WorldWideScience

Sample records for collective effective dose

  1. Organ or tissue doses, effective dose and collective effective dose from X-ray diagnosis, in Japan

    International Nuclear Information System (INIS)

    Murayama, Takashi; Nishizawa, Kanae; Noda, Yutaka; Kumamoto, Yoshikazu; Iwai, Kazuo.

    1996-01-01

    Effective doses and collective effective doses from X-ray diagnostic examinations were calculated on the basis of the frequency of examinations estimated by a nationwide survey and the organ or tissue doses experimentally determined. The average organ or tissue doses were determined with thermoluminescence dosimeters put at various sites of organs or tissues in an adult and a child phantom. Effective doses (effective dose equivalents) were calculated as the sum of the weighted equivalent doses in all the organs or tissues of the body. As the examples of results, the effective doses per radiographic examination were approximately 7 mGy for male, and 9 mGy for female angiocardiography, and about 3 mGy for barium meal. Annual collective effective dose from X-ray diagnostic examinations in 1986 were about 104 x 10 3 person Sv from radiography and 118 x 10 3 person Sv from fluoroscopy, with the total of 222 x 10 3 person Sv. (author)

  2. Collective effective dose in Europe from x-ray and nuclear medicine procedures

    International Nuclear Information System (INIS)

    Bly, R.; Jaervinen, H.; Jahnen, A.; Olerud, H.; Vassileva, J.; Vogiatzi, S.

    2015-01-01

    Population doses from radiodiagnostic (X-ray and nuclear medicine) procedures in Europe were estimated based on data collected from 36 European countries. For X-ray procedures in EU and EFTA countries (except Liechtenstein) the collective effective dose is 547 500 man Sv, resulting in a mean effective dose of 1.06 mSv per caput. For all European countries included in the survey the collective effective dose is 605 000 man Sv, resulting in a mean effective dose of 1.05 mSv per caput. For nuclear medicine procedures in EU countries and EFTA (except Liechtenstein) countries the collective effective dose is 30 700 man Sv, resulting in a mean effective dose of 0.06 mSv per caput. For all European countries included in the survey the collective effective dose is 31 100 man Sv, resulting in a mean effective dose of 0.05 mSv per caput. (authors)

  3. Estimated collective effective dose to the population from nuclear medicine examinations in Slovenia

    International Nuclear Information System (INIS)

    Skrk, Damijan; Zontar, Dejan

    2013-01-01

    A national survey of patient exposure from nuclear medicine diagnostic procedures was performed by Slovenian Radiation Protection Administration in order to estimate their contribution to the collective effective dose to the population of Slovenia. A set of 36 examinations with the highest contributions to the collective effective dose was identified. Data about frequencies and average administered activities of radioisotopes used for those examinations were collected from all nuclear medicine departments in Slovenia. A collective effective dose to the population and an effective dose per capita were estimated from the collected data using dose conversion factors. The total collective effective dose to the population from nuclear medicine diagnostic procedures in 2011 was estimated to 102 manSv, giving an effective dose per capita of 0.05 mSv. The comparison of results of this study with studies performed in other countries indicates that the nuclear medicine providers in Slovenia are well aware of the importance of patient protection measures and of optimisation of procedures

  4. Collective effective dose equivalent, population doses and risk estimates from occupational exposures in Japan

    International Nuclear Information System (INIS)

    Maruyama, Takashi; Nishizawa, Kanae; Kumamoto, Yoshikazu; Iwai, Kazuo; Mase, Naomichi.

    1993-01-01

    Collective dose equivalent and population dose from occupational exposures in Japan, 1988 were estimated on the basis of a nationwide survey. The survey was conducted on annual collective dose equivalents by sex, age group and type of radiation work for about 0.21 million workers except for the workers in nuclear power stations. The data on the workers in nuclear power stations were obtained from the official report of the Japan Nuclear Safety Commission. The total number of workers including nuclear power stations was estimated to be about 0.26 million. Radiation works were subdivided as follows: medical works including dental; non-atomic energy industry; research and education; atomic energy industry and nuclear power station. For the determination of effective dose equivalent and population dose, organ or tissue doses were measured with a phantom experiment. The resultant doses were compared with the doses previously calculated using a chord length technique and with data from ICRP publications. The annual collective effective dose equivalent were estimated to be about 21.94 person·Sv for medical workers, 7.73 person·Sv for industrial workers, 0.75 person·Sv for research and educational workers, 2.48 person·Sv for atomic energy industry and 84.4 person ·Sv for workers in nuclear power station. The population doses were calculated to be about 1.07 Sv for genetically significant dose, 0.89 Sv for leukemia significant dose and 0.42 Sv for malignant significant dose. The population risks were estimated using these population doses. (author)

  5. In defence of collective dose

    International Nuclear Information System (INIS)

    Fairlie, I.; Sumner, D.

    2000-01-01

    Recent proposals for a new scheme of radiation protection leave little room for collective dose estimations. This article discusses the history and present use of collective doses for occupational, ALARA, EIS and other purposes with reference to practical industry papers and government reports. The linear no-threshold (LNT) hypothesis suggests that collective doses which consist of very small doses added together should be used. Moral and ethical questions are discussed, particularly the emphasis on individual doses to the exclusion of societal risks, uncertainty over effects into the distant future and hesitation over calculating collective detriments. It is concluded that for moral, practical and legal reasons, collective dose is a valid parameter which should continue to be used. (author)

  6. Estimated collective effective dose to the population from radiological examinations in Slovenia

    Science.gov (United States)

    Zontar, Dejan; Zdesar, Urban; Kuhelj, Dimitrij; Pekarovic, Dean; Skrk, Damijan

    2015-01-01

    Background The aim of the study was to systematically evaluate population exposure from diagnostic and interventional radiological procedures in Slovenia. Methods The study was conducted in scope of the “Dose Datamed 2” project. A standard methodology based on 20 selected radiological procedures was adopted. Frequencies of the procedures were determined via questionnaires that were sent to all providers of radiological procedures while data about patient exposure per procedure were collected from existing databases. Collective effective dose to the population and effective dose per capita were estimated from the collected data (DLP for CT, MGD for mammography and DAP for other procedures) using dose conversion factors. Results The total collective effective dose to the population from radiological in 2011 was estimated to 1300 manSv and an effective dose per capita to 0.6 mSv of which approximately 2/3 are due to CT procedures. Conclusions The first systematic study of population exposure to ionising radiation from radiological procedures in Slovenia was performed. The results show that the exposure in Slovenia is under the European average. It confirmed large contributions of computed tomography and interventional procedures, identifying them as the areas that deserve special attention when it comes to justification and optimisation. PMID:25810709

  7. Trends in examination frequency and collective effective doses from computed tomography (CT) procedures in Sudan

    International Nuclear Information System (INIS)

    Yousif, S. B. I.

    2011-01-01

    This study was carried out to estimate the examination frequency and collective dose to population from CT procedures in Sudan. To calculate the annual collective dose from CT examinations a survey was done at 10 hospitals providing data of examinations frequency per day. The data of effective dose have been obtained from pervious study on effective dose per CT examination in Sudan. Then the annual examination frequency and annual collective effective dose had been calculated and discussed providing that the annual collective effective dose from CT examinations is (1482 man.Sv). The highest percentage examination frequency was for head examination (40%). The highest percentage contribution to the total collective dose from CT examinations was for abdomen examinations (32%). The calculated annual examination frequency and annual collective effective dose had been compared with the results of literature and international studies to evaluate the estimated values. The calculated annual collective dose from CT examinations is much lower comparing with the results presented in the literature. The study offers an insight on the examination frequency and the percentage of the risk from different standard radiographic examination within the country. (Author)

  8. Effective collective dose imparted by a medicine nuclear service to Cordoba and Jaen populations

    International Nuclear Information System (INIS)

    Arias, M.C.; Galvez, M.; Torres, M.

    1997-01-01

    The application of diagnostic techniques in nuclear medicine is ever growing as part of clinical daily routine. Although the diagnostic procedures carry a negligible clinical risk, the introduction of radioactive substances into the patient makes it imperative to determine the effective dose to minimize the stochastic effects to the patient thus establishing the collective dose to the community. The aim of our work is to study the collective effective dose imparted by Nuclear Medicine Service during 1997 to Cordoba and Jaen inhabitants (1 448 988). The nuclear medicine techniques of bone exploration with 11 454 mSv-person (4,6 mSv/exploration) and thyroid scintigraphy with 6181 mSv-person (7,0 mSv /exploration) are the main techniques implicated in the relative contribution to the total annual effective collective dose of 35 901.2 mSv-person

  9. Collective dose IRSN view on its indications and contraindications

    International Nuclear Information System (INIS)

    Supervil, S.

    2002-10-01

    The concept of collective protection appeared in 1959 in the first report of the international commission on Radiological Protection (ICRP). During the course of the next decades, ICRP gave details on the use of collective dose, in particular on its role in the process of optimization of protection. The collective dose, effective and /or equivalent, may be used to assess the dosimetric impact of an activity or a source over a group of people, to assess the number of stochastic effects that could result from the exposure of a group of people. The methods of calculating the collective dose are considered, assessment of the levels of exposure, assessment of the health effects. I.R.S.N. reminds that the collective dose constitutes an indicator of the risk of stochastic effects for example in the field of regulatory dose limits. Consequently, the collective dose cannot in any case constitute an indicator of the deterministic effects. (N.C.)

  10. Concepts of collective dose in radiological protection

    International Nuclear Information System (INIS)

    Lindell, B.

    1985-01-01

    The collective dose (S) is the product of the number of individuals exposed and their average radiation dose. ''Radiation dose'' is usually taken to be the effective dose equivalent (Hsub(E)) as defined by the ICRP. The unit of the collective dose is then the man.sievert (man.Sv). The following four applications of the collective dose are the most common: (a) in the assessment of the highest per caput dose rate in the future from a continued practice which exposes some critical group or the population as a whole to radiation; (b) in the limitation of present radiation sources, if it is believed that additional sources in the future may add to the per caput dose in a population so that it might reach unacceptable levels unless all sources are controlled at an early stage; (c) as an input to justification assessments, indicating the total detriment from a certain practice; and (d) as an input to optimization assessments as the basis for costing detriment in differential cost-benefit analyses of protection arrangements. It is sometimes said that the collective dose is a useful quantity only if the assumption of a non-threshold, linear dose-response relation is valid. This assumption is not always necessary. Applications (a) and (b) are possible without any assumption on the dose-response relationship at very low doses. Only applications (c) and (d) require the assumption of a non-threshold, linear dose-response relation. Some hesitation in using the collective dose originates in distrust in the biological assumptions implied by uses (c) and (d), but also in lack of confidence in the meaningfulness of collective doses that have been derived by adding dose contributions over very long time periods. However, none of the four applications (a) - (d) is by necessity related to extreme time scales. That problem mainly arises in the assessment of radioactive waste repositories

  11. Collective doses: IRSN view on its indications and contraindications

    International Nuclear Information System (INIS)

    Supervil, S.

    2002-01-01

    The concept of collective protection appeared in 1959 in the first report of the International Commission on Radiological Protection (ICRP). During the course of the next decades, ICRP gave details on the use of the collective dose, in particular on its role in the process of optimisation of protection. In 1991, ICRP outlined that the collective dose takes account of the number of people exposed to a source by multiplying the average dose to the exposed group by the number of individuals in the group. At present, the collective dose is currently used by those who practice radiological protection, in a prospective and retrospective way. Its use with respect to the management of the protection of workers scarcely raises any debates. On the other hand, its use to assess the public exposure or to estimate the health effects of exposure to ionizing radiation (workers or population) raises numerous criticisms. Some of these criticisms, relating to ethical nature, underline that the collective does not reflect the inequities among the exposed individuals. Criticisms, scientific in nature, concern the linear-non threshold dose effect relationship hypothesis, which enables the collective dose to be represented in terms of risk of the occurrence of stochastic effects. Other criticisms, of an operational nature, relate to the feasibility and the reliability of some collective dose calculations

  12. Collective dose, conceptual basis and practical applications

    International Nuclear Information System (INIS)

    Bonka, H.

    1985-01-01

    In the ICRP Publications no. 22(1973) and no. 26(1977), the ICRP recommends that the maximum permissible whole-body dose by kept below the dose limits corresponding to the sum of all effective dose equivalents of the persons concerned, i.e. the collective dose. The effective dose equivalent is recommended by the ICRP for use as a new quantity for evaluating the stochastic radiation dose for individual persons. Examples are given by the author explaining cost-benefit analyses according to ICRP recommendations, especially discussing the definition of optimum local dose limits with regard to shielding design in nuclear installations. (DG) [de

  13. Calculation error of collective effective dose of external exposure during works at 'Shelter' object

    International Nuclear Information System (INIS)

    Batij, V.G.; Derengovskij, V.V.; Kochnev, N.A.; Sizov, A.A.

    2001-01-01

    Collective effective dose (CED) error assessment is the most important task for optimal planning of works in the 'Shelter' object conditions. The main components of CED error are as follows: error in transient factor determination from exposition dose to equivalent dose; error in working hours determination in 'Shelter' object conditions; error in determination of dose rate at workplaces; additional CED error introduced by shielding of workplaces

  14. Plain radiography procedures in Sudan: examination frequency and collective dose

    International Nuclear Information System (INIS)

    Musa, B. E. Y.

    2010-12-01

    According to the previous studies diagnostic examinations are the largest man-made source to collective dose (CED) in world. It was observed that, despite of the large number of medical x-ray installations in Sudan and in particular conventional x-ray procedures, studies aimed at estimating collective effective dose in diagnostic radiology were lacking. The purpose of this study was to estimate the annual frequency of plain radiography examinations and to estimate the annual collective effective dose to Sudanese population due to plain radiography examinations, selected by their high frequencies or their relatively high doses delivered to patient. To have an idea about the typical examinations frequencies, data were collected from a sample of ten hospitals in Khartoum. The collected data provided information about the x-ray machine manufacture, year of installation and frequency of some examinations per day. The annual collective doses from all medical examinations to the population are: 441, 166, 630, 544, 276, 525, 30, 9, 12 and 161 man Sv from abdomen AP, chest AP, pelvis, lumbar spine PA, lumbar spain PA, lumbar- sacral joints, Skull AP, Skull LAT, Skull PA and from others examination, respectively. The resulting annual collective effective dose was evaluated 2793 man Sv, with the largest contribution of pelvis and LS examinations and lowest contribution of skull examinations. Collective effective dose resulting from the use of plain radiography examinations in the Sudan is small compared with global results. But that dose not negate the need to conduct radiological surveys in frequent intervals to meet the increase of successive x-ray equipment to try to estimate and reduce the doses of patients and the public. (Author)

  15. Dose-effect curves for electron-beam irradiation of some collection microbial strains

    International Nuclear Information System (INIS)

    Ferdes, O.; Dumitru, E.; Catargiu, L.; Ferdes, M.; Minea, R.; Oproiu, C.; Niculescu, A.

    1994-01-01

    There were electron-beam irradiated some microbial strains of B.subtilis ICA I-60 both in germination and in sporulated forms. The irradiation were performed at the IPTRD's electron accelerator at 6 MeV, and in the dose range between 0.1-5.0 kGy, at different dose-rate varying from 50 Gy/minute to 100 Gy/minute. The dosimetry was carried out by a PTW medical dosemeter. There were established the dose-effect relationships and curves, the inactivation dose (factor) and the optimum domain for electron-beam mutagenesis. There were obtained some mutant strains with 2-3.5 higher biosynthesis potential, which are in the IFC's collection. (Author)

  16. Estimation of Collective Effective Dose Due to Cosmic Ray Exposures to Members of The Public and to Airline Passenger

    International Nuclear Information System (INIS)

    Sayed, N.S.; Salah Eldin, T.; Gomaa, M.A.; El Dosoky, T.M.

    2011-01-01

    Using UNSCEAR 2000 report to United Nation General Assembly and its appendices, Annual collective dose to Egyptian members of the public (75097301). Was estimated to be 252.5 man Sv , hence the average collective effective dose to air line passenger for 10 million is estimated as 25.25 micro Sievert. Furthermore using hypothetical approach for Egyptian passengers who fly locally, regionally and internationally, the collective dose was estimated to be 252.5 man Sv , hence the average average collective effective dose for Egyptian passenger is due to Aviation is 3.36 micro Sievert

  17. Estimation of collective effective dose equivalent from environmental radiation and radioactive materials in Japan. A preliminary study

    International Nuclear Information System (INIS)

    Maruyama, Takashi; Noda, Yutaka; Takeshita, Mitsue; Iwai, Kazuo.

    1994-01-01

    The peaceful uses of nuclear power and radiations have been developed into a stage of practical applications for human life. Radiation causes harmful effects to human beings, although human beings receives a number of invaluable benefits from the nuclear energy and the uses of radiation. In order to examine the optimization of radiation protection in these practices, collective effective dose equivalent from environmental exposures due to natural and artificial radiations have been preliminarily evaluated using most recent data. The resultant collective doses were compared with those from medical and occupational exposures. It is noted that, in Japan, the collective effective dose from environmental radiation sources can be approximately same to that from medical exposure. (author)

  18. Regional Diagnostic Reference Levels and Collective Effective Doses from Computed Tomography (CT) Scanners in India

    International Nuclear Information System (INIS)

    Livingstone, R.S.; Dinakaran, P.M.

    2011-01-01

    Diagnostic examinations performed using computed tomography (CT) are on the increase, and the use of this modality needs to be monitored periodically. The aim of this study was to formulate regional diagnostic reference levels (DRLs) and assess collective effective doses from CT scanners in Tamil Nadu, India. In-site CT dose measurements were performed for 127 CT scanners in Tamil Nadu as a part of the Atomic Energy Regulatory Board (AERB) funded project for a period of two years. Regional DRLs were formulated at third quartile level for three CT protocols such as thorax, abdomen and pelvis and were found to be 557 mGy.cm, 521 mGy.cm and 294 mGy.cm, respectively. The collective effective dose in Tamil Nadu was found to be 14.93 man Sv per day. (author)

  19. Survey of CT practice in Japan and collective effective dose estimation

    International Nuclear Information System (INIS)

    Nishizawa, Kanae; Maruyama, Takashi; Matsumoto, Masaki; Iwai, Kazuo

    2004-01-01

    Computed tomography (CT) has been established as an important diagnostic tool in clinical medicine and has become a major source of medical exposure. A nationwide survey regarding CT examinations was carried out in Japan in 2000. CT units per million people in Japan numbered 87.8. The annual number of examinations was 0.1 million in those 0-14 years old, 3.54 million for those 15 years old and above, and 3.65 million in total. Eighty percent of examinations for those 0-14 years old were examinations of the head, as were 40% for those 15 years old and above. The number of examinations per 1000 population was 290. The collective effective dose was 295 x 10 3 person·Sv, and the effective dose per caput was evaluated as 2.3 mSv. (author)

  20. Collective dose commitments from nuclear power programmes

    International Nuclear Information System (INIS)

    Beninson, D.

    1977-01-01

    The concepts of collective dose and collective dose commitment are discussed, particularly regarding their use to compare the relative importance of the exposure from several radiation sources and to predict future annual doses from a continuing practice. The collective dose commitment contributions from occupational exposure and population exposure due to the different components of the nuclear power fuel cycle are evaluated. A special discussion is devoted to exposures delivered over a very long time by released radionuclides of long half-lives and to the use of the incomplete collective dose commitment. The maximum future annual ''per caput'' doses from present and projected nuclear power programmes are estimated

  1. Should repository release criteria be based on collective dose, release limits, or individual doses?

    International Nuclear Information System (INIS)

    Channell, J.K.; Neill, R.H.

    1999-01-01

    The advantages and disadvantages of using each of 3 alternative methods (collective dose, release limits, and individual dose) as release criteria for determining long-term high level or transuranic waste repository performance of naturally occurring releases or man-made intrusions are evaluated. Each of the alternative approaches have positive aspects and each has uncertainties that require some arbitrary assumptions. A comparison of the numerical results from evaluating the three alternatives at WIPP leads to the conclusion that a collective dose is preferable because it is more site specific and allows consideration of the full effects of human intrusion. The main objection to release limits is they do not use site specific criteria to determine the radiological effect on local and regional populations. Individual dose criteria used and recommended in the United States have ignored doses to drillers and the public from wastes brought to the surface by human intrusion because these doses can be greater than acceptable limits. Also, there is disagreement about defining the location and lifestyle of the individual

  2. Estimation of the collective effective dose to the population from medical X-ray examinations in Finland

    International Nuclear Information System (INIS)

    Tenkanen-Rautakoskia, Petra; Jaervinen, Hannu; Bly, Ritva

    2008-01-01

    The collective effective dose to the population from all X-ray examinations in Finland in 2005 was estimated. The numbers of X-ray examinations were collected by a questionnaire to the health care units (response rate 100 %). The effective doses in plain radiography were calculated using a Monte Carlo based program (PCXMC), as average values for selected health care units. For computed tomography (CT), weighted dose length product (DLP w ) in a standard phantom was measured for routine CT protocols of four body regions, for 80 % of CT scanners including all types. The effective doses were calculated from DPL w values using published conversion factors. For contrast-enhanced radiology and interventional radiology, the effective dose was estimated mainly by using published DAP values and conversion factors for given body regions. About 733 examinations per 1000 inhabitants (excluding dental) were made in 2005, slightly less than in 2000. The proportions of plain radiography, computed tomography, contrast-enhanced radiography and interventional procedures were about 92, 7, 1 and 1 %, respectively. From 2000, the frequencies (number of examinations per 1000 inhabitants) of plain radiography and contrast-enhanced radiography have decreased about 8 and 33 %, respectively, while the frequencies of CT and interventional radiology have increased about 28 and 38 %, respectively. The population dose from all X-ray examinations is about 0.43 mSv per person (in 1997 0.5 mSv). About half of this is caused by CT (in 1997 only 20 %) although the relative number of CT examinations is only 7 %. The contribution by plain radiography is 19 %, interventional radiology 17 %, and contrast-enhanced radiology 14 %. It is concluded that CT examinations are the major source of the population dose, while interventional radiology gives about the same population dose as plain radiography. For plain radiography, body examinations cause the highest effective dose. (author)

  3. The remobilisation of radionuclides from marine sediments: implications for collective dose assessments

    International Nuclear Information System (INIS)

    Nicholson, S.; MacKenzie, J.

    1988-09-01

    A model of the transfer (in either direction) of radioactivity between seawater and the seabed is described. It was developed, in the first instance, for inclusion in marine collective dose assessment codes. A review of radionuclide-sediment interactions with particular emphasis on the remobilisation process is followed by a description of the seabed model, an investigation of the effect of the model on estimates of collective dose, and a discussion of sedimentation in the Irish Sea in the context of radioactive discharges. The inclusion of the seabed model may lead to marked decreases in the collective dose at short integration times for nuclides with a high affinity for sediments. For discharges of such radionuclides into the Irish Sea, remobilisation may lead to a significant increase in collective dose compared with estimates obtained ignoring this phenomenon; and thirdly, remobilisation appears to have little effect on collective doses integrated to infinite time for discharges from three other locations in the UK. It is also shown that inclusion of the seabed model leads to predictions of a high uptake of plutonium by the seabed for Irish Sea discharges without the need for anomalously high sedimentation rates. (author)

  4. Effective doses in paediatric radiology

    International Nuclear Information System (INIS)

    Iacob, Olga; Diaconescu, Cornelia; Roca, Antoaneta

    2001-01-01

    Because of their longer life expectancy, the risk of late manifestations of detrimental radiation effects is greater in children than in adults and, consequently, paediatric radiology gives ground for more concern regarding radiation protection than radiology of adults. The purpose of our study is to assess in terms of effective doses the magnitude of paediatric patient exposure during conventional X-ray examinations, selected for their high frequency or their relatively high doses to the patient. Effective doses have been derived from measurements of dose-area product (DAP) carried out on over 900 patients undergoing X-ray examinations, in five paediatric units. The conversion coefficients for estimating effective doses are those calculated by the NRPB using Monte-Carlo technique on a series of 5 mathematical phantoms representing 0, 1, 5, 10 and 15 year old children. The annual frequency of X-ray examinations necessary for collective dose calculation are those reported in our last national study on medical exposure, conducted in 1995. The annual effective doses from all medical examinations for the average paediatric patient are as follows: 1.05 mSv for 0 year old, 0.98 mSv for 1 year old, 0.53 mSv for 5 year old, 0.65 mSv for 10 year old and 0.70 mSv for 15 year old. The resulting annual collective effective dose was evaluated at 625 man Sv with the largest contribution of pelvis and hip examinations (34%). The annual collective effective associated with paediatric radiology in Romania represent 5% of the annual value resulting from all diagnostic radiology. Examination of the chest is by far the most frequent procedure for children, accounting for about 60 per cent of all annually performed X-ray conventional examinations. Knowledge of real level of patient dose is an essential component of quality assurance programs in paediatric radiology. (authors)

  5. Collective dose to the European Community from nuclear industry effluents discharge in 1978

    CERN Document Server

    Camplin, W C

    1983-01-01

    The results are presented of a study to evaluate the collective dose commitment to the population of the European Community from effluents released by the nuclear industry within the EC in 1978. Airborne and liquid effluent discharge data have been taken from published sources, and computer modelling techniques have been used to predict the transfer of radioactivity through the environment to man. The collective dose commitments due to discharges from each nuclear installation have been evaluated and the comparative significance of individual radionuclides and their pathways to man have been considered. Airborne releases resulted in an estimated collective effective dose equivalent commitment of 95 man Sv, the major part of which is due to carbon-14 from both power stations and reprocessing plants. The collective effective dose equivalent commitment from liquid effluents is estimated to be 408 man Sv, mostly due to caesium-137 and other radionuclides from the Sellafield (formerly Windscale) reprocessing plant...

  6. Collective dose as a performance measure for occupational radiation protection programs: Issues and recommendations

    International Nuclear Information System (INIS)

    Strom, D.J.; Harty, R.; Hickey, E.E.; Martin, J.B.; Peffers, M.S.; Kathren, R.L.

    1998-07-01

    Collective dose is one of the performance measures used at many US Department of Energy (DOE) contractor facilities to quantitatively assess the objectives of the radiation protection program. It can also be used as a management tool to improve the program for keeping worker doses as low as reasonably achievable (ALARA). Collective dose is used here to mean the sum of all total effective dose equivalent values for all workers in a specified group over a specified time. It is often used as a surrogate estimate of radiological risk. In principle, improvements in radiation protection programs and procedures will result in reduction of collective dose, all other things being equal. Within the DOE, most frequently, a single collective dose number, which may or may not be adjusted for workload and other factors, is used as a performance measure for a contractor. The purpose of this report is to evaluate the use of collective dose as a performance measure for ALARA programs at DOE sites

  7. Occupational dose reduction developments and data collected at nuclear power plants

    International Nuclear Information System (INIS)

    Dionne, B.J.; Baum, J.W.

    1984-01-01

    Occupational dose reduction developments and data collected at nuclear power plants have been described. Written descriptions of repetitive high dose jobs, their collective dose equivalent ranges and list of dose reduction techniques will aid in reducing collective dose equivalents from these dose-reduction targets. Knowing which components contribute to high maintenance or repair dose will aid in reducing routine maintenance collective dose equivalents. The radwaste dose reduction improvements will aid in reducing radwaste operations collective dose equivalent and reduce the number of radwaste workers who exceed their administrative dose limits. The identification and rating of managers' and workers' ALARA incentives will provide the basis for recommendations to improve dose reduction incentives. Lastly, the identification and rating of the key components of an ALARA program will aid in the development and coordination of the nuclear station ALARA programs

  8. Estimation of effective collective doses to population of Balti city with health risk assessment by means of medical radiodiagnostic irradiation

    International Nuclear Information System (INIS)

    Chislari, V.

    2009-01-01

    In this work the equivalent of effective collective dose, average annual of radio diagnostic researches in medicine for one habitant Belti city during 2006-2008 and a tendency was exposed to multiplying a dose due to multiplying the number of radiological researches was calculated. As compared to indexes for Republic of Moldova annual equivalent of effective dose is increased in 3 times. A potential risk of a medical radiation makes in 2006 - 7 cases of cancer, in 2007 - 8 cases and in 2009 - 9 cases. (author)

  9. Estimation of the collective dose in the Portuguese population due to medical procedures in 2010

    International Nuclear Information System (INIS)

    Teles, Pedro; Vaz, Pedro; Sousa, M. Carmen de; Paulo, Graciano; Santos, Joana; Pascoal, Ana; Cardoso, Gabriela; Santos, Ana Isabel; Lanca, Isabel; Matela, Nuno; Janeiro, Luis; Sousa, Patrick; Carvoeiras, Pedro; Parafita, Rui; Simaozinho, Paula

    2013-01-01

    In a wide range of medical fields, technological advancements have led to an increase in the average collective dose in national populations worldwide. Periodic estimations of the average collective population dose due to medical exposure is, therefore of utmost importance, and is now mandatory in countries within the European Union (article 12 of EURATOM directive 97/ 43). Presented in this work is a report on the estimation of the collective dose in the Portuguese population due to nuclear medicine diagnostic procedures and the Top 20 diagnostic radiology examinations, which represent the 20 exams that contribute the most to the total collective dose in diagnostic radiology and interventional procedures in Europe. This work involved the collaboration of a multidisciplinary taskforce comprising representatives of all major Portuguese stakeholders (universities, research institutions, public and private health care providers, administrative services of the National Healthcare System, scientific and professional associations and private service providers). This allowed us to gather a comprehensive amount of data necessary for a robust estimation of the collective effective dose to the Portuguese population. The methodology used for data collection and dose estimation was based on European Commission recommendations, as this work was performed in the framework of the European wide Dose Datamed II project. This is the first study estimating the collective dose for the population in Portugal, considering such a wide national coverage and range of procedures and consisting of important baseline reference data. The taskforce intends to continue developing periodic collective dose estimations in the future. The estimated annual average effective dose for the Portuguese population was of 0.080±0.017 mSv caput -1 for nuclear medicine exams and of 0.96±0.68 mSv caput -1 for the Top 20 diagnostic radiology exams. (authors)

  10. Collective dose of egyptian atomic energy workers during the period 1991-1995

    Energy Technology Data Exchange (ETDEWEB)

    Gomaa, M A; Youssef, S K [Reactor Division, and Radiation Protect. Dept., Nuclear Reseach Center Atomic Energy Authority, Cairo (Egypt)

    1997-12-31

    The collective dose to egyptian atomic energy authority workers during the period from 1991 - 1995 were statistically evaluated. The personnel dosimetry in use since 1957 for evaluating external exposure doses was mainly the Harwell blue badge and kodak radiation monitoring film for X and Gamma photons. The calibration sensitivity of the badge system was evaluated under the `AL` and/or `Pb/Sn alloy` filters. The results of calibration showed 15% errors in the predicted values for whole body effective doses. The statistical survey showed that the annual collective dose ranged between 0.83-1.54 man Sv. The annual limit of exposure presented 25-58% of the recommended annual limit by ICRP- 60 (1991). Details of the study will be considered in the text. 4 tabs.

  11. Change of annual collective dose equivalent of radiation workers at KURRI

    International Nuclear Information System (INIS)

    Okamoto, Kenichi

    1994-01-01

    The change of exposure dose equivalent of radiation workers at KURRI (Kyoto University Research Reactor Institute) in the past 30 years is reported together with the operational accomplishments. The reactor achieved criticality on June 24, 1964 and reached the normal power of 1000 kW on August 17 of the same year, and the normal power was elevated to 5000 kW on July 16, 1968 until today. The change of the annual effective dose equivalent, the collective dose equivalent, the average annual dose equivalent and the maximum dose equivalent are indicated in the table and the figure. The chronological table on the activities of the reactor is added. (T.H.)

  12. Nationwide survey of dental radiographic examination and estimation of collective effective dose in Japan, 1999

    International Nuclear Information System (INIS)

    Iwai, Kazuo; Satomi, Chieko; Kawashima, Shoji; Hashimoto, Koji; Nishizawa, Kanae; Maruyama, Takashi

    2005-01-01

    A nationwide survey of dental X-ray examination in Japan was performed in 1999, and the effective exposure dose due to the dental X-ray examination was estimated. In Japan, most dental X-ray equipment are used at a tube voltage of 60 kV and a tube current of 10 mA. Dental film in speed group D is most frequently used for dental X ray examination. Fifty percent or more of dental clinics processed the films automatically. Seventy-five percent of dental clinics performed dental X-ray examinations in a separate X-ray room. The number of dental X-ray examinations in 1999 in Japan was estimated to be 82,301,000 for intra-oral radiography and 12,336,000 for panoramic radiography. The collective effective exposure dose in 1999 was estimated at 905.5 man·Sv, for intra-oral radiography and 128.9 man·Sv for panoramic radiography. (author)

  13. Disaggregation of collective dose-a worked example based on future discharges from the Sellafield nuclear fuel reprocessing site, UK

    International Nuclear Information System (INIS)

    Jones, S R; Lambers, B; Stevens, A

    2004-01-01

    Collective dose has long been advocated as an important measure of the detriment associated with practices that involve the use of radioactivity. Application of collective dose in the context of worker protection is relatively straightforward, whereas its application in the context of discharges to the environment can yield radically different conclusions depending upon the population groups and integration times that are considered. The computer program PC-CREAM98 has been used to provide an indicative disaggregation into individual dose bands of the collective dose due to potential future radioactive discharges from the nuclear fuel reprocessing site at Sellafield in the UK. Two alternative discharge scenarios are considered, which represent a 'stop reprocessing early, minimum discharge' scenario and a 'reprocessing beyond current contracts' scenario. For aerial discharges, collective dose at individual effective dose rates exceeding 0.015 μSv y -1 is only incurred within the UK, and at effective dose rates exceeding 1.5 μSv y -1 is only incurred within about 20 km of Sellafield. The geographical distribution of collective dose from liquid discharges is harder to assess, but it appears that collective dose incurred outside the UK is at levels of individual effective dose rate below 1.5 μSv y -1 , with the majority being incurred at rates of 0.002 μSv y -1 or less. In multi-attribute utility analyses, the view taken on the radiological detriment to be attributed to the two discharge scenarios will depend critically on the weight or monetary value ascribed to collective doses incurred within the differing bands of individual dose rate

  14. Collective doses from airborne discharges by the UK nuclear industry

    International Nuclear Information System (INIS)

    Kelly, G.N.

    1981-01-01

    Small quantities of radionuclides are discharged in airborne effluents during the normal operation of nuclear installations. The dispersion of these nuclides in the atmosphere and their subsequent transfer through various sectors of the environment leads to the irradiation of the population. The collective dose to the UK population from airborne discharges in one particular year, 1978, from UK nuclear installations is estimated. The discharges in that year are typical of those in the recent past. Consideration is given to the contribution made by each type of establishment (eg, nuclear power stations, reprocessing plants) and the nuclides which contribute significantly to the collective dose are identified. The distributions of the collective dose in time and among individuals in the exposed population are important features in determining the significance attached to it and both aspects are discussed. The collective dose can be used as a measure of the health detriment associated with the discharge practices considered and is one of several quantities to be taken into account in assessing them. The collective doses from airborne discharges are finally contrasted with those from other sources of exposure of the population. (author)

  15. Global Collective Dose Commitments from Release of Long-Lived Radionuclides

    DEFF Research Database (Denmark)

    Gjørup, H. L.

    1977-01-01

    The concept of global collective dose commitment as a measure of total detriment from the release of radioactivity to the environment is outlined. Estimates are given of global collective dose commitments resulting from the release of 14C and uranium daughter products from the nuclear fuel cycle...... that the use of global collective dose commitments in differential cost-benefit analysis can lead to questionable results. In differential cost-benefit analysis it is suggested that population exposures should not simply be integrated irrespective of their time of occurrence, but that a certain discount rate...

  16. Evaluation of collective doses on the European scale arising from atmospheric discharges

    International Nuclear Information System (INIS)

    Despres, A.; Le Grand, J.; Bouville, A.; Guezengar, J.-M.

    1980-01-01

    The aim of this work is the calculation of annual collective doses received by the population of the European Community as a result of routine atmospheric releases from a nuclear plant. The annual release is broken down into 12-hour steps and the calculation carried out for each of these steps. Summing the contribution from each step allow: one to calculate the time integrated annual atmospheric concentration in each point of a grid covering Western Europe. The collective doses due to external irradiation and to inhalation are then obtained by superimposing the population distribution over the same area. The computer model comprises the following three steps: Calculation of the trajectories followed by the polluant, derived from the meteorological data; the individual trajectories do not follow a straight line as they are corrected every 6 hours. Calculation of the atmospheric concentrations associated with those trajectories. Calculation of the collective doses from external irradiation and from inhalation, using the population grid. This computer model is applied to hypothetical discharges of 85 Kr, 13 +H1I, and 239 Pu, from the Centre d'Etudes Nucleaires de Saclay for the years 1975 and 1976. The comparison of the results obtained from the three radionuclides allows one to assess the influence of the radioactive half-life and of the dry deposition effects on the collective doses. The results were also compared to those obtained using the usual model in which the pollutant trajectory is a straight line. Finally: the releases were classified according to the wind direction at the point of emission in order to study the variation of the collective dose as a function of that parameter. (H.K.)

  17. Problems arising in the evaluation of collective dose commitment

    International Nuclear Information System (INIS)

    Coulon, R.; Beau, P.

    1979-01-01

    In order to apply the concept of optimization it is necessary to evaluate the collective dose commitment for the population as a whole. This is found by summing the dose commitments for the different population groups involved, including persons occupationally exposed and members of the public both locally and globally. The average dose received by each of these groups can vary considerably: for occupational exposure it is about one order of magnitude below the limits, whereas for the general public it is far below, although certain local groups may be subjected to a much higher exposure than the overall average. The question arises, therefore, whether certain groups should not be weighted differently in order to take into account the heterogeneity of the distribution of exposure. As far as the validity of forecast evaluations is concerned, one may assume that for occupational exposure the dose commitment over the whole period of operation of a facility can be estimated fairly accurately. The overall collective dose commitment for the public is relatively insensitive to local variations in the environment and in the public itself but is strongly dependent on long-term developments which cannot at present be forecast. For the evaluation of dose equivalent to the critical group, local variations are of considerable importance and need to be foreseen, which is not always possible. By taking into account a period which includes the annual maximum collective dose equivalent one can make some of these difficulties less severe. (author)

  18. Biological Effects of Low-Dose Exposure

    CERN Document Server

    Komochkov, M M

    2000-01-01

    On the basis of the two-protection reaction model an analysis of stochastic radiobiological effects of low-dose exposure of different biological objects has been carried out. The stochastic effects are the results published in the last decade: epidemiological studies of human cancer mortality, the yield of thymocyte apoptosis of mice and different types of chromosomal aberrations. The results of the analysis show that as dependent upon the nature of biological object, spontanous effect, exposure conditions and radiation type one or another form dose - effect relationship is realized: downwards concave, near to linear and upwards concave with the effect of hormesis included. This result testifies to the incomplete conformity of studied effects of 1990 ICRP recomendations based on the linear no-threshold hypothesis about dose - effect relationship. Because of this the methodology of radiation risk estimation recomended by ICRP needs more precisian and such quantity as collective dose ought to be classified into...

  19. Cost-effectiveness of reduction of off-site dose

    International Nuclear Information System (INIS)

    McGrath, J.J.; Macphee, R.; Arbeau, N.; Miskin, J.; Scott, C.K.; Winters, E.

    1988-03-01

    Since the early 1970's, nuclear power plants have been designed and operated with a target of not releasing more than one percent of the licensed limits (derived emission limits) in liquid and gaseous effluents. The AECB initiated this study of the cost-effectiveness of the reduction of off-site doses as part of a review to determine if further measures to reduce off-site doses might be reasonably achievable. Atlantic Nuclear has estimated the cost of existing technology options that can be applied for a further reduction of radioactive effluents from future CANDU nuclear power plants. Detritiation, filtration, ion exchange and evaporation are included in the assessment. The costs are presented in 1987 Canadian dollars, and include capital and operating costs for a reference 50 year plant life. Darlington NGS and Point Lepreau NGS are the reference nuclear power plant types and locations. The effect resulting from the hypothetical application of each technology has been calculated as the resulting reduction in world collective radiation dose detriment. The CSA N288.1 procedure was used for local pathway analysis and the global dispersion model developed by the NEA (OECD) group of experts was used for dose calculations. The reduction in the 'collective effective dose equivalent commitment' was assumed to exist for 10,000 years, the expected life-span of solid waste repositories. No attempt was made to model world population dynamics. The collective dose reductions were calculated for a nominal world population of 10 billion persons. The estimated cost and effect of applying the technology options are summarized in a tabular form for input to further consideration of 'reasonably achievable off-site dose levels'

  20. The assessment of the collective dose for China population travelling by water

    International Nuclear Information System (INIS)

    Yue Qingyu; Jiang Ping; Jin Hua

    1992-01-01

    The exposure dose rate at 212 points in six shipping lines of the inshore and inland rivers has been measured and the average natural sources exposure dose rate which may be received by the travellers in each shipping line has got. The assessment of collective dose equivalent for the travellers on the shipping lines and the fishery people on the sea has done. In 1988, the collective dose equivalent from natural sources received by Chinese population travelled on the shipping lines of the inshore and inland rivers was 32.7 man·Sv, and the collective dose equivalent from natural sources received by fishery people on the sea was 265.3 man·Sv. The average dose equivalent rate from natural sources at various stayed point received by people of China is given

  1. The cost of collective dose equivalent

    International Nuclear Information System (INIS)

    Clark, M.J.; Fleishman, A.B.

    1979-01-01

    The successful application of the ALARA principle is dependent on a monetary evaluation of collective dose, so that the costs of control may be directly compared with the costs of detriment. The paper initially reviews the traditional, quantitative methods of valuing human life from which a monetary value of the man-sievert can be derived by subsequent application of risk factors. The political, ethical and economic implications of employing such techniques in radiological protection are noted. An alternative approach to the problem is then outlined, based on estimating the marginal value of a change in risk. At low levels of individual risk this includes only the tangible, economic consequences of detriment from output losses and medical costs. However, as risk levels rise, social costs related to the anxiety associated with radiation-induced health effects are also incorporated and the valuation increases disproportionally. While such valuations are in principle measurable, in the absence of empirical data a risk/detriment cost relationship is proposed, leading to a variable monetary value of the man-sievert which is a function of the per caput dose of a given population sub-group. Application of this methodology will help to ensure that radiological protection resources are spent in areas where they are most required. (author)

  2. Optimization of 64-MDCT urography: effect of dual-phase imaging with furosemide on collecting system opacification and radiation dose.

    Science.gov (United States)

    Portnoy, Orith; Guranda, Larisa; Apter, Sara; Eiss, David; Amitai, Marianne Michal; Konen, Eli

    2011-11-01

    The purpose of this study was to compare opacification of the urinary collecting system and radiation dose associated with three-phase 64-MDCT urographic protocols and those associated with a split-bolus dual-phase protocol including furosemide. Images from 150 CT urographic examinations performed with three scanning protocols were retrospectively evaluated. Group A consisted of 50 sequentially registered patients who underwent a three-phase protocol with saline infusion. Group B consisted of 50 sequentially registered patients who underwent a reduced-radiation three-phase protocol with saline. Group C consisted of 50 sequentially registered patients who underwent a dual-phase split-bolus protocol that included a low-dose furosemide injection. Opacification of the urinary collecting system was evaluated with segmental binary scoring. Contrast artifacts were evaluated, and radiation doses were recorded. Results were compared by analysis of variance. A significant reduction in mean effective radiation dose was found between groups A and B (p < 0.001) and between groups B and C (p < 0.001), resulting in 65% reduction between groups A and C (p < 0.001). This reduction did not significantly affect opacification score in any of the 12 urinary segments (p = 0.079). In addition, dense contrast artifacts overlying the renal parenchyma observed with the three-phase protocols (groups A and B) were avoided with the dual-phase protocol (group C) (p < 0.001). A dual-phase protocol with furosemide injection is the preferable technique for CT urography. In comparison with commonly used three-phase protocols, the dual-phase protocol significantly reduces radiation exposure dose without reduction in image quality.

  3. Collective occupational dose for nuclear reactors of the 2., 3. and 4. generation

    International Nuclear Information System (INIS)

    Guidez, J.; Saturnin, A.

    2016-01-01

    In France during reactor operation the individual occupational doses are collected and recorded according to the law. When you sum up all the individual doses you get the yearly collective dose expressed in Man.Sv/year. This piece of information can be used to make comparisons between various types of reactors and between reactors of the same type. The results show a steady decrease of the collective dose for all types of reactors over the time except for CANDU reactors for which a slight increase of the dose has appeared since the years 1996-1998. The decrease is due to the continuous improvement of reactor operating and to changes in the reactor design. There is also a constant gap over time between the collective dose for a BWR reactor (1.12 Man.Sv/y) and a PWR reactor 0.60 Man.Sv/y), this gap is certainly due to N 16 nuclide that is created in the primary circuit and transported to turbines in the case of a BWR reactor. For sodium-cooled fast reactors (RNR-Na) the collective dose is below 0.40 Man.Sv/y except for the BN-600 reactor. (A.C.)

  4. SU-C-201-03: Ionization Chamber Collection Efficiency in Pulsed Radiation Fields of High Pulse Dose

    Energy Technology Data Exchange (ETDEWEB)

    Gotz, M; Karsch, L [Oncoray - National Center for Radiation Research in Oncology, Faculty of Medicine and University Hospital Carl Gustav Carus, Technische Universitaet Dresden, Helmholtz-Zentrum Dresden - Rossendorf, Dresden (Germany); Pawelke, J [Oncoray - National Center for Radiation Research in Oncology, Faculty of Medicine and University Hospital Carl Gustav Carus, Technische Universitaet Dresden, Helmholtz-Zentrum Dresden - Rossendorf, Dresden (Germany); Helmholtz-Zentrum Dresden - Rossendorf, Dresden (Germany)

    2016-06-15

    Purpose: To investigate the reduction of collection efficiency of ionization chambers (IC) by volume recombination and its correction in pulsed fields of very high pulse dose. Methods: Measurements of the collection efficiency of a plane-parallel advanced Markus IC (PTW 34045, 1mm electrode spacing, 300V nominal voltage) were obtained for collection voltages of 100V and 300V by irradiation with a pulsed electron beam (20MeV) of varied pulse dose up to approximately 600mGy (0.8nC liberated charge). A reference measurement was performed with a Faraday cup behind the chamber. It was calibrated for the liberated charge in the IC by a linear fit of IC measurement to reference measurement at low pulse doses. The results were compared to the commonly used two voltage approximation (TVA) and to established theories for volume recombination, with and without considering a fraction of free electrons. In addition, an equation system describing the charge transport and reactions in the chamber was solved numerically. Results: At 100V collection voltage and moderate pulse doses the established theories accurately predict the observed collection efficiency, but at extreme pulse doses a fraction of free electrons needs to be considered. At 300V the observed collection efficiency deviates distinctly from that predicted by any of the established theories, even at low pulse doses. However, the numeric solution of the equation system is able to reproduce the measured collection efficiency across the entire dose range of both voltages with a single set of parameters. Conclusion: At high electric fields (3000V/cm here) the existing theoretical descriptions of collection efficiency, including the TVA, are inadequate to predict pulse dose dependency. Even at low pulse doses they might underestimate collection efficiency. The presented, more accurate numeric solution, which considers additional effects like electric shielding by the charges, might provide a valuable tool for future

  5. SU-C-201-03: Ionization Chamber Collection Efficiency in Pulsed Radiation Fields of High Pulse Dose

    International Nuclear Information System (INIS)

    Gotz, M; Karsch, L; Pawelke, J

    2016-01-01

    Purpose: To investigate the reduction of collection efficiency of ionization chambers (IC) by volume recombination and its correction in pulsed fields of very high pulse dose. Methods: Measurements of the collection efficiency of a plane-parallel advanced Markus IC (PTW 34045, 1mm electrode spacing, 300V nominal voltage) were obtained for collection voltages of 100V and 300V by irradiation with a pulsed electron beam (20MeV) of varied pulse dose up to approximately 600mGy (0.8nC liberated charge). A reference measurement was performed with a Faraday cup behind the chamber. It was calibrated for the liberated charge in the IC by a linear fit of IC measurement to reference measurement at low pulse doses. The results were compared to the commonly used two voltage approximation (TVA) and to established theories for volume recombination, with and without considering a fraction of free electrons. In addition, an equation system describing the charge transport and reactions in the chamber was solved numerically. Results: At 100V collection voltage and moderate pulse doses the established theories accurately predict the observed collection efficiency, but at extreme pulse doses a fraction of free electrons needs to be considered. At 300V the observed collection efficiency deviates distinctly from that predicted by any of the established theories, even at low pulse doses. However, the numeric solution of the equation system is able to reproduce the measured collection efficiency across the entire dose range of both voltages with a single set of parameters. Conclusion: At high electric fields (3000V/cm here) the existing theoretical descriptions of collection efficiency, including the TVA, are inadequate to predict pulse dose dependency. Even at low pulse doses they might underestimate collection efficiency. The presented, more accurate numeric solution, which considers additional effects like electric shielding by the charges, might provide a valuable tool for future

  6. Dispersal, deposition and collective doses after the Chernobyl disaster.

    Science.gov (United States)

    Fairlie, Ian

    2007-01-01

    This article discusses the dispersal, deposition and collective doses of the radioactive fallout from the Chernobyl accident. It explains that, although Belarus, Ukraine and Russia were heavily contaminated by the Chernobyl fallout, more than half of the fallout was deposited outside these countries, particularly in Western Europe. Indeed, about 40 per cent of the surface area of Europe was contaminated. Collective doses are predicted to result in 30,000 to 60,000 excess cancer deaths throughout the northern hemisphere, mostly in western Europe. The article also estimates that the caesium-137 source term was about a third higher than official figures.

  7. The concept of collective injury and of collective dose commitment

    International Nuclear Information System (INIS)

    Jacobi, W.

    The procedure of optimization based on a cost-benefit-analysis ought to include also costs resulting from injuries to health and environment according to the polluter - pays principle. The implementation of a quantitative optimization analysis in the field of radiation protection, however, seems to be extremely difficult. The expediency and applicability needs careful examination. To develop, or to select appropriate strategies of protection, the concept has to be considered on a long-term basis as something giving the direction for future planning of radiation protection. The term of collective injury and collective dose commitment is of prime importance in this context. In principle the concept can be applied to other noxae, especially to carcinogenic and mutagenic chemicals. (DG) [de

  8. Estimates of effective dose in adult CT examinations

    International Nuclear Information System (INIS)

    Mohamed, Mustafa Awad Elhaj.

    2015-12-01

    The goal of study was to estimate effective dose (E) in adult CT examinations for Toshiba X64 slice using CT. Exp version 2.5 software in Sudan. Using of CT in medical diagnosis delivers radiation doses to patients that are higher than those from other radiological procedures. lack of optimized protocols could be an additional source of increased dose in developing countries. In order to achieve these objectives, data of CT-scanner has been collected from three hospitals ( ANH, ZSH and MMH). Data collected included equipment information and scan parameters for individual patients, who were used to asses. 300 adult patients underwent head, chest, abdomen-pelvis and peivis CT examinations. The CT1_w , CTD1_vol, DLP, patient effective dos and organ doses were estimated, using CT exposure parameters and CT Exp version 2.5 software. A large variation of mean effective dose and organ doses among hospitals was observed for similar CT examinations. These variations largely originated from different CT scanning protocols used in different hospitals and scan length. The mean effective dose in this study in the Brain, PNS, Chest, pulmonary, Abdomen-pelvis, Pelvis, KUB and CTU were 3.2 mSv, 2.6 mSv, 18.9 mSv 17.6 mSv 27.1 mSv, 11.2 mSv, 9.6 mSv and 23.7 mSv respectively, and organ equivalent, doses presented in this study in this study for the eye lens (for head), lungs and thymus ( for chest) , liver, kidney and small intest ( for abdomen t-pelvis), bladder, uterus and gonads ( for pelvis), were 62.9 mSv, 39.5 mSv, 34.1 mSv, 53.9 mSv, 52.6 mSv, 58.1 mSv, 37 mSv, and 34.6 mSv, respectively. These values were mostly comparable to and slightly higher than the values of effective doses reported from similar studies the United Kingdom, Tanzania, Australia, Canada and Sudan. It was concluded that patient effective dose and organ doses could be substantially minimized through careful selection of scanning parameters based on clinical indications of study, patient size, and body

  9. ESTIMATION OF THE CONVERSION COEFFICIENTS FROM DOSE-AREA PRODUCT TO EFFECTIVE DOSE FOR BARIUM MEAL EXAMINATIONS FOR ADULT PATIENTS

    Directory of Open Access Journals (Sweden)

    A. V. Vodovatov

    2018-01-01

    Full Text Available Fluoroscopic examinations of the upper gastro-intestinal tract and, especially, barium meal examinations, are commonly performed in a majority of hospitals. These examinations are associated both with substantial individual patient doses and contribution to the collective dose from medical exposure. Effective dose estimation for this type of examinations is complicated due to: 1 the necessity to simulate the moving X-ray irradiation field; 2 differences in study structure for the individual patients; 3 subjectivity of the operators; and 4 differences in the X-ray equipment. The aim of the current study was to estimate conversion coefficients from dose-area product to effective dose for barium meal examinations for the over couch and under couch exposure conditions. The study was based on data collected in the X-ray unit of the surgical department of the St-Petersburg Mariinsky hospital. A model of patient exposure during barium meal examination was developed based on the collected data on fluoroscopy protocols and adult patient irradiation geometry. Conversion coefficients were calculated using PCXMC 2.0 software. Complete examinations were converted into a set of typical fluoroscopy phases and X-ray images, specified by the examined anatomical region and the projection of patient exposure. Conversion coefficients from dose-area product to effective dose were calculated for each phase of the examination and for the complete examination. The resulting values of the conversion coefficients are comparable with published data. Variations in the absolute values of the conversion coefficients can be explained by differences in clinical protocols, models for the estimation of the effective dose and parameters of barium meal examinations. The proposed approach for estimation of effective dose considers such important features of fluoroscopic examinations as: 1 non-uniform structure of examination, 2 significant movement of the X-ray tube within a single

  10. Collective dose estimates by the marine food pathway from liquid radioactive wastes dumped in the Sea of Japan

    International Nuclear Information System (INIS)

    Togawa, O.; Povinec, P.P.; Pettersson, H.B.L.

    1999-01-01

    IAEA-MEL has been engaged in an assessment programme related to radioactive waste dumping by the former USSR and other countries in the western North Pacific Ocean and its marginal seas. This paper focuses on the Sea of Japan and on estimation of collective doses from liquid radioactive wastes. The results from the Japanese-Korean-Russian joint expeditions are summarized, and collective doses for the Japanese population by the marine food pathway are estimated from liquid radioactive wastes dumped in the Sea of Japan and compared with those from global fallout and natural radionuclides. The collective effective dose equivalents by the annual intake of marine products caught in each year show a maximum a few years after the disposals. The total dose from all radionuclides reaches a maximum of 0.8 man Sv in 1990. Approximately 90% of the dose derives from 137Cs, most of which is due to consumption of fish. The total dose from liquid radioactive wastes is approximately 5% of that from global fallout, the contribution of which is below 0.1% of that of natural 210Po

  11. Assessment of organ equivalent doses and effective doses from diagnostic X-ray examinations

    International Nuclear Information System (INIS)

    Park, Sang Hyun

    2003-02-01

    The MIRD-type adult male, female and age 10 phantoms were constructed to evaluate organ equivalent dose and effective dose of patient due to typical diagnostic X-ray examination. These phantoms were constructed with external and internal dimensions of Korean. The X-ray energy spectra were generated with SPEC78. MCNP4B ,the general-purposed Monte Carlo code, was used. Information of chest PA , chest LAT, and abdomen AP diagnostic X-ray procedures was collected on the protocol of domestic hospitals. The results showed that patients pick up approximate 0.02 to 0.18 mSv of effective dose from a single chest PA examination, and 0.01 to 0.19 mSv from a chest LAT examination depending on the ages. From an abdomen AP examination, patients pick up 0.17 to 1.40 mSv of effective dose. Exposure time, organ depth from the entrance surface and X-ray beam field coverage considerably affect the resulting doses. Deviation among medical institutions is somewhat high, and this indicated that medical institutions should interchange their information and the need of education for medical staff. The methodology and the established system can be applied, with some expansion, to dose assessment for other medical procedures accompanying radiation exposure of patients like nuclear medicine or therapeutic radiology

  12. A user's guide to the inhalation and external radiation collective dose module NECTAR-POPDOS

    International Nuclear Information System (INIS)

    Merlin, J.H.

    1982-02-01

    NECTAR-POPDOS is a module of the computer program NECTAR, which has been written in modular form to evaluate radioactive releases from nuclear fuel, their dispersion in the environment and the consequent individual and collective doses to man. The NECTAR-POPDOS module may be used to evaluate external and inhalation collective doses to any specified area of Great Britain, either to the total population or to any one of six age groups, using population data from the 1971 UK census. If a dose-risk function is defined, the module may be used to assess population health effects or for optimisation studies. The module is based on the stand-alone program POPDOS2, and is written in Fortran IV. The input data to the module is described and the module's limitations and sources of inaccuracy are discussed. Appendices to the report contain the necessary Job Control Language for running NECTAR, a list of NECTAR-POPDOS subroutines, and the input and output of two sample NECTAR-POPDOS cases. (author)

  13. Global collective dose commitments from release of long-lived radionuclides. Differential cost-benefit considerations

    International Nuclear Information System (INIS)

    Gjoerup, H.L.

    1977-01-01

    The concept of global collective dose commitment as a measure of total detriment from the release of radioactivity to the environment is outlined. Estimates are given of global collective dose commitments resulting from the release of 14 C and uranium daughter products from the nuclear fuel cycle. Comparisons are made with similar estimates of global collective dose commitments resulting from the use of fossil fuels and certain fertilizers due to their content of uranium and its daughter products. In the case of long-lived radionuclides that remain in circulation in the biosphere, it is shown that the use of global collective dose commitments in differential cost-benefit analysis can lead to questionable results. In differential cost-benefit analysis it is suggested that population exposures should not simply be integrated irrespective of their time of occurrence, but that a certain discount rate should be applied for future doses. This suggestion is examined. (author)

  14. Collective doses to man from dumping of radioactive waste in the Arctic Seas.

    Science.gov (United States)

    Nielsen, S P; Iosjpe, M; Strand, P

    1997-08-25

    A box model for the dispersion of radionuclides in the marine environment covering the Arctic Ocean and the North Atlantic Ocean has been constructed. Collective doses from ingestion pathways have been calculated from unit releases of the radionuclides 3H, 60Co, 63Ni, 90Sr, 129I, 137Cs, 239Pu and 241Am into a fjord on the east coast of NovayaZemlya. The results show that doses for the shorter-lived radionuclides (e.g. 137Cs) are derived mainly from seafood production in the Barents Sea. Doses from the longer-lived radionuclides (e.g. 239Pu) are delivered through marine produce further away from the Arctic Ocean. Collective doses were calculated for two release scenarios, both of which are based on information of the dumping of radioactive waste in the Barents and Kara Seas by the former Soviet Union and on preliminary information from the International Arctic Sea Assessment Programme. A worst-case scenario was assumed according to which all radionuclides in liquid and solid radioactive waste were available for dispersion in the marine environment at the time of dumping. Release of radionuclides from spent nuclear fuel was assumed to take place by direct corrosion of the fuel ignoring the barriers that prevent direct contact between the fuel and the seawater. The second scenario selected assumed that releases of radionuclides from spent nuclear fuel do not occur until after failure of the protective barriers. All other liquid and solid radioactive waste was assumed to be available for dispersion at the time of discharge in both scenarios. The estimated collective dose for the worst-case scenario was about 9 manSv and that for the second scenario was about 3 manSv. In both cases, 137Cs is the radionuclide predicted to dominate the collective doses as well as the peak collective dose rates.

  15. A methodology for the evaluation of collective doses arising from radioactive discharges to the atmosphere

    International Nuclear Information System (INIS)

    Hallam, J.; Linsley, G.S.

    1980-01-01

    The ICRP recommend the use of optimisation as a means of ensuring that the total detriment from any practice is appropriately small in relation to the benefit resulting from its introduction. The calculation of total health detriment requires the evaluation of the complete dose distribution throughout the irradiated population from all isotopes via all pathways. This paper describes methods for the evaluation of collective dose, which may be used in the assessment of detriment. The stages in the assessment of collective dose from an atmospheric release can be summarised as follows: (1) An atmospheric dispersion model is used to evaluate the spatial distribution of activity and thereby the dose to an individual from inhalation and external irradiation at any position with respect to the discharge point. (2) The UK population distribution on a 1 x 1 km grid is then used for the evaluation of collective dose from these pathways. (3) Foodchain models are used to estimate the radioactivity per unit mass in a range of different foodstuffs per unit deposition rate or surface deposit. (4) The distribution of agricultural practices in the UK on a 5 x 5 km grid, taken together with the atmospheric dispersion model allows the estimation of the total activity reaching man via food, and hence the collective dose. This combination of models and data arrays allows assessments to be made of the collective dose due to atmospheric releases of radioactive materials at any geographical location in the United Kingdom. (author)

  16. Plutonium dose-effect relationship

    International Nuclear Information System (INIS)

    Matsuoka, Osamu

    1976-01-01

    Dose in internal exposure to Pu was investigated, and dose-effect relationship was discussed. Dose-effect relationship in internal exposure was investigated by means of two methods, which were relationship between dose and its effect (relationship between μ Ci/Kg and its effect), and exposure dose and its effects (rad-effect), and merits and demerits of two methods were mentioned. Problems in a indication method such as mean dose were discussed with respect to the dose in skeleton, the liver and the lung. Pu-induced osteosarcoma in mice rats, and beagles was described, and differences in its induction between animals were discussed. Pulmonary neoplasma induced by 239 PuO 2 inhalation in beagles was reported, and description was made as to differences in induction of lung cancer between animals when Pu was inhaled and was taken into the lung. A theoretical and experimental study of a extrapolation of the results of the animal experiment using Pu to human cases is necessary. (Serizawa, K.)

  17. Dose-effect Curve for X-radiation in Lymphocytes in Goats

    International Nuclear Information System (INIS)

    Hasanbasic, D.; Saracevic, L.; Sacirbegovic, A.

    1998-01-01

    Dose-effect curve for X-radiation was made based on the analysis of chromosome aberrations in lympocytes of goats. Blood samples from seven goats were irradiated using MOORHEAD method, slightly modified and adapted to our conditions. Linear-square model was used, and the dose-effect curves were fitted by the smallest squares method. Dose-effect curve (collective) for goats is displayed as the following expression: y(D)= 8,6639·10 -3 D + 2,9748·10 -2 D 2 +2,9475·10 -3 . Comparison with some domestic animals such as sheep and pigs showed differences not only with respect to linear-square model, but to other mathematical presentations as well. (author)

  18. Determination of organ doses and effective doses in radiooncology

    International Nuclear Information System (INIS)

    Roth, J.; Martinez, A.E.

    2007-01-01

    Background and Purpose: With an increasing chance of success in radiooncology, it is necessary to estimate the risk from radiation scatter to areas outside the target volume. The cancer risk from a radiation treatment can be estimated from the organ doses, allowing a somewhat limited effective dose to be estimated and compared. Material and Methods: The doses of the radiation-sensitive organs outside the target volume can be estimated with the aid of the PC program PERIDOSE developed by van der Giessen. The effective doses are determined according to the concept of ICRP, whereby the target volume and the associated organs related to it are not taken into consideration. Results: Organ doses outside the target volume are generally < 1% of the dose in the target volume. In some cases, however, they can be as high as 3%. The effective doses during radiotherapy are between 60 and 900 mSv, depending upon the specific target volume, the applied treatment technique, and the given dose in the ICRU point. Conclusion: For the estimation of the radiation risk, organ doses in radiooncology can be calculated with the aid of the PC program PERIDOSE. While evaluating the radiation risk after ICRP, for the calculation of the effective dose, the advanced age of many patients has to be considered to prevent that, e.g., the high gonad doses do not overestimate the effective dose. (orig.)

  19. Medical irradiation and the use of the ''effective dose equivalent'' concept

    International Nuclear Information System (INIS)

    Persson, B.R.R.

    1980-01-01

    The aim of this paper is to demonstrate the use of the effective dose for all kinds of medical irradiation. In order to estimate the 'somatic effective dose' the weighting factors recommended by ICRP 26 have been separated into those for somatic effects and for genetic effects. Calculation of the effective dose in diagnostic radiology procedures must consider the various technical parameters which determine the absorbed dose in the various organs, i.e. beam quality, typical entrance dose and the number of films of each view. Knowledge about these parameters is not always well established and therefore the effective dose estimates are very uncertain. The average dose absorbed by various organs in the case of administration of radionuclides to the body depends to a much higher degree on biological parameters than in the case of external irradiation. In contrast to the variability and lack of reliability of biological data, the physical methods for internal dose calculation are quite elaborate. However, these methods have to be extended to involve the target dose from the radioactivity distributed within the remaining parts of the body. An attempt was made to estimate the somatic effective dose for the most common diagnostic X-ray and nuclear medicine procedures. This would make it possible to compare the risk of X-ray and nuclear medicine techniques on a more equitable basis. The collective effective dose from medical irradiation is estimated for various countries on the basis of reported statistical data. (H.K.)

  20. Normal tissue dose-effect models in biological dose optimisation

    International Nuclear Information System (INIS)

    Alber, M.

    2008-01-01

    Sophisticated radiotherapy techniques like intensity modulated radiotherapy with photons and protons rely on numerical dose optimisation. The evaluation of normal tissue dose distributions that deviate significantly from the common clinical routine and also the mathematical expression of desirable properties of a dose distribution is difficult. In essence, a dose evaluation model for normal tissues has to express the tissue specific volume effect. A formalism of local dose effect measures is presented, which can be applied to serial and parallel responding tissues as well as target volumes and physical dose penalties. These models allow a transparent description of the volume effect and an efficient control over the optimum dose distribution. They can be linked to normal tissue complication probability models and the equivalent uniform dose concept. In clinical applications, they provide a means to standardize normal tissue doses in the face of inevitable anatomical differences between patients and a vastly increased freedom to shape the dose, without being overly limiting like sets of dose-volume constraints. (orig.)

  1. Collection of radiation resistant characteristics reports for instruments and materials in high dose rate environment

    International Nuclear Information System (INIS)

    Kusano, Joichi

    2008-03-01

    This document presents the collected official reports of radiation irradiation study for the candidate materials to be used in high dose rate environment as J-PARC facility. The effect of radiation damage by loss-beam or secondary particle beam of the accelerators influences the performance and the reliability of various instruments. The knowledge on the radiation resistivity of the materials is important to estimate the life of the equipments, the maintenance interval and dose evaluation for the personnel at the maintenance period. The radiation damage consists with mechanical property, electrical property and gas-evolution property. (author)

  2. Collective doses to man from dumping of radioactive waste in the Arctic Seas

    DEFF Research Database (Denmark)

    Nielsen, S.P.; Iosjpe, M.; Strand, P.

    1997-01-01

    A box model for the dispersion of radionuclides in the marine environment covering the Arctic Ocean and the North Atlantic Ocean has been constructed. Collective doses from ingestion pathways have been calculated from unit releases of the radionuclides H-3, (CO)-C-60, Ni-63, Sr-90, I-129, (CS...... Assessment Programme. A worst-case scenario was assumed according to which all radionuclides in liquid and solid radioactive waste were available for dispersion in the marine environment at the time of dumping. Release of radionuclides from spent nuclear fuel was assumed to take place by direct corrosion...... to be available for dispersion at the time of discharge in both scenarios. The estimated collective dose for the worst-case scenario was about 9 manSv and that for the second scenario was about 3 manSv. In both cases, Cs-137 is the radionuclide predicted to dominate the collective doses as well as the peak...

  3. POPFOOD - a computer code for calculating ingestion collective doses from continuous atmospheric releases

    International Nuclear Information System (INIS)

    Hotson, J.; Stacey, A.; Nair, S.

    1980-07-01

    The basic methodology incorporated in the POPFOOD computer code is described, which may be used to calculate equilibrium collective dose rates associated with continuous atmospheric releases and arising from consumption of a broad range of food products. The standard data libraries associated with the code are also described. These include a data library, based on the 1972 agricultural census, describing the spatial distribution of production, in England, Wales and Scotland, of the following food products: milk; beef and veal; pork bacon and ham; poultrymeat; eggs; mutton and lamb; root vegetables; green vegetables; fruit; cereals. Illustrative collective dose calculations were made for the case of 1 Ci per year emissions of 131 I, tritium and 14 C from a typical rural UK site. The calculations indicate that the ingestion pathway results in a greater collective dose than that via inhalation, with the contributions from consumption of root and green vegetables, and cereals being of comparable significance to that from liquid milk consumption, in all three cases. (author)

  4. Concept and approaches used in assessing individual and collective doses from releases of radioactive effluents

    International Nuclear Information System (INIS)

    1988-06-01

    To guide on the applications of the principles for limiting radioactive releases contained in Safety Series 77, the Agency is in the process of preparing a number of safety guides. The first one is this present document which deals with the principal aspects of the methods for the assessment of the individual and collective dose. It aims at giving a general guidance to those responsible for establishing programmes for the determination of individual doses as well as collective doses in connection with licensing a site for a nuclear installation. The document is concerned with the principles applied for calculating individual and collective doses from routine releases of radionuclides to the atmosphere and hydrosphere but not releases directly to the geosphere, as in waste management. These areas will be covered by other Agency publications. 75 refs, figs and tabs

  5. A comparison of the angular dependence of effective dose and effective dose equivalent

    International Nuclear Information System (INIS)

    Sitek, M.A.; Gierga, D.P.; Xu, X.G.

    1996-01-01

    In ICRP (International Commission on Radiological Protection) Publication 60, the set of critical organs and their weighing factors were changed, defining the quantity effective dose, E. This quantity replaced the effective dose equivalent, H E , as defined by ICRP 26. Most notably, the esophagus was added to the list of critical organs. The Monte Carlo neutron/photon transport code MCNP was used to determine the effective dose to sex-specific anthropomorphic phantoms. The phantoms, developed in previous research, were modified to include the esophagus. Monte Carlo simulations were performed for monoenergetic photon beams of energies 0.08 MeV, 0.3 MeV, and 1.0 MeV for various azimuthal and polar angles. Separate organ equivalent doses were determined for male and female phantoms. The resulting organ equivalent doses were calculated from arithmetic mean averages. The angular dependence of effective dose was compared with that of effective dose equivalent reported in previous research. The differences between the two definitions and possible implications to regulatory agencies were summarized

  6. Individual and collective doses associated with the transport of irradiated magnox fuel within the UK

    International Nuclear Information System (INIS)

    Macdonald, H.F.; Mairs, J.H.

    1978-12-01

    A method is described of evaluating the individual and collective doses arising during the transport of irradiated fuel from a system of nuclear power stations to a central reprocessing plant. The doses associated with irradiated Magnox fuel movements in the UK are estimated and compared with those resulting from other phases of the nuclear fuel cycle. In addition, the individual and collective doses implied by the accidental activity release limits contained within the 1973 IAEA Tranport Regulations are discussed. (author)

  7. Application of the ALARA principle to minimize the collective dose in NPP accident management within the containment

    International Nuclear Information System (INIS)

    Bogorad, V.; Slepchenko, O.; Kyrylenko, Y.

    2016-01-01

    The paper focuses on application of the ALARA principle to minimize the collective doses (both for NPP personnel and the public) related to admission of personnel to the containment for accident management activities and depending on operation of ventilation systems. Results from assessment of radiation consequences are applied to a small - break LOCA with failure of LPIS at VVER - 1000 reactors. The public doses are evaluated using up - to - date RODOS, MACCS and HotSpot software for assessment of radiation consequences. The personnel doses are evaluated with MicroShield and InterRAS codes. The time function and optimal value of the collective dose are defined. The developed approach can be applied for minimization of the collective dose for optimization of accident management strategies at NPPs

  8. Estimates of the individual and collective doses in consumer products containing radioactive substances

    International Nuclear Information System (INIS)

    Eleveld, H.; Pruppers, M.J.M.

    2000-01-01

    Here, consumer products refer to products in which radionuclides have been intentionally incorporated and which can be supplied to members of the public without special surveillance. This group of products includes, for instance, ionisation smoke detectors and timepieces with radium-painted dials. These products can cause a radiation dose to members of the public in various stages of life. In 1996 the European Council laid down basic safety standards in Directive 96/29/Euratom for protecting the health of the general public from the dangers arising from ionising radiation. The Directive contains activity concentrations and total activity per radionuclide, the so-called exemption levels, below which a practice using this radionuclide is exempted from the duty to report. Implementing the Directive in the framework of Dutch legislation, the proposed policy for consumer products is to show a distinction between products with activity concentrations and total activity above and below the exemption levels. Besides the exemption levels being used as activity criteria for the consumer products, two dose criteria an individual dose of 10 microSv/a and a collective dose of 1 manSv/a are also employed. In the study leading to this report, the most recent information on consumer products was first collected and the activity per product, and in some cases also the activity concentration, was tested against the exemption levels. Next, the expected individual and collective doses for members of the public were calculated in the storage and trade phase, as well as the user and disposal phase of the consumer products. In the storage and trade phase, the dose for shop personnel was also estimated. Finally, the doses ware tested against the dose criteria. Gas mantles, static elimination devices, gaseous tritium light sources (GTLS), ceramic tiles, welding rods and camera lenses and eyepieces (belongs to the consumer products for which at least one of the activity criteria is exceeded

  9. Health effect of low dose/low dose rate radiation

    International Nuclear Information System (INIS)

    Kodama, Seiji

    2012-01-01

    The clarified and non-clarified scientific knowledge is discussed to consider the cause of confusion of explanation of the title subject. The low dose is defined roughly lower than 200 mGy and low dose rate, 0.05 mGy/min. The health effect is evaluated from 2 aspects of clinical symptom/radiation hazard protection. In the clinical aspect, the effect is classified in physical (early and late) and genetic ones, and is classified in stochastic (no threshold value, TV) and deterministic (with TV) ones from the radioprotection aspect. Although the absence of TV in the carcinogenic and genetic effects has not been proved, ICRP employs the stochastic standpoint from the safety aspect for radioprotection. The lowest human TV known now is 100 mGy, meaning that human deterministic effect would not be generated below this dose. Genetic deterministic effect can be observable only in animal experiments. These facts suggest that the practical risk of exposure to <100 mGy in human is the carcinogenesis. The relationship between carcinogenic risk in A-bomb survivors and their exposed dose are found fitted to the linear no TV model, but the epidemiologic data, because of restriction of subject number analyzed, do not always mean that the model is applicable even below the dose <100 mGy. This would be one of confusing causes in explanation: no carcinogenic risk at <100 mGy or risk linear to dose even at <100 mGy, neither of which is scientifically conclusive at present. Also mentioned is the scarce risk of cancer in residents living in the high background radiation regions in the world in comparison with that in the A-bomb survivors exposed to the chronic or acute low dose/dose rate. Molecular events are explained for the low-dose radiation-induced DNA damage and its repair, gene mutation and chromosome aberration, hypothesis of carcinogenesis by mutation, and non-targeting effect of radiation (bystander effect and gene instability). Further researches to elucidate the low dose

  10. Estimation of absorbed dose and its biological effects in subjects undergoing neuro interventional radiological procedures

    International Nuclear Information System (INIS)

    Basheerudeen, Safa Abdul Syed; Subramanian, Vinodhini; Venkatachalam, Perumal; Joseph, Santosh; Selvam, Paneer; Jose, M.T.; Annalakshmi, O.

    2016-01-01

    Radiological imaging has many applications due to its non-invasiveness, rapid diagnosis of life threatening diseases, and shorter hospital stay which benefit patients of all age groups. However, these procedures are complicated and time consuming, which use repeated imaging views and radiation, thereby increasing patient dose, and collective effective dose to the background at low doses. The effects of high dose radiation are well established. However, the effects of low dose exposure remain to be determined. Therefore, investigating the effect on medically exposed individuals is an alternative source to understand the low dose effects of radiation. The ESD (Entrance Surface Dose) was recorded using Lithium borate based TL dosimeters to measure the doses received by the head, neck and shoulder of the study subjects (n = 70) who underwent procedures like cerebral angiography, coiling, stenting and embolization

  11. Attributability of health effects at low radiation doses

    International Nuclear Information System (INIS)

    Gonzalez, Abel

    2008-01-01

    without allowing for the uncertain possibility of a universal low-dose threshold, concludes that the evidence does not favour the existence of such a universal threshold. Consequently, radiation protection measures ought to be applied to radiation exposure situations involving low radiation doses; 2) They are improvable at individual level. The effect occurrence on specific individuals is not demonstrable on a yes-no basis. Its reality is axiomatic: namely taken by granted as self-evident, solely based on the acceptance of the LNT hypothesis as the only true basis for argument or inference. It is unfeasible to demonstrate the existence of the effects by uncontestable evidence: the truth, validity, or genuineness of their diagnosis for specific individuals cannot be tested and the diagnostic correctness cannot be checked; 3) Their individual causation is counterfactual. The proposition 'a radiation exposure situation caused a health effect on an individual' cannot be explained in terms of the counterfactual conditional 'if the radiation exposure situation had not occurred, then the health effect would not have occurred'; 4) Their occurrence is not individually attestable. In addition to their improvability, any formal proof of the existence of a radiation health effect on any specific individual is generally absent and impossible to obtain at low radiation doses and cannot be established through scientific evidence. The papers winds up that attributability, namely the assumption that some health effect occurs as the result of a given low-dose radiation exposure situation, are distinct notions at the collective and individual level. It then concludes the following: - Increases in the effect (collective) prevalence can be attributable in the sense that the radiological impact on a population can, under certain conditions, be ascribed, namely credited, assigned, and imputed to a specific exposure situation as its cause or source. Attributability is only conditional on the

  12. Attributability of Health Effects at Low Radiation Doses

    International Nuclear Information System (INIS)

    Gonzalez, A.J.

