  1. ATLAS Cold Leg Top Slot Break Analysis using RELAP5

    Energy Technology Data Exchange (ETDEWEB)

    Sung, Haejung; Lee, Sang Ik; Park, Ju-Hyun; Choi, Tong-Soo [KEPCO NF, Daejeon (Korea, Republic of)

    2016-10-15

    U.S. Nuclear Regulatory Commission (US-NRC) has been reviewing the design certification application for APR1400 submitted by Korea Electric Power Corporation (KEPCO). The main concern about cold leg top slot break is that cladding temperature might be increased by core uncover due to four loop seal reformation following flooding of safety injection water. An integral effect test for cold leg top slot break was performed by KAERI (Korea Atomic Energy Research Institute) using ATLAS (Advanced Thermal-Hydraulic Test Loop for Accident Simulation), which is a scaled down experimental facility for APR1400. In this study, RELAP5/MOD3.3/Patch04 is assessed by experimental result of ATLAS cold leg top slot break. Also, thermal hydraulic phenomena by four loop seals reformation is observed by RELAP5 result. The RELAP5/MOD3.3/Patch04 is assessed by the experimental result of ATLAS cold leg top slot break. The top slot break is described by offtake model, and the mass flow rate is fairly well estimated. The RELAP5 well predicts the correlation between general trend and four loop seal reformation. The pressure of the core region and the cladding temperature tends to increase during four loop seal reformation due to steam path blockage on four loop seals. It is presumed that the code cannot estimate two phase phenomena by loop seal clearing as same as experiments. In terms of cladding temperature, loop seal reformation due to loop seal elevation of APR1400 does not need to be the issue, since the void fraction at the active top core is maintained over 0.4.

  2. Analysis of large break loss of coolant accident with simultaneous injection into cold leg and hot leg

    International Nuclear Information System (INIS)

    Luo Bangqi

    1997-01-01

    When a large break loss of coolant accident occurs, the most part of the safety injection water injected into the cold leg by the safety injection system will flow through the channel between the pressure vessel and the barrel out of the break into the containment, only a little part of the safety injection water can flow into the reactor core. If the safety injection can inject into both the cold leg and the hot leg simultaneously, the safety injection water injected from the cold leg will flow into the core more easily, because the safety injection water injected from the hot leg will carry out more heat from the upper plenum and the core, so the upper plenum and the core is depressed. In addition, a small part of the safety injection water injected from the hot leg will flow down in the core after impinging the guide tubes in the upper plenum, so the core will get more safety injection water than only cold leg injection, and the core will be much safer

  3. Comparison of the DVI line break LOCA with the equivalent cold leg break with the ATLAS facility

    International Nuclear Information System (INIS)

    Choi, K. Y.; Cho, S.; Kang, K. H.; Park, H. S.; Kim, Y. S.; Baek, W. P.

    2010-01-01

    The APR1400 (Advanced Power Reactor, 1400 MWe) adopts a DVI (Direct Vessel Injection) method for ECC (Emergency Core Cooling) water delivery rather than a conventional CLI (Cold Leg Injection) method as an advanced safety feature. The break scenario of one DVI nozzle is taken into account in the small break LOCA analysis. Transient behavior during the DVI line breaks needs to be investigated and compared with the equivalent break on the cold leg. An 8.5-inch double-ended break of one DVI nozzle was simulated with the ATLAS, and a counterpart test for the DVI break was performed at the cold leg with the equivalent break size for comparison. This comparison will contribute to enhancing a comprehensive understanding of the thermal hydraulic behavior during transients. A constructed integral effect database is also used to validate the existing conservative safety analysis methodology and to develop a best-estimate safety analysis methodology for small-break LOCAs. A post-test calculation was performed with a best-estimate safety analysis code, MARS 3.1, in order to examine its prediction capability and to identify any code deficiencies for thermal hydraulic phenomena occurring during the transient. (authors)

  4. PSB-VVER counterpart experiment simulating a small cold leg break LOCA

    International Nuclear Information System (INIS)

    Blinkov, V.N.; Melikhov, O.I.; Kapustin, A.V.; Lipatov, I.A.; Dremin, G.I.; Nikonov, S.M.; Rovnov, A.A.; Elkin, I.V.; Pylev, S.S.

    2005-01-01

    Full text of publication follows: An experiment simulating a small break LOCA has been performed in PSB-VVER facility, under PSB-VVER OECD Project. The test is intended to be a counterpart one to an experiment performed in the LOBI integral test facility. The objectives of the PSB-VVER small cold leg break test are: to study VVER-1000 thermal hydraulic response following a small break in the cold leg, to provide data for code assessment regarding phenomena indicated in the VVER-1000 code validation matrix and to study the scaling effect. The scenario for the PSB-VVER experiment has been designed taking the LOBI BL-34 test as reference. The ratio of primary system volumes (without volume of the pressurizer and the surge line) has been chosen to scale the reference experiment conditions and to generate the conditions of PSB-VVER cold leg break experiment. The resulting conditions are compared with the LOBI cold leg break test conditions by means of different counterpart test criteria. Comparing the two experiments in terms of the criteria shows that basic requirements to the counterpart test are fulfilled. A pretest analysis with RELAP5/MOD3.2 code has shown that the PSBVVER small break experiment is expected to show the same relevant phenomena and main events as the LOBI BL-34 test. The predicted PSB-VVER primary pressure is very close to that measured in the LOBI facility. The measured pressure in the PSB-VVER primary system has turned out to be very close to that registered in LOBI BL-34 test. This verifies the approach used for developing the conditions of the PSB-VVER counterpart test. The experiment results and the RELAP5/MOD3.2 pretest calculation are in good agreement. A posttest calculation of the experiment with RELAP5/MOD3.2 code has been performed in order to assess the codes capability to simulate the phenomena relevant to the test. The code has shown a reasonable prediction of the phenomena measured in the experiment. (authors)

  5. PSB-VVER counterpart experiment simulating a small cold leg break LOCA

    Energy Technology Data Exchange (ETDEWEB)

    Blinkov, V.N.; Melikhov, O.I.; Kapustin, A.V.; Lipatov, I.A.; Dremin, G.I.; Nikonov, S.M.; Rovnov, A.A. [Elektrogorsk Research and Engineering Center, EREC, Bezymiannaja Street, 6, Elektrogorsk, Moscow Region, 142530 (Russian Federation); Elkin, I.V.; Pylev, S.S. [NSI RRC ' Kurchatov Institute' , Kurchatov Sq., 1, Moscow, 123182 (Russian Federation)

    2005-07-01

    Full text of publication follows: An experiment simulating a small break LOCA has been performed in PSB-VVER facility, under PSB-VVER OECD Project. The test is intended to be a counterpart one to an experiment performed in the LOBI integral test facility. The objectives of the PSB-VVER small cold leg break test are: to study VVER-1000 thermal hydraulic response following a small break in the cold leg, to provide data for code assessment regarding phenomena indicated in the VVER-1000 code validation matrix and to study the scaling effect. The scenario for the PSB-VVER experiment has been designed taking the LOBI BL-34 test as reference. The ratio of primary system volumes (without volume of the pressurizer and the surge line) has been chosen to scale the reference experiment conditions and to generate the conditions of PSB-VVER cold leg break experiment. The resulting conditions are compared with the LOBI cold leg break test conditions by means of different counterpart test criteria. Comparing the two experiments in terms of the criteria shows that basic requirements to the counterpart test are fulfilled. A pretest analysis with RELAP5/MOD3.2 code has shown that the PSBVVER small break experiment is expected to show the same relevant phenomena and main events as the LOBI BL-34 test. The predicted PSB-VVER primary pressure is very close to that measured in the LOBI facility. The measured pressure in the PSB-VVER primary system has turned out to be very close to that registered in LOBI BL-34 test. This verifies the approach used for developing the conditions of the PSB-VVER counterpart test. The experiment results and the RELAP5/MOD3.2 pretest calculation are in good agreement. A posttest calculation of the experiment with RELAP5/MOD3.2 code has been performed in order to assess the codes capability to simulate the phenomena relevant to the test. The code has shown a reasonable prediction of the phenomena measured in the experiment. (authors)

  6. The Numerical Sensitivity Study of Cold Leg Top Slot Break for ATLAS

    Energy Technology Data Exchange (ETDEWEB)

    Sung, Hae Jung; Lee, Sang Ik; Park, Ju hyun; Choi, Tong Soo [KEPCO, Daejeon (Korea, Republic of)

    2016-05-15

    In this study, cold leg top slot break calculations are performed by RELAP5/MOD3.3 Patch04 for the ATLAS test which is the scaled down experimental facility for the APR1400. The test condition for base case is selected as 0.1016 m (4 in.) based on the break size of the APR1400. In addition, sensitivity studies about break size, break distance from vessel, and pressurizer location are performed until the initiation of simultaneous injection of 2.5 hours. The loop seal reformation occurs early, and the duration of final loop seal reformation is longer as the break is close to vessel. Nonetheless, PCT increased by loop seal reformation is not identified since core uncovery does not occur. In this study, it is confirmed through RELAP5 simulation of the ATLAS test that cold leg top slot break for the APR1400 is not a safety issue in perspective of the loop seal reformation.

  7. Cold-Leg Small Break LOCA Analysis of APR1400 Plant Using a SPACE/sEM Code

    International Nuclear Information System (INIS)

    Lim, Sang Gyu; Lee, Suk Ho; Yu, Keuk Jong; Kim, Han Gon; Lee, Jae Yong

    2013-01-01

    The Small Break Loss-of-Coolant Accident (SBLOCA) evaluation methodology (EM) for APR1400, called sEM, is now being developed using SPACE code. SPACE/sEM is to set up a conservative evaluation methodology in accordance with appendix K of 10 CFR 50. Major required and acceptable features of the evaluation models are described as below. - Fission product decay : 1.2 times of ANS97 decay curve - Critical flow model : Henry-Fauske Moody two phase critical flow model - Metal-Water reaction model : Baker-Just equation - Critical Heat Flux (CHF) : B and W, Barnett and Modified Barnett correlation - Post-CHF : Groeneveld 5.7 film boiling correlation A series of test matrix is established to validate SPACE/sEM code in terms of major SBLOCA phenomena, e.g. core level swelling and boiling, core heat transfer, critical flow, loop seal clearance and their integrated effects. The separated effect tests (SETs) and integrated effect tests (IETs) are successfully performed and these results shows that SPACE/sEM code has a conservatism comparing with experimental data. Finally, plant calculations of SBLOCA for APR1400 are conducted as described below. - Break location sensitivity : DVI line, hot-leg, cold-leg, pump suction leg. - Break size spectrum : 0.4ft 2 ∼0.02ft 2 (DVI) 0.5ft 2 ∼0.02ft 2 (hot-leg, cold-leg, pump suction leg) This paper deals with break size spectrum analysis of cold-leg break accidents. Based on the calculation results, emergency core cooling system (ECCS) performances of APR1400 and typical SBLOCA phenomena can be evaluated. Cold-leg SBLOCA analysis for APR1400 is performed using SPACE/sEM code under harsh environment condition. SPACE/sEM code shows the typical SBLOCA behaviors and it is reasonably predicted. Although SPACE/sEM code has conservative models and correlations based on appendix K of 10 CFR 50, PCT does not exceed the requirement (1477 K). It is concluded that ECCS in APR1400 has a sufficient performance in cold-leg SBLOCA

  8. Cold-Leg Small Break LOCA Analysis of APR1400 Plant Using a SPACE/sEM Code

    Energy Technology Data Exchange (ETDEWEB)

    Lim, Sang Gyu; Lee, Suk Ho; Yu, Keuk Jong; Kim, Han Gon; Lee, Jae Yong [Central Research Institute, KHNP, Ltd., Daejeon (Korea, Republic of)

    2013-10-15

    The Small Break Loss-of-Coolant Accident (SBLOCA) evaluation methodology (EM) for APR1400, called sEM, is now being developed using SPACE code. SPACE/sEM is to set up a conservative evaluation methodology in accordance with appendix K of 10 CFR 50. Major required and acceptable features of the evaluation models are described as below. - Fission product decay : 1.2 times of ANS97 decay curve - Critical flow model : Henry-Fauske Moody two phase critical flow model - Metal-Water reaction model : Baker-Just equation - Critical Heat Flux (CHF) : B and W, Barnett and Modified Barnett correlation - Post-CHF : Groeneveld 5.7 film boiling correlation A series of test matrix is established to validate SPACE/sEM code in terms of major SBLOCA phenomena, e.g. core level swelling and boiling, core heat transfer, critical flow, loop seal clearance and their integrated effects. The separated effect tests (SETs) and integrated effect tests (IETs) are successfully performed and these results shows that SPACE/sEM code has a conservatism comparing with experimental data. Finally, plant calculations of SBLOCA for APR1400 are conducted as described below. - Break location sensitivity : DVI line, hot-leg, cold-leg, pump suction leg. - Break size spectrum : 0.4ft{sup 2}∼0.02ft{sup 2}(DVI) 0.5ft{sup 2}∼0.02ft{sup 2}(hot-leg, cold-leg, pump suction leg) This paper deals with break size spectrum analysis of cold-leg break accidents. Based on the calculation results, emergency core cooling system (ECCS) performances of APR1400 and typical SBLOCA phenomena can be evaluated. Cold-leg SBLOCA analysis for APR1400 is performed using SPACE/sEM code under harsh environment condition. SPACE/sEM code shows the typical SBLOCA behaviors and it is reasonably predicted. Although SPACE/sEM code has conservative models and correlations based on appendix K of 10 CFR 50, PCT does not exceed the requirement (1477 K). It is concluded that ECCS in APR1400 has a sufficient performance in cold-leg SBLOCA.

  9. PWR cold-leg small break loca with faulty HPI

    International Nuclear Information System (INIS)

    Kumamaru, H.; Kukita, Y.

    1991-01-01

    The ROSA-IV Large Scale Test Facility (LSTF) is a 1/48 volumetrically-scaled model of a pressurized water reactor (PWR). At the LSTF are performed cold-leg small-break loss-of-coolant accident (LOCA) tests with faulty high pressure injection (HPI) system for break areas from 0.5% to 10% and an intentional primary system depressurization test following a small-break LOCA test. A simple prediction model is proposed for prediction of times of major events. Test data and calculations show that intentional primary system depressurization with use of the pressurizer power-operated relief valves (PORVs) is effective for break areas of approximately 0.5% or less, is unnecessary for breaks of 5% or more, and is insufficient for intermediate break areas to maintain adequate core cooling. (author)

  10. Temporary core liquid level depression during cold-leg small-break LOCA effect of break size and power level

    International Nuclear Information System (INIS)

    Koizumi, Y.; Kumamaru, H.; Mimura, Y.; Kukita, Y.; Tasaka, K.

    1989-01-01

    Cold-leg small break LOCA experiments (0.5-10% break) were conducted at the large scale test facility (LSTF), a volumetrically-scaled (1/48) simulator of a PWR, of the ROSA-IV Program. When a break area was less than 2.5% of the scaled cold-leg flow area, the core liquid level was temporarily further depressed to the bottom elevation of the crossover leg during the loop seal clearing early in the transient only by the manometric pressure balance since no coolant remained in the upper portion of the primary system. When the break size was larger than 5%, the core liquid level was temporarily further depressed lower than the bottom elevation of the crossover leg during the loop seal clearing since coolant remained at the upper portion of the primary system; the steam generator (SG) U-tube upflow side and the SG inlet plenum, due to counter current flow limiting by updrafting steam while the coolant drained. The amount of coolant trapped there was dependent on the vapor velocity (core power); the larger the core power, the lower the minimum core liquid level. The RELAP5/MOD2 code reasonable predicted phenomena observed in the experiments. (orig./DG)

  11. UPTF/TEST10B/RUN081, Steam/Water Flow Phenomena Reflood PWR Cold Leg Break LOCA

    International Nuclear Information System (INIS)

    1998-01-01

    1 - Description of test facility: The Upper Plenum Test Facility (UPTF) is a geometrical full-scale simulation of the primary system of the four-loop 1300 MWe Siemens/KWU pressurized water reactor (PWR) at Grafenrheinfeld. The test vessel, upper plenum and its internals, downcomer, primary loops, pressurizer and surge line are replicas of the reference plant. The core, coolant pumps, steam generators and containment of a PWR are replaced by simulators which simulate the boundary and initial conditions during end-of-blowdown, refill and reflood phase following a loss-of-coolant accident (LOCA) with a hot or cold leg break. The break size and location can be simulated in the broken loop. The emergency core coolant (ECC) injection systems at the UPTF are designed to simulate the various ECC injection modes, such as hot leg, upper plenum, cold leg, downcomer or combined hot and cold leg injection of different ECC systems of German and US/Japan PWRs. Moreover, eight vent valves are mounted in the core barrel above the hot leg nozzle elevation for simulation of ABB and B and W PWRs. The UPTF primary system is divided into the investigation and simulation areas. The investigation areas, which are the exact replicas of a GPWR, consist of the upper plenum with internals, hot legs, cold legs and downcomer. The realistic thermal-hydraulic behavior in the investigation areas is assured by appropriate initial and boundary conditions of the area interface. The boundary conditions are realized by above mentioned simulators, the setup and the operation of which are based on small-scale data and mathematical models. The simulation areas include core simulator, steam generator simulators, pump simulators and containment simulator. The steam production and entrainment in a real core during a LOCA are simulated by steam and water injection through the core simulator. 2 - Description of test: Investigation of steam/water flow phenomena at the upper tie plate and in the upper plenum and

  12. TRAC-PD2 modeling of LOFT and PWR small cold-leg breaks

    International Nuclear Information System (INIS)

    Knight, T.D.; Willcutt, G.J.E. Jr.; Lime, J.F.

    1981-01-01

    The Transient Reactor Analysis Code (TRAC) is being developed at the Los Alamos National Laboratory to provide advanced best-estimate predictions of postulated accidents in light-water reactors. TRAC-PD2, the latest publicly released version of the code, is currently being tested against small-break and other transients in experimental facilities; it is also being used to analyze postulated accidents in commercial power reactors. Calculated results for LOFT small-break experiments are compared to data, and the results from two small-break calculations for two different reactor systems are presented. It is concluded that TRAC-PD2 is useful for the analysis of cold-leg small-break accidents

  13. Analysis of the ATLAS Cold Leg Top-Slot Break Experiment Using the MARS Code

    Energy Technology Data Exchange (ETDEWEB)

    Ha, T. W.; Jeong, J. J. [Pusan National University, Busan (Korea, Republic of)

    2016-10-15

    During a small-break loss of coolant accident (SBLOCA) or intermediate-break loss of coolant accident (IBLOCA) in a PWR, such as the APR1400, the steam volume in the reactor vessel upper plenum may continue to expand until the liquid phase in the horizontal intermediate legs is released, called loop seal clearing (LSC), due to the increase of the pressure in the upper plenum. A domestic standard problem (DSP) exercise using the ATLAS facility was promoted in order to transfer the database to domestic nuclear industries. For 4th DSP (DSP-04), the ATLAS cold leg top-slot break experiment was postulated. For the DSP-04, main concerns are to predict the LSC and LSR having a significantly effect on the behavior of the system under long term cooling. In this study, we simulated the ATLAS cold leg top-slot break experiment using the MARS code and the predicted LSC and LSR are compared to experimental results. The LTC-CL-04R was simulated using the MARS code. Most of the predicted results agree well with the experimental data. However, the timing of LSC and LSR is slightly different from each other and, thus, the behavior of the primary system is slightly different. The core heat up was not observed in the experiment and the calculation.

  14. Leak-before-break due to fatigue cracks in the cold leg piping system

    International Nuclear Information System (INIS)

    Mayfield, M.E.; Collier, R.P.

    1984-01-01

    This review paper presents the results of a deterministic assessment of the margin of safety against a large break in the cold leg piping system of pressurized water reactors. The paper focuses on the computation of leak rates resulting from fatigue cracks that penetrate the full wall thickness. Results are presented that illustrate the sensitivity of the leak rate to stress level, crack shape and crack orientation. Further, the leak rates for specific conditions are contrasted to detection levels, shutdown criteria, make-up capacity and the leak rate associated with final failure of the piping system. The results of these computations indicate that, in general, leaks far in excess of the present detection sensitivities would result at crack sizes well below the critical crack sizes for the upset loadings on the cold leg piping system

  15. Assessment of the MARS-KS Code Using Atlas 6-inch cold leg Break Test

    Energy Technology Data Exchange (ETDEWEB)

    Kang, D. G.; Kim, J. S.; Ahn, S. H.; Seul, K. W. [Korea Institute of Nuclear Safety, Daejeon (Korea, Republic of)

    2012-03-15

    An integral effect test on the SBLOCA (Small-Break Loss of Coolant Accident) aiming at 6-inch cold leg bottom break, SB-CL-09, was conducted with the Atlas on November, 13, 2009, by KAERI. In this study, the calculations using MARS-KS Vt1.2 code were conducted for 6-inch cold leg break test of Atlas (SB-CL-09) which is the second domestic standard problem (Dsp-02) to assess MARS-KS code capability to simulate the transient thermal-hydraulic behavior for SBLOCA. The steady state was determined by conducting a null transient calculation and the errors between the calculated and measured values are acceptable for almost primary/secondary system parameters. The predicted pressurizer pressure agrees relatively well with the experimental data and the predicted break flow and mass are in good agreement with experiment. In MARS-KS calculation, the decrease of core collapsed water level is predicted well in blowdown phase, but just before LSC, water level is higher than experiment. However, the sudden decrease and increase of water level is higher than experiment. However, the sudden decrease and increase of water level at the LSC are predicted qualitatively. After LSC, there is another water level dip at Sit injection time which is not in experiment. It is considered that this phenomenon is caused by rapid depressurization of downcomer due to significant condensation rate of vapor in downcomer when Sit water flows in it. For the downcomer water level is predicted well, however, it is significantly over-predicted at SIT injection time, water level is predicted well, however, it is significantly over-predicted at SIT injection time after SIT water flows in downcomer. Predicted cladding temperature generally agrees well with the experiment, while there is peak at SIT injection time in calculation which is not in experiment. The loop seals of 1A, 2B intermediate leg are cleared around 400 seconds in experiment, while only that of 1A is cleared in MARS-KS calculation at the

  16. Analysis of ATLAS 6-inch cold leg break simulation with MARS-KS code

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Se Yun; Jun, Hwang Yong; Ha, Sang Jun [Korea Electric Power Company, Daejeon (Korea, Republic of)

    2011-05-15

    A Domestic Standard Problem (DSP) exercise using ATLAS facility has been organized by KAERI. As the second DSP exercise, the 6-inch cold leg bottom break was determined. This experiment is the counterpart test to the DVI line break to verify the safety performance of the DVI method over the traditional CLI method. Compared with the large break LOCA, the phases of the small break LOCA prior to core recovery occur over a long period. The blowdown, natural circulation, loop seal clearance, boil-off, and core recovery phase should be investigated minutely with relevant models of safety analysis codes in order to predict these thermal hydraulic phenomena correctly. To investigate the ECC bypass phenomena, a finer study on the thermalhydraulic behavior in upper annulus downcomer was carried out

  17. An analysis methodology for hot leg break mass and energy release

    International Nuclear Information System (INIS)

    Song, Jin Ho; Kwon, Young Min; Kim, Taek Mo; Chung, Hae Yong; Lee, Sang Jong

    1996-07-01

    An analysis methodology for the hot leg break mass and energy release is developed. For the blowdown period a modified CEFLASH-4A analysis is suggested. For the post-blowdown period a new computer model named COMET is developed. Differently from previous post-blowdown analysis model FLOOD3, COMET is capable of analyzing both cold leg and hot leg break cases. The cold leg break model is essentially same as that of FLOOD3 with some improvements. The analysis results by the newly proposed hot leg break model in the COMET is in the same trend as those observed in scaled-down integral experiment. And the analyses results for the UCN 3 and 4 by COMET are qualitatively and quantitatively in good agreement with those predicted by best-estimate analysis by using RELAP5/MOD3. Therefore, the COMET code is validated and can be used for the licensing analysis. 6 tabs., 82 figs., 9 refs. (Author)

  18. Data report for ROSA-IV LSTF 10% hot leg break experiment Run SB-HL-04

    International Nuclear Information System (INIS)

    Kukita, Yutaka; Nakamura, Hideo; Saeki, Hiroyuki

    1991-03-01

    Experimental data for the 10% hot leg break test, Run SB-HL-04, conducted on March 29, 1988 at the ROSA-IV Large Scale Test Facility (LSTF), are presented. This test was conducted as part of test series which studied the effect of break orientation on 10% hot leg break transient, and represented a vertical upward break. Other two tests in this test series represented horizontal break and vertical downward break, respectively. The results of these tests were characterized by asymmetric loop responses, flashing in the cold legs as well as upper downcomer, and condensation depressurization in the cold legs following injection of emergency core coolant (ECC) from accumulators. (author)

  19. Loss of Coolant Accident Simulation for the Top-Slot break at Cold Leg Focusing on the Loop Seal Reformation under Long Term Cooling with the ATLAS

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jong Rok; Park, Yu Sun; Bae, Byoung Uhn; Choi, Nam Hyun; Kang, Kyoung Ho; Choi, Ki Yong [KAERI, Daejeon (Korea, Republic of)

    2016-05-15

    In the present paper, loss of coolant accident for the top-slot break at cold leg was simulated with the ATLAS, which is a thermal-hydraulic integral effect test facility for evolutionary pressurized water reactors (PWRs) of an advanced power reactor of 1400 MWe (APR1400). The simulation was focused on the loop seal reformation under long term cooling condition. During a certain class of Loss of Coolant Accident (LOCA) in a PWR like an advanced power reactor of 1400 MWe (APR1400), the steam volume in the reactor vessel upper plenum and/or upper head may continue expanding until steam blows liquid out of the intermediate leg (U-shaped pump suction cold leg), called loop seal clearing (LSC), opening a path for the steam to be relieved from the break. Prediction of the LSC phenomena is difficult because they are varies for many parameters, which are break location, type, size, etc. This LSC is the major factor that affects the coolant inventory in the small break LOCA (SBLOCA) or intermediate break LOCA (IBLOCA). There is an issue about the loop seal reformation that liquid refills intermediate leg and blocks the steam path after LSC. During the SBLOCA or IBLOCA, the Emergency Core Cooling System (ECCS) is operated. For long term of the top slot small or intermediate break at cold leg, the primary steam condensation by SG heat transfer or SIP, SIT water flooding (reverse flow to loop seal) make loop seal reformation possibly. The primary pressure increase at the top core region due to the steam release blockage by loop seal reformation. And then core level decreases and partial core uncover may occur. The loss of coolant accident for the top-slot break at cold leg was simulated with the ATLAS. The loop seal clearing and loop seal reformation were occurred repeatedly.

  20. The 7.4 per cent cold leg break without accumulator operation

    International Nuclear Information System (INIS)

    Perneczky, L.; Toth, I.; Szabados, L.; Ezsoel, Gy.

    1986-12-01

    A simulation technique for the loss-of-coolant failure analysis of light-water-cooled nuclear reactor is described. It has been used to analyze transient processes during a hypothetical accident and to estimate the effectiveness of built-in safety systems. The model PMK-NHV was established for these types of simulation in the Paks Nuclear Power Plant, Hungary. The first test on this simulation facility is described: a 7.4 per cent cold leg break from full power covering the blowdown phase of the accident. The pre-test analysis using the RELAP4/mod6 computer code, the evaluation of the measured data, the interpretation of the test results and the post-test calculations are presented. The work was performed within the IAEA Standard Problem Exersice (SPE). (R.P.)

  1. ISP - 26 OECD/NEA/CSNI International standard problem n. 26. Rosa-4 LSTF Cold-Leg Small-Break Loca experiment. Comparison report

    International Nuclear Information System (INIS)

    1992-02-01

    This report is the final comparison report for the CSNI ISP-26 which was performed for a 5 pc cold-leg small-break LOCA experiment conducted in the ROSA-IV Large scale test facility (LSTF), and simulation of the thermal-hydraulic response of a pressurized water reactor during a small break loss-of-coolant accident or an operational transient. The facility has an overall scaling factor of 1/48, with hot and cold legs sized to conserve the volume scaling. Both the initial steady-state conditions and the test procedures are designed to minimize the effects of scaling compromises. 10 seconds into the break, the turbine throttle valve was closed at a pressurizer pressure of 12.97 MPa. The turbine bypass was inactive, since loss-of-offsite power was assumed concurrently with the scram. The reactor coolant pumps stopped at 265 seconds. The core was uncovered between 120 seconds and 155 seconds into the break. The comparison report presents all the nineteen submitted calculations. A summary description of the participants as well as the computer codes and input decks used by them is provided

  2. Numerical simulation of thermal stratification in cold legs by using openFOAM

    International Nuclear Information System (INIS)

    Cai, Jiejin; Watanabe, Tadashi

    2010-01-01

    During a small-break loss-of-coolant accident in pressurized water reactors (PWRs), emergency core cooling system (ECCS) is actuated and cold water is injected into cold legs. Insufficient mixing of injected cold water and hot primary coolant results in thermal stratification, which is a matter of concern for evaluation of pressurized thermal shock (PTS) in view of aging and life extension of nuclear power plants. In this study, an open source CFD software, OpenFOAM, is used to simulate mixing and thermal stratification in the cold leg of ROSA/LSTF, which is the largest thermal-hydraulic integral test facility simulating PWR. One of the cold-leg is numerically simulated from the outlet of primary coolant pump to the inlet of downcomer. ECCS water is injected from injection nozzle connected at the top of the cold leg into the steady-state natural circulation flow under high-pressure and high-temperature conditions. The temperature distribution in the cold leg is compared with experimental and FLUENT's results. Effects of turbulent flow models and secondary flow due to the elbow section of the cold leg are discussed for the case with the single-phase natural circulation. Injection into a two-phase stratified flow is also simulated and predictive and numerical capabilities of OpenFOAM are discussed. (author)

  3. Simulation of a postulated 2% cold leg break in Angra 2 nuclear power plant

    International Nuclear Information System (INIS)

    Palmieiri, Elcio Tadeu; Azevedo, Carlos Vicente Goulart de; Aronne, Ivan Dionysio

    2007-01-01

    This paper presents the simulation of a 2% break in the cold leg pipe of Angra 2 nuclear power plant, with the computer code RELAP5/Mod3.3. The main boundary conditions specified for this simulation were: no injection from high pressure injection system; enhanced depressurization of the primary system by opening the pressure operated relief valve (PORV) and the safety relief valve (SRV) when core temperature reaches circa 100 K above saturation; and accumulator injection starting at 2.7 MPa. The specific objectives to be addressed with this simulation are: the core boil-off and dryout at relatively high pressure in the primary system; the phenomena during enhanced primary depressurization; the effectiveness of hot leg accumulator injection into the partially uncovered rod bundle; and the core rewetting. The results obtained were compared with the Lobi A1-93 test, which was performed under the same boundary conditions. This activity was executed in the scope of IAEA research project Evaluation of Uncertainties in the Simulation of Accidents in Angra 2 using RELAP5/MOD3 Code Applying CIAU Methodology (author)

  4. Numerical simulation of thermal stratification in cold legs by using OpenFOAM

    International Nuclear Information System (INIS)

    Cai, Jiejin; Watanabe, Tadashi

    2011-01-01

    During a small-break loss-of-coolant accident in pressurized water reactors (PWRs), emergency core cooling system (ECCS) is actuated and cold water is injected into cold legs. Insufficient mixing of injected cold water and hot primary coolant results in thermal stratification, which is a matter of concern for evaluation of pressurized thermal shock (PTS) in view of aging and life extension of nuclear power plants. In this study, an open source CFD software, OpenFOAM, is used to simulate mixing and thermal stratification in the cold leg of ROSA/LSTF, which is the largest thermal-hydraulic integral test facility simulating PWR. One of the cold-leg is numerically simulated from the outlet of primary coolant pump to the inlet of downcomer. ECCS water is injected from injection nozzle connected at the top of the cold leg into the steady-state natural circulation flow under high-pressure and high-temperature conditions. The temperature distribution in the cold leg is compared with experimental and FLUENT's results. Effects of turbulent flow models and secondary flow due to the elbow section of the cold leg are discussed for the case with the single-phase natural circulation. Injection into a two-phase stratified flow is also simulated and predictive and numerical capabilities of OpenFOAM are discussed. (author)

  5. Data report for ROSA-IV LSTF 10% hot leg break experiment Run SB-HL-02

    International Nuclear Information System (INIS)

    Kukita, Yutaka; Hirata, Kazuo; Gotou, Hiroki

    1990-03-01

    Experimental data for the 10% hot leg break test, Run SB-HL-02, conducted at the ROSA-IV Large Scale Test Facility (LSTF) on June 30, 1987, are presented. This test assumed total failure of both high pressure injection (HPI) and auxiliary feedwater (AFW) systems. The test results were characterized by asymmetric loop responses, flashing in the cold legs and upper downcomer, as well as condensation depressurization in the cold legs following injection of emergency core coolant (ECC) from accumulators. (author)

  6. Counter-current flow limitation at hot leg pipe during reflux condensation cooling after small-break LOCA

    International Nuclear Information System (INIS)

    Jeong, Hae Yong; Ha, Sang Jun; Jo, Yung Jo; Jun, Hwang Yong

    1999-01-01

    The possibility of hot leg flooding is evaluated in case of a small-break loss-of-coolant accident in Korean Next Generation Reactor (KNGR) operating at the core power of 3983 MW normally. The vapor and liquid velocities in hot leg and steam generator tubes are calculated during reflux condensation cooling with the accident scenarios of three typical break sizes, 0.13 %, 1.02 % and 10.19 % cold leg break. The calculated results are compared with the existing flooding correlations. It is predicted that the hot leg flooding is excluded when two steam generators are available. It is also shown that the possibility of hot leg flooding under the operation with one steam generator is very low. Therefore, it can be said that the occurrence of hot leg flooding is unexpected when the reflux condensation cooling is maintained in steam generator tubes

  7. Prediction of Counter-Current Flow Limitation at Hot Leg Pipe During a Small-Break Loca

    Energy Technology Data Exchange (ETDEWEB)

    Jeong, H.Y. [Korea Electric Power Research Institute, Taejeon (Korea)

    2001-07-01

    The possibility of hot leg flooding during reflux condensation cooling after a small-break loss-of-coolant accident in a nuclear power plant is evaluated. The vapor and liquid velocities in hot leg and steam generator tubes are calculated during reflux condensation cooling with the accident scenarios of three typical break sizes, 0.13 %, 1.02 % and 10.19 % cold leg break. The effect of initial water level to counter-current flow limitation is taken into account. It is predicted that the hot leg flooding is precluded when all steam generators are available for heat removal. It is also shown the both hot leg flooding and SG flooding are possible under the operation of one steam generators. Therefore, it can be said that the occurrence of hot leg flooding under reflux condensation cooling is possible when the number of steam generators available for heat removal is limited. (author). 15 refs., 15 figs., 3 tabs.

  8. Data report of ROSA/LSTF experiment SB-CL-32. 1% cold leg break LOCA with SG depressurization and no gas inflow

    International Nuclear Information System (INIS)

    Takeda, Takeshi

    2014-11-01

    An experiment SB-CL-32 was conducted on May 28, 1996 using the Large Scale Test Facility (LSTF) in the Rig of Safety Assessment-V (ROSA-V) Program. The ROSA/LSTF experiment SB-CL-32 simulated a 1% cold leg small-break loss-of-coolant accident in a pressurized water reactor under assumptions of total failure of high pressure injection system and no inflow of non-condensable gas from accumulator (ACC) tanks of emergency core cooling system. Secondary-side depressurization of both steam generators (SGs) as an accident management (AM) action to achieve the depressurization rate of 200 K/h in the primary system was initiated 10 min after the break. After the initiation of AM action, auxiliary feedwater injection into the SG secondary-side was started with some delay. After the onset of AM action, the primary pressure decreased following the SG secondary-side pressure. Core uncovery by core boil-off started with liquid level drop in crossover leg downflow-side. The core liquid level recovered rapidly after first loop seal clearing (LSC). The surface temperature of simulated fuel rod then increased up to 669 K. Core uncovery by core boil-off took place before second LSC induced by steam condensation on ACC coolant injected into cold legs following the primary depressurization. The core liquid level recovered rapidly after the second LSC. The observed maximum fuel rod surface temperature was 772 K. The experiment was terminated when the continuous core cooling was confirmed because of the coolant injection by low pressure injection system after the isolation of ACC system. The obtained data would be useful to define the conditions for counterpart testing of other integral test facilities to address scaling problems through thermal-hydraulic phenomena. This report summarizes the test procedures, conditions and major observation in the ROSA/LSTF experiment SB-CL-32. (author)

  9. The analysis of 14.8 percent cold leg break without the application of hydroaccumulators in the PMK-NHV test facility

    International Nuclear Information System (INIS)

    Szabados, L.; Ezsoel, Gy.; Perneczky, L.

    1990-12-01

    A series of reactor safety tests have been performed in the experimental reactor simulation facility PMK-NHV of the Paks Nuclear Power Plant, Hungary, with and without the use of hydroaccumulator (SIT) operation. 14.8 percent cold leg break simulation experiments are reported without SITs in action, and the measurement results were analyzed using the RELAP5/mod2 computer code. The description of the experiment is followed by the parameter variations and their analysis, together with an interpretation of the measurement results. The lessons from the LOCA simulation tests are evaluated. (R.P.) 10 refs.; 48 figs.; 3 tabs

  10. Assessment of RELAP/MOD3 using BETHSY 6.2TC 6-inch cold leg side break comparative test

    International Nuclear Information System (INIS)

    Chung, Young-Jong; Jeong, Jae-Jun; Chang, Won-Pyo; Kim, Dong-Su

    1996-10-01

    This report presents the results of the RELAP5/MOD3 Version 7j assessment on BETHSY 6.2TC. BETHSY 6.2TC test corresponding to a six inch cold leg break LOCA of the Pressurizer Water Reactor(PWR). The primary objective of the test was to provide reference data of two facilities of different scales (BETHSY and LSTF facility). On the other hand, the present calculation aims at analysis of RELAP5/N4OD3 capability on the small break LOCA simulation, The results of calculation have shown that the RELAP5/MOD3 reasonably predicts occurrences as well as trends of the major phenomena such as primary pressure, timing of loop seal clearing, liquid hold up, etc. However, some disagreements also have been found in the predictions of loop seal clearing, collapsed core water level after loop seal clearing, and accumulator injection behaviors. For better understanding of discrepancies in same predictions, several sensitivity calculations have been performed as well. These include the changes of two-phase discharge coefficient at the break junction and some corrections of the interphase drag term. As result, change of a single parameter has not improved the overall predictions and it has been found that the interphase drag model has still large uncertainties

  11. Cold leg condensation tests. Task C. Steam--water interaction tests

    International Nuclear Information System (INIS)

    Brodrick, J.R.; Loiselle, V.

    1974-03-01

    A report is presented of tests to determine the condensation efficiency of ECC water injected into a quality fluid mixture flowing through the cold leg. In particular, a specific objective was to determine if the mixture of ECC water and quality fluid reached thermodynamic equilibrium before exiting the cold leg. Further, the stability of the ECC water/quality fluid interaction would be assessed by interpretation of thermocouple records and utilization of a section of cold leg piping with view ports to film the interaction whenever possible. The cold leg condensation tests showed complete condensation of the 5 lbm/sec steam quality mixtures in the cold leg by the ECC water flows of the test matrix. The cold leg exit fluid temperature remained below the saturation temperature and had good agreement with the predicted cold leg outlet temperature, calculated assuming total condensation. (U.S.)

  12. Evaluation of a postulated loss of coolant accident (LOCA) due to a 160 cm2 break in a cold leg of Angra 2 nuclear power plant

    International Nuclear Information System (INIS)

    Azevedo, Carlos Vicente Goulart de; Palmieri, Elcio Tadeu; Aronne, Ivan Dionysio

    2002-01-01

    The development of a qualified full nodalization of Angra2 NPP for RELAP5/Mod 3.2.2 gamma, aiming at the evaluation of a comprehensive number of accidents and transients, thus providing suitable safety analysis support for licensing purposes, is being carried out within the framework of CNEN internal technical cooperation, involving some of its institutes (CDTN, IPEN and IEN) and the Reactors Coordination (CODRE). This work presents a simulation of a postulated Angra2 small cold leg break loss of coolant accident (SBLOCA). A 160 cm 2 break is supposed to occur at one cold leg between the main coolant pump and the reactor vessel and is described in the Angra2 Final Safety Analysis Report, section 15.6.4.1.3.4. The simulation of several types of transients and accidents is necessary to verify the adequate performance of the modeled logic and systems. In general, the analysis of such and accident allows to demonstrate the safety Injection System performance and the reliable transition between the high pressure safety injection, the accumulator injection and the residual heat removal phases. Furthermore, it is assumed that some components are out of service due to fail or repair in order to make a conservative analysis. The results showed a compatible behavior of the molded systems and that the simulated Emergency Core Cooling System was able to provide sufficient cooling to avoid any damage to the core. (author)

  13. TRAC analysis of an 80% pump-side, cold-leg, large-break loss-of-coolant accident for the Westinghouse AP600 advanced reactor design

    International Nuclear Information System (INIS)

    Lime, J.F.; Boyack, B.E.

    1996-01-01

    An updated TRAC 80% pump-side, cold-leg, large-break (LB) loss-of-coolant accident (LOCA) has been calculated for the Westinghouse AP600 advanced reactor design. The updated calculation incorporates major code error corrections, model corrections, and plant design changes. The break size and location were calculated by Westinghouse to be the most severe LBLOCA for the AP600 design. The LBLOCA transient was calculated to 280 s, which is the time of in-containment refueling water-storage-tank injection. All fuel rods were quenched completely by 240 s. Peak cladding temperatures (PCTs) were well below the licensing limit of 1,478 K (2,200 F) but were very near the cladding oxidation temperature of 1,200 K (1,700 F). Transient event times and PCTs for the TRAC calculation were in reasonable agreement with those calculated by Westinghouse using their WCOBRA/TRAC code. However, there were significant differences in the detailed phenomena calculated by the two codes, particularly during the blowdown and refill periods. The reasons for these differences are still being investigated

  14. Water-hammer in the cold leg during an SBLOCA due to cold ECCS injection

    International Nuclear Information System (INIS)

    Ortiz, M.G.; Ghan, L.S.

    1991-01-01

    Water-hammer might occur in the cold leg of pressurized water reactors (PWR) during small break loss-of-coolant accidents (SBLOCA's), when cold emergency core cooling system (ECCS) water is injected into a pipe that may be partially filled with saturated steam. The water may mix with the steam and cause it to condense abruptly. Depending on the flow regime present, slugs of liquid may then be accelerated towards each other or against the piping structure. The possibility of this phenomenon is of concern to us because it may become a dominant phenomenon and change the character of the transient. In performing the code scaling, applicability, and uncertainty study (CSAU) on a SBLOCA scenario, we had to examine the possibility that the transient being analyzed could experience water-hammer and thus depart from the scope of the study. Two criteria for water-hammer initiation were investigated and tested using a RELAP5/MOD3 simulation of the transient. Our results indicated a very low likelihood of occurrence of the phenomenon. 8 refs., 6 figs

  15. LOFT/LP-SB-3, Loss of Fluid Test, Cold Leg Break LOCA, No High Pressure injection System (HPIS)

    International Nuclear Information System (INIS)

    1989-01-01

    1 - Description of test facility: The LOFT Integral Test Facility is a scale model of a LPWR. The intent of the facility is to model the nuclear, thermal-hydraulic phenomena which would take place in a LPWR during a LOCA. The general philosophy in scaling coolant volumes and flow areas in LOFT was to use the ratio of the LOFT core [50 MW(t)] to a typical LPWR core [3000 MW(t)]. For some components, this factor is not applied; however, it is used as extensively as practical. In general, components used in LOFT are similar in design to those of a LPWR. Because of scaling and component design, the LOFT LOCA is expected to closely model a LPWR LOCA. 2 - Description of test: The sixth OECD LOFT experiment was conducted on 5 March 1984. It simulated a 1.8-in cold leg break LOCA with no HPIS available. This experiment was designed mainly for investigation of plant recovery effectiveness using secondary bleed and feed during core uncover and addressed accumulator injection at low pressure differentials. 3 - Experimental limitations or shortcomings: Short core and steam generator, excessive core bypass, other scaling compromises, and lack of adequate measurements in certain areas

  16. Pressurized thermal shock. CNA-I behavior when a hot leg breaks of 50 cm2 is produced

    International Nuclear Information System (INIS)

    Rosso, Ricardo D.; Ventura, Mirta A.

    2002-01-01

    Pressurized thermal shock (PTS) phenomena in the CNA-I pressurize heavy water reactor is analyzed in this paper. The initiating event is a hypothetical 50 cm 2 break of the line connecting the pressurizer and the primary system. The calculation procedure for obtaining the local thermal-hydraulic parameters in the reactor pressure vessel downcomer is described firstly. Results obtained lead to conclusions in different subjects. The first conclusion is that a simple tool of easy application is available to analyze PTS phenomena in cases of breaks in the primary system in cold and hot legs. This methodology is fully independent of the methodology utilized by the Utility. Another important conclusion comes from the analysis of the temperature evolution of the fluid below the cold leg level in the RPV downcomer, as a function of the T HPI temperature of the TJ system injected water from. It is also concluded that the results obtained with the methodology adopted agree with the ones obtained with the methodologies validated against experiments in the UPTF facility. It is possible to observe that when T HPI increase, the conditions suitable for PTS occurrence in a LOCA accident tend to diminish. The maximum value to the T HPI may be fixed from the maximum temperature allowed to preserve the structural integrity of the fuel cladding. (author)

  17. Reconstruction of core inlet temperature distribution by cold leg temperature measurements

    International Nuclear Information System (INIS)

    Saarinen, S.; Antila, M.

    2010-01-01

    The reduced core of Loviisa NPP contains 33 thermocouple measurements measuring the core inlet temperature. Currently, these thermocouple measurements are not used in determining the inlet temperature distribution. The average of cold leg temperature measurements is used as inlet temperature for each fuel assembly. In practice, the inlet temperature distribution is not constant. Thus, using a constant inlet temperature distribution induces asymmetries in the measured core power distribution. Using a more realistic inlet temperature distribution would help us to reduce virtual asymmetries of the core power distribution and increase the thermal margins of the core. The thermocouples at the inlet cannot be used directly to measure the inlet temperature accurately because the calibration of the thermocouples that is done at hot zero power conditions is no longer valid at full power, when there is temperature change across the core region. This is due to the effect of neutron irradiation on the Seebeck coefficient of the thermocouple wires. Therefore, we investigate in this paper a method to determine the inlet temperature distribution based on the cold leg temperature measurements. With this method we rely on the assumption that although the core inlet thermocouple measurements do not measure the absolute temperature accurately they do measure temperature changes with sufficient accuracy particularly in big disturbances. During the yearly testing of steam generator safety valves we observe a large temperature increase up to 12 degrees in the cold leg temperature. The change in the temperature of one of the cold legs causes a local disturbance in the core inlet temperature distribution. Using the temperature changes observed in the inlet thermocouple measurements we are able to fit six core inlet temperature response functions, one for each cold leg. The value of a function at an assembly inlet is determined only by the corresponding cold leg temperature disturbance

  18. Best estimate small break LOCA analysis for KNGR SIS optimization

    International Nuclear Information System (INIS)

    Song, JIn Ho; Lim, Hong Sik; Bae, Kyoo Hwan; Lee, Joon

    1996-01-01

    The KNGR has an advanced ECCS design feature which employs four mechanically-separated SI trains where each train consisting of one HPSI pump and one SIT injects ECC water directly into the reactor vessel downcomer annulus. To demonstrate that the KNGR ECCS design features meet the EPRI ALWR requirements of no core uncovery for a break of up to 6 inch diameter, small break LOCA cases with various break sizes were analyzed using a best-estimate analytical procedure. Two kinds of break locations are considered: cold leg and DVI line breaks. It was observed that the KNGR ECCS design can tolerate a cold leg break of up to 10 inches with no core uncovery. However, since DVI line break with 6 inch diameter undergoes slight core uncovery, further investigation is required for KNGR SIS optimization

  19. Blind-blind prediction by RELAP5/MOD1 for a 0.1% very small cold-leg break experiment at ROSA-IV large-scale test facility

    International Nuclear Information System (INIS)

    Koizumi, Y.; Kumamaru, H.; Kukita, Y.; Kawaji, M.; Osakabe, M.; Schultz, R.R.; Tanaka, M.; Tasaka, K.

    1986-01-01

    The large-scale test facility (LSTF) of the Rig of Safety Assessment No. 4 (ROSA-IV) program is a volumetrically scaled (1/48) pressurized water reactor (PWR) system with an electrically heated core used for integral simulation of small break loss-of-coolant accidents (LOCAs) and operational transients. The 0.1% very small cold-leg break experiment was conducted as the first integral experiment at the LSTF. The test provided a good opportunity to truly assess the state-of-the-art predictability of the safety analysis code RELAP5/MODI CY18 through a blind-blind prediction of the experiment since there was no prior experience in analyzing the experimental data with the code; furthermore, detailed operational characteristics of LSTF were not yet known. The LOCA transient was mitigated by high-pressure charging pump injection to the primary system and bleed and feed operation of the secondary system. The simulated reactor system was safely placed in hot standby condition by engineered safety features similar to those on a PWR. Natural circulation flow was established to effectively remove the decay heat generated in the core. No cladding surface temperature excursion was observed. The RELAP5 code showed good capability to predict thermal-hydraulic phenomena during the very small break LOCA transient. Although all the information needed for the analysis by the RELAP5 code was obtained solely from the engineering drawings for fabrication and the operational specifications, the code predicted key phenomena satisfactorily

  20. Study on severe accident induced by large break loss of coolant accident for pressureized water reactor

    International Nuclear Information System (INIS)

    Zhang Longfei; Zhang Dafa; Wang Shaoming

    2007-01-01

    Using the best estimate computer code SCDAP/RELAP5/MOD3.2 and taking US Westinghouse corporation Surry nuclear power plant as the reference object, a typical three-loop pressurized water reactor severe accident calculation model was established and 25 cm large break loss of coolant accident (LBLOCA) in cold and hot leg of primary loop induced core melt accident was analyzed. The calculated results show that core melt progression is fast and most of the core material melt and relocated to the lower plenum. The lower head of reactor pressure vessel failed at an early time and the cold leg break is more severe than the hot leg break in primary loop during LBLOCA. (authors)

  1. Development of analysis methodology for hot leg break mass and energy release

    International Nuclear Information System (INIS)

    Song, Jin Ho; Kim, Cheol Woo; Kwon, Young Min; Kim, Sook Kwan

    1995-04-01

    A study for the development of an analysis methodology for hot leg break mass and energy release is performed. For the blowdown period a modified CEFLASH-4A methodology is suggested. For the post blowdown period a modified CONTRAST boil-off model is suggested. By using these computer code improved mass and energy release data are generated. Also, a RELAP5/MOD3 analysis for finally the FLOOD-3 computer code has been modified for use in the analysis of hot leg break. The results of analysis using modified FLOOD-3 are reasonable as we expected and their trends are good. 66 figs., 8 tabs. (Author) .new

  2. ROSA/LSTF Test and RELAP5 Analyses on PWR Cold Leg Small-Break LOCA with Accident Management Measure and PKL Counterpart Test

    Energy Technology Data Exchange (ETDEWEB)

    Takeda, Takeshi; Ohtsu, Iwao [Nuclear Safety Research Center, Japan Atomic Energy Agency, Tokaimura (Japan)

    2017-08-15

    An experiment using the Primaerkreislaeufe Versuchsanlage (PKL) was performed for the OECD/NEA PKL-3 Project as a counterpart to a previous test with the large-scale test facility (LSTF) on a cold leg small-break loss-of-coolant accident with an accident management (AM) measure in a pressurized water reactor. Concerning the AM measure, the rate of steam generator (SG) secondary-side depressurization was controlled to achieve a primary depressurization rate of 200 K/h as a common test condition; however, the onset timings of the SG depressurization were different from each other. In both tests, rapid recovery started in the core collapsed liquid level after loop seal clearing, which caused whole core quench. Some discrepancies appeared between the LSTF and PKL test results for the core collapsed liquid level, the cladding surface temperature, and the primary pressure. The RELAP5/MOD3.3 code predicted the overall trends of the major thermal-hydraulic responses observed in the LSTF test well, and indicated a remaining problem in the prediction of primary coolant distribution. Results of uncertainty analysis for the LSTF test clarified the influences of the combination of multiple uncertain parameters on peak cladding temperature within the defined uncertain ranges.

  3. ROSA/LSTF Test and RELAP5 Analyses on PWR Cold Leg Small-Break LOCA with Accident Management Measure and PKL Counterpart Test

    Directory of Open Access Journals (Sweden)

    Takeshi Takeda

    2017-08-01

    Full Text Available An experiment using the Primӓrkreislӓufe Versuchsanlage (PKL was performed for the OECD/NEA PKL-3 Project as a counterpart to a previous test with the large-scale test facility (LSTF on a cold leg small-break loss-of-coolant accident with an accident management (AM measure in a pressurized water reactor. Concerning the AM measure, the rate of steam generator (SG secondary-side depressurization was controlled to achieve a primary depressurization rate of 200 K/h as a common test condition; however, the onset timings of the SG depressurization were different from each other. In both tests, rapid recovery started in the core collapsed liquid level after loop seal clearing, which caused whole core quench. Some discrepancies appeared between the LSTF and PKL test results for the core collapsed liquid level, the cladding surface temperature, and the primary pressure. The RELAP5/MOD3.3 code predicted the overall trends of the major thermal-hydraulic responses observed in the LSTF test well, and indicated a remaining problem in the prediction of primary coolant distribution. Results of uncertainty analysis for the LSTF test clarified the influences of the combination of multiple uncertain parameters on peak cladding temperature within the defined uncertain ranges.

  4. Analysis of Semiscale Mod-1 integral test with asymmetrical break (Test S-29-1)

    International Nuclear Information System (INIS)

    Langerman, M.A.

    1977-03-01

    Selected experimental data obtained from Semiscale Mod-1 cold leg break Test S-29-1 and results obtained from analytical codes are analyzed. This test was the first integral blowdown reflood test conducted with the Mod-1 system and was a special test designed specifically to evaluate the sensitivity of the early Mod-1 core thermal response (0 to 5 sec after rupture) to the magnitude and direction of the core flow. To achieve this specific objective in Test S-29-1, the vessel side break area was reduced to approximately one-half the scaled break area associated with a 200 percent cold leg break test. The reduction in break area significantly reduced the core flow reversal that took place immediately after rupture and resulted in periods of positive core flow in the early portion of the test. The results obtained from this test are compared with results obtained from a 200 percent cold leg break test and the effect of core flow on early core thermal response is evaluated. Since Test S-29-1 was the first integral blowdown reflood test conducted with the Mod-1 system, data are also presented through the reflood stage of the test and the results are analyzed. The test data and the core thermal response calculated with the RELAP4 code are also compared

  5. Analysis of breaks in pipe connections to the hot leg and to the loop seal in the primary system of Ringhals 2 PWR

    International Nuclear Information System (INIS)

    Nilsson, L.; Sjoeberg, A.

    1987-01-01

    Analysis has been made of seven different cases of breaks in pipes connected to the hot leg and to the loop seal in Ringhals 2 PWR. The pipes, in which guillotine breaks are postulated, have nominal diameters ranging from 1 to 14 inches. The purpose of the analysis is to supplement the basis for a review of the inspection procedures for the safety of pressure vessels prescribed by SKI. A similar analysis already exists concerning breaks in the cold leg connections. The analysis has been made using the thermal hydraulic computer code RELAPS/MOD2 and with best estimate assumptions. This means that normal operating conditions have been adopted for the input to the calculations. However, the capacity of the safety injection system was assumed to be reduced by having one pump not operating each of the low pressure and high pressure safety injection system. The results of the analysis are presented in tables and as computer plots. The analysis shows that the consequences with respect to increased fuel rod and cladding temperatures are quite harmless. Only the two cases with the largest break sizes lead to critical heat flux (CHF) and increased temperatures for the hottest rods in the core. The peak cladding temperature was 636 degrees C for the 12 inch break. In both cases rewetting occurred within 25 s of accident initiation. In the cases with breaks in connections of 6 inch diameter and smaller the RELAP5 calculations indicated a substantial margin to CHF throughout the transient. (authors)

  6. Analysis of unmitigated large break loss of coolant accidents using MELCOR code

    Science.gov (United States)

    Pescarini, M.; Mascari, F.; Mostacci, D.; De Rosa, F.; Lombardo, C.; Giannetti, F.

