starting the actual colloid sampling groundwaters from both sample lines at both stations were analysed. Only minor alterations, mostly within the uncertainty limits of the analysis methods, were brought about in the water chemistries after interaction with the bentonite sources. The only clear changes were seen in the concentration of iron which decreased after interaction with bentonite in the groundwaters at both stations. After groundwater sampling the actual colloid sampling was performed. The water samples were collected and treated inside a movable nitrogen filled glove-box. The samples could be collected from each sampling line directly in the glove-box via two quick-couplings that had been assembled on the front face of the box. The sample lines had been assembled with 0.45 μm filters before entering the glove-box, because only colloids smaller than 0.45 μm were of interest, as they are not prone to sedimentation in slow groundwater flows and therefore could act as potential radionuclide carriers. Colloid samples were collected and treated similarly from both sampling lines at both groundwater stations. For estimating the colloid content the groundwater samples were filtered with centrifugal ultrafiltration tubes of different cut-off values (0.3 μm, 300kD and 10kD). The ultrafiltrations produced the colloid-containing concentrate fractions and the soluble substances-containing filtrate fractions. In

  1. Spectroscopic studies on colloid-borne uranium

    Ulrich, K.U.; Weiss, S.; Foerstendorf, H.; Brendler, V.; Zaenker, H.; Rossberg, A.; Scheinost, A.C.

    2005-01-01

    Full text of publication follows: Information on molecular speciation provides a basis for the reliable assessment of actinide migration in the environment. We use several methods for the separation of colloids from liquids (e.g. ultracentrifugation, ultrafiltration) in combination with spectroscopic techniques (EXAFS, ATR-FTIR, Moessbauer) and modeling of surface complexation reactions. This enables us to investigate the speciation of colloid-borne uranium in waters occurring in or escaping from abandoned uranium mines during the remediation process. Mine flooding was simulated on a 100 L scale by mixing acid mine water of elevated U concentration with oxic, near-neutral groundwater until pH ∼ 5.5 was reached. The freshly formed colloids adsorbed 95% of the total uranium and consisted mainly of 2-line ferri-hydrite (Fh) besides traces of aluminum, sulfur, silica, and carbon compounds. EXAFS analysis at the U-LIII absorption edge suggested a bidentate surface complex of UO 2 2+ on FeO 6 octahedra, but two minor backscattering contributions in close vicinity to the absorber remained unexplained. Since only Al could be excluded as backscattering atom, we studied U sorption on Fh at pH 5.5 in presence and in absence of sulfate, silicate, and atmospheric CO 2 to clarify the bond structure. EXAFS showed the unknown backscattering contributions in all the sorption samples regardless of the presence or absence of the tested components. Contrary to structural models proposed in the literature, bi-dentately complexed carbonate ligands do not explain our experimental EXAFS data. But ATR-IR spectra showed that U-carbonato complexes must be involved in the sorption of uranyl on Fh. These results are not contradictory if the carbonate ligands were bound mono-dentately. Nevertheless, carbon cannot act as backscattering atom in carbonate-free samples prepared in N 2 atmosphere. We propose a new structural model including exclusively Fe, H, and O atoms in which the bi

  2. The radiation chemistry of colloids

    Sellers, R.M.

    1976-08-01

    One of the most important problems associated with water cooled reactors is the accumulation on the pipework of radio-active deposits. These are formed from corrosion products which become activated during their passage through the reactor core. The first step of the activation process involves the deposition of the corrosion products, which are present as either colloidal or particulate matter, onto surfaces in the reactor core, i.e. within the radiation zone. A review of the literature on the effect of radiation on colloids is presented. Particular emphasis is given to the dependence of colloidal parameters such as particle size, turbidity and electrophoretic mobility on radiation dose. Most of the data available is of a qualitative nature only. Evidence is presented that colloids of iron are affected (in some cases precipitated) by radiation, and it is suggested that this process plays a part in the deposition of corrosion products in nuclear reactor cores. The bulk of the information available can be rationalized in terms of the radiation chemistry of aqueous solutions, and the interaction of the radicals produced with the atoms or molecules at the surface of the colloidal particles. This approach is very successful in explaining the variation of the mean particle size of monodisperse sulphur hydrosols with dose, for which quantitative experimental data are available. (author)

  3. On the nature of fibres grown from nanodiamond colloids

    Batsanov, Stepan S., E-mail: batsanov@mail.ru [National Research Institute of Physical-Technical Measurements, Moscow Region (Russian Federation); Guriev, Dmitry L.; Gavrilkin, Sergey M. [National Research Institute of Physical-Technical Measurements, Moscow Region (Russian Federation); Hamilton, Katherine A.; Lindsey, Keith [School of Biological and Biomedical Sciences, Durham University, Durham (United Kingdom); Mendis, Budhika G. [Physics Department, Durham University, Durham (United Kingdom); Riggs, Helen J.; Batsanov, Andrei S. [Chemistry Department, Durham University, Durham (United Kingdom)

    2016-04-15

    Contrary to earlier assumptions, the fibres spontaneously forming in aqueous colloids of detonation-produced nanodiamond (ND), do not consist purely of ND particles but are agglomerates of the latter with water and/or soft matter of biological (probably fungal) origin, as shown by elemental analysis, IR and Raman spectroscopy, X-ray diffraction, optical refractometry, optical and electron (TEM and ESEM)microscopy, as well as biological staining tests. - Graphical abstract: Fibres spontaneously formed in water colloids of nanodiamond, consist of diamond nanoparticles dispersed in bioorganic matter. - Highlights: • Entangled fibres slowly grow in dilute (∼0.1%) colloids of nanodiamond in water. • Refractive index (∼1.56), electron microscopy and CHN analysis indicate nanodiamond dispersed in organic matter. • Explanation: nanodiamond grains help the growth of fungi which assemble them.

  4. On the nature of fibres grown from nanodiamond colloids

    Batsanov, Stepan S.; Guriev, Dmitry L.; Gavrilkin, Sergey M.; Hamilton, Katherine A.; Lindsey, Keith; Mendis, Budhika G.; Riggs, Helen J.; Batsanov, Andrei S.

    2016-01-01

    Contrary to earlier assumptions, the fibres spontaneously forming in aqueous colloids of detonation-produced nanodiamond (ND), do not consist purely of ND particles but are agglomerates of the latter with water and/or soft matter of biological (probably fungal) origin, as shown by elemental analysis, IR and Raman spectroscopy, X-ray diffraction, optical refractometry, optical and electron (TEM and ESEM)microscopy, as well as biological staining tests. - Graphical abstract: Fibres spontaneously formed in water colloids of nanodiamond, consist of diamond nanoparticles dispersed in bioorganic matter. - Highlights: • Entangled fibres slowly grow in dilute (∼0.1%) colloids of nanodiamond in water. • Refractive index (∼1.56), electron microscopy and CHN analysis indicate nanodiamond dispersed in organic matter. • Explanation: nanodiamond grains help the growth of fungi which assemble them.

  5. Crack formation and prevention in colloidal drops

    Kim, Jin Young; Cho, Kun; Ryu, Seul-A.; Kim, So Youn; Weon, Byung Mook

    2015-08-01

    Crack formation is a frequent result of residual stress release from colloidal films made by the evaporation of colloidal droplets containing nanoparticles. Crack prevention is a significant task in industrial applications such as painting and inkjet printing with colloidal nanoparticles. Here, we illustrate how colloidal drops evaporate and how crack generation is dependent on the particle size and initial volume fraction, through direct visualization of the individual colloids with confocal laser microscopy. To prevent crack formation, we suggest use of a versatile method to control the colloid-polymer interactions by mixing a nonadsorbing polymer with the colloidal suspension, which is known to drive gelation of the particles with short-range attraction. Gelation-driven crack prevention is a feasible and simple method to obtain crack-free, uniform coatings through drying-mediated assembly of colloidal nanoparticles.

  6. Colloid Thrusters, Physics, Fabrication and Performance

    Martinez-Sanchez, Manuel; Akinwande, Akintunde I

    2005-01-01

    ... discovered pure ionic mode, the microfabrication in Silicon of two types of arrays of colloid or electrospray emitters, and the development of a quantitative theory for the colloidal regime (no ions...

  7. Entropy favours open colloidal lattices

    Mao, Xiaoming; Chen, Qian; Granick, Steve

    2013-03-01

    Burgeoning experimental and simulation activity seeks to understand the existence of self-assembled colloidal structures that are not close-packed. Here we describe an analytical theory based on lattice dynamics and supported by experiments that reveals the fundamental role entropy can play in stabilizing open lattices. The entropy we consider is associated with the rotational and vibrational modes unique to colloids interacting through extended attractive patches. The theory makes predictions of the implied temperature, pressure and patch-size dependence of the phase diagram of open and close-packed structures. More generally, it provides guidance for the conditions at which targeted patchy colloidal assemblies in two and three dimensions are stable, thus overcoming the difficulty in exploring by experiment or simulation the full range of conceivable parameters.

  8. Colloid Release from Soil Aggregates

    Vendelboe, Anders Lindblad; Møldrup, Per; Schjønning, Per

    2012-01-01

    The content of water-dispersible colloids (WDC) has a major impact on soil functions and structural stability. In addition, the presence of mobile colloids may increase the risk of colloid-facilitated transport of strongly sorbing environmental contaminants. The WDC content was measured in 39 soils......, using laser diffraction, by agitating the samples using a wet-dispersion unit. This approach eliminated the need for long sedimentation times required by the more classical end-over-end shaking approach and provided information about the time-dependent release of WDC. The total clay content of the soils...... ranged from 0.1 to 0.44 kg kg−1. The WDC content was measured on air-dry and moist 1- to 2-mm aggregates. The WDC content at a reference time was highly correlated to the total clay content (r > 0.91, P soils. Only for two sites was the WDC content correlated to the content of clay...

  9. Analysis of humic colloid borne trace elements by flow field-flow fractionation, gel permeation chromatography and icp-mass spectrometry

    Ngo, Manh Thang; Beck, H.P; Geckeis, H.; Kim, J.I.

    1999-01-01

    Groundwater samples containing aquatic humic substances are analyzed by flow field- flow fractionation (FFFF) and gel permeation chromatography (GPC). Natural concentrations of U, Th and rare earth elements (REE) in a size-fractionated groundwater sample are analyzed by on-line coupling of inductively coupled plasma-mass spectrometry (ICP-MS) to either FFFF or GPC. The uranium, thorium, and REE are found to be quantitatively attached to colloidal species in the investigated groundwater sample. Their distribution in different colloid size fractions, however, is quite heterogeneous. Both, FFFF and GPC reveal that Th and REE are preferentially located in the size fraction > 50 kDalton. U is also attached to low molecular weight humic acid, similar to Fe and Al. This finding could be qualitatively reproduced by sequential ultrafiltration. The results are interpreted in terms of different binding mechanisms for the individual elements in the heterogeneous humic macromolecules. The inclusion of actinides into larger aggregates of aquatic humic acid might explain the considerable kinetic hindrance of actinide-humic acid dissociation reactions described in the literature. (authors)

  10. Raman and luminescence spectroscopy of zirconium oxide with the use of the MOLE microprobe

    Doyle, T.E.; Alvarez, J.L.

    1984-01-01

    Raman and luminescence spectroscopy with the use of the MOLE microprobe has been used to characterize ZrO 2 originating from oxidized fuel-rod cladding in nuclear accidents. Micro-Raman analysis of samples from Three Mile Island Unit 2 and the Power Burst Facility identified tetragonal and cubic ZrO 2 . The tetragonal and cubic phases are high-temperature polymorphs of ZrO 2 and provide information about temperatures and hydrogen formation in the TMI-2 core. The data suggest that the tetragonal ZrO 2 in TMI-2 samples was stabilized by a crystallite size effect, whereas cubic ZrO 2 in PBF debris samples was stabilized by impurities. Luminescence was used to differentiate yttria-stabilized ZrO 2 ceramics and oxidized fuel-rod cladding in PBF debris samples. The ZrO 2 ceramics produced strong, sharp luminescence peaks which indicated the presence of titanium and yttria in the ZrO 2 . Oxidized fuel-rod cladding displayed no luminescence

  11. Treatment of dentin with stannous fluoride - SEM and electron microprobe study

    Ellingsen, J.E.; Roella, G.

    1987-01-01

    The effect of SnF 2 -treatment of dentin surfaces was investigated by means of scanning electron microscopy (SEM) and electron microprobe analysis. Human dentin was treated with aqueous SnF 2 solutions of concentrations varying from 1 to 10%. The treatment periods lasted for 1, 5, 10 or 60 min. Both tin and fluoride were identified on the surfaces. The concentration varied depending on the extensiveness of the treatment. Immersion in 1 M KOH for 15 h removed both tin and fluoride from the surfaces. This reaction was not observed after immersion in H 2 O for the same time period. Examination of the SnF 2 -treated dentin surfaces showed a dense layer of globular particles and in addition some larger particles. The dentinal tubules were totally covered even after the treatment with the lowest concentration of SnF 2 . Deposition of tin- and fluoride-containing globules on dentin surfaces may be of clinical interest. This layer may have importance both for the caries resistance of dentin and for hypersensitivity reactions. (author)

  12. Nuclear microprobe studies of elemental distributions in dormant seeds of Burkea africana

    Witkowski, E. T. F.; Weiersbye-Witkowski, I. M.; Przybyłowicz, W. J.; Mesjasz-Przybyłowicz, J.

    1997-07-01

    Seed nutrient stores are vital post-germination for the establishment of seedlings in harsh and unpredictable environments. Plants of nutrient-poor environments allocate a substantial proportion of total acquired nutrients to reproduction (i.e. seeds). We propose that differential allocation of mineral resources to specific seed tissues is an indication of a species germination and establishment strategy. Burkea africana Hook is a leguminous tree typical of broad-leaved nutrient-poor savannas in southern Africa. Elemental distributions in dormant B. africana seed structures were obtained using the true elemental imaging system (Dynamic Analysis) of the NAC Van de Graaff nuclear microprobe. Raster scans of 3.0 MeV protons were complemented by simultaneous BS and PIXE point analyses. Mineral nutrient concentrations varied greatly between seed tissues. Elevated levels of metals known to play an important role as plant enzyme co-factors were found in the seed lens and embryonic axis. Distributions of most of these metals (Ca, Mn, Fe and Zn, but not K or Cu) were positively correlated with embryonic P distribution, and probably represent phytin deposits. The distribution of metals within seed structures is 'patchy' due to their complexation with P as electron-dense globoid phytin crystals, which constrains the interpretation of PIXE point analyses.

  13. Using Synchrotron X-ray Fluorescence Microprobes in the Study of Metal Homeostasis in Plants

    Punshon, T.; Guerinot, M.; Lanzirotti, A.

    2009-01-01

    Background and Aims: This Botanical Briefing reviews the application of synchrotron X-ray fluorescence (SXRF) microprobes to the plant sciences; how the technique has expanded our knowledge of metal(loid) homeostasis, and how it can be used in the future. Scope: The use of SXRF microspectroscopy and microtomography in research on metal homeostasis in plants is reviewed. The potential use of SXRF as part of the ionomics toolbox, where it is able to provide fundamental information on the way that plants control metal homeostasis, is recommended. Conclusions: SXRF is one of the few techniques capable of providing spatially resolved in-vivo metal abundance data on a sub-micrometre scale, without the need for chemical fixation, coating, drying or even sectioning of samples. This gives researchers the ability to uncover mechanisms of plant metal homeostasis that can potentially be obscured by the artefacts of sample preparation. Further, new generation synchrotrons with smaller beam sizes and more sensitive detection systems will allow for the imaging of metal distribution within single living plant cells. Even greater advances in our understanding of metal homeostasis in plants can be gained by overcoming some of the practical boundaries that exist in the use of SXRF analysis.

  14. Development of an external beam nuclear microprobe on the Aglae facility of the Louvre museum

    Calligaro, T.; Dran, J.-C. E-mail: dran@culture.fr; Ioannidou, E.; Moignard, B.; Pichon, L.; Salomon, J

    2000-03-01

    The external beam line of our facility has been recently equipped with the focusing system previously mounted on a classical nuclear microprobe. When using a 0.1 {mu}m thick Si{sub 3}N{sub 4} foil for the exit window and flowing helium on the sample under analysis, a beam spot as small as 10 {mu}m is attainable at a distance of 3 mm from the window. Elemental micromapping is performed by mechanical scanning. An electronic device has been designed which allows XY scanning by moving the sample under the beam by steps down to 0.1 {mu}m. Beam monitoring is carried out by means of the weak X-ray signal emitted by the exit foil and detected by a specially designed Si(Li) detector cooled by Peltier effect. The characteristics of external beams of protons and alpha particles are evaluated by means of resonance scanning and elemental mapping of a grid. An example of application is presented, dealing with elemental micro-mapping of inclusions in gemstones.

  15. Microprobe PIXE study of Ni–Ge interactions in lateral diffusion couples

    Chilukusha, D. [Department of Physics, University of Zambia, P.O. Box 32379, Lusaka 10101 (Zambia); Pineda-Vargas, C.A. [iThemba LABS, National Research Foundation, P.O. Box 722, Somerset West 7129 (South Africa); Faculty of Health & Wellness Sciences, CPUT, Bellville (South Africa); Nemutudi, R. [iThemba LABS, National Research Foundation, P.O. Box 722, Somerset West 7129 (South Africa); Habanyama, A. [Department of Physics, Copperbelt University, P.O. Box 21692, Jambo Drive, Riverside, Kitwe 10101 (Zambia); Comrie, C.M. [iThemba LABS, National Research Foundation, P.O. Box 722, Somerset West 7129 (South Africa)

    2015-11-15

    Rutherford backscattering spectrometry on the nuclear microprobe (μRBS) is often used in studies of lateral diffusion couples. RBS requires that the positions of the interacting species on the periodic table are not too close in terms of atomic number and therefore do not produce excessive RBS peak overlap. In order to satisfactorily characterize systems that have atomic numbers which are close, it is necessary to find techniques which can complement μRBS. The aim of this study was to determine the extent to which particle induced X-ray emission (PIXE) could be applied in the lateral diffusion couple study of a system with relatively close atomic numbers. This was with a view that it may eventually be adopted to study systems where the atomic numbers are too close for RBS analysis. The system studied here was the Ni–Ge binary system. Since RBS is an established technique for studying lateral diffusion couples, we used it as a standard for comparison. The PIXE results showed a maximum error of 12% with reference to the RBS standard. In order to achieve the most effective use of PIXE in lateral diffusion couple studies we recommend the use of the technique in such a way as to obtain depth information and the use of relatively thick sample layers.

  16. Colloidal phytosterols: synthesis, characterization and bioaccessibility

    Rossi, L.; Seijen ten Hoorn, J.W.M.; Melnikov, S.M.; Velikov, K.P.

    2010-01-01

    We demonstrate the synthesis of phytosterol colloidal particles using a simple food grade method based on antisolvent precipitation in the presence of a non-ionic surfactant. The resulting colloidal particles have a rod-like shape with some degree of crystallinity. The colloidal dispersions display

  17. Self-Assembly of Faceted Colloidal Particles

    Gantapara, A.P.

    2015-01-01

    A colloidal dispersion consists of insoluble microscopic particles that are suspended in a solvent. Typically, a colloid is a particle for which at least one of its dimension is within the size range of a nanometer to a micron. Due to collisions with much smaller solvent molecules, colloids perform

  18. Colloid formation during waste glass corrosion

    Mertz, C.J.; Buck, E.C.; Fortner, J.A.; Bates, J.K.

    1996-01-01

    The long-term behavior of nuclear waste glass in a geologic repository may require a technical consideration of the role of colloids in the release and transport of radionuclides. The neglect of colloidal properties in assessing the near- and far-field migration behavior of actinides may lead to significant underestimates and poor predictions of biosphere exposure from high-level waste (HLW) disposal. Existing data on colloid-facilitated transport suggests that radionuclide migration may be enhanced, but the importance of colloids is not adequately assessed. Indeed, the occurrence of radionuclide transport, attributed to colloidal species, has been reported at Mortandad Canyon, Los Alamos and at the Nevada Test Site; both unsaturated regions are similar to the proposed HLW repository at Yucca Mountain. Although some developments have been made on understanding the transport characteristics of colloids, the characterization of colloids generated from the corrosion of the waste form has been limited. Colloids are known to incorporate radionuclides either from hydrolysis of dissolved species (real colloids) or from adsorption of dissolved species onto existing groundwater colloids (pseudocolloids); however, these colloids may be considered secondary and solubility limited when compared to the colloids generated during glass alteration

  19. Bonding assembled colloids without loss of colloidal stability

    Vutukuri, H.R.; Stiefelhagen, J.C.P.; Vissers, T; Imhof, A.; van Blaaderen, A.

    2012-01-01

    In recent years the diversity of self-assembled colloidal structures has strongly increased, as it is fueled by a wide range of applications in materials science and also in soft condensed-matter physics.[1–4] Some potential applications include photonic bandgap (PBG) crystals, materials for

  20. Hybrid electrokinetics for separation, mixing, and concentration of colloidal particles

    Sin, Mandy L Y; Shimabukuro, Yusuke; Wong, Pak Kin

    2009-01-01

    The advent of nanotechnology has facilitated the preparation of colloidal particles with adjustable sizes and the control of their size-dependent properties. Physical manipulation, such as separation, mixing, and concentration, of these colloidal particles represents an essential step for fully utilizing their potential in a wide spectrum of nanotechnology applications. In this study, we investigate hybrid electrokinetics, the combination of dielectrophoresis and electrohydrodynamics, for active manipulation of colloidal particles ranging from nanometers to micrometers in size. A concentric electrode configuration, which is optimized for generating electrohydrodynamic flow, has been designed to elucidate the effectiveness of hybrid electrokinetics and define the operating regimes for different microfluidic operations. The results indicate that the relative importance of electrohydrodynamics increases with decreasing particle size as predicted by a scaling analysis and that electrohydrodynamics is pivotal for manipulating nanoscale particles. Using the concentric electrodes, we demonstrate separation, mixing, and concentration of colloidal particles by adjusting the relative strengths of different electrokinetic phenomena. The effectiveness of hybrid electrokinetics indicates its potential to serve as a generic technique for active manipulation of colloidal particles in various nanotechnology applications.

  1. Development of a new measurement method for fast breeder reactor fuel burnup using a shielded ion microprobe analyzer

    Mizuno, M.; Enokido, Y.; Itaki, T.; Kono, K.; Unno, I.; Yamanouchi, S.

    1985-01-01

    A new method of burnup measurement using a shielded ion microprobe analyzer (SIMA) has been developed. The method is based on the isotope analysis of uranium, plutonium, and fission products in irradiated mixed oxide fuel by means of secondary ion mass spectrometry (SIMS). Fourteen samples irradiated in the Japanese experimental fast reactor JOYO were examined. The maximum local burnup of JOYO MK-I core fuels was about5.1 at. %. The axial burnup distribution of the fuel pin was in good agreement with that of the sibling pin in the same subassembly, measured by surface ionization mass spectrometry, which requires the chemical separation of fission products and heavy metals. The new method facilitates the rapid and accurate measurement of fast breeder reactor fuel burnup without human radiation exposure during sample preparation and analysis

  2. Iron distribution in cancer cells following doxorubicin exposure using proton and X-ray synchrotron radiation microprobes

    Ortega, R.; Deves, G.; Bohic, S.; Simionovici, A.; Menez, B.; Bonnin-Mosbah, M.