    2011-01-01

    without allowing for the uncertain possibility of a universal low-dose threshold, concludes that the evidence does not favour the existence of such a universal threshold. Consequently, radiation protection measures ought to be applied to radiation exposure situations involving low radiation doses. (ii) They are improvable at individual level. The effect occurrence on specific individuals is not demonstrable on a yes-no basis. Its reality is axiomatic: namely taken by granted as self-evident, solely based on the acceptance of the LNT hypothesis as the only true basis for argument or inference. It is unfeasible to demonstrate the existence of the effects by uncontestable evidence: the truth, validity, or genuineness of their diagnosis for specific individuals cannot be tested and the diagnostic correctness cannot be checked. (iii) Their individual causation is counterfactual. The proposition 'a radiation exposure situation caused a health effect on an individual' cannot be explained in terms of the counterfactual conditional 'if the radiation exposure situation had not occurred, then the health effect would not have occurred'. (iv) Their occurrence is not individually attestable. In addition to their improvability, any formal proof of the existence of a radiation health effect on any specific individual is generally absent and impossible to obtain at low radiation doses and cannot be established through scientific evidence. The papers winds up that attributability, namely the assumption that some health effect occurs as the result of a given low-dose radiation exposure situation, are distinct notions at the collective and individual level. It then concludes the following: - Increases in the effect (collective) prevalence can be attributable in the sense that the radiological impact on a population can, under certain conditions, be ascribed, namely credited, assigned, and imputed to a specific exposure situation as its cause or source. Attributability is only conditional on

  13. Methods for reducing internal collective doses due to contamination of agricultural lands

    International Nuclear Information System (INIS)

    Prister, B.S.; Novikova, N.K.; Tkachenko, N.V.; Nagovisyna, L.I.; Berezhnaya, T.I.; Semenyuk, N.D.; Rudoj, V.M.

    1990-01-01

    Radioactive contamination of agricultural lands in 30 km vicinity of Chernobyl NPP asw well as agricultural products involved in food chains is considered. Attention is paid to population collective doses due to intake of contaminated food. It is shown that target optimization of agricultural production structure in territories where food contamination does not result in increase of population dose limit lies in achievement of minimal inclusion of radionuclides in human diet

  14. Low doses effects

    International Nuclear Information System (INIS)

    Tubiana, M.

    1997-01-01

    In this article is asked the question about a possible carcinogens effect of low dose irradiation. With epidemiological data, knowledge about the carcinogenesis, the professor Tubiana explains that in spite of experiments made on thousand or hundred of thousands animals it has not been possible to bring to the fore a carcinogens effect for low doses and then it is not reasonable to believe and let the population believe that low dose irradiation could lead to an increase of neoplasms and from this point of view any hardening of radiation protection standards could in fact, increase anguish about ionizing radiations. (N.C.)

  15. Effective dose equivalent

    International Nuclear Information System (INIS)

    Huyskens, C.J.; Passchier, W.F.

    1988-01-01

    The effective dose equivalent is a quantity which is used in the daily practice of radiation protection as well as in the radiation hygienic rules as measure for the health risks. In this contribution it is worked out upon which assumptions this quantity is based and in which cases the effective dose equivalent can be used more or less well. (H.W.)

  16. Assessment of Committed Effective Dose due to consumption of Red Sea coral reef fishes collected from the local market (Sudan)

    International Nuclear Information System (INIS)

    Hassona, Rifaat K.; Sam, A.K.; Osman, O.I.; Sirelkhatim, D.A.; LaRosa, J.

    2008-01-01

    An assessment of Committed Effective Dose (CED) due to consumption of Red Sea fish containing 210 Po and 137 Cs was performed for 23 different marine fish samples collected from the local market at Port Sudan. The fish were classified according to their feeding habits into three categories: carnivores, herbivores, and omnivores. Measured activity concentrations of 210 Po were found in the ranges 0.25-6.42 (carnivores), 0.7-5 (omnivores) and 1.5-3.8 (herbivores) Bq/kg fresh weight. In the same study, activity concentrations of Cs-137 were determined to be in the ranges 0.1-0.46 (carnivores), 0.09-0.35 (omnivores) and 0.09-0.32 (herbivores) Bq/kg fresh weight, which were several times lower than those of 210 Po. Appropriate conversion factors were used to derive the CED, which was found to be 0.012, 0.01 and 0.01 (μSv/yr) in carnivores, omnivores and herbivores, respectively, for 137 Cs. This contributes about 0.4% of the total dose exclusively by ingestion of fish. For 210 Po, it was found to be 3.47, 4.81 and 4.14 (μSv/yr) in carnivores, omnivores and herbivores, respectively, which represents 99.6% of the total dose (exclusively by ingestion of fish). The results of CED calculations suggest that the dose received by the Sudanese population from the consumption of marine fish is rather small and that the contribution of 137 Cs is negligible compared to 210 Po

  17. Assessment of Committed Effective Dose due to consumption of Red Sea coral reef fishes collected from the local market (Sudan).

    Science.gov (United States)

    Hassona, Rifaat K; Sam, A K; Osman, O I; Sirelkhatim, D A; LaRosa, J

    2008-04-15

    An assessment of Committed Effective Dose (CED) due to consumption of Red Sea fish containing (210)Po and (137)Cs was performed for 23 different marine fish samples collected from the local market at Port Sudan. The fish were classified according to their feeding habits into three categories: carnivores, herbivores, and omnivores. Measured activity concentrations of (210)Po were found in the ranges 0.25-6.42 (carnivores), 0.7-5 (omnivores) and 1.5-3.8 (herbivores) Bq/kg fresh weight. In the same study, activity concentrations of Cs-137 were determined to be in the ranges 0.1-0.46 (carnivores), 0.09-0.35 (omnivores) and 0.09-0.32 (herbivores) Bq/kg fresh weight, which were several times lower than those of (210)Po. Appropriate conversion factors were used to derive the CED, which was found to be 0.012, 0.01 and 0.01 (microSv/yr) in carnivores, omnivores and herbivores, respectively, for (137)Cs. This contributes about 0.4% of the total dose exclusively by ingestion of fish. For (210)Po, it was found to be 3.47, 4.81 and 4.14 (microSv/yr) in carnivores, omnivores and herbivores, respectively, which represents 99.6% of the total dose (exclusively by ingestion of fish). The results of CED calculations suggest that the dose received by the Sudanese population from the consumption of marine fish is rather small and that the contribution of (137)Cs is negligible compared to (210)Po.

  18. Assessment of Committed Effective Dose due to consumption of Red Sea coral reef fishes collected from the local market (Sudan)

    Energy Technology Data Exchange (ETDEWEB)

    Hassona, Rifaat K. [Sudan Atomic Energy Commission, Khartoum, P.O. Box 3001 (Sudan)], E-mail: rifaatk@yahoo.com; Sam, A.K. [Sudan Atomic Energy Commission, Khartoum, P.O. Box 3001 (Sudan); Osman, O.I. [Chemistry Department, Faculty of Science, University of Khartoum (Sudan); Sirelkhatim, D.A. [Sudan Atomic Energy Commission, Khartoum, P.O. Box 3001 (Sudan); LaRosa, J. [Formerly at IAEA Marine Environment Laboratory, 4 Quai Antoine 1er, MC 98000 (Monaco)

    2008-04-15

    An assessment of Committed Effective Dose (CED) due to consumption of Red Sea fish containing {sup 210}Po and {sup 137}Cs was performed for 23 different marine fish samples collected from the local market at Port Sudan. The fish were classified according to their feeding habits into three categories: carnivores, herbivores, and omnivores. Measured activity concentrations of {sup 210}Po were found in the ranges 0.25-6.42 (carnivores), 0.7-5 (omnivores) and 1.5-3.8 (herbivores) Bq/kg fresh weight. In the same study, activity concentrations of Cs-137 were determined to be in the ranges 0.1-0.46 (carnivores), 0.09-0.35 (omnivores) and 0.09-0.32 (herbivores) Bq/kg fresh weight, which were several times lower than those of {sup 210}Po. Appropriate conversion factors were used to derive the CED, which was found to be 0.012, 0.01 and 0.01 ({mu}Sv/yr) in carnivores, omnivores and herbivores, respectively, for {sup 137}Cs. This contributes about 0.4% of the total dose exclusively by ingestion of fish. For {sup 210}Po, it was found to be 3.47, 4.81 and 4.14 ({mu}Sv/yr) in carnivores, omnivores and herbivores, respectively, which represents 99.6% of the total dose (exclusively by ingestion of fish). The results of CED calculations suggest that the dose received by the Sudanese population from the consumption of marine fish is rather small and that the contribution of {sup 137}Cs is negligible compared to {sup 210}Po.

  19. The estimation of the number of underground coal miners and normalization collective dose at present in China

    International Nuclear Information System (INIS)

    Liu, Fu-dong; Chen, Lu; Pan, Zi-qiang; Liu, Sen-lin; Chen, Ling; Wang, Chun-hong

    2017-01-01

    Due to the improvement of production technology and the adjustment of energy structure, as well as the town-ownership and private-ownership coal mines (TPCM) were closed or merged by national policy, the number of underground miner has changed comparing with 2004 in China, so collective dose and normalization collective dose in different type of coal mine should be changed at the same time. In this paper, according to radiation exposure by different ventilation condition and the annual output, the coal mines in China are divided into three types, which are named as national key coal mines (NKCM), station-owned local coal mines (SLCM) and TPCM. The number of underground coal miner, collective dose and normalization collective dose are estimated at present base on surveying annual output and production efficiency of raw coal in 2005-2014. The typical total value of the underground coal miners recommended in China is 5.1 million in 2005-2009, and in which there are respectively included 1 million, 0.9 million and 3.2 million for NKCM, SLCM and TPCM. There are total of 4.7 million underground coal miner in 2010-2014, and the respectively number for NKCM, SLCM and TPCM are 1.4 million, 1.2 million and 2.1 million. The collective dose in 2005-2009 is 11 335 man.Sv.y"-"1, and in which there are respectively included 280, 495 and 10 560 man.Sv.y"-"1 for NKCM, SLCM and TPCM. As far as 2010-2014, there are total of 7982 man.Sv.y"-"1, and 392, 660 and 6930 man.Sv.y"-"1 for each type of coal mines. Therefore, the main contributor of collective dose is from TPCM. The normalization collective dose in 2005-2009 is 0.0025, 0.015 and 0.117 man.Sv per 10 kt for NKCM, SLCM and TPCM, respectively. As far as 2010-2014, there are 0.0018, 0.010 and 0.107 man.Sv per 10 kt for each type of coal mines. The trend of normalization collective dose is decreased year by year. (authors)

  20. Review of low dose-rate epidemiological studies and biological mechanisms of dose-rate effects on radiation induced carcinogenesis

    International Nuclear Information System (INIS)

    Iwasaki, Toshiyasu; Otsuka, Kensuke; Yoshida, Kazuo

    2015-01-01

    Radiation protection system adopts the linear non-threshold model with using dose and dose-rate effectiveness factor (DDREF). The dose-rate range where DDREF is applied is below 100 mGy per hour, and it is regarded that there are no dose-rate effects at very low dose rate, less than of the order of 10 mGy per year, even from the biological risk evaluation model based on cellular and molecular level mechanisms for maintenance of genetic integrity. Among low dose-rate epidemiological studies, studies of residents in high natural background areas showed no increase of cancer risks at less than about 10 mGy per year. On the other hand, some studies include a study of the Techa River cohort suggested the increase of cancer risks to the similar degree of Atomic bomb survivor data. The difference of those results was supposed due to the difference of dose rate. In 2014, International Commission on Radiological Protection opened a draft report on stem cell biology for public consultations. The report proposed a hypothesis based on the new idea of stem cell competition as a tissue level quality control mechanism, and suggested that it could explain the dose-rate effects around a few milligray per year. To verify this hypothesis, it would be needed to clarify the existence and the lowest dose of radiation-induced stem cell competition, and to elucidate the rate of stem cell turnover and radiation effects on it. As for the turnover, replenishment of damaged stem cells would be the important biological process. It would be meaningful to collect the information to show the difference of dose rates where the competition and the replenishment would be the predominant processes. (author)

  1. Effects of proton radiation dose, dose rate and dose fractionation on hematopoietic cells in mice

    International Nuclear Information System (INIS)

    Ware, J.H.; Rusek, A.; Sanzari, J.; Avery, S.; Sayers, C.; Krigsfeld, G.; Nuth, M.; Wan, X.S.; Kennedy, A.R.

    2010-01-01

    The present study evaluated the acute effects of radiation dose, dose rate and fractionation as well as the energy of protons in hematopoietic cells of irradiated mice. The mice were irradiated with a single dose of 51.24 MeV protons at a dose of 2 Gy and a dose rate of 0.05-0.07 Gy/min or 1 GeV protons at doses of 0.1, 0.2, 0.5, 1, 1.5 and 2 Gy delivered in a single dose at dose rates of 0.05 or 0.5 Gy/min or in five daily dose fractions at a dose rate of 0.05 Gy/min. Sham-irradiated animals were used as controls. The results demonstrate a dose-dependent loss of white blood cells (WBCs) and lymphocytes by up to 61% and 72%, respectively, in mice irradiated with protons at doses up to 2 Gy. The results also demonstrate that the dose rate, fractionation pattern and energy of the proton radiation did not have significant effects on WBC and lymphocyte counts in the irradiated animals. These results suggest that the acute effects of proton radiation on WBC and lymphocyte counts are determined mainly by the radiation dose, with very little contribution from the dose rate (over the range of dose rates evaluated), fractionation and energy of the protons.

  2. Effects of proton radiation dose, dose rate and dose fractionation on hematopoietic cells in mice.

    Science.gov (United States)

    Ware, J H; Sanzari, J; Avery, S; Sayers, C; Krigsfeld, G; Nuth, M; Wan, X S; Rusek, A; Kennedy, A R

    2010-09-01

    The present study evaluated the acute effects of radiation dose, dose rate and fractionation as well as the energy of protons in hematopoietic cells of irradiated mice. The mice were irradiated with a single dose of 51.24 MeV protons at a dose of 2 Gy and a dose rate of 0.05-0.07 Gy/min or 1 GeV protons at doses of 0.1, 0.2, 0.5, 1, 1.5 and 2 Gy delivered in a single dose at dose rates of 0.05 or 0.5 Gy/min or in five daily dose fractions at a dose rate of 0.05 Gy/min. Sham-irradiated animals were used as controls. The results demonstrate a dose-dependent loss of white blood cells (WBCs) and lymphocytes by up to 61% and 72%, respectively, in mice irradiated with protons at doses up to 2 Gy. The results also demonstrate that the dose rate, fractionation pattern and energy of the proton radiation did not have significant effects on WBC and lymphocyte counts in the irradiated animals. These results suggest that the acute effects of proton radiation on WBC and lymphocyte counts are determined mainly by the radiation dose, with very little contribution from the dose rate (over the range of dose rates evaluated), fractionation and energy of the protons.

  3. Assessment of committed effective dose due to consumption of Red Sea coral reef fishes collected from the local market (Sudan)

    International Nuclear Information System (INIS)

    Hassona, R. K; Sam, A. K; Sirelkhatim, D. A.; Osman, O. I.; Larosa, J.

    2008-01-01

    An assessment of committed effective dose (CED) due to consumption of Red Sea fish containing ''2''1''0Po and ''1''3''7Cs was performed for 23 different marine fish samples collected from the local market at Port Sudan. The fish were classified according to their feeding habits into three categories: carnivores, herbivores, and omnivores. Measured activity concentrations of 2 ''1''0Po were found in the ranges 0.25-6.42 (carnivores), 0.7- 5 (omnivores) and 1.5-3.8 (herbivores) Bq/kg fresh weight. In the same study, activity concentrations of Cs-137 were determined to be in the ranges 0.1-0.46 (carnivores), 0.09-0.35 (omnivores) and 0.09-0.32 (herbivores) Bq/kg fresh weigh, which were several times lower than those of ''2''1''0Po. Appropriate conversion factors were used to derive the CED, which was found to be 0.012, 0.01 and 0.01 (μSv/Yr) in carnivores, omnivores and herbivores, respectively, for ''1'''3''7Cs. This contributes about 0.4% of the total dose exclusively by ingestion of fish. For ''2''1''0Po, it was found to be 3.47, 4.81and 4.14 (μSv/Yr) in carnivores, omnivores and herbivores, respectively, which represents 99.6% of the total dose (exclusively by ingestion of fish ). The results of CED calculations suggest that the dose received by the Sudanese population from the consumption of marine fish is rather small and that the contribution of ''1''3''7Cs is negligible compared to ''2''1''0Po.(Author)

  4. Low doses effects and gamma radiations low dose rates

    International Nuclear Information System (INIS)

    Averbeck, D.

    1999-01-01

    This expose wishes for bringing some definitions and base facts relative to the problematics of low doses effects and low dose rates effects. It shows some already used methods and some actual experimental approaches by focusing on the effects of ionizing radiations with a low linear energy transfer. (N.C.)

  5. Cytogenetic biodosimetry and dose-rate effect after radioiodine therapy for thyroid cancer

    Energy Technology Data Exchange (ETDEWEB)

    Khvostunov, Igor K. [Russian Ministry of Health Care, A.F. Tsyb Medical Radiological Research Center, Branch of the National Medical Research Radiological Centre, Obninsk, Kaluga Region (Russian Federation); Nagasaki University, Department of Radiation Molecular Epidemiology, Atomic Bomb Disease Institute, Nagasaki (Japan); Saenko, Vladimir A.; Yamashita, Shunichi [Nagasaki University, Department of Radiation Molecular Epidemiology, Atomic Bomb Disease Institute, Nagasaki (Japan); Krylov, Valeri; Rodichev, Andrei [Russian Ministry of Health Care, A.F. Tsyb Medical Radiological Research Center, Branch of the National Medical Research Radiological Centre, Obninsk, Kaluga Region (Russian Federation)

    2017-08-15

    This study set out to investigate chromosomal damage in peripheral blood lymphocytes of thyroid cancer patients receiving {sup 131}I for thyroid remnant ablation or treatment of metastatic disease. The observed chromosomal damage was further converted to the estimates of whole-body dose to project the adverse side effects. Chromosomal aberration analysis was performed in 24 patients treated for the first time or after multiple courses. Blood samples were collected before treatment and 3 or 4 days after administration of 2-4 GBq of {sup 131}I. Both conventional cytogenetic and chromosome 2, 4 and 12 painting assays were used. To account for dose-rate effect, a dose-protraction factor was applied to calculate the whole-body dose. The mean dose was 0.62 Gy (95% CI: 0.44-0.77 Gy) in the subgroup of patients treated one time and 0.67 Gy (95% CI: 0.03-1.00 Gy) in re-treated patients. These dose estimates are about 1.7-fold higher than those disregarding the effect of exposure duration. In re-treated patients, the neglected dose-rate effect can result in underestimation of the cumulative whole-body dose by the factor ranging from 2.6 to 6.8. Elevated frequency of chromosomal aberrations observed in re-treated patients before radioiodine therapy allows estimation of a cumulative dose received from all previous treatments. (orig.)

  6. UNIDOSE - a computer program for the calculation of individual and collective doses from airborne radioactive pollutants

    International Nuclear Information System (INIS)

    Karlberg, O.; Schwartz, H.; Forssen, B.-H.; Marklund, J.-E.

    1979-01-01

    UNIDOSE is a program system for calculating the consequences of a radioactive release to the atmosphere. The program is applicable for computation of dispersion in a rnage of 0 - 50 km from the release point. The Gaussion plume model is used for calculating the external dose from activity in the atmosphere, on the ground and the internal dose via inhalation. Radioactive decay, as well as growth and decay of daughter products are accounted for. The influence of dry deposition and wash-out are also considered. It is possible to treat time-dependent release-rates of 1 - 24 hours duration and constant release-rates for up to one year. The program system also contains routines for the calculation of collective dose and health effects. The system operates in a statistical manner. Many weather-situations, based on measured data, can be analysed and statistical properties, such as cumulative frequences, can be calculated. (author)

  7. The assessment of collective dose for travellers travelling by water

    International Nuclear Information System (INIS)

    Yue Qingyu; Jiang Ping; Jin Hua

    1992-06-01

    The major contribution to the various radiation exposure received by mankind comes from natural radiation. Some environmental change caused by human beings and some activities of mankind may decrease or increase the radiation exposure level from natural radiation. People travelling by air will receive more exposure dose and by water will receive less. China has about 18000 km coast line and the inland water transportation is very flourishing. According to statistic data from Ministry of Transportation in 1988, the turnover in that year was about 2 x 10 10 man.km. The total number of fisherman for inshore fishing was nearly two million reported by Ministry of Farming, Animal Husbandry and Fishery. We measured 212 points in six typical shipping lines of inshore lines and inland rivers, and the distance was 5625 km. The average natural radiation exposure dose rate received by travellers in each shipping line was calculated. From that the assessment of collective dose equivalent for passengers by water and fishermen was derived. The value is 32.7 man.Sv for passengers and 265.3 man.Sv for fishermen

  8. The assessment of collective dose for travellers travelling by water

    International Nuclear Information System (INIS)

    Yue Qingyu; Jian Ping; Jin Hua

    1994-01-01

    The major contribution to various radiation exposure received by mankind comes from natural radiation. Some environmental change caused by human beings and some activities of mankind may decrease or increase the radiation exposure level from natural radiation. China has about 18000 km coast line and the inland water transportation is very flourishing. According to statistic data from Ministry of Transportation in 1988, the turnover in that year was about 2 x 10 10 man·km. The total number of fisherman for inshore fishing was nearly two millions reported by Ministry of Farming, Animal Husbandry and Fishery. We measured exposure dose rates over 212 points in six typical shipping lines of inshore lines and inland rivers, and the distance was 5625 km. The average natural radiation exposure dose rate received by travellers in each shipping line was calculated. From that the assessment of collective dose equivalent for passengers by water and fishermen was derived. The value is 32.7 man·Sv for passengers and 265.3 man·Sv for fishermen

  9. Estimation of the collective ionizing dose in the Portuguese population for the years 2011 and 2012, due to nuclear medicine exams.

    Science.gov (United States)

    Costa, F; Teles, P; Nogueira, A; Barreto, A; Santos, A I; Carvalho, A; Martins, B; Oliveira, C; Gaspar, C; Barros, C; Neves, D; Costa, D; Rodrigues, E; Godinho, F; Alves, F; Cardoso, G; Cantinho, G; Conde, I; Vale, J; Santos, J; Isidoro, J; Pereira, J; Salgado, L; Rézio, M; Vieira, M; Simãozinho, P; Almeida, P; Castro, R; Parafita, R; Pintão, S; Lúcio, T; Reis, T; Vaz, P

    2015-01-01

    In 2009-2010 a Portuguese consortium was created to implement the methodologies proposed by the Dose Datamed II (DDM2) project, aiming to collect data from diagnostic X-ray and nuclear medicine (NM) procedures, in order to determine the most frequently prescribed exams and the associated ionizing radiation doses for the Portuguese population. The current study is the continuation of this work, although it focuses only on NM exams for the years 2011 and 2012. The annual frequency of each of the 28 selected NM exams and the average administered activity per procedure was obtained by means of a nationwide survey sent to the 35 NM centres in Portugal. The results show a reduction of the number of cardiac exams performed in the last two years compared with 2010, leading to a reduction of the annual average effective dose of Portuguese population due to NM exams from 0.08 mSv ± 0.017 mSv/caput to 0.059 ± 0.011 mSv/caput in 2011 and 0.054 ± 0.011 mSv/caput in 2012. Portuguese total annual average collective effective dose due to medical procedures was estimated to be 625.6 ± 110.9 manSv in 2011 and 565.1 ± 117.3 manSv in 2012, a reduction in comparison with 2010 (840.3 ± 183.8 manSv). The most frequent exams and the ones that contributed the most for total population dose were the cardiac and bone exams, although a decrease observed in 2011 and in 2012 was verified. The authors intend to perform this study periodically to identify trends in the annual Portuguese average effective dose and to help to raise awareness about the potential dose optimization. Copyright © 2014 Elsevier España, S.L.U. and SEMNIM. All rights reserved.

  10. Mean annual and collective radiation doses of Perm' province personnel

    International Nuclear Information System (INIS)

    Poplavskij, K.K.; Rotenberg, L.I.

    1978-01-01

    The average annual and collective doses of radiation received by personnel of radiologic facilities and by the population of the region under study as a whole are estimated. Tabular data on radiation loads are presented according to the age and sex of personnel and to the type of radiation sources used. The procedure employed in this study allows one to evaluate objectively the conditions of work with sources of ionizing radiation

  11. Radiation dose in cardiac SPECT/CT: An estimation of SSDE and effective dose

    International Nuclear Information System (INIS)

    Abdollahi, Hamid; Shiri, Isaac; Salimi, Yazdan; Sarebani, Maghsoud; Mehdinia, Reza; Deevband, Mohammad Reza; Mahdavi, Seied Rabi; Sohrabi, Ahmad; Bitarafan-Rajabi, Ahmad

    2016-01-01

    Aims: The dose levels for Computed Tomography (CT) localization and attenuation correction of Single Photon Emission Computed Tomography (SPECT) are limited and reported as Volume Computed Tomography Dose Index (CTDIvol) and Dose-Length Product (DLP). This work presents CT dose estimation from Cardiac SPECT/CT based on new American Association of Physicists in Medicine (AAPM) Size Specific Dose Estimation (SSDE) parameter, effective dose, organ doses and also emission dose from nuclear issue. Material and methods: Myocardial perfusion SPECT/CT for 509 patients was included in the study. SSDE, effective dose and organ dose were calculated using AAPM guideline and Impact-Dose software. Data were analyzed using R and SPSS statistical software. Spearman-Pearson correlation test and linear regression models were used for finding correlations and relationships among parameters. Results: The mean CTDIvol was 1.34 mGy ± 0.19 and the mean SSDE was 1.7 mGy ± 0.16. The mean ± SD of effective dose from emission, CT and total dose were 11.5 ± 1.4, 0.49 ± 0.11 and 12.67 ± 1.73 (mSv) respectively. The mean ± SD of effective dose from emission, CT and total dose were 11.5 ± 1.4, 0.49 ± 0.11 and 12.67 ± 1.73 (mSv) respectively. The spearman test showed that correlation between body size and organ doses is significant except thyroid and red bone marrow. CTDIvol was strongly dependent on patient size, but SSDE was not. Emission dose was strongly dependent on patient weight, but its dependency was lower to effective diameter. Conclusion: The dose parameters including CTDIvol, DLP, SSDE, effective dose values reported here are very low and below the reference level. This data suggest that appropriate CT acquisition parameters in SPECT/CT localization and attenuation correction are very beneficial for patients and lowering cancer risks.

  12. Radiation dose in cardiac SPECT/CT: An estimation of SSDE and effective dose

    Energy Technology Data Exchange (ETDEWEB)

    Abdollahi, Hamid, E-mail: Hamid_rbp@yahoo.com [Department of Medical Physics, School of Medicine, Iran University of Medical Sciences, Tehran (Iran, Islamic Republic of); Shiri, Isaac [Department of Medical Physics, School of Medicine, Iran University of Medical Sciences, Tehran (Iran, Islamic Republic of); Salimi, Yazdan [Biomedical Engineering and Medical Physics Department, Faculty of Medicine, Shahid Beheshti University of Medical Sciences, Tehran (Iran, Islamic Republic of); Sarebani, Maghsoud; Mehdinia, Reza [Department of Medical Physics, School of Medicine, Iran University of Medical Sciences, Tehran (Iran, Islamic Republic of); Deevband, Mohammad Reza [Biomedical Engineering and Medical Physics Department, Faculty of Medicine, Shahid Beheshti University of Medical Sciences, Tehran (Iran, Islamic Republic of); Mahdavi, Seied Rabi [Department of Medical Physics, School of Medicine, Iran University of Medical Sciences, Tehran (Iran, Islamic Republic of); Radiation Biology Research Center, Iran University of Medical Sciences, Tehran (Iran, Islamic Republic of); Sohrabi, Ahmad [Department of Biostatistics, School of Public Health, Iran University of Medical Sciences, Tehran (Iran, Islamic Republic of); Bitarafan-Rajabi, Ahmad, E-mail: bitarafan@hotmail.com [Department of Medical Physics, School of Medicine, Iran University of Medical Sciences, Tehran (Iran, Islamic Republic of); Department of Nuclear Medicine, Rajaei Cardiovascular, Medical and Research Center, Iran University of Medical Sciences, Tehran (Iran, Islamic Republic of)

    2016-12-15

    Aims: The dose levels for Computed Tomography (CT) localization and attenuation correction of Single Photon Emission Computed Tomography (SPECT) are limited and reported as Volume Computed Tomography Dose Index (CTDIvol) and Dose-Length Product (DLP). This work presents CT dose estimation from Cardiac SPECT/CT based on new American Association of Physicists in Medicine (AAPM) Size Specific Dose Estimation (SSDE) parameter, effective dose, organ doses and also emission dose from nuclear issue. Material and methods: Myocardial perfusion SPECT/CT for 509 patients was included in the study. SSDE, effective dose and organ dose were calculated using AAPM guideline and Impact-Dose software. Data were analyzed using R and SPSS statistical software. Spearman-Pearson correlation test and linear regression models were used for finding correlations and relationships among parameters. Results: The mean CTDIvol was 1.34 mGy ± 0.19 and the mean SSDE was 1.7 mGy ± 0.16. The mean ± SD of effective dose from emission, CT and total dose were 11.5 ± 1.4, 0.49 ± 0.11 and 12.67 ± 1.73 (mSv) respectively. The mean ± SD of effective dose from emission, CT and total dose were 11.5 ± 1.4, 0.49 ± 0.11 and 12.67 ± 1.73 (mSv) respectively. The spearman test showed that correlation between body size and organ doses is significant except thyroid and red bone marrow. CTDIvol was strongly dependent on patient size, but SSDE was not. Emission dose was strongly dependent on patient weight, but its dependency was lower to effective diameter. Conclusion: The dose parameters including CTDIvol, DLP, SSDE, effective dose values reported here are very low and below the reference level. This data suggest that appropriate CT acquisition parameters in SPECT/CT localization and attenuation correction are very beneficial for patients and lowering cancer risks.

  13. Epidemiological methods for assessing dose-response and dose-effect relationships

    DEFF Research Database (Denmark)

    Kjellström, Tord; Grandjean, Philippe

    2007-01-01

    Selected Molecular Mechanisms of Metal Toxicity and Carcinogenicity General Considerations of Dose-Effect and Dose-Response Relationships Interactions in Metal Toxicology Epidemiological Methods for Assessing Dose-Response and Dose-Effect Relationships Essential Metals: Assessing Risks from Deficiency......Description Handbook of the Toxicology of Metals is the standard reference work for physicians, toxicologists and engineers in the field of environmental and occupational health. This new edition is a comprehensive review of the effects on biological systems from metallic elements...... access to a broad range of basic toxicological data and also gives a general introduction to the toxicology of metallic compounds. Audience Toxicologists, physicians, and engineers in the fields of environmental and occupational health as well as libraries in these disciplines. Will also be a useful...

  14. Bayesian estimation of dose rate effectiveness

    International Nuclear Information System (INIS)

    Arnish, J.J.; Groer, P.G.

    2000-01-01

    A Bayesian statistical method was used to quantify the effectiveness of high dose rate 137 Cs gamma radiation at inducing fatal mammary tumours and increasing the overall mortality rate in BALB/c female mice. The Bayesian approach considers both the temporal and dose dependence of radiation carcinogenesis and total mortality. This paper provides the first direct estimation of dose rate effectiveness using Bayesian statistics. This statistical approach provides a quantitative description of the uncertainty of the factor characterising the dose rate in terms of a probability density function. The results show that a fixed dose from 137 Cs gamma radiation delivered at a high dose rate is more effective at inducing fatal mammary tumours and increasing the overall mortality rate in BALB/c female mice than the same dose delivered at a low dose rate. (author)

  15. Cytogenetic effects of low-dose radiation

    International Nuclear Information System (INIS)

    Metalli, P.

    1983-01-01

    The effects of ionizing radiation on chromosomes have been known for several decades and dose-effect relationships are also fairly well established in the mid- and high-dose and dose-rate range for chromosomes of mammalian cells. In the range of low doses and dose rates of different types of radiation few data are available for direct analysis of the dose-effect relationships, and extrapolation from high to low doses is still the unavoidable approach in many cases of interest for risk assessment. A review is presented of the data actually available and of the attempts that have been made to obtain possible generalizations. Attention is focused on some specific chromosomal anomalies experimentally induced by radiation (such as reciprocal translocations and aneuploidies in germinal cells) and on their relevance for the human situation. (author)

  16. Computer tape library for collective dose assessments in the European Community

    International Nuclear Information System (INIS)

    Jones, J.A.; Kelly, G.N.

    1981-01-01

    A computer tape library has been established which can readily be applied to enable calculations to be made of the collective dose to the population of the European Community from radioactive effluent discharges within the EC. The background to the development of the tape library and details of its contents, method of application and availability are summarised in this note. (author)

  17. Development of evaluation method of collective dose of general public considering the daily life activity and time use

    International Nuclear Information System (INIS)

    Nagaoka, Toshi; Saito, Kimiaki; Sakamoto, Ryuichi; Tsutsumi, Masahiro; Moriuchi, Shigeru

    1994-11-01

    A code for evaluation of collective dose of general public to natural radiation has been developed, in which the variation of dose rate due to place of stay is taken into consideration. Only external exposure to natural radiation is subject to discussion in this report. Strict manner of dose evaluation requires the dose rate and the time period of stay for each place and for each person. It is possible to know (measure) them all, but not practicable. In this code, dose rate information was obtained from actually measured data by the authors and estimation based on the environmental conditions. Information on the time period of stay was obtained from a Survey Data on Time Use and Leisure Activities by Management and Coordination Agency, and from Statistical Yearbook of Tokyo with some realistic assumptions. By using them, collective dose was evaluated taking both the daily life style and dose rate varying place by place into consideration. In this report, the dose evaluation code and the results about doses for Tokyo citizens are mentioned. (author)

  18. Occupational Doses and the Contribution to the Population Dose in Korea

    Energy Technology Data Exchange (ETDEWEB)

    Han, Seung Jae; Kyu, Hwan Jeong [KINS, Daejeon (Korea, Republic of)

    2016-05-15

    The purpose of this study is to evaluate the occupational exposure records in terms of the control of exposure for radiation workers and dose reduction. The study includes the estimates of the number of people exposed occupationally, the effective collective doses and mean doses to those exposed. In addition, the study includes an estimate of the contribution of occupational exposure to the Korean population dose. The exposure of radiation workers in occupational field includes medical radiology, industrial applications such as radiography, nuclear power, and some research activities. Occupational exposure from medical radiology practices includes the contributions from diagnostic x-ray procedures, dental radiography, nuclear medicine and radiation therapy. The control of exposure for radiation workers, and the measures necessary to maintain radiation exposure as low as reasonably achievable (ALARA) are specified in Subparagraph 3 and Subparagraph 4 of Article 91 (1) of the Korea Nuclear Safety Act (KNSA), respectively. Therefore, from a regulatory perspective, the exposure data of the workers are primarily for verification of the adequacy of the control of exposure, radiation protection and implementation of ALARA. The number of people exposed occupationally, the effective collective doses and mean doses to those exposed, and average effective doses from occupational exposure during the period of 2009 to 2013 have been evaluated. In general, radiation workers were increasing in number annually, but the mean doses for those exposed each year showed the control of exposures were mostly considered met within the dose limit in KNSA. Nevertheless, it was shown that the continuous efforts would be needed to reduce doses and thus to implement ALARA regulatory requirements. In radiation occupations, the application of ICRP radiation protection principles will ensure good practice and decreasing exposures. Over the period of 5 years, the contributions of the annual

  19. Occupational Doses and the Contribution to the Population Dose in Korea

    International Nuclear Information System (INIS)

    Han, Seung Jae; Kyu, Hwan Jeong

    2016-01-01

    The purpose of this study is to evaluate the occupational exposure records in terms of the control of exposure for radiation workers and dose reduction. The study includes the estimates of the number of people exposed occupationally, the effective collective doses and mean doses to those exposed. In addition, the study includes an estimate of the contribution of occupational exposure to the Korean population dose. The exposure of radiation workers in occupational field includes medical radiology, industrial applications such as radiography, nuclear power, and some research activities. Occupational exposure from medical radiology practices includes the contributions from diagnostic x-ray procedures, dental radiography, nuclear medicine and radiation therapy. The control of exposure for radiation workers, and the measures necessary to maintain radiation exposure as low as reasonably achievable (ALARA) are specified in Subparagraph 3 and Subparagraph 4 of Article 91 (1) of the Korea Nuclear Safety Act (KNSA), respectively. Therefore, from a regulatory perspective, the exposure data of the workers are primarily for verification of the adequacy of the control of exposure, radiation protection and implementation of ALARA. The number of people exposed occupationally, the effective collective doses and mean doses to those exposed, and average effective doses from occupational exposure during the period of 2009 to 2013 have been evaluated. In general, radiation workers were increasing in number annually, but the mean doses for those exposed each year showed the control of exposures were mostly considered met within the dose limit in KNSA. Nevertheless, it was shown that the continuous efforts would be needed to reduce doses and thus to implement ALARA regulatory requirements. In radiation occupations, the application of ICRP radiation protection principles will ensure good practice and decreasing exposures. Over the period of 5 years, the contributions of the annual

  20. A users guide to the POPDOS program for evaluating collective doses

    International Nuclear Information System (INIS)

    Henning, M.J.

    1975-09-01

    A complete description is given of the input data needed to use the computer program POPDOS for estimating doses in England and Wales following atmospheric releases of radioactivity. Details are given of the Job Control Language used for normal execution of the program. A complete test case is included to facilitate program transfer to other computers. POPDOS is written in Fortran IV (level H) and is compiled under OPT = 2, using ASP3 on the IBM 370/168 computer. A list of subroutines and their functions is given together with a tabulation of the major dimensioned variables. Finally there is a description of the procedure by which a collective dose surface can be generated using the CALCOMP plotting facilities. (author)

  1. Low-dose effect on blood chromosomes

    International Nuclear Information System (INIS)

    Pohl-Rueling, J.

    1992-01-01

    Linear dose response relationships of biological effects at low doses are experimentally and theoretically disputed. Structural chromosome aberration rates at doses ranging from normal background exposures up to about 30 mGy/yr in vivo and up to 50 mGy in vitro were investigated by the author and other scientists. Results are comparable and dose effect curves reveal following shapes; within the normal burden and up to 2-10 mGy/yr in vivo rates they increase sharply to about 3-6 times the lowest values; subsequent doses either from natural, occupational or accidental exposures up to about 30 mGy/yr yield either constant aberration rates, assuming a plateau, or perhaps even a decrease. In vitro experiments show comparable results up to 50 mGy. Other biological effects seem to have similar dose dependencies. The non-linearity of low-dose effects can be explained by induction of repair enzymes at certain damage to the DNA. This hypothesis is sustained experimentally and theoretically by several papers in literature. (author). 14 refs., 5 figs

  2. Individual and collective dose rates from naturally-occurring radionuclides in seafood

    International Nuclear Information System (INIS)

    Pentreath, R.J.; Camplin, W.C.; Allington, D.J.

    1989-01-01

    Although seafoods are not a large item in the UK diet, they are of interest because of the above-average quantities of naturally-occurring radionuclides which they contain -particularly shellfish. The single most important contributor is 210 Po; studies have therefore been made to examine the contribution which this nuclide makes to the dose received, both collectively and to individual high-rate consumers of shellfish. (author)

  3. Effective dose and dose to crystalline lens during angiographic procedures

    International Nuclear Information System (INIS)

    Pages, J.

    1998-01-01

    The highest radiation doses levels received by radiologists are observed during interventional procedures. Doses to forehead and neck received by a radiologist executing angiographic examinations at the department of radiology at the academic hospital (AZ-VUB) have been measured for a group of 34 examinations. The doses to crystalline lens and the effective doses for a period of one year have been estimated. For the crystalline lens the maximum dose approaches the ICRP limit, that indicates the necessity for the radiologist to use leaded glasses. (N.C.)

  4. Insignificant levels of dose

    International Nuclear Information System (INIS)

    Webb, G.A.M.; McLean, A.S.

    1977-01-01

    The procedures recommended by the International Commission on Radiological Protection (ICRP) for making decisions concerning controllable sources of radiation exposure of the public include 'justification' and 'optimisation'. The tool recommended by the ICRP for reaching these decisions is collective dose or dose commitment supplemented by consideration of doses to individuals. In both these considerations the practical problem arises of whether very small doses to large numbers of people should contribute to the final decision-making process. It may be that at levels of dose which are small increments on natural background, the relationship between dose and effect is linear even though the slope may be close to zero. If so, collective dose is a meaningful concept and the calculation of total detriment for the purpose of justification could legitimately include all doses. In the calculation of collective doses for the purpose of optimisation, which involves decisions on how much money or resource should be allocated to dose reduction, it is necessary to appraise radiation detriment realistically. At low levels of dose to the individual such as those small by comparison with variations in natural background within the UK, the risk to the individual is such that his well-being will not be significantly changed by the presence or absence of the radiation dose. These small doses, which are well below the point at which an individual attaches significance, should not carry a societal significance. Societal acceptance of risk is analysed with a view to assessing a level of possible risk, and hence dose, below which resources should not in general be diverted to secure further reduction. A formulation for collective dose commitment is proposed incorporating a cut-off to exclude insignificant doses. The implications of this formulation in practical situations are discussed

  5. Gamma dose rate effect on JFET transistors

    International Nuclear Information System (INIS)

    Assaf, J.

    2011-04-01

    The effect of Gamma dose rate on JFET transistors is presented. The irradiation was accomplished at the following available dose rates: 1, 2.38, 5, 10 , 17 and 19 kGy/h at a constant dose of 600 kGy. A non proportional relationship between the noise and dose rate in the medium range (between 2.38 and 5 kGy/h) was observed. While in the low and high ranges, the noise was proportional to the dose rate as the case of the dose effect. This may be explained as follows: the obtained result is considered as the yield of a competition between many reactions and events which are dependent on the dose rate. At a given values of that events parameters, a proportional or a non proportional dose rate effects are generated. No dependence effects between the dose rate and thermal annealing recovery after irradiation was observed . (author)

  6. A methodology for the evaluation of the collective dose from radioactivity in terrestrial food chains

    International Nuclear Information System (INIS)

    Simmonds, J.R.; Linsley, G.S.

    1980-02-01

    A methodology is described for the evaluation of the collective dose from radioactivity in the terrestrial food chains. It involves the use of an agricultural grid for Great Britain from which the geographical distribution of each of the main cereal, vegetable, fruit and animal products around any given point can be evaluated. A description is given of the procedure by which the grid was assembled. The use of the grid is demonstrated in an example in which the collective doses associated with the milk pathway to man following the routine discharge to air of iodine-131 are compared for two coastal sites in markedly different agricultural regions. (author)

  7. Dose and Dose-Rate Effectiveness Factor (DDREF); Der Dosis- und Dosisleistungs-Effektivitaetsfaktor (DDREF)

    Energy Technology Data Exchange (ETDEWEB)

    Breckow, Joachim [Fachhochschule Giessen-Friedberg, Giessen (Germany). Inst. fuer Medizinische Physik und Strahlenschutz

    2016-08-01

    For practical radiation protection purposes it is supposed that stochastic radiation effects a determined by a proportional dose relation (LNT). Radiobiological and radiation epidemiological studies indicated that in the low dose range a dependence on dose rates might exist. This would trigger an overestimation of radiation risks based on the LNT model. OCRP had recommended a concept to combine all effects in a single factor DDREF (dose and dose-Rate effectiveness factor). There is still too low information on cellular mechanisms of low dose irradiation including possible repair and other processes. The Strahlenschutzkommission cannot identify a sufficient scientific justification for DDREF and recommends an adaption to the actual state of science.

  8. Organ dose and effective dose with the EOS scanner in spine deformity surgery

    DEFF Research Database (Denmark)

    Heide Pedersen, Peter; Petersen, Asger Greval; Eiskjær, Søren Peter

    2016-01-01

    Organ dose and effective dose with the EOS scanner in spine deformity surgery. A study on anthropomorphic phantoms describing patient radiation exposure in full spine examinations. Authors: Peter Heide Pedersen, Asger Greval Petersen, Søren Peter Eiskjær. Background: Ionizing radiation potentially...... quality images while at the same time reducing radiation dose. At our institution we use the EOS for pre- and postoperative full spine examinations. Purpose: The purpose of the study is to make first time organ dose and effective dose evaluations with micro-dose settings in full spine examinations. Our...... hypothesis is that organ dose and effective doses can be reduced 5-10 times compared to standard settings, without too high image-quality trade off, resulting in a theoretical reduction of radiation induced cancer. Methods: Patient dosimetry is performed on anthropomorphic child phantoms, representing a 5...

  9. Effective radiation doses in CT colonography: results of an inventory among research institutions

    International Nuclear Information System (INIS)

    Jensch, Sebastiaan; Gelder, Rogier E. van; Lameris, Johan S.; Stoker, Jaap; Venema, Henk W.; Reitsma, Johannes B.; Bossuyt, Patrick M.M.

    2006-01-01

    The purpose of this study was to estimate the effective dose that is currently used in CT colonography using scan parameters that were collected for this purpose, and to investigate trends in time. PubMed was systematically searched from 1996 until January 2004 for studies investigating CT colonography. Research institutions were contacted and asked for their current scan protocol. Thirty-six institutions published 74 studies. Twenty-eight of the 36 institutions provided their current protocol. The median effective dose in 2004 was 5.1 mSv (range 1.2-11.7 mSv) per position. Most institutions (93%) scan in both the supine and prone positions. The median mAs value was 67 mAs (range 20-200), median collimation was 2.5 mm (range 0.75-5). From 1996 until 2004 a significant decrease in mAs and collimation (P=0.006, P<0.0001, respectively) was observed, while institutions that used a multislice scanner increased (P<0.0001). The effective dose remained constant (P=0.76). In 2004 the median effective dose for a complete CT colonography was 10.2 mSv. Despite the increasing use of multislice scanners, which are slightly less dose-efficient, the median effective dose remained approximately constant between 1996 and 2004. This is mainly caused by the use of lower mAs settings. (orig.)

  10. Adrenaline (epinephrine) dosing period and survival after in-hospital cardiac arrest: a retrospective review of prospectively collected data.

    Science.gov (United States)

    Warren, Sam A; Huszti, Ella; Bradley, Steven M; Chan, Paul S; Bryson, Chris L; Fitzpatrick, Annette L; Nichol, Graham

    2014-03-01

    Expert guidelines for treatment of cardiac arrest recommend administration of adrenaline (epinephrine) every three to five minutes. However, the effects of different dosing periods of epinephrine remain unclear. We sought to evaluate the association between epinephrine average dosing period and survival to hospital discharge in adults with an in-hospital cardiac arrest (IHCA). We performed a retrospective review of prospectively collected data on 20,909 IHCA events from 505 hospitals participating in the Get With The Guidelines-Resuscitation (GWTG-R) quality improvement registry. Epinephrine average dosing period was defined as the time between the first epinephrine dose and the resuscitation endpoint, divided by the total number of epinephrine doses received subsequent to the first epinephrine dose. Associations with survival to hospital discharge were assessed by using generalized estimating equations to construct multivariable logistic regression models. Compared to a referent epinephrine average dosing period of 4 to <5 min per dose, survival to hospital discharge was significantly higher in patients with the following epinephrine average dosing periods: for 6 to <7 min/dose, adjusted odds ratio [OR], 1.41 (95%CI: 1.12, 1.78); for 7 to <8 min/dose, adjusted OR, 1.30 (95%CI: 1.02, 1.65); for 8 to <9 min/dose, adjusted OR, 1.79 (95%CI: 1.38, 2.32); for 9 to <10 min/dose, adjusted OR, 2.17 (95%CI: 1.62, 2.92). This pattern was consistent for both shockable and non-shockable cardiac arrest rhythms. Less frequent average epinephrine dosing than recommended by consensus guidelines was associated with improved survival of in-hospital cardiac arrest. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  11. The effect of radiation dose on mouse skeletal muscle remodeling

    International Nuclear Information System (INIS)

    Hardee, Justin P.; Puppa, Melissa J.; Fix, Dennis K.; Gao, Song; Hetzler, Kimbell L.; Bateman, Ted A.; Carson, James A.

    2014-01-01

    The purpose of this study was to determine the effect of two clinically relevant radiation doses on the susceptibility of mouse skeletal muscle to remodeling. Alterations in muscle morphology and regulatory signaling were examined in tibialis anterior and gastrocnemius muscles after radiation doses that differed in total biological effective dose (BED). Female C57BL/6 (8-wk) mice were randomly assigned to non-irradiated control, four fractionated doses of 4 Gy (4x4 Gy; BED 37 Gy), or a single 16 Gy dose (16 Gy; BED 100 Gy). Mice were sacrificed 2 weeks after the initial radiation exposure. The 16 Gy, but not 4x4 Gy, decreased total muscle protein and RNA content. Related to muscle regeneration, both 16 Gy and 4x4 Gy increased the incidence of central nuclei containing myofibers, but only 16 Gy increased the extracellular matrix volume. However, only 4x4 Gy increased muscle 4-hydroxynonenal expression. While both 16 Gy and 4x4 Gy decreased IIB myofiber mean cross-sectional area (CSA), only 16 Gy decreased IIA myofiber CSA. 16 Gy increased the incidence of small diameter IIA and IIB myofibers, while 4x4 Gy only increased the incidence of small diameter IIB myofibers. Both treatments decreased the frequency and CSA of low succinate dehydrogenase activity (SDH) fibers. Only 16 Gy increased the incidence of small diameter myofibers having high SDH activity. Neither treatment altered muscle signaling related to protein turnover or oxidative metabolism. Collectively, these results demonstrate that radiation dose differentially affects muscle remodeling, and these effects appear to be related to fiber type and oxidative metabolism

  12. Effective dose in abdominal digital radiography: Patient factor

    Energy Technology Data Exchange (ETDEWEB)

    Jang, Ji Sung; Koo, Hyun Jung; Park, Jung Hoon; Cho, Young Chul; Do, Kyung Hyun [Dept. of Radiology, and Research Institute of Radiology, Asan Medical Center, University of Ulsan College of Medicine, Seoul(Korea, Republic of); Yang, Hyung Jin [Dept. of Medical Physics, Korea University, Seoul (Korea, Republic of)

    2017-08-15

    To identify independent patient factors associated with an increased radiation dose, and to evaluate the effect of patient position on the effective dose in abdominal digital radiography. We retrospectively evaluated the effective dose for abdominal digital radiography in 222 patients. The patients were divided into two groups based on the cut-off dose value of 0.311 mSv (the upper third quartile of dose distribution): group A (n = 166) and group B (n = 56). Through logistic regression, independent factors associated with a larger effective dose were identified. The effect of patient position on the effective dose was evaluated using a paired t-test. High body mass index (BMI) (≥ 23 kg/m2), presence of ascites, and spinal metallic instrumentation were significantly associated with a larger effective dose. Multivariate logistic regression analysis revealed that high BMI [odds ratio (OR), 25.201; p < 0.001] and ascites (OR, 25.132; p < 0.001) were significantly associated with a larger effective dose. The effective dose was significantly lesser (22.6%) in the supine position than in the standing position (p < 0.001). High BMI and ascites were independent factors associated with a larger effective dose in abdominal digital radiography. Significant dose reduction in patients with these factors may be achieved by placing the patient in the supine position during abdominal digital radiography.

  13. The effect of dosing regimen on the pharmacokinetics of risedronate

    Science.gov (United States)

    Mitchell, David Y; Heise, Mark A; Pallone, Karen A; Clay, Marian E; Nesbitt, John D; Russell, Darrell A; Melson, Chad W

    1999-01-01

    Aims To examine the effect of timing of a risedronate dose relative to food intake on the rate and extent of risedronate absorption following single-dose, oral administration to healthy male and female volunteers. Methods A single-dose, randomized, parallel study design was conducted with volunteers assigned to four treatment groups (31 or 32 subjects per group, 127 subjects total). Each subject was orally administered 30 mg risedronate. Group 1 was fasted for 10 h prior to and 4 h after dosing (fasted group); Groups 2 and 3 were fasted for 10 h and were dosed 1 and 0.5 h, respectively, before a high-fat breakfast; and Group 4 was dosed 2 h after a standard dinner. Blood and urine samples were collected for 168 h after dosing. Pharmacokinetic parameters were estimated by simultaneous analysis of risedronate serum concentration and urinary excretion rate-time data. Results Extent of risedronate absorption (AUC and Ae) was comparable (P = 0.4) in subjects dosed 2 h after dinner and 0.5 h before breakfast; however, a significantly greater extent of absorption occurred when risedronate was given 1 or 4 h prior to a meal (1.4- to 2.3-fold greater). Administration 0.5, 1, or 4 h prior to a meal resulted in a significantly greater rate of absorption (Cmax 2.8-, 3.5-, and 4.1-fold greater, respectively) when compared with 2 h after dinner. Conclusions The comparable extent of risedronate absorption when administered either 0.5–1 h before breakfast or 2 h after an evening meal support previous clinical studies where risedronate was found to have similar effectiveness using these dosing regimens. This flexibility in the timing of risedronate administration may provide patients an alternative means to achieve the desired efficacy while maintaining their normal daily routine. PMID:10583024

  14. Late effects of low doses and dose rates

    International Nuclear Information System (INIS)

    Paretzke, H.G.

    1980-01-01

    This paper outlines the spectrum of problems and approaches used in work on the derivation of quantitative prognoses of late effects in man of low doses and dose rates. The origins of principal problems encountered in radiation risks assessments, definitions and explanations of useful quantities, methods of deriving risk factors from biological and epidemiological data, and concepts of risk evaluation and problems of acceptance are individually discussed

  15. Effective dose delivered by conventional radiology to Aosta Valley population between 2002 and 2009

    Science.gov (United States)

    Zenone, F; Aimonetto, S; Catuzzo, P; Peruzzo Cornetto, A; Marchisio, P; Natrella, M; Rosanò, A M; Meloni, T; Pasquino, M; Tofani, S

    2012-01-01

    Objective Medical diagnostic procedures can be considered the main man-made source of ionising radiation exposure for the population. Conventional radiography still represents the largest contribution to examination frequency. The present work evaluates procedure frequency and effective dose from the majority of conventional radiology examinations performed at the Radiological Department of Aosta Hospital from 2002 to 2009. Method Effective dose to the patient was evaluated by means of the software PCXMC. Data provided by the radiological information system allowed us to obtain collective effective and per caput dose. Results The biggest contributors to per caput effective dose from conventional radiology are vertebral column, abdomen, chest, pelvis and (limited to females) breast. Vertebral column, pelvis and breast procedures show a significant dose increment in the period of the study. The mean effective dose per inhabitant from conventional radiology increased from 0.131 mSv in 2002 to 0.156 mSv in 2009. Combining these figures with those from our study of effective dose from CT (0.55 mSv in 2002 to 1.03 mSv in 2009), the total mean effective dose per inhabitant increased from 0.68 mSv to 1.19 mSv. The contribution of CT increased from 81% to 87% of the total. In contrast, conventional radiology accounts for 85% of the total number of procedures, but only 13% of the effective dose. Conclusion The study has demonstrated that conventional radiography still represents the biggest contributor to examination frequency in Aosta Valley in 2009. However, the frequency of the main procedures did not change significantly between 2002 and 2009. PMID:21937611

  16. A fixed-dose approach to conducting emamectin benzoate tolerance assessments on field-collected sea lice, Lepeophtheirus salmonis.

    Science.gov (United States)

    Whyte, S K; Westcott, J D; Elmoslemany, A; Hammell, K L; Revie, C W

    2013-03-01

    In New Brunswick, Canada, the sea louse, Lepeophtheirus salmonis, poses an on-going management challenge to the health and productivity of commercially cultured Atlantic salmon, Salmo salar. While the in-feed medication, emamectin benzoate (SLICE® ; Merck), has been highly effective for many years, evidence of increased tolerance has been observed in the field since late 2008. Although bioassays on motile stages are a common tool to monitor sea lice sensitivity to emamectin benzoate in field-collected sea lice, they require the collection of large numbers of sea lice due to inherent natural variability in the gender and stage response to chemotherapeutants. In addition, sensitive instruments such as EC(50) analysis may be unnecessarily complex to characterize susceptibility subsequent to a significant observed decline in efficacy. This study proposes an adaptation of the traditional, dose-response format bioassay to a fixed-dose method. Analysis of 657 bioassays on preadult and adult stages of sea lice over the period 2008-2011 indicated a population of sea lice in New Brunswick with varying degrees of susceptibility to emamectin benzoate. A seasonal and spatial effect was observed in the robustness of genders and stages of sea lice, which suggest that mixing different genders and stages of lice within a single bioassay may result in pertinent information being overlooked. Poor survival of adult female lice in bioassays, particularly during May/June, indicates it may be prudent to consider excluding this stage from bioassays conducted at certain times of the year. This work demonstrates that fixed-dose bioassays can be a valuable technique in detecting reduced sensitivity in sea lice populations with varying degrees of susceptibility to emamectin benzoate treatments. © 2013 Blackwell Publishing Ltd.

  17. The estimation of radiation effective dose from diagnostic medical procedures in general population of northern Iran

    International Nuclear Information System (INIS)

    Shabestani Monfared, A.; Abdi, R.

    2006-01-01

    The risks of low-dose Ionizing radiation from radiology and nuclear medicine are not clearly determined. Effective dose to population is a very important factor in risk estimation. The study aimed to determine the effective dose from diagnostic radiation medicine in a northern province of Iran. Materials and Methods: Data about various radiologic and nuclear medicine procedures were collected from all radiology and nuclear medicine departments In Mazandaran Province (population = 2,898,031); and using the standard dosimetry tables, the total dose, dose per examination, and annual effective dose per capita as well as the annual gonadal dose per capita were estimated. Results: 655,730 radiologic examinations in a year's period, lead to 1.45 mSv, 0.33 mSv and 0.31 mGy as average effective dose per examination, annual average effective dose to member of the public, and annual average gonadal dose per capita, respectively. The frequency of medical radiologic examinations was 2,262 examinations annually per 10,000 members of population. However, the total number of nuclear medicine examinations in the same period was 7074, with 4.37 mSv, 9.6 μSv and 9.8 μGy, as average effective dose per examination, annual average effective dose to member of the public and annual average gonadal dose per caput, respectively. The frequency of nuclear medicine examination was 24 examinations annually per 10,000 members of population. Conclusion: The average effective dose per examination was nearly similar to other studies. However, the average annual effective dose and annual average gonadal dose per capita were less than the similar values in other reports, which could be due to lesser number of radiation medicine examinations in the present study

  18. An Improved Methodology of Monetary Values of the Unit Collective Dose for Intervention Against Long-Term Exposure Following a Nuclear Accident

    International Nuclear Information System (INIS)

    Hwang, Won Tae; Kim, Eun Han; Suh, Kyung Suk; Choi, Young Gil; Han, Moon Hee

    2002-01-01

    A more practice approach for the determination of monetary values of the unit collective dose for intervention against long-term exposure following a nuclear accident was proposed. In addition, the monetary values of the unit collective dose estimated from the proposed approach were compared with those estimated from the previous model, which are derived from assumptions of routine exposure and the same values are applied in a nuclear accident without modification, using Korea economic data. The monetary values based on the proposed approach showed a distinct difference depending on inequity in the distribution of individual doses. The discounting rate was also an important factor in determination of monetary values of the unit collective dose

  19. An Improved Methodology of Monetary Values of the Unit Collective Dose for Intervention Against Long-Term Exposure Following a Nuclear Accident

    Energy Technology Data Exchange (ETDEWEB)

    Hwang, Won Tae; Kim, Eun Han; Suh, Kyung Suk; Choi, Young Gil; Han, Moon Hee [KAERI, Daejeon (Korea, Republic of)

    2002-06-15

    A more practice approach for the determination of monetary values of the unit collective dose for intervention against long-term exposure following a nuclear accident was proposed. In addition, the monetary values of the unit collective dose estimated from the proposed approach were compared with those estimated from the previous model, which are derived from assumptions of routine exposure and the same values are applied in a nuclear accident without modification, using Korea economic data. The monetary values based on the proposed approach showed a distinct difference depending on inequity in the distribution of individual doses. The discounting rate was also an important factor in determination of monetary values of the unit collective dose.

  20. Comparative analysis of collective doses received since 1976 at the Ardennes nuclear power plant

    International Nuclear Information System (INIS)

    Aye, Louis

    1980-01-01

    The analysis of the collective doses at the Centrale nucleaire des Ardennes povides valuable data about the origin of exposures in P.W.R. reactors and their evolution regarding the increase of activity of the circuits after more than 10 years of operation. The investigations led for most of the works since 1976 reveals that, in some cases, the use of sophisticated implements combined with modifications of equipments and procedures may bring appreciable savings on doses during normal operation as well as maintenance and refuelings shut-down. However, the study gives the 'reasonably achievable' limits than can be aimed in a plant on operation, the doses resulting mainly from problems that should be taken into account at design [fr

  1. We can do better than effective dose for estimating or comparing low-dose radiation risks

    International Nuclear Information System (INIS)

    Brenner, D.J.

    2012-01-01

    The effective dose concept was designed to compare the generic risks of exposure to different radiation fields. More commonly these days, it is used to estimate or compare radiation-induced cancer risks. For various reasons, effective dose represents flawed science: for instance, the tissue-specific weighting factors used to calculate effective dose are a subjective mix of different endpoints; and the marked and differing age and gender dependencies for different health detriment endpoints are not taken into account. This paper suggests that effective dose could be replaced with a new quantity, ‘effective risk’, which, like effective dose, is a weighted sum of equivalent doses to different tissues. Unlike effective dose, where the tissue-dependent weighting factors are a set of generic, subjective committee-defined numbers, the weighting factors for effective risk are simply evaluated tissue-specific lifetime cancer risks per unit equivalent dose. Effective risk, which has the potential to be age and gender specific if desired, would perform the same comparative role as effective dose, be just as easy to estimate, be less prone to misuse, be more directly understandable, and would be based on solid science. An added major advantage is that it gives the users some feel for the actual numerical values of the radiation risks they are trying to control.

  2. Biochemical and cellular mechanisms of low-dose effects

    International Nuclear Information System (INIS)

    Feinendegen, L.E.; Booz, J.; Muehlensiepen, H.

    1988-01-01

    The question of health effects from small radiation doses remains open. Individual cells, when being hit by single elemental doses - in low-dose irradiation - react acutely and temporarily by altering control of enzyme activity, as is demonstrated for the case of thymidine kinase. This response is not constant in that it provides a temporary protection of enzyme activity against a second irradiation, by a mechanism likely to be via improved detoxification of intracellular radicals. It must be considered that in the low-dose region radiation may also exert protection against other challenges involving radicals, causing a net beneficial effect by temporarily shielding the hit cell against radicals produced by metabolism. Since molecular alterations leading to late effects are considered a consequence of the initial cellular response, late effects from small radiation doses do not necessarily adhere to a linear dose-effect relationship. The reality of the linear relationship between the risk of late effects from high doses to small doses is an assumption, for setting dose limits, but it must not be taken for predicting health detriment from low doses. (author)

  3. Age-dependent conversion coefficients for organ doses and effective doses for external neutron irradiation

    International Nuclear Information System (INIS)

    Nishizaki, Chihiro; Endo, Akira; Takahashi, Fumiaki

    2006-06-01

    To utilize dose assessment of the public for external neutron irradiation, conversion coefficients of absorbed doses of organs and effective doses were calculated using the numerical simulation technique for six different ages (adult, 15, 10, 5 and 1 years and newborn), which represent the member of the public. Calculations were performed using six age-specific anthropomorphic phantoms and a Monte Carlo radiation transport code for two irradiation geometries, anterior-posterior and rotational geometries, for 20 incident energies from thermal to 20 MeV. Effective doses defined by the 1990 Recommendation of ICRP were calculated from the absorbed doses in 21 organs. The calculated results were tabulated in the form of absorbed doses and effective doses per unit neutron fluence. The calculated conversion coefficients are used for dose assessment of the public around nuclear facilities and accelerator facilities. (author)

  4. The concept of the effective dose

    International Nuclear Information System (INIS)

    Jacobi, W.

    1975-01-01

    Irradiation of the human body by external or internal sources leads mostly to a simultaneous exposure of several organs. However, so far no clear and consistent recommendations for the combination of organ doses and the assessment of an exposure limit under such irradiation conditions are available. Following a proposal described in ICRP-publication 14 one possible concept for the combination of organ doses is discussed in this paper. This concept is based on the assumption that at low doses the total radiation detriment to the exposed person is given by the sum of radiation detriments to the single organs. Taking into account a linear dose-risk relationship, the sum of weighted organ doses leads to the definition of an 'Effective Dose'. The applicability and consequences of this 'Effective Dose Concept' are discussed especially with regard to the assessment of the maximum permissible intake of radionuclides into the human body and the combination of external and internal exposure. (orig.) [de

  5. Effective radiation dose and eye lens dose in dental cone beam CT: effect of field of view and angle of rotation.

    Science.gov (United States)

    Pauwels, R; Zhang, G; Theodorakou, C; Walker, A; Bosmans, H; Jacobs, R; Bogaerts, R; Horner, K

    2014-10-01

    To quantify the effect of field of view (FOV) and angle of rotation on radiation dose in dental cone beam CT (CBCT) and to define a preliminary volume-dose model. Organ and effective doses were estimated using 148 thermoluminescent dosemeters placed in an anthropomorphic phantom. Dose measurements were undertaken on a 3D Accuitomo 170 dental CBCT unit (J. Morita, Kyoto, Japan) using six FOVs as well as full-rotation (360°) and half-rotation (180°) protocols. For the 360° rotation protocols, effective dose ranged between 54 µSv (4 × 4 cm, upper canine) and 303 µSv (17 × 12 cm, maxillofacial). An empirical relationship between FOV dimension and effective dose was derived. The use of a 180° rotation resulted in an average dose reduction of 45% compared with a 360° rotation. Eye lens doses ranged between 95 and 6861 µGy. Significant dose reduction can be achieved by reducing the FOV size, particularly the FOV height, of CBCT examinations to the actual region of interest. In some cases, a 180° rotation can be preferred, as it has the added value of reducing the scan time. Eye lens doses should be reduced by decreasing the height of the FOV rather than using inferior FOV positioning, as the latter would increase the effective dose considerably. The effect of the FOV and rotation angle on the effective dose in dental CBCT was quantified. The dominant effect of FOV height was demonstrated. A preliminary model has been proposed, which could be used to predict effective dose as a function of FOV size and position.

  6. Effects of low doses; Effet des faibles doses

    Energy Technology Data Exchange (ETDEWEB)

    Le Guen, B. [Electricite de France (EDF-LAM-SCAST), 93 - Saint-Denis (France)

    2001-07-01

    Actually, even though it is comfortable for the risk management, the hypothesis of the dose-effect relationship linearity is not confirmed for any model. In particular, in the area of low dose rate delivered by low let emitters. this hypothesis is debated at the light of recent observations, notably these ones relative to the mechanisms leading to genetic instability and induction eventuality of DNA repair. The problem of strong let emitters is still to solve. (N.C.)

  7. Therapeutic effects of low radiation doses

    Energy Technology Data Exchange (ETDEWEB)

    Trott, K.R. (Dept. of Radiation Biology, St. Bartholomew' s Medical College, London (United Kingdom))

    1994-01-01

    This editorial explores the scientific basis of radiotherapy with doses of < 1 Gy for various non-malignant conditions, in particular dose-effect relationships, risk-benefit considerations and biological mechanisms. A review of the literature, particularly clinical and experimental reports published more than 50 years ago was conducted to clarify the following problems. 1. The dose-response relationships for the therapeutic effects on three groups of conditions: non-malignant skin disease, arthrosis and other painful degenerative joint disorders and anti-inflammatory radiotherapy; 2. risks after radiotherapy and after the best alternative treatments; 3. the biological mechanisms of the different therapeutic effects. Radiotherapy is very effective in all three groups of disease. Few dose-finding studies have been performed, all demonstrating that the optimal doses are considerable lower than the generally recommended doses. In different conditions, risk-benefit analysis of radiotherapy versus the best alternative treatment yields very different results: whereas radiotherapy for acute postpartum mastitis may not be justified any more, the risk-benefit ratio of radiotherapy of other conditions and particularly so in dermatology and some anti-inflammatory radiotherapy appears to be more favourable than the risk-benefit ratio of the best alternative treatments. Radiotherapy can be very effective treatment for various non-malignant conditions such as eczema, psoriasis, periarthritis humeroscapularis, epicondylitis, knee arthrosis, hydradenitis, parotitis and panaritium and probably be associated with less acute and long-term side effects than similarly effective other treatments. Randomized clinical studies are required to find the optimal dosage which, at present, may be unnecessarily high.

  8. Doses from nuclear medicine examinations: A 25-year follow-up study

    International Nuclear Information System (INIS)

    Kairemo, K.J.A.; Korpela, H.

    2001-01-01

    New radiopharmaceuticals have been introduced in nuclear medicine examinations, and on the other hand, the amount of many routine nuclear medicine procedures have been replaced with clinical methods utilising non-ionisating radiation (ultrasonography, MRI). To clarify the situation in Finland, a country wide survey on the use of radiopharmaceuticals in diagnostics and therapy was made in 1975, 1982, 1989, 1994, 1997 and will be made in 2000. A questionnaire was sent to all hospitals and institutes using unsealed sources in both diagnostic and therapeutic nuclear medicine procedures. For each procedure, the pharmaceutical used, the number of procedures and the typical administered activities were recorded. The collective effective doses from nuclear medicine examinations were calculated according to the ICRP formulae similarly for each survey. In Finland, in each of these years, more than 50,000 procedures in more than 30 different laboratories were performed. Significant changes in collective doses were observed: for example, the collective dose from I-131 was 350 manSv in 1975, and 20 manSv in 1997. In 1975, 68% (n=23967) of collective dose originated from I-131, whereas in 1997 the percentage of I-131 in collective dose was 10 % (n=1118). In 1994 and 1997, the use of the three radionuclides (Tc-99m, I-131 and Tl-201) accounted for 96% and 95% of the collective effective dose. Our results indicate that the collective effective dose from nuclear medicine examinations has decreased in last 25 years. National surveys form the basis when setting reference levels for typical nuclear medicine examinations. By introducing reference levels based on national practice it is possible to even decrease the collective effective dose. (author)

  9. Effects of small doses of ionising radiation

    International Nuclear Information System (INIS)

    Doll, R.

    1998-01-01

    Uncertainty remains about the quantitative effects of doses of ionising radiation less than 0.2 Sv. Estimates of hereditary effects, based on the atomic bomb survivors, suggest that the mutation doubling dose is about 2 Sv for acute low LET radiation, but the confidence limits are wide. The idea that paternal gonadal irradiation might explain the Seascale cluster of childhood leukaemia has been disproved. Fetal irradiation may lead to a reduction in IQ and an increase in seizures in childhood proportional to dose. Estimates that doses to a whole population cause a risk of cancer proportional to dose, with 0.1 Sv given acutely causing a risk of 1%, will need to be modified as more information is obtained, but the idea that there is a threshold for risk above this level is not supported by observations on the irradiated fetus or the effect of fallout. The idea, based on ecological observations, that small doses protect against the development of cancer is refuted by the effect of radon in houses. New observations on the atomic bomb survivors have raised afresh the possibility that small doses may also have other somatic effects. (author)

  10. adverse effects of low dose methotrexate in rheumatoid arthritis patients

    International Nuclear Information System (INIS)

    Gilani, S.T.; Khan, D.A.; Khan, F.A.; Ahmed, M.

    2012-01-01

    To determine the frequency of adverse effects attributed to Methotrexate (MTX) toxicity and serum minimum toxic concentration with low dose MTX in Rheumatoid Arthritis (RA) patients. Study Design: Cross-sectional observational study. Place and Duration of Study: Department of Chemical Pathology and Endocrinology, Armed Forces Institute of Pathology, Rawalpindi, from March 2010 to March 2011. Methodology: One hundred and forty adult patients of RA receiving low dose MTX (10 mg/week) for at least 3 months, ere included by consecutive sampling. Blood samples were collected 2 hours after the oral dose of MTX. Serum alanine transaminase and creatinine were analyzed on Hitachi and blood counts on Sysmex analyzer. Serum MTX concentration was measured on TDX analyzer. Results: Out of one hundred and forty patients; 68 males (49%) and 72 females (51%), 38 developed MTX toxicity (27%), comprising of hepatotoxicity in 12 (8.6%), nephrotoxicity in 3 (2.1%), anaemia in 8 (5.7%), leucopenia in 2 (1.4%), thrombocytopenia in 3 (2.1%), pancytopenia in 2 (1.4%), gastrointestinal adverse effects in 5 (3.6%) and mucocutaneous problems in 3 (2.1%). Receiver operating characteristic curve revealed serum minimum toxic concentration of MTX at cutoff value of 0.71 mu mol/l with a sensitivity of 71% and specificity of 76%. Conclusion: Adverse effects of low dose MTX were found in 27% of RA patients, mainly comprising of hepatotoxicity and haematological problems. MTX toxicity can be detected by therapeutic drug monitoring of serum concentration of 0.71 mu mol/l with sensitivity of 71% and specificity of 76% in the patients on low dose MTX maintenance therapy. (author)

  11. Estimating collective dose in nuclear facilities, with emphasis on the design process

    International Nuclear Information System (INIS)

    Cohen, S.; Mann, B.

    1987-01-01

    The report presents a more accurate, systematic method than has been available previously for predicting worker doses which might be incurred during routine and non-routine work in radioactive areas. Besides assisting regulators with an analysis of the ''potential impact on radiological exposures of facility employees'' now required under the new backfit rule (10 CFR 50.109c), this predictive model will also help licensees conserve dollars as well as dose because it can be employed very early in the engineering design phase of a modification, when adjustments can still be made easily to change orders. Such early estimates make good business sense because they will facilitate planning, labor loading, costing, resource and equipment scheduling, and overall coordination of both single and repetitive projects. Also, with the support of corporate management, radiation protection coordinators can introduce the model into training programs to acquaint design engineers and others with dose calculation techniques. The importance assigned by nuclear industry senior management to the principle of ALARA and the reduction of collective worker dose is measured, in large part, by demonstrated efforts to integrate the control of radiation exposure fully into the overall planning function of nuclear facility management. That integration will be fostered through the use of this approach

  12. Effects of different premature chromosome condensation method on dose-curve of 60Co γ-ray

    International Nuclear Information System (INIS)

    Guo Yicao; Yang Haoxian; Yang Yuhua; Li Xi'na; Huang Weixu; Zheng Qiaoling

    2012-01-01

    Objective: To study the effect of traditional method and improved method of the premature chromosome condensation (PCC) on the dose-effect curve of 60 Co γ ray, for choosing the rapid and accurate biological dose estimating method for the accident emergency. Methods: Collected 3 healthy male cubits venous blood (23 to 28 years old), and irradiated by 0, 1.0, 5.0, 10.0, 15.0, 20.0 Gy 60 Co γ ray (absorbed dose rate: 0.635 Gy/min). Observed the relation of dose-effect curve in the 2 incubation time (50 hours and 60 hours) of the traditional method and improved method. Used the dose-effect curve to verify the exposure of 10.0 Gy (absorbed dose rate: 0.670 Gy/min). Results: (1) In the traditional method of 50-hour culture, the PCC cell count in 15.0 Gy and 20.0 Gy was of no statistical significance. But there were statistical significance in the traditional method of 60-hours culture and improved method (50-hour culture and 60-hour culture). Used the last 3 culture methods to make dose curve. (2) In the above 3 culture methods, the related coefficient between PCC ring and exposure dose was quite close (all of more than 0.996, P 0.05), the morphology of regression straight lines almost overlap. (3) Used the above 3 dose-effect curves to estimate the irradiation results (10.0 Gy), the error was less than or equal to 8%, all of them were within the allowable range of the biological experiment (15%). Conclusion: The 3 dose-effect curves of the above 3 culture methods can apply to biological dose estimating of large doses of ionizing radiation damage. Especially the improved method of 50-hour culture,it is much faster to estimate and it should be regarded as the first choice in accident emergency. (authors)

  13. Effective dose evaluation of NORM-added consumer products using Monte Carlo simulations and the ICRP computational human phantoms

    International Nuclear Information System (INIS)

    Lee, Hyun Cheol; Yoo, Do Hyeon; Testa, Mauro; Shin, Wook-Geun; Choi, Hyun Joon; Ha, Wi-Ho; Yoo, Jaeryong; Yoon, Seokwon; Min, Chul Hee

    2016-01-01

    The aim of this study is to evaluate the potential hazard of naturally occurring radioactive material (NORM) added consumer products. Using the Monte Carlo method, the radioactive products were simulated with ICRP reference phantom and the organ doses were calculated with the usage scenario. Finally, the annual effective doses were evaluated as lower than the public dose limit of 1 mSv y"−"1 for 44 products. It was demonstrated that NORM-added consumer products could be quantitatively assessed for the safety regulation. - Highlights: • Consumer products considered that NORM would be included should be regulated. • 44 products were collected and its gamma activities were measured with HPGe detector. • Through Monte Carlo simulation, organ equivalent doses and effective doses on human phantom were calculated. • All annual effective doses for the products were evaluated as lower than dose limit for the public.

  14. Relation between dose of bendrofluazide, antihypertensive effect, and adverse biochemical effects

    DEFF Research Database (Denmark)

    Carlsen, J E; Køber, L; Torp-Pedersen, C

    1990-01-01

    OBJECTIVE--To determine the relevant dose of bendrofluazide for treating mild to moderate hypertension. DESIGN--Double blind parallel group trial of patients who were given placebo for six weeks and then randomly allocated to various doses of bendrofluazide (1.25, 2.5, 5, or 10 mg daily) or place...... of bendrofluazide to treat mild to moderate hypertension is 1.25-2.5 mg a day. Higher doses caused more pronounced adverse biochemical effects including adverse lipid effects. Previous trials with bendrofluazide have used too high doses....... relations between dose and effect were shown for potassium, urate, glucose, total cholesterol, and apolipoprotein B concentrations. The 1.25 mg dose increased only urate concentrations, whereas the 10 mg dose affected all the above biochemical variables. CONCLUSION--The relevant range of doses...

  15. Effect of edema, relative biological effectiveness, and dose heterogeneity on prostate brachytherapy

    International Nuclear Information System (INIS)

    Wang, Jian Z.; Mayr, Nina A.; Nag, Subir; Montebello, Joseph; Gupta, Nilendu; Samsami, Nina; Kanellitsas, Christos

    2006-01-01

    Many factors influence response in low-dose-rate (LDR) brachytherapy of prostate cancer. Among them, edema, relative biological effectiveness (RBE), and dose heterogeneity have not been fully modeled previously. In this work, the generalized linear-quadratic (LQ) model, extended to account for the effects of edema, RBE, and dose heterogeneity, was used to assess these factors and their combination effect. Published clinical data have shown that prostate edema after seed implant has a magnitude (ratio of post- to preimplant volume) of 1.3-2.0 and resolves exponentially with a half-life of 4-25 days over the duration of the implant dose delivery. Based on these parameters and a representative dose-volume histogram (DVH), we investigated the influence of edema on the implant dose distribution. The LQ parameters (α=0.15 Gy -1 and α/β=3.1 Gy) determined in earlier studies were used to calculate the equivalent uniform dose in 2 Gy fractions (EUD 2 ) with respect to three effects: edema, RBE, and dose heterogeneity for 125 I and 103 Pd implants. The EUD 2 analysis shows a negative effect of edema and dose heterogeneity on tumor cell killing because the prostate edema degrades the dose coverage to tumor target. For the representative DVH, the V 100 (volume covered by 100% of prescription dose) decreases from 93% to 91% and 86%, and the D 90 (dose covering 90% of target volume) decrease from 107% to 102% and 94% of prescription dose for 125 I and 103 Pd implants, respectively. Conversely, the RBE effect of LDR brachytherapy [versus external-beam radiotherapy (EBRT) and high-dose-rate (HDR) brachytherapy] enhances dose effect on tumor cell kill. In order to balance the negative effects of edema and dose heterogeneity, the RBE of prostate brachytherapy was determined to be approximately 1.2-1.4 for 125 I and 1.3-1.6 for 103 Pd implants. These RBE values are consistent with the RBE data published in the literature. These results may explain why in earlier modeling studies

  16. Dosimetry in Interventional Radiology - Effective Dose Estimation

    International Nuclear Information System (INIS)

    Miljanic, S.; Buls, N.; Clerinx, P.; Jarvinen, H.; Nikodemova, D.; Ranogajec-Komor, M; D'Errico, F.