    2017-11-01

    In the framework of severe accident research activity developed by ENEA, a MELCOR nodalization of a generic Pressurized Water Reactor of 900 MWe has been developed. The aim of this paper is to present the analysis of MELCOR code calculations concerning two independent unmitigated large break loss of coolant accident transients, occurring in the cited type of reactor. In particular, the analysis and comparison between the transients initiated by an unmitigated double-ended cold leg rupture and an unmitigated double-ended hot leg rupture in the loop 1 of the primary cooling system is presented herein. This activity has been performed focusing specifically on the in-vessel phenomenology that characterizes this kind of accidents. The analysis of the thermal-hydraulic transient phenomena and the core degradation phenomena is therefore here presented. The analysis of the calculated data shows the capability of the code to reproduce the phenomena typical of these transients and permits their phenomenological study. A first sequence of main events is here presented and shows that the cold leg break transient results faster than the hot leg break transient because of the position of the break. Further analyses are in progress to quantitatively assess the results of the code nodalization for accident management strategy definition and fission product source term evaluation.

  7. Integrity assessment of the cold leg piping system in a PWR

    International Nuclear Information System (INIS)

    Mayfield, M.E.; Leis, B.N.

    1981-01-01

    The purpose of this paper is to examine the integrity of a nuclear piping system, designed in accordance with Section III, in the context of a damage tolerance analysis procedure. Such a procedure directly addresses the defects and cyclic loadings that are responsible for the above noted exceptions. The analysis and results reported here are for a fatigue life analysis of the Cold Leg piping in a PWR. This piping system is particularly important from a safety standpoint since a large break is a possible initiator of a core meltdown accident. The analysis employs LEFM concepts to determine the time between the initial start-up and (1) formation of a leak, (2) detection of the leak, and (3) the final fracture of the piping. Both longitudinal and circumferential defects are considered. The defects are assumed to propagate from the pipe I.D. in a self-similar manner. Inputs to the analysis were derived from information supplied by plant operators and vendors, published data, and 'expert opinions'. The life was computed using a linear damage accumulation. (orig./GL)

  8. NPP Krsko small break LOCA analysis

    International Nuclear Information System (INIS)

    Mavko, B.; Petelin, S.; Peterlin, G.

    1987-01-01

    Parametric analysis of small break loss of coolant accident for the Krsko NPP was calculated by using RELAP5/MOD1 computer code. The model that was used in our calculations has been improved over several years and was previously tested in simulation (s) of start-up tests and known NPP Krsko transients. In our calculations we modelled automatic actions initiated by control, safety and protection systems. We also modelled the required operator actions as specified in emergency operating instructions. In small-break LOCA calculations, we varied break sizes in the cold leg. The influence of steam generator tube plugging on small break LOCA accidents was also analysed. (author)

  9. Comparisons of TRAC-PF-1 calculations with semiscale Mod-3 small-break tests S-SB-P1 and S-SB-P7

    International Nuclear Information System (INIS)

    Sahota, M.S.

    1982-01-01

    Semiscale Tests S-SB-P1 and S-SB-P7 conducted in the Semiscale Mod-3 facility at the Idaho National Engineering Laboratory are analyzed using the latest released version of the Transient Reactor Analysis Code (TRAC-PF1). The results are used to assess TRAC-PF1 predictions of thermal-hydraulic phenomena and the effects of break size and pump operation on system response during slow transients. Tests S-SB-P1 and S-SB-P7 simulated an equivalent pressurized-water-reactor (PWR) 2.5% communicative cold-leg break for early and late pump trips, respectively, with only high-pressure injection (HPI) into the cold legs. The parameters examined include break flow, primary-system pressure response, primary-system mass distribution, and core characteristics

  10. Human thermal responses during leg-only exercise in cold water.

    Science.gov (United States)

    Golden, F S; Tipton, M J

    1987-10-01

    1. Exercise during immersion in cold water has been reported by several authors to accelerate the rate of fall of core temperature when compared with rates seen during static immersion. The nature of the exercise performed, however, has always been whole-body in nature. 2. In the present investigation fifteen subjects performed leg exercise throughout a 40 min head-out immersion in water at 15 degrees C. The responses obtained were compared with those seen when the subjects performed an identical static immersion. 3. Aural and rectal temperatures were found to fall by greater amounts during static immersion. 4. It is concluded that 'the type of exercise performed' should be included in the list of factors which affect core temperature during cold water immersion.

  11. Simulation of the SPE-4 small-break loss-of-coolant accident

    International Nuclear Information System (INIS)

    Cebull, P.; Hassan, Y.A.

    1993-01-01

    A small-break loss of coolant accident (SBLOCA) conducted at the PMK-2 integral test facility was analyzed using RELAP5/MOD3. 1. The experiment simulated a 7.4% break in the cold leg of a VVER-440/213-type nuclear power plant as part of the International Atomic Energy Agency's Fourth Standard Problem Exercise (SPE-4). The VVER design differs from pressurized water reactors (PWRS) of western origin, primarily in its use of horizontal steam generators, hot- and cold-leg loop seals, and safety injection tanks. Because of these differences, it will exhibit somewhat different transient behavior than most PWRS. The PMK-2 test facility, located at the KFKI Atomic Energy Research Institute (AEKI), is a scale model of the Paks nuclear power plant in Hungary with scaling factors of 1:2070 in power and volume and 1:1 in elevation. Primarily used to study SBLOCAs and natural circulation behavior of VVER reactors, it has been used in three previous SPEs

  12. Analysis of a large break LOCA in the cold leg of the WWER-440/W-213 plant Griefswald, Unit 5

    International Nuclear Information System (INIS)

    Horche, W.

    1993-01-01

    The Gessellschaft fur Anlagen und Reaktorsicherheit (GRS) has performed a safety evaluation of the nuclear power plant (NPP) Greifswald, unit 5, of the Soviet type WWER-440/W-213, in cooperation with the French Institute de Protection of de Surete Nucleaire (IPSN) and other partners. Within this project an independent accident analysis is performed by GRS in order to assess the results of existing analysis and to supplement them. In this paper the analysis of the double-ended guillotine break (DEGB) of one cold leg of the main circulation pipe is described. The major objective of the calculation was the investigation of the accident sequence with reduced availability of the emergency core cooling system (single failure criterion). In addition, the simultaneous loss of onsite and offsite power and the failure of scram were assumed. The thermal-hydraulic system code ATHLET/FLUT, developed at GRS and already applied for the safety analysis of several WWER plants, was chosen again. The pressure in the confinement, the back pressure for the discharge model, was calculated as a function of time for this accident separately with GRS-Code RALOC. Furthermore, it was necessary to model the local concentration of direct accumulator injection into the reactor vessel with the help of a special two-channel model of the core and upper plenum. For this model, results were considered obtained from the 1:1 scaled test facility UPTF. It was assumed that only 25% of the upper plenum and core volume is directly penetrated by the injected water. The DEGB was defined in that loop, which is connected with one of three low-pressure injection subsystems. This means that this injected water flows towards the leak without passing the core. As single failure the failure of one of three diesel generators was assumed. The full paper will contain nodalization schemes, which are generated by the ATHLET-Input-Grafic

  13. ISP-27 OECD/NEA/CSNI International Standard Problem n.27. Bethsy experiment 9.1 B. 2. cold leg break without HPSI and with delayed ultimate procedure. Comparison report. Volume 1 + 2

    International Nuclear Information System (INIS)

    1992-11-01

    This report is the final comparison report for ISP-27, a blind problem which is based on the BETHSY test 9.1b performed in december 1989 at the Nuclear Research Center in Grenoble (France). The BETHSY integral test facility is a scaled down model of a 3 loop 900 e MW FRAMATOME PWR; the overall scaling factor applied to every volume, mass flowrate and power level is close to 1/100, while elevations are 1/1 in order to preserve the gravitational heads. The cold leg break is combined with the High Pressure Injection System (HPIS) failure. In that case, the state oriented approach requires operators to start an Ultimate Procedure, which consists in fully opening the Steam Generator (SG) atmospheric dumps as soon as they are informed of the unavailability of the HPIS. The presently studied scenario assumes a delayed application of this procedure, which is started only when the core outlet temperature rises significantly higher than the saturation temperature. The BETHSY Test 9.1b addresses, besides typical problems relevant to Small Break Loss Of Coolant Accidents (SBLOCA) such as critical 2-phase flow, loop seal clearing, heat-transfer during boil-off or accumulator injection, specific aspects related to the fast depressurization (primary to secondary and structural heat transfer), uncovered core behavior when intense condensation takes place in the SG, and primary side refilling by the Low Pressure Injection System (LPIS)

  14. Estimation of break location and size for loss of coolant accidents using neural networks

    International Nuclear Information System (INIS)

    Na, Man Gyun; Shin, Sun Ho; Jung, Dong Won; Kim, Soong Pyung; Jeong, Ji Hwan; Lee, Byung Chul

    2004-01-01

    In this work, a probabilistic neural network (PNN) that has been applied well to the classification problems is used in order to identify the break locations of loss of coolant accidents (LOCA) such as hot-leg, cold-leg and steam generator tubes. Also, a fuzzy neural network (FNN) is designed to estimate the break size. The inputs to PNN and FNN are time-integrated values obtained by integrating measurement signals during a short time interval after reactor scram. An automatic structure constructor for the fuzzy neural network automatically selects the input variables from the time-integrated values of many measured signals, and optimizes the number of rules and its related parameters. It is verified that the proposed algorithm identifies very well the break locations of LOCAs and also, estimate their break size accurately

  15. Case study: Investigating the causes of temperature breaks in South African summer fruit export cold chains

    CSIR Research Space (South Africa)

    Goedhals-Gerber, LL

    2016-08-01

    Full Text Available This study investigated the causes and extent of temperature breaks in the South African summer fruit export cold chain from the pack house to the vessel. Numerous causes of temperature breaks throughout the cold chain were found, resulting in many...

  16. Analyzing the loss of coolant accident in PWR nuclear reactors with elevation change in cold leg by RELAP5/MOD3.2 system code

    International Nuclear Information System (INIS)

    Kheshtpaz, H.; Alison, C.

    2006-01-01

    As, the Russian designed VVER-1000 reactor of the Bushehr Nuclear Power Plant by taking into account the change from German technology to that of Russian technology, and with the design of elevation change in the cold legs has been developed; therefore safety assessment of these systems for loss of coolant accident in elevation change in the cold legs and comparison results for non change elevation in the cold legs for a typical reactor (normal design of nuclear reactors) is the main important factor to be considered for the safe operation. In this article, the main objective is the simulation of the loss of coolant accident scenario by the RELAP5/MOD3.2 code in two different cases; first, the elevation change in the cold legs, and the second, non change in it. After comparing and analyzing these two code calculations the results have been generalized for a new design feature of Bushehr reactor. The design and simulation of the elevation change in the cold legs process with RELAP5/MOD3.2 code for PWR reactor is performed for the first time in the country, where it is introducing several important results in this respect

  17. Identification of flow regimes and heat transfer modes in Angra-2 core during the simulation of the small break loss of coolant accident of 250 cm2 in the cold leg of primary loop using RELAP5 code

    International Nuclear Information System (INIS)

    Borges, Eduardo M.; Sabundjian, Gaiane

    2017-01-01

    The aim of this paper is to identify the flow regimes, the heat transfer modes, and the correlations used by RELAP5/MOD3.2. gamma code in Angra-2 during the Small-Break Loss-of-Coolant Accident (SBLOCA) with a 250cm 2 of rupture area in the cold leg of primary loop. The Chapter 15 of the Final Safety Analysis Report of Angra-2 (FSAR-A2) reports this specific kind of accident. The results from this work demonstrated the several flow regimes and heat transfer modes that can be present in the core of Angra-2 during the postulated accident. The results obtained for Angra-2 nuclear reactor core during the postulated accident were satisfactory when compared with the FSAR-A2. Additionally, the results showed the correct actuation of the ECCS guaranteeing the integrity of the reactor core. (author)

  18. Improvement of flavor and viscosity in hot and cold break tomato juice and sauce by peel removal.

    Science.gov (United States)

    Mirondo, Rita; Barringer, Sheryl

    2015-01-01

    Tomatoes are typically not peeled before being made into juice but the peels contain enzymes that affect the odor, flavor, and viscosity of the juice. The peels are removed in the finisher, but their presence during the break process may affect quality. Juice was processed from peeled and unpeeled tomatoes using hot or cold break. The juices were pasteurized by high temperature short time (HTST), low temperature long time (LTLT), or with a retort. The control samples were treated with 10% calcium chloride to stop enzymatic activity in the juice. Sauce was made from juice and the tomato products were analyzed for volatiles, color, viscosity, and by sensory. Cold break juice made with peel contained higher levels of some lipoxygenase-, carotenoid-, and amino acid-derived volatiles, than the juice made without peel. Because of the lack of enzyme activity, hot break juices had lower levels of these volatiles and there was no significant difference between hot break juices made with and without peel. CaCl2 -treated and HTST juice had higher levels of most of the volatiles than LTLT, including the lipoxygenase-derived volatiles. The presence of peel produced a significant decrease in the viscosity of the cold break juice and sauce. There was no significant difference in the hue angle, total soluble solids, pH, titratable acidity, and vitamin C for most of the treatments. The texture, flavor, and overall liking of cold break juice made without peel were preferred over cold break juice made with peel whereas the color was less preferred. Between the sauces no significant differences in preference were obtained. © 2014 Institute of Food Technologists®

  19. Natural Cold Baryogenesis from Strongly Interacting Electroweak Symmetry Breaking

    CERN Document Server

    Konstandin, Thomas

    2011-01-01

    The mechanism of "cold electroweak baryogenesis" has been so far unpopular because its proposal has relied on the ad-hoc assumption of a period of hybrid inflation at the electroweak scale with the Higgs acting as the waterfall field. We argue here that cold baryogenesis can be naturally realized without the need to introduce any slow-roll potential. Our point is that composite Higgs models where electroweak symmetry breaking arises via a strongly first-order phase transition provide a well-motivated framework for cold baryogenesis. In this case, reheating proceeds by bubble collisions and we argue that this can induce changes in Chern-Simons number, which in the presence of new sources of CP violation commonly lead to baryogenesis. We illustrate this mechanism using as a source of CP violation an effective dimension-six operator which is free from EDM constraints, another advantage of cold baryogenesis compared to the standard theory of electroweak baryogenesis. Our results are general as they do not rely on...

  20. Updated TRAC analysis of an 80% double-ended cold-leg break for the AP600 design

    International Nuclear Information System (INIS)

    Lime, J.F.; Boyack, B.E.

    1995-01-01

    An updated TRAC 80% large-break loss-of-coolant accident (LBLOCA) has been calculated for the Westinghouse AP600 advanced reactor design, The updated calculation incorporates major code error corrections, model corrections, and plant design changes. The 80% break size was calculated by Westinghouse to be the most severe large-break size for the AP600 design. The LBLOCA transient was calculated to 144 s. Peak cladding temperatures (PCTS) were well below the Appendix K limit of 1,478 K (2,200 F), but very near the cladding oxidation temperature of 1,200 K (1,700 F). Transient event times and PCT for the TRAC calculation were in reasonable agreement with those calculated by Westinghouse using their WCOBRA/TRAC code. However, there were significant differences in the detailed phenomena calculated by the two codes, particularly during the blowdown phase. The reasons for these differences are still being investigated. Additional break sizes and break locations need to be analyzed to confirm the most severe break postulated by Westinghouse

  1. Identification of flow regimes and heat transfer modes in Angra-2 core during the simulation of the small break loss of coolant accident of 250 cm{sup 2} in the cold leg of primary loop using RELAP5 code

    Energy Technology Data Exchange (ETDEWEB)

    Borges, Eduardo M.; Sabundjian, Gaiane, E-mail: borges.em@hotmail.com, E-mail: gdjian@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNE-SP), Sao Paulo, SP (Brazil)

    2017-07-01

    The aim of this paper is to identify the flow regimes, the heat transfer modes, and the correlations used by RELAP5/MOD3.2. gamma code in Angra-2 during the Small-Break Loss-of-Coolant Accident (SBLOCA) with a 250cm{sup 2} of rupture area in the cold leg of primary loop. The Chapter 15 of the Final Safety Analysis Report of Angra-2 (FSAR-A2) reports this specific kind of accident. The results from this work demonstrated the several flow regimes and heat transfer modes that can be present in the core of Angra-2 during the postulated accident. The results obtained for Angra-2 nuclear reactor core during the postulated accident were satisfactory when compared with the FSAR-A2. Additionally, the results showed the correct actuation of the ECCS guaranteeing the integrity of the reactor core. (author)

  2. A study on the effect of fluidic device installed in a safety injection tank on thermal-hydraulic phenomena of large break loss of coolant accident

    International Nuclear Information System (INIS)

    Chung, Young Jong; Bae, Kyoo Hwan; Song, Jin Ho; Sim, Suk Ku; Park, Jong Kyun

    1999-03-01

    The performance of the Safety Injection Tank (SIT) with fluidic device (advanced SIT) is analyzed for the large break loss of coolant accident (LBLOCA) using RELAP5/MOD3.1-KREM. First the case is analyzed using the conventional SIT. Among various cases the case with 4-split downcomer, discharge coefficient Cd=0.6, MCP trip with reactor trip and break location of cold leg discharge side with the pressurizer is found to be the most limiting case. For the same condition, the advanced SIT results the similar PCT, however it can maintain adequately the liquid level in the downcomer. By changing the ECCS location from the current injection to the cold leg elevations, PCT is improved by 75 K. (Author). 6 refs., 4 tabs., 54 figs

  3. Effects of the reactor coolant pumps following a small break in a Westinghouse PWR

    International Nuclear Information System (INIS)

    Koenig, J.E.

    1983-10-01

    Numerical simulations of the thermal-hydraulic events following a small cold-leg break in a Westinghouse pressurized water reactor were performed to address the pumps-on/off issue. The mode of pump operation was varied in each calculation to ascertain the optimum mode. It was found that pump operation was not critical for this break size and location because the fuel rods remained cool in all accidents analyzed. In terms of system mass, however, it was preferable to leave the pumps in operation

  4. Modelling for great breaks accident analysis in the primary system of Angra 1 reactor

    International Nuclear Information System (INIS)

    Serrano, M.A.B.; Vanni, E.A.

    1981-01-01

    An analysis is made for a break in the cold leg, of the guillotine type with discharge coefficient C sub(D)=1.0, for the Angra 1 reactor. The computer codes, geometrical models and options used are described. A comparison between the method used and the requirements in the Appendix K of 10 CRF 50 is done. (Author) [pt

  5. Analysis of cold leg LOCA with failed HPSI by means of integrated safety assessment methodology

    International Nuclear Information System (INIS)

    Gonzalez-Cadelo, J.; Queral, C.; Montero-Mayorga, J.

    2014-01-01

    Highlights: • Results of ISA for considered sequences endorse EOPs guidance in an original way. • ISA allows to obtain accurate available times for accident management actions. • RCP-trip adequacy and available time for beginning depressurization are evaluated. • ISA minimizes the necessity of expert judgment to perform safety assessment. - Abstract: The integrated safety assessment (ISA) methodology, developed by the Spanish Nuclear Safety Council (CSN), has been applied to a thermal–hydraulic analysis of cold leg LOCA sequences with unavailable High Pressure Injection System in a Westinghouse 3-loop PWR. This analysis has been performed with TRACE 5.0 patch 1 code. ISA methodology allows obtaining the Damage Domain (the region of space of parameters where a safety limit is exceeded) as a function of uncertain parameters (break area) and operator actuation times, and provides to the analyst useful information about the impact of these uncertain parameters in safety concerns. In this work two main issues have been analyzed: the effect of reactor coolant pump trip and the available time for beginning of secondary-side depressurization. The main conclusions are that present Emergency Operating Procedures (EOPs) are adequate for managing this kind of sequences and the ISA methodology is able to take into account time delays and parameter uncertainties

  6. Analysis of ATLAS Cold Leg SBLOCA Using SPACE Code

    International Nuclear Information System (INIS)

    Kang, Doo Hyuk; Suh, Jae Seung; Kim, Se Yun

    2012-01-01

    SPACE Code has been developed to predict the thermal-hydraulic responses of nuclear steam supply system to the anticipated transients and postulated accidents and adopted advanced physical modeling of two-phase flows, mainly two-fluid, three-field models that comprise gas, continuous liquid, and droplet fields and has the capability to simulate 3D effects by the use of structured and/or non-structured meshes. In this paper, a cold-leg SBLOCA which is the experiment, SB-CL-09, of the ATLAS integral effect test facility during the second domestic stand problem (DSP-02) was analyzed. The results were compared with those of MARS-KS code simulations. The SPACE code with a 1.0 version was released by KHNP in 2012. The analysis has been performed in a desktop PC with Windows 7 environment

  7. Experiment data report for Semiscale Mod-1 Test S-29-1 (integral test with asymmetrical break)

    International Nuclear Information System (INIS)

    Crapo, H.S.; Jensen, M.F.; Sackett, K.E.

    1976-07-01

    Recorded test data are presented for Test S-29-1 of the Semiscale Mod-1 special heat transfer test series. This test is among several Semiscale Mod-1 experiments conducted to investigate the thermal and hydraulic phenomena accompanying a hypothesized loss-of-coolant accident (LOCA) in a pressurized-water reactor system. Test S-29-1 was conducted from an initial cold leg fluid temperature of 544 0 F and an initial pressure of 2,260 psia. An asymmetrical offset shear cold leg break was used to investigate the system response to a depressurization transient with a flow distribution different from that associated with a symmetrical cold leg break. System flow was set to achieve a core fluid temperature differential of 66 0 F at full core power of 1.6 MW. The flow resistance of the intact loop was based on core area scaling. An electrically heated core with a flat radial power profile was used in the pressure vessel to simulate the effects of a nuclear core. During system depressurization, core power was reduced from the initial level of 1.6 MW to simulate the surface heat flux response of nuclear fuel rods until such time that departure from nucleate boiling (DNB) might occur. Blowdown to the pressure suppression system was accompanied by simulated emergency core cooling injection into both the intact and broken loops. Coolant injection was continued until test termination at 200 seconds after initiation of blowdown

  8. Natural cold baryogenesis from strongly interacting electroweak symmetry breaking

    International Nuclear Information System (INIS)

    Konstandin, Thomas; Servant, Géraldine

    2011-01-01

    The mechanism of ''cold electroweak baryogenesis'' has been so far unpopular because its proposal has relied on the ad-hoc assumption of a period of hybrid inflation at the electroweak scale with the Higgs acting as the waterfall field. We argue here that cold baryogenesis can be naturally realized without the need to introduce any slow-roll potential. Our point is that composite Higgs models where electroweak symmetry breaking arises via a strongly first-order phase transition provide a well-motivated framework for cold baryogenesis. In this case, reheating proceeds by bubble collisions and we argue that this can induce changes in Chern-Simons number, which in the presence of new sources of CP violation commonly lead to baryogenesis. We illustrate this mechanism using as a source of CP violation an effective dimension-six operator which is free from EDM constraints, another advantage of cold baryogenesis compared to the standard theory of electroweak baryogenesis. Our results are general as they do not rely on any particular UV completion but only on a stage of supercooling ended by a first-order phase transition in the evolution of the universe, which can be natural if there is nearly conformal dynamics at the TeV scale. Besides, baryon-number violation originates from the Standard Model only

  9. Comparisons of TRAC-PD2 calculations with Semiscale Mod-3 small-break tests

    International Nuclear Information System (INIS)

    Gilbert, J.S.; Sahota, M.S.; Boyack, B.E.; Booker, C.P.; Meier, J.K.

    1981-01-01

    Five experiments conducted in the Semiscale Mod-3 facility at the Idaho National Engineering Laboratory (INEL) were calculated using the latest released version of the Transient Reactor Analysis Code (TRAC-PD2). The results were used to assess TRAC-PD2 predictions of thermal-hydraulic phenomena and the effects of pump operation on system response during slow transients. Tests S-SB-P1, S-SB-P2, and S-SB-P7 simulated equivalent 2.5% communicative cold-leg breaks for early pump-trip (pumps-off), intermediate pump-trip (pumps-on), and late pump-trip (pumps-on) operation, respectively. Tests S-SB-P3 and S-SB-P4 simulated equivalent 2.5% communicative hot-leg breaks for pumps-off and pumps-on operation, respectively. Parameters examined in the study included primary system mass distribution, mass inventory, and void fraction distribution

  10. LOFT/LP-SB-2, Loss of Fluid Test, Small Hot Leg Break LOCA, Delayed Pump

    International Nuclear Information System (INIS)

    1989-01-01

    1 - Description of test facility: The LOFT Integral Test Facility is a scale model of a LPWR. The intent of the facility is to model the nuclear, thermal-hydraulic phenomena which would take place in a LPWR during a LOCA. The general philosophy in scaling coolant volumes and flow areas in LOFT was to use the ratio of the LOFT core [50 MW(t)] to a typical LPWR core [3000 MW(t)]. For some components, this factor is not applied; however, it is used as extensively as practical. In general, components used in LOFT are similar in design to those of a LPWR. Because of scaling and component design, the LOFT LOCA is expected to closely model a LPWR LOCA. 2 - Description of test: The third OECD LOFT experiment was conducted on 14 July 1983. It simulated a 3-in (7.62 cm) equivalent break diameter located in the hot leg of the operating loop. The major objective of this experiment was to determine system transient characteristics for small hot leg break loss-of-coolant accidents with delayed pump trip. The experiment was conducted from initial temperature and pressure conditions representative of typical commercial PWRs. 3 - Experimental limitations or shortcomings: Short core and steam generator, excessive core bypass, other scaling compromises, and lack of adequate measurements in certain areas

  11. LOFT/LP-SB-1, Loss of Fluid Test, Small Hot Leg Break LOCA, Early Pump

    International Nuclear Information System (INIS)

    1989-01-01

    1 - Description of test facility: The LOFT Integral Test Facility is a scale model of a LPWR. The intent of the facility is to model the nuclear, thermal-hydraulic phenomena which would take place in a LPWR during a LOCA. The general philosophy in scaling coolant volumes and flow areas in LOFT was to use the ratio of the LOFT core [50 MW(t)] to a typical LPWR core [3000 MW(t)]. For some components, this factor is not applied; however, it is used as extensively as practical. In general, components used in LOFT are similar in design to those of a LPWR. Because of scaling and component design, the LOFT LOCA is expected to closely model a LPWR LOCA. 2 - Description of test: The second OECD LOFT experiment was conducted on 23 June 1983. It simulated a 3-in (7.62 cm) equivalent break diameter located in the hot leg of the operating loop. The major objective of this experiment was to determine system transient characteristics for small hot leg break loss-of-coolant accidents with early pump trip. The experiment was conducted from initial temperature and pressure conditions representative of typical commercial PWRs. 3 - Experimental limitations or shortcomings: Short core and steam generator, excessive core bypass, other scaling compromises, and lack of adequate measurements in certain areas

  12. Natural cold baryogenesis from strongly interacting electroweak symmetry breaking

    Energy Technology Data Exchange (ETDEWEB)

    Konstandin, Thomas; Servant, Géraldine, E-mail: tkonstan@cern.ch, E-mail: geraldine.servant@cern.ch [CERN Physics Department, Theory Division, CH-1211 Geneva 23 (Switzerland)

    2011-07-01

    The mechanism of ''cold electroweak baryogenesis'' has been so far unpopular because its proposal has relied on the ad-hoc assumption of a period of hybrid inflation at the electroweak scale with the Higgs acting as the waterfall field. We argue here that cold baryogenesis can be naturally realized without the need to introduce any slow-roll potential. Our point is that composite Higgs models where electroweak symmetry breaking arises via a strongly first-order phase transition provide a well-motivated framework for cold baryogenesis. In this case, reheating proceeds by bubble collisions and we argue that this can induce changes in Chern-Simons number, which in the presence of new sources of CP violation commonly lead to baryogenesis. We illustrate this mechanism using as a source of CP violation an effective dimension-six operator which is free from EDM constraints, another advantage of cold baryogenesis compared to the standard theory of electroweak baryogenesis. Our results are general as they do not rely on any particular UV completion but only on a stage of supercooling ended by a first-order phase transition in the evolution of the universe, which can be natural if there is nearly conformal dynamics at the TeV scale. Besides, baryon-number violation originates from the Standard Model only.

  13. Investigating temperature breaks in the summer fruit export cold chain: A case study

    Directory of Open Access Journals (Sweden)

    Heinri W. Freiboth

    2013-11-01

    Full Text Available There is concern in the South African fruit industry that a large amount of fruit and money is lost every season due to breaks in the fruit export cold chain. The possibility of a large percentage of losses in a significant sector of the economy warranted further investigation. This article attempted to highlight some of the possible problem areas in the cold chain, from the cold store to the port, by analysing historic temperature data from different fruit export supply chains of apples, pears and grapes. In addition, a trial shipment of apples was used to investigate temperature variation between different pallets in the same container. This research has added value to the South African fruit industry by identifying the need to improve operational procedures in the cold chain.

  14. Investigating temperature breaks in the summer fruit export cold chain - a case study

    CSIR Research Space (South Africa)

    Freiboth, HW

    2013-11-01

    Full Text Available There is concern in the South African fruit industry that a large amount of fruit and money is lost every season due to breaks in the fruit export cold chain. The possibility of a large percentage of losses in a significant sector of the economy...

  15. RELAP5/SCDAPSIM model development for AP1000 and verification for large break LOCA

    Energy Technology Data Exchange (ETDEWEB)

    Trivedi, A.K. [Nuclear Engineering and Technology Program, Indian Institute of Technology, Kanpur 208016 (India); Allison, C. [Innovative Systems Software, Idaho Falls, ID 83406 (United States); Khanna, A., E-mail: akhanna@iitk.ac.in [Nuclear Engineering and Technology Program, Indian Institute of Technology, Kanpur 208016 (India); Munshi, P. [Nuclear Engineering and Technology Program, Indian Institute of Technology, Kanpur 208016 (India)

    2016-08-15

    Highlights: • RELAP5/SCDAPSIM model of AP1000 has been developed. • Analysis involves a LBLOCA (double ended guillotine break) study in cold leg. • Results are compared with those of WCOBRA–TRAC and TRACE. • Concluded that PCT does not violate the safety criteria of 1477 K. - Abstract: The AP1000 is a Westinghouse 2-loop pressurized water reactor (PWR) with all emergency core cooling systems based on natural circulation. Its core design is very similar to a 3-loop PWR with 157 fuel assemblies. Westinghouse has reported their results of the safety analysis in its design control document (DCD) for a large break loss of coolant accident (LOCA) using WCOBRA/TRAC and for a small break LOCA using NOTRUMP. The current study involves the development of a representative RELAP5/SCDASIM model for AP1000 based on publically available data and its verification for a double ended cold leg (DECL) break in one of the cold legs in the loop containing core makeup tanks (CMT). The calculated RELAP5/SCDAPSIM results have been compared to publically available WCOBRA–TRAC and TRACE results of DECL break in AP1000. The objective of this study is to benchmark thermal hydraulic model for later severe accident analyses using the 2D SCDAP fuel rod component in place of the RELAP5 heat structures which currently represent the fuel rods. Results from this comparison provides sufficient confidence in the model which will be used for further studies such as a station blackout. The primary circuit pumps, pressurizer and steam generators (including the necessary secondary side) are modeled using RELAP5 components following all the necessary recommendations for nodalization. The core has been divided into 6 radial rings and 10 axial nodes. For the RELAP5 thermal hydraulic calculation, the six groups of fuel assemblies have been modeled as pipe components with equivalent flow areas. The fuel including the gap and cladding is modeled as a 1d heat structure. The final input deck achieved

  16. RELAP5 simulation of a large break Loss of Coolant Accident (LOCA) in the hot leg of the primary system in Angra 2 nuclear power plant

    International Nuclear Information System (INIS)

    Andrade, Delvonei Alves de; Sabundjian, Gaiane

    2004-01-01

    The objective of this work is to present the simulation of a large break loss of coolant accident - LBLOCA in the hot leg of the primary loop in Angra 2, with RELAP5/MOD3.2.2g code. This accident is described in the Final Safety Report Analysis of Angra 2 - FSAR and consists basically of the hot leg total break, in loop 20 of the plant. The area considered for the rupture is 4480 cm 2 , which corresponds to 100% of the pipe flow area. Besides, this work also has the objective of verifying the efficiency of the emergency core coolant system - ECCS in case of accidents and transients. The thermal-hydraulic processes inherent to the accident phenomenology, such as hot leg vaporization and consequently core vaporization causing an inappropriate flow distribution in the reactor core, can lead to a reduction in the liquid level, until the ECCS is capable to reflood it

  17. OECD-LOFT large break LOCA experiments: phenomenology and computer code analyses

    International Nuclear Information System (INIS)

    Brittain, I.; Aksan, S.N.

    1990-08-01

    Large break LOCA data from LOFT are a very important part of the world database. This paper describes the two double-ended cold leg break tests LP-02-6 and LP-LB-1 carried out within the OECD-LOFT Programme. Tests in LOFT were the first to show the importance of both bottom-up and top-down quenching during blowdown in removing stored energy from the fuel. These phenomena are discussed in detail, together with the related topics of the thermal performance of nuclear fuel and its simulation by electric fuel rod simulators, and the accuracy of cladding external thermocouples. The LOFT data are particularly important in the validation of integral thermal-hydraulics codes such as TRAC and RELAP5. Several OECD partner countries contributed analyses of the large break tests. Results of these analyses are summarised and some conclusions drawn. 32 figs., 3 tabs., 45 refs

  18. Evaluation of the effects of break nozzle configuration in the Semiscale Mod-1 system

    International Nuclear Information System (INIS)

    Hanson, R.G.

    1977-08-01

    The Semiscale Mod-1 Program has utilized two different break nozzle configurations in the test system. An evaluation has been made to determine the effect these break nozzle configurations have on system thermal-hydraulic response during a 200 percent double-ended cold leg break loss-of-coolant accident simulation. The first nozzle was a convergent-divergent nozzle (Henry nozzle) and the second, an elongated constant area throat nozzle. Analysis is confined primarily to system response phenomena observed to be affected by the nozzle configuration and concentrates on the fluid response at the break and the resulting core behavior during subcooled and saturated blowdown. The evaluation shows that considerable difference in system response occurs as a result of the difference in break nozzle configuration. The elongated throat nozzle was scaled from the Loss-of-Fluid Test (LOFT) nozzle geometry and since the LOFT counterpart tests were designed to provide results for the LOFT Program, the elongated throat nozzle was used in the subsequent LOFT counterpart tests

  19. Packhouse to port: Investigating temperature breaks in the South African summer fruit export cold chain

    CSIR Research Space (South Africa)

    Freiboth, H

    2014-10-01

    Full Text Available A large amount of fruit and money is lost every season due to breaks in the South African fruit export cold chain. With food security becoming an ever growing concern, especially in developing countries like South Africa, a high percentage of losses...

  20. Assessment of RELAP/MOD2 using large break loss-of-coolant experimental data

    International Nuclear Information System (INIS)

    Kao, L.; Liao, L.Y.; Liang, K.S.; Wang, S.F.; Chen, Y.B.

    1989-01-01

    In this paper assessment of RELAP5/MOD2 using LOFT L2-5 and Semiscale S-06-3 tests are performed to provide information of the code capability and its limitation in analyzing large break LOCA of a nuclear power plant. Experiments L2-5 and S-06-3 are conducted to simulate a hypothetical LOCA which results from a 200% double-ended offset shear break in the cold-leg of a typical pressurized water reactor by utilizing scaling facilities of the LOFT and Semiscale Mod-1 systems, respectively. The RELAP5/MOD2 calculations for both tests begin with break initiation and subsequent blowdown, continue through lower plenum refill, core reflood, and terminate with corewide quench. Major phenomena of both large break loss-of-coolant tests are well predicted by RELAP5/MOD2. The results indicate that the break flow and system pressure are reasonably calculated. The cladding temperature response during blowdown period, which is the major importance to a large break LOCA, calculated by RELAP5/MOD2 shows good agreement with the test data

  1. Updated pipe break analysis for Advanced Neutron Source Reactor conceptual design

    International Nuclear Information System (INIS)

    Wendel, M.W.; Chen, N.C.J.; Yoder, G.L.

    1994-01-01

    The Advanced Neutron Source Reactor (ANSR) is a research reactor to be built at the Oak Ridge National Laboratory that will supply the highest continuous neutron flux levels of any reactor in the world. It uses plate-type fuel with high-mass-flux and highly subcooled heavy water as the primary coolant. The Conceptual Safety Analysis for the ANSR was completed in June 1992. The thermal-hydraulic pipe-break safety analysis (performed with a specialized version of RELAP5/MOD3) focused primarily on double-ended guillotine breaks of the primary piping and some core-damage mitigation options for such an event. Smaller, instantaneous pipe breaks in the cold- and hot-leg piping were also analyzed to a limited extent. Since the initial analysis for the conceptual design was completed, several important changes to the RELAP5 input model have been made reflecting improvements in the fuel grading and changes in the elevation of the primary coolant pumps. Also, a new philosophy for pipe-break safety analysis (similar to that adopted for the New Production Reactor) accentuates instantaneous, limited flow area pipe-break accidents in addition to finite-opening-time, double-ended guillotine breaks of the major coolant piping. This paper discloses the results of the most recent instantaneous pipe-break calculations

  2. Arm to leg coordination in elite butterfly swimmers.

    Science.gov (United States)

    Chollet, D; Seifert, L; Boulesteix, L; Carter, M

    2006-04-01

    This study proposed the use of four time gaps to assess arm-to-leg coordination in the butterfly stroke at increasing race paces. Fourteen elite male swimmers swam at four velocities corresponding to the appropriate paces for, respectively, the 400-m, 200-m, 100-m, and 50-m events. The different stroke phases of the arm and leg were identified by video analysis and then used to calculate four time gaps (T1: time gap between entry of the hands in the water and the high break-even point of the first undulation; T2: time gap between the beginning of the hands' backward movement and the low break-even point of the first undulation; T3: time gap between the hands' arrival in a vertical plane to the shoulders and the high break-even point of the second undulation; T4: time gap between the hands' release from the water and the low break-even point of the second undulation), the values of which described the changing relationship of arm to leg movements over an entire stroke cycle. With increases in pace, elite swimmers increased the stroke rate, the relative duration of the arm pull, the recovery and the first downward movement of the legs, and decreased the stroke length, the relative duration of the arm catch phase and the body glide with arms forward (measured by T2), until continuity in the propulsive actions was achieved. Whatever the paces, the T1, T3, and T4 values were close to zero and revealed a high degree of synchronisation at key motor points of the arm and leg actions. This new method to assess butterfly coordination could facilitate learning and coaching by situating the place of the leg undulation in relation with the arm stroke.

  3. Investigation of small break loss-of-coolant phenomena in a small scale nonnuclear test facility

    International Nuclear Information System (INIS)

    Cozzuol, J.M.; Fauble, T.J.; Harvego, E.A.

    1980-01-01

    A small-scale nonnuclear integral test facility designed to simulate a pressurized water reactor (PWR) system was used to evaluate the effects of a small break loss-of-coolant accident (LOCA) on the system thermal-hydraulic response. The experiment approximated a 2.5% (11-cm diameter) communicative break in the cold leg of a PWR, and included initial conditions which were similar to conditions in a PWR operating at full power. The 2.5% break size ensured that the nominal break flow rate was greater than the high pressure injection system (HPIS) flow rate, thus providing the potential for a continuous system depressurization. The sequence of events was similar to that used in evaluation model analysis of small break loss-of-coolant accidents, and included simulated reactor scram and loss of offsite power. Comparisions of experimental data with computer code calculations are used to demonstrate the capabilities and limitations of integral system calculations used to predict phenomena which can be important in the assessment of a small break LOCA in a PWR

  4. Don't break a leg: running birds from quail to ostrich prioritise leg safety and economy on uneven terrain.

    Science.gov (United States)

    Birn-Jeffery, Aleksandra V; Hubicki, Christian M; Blum, Yvonne; Renjewski, Daniel; Hurst, Jonathan W; Daley, Monica A

    2014-11-01

    Cursorial ground birds are paragons of bipedal running that span a 500-fold mass range from quail to ostrich. Here we investigate the task-level control priorities of cursorial birds by analysing how they negotiate single-step obstacles that create a conflict between body stability (attenuating deviations in body motion) and consistent leg force-length dynamics (for economy and leg safety). We also test the hypothesis that control priorities shift between body stability and leg safety with increasing body size, reflecting use of active control to overcome size-related challenges. Weight-support demands lead to a shift towards straighter legs and stiffer steady gait with increasing body size, but it remains unknown whether non-steady locomotor priorities diverge with size. We found that all measured species used a consistent obstacle negotiation strategy, involving unsteady body dynamics to minimise fluctuations in leg posture and loading across multiple steps, not directly prioritising body stability. Peak leg forces remained remarkably consistent across obstacle terrain, within 0.35 body weights of level running for obstacle heights from 0.1 to 0.5 times leg length. All species used similar stance leg actuation patterns, involving asymmetric force-length trajectories and posture-dependent actuation to add or remove energy depending on landing conditions. We present a simple stance leg model that explains key features of avian bipedal locomotion, and suggests economy as a key priority on both level and uneven terrain. We suggest that running ground birds target the closely coupled priorities of economy and leg safety as the direct imperatives of control, with adequate stability achieved through appropriately tuned intrinsic dynamics. © 2014. Published by The Company of Biologists Ltd.

  5. Analysis of a hot-leg small break loss-of-coolant accident in a three-loop westinghouse pressurized water reactor plant

    International Nuclear Information System (INIS)

    Peterson, C.E.; Chexal, V.K.; Clements, T.B.

    1985-01-01

    The RETRAN-02 computer code was used to perform a best-estimate analysis of a 7.52-cm-diam hotleg break in a three-loop Westinghouse pressurized water reactor. This break size produced a net primary coolant mass depletion through the early portion of the transient. The primary system started to refill only after the accumulator valves opened. As the primary system refilled, there were extreme temperature differentials around the system with cold, denser fluid collecting at the lower elevations and two-phase fluid at higher elevations

  6. Evaluation of ATLAS 100% DVI Line Break Using TRACE Code

    International Nuclear Information System (INIS)

    Huh, Byung Gil; Bang, Young Seok; Cheong, Ae Ju; Woo, Sweng Woong

    2011-01-01

    ATLAS (Advanced Thermal-Hydraulic Test Loop for Accident Simulation) is an integral effect test facility in KAERI. It had installed completely to simulate the accident for the OPR1000 and the APR1400 in 2005. After then, several tests for LBLOCA, DVI line break have been performed successfully to resolve the safety issues of the APR1400. Especially, a DVI line break is considered as another spectrum among the SBLOCAs in APR1400 because the DVI line is directly connected to the reactor vessel and the thermal hydraulic behaviors are expected to be different from those for the cold leg injection. However, there are not enough experimental data for the DVI line break. Therefore, integral effect data for the DVI line break of ATLAS is very useful and available for an improvement and validation of safety codes. For the DVI line break in ATLAS, several analyses using MARS and RELAP codes were performed in the ATLAS DSP (Domestic Standard Problem) meetings. However, TRACE code has still not used to simulate a DVI line break. TRACE code has developed as the unified code for the reactor thermal hydraulic analyses in USNRC. In this study, the 100% DVI line break in ATLAS was evaluated by TRACE code. The objectives of this study are to identify the prediction capability of TRACE code for the major thermal hydraulic phenomena of a DVI line break in ATLAS

  7. Simulation of a severe accident at a typical PWR due to break of a hot leg ECCS line using MELCOR code

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Seung Min; Sabundjian, Gaianê, E-mail: smlee@ipen.br, E-mail: gdjian@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2017-11-01

    The aim of this work was to simulate a severe accident at a typical PWR caused by break in Emergency Core Cooling System (ECCS) line of a hot leg using the MELCOR code. The nodalization of this typical PWR was elaborated by the Global Research for Safety (GRS) and provided to the CNEN for analysis of the severe accidents at the Angra 2, which is similar to that PWR. Although both of them are not identical the results obtained for that typical PWR may be valuable because of the lack of officially published calculation for Angra 2. Relevant parameters such as pressure, temperature and water level in various control volumes after the break in the hot leg were calculated as well as degree of core degradation and hydrogen concentration in containment. The result obtained in this work could be considered satisfactory in the sense that the physical phenomena reproduced by the simulation were in general very reasonable, and most of the events occurred within acceptable time intervals. However, the uncertainty analysis was not carried out in this work. Furthermore, this scenario could be used as a base for the study of the effectiveness of some preventive or/and mitigating measures of Severe Accident Management (SAMG) by adding associated conditions for each measure in its input. (author)

  8. Simulation of a severe accident at a typical PWR due to break of a hot leg ECCS line using MELCOR code

    International Nuclear Information System (INIS)

    Lee, Seung Min; Sabundjian, Gaianê

    2017-01-01

    The aim of this work was to simulate a severe accident at a typical PWR caused by break in Emergency Core Cooling System (ECCS) line of a hot leg using the MELCOR code. The nodalization of this typical PWR was elaborated by the Global Research for Safety (GRS) and provided to the CNEN for analysis of the severe accidents at the Angra 2, which is similar to that PWR. Although both of them are not identical the results obtained for that typical PWR may be valuable because of the lack of officially published calculation for Angra 2. Relevant parameters such as pressure, temperature and water level in various control volumes after the break in the hot leg were calculated as well as degree of core degradation and hydrogen concentration in containment. The result obtained in this work could be considered satisfactory in the sense that the physical phenomena reproduced by the simulation were in general very reasonable, and most of the events occurred within acceptable time intervals. However, the uncertainty analysis was not carried out in this work. Furthermore, this scenario could be used as a base for the study of the effectiveness of some preventive or/and mitigating measures of Severe Accident Management (SAMG) by adding associated conditions for each measure in its input. (author)

  9. Numerical modelling of the processes in the WWER-1000 containment building during cold leg LOCA using the CONTEMPT-LT/026 code

    International Nuclear Information System (INIS)

    Kolev, N.I.; Sybotinov, L.S.

    1984-01-01

    The CONTEMPT-LT/026 code has been used to produce numerical results for the processes in a WWER-1000 containment building during cold leg LOCA with break at the reactor vessel. The objective of the analysis is to estimate the maximal loads on the containment in case of LOCA. Available design data for the geometry and for the operational characteristics of the low-pressure ECC system and the sprinkler system have been used. Boundary conditions such as mass flow and enthalpies at the breach are given by a RELAP4/MOD6 computation. Hydrogen explosions in the containment are not considered. It is found that in case of normal functioning of the low-pressure ECC system the maximal pressure is 3,26±0,44 bar. In the case of malfunctioning of the low-pressure ECC system, the predicted maximal pressure is 4±0,44 bar, when: a) only 50% of the heat transfer surface of the heat exchanger is effectively used due to pollution; b) the main pipeline of the sprinkler is broken; c) the pipeline to the heat exchanger is partially broken so that the mass flow through the exchanger is only 50% of the nominal; and d) ECC low-pressure ECC system attains its maximal efficiency within 3 min, the predicted maximal pressure is 4±0,44 bar

  10. Sampling based uncertainty analysis of 10% hot leg break LOCA in large scale test facility

    International Nuclear Information System (INIS)

    Sengupta, Samiran; Kraina, V.; Dubey, S. K.; Rao, R. S.; Gupta, S. K.

    2010-01-01

    Sampling based uncertainty analysis was carried out to quantify uncertainty in predictions of best estimate code RELAP5/MOD3.2 for a thermal hydraulic test (10% hot leg break LOCA) performed in the Large Scale Test Facility (LSTF) as a part of an IAEA coordinated research project. The nodalisation of the test facility was qualified for both steady state and transient level by systematically applying the procedures led by uncertainty methodology based on accuracy extrapolation (UMAE); uncertainty analysis was carried out using the Latin hypercube sampling (LHS) method to evaluate uncertainty for ten input parameters. Sixteen output parameters were selected for uncertainty evaluation and uncertainty band between 5 th and 95 th percentile of the output parameters were evaluated. It was observed that the uncertainty band for the primary pressure during two phase blowdown is larger than that of the remaining period. Similarly, a larger uncertainty band is observed relating to accumulator injection flow during reflood phase. Importance analysis was also carried out and standard rank regression coefficients were computed to quantify the effect of each individual input parameter on output parameters. It was observed that the break discharge coefficient is the most important uncertain parameter relating to the prediction of all the primary side parameters and that the steam generator (SG) relief pressure setting is the most important parameter in predicting the SG secondary pressure

  11. Data report of ROSA/LSTF experiment SB-HL-12. 1% hot leg break LOCA with SG depressurization and gas inflow

    International Nuclear Information System (INIS)

    Takeda, Takeshi

    2016-01-01

    An experiment SB-HL-12 was conducted on February 24, 1998 using the Large Scale Test Facility (LSTF) in the Rig of Safety Assessment-V (ROSA-V) Program. The ROSA/LSTF experiment SB-HL-12 simulated a 1% hot leg small-break loss-of-coolant accident in a pressurized water reactor under assumptions of total failure of high pressure injection system and non-condensable gas (nitrogen gas) inflow to the primary system from accumulator (ACC) tanks of emergency core cooling system (ECCS). Steam generator (SG) secondary-side depressurization by fully opening the relief valves in both SGs as an accident management (AM) action was initiated immediately after maximum surface temperature of simulated fuel rod reached 600 K. Auxiliary feedwater injection into the secondary-side of both SGs was started immediately after the initiation of AM action. After the onset of AM action due to first core uncovery by core boil-off, the primary pressure decreased following the SG secondary-side pressure, causing core mixture level swell. The fuel rod surface temperature then increased up to 635 K. Second core uncovery by core boil-off took place before loop seal clearing (LSC) induced by steam condensation on ACC coolant injected into cold legs. The core liquid level recovered rapidly after the LSC. The fuel rod surface temperature then increased up to 696 K. The pressure difference became larger between the primary and SG secondary sides after the ACC tanks started to discharge nitrogen gas, which resulted in no actuation of LPI system of ECCS during the experiment. Third core uncovery by core boil-off occurred during the reflux condensation in the SG U-tubes under nitrogen gas inflow. The core power was automatically decreased by the LSTF core protection system when the maximum fuel rod surface temperature exceeded 908 K. The obtained data would be useful to define the conditions for counterpart testing of other integral test facilities to address scaling problems through thermal

  12. Small break LOCA [loss of coolant accident] mitigation for Bellefonte

    International Nuclear Information System (INIS)

    Bayless, P.D.; Dobbe, C.A.

    1986-01-01

    Several 5-cm (2-in.) diameter cold leg break loss coolant accidents for the Bellefonte nuclear plant were analyzed as part of the Severe Accident Sequence Analysis Program. The transients assumed various system failures, and included the S 2 D sequence. Operator actions to mitigate the S 2 D transient were also investigated. The transients were analyzed until either core damage began or long-term decay heat removal was established. The S 2 D sequence was analyzed into the core damage phase of the transient. The analyses showed that the flow from one high pressure injection pump was necessary and sufficient to prevent core damage in the absence of operator actions. Operator actions were also able to prevent core damage for the S 2 D sequence

  13. BEACON/MOD2A analysis of the Arkansas-1 reactor cavity during a hypothetical hot leg break

    International Nuclear Information System (INIS)

    Ramsthaler, J.A.

    1979-01-01

    As part of the evaluation of the new MOD2A version of the BEACON code, the Arkansas-1 reactor cavity was modeled during a hypothetical loss-of-coolant accident. Results of the BEACON analysis were compared with results obtained previously with the COMPARE containment code. Studies were also made investigating some of the BEACON interphasic, timestep control, and wall heat transfer options to assure that these models were working properly and to observe their effects on the results. Descriptions of the Arkansas-1 reactor cavity, initial assumptions during the hypothetical LOCA, and methods of modeling with BEACON are presented. Some of the problems encountered in accurately modeling the penetrations surrounding the hot and cold leg pipes are also discussed

  14. Potential for boron dilution during small-break LOCAs in PWRs

    International Nuclear Information System (INIS)

    Nourbakhsh, H.P.; Cheng, Z.

    1995-01-01

    This paper documents the results of a scoping study of boron dilution and mixing phenomena during small break loss of coolant accidents (LOCAs) in pressurized water reactors (PWRs). Boron free condensate can accumulate in the cold leg loop seals when the reactor is operating in a reflux/boiler condenser mode. A problem may occur when the subsequent change in flow conditions such as loop seal clearing or re-establishment of natural circulation flow drive the diluted water in the loop seals into the reactor core without sufficient mixing with the highly borated water in the reactor downcomer and lower plenum. The resulting low boron concentration coolant entering the core may cause a power excursion leading to fuel failure. The mixing processes associated with a slow moving stream of diluted water through the loop seal to the core were examined in this report. A bounding evaluation of the range of boron concentration entering the core during a small break LOCA in a typical Westinghouse-designed, four-loop plant is also presented in this report

  15. Mixing phenomena of interest to boron dilution during small break LOCAs in PWRs

    International Nuclear Information System (INIS)

    Nourbakhsh, H.P.; Cheng, Z.

    1995-01-01

    This paper presents the results of a study of mixing phenomena related to boron dilution during small break loss of coolant accidents (LOCAs)in pressurized water reactors (PWRs). Boron free condensate can accumulate in the cold leg loop seals when the reactor is operating in a reflux/boiler-condenser mode. A problem may occur when subsequent change in flow conditions such as loop seal clearing or re-establishment of natural circulation flow drive the diluted water in the loop seals into the reactor core without sufficient mixing with the highly borated water in the reactor downcomer and lower plenum. The resulting low boron concentration coolant entering the core may cause a power excursion leading to fuel failure. The mixing processes associated with a slow moving stream of diluted water through the loop seal to the core are examined in this paper. Bounding calculations for boron concentration of coolant entering the core during a small break LOCA in a typical Westinghouse-designed four-loop plant are also presented

  16. Technical manual for COMET

    International Nuclear Information System (INIS)

    Song, Jin Ho; Kwon, Young Min; Kim, Taek Mo; Lee, Sang Jong; Jeong, Hae Yong

    1996-07-01

    The purpose of this report is to provide a description for a COMET computer code which is to be used in the analysis of mass and energy releases during post-blowdown phase of LOCA. The mass and energy data re to be used as input data for the containment functional design. This report contains a brief description of analytical models and guidelines for the usage of the computer code. This computer code is to be used for both cold leg and hot leg break analyses. A verification analyses are performed for Ulchin 3 and 4 cold and hot leg break. 11 figs (Author)

  17. Relationship of the Cold-Heat Sensation of the Limbs and Abdomen with Physiological Biomarkers.

    Science.gov (United States)

    Pham, Duong Duc; Lee, JeongHoon; Kim, GaYul; Song, JiYeon; Kim, JiEun; Leem, Chae Hun

    2016-01-01

    The present study explored the relationship between the regional Cold-Heat sensation, the key indicator of the Cold-Heat patterns in traditional East Asian medicine (TEAM), and various biomarkers in Korean population. 734 apparently healthy volunteers aged 20 years and older were enrolled. Three scale self-report questions on the general thermal feel in hands, legs, and abdomen were examined. We found that 65% of women tended to perceive their body, particularly their hands and legs, to be cold, versus 25% of men. Energy expenditure and temperature load at resting state were lower in women, independently of body mass index (BMI). Those with warm hands and warm legs had a 0.74 and 0.52 kg/m 2 higher BMI than those with cold hands and cold legs, respectively, regardless of age, gender, and body weight. Norepinephrine was higher, whereas the dynamic changes in glucose and insulin during an oral glucose tolerance test were lower in those with cold extremities, particularly hands. No consistent differences in biomarkers were found for the abdominal dimension. These results suggest that gender, BMI, the sympathetic nervous system, and glucose metabolism are potential determinants of the Cold-Heat sensation in the hands and legs, but not the abdomen.