    2001-01-01

    Chemical studies have shown that doxorubicin, a well-established anticancer agent, is a powerful iron chelator and the resultant iron-drug complex is an efficient catalyst of the conversion of hydrogen peroxide to the highly reactive hydroxyl radical. However, the intracellular complexation of doxorubicin with iron is still debated. Using nuclear microprobe analysis (NMPA), we previously observed in human ovarian cancer cells exposed to 20 μM iodo-doxorubicin (IDX) that iodine and iron cellular distributions were spatially correlated, suggesting a mechanism of intracellular iron chelation by the anthracycline compound. Because maximal plasma drug concentrations in patients are expected to be around 5 μM, NMPA and X-ray absorption near edge spectroscopy (XANES) experiments for iron speciation analysis were performed on cultured cells exposed to pharmacological doses of 2 μM IDX or doxorubicin

  3. A binomial modeling approach for upscaling colloid transport under unfavorable conditions: Emergent prediction of extended tailing

    Hilpert, Markus; Rasmuson, Anna; Johnson, William P.

    2017-07-01

    Colloid transport in saturated porous media is significantly influenced by colloidal interactions with grain surfaces. Near-surface fluid domain colloids experience relatively low fluid drag and relatively strong colloidal forces that slow their downgradient translation relative to colloids in bulk fluid. Near-surface fluid domain colloids may reenter into the bulk fluid via diffusion (nanoparticles) or expulsion at rear flow stagnation zones, they may immobilize (attach) via primary minimum interactions, or they may move along a grain-to-grain contact to the near-surface fluid domain of an adjacent grain. We introduce a simple model that accounts for all possible permutations of mass transfer within a dual pore and grain network. The primary phenomena thereby represented in the model are mass transfer of colloids between the bulk and near-surface fluid domains and immobilization. Colloid movement is described by a Markov chain, i.e., a sequence of trials in a 1-D network of unit cells, which contain a pore and a grain. Using combinatorial analysis, which utilizes the binomial coefficient, we derive the residence time distribution, i.e., an inventory of the discrete colloid travel times through the network and of their probabilities to occur. To parameterize the network model, we performed mechanistic pore-scale simulations in a single unit cell that determined the likelihoods and timescales associated with the above colloid mass transfer processes. We found that intergrain transport of colloids in the near-surface fluid domain can cause extended tailing, which has traditionally been attributed to hydrodynamic dispersion emanating from flow tortuosity of solute trajectories.

  4. Real-time observation of template-assisted colloidal aggregation and colloidal dispersion under an alternating electric field

    Chao-Rong, Li; Shu-Wen, Li; Jie, Mei; Qing, Xu; Ying-Ying, Zheng; Wen-Jun, Dong

    2011-01-01

    A fascinating colloid phenomenon was observed in a specially designed template-assisted cell under an alternating electrical field. Most colloidal particles experienced the processes of aggregation, dispersion and climbing up to the plateaus of the patterns pre-lithographed on the indium tin oxide glass as the frequency of the alternating electrical field increased. Two critical frequencies f crit1 ≈ 15 kHz and f crit2 ≈ 40 kHz, corresponding to the transitions of the colloid behaviour were observed. When f < 15 kHz, the particles were forced to aggregate along the grooves of the negative photoresist patterned template. When 15 kHz < f < 40 kHz, the particle clusters became unstable and most particles started to disperse and were blocked by the fringes of the negative photoresist patterns. As the frequency increased to above 40 kHz, the majority of particles started to climb up to the plateaus of the patterns. Furthermore, the dynamics analysis for the behaviour of the colloids was given and we found out that positive or negative dielectrophoresis force, electrohydrodynamic force, particle—particle interactions and Brownian motion change with the frequency of the alternating electric field. Thus, changes of the related forces affect or control the behaviour of the colloids. (interdisciplinary physics and related areas of science and technology)

  5. Capillary Assembly of Colloids: Interactions on Planar and Curved Interfaces

    Liu, Iris B.; Sharifi-Mood, Nima; Stebe, Kathleen J.

    2018-03-01

    In directed assembly, small building blocks are assembled into an organized structure under the influence of guiding fields. Capillary interactions provide a versatile route for structure formation. Colloids adsorbed on fluid interfaces distort the interface, which creates an associated energy field. When neighboring distortions overlap, colloids interact to minimize interfacial area. Contact line pinning, particle shape, and surface chemistry play important roles in structure formation. Interface curvature acts like an external field; particles migrate and assemble in patterns dictated by curvature gradients. We review basic analysis and recent findings in this rapidly evolving literature. Understanding the roles of assembly is essential for tuning the mechanical, physical, and optical properties of the structure.

  6. Relation between lowered colloid osmotic pressure, respiratory failure, and death.

    Tonnesen, A S; Gabel, J C; McLeavey, C A

    1977-01-01

    Plasma colloid osmotic pressure was measured each day in 84 intensive care unit patients. Probit analysis demonstrated a direct relationship between colloid osmotic pressure (COP) and survival. The COP associated with a 50% survival rate was 15.0 torr. COP was higher in survivors than in nonsurvivors without respiratory failure and in patients who recovered from respiratory failure. We conclude that lowered COP is associated with an elevated mortality rate. However, the relationship to death is not explained by the relationship to respiratory failure.

  7. Microbial effects on colloidal agglomeration

    Hersman, L.

    1995-11-01

    Colloidal particles are known to enhance the transport of radioactive metals through soil and rock systems. This study was performed to determine if a soil microorganism, isolated from the surface samples collected at Yucca Mountain, NV, could affect the colloidal properties of day particles. The agglomeration of a Wyoming bentonite clay in a sterile uninoculated microbial growth medium was compared to the agglomeration in the medium inoculated with a Pseudomonas sp. In a second experiment, microorganisms were cultured in the succinate medium for 50 h and removed by centrifugation. The agglomeration of the clay in this spent was compared to sterile uninoculated medium. In both experiments, the agglomeration of the clay was greater than that of the sterile, uninoculated control. Based on these results, which indicate that this microorganism enhanced the agglomeration of the bentonite clay, it is possible to say that in the presence of microorganisms colloidal movement through a rock matrix could be reduced because of an overall increase in the size of colloidal particle agglomerates. 32 refs

  8. Characterization of Complex Colloidal Suspensions

    Seaman, J. C.; Guerin, M.; Jackson, B. P.; Ranville, J. M.

    2003-04-01

    Surface chemical reactions play a major role in controlling contaminant fate and transport in the subsurface environment. Recent field and laboratory evidence suggests that mobile soil and groundwater colloids may facilitate the migration of sparingly soluble groundwater contaminants. Colloidal suspensions collected in the field or generated in laboratory column experiments tend to be fairly dilute in nature and comprised of relatively small particulates (reserved for studying ideal systems to the characterization of mobile colloids. However, many of these analytical techniques, including total/selective dissolution methods, dynamic light scattering, micro-electrophoresis, streaming potential, and even scanning electron microscopy (SEM), can be biased in of larger size fractions, and therefore, extremely sensitive to sampling, storage, and fractionation artifacts. In addition, surface modifiers such as sorbed oxides or organics can alter particulate appearance, composition, and behavior when compared to synthetic analogues or mineral standards. The current presentation will discuss the limitations and inherent biases associated with a number of analytical characterization techniques that are commonly applied to the study of mobile soil and groundwater colloids, including field flow fractionation (FFF) and acoustic based methods that have only recently become available.

  9. A short textbook of colloid chemistry

    Jirgensons, B

    1962-01-01

    A Short Textbook of Colloid Chemistry, Second Revised Edition details the factual aspect of colloid chemistry that includes the basic facts, established empirical and mathematical relationships, and practical applications. The chapters of the title are organized into two parts. In the first part, the text discusses the general concepts of colloid chemistry, such as the history and scope, basic terms, and basic methods in experiment with colloids. Part Two covers the technical aspect of colloid chemistry, such as the optical properties, electrical properties, and viscosity. The book will be of

  10. Core Community Specifications for Electron Microprobe Operating Systems: Software, Quality Control, and Data Management Issues

    Fournelle, John; Carpenter, Paul

    2006-01-01

    Modem electron microprobe systems have become increasingly sophisticated. These systems utilize either UNIX or PC computer systems for measurement, automation, and data reduction. These systems have undergone major improvements in processing, storage, display, and communications, due to increased capabilities of hardware and software. Instrument specifications are typically utilized at the time of purchase and concentrate on hardware performance. The microanalysis community includes analysts, researchers, software developers, and manufacturers, who could benefit from exchange of ideas and the ultimate development of core community specifications (CCS) for hardware and software components of microprobe instrumentation and operating systems.

  11. Mapping of trace elements with photon microprobes: x-ray fluorescence with focussed synchrotron radiation

    Hanson, A.L.; Jones, K.W.; Gordon, B.M.; Pounds, J.G.; Rivers, M.L.; Schidlovsky, G.

    1985-04-01

    High energy electron synchrotron storage rings provide copious quantities of polarized photons that make possible the mapping of many trace elements with sensitivities at the parts per billion (ppB) level with spatial resolutions in the micrometer range. The brightness of the x-ray ring of the National Synchrotron Light Source (NSLS), presently being commissioned, will be five orders of magnitude larger than that of the bremsstrahlung spectrum of state-of-the-art rotating anode tubes. We will discuss mapping trace elements with a photon microprobe presently being constructed for use at the NSLS. This microprobe will have micrometer spatial resolution

  12. An x-ray microprobe using focussing optics with a synchrotron radiation source

    Thompson, A.C.; Underwood, J.H.; Wu, Y.; Giauque, R.D.

    1989-01-01

    An x-ray microprobe can be used to produce maps of the concentration of elements in a sample. Synchrotron radiation provides x-ray beams with enough intensity and collimation to make possible elemental images with femtogram sensitivity. The use of focussing x-ray mirrors made from synthetic multilayers with a synchrotron x-ray beam allows beam spot sizes of less than 10 μm /times/ 10 μm to be produced. Since minimal sample preparation is required and a vacuum environment is not necessary, there will be a wide variety of applications for such microprobes. 8 refs., 6 figs

  13. The PNC/XOR x-ray microprobe station at APS sector 20

    Heald, S. M.; Cross, J. O.; Brewe, D. L.; Gordon, R. A.

    2007-01-01

    The X-ray microprobe is the most popular experimental setup at the PNC/XOR insertion device beamline located at sector 20 at the Advanced Photon Source. To satisfy user demand and to simplify the setup, we have developed a dedicated station with multiple detection options. This paper will describe the setup in detail and demonstrate the capabilities with some example imaging, micro-XAS and microdiffraction data. In the future, an improved version of the microprobe will be installed on a dedicated undulator. The improvements planned for this station are based on our operational experience and will also be discussed

  14. Polymer SU-8 Based Microprobes for Neural Recording and Drug Delivery

    Altuna, Ane; Fernandez, Luis; Berganzo, Javier

    2015-06-01

    This manuscript makes a reflection about SU-8 based microprobes for neural activity recording and drug delivery. By taking advantage of improvements in microfabrication technologies and using polymer SU-8 as the only structural material, we developed several microprobe prototypes aimed to: a) minimize injury in neural tissue, b) obtain high-quality electrical signals and c) deliver drugs at a micrometer precision scale. Dedicated packaging tools have been developed in parallel to fulfill requirements concerning electric and fluidic connections, size and handling. After these advances have been experimentally proven in brain using in vivo preparation, the technological concepts developed during consecutive prototypes are discussed in depth now.

  15. POLYMER SU-8 BASED MICROPROBES FOR NEURAL RECORDING AND DRUG DELIVERY

    Ane eAltuna

    2015-06-01

    Full Text Available This manuscript makes a reflection about SU-8 based microprobes for neural activity recording and drug delivery. By taking advantage of improvements in microfabrication technologies and using polymer SU-8 as the only structural material, we developed several microprobe prototypes aimed to: a minimize injury in neural tissue, b obtain high-quality electrical signals and c deliver drugs at a micrometer precision scale. Dedicated packaging tools have been developed in parallel to fulfill requirements concerning electric and fluidic connections, size and handling. After these advances have been experimentally proven in brain using in vivo preparation, the technological concepts developed during consecutive prototypes are discussed in depth now.

  16. Theory of equidistant three-dimensional radiance measurements with optical microprobes RID A-1977-2009

    FukshanskyKazarinova, N.; Fukshansky, L.; Kuhl, Morten

    1996-01-01

    Fiber-optic radiance microprobes, increasingly applied for measurements of internal light fields in living tissues, provide three-dimensional radiance distribution solids and radiant energy fluence rates at different depths of turbid samples. These data are, however, distorted because of an inher...... of application is presented. The limitations of this theory and the prospects for this approach are discussed....... of an inherent feature of optical fibers: nonuniform angular sensitivity. Because of this property a radiance microprobe during a single measurement partly underestimates light from the envisaged direction and partly senses light from other directions. A theory of three-dimensional equidistant radiance...

  17. Normal modes of weak colloidal gels

    Varga, Zsigmond; Swan, James W.

    2018-01-01

    The normal modes and relaxation rates of weak colloidal gels are investigated in calculations using different models of the hydrodynamic interactions between suspended particles. The relaxation spectrum is computed for freely draining, Rotne-Prager-Yamakawa, and accelerated Stokesian dynamics approximations of the hydrodynamic mobility in a normal mode analysis of a harmonic network representing several colloidal gels. We find that the density of states and spatial structure of the normal modes are fundamentally altered by long-ranged hydrodynamic coupling among the particles. Short-ranged coupling due to hydrodynamic lubrication affects only the relaxation rates of short-wavelength modes. Hydrodynamic models accounting for long-ranged coupling exhibit a microscopic relaxation rate for each normal mode, λ that scales as l-2, where l is the spatial correlation length of the normal mode. For the freely draining approximation, which neglects long-ranged coupling, the microscopic relaxation rate scales as l-γ, where γ varies between three and two with increasing particle volume fraction. A simple phenomenological model of the internal elastic response to normal mode fluctuations is developed, which shows that long-ranged hydrodynamic interactions play a central role in the viscoelasticity of the gel network. Dynamic simulations of hard spheres that gel in response to short-ranged depletion attractions are used to test the applicability of the density of states predictions. For particle concentrations up to 30% by volume, the power law decay of the relaxation modulus in simulations accounting for long-ranged hydrodynamic interactions agrees with predictions generated by the density of states of the corresponding harmonic networks as well as experimental measurements. For higher volume fractions, excluded volume interactions dominate the stress response, and the prediction from the harmonic network density of states fails. Analogous to the Zimm model in polymer

  18. Glass/Jamming Transition in Colloidal Aggregation

    Segre, Philip N.; Prasad, Vikram; Weitz, David A.; Rose, M. Franklin (Technical Monitor)

    2000-01-01

    We have studied colloidal aggregation in a model colloid plus polymer system with short-range attractive interactions. By varying the colloid concentration and the strength of the attraction, we explored regions where the equilibrium phase is expected to consist of colloidal crystallites in coexistance with colloidal gas (i.e. monomers). This occurs for moderate values of the potential depth, U approximately equal to 2-5 kT. Crystallization was not always observed. Rather, over an extended sub-region two new metastable phases appear, one fluid-like and one solid-like. These were examined in detail with light scattering and microscopy techniques. Both phases consist of a near uniform distribution of small irregular shaped clusters of colloidal particles. The dynamical and structural characteristics of the ergodic-nonergodic transition between the two phases share much in common with the colloidal hard sphere glass transition.

  19. Measuring Advection and Diffusion of Colloids in Shear Flow

    Duits, Michael H.G.; Ghosh, Somnath; Mugele, Friedrich Gunther

    2015-01-01

    An analysis of the dynamics of colloids in shear flow can be challenging because of the superposition of diffusion and advection. We present a method that separates the two motions, starting from the time-dependent particle coordinates. The restriction of the tracking to flow lanes and the

  20. Quantitative Evaluation of the Total Magnetic Moments of Colloidal Magnetic Nanoparticles: A Kinetics-based Method.

    Liu, Haiyi; Sun, Jianfei; Wang, Haoyao; Wang, Peng; Song, Lina; Li, Yang; Chen, Bo; Zhang, Yu; Gu, Ning

    2015-06-08

    A kinetics-based method is proposed to quantitatively characterize the collective magnetization of colloidal magnetic nanoparticles. The method is based on the relationship between the magnetic force on a colloidal droplet and the movement of the droplet under a gradient magnetic field. Through computational analysis of the kinetic parameters, such as displacement, velocity, and acceleration, the magnetization of colloidal magnetic nanoparticles can be calculated. In our experiments, the values measured by using our method exhibited a better linear correlation with magnetothermal heating, than those obtained by using a vibrating sample magnetometer and magnetic balance. This finding indicates that this method may be more suitable to evaluate the collective magnetism of colloidal magnetic nanoparticles under low magnetic fields than the commonly used methods. Accurate evaluation of the magnetic properties of colloidal nanoparticles is of great importance for the standardization of magnetic nanomaterials and for their practical application in biomedicine. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  1. Sorption and mechanism of aqueous U(Ⅵ) onto red soil-colloid

    Xia Liangshu; Huang Xin; Cao Cuncun; Chen Wei; Lu Junwen

    2013-01-01

    By static adsorption experiments, the effects of pH, ionic strength, adsorption time, uranium initial concentration, adsorbent dosage, red soil-colloid size, and organic matters on the biosorption capacity of red soil-colloid extracted from the soil around uranium tailing for uranium were studied. The adsorption process was analyzed by thermodynamics and kinetics, and the adsorption mechanism was characterized by the element analysis, infrared spectroscopy and scanning electron microscopy. The results show that the adsorption capacity for U (Ⅵ) on red soil-colloid increases with the decrease of ionic strength or particle size, increases with the initial concentration of uranium, decreases with the increase of the amount of red soil-colloid; the saturated adsorption capacity q max can be up to 76.76 μg/mg by red soil-colloid which diameter is less than 1 μm at 25 ℃ and pH=3.5, when the ionic strength is 0.001 mol/L. FT-IR micrograph before and after red soil-colloid adsorbed uranyl ions indicates that the red soil-colloid are mainly composed of hydroxyl, carbonyl, Si-O, Si-O-Fe, etc. The adsorption of U (Ⅵ) on red soil-colloid follows Langmuir adsorption isotherm, and the pseudo-second-order equation provides the best correlation for the adsorption process. (authors)

  2. Three-Dimensional Radionuclide Transport Through the Unsaturated Zone of the Yucca Mountain Site 3 Colloids

    G. J. Moridis; Y. Seol

    2007-01-01

    The authors investigated colloid transport in the unsaturated fractured zone by means of three-dimensional site-scale numerical model under present-day climate infiltration, considering varying colloid diameters, kinetic declogging, and filtration. The radionuclide transport model was used to simulate continuous release of colloids into fractures throughout the proposed repository, in which any components of engineered barrier system such as waste package or drip shield were not considered. the results of the study indicate the importance of subsurface geology and site hydrology, i.e., the presence of faults (they dominate and control transport), fractures (the main migration pathways), and the relative distribution of zeolitic and vitric tuffs. The simulations indicate that (1) colloid transport is not significantly affected by varying the filtration parameters, (2) travel time to the water table decreases with the colloid size, (3) larger colloids show little retardation whereas very small ones are retarded significantly, and (4) fracture filtration can have an impact on transport. Because of uncertainties in the fundamentals of colloid transport and an extremely conservative approach (based on an improbably adverse worst-case scenario), caution should be exercised in the analysis and interpretation of the 3-D simulation results. The results discussed here should be viewed as an attempt to identify and evaluate the mechanisms, processes, and geological features that control colloidal transport

  3. Colloidal Photoluminescent Amorphous Porous Silicon, Methods Of Making Colloidal Photoluminescent Amorphous Porous Silicon, And Methods Of Using Colloidal Photoluminescent Amorphous Porous Silicon

    Chaieb, Sahraoui

    2015-04-09

    Embodiments of the present disclosure provide for a colloidal photoluminescent amorphous porous silicon particle suspension, methods of making a colloidal photoluminescent amorphous porous silicon particle suspension, methods of using a colloidal photoluminescent amorphous porous silicon particle suspension, and the like.

  4. Colloidal Photoluminescent Amorphous Porous Silicon, Methods Of Making Colloidal Photoluminescent Amorphous Porous Silicon, And Methods Of Using Colloidal Photoluminescent Amorphous Porous Silicon

    Chaieb, Saharoui; Mughal, Asad Jahangir

    2015-01-01

    Embodiments of the present disclosure provide for a colloidal photoluminescent amorphous porous silicon particle suspension, methods of making a colloidal photoluminescent amorphous porous silicon particle suspension, methods of using a colloidal photoluminescent amorphous porous silicon particle suspension, and the like.

  5. Magnetic Assisted Colloidal Pattern Formation

    Yang, Ye

    Pattern formation is a mysterious phenomenon occurring at all scales in nature. The beauty of the resulting structures and myriad of resulting properties occurring in naturally forming patterns have attracted great interest from scientists and engineers. One of the most convenient experimental models for studying pattern formation are colloidal particle suspensions, which can be used both to explore condensed matter phenomena and as a powerful fabrication technique for forming advanced materials. In my thesis, I have focused on the study of colloidal patterns, which can be conveniently tracked in an optical microscope yet can also be thermally equilibrated on experimentally relevant time scales, allowing for ground states and transitions between them to be studied with optical tracking algorithms. In particular, I have focused on systems that spontaneously organize due to particle-surface and particle-particle interactions, paying close attention to systems that can be dynamically adjusted with an externally applied magnetic or acoustic field. In the early stages of my doctoral studies, I developed a magnetic field manipulation technique to quantify the adhesion force between particles and surfaces. This manipulation technique is based on the magnetic dipolar interactions between colloidal particles and their "image dipoles" that appear within planar substrate. Since the particles interact with their own images, this system enables massively parallel surface force measurements (>100 measurements) in a single experiment, and allows statistical properties of particle-surface adhesion energies to be extracted as a function of loading rate. With this approach, I was able to probe sub-picoNewton surface interactions between colloidal particles and several substrates at the lowest force loading rates ever achieved. In the later stages of my doctoral studies, I focused on studying patterns formed from particle-particle interaction, which serve as an experimental model of

  6. Statistical Physics of Colloidal Dispersions.

    Canessa, E.

    Available from UMI in association with The British Library. Requires signed TDF. This thesis is concerned with the equilibrium statistical mechanics of colloidal dispersions which represent useful model systems for the study of condensed matter physics; namely, charge stabilized colloidal dispersions and polymer stabilized colloidal dispersions. A one-component macroparticle approach is adopted in order to treat the macroscopic and microscopic properties of these systems in a simple and comprehensive manner. The thesis opens with the description of the nature of the colloidal state before reviewing some basic definitions and theory in Chapter II. In Chapter III a variational theory of phase equilibria based on the Gibbs-Bogolyobov inequality is applied to sterically stabilized colloidal dispersions. Hard spheres are chosen as the reference system for the disordered phases while an Einstein model is used for the ordered phases. The new choice of pair potential, taken for mathematical convenience, is a superposition of two Yukawa functions. By matching a double Yukawa potential to the van der Waals attractive potential at different temperatures and introducing a purely temperature dependent coefficient to the repulsive part, a rich variety of observed phase separation phenomena is qualitatively described. The behaviour of the potential is found to be consistent with a small decrease of the polymer layer thickness with increasing temperature. Using the same concept of a collapse transition the non-monotonic second virial coefficient is also explained and quantified. It is shown that a reduction of the effective macroparticle diameter with increasing temperature can only be partially examined from the point of view of a (binary-) polymer solution theory. This chapter concludes with the description of the observed, reversible, depletion flocculation behaviour. This is accomplished by using the variational formalism and by invoking the double Yukawa potential to allow

  7. Quantifying trace elements in individual aquatic protist cells with a synchrotron x-ray fluorescence microprobe

    Twining, B.S.; Baines, S.B.; Fisher, N.S.; Maser, J.; Vogt, S.; Jacobsen, C.; Tovar-Sanchez, A.; Sanudo-Wihelmy, S.A.