    2008-01-01

    Interventional radiological procedures can lead to significant radiation doses to patients and to staff members. In order to evaluate the personal doses with respect to the regulatory dose limits, doses measured by dosimeters have to be converted to effective doses (E). Measurement of personal dose equivalent Hp(10) using a single unshielded dosimeter above the lead apron can lead to significant overestimation of the effective dose, while the measurement with dosimeter under the apron can lead to underestimation. To improve the accuracy, measurements with two dosimeters, one above and the other under the apron have been suggested ( d ouble dosimetry ) . The ICRP has recommended that interventional radiology departments develop a policy that staff should wear two dosimeters. The aim of this study was to review the double dosimetry algorithms for the calculation of effective dose in high dose interventional radiology procedures. The results will be used to develop general guidelines for personal dosimetry in interventional radiology procedures. This work has been carried out by Working Group 9 (Radiation protection dosimetry of medical staff) of the CONRAD project, which is a Coordination Action supported by the European Commission within its 6th Framework Program.(author)

  17. Equivalent dose, effective dose and risk assessment from cephalometric radiography to critical organs

    International Nuclear Information System (INIS)

    Kang, Seong Sook; Cho, Bon Hae; Kim, Hyun Ja

    1995-01-01

    In head and neck region, the critical organ and tissue doses were determined, and the risks were estimated from lateral, posteroanterial and basilar cephalometric radiography. For each cephalometric radiography, 31 TLDs were placed in selected sites (18 internal and 13 external sites) in a tissue-equivalent phantom and exposed, then read-out in the TLD reader. The following results were obtained; 1. From lateral cephalometric radiography, the highest effective dose recorded was that delivered to the salivary gland (3.6 μSv) and the next highest dose was that received by the bone marrow (3 μSv). 2. From posteroanterial cephalometric radiography, the highest effective dose recorded was that delivered to the salivary gland (2 μSv) and the next highest dose was that received by the bone marrow (1.8 μSv). 3. From basilar cephalometric radiography, the highest effective dose recorded was that delivered to the thyroid gland (31.4 μSv) and the next highest dose was that received by the salivary gland (13.3 μSv). 4. The probabilities of stochastic effect from lateral, posteroanterial and basilar cephalometric radiography were 0.72 X 10 -6 , 0.49 X 10 -6 and 3.51 X 10 -6 , respectively.

  18. Analysis of occupational doses of workers on the dose registry of the Federal Radiation Protection Service in 2000 and 2001

    International Nuclear Information System (INIS)

    Ogundare, F.O.; Balogun, F.A.

    2003-01-01

    In 2000 and 2001 about 279 and 221 radiation workers, respectively, were monitored by the Federal Radiation Protection Service, University of Ibadan, in Nigeria. The distribution of the occupational doses shows that the majority of workers received doses below 4 mSv in each of the two years. The radiation workers in the two years are classified into two occupational categories: medicine and industry. The mean annual effective doses, collective doses and the collective dose distribution ratios for workers in each category and the entire monitored workers were calculated. The mean annual effective doses were compared with their corresponding worldwide values quoted by UNSCEAR. In each of the two years, a few workers in industry received doses higher than 50 mSv. The collective dose distribution ratio was found to be about 0.49, which is very close to the highest value of 0.5 in the range of values considered by UNSCEAR as normal for this parameter. This suggests that extra measures have to be taken, particularly in industry, to ensure that the proportion of workers at risk does not go outside this normal range. The occupational doses were also modelled by both the log-normal and Weibull distributions. Both distributions were found to describe the data in almost the same way. (author)

  19. Effective dose: a radiation protection quantity

    CERN Document Server

    Menzel, H G

    2012-01-01

    Modern radiation protection is based on the principles of justification, limitation, and optimisation. Assessment of radiation risks for individuals or groups of individuals is, however, not a primary objective of radiological protection. The implementation of the principles of limitation and optimisation requires an appropriate quantification of radiation exposure. The International Commission on Radiological Protection (ICRP) has introduced effective dose as the principal radiological protection quantity to be used for setting and controlling dose limits for stochastic effects in the regulatory context, and for the practical implementation of the optimisation principle. Effective dose is the tissue weighted sum of radiation weighted organ and tissue doses of a reference person from exposure to external irradiations and internal emitters. The specific normalised values of tissue weighting factors are defined by ICRP for individual tissues, and used as an approximate age- and sex-averaged representation of th...

  20. Low-dose effects of hormones and endocrine disruptors.

    Science.gov (United States)

    Vandenberg, Laura N

    2014-01-01

    Endogenous hormones have effects on tissue morphology, cell physiology, and behaviors at low doses. In fact, hormones are known to circulate in the part-per-trillion and part-per-billion concentrations, making them highly effective and potent signaling molecules. Many endocrine-disrupting chemicals (EDCs) mimic hormones, yet there is strong debate over whether these chemicals can also have effects at low doses. In the 1990s, scientists proposed the "low-dose hypothesis," which postulated that EDCs affect humans and animals at environmentally relevant doses. This chapter focuses on data that support and refute the low-dose hypothesis. A case study examining the highly controversial example of bisphenol A and its low-dose effects on the prostate is examined through the lens of endocrinology. Finally, the chapter concludes with a discussion of factors that can influence the ability of a study to detect and interpret low-dose effects appropriately. © 2014 Elsevier Inc. All rights reserved.

  1. UV-radiation and skin cancer dose effect curves

    International Nuclear Information System (INIS)

    Henriksen, T.; Dahlback, A.; Larsen, S.H.

    1988-08-01

    Norwegian skin cancer data were used in an attempt to arrive at the dose effect relationship for UV-carcinogenesis. The Norwegian population is relatively homogenous with regard to skin type and live in a country where the annual effective UV-dose varies by approximately 40 percent. Four different regions of the country, each with a broadness of 1 o in latitude (approximately 111 km), were selected . The annual effective UV-doses for these regions were calculated assuming normal ozone conditions throughout the year. The incidence of malignant melanoma and non-melanoma skin cancer (mainly basal cell carcinoma) in these regions were considered and compared to the annual UV-doses. For both these types of cancer a quadratic dose effect curve seems to be valid. Depletions of the ozone layer results in larger UV-doses which in turn may yield more skin cancer. The dose effect curves suggest that the incidence rate will increase by an ''amplification factor'' of approximately 2

  2. Evaluation of the effective dose equivalent to tbe public of Pavia after the Chernobyl nuclear accident

    International Nuclear Information System (INIS)

    Altieri, S.; Berzero, A.; Meloni, S.; Rosti, G.; Genova, N.

    1988-01-01

    The Chernobyl radionuclide monitoring campaign in air particulate and foodstuffs was carried out and continued up to June 1987. On the basis of collected data estimates of the collective effective dose equivalent commitment to the public of province of Pavia, by external irradiation or by inhalation, were carried out and are reported in the present paper

  3. Multidetector CT radiation dose optimisation in adults: short- and long-term effects of a clinical audit

    International Nuclear Information System (INIS)

    Tack, Denis; Jahnen, Andreas; Kohler, Sarah; Harpes, Nico; Back, Carlo; Maertelaer, Viviane de; Gevenois, Pierre Alain

    2014-01-01

    To report short- and long-term effects of an audit process intended to optimise the radiation dose from multidetector row computed tomography (MDCT). A survey of radiation dose from all eight MDCT departments in the state of Luxembourg performed in 2007 served as baseline, and involved the most frequently imaged regions (head, sinus, cervical spine, thorax, abdomen, and lumbar spine). CT dose index volume (CTDIvol), dose-length product per acquisition (DLP/acq), and DLP per examination (DLP/exa) were recorded, and their mean, median, 25th and 75th percentiles compared. In 2008, an audit conducted in each department helped to optimise doses. In 2009 and 2010, two further surveys evaluated the audit's impact on the dose delivered. Between 2007 and 2009, DLP/exa significantly decreased by 32-69 % for all regions (P < 0.001) except the lumbar spine (5 %, P = 0.455). Between 2009 and 2010, DLP/exa significantly decreased by 13-18 % for sinus, cervical and lumbar spine (P ranging from 0.016 to less than 0.001). Between 2007 and 2010, DLP/exa significantly decreased for all regions (18-75 %, P < 0.001). Collective dose decreased by 30 % and the 75th percentile (diagnostic reference level, DRL) by 20-78 %. The audit process resulted in long-lasting dose reduction, with DRLs reduced by 20-78 %, mean DLP/examination by 18-75 %, and collective dose by 30 %. (orig.)

  4. The relative biological effectiveness of out-of-field dose

    International Nuclear Information System (INIS)

    Balderson, Michael; Koger, Brandon; Kirkby, Charles

    2016-01-01

    Purpose: using simulations and models derived from existing literature, this work investigates relative biological effectiveness (RBE) for out-of-field radiation and attempts to quantify the relative magnitudes of different contributing phenomena (spectral, bystander, and low dose hypersensitivity effects). Specific attention is paid to external beam radiotherapy treatments for prostate cancer. Materials and methods: using different biological models that account for spectral, bystander, and low dose hypersensitivity effects, the RBE was calculated for different points moving radially out from isocentre for a typical single arc VMAT prostate case. The RBE was found by taking the ratio of the equivalent dose with the physical dose. Equivalent doses were calculated by determining what physical dose would be necessary to produce the same overall biological effect as that predicted using the different biological models. Results: spectral effects changed the RBE out-of-field less than 2%, whereas response models incorporating low dose hypersensitivity and bystander effects resulted in a much more profound change of the RBE for out-of-field doses. The bystander effect had the largest RBE for points located just outside the edge of the primary radiation beam in the cranial caudal (z-direction) compared to low dose hypersensitivity and spectral effects. In the coplanar direction, bystander effect played the largest role in enhancing the RBE for points up to 8.75 cm from isocentre. Conclusions: spectral, bystander, and low dose hypersensitivity effects can all increase the RBE for out-of-field radiation doses. In most cases, bystander effects seem to play the largest role followed by low dose hypersensitivity. Spectral effects were unlikely to be of any clinical significance. Bystander, low dose hypersensitivity, and spectral effect increased the RBE much more in the cranial caudal direction (z-direction) compared with the coplanar directions. (paper)

  5. Dose estimates in Japan following the Chernobyl reactor accident

    International Nuclear Information System (INIS)

    Togawa, Orihiko; Homma, Toshimitsu; Iijima, Toshinori; Midorikawa, Yuji.

    1988-02-01

    Estimates have been made of the maximum individual doses and the collective doses in Japan following the Chernobyl reactor accident. Based on the measured data of ground deposition and radionuclide concentrations in air, raw milk, milk on sale and leafy vegetables, the doses from some significant radionuclides were calculated for 5 typical exposure pathways; cloudshine, groundshine, inhalation, ingestion of milk and leafy vegetables. The maximum effective dose equivalents for hypothetical individuals were calculated to be 1.8 mrem for adults, 3.7 mrem for children and 6.0 mrem for infants. The collective effective dose equivalent in Japan was estimated to be 5.8 x 10 4 man · rem; 0.50 mrem of the average dose per capita. (author)

  6. Effects of low doses

    International Nuclear Information System (INIS)

    Le Guen, B.

    2001-01-01

    Actually, even though it is comfortable for the risk management, the hypothesis of the dose-effect relationship linearity is not confirmed for any model. In particular, in the area of low dose rate delivered by low let emitters. this hypothesis is debated at the light of recent observations, notably these ones relative to the mechanisms leading to genetic instability and induction eventuality of DNA repair. The problem of strong let emitters is still to solve. (N.C.)

  7. Assessment of the population effective dose from the diagnostic use of radiopharmaceuticals in Cuba

    International Nuclear Information System (INIS)

    Brigido, O.; Montalvan, A.

    2008-01-01

    In an attempt to estimate the effective collective dose imparted to the population of Camaguey, Ciego de Avila, Las Tunas and Holguin territory, Cuba, has been made use of statistic from nuclear medicine examinations given to a population of 1.1 million inhabitants for the years 1995 through 1999. The average annual frequency of examinations was estimated to be 3.82 per 1000 population. The results show that nuclear medicine techniques of thyroid explorations with 43.73% and iodide uptake with 43.36% are the main techniques implicated in the relative contribution to the total annual effective collective dose which averaged 54.43 man·Sv for the studied period. Radiation risks for the Camaguey-Ciego de Avila population caused by nuclear medicine examinations in the period studied were calculated: the total number of fatal and non-fatal cancers was 16.33 and the number of serious hereditary disturbance was 3.54 as a result of 21073 nuclear medicine procedures. (author)

  8. Dose and dose-rate effects of ionizing radiation: a discussion in the light of radiological protection

    Energy Technology Data Exchange (ETDEWEB)

    Ruehm, Werner [Helmholtz Zentrum Muenchen, German Research Center for Environmental Health, Institute of Radiation Protection, Neuherberg (Germany); Woloschak, Gayle E. [Northwestern University, Department of Radiation Oncology, Feinberg School of Medicine, Chicago, IL (United States); Shore, Roy E. [Radiation Effects Research Foundation (RERF), Hiroshima City (Japan); Azizova, Tamara V. [Southern Urals Biophysics Institute (SUBI), Ozyorsk, Chelyabinsk Region (Russian Federation); Grosche, Bernd [Federal Office for Radiation Protection, Oberschleissheim (Germany); Niwa, Ohtsura [Fukushima Medical University, Fukushima (Japan); Akiba, Suminori [Kagoshima University Graduate School of Medical and Dental Sciences, Department of Epidemiology and Preventive Medicine, Kagoshima City (Japan); Ono, Tetsuya [Institute for Environmental Sciences, Rokkasho, Aomori-ken (Japan); Suzuki, Keiji [Nagasaki University, Department of Radiation Medical Sciences, Atomic Bomb Disease Institute, Nagasaki (Japan); Iwasaki, Toshiyasu [Central Research Institute of Electric Power Industry (CRIEPI), Radiation Safety Research Center, Nuclear Technology Research Laboratory, Tokyo (Japan); Ban, Nobuhiko [Tokyo Healthcare University, Faculty of Nursing, Tokyo (Japan); Kai, Michiaki [Oita University of Nursing and Health Sciences, Department of Environmental Health Science, Oita (Japan); Clement, Christopher H.; Hamada, Nobuyuki [International Commission on Radiological Protection (ICRP), PO Box 1046, Ottawa, ON (Canada); Bouffler, Simon [Public Health England (PHE), Centre for Radiation, Chemical and Environmental Hazards, Chilton, Didcot (United Kingdom); Toma, Hideki [JAPAN NUS Co., Ltd. (JANUS), Tokyo (Japan)

    2015-11-15

    The biological effects on humans of low-dose and low-dose-rate exposures to ionizing radiation have always been of major interest. The most recent concept as suggested by the International Commission on Radiological Protection (ICRP) is to extrapolate existing epidemiological data at high doses and dose rates down to low doses and low dose rates relevant to radiological protection, using the so-called dose and dose-rate effectiveness factor (DDREF). The present paper summarizes what was presented and discussed by experts from ICRP and Japan at a dedicated workshop on this topic held in May 2015 in Kyoto, Japan. This paper describes the historical development of the DDREF concept in light of emerging scientific evidence on dose and dose-rate effects, summarizes the conclusions recently drawn by a number of international organizations (e.g., BEIR VII, ICRP, SSK, UNSCEAR, and WHO), mentions current scientific efforts to obtain more data on low-dose and low-dose-rate effects at molecular, cellular, animal and human levels, and discusses future options that could be useful to improve and optimize the DDREF concept for the purpose of radiological protection. (orig.)

  9. Dose-response effect of photobiomodulation therapy on neuromuscular economy during submaximal running.

    Science.gov (United States)

    Dellagrana, Rodolfo André; Rossato, Mateus; Sakugawa, Raphael Luiz; Lazzari, Caetano Decian; Baroni, Bruno Manfredini; Diefenthaeler, Fernando

    2018-02-01

    The purpose of this study was to verify the photobiomodulation therapy (PBMT) effects with different doses on neuromuscular economy during submaximal running tests. Eighteen male recreational runners participate in a randomized, double-blind, and placebo-controlled trial, which each participant was submitted to the same testing protocol in five conditions: control, placebo, and PBMT with doses of 15, 30, and 60 J per site (14 sites in each lower limb). The submaximal running was performed at 8 and 9 km h -1 during 5 min for each velocity. Muscle activation of the vastus lateralis (VL), vastus medialis (VM), rectus femoris (RF), biceps femoris (BF), and gastrocnemius lateralis (GL) was collected during the last minute of each running test. The root mean square (RMS) was normalized by maximal isometric voluntary contraction (MIVC) performed a priori in an isokinetic dynamometer. The RMS sum of all muscles (RMS LEG ) was considered as main neuromuscular economy parameter. PBMT with doses of 15, 30, and 60 J per site [33 diodes = 5 lasers (850 nm), 12 LEDs (670 nm), 8 LEDs (880 nm), and 8 LEDs (950 nm)] or placebo applications occurred before running tests. For the statistical analysis, the effect size was calculated. Moreover, a qualitative inference was used to determine the magnitude of differences between groups. Peak torque and RMS during MIVCs showed small effect sizes. According to magnitude-based inference, PBMT with dose of 15 J per site showed possibly and likely beneficial effects on neuromuscular economy during running at 8 and 9 km h -1 , respectively. On other hand, PBMT with doses of 30 and 60 J per site showed possible beneficial effects only during running at 9 km h -1 . We concluded that PBMT improve neuromuscular economy and the best PBMT dose was 15 J per site (total dose of 420 J).

  10. Lateral topography for reducing effective dose in low-dose chest CT.

    Science.gov (United States)

    Bang, Dong-Ho; Lim, Daekeon; Hwang, Wi-Sub; Park, Seong-Hoon; Jeong, Ok-man; Kang, Kyung Wook; Kang, Hohyung

    2013-06-01

    The purposes of this study were to assess radiation exposure during low-dose chest CT by using lateral topography and to compare the lateral topographic findings with findings obtained with anteroposterior topography alone and anteroposterior and lateral topography combined. From November 2011 to February 2012, 210 male subjects were enrolled in the study. Age, weight, and height of the men were recorded. All subjects were placed into one of three subgroups based on the type of topographic image obtained: anteroposterior topography, lateral topography, and both anteroposterior and lateral topography. Imaging was performed with a 128-MDCT scanner. CT, except for topography, was the same for all subjects. A radiologist analyzed each image, recorded scan length, checked for any insufficiencies in the FOV, and calculated the effective radiation dose. One-way analysis of variance and multiple comparisons were used to compare the effective radiation exposure and scan length between groups. The mean scan length in the anteroposterior topography group was significantly greater than that of the lateral topography group and the combined anteroposterior and lateral topography group (p topography group (0.735 ± 0.033 mSv) was significantly lower than that for the anteroposterior topography group (0.763 ± 0.038 mSv) and the combined anteroposterior and lateral topography group (0.773 ± 0.038) (p < 0.001). Lateral topographic low-dose CT was associated with a lower effective radiation dose and scan length than either anteroposterior topographic low-dose chest CT or low-dose chest CT with both anteroposterior and lateral topograms.

  11. Biological effects of low doses of radiation at low dose rate

    International Nuclear Information System (INIS)

    1996-05-01

    The purpose of this report was to examine available scientific data and models relevant to the hypothesis that induction of genetic changes and cancers by low doses of ionizing radiation at low dose rate is a stochastic process with no threshold or apparent threshold. Assessment of the effects of higher doses of radiation is based on a wealth of data from both humans and other organisms. 234 refs., 26 figs., 14 tabs

  12. Low doses effects and gamma radiations low dose rates; Les effets des faibles doses et des faibles debits de doses de rayons gamma

    Energy Technology Data Exchange (ETDEWEB)

    Averbeck, D [Institut Curie, CNRS UMR 2027, 75 - Paris (France)

    1999-07-01

    This expose wishes for bringing some definitions and base facts relative to the problematics of low doses effects and low dose rates effects. It shows some already used methods and some actual experimental approaches by focusing on the effects of ionizing radiations with a low linear energy transfer. (N.C.)

  13. Notes on the effect of dose uncertainty

    International Nuclear Information System (INIS)

    Morris, M.D.

    1987-01-01

    The apparent dose-response relationship between amount of exposure to acute radiation and level of mortality in humans is affected by uncertainties in the dose values. It is apparent that one of the greatest concerns regarding the human data from Hiroshima and Nagasaki is the unexpectedly shallow slope of the dose response curve. This may be partially explained by uncertainty in the dose estimates. Some potential effects of dose uncertainty on the apparent dose-response relationship are demonstrated

  14. Effective doses in diagnostic nuclear medicine in Brazil: Possibilities of optimisation

    International Nuclear Information System (INIS)

    Veslasques de Oliveira, S. M.; Tauhata, L.; Lipsztein, J. L.; Boasquevisque, E. M.

    2006-01-01

    With the aim of analysing protection of patient in diagnostic nuclear medicine, this study present data collected from sixteen nuclear medicine public and private institutions in three regions of the country, namely Northeast, Southeast and South regions 26,782 patients protocols were analysed, 24,371 adults and 2,411 children and teen-ages. Myocardial perfusion and bone imaging were responsible, respectively, for 53% and 23% of all diagnostic procedures. For 3.010 adults with age and weight registered, 96% had more than 40 years and mean weight was (69.9±14.1) kg for both genders. Due to similarities in physical characteristics between Brazilian adults patients and ICRP Reference Man, effective doses were estimated using ICRP conversion factors. For adults, the ratio mean activities per mean weigh was higher for female than male for the majority of procedures. For children and teen-ages, this ratio was higher for younger ages. Protocols should consider mean corporal weight for female and activities may be reduced accordingly. For children and teen-ages, effective doses may be reduced for younger ages. High absolved doses in bone surfaces of children due to 67Ga citrate imaging and bone scintigraphies should be investigated. (Author)

  15. Topics on study of low dose-effect relationship

    Energy Technology Data Exchange (ETDEWEB)

    Yamada, Takeshi [Toho Univ., School of Medicine, Tokyo (Japan); Ohyama, Harumi

    1999-09-01

    It is not exceptional but usually observed that a dose-effect relationship in biosystem is not linear. Sometimes, the low dose-effect relationship appears entirely contrary to the expectation from high dose-effect. This is called a 'hormesis' phenomena. A high dose irradiation inflicts certainly an injury on biosystem. No matter how low the dose may be, an irradiation might inflict some injury on biosystem according to Linear Non-Threshold hypothesis(LNT). On the contrary to the expectation, a low dose irradiation stimulates immune system, and promotes cell proliferation. This is called 'radiation hormesis'. The studies of the radiation hormesis are made on from four points of view as follows: (1) radiation adaptive response, (2) revitalization caused by a low dose stimulation, (3) a low dose response unexpected from the LNT hypothesis, (4) negation of the LNT hypothesis. The various empirical proofs of radiation hormesis are introduced in the report. (M . Suetake)

  16. Topics on study of low dose-effect relationship

    International Nuclear Information System (INIS)

    Yamada, Takeshi; Ohyama, Harumi

    1999-01-01

    It is not exceptional but usually observed that a dose-effect relationship in biosystem is not linear. Sometimes, the low dose-effect relationship appears entirely contrary to the expectation from high dose-effect. This is called a 'hormesis' phenomena. A high dose irradiation inflicts certainly an injury on biosystem. No matter how low the dose may be, an irradiation might inflict some injury on biosystem according to Linear Non-Threshold hypothesis(LNT). On the contrary to the expectation, a low dose irradiation stimulates immune system, and promotes cell proliferation. This is called 'radiation hormesis'. The studies of the radiation hormesis are made on from four points of view as follows: (1) radiation adaptive response, (2) revitalization caused by a low dose stimulation, (3) a low dose response unexpected from the LNT hypothesis, (4) negation of the LNT hypothesis. The various empirical proofs of radiation hormesis are introduced in the report. (M . Suetake)

  17. SU-F-P-19: Fetal Dose Estimate for a High-Dose Fluoroscopy Guided Intervention Using Modern Data Tools

    Energy Technology Data Exchange (ETDEWEB)

    Moirano, J [University of Washington, Seattle, WA (United States)

    2016-06-15

    Purpose: An accurate dose estimate is necessary for effective patient management after a fetal exposure. In the case of a high-dose exposure, it is critical to use all resources available in order to make the most accurate assessment of the fetal dose. This work will demonstrate a methodology for accurate fetal dose estimation using tools that have recently become available in many clinics, and show examples of best practices for collecting data and performing the fetal dose calculation. Methods: A fetal dose estimate calculation was performed using modern data collection tools to determine parameters for the calculation. The reference point air kerma as displayed by the fluoroscopic system was checked for accuracy. A cumulative dose incidence map and DICOM header mining were used to determine the displayed reference point air kerma. Corrections for attenuation caused by the patient table and pad were measured and applied in order to determine the peak skin dose. The position and depth of the fetus was determined by ultrasound imaging and consultation with a radiologist. The data collected was used to determine a normalized uterus dose from Monte Carlo simulation data. Fetal dose values from this process were compared to other accepted calculation methods. Results: An accurate high-dose fetal dose estimate was made. Comparison to accepted legacy methods were were within 35% of estimated values. Conclusion: Modern data collection and reporting methods ease the process for estimation of fetal dose from interventional fluoroscopy exposures. Many aspects of the calculation can now be quantified rather than estimated, which should allow for a more accurate estimation of fetal dose.

  18. Effects of a radiation dose reduction strategy for computed tomography in severely injured trauma patients in the emergency department: an observational study.

    Science.gov (United States)

    Kim, Soo Hyun; Jung, Seung Eun; Oh, Sang Hoon; Park, Kyu Nam; Youn, Chun Song

    2011-11-03

    Severely injured trauma patients are exposed to clinically significant radiation doses from computed tomography (CT) imaging in the emergency department. Moreover, this radiation exposure is associated with an increased risk of cancer. The purpose of this study was to determine some effects of a radiation dose reduction strategy for CT in severely injured trauma patients in the emergency department. We implemented the radiation dose reduction strategy in May 2009. A prospective observational study design was used to collect data from patients who met the inclusion criteria during this one year study (intervention group) from May 2009 to April 2010. The prospective data were compared with data collected retrospectively for one year prior to the implementation of the radiation dose reduction strategy (control group). By comparison of the cumulative effective dose and the number of CT examinations in the two groups, we evaluated effects of a radiation dose reduction strategy. All the patients met the institutional adult trauma team activation criteria. The radiation doses calculated by the CT scanner were converted to effective doses by multiplication by a conversion coefficient. A total of 118 patients were included in this study. Among them, 33 were admitted before May 2009 (control group), and 85 were admitted after May 2009 (intervention group). There were no significant differences between the two groups regarding baseline characteristics, such as injury severity and mortality. Additionally, there was no difference between the two groups in the mean number of total CT examinations per patient (4.8 vs. 4.5, respectively; p = 0.227). However, the mean effective dose of the total CT examinations per patient significantly decreased from 78.71 mSv to 29.50 mSv (p trauma patients effectively decreased the cumulative effective dose of the total CT examinations in the emergency department. But not effectively decreased the number of CT examinations.

  19. Multidetector CT radiation dose optimisation in adults: short- and long-term effects of a clinical audit

    Energy Technology Data Exchange (ETDEWEB)

    Tack, Denis [EpiCURA Hospital, Clinique Louis Caty, Department of Radiology, Baudour (Belgium); Jahnen, Andreas; Kohler, Sarah [CRP Henri Tudor, Luxembourg (Luxembourg); Harpes, Nico; Back, Carlo [Ministry of Health, Department of Radiation Protection, Luxembourg (Luxembourg); Maertelaer, Viviane de [Universite libre de Bruxelles, Institut de Recherche Interdisciplinaire en Biologie Humaine et Moleculaire and SBIM, Statistical Unit, Brussels (Belgium); Gevenois, Pierre Alain [Hopital Erasme, Department of Radiology, Brussels (Belgium)

    2014-01-15

    To report short- and long-term effects of an audit process intended to optimise the radiation dose from multidetector row computed tomography (MDCT). A survey of radiation dose from all eight MDCT departments in the state of Luxembourg performed in 2007 served as baseline, and involved the most frequently imaged regions (head, sinus, cervical spine, thorax, abdomen, and lumbar spine). CT dose index volume (CTDIvol), dose-length product per acquisition (DLP/acq), and DLP per examination (DLP/exa) were recorded, and their mean, median, 25th and 75th percentiles compared. In 2008, an audit conducted in each department helped to optimise doses. In 2009 and 2010, two further surveys evaluated the audit's impact on the dose delivered. Between 2007 and 2009, DLP/exa significantly decreased by 32-69 % for all regions (P < 0.001) except the lumbar spine (5 %, P = 0.455). Between 2009 and 2010, DLP/exa significantly decreased by 13-18 % for sinus, cervical and lumbar spine (P ranging from 0.016 to less than 0.001). Between 2007 and 2010, DLP/exa significantly decreased for all regions (18-75 %, P < 0.001). Collective dose decreased by 30 % and the 75th percentile (diagnostic reference level, DRL) by 20-78 %. The audit process resulted in long-lasting dose reduction, with DRLs reduced by 20-78 %, mean DLP/examination by 18-75 %, and collective dose by 30 %. (orig.)

  20. Radiobiological modelling of dose-gradient effects in low dose rate, high dose rate and pulsed brachytherapy

    International Nuclear Information System (INIS)

    Armpilia, C; Dale, R G; Sandilos, P; Vlachos, L

    2006-01-01

    This paper presents a generalization of a previously published methodology which quantified the radiobiological consequences of dose-gradient effects in brachytherapy applications. The methodology uses the linear-quadratic (LQ) formulation to identify an equivalent biologically effective dose (BED eq ) which, if applied uniformly to a specified tissue volume, would produce the same net cell survival as that achieved by a given non-uniform brachytherapy application. Multiplying factors (MFs), which enable the equivalent BED for an enclosed volume to be estimated from the BED calculated at the dose reference surface, have been calculated and tabulated for both spherical and cylindrical geometries. The main types of brachytherapy (high dose rate (HDR), low dose rate (LDR) and pulsed (PB)) have been examined for a range of radiobiological parameters/dimensions. Equivalent BEDs are consistently higher than the BEDs calculated at the reference surface by an amount which depends on the treatment prescription (magnitude of the prescribed dose) at the reference point. MFs are closely related to the numerical BED values, irrespective of how the original BED was attained (e.g., via HDR, LDR or PB). Thus, an average MF can be used for a given prescribed BED as it will be largely independent of the assumed radiobiological parameters (radiosensitivity and α/β) and standardized look-up tables may be applicable to all types of brachytherapy treatment. This analysis opens the way to more systematic approaches for correlating physical and biological effects in several types of brachytherapy and for the improved quantitative assessment and ranking of clinical treatments which involve a brachytherapy component

  1. Determination of attenuation factors for mortar of barite in terms of environmental dose equivalent and effective dose

    International Nuclear Information System (INIS)

    Almeida Junior, Airton T.; Campos, L.L.R.; Araujo, F.G.S.; Santos, M.A.P.; Nogueira, M.S.

    2014-01-01

    This work addresses the characterization of barite mortars used as Xray shielding materials through the following quantities: mass attenuation coefficient, air kerma, effective dose and ambient dose - H⁎(10). The experiment was carried out with the use of the following reference qualities: RQR4, RQR6, RQR9 e RQR10, specified in accordance with norm IEC 61267: Medical diagnostic Xray equipment - radiation conditions for use in the determination of characteristics. In this study values was determined experimentally for the attenuation of the Cream barite (density 2.99g/cm 3 , collected in the state of Sao Paulo), Purple barite (density 2.95g/cm 3 , collected in the state of Bahia) and White barite (density 3.10g/cm 3 , collected in the state of Paraiba). These materials, in the form of mortar, were disposed in the form of squares namely poof bodies, whose dimensions were 10 x 10 cm and thickness ranging from 3 to 15 mm approximately. In the experimental procedure, these proof bodies were irradiated with a Pantak, model HF320 industrial X-ray apparatus. The potentials applied to the respective X-ray tube were: 60kV, 80kV, 120kV and 150kV at a constant current of 1mA. The attenuation responses in function of thickness, for each of the materials analyzed, were used to draw the attenuation and transmission curves. The efficiency of the barite studied concerning the capacity to attenuate X-ray radiation for X-ray beams ranging from 60 to 150 kV indicated

  2. The monetary value of the collective dose equivalent unit (person-rem)

    International Nuclear Information System (INIS)

    Rodgers, Reginald C.

    1978-01-01

    In the design and operation of nuclear power reactor facilities, it is recommended that radiation exposures to the workers and the general public be kept as 'low as reasonably achievable' (ALARA). In the process of implementing this principle cost-benefit evaluations are part of the decision making process. For this reason a monetary value has to be assigned to the collective dose equivalent unit (person-rem). The various factors such as medical health care, societal penalty and manpower replacement/saving are essential ingredients to determine a monetary value for the person-rem. These factors and their dependence on the level of risk (or exposure level) are evaluated. Monetary values of well under $100 are determined for the public dose equivalent unit. The occupational worker person-rem value is determined to be in the range of $500 to about $5000 depending on the exposure level and the type of worker and his affiliation, i.e., temporary or permanent. A discussion of the variability and the range of the monetary values will be presented. (author)

  3. Reply to 'Comment on 'Collective dose: kill or cure?' '

    International Nuclear Information System (INIS)

    Dunster, H.J.

    2000-01-01

    Full text: In his letter, Mike Avison doubts my view that there is no threat of a serious build up of small doses from many (radiation) sources. His doubts arise from the analogy with other pollutants, notably carbon dioxide. But this is not a sound analogy. There are not many sources releasing long-lived radioactive substances to the environment. The principal examples are the nuclear fuel cycle and some metal mines. Neither source is likely to increase dramatically, certainly not rapidly. I have assumed the absence of atmospheric testing (and use) of nuclear weapons. The release of short-lived materials can produce only local problems. There are some groups exposed to more than one source, but the local controls are adequate and certainly do not call for the use of collective dose. Carbon dioxide is probably the worst possible analogue for radioactive materials. It is released extremely widely from a multitude of sources, including nearly 10 10 human beings. The releases seem likely to increase. I agree entirely with Mike Avison that this presents a serious problem, but it is no reason to invent a non-existent problem for radioactive materials. More generally, I am disturbed by the current trend to believe that environmental policies should be the same for all pollutants. This may be the 'politically correct' approach, but it is not scientific and may well prove to be seriously harmful to human communities. (author). Letter-to-the-editor

  4. Estimation of committed effective dose due to tritium in ground water in some places of Maharashtra

    International Nuclear Information System (INIS)

    Reddy, P.J.; Bhade, S.P.D.; Kolekar, R.V.; Singh, Rajvir; Pradeepkumar, K.S.

    2014-01-01

    In the present study Tritium concentration in well and bore well water samples were analyzed for the samples collected from the villages of Pune, Kolhapur and Ratnagiri. The activity concentration ranged from 0.55 - 3.66 Bq L -1 . The associated age-dependant dose from water ingestion in the study area was estimated. The effective committed dose recorded for different age classes is negligible compared to World Health Organization and U.S. Environmental Protection Agency dose guidelines. The Minimum Detectable Activity achieved was 1.5 Bq L -1 for a total counting time of 500 minutes. (author)

  5. Nuclear medicine at Camaguey, 1995-1999. Frequency of examinations and collective effective dose to the population; Medicina nuclear en Camaguey, 1995-1999. Frecuencia de examenes y dosis efectiva colectiva a la poblacion

    Energy Technology Data Exchange (ETDEWEB)

    Barreras, C. Aldo; Brigido, F. Osvaldo; Naranjo, L. Angela [Centro de Atencion a la Actividad Nuclear, Camaguey (Cuba)]. E-mail: sean@caonao.cmw.inf.cu; Lasserra, S. Oscar; Hernandez, G. Jose [Hospital Oncologico Maria Curie, Camaguey (Cuba)

    2001-07-01

    A study of the frequency of examinations for diagnosis in the territory of Camaguey-Ciego de Avila, Cuba, was made from the accumulated statistic in the period of 1995-1999 with the objective to obtain data to estimate the collective dose distributed to the population of this territory. It was determined that the annual frequency average of examinations was of 3,82 by each 1000 inhabitants. The obtained data allowed to evaluate the contribution of the different examinations from the collective dose, corresponding to the gamma radiographs of thyroid and pick up 43,73 and 43,36%, respectively, of the 54,43 Sv.man distributed to the population like annual. In this work the annual behavior of the collective dose for the studied period and its behavior in relation to the frequency of made examinations are analyzed. The smaller annual collective dose corresponded to 1996 with 39,05 Sv.man, while the greater value corresponded to 1999 with 66,67 Sv.man. The additional total damage for the studied period is considered: there would be 19,87 additional cases like result of 21073 nuclear medicine examinations, of which 13,6 correspond to mortal cancer. The obtained results are compared with the results reported for other countries.

  6. Considering job-related doses in Europe

    International Nuclear Information System (INIS)

    Anon.

    1990-01-01

    As part of its role of safeguarding nuclear workers the Commission of the European Community has created a European data bank on job-related doses. The data bank is intended to correlate jobs and workers doses and is a useful instrument to observe the collected doses of workers in nuclear power plants. Set up in 1980, the database covers doses in PWRs and BWRs. To create it a questionnaire is distributed to plant operators. The database responses provide information on (i) Trends in total collective doses, including those for some ancillary jobs. It is possible to see trends by calendar year and by fuel cycle number. (ii) Other trends such as dose in terms of installed power or dose in terms of power station design. (iii) Dose differences between power stations, normalized against the differences in dose rates. This is only possible for PWRs that monitor dose rates using the EPRI standard monitoring programme. (vi) The relative dose rate in each plant for a defined job. The questionnaire is not perfectly adapted to all the working criteria in nuclear power stations but it is an effective tool for implementing radiation protection. (author)

  7. Health effects of daily airborne particle dose in children: Direct association between personal dose and respiratory health effects

    International Nuclear Information System (INIS)

    Buonanno, Giorgio; Marks, Guy B.; Morawska, Lidia

    2013-01-01

    Air pollution is a widespread health problem associated with respiratory symptoms. Continuous exposure monitoring was performed to estimate alveolar and tracheobronchial dose, measured as deposited surface area, for 103 children and to evaluate the long-term effects of exposure to airborne particles through spirometry, skin prick tests and measurement of exhaled nitric oxide (eNO). The mean daily alveolar deposited surface area dose received by children was 1.35 × 10 3 mm 2 . The lowest and highest particle number concentrations were found during sleeping and eating time. A significant negative association was found between changes in pulmonary function tests and individual dose estimates. Significant differences were found for asthmatics, children with allergic rhinitis and sensitive to allergens compared to healthy subjects for eNO. Variation is a child's activity over time appeared to have a strong impact on respiratory outcomes, which indicates that personal monitoring is vital for assessing the expected health effects of exposure to particles. -- Highlights: •Particle dose was estimated through personal monitoring on more than 100 children. •We focused on real-time daily dose of particle alveolar deposited surface area. •Spirometry, skin prick and exhaled Nitric Oxide tests were performed. •Negative link was found between changes in pulmonary functions and individual doses. •A child's lifestyle appeared to have a strong impact on health respiratory outcomes. -- The respiratory health effects of daily airborne particle dose on children through personal monitoring

  8. Dose-effective investigation of intraarterial r-Sak in canine model with acute cerebral infarctions

    International Nuclear Information System (INIS)

    Liu Sheng; Shi Haibin; Zhang Peng; Wang Chenghu; Zhou Chunguo; Li Linsun

    2007-01-01

    Objective: To compare the effect and complications of intraarterial thrombolysis with different doses of recombinant-staphylokinase (r-Sak) in canine model with acute cerebral infarction, and then to find out the most properly appropriate effective dose. Methods: The model with left cerebral embolism was established with interventional technique in 24 beagle adult dogs. They were randomly divided into 4 groups including control group(saline, 10 ml), group of low dose(r-Sak, 5 000 u/kg), middle dose(r-Sak, 10 000 u/kg) and high dose(r-Sak, 20 000 u/kg). Angiography and intraarterial thrombolysis were performed within 30 minutes after the embolization. Microcatheter was superselectively inserted into left carotid artery. Five hour's later with a repeated angiography at half, 1 and 2 hours after thrombolysis to observe the recanalization. Blood samples were collected at a series of time pre-and post-thrombolysis to test the plasma levels of PT, APTT and D-dimer. These canines were sacrificed, and their cerebri were taken out for pathologic study by the end of 24 hours. Results: The rates of efficacy within 2 hours after thrombolysis were 10.0% (1/10) in control group, 40.0% (4/10) in low dose group, 90.9% (10/11) in middle dose group and 100% (9/9) in high dose group. The rates of complete recanalization were 0, 10% (1/10), 36.4% (4/11) and 66.7% (6/9), correspondingly and respectively. There were statistically obvious differences between the 3 groups (P 0.05). Death occurred in 1 canine(high dose group) within 24 hours after thrombolysis with hemorrhagic lesion in parietal lobe of brain. No other severe complications ocurred. Conclusions: (1) Intraarterial thrombolysis with r-Sak within 5 hours after onset of thrombosis is effective and feasible. Intraarterial r-Sak shows strong thrombolytic effect for white thrombus including a few platelets. There is relative high rate of recanalization with no less than 10 000U/kg of r-Sak but accompanied with high risk of

  9. Radiation doses to personnel in clinics for gynecologic oncology

    International Nuclear Information System (INIS)

    Forsberg, B.; Spanne, P.

    1985-01-01

    Radium or Cesium is used for radiotherapy of gynecologic cancer at six clinics in Sweden. This report gives a survey of the radiation doses the personnel is exposed to. The measurement were performed using TL-dosimeters. The dose equivalents for different parts of the body at specific working moments was deduced as well as the effective dose equivalent and the collective dose equivalent. 1983 the total collective dose equivalent for the six clinics was 1.3 manSv, which corresponds to 3.9 manmSv/g equivalent mass of Radium used at the treatments. (With 11 tables and 10 figures) (L.E.)

  10. Significance and principles of the calculation of the effective dose equivalent for radiological protection of personnel and patients

    International Nuclear Information System (INIS)

    Drexler, G.; Williams, G.

    1985-01-01

    The application of the effective dose equivalent, Hsub(E), concept for radiological protection assessments of occupationally exposed persons is justifiable by the practicability thus achieved with regard to the limiting principles. Nevertheless, it would be proper logic to further use as the basic limiting quantity the real physical dose equivalent of homogeneous whole-body exposure, and for inhomogeneous whole-body irradiation the Hsub(E) value, calculated by means of the concept of the effective dose equivalent. For then the required concepts, models and calculations would not be connected with a basic radiation protection quantity. Application of the effective dose equivalent for radiation protection assessments for patients is misleading and is not practical with regard to assessing an individual or collective radiation risk of patients. The quantity of expected harm would be better suited to this purpose. There is no need to express the radiation risk by a dose quantity, which means careless handling of good information. (orig./WU) [de

  11. Dose rate effect on low-dose hyper-radiosensitivity with cells in vitro

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Geon-Min; Kim, Eun-Hee [Seoul National University, Seoul (Korea, Republic of)

    2016-10-15

    Low-dose hyper-radiosensitivity (HRS) is the phenomenon that mammalian cells exhibit higher sensitivity to radiation at low doses (< 0.5 Gy) than expected by the linear-quadratic model. At doses above 0.5Gy, the cellular response is recovered to the level expected by the linear-quadratic model. This transition is called the increased radio-resistance (IRR). HRS was first verified using Chinese hamster V79 cells in vitro by Marples and has been confirmed in studies with other cell lines including human normal and tumor cells. HRS is known to be induced by inactivation of ataxia telangiectasia-mutated (ATM), which plays a key role in repairing DNA damages. Considering the connection between ATM and HRS, one can infer that dose rate may affect cellular response regarding HRS at low doses. In this study, we quantitated the effect of dose rate on HRS by clonogenic assay with normal and tumor cells. The HRS of cells at low dose exposures is a phenomenon already known. In this study, we observed HRS of rat normal diencephalon cells and rat gliosarcoma cells at doses below 1 Gy. In addition, we found that dose rate mattered. HRS occurred at low doses, but only when total dose was delivered at a rate below certain level.

  12. Estimating the population dose from nuclear medicine examinations towards establishing diagnostic reference levels

    International Nuclear Information System (INIS)

    Niksirat, Fatemeh; Monfared, Ali Shabestani; Deevband, Mohammad Reza; Amiri, Mehrangiz; Gholami, Amir

    2016-01-01

    This study conducted a review on nuclear medicine (NM) services in Mazandaran Province with a view to establish adult diagnostic reference levels (DRLs) and provide updated data on population radiation exposure resulting from diagnostic NM procedures. The data were collected from all centers in all cities of Mazandaran Province in the North of Iran from March 2014 to February 2015. The 75 th percentile of the distribution and the average administered activity (AAA) were calculated and the average effective dose per examination, collective effective dose to the population and annual effective dose per capita were estimated using dose conversion factors. The gathered data were analyzed via SPSS (version 18) software using descriptive statistics. Based on the data of this study, the collective effective dose was 95.628 manSv, leading to a mean effective dose of 0.03 mSv per capita. It was also observed that the myocardial perfusion was the most common procedure (50%). The 75 th percentile of the distribution of administered activity (AA) represents the DRL. The AAA and the 75 th percentile of the distribution of AA are slightly higher than DRL of most European countries. Myocardial perfusion is responsible for most of the collective effective dose and it is better to establish national DRLs for myocardial perfusion and review some DRL values through the participation of NM specialists in the future

  13. A graphical review of radiogenic animal cancer data using the 'dose and dose-rate map'

    International Nuclear Information System (INIS)

    Yoshida, Kazuo; Hoshi, Yuko; Sakai, Kazuo

    2008-01-01

    We have been investigating the effects of low dose or low dose rate irradiation on mice, using our low dose-rate irradiation facilities. In these studies, we found that the effects were highly dependent on both total dose and dose rate. To show this visually, we proposed the 'dose/dose rate map', and plotted the results of our laboratory and our co-workers. The map demonstrated that dose/dose rate plane could be divided into three areas; 1) An area where harmful effects are observed, 2) An area where no harmful effects are observed, and 3) Another area, between previous two areas, where certain protective functions are enhanced. As this map would be a powerful tool to find some trend among the vast numbers of data relating the biological effects of ionizing radiation, we have developed a computer program which plots the collected data on the dose/dose rate map sorting by experimental conditions. In this study, we graphically reviewed and analyzed the data relating to the lifespan studies of animals with a view to determining the relationships between doses and dose rates of ionizing radiation and cancer incidence. The data contains about 800 sets of experiments, which concerns 187,000 animals exposed to gamma ray or X-ray and their 112,000 controls, and total of about 30,000 cancers in exposed animals and 14,000 cancers in controls. About 800 points of data were plotted on the dose/dose rate map. The plot showed that 1) The divided three areas in the dose/dose rate map were generally confirmed by these 800 points of data, and 2) In some particular conditions, e.g. sarcoma by X-rays, the biologically effective area is extended to relatively high dose/dose rate area. (author)

  14. Cancer risk of low dose/low dose rate radiation: a meta-analysis of cancer data of mammals exposed to low doses of radiation

    International Nuclear Information System (INIS)

    Ogata, Hiromitsu; Magae, Junji

    2008-01-01

    Full text: Linear No Threshold (LNT) model is a basic theory for radioprotection, but the adaptability of this hypothesis to biological responses at low doses or at low dose rates is not sufficiently investigated. Simultaneous consideration of the cumulative dose and the dose rate is necessary for evaluating the risk of long-term exposure to ionizing radiation at low dose. This study intends to examine several numerical relationships between doses and dose rates in biological responses to gamma radiation. Collected datasets on the relationship between dose and the incidence of cancer in mammals exposed to low doses of radiation were analysed using meta-regression models and modified exponential (MOE) model, which we previously published, that predicts irradiation time-dependent biological response at low dose rate ionizing radiation. Minimum doses of observable risk and effective doses with a variety of dose rates were calculated using parameters estimated by fitting meta-regression models to the data and compared them with other statistical models that find values corresponding to 'threshold limits'. By fitting a weighted regression model (fixed-effects meta-regression model) to the data on risk of all cancers, it was found that the log relative risk [log(RR)] increased as the total exposure dose increased. The intersection of this regression line with the x-axis denotes the minimum dose of observable risk. These estimated minimum doses and effective doses increased with decrease of dose rate. The goodness of fits of MOE-model depended on cancer types, but the total cancer risk is reduced when dose rates are very low. The results suggest that dose response curve for cancer risk is remarkably affected by dose rate and that dose rate effect changes as a function of dose rate. For scientific discussion on the low dose exposure risk and its uncertainty, the term 'threshold' should be statistically defined, and dose rate effects should be included in the risk

  15. Analysis of the evolution of the collective dose in nuclear power plants in Spain

    International Nuclear Information System (INIS)

    Ponjuan Reyes, G.; Ruibia Rodiz, M. A. de la; Rosales Calvo, M.; Labarta Mancho, T.; Calavia Gimenez, I.

    2011-01-01

    This article presents an analysis of the evolution of occupational collective dose of the Spanish nuclear power planLs during the period 2000 - 2008 within the international context, by the Nuclear SafeLy Council (CSN) in order to have information contrasted to assessing the extent of applicaLion of the ALARA criLeria in the Spanish plants and identify areas of priority attention.

  16. Radiation effects in wild terrestrial vertebrates - the EPIC collection.

    Science.gov (United States)

    Sazykina, Tatiana; Kryshev, Ivan I

    2006-01-01

    The paper presents data on radiation effects in populations of wild vertebrate animals inhabiting contaminated terrestrial ecosystems. The data were extracted from the database "Radiation effects on biota", compiled within the framework of the EC Project EPIC (2000-2003). The data collection, based on publications in Russian, demonstrates radiation effects in the areas characterized with high levels of radionuclides (Kyshtym radioactive trace; "spots" of enhanced natural radioactivity in the Komi region of Russia; territories contaminated from the Chernobyl fallout). The data covers a wide range of exposures from acute accidental irradiation to lifetime exposures at relatively low dose rates. Radiation effects include mortality, changes in reproduction, decrease of health, ecological effects, cytogenetic effects, adaptation to radiation, and others. Peculiarities of radiation effects caused by different radionuclides are described, also the severity of effects as they appear in different organisms (e.g. mice, frogs, birds, etc.).

  17. Radiation effects in wild terrestrial vertebrates - the EPIC collection

    International Nuclear Information System (INIS)

    Sazykina, Tatiana; Kryshev, Ivan I.

    2006-01-01

    The paper presents data on radiation effects in populations of wild vertebrate animals inhabiting contaminated terrestrial ecosystems. The data were extracted from the database 'Radiation effects on biota', compiled within the framework of the EC Project EPIC (2000-2003). The data collection, based on publications in Russian, demonstrates radiation effects in the areas characterized with high levels of radionuclides (Kyshtym radioactive trace; 'spots' of enhanced natural radioactivity in the Komi region of Russia; territories contaminated from the Chernobyl fallout). The data covers a wide range of exposures from acute accidental irradiation to lifetime exposures at relatively low dose rates. Radiation effects include mortality, changes in reproduction, decrease of health, ecological effects, cytogenetic effects, adaptation to radiation, and others. Peculiarities of radiation effects caused by different radionuclides are described, also the severity of effects as they appear in different organisms (e.g. mice, frogs, birds, etc.)

  18. Effects of a radiation dose reduction strategy for computed tomography in severely injured trauma patients in the emergency department: an observational study

    Directory of Open Access Journals (Sweden)

    Kim Soo Hyun

    2011-11-01

    Full Text Available Abstract Background Severely injured trauma patients are exposed to clinically significant radiation doses from computed tomography (CT imaging in the emergency department. Moreover, this radiation exposure is associated with an increased risk of cancer. The purpose of this study was to determine some effects of a radiation dose reduction strategy for CT in severely injured trauma patients in the emergency department. Methods We implemented the radiation dose reduction strategy in May 2009. A prospective observational study design was used to collect data from patients who met the inclusion criteria during this one year study (intervention group from May 2009 to April 2010. The prospective data were compared with data collected retrospectively for one year prior to the implementation of the radiation dose reduction strategy (control group. By comparison of the cumulative effective dose and the number of CT examinations in the two groups, we evaluated effects of a radiation dose reduction strategy. All the patients met the institutional adult trauma team activation criteria. The radiation doses calculated by the CT scanner were converted to effective doses by multiplication by a conversion coefficient. Results A total of 118 patients were included in this study. Among them, 33 were admitted before May 2009 (control group, and 85 were admitted after May 2009 (intervention group. There were no significant differences between the two groups regarding baseline characteristics, such as injury severity and mortality. Additionally, there was no difference between the two groups in the mean number of total CT examinations per patient (4.8 vs. 4.5, respectively; p = 0.227. However, the mean effective dose of the total CT examinations per patient significantly decreased from 78.71 mSv to 29.50 mSv (p Conclusions The radiation dose reduction strategy for CT in severely injured trauma patients effectively decreased the cumulative effective dose of the total

  19. Comparison of two dose and three dose human papillomavirus vaccine schedules: cost effectiveness analysis based on transmission model.

    Science.gov (United States)

    Jit, Mark; Brisson, Marc; Laprise, Jean-François; Choi, Yoon Hong

    2015-01-06

    To investigate the incremental cost effectiveness of two dose human papillomavirus vaccination and of additionally giving a third dose. Cost effectiveness study based on a transmission dynamic model of human papillomavirus vaccination. Two dose schedules for bivalent or quadrivalent human papillomavirus vaccines were assumed to provide 10, 20, or 30 years' vaccine type protection and cross protection or lifelong vaccine type protection without cross protection. Three dose schedules were assumed to give lifelong vaccine type and cross protection. United Kingdom. Males and females aged 12-74 years. No, two, or three doses of human papillomavirus vaccine given routinely to 12 year old girls, with an initial catch-up campaign to 18 years. Costs (from the healthcare provider's perspective), health related utilities, and incremental cost effectiveness ratios. Giving at least two doses of vaccine seems to be highly cost effective across the entire range of scenarios considered at the quadrivalent vaccine list price of £86.50 (€109.23; $136.00) per dose. If two doses give only 10 years' protection but adding a third dose extends this to lifetime protection, then the third dose also seems to be cost effective at £86.50 per dose (median incremental cost effectiveness ratio £17,000, interquartile range £11,700-£25,800). If two doses protect for more than 20 years, then the third dose will have to be priced substantially lower (median threshold price £31, interquartile range £28-£35) to be cost effective. Results are similar for a bivalent vaccine priced at £80.50 per dose and when the same scenarios are explored by parameterising a Canadian model (HPV-ADVISE) with economic data from the United Kingdom. Two dose human papillomavirus vaccine schedules are likely to be the most cost effective option provided protection lasts for at least 20 years. As the precise duration of two dose schedules may not be known for decades, cohorts given two doses should be closely

  20. Low dose radiation enhance the anti-tumor effect of high dose radiation on human glioma cell U251

    International Nuclear Information System (INIS)

    Wang Chang; Wang Guanjun; Tan Yehui; Jiang Hongyu; Li Wei

    2008-01-01

    Objective: To detect the effect on the growth of human glioma cell U251 induced by low dose irradiation and low dose irradiation combined with large dose irradiation. Methods: Human glioma cell line U251 and nude mice carried with human glioma were used. The tumor cells and the mice were treated with low dose, high dose, and low dose combined high dose radiation. Cells growth curve, MTT and flow cytometry were used to detect the proliferation, cell cycle and apoptosis of the cells; and the tumor inhibition rate was used to assess the growth of tumor in vivo. Results: After low dose irradiation, there was no difference between experimental group and control group in cell count, MTT and flow cytometry. Single high dose group and low dose combined high dose group both show significantly the suppressing effect on tumor cells, the apoptosis increased and there was cell cycle blocked in G 2 period, but there was no difference between two groups. In vivo apparent anti-tumor effect in high dose radiation group and the combining group was observed, and that was more significant in the combining group; the prior low dose radiation alleviated the injury of hematological system. There was no difference between single low dose radiation group and control. Conclusions: There is no significant effect on human glioma cell induced by low dose radiation, and low dose radiation could not induce adaptive response. But in vivo experience, low dose radiation could enhance the anti-tumor effect of high dose radiation and alleviated the injury of hematological system. (authors)

  1. A PC program for estimating organ dose and effective dose values in computed tomography

    International Nuclear Information System (INIS)

    Kalender, W.A.; Schmidt, B.; Schmidt, M.; Zankl, M.

    1999-01-01

    Dose values in CT are specified by the manufacturers for all CT systems and operating conditions in phantoms. It is not trivial, however, to derive dose values in patients from this information. Therefore, we have developed a PC-based program which calculates organ dose and effective dose values for arbitrary scan parameters and anatomical ranges. Values for primary radiation are derived from measurements or manufacturer specifications; values for scattered radiation are derived from Monte Carlo calculations tabulated for standard anthropomorphic phantoms. Based on these values, organ doses can be computed by the program for arbitrary scan protocols in conventional and in spiral CT. Effective dose values are also provided, both with ICRP 26 and ICRP 60 tissue-weighting coefficients. Results for several standard CT protocols are presented in tabular form in this paper. In addition, potential for dose reduction is demonstrated, for example, in spiral CT and in quantitative CT. Providing realistic patient dose estimates for arbitrary CT protocols is relevant both for the physician and the patient, and it is particularly useful for educational and training purposes. The program, called WinDose, is now in use at the Erlangen University hospitals (Germany) as an information tool for radiologists and patients. Further extensions are planned. (orig.)

  2. Absorbed dose thresholds and absorbed dose rate limitations for studies of electron radiation effects on polyetherimides

    Science.gov (United States)

    Long, Edward R., Jr.; Long, Sheila Ann T.; Gray, Stephanie L.; Collins, William D.

    1989-01-01

    The threshold values of total absorbed dose for causing changes in tensile properties of a polyetherimide film and the limitations of the absorbed dose rate for accelerated-exposure evaluation of the effects of electron radiation in geosynchronous orbit were studied. Total absorbed doses from 1 kGy to 100 MGy and absorbed dose rates from 0.01 MGy/hr to 100 MGy/hr were investigated, where 1 Gy equals 100 rads. Total doses less than 2.5 MGy did not significantly change the tensile properties of the film whereas doses higher than 2.5 MGy significantly reduced elongation-to-failure. There was no measurable effect of the dose rate on the tensile properties for accelerated electron exposures.

  3. The linear non threshold conception 'Dose-effect' as a base for standardization of human exposure to ionizing radiation. Arguments pro and con

    International Nuclear Information System (INIS)

    Vassilev, G.

    2000-01-01

    Examples and argument are presented for reconsidering of the application of the threshold conception in low dose risk assessment. Some of the reasons mentioned are: inapplicability of the quantity 'collective dose' for low doses; serious reassessment of risk coefficients for radiation mutagenesis; report on increasing data on the so called hormesis - stimulation and potential effects from exposure of test animals nas humans to low doses of ionizing radiation

  4. Towards a new dose and dose-rate effectiveness factor (DDREF)? Some comments.

    Science.gov (United States)

    Chadwick, K H

    2017-06-26

    The aim of this article is to offer a broader, mechanism-based, analytical tool than that used by (Rühm et al 2016 Ann. ICRP 45 262-79) for the interpretation of cancer induction relationships. The article explains the limitations of this broader analytical tool and the implications of its use in view of the publications by Leuraud et al 2015 (Lancet Haematol. 2 e276-81) and Richardson et al 2015 (Br. Med. J. 351 h5359). The publication by Rühm et al 2016 (Ann. ICRP 45 262-79), which is clearly work in progress, reviews the current status of the dose and dose-rate effectiveness factor (DDREF) as recommended by the ICRP. It also considers the issues which might influence a reassessment of both the value of the DDREF as well as its application in radiological protection. In this article, the problem is approached from a different perspective and starts by commenting on the limited scientific data used by Rühm et al 2016 (Ann. ICRP 45 262-79) to develop their analysis which ultimately leads them to use a linear-quadratic dose effect relationship to fit solid cancer mortality data from the Japanese life span study of atomic bomb survivors. The approach taken here includes more data on the induction of DNA double strand breaks and, using experimental data taken from the literature, directly relates the breaks to cell killing, chromosomal aberrations and somatic mutations. The relationships are expanded to describe the induction of cancer as arising from radiation induced cytological damage coupled to cell killing since the cancer mutated cell has to survive to express its malignant nature. Equations are derived for the induction of cancer after both acute and chronic exposure to sparsely ionising radiation. The equations are fitted to the induction of cancer in mice to illustrate a dose effect relationship over the total dose range. The 'DDREF' derived from the two equations varies with dose and the DDREF concept is called into question. Although the equation for

  5. Patient and population doses of x-ray diagnostics in Finland

    Energy Technology Data Exchange (ETDEWEB)

    Rannikko, S; Karila, K T.K.; Toivonen, M

    1997-09-01

    Periodic surveys of patient and population doses are important because of the large contribution of x-ray diagnostics to the artificial population dose. Measured entrance surface doses and dose-area products are the main quantities used for monitoring patient doses in hospitals, and most population dose studies have been derived from these quantities and from the frequences of x-ray examinations. This study is based on the radiation, exposure geometry, and patient parameters recorded by experienced radiographers and postgraduated students. The software used in the work (ODS-60 of Rados Technology) suits the determination of effective and organ doses from such detailed data using a human-like patient phantom which can be adapted for sex and size. The program, together with the very detailed input data, made it possible to determine organ equivalent and effective doses for complicated dynamic x-ray examinations and interventions in more detail than in previous studies. Collective organ and effective doses were derived for 50 examination types. The annual collective dose from diagnostic x-ray examinations in 1994 was 0.5 mSv per capita in Finland. The five groups of examinations or examinations that had greatest contributions to the collective dose were CT, barium enema: double contrast, lumbar spine, carotid angiography, and intestinal transit. Together they represented for about 60 % of the total dose. The highest dose-area products (about 2000 Gy cm{sup 2}) were obtained from certain angiographic and interventional examinations. A literature survey showed that Finland patient doses are at the same average level as in other countries of a high standard of health care. (orig.). 125 refs.

  6. Patient and population doses of x-ray diagnostics in Finland

    International Nuclear Information System (INIS)

    Rannikko, S.; Karila, K.T.K.; Toivonen, M.

    1997-09-01

    Periodic surveys of patient and population doses are important because of the large contribution of x-ray diagnostics to the artificial population dose. Measured entrance surface doses and dose-area products are the main quantities used for monitoring patient doses in hospitals, and most population dose studies have been derived from these quantities and from the frequences of x-ray examinations. This study is based on the radiation, exposure geometry, and patient parameters recorded by experienced radiographers and postgraduated students. The software used in the work (ODS-60 of Rados Technology) suits the determination of effective and organ doses from such detailed data using a human-like patient phantom which can be adapted for sex and size. The program, together with the very detailed input data, made it possible to determine organ equivalent and effective doses for complicated dynamic x-ray examinations and interventions in more detail than in previous studies. Collective organ and effective doses were derived for 50 examination types. The annual collective dose from diagnostic x-ray examinations in 1994 was 0.5 mSv per capita in Finland. The five groups of examinations or examinations that had greatest contributions to the collective dose were CT, barium enema: double contrast, lumbar spine, carotid angiography, and intestinal transit. Together they represented for about 60 % of the total dose. The highest dose-area products (about 2000 Gy cm 2 ) were obtained from certain angiographic and interventional examinations. A literature survey showed that Finland patient doses are at the same average level as in other countries of a high standard of health care. (orig.)

  7. Biological effective dose studies in carcinoma of uterine cervix

    International Nuclear Information System (INIS)

    Yadav, Poonam; Ramasubramanian, V.

    2008-01-01

    Cancer of cervix is the second most common cancer worldwide among women. Several treatments related protocols of radiotherapy have been followed over few decades in its treatment for evaluating the response. These physical doses varying on the basics of fractionation size, dose rate and total dose needed to be indicated as biological effective dose (BED) to rationalize these treatments. The curative potential of radiation therapy in the management of carcinoma of the cervix is greatly enhanced by the use of intracavitary brachytherapy. Successful brachytherapy requires the high radiation dose to be delivered to the tumor where as minimum radiation dose reach to surrounding normal tissue. Present study is aimed to evaluate biologically effective dose in patients receiving high dose-rate brachytherapy plus external beam radiotherapy based on tumor cell proliferation values in cancer of the cervix patients. The study includes 30 patients' data as a retrospective analysis. In addition determine extent of a dose-response relationship existing between the biological effective dose at Point A and the bladder and rectum and the clinical outcomes

  8. Collection and use of individual behavioral and consumption rate data to improve reconstruction of thyroid doses from nuclear weapons tests in Kazakhstan

    International Nuclear Information System (INIS)

    Drozdovitch, Vladimir; Schonfeld, Sara; Bouville, Andre; Land, Charles; Luckyanov, Nick; Simon, Steven L.; Schwerin, Michael

    2008-01-01

    Full text: Historical behavioral and consumption rate data were collected from residents of Kazakhstan exposed to nuclear weapons testing fallout using a focus group data collection strategy. These data will enable improved thyroid dose estimation in a radiation epidemiological study being carried out the U.S. National Cancer Institute. The study on the relationship of radiation exposure from weapons testing fallout and thyroid disease in a cohort of 2,994 subjects is now in a stage of improving earlier dose estimates based on individual information collected from a basic questionnaire administered to the study population in 1998. The study subjects of both Kazakh and Russian origin were exposed during childhood to radioactive fallout from nuclear weapons tests conducted at the Semipalatinsk Nuclear Test Site between 1949 and 1962. Due to the long time since exposure, a well developed strategy is necessary to encourage accurate memory recall. Limitations of the data collected in 1998 suggested the need to obtain reliable information that is tailored specific to the requirements of the dose reconstruction algorithm and to the evaluation of individual dose uncertainties. Focus group data collection in Kazakhstan in 2007 involved four 8-person focus groups (three of women and one of men) in each of four exposed settlements where thyroid disease screening was conducted in 1998. Age-specific data on relevant childhood behaviour, including time spent indoors and consumption of milk and other dairy products from cows, goats, horses, and sheep, were collected from women's groups. Men's focus groups were interviewed about construction materials of houses and schools as well as animal grazing patterns and supplemental feed to animals. Information obtained from the focus groups are being used to derive the settlement-, ethnicity-, age-, and gender-specific (where appropriate) probability density distributions on individual consumption rates of milk and dairy products

  9. Biological effects of low-dose ionizing radiation exposure

    International Nuclear Information System (INIS)

    Reinoehl-Kompa, Sabine; Baldauf, Daniela; Heller, Horst

    2009-01-01

    The report on the meeting of the Strahlenschutzkommission 2007 concerning biological effects of low-dose ionizing radiation exposure includes the following contributions: Adaptive response. The importance of DNA damage mechanisms for the biological efficiency of low-energy photons. Radiation effects in mammography: the relative biological radiation effects of low-energy photons. Radiation-induced cataracts. Carcinomas following prenatal radiation exposure. Intercellular apoptosis induction and low-dose irradiation: possible consequences for the oncogenesis control. Mechanistic models for the carcinogenesis with radiation-induced cell inactivation: application to all solid tumors in the Japanese atomic bomb survivors. Microarrays at low radiation doses. Mouse models for the analysis of biological effects of low-dose ionizing radiation. The bystander effect: observations, mechanisms and implications. Lung carcinoma risk of Majak workers - modeling of carcinogenesis and the bystander effect. Microbeam studies in radiation biology - an overview. Carcinogenesis models with radiation-induced genomic instability. Application to two epidemiological cohorts.

  10. Determination of effective dose of antimalarial from Cassia ...

    African Journals Online (AJOL)

    However, further investigation is required to determine an effective dose of the administered extract for a higher inhibitory effect and increasing effectiveness of the extract. Material and Methods: To determine the effective dose of ethanol extract of C. spectabilis leaves, a "4-day suppressive test"of Peter was performed with ...

  11. Dose-rate effects in external beam radiotherapy redux

    International Nuclear Information System (INIS)

    Ling, C. Clifton; Gerweck, Leo E.; Zaider, Marco; Yorke, Ellen

    2010-01-01

    Recent developments in external beam radiotherapy, both in technical advances and in clinical approaches, have prompted renewed discussions on the potential influence of dose-rate on radio-response in certain treatment scenarios. We consider the multiple factors that influence the dose-rate effect, e.g. radical recombination, the kinetics of sublethal damage repair for tumors and normal tissues, the difference in α/β ratio for early and late reacting tissues, and perform a comprehensive literature review. Based on radiobiological considerations and the linear-quadratic (LQ) model we estimate the influence of overall treatment time on radio-response for specific clinical situations. As the influence of dose-rate applies to both the tumor and normal tissues, in oligo-fractionated treatment using large doses per fraction, the influence of delivery prolongation is likely important, with late reacting normal tissues being generally more sensitive to the dose-rate effect than tumors and early reacting tissues. In conventional fractionated treatment using 1.8-2 Gy per fraction and treatment times of 2-10 min, the influence of dose-rate is relatively small. Lastly, the dose-rate effect in external beam radiotherapy is governed by the overall beam-on-time, not by the average linac dose-rate, nor by the instantaneous dose-rate within individual linac pulses which could be as high as 3 x 10 6 MU/min.

  12. Effective dose and cancer risk in PET/CT exams

    International Nuclear Information System (INIS)

    Pinto, Gabriella M.; Sa, Lidia Vasconcellos de

    2013-01-01

    Due to the use of radiopharmaceutical positron-emitting in PET exam and realization of tomography by x-ray transmission in CT examination, an increase of dose with hybrid PET/CT technology is expected. However, differences of doses have been reported in many countries for the same type of procedure. It is expected that the dose is an influent parameter to standardize the protocols of PET/CT. This study aimed to estimate the effective doses and absorbed in 65 patients submitted to oncological Protocol in a nuclear medicine clinic in Rio de Janeiro, considering the risk of induction of cancer from the scan. The CT exam-related doses were estimated with a simulator of PMMA and simulated on the lmPACT resistance, which for program effective dose, were considered the weight factors of the lCRP 103. The PET exam doses were estimated by multiplying the activity administered to the patient with the ICRP dose 80 factors. The radiological risk for cancer incidence were estimated according to the ICRP 103. The results showed that the effective dose from CT exam is responsible for 70% of the effective total in a PET/CT scan. values of effective dose for the PET/CT exam reached average values of up to 25 mSv leading to a risk of 2, 57 x 10 -4 . Considering that in staging of oncological diseases at least four tests are performed annually, the total risk comes to 1,03x 10 -3

  13. Effective dose for patient in multimode panoramic radiography

    International Nuclear Information System (INIS)

    Yasaki, Shiro; Daibo, Motoji

    1999-01-01

    In recent years, multimode panoramic radiography has had various functions, such as the auto exposure function, auto focus function (auto function), TMJ radiography and tomogram radiography functions. The purpose of this study was to estimate the effective dose for patients in each mode of the new multimode panoramic radiography (J. MORITA MFG. CORP. Dental Panorama X-ray Apparatus: Veraview Scope X 600). The absorbed doses in important organs involved in the causation of stochastic effects were measured by a thermoluminescent dosimeter using RANDO phantom. The effective doses were calculated using modified tissue weighting factors recommended by the International Commission on Radiological Protection (ICRP) in 1999. The mean field size over skin in typical panoramic and tomographic examinations was about 3% and 0.4% of the total body surface area of 15000 cm 2 . Assuming that the incidence of skin cancer is proportional to the area of skin exposed to ionizing radiation, the tissue weighting factor of skin can be estimated to be about 0.0003 and 0.00004. The estimate in effective dose was lower (5.3 μSv) in the panoramic auto function mode (an average exposure condition of 69 kV 7 mA) than that (6.5-13.8 μSv) in the linear tomogram modes. Since the linear tomogram mode requires a scout view, such as standard panoramic radiography, the dose in the linear tomogram mode becomes higher than other modes. A percentage of gonad doses in effective doses was negligible. (author)

  14. Effective dose to patients from thoracic spine examinations with tomosynthesis

    International Nuclear Information System (INIS)

    Svalkvist, Angelica; Baath, Magnus; Soederman, Christina

    2016-01-01

    The purposes of the present work were to calculate the average effective dose to patients from lateral tomosynthesis examinations of the thoracic spine, compare the results with the corresponding conventional examination and to determine a conversion factor between dose-area product (DAP) and effective dose for the tomosynthesis examination. Thoracic spine examinations from 17 patients were included in the study. The registered DAP and information about the field size for each projection radiograph were, together with patient height and mass, used to calculate the effective dose for each projection radiograph. The total effective doses for the tomosynthesis examinations were obtained by adding the effective doses from the 60 projection radiographs included in the examination. The mean effective dose was 0.47 mSv (range 0.24-0.81 mSv) for the tomosynthesis examinations and 0.20 mSv (range 0.07-0.29 mSv) for the corresponding conventional examinations (anteroposterior + left lateral projection). For the tomosynthesis examinations, a conversion factor between total DAP and effective dose of 0.092 mSv Gycm -2 was obtained. (authors)

  15. Cumulative radiation dose of multiple trauma patients during their hospitalization

    International Nuclear Information System (INIS)

    Wang Zhikang; Sun Jianzhong; Zhao Zudan

    2012-01-01

    Objective: To study the cumulative radiation dose of multiple trauma patients during their hospitalization and to analyze the dose influence factors. Methods: The DLP for CT and DR were retrospectively collected from the patients during June, 2009 and April, 2011 at a university affiliated hospital. The cumulative radiation doses were calculated by summing typical effective doses of the anatomic regions scanned. Results: The cumulative radiation doses of 113 patients were collected. The maximum,minimum and the mean values of cumulative effective doses were 153.3, 16.48 mSv and (52.3 ± 26.6) mSv. Conclusions: Multiple trauma patients have high cumulative radiation exposure. Therefore, the management of cumulative radiation doses should be enhanced. To establish the individualized radiation exposure archives will be helpful for the clinicians and technicians to make decision whether to image again and how to select the imaging parameters. (authors)

  16. Single event effects and total ionizing dose effects of typical VDMOSFET devices

    International Nuclear Information System (INIS)

    Lou Jianshe; Cai Nan; Liu Jiaxin; Wu Qinzhi; Wang Jia

    2012-01-01

    In this work, single event effects and total ionizing dose effects of typical VDMOSFET irradiated by 60 Co γ-rays and 252 Cf source were studied. The single event burnout and single event gate rupture (SEB/SEGR) effects were investigated, and the relationship between drain-source breakdown voltage and ionizing dose was obtained. The results showed that the VDMOSFET devices were sensitive to SEB and SEGR, and measures to improve their resistance to SEB and SEGR should be considered seriously for their space applications. The drain-source breakdown voltage was sensitive to total ionizing dose effects as the threshold voltage. In assessing the devices' resistance to the total ionizing dose effects, both the threshold voltage and the drain-source breakdown voltage should be taken into account. (authors)

  17. Effective dose from direct and indirect digital panoramic units

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Gun Sun; Kim, Jin Soo; Seo, Yo Seob; Kim, Jae Duk [School of Dentistry, Oral Biology Research Institute, Chosun University, Gwangju (Korea, Republic of)

    2013-06-15

    This study aimed to provide comparative measurements of the effective dose from direct and indirect digital panoramic units according to phantoms and exposure parameters. Dose measurements were carried out using a head phantom representing an average man (175 cm tall, 73.5 kg male) and a limbless whole body phantom representing an average woman (155 cm tall, 50 kg female). Lithium fluoride thermoluminescent dosimeter (TLD) chips were used for the dosimeter. Two direct and 2 indirect digital panoramic units were evaluated in this study. Effective doses were derived using 2007 International Commission on Radiological Protection (ICRP) recommendations. The effective doses of the 4 digital panoramic units ranged between 8.9 {mu}Sv and 37.8 {mu}Sv. By using the head phantom, the effective doses from the direct digital panoramic units (37.8 {mu}Sv, 27.6 {mu}Sv) were higher than those from the indirect units (8.9 {mu}Sv, 15.9 {mu}Sv). The same panoramic unit showed the difference in effective doses according to the gender of the phantom, numbers and locations of TLDs, and kVp. To reasonably assess the radiation risk from various dental radiographic units, the effective doses should be obtained with the same numbers and locations of TLDs, and with standard hospital exposure. After that, it is necessary to survey the effective doses from various dental radiographic units according to the gender with the corresponding phantom.

  18. Collective dose: Dogma, tool, or trauma?

    International Nuclear Information System (INIS)

    Becker, K.

    1996-01-01

    In Europe as well as in the United States, the argument continues in the radiation protection community between the open-quotes fundamentalists,close quotes who firmly believe in the linear no-threshold (LNT) hypothesis and the closely related concept of collective dose, and open-quotes pragmatists,close quotes who have serious doubts about these concepts for both radiobiological and socioeconomic reasons. The latter view is reflected in many recent compilations in the scientific literature, in particular in the books by G. Walinder and S. Kondo. The fundamentalist view has been expressed in other recent publications. What has been described as the good old boys' network of the establishment threatens nonbelievers with excommunication: in his 1996 Sievert lecture, D. Beninson described doubts about the LNT hypothesis as open-quotes arrogant ignoranceclose quotes; A. Gonzales, in a 1995 letter to the author, described them as open-quotes intellectual lazinessclose quotes; and R. Clarke, chairman of the International Commission on Radiological Protection (ICRP), during the 1996 IRPA Congress, described them as open-quotes seriously misguided.close quotes Threshold or no threshold, that is the question - the most important one for this and the next generation of health physicists. Corrections of the current dogmas are needed soon and should be initiated not only by the nuclear community (which may be blamed by opinion makers for a biased view) but by those members of the radiation protection community, who are not only interested in order to 'keep the hazard alive' for reasons of publicity, research funding, and sales of instruments and services. The International Atomic Energy Agency will devote a symposium to these questions next year. The results should be interesting

  19. Dose-rate effects on mammalian cells exposed to ionizing radiation

    International Nuclear Information System (INIS)

    Mitchell, J.B.