  18. Relationship of the Cold-Heat Sensation of the Limbs and Abdomen with Physiological Biomarkers

    Directory of Open Access Journals (Sweden)

    Duong Duc Pham

    2016-01-01

    Full Text Available The present study explored the relationship between the regional Cold-Heat sensation, the key indicator of the Cold-Heat patterns in traditional East Asian medicine (TEAM, and various biomarkers in Korean population. 734 apparently healthy volunteers aged 20 years and older were enrolled. Three scale self-report questions on the general thermal feel in hands, legs, and abdomen were examined. We found that 65% of women tended to perceive their body, particularly their hands and legs, to be cold, versus 25% of men. Energy expenditure and temperature load at resting state were lower in women, independently of body mass index (BMI. Those with warm hands and warm legs had a 0.74 and 0.52 kg/m2 higher BMI than those with cold hands and cold legs, respectively, regardless of age, gender, and body weight. Norepinephrine was higher, whereas the dynamic changes in glucose and insulin during an oral glucose tolerance test were lower in those with cold extremities, particularly hands. No consistent differences in biomarkers were found for the abdominal dimension. These results suggest that gender, BMI, the sympathetic nervous system, and glucose metabolism are potential determinants of the Cold-Heat sensation in the hands and legs, but not the abdomen.

  19. Desensitization of menthol-activated cold receptors in lower extremities during local cooling in young women with a cold constitution.

    Science.gov (United States)

    Yamazaki, Fumio; Sone, Ryoko

    2017-03-01

    To test the hypothesis that topical menthol-induced reactivity of cold sensation and cutaneous vasoconstriction to local cooling is augmented in individuals with a cold constitution, we examined thermal sensation and cutaneous vasoconstrictor responses at menthol-treated and untreated sites in the legs during local skin cooling in young women complaining of chilliness (C group) and young women with no complaint as a normal control group (N group). During local skin cooling, the sensitivity to cold sensation was greater in the C group than in the N group. The application of menthol enhanced the cold sensation at a low temperature in the N group, but not in the C group. Cutaneous vasoconstrictor responses to local skin cooling were not altered by menthol treatment in either of the two groups. These findings suggest the desensitization of menthol-activated cold receptors in the legs of C group subjects, and a minor role of cold receptor activity in cutaneous vasoconstrictor response to local cooling.

  20. Reliability of CRBR primary piping: critique of stress-strength overlap method for cold-leg inlet downcomer

    International Nuclear Information System (INIS)

    Bari, R.A.; Buslik, A.J.; Papazoglou, I.A.

    1976-04-01

    A critique is presented of the strength-stress overlap method for the reliability of the CRBR primary heat transport system piping. The report addresses, in particular, the reliability assessment of WARD-D-0127 (Piping Integrity Status Report), which is part of the CRBR PSAR docket. It was found that the reliability assessment is extremely sensitive to the assumed shape for the probability density function for the strength (regarded as a random variable) of the cold-leg inlet downcomer section of the primary piping. Based on the rigorous Chebyschev inequality, it is shown that the piping failure probability is less than 10 -2 . On the other hand, it is shown that the failure probability can be much larger than approximately 10 -13 , the typical value put forth in WARD-D-0127

  1. Experiment data report for LOFT large-break loss-of-coolant experiment L2-5

    International Nuclear Information System (INIS)

    Bayless, P.D.; Divine, J.M.

    1982-08-01

    Selected pertinent and uninterpreted data from the third nuclear large break loss-of-coolant experiment (Experiment L2-5) conducted in the Loss-of-Fluid Test (LOFT) facility are presented. The LOFT facility is a 50-MW(t) pressurized water reactor (PWR) system with instruments that measure and provide data on the system thermal-hydraulic and nuclear conditions. The operation of the LOFT system is typical of large [approx. 1000 MW(e)] commercial PWR operations. Experiment L2-5 simulated a double-ended offset shear of a cold leg in the primary coolant system. The primary coolant pumps were tripped within 1 s after the break initiation, simulating a loss of site power. Consistent with the loss of power, the starting of the high- and low-pressure injection systems was delayed. The peak fuel rod cladding temperature achieved was 1078 +- 13 K. The emergency core cooling system re-covered the core and quenched the cladding. No evidence of core damage was detected

  2. LOFT/L3-, Loss of Fluid Test, 7. NRC L3 Small Break LOCA Experiment

    International Nuclear Information System (INIS)

    1992-01-01

    1 - Description of test facility: The LOFT Integral Test Facility is a scale model of a LPWR. The intent of the facility is to model the nuclear, thermal-hydraulic phenomena which would take place in a LPWR during a LOCA. The general philosophy in scaling coolant volumes and flow areas in LOFT was to use the ratio of the LOFT core [50 MW(t)] to a typical LPWR core [3000 MW(t)]. For some components, this factor is not applied; however, it is used as extensively as practical. In general, components used in LOFT are similar in design to those of a LPWR. Because of scaling and component design, the LOFT LOCA is expected to closely model a LPWR LOCA. 2 - Description of test: This was the seventh in the NRC L3 Series of small-break LOCA experiments. A 2.5-cm (10-in.) cold-leg non-communicative-break LOCA was simulated. The experiment was conducted on 20 June 1980

  3. Cold leg injection reflood test results in the SCTF Core-I under constant system pressure

    International Nuclear Information System (INIS)

    Adachi, Hiromichi; Iwamura, Takamichi; Sobajima, Makoto; Osakabe, Masahiro; Ohnuki, Akira; Abe, Yutaka; Murao, Yoshio.

    1990-08-01

    The Slab Core Test Facility (SCTF) was constructed to investigate two-dimensional thermal-hydrodynamics in the core and the interaction in fluid behavior between the core and the upper plenum during the last part of blowdown, refill and reflood phases of a postulated loss-of-coolant accident (LOCA) of a pressurized water reactor (PWR). The present report describes the analytical results on the system behavior observed in the SCTF Core-I cold leg injection tests, S1-14 (Run 520), S1-15 (521), S1-16 (522), S1-17 (523), S1-20 (530), S1-21 (531), S1-23 (536) and S1-24 (537), performed under constant system pressure condition during transient. Major discussion items are: (1) steam binding, (2) U-tube oscillations, (3) bypass of ECC water (4) core cooling behavior, (5) effect of vent valve and (6) other parameter effects. These results give us very useful information and suggestion on reflood behavior. (author)

  4. Analysis of small break loss of coolant accident for Chinese CPR1000

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Ju Youl [FNC Technology Co., Yongin (Korea, Republic of); Cilier, Anthonie [North-West University, Mahikeng (South Africa); Poc, Li-chi Cliff [Micro-Simulation Technology, Montville (United States)

    2016-05-15

    This research analyses the small break loss of coolant accident (LOCA) on a Chinese CPR1000 type reactor. LOCA accident is used as benchmark for the PCTRAN/CPR1000 code by comparing the effects and results to the Manshaan FSAR accident analysis. LOCA is a design basis accident in which a guillotine break is postulated to occur in one of the cold legs of a pressurized water reactor (PWR). Consequently, the primary system pressure would drop and almost all the reactor coolant would be discharged into the reactor containment. The drop in pressure would activate the reactor protection system and the reactor would trip. The simulation of a 3-inch small break loss of coolant accident using the PCTRAN/CPR1000 has revealed this code's effectiveness as well as weaknesses in specific simulation applications. The code has the ability to run at 16 times real time and produce very accurate results. The results are consistently producing the same trends as licensed codes used in Safety Assessment Reports. It is however able to produce these results in a fraction of the time and also provides a whole plant simulation coupling the various thermal, hydraulic, chemical and neutronic systems together with a plant specific control system.

  5. LOFT/L3-6, Loss of Fluid Test, 6. NRC L3 Small Break LOCA Experiment

    International Nuclear Information System (INIS)

    1992-01-01

    1 - Description of test facility: The LOFT Integral Test Facility is a scale model of a LPWR. The intent of the facility is to model the nuclear, thermal-hydraulic phenomena which would take place in a LPWR during a LOCA. The general philosophy in scaling coolant volumes and flow areas in LOFT was to use the ratio of the LOFT core [50 MW(t)] to a typical LPWR core [3000 MW(t)]. For some components, this factor is not applied; however, it is used as extensively as practical. In general, components used in LOFT are similar in design to those of a LPWR. Because of scaling and component design, the LOFT LOCA is expected to closely model a LPWR LOCA. 2 - Description of test: This was the sixth in the NRC L3 Series of small-break LOCA experiments. A 10-cm (2.5-in.) cold-leg non-communicative-break LOCA was simulated. Pumps were running. The experiment was conducted on 10 December 1980

  6. LOFT/L3-5, Loss of Fluid Test, 5. NRC L3 Small Break LOCA Experiment

    International Nuclear Information System (INIS)

    1991-01-01

    1 - Description of test facility: The LOFT Integral Test Facility is a scale model of a LPWR. The intent of the facility is to model the nuclear, thermal-hydraulic phenomena which would take place in a LPWR during a LOCA. The general philosophy in scaling coolant volumes and flow areas in LOFT was to use the ratio of the LOFT core [50 MW(t)] to a typical LPWR core [3000 MW(t)]. For some components, this factor is not applied; however, it is used as extensively as practical. In general, components used in LOFT are similar in design to those of a LPWR. Because of scaling and component design, the LOFT LOCA is expected to closely model a LPWR LOCA. 2 - Description of test: This was the fifth in the NRC L3 Series of small-break LOCA experiments. A 10-cm (2.5-in.) cold-leg non-communicative-break LOCA was simulated. Pumps were shut off. The experiment was conducted on 29 September 1980

  7. LOFT/L2-3, Loss of Fluid Test, 2. NRC L2 Large Break LOCA Experiment

    International Nuclear Information System (INIS)

    1992-01-01

    1 - Description of test facility: The LOFT Integral Test Facility is a scale model of a LPWR. The intent of the facility is to model the nuclear, thermal-hydraulic phenomena which would take place in a LPWR during a LOCA. The general philosophy in scaling coolant volumes and flow areas in LOFT was to use the ratio of the LOFT core [50 MW(t)] to a typical LPWR core [3000 MW(t)]. For some components, this factor is not applied; however, it is used as extensively as practical. In general, components used in LOFT are similar in design to those of a LPWR. Because of scaling and component design, the LOFT LOCA is expected to closely model a LPWR LOCA. 2 - Description of test: This experiment was the second of the NRC L2 Series of nuclear large Break LOCA experiments, and was conducted on 12 May 1979. It simulated a 100% cold leg break with a maximum heat generation of 39 kW/m

  8. A study of thermal stratification in the cold legs during the subcooled blowdown phase of a loss of coolant accident in the OSU APEX thermal hydraulic testing facility

    International Nuclear Information System (INIS)

    Wachs, D. M.

    1998-01-01

    Thermal stratification, which has been linked to the occurrence of pressurized thermal shock (PTS), is observed to occur during the early stages of simulated loss of coolant accidents (LOCAS) in the Oregon State University Advanced Plant Experiment (OSU APEX) Thermal Hydraulic Test Facility. The OSU APEX Test Facility is a scaled model of the Westinghouse AP600 nuclear power plant. Analysis of the OSU APEX facility data has allowed the determination of an onset criteria for thermal stratification and has provided support for the postulated mechanisms leading to thermal stratification. CFX 4.1, a computational fluid dynamics code, was used to generate a model of the cold legs and the downcomer that described the phenomena occurring within them. Some mixing phenomena were predicted that lead to non-uniformity between the two cold legs attached to the steam generator on the side of the facility containing the Passive Residual Heat Removal (PRHR) injection system. The stratification was found to be two phase and unlikely to be a factor in PTS

  9. The phenomenology of a small break LOCA in a complex thermal hydraulic loop

    International Nuclear Information System (INIS)

    Di Marzo, M.; Almenas, K.K.; Hsu, Y.Y.; Wang, Z.

    1988-01-01

    A phenomenological description of the thermal hydraulics events that take place during a simulated Small Break Loss of Coolant Accident (SB-LOCA) is presented. The SB-LOCA transient is described in detail and the various mass and energy transport modes are identified. Similar behavior is observed in other facilities designed for the simulation of this type of accidents. Previous investigations suggest a simple modelling of the phenomena based on fluid mechanic considerations. An extensive experimental program conducted at the experimental facility of the University of Maryland reveals that condensation is a dominant driving force for this type of transients. This finding has significant implications in the modelling of enthalpy transport for some of the flow modes which occur during the transient. In particular it affects the Interruption and Resumption Mode (IRM) during which enthalpy is transported by periodic flow of a two phase mixture. The efforts to predict the flow interruption based on fluid mechanic criteria of phase separation in the hot leg are shown to be misdirected since thermodynamic phenomena taking place in the horizontal portion of the cold legs and in the reactor vessel downcomer are mostly responsible for that transition. For flow resumption to occur the liquid-vapor mixture swelling in the vertical portion of the hot leg determines the occurrence of the liquid spill over the top of the candy cane. (orig.)

  10. Analysis, by Relap5 code, of boron dilution phenomena in a Small Break Loca Transient, performed in PKL III E 2.2 test

    International Nuclear Information System (INIS)

    Rizzo, G.; Vella, G.

    2007-01-01

    The present work is finalized to investigate the E2.2 thermal-hydraulics transient of the PKL III facility, which is a scaled reproduction of a typical German PWR, operated by FRAMATOME-ANP in Erlangen, Germany, within the framework of an international cooperation (OECD/SETH project). The main purpose of the project is to study boron dilution events in Pressurized Water Reactors and to contribute to the assessment of thermal-hydraulic system codes like Relap5. The experimental test PKL III E2.2 investigates the behavior of a typical PWR after a Small Break Loss Of Coolant Accident (SB-LOCA) in a cold leg and an immediate injection of borated water in two cold legs. The main purpose of this work is to simulate the PKL III test facility and particularly its experimental transient by Relap5 system code. The adopted nodalization, already available at Department of Nuclear Engineering (DIN), has been reviewed and applied with an accurate analysis of the experimental test parameters. The main result relies in a good agreement of calculated data with experimental measures for a number of main important variables. (author)

  11. Thermal-Hydraulic Integral Effect Test with ATLAS for an Intermediate Break Loss of Coolant Accident at a Pressurizer Surge Line

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Kyoung Ho; Seok Cho; Park, Hyun Sik; Choi, Nam Hyun; Park, Yu Sun; Kim, Jong Rok; Bae, Byoung Uhn; Kim, Yeon Sik; Kim, Kyung Doo; Choi, Ki Yong; Song, Chul Hwa [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2013-10-15

    The main objectives of this test were not only to provide physical insight into the system response of the APR1400 during the pressurizer surge line break accident but also to produce an integral effect test data to validate the SPACE code. In order to simulate a double-ended guillotine break of a pressurizer surge line in the APR1400, the IB-SUR-01R test was performed with ATLAS. The major thermal-hydraulic phenomena such as the system pressures, the collapsed water levels, and the break flow rate were presented and discussed. Despite the core was uncovered, no excursion in the cladding temperature was observed. The pressurizer surge line break can be classified as a hot leg break from a break location point of view. Compared with a cold leg break, coolability in the core may be better in case of a hot leg break due to the enhanced flow in the core region. This integral effect test data will be used to evaluate the prediction capability of existing safety analysis codes of the MARS and the RELAP5 as well as the SPACE code. Furthermore, this data can be utilized to identify any code deficiency for an IBLOCA simulation, especially for DVI-adapted plants. Redefinition of break size for design basis accident (DBA) based on risk information is being extensively investigated due to the potential for safety benefits and unnecessary burden reduction from current LBLOCA (large break loss of coolant accident)-based ECC (Emergency Core Cooling) Acceptance Criteria. As a transition break size (TBS), the rupture of medium-size pipe is considered to be more important than ever in risk-informed regulation (RIR)-relevant safety analysis. As plants age, are up-rated, and continue to seek improved operating efficiencies, the small break and intermediate break LOCA (IBLOCA) can become a concern. In particular, IBLOCA with DVI (Direct Vessel Injection) features will be addressed to support redefinition of a design-basis LOCA. With an aim of expanding code validation to address small

  12. The comparison of cold-water immersion and cold air therapy on maximal cycling performance and recovery markers following strength exercises

    Directory of Open Access Journals (Sweden)

    Kane J. Hayter

    2016-03-01

    Full Text Available This study examined the effects of cold-water immersion (CWI and cold air therapy (CAT on maximal cycling performance (i.e. anaerobic power and markers of muscle damage following a strength training session. Twenty endurance-trained but strength-untrained male (n = 10 and female (n = 10 participants were randomised into either: CWI (15 min in 14 °C water to iliac crest or CAT (15 min in 14 °C air immediately following strength training (i.e. 3 sets of leg press, leg extensions and leg curls at 6 repetition maximum, respectively. Creatine kinase, muscle soreness and fatigue, isometric knee extensor and flexor torque and cycling anaerobic power were measured prior to, immediately after and at 24 (T24, 48 (T48 and 72 (T72 h post-strength exercises. No significant differences were found between treatments for any of the measured variables (p > 0.05. However, trends suggested recovery was greater in CWI than CAT for cycling anaerobic power at T24 (10% ± 2%, ES = 0.90, T48 (8% ± 2%, ES = 0.64 and T72 (8% ± 7%, ES = 0.76. The findings suggest the combination of hydrostatic pressure and cold temperature may be favourable for recovery from strength training rather than cold temperature alone.

  13. Intermediate Leg SBLOCA - Long Lasting Pressure Transient

    International Nuclear Information System (INIS)

    Konjarek, D.; Bajs, T.; Vukovic, J.

    2010-01-01

    The basic phenomenology of Small Break Loss of Coolant Accident (SBLOCA) for PWR plant is described with focus on analysis of scenario in which reactor coolant pressure decreases below secondary system pressure. Best estimate light water reactor transient analysis code RELAP5/mod3.3 was used in calculation. Rather detailed model of the plant was used. The break occurs in intermediate leg on lowest elevation near pump suction. The size of the break is chosen to be small enough to cause cycling of safety valves (SVs) on steam generators (SGs) for some time, but, afterwards, it is large enough to remove decay heat through the break, causing cooling the secondary side. In this case of SBLOCA, when primary pressure decreases below secondary pressure, long lasting pressure transients with significant amplitude occur. Reasons for such behavior are explained.(author).

  14. 2D/3D program. Upper plenum test facility - UPTF. Test No. 1

    International Nuclear Information System (INIS)

    1987-01-01

    Test No.1 was a quasi-steady state, separate effect test involving the UPTF-System with blocked break valves and blocked pump simulators. Initially the test vessel, the cold and hot leg nozzels as well as the pump seals were completely filled witht hot water in this test. This test was designed to investigate the fluid-fluid mixing phenomena and the development of the fluid and wall temperature fields in the cold leg and downcomer region of a PWR. The experiment was performed by injecting a cold water stream into one cold leg of UPTF while the system was initially filled with stagnant hot water. (orig.)

  15. Condensation during gravity driven ECC: Experiments with PACTEL

    Energy Technology Data Exchange (ETDEWEB)

    Munther, R.; Kalli, H. [Lappeenranta Univ. of Technology (Finland); Kouhia, J. [Technical Research Centre of Finland, Lappeenranta (Finland)

    1995-09-01

    This paper provides the results of the second series of gravity driven emergency core cooling (ECC) experiments with PACTEL (Parallel Channel Test Loop). The simulated accident was a small break loss-of-coolant accident (SBLOCA) with a break in a cold leg. The ECC flow was provided from a core makeup tank (CMT) located at a higher elevation than the main part of the primary system. The CMT was pressurized with pipings from the pressurizer and a cold leg. The tests indicated that steam condensation in the CMT can prevent ECC and lead to core uncovery.

  16. Influence of liquid holdup in steam generator U-tubes on small break LOCA severity

    International Nuclear Information System (INIS)

    Leonard, M.T.; Perryman, J.L.; Johnson, G.W.

    1983-01-01

    The severity of small cold leg break loss-of-coolant accidents has been shown to be influenced by liquid holdup in steam generator U-tubes during pump suction loop seal formation in two experiments performed in the Semiscale Mod-2A facility. The core coolant level can be depressed lower than previously thought possible due to a positive hydrostatic head across the steam generators caused by delayed drainage of liquid from the upflow side of the U-tubes. The significance of a lower core coolant level depression is the potential for a more severe temperature excursion occurring during the coolant boiloff phase subsequent to loop seal clearing and prior to accumulator injection. Presented in this paper are the experimental data analysis and supporting computer code calculations that led to these conclusions

  17. Analysis of the SBLOCAs in HANARO pool for the 3-pin fuel test loop

    International Nuclear Information System (INIS)

    Park, S. K.; Chi, D. Y.; Sim, B. S.; Park, K. N.; Ahn, S. H.; Lee, J. M.; Lee, C. Y.; Kim, Y. J.

    2004-09-01

    Fuel Test Loop(FTL) has been developed to meet the increasing demand on fuel irradiation and burn up test required the development of new fuels in Korea. It is designed to provide the test conditions of high pressure and temperature like the commercial PWR and CANDU power plants. And also the FTL have the cooling capability to sufficiently remove the thermal power of the in-pile test section for normal operation, Anticipated Operational Occurrences(AOOs), and Design Basis Accidents(DBAs). This report deals with the Small Break Loss Of Coolant Accidents (SBLOCAs) in HANARO pool for the 3-pin fuel test loop. The MARS code has been used for the prediction of the emergency core cooling capability of the FTL and the peak cladding temperature of the test fuels for the SBLOCAs. The location of the pipe break is assumed at the hill taps connecting the cold and hot legs in HANARO pool to the inlet and outlet nozzles of the In-Pile test Section (IPS). The break size is also assumed less than 20% of the cross section area of the pipe. The test fuels are heated up when the cold leg break occur. However, they are not heated up when the hot leg break occur. The maximum Peak Cladding Temperatures (PCT) are predicted to be about 906.9 .deg. C for the cold leg break accident in PWR fuel test mode and 971.9 .deg. C in CANDU fuel test mode respectively. The critical break size is about the 6% of the cross section area of the pipe for PWR fuel test mode and the 8% for CANDU fuel test mode. The PCTs meet the design criterion of commercial PWR fuel that the maximum PCT is lower than 1204 .deg. C

  18. LOFT/L2-5, Loss of Fluid Test, 3. NRC L2 Large Break LOCA Experiment

    International Nuclear Information System (INIS)

    1992-01-01

    1 - Description of test facility: The LOFT Integral Test Facility is a scale model of a LPWR. The intent of the facility is to model the nuclear, thermal-hydraulic phenomena which would take place in a LPWR during a LOCA. The general philosophy in scaling coolant volumes and flow areas in LOFT was to use the ratio of the LOFT core [50 MW(t)] to a typical LPWR core [3000 MW(t)]. For some components, this factor is not applied; however, it is used as extensively as practical. In general, components used in LOFT are similar in design to those of a LPWR. Because of scaling and component design, the LOFT LOCA is expected to closely model a LPWR LOCA. 2 - Description of test: This experiment was the third of the NRC L2 Series of nuclear large Break LOCA experiments, conducted on 16 June 1981. It simulated a 100% cold leg break with a maximum heat generation of 40 kW/m and rapid pump coast down

  19. Monitoring the vaccine cold chain.

    OpenAIRE

    Cheriyan, E

    1993-01-01

    Maintaining the vaccine cold chain is an essential part of a successful immunisation programme. A continuous electronic temperature monitor helped to identify breaks in the cold chain in the community and the study led to the issue of proper guidelines and replacement of faulty equipment.

  20. INTRA-RATER RELIABILITY OF THE MULTIPLE SINGLE-LEG HOP-STABILIZATION TEST AND RELATIONSHIPS WITH AGE, LEG DOMINANCE AND TRAINING.

    Science.gov (United States)

    Sawle, Leanne; Freeman, Jennifer; Marsden, Jonathan

    2017-04-01

    Balance is a complex construct, affected by multiple components such as strength and co-ordination. However, whilst assessing an athlete's dynamic balance is an important part of clinical examination, there is no gold standard measure. The multiple single-leg hop-stabilization test is a functional test which may offer a method of evaluating the dynamic attributes of balance, but it needs to show adequate intra-tester reliability. The purpose of this study was to assess the intra-rater reliability of a dynamic balance test, the multiple single-leg hop-stabilization test on the dominant and non-dominant legs. Intra-rater reliability study. Fifteen active participants were tested twice with a 10-minute break between tests. The outcome measure was the multiple single-leg hop-stabilization test score, based on a clinically assessed numerical scoring system. Results were analysed using an Intraclass Correlations Coefficient (ICC 2,1 ) and Bland-Altman plots. Regression analyses explored relationships between test scores, leg dominance, age and training (an alpha level of p = 0.05 was selected). ICCs for intra-rater reliability were 0.85 for the dominant and non-dominant legs (confidence intervals = 0.62-0.95 and 0.61-0.95 respectively). Bland-Altman plots showed scores within two standard deviations. A significant correlation was observed between the dominant and non-dominant leg on balance scores (R 2 =0.49, ptest demonstrated strong intra-tester reliability with active participants. Younger participants who trained more, have better balance scores. This test may be a useful measure for evaluating the dynamic attributes of balance. 3.

  1. Horizontal stratified flow model for the 1-D module of WCOBRA/TRAC-TF2: modeling and validation

    Energy Technology Data Exchange (ETDEWEB)

    Liao, J.; Frepoli, C.; Ohkawa, K., E-mail: liaoj@westinghouse.com [Westinghouse Electric Company LLC, LOCA Integrated Services I, Cranberry Twp, Pennsylvania (United States)

    2011-07-01

    For a two-phase flow in a horizontal pipe, the individual phases may separate by gravity. This horizontal stratification significantly impacts the interfacial drag, interfacial heat transfer and wall drag of the two phase flow. For a PWR small break LOCA, the horizontal stratification in cold legs is a highly important phenomenon during loop seal clearance, boiloff and recovery periods. The low interfacial drag in the stratified flow directly controls the time period for the loop clearance and the level of residual water in the loop seal. Horizontal stratification in hot legs also impacts the natural circulation stage of a small break LOCA. In addition, the offtake phenomenon and cold leg condensation phenomenon are also affected by the occurrence of horizontal stratification in the cold legs. In the 1-D module of the WCOBRA/TRAC-TF2 computer code, a horizontal stratification criterion was developed by combining the Taitel-Dukler model and the Wallis-Dobson model, which approximates the viscous Kelvin-Helmholtz neutral stability boundary. The objective of this paper is to present the horizontal stratification model implemented in the code and its assessment against relevant data. The adequacy of the horizontal stratification transition criterion is confirmed by examining the code-predicted flow regime in a horizontal pipe with the measured data in the flow regime map. The void fractions (or liquid level) for the horizontal stratified flow in cold leg or hot leg are predicted with a reasonable accuracy. (author)

  2. Multidimensional analysis of fluid flow in the loft cold leg blowdown pipe during a loss-of-coolant experiment

    International Nuclear Information System (INIS)

    Demmie, P.N.; Hofmann, K.R.

    1979-03-01

    A computer analysis of fluid flow in the Loss-of-Fluid Test (LOFT) cold leg blowdown pipe during a loss-of-coolant experiment (LOCE) was performed using the computer program K-FIX/MOD1. The purpose of this analysis was to evaluate the capability of K-FIX/MOD1 to calculate theoretical fluid quantity distributions in the blowdown pipe during a LOCE for possible application to the analysis of LOFT experimental data, the determination of mass flow, or the development of data reduction models. A rectangular section of a portion of the LOFT blowdown pipe containing measurement Station BL-1 was modeled using time-dependent boundary conditions. Fluid quantities were calculated during a simulation of the first 26 s of LOFT LOCE L1-4. Sensitivity studies were made to determine changes in void fractions and velocities resulting from specific changes in the inflow boundary conditions used for this simulation

  3. Phase controlled metal–insulator transition in multi-leg quasiperiodic optical lattices

    International Nuclear Information System (INIS)

    Maiti, Santanu K.; Sil, Shreekantha; Chakrabarti, Arunava

    2017-01-01

    A tight-binding model of a multi-leg ladder network with a continuous quasiperiodic modulation in both the site potential and the inter-arm hopping integral is considered. The model mimics optical lattices where ultra-cold fermionic or bosonic atoms are trapped in double well potentials. It is observed that, the relative phase difference between the on-site potential and the inter-arm hopping integral, which can be controlled by the tuning of the interfering laser beams trapping the cold atoms, can result in a mixed spectrum of one or more absolutely continuous subband(s) and point like spectral measures. This opens up the possibility of a re-entrant metal–insulator transition. The subtle role played by the relative phase difference mentioned above is revealed, and we corroborate it numerically by working out the multi-channel electronic transmission for finite two-, and three-leg ladder networks. The extension of the calculation beyond the two-leg case is trivial, and is discussed in the work. - Graphical abstract: ▪ - Highlights: • Phase controlled metal–insulator transition is discussed. • An analytical prescription is given to understand MI transition. • Our work provides a way of designing experiments involving laser beams.

  4. ROSA-II test data report, 13

    International Nuclear Information System (INIS)

    1978-07-01

    Results of the ROSA-II test simulating a loss-of-coolant accident (LOCA) in a PWR are presented, including test conditions and interpretations of phenomena observed in test runs 502, 505, 506 and 507. Development tests were performed to find a more effective ECCS injection method than the existing one based on cold leg injection. A combined injection of hot water into upper plenum in early stage of blowdown and subsequent cold water into lower plenum is the most effective method for a cold leg break. A hot leg injection of a low pressure injection system is effective for direct core cooling and early reflooding. The generalization for actual reactors will require analyses with a reliable code. (auth.)

  5. Feasibility study of applying the passive safety system concept to fusion–fission hybrid reactor

    International Nuclear Information System (INIS)

    Yu, Zhang-cheng; Xie, Heng

    2014-01-01

    The fusion–fission hybrid reactor can produce energy, breed nuclear fuel, and handle the nuclear waste, etc., with the fusion neutron source striking the subcritical blanket. The passive safety system consists of passive residual heat removal system, passive safety injection system and automatic depressurization system was adopted into the fusion–fission hybrid reactor in this paper. Modeling and nodalization of primary loop, partial secondary loop and passive core cooling system for the fusion–fission hybrid reactor using relap5 were conducted and small break LOCA on cold leg was analyzed. The results of key transient parameters indicated that the actuation of passive safety system could mitigate the accidental consequence of the 4-inch cold leg small break LOCA on cold leg in the early time effectively. It is feasible to apply the passive safety system concept to fusion–fission hybrid reactor. The minimum collapsed liquid level had great increase if doubling the volume of CMTs to increase its coolant injection and had no increase if doubling the volume of ACCs

  6. Roll type conducting polymer legs for rigid-flexible thermoelectric generator

    Directory of Open Access Journals (Sweden)

    Teahoon Park

    2017-07-01

    Full Text Available A roll-type conducting polymer film was explored as a flexible organic p-type thermoelectric leg using poly(3,4-ethylenedioxythiophene (PEDOT doped with tosylate. The PEDOT films were prepared through solution casting polymerization and rolled up for a roll-type leg. Due to the high flexibility, the roll-type PEDOT leg enabled easy contact to both top and bottom electrodes. Simulation on the dynamic heat transfer and convective cooling for a vertically roosted rod- and roll-type PEDOT leg showed that the temperature difference (ΔT between the hot and cold sides of the leg was much higher in the roll than that of the rod. The PEDOT legs were integrated with n-type Bi2Te3 blocks, to give a 36-couple rigid-flexible thermoelectric generator (RF-TEG. The maximum output voltage from the 36-couple RF-TEG under a ΔT of 7.9 K was determined as 36.7 mV along with a high output power of 115 nW. A wearable RF-TEG was prepared upon the combination of the 36-couple RF-TEG with an arm warmer, to afford an output voltage of 10.6 mV, which was generated constantly and steadily from human wrist heat.

  7. Stratification studies in components of nuclear power plants

    International Nuclear Information System (INIS)

    Randorf, J.A.

    1997-01-01

    The applicability of two stratification criteria during loss-of-coolant (LOCA) conditions was studied. The first criteria was developed for addressing cold water injection-induced stratification. The second criteria applied to downcomer/cold leg junction stratification. Both criteria provided predictions consistent with measured conditions during small break loss-of-coolant tests

  8. Attributing Changing Rates of Temperature Record Breaking to Anthropogenic Influences

    Science.gov (United States)

    King, Andrew D.

    2017-11-01

    Record-breaking temperatures attract attention from the media, so understanding how and why the rate of record breaking is changing may be useful in communicating the effects of climate change. A simple methodology designed for estimating the anthropogenic influence on rates of record breaking in a given time series is proposed here. The frequency of hot and cold record-breaking temperature occurrences is shown to be changing due to the anthropogenic influence on the climate. Using ensembles of model simulations with and without human-induced forcings, it is demonstrated that the effect of climate change on global record-breaking temperatures can be detected as far back as the 1930s. On local scales, a climate change signal is detected more recently at most locations. The anthropogenic influence on the increased occurrence of hot record-breaking temperatures is clearer than it is for the decreased occurrence of cold records. The approach proposed here could be applied in rapid attribution studies of record extremes to quantify the influence of climate change on the rate of record breaking in addition to the climate anomaly being studied. This application is demonstrated for the global temperature record of 2016 and the Central England temperature record in 2014.

  9. ROSA-V/LSTF vessel top head LOCA tests SB-PV-07 and SB-PV-08 with break sizes of 1.0 and 0.1% and operator recovery actions for core cooling

    International Nuclear Information System (INIS)

    Suzuki, Mitsuhiro; Takeda, Takeshi; Nakamura, Hideo

    2010-02-01

    A series of break size parameter tests (SB-PV-07 and SB-PV-08) were conducted at the Large Scale Test Facility (LSTF) of ROSA-V Program by simulating a vessel top small break loss-of-coolant accident (SBLOCA) at a pressurized water reactor (PWR). Typical phenomena to the vessel top break LOCA and effectiveness of operator recovery actions on core cooling were studied under an assumption of total failure of high pressure injection (HPI) system. The LSTF simulates a 4-loop 3423 MWt PWR by a full-height, full-pressure and 1/48 volume scaling two-loop system. Typical phenomena of vessel top break LOCA are clarified for the cases with break sizes of 1.0 and 0.1% cold leg break equivalent. The results from a 0.5% top break LOCA test (SB-PV-02) in the early ROSA-IV Program was referred during discussion. Operator actions of HPI recovery in the 1.0% top break test and steam generator (SG) depressurization in the 0.1% top break test were initiated when temperature at core exit thermocouple (CET) reached 623 K during core boil-off. Both operator actions resulted in immediate recovery of core cooling. Based on the obtained data, several thermal-hydraulic phenomena were discussed further such as relations between vessel top head water level and steam discharge at the break, and between coolant mass inventory transient and core heat-up and quench behavior, and CET performances to detect core heat-up under influences of three-dimensional (3D) steam flows in the core and core exit. (author)

  10. Two-dimensional thermal-hydraulic behavior in core in SCTF Core-II cold leg injection tests

    International Nuclear Information System (INIS)

    Iwamura, Takamichi; Sobajima, Makoto; Okubo, Tsutomu; Ohnuki, Akira; Abe, Yutaka; Adachi, Hiromichi

    1985-07-01

    Major purpose of the Slab Core Test Program is to investigate the two-dimensional thermal-hydraulic behavior in the core during the reflood phase in a PWR-LOCA. In order to investigate the effects of radial power profile, three cold leg injection tests with different radial power profiles under the same total heating power and core stored energy were performed by using the Slab Core Test Facility (SCTF) Core-II. It was revealed by comparing these three tests that the heat transfer was enhanced in the higher power bundles and degraded in the lower power bundles in the non-uniform radial power profile tests. The turnaround temperature in the high power bundles were evaluated to be reduced by about 40 to 120 K. On the other hand, a two-dimensional flow in the core was also induced by the non-uniform water accumulation in the upper plenum and the quench was delayed resultantly in the bundles corresponding to the peripheral bundles of a PWR. However, the effect of the non-uniform upper plenum water accumulation on the turnaround temperature was small because the effect dominated after the turnaround of the cladding temperature. Selected data from Tests S2-SH1, S2-SH2 and S2-O6 are also presented in this report. Some data from Tests S2-SH1 and S2-SH2 were compared with TRAC post-test calculations performed by the Los Alamos National Laboratory. (author)

  11. Simulation of the IAEA's fourth Standard Problem Exercise small-break loss-of-coolant accident using RELAP5/MOD.3.1

    International Nuclear Information System (INIS)

    Cebull, P.P.; Hassan, Y.A.

    1995-01-01

    A small-break loss-of-coolant accident experiment conducted at the PMK-2 integral test facility in Hungary is analyzed using the RELAP5/MOD3.1 thermal-hydraulic code. The experiment simulated a 7.4% break in the cold leg of a VVER-440/213-type nuclear power plant as part of the International Atomic Energy Agency's Fourth Standard Problem Exercise (SPE-4). Blind calculations of the exercise are presented, and the timing of various events throughout the transient is discussed. A posttest analysis is performed in which the sensitivity of the calculated results is investigated. The code RELAP5 predicts most of the transient events well, although a few problems are noted, particularly the failure of RELAP5 to predict dryout in the core even through the collapsed liquid level fell below the top of the heated portion. A discrepancy between the predicted primary mass inventory distribution and the experimental data is identified. Finally, the primary and secondary pressures calculated by RELAP5 fell too rapidly during the latter part of the transient, resulting in rather large errors in the predicted timing of some pressure-actuated events

  12. PCTRAN enhancement for large break loss of coolant accident concurrent with loss of offsite power in VVER-1000 simulation

    Energy Technology Data Exchange (ETDEWEB)

    Hadad, Kamal; Esmaeili-Sanjavanmareh, Mansour [Shiraz Univ., Shiraz (Iran, Islamic Republic of). Dept. of Nuclear Engineering

    2017-05-15

    PCTRAN capability to simulate a large break loss of coolant accident concurrent with the loss of offsite power in Bushehr Nuclear Power Plant is enhanced and investigated. Following the correction of the accident scenario for Bushehr nuclear power plant in PCTRAN, simulation results are compared with the final safety assessment report of that plant. As a result, the primary loop thermal hydraulics parameters including pressure, total flow rates, leakage flow rates and reactor power are in a good agreement with the reference data. Hot and cold leg temperature variations have the same trends as reference data but have a maximum of 80 C disagreement at the transient initiation. The reason for this disagreement is explained and its adjustment is discussed. Improvements of PCTRAN simulator are mainly due to enhancing user control for atmospheric steam dump valve, containment pressure and emergency core cooling systems which are thoroughly described in this paper.

  13. Assessment of TRAC-PF1/MOD1 code for large break LOCA in PWR

    International Nuclear Information System (INIS)

    Akimoto, Hajime; Ohnuki, Akira; Murao, Yoshio; Abe, Yutaka.

    1993-03-01

    As the first step of the REFLA/TRAC code development, the TRAC/PF1/MOD1 code has been assessed for various experiments that simulate postulated large-break loss-of-coolant accident (LBLOCA) in PWR to understand the predictive capability and to identify the problem areas of the code. The assessment calculations were performed for separate effect tests for critical flow, counter current flow, condensation at cold leg and reflood as well as integral tests to understand predictability for individual phenomena. This report summarizes results from the assessment calculations of the TRAC-PF1/MOD1 code for LBLOCA in PWR. The assessment calculations made clear the predictive capability and problem areas of the TRAC-PF1/MOD1 code for LBLOCA in PWR. The areas, listed below, should be improved for more realistic and effective simulation of LBLOCA in PWR: (1) core heat transfer model during blowdown, (2) ECC bypass model at downcomer during refill, (3) condensation model during accumulator injection, and (4) core thermal hydraulic model during reflood. (author) 57 refs

  14. A simple blowdown code for SUPER-SARA loop conditions

    International Nuclear Information System (INIS)

    Fritz, G.

    1981-01-01

    The Super Sara test programme (SSTP) is aimed to study in pile the fuel and cluster behaviour under two types of accident conditions: - the ''Large break loss of coolant'' condition (LB-Loca), - the ''Severe fuel damage'' (SFD) in a boildown caused by a small break. BIVOL was developed for the LB-Loca situation. This code is made for a loop where essentially two volumes define the thermohydraulics during the blowdown. In the SUPERSARA loop these two volumes are represented by the hot leg and cold leg pipings together with the respective upper and lower plenum of the test section

  15. Estimation of regional cutaneous cold sensitivity by analysis of the gasping response.

    Science.gov (United States)

    Burke, W E; Mekjavić, I B

    1991-11-01

    Regional cutaneous sensitivity to cooling was assessed in males by separately immersing four discrete skin regions in cold water (15 degrees C) during head-out immersion. The response measured was gasping at the onset of immersion; the gasping response appears to be the result of a nonthermoregulatory neurogenic drive from cutaneous cold receptors. Subjects of similar body proportions wore a neoprene "dry" suit modified to allow exposure to the water of either the arms, upper torso, lower torso, or legs, while keeping the unexposed skin regions thermoneutral. Each subject was immersed to the sternal notch in all four conditions of partial exposure plus one condition of whole body exposure. The five cold water conditions were matched by control immersions in lukewarm (34 degrees C) water, and trials were randomized. The magnitude of the gasping response was determined by mouth occlusion pressure (P0.1). For each subject, P0.1 values for the 1st min of immersion were integrated, and control trial values, although minimal, were subtracted from their cold water counterpart to account for any gasping due to the experimental design. Results were averaged and showed that the highest P0.1 values were elicited from whole body exposure, followed in descending order by exposures of the upper torso, legs, lower torso, and arms. Correction of the P0.1 response for differences in exposed surface area (A) and cooling stimulus (delta T) between regions gave a cold sensitivity index [CSI, P0.1/(A.delta T)] for each region and showed that the index for the upper torso was significantly higher than that for the arms or legs; no significant difference was observed between the indexes for the upper and lower torso.(ABSTRACT TRUNCATED AT 250 WORDS)

  16. Modeling operator actions during a small break loss-of-coolant accident in a Babcock and Wilcox nuclear power plant

    International Nuclear Information System (INIS)

    Ghan, L.S.; Ortiz, M.G.

    1991-01-01

    A small break loss-of-accident (SBLOCA) in a typical Babcock and Wilcox (B ampersand W) nuclear power plant was modeled using RELAP5/MOD3. This work was performed as part of the United States Regulatory Commission's (USNRC) Code, Scaling, Applicability and Uncertainty (CSAU) study. The break was initiated by severing one high pressure injection (HPI) line at the cold leg. Thus, the small break was further aggravated by reduced HPI flow. Comparisons between scoping runs with minimal operator action, and full operator action, clearly showed that the operator plays a key role in recovering the plant. Operator actions were modeled based on the emergency operating procedures (EOPs) and the Technical Bases Document for the EOPs. The sequence of operator actions modeled here is only one of several possibilities. Different sequences of operator actions are possible for a given accident because of the subjective decisions the operator must make when determining the status of the plant, hence, which branch of the EOP to follow. To assess the credibility of the modeled operator actions, these actions and results of the simulated accident scenario were presented to operator examiners who are familiar with B ampersand W nuclear power plants. They agreed that, in general, the modeled operator actions conform to the requirements set forth in the EOPs and are therefore plausible. This paper presents the method for modeling the operator actions and discusses the simulated accident scenario from the viewpoint of operator actions

  17. Small break critical discharge: The roles of vapor and liquid entrainment in a stratified two-phase region upstream of the break

    International Nuclear Information System (INIS)

    Schrock, V.E.; Revankar, S.T.; Mannheimer, R.; Wang, C.H.

    1986-12-01

    The main objective of this research program was to perform an experimental investigation on the phenomena of two-phase critical flow through small break from a horizontal pipe which contained a stratified two phase flow. Stagnation conditions investigated were saturated steam-water, and air-cold water at pressures ranging from 0.37 MPa to 1.07 MPa. The small breaks employed were cylindrical tubes of diameters 3.96 mm, 6.32 mm, and 10.1 mm with sharp-edged entrance. For breaks resulting from a small hole in a primary coolant pipe or in a small pipe, a sharp-edged orifice or a sharp-edged tube can be the approximation

  18. High performance p-type segmented leg of misfit-layered cobaltite and half-Heusler alloy

    International Nuclear Information System (INIS)

    Hung, Le Thanh; Van Nong, Ngo; Snyder, G. Jeffrey; Viet, Man Hoang; Balke, Benjamin; Han, Li; Stamate, Eugen; Linderoth, Søren; Pryds, Nini

    2015-01-01

    Highlights: • p-type segmented leg of oxide and half-Heusler was for the first time demonstrated. • The maximum conversion efficiency reached a value of about 5%. • The results are among the highest reported values so far for oxide-based legs. • Oxide-based segmented leg is very promising for generating electricity. - Abstract: In this study, a segmented p-type leg of doped misfit-layered cobaltite Ca 2.8 Lu 0.15 Ag 0.05 Co 4 O 9+δ and half-Heusler Ti 0.3 Zr 0.35 Hf 0.35 CoSb 0.8 Sn 0.2 alloy was fabricated and characterized. The thermoelectric properties of single components, segmented leg, and the electrical contact resistance of the joint part were measured as a function of temperature. The output power generation characteristics of segmented legs were characterized in air under various temperature gradients, ΔT, with the hot side temperature up to 1153 K. At ΔT ≈ 756 K, the maximum conversion efficiency reached a value of ∼5%, which is about 65% of that expected from the materials without parasitic losses. The long-term stability investigation for two weeks at the hot and cold side temperatures of 1153/397 K shows that the segmented leg has good durability as a result of stable and low electrical resistance contacts

  19. ROSA/LSTF experiment report for RUN SB-CL-24 repeated core heatup phenomena during 0.5% cold leg break LOCA

    Energy Technology Data Exchange (ETDEWEB)

    Suzuki, Mitsuhiro; Anoda, Yoshinari [Department of Reactor Safety Research, Nuclear Safety Research Center, Tokai Research Establishment, Japan Atomic Energy Research Institute, Tokai, Ibaraki (Japan)

    2000-03-01

    A small break loss-of-coolant accident (SBLOCA) in a Westinghouse-type four-loop PWR was simulated in an experiment (SB-CL-24) conducted at the Large-Scale Test Facility (LSTF) with an intention to study repeated core heatup during a long-term cooldown process. The experiment was conducted on February 28, 1990 with specified test conditions including failure assumptions both on the high pressure injection (HPI) and the auxiliary feedwater systems, and the intentional secondary system depressurization as an operator action. The secondary depressurization contributed to promote the primary depressurization and the actuation of accumulator injection system (AIS). A temporary core heatup was observed in each of three loopseal clearing (LSC) processes. A significant core heatup occurred in the following boil-off process after loss of the secondary coolant mass and the AIS termination due to increase of the primary pressure. By additional opening of the pressurizer relief valves and safety valves, the primary pressure rapidly decreased to result in the low pressure injection (LPI) which cooled the heated core. This report summarizes results of the experiment (SB-CL-24) in addition to typical responses of some accident indication systems including the core exit thermocouples (CETs) and the water level meters in the primary system. (author)

  20. Axion cold dark matter in nonstandard cosmologies

    International Nuclear Information System (INIS)

    Visinelli, Luca; Gondolo, Paolo

    2010-01-01

    We study the parameter space of cold dark matter axions in two cosmological scenarios with nonstandard thermal histories before big bang nucleosynthesis: the low-temperature reheating (LTR) cosmology and the kination cosmology. If the Peccei-Quinn symmetry breaks during inflation, we find more allowed parameter space in the LTR cosmology than in the standard cosmology and less in the kination cosmology. On the contrary, if the Peccei-Quinn symmetry breaks after inflation, the Peccei-Quinn scale is orders of magnitude higher than standard in the LTR cosmology and lower in the kination cosmology. We show that the axion velocity dispersion may be used to distinguish some of these nonstandard cosmologies. Thus, axion cold dark matter may be a good probe of the history of the Universe before big bang nucleosynthesis.

  1. Analysis of th SBLOCAs in the room 1 for the 3-pin fuel test loop

    International Nuclear Information System (INIS)

    Park, S. K.; Chi, D. Y.; Sim, B. S.; Park, K. N.; Ahn, S. H.; Lee, J. M.; Lee, C. Y.; Kim, Y. J.

    2004-10-01

    Fuel Test Loop(FTL) has been developed to meet the increasing demand on fuel irradiation and burn up test required the development of new fuels in Korea. It is designed to provide the test conditions of high pressure and temperature like the commercial PWR and CANDU power plants. And also the FTL have the cooling capability to sufficiently remove the thermal power of the in-pile test section for normal operation, Anticipated Operational Occurrences(AOOs), and Design Basis Accidents(DBAs). This report deals with the Small Break Loss of Coolant Accidents (SBLOCAs) in the Room 1 for the 3-pin fuel test loop. The MARS code has been used for the prediction of the emergency core cooling capability of the FTL and the peak cladding temperature of the test fuels for the SBLOCAs. The location of the pipe break is assumed at the downstream of the main cooling water pump and the upstream of the main cooler in the room 1. The break size is also assumed less than 20% of the cross section area of the pipe. The test fuels are heated up when the cold leg break occur. However, they are not heated up when the hot leg break occur. The maximum Peak Cladding Temperature (PCT) is predicted to be about 931.4 .deg. C for the cold leg break accident in PWR fuel test mode and 931.6 .deg. C in CANDU fuel test mode respectively. The critical break size is about the 8% of the cross section area of the pipe for PWR fuel test mode and the 10% for CANDU fuel test mode. The PCTs meet the design criterion of commercial PWR fuel that the maximum PCT is lower than 1204 .deg. C

  2. Measurement of L-[1-14C]leucine kinetics in splanchnic and leg tissues in humans. Effect of amino acid infusion

    International Nuclear Information System (INIS)

    Gelfand, R.A.; Glickman, M.G.; Castellino, P.; Louard, R.J.; DeFronzo, R.A.

    1988-01-01

    Although whole-body leucine flux is widely measured to study body protein turnover in humans, the contribution of specific tissues to the total-body measurement remains unknown. By combining the organ-balance technique with the systemic infusion of L-[1-14C]leucine, we quantitated leucine production and disposal by splanchnic and leg tissues and by the whole body, simultaneously, in six normal men before and during amino acid infusion. At steady state, disposal of arterial leucine by splanchnic and leg tissues was calculated from the percent extraction (E) of L-[1-14C]leucine counts: uptake = E x [Leu]a x flow. Tissue release of cold leucine (from protein turnover) into vein was calculated as the difference between leucine uptake and the net tissue leucine balance. In the postabsorptive state, despite substantial (P less than .01) extraction of L-[1-14C]leucine by splanchnic (23 +/- 1%) and leg (18 +/- 2%) tissues, net leucine balance across both tissue beds was small, indicating active simultaneous disposal and production of leucine at nearly equivalent rates. Splanchnic tissues accounted for approximately 50% of the measured total-body leucine flux. During amino acid infusion, the net leucine balance across splanchnic and leg tissues became positive, reflecting not only an increase in leucine uptake but also a marked suppression (by approximately 50%, P less than .02) of cold leucine release. This reduction in splanchnic and leg leucine release was indicated by a sharp decline in whole-body endogenous leucine flux

  3. Flow regimes and heat transfer modes identification in ANGRA 2 core, during small break in the primary loop with area of 100 cm2, simulated with RELAP5 code

    International Nuclear Information System (INIS)

    Borges, Eduardo M.; Sabundjian, Gaiane

    2015-01-01

    Identifying the flow regimes and the heat transfer modes is important for the analysis of accidents such as the Loss-of-Coolant Accident (LOCA). The aim of this paper is to identify the flow regimes, the heat transfer modes, and the correlations used in the RELAP5/MOD3.2.gama code in ANGRA 2 during the Small-Break Loss-of-Coolant Accident (SBLOCA) with a 100cm 2 -rupture area in the cold leg of primary loop. The Chapter 15 of the Final Safety Analysis Report of ANGRA 2 (FSAR - A2) reports this specific kind of accident. The results from this work demonstrated the several flow regimes and heat transfer modes that can be present in the core of ANGRA 2 during the postulated accident. (author)

  4. Simulation of a loss of primary coolant accident due to a large break in Angra 2 Nuclear Power Plant with RELAP5/MOD3.2.2G code

    International Nuclear Information System (INIS)

    Sabunddjian, Gaiane; Andrade, Delvonei Alves de

    2003-01-01

    This work presents the simulation, with RELAP5/MOD.3.2.2G code, of the postulate accident with loss of coolant in the primary circuit for large break (LBLOCA), which is described in Chapter 15 of the Final Safety Analysis Report of Angra 2 FSAR. The accident consists basically of the total break of the cold leg (Loop 20) of Angra 2 Plant. The rupture area considered is 4418 cm 2 , which represents 100% of the primary circuit pipe flow area. The Emergency Core Cooling System (ECCS) efficiency is also verified for this accident. In this simulation, failure and repair criteria are adopted for the ECCS components, in order to verify the system operation, in carrying out its function as expected by the project to preserve the integrity of the reactor core and to guarantee its cooling. LBLOCA accidents are characterized by a fast blowdown in the primary circuit to values that the low pressure injection system is activated and then, followed by the water injection by the accumulators. The thermal-hydraulic processes inherent to the accident phenomenon, such as hot leg vaporization and consequently core vaporization causing an inappropriate flow distribution in the reactor core, can lead to a reduction in the core liquid level, until the ECCS is capable to reflood it. It is important to point out that the results do not represent an independent calculation for the licensing process, but a calculation to give support to the qualification process of Angra 2 transient basic nodalization (author)

  5. Performance of core exit thermocouple for PWR accident management action in vessel top break LOCA simulation experiment at OECD/NEA ROSA project

    International Nuclear Information System (INIS)

    Suzuki, Mitsuhiro; Takeda, Takeshi; Nakamura, Hideo

    2009-01-01

    Presented are experiment results of the Large Scale Test Facility (LSTF) conducted at the Japan Atomic Energy Agency (JAEA) with a focus on core exit thermocouple (CET) performance to detect core overheat during a vessel top break loss-of-coolant accident (LOCA) simulation experiment. The CET temperatures are used to start accident management (AM) action to quickly depressurize steam generator (SG) secondary side in case of core temperature excursion. Test 6-1 is first test of the OECD/NEA ROSA Project started in 2005, simulating withdraw of a control rod drive mechanism penetration nozzle at the vessel top head. The break size is equivalent to 1.9% cold leg break. The AM action was initiated when CET temperature rose up to 623K. There was no reflux water fallback onto the CETs during the core heat-up period. The core overheat, however, was detected with a time delay of about 230s. In addition, a large temperature discrepancy was observed between the CETs and the hottest core region. This paper clarifies the reason of time delay and temperature discrepancy between the CETs and heated core during boil-off including three-dimensional steam flows in the core and core exit. The paper discusses applicability of the LSTF CET performance to pressurized water reactor (PWR) conditions and a possibility of alternative indicators for earlier AM action than in Test 6-1 is studied by using symptom-based plant parameters such as a reactor vessel water level detection. (author)

  6. SPES-2, AP600 intergral system test S01007 2 inch CL to core make-up tank pressure balance line break

    Energy Technology Data Exchange (ETDEWEB)

    Bacchiani, M.; Medich, C.; Rigamonti, M. [SIET S.p.A. Piacenza (Italy)] [and others

    1995-09-01

    The SPES-2 is a full height, full pressure experimental test facility reproducing the Westinghouse AP600 reactor with a scaling factor of 1/395. The experimental plant, designed and operated by SIET in Piacenza, consists of a full simulation of the AP600 primary core cooling system including all the passive and active safety systems. In 1992, Westinghouse, in cooperation with ENEL (Ente Nazionale per l` Energia Elettrica), ENEA (Enter per le numove Technlogie, l` Energia e l` Ambient), Siet (Societa Informazioni Esperienze Termoidraulich) and ANSALDO developed an experimental program to test the integrated behaviour of the AP600 passive safety systems. The SPES-2 test matrix, concluded in November 1994, has examined the AP600 passive safety system response for a range of small break LOCAs at different locations on the primary system and on the passive system lines; single steam generator tube ruptures with passive and active safety systems and a main steam line break transient to demonstrate the boration capability of passive safety systems for rapid cooldown. Each of the tests has provided detailed experimental results for verification of the capability of the analysis methods to predict the integrated passive safety system behaviour. Cold and hot shakedown tests have been performed on the facility to check the characteristics of the plant before starting the experimental campaign. The paper first presents a description of the SPES-2 test facility then the main results of S01007 test {open_quotes}2{close_quotes} Cold Leg (CL) to Core Make-up Tank (CMT) pressure balance line break{close_quotes} are reported and compared with predictions performed using RELAP5/mod3/80 obtained by ANSALDO through agreement with U.S.N.R.C. (U.S. Nuclear Regulatory Commission). The SPES-2 nodalization and all the calculations here presented were performed by ANSALDO and sponsored by ENEL as a part of pre-test predictions for SPES-2.