    2003-01-01

    The study of trace metal cycling by aquatic protists is limited by current analytical techniques. Standard 'bulk' element analysis techniques that rely on physical separations to concentrate cells for analysis cannot separate cells from co-occurring detrital material or other cells of differing taxonomy or trophic function. Here we demonstrate the ability of a synchrotron-based X-ray fluorescence (SXRF) microprobe to quantify the elements Si, Mn, Fe, Ni, and Zn in individual aquatic protist cells. This technique distinguishes between different types of cells in an assemblage and between cells and other particulate matter. Under typical operating conditions, the minimum detection limits are 7.0 x 10 -16 mol μm -2 for Si and between 5.0 x 10 -20 and 3.9 x 10 -19 mol μm -2 for Mn, Fe, Ni, and Zn; this sensitivity is sufficient to detect these elements in cells from even the most pristine waters as demonstrated in phytoplankton cells collected from remote areas of the Southern Ocean. Replicate analyses of single cells produced variations of <5% for Si, Mn, Fe, and Zn and <10% for Ni. Comparative analyses of cultured phytoplankton cells generally show no significant differences in cellular metal concentrations measured with SXRF and standard bulk techniques (spectrophotometry and graphite furnace atomic absorption spectrometry). SXRF also produces two-dimensional maps of element distributions in cells, thereby providing information not available with other analytical approaches. This technique enables the accurate and precise measurement of trace metals in individual aquatic protists collected from natural environments.

  8. On the identification of carbonaceous aerosols via 14C accelerator mass spectrometry, and laser microprobe mass spectrometry

    Currie, L.A.; Fletcher, R.A.; Klouda, G.A.

    1987-01-01

    Carbon isotopic measurements ( 12 C, 14 C), derived from chemical measurements of total carbon plus AMS measurements of 14 C/ 12 C have become an accepted means for estimating fossil and contemporary carbon source contributions to atmospheric carbon. Because of the limited sensitivity of these techniques, however, such measurements are restricted to 'bulk' samples comprising at least 10-100 μg of carbon. Laser microprobe mass spectrometry (LMMS) offers an important complementary opportunity to investigate the chemical nature of individual particles as small as 0.1 μm in diameter. Although there is little hope to measure 14 C/ 12 C in such small samples, the compositional and structural information available with the laser microprobe is of interest for possible source discrimination. Also, the analysis of individual particles, which may reflect individual sources, yields significant potential increases in spatial, temporal and source resolution, in comparison to bulk sample analysis. Results of our exploratory investigation of known sources of carbonaceous particles, using LMMS, are presented. By applying multivariate techniques to laser mass spectra of soot from the combustion of heptane and wood, we found striking differences in the alkali metals (notably potassium) in the positive ion mass spectra. For ambient particles, 14 C has proved to be a crucial adjunct for the development and validation of the LMMS approach to single particle source assignment via carbon cluster pattern recognition. The combined techniques offer great promise for objective modeling (number and types of carbon sources) and for extension of the dichotomous carbon apportionment (fossil, contemporary) to subclasses such as soot from wood and agricultural burning, and that from coal and petroleum combustion. (orig.)

  9. Simulation of bentonite colloid migration through granite

    Rosicka, Dana; Hokr, Milan

    2012-01-01

    Document available in extended abstract form only. Full text of publication follows: Colloidal bentonite particles generate at the interface of buffer and host rock in spent nuclear fuel repository due to an erosion process and migrate through granite by the water flow. Stability of these colloids and their migration possibilities have been studied on account of radionuclide transport possibility as colloid could carry adsorbed radionuclides in groundwater through granite. That is why a simulation of bentonite colloid migration in the surrounding of a repository might be requested. According to chemical condition as ionic strength and pH, the colloidal particles coagulate into clusters and that influence the migration of particles. The coagulation kinetics of natural bentonite colloids were experimentally studied in many articles, for example by light scattering techniques. We created a model of coagulation of bentonite colloids and simulation of a chosen experiment with use of the multicomponent reactive transport equation. The coagulation model describes clustering of particles due to attractive van der Waals forces as result of collision of particles due to heat fluctuation and different velocity of particles during sedimentation and velocity gradient of water flow. Next, the model includes influence of repulsive electrostatic forces among colloidal particles leading to stability of particles provided high surface charge of colloids. In the model, each group of clusters is transported as one solution component and the kinetics of coagulation are implemented as reactions between the components: a shift of particles among groups of particles with similar migration properties, according to size of the clusters of colloids. The simulation of migration of bentonite colloid through granite using the coagulation model was calibrated according to experiment results. On the basis of the simulation, one can estimate the basic processes that occur during bentonite colloid

  10. Round robin: Quantitative lateral resolution of PHI XPS microprobes Quantum 2000/Quantera SXM

    Scheithauer, Uwe; Kolb, Max; Kip, Gerard A.M.; Naburgh, Emile; Snijders, J.H.M.

    2016-01-01

    Highlights: • The quantitative lateral resolution of 7 PHI XPS microprobes has been estimated in a round robin. • An ellipsoidally shaped quartz crystal monochromatizes the Alkα radiation and refocuses it from the Al anode to the sample surface. • The long tail contributions of the X-ray beam intensity distribution were measured using a new and innovative approach. • This quantitative lateral resolution has a significantly larger value than the nominal X-ray beam diameter. • The quantitative lateral resolution follows a trend in time: The newer the monochromator so much the better the quantitative lateral resolution. - Abstract: The quantitative lateral resolution is a reliable measure for the quality of an XPS microprobe equipped with a focused X-ray beam. It describes the long tail contributions of the X-ray beam intensity distribution. The knowledge of these long tail contributions is essential when judging on the origin of signals of XPS spectra recorded on small-sized features. In this round robin test the quantitative lateral resolution of 7 PHI XPS microprobes has been estimated. As expected, the quantitative lateral resolution has significantly larger values than the nominal X-ray beam diameter. The estimated values of the quantitative lateral resolution follow a trend in time: the newer the monochromator of an XPS microprobe so much the better the quantitative lateral resolution.

  11. Round robin: Quantitative lateral resolution of PHI XPS microprobes Quantum 2000/Quantera SXM

    Scheithauer, Uwe, E-mail: scht.uhg@googlemail.com [82008 Unterhaching (Germany); Kolb, Max, E-mail: max.kolb@airbus.com [Airbus Group Innovations, TX2, 81663 Munich (Germany); Kip, Gerard A.M., E-mail: G.A.M.Kip@utwente.nl [Universiteit Twente, MESA+ Nanolab, Postbus 217, 7500AE Enschede (Netherlands); Naburgh, Emile, E-mail: e.p.naburgh@philips.com [Materials Analysis, Philips Innovation Services, High Tech Campus 11, 5656 AE Eindhoven (Netherlands); Snijders, J.H.M., E-mail: j.h.m.snijders@philips.com [Materials Analysis, Philips Innovation Services, High Tech Campus 11, 5656 AE Eindhoven (Netherlands)

    2016-07-15

    Highlights: • The quantitative lateral resolution of 7 PHI XPS microprobes has been estimated in a round robin. • An ellipsoidally shaped quartz crystal monochromatizes the Alkα radiation and refocuses it from the Al anode to the sample surface. • The long tail contributions of the X-ray beam intensity distribution were measured using a new and innovative approach. • This quantitative lateral resolution has a significantly larger value than the nominal X-ray beam diameter. • The quantitative lateral resolution follows a trend in time: The newer the monochromator so much the better the quantitative lateral resolution. - Abstract: The quantitative lateral resolution is a reliable measure for the quality of an XPS microprobe equipped with a focused X-ray beam. It describes the long tail contributions of the X-ray beam intensity distribution. The knowledge of these long tail contributions is essential when judging on the origin of signals of XPS spectra recorded on small-sized features. In this round robin test the quantitative lateral resolution of 7 PHI XPS microprobes has been estimated. As expected, the quantitative lateral resolution has significantly larger values than the nominal X-ray beam diameter. The estimated values of the quantitative lateral resolution follow a trend in time: the newer the monochromator of an XPS microprobe so much the better the quantitative lateral resolution.

  12. Characterization of Alq3 thin films by a near-field microwave microprobe.

    Hovsepyan, Artur; Lee, Huneung; Sargsyan, Tigran; Melikyan, Harutyun; Yoon, Youngwoon; Babajanyan, Arsen; Friedman, Barry; Lee, Kiejin

    2008-09-01

    We observed tris-8-hydroxyquinoline aluminum (Alq3) thin films dependence on substrate heating temperatures by using a near-field microwave microprobe (NFMM) and by optical absorption at wavelengths between 200 and 900 nm. The changes of absorption intensity at different substrate heating temperatures are correlated to the changes in the sheet resistance of Alq3 thin films.

  13. Scanning deep level transient spectroscopy using an MeV ion microprobe

    Laird, J S; Bardos, R A; Saint, A; Moloney, G M; Legge, G F.J. [Melbourne Univ., Parkville, VIC (Australia)

    1994-12-31

    Traditionally the scanning ion microprobe has given little or no information regarding the electronic structure of materials in particular semiconductors. A new imaging technique called Scanning Ion Deep Level Transient Spectroscopy (SIDLTS) is presented which is able to spatially map alterations in the band gap structure of materials by lattice defects or impurities. 3 refs., 2 figs.

  14. Scanning deep level transient spectroscopy using an MeV ion microprobe

    Laird, J.S.; Bardos, R.A.; Saint, A.; Moloney, G.M.; Legge, G.F.J. [Melbourne Univ., Parkville, VIC (Australia)

    1993-12-31

    Traditionally the scanning ion microprobe has given little or no information regarding the electronic structure of materials in particular semiconductors. A new imaging technique called Scanning Ion Deep Level Transient Spectroscopy (SIDLTS) is presented which is able to spatially map alterations in the band gap structure of materials by lattice defects or impurities. 3 refs., 2 figs.

  15. Developments of new generation nuclear microprobe systems at the University of Melbourne

    Rout, B.; Jamieson, D.N.; Hopt, R.; Hearne, S.; Szymaski, R.

    2002-01-01

    Full text: A review of the recent developments in fabricating a new generation nuclear microprobe systems at University of Melbourne, Melbourne, will be presented. These new generation systems present high spatial resolution (less than 1 micrometer) with increasing current density (in excess of 100 pA/micrometer 2 ) of the probing ion beam. Detectors with large solid angles and high brightness of the ion source of the accelerator increase the capabilities of these microprobes many fold. Some of the key ingredients of these microprobes are (i) novel magnetic quadrupole lens quintuplet probe forming system (ii) integrated fast data acquisition system to handle high count rates (excess of 100 KHz) due to increasing current density as well as large detector solid angles up to 4 detector stations. Full dead time corrected and charge normalised maps are also implemented to counter the problems normally associated with such high count rate systems. First version of these systems is presently under operation at CSIRO, Sydney. Another similar system is currently being installed at Dutch Institute for Nuclear and High Energy Physics, Amsterdam, Netherlands. A further optimised version of the CSIRO/MARC quintuplet probe forming systems is currently being fabricated at University of Melbourne. Some of the applications involve microelectronic materials, superconductors and geological samples. We will be presenting exciting results arising out of investigations into these materials. We will be demonstrating ultimate spatial resolution of the new microprobe being fabricated at Melbourne

  16. CTCN: Colloid transport code -- nuclear

    Jain, R.

    1993-01-01

    This report describes the CTCN computer code, designed to solve the equations of transient colloidal transport of radionuclides in porous and fractured media. This Fortran 77 package solves systems of coupled nonlinear differential-algebraic equations with a wide range of boundary conditions. The package uses the Method of Lines technique with a special section which forms finite-difference discretizations in up to four spatial dimensions to automatically convert the system into a set of ordinary differential equations. The CTCN code then solves these equations using a robust, efficient ODE solver. Thus CTCN can be used to solve population balance equations along with the usual transport equations to model colloid transport processes or as a general problem solver to treat up to four-dimensional differential-algebraic systems

  17. THE COLLOIDAL BEHAVIOR OF EDESTIN

    Hitchcock, David I.

    1922-01-01

    1. It has been shown by titration experiments that the globulin edestin behaves like an amphoteric electrolyte, reacting stoichiometrically with acids and bases. 2. The potential difference developed between a solution of edestin chloride or acetate separated by a collodion membrane from an acid solution free from protein was found to be influenced by salt concentration and hydrogen ion concentration in the way predicted by Donnan's theory of membrane equilibrium. 3. The osmotic pressure of such edestin-acid salt solutions was found to be influenced by salt concentration and by hydrogen ion concentration in the same way as is the potential difference. 4. The colloidal behavior of edestin is thus completely analogous to that observed by Loeb with gelatin, casein, and egg albumin, and may be explained by Loeb's theory of colloidal behavior, which is based on the idea that proteins react stoichiometrically as amphoteric electrolytes and on Donnan's theory of membrane equilibrium. PMID:19871959

  18. Kinetically guided colloidal structure formation

    Hecht, Fabian M.; Bausch, Andreas R.

    2016-01-01

    The well-studied self-organization of colloidal particles is predicted to result in a variety of fascinating applications. Yet, whereas self-assembly techniques are extensively explored, designing and producing mesoscale-sized objects remains a major challenge, as equilibration times and thus structure formation timescales become prohibitively long. Asymmetric mesoscopic objects, without prior introduction of asymmetric particles with all its complications, are out of reach––due to the underl...

  19. Glass transition of soft colloids

    Philippe, Adrian-Marie; Truzzolillo, Domenico; Galvan-Myoshi, Julian; Dieudonné-George, Philippe; Trappe, Véronique; Berthier, Ludovic; Cipelletti, Luca

    2018-04-01

    We explore the glassy dynamics of soft colloids using microgels and charged particles interacting by steric and screened Coulomb interactions, respectively. In the supercooled regime, the structural relaxation time τα of both systems grows steeply with volume fraction, reminiscent of the behavior of colloidal hard spheres. Computer simulations confirm that the growth of τα on approaching the glass transition is independent of particle softness. By contrast, softness becomes relevant at very large packing fractions when the system falls out of equilibrium. In this nonequilibrium regime, τα depends surprisingly weakly on packing fraction, and time correlation functions exhibit a compressed exponential decay consistent with stress-driven relaxation. The transition to this novel regime coincides with the onset of an anomalous decrease in local order with increasing density typical of ultrasoft systems. We propose that these peculiar dynamics results from the combination of the nonequilibrium aging dynamics expected in the glassy state and the tendency of colloids interacting through soft potentials to refluidize at high packing fractions.

  20. Implant materials modified by colloids

    Zboromirska-Wnukiewicz Beata

    2016-03-01

    Full Text Available Recent advances in general medicine led to the development of biomaterials. Implant material should be characterized by a high biocompatibility to the tissue and appropriate functionality, i.e. to have high mechanical and electrical strength and be stable in an electrolyte environment – these are the most important properties of bioceramic materials. Considerations of biomaterials design embrace also electrical properties occurring on the implant-body fluid interface and consequently the electrokinetic potential, which can be altered by modifying the surface of the implant. In this work, the surface of the implants was modified to decrease the risk of infection by using metal colloids. Nanocolloids were obtained using different chemical and electrical methods. It was found that the colloids obtained by physical and electrical methods are more stable than colloids obtained by chemical route. In this work the surface of modified corundum implants was investigated. The implant modified by nanosilver, obtained by electrical method was selected. The in vivo research on animals was carried out. Clinical observations showed that the implants with modified surface could be applied to wounds caused by atherosclerotic skeleton, for curing the chronic and bacterial inflammations as well as for skeletal reconstruction surgery.

  1. Morphological instability of a non-equilibrium ice-colloid interface

    Peppin, S. S. L.; Majumdar, A.; Wettlaufer, J. S.

    2009-01-01

    in frozen clays. A weakly nonlinear analysis yields a long-wave evolution equation for the interface shape containing a new parameter related to the highly nonlinear liquidus curve in colloidal systems. We discuss the implications of these results

  2. Sensitivity analyses of a colloid-facilitated contaminant transport model for unsaturated heterogeneous soil conditions.

    Périard, Yann; José Gumiere, Silvio; Rousseau, Alain N.; Caron, Jean

    2013-04-01

    Certain contaminants may travel faster through soils when they are sorbed to subsurface colloidal particles. Indeed, subsurface colloids may act as carriers of some contaminants accelerating their translocation through the soil into the water table. This phenomenon is known as colloid-facilitated contaminant transport. It plays a significant role in contaminant transport in soils and has been recognized as a source of groundwater contamination. From a mechanistic point of view, the attachment/detachment of the colloidal particles from the soil matrix or from the air-water interface and the straining process may modify the hydraulic properties of the porous media. Šimůnek et al. (2006) developed a model that can simulate the colloid-facilitated contaminant transport in variably saturated porous media. The model is based on the solution of a modified advection-dispersion equation that accounts for several processes, namely: straining, exclusion and attachement/detachement kinetics of colloids through the soil matrix. The solutions of these governing, partial differential equations are obtained using a standard Galerkin-type, linear finite element scheme, implemented in the HYDRUS-2D/3D software (Šimůnek et al., 2012). Modeling colloid transport through the soil and the interaction of colloids with the soil matrix and other contaminants is complex and requires the characterization of many model parameters. In practice, it is very difficult to assess actual transport parameter values, so they are often calibrated. However, before calibration, one needs to know which parameters have the greatest impact on output variables. This kind of information can be obtained through a sensitivity analysis of the model. The main objective of this work is to perform local and global sensitivity analyses of the colloid-facilitated contaminant transport module of HYDRUS. Sensitivity analysis was performed in two steps: (i) we applied a screening method based on Morris' elementary

  3. CALCMIN - an EXCEL™ Visual Basic application for calculating mineral structural formulae from electron microprobe analyses

    Brandelik, Andreas

    2009-07-01

    CALCMIN, an open source Visual Basic program, was implemented in EXCEL™. The program was primarily developed to support geoscientists in their routine task of calculating structural formulae of minerals on the basis of chemical analysis mainly obtained by electron microprobe (EMP) techniques. Calculation programs for various minerals are already included in the form of sub-routines. These routines are arranged in separate modules containing a minimum of code. The architecture of CALCMIN allows the user to easily develop new calculation routines or modify existing routines with little knowledge of programming techniques. By means of a simple mouse-click, the program automatically generates a rudimentary framework of code using the object model of the Visual Basic Editor (VBE). Within this framework simple commands and functions, which are provided by the program, can be used, for example, to perform various normalization procedures or to output the results of the computations. For the clarity of the code, element symbols are used as variables initialized by the program automatically. CALCMIN does not set any boundaries in complexity of the code used, resulting in a wide range of possible applications. Thus, matrix and optimization methods can be included, for instance, to determine end member contents for subsequent thermodynamic calculations. Diverse input procedures are provided, such as the automated read-in of output files created by the EMP. Furthermore, a subsequent filter routine enables the user to extract specific analyses in order to use them for a corresponding calculation routine. An event-driven, interactive operating mode was selected for easy application of the program. CALCMIN leads the user from the beginning to the end of the calculation process.

  4. Crystallization of DNA-coated colloids

    Wang, Yu; Wang, Yufeng; Zheng, Xiaolong; Ducrot, Étienne; Yodh, Jeremy S.; Weck, Marcus; Pine, David J.

    2015-01-01

    DNA-coated colloids hold great promise for self-assembly of programmed heterogeneous microstructures, provided they not only bind when cooled below their melting temperature, but also rearrange so that aggregated particles can anneal into the structure that minimizes the free energy. Unfortunately, DNA-coated colloids generally collide and stick forming kinetically arrested random aggregates when the thickness of the DNA coating is much smaller than the particles. Here we report DNA-coated colloids that can rearrange and anneal, thus enabling the growth of large colloidal crystals from a wide range of micrometre-sized DNA-coated colloids for the first time. The kinetics of aggregation, crystallization and defect formation are followed in real time. The crystallization rate exhibits the familiar maximum for intermediate temperature quenches observed in metallic alloys, but over a temperature range smaller by two orders of magnitude, owing to the highly temperature-sensitive diffusion between aggregated DNA-coated colloids. PMID:26078020

  5. FEBEX bentonite colloid stability in ground water

    Seher, H.; Schaefer, T.; Geckeis, H. [Inst. fuer Nukleare Entsorgung (INE), Forschungszentrum Karlsruhe, 76021 Karlsruhe (Germany)]. e-mail: holger.seher@ine.fzk .de; Fanghaenel, T. [Ruprecht-Karls-Univ. Heidelberg, Physikalisch-Chemisches In st., D-69120 Heidelberg (Germany)

    2007-06-15

    Coagulation experiments are accomplished to identify the geochemical conditions for the stability of Febex bentonite colloids in granite ground water. The experiments are carried out by varying pH, ionic strength and type of electrolyte. The dynamic light scattering technique (photon correlation spectroscopy) is used to measure the size evolution of the colloids with time. Agglomeration rates are higher in MgCl{sub 2} and CaCl{sub 2} than in NaCl solution. Relative agglomeration rates follow approximately the Schulze-Hardy rule. Increasing agglomeration rates at pH>8 are observed in experiments with MgCl{sub 2} and CaCl{sub 2} which are, however, caused by coprecipitation phenomena. Bentonite colloid stability fields derived from the colloid agglomeration experiments predict low colloid stabilization in granite ground water taken from Aespoe, Sweden, and relatively high colloid stability in Grimsel ground water (Switzerland)

  6. Preparation of radioactive colloidal gold 198Au

    Cammarosano, S.A.

    1979-01-01

    The preparation with simple equipment of radioactive colloidal gold of particle size about approximately 300 A from seed colloid stabilized by gelatine is described. Some physico-chemical parameters which can affect the process of formation of these colloidal particles are analysed; particle size has been meassured with an electron microscope. The colloid stability has been studied as a function of dilution, age and pH. Nucleation and growth of radioactive colloidal gold have been studied using spectrophotometry. Absorption spectra of the two ones are presented and compared. Quality control of the production process is verified through measurement of parameters, such as radioactive and radiochemical purity and biological distribution in laboratorial animals. This distribution was evalusted for rats injected endovenously with the gold colloidal solution.(Author) [pt

  7. Thermodynamic stabilization of colloids

    Stol, R.J.; Bruyn, P.L. de

    An analysis is given of the conditions necessary for obtaining a thermodynamically stable dispersion (TSD) of solid particles in a continuous aqueous solution phase. The role of the adsorption of potential-determining ions at the planar interface in lowering the interfacial free energy (γ) to

  8. A novel technique for producing antibody-coated microprobes using a thiol-terminal silane and a heterobifunctional crosslinker.