    1978-01-01

    The effect of irradiation on the life cycle and on cell survival was studied for a range of different dose rates. Log phase, plateau phase and synchronized cultures of different mammalian cells were used. Cell cycle redistribution during the radiation exposure was found to be a very important factor in determining the overall dose-rate effect for log phase and synchronized cells. In fact, cell cycle redistribution during the exposure, in some instances, resulted in a lower dose rate being more effective in cell killing per unit dose than a higher dose rate. For plateau phase cultures, where cell cycle times are greatly lengthened, the effects of redistribution in regard to cell killing was virtually eliminated. Both fed and unfed plateau phase cultures exhibited a dose-rate effect, but it was found that below dose rates of 154 rad/h there is no further loss in effectiveness

  20. Dose Rate Effects in Linear Bipolar Transistors

    Science.gov (United States)

    Johnston, Allan; Swimm, Randall; Harris, R. D.; Thorbourn, Dennis

    2011-01-01

    Dose rate effects are examined in linear bipolar transistors at high and low dose rates. At high dose rates, approximately 50% of the damage anneals at room temperature, even though these devices exhibit enhanced damage at low dose rate. The unexpected recovery of a significant fraction of the damage after tests at high dose rate requires changes in existing test standards. Tests at low temperature with a one-second radiation pulse width show that damage continues to increase for more than 3000 seconds afterward, consistent with predictions of the CTRW model for oxides with a thickness of 700 nm.

  1. Estimation of effective dose equivalente from external irradiations

    International Nuclear Information System (INIS)

    Wakabayashi, T.

    1985-07-01

    A methodology for computing effective dose equivalent, derived from the computer code ALGAM: Monte Carlo Estimation of Internal Dose from Gamma-ray Sources in a Phantom Man, developed at Oak Ridge National Laboratory, is presented. The modified code was run for 12 different photon energy levels, from 0,010 Mev to 4.0 Mev, which provides computing the absorved dose, for these energy levels, in each one of the 97 organs of the original code. The code also was run for the principal energy levels used in the calibration of the dosimetric films. The results of the absorved doses per photon obtained for these levels of energy have been transformed in effective dose equivalents. (M.A.C.) [pt

  2. Implications of effects ''adaptive response'', ''low-dose hypersensitivity'' und ''bystander effect'' for cancer risk at low doses and low dose rates

    International Nuclear Information System (INIS)

    Jacob, P

    2006-01-01

    A model for carcinogenesis (the TSCE model) was applied in order to examine the effects of ''Low-dose hypersensitivity (LDH)'' and the ''Bystander effect (BE)'' on the derivation of radiation related cancer mortality risks. LDH has been discovered to occur in the inactivation of cells after acute exposure to low LET radiation. A corresponding version of the TSCE model was applied to the mortality data on the Abomb survivors from Hiroshima and Nagasaki. The BE has been mainly observed in cells after exposure to high LET radiation. A Version of the TSCE model which included the BE was applied to the data on lung cancer mortality from the workers at the Mayak nuclear facilities who were exposed to Plutonium. In general an equally good description of the A-bomb survivor mortality data (for all solid, stomach and lung tumours) was found for the TSCE model and the (conventional) empirical models but fewer parameters were necessary for the TSCE model. The TSCE model which included the effects of radiation induced cell killing resulted in non-linear dose response curves with excess relative risks after exposure at young ages that were generally lower than in the models without cell killing. The main results from TSCE models which included cell killing described by either conventional survival curves or LDH were very similar. A sub multiplicative effect from the interaction of smoking and exposure to plutonium was found to result from the analysis of the Mayak lung cancer mortality data. All models examined resulted in the predominant number of Mayak lung cancer deaths being ascribed to smoking. The interaction between smoking and plutonium exposures was found to be the second largest effect. The TSCE model resulted in lower estimates for the lung cancer excess relative risk per unit plutonium dose than the empirical risk model, but this difference was not found to be statistically significant. The excess relative risk dose responses were linear in the empirical model and

  3. The effectiveness of low-dose and high-dose tranexamic acid in posterior lumbar interbody fusion: a double-blinded, placebo-controlled randomized study.

    Science.gov (United States)

    Kim, Ki-Tack; Kim, Cheung-Kue; Kim, Yong-Chan; Juh, Hyung-Suk; Kim, Hyo-Jong; Kim, Hyeon-Soo; Hong, Se Jung; Hey, Hwee Weng Dennis

    2017-11-01

    Tranexamic acid is a proven drug used for reduction of intraoperative blood loss in spinal surgery. However, optimal dosing considering risk/benefits is not well established owing to the heterogeneity in patient selection and surgical procedures of previous studies. This study aimed to evaluate the effectiveness and safety of various tranexamic acid regimens in reducing perioperative blood loss in single-level posterior lumbar interbody fusion (PLIF). Patients were randomly grouped into three different interventions: low-dose tranexamic acid (LD), high-dose tranexamic acid (HD), and placebo-controlled (PC) groups. The HD and LD groups received 10 and 5 mg/kg of bolus loading dose and 2 and 1 mg/kg of continuous infusion until 5 h after surgery, respectively. Data on patient demographics and preoperative and 24-h postoperative laboratory values were collected. Outcome parameters include intraoperative blood loss, 24-h postoperative blood loss, and blood loss during removal of the last drain. Seventy-two patients (mean age 63.3 ± 7.6 years) showed similar baseline characteristics. Intraoperatively, blood loss was reduced by the administration of tranexamic acid (P = 0.04), contributed predominantly by a difference between the LD and HD groups (123 mL; P tranexamic acid use were noted. Tranexamic acid administration for single-level PLIF was effective and safe in reducing perioperative blood loss in a dose-dependent manner. An HD regimen comprising 10 mg/kg of bolus loading dose and 2 mg/kg/h of continuous infusion is recommended. Level 1 study according to Oxford Centre for Evidence-Based Medicine 2011 Levels of Evidence.

  4. Estimating effective doses to children from CT examinations

    International Nuclear Information System (INIS)

    Heron, J.C.L.

    2000-01-01

    Full text: Assessing doses to patients in diagnostic radiology is an integral part of implementing optimisation of radiation protection. Sources of normalised data are available for estimating doses to adults undergoing CT examinations, but for children this is not the case. This paper describes a simple method for estimating effective doses arising from paediatric CT examinations. First the effective dose to an adult is calculated, having anatomically matched the scanned regions of the child and the adult and also matched the irradiation conditions. A conversion factor is then applied to the adult effective dose, based on the region of the body being scanned - head, upper or lower trunk. This conversion factor is the child-to-adult ratio of the ratios of effective dose per entrance air kerma (in the absence of the patient) at the FAD. The values of these conversion factors were calculated by deriving effective dose per entrance air kerma at the FAD for new-born, 1, 5, 10, 15 and adult phantoms using four projections (AP, PA, left and right laterals) over a range of beam qualities and FADs.The program PCXMC was used for this purpose. Results to date suggest that the conversion factors to give effective doses for children undergoing CT examinations of the upper trunk are approximately 1.3, 1.2, 1.15, 1.1 and 1.05 for ages 0, 1, 5, 10 and 15 years respectively; CT of the lower trunk - 1.4, 1.3, 1.2, 1.2, 1.1; and CT of the head - 2.3, 2.0, 1.5, 1.3, 1.1. The dependence of these factors on beam quality (HVL from 4 to 10 mm Al) is less than 10%, with harder beams resulting in slightly smaller conversion factors. Dependence on FAD is also less than 10%. Major sources of uncertainties in the conversion factors include matching anatomical regions across the phantoms, and the presence of beam divergence in the z-direction when deriving the factors. The method described provides a simple means of estimating effective doses arising from paediatric CT examinations with

  5. Mathematical model for evaluation of dose-rate effect on biological responses to low dose γ-radiation

    International Nuclear Information System (INIS)

    Ogata, H.; Kawakami, Y.; Magae, J.

    2003-01-01

    Full text: To evaluate quantitative dose-response relationship on the biological response to radiation, it is necessary to consider a model including cumulative dose, dose-rate and irradiation time. In this study, we measured micronucleus formation and [ 3 H] thymidine uptake in human cells as indices of biological response to gamma radiation, and analyzed mathematically and statistically the data for quantitative evaluation of radiation risk at low dose/low dose-rate. Effective dose (ED x ) was mathematically estimated by fitting a general function of logistic model to the dose-response relationship. Assuming that biological response depends on not only cumulative dose but also dose-rate and irradiation time, a multiple logistic function was applied to express the relationship of the three variables. Moreover, to estimate the effect of radiation at very low dose, we proposed a modified exponential model. From the results of fitting curves to the inhibition of [ 3 H] thymidine uptake and micronucleus formation, it was obvious that ED 50 in proportion of inhibition of [ 3 H] thymidine uptake increased with longer irradiation time. As for the micronuclei, ED 30 also increased with longer irradiation times. These results suggest that the biological response depends on not only total dose but also irradiation time. The estimated response surface using the three variables showed that the biological response declined sharply when the dose-rate was less than 0.01 Gy/h. These results suggest that the response does not depend on total cumulative dose at very low dose-rates. Further, to investigate the effect of dose-rate within a wider range, we analyzed the relationship between ED x and dose-rate. Fitted curves indicated that ED x increased sharply when dose-rate was less than 10 -2 Gy/h. The increase of ED x signifies the decline of the response or the risk and suggests that the risk approaches to 0 at infinitely low dose-rate

  6. EFFECTIVE DOSE TO PATIENTS FROM THORACIC SPINE EXAMINATIONS WITH TOMOSYNTHESIS.

    Science.gov (United States)

    Svalkvist, Angelica; Söderman, Christina; Båth, Magnus

    2016-06-01

    The purposes of the present work were to calculate the average effective dose to patients from lateral tomosynthesis examinations of the thoracic spine, compare the results with the corresponding conventional examination and to determine a conversion factor between dose-area product (DAP) and effective dose for the tomosynthesis examination. Thoracic spine examinations from 17 patients were included in the study. The registered DAP and information about the field size for each projection radiograph were, together with patient height and mass, used to calculate the effective dose for each projection radiograph. The total effective doses for the tomosynthesis examinations were obtained by adding the effective doses from the 60 projection radiographs included in the examination. The mean effective dose was 0.47 mSv (range 0.24-0.81 mSv) for the tomosynthesis examinations and 0.20 mSv (range 0.07-0.29 mSv) for the corresponding conventional examinations (anteroposterior + left lateral projection). For the tomosynthesis examinations, a conversion factor between total DAP and effective dose of 0.092 mSv Gycm(-2) was obtained. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  7. Developmental neurotoxic effects of a low dose of TCE on a 3-D neurosphere system.

    Science.gov (United States)

    Abdraboh, M E; Abdeen, S H; Salama, M; El-Husseiny, M; El-Sherbini, Y M; Eldeen, N M

    2018-02-01

    Trichloroethylene (TCE) is one of the industrial toxic byproducts that now persist in the air, soil, and water. Several studies have already illustrated the toxic effect of high doses of TCE on the biological functions of several organs. This study aims to highlight the toxic impact of a low dose of TCE (1 μmol/L) on the development of rat neural stem cells (NSCs). The subventricular zones (SVZ) of rat pup's brains were collected and minced, and the harvested cells were cultured in the presence of neural growth factors B27/N2 to develop neurospheres. The cells were then exposed to a dose of 1 μmol/L TCE for 1 or 2 weeks. The outcomes indicated a remarkable inhibitory effect of TCE on the differentiation capacity of NSCs, which was confirmed by down-regulation of the astrocyte marker GFAP The inhibitory effect of TCE on the proliferation of NSCs was identified by the reductions in neurosphere diameter, Ki67 expression, and cell cycle arrest at the G1/S phase. Immunolabelling with annexin V indicated the proapoptotic effect of TCE exposure. PCR results revealed a TCE-mediated suppression of the expression of the antioxidant enzyme SOD1. This paper illustrates, for the first time, a detailed examination of the toxic effects of an environmentally low dose of TCE on NCSs at the transcriptional, translational, and functional levels.

  8. Low-dose effects of bisphenol A on mammary gland development in rats

    DEFF Research Database (Denmark)

    Egebjerg, Karen Mandrup; Boberg, Julie; Isling, Louise Krag

    2016-01-01

    was to perform a study robust enough to contribute to the risk assessment of BPA and to elucidate possible biphasic dose–response relationships. We investigated mammary gland effects in the offspring at 22, 100, and 400 days of age. Male offspring showed increased mammary outgrowth on pup day (PD) 22 at 0.025 mg...... intraductal hyperplasia in female rats could be associated with an increased risk for developing hyperplastic lesions, which are parallels to early signs of breast neoplasia in women. Collectively, current knowledge on effects of BPA on mammary gland at low doses indicates that highly exposed humans may...

  9. Cocaine and Pavlovian fear conditioning: dose-effect analysis.

    Science.gov (United States)

    Wood, Suzanne C; Fay, Jonathan; Sage, Jennifer R; Anagnostaras, Stephan G

    2007-01-25

    Emerging evidence suggests that cocaine and other drugs of abuse can interfere with many aspects of cognitive functioning. The authors examined the effects of 0.1-15mg/kg of cocaine on Pavlovian contextual and cued fear conditioning in mice. As expected, pre-training cocaine dose-dependently produced hyperactivity and disrupted freezing. Surprisingly, when the mice were tested off-drug later, the group pre-treated with a moderate dose of cocaine (15mg/kg) displayed significantly less contextual and cued memory, compared to saline control animals. Conversely, mice pre-treated with a very low dose of cocaine (0.1mg/kg) showed significantly enhanced fear memory for both context and tone, compared to controls. These results were not due to cocaine's anesthetic effects, as shock reactivity was unaffected by cocaine. The data suggest that despite cocaine's reputation as a performance-enhancing and anxiogenic drug, this effect is seen only at very low doses, whereas a moderate dose disrupts hippocampus and amygdala-dependent fear conditioning.

  10. Estimation and comparison of effective dose (E) in standard chest CT by organ dose measurements and dose-length-product methods and assessment of the influence of CT tube potential (energy dependency) on effective dose in a dual-source CT

    International Nuclear Information System (INIS)

    Paul, Jijo; Banckwitz, Rosemarie; Krauss, Bernhard; Vogl, Thomas J.; Maentele, Werner; Bauer, Ralf W.

    2012-01-01

    Highlights: ► The dual-energy protocol delivers the lowest effective dose of the investigated protocols for standard chest CT examinations, thus enabling functional imaging (like dual-energy perfusion) and can produce weighted images without dose penalty. ► The high-pitch protocol goes along with a 16% increase in dose compared to the standard 120 kV protocol and thus should preferably be used in pediatric, acute care settings (e.g. pulmonary embolism, aortic dissection and the like) or restless patients. ► The difference in effective dose estimates between ICRP 60 and 103 is minimal. ► Tube potential definitely has an effect on estimates of effective dose. - Abstract: Purpose: To determine effective dose (E) during standard chest CT using an organ dose-based and a dose-length-product-based (DLP) approach for four different scan protocols including high-pitch and dual-energy in a dual-source CT scanner of the second generation. Materials and methods: Organ doses were measured with thermo luminescence dosimeters (TLD) in an anthropomorphic male adult phantom. Further, DLP-based dose estimates were performed by using the standard 0.014 mSv/mGycm conversion coefficient k. Examinations were performed on a dual-source CT system (Somatom Definition Flash, Siemens). Four scan protocols were investigated: (1) single-source 120 kV, (2) single-source 100 kV, (3) high-pitch 120 kV, and (4) dual-energy with 100/Sn140 kV with equivalent CTDIvol and no automated tube current modulation. E was then determined following recommendations of ICRP publication 103 and 60 and specific k values were derived. Results: DLP-based estimates differed by 4.5–16.56% and 5.2–15.8% relatively to ICRP 60 and 103, respectively. The derived k factors calculated from TLD measurements were 0.0148, 0.015, 0.0166, and 0.0148 for protocol 1, 2, 3 and 4, respectively. Effective dose estimations by ICRP 103 and 60 for single-energy and dual-energy protocols show a difference of less than 0.04 m

  11. Adult head CT scans: the uncertainties of effective dose estimates

    International Nuclear Information System (INIS)

    Gregory, Kent J.; Bibbo, Giovanni; Pattison, John E.

    2008-01-01

    Full Text: CT scanning is a high dose imaging modality. Effective dose estimates from CT scans can provide important information to patients and medical professionals. For example, medical practitioners can use the dose to estimate the risk to the patient, and judge whether this risk is outweighed by the benefits of the CT examination, while radiographers can gauge the effect of different scanning protocols on the patient effective dose, and take this into consideration when establishing routine scan settings. Dose estimates also form an important part of epidemiological studies examining the health effects of medical radiation exposures on the wider population. Medical physicists have been devoting significant effort towards estimating patient radiation doses from diagnostic CT scans for some years. The question arises: How accurate are these effective dose estimates? The need for a greater understanding and improvement of the uncertainties in CT dose estimates is now gaining recognition as an important issue (BEIR VII 2006). This study is an attempt to analyse and quantify the uncertainty components relating to effective dose estimates from adult head CT examinations that are calculated with four commonly used methods. The dose estimation methods analysed are the Nagel method, the ImpaCT method, the Wellhoefer method and the Dose-Length Product (DLP) method. The analysis of the uncertainties was performed in accordance with the International Standards Organisation's Guide to the Expression of Uncertainty in Measurement as discussed in Gregory et al (Australas. Phys. Eng. Sci. Med., 28: 131-139, 2005). The uncertainty components vary, depending on the method used to derive the effective dose estimate. Uncertainty components in this study include the statistical and other errors from Monte Carlo simulations, uncertainties in the CT settings and positions of patients in the CT gantry, calibration errors from pencil ionization chambers, the variations in the organ

  12. Optimisation need of dental radiodiagnostic procedures: results of effective dose evaluation from Rando phantom measurements

    International Nuclear Information System (INIS)

    Borio, R.; Chiocchini, S.; Cicioni, R.; Degli Esposti, P.; Rongoni, A.; Sabatini, P.; Saetta, D.M.S.; Regi, L.; Caprino, G.

    1994-01-01

    Radiological examinations of different types are needed in dental practice both to make a correct diagnosis and to carry out an adequate therapy. Particularly in orthodentic practices, because of the youth of the majority of the patients, an assessment of the detriment to health (through the effective dose equivalent) caused by medical diagnostic exposure to ionising radiation is needed to make decisions about the optimisation of dental radiodiagnostic procedures. Experimental data from measurements on a Rando phantom were collected for the radiological examinations required for dental and for orthodontic practices (with and without protective apron and collar). The results show the effectiveness of the leaded apron and collar in all the examinations carried out, particularly in reducing thyroid dose. (author)

  13. Dose and dose rate effects of whole-body gamma-irradiation: II. Hematological variables and cytokines

    Science.gov (United States)

    Gridley, D. S.; Pecaut, M. J.; Miller, G. M.; Moyers, M. F.; Nelson, G. A.

    2001-01-01

    The goal of part II of this study was to evaluate the effects of gamma-radiation on circulating blood cells, functional characteristics of splenocytes, and cytokine expression after whole-body irradiation at varying total doses and at low- and high-dose-rates (LDR, HDR). Young adult C57BL/6 mice (n = 75) were irradiated with either 1 cGy/min or 80 cGy/min photons from a 60Co source to cumulative doses of 0.5, 1.5, and 3.0 Gy. The animals were euthanized at 4 days post-exposure for in vitro assays. Significant dose- (but not dose-rate-) dependent decreases were observed in erythrocyte and blood leukocyte counts, hemoglobin, hematocrit, lipopolysaccharide (LPS)-induced 3H-thymidine incorporation, and interleukin-2 (IL-2) secretion by activated spleen cells when compared to sham-irradiated controls (p < 0.05). Basal proliferation of leukocytes in the blood and spleen increased significantly with increasing dose (p < 0.05). Significant dose rate effects were observed only in thrombocyte counts. Plasma levels of transforming growth factor-beta 1 (TGF-beta 1) and splenocyte secretion of tumor necrosis factor-alpha (TNF-alpha) were not affected by either the dose or dose rate of radiation. The data demonstrate that the responses of blood and spleen were largely dependent upon the total dose of radiation employed and that an 80-fold difference in the dose rate was not a significant factor in the great majority of measurements.

  14. Dose rate reduction using epoxy mixed lead shielding: experimental and theoretical determination of its shielding effectiveness

    International Nuclear Information System (INIS)

    Yadav, R.K.B.; Prasad, S.K.; Babu, K.S.; Hardiya, M.R.; Ullas, O.P.

    2010-01-01

    Full text: High background radiation field exists in Water Treatment Area (WTA) of Rod Cutting Building (RCB) in Cirus due to beta, gamma contamination on its floor. The high contamination on sides of wall and on floor is primarily due to deposition of activity generated during the regeneration of old mixed bed cartridges earlier (before year 1985) and presently due to deposition of contaminants by sump overflowing, wastes generated during maintenance/servicing of circulating pumps. RCB-WTA contribution to collective dose in present situation is up to 30% of the total collective dose of Cirus. Various options such as chipping of top layer of concrete floor of a sample area, in-situ placing of slab of cement and lead shot mixture were considered. In this case the man-rem consumption was high as radiation dose rate on concrete chip was 0.4 mGy/h and air activity generated was high, that too long lived with 137 Cs-as main constituent. The dose reduction factor was 1.7. In the second option the reduction in dose rate was insignificant and in-situ pouring of concrete consumed high collective dose. Hence above two options were not acceptable. Therefore the idea of tiling the contaminated floor with prefabricated epoxy mixed lead shots was accepted from ALARA point of view. It was concluded that pre-fabricated slabs of epoxy mixed lead slab of 25 mm thickness can be laid in RCB area to achieve a dose rate reduction factor of approximately five at a height of 30 cm above floor. This will result in a reduction of Person-mSv consumption in RCB by a factor of 5-10. These slabs of different thickness were fabricated outside RCB and were tested for shielding effectiveness experimentally by using radiation source and theoretically using MCNP code. Dose reduction factor of five for a point source, obtained experimentally for epoxy mixed lead shots was very near to value obtained by theoretical simulation. An extended calculation for an area source using this MCNP model gives a

  15. Uncertainty on faecal analysis on dose assessment

    Energy Technology Data Exchange (ETDEWEB)

    Juliao, Ligia M.Q.C.; Melo, Dunstana R.; Sousa, Wanderson de O.; Santos, Maristela S.; Fernandes, Paulo Cesar P. [Instituto de Radioprotecao e Dosimetria, Comissao Nacional de Energia Nuclear, Av. Salvador Allende s/n. Via 9, Recreio, CEP 22780-160, Rio de Janeiro, RJ (Brazil)

    2007-07-01

    Monitoring programmes for internal dose assessment may need to have a combination of bioassay techniques, e.g. urine and faecal analysis, especially in workplaces where compounds of different solubilities are handled and also in cases of accidental intakes. Faecal analysis may be an important data for assessment of committed effective dose due to exposure to insoluble compounds, since the activity excreted by urine may not be detectable, unless a very sensitive measurement system is available. This paper discusses the variability of the daily faecal excretion based on data from just one daily collection; collection during three consecutive days: samples analysed individually and samples analysed as a pool. The results suggest that just 1 d collection is not appropriate for dose assessment, since the 24 h uranium excretion may vary by a factor of 40. On the basis of this analysis, the recommendation should be faecal collection during three consecutive days, and samples analysed as a pool, it is more economic and faster. (authors)

  16. Shielding calculations and collective dose estimations with the point-kernel-code VISIPLAN registered for the example of the project ZENT

    International Nuclear Information System (INIS)

    Boehlke, S.; Niegoth, H.

    2012-01-01

    In the nuclear power plant Leibstadt (KKL) during the next year large components will be dismantled and stored for final disposal within the interim storage facility ZENT at the NPP site. Before construction of ZENT appropriate estimations of the local dose rate inside and outside the building and the collective dose for the normal operation have to be performed. The shielding calculations are based on the properties of the stored components and radiation sources and on the concepts for working place requirements. The installation of control and monitoring areas will depend on these calculations. For the determination of the shielding potential of concrete walls and steel doors with the defined boundary conditions point-kernel codes like MICROSHIELd registered are used. Complex problems cannot be modeled with this code. Therefore the point-kernel code VISIPLAN registered was developed for the determination of the local dose distribution functions in 3D models. The possibility of motion sequence inputs allows an optimization of collective dose estimations for the operational phases of a nuclear facility.

  17. The MLC tongue-and-groove effect on IMRT dose distributions

    Energy Technology Data Exchange (ETDEWEB)

    Deng Jun [Department of Radiation Oncology, Stanford University School of Medicine, Stanford, CA 94305 (United States). E-mail: jun@reyes.stanford.edu; Pawlicki, Todd; Chen Yan; Li Jinsheng; Jiang, Steve B.; Ma, C.-M. [Department of Radiation Oncology, Stanford University School of Medicine, Stanford, CA 94305 (United States)

    2001-04-01

    We have investigated the tongue-and-groove effect on the IMRT dose distributions for a Varian MLC. We have compared the dose distributions calculated using the intensity maps with and without the tongue-and-groove effect. Our results showed that, for one intensity-modulated treatment field, the maximum tongue-and-groove effect could be up to 10% of the maximum dose in the dose distributions. For an IMRT treatment with multiple gantry angles ({>=} 5), the difference between the dose distributions with and without the tongue-and-groove effect was hardly visible, less than 1.6% for the two typical clinical cases studied. After considering the patient setup errors, the dose distributions were smoothed with reduced and insignificant differences between plans with and without the tongue-and-groove effect. Therefore, for a multiple-field IMRT plan ({>=} 5), the tongue-and-groove effect on the IMRT dose distributions will be generally clinically insignificant due to the smearing effect of individual fields. The tongue-and-groove effect on an IMRT plan with small number of fields (<5) will vary depending on the number of fields in a plan (coplanar or non-coplanar), the MLC leaf sequences and the patient setup uncertainty, and may be significant (>5% of maximum dose) in some cases, especially when the patient setup uncertainty is small ({<=} 2 mm). (author)

  18. Committed effective dose from naturally occuring radionuclides in shellfish

    International Nuclear Information System (INIS)

    Khandaker, Mayeen Uddin; Wahib, Norfadira Binti; Amin, Yusoff Mohd.; Bradley, D.A.

    2013-01-01

    Recognizing their importance in the average Malaysian daily diet, the radioactivity concentrations in mollusc- and crustacean-based food have been determined for key naturally occuring radionuclides. Fresh samples collected from various maritime locations around peninsular Malaysia have been processed using standard procedures; the radionuclide concentrations being determined using an HPGe γ-ray spectrometer. For molluscs, assuming secular equilibrium, the range of activities of 238 U ( 226 Ra), 232 Th ( 228 Ra) and 40 K were found to be 3.28±0.35 to 5.34±0.52, 1.20±0.21 to 2.44±0.21 and 118±6 to 281±14 Bq kg −1 dry weight, respectively. The respective values for crustaceans were 3.02±0.57 to 4.70±0.52, 1.38±0.21 to 2.40±0.35 and 216±11 to 316±15 Bq kg −1 . The estimated average daily intake of radioactivity from consumption of molluscs are 0.37 Bq kg −1 for 238 U ( 226 Ra), 0.16 Bq kg −1 for 232 Th ( 228 Ra) and 18 Bq kg −1 for 40 K; the respective daily intake values from crustaceans are 0.36 Bq kg −1 , 0.16 Bq kg −1 and 23 Bq kg −1 . Associated annual committed effective doses from molluscs are estimated to be in the range 21.3 to 34.7 μSv for 226 Ra, 19.3 to 39.1 μSv for 228 Ra and 17.0 to 40.4 μSv for 40 K. For crustaceans, the respective dose ranges are 19.6 to 30.5 μSv, 22.0 to 38.4 μSv and 31.1 to 45.5 μSv, being some several times world average values. - Highlights: ► Activity concentrations of naturally occuring radionuclides were assessed for shellfish. ► 238 U, 232 Th, 40 K intake via shellfish showed several times higher than world averages. ► Committed effective doses due to the ingestions of 238 U, 232 Th, 40 K are the first report in Malaysia. ► Estimated committed effective dose also showed higher values than the world average

  19. Study of the IMRT interplay effect using a 4DCT Monte Carlo dose calculation.

    Science.gov (United States)

    Jensen, Michael D; Abdellatif, Ady; Chen, Jeff; Wong, Eugene

    2012-04-21

    Respiratory motion may lead to dose errors when treating thoracic and abdominal tumours with radiotherapy. The interplay between complex multileaf collimator patterns and patient respiratory motion could result in unintuitive dose changes. We have developed a treatment reconstruction simulation computer code that accounts for interplay effects by combining multileaf collimator controller log files, respiratory trace log files, 4DCT images and a Monte Carlo dose calculator. Two three-dimensional (3D) IMRT step-and-shoot plans, a concave target and integrated boost were delivered to a 1D rigid motion phantom. Three sets of experiments were performed with 100%, 50% and 25% duty cycle gating. The log files were collected, and five simulation types were performed on each data set: continuous isocentre shift, discrete isocentre shift, 4DCT, 4DCT delivery average and 4DCT plan average. Analysis was performed using 3D gamma analysis with passing criteria of 2%, 2 mm. The simulation framework was able to demonstrate that a single fraction of the integrated boost plan was more sensitive to interplay effects than the concave target. Gating was shown to reduce the interplay effects. We have developed a 4DCT Monte Carlo simulation method that accounts for IMRT interplay effects with respiratory motion by utilizing delivery log files.

  20. Organ doses and effective doses in some medical and industrial applications

    International Nuclear Information System (INIS)

    Keshavkumar, Biju

    2000-01-01

    The ICRP recommends radiation protection standards for the safe use of radiation and also prescribes the radiation protection quantities and periodically reviews them. In this context, the quantities like organ doses and effective doses are defined by ICRP. In this work we calculate these quantities and hence the conversion functions for the industrial radiation sources and those for CT and diagnostic X-ray exposures. Workers who are occupationally exposed to radiation are regularly monitored to evaluate the radiation dose received by them. It is quite possible that in an accident situation, the worker involved in the accident might not have worn a personal monitor, popularly known as the monitoring badge. In addition, even some non radiation workers (who are obviously not monitored) may also have received exposure. Under these circumstances, the persons involved are interviewed, the accident site inspected, and on the basis of realistic assumptions, the likely doses received by the exposed persons are estimated

  1. The estimation of occupational effective dose in diagnostic radiology with two dosimeters

    International Nuclear Information System (INIS)

    Niklason, L.T.; Marx, M.V.; Chan, Heang-Ping

    1994-01-01

    Annual effective dose limits have been proposed by national and international radiation protection committees. Radiation protection agencies must decide upon a method of converting the radiation dose measured from dosimeters to an estimate of effective dose. A proposed method for the estimation of effective dose from the radiation dose to two dosimeters is presented. Correction factors are applied to an over-apron collar dose and an under-apron dose to estimate the effective dose. Correction factors are suggested for two cases, both with and without a thyroid shield. Effective dose may be estimated by the under-apron dose plus 6% of the over-collar dose if a thyroid shield is not worn or plus 2% of the over-collar dose if a thyroid shield is worn. This method provides a reasonable estimate of effective dose that is independent of lead apron thickness and accounts for the use of a thyroid shield. 17 refs., 3 tabs

  2. [Dose rate-dependent cellular and molecular effects of ionizing radiation].

    Science.gov (United States)

    Przybyszewski, Waldemar M; Wideł, Maria; Szurko, Agnieszka; Maniakowski, Zbigniew

    2008-09-11

    The aim of radiation therapy is to kill tumor cells while minimizing damage to normal cells. The ultimate effect of radiation can be apoptotic or necrotic cell death as well as cytogenetic damage resulting in genetic instability and/or cell death. The destructive effects of radiation arise from direct and indirect ionization events leading to peroxidation of macromolecules, especially those present in lipid-rich membrane structures as well as chromatin lipids. Lipid peroxidative end-products may damage DNA and proteins. A characteristic feature of radiation-induced peroxidation is an inverse dose-rate effect (IDRE), defined as an increase in the degree of oxidation(at constant absorbed dose) accompanying a lower dose rate. On the other hand, a low dose rate can lead to the accumulation of cells in G2, the radiosensitive phase of the cell cycle since cell cycle control points are not sensitive to low dose rates. Radiation dose rate may potentially be the main factor improving radiotherapy efficacy as well as affecting the intensity of normal tissue and whole-body side effects. A better understanding of dose rate-dependent biological effects may lead to improved therapeutic intervention and limit normal tissue reaction. The study reviews basic biological effects that depend on the dose rate of ionizing radiation.

  3. The analysis of activities of the pharmaceuticals and of the radiation dose to population in Slovakia from diagnosis in nuclear medicine

    International Nuclear Information System (INIS)

    Ftacnikova, S.

    1996-01-01

    A survey of the following quantities was performed at Slovak nuclear medicine departments: administered activity (range and mean value) of radiopharmaceuticals, broken down by the kind of examination; collective effective dose and mean effective dose per examination and per capita in comparison with other countries; summary of examinations and annual collective dose contributions broken down by the major radionuclides; and comparison of the effective doses H E and collective effective doses S E in adults from diagnostic radiopharmaceuticals calculated by using the ICRP weighting factors. The summary values are as follows: the effective dose from diagnostic pharmaceuticals was 3.8 mSv per examination and 0.022 mSv per capita, the collective effective dose was 110.7 manSv. It is concluded that there are large differences between the activities administered by the various nuclear medicine departments in the country, which deserves more detailed examination. The per capita mean effective dose is several times lower in the Slovak Republic than in other comparable countries. (P.A.). 4 tabs., 10 refs

  4. Dose and dose rate effects on coherent-to-incoherent transition of precipitates upon irradiation

    Institute of Scientific and Technical Information of China (English)

    LI Zhengchao

    2006-01-01

    A typical precipitation hardened alloy, Cu-Co dilute alloy was selected to study the precipitation behavior and irradiation effect on precipitates. It is found that the principal effect of ion irradiation on the coherent precipitates is loss of coherency, and TEM cross-section observations show that the fraction of the incoherent precipitates is dependent on dose but not on dose rate during heavy ion irradiation.

  5. Low dose effects of ionizing radiations in in vitro and in vivo biological systems: a multi-scale approach study

    International Nuclear Information System (INIS)

    Antoccia, A.; Berardinelli, F.; Argazzi, E.; Balata, M.; Bedogni, R.

    2011-01-01

    Long-term biological effects of low-dose radiation are little known nowadays and its carcinogenic risk is estimated on the assumption that risk remains linearly proportional to the radiation dose down to low-dose levels. However in the last 20 years this hypothesis has gradually begun to seem in contrast with a huge collection of experimental evidences, which has shown the presence of plethora of non-linear phenomena (including hypersensitivity and induced radioresistance, adaptive response, and non-targeted phenomena like bystander effect and genomic instability) occurring after low-dose irradiation. These phenomena might imply a non-linear behaviour of cancer risk curves in the low-dose region and question the validity of the Linear No-Threshold (LNT) model currently used for cancer risk assessment through extrapolation from existing high-dose data. Moreover only few information is available regarding the effects induced on cryo preserved cells by multi-year background radiation exposure, which might induce a radiation-damage accumulation, due to the inhibition of cellular repair mechanisms. In this framework, the multi-year Excalibur (Exposure effects at low doses of ionizing radiation in biological culture) experiment, funded by INFN-CNS5, has undertaken a multi-scale approach investigation on the biological effects induced in in vitro and in vivo biological systems, in culture and cryo preserved conditions, as a function of radiation quality (X/γ-rays, protons, He-4 ions of various energies) and dose, with particular emphasis on the low-dose region and non-linear phenomena, in terms of different biological endpoints.

  6. Occupational dose trends in Tanzania

    International Nuclear Information System (INIS)

    Muhogora, W.E.; Nyanda, A.M.; Ngaile, J.E.; Lema, U.S.

    1998-01-01

    This paper describes the present status of occupational radiation exposure of monitored workers in Tanzania from 1986 to 1997. The analysis of dose records observes over this period, a fluctuating trend both in the individual and collective doses. The trend is more related to the fluctuations of the number of radiation workers than to the possible radiation safety changes of the working conditions. It has been found that, the maximum annual dose for the worker in all work categories was about 18 mSv y -1 . This suggests that the occupational radiation exposure in all practices satisfies the current dose limitation system. The national exposure summary shows that, the highest collective dose of 12.8 man-Sv which is 90% of the total collective dose, was due to medical applications. The applications in industry and research had a contribution of nearly 0.8 and 0.7 man-Sv respectively. From the professional point of view, the medical diagnostic radiographers received the highest collective dose of 11.2 man-Sv. Although the medical physicists recorded the minimum collective dose of nearly 0.07 man-Sv, the data shows that this profession received the highest mean dose of about 33 mSv in 12 years. Some achievements of the personnel monitoring services and suggestions for future improvement are pointed out. (author)

  7. Effectance, committed effective dose equivalent and annual limits on intake: what are the changes?

    International Nuclear Information System (INIS)

    Kendall, G.M.; Stather, J.W.; Phipps, A.W.

    1990-01-01

    This paper outlines the concept of effectance, compares committed effectance with the old committed effective dose equivalent and goes on to discuss changes in the annual limits on intakes and the maximum organ doses which would result from an intake of an ALI (Annual Limit of Intake). It is shown that committed effectance is usually, but not always, higher than committed effective dose equivalent. ALIS are usually well below those resulting from the ICRP Publication 30 scheme. However, if the ALI were based only on a limit on effectance it would imply a high dose to specific organs for certain nuclides. In order to control maximum organ doses an explicit limit could be introduced. However, this would destroy some of the attractive features of the new scheme. An alternative would be a slight modification to some of the weighting factors. (author)

  8. Biological effect of Pulsed Dose Rate brachytherapy with stepping sources

    International Nuclear Information System (INIS)

    Limbergen, Erik F.M. van; Fowler, Jack F.

    1996-01-01

    Purpose: To explore the possible increase of radiation effect in tissues irradiated by pulsed brachytherapy (PDR), for local tissue dose-rates between those 'averaged over the whole pulse' and the instantaneous high dose rates close to the dwell positions. An earlier publication (Fowler and Mount 1992) had shown that, for dose rates (averaged for the duration of the pulse) up to 3 Gy/h, little change of isoeffect doses from continuous low dose rate (CLDR) are expected, unless larger doses per fraction than 1 Gy are used, and especially if components of very rapid repair are present with half-times of less than about 0.5 hours. However, local and transient dose rates close to stepping sources can be up to several Gy per minute. Methods: Calculations were done assuming the linear quadratic formula for radiation damage, in which only the dose-squared term is subject to repair, at a constant exponential rate. The formula developed by Dale for fractionated low-dose-rate radiotherapy was used. A constant overall time of 140 hours and constant total dose of 70 Gy were assumed throughout, the continuous low dose-rate of 0.5 Gy/h (CLDR) providing the unitary standard effects for each PDR condition. Effects of dose-rates ranging from 4 Gy/h to 120 Gy/h (HDR at 2 Gy/min) were studied, and T (1(2)) from 4 minutes to 1.5 hours. Results: Curves are presented relating the ratio of increased biological effect (proportional to log cell kill) calculated for PDR relative to CLDR. Ratios as high as 1.5 can be found for large doses per pulse (> 1 Gy) at high instantaneous dose-rates if T (1(2)) in tissues is as short as a few minutes. The major influences on effect are dose per pulse, half-time of repair in the tissue, and - when T (1(2)) is short - the instantaneous dose-rate. Maximum ratios of PDR/CLDR effect occur when the dose-rate is such that pulse duration is approximately equal to T (1(2)) of repair. Results are presented for late-responding tissues, the differences from CLDR

  9. Fluence to Effective Dose and Effective Dose Equivalent Conversion Coefficients for Photons from 50 KeV to 10 GeV

    International Nuclear Information System (INIS)

    Ferrari, A.; Pelliccioni, M.; Pillon, M.

    1996-07-01

    Effective dose equivalent and effective dose per unit photon fluence have been calculated by the FLUKA code for various geometrical conditions of irradiation of an anthropomorphic phantom placed in a vacuum. Calculations have been performed for monoenergetic photons of energy ranging from 50 keV to 10 GeV. The agreement with the results of other authors, when existing, is generally very satisfactory

  10. Chest X ray effective doses estimation in computed radiography

    International Nuclear Information System (INIS)

    Abdalla, Esra Abdalrhman Dfaalla

    2013-06-01

    Conventional chest radiography is technically difficult because of wide in tissue attenuations in the chest and limitations of screen-film systems. Computed radiography (CR) offers a different approach utilizing a photostimulable phosphor. photostimulable phosphors overcome some image quality limitations of chest imaging. The objective of this study was to estimate the effective dose in computed radiography at three hospitals in Khartoum. This study has been conducted in radiography departments in three centres Advanced Diagnostic Center, Nilain Diagnostic Center, Modern Diagnostic Center. The entrance surface dose (ESD) measurement was conducted for quality control of x-ray machines and survey of operators experimental techniques. The ESDs were measured by UNFORS dosimeter and mathematical equations to estimate patient doses during chest X rays. A total of 120 patients were examined in three centres, among them 62 were males and 58 were females. The overall mean and range of patient dosed was 0.073±0.037 (0.014-0.16) mGy per procedure while the effective dose was 3.4±01.7 (0.6-7.0) mSv per procedure. This study compared radiation doses to patients radiographic examinations of chest using computed radiology. The radiation dose was measured in three centres in Khartoum- Sudan. The results of the measured effective dose showed that the dose in chest radiography was lower in computed radiography compared to previous studies.(Author)

  11. Collective radiation doses following a hypothetical, very severe accident to an irradiated fuel transport flask containing AGR fuel

    International Nuclear Information System (INIS)

    Corbett, J.O.

    1985-05-01

    Studies of the consequences of very severe, although unlikely, accidents to irradiated fuel transport flasks are made in order to evaluate risks. If an irradiated fuel transport flask carrying AGR fuel were damaged in a hypothetical accident involving a severe impact followed by a prolonged fire, a small proportion of caesium and other fission products might be released to the atmosphere from the gap inventory of broken fuel pins. The consequent radiation dose to the public would arise predominantly by direct irradiation from ground deposits and the ingestion of slightly contaminated foodstuffs. Although these collective doses must generally be estimated with the aid of computer codes, it is shown here that the worst case, when a high proportion of the radioactivity is deposited in a densely population area, can be assessed approximately by a much simpler method, an approach which is of great value in explaining the calculation in a manner that can be readily understood. A comparison is made between the simple approach and equivalent results from the NECTAR code, the worst case is compared with an ensemble average over all weather conditions, and the relative contributions of the two main routes to collective dose are discussed. (author)

  12. Review of time-dose effects in radiation therapy

    International Nuclear Information System (INIS)

    Peschel, R.E.; Fischer, J.J.

    1980-01-01

    A historical review of conventional fractionation offers little confidence that such treatment is optimal for all tumors. Thus manipulation of time-dose schedules may provide a relatively inexpensive yet potentially useful technique for improving therapeutic results in radiation therapy. Consideration of basic radiobiological principles and animal model data illustrates the complex and heterogeneous nature of normal tissue and tumor response to time-dose effects and supports the hypothesis that better time-dose prescriptions can be found in clinical practice. The number of possible time-dose prescriptions is very large, and a review of the clinical trials using nonconventional fractionation demonstrates that the sampled portion of the total three-dimensional space of time, fraction number, and dose has been very small. Only carefully designed clinical trials can establish the therapeutic advantage of a new treatment schedule, and methods for selecting the most promising schedules are discussed. The use of simple data reduction formulas for time-dose effects should be discarded since they ignore the very complexity and heterogeneity of tissues and tumors which may form the basis of improved clinical results

  13. Doses to patients from diagnostic radiology in Romania

    International Nuclear Information System (INIS)

    Iacob, O.; Diaconescu, C.

    2001-01-01

    Effective doses to over 2400 patients undergoing 20 of the most important types of X-ray examinations have been estimated from entrance surface doses or dose-area products, measured in 27 X-ray departments, and the appropriate conversion coefficients calculated by the NRPB for six mathematical phantoms representing 0, 1, 5, 10, 15 year old children and the adult. The patient-weighted mean effective dose from X-ray examinations performed annually in Romania is 1.32 mSv, with 1.40 mSv for the average adult patient and 0,59 mSv for the average paediatric patient. The corresponding annual collective effective dose is about 13,430 man Sv, with the main contribution belonging to adult patients (95%), the remainder of 5 percent - to paediatric patients. (author)

  14. Effect of low dose radiation on apoptosis in mouse spleen

    International Nuclear Information System (INIS)

    Chen Dong; Liu Jiamei; Chen Aijun; Liu Shuzheng

    1999-01-01

    Objective: To study the effect of whole body irradiation (WBI) with different doses of X-ray on apoptosis in mouse spleen. Methods: Time course changes and dose-effect relationship of apoptosis in mouse spleen induced by WBI were observed with transmission electron microscopy (TEM) qualitatively and TUNEL method semi-quantitatively. Results: Many typical apoptotic lymphocytes were found by TEM in mouse spleen after WBI with 2 Gy. No marked alterations of ultrastructure were found following WBI with 0.075 Gy. It was observed by TUNEL that the apoptosis of splenocytes increased after high dose radiation and decreased following low dose radiation (LDR). The dose-effect relationship of radiation-induced apoptosis showed a J-shaped curve. Conclusion: The effect of different doses of ionizing radiation on apoptosis in mouse spleen was distinct. And the decrease of apoptosis after LDR is considered a manifestation of radiation hormesis

  15. Evaluation of the effective dose and image quality of low-dose multi-detector CT for orthodontic treatment planning

    International Nuclear Information System (INIS)

    Chung, Gi Chung; Han, Won Jeong; Kim, Eun Kyung

    2010-01-01

    This study was designed to compare the effective doses from low-dose and standard-dose multi-detector CT (MDCT) scanning protocols and evaluate the image quality and the spatial resolution of the low-dose MDCT protocols for clinical use. 6-channel MDCT scanner (Siemens Medical System, Forschheim, Germany), was used for this study. Protocol of the standard-dose MDCT for the orthodontic analysis was 130 kV, 35 mAs, 1.25 mm slice width, 0.8 pitch. Those of the low-dose MDCT for orthodontic analysis and orthodontic surgery were 110 kV, 30 mAs, 1.25 mm slice width, 0.85 pitch and 110 kV, 45 mAs, 2.5 mm slice width, 0.85 pitch. Thermoluminescent dosimeters (TLDs) were placed at 31 sites throughout the levels of adult female ART head and neck phantom. Effective doses were calculated according to ICRP 1990 and 2007 recommendations. A formalin-fixed cadaver and AAPM CT performance phantom were scanned for the evaluation of subjective image quality and spatial resolution. Effective doses in μSv (E2007) were 699.1, 429.4 and 603.1 for standard-dose CT of orthodontic treatment, low-dose CT of orthodontic analysis, and low-dose CT of orthodontic surgery, respectively. The image quality from the low-dose protocol were not worse than those from the standard-dose protocol. The spatial resolutions of both standard-dose and low-dose CT images were acceptable. From the above results, it can be concluded that the low-dose MDCT protocol is preferable in obtaining CT images for orthodontic analysis and orthodontic surgery.

  16. Evaluation of the effective dose and image quality of low-dose multi-detector CT for orthodontic treatment planning

    Energy Technology Data Exchange (ETDEWEB)

    Chung, Gi Chung; Han, Won Jeong; Kim, Eun Kyung [Department of Oral and Maxillofacial Radiology, School of Dentistry, Dankook University, Cheonan (Korea, Republic of)

    2010-03-15

    This study was designed to compare the effective doses from low-dose and standard-dose multi-detector CT (MDCT) scanning protocols and evaluate the image quality and the spatial resolution of the low-dose MDCT protocols for clinical use. 6-channel MDCT scanner (Siemens Medical System, Forschheim, Germany), was used for this study. Protocol of the standard-dose MDCT for the orthodontic analysis was 130 kV, 35 mAs, 1.25 mm slice width, 0.8 pitch. Those of the low-dose MDCT for orthodontic analysis and orthodontic surgery were 110 kV, 30 mAs, 1.25 mm slice width, 0.85 pitch and 110 kV, 45 mAs, 2.5 mm slice width, 0.85 pitch. Thermoluminescent dosimeters (TLDs) were placed at 31 sites throughout the levels of adult female ART head and neck phantom. Effective doses were calculated according to ICRP 1990 and 2007 recommendations. A formalin-fixed cadaver and AAPM CT performance phantom were scanned for the evaluation of subjective image quality and spatial resolution. Effective doses in {mu}Sv (E2007) were 699.1, 429.4 and 603.1 for standard-dose CT of orthodontic treatment, low-dose CT of orthodontic analysis, and low-dose CT of orthodontic surgery, respectively. The image quality from the low-dose protocol were not worse than those from the standard-dose protocol. The spatial resolutions of both standard-dose and low-dose CT images were acceptable. From the above results, it can be concluded that the low-dose MDCT protocol is preferable in obtaining CT images for orthodontic analysis and orthodontic surgery.

  17. Medical effects of low doses of ionising radiation

    International Nuclear Information System (INIS)

    Coggle, J.E.

    1990-01-01

    Ionising radiation is genotoxic and causes biological effects via a chain of events involving DNA strand breaks and 'multiply damaged sites' as critical lesions that lead to cell death. The acute health effects of radiation after doses of a few gray, are due to such cell death and consequent disturbance of cell population kinetics. Because of cellular repair and repopulation there is generally a threshold dose of about 1-2 Gy below which such severe effects are not inducible. However, more subtle, sub-lethal mutational DNA damage in somatic cells of the body and the germ cells of the ovary and testis cause the two major low dose health risks -cancer induction and genetic (heritable) effects. This paper discusses some of the epidemiological and experimental evidence regarding radiation genetic effects, carcinogenesis and CNS teratogenesis. It concludes that current risk estimates imply that about 3% of all cancers; 1% of genetic disorders and between 0% and 0.3% of severe mental subnormality in the UK is attributable to the ubiquitous background radiation. The health risks associated with the medical uses of radiation are smaller, whilst the nuclear industry causes perhaps 1% of the health detriment attributable to background doses. (author)

  18. Identification of dose-reduction techniques for BWR and PWR repetitive high-dose jobs

    International Nuclear Information System (INIS)

    Dionne, B.J.; Baum, J.W.

    1984-01-01

    As a result of concern about the apparent increase in collective radiation dose to workers at nuclear power plants, this project will provide information to industry in preplanning for radiation protection during maintenance operations. This study identifies Boiling Water Reactor (BWR) and Pressurized Water Reactor (PWR) repetitive jobs, and respective collective dose trends and dose reduction techniques. 3 references, 2 tables

  19. Impedance and Collective Effects

    CERN Document Server

    Metral, E; Rumolo, R; Herr, W

    2013-01-01

    This document is part of Subvolume C 'Accelerators and Colliders' of Volume 21 'Elementary Particles' of Landolt-Börnstein - Group I 'Elementary Particles, Nuclei and Atoms'. It contains the Chapter '4 Impedance and Collective Effects' with the content: 4 Impedance and Collective Effects Introduction 4.1 Space Charge 4.2 Wake Fields and Impedances 4.3 Coherent Instabilities 4.4 Landau Damping 4.5 Two-Stream Effects (Electron Cloud and Ions) 4.6 Beam-Beam Effects 4.7 Numerical Modelling

  20. Radiation doses from radioactivity in incandescent mantles

    International Nuclear Information System (INIS)

    1985-01-01

    Thorium nitrate is used in the production of incandescent mantles for gas lanterns. In this report dose estimates are given for internal and external exposure that result from the use of the incandescent mantles for gas lanterns. The collective, effective dose equivalent for all users of gas mantles is estimated to be about 100 Sv per annum in the Netherlands. For the population involved (ca. 700,000 persons) this is roughly equivalent to 5% to 10% of the collective dose equivalent associated with exposure to radiation from natural sources. The major contribution to dose estimates comes from inhalation of radium during burning of the mantles. A pessimistic approach results in individual dose estimates for inhalation of up to 0.2 mSv. Consideration of dose consequences in case of a fire in a storage department learns that it is necessary for emergency personnel to wear respirators. It is concluded that the uncontrolled removal of used gas mantles to the environment (soil) does not result in a significant contribution to environmental radiation exposure. (Auth.)

  1. Effects of low doses of ionizing radiation

    International Nuclear Information System (INIS)

    Masse, R.

    2006-01-01

    Several groups of human have been irradiated by accidental or medical exposure, if no gene defect has been associated to these exposures, some radioinduced cancers interesting several organs are observed among persons exposed over 100 to 200 mSv delivered at high dose rate. Numerous steps are now identified between the initial energy deposit in tissue and the aberrations of cell that lead to tumors but the sequence of events and the specific character of some of them are the subject of controversy. The stake of this controversy is the risk assessment. From the hypothesis called linear relationship without threshold is developed an approach that leads to predict cancers at any tiny dose without real scientific foundation. The nature and the intensity of biological effects depend on the quantity of energy absorbed in tissue and the modality of its distribution in space and time. The probability to reach a target (a gene) associated to the cancerating of tissue is directly proportional to the dose without any other threshold than the quantity of energy necessary to the effect, its probability of effect can be a more complex function and depends on the quality of the damage produced as well as the ability of the cell to repair the damage. These two parameters are influenced by the concentration of initial injuries in the target so by the quality of radiation and by the dose rate. The mechanisms of defence explain the low efficiency of radiation as carcinogen and then the linearity of effects in the area of low doses is certainly the least defensible scientific hypothesis for the prediction of the risks. (N.C.)

  2. Dose reconstruction in deforming lung anatomy: Dose grid size effects and clinical implications

    International Nuclear Information System (INIS)

    Rosu, Mihaela; Chetty, Indrin J.; Balter, James M.; Kessler, Marc L.; McShan, Daniel L.; Ten Haken, Randall K.

    2005-01-01

    In this study we investigated the accumulation of dose to a deforming anatomy (such as lung) based on voxel tracking and by using time weighting factors derived from a breathing probability distribution function (p.d.f.). A mutual information registration scheme (using thin-plate spline warping) provided a transformation that allows the tracking of points between exhale and inhale treatment planning datasets (and/or intermediate state scans). The dose distributions were computed at the same resolution on each dataset using the Dose Planning Method (DPM) Monte Carlo code. Two accumulation/interpolation approaches were assessed. The first maps exhale dose grid points onto the inhale scan, estimates the doses at the 'tracked' locations by trilinear interpolation and scores the accumulated doses (via the p.d.f.) on the original exhale data set. In the second approach, the 'volume' associated with each exhale dose grid point (exhale dose voxel) is first subdivided into octants, the center of each octant is mapped to locations on the inhale dose grid and doses are estimated by trilinear interpolation. The octant doses are then averaged to form the inhale voxel dose and scored at the original exhale dose grid point location. Differences between the interpolation schemes are voxel size and tissue density dependent, but in general appear primarily only in regions with steep dose gradients (e.g., penumbra). Their magnitude (small regions of few percent differences) is less than the alterations in dose due to positional and shape changes from breathing in the first place. Thus, for sufficiently small dose grid point spacing, and relative to organ motion and deformation, differences due solely to the interpolation are unlikely to result in clinically significant differences to volume-based evaluation metrics such as mean lung dose (MLD) and tumor equivalent uniform dose (gEUD). The overall effects of deformation vary among patients. They depend on the tumor location, field

  3. Radiation effects of high and low doses

    International Nuclear Information System (INIS)

    El-Naggar, A.M.

    1998-01-01

    The extensive proliferation of the uses and applications of atomic and nuclear energy resulted in possible repercussions on human health. The prominent features of the health hazards that may be incurred after exposure to high and low radiation doses are discussed. The physical and biological factors involved in the sequential development of radiation health effects and the different cellular responses to radiation injury are considered. The main criteria and features of radiation effects of high and low doses are comprehensively outlined

  4. [Optimizing staff radiation protection in radiology by minimizing the effective dose].

    Science.gov (United States)

    von Boetticher, H; Lachmund, J; Hoffmann, W; Luska, G

    2006-03-01

    In the present study the optimization of radiation protection devices is achieved by minimizing the effective dose of the staff members since the stochastic radiation effects correlate to the effective dose. Radiation exposure dosimetry was performed with TLD measurements using one Alderson Phantom in the patient position and a second phantom in the typical position of the personnel. Various types of protective clothing as well as fixed shields were considered in the calculations. It was shown that the doses of the unshielded organs (thyroid, parts of the active bone marrow) contribute significantly to the effective dose of the staff. Therefore, there is no linear relationship between the shielding factors for protective garments and the effective dose. An additional thyroid protection collar reduces the effective dose by a factor of 1.7 - 3.0. X-ray protective clothing with a 0.35 mm lead equivalent and an additional thyroid protection collar provides better protection against radiation than an apron with a 0.5 mm lead equivalent but no collar. The use of thyroid protection collars is an effective preventive measure against exceeding occupational organ dose limits, and a thyroid shield also considerably reduces the effective dose. Therefore, thyroid protection collars should be a required component of anti-X protection.

  5. Effects of dose, species, and dosing vehicle on the disposition of methacrylonitrile (MAN) in male rats

    International Nuclear Information System (INIS)

    Sanchez, I.M.; Ghanayem, B.I.

    1991-01-01

    MAN is structurally similar to known carcinogen acrylontrile (AN), with nitriles having similar industrial uses. Current studies were designed to investigate the biological fate of 2- 14 C-MAN in rats. After gavage administration of 115, 11.5 or 1.15 mg MAN/kg in water, F344 male rats were placed in glass metabolism cages and urine, expired air and feces were collected. Rats were sacrificed at various times and concentration of MAN-derived radioactivity in tissues was determined. MAN was rapidly absorbed from the GI tract and distributed to all major tissues. Sixty-70% of the low and medium doses were exhaled as 14 CO 2 in 72 hr compared to 25% of the highest dose. While 40% of the highest dose was expired as organic volatiles in 72 hr, only 9-12% of the low and accounted for 20-30% of all doses within 72 hr after dosing. Comparison of MAN disposition in Sprague-Dawley (SD) and F344 rats at 115 mg/kg revealed that SD rats excreted a greater % of the dose as 14 CO 2 and in the urine than did F344 rats. Administration of 115 mg MAN/kg to SD male rats in safflower oil resulted in increased elimination of MAN-derived radioactivity as CO 2 , volatiles, and in the urine over that observed when administered in water. These results suggest that: (1) saturation of MAN metabolism occurs at high doses: (2) MAN metabolism and disposition differ with the strain of rats studied; (3) MAN disposition may vary with the dosing vehicle used; and (4) MAN metabolism and disposition is apparently different from that reported on AN

  6. Dose-rate effects of low-dropout voltage regulator at various biases

    International Nuclear Information System (INIS)

    Wang Yiyuan; Zheng Yuzhan; Gao Bo; Chen Rui; Fei Wuxiong; Lu Wu; Ren Diyuan

    2010-01-01

    A low-dropout voltage regulator, LM2941, was irradiated by 60 Co γ-rays at various dose rates and biases for investigating the total dose and dose rate effects. The radiation responses show that the key electrical parameters, including its output and dropout voltage, and the maximum output current, are sensitive to total dose and dose rates, and are significantly degraded at low dose rate and zero bias. The integrated circuits damage change with the dose rates and biases, and the dose-rate effects are relative to its electric field. (authors)

  7. Collective dose estimation in Portuguese population due to medical exams of diagnostic radiology and nuclear medicine

    International Nuclear Information System (INIS)

    Teles, Pedro; Vaz, Pedro; Paulo, Graciano; Santos, Joana; Pascoal, Ana; Lanca, Isabel; Matela, Nuno; Sousa, Patrick; Carvoeiras, Pedro; Parafita, Rui; Simaozinho, Paula

    2013-01-01

    In order to assess the exposure of the Portuguese population to ionizing radiation due to medical examinations of diagnostic radiology and nuclear medicine, a working group, consisting of 40 institutions, public and private, was created to evaluation the coletive dose in the Portuguese population in 2010. This work was conducted in collaboration with the Dose Datamed European consortium, which aims to assess the exposure of the European population to ionizing radiation due to 20 diagnostic radiology examinations most frequent in Europe (the 'TOP 20') and nuclear medicine examinations. We obtained an average value of collective dose of ≈ 1 mSv/caput, which puts Portugal in the category of countries medium to high exposure to Europe. We hope that this work can be a starting point to bridge the persistent lack of studies in the areas referred to in Portugal, and to enable the characterization periodic exposure of the Portuguese population to ionizing radiation in the context of medical applications

  8. Radiation doses and correlated late effects in diagnostic radiology

    International Nuclear Information System (INIS)

    Gustafsson, M.

    1980-04-01

    Patient irradiation in diagnostic radiology was estimated from measurements of absorbed doses in different organs, assessment of the energy imparted and retrospective calculations based on literature data. Possible late biological effects, with special aspects on children, were surveyed. The dose to the lens of the eye and the possibility of shielding in carotid angiography was studied as was the absorbed dose to the thyroid gland at cardiac catheterization and angiocardiography in children. Calculations of the mean bone marrow dose and gonad doses were performed in children with chronic skeletal disease revealing large contributions from examinations of organs other than the skeleton. The dose distribution in the breast in mammography was investigated. Comparison of the energy imparted in common roentgen examinations in 1960 and 1975 showed an unexpected low decrease in spite of technical improvements. Reasons for the failing decrease are discussed. The energy imparted to children in urological examinations was reduced significantly due to introduction of high sensitivity screens and omission of dose demanding projections. Contributions to the possible late effects were estimated on the basis of the organ doses assessed. (author)

  9. Effective doses to family members of patients treated with radioiodine-131

    International Nuclear Information System (INIS)

    Kocovska, M Zdraveska; Vaskova, O; Majstorov, V; Kuzmanovska, S; Gjorceva, D Pop; Jokic, V Spasic

    2011-01-01

    The purpose of this study was to evaluate the effective dose to family members of thyroid cancer and hyperthyroid patients treated with radioiodine-131, and also to compare the results with dose constraints proposed by the International Commission of Radiological Protection (ICRP) and the Basic Safety Standards (BSS) of the International Atomic Energy Agency (IAEA). For the estimation of the effective doses, sixty family members of sixty patients, treated with radioiodine-131, and thermoluminiscent dosimeters (Model TLD 100) were used. Thyroid cancer patients were hospitalized for three days, while hyperthyroid patients were treated on out-patient basis. The family members wore TLD in front of the torso for seven days. The radiation doses to family members of thyroid cancer patients were well below the recommended dose constraint of 1 mSv. The mean value of effective dose was 0.21 mSv (min 0.02 - max 0.51 mSv). Effective doses, higher than 1 mSv, were detected for 11 family members of hyperthyroid patients. The mean value of effective dose of family members of hyperthyroid patients was 0.87 mSv (min 0.12 - max 6.79). The estimated effective doses to family members of hyperthyroid patients were higher than the effective doses to family members of thyroid carcinoma patients. These findings may be considered when establishing new national guidelines concerning radiation protection and release of patients after a treatment with radioiodine therapy.

  10. Occupational radiation dose in Indonesia 1981-1986

    International Nuclear Information System (INIS)

    Hiswara, E.; Ismono, A.

    1993-01-01

    Occupational radiation dose in Indonesia 1981-1986. This paper presents the occupational radiation dose in Indonesia during the period of 1981-1986. The highest collective dose accurated in 1983 was calculated to be 2.68 man-Sv, with the maximum mean dose per worker, who received dose more than zero, was around 11.07 mSv in the same year. In 1985, a relative collective dose from medical occupations of 1.88 man mSv for 10 6 population was estimated based on its total collective dose of 0.31 man-mSv. The total number of workers who received annual collective dose less than 5 mSv varied from 97.0% in 1981 to 99.5% in 1986. As a group, the industrial occupations has considerably higher risk in receiving a dose than others. (authors). 11 refs., 7 tabs

  11. Dose rate-dependent marrow toxicity of TBI in dogs and marrow sparing effect at high dose rate by dose fractionation.

    Science.gov (United States)

    Storb, R; Raff, R F; Graham, T; Appelbaum, F R; Deeg, H J; Schuening, F G; Sale, G; Seidel, K

    1999-01-01

    We evaluated the marrow toxicity of 200 and 300 cGy total-body irradiation (TBI) delivered at 10 and 60 cGy/min, respectively, in dogs not rescued by marrow transplant. Additionally, we compared toxicities after 300 cGy fractionated TBI (100 cGy fractions) to that after single-dose TBI at 10 and 60 cGy/min. Marrow toxicities were assessed on the basis of peripheral blood cell count changes and mortality from radiation-induced pancytopenia. TBI doses studied were just below the dose at which all dogs die despite optimal support. Specifically, 18 dogs were given single doses of 200 cGy TBI, delivered at either 10 (n=13) or 60 (n=5) cGy/min. Thirty-one dogs received 300 cGy TBI at 10 cGy/min, delivered as either single doses (n=21) or three fractions of 100 cGy each (n=10). Seventeen dogs were given 300 cGy TBI at 60 cGy/min, administered either as single doses (n=5) or three fractions of 100 cGy each (n=10). Within the limitations of the experimental design, three conclusions were drawn: 1) with 200 and 300 cGy single-dose TBI, an increase of dose rate from 10 to 60 cGy/min, respectively, caused significant increases in marrow toxicity; 2) at 60 cGy/min, dose fractionation resulted in a significant decrease in marrow toxicities, whereas such a protective effect was not seen at 10 cGy/min; and 3) with fractionated TBI, no significant differences in marrow toxicity were seen between dogs irradiated at 60 and 10 cGy/min. The reduced effectiveness of TBI when a dose of 300 cGy was divided into three fractions of 100 cGy or when dose rate was reduced from 60 cGy/min to 10 cGy/min was consistent with models of radiation toxicity that allow for repair of sublethal injury in DNA.

  12. Late effects of various dose-fractionation regimens

    International Nuclear Information System (INIS)

    Turesson, I.; Notter, G.

    1983-01-01

    These clinical investigations of various dose-fractionation regimens on human skin show that: The late reactions cannot be predicted from the early reactions; The dose-response curves for late reactions are much steeper than for early reactions; Equivalent doses for various fractionation schedules concerning late effects can be calculated by means of a corrected CRE (NSD) formula; the correction must be considered preliminary because further follow-up is needed. A clinical fractionation study of this type requires: Extremely careful dosimetry; Study of the same anatomical region; Very long follow-up; Studies at different effect levels; Skin reaction is the only end point we have studied systematically for different fractionation regimens. Experience with the CRE formula as a model for calculating isoeffect doses for different fractionation schedules in routine clinical use can be summarized as follows: The CRE formula has been used prospectively since 1972 in all patients; CRE-equivalent weekly doses to 5 x 2.0 Gy per week has been used. (Although the fractionation schedule is changed, the overall treatment time is still the same); The CRE range was 18 to 21 for curative radiotherapy on carcinomas; No irradiation was applied during pronounced acute reactions. No unexpected complications have been observed under these conditions

  13. Dose dependence on stochastic radiobiological effect in radiation risk estimation

    International Nuclear Information System (INIS)

    Komochkov, M.M.

    1999-01-01

    The analysis of the results in dose -- effect relationship observation has been carried out on the cell and organism levels, with the aim to obtain more precise data on the risk coefficients at low doses. The results are represented by two contrasting groups of dose dependence on effect: a downwards concave and a J-shaped curve. Both types of dependence are described by the equation solutions of an assumed unified protective mechanism, which comprises two components: constitutive and adaptive or inducible ones. The latest data analysis of the downwards concave dependence curves shows a considerable underestimation of radiation risk in all types of cancer, except leukemia, for a number of critical groups in a population, at low doses comparing to the ICRP recommendations. With the dose increase, the decrease of the effect value per dose unit is observed. It may be possibly related to the switching of the activity of the adaptive protective mechanism, with some threshold dose values being exceeded

  14. Estimation of effective dose during hysterosalpingography procedures

    International Nuclear Information System (INIS)

    Alzimamil, K.; Babikir, E.; Alkhorayef, M.; Sulieman, A.; Alsafi, K.; Omer, H.

    2014-08-01

    Hysterosalpingography (HSG) is the most frequently used diagnostic tool to evaluate the endometrial cavity and fallopian tube by using conventional x-ray or fluoroscopy. Determination of the patient radiation doses values from x-ray examinations provides useful guidance on where best to concentrate efforts on patient dose reduction in order to optimize the protection of the patients. The aims of this study were to measure the patients entrance surface air kerma doses (ESA K), effective doses and to compare practices between different hospitals in Sudan. ESA K were measured for patient using calibrated thermo luminance dosimeters (TLDs, Gr-200A). Effective doses were estimated using National Radiological Protection Board (NRPB) software. This study was conducted in five radiological departments: Two Teaching Hospitals (A and D), two private hospitals (B and C) and one University Hospital (E). The mean ESD was 20.1 mGy, 28.9 mGy, 13.6 mGy, 58.65 mGy, 35.7, 22.4 and 19.6 mGy for hospitals A,B,C,D, and E), respectively. The mean effective dose was 2.4 mSv, 3.5 mSv, 1.6 mSv, 7.1 mSv and 4.3 mSv in the same order. The study showed wide variations in the ESDs with three of the hospitals having values above the internationally reported values. Number of x-ray images, fluoroscopy time, operator skills x-ray machine type and clinical complexity of the procedures were shown to be major contributors to the variations reported. Results demonstrated the need for standardization of technique throughout the hospital. The results also suggest that there is a need to optimize the procedures. Local DRLs were proposed for the entire procedures. (author)

  15. Alternate day treatment and late effects: The concept of an effective dose per fraction

    International Nuclear Information System (INIS)

    Courdi, A.; Hery, M.; Gabillat, J.M.

    1990-01-01

    Although most institutions treat all fields each day, some radiotherapists continue to adopt an alternate day schedule. The resulting daily variations of the dose per fraction in laterally located targets have been analyzed using the linear-quadratic model. Patients with breast carcinoma treated with definitive radiotherapy in 1974-1975 with one field a day were studied. An effective dose per fraction was derived, with a value higher than the average dose per fraction received by the reference point. The greater the fluctuations between the doses per fraction on successive days, the higher the effective dose per fraction. The corresponding cell survival due to alternate treatment as compared to survival with daily treatment depends on the alpha/beta ratio. For a late effect with low alpha/beta ratio, an alternate treatment may lead to almost 10-fold increase in cell kill in these lateral targets such as those responsible for subcutaneous sclerosis as compared to daily treatment of all fields with the same total dose. Taking the average effective dose per fraction in our series, the increase in cell kill was 4-fold. Acute effects would suffer less damage due to alternate treatment because of a high alpha/beta ratio. Treatment on an alternate schedule should be restricted to palliative radiotherapy

  16. Automated size-specific CT dose monitoring program: Assessing variability in CT dose

    International Nuclear Information System (INIS)

    Christianson, Olav; Li Xiang; Frush, Donald; Samei, Ehsan

    2012-01-01

    Purpose: The potential health risks associated with low levels of ionizing radiation have created a movement in the radiology community to optimize computed tomography (CT) imaging protocols to use the lowest radiation dose possible without compromising the diagnostic usefulness of the images. Despite efforts to use appropriate and consistent radiation doses, studies suggest that a great deal of variability in radiation dose exists both within and between institutions for CT imaging. In this context, the authors have developed an automated size-specific radiation dose monitoring program for CT and used this program to assess variability in size-adjusted effective dose from CT imaging. Methods: The authors radiation dose monitoring program operates on an independent health insurance portability and accountability act compliant dosimetry server. Digital imaging and communication in medicine routing software is used to isolate dose report screen captures and scout images for all incoming CT studies. Effective dose conversion factors (k-factors) are determined based on the protocol and optical character recognition is used to extract the CT dose index and dose-length product. The patient's thickness is obtained by applying an adaptive thresholding algorithm to the scout images and is used to calculate the size-adjusted effective dose (ED adj ). The radiation dose monitoring program was used to collect data on 6351 CT studies from three scanner models (GE Lightspeed Pro 16, GE Lightspeed VCT, and GE Definition CT750 HD) and two institutions over a one-month period and to analyze the variability in ED adj between scanner models and across institutions. Results: No significant difference was found between computer measurements of patient thickness and observer measurements (p= 0.17), and the average difference between the two methods was less than 4%. Applying the size correction resulted in ED adj that differed by up to 44% from effective dose estimates that were not

  17. Trends of the effective dose distribution of occupational exposures in medical and research departments for KIRAMS in Republic of Korea

    International Nuclear Information System (INIS)

    Park, M.; Kim, G. S.; Ji, Y. H.; Jung, M. S.; Kim, K. B.; Jung, H.

    2014-01-01

    This work proposes the basic reference data of occupational dose management and statistical dose distribution with the classification of radiation work groups though analysis of occupational dose distribution. Data on occupational radiation exposure from medical and scientific usage of radiation in Korea Institute of Radiological and Medical Sciences for the years 2002-11 are presented and evaluated with the characteristic tendency of radiation working groups. The results of occupational radiation exposure were measured by personal dosemeters. The monitored occupational exposure dose data were evaluated according to the average effective dose and collective dose. The most annual average effective dose for all occupational radiation workers was under 1 mSv. Considering the dose distribution of each department, most overexposure workers worked in radiopharmaceutical product facilities, nuclear medicine department and radiation oncology department. In addition, no monitored workers were found to have received an occupational exposure over 50 mSv in single year or 100 mSv in this period. Although the trend of occupational exposure was controlled <1 mSv after 2007 and the radiation protection status was sufficient, it was consistently necessary to optimise and reduce the occupational radiation exposure. (authors)

  18. Effective doses to family members of patients treated with radioiodine 131

    International Nuclear Information System (INIS)

    Kocovska, Marina Zdravevska; Ristevska, Svetlana Micevska; Nikolovski, Sasho; Jokic, Vesna Spasic

    2010-01-01

    The purpose of this study was to evaluate the effective dose to family members of thyroid cancer and hyperthyroid patients treated with radioiodine 131; also to compare the results with dose constraints proposed by International Commission of Radiological Protection (ICRP) and Basic Safety Standards (BSS) of the International Atomic Energy Agency (IAEA). Material and methods: for estimation of effective doses at sixty family members of thirty thyroid cancer and thirty hyperthyroid patients treated with radioiodine 131, the thermoluminescent dosimeters, Model TLD 100, were used. Thyroid cancer patients were hospitalized for three days, while hyperthyroid patients were treated on out-patient basis. The family members wore thermoluminescent dosimeter in front of the torso for seven days. Results: The radiation doses to family members of thyroid cancer patients were well below recommended dose constraint of 1 mSv. The mean value of effective dose was 0.21 mSv (min 0.02 - max 0.51 mSv). Effective doses, higher than 1 mSv, were detected at 11 family members of hyperthyroid patients.. The mean value of effective dose at family members of hyperthyroid patients was 0.87 mSv (min 0.12 - max 6.79) Conclusion: After three days of hospitalization and detailed given oral and written instruction, thyroid carcinoma patients maintain not to exceed the proposed dose limits. Hyperthyroid patients present a greater radiation hazard than thyroid carcinoma patients. The estimated effective doses were higher than the effective doses at family members of thyroid carcinoma patients. These findings may be considered when establishing new national guidelines concerning radiation protection and release of patients after a treatment with radioiodine therapy.(Author)

  19. The Effective Dose Due to Radionuclides Intake Via Ingestion in Poland in 1986-1999

    International Nuclear Information System (INIS)

    Grabowski, D.; Kurowski, W.; Muszynski, W.; Rubel, B.; Swietochowska, J.

    2001-01-01

    Full text: One of the pathways of radiation exposure in humans is consumption of contaminated food. The composition of an average diet is diversified for various groups within the population and depends on age, sex, consumption habit and performed work. To asses the dose obtained by people due to ingestion of contaminated food, the activity of main products of Polish diet has been analysed for period 1986 - 1999. The samples of milk, meat, vegetables, fruit and cereals were collected all over the territory of Poland to determine the activity of caesium isotopes. In the first two-year after the Chernobyl accident the differences in contamination were observed in various regions. Later on the differences were less pronounced except in milk and meat. The calculation of an average annual intake of caesium isotopes was based on statistical data consumption and contamination of certain product important in daily diet. Annual intake of caesium was different among regions. Mean annual effective dose related to the ingestion of contaminated food of 137 Cs was assessed on 54μSv in 1986 and 28μSv in 1987 and of 134 Cs on 34μSv and 13μSv respectively. In next years the dose was diminishing and from 1993 the average annual effective dose from 137 Cs has been on level 6-7 μSv. (author)

  20. Development of Real-Time Measurement of Effective Dose for High Dose Rate Neutron Fields

    CERN Document Server

    Braby, L A; Reece, W D

    2003-01-01

    Studies of the effects of low doses of ionizing radiation require sources of radiation which are well characterized in terms of the dose and the quality of the radiation. One of the best measures of the quality of neutron irradiation is the dose mean lineal energy. At very low dose rates this can be determined by measuring individual energy deposition events, and calculating the dose mean of the event size. However, at the dose rates that are normally required for biology experiments, the individual events can not be separated by radiation detectors. However, the total energy deposited in a specified time interval can be measured. This total energy has a random variation which depends on the size of the individual events, so the dose mean lineal energy can be calculated from the variance of repeated measurements of the energy deposited in a fixed time. We have developed a specialized charge integration circuit for the measurement of the charge produced in a small ion chamber in typical neutron irradiation exp...

  1. CARCINOGENIC EFFECTS OF LOW DOSES OF IONIZING RADIATION

    Science.gov (United States)

    Carcinogenic Effects of Low Doses of Ionizing RadiationR Julian Preston, Environmental Carcinogenesis Division, NHEERL, U.S. Environmental Protection Agency, Research Triangle Park, NC 27711The form of the dose-response curve for radiation-induced cancers, particu...

  2. Effects of low doses of ionizing radiation; Effets des faibles doses de rayonnements ionisants

    Energy Technology Data Exchange (ETDEWEB)

    Masse, R. [Office de Protection contre les Rayonnements Ionisants, 78 - le Vesinet (France)

    2006-07-01

    Several groups of human have been irradiated by accidental or medical exposure, if no gene defect has been associated to these exposures, some radioinduced cancers interesting several organs are observed among persons exposed over 100 to 200 mSv delivered at high dose rate. Numerous steps are now identified between the initial energy deposit in tissue and the aberrations of cell that lead to tumors but the sequence of events and the specific character of some of them are the subject of controversy. The stake of this controversy is the risk assessment. From the hypothesis called linear relationship without threshold is developed an approach that leads to predict cancers at any tiny dose without real scientific foundation. The nature and the intensity of biological effects depend on the quantity of energy absorbed in tissue and the modality of its distribution in space and time. The probability to reach a target (a gene) associated to the cancerating of tissue is directly proportional to the dose without any other threshold than the quantity of energy necessary to the effect, its probability of effect can be a more complex function and depends on the quality of the damage produced as well as the ability of the cell to repair the damage. These two parameters are influenced by the concentration of initial injuries in the target so by the quality of radiation and by the dose rate. The mechanisms of defence explain the low efficiency of radiation as carcinogen and then the linearity of effects in the area of low doses is certainly the least defensible scientific hypothesis for the prediction of the risks. (N.C.)