  7. Security in Northern Europe after the Cold War

    National Research Council Canada - National Science Library

    Besserudhagen, Svein

    1995-01-01

    The end of the Cold War came with dramatic changes in Europe. NATO is searching for its future in a Europe threatened by instability and break down of government control and law and order in Russia...

  8. An analysis of the influence of logistics activities on the export cold chain of temperature sensitive fruit through the Port of Cape Town

    Directory of Open Access Journals (Sweden)

    Leila L. Goedhals-Gerber

    2015-09-01

    Full Text Available Background: South Africa exports a large variety of different fruit types and cultivars worldwide. Yet, there is concern in the South African fruit industry that too much fruit and money is lost each year due to breaks along the fresh fruit export cold chain. Objective: The objective of this article was to identify the influence of logistics activities on breaks along the South African fruit export cold chain. The focus is specifically on temperature sensitive fruit, exported in refrigerated containers to Europe and the United Kingdom through the Port of Cape Town. This supply chain was selected as this was the most accessible supply chain in terms of retrieving the necessary temperature data. Method: The cold chain was investigated from the cold store, through all segments, until the Port of Cape Town. Temperature data collected with temperature monitoring devices from different fruit export supply chains of grapes, plums and pome fruit (apples and pears were analysed to identify the percentage of temperature breaks and the length of temperature breaks that occur at each segment of the cold chain. Results: The results show that a large number of breaks are experienced along South Africa’s fruit export cold chain, specifically at the interface between the cold store and the truck. In addition, the findings also show that there has been an improvement in the number of breaks experienced in the Port of Cape Town following the implementation of the NAVIS and Refcon systems. Conclusion: This article concludes by providing the fruit industry with areas that require addressing to improve operational procedures along the fruit export cold chain to help ensure that the fruit arrives at its final destination at optimal quality.

  9. Flow regimes and heat transfer modes identification in ANGRA 2 core, during small break in the primary loop with area of 100 cm{sup 2}, simulated with RELAP5 code

    Energy Technology Data Exchange (ETDEWEB)

    Borges, Eduardo M.; Sabundjian, Gaiane, E-mail: gdgian@ipen.br, E-mail: borges.em@hotmail.com [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2015-07-01

    Identifying the flow regimes and the heat transfer modes is important for the analysis of accidents such as the Loss-of-Coolant Accident (LOCA). The aim of this paper is to identify the flow regimes, the heat transfer modes, and the correlations used in the RELAP5/MOD3.2.gama code in ANGRA 2 during the Small-Break Loss-of-Coolant Accident (SBLOCA) with a 100cm{sup 2}-rupture area in the cold leg of primary loop. The Chapter 15 of the Final Safety Analysis Report of ANGRA 2 (FSAR - A2) reports this specific kind of accident. The results from this work demonstrated the several flow regimes and heat transfer modes that can be present in the core of ANGRA 2 during the postulated accident. (author)

  10. A through calculation of 1,100 MWe PWR large break LOCA by THYDE-P1 EM model

    International Nuclear Information System (INIS)

    Kanazawa, Masayuki; Asahi, Yoshiro; Hirano, Masashi

    1984-07-01

    THYDE-P1 is a code to analyze both the blowdown and refill-reflood phases of loss-of-coolant accidents (LOCAs) of pressurized water reactors (PWRs). Up to now, THYDE-P1 has been applied to various experiment analyses, which show its high capability to analyze LOCAs as a best estimate (BE) calculation code. In this report, evaluation model (EM) calculation method, especialy in the blowdown and refill phases, is established equivalently to WREM/J2 which is regarded as appropriate for an EM calculation code, and the results of them are compared and discussed. The present calculation was the first executed by THYDE-P1-EM, and was performed as Sample Calculation Run 80 which was a part of a series of THYDE-P sample calculations. The calculation was carried out from the LOCA initiation till 400 seconds for a guillotine break at the cold leg of a commercial 1,100 MWe PWR plant. The calculated results agreed well to that of the WREM/J2 code. (author)

  11. Experiment on performance of upper head injection system with ROSA-II

    International Nuclear Information System (INIS)

    1976-09-01

    Thermo-hydraulic behavior in the primary cooling system of a pressurized water reactor with an upper head injection system (UHI) in a postulated loss-of-coolant accident (LOCA) has been studied with ROSA-II test facility. Simulated UHI and internal structures of the pressure vessel were installed to the facility for the experiment. Nine maximum-sized double-ended break tests and one medium-sized split break test were performed for the cold-leg break condition. The results are as follows: (1) Fluid mixing in the upper head is not perfect. (2) Cold water injection into the steam or two-phase fluid causes violent depressurization due to the condensation. Flow pattern in the primary cooling system is largely influenced by the above two. (auth.)

  12. Task driven optimal leg trajectories in insect-scale legged microrobots

    Science.gov (United States)

    Doshi, Neel; Goldberg, Benjamin; Jayaram, Kaushik; Wood, Robert

    Origami inspired layered manufacturing techniques and 3D-printing have enabled the development of highly articulated legged robots at the insect-scale, including the 1.43g Harvard Ambulatory MicroRobot (HAMR). Research on these platforms has expanded its focus from manufacturing aspects to include design optimization and control for application-driven tasks. Consequently, the choice of gait selection, body morphology, leg trajectory, foot design, etc. have become areas of active research. HAMR has two controlled degrees-of-freedom per leg, making it an ideal candidate for exploring leg trajectory. We will discuss our work towards optimizing HAMR's leg trajectories for two different tasks: climbing using electroadhesives and level ground running (5-10 BL/s). These tasks demonstrate the ability of single platform to adapt to vastly different locomotive scenarios: quasi-static climbing with controlled ground contact, and dynamic running with un-controlled ground contact. We will utilize trajectory optimization methods informed by existing models and experimental studies to determine leg trajectories for each task. We also plan to discuss how task specifications and choice of objective function have contributed to the shape of these optimal leg trajectories.

  13. Experiment data report for semiscale Mod-1 Test S-06-5. (LOFT counterpart test)

    International Nuclear Information System (INIS)

    1977-06-01

    Recorded test data are presented for Test S-06-5 of the Semiscale Mod-1 LOFT counterpart test series. These tests are among several Semiscale Mod-1 experiments conducted to investigate the thermal and hydraulic phenomena accompanying a hypothesized loss-of-coolant accident in a pressurized water reactor (PWR) system. Test S-06-5 was conducted from initial conditions of 2272 psia and 536 0 F to investigate the response of the Semiscale Mod-1 system to a depressurization and reflood transient following a simulated double-ended offset shear of the broken loop cold leg piping. During the test, cooling water was injected into the cold legs of the intact and broken loops to simulate emergency core coolant injection in a PWR. The purpose of Test S-06-5 was to assess the influence of the break nozzle geometry on core thermal and system response and on the subcooled and low quality mass flow rates at the break locations

  14. ANALISIS KONDISI TERAS REAKTOR DAYA MAJU AP1000 PADA KECELAKAAN SMALL BREAK LOCA

    Directory of Open Access Journals (Sweden)

    Andi Sofrany Ekariansyah

    2015-06-01

    , mixture level, temperatur kelongsong, small break LOCA, RELAP5.   ABSTRACT ANALYSIS ON THE CORE CONDITION OF AP1000 ADVANCED POWER REACTOR DURING SMALL BREAK LOCA. Accident due to the loss of coolant from the reactor boundary is an anticipated design basis event in the design of power reactor adopting the Generation II up to IV technology. Small break LOCA leads to more significant impact on safety compared to the large break LOCA as shown in the Three-Mile Island (TMI. The focus of this paper is the small break LOCA analysis on the Generation III+ advanced power reactor of AP1000 by simulating three different initiating events, which are inadvertent opening of Automatic Depressurization System (ADS, double-ended break on one of Direct Vessel Injection (DVI pipe, and 10 inch diameter split break on one of cold leg pipe. Methodology used is by simulating the events on the AP1000 model developed using RELAP5/SCDAP/Mod3.4. The impact analyzed is the core condition during the small break LOCA consisting of the mixture level occurrence and the fuel cladding temperature transient. The results show that the mixture level for all small break LOCA events are above the active core height, which indicates no core uncovery event. The development of the mixture level affect the fuel cladding temperature transient, which shows a decreasingly trend after the break, and the effectifeness of core cooling. Those results are identical with the results of other code of NOTRUMP. The resulted core cooling is also due to the function of coolant injection from passive safety feature, which is unique in the AP1000 design. In overall, the result of analysis shows that the AP1000 model developed by the RELAP5 can be used for analysis of design basis accident considered in the AP1000 advanced power reactor. Keywords: analysis, mixture level, fuel cladding temperature, small break LOCA, RELAP5.

  15. THE EFFECTS OF SINGLE LEG HOP PROGRESSION AND DOUBLE LEGS HOP PROGRESSION EXERCISE TO INCREASE SPEED AND EXPLOSIVE POWER OF LEG MUSCLE

    Directory of Open Access Journals (Sweden)

    Nining W. Kusnanik

    2015-05-01

    Full Text Available The main purpose of this study was to determine the effect of single leg hop progression and double legs hop progression exercise to increase speed and explosive power of leg muscles. Plyometric is one of the training methods that can increase explosive power. There are many models of plyometric training including single leg hop progression and double leg hop progression. This research was experimental using match subject design techniques. The subjects of this study were 39 students who joined basketball school club. There were 3 groups in this study: Group 1 were 13 students who given sin¬gle leg hop progression exercise, Group 2 were 13 students who given double legs hop progression exercise, Group 3 were 13 students who given conventional exercise. The data was collected during pre test and post test by testing 30m speed running and vertical jump. The data was analyzed using Analysis of Varians (Anova. It was found that there were significantly increased on speed and explosive power of leg muscles of Group 1 and Group 2. It can be stated that single leg hop progression exercise was more effective than double leg hop progression exercise. The recent findings supported the hypothesis that single leg hop progression and double legs hop progression exercise can increase speed and explosive power of leg muscles. These finding were supported by some previous studies (Singh, et al, 2011; Shallaby, H.K., 2010. The single leg hop progression is more effective than double legs hop progression. This finding was consistent with some previous evidences (McCurdy, et al, 2005; Makaruk et al, 2011.

  16. Impact of UK NICE clinical guidelines 168 on referrals to a specialist academic leg ulcer service.

    Science.gov (United States)

    Davies, Huw Ob; Popplewell, Matthew; Bate, Gareth; Kelly, Lisa; Darvall, Katy; Bradbury, Andrew W

    2018-03-01

    Background Leg ulcers are a common cause of morbidity and disability and result in significant health and social care expenditure. The UK National Institute for Health and Care Excellence (NICE) Clinical Guideline (CG)168, published in July 2013, sought to improve care of patients with leg ulcers, recommending that patients with a break in the skin below the knee that had not healed within two weeks be referred to a specialist vascular service for diagnosis and management. Aim Determine the impact of CG168 on referrals to a leg ulcer service. Methods Patients referred with leg ulceration during an 18-month period prior to CG168 (January 2012-June 2013) and an 18-month period commencing six months after (January 2014-June 2015) publication of CG168 were compared. Results There was a two-fold increase in referrals (181 patients, 220 legs vs. 385 patients, 453 legs) but no change in mean age, gender or median-duration of ulcer at referral (16.6 vs. 16.2 weeks). Mean-time from referral to specialist appointment increased (4.8 vs. 6 weeks, p = 0.0001), as did legs with superficial venous insufficiency (SVI) (36% vs. 44%, p = 0.05). There was a trend towards more SVI endovenous interventions (32% vs. 39%, p = 0.271) with an increase in endothermal (2 vs. 32 legs, p = 0.001) but no change in sclerotherapy (24 vs. 51 legs) treatments. In both groups, 62% legs had compression. There was a reduction in legs treated conservatively with simple dressings (26% vs. 15%, p = 0.0006). Conclusions Since CG168, there has been a considerable increase in leg ulcer referrals. However, patients are still not referred until ulceration has been present for many months. Although many ulcers are multi-factorial and the mainstay of treatment remains compression, there has been an increase in SVI endovenous intervention. Further efforts are required to persuade community practitioners to refer patients earlier, to educate patients and encourage further investment in

  17. Predictions of stratification in cold leg components using virtual noding schemes

    International Nuclear Information System (INIS)

    Piper, R.B.; Hassan, Y.A.; Banerjee, S.S.; Barsamian, H.R.; Cebull, P.P.

    1996-01-01

    In this investigation, a virtual noding scheme is used with RELAP5/MOD3.2 to capture thermal stratification effects in a small-break loss-of-coolant accident (LOCA) simulation. A three-dimensional code (CFD-ACE) has also been used to observe the stratification effects in a similar situation. Stratification temperature differences of the simulations compare well with that of the experiment. The Froude number was also evaluated

  18. Topological phases in frustrated synthetic ladders with an odd number of legs

    Science.gov (United States)

    Barbarino, Simone; Dalmonte, Marcello; Fazio, Rosario; Santoro, Giuseppe E.

    2018-01-01

    The realization of the Hofstadter model in a strongly anisotropic ladder geometry has now become possible in one-dimensional optical lattices with a synthetic dimension. In this work, we show how the Hofstadter Hamiltonian in such ladder configurations hosts a topological phase of matter which is radically different from its two-dimensional counterpart. This topological phase stems directly from the hybrid nature of the ladder geometry and is protected by a properly defined inversion symmetry. We start our analysis by considering the paradigmatic case of a three-leg ladder which supports a topological phase exhibiting the typical features of topological states in one dimension: robust fermionic edge modes, a degenerate entanglement spectrum, and a nonzero Zak phase; then, we generalize our findings—addressable in the state-of-the-art cold-atom experiments—to ladders with a higher number of legs.

  19. LOCA analysis of SCWR-M with passive safety system

    Energy Technology Data Exchange (ETDEWEB)

    Liu, X.J., E-mail: xiaojingliu@sjtu.edu.cn [School of Nuclear Science and Engineering, Shanghai Jiao Tong University, 800 Dong Chuan Road, Shanghai 200240 (China); Fu, S.W. [Navy University of Engineering, Wuhan, Hubei (China); Xu, Z.H. [Shanghai Nuclear Engineering Research and Design Institute, Shanghai (China); Yang, Y.H. [School of Nuclear Science and Engineering, Shanghai Jiao Tong University, 800 Dong Chuan Road, Shanghai 200240 (China); Cheng, X. [Institute of Fusion and Nuclear Technology, Karlsruhe Institute of Technology (KIT), Kaiserstr. 12, 76131 Karlsruhe (Germany)

    2013-06-15

    Highlights: • Application of the ATHLET-SC code to the trans-critical analysis for SCWR. • Development of a passive safety system for SCWR-M. • Analysis of hot/cold leg LOCA behaviour with different break size. • Introduction of some mitigation measures for SCWR-M -- Abstract: A new SCWR conceptual design (mixed spectrum supercritical water cooled reactor: SCWR-M) is proposed by Shanghai Jiao Tong University (SJTU). R and D activities covering core design, safety system design and code development of SCWR-M are launched at SJTU. Safety system design and analysis is one of the key tasks during the development of SCWR-M. Considering the current advanced reactor design, a new passive safety system for SCWR-M including isolation cooling system (ICS), accumulator injection system (ACC), gravity driven cooling system (GDCS) and automatic depressurization system (ADS) is proposed. Based on the modified and preliminarily assessed system code ATHLET-SC, loss of coolant accident (LOCA) analysis for hot and cold leg is performed in this paper. Three different break sizes are analyzed to clarify the hot and cold LOCA characteristics of the SCWR-M. The influence of the break location and break size on the safety performance of SCWR-M is also concluded. Several measures to induce the core coolant flow and to mitigate core heating up are also discussed. The results achieved so far demonstrate the feasibility of the proposed passive safety system to keep the SCWR-M core at safety condition during loss of coolant accident.

  20. Statistical Analysis of Hie (Cold Sensation and Hiesho (Cold Disorder in Kampo Clinic

    Directory of Open Access Journals (Sweden)

    Tetsuhiro Yoshino

    2013-01-01

    Full Text Available A cold sensation (hie is common in Japanese women and is an important treatment target in Kampo medicine. Physicians diagnose patients as having hiesho (cold disorder when hie disturbs their daily activity. However, differences between hie and hiesho in men and women are not well described. Hie can be of three types depending on body part where patients feel hie. We aimed to clarify the characteristics of patients with hie and hiesho by analyzing data from new patients seen at the Kampo Clinic at Keio University Hospital between 2008 and 2013. We collected information about patients’ subjective symptoms and their severity using visual analogue scales. Of 4,016 new patients, 2,344 complained about hie and 524 of those were diagnosed with hiesho. Hie was most common in legs/feet and combined with hands or lower back, rather than the whole body. Almost 30% of patients with hie felt upper body heat symptoms like hot flushes. Cold sensation was stronger in hiesho than non-hiesho patients. Patients with hie had more complaints. Men with hiesho had the same distribution of hie and had symptoms similar to women. The results of our study may increase awareness of hiesho and help doctors treat hie and other symptoms.

  1. Experimental study on secondary depressurization action for PWR vessel bottom small break LOCA with HPI failure and gas inflow (ROSA-V/LSTF test SB-PV-03)

    International Nuclear Information System (INIS)

    Suzuki, Mitsuhiro; Takeda, Takeshi; Asaka, Hideaki; Nakamura, Hideo

    2005-06-01

    A small break loss-of-coolant accident (SBLOCA) experiment was conducted at the Large Scale Test Facility (LSTF) of ROSA-V program to study effects of accident management (AM) measures on core cooling, which is important in case of high pressure injection (HPI) system failure during an SBLOCA at a pressurized water reactor (PWR). The LSTF is a full-height and 1/48 volume-scaled facility simulating 4-loop Westinghouse-type PWR (3423 MWt). The experiment, SB-PV-03, simulated a PWR vessel bottom SBLOCA with a rupture of ten instrument-tubes which is equivalent to 0.2% cold leg break. Total HPI failure, non-condensable gas inflow from accumulator injection system (AIS) and operator AM actions on steam generator (SG) secondary depressurization at a rate of -55 K/h and auxiliary feedwater (AFW) supply for 30 minutes were assumed as experiment conditions. It is clarified that the AM actions are effective on primary system depressurization until the end of AIS injection at 1.6 MPa, but thereafter become less effective due to inflow of the non-condensable gas, resulting in delay of low pressure injection (LPI) actuation and whole core heatup under continuous water discharge through the bottom break. The report describes these thermohydraulic phenomena related with transient primary coolant mass and AM actions in addition to estimation of non-condensable gas behavior which affected primary-to-secondary heat transfer. (author)

  2. The Relationship among Leg Strength, Leg Power and Alpine Skiing Success.

    Science.gov (United States)

    Gettman, Larry R.; Huckel, Jack R.

    The purpose of this study was to relate leg strength and power to alpine skiing success as measured by FIS points. Isometric leg strength was represented by the knee extension test described by Clarke. Leg power was measured by the vertical jump test and the Margaria-Kalamen stair run. Results in the strength and power tests were correlated with…

  3. An experimental study on effective depressurization actions for PWR vessel bottom small break LOCA with HPI failure and gas inflow (ROSA-V test SB-PV-04)

    International Nuclear Information System (INIS)

    Suzuki, Mitsuhiro; Takeda, Takeshi; Asaka, Hideaki; Nakamura, Hideo

    2006-03-01

    A small break loss-of-coolant accident (SBLOCA) experiment was conducted at the Large Scale Test Facility (LSTF) of ROSA-V program to study effects of accident management (AM) measures on core cooling, which are important in case of total failure of high pressure injection (HPI) system during an SBLOCA at a pressurized water reactor (PWR). The LSTF is a full-height and 1/48 volume-scaled facility simulating a 4-loop Westing-house-type PWR (3423 MWt). The experiment, SB-PV-04, simulated a PWR vessel bottom SBLOCA with a rupture of ten instrument-tubes which is equivalent to 0.2% cold leg break. It is clarified that AM actions with steam generator (SG) rapid depressurization by fully opening relief valves and auxiliary feedwater supply are effective to avoid core uncovery by actuating the low pressure injection (LPI) system though the primary depressurization is degraded by non-condensable gas inflow to the primary loops from the accumulator injection system. The effective core cooling was established by the rapid depressurization which contributed to preserve larger primary coolant mass than in the previous experiment (SB-PV-03) which was conducted with smaller primary cooling rate of -55 K/h as AM actions. (author)

  4. Assessment of SPACE code for multiple failure accident: 1% Cold Leg Break LOCA with HPSI failure at ATLAS Test Facility

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jong Hyuk; Lee, Seung Wook; Kim, Kyung-Doo [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2016-10-15

    Design extension conditions (DECs) is a popular key issue after the Fukushima accident. In a viewpoint of the reinforcement of the defense in depth concept, a high-risk multiple failure accident should be reconsidered. The target scenario of ATLAS A5.1 test was LSTF (Large Scale Test Facility) SB-CL-32 test, a 1% SBLOCA with total failure of high pressure safety injection (HPSI) system of emergency core cooling system (ECCS) and secondary side depressurization as the accident management (AM) action, as a counterpart test. As the needs to prepare the DEC accident because of a multiple failure of the present NPPs are emphasized, the capability of SPACE code, just like other system analysis code, is required to expand the DEC area. The objectives of this study is to validate the capability of SPACE code for a DEC scenario, which represents multiple failure accident like as a SBLOCA with HPSI fail. Therefore, the ATLAS A5.1 test scenario was chosen. As the needs to prepare the DEC accident because of a multiple failure of operating NPPs are emphasized, the capability of SPACE code is needed to expand the DEC area. So the capability of SPACE code was validated for one of a DEC scenario. The target scenario was selected as the ATLAS A5.1 test, which is a 1% SBLOCA with total failure of HPSI system of ECCS and secondary side depressurization. Through the sensitivity study on discharge coefficient of break flow, the best fit of integrated mass was found. Using the coefficient, the ATLAS A5.1 test was analyzed using the SPACE code. The major thermal hydraulic parameters such as the system pressure, temperatures were compared with the test and have a good agreement. Through the simulation, it was concluded that the SPACE code can effectively simulate one of multiple failure accidents like as SBLOCA with HPSI failure accident.

  5. The one-leg standing radiograph

    OpenAIRE

    Pinsornsak, P.; Naratrikun, K.; Kanitnate, S.; Sangkomkamhang, T.

    2016-01-01

    Objectives The purpose of this study was to compare the joint space width between one-leg and both-legs standing radiographs in order to diagnose a primary osteoarthritis of the knee. Methods Digital radiographs of 100 medial osteoarthritic knees in 50 patients were performed. The patients had undergone one-leg standing anteroposterior (AP) views by standing on the affected leg while a both-legs standing AP view was undertaken while standing on both legs. The severity of the osteoarthritis wa...

  6. Single-leg squats can predict leg alignment in dancers performing ballet movements in "turnout".

    Science.gov (United States)

    Hopper, Luke S; Sato, Nahoko; Weidemann, Andries L

    2016-01-01

    The physical assessments used in dance injury surveillance programs are often adapted from the sports and exercise domain. Bespoke physical assessments may be required for dance, particularly when ballet movements involve "turning out" or external rotation of the legs beyond that typically used in sports. This study evaluated the ability of the traditional single-leg squat to predict the leg alignment of dancers performing ballet movements with turnout. Three-dimensional kinematic data of dancers performing the single-leg squat and five ballet movements were recorded and analyzed. Reduction of the three-dimensional data into a one-dimensional variable incorporating the ankle, knee, and hip joint center positions provided the strongest predictive model between the single-leg squat and the ballet movements. The single-leg squat can predict leg alignment in dancers performing ballet movements, even in "turned out" postures. Clinicians should pay careful attention to observational positioning and rating criteria when assessing dancers performing the single-leg squat.

  7. Investigation of Loop Seal Clearing Phenomena for the ATLAS SBLOCA Long Term Cooling Test using TRACE and MARS-KS

    Energy Technology Data Exchange (ETDEWEB)

    Hwang, Min Jeong; Park, M. H.; Marigomen Ralph; Sim, S. K. [Environment and Energy Technology, Daejeon (Korea, Republic of)

    2016-10-15

    During Design Certificate(DC) review of the APR1400, USNRC raised a long term cooling safety issue on the effect of loop seal clearing during cold leg Small Break Loss Of Coolant Accident(SBLOCA) due to relatively deep cross-over loop compared to the US PWRs. The objective of this study is thus to investigate the loop seal clearing phenomena during cold leg slot break SBLOCA long term cooling and resolve the safety issue on the SBLOCA long term cooling related to the APR1400 DC. TRACE and MARS-KS were used to predict the test results and to perform sensitivity studies for the SBLOCA loop seal clearing phenomena. The calculation shows that the TRACE code well predict the sequence of Test LTC-CL-04R. However, compared to the experiment, the TRACE over predicts the primary pressure due to smaller break flow prediction. MARS-KS well predicts major thermal hydraulic parameters during the transient with reasonable agreement. MARS-KS better predicts ATLAS LTC-CL-04R test data with a good agreement than the TRACE due to better prediction of the break flow. Overall, compared to the experiment, the TRACE and MARS-KS Codes show a discrepancy in predicting the loop seal clearing and reformation time. Both TRACE and MARS-KS correctly predicts core water level and fuel cladding temperatures. From this study, it can be said that even though APR1400 cross-over leg design has slightly deeper loop seals, the effect on the safety of the SBLOCA long term cooling is minimal compared to the SBLOCA cladding failure criteria. Further study on the SBLOCA loop seal clearing phenomena is needed.

  8. Classification of a Supersolid: Trial Wavefunctions, Symmetry Breakings and Excitation Spectra

    Science.gov (United States)

    Chen, Yu; Ye, Jinwu; Tian, Guangshan

    2012-11-01

    A state of matter is characterized by its symmetry breaking and elementary excitations. A supersolid is a state which breaks both translational symmetry and internal U(1) symmetry. Here, we review some past and recent works in phenomenological Ginsburg-Landau theories, ground state trial wavefunctions and microscopic numerical calculations. We also write down a new effective supersolid Hamiltonian on a lattice. The eigenstates of the Hamiltonian contains both the ground state wavefunction and all the excited states (supersolidon) wavefunctions. We contrast various kinds of supersolids in both continuous systems and on lattices, both condensed matter and cold atom systems. We provide additional new insights in studying their order parameters, symmetry breaking patterns, the excitation spectra and detection methods.

  9. Comparative Experiments to Assess the Effects of Accumulator Nitrogen Injection on Passive Core Cooling During Small Break LOCA

    Directory of Open Access Journals (Sweden)

    Li Yuquan

    2017-02-01

    Full Text Available The accumulator is a passive safety injection device for emergency core cooling systems. As an important safety feature for providing a high-speed injection flow to the core by compressed nitrogen gas pressure during a loss-of-coolant accident (LOCA, the accumulator injects its precharged nitrogen into the system after its coolant has been emptied. Attention has been drawn to the possible negative effects caused by such a nitrogen injection in passive safety nuclear power plants. Although some experimental work on the nitrogen injection has been done, there have been no comparative tests in which the effects on the system responses and the core safety have been clearly assessed. In this study, a new thermal hydraulic integral test facility—the advanced core-cooling mechanism experiment (ACME—was designed and constructed to support the CAP1400 safety review. The ACME test facility was used to study the nitrogen injection effects on the system responses to the small break loss-of-coolant accident LOCA (SBLOCA transient. Two comparison test groups—a 2-inch cold leg break and a double-ended direct-vessel-injection (DEDVI line break—were conducted. Each group consists of a nitrogen injection test and a nitrogen isolation comparison test with the same break conditions. To assess the nitrogen injection effects, the experimental data that are representative of the system responses and the core safety were compared and analyzed. The results of the comparison show that the effects of nitrogen injection on system responses and core safety are significantly different between the 2-inch and DEDVI breaks. The mechanisms of the different effects on the transient were also investigated. The amount of nitrogen injected, along with its heat absorption, was likewise evaluated in order to assess its effect on the system depressurization process. The results of the comparison and analyses in this study are important for recognizing and understanding the

  10. Comparative experiments to assess the effects of accumulator nitrogen injection on passive core cooling during small break LOCA

    Energy Technology Data Exchange (ETDEWEB)

    Li, YuQuan; Hao, Botao; Zhong, Jia; Wan Nam [State Nuclear Power Technology R and D Center, South Park, Beijing Future Science and Technology City, Beijing (China)

    2017-02-15

    The accumulator is a passive safety injection device for emergency core cooling systems. As an important safety feature for providing a high-speed injection flow to the core by compressed nitrogen gas pressure during a loss-of-coolant accident (LOCA), the accumulator injects its precharged nitrogen into the system after its coolant has been emptied. Attention has been drawn to the possible negative effects caused by such a nitrogen injection in passive safety nuclear power plants. Although some experimental work on the nitrogen injection has been done, there have been no comparative tests in which the effects on the system responses and the core safety have been clearly assessed. In this study, a new thermal hydraulic integral test facility—the advanced core-cooling mechanism experiment (ACME)—was designed and constructed to support the CAP1400 safety review. The ACME test facility was used to study the nitrogen injection effects on the system responses to the small break loss-of-coolant accident LOCA (SBLOCA) transient. Two comparison test groups—a 2-inch cold leg break and a double-ended direct-vessel-injection (DEDVI) line break—were conducted. Each group consists of a nitrogen injection test and a nitrogen isolation comparison test with the same break conditions. To assess the nitrogen injection effects, the experimental data that are representative of the system responses and the core safety were compared and analyzed. The results of the comparison show that the effects of nitrogen injection on system responses and core safety are significantly different between the 2-inch and DEDVI breaks. The mechanisms of the different effects on the transient were also investigated. The amount of nitrogen injected, along with its heat absorption, was likewise evaluated in order to assess its effect on the system depressurization process. The results of the comparison and analyses in this study are important for recognizing and understanding the potential negative

  11. Foot, leg, and ankle swelling

    Science.gov (United States)

    Swelling of the ankles - feet - legs; Ankle swelling; Foot swelling; Leg swelling; Edema - peripheral; Peripheral edema ... Foot, leg, and ankle swelling is common when the person also: Is overweight Has a blood clot in the leg Is older Has ...

  12. Effects of water temperature on breeding phenology, growth and timing of metamorphosis of foothill yellow-legged frogs (Rana boylii) on the mainstem and selected tributaries of California's Trinity River - 2004-2009.

    Science.gov (United States)

    Clara Wheeler; James Bettaso; Donald Ashton; Hartwell Welsh

    2013-01-01

    The cold temperatures maintained in the Trinity River are beneficial to fish but may be problematic for foothill yellow-legged frogs. We examined the timing of breeding, reproductive output, and growth and development of tadpoles for populations of foothill yellow-legged frogs on the mainstem and six tributaries of the Trinity River. On the colder mainstem, onset of...

  13. Effect of cold indoor environment on physical performance of older women living in the community.

    Science.gov (United States)

    Lindemann, Ulrich; Oksa, Juha; Skelton, Dawn A; Beyer, Nina; Klenk, Jochen; Zscheile, Julia; Becker, Clemens

    2014-07-01

    the effects of cold on older persons' body and mind are not well documented, but with an increased number of older people with decreasing physical performance, these possible effects need to be understood. to investigate the effect of cold indoor environment on physical performance of older women. cross-sectional experimental study with two test conditions. movement laboratory in a climate chamber. eighty-eight community-dwelling, cognitively unimpaired older women (mean age 78 years). participants were exposed to moderately cold (15°C) and warm/normal (25°C) temperature in a climate chamber in random order with an interval of 1 week. The assessment protocol included leg extensor power (Nottingham Power Rig), sit-to-stand performance velocity (linear encoder), gait speed, walk-ratio (i.e. step length/cadence on an instrumented walk way), maximal quadriceps and hand grip strength. physical performance was lower in 15°C room temperature compared with 25°C room temperature for leg extensor power (P environment decreased important physical performance measures necessary for independent living. © The Author 2014. Published by Oxford University Press on behalf of the British Geriatrics Society. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  14. Effects of moist cold stratification on germination, plant growth regulators, metabolites and embryo ultrastructure in seeds of Acer morrisonense (Sapindaceae).

    Science.gov (United States)

    Chen, Shun-Ying; Chou, Shih-Han; Tsai, Ching-Chu; Hsu, Wen-Yu; Baskin, Carol C; Baskin, Jerry M; Chien, Ching-Te; Kuo-Huang, Ling-Long

    2015-09-01

    Breaking of seed dormancy by moist cold stratification involves complex interactions in cells. To assess the effect of moist cold stratification on dormancy break in seeds of Acer morrisonense, we monitored percentages and rates of germination and changes in plant growth regulators, sugars, amino acids and embryo ultrastructure after various periods of cold stratification. Fresh seeds incubated at 25/15 °C for 24 weeks germinated to 61%, while those cold stratified at 5 °C for 12 weeks germinated to 87% in 1 week. Neither exogenous GA3 nor GA4 pretreatment significantly increased final seed germination percentage. Total ABA content of seeds cold stratified for 12 weeks was reduced about 3.3-fold, to a concentration similar to that in germinated seeds (radicle emergence). Endogenous GA3 and GA7 were detected in 8-week and 12-week cold stratified seeds but not in fresh seeds. Numerous protein and lipid bodies were present in the plumule, first true leaves and cotyledons of fresh seeds. Protein and lipid bodies decreased greatly during cold stratification, and concentrations of total soluble sugars and amino acids increased. The major non-polar sugars in fresh seeds were sucrose and fructose, but sucrose increased and fructose decreased significantly during cold stratification. The major free amino acids were proline and tryptophan in fresh seeds, and proline increased and tryptophan decreased during cold stratification. Thus, as dormancy break occurs during cold stratification seeds of A. morrisonense undergo changes in plant growth regulators, proteins, lipids, sugars, amino acids and cell ultrastructure. Copyright © 2015 Elsevier Masson SAS. All rights reserved.

  15. Comprehensive safety analysis code system for nuclear fusion reactors III: Ex-vessel LOCA analyses considering passive safety

    International Nuclear Information System (INIS)

    Honda, T.; Okazaki, T.; Maki, K.; Uda, T.; Seki, Y.; Aoki, I.; Kunugi, T.

    1996-01-01

    Ex-vessel loss-of-coolant accidents (LOCAs) in a fusion reactor have been analyzed to investigate the possibility of passive plasma shutdown. For this purpose, a hybrid code of the plasma dynamics and thermal characteristics of the reactor structures, which has been modified to include the impurity emission from plasma-facing components (PFCs), has been developed. Ex-vessel LOCAs of the cooling system during the ignition operation in the International Thermonuclear Experimental Reactor (ITER), in which graphite PFCs were employed in conceptual design activity, were assumed. When double-ended break occurs at the cold leg of the divertor cooling system, the copper cooling tube begins to melt within 3 s after the LOCA, even though the plasma is passively shut down at nearly 4 s. An active plasma shutdown system will be needed for such rapid transient accidents. On the other hand, when a small (1%) break LOCA occurs there, the plasma is passively shut down at nearly 36 s, which happens before the copper cooling tube begins to melt. When the double-ended break LOCA occurs at the cold leg of the first-wall cooling system, there is enough time (nearly 100 s) to shut down the plasma with a controllable method before the reactor structures are damaged. 21 refs., 8 figs

  16. Single-leg squats can predict leg alignment in dancers performing ballet movements in “turnout”

    Science.gov (United States)

    Hopper, Luke S; Sato, Nahoko; Weidemann, Andries L

    2016-01-01

    The physical assessments used in dance injury surveillance programs are often adapted from the sports and exercise domain. Bespoke physical assessments may be required for dance, particularly when ballet movements involve “turning out” or external rotation of the legs beyond that typically used in sports. This study evaluated the ability of the traditional single-leg squat to predict the leg alignment of dancers performing ballet movements with turnout. Three-dimensional kinematic data of dancers performing the single-leg squat and five ballet movements were recorded and analyzed. Reduction of the three-dimensional data into a one-dimensional variable incorporating the ankle, knee, and hip joint center positions provided the strongest predictive model between the single-leg squat and the ballet movements. The single-leg squat can predict leg alignment in dancers performing ballet movements, even in “turned out” postures. Clinicians should pay careful attention to observational positioning and rating criteria when assessing dancers performing the single-leg squat. PMID:27895518

  17. Break a Leg

    Science.gov (United States)

    Gisolfi, Peter A.

    2005-01-01

    The basic dilemma in creating performance spaces in secondary schools is that such spaces often must serve multiple functions. Ideally, there should be three different spaces: one to present dramas; another for musical performances; and a third for assemblies--lectures, movies, political and community events. Often, the unsatisfactory solution to…

  18. Genetic parameters for claw and leg health, foot and leg conformation, and locomotion in Danish Holsteins

    DEFF Research Database (Denmark)

    Laursen, M. V.; Boelling, D.; Mark, Thomas

    2009-01-01

    was defined as absence of hock infection, swollen hock, and bruising. The potential indicators were locomotion and foot and leg conformation, represented by rear leg side view, rear leg rear view, foot angle, and apparent hock quality and bone structure. The study was conducted using records from 429......,877 Danish Holstein cows in first lactation. Binary health traits were divided into 3 subcategories: claw health, leg health, and absence of all claw and leg disorders. Genetic (r(g)) and phenotypic correlations were estimated using a bivariate linear sire model and REML. Estimated heritabilities were 0.......01 for all 3 combined claw and leg health traits (on the observed binary scale), 0.09 for locomotion, 0.14 for rear leg rear view, 0.19 for rear leg side view, 0.13 for foot angle, 0.22 for apparent hock quality, and 0.27 for apparent bone structure. Heritabilities were 0.06 and 0.01 for claw health and leg...

  19. Setting parameters in the cold chain

    Directory of Open Access Journals (Sweden)

    Victoria Rodríguez

    2011-12-01

    Full Text Available Breaks in the cold chain are important economic losses in food and pharmaceutical companies. Many of the failures in the cold chain are due to improper adjustment of equipment parameters such as setting the parameters for theoretical conditions, without a corresponding check in normal operation. The companies that transport refrigeratedproducts must be able to adjust the parameters of the equipment in an easy and quick to adapt their functioning to changing environmental conditions. This article presents the results of a study carried out with a food distribution company. The main objective of the study is to verify the effectiveness of Six Sigma as a methodological toolto adjust the equipment in the cold chain. The second objective is more speciÞ c and is to study the impact of: reducing the volume of storage in the truck, the initial temperature of the storage areain the truck and the frequency of defrost in the transport of refrigerated products.

  20. Stable walking with asymmetric legs

    International Nuclear Information System (INIS)

    Merker, Andreas; Rummel, Juergen; Seyfarth, Andre

    2011-01-01

    Asymmetric leg function is often an undesired side-effect in artificial legged systems and may reflect functional deficits or variations in the mechanical construction. It can also be found in legged locomotion in humans and animals such as after an accident or in specific gait patterns. So far, it is not clear to what extent differences in the leg function of contralateral limbs can be tolerated during walking or running. Here, we address this issue using a bipedal spring-mass model for simulating walking with compliant legs. With the help of the model, we show that considerable differences between contralateral legs can be tolerated and may even provide advantages to the robustness of the system dynamics. A better understanding of the mechanisms and potential benefits of asymmetric leg operation may help to guide the development of artificial limbs or the design novel therapeutic concepts and rehabilitation strategies.

  1. LOFT/LP-02-6, Loss of Fluid Test, 1. OECD Large Break Experiment

    International Nuclear Information System (INIS)

    1989-01-01

    1 - Description of test facility: The LOFT Integral Test Facility is a scale model of a LPWR. The intent of the facility is to model the nuclear, thermal-hydraulic phenomena which would take place in a LPWR during a LOCA. The general philosophy in scaling coolant volumes and flow areas in LOFT was to use the ratio of the LOFT core [50 MW(t)] to a typical LPWR core [3000 MW(t)]. For some components, this factor is not applied; however, it is used as extensively as practical. In general, components used in LOFT are similar in design to those of a LPWR. Because of scaling and component design, the LOFT LOCA is expected to closely model a LPWR LOCA. 2 - Description of test: The fourth OECD LOFT experiment was conducted on 3 October 1983. This was the first OECD LOFT large break experiment. The initial and boundary conditions were chosen to be representative of USNRC licensing limits for commercial PWRs. This included loss of off-site power coincident with LOCA initiation. This experiment included the first use in LOFT of pressurized fuel rods in the center bundle. The experiment was initiated by opening the quick-opening blow-down valves in the broken hot and cold legs. 3 - Experimental limitations or shortcomings: Short core and steam generator, excessive core bypass, other scaling compromises, and lack of adequate measurements in certain areas

  2. Analysis of Post-LOCA Core Inlet Blockage to Evaluate In-vessel Downstream Effect in APR1400

    International Nuclear Information System (INIS)

    Bang, Young Seok

    2015-01-01

    The method was developed to have a conservatism to cover the uncertainty of analysis and the acceptance is judged by the representative bounding estimation. However, the important safety parameters such as the available driving head need to be confirmed by the plant specific calculation. Also an interaction between the debris induced head loss and the core flow rate needs to be explained because the head loss induced by debris in actual condition may reduce the core inflow rate faster. To confirm the safety parameters, in this study, thermal-hydraulic response considering the core inlet blockage (CIB) by debris during LTCC process following a double-ended guillotine break of cold leg (CLB), one of hot leg (HLB) and one of intermediate leg (ILB) of the APR1400 were calculated, respectively. MARS-KS 1.3 code has been used. The CIB has been modeled by the closure of valves to the core in exponential manner with time to observe the behavior near the complete blockage. To understand the effect of core inlet blockage (CIB) during a long term core cooling (LTCC) phase following a loss-of-coolant accident (LOCA) in the light of in-vessel downstream effect (IDE) of Generic Safety Issue (GSI) 191, double-ended guillotine break of hot leg (HLB), one of cold leg (CLB) and one of intermediate leg (ILB) were calculated, respectively. And the important safety parameters such as the available driving head and the head loss due to debris were calculated using MARS-KS code and discussed in comparison with the WCAP method. As a result, a little delayed heatup behavior of the fuel cladding was found for all the cases, which due to the redistribution of flow within the core after blockage

  3. Analysis of Post-LOCA Core Inlet Blockage to Evaluate In-vessel Downstream Effect in APR1400

    Energy Technology Data Exchange (ETDEWEB)

    Bang, Young Seok [Korea Institute of Nuclear Safety, Daejeon (Korea, Republic of)

    2015-10-15

    The method was developed to have a conservatism to cover the uncertainty of analysis and the acceptance is judged by the representative bounding estimation. However, the important safety parameters such as the available driving head need to be confirmed by the plant specific calculation. Also an interaction between the debris induced head loss and the core flow rate needs to be explained because the head loss induced by debris in actual condition may reduce the core inflow rate faster. To confirm the safety parameters, in this study, thermal-hydraulic response considering the core inlet blockage (CIB) by debris during LTCC process following a double-ended guillotine break of cold leg (CLB), one of hot leg (HLB) and one of intermediate leg (ILB) of the APR1400 were calculated, respectively. MARS-KS 1.3 code has been used. The CIB has been modeled by the closure of valves to the core in exponential manner with time to observe the behavior near the complete blockage. To understand the effect of core inlet blockage (CIB) during a long term core cooling (LTCC) phase following a loss-of-coolant accident (LOCA) in the light of in-vessel downstream effect (IDE) of Generic Safety Issue (GSI) 191, double-ended guillotine break of hot leg (HLB), one of cold leg (CLB) and one of intermediate leg (ILB) were calculated, respectively. And the important safety parameters such as the available driving head and the head loss due to debris were calculated using MARS-KS code and discussed in comparison with the WCAP method. As a result, a little delayed heatup behavior of the fuel cladding was found for all the cases, which due to the redistribution of flow within the core after blockage.

  4. Venous leg ulcers

    Science.gov (United States)

    2008-01-01

    Introduction Leg ulcers usually occur secondary to venous reflux or obstruction, but 20% of people with leg ulcers have arterial disease, with or without venous disorders. Between 1.5 and 3.0/1000 people have active leg ulcers. Prevalence increases with age to about 20/1000 in people aged over 80 years. Methods and outcomes We conducted a systematic review and aimed to answer the following clinical questions: What are the effects of standard treatments, adjuvant treatments, and organisational interventions for venous leg ulcers? What are the effects of interventions to prevent recurrence of venous leg ulcers? We searched: Medline, Embase, The Cochrane Library, and other important databases up to September 2007 (BMJ Clinical Evidence reviews are updated periodically, please check our website for the most up-to-date version of this review). We included harms alerts from relevant organisations such as the US Food and Drug Administration (FDA) and the UK Medicines and Healthcare products Regulatory Agency (MHRA). Results We found 80 systematic reviews, RCTs, or observational studies that met our inclusion criteria. We performed a GRADE evaluation of the quality of evidence for interventions. Conclusions In this systematic review we present information relating to the effectiveness and safety of the following interventions: compression bandages and stockings, cultured allogenic (single or bilayer) skin replacement, debriding agents, dressings (cellulose, collagen, film, foam, hyaluronic acid-derived, semi-occlusive alginate), hydrocolloid (occlusive) dressings in the presence of compression, intermittent pneumatic compression, intravenous prostaglandin E1, larval therapy, laser treatment (low-level), leg ulcer clinics, multilayer elastic system, multilayer elastomeric (or non-elastomeric) high-compression regimens or bandages, oral treatments (aspirin, flavonoids, pentoxifylline, rutosides, stanozolol, sulodexide, thromboxane alpha2 antagonists, zinc), peri

  5. Cold weather effects on Dresden Unit 1

    Energy Technology Data Exchange (ETDEWEB)

    Anagnostopoulos, H. [Commonwealth Edison Co., Morris, IL (United States)

    1995-03-01

    Dresden Unit 1 is in the final stages of a decommissioning effort directed at preparing the unit to enter a SAFSTOR status. Following an extended sub-zero cold wave, about 55,000 gallons of water were discovered in the lowest elevation of the spherical reactor enclosure. Cold weather had caused the freezing and breaking of several service water lines that had not been completely isolated. Two days later, at a regularly scheduled decommissioning meeting, the event was communicated to the decommissioning team, who quickly recognized the potential for freezing of a 42 inches diameter Fuel Transfer Tube that connects the sphere to the Spent Fuel Pool. The team directed that the pool gates between the adjacent Spent Fuel Pool and the Fuel Transfer Pool be installed, and a portable source of heat was installed on the Fuel Transfer Tube. It was later determined that, with the fuel pool gates removed, and with a worst case freeze break at the 502 elevation on the Fuel Transfer Tube (in the Sphere), the fuel in the Spent Fuel Pool could be uncovered to a level 3 below the top of active fuel.

  6. ROSA-II test data report, 11

    International Nuclear Information System (INIS)

    1978-02-01

    Results of the ROSA-II tests simulating a loss-of-coolant accident (LOCA) and effects of an emergency core cooling system (ECCS) in a pressurized water reactor (PWR) are presented including the test conditions and interpretations of the data in test runs 327,328,329 and 330. Each test was performed with large double-ended hot leg break and effect of the break area distribution (break diameter are 25.0 mm at one end and 37.5 mm at the other end of break) and of pump circulation upon coolant flow in the core were studied. The following are the results: In the case of a smaller break on the steam generator side, core cooling was achieved due to upward coolant flow in the core and early reflooding by ACC water injected into the cold leg. In the case of a smaller break area on the vessel side, on the other hand, coolant flow in the core was stagnant and the heater rods were mostly exposed to steam, so that core cooling was not as good. Effect of the coolant circulation by acting pump on the core cooling during a blowdown was not significant except that in a steam generator side small break the core cooling was improved. (auth.)

  7. Sensitivity of break-flow-partition on the containment pressure and temperature

    International Nuclear Information System (INIS)

    Kwon, Young Min; Song, Jin Ho; Lee, Sang Yong

    1994-01-01

    For the case of RCS blowdown into the vapor region of a containment at low pressure, the blowdown mixture will start to boil at the containment pressure and liquid will separate from the flow near the break location. The flashed steam is added to the containment atmosphere and liquid is falled to the sump. Analytically, the break flow can be divided into steam and liquid in a number of ways. Discussed in this study is three partition models and Instantaneous Mixing(IM) Model employed in different containment analysis computer codes. IM model is employed in the CONTRANS code developed by ABB-CE for containment thermodynamic analysis. The various partition models were applied to the double ended discharge leg slot break (DEDLS) LOCA which is containment design base accident (CDBA) for Ulchin 3 and 4 PSAR. It was shown that IM model is the most conservative for containment design pressure analysis. Results of the CONTRANS analyses are compared with those of UCN PSAR for which CONTEMPT-LT code was used

  8. Verification of the code ATHLET by post-test analysis of two experiments performed at the CCTF integral test facility

    International Nuclear Information System (INIS)

    Krepper, E.; Schaefer, F.

    2001-03-01

    In the framework of the external validation of the thermohydraulic code ATHLET Mod 1.2 Cycle C, which has been developed by the GRS, post test analyses of two experiments were done, which were performed at the japanese test facility CCTF. The test facility CCTF is a 1:25 volume-scaled model of a 1000 MW pressurized water reactor. The tests simulate a double end break in the cold leg of the PWR with ECC injection into the cold leg and with combined ECC injection into the hot and cold legs. The evaluation of the calculated results shows, that the main phenomena can be calculated in a good agreement with the experiment. Especially the behaviour of the quench front and the core cooling are calculated very well. Applying a two-channel representation of the reactor model the radial behaviour of the quench front could be reproduced. Deviations between calculations and experiment can be observed simulating the emergency injection in the beginning of the transient. Very high condensation rates were calculated and the pressure decrease in this phase of the transient is overestimated. Besides that, the pressurization due to evaporation in the refill phase is underestimated by ATHLET. (orig.) [de

  9. Lyden-af-Leg

    DEFF Research Database (Denmark)

    Toft, Herdis

    Præsentation af seniorforsker-projekt Lyden-af-Leg i et traderingsperspektiv og med indledende fokus på YouTube som traderings-platform.......Præsentation af seniorforsker-projekt Lyden-af-Leg i et traderingsperspektiv og med indledende fokus på YouTube som traderings-platform....

  10. Break the Kill Chain, Not the Budget: How to Avoid U.S. Strategic Retrenchment

    Science.gov (United States)

    2016-06-10

    mass quantities. The United States maintained a Cold War offset strategy focused on technology and kill chain annihilation with an understanding of...Annihilating the kill chain with advanced instruments of war is more the norm than the exception in the post- Cold War era U.S. military. The U.S. Air...Masters Thesis 3. DATES COVERED (From - To) 27-07-2015 to 10-06-2016 4. TITLE AND SUBTITLE 5a. CONTRACT NUMBER BREAK THE KILL CHAIN

  11. Best estimate prediction for LOFT nuclear experiment L3-2

    International Nuclear Information System (INIS)

    Kee, E.J.; Shinko, M.S.; Grush, W.H.; Condie, K.G.

    1980-02-01

    Comprehensive analyses using both the RELAP4 and the RELAP5 computer codes were performed to predict the LOFT transient thermal-hydraulic response for nuclear Loss-of-Coolant Experiment L3-2 to be performed in the Loss-of-Fluid Test (LOFT) facility. The LOFT experiment will simulate a small break in one of the cold legs of a large four-loop pressurized water reactor and will be conducted with the LOFT reactor operating at 50 MW. The break in LOCE L3-2 is sized to cause the break flow to be approximately equal to the high-pressure injection system flow at an intermediate pressure of approximately 7.6 MPa

  12. Increasing trunk flexion transforms human leg function into that of birds despite different leg morphology.

    Science.gov (United States)

    Aminiaghdam, Soran; Rode, Christian; Müller, Roy; Blickhan, Reinhard

    2017-02-01

    Pronograde trunk orientation in small birds causes prominent intra-limb asymmetries in the leg function. As yet, it is not clear whether these asymmetries induced by the trunk reflect general constraints on the leg function regardless of the specific leg architecture or size of the species. To address this, we instructed 12 human volunteers to walk at a self-selected velocity with four postures: regular erect, or with 30 deg, 50 deg and maximal trunk flexion. In addition, we simulated the axial leg force (along the line connecting hip and centre of pressure) using two simple models: spring and damper in series, and parallel spring and damper. As trunk flexion increases, lower limb joints become more flexed during stance. Similar to birds, the associated posterior shift of the hip relative to the centre of mass leads to a shorter leg at toe-off than at touchdown, and to a flatter angle of attack and a steeper leg angle at toe-off. Furthermore, walking with maximal trunk flexion induces right-skewed vertical and horizontal ground reaction force profiles comparable to those in birds. Interestingly, the spring and damper in series model provides a superior prediction of the axial leg force across trunk-flexed gaits compared with the parallel spring and damper model; in regular erect gait, the damper does not substantially improve the reproduction of the human axial leg force. In conclusion, mimicking the pronograde locomotion of birds by bending the trunk forward in humans causes a leg function similar to that of birds despite the different morphology of the segmented legs. © 2017. Published by The Company of Biologists Ltd.

  13. Single-leg squats can predict leg alignment in dancers performing ballet movements in “turnout”

    Directory of Open Access Journals (Sweden)

    Hopper LS

    2016-11-01

    Full Text Available Luke S Hopper,1 Nahoko Sato,2 Andries L Weidemann1 1Western Australian Academy of Performing Arts, Edith Cowan University, Mt Lawley, WA, Australia; 2Department of Physical Therapy, Nagoya Gakuin University, Seto, Japan Abstract: The physical assessments used in dance injury surveillance programs are often adapted from the sports and exercise domain. Bespoke physical assessments may be required for dance, particularly when ballet movements involve “turning out” or external rotation of the legs beyond that typically used in sports. This study evaluated the ability of the traditional single-leg squat to predict the leg alignment of dancers performing ballet movements with turnout. Three-dimensional kinematic data of dancers performing the single-leg squat and five ballet movements were recorded and analyzed. Reduction of the three-dimensional data into a one-dimensional variable incorporating the ankle, knee, and hip joint center positions provided the strongest predictive model between the single-leg squat and the ballet movements. The single-leg squat can predict leg alignment in dancers performing ballet movements, even in “turned out” postures. Clinicians should pay careful attention to observational positioning and rating criteria when assessing dancers performing the single-leg squat. Keywords: injury, motion capture, clinical assessment

  14. Leg Injuries and Disorders

    Science.gov (United States)

    ... are important for motion and standing. Playing sports, running, falling, or having an accident can damage your legs. Common leg injuries include sprains and strains, joint dislocations, and fractures. ...

  15. Spontaneous De-Icing Phenomena on Extremely Cold Surfaces

    Science.gov (United States)

    Song, Dong; Choi, Chang-Hwan

    2017-11-01

    Freezing of droplets on cold surfaces is universal phenomenon, while the mechanisms are still inadequately understood. Here we report spontaneous de-icing phenomena of an impacting droplet which occur on extreme cold surfaces. When a droplet impacts on cold surfaces lower than -80°, it takes more than two times longer for the droplet to freeze than the ones at -50°. Moreover, the frozen droplet below -80° breaks up into several large parts spontaneously in the end. When a droplet impacts on the extreme cold surfaces, evaporation and condensation occur immediately as the droplet approaches the substrate. A thick layer of frost forms between the droplet and substrate, decreasing the contact area of the droplet with substrate. It leads to impede the heat transfer and hence extends the freezing time significantly. On the extremely cold substrate, the droplet freezes from the center to the edge area, in contrast to a typical case freezing from the bottom to the top. This novel from-center-to-edge freezing process changes the internal tension of the frozen droplet and results in the instantaneous breakup and release eventually, which can be taken advantage of for effective deicing mechanisms.