    Routh, V H; Helke, C J

    1997-02-01

    Antibody-coated microprobes are used to measure neuropeptide release in the central nervous system. Although they are not quantitative, they provide the most precise spatial resolution of the location of in vivo release of any currently available method. Previous methods of coating antibody microprobes are difficult and time-consuming. Moreover, using these methods we were unable to produce evenly coated antibody microprobes. This paper describes a novel method for the production of antibody microprobes using thiol-terminal silanes and the heterobifunctional crosslinker, 4-(4-N-maleimidophenyl)butyric acid hydrazide HCl 1/2 dioxane (MPBH). Following silation, glass micropipettes are incubated with antibody to substance P (SP) that has been conjugated to MPBH. This method results in a dense, even coating of antibody without decreasing the biological activity of the antibody. Additionally, this method takes considerably less time than previously described methods without sacrificing the use of antibody microprobes as micropipettes. The sensitivity of the microprobes for SP is in the picomolar range, and there is a linear correlation between the log of SP concentration (M) and B/B0 (r2 = 0.98). The microprobes are stable for up to 3 weeks when stored in 0.1 M sodium phosphate buffer with 50 mM NaCl (pH 7.4) at 5 degrees C. Finally, insertion into the exposed spinal cord of an anesthetized rat for 15 min produces no damage to the antibody coating.

  9. Simulating colloid hydrodynamics with lattice Boltzmann methods

    Cates, M E; Stratford, K; Adhikari, R; Stansell, P; Desplat, J-C; Pagonabarraga, I; Wagner, A J

    2004-01-01

    We present a progress report on our work on lattice Boltzmann methods for colloidal suspensions. We focus on the treatment of colloidal particles in binary solvents and on the inclusion of thermal noise. For a benchmark problem of colloids sedimenting and becoming trapped by capillary forces at a horizontal interface between two fluids, we discuss the criteria for parameter selection, and address the inevitable compromise between computational resources and simulation accuracy

  10. Hydrodynamic interactions in active colloidal crystal microrheology

    Weeber, R; Harting, JDR Jens

    2012-01-01

    In dense colloids it is commonly assumed that hydrodynamic interactions do not play a role. However, a found theoretical quantification is often missing. We present computer simulations that are motivated by experiments where a large colloidal particle is dragged through a colloidal crystal. To qualify the influence of long-ranged hydrodynamics, we model the setup by conventional Langevin dynamics simulations and by an improved scheme with limited hydrodynamic interactions. This scheme signif...

  11. Conductivity maximum in a charged colloidal suspension

    Bastea, S

    2009-01-27

    Molecular dynamics simulations of a charged colloidal suspension in the salt-free regime show that the system exhibits an electrical conductivity maximum as a function of colloid charge. We attribute this behavior to two main competing effects: colloid effective charge saturation due to counterion 'condensation' and diffusion slowdown due to the relaxation effect. In agreement with previous observations, we also find that the effective transported charge is larger than the one determined by the Stern layer and suggest that it corresponds to the boundary fluid layer at the surface of the colloidal particles.

  12. Colloidal paradigm in supercapattery electrode systems

    Chen, Kunfeng; Xue, Dongfeng

    2018-01-01

    Among decades of development, electrochemical energy storage systems are now sorely in need of a new design paradigm at the nano size and ion level to satisfy the higher energy and power demands. In this review paper, we introduce a new colloidal electrode paradigm for supercapattery that integrates multiple-scale forms of matter, i.e. ion clusters, colloidal ions, and nanosized materials, into one colloid system, coupled with multiple interactions, i.e. electrostatic, van der Waals forces, and chemical bonding, thus leading to the formation of many redox reactive centers. This colloidal electrode not only keeps the original ionic nature in colloidal materials, but also creates a new attribute of high electroactivity. Colloidal supercapattery is a perfect application example of the novel colloidal electrode, leading to higher specific capacitance than traditional electrode materials. The high electroactivity of the colloidal electrode mainly comes from the contribution of exposed reactive centers, owing to the confinement effect of carbon and a binder matrix. Systematic and thorough research on the colloidal system will significantly promote the development of fundamental science and the progress of advanced energy storage technology.

  13. Colloid Titration--A Rapid Method for the Determination of Charged Colloid.

    Ueno, Keihei; Kina, Ken'yu

    1985-01-01

    "Colloid titration" is a volumetric method for determining charged polyelectrolytes in aqueous solutions. The principle of colloid titration, reagents used in the procedure, methods of endpoint detection, preparation of reagent solutions, general procedure used, results obtained, and pH profile of colloid titration are considered. (JN)

  14. An evaluation of acute toxicity of colloidal silver nanoparticles.

    Maneewattanapinyo, Pattwat; Banlunara, Wijit; Thammacharoen, Chuchaat; Ekgasit, Sanong; Kaewamatawong, Theerayuth

    2011-11-01

    Tests for acute oral toxicity, eye irritation, corrosion and dermal toxicity of colloidal silver nanoparticles (AgNPs) were conducted in laboratory animals following OECD guidelines. Oral administration of AgNPs at a limited dose of 5,000 mg/kg produced neither mortality nor acute toxic signs throughout the observation period. Percentage of body weight gain of the mice showed no significant difference between control and treatment groups. In the hematological analysis, there was no significant difference between mice treated with AgNPs and controls. Blood chemistry analysis also showed no differences in any of the parameter examined. There was neither any gross lesion nor histopathological change observed in various organs. The results indicated that the LD(50) of colloidal AgNPs is greater than 5,000 mg/kg body weight. In acute eye irritation and corrosion study, no mortality and toxic signs were observed when various doses of colloidal AgNPs were instilled in guinea pig eyes during 72 hr observation period. However, the instillation of AgNPs at 5,000 ppm produced transient eye irritation during early 24 hr observation time. No any gross abnormality was noted in the skins of the guinea pigs exposed to various doses of colloidal AgNPs. In addition, no significant AgNPs exposure relating to dermal tissue changes was observed microscopically. In summary, these findings of all toxicity tests in this study suggest that colloidal AgNPs could be relatively safe when administered to oral, eye and skin of the animal models for short periods of time.

  15. Modeling of the geochemical behaviour and of the radionuclide transport in the presence of colloids

    Van der Lee, Jan

    1997-01-01

    Over the past ten years, colloids have been introduced in the already complex subject of waste storage safety analysis. They are indeed often considered as rapid carriers for otherwise insoluble radioactive elements, and therefore potentially decrease the effective barrier function of the geological rock surrounding the waste. The problem is therefore to understand colloid behaviour and quantify their stability and reactivity with respect to the radionuclides. The subject reveals three different levels of phenomena: the geochemical mechanisms, the micro-physical and electrostatic behaviour of colloids and the transport mechanisms. The topics of this thesis therefore cover a wide range of disciplines, such as geochemistry, radiochemistry, physics, hydrogeology, mathematics and computer science. Given the complexity of the subject, only strongly simplified models are used for safety assessment including the impact of colloids. Henceforth, the objective of this study is to provide a comprehensive theoretical basis for modelling the impact of colloids according to a deterministic approach, in the hope to pave the road towards predictive modelling of a waste repository performance. This thesis is the result of work carried out in different European Community projects in the framework of the fourth R and D program on 'Management and Storage of Radioactive Waste'. part A, task 4, 'Disposal of Radioactive Waste'. Grateful use has been made of many chemical and hydrogeological experiments carried out by many different laboratories all over Europe. The main results can be classified according to three principal topics: - geochemistry and the chemical behaviour of actinides, lanthanides and fission products; - retention mechanisms of colloidal particles; - transport mechanism in geological medium. The first topic is fundamental: geochemistry forms the basis of e.g. the retention model for aqueous and colloidal species. The principal result of this topic is

  16. Colloid cyst of the third cerebral ventricle with an embryological remnant consistent with paraphysis cerebri in an adult human.

    Nagaraju, S; O'Donovan, D G; Cross, J; Fernandes, H

    2010-01-01

    The histogenesis of colloid cysts of the third ventricle remains unsettled. Initial theories favored a neuroepithelial (paraphysis, ependyma, choroid plexus) origin and some investigators based on morphologic analysis have offered an alternative endodermal source. We report a case of colloid cyst of the third ventricle arising in association with a remnant which we believe corresponds to the paraphysis cerebri in man.

  17. Colloid transport in dual-permeability media

    Leij, Feike J.; Bradford, Scott A.

    2013-07-01

    It has been widely reported that colloids can travel faster and over longer distances in natural structured porous media than in uniform structureless media used in laboratory studies. The presence of preferential pathways for colloids in the subsurface environment is of concern because of the increased risks for disease caused by microorganisms and colloid-associated contaminants. This study presents a model for colloid transport in dual-permeability media that includes reversible and irreversible retention of colloids and first-order exchange between the aqueous phases of the two regions. The model may also be used to describe transport of other reactive solutes in dual-permeability media. Analytical solutions for colloid concentrations in aqueous and solid phases were obtained using Laplace transformation and matrix decomposition. The solutions proved convenient to assess the effect of model parameters on the colloid distribution. The analytical model was used to describe effluent concentrations for a bromide tracer and 3.2- or 1-μm-colloids that were observed after transport through a composite 10-cm long porous medium made up of a cylindrical lens or core of sand and a surrounding matrix with sand of a different grain size. The tracer data were described very well and realistic estimates were obtained for the pore-water velocity in the two flow domains. An accurate description was also achieved for most colloid breakthrough curves. Dispersivity and retention parameters were typically greater for the larger 3.2-μm-colloids while both reversible and irreversible retention rates tended to be higher for the finer sands than the coarser sand. The relatively small sample size and the complex flow pattern in the composite medium made it difficult to reach definitive conclusions regarding transport parameters for colloid transport.

  18. Waste Form and Indrift Colloids-Associated Radionuclide Concentrations: Abstraction and Summary

    Aguilar, R.

    2003-01-01

    This Model Report describes the analysis and abstractions of the colloids process model for the waste form and engineered barrier system components of the total system performance assessment calculations to be performed with the Total System Performance Assessment-License Application model. Included in this report is a description of (1) the types and concentrations of colloids that could be generated in the waste package from degradation of waste forms and the corrosion of the waste package materials, (2) types and concentrations of colloids produced from the steel components of the repository and their potential role in radionuclide transport, and (3) types and concentrations of colloids present in natural waters in the vicinity of Yucca Mountain. Additionally, attachment/detachment characteristics and mechanisms of colloids anticipated in the repository are addressed and discussed. The abstraction of the process model is intended to capture the most important characteristics of radionuclide-colloid behavior for use in predicting the potential impact of colloid-facilitated radionuclide transport on repository performance

  19. Waste Form and Indrift Colloids-Associated Radionuclide Concentrations: Abstraction and Summary

    R. Aguilar

    2003-06-24

    This Model Report describes the analysis and abstractions of the colloids process model for the waste form and engineered barrier system components of the total system performance assessment calculations to be performed with the Total System Performance Assessment-License Application model. Included in this report is a description of (1) the types and concentrations of colloids that could be generated in the waste package from degradation of waste forms and the corrosion of the waste package materials, (2) types and concentrations of colloids produced from the steel components of the repository and their potential role in radionuclide transport, and (3) types and concentrations of colloids present in natural waters in the vicinity of Yucca Mountain. Additionally, attachment/detachment characteristics and mechanisms of colloids anticipated in the repository are addressed and discussed. The abstraction of the process model is intended to capture the most important characteristics of radionuclide-colloid behavior for use in predicting the potential impact of colloid-facilitated radionuclide transport on repository performance.

  20. Fabricating colloidal crystals and construction of ordered nanostructures

    Sun Zhiqiang

    2006-01-01

    Full Text Available AbstractColloidal crystals of polymeric or inorganic microspheres are of extensive interest due to their potential applications in such as sensing, optics, photonic bandgap and surface patterning. The article highlights a set of approaches developed in our group, which are efficient to prepare colloidal crystals with ordered voids, patterned colloidal crystals on non-planar surfaces, heterogeneous colloidal crystals of different building blocks, colloidal crystals composed of non-spherical polyhedrons, and colloidal crystals of non-close-packed colloidal microspheres in particular. The use of these colloidal crystals as templates for different microstructures range from nanoscale to micron-scale is also summarized.

  1. Using Android-Based Educational Game for Learning Colloid Material

    Sari, S.; Anjani, R.; Farida, I.; Ramdhani, M. A.

    2017-09-01

    This research is based on the importance of the development of student’s chemical literacy on Colloid material using Android-based educational game media. Educational game products are developed through research and development design. In the analysis phase, material analysis is performed to generate concept maps, determine chemical literacy indicators, game strategies and set game paths. In the design phase, product packaging is carried out, then validation and feasibility test are performed. Research produces educational game based on Android that has the characteristics that is: Colloid material presented in 12 levels of game in the form of questions and challenges, presents visualization of discourse, images and animation contextually to develop the process of thinking and attitude. Based on the analysis of validation and trial results, the product is considered feasible to use.

  2. Frost Heave in Colloidal Soils

    Peppin, Stephen

    2011-01-01

    We develop a mathematical model of frost heave in colloidal soils. The theory accountsfor heave and consolidation while not requiring a frozen fringe assumption. Two solidificationregimes occur: a compaction regime in which the soil consolidates to accommodate the ice lenses, and a heave regime during which liquid is sucked into the consolidated soil from an external reservoir, and the added volume causes the soil to heave. The ice fraction is found to vary inversely with thefreezing velocity V , while the rate of heave is independent of V , consistent with field and laboratoryobservations. © 2011 Society for Industrial and Applied Mathematics.

  3. CONCH: A Visual Basic program for interactive processing of ion-microprobe analytical data

    Nelson, David R.

    2006-11-01

    A Visual Basic program for flexible, interactive processing of ion-microprobe data acquired for quantitative trace element, 26Al- 26Mg, 53Mn- 53Cr, 60Fe- 60Ni and U-Th-Pb geochronology applications is described. Default but editable run-tables enable software identification of secondary ion species analyzed and for characterization of the standard used. Counts obtained for each species may be displayed in plots against analysis time and edited interactively. Count outliers can be automatically identified via a set of editable count-rejection criteria and displayed for assessment. Standard analyses are distinguished from Unknowns by matching of the analysis label with a string specified in the Set-up dialog, and processed separately. A generalized routine writes background-corrected count rates, ratios and uncertainties, plus weighted means and uncertainties for Standards and Unknowns, to a spreadsheet that may be saved as a text-delimited file. Specialized routines process trace-element concentration, 26Al- 26Mg, 53Mn- 53Cr, 60Fe- 60Ni, and Th-U disequilibrium analysis types, and U-Th-Pb isotopic data obtained for zircon, titanite, perovskite, monazite, xenotime and baddeleyite. Correction to measured Pb-isotopic, Pb/U and Pb/Th ratios for the presence of common Pb may be made using measured 204Pb counts, or the 207Pb or 208Pb counts following subtraction from these of the radiogenic component. Common-Pb corrections may be made automatically, using a (user-specified) common-Pb isotopic composition appropriate for that on the sample surface, or for that incorporated within the mineral at the time of its crystallization, depending on whether the 204Pb count rate determined for the Unknown is substantially higher than the average 204Pb count rate for all session standards. Pb/U inter-element fractionation corrections are determined using an interactive log e-log e plot of common-Pb corrected 206Pb/ 238U ratios against any nominated fractionation-sensitive species pair

  4. Colloid cysts of the third ventricle

    Pina, J.I.; Medrano, J.; Benito, J.L. de; Lasierra, R.; Lopez, S.; Fernandez, J.A.; Villavieja, J.L.

    1994-01-01

    Colloid cysts (CC) are uncommon cystic endo dermal tumors located in the roof of the third ventricle. The clinical features depend on their capacity for obstructing the foramen of Monro, which results in univentricular or biventricular hydrocephalus. We present three cases of colloid cysts of the third ventricle, diagnosed by CT, reviewing their diagnostic, clinical and pathological features

  5. Colloidal assemblies modified by ion irradiation

    Snoeks, E.; Blaaderen, A. van; Dillen, T. van; Kats, C.M. van; Velikov, K.P.; Brongersma, M.L.; Polman, A.

    2001-01-01

    Spherical SiO2 and ZnS colloidal particles show a dramatic anisotropic plastic deformation under 4 MeV Xe ion irradiation, that changes their shape into oblate into oblate ellipsional, with an aspect ratio that can be precisely controlled by the ion fluence. The 290 nm and 1.1 um diameter colloids

  6. The electrostatic interaction between interfacial colloidal particles

    Hurd, A. J.

    1985-11-01

    The electrostatic interaction between charged, colloidal particles trapped at an air-water interface is considered using linearised Poisson-Boltzmann results for point particles. In addition to the expected screened-Coulomb contribution, which decays exponentially, an algebraic dipole-dipole interaction occurs that may account for long-range interactions in interfacial colloidal systems.

  7. Manipulating colloids with charges and electric fields

    Leunissen, M.E.

    2007-01-01

    This thesis presents the results of experimental investigations on a variety of colloidal suspensions. Colloidal particles are at least a hundred times larger than atoms or molecules, but suspended in a liquid they display the same phase behavior, including fluid and crystalline phases. Due to their

  8. Charge collection control using retrograde well tested by proton microprobe irradiation

    Sayama, Hirokazu; Takai, Mikio; Kimura, Hiroshi; Ohno, Yoshikazu; Satoh, Shinichi; Sonoda, Kenichirou; Katani, Norihiko.

    1993-01-01

    Soft error reduction by high-energy ion-implanted layers has been investigated by novel evaluation techniques using high-energy proton microprobes. A retrograde well formed by 160 and 700 keV boron ion implantation could completely suppress soft errors induced by the proton microprobes at 400 keV. The proton-induced current revealed the charge collection efficiency for the retrograde well structure. The collected charge for the retrograde well in the soft-error mapping was proved to be lower than the critical charge of the measured DRAMs(dynamic random-access memories). Complementary use of soft-error mapping and ion-induced-current measurement could clarify well structures immune against soft errors. (author)

  9. Combining Raman Microprobe and XPS to Study High Temperature Oxidation of Metals

    Windisch, Charles F.; Henager, Charles H.; Engelhard, Mark H.; Bennett, Wendy D.

    2011-01-01

    Raman microprobe spectroscopy was applied in studies of high-temperature air oxidation of a ferritic alloy (HT-9) in the absence and presence of zirconia coatings with the objective of evaluating the technique as a way to quickly screen candidate cladding materials and actinide-based mixed oxide fuel mixtures for advanced nuclear reactors. When oxidation was relatively uniform, Raman spectra collected using microscope optics with low spatial resolution were found to be similar to those collected with conventional Raman spectroscopy. These spectra could be used to identify major oxide corrosion products and follow changes in the composition of the oxides due to heating. However, when the oxidation films were comprised of multiple layers of varying composition, or with layers containing metallic phases, techniques with higher depth resolution and sensitivity to zero-valence metals were necessary. The requirements were met by combining Raman microprobe using different optical configurations and x-ray photoelectron spectroscopy.

  10. Colloid transport in saturated porous media: Elimination of attachment efficiency in a new colloid transport model

    Landkamer, Lee L.; Harvey, Ronald W.; Scheibe, Timothy D.; Ryan, Joseph N.

    2013-01-01

    A colloid transport model is introduced that is conceptually simple yet captures the essential features of colloid transport and retention in saturated porous media when colloid retention is dominated by the secondary minimum because an electrostatic barrier inhibits substantial deposition in the primary minimum. This model is based on conventional colloid filtration theory (CFT) but eliminates the empirical concept of attachment efficiency. The colloid deposition rate is computed directly from CFT by assuming all predicted interceptions of colloids by collectors result in at least temporary deposition in the secondary minimum. Also, a new paradigm for colloid re-entrainment based on colloid population heterogeneity is introduced. To accomplish this, the initial colloid population is divided into two fractions. One fraction, by virtue of physiochemical characteristics (e.g., size and charge), will always be re-entrained after capture in a secondary minimum. The remaining fraction of colloids, again as a result of physiochemical characteristics, will be retained “irreversibly” when captured by a secondary minimum. Assuming the dispersion coefficient can be estimated from tracer behavior, this model has only two fitting parameters: (1) the fraction of the initial colloid population that will be retained “irreversibly” upon interception by a secondary minimum, and (2) the rate at which reversibly retained colloids leave the secondary minimum. These two parameters were correlated to the depth of the Derjaguin-Landau-Verwey-Overbeek (DLVO) secondary energy minimum and pore-water velocity, two physical forces that influence colloid transport. Given this correlation, the model serves as a heuristic tool for exploring the influence of physical parameters such as surface potential and fluid velocity on colloid transport.

  11. Bacteria, colloids and organic carbon in groundwater at the Bangombe site in the Oklo area

    Pedersen, K. [ed.

    1996-02-01

    This report describes how microorganisms, colloids and organic matter were sampled from groundwater from six boreholes at the Bangombe site in the Oklo region and subsequently analyzed. For analysis of microorganisms, DNA was extracted from groundwater, amplified and cloned and information available in the ribosomal 16S rRNA gene was used for mapping diversity and distribution of bacteria. Each borehole was dominated by species that did not dominate in any of the other boreholes, a result that probably reflects documented differences in the geochemical environment. Analyses of sampled colloids included SEM and ICP-MS analysis of colloids on membrane and single particle analysis of samples in bottles. The colloid concentration was rather low in these Na-Mg-Ca-HCO{sub 3} type waters. Trace element results show that transition metals and some heavy metals are associated with the colloid phase. Distribution coefficients of trace elements between the water and colloid phases were estimated. For example for uranium, an average of 200 pg/ml was detected in the water, and 40 pg/ml was detected in the colloid phase. A K{sub p} value of 2* 10{sup 6} ml/g was calculated, considering (colloid) = 100 ng/ml. Groundwater samples were collected for analysis of the concentration of organic carbon (TOC), humic substances and metals associated with the humic substances. TOC varied in the range 4-14 mg/l in three boreholes, one borehole had a TOC<1.5 mg/l. The metal speciation study indicated that a large fraction, 8-67% of uranium was bound to the humic matter compared to the fractions of Ca and Fe (<0.4% and 0.02-10%, resp.). 60 refs, 8 figs, 16 tabs.

  12. On the aging and colloid properties of AgI soils

    Despotovicj, R.; Kapetanovicj, J.

    1977-01-01

    A study of the changes of silver iodide sol properties has shown the role of the ageing process in the characterization of the colloid system. An analysis of the critical coagulation concentration changes and of the sedimentation rates with time and electrophoretic mobility of sols has revealed, that sols in the presence of various counter ions do not exhibit strictly equal colloid properties, although counter ions are present at the critical coagulation concentration

  13. Bacteria, colloids and organic carbon in groundwater at the Bangombe site in the Oklo area

    Pedersen, K.