  3. Estimation of effective dose for children in interventional cardiology

    Directory of Open Access Journals (Sweden)

    S. S. Sarycheva

    2017-01-01

    Full Text Available This study is devoted to the estimation of effective dose for children undergoing interventional cardiology examinations. The conversion coefficients (CC from directly measured dose area product (DAP value to effective dose (ED were calculated within the approved effective dose assessment methodology (Guidelines 2.6.1. 2944-11. The CC, Ed K , [mSv / (Gy • cm2] for newborn infants and children of 1, 5, 10 and 15 years old (main(range were calculated as 2.5 (1.8-3.2; 1.1 (0.8-1.3; 0.6 (0.4-0.7; 0.4 (0.3-0.5; and 0,22 (0,18-0,30 respectively. A special Finnish computer program PCXMC 2.0 was used for calculating the dose CC. The series of calculations were made for different values of the physical and geometrical parameters based on their real-existing range of values. The value of CC from DAP to ED were calculated for all pediatric age groups. This work included 153 pediatric interventional studies carried out in two hospitals of the city of St. Petersburg for the period of one year from the summer of 2015. The dose CC dependency from the patient’s age and parameters of the examinations were under the study. The dependence from the beam quality (filtration and tube voltage and age of the patient were found. The younger is the patient, stronger is the filtration and higher is the voltage, the higher is the CC value. The CC in the younger (newborn and older (15 years age groups are different by the factor of 10. It was shown that the changes of the geometric parameters (in the scope of their real existing range have small effect on the value of the effective dose, not exceed 30-50% allowable for radiation protection purpose. The real values of effective doses of children undergoing cardiac interventions were estimated. In severe cases, the values of ED can reach several tens of mSv.

  4. Committed effective dose from thoron daughters inhalation

    International Nuclear Information System (INIS)

    Campos, M.P.; Pecequilo, B.R.S.

    2000-01-01

    Mankind's interest in natural radiation exposure levels has increased over the past fifty years and it is now recognized that the most significant contributors to human irradiation by natural sources are the short-lived decay products of radon ( 222 Rn) and thoron ( 220 Rn). Despite the thoron short half-life of 55 s, effective dose from inhalation of thoron an its progeny ( 212 Pb and 212 Bi) must be considered, owing to the high thorium background in countries like Brazil, China and India, for example. The indoor committed effective dose was assessed by air sampling at the thorium purification plant and the nuclear materials storage site of the Instituto de Pesquisas Energeticas e Nucleares; Sao Paulo, Brazil. A total of 21 glass fiber filter samples was analyzed by high resolution gamma ray spectrometry in order to obtain the 212 Pb and 212 Bi activities. The equilibrium equivalent concentration (EEC) varied from 0.3 Bq/m 3 to 6.8 Bq/m 3 for the storage site air samples and from 9.9 Bq/m 3 to 249.8 Bq/m 3 for the thorium purification plant air samples. As retention studies indicate a biological half-life of a few hours inhaled thoron progeny in the human lungs, the main fraction of the potential alpha energy (PAEC) deposited is absorbed in the lungs, meaning negligible to the effective dose the contribution of the dose in other times. The committed effective dose due thoron progeny was performed by compartimental analysis following the ICRP 66 lung compartimental model and ICRP 67 lead compartimental model. The values obtained varied from 0.03 mSv/a to 0.67 mSv/a for the storage site air samples and from 0.12 mSv/a to 6.00 mSv/a for the thorium purification plant air samples. (author)

  5. Additional effective dose equivalent for adults and children in Poland as the result of mushroom consumption

    International Nuclear Information System (INIS)

    Jasinska, H.; Kozak, K.; Mietelski, J.W.

    2004-01-01

    Experimental data of caesium radioactivity in samples of various mushrooms collected all over Poland from 1986 to 1989 are presented. Nearly 80 samples from Poland and a few samples from Austria and USSR were analysed. The effective dose equivalents for adults and children caused by the consumption of one mass unit of dried mushrooms for each sample were estimated. (author)

  6. Pediatric Obesity: Pharmacokinetic Alterations and Effects on Antimicrobial Dosing.

    Science.gov (United States)

    Natale, Stephanie; Bradley, John; Nguyen, William Huy; Tran, Tri; Ny, Pamela; La, Kirsten; Vivian, Eva; Le, Jennifer

    2017-03-01

    Limited data exist for appropriate drug dosing in obese children. This comprehensive review summarizes pharmacokinetic (PK) alterations that occur with age and obesity, and these effects on antimicrobial dosing. A thorough comparison of different measures of body weight and specific antimicrobial agents including cefazolin, cefepime, ceftazidime, daptomycin, doripenem, gentamicin, linezolid, meropenem, piperacillin-tazobactam, tobramycin, vancomycin, and voriconazole is presented. PubMed (1966-July 2015) and Cochrane Library searches were performed using these key terms: children, pharmacokinetic, obesity, overweight, body mass index, ideal body weight, lean body weight, body composition, and specific antimicrobial drugs. PK studies in obese children and, if necessary, data from adult studies were summarized. Knowledge of PK alterations stemming from physiologic changes that occur with age from the neonate to adolescent, as well as those that result from increased body fat, become an essential first step toward optimizing drug dosing in obese children. Excessive amounts of adipose tissue contribute significantly to body size, total body water content, and organ size and function that may modify drug distribution and clearance. PK studies that evaluated antimicrobial dosing primarily used total (or actual) body weight (TBW) for loading doses and TBW or adjusted body weight for maintenance doses, depending on the drugs' properties and dosing units. PK studies in obese children are imperative to elucidate drug distribution, clearance, and, consequently, the dose required for effective therapy in these children. Future studies should evaluate the effects of both age and obesity on drug dosing because the incidence of obesity is increasing in pediatric patients. © 2017 Pharmacotherapy Publications, Inc.

  7. Effective dose calculation in CT using high sensitivity TLDs

    International Nuclear Information System (INIS)

    Brady, Z.; Johnston, P.N.

    2010-01-01

    Full text: To determine the effective dose for common paediatric CT examinations using thermoluminescence dosimetry (TLD) mea surements. High sensitivity TLD chips (LiF:Mg,Cu,P, TLD-IOOH, Thermo Fisher Scientific, Waltham, MA) were calibrated on a linac at an energy of 6 MY. A calibration was also performed on a superricial X-ray unit at a kilovoltage energy to validate the megavoltage cali bration for the purpose of measuring doses in the diagnostic energy range. The dose variation across large organs was assessed and a methodology for TLD placement in a 10 year old anthropomorphic phantom developed. Effective dose was calculated from the TLD measured absorbed doses for typical CT examinations after correcting for the TLD energy response and taking into account differences in the mass energy absorption coefficients for different tissues and organs. Results Using new tissue weighting factors recommended in ICRP Publication 103, the effective dose for a CT brain examination on a 10 year old was 1.6 millisieverts (mSv), 4.9 mSv for a CT chest exa ination and 4.7 mSv for a CT abdomen/pelvis examination. These values are lower for the CT brain examination, higher for the CT chest examination and approximately the same for the CT abdomen/ pelvis examination when compared with effective doses calculated using ICRP Publication 60 tissue weighting factors. Conclusions High sensitivity TLDs calibrated with a radiotherapy linac are useful for measuring dose in the diagnostic energy range and overcome limitations of output reproducibility and uniformity asso ciated with traditional TLD calibration on CT scanners or beam quality matched diagnostic X-ray units.

  8. Carcinogenesis induced by low-dose radiation

    Directory of Open Access Journals (Sweden)

    Piotrowski Igor

    2017-11-01

    Full Text Available Although the effects of high dose radiation on human cells and tissues are relatively well defined, there is no consensus regarding the effects of low and very low radiation doses on the organism. Ionizing radiation has been shown to induce gene mutations and chromosome aberrations which are known to be involved in the process of carcinogenesis. The induction of secondary cancers is a challenging long-term side effect in oncologic patients treated with radiation. Medical sources of radiation like intensity modulated radiotherapy used in cancer treatment and computed tomography used in diagnostics, deliver very low doses of radiation to large volumes of healthy tissue, which might contribute to increased cancer rates in long surviving patients and in the general population. Research shows that because of the phenomena characteristic for low dose radiation the risk of cancer induction from exposure of healthy tissues to low dose radiation can be greater than the risk calculated from linear no-threshold model. Epidemiological data collected from radiation workers and atomic bomb survivors confirms that exposure to low dose radiation can contribute to increased cancer risk and also that the risk might correlate with the age at exposure.

  9. Dose trend analysis of the PWR nuclear power plants

    International Nuclear Information System (INIS)

    Cernilogar Radez, M.; Janzekovic, H.; Krizman, M.

    2002-01-01

    The analyses of occupational dose trends in Krsko NPP in the period from 1995 to 2001 are given in comparison to the worldwide data. The Central Dose Register of Workers in Nuclear Installations at the Slovenian Nuclear Safety Administration enables the comprehensive dose trend analysis of the occupational doses in Krsko NPP. The time dose trend of the collective annual effective dose at the Krsko NPP shows somehow different trend than the trends of the ISOE data [1]. The performance indicators describing dose data distributions related to the radiation protection standards [2, 3] are discussed.(author)

  10. Optimizing Radiation Doses for Computed Tomography Across Institutions: Dose Auditing and Best Practices.

    Science.gov (United States)

    Demb, Joshua; Chu, Philip; Nelson, Thomas; Hall, David; Seibert, Anthony; Lamba, Ramit; Boone, John; Krishnam, Mayil; Cagnon, Christopher; Bostani, Maryam; Gould, Robert; Miglioretti, Diana; Smith-Bindman, Rebecca

    2017-06-01

    Radiation doses for computed tomography (CT) vary substantially across institutions. To assess the impact of institutional-level audit and collaborative efforts to share best practices on CT radiation doses across 5 University of California (UC) medical centers. In this before/after interventional study, we prospectively collected radiation dose metrics on all diagnostic CT examinations performed between October 1, 2013, and December 31, 2014, at 5 medical centers. Using data from January to March (baseline), we created audit reports detailing the distribution of radiation dose metrics for chest, abdomen, and head CT scans. In April, we shared reports with the medical centers and invited radiology professionals from the centers to a 1.5-day in-person meeting to review reports and share best practices. We calculated changes in mean effective dose 12 weeks before and after the audits and meeting, excluding a 12-week implementation period when medical centers could make changes. We compared proportions of examinations exceeding previously published benchmarks at baseline and following the audit and meeting, and calculated changes in proportion of examinations exceeding benchmarks. Of 158 274 diagnostic CT scans performed in the study period, 29 594 CT scans were performed in the 3 months before and 32 839 CT scans were performed 12 to 24 weeks after the audit and meeting. Reductions in mean effective dose were considerable for chest and abdomen. Mean effective dose for chest CT decreased from 13.2 to 10.7 mSv (18.9% reduction; 95% CI, 18.0%-19.8%). Reductions at individual medical centers ranged from 3.8% to 23.5%. The mean effective dose for abdominal CT decreased from 20.0 to 15.0 mSv (25.0% reduction; 95% CI, 24.3%-25.8%). Reductions at individual medical centers ranged from 10.8% to 34.7%. The number of CT scans that had an effective dose measurement that exceeded benchmarks was reduced considerably by 48% and 54% for chest and abdomen, respectively. After

  11. The health effects of low-dose ionizing radiation

    International Nuclear Information System (INIS)

    Dixit, A.N.; Dixit, Nishant

    2012-01-01

    It has been established by various researches, that high doses of ionizing radiation are harmful to health. There is substantial controversy regarding the effects of low doses of ionizing radiation despite the large amount of work carried out (both laboratory and epidemiological). Exposure to high levels of radiation can cause radiation injury, and these injuries can be relatively severe with sufficiently high radiation doses. Prolonged exposure to low levels of radiation may lead to cancer, although the nature of our response to very low radiation levels is not well known at this time. Many of our radiation safety regulations and procedures are designed to protect the health of those exposed to radiation occupationally or as members of the public. According to the linear no-threshold (LNT) hypothesis, any amount, however small, of radiation is potentially harmful, even down to zero levels. The threshold hypothesis, on the other hand, emphasizes that below a certain threshold level of radiation exposure, any deleterious effects are absent. At the same time, there are strong arguments, both experimental and epidemiological, which support the radiation hormesis (beneficial effects of low-level ionizing radiation). These effects cannot be anticipated by extrapolating from harmful effects noted at high doses. Evidence indicates an inverse relationship between chronic low-dose radiation levels and cancer incidence and/or mortality rates. Examples are drawn from: 1) state surveys for more than 200 million people in the United States; 2) state cancer hospitals for 200 million people in India; 3) 10,000 residents of Taipei who lived in cobalt-60 contaminated homes; 4) high-radiation areas of Ramsar, Iran; 5) 12 million person-years of exposed and carefully selected control nuclear workers; 6) almost 300,000 radon measurements of homes in the United States; and 7) non-smokers in high-radon areas of early Saxony, Germany. This evidence conforms to the hypothesis that

  12. A radon progeny sampler for the determination of effective dose

    Energy Technology Data Exchange (ETDEWEB)

    Solomon, S.B. [Australian Radiation Laboratory, Victoria (Australia)

    1997-12-01

    The design and simulated performance is described of a two-stage sampler (HE-Sampler) for {sup 222}Rn progeny. This HE-Sampler has a collection efficiency optimised to match the particle size dependency of the radon progeny dose conversion factor (DCF), derived from the latest Respiratory Tract Model of the International Commission on Radiological Protection, as implemented in the computer code RADEP. The He-Sampler comprises a wire screen pre-separator, matched to the nasal deposition, and a wire screen collector, matched to the respiratory tract collection. This HE-Sampler allows for the estimation of the radiation dose from the inhalation of {sup 222}Rn progeny, derived from two concurrent alpha particle activity measurements, one on the HE-Sampler screen collector and one on a reference filter sample. As a first approximation, the DCF is proportional to the collected fraction. The HE-Sampler response was simulated for a range of radon progeny size distributions to determine the error in the estimated DCF values. The simulation results show that the HE-Sampler is relatively insensitive to variations in sampling rate and in the screen parameters, particularly for environmental exposure. (Author).

  13. Occupational radiation doses among diagnostic radiation workers in South Korea, 1996-2006

    International Nuclear Information System (INIS)

    Lee, W. J.; Cha, E. S.; Ha, M.; Jin, Y. W.; Hwang, S. S.; Kong, K. A.; Lee, S. W.; Lee, H. K.; Lee, K. Y.; Kim, H. J.

    2009-01-01

    This study details the distribution and trends of doses of occupational radiation among diagnostic radiation workers by using the national dose registry between 1996 and 2006 by the Korea Food and Drug Administration. Dose measurements were collected quarterly by the use of thermoluminescent dosemeter personal monitors. A total of 61 732 workers were monitored, including 18 376 radiologic technologists (30%), 13 762 physicians (22%), 9858 dentists (16%) and 6114 dental hygienists (9.9%). The average annual effective doses of all monitored workers decreased from 1.75 to 0.80 mSv over the study period. Among all diagnostic radiation workers, radiologic technologists received both the highest effective and collective doses. Male radiologic technologists aged 30-49 y composed the majority of workers receiving more than 5 mSv in a quarter. More intensive monitoring of occupational radiation exposure and investigation into its health effects on diagnostic radiation workers are required in South Korea. (authors)

  14. Dose-Dependent Protective Effect of Inhalational Anesthetics Against Postoperative Respiratory Complications

    DEFF Research Database (Denmark)

    Grabitz, Stephanie D; Farhan, Hassan N; Ruscic, Katarina J

    2017-01-01

    OBJECTIVES: Inhalational anesthetics are bronchodilators with immunomodulatory effects. We sought to determine the effect of inhalational anesthetic dose on risk of severe postoperative respiratory complications. DESIGN: Prospective analysis of data on file in surgical cases between January 2007...... with endotracheal intubation. INTERVENTIONS: Median effective dose equivalent of inhalational anesthetics during surgery (derived from mean end-tidal inhalational anesthetic concentrations). MEASUREMENTS AND MAIN RESULTS: Postoperative respiratory complications occurred in 6,979 of 124,497 cases (5.61%). High...... inhalational anesthetic dose of 1.20 (1.13-1.30) (median [interquartile range])-fold median effective dose equivalent versus 0.57 (0.45-0.64)-fold median effective dose equivalent was associated with lower odds of postoperative respiratory complications (odds ratio, 0.59; 95% CI, 0.53-0.65; p

  15. submitter Dose prescription in carbon ion radiotherapy: How to compare two different RBE-weighted dose calculation systems

    CERN Document Server

    Molinelli, Silvia; Mairani, Andrea; Matsufuji, Naruhiro; Kanematsu, Nobuyuki; Inaniwa, Taku; Mirandola, Alfredo; Russo, Stefania; Mastella, Edoardo; Hasegawa, Azusa; Tsuji, Hiroshi; Yamada, Shigeru; Vischioni, Barbara; Vitolo, Viviana; Ferrari, Alfredo; Ciocca, Mario; Kamada, Tadashi; Tsujii, Hirohiko; Orecchia, Roberto; Fossati, Piero

    2016-01-01

    Background and purpose: In carbon ion radiotherapy (CIRT), the use of different relative biological effectiveness (RBE) models in the RBE-weighted dose $(D_{RBE})$ calculation can lead to deviations in the physical dose $(D_{phy})$ delivered to the patient. Our aim is to reduce target $D_{phy}$ deviations by converting prescription dose values. Material and methods: Planning data of patients treated at the National Institute of Radiological Sciences (NIRS) were collected, with prescribed doses per fraction ranging from 3.6 Gy (RBE) to 4.6 Gy (RBE), according to the Japanese semi-empirical model. The $D_{phy}$ was Monte Carlo (MC) re-calculated simulating the NIRS beamline. The local effect model (LEM)_I was then applied to estimate $D_{RBE}$. Target median $D_{RBE}$ ratios between MC + LEM_I and NIRS plans determined correction factors for the conversion of prescription doses. Plans were re-optimized in a LEM_I-based commercial system, prescribing the NIRS uncorrected and corrected $D_{RBE}$. Results: The MC ...

  16. Trends in occupational and collective dose in the Czech Republic

    International Nuclear Information System (INIS)

    Petrova, K.; Prouza, Z.

    1998-01-01

    Recent new legislation in the Czech Republic (Law on Peaceful Use of Nuclear Energy and Ionizing Radiation [2]) is based on the ICRP Report 60 [3] and New International Basic Safety Standards [4]. Concerning the personal monitoring of workers, licensee will be responsible not only to designate controlled areas where specific protective measures are required for control of occupational radiation exposures (ORE) and prevention of the spread of contamination during normal working conditions, but shall also maintain exposure records for each worker for whom assessment of ORE is required. This duty of licensee is given in new Regulation on Radiation Protection No.184 adopted in August 1997 [1]. In accordance with this Regulation one duty of licensee is to send results of personal monitoring to the State Office for Nuclear Safety. The Central Registry of Occupational Exposures (CROE) was regularly established for this purpose in the State Office for Nuclear Safety and rules for handling, maintenance and protection of data were defined. The data collected in CROE were used for the evaluation of trends of occupational exposures in the Czech Republic in the period 1990 - 1994 years also for the UNSCEAR survey. Basic information about the methods used for ORE evaluation, comments for different occupational groups and general conclusions are presented. It is concluded that general trend of the occupational exposures in the Czech Republic is constant with the average value of effective dose equivalent 1.02 mSv (without workers in uranium industry). It is observed the slight increase of exposures in medicine related with the reorganisation on this field and significant decrease in uranium industry related with the suppression of uranium production. (author)

  17. Trends in occupational and collective dose in the Czech Republic

    Energy Technology Data Exchange (ETDEWEB)

    Petrova, K; Prouza, Z [State Office for Nuclear Safety, Prague (Czech Republic)

    1998-08-01

    Recent new legislation in the Czech Republic (Law on Peaceful Use of Nuclear Energy and Ionizing Radiation [2]) is based on the ICRP Report 60 [3] and New International Basic Safety Standards [4]. Concerning the personal monitoring of workers, licensee will be responsible not only to designate controlled areas where specific protective measures are required for control of occupational radiation exposures (ORE) and prevention of the spread of contamination during normal working conditions, but shall also maintain exposure records for each worker for whom assessment of ORE is required. This duty of licensee is given in new Regulation on Radiation Protection No.184 adopted in August 1997 [1]. In accordance with this Regulation one duty of licensee is to send results of personal monitoring to the State Office for Nuclear Safety. The Central Registry of Occupational Exposures (CROE) was regularly established for this purpose in the State Office for Nuclear Safety and rules for handling, maintenance and protection of data were defined. The data collected in CROE were used for the evaluation of trends of occupational exposures in the Czech Republic in the period 1990 - 1994 years also for the UNSCEAR survey. Basic information about the methods used for ORE evaluation, comments for different occupational groups and general conclusions are presented. It is concluded that general trend of the occupational exposures in the Czech Republic is constant with the average value of effective dose equivalent 1.02 mSv (without workers in uranium industry). It is observed the slight increase of exposures in medicine related with the reorganisation on this field and significant decrease in uranium industry related with the suppression of uranium production. (author) 6 refs, 6 figs

  18. An ALARA approach to collective dose control at RAPS-3 and 4

    International Nuclear Information System (INIS)

    Khandelwal, Narendra; Dhakar, P.C.; Gupta, Ashok

    2016-01-01

    At Rajasthan Atomic Power Station-3 and 4 (RAPS 3 and 4) immense efforts were put to achieve continual reduction in man rem consumption in every subsequent year and this could be done successfully through implementing design changes based on experience, reducing radiation levels by removing radioactive material from undesired locations, flushing of active system/equipment's, shielding of hot spots, minimizing D20 leaks, manpower optimization, improvement in work culture and strong management commitment etc. Radiation protection is a never ending process and scope is always available to reduce the doses at all levels. Routine radiation survey sometimes does not provide exact idea about potential of significant collective exposure that can take place when ambient radiation levels are comparable to background radiation levels

  19. Biological effects of low doses of ionizing radiation

    International Nuclear Information System (INIS)

    Gonzalez, A.J.

    1994-01-01

    Few weeks ago, when the United Nations Scientific Committee on the Effects of Atomic Radiation (UNSCEAR) submitted to the U.N. General Assembly the UNSCEAR 1994 report, the international community had at its disposal a broad view of the biological effects of low doses of ionizing radiation. The 1994 report (272 pages) specifically addressed the epidemiological studies of radiation carcinogenesis and the adaptive responses to radiation in cells and organisms. The report was aimed to supplement the UNSCEAR 1993 report to the U.N. General Assembly- an extensive document of 928 pages-which addressed the global levels of radiation exposing the world population, as well as some issues on the effects of ionizing radiation, including: mechanisms of radiation oncogenesis due to radiation exposure, influence of the level of dose and dose rate on stochastic effects of radiation, hereditary effects of radiation effects on the developing human brain, and the late deterministic effects in children. Those two UNSCEAR reports taken together provide an impressive overview of current knowledge on the biological effects of ionizing radiation. This article summarizes the essential issues of both reports, although it cannot cover all available information. (Author)

  20. Age-dependent effective doses for radionuclides uniformly distributed in air

    International Nuclear Information System (INIS)

    Hung, Tran Van

    2014-01-01

    Age-dependent effective doses for external exposure to photons emitted by radionuclides uniformly distributed in air are reported. The calculations were performed for 160 radionuclides, which are important for safety assessment of nuclear facilities. The energies and intensities of photons emitted from radionuclides were taken from the decay data DECDC used for dose calculations. The results are tabulated in the form of effective dose per unit concentration and time (Sv per Bq s m -3 ) for 6 age groups: newborn, 1, 5, 10 and 15 years-old and adult. The effective doses for the adult are also compared to values given in the literature.

  1. Estimating Effective Dose of Radiation From Pediatric Cardiac CT Angiography Using a 64-MDCT Scanner: New Conversion Factors Relating Dose-Length Product to Effective Dose.

    Science.gov (United States)

    Trattner, Sigal; Chelliah, Anjali; Prinsen, Peter; Ruzal-Shapiro, Carrie B; Xu, Yanping; Jambawalikar, Sachin; Amurao, Maxwell; Einstein, Andrew J

    2017-03-01

    The purpose of this study is to determine the conversion factors that enable accurate estimation of the effective dose (ED) used for cardiac 64-MDCT angiography performed for children. Anthropomorphic phantoms representative of 1- and 10-year-old children, with 50 metal oxide semiconductor field-effect transistor dosimeters placed in organs, underwent scanning performed using a 64-MDCT scanner with different routine clinical cardiac scan modes and x-ray tube potentials. Organ doses were used to calculate the ED on the basis of weighting factors published in 1991 in International Commission on Radiological Protection (ICRP) publication 60 and in 2007 in ICRP publication 103. The EDs and the scanner-reported dose-length products were used to determine conversion factors for each scan mode. The effect of infant heart rate on the ED and the conversion factors was also assessed. The mean conversion factors calculated using the current definition of ED that appeared in ICRP publication 103 were as follows: 0.099 mSv · mGy -1 · cm -1 , for the 1-year-old phantom, and 0.049 mSv · mGy -1 · cm -1 , for the 10-year-old phantom. These conversion factors were a mean of 37% higher than the corresponding conversion factors calculated using the older definition of ED that appeared in ICRP publication 60. Varying the heart rate did not influence the ED or the conversion factors. Conversion factors determined using the definition of ED in ICRP publication 103 and cardiac, rather than chest, scan coverage suggest that the radiation doses that children receive from cardiac CT performed using a contemporary 64-MDCT scanner are higher than the radiation doses previously reported when older chest conversion factors were used. Additional up-to-date pediatric cardiac CT conversion factors are required for use with other contemporary CT scanners and patients of different age ranges.

  2. Survey of computed tomography doses in head and chest protocols; Levantamento de doses em tomografia computadorizada em protocolos de cranio e torax

    Energy Technology Data Exchange (ETDEWEB)

    Souza, Giordana Salvi de; Silva, Ana Maria Marques da, E-mail: giordana.souza@acad.pucrs.br [Pontificia Universidade Catolica do Rio Grande do Sul (PUC-RS), Porto Alegre, RS (Brazil). Faculdade de Fisica. Nucleo de Pesquisa em Imagens Medicas

    2016-07-01

    Computed tomography is a clinical tool for the diagnosis of patients. However, the patient is subjected to a complex dose distribution. The aim of this study was to survey dose indicators in head and chest protocols CT scans, in terms of Dose-Length Product(DLP) and effective dose for adult and pediatric patients, comparing them with diagnostic reference levels in the literature. Patients were divided into age groups and the following image acquisition parameters were collected: age, kV, mAs, Volumetric Computed Tomography Dose Index (CTDIvol) and DLP. The effective dose was found multiplying DLP by correction factors. The results were obtained from the third quartile and showed the importance of determining kV and mAs values for each patient depending on the studied region, age and thickness. (author)

  3. A Monte Carlo estimation of effective dose in chest tomosynthesis

    International Nuclear Information System (INIS)

    Sabol, John M.

    2009-01-01

    Purpose: The recent introduction of digital tomosynthesis imaging into routine clinical use has enabled the acquisition of volumetric patient data within a standard radiographic examination. Tomosynthesis requires the acquisition of multiple projection views, requiring additional dose compared to a standard projection examination. Knowledge of the effective dose is needed to make an appropriate decision between standard projection, tomosynthesis, and CT for thoracic x-ray examinations. In this article, the effective dose to the patient of chest tomosynthesis is calculated and compared to a standard radiographic examination and to values published for thoracic CT. Methods: Radiographic technique data for posterior-anterior (PA) and left lateral (LAT) radiographic chest examinations of medium-sized adults was obtained from clinical sites. From these data, the average incident air kerma for the standard views was determined. A commercially available tomosynthesis system was used to define the acquisition technique and geometry for each projection view. Using Monte Carlo techniques, the effective dose of the PA, LAT, and each tomosynthesis projection view was calculated. The effective dose for all projections of the tomosynthesis sweep was summed and compared to the calculated PA and LAT values and to the published values for thoracic CT. Results: The average incident air kerma for the PA and left lateral clinical radiographic examinations were found to be 0.10 and 0.40 mGy, respectively. The effective dose for the PA view of a patient of the size of an average adult male was determined to be 0.017 mSv (ICRP 60) [0.018 mSv (ICRP 103)]. For the left lateral view of the same sized patient, the effective dose was determined to be 0.039 mSv (ICRP 60) [0.050 mSv (ICRP 103)]. The cumulative mA s for a tomosynthesis examination is recommended to be ten times the mA s of the PA image. With this technique, the effective dose for an average tomosynthesis examination was

  4. A simple method for estimating the effective dose in dental CT. Conversion factors and calculation for a clinical low-dose protocol

    International Nuclear Information System (INIS)

    Homolka, P.; Kudler, H.; Nowotny, R.; Gahleitner, A.; Wien Univ.

    2001-01-01

    An easily appliable method to estimate effective dose including in its definition the high radio-sensitivity of the salivary glands from dental computed tomography is presented. Effective doses were calculated for a markedly dose reduced dental CT protocol as well as for standard settings. Data are compared with effective doses from the literature obtained with other modalities frequently used in dental care. Methods: Conversion factors based on the weighted Computed Tomography Dose Index were derived from published data to calculate effective dose values for various CT exposure settings. Results: Conversion factors determined can be used for clinically used kVp settings and prefiltrations. With reduced tube current an effective dose for a CT examination of the maxilla of 22 μSv can be achieved, which compares to values typically obtained with panoramic radiography (26 μSv). A CT scan of the mandible, respectively, gives 123 μSv comparable to a full mouth survey with intraoral films (150 μSv). Conclusion: For standard CT scan protocols of the mandible, effective doses exceed 600 μSv. Hence, low dose protocols for dental CT should be considered whenever feasable, especially for paediatric patients. If hard tissue diagnoses is performed, the potential of dose reduction is significant despite the higher image noise levels as readability is still adequate. (orig.) [de

  5. Effective dose and cancer risk in PET/CT exams; Dose efetiva e risco de cancer em exames de PET/CT

    Energy Technology Data Exchange (ETDEWEB)

    Pinto, Gabriella M.; Sa, Lidia Vasconcellos de, E-mail: montezano@ird.gov.br, E-mail: Iidia@ird.gov.br [Instituto de Radioprotecao e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil)

    2013-07-01

    Due to the use of radiopharmaceutical positron-emitting in PET exam and realization of tomography by x-ray transmission in CT examination, an increase of dose with hybrid PET/CT technology is expected. However, differences of doses have been reported in many countries for the same type of procedure. It is expected that the dose is an influent parameter to standardize the protocols of PET/CT. This study aimed to estimate the effective doses and absorbed in 65 patients submitted to oncological Protocol in a nuclear medicine clinic in Rio de Janeiro, considering the risk of induction of cancer from the scan. The CT exam-related doses were estimated with a simulator of PMMA and simulated on the lmPACT resistance, which for program effective dose, were considered the weight factors of the lCRP 103. The PET exam doses were estimated by multiplying the activity administered to the patient with the ICRP dose 80 factors. The radiological risk for cancer incidence were estimated according to the ICRP 103. The results showed that the effective dose from CT exam is responsible for 70% of the effective total in a PET/CT scan. values of effective dose for the PET/CT exam reached average values of up to 25 mSv leading to a risk of 2, 57 x 10{sup -4}. Considering that in staging of oncological diseases at least four tests are performed annually, the total risk comes to 1,03x 10{sup -3}.

  6. Evaluation of effective dose equivalent from environmental gamma rays

    International Nuclear Information System (INIS)

    Saito, K.; Tsutsumi, M.; Moriuchi, S.; Petoussi, N.; Zankl, M.; Veit, R.; Jacob, P.; Drexler, G.

    1991-01-01

    Organ doses and effective dose equivalents for environmental gamma rays were calculated using human phantoms and Monte Carlo methods accounting rigorously the environmental gamma ray fields. It was suggested that body weight is the dominant factor to determine organ doses. The weight function expressing organ doses was introduced. Using this function, the variation in organ doses due to several physical factors were investigated. A detector having gamma-ray response similar to that of human bodies has been developed using a NaI(Tl) scintillator. (author)

  7. Single and Multiple Ascending-dose Studies of Oral Delafloxacin: Effects of Food, Sex, and Age.

    Science.gov (United States)

    Hoover, Randall; Hunt, Thomas; Benedict, Michael; Paulson, Susan K; Lawrence, Laura; Cammarata, Sue; Sun, Eugene

    2016-01-01

    The objective of this report is describe the results of 2 studies that examined the pharmacokinetic parameters, safety profile, and tolerability of single and multiple ascending doses of oral delafloxacin and the effects of food, sex, and age on oral delafloxacin pharmacokinetic parameters, safety profile, and tolerability. The first study contained 3 parts and used unformulated delafloxacin in a capsule. Part 1 was a randomized, double-blind, placebo-controlled, single (50, 100, 200, 400, 800, 1200, and 1600 mg) ascending-dose study of oral delafloxacin in healthy men. Part 2 was a single-dose crossover study in which 20 men received 250 mg delafloxacin with or without food. Part 2 also included a parallel group, double-blind, placebo-controlled study in 16 women and 16 elderly men and women who were randomized (3:1) to receive 250 mg delafloxacin or placebo. Part 3 was a randomized, double-blind, placebo-controlled, multiple (100, 200, 400, 800, 1200 mg once daily for 5 days) ascending-dose study of oral delafloxacin in healthy men. The second study was a single-dose, randomized, 3-period crossover study in which participants received 900 mg delafloxacin (2 × 450-mg tablets) under fasted conditions, with a high-fat meal, or fasted with a high-fat meal 2 hours after dosing. Serial blood samples were collected, and plasma pharmacokinetic parameters of delafloxacin were determined. Delafloxacin Cmax and AUC0-∞ increased with increasing oral dose over the dose range of 50 to 1600 mg. The increases in delafloxacin AUC0-∞ were dose proportional at doses of ≥200 mg. Steady state was reached by day 3 of dosing with minimal accumulation of delafloxacin. The Cmax of delafloxacin was decreased slightly in the presence of food. No sex difference in delafloxacin pharmacokinetic parameters was observed. In the elderly men and women, mean delafloxacin Cmax and AUC0-∞ were 35% higher than observed for young adults, which could be partially explained by a decrease in

  8. Assessment of Annual Effective Dose for Natural Radioactivity of Gamma Emitters in Biscuit Samples in Iraq.

    Science.gov (United States)

    Abojassim, Ali Abid; Al-Alasadi, Lubna A; Shitake, Ahmed R; Al-Tememie, Faeq A; Husain, Afnan A

    2015-09-01

    Biscuits are an important type of food, widely consumed by babies in Iraq and other countries. This work uses gamma spectroscopy to measure the natural radioactivity due to long-lived gamma emitters in children's biscuits; it also estimates radiation hazard indices, that is, the radium equivalent activity, the representative of gamma level index, the internal hazard index, and the annual effective dose in children. Ten samples were collected from the Iraqi market from different countries of origin. The average specific activities for (226)Ra, (232)Th, and (40)K were 9.390, 3.1213, and 214.969 Bq/kg, respectively, but the average of the radium equivalent activity and the internal hazard index were 33.101 Bq/kg and 0.107, respectively. The total average annual effective dose from consumption by adults, children, and infants is estimated to be 0.655, 1.009, and 0.875 mSv, respectively. The values found for specific activity, radiation hazard indices, and annual effective dose in all samples in this study were lower than worldwide median values for all groups; therefore, these values are found to be safe.

  9. Uncertainties in effective dose estimates of adult CT head scans: The effect of head size

    International Nuclear Information System (INIS)

    Gregory, Kent J.; Bibbo, Giovanni; Pattison, John E.

    2009-01-01

    Purpose: This study is an extension of a previous study where the uncertainties in effective dose estimates from adult CT head scans were calculated using four CT effective dose estimation methods, three of which were computer programs (CT-EXPO, CTDOSIMETRY, and IMPACTDOSE) and one that involved the dose length product (DLP). However, that study did not include the uncertainty contribution due to variations in head sizes. Methods: The uncertainties due to head size variations were estimated by first using the computer program data to calculate doses to small and large heads. These doses were then compared with doses calculated for the phantom heads used by the computer programs. An uncertainty was then assigned based on the difference between the small and large head doses and the doses of the phantom heads. Results: The uncertainties due to head size variations alone were found to be between 4% and 26% depending on the method used and the patient gender. When these uncertainties were included with the results of the previous study, the overall uncertainties in effective dose estimates (stated at the 95% confidence interval) were 20%-31% (CT-EXPO), 15%-30% (CTDOSIMETRY), 20%-36% (IMPACTDOSE), and 31%-40% (DLP). Conclusions: For the computer programs, the lower overall uncertainties were still achieved when measured values of CT dose index were used rather than tabulated values. For DLP dose estimates, head size variations made the largest (for males) and second largest (for females) contributions to effective dose uncertainty. An improvement in the uncertainty of the DLP method dose estimates will be achieved if head size variation can be taken into account.

  10. Uncertainties in effective dose estimates of adult CT head scans: The effect of head size

    Energy Technology Data Exchange (ETDEWEB)

    Gregory, Kent J.; Bibbo, Giovanni; Pattison, John E. [Department of Medical Physics, Royal Adelaide Hospital, Adelaide, South Australia 5000 (Australia) and School of Electrical and Information Engineering (Applied Physics), University of South Australia, Mawson Lakes, South Australia 5095 (Australia); Division of Medical Imaging, Women' s and Children' s Hospital, North Adelaide, South Australia 5006 (Australia) and School of Electrical and Information Engineering (Applied Physics), University of South Australia, Mawson Lakes, South Australia 5095 (Australia); School of Electrical and Information Engineering (Applied Physics), University of South Australia, Mawson Lakes, South Australia 5095 (Australia)

    2009-09-15

    Purpose: This study is an extension of a previous study where the uncertainties in effective dose estimates from adult CT head scans were calculated using four CT effective dose estimation methods, three of which were computer programs (CT-EXPO, CTDOSIMETRY, and IMPACTDOSE) and one that involved the dose length product (DLP). However, that study did not include the uncertainty contribution due to variations in head sizes. Methods: The uncertainties due to head size variations were estimated by first using the computer program data to calculate doses to small and large heads. These doses were then compared with doses calculated for the phantom heads used by the computer programs. An uncertainty was then assigned based on the difference between the small and large head doses and the doses of the phantom heads. Results: The uncertainties due to head size variations alone were found to be between 4% and 26% depending on the method used and the patient gender. When these uncertainties were included with the results of the previous study, the overall uncertainties in effective dose estimates (stated at the 95% confidence interval) were 20%-31% (CT-EXPO), 15%-30% (CTDOSIMETRY), 20%-36% (IMPACTDOSE), and 31%-40% (DLP). Conclusions: For the computer programs, the lower overall uncertainties were still achieved when measured values of CT dose index were used rather than tabulated values. For DLP dose estimates, head size variations made the largest (for males) and second largest (for females) contributions to effective dose uncertainty. An improvement in the uncertainty of the DLP method dose estimates will be achieved if head size variation can be taken into account.

  11. Doses to patients from dental radiology in France

    International Nuclear Information System (INIS)

    Benedittini, M.; Maccia, C.; Lefaure, C.; Fagnani, F.

    1989-01-01

    In France, a national study was undertaken to estimate both dental radiology practices (equipment and activity) and the associated population collective dose. This study was done in two steps: A nationwide survey was conducted on the practitioner categories involved in dental radiology, and dosimetric measurements were performed on patients and on an anthropomorphic phantom by using conventional dental x-ray machines and pantomographic units. A total of 27.5 x 10(6) films were estimated to have been performed in 1984; 6% of them were pantomographic and 94% were conventional. Most of the organ doses measured for one intra-oral film were lower than 1 mGy (100 mrad); pantomogram dose values were generally higher than intra-oral ones. The collective effective dose equivalent figure was 2,000 person-Sv (2 x 10(5) person rem) leading to a per head dose equivalent of 0.037 mSv (3.7 mrem). The study allowed authors to identify ways to reduce the patient dose in France (e.g., implementing the use of long cone devices and controlling darkroom practices)

  12. Total dose effects on ATLAS-SCT front-end electronics

    CERN Document Server

    Ullán, M; Dubbs, T; Grillo, A A; Spencer, E; Seiden, A; Spieler, H; Gilchriese, M G D; Lozano, M

    2002-01-01

    Low dose rate effects (LDRE) in bipolar technologies complicate the hardness assurance testing for high energy physics applications. The damage produced in the ICs in the real experiment can be underestimated if fast irradiations are carried out, while experiments done at the real dose rate are usually unpractical due to the still high total doses involved. In this work the sensitivity to LDRE of two bipolar technologies proposed for the ATLAS-SCT experiment at CERN is evaluated, finding one of them free of those effects. (12 refs).

  13. The relationships between radiation doses and their effects

    International Nuclear Information System (INIS)

    Beau, P.G.; Nenot, J.C.

    1982-01-01

    Dose-effect relationships have been developed both for the biological effects studied by Radiobiology and the long-term pathological effects (malignant diseases) studied by Radiation Protection. The former approach chiefly considers the primary biological injuries at the cellular level, and the relationship between the dependent variable characteristic of the effect and the dose -an independent variable- has an explanatory meaning. The parameters associated to the independent variable have a biophysical signification and fit into a model of the action of ionizing radiations. In the latter approach, the relationship is pragmatic and the previous parameters are just the results of a curve-fitting procedure realized on experimental or human data. The biophysical models have led to a general formulation associating a linear term to a quadratic term both of them weighted by an exponential term describing cellular killing at the highest doses. To a certain extent the curves obtained for leukemias, bronchopulmonary and breast cancers prove the validity of the pragmatic model [fr

  14. Determination of effective dose in pediatric radiodiagnostic in Medellin-Colombia

    International Nuclear Information System (INIS)

    Garzon, William J.; Aramburo, Javier M.; Jimenez, Angelmiro A.; Ortiz, Anselmo P.

    2013-01-01

    In order to know the effective dose in pediatric X-ray exams of chest, entrance surface dose measurements were performed for ages 1,5 and 10 years in the largest pediatric hospital in the city of Medellin, Colombia. The effective dose was obtained from applying the conversion coefficients to measures of the entrance surface dose (ESD) in 306 radiographic studies in AP and LAT I projections. The results were validated with PCXMC 2.0 computer program and other work reported in the literature. (author)

  15. Effective dose range for dental cone beam computed tomography scanners

    International Nuclear Information System (INIS)

    Pauwels, Ruben; Beinsberger, Jilke; Collaert, Bruno; Theodorakou, Chrysoula; Rogers, Jessica; Walker, Anne; Cockmartin, Lesley; Bosmans, Hilde; Jacobs, Reinhilde; Bogaerts, Ria; Horner, Keith

    2012-01-01

    Objective: To estimate the absorbed organ dose and effective dose for a wide range of cone beam computed tomography scanners, using different exposure protocols and geometries. Materials and methods: Two Alderson Radiation Therapy anthropomorphic phantoms were loaded with LiF detectors (TLD-100 and TLD-100H) which were evenly distributed throughout the head and neck, covering all radiosensitive organs. Measurements were performed on 14 CBCT devices: 3D Accuitomo 170, Galileos Comfort, i-CAT Next Generation, Iluma Elite, Kodak 9000 3D, Kodak 9500, NewTom VG, NewTom VGi, Pax-Uni3D, Picasso Trio, ProMax 3D, Scanora 3D, SkyView, Veraviewepocs 3D. Effective dose was calculated using the ICRP 103 (2007) tissue weighting factors. Results: Effective dose ranged between 19 and 368 μSv. The largest contributions to the effective dose were from the remainder tissues (37%), salivary glands (24%), and thyroid gland (21%). For all organs, there was a wide range of measured values apparent, due to differences in exposure factors, diameter and height of the primary beam, and positioning of the beam relative to the radiosensitive organs. Conclusions: The effective dose for different CBCT devices showed a 20-fold range. The results show that a distinction is needed between small-, medium-, and large-field CBCT scanners and protocols, as they are applied to different indication groups, the dose received being strongly related to field size. Furthermore, the dose should always be considered relative to technical and diagnostic image quality, seeing that image quality requirements also differ for patient groups. The results from the current study indicate that the optimisation of dose should be performed by an appropriate selection of exposure parameters and field size, depending on the diagnostic requirements.

  16. A review of data on the effects of low and low dose-rate radiation with special reference to the dose limit problem

    International Nuclear Information System (INIS)

    Matsudaira, Hiromichi

    1977-01-01

    This is a review of data pertaining to detection and quantification of the effects after exposure to low LET radiations delivered at low and low dose-rate, i.e., at a level of maximum permissible dose for the radiation workers, on experimental materials ranging from plant to rodents and on some human populations. Irradiation at a dose of a few rad is reported to induce mutation or malignant transformation in some selected model systems, with a linear dose-effect relationship. Moreover, the incidence of the chromosome aberrations in spermatocytes is reported to be elevated in the scorpiones (Tityus bahiensis) collected in a region of high natural background radiations (several rem/year). An increase in the incidence of childhood malignancies is reported among children exposed in utero to diagnostic X-rays. Appreciable increase in the incidence of genetic diseases due possibly to chromosome aberrations is also reported among population living in a region of high natural background radiations. Points are raised and discussed as to the interpretation and particularly application of these data to the estimation of somatic and genetic risks of human population from man-made radiations. Recent attempts of risk-benefit analysis with populations subjected to mass X-ray examination of the chest and stomac are referred to. Since we are unaware of the actual injuries due to the exposure even at the level of radiation workers (5 rem/year), it is out of the capacity of a biologist to afford the basis for the decision of limiting the exposure of general population due to the light water reactor operation to 5 mrem/year. (auth.)

  17. Effective dose estimation to patients and staff during urethrography procedures

    International Nuclear Information System (INIS)

    Sulieman, A.; Barakat, H.; Alkhorayef, M.; Babikir, E.; Dalton, A.; Bradley, D.

    2015-10-01

    Medical-related radiation is the largest source of controllable radiation exposure to humans and it accounts for more than 95% of radiation exposure from man-made sources. Few data were available worldwide regarding patient and staff dose during urological ascending urethrography (ASU) procedure. The purposes of this study are to measure patient and staff entrance surface air kerma dose (ESAK) during ASU procedure and evaluate the effective doses. A total of 243 patients and 145 staff (Urologist) were examined in three Hospitals in Khartoum state. ESAKs were measured for patient and staff using thermoluminescent detectors (TLDs). Effective doses (E) were calculated using published conversion factors and methods recommended by the national Radiological Protection Board (NRPB). The mean ESAK dose for patients and staff dose were 7.79±6.7 mGy and 0.161±0.30 mGy per procedures respectively. The mean and range of the effective dose was 1.21 mSv per procedure. The radiation dose in this study is comparable with previous studies except Hospital C. It is obvious that high patient and staff exposure is due to the lack of experience and protective equipment s. Interventional procedures remain operator dependent; therefore continuous training is crucial. (Author)

  18. Effective dose estimation to patients and staff during urethrography procedures

    Energy Technology Data Exchange (ETDEWEB)

    Sulieman, A. [Prince Sattam bin Abdulaziz University, College of Applied Medical Sciences, Radiology and Medical Imaging Department, P. O- Box 422, Alkharj 11942 (Saudi Arabia); Barakat, H. [Neelain University, College of Science and Technology, Medical Physics Department, Khartoum (Sudan); Alkhorayef, M.; Babikir, E. [King Saud University, College of Applied Sciences, Radiological Sciences Department, P. O. Box 10219, Riyadh 11433 (Saudi Arabia); Dalton, A.; Bradley, D. [University of Surrey, Centre for Nuclear and Radiation Physics, Department of Physics, Surrey, GU2 7XH Guildford (United Kingdom)

    2015-10-15

    Medical-related radiation is the largest source of controllable radiation exposure to humans and it accounts for more than 95% of radiation exposure from man-made sources. Few data were available worldwide regarding patient and staff dose during urological ascending urethrography (ASU) procedure. The purposes of this study are to measure patient and staff entrance surface air kerma dose (ESAK) during ASU procedure and evaluate the effective doses. A total of 243 patients and 145 staff (Urologist) were examined in three Hospitals in Khartoum state. ESAKs were measured for patient and staff using thermoluminescent detectors (TLDs). Effective doses (E) were calculated using published conversion factors and methods recommended by the national Radiological Protection Board (NRPB). The mean ESAK dose for patients and staff dose were 7.79±6.7 mGy and 0.161±0.30 mGy per procedures respectively. The mean and range of the effective dose was 1.21 mSv per procedure. The radiation dose in this study is comparable with previous studies except Hospital C. It is obvious that high patient and staff exposure is due to the lack of experience and protective equipment s. Interventional procedures remain operator dependent; therefore continuous training is crucial. (Author)

  19. Incorporating partial shining effects in proton pencil-beam dose calculation

    International Nuclear Information System (INIS)

    Li Yupeng; Zhang Xiaodong; Lii Mingfwu; Sahoo, Narayan; Zhu, Ron X; Gillin, Michael; Mohan, Radhe

    2008-01-01

    A range modulator wheel (RMW) is an essential component in passively scattered proton therapy. We have observed that a proton beam spot may shine on multiple steps of the RMW. Proton dose calculation algorithms normally do not consider the partial shining effect, and thus overestimate the dose at the proximal shoulder of spread-out Bragg peak (SOBP) compared with the measurement. If the SOBP is adjusted to better fit the plateau region, the entrance dose is likely to be underestimated. In this work, we developed an algorithm that can be used to model this effect and to allow for dose calculations that better fit the measured SOBP. First, a set of apparent modulator weights was calculated without considering partial shining. Next, protons spilled from the accelerator reaching the modulator wheel were simplified as a circular spot of uniform intensity. A weight-splitting process was then performed to generate a set of effective modulator weights with the partial shining effect incorporated. The SOBPs of eight options, which are used to label different combinations of proton-beam energy and scattering devices, were calculated with the generated effective weights. Our algorithm fitted the measured SOBP at the proximal and entrance regions much better than the ones without considering partial shining effect for all SOBPs of the eight options. In a prostate patient, we found that dose calculation without considering partial shining effect underestimated the femoral head and skin dose

  20. Exposures at low doses and biological effects of ionizing radiations

    International Nuclear Information System (INIS)

    Masse, R.

    2000-01-01

    Everyone is exposed to radiation from natural, man-made and medical sources, and world-wide average annual exposure can be set at about 3.5 mSv. Exposure to natural sources is characterised by very large fluctuations, not excluding a range covering two orders of magnitude. Millions of inhabitants are continuously exposed to external doses as high as 10 mSv per year, delivered at low dose rates, very few workers are exposed above the legal limit of 50 mSv/year, and referring to accidental exposures, only 5% of the 116 000 people evacuated following the Chernobyl disaster encountered doses above 100 mSv. Epidemiological survey of accidentally, occupationally or medically exposed groups have revealed radio-induced cancers, mostly following high dose-rate exposure levels, only above 100 mSv. Risk coefficients were derived from these studies and projected into linear models of risk (linear non-threshold hypothesis: LNT), for the purpose of risk management following exposures at low doses and low dose-rates. The legitimacy of this approach has been questioned, by the Academy of sciences and the Academy of medicine in France, arguing: that LNT was not supported by Hiroshima and Nagasaki studies when neutron dose was revisited; that linear modelling failed to explain why so many site-related cancers were obviously nonlinearly related to the dose, and especially when theory predicted they ought to be; that no evidence could be found of radio-induced cancers related to natural exposures or to low exposures at the work place; and that no evidence of genetic disease could be shown from any of the exposed groups. Arguments were provided from cellular and molecular biology helping to solve this issue, all resulting in dismissing the LNT hypothesis. These arguments included: different mechanisms of DNA repair at high and low dose rate; influence of inducible stress responses modifying mutagenesis and lethality; bystander effects allowing it to be considered that individual

  1. Estimation and comparison of effective dose (E) in standard chest CT by organ dose measurements and dose-length-product methods and assessment of the influence of CT tube potential (energy dependency) on effective dose in a dual-source CT.

    Science.gov (United States)

    Paul, Jijo; Banckwitz, Rosemarie; Krauss, Bernhard; Vogl, Thomas J; Maentele, Werner; Bauer, Ralf W

    2012-04-01

    To determine effective dose (E) during standard chest CT using an organ dose-based and a dose-length-product-based (DLP) approach for four different scan protocols including high-pitch and dual-energy in a dual-source CT scanner of the second generation. Organ doses were measured with thermo luminescence dosimeters (TLD) in an anthropomorphic male adult phantom. Further, DLP-based dose estimates were performed by using the standard 0.014mSv/mGycm conversion coefficient k. Examinations were performed on a dual-source CT system (Somatom Definition Flash, Siemens). Four scan protocols were investigated: (1) single-source 120kV, (2) single-source 100kV, (3) high-pitch 120kV, and (4) dual-energy with 100/Sn140kV with equivalent CTDIvol and no automated tube current modulation. E was then determined following recommendations of ICRP publication 103 and 60 and specific k values were derived. DLP-based estimates differed by 4.5-16.56% and 5.2-15.8% relatively to ICRP 60 and 103, respectively. The derived k factors calculated from TLD measurements were 0.0148, 0.015, 0.0166, and 0.0148 for protocol 1, 2, 3 and 4, respectively. Effective dose estimations by ICRP 103 and 60 for single-energy and dual-energy protocols show a difference of less than 0.04mSv. Estimates of E based on DLP work equally well for single-energy, high-pitch and dual-energy CT examinations. The tube potential definitely affects effective dose in a substantial way. Effective dose estimations by ICRP 103 and 60 for both single-energy and dual-energy examinations differ not more than 0.04mSv. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  2. Determining effective radiation mutagen dose for garlic (Allium sativum L.)

    International Nuclear Information System (INIS)

    Taner, Y.; Kunter, B.

    2004-01-01

    This study was carried out to get database for future garlic mutation breeding studies. For this aim, 0, 5, 10, 15, 20, 25 and 30 Gy doses of Cs 137 (gamma-ray) were applied on garlic cloves as a physical mutagen. 50 cloves were used for each dose. Sixty days after treatment, germination rate and shoot development of cloves were determined. The Effective Mutagen Dose (ED 50 ) was calculated by regression analyses. According to the results, 4.455 Gy dose was found to be effective as ED 50 . (author)

  3. Correlation between effective dose and radiological risk: general concepts

    Energy Technology Data Exchange (ETDEWEB)

    Costa, Paulo Roberto; Yoshimura, Elisabeth Mateus; Nersissian, Denise Yanikian; Melo, Camila Souza, E-mail: pcosta@if.usp.br [Universidade de Sao Paulo (IF/USP), Sao Paulo, SP (Brazil). Instituto de Fisica

    2016-05-15

    The present review aims to offer an educational approach related to the limitations in the use of the effective dose magnitude as a tool for the quantification of doses resulting from diagnostic applications of ionizing radiation. We present a critical analysis of the quantities accepted and currently used for dosimetric evaluation in diagnostic imaging procedures, based on studies published in the literature. It is highlighted the use of these quantities to evaluate the risk attributed to the procedure and to calculate the effective dose, as well as to determine its correct use and interpretation. (author)

  4. Automated size-specific CT dose monitoring program: Assessing variability in CT dose

    Energy Technology Data Exchange (ETDEWEB)

    Christianson, Olav; Li Xiang; Frush, Donald; Samei, Ehsan [Clinical Imaging Physics Group, Department of Radiology, Duke University Medical Center, Durham, North Carolina 27705 and Department of Radiology, Duke University Medical Center, Durham, North Carolina 27705 (United States); Clinical Imaging Physics Group, Department of Radiology, Duke University Medical Center, Durham, North Carolina 27705 (United States); Department of Radiology, Duke University Medical Center, Durham, North Carolina 27705 (United States) and Carl E. Ravin Advanced Imaging Laboratories, Department of Radiology, Duke University Medical Center, Durham, North Carolina 27705 (United States); Department of Radiology, Duke University Medical Center, Durham, North Carolina 27705 (United States); Clinical Imaging Physics Group, Department of Radiology, Duke University Medical Center, Durham, North Carolina 27705 (United States); Department of Radiology, Duke University Medical Center, Durham, North Carolina 27705 (United States); Carl E. Ravin Advanced Imaging Laboratories, Department of Radiology, Duke University Medical Center, Durham, North Carolina 27705 (United States); Medical Physics Graduate Program, Duke University, Durham, North Carolina 27705 (United States); Department of Physics, Duke University, Durham, North Carolina 27710 (United States); and Department of Biomedical Engineering, Duke University, Durham, North Carolina 27708 (United States)

    2012-11-15

    Purpose: The potential health risks associated with low levels of ionizing radiation have created a movement in the radiology community to optimize computed tomography (CT) imaging protocols to use the lowest radiation dose possible without compromising the diagnostic usefulness of the images. Despite efforts to use appropriate and consistent radiation doses, studies suggest that a great deal of variability in radiation dose exists both within and between institutions for CT imaging. In this context, the authors have developed an automated size-specific radiation dose monitoring program for CT and used this program to assess variability in size-adjusted effective dose from CT imaging. Methods: The authors radiation dose monitoring program operates on an independent health insurance portability and accountability act compliant dosimetry server. Digital imaging and communication in medicine routing software is used to isolate dose report screen captures and scout images for all incoming CT studies. Effective dose conversion factors (k-factors) are determined based on the protocol and optical character recognition is used to extract the CT dose index and dose-length product. The patient's thickness is obtained by applying an adaptive thresholding algorithm to the scout images and is used to calculate the size-adjusted effective dose (ED{sub adj}). The radiation dose monitoring program was used to collect data on 6351 CT studies from three scanner models (GE Lightspeed Pro 16, GE Lightspeed VCT, and GE Definition CT750 HD) and two institutions over a one-month period and to analyze the variability in ED{sub adj} between scanner models and across institutions. Results: No significant difference was found between computer measurements of patient thickness and observer measurements (p= 0.17), and the average difference between the two methods was less than 4%. Applying the size correction resulted in ED{sub adj} that differed by up to 44% from effective dose

  5. Conditioned instrumental behaviour in the rat: Effects of prenatal irradiation with various low dose-rate doses

    International Nuclear Information System (INIS)

    Klug, H.

    1986-01-01

    4 groups of rats of the Wistar-strain were subjected to γ-irradiation on the 16th day of gestation. 5 rats received 0,6 Gy low dose rate irradiation, 5 animals received 0,9 Gy low dose and 6 high dose irradiation, 3 females were shamirradiated. The male offspring of these 3 irradiation groups and 1 control group were tested for locomotor coordination on parallel bars and in a water maze. The female offspring were used in an operant conditioning test. The locomotor test showed slight impairment of locomotor coordination in those animals irradiated with 0,9 Gy high dose rate. Swimming ability was significantly impaired by irradiation with 0,9 Gy high dose rate. Performance in the operant conditioning task was improved by irradiation with 0,9 Gy both low and high dose rate. The 0,9 Gy high dose rate group learned faster than all the other groups. For the dose of 0,9 Gy a significant dose rate effect could be observed. For the dose of 0,6 Gy a similar tendency was observed, differences between 0,6 Gy high and low dose rate and controls not being significant. (orig./MG) [de

  6. Dose rate effect on material aging due to radiation. [Gamma radiation

    Energy Technology Data Exchange (ETDEWEB)

    Okamoto, Shin-ichi (Radiation Center of Osaka Prefecture, Sakai (Japan)); Hayakawa, Chikara; Takeya, Chikashi

    1982-12-01

    Although many reports have been presented on the radiation aging of the organic materials for electric cables, those have been based on the experiments carried out at high dose rate near 1 x 10/sup 6/ rad/h, assuming that aging effect depends on only radiation dose. Therefore, to investigate the aging behaviour in low dose rate range is an important subject to predict their practical life time. In this report, the results of having investigated the aging behaviour of six types of materials are described, (polyethylene for general insulation purpose, chemically cross-linked polyethylene, fire-retardant chemically cross-linked polyethylene, fire-retardant ethylene-propylene rubber, fire-retardant chloro-sulfonated polyethylene for sheaths, and fire-retardant, low hydrochloric acid, special heat-resistant vinyl for insulation purpose or chloroclean). They were irradiated with /sup 60/Co ..gamma..-ray at the dose from 5 x 10/sup 3/ to 1 x 10/sup 6/ rad/h, and their deterioration was tested for the items of elongation, tensile strength, resistivity, dielectric tangent and gel fraction. The aging mechanism and dose rate effect were also considered. The dose rate effect appeared or did not appear depending on the types of materials and also their properties. The materials that showed the dose rate effect included the typical ones whose characteristics degraded with the decreasing dose rate, and the peculiar ones whose deterioration of characteristics did not appear constantly. Aging mechanism may vary in the case of high dose rate and low dose rate. Also, if the life time at respective dose rate in relatively higher dose rate region is clarified, the life time in low dose rate region may possibly be predicted.

  7. An open label, dose response study to determine the effect of a dietary supplement on dihydrotestosterone, testosterone and estradiol levels in healthy males

    Directory of Open Access Journals (Sweden)

    Anderson Mark L

    2008-08-01

    Full Text Available Abstract Background Maintaining endogenous testosterone (T levels as men age may slow the symptoms of sarcopenia, andropause and decline in physical performance. Drugs inhibiting the enzyme 5α-reductase (5AR produce increased blood levels of T and decreased levels of dihydrotestosterone (DHT. However, symptoms of gynecomastia have been reported due to the aromatase (AER enzyme converting excess T to estradiol (ES. The carotenoid astaxanthin (AX from Haematococcus pluvialis, Saw Palmetto berry lipid extract (SPLE from Serenoa repens and the precise combination of these dietary supplements, Alphastat® (Mytosterone(™, have been reported to have inhibitory effects on both 5AR and AER in-vitro. Concomitant regulation of both enzymes in-vivo would cause DHT and ES blood levels to decrease and T levels to increase. The purpose of this clinical study was to determine if patented Alphastat® (Mytosterone(™ could produce these effects in a dose dependent manner. Methods To investigate this clinically, 42 healthy males ages 37 to 70 years were divided into two groups of twenty-one and dosed with either 800 mg/day or 2000 mg/day of Alphastat® (Mytosterone(™ for fourteen days. Blood samples were collected on days 0, 3, 7 and 14 and assayed for T, DHT and ES. Body weight and blood pressure data were collected prior to blood collection. One-way, repeated measures analysis of variance (ANOVA-RM was performed at a significance level of alpha = 0.05 to determine differences from baseline within each group. Two-way analysis of variance (ANOVA-2 was performed after baseline subtraction, at a significance level of alpha = 0.05 to determine differences between dose groups. Results are expressed as means ± SEM. Results ANOVA-RM showed significant within group increases in serum total T and significant decreases in serum DHT from baseline in both dose groups at a significance level of alpha = 0.05. Significant decreases in serum ES are reported for the 2000

  8. Sub-therapeutic doses of fluvastatin and valsartan are more effective than therapeutic doses in providing beneficial cardiovascular pleiotropic effects in rats: A proof of concept study.

    Science.gov (United States)

    Janić, Miodrag; Lunder, Mojca; France Štiglic, Alenka; Jerin, Aleš; Skitek, Milan; Černe, Darko; Marc, Janja; Drevenšek, Gorazd; Šabovič, Mišo

    2017-12-01

    Statins and sartans can, in therapeutic doses, induce pleiotropic cardiovascular effects. Similar has recently been shown also for sub-therapeutic doses. We thus explored and compared the cardiovascular pleiotropic efficacy of sub-therapeutic vs. therapeutic doses. Wistar rats were randomly divided into 7 groups receiving fluvastatin, valsartan and their combination in sub-therapeutic and therapeutic doses, or saline. After 6weeks, the animals were euthanised, their hearts and thoracic aortas isolated, and blood samples taken. Endothelium-dependent relaxation of the thoracic aortae and ischaemic-reperfusion injury of the isolated hearts were assessed along with the related serum parameters and genes expression. Fluvastatin and valsartan alone or in combination were significantly more effective in sub-therapeutic than therapeutic doses. The sub-therapeutic combination greatly increased thoracic aorta endothelium-dependent relaxation and maximally protected the isolated hearts against ischaemia-reperfusion injury and was thus most effective. Beneficial effects were accompanied by increased levels of nitric oxide (NO) and decreased levels of asymmetric dimethylarginine (ADMA) in the serum (again prominently induced by the sub-therapeutic combination). Furthermore, nitric oxide synthase 3 (NOS3) and endothelin receptor type A (EDNRA) genes expression increased, but only in both combination groups and without significant differences between them. In the therapeutic dose groups, fluvastatin and valsartan decreased cholesterol values and systolic blood pressure. Sub-therapeutic doses of fluvastatin and valsartan are more effective in expressing cardiovascular pleiotropic effects than therapeutic doses of fluvastatin and/or valsartan. These results could be of significant clinical relevance. Copyright © 2017 Elsevier Inc. All rights reserved.

  9. Problems linked to effects of ionizing radiations low doses

    International Nuclear Information System (INIS)

    Anon.

    1995-10-01

    The question of exposure to ionizing radiations low doses and risks existing for professional and populations has been asked again, with the recommendations of the International Commission of Radiation Protection (ICRP) to lower the previous standards and agreed as guides to organize radiation protection, by concerned countries and big international organisms. The sciences academy presents an analysis which concerned on epidemiological and dosimetric aspects in risk estimation, on cellular and molecular aspects of response mechanism to irradiation. The observation of absence of carcinogen effects for doses inferior to 200 milli-sieverts and a re-evaluation of data coming from Nagasaki and Hiroshima, lead to revise the methodology of studies to pursue, to appreciate more exactly the effects of low doses, in taking in part, particularly, the dose rate. The progress of molecular and cellular biology showed that the extrapolation from high doses to low doses is not in accordance with actual data. The acknowledge of DNA repair and carcinogenesis should make clearer the debate. (N.C.). 61 refs., 9 annexes

  10. Low-dose effects hypothesis and observations on NPP personal

    Energy Technology Data Exchange (ETDEWEB)

    Georgieva, R.; Acheva, A.; Boteva, R.; Chobanova, N.; Djounova, J.; Gyuleva, I.; Ivanova, K.; Kurchatova, G.; Milchev, A.; Negoicheva, K.; Nikolov, V.; Panova, D.; Pejankov, I.; Rupova, I.; Stankova, K.; Zacharieva, E. [Radiobiology Department, National Centre of Radiobiology and Radiation Protection, Sofia (Bulgaria)

    2013-07-01

    In the modern world the use of various sources of ionizing radiation is nearly ubiquitous. They have numerous applications in industry, medicine, science, agriculture, etc. Radiation doses to workers nevertheless are commensurable to the natural background exposure. Published data on the health effects of occupational radiation exposure are often contradictory. Addressing the issue of „negative” (bystander effects, genomic instability) and „positive” (adaptive response, radiation hormesis) effects of low doses is important and has a significant social and economic impact. In this paper we summarize the results of our extensive monitoring of nuclear power plant (NPP) staff. We believe it is a cohort suitable for analysis of health effects at low doses, because of their good medical and dosimetric control. Our results rather support the idea of absence of adverse health effects in NPP workers. (author)

  11. Annual effective dose of 210Po from sea food origin (Oysters and Mussels) in Korea

    International Nuclear Information System (INIS)

    Cho, Bo Eum; Hong, Gi Hoon; Kim, Suk Hyun; Lee, Hyun Mi

    2016-01-01

    Ingestion of 210 Po laden seafood accounts for a substantial amount of the effective dose of 210 Po. Among seafood items, mollusks, especially domestically produced oysters and mussels, are highly enriched in 210 Po and are consumed in large quantities in Korea. Oysters and mussels around the Korean coasts were collected from major farm areas in November 2013. Samples were spiked with an aliquot of 210 Po as a yield tracer, and they were digested with 6 mol·L -1 HNO 3 and H 2 O 2 . The 210 Po and 209 Po were spontaneously deposited onto a silver disc in an acidic solution of 0.5 mol·L -1 HCl and measured using an alpha spectrometer. The activity concentrations of 210 Pb and 210 Po were decay corrected to the sampling date, accounting for the possible in-growth and decay of 210 Po. 210 Po activity concentrations in oysters were in a range from 41.3 to 206 Bq·(kg-ww -1 and mussels in a range from 42.9 to 46.7 Bq·(kg-ww) -1 . The 210 Po activity concentration of oysters in the turbid Western coast was higher than the Southern coast. The 210 Po activity concentration of the oysters was positively correlated (R2=0.89) with those of the suspended particulate matter in the surface water. The calculated annual effective dose of 210 Po from oysters and mussels consumed by the Korean population was 21-104 and 5.01-5.46 μSv·y -1 . The combined effective dose due to the consumption of oysters and mussels appears to account for about 35±19% of that arising from seafood consumption in the Korean population. The annual effective dose of 210 Po for oysters in the Korean population was found to be higher than other countries. The total annual effective dose of 210Po 210 Po due to consumption of oysters and mussels consumed in Korea was found to be 76±42 μSv·y -1 , accounting for 28±16% of the total effective dose of 210 Po from food in Korea

  12. Effective dose estimation in whole-body multislice CT in paediatric trauma patients

    Energy Technology Data Exchange (ETDEWEB)

    Munk, Robin D.; Saueressig, Ulrich; Kotter, Elmar; Langer, Mathias; Bley, Thorsten A. [University Hospital, Department of Radiology, Freiburg im Breisgau (Germany); Strohm, Peter C.; Zwingmann, Joern; Suedkamp, Norbert P. [University Hospital, Department of Orthopaedic and Trauma Surgery, Freiburg im Breisgau (Germany); Uhl, Markus [University Hospital, Department of Radiology, Section of Paediatric Radiology, Freiburg im Breisgau (Germany)

    2009-03-15

    The number of multislice CT (MSCT) scans performed in polytraumatized children has increased rapidly. There is growing concern regarding the radiation dose in MSCT and its long-term consequences, especially in children. To determine the effective dose to polytraumatized children who undergo whole-body MSCT. A total of 51 traumatized children aged 0-16 years underwent a polytrauma protocol CT scan between November 2004 and August 2006 at our institution. The effective dose was calculated retrospectively by a computer program (CT-Expo 1.5, Hannover, Germany). The mean effective dose was 20.8 mSv (range 8.6-48.9 mSv, SD{+-}7.9 mSv). There was no statistically significant difference in the effective dose between male and female patients. Whole-body MSCT is a superior diagnostic tool in polytraumatized children with 20.8 mSv per patient being a justified mean effective dose. In a potentially life-threatening situation whole-body MSCT provides the clinicians with relevant information to initiate life-saving therapy. Radiologists should use special paediatric protocols that include dose-saving mechanisms to keep the effective dose as low as possible. Further studies are needed to examine and advance dose-saving strategies in MSCT, especially in children. (orig.)

  13. Dose-effect relationship for cataract induction after single-dose total body irradiation and bone marrow transplantation for acute leukemia

    International Nuclear Information System (INIS)

    Kempen-Harteveld, M. Loes van; Belkacemi, Yazid; Kal, Henk B.; Labopin, Myriam; Frassoni, Francesco

    2002-01-01

    Purpose: To determine a dose-effect relationship for cataract induction, the tissue-specific parameter, α/β, and the rate of repair of sublethal damage, μ value, in the linear-quadratic formula have to be known. To obtain these parameters for the human eye lens, a large series of patients treated with different doses and dose rates is required. The data of patients with acute leukemia treated with single-dose total body irradiation (STBI) and bone marrow transplantation (BMT) collected by the European Group for Blood and Marrow Transplantation were analyzed. Methods and Materials: The data of 495 patients who underwent BMT for acute leukemia, who had STBI as part of their conditioning regimen, were analyzed using the linear-quadratic concept. The end point was the incidence of cataract formation after BMT. Of the analyzed patients, 175 were registered as having cataracts. Biologic effective doses (BEDs) for different sets of values for α/β and μ were calculated for each patient. With Cox regression analysis, using the overall chi-square test as the parameter evaluating the goodness of fit, α/β and μ values were found. Risk factors for cataract induction were the BED of the applied TBI regimen, allogeneic BMT, steroid therapy for >14 weeks, and heparin administration. To avoid the influence of steroid therapy and heparin on cataract induction, patients who received steroid or heparin treatment were excluded, leaving only the BED as a risk factor. Next, the most likely set of α/β and μ values was obtained. With this set, the cataract-free survival rates were calculated for specific BED intervals, according to the Kaplan-Meier method. From these calculations, cataract incidences were obtained as function of the BED at 120 months after STBI. Results: The use of BED instead of the TBI dose enabled the incidence of cataract formation to be predicted in a reasonably consistent way. With Cox regression analysis for all STBI data, a maximal chi-square value was

  14. Occupational radiation doses in Portugal from 1994 to 1998

    International Nuclear Information System (INIS)

    Alves, J.G.; Martins, M.B.; Amaral, E.M.

    2000-01-01

    This work reports on the occupational radiation doses for external radiation received in 1994-1998 by the radiation workers monitored by the Radiological Protection and Nuclear Safety Department (DPRSN) in Portugal. Individual monitoring for external radiation is carried out in Portugal by DPRSN since the 60s, and the workers are monitored on a monthly or quarterly bases. In 1995 DPRSN monitored approximately 8000 people and was the only laboratory carrying out this sort of activity in Portugal. In 1998 the number of monitored people increased to nearly 8500 from 860 facilities, which leads us to state that the results shown in this work are well representative of the universe of radiation workers in Portugal. Until 1996, the dose measurement procedure was based only on film dosimetry and the results reported for the 1994-1995 period were obtained with this methodology. Since 1996, thermoluminescent dosimetry (TLD) was gradually introduced and since then an effort has been made to transfer the monitored workers from film to TLD. In 1998, both film and TLD dosimetry systems were running simultaneously, with average numbers of 4500 workers monitored with film dosimetry, while 4000 were monitored with TLD. The data presented from 1996 to 1998 were obtained with both methodologies. This work reports the annual mean effective doses received from external radiation, for the monitored and exposed workers in the different fields of activity, namely, industry, research laboratories, health and mining. The distribution of the annual effective dose by dose intervals is also reported. The collective annual dose by field of activity is estimated and the contribution to the total annual collective dose is determined. The collective dose estimates for the period 1994 to 1998 demonstrated that the health sector is the most representative exposed group in Portugal. (author)

  15. Dose and dose rate effects of whole-body gamma-irradiation: II. Hematological variables and cytokines

    Science.gov (United States)

    Gridley, D. S.; Pecaut, M. J.; Miller, G. M.; Moyers, M. F.; Nelson, G. A.

    2001-01-01

    The goal of part II of this study was to evaluate the effects of gamma-radiation on circulating blood cells, functional characteristics of splenocytes, and cytokine expression after whole-body irradiation at varying total doses and at low- and high-dose-rates (LDR, HDR). Young adult C57BL/6 mice (n = 75) were irradiated with either 1 cGy/min or 80 cGy/min photons from a 60Co source to cumulative doses of 0.5, 1.5, and 3.0 Gy. The animals were euthanized at 4 days post-exposure for in vitro assays. Significant dose- (but not dose-rate-) dependent decreases were observed in erythrocyte and blood leukocyte counts, hemoglobin, hematocrit, lipopolysaccharide (LPS)-induced 3H-thymidine incorporation, and interleukin-2 (IL-2) secretion by activated spleen cells when compared to sham-irradiated controls (p factor-beta 1 (TGF-beta 1) and splenocyte secretion of tumor necrosis factor-alpha (TNF-alpha) were not affected by either the dose or dose rate of radiation. The data demonstrate that the responses of blood and spleen were largely dependent upon the total dose of radiation employed and that an 80-fold difference in the dose rate was not a significant factor in the great majority of measurements.

  16. The effects of low dose radiation (LDR) on mice of immune function

    International Nuclear Information System (INIS)

    Feng Li; Deng Daping

    2007-01-01

    Objective: To find out the Effects of Low Dose Radiation(LDR) on mice of immune function. Methods: Through flow cytometry to observe and analyse the effects of the leukomonocyte. Through immunohistochemistry to study IL-2, TNF-α. Results: At dose of 100mGy the stimulative effect on CD 4 + cells, CD 8 + cells and NK activity was higher than that at other doses. At dose of 500mGy leukomonocyte activity was lower. At dose of 100mGy, the colorations about IL-2, TNF-α deepen. Conclusion: LDR could stimulate immune function, especially at dose of 100mGy. while at dose of 500mGy, radiation could restrain the leukomonocyte activity. (authors)

  17. Individual dose monitoring of occupational exposure in nuclear industry system (1991-2000)

    International Nuclear Information System (INIS)

    Yang Lianzhen; Ma Jizeng; Li Taosheng

    2005-01-01

    The summary and main results of individual dose monitoring (1990-2000) from occupational exposure in China Nuclear Industry System are presented in this paper. During ten years, the external collective effective dose to workers in seven plants (not uranium mines and processing mills) and institutes is 98.48 person ·Sv, the per capita effective dose is 1.97 mSv. The general situation for individual dose monitoring from internal exposure is also introduced. The annual average committed effective dose is less than 5.0 mSv. The individual dose monitoring results (1991-1992) for occupational exposure from Uranium mines and processing mills are depicted. In the end, the individual dose monitoring data in nuclear industry system are preliminarily analysed. (authors)

  18. Patient dose assessment in different diagnostic procedures in nuclear medicine

    International Nuclear Information System (INIS)

    Sena, E. de; Bejar, M.J.; Berenguer, R.; Ruano, R.; Tamayo, P.