  16. A study on effective system depressurization during a PWR vessel bottom break LOCA with HPI failure and gas inflow prevention. ROSA-V/LSTF test SB-PV-05

    International Nuclear Information System (INIS)

    Suzuki, Mitsuhiro; Takeda, Takeshi; Asaka, Hideaki; Nakamura, Hideo

    2006-11-01

    A small break loss-of-coolant accident (SBLOCA) experiment was conducted at the Large Scale Test Facility (LSTF) of ROSA-V program to study effects of accident management (AM) measures on core cooling, which are important in case of total failure of high pressure injection (HPI) system during an SBLOCA at a pressurized water reactor (PWR). The LSTF is a full-height and 1/48 volume-scaled facility simulating a 4-loop Westinghouse-type PWR (3423 MWt). The experiment, SB-PV-05, simulated a PWR vessel bottom SBLOCA with a rupture of nine instrument tubes, which is equivalent to 0.18% cold leg break. It is clarified that AM actions with steam generator (SG) depressurization to achieve a primary loop cooling rate at -55 K/h and auxiliary feedwater supply for 30 minutes are effective to avoid core uncovery by actuating the low pressure injection (LPI) system. It is also shown through the comparison with the previous experiment of SB-PV-03 that prevention of non-condensable gas inflow from the accumulator injection system (AIS) is very important to actuate the LPI to achieve adequate core cooling. This report presents experiment results of SB-PV-05 in detail and shows the effects of gas inflow prevention on core cooling through the estimation of primary coolant mass and energy balance in the primary system. (author)

  17. Long-term recovery of pressurized water reactors following a large break loss-of-coolant accident

    International Nuclear Information System (INIS)

    Fletcher, C.D.; Callow, R.A.

    1989-01-01

    The USNRC recently identified a possible safety concern for PWR's. Following the reflood phase of a large break loss-of-coolant accident, long-term cooling of the reactor core may not be ensured. Specifically, the concern is that, for a pump discharge cold leg break, the loop seals in the reactor coolant pump suction piping will refill with liquid and the post-reflood steam production may depress the liquid levels in the downflow sides of the loop seals. A loop seal depression would cause a corresponding depression of the core liquid levels and possibly a fuel rod heatup in the upper core region. This paper is intended as an introduction of the safety issue that: 1) describes the important aspects of the problem, 2) provides an initial analysis of the consequences, and 3) discusses ongoing work in this area. Because the elevation of the loop seals is near the mid-core elevation in plants of WE design, the concern is greatest for those plants. There is less concern for most plants of CE design, and likely no concern for plants of BW design. This issue was addressed by employing both steady-state and transient systems analysis approaches. Two approaches were used because of uncertainties regarding actual reactor coolant system behavior during the post-reflood period. The steady-state approach involved the development and application of a simple computer program to investigate reactor coolant system behavior assuming quiescent post-reflood conditions. The transient systems approach involved investigating this behavior using the RELAP5/MOD2 computer code and a comprehensive RELAP5 model of a WE PWR. The steady-state analysis indicated only a moderate fuel rod heatup is possible. The transient systems analysis indicated boiling and condensation-induced flow oscillations are sufficient to prevent fuel rod heatup. Analysis uncertainties are discussed. (orig./HP)

  18. Exertional rhabdomyolysis in a collegiate american football player after preventive cold-water immersion: a case report.

    Science.gov (United States)

    Kahanov, Leamor; Eberman, Lindsey E; Wasik, Mitchell; Alvey, Thurman

    2012-01-01

    To describe a case of exertional rhabdomyolysis in a collegiate American football player after preventive coldwater immersion. A healthy man (19 years old) participated in full-contact football practice followed by conditioning (2.5 hours). After practice, he entered a coach-mandated postpractice cold-water immersion and had no signs of heat illness before developing leg cramps, for which he presented to the athletic training staff. After 10 minutes of repeated stretching, massage, and replacement of electrolyte-filled fluids, he was transported to the emergency room. Laboratory tests indicated a creatine kinase (CK) level of 2545 IU/L (normal range, 45-260 IU/L), CK-myoglobin fraction of 8.5 ng/mL (normal football practice as tolerated. Two months after the incident, his CK level remained high (1900 IU/L). The athlete demonstrated no signs of heat illness upon entering the cold-water immersion but experienced severe leg cramping after immersion, resulting in a diagnosis of exertional rhabdomyolysis. Previously described cases have not linked cold-water immersion with the pathogenesis of rhabdomyolysis. In this football player, CK levels appeared to be a poor indicator of rhabdomyolysis. Our patient demonstrated no other signs of the illness weeks after the incident, yet his elevated CK levels persisted. Cold-water immersion immediately after exercise should be monitored by the athletic training staff and may not be appropriate to prevent muscle damage, given the lack of supporting evidence.

  19. ROSA-II test data report, 10

    International Nuclear Information System (INIS)

    1977-12-01

    Results of the ROSA-II test simulating a loss-of coolant accident (LOCA) in a light water reactor (LWR) are presented, including the test conditions and interpretation of the phenomena for test runs 415, 417, 421 and 422. Even in small break at the cold leg, the core is exposed to void and the temperature rises. In small break of the hot leg, however, core cooling keeps without temperature rise, because there still remains much residual water and upward core flow exists. Direct effect of the HPCI on the depressurization rate is small, but it increases the accumulator injection rate, leading to early core reflooding and early core cooling from upward. Effects of the secondary system depressurization are increase of depressurization and discharge rates of the primary loop, which results in early initiation of the accumulator injection and core reflooding. (auth.)

  20. HISTOMORPHOMETRIC ANALYSIS OF THE KNEE ARTICULAR CARTILAGE AND SYNOVIUM FOR METADIAPHYSEAL LEG LENGTHENING (EXPERIMENTAL-AND-MORPHOLOGICAL STUDY)

    OpenAIRE

    T. A. Stupina; N. A. Schoudlo; N. V. Petrovskaya; M. A. Stepanov

    2013-01-01

    The knee articular cartilage and synovial membrane have been studied for metadiaphyseal leg lengthening using the methods of light miscroscopy, computer morpho- and stereometry. The manner of bone integrity breaking, the rate and rhythm of distraction conformed to the lengthening technique most often used in the clinic. The results of the histomorphometric analysis have demonstrated that when osteotomy at the level of metadiaphysis and manual distraction by 1 mm a day for 4 times is performed...

  1. Coleman-Weinberg symmetry breaking in an anisotropic spacetime

    International Nuclear Information System (INIS)

    Futamase, T.

    1984-01-01

    The Coleman-Weinberg mechanism of symmetry breaking in a Bianchi type-I universe is investigated. The one-loop effective potential for a phi 4 theory and for scalar electrodynamics is calculated by the zeta-function method. The result indicates that the symmetry of the theory will be restored in the highly anisotropic, cold, early universe, irrespective of the coupling between the scalar field and the spacetime curvature scalar. This mechanism of the phase transition explains the isotropy of our universe

  2. Are the hamstrings from the drive leg or landing leg more active in baseball pitchers? An electromyographic study.

    Science.gov (United States)

    Erickson, Brandon J; Zaferiou, Antonia; Chalmers, Peter N; Ruby, Deana; Malloy, Phillip; Luchetti, Timothy J; Verma, Nikhil N; Romeo, Anthony A

    2017-11-01

    Ulnar collateral ligament reconstruction (UCLR) has become a common procedure among baseball players of all levels. There are several graft choices in performing UCLR, one of which is a hamstring (gracilis or semitendinosus) autograft. It is unclear whether the hamstring muscle from a pitcher's drive leg (ipsilateral side of the UCLR) or landing leg (contralateral side of the UCLR) is more active during the pitching motion. We hypothesized that the landing leg semitendinosus will be more electromyographically active than the drive leg. Healthy, elite male pitchers aged 16-21 years were recruited. Sixteen pitchers (average age, 17.6 ± 1.6 years; 67% threw right handed) underwent electromyographic analysis. Pitchers threw 5 fastballs at 100% effort from the wind-up with electromyographic analysis of every pitch. Activation of the semitendinosus and biceps femoris in both legs was compared within pitchers and between pitchers. Hamstring activity was higher in the drive leg than in the landing leg during each phase and in sum, although the difference was significant only during the double support phase (P = .021). On within-pitcher analysis, 10 of 16 pitchers had significantly more sum hamstring activity in the drive leg than in the landing leg, while only 4 of 16 had more activity in the landing leg (P = .043). During the baseball pitch, muscle activity of the semitendinosus was higher in the drive leg than in the landing leg in most pitchers. Surgeons performing UCLR using hamstring autograft should consider harvesting the graft from the pitcher's landing leg to minimize disruption to the athlete's pitching motion. Copyright © 2017 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  3. Experiment data report for Semiscale Mod-1 Test S-05-2 (alternate ECC injection test)

    International Nuclear Information System (INIS)

    Feldman, E.M.; Collins, B.L.; Sackett, K.E.

    1977-02-01

    Recorded test data are presented for Test S-05-2 of the Semiscale Mod-1 alternate emergency core coolant (ECC) injection test series. This test is one of several Semiscale Mod-1 experiments conducted to investigate the thermal and hydraulic phenomena accompanying a hypothesized loss-of-coolant accident in a pressurized water reactor (PWR) system. Test S-05-2 was conducted from an initial cold leg fluid temperature of 545 0 F and an initial pressure of 2263 psia. A simulated double-ended offset shear cold leg break was used to investigate core and system response to a depressurization and reflood transient with ECC injection at the intact loop pump suction and broken loop cold leg. A reduced lower plenum volume was used for this test to more accurately represent the lower plenum of a PWR, based on system volume scaling. System flow was set to achieve a core fluid temperature differential of 65 0 F at a core power level of 1.44 MW. The flow resistance of the intact loop was based on core area scaling. An electrically heated core with a slightly peaked radial power profile was used in the pressure vessel to simulate the predicted surface heat flux of nuclear fuel rods during a loss-of-coolant accident

  4. Exertional Rhabdomyolysis in a Collegiate American Football Player After Preventive Cold-Water Immersion: A Case Report

    Science.gov (United States)

    Kahanov, Leamor; Eberman, Lindsey E.; Wasik, Mitchell; Alvey, Thurman

    2012-01-01

    Objective: To describe a case of exertional rhabdomyolysis in a collegiate American football player after preventive cold-water immersion. Background: A healthy man (19 years old) participated in full-contact football practice followed by conditioning (2.5 hours). After practice, he entered a coach-mandated post-practice cold-water immersion and had no signs of heat illness before developing leg cramps, for which he presented to the athletic training staff. After 10 minutes of repeated stretching, massage, and replacement of electrolyte-filled fluids, he was transported to the emergency room. Laboratory tests indicated a creatine kinase (CK) level of 2545 IU/L (normal range, 45–260 IU/L), CK-myoglobin fraction of 8.5 ng/mL (normal rhabdomyolysis. Treatment: The patient was treated with rest and rehydration. One week after the incident, he began biking and swimming. Eighteen days later, the patient continued to demonstrate elevated CK levels (527 IU/L) but described no other symptoms and was allowed to return to football practice as tolerated. Two months after the incident, his CK level remained high (1900 IU/L). Uniqueness: The athlete demonstrated no signs of heat illness upon entering the cold-water immersion but experienced severe leg cramping after immersion, resulting in a diagnosis of exertional rhabdomyolysis. Previously described cases have not linked cold-water immersion with the pathogenesis of rhabdomyolysis. Conclusions: In this football player, CK levels appeared to be a poor indicator of rhabdomyolysis. Our patient demonstrated no other signs of the illness weeks after the incident, yet his elevated CK levels persisted. Cold-water immersion immediately after exercise should be monitored by the athletic training staff and may not be appropriate to prevent muscle damage, given the lack of supporting evidence. PMID:22488291

  5. Analysis of a large-break LOCA at lower operational modes

    Energy Technology Data Exchange (ETDEWEB)

    Jeong, H.Y.; Jun, H.Y.; Lee, K. [Korea Electric Power Corporation, Taejon (Korea)

    2000-10-01

    To improve Technical Specifications and Emergency Operating Guidelines (EOGs) applicable at lower operational modes it is required to perform the safety analysis reflecting the operational characteristics in those modes. Because the component availability and system configurations at lower modes are different from those of power mode, the plant safety at lower modes should be confirmed through independent analyses. In the present study, a large-break loss-of-coolant accident is analyzed to evaluate the containment pressure and temperature control function for the preparation of EOGs applicable at lower modes. To reach the required shutdown condition, the plant cool-down is controlled by the secondary steam flow and auxiliary feedwater. The mass and energy releases from primary system are obtained from RELAP5/MOD3.1 calculation and the containment pressure and temperature are evaluated with CONTEMPT-LT code. The reference plant is Korean Next Generation Reactor having 4,000 MW thermal power. Two cases of cold leg LOCA initiated at Mode 3 with and without SIT operation are calculated. At the given plant conditions, all safety injection pumps are still available. The calculation at the condition of maximum mass and energy release shows that the containment pressure and temperature can be controlled within acceptable criteria, which means the operations of 2 or 4 fan coolers are the possible success paths to achieve the containment P/T control safety function. The peak cladding temperature with minimum safety injection flow does not show remarkable excursion, which implies the lower mode LOCA at Mode 3 can be bounded by the results obtained at full power from the viewpoint of ECCS performance. (author)

  6. Controlled fragmentation of multimaterial fibres and films via polymer cold-drawing.

    Science.gov (United States)

    Shabahang, Soroush; Tao, Guangming; Kaufman, Joshua J; Qiao, Yangyang; Wei, Lei; Bouchenot, Thomas; Gordon, Ali P; Fink, Yoel; Bai, Yuanli; Hoy, Robert S; Abouraddy, Ayman F

    2016-06-23

    Polymer cold-drawing is a process in which tensile stress reduces the diameter of a drawn fibre (or thickness of a drawn film) and orients the polymeric chains. Cold-drawing has long been used in industrial applications, including the production of flexible fibres with high tensile strength such as polyester and nylon. However, cold-drawing of a composite structure has been less studied. Here we show that in a multimaterial fibre composed of a brittle core embedded in a ductile polymer cladding, cold-drawing results in a surprising phenomenon: controllable and sequential fragmentation of the core to produce uniformly sized rods along metres of fibre, rather than the expected random or chaotic fragmentation. These embedded structures arise from mechanical-geometric instabilities associated with 'neck' propagation. Embedded, structured multimaterial threads with complex transverse geometry are thus fragmented into a periodic train of rods held stationary in the polymer cladding. These rods can then be easily extracted via selective dissolution of the cladding, or can self-heal by thermal restoration to re-form the brittle thread. Our method is also applicable to composites with flat rather than cylindrical geometries, in which case cold-drawing leads to the break-up of an embedded or coated brittle film into narrow parallel strips that are aligned normally to the drawing axis. A range of materials was explored to establish the universality of this effect, including silicon, germanium, gold, glasses, silk, polystyrene, biodegradable polymers and ice. We observe, and verify through nonlinear finite-element simulations, a linear relationship between the smallest transverse scale and the longitudinal break-up period. These results may lead to the development of dynamical and thermoreversible camouflaging via a nanoscale Venetian-blind effect, and the fabrication of large-area structured surfaces that facilitate high-sensitivity bio-detection.

  7. Leg og dannelse

    DEFF Research Database (Denmark)

    Skovbjerg, Helle Marie

    2017-01-01

    lederen i det pædagogiske tidskrift Asterisk: ”Leg i skolen, leg i klasserummet, ja legende læring i skolen udgør derimod en enorm, seriøs og ubrugt læringsressource – ikke alene med effekter på kreativiteten, men også på den faglige læring” (Holm, 2015, p. 2). Legens værdi gøres altså først og fremmest...

  8. The Motor and the Brake of the Trailing Leg in Human Walking: Leg Force Control Through Ankle Modulation and Knee Covariance

    Science.gov (United States)

    Toney, Megan E.; Chang, Young-Hui

    2016-01-01

    Human walking is a complex task, and we lack a complete understanding of how the neuromuscular system organizes its numerous muscles and joints to achieve consistent and efficient walking mechanics. Focused control of select influential task-level variables may simplify the higher-level control of steady state walking and reduce demand on the neuromuscular system. As trailing leg power generation and force application can affect the mechanical efficiency of step-to-step transitions, we investigated how joint torques are organized to control leg force and leg power during human walking. We tested whether timing of trailing leg force control corresponded with timing of peak leg power generation. We also applied a modified uncontrolled manifold analysis to test whether individual or coordinated joint torque strategies most contributed to leg force control. We found that leg force magnitude was adjusted from step-to-step to maintain consistent leg power generation. Leg force modulation was primarily determined by adjustments in the timing of peak ankle plantar-flexion torque, while knee torque was simultaneously covaried to dampen the effect of ankle torque on leg force. We propose a coordinated joint torque control strategy in which the trailing leg ankle acts as a motor to drive leg power production while trailing leg knee torque acts as a brake to refine leg power production. PMID:27334888

  9. The Occurrence of Cold Spells in the Alps Related to ClimateChange

    Directory of Open Access Journals (Sweden)

    Seon Ki Park

    2010-08-01

    Full Text Available Climate change is not only a likely prospect for the end of this century, but it is already occurring. Part of the changes will include global warming and increasing temperature variability, both at global and regional scales. This increased variability was investigated in this paper from the point of view of the occurrence of cold spells in the Alps in the future climate (2071–2100, compared with the present climate (1961–1990. For this purpose, a regionalisation of the climate change effects was performed within the Alps. To avoid possible errors in the estimate of the 2m air temperature, the analysis was performed on the soil surface temperature. To get realistic values for this variable, a land surface scheme, UTOPIA, has been run on the selected domain, using the output of the Regional Climate Model (RegCM3 simulations as the driving force. The results show that, in general, the number of cold breaks is decreasing over the Alps, due to the temperature increment. However, there are certain zones where the behaviour is more complicated. The analysis of the model output also allowed a relationship to be found between the number of cold breaks and their duration. The significance of these results over the whole area was assessed.

  10. A Hydroxyurea-induced Leg Ulcer

    OpenAIRE

    Hwang, Seon-Wook; Hong, Soon-Kwon; Kim, Sang-Hyun; Seo, Jong-Keun; Lee, Deborah; Sung, Ho-Suk

    2009-01-01

    Hydroxyurea is a cytostatic agent that has recently become the drug of choice in the treatment of various myeloproliferative diseases. The cutaneous side effects of hydroxyurea include xerosis, hyperpigmentation, nail discoloration, and scaling. Leg ulcers have only rarely been reported in association with hydroxyurea treatment. A 75-year-old woman presented with leg ulcers, nail discoloration, and xerosis. The leg ulcers were refractory to conventional treatment. She had been taking oral hyd...

  11. Dissipative - free jumps for the magnetoacoustic branch of cold plasma motions

    International Nuclear Information System (INIS)

    Bakholdin, I.B.

    2000-01-01

    Dissipative-free jumps were studied in hydrodynamic model of cold plasma moving with the rate close to magnetoacoustic one. The jumps for the generalized Korteweg-de Vries equation with similar nonlinear and dispersion properties were studied. Among them there were jumps with emission and solution type jumps. Furthermore, the numerical investigation into the initial break decomposition in cold plasma confirmed the validity of assumption that in the given type of jumps as in case of the generalized Korteweg-de Vries equation. Paper describes the analytical method enabling to forecast the structure nature of such jumps in the general case [ru

  12. Assessment of BETHSY Test 9.1.b using RELAP5/MOD3

    International Nuclear Information System (INIS)

    Lee, S.; Chung, B.D.; Kim, H.J.

    1993-06-01

    The 2'' cold leg break test 9.l.b, conducted at the BETHSY facility was analyzed using the RELAP5/MOD3 Version 5m5 code. The test 9.l.b was conducted with the main objective being the investigation of the thermal-hydraulic mechanisms responsible for the large core uncovery and fuel heat-up, requiring the implementation of an ultimate procedure. The present analysis demonstrates the code's capability to predict, with sufficient accuracy, the main phenomena occurring in the depressurization transient, both from a qualitative and quantitative point of view. Nevertheless, several differences regarding the evolution of phenomena and affecting the timing order have to be pointed out in the base calculation. Three calculations were carried out to study the sensitivity to change of the nodalization in the components of the loop seal cross-over legs, and of the auxiliary feedwater control logics, and of the break discharge coefficient

  13. Determinants and Politics of German Military Transformation in the Post-Cold War Era

    Science.gov (United States)

    2011-06-01

    Cold War. Additionally, the prevalent antimilitarism called for armed forces that had to break with their historic record of authoritarianism and... paternalism ‖ in NATO affairs. In light of these diverging perceptions, the new Strategic Concept (SC 99), approved at the anniversary summit in

  14. Recovery From Exercise-Induced Muscle Damage: Cold-Water Immersion Versus Whole-Body Cryotherapy.

    Science.gov (United States)

    Abaïdia, Abd-Elbasset; Lamblin, Julien; Delecroix, Barthélémy; Leduc, Cédric; McCall, Alan; Nédélec, Mathieu; Dawson, Brian; Baquet, Georges; Dupont, Grégory

    2017-03-01

    To compare the effects of cold-water immersion (CWI) and whole-body cryotherapy (WBC) on recovery kinetics after exercise-induced muscle damage. Ten physically active men performed single-leg hamstring eccentric exercise comprising 5 sets of 15 repetitions. Immediately postexercise, subjects were exposed in a randomized crossover design to CWI (10 min at 10°C) or WBC (3 min at -110°C) recovery. Creatine kinase concentrations, knee-flexor eccentric (60°/s) and posterior lower-limb isometric (60°) strength, single-leg and 2-leg countermovement jumps, muscle soreness, and perception of recovery were measured. The tests were performed before and immediately, 24, 48, and 72 h after exercise. Results showed a very likely moderate effect in favor of CWI for single-leg (effect size [ES] = 0.63; 90% confidence interval [CI] = -0.13 to 1.38) and 2-leg countermovement jump (ES = 0.68; 90% CI = -0.08 to 1.43) 72 h after exercise. Soreness was moderately lower 48 h after exercise after CWI (ES = -0.68; 90% CI = -1.44 to 0.07). Perception of recovery was moderately enhanced 24 h after exercise for CWI (ES = -0.62; 90% CI = -1.38 to 0.13). Trivial and small effects of condition were found for the other outcomes. CWI was more effective than WBC in accelerating recovery kinetics for countermovement-jump performance at 72 h postexercise. CWI also demonstrated lower soreness and higher perceived recovery levels across 24-48 h postexercise.

  15. Best-estimate analysis of a loss-of-coolant accident in a four-loop US PWR using TRAC-PD2

    International Nuclear Information System (INIS)

    Ireland, J.R.

    1982-01-01

    A 200-percent double-ended cold-leg break loss-of-coolant accident (LOCA) in a typical US pressurized water reactor (PWR) was simulated using the Transient Reactor Analysis Code (TRAC-PD2). The reactor system modeled represented a typical US PWR with four loops (three intact, one broken) and cold-leg emergency-core-cooling systems (ECCS). The finely noded TRAC model employed 440 three dimensional (r, THETA, z) vessel cells along with approximately 300 one-dimensional cells that modeled the primary system loops. The calculated peak-clad temperature of 950 0 K occurred during blowdown and the clad temperature excursion was terminated at 175 s, when complete core quenching occurred. Accumulator flows were initiated at 10 s, when the system pressure reached 4.08 MPa, and the refill phase ended at 36 s when the lower plenum refilled. During reflood, both bottom and falling film quench fronts were calculated

  16. Pipe crawler with extendable legs

    International Nuclear Information System (INIS)

    Zollinger, W.T.

    1992-01-01

    A pipe crawler for moving through a pipe in inchworm fashion having front and rear leg assemblies separated by air cylinders to increase and decrease the spacing between assemblies. Each leg of the four legs of an assembly is moved between a wall-engaging, extended position and a retracted position by a separate air cylinder. The air cylinders of the leg assemblies are preferably arranged in pairs of oppositely directed cylinders with no pair lying in the same axial plane as another pair. Therefore, the cylinders can be as long as a leg assembly is wide and the crawler can crawl through sections of pipes where the diameter is twice that of other sections. The crawler carries a valving system, a manifold to distribute air supplied by a single umbilical air hose to the various air cylinders in a sequence controlled electrically by a controller. The crawler also utilizes a rolling mechanism, casters in this case, to reduce friction between the crawler and pipe wall thereby further extending the range of the pipe crawler. 8 figs

  17. Pipe crawler with extendable legs

    Science.gov (United States)

    Zollinger, W.T.

    1992-06-16

    A pipe crawler for moving through a pipe in inchworm fashion having front and rear leg assemblies separated by air cylinders to increase and decrease the spacing between assemblies. Each leg of the four legs of an assembly is moved between a wall-engaging, extended position and a retracted position by a separate air cylinder. The air cylinders of the leg assemblies are preferably arranged in pairs of oppositely directed cylinders with no pair lying in the same axial plane as another pair. Therefore, the cylinders can be as long as a leg assembly is wide and the crawler can crawl through sections of pipes where the diameter is twice that of other sections. The crawler carries a valving system, a manifold to distribute air supplied by a single umbilical air hose to the various air cylinders in a sequence controlled electrically by a controller. The crawler also utilizes a rolling mechanism, casters in this case, to reduce friction between the crawler and pipe wall thereby further extending the range of the pipe crawler. 8 figs.

  18. The Advanced Neutron Source liquid deuterium cold source

    International Nuclear Information System (INIS)

    Lucas, A.T.

    1995-08-01

    The Advanced Neutron Source will employ two cold sources to moderate neutrons to low energy (<10 meV). The cold neutrons produced are then passed through beam guides to various experiment stations. Each cold source moderator is a sphere of 410-mm internal diameter. The moderator material is liquid deuterium flowing at a rate of 1 kg/s and maintained at subcooled temperatures at all points of the circuit, to prevent boiling. Nuclear beat deposited within the liquid deuterium and its containment structure totals more than 30 kW. All of this heat is removed by the liquid deuterium, which raises its temperature by 5 K. The liquid prime mover is a cryogenic circulator that is situated in the return leg of the flow loop. This arrangement minimizes the heat added to the liquid between the heat exchanger and the moderator vessel, allowing the moderator to be operated at the minimum practical temperature. This report describes the latest thinking at the time of project termination. It also includes the status of various systems at that time and outlines anticipated directions in which the design would have progressed. In this regard, some detail differences between this report and official design documents reflect ideas that were not approved at the time of closure but are considered noteworthy

  19. Leg som ustyrlig deltagelseskultur

    DEFF Research Database (Denmark)

    Toft, Herdis

    2017-01-01

    - og spilteoretikere Johan Huizinga og Roger Caillois. Deres teorier og begrebsdannelser har været brugt til at påpege leg dels som et æstetisk baseret betydningssystem, dels som et affektivt og stemningsbaseret oplevelsessystem samt endelig som et socialt baseret relationssystem. I artiklen vælger vi...... at fokusere på leg som et socialt baseret relationssystem og yderligere zoome ind på et af legens systemiske væsenstræk, nemlig brugen af regulerbare regelsæt, som legerne uden ’politi’ forhandler sig frem til før, under og efter legen. Fælles for Huizinga og Caillois er, at de knytter leg uløseligt sammen...

  20. Thermo-mechanical Design Methodology for ITER Cryodistribution cold boxes

    Science.gov (United States)

    Shukla, Vinit; Patel, Pratik; Das, Jotirmoy; Vaghela, Hitensinh; Bhattacharya, Ritendra; Shah, Nitin; Choukekar, Ketan; Chang, Hyun-Sik; Sarkar, Biswanath

    2017-04-01

    The ITER cryo-distribution (CD) system is in charge of proper distribution of the cryogen at required mass flow rate, pressure and temperature level to the users; namely the superconducting (SC) magnets and cryopumps (CPs). The CD system is also capable to use the magnet structures as a thermal buffer in order to operate the cryo-plant as much as possible at a steady state condition. A typical CD cold box is equipped with mainly liquid helium (LHe) bath, heat exchangers (HX’s), cryogenic valves, filter, heaters, cold circulator, cold compressor and process piping. The various load combinations which are likely to occur during the life cycle of the CD cold boxes are imposed on the representative model and impacts on the system are analyzed. This study shows that break of insulation vacuum during nominal operation (NO) along with seismic event (Seismic Level-2) is the most stringent load combination having maximum stress of 224 MPa. However, NO+SMHV (Séismes Maximaux Historiquement Vraisemblables = Maximum Historically Probable Earthquakes) load combination is having the least safety margin and will lead the basis of the design of the CD system and its sub components. This paper presents and compares the results of different load combinations which are likely to occur on a typical CD cold box.

  1. Legāti

    OpenAIRE

    Segliņa, Aiga

    2010-01-01

    Autore teorētiski analizē legāta jēdzienu testamentārās mantošanas ietvaros un atspoguļo praktiska pētījuma rezultātus. Teorētiskā daļa apskata legāta nodibināšanas formu un spēkā esamību, tā iegūšanu un atraidīšanu, izpildi un zaudēšanu, novēlējuma robežas un aprobežojumus. Pētījums veikts aptaujas veidā ar mērķi noskaidrot, cik liela Latvijas iedzīvotāju daļa apzinās legāta nodrošinātās priekšrocības testamentārajā mantošanā. Apskatīts notāra neitralitātes jautājums attiecībā pret mantošana...

  2. Nonlinear mode interaction in equal-leg angle struts susceptible to cellular buckling.

    Science.gov (United States)

    Bai, L; Wang, F; Wadee, M A; Yang, J

    2017-11-01

    A variational model that describes the interactive buckling of a thin-walled equal-leg angle strut under pure axial compression is presented. A formulation combining the Rayleigh-Ritz method and continuous displacement functions is used to derive a system of differential and integral equilibrium equations for the structural component. Solving the equations using numerical continuation reveals progressive cellular buckling (or snaking) arising from the nonlinear interaction between the weak-axis flexural buckling mode and the strong-axis flexural-torsional buckling mode for the first time-the resulting behaviour being highly unstable. Physical experiments conducted on 10 cold-formed steel specimens are presented and the results show good agreement with the variational model.

  3. Immediate effects of the trunk stabilizing exercise on static balance parameters in double-leg and one-leg stances

    OpenAIRE

    Kim, Jwa-jun; Park, Se-yeon

    2016-01-01

    [Purpose] The purpose of this study was to evaluate the immediate effect of stabilizing exercise using the PNF technique on standing balance in one-leg and double-leg stances. [Subjects and Methods] The present study recruited 34 healthy participants from a local university. The Participants performed four balance tests (double-leg stance with and without vision, one-leg stance with and without vision), before and after exercise. The exercise consisted of exercises performed using PNF techniq...

  4. Artificial Leg Design and Control Research of a Biped Robot with Heterogeneous Legs Based on PID Control Algorithm

    Directory of Open Access Journals (Sweden)

    Hualong Xie

    2015-04-01

    Full Text Available A biped robot with heterogeneous legs (BRHL is proposed to provide an ideal test-bed for intelligent bionic legs (IBL. To make artificial leg gait better suited to a human, a four-bar mechanism is used as its knee joint, and a pneumatic artificial muscle (PAM is used as its driving source. The static mathematical model of PAM is established and the mechanical model of a single degree of freedom of a knee joint driven by PAM is analyzed. A control simulation of an artificial leg based on PID control algorithm is carried out and the simulation results indicate that the artificial leg can simulate precisely a normal human walking gait.

  5. Spontaneous Symmetry-Breaking in a Network Model for Quadruped Locomotion

    Science.gov (United States)

    Stewart, Ian

    2017-12-01

    Spontaneous symmetry-breaking proves a mechanism for pattern generation in legged locomotion of animals. The basic timing patterns of animal gaits are produced by a network of spinal neurons known as a Central Pattern Generator (CPG). Animal gaits are primarily characterized by phase differences between leg movements in a periodic gait cycle. Many different gaits occur, often having spatial or spatiotemporal symmetries. A natural way to explain gait patterns is to assume that the CPG is symmetric, and to classify the possible symmetry-breaking periodic motions. Pinto and Golubitsky have discussed a four-node model CPG network for biped gaits with ℤ2 × ℤ2 symmetry, classifying the possible periodic states that can arise. A more specific rate model with this structure has been analyzed in detail by Stewart. Here we extend these methods to quadruped gaits, using an eight-node network with ℤ4 × ℤ2 symmetry proposed by Golubitsky and coworkers. We formulate a rate model and calculate how the first steady or Hopf bifurcation depends on its parameters, which represent four connection strengths. The calculations involve a distinction between “real” gaits with one or two phase shifts (pronk, bound, pace, trot) and “complex” gaits with four phase shifts (forward and reverse walk, forward and reverse buck). The former correspond to real eigenvalues of the connection matrix, the latter to complex conjugate pairs. The partition of parameter space according to the first bifurcation, ignoring complex gaits, is described explicitly. The complex gaits introduce further complications, not yet fully understood. All eight gaits can occur as the first bifurcation from a fully synchronous equilibrium, for suitable parameters, and numerical simulations indicate that they can be asymptotically stable.

  6. Robust and efficient walking with spring-like legs

    Energy Technology Data Exchange (ETDEWEB)

    Rummel, J; Blum, Y; Seyfarth, A, E-mail: juergen.rummel@uni-jena.d, E-mail: andre.seyfarth@uni-jena.d [Lauflabor Locomotion Laboratory, University of Jena, Dornburger Strasse 23, 07743 Jena (Germany)

    2010-12-15

    The development of bipedal walking robots is inspired by human walking. A way of implementing walking could be performed by mimicking human leg dynamics. A fundamental model, representing human leg dynamics during walking and running, is the bipedal spring-mass model which is the basis for this paper. The aim of this study is the identification of leg parameters leading to a compromise between robustness and energy efficiency in walking. It is found that, compared to asymmetric walking, symmetric walking with flatter angles of attack reveals such a compromise. With increasing leg stiffness, energy efficiency increases continuously. However, robustness is the maximum at moderate leg stiffness and decreases slightly with increasing stiffness. Hence, an adjustable leg compliance would be preferred, which is adaptable to the environment. If the ground is even, a high leg stiffness leads to energy efficient walking. However, if external perturbations are expected, e.g. when the robot walks on uneven terrain, the leg should be softer and the angle of attack flatter. In the case of underactuated robots with constant physical springs, the leg stiffness should be larger than k-tilde = 14 in order to use the most robust gait. Soft legs, however, lack in both robustness and efficiency.

  7. Robust and efficient walking with spring-like legs

    International Nuclear Information System (INIS)

    Rummel, J; Blum, Y; Seyfarth, A

    2010-01-01

    The development of bipedal walking robots is inspired by human walking. A way of implementing walking could be performed by mimicking human leg dynamics. A fundamental model, representing human leg dynamics during walking and running, is the bipedal spring-mass model which is the basis for this paper. The aim of this study is the identification of leg parameters leading to a compromise between robustness and energy efficiency in walking. It is found that, compared to asymmetric walking, symmetric walking with flatter angles of attack reveals such a compromise. With increasing leg stiffness, energy efficiency increases continuously. However, robustness is the maximum at moderate leg stiffness and decreases slightly with increasing stiffness. Hence, an adjustable leg compliance would be preferred, which is adaptable to the environment. If the ground is even, a high leg stiffness leads to energy efficient walking. However, if external perturbations are expected, e.g. when the robot walks on uneven terrain, the leg should be softer and the angle of attack flatter. In the case of underactuated robots with constant physical springs, the leg stiffness should be larger than k-tilde = 14 in order to use the most robust gait. Soft legs, however, lack in both robustness and efficiency.

  8. Does a crouched leg posture enhance running stability and robustness?

    Science.gov (United States)

    Blum, Yvonne; Birn-Jeffery, Aleksandra; Daley, Monica A; Seyfarth, Andre

    2011-07-21

    Humans and birds both walk and run bipedally on compliant legs. However, differences in leg architecture may result in species-specific leg control strategies as indicated by the observed gait patterns. In this work, control strategies for stable running are derived based on a conceptual model and compared with experimental data on running humans and pheasants (Phasianus colchicus). From a model perspective, running with compliant legs can be represented by the planar spring mass model and stabilized by applying swing leg control. Here, linear adaptations of the three leg parameters, leg angle, leg length and leg stiffness during late swing phase are assumed. Experimentally observed kinematic control parameters (leg rotation and leg length change) of human and avian running are compared, and interpreted within the context of this model, with specific focus on stability and robustness characteristics. The results suggest differences in stability characteristics and applied control strategies of human and avian running, which may relate to differences in leg posture (straight leg posture in humans, and crouched leg posture in birds). It has been suggested that crouched leg postures may improve stability. However, as the system of control strategies is overdetermined, our model findings suggest that a crouched leg posture does not necessarily enhance running stability. The model also predicts different leg stiffness adaptation rates for human and avian running, and suggests that a crouched avian leg posture, which is capable of both leg shortening and lengthening, allows for stable running without adjusting leg stiffness. In contrast, in straight-legged human running, the preparation of the ground contact seems to be more critical, requiring leg stiffness adjustment to remain stable. Finally, analysis of a simple robustness measure, the normalized maximum drop, suggests that the crouched leg posture may provide greater robustness to changes in terrain height

  9. Leg intravenous pressure during head-up tilt.

    NARCIS (Netherlands)

    Groothuis, J.T.; Poelkens, F.; Wouters, C.W.; Kooijman, H.M.; Hopman, M.T.E.

    2008-01-01

    Leg vascular resistance is calculated as the arterial-venous pressure gradient divided by blood flow. During orthostatic challenges it is assumed that the hydrostatic pressure contributes equally to leg arterial, as well as to leg venous pressure. Because of venous valves, one may question whether,

  10. Doppler ultrasound exam of an arm or leg

    Science.gov (United States)

    Peripheral vascular disease - Doppler; PVD - Doppler; PAD - Doppler; Blockage of leg arteries - Doppler; Intermittent claudication - Doppler; Arterial insufficiency of the legs - Doppler; Leg pain and ...

  11. Best-estimate analysis of a loss-of-coolant accident in a four-loop US PWR using TRAC-PD2

    International Nuclear Information System (INIS)

    Ireland, J.R.

    1982-01-01

    A 200% double-ended cold-leg break loss-of-coolant accident (LOCA) in a typical US pressurized water reactor (PWR) was simulated using the Transient Reactor Analysis Code (TRAC-PD2). The reactor system modeled represented a typical US PWR with four loops and cold-leg emergency-core-cooling systems (ECCS). The calculated peak cladding temperature of 950 K occurred during blowdown and the cladding temperature excursion was terminated at 175 s when complete core quenching occurred. Accumulator flows were initiated at 10 s when the system pressure reached 4.08 MPa, and the refill phase ended at 36 s when the lower plenum refilled. During reflood, both bottom and falling film quench fronts were calculated. Top quenching was caused by entrainment from the lower plenum and lower core regions. The entrained liquid was sufficient to form a small, saturated pool (0.3 m deep) above the upper core support plate. Also, some of the entrained liquid was carried out the hot legs and vaporized in the steam generators. Strong multidimensional effects were calculated in the reactor vessel, particularly with respect to rod quenching

  12. Assessment of the vibration on the foam legged and sheet metal-legged passenger seat

    Directory of Open Access Journals (Sweden)

    L. Dahil

    2015-10-01

    Full Text Available In this study, it was aim ed to decrease the vibration reaching to passenger from the legs of vehicle seats. In order to determine the levels of vibrations reaching at passengers, a test pad placed under the passenger seat was used, and HVM100 device was used for digitizing the information obtained. By transferring the vibration data to system by using HVM100 device, the acceleration graphics were prepared with Blaze software. As a result, it was determined that the acceleration values of seat legs made of foam material were lower than that of seat legs made of 2 mm thick sheet metal, so they damped the vibration better.

  13. Frustrated S = 1/2 Two-Leg Ladder with Different Leg Interactions

    Science.gov (United States)

    Tonegawa, Takashi; Okamoto, Kiyomi; Hikihara, Toshiya; Sakai, Tôru

    2017-04-01

    We explore the ground-state phase diagram of the S = 1/2 two-leg ladder. The isotropic leg interactions J1,a and J1,b between nearest neighbor spins in the legs a and b, respectively, are different from each other. The xy and z components of the uniform rung interactions are denoted by Jr and ΔJr, respectively, where Δ is the XXZ anisotropy parameter. This system has a frustration when J1,aJ1,b employ the physical consideration, the level spectroscopy analysis of the results obtained by the exact diagonalization method and also the density-matrix renormalization-group method. It is found that the non-collinear ferrimagnetic (NCFR) state appears as the ground state in the frustrated region of the parameters. Furthermore, the direct-product triplet-dimer (TD) state in which all rungs form the TD pair is the exact ground state, when J1,a + J1,b = 0 and 0≤ Δ ≲ 0.83. The obtained phase diagrams consist of the TD, XY and Haldane phases as well as the NCFR phase.

  14. Cold in-place recycling using solventless emulsion - phase IV (emulsion qualification and long-term field performance).

    Science.gov (United States)

    2016-05-01

    This report looks into how a successful Cold In-Place solventless emulsion behaves and how the emulsion : break test developed in Phase III of this project demonstrates that behavior. Modifications to the test have been : made to improve the consiste...

  15. RELAP/MOD3.2 Assessment Using an 11% Upper Plenum Break Experiment in the PSB Facility

    Energy Technology Data Exchange (ETDEWEB)

    Bayless, P.D.

    2003-01-17

    The RELAP/MOD3.2 computer code has been assessed using an 11% upper plenum break experiment in the PSB test facility at the Electrogorsk Research and Engineering Center. This work was performed as part of the U.S. Department of Energy's International Nuclear Safety Program, and is part of the effort addressing the capability of the RELAP5/MOD3.2 code to model transients in Soviet-designed reactors. Designated VVER Standard Problem PSBV1, the test addressed several important phenomena related to VVER behavior that the code needs to simulate well. The code was judged to reasonably model the phenomena of two-phase flow natural circulation in the primary coolant system, asymmetric loop behavior, leak flow, loop seal clearance in the cold legs, heat transfer in a covered core, heat transfer in a partially covered core, pressurizer thermal-hydraulics, and integral system effects. The code was judged to be in minimal agreement with the experiment data for the mixture level and entrainment in the core, leading to a user recommendation to assess the sensitivity of transient calculations to the interphase drag modeling in the core. No judgments were made for the phenomena of phase separation without mixture level formation, mixture level and entrainment in the steam generators, pool formation in the upper plenum, or flow stratification in horizontal pipes because either the phenomenon did not occur in the test or there were insufficient measurements to characterize the behavior.

  16. RELAP/MOD3.2 Assessment Using an 11% Upper Plenum Break Experiment in the PSB Facility

    International Nuclear Information System (INIS)

    Bayless, P.D.

    2003-01-01

    The RELAP/MOD3.2 computer code has been assessed using an 11% upper plenum break experiment in the PSB test facility at the Electrogorsk Research and Engineering Center. This work was performed as part of the U.S. Department of Energy's International Nuclear Safety Program, and is part of the effort addressing the capability of the RELAP5/MOD3.2 code to model transients in Soviet-designed reactors. Designated VVER Standard Problem PSBV1, the test addressed several important phenomena related to VVER behavior that the code needs to simulate well. The code was judged to reasonably model the phenomena of two-phase flow natural circulation in the primary coolant system, asymmetric loop behavior, leak flow, loop seal clearance in the cold legs, heat transfer in a covered core, heat transfer in a partially covered core, pressurizer thermal-hydraulics, and integral system effects. The code was judged to be in minimal agreement with the experiment data for the mixture level and entrainment in the core, leading to a user recommendation to assess the sensitivity of transient calculations to the interphase drag modeling in the core. No judgments were made for the phenomena of phase separation without mixture level formation, mixture level and entrainment in the steam generators, pool formation in the upper plenum, or flow stratification in horizontal pipes because either the phenomenon did not occur in the test or there were insufficient measurements to characterize the behavior

  17. Approach to leg edema

    Directory of Open Access Journals (Sweden)

    Fulvio Pomero

    2017-09-01

    Full Text Available Edema is defined as a palpable swelling caused by an increase in interstitial fluid volume. Leg edema is a common problem with a wide range of possible causes and is the result of an imbalance in the filtration system between the capillary and interstitial spaces. Major causes of edema include venous obstruction, increased capillary permeability and increased plasma volume secondary to sodium and water retention. In both hospital and general practice, the patient with a swollen leg presents a common dilemma in diagnosis and treatment. The cause may be trivial or life-threatening and it is often difficult to determine the clinical pathway. The diagnosis can be narrowed by categorizing the edema according to its duration, distribution (unilateral or bilateral and accompanying symptoms. This work provides clinically oriented recommendations for the management of leg edema in adults.

  18. Consistency of Trend Break Point Estimator with Underspecified Break Number

    Directory of Open Access Journals (Sweden)

    Jingjing Yang

    2017-01-01

    Full Text Available This paper discusses the consistency of trend break point estimators when the number of breaks is underspecified. The consistency of break point estimators in a simple location model with level shifts has been well documented by researchers under various settings, including extensions such as allowing a time trend in the model. Despite the consistency of break point estimators of level shifts, there are few papers on the consistency of trend shift break point estimators in the presence of an underspecified break number. The simulation study and asymptotic analysis in this paper show that the trend shift break point estimator does not converge to the true break points when the break number is underspecified. In the case of two trend shifts, the inconsistency problem worsens if the magnitudes of the breaks are similar and the breaks are either both positive or both negative. The limiting distribution for the trend break point estimator is developed and closely approximates the finite sample performance.

  19. Revisiting LOFT L2-5 large break test in BEMUSE project context. Sensitivity studies

    International Nuclear Information System (INIS)

    Perez, Marina; Batet, Lluis; Pretel, Carme; Reventos, Francesc

    2005-01-01

    Full text of publication follows: Best estimate codes simulate NPPs behavior in principle without any special conservative assumptions. Due to several factors like code solution methods or user effects, the output parameters calculated have an uncertainty associated. The quantification of the these uncertainties becomes crucial when a safety statement is to be made. It is in this scope that GAMA group from CSNI (OECD/NEA) proposed the international BEMUSE project (Best Estimate - Uncertainty and Sensitivity Evaluation) having as main objective the evaluation of different methodologies for the uncertainty and sensitivity analysis of best-estimate code calculations. A number of methodologies prepared in different countries are used in the development of the project activities. The program work consists of 6 phases and currently the first two have already been concluded. Phase II consists in revisiting the ISP-13, the LOFT loss of coolant experiment L2-5 which simulated a double ended 200% cold leg break of a commercial PWR simultaneous with a loss of site power. In order to connect phase II with phase III, in which the uncertainty analysis will be carried out, quite a large number of sensitivity analysis have been performed by simulating system failures and varying fuel elements parameters among others. The presentation will focus on the results of the sensitivity analysis as well as its importance with regards to the uncertainty studies. The methodology used by UPC team was developed by ENUSA and the work is supported by the Spanish regulatory organization. (authors)

  20. Evaluation of arm-leg coordination in flat breaststroke.

    Science.gov (United States)

    Chollet, D; Seifert, L; Leblanc, H; Boulesteix, L; Carter, M

    2004-10-01

    This study proposes a new method to evaluate arm-leg coordination in flat breaststroke. Five arm and leg stroke phases were defined with a velocity-video system. Five time gaps quantified the time between arm and leg actions during three paces of a race (200 m, 100 m and 50 m) in 16 top level swimmers. Based on these time gaps, effective glide, effective propulsion, effective leg insweep and effective recovery were used to identify the different stroke phases of the body. A faster pace corresponded to increased stroke rate, decreased stroke length, increased propulsive phases, shorter glide phases, and a shorter T1 time gap, which measured the effective body glide. The top level swimmers showed short time gaps (T2, T3, T4, measuring the timing of arm-leg recoveries), which reflected the continuity in arm and leg actions. The measurement of these time gaps thus provides a pertinent evaluation of swimmers' skill in adapting their arm-leg coordination to biomechanical constraints.

  1. Relationship between Leg Mass, Leg Composition and Foot Velocity on Kicking Accuracy in Australian Football.

    Science.gov (United States)

    Hart, Nicolas H; Nimphius, Sophia; Spiteri, Tania; Cochrane, Jodie L; Newton, Robert U

    2016-06-01

    Kicking a ball accurately over a desired distance to an intended target is arguably the most important skill to acquire in Australian Football. Therefore, understanding the potential mechanisms which underpin kicking accuracy is warranted. The aim of this study was to examine the relationship between leg mass, leg composition and foot velocity on kicking accuracy in Australian Football. Thirty-one Australian Footballers (n = 31; age: 22.1 ± 2.8 years; height: 1.81 ± 0.07 m; weight: 85.1 ± 13.0 kg; BMI: 25.9 ± 3.2) each performed ten drop punt kicks over twenty metres to a player target. Athletes were separated into accurate (n = 15) and inaccurate (n = 16) kicking groups. Leg mass characteristics were assessed using whole body DXA scans. Foot velocity was determined using a ten-camera optoelectronic, three-dimensional motion capture system. Interactions between leg mass and foot velocity evident within accurate kickers only (r = -0.670 to -0.701). Relative lean mass was positively correlated with kicking accuracy (r = 0.631), while no relationship between foot velocity and kicking accuracy was evident in isolation (r = -0.047 to -0.083). Given the evident importance of lean mass, and its interaction with foot velocity for accurate kickers; future research should explore speed-accuracy, impulse-variability, limb co-ordination and foot-ball interaction constructs in kicking using controlled with-in subject studies to examine the effects of resistance training and skill acquisition programs on the development of kicking accuracy. Key pointsAccurate kickers expressed a very strong inverse relationship between leg mass and foot velocity. Inaccurate kickers were unable to replicate this, with greater volatility in their performance, indicating an ability of accurate kickers to mediate foot velocity to compensate for leg mass in order to deliver the ball over the required distance.Accurate kickers exhibited larger quantities of relative lean mass and lower quantities

  2. Unification of SUSY breaking and GUT breaking

    Energy Technology Data Exchange (ETDEWEB)

    Kobayashi, Tatsuo [Department of Physics, Hokkaido University,Sapporo 060-0810 (Japan); Omura, Yuji [Department of Physics, Nagoya University,Nagoya 464-8602 (Japan)

    2015-02-18

    We build explicit supersymmetric unification models where grand unified gauge symmetry breaking and supersymmetry (SUSY) breaking are caused by the same sector. Besides, the SM-charged particles are also predicted by the symmetry breaking sector, and they give the soft SUSY breaking terms through the so-called gauge mediation. We investigate the mass spectrums in an explicit model with SU(5) and additional gauge groups, and discuss its phenomenological aspects. Especially, nonzero A-term and B-term are generated at one-loop level according to the mediation via the vector superfields, so that the electro-weak symmetry breaking and 125 GeV Higgs mass may be achieved by the large B-term and A-term even if the stop mass is around 1 TeV.

  3. Duplex sonography of the near-surface leg veins

    International Nuclear Information System (INIS)

    Mendoza, E.

    2007-01-01

    The book contains the following contributions: The ultrasonograph, selection of the ultrasonic transducer, anatomy of the near-surface vein system, physiology of the near-surface vein system, varicose status classification, systematics of the duplex sonography of near-surface leg veins, provocational maneuver for the duplex sonographic varicose diagnostics, exploration of vena saphena parva, perforans veins, side branches, phlebitis, sonography for varicose therapy, postsurgical sonography, deep leg veins, examination of near-surface leg veins for the pathology of the deep vein system, differential diagnostic clarification of leg oedema from the phlebologic-lymphological view, diagnostic side features along the near-surface leg veins

  4. Comparision of calculations for the ROSA-IV LSTF with RELAP5/MOD0 and RELAP5/MOD1 (cycle 1)

    International Nuclear Information System (INIS)

    Fineman, C.P.; Tanaka, Mitsugu; Tasaka, Kanji

    1982-03-01

    10% and 2.5% cold leg break analyses have been completed for the ROSA-IV Large Scale Test Facility (LSTF) with the RELAP5/MOD0 and RELAP5/MOD1, cycle 1, computer codes. Comparisons between the calculations were made to determine any differences in the results obtained from the two versions of RELAP5. Differences in the two calculations were found which can be attributed to changes in the flow regime maps and critical flow model. (author)

  5. A cold mass support system based on the use of oriented fiberglass epoxy rods in bending

    International Nuclear Information System (INIS)

    Green, Michael A.; Corradi, Carol A.; LaMantia, Roberto F.; Zbasnik, Jon P.

    2002-01-01

    This report describes a cold mass support system that uses oriented fiberglass epoxy (other low heat leak oriented fiber material can also be used) rods. In the direction of the rods, where forces are carried in tension or compression, the support system is very stiff. In the other directions, the rods are subjected to bending stresses. When the support rods are put in bending the cold mass support is quite compliant. This type of support system can be used in situation where space for a cold mass support system is limited and where compliance can be tolerated in at least one direction. Break test data for 15.9-mm and 19.1-mm diameter oriented fiberglass rods is presented in this report. The cold mass supports for the DFBX distribution boxes are presented as an example of this type of cold mass support system

  6. Electrical phenomena in breaking the adhesive contact and in the destruction of solids. Development stages: From the gas discharge to cold nuclear fusion (on the 90th anniversary of the Academician of the Russian Academy of Sciences, B. V. Deryagin)

    International Nuclear Information System (INIS)

    Khrustalev, Yu.A.

    1993-01-01

    A brief review is presented of the research performed mainly by B. V. Deryagin and his coworkers into the electrophysical phenomena that accompany the breaking of an adhesive bond and of solids themselves by a mechanical action (the charging of fresh surfaces and gas discharge processes, caused by an excess charge, the emission of electrons and of x-ray radiation, as well as cold nuclear fusion). The relationship between the emission of electrons and mechanochemical processes in solids is pointed out. 118 refs

  7. Validation of cold chain during distribution of parenteral nutrition

    Directory of Open Access Journals (Sweden)

    Federico Tuan

    2015-09-01

    Full Text Available Objective: this study aims to demonstrate the suitability of the process used to condition the extemporaneous mixtures of parenteral nutrition for distribution, considering the objective of preserving the cold chain during transport until it reaches the patient, necessary to ensure stability, effectiveness and safety of these mixtures. Method: concurrent validation, design and implementation of a protocol for evaluating the process of packaging and distribution of MNPE developed by a pharmaceutical laboratory. Running tests, according to predefined acceptance criteria. It is performed twice, in summer and on routes that require longer transfer time. Evaluation of conservation of temperature by monitoring the internal temperature values of each type of packaging, recorded by data loggers calibrated equipment. Results: the different tests meet the established criteria. The collected data ensure the maintenance of the cold chain for longer than the transfer time to the most distant points. Conclusions: this study establishes the suitability of the processes to maintaining the cold chain for transfer from the laboratory to the patient pharmacist. Whereas the breaking of cold chain can cause changes of compatibility and stability of parenteral nutrition and failures nutritional support, this study contributes to patient safety, one of the relevant dimensions of quality of care the health.

  8. Collisional drag may lead to disappearance of wave-breaking phenomenon of lower hybrid oscillations

    International Nuclear Information System (INIS)

    Maity, Chandan; Chakrabarti, Nikhil

    2013-01-01

    The inhomogeneity in the magnetic field in a cold electron-ion non-dissipative homogeneous plasma leads to the breaking of lower hybrid modes via phase mixing phenomenon [Maity et al. Phys. Plasmas 19, 102302 (2012)]. In this work, we show that an inclusion of collisional drag force in fluid equations may lead to the disappearance of the wave-breaking phenomenon of lower hybrid oscillations. The nonlinear analysis in Lagrangian variables provides an expression for a critical value of damping rate, above which spikes in the plasma density profile may disappear. The critical damping rate depends on the perturbation and magnetic field inhomogeneity amplitudes as well as the ratio of the magnetic field inhomogeneity and perturbation scale lengths.