    1996-02-01

    This report describes how microorganisms, colloids and organic matter were sampled from groundwater from six boreholes at the Bangombe site in the Oklo region and subsequently analyzed. For analysis of microorganisms, DNA was extracted from groundwater, amplified and cloned and information available in the ribosomal 16S rRNA gene was used for mapping diversity and distribution of bacteria. Each borehole was dominated by species that did not dominate in any of the other boreholes, a result that probably reflects documented differences in the geochemical environment. Analyses of sampled colloids included SEM and ICP-MS analysis of colloids on membrane and single particle analysis of samples in bottles. The colloid concentration was rather low in these Na-Mg-Ca-HCO 3 type waters. Trace element results show that transition metals and some heavy metals are associated with the colloid phase. Distribution coefficients of trace elements between the water and colloid phases were estimated. For example for uranium, an average of 200 pg/ml was detected in the water, and 40 pg/ml was detected in the colloid phase. A K p value of 2* 10 6 ml/g was calculated, considering (colloid) = 100 ng/ml. Groundwater samples were collected for analysis of the concentration of organic carbon (TOC), humic substances and metals associated with the humic substances. TOC varied in the range 4-14 mg/l in three boreholes, one borehole had a TOC<1.5 mg/l. The metal speciation study indicated that a large fraction, 8-67% of uranium was bound to the humic matter compared to the fractions of Ca and Fe (<0.4% and 0.02-10%, resp.). 60 refs, 8 figs, 16 tabs

  14. Recommendations for plutonium colloid size determination

    Kosiewicz, S.T.

    1984-02-01

    This report presents recommendations for plutonium colloid size determination and summarizes a literature review, discussions with other researchers, and comments from equipment manufacturers. Four techniques suitable for plutonium colloid size characterization are filtration and ultrafiltration, gel permeation chromatography, diffusion methods, and high-pressure liquid chromatography (conditionally). Our findings include the following: (1) Filtration and ultrafiltration should be the first methods used for plutonium colloid size determination because they can provide the most rapid results with the least complicated experimental arrangement. (2) After expertise has been obtained with filtering, gel permeation chromatography should be incorporated into the colloid size determination program. (3) Diffusion methods can be used next. (4) High-pressure liquid chromatography will be suitable after appropriate columns are available. A plutonium colloid size characterization program with filtration/ultrafiltration and gel permeation chromatography has been initiated

  15. Lateral diffusion study of the Pt-Al system using the NAC nuclear microprobe.

    de Waal, H.; Pretorius, R.

    1999-10-01

    In this study a nuclear microprobe (NMP) was used to analyse phase formation during reaction in Pt-Al lateral diffusion couples. Phase identification was done by Rutherford backscattering spectroscopy. These results were compared with phase formation during conventional thin film Pt-Al interactions. The co-existence of multiple phases in lateral diffusion couples is discussed with reference to the effective heat of formation (EHF) model.

  16. Lateral diffusion study of the Pt-Al system using the NAC nuclear microprobe

    Waal, H. de E-mail: dewalla@nac.ac.za; Pretorius, R

    1999-09-02

    In this study a nuclear microprobe (NMP) was used to analyse phase formation during reaction in Pt-Al lateral diffusion couples. Phase identification was done by Rutherford backscattering spectroscopy. These results were compared with phase formation during conventional thin film Pt-Al interactions. The co-existence of multiple phases in lateral diffusion couples is discussed with reference to the effective heat of formation (EHF) model.

  17. Application of the microprobe dredging operation in the treatment of the meibomian gland dysfunction(MGD

    Qing-Qiang Wang

    2014-07-01

    Full Text Available AIM: To evaluate the function of the microprobe dredging technology in the treatment of meibomian gland dysfunction(MGDand to provide fast, efficient, economical and practical method of treatment for meibomian gland dysfunction(MGD. METHODS:The 100μm diameter stainless steel wire was made as the microprobe with the total length of 3cm, which the needle was about 5mm and hand shank was about 2.5cm. Selected 140 cases with dry eyes of meibomian gland dysfunction(MGD, patients were divided into two groups and made them have comparability. Observation group(n=70used microprobe to dredge meibomian gland pipe accompanied with drugs, hot compress and meibomian gland massage treatment. The control group(n=70was given conventional drugs, hot compress and meibomian massage treatment. To compare the tear break-up time(BUT, efficient rate and the cure rate of the two groups after treatment of 1d, 1wk, 2wk, 1 mo, 2mo and 3mo.RESULTS: BUT were significantly prolonged in observation group and control group after treatment, and the observation group improved more obviously; the efficient rate and cure rate of the observation group were significantly higher than that of the control group after 1d, 1wk, 2wk, 1mo, 2mo and 3mo treatment. CONCLUSION:Using microprobe to unclog the meibomian gland tube can provide the fast and efficient, economical and practical treatment for meibomian gland dysfunction(MGD, which can be promoted in the clinical practice.

  18. Distribution of copper and other elements in ryegrass roots, determined with a scanning proton microprobe

    Mazzolini, A.P.; Legge, G.J.F.

    1982-01-01

    A scanning proton microprobe has been used to determine the distribution of Cu and other elements in Wimmera ryegrass roots grown in solution cultures. Cu was found to be localized on or near the surface of the roots in randomly distributed discrete zones. The distribution of Cu was partially correlated with those of Fe, P and Ca and possibly indicates some form of association; co-precipitation in a precipitate of ferric phosphate or hydroxy-oxide is favoured

  19. The study of voids in the AuAl thin-film system using the nuclear microprobe

    de Waal, H. S.; Pretorius, R.; Prozesky, V. M.; Churms, C. L.

    1997-07-01

    A Nuclear Microprobe (NMP) was used to study void formation in thin film gold-aluminium systems. Microprobe Rutherford Backscattering Spectrometry (μRBS) was utilised to effectively obtain a three-dimensional picture of the void structure on the scale of a few nanometers in the depth dimension and a few microns in the in-plane dimension. This study illustrates the usefulness of the NMP in the study of materials and specifically thin-film structures.

  20. The Mars Microprobe Mission: Advanced Micro-Avionics for Exploration Surface

    Blue, Randel

    2000-01-01

    The Mars Microprobe Mission is the second spacecraft developed as part of the New Millennium Program deep space missions. The objective of the Microprobe Project is to demonstrate the applicability of key technologies for future planetary missions by developing two probes for deployment on Mars. The probes are designed with a single stage entry, descent, and landing system and impact the Martian surface at speeds of approximately 200 meters per second. The microprobes are composed of two main sections, a forebody section that penetrates to a depth below the Martian surface of 0.5 to 2 meters, and an aftbody section that remains on the surface. Each probe system consists of a number of advanced technology components developed specifically for this mission. These include a non-erosive aeroshell for entry into. the atmosphere, a set of low temperature batteries to supply probe power, an advanced microcontroller to execute the mission sequence, collect the science data, and react to possible system fault conditions, a telecommunications subsystem implemented on a set of custom integrated circuits, and instruments designed to provide science measurements from above and below the Martian surface. All of the electronic components have been designed and fabricated to withstand the severe impact shock environment and to operate correctly at predicted temperatures below -100 C.

  1. Anomalous columnar order of charged colloidal platelets

    Morales-Anda, L.; Wensink, H. H.; Galindo, A.; Gil-Villegas, A.

    2012-01-01

    Monte Carlo computer simulations are carried out for a model system of like-charged colloidal platelets in the isothermal-isobaric ensemble (NpT). The aim is to elucidate the role of electrostatic interactions on the structure of synthetic clay systems at high particle densities. Short-range repulsions between particles are described by a suitable hard-core model representing a discotic particle. This potential is supplemented with an electrostatic potential based on a Yukawa model for the screened Coulombic potential between infinitely thin disklike macro-ions. The particle aspect-ratio and electrostatic parameters were chosen to mimic an aqueous dispersion of thin, like-charged, rigid colloidal platelets at finite salt concentration. An examination of the fluid phase diagram reveals a marked shift in the isotropic-nematic transition compared to the hard cut-sphere reference system. Several statistical functions, such as the pair correlation function for the center-of-mass coordinates and structure factor, are obtained to characterize the structural organization of the platelets phases. At low salinity and high osmotic pressure we observe anomalous hexagonal columnar structures characterized by interpenetrating columns with a typical intercolumnar distance corresponding to about half of that of a regular columnar phase. Increasing the ionic strength leads to the formation of glassy, disordered structures consisting of compact clusters of platelets stacked into finite-sized columns. These so-called "nematic columnar" structures have been recently observed in systems of charge-stabilized gibbsite platelets. Our findings are corroborated by an analysis of the static structure factor from a simple density functional theory.

  2. Colloids Versus Albumin in Large Volume Paracentesis to Prevent Circulatory Dysfunction: Evidence-based Case Report.

    Widjaja, Felix F; Khairan, Paramita; Kamelia, Telly; Hasan, Irsan

    2016-04-01

    Large volume paracentesis may cause paracentesis induced circulatory dysfunction (PICD). Albumin is recommended to prevent this abnormality. Meanwhile, the price of albumin is too expensive and there should be another alternative that may prevent PICD. This report aimed to compare albumin to colloids in preventing PICD. Search strategy was done using PubMed, Scopus, Proquest, dan Academic Health Complete from EBSCO with keywords of "ascites", "albumin", "colloid", "dextran", "hydroxyethyl starch", "gelatin", and "paracentesis induced circulatory dysfunction". Articles was limited to randomized clinical trial and meta-analysis with clinical question of "In hepatic cirrhotic patient undergone large volume paracentesis, whether colloids were similar to albumin to prevent PICD". We found one meta-analysis and four randomized clinical trials (RCT). A meta analysis showed that albumin was still superior of which odds ratio 0.34 (0.23-0.51). Three RCTs showed the same results and one RCT showed albumin was not superior than colloids. We conclude that colloids could not constitute albumin to prevent PICD, but colloids still have a role in patient who undergone paracentesis less than five liters.

  3. The use of synthetic Zn-/Ni-labeled montmorillonite colloids as a natural bentonite marker

    Huber, F.; Heck, S.; Hoess, P.; Bouby, M.; Schaefer, T.; Truche, L.; Brendle, J.

    2012-01-01

    sorbed onto the Zn-montmorillonite colloids. This can be explained by the difference of the specific surface area with ∼130 m 2 /g for Ni-/Zn-montmorillonite colloids and ∼33 m 2 /g for natural FEBEX colloids, respectively. Based on the conceptual model that the driving force for the radionuclide- colloid desorption process/kinetics and subsequent sorption to the FFM is the excess in surface area offered by the FFM the observed desorption kinetics may be related to the different colloid/FFM surface area ratio. The synthetic Ni- and Zn-montmorillonite colloids investigated in this study behave similar to the natural FEBEX bentonite colloids used in previous studies but possess higher specific surface areas, which in turn influences the radionuclide desorption kinetics. Nonetheless, the synthetic structural labeled montmorillonite colloids appear suitable as a homologue for the natural FEBEX bentonite colloids circumventing the high uncertainties in the previous Al ICP-MS analysis

  4. The LLNL Multi-User Tandem Laboratory PIXE microprobe

    Heikkinen, D.W.; Bench, G.S.; Antolak, A.J.; Morse, D.H.; Pontau, A.E.

    1992-01-01

    We have recently completed the construction of a new ion beamline primarily for particle-induced x-ray emission (PIXE) analysis. This will supplement our current ion microtomography (IMT) material characterization capabilities using accelerator microanalysis. In this paper we describe the PIXE beamline and give some results that characterize the system. We also report the results of some initial experiments

  5. The physics of the colloidal glass transition.

    Hunter, Gary L; Weeks, Eric R

    2012-06-01

    As one increases the concentration of a colloidal suspension, the system exhibits a dramatic increase in viscosity. Beyond a certain concentration, the system is said to be a colloidal glass; structurally, the system resembles a liquid, yet motions within the suspension are slow enough that it can be considered essentially frozen. For several decades, colloids have served as a valuable model system for understanding the glass transition in molecular systems. The spatial and temporal scales involved allow these systems to be studied by a wide variety of experimental techniques. The focus of this review is the current state of understanding of the colloidal glass transition, with an emphasis on experimental observations. A brief introduction is given to important experimental techniques used to study the glass transition in colloids. We describe features of colloidal systems near and in glassy states, including increases in viscosity and relaxation times, dynamical heterogeneity and ageing, among others. We also compare and contrast the glass transition in colloids to that in molecular liquids. Other glassy systems are briefly discussed, as well as recently developed synthesis techniques that will keep these systems rich with interesting physics for years to come.

  6. The physics of the colloidal glass transition

    Hunter, Gary L; Weeks, Eric R

    2012-01-01

    As one increases the concentration of a colloidal suspension, the system exhibits a dramatic increase in viscosity. Beyond a certain concentration, the system is said to be a colloidal glass; structurally, the system resembles a liquid, yet motions within the suspension are slow enough that it can be considered essentially frozen. For several decades, colloids have served as a valuable model system for understanding the glass transition in molecular systems. The spatial and temporal scales involved allow these systems to be studied by a wide variety of experimental techniques. The focus of this review is the current state of understanding of the colloidal glass transition, with an emphasis on experimental observations. A brief introduction is given to important experimental techniques used to study the glass transition in colloids. We describe features of colloidal systems near and in glassy states, including increases in viscosity and relaxation times, dynamical heterogeneity and ageing, among others. We also compare and contrast the glass transition in colloids to that in molecular liquids. Other glassy systems are briefly discussed, as well as recently developed synthesis techniques that will keep these systems rich with interesting physics for years to come. (review article)

  7. Towards conducting inks: Polypyrrole–silver colloids

    Omastová, Mária; Bober, Patrycja; Morávková, Zuzana; Peřinka, Nikola; Kaplanová, Marie; Syrový, Tomáš; Hromádková, Jiřina; Trchová, Miroslava; Stejskal, Jaroslav

    2014-01-01

    Graphical abstract: - Highlights: • Composite colloidal particles combining conducting polymer and metal have been prepared. • Conducting colloids are suitable for printing applications. • Polypyrrole/silver colloids are prepared in a single reaction step. • The conductivity control is discussed and still needs improvement. - Abstract: The oxidation of pyrrole with silver nitrate in the presence of suitable water-soluble polymers yields composite polypyrrole–silver colloids. The polypyrrole–silver nanoparticles stabilized with poly(N-vinylpyrrolidone) have a typical size around 350 nm and polydispersity index 0.20, i.e. a moderate polydispersity in size. Similar results have been obtained with poly(vinyl alcohol) as stabilizer. The effect of stabilizer concentration on the particle size is marginal. In the present study, several types of stabilizers have been tested in addition to currently used poly(N-vinylpyrrolidone). Transmission electron microscopy and optical microscopy revealed the gemini morphology of polypyrrole and silver colloidal nanoparticles and confirmed their size and size-distribution determined by dynamic light scattering. The use of colloidal dispersions provides an efficient tool for the UV–vis and FT Raman spectroscopic characterization of polypyrrole, including the transition between polypyrrole salt and corresponding polypyrrole base. The dispersions were used for the preparation of coatings on polyethylene terephthalate foils, and the properties for polypyrrole–silver composites have been compared with those produced from polypyrrole colloids alone

  8. Influences on physicians' choices of intravenous colloids.

    Miletin, Michael S; Stewart, Thomas E; Norton, Peter G

    2002-07-01

    Controversy over the optimal intravenous fluid for volume resuscitation continues unabated. Our objectives were to characterize the demographics of physicians who prescribe intravenous colloids and determine factors that enter into their decision to choose a colloid. Questionnaire with 61 items. Ten percent ( n = 364) of frequent intravenous fluid prescribers in the province of Ontario, Canada. The response rate was 74%. Colloid use in the past year was reported by 79% of the responding physicians. Important reasons for choosing a colloid included blood loss and manipulation of oncotic pressure. Physicians tended to prefer either albumin or pentastarch, but no important reasons were found for choosing between the two. Albumin with or without crystalloid was preferred in 5/13 scenarios by more than 50% of the respondents, whereas pentastarch was not favored by more than 50% of respondents in any scenario. Physicians practising in critical care areas and teaching hospitals generally preferred pentastarch to albumin. Physicians reporting pentastarch as representing greater than 90% of total colloid use were more likely to have been visited by a drug detailer for pentastarch than those who used less synthetic colloid (54 vs 22%, p distribution. Although albumin appeared to be preferred in more clinical niches, most physicians did not state reasons for choosing between products. Marketing, specialty, location of practice and clinical scenario appear to play significant roles in the utilization of colloid products.

  9. Phosphate binding by natural iron-rich colloids in streams

    Baken, S.; Moens, C.; Griffioen, J.J.; Smolders, E.

    2016-01-01

    Phosphorus (P) in natural waters may be bound to iron (Fe) bearing colloids. However, the natural variation in composition and P binding strength of these colloids remain unclear. We related the composition of "coarse colloids" (colloids in the 0.1-1.2 μm size range) in 47 Belgian streams to the

  10. Cracking in Drying Colloidal Films

    Singh, Karnail B.; Tirumkudulu, Mahesh S.

    2007-05-01

    It has long been known that thick films of colloidal dispersions such as wet clays, paints, and coatings crack under drying. Although capillary stresses generated during drying have been recently identified as the cause for cracking, the existence of a maximum crack-free film thickness that depends on particle size, rigidity, and packing has not been understood. Here, we identify two distinct regimes for crack-free films based on the magnitude of compressive strain at the maximum attainable capillary pressure and show remarkable agreement of measurements with our theory. We anticipate our results to not only form the basis for design of coating formulations for the paints, coatings, and ceramics industry but also assist in the production of crack-free photonic band gap crystals.

  11. Colloidal QDs-polymer nanocomposites

    Gordillo, H.; Suárez, I.; Rodríguez-Cantó, P.; Abargues, R.; García-Calzada, R.; Chyrvony, V.; Albert, S.; Martínez-Pastor, J.

    2012-04-01

    Nanometer-size colloidal semiconductor nanocrystals, or Quantum Dots (NQD), are very prospective active centers because their light emission is highly efficient and temperature-independent. Nanocomposites based on the incorporation of QDs inside a polymer matrix are very promising materials for application in future photonic devices because they combine the properties of QDs with the technological feasibility of polymers. In the present work some basic applications of these new materials have been studied. Firstly, the fabrication of planar and linear waveguides based on the incorporation of CdS, CdSe and CdTe in PMMA and SU-8 are demonstrated. As a result, photoluminescence (PL) of the QDs are coupled to a waveguide mode, being it able to obtain multicolor waveguiding. Secondly, nanocomposite films have been evaluated as photon energy down-shifting converters to improve the efficiency of solar cells.

  12. Carbon Nanomaterials as Antibacterial Colloids

    Michael Maas

    2016-07-01

    Full Text Available Carbon nanomaterials like graphene, carbon nanotubes, fullerenes and the various forms of diamond have attracted great attention for their vast potential regarding applications in electrical engineering and as biomaterials. The study of the antibacterial properties of carbon nanomaterials provides fundamental information on the possible toxicity and environmental impact of these materials. Furthermore, as a result of the increasing prevalence of resistant bacteria strains, the development of novel antibacterial materials is of great importance. This article reviews current research efforts on characterizing the antibacterial activity of carbon nanomaterials from the perspective of colloid and interface science. Building on these fundamental findings, recent functionalization strategies for enhancing the antibacterial effect of carbon nanomaterials are described. The review concludes with a comprehensive outlook that summarizes the most important discoveries and trends regarding antibacterial carbon nanomaterials.

  13. Colloidal CdSe Quantum Rings.

    Fedin, Igor; Talapin, Dmitri V

    2016-08-10

    Semiconductor quantum rings are of great fundamental interest because their non-trivial topology creates novel physical properties. At the same time, toroidal topology is difficult to achieve for colloidal nanocrystals and epitaxially grown semiconductor nanostructures. In this work, we introduce the synthesis of luminescent colloidal CdSe nanorings and nanostructures with double and triple toroidal topology. The nanorings form during controlled etching and rearrangement of two-dimensional nanoplatelets. We discuss a possible mechanism of the transformation of nanoplatelets into nanorings and potential utility of colloidal nanorings for magneto-optical (e.g., Aharonov-Bohm effect) and other applications.

  14. Hydrodynamic interactions in active colloidal crystal microrheology.

    Weeber, R; Harting, J

    2012-11-01

    In dense colloids it is commonly assumed that hydrodynamic interactions do not play a role. However, a found theoretical quantification is often missing. We present computer simulations that are motivated by experiments where a large colloidal particle is dragged through a colloidal crystal. To qualify the influence of long-ranged hydrodynamics, we model the setup by conventional Langevin dynamics simulations and by an improved scheme with limited hydrodynamic interactions. This scheme significantly improves our results and allows to show that hydrodynamics strongly impacts the development of defects, the crystal regeneration, as well as the jamming behavior.

  15. Characterization of natural groundwater colloids at Palmottu

    Vuorinen, U.; Kumpulainen, H.

    1993-01-01

    Characterization of groundwater colloids (size range from 2 nm to 500 nm) in the Palmottu natural analogue (for radioactive waste disposal in Finland) area was continued by sampling another drill hole, 346, at three depths. Results evaluated so far indicate the presence of both organic and inorganic colloids. In terms of chemical composition and morphology, the inorganic colloids differ from those found in previous studies. According to SEM/EDS and STEM/EDS they mostly contain Ca and are spherical in shape. At this stage further characterization and evaluation of results is provisional and does not allow very accurate conclusions to be drawn

  16. Quantum-size colloid metal systems

    Roldugin, V.I.

    2000-01-01

    In the review dealing with quantum-dimensional metallic colloid systems the methods of preparation, electronic, optical and thermodynamic properties of metal nanoparticles and thin films are considered, the effect of ionizing radiation on stability of silver colloid sols and existence of a threshold radiation dose affecting loss of stability being discussed. It is shown that sol stability loss stems from particles charge neutralization due to reduction of sorbed silver ions induced by radiation, which results in destruction of double electric layer on colloid particles boundary [ru

  17. Mapping Metal Elements of Shuangbai Dinosaur Fossil by Synchrotron X-ray Fluorescence Microprobe

    Wang, Y.; Qun, Y.; Ablett, J.

    2008-01-01

    The metal elements mapping of Shuangbai dinosaur fossil, was obtained by synchrotron x-ray fluorescence (SXRF). Eight elements, Ca, Mn, Fe, Cu, Zn, As, Y and Sr were determined. Elements As and Y were detected for the first time in the dinosaur fossil. The data indicated that metal elements are asymmetrical on fossil section. This is different from common minerals. Mapping metals showed that metal element As is few. The dinosaur most likely belongs to natural death. This is different from Zigong dinosaurs which were found dead from poisoning. This method has been used to find that metals Fe and Mn are accrete, and the same is true for Sr and Y. This study indicated that colloid granule Fe and Mn, as well as Sr and Y had opposite electric charges in lithification process of fossils. By this analysis, compound forms can be ascertained. Synchrotron light source x-ray fluorescence is a complementary method that shows mapping of metal elements at the dinosaur fossil, and is rapid, exact and intuitionist. This study shows that dinosaur fossil mineral imaging has a potential in reconstructing the paleoenvironment and ancient geology.

  18. Optimizing colloidal nanocrystals for applications

    Sytnyk, M.