    2001-01-01

    Effective doses have been estimated for 314 patients under diagnostic procedures in a Nuclear Medicine Department using data reported in ICRP-80 and RIDIC (Radiation Internal Dose Information Center). Data on administered activity, radiopharmaceutical and administration route, age and sex of the patients have been collected. Doses in the most exposed critical organ for every protocol, doses in uterus, doses in fetus versus the stage of pregnancy (in case the female patient was pregnant) and doses for nursing infants have been also estimated. Ga-67 studies give the highest effective doses per protocol followed by cardiac SPECT procedures using Tl-201 chloride. Ga-67 studies also give the highest absorbed doses in uterus. Due to not administering different activities, depending on height and weight of adults, women receive doses about 20% higher than men. This would be a practice to modify in the future in order to optimise doses. (author)

  19. Patient dose assessment in different diagnostic procedures in nuclear medicine

    Energy Technology Data Exchange (ETDEWEB)

    Sena, E de; Bejar, M J; Berenguer, R [Servicio de Radiofisica y Proteccion Radiologica, Salamanca (Spain); Ruano, R; Tamayo, P [Servicio de Medicina Nuclear, Hospital Universitario de Salamanca (Spain)

    2001-03-01

    Effective doses have been estimated for 314 patients under diagnostic procedures in a Nuclear Medicine Department using data reported in ICRP-80 and RIDIC (Radiation Internal Dose Information Center). Data on administered activity, radiopharmaceutical and administration route, age and sex of the patients have been collected. Doses in the most exposed critical organ for every protocol, doses in uterus, doses in fetus versus the stage of pregnancy (in case the female patient was pregnant) and doses for nursing infants have been also estimated. Ga-67 studies give the highest effective doses per protocol followed by cardiac SPECT procedures using Tl-201 chloride. Ga-67 studies also give the highest absorbed doses in uterus. Due to not administering different activities, depending on height and weight of adults, women receive doses about 20% higher than men. This would be a practice to modify in the future in order to optimise doses. (author)

  20. Effects of low priming dose irradiation on cell cycle arrest of HepG2 cells caused by high dose irradiation

    International Nuclear Information System (INIS)

    Xia Jingguang; Jin Xiaodong; Chinese Academy of Sciences, Beijing; Li Wenjian; Wang Jufang; Guo Chuanling; Gao Qingxiang

    2005-01-01

    Human hepatoma cells hepG2 were irradiated twice by 60 Co γ-rays with a priming dose of 5 cGy and a higher dose of 3 Gy performed 4h or 8h after the low dose irradiation. Effects of the priming dose irradiation on cell cycle arrest caused by high dose were examined with flow cytometry. Cells in G 2 /M phase accumulated temporarily after the 5 cGy irradiation, and proliferation of tumor cells was promoted significantly by the low dose irradiation. After the 3 Gy irradiation, G 2 phase arrest occurred, and S phase delayed temporally. In comparison with 3 kGy irradiation only, the priming dose delivered 4h prior to the high dose irradiation facilitated accumulation of hepG2 cells in G 2 /M phase, whereas the priming dose delivered 8h prior to the high dose irradiation helped the cells to overcome G 2 arrest. It was concluded that effects of the priming dose treatment on cell cycle arrest caused by high dose irradiation were dependent on time interval between the two irradiations. (authors)

  1. Building shielding effects on radiation doses from routine radionuclide releases

    International Nuclear Information System (INIS)

    Kocher, D.C.

    1977-01-01

    In calculating population doses from the release of radionuclides to the atmosphere, it is usually assumed that man spends all of his time outdoors standing on a smooth infinite plane. Realistically, however, man spends most of the time indoors, so that substantial reductions in radiation doses may result compared with the usual estimates. Calculational models were developed to study the effects of building structures on radiation doses from routine releases of radionuclides to the atmosphere. Both internal dose from inhaled radionuclides and external photon dose from airborne and surface-deposited radionuclides are considered. The effect of building structures is described quantitatively by a dose reduction factor, which is the ratio of the dose inside a structure to the corresponding dose with no structure present. The internal dose from inhaled radionuclides is proportional to the radionuclide concentration in the air. Assuming that the outdoor airborne concentration is constant with time, the time-dependence of the indoor airborne concentration in terms of the structure air ventilation rate, the deposition velocities for radionuclides on the inside floor, walls, and ceiling, and the radioactive decay constant, were calculated

  2. Effective dose rate coefficients for exposure to contaminated soil

    Energy Technology Data Exchange (ETDEWEB)

    Veinot, K.G. [Easterly Scientific, Knoxville, TN (United States); Y-12 National Security Complex, Oak Ridge, TN (United States); Eckerman, K.F.; Easterly, C.E. [Easterly Scientific, Knoxville, TN (United States); Bellamy, M.B.; Hiller, M.M.; Dewji, S.A. [Oak Ridge National Laboratory, Center for Radiation Protection Knowledge, Oak Ridge, TN (United States); Hertel, N.E. [Oak Ridge National Laboratory, Center for Radiation Protection Knowledge, Oak Ridge, TN (United States); Georgia Institute of Technology, Atlanta, GA (United States); Manger, R. [University of California San Diego, Department of Radiation Medicine and Applied Sciences, La Jolla, CA (United States)

    2017-08-15

    The Oak Ridge National Laboratory Center for Radiation Protection Knowledge has undertaken calculations related to various environmental exposure scenarios. A previous paper reported the results for submersion in radioactive air and immersion in water using age-specific mathematical phantoms. This paper presents age-specific effective dose rate coefficients derived using stylized mathematical phantoms for exposure to contaminated soils. Dose rate coefficients for photon, electron, and positrons of discrete energies were calculated and folded with emissions of 1252 radionuclides addressed in ICRP Publication 107 to determine equivalent and effective dose rate coefficients. The MCNP6 radiation transport code was used for organ dose rate calculations for photons and the contribution of electrons to skin dose rate was derived using point-kernels. Bremsstrahlung and annihilation photons of positron emission were evaluated as discrete photons. The coefficients calculated in this work compare favorably to those reported in the US Federal Guidance Report 12 as well as by other authors who employed voxel phantoms for similar exposure scenarios. (orig.)

  3. Patient doses in interventional cardiology procedures

    International Nuclear Information System (INIS)

    Domienik, J.; Papierz, S.; Jankowski, J.; Peruga, J.Z.

    2008-01-01

    In most countries of European Union legislation requires the determination of the total skin dose to patient resulting from interventional procedures to assess the risk of deterministic effect. To this end, various dose indicators like dose area product (DAP), cumulative dose (CD) and entrance dose at the patient plane (EFD) are used in clinical practice. The study aims at relating those dose indicators with doses ascribe to the most irradiated areas of the patient skin usually expressed in terms of local maximal skin dose (MSD). For the study the local MSD and related to their areas are investigated and compared for coronary angiography CA and intervention (PCI). Two methods implying radiographic films Kodak EDR2 and matrixes of thermoluminescent dosimeters (TLDs) are applied for direct measurements of dose distribution for selected procedures. Both methods are compared. Additionally, for patient dosimetry the following data: MSD, CD, EFD, fluoroscopy time (FT), number of acquired images, total DAP, fluoro-DAP and record-DAP were collected for randomly selected procedure. The statistical quantities like: median, 3 rd quartile, mean and standard deviation for all dosimetric parameters are determined. Preliminary study showed that the values of data collected for coronary procedures are in the ranges 0,7 - 27,3 min for fluoroscopy time, 50 - 350 Gy cm 2 for total DAP, 300 - 2000 mGy for CD, 140 - 2000 mGy for EFD and 100 - 1500 mGy for local maximal skin dose. For interventions the ranges are, accordingly 3,0 - 43,6 min , 25 - 450 Gy cm 2 , 270 - 6600 mGy, 80 - 2600 mGy and 80 - 1500 mGy. As a result of the study the correlations between dose indicators and local MSD are analyzed. The concentration of dose on irradiated films are going to be investigated in some detail as well. (author)

  4. Absorbed and effective dose from periapical radiography by portable intraoral x-ray machine

    International Nuclear Information System (INIS)

    Cho, Jeong Yeon; Han, Won Jeong; Kim, Eun Kyung

    2007-01-01

    The purpose of this study was to measure the absorbed dose and to calculate the effective dose for periapical radiography done by portable intraoral x-ray machines. 14 full mouth, upper posterior and lower posterior periapical radiographs were taken by wall-type 1 and portable type 3 intraoral x-ray machines. Thermoluminescent dosemeters were placed at 23 sites at the layers of the tissue-equivalent ART woman phantom for dosimetry. Average tissue absorbed dose and radiation weighted dose were calculated for each major anatomical site. Effective dose was calculated using 2005 ICRP tissue weighted factors. On 14 full mouth periapical radiographs, the effective dose for wall-type x-ray machine was 30 Sv; for portable x-ray machines were 30 Sv, 22 Sv, 36 Sv. On upper posterior radiograph, the effective dose for wall-type x-ray machine was 4 Sv; for portable x-ray machines doses were 4 Sv, 3 Sv, 5 Sv. On lower posterior radiograph, the effective dose for wall type x-ray machine was 5 Sv; for portable x-ray machines doses were 4 Sv, 4 Sv, 5 Sv. Effective doses for periapical radiographs performed by portable intraoral x-ray machines were similar to doses for periapical radiographs taken by wall type intraoral x-ray machines

  5. Errors and Uncertainties in Dose Reconstruction for Radiation Effects Research

    Energy Technology Data Exchange (ETDEWEB)

    Strom, Daniel J.

    2008-04-14

    Dose reconstruction for studies of the health effects of ionizing radiation have been carried out for many decades. Major studies have included Japanese bomb survivors, atomic veterans, downwinders of the Nevada Test Site and Hanford, underground uranium miners, and populations of nuclear workers. For such studies to be credible, significant effort must be put into applying the best science to reconstructing unbiased absorbed doses to tissues and organs as a function of time. In many cases, more and more sophisticated dose reconstruction methods have been developed as studies progressed. For the example of the Japanese bomb survivors, the dose surrogate “distance from the hypocenter” was replaced by slant range, and then by TD65 doses, DS86 doses, and more recently DS02 doses. Over the years, it has become increasingly clear that an equal level of effort must be expended on the quantitative assessment of uncertainty in such doses, and to reducing and managing uncertainty. In this context, this paper reviews difficulties in terminology, explores the nature of Berkson and classical uncertainties in dose reconstruction through examples, and proposes a path forward for Joint Coordinating Committee for Radiation Effects Research (JCCRER) Project 2.4 that requires a reasonably small level of effort for DOSES-2008.

  6. Development of Real-Time Measurement of Effective Dose for High Dose Rate Neutron Fields

    International Nuclear Information System (INIS)

    Braby, L. A.; Reece, W. D.; Hsu, W. H.

    2003-01-01

    Studies of the effects of low doses of ionizing radiation require sources of radiation which are well characterized in terms of the dose and the quality of the radiation. One of the best measures of the quality of neutron irradiation is the dose mean lineal energy. At very low dose rates this can be determined by measuring individual energy deposition events, and calculating the dose mean of the event size. However, at the dose rates that are normally required for biology experiments, the individual events can not be separated by radiation detectors. However, the total energy deposited in a specified time interval can be measured. This total energy has a random variation which depends on the size of the individual events, so the dose mean lineal energy can be calculated from the variance of repeated measurements of the energy deposited in a fixed time. We have developed a specialized charge integration circuit for the measurement of the charge produced in a small ion chamber in typical neutron irradiation experiments. We have also developed 4.3 mm diameter ion chambers with both tissue equivalent and carbon walls for the purpose of measuring dose mean lineal energy due to all radiations and due to all radiations except neutrons, respectively. By adjusting the gas pressure in the ion chamber, it can be made to simulate tissue volumes from a few nanometers to a few millimeters in diameter. The charge is integrated for 0.1 seconds, and the resulting pulse height is recorded by a multi channel analyzer. The system has been used in a variety of photon and neutron radiation fields, and measured values of dose and dose mean lineal energy are consistent with values extrapolated from measurements made by other techniques at much lower dose rates. It is expected that this technique will prove to be much more reliable than extrapolations from measurements made at low dose rates because these low dose rate exposures generally do not accurately reproduce the attenuation and

  7. Dose-Effect Relationship in Chemoradiotherapy for Locally Advanced Rectal Cancer

    DEFF Research Database (Denmark)

    Jakobsen, Anders; Ploen, John; Vuong, Té

    2012-01-01

    PURPOSE: Locally advanced rectal cancer represents a major therapeutic challenge. Preoperative chemoradiation therapy is considered standard, but little is known about the dose-effect relationship. The present study represents a dose-escalation phase III trial comparing 2 doses of radiation...

  8. Dose-rate effects for apoptosis and micronucleus formation in gamma-irradiated human lymphocytes

    International Nuclear Information System (INIS)

    Boreham, D.R.; Dolling, J.-A.; Maves, S.R.; Siwarungsun, N.; Mitchel, R.E.J.

    2000-01-01

    We have compared dose-rate effects for γ-radiation-induced apoptosis and micronucleus formation in human lymphocytes. Long-term assessment of individual radiation-induced apoptosis showed little intraindividual variation but significant interindividual variation. The effectiveness of radiation exposure to cause apoptosis or micronucleus formation was reduced by low-dose-rate exposures, but the reduction was apparent at different dose rates for these two end points. Micronucleus formation showed a dose-rate effect when the dose rate was lowered to 0.29 cGy/min, but there was no accompanying cell cycle delay. A further increase in the dose-rate effect was seen at 0.15 cGy/min, but was now accompanied by cell cycle delay. There was no dose-rate effect for the induction of apoptosis until the dose rate was reduced to 0.15 cGy/min, indicating that the mechanisms or signals for processing radiation-induced lesions for these two end points must be different at least in part. There appear to be two mechanisms that contribute to the dose-rate effect for micronucleus formation. One of these does not affect binucleate cell frequency and occurs at dose rates higher than that required to produce a dose-rate effect for apoptosis, and one affects binucleate cell frequency, induced only at the very low dose rate which coincidentally produces a dose-rate effect for apoptosis. Since the dose rate at which cells showed reduced apoptosis as well as a further reduction in micronucleus formation was very low, we conclude that the processing of the radiation-induced lesions that induce apoptosis, and some micronuclei, is very slow in quiescent and PHA-stimulated lymphocytes, respectively. (author)

  9. Dose-rate effects for apoptosis and micronucleus formation in gamma-irradiated human lymphocytes

    Energy Technology Data Exchange (ETDEWEB)

    Boreham, D.R.; Dolling, J.-A.; Maves, S.R. [Atomic Energy of Canada Limited, Chalk River, Ontario (Canada); Siwarungsun, N. [Chulalongkorn Univ., Bangkok (Thailand); Mitchel, R.E.J. [Atomic Energy of Canada Limited, Chalk River, Ontario (Canada)

    2000-07-01

    We have compared dose-rate effects for {gamma}-radiation-induced apoptosis and micronucleus formation in human lymphocytes. Long-term assessment of individual radiation-induced apoptosis showed little intraindividual variation but significant interindividual variation. The effectiveness of radiation exposure to cause apoptosis or micronucleus formation was reduced by low-dose-rate exposures, but the reduction was apparent at different dose rates for these two end points. Micronucleus formation showed a dose-rate effect when the dose rate was lowered to 0.29 cGy/min, but there was no accompanying cell cycle delay. A further increase in the dose-rate effect was seen at 0.15 cGy/min, but was now accompanied by cell cycle delay. There was no dose-rate effect for the induction of apoptosis until the dose rate was reduced to 0.15 cGy/min, indicating that the mechanisms or signals for processing radiation-induced lesions for these two end points must be different at least in part. There appear to be two mechanisms that contribute to the dose-rate effect for micronucleus formation. One of these does not affect binucleate cell frequency and occurs at dose rates higher than that required to produce a dose-rate effect for apoptosis, and one affects binucleate cell frequency, induced only at the very low dose rate which coincidentally produces a dose-rate effect for apoptosis. Since the dose rate at which cells showed reduced apoptosis as well as a further reduction in micronucleus formation was very low, we conclude that the processing of the radiation-induced lesions that induce apoptosis, and some micronuclei, is very slow in quiescent and PHA-stimulated lymphocytes, respectively. (author)

  10. Radiation exposure during paediatric CT in Sudan: CT dose, organ and effective doses

    International Nuclear Information System (INIS)

    Suliman, I.I.; Khamis, H.M.; Ombada, T.H.; Alzimami, K.; Alkhorayef, M.; Sulieman, A.

    2015-01-01

    The purpose of this study was to assess the magnitude of radiation exposure during paediatric CT in Sudanese hospitals. Doses were determined from CT acquisition parameters using CT-Expo 2.1 dosimetry software. Doses were evaluated for three patient ages (0-1, 1-5 and 5-10 y) and two common procedures (head and abdomen). For children aged 0-1 y, volume CT air kerma index (C vol ), air Kerma-length product and effective dose (E) values were 19.1 mGy, 265 mGy.cm and 3.1 mSv, respectively, at head CT and those at abdominal CT were 8.8 mGy, 242 mGy.cm and 7.7 mSv, respectively. Those for children aged 1-5 y were 22.5 mGy, 305 mGy.cm and 1.1 mSv, respectively, at head CT and 12.6 mGy, 317 mGy.cm, and 5.1 mSv, respectively, at abdominal CT. Dose values and variations were comparable with those reported in the literature. Organ equivalent doses vary from 7.5 to 11.6 mSv for testes, from 9.0 to 10.0 mSv for ovaries and from 11.1 to 14.3 mSv for uterus in abdominal CT. The results are useful for dose optimisation and derivation of national diagnostic reference levels. (authors)

  11. Trend of collective dose and dose reduction measures of Mitsubishi Electric Corporation workers in nuclear power plants

    International Nuclear Information System (INIS)

    Yamato, I.; Nakayama, T.; Shimokawa, F.; Yamamoto, T.

    1996-01-01

    MELCO has supplied the reactor instrumentation control system, reactor coolant pump motors, turbine generator and central control system for the pressurized water type nuclear power plant. For the legal periodical inspection and repair work, MELCO has also received orders for the periodical inspection for 23 power plants (including 4 plants under construction) of 5 electric power companies, and executed the inspection work from the view point of preventive maintenance. The annual dose for MELCO's workers is liable to be decreased in spite of increased number of plants. The dose for new plant in particular is 50, or less as compared with that for conventional plant. This is because the measures taken for the conventional plant against the dose reduction is reflected upon the new plant. The dose reduction measures are taken for each system for which order was received. Such measures are mainly intended to improve the work procedures and equipment for reduction of work time in the radioactive area and to arrange the working process, so as to perform the work in such period when the dose level at the working environment is low. To enhance the workers' consciousness for reduction of dose, MELCO provided the workers with dose predictive training, and let them aware of such items known at the tool box briefing (TBX), which could realize the dose reduction for workers. MELCO has been positively promoting the activity to arrange the desirable work environment for extermination of 3Ks (giken, gitsui, titanai) or 3Ds (dangerous, difficult, dirty) including protection against radiation in corporation with electric power companies. (author)

  12. Effective dose to patient during cardiac interventional procedures (Prague workplaces)

    International Nuclear Information System (INIS)

    Stisova, V.

    2004-01-01

    The aim of this study was to assess effective dose to a patient during cardiac procedures, such as coronary angiography (CA) and percutaneous transluminal angioplasty (PTCA). Measurements were performed on 185 patients in four catheterisation laboratories in three hospitals in Prague using the dose area product (DAP) meter. Calculations of surface and effective dose were performed with Monte-Carlo-based program PCXMC. The mean DAP value per procedure determined in all workplaces ranged between 25.0 and 54.5 Gy cm 2 for CA and 43.0-104.5 Gy cm 2 for PTCA. In three cases, the surface dose exceeded the 2 Gy level for occurrence of transient erythema. The mean effective dose per procedure in an workplaces was determined to be in the range of 2.7-8.8 mSv for CA and 5.7-15.3 mSv for CA + PTCA combined. The results presented are comparable with those published by other authors. (authors)

  13. Biological UV-doses and the effect on an ozone layer depletion

    International Nuclear Information System (INIS)

    Dahlback, A.; Henriksen, T.

    1988-08-01

    Effective UV-doses were calculated based on the integrated product of the biological action spectrum and the solar radiation. The calculations included absorption and scattering of UV-radiation in the atmosphere, both for normal ozone conditions as well as for a depleted ozone layer. The effective annual UV-dose increases by approximately 4% per degree of latitude towards the equator. An ozone depletion of 1% increases the annual UV-dose by approximately 1% at 60 o N. A large depletion of 50% over Scandinavia (60 o N) would give this region an effective UV-dose similar to that obtained, with normal ozone conditions, at a latitude of 40 o N (California or the Mediterranean countries). The Antarctic ozone hole increases the annual UV-dose by 20 to 25% which is a similar increase as that attained by moving 5 to 6 degrees of latitude nearer the equator. The annual UV-dose on higher latitudes is mainly determined by the summer values of ozone. Both the ozone values and the effective UV-doses vary from one year to another (within ±4%). No positive or negative trend is observed for Scandinavia from 1978 to 1988

  14. Ameliorative effects of low dose/low dose-rate irradiation on reactive oxygen species-related diseases model mice

    International Nuclear Information System (INIS)

    Nomura, Takaharu

    2008-01-01

    Living organisms have developed complex biological system which protects themselves against environmental radiation, and irradiation with proper dose, dose-rate and irradiation time can stimulate their biological responses against oxidative stress evoked by the irradiation. Because reactive oxygen species are involved in various human diseases, non-toxic low dose/low dose-rate radiation can be utilized for the amelioration of such diseases. In this study, we used mouse experimental models for fatty liver, nephritis, diabetes, and ageing to elucidate the ameliorative effect of low dose/low dose-rate radiation in relation to endogenous antioxidant activity. Single irradiation at 0.5 Gy ameliorates carbon tetrachloride-induced fatty liver. The irradiation increases hepatic anti-oxidative system involving glutathione and glutathione peroxidase, suggesting that endogenous radical scavenger is essential for the ameliorative effect of low dose radiation on carbon tetrachloride-induced fatty liver. Single irradiation at 0.5 Gy ameliorates ferric nitrilotriacetate-induced nephritis. The irradiation increases catalase and decreases superoxide dismutase in kidney. The result suggests that low dose radiation reduced generation of hydroxide radical generation by reducing cellular hydroperoxide level. Single irradiation at 0.5 Gy at 12 week of age ameliorates incidence of type I diabetes in non-obese diabetic (NOD) mice through the suppression of inflammatory activity of splenocytes, and resultant apoptosis of β-cells in pancreas. The irradiation activities of superoxide dismutase and catalase, which coordinately diminish intracellular reactive oxygen species. Continuous irradiation at 0.70 mGy/hr from 10 week of age elongates life span, and suppresses alopecia in type II diabetesmice. The irradiation improved glucose clearance without affecting insulin-resistance, and increased pancreatic catalase activity. The results suggest that continuous low dose-rate irradiation protect

  15. 137Cs And 210Po Dose Assessment Due To Consumption Of Red Sea Coral Reef Fishes Collected From The Local Market (Sudan)

    International Nuclear Information System (INIS)

    Hassona, R. K.; Sam, A. K.; Sirelkhatim, D. A.; Osman, O. I.; Larosa, J.

    2004-01-01

    Assessment of Committed Effective Dose (CED) due to consumption of marine fishes (Red Sea area) was performed in 33 different marine fish samples collected from the local market at Port sudan and classified according to their feeding habits into three categories: carnivores, herbivores, and omnivores. Activity concentrations of 210 Po and 137 Cs were determined and were found to range between 0.25 to 6.42 (carnivores), 0.7-5 (omnivores) and 1.5-3.8 (herbivores) Bq/Kg fresh w. for 210 Po and 0.1 to 0.46 (carnivores), 0.09 to 0.35 (omnivores) and 0.09 to 0.3 (herbivores) Bq/Kg fresh w. For 137 Cs which are several times lower than those of 210 Po. Appropriate conversion factors were used to derive the CED which was found to be 0.012, 0.01 and 0.01 (μ Sv/y) in carnivores, omnivores and herbivores, respectively, for 137 Cs, this contributes about 0.4% of the total dose. While for 210 Po, it was found to be 3.47, 4.81 and 4.14 (μ Sv/y) in carnivores, omnivores and herbivores, respectively which represents 99.6% of the total dose. The results of CED suggest that the dose received by Sudanese population from the consumption of marine fishes is rather small and the contribution of 137 Cs is negligible compared to 210 Po. (Authors)

  16. Dose-effect relationships for the US radium dial painters

    International Nuclear Information System (INIS)

    Thomas, R.G.

    1995-01-01

    Dose-response data are presented from a large percentage of the US workers who were exposed to radium through the painting of luminous dials. The data in this paper are only from females, because very few males worked in this occupation. Log-normal analyses were done for radium-induced bone sarcomas and head carcinomas after the populations of the respective doses were first determined to be log-normally distributed. These populations included luminisers who expressed no radium-related cancerous condition. In this study of the female radium luminisers, the most important data concerning radiation protection are probably from workers who were exposed to radium but showed no cancer incidence. A total of 1391 subjects with average measured skeletal doses below 10 Gy are in this category. A primary purpose is to illustrate the strong case that 226,228 Ra is representative of those radionuclides that exemplify in humans a 'threshold' dose, a dose below which there has been no observed health effects on the exposed individual. Application of a threshold dose for radium deposited in the skeleton does not mean to imply that any other source of skeletal irradiation should be considered to follow a similar pattern. Second, a policy issue that begs for attention is the economic consequence of forcing radiation to appear as a highly toxic insult. It is time to evaluate the data objectively instead of formatting the extrapolation scheme beforehand and forcing the data to fit a preconceived pattern such as linearity through the dose-effect origin. In addition, it is time to re-evaluate (again) variations in background radiation levels throughout the world and to cease being concerned with, and regulating against, miniscule doses for which no biomedical effects on humans have ever been satisfactorily identified or quantified. (author)

  17. Determination of effective dose for workers hemodynamics service using double dosimetry

    International Nuclear Information System (INIS)

    Ruiz Lopez, M. A.; Lobato Munoz, M.; Jodar Lopez, C. A.; Ramirez Ros, J. C.; Jerez Sainz, M. I.; Pamos Urena, M.; Carrasco Rodriguez, J. L.

    2013-01-01

    The use of an additional dosimeter at the level of the neck above the lead apron we can provide an indication of the dose in the head (the Crystal dose). In addition, it is possible to combine the two readings of the dosimeter to provide an improved estimate of the effective dose. In the hemodynamics service of our Hospital we have maintained a worker for 3 years with the double dosimetry read monthly. With the readings from these dosimeters will do following algorithms, several estimates of the effective dose to see if, with working conditions that occur in this service, it would be necessary to extend this practice to the rest of the workers to get a better estimation of effective dose. (Author)

  18. Effects of low dose mitomycin C on experimental tumor radiotherapy

    International Nuclear Information System (INIS)

    Yang Jianzheng; Liang Shuo; Qu Yaqin; Pu Chunji; Zhang Haiying; Wu Zhenfeng; Wang Xianli

    2001-01-01

    Objective: To evaluate the possibility of low dose mitomycin C(MMC) as an adjunct therapy for radiotherapy. Methods: Change in tumor size tumor-bearing mice was measured. Radioimmunoassay was used to determine immune function of mice. Results: Low dose Mac's pretreatment reduced tumor size more markedly than did radiotherapy only. The immune function in mice given with low dose MMC 12h before radiotherapy was obviously higher than that in mice subjected to radiotherapy only (P<0.05), and was close to that in the tumor-bearing mice before radiotherapy. Conclusion: Low dose MMC could improve the radiotherapy effect. Pretreatment with low dose MMC could obviously improve the immune suppression state in mice caused by radiotherapy. The mechanism of its improvement of radiotherapeutic effect by low dose of MMC might be due to its enhancement of immune function and induction of adaptive response in tumor-bearing mice

  19. Dose received by radiation workers in Australia, 1991

    Energy Technology Data Exchange (ETDEWEB)

    Morris, N D

    1994-07-01

    Exposure to radiation can cause genetic defects or cancer. People who use sources of radiation as part of their employment are potentially at a greater risk than others owing to the possibility of their being continually exposed to small radiation doses over a long period. In Australia, the National Health and Medical Research Council has established radiation protection standards and set annual effective dose limits for radiation workers in order to minimise the chance of adverse effects occurring. These standards are based on the the recommendations of the International Commission on Radiological Protection (ICRP 1990). In order to ensure that the prescribed limits are not exceeded and to ensure that doses are kept to a minimum, some sort of monitoring is necessary. The primary purpose of this report is to provide data on the distribution of effective doses for different occupational categories of radiation worker in Australia. The total collective effective dose was found to be of the order of 4.9 Sv for a total of 34750 workers. 9 refs., 16 tabs., 6 figs.

  20. Dose received by radiation workers in Australia, 1991

    International Nuclear Information System (INIS)

    Morris, N.D.

    1994-07-01

    Exposure to radiation can cause genetic defects or cancer. People who use sources of radiation as part of their employment are potentially at a greater risk than others owing to the possibility of their being continually exposed to small radiation doses over a long period. In Australia, the National Health and Medical Research Council has established radiation protection standards and set annual effective dose limits for radiation workers in order to minimise the chance of adverse effects occurring. These standards are based on the the recommendations of the International Commission on Radiological Protection (ICRP 1990). In order to ensure that the prescribed limits are not exceeded and to ensure that doses are kept to a minimum, some sort of monitoring is necessary. The primary purpose of this report is to provide data on the distribution of effective doses for different occupational categories of radiation worker in Australia. The total collective effective dose was found to be of the order of 4.9 Sv for a total of 34750 workers. 9 refs., 16 tabs., 6 figs

  1. Choline PET based dose-painting in prostate cancer - Modelling of dose effects

    International Nuclear Information System (INIS)

    Niyazi, Maximilian; Bartenstein, Peter; Belka, Claus; Ganswindt, Ute

    2010-01-01

    Several randomized trials have documented the value of radiation dose escalation in patients with prostate cancer, especially in patients with intermediate risk profile. Up to now dose escalation is usually applied to the whole prostate. IMRT and related techniques currently allow for dose escalation in sub-volumes of the organ. However, the sensitivity of the imaging modality and the fact that small islands of cancer are often dispersed within the whole organ may limit these approaches with regard to a clear clinical benefit. In order to assess potential effects of a dose escalation in certain sub-volumes based on choline PET imaging a mathematical dose-response model was developed. Based on different assumptions for α/β, γ50, sensitivity and specificity of choline PET, the influence of the whole prostate and simultaneous integrated boost (SIB) dose on tumor control probability (TCP) was calculated. Based on the given heterogeneity of all potential variables certain representative permutations of the parameters were chosen and, subsequently, the influence on TCP was assessed. Using schedules with 74 Gy within the whole prostate and a SIB dose of 90 Gy the TCP increase ranged from 23.1% (high detection rate of choline PET, low whole prostate dose, high γ50/ASTRO definition for tumor control) to 1.4% TCP gain (low sensitivity of PET, high whole prostate dose, CN + 2 definition for tumor control) or even 0% in selected cases. The corresponding initial TCP values without integrated boost ranged from 67.3% to 100%. According to a large data set of intermediate-risk prostate cancer patients the resulting TCP gains ranged from 22.2% to 10.1% (ASTRO definition) or from 13.2% to 6.0% (CN + 2 definition). Although a simplified mathematical model was employed, the presented model allows for an estimation in how far given schedules are relevant for clinical practice. However, the benefit of a SIB based on choline PET seems less than intuitively expected. Only under the

  2. Effects of low dose radiation on tumor-bearing mice

    International Nuclear Information System (INIS)

    Feng Li; Hou Dianjun; Huang Shanying; Deng Daping; Wang Linchao; Cheng Yufeng

    2007-01-01

    Objective: To explore the effects of low-dose radiation on tumor-bearing mice and radiotherapy induced by low-dose radiation. Methods: Male Wistar mice were implanted with Walker-256 sarcoma cells in the right armpit. On day 4, the mice were given 75 mGy whole-body X-ray radiation. From the fifth day, tumor volume was measured, allowing for the creation of a graph depicting tumor growth. Lymphocytes activity in mice after whole-body X-ray radiation with LDR was determinned by FCM. Cytokines level were also determined by ELISA. Results: Compared with the radiotherapy group, tumor growth was significantly slower in the mice pre-exposed to low-dose radiation (P<0.05), after 15 days, the average tumor weight in the mice pre- exposed to low-dose radiation was also significantly lower (P<0.05). Lymphocytes activity and the expression of the CK in mice after whole-body y-ray radiation with LDR increased significantly. Conclusions: Low-dose radiation can markedly improve the immune function of the lymphocyte, inhibit the tumor growth, increase the resistant of the high-dose radiotherapy and enhance the effect of radiotherapy. (authors)

  3. Comments on 'Standard effective doses for proliferative tumours'

    International Nuclear Information System (INIS)

    Dasu, Iuliana Livia; Dasu, Alexandru; Denekamp, Juliana; Fowler, Jack F.

    2000-01-01

    We should like to make some comments on the paper published by Jones et al (1999). The paper presents some interesting and useful contributions on the theoretical evaluation of different fractionated schedules used now. The use of the linear quadratic equation has been very useful in focusing attention on the differences in fractionation responses of fast and slow proliferating normal tissues and tumours. Unfortunately the BED 10 or BED 3 units for (α/β ratios of 10 Gy and 3 Gy respectively) do not directly relate to anything used in routine clinical practice. The purpose of the paper by Jones et al (1999) is to covert any new schedule into the equivalent total dose as if it was given in the same size fractions as are in common use in that department. They illustrate that, if proliferation is taken into account for the altered schedule, it can be compared in two ways with the standard conventional schedule: (a) the proliferative standard effective dose one (PSED 1 ) in which the proliferation correction is applied in the altered schedule, but not in the standard schedule; (b) the proliferative standard effective dose two (PSED 2 ) in which the proliferation correction is applied to both schedules using the same proliferation parameters. This is expected to provide a better evaluation of the response of a 'real' tumour (i.e. a tumour that also proliferates during the standard treatment). However, there seem to be two errors in the paper. First, the authors quoted a wrong equation for calculating the proliferative standard effective dose two (PSED 2 ) (equations (2) and (A6) in their paper). There are also some special cases with respect to the time available for proliferation and the duration of the treatment that have been neglected in their paper and which require further specification. Therefore, we should like to give the full mathematical derivation of the correct equations for calculating the proliferative standard effective doses. We would also like to make

  4. Late effects of post-high-dose-rate brachytherapy for oropharyngeal carcinoma: are they severer than post-low-dose-rate?

    International Nuclear Information System (INIS)

    Nose, T.; Koizumi, M.; Nishiyama, K.; Peiffert, D.; Lapeyre, M.; Hoffstetter, S.

    2004-01-01

    Background: late effects by high-dose-rate (HDR) brachytherapy have been believed severer than low-dose-rate (LDR) provided tumor control was constant. Local control of oropharyngeal carcinoma with HDR at Osaka Medical Center was comparable to LDR series from Centre Alexis Vautrin (82%, 79.5%, respectively). To assess the feasibility of HDR brachytherapy, the late effects were compared. Patients and methods: the data of 29 HDR and 24 LDR patients (median follow-up of 27 and 29.5 months, respectively; p = 0.89) were collected. The HDR schedule was 21 Gy/3.5 fractions/2 days following 46 Gy/23 fractions external beam, while 25 Gy/3 days following 50 Gy/25 fractions external beam was for LDR. Late changes were evaluated using RTOG/EORTC late morbidity scoring scheme. For subclinical late changes, mucosa chapter of Dische score was modified for brachytherapy. Scores were discussed through photos and were agreed on by authors. Late sequelae were estimated, by reviewing charts, concerning frequency, severity, and duration of mucosal damages (erosion and ulcer). Results: Late changes were of no difference (p = 0.12 for EORTC/RTOG, and p = 0.45, 0.47, 1.00, 0.12, 0.16, 0.95, 0.27, 0.21 for erythema, ulceration, edema, thinning, pallor, telangiectasia, mobility impairment of tongue/faucial pillars, respectively, of the modified Dische score). Late sequelae showed no differences (p = 0.90, 0.12, 0.40 for frequency, severity, duration, respectively, of mucosal damages). Conclusion: the late effects by HDR were not severer than by LDR. HDR oropharyngeal brachytherapy is as safe as LDR. (orig.)

  5. Dose reduction at nuclear power plants

    International Nuclear Information System (INIS)

    Baum, J.W.; Dionne, B.J.

    1983-01-01

    The collective dose equivalent at nuclear power plants increased from 1250 rem in 1969 to nearly 54,000 rem in 1980. This rise is attributable primarily to an increase in nuclear generated power from 1289 MW-y to 29,155 MW-y; and secondly, to increased average plant age. However, considerable variation in exposure occurs from plant to plant depending on plant type, refueling, maintenance, etc. In order to understand the factors influencing these differences, an investigation was initiated to study dose-reduction techniques and effectiveness of as low as reasonably achievable (ALARA) planning at light water plants. Objectives are to: identify high-dose maintenance tasks and related dose-reduction techniques; investigate utilization of high-reliability, low-maintenance equipment; recommend improved radioactive waste handling equipment and procedures; examine incentives for dose reduction; and compile an ALARA handbook

  6. Analysis of radiation doses to patients from diagnostic department of nuclear medicine

    International Nuclear Information System (INIS)

    Lepej, L.; Messingerova, M.

    1995-01-01

    In this paper the values of mean effective dose equivalents per unit activity (H E/1Bq ) were used for the calculation of mean effective dose equivalents for one examination (H E ). The collective effective dose equivalents for each radiopharmaceutical and type of examination (S ER ) and global collective effective dose equivalent for department for all radiopharmaceuticals (S E ) during evaluated period were defined. The data for years from 1992 to 1994 were evaluated and compared with results in literature. The evaluation of radiation doses in nuclear medicine department is useful parameter for internal quality control. Using this method, the radiation dose in this laboratory was changed to minimum (under mean value of Slovak Republic). Unfortunately, the real data of patients radiation doses are different from the calculated one. Due to different kinetic of radiopharmaceuticals in individual patients (influenced by pathology, age, etc.) the evaluation of radiation burden to nuclear medicine patients is problematic. But this approach enable the relative comparison of the changes in values of H E and S E during the observed period. The evaluation of individual (minimal) effective dose equivalent - (H min ) which represents dose calculated under physiologic conditions can be useful for indication of diagnostic examination by physicians. Therefore the systematic registration of H min from all examinations - patient's radiation history. This is specially important in the case of children and young people. The importance of the proposed method, is in regulation of radiation dose from nuclear medicine diagnostic examinations, not only be the control of number and type of examinations, but also by selection of used radiopharmaceuticals and by the way how to use them. (J.K.) 1 fig., 2 refs

  7. Cumulative effective dose associated with radiography and CT of adolescents with spinal injuries.

    Science.gov (United States)

    Lemburg, Stefan P; Peters, Soeren A; Roggenland, Daniela; Nicolas, Volkmar; Heyer, Christoph M

    2010-12-01

    The purpose of this study was to analyze the quantity and distribution of cumulative effective doses in diagnostic imaging of adolescents with spinal injuries. At a level 1 trauma center from July 2003 through June 2009, imaging procedures during initial evaluation and hospitalization and after discharge of all patients 10-20 years old with spinal fractures were retrospectively analyzed. The cumulative effective doses for all imaging studies were calculated, and the doses to patients with spinal injuries who had multiple traumatic injuries were compared with the doses to patients with spinal injuries but without multiple injuries. The significance level was set at 5%. Imaging studies of 72 patients (32 with multiple injuries; average age, 17.5 years) entailed a median cumulative effective dose of 18.89 mSv. Patients with multiple injuries had a significantly higher total cumulative effective dose (29.70 versus 10.86 mSv, p cumulative effective dose to multiple injury patients during the initial evaluation (18.39 versus 2.83 mSv, p cumulative effective dose. Adolescents with spinal injuries receive a cumulative effective dose equal to that of adult trauma patients and nearly three times that of pediatric trauma patients. Areas of focus in lowering cumulative effective dose should be appropriate initial estimation of trauma severity and careful selection of CT scan parameters.

  8. Dose enhancement effects of X ray radiation in bipolar transistors

    International Nuclear Information System (INIS)

    Chen Panxun

    1997-01-01

    The author has presented behaviour degradation and dose enhancement effects of bipolar transistors in X ray irradiation environment. The relative dose enhancement factors of X ray radiation were measured in bipolar transistors by the experiment methods. The mechanism of bipolar device dose enhancement was investigated

  9. Adult and child doses in standardised X ray examinations

    International Nuclear Information System (INIS)

    Gallini, R.E.; Belletti, S.; Berna, V.; Giugni, U.

    1992-01-01

    Data are presented on patient doses measured during standard hospital routine in seven radiological departments in the Province of Brescia. This study is part of a Quality Assurance Programme, carried out to assess the possibility and validity of a regional protocol. Before collecting dose data, tests on the performance of the X ray units and processors were performed in every department according to a Quality Control Protocol. The following examinations were considered: chest, knee, lumbar spine, pelvis, skull and barium meal. The surface entrance doses of 314 adults and 216 children were measured. The sample size for barium meal was lower: 65 adults and only 10 children. The patients anthropometric data and the technical parameters used were collected at the same time. For adults the organ doses and effective dose equivalent (EDE) were calculated. A wide range of entrance doses were obtained both for adults and children. The reasons can be: patient size, performance of the equipment and processors, film-screen combination, use of AEC, use of fluoroscopy and grid, training and skill of the staff

  10. Adult and child doses in standardised X ray examinations

    International Nuclear Information System (INIS)

    Gallini, R.E.; Belletti, S.; Berna, V.; Giugni, U.

    1992-01-01

    Data are presented on patient doses measured during standard hospital routine in seven radiological departments in the Province of Brescia, as part of a Quality Assurance Programme, carried out to assess the possibility and validity of a regional protocol. Before collecting dose data, tests on the performance of the X ray units and processors were performed in every department according to a Quality Control Protocol. The following examinations were considered: chest, knee, lumbar spine, pelvis, skull and barium meal. Surface entrance doses of 314 adults and 216 children were measured. The sample size for barium meal was lower: 65 adults and 10 children. The patients anthropometric data and technical parameters used were collected at the same time. For adults the organ doses and effective dose equivalent (EDE) were calculated. A wide range of entrance doses were obtained both for adults and children, due to patient size, performance of the equipment and processors, film-screen combination, use of AEC, use of fluoroscopy and grid, training and skill of the staff. (author)

  11. Effective doses to patients undergoing thoracic computed tomography examinations.

    Science.gov (United States)

    Huda, W; Scalzetti, E M; Roskopf, M

    2000-05-01

    The purpose of this study was to investigate how x-ray technique factors and effective doses vary with patient size in chest CT examinations. Technique factors (kVp, mAs, section thickness, and number of sections) were recorded for 44 patients who underwent a routine chest CT examination. Patient weights were recorded together with dimensions and mean Hounsfield unit values obtained from representative axial CT images. The total mass of directly irradiated patient was modeled as a cylinder of water to permit the computation of the mean patient dose and total energy imparted for each chest CT examination. Computed values of energy imparted during the chest CT examination were converted into effective doses taking into account the patient weight. Patient weights ranged from 4.5 to 127 kg, and half the patients in this study were children under 18 years of age. All scans were performed at 120 kVp with a 1 s scan time. The selected tube current showed no correlation with patient weight (r2=0.06), indicating that chest CT examination protocols do not take into account for the size of the patient. Energy imparted increased with increasing patient weight, with values of energy imparted for 10 and 70 kg patients being 85 and 310 mJ, respectively. The effective dose showed an inverse correlation with increasing patient weight, however, with values of effective dose for 10 and 70 kg patients being 9.6 and 5.4 mSv, respectively. Current CT technique factors (kVp/mAs) used to perform chest CT examinations result in relatively high patient doses, which could be reduced by adjusting technique factors based on patient size.

  12. Effect of the European directive on medical exposure on patients doses

    Energy Technology Data Exchange (ETDEWEB)

    Wade, P.; Heaton, B. [Aberdeen Royal Infirmary, Aberdeen (United Kingdom)

    2006-07-01

    implemented, which will be described. Incidents often happen due to a sequence of events and are only identified by vigilant radiology staff. It has been found that hospital doctors are the group of referrers most likely to complete referrals wrongly which may result in the wrong patient being x-rayed. It is also surprising the number of parents who turn up for a child appointment. The selection and use of equipment is now more thoroughly scrutinized, with patient doses playing a more important role. We are encouraged to measure patient doses for common procedures on every x-ray set to develop local Diagnostic Reference Levels (D.R.L.s). Rooms with higher D.R.L.s are identified as a priority for replacement. Whilst the implementation of this Directive has definitely had some effect on identifying wrong referrals and optimising the doses patients receive. It is questionable that the Total Collective Dose for Medical Exposures will be reduced because of the increasing use of CT and PET where individual doses are much larger. This will be discussed further. Also the current vogue for CT being used in private practice for cancer and heart disease screening is likely to undo any dose benefits gained from this legislation. (authors)

  13. Effect of the European directive on medical exposure on patients doses

    International Nuclear Information System (INIS)

    Wade, P.; Heaton, B.

    2006-01-01

    , which will be described. Incidents often happen due to a sequence of events and are only identified by vigilant radiology staff. It has been found that hospital doctors are the group of referrers most likely to complete referrals wrongly which may result in the wrong patient being x-rayed. It is also surprising the number of parents who turn up for a child appointment. The selection and use of equipment is now more thoroughly scrutinized, with patient doses playing a more important role. We are encouraged to measure patient doses for common procedures on every x-ray set to develop local Diagnostic Reference Levels (D.R.L.s). Rooms with higher D.R.L.s are identified as a priority for replacement. Whilst the implementation of this Directive has definitely had some effect on identifying wrong referrals and optimising the doses patients receive. It is questionable that the Total Collective Dose for Medical Exposures will be reduced because of the increasing use of CT and PET where individual doses are much larger. This will be discussed further. Also the current vogue for CT being used in private practice for cancer and heart disease screening is likely to undo any dose benefits gained from this legislation. (authors)

  14. Study on the estimation of probabilistic effective dose. Committed effective dose from intake of marine products using Oceanic General Circulation Model

    International Nuclear Information System (INIS)

    Nakano, Masanao

    2007-01-01

    The worldwide environmental protection is required by the public. A long-term environmental assessment from nuclear fuel cycle facilities to the aquatic environment also becomes more important to utilize nuclear energy more efficiently. Evaluation of long-term risk including not only in Japan but also in neighboring countries is considered to be necessary in order to develop nuclear power industry. The author successfully simulated the distribution of radionuclides in seawater and seabed sediment produced by atmospheric nuclear tests using LAMER (Long-term Assessment ModEl for Radioactivity in the oceans). A part of the LAMER calculated the advection- diffusion-scavenging processes for radionuclides in the oceans and the Japan Sea in cooperate with Oceanic General Circulation Model (OGCM) and was validated. The author is challenging to calculate probabilistic effective dose suggested by ICRP from intake of marine products due to atmospheric nuclear tests using the Monte Carlo method in the other part of LAMER. Depending on the deviation of each parameter, the 95th percentile of the probabilistic effective dose was calculated about half of the 95th percentile of the deterministic effective dose in proforma calculation. The probabilistic assessment gives realistic value for the dose assessment of a nuclear fuel cycle facility. (author)

  15. Dose rate effect models for biological reaction to ionizing radiation in human cell lines

    International Nuclear Information System (INIS)

    Magae, Junji; Ogata, Hiromitsu

    2008-01-01

    Full text: Because of biological responses to ionizing radiation are dependent on irradiation time or dose rate as well as dose, simultaneous inclusion of dose and dose rate is required to evaluate the risk of long term irradiation at low dose rates. We previously published a novel statistical model for dose rate effect, modified exponential (MOE) model, which predicts irradiation time-dependent biological response to low dose rate ionizing radiation, by analyzing micronucleus formation and growth inhibition in a human osteosarcoma cell line, exposed to wide range of doses and dose rates of gamma-rays. MOE model demonstrates that logarithm of median effective dose exponentially increases in low dose rates, and thus suggests that the risk approaches to zero at infinitely low dose rate. In this paper, we extend the analysis in various kinds of human cell lines exposed to ionizing radiation for more than a year. We measured micronucleus formation and [ 3 H]thymidine uptake in human cell lines including an osteosarcoma, a DNA-dependent protein kinase-deficient glioma, a SV40-transformed fibroblast derived from an ataxia telangiectasia patient, a normal fibroblast, and leukemia cell lines. Cells were exposed to gamma-rays in irradiation room bearing 50,000 Ci of cobalt-60. After the irradiation, they were cultured for 24 h in the presence of cytochalasin B to block cytokinesis, and cytoplasm and nucleus were stained with DAPI and prospidium iodide. The number of binuclear cells bearing a micronucleus was counted under a fluorescence microscope. For proliferation inhibition, cells were cultured for 48 h after the irradiation and [ 3 H] thymidine was pulsed for 4 h before harvesting. We statistically analyzed the data for quantitative evaluation of radiation risk. While dose and dose rate relationship cultured within one month followed MOE model in cell lines holding wild-type DNA repair system, dose rate effect was greatly impaired in DNA repair-deficient cell lines

  16. Low dose effects and non-monotonic dose responses for endocrine active chemicals: Science to practice workshop: Workshop summary

    DEFF Research Database (Denmark)

    Beausoleil, Claire; Ormsby, Jean-Nicolas; Gies, Andreas

    2013-01-01

    A workshop was held in Berlin September 12–14th 2012 to assess the state of the science of the data supporting low dose effects and non-monotonic dose responses (“low dose hypothesis”) for chemicals with endocrine activity (endocrine disrupting chemicals or EDCs). This workshop consisted of lectu...

  17. Multilevel mechanisms of stimulatory effect of low dose radiation on immunity

    International Nuclear Information System (INIS)

    Shu-Zeng Liu

    1992-01-01

    Attention is paid to the effects of low level ionizing radiation on humans. The conference is devoted to low dose radiation and defense mechanisms of the body. Due to the importance of the immune system in body resistance, special attention has been given to host defense mechanisms following exposure to different doses of ionizing radiation. The immune system has long been known to be highly sensitive to moderate to high doses of ionizing radiation with immuno-depression as one of the most important causes of death in acute radiation syndrome. However, the dose-effect relationship of immune functions has been found to be quite different in the low dose range, especially with doses within 0.1 Gy. With doses above 0.5 Gy most immunologic parameters show a dose dependent depression. With doses between 0.1-0.5 Gy there may be no definite changes in immune functions. Doses within 0.1 Gy, given in single or chronic exposures, have been found to stimulate many immune responses. (author). 16 refs., 2 figs., 7 tabs

  18. Model predictions and analysis of enhanced biological effectiveness at low dose rates

    International Nuclear Information System (INIS)

    Watt, D.E.; Sykes, C.E.; Younis, A.-R.S.

    1988-01-01

    A severe challenge to all models purporting to describe the biological effects of ionizing radiation has arisen with the discovery of two phenomena: the anomalous trend with dose rate of the frequency of neoplastic transformation of mammalian cells and the apparent excessive damaging power of electron-capture radionuclides when incorporated into cell nuclei. A new model is proposed which predicts and enables interpretation of these phenomena. Radiation effectiveness is found to be expressible absolutely in terms of the geometrical cross-sectional area of the radiosensitive sites. The duration of the irradiation, the mean free path for ionization, the influence of particles in the slowing-down spectrum perrtaining in the medium and two collective time factors determining the mean repair rate and the mean lifetime of unidentified reactive chemical species [pt

  19. Effective dose to radon considering people's activities

    International Nuclear Information System (INIS)

    Shimo, M.; Seki, K.; Kikuchi, I.

    1992-01-01

    The tidal volume was estimated for evaluating the effective dose due to radon concentration in the atmosphere. In this study regional population was separated to vocation and non-vocation. The occupancy time and the breathing rate for both vocation and non-vocation groups were estimated, and the annual tidal volume for both groups were calculated. Human actions were separated to 18 activities in the process for estimating the breathing rate. It was clear that the breathing rate depended on human activity and that the human activity changed with its age, so the breathing rate varied with age. Finally the effective doses due to radon and radon progeny indoors and outdoors were evaluated. The maximum annual effective dose was estimated to be 1.2 mSv, minimum 0.2 mSv, and mean 0.51 mSv for vocation. For non-vocation, the male maximum value 0.43 mSv was obtained at the 16 age and the minimum 0.12 mSv at the 70 age, whereas female maximum 0.26 mSv was obtained at the 12 age and the minimum 0.11 mSv at the 70 age. In addition in this study objective areas are Aichi, Gifu, and Mie prefectures for vocation and only Aichi prefecture for non-vocation. (author)

  20. Survey of computed tomography doses in head and chest protocols

    International Nuclear Information System (INIS)

    Souza, Giordana Salvi de; Silva, Ana Maria Marques da

    2016-01-01

    Computed tomography is a clinical tool for the diagnosis of patients. However, the patient is subjected to a complex dose distribution. The aim of this study was to survey dose indicators in head and chest protocols CT scans, in terms of Dose-Length Product(DLP) and effective dose for adult and pediatric patients, comparing them with diagnostic reference levels in the literature. Patients were divided into age groups and the following image acquisition parameters were collected: age, kV, mAs, Volumetric Computed Tomography Dose Index (CTDIvol) and DLP. The effective dose was found multiplying DLP by correction factors. The results were obtained from the third quartile and showed the importance of determining kV and mAs values for each patient depending on the studied region, age and thickness. (author)

  1. Effects of emitter junction and passive base region on low dose rate effect in bipolar devices

    International Nuclear Information System (INIS)

    Pershenkov, V.S.; Cherepko, S.V.; Maslov, V.B.; Belyakov, V.V.; Sogoyan, A.V.; Ulimov, N.; Emelianov, V.V.

    1999-01-01

    Low dose rate effect in bipolar devices consists in the increase of peripheral surface recombination current with dose rate decrease. This is due to the more rapid positive oxide charge and interface trap density build-up as the dose rate becomes lower. High dose rate elevated temperature irradiation is proposed for simulation if the low dose rate effect. In the present we tried to separate the effect of radiation-induced charge in the thick passivation oxide over the emitter junction and passive base regions of npn bipolar transistor. Its goal is to improve bipolar device design for use in space environments and nuclear installations. Three experiments were made during this work. 1. Experiment on radiation-induced charge neutralization (RICN) effect under elevated temperature was performed to show transistor degradation dependence on emitter-base bias. 2. High dose rate elevated and room temperature irradiation of bipolar transistors were performed to separate effects of emitter-junction and passive base regions. 3. Pre- and post- irradiation hydrogen ambient storage was used to investigate its effect on radiation-induced charge build-up over the passive base region. All experiments were performed with npn and pnp transistors. (authors)

  2. Study of total ionization dose effects in electronic devices

    International Nuclear Information System (INIS)

    Nidhin, T.S.; Bhattacharyya, Anindya; Gour, Aditya; Behera, R.P.; Jayanthi, T.

    2018-01-01

    Radiation effects in electronic devices are a major challenge in the dependable application developments of nuclear power plant instrumentation and control systems. The main radiation effects are total ionization dose (TID) effects, displacement damage dose (DDD) effects and single event effects (SEE). In this study, we are concentrating on TID effects in electronic devices. The focus of the study is mainly on SRAM based field programmable gate arrays (FPGA) along with that the devices of our interest are voltage regulators, flash memory and optocoupler. The experiments are conducted by exposing the devices to gamma radiation in power off condition and the degradation in the performances are analysed

  3. An effective dose of ketamine for eliminating pain during injection of propofol: a dose response study.

    Science.gov (United States)

    Wang, M; Wang, Q; Yu, Y Y; Wang, W S

    2013-09-01

    Ketamine can completely eliminate pain associated with propofol injection. However, the effective dose of ketamine to eliminate propofol injection pain has not been determined. The purpose of this study was to determine the effective dose of ketamine needed to eliminate pain in 50% and 95% of patients (ED50 and ED95, respectively) during propofol injections. This study was conducted in a double-blinded fashion and included 50 patients scheduled for elective gynecological laparoscopy under general anesthesia. The initial dose of ketamine used in the first patient was 0.25mg/kg. The dosing modifications were in increments or decrements of 0.025 mg/kg. Ketamine was administered 15 seconds before injecting propofol (2.5mg/kg), which was injected at a rate of 1mL/s. Patients were asked to rate their pain during propofol injection every 5s econds using a 0-3 pain scale. The highest pain score was recorded. The ED50, ED95 and 95% confidence intervals (CI) were determined by probit analyses. The dose of ketamine ranged from 0.175 to 0.275 mg/kg. The ED50 and ED95 of ketamine for eliminating pain during propofol injection were 0.227 mg/kg and 0.283 mg/kg, respectively (95%CI: 0.211-0.243 mg/kg and 0.26-0.364 mg/kg, respectively). Ketamine at an approximate dose of 0.3mg/kg was effective in eliminating pain during propofol injection. Copyright © 2013 Société française d’anesthésie et de réanimation (Sfar). Published by Elsevier SAS. All rights reserved.

  4. A user's guide to the POPFOOD computer code for evaluating ingestion collective doses

    International Nuclear Information System (INIS)

    Nair, S.; Palamountain, J.

    1980-09-01

    A complete description is given of the wide range of user options available for running the POPFOOD computer code, which was developed for the calculation of annual ingestion collective doses from routine atmospheric discharges of radioactivity in the UK. The various options have been depicted pictorially to allow the prospective user to obtain a rapid appreciation of their scope. Facilities for modifying temporarily the library and input data are also described. In addition, input and output data for a sample test case, covering broad range of the various available options, are provided to facilitate programme testing. POPFOOD is written in Fortran IV (level H). The programme is compiled under release 20.6, OPT=2 on the IBM 370/165 computer. (author)

  5. Radon effective dose from TENORM waste associated with petroleum industries

    International Nuclear Information System (INIS)

    Abo-Elmagd, M.; Soliman, H. A.; Daif, M. M.

    2009-01-01

    Technically enhanced naturally occurring radioactive material (TENORM) associated with petroleum industries can be accumulated with elevated quantities and therefore can threat the workers through external and internal exposure. Measurements of radon-related parameters give information about the radioactivity levels in the TENORM waste using the well-established correlation. Also, it is useful to calculate the internal exposure due to radon inhalation in terms of effective radon dose. Among radon-related parameters, areal exhalation rate is the most suitable for characterising land and objects with only upper surface contamination in the case of petroleum waste. The TENORM in this study is collected from waste storage areas located near oil fields at south Sinai governorate (Egypt). The average values of exhalation rates as measured by Lucas cell based on delay count method are 273 ± 144 and 38 ± 8 Bq m -2 h -1 for scale and sludge, respectively. Whereas, two count method gives results with 18 and 20 % lower values for scale and sludge, respectively with good correlation coefficient of 0.999 and 0.852, respectively. Sealed cup fitted with CR-39 gives results compatible with Lucas cell with minor deviation in case of scale due to its thoron content. The results of CR-39 are qualified by taking into consideration the correction for back diffusion effect. The effective radon dose was calculated for different simulated radioactive waste storage areas with different contaminated areas and air ventilation rate. Minimising the contaminated areas and building up efficient ventilation systems can reduce the internal exposure even in the case of RWSA-containing TENORM with elevated radioactivity. (authors)

  6. Simulation of dose reduction in tomosynthesis

    International Nuclear Information System (INIS)

    Svalkvist, Angelica; Baath, Magnus

    2010-01-01

    Purpose: Methods for simulating dose reduction are valuable tools in the work of optimizing radiographic examinations. Using such methods, clinical images can be simulated to have been collected at other, lower, dose levels without the need of additional patient exposure. A recent technology introduced to healthcare that needs optimization is tomosynthesis, where a number of low-dose projection images collected at different angles is used to reconstruct section images of an imaged object. The aim of the present work was to develop a method of simulating dose reduction for digital radiographic systems, suitable for tomosynthesis. Methods: The developed method uses information about the noise power spectrum (NPS) at the original dose level and the simulated dose level to create a noise image that is added to the original image to produce an image that has the same noise properties as an image actually collected at the simulated dose level. As the detective quantum efficiency (DQE) of digital detectors operating at the low dose levels used for tomosynthesis may show a strong dependency on the dose level, it is important that a method for simulating dose reduction for tomosynthesis takes this dependency into account. By applying an experimentally determined relationship between pixel mean and pixel variance, variations in both dose and DQE in relevant dose ranges are taken into account. Results: The developed method was tested on a chest tomosynthesis system and was shown to produce NPS of simulated dose-reduced projection images that agreed well with the NPS of images actually collected at the simulated dose level. The simulated dose reduction method was also applied to tomosynthesis examinations of an anthropomorphic chest phantom, and the obtained noise in the reconstructed section images was very similar to that of an examination actually performed at the simulated dose level. Conclusions: In conclusion, the present article describes a method for simulating dose

  7. Pulse and integral optically stimulated luminescence (OSL). Similarities and dissimilarities to thermoluminescence (TL) dose dependence and dose-rate effects

    International Nuclear Information System (INIS)

    Chen, R.; Leung, P.L.

    2000-01-01

    Optically stimulated luminescence (OSL) and thermoluminescence (Tl) are two possible methods to monitor the absorbed radiation in solid samples, and therefore are utilized for dosimetry. For this application, two properties are desirable, namely, linear dose dependence of the measured quantity and dose-rate independence. For Tl, different kinds of super linear dose dependence have been reported in the literature in different materials, and in some cases, dose-rate dependence has also been found. These have been explained as being the result of competition. In OSL, some recent works reported on super linear dose dependence in annealed samples. In the present work, we explain the possible occurrence of these phenomena in OSL by solving numerically the relevant rate equations governing the process during irradiation, relaxation and read-out (heating or light stimulation). The results show that for short pulse OSL, quadratic dose dependence can be expected when only one trapping state and one kind of recombination center are involved and when the excitation starts with empty traps and centers. With the short pulse OSL, the calculation also reveals a possible dose-rate effect. Under the same circumstances, the area under the OSL curve depends linearly on the dose. The dependence of the whole area under the OSL curve on the dose is shown to be super linear when a disconnected trapping state or radiationless center take part in the process. Also, dose-rate effect can be expected in these cases, although no experimental effect of this sort has been reported so far. In pulse OSL, the analogy is made between the measured intensity and the initial rise range of non-first order Tl, whereas for the total area OSL, there is a nearly full analogy with the dose behavior of the Tl maximum. (Author)

  8. Effective dose and organ doses estimation taking tube current modulation into account with a commercial software package

    International Nuclear Information System (INIS)

    Lopez-Rendon, X.; Bosmans, H.; Zanca, F.; Oyen, R.

    2015-01-01

    To evaluate the effect of including tube current modulation (TCM) versus using the average mAs in estimating organ and effective dose (E) using commercial software. Forty adult patients (24 females, 16 males) with normal BMI underwent chest/abdomen computed tomography (CT) performed with TCM at 120 kVp, reference mAs of 110 (chest) and 200 (abdomen). Doses to fully irradiated organs (breasts, lungs, stomach, liver and ovaries) and E were calculated using two versions of a dosimetry software: v.2.0, which uses the average mAs, and v.2.2, which accounts for TCM by implementing a gender-specific mAs profile. Student's t-test was used to assess statistically significant differences between organ doses calculated with the two versions. A statistically significant difference (p < 0.001) was found for E on chest and abdomen CT, with E being lower by 4.2 % when TCM is considered. Similarly, organ doses were also significantly lower (p < 0.001): 13.7 % for breasts, 7.3 % for lungs, 9.1 % for the liver and 8.5 % for the stomach. Only the dose to the ovaries was higher with TCM (11.5 %). When TCM is used, for the stylized phantom, the doses to lungs, breasts, stomach and liver decreased while the dose to the ovaries increased. (orig.)

  9. Effective dose and organ doses estimation taking tube current modulation into account with a commercial software package

    Energy Technology Data Exchange (ETDEWEB)

    Lopez-Rendon, X. [KU Leuven, Department of Imaging and Pathology, Division of Medical Physics and Quality Assessment, Herestraat 49, box 7003, Leuven (Belgium); Bosmans, H.; Zanca, F. [KU Leuven, Department of Imaging and Pathology, Division of Medical Physics and Quality Assessment, Herestraat 49, box 7003, Leuven (Belgium); University Hospitals Leuven, Department of Radiology, Leuven (Belgium); Oyen, R. [University Hospitals Leuven, Department of Radiology, Leuven (Belgium)

    2015-07-15

    To evaluate the effect of including tube current modulation (TCM) versus using the average mAs in estimating organ and effective dose (E) using commercial software. Forty adult patients (24 females, 16 males) with normal BMI underwent chest/abdomen computed tomography (CT) performed with TCM at 120 kVp, reference mAs of 110 (chest) and 200 (abdomen). Doses to fully irradiated organs (breasts, lungs, stomach, liver and ovaries) and E were calculated using two versions of a dosimetry software: v.2.0, which uses the average mAs, and v.2.2, which accounts for TCM by implementing a gender-specific mAs profile. Student's t-test was used to assess statistically significant differences between organ doses calculated with the two versions. A statistically significant difference (p < 0.001) was found for E on chest and abdomen CT, with E being lower by 4.2 % when TCM is considered. Similarly, organ doses were also significantly lower (p < 0.001): 13.7 % for breasts, 7.3 % for lungs, 9.1 % for the liver and 8.5 % for the stomach. Only the dose to the ovaries was higher with TCM (11.5 %). When TCM is used, for the stylized phantom, the doses to lungs, breasts, stomach and liver decreased while the dose to the ovaries increased. (orig.)

  10. Assessment of the effective supplementary doses for people belonging to a critical group placed nearby an uranium mining zone

    International Nuclear Information System (INIS)

    Aurelian, Florian; Popescu, Mihai; Georgescu, Dan

    2008-01-01

    Full text: The paper presents a case study concerning the impact on environment and population of a exploration uranium mining area. The paper is structured on three levels and presents: First stage will consist of the investigation and characterization of the sources, respectively the transfer pathways: terrestrial, aerial and aquatic ones followed by the assessment of the effective supplementary doses received by the people of population through all the transfer pathways based on some scenarios according to which their presence was permanent or temporary. Second stage concerns the assessment of the supplementary effective doses for the working staff during the caring out the closing workings. There are references concerning the monitoring 'of rehabilitation' during the time when the disaffection workings are ongoing beside the survey of the professional exposed people and the calculation of the supplementary doses for people of population and the ones belonging to the critical group during the disaffection time. Within the third stage framework there are calculated, described and discussed the individual and collective effective doses for people belonging to the population and to the critical groups, which it is expected to be recorded after the disaffection works cessation. The last part of the paper focuses on the long-term miniaturization of the environmental factors following the disaffection works conclusion and on the long-term evolution of the supplementary doses as well. (author)

  11. High-dose zolpidem dependence - Psychostimulant effects? A case report and literature review

    Directory of Open Access Journals (Sweden)

    Abhijna Chandan Chattopadhyay

    2016-01-01

    Full Text Available Zolpidem, an imidazoline nonbenzodiazepine sedative drug, is used widely. Initial reports showed minimal abuse potential. However, multiple reports have appeared of dose escalation and abuse. Subjective effects of high-dose zolpidem are not known. In light of accumulating evidence of abuse potential, we hereby report a case of high-dose dependence and a review of relevant literature. A 33-year-old male presented with 5 years of daily use of 600–1700 mg of zolpidem tartrate. He reported subjective effects of euphoria, intense craving, and inability to stop use. Loss of receptor specificity, pharmacokinetic factors, and different receptor distributions can explain paradoxical stimulatory effects of high-dose zolpidem. Further studies are required to characterize subjective effects of high-dose zolpidem.

  12. Computational assessment of effective dose and patient specific doses for kilovoltage stereotactic radiosurgery of wet age-related macular degeneration

    Science.gov (United States)

    Hanlon, Justin Mitchell

    Age-related macular degeneration (AMD) is a leading cause of vision loss and a major health problem for people over the age of 50 in industrialized nations. The current standard of care, ranibizumab, is used to help slow and in some cases stabilize the process of AMD, but requires frequent invasive injections into the eye. Interest continues for stereotactic radiosurgery (SRS), an option that provides a non-invasive treatment for the wet form of AMD, through the development of the IRay(TM) (Oraya Therapeutics, Inc., Newark, CA). The goal of this modality is to destroy choroidal neovascularization beneath the pigment epithelium via delivery of three 100 kVp photon beams entering through the sclera and overlapping on the macula delivering up to 24 Gy of therapeutic dose over a span of approximately 5 minutes. The divergent x-ray beams targeting the fovea are robotically positioned and the eye is gently immobilized by a suction-enabled contact lens. Device development requires assessment of patient effective dose, reference patient mean absorbed doses to radiosensitive tissues, and patient specific doses to the lens and optic nerve. A series of head phantoms, including both reference and patient specific, was derived from CT data and employed in conjunction with the MCNPX 2.5.0 radiation transport code to simulate treatment and evaluate absorbed doses to potential tissues-at-risk. The reference phantoms were used to evaluate effective dose and mean absorbed doses to several radiosensitive tissues. The optic nerve was modeled with changeable positions based on individual patient variability seen in a review of head CT scans gathered. Patient specific phantoms were used to determine the effect of varying anatomy and gaze. The results showed that absorbed doses to the non-targeted tissues were below the threshold levels for serious complications; specifically the development of radiogenic cataracts and radiation induced optic neuropathy (RON). The effective dose

  13. Dose-rate dependent stochastic effects in radiation cell-survival models

    International Nuclear Information System (INIS)

    Sachs, R.K.; Hlatky, L.R.

    1990-01-01

    When cells are subjected to ionizing radiation the specific energy rate (microscopic analog of dose-rate) varies from cell to cell. Within one cell, this rate fluctuates during the course of time; a crossing of a sensitive cellular site by a high energy charged particle produces many ionizations almost simultaneously, but during the interval between events no ionizations occur. In any cell-survival model one can incorporate the effect of such fluctuations without changing the basic biological assumptions. Using stochastic differential equations and Monte Carlo methods to take into account stochastic effects we calculated the dose-survival rfelationships in a number of current cell survival models. Some of the models assume quadratic misrepair; others assume saturable repair enzyme systems. It was found that a significant effect of random fluctuations is to decrease the theoretically predicted amount of dose-rate sparing. In the limit of low dose-rates neglecting the stochastic nature of specific energy rates often leads to qualitatively misleading results by overestimating the surviving fraction drastically. In the opposite limit of acute irradiation, analyzing the fluctuations in rates merely amounts to analyzing fluctuations in total specific energy via the usual microdosimetric specific energy distribution function, and neglecting fluctuations usually underestimates the surviving fraction. The Monte Carlo methods interpolate systematically between the low dose-rate and high dose-rate limits. As in other approaches, the slope of the survival curve at low dose-rates is virtually independent of dose and equals the initial slope of the survival curve for acute radiation. (orig.)

  14. Comparison of 2-Dose and 3-Dose 9-Valent Human Papillomavirus Vaccine Schedules in the United States: A Cost-effectiveness Analysis.

    Science.gov (United States)

    Laprise, Jean-François; Markowitz, Lauri E; Chesson, Harrell W; Drolet, Mélanie; Brisson, Marc

    2016-09-01

    A recent clinical trial using the 9-valent human papillomavirus virus (HPV) vaccine has shown that antibody responses after 2 doses are noninferior to those after 3 doses, suggesting that 2 and 3 doses may have comparable vaccine efficacy. We used an individual-based transmission-dynamic model to compare the population-level effectiveness and cost-effectiveness of 2- and 3-dose schedules of 9-valent HPV vaccine in the United States. Our model predicts that if 2 doses of 9-valent vaccine protect for ≥20 years, the additional benefits of a 3-dose schedule are small as compared to those of 2-dose schedules, and 2-dose schedules are likely much more cost-efficient than 3-dose schedules. © The Author 2016. Published by Oxford University Press for the Infectious Diseases Society of America. All rights reserved. For permissions, e-mail journals.permissions@oup.com.

  15. Patient effective dose from endovascular brachytherapy with 192Ir Sources

    International Nuclear Information System (INIS)

    Perna, L.; Bianchi, C.; Novario, R.; Nicolini, G.; Tanzi, F.; Conte, L.

    2002-01-01

    The growing use of endovascular brachytherapy has been accompanied by the publication of a large number of studies in several fields, but few studies on patient dose have been found in the literature. Moreover, these studies were carried out on the basis of Monte Carlo simulation. The aim of the present study was to estimate the effective dose to the patient undergoing endovascular brachytherapy treatment with 192 Ir sources, by means of experimental measurements. Two standard treatments were taken into account: an endovascular brachytherapy of the coronary artery corresponding to the activity x time product of 184 GBq.min and an endovascular brachytherapy of the renal artery (898 GBq.min). Experimental assessment was accomplished by thermoluminescence dosemeters positioned in more than 300 measurement points in a properly adapted Rando phantom. A method has been developed to estimate the mean organ doses for all tissues and organs concerned in order to calculate the effective dose associated with intravascular brachytherapy. The normalised organ doses resulting from coronary treatment were 2.4x10 -2 mSv.GBq -1 .min -1 for lung, 0.9x10 -2 mSv.GBq -1 .min -1 for oesophagus and 0.48x10 -2 mSv.GBq -1 .min -1 for bone marrow. During brachytherapy of the renal artery, the corresponding normalised doses were 4.2x10 -2 mSv.GBq -1 .min -1 for colon, 7.8x10 -2 mSv.GBq -1 .min -1 for stomach and 1.7x10 -2 mSv.GBq -1 .min -1 for liver. Coronary treatment involved an effective dose of 0.046 mSv.GBq -1 .min -1 , whereas the treatment of the renal artery resulted in an effective dose of 0.15 mSv.GBq -1 .min -1 ; there were many similarities with data from former studies. Based on these results it can be concluded that the dose level of patients exposed during brachytherapy treatment is low. (author)

  16. ALARA review of the maintenance and repair jobs of repetitive high radiation dose at Kori Unit 3 and 4

    International Nuclear Information System (INIS)

    Cho, Y.H.; Moon, J.H.; Kang, C.S.; Lee, J.S.; Lee, D.H.

    2003-01-01

    The policy of maintaining occupational radiation dose (ORD) as low as reasonably achievable (ALARA) requires the effective reduction of ORD in the phases of design as well as operation of nuclear power plants. It has been identified that a predominant portion of ORD arises during maintenance and repair operations at nuclear power plants. The cost-effective reduction of ORD cannot be achieved without a comprehensive analysis of accumulated ORD data of existing nuclear power plants. To identify the jobs of repetitive high ORD, the ORD data of Kori Units 3 and 4 over 10-year period from 1986 to 1995 were compiled into the PC-based ORD database program. As the radiation job classification structure, 26 main jobs are considered, most of which are further subdivided into detailed jobs. According to the order of the collective dose values for 26 main jobs, 10 jobs of high collective dose are identified. As an ALARA review, then, top 10 jobs of high collective dose are statistically analyzed with regard to 1) dose rate, 2) crew number and 3) job frequency that are the factors determining the collective dose for the radiation job of interest. Through the ALARA review, main reasons causing to high collective dose values are identified as follows. The high collective dose of RCP maintenance job is mainly due to the large crew number and the high job frequency. The characteristics of refueling job are similar to those of RCP maintenance job. However, the high collective doses of SG-related jobs such as S/G nozzle dam job, S/G man-way job and S/G tube maintenance job are mainly due to high radiation dose rate. (author)

  17. Collective radiation dose from diagnostic x-ray examination in nine ...

    African Journals Online (AJOL)

    Background: Medical x-ray exposures have the largest man made source of population exposure to ionizing radiation in different countries. Recent developments in medical imaging have led to rapid increases in a number of high dose xray examinations performed with significant consequences for individual patient doses ...

  18. Estimation of effective doses in pediatric X-ray computed tomography examination.

    Science.gov (United States)

    Obara, Hideki; Takahashi, Midori; Kudou, Kazuya; Mariya, Yasushi; Takai, Yoshihiro; Kashiwakura, Ikuo

    2017-11-01

    X-ray computed tomography (CT) images are used for diagnostic and therapeutic purposes in various medical disciplines. In Japan, the number of facilities that own diagnostic CT equipment, the number of CT examinations and the number of CT scanners increased by ~1.4-fold between 2005 and 2011. CT operators (medical radiological technologists, medical physicists and physicians) must understand the effective doses for examinations at their own institutions and carefully approach each examination. In addition, the patients undergoing the examination (as well as his/her family) must understand the effective dose of each examination in the context of the cumulative dose. In the present study, the numbers of pediatric patients (aged 0-5 years) and total patients who underwent CT at Hirosaki University Hospital (Hirosaki, Japan) between January 2011 and December 2013 were surveyed, and effective doses administered to children aged 0, 1 and 5 years were evaluated. Age- and region-specific conversion factors and dose-length products obtained from the CT scanner were used to estimate the effective doses. The numbers of CT examinations performed in 2011, 2012 and 2013 were 16,662, 17,491 and 17,649, respectively, of which 613 (1.2%) of the overall total involved children aged 0-5 years. The estimated effective doses per examination to children aged 0, 1 and 5 years were 6.3±4.8, 4.9±3.8 and 2.7±3.0 mSv, respectively. This large variation was attributed to several factors associated with scan methods and ranges in actual setting. In conclusion, the requirement for individual patient prospective exposure management systems and estimations of low-dose radiation exposure should be considered in light of the harmful effects of exposure.

  19. Dosimetric Effects of Air Pockets Around High-Dose Rate Brachytherapy Vaginal Cylinders

    International Nuclear Information System (INIS)

    Richardson, Susan; Palaniswaamy, Geethpriya; Grigsby, Perry W.

    2010-01-01

    Purpose: Most physicians use a single-channel vaginal cylinder for postoperative endometrial cancer brachytherapy. Recent published data have identified air pockets between the vaginal cylinders and the vaginal mucosa. The purpose of this research was to evaluate the incidence, size, and dosimetric effects of these air pockets. Methods and Materials: 25 patients receiving postoperative vaginal cuff brachytherapy with a high-dose rate vaginal cylinders were enrolled in this prospective data collection study. Patients were treated with 6 fractions of 200 to 400 cGy per fraction prescribed at 5 mm depth. Computed tomography simulation for brachytherapy treatment planning was performed for each fraction. The quantity, volume, and dosimetric impact of the air pockets surrounding the cylinder were quantified. Results: In 25 patients, a total of 90 air pockets were present in 150 procedures (60%). Five patients had no air pockets present during any of their treatments. The average number of air pockets per patient was 3.6, with the average total air pocket volume being 0.34 cm 3 (range, 0.01-1.32 cm 3 ). The average dose reduction to the vaginal mucosa at the air pocket was 27% (range, 9-58%). Ten patients had no air pockets on their first fraction but air pockets occurred in subsequent fractions. Conclusion: Air pockets between high-dose rate vaginal cylinder applicators and the vaginal mucosa are present in the majority of fractions of therapy, and their presence varies from patient to patient and fraction to fraction. The existence of air pockets results in reduced radiation dose to the vaginal mucosa.

  20. The biological effects of low doses of radiation: medical, biological and ecological aspects

    International Nuclear Information System (INIS)

    Gun-Aajav, T.; Ajnai, L.; Manlaijav, G.

    2007-01-01

    Full text: The results of recent studies show that low doses of radiation make many different structural and functional changes in a cell and these changes are preserved for a long time. This phenomenon is called as effects of low doses of radiation in biophysics, radiation biology and radiation medicine. The structural and functional changes depend on doses and this dependence has non-linear and bimodal behaviour. More detail, the radiation effect goes up and reaches its maximum (Low doses maximum) in low doses region, then it goes down and takes its stationary means (there is a negative effect in a few cases). With increases in doses and with further increases it goes up. It is established that low dose's maximum depends on physiological state of a biological object, radiation quality and dose rate. During the experiments another special date was established. This specialty is that many different physical and chemical factors are mutually connected and have synergetic behaviour. At present, researches are concentrating their attention on the following three directions: 1. Direct and indirect interaction of radiation's low doses: 2. Interpretation of its molecular mechanism, regulation of the positive effects and elaboration of ways o removing negative effects: 3. Application of the objective research results into practice. In conclusion the authors mention the current concepts on interpretation of low doses effect mechanism, forward their own views and emphasize the importance of considering low doses effects in researches of environmental radiation pollution, radiation medicine and radiation protection. (author)

  1. Effect of low dose ionizing radiation upon concentration of

    International Nuclear Information System (INIS)

    Viliae, M.; Kraljeviae, P.; Simpraga, M.; Miljaniae, S.