  9. Comet assay as a cold chain control tool

    International Nuclear Information System (INIS)

    Duarte, Renato Cesar

    2009-01-01

    Bearing in mind an ever more demanding market regarding the quality of food, it has been necessary to develop processes that meet the demands of consumers. Within the existing processes the cold chain and irradiation stand out. The cold chain comprises all the stages of conserving food from production, cooling, freezing, storing and transportation to the final consumer. Irradiation, as a means of conserving food, prolongs the shelf life, inhibits budding and reduces pathogenic contamination among other benefits. Is very important the identification of food degradation in function of failure on the processes which they were subjected. The comet assay is a screening test widely studied, considerate fast and with low cost. By the fact of the test identify breaks on the DNA, may be possible use the comet test on the control of cold chain failures that degrade de food. The labels and stamp, do not consider the previous food situation and indicate failures from the moment where they be placed in contact with the product. With the comet assay is possible to check the degradation that has occurred in liver chicken samples until the moment of comet's test realization. (author)

  10. RELAP-5/MOD 3.2 Assessment Using an 11% Upper Plenum Break Experiment in the PSB Facility

    Energy Technology Data Exchange (ETDEWEB)

    Paul D. Bayless

    2003-01-01

    The RELAP/MOD3.2 computer code has been assessed using an 11% upper plenum break experiment in the PSB test facility at the Electrogorsk Research and Engineering Center. This work was performed as part of the U.S. Department of Energy's International Nuclear Safety Program, and is part of the effort addressing the capability of the RELAP5/MOD3.2 code to model transients in Soviet-designed reactors. Designated VVER Standard Problem PSBV1, the test addressed several important phenomena related to VVER behavior that the code needs to simulate well. The code was judged to reasonably model the phenomena of two-phase flow natural circulation in the primary coolant system, asymmetric loop behavior, leak flow, loop seal clearance in the cold legs, heat transfer in a covered core, heat transfer in a partially covered core, pressurizer thermal-hydraulics, and integral system effects. The code was judged to be in minimal agreement with the experiment data for the mixture level and entrainment in the core, leading to a user recommendation to assess the sensitivity of transient calculations to the interphase drag modeling in the core. No judgments were made for the phenomena of phase separation without mixture level formation, mixture level and entrainment in the steam generators, pool formation in the upper plenum, or flow stratification in horizontal pipes because either the phenomenon did not occur in the test or there were insufficient measurements to characterize the behavior.

  11. Simulation and Analysis of Small Break LOCA for AP1000 Using RELAP5-MV and Its Comparison with NOTRUMP Code

    Directory of Open Access Journals (Sweden)

    Eltayeb Yousif

    2017-01-01

    Full Text Available Many reactor safety simulation codes for nuclear power plants (NPPs have been developed. However, it is very important to evaluate these codes by testing different accident scenarios in actual plant conditions. In reactor analysis, small break loss of coolant accident (SBLOCA is an important safety issue. RELAP5-MV Visualized Modularization software is recognized as one of the best estimate transient simulation programs of light water reactors (LWR. RELAP5-MV has new options for improved modeling methods and interactive graphics display. Though the same models incorporated in RELAP5/MOD 4.0 are in RELAP5-MV, the significant difference of the latter is the interface for preparing the input deck. In this paper, RELAP5-MV is applied for the transient analysis of the primary system variation of thermal hydraulics parameters in primary loop under SBLOCA in AP1000 NPP. The upper limit of SBLOCA (10 inches is simulated in the cold leg of the reactor and the calculations performed up to a transient time of 450,000.0 s. The results obtained from RELAP5-MV are in good agreement with those of NOTRUMP code obtained by Westinghouse when compared under the same conditions. It can be easily inferred that RELAP5-MV, in a similar manner to RELAP5/MOD4.0, is suitable for simulating a SBLOCA scenario.

  12. Effect of cold storage, heat, smoke and charcoal on breaking seed dormancy of Arctostaphylos pungens HBK (Ericaceae)

    OpenAIRE

    Jurado, E; Márquez-Linares, M; Flores, J

    2011-01-01

    We evaluated the effect of cold storage and fire-related cues on seed germination of Arctostaphylos pungens HBK (Mexican Manzanita), a common shrub in poorly managed pine-oak forests in Durango, Mexico. Because this shrub has a high density in previously burnt forests, we investigated the effect that high temperatures, smoke and charcoal might have on seed germination of this species. Seeds were collected fresh from the shrubs. The highest germination was 30% for seeds that had been cold stor...

  13. Thermal fluid mixing behavior during medium break LOCA in evaluation of pressurized thermal shock

    International Nuclear Information System (INIS)

    Jung, Jae Won; Bang, Young Seok; Seul, Kwang Won; Kim, Hho Jung

    1998-01-01

    Thermal fluid mixing behavior during a postulated medium-size hot leg break loss of coolant accident is analyzed for the international comparative assessment study on pressurized thermal shock (PTS-ICAS) proposed by OECD-NEA. the applicability of RELAP5 code to analyze the thermal fluid mixing behavior is evaluated through a simple modeling relevant to the problem constraints. Based on the calculation result, the onset of thermal stratification is investigated using Theofanous's empirical correlation. Sensitivity calculations using a fine node model and crossflow model are also performed to evaluate the modeling capability on multi-dimensional characteristics related to thermal fluid mixing

  14. Leg pain

    Science.gov (United States)

    ... in the blood Medicines (such as diuretics and statins) Muscle fatigue or strain from overuse, too much exercise, or holding a muscle in the same position for a long time An injury can also cause leg pain from: A torn or overstretched muscle ( strain ) Hairline ...

  15. Broken Leg

    Science.gov (United States)

    ... the leg, which can result in a fracture. Stress fractures outside of sport situations are more common in people who have: ... shoes. Choose the appropriate shoe for your favorite sports or activities. And ... can prevent stress fractures. Rotate running with swimming or biking. If ...

  16. Effects of Core Cavity on a Flow Distribution

    Energy Technology Data Exchange (ETDEWEB)

    Kwon, Tae-Soon; Kim, Kihwan [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2016-10-15

    The axial pressure drop is removed in the free core condition, But the actual core has lots of fuel bundles and mixing vanes to the flow direction. The axial pressure drop induces flow uniformity. In a uniform flow having no shear stress, the cross flow or cross flow mixing decreases. The mixing factor is important in the reactor safety during a Steam Line Break (SLB) or Main Steam Line Break (MSLB) transients. And the effect of core cavity is needed to evaluate the realistic core mixing factor quantification. The multi-dimensional flow mixing phenomena in a core cavity has been studied using a CFD code. The 1/5-scale model was applied for the reactor flow analysis. A single phase water flow conditions were considered for the 4-cold leg and DVI flows. To quantify the mixing intensity, a boron scalar was introduced to the ECC injection water at cold legs and DVI nozzles. The present CFD pre-study was performed to quantify the effects of core structure on the mixing phenomena. The quantified boron mixing scalar in the core simulator model represented the effect of core cavity on the core mixing phenomena. This simulation results also give the information for sensor resolution to measure the boron concentration in the experiments and response time to detect mixing phenomena at the core and reactor vessel.

  17. Nambu-Goldstone Fermion Mode in Quark-Gluon Plasma and Bose-Fermi Cold Atom System

    International Nuclear Information System (INIS)

    Satow, D.

    2015-01-01

    It was suggested that supersymmetry (SUSY) is broken at finite temperature, and as a result of the symmetry breaking, a Nambu-Goldstone fermion (goldstino) related to SUSY breaking appears. Since dispersion relations of quarks and gluons are almost degenerate at extremely high temperature, quasi-zero energy quark excitation was suggested to exist in quark-gluon plasma (QGP), though QCD does not have exact SUSY. On the other hand, in condensed matter system, a setup of cold atom system in which the Hamiltonian has SUSY was proposed, the goldstino was suggested to exist, and the dispersion relation of that mode at zero temperature was obtained recently. In this presentation, we obtain the expressions for the dispersion relation of the goldstino in cold atom system at finite temperature, and compare it with the dispersion of the quasi zero-mode in QGP. Furthermore, we show that the form of the dispersion relation of the goldstino can be understood by using an analogy with a magnon in ferromagnet. We also discuss on how the dispersion relation of the goldstino is reflected in observable quantities in experiment. (author)

  18. Not letting the left leg know what the right leg is doing: limb-specific locomotor adaptation to sensory-cue conflict.

    Science.gov (United States)

    Durgin, Frank H; Fox, Laura F; Hoon Kim, Dong

    2003-11-01

    We investigated the phenomenon of limb-specific locomotor adaptation in order to adjudicate between sensory-cue-conflict theory and motor-adaptation theory. The results were consistent with cue-conflict theory in demonstrating that two different leg-specific hopping aftereffects are modulated by the presence of conflicting estimates of self-motion from visual and nonvisual sources. Experiment 1 shows that leg-specific increases in forward drift during attempts to hop in place on one leg while blindfolded vary according to the relationship between visual information and motor activity during an adaptation to outdoor forward hopping. Experiment 2 shows that leg-specific changes in performance on a blindfolded hopping-to-target task are similarly modulated by the presence of cue conflict during adaptation to hopping on a treadmill. Experiment 3 shows that leg-specific aftereffects from hopping additionally produce inadvertent turning during running in place while blindfolded. The results of these experiments suggest that these leg-specific locomotor aftereffects are produced by sensory-cue conflict rather than simple motor adaptation.

  19. Natural X-ray lines from the low scale supersymmetry breaking

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Zhaofeng, E-mail: zhaofengkang@gmail.com [Center for High-Energy Physics, Peking University, Beijing 100871 (China); School of Physics, Korea Institute for Advanced Study, Seoul 130-722 (Korea, Republic of); Ko, P., E-mail: pko@kias.re.kr [School of Physics, Korea Institute for Advanced Study, Seoul 130-722 (Korea, Republic of); Li, Tianjun, E-mail: tli@itp.ac.cn [State Key Laboratory of Theoretical Physics and Kavli Institute for Theoretical Physics China (KITPC), Institute of Theoretical Physics, Chinese Academy of Sciences, Beijing 100190 (China); School of Physical Electronics, University of Electronic Science and Technology of China, Chengdu 610054 (China); Liu, Yandong, E-mail: ydliu@itp.ac.cn [State Key Laboratory of Theoretical Physics and Kavli Institute for Theoretical Physics China (KITPC), Institute of Theoretical Physics, Chinese Academy of Sciences, Beijing 100190 (China)

    2015-03-06

    In the supersymmetric models with low scale supersymmetry (SUSY) breaking where the gravitino mass is around keV, we show that the 3.5 keV X-ray lines can be explained naturally through several different mechanisms: (I) a keV scale dark gaugino plays the role of sterile neutrino in the presence of bilinear R-parity violation. Because the light dark gaugino obtains Majorana mass only via gravity mediation, it is a decaying warm dark matter (DM) candidate; (II) the compressed cold DM states, whose mass degeneracy is broken by gravity mediated SUSY breaking, emit such a line via the heavier one decay into the lighter one plus photon(s). A highly supersymmetric dark sector may readily provide such kind of system; (III) the light axino, whose mass again is around the gravitino mass, decays to neutrino plus gamma in the R-parity violating SUSY. Moreover, we comment on dark radiation from dark gaugino.

  20. Quantifying Leg Movement Activity During Sleep.

    Science.gov (United States)

    Ferri, Raffaele; Fulda, Stephany

    2016-12-01

    Currently, 2 sets of similar rules for recording and scoring leg movement (LM) exist, including periodic LM during sleep (PLMS) and periodic LM during wakefulness. The former were published in 2006 by a task force of the International Restless Legs Syndrome Study Group, and the second in 2007 by the American Academy of Sleep Medicine. This article reviews the basic recording methods, scoring rules, and computer-based programs for PLMS. Less frequent LM activities, such as alternating leg muscle activation, hypnagogic foot tremor, high-frequency LMs, and excessive fragmentary myoclonus are briefly described. Copyright © 2016 Elsevier Inc. All rights reserved.

  1. Large Break LOCA Analysis with New downcomer Nodalizaion and Multi-Dimensional Model and Effect of Cross flow option in MARS code

    Energy Technology Data Exchange (ETDEWEB)

    Jang, Hyung-wook; Lee, Sang-yong; Oh, Seung-jong; Kim, Woong-bae [KEPCO International Nuclear Graduate School, Ulsan (Korea, Republic of)

    2016-10-15

    The phenomena of LOCA have been investigated for long time. The most extensive research project for LOCA was the 2D/3D program experiments. The results of the 2D/3D experiments show flow conditions in the downcomer during end-of-blowdown were highly multi-dimensional at full-scale. In this paper, the authors modified the nodalization of MARS code LBLOCA input deck and performed LBLOCA analysis with new input deck. An LBLOCA analysis for APR1400 with new downcomer input deck was conducted using KREM with MARS-KS 1.4 Version code. Analysis was processed under LBCOCA of 100% break size of cold leg case. The authors developed input deck with new downcomer nodalizaion and Multi-Dimensional downcomer model, then implemented LOCA analysis with new input decks and compared with existing analysis results. PCT from new input and multi-dimensional input deck shows similar PCT trend from original input deck. There occurred more rapid drop of PCT from new and multidimensional input deck than original input deck. PCT from new and multidimensional input deck are satisfied with PCT design limit. It can be concluded that there occurs no acceptance criteria issue even though new and multidimensional input deck are applied to LBLOCA analysis. In future study, comparative analysis with experiment results will be implemented.

  2. Leg ulcers due to hyperhomocysteinemia

    Directory of Open Access Journals (Sweden)

    Krupa Shankar D

    2006-01-01

    Full Text Available Chronic leg ulcers are rare in young adults and generally indicate a vascular cause. We report a case of a 26-year-old man with leg ulcers of eight months duration. Doppler study indicated venous incompetence and a postphlebitic limb. However, as the distribution and number of ulcers was not consistent with stasis alone and no features of collagen vascular disease were noted, a hyperviscosity state was considered and confirmed with significantly elevated homocysteine level in the serum. Administration of vitamins B1, B2, B6 and B12, trimethyl-glycine, mecobalamine, folic acid and povidone iodine dressings with culture-directed antibiotic therapy led to a satisfactory healing of ulcers over a period of one month. Hyperhomocysteinemia must be considered in the differential diagnosis of leg ulcers in young individuals.

  3. Thermohydraulic analysis of nuclear power plant accidents by computer codes

    International Nuclear Information System (INIS)

    Petelin, S.; Stritar, A.; Istenic, R.; Gregoric, M.; Jerele, A.; Mavko, B.

    1982-01-01

    RELAP4/MOD6, BRUCH-D-06, CONTEMPT-LT-28, RELAP5/MOD1 and COBRA-4-1 codes were successful y implemented at the CYBER 172 computer in Ljubljana. Input models of NPP Krsko for the first three codes were prepared. Because of the high computer cost only one analysis of double ended guillotine break of the cold leg of NPP Krsko by RELAP4 code has been done. BRUCH code is easier and cheaper for use. Several analysis have been done. Sensitivity study was performed with CONTEMPT-LT-28 for double ended pump suction break. These codes are intended to be used as a basis for independent safety analyses. (author)

  4. Application of RELAP5/MOD3.1 code to the LOFT test L3-6

    International Nuclear Information System (INIS)

    Pylev, S.S.; Roginskaja, V.L.

    1998-02-01

    A calculation of LOFT Experiment L3-6, a small break equivalent to a 4-in diameter rupture in the cold leg of a four-loop commercial pressurized water reactor, has been performed to help validate RELAP5/MOD3.1 for this application. The version of the code to be used is SCDAP/RELAP5/MOD3.1.8d0. Three calculations were carried out in order to study the sensitivity to change break nozzle superheated discharge coefficient. Conducted comparative analysis of the LOFT L3-6 experiment shows on the whole a reasonable agreement between calculated data. Some discrepancies in the system pressure do not distort a picture of the transient. 6 refs

  5. Application of RELAP5/MOD3.1 code to the LOFT test L3-6

    Energy Technology Data Exchange (ETDEWEB)

    Pylev, S.S.; Roginskaja, V.L.

    1998-02-01

    A calculation of LOFT Experiment L3-6, a small break equivalent to a 4-in diameter rupture in the cold leg of a four-loop commercial pressurized water reactor, has been performed to help validate RELAP5/MOD3.1 for this application. The version of the code to be used is SCDAP/RELAP5/MOD3.1.8d0. Three calculations were carried out in order to study the sensitivity to change break nozzle superheated discharge coefficient. Conducted comparative analysis of the LOFT L3-6 experiment shows on the whole a reasonable agreement between calculated data. Some discrepancies in the system pressure do not distort a picture of the transient. 6 refs.

  6. The applicability of CFD to simulate and study the mixing process and the thermo-hydraulic consequences of a main steam line break in PWR model

    Directory of Open Access Journals (Sweden)

    Farkas Istvan

    2017-01-01

    Full Text Available This paper focuses on the validation and applicability of CFD to simulate and analyze the thermo-hydraulic consequences of a main steam line break. Extensive validation data come from experiments performed using the Rossendorf coolant mixing model facility. For the calculation, the range of 9 to 12 million hexahe¬dral cells was constructed to capture all details in the interrogation domain in the system. The analysis was performed by running a time-dependent calculation, Detailed analyses were made at different cross-sections in the system to evaluate not only the value of the maximum and minimum temperature, but also the loca¬tion and the time at which it occurs during the transient which is considered to be indicator for the quality of mixing in the system. CFD and experimental results were qualitatively compared; mixing in the cold legs with emergency core cooling systems was overestimated. This could be explained by the sensitivity to the bound¬ary conditions. In the downcomer, the experiments displayed higher mixing: by our assumption this related to the dense measurement grid (they were not modelled. The temperature distribution in the core inlet plane agreed with the measurement results. Minor deviations were seen in the quantitative comparisons: the maximum temperature difference was 2ºC.

  7. Bioinspired template-based control of legged locomotion

    OpenAIRE

    Ahmad Sharbafi, Maziar

    2018-01-01

    cient and robust locomotion is a crucial condition for the more extensive use of legged robots in real world applications. In that respect, robots can learn from animals, if the principles underlying locomotion in biological legged systems can be transferred to their artificial counterparts. However, legged locomotion in biological systems is a complex and not fully understood problem. A great progress to simplify understanding locomotion dynamics and control was made by introducing simple mo...

  8. Six weeks' aerobic retraining after two weeks' immobilization restores leg lean mass and aerobic capacity but does not fully rehabilitate leg strenght in young and older men

    DEFF Research Database (Denmark)

    Vigelsø Hansen, Andreas; Gram, Martin; Wiuff, Caroline

    2015-01-01

    OBJECTIVE: To determine the effect of aerobic retraining as rehabilitation after short-term leg immobilization on leg strength, leg work capacity, leg lean mass, leg muscle fibre type composition and leg capillary supply, in young and older men. SUBJECTS AND DESIGN: Seventeen young (23 ± 1 years...... immobilization had marked effects on leg strength, and work capacity and 6 weeks' retraining was sufficient to increase, but not completely rehabilitate, muscle strength, and to rehabilitate aerobic work capacity and leg lean mass (in the young men)....

  9. LBLOCA sensitivity analysis using meta models

    International Nuclear Information System (INIS)

    Villamizar, M.; Sanchez-Saez, F.; Villanueva, J.F.; Carlos, S.; Sanchez, A.I.; Martorell, S.

    2014-01-01

    This paper presents an approach to perform the sensitivity analysis of the results of simulation of thermal hydraulic codes within a BEPU approach. Sensitivity analysis is based on the computation of Sobol' indices that makes use of a meta model, It presents also an application to a Large-Break Loss of Coolant Accident, LBLOCA, in the cold leg of a pressurized water reactor, PWR, addressing the results of the BEMUSE program and using the thermal-hydraulic code TRACE. (authors)

  10. Adaptive leg coordination with a biologically inspired neurocontroller

    Science.gov (United States)

    Braught, Grant; Thomopoulos, Stelios C.

    1996-10-01

    Natural selection is responsible for the creation of robust and adaptive control systems. Nature's control systems are created only from primitive building blocks. Using insect neurophysiology as a guide, a neural architecture for leg coordination in a hexapod robot has been developed. Reflex chains and sensory feedback mechanisms from various insects and crustacea form the basis of a pattern generator for intra-leg coordination. The pattern generator contains neural oscillators which learn from sensory feedback to produce stepping patterns. Using sensory feedback as the source of learning information allows the pattern generator to adapt to changes in the leg dynamics due to internal or external causes. A coupling between six of the single leg pattern generators is used to produce the inter-leg coordination necessary to establish stable gaits.

  11. Proteome analysis of Norway maple (Acer platanoides L.) seeds dormancy breaking and germination: influence of abscisic and gibberellic acids.

    Science.gov (United States)

    Pawłowski, Tomasz A

    2009-05-04

    Seed dormancy is controlled by the physiological or structural properties of a seed and the external conditions. It is induced as part of the genetic program of seed development and maturation. Seeds with deep physiological embryo dormancy can be stimulated to germinate by a variety of treatments including cold stratification. Hormonal imbalance between germination inhibitors (e.g. abscisic acid) and growth promoters (e.g. gibberellins) is the main cause of seed dormancy breaking. Differences in the status of hormones would affect expression of genes required for germination. Proteomics offers the opportunity to examine simultaneous changes and to classify temporal patterns of protein accumulation occurring during seed dormancy breaking and germination. Analysis of the functions of the identified proteins and the related metabolic pathways, in conjunction with the plant hormones implicated in seed dormancy breaking, would expand our knowledge about this process. A proteomic approach was used to analyse the mechanism of dormancy breaking in Norway maple seeds caused by cold stratification, and the participation of the abscisic (ABA) and gibberellic (GA) acids. Forty-four proteins showing significant changes were identified by mass spectrometry. Of these, eight spots were identified as water-responsive, 18 spots were ABA- and nine GA-responsive and nine spots were regulated by both hormones. The classification of proteins showed that most of the proteins associated with dormancy breaking in water were involved in protein destination. Most of the ABA- and GA-responsive proteins were involved in protein destination and energy metabolism. In this study, ABA was found to mostly down-regulate proteins whereas GA up-regulated proteins abundance. Most of the changes were observed at the end of stratification in the germinated seeds. This is the most active period of dormancy breaking when seeds pass from the quiescent state to germination. Seed dormancy breaking involves

  12. Proteome analysis of Norway maple (Acer platanoides L. seeds dormancy breaking and germination: influence of abscisic and gibberellic acids

    Directory of Open Access Journals (Sweden)

    Pawłowski Tomasz A

    2009-05-01

    Full Text Available Abstract Background Seed dormancy is controlled by the physiological or structural properties of a seed and the external conditions. It is induced as part of the genetic program of seed development and maturation. Seeds with deep physiological embryo dormancy can be stimulated to germinate by a variety of treatments including cold stratification. Hormonal imbalance between germination inhibitors (e.g. abscisic acid and growth promoters (e.g. gibberellins is the main cause of seed dormancy breaking. Differences in the status of hormones would affect expression of genes required for germination. Proteomics offers the opportunity to examine simultaneous changes and to classify temporal patterns of protein accumulation occurring during seed dormancy breaking and germination. Analysis of the functions of the identified proteins and the related metabolic pathways, in conjunction with the plant hormones implicated in seed dormancy breaking, would expand our knowledge about this process. Results A proteomic approach was used to analyse the mechanism of dormancy breaking in Norway maple seeds caused by cold stratification, and the participation of the abscisic (ABA and gibberellic (GA acids. Forty-four proteins showing significant changes were identified by mass spectrometry. Of these, eight spots were identified as water-responsive, 18 spots were ABA- and nine GA-responsive and nine spots were regulated by both hormones. The classification of proteins showed that most of the proteins associated with dormancy breaking in water were involved in protein destination. Most of the ABA- and GA-responsive proteins were involved in protein destination and energy metabolism. Conclusion In this study, ABA was found to mostly down-regulate proteins whereas GA up-regulated proteins abundance. Most of the changes were observed at the end of stratification in the germinated seeds. This is the most active period of dormancy breaking when seeds pass from the quiescent

  13. LOFT/LP-LB-1, Loss of Fluid Test, Large-Break LOCA Experiment

    International Nuclear Information System (INIS)

    1989-01-01

    1 - Description of test facility: The LOFT Integral Test Facility is a scale model of a LPWR. The intent of the facility is to model the nuclear, Thermal-hydraulic phenomena which would take place in a LPWR during a LOCA. The general philosophy in scaling coolant volumes and flow areas in LOFT was to use the ratio of the LOFT core [50 MW(t)] to a typical LPWR core [3000 MW(t)]. For some components, this factor is not applied; however, it is used as extensively as practical. In general, components used in LOFT are similar in design to those of a LPWR. Because of scaling and component design, the LOFT LOCE is expected to closely model a LPWR LOCA. 2 - Description of test: Experiment LP-LB-1 was conducted on 3 February 1984 in the Loss-of-Fluid Test (LOFT) facility at the Idaho National Engineering Laboratory under the auspices of the Organization for Economic Cooperation and Development. The primary objectives of Experiment LP-LB-1 were to determine system transient characteristics and to assess code predictive capabilities for design basis large-break loss-of-coolant accidents in pressurized water reactors (PWRs). This experiment simulated a double-ended offset shear of one inlet pipe in a four-loop PWR and was initiated from conditions representative of licensing limits in a PWR. Other boundary conditions for the simulation were loss of offsite power, rapid primary coolant pump coast down, and United Kingdom minimum safeguard emergency core coolant injection rates. The nuclear fuel rods were not pressurized. The transient was initiated by opening the quick-opening blowdown valves in the broken loop hot and cold legs. 3 - Experimental limitations or shortcomings: Short core and steam generator, excessive core bypass, other scaling compromises, and lack of adequate measurements in certain areas

  14. Detection of cold pain, cold allodynia and cold hyperalgesia in freely behaving rats

    Directory of Open Access Journals (Sweden)

    Woolf Clifford J

    2005-12-01

    Full Text Available Abstract Background Pain is elicited by cold, and a major feature of many neuropathic pain states is that normally innocuous cool stimuli begin to produce pain (cold allodynia. To expand our understanding of cold induced pain states we have studied cold pain behaviors over a range of temperatures in several animal models of chronic pain. Results We demonstrate that a Peltier-cooled cold plate with ± 1°C sensitivity enables quantitative measurement of a detection withdrawal response to cold stimuli in unrestrained rats. In naïve rats the threshold for eliciting cold pain behavior is 5°C. The withdrawal threshold for cold allodynia is 15°C in both the spared nerve injury and spinal nerve ligation models of neuropathic pain. Cold hyperalgesia is present in the spared nerve injury model animals, manifesting as a reduced latency of withdrawal response threshold at temperatures that elicit cold pain in naïve rats. We also show that following the peripheral inflammation produced by intraplantar injection of complete Freund's adjuvant, a hypersensitivity to cold occurs. Conclusion The peltier-cooled provides an effective means of assaying cold sensitivity in unrestrained rats. Behavioral testing of cold allodynia, hyperalgesia and pain will greatly facilitate the study of the neurobiological mechanisms involved in cold/cool sensations and enable measurement of the efficacy of pharmacological treatments to reduce these symptoms.

  15. Blowdown and rewetting characteristics for AHWR under postulated LOCA - an analytical study

    International Nuclear Information System (INIS)

    Mukhopadhyay, D.; Chatterjee, B.

    2015-01-01

    Advanced Heavy Water Reactor (AHWR) is a thorium fuelled, natural circulation driven and heavy water moderated reactor. The cooling of the nuclear fuel is achieved through natural circulation mode for the tube type reactor where hot and cold leg of the reactor has been designed to be long and high enough to avail the gravity head desired to overcome the hydraulic resistances in the flow path. The natural circulation cooling mode makes AHWR very different as compared to other tube type reactors with forced circulation e.g RBMK. This cooling feature which calls for longer pipes length and elevation head is having an influence on the blowdown characteristic and the initial fuel heatup characteristic of the reactor. Analyses of Loss of Coolant Accident carried out for different break sizes in the inlet header of the reactor identifies two competing transient forces namely 'blowdown force' and 'natural circulation' which act against each other due to virtue of the break location. The flow in the reactor channel is being decided by these two forces and eventually the flow condition decides the fuel heatup. It has been observed through analyses that variation of break sizes from moving smaller break sizes to bigger one (30% to 200%), causes an enhancement in blowdown forces and weakening of driving force for natural circulation as quality appears in cold leg section. A balance of these two forces is observed for 200% break case, causing a sustained flow stagnation condition leading to maximum fuel heat up among all the break cases. The blowdown characterization study is being carried out with RELAP5/mod3.4 code and the influences of transient forces on the fuel heatup are presented. It is concluded that the fuel heat up during blowdown phase is significantly dependent on the two competing forces namely blowdown and natural circulation which eventually depend on break sizes. The mist flow regime remains for a longer period during rewetting phase and the

  16. Børns leg og eksperimenterende virksomhed

    DEFF Research Database (Denmark)

    Damgaard Warrer, Sarah; Broström, Stig

    Børns leg og eksperimenterende virksomhed er et rigt felt med mange perspektiver, indgangsvinkler og nuancer. I denne bog kædes leg og det eksperimenterende og skabende sammen som to gensidigt forbundne fænomener og belyses i pædagogisk og didaktisk perspektiv. Desuden beskrives potentialet i båd...

  17. Restless Legs Syndrome -- Self-Tests and Diagnosis

    Science.gov (United States)

    ... legs syndrome Diagnosis Talk to a board certified sleep medicine physician if you think you have restless legs ... He or she can refer you to a sleep medicine physician if necessary. The sleep physician may ask ...

  18. Six-legged walking robot for service operations

    OpenAIRE

    Ihme, T.; Schneider, A.; Schmucker, U.

    1998-01-01

    This paper presents the control system of a six-legged vehicle including force control. Considered control schemes are control of forces and control of body motion. The experimental result with a six-legged robot is presented.

  19. Sensitivity of sensor-based sit-to-stand peak power to the effects of training leg strength, leg power and balance in older adults.

    Science.gov (United States)

    Regterschot, G Ruben H; Folkersma, Marjanne; Zhang, Wei; Baldus, Heribert; Stevens, Martin; Zijlstra, Wiebren

    2014-01-01

    Increasing leg strength, leg power and overall balance can improve mobility and reduce fall risk. Sensor-based assessment of peak power during the sit-to-stand (STS) transfer may be useful for detecting changes in mobility and fall risk. Therefore, this study investigated whether sensor-based STS peak power and related measures are sensitive to the effects of increasing leg strength, leg power and overall balance in older adults. A further aim was to compare sensitivity between sensor-based STS measures and standard clinical measures of leg strength, leg power, balance, mobility and fall risk, following an exercise-based intervention. To achieve these aims, 26 older adults (age: 70-84 years) participated in an eight-week exercise program aimed at improving leg strength, leg power and balance. Before and after the intervention, performance on normal and fast STS transfers was evaluated with a hybrid motion sensor worn on the hip. In addition, standard clinical tests (isometric quadriceps strength, Timed Up and Go test, Berg Balance Scale) were performed. Standard clinical tests as well as sensor-based measures of peak power, maximal velocity and duration of normal and fast STS showed significant improvements. Sensor-based measurement of peak power, maximal velocity and duration of normal STS demonstrated a higher sensitivity (absolute standardized response mean (SRM): ≥ 0.69) to the effects of training leg strength, leg power and balance than standard clinical measures (absolute SRM: ≤ 0.61). Therefore, the presented sensor-based method appears to be useful for detecting changes in mobility and fall risk. Copyright © 2013 Elsevier B.V. All rights reserved.

  20. Thermal fluid mixing behavior during medium break LOCA in evaluation of pressurized thermal shock

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Jae Won; Bang, Young Seok; Seul, Kwang Won; Kim, Hho Jung [Korea Institute of Nuclear Safety, Taejon (Korea, Republic of)

    1998-12-31

    Thermal fluid mixing behavior during a postulated medium-size hot leg break loss of coolant accident is analyzed for the international comparative assessment study on pressurized thermal shock (PTS-ICAS) proposed by OECD-NEA. The applicability of RELAP5 code to analyze the thermal fluid mixing behavior is evaluated through a simple modeling relevant to the problem constraints. Based on the calculation result, the onset of thermal stratification is investigated using Theofanous`s empirical correlation. Sensitivity calculations using a fine node model and crossflow model are also performed to evaluate the modeling capability on multi-dimensional characteristics related to thermal fluid mixing. 6 refs., 8 figs. (Author)

  1. Improving venous leg ulcer management

    OpenAIRE

    Weller, Carolina Dragica

    2017-01-01

    This thesis reports several different methods to develop and evaluate complex interventions designed to improve venous leg ulcer management. Chronic venous leg ulcers (VLU) are the most common chronic wound problem in the community. Its health and economic burden is predicted to increase due to ageing of the community and increase in prevalence of diabetes and obesity. Although many patients seek health care for VLU, most do not receive the most effective management. Patients with this condi...

  2. Assessing Children's Legs and Feet

    OpenAIRE

    Wedge, John H.

    1985-01-01

    Shoes are necessary for protection and warmth. Normal children do not require shoes for support. There is no scientific evidence that shoes—‘orthopedic’ or otherwise—influence or alter the growth or shape of the normal child's foot except, perhaps, adversely if they fit poorly. Family physicians must understand common variations of normal foot and leg development if they are to effectively advise and reassure parents about appropriate footwear. Flat feet, knock knees, bow legs, in-toeing, and...

  3. Promethus Hot Leg Piping Concept

    International Nuclear Information System (INIS)

    AM Girbik; PA Dilorenzo

    2006-01-01

    The Naval Reactors Prime Contractor Team (NRPCT) recommended the development of a gas cooled reactor directly coupled to a Brayton energy conversion system as the Space Nuclear Power Plant (SNPP) for NASA's Project Prometheus. The section of piping between the reactor outlet and turbine inlet, designated as the hot leg piping, required unique design features to allow the use of a nickel superalloy rather than a refractory metal as the pressure boundary. The NRPCT evaluated a variety of hot leg piping concepts for performance relative to SNPP system parameters, manufacturability, material considerations, and comparison to past high temperature gas reactor (HTGR) practice. Manufacturability challenges and the impact of pressure drop and turbine entrance temperature reduction on cycle efficiency were discriminators between the piping concepts. This paper summarizes the NRPCT hot leg piping evaluation, presents the concept recommended, and summarizes developmental issues for the recommended concept

  4. RESTLESS LEGS SYNDROME

    Directory of Open Access Journals (Sweden)

    Dmitriy Valer'evich Artem'ev

    2009-01-01

    Full Text Available The paper describes the epidemiology, etiology, pathogenesis, clinical picture, diagnosis, differential diagnosis, and treatment of restless legs syndrome. Recommendations are given how to choose therapeutic modalities and drugs in relation to different factors.

  5. Small break loss of coolant accidents: Bottom and side break

    International Nuclear Information System (INIS)

    Hardy, P.G.; Richter, H.J.

    1987-01-01

    A LOCA can be caused, e.g. by a small break in the primary cooling system. The rate of fluid escaping through such a break will define the time until the core will be uncovered. Therefore the prediction of fluid loss and pressure transient is of major importance to plan for timely action in response to such an event. Stratification of the two phases might be present upstream of the break, thus, the location of the break relative to the vapor-liquid interface and the overall upstream fluid conditions are relevant for the calculation of fluid loss. Experimental results and analyses are presented here for small breaks at the bottom or at the side of a small pressure vessel. It was found that in such a case the onset of the so-called ''vapor pull through'' is important but swelling at sufficient depressurization rates of the liquid due to flashing is also of significance. It was also discovered that in the bottom break the flow rate is strongly dependent on the break entrance quality of the vapour-liquid mixture. The side break can be treated similarly to the bottom break if the interface level is above the break. The analyses developed on the basis of experimental observations showed reasonable agreement of predicted and measured pressure transients. It was possible to calculate the changing interface level and mixture void fraction history in a way compatible with the behavior observed during the experiments. Even though the experiments were performed at low pressures, this work should help to get a better understanding of physical phenomena occurring in a full scale small break LOCA. (orig./HP)

  6. Protection against high intravascular pressure in giraffe legs

    DEFF Research Database (Denmark)

    Petersen, Karin K; Hørlyck, Arne; Østergaard, Kristine Hovkjær

    2013-01-01

    The high blood pressure in giraffe leg arteries renders giraffes vulnerable to edema. We investigated in 11 giraffes whether large and small arteries in the legs and the tight fascia protect leg capillaries. Ultrasound imaging of foreleg arteries in anesthetized giraffes and ex vivo examination....... All three findings can contribute to protection of the capillaries in giraffe legs from a high arterial pressure....... revealed abrupt thickening of the arterial wall and a reduction of its internal diameter just below the elbow. At and distal to this narrowing, the artery constricted spontaneously and in response to norepinephrine and intravascular pressure recordings revealed a dynamic, viscous pressure drop along...

  7. Experiment data report for LOFT nonnuclear Test L1-4

    International Nuclear Information System (INIS)

    Batt, D.L.

    1977-07-01

    Test L1-4 was the fourth in a series of five nonnuclear isothermal blowdown tests conducted by the Loss of Fluid Test (LOFT) Program. Test L1-4 was the first Nuclear Regulatory Commission standard problem (International Problem No. 5 and U.S. Problem No. 7) experiment conducted at LOFT. Data from this test will be compared with predictions generated by the standard problem participants. For this test the LOFT Facility was configured to simulate a loss-of-coolant accident in a large pressurized water reactor resulting from a 200% double-ended offset shear break in a cold leg of the primary coolant system. A hydraulic core simulator assembly was installed in place of the nuclear core. The initial conditions in the primary coolant system intact loop were temperature at 279 0 C, gauge pressure at 15.65 MPa, and intact loop flow at 268.4 kg/s. During system depressurization into a simulated containment, emergency core cooling water was injected into the primary coolant system cold leg to provide data on the effects of emergency core cooling on system thermalhydraulic response

  8. Data report for ROSA-IV LSTF gravity-driven safety injection experiment run SB-CL-27

    International Nuclear Information System (INIS)

    Yonomoto, Taisuke; Saitou, Seishi; Kuroda, Takeshi

    1994-03-01

    Experimental data are presented for the passive injection test, Run SB-CL-27, conducted at the ROSA-IV Large Scale Test Facility (LSTF) on September 17, 1992. This experiment simulated thermal-hydraulic behavior of a gravity-driven, passive safety injection system during a small-break loss-of-coolant accident (LOCA) in a pressurized water reactor (PWR). The injection system consisted of a gravity-driven injection tank, located above the reactor vessel, with connecting lines. The tank was initially filled with water of room temperature at the same pressure as the pressurizer. The connecting lines to the cold leg and to the vessel downcomer were opened at the test initiation. Then, a natural circulation flow developed in the loop which was formed by these lines and the injection tank. The hot water in the cold leg circulated into the upper part of tank and accumulated there causing a significant thermal stratification. This thermal stratification prevented direct-contact condensation of steam from occurring during the subsequent tank drain-down phase. Therefore, no condensation-induced depressurization of the tank, affecting adversely the injection performance, occurred. (author)

  9. Skipping on uneven ground: trailing leg adjustments simplify control and enhance robustness.

    Science.gov (United States)

    Müller, Roy; Andrada, Emanuel

    2018-01-01

    It is known that humans intentionally choose skipping in special situations, e.g. when descending stairs or when moving in environments with lower gravity than on Earth. Although those situations involve uneven locomotion, the dynamics of human skipping on uneven ground have not yet been addressed. To find the reasons that may motivate this gait, we combined experimental data on humans with numerical simulations on a bipedal spring-loaded inverted pendulum model (BSLIP). To drive the model, the following parameters were estimated from nine subjects skipping across a single drop in ground level: leg lengths at touchdown, leg stiffness of both legs, aperture angle between legs, trailing leg angle at touchdown (leg landing first after flight phase), and trailing leg retraction speed. We found that leg adjustments in humans occur mostly in the trailing leg (low to moderate leg retraction during swing phase, reduced trailing leg stiffness, and flatter trailing leg angle at lowered touchdown). When transferring these leg adjustments to the BSLIP model, the capacity of the model to cope with sudden-drop perturbations increased.

  10. An Overall Investigation of Direct Vessel Injection Line Break Accidents of the ATLAS Facility

    International Nuclear Information System (INIS)

    Kim, Yeon-Sik; Choi, Ki-Yong; Cho, Seok; Kim, Bok-Deuk

    2015-01-01

    For parametric evaluations of direct vessel injection (DVI) line break scenarios, the pressurizer (PZR) pressure, core collapsed water level, and peak cladding temperature were investigated between the analyses and tests. The PZR pressure was mainly dependent upon the break flow model, e.g., discharge coefficient of the Henry-Fauske critical model. The core collapsed water level and peak cladding temperature were mainly dependent on the counter-current flow limit (CCFL) option of the fuel alignment plate (FAP). The CCFL option of the cross-over leg (COL) affected the PZR pressure owing to the loop seal clearings and seemed to have little effect on the core collapsed water level. Proper C d values and applicable CCFL options were summarized. C d values seemed to be dependent on the sizes of the DVI line break. The PZR pressure was mainly dependent on the break flow model, e.g., the discharge coefficient of the Henry-Fauske critical model. The core collapsed water level and peak cladding temperature were mainly dependent on the CCFL option of the FAP. The CCFL option of the COL affected the PZR pressure owing to loop seal clearings and seemed to have little effect on the core collapsed water level. From parametric evaluations, proper C d values and applicable CCFL options were suggested. The C d values seemed to be dependent on the sizes of the DVI line break. Although there was little difference in the CCFL options of the COL, the Ku-option was the preferred one for COLs' CCFL option. The CCFL options of the FAP appeared sensitive to the core collapsed water level and peak cladding temperature. The Ku-option of the FAP tended to negatively exaggerate the core behavior and showed excessively conservative results, especially on the peak cladding temperature. For smaller breaks, e.g., 25%, NA- and Wa-options would be applicable for the FAP. However, for larger breaks, e.g., 50%, the Wa-option of the FAP was the preferred one. Comparisons between the tests and

  11. Simulation of accident and restrained transients in PWR nuclear power plant with RELAP 5/MOD 1 computer code

    International Nuclear Information System (INIS)

    Silva Filho, E.

    1986-01-01

    The computer code RELAP5/MOD1 has been utilized to investigate the thermal-hydraulic behaviour of a standard 1300 Mwe pressurized water reactor plant of the KWU design during a station blackout and during a loss-of-coolant accident involving 2% break in the cross-sectional area the cold leg in one of the four loops and located between the pump and the reactor pressure vessel. During the simulations the reactor scram system and the emergency coolant system were considered inactive. (Author) [pt

  12. Give me a better break: Choosing workday break activities to maximize resource recovery.

    Science.gov (United States)

    Hunter, Emily M; Wu, Cindy

    2016-02-01

    Surprisingly little research investigates employee breaks at work, and even less research provides prescriptive suggestions for better workday breaks in terms of when, where, and how break activities are most beneficial. Based on the effort-recovery model and using experience sampling methodology, we examined the characteristics of employee workday breaks with 95 employees across 5 workdays. In addition, we examined resources as a mediator between break characteristics and well-being. Multilevel analysis results indicated that activities that were preferred and earlier in the work shift related to more resource recovery following the break. We also found that resources mediated the influence of preferred break activities and time of break on health symptoms and that resource recovery benefited person-level outcomes of emotional exhaustion, job satisfaction, and organizational citizenship behavior. Finally, break length interacted with the number of breaks per day such that longer breaks and frequent short breaks were associated with more resources than infrequent short breaks. (c) 2016 APA, all rights reserved).

  13. A swath across the great divide: Kelp forests across the Samalga Pass biogeographic break

    Science.gov (United States)

    Konar, Brenda H.; Edwards, Matthew S.; Bland, Aaron; Metzger, Jacob; Ravelo, Alexandra; Traiger, Sarah; Weitzman, Ben P.

    2017-01-01

    Biogeographic breaks are often described as locations where a large number of species reach their geographic range limits. Samalga Pass, in the eastern Aleutian Archipelago, is a known biogeographic break for the spatial distribution of several species of offshore-pelagic communities, including numerous species of cold-water corals, zooplankton, fish, marine mammals, and seabirds. However, it remains unclear whether Samalga Pass also serves as a biogeographic break for nearshore benthic communities. The occurrence of biogeographic breaks across multiple habitats has not often been described. In this study, we examined if the biogeographic break for offshore-pelagic communities applies to nearshore kelp forests. To examine whether Samalga Pass serves as a biogeographic break for kelp forest communities, this study compared abundance, biomass and percent bottom cover of species associated with kelp forests on either side of the pass. We observed marked differences in kelp forest community structure, with some species reaching their geographic range limits on the opposing sides of the pass. In particular, the habitat-forming kelp Nereocystis luetkeana, and the predatory sea stars Pycnopodia helianthoides and Orthasterias koehleri all occurred on the eastern side of Samalga Pass but were not observed west of the pass. In contrast, the sea star Leptasterias camtschatica dispar was observed only on the western side of the pass. We also observed differences in overall abundance and biomass of numerous associated fish, invertebrate and macroalgal species on opposing sides of the pass. We conclude that Samalga Pass is important biogeographic break for kelp forest communities in the Aleutian Archipelago and may demark the geographic range limits of several ecologically important species.

  14. Bio-Inspired Design and Kinematic Analysis of Dung Beetle-Like Legs

    DEFF Research Database (Denmark)

    Aditya, Sai Krishna Venkata; Ignasov, Jevgeni; Filonenko, Konstantin

    2017-01-01

    The African dung beetle Scarabaeus galenus can use its front legs to walk and manipulate or form a dung ball. The interesting multifunctional legs have not been fully investigated or even used as inspiration for robot leg design. Thus, in this paper, we present the development of real dung beetle......-like front legs based on biological investigation. As a result, each leg consists of three main segments which were built using 3D printing. The segments were combined with in total four active DOFs in order to mimic locomotion and object manipulation of the beetle. Kinematics analysis of the leg was also...... performed to identify its workspace as well as to design its trajectory. To this end, the study contributes not only novel multifunctional robotic legs but also the methodology of the bio-inspired leg design....

  15. Effect of cold water immersion on repeated cycling performance and limb blood flow.

    Science.gov (United States)

    Vaile, J; O'Hagan, C; Stefanovic, B; Walker, M; Gill, N; Askew, C D

    2011-08-01

    The purpose of the present study was to compare the effects of cold water immersion (CWI) and active recovery (ACT) on resting limb blood flow, rectal temperature and repeated cycling performance in the heat. Ten subjects completed two testing sessions separated by 1 week; each trial consisted of an initial all-out 35-min exercise bout, one of two 15-min recovery interventions (randomised: CWI or ACT), followed by a 40-min passive recovery period before repeating the 35-min exercise bout. Performance was measured as the change in total work completed during the exercise bouts. Resting limb blood flow, heart rate, rectal temperature and blood lactate were recorded throughout the testing sessions. There was a significant decline in performance after ACT (mean (SD) -1.81% (1.05%)) compared with CWI where performance remained unchanged (0.10% (0.71%)). Rectal temperature was reduced after CWI (36.8°C (1.0°C)) compared with ACT (38.3°C (0.4°C)), as was blood flow to the arms (CWI 3.64 (1.47) ml/100 ml/min; ACT 16.85 (3.57) ml/100 ml/min) and legs (CW 4.83 (2.49) ml/100 ml/min; ACT 4.83 (2.49) ml/100 ml/min). Leg blood flow at the end of the second exercise bout was not different between the active (15.25 (4.33) ml/100 ml/min) and cold trials (14.99 (4.96) ml/100 ml/min), whereas rectal temperature (CWI 38.1°C (0.3°C); ACT 38.8°C (0.2°C)) and arm blood flow (CWI 20.55 (3.78) ml/100 ml/min; ACT 23.83 (5.32) ml/100 ml/min) remained depressed until the end of the cold trial. These findings indicate that CWI is an effective intervention for maintaining repeat cycling performance in the heat and this performance benefit is associated with alterations in core temperature and limb blood flow.

  16. Breaking Bat

    Science.gov (United States)

    Aguilar, Isaac-Cesar; Kagan, David

    2013-01-01

    The sight of a broken bat in Major League Baseball can produce anything from a humorous dribbler in the infield to a frightening pointed projectile headed for the stands. Bats usually break at the weakest point, typically in the handle. Breaking happens because the wood gets bent beyond the breaking point due to the wave sent down the bat created…

  17. Clinical quality indicators of venous leg ulcers

    DEFF Research Database (Denmark)

    Kjaer, Monica L; Mainz, Jan; Soernsen, Lars T

    2005-01-01

    In the clinical setting, diagnosis and treatment of venous leg ulcers can vary considerably from patient to patient. The first step to reducing this variation is to document venous leg ulcer care through use of quantitative scientific documentation principles. This requires the development of val...

  18. Ubx regulates differential enlargement and diversification of insect hind legs.

    Directory of Open Access Journals (Sweden)

    Najmus Mahfooz

    2007-09-01

    Full Text Available Differential enlargement of hind (T3 legs represents one of the hallmarks of insect evolution. However, the actual mechanism(s responsible are yet to be determined. To address this issue, we have now studied the molecular basis of T3 leg enlargement in Oncopeltus fasciatus (milkweed bug and Acheta domesticus (house cricket. In Oncopeltus, the T3 tibia displays a moderate increase in size, whereas in Acheta, the T3 femur, tibia, and tarsus are all greatly enlarged. Here, we show that the hox gene Ultrabithorax (Ubx is expressed in the enlarged segments of hind legs. Furthermore, we demonstrate that depletion of Ubx during embryogenesis has a primary effect in T3 legs and causes shortening of leg segments that are enlarged in a wild type. This result shows that Ubx is regulating the differential growth and enlargement of T3 legs in both Oncopeltus and Acheta. The emerging view suggests that Ubx was co-opted for a novel role in regulating leg growth and that the transcriptional modification of its expression may be a universal mechanism for the evolutionary diversification of insect hind legs.

  19. MR angiography of the pelvic and lower leg arteries: starting with time-resolved imaging of the lower leg is recommended

    International Nuclear Information System (INIS)

    Schmitt, R.; Christopoulos, G.; Brunner, S.; Froehner, S.; Dobritz, M.; Fellner, F.

    2001-01-01

    58 patients suffering from peripheral arterial vascular disease were examined using contrast-enhanced MR angiography with the intention of optimizing the visualization of lower leg arteries. Different from the customary acquisition order, were first the arteries of the lower legs depicted with three time-resolved phases. Afterwards, the iliacal and femoral vessels were imaged by applying the floating-table technique in two steps. In all cases, the lower leg arteries were depicted without overlying veins. By injecting the contrast agent in two phases, imaging quality of the iliofemoral arteries was not significantly reduced. - In conclusion, we would recommend the hybrid technique of peripheral contrast-enhanced MRA with primarily starting the acquisition of the lower legs in cases of foot infections or ulcerations where the transit time is reduced bi- or unilaterally. (orig.) [de

  20. Laterality of the legs in young female soccer players

    Directory of Open Access Journals (Sweden)

    Antosiak-Cyrak Katarzyna Z.

    2015-12-01

    Full Text Available Purpose. The aim of the present study was assessment of laterality of the legs of young female soccer players and their non-training counterparts. Methods. The study sample comprised 9 female soccer players and 19 non-training girls. They underwent three measurement sessions, one every six months. The applied tests included kinesthetic differentiation, rate of local movements, static balance, single-leg hop, rate of global movements, strength and speed, and functional asymmetry of the legs tests. Results. The soccer players were better than the controls in their performance of the rate of local movements, rate of global movements, kinesthetic differentiation, single-leg 15m timed hop and static balance tests. Smaller differences between the results of the left and the right legs in soccer players, than in non-training girls, were noted in the rate of local movements, rate of global movements and kinesthetic differentiation tests. In the static balance test, the differences were greater in the group of soccer players. Conclusions. Lateralization of the lower limbs is a highly complex characteristic with a different variability in athletes than in nontraining individuals. The results of the present study also point to the specialization of soccer players’ left legs in body balance and single-leg hop tests.

  1. Restless Legs Syndrome

    Science.gov (United States)

    ... disorder, particularly if they experience onset at an early age; many years may pass before symptoms occur regularly. top What causes restless legs syndrome? In most cases, the cause of RLS is unknown (called primary RLS). However, RLS has a genetic component and ...

  2. Nuclear power plant status diagnostics using artificial neural networks

    International Nuclear Information System (INIS)

    Bartlett, E.B.; Uhrig, R.E.

    1991-01-01

    In this work, the nuclear power plant operating status recognition issue is investigated using artificial neural networks (ANNs). The objective is to train an ANN to classify nuclear power plant accident conditions and to assess the potential of future work in the area of plant diagnostics with ANNS. To this end, an ANN was trained to recognize normal operating conditions as well as potentially unsafe conditions based on nuclear power plant training simulator generated accident scenarios. These scenarios include; hot and cold leg loss of coolant, control rod ejection, loss of offsite power, main steam line break, main feedwater line break and steam generator tube leak accidents. Findings show that ANNs can be used to diagnose and classify nuclear power plant conditions with good results

  3. Confining but chirally symmetric dense and cold matter

    International Nuclear Information System (INIS)

    Glozman, L. Ya.

    2012-01-01

    The possibility for existence of cold, dense chirally symmetric matter with confinement is reviewed. The answer to this question crucially depends on the mechanism of mass generation in QCD and interconnection of confinement and chiral symmetry breaking. This question can be clarified from spectroscopy of hadrons and their axial properties. Almost systematical parity doubling of highly excited hadrons suggests that their mass is not related to chiral symmetry breaking in the vacuum and is approximately chirally symmetric. Then there is a possibility for existence of confining but chirally symmetric matter. We clarify a possible mechanism underlying such a phase at low temperatures and large density. Namely, at large density the Pauli blocking prevents the gap equation to generate a solution with broken chiral symmetry. However, the chirally symmetric part of the quark Green function as well as all color non-singlet quantities are still infrared divergent, meaning that the system is with confinement. A possible phase transition to such a matter is most probably of the first order. This is because there are no chiral partners to the lowest lying hadrons.

  4. Thermo-mechanical design methodology for ITER cryo-distribution cold boxes

    International Nuclear Information System (INIS)

    Shukla, Vinit; Patel, Pratik; Vaghela, Hiten; Das, Jotirmoy; Shah, Nitin; Bhattacharya, Ritendra; Sarkar, Biswanath; Chang, Hyun-sik

    2015-01-01

    The ITER cryo-distribution system is in charge of the proper distribution of the cryogen at required mass flow rate, pressure and temperature level to the users namely; the superconducting magnets and cryopumps. The cryo-distribution also acts as a thermal buffer in order to run the cryo-plant as much as possible at a steady state condition. A typical cryo-distribution cold box is equipped with mainly liquid helium bath with heat exchangers, cryogenic valves, cold circulating pump and cold compressor. During the intended operation life of ITER, several loads on the cryo-distribution system are envisaged, these are, gravity/assembly loads, nominal pressure/temperature, test pressure/temperature, purge pressure, thermo-mechanical loads due to break of insulation vacuum, transport acceleration and seismic loads. Single loads or combinations of them can act on the cryo-distribution system and its components; therefore, it is very important to analyze the behavior of the system and components under the influence of these loads or combinations. Possible load combinations for the cryo-distribution system will be analyzed and will lead to the basis of the design. This paper will focus on the understanding of the nature of the loads and their combinations for the ITER cryo-distribution as well as their impacts on the design. A representative model of a cold box is considered on which the load combinations have been applied in order to understand their impacts on the design of the cryo-distribution. Also the worst-impact loads or their combination which drive the design of cryo-distribution cold boxes will be derived. (author)

  5. Extension and customization of self-stability control in compliant legged systems

    International Nuclear Information System (INIS)

    Ernst, M; Blickhan, R; Geyer, H

    2012-01-01

    Several recent studies on the control of legged locomotion in animal and robot running focus on the influence of different leg parameters on gait stability. In a preceding investigation self-stability controls showing deadbeat behavior could be obtained by studying the dynamics of the system in dependence of the leg orientation carefully adjusted during the flight phase. Such controls allow to accommodate disturbances of the ground level without having to detect them. Here we further this method in two ways. Besides the leg orientation, we allow changes in leg stiffness during flight and show that this extension substantially improves the rejection of ground disturbances. In a human like example the tolerance of random variation in ground level over many steps increased from 3.5% to 35% of leg length. In single steps changes of about 70% leg length (either up or down) could be negotiated. The variable leg stiffness not only allows to start with flat leg orientations maximizing step tolerances but also increase the control subspace. This allows to customize self-stability controls and to consider physical and technical limitations found in animals and robots. (paper)

  6. [Design and application of medical electric leg-raising machine].

    Science.gov (United States)

    Liang, Jintang; Chen, Jinyuan; Zhao, Zixian; Lin, Jinfeng; Li, Juanhong; Zhong, Jingliang

    2017-08-01

    Passive leg raising is widely used in clinic, but it lacks of specialized mechanical raise equipment. It requires medical staff to raise leg by hand or requires a multi-functional bed to raise leg, which takes time and effort. Therefore we have developed a new medical electric leg-raising machine. The equipment has the following characteristics: simple structure, stable performance, easy operation, fast and effective, safe and comfortable. The height range of the lifter is 50-120 cm, the range of the angle of raising leg is 10degree angle-80degree angle, the maximum supporting weight is 40 kg. Because of raising the height of the lower limbs and making precise angle, this equipment can completely replace the traditional manner of lifting leg by hand with multi-functional bed to lift patients' leg and can reduce the physical exhaustion and time consumption of medical staff. It can change the settings at any time to meet the needs of the patient; can be applied to the testing of PLR and dynamically assessing the hemodynamics; can prevent deep vein thrombosis and some related complications of staying in bed; and the machine is easy to be cleaned and disinfected, which can effectively avoid hospital acquired infection and cross infection; and can also be applied to emergency rescue of various disasters and emergencies.