    2015-01-01

    In the scientific literature colloidal nanocrystals are presented as promising materials for multiple applications, in areas covering optoelectronics, photovoltaics, spintronics, catalysis, and bio-medicine. On the marked are, however, only a very limited number of examples found, indeed implementing colloidal nanocrystals. Thus the scope of this thesis was to modify nanocrystals and to tune their properties to fulfill specific demands. While some modifications could be achieved by post synthetic treatments, one key problem of colloidal nanocrystals, hampering there widespread application is the toxicity of their constituents. To develop nanocrystals from non-toxic materials has been a major goal of this thesis as well. Roughly, the results in this thesis could be subdivided into three parts: (i) the development of ion exchange methods to tailor the properties of metallic and metal-oxide based nanocrystal heterostructures, (ii), the synthesis of semiconductor nanocrystals from non-toxic materials, and (iii) the characterization of the nanocrystals by measurements of their morphology, chemical composition, magnetic-, optical-, and electronic properties. In detail, the thesis is subdivided into an introductory chapter, 4 chapters reporting on scientific results, a chapter reporting the used methods, and the conclusions. The 4 chapters devoted to the scientific results correspond to manuscripts, which are either currently in preparation, or have been published in highly ranked scientific journals such as NanoLetters (chapter 2), ACS Nano (chapter 4), or JACS (chapter 5). Thus, these chapters provide also an extra introduction and conclusion section, as well as separate reference lists. Chapter 2 describes a cation exchange process which is used to tune and improve the magnetic properties of different iron-oxide based colloidal nanocrystal-heterostructures. The superparamagnetic blocking temperature, magnetic remanence, and coercivity is tuned by replacing Fe2+ by Co2

  19. Radiation formation of colloidal metallic particles in aqueous systems

    Cuba, Vaclav; Nemec, Mojmir; Gbur, Tomas; John, Jan; Pospisil, Milan; Mucka, Viliam

    2008-01-01

    Full text: Radiation and photochemical methods have been successfully utilized in various steps of nanoparticles preparation. Presented study deals with formation of silver nanoparticles in various aqueous solutions initiated by UV and gamma radiation. Silver nitrate and silver cyanide were used as precursors for radiation and/or photochemical reduction of Ag + ions to the metallic form. Influence of various parameters (dose of radiation, dose rate, exposition time) on nucleation and formation of colloid particles was studied. Attention was also focused on composition of irradiated solution. Aliphatic alcohols were used as scavengers of OH radicals and other oxidizing species. Various organic stabilizers of formed nanoparticles were used, among others ethylenediaminetetraacetic acid, citric acid and polyvinyl alcohol. Irradiation effects were evaluated using UV/Vis absorption spectra in colloid solution, solid phase formed after long-term irradiation was analysed via X-ray structural analysis

  20. Microprobe measurements to determine phase boundaries and diffusion paths in ternary phase diagrams taking a Cu-Ni-Al system as an example

    Rudolph, G.

    1983-01-01

    With the aid of quantitative microprobe tests, diffusion phenomena and phase formation in the ternary CuNiAl system at 600 - 900 0 C were investigated taking as an example the diffusion couple CuNi5Al5-nickel. The diffusion paths in the ternary system are dependent on temperature and assume an S-form in the copper corner of the phase diagram. In the copper corner, the curves swing away from the more rapid component aluminium towards the copper. Due to this non-linear course of the curves, the intermetallic theta-phase of the type (Ni,Cu) 3 Al can be observed as a layer at all temperatures in the boundary zone. At 800 0 C and to a lesser extend at 900 0 C the solubility of α-CuNi40 for aluminium, at around 5 mass-%, is higher than the value given by W.O. Alexander (1938). As far as it is possible with the diffusion couple under analysis, the microprobe measurements taken otherwise conform at 700 and 600 0 C the position of the phase boundary α-(Cu,Ni)/(α+theta)-miscibility gap indicated in W.O. Alexander (1938). (Author)

  1. Colloid-Facilitated Transport of Radionuclides through the Vadose Zone

    Flury, Markus; Harsh, James B.; Zachara, John M.; McCarthy, John F.; Lichtner, Peter C.

    2006-01-01

    This project seeks to improve the basic understanding of the role of colloids in facilitating the transport of contaminants in the vadose zone. We focus on three major thrusts: (1) thermodynamic stability and mobility of colloids formed by reactions of sediments with highly alkaline tank waste solutions, (2) colloid-contaminant interactions, and (3) in-situ colloid mobilization and colloid facilitated contaminant transport occurring in both contaminated and uncontaminated Hanford sediments

  2. Laser Raman microprobe spectroscopy as a diagnostic for the characterisation of diamond and diamond like carbon (DLC) thin films

    Johnston, C.

    1990-10-01

    Invariably when manufacturing an artificial diamond film a mixture of carbon is deposited - tetragonally bonded (diamond), trigonally bonded (graphite) and other allotropic crystalline forms and amorphous carbons. This imposes a need for careful analysis to determine exactly what carbon types constitute the films. Raman spectroscopy is particularly sensitive to crystal and atomic structure and has a number of advantages which make it one of the most useful techniques for interrogating diamond and DLC thin films. Although Raman spectroscopy alone cannot fully characterise the film, it can give more information than simply what particular form of carbon or other impurities are present in the film. It can be used to determine the ratio of sp 2 to sp 3 bonding within the film, and to some extent the crystallite or domain size and the internal stress of the film. The use of laser Raman microprobe spectroscopy as a diagnostic tool in the analysis of diamond and DLC thin films is demonstrated for a variety of carbon films on various substrates and the characterisation of these films is discussed. (author)

  3. Grimsel colloid exercise, an international intercomparison exercise on the sampling and characterization of groundwater colloids

    Degueldre, C.

    1990-01-01

    The Grimsel colloid exercise was an intercomparison exercise which consisted of an in situ sampling phase followed by a colloid characterization step. The goal of this benchmark exercise, which involved 12 laboratories, was to evaluate both sampling and characterization techniques with emphasis on the colloid specific size distribution. The sampling phase took place at the Grimsel test site between 1 and 13 February 1988 and the participating groups produced colloid samples using various methods. This work was carried out within the Community COCO Club, as a component of the Mirage project (second phase)

  4. Synthesis and optical properties of Au decorated colloidal tungsten oxide nanoparticles

    Tahmasebi, Nemat; Mahdavi, Seyed Mohammad

    2015-01-01

    Highlights: • Tungsten oxide nanoparticles were prepared by pulsed laser ablation (PLA). • A very fine metallic Au particles or coating are decorated on the surface of tungsten oxide nanoparticles. • UV–Vis spectroscopy shows an absorption peak at ∼530 nm which is due to SPR effect of gold. • After exposing to hydrogen gas, Au/WO_3 colloidal nanoparticles show excellent gasochromic coloring. - Abstract: In this study, colloidal tungsten oxide nanoparticles were fabricated by pulsed laser ablation of tungsten target using the first harmonic of a Nd:YAG laser (1064 nm) in deionized water. After ablation, a 0.33 g/lit HAuCl_4 aqueous solution was added into as-prepared colloidal nanoparticles. In this process, Au"3"+ ions were reduced to decorate gold metallic state (Au"0) onto colloidal tungsten oxide nanoparticles surface. The morphology and chemical composition of the synthesized nanoparticles were studied by AFM, XRD, TEM and XPS techniques. UV–Vis analysis reveals a distinct absorption peak at ∼530 nm. This peak can be attributed to the surface plasmon resonance (SPR) of Au and confirms formation of gold state. Moreover, X-ray photoelectron spectroscopy reveals that Au ions’ reduction happens after adding HAuCl_4 solution into as-prepared colloidal tungsten oxide nanoparticles. Transmission electron microscope shows that an Au shell has been decorated onto colloidal WO_3 nanoparticles. Noble metal decorated tungsten oxide nanostructure could be an excellent candidate for photocatalysis, gas sensing and gasochromic applications. Finally, the gasochromic behavior of the synthesized samples was investigated by H_2 and O_2 gases bubbling into the produced colloidal Au/WO_3 nanoparticles. Synthesized colloidal nanoparticles show excellent coloration contrast (∼80%) through NIR spectra.

  5. Linear Optical Properties of Gold Colloid

    Jingmin XIA

    2015-11-01

    Full Text Available Gold colloid was prepared by reducing HAuCl4·4H2O with Na3C6H5O7·2H2O. The morphology, size of gold nanoparticles and the optical property of colloid were characterized by transmission electron microscope and UV-Vis spectrophotometer, respectively. It shows that the gold nanoparticles are in the shape of spheres with diameters less than 8 nm, and the surface plasmon resonance absorption peak is located at about 438 nm. As the volume fraction of gold particles increases, the intensity of absorption peak strengthens. The optical property of gold colloid was analyzed by Maxwell-Garnett (MG effective medium theory in the company of Drude dispersion model. The results show that the matrix dielectric constant is a main factor, which influences the optical property of gold colloid.DOI: http://dx.doi.org/10.5755/j01.ms.21.4.9558

  6. Mesoscopic electrohydrodynamic simulations of binary colloidal suspensions

    Rivas, Nicolas; Frijters, Stefan; Pagonabarraga, Ignacio; Harting, Jens

    2018-04-01

    A model is presented for the solution of electrokinetic phenomena of colloidal suspensions in fluid mixtures. We solve the discrete Boltzmann equation with a Bhatnagar-Gross-Krook collision operator using the lattice Boltzmann method to simulate binary fluid flows. Solvent-solvent and solvent-solute interactions are implemented using a pseudopotential model. The Nernst-Planck equation, describing the kinetics of dissolved ion species, is solved using a finite difference discretization based on the link-flux method. The colloids are resolved on the lattice and coupled to the hydrodynamics and electrokinetics through appropriate boundary conditions. We present the first full integration of these three elements. The model is validated by comparing with known analytic solutions of ionic distributions at fluid interfaces, dielectric droplet deformations, and the electrophoretic mobility of colloidal suspensions. Its possibilities are explored by considering various physical systems, such as breakup of charged and neutral droplets and colloidal dynamics at either planar or spherical fluid interfaces.

  7. Suspensions of colloidal particles and aggregates

    Babick, Frank

    2016-01-01

    This book addresses the properties of particles in colloidal suspensions. It has a focus on particle aggregates and the dependency of their physical behaviour on morphological parameters. For this purpose, relevant theories and methodological tools are reviewed and applied to selected examples. The book is divided into four main chapters. The first of them introduces important measurement techniques for the determination of particle size and interfacial properties in colloidal suspensions. A further chapter is devoted to the physico-chemical properties of colloidal particles—highlighting the interfacial phenomena and the corresponding interactions between particles. The book’s central chapter examines the structure-property relations of colloidal aggregates. This comprises concepts to quantify size and structure of aggregates, models and numerical tools for calculating the (light) scattering and hydrodynamic properties of aggregates, and a discussion on van-der-Waals and double layer interactions between ...

  8. Structural properties of dendrimer-colloid mixtures

    Lenz, Dominic A; Blaak, Ronald; Likos, Christos N

    2012-01-01

    We consider binary mixtures of colloidal particles and amphiphilic dendrimers of the second generation by means of Monte Carlo simulations. By using the effective interactions between monomer-resolved dendrimers and colloids, we compare the results of simulations of mixtures stemming from a full monomer-resolved description with the effective two-component description at different densities, composition ratios, colloid diameters and interaction strengths. Additionally, we map the two-component system onto an effective one-component model for the colloids in the presence of the dendrimers. Simulations based on the resulting depletion potentials allow us to extend the comparison to yet another level of coarse graining and to examine under which conditions this two-step approach is valid. In addition, a preliminary outlook into the phase behavior of this system is given. (paper)

  9. Dynamics and Rheology of Soft Colloidal Glasses

    Wen, Yu Ho; Schaefer, Jennifer L.; Archer, Lynden A.

    2015-01-01

    © 2015 American Chemical Society. The linear viscoelastic (LVE) spectrum of a soft colloidal glass is accessed with the aid of a time-concentration superposition (TCS) principle, which unveils the glassy particle dynamics from in-cage rattling

  10. Thermal Jamming of a Colloidal Glass

    Agarwal, Praveen; Srivastava, Samanvaya; Archer, Lynden A.

    2011-01-01

    We investigate the effect of temperature on structure and dynamics of a colloidal glass created by tethering polymers to the surface of inorganic nanoparticles. Contrary to the conventional assumption, an increase in temperature slows down glassy

  11. Mobility of radioactive colloidal particles in groundwater

    Nuttall, H.E.; Long, R.L.

    1993-01-01

    Radiocolloids are a major factor in the rapid migration of radioactive waste in groundwater. For at least two Los Alamos National Laboratory (LANL) sites, researchers have shown that groundwater colloidal particles were responsible for the rapid transport of radioactive waste material in groundwater. On an international scale, a review of reported field observations, laboratory column studies, and carefully collected field samples provides compelling evidence that colloidal particles enhance both radioactive and toxic waste migration. The objective of this project is to understand and predict colloid-contaminant migration through fundamental mathematical models, water sampling, and laboratory experiments and use this information to develop an effective and scientifically based colloid immobilization strategy. The article focuses on solving the suspected radiocolloid transport problems at LANL's Mortandad Canyon site. (author) 6 figs., 5 tabs., 18 refs

  12. Crust formation in drying colloidal suspensions

    Style, R. W.; Peppin, S. S. L.

    2010-01-01

    and the equations of poroelasticity, while the equations of colloid physics govern processes in the suspension. We derive new equations describing this process, including unique boundary conditions coupling the two regions, yielding a moving-boundary model

  13. Colloidal Quantum Dot Photovoltaics: A Path Forward

    Kramer, Illan J.; Sargent, Edward H.

    2011-01-01

    spectrum. CQD materials' ease of processing derives from their synthesis, storage, and processing in solution. Rapid advances have brought colloidal quantum dot photovoltaic solar power conversion efficiencies of 6% in the latest reports. These achievements

  14. Sensitive chemical neutron dosimetry using silver colloids

    Brede, O.; Boes, J.; Hoesselbarth, B.

    1982-01-01

    The radiation-induced formation of silver colloid was checked for its use as a sensitive dosimeter for neutron irradiation. For non-monoenergetic pulsed neutron irradiation in the Dubna IBR-30 reactor, the colloid dosimeter was found to be suitable to indicate the chemical neutron effect, i.e., to determine the sum concentration of the primary particles of water radiolysis: esub(aq)sup(-), OH and H. (author)

  15. Colloidal Silver Not Approved for Treating Animals

    Bagley, Clell V, DVM

    1997-01-01

    FDA has received reports that products containing colloidal silver are being promoted for use in the treatment of mastitis and other serious disease conditions of dairy cattle, as well as for various conditions of companion animals. For example, FDA’s Center for Veterinary Medicine has received reports from the Agency's regional milk specialists and State inspectors that colloidal silver products have been found on some dairy farms. Also, recent articles in some farm newspapers and journals p...

  16. A digital squarer system for positive mass identification on the ARL ion microprobe mass analyser

    Woods, K.N.; Grant, L.D.V.; Rawsthorne, E.D.; Strydom, H.J.; Gries, W.H.

    1984-01-01

    The original analogue squarer for mass scale linearisation in the Ion Microprobe Mass Analyser (IMMA) has been replaced by a programmable digital squarer system which permits reliable mass number identification throughout the tested range 1 to 240. The digital squarer provides signals to both a digital direct reading mass number display and to an X-Y recorder where it provides a linear mass scale correct to within 0,3 mass units. An additional output to a computer can provide binary or BCD mass number data

  17. $ANBA; a rapid, combined data acquisition and correction program for the SEMQ electron microprobe

    McGee, James J.

    1983-01-01

    $ANBA is a program developed for rapid data acquisition and correction on an automated SEMQ electron microprobe. The program provides increased analytical speed and reduced disk read/write operations compared with the manufacturer's software, resulting in a doubling of analytical throughput. In addition, the program provides enhanced analytical features such as averaging, rapid and compact data storage, and on-line plotting. The program is described with design philosophy, flow charts, variable names, a complete program listing, and system requirements. A complete operating example and notes to assist in running the program are included.

  18. New improvements in the characterization of refractory gold in pyrites: an electron microprobe, Moessbauer spectrometry and ion microprobe study

    Marion, P.; Holliger, P.; Boiron, M.C.; Cathelineau, M.; Wagner, F.E.

    1991-01-01

    Studies of pyrites by Moessbauer spectroscopy have shown the presence of gold in a combined state probably inserted within the lattice. In order to enhance detection limits for in-situ quantitative gold analyses, new SIMS investigations have been made thanks to a Resistive Anode Encorder record of the ion emissions, which provides digital images or scans of any part of the analyzed volume. Quantitative analysis of gold have been carried out thanks to 2 MeV ion implantation of gold in reference sulfide crystals, and the bulk composition of a pyrite grain has been determined. Some strong enrichments in gold and arsenic at the crystal margin attest fluctuations in the fluid chemistry and may be interpreted as a final growth zone, which is similar to that observed on arsenopyrite crystals. This multidisciplinary approach constitutes a powerful tool for the investigation of the insertion and distribution of trace elements within crystals, especially gold in sulfides at low contents down to a few ppm. (author)

  19. Determination of the chemical properties of residues retained in individual cloud droplets by XRF microprobe at SPring-8

    Ma, C.-J.; Tohno, S.; Kasahara, M.; Hayakawa, S.

    2004-01-01

    To determine the chemical properties of residue retained in individual cloud droplets is primarily important for the understanding of rainout mechanism and aerosol modification in droplet. The sampling of individual cloud droplets were carried out on the summit of Mt. Taiko located in Tango peninsula, Kyoto prefecture, during Asian dust storm event in March of 2002. XRF microprobe system equipped at SPring-8, BL-37XU was applied to the subsequent quantification analysis of ultra trace elements in residues of individual cloud droplets. It was possible to form the replicas of separated individual cloud droplets on the thin collodion film. The two dimensional XRF maps for the residues in individual cloud droplets were clearly drawn by scanning of micro-beam. Also, XRF spectra of trace elements in residues were well resolved. From the XRF spectra for individual residues, the chemical mixed state of residues could be assumed. The chemical forms of Fe (Fe +++ ) and Zn (Zn + ) could be clearly characterized by their K-edge micro-XANES spectra. By comparison of Z/Si mass ratios of residues in cloud droplets and those of the original sands collected in desert areas in China, the aging of ambient dust particles and their in cloud modification were indirectly assumed

  20. Pb, U, Ti, Hf and Zr distributions in zircons determined by proton microprobe and fission track techniques

    Clark, G.J.; Gulson, B.L.; Cookson, J.A.

    1979-01-01

    A proton microprobe has been used to determine Pb, Tl, Hf and Zr distributions across four single zircon crystals separated from a 'rapakivi' granite. The Pb and Zr data are quantitative: Pb and Tl concentrations were below the measurable limits for determinations in situ by most other techniques. The distribution of U in the same crystals was determined by the fission track technique. Limits on precision of U allow only a qualitative correlation of U and Pb, whereas the Tl and Pb correlation is more exactly determined. Zircons with distinct cores and overgrowths exhibited uniform Zr and Hf concentrations across the crystals, whereas the high U rims and 'inclusions' (domains) also had high Tl and Pb contents. Since almost all the Pb in these zircons is derived by radioactive decay of U, the Tl substitution has paralleled that of U. The results indicate that the high U domains are 'hot spots' rather than a separate mineral phase. The strong positive correlation of U and Pb indicates that there is little U daughter product migration relative to U, within the crystal. However, for the zircon population investigated here, the data are equivocal on the question of whether U addition to zircon crystals is associated with new zircon growth or not. In either case, the heterogeneous U and Pb distributions complicate any interpretations of U-Pb isotopic analysis for such zircon populations. (author)

  1. Experimental evidence of colloids and nanoparticles presence from 25 waste leachates

    Hennebert, Pierre, E-mail: pierre.hennebert@ineris.fr [INERIS – Institut National de l’Environnement Industriel et des Risques, Domaine du Petit Arbois BP33, F-13545 Aix-en-Provence (France); Avellan, Astrid; Yan, Junfang [INERIS – Institut National de l’Environnement Industriel et des Risques, Domaine du Petit Arbois BP33, F-13545 Aix-en-Provence (France); Aguerre-Chariol, Olivier [INERIS, Parc Technologique ALATA, BP No. 2, 60550 Verneuil en Halatte (France)

    2013-09-15

    Highlights: • This work is the first assessment of colloids in waste leachates. • Analytical methods are proposed and discussed. • All the waste have at least one element in colloidal form, and some elements are always colloidal. • Man-made nanoparticles are observed. • It can change the interpretation of leachate elemental concentration. - Abstract: The potential colloids release from a large panel of 25 solid industrial and municipal waste leachates, contaminated soil, contaminated sediments and landfill leachates was studied. Standardized leaching, cascade filtrations and measurement of element concentrations in the microfiltrate (MF) and ultrafiltrate (UF) fraction were used to easily detect colloids potentially released by waste. Precautions against CO{sub 2} capture by alkaline leachates, or bacterial re-growth in leachates from wastes containing organic matter should be taken. Most of the colloidal particles were visible by transmission electron microscopy with energy dispersion spectrometry (TEM–EDS) if their elemental MF concentration is greater than 200 μg l{sup −1}. If the samples are dried during the preparation for microscopy, neoformation of particles can occur from the soluble part of the element. Size distribution analysis measured by photon correlation spectroscopy (PCS) were frequently unvalid, particularly due to polydispersity and/or too low concentrations in the leachates. A low sensitivity device is required, and further improvement is desirable in that field. For some waste leachates, particles had a zeta potential strong enough to remain in suspension. Mn, As, Co, Pb, Sn, Zn had always a colloidal form (MF concentration/UF concentration > 1.5) and total organic carbon (TOC), Fe, P, Ba, Cr, Cu, Ni are partly colloidal for more than half of the samples). Nearly all the micro-pollutants (As, Ba, Co, Cr, Cu, Mo, Ni, Pb, Sb, Sn, V and Zn) were found at least once in colloidal form greater than 100 μg l{sup −1}. In particular

  2. Colloid-Facilitated Transport of Radionuclides Through The Vadose Zone

    Markus Flury; James B. Harsh; John F. McCarthy' Peter C. Lichtner; John M. Zachara

    2007-01-01

    The main purpose of this project was to advance the basic scientific understanding of colloid and colloid-facilitated Cs transport of radionuclides in the vadose zone. We focused our research on the hydrological and geochemical conditions beneath the leaking waste tanks at the USDOE Hanford reservation. Specific objectives were (1) to determine the lability and thermodynamic stability of colloidal materials, which form after reacting Hanford sediments with simulated Hanford Tank Waste, (2) to characterize the interactions between colloidal particles and contaminants, i.e., Cs and Eu, (3) to determine the potential of Hanford sediments for in situ mobilization of colloids, (4) to evaluate colloid-facilitated radionuclide transport through sediments under unsaturated flow, (5) to implement colloid-facilitated contaminant transport mechanisms into a transport model, and (6) to improve conceptual characterization of colloid-contaminant-soil interactions and colloid-facilitated transport for clean-up procedures and long-term risk assessment

  3. Crystallization in polydisperse colloidal suspensions

    Martin, S.; Bryant, G.; Van Megen, W.

    2004-01-01

    Full text: Crystallization and glass formation in colloidal hard spheres has been a very active area of research over the last 15-20 years. For most of this time particle polydispersity has been considered to be a minor concern in these studies. However, over the last few years an increasing number of simulations, theoretical work and experiments have shown that consideration of the polydispersity is critical in understanding these phenomena. In this paper we provide an overview of recent crystallization studies on particles with two very different particle size distributions. These particles exhibit very different equilibrium crystal structures and crystallization kinetics. Based on these measurements and time lapse photographs, we propose a growth mechanism whereby crystallization occurs in conjunction with a local fractionation process near the crystal-fluid interface, which significantly alters the kinetics of crystallite nucleation and growth. This fractionation effect becomes more significant as polydispersity or skewness increases. The unusual crystal structures observed are explained using a schematic model that explains the structure in terms of stacks of planes, which are unregistered due to a high incidence of stacking faults caused by the incorporation of a large number of small particles

  4. Colloid transport in model fracture filling materials

    Wold, S.; Garcia-Garcia, S.; Jonsson, M.