    2004-01-01

    It is known that low dose ionizing radiation might have stimulating effects (Luckey, 1982, Kraljeviae, 1988). This fact has also been confirmed in the previous papers of Kraljeviae et al. (2000-2000a; 2001). Namely, those authors showed that irradiation of chicken eggs before incubation by a low dose of 0.15 Gy gamma radiation increases the activity aspartateaminotrasferases (AST) and alanine-aminotransferases (ALT) in blood plasma of chickens hatched from irradiated eggs, as well as growth of chickens during the fattening period. Low doses might also cause changes in the concentration of some biochemical parameters in blood plasma of the same chickens such as changes in the concentration of total proteins, glucose and cholesterol. In this paper, an attempt was made to investigate the effects of low dose gamma radiation upon the concentration of sodium and potassium in the blood plasma of chickens which were hatched from eggs irradiated on the 19th day of incubation by dose of 0.15 Gy. Obtained results were compared with the results from the control group (chickens hatched from nonirradiated eggs). After hatching, all other conditions were the same for both groups. Blood samples were drawn from heart, and later from the wing vein on days 1, 3, 5, 7, 10, 20, 30 and 42. The concentration of sodium and potassium was determined spectrophotometrically by atomic absorbing spectrophotometer Perkin-Elmer 1100B. The concentration of sodium and potassium in blood plasma of chickens hatched from eggs irradiated on the 19th day of incubation by dose of 0.15 Gy indicated a statistically significant increase (P>0.01) only on the first day of the experiment. Obtained results showed that irradiation of eggs on the 19th day of incubation by dose of 0.15 Gy gamma radiation could have effects upon the metabolism of electrolytes in chickens. (Author)

  2. Task related doses in spanish light water reactors over the period 1990-1996

    International Nuclear Information System (INIS)

    Aroca, J.; Montesinos, J.J.; O'Donnell, P.; Amor, I.; Butragueno, J.L.

    1998-01-01

    In order to evaluate in depth the effectiveness of the practical application of the ALARA principle in Spanish nuclear facilities -7 PWR (6 Westinghouse and 1 KWU-Siemens) and 2 BWR (Generic Electric), and to have a further overview of dose trends, the CSN has analysed the task related doses data over the period 1990-1996. The scope of this analysis includes the collective dose and relative relevance for 18 different refuelling outage tasks, some sub-tasks, 12 department staff, and the main consolidated dose reduction-techniques and good practices. Data has been collected from the outage reports NPPs provide according to the CSN 1.5 Safety Guide format. (Author)

  3. Results of the Austrian CT dose study 2010. Typical effective doses of the most frequent CT examinations; Ergebnisse der Oesterreichischen CT-Dosisstudie 2010. Effektive Dosen der haeufigsten CT-Untersuchungen und Unterschiede zwischen Anwendern

    Energy Technology Data Exchange (ETDEWEB)

    Homolka, Peter; Leithner, Robert; Billinger, Jochen [Medizinische Universitaet Wien (Austria). Zentrum fuer Medizinische Physik und Biomedizinische Technik; Gruber, Michael [Medizinische Universitaet Wien (Austria). Universitaetsklinik fuer Radiologie und Nuklearmedizin

    2014-10-01

    Purpose: To determine typical doses from common CT examinations of standard sized adult patients and their variability between CT operators for common CT indications. Materials and Methods: In a nationwide Austrian CT dose survey doses from approx. 10,000 common CT examinations of adults during 2009 and 2010 were collected and 'typical' radiation doses to the 'average patient', which turned out to have 75.6 kg body mass, calculated. Conversion coefficients from DLP to effective dose were determined and effective doses calculated according to ICRP 103. Variations of typically applied doses to the 'average patient' were expressed as ratios between 90{sup th} and 10{sup th} percentile (inter-percentile width, IPW90/10), 1st and 3{sup rd} quartile (IPW75/25), and Maximum/Minimum. Results: Median effective doses to the average patients for standard head and neck scans were 1.8 mSv (cervical spine), 1.9 mSv (brain: trauma/bleeding, stroke) to 2.2 mSv (brain: masses) with typical variation between facilities of a factor 2.5 (IPW90/10) and 1.7 (IPW75/25). In the thorax region doses were 6.4 to 6.8 mSv (pulmonary embolism, pneumonia and inflammation, oncologic scans), the variation between facilities was by a factor of 2.1 (IPW90/10) and 1.5 (IPW75/25), respectively. In the abdominal region median effective doses from 6.5 mSv (kidney stone search) to 22 mSv (liver lesions) were found (acute abdomen, staging/metastases, lumbar spine: 9-12 mSv; oncologic abdomen plus chest 16 mSv; renal tumor 20 mSv). Variation factors between facilities were on average for abdominal scans 2.7 (IPW90/10) and 1.8 (IPW75/25). Conclusion: Variations between CT operators are generally moderate for most operators, but in some indications the ratio between the minimum and the maximum of average dose to the typical standard patients exceeds a factor of 4 or even 5. Therefore, comparing average doses to Diagnostic Reference Levels (DRLs) and optimizing protocols need to

  4. Effect of dose and dose rate of gamma radiation on catalytic activity of catalase

    International Nuclear Information System (INIS)

    Vaclav Cuba; Tereza Pavelkova; Viliam Mucka

    2010-01-01

    Catalytic activity of gamma irradiated catalase from bovine liver was studied for hydrogen peroxide decomposition at constant temperature and pressure. The measurement was performed at temperatures 27, 32, 37, 42 and 47 deg C. Solutions containing 1 and 0.01 g dm -3 of catalase in phosphate buffer were used for the study. Repeatability of both sample preparation and kinetics measurement was experimentally verified. Rate constants of the reaction were determined for all temperatures and the activation energy was evaluated from Arrhenius plot. Gamma irradiation was performed using 60 Co radionuclide source Gammacell 220 at two different dose rates 5.5 and 70 Gy h -1 , with doses ranging from 10 to 1000 Gy. The observed reaction of irradiated and non-irradiated catalase with hydrogen peroxide is of the first order. Irradiation significantly decreases catalytic activity of catalase, but the activation energy does not depend markedly on the dose. The effect of irradiation is more significant at higher dose rate. (author)

  5. Benefits of the effective dose equivalent concept at a medical center

    International Nuclear Information System (INIS)

    Vetter, R.J.; Classic, K.L.

    1991-01-01

    A primary objective of the recommendations of the International Committee on Radiological Protection Publication 26 is to insure that no source of radiation exposure is unjustified in relation to its benefits. This objective is consistent with goals of the Radiation Safety Committee and Institutional Review Board at medical centers where research may involve radiation exposure of human subjects. The effective dose equivalent concept facilitates evaluation of risk by those who have little or no knowledge of quantities or biological effects of radiation. This paper presents effective dose equivalent data used by radiation workers and those who evaluate human research protocols as these data relate to personal dosimeter reading, entrance skin exposure, and target organ dose. The benefits of using effective dose equivalent to evaluate risk of medical radiation environments and research protocols are also described

  6. Effects of low doses of ionizing radiation

    International Nuclear Information System (INIS)

    Anon.

    2008-01-01

    Ionizing radiation of cosmic or terrestrial origin is part of the environment in which all living things have evolved since the creation of the universe. The artificial radioactivity generated by medical diagnostic and treatment techniques, some industrial activities, radioactive fallout, etc. has now been added to this natural radioactivity. This article reviews the biological effects of the low doses of ionizing radiation to which the population is thus exposed. Their carcinogenic risk cannot simply be extrapolated from what we know about high-dose exposure. (author)

  7. Effect of age and sex on warfarin dosing

    Directory of Open Access Journals (Sweden)

    Khoury G

    2014-07-01

    Full Text Available Ghada Khoury,1 Marwan Sheikh-Taha2 1School of Pharmacy, 2Department of Pharmacy Practice, Lebanese American University, Byblos, Lebanon Objective: We examined the potential effect of sex and age on warfarin dosing in ambulatory adult patients. Methods: We conducted a retrospective chart review of patients attending an anticoagulation clinic. We included patients anticoagulated with warfarin for atrial fibrillation or venous thromboembolism who had a therapeutic international normalized ratio of 2–3 for 2 consecutive months. We excluded patients who had been on any drug that is known to have a major interaction with warfarin, smokers, and heavy alcohol consumers. Out of 340 screened medical records, 96 met the predetermined inclusion criteria. The primary outcome assessed was warfarin total weekly dose (TWD. Results: There was a statistically significant difference in the TWD among the ages (P<0.01; older patients required lower doses. However there was no statistically significant difference in the TWD between sexes (P=0.281. Conclusion: Age was found to have a significant effect on warfarin dosing. Even though women did require a lower TWD than men, this observation was not statistically significant. Keywords: warfarin, INR, anticoagulation, vitamin K antagonists, age

  8. Analysis of radiation doses to patients from diagnostic department of nuclear medicine

    Energy Technology Data Exchange (ETDEWEB)

    Lepej, L; Messingerova, M [F.D. Rosvelt Hospital, Banska Bystrica (Slovakia). Dept. of Nuclear Medicine; Ftacnikova, S [Inst. of Preventive and Clinical Medicine, Bratislava (Slovakia)

    1996-12-31

    In this paper the values of mean effective dose equivalents per unit activity (H{sub E/1Bq}) were used for the calculation of mean effective dose equivalents for one examination (H{sub E}). The collective effective dose equivalents for each radiopharmaceutical and type of examination (S{sub ER}) and global collective effective dose equivalent for department for all radiopharmaceuticals (S{sub E}) during evaluated period were defined. The data for years from 1992 to 1994 were evaluated and compared with results in literature. The evaluation of radiation doses in nuclear medicine department is useful parameter for internal quality control. Using this method, the radiation dose in this laboratory was changed to minimum (under mean value of Slovak Republic). Unfortunately, the real data of patients radiation doses are different from the calculated one. Due to different kinetic of radiopharmaceuticals in individual patients (influenced by pathology, age, etc.) the evaluation of radiation burden to nuclear medicine patients is problematic. But this approach enable the relative comparison of the changes in values of H{sub E} and S{sub E} during the observed period. The evaluation of individual (minimal) effective dose equivalent - (H{sub min}) which represents dose calculated under physiologic conditions can be useful for indication of diagnostic examination by physicians. Therefore the systematic registration of H{sub min} from all examinations - patient`s radiation history. This is specially important in the case of children and young people. The importance of the proposed method, is in regulation of radiation dose from nuclear medicine diagnostic examinations, not only be the control of number and type of examinations, but also by selection of used radiopharmaceuticals and by the way how to use them. (J.K.) 1 fig., 2 refs.

  9. A system of dose-effects relationships for the Northern wildlife: radiation protection criteria

    International Nuclear Information System (INIS)

    Sazykina, T.G.

    2004-01-01

    The key issue in the assessment system for radiation protection of wildlife is the establishment of a set of dose-effects relationships for reference representatives of natural biota, based on scientific data from a range of doses and a range of radiation effects. Risks to natural populations in particular habitats can be evaluated from a comparison of estimated doses to biota with the scale of dose-effects relationships for different types of biota. Within the frame of the EC Project EPIC 'Environmental Protection from Ionizing Contaminants' 2000-2003), a database has been created, which include the published and unpublished data relating to dose effects relationships for flora and fauna in the Northern and Arctic areas. The EPIC database contains information based exclusively on Russian/FSU experimental and field studies; chronic/lifetime exposures were the focus of the work, owing to the fact that such exposures are the most typical in radiological assessments for biota. In total, the EPIC database radiation effects on biota contains about 1600 records from 440 publications, including datasets on terrestrial and aquatic animals, plants, soil fauna and microorganisms. The EPIC database information cover a very wide range of radiation dose rates to wild flora and fauna: from below 10 -5 Gy d -1 up to more than 1 Gy d -1 . A great variety of radiation effects are registered in the EPIC database, from stimulation at low doses up to death from acute radiation syndrome at high doses. From data, compiled in the EPIC database, the dose-effects relationships were derived for different types of northern organisms. The system of dose-effects relationships forms the scale of severity of radiation effects at increasing levels of chronic radiation exposure. With its focus on the effects of low-to-moderate chronic exposure, the system of dose effects relationships provides a useful tool for scientists and decision-makers to establish safety standards for protecting the

  10. Psilocybin occasioned mystical-type experiences: immediate and persisting dose-related effects.

    Science.gov (United States)

    Griffiths, Roland R; Johnson, Matthew W; Richards, William A; Richards, Brian D; McCann, Una; Jesse, Robert

    2011-12-01

    This dose-effect study extends previous observations showing that psilocybin can occasion mystical-type experiences having persisting positive effects on attitudes, mood, and behavior. This double-blind study evaluated psilocybin (0, 5, 10, 20, 30 mg/70 kg, p.o.) administered under supportive conditions. Participants were 18 adults (17 hallucinogen-naïve). Five 8-h sessions were conducted individually for each participant at 1-month intervals. Participants were randomized to receive the four active doses in either ascending or descending order (nine participants each). Placebo was scheduled quasi-randomly. During sessions, volunteers used eyeshades and were instructed to direct their attention inward. Volunteers completed questionnaires assessing effects immediately after and 1 month after each session, and at 14 months follow-up. Psilocybin produced acute perceptual and subjective effects including, at 20 and/or 30 mg/70 kg, extreme anxiety/fear (39% of volunteers) and/or mystical-type experience (72% of volunteers). One month after sessions at the two highest doses, volunteers rated the psilocybin experience as having substantial personal and spiritual significance, and attributed to the experience sustained positive changes in attitudes, mood, and behavior, with the ascending dose sequence showing greater positive effects. At 14 months, ratings were undiminished and were consistent with changes rated by community observers. Both the acute and persisting effects of psilocybin were generally a monotonically increasing function of dose, with the lowest dose showing significant effects. Under supportive conditions, 20 and 30 mg/70 kg psilocybin occasioned mystical-type experiences having persisting positive effects on attitudes, mood, and behavior. Implications for therapeutic trials are discussed.

  11. Dose assessments for SFR 1

    International Nuclear Information System (INIS)

    Bergstroem, Ulla; Avila, Rodolfo; Ekstroem, Per-Anders; Cruz, Idalmis de la

    2008-05-01

    Following a review by the Swedish regulatory authorities of the safety analysis of the SFR 1 disposal facility for low and intermediate level waste, SKB has prepared an updated safety analysis, SAR-08. This report presents estimations of annual doses to the most exposed groups from potential radionuclide releases from the SFR 1 repository for a number of calculation cases, selected using a systematic approach for identifying relevant scenarios for the safety analysis. The dose estimates can be used for demonstrating that the long term safety of the repository is in compliance with the regulatory requirements. In particular, the mean values of the annual doses can be used to estimate the expected risks to the most exposed individuals, which can then be compared with the regulatory risk criteria for human health. The conversion from doses to risks is performed in the main report. For one scenario however, where the effects of an earthquake taking place close to the repository are analysed, risk calculations are presented in this report. In addition, prediction of concentrations of radionuclides in environmental media, such as water and soil, are compared with concentration limits suggested by the Erica-project as a base for estimating potential effects on the environment. The assessment of the impact on non-human biota showed that the potential impact is negligible. Committed collective dose for an integration period of 10,000 years for releases occurring during the first thousand years after closure are also calculated. The collective dose commitment was estimated to be 8 manSv. The dose calculations were carried out for a period of 100,000 years, which was sufficient to observe peak doses in all scenarios considered. Releases to the landscape and to a well were considered. The peaks of the mean annual doses from releases to the landscape are associated with C-14 releases to a future lake around year 5,000 AD. In the case of releases to a well, the peak annual doses

  12. Dose assessments for SFR 1

    Energy Technology Data Exchange (ETDEWEB)

    Bergstroem, Ulla (Swedish Nuclear Fuel and Waste Management Co., Stockholm (Sweden)); Avila, Rodolfo; Ekstroem, Per-Anders; Cruz, Idalmis de la (Facilia AB, Bromma (Sweden))

    2008-06-15

    Following a review by the Swedish regulatory authorities of the safety analysis of the SFR 1 disposal facility for low and intermediate level waste, SKB has prepared an updated safety analysis, SAR-08. This report presents estimations of annual doses to the most exposed groups from potential radionuclide releases from the SFR 1 repository for a number of calculation cases, selected using a systematic approach for identifying relevant scenarios for the safety analysis. The dose estimates can be used for demonstrating that the long term safety of the repository is in compliance with the regulatory requirements. In particular, the mean values of the annual doses can be used to estimate the expected risks to the most exposed individuals, which can then be compared with the regulatory risk criteria for human health. The conversion from doses to risks is performed in the main report. For one scenario however, where the effects of an earthquake taking place close to the repository are analysed, risk calculations are presented in this report. In addition, prediction of concentrations of radionuclides in environmental media, such as water and soil, are compared with concentration limits suggested by the Erica-project as a base for estimating potential effects on the environment. The assessment of the impact on non-human biota showed that the potential impact is negligible. Committed collective dose for an integration period of 10,000 years for releases occurring during the first thousand years after closure are also calculated. The collective dose commitment was estimated to be 8 manSv. The dose calculations were carried out for a period of 100,000 years, which was sufficient to observe peak doses in all scenarios considered. Releases to the landscape and to a well were considered. The peaks of the mean annual doses from releases to the landscape are associated with C-14 releases to a future lake around year 5,000 AD. In the case of releases to a well, the peak annual doses

  13. Estimated effects on radiation doses from alternatives in a spent fuel transportation system

    International Nuclear Information System (INIS)

    Schneider, K.J.; Ross, W.A.; Smith, R.I.

    1988-07-01

    This paper contains the results of a study of estimated radiation doses to the public and workers from the transport of spent fuel from commercial nuclear power reactors to a geologic repository. A postulated reference rail/legal-weight truck transportation system is defined that would use current transportation technology, and provide a breakdown of activities and time/distance/dose-rate estimates for each activity within the system. Collective doses are estimated for each of the major activities at the reactor site, in transit, and at the repository receiving facility. Annual individual doses to the maximally exposed individuals or groups of individuals are also estimated. The dose-reduction potentials and costs are estimated for a total of 17 conceptual alternatives and subalternatives to the postulated reference system. Most of the alternatives evaluated are estimated to provide both cost and dose reductions. The major conclusion is that the potential exists for significant future reductions in radiation doses to the public and workers and for reductions in costs compared to those based on a continuation of past practices in the US

  14. Estimated effects on radiation doses from alternatives in a spent fuel transportation system

    International Nuclear Information System (INIS)

    Schneider, K.J.; Ross, W.A.; Smith, R.I.

    1988-01-01

    This paper contains the results of a study of estimated radiation doses to the public and workers from the transport of spent fuel from commercial nuclear power reactors to a geologic repository. A postulated reference rail/legal-weight truck transportation system is defined that would use current transportation technology, and provide a breakdown of activities and time/distance/dose-rate estimates for each activity within the system. Collective doses are estimated for each of the major activities at the reactor site, in transit, and at the repository receiving facility. Annual individual doses to the maximally exposed individuals or groups of individuals also estimated. The dose-reduction potentials and costs are estimated for a total of 17 conceptual alternatives and subalternatives to the postulated reference system. Most of the alternatives evaluated are estimated to provide both cost and dose reductions. The major conclusion is that the potential exists for significant future reductions in radiation doses to the public and workers and for reductions in costs compared to those based on a continuation of past practices in the U.S

  15. Ingestion of Nevada Test Site Fallout: Internal dose estimates

    International Nuclear Information System (INIS)

    Whicker, F.W.; Kirchner, T.B.; Anspaugh, L.R.

    1996-01-01

    This paper summarizes individual and collective dose estimates for the internal organs of hypothetical yet representative residents of selected communities that received measurable fallout from nuclear detonations at the Nevada Test Site. The doses, which resulted from ingestion of local and regional food products contaminated with over 20 radionuclides, were estimated with use of the PATHWAY food-chain-transport model to provide estimates of central tendency and uncertainty. The thyroid gland received much higher doses than other internal organs and tissues. In a avery few cases, infants might have received thyroid doses in excess of 1 Gy, depending on location, diet, and timing of fallout. 131 I was the primary thyroid dose contributor, and fresh milk was the main exposure pathway. With the exception of the thyroid, organ doses from the ingestion pathway were much smaller (<3%) than those from external gamma exposure to deposited fallout. Doses to residents living closest to the Nevada Test Site were contributed mainly by a few fallout events; doses to more distantly located people were generally smaller, but a greater number of events provided measurable contributions. The effectiveness of different fallout events in producing internal organ doses through ingestion varied dramatically with seasonal timing of the test, with maximum dose per unit fallout occurring for early summer depositions when milk cows were on pasture and fresh, local vegetables were used. Within specific communities, internal doses differed by age, sex, and lifestyle. Collective internal dose estimates for specific geographic areas are provided

  16. Effect of Low-Dose Irradiation on Biochemical and Immunological Responses

    International Nuclear Information System (INIS)

    Shabon, M.H.; Sayed, Z.S.; El-Gawish, M.A.; Mahdy, E.M.E.; Shosha, W.Gh.

    2008-01-01

    Lipid peroxidation (Malondialdehyde), Lactate dehydrogenase, Iron Concentration, IL-6 and IL-1β concentration were determined in Seventy-two male albino rats divided in two main groups. The first one was subdivided into 7 subgroups; control and 6 irradiated subgroups with 0.1, 0.2, 0.3, 0.5, 0.7, and 1 Gy single dose of gamma radiation. The other was subdivided into 4 irradiated subgroups with fractionated dose .-radiation of 0.3, 0.7 and 1 Gy with 0.1 Gy per day and the last subgroup 1 Gy with 0.2 Gy daily. All animals were sacrificed after three days of the last irradiation dose. The results revealed that all biochemical parameters were increased in rats exposed to fractionated more than single doses. In conclusion, the data of this study highlight on the beneficial and stimulatory effect of low ionizing radiation doses (≥ 1Gy) whether single or fractionated on some biochemical and immunological parameters. These findings may be fruitful for those who undergo radiotherapy as well as the dose-effect relationship

  17. Low-dose neutron dose response of zebrafish embryos obtained from the Neutron exposure Accelerator System for Biological Effect Experiments (NASBEE) facility

    International Nuclear Information System (INIS)

    Ng, C.Y.P.; Kong, E.Y.; Konishi, T.; Kobayashi, A.; Suya, N.; Cheng, S.H.; Yu, K.N.

    2015-01-01

    The dose response of embryos of the zebrafish, Danio rerio, irradiated at 5 h post fertilization (hpf) by 2-MeV neutrons with ≤100 mGy was determined. The neutron irradiations were made at the Neutron exposure Accelerator System for Biological Effect Experiments (NASBEE) facility in the National Institute of Radiological Sciences (NIRS), Chiba, Japan. A total of 10 neutron doses ranging from 0.6 to 100 mGy were employed (with a gamma-ray contribution of 14% to the total dose), and the biological effects were studied through quantification of apoptosis at 25 hpf. The responses for neutron doses of 10, 20, 25, and 50 mGy approximately fitted on a straight line, while those for neutron doses of 0.6, 1 and 2.5 mGy exhibited neutron hormetic effects. As such, hormetic responses were generically developed by different kinds of ionizing radiations with different linear energy transfer (LET) values. The responses for neutron doses of 70 and 100 mGy were significantly below the lower 95% confidence band of the best-fit line, which strongly suggested the presence of gamma-ray hormesis. - Highlights: • Neutron dose response was determined for embryos of the zebrafish, Danio rerio. • Neutron doses of 0.6, 1 and 2.5 mGy led to neutron hormetic effects. • Neutron doses of 70 and 100 mGy accompanied by gamma rays led to gamma-ray hormesis

  18. In vitro and in vivo effects of low dose HTO contamination modulated by dose rate

    International Nuclear Information System (INIS)

    Petcu, I.; Savu, D.; Moisoi, N.; Koeteles, G.J.

    1997-01-01

    The experiment performed in vitro intended to examine whether an adaptive response could be elicited on lymphocytes by low-level contamination of whole blood with tritiated water and if the modification of the dose rate has any influence on it. Lymphocytes pre-exposed to 3 HOH (0.2 - 6.6 MBq/ml) and subsequently irradiated with I Gy γ-rays showed micronuclei frequency significantly lower (40% - 45%) than the expected member (sum of the yields induced by 3 HOH and γ-rays separately). The degree of the radioresistance induced by HTO pre-treatments became higher with decreasing dose-rate for a rather similar total adapting dose. In vivo, the aim of the study was to investigate if different dose rates are inducing modulation of the lipid peroxidation level and of the thymidine uptake in different tissues of animals contaminated by HTO ingestion. The total doses varied between 5 and 20 cGy and were delivered as chronic (100 days) or acute contamination (5 days). It was observed that only doses about 20 cGy caused a dose-rate dependent increase of the lipid peroxidation level in the tissues of small intestine, kidney and spleen. Both chronic and acute contamination did produce reduced incorporation of thymidine in the cells of bone marrow. The most effective decrease of thymidine uptake was induced by the acute contamination in the lower dose domain (approx. 5 cGy). Our hypothesis is that in this dose domain the modification of thymidine uptake could be due to changes at the level of membrane transport. (author)

  19. Effect of low-dose valsartan on proteinuria in normotensive immunoglobulin A nephropathy with minimal proteinuria: a randomized trial.

    Science.gov (United States)

    Jo, Young-Il; Na, Ha-Young; Moon, Ju-Young; Han, Sang-Woong; Yang, Dong-Ho; Lee, Sang-Ho; Park, Hyeong-Cheon; Choi, Hoon-Young; Lim, So-Dug; Kie, Jeong-Hae; Lee, Yong-Kyu; Shin, Sug-Kyun

    2016-03-01

    Immunoglobulin A nephropathy (IgAN) is a generally progressive disease, even in patients with favorable prognostic features. In this study, we aimed to investigate the antiproteinuric effect and tolerability of low-dose valsartan (an angiotensin II receptor blocker) therapy in normotensive IgAN patients with minimal proteinuria of less than 0.5 to 1.0 g/day. Normotensive IgAN patients, who had persistent proteinuria with a spot urine protein-to-creatinine ratio of 0.3 to 1.0 mg/mg creatinine, were recruited from five hospitals and randomly assigned to either 40 mg of valsartan as the low-dose group or 80 mg of valsartan as the regular-dose group. Clinical and laboratory data were collected at baseline, and at 4, 8, 12, and 24 weeks after valsartan therapy. Forty-three patients (low-dose group, n = 23; regular-dose group, n = 20) were enrolled in the study. Proteinuria decreased significantly not only in the regular-dose group but also in the low-dose group. The change in urine protein-to-creatinine ratio at week 24 was -41.3% ± 26.1% (p valsartan can significantly reduce proteinuria without causing any intolerability in normotensive IgAN patients with minimal proteinuria.

  20. 137Cs and 210Po dose assessment due to consumption of red sea coral reef fishes collected from the local market (Sudan)

    International Nuclear Information System (INIS)

    Hassona, R. K.; Sam, A. K.; Sirelkhatim, D. A.; Osman, O. I.; Larosa, J.

    2004-12-01

    Assessment of committed effective dose (CED) due to consumption of marine fishes (Red Sea) was performed in 33 different marine fish samples collected from the local market at Port Sudan and classified according to their feeding habits into three categories: carnivores, herbivores and omnivores. Activity concentration of 2 10P o and 1 37C s were determined and were found to range between 0.25 to 6.42 (carnivores), 0.7-5 (omnivores) and 1.5-3.8 (herbivores) Bq/Kg fresh w. For 210 Po and 0.1 to 0.46 (carnivores), 0.09 to 0.35 (omnivores) and 0.09 to 0.32 (herbivores) Bq/kg fresh w. For 1 37C s which are several times lower than those of 2 10P o. Appropriate conversion factors were used to derive the CED which was found to be 0.012, 0.01 and 0.01 (μSv/y) in carnivores, omnivores and herbivores, respectively for 137 Cs this contributes about 0.4% of the total dose. While for 210 Po, it was found to be 3.47, 4.81 and 4.14 (μSv/y) in carnivores, omnivores and herbivores, respectively which represents 99.6% of the total dose. The results of CED suggest that the dose received by Sudanese population from the consumption of marine fishes is rather small and the contribution of 13 '7Cs is negligible compared to 210 Po.(Author)

  1. Methods of determining the effective dose in dental radiology

    International Nuclear Information System (INIS)

    Thilander-Klang, A.; Helmrot, E.

    2010-01-01

    A wide variety of X-ray equipment is used today in dental radiology, including intra-oral, ortho-pan-tomographic, cephalo-metric, cone-beam computed tomography (CBCT) and computed tomography (CT). This raises the question of how the radiation risks resulting from different kinds of examinations should be compared. The risk to the patient is usually expressed in terms of effective dose. However, it is difficult to determine its reliability, and it is difficult to make comparisons, especially when different modalities are used. The classification of the new CBCT units is also problematic as they are sometimes classified as CT units. This will lead to problems in choosing the best dosimetric method, especially when the examination geometry resembles more on an ordinary ortho-pan-tomographic examination, as the axis of rotation is not at the centre of the patient, and small radiation field sizes are used. The purpose of this study was to present different methods for the estimation of the effective dose from the equipment currently used in dental radiology, and to discuss their limitations. The methods are compared based on commonly used measurable and computable dose quantities, and their reliability in the estimation of the effective dose. (authors)

  2. Committed effective dose determination in southern Brazilian cereal flours.

    Science.gov (United States)

    Scheibel, V; Appoloni, C R

    2013-01-01

    The health impact of radionuclide ingestion from foodstuffs was evaluated by the committed effective doses determined in eight commercial samples of South-Brazilian cereal flours (soy, wheat, cornmeal, cassava, rye, oat, barley and rice flours). The radioactivity traces of (228)Th, (228)Ra, (226)Ra, (40)K, (7)Be and (137)Cs were measured by gamma-ray spectrometry employing an HPGe detector of 66 % relative efficiency. The efficiency curve has taken into account the differences in densities and chemical composition between the matrix and the certified sample. The highest concentration levels of (228)Th and (40)K were 3.5±0.4 and 1469±17 Bq kg(-1) for soy flour, respectively, within the 95 % confidence level. The lower limit of detection for (137)Cs ranged from 0.04 to 0.4 Bq kg(-1). The highest committed effective dose was 0.36 μSv.y(-1) for (228)Ra in cassava flour (adults). All committed effective doses determined at the present work were lower than the International Atomic Energy Agency dose limit of 1 mSv.y(-1), to the public exposure.

  3. Committed effective dose determination in southern Brazilian cereal flours

    International Nuclear Information System (INIS)

    Scheibel, V.; Appoloni, C. R.

    2013-01-01

    The health impact of radionuclide ingestion from foodstuffs was evaluated by the committed effective doses determined in eight commercial samples of South-Brazilian cereal flours (soy, wheat, cornmeal, cassava, rye, oat, barley and rice flours). The radioactivity traces of 228 Th, 228 Ra, 226 Ra, 40 K, 7 Be and 137 Cs were measured by gamma-ray spectrometry employing an HPGe detector of 66 % relative efficiency. The efficiency curve has taken into account the differences in densities and chemical composition between the matrix and the certified sample. The highest concentration levels of 228 Th and 40 K were 3.5±0.4 and 1469±17 Bq kg -1 for soy flour, respectively, within the 95 % confidence level. The lower limit of detection for 137 Cs ranged from 0.04 to 0.4 Bq kg -1 . The highest committed effective dose was 0.36 μSv.y -1 for 228 Ra in cassava flour (adults). All committed effective doses determined at the present work were lower than the International Atomic Energy Agency dose limit of 1 mSv.y -1 , to the public exposure. (authors)

  4. Monte Carlo Calculated Effective Dose to Teenage Girls from Computed Tomography Examinations

    International Nuclear Information System (INIS)

    Caon, M.; Bibbo, G.; Pattison, J.

    2000-01-01

    Effective doses from CT to paediatric patients are not common in the literature. This article reports some effective doses to teenage girls from CT examinations. The voxel computational model ADELAIDE, representative of a 14-year-old girl, was scaled in size by ±5% to represent also 11-12-year-old and 16-year-old girls. The EGS4 Monte Carlo code was used to calculate the effective dose from chest, abdomen and whole torso CT examinations to the three version of ADELAIDE using a 120 kV spectrum. For the whole torso CT examination, in order of increasing model size, the effective doses were 9.0, 8.2 and 7.8 mSv per 100 mA.s. Data are presented that allow the estimation of effective dose from CT examinations of the torso for girls between the ages of 11 and 16. (author)

  5. The Effects of Pretreatment with Various Doses of L-Arginine on Cisplatin-Induced Nephropathy of Male Rats

    Directory of Open Access Journals (Sweden)

    B Rasoulian

    2016-09-01

    Full Text Available Introduction: Cisplatin is a widely used anti-cancer drug, which its application is limited by nephrotoxicity. In this study, the effect of pretreatment with different l-arginine doses on Cisplatin-induced renal functional injury was investigated. Methods: 63 male rats were divided into 7 groups: In groups 3, 4, 5 and 6, 60 min before the Cisplatin injection (5mg/kg; L-Arginine with doses of 50,100,200 or 400mg/kg was injected, respectively. In group7, normal saline was injected before Cisplatin administration. In groups 1 and 2, normal saline was injected instead of Cisplatin. In group 2, 60min before normal saline injection, 400mg/kg L-Arginine was administered and in group1, instead of L-arginine, normal saline was injected too. Injections were intraperitoneal. 72h after Cisplatin injection, blood sampling and plasma separation were done. Urine sample was collected 24 hours before blood sampling by metabolic cage. The mean of plasma urea and creatinine levels and creatinine clearance (ml/day.kg and fractional excretion of Na (FENa, % were compared among different groups as renal functional parameters. Results: In comparison to group 7, L-arginine injection in a dose of 400mg/kg led to significant amelioration of all parameters. 200 mg/kg L-arginine administration led to significant decrease in plasma urea level and FENa. 100mg/kg L-arginine caused significant improvement in fractional excretion of sodium. L-arginine injection with 50mg/kg dose, significantly ameliorate all renal function tests instead of creatinine clearance. Conclusion: Pretreatment with L-arginine administration with 400 or 50 mg/kg doses, respectively, had the highest effect on reducing Cisplatin-induced nephropathy. L-arginine injection with intermediate doses i.e. 200 or 100 mg/kg had less effect in reducing Cisplatin-induced nephropathy and it needs more investigations.

  6. Effective dose equivalents from external radiation due to Chernobyl accident

    International Nuclear Information System (INIS)

    Erkin, V.G.; Debedev, O.V.; Balonov, M.I.; Parkhomenko, V.I.

    1992-01-01

    Summarized data on measurements of individual dose of external γ-sources in 1987-1990 of population of western areas of Bryansk region were presented. Type of distribution of effective dose equivalent, its significance for various professional and social groups of population depending on the type of the house was discussed. Dependences connecting surface soil activity in the populated locality with average dose of external radiation sources were presented. Tendency of dose variation in 1987-1990 was shown

  7. Radiation dose effects, hardening of electronic components

    International Nuclear Information System (INIS)

    Dupont-Nivet, E.

    1991-01-01

    This course reviews the mechanism of interaction between ionizing radiation and a silicon oxide type dielectric, in particular the effect of electron-hole pairs creation in the material. Then effects of cumulated dose on electronic components and especially in MOS technology are examined. Finally methods hardening of these components are exposed. 93 refs

  8. Using smartphone as a motion detector to collect time-microenvironment data for estimating the inhalation dose.

    Science.gov (United States)

    Hoi, Tran Xuan; Phuong, Huynh Truc; Van Hung, Nguyen

    2016-09-01

    During the production of iodine-131 from neutron irradiated tellurium dioxide by the dry distillation, a considerable amount of (131)I vapor is dispersed to the indoor air. People who routinely work at the production area may result in a significant risk of exposure to chronic intake by inhaled (131)I. This study aims to estimate the inhalation dose for individuals manipulating the (131)I at a radioisotope production. By using an application installed on smartphones, we collected the time-microenvironment data spent by a radiation group during work days in 2015. Simultaneously, we used a portable air sampler combined with radioiodine cartridges for grabbing the indoor air samples and then the daily averaged (131)I concentration was calculated. Finally, the time-microenvironment data jointed with the concentration to estimate the inhalation dose for the workers. The result showed that most of the workers had the annual internal dose in 1÷6mSv. We concluded that using smartphone as a motion detector is a possible and reliable way instead of the questionnaires, diary or GPS-based method. It is, however, only suitable for monitoring on fixed indoor environments and limited the targeted people. Copyright © 2016 Elsevier Ltd. All rights reserved.

  9. Maximizing the biological effect of proton dose delivered with scanned beams via inhomogeneous daily dose distributions

    Energy Technology Data Exchange (ETDEWEB)

    Zeng Chuan; Giantsoudi, Drosoula; Grassberger, Clemens; Goldberg, Saveli; Niemierko, Andrzej; Paganetti, Harald; Efstathiou, Jason A.; Trofimov, Alexei [Department of Radiation Oncology, Massachusetts General Hospital and Harvard Medical School, Boston, Massachusetts 02114 (United States)

    2013-05-15

    Purpose: Biological effect of radiation can be enhanced with hypofractionation, localized dose escalation, and, in particle therapy, with optimized distribution of linear energy transfer (LET). The authors describe a method to construct inhomogeneous fractional dose (IFD) distributions, and evaluate the potential gain in the therapeutic effect from their delivery in proton therapy delivered by pencil beam scanning. Methods: For 13 cases of prostate cancer, the authors considered hypofractionated courses of 60 Gy delivered in 20 fractions. (All doses denoted in Gy include the proton's mean relative biological effectiveness (RBE) of 1.1.) Two types of plans were optimized using two opposed lateral beams to deliver a uniform dose of 3 Gy per fraction to the target by scanning: (1) in conventional full-target plans (FTP), each beam irradiated the entire gland, (2) in split-target plans (STP), beams irradiated only the respective proximal hemispheres (prostate split sagittally). Inverse planning yielded intensity maps, in which discrete position control points of the scanned beam (spots) were assigned optimized intensity values. FTP plans preferentially required a higher intensity of spots in the distal part of the target, while STP, by design, employed proximal spots. To evaluate the utility of IFD delivery, IFD plans were generated by rearranging the spot intensities from FTP or STP intensity maps, separately as well as combined using a variety of mixing weights. IFD courses were designed so that, in alternating fractions, one of the hemispheres of the prostate would receive a dose boost and the other receive a lower dose, while the total physical dose from the IFD course was roughly uniform across the prostate. IFD plans were normalized so that the equivalent uniform dose (EUD) of rectum and bladder did not increase, compared to the baseline FTP plan, which irradiated the prostate uniformly in every fraction. An EUD-based model was then applied to estimate tumor

  10. Maximizing the biological effect of proton dose delivered with scanned beams via inhomogeneous daily dose distributions

    International Nuclear Information System (INIS)

    Zeng Chuan; Giantsoudi, Drosoula; Grassberger, Clemens; Goldberg, Saveli; Niemierko, Andrzej; Paganetti, Harald; Efstathiou, Jason A.; Trofimov, Alexei

    2013-01-01

    Purpose: Biological effect of radiation can be enhanced with hypofractionation, localized dose escalation, and, in particle therapy, with optimized distribution of linear energy transfer (LET). The authors describe a method to construct inhomogeneous fractional dose (IFD) distributions, and evaluate the potential gain in the therapeutic effect from their delivery in proton therapy delivered by pencil beam scanning. Methods: For 13 cases of prostate cancer, the authors considered hypofractionated courses of 60 Gy delivered in 20 fractions. (All doses denoted in Gy include the proton's mean relative biological effectiveness (RBE) of 1.1.) Two types of plans were optimized using two opposed lateral beams to deliver a uniform dose of 3 Gy per fraction to the target by scanning: (1) in conventional full-target plans (FTP), each beam irradiated the entire gland, (2) in split-target plans (STP), beams irradiated only the respective proximal hemispheres (prostate split sagittally). Inverse planning yielded intensity maps, in which discrete position control points of the scanned beam (spots) were assigned optimized intensity values. FTP plans preferentially required a higher intensity of spots in the distal part of the target, while STP, by design, employed proximal spots. To evaluate the utility of IFD delivery, IFD plans were generated by rearranging the spot intensities from FTP or STP intensity maps, separately as well as combined using a variety of mixing weights. IFD courses were designed so that, in alternating fractions, one of the hemispheres of the prostate would receive a dose boost and the other receive a lower dose, while the total physical dose from the IFD course was roughly uniform across the prostate. IFD plans were normalized so that the equivalent uniform dose (EUD) of rectum and bladder did not increase, compared to the baseline FTP plan, which irradiated the prostate uniformly in every fraction. An EUD-based model was then applied to estimate tumor

  11. Maximizing the biological effect of proton dose delivered with scanned beams via inhomogeneous daily dose distributions.

    Science.gov (United States)

    Zeng, Chuan; Giantsoudi, Drosoula; Grassberger, Clemens; Goldberg, Saveli; Niemierko, Andrzej; Paganetti, Harald; Efstathiou, Jason A; Trofimov, Alexei

    2013-05-01

    Biological effect of radiation can be enhanced with hypofractionation, localized dose escalation, and, in particle therapy, with optimized distribution of linear energy transfer (LET). The authors describe a method to construct inhomogeneous fractional dose (IFD) distributions, and evaluate the potential gain in the therapeutic effect from their delivery in proton therapy delivered by pencil beam scanning. For 13 cases of prostate cancer, the authors considered hypofractionated courses of 60 Gy delivered in 20 fractions. (All doses denoted in Gy include the proton's mean relative biological effectiveness (RBE) of 1.1.) Two types of plans were optimized using two opposed lateral beams to deliver a uniform dose of 3 Gy per fraction to the target by scanning: (1) in conventional full-target plans (FTP), each beam irradiated the entire gland, (2) in split-target plans (STP), beams irradiated only the respective proximal hemispheres (prostate split sagittally). Inverse planning yielded intensity maps, in which discrete position control points of the scanned beam (spots) were assigned optimized intensity values. FTP plans preferentially required a higher intensity of spots in the distal part of the target, while STP, by design, employed proximal spots. To evaluate the utility of IFD delivery, IFD plans were generated by rearranging the spot intensities from FTP or STP intensity maps, separately as well as combined using a variety of mixing weights. IFD courses were designed so that, in alternating fractions, one of the hemispheres of the prostate would receive a dose boost and the other receive a lower dose, while the total physical dose from the IFD course was roughly uniform across the prostate. IFD plans were normalized so that the equivalent uniform dose (EUD) of rectum and bladder did not increase, compared to the baseline FTP plan, which irradiated the prostate uniformly in every fraction. An EUD-based model was then applied to estimate tumor control probability

  12. Effects of low dose radiation and epigenetic regulation

    International Nuclear Information System (INIS)

    Jiao Benzheng; Ma Shumei; Yi Heqing; Kong Dejuan; Zhao Guangtong; Gao Lin; Liu Xiaodong

    2010-01-01

    Purpose: To conclude the relationship between epigenetics regulation and radiation responses, especially in low-dose area. Methods: The literature was examined for papers related to the topics of DNA methylation, histone modifications, chromatin remodeling and non-coding RNA modulation in low-dose radiation responses. Results: DNA methylation and radiation can regulate reciprocally, especially in low-dose radiation responses. The relationship between histone methylation and radiation mainly exists in the high-dose radiation area; histone deacetylase (HDAC) inhibitors show a promising application to enhance radiation sensitivity, no matter whether in low-dose or high-dose areas; the connection between γ-H2AX and LDR has been remained unknown, although γ-H2AX has been shown no radiation sensitivities with 1-15 Gy irradiation; histone ubiquitination play an important role in DNA damage repair mechanism. Moreover, chromatin remodeling has an integral role in DSB repair and the chromatin response, in general, may be precede DNA end resection. Finally, the effect of radiation on miRNA expression seems to vary according to cell type, radiation dose, and post-irradiation time point. Conclusion: Although the advance of epigenetic regulation on radiation responses, which we are managing to elucidate in this review, has been concluded, there are many questions and blind blots deserved to investigated, especially in low-dose radiation area. However, as progress on epigenetics, we believe that many new elements will be identified in the low-dose radiation responses which may put new sights into the mechanisms of radiation responses and radiotherapy. (authors)

  13. Dietary toxicity of field-contaminated invertebrates to marine fish: effects of metal doses and subcellular metal distribution.

    Science.gov (United States)

    Dang, Fei; Rainbow, Philip S; Wang, Wen-Xiong

    2012-09-15

    There is growing awareness of the toxicological effects of metal-contaminated invertebrate diets on the health of fish populations in metal-contaminated habitats, yet the mechanisms underlying metal bioaccumulation and toxicity are complex. In the present study, marine fish Terapon jurbua terepon were fed a commercial diet supplemented with specimens of the polychaete Nereis diversicolor or the clam Scrobicularia plana, collected from four metal-impacted estuaries (Tavy, Restronguet Creek, West Looe, Gannel) in southwest England, as environmentally realistic metal sources. A comparative toxicological evaluation of both invertebrates showed that fish fed S. plana for 21 d exhibited evident mortality compared to those fed N. diversicolor. Furthermore, a spatial effect on mortality was observed. Differences in metal doses rather than subcellular metal distributions between N. diversicolor and S. plana appeared to be the cause of such different mortalities. Partial least squares regression was used to evaluate the statistical relationship between multiple-metal doses and fish mortality, revealing that Pb, Fe, Cd and Zn in field-collected invertebrates co-varied most strongly with the observed mortality. This study provides a step toward exploring the underlying mechanism of dietary toxicity and identifying the potential causality in complex metal mixture exposures in the field. Copyright © 2012 Elsevier B.V. All rights reserved.

  14. Influences of gas stream conditions on efficiency of tritiated moisture collection with P2O5-desiccant and isotope effect

    International Nuclear Information System (INIS)

    Kotoh, Kenji; Miura, Katsuya; Kashio, Yousuke; Nishikawa, Masabumi

    1991-01-01

    A method was proposed previously for collection and measurement of tritiated moisture in gas stream using P 2 O 5 -desiccant. Influences of the gas humidity, the gas flow rate and the distance between gas nozzle and P 2 O 5 -desiccant layer surface on the moisture collection efficiency have been examined through experiments, and the isotope effect on the collection has been investigated. The collection efficiency is the ratio of collected to supplied moisture, and the moisture supplying rate is in proportion to the humidity and flow rate of feed gas. The experiments show that; the collection efficiency dose not depend on the gas humidity, but is affected by the gas flow rate and by the nozzle-layer distance. The effects of the flow rate and the nozzle position are related to the mass transfer distance from the bulk of gas stream to the desiccant layer surface in the collection cell. The moisture collecting rate is promoted by the approach of the gas stream to the layer surface. An expression of effective separation factor has been derived to explain the isotope effect on the moisture collection. Experimental data distribution of the separation factor have been reasonably simulated by the analysis. (author)

  15. Proton dose distribution measurements using a MOSFET detector with a simple dose-weighted correction method for LET effects.

    Science.gov (United States)

    Kohno, Ryosuke; Hotta, Kenji; Matsuura, Taeko; Matsubara, Kana; Nishioka, Shie; Nishio, Teiji; Kawashima, Mitsuhiko; Ogino, Takashi

    2011-04-04

    We experimentally evaluated the proton beam dose reproducibility, sensitivity, angular dependence and depth-dose relationships for a new Metal Oxide Semiconductor Field Effect Transistor (MOSFET) detector. The detector was fabricated with a thinner oxide layer and was operated at high-bias voltages. In order to accurately measure dose distributions, we developed a practical method for correcting the MOSFET response to proton beams. The detector was tested by examining lateral dose profiles formed by protons passing through an L-shaped bolus. The dose reproducibility, angular dependence and depth-dose response were evaluated using a 190 MeV proton beam. Depth-output curves produced using the MOSFET detectors were compared with results obtained using an ionization chamber (IC). Since accurate measurements of proton dose distribution require correction for LET effects, we developed a simple dose-weighted correction method. The correction factors were determined as a function of proton penetration depth, or residual range. The residual proton range at each measurement point was calculated using the pencil beam algorithm. Lateral measurements in a phantom were obtained for pristine and SOBP beams. The reproducibility of the MOSFET detector was within 2%, and the angular dependence was less than 9%. The detector exhibited a good response at the Bragg peak (0.74 relative to the IC detector). For dose distributions resulting from protons passing through an L-shaped bolus, the corrected MOSFET dose agreed well with the IC results. Absolute proton dosimetry can be performed using MOSFET detectors to a precision of about 3% (1 sigma). A thinner oxide layer thickness improved the LET in proton dosimetry. By employing correction methods for LET dependence, it is possible to measure absolute proton dose using MOSFET detectors.

  16. Does iterative reconstruction lower CT radiation dose: evaluation of 15,000 examinations.

    Directory of Open Access Journals (Sweden)

    Peter B Noël

    Full Text Available PURPOSE: Evaluation of 15,000 computed tomography (CT examinations to investigate if iterative reconstruction (IR reduces sustainably radiation exposure. METHOD AND MATERIALS: Information from 15,000 CT examinations was collected, including all aspects of the exams such as scan parameter, patient information, and reconstruction instructions. The examinations were acquired between January 2010 and December 2012, while after 15 months a first generation IR algorithm was installed. To collect the necessary information from PACS, RIS, MPPS and structured reports a Dose Monitoring System was developed. To harvest all possible information an optical character recognition system was integrated, for example to collect information from the screenshot CT-dose report. The tool transfers all data to a database for further processing such as the calculation of effective dose and organ doses. To evaluate if IR provides a sustainable dose reduction, the effective dose values were statistically analyzed with respect to protocol type, diagnostic indication, and patient population. RESULTS: IR has the potential to reduce radiation dose significantly. Before clinical introduction of IR the average effective dose was 10.1±7.8mSv and with IR 8.9±7.1mSv (p*=0.01. Especially in CTA, with the possibility to use kV reduction protocols, such as in aortic CTAs (before IR: average14.2±7.8mSv; median11.4mSv /with IR:average9.9±7.4mSv; median7.4mSv, or pulmonary CTAs (before IR: average9.7±6.2mSV; median7.7mSv /with IR: average6.4±4.7mSv; median4.8mSv the dose reduction effect is significant(p*=0.01. On the contrary for unenhanced low-dose scans of the cranial (for example sinuses the reduction is not significant (before IR:average6.6±5.8mSv; median3.9mSv/with IR:average6.0±3.1mSV; median3.2mSv. CONCLUSION: The dose aspect remains a priority in CT research. Iterative reconstruction algorithms reduce sustainably and significantly radiation dose in the clinical routine

  17. The researches on the effects of low doses irradiation

    International Nuclear Information System (INIS)

    2009-02-01

    All research conducted as part of 'Risc-Rad' and those conducted by actors in international programs on low doses allow progress in understanding mechanisms of carcinogenesis associated with irradiation. The data do not question the use in radiation protection, risk estimation models based on a linear increase of the risk with the dose of radiation. Nevertheless, they show that the nature of biological responses induced by low doses of radiation has differences with the responses induced by high doses of radiation. They also show the diversity of effects/dose relationships as the mechanism observed and the importance of genetic predisposition in the individual sensitivity to low doses of radiation. It is therefore essential to continue to bring new data to better understand the complex biological effects and their impact on the establishment of radiation protection standards. In addition, the results have often been at the cellular level. The diversity of responses induced by radiations is also a function of cell types observed, the aging of cells and tissue organization. It is essential to strengthen researches at the tissue and body level, involving in vitro and in vivo approaches while testing the hypothesis in epidemiology with a global approach to systems biology. Over the past four years, the collaboration between partners of 'Risc-Rad' using experimental biology approaches and those using mathematical modeling techniques aimed at developing a new model describing the carcinogenesis induced by low radiation doses. On an other hand, The High level expert group on European low dose risk research (H.L.E.G.) develop programmes in the area of low dose irradiation (Germany, Finland, France, Italy and United Kingdom). It proposed a structure of trans national government called M.E.L.O.D.I. ( multidisciplinary european low dose initiative). Its objective is to structure and integrate European research by gathering around a common programme of multidisciplinary

  18. Internal doses to Ukrainian populations using Dnieper River water

    International Nuclear Information System (INIS)

    Berkovski, V.; Ratia, G.; Nasvit, O.

    1996-01-01

    The dynamics of internal doses from 137 Cs and 90 Sr as a consequence of the use of Dnieper River water were calculated. Local peculiarities of municipal tap, irrigation, and fish consumption in the Ukraine were considered. The dynamics of 90 Sr accumulation in human bone as a result of the use of Dnieper water is simulated. The dose predictions are based on de facto data and the stochastic forecast of radionuclide concentrations in Dnieper reservoirs. A large array of statistical data on the age-structures of exposed populations, food consumption rate, agricultural production, fish contamination, and site-specific parameters were used. Exposures are estimated for 12 regions of the Dnieper basin and the Crimea Republic. The maximal individual annual committed effective doses are 1.7 x 10 -5 and 2.7 x 10 -5 Sv from 90 Sr and 137 Cs, respectively, due to the use of water in 1986 by members of the population in the Kievska region. Commercial fishermen on the Kievska reservoir, who consumed 360 kg y -1 of fish in 1986, received 4.7 x 10 -4 and 5 x 10 -3 Sv from 90 Sr and 137 Cs, respectively. The contributions to the collective (over 70 6) effective dose of irrigation, municipal tap water, and fish consumption for members of the general public, respectively, are 18%, 43%,39% in the Kievska region; 8%,25%,67% in the Poltavska region; 50% 50%, 0% (no Dnieper fish consumed) in the Crimea Republic. The predicted contribution of 90 Sr to collective dose resulting from the use of water is 80%. The collective dose to the population of the Dnieper regions (32.5 million people) is 3,000 person-Sv, due to the use of water. 14 refs., 12 figs., 2 tabs

  19. Effects of dose fractionation on the response of alanine dosimetry

    International Nuclear Information System (INIS)

    Lundahl, Brad; Logar, John; Desrosiers, Marc; Puhl, James

    2014-01-01

    Alanine dosimetry is well established as a transfer standard and is becoming more prevalently used in routine dosimetry systems for radiation processing. Many routine measurement applications in radiation processing involve absorbed dose measurements resulting from fractioned exposures to ionizing radiation. Fractioning of absorbed dose is identified as an influence quantity (ISO/ASTM, 2013). This paper reports on study results of absorbed dose fractioning characteristics of alanine for gamma and high energy electron beam radiation sources. The results of this study indicate a radiation response difference due to absorbed dose fractioning in response can be observed after four fractionations for high-energy electron beams and no difference up to seven fractions for gamma rays using an ANOVA evaluation method. - Highlights: • Fractioning effects signaled in electron beam using an ANOVA at 6 equal increments. • Fractioning effects not signaled in gamma using an ANOVA up to 7 equal increments. • Insensitivity of alanine to dose fractioning indicates nominal impact on calibration

  20. Studies of health effects of low dose radiation and its application to medicare

    International Nuclear Information System (INIS)

    Yamaoka, Kiyonori; Ishida, Kenji; Iwasaki, Toshiyasu; Koana, Takao; Magae, Junji; Watanabe, Masami; Sakamoto, Kiyohiko

    2008-01-01

    The articles contain following 7 topics of low dose radiation effects. Studies of Health Effects of Low dose Radiation and Its Application to Medicare'', describes the indication of Rn therapy and investigations of its usefulness mechanism mainly in Misasa Spa, Okayama Pref. ''Challenges for the Paradigm Shift (CRIEPI Studies)'', introduces studies against the paradigm that radiation dose is linearly and proportionally hazardous. ''Studies of High Background Radiation Area (CRIEPI Studies)'', describes global HBRA studies on chromosome affection and effect of smoking in HBRA. ''Is the Radiation Effect on Man Proportional to Dose? (CRIEPI Studies)'', describes studies of immature sperm irradiated at low dose against Linear-Non-threshold Theory (LNT) hypothesis. ''Induction of Radiation Resistance by Low Dose Radiation and Assessment of Its Effect in Models of Human Diseases (CRIEPI Studies)'', explains the adoptive response in radiation effect, suppression of carcinogenesis and immune regulation by previous low dose radiation in the mouse, and improvement of diabetes in the db/db mouse. ''Modulation of Biological Effects of Low Dose Radiation: Adoptive Response, Bystander Effect, Genetic Instability and Radiation Hormesis'', summarizes findings of each item. ''Cancer Treatment with Low dose Radiation to the Whole Body'', describes basic studies in the mouse tumor in relation to suppression of carcinogenesis and metastasis, immune activation and treatment, and successful clinical studies in patients with ovary, colon cancers and malignant lymphoma where survival has been significantly improved: a base of recent European Organization for Research and Treatment of Cancer (EORTC) clinical trials. The mechanism is essentially based on immune activation of patients to cure the disease. (R.T.)

  1. Geographical representation of the European populations with a view to the assessment of collective doses

    International Nuclear Information System (INIS)

    Garnier, A.; Sauve, A.; Madelmont, C.

    1980-01-01

    Demographical data are very important in assessing health consequences of the siting of nuclear plants. In addition to a detailed description of the distribution of population living in the neighbourhood of every site, a less definite representation of the population as a whole is needed to assess the consequences of the long-range transport of pollutants within or outside the national boundaries, in order to determine the collective doses according to the concepts of the ICRP recommendations. For this purpose, the census data of the nine countries of the European Community have been collected. They are presented in two forms: either by communes or following a more or less close-meshed grid. The points have been defined by their geographical coordinates. After merging the informations, the demographic data were classified according to the geographical coordinates. One of them is a distribution programme of the population in the meshes of an European grid, some examples of which are shown. (H.K.)

  2. An efficient dose-compensation method for proximity effect correction

    International Nuclear Information System (INIS)

    Wang Ying; Han Weihua; Yang Xiang; Zhang Yang; Yang Fuhua; Zhang Renping

    2010-01-01

    A novel simple dose-compensation method is developed for proximity effect correction in electron-beam lithography. The sizes of exposed patterns depend on dose factors while other exposure parameters (including accelerate voltage, resist thickness, exposing step size, substrate material, and so on) remain constant. This method is based on two reasonable assumptions in the evaluation of the compensated dose factor: one is that the relation between dose factors and circle-diameters is linear in the range under consideration; the other is that the compensated dose factor is only affected by the nearest neighbors for simplicity. Four-layer-hexagon photonic crystal structures were fabricated as test patterns to demonstrate this method. Compared to the uncorrected structures, the homogeneity of the corrected hole-size in photonic crystal structures was clearly improved. (semiconductor technology)

  3. Modifying effect of low dose irradiation

    International Nuclear Information System (INIS)

    Kalendo, G.S.

    1989-01-01

    It is shown that irradiation of Hela cells with stimulating doses of 0,1 Gy changes the cells' response to the subsequent radiation effect of greater value: instead of DNA synthesis inhibition stimulation takes place. Modifying effect of preliminary irradiation with 0,1 Gy manifests it self only in case if there is a certain time interval not less than 3 minutes and not more than 10 minutes (3-5 minutes is optimal interval). Data on modifying effect with 0,1 Gy at subcellular and cellular-population levels are presented. 21 refs.; 6 figs

  4. Calculation of age-dependent effective doses for external exposure using the MCNP code

    International Nuclear Information System (INIS)

    Hung, Tran Van

    2013-01-01

    Age-dependent effective dose for external exposure to photons uniformly distributed in air were calculated. Firstly, organ doses were calculated with a series of age-specific MIRD-5 type phantoms using the Monte Carlo code MCNP. The calculations were performed for mono-energetic photon sources with source energies from 10 keV to 5 MeV and for phantoms of newborn, 1, 5, 10, and 15 years-old and adult. Then, the effective doses to the different age-phantoms from the mono-energetic photon sources were estimated based on the obtained organ doses. From the calculated results, it is shown that the effective doses depend on the body size; the effective doses in younger phantoms are higher than those in the older phantoms, especially below 100 keV. (orig.)

  5. Calculation of age-dependent effective doses for external exposure using the MCNP code

    Energy Technology Data Exchange (ETDEWEB)

    Hung, Tran Van [Research and Development Center for Radiation Technology, ThuDuc, HoChiMinh City (VT)

    2013-07-15

    Age-dependent effective dose for external exposure to photons uniformly distributed in air were calculated. Firstly, organ doses were calculated with a series of age-specific MIRD-5 type phantoms using the Monte Carlo code MCNP. The calculations were performed for mono-energetic photon sources with source energies from 10 keV to 5 MeV and for phantoms of newborn, 1, 5, 10, and 15 years-old and adult. Then, the effective doses to the different age-phantoms from the mono-energetic photon sources were estimated based on the obtained organ doses. From the calculated results, it is shown that the effective doses depend on the body size; the effective doses in younger phantoms are higher than those in the older phantoms, especially below 100 keV. (orig.)

  6. Predicted effects of countermeasures on radiation doses from contaminated food

    International Nuclear Information System (INIS)

    Yamamoto, Hideaki; Nielsen, S.P.; Nielsen, F.

    1993-02-01

    Quantitative assessments of the effects on radiation-dose reductions from nine typical countermeasures against accidental fod contamination have been carried out with dynamic radioecological models. The foodstuffs are assumed to be contaminated with iodine-131, caesium-134 and caesium-137 after a release of radioactive materials from the Ringhals nuclear power station in Sweden resulting from a hypothetical core melt accident. The release of activity of these radionuclides is assumed at 0.07% of the core inventory of the unit 1 reactor (1600 TBq of I-131, 220 TBq of Cs-134 and 190 TBq of Cs-137). Radiation doses are estimated for the 55,000 affected inhabitants along the south-eastern coast of Sweden eating locally produced foodstuffs. The average effective dose equivalent to an individual in the critical group is predicted to be 2.9 mSv from food consumption contaminated with I-131. An accident occurring during winter is estimated to cause average individual doses of 0.32 mSv from Cs-134 and 0.47 mSv from Cs-137, and 9.4 mSv and 6.8 mSv from Cs-134 and Cs-137, respectively, for an accident occurring during summer. Doses from the intake of radioiodine may be reduced by up to a factor of 60 by rejecting contaminated food for 30 days. For the doses from radiocaesium, the largest effect is found form deep ploughing which may reduce the dose by up to a factor of 80. (au) (12 tabs., 6 ills., 19 refs.)

  7. Evaluation of the collective effective dose equivalent of atmospheric discharges in the Rhone valley

    International Nuclear Information System (INIS)

    Le Grand, J.; Despres, A.; Robeau, D.; Bouville, A.

    1982-01-01

    Two models were used to evaluate the integrated atmospheric concentrations: - TALD, a long-range atmospheric transport model which takes account of the actual trajectories of the discharged matter; - a Gaussian plume model which assumes straight-line trajectories defined by the wind at the point of emission. In order to bring out the differences due to the use of the two models the dose equivalents are presented as a function of wind direction at the point of emission and the contributions of the near zone and the further zone are compared. (author)

  8. Can results from animal studies be used to estimate dose or low dose effects in humans

    International Nuclear Information System (INIS)

    Thomas, J.M.; Eberhardt, L.L.

    1981-01-01

    A method has been devised to extrapolate biological equilibrium levels between animal species and subsequently to humans. Our initial premise was based on the observation that radionuclide retention is normally a function of metabolism so that direct or indirect measures could be described by a power law based on body weights of test animal species. However, we found that such interspecies comparisons ought to be based on the coefficient of the power equation rather than on the exponential parameter. The method is illustrated using retention data obtained from five non-ruminant species (including humans) that were fed radionuclides with different properties. It appears that biological equilibrium level for radionuclides in man can be estimated using data from mice, rats, and dogs. The need to extrapolate low-dose effects data obtained from small animals (usually rodents) to humans is not unique to radiation dosimetry or radiation protection problems. Therefore, some quantitative problems connected with estimating low-dose effects from other disciplines have been reviewed, both because of the concern about effects induced by the radionuclide moiety of a radiopharmaceutical and those of the nonradioactive component. The possibility of extrapolating low-dose effects calculated from animal studies to human is discussed

  9. Can results from animal studies be used to estimate dose or low dose effects in humans

    International Nuclear Information System (INIS)

    Thomas, J.M.; Eberhardt, L.L.

    1981-01-01

    We have devised a method to extrapolate biological equilibrium levels between animal species and subsequently to humans. Our initial premise was based on the observation that radionuclide retention is normally a function of metabolism so that direct or indirect measures could be described by a power law based on body weights of test animal species. However, we found that such interspecies comparisons ought to be based on the coefficient of the power equation rather than on the exponential parameter. The method is illustrated using retention data obtained from five non-ruminant species (including humans) that were fed radionuclides with different properties. It appears that biological equilibrium level for radionuclides in man can be estimated using data from mice, rats and dogs. The need to extrapolate low-dose effects data obtained from small animals (usually rodents) to humans is not unique to radiation dosimetry or radiation protection problems. Therefore, researchers have reviewed some quantitative problems connected with estimating low-dose effects from other disciplines, both because of the concern about effects induced by the radionuclide moiety of a radiopharmaceutical and those of the nonradioactive component. The possibility of extrapolating low-dose effects calculated from animal studies to humans is discussed

  10. Using smartphone as a motion detector to collect time-microenvironment data for estimating the inhalation dose

    International Nuclear Information System (INIS)

    Hoi, Tran Xuan; Phuong, Huynh Truc; Van Hung, Nguyen

    2016-01-01

    During the production of iodine-131 from neutron irradiated tellurium dioxide by the dry distillation, a considerable amount of "1"3"1I vapor is dispersed to the indoor air. People who routinely work at the production area may result in a significant risk of exposure to chronic intake by inhaled "1"3"1I. This study aims to estimate the inhalation dose for individuals manipulating the "1"3"1I at a radioisotope production. By using an application installed on smartphones, we collected the time-microenvironment data spent by a radiation group during work days in 2015. Simultaneously, we used a portable air sampler combined with radioiodine cartridges for grabbing the indoor air samples and then the daily averaged "1"3"1I concentration was calculated. Finally, the time-microenvironment data jointed with the concentration to estimate the inhalation dose for the workers. The result showed that most of the workers had the annual internal dose in 1÷6 mSv. We concluded that using smartphone as a motion detector is a possible and reliable way instead of the questionnaires, diary or GPS-based method. It is, however, only suitable for monitoring on fixed indoor environments and limited the targeted people. - Highlights: • We constructed the time-microenvironment patterns with 1-min resolution by using a smartphone application. • Exposure to "1"3"1I at the dry distillation areas may lead to an acute inhalation dose significantly. • Using smartphone as a motion detector in indoor exposure monitoring is a reliable method.

  11. Survey on the frequency of typical X-Ray examinations and estimation of associated population doses in the Republic of Macedonia

    International Nuclear Information System (INIS)

    Gershan, V.; Stikova, E.

    2013-01-01

    Purpose: Medical X-ray exposures have been the largest man-made source of population exposure to ionizing radiation in developed countries for many years. It is therefore important for radiation protection and health care authorities in each country to regularly assess the magnitude and the distribution of this large and increasing source of population exposure. The purpose of this paper is to present results from the survey on the number of typical X-ray examination procedures in the Republic of Macedonia for 2010, the distribution of examination procedures by type per modality for adults and pediatric patients, the annual frequency per 1000 population and the collective effective dose per 1000 population from the X-ray examination procedures performed in the Republic of Macedonia in 2010. Materials and methods: In the beginning of 2011, a survey was initiated in the Republic of Macedonia for collecting data on the number of typical X-ray examination procedures conducted in 2010 as a basis for estimating frequency of these procedures and associated population doses. The survey was initiated within a Dose Data Med project launched by the European Commission to study population doses from medical exposures within the Union. The Republic of Macedonia was invited to participate in this project as a test country. Typical X-ray examination procedures encompass those that are recognized to be the most important for the total population dose, referred to as TOP20 X-ray procedures. The survey was based on a specific questionnaire being prepared and distributed to the 87 X-ray departments in the Republic of Macedonia intended to cover the data for the year of 2010. The data was collected and summarized. Based on data gathered, the total number of examination procedures, annual frequency and their distribution by modality were calculated. Thereafter, the annual collective effective dose per 1000 population for each examination procedure in the TOP20 group and collective

  12. Evaluation of organ doses and specific k effective dose of 64-slice CT thorax examination using an adult anthropomorphic phantom

    International Nuclear Information System (INIS)

    Hashim, S.; Karim, M.K.A.; Bakar, K.A.; Sabarudin, A.; Chin, A.W; Saripan, M.I.; Bradley, D.A.

    2016-01-01

    The magnitude of radiation dose in computed tomography (CT) depends on the scan acquisition parameters, investigated herein using an anthropomorphic phantom (RANDO®) and thermoluminescence dosimeters (TLD). Specific interest was in the organ doses resulting from CT thorax examination, the specific k coefficient for effective dose estimation for particular protocols also being determined. For measurement of doses representing five main organs (thyroid, lung, liver, esophagus and skin), TLD-100 (LiF:Mg, Ti) were inserted into selected holes in a phantom slab. Five CT thorax protocols were investigated, one routine (R1) and four that were modified protocols (R2 to R5). Organ doses were ranked from greatest to least, found to lie in the order: thyroid>skin>lung>liver>breast. The greatest dose, for thyroid at 25 mGy, was that in use of R1 while the lowest, at 8.8 mGy, was in breast tissue using R3. Effective dose (E) was estimated using three standard methods: the International Commission on Radiological Protection (ICRP)-103 recommendation (E103), the computational phantom CT-EXPO (E(CTEXPO)) method, and the dose-length product (DLP) based approach. E103 k factors were constant for all protocols, ~8% less than that of the universal k factor. Due to inconsistency in tube potential and pitch factor the k factors from CTEXPO were found to vary between 0.015 and 0.010 for protocols R3 and R5. With considerable variation between scan acquisition parameters and organ doses, optimization of practice is necessary in order to reduce patient organ dose. - Highlights: • Using TLD-100 dosimeters and a RANDO phantom 5 CT thorax protocol organ doses were assessed. • The specific k coefficient for effective dose estimation of protocols differed with approach. • Organ dose was observed to decrease in the order: thyroid>skin>lung>liver>breast. • E103 k factors were constant for all protocols, lower by ~8% compared to the universal k factor.

  13. Radiation dose and cancer risk to children undergoing skull radiography

    International Nuclear Information System (INIS)

    Mazonakis, Michael; Damilakis, John; Raissaki, Maria; Gourtsoyiannis, Nicholas

    2004-01-01

    Background: Limited data exist in the literature concerning the patient-effective dose from paediatric skull radiography. No information has been provided regarding organ doses, patient dose during PA skull projection, risk of cancer induction and dose to comforters, i.e. individuals supporting children during exposure. Objective: To estimate patient-effective dose, organ doses, lifetime cancer mortality risk to children and radiation dose to comforters associated with skull radiography. Materials and methods: Data were collected from 136 paediatric examinations, including AP, PA and lateral skull radiographs. Entrance-surface dose (ESD) and dose to comforters were measured using thermoluminescent dosimeters. Patients were divided into the following age groups: 0.5-2, 3-7, 8-12 and 13-18 years. The patient-effective dose and corresponding organ doses were calculated using data from the NRPB and Monte Carlo techniques. The risk for fatal cancer induction was assessed using appropriate risk coefficients. Results: For AP, PA and lateral skull radiography, effective dose ranges were 8.8-25.4, 8.2-27.3 and 8.4-22.7 μSv respectively, depending upon the age of the child. For each skull projection, the organs receiving doses above 10 μGy are presented. The number of fatal cancers was found to be less than or equal to 2 per 1 million children undergoing a skull radiograph. The mean radiation dose absorbed by the hands of comforters was 13.4 μGy. Conclusions: The current study provides detailed tabular and graphical data on ESD, effective dose, organ doses and lifetime cancer mortality risk to children associated with AP, PA and lateral skull projections at all patient ages. (orig.)

  14. Dose-rate effects on gamma-induced genetic injury in rat spermatogonia

    International Nuclear Information System (INIS)

    Vyglenov, A.

    1990-01-01

    Data for correlation between the reciprocal translocations (RT) yield in rat germ cells and the doses of 0.5 - 3.0 Gy are presented. A 60 Co source has been used with dose rates of 0.25, 8 x 10 -2 and 7 x 10 -3 Gy/min. The results from the cytogenetic analysis made 6 months after irradiation have shown an increase of the yield with the increase of the dose, which can be described as a linear unthreshold dependence. The dose rate effect is expressed in decrease of mutation frequency. The comparison with earlier author's data from similar experiments for acute irradiation allows to determine the RBE of gamma irradiation at the three dose rates investigated as 0.6, 0.2 and 0.1 respectively. The reported results are connected with the problem of variety specificity of the dose rate effect. 2 figs., 2 tabs., 15 refs

  15. Committed effective dose determination in cereal flours by gamma-ray spectrometry

    International Nuclear Information System (INIS)

    Scheibel, Viviane

    2006-01-01

    The health impact from radionuclides ingestion of foodstuffs was evaluated by the committed effective doses determined in commercial samples of South-Brazilian cereal flours (soy, wheat, corn, manioc, rye, oat, barley and rice flour). The radioactivity traces of 228 Th, 228 Ra, 226 Ra, 40 K, 7 Be and 137 Cs were measured by gamma-ray spectrometry employing a 66% relative efficiency HPGe detector. The energy resolution for the 1332.46 keV line of 60 Co was 2.03 keV. The committed effective doses were calculated with the activities analyzed in the present flour samples, the foodstuff rates of consumption (Brazilian Institute of Geography and Statistics) and the ingestion dose coefficients (International Commission of Radiological Protection). The reliability median activities were verified with χ 2 tests, assuring the fittings quality. The highest concentration levels of 228 Th and 40 K were 3.5 ± 0.4 and 1469 ± 17 Bq.kg -1 for soy flour, respectively, with 95% of confidence level. The lower limit of detection for 137 Cs ranged from 0.04 to 0.4 Bq.kg -1 . The highest committed effective dose was 0.36 μSv.y -1 for 228 Ra in manioc flour (adults). All committed effective doses determined at the present work were lower than the UNSCEAR limits of 140 μSv.y -1 and much lower than the ICRP (1991) limits of 1 mSv.y -1 , for general public. There are few literature references for natural and artificial radionuclides in foodstuffs and mainly for committed effective doses. This work brings the barley flour data, which is not present at the literature and 7 Be data which is not encountered in foodstuffs at the literature, besides all the other flours data information about activities and committed effective doses. (author)

  16. Effect of physiological factors on dose due to organically bound tritium

    International Nuclear Information System (INIS)

    Trivedi, A.

    1998-01-01

    The International Commission on Radiological Protection (ICRP) recommends the understanding of the effect of age, anatomical and physiological data on the doses in order to prescribe dose coefficient for radionuclides. The published data on OBT dose fraction after acute or chronic intakes of HTO are evaluated to examine the variation of OBT dose with the age and physiology of occupational workers. (author)

  17. Verification of an effective dose equivalent model for neutrons

    International Nuclear Information System (INIS)

    Tanner, J.E.; Piper, R.K.; Leonowich, J.A.; Faust, L.G.

    1992-01-01

    Since the effective dose equivalent, based on the weighted sum of organ dose equivalents, is not a directly measurable quantity, it must be estimated with the assistance of computer modelling techniques and a knowledge of the incident radiation field. Although extreme accuracy is not necessary for radiation protection purposes, a few well chosen measurements are required to confirm the theoretical models. Neutron doses and dose equivalents were measured in a RANDO phantom at specific locations using thermoluminescence dosemeters, etched track dosemeters, and a 1.27 cm (1/2 in) tissue-equivalent proportional counter. The phantom was exposed to a bare and a D 2 O-moderated 252 Cf neutron source at the Pacific Northwest Laboratory's Low Scatter Facility. The Monte Carlo code MCNP with the MIRD-V mathematical phantom was used to model the human body and to calculate the organ doses and dose equivalents. The experimental methods are described and the results of the measurements are compared with the calculations. (author)

  18. The Effect of NPP's Stack Height to Radiation Dose

    International Nuclear Information System (INIS)

    Pandi, Liliana Yetta; Rohman, Budi

    2003-01-01

    The purpose of dose calculation for accidents is to analyze the capability of NPP to maintain the safety of public and workers in case an accident occurs on the Plant in a site. This paper calculates the Loss of Coolant Accident in PWR plant. The calculation results shows that no risks of serious radiation exposure are given to the neighboring public even if such a large accident occurred, and the effect of stack height can be predicted by analysis of the calculation results. The whole dose is calculated for some location (100 m, 300 m, 500 m, 700 m, 900 m, 1500 m, and 2000 m) with three difference stack height i.e. 0 m, 40 m and 100 m. The result of the whole dose calculation is under permitted criteria for whole dose : 0.25 Sv and thyroid dose : 3.0 Sv. The calculation of radiation dose in this paper use EEDCDQ code

  19. Method of simulating dose reduction for digital radiographic systems

    International Nuclear Information System (INIS)

    Baath, M.; Haakansson, M.; Tingberg, A.; Maansson, L. G.

    2005-01-01

    The optimisation of image quality vs. radiation dose is an important task in medical imaging. To obtain maximum validity of the optimisation, it must be based on clinical images. Images at different dose levels can then either be obtained by collecting patient images at the different dose levels sought to investigate - including additional exposures and permission from an ethical committee - or by manipulating images to simulate different dose levels. The aim of the present work was to develop a method of simulating dose reduction for digital radiographic systems. The method uses information about the detective quantum efficiency and noise power spectrum at the original and simulated dose levels to create an image containing filtered noise. When added to the original image this results in an image with noise which, in terms of frequency content, agrees with the noise present in an image collected at the simulated dose level. To increase the validity, the method takes local dose variations in the original image into account. The method was tested on a computed radiography system and was shown to produce images with noise behaviour similar to that of images actually collected at the simulated dose levels. The method can, therefore, be used to modify an image collected at one dose level so that it simulates an image of the same object collected at any lower dose level. (authors)

  20. Use of normalized total dose to represent the biological effect of fractionated radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Flickinger, J C; Kalend, A [Pittsburgh University School of Medicine (USA). Department of Radiation Oncology Pittsburg Cancer Institute (USA)

    1990-03-01

    There are currently a number of radiobiological models to account for the effects of dose fractionation and time. Normalized total dose (NTD) is not another new model but is a previously reported, clinically useful form in which to represent the biological effect, determined by any specific radiobiological dose-fractionation model, of a course of radiation using a single set of standardized, easily understood terminology. The generalized form of NTD reviewed in this paper describes the effect of a course of radiotherapy administered with nonstandard fractionation as the total dose of radiation in Gy that could be administered with a given reference fractionation such as 2 Gy per fraction, 5 fractions per week that would produce an equivalent biological effect (probability of complications or tumor control) as predicted by a given dose-fractionation formula. The use of normalized total dose with several different exponential and linear-quadratic dose-fraction formulas is presented. (author). 51 refs.; 1 fig.; 1 tab.