  7. Leg-adjustment strategies for stable running in three dimensions

    International Nuclear Information System (INIS)

    Peuker, Frank; Maufroy, Christophe; Seyfarth, André

    2012-01-01

    The dynamics of the center of mass (CoM) in the sagittal plane in humans and animals during running is well described by the spring-loaded inverted pendulum (SLIP). With appropriate parameters, SLIP running patterns are stable, and these models can recover from perturbations without the need for corrective strategies, such as the application of additional forces. Rather, it is sufficient to adjust the leg to a fixed angle relative to the ground. In this work, we consider the extension of the SLIP to three dimensions (3D SLIP) and investigate feed-forward strategies for leg adjustment during the flight phase. As in the SLIP model, the leg is placed at a fixed angle. We extend the scope of possible reference axes from only fixed horizontal and vertical axes to include the CoM velocity vector as a movement-related reference, resulting in six leg-adjustment strategies. Only leg-adjustment strategies that include the CoM velocity vector produced stable running and large parameter domains of stability. The ability of the model to recover from perturbations along the direction of motion (directional stability) depended on the strategy for lateral leg adjustment. Specifically, asymptotic and neutral directional stability was observed for strategies based on the global reference axis and the velocity vector, respectively. Additional features of velocity-based leg adjustment are running at arbitrary low speed (kinetic energy) and the emergence of large domains of stable 3D running that are smoothly transferred to 2D SLIP stability and even to 1D SLIP hopping. One of the additional leg-adjustment strategies represented a large convex region of parameters where stable and robust hopping and running patterns exist. Therefore, this strategy is a promising candidate for implementation into engineering applications, such as robots, for instance. In a preliminary comparison, the model predictions were in good agreement with the experimental data, suggesting that the 3D SLIP is an

  8. Preoperative hypoalgesia after cold pressor test and aerobic exercise is associated with pain relief six months after total knee replacement

    DEFF Research Database (Denmark)

    Vaegter, Henrik Bjarke; Handberg, Gitte; Emmeluth, Claus

    2017-01-01

    OBJECTIVES: Chronic pain after total knee replacement (TKR) is not uncommon. Preoperative impaired conditioning pain modulation (CPM) has been used to predict chronic postoperative pain. Interestingly, exercises reduce pain sensitivity in patients with knee osteoarthritis. This pilot study...... investigated the association between exercise-induced hypoalgesia (EIH) and CPM on post-TKR pain relief. METHODS: Before and six months post-TKR, 14 patients with chronic knee osteoarthritis performed the cold pressor test on the non-affected leg and two exercise conditions (bicycling and isometric knee...... at the affected leg improved post-TKR compared with pre-TKR (PCPM and bicycling EIH assessed by the increase in cPTT correlated with reduction in NRS pain scores post-TKR (PCPM and EIH responses after TKR were significantly correlated with reduction in NRS pain scores...

  9. Lower Limb Symmetry: Comparison of Muscular Power Between Dominant and Nondominant Legs in Healthy Young Adults Associated With Single-Leg-Dominant Sports.

    Science.gov (United States)

    Vaisman, Alex; Guiloff, Rodrigo; Rojas, Juan; Delgado, Iris; Figueroa, David; Calvo, Rafael

    2017-12-01

    Achieving a symmetrical power performance (difference power between the dominant and nondominant legs in healthy young adults, (2) evaluate the effect of a single-leg-dominant sport activity performed at the professional level, and (3) propose a parameter of normality for maximal power difference in the lower limbs of this young adult population. Controlled laboratory study. A total of 78 healthy, male, young adults were divided into 2 groups according to sport activity level. Group 1 consisted of 51 nonathletes (mean ± SD age, 20.8 ± 1.5 years; weight, 71.9 ± 10.5 kg) who participated in less than 8 hours a week of recreational physical activity with nonspecific training; group 2 consisted of 27 single-leg-dominant professional soccer players (age, 18.4 ± 0.6 years; weight, 70.1 ± 7.5 kg) who specifically trained and competed at their particular activity 8 hours or more a week. For assessment of maximal leg power, both groups completed the single-leg squat jump test. Dominance was determined when participants completed 2 of 3 specific tests with the same extremity. Statistical analysis included the Student t test. No statistical difference was found for maximal power between dominant and nondominant legs for nonathletes ( t = -1.01, P = .316) or single-leg-dominant professional soccer players ( t = -1.10, P = .281). A majority (95%) of participants studied showed a power difference of less than 15% between their lower extremities. Among young healthy adults, symmetrical power performance is expected between lower extremities independent of the existence of dominance and difference in sport activity level. A less than 15% difference in power seems to be a proper parameter to define symmetrical power performance assessed by vertical single-leg jump tests.

  10. How cold is cold dark matter?

    International Nuclear Information System (INIS)

    Armendariz-Picon, Cristian; Neelakanta, Jayanth T.

    2014-01-01

    If cold dark matter consists of particles, these must be non-interacting and non-relativistic by definition. In most cold dark matter models however, dark matter particles inherit a non-vanishing velocity dispersion from interactions in the early universe, a velocity that redshifts with cosmic expansion but certainly remains non-zero. In this article, we place model-independent constraints on the dark matter temperature to mass ratio, whose square root determines the dark matter velocity dispersion. We only assume that dark matter particles decoupled kinetically while non-relativistic, when galactic scales had not entered the horizon yet, and that their momentum distribution has been Maxwellian since that time. Under these assumptions, using cosmic microwave background and matter power spectrum observations, we place upper limits on the temperature to mass ratio of cold dark matter today (away from collapsed structures). These limits imply that the present cold dark matter velocity dispersion has to be smaller than 54 m/s. Cold dark matter has to be quite cold, indeed

  11. Flexural characteristics of a stack leg

    International Nuclear Information System (INIS)

    Cook, J.

    1979-06-01

    A 30 MV tandem Van de Graaff accelerator is at present under construction at Daresbury Laboratory. The insulating stack of the machine is of modular construction, each module being 860 mm in length. Each live section stack module contains 8 insulating legs mounted between bulkhead rings. The design, fabrication (from glass discs bonded to stainless steel discs using an epoxy film adhesive) and testing of the stack legs is described. (U.K.)

  12. Cold Antimatter Plasmas, and Aspirations for Cold Antihydrogen

    Science.gov (United States)

    2002-06-24

    UNCLASSIFIED Defense Technical Information Center Compilation Part Notice ADP012494 TITLE: Cold Antimatter Plasmas, and Aspirations for Cold...part numbers comprise the compilation report: ADP012489 thru ADP012577 UNCLASSIFIED Cold Antimatter Plasmas, and Aspirations for Cold Antihydrogen G...and positrons. The antiprotons come initially from the new Antiproton Decel- erator facility at CERN. Good control of such cold antimatter plasmas is

  13. Leg deformation during imaginal ecdysis in the downy emerald, Cordulia aenea (Odonata, Corduliidae).

    Science.gov (United States)

    Frantsevich, Leonid; Frantsevich, Ludmilla

    2018-04-01

    A dragonfly larva migrates from the water to the shore, perches on a plant stem and grasps it with strongly flexed legs. Adult legs inside the larval exoskeleton fit to the larval legs joint-to-joint. The adult emerges with stretched legs. During the molt, an imaginal leg must follow all the angles in exuvial joints. In turn, larval apodemes are withdrawn from imaginal legs. We visualized transient shapes of the imaginal legs by the instant fixation of insects at different moments of the molt, photographed isolated exuvial legs with the imaginal legs inside and then removed the exuvial sheath. Instant shapes of the imaginal tibia show sharp intrapodomere bends copying the angle in the larval femoro-tibial joint. The site of bending shifts distad during the molt. This is possible if the imaginal leg is pliable. The same problem of leg squeezing is also common in hemimetabolous insects as well as in other arthropods, whereas holometabolous insects overcome problems of a tight confinement either by using leg pliability in other ways but not squeezing (cyclorrhaphan flies, mosquitoes) or by pulling hardened legs out without change of their pupal zigzag configuration (moths, ants, honey bees). The pupal legs are not intended to grasp any external substrate. Copyright © 2018 Elsevier GmbH. All rights reserved.

  14. Dynamical instability induced by the zero mode under symmetry breaking external perturbation

    International Nuclear Information System (INIS)

    Takahashi, J.; Nakamura, Y.; Yamanaka, Y.

    2014-01-01

    A complex eigenvalue in the Bogoliubov–de Gennes equations for a stationary Bose-Einstein condensate in the ultracold atomic system indicates the dynamical instability of the system. We also have the modes with zero eigenvalues for the condensate, called the zero modes, which originate from the spontaneous breakdown of symmetries. Although the zero modes are suppressed in many theoretical analyses, we take account of them in this paper and argue that a zero mode can change into one with a pure imaginary eigenvalue by applying a symmetry breaking external perturbation potential. This emergence of a pure imaginary mode adds a new type of scenario of dynamical instability to that characterized by the complex eigenvalue of the usual excitation modes. For illustration, we deal with two one-dimensional homogeneous Bose–Einstein condensate systems with a single dark soliton under a respective perturbation potential, breaking the invariance under translation, to derive pure imaginary modes. - Highlights: • Zero modes are important but ignored in many theories for the cold atomic system. • We discuss the zero mode under symmetry breaking potential in this system. • We consider the zero mode of translational invariance for a single dark soliton. • We show that it turns into an anomalous or pure imaginary mode

  15. The physiological role of fat body and muscle tissues in response to cold stress in the tropical cockroach Gromphadorhina coquereliana.

    Directory of Open Access Journals (Sweden)

    Szymon Chowański

    Full Text Available Protective mechanisms against cold stress are well studied in terrestrial and polar insects; however, little is known about these mechanisms in tropical insects. In our study, we tested if a tropical cockroach Gromphadorhina coquereliana, possesses any protective mechanisms against cold stress. Based on the results of earlier studies, we examined how short-term (3 h cold (4°C influences biochemical parameters, mitochondrial respiration activity, and the level of HSPs and aquaporins expression in the fat body and leg muscles of G. coquereliana. Following cold exposure, we found that the level of carbohydrates, lipids and proteins did not change significantly. Nevertheless, we observed significant changes in mitochondrial respiration activity. The oxygen consumption of resting (state 4 and phosphorylating (state 3 mitochondria was altered following cold exposure. The increase in respiratory rate in state 4 respiration was observed in both tissues. In state 3, oxygen consumption by mitochondria in fat body was significantly lower compared to control insects, whereas there were no changes observed for mitochondria in muscle tissue. Moreover, there were cold-induced changes in UCP protein activity, but the changes in activity differed in fat body and in muscles. Additionally, we detected changes in the level of HSP70 and aquaporins expression. Insects treated with cold had significantly higher levels of HSP70 in fat body and muscles. On the other hand, there were lower levels of aquaporins in both tissues following exposure to cold. These results suggest that fat body play an important role in protecting tropical insects from cold stress.

  16. Running over unknown rough terrain with a one-legged planar robot

    International Nuclear Information System (INIS)

    Andrews, Ben; Miller, Bruce; Clark, Jonathan E; Schmitt, John

    2011-01-01

    The ability to traverse unknown, rough terrain is an advantage that legged locomoters have over their wheeled counterparts. However, due to the complexity of multi-legged systems, research in legged robotics has not yet been able to reproduce the agility found in the animal kingdom. In an effort to reduce the complexity of the problem, researchers have developed single-legged models to gain insight into the fundamental dynamics of legged running. Inspired by studies of animal locomotion, researchers have proposed numerous control strategies to achieve stable, one-legged running over unknown, rough terrain. One such control strategy incorporates energy variations into the system during the stance phase by changing the force-free leg length as a sinusoidal function of time. In this research, a one-legged planar robot capable of implementing this and other state-of-the-art control strategies was designed and built. Both simulated and experimental results were used to determine and compare the stability of the proposed controllers as the robot was subjected to unknown drop and raised step perturbations equal to 25% of the nominal leg length. This study illustrates the relative advantages of utilizing a minimal-sensing, active energy removal control scheme to stabilize running over rough terrain.

  17. Spider diffraction: a comparison of curved and straight legs

    International Nuclear Information System (INIS)

    Richter, J.L.

    1984-01-01

    It has been known for some time that, if curved legs rather than the usual straight ones are used in the spider that supports the secondary optics in certain telescopes, the visible diffraction effect is reduced. Fraunhofer theory is used to calculate the diffraction effects due to the curved leg spider. Calculated and photographic diffraction patterns are compared for straight and curved leg spiders

  18. Straight leg elevation to rule out pelvic injury.

    Science.gov (United States)

    Bolt, Caroline; O'Keeffe, Francis; Finnegan, Pete; Dickson, Kristofer; Smit, De Villiers; Fitzgerald, Mark C; Mitra, Biswadev

    2018-02-01

    Pelvic x-ray is frequently used as a screening tool during initial assessment of injured patients. However routine use in the awake and alert blunt trauma patient may be questioned due to low yield. We propose a clinical tool that may avoid unnecessary imaging by examining whether the ability to straight leg raise, without pain, can rule out pelvic injury. We conducted a prospective cohort study with the exposure variables of ability to straight leg raise and presence of pain on doing so, and presence of pelvic fracture on x-ray as the primary outcome variable. Of the 328 participants, 35 had pelvic fractures, and of these 32 were either unable to straight leg raise, or had pain on doing so, with a sensitivity of 91.43% (95% CI: 76.94-98.2%) and a negative predictive value of 98.57% (95% CI: 95.88-99.70%). The 3 participants with a pelvic fracture who could straight leg raise with no pain, all had a GCS of less than 15, and therefore, among the sub-group of patients with GCS15, a 100% sensitivity and 100% negative predictive value for straight leg raise with no pain to rule out pelvic fracture was demonstrated. Among awake, alert patients, painless straight leg raise can exclude pelvic fractures and be incorporated into initial examination during reception and resuscitation of injured patients. Crown Copyright © 2017. Published by Elsevier Ltd. All rights reserved.

  19. Evaluation of Thermoelectric Performance and Durability of Functionalized Skutterudite Legs

    Science.gov (United States)

    Skomedal, Gunstein; Kristiansen, Nils R.; Sottong, Reinhard; Middleton, Hugh

    2017-04-01

    Thermoelectric generators are a promising technology for waste heat recovery. As new materials and devices enter a market penetration stage, it is of interest to employ fast and efficient measurement methods to evaluate the long-term stability of thermoelectric materials in combination with metallization and coating (functionalized thermoelectric legs). We have investigated a method for measuring several thermoelectric legs simultaneously. The legs are put under a common temperature gradient, and the electrical characteristics of each leg are measured individually during thermal cycling. Using this method, one can test different types of metallization and coating applied to skutterudite thermoelectric legs and look at the relative changes over time. Postcharacterization of these initial tests with skutterudite legs using a potential Seebeck microprobe and an electron microscope showed that oxidation and interlayer diffusion are the main reasons for the gradual increase in internal resistance and the decrease in open-circuit voltage. Although we only tested skutterudite material in this work, the method is fully capable of testing all kinds of material, metallization, and coating. It is thus a promising method for studying the relationship between failure modes and mechanisms of functionalized thermoelectric legs.

  20. The effects of growth rate on leg morphology and tibia breaking strength, mineral density, mineral content, and bone ash in broilers.

    Science.gov (United States)

    Shim, M Y; Karnuah, A B; Mitchell, A D; Anthony, N B; Pesti, G M; Aggrey, S E

    2012-08-01

    Fast-growing broilers are especially susceptible to bone abnormalities, causing major problems for broiler producers. The cortical bones of fast-growing broilers are highly porous, which may lead to leg deformities. Leg problems were investigated in 6-wk-old Arkansas randombred broilers. Body weight was measured at hatch and at 6 wk. There were 8 different settings of approximately 450 eggs each. Two subpopulations, slow-growing (SG; bottom quarter, n=511) and fast-growing (FG; top quarter, n=545), were created from a randombred population based on their growth rate from hatch until 6 wk of age. At 6 wk of age, the broilers were processed and chilled at 4°C overnight before deboning. Shank (78.27±8.06 g), drum stick (190.92±16.91 g), and thigh weights (233.88±22.66 g) of FG broilers were higher than those of SG broilers (54.39±6.86, 135.39±15.45, and 168.50±21.13 g, respectivly; Ppercentage of ash content (39.76±2.81) of FG broilers was lower than that of SG broilers (39.99±2.67; P=0.173). Fast-growing broiler bones were longer, wider, heavier, stronger, more dense, and contained more ash than SG ones. After all parameters were calculated per unit of final BW at 6 wk, tibia density and bone ash percentage of FG broilers were lower than those of SG broilers.

  1. Relationship between Leg Mass, Leg Composition and Foot Velocity on Kicking Accuracy in Australian Football

    Directory of Open Access Journals (Sweden)

    Nicolas H. Hart, Jodie L. Cochrane, Tania Spiteri, Sophia Nimphius, Robert U. Newton

    2016-06-01

    Full Text Available Kicking a ball accurately over a desired distance to an intended target is arguably the most important skill to acquire in Australian Football. Therefore, understanding the potential mechanisms which underpin kicking accuracy is warranted. The aim of this study was to examine the relationship between leg mass, leg composition and foot velocity on kicking accuracy in Australian Football. Thirty-one Australian Footballers (n = 31; age: 22.1 ± 2.8 years; height: 1.81 ± 0.07 m; weight: 85.1 ± 13.0 kg; BMI: 25.9 ± 3.2 each performed ten drop punt kicks over twenty metres to a player target. Athletes were separated into accurate (n = 15 and inaccurate (n = 16 kicking groups. Leg mass characteristics were assessed using whole body DXA scans. Foot velocity was determined using a ten-camera optoelectronic, three-dimensional motion capture system. Interactions between leg mass and foot velocity evident within accurate kickers only (r = -0.670 to -0.701. Relative lean mass was positively correlated with kicking accuracy (r = 0.631, while no relationship between foot velocity and kicking accuracy was evident in isolation (r = -0.047 to -0.083. Given the evident importance of lean mass, and its interaction with foot velocity for accurate kickers; future research should explore speed-accuracy, impulse-variability, limb co-ordination and foot-ball interaction constructs in kicking using controlled with-in subject studies to examine the effects of resistance training and skill acquisition programs on the development of kicking accuracy.

  2. Improving long term driving comfort by taking breaks - how break activity affects effectiveness

    OpenAIRE

    Sammonds, GM; Mansfield, NJ; Fray, M

    2017-01-01

    During long duration journeys, drivers are encouraged to take regular breaks. The benefits of breaks have been documented for safety; breaks may also be beneficial for comfort. The activity undertaken during a break may influence its effectiveness. Volunteers completed 3 journeys on a driving simulator. Each 130 min journey included a 10 min break after the first hour. During the break volunteers either stayed seated, left the simulator and sat in an adjacent room, or took a walk on a treadmi...

  3. Hypothermic general cold adaptation induced by local cold acclimation.

    Science.gov (United States)

    Savourey, G; Barnavol, B; Caravel, J P; Feuerstein, C; Bittel, J H

    1996-01-01

    To study relationships between local cold adaptation of the lower limbs and general cold adaptation, eight subjects were submitted both to a cold foot test (CFT, 5 degrees C water immersion, 5 min) and to a whole-body standard cold air test (SCAT, 1 degree C, 2 h, nude at rest) before and after a local cold acclimation (LCA) of the lower limbs effected by repeated cold water immersions. The LCA induced a local cold adaptation confirmed by higher skin temperatures of the lower limbs during CFT and a hypothermic insulative general cold adaptation (decreased rectal temperature and mean skin temperature P adaptation was related to the habituation process confirmed by decreased plasma concentrations of noradrenaline (NA) during LCA (P general cold adaptation was unrelated either to local cold adaptation or to the habituation process, because an increased NA during SCAT after LCA (P syndrome" occurring during LCA.

  4. Improving long term driving comfort by taking breaks - How break activity affects effectiveness.

    Science.gov (United States)

    Sammonds, George M; Mansfield, Neil J; Fray, Mike

    2017-11-01

    During long duration journeys, drivers are encouraged to take regular breaks. The benefits of breaks have been documented for safety; breaks may also be beneficial for comfort. The activity undertaken during a break may influence its effectiveness. Volunteers completed 3 journeys on a driving simulator. Each 130 min journey included a 10 min break after the first hour. During the break volunteers either stayed seated, left the simulator and sat in an adjacent room, or took a walk on a treadmill. The results show a reduction in driver discomfort during the break for all 3 conditions, but the effectiveness of the break was dependent on activity undertaken. Remaining seated in the vehicle provided some improvement in comfort, but more was experienced after leaving the simulator and sitting in an adjacent room. The most effective break occurred when the driver walked for 10 min on a treadmill. The benefits from taking a break continued until the end of the study (after a further hour of driving), such that comfort remained the best after taking a walk and worst for those who remained seated. It is concluded that taking a break and taking a walk is an effective method for relieving driving discomfort. Copyright © 2017 Elsevier Ltd. All rights reserved.

  5. A survey of bio-inspired compliant legged robot designs

    International Nuclear Information System (INIS)

    Zhou Xiaodong; Bi Shusheng

    2012-01-01

    The roles of biological springs in vertebrate animals and their implementations in compliant legged robots offer significant advantages over the rigid legged ones in certain types of scenarios. A large number of robotics institutes have been attempting to work in conjunction with biologists and incorporated these principles into the design of biologically inspired robots. The motivation of this review is to investigate the most published compliant legged robots and categorize them according to the types of compliant elements adopted in their mechanical structures. Based on the typical robots investigated, the trade-off between each category is summarized. In addition, the most significant performances of these robots are compared quantitatively, and multiple available solutions for the future compliant legged robot design are suggested. Finally, the design challenges for compliant legged robots are analysed. This review will provide useful guidance for robotic designers in creating new designs by inheriting the virtues of those successful robots according to the specific tasks. (topical review)

  6. Hydraulic Response of Caisson Breakwaters in Multidirectional Breaking and Non-Breaking Waves

    DEFF Research Database (Denmark)

    Grønbech, J.; Kofoed, Jens Peter; Hald, Tue

    1998-01-01

    The present paper concerns the results and findings of a physical study on wave impacts on vertical caisson breakwaters situated in irregular, multidirectional breaking seas. The study has taken place as part of the framework programme "Dynamic of Structures" financially supported by the Danish T...... breaking waves at deep water. The study on wave overtopping showed that the 3D wave overtopping formula suggested by Franco et al., 1995b, predicts the wave overtopping reasonable well for both non breaking and breaking waves at deep water.......The present paper concerns the results and findings of a physical study on wave impacts on vertical caisson breakwaters situated in irregular, multidirectional breaking seas. The study has taken place as part of the framework programme "Dynamic of Structures" financially supported by the Danish...... induced loading and overtopping on caisson breakwaters situated in breaking seas. Regarding the wave forces only minor differences between breaking and non breaking waves in deep water were observed, and it was found that the prediction formula of Goda also seems to apply well for multidirectionally...

  7. SB LOCA analyses for Krsko Full Scope Simulator verification

    International Nuclear Information System (INIS)

    Prosek, A.; Parzer, I.; Mavko, B.

    2000-01-01

    Nuclear power plant simulators are intended to be used for training and maintaining competence to ensure safe, reliable operation of nuclear power plants throughout the world. The simulator shall be specified to a reference unit and its performance validation testing shall be provided. In this study a small-break loss-of-coolant accident (SB LOCA) response of Krsko nuclear power plant (NPP) was calculated for full scope simulator verification. The investigation included five cases with varying the break size in the cold leg of reactor coolant system. The plant specific and verified RELAP5/MOD2 model of Krsko nuclear power plant (NPP), developed in the past for 1882 MWt power, was adapted for 2000 MWt power (cycle 17) including the model for replacement steam generators. The results showed that the plant system response to breaks with small break area was slower compared to breaks with larger break area. The core heatup occurred in most of the cases analyzed. The acceptance criteria for emergency core cooling system were also met. The predicted results of the SB LOCA analysis for Krsko NPP suggest that they may be used for verification of the Krsko Full Scope Simulator performance. (author)

  8. Exocrine glands in the legs of the social wasp Vespula vulgaris.

    Science.gov (United States)

    Nijs, Catherine; Billen, Johan

    2015-09-01

    This study brings a survey of the exocrine glands in the legs of Vespula vulgaris wasps. We studied workers, males, virgin queens as well as mated queens. A variety of 17 glands is found in the different leg segments. Among these, five glands are novel exocrine structures for social insects (trochanter-femur gland, ventrodistal tibial gland, distal tibial sac gland, ventral tibial gland, and ventral tarsomere gland). Most leg glands are present in the three leg pairs of all castes. This may indicate a mechanical function. This is likely for the numerous glands that occur near the articulation between the various leg segments, where lubricant production may be expected. Other possible functions include antenna cleaning, acting as a hydraulic system, or pheromonal. Further research including leg-related behavioural observations and chemical analyses may help to clarify the functions of these glandular structures in the legs. Copyright © 2015 Elsevier Ltd. All rights reserved.

  9. Characteristics of steam jet impingement on annulus

    International Nuclear Information System (INIS)

    Yoon, Sang H.; Kim, Won J.; Suh, Kune Y.; Song, Chul H.

    2004-01-01

    The steam jet impingement occurs when the steam through the cold leg from the steam generator strikes the inner reactor barrel during the reflood phase of a loss-of-coolant accident (LOCA), which is a characteristic behavior for the APR1400 (Advanced Power Reactor 1400 MWe). In the cold leg break LOCA, the steam and water flows in the downcomer are truly multidimensional. The azimuthal velocity distribution of the steam flow has an important bearing on the thermal hydraulic phenomena such as the emergency coolant water direct bypass, sweepout, steam condensation, and so forth. The investigation of jet flow is required to determine the steam path and momentum reduction rate after the impingement. For the observation of the steam behavior near the break, the computational fluid dynamic (CFD) analysis has been carried out using CFX5.6. The flow visualization and analysis demonstrate the velocity profiles of the steam flow in the annulus region for the same boundary conditions. Pursuant to the CFD results, the micro-Pitot tubes were positioned at varying angles, and corrected for their sensitivity. The experiments were carried out to directly measure the pressure differential and to visualize the flow utilizing a smoke injection method. Results from this study are slated to be applied to MARS, which is a thermal hydraulic system code for the best-estimate analysis. The current one- or two-dimensional analysis in MARS was known to distort the local flow behavior. To enhance prediction capability of MARS, it is necessary to inspect the steam path in the break flow and mechanically simulate the momentum variation. The present experimental and analytical results can locally be applied to developing the engineering models of specific and essential phenomena. (author)

  10. Development and Physical Control Research on Prototype Artificial Leg

    Directory of Open Access Journals (Sweden)

    Fei Li

    2016-03-01

    Full Text Available To provide an ideal platform for research on intelligent bionic leg (IBL, this paper proposes a model of a biped robot with heterogeneous legs (BRHL. A prototype of an artificial leg is developed based on biological structure and motion principle analysis of human lower extremities. With regard to the driving sources, servomotors are chosen for the hip joint and ankle joint, while pneumatic muscle actuators (PMAs are chosen for the knee joint. The control system of the bionic artificial leg is designed and a physical experimental platform is established. The physical control experiments are done based on proportional-integral-derivative (PID control strategy. The experimental results show that such a system can realize the expected goals.

  11. Seismic response analysis for hinged-leg type port crane

    Energy Technology Data Exchange (ETDEWEB)

    Kashiwazaki, A.; Kanayama, T.; Arai, K. [Ishikawajima-Harima Heavy Industries Co. Ltd., Tokyo (Japan)

    2000-04-01

    Container cranes and unloaders in Kobe Pont were severely damaged during the Southern Hyogo Prefecture Earthquake in 1995. Notably, some of the hinged-leg type of cranes with hinges at the end of sea-or land-side of legs were overturned. These damages were derived from the uplifting of their legs. To explain the uplifting and overturning behavior, we carried out nonlinear analyses and shaking table tests using a 1/8-scale model of the container crane. The results of nonlinear response analyses of hinged-leg type of crane, which are in an agreement with the state of damages in the Southern Hyogo Prefecture Earthquake and the result of shaking table tests, are described. (author)

  12. Anatomic and functional leg-length inequality: A review and recommendation for clinical decision-making. Part I, anatomic leg-length inequality: prevalence, magnitude, effects and clinical significance

    Directory of Open Access Journals (Sweden)

    Knutson Gary A

    2005-07-01

    Full Text Available Abstract Background Leg-length inequality is most often divided into two groups: anatomic and functional. Part I of this review analyses data collected on anatomic leg-length inequality relative to prevalence, magnitude, effects and clinical significance. Part II examines the functional "short leg" including anatomic-functional relationships, and provides an outline for clinical decision-making. Methods Online database – Medline, CINAHL and MANTIS – and library searches for the time frame of 1970–2005 were done using the term "leg-length inequality". Results and Discussion Using data on leg-length inequality obtained by accurate and reliable x-ray methods, the prevalence of anatomic inequality was found to be 90%, the mean magnitude of anatomic inequality was 5.2 mm (SD 4.1. The evidence suggests that, for most people, anatomic leg-length inequality does not appear to be clinically significant until the magnitude reaches ~ 20 mm (~3/4". Conclusion Anatomic leg-length inequality is near universal, but the average magnitude is small and not likely to be clinically significant.

  13. 'BREAKS' Protocol for Breaking Bad News.

    Science.gov (United States)

    Narayanan, Vijayakumar; Bista, Bibek; Koshy, Cheriyan

    2010-05-01

    Information that drastically alters the life world of the patient is termed as bad news. Conveying bad news is a skilled communication, and not at all easy. The amount of truth to be disclosed is subjective. A properly structured and well-orchestrated communication has a positive therapeutic effect. This is a process of negotiation between patient and physician, but physicians often find it difficult due to many reasons. They feel incompetent and are afraid of unleashing a negative reaction from the patient or their relatives. The physician is reminded of his or her own vulnerability to terminal illness, and find themselves powerless over emotional distress. Lack of sufficient training in breaking bad news is a handicap to most physicians and health care workers. Adherence to the principles of client-centered counseling is helpful in attaining this skill. Fundamental insight of the patient is exploited and the bad news is delivered in a structured manner, because the patient is the one who knows what is hurting him most and he is the one who knows how to move forward. Six-step SPIKES protocol is widely used for breaking bad news. In this paper, we put forward another six-step protocol, the BREAKS protocol as a systematic and easy communication strategy for breaking bad news. Development of competence in dealing with difficult situations has positive therapeutic outcome and is a professionally satisfying one.

  14. Precooling leg muscle improves intermittent sprint exercise performance in hot, humid conditions.

    Science.gov (United States)

    Castle, Paul C; Macdonald, Adam L; Philp, Andrew; Webborn, Anthony; Watt, Peter W; Maxwell, Neil S

    2006-04-01

    We used three techniques of precooling to test the hypothesis that heat strain would be alleviated, muscle temperature (Tmu) would be reduced, and as a result there would be delayed decrements in peak power output (PPO) during exercise in hot, humid conditions. Twelve male team-sport players completed four cycling intermittent sprint protocols (CISP). Each CISP consisted of twenty 2-min periods, each including 10 s of passive rest, 5 s of maximal sprint against a resistance of 7.5% body mass, and 105 s of active recovery. The CISP, preceded by 20 min of no cooling (Control), precooling via an ice vest (Vest), cold water immersion (Water), and ice packs covering the upper legs (Packs), was performed in hot, humid conditions (mean +/- SE; 33.7 +/- 0.3 degrees C, 51.6 +/- 2.2% relative humidity) in a randomized order. The rate of heat strain increase during the CISP was faster in Control than Water and Packs (P body or whole body cooling.

  15. Modeling posture-dependent leg actuation in sagittal plane locomotion

    International Nuclear Information System (INIS)

    Schmitt, J; Clark, J

    2009-01-01

    The spring loaded inverted pendulum template has been shown to accurately model the steady locomotion dynamics of a variety of running animals, and has served as the inspiration for an entire class of dynamic running robots. While the template models the leg dynamics by an energy-conserving spring, insects and animals have structures that dissipate, store and produce energy during a stance phase. Recent investigations into the spring-like properties of limbs, as well as animal response to drop-step perturbations, suggest that animals use their legs to manage energy storage and dissipation, and that this management is important for gait stability. In this paper, we extend our previous analysis of control of the spring loaded inverted pendulum template via changes in the leg touch-down angle to include energy variations during the stance phase. Energy variations are incorporated through leg actuation that varies the force-free leg length during the stance phase, yet maintains qualitatively correct force and velocity profiles. In contrast to the partially asymptotically stable gaits identified in previous analyses, incorporating energy and leg angle variations in this manner produces complete asymptotic stability. Drop-step perturbation simulations reveal that the control strategy is rather robust, with gaits recovering from drops of up to 30% of the nominal hip height.

  16. A Dung Beetle-like Leg and its Adaptive Neural Control

    DEFF Research Database (Denmark)

    Di Canio, Giuliano; Stoyanov, Stoyan; Larsen, Jørgen Christian

    2016-01-01

    Dung beetles show fascinating locomotion abilities. They can use their legs to not only walk but also manipulate objects. Furthermore, they can perform their leg movements at a proper frequency with respect to their biomechanical properties and quickly adapt the movements to deal with external pe...... also apply adaptive neural control, based on a central pattern generator (CPG) circuit with synaptic plasticity, to autonomously generate a proper stepping frequency of the leg. The controller can also adapt the leg movement to deal with external perturbations within a few steps....

  17. Evaluation of post-LOCA long term cooling performance in Korean standard nuclear power plants

    International Nuclear Information System (INIS)

    Bang, Young Seok; Jung, Jae Won; Seul, Kwang Won; Kim, Hho Jung

    2001-01-01

    The post-LOCA long term cooling (LTC) performance of the Korean Standard Nuclear Power Plant (KSNPP) is analyzed for both small break loss-of-coolant accidents (LOCA) and large break LOCA at cold leg. The RELAP5/MOD3.2.2 beta code is used to calculate the LTC sequences based on the LTC plan of the Korean Standard Nuclear Power Plants (KSNPP). A standard input model is developed such that LOCA and the followed LTC sequence can be calculated in a single run for both small break LOCA and large break LOCA. A spectrum of small break LOCA ranging from 0.02 to 0.5 ft 2 of break area and a double-ended guillotine break are analyzed. Through the code calculations, the thermal-hydraulic behavior and the boron behavior are evaluated and the effect of the important action including the safety injection tank (SIT) isolation and the simultaneous injection in LTC procedure is investigated. As a result, it is found that the sufficient margin is available in avoiding the boron precipitation in the core. It is also found that a further specific condition for the SIT isolation action need to be setup and it is recommended that the early initiation of the simultaneous injection be taken for larger break LTC sequences. (author)

  18. Cold Stress

    Science.gov (United States)

    ... Publications and Products Programs Contact NIOSH NIOSH COLD STRESS Recommend on Facebook Tweet Share Compartir Workers who ... cold environments may be at risk of cold stress. Extreme cold weather is a dangerous situation that ...

  19. Conjoined legs: Sirenomelia or caudal regression syndrome?

    Directory of Open Access Journals (Sweden)

    Sakti Prasad Das

    2013-01-01

    Full Text Available Presence of single umbilical persistent vitelline artery distinguishes sirenomelia from caudal regression syndrome. We report a case of a12-year-old boy who had bilateral umbilical arteries presented with fusion of both legs in the lower one third of leg. Both feet were rudimentary. The right foot had a valgus rocker-bottom deformity. All toes were present but rudimentary. The left foot showed absence of all toes. Physical examination showed left tibia vara. The chest evaluation in sitting revealed pigeon chest and elevated right shoulder. Posterior examination of the trunk showed thoracic scoliosis with convexity to right. The patient was operated and at 1 year followup the boy had two separate legs with a good aesthetic and functional results.

  20. Conjoined legs: Sirenomelia or caudal regression syndrome?

    Science.gov (United States)

    Das, Sakti Prasad; Ojha, Niranjan; Ganesh, G Shankar; Mohanty, Ram Narayan

    2013-07-01

    Presence of single umbilical persistent vitelline artery distinguishes sirenomelia from caudal regression syndrome. We report a case of a12-year-old boy who had bilateral umbilical arteries presented with fusion of both legs in the lower one third of leg. Both feet were rudimentary. The right foot had a valgus rocker-bottom deformity. All toes were present but rudimentary. The left foot showed absence of all toes. Physical examination showed left tibia vara. The chest evaluation in sitting revealed pigeon chest and elevated right shoulder. Posterior examination of the trunk showed thoracic scoliosis with convexity to right. The patient was operated and at 1 year followup the boy had two separate legs with a good aesthetic and functional results.

  1. B-L mediated SUSY breaking with radiative B-L symmetry breaking

    International Nuclear Information System (INIS)

    Kikuchi, Tatsuru; Kubo, Takayuki

    2008-01-01

    We explore a mechanism of radiative B-L symmetry breaking in analogous to the radiative electroweak symmetry breaking. The breaking scale of B-L symmetry is related to the neutrino masses through the see-saw mechanism. Once we incorporate the U(1) B-L gauge symmetry in SUSY models, the U(1) B-L gaugino, Z-tilde B-L appears, and it can mediate the SUSY breaking (Z-prime mediated SUSY breaking) at around the scale of 10 6 GeV. Then we find a links between the neutrino mass (more precisly the see-saw or B-L scale of order 10 6 GeV) and the Z-prime mediated SUSY breaking scale. It is also very interesting that the gluino at the weak scale becomes relatively light, and almost compressed mass spectra for the gaugino sector can be realized in this scenario, which is very interesting in scope of the LHC.

  2. Molecular analysis of the distribution of chromosomal breakpoints: characterization of a 'hot' region for breaks in human chromosome 11

    International Nuclear Information System (INIS)

    Vannais, D.B.; Hirai, Y.; Cologne, J.B.; Waldren, C.A.; Ueno, A.

    2003-01-01

    Full text: Ionizing radiation randomly damages DNA and chromosomes whereas subsequent chromosome breaks are non-random. Assuming, as an ideal and naive but useful proposition, that breaks are equally likely anywhere in the chromosome and that a deletion always occurs between two breaks, the frequency of fragments would decrease linearly with increasing fragment size. This simple distribution is not, however, observed. To shed light on the 'real' situation of break formation we mapped breakpoints in the human chromosome no. 11 of 353 independent CD59- mutants isolated from human/hamster hybrid AL cells exposed to radiations (high and low dose-rate gamma rays, high LET carbon or nitrogen ions, protons) or chemicals (arsenic or irradiated, mutagenic histidine) or unexposed. The number of breaks per unit length of DNA differed significantly in different regions of chromosome 11.The highest level of breaks (140/mbp) were in the 0.8 mbp segment between CD59 and Catalase (CAT). Finer mapping of break points was carried out using 26 PCR primer pairs spread across this interval in 15 independent mutants. In two mutants, the break point was in a 107 bp fragment; in the other 13 the breaks were in a single 35 mbp fragment, but not all were at exactly the same site; 4 of 13 occurred in 3 different 3 mbp sub-segments. We are sequencing these fragments to look for such features as repeats: 'colder' regions like that between CD59 and WT will also be analyzed. But, since at least some breaks occurred at different sites and the frequency and distribution of breaks was about the same for all treatments, our we postulate that hot (and cold spots) may be due more to structural features or specific repair than to sequence or type of damage

  3. Simulation experiments for hot-leg U-bend two-phase flow phenomena

    International Nuclear Information System (INIS)

    Ishii, M.; Hsu, J.T.; Tucholke, D.; Lambert, G.; Kataoka, I.

    1986-01-01

    In order to study the two-phase natural circulation and flow termination during a small break loss of coolant accident in LWR, simulation experiments have been performed. Based on the two-phase flow scaling criteria developed under this program, an adiabatic hot leg U-bend simulation loop using nitrogen gas and water and a Freon 113 boiling and condensation loop were built. The nitrogen-water system has been used to isolate key hydrodynamic phenomena from heat transfer problems, whereas the Freon loop has been used to study the effect of phase changes and fluid properties. Various tests were carried out to establish the basic mechanism of the flow termination and reestablishment as well as to obtain essential information on scale effects of parameters such as the loop frictional resistance, thermal center, U-bend curvature and inlet geometry. In addition to the above experimental study, a preliminary modeling study has been carried out for two-phase flow in a large vertical pipe at relatively low gas fluxes typical of natural circulation conditions

  4. Treatment of vasovagal syncope: pacemaker or crossing legs?

    NARCIS (Netherlands)

    van Dijk, N.; Harms, M. P.; Linzer, M.; Wieling, W.

    2000-01-01

    A 50-year-old male patient continued to experience syncope after implantation of a pacemaker. During cardiovascular examination, the patient showed a typical vasovagal response, with normal pacemaker function. Leg crossing, which prohibits the pooling of blood in the legs and abdomen, at the onset

  5. 33 CFR 147.809 - Mars Tension Leg Platform safety zone.

    Science.gov (United States)

    2010-07-01

    ... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false Mars Tension Leg Platform safety... SECURITY (CONTINUED) OUTER CONTINENTAL SHELF ACTIVITIES SAFETY ZONES § 147.809 Mars Tension Leg Platform safety zone. (a) Description. The Mars Tension Leg Platform (Mars TLP) is located at position 28°10′10.29...

  6. Parental Break-Ups and Stress

    DEFF Research Database (Denmark)

    Dissing, Agnete S.; Dich, Nadya; Nybo Andersen, Anne-Marie

    2017-01-01

    Background: Parental break-up is wide spread, and the effects of parental break-up on children’s well-being are known. The evidence regarding child age at break-up and subsequent family arrangements is inconclusive. Aim: to estimate the effects of parental break-up on stress in pre-adolescent chi......Background: Parental break-up is wide spread, and the effects of parental break-up on children’s well-being are known. The evidence regarding child age at break-up and subsequent family arrangements is inconclusive. Aim: to estimate the effects of parental break-up on stress in pre......-adolescent children with a specific focus on age at break-up and post-breakup family arrangements. Methods: We used data from the Danish National Birth Cohort. Participants included 44 509 children followed from birth to age 11. Stress was self-reported by children at age 11, when the children also reported...... on parental break-up and post break-up family arrangements. Results: Twenty-one percent of the children had experienced a parental break-up at age 11, and those who had experienced parental break-up showed a higher risk of stress (OR:1.72, 95%CI:1.55;1.91) regardless of the child’s age at break-up. Children...

  7. The effect of spinal manipulation on imbalances in leg strength.

    Science.gov (United States)

    Chilibeck, Philip D; Cornish, Stephen M; Schulte, Al; Jantz, Nathan; Magnus, Charlene R A; Schwanbeck, Shane; Juurlink, Bernhard H J

    2011-09-01

    We hypothesized that spinal manipulation (SM) would reduce strength imbalances between legs. Using an un-blinded randomized design, 28 males and 21 females (54 ± 19y) with at least a 15% difference in isometric strength between legs for hip flexion, extension, abduction, or knee flexion were randomized to treatment or placebo (mock spinal manipulation). Strength of the stronger and weaker legs for hip flexion, extension, abduction, and/or knee flexion was assessed before and after the intervention. SM reduced the relative strength difference between legs for knee flexion (mean ± SD 57 ± 53 to 5 ± 14%) and hip flexion (24 ± 12 to 11 ± 15%) compared to placebo (34 ± 29 to 24 ± 36%, and 20 ± 18 to 22 ± 26%, respectively) (p = 0.05). SM also improved strength in the weak leg for hip abduction (104 ± 43 to 116 ± 43 Nm) compared to placebo (84 ± 24 to 85 ± 31 Nm) (p = 0.03). This study suggests that spinal manipulation may reduce imbalances in strength between legs for knee and hip flexion.

  8. Emphysematous Pyelonephritis Presenting as Necrotizing Fasciitis of the Leg

    Directory of Open Access Journals (Sweden)

    Yu-Xiong Ye

    2009-03-01

    Full Text Available We report a 50-year-old man with poorly controlled diabetes mellitus who presented with a painful, swollen right leg. He had also experienced right flank pain for 1 week prior to admission. Physical examination was notable for tenderness over the right flank. The right leg was diffusely swollen and exquisitely tender to touch, with palpable crepitance. Laboratory tests revealed leukocytosis and pyuria. Computed tomography showed a right ureteral stone with hydronephrosis and characteristic findings of emphysematous pyelonephritis. Furthermore, a right perirenal gas-forming abscess with extension to the right leg was noted. The patient was successfully treated with antibiotic therapy, aggressive control of blood sugar, percutaneous drainage of the hydronephrosis and perirenal abscess, and aggressive debridement of the leg.

  9. Secondary hyperparathyroidism: Uncommon cause of a leg ulcer

    NARCIS (Netherlands)

    van Rijssen, L. B.; Brenninkmeijer, E. E. A.; Nieveen van Dijkum, E. J. M.

    2012-01-01

    Most leg ulcers are vascular based. Only if vascular therapy fails other causes are considered. We report the case of a female with incapacitating leg ulcers caused by a rare condition which was only diagnosed after failing treatment. PRESENTATION OF CASE: The female had an extensive previous

  10. Dipoles on a Two-leg Ladder

    DEFF Research Database (Denmark)

    Gammelmark, Søren; Zinner, Nikolaj Thomas

    2013-01-01

    We study polar molecules with long-range dipole-dipole interactions confined to move on a two-leg ladder for different orientations of the molecular dipole moments with respect to the ladder. Matrix product states are employed to calculate the many-body ground state of the system as function...... that there is a critical angle at which ordering disappears. This angle is slightly larger than the angle at which the dipoles are non-interacting along a single leg. This behavior should be observable using current experimental techniques....

  11. Reasonable designing method for fillet welding leg length

    Energy Technology Data Exchange (ETDEWEB)

    Kiso, T; Michiyuki, T; Nagao, S; Yoshikawa, M; Miyazaki, S

    1976-12-01

    In VLCC and ULCC vessels, the scantling of structural members, especially the thickness of web plate, increases naturally. The present rule of each classification society generally prescribes that welding leg length should be based on the thickness of the web plate. Welding leg length between this web plate and skin plate such as shell plate, deck plate, etc., or face plate, increases according to increase of the thickness of the web plate. We investigated the method to decide reasonable welding leg length and its programming by using the results of finite element method structural analysis, without adhering to the above rule about welding leg length. As a result of applying this method to actual ships under classification societies' approval, the amount of welding decreased by from about 10 percent to 15 percent compared with that required by the above rule. The rationality of the method has been already confirmed by successful results of the application to several vessels in service.

  12. Preliminary Results Of LOCA Problem For APR1400 Reactor

    International Nuclear Information System (INIS)

    Le Dai Dien; Hoang Minh Giang; Le Thi Thu; Vo Thi Huong; Le Van Hong

    2011-01-01

    Several features of NPP with APR1400 nuclear reactor during a loss of coolant accident (LOCA) are investigated in this study. The report describes some main design characteristics of an engineering safety systems of APR1400 and the thermal hydraulic calculation results for steady-state using MARS and RELAP/SCDAPSIM codes. Large Break LOCA accident has been analyzed and evaluated based on acceptable criteria for ECCS given by US NRC. The results from cold leg break LOCA with broken area of 0.0465 m 2 in case of high pressure safety injection system (HPSI) failed to operate or 2 and 4 HPSI pumps are activated. The preliminary results of this work is a part of collaboration between INST researchers and KAERI experts in using RELAP tool for safety analysis of NPPs. (author)

  13. MELCOR based severe accident simulation for WWER-440 type nuclear power plants

    International Nuclear Information System (INIS)

    Vegh, E.; Buerger, L.; Gacs, A.; Gyenes, F.G.; Hozer, Z.; Makovi, P.

    1997-01-01

    SUBA is a MELCOR based severe accident simulator, installed this summer at the Hungarian Nuclear Safety Directorate. In this simulator the thermohydraulics, chemical reactions and material transport in the primary and secondary systems are calculated by the MELCOR code, but the containment, except the cavity, is modelled by the HERMET code, developed in our Institute. The instrumentation and control, the safety systems and the plant logic, are calculated by our models. This paper describes the main features of the used models and presents three different test transients. The presented transients are as follows: a small break LOCA, a cold leg large break LOCA, and the station blackout, without Diesel generators. In each treated transients the most important parameters are presented as time functions and the most significant events are analysed. (author)

  14. Non-thermal production of neutralino cold dark matter from cosmic string decays

    International Nuclear Information System (INIS)

    Jeannerot, R.; Zhang, X.; Brandenberger, R.

    1998-12-01

    We propose a mechanism of nonthermal production of a neutralino cold dark matter particle, χ, from the decay of cosmic strings which form from the spontaneous breaking of a U(1) gauge symmetry, such as U B-L (1), in an extension of the minimal supersymmetric standard model (MSSM). By explicit calculation, we point out that with a symmetry breaking scale η of around 10 8 GeV, the decay of cosmic strings can give rise to Ω χ ≅ 1. This gives a new constraint on supersymmetric models. For example, the dark matter produced from strings will over close the universe if η is near the electroweak symmetry breaking scale. To be consistent with Ω χ ≤ 1, the mass of the new U(1) gauge boson must be much larger than the Fermi scale which makes it unobservable in upcoming accelerator experiments. In a supersymmetric model with an extra U B-L (1) symmetry, the requirement of Ω χ ≤ 1 puts an upper bound on the neutrino mass of about 30eV provided neutrino masses are generated by the see-saw mechanisms. (author)

  15. Effects of immobility on sensory and motor symptoms of restless legs syndrome.

    Science.gov (United States)

    Michaud, Martin; Lavigne, Gilles; Desautels, Alex; Poirier, Gaétan; Montplaisir, Jacques

    2002-01-01

    Restless legs syndrome (RLS) is defined by an irresistible need to move associated with leg paresthesia. Two additional features are essential for diagnosis: (1) worsening of symptoms at rest with temporary relief by activity, and (2) worsening of symptoms during the evening and/or during the night. The suggested immobilization test (SIT) has been developed to evaluate the presence of these criteria. This test quantifies leg movements and leg discomfort during a 1-hour period of immobility prior to bedtime. We used the SIT to evaluate the effects of immobility on leg discomfort and leg movements experienced by 19 patients with RLS and 19 control subjects. Results show that immobility significantly worsens both leg discomfort and periodic leg movements (PLM) in patients with RLS but not in controls. Patients with RLS showed a higher leg discomfort score (32.6 +/- 15.1 mm vs. 5.7 +/- 7.9 mm; P < 0.00001), a greater maximum leg discomfort value (63.4 +/- 27.4 mm vs. 13.7 +/- 23.0 mm; P < 0.00001) and a greater PLM index (88.4 +/- 62.6 vs. 10.4 +/- 20.6; P < 0.00004) than control subjects. These results further validate the use of the SIT as a diagnostic and research tool for RLS and confirm the contention of the International RLS study group that RLS symptoms worsen at rest. Copyright 2001 Movement Disorder Society.

  16. TRAC analysis of design basis events for the accelerator production of tritium target/blanket

    International Nuclear Information System (INIS)

    Lin, J.C.; Elson, J.

    1997-01-01

    A two-loop primary cooling system with a residual heat removal system was designed to mitigate the heat generated in the tungsten neutron source rods inside the rungs of the ladders and the shell of the rungs. The Transient Reactor Analysis Code (TRAC) was used to analyze the thermal-hydraulic behavior of the primary cooling system during a pump coastdown transient; a cold-leg, large-break loss-of-coolant accident (LBLOCA); a hot-leg LBLOCA; and a target downcomer LBLOCA. The TRAC analysis results showed that the heat generated in the tungsten neutron source rods can be mitigated by the primary cooling system for the pump coastdown transient and all the LBLOCAs except the target downcomer LBLOCA. For the target downcomer LBLOCA, a cavity flood system is required to fill the cavity with water at a level above the large fixed headers

  17. Experiment data report for semiscale Mod-1 test S-02-3 (blowdown heat transfer test)

    International Nuclear Information System (INIS)

    Crapo, H.S.; Jensen, M.F.; Sackett, K.E.

    1975-09-01

    Recorded test data are presented for Test S-02-3 of the Semiscale Mod-1 blowdown heat transfer test series. Test S-02-3 was conducted from an initial cold leg fluid temperature of 544 0 F and an initial pressure of 2,263 psig. A simulated double-ended offset shear cold leg break was used to investigate the system response to a depressurization transient with a moderately heated core (75 percent design power level). An electrically heated core was used in the pressure vessel to simulate the effects of a nuclear core. System flow was also set at the 75 percent design level to achieve full core temperature differential. The flow resistance of the intact loop was based on core area scaling. During system depressurization, core power was reduced from the initial level of 1.2 MW in such a manner as to simulate the surface heat flux response of the LOFT nuclear fuel rods until such time that departure from nucleate boiling (DNB) occurs. Blowdown to the pressure suppression system was accomplished without simulated emergency core coolant injection or pressure suppression system coolant spray

  18. Study on entry criteria for severe accident management during hot leg LBLOCAs in a PWR

    International Nuclear Information System (INIS)

    Zhang, Longfei; Zhang, Dafa; Wang, Shaoming

    2007-01-01

    The risk of Large Break Loss of Coolant Accidents (LBLOCA) has been considered an important safety issue since the beginning of the nuclear power industry. The rapid depressurization occurs in the primary coolant circuit when a large break appears in a Pressurized Water Reactors (PWR).Then the coolant temperature reaches saturation at a very low pressure. The core outlet fluid temperatures maybe not reliable indicators of the core damage states at a such lower pressure. The problem is how to decide the time for water injection in the SAM (Severe Accident Management). An alternative entry criterion is the fluid temperature just above the hot channel in which the fluid temperature showed maximum among all the channels. For that reason, a systematic study of entry criterion of SAM for different hot leg break sizes in a 3-loop PWR has been started using the detailed system thermal hydraulic and severe accident analysis code package, RELAP/SCDAPSIM. Best estimate calculations of the large break LOCA of 15 cm, 20 cm and 25 cm without accident managements and in the case of high-pressure safety injection as the accident management were performed in this paper. The analysis results showed that the core exit temperatures are not reliable indicators of the peak core temperatures and core damage states once peak core temperatures reach 1500 K, and the proposed entry criteria for SAM at the time when the core outlet temperature reaches 900 K is not effective to prevent core melt. Then other analyses were performed with a parameter of fluid temperature just above the hot channel. The latter analysis showed that earlier water injection when the fluid temperature just above the hot channel reaches 900 K is effective to prevent further core melt. Since fuel surface and hot channel have spatial distribution and depend on a period of cycle operation, a series of thermocouples are required to install just above the fuel assembly. The maximum exit temperature of 900 K that captured by

  19. Fuel assembly loads during a hypothetical blowdown event in a PWR

    International Nuclear Information System (INIS)

    Stabel, J.; Bosanyi, B.; Kim, J.D.

    1991-01-01

    As a consequence of a hypothetical sudden break of the main coolant pipe of a PWR, RPV-internals and fuel assemblies (FA's) are undergoing horizontal and vertical motions. FA's may impact against each other, against core shroud or against lower core support. The corresponding impact loads must be absorbed by the FA spacer grids and guide thimbles. In this paper FA-loads are calculated with and without consideration of Fluid-Structure-Interaction (FSI) effects for assumed different break sizes of the main coolant pipe. The analysis has been performed for a hypothetical cold leg break of a typical SIEMENS-4 loop plant. For this purpose the codes DAPSY/DAISY (GRS, Germany) were coupled with the structural code KWUSTOSS (SIEMENS). It is shown that the FA loads obtained in calculations with consideration of FSI effects are by a factor of 2-4 lower than those obtained in the corresponding calculations without consideration of FSI. (author)

  20. Leak-before-break experience in CANDU reactors

    International Nuclear Information System (INIS)

    Price, E.G.; Moan, G.D.; Coleman, C.E.