    2010-12-01

    Colloid transport in model fracture filling materials Susanna Wold*, Sandra García-García and Mats Jonsson KTH Chemical Science and Engineering Royal Institute of Technology, SE-100 44 Stockholm, Sweden *Corresponding author: E-mail: wold@kth.se Phone: +46 8 790 6295 In colloid transport in water-bearing fractures, the retardation depends on interactions with the fracture surface by sorption or filtration. These mechanisms are difficult to separate. A rougher surface will give a larger area available for sorption, and also when a particle is physically hindered, it approaches the surface and enables further sorption. Sorption can be explained by electrostatics were the strongest sorption on minerals always is observed at pH below pHpzc (Filby et al., 2008). The adhesion of colloids to mineral surfaces is related to the surface roughness according to a recent study (Darbha et al., 2010). There is a large variation in the characteristics of water-bearing fractures in bedrock in terms of aperture distribution, flow velocity, surface roughness, mineral distributions, presence of fracture filling material, and biological and organic material, which is hard to implement in modeling. The aim of this work was to study the transport of negatively charged colloids in model fracture filling material in relation to flow, porosity, mineral type, colloid size, and surface charge distribution. In addition, the impact on transport of colloids of mixing model fracture filling materials with different retention and immobilization capacities, determined by batch sorption experiments, was investigated. The transport of Na-montmorillonite colloids and well-defined negatively charged latex microspheres of 50, 100, and 200 nm diameter were studied in either columns containing quartz or quartz mixed with biotite. The ionic strength in the solution was exclusively 0.001 and pH 6 or 8.5. The flow rates used were 0.002, 0.03, and 0.6 mL min-1. Sorption of the colloids on the model fracture

  5. Molecular Recognition in the Colloidal World.

    Elacqua, Elizabeth; Zheng, Xiaolong; Shillingford, Cicely; Liu, Mingzhu; Weck, Marcus

    2017-11-21

    Colloidal self-assembly is a bottom-up technique to fabricate functional nanomaterials, with paramount interest stemming from programmable assembly of smaller building blocks into dynamic crystalline domains and photonic materials. Multiple established colloidal platforms feature diverse shapes and bonding interactions, while achieving specific orientations along with short- and long-range order. A major impediment to their universal use as building blocks for predesigned architectures is the inability to precisely dictate and control particle functionalization and concomitant reversible self-assembly. Progress in colloidal self-assembly necessitates the development of strategies that endow bonding specificity and directionality within assemblies. Methodologies that emulate molecular and polymeric three-dimensional (3D) architectures feature elements of covalent bonding, while high-fidelity molecular recognition events have been installed to realize responsive reconfigurable assemblies. The emergence of anisotropic 'colloidal molecules', coupled with the ability to site-specifically decorate particle surfaces with supramolecular recognition motifs, has facilitated the formation of superstructures via directional interactions and shape recognition. In this Account, we describe supramolecular assembly routes to drive colloidal particles into precisely assembled architectures or crystalline lattices via directional noncovalent molecular interactions. The design principles are based upon the fabrication of colloidal particles bearing surface-exposed functional groups that can undergo programmable conjugation to install recognition motifs with high fidelity. Modular and versatile by design, our strategy allows for the introduction and integration of molecular recognition principles into the colloidal world. We define noncovalent molecular interactions as site-specific forces that are predictable (i.e., feature selective and controllable complementary bonding partners

  6. A hard X-ray scanning microprobe for fluorescence imaging and microdiffraction at the Advanced Photon Source

    Cai, L.; Lai, B.; Yun, W.; Ilinski, P.; Legnini, D.; Maser, J.; Rodrigues, W.

    1999-01-01

    A hard x-ray scanning microprobe based on zone plate optics and undulator radiation, in the energy region from 6 to 20 keV, has reached a focal spot size (FWHM) of 0.15 microm (v) x 0.6 microm (h), and a photon flux of 4 x 10 9 photons/sec/0.01%BW. Using a slit 44 meters upstream to create a virtual source, a circular beam spot of 0.15 microm in diameter can be obtained with a photon flux of one order of magnitude less. During fluorescence mapping of trace elements in a single human ovarian cell, the microprobe exhibited an imaging sensitivity for Pt (L a line) of 80 attograms/microm 2 for a count rate of 10 counts per second. The x-ray microprobe has been used to map crystallographic strain and multiquantum well thickness in micro-optoelectronic devices produced with the selective area growth technique

  7. Water evaporation in silica colloidal deposits.

    Peixinho, Jorge; Lefèvre, Grégory; Coudert, François-Xavier; Hurisse, Olivier

    2013-10-15

    The results of an experimental study on the evaporation and boiling of water confined in the pores of deposits made of mono-dispersed silica colloidal micro-spheres are reported. The deposits are studied using scanning electron microscopy, adsorption of nitrogen, and adsorption of water through attenuated total reflection-infrared spectroscopy. The evaporation is characterized using differential scanning calorimetry and thermal gravimetric analysis. Optical microscopy is used to observe the patterns on the deposits after evaporation. When heating at a constant rate and above boiling temperature, the release of water out of the deposits is a two step process. The first step is due to the evaporation and boiling of the surrounding and bulk water and the second is due to the desorption of water from the pores. Additional experiments on the evaporation of water from membranes having cylindrical pores and of heptane from silica deposits suggest that the second step is due to the morphology of the deposits. Copyright © 2013 Elsevier Inc. All rights reserved.

  8. Thermophoretic torque in colloidal particles with mass asymmetry

    Olarte-Plata, Juan; Rubi, J. Miguel; Bresme, Fernando

    2018-05-01

    We investigate the response of anisotropic colloids suspended in a fluid under a thermal field. Using nonequilibrium molecular dynamics computer simulations and nonequilibrium thermodynamics theory, we show that an anisotropic mass distribution inside the colloid rectifies the rotational Brownian motion and the colloids experience transient torques that orient the colloid along the direction of the thermal field. This physical effect gives rise to distinctive changes in the dependence of the Soret coefficient with colloid mass, which features a maximum, unlike the monotonic increase of the thermophoretic force with mass observed in homogeneous colloids.

  9. Colloid Detection in Natural Ground Water from Ruprechtov by Laser-Induced Breakdown Detection

    Hauser, W.; Geckeis, H.; Goetz, R. [FZK - Inst. fuer Nukleare Entsorgung, Ka rlsruhe (Germany)]. e-mail: hauser@ine.fzk.de; Noseck, U. [Gesellschaft fuer Anlagen- und Reaktorsicherheit, D-38122 Braunschweig (Germany); Laciok, A. [Nuclear Research Inst. Rez plc, Waste and Environmental Management Dept., Husinec-Rez, PSC 250 68 (Czech Republic)

    2007-06-15

    A borehole ground water sampling system and a mobile laser-induced breakdown detection (LIBD) equipment for colloid detection combined with a geomonitoring unit have been applied to characterize the natural background colloid concentration in ground waters of the Ruprechtov natural analogue site (Czech Republic). Ground water has been sampled using steel cylinders. To minimize artifacts during ground water sampling the contact to atmospheric oxygen has been excluded. The ground water samples collected in this way are transported to the laboratory where they have been connected to a series of flow-through detection cells. Argon gas is used to press the ground water through these detection cells for colloid analysis (LIBD), pH, Eh, electrical conductivity and oxygen content. After the above mentioned analysis additional samples are taken for chemical analysis by ICP-AES, ICP-MS, IC- and DOC-detection. Our data obtained by in-situ- and laboratory- measurements point out that the natural colloid concentration found at the Ruprechtov site is a strong function of the ground water ionic strength. The LIBD determined natural background colloid concentrations found at Ruprechtov are compared with data of studies performed in Aespoe (Sweden) and Grimsel (Switzerland)

  10. Thermal analysis with expendable cartridge

    Susaki, K.; Landgraf, F.J.G.

    1981-01-01

    The pratical method of thermal analysis with expendable cartridge and some aspects of its use are presented. The results of the method applied to the system Nb-Mn are presented together with data from microprobe. (Author) [pt

  11. Fast probing of glucose and fructose in plant tissues via plasmonic affinity sandwich assay with molecularly-imprinted extraction microprobes.

    Muhammad, Pir; Liu, Jia; Xing, Rongrong; Wen, Yanrong; Wang, Yijia; Liu, Zhen

    2017-12-01

    Determination of specific target compounds in agriculture food and natural plant products is essential for many purposes; however, it is often challenging due to the complexity of the sample matrices. Herein we present a new approach called plasmonic affinity sandwich assay for the facile and rapid probing of glucose and fructose in plant tissues. The approach mainly relies on molecularly imprinted plasmonic extraction microprobes, which were prepared on gold-coated acupuncture needles via boronate affinity controllable oriented surface imprinting with the target monosaccharide as the template molecules. An extraction microprobe was inserted into plant tissues under investigation, which allowed for the specific extraction of glucose or fructose from the tissues. The glucose or fructose molecules extracted on the microprobe were labeled with boronic acid-functionalized Raman-active silver nanoparticles, and thus affinity sandwich complexes were formed on the microprobes. After excess Raman nanotags were washed away, the microprobe was subjected to Raman detection. Upon being irradiated with a laser beam, surface plasmon on the gold-coated microprobes was generated, which further produced plasmon-enhanced Raman scattering of the silver-based nanotags and thereby provided sensitive detection. Apple fruits, which contain abundant glucose and fructose, were used as a model of plant tissues. The approach exhibited high specificity, good sensitivity (limit of detection, 1 μg mL -1 ), and fast speed (the whole procedure required only 20 min). The spatial distribution profiles of glucose and fructose within an apple were investigated by the developed approach. Copyright © 2017 Elsevier B.V. All rights reserved.

  12. X-ray microprobe characterization of materials: the case for undulators on advanced storage rings

    Sparks, C.J. Jr.

    1984-01-01

    The unique properties of X rays offer many advantages over electrons and other charged particles for the microcharacterization of materials. X rays are more efficient in exciting characteristic X-ray fluorescence and produce higher fluorescent signals to backgrounds than obtained with electrons. Detectable limits for X rays are a few parts per billion and are 10 -3 to 10 -5 less than for electrons. Energy deposition in the sample by X rays is 10 -3 to 10 -4 less than for electrons for the same detectable concentration. High-brightness storage rings, especially in the 6 GeV class with undulators, will be approximately 10 3 brighter in the X-ray energy range from 5 keV to 35 keV than existing storage rings and provide for X-ray microprobes that are as bright as the most advanced electron probes. Such X-ray microprobes will produce unprecedented low levels of detection in diffraction, EXAFS, Auger, and photoelectron spectroscopies for both chemical characterization and elemental identification. These major improvements in microcharacterization capabilities will have wide-ranging ramifications not only in materials science but also in physics, chemistry, geochemistry, biology, and medicine

  13. Data smoothing techniques applied to proton microprobe scans of teleost hard parts

    West, I.F.; Gauldie, R.W.; Coote, G.E.

    1992-01-01

    We use a proton microprobe to examine the distribution of elements in otoliths and scales of teleost (bony) fish. The elements of principal interest are calcium and strontium in otoliths and calcium and fluorine in scales. Changes in the distribution of these elements across hard structures may allow inferences about the life histories of fish. Otoliths and scales of interest are up to a centimeter in linear dimension and to reveal the structures of interest up to 200 sampling points are required in each dimension. The time needed to accumulate high X-ray counts at each sampling point can be large, particularly for strontium. To reduce microprobe usage we use data smoothing techniques to reveal changing patterns with modest X-ray count accumulations at individual data points. In this paper we review performance for revealing pattern at modest levels of X-ray count accumulations of a selection of digital filters (moving average smoothers), running median filters, robust locally weighted regression filters and adaptive spline filters. (author)

  14. Millimeter length micromachining using a heavy ion nuclear microprobe with standard magnetic scanning

    Nesprías, F.; Debray, M.E.; Davidson, J.; Kreiner, A.J.

    2013-01-01

    In order to increase the scanning length of our microprobe, we have developed an irradiation procedure suitable for use in any nuclear microprobe, extending at least up to 400% the length of our heavy ion direct writing facility using standard magnetic exploration. Although this method is limited to patterns of a few millimeters in only one direction, it is useful for the manufacture of curved waveguides, optical devices such Mach–Zehnder modulators, directional couplers as well as channels for micro-fluidic applications. As an example, this technique was applied to the fabrication of 3 mm 3D-Mach–Zehnder modulators in lithium niobate with short Y input/output branches and long shaped parallel-capacitor control electrodes. To extend and improve the quality of the machined structures we developed new scanning control software in LabView™ platform. The new code supports an external dose normalization, electrostatic beam blanking and is capable of scanning figures at 16 bit resolution using a National Instruments™ PCI-6731 High-Speed I/O card. A deep and vertical micromachining process using swift 35 Cl ions 70 MeV bombarding energy and direct write patterning was performed on LiNbO 3 , a material which exhibits a strong natural anisotropy to conventional etching. The micromachined structures show the feasibility of this method for manufacturing micro-fluidic channels as well

  15. Millimeter length micromachining using a heavy ion nuclear microprobe with standard magnetic scanning

    Nesprías, F. [Gerencia de Investigación y Aplicaciones, Comisión Nacional de Energía Atómica, Av. Gral Paz 1499 (1650), San Martín, Buenos Aires (Argentina); Debray, M.E., E-mail: debray@tandar.cnea.gov.ar [Gerencia de Investigación y Aplicaciones, Comisión Nacional de Energía Atómica, Av. Gral Paz 1499 (1650), San Martín, Buenos Aires (Argentina); Escuela de Ciencia y Tecnología. Universidad Nacional de Gral. San Martín, M. De Irigoyen 3100 (1650), San Martín, Buenos Aires (Argentina); Davidson, J. [Gerencia de Investigación y Aplicaciones, Comisión Nacional de Energía Atómica, Av. Gral Paz 1499 (1650), San Martín, Buenos Aires (Argentina); CONICET, Avda. Rivadavia 1917 (C1033AAJ), Ciudad Autónoma de Buenos Aires (Argentina); Kreiner, A.J. [Gerencia de Investigación y Aplicaciones, Comisión Nacional de Energía Atómica, Av. Gral Paz 1499 (1650), San Martín, Buenos Aires (Argentina); Escuela de Ciencia y Tecnología. Universidad Nacional de Gral. San Martín, M. De Irigoyen 3100 (1650), San Martín, Buenos Aires (Argentina); CONICET, Avda. Rivadavia 1917 (C1033AAJ), Ciudad Autónoma de Buenos Aires (Argentina); and others

    2013-04-01

    In order to increase the scanning length of our microprobe, we have developed an irradiation procedure suitable for use in any nuclear microprobe, extending at least up to 400% the length of our heavy ion direct writing facility using standard magnetic exploration. Although this method is limited to patterns of a few millimeters in only one direction, it is useful for the manufacture of curved waveguides, optical devices such Mach–Zehnder modulators, directional couplers as well as channels for micro-fluidic applications. As an example, this technique was applied to the fabrication of 3 mm 3D-Mach–Zehnder modulators in lithium niobate with short Y input/output branches and long shaped parallel-capacitor control electrodes. To extend and improve the quality of the machined structures we developed new scanning control software in LabView™ platform. The new code supports an external dose normalization, electrostatic beam blanking and is capable of scanning figures at 16 bit resolution using a National Instruments™ PCI-6731 High-Speed I/O card. A deep and vertical micromachining process using swift {sup 35}Cl ions 70 MeV bombarding energy and direct write patterning was performed on LiNbO{sub 3}, a material which exhibits a strong natural anisotropy to conventional etching. The micromachined structures show the feasibility of this method for manufacturing micro-fluidic channels as well.

  16. Single ion hit detection set-up for the Zagreb ion microprobe

    Smith, R. W.; Karlušić, M.; Jakšić, M.

    2012-04-01

    Irradiation of materials by heavy ions accelerated in MV tandem accelerators may lead to the production of latent ion tracks in many insulators and semiconductors. If irradiation is performed in a high resolution microprobe facility, ion tracks can be ordered by submicrometer positioning precision. However, full control of the ion track positioning can only be achieved by a reliable ion hit detection system that should provide a trigger signal irrespectively of the type and thickness of the material being irradiated. The most useful process that can be utilised for this purpose is emission of secondary electrons from the sample surface that follows the ion impact. The status report of the set-up presented here is based on the use of a channel electron multiplier (CEM) detector mounted on an interchangable sample holder that is inserted into the chamber in a close geometry along with the sample to be irradiated. The set-up has been tested at the Zagreb ion microprobe for different ions and energies, as well as different geometrical arrangements. For energies of heavy ions below 1 MeV/amu, results show that efficient (100%) control of ion impact can be achieved only for ions heavier than silicon. The successful use of the set-up is demonstrated by production of ordered single ion tracks in a polycarbonate film and by monitoring fluence during ion microbeam patterning of Foturan glass.

  17. An extended magnetic quadrupole lens for a high-resolution nuclear microprobe

    Breese, M.B.H. E-mail: m.breese@surrey.ac.uk; Grime, G.W.; Linford, W.; Harold, M

    1999-09-02

    This paper describes the design requirements and initial performance of a new style of magnetic quadrupole lens for use in a high-resolution nuclear microprobe, which is presently being constructed in Oxford. Such a microprobe necessitates the use of a small image distance from the exit face of the final quadrupole lens to the image plane in order to produce a large demagnification. This means that the final lens should be as close to the sample chamber as possible. However, with conventional magnetic quadrupoles the current-carrying coils protrude by a typical distance of 10-20 mm beyond the pole face, thereby significantly limiting the minimum image distance. The approach taken here is to recess the coils into the body of the lens, so that they are almost flush with the pole pieces and lens yoke, enabling an image distance of 55 mm. Three-dimensional magnetic field calculations within this lens structure predict that the field in the extended pole piece 'nose' region is only slightly less than that in the main lens body. Experimental field profiles, measured using a Hall probe, are used to confirm these calculations.

  18. An extended magnetic quadrupole lens for a high-resolution nuclear microprobe

    Breese, M.B.H.; Grime, G.W.; Linford, W.; Harold, M.

    1999-01-01

    This paper describes the design requirements and initial performance of a new style of magnetic quadrupole lens for use in a high-resolution nuclear microprobe, which is presently being constructed in Oxford. Such a microprobe necessitates the use of a small image distance from the exit face of the final quadrupole lens to the image plane in order to produce a large demagnification. This means that the final lens should be as close to the sample chamber as possible. However, with conventional magnetic quadrupoles the current-carrying coils protrude by a typical distance of 10-20 mm beyond the pole face, thereby significantly limiting the minimum image distance. The approach taken here is to recess the coils into the body of the lens, so that they are almost flush with the pole pieces and lens yoke, enabling an image distance of 55 mm. Three-dimensional magnetic field calculations within this lens structure predict that the field in the extended pole piece 'nose' region is only slightly less than that in the main lens body. Experimental field profiles, measured using a Hall probe, are used to confirm these calculations

  19. Study of the toughening mechanisms in bone and biomimetic hydroxyapatite materials using Raman microprobe spectroscopy.

    Pezzotti, Giuseppe; Sakakura, Seiji

    2003-05-01

    A Raman microprobe spectroscopy characterization of microscopic fracture mechanisms is presented for a natural hydroxyapatite material (cortical bovine femur) and two synthetic hydroxyapatite-based materials with biomimetic structures-a hydroxyapatite skeleton interpenetrated with a metallic (silver) or a polymeric (nylon-6) phase. In both the natural and synthetic materials, a conspicuous amount of toughening arose from a microscopic crack-bridging mechanism operated by elasto-plastic stretching of unbroken second-phase ligaments along the crack wake. This mechanism led to a rising R-curve behavior. An additional micromechanism, responsible for stress relaxation at the crack tip, was recognized in the natural bone material and was partly mimicked in the hydroxyapatite/silver composite. This crack-tip mechanism conspicuously enhanced the cortical bone material resistance to fracture initiation. A piezo-spectroscopic technique, based on a microprobe measurement of 980 cm(-1) Raman line of hydroxyapatite, enabled us to quantitatively assess in situ the microscopic stress fields developed during fracture both at the crack tip and along the crack wake. Using the Raman piezo-spectroscopy technique, toughening mechanisms were assessed quantitatively and rationally related to the macroscopic fracture characteristics of hydroxyapatite-based materials. Copyright 2003 Wiley Periodicals, Inc.

  20. Laser induced photoluminescence from Ge{sub 28}Se{sub 60}Sb{sub 12} chalcogenide nano colloids

    Tintu, R., E-mail: tintu_tillanivas@yahoo.co.in [School of Pure and Applied Physics, Mahatma Gandhi University, Kottayam-686560 (India); Nampoori, V.P.N.; Radhakrishnan, P.; Thomas, Sheenu [International School of Photonics, Cochin University of Science and Technology, Cochin 689110 (India); Unnikrishnan, N.V. [School of Pure and Applied Physics, Mahatma Gandhi University, Kottayam-686560 (India)

    2013-04-01

    We report the observation of two-photon induced photoluminescence from Ge{sub 28}Se{sub 60}Sb{sub 12} nano colloid solutions using frequency doubled Nd:YAG laser. Quadratic emission intensity dependence verifies the two photon absorption for the observed luminescence at an excitation of 532 nm. The optical band gap of the material is found to be tunable depending on the cluster size of the nano colloids. The cluster formation and the dependence of the cluster size with concentration were confirmed by the SEM analysis. Confocal imaging was done to confirm the emission from the clusters in the nano colloid solutions.

  1. Depth Probing Soft X-ray Microprobe (DPSXRM) for High Resolution Probing of Earth's Microstructural Samples

    Dikedi, P. N.

    2015-12-01

    The Cambrian explosion; occurrence of landslides in very dry weather conditions; rockslides; dead, shriveled-up and crumbled leaves possessing fossil records with the semblance of well preserved, flat leaves; abundance of trilobite tracks in lower and higher rock layers; and sailing stones are enigmas demanding demystifications. These enigmas could be elucidated when data on soil structure, texture and strength are provided by some device with submicrometre accuracy; for these and other reasons, the design of a Depth Probing Soft X-ray Microprobe (DPSXRM), is being proposed; it is expected to deliver soft X-rays, at spatial resolution, ϛ≥600nm and to probe at the depth of 0.5m in 17s. The microprobe is portable compared to a synchrotron radiation facility (Diamond Light Source has land size of 43,300m2); spatial resolution,ϛ , of the DPSXRM surpasses those of the X-ray Fluorescence microanalysis (10µm), electron microprobe (1-3µm) and ion microprobe (5->30µm); the DPSXRM has allowance for multiple targets. Vanadium and Manganese membranes are proposed owing to respective 4.952KeV VKα1 and 5.899KeV MnKα1 X-rays emitted, which best suits micro-probing of Earth's microstructural samples. Compound systems like the Kirk-Patrick and Baez and Wolter optics, aspheric mirrors like elliptical and parabolic optics, small apertures and Abbe sine condition are employed to reduce or remove astigmatism, obliquity, comatic and spherical aberrations—leading to good image quality. Results show that 5.899KeV MnKα1 and 4.952KeV VKα1 soft X-rays will travel a distance of 2.75mm to form circular patches of radii 2.2mm and 2.95mm respectively. Zone plate with nth zone radius of 1.5mm must be positioned 1.5mm and 2mm from the electron gun if circular patches must be formed from 4.952KeV VKα1 and 5.899KeV MnKα1 soft X-rays respectively. The focal lengths of 0.25μm≤ƒ≤1.50μm and 0.04μm≤ƒ≤0.2μm covered by 4.952KeV VKα1 and 5.899KeV Mn Kα1 soft X-Rays, will

  2. The bio-PIXE setup on the Debrecen scanning proton microprobe

    Kertesz, Zs.; Szikszai, Z.; Uzonyi, I.; Simon, A.; Kiss, A.Z.