  1. Use of normalized total dose to represent the biological effect of fractionated radiotherapy

    International Nuclear Information System (INIS)

    Flickinger, J.C.; Kalend, A.

    1990-01-01

    There are currently a number of radiobiological models to account for the effects of dose fractionation and time. Normalized total dose (NTD) is not another new model but is a previously reported, clinically useful form in which to represent the biological effect, determined by any specific radiobiological dose-fractionation model, of a course of radiation using a single set of standardized, easily understood terminology. The generalized form of NTD reviewed in this paper describes the effect of a course of radiotherapy administered with nonstandard fractionation as the total dose of radiation in Gy that could be administered with a given reference fractionation such as 2 Gy per fraction, 5 fractions per week that would produce an equivalent biological effect (probability of complications or tumor control) as predicted by a given dose-fractionation formula. The use of normalized total dose with several different exponential and linear-quadratic dose-fraction formulas is presented. (author). 51 refs.; 1 fig.; 1 tab

  2. Dose-response effects in an outbreak of Salmonella enteritidis.

    OpenAIRE

    Mintz, E. D.; Cartter, M. L.; Hadler, J. L.; Wassell, J. T.; Zingeser, J. A.; Tauxe, R. V.

    1994-01-01

    The effects of ingested Salmonella enteritidis (SE) dose on incubation period and on the severity and duration of illness were estimated in a cohort of 169 persons who developed gastroenteritis after eating hollandaise sauce made from grade-A shell eggs. The cohort was divided into three groups based on self-reported dose of sauce ingested. As dose increased, median incubation period decreased (37 h in the low exposure group v. 21 h in the medium exposure group v. 17.5 h in the high exposure ...

  3. Evaluation of effective dose and excess lifetime cancer risk from ...

    African Journals Online (AJOL)

    Evaluation of effective dose and excess lifetime cancer risk from indoor and outdoor gamma dose rate of university of Port Harcourt Teaching Hospital, Rivers State. ... Therefore, the management of University of Port Harcourt teaching hospital ...

  4. Radiation dose in CT are meeting the challenge

    International Nuclear Information System (INIS)

    Wang Jun

    2003-01-01

    Despite comprising only 2% of all examinations, CT contributed around 20% of the collective dose to the population from diagnostic imaging. An abdominal examination in an adult with an effective dose of 10 mSv has been estimated to increase the lifetime risk of fatal cancer by 1 in 2000. Children are 10 times more sensitive to the effects of radiation than middle aged adults. Girls are more sensitive than boys. Variations in CT practice, ease of using, urgency in multislice CT, unawaring of the 'uncoupling effect' in CT may be contributing to increasing in radiation dose. We must train and have an awareness of emerging materials and the implied changes in practice, with revision of protocols to take account of advances. The 'as low as reasonably achievable (ALARA) ' principle applies just as much to CT as it does to conventional radiography

  5. Equivalent dose, effective dose and risk assessment from panoramic radiography to the critical organs of head and neck region

    International Nuclear Information System (INIS)

    Cho, Bong Hae; Nah, Kyung Soo; Lee, Ae Ryeon

    1995-01-01

    The purpose of this study was to evaluate the equivalent and effective dose, and estimate radiation risk to the critical organs of head and neck region from the use of adult and child mode in panoramic radiography. The results were as follows. 1. The salivary glands showed the highest equivalent and effective dose in adult and child mode. The equivalent and effective dose in adult mode were 837 μSv and 20.93 μSv, those in child mode were 462 μSv and 11.54 μSv, respectively. 2. Total effective doses to the critical head and neck organs were estimated 34.2l μSv in adult mode, 20.14 μSv in child mode. From these data, the probabilities of stochastic effect from adult and child mode were 2.50xl0 -6 and 1.47x10 -6 3. The other remainder showed the greatest risk of fatal cancer. The risk estimate were 4.5 and 2.7 fatal malignancies in adult and child mode from million examinations. The bone marrow and thyroid gland showed about 0.1 fatal cancer in adult. and child mode from these examinations.

  6. Acute cognitive effects of high doses of dextromethorphan relative to triazolam in humans

    Science.gov (United States)

    Carter, Lawrence P.; Reissig, Chad J.; Johnson, Matthew W.; Klinedinst, Margaret A.; Griffiths, Roland R.

    2012-01-01

    BACKGROUND Although concerns surrounding high-dose dextromethorphan (DXM) abuse have recently increased, few studies have examined the acute cognitive effects of high doses of DXM. The aim of this study was to compare the cognitive effects of DXM with those of triazolam and placebo. METHODS Single, acute, oral doses of DXM (100, 200, 300, 400, 500, 600, 700, 800 mg/70 kg), triazolam (0.25, 0.5 mg /70 kg), and placebo were administered p.o. to twelve healthy volunteers with histories of hallucinogen use, under double-blind conditions, using an ascending dose run-up design. Effects on cognitive performance were examined at baseline and after drug administration for up to 6 hours. RESULTS Both triazolam and DXM produced acute impairments in attention, working memory, episodic memory, and metacognition. Impairments observed following doses of 100-300 mg/70 kg DXM were generally smaller in magnitude than those observed after 0.5 mg/70 kg triazolam. Doses of DXM that impaired performance to the same extent as triazolam were in excess of 10-30 times the therapeutic dose of DXM. CONCLUSION The magnitude of the doses required for these effects and the absence of effects on some tasks within the 100-300 mg/70 kg dose range of DXM, speak to the relatively broad therapeutic window of over-the-counter DXM preparations when used appropriately. However, the administration of supratherapeutic doses of DXM resulted in acute cognitive impairments on all tasks that were examined. These findings are likely relevant to cases of high-dose DXM abuse. PMID:22989498

  7. RADIATION HYGIENIC MONITORING AND ASSESSMENT OF POPULATION DOSES IN RADIOACTIVELY CONTAMINATED AREAS OF TULA REGION

    Directory of Open Access Journals (Sweden)

    T. M. Chichura

    2016-01-01

    Full Text Available The goal. The analyses of radiation hygienic monitoring conducted in Tula region territories affected by the Chernobyl NPP accident regarding cesium-137 and strontium- 90 in the local foodstuffs and the analyses of populational annual effective dose. The materials and methods. The survey was conducted in Tula Region since 1997 to 2015. Over that period, more than fifty thousand samples of the main foodstuffs from the post-Chernobyl contaminated area were analyzed. Simultaneously with that, the external gamma - radiation dose rate was measured in the fixed control points. The dynamics of cesium -137 and strontium-90 content in foodstuffs were assessed along with the maximum values of the mean annual effective doses to the population and the contribution of the collective dose from medical exposures into the structure of the annual effective collective dose to the population. The results. The amount of cesium-137 and strontium -90 in the local foodstuffs was identified. The external gamma- radiation dose rate values were found to be stable and not exceeding the natural fluctuations range typical for the middle latitudes of Russia’s European territory. The maximum mean annual effective dose to the population reflects the stable radiation situation and does not exceed the permissible value of 1 mSv. The contribution of the collective dose from medical exposures of the population has been continuously reducing as well as the average individual dose to the population per one medical treatment under the annual increase of the medical treatments quantities. The conclusion. There is no exceedance of the admissible levels of cesium-137 and strontium- 90 content in the local foodstuffs. The mean annual effective dose to the population has decreased which makes it possible to transfer the settlements affected by the Chernobyl NPP accident to normal life style. This is covered by the draft concept of the settlements’ transfer to normal life style.

  8. Task related doses in Spanish pressurized water reactors over the period 1988-1992

    Energy Technology Data Exchange (ETDEWEB)

    O`Donnell, P.; Labarta, T.; Amor, I. [Subdireccion de Proteccion Radiologica, Madrid (Spain)

    1995-03-01

    In order to evaluate in depth the collective dose trend and its correlation with the effectiveness of the practical application of the ALARA principle in Spanish nuclear facilities, and base the different policy lines to promote this criteria, the CSN has fullfilled an analysis of the task related doses data over the period 1988-1992. Previously, the CSN had required to the utilities the compilation of their refuelling outage collective dose from 1988 according with a predeterminate number of tasks, in order to have available a representative and retrospective set of data in an homogeneous way and coherent with the international data banks on occupational exposure in NPP, as the CEC and the NEA ones. The scope of this analysis was the following: first, the collective dose summaries for outage tasks and departments for PWR and for BWR, including the minimum, maximum and average dose (and statistics data) for 18 different refuelling outage tasks and 12 personal departments for each generation of each type of rector, the task and department related collective dose trends in each plant and in each generation, and second, the dose reduction techniques having been used during that period in each plant and the relative level of adoption. In this presentation the main results and conclusions of the first part of the study are reviewed for PWR.

  9. Effective dose to staff from interventional procedures: Estimations from single and double dosimetry

    International Nuclear Information System (INIS)

    Kuipers, G.; Velders, X. L.

    2009-01-01

    The exposure of 11 physicians performing interventional procedures was measured by means of two personal dosemeters. One personal dosemeter was worn outside the lead apron and an additional under the lead apron. The study was set up in order to determine the added value of a dosemeter worn under the lead apron. With the doses measured, the effective doses of the physicians were estimated using an algorithm for single dosimetry and two algorithms for double dosimetry. The effective doses calculated with the single dosimetry algorithm ranged from 0.11 to 0.85 mSv in 4 weeks. With the double dosimetry algorithms, the effective doses ranged from 0.02 mSv to 0.47 mSv. The statistical analysis revealed no significant differences in the accuracy of the effective doses calculated with single or double dosimetry algorithms. It was concluded that the effective dose cannot be considered a more accurate estimate when two dosemeters are used instead of one. (authors)

  10. Minimizing dose variation from the interplay effect in stereotactic radiation therapy using volumetric modulated arc therapy for lung cancer.

    Science.gov (United States)

    Kubo, Kazuki; Monzen, Hajime; Tamura, Mikoto; Hirata, Makoto; Ishii, Kentaro; Okada, Wataru; Nakahara, Ryuta; Kishimoto, Shun; Kawamorita, Ryu; Nishimura, Yasumasa

    2018-03-01

    It is important to improve the magnitude of dose variation that is caused by the interplay effect. The aim of this study was to investigate the impact of the number of breaths (NBs) to the dose variation for VMAT-SBRT to lung cancer. Data on respiratory motion and multileaf collimator (MLC) sequence were collected from the cases of 30 patients who underwent radiotherapy with VMAT-SBRT for lung cancer. The NBs in the total irradiation time with VMAT and the maximum craniocaudal amplitude of the target were calculated. The MLC sequence complexity was evaluated using the modulation complexity score for VMAT (MCSv). Static and dynamic measurements were performed using a cylindrical respiratory motion phantom and a micro ionization chamber. The 1 standard deviation which were obtained from 10 dynamic measurements for each patient were defined as dose variation caused by the interplay effect. The dose distributions were also verified with radiochromic film to detect undesired hot and cold dose spot. Dose measurements were also performed with different NBs in the same plan for 16 patients in 30 patients. The correlations between dose variations and parameters assessed for each treatment plan including NBs, MCSv, the MCSv/amplitude quotient (TMMCSv), and the MCSv/amplitude quotient × NBs product (IVS) were evaluated. Dose variation was decreased with increasing NBs, and NBs of >40 times maintained the dose variation within 3% in 15 cases. The correlation between dose variation and IVS which were considered NBs was shown stronger (R 2  = 0.43, P 40 times during irradiation of two partial arcs VMAT (i.e., NBs = 16 breaths per minute) may be suitable for VMAT-SBRT for lung cancer. © 2018 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine.

  11. Review on patients radiation dose and frequency of procedures during medical exposure in Sudan

    International Nuclear Information System (INIS)

    Abu Baker, Samah Mohamed Nasr

    2015-09-01

    The aim of this study was to estimate patient dose, the annual frequency and the number of staff and devices in the medical applications of ionizing radiation in Sudan. Survey was conducted on diagnostic radiology, nuclear medicine and radiotherapy. With respect to diagnostic radiology, only patient radiation dose was estimated. The data for diagnostic radiology was obtained from 24 peer reviewed scientific published literatures during the years ( 2006 - 2015). The collected publications included about 64 Sudanese hospitals covering different types of diagnostic exams. A values of the effective dose for pediatrics and adult patients were within the ranges of similar worldwide values published by UNSCEAR report in 2008 with exceptional to fluoroscopy hysterosalpingography for adult patients. For nuclear medicine procedures, questionnaires were distributed to five hospitals representing the whole existing NM department in Sudan at the time of of study. The estimated total annual frequency of diagnostic procedures was 0.2 per 1000 population. The estimated total annual collective and annual per caput effective dose from all NM procedures were 16.268 man Sv and 0.5 μSv, respectively. Comparing the annual per caput effective dose with UNSCEAR value our results was less than the worldwide value and greater than the value for heath care level 111-1 v countries. Questionnaires were also distributed to collect data on radiotherapy procedures performed in the two existing radioisotopes Sudanese hospitals. The prescribed dose and the number of fractions were comparable between the two hospitals. The minimum prescribed dose was 20 Gy with 5 fractions for nasopharynx (NPH) palliative and the maximum prescribed dose was 64 Gy with 32 fractions for prostate.(Author)

  12. Dose rate effects during damage accumulation in silicon

    Energy Technology Data Exchange (ETDEWEB)

    Caturla, M.J.; Diaz de la Rubia, T.

    1997-01-01

    We combine molecular dynamics and Monte Carlo simulations to study damage accumulation and dose rate effects during irradiation of Silicon. We obtain the initial stage of the damage produced by heavy and light ions using classical molecular dynamics simulations. While heavy ions like As or Pt induce amorphization by single ion impact, light ions like B only produce point defects or small clusters of defects. The amorphous pockets generated by heavy ions are stable below room temperature and recrystallize at temperatures below the threshold for recrystallization of a planar amorphous-crystalline interface. The damage accumulation during light ion irradiation is simulated using a Monte Carlo model for defect diffusion. In this approach, we study the damage in the lattice as a function of dose and dose rate. A strong reduction in the total number of defects left in the lattice is observed for lower dose rates.

  13. Dose rate effects during damage accumulation in silicon

    International Nuclear Information System (INIS)

    Caturla, M.J.; Diaz de la Rubia, T.

    1997-01-01

    The authors combine molecular dynamics and Monte Carlo simulations to study damage accumulation and dose rate effects during irradiation of silicon. They obtain the initial stage of the damage produced by heavy and light ions using classical molecular dynamics simulations. While heavy ions like As or Pt induce amorphization by single ion impact, light ions like B only produce point defects or small clusters of defects. The amorphous pockets generated by heavy ions are stable below room temperature and recrystallize at temperatures below the threshold for recrystallization of a planar amorphous-crystalline interface. The damage accumulation during light ion irradiation is simulated using a Monte Carlo model for defect diffusion. In this approach, the authors study the damage in the lattice as a function of dose and dose rate. A strong reduction in the total number of defects left in the lattice is observed for lower dose rates

  14. Natural radiation level and doses to population in Anhui province

    International Nuclear Information System (INIS)

    1985-01-01

    The absorbed dose rates in air 1 m above the ground from natural radiation and terrestrial gamma radiation in Anhui Province were surveyed. One measurement was made in every area of 90 km 2 . The absorbed dose rates in air from terrestrial radiation range from 54 to 90 nGy.h -1 with an average of 70 nGy.h -1 . The ratios of indoors-to-outdoors and of roads-to-outdoors are 1.5 and 0.9 respectively. The annual effective dose equivalent from external radiation is 0.68-1.05 mSv. The population-weighted average values for mountain area, plain, hilly land, and the Changjiang River basin as well as the annual collective effective dose equivalent were calculated

  15. Classification of radiation effects for dose limitation purposes: history, current situation and future prospects

    Science.gov (United States)

    Hamada, Nobuyuki; Fujimichi, Yuki

    2014-01-01

    Radiation exposure causes cancer and non-cancer health effects, each of which differs greatly in the shape of the dose–response curve, latency, persistency, recurrence, curability, fatality and impact on quality of life. In recent decades, for dose limitation purposes, the International Commission on Radiological Protection has divided such diverse effects into tissue reactions (formerly termed non-stochastic and deterministic effects) and stochastic effects. On the one hand, effective dose limits aim to reduce the risks of stochastic effects (cancer/heritable effects) and are based on the detriment-adjusted nominal risk coefficients, assuming a linear-non-threshold dose response and a dose and dose rate effectiveness factor of 2. On the other hand, equivalent dose limits aim to avoid tissue reactions (vision-impairing cataracts and cosmetically unacceptable non-cancer skin changes) and are based on a threshold dose. However, the boundary between these two categories is becoming vague. Thus, we review the changes in radiation effect classification, dose limitation concepts, and the definition of detriment and threshold. Then, the current situation is overviewed focusing on (i) stochastic effects with a threshold, (ii) tissue reactions without a threshold, (iii) target organs/tissues for circulatory disease, (iv) dose levels for limitation of cancer risks vs prevention of non-life-threatening tissue reactions vs prevention of life-threatening tissue reactions, (v) mortality or incidence of thyroid cancer, and (vi) the detriment for tissue reactions. For future discussion, one approach is suggested that classifies radiation effects according to whether effects are life threatening, and radiobiological research needs are also briefly discussed. PMID:24794798

  16. Comparison of wrist and head TLD doses with whole body TLD doses during high active jobs at RAPS-5 and 6

    International Nuclear Information System (INIS)

    Sharma, Ravi Kant; Abhishek, Neel; Kakkar, Amandeep; Kumar, Rajesh

    2016-01-01

    In nuclear power plant radiation dose monitoring and assessment is done to control the individual dose and station collective doses. While performing a radioactive job on systems or equipment with significant radiation levels of non uniform and beaming radiation; there is potential of localized exposure to extremities hands in particular and lens of the eye in comparison to other body parts. Keeping in view of this, separate equivalent dose limit to the extremities (hands and feet) and lens of the eye are defined by ICRP. A study has been carried out during Biennial Shutdown (BSD) of RAPS-6 in the month of October-2015 to establish the correlation between the doses received by chest TLDs which is being used to estimate the effective whole body dose of the radiation worker and the doses received in wrist TLD and head TLDs which are being used to monitor the equivalent dose received by hands and lens of the eye with applying a suitable correction factor

  17. Effect of low doses gamma irradiation of cotton seeds

    International Nuclear Information System (INIS)

    Al-Oudat, M.; Khalifa, Kh.

    1996-01-01

    Field experiments and then large scale application of irradiated cotton seeds (C.V. Aleppo-40) were carried out during three seasons (1986, 1987 and 1988) for field experiment at ACSAD Station in Dier-Ezzor and 1988, 1989 and 1990 for large scale application at Euphrate's Basin, Al-Ghab and Salamia, farmers farms. The above areas were selected as they represent major cotton production areas in Syria. The aims of the experiments were to study the effect of low doses of gamma irradiation 0, 5, 10, 20, 30, 40 and 50 Gy on cotton yield and to look for the optimum dose of gamma irradiation to obtain best results. The results show that, there were positive effect (P<0.95) for doses 5-30 Gy in increasing cotton yield. The highest increase was at dose of 10 Gy. which as 19.5% higher than control. For the large scale application using 10 Gy the increase in cotton yield varied from 10-39% compared to control. (author). 11 refs., 6 figs

  18. Pulsed total dose damage effect experimental study on EPROM

    International Nuclear Information System (INIS)

    Luo Yinhong; Yao Zhibin; Zhang Fengqi; Guo Hongxia; Zhang Keying; Wang Yuanming; He Baoping

    2011-01-01

    Nowadays, memory radiation effect study mainly focus on functionality measurement. Measurable parameters is few in china. According to the present situation, threshold voltage testing method was presented on floating gate EPROM memory. Experimental study of pulsed total dose effect on EPROM threshold voltage was carried out. Damage mechanism was analysed The experiment results showed that memory cell threshold voltage negative shift was caused by pulsed total dose, memory cell threshold voltage shift is basically coincident under steady bias supply and no bias supply. (authors)

  19. Effects of small radiation doses

    International Nuclear Information System (INIS)

    Fuchs, G.

    1986-01-01

    The term 'small radiation dosis' means doses of about (1 rem), fractions of one rem as well as doses of a few rem. Doses like these are encountered in various practical fields, e.g. in X-ray diagnosis, in the environment and in radiation protection rules. The knowledge about small doses is derived from the same two forces, on which the radiobiology of human beings nearly is based: interpretation of the Hiroshima and Nagasaki data, as well as the experience from radiotherapy. Careful interpretation of Hiroshima dates do not provide any evidence that small doses can induce cancer, fetal malformations or genetic damage. Yet in radiotherapy of various diseases, e.g. inflammations, doses of about 1 Gy (100 rad) do no harm to the patients. According to a widespread hypothesis even very small doses may induce some types of radiation damage ('no threshold'). Nevertheless an alternative view is justified. At present no decision can be made between these two alternatives, but the usefullness of radiology is definitely better established than any damage calculated by theories or extrapolations. Based on experience any exaggerated fear of radiations can be met. (author)

  20. The dose effect of irradiated rice pollen on double fertilization

    International Nuclear Information System (INIS)

    Wang Houcong; Chen Zhengming; Chen Ruming; Qiu Simi; Yang Juemin; Yang Huijie

    1995-01-01

    The mature panicles of rice were treated with 60 Co γ-rays in the range of 0∼0.372 kGy. The male sterile line used as the female plants were fertilized with γ-irradiated pollen manually. The dose effect of the irradiated pollen on double fertilization was investigated. It was found that double fertilization of the irradiated pollen was suppressed to different degrees as compared with the control. The effect was noticeable as that the fusion time of the male nucleolus with the female one was delayed with the increasing of γ-radiation dose. The delayed time was less than 13 hours when the dose was below 0.186 kGy and it was more than 15 hours when the dose was above 0.279 kGy. Furthermore, several types of deformed embryonic cells and endosperm nuclei were observed

  1. Biological effective doses in the intracavitary high dose rate brachytherapy of cervical cancer

    Directory of Open Access Journals (Sweden)

    Y. Sobita Devi

    2011-12-01

    Full Text Available Purpose: The aim of this study is to evaluate the decrease of biological equivalent dose and its correlation withlocal/loco-regional control of tumour in the treatment of cervical cancer when the strength of the Ir-192 high dose rate(HDR brachytherapy (BT source is reduced to single, double and triple half life in relation to original strength of10 Ci (~ 4.081 cGy x m2 x h–1. Material and methods: A retrospective study was carried out on 52 cervical cancer patients with stage II and IIItreated with fractionated HDR-BT following external beam radiation therapy (EBRT. International Commission onRadiation Units and Measurement (ICRU points were defined according to ICRU Report 38, using two orthogonal radiographimages taken by Simulator (Simulix HQ. Biologically effective dose (BED was calculated at point A for diffe -rent Ir-192 source strength and its possible correlation with local/loco-regional tumour control was discussed. Result: The increase of treatment time per fraction of dose due to the fall of dose rate especially in HDR-BT of cervicalcancer results in reduction in BED of 2.59%, 7.02% and 13.68% with single, double and triple half life reduction ofsource strength, respectively. The probabilities of disease recurrence (local/loco-regional within 26 months are expectedas 0.12, 0.12, 0.16, 0.39 and 0.80 for source strength of 4.081, 2.041, 1.020, 0.510 and 0.347 cGy x m2 x h–1, respectively.The percentages of dose increase required to maintain the same BED with respect to initial BED were estimated as1.71, 5.00, 11.00 and 15.86 for the dose rate of 24.7, 12.4, 6.2 and 4.2 Gy/hr at point A, respectively. Conclusions: This retrospective study of cervical cancer patients treated with HDR-BT at different Ir-192 sourcestrength shows reduction in disease free survival according to the increase in treatment time duration per fraction.The probable result could be associated with the decrease of biological equivalent dose to point A. Clinical

  2. Regional radiation dose susceptibility within the parotid gland: Effects on salivary loss and recovery

    Energy Technology Data Exchange (ETDEWEB)

    Clark, Haley, E-mail: hdclark@phas.ubc.ca; Reinsberg, Stefan [Department of Physics and Astronomy, University of British Columbia, Vancouver, British Columbia V6T 1Z1 (Canada); Hovan, Allan [Oral Oncology/Dentistry, British Columbia Cancer Agency–Vancouver Centre, Vancouver, British Columbia V5Z 4E6 (Canada); Moiseenko, Vitali [Department of Radiation Medicine and Applied Sciences, University of California–San Diego, La Jolla, California 92093 (United States); Thomas, Steven [Department of Medical Physics, British Columbia Cancer Agency–Vancouver Centre, Vancouver, British Columbia V5Z 4E6 (Canada); Wu, Jonn [Radiation Oncology, British Columbia Cancer Agency–Vancouver Centre, Vancouver, British Columbia V5Z 4E6 (Canada)

    2015-04-15

    Purpose: Xerostomia is one of the most likely late toxic effects of radiotherapy treatment in patients with head-and-neck cancers. Modern treatment techniques can incorporate knowledge of complication risk into treatment plans. To this end, the authors attempt to quantify the regional radiotherapy dose-dependence of salivary output loss and recovery in a prospective study. Methods: Salivary output was collected from patients undergoing radiotherapy treatment for head-and-neck cancers at the BC Cancer Agency between February 2008 and May 2013. Regional dose-dependence (i.e., dose susceptibility) of loss and recovery is quantified using nonparametric (Spearman’s rank correlation coefficients, local linear regression) and parametric (least-sum of squares, least-median of squares) techniques. Results: Salivary flow recovery was seen in 79 of 102 patients considered (p < 0.0001, Wilcoxon sign rank test). Output loss was strongly correlated with left- and right parotid combined dose φ = min (D{sub L},  45 Gy) + min (D{sub R},  45 Gy), and can be accurately predicted. Median early loss (three months) was 72% of baseline, while median overall loss (1 yr) was 56% of baseline. Fitting an exponential model to whole parotid yields dose sensitivities A{sub 3m} = 0.0604 Gy{sup −1} and A{sub 1y} = 0.0379 Gy{sup −1}. Recovery was not significantly associated with dose. Hints of lateral organ sub-segment dose–response dimorphism were observed. Conclusions: Sub-segmentation appears to predict neither loss nor recovery with any greater precision than whole parotid mean dose, though it is not any worse. Sparing the parotid to a combined dose φ of <50 Gy is recommended for a patient to keep ≈40% of baseline function and thus avoid severe xerostomia at 12 months post-treatment. It seems unlikely that a population’s mean recovery will exceed 20%–30% of baseline output at 1 yr after radiotherapy treatment using current (whole-organ based) clinical guidelines.

  3. Annual effective dose of {sup 210}Po from sea food origin (Oysters and Mussels) in Korea

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Bo Eum; Hong, Gi Hoon; Kim, Suk Hyun; Lee, Hyun Mi [Korea Institute of Ocean Science and Technology, Ansan (Korea, Republic of)

    2016-09-15

    Ingestion of {sup 210}Po laden seafood accounts for a substantial amount of the effective dose of {sup 210}Po. Among seafood items, mollusks, especially domestically produced oysters and mussels, are highly enriched in {sup 210}Po and are consumed in large quantities in Korea. Oysters and mussels around the Korean coasts were collected from major farm areas in November 2013. Samples were spiked with an aliquot of {sup 210}Po as a yield tracer, and they were digested with 6 mol·L{sup -1} HNO{sub 3} and H{sub 2}O{sub 2}. The {sup 210}Po and {sup 209}Po were spontaneously deposited onto a silver disc in an acidic solution of 0.5 mol·L{sup -1} HCl and measured using an alpha spectrometer. The activity concentrations of {sup 210}Pb and {sup 210}Po were decay corrected to the sampling date, accounting for the possible in-growth and decay of {sup 210}Po. {sup 210}Po activity concentrations in oysters were in a range from 41.3 to 206 Bq·(kg-ww{sup -1} and mussels in a range from 42.9 to 46.7 Bq·(kg-ww){sup -1}. The {sup 210}Po activity concentration of oysters in the turbid Western coast was higher than the Southern coast. The {sup 210}Po activity concentration of the oysters was positively correlated (R2=0.89) with those of the suspended particulate matter in the surface water. The calculated annual effective dose of {sup 210}Po from oysters and mussels consumed by the Korean population was 21-104 and 5.01-5.46 μSv·y{sup -1}. The combined effective dose due to the consumption of oysters and mussels appears to account for about 35±19% of that arising from seafood consumption in the Korean population. The annual effective dose of {sup 210}Po for oysters in the Korean population was found to be higher than other countries. The total annual effective dose of 210Po{sup 210}Po due to consumption of oysters and mussels consumed in Korea was found to be 76±42 μSv·y{sup -1}, accounting for 28±16% of the total effective dose of {sup 210}Po from food in Korea.

  4. Characteristics of natural background external radiation and effective dose equivalent

    International Nuclear Information System (INIS)

    Fujimoto, Kenzo

    1989-01-01

    The two sources of natural radiation - cosmic rays and primordial radionuclides - are described. The factors affecting radiation doses received from natural radiation and the calculation of effective dose equivalent due to natural radiation are discussed. 10 figs., 3 tabs

  5. Radiation dose from cigarette tobacco

    International Nuclear Information System (INIS)

    Papastefanou, Constantin

    2008-01-01

    The radioactivity in tobacco leaves collected from 15 different regions of Greece before cigarette production was studied in order to estimate the effective dose from cigarette tobacco due to the naturally occurring primordial radionuclides, such as 226 Ra and 210 Pb of the uranium series and 228 Ra of the thorium series and or man-made produced radionuclides, such as 137 Cs of Chernobyl origin. Gamma-ray spectrometry was applied using Ge planar and coaxial type detectors of high resolution and high efficiency. It was concluded that the annual effective dose due to inhalation for adults (smokers) for 226 Ra varied from 42.5 to 178.6 μSv y -1 (average 79.7 μSv y -1 ), while for 228 Ra from 19.3 to 116.0 μSv y -1 (average 67.1 μSv y -1 ) and for 210 Pb from 47.0 to 134.9 μSv y -1 (average 104.7 μSv y -1 ), that is the same order of magnitude for each radionuclide. The sum of the effective dose of the three natural radionuclides varied from 151.9 to 401.3 μSv y -1 (average 251.5 μSv y -1 ). The annual effective dose from 137 Cs of Chernobyl origin was three orders of magnitude lower as it varied from 70.4 to 410.4 μSv y -1 (average 199.3 μSv y -1 ). (author)

  6. Mobilization and collection of CD34+ cells for autologous transplantation of peripheral blood hematopoietic progenitor cells in children: analysis of two different granulocyte-colony stimulating factor doses

    Directory of Open Access Journals (Sweden)

    Kátia Aparecida de Brito Eid

    2015-06-01

    Full Text Available Introduction: The use of peripheral hematopoietic progenitor cells (HPCs is the cell choice in autologous transplantation. The classic dose of granulocyte-colony stimulating factor (G- CSF for mobilization is a single daily dose of 10 µg/kg of patient body weight. There is a theory that higher doses of granulocyte-colony stimulating factor applied twice daily could increase the number of CD34+ cells collected in fewer leukapheresis procedures. Objective: The aim of this study was to compare a fractionated dose of 15 µg G-CSF/kg of body weight and the conventional dose of granulocyte-colony stimulating factor in respect to the number of leukapheresis procedures required to achieve a minimum collection of 3 × 106 CD34+ cells/kg body weight. Methods: Patients were divided into two groups: Group 10 - patients who received a single daily dose of 10 µg G-CSF/kg body weight and Group 15 - patients who received a fractioned dose of 15 µg G-CSF/kg body weight daily. The leukapheresis procedure was carried out in an automated cell separator. The autologous transplantation was carried out when a minimum number of 3 × 106 CD34+ cells/kg body weight was achieved. Results: Group 10 comprised 39 patients and Group 15 comprised 26 patients. A total of 146 apheresis procedures were performed: 110 (75.3% for Group 10 and 36 (24.7% for Group 15. For Group 10, a median of three (range: 1-7 leukapheresis procedures and a mean of 8.89 × 106 CD34+ cells/kg body weight (±9.59 were collected whereas for Group 15 the corresponding values were one (range: 1-3 and 5.29 × 106 cells/kg body weight (±4.95. A statistically significant difference was found in relation to the number of apheresis procedures (p-value <0.0001. Conclusions: To collect a minimum target of 3 × 106 CD34+ cells/kg body weight, the administration of a fractionated dose of 15 µg G-CSF/kg body weight significantly decreased the number of leukapheresis procedures performed.

  7. Biological radiation dose estimation by chromosomal aberrations analysis in human peripheral blood (dose-effect curve)

    International Nuclear Information System (INIS)

    Al-Achkar, W.

    2001-09-01

    In order to draw a dose-effect curve, experimentally gamma ray induced chromosomal aberrations in human peripheral lymphocytes from eight healthy people were studied. Samples from 4 males and 4 females were irradiated in tubes with 0.15, 0.25, 0.5, 1, 1.5, 2, 2.5 gray of gamma ray (Co 60 at dose rate 0.3 Gy/min). Irradiated and control samples were incubated in 37 centigrade for 48 hours cell cultures. Cell cultures then were stopped and metaphases spread, Giemsa stained to score the induced chromosomal aberrations. Chromosomal aberrations from 67888 metaphases were scored. Curves from the total number of dicentrics, dicentrics + rings and total numbers of breaks in cell for each individual or for all people were drawn. An increase of all chromosomal aberrations types with the elevation of the doses was observed. The yield of chromosome aberrations is related to the dose used. These curves give a quick useful estimation of the accidentally radiation exposure. (author)

  8. Effective dose evaluation for BNCT treatment in the epithermal neutron beam at THOR

    Energy Technology Data Exchange (ETDEWEB)

    Wang, J.N. [Department of Engineering and System Science, National Tsing Hua University, No. 101, Section 2, Kuang-Fu Rd., Hsinchu 30013, Taiwan (China)] [Division of Health Physics, Institute of Nuclear Energy Research, No. 1000, Wenhua Rd., Jiaan Village, Longtan Township, Taoyuan County 32546, Taiwan (China); Huang, C.K. [Institute of Nuclear Engineering and Science, National Tsing Hua University, No. 101, Section 2, Kuang-Fu Rd., Hsinchu 30013, Taiwan (China); Tsai, W.C. [Department of Engineering and System Science, National Tsing Hua University, No. 101, Section 2, Kuang-Fu Rd., Hsinchu 30013, Taiwan (China); Liu, Y.H. [Nuclear Science and Technol. Develop. Center, National Tsing Hua University, No. 101, Section 2, Kuang-Fu Rd., Hsinchu 30013, Taiwan (China); Jiang, S.H., E-mail: shjiang@mx.nthu.edu.tw [Department of Engineering and System Science, National Tsing Hua University, No. 101, Section 2, Kuang-Fu Rd., Hsinchu 30013, Taiwan (China)] [Institute of Nuclear Engineering and Science, National Tsing Hua University, No. 101, Section 2, Kuang-Fu Rd., Hsinchu 30013, Taiwan (China)

    2011-12-15

    This paper aims to evaluate the effective dose as well as equivalent doses of several organs of an adult hermaphrodite mathematical phantom according to the definition of ICRP Publication 60 for BNCT treatments of brain tumors in the epithermal neutron beam at THOR. The MCNP5 Monte Carlo code was used for the calculation of the average absorbed dose of each organ. The effective doses for a typical brain tumor treatment with a tumor treatment dose of 20 Gy-eq were evaluated to be 0.59 and 0.35 Sv for the LLAT and TOP irradiation geometries, respectively. In addition to the stochastic effect, it was found that it is also likely to produce deterministic effects, such as cataracts and depression of haematopoiesis.

  9. SU-E-T-802: Verification of Implanted Cardiac Pacemaker Doses in Intensity-Modulated Radiation Therapy: Dose Prediction Accuracy and Reduction Effect of a Lead Sheet

    Energy Technology Data Exchange (ETDEWEB)

    Lee, J [Dept. of Radiation Oncology, Konkuk University Medical Center, Seoul (Korea, Republic of); Chung, J [Dept. of Radiation Oncology, Seoul National University Bundang Hospital, Seongnam (Korea, Republic of)

    2015-06-15

    Purpose: To verify delivered doses on the implanted cardiac pacemaker, predicted doses with and without dose reduction method were verified using the MOSFET detectors in terms of beam delivery and dose calculation techniques in intensity-modulated radiation therapy (IMRT). Methods: The pacemaker doses for a patient with a tongue cancer were predicted according to the beam delivery methods [step-and-shoot (SS) and sliding window (SW)], intensity levels for dose optimization, and dose calculation algorithms. Dosimetric effects on the pacemaker were calculated three dose engines: pencil-beam convolution (PBC), analytical anisotropic algorithm (AAA), and Acuros-XB. A lead shield of 2 mm thickness was designed for minimizing irradiated doses to the pacemaker. Dose variations affected by the heterogeneous material properties of the pacemaker and effectiveness of the lead shield were predicted by the Acuros-XB. Dose prediction accuracy and the feasibility of the dose reduction strategy were verified based on the measured skin doses right above the pacemaker using mosfet detectors during the radiation treatment. Results: The Acuros-XB showed underestimated skin doses and overestimated doses by the lead-shield effect, even though the lower dose disagreement was observed. It led to improved dose prediction with higher intensity level of dose optimization in IMRT. The dedicated tertiary lead sheet effectively achieved reduction of pacemaker dose up to 60%. Conclusion: The current SS technique could deliver lower scattered doses than recommendation criteria, however, use of the lead sheet contributed to reduce scattered doses.Thin lead plate can be a useful tertiary shielder and it could not acuse malfunction or electrical damage of the implanted pacemaker in IMRT. It is required to estimate more accurate scattered doses of the patient with medical device to design proper dose reduction strategy.

  10. SU-E-T-802: Verification of Implanted Cardiac Pacemaker Doses in Intensity-Modulated Radiation Therapy: Dose Prediction Accuracy and Reduction Effect of a Lead Sheet

    International Nuclear Information System (INIS)

    Lee, J; Chung, J

    2015-01-01

    Purpose: To verify delivered doses on the implanted cardiac pacemaker, predicted doses with and without dose reduction method were verified using the MOSFET detectors in terms of beam delivery and dose calculation techniques in intensity-modulated radiation therapy (IMRT). Methods: The pacemaker doses for a patient with a tongue cancer were predicted according to the beam delivery methods [step-and-shoot (SS) and sliding window (SW)], intensity levels for dose optimization, and dose calculation algorithms. Dosimetric effects on the pacemaker were calculated three dose engines: pencil-beam convolution (PBC), analytical anisotropic algorithm (AAA), and Acuros-XB. A lead shield of 2 mm thickness was designed for minimizing irradiated doses to the pacemaker. Dose variations affected by the heterogeneous material properties of the pacemaker and effectiveness of the lead shield were predicted by the Acuros-XB. Dose prediction accuracy and the feasibility of the dose reduction strategy were verified based on the measured skin doses right above the pacemaker using mosfet detectors during the radiation treatment. Results: The Acuros-XB showed underestimated skin doses and overestimated doses by the lead-shield effect, even though the lower dose disagreement was observed. It led to improved dose prediction with higher intensity level of dose optimization in IMRT. The dedicated tertiary lead sheet effectively achieved reduction of pacemaker dose up to 60%. Conclusion: The current SS technique could deliver lower scattered doses than recommendation criteria, however, use of the lead sheet contributed to reduce scattered doses.Thin lead plate can be a useful tertiary shielder and it could not acuse malfunction or electrical damage of the implanted pacemaker in IMRT. It is required to estimate more accurate scattered doses of the patient with medical device to design proper dose reduction strategy

  11. Effect of dose rate on intestinal tolerance in mice. Implications in radiotherapy

    International Nuclear Information System (INIS)

    Wambersie, A.; Stienon-Smoes, M.R.; Octave-Prignot, M.

    1978-01-01

    Effect of dose rate on intestinal tolerance after 60 Co irradiation was studied in BALB/c mice. Intestinal tolerance was assessed from LD50, after selective abdominal irradiation and after total body irradiation. Three dose rates were compared, corresponding to irradiation times of about 15-20 minutes ('acute irradiation' taken as reference), 5-6 hours and 10-15 hours. Irradiations were performed simultaneously, with three telecobaltherapy units, the dose rates being adjusted with lead shields and by increasing the distances. Comparison of the experimental data already published indicates that, for some biological systems and effects, additional dose necessary to reach a given effect when passing from 'acute' to 'continuous low dose rate' irradiation is comparable to that expected when considering only repair of sublethal lesions. For other biological systems and effects, it is necessary to consider, besides repair of sublethal lesions, other mechanisms such as cell distribution and, for tumours, the oxygen effect. A differential effect then appears to be possible. However, as far as the clinical applications are concerned, a general agreement is not yet reached on the exact shape of the iso-effect curves as a function of irradiation time for the effects relevant to radiation therapy [fr

  12. Assessment of radioactivity and estimation of effective dose received by villagers residing at natural high background areas of coastal regions of Tamil Nadu

    International Nuclear Information System (INIS)

    Esaiselvan, K.; Rajagopal, R.; Sreekumar, K.; Harikumar, M.; AllenGnanaraj, G.

    2010-01-01

    Radiation exposure and effective dose received by villagers residing at seven villages belonging to Natural High Background Radiation Areas (NHBRA) of coastal regions of Tamil Nadu were studied; five houses in each village were selected. The NHBRA villages were Chinnavilai, Periavilai, Kottilpadu, Puthoor Colachel, Kodimunai and Midalam. The houses were of similar construction pattern (brick wall-tiled roof, cement flooring). Measurements of radon ( 222 Rn), thoron ( 220 Rn) and their progeny, produced by the decay of naturally occurring radioisotopes uranium and thorium in dwellings are the largest contributor to the average internal effective dose received by human beings. Internal doses due to radon/thoron and their progeny were estimated using, Solid State Nuclear Track Detectors (SSNTD), LR-115, as the detector. External doses were estimated by gamma measurement using scintillometer and Thermo Luminescent Dosimeter (TLD). TLDs were exposed for one year, on a quarterly basis, inside the house at a height of 3 meters and about 1 meter away from the walls. The SSNTD cups were exposed adjacent to the TLDS, and the exposure was for a period of three months each. The SSNTDs were developed by standard procedures (10% NaOH, etching for 90 min at 60 deg C) and counted in a spark counter. Earlier the SSNTDs were calibrated using U and Th sources and calibration factors were obtained. Inhalation dose due to 232 Th and Th (B) in mWL were estimated by collecting air samples from each house, for one hour each, during the replacement time of TLD and SSNTD Cups. For inhalation dose estimation the occupancy factor was assumed to be 0.8. The soil samples were also collected from each sampling point. (author)

  13. A review of in vitro dose-effect relationships

    International Nuclear Information System (INIS)

    Dolphin, G.W.

    1978-01-01

    One of the principal reasons for investigating the relationship between absorbed dose and the number of chromosome aberrations per cell in lymphocytes taken from samples of human peripheral blood is to obtain a calibration curve for biological dosimetry. Factors affecting the radiation-induced aberration yield in vitro of T lymphocytes are reviewed under the following heads: temperature, oxygen effect, inter-mitotic death, mitotic delay, dose rate background of aberrations in normal humans, mathematical representation. (U.K.)

  14. COCAINE AND PAVLOVIAN FEAR CONDITIONING: DOSE-EFFECT ANALYSIS

    OpenAIRE

    Wood, Suzanne C.; Fay, Jonathon; Sage, Jennifer R.; Anagnostaras, Stephan G.

    2006-01-01

    Emerging evidence suggests that cocaine and other drugs of abuse can interfere with many aspects of cognitive functioning. The authors examined the effects of 0.1 – 15 mg/kg of cocaine on Pavlovian contextual and cued fear conditioning in mice. As expected, pre-training cocaine dose-dependently produced hyperactivity and disrupted freezing. Surprisingly, when the mice were tested off-drug later, the group pre-treated with a moderate dose of cocaine (15 mg/kg) displayed significantly less cont...

  15. Dose- dependent ameliorative effects of quercetin and l-Carnitine against atrazine- induced reproductive toxicity in adult male Albino rats.

    Science.gov (United States)

    Abdel Aziz, Rabie L; Abdel-Wahab, Ahmed; Abo El-Ela, Fatma I; Hassan, Nour El-Houda Y; El-Nahass, El-Shaymaa; Ibrahim, Marwa A; Khalil, Abdel-Tawab A Y

    2018-06-01

    This study aimed to determine the protective effects of co-administration of Quercetin (QT) or l-Carnitine (LC) against the oxidative stress induced by Atrazine (ATZ) in the reproductive system of intact male Albino rats. 36 rats were divided equally into 6 groups. Rats in the control negative "CNT" group received 1.5 ml distilled water for 21 days. All rats in the other groups received ATZ (120 mg/kg bw) through gavage. Groups 3 and 4 were co-administered with either low or high dose of QT (10 "ATZLQT" and 50 "ATZHQT" mg/kg bw, respectively). Groups 5 and 6 were co-administered with either low or high dose of LC (200 "ATZLLC" and 400 "ATZHLC" mg/kg bw, respectively). At the end of the experiment, animals were sacrificed and all samples were collected. ATZ significantly increased serum level of malondialdehyde (MDA) and decreased total antioxidant capacity (TAC). Also, ATZ increased significantly the sperm cell abnormalities and reduced both testicular IgA and serum testosterone levels. Testicular DNA laddering % and CYP17A1 mRNA expression were significantly reduced in ATZ group. Interestingly, co-administration with low dose QT or different doses of LC succeeded to counteract the negative toxic effects of ATZ on serum oxidative stress indicators, serum testosterone levels, testicular IgA level and improved testicular CYP17A1 mRNA expression. In conclusion, QT in low dose and LC in both low and high doses exerted a significant protective action against the reproductive toxicity of ATZ, while higher dose of QT failed induce immune-stimulant effect against ATZ in adult male Albino rats. Copyright © 2018 Elsevier Masson SAS. All rights reserved.

  16. Effects of high doses of enalapril and benazepril on the pharmacologically activated renin-angiotensin-aldosterone system in clinically normal dogs.

    Science.gov (United States)

    Ames, Marisa K; Atkins, Clarke E; Lee, Seunggon; Lantis, Andrea C; zumBrunnen, James R

    2015-12-01

    To determine whether high doses of enalapril and benazepril would be more effective than standard doses of these drugs in suppressing the furosemide-activated renin-angiotensin-aldosterone system (RAAS). 6 healthy Beagles. 2 experiments were conducted; each lasted 10 days, separated by a 2-week washout period. In experiment 1, all dogs received furosemide (2 mg/kg, PO, q 12 h) and enalapril (1 mg/kg, PO, q 12 h) for 8 days (days 0 through 7). In experiment 2, dogs received furosemide (2 mg/kg, PO, q 12 h) and benazepril (1 mg/kg, PO, q 12 h) for 8 days. Effects on the RAAS were determined by assessing serum angiotensin-converting enzyme (ACE) activity on days -1, 3, and 7; serum aldosterone concentration on days -2, -1, 1, 3, and 7; and the urinary aldosterone-creatinine ratio (UAldo:C) in urine collected in the morning and evening of days -2, -1, 1, 3, and 7. High doses of enalapril and benazepril caused significant reductions in serum ACE activity on all days but were not more effective than standard doses used in other studies. Mean UAldo:C remained significantly higher on days 2 through 7, compared with baseline values. Serum aldosterone concentration also increased after drug administration, which mirrored changes in the UAldo:C. In this study, administration of high doses of enalapril and benazepril significantly inhibited ACE activity, yet did not prevent increases in mean urine and serum aldosterone concentrations resulting from furosemide activation of RAAS. This suggested that aldosterone breakthrough from ACE inhibition was a dose-independent effect of ACE inhibitors.

  17. Melanin is Effective Radioprotector against Chronic Irradiation and Low Radiation Doses

    International Nuclear Information System (INIS)

    Mosse, I.; Plotnikova, S.; Kostrova, L.; Molophei, V.; Dubovic, B.

    2001-01-01

    Full text: Earlier we found pigment melanin ability to reduce significantly genetic consequences of acute irradiation in animals (drosophila, mice) and cultured human cells and to decrease strongly 'genetic load' accumulated in irradiated populations. The influence of melanin isolated from human hair on genetic effects of chronic irradiation in mice has been investigated. Melanin suspension or distilled water were injected every day into stomach of animals during 1-3 Gy g-irradiation with dose rate 0.007Gy/h. Levels of reciprocal translocations in germ cells were analysed cytologically. Melanin influence on genetic effect of chronic irradiation was shown to be even more effective than that of acute one. Radioadaptive response was used in order to study melanin influence on low radiation dose effect. We have demonstrated adaptive response in mice germ cells and bone marrow cells frequency of chromosomal aberrations in these cells after 0.2+1.5 Gy was about half as much as 1.7 Gy effect. Melanin injection 2 hours before the conditioning dose of 0.2 Gy resulted in the same mutation level as before 1.7 Gy adaptive response was not found. If melanin was applied between the first and second doses, both adaptive reaction and protection led to 4-fold decrease in aberration level. Thus melanin is able to remove completely low radiation dose effect. Complete toxicological tests have been conducted. The pigment melanin is not toxic and does not possess a mutagenic, teratogenic or carcinogenic activity. Melanin could be used in medicine for people protection against genetic consequences of long-term irradiation at low doses. (author)

  18. Estimation of organ and effective dose due to Compton backscatter security scans

    International Nuclear Information System (INIS)

    Hoppe, Michael E.; Schmidt, Taly Gilat

    2012-01-01

    Purpose: To estimate organ and effective radiation doses due to backscatter security scanners using Monte Carlo simulations and a voxelized phantom set. Methods: Voxelized phantoms of male and female adults and children were used with the GEANT4 toolkit to simulate a backscatter security scan. The backscatter system was modeled based on specifications available in the literature. The simulations modeled a 50 kVp spectrum with 1.0 mm-aluminum-equivalent filtration and a previously measured exposure of approximately 4.6 μR at 30 cm from the source. Photons and secondary interactions were tracked from the source until they reached zero kinetic energy or exited from the simulation’s boundaries. The energy deposited in the phantoms’ respective organs was tallied and used to calculate total organ dose and total effective dose for frontal, rear, and full scans with subjects located 30 and 75 cm from the source. Results: For a full screen, all phantoms’ total effective doses were below the established 0.25 μSv standard, with an estimated maximum total effective dose of 0.07 μSv for full screen of a male child. The estimated maximum organ dose due to a full screen was 1.03 μGy, deposited in the adipose tissue of the male child phantom when located 30 cm from the source. All organ dose estimates had a coefficient of variation of less than 3% for a frontal scan and less than 11% for a rear scan. Conclusions: Backscatter security scanners deposit dose in organs beyond the skin. The effective dose is below recommended standards set by the Health Physics Society (HPS) and the American National Standards Institute (ANSI) assuming the system provides a maximum exposure of approximately 4.6 μR at 30 cm.

  19. A comparison of anti-tumor effects of high dose rate fractionated and low dose rate continuous irradiation in multicellular spheroids

    International Nuclear Information System (INIS)

    Kubota, Nobuo; Omura, Motoko; Matsubara, Sho.

    1997-01-01

    In a clinical experience, high dose rate (HDR) fractionated interstitial radiotherapy can be an alternative to traditional low dose rate (LDR) continuous interstitial radiotherapy for head and neck cancers. To investigate biological effect of HDR, compared to LDR, comparisons have been made using spheroids of human squamous carcinoma cells. Both LDR and HDR were delivered by 137 Cs at 37degC. Dose rate of LDR was 8 Gy/day and HDR irradiations of fraction size of 4, 5 or 6 Gy were applied twice a day with an interval time of more than 6 hr. We estimated HDR fractionated dose of 31 Gy with 4 Gy/fr to give the same biological effects of 38 Gy by continuous LDR for spheroids. The ratio of HDR/LDR doses to control 50% spheroids was 0.82. (author)

  20. The effect of low changes in radiation dose on the hatching data of rainbow trout

    International Nuclear Information System (INIS)

    Buehringer, H.; Kellermann, H.J.

    1993-01-01

    Radiation hormesis hypothesis refers to the occurrence of a biphasic dose-respond relationship in which higher doses cause an inhibitory effect and lower doses cause a stimulatory effect. By extrapolation of this thesis there could be suggested a radiation damage effect below normal background radiation doses. Rainbow trout eggs, which are very radiation sensitive, were fertilized and incubated in environments with abient radiation (Hamburg), increased doses of radiation and decreased level of radiation doses (ASSE II). Hatching data (incubation time, hatching time, hatching success, number and kind of malformations, length of larvae) were examined for a hormesis effect. Only in hatching success a statistically significant effect of radiation dose was noticeable. (orig.) [de

  1. Genotoxic effects of high dose rate X-ray and low dose rate gamma radiation in ApcMin/+ mice.

    Science.gov (United States)

    Graupner, Anne; Eide, Dag M; Brede, Dag A; Ellender, Michele; Lindbo Hansen, Elisabeth; Oughton, Deborah H; Bouffler, Simon D; Brunborg, Gunnar; Olsen, Ann Karin

    2017-10-01

    Risk estimates for radiation-induced cancer in humans are based on epidemiological data largely drawn from the Japanese atomic bomb survivor studies, which received an acute high dose rate (HDR) ionising radiation. Limited knowledge exists about the effects of chronic low dose rate (LDR) exposure, particularly with respect to the application of the dose and dose rate effectiveness factor. As part of a study to investigate the development of colon cancer following chronic LDR vs. acute HDR radiation, this study presents the results of genotoxic effects in blood of exposed mice. CBAB6 F1 Apc +/+ (wild type) and Apc Min/+ mice were chronically exposed to estimated whole body absorbed doses of 1.7 or 3.2 Gy 60 Co-γ-rays at a LDR (2.2 mGy h -1 ) or acutely exposed to 2.6 Gy HDR X-rays (1.3 Gy min -1 ). Genotoxic endpoints assessed in blood included chromosomal damage (flow cytometry based micronuclei (MN) assay), mutation analyses (Pig-a gene mutation assay), and levels of DNA lesions (Comet assay, single-strand breaks (ssb), alkali labile sites (als), oxidized DNA bases). Ionising radiation (ca. 3 Gy) induced genotoxic effects dependent on the dose rate. Chromosomal aberrations (MN assay) increased 3- and 10-fold after chronic LDR and acute HDR, respectively. Phenotypic mutation frequencies as well as DNA lesions (ssb/als) were modulated after acute HDR but not after chronic LDR. The Apc Min/+ genotype did not influence the outcome in any of the investigated endpoints. The results herein will add to the scant data available on genotoxic effects following chronic LDR of ionising radiation. Environ. Mol. Mutagen. 58:560-569, 2017. © 2017 The Authors Environmental and Molecular Mutagenesis published by Wiley Periodicals, Inc. on behalf of Environmental Mutagen Society. © 2017 The Authors Environmental and Molecular Mutagenesis published by Wiley Periodicals, Inc. on behalf of Environmental Mutagen Society.

  2. Dose-Effect Relationships for Individual Pelvic Floor Muscles and Anorectal Complaints After Prostate Radiotherapy

    International Nuclear Information System (INIS)

    Smeenk, Robert Jan; Hoffmann, Aswin L.; Hopman, Wim P.M.; Lin, Emile N.J. Th. van; Kaanders, Johannes H.A.M.

    2012-01-01

    Purpose: To delineate the individual pelvic floor muscles considered to be involved in anorectal toxicity and to investigate dose-effect relationships for fecal incontinence-related complaints after prostate radiotherapy (RT). Methods and Materials: In 48 patients treated for localized prostate cancer, the internal anal sphincter (IAS) muscle, the external anal sphincter (EAS) muscle, the puborectalis muscle (PRM), and the levator ani muscles (LAM) in addition to the anal wall (Awall) and rectal wall (Rwall) were retrospectively delineated on planning computed tomography scans. Dose parameters were obtained and compared between patients with and without fecal urgency, incontinence, and frequency. Dose-effect curves were constructed. Finally, the effect of an endorectal balloon, which was applied in 28 patients, was investigated. Results: The total volume of the pelvic floor muscles together was about three times that of the Awall. The PRM was exposed to the highest RT dose, whereas the EAS received the lowest dose. Several anal and rectal dose parameters, as well as doses to all separate pelvic floor muscles, were associated with urgency, while incontinence was associated mainly with doses to the EAS and PRM. Based on the dose-effect curves, the following constraints regarding mean doses could be deduced to reduce the risk of urgency: ≤30 Gy to the IAS; ≤10 Gy to the EAS; ≤50 Gy to the PRM; and ≤40 Gy to the LAM. No dose-effect relationships for frequency were observed. Patients treated with an endorectal balloon reported significantly less urgency and incontinence, while their treatment plans showed significantly lower doses to the Awall, Rwall, and all pelvic floor muscles. Conclusions: Incontinence-related complaints show specific dose-effect relationships to individual pelvic floor muscles. Dose constraints for each muscle can be identified for RT planning. When only the Awall is delineated, substantial components of the continence apparatus are

  3. Dose-effect relationships for individual pelvic floor muscles and anorectal complaints after prostate radiotherapy.

    Science.gov (United States)

    Smeenk, Robert Jan; Hoffmann, Aswin L; Hopman, Wim P M; van Lin, Emile N J Th; Kaanders, Johannes H A M

    2012-06-01

    To delineate the individual pelvic floor muscles considered to be involved in anorectal toxicity and to investigate dose-effect relationships for fecal incontinence-related complaints after prostate radiotherapy (RT). In 48 patients treated for localized prostate cancer, the internal anal sphincter (IAS) muscle, the external anal sphincter (EAS) muscle, the puborectalis muscle (PRM), and the levator ani muscles (LAM) in addition to the anal wall (Awall) and rectal wall (Rwall) were retrospectively delineated on planning computed tomography scans. Dose parameters were obtained and compared between patients with and without fecal urgency, incontinence, and frequency. Dose-effect curves were constructed. Finally, the effect of an endorectal balloon, which was applied in 28 patients, was investigated. The total volume of the pelvic floor muscles together was about three times that of the Awall. The PRM was exposed to the highest RT dose, whereas the EAS received the lowest dose. Several anal and rectal dose parameters, as well as doses to all separate pelvic floor muscles, were associated with urgency, while incontinence was associated mainly with doses to the EAS and PRM. Based on the dose-effect curves, the following constraints regarding mean doses could be deduced to reduce the risk of urgency: ≤ 30 Gy to the IAS; ≤ 10 Gy to the EAS; ≤ 50 Gy to the PRM; and ≤ 40 Gy to the LAM. No dose-effect relationships for frequency were observed. Patients treated with an endorectal balloon reported significantly less urgency and incontinence, while their treatment plans showed significantly lower doses to the Awall, Rwall, and all pelvic floor muscles. Incontinence-related complaints show specific dose-effect relationships to individual pelvic floor muscles. Dose constraints for each muscle can be identified for RT planning. When only the Awall is delineated, substantial components of the continence apparatus are excluded. Copyright © 2012 Elsevier Inc. All rights

  4. Analysis of T101 outage radiation dose

    International Nuclear Information System (INIS)

    Li, Zhonghua

    2008-01-01

    Full text: Collective radiation dose during outage is about 80% of annual collective radiation dose at nuclear power plants (NPPs). T 101 Outage is the first four-year outage of Unit 1 at Tianwan Nuclear Power Station (TNPS) and thorough overhaul was undergone for the 105-day's duration. Therefore, T 101 Outage has significant reference meaning to reducing collective radiation dose at TNPS. This paper collects the radiation dose statistics during T 101 Outage and analyses the radiation dose distribution according to tasks, work kinds and varying trend of the collective radiation dose etc., comparing with other similar PWRs in the world. Based on the analysis this paper attempts to find out the major factors in collective radiation dose during T 101 Outage. The major positive factor is low radiation level at workplace, which profits from low content of Co in reactor construction materials, optimised high-temperature p H value of the primary circuit coolant within the tight range and reactor operation without trips within the first fuel cycle. One of the most negative factors is long outage duration and many person-hours spent in the radiological controlled zone, caused by too many tasks and inefficient work. So besides keeping good performance of reducing radioactive sources, it should be focused on how to improve implementation of work management including work selection, planning and scheduling, work preparation, work implementation, work assessment and feedback, which can lead to reduced numbers of workers needed to perform a task, of person-hours spent in the radiological controlled zone. Moreover, this leads to reduce occupational exposures in an ALARA fashion. (author)

  5. Effects of low doses of alcohol on declarative memory in humans

    Directory of Open Access Journals (Sweden)

    José Arturo Bríñez-Horta

    2011-09-01

    Full Text Available This study assessed the effect of low doses of alcohol on two elements of explicit or declarative memory, in 16 participants, 8 women and 8 men, with The Weschler Memory Scale III Text Test. A factorial 2 * 4 counterbalanced with repeated measures design was used. There were no statistically significant differences by gender, but there were differences among doses, specially 0.150 g / Kg., which reduced episodic and semantic retrieval, between 43.9 and 62.9 % of effect strength, in intermediate term memory. These results provided evidence that alcohol in low doses has a more pronounced effect in semantic, rather than episodic memory, in the middle term

  6. Dose monitoring in radiology departments. Status quo and future perspectives

    International Nuclear Information System (INIS)

    Boos, J.; Bethge, O.T.; Antoch, G.; Kroepil, P.

    2016-01-01

    The number of computed tomography examinations has continuously increased over the last decades and accounts for a major part of the collective radiation dose from medical investigations. For purposes of quality assurance in modern radiology a systematic monitoring and analysis of dose related data from radiological examinations is mandatory. Various ways of collecting dose data are available today, for example the Digital Imaging and Communication in Medicine - Structured Report (DICOM-SR), optical character recognition and DICOM-modality performed procedure steps (MPPS). The DICOM-SR is part of the DICOM-standard and provides the DICOM-Radiation Dose Structured Report, which is an easily applicable and comprehensive solution to collect radiation dose parameters. This standard simplifies the process of data collection and enables comprehensive dose monitoring. Various commercial dose monitoring software devices with varying characteristics are available today. In this article, we discuss legal obligations, various ways to monitor dose data, current dose monitoring software solutions and future perspectives in regard to the EU Council Directive 2013/59/EURATOM.

  7. Level of radon and its daughters, and internal exposure doses in Shaanxi province

    International Nuclear Information System (INIS)

    Fan Xin; Zhang Yawei; Yu Huilian

    1992-01-01

    About 4500 indoor and outdoor air samples were collected with FDT-84 sampler throughout Shaanxi Province in various seasons, and the concentrations of radon and its daughters in the air were determined with FD-3016 scintillator. Meanwhile, the diurnal, seasonal and altitudinal variation of radon and its progeny in Xi'an area were observed. The annual effective dose equivalent for individual adult resident was estimated to be 1.73 mSv·a -1 and the annual collective effective dose equivalent for the residents- in the whole province was estimated to be 5.09 ± 10 4 man.Sv·a -1 . The concentration levels and the doses are within the range of the data published in UNSCEAR reports in recent years, and all of them are in the normal range of the natural background

  8. MEASUREMENT OF RADON EXHALATION RATE, RADIUM ACTIVITY AND ANNUAL EFFECTIVE DOSE FROM BRICKS AND CEMENT SAMPLES COLLECTED FROM DERA ISMAIL KHAN

    OpenAIRE

    Nisar Ahmad; Mohamad Suhaimi Jaafar; Sohail Aziz Khan; Tabassum Nasir; Sajjad Ahmad; Muhammad Rahim

    2014-01-01

    Radon concentration, exhalation rate, radium activity and annual effective dose have been measured from baked and unbaked bricks and cement samples commonly used as construction material in the dwellings of Dera Ismail Khan City, Pakistan. CR-39 based NRPB radon dosimeters and RAD7 have been used as passive and active devises. The values of radon concentration for baked, unbaked bricks and cements obtained from passive and active techniques were found in good agreement. Average values of rado...

  9. Savannah River Site dose control

    International Nuclear Information System (INIS)

    Smith, L.S.

    1992-01-01

    Health physicists from the Brookhaven National Laboratory (BNL) visited the Savannah River Site (SRS) as one of 12 facilities operated by the Department of Energy (DOE) contractors with annual collective dose equivalents greater than 100 person-rem (100 person-cSv). Their charter was to review, evaluate and summarize as low as reasonably achievable (ALARA) techniques, methods and practices as implemented. This presentation gives an overview of the two selected ALARA practices implemented at the SRS: Administrative Exposure Limits and Goal Setting. These dose control methods are used to assure that individual and collective occupational doses are ALARA and within regulatory limits

  10. Estimation of outdoor and indoor effective dose and excess lifetime cancer risk from Gamma dose rates in Gonabad, Iran

    Energy Technology Data Exchange (ETDEWEB)

    Jafaria, R.; Zarghania, H.; Mohammadia, A., E-mail: rvzreza@gmail.com [Paramedical faculty, Birjand University of Medical Sciences, Birjand (Iran, Islamic Republic of)

    2017-07-01

    Background gamma irradiation in the indoor and outdoor environments is a major concern in the world. The study area was Gonabad city. Three stations and buildings for background radiation measurement of outdoor and indoor were randomly selected and the Geiger-Muller detector (X5C plus) was used. All dose rates on display of survey meter were recorded and mean of all data in each station and buildings was computed and taken as measured dose rate of that particular station. The average dose rates of background radiation were 84.2 nSv/h for outdoor and 108.6 nSv/h for indoor, maximum and minimum dose rates were 88.9 nSv/h and 77.7 nSv/h for outdoor measurements and 125.4 nSv/h and 94.1 nSv/h for indoor measurements, respectively. Results show that the annual effective dose is 0.64 mSv, which compare to global level of the annual effective dose 0.48 mSv is high. Estimated excess lifetime cancer risk was 2.24×10{sup -3} , indicated that it is large compared to the world average value of 0.25×10{sup -3}. (author)

  11. Experimental study on x-rays dose enhancement effects for floating gate ROMs

    CERN Document Server

    Guo Hong Xia; Chen Yu Sheng; Han Fu Bin; He Chao Hui; Zhao Hui

    2002-01-01

    Experimental results of x-ray dose enhancement effects are given for floating gate read-only memory (ROMs) irradiated in the Beijing Synchrotron Radiation Facility. The wrong byte numbers vs. total irradiation dose have been tested and the equivalent relation of total dose damage is provided compared the response of devices irradiated with sup 6 sup 0 Co gamma-ray source. The x-ray dose enhancement factors for floating gate ROMs are obtained firstly in China. These results can be an effective evaluation data for x-rays radiation hardening technology

  12. Effects of Chronic Low-Dose Radiation on Human Neural Progenitor Cells

    Science.gov (United States)

    Katsura, Mari; Cyou-Nakamine, Hiromasa; Zen, Qin; Zen, Yang; Nansai, Hiroko; Amagasa, Shota; Kanki, Yasuharu; Inoue, Tsuyoshi; Kaneki, Kiyomi; Taguchi, Akashi; Kobayashi, Mika; Kaji, Toshiyuki; Kodama, Tatsuhiko; Miyagawa, Kiyoshi; Wada, Youichiro; Akimitsu, Nobuyoshi; Sone, Hideko

    2016-01-01

    The effects of chronic low-dose radiation on human health have not been well established. Recent studies have revealed that neural progenitor cells are present not only in the fetal brain but also in the adult brain. Since immature cells are generally more radiosensitive, here we investigated the effects of chronic low-dose radiation on cultured human neural progenitor cells (hNPCs) derived from embryonic stem cells. Radiation at low doses of 31, 124 and 496 mGy per 72 h was administered to hNPCs. The effects were estimated by gene expression profiling with microarray analysis as well as morphological analysis. Gene expression was dose-dependently changed by radiation. By thirty-one mGy of radiation, inflammatory pathways involving interferon signaling and cell junctions were altered. DNA repair and cell adhesion molecules were affected by 124 mGy of radiation while DNA synthesis, apoptosis, metabolism, and neural differentiation were all affected by 496 mGy of radiation. These in vitro results suggest that 496 mGy radiation affects the development of neuronal progenitor cells while altered gene expression was observed at a radiation dose lower than 100 mGy. This study would contribute to the elucidation of the clinical and subclinical phenotypes of impaired neuronal development induced by chronic low-dose radiation.

  13. Monte Carlo dose calibration in CT scanner

    International Nuclear Information System (INIS)

    Yadav, Poonam; Ramasubramanian, V.; Subbaiah, K.V.; Thayalan, K.

    2008-01-01

    Computed Tomography (CT) scanner is a high radiation imaging modality compared to radiography. The dose from a CT examination can vary greatly depending on the particular CT scanner used, the area of the body examined, and the operating parameters of the scan. CT is a major contributor to collective effective dose in diagnostic radiology. Apart from the clinical benefits, the widespread use of multislice scanner is increasing radiation level to patient in comparison with conventional CT scanner. So, it becomes necessary to increase awareness about the CT scanner. (author)

  14. Environmental exposure to low-doses of ionizing radiation. Effects on early nephrotoxicity in mice.

    Science.gov (United States)

    Bellés, Montserrat; Gonzalo, Sergio; Serra, Noemí; Esplugas, Roser; Arenas, Meritxell; Domingo, José Luis; Linares, Victoria

    2017-07-01

    Nuclear accidents of tremendous magnitude, such as those of Chernobyl (1986) and Fukushima (2011), mean that individuals living in the contaminated areas are potentially exposed to ionizing radiation (IR). However, the dose-response relationship for effects of low doses of radiation is not still established. The present study was aimed at investigating in mice the early effects of low-dose internal radiation exposure on the kidney. Adult male (C57BL/6J) mice were divided into three groups. Two groups received a single subcutaneous (s.c.) doses of cesium ( 137 Cs) with activities of 4000 and 8000Bq/kg bw. A third group (control group) received a single s.c. injection of 0.9% saline. To evaluate acute and subacute effects, mice (one-half of each group) were euthanized at 72h and 10 days post-exposure to 137 Cs, respectively. Urine samples were collected for biochemical analysis, including the measurement of F2-isoprostane (F2-IsoP) and kidney injury molecule-1 (KIM-1) levels. Moreover, the concentrations of 8-hydroxy-2'-deoxyguanosine (8-OHdG), a sensitive marker of oxidative DNA damage, were measured in renal tissue. Urinary excretion of total protein significantly increased at 72h in mice exposed to Cs4000. Uric acid and lactate dehydrogenase (LDH) decreased significantly at both times post-exposure in animals exposed to Cs8000. After 72h and 10d of exposure to Cs4000, a significant increase in the γ-glutamil transferase (GGT) and N-acetyl-β-D-glucosaminidase (NAG) activities was observed. In turn, F2-IsoP levels increased -mainly in the Cs4000 group- at 72h post-exposure. Following irradiation ( 137 Cs), the highest level of KIM-1 was corresponded to the Cs4000 group at 72h. Likewise, the main DNA damage was detected in mice exposed to Cs4000, mainly at 10d after irradiation. The alterations observed in several biomarkers suggest an immediate renal damage following exposure to low doses of IR (given as 137 Cs). Further investigations are required to clarify the

  15. Daily radionuclide ingestion and internal radiation doses in Aomori prefecture, Japan.

    Science.gov (United States)

    Ohtsuka, Yoshihito; Kakiuchi, Hideki; Akata, Naofumi; Takaku, Yuichi; Hisamatsu, Shun'ichi

    2013-10-01

    To assess internal annual dose in the general public in Aomori Prefecture, Japan, 80 duplicate cooked diet samples, equivalent to the food consumed over a 400-d period by one person, were collected from 100 volunteers in Aomori City and the village of Rokkasho during 2006–2010 and were analyzed for 11 radionuclides. To obtain average rates of ingestion of radionuclides, the volunteers were selected from among office, fisheries, agricultural, and livestock farm workers. Committed effective doses from ingestion of the diet over a 1-y period were calculated from the analytical results and from International Commission on Radiological Protection dose coefficients; for 40K, an internal effective dose rate from the literature was used. Fisheries workers had significantly higher combined internal annual dose than the other workers, possibly because of high rates of ingestion of marine products known to have high 210Po concentrations. The average internal dose rate, weighted by the numbers of households in each worker group in Aomori Prefecture, was estimated at 0.47 mSv y-1. Polonium-210 contributed 49% of this value. The sum of committed effective dose rates for 210Po, 210Pb, 228Ra, and 14C and the effective dose rate of 40K accounted for approximately 99% of the average internal dose rate.

  16. Verification of an effective dose equivalent model for neutrons

    International Nuclear Information System (INIS)

    Tanner, J.E.; Piper, R.K.; Leonowich, J.A.; Faust, L.G.

    1991-10-01

    Since the effective dose equivalent, based on the weighted sum of organ dose equivalents, is not a directly measurable quantity, it must be estimated with the assistance of computer modeling techniques and a knowledge of the radiation field. Although extreme accuracy is not necessary for radiation protection purposes, a few well-chosen measurements are required to confirm the theoretical models. Neutron measurements were performed in a RANDO phantom using thermoluminescent dosemeters, track etch dosemeters, and a 1/2-in. (1.27-cm) tissue equivalent proportional counter in order to estimate neutron doses and dose equivalents within the phantom at specific locations. The phantom was exposed to bare and D 2 O-moderated 252 Cf neutrons at the Pacific Northwest Laboratory's Low Scatter Facility. The Monte Carlo code MCNP with the MIRD-V mathematical phantom was used to model the human body and calculate organ doses and dose equivalents. The experimental methods are described and the results of the measurements are compared to the calculations. 8 refs., 3 figs., 3 tabs

  17. On the uncertainties in effective dose estimates of adult CT head scans

    International Nuclear Information System (INIS)

    Gregory, Kent J.; Bibbo, Giovanni; Pattison, John E.

    2008-01-01

    Estimates of the effective dose to adult patients from computed tomography (CT) head scanning can be calculated using a number of different methods. These estimates can be used for a variety of purposes, such as improving scanning protocols, comparing different CT imaging centers, and weighing the benefits of the scan against the risk of radiation-induced cancer. The question arises: What is the uncertainty in these effective dose estimates? This study calculates the uncertainty of effective dose estimates produced by three computer programs (CT-EXPO, CTDosimetry, and ImpactDose) and one method that makes use of dose-length product (DLP) values. Uncertainties were calculated in accordance with an internationally recognized uncertainty analysis guide. For each of the four methods, the smallest and largest overall uncertainties (stated at the 95% confidence interval) were: 20%-31% (CT-EXPO), 15%-28% (CTDosimetry), 20%-36% (ImpactDose), and 22%-32% (DLP), respectively. The overall uncertainties for each method vary due to differences in the uncertainties of factors used in each method. The smallest uncertainties apply when the CT dose index for the scanner has been measured using a calibrated pencil ionization chamber

  18. Position displacement effect on the doses in the peripheral head regions

    International Nuclear Information System (INIS)

    Kortesniemi, M.; Seppaelae, T.; Bjugg, H.; Seren, T.; Kotiluoto, P.; Auterinen, I.; Parkkinen, R.; Savolainen, S.

    2000-01-01

    Patient positioning is a challenging task in BNCT-treatments due to the use of multiple fields and a static horizontal beam construction. Positioning accuracy of 5 mm is required for acceptable dose delivery within appropriate limits of dose uncertainty (up to 10% of point dose in target volume). The aim of this study was to determine if a patient head position creating a clear gap between the beam port and the head would have a significant effect on the doses to the peripheral regions of the head, e.g. to the eyes. The gamma dose rates were measured in a water filled ellipsoidal phantom with an ionisation chamber (IC). Mn activation wires were used to determine the Mn-55(n, γ) reaction rates. Twelve measurement points were chosen in the phantom and two phantom positions were applied. According to this study the 35 mm position change and the resulting gap has an obvious effect on the peripheral doses in BNCT. The Mn activation reaction rates were on the average 80% higher in the deviation position than in the reference position. Increasing depth from the surface inside the phantom diminished the gamma dose difference between the two positions. Scattering environment changes with position displacement and resulting gap causes differences in neutron fluences and gamma doses. (author)

  19. Effects of low dose gamma radiation on the early growth of red pepper and the resistance to subsquent high dose of radiation

    Energy Technology Data Exchange (ETDEWEB)

    Kim, J. S.; Baek, M. H.; Kim, D. H.; Lee, Y. K. [KAERI, Taejon (Korea, Republic of); Lee, Y. B. [Chungnam National Univ., Taejon (Korea, Republic of)

    2001-05-01

    Red pepper (capsicum annuum L. cv. Jokwang and cv. Johong) seeds were irradiated with the dose of 0{approx}50 Gy to investigated the effect of the low dose gamma radiation on the early growth and resistance to subsequent high dose of radiation. The effect of the low dose gamma radiation on the early growth and resistance to subsequenct high dose of radiation were enhanced in Johong cultivar but not in Jokwang cultivar. Germination rate and early growth of Johong cultivar were noticeably increased at 4 Gy-, 8 Gy- and 20 Gy irradiation group. Resistance to subsequent high dose of radiation of Johong cultivar were increased at almost all of the low dose irradiation group. Especially it was highest at 4 Gy irradiation group. The carotenoid contents and enzyme activity on the resistance to subsequent high dose of radiation of Johong cultivar were increased at the 4 Gy and 8 Gy irradiation group.

  20. A Unified Probabilistic Framework for Dose-Response Assessment of Human Health Effects.

    Science.gov (United States)

    Chiu, Weihsueh A; Slob, Wout

    2015-12-01

    When chemical health hazards have been identified, probabilistic dose-response assessment ("hazard characterization") quantifies uncertainty and/or variability in toxicity as a function of human exposure. Existing probabilistic approaches differ for different types of endpoints or modes-of-action, lacking a unifying framework. We developed a unified framework for probabilistic dose-response assessment. We established a framework based on four principles: a) individual and population dose responses are distinct; b) dose-response relationships for all (including quantal) endpoints can be recast as relating to an underlying continuous measure of response at the individual level; c) for effects relevant to humans, "effect metrics" can be specified to define "toxicologically equivalent" sizes for this underlying individual response; and d) dose-response assessment requires making adjustments and accounting for uncertainty and variability. We then derived a step-by-step probabilistic approach for dose-response assessment of animal toxicology data similar to how nonprobabilistic reference doses are derived, illustrating the approach with example non-cancer and cancer datasets. Probabilistically derived exposure limits are based on estimating a "target human dose" (HDMI), which requires risk management-informed choices for the magnitude (M) of individual effect being protected against, the remaining incidence (I) of individuals with effects ≥ M in the population, and the percent confidence. In the example datasets, probabilistically derived 90% confidence intervals for HDMI values span a 40- to 60-fold range, where I = 1% of the population experiences ≥ M = 1%-10% effect sizes. Although some implementation challenges remain, this unified probabilistic framework can provide substantially more complete and transparent characterization of chemical hazards and support better-informed risk management decisions.