    2004-01-01

    Complete text of publication follows. Besides the ongoing applications in archeometry, geology, material science and atmospheric aerosol study, in recent years the IBA Group in Debrecen has joined several biological and biomedical research projects. Such studies require the knowledge of accurate quantitative elemental concentrations and distributions in organic, inhomogeneous thin samples on a microscopic scale. In most cases, to carry out quantitative investigations on biomedical samples down to the cell level, the combination of proton induced X-ray emission (PIXE), Rutherford backscattering (RBS) spectrometry and scanning transmission ion microscopy (STIM) analytical methods are used simultaneously. STIM provides information on the density and structure of the sample, PIXE measures the concentration of the inorganic major and trace elements, and finally RBS serves to characterize the organic matrix, to determine the beam dose, and sometimes the sample thickness. The drawback of this combined method is that to evaluate the RBS data the hydrogen to carbon ratio in the sample must be known. The setup developed at the Debrecen microprobe facility [1] is based on the combined application of on-axis STIM and simultaneous PIXE-PIXE analytical techniques. In the PIXE-PIXE method the sample matrix is determined directly by measuring X-rays from all elements in the sample including the light elements such as carbon and oxygen, using two Si(Li) X-ray detectors. In this arrangement an ultra thin windowed Si(Li) X-ray detector serves to characterize the matrix by measuring low energy X-ray lines (0.2-9 keV) while a large area Be-windowed detector is used to detect the medium and high energy X-ray lines (>4 keV). In this way elements with atomic number higher than 5 can be detected simultaneously, reducing both radiation damage of the sample and measurement time. In addition, the knowledge of the hydrogen content of the sample is not needed, since it influences the

  3. Sorption behavior of cesium onto bentonite colloid

    Iijima, Kazuki; Masuda, Tsuguya; Tomura, Tsutomu

    2004-01-01

    It is considered that bentonite colloid might be generated from bentonite which will be used as buffer material in geological disposal system, and can facilitate the migration of radionuclides by means of sorption. In order to examine this characteristic, sorption and desorption experiments of Cs onto bentonite colloid were carried out to obtain its distribution coefficient (Kd) and information on the reversibility of its sorption. In addition, particle size distribution and shape of colloid were investigated and their effect on the sorption behavior was discussed. Kds for Cs were around 20 m 3 /kg for sorption and 30 m 3 /kg for desorption, in which sorbed Cs was desorbed by 8.4x10 -4 mol/l of NaCl solution. These values did not show any dependencies on Cs concentration and duration of sorption and desorption. The first 20% of sorbed Cs was desorbed reversibly at least. Most of colloidal particles were larger than 200 nm and TEM micrographs showed they had only several sheets of the clay crystal. Obtained Kds for colloidal bentonite were larger than those for powdered bentonite. This can be caused by difference of competing ions in the solution, characteristics of contained smectite, or sorption site density. (author)

  4. Silver nanoparticle colloids with γ-cyclodextrin: enhanced stability and Gibbs–Marangoni flow

    Amiri, Setareh; Duroux, Laurent; Larsen, Kim Lambertsen, E-mail: kll@bio.aau.dk [Aalborg University, Department of Chemistry and Bioscience (Denmark)

    2015-01-15

    Although cyclodextrins (CD) are effective stabilizers for metal nanoparticle colloids, differences between α-, β- and γ-CD in stabilizing such colloids have not been previously reported. In this study, silver nanoparticles (AgNP) were synthesized using NaBH{sub 4} as reducing agent and cyclodextrins as stabilizers. Long-term stability of AgNP colloids in equilibrium conditions showed no marked differences between CD types. Transmission electron microscopy and quantitative image analysis revealed only marginal differences in particle sizes for CD-AgNP, although statistically significant. CD-AgNP colloids showed dispersed particles with average diameters of 7.3 ± 2.2, 6.3 ± 2.9 and 4.9 ± 1.9 nm for α-, β- and γ-CD, respectively, and with similar ζ-potentials about −25 to −30 mV. AgNP without CD showed bigger and aggregated particles of 15.0 ± 2.0 nm with lower ζ-potentials of about −40 mV. When subjected to centrifugal forces, i.e. non-equilibrium conditions, γ-CD was markedly more efficient than α- and β-CD in stabilizing the colloids. Drying patterns of colloid droplets showed a typical self-pinned coffee ring for all but the colloid stabilized by γ-CD, which showed a pattern resulting from a dominant Gibbs–Marangoni flow inside the drying droplet. Calculations using the Derjaguin, Landau, Verwey and Overbeek (DLVO) theory supported the stabilizing effect of CD in equilibrium conditions; it however did not provide clues for the superior stabilization by γ-CD in conditions of hydrodynamic stress.

  5. Silver nanoparticle colloids with γ-cyclodextrin: enhanced stability and Gibbs–Marangoni flow

    Amiri, Setareh; Duroux, Laurent; Larsen, Kim Lambertsen

    2015-01-01

    Although cyclodextrins (CD) are effective stabilizers for metal nanoparticle colloids, differences between α-, β- and γ-CD in stabilizing such colloids have not been previously reported. In this study, silver nanoparticles (AgNP) were synthesized using NaBH 4 as reducing agent and cyclodextrins as stabilizers. Long-term stability of AgNP colloids in equilibrium conditions showed no marked differences between CD types. Transmission electron microscopy and quantitative image analysis revealed only marginal differences in particle sizes for CD-AgNP, although statistically significant. CD-AgNP colloids showed dispersed particles with average diameters of 7.3 ± 2.2, 6.3 ± 2.9 and 4.9 ± 1.9 nm for α-, β- and γ-CD, respectively, and with similar ζ-potentials about −25 to −30 mV. AgNP without CD showed bigger and aggregated particles of 15.0 ± 2.0 nm with lower ζ-potentials of about −40 mV. When subjected to centrifugal forces, i.e. non-equilibrium conditions, γ-CD was markedly more efficient than α- and β-CD in stabilizing the colloids. Drying patterns of colloid droplets showed a typical self-pinned coffee ring for all but the colloid stabilized by γ-CD, which showed a pattern resulting from a dominant Gibbs–Marangoni flow inside the drying droplet. Calculations using the Derjaguin, Landau, Verwey and Overbeek (DLVO) theory supported the stabilizing effect of CD in equilibrium conditions; it however did not provide clues for the superior stabilization by γ-CD in conditions of hydrodynamic stress

  6. colloidal radiogold in malig at effusio sand early ovaria carcinoma

    the radical treatment of ovarian cancer, particularly in early cases, and that colloidal .... radio-active patient treated with colloidal radiogold hould at all times work .... night nurses would receive the following amounts of stray gamma radiation (in ...

  7. Inorganic passivation and doping control in colloidal quantum dot photovoltaics

    Hoogland, Sjoerd H.; Ip, Alex; Thon, Susanna; Voznyy, Oleksandr; Tang, Jiang; Liu, Huan; Zhitomirsky, David; Debnath, Ratan K.; Levina, Larissa; Rollny, Lisa R.; Fischer, Armin H.; Kemp, Kyle W.; Kramer, Illan J.; Ning, Zhijun; Labelle, André J.; Chou, Kang Wei; Amassian, Aram; Sargent, E. H.

    2012-01-01

    We discuss strategies to reduce midgap trap state densities in colloidal quantum dot films and requirements to control doping type and magnitude. We demonstrate that these improvements result in colloidal quantum dot solar cells with certified 7.0% efficiency.

  8. A general approach for monodisperse colloidal perovskites, Chemistry of Materials

    Demirors, A.F.; Imhof, A.

    2009-01-01

    We describe a novel general method for synthesizing monodisperse colloidal perovskite particles at room temperature by postsynthesis addition of metal hydroxides to amorphous titania colloids. In previous work, we used titania particles to synthesize homogenously mixed silica-titania composite

  9. Development of an x-ray fluorescence microprobe at the National Synchrotron Light Source, Brookhaven National Laboratory: Early results: Comparison with data from other techniques

    Smith, J.V.; Rivers, M.L.; Sutton, S.R.; Jones, K.W.; Hanson, A.L.; Gordon, B.M.

    1986-01-01

    Theoretical predictions for the detection levels in x-ray fluorescence analysis with a synchrotron storage ring are being achieved experimentally at several laboratories. This paper is deliberately restricted to the state of development of the Brookhaven National Laboratory/University of Chicago instruments. Analyses at the parts per million (ppM) level are being made using white light apertured to 20 μm and an energy dispersive system. This system is particularly useful for elements with Z > 20 in materials dominated by elements with Z < 20. Diffraction causes an interference for crystalline materials. Development of a focusing microprobe for tunable monochromatic x-rays and a wavelength dispersive spectrometer (WDS) is delayed by problems in shaping an 8:1 focusing mirror to the required accuracy. Reconnaissance analyses with a wiggler source on the CHESS synchrotron have been made in the K spectrum up to Z = 80

  10. Vector assembly of colloids on monolayer substrates

    Jiang, Lingxiang; Yang, Shenyu; Tsang, Boyce; Tu, Mei; Granick, Steve

    2017-06-01

    The key to spontaneous and directed assembly is to encode the desired assembly information to building blocks in a programmable and efficient way. In computer graphics, raster graphics encodes images on a single-pixel level, conferring fine details at the expense of large file sizes, whereas vector graphics encrypts shape information into vectors that allow small file sizes and operational transformations. Here, we adapt this raster/vector concept to a 2D colloidal system and realize `vector assembly' by manipulating particles on a colloidal monolayer substrate with optical tweezers. In contrast to raster assembly that assigns optical tweezers to each particle, vector assembly requires a minimal number of optical tweezers that allow operations like chain elongation and shortening. This vector approach enables simple uniform particles to form a vast collection of colloidal arenes and colloidenes, the spontaneous dissociation of which is achieved with precision and stage-by-stage complexity by simply removing the optical tweezers.

  11. Manipulating semiconductor colloidal stability through doping.

    Fleharty, Mark E; van Swol, Frank; Petsev, Dimiter N

    2014-10-10

    The interface between a doped semiconductor material and electrolyte solution is of considerable fundamental interest, and is relevant to systems of practical importance. Both adjacent domains contain mobile charges, which respond to potential variations. This is exploited to design electronic and optoelectronic sensors, and other enabling semiconductor colloidal materials. We show that the charge mobility in both phases leads to a new type of interaction between semiconductor colloids suspended in aqueous electrolyte solutions. This interaction is due to the electrostatic response of the semiconductor interior to disturbances in the external field upon the approach of two particles. The electrostatic repulsion between two charged colloids is reduced from the one governed by the charged groups present at the particles surfaces. This type of interaction is unique to semiconductor particles and may have a substantial effect on the suspension dynamics and stability.

  12. Shape-shifting colloids via stimulated dewetting

    Youssef, Mena; Hueckel, Theodore; Yi, Gi-Ra; Sacanna, Stefano

    2016-01-01

    The ability to reconfigure elementary building blocks from one structure to another is key to many biological systems. Bringing the intrinsic adaptability of biological systems to traditional synthetic materials is currently one of the biggest scientific challenges in material engineering. Here we introduce a new design concept for the experimental realization of self-assembling systems with built-in shape-shifting elements. We demonstrate that dewetting forces between an oil phase and solid colloidal substrates can be exploited to engineer shape-shifting particles whose geometry can be changed on demand by a chemical or optical signal. We find this approach to be quite general and applicable to a broad spectrum of materials, including polymers, semiconductors and magnetic materials. This synthetic methodology can be further adopted as a new experimental platform for designing and rapidly prototyping functional colloids, such as reconfigurable micro swimmers, colloidal surfactants and switchable building blocks for self-assembly. PMID:27426418

  13. Colloid and interface chemistry for nanotechnology

    Kralchevsky, Peter; Ravera, Francesca

    2016-01-01

    Colloid and interface science dealt with nanoscale objects for nearly a century before the term nanotechnology was coined. An interdisciplinary field, it bridges the macroscopic world and the small world of atoms and molecules. Colloid and Interface Chemistry for Nanotechnology is a collection of manuscripts reflecting the activities of research teams that have been involved in the networking project Colloid and Interface Chemistry for Nanotechnology (2006-2011), Action D43, the European Science Foundation. The project was a part of the intergovernmental framework for Cooperation in Science and Technology (COST), allowing the coordination of nationally funded research across Europe. With contributions by leading experts, this book covers a wide range of topics. Chapters are grouped into three sections: "Nanoparticle Synthesis and Characterization," "New Experimental Tools and Interpretation," and "Nanocolloidal Dispersions and Interfaces." The topics covered belong to six basic research areas: (1) The synthes...

  14. Analytical phase diagrams for colloids and non-adsorbing polymer.

    Fleer, Gerard J; Tuinier, Remco

    2008-11-04

    We review the free-volume theory (FVT) of Lekkerkerker et al. [Europhys. Lett. 20 (1992) 559] for the phase behavior of colloids in the presence of non-adsorbing polymer and we extend this theory in several aspects: (i) We take the solvent into account as a separate component and show that the natural thermodynamic parameter for the polymer properties is the insertion work Pi(v), where Pi is the osmotic pressure of the (external) polymer solution and v the volume of a colloid particle. (ii) Curvature effects are included along the lines of Aarts et al. [J. Phys.: Condens. Matt. 14 (2002) 7551] but we find accurate simple power laws which simplify the mathematical procedure considerably. (iii) We find analytical forms for the first, second, and third derivatives of the grand potential, needed for the calculation of the colloid chemical potential, the pressure, gas-liquid critical points and the critical endpoint (cep), where the (stable) critical line ends and then coincides with the triple point. This cep determines the boundary condition for a stable liquid. We first apply these modifications to the so-called colloid limit, where the size ratio q(R)=R/a between the radius of gyration R of the polymer and the particle radius a is small. In this limit the binodal polymer concentrations are below overlap: the depletion thickness delta is nearly equal to R, and Pi can be approximated by the ideal (van't Hoff) law Pi=Pi(0)=phi/N, where phi is the polymer volume fraction and N the number of segments per chain. The results are close to those of the original Lekkerkerker theory. However, our analysis enables very simple analytical expressions for the polymer and colloid concentrations in the critical and triple points and along the binodals as a function of q(R). Also the position of the cep is found analytically. In order to make the model applicable to higher size ratio's q(R) (including the so-called protein limit where q(R)>1) further extensions are needed. We

  15. Characterization of magnetic colloids by means of magnetooptics

    Baraban, Larysa; Erbe, Artur; Leiderer, Paul

    2007-01-01

    A new, efficient method for the characterization of magnetic colloids based on the Faraday effect is proposed. According to the main principles of this technique, it is possible to detect the stray magnetic field of the colloidal particles induced inside the magnetooptical layer. The magnetic properties of individual particles can be determined providing measurements in a wide range of magnetic fields. The magnetization curves of capped colloids and paramagnetic colloids were measured by mean...

  16. Active structuring of colloidal armour on liquid drops

    Dommersnes, Paul; Rozynek, Zbigniew; Mikkelsen, Alexander; Castberg, Rene; Kjerstad, Knut; Hersvik, Kjetil; Fossum, Jon Otto

    2013-01-01

    Adsorption and assembly of colloidal particles at the surface of liquid droplets are at the base of particle-stabilized emulsions and templating. Here we report that electrohydrodynamic and electro-rheological effects in leaky-dielectric liquid drops can be used to structure and dynamically control colloidal particle assemblies at drop surfaces, including electric-fieldassisted convective assembly of jammed colloidal ‘ribbons’, electro-rheological colloidal chains confined to a...

  17. Uptake of radiocolloid, (2). Lung uptake of sup(99m)Tc-Sn-colloid during liver scintigraphy

    Takahashi, Y [Showa Univ., Tokyo (Japan). School of Medicine

    1980-10-01

    Forty-one of RI lung accumulation were selected from 1536 cases among liver scintigraphy of sup(99m)Tc-Sn-colloid. The results of analysis of these cases are as follows: 1) The cases of lung accumulation caused by failure of preparing sup(99m)Tc-Sn-colloid were excluded. The lung accumulation in liver scintigraphy was able to be found only in sup(99m)Tc-Sn-colloid with large sized particle. 2) From several facts, it is not considered that sup(99m)Tc-colloid was taken into the lung in form of macroaggregation after injection. 3) The lung accumulation of sup(99m)Tc-colloid was not always detected in the cases with any liver disorder. 4) The great majority of cases with the lung accumulation were malignant tumor, the next was liver cirrhosis. When the patients were in the most severe condition, sup(99m)Tc-colloid was apt to be revealed in the lung. In the cases of children, the marked accumulation of the lung was always observed. 5) The lung accumulation of sup(99m)Tc-Sn-colloid was also observed in many patients with splenomegaly without liver disease. It is not a phenomena from the result of decrease in hepatic blood flow or of portal hypertension, but it may be related with certain immunological change. 6) Most patients with the lung accumulation were in extremely severe condition and their survival was not so good. Therefore, this phenomena could refer to a indicator of poor prognosis. 7) The lung accumulation of RI colloid may be revealed when patients fall into extremely severe stage and pulmonary macrophages are stimulated. Its phenomena would be essentially caused by a mechanism that RI-colloid are phagocyted by pulmonary macrophages.

  18. Elemental distribution and sample integrity comparison of freeze-dried and frozen-hydrated biological tissue samples with nuclear microprobe

    Vavpetič, P., E-mail: primoz.vavpetic@ijs.si [Jožef Stefan Institute, Jamova 39, SI-1000 Ljubljana (Slovenia); Vogel-Mikuš, K. [Biotechnical Faculty, Department of Biology, University of Ljubljana, Jamnikarjeva 101, SI-1000 Ljubljana (Slovenia); Jeromel, L. [Jožef Stefan Institute, Jamova 39, SI-1000 Ljubljana (Slovenia); Ogrinc Potočnik, N. [Jožef Stefan Institute, Jamova 39, SI-1000 Ljubljana (Slovenia); FOM-Institute AMOLF, Science Park 104, 1098 XG Amsterdam (Netherlands); Pongrac, P. [Biotechnical Faculty, Department of Biology, University of Ljubljana, Jamnikarjeva 101, SI-1000 Ljubljana (Slovenia); Department of Plant Physiology, University of Bayreuth, Universitätstr. 30, 95447 Bayreuth (Germany); Drobne, D.; Pipan Tkalec, Ž.; Novak, S.; Kos, M.; Koren, Š.; Regvar, M. [Biotechnical Faculty, Department of Biology, University of Ljubljana, Jamnikarjeva 101, SI-1000 Ljubljana (Slovenia); Pelicon, P. [Jožef Stefan Institute, Jamova 39, SI-1000 Ljubljana (Slovenia)

    2015-04-01

    The analysis of biological samples in frozen-hydrated state with micro-PIXE technique at Jožef Stefan Institute (JSI) nuclear microprobe has matured to a point that enables us to measure and examine frozen tissue samples routinely as a standard research method. Cryotome-cut slice of frozen-hydrated biological sample is mounted between two thin foils and positioned on the sample holder. The temperature of the cold stage in the measuring chamber is kept below 130 K throughout the insertion of the samples and the proton beam exposure. Matrix composition of frozen-hydrated tissue is consisted mostly of ice. Sample deterioration during proton beam exposure is monitored during the experiment, as both Elastic Backscattering Spectrometry (EBS) and Scanning Transmission Ion Microscopy (STIM) in on–off axis geometry are recorded together with the events in two PIXE detectors and backscattered ions from the chopper in a single list-mode file. The aim of this experiment was to determine differences and similarities between two kinds of biological sample preparation techniques for micro-PIXE analysis, namely freeze-drying and frozen-hydrated sample preparation in order to evaluate the improvements in the elemental localisation of the latter technique if any. In the presented work, a standard micro-PIXE configuration for tissue mapping at JSI was used with five detection systems operating in parallel, with proton beam cross section of 1.0 × 1.0 μm{sup 2} and a beam current of 100 pA. The comparison of the resulting elemental distributions measured at the biological tissue prepared in the frozen-hydrated and in the freeze-dried state revealed differences in elemental distribution of particular elements at the cellular level due to the morphology alteration in particular tissue compartments induced either by water removal in the lyophilisation process or by unsatisfactory preparation of samples for cutting and mounting during the shock-freezing phase of sample preparation.

  19. Natural colloids in groundwater from granite and their potential impact on radionuclide transport

    Vilks, P.; Bachinski, D.B.

    1997-03-01

    AECL has submitted an Environmental Impact Statement (EIS) to evaluate the concept of nuclear fuel disposal at depth in crystalline rock of the Canadian Shield. As part of geochemical studies carried out in support of the EIS, the role of natural groundwater colloids (0.001 to 0.45 μm) and suspended particles (>0.45 μm) in radionuclide transport in granite rock has been investigated. This report summarizes the results of investigations carried out in groundwaters from the Whiteshell Research Area (WRA) of southern Manitoba and the Atikokan Research Area (ARA) of northwestern Ontario to determine the concentrations, size distributions, and compositions of natural particles in groundwaters from the Canadian Shield. Particles from groundwater were isolated by ultrafiltration under a nitrogen atmosphere and particle concentrations and size distributions were determined by filtration, and by laser-based particle counting and size analysis. Groundwaters from Canadian Shield granites contain particles in a broad range of sizes, with no one particular size being dominant. Particle compositions include aluminosilicates, Fe oxides, carbonate and organics. Suspended particles are most likely generated by the mobilization of fracture-lining minerals by groundwater flow, while colloids are formed by a combination of precipitation and mobilization of colloidal material from fracture surfaces. The average concentration of 0.01 to 0.45 μm colloids in WRA groundwaters was 1.05 ± 0.14 mg/L. Average colloid concentrations were slightly higher in the more highly fractured ARA, although the highest observed colloid concentration in the ARA was below the 7 mg/L maximum observed in a sample from the WRA. The existence of colloids in the 0.001 to 0.01 μm size range was demonstrated using the results of chemical analysis of particle concentrates and data obtained with the laser-based Ultrafine Particle Size Analyzer (UPA). The WRA groundwaters contain on average about 2.7 mg/L of 0

  20. Dynamics of colloidal particles in ice

    Spannuth, Melissa

    2011-01-01

    We use x-ray photon correlation spectroscopy (XPCS) to probe the dynamics of colloidal particles in polycrystalline ice. During freezing, the dendritic ice morphology and rejection of particles from the ice created regions of high particle density, where some of the colloids were forced into contact and formed disordered aggregates. The particles in these high density regions underwent ballistic motion, with a characteristic velocity that increased with temperature. This ballistic motion is coupled with both stretched and compressed exponential decays of the intensity autocorrelation function. We suggest that this behavior could result from ice grain boundary migration. © 2011 American Institute of Physics.