    1988-01-01

    In the Canada deuterium uranium (CANDU) reactor, each of the ∼ 400 hot pressure tubes containing the fuel bundles and the pressurized heat transport water is surrounded and insulated from the cold moderator by a calandria tube. The pressure tubes are made from cold-worked Zr-2.5 Nb with a minimum wall thickness of 4.19 mm, and the calandria tubes are made from annealed Zircaloy-2 with a minimum wall thickness of 1.37 mm. The annulus between these two tubes contains an inert gas. Leak-before-break has developed into an operational tool in CANDU reactors to prevent unstable failure of pressure tubes. A procedure for leak detection and reactor response has been developed from the use of the annulus gas, whose dew point is measured to ascertain if leaks have crept into the annulus. The characteristics of the crack are used to establish the response time for leak detection. The reactor is required to be shut down before the length of the slowly growing crack has reached the critical stage. This critical crack length, determined using slit burst tests on tubes, is the crack length at which the crack growth becomes unstable. The most likely crack growth mechanism is delayed hydride cracking. This mechanism requires three conditions to occur simultaneously: the material must be sensitive to delayed hydride cracking; zirconium hydrides must be present in the material; and the tensile stress must be sufficiently great

  1. [Physical treatment modalities for chronic leg ulcers].

    Science.gov (United States)

    Dissemond, J

    2010-05-01

    An increasing numbers of physical treatment options are available for chronic leg ulcer. In this review article, compression therapy, therapeutic ultrasound, negative pressure therapy, extracorporeal shock wave therapy, electrostimulation therapy, electromagnetic therapy, photodynamic therapy, water-filtered infrared-A-radiation and hydrotherapy are discussed in terms of their practical applications and the underlying evidence. With the exception of compression therapy for most of these treatments, good scientific data are not available. However this is a widespread problem in the treatment of chronic wounds. Nevertheless, several of the described methods such as negative pressure therapy represent one of the gold standards in practical treatment of patients with chronic leg ulcers. Although the use of physical treatment modalities may improve healing in patients with chronic leg ulcers, the diagnosis and treatment of the underlying causes are essential for long-lasting success.

  2. Duality after supersymmetry breaking

    International Nuclear Information System (INIS)

    Shadmi, Yael; Cheng, Hsin-Chia

    1998-05-01

    Starting with two supersymmetric dual theories, we imagine adding a chiral perturbation that breaks supersymmetry dynamically. At low energy we then get two theories with soft supersymmetry-breaking terms that are generated dynamically. With a canonical Kaehler potential, some of the scalars of the ''magnetic'' theory typically have negative mass-squared, and the vector-like symmetry is broken. Since for large supersymmetry breaking the ''electric'' theory becomes ordinary QCD, the two theories are then incompatible. For small supersymmetry breaking, if duality still holds, the magnetic theory analysis implies specific patterns of chiral symmetry breaking in supersymmetric QCD with small soft masses

  3. Sleep board review question: restless legs

    Directory of Open Access Journals (Sweden)

    Omobomi O

    2018-02-01

    Full Text Available No abstract available. Article truncated after 150 words. Ms. Jones (not her real name is a 63-year-old woman who states that she gets very fidgety when sitting in a theater, watching a movie or when flying long distances on a plane. She is unable to find words to describe the sensation but she states that moving her legs make them feel better. Lately, she has been getting this feeling almost every night. She reports no leg discomfort in the daytime. She denies muscle cramps her legs. She had some recent investigations done by her primary care physician because of complaints of fatigue. Which of the following will be helpful in the diagnosis and management in this patient? 1. An overnight polysomnogram showing apnea hypopnea index of 1.6 events per hour and no periodic limb movements (PLMs 2. Ferritin level of 18 ng/ml (normal range 20-200 ng/ml 3. Serum Bicarbonate of 29 mEq/L (normal range 23-29 mEq/L 4. Thyroid …

  4. Cold injuries.

    Science.gov (United States)

    Kruse, R J

    1995-01-01

    There are two categories of cold injury. The first is hypothermia, which is a systemic injury to cold, and the second is frostbite, which is a local injury. Throughout history, entire armies, from George Washington to the Germans on the Russian Front in World War II, have fallen prey to prolonged cold exposure. Cold injury is common and can occur in all seasons if ambient temperature is lower than the core body temperature. In the 1985 Boston Marathon, even though it was 76 degrees and sunny, there were 75 runners treated for hypothermia. In general, humans adapt poorly to cold exposure. Children are at particular risk because of their relatively greater surface area/body mass ratio, causing them to cool even more rapidly than adults. Because of this, the human's best defense against cold injury is to limit his/her exposure to cold and to dress appropriately. If cold injury has occurred and is mild, often simple passive rewarming such as dry blankets and a warm room are sufficient treatment.

  5. Duplex sonography of the near-surface leg veins; Duplexsonographie der oberflaechlichen Beinvenen

    Energy Technology Data Exchange (ETDEWEB)

    Mendoza, E.

    2007-07-01

    The book contains the following contributions: The ultrasonograph, selection of the ultrasonic transducer, anatomy of the near-surface vein system, physiology of the near-surface vein system, varicose status classification, systematics of the duplex sonography of near-surface leg veins, provocational maneuver for the duplex sonographic varicose diagnostics, exploration of vena saphena parva, perforans veins, side branches, phlebitis, sonography for varicose therapy, postsurgical sonography, deep leg veins, examination of near-surface leg veins for the pathology of the deep vein system, differential diagnostic clarification of leg oedema from the phlebologic-lymphological view, diagnostic side features along the near-surface leg veins.

  6. PELATIHAN PLIOMETRIK ALTERNATE LEG BOUND DAN DOUBLE LEG BOUND MENINGKATKAN DAYA LEDAK OTOT TUNGKAI PADA SISWA PUTRA KELAS VII SMP NEGERI 3 SUKAWATI TAHUN PELAJARAN 2012/2013

    Directory of Open Access Journals (Sweden)

    Komang Ayu Tri Widhiyanti

    2013-11-01

    Full Text Available This study was conducted to know the improvement the explosive power of leg muscle. It was done through 5 set 12 repetitions during 6 weeks in the field of SMP Negeri 3 Sukawati started from 4 p.m. until 6 p.m. There were 3 groups applied in this study such as group 1 (control group that was instructed to kick a ball, group 2 (plyometric training of alternate leg bound, and group 3 (plyometric training of double leg bound. The sample was 14 male students who were in the seventh grade class of SMP Negeri 3 Sukawati in the academic year 2012/2013. The data was gained by doing the movement of alternate leg bound and double leg bound that each movement was done three times before and after the training. The hypothesis was examined by using independent t-test with the result 0.05 (p<0.05. Based on the different result of analysis test in each group, the gain score of the group 2 with the group 1 about 0,51 that shows the significant differences p = 0,00, the gain score of the group 2 with the group 3 about 0,31 that shows the significant differences p = 0,00, the gain score of the group 3 with the group 1 about 0,20 that shows the significant differences p = 0,00. Thus, alternate leg bound plyometric training is more effective than double leg bound. It is expected that the coach and the gym teacher to apply alternate leg bound plyometric training as an alternative to improve the explosive power of leg muscle.

  7. Leg kinematics and kinetics in landing from a single-leg hop for distance. A comparison between dominant and non-dominant leg

    NARCIS (Netherlands)

    van der Harst, J. J.; Gokeler, A.; Hof, A. L.

    Background. Anterior cruciate ligament (ACL) deficiency can be a major problem for athletes and subsequent reconstruction of the ACL may be indicated if a conservative regimen has failed. After ACL reconstruction signs of abnormality in the use of the leg remain for a long time. It is expected that

  8. Study of the effect of slight variants to a 3-loop pressurized water nuclear reactor design in order to improve the reactor safety

    International Nuclear Information System (INIS)

    Castiglia, F.; Oliveri, E.; Taibi, S.; Vella, G.

    1992-01-01

    In order to improve the safety features of a 3-loop pressurized water nuclear reactor we propose a slight design variant consisting in the introduction of a bypass hole in the divider plate of the coolant chambers of the steam generators. The aim is to reduce both the extent and the duration of the core exposure and thus the maximum value of the peak cladding temperature, in case of a hypothetical cold leg small break loss of coolant accident. The proposal, as attested by a preliminary RELAP5/MOD3 analysis, seems to deserve some attention. (6 figures) (Author)

  9. Small break LOCA analysis for RCP trip strategy for YGN 3 and 4 emergency procedure guidelines

    International Nuclear Information System (INIS)

    Suh, Jong Tae; Bae, Kyoo Hwan

    1995-01-01

    A continued operation of RCPs during a certain small break LOCA may increase unnecessary inventory loss from the RCS causing a severe core uncovery which might lead to a fuel failure. After TMI-2 accident, the CEOG developed RCP trip strategy called 'Trip-Two/Leave-Two' (T2/L2) in response to NRC requests and incorporated it in the generic EPG for CE plants. The T2/L2 RCP trip strategy consists of tripping the first two RCPs on low RCS pressure and then tripping the remaining two RCPs if a LOCA has occurred. This analysis determines the RCP trip setpoint and demonstrates the safe operational aspects of RCP trip strategy during a small break LOCA for YGN 3 and 4. The trip setpoint of the first two RCPs for YGN 3 and 4 is calculated to be 1775 psia in pressurizer pressure based on the limiting small break LOCA with 0.15 ft 2 break size in the hot leg. The analysis results show that YGN 3 and 4 can maintain the core coolability even if the operator fails to trip the second two RCPs or trips at worst time. Also, the YGN 3 and 4 RCP trip strategy demonstrates that both the 10 CFR 50.46 requirements on PCT and the ANSI standards 58.8 requirements on operator action time can be satisfied with enough margin. Therefore, it is concluded that the T2/L2 RCP trip strategy with a trip setpoint of 1775 psia for YGN 3 and 4 can provide improved operator guidance for the RCP operation during accidents. 11 figs., 4 tabs., 9 refs. (Author)

  10. Backward can extrusion with conical,rotating punch as a cold forging tribology test

    DEFF Research Database (Denmark)

    Ceron, Ermanno; Bay, Niels; Tetsuo, A.

    2011-01-01

    with an analysis of the sliding velocity distribution along the punch nose. The latter is determined by FE analysis of the test. Results show friction stress for unalloyed low C-steel provided with different types of lubricants, e.g. phosphate coating plus soap, phosphate coating plus MoS2 and single bathe...... lubrication with PULS. The new test is so severe, that it is possible to break down the best lubrication systems for cold forging, such as phosphate coating plus soap and MoS2....

  11. Protein Determinants of Meiotic DNA Break Hotspots

    Science.gov (United States)

    Fowler, Kyle R.; Gutiérrez-Velasco, Susana

    2013-01-01

    SUMMARY Meiotic recombination, crucial for proper chromosome segregation and genome evolution, is initiated by programmed DNA double-strand breaks (DSBs) in yeasts and likely all sexually reproducing species. In fission yeast, DSBs occur up to hundreds of times more frequently at special sites, called hotspots, than in other regions of the genome. What distinguishes hotspots from cold regions is an unsolved problem, although transcription factors determine some hotspots. We report the discovery that three coiled-coil proteins – Rec25, Rec27, and Mug20 – bind essentially all hotspots with unprecedented specificity even without DSB formation. These small proteins are components of linear elements, are related to synaptonemal complex proteins, and are essential for nearly all DSBs at most hotspots. Our results indicate these hotspot determinants activate or stabilize the DSB-forming protein Rec12 (Spo11 homolog) rather than promote its binding to hotspots. We propose a new paradigm for hotspot determination and crossover control by linear element proteins. PMID:23395004

  12. Hereditary Lymphedema of the Leg – A Case Report

    Directory of Open Access Journals (Sweden)

    Birgit Heinig

    2017-07-01

    Full Text Available Primary of hereditary lymphedema is a rare but progressive disease. It is yet not curable. We present a 48-year-old male patient with hereditary lymphedema of his left leg, that was realised by minor trauma (able twist when he was seven years old. He had never been treated for lymphedema but experienced multiple erysipelas during his life. After diagnostic procedures to exclude other causes of leg swelling, the diagnosis of hereditary lymphedema of the leg, stage III was confirmed. We initialized complex decongestive therapy. During two weeks of intensive treatment, the circumference of the left leg could be reduced by 10 cm. This case illustrates the "natural course" hereditary lymphedema. But it raises the hope that even after decades of ignorance, the patients benefits from complex decongestive treatment. Therapeutic nihilism is unnecessary and poses lymphedema patients to risks of infection and secondary malignancies like Stewart-Trewes syndrome.

  13. Leg symptoms associated with sacroiliac joint disorder and related pain.

    Science.gov (United States)

    Murakami, Eiichi; Aizawa, Toshimi; Kurosawa, Daisuke; Noguchi, Kyoko

    2017-06-01

    The symptoms of sacroiliac joint (SIJ) disorders are usually detected in the buttock and groin, and occasionally referred to the thigh and leg. However, lumbar disorders also cause symptoms in these same body regions. The presence of a characteristic, symptomatic pattern in the legs would be useful for diagnosing SIJ disorders. This study aimed to identify specific leg symptoms in patients with SIJ pain originating from the posterior sacroiliac ligament and determine the rate of occurrence of these symptoms. The source population consisted of 365 consecutive patients from February 2005 to December 2007. One hundred patients were diagnosed with SIJ pain by a periarticular SIJ injection (42 males and 58 females, average age 46 years, age range, 18-75 years). A leg symptom map was made by subtracting the symptoms after a periarticular SIJ injection from the initial symptoms, and evaluating the rate of each individual symptom by area. Ninety-four patients reported pain at or around the posterior-superior iliac spine (PSIS). Leg symptoms comprised pain and a numbness/tingling sensation; ≥60% of the patients had these symptoms. Pain was mainly detected in the back, buttock, groin, and thigh areas, while numbness/tingling was mainly detected in the lateral to posterior thigh and back of the calf. Leg symptoms associated with SIJ pain originating from the posterior sacroiliac ligament include both pain and numbness, which do not usually correspond to the dermatome. These leg symptoms in addition to pain around the PSIS may indicate SIJ disorders. Copyright © 2017 Elsevier B.V. All rights reserved.

  14. CALCANEAL MINERAL DENSITY IN CHILDREN ATHLETES AND TAKE-OFF LEG

    Directory of Open Access Journals (Sweden)

    Borislav Obradović

    2010-06-01

    Full Text Available It is well-known that physical activity has an anabolic effect on the bone tissue. To examine the influence of the take-off lower limb to the bone density we studied a group of prepubertal boys and girls at the initial phase of their peak bone mass acquisition. A sample consisted of 60 subjects ie., 32 soccer players (boys, 10.7±0.5 years old and 28 swimmers (15 girls and 13 boys, 10.8±0.8 years old, who had performed at least one year of high-level sport training (10-15 hours per week for soccer players, 8-12 hours per week for swimmers. The sample was divided into two groups: the first consisted of 40 subjects, with the left take-off leg, while the second consisted of 20 subjects, with the right take-off leg. The bone mineral density (BMD measurements of the left and the right calcaneus were performed using ultrasound densitometer “Sahara” (Hologic, Inc., MA, USA. There were no significant differences between the groups in regard to BUA and SOS of both the left and the right take-off lower legs. Mean BUA of the take-off left leg and the take-off right leg were different, but not significantly (p>0.05. Likewise, mean SOS of the take-off left leg and the take-off right leg were different, but it was not significant (p>0.05. The results do not indicate that the take-off lower limb has an influence on calcaneal bone mineral density.

  15. The second leg home advantage: evidence from European football cup competitions.

    Science.gov (United States)

    Page, Lionel; Page, Katie

    2007-12-01

    The home advantage is a widely acknowledged sporting phenomenon, especially in association football. Here, we examine the second leg home advantage, an effect that is discussed in the public domain but which has received very little scientific attention. The second leg home advantage effect occurs when on average teams are more likely to win a two-stage knock-out competition when they play at home in the second leg. That is, both teams have a home advantage but this advantage is significantly greater for the team that plays at home second. Examining data from three different European Cup football competitions spanning 51 years, we show that the second leg home advantage is a real phenomenon. The second leg home team has more than a 50% probability to qualify for the next round in the competition even after controlling for extra time and team ability as possible alternative explanations. The second leg home advantage appears, however, to have decreased significantly over the past decade. Possible reasons for its existence and subsequent decline are presented.

  16. Differential glucose uptake in quadriceps and other leg muscles during one-legged dynamic submaximal knee-extension exercise

    DEFF Research Database (Denmark)

    Kalliokoski, Kari K; Boushel, Robert; Langberg, Henning

    2011-01-01

    One-legged dynamic knee-extension exercise (DKE) is a widely used model to study the local cardiovascular and metabolic responses to exercise of the quadriceps muscles. In this study, we explored the extent to which different muscles of the quadriceps are activated during exercise using positron...... emission tomography (PET) determined uptake of [18F]-fluoro-deoxy-glucose (GU) during DKE. Five healthy male subjects performed DKE at 25 W for 35 min and both the contracting and contralateral resting leg were scanned with PET from mid-thigh and distally. On average, exercise GU was the highest...

  17. LMFBR with booster pump in pumping loop

    International Nuclear Information System (INIS)

    Rubinstein, H.J.

    1975-01-01

    A loop coolant circulation system is described for a liquid metal fast breeder reactor (LMFBR) utilizing a low head, high specific speed booster pump in the hot leg of the coolant loop with the main pump located in the cold leg of the loop, thereby providing the advantages of operating the main pump in the hot leg with the reliability of cold leg pump operation

  18. The mangled lower leg

    NARCIS (Netherlands)

    Hoogendoorn, Jochem Maarten

    2002-01-01

    A surgeon faced with a patient presenting with an open tibial/fibular fracture in combination with severe damage of the surrounding soft tissues, has to make the difficult decision whether to attempt salvage or to perform an immediate amputation of the leg. Until late in the nineteenth century the

  19. Locomotor-like leg movements evoked by rhythmic arm movements in humans.

    Directory of Open Access Journals (Sweden)

    Francesca Sylos-Labini

    Full Text Available Motion of the upper limbs is often coupled to that of the lower limbs in human bipedal locomotion. It is unclear, however, whether the functional coupling between upper and lower limbs is bi-directional, i.e. whether arm movements can affect the lumbosacral locomotor circuitry. Here we tested the effects of voluntary rhythmic arm movements on the lower limbs. Participants lay horizontally on their side with each leg suspended in an unloading exoskeleton. They moved their arms on an overhead treadmill as if they walked on their hands. Hand-walking in the antero-posterior direction resulted in significant locomotor-like movements of the legs in 58% of the participants. We further investigated quantitatively the responses in a subset of the responsive subjects. We found that the electromyographic (EMG activity of proximal leg muscles was modulated over each cycle with a timing similar to that of normal locomotion. The frequency of kinematic and EMG oscillations in the legs typically differed from that of arm oscillations. The effect of hand-walking was direction specific since medio-lateral arm movements did not evoke appreciably leg air-stepping. Using externally imposed trunk movements and biomechanical modelling, we ruled out that the leg movements associated with hand-walking were mainly due to the mechanical transmission of trunk oscillations. EMG activity in hamstring muscles associated with hand-walking often continued when the leg movements were transiently blocked by the experimenter or following the termination of arm movements. The present results reinforce the idea that there exists a functional neural coupling between arm and legs.

  20. Experimental Investigation of Tensile Test on Connection of Cold-formed Cut-curved Steel Section

    Science.gov (United States)

    Sani, Mohd Syahrul Hisyam Mohd; Muftah, Fadhluhartini; Rahman, Nurul Farraheeda Abdul; Fakri Muda, Mohd

    2017-08-01

    Cold-formed steel (CFS) is widely used as structural and non-structural components such as roof trusses and purlin. A CFS channel section with double intermediate web stiffener and lipped is chosen based on the broader usage in roof truss construction. CFS section is cut to form cold-formed pre-cut-curved steel section and lastly strengthened by several types of method or likely known as connection to establish the cold-formed cut-curved steel (CFCCS) section. CFCCS is proposed to be used as a top chord section in the roof truss system. The CFCCS is to resist the buckling phenomena of the roof truss structure and reduced the compression effect on the top chord. The tensile test connection of CFCCS section, especially at the flange element with eight types of connection by welding, plate with self-drilling screw and combination is investigated. The flange element is the weakest part that must be solved first other than the web element because they are being cut totally, 100% of their length for curving process. The testing is done using a universal testing machine for a tensile load. From the experiment, specimen with full welding has shown as a good result with an ultimate load of 13.37 kN and reported having 35.41% when compared with normal specimen without any of connection methods. Furthermore, the experimental result is distinguished by using Eurocode 3. The failure of a full welding specimen is due to breaking at the welding location. Additionally, all specimens with either full weld or spot weld or combination failed due to breaking on weld connection, but specimen with flange plate and self-drilling screw failed due to tilting and bearing. Finally, the full welding specimen is chosen as a good connection to perform the strengthening method of CFCCS section.

  1. Peaking cladding temperature and break equivalent size of intermediate break loss of coolant accident

    International Nuclear Information System (INIS)

    Luo Bangqi

    2012-01-01

    The analysis results of intermediate break loss of coolant accident for the nuclear power plant of million kw level showed to be as following: (1) At the begin of life, the break occur simultaneity reactor shutdown with L(X)P. it's equivalent break size and peaking cladding temperature is respectively 20 cm and 849℃. (2) At the begin of life, the break occur simultaneity reactor shutdown without loop. the reactor coolant pumps will be stop after reactor shutdown 10 minutes, it's equivalent break size and peaking cladding temperature is respectively 10.5 cm and 921℃. (3) At the bur up of 31 GWd/t(EOC1). the break occur simultaneity reactor shutdown without loop, the reactor coolant pumps will be stop after reactor shutdown 20 minutes, it's equivalent break size and peaking cladding temperature is respectively 8 cm and 1145℃. The above analysis results showed that the peaking cladding temperature of intermediate break loss of coolant accident is not only related with the break equivalent size and core bur up, and is closely related with the stop time of coolant pumps because the coolant pumps would drive the coolant from safety system to produce the seal loop in break loop and affect the core coolant flow, results in the fuel cladding temperature increasing or damaging. Therefore, the break spectrum, burn up spectrum, the stop time of coolant pumps and operator action time will need to detail analysis and provide appropriate operating procedure, otherwise the peaking cladding temperature will exceed 1204℃ and threaten the safety of the reactor core when the intermediate break loss of coolant accident occur in some break equivalent size, burn up, stop pumps time and operator action not appropriate. The pressurizer pressure low signal simultaneity containment pressure higher signal were used as the operator manual close the signal of reactor coolant pumps after reactor shutdown of 20 minutes. have successful solved the operator intervention time from 10 minutes

  2. Overexpression of a peach CBF gene in apple: a model for understanding the integration of growth, dormancy, and cold hardiness in woody plants

    Science.gov (United States)

    The timing of cold acclimation and de-acclimation, dormancy, and bud break play an integral role in the life cycle of woody plants. The molecular events that regulate these parameters have been the subject of much study, however, in most studies these events have been investigated independently of ...

  3. Orthostatic leg blood volume changes assessed by near-infrared spectroscopy

    DEFF Research Database (Denmark)

    Truijen, J; Kim, Y S; Krediet, C T P

    2012-01-01

    posture, volume accumulation in small blood vessels contributes significantly to the total fluid volume accumulated in the legs. Considering that near-infrared spectroscopy (NIRS) tracks postural blood volume changes within the small blood vessels of the lower leg, we evaluated the NIRS-determined changes......-linear accumulation of blood volume in the small vessels of the leg, with an initial fast phase followed by a more gradual increase at least partly contributing to the relocation of fluid during orthostatic stress....

  4. Eyelash Transplantation Using Leg Hair by Follicular Unit Extraction

    Directory of Open Access Journals (Sweden)

    Sanusi Umar, MD

    2015-03-01

    Full Text Available Summary: Fine hairs of the head and nape areas have been used as donor sources in eyelash transplantation but are straight, coarse, and grow rapidly, requiring frequent eyelash maintenance. This is the first reported case of eyelash transplantation by follicular unit extraction using leg hair as a donor source; findings were compared with that of another patient who underwent a similar procedure with donor hairs from the nape area. Although both patients reported marked improvement in fullness of eyelashes within 3 months postsurgery, the transplanted leg hair eyelashes required less frequent trimming (every 5–6 weeks compared with nape hair eyelashes (every 2–3 weeks. Additionally, in leg hair eyelashes, the need for perming to sustain a natural looking eyelash curl was eliminated. Eyelash transplantation using leg donor hair in hirsute women may result in good cosmetic outcomes and require less maintenance compared with nape donor hair.

  5. Sleep apnea in patients reporting insomnia or restless legs symptoms.

    Science.gov (United States)

    Bianchi, M T; Goparaju, B; Moro, M

    2016-01-01

    Insomnia and restless legs syndrome (RLS) are defined by self-reported symptoms, and polysomnography (PSG) is not routinely indicated. Occult obstructive sleep apnea (OSA), common even in asymptomatic adults, may complicate management of patients presenting with insomnia or restless legs. To this end, we investigated objective sleep apnea metrics in a large retrospective cohort according to self-reported symptom profiles. We compared sleep apnea findings in patients referred to our center according to self-reported symptoms associated with insomnia, sleep apnea, and restless legs. The cohort included over 1900 adults who underwent diagnostic (n = 1418) or split-night (n = 504) PSGs and completed a symptom and medical history questionnaire. More than 30% of patients who did not endorse any OSA symptoms, but did endorse insomnia or restless legs symptoms, were found to have OSA based on apnea-hypopnea index (AHI) >5 during overnight laboratory testing. Regression models of the full cohort showed that the risk of OSA was related, as expected, to older age, male sex, elevated body mass index, and presence of OSA symptoms. The presence of insomnia symptoms did not alter the risk of OSA. The presence of restless legs symptoms showed a small odds ratio for lowered OSA risk. Objective evidence of OSA occurs similarly in those with insomnia or restless legs symptoms, even among those without self-reported OSA symptoms. Providers should be aware of the potential for occult OSA in populations with insomnia and restless legs, which may complicate their management in addition to presenting an independent medical risk itself. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  6. Assessment of nutritional status in adult patients with cystic fibrosis: whole-body bioimpedance vs body mass index, skinfolds, and leg-to-leg bioimpedance

    NARCIS (Netherlands)

    Hollander, F.M.; Roos, de N.M.; Vries, de J.H.M.; Berkhout, van F.T.

    2005-01-01

    Objective: To investigate whether body mass index (BMI) or body fat percentage estimated from BMI, skinfolds, or leg-to-leg bioimpedance are good indicators of nutritional status in adult patients with cystic fibrosis. Body fat percentage measured by whole-body bioimpedance was used as the reference

  7. Sensitivity of sensor-based sit-to-stand peak power to the effects of training leg strength, leg power and balance in older adults

    NARCIS (Netherlands)

    Regterschot, G Ruben H; Folkersma, Marjanne; Zhang, Wei; Baldus, Heribert; Stevens, Martin; Zijlstra, Wiebren

    Increasing leg strength, leg power and overall balance can improve mobility and reduce fall risk. Sensor-based assessment of peak power during the sit-to-stand (STS) transfer may be useful for detecting changes in mobility and fall risk. Therefore, this study investigated whether sensor-based STS

  8. Analysis of three ex-vessel loss-of-coolant accidents in the first wall cooling system of NET/ITER

    International Nuclear Information System (INIS)

    Komen, E.M.J.; Koning, H.

    1993-01-01

    An ex-vessel LOCA may be caused by a rupture of a cooling pipe located outside the vacuum vessel. No plasma shutdown and no other counteractions have been assumed in order to study the worst case conditions of the accidents. The next three ex-vessel LOCAs in the primary cooling system of the first wall have been analysed: 1. a large break ex-vessel LOCA caused by a rupture of the cold leg (inner diameter 0.314 m) of the main circuit; 2. an intermediate break ex-vessel LOCA caused by a rupture of a sector inlet feeder (inner diameter 0.158 m); 3. an intermediate break ex-vessel LOCA caused by a rupture of the surge line (inner diameter 0.180 m) of the pressurizer. The analyses have been performed using the thermal-hydraulic system analysis code RELAP5/MOD3. In the first two scenarios, melting in the first wall starts about 90 s after break initiation. In the third scenario, melting in the first wall start about 323 s after break initiation. Special emphasis has been paid to the characteristics of the break flows, the transient thermal-hydraulic behaviour of the cooling system, and the temperature development in the first wall. (orig.)

  9. MARS-KS code validation activity through the atlas domestic standard problem

    International Nuclear Information System (INIS)

    Choi, K. Y.; Kim, Y. S.; Kang, K. H.; Park, H. S.; Cho, S.

    2012-01-01

    The 2 nd Domestic Standard Problem (DSP-02) exercise using the ATLAS integral effect test data was executed to transfer the integral effect test data to domestic nuclear industries and to contribute to improving the safety analysis methodology for PWRs. A small break loss of coolant accident of a 6-inch break at the cold leg was determined as a target scenario by considering its technical importance and by incorporating interests from participants. Ten calculation results using MARS-KS code were collected, major prediction results were described qualitatively and code prediction accuracy was assessed quantitatively using the FFTBM. In addition, special code assessment activities were carried out to find out the area where the model improvement is required in the MARS-KS code. The lessons from this DSP-02 and recommendations to code developers are described in this paper. (authors)

  10. Experimental research on pressurized water reactor(PWR) safety

    International Nuclear Information System (INIS)

    Kim, Dong Su; Chae, Sung Ki; Chang, Won Pyo

    1991-12-01

    The objective of this research is to analyze the experimental results already performed in BETHSY facility of CEA France and to establish essential technologies for the future implementation of both such an experiment and computer code assessment, which are not undergoing in Korea so far. The contents of the present study are divided into 2 categories; namely, analysis of the BETHSY experimental data received from CEA, and CATHARE computer code simulation for the selected experiments, i.e. 'Natural Circulation(Test 4.3a)' and '2 Cold Leg Break'. The later studies are performed under the aims of CATHARE assessment as well as qualification of KOSAC code developing at KAERI, which is the subject in the next year and will concern an adequacy of KOSAC for the prediction of low flow natural circulation and a small break transients. (Author)

  11. Cold plate

    Energy Technology Data Exchange (ETDEWEB)

    Marroquin, Christopher M.; O' Connell, Kevin M.; Schultz, Mark D.; Tian, Shurong

    2018-02-13

    A cold plate, an electronic assembly including a cold plate, and a method for forming a cold plate are provided. The cold plate includes an interface plate and an opposing plate that form a plenum. The cold plate includes a plurality of active areas arranged for alignment over respective heat generating portions of an electronic assembly, and non-active areas between the active areas. A cooling fluid flows through the plenum. The plenum, at the non-active areas, has a reduced width and/or reduced height relative to the plenum at the active areas. The reduced width and/or height of the plenum, and exterior dimensions of cold plate, at the non-active areas allow the non-active areas to flex to accommodate surface variations of the electronics assembly. The reduced width and/or height non-active areas can be specifically shaped to fit between physical features of the electronics assembly.

  12. BETHSY ISP-38 flow behaviour in hot leg

    International Nuclear Information System (INIS)

    Petelin, S.; Jurkovic, M.

    1998-01-01

    Betsy Test 6.9c OECD ISP-38 RELAP5/MOD3.2 input model was developed and simulation performed for loss of RHR system during mid-loop operation. Initial liquid level in RCS was at horizontal axis of the hot legs. Pressurizer and steam generator manways were opened 1 s after the transient was initiated. Secondary side is full of air and isolated. Results of calculations were satisfied except in surge line and in pressurizer where larger amount of water is presented. Liquid was entrained in that part of the system during bubbly or varies stratified flow in the hot leg. Due to non-physical results in hot leg pipe with connected surge line and pressurizer, RELAP5 horizontal stratification model deficiencies was studied and possible improvements investigated.(author)

  13. [Fractures of the lower leg in professional skiers].

    Science.gov (United States)

    Mückley, T; Kruis, C; Schütz, T; Brucker, P; Bühren, V

    2004-03-01

    Fractures of the lower leg due to skiing accidents remain an important concern. Few studies have focussed on the special demands of professional athletes who sustain these injuries. We present our experience with three cases of lower leg fractures in competitive professional downhill skiers and discuss management and treatment concepts. We performed limited reamed compression nailing in all the patients presented because it offers the advantages of high mechanical stability and optimized fragment apposition. Plate osteosynthesis of the fibula is not required in most typical fractures. All patients resumed ski training. Two of them returned to World Cup. Only one achieved her pre-injury World Cup level of performance and success. In conclusion, a successful return for professional skiers with lower leg fractures is feasible using an optimized treatment strategy.

  14. Laboratory on Legs: An Architecture for Adjustable Morphology with Legged Robots

    Science.gov (United States)

    2012-04-01

    including walking, running,7 pronking,8,9 leaping and flipping,10 climbing stairs ,11,12 recovering from failures,13 and even running upright on (modified...speed activities requiring large leg torques, such as clambering over rocks and climbing stairs , as well as high speed activities with moderate torques...8] McMordie, D. and Buehler, M., “Towards pronking with a hexapod robot ,” in [International Conference on Climbing and Walking Robots

  15. Arm and leg substrate utilization and muscle adaptation after prolonged low-intensity training

    DEFF Research Database (Denmark)

    Helge, Jørn Wulff

    2010-01-01

    This review will focus on current data where substrate metabolism in arm and leg muscle is investigated and discuss the presence of higher carbohydrate oxidation and lactate release observed during arm compared with leg exercise. Furthermore, a basis for a possible difference in substrate partiti...... at comparable workloads. Finally, the influence and capacity of low-intensity training to influence metabolic fitness in the face of a limited effect on aerobic fitness will be challenged....... partitioning between endogenous and exogenous substrate during arm and leg exercise will be debated. Moreover the review will probe if differences between arm and leg muscle are merely a result of different training status rather than a qualitative difference in limb substrate regulation. Along this line...... the review will address the available studies on low-intensity training performed separately with arm or legs or as whole-body training to evaluate if this leads to different adaptations in arm and leg muscle resulting in different substrate utilization patterns during separate arm or leg exercise...

  16. Multi-Axis Prosthetic Knee Resembles Alpine Skiing Movements of an Intact Leg

    Science.gov (United States)

    Demšar, Ivan; Duhovnik, Jože; Lešnik, Blaž; Supej, Matej

    2015-01-01

    The purpose of the study was to analyse the flexion angles of the ski boot, ankle and knee joints of an above-knee prosthesis and to compare them with an intact leg and a control group of skiers. One subject with an above-knee amputation of the right leg and eight healthy subjects simulated the movement of a skiing turn by performing two-leg squats in laboratory conditions. By adding additional loads in proportion to body weight (BW; +1/3 BW, +2/3 BW, +3/3 BW), various skiing regimes were simulated. Change of Flexion Angle (CoFA) and Range of Motion (RoM) in the ski boot, ankle and knee joints were calculated and compared. An average RoM in the skiing boot on the side of prosthesis (4.4 ± 1.1°) was significantly lower compared to an intact leg (5.9 ± 1.8°) and the control group (6.5 ± 2.3°). In the ankle joint, the average RoM was determined to be 13.2±2.9° in the prosthesis, 12.7 ± 2.8° in an intact leg and 14.8±3.6 in the control group. However, the RoM of the knee joint in the prosthesis (42.2 ± 4.2°) was significantly larger than that of the intact leg (34.7 ± 4.4°). The average RoM of the knee joint in the control group was 47.8 ± 5.4°. The influences of additional loads on the kinematics of the lower extremities were different on the side of the prosthesis and on the intact leg. In contrast, additional loads did not produce any significant differences in the control group. Although different CoFAs in the ski boot, ankle and knee joints were used, an above-knee prosthesis with a built-in multi-axis prosthetic knee enables comparable leg kinematics in simulated alpine skiing. Key points The RoM in the ski boot on the side of the prosthetic leg was smaller than the RoM of the intact leg and the control group of healthy subjects. The RoM in the ankle joint of prosthetic leg was comparable to that of the intact leg and the control group of healthy subjects. The RoM in the prosthetic knee joint was greater than the RoM in the knee joint of the

  17. Parental smoking during pregnancy shortens offspring's legs.

    Science.gov (United States)

    Żądzińska, E; Kozieł, S; Borowska-Strugińska, B; Rosset, I; Sitek, A; Lorkiewicz, W

    2016-12-01

    One of the most severe detrimental environmental factors acting during pregnancy is foetal smoke exposure. The aim of this study was to assess the effect of maternal, paternal and parental smoking during pregnancy on relative leg length in 7- to 10-year-old children. The research conducted in the years 2001-2002 included 978 term-born children, 348 boys and 630 girls, at the age of 7-10 years. Information concerning the birth weight of a child was obtained from the health records of the women. Information about the mother's and the father's smoking habits during pregnancy and about the mothers' education level was obtained from a questionnaire. The influence of parental smoking on relative leg length, controlled for age, sex, birth weight and the mother's education, as a proxy measure of socioeconomic status, and controlled for an interaction between sex and birth weight, was assessed by an analysis of covariance, where relative leg length was the dependent variable, smoking and sex were the independent variables, and birth weight as well as the mother's education were the covariates. Three separate analyses were run for the three models of smoking habits during pregnancy: the mother's smoking, the father's smoking and both parents' smoking. Only both parents' smoking showed a significant effect on relative leg length of offspring. It is probable that foetal hypoxia caused by carbon monoxide contained in smoke decelerated the growth of the long bones of foetuses. Copyright © 2016 Elsevier GmbH. All rights reserved.

  18. Design of a Single Motor Based Leg Structure with the Consideration of Inherent Mechanical Stability

    Science.gov (United States)

    Taha Manzoor, Muhammad; Sohail, Umer; Noor-e-Mustafa; Nizami, Muhammad Hamza Asif; Ayaz, Yasar

    2017-07-01

    The fundamental aspect of designing a legged robot is constructing a leg design that is robust and presents a simple control problem. In this paper, we have successfully designed a robotic leg based on a unique four bar mechanism with only one motor per leg. The leg design parameters used in our platform are extracted from design principles used in biological systems, multiple iterations and previous research findings. These principles guide a robotic leg to have minimal mechanical passive impedance, low leg mass and inertia, a suitable foot trajectory utilizing a practical balance between leg kinematics and robot usage, and the resultant inherent mechanical stability. The designed platform also exhibits the key feature of self-locking. Theoretical tools and software iterations were used to derive these practical features and yield an intuitive sense of the required leg design parameters.

  19. Increase in Leg Stiffness Reduces Joint Work During Backpack Carriage Running at Slow Velocities.

    Science.gov (United States)

    Liew, Bernard; Netto, Kevin; Morris, Susan

    2017-10-01

    Optimal tuning of leg stiffness has been associated with better running economy. Running with a load is energetically expensive, which could have a significant impact on athletic performance where backpack carriage is involved. The purpose of this study was to investigate the impact of load magnitude and velocity on leg stiffness. We also explored the relationship between leg stiffness and running joint work. Thirty-one healthy participants ran overground at 3 velocities (3.0, 4.0, 5.0 m·s -1 ), whilst carrying 3 load magnitudes (0%, 10%, 20% weight). Leg stiffness was derived using the direct kinetic-kinematic method. Joint work data was previously reported in a separate study. Linear models were used to establish relationships between leg stiffness and load magnitude, velocity, and joint work. Our results found that leg stiffness did not increase with load magnitude. Increased leg stiffness was associated with reduced total joint work at 3.0 m·s -1 , but not at faster velocities. The association between leg stiffness and joint work at slower velocities could be due to an optimal covariation between skeletal and muscular components of leg stiffness, and limb attack angle. When running at a relatively comfortable velocity, greater leg stiffness may reflect a more energy efficient running pattern.

  20. 33 CFR 147.817 - Sir Douglas Morpeth Tension Leg Platform safety zone.

    Science.gov (United States)

    2010-07-01

    ... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false Sir Douglas Morpeth Tension Leg... HOMELAND SECURITY (CONTINUED) OUTER CONTINENTAL SHELF ACTIVITIES SAFETY ZONES § 147.817 Sir Douglas Morpeth Tension Leg Platform safety zone. (a) Description. The Sir Douglas Morpeth Tension Leg Platform (Morpeth...

  1. In pursuit of vehicle landmine occupant protection: Evaluating the dynamic response characteristic of the military lower extremity leg (MiL-Lx) compared to the Hybrid III (HIII) lower leg

    CSIR Research Space (South Africa)

    Pandelani, T

    2010-09-01

    Full Text Available typical mine-protected vehicle landmine blast load conditions. Tests were performed using the Lower Limb Impactor (LLI) on both the MiL-Lx leg and the Hybrid III leg, and the relative responses compared. The results show that the MiL-Lx leg appears...

  2. Reproducibility and day time bias correction of optoelectronic leg volumetry: a prospective cohort study.

    Science.gov (United States)

    Engelberger, Rolf P; Blazek, Claudia; Amsler, Felix; Keo, Hong H; Baumann, Frédéric; Blättler, Werner; Baumgartner, Iris; Willenberg, Torsten

    2011-10-05

    Leg edema is a common manifestation of various underlying pathologies. Reliable measurement tools are required to quantify edema and monitor therapeutic interventions. Aim of the present work was to investigate the reproducibility of optoelectronic leg volumetry over 3 weeks' time period and to eliminate daytime related within-individual variability. Optoelectronic leg volumetry was performed in 63 hairdressers (mean age 45 ± 16 years, 85.7% female) in standing position twice within a minute for each leg and repeated after 3 weeks. Both lower leg (legBD) and whole limb (limbBF) volumetry were analysed. Reproducibility was expressed as analytical and within-individual coefficients of variance (CVA, CVW), and as intra-class correlation coefficients (ICC). A total of 492 leg volume measurements were analysed. Both legBD and limbBF volumetry were highly reproducible with CVA of 0.5% and 0.7%, respectively. Within-individual reproducibility of legBD and limbBF volumetry over a three weeks' period was high (CVW 1.3% for both; ICC 0.99 for both). At both visits, the second measurement revealed a significantly higher volume compared to the first measurement with a mean increase of 7.3 ml ± 14.1 (0.33% ± 0.58%) for legBD and 30.1 ml ± 48.5 ml (0.52% ± 0.79%) for limbBF volume. A significant linear correlation between absolute and relative leg volume differences and the difference of exact day time of measurement between the two study visits was found (P correction formula permitted further improvement of CVW. Leg volume changes can be reliably assessed by optoelectronic leg volumetry at a single time point and over a 3 weeks' time period. However, volumetry results are biased by orthostatic and daytime-related volume changes. The bias for day-time related volume changes can be minimized by a time-correction formula.

  3. Reproducibility and day time bias correction of optoelectronic leg volumetry: a prospective cohort study

    Directory of Open Access Journals (Sweden)

    Baumgartner Iris

    2011-10-01

    Full Text Available Abstract Background Leg edema is a common manifestation of various underlying pathologies. Reliable measurement tools are required to quantify edema and monitor therapeutic interventions. Aim of the present work was to investigate the reproducibility of optoelectronic leg volumetry over 3 weeks' time period and to eliminate daytime related within-individual variability. Methods Optoelectronic leg volumetry was performed in 63 hairdressers (mean age 45 ± 16 years, 85.7% female in standing position twice within a minute for each leg and repeated after 3 weeks. Both lower leg (legBD and whole limb (limbBF volumetry were analysed. Reproducibility was expressed as analytical and within-individual coefficients of variance (CVA, CVW, and as intra-class correlation coefficients (ICC. Results A total of 492 leg volume measurements were analysed. Both legBD and limbBF volumetry were highly reproducible with CVA of 0.5% and 0.7%, respectively. Within-individual reproducibility of legBD and limbBF volumetry over a three weeks' period was high (CVW 1.3% for both; ICC 0.99 for both. At both visits, the second measurement revealed a significantly higher volume compared to the first measurement with a mean increase of 7.3 ml ± 14.1 (0.33% ± 0.58% for legBD and 30.1 ml ± 48.5 ml (0.52% ± 0.79% for limbBF volume. A significant linear correlation between absolute and relative leg volume differences and the difference of exact day time of measurement between the two study visits was found (P W. Conclusions Leg volume changes can be reliably assessed by optoelectronic leg volumetry at a single time point and over a 3 weeks' time period. However, volumetry results are biased by orthostatic and daytime-related volume changes. The bias for day-time related volume changes can be minimized by a time-correction formula.

  4. Whole body and local cryotherapy in restless legs syndrome: A randomized, single-blind, controlled parallel group pilot study.

    Science.gov (United States)

    Happe, Svenja; Evers, Stefan; Thiedemann, Christian; Bunten, Sabine; Siegert, Rudolf

    2016-11-15

    Treatment of restless legs syndrome (RLS) is primarily based on drugs. Since many patients report improvement of symptoms due to cooling their legs, we examined the efficacy of cryotherapy in RLS. 35 patients (28 women, 60.9±12.5years) with idiopathic RLS and symptoms starting not later than 6pm were randomized into three groups: cold air chamber at -60°C (n=12); cold air chamber at -10°C (n=12); local cryotherapy at -17°C (n=11). After a two week baseline, the different therapies were applied three minutes daily at 6pm over two weeks, followed by a four week observation period. The patients completed several questionnaires regarding RLS symptoms, sleep, and quality of life on a weekly basis (IRLS, ESS), VAS and sleep/morning protocol were completed daily, MOSS/RLS-QLI were completed once in each period. Additionally, the PLM index was measured by a mobile device at the end of baseline, intervention, and follow-up. The IRLS score was chosen as primary efficacy parameter. At the end of follow-up, significant improvement of RLS symptoms and quality of life could be observed only in the -60°C group as compared to baseline (IRLS: p=0.009; RLS-QLI: p=0.006; ESS: p=0.020). Local cryotherapy led to improvement in quality of life (VAS4: p=0.028; RLS-QLI: p=0.014) and sleep quality (MOSS: p=0.020; MOSS2: p=0.022) but not in IRLS and ESS. In the -10°C group, the only significant effect was shortening of number of wake phases per night. Serious side-effects were not reported. Whole body cryotherapy at -60°C and, to a less extent, local cryotherapy seem to be a treatment option for RLS in addition to conventional pharmacological treatment. However, the exact mode of cryotherapy needs to be established. Copyright © 2016. Published by Elsevier B.V.

  5. Ultrasonography of Skin Changes in Legs with Chronic Venous Disease.

    Science.gov (United States)

    Caggiati, A

    2016-10-01

    In daily practice, ultrasonography (US) is used only to designate the location and pattern of venous lesions. Skin US is not performed between routine venous investigations. Skin morphology is evaluated by the same probes used for routine Duplex evaluation of superficial veins. US findings from evident skin lesions are comparatively evaluated with those from the surrounding apparently normal skin and from the contralateral leg. Inflammation and dermal edema can be found in the apparently normal skin of C2 legs. Swollen legs show thickening of the subcutaneous layer as a result of diffuse soaking or anechoic cavities, with or without dermal edema. Chronic hypodermitis is characterized by inflammatory edema in initial phases, and by liposclerosis in advanced cases. Recrudescence of inflammation provokes focal rarefactions of the subcutaneous layer, possibly related to ulcer opening. In legs with venous disorders, sonography refines clinical evaluation of the skin and may reveal changes not highlighted by inspection. Some of these changes could require further investigation because they have not yet been explained or described. Skin sonography should improve knowledge of the natural history of skin changes, as well as contribute to a better grading of venous diseases severity In particular, US evidence of cutaneous and subcutaneous changes in C2 legs should be considered to stratify the treatment in C2 legs, by identifying those in which varicose veins are not simply a cosmetic problem. Copyright © 2016 European Society for Vascular Surgery. Published by Elsevier Ltd. All rights reserved.

  6. Conceptualizing Cold Disasters

    DEFF Research Database (Denmark)

    Lauta, Kristian Cedervall; Dahlberg, Rasmus; Vendelø, Morten Thanning

    2017-01-01

    In the present article, we explore in more depth the particular circumstances and characteristics of governing what we call ‘cold disasters’, and thereby, the paper sets out to investigate how disasters in cold contexts distinguish themselves from other disasters, and what the implications hereof...... are for the conceptualization and governance of cold disasters. Hence, the paper can also be viewed as a response to Alexander’s (2012a) recent call for new theory in the field of disaster risk reduction. The article is structured in four overall parts. The first part, Cold Context, provides an overview of the specific...... conditions in a cold context, exemplified by the Arctic, and zooms in on Greenland to provide more specific background for the paper. The second part, Disasters in Cold Contexts, discusses “cold disasters” in relation to disaster theory, in order to, elucidate how cold disasters challenge existing...

  7. Monocoque structure for the SKITTER three-legged walker

    Science.gov (United States)

    Bansek, Robert N.; Booth, Andrew J.; Daneman, Steven A.; Dresser, James A.; Haney, Todd G.; Johnson, Gregory R.; Lindzen, Eric C.; Montgomery, Robert C.; Warren, Andrew L.

    1988-01-01

    The SKITTER 2 design is a monocoque version of the proposed lunar three-legged walker. By the definition of monocoque, the body and legs are a shell with no internal ribbing or supports added for absorbing stresses. The purpose of the monocoque is to encase the elements used for power transmission, power supply, and control of the motion. The material for the structure is a vinyl ester resin, Derakane 8084. This material is easily formable and locally obtainable. The body consists of a hexagonally shaped cylinder with truncated hexagonal pyramids on the top and botton. The legs are eight inch diameter cylinders. The legs are comprised of a tibia section and a femur section. The SKITTER 2 is powered by six actuators which provide linear forces that are transformed into rotary torques by a series of chains and sprockets. The joints connect the femur to the body and the tibia to the femur. Surrounding the joints are flexible rubber hoses that fully encase the chains and sprockets. The SKITTER 2 is capable of walking upside down, righting itself after being overturned, and has the ability to perform in many environments. Applications for this walker include lunar transport or drilling, undersea exploration, and operation in severe surroundings such as arctic temperatures or high radiation.

  8. PWR hot leg natural circulation modeling with MELCOR code

    Energy Technology Data Exchange (ETDEWEB)

    Park, Jae Hong; Lee, Jong In [Korea Institute of Nuclear Safety, Taejon (Korea, Republic of)

    1998-12-31

    Previous MELCOR and SCDAP/RELAP5 nodalizations for simulating the counter-current, natural circulation behavior of vapor flow within the RCS hot legs and SG U-tubes when core damage progress can not be applied to the steady state and water-filled conditions during the initial period of accident progression because of the artificially high loss coefficients in the hot legs and SG U-tubes which were chosen from results of COMMIX calculation and the Westinghouse natural circulation experiments in a 1/7-scale facility for simulating steam natural circulation behavior in the vessel and circulation modeling which can be used both for the liquid flow condition at steady state and for the vapor flow condition at the later period of in-vessel core damage. For this, the drag forces resulting from the momentum exchange effects between the two vapor streams in the hot leg was modeled as a pressure drop by pump model. This hot leg natural circulation modeling of MELCOR was able to reproduce similar mass flow rates with those predicted by previous models. 6 refs., 2 figs. (Author)

  9. PWR hot leg natural circulation modeling with MELCOR code

    Energy Technology Data Exchange (ETDEWEB)

    Park, Jae Hong; Lee, Jong In [Korea Institute of Nuclear Safety, Taejon (Korea, Republic of)

    1997-12-31

    Previous MELCOR and SCDAP/RELAP5 nodalizations for simulating the counter-current, natural circulation behavior of vapor flow within the RCS hot legs and SG U-tubes when core damage progress can not be applied to the steady state and water-filled conditions during the initial period of accident progression because of the artificially high loss coefficients in the hot legs and SG U-tubes which were chosen from results of COMMIX calculation and the Westinghouse natural circulation experiments in a 1/7-scale facility for simulating steam natural circulation behavior in the vessel and circulation modeling which can be used both for the liquid flow condition at steady state and for the vapor flow condition at the later period of in-vessel core damage. For this, the drag forces resulting from the momentum exchange effects between the two vapor streams in the hot leg was modeled as a pressure drop by pump model. This hot leg natural circulation modeling of MELCOR was able to reproduce similar mass flow rates with those predicted by previous models. 6 refs., 2 figs. (Author)

  10. Dynamically Stable Legged Locomotion.

    Science.gov (United States)

    1983-01-27

    digitai~y thro)ugh a ribbon cable. lhe dcsign effort required to mount power sources and computing u(m board would hive distracted us fiorn our main...angular momentum. "The model used in this paper, shown in Fig. 6-1, has 3 single springy leg that articular •s ,ith respect to a body about a simple hince

  11. Postural control of typical developing boys during the transition from double-leg stance to single-leg stance.

    Science.gov (United States)

    Deschamps, Kevin; Staes, Filip; Peerlinck, Kathelijne; Van Geet, Kristel; Hermans, Cedric; Lobet, Sebastien

    2017-02-01

    Literature is lacking information about postural control performance of typically developing children during a transition task from double-leg stance to single-leg stance. The purpose of the present study was therefore to evaluate the clinical feasibility of a transition task in typical developing age groups as well as to study the correlation between associated balance measures and age.Thirty-three typically developing boys aged 6-20 years performed a standard transition task from DLS to SLS with eyes open (EO) and eyes closed (EC). Balance features derived from the center of pressure displacement captured by a single force platform were correlated with age on the one hand and considered for differences in the perspective of limb dominance on the other hand.All TDB (typically developing boys) were able to perform the transition task with EO. With respect to EC condition, all TDB from the age group 6-7 years and the youngest of the age group 8-12 years (N = 4) were unable to perform the task. No significant differences were observed between the balance measures of the dominant and non-dominant limbs.With respect to EO condition, correlation analyses indicated that time to new stability point (TNSP) as well as the sway measure after this TNSP were correlated with age (p postural balance of typically developing children during walking, running, sit-to-stand, and bipodal and unipodal stance has been well documented in the literature. • These reference data provided not only insight into the maturation process of the postural control system, but also served in diagnosing and managing functional repercussions of neurological and orthopedic pathologies. What is New: • Objective data regarding postural balance of typical developing children during a transition task from double-leg stance to single-leg stance. • Insight into the role of maturation on the postural control system.

  12. Leak-before-break concept for evaluation of flows detected in pressure tubes in a Candu type reactor

    International Nuclear Information System (INIS)

    Crespi, J.C.

    1992-01-01

    This paper reviews the role of the Leak-Before-Break concept for evaluation of flaws detected in cold-worked Zr 2.5% Nb pressure tubes in a CANDU type reactors. The acceptance criteria are intended to prevent failure by brittle fracture, plastic collapse of the ligament and delayed hydride cracking. The methodology developed here was of great help in order to establish the operative conditions for fuel channel garter springs repositioning by means of the SLA Rette tool at Embalse Nuclear Generating Station, Cordoba, Argentina. (author)

  13. Fatal pox infection in a rough-legged hawk

    Science.gov (United States)

    Pearson, G.L.; Pass, D.A.; Beggs, E.C.

    1975-01-01

    Natural pox infection occurred in a free-living rough-legged hawk (Buteo lagopus) in northeastern North Dakota. Gross, histological and electron microscopic findings were typical of pox infection, and characteristic lesions developed in red-tailed hawks (Buteo jamaicensis) but not in great horned owls (Bubo virginianus) following inoculation with case material. Death of the rough-legged hawk was attributed to starvation resulting from inability to capture prey and to blood loss from foot lesions.

  14. Dynamical supersymmetry breaking

    International Nuclear Information System (INIS)

    Affleck, I.

    1985-03-01

    Supersymmetry, and in particular, dynamical supersymmetry breaking, offers the hope of a natural solution of the gauge hierarchy problem in grand unification. I briefly review recent work on dynamical supersymmetry breaking in four-dimensional Higgs theories and its application to grand unified model building

  15. Breaking of ocean surface waves

    International Nuclear Information System (INIS)

    Babanin, A.V.

    2009-01-01

    Wind-generated waves are the most prominent feature of the ocean surface, and so are breaking waves manifested by the appearance of sporadic whitecaps. Such breaking represents one of the most interesting and most challenging problems for both fluid mechanics and physical oceanography. It is an intermittent random process, very fast by comparison with other processes in the wave breaking on the water surface is not continuous, but its role in maintaining the energy balance within the continuous wind-wave field is critical. Ocean wave breaking also plays the primary role in the air-sea exchange of momentum, mass and heat, and it is of significant importance for ocean remote sensing, coastal and maritime engineering, navigation and other practical applications. Understanding the wave breaking its occurrence, the breaking rates and even ability to describe its onset has been hindered for decades by the strong non-linearity of the process, together with its irregular and ferocious nature. Recently, this knowledge has significantly advanced, and the review paper is an attempt to summarise the facts into a consistent, albeit still incomplete picture of the phenomenon. In the paper, variety of definitions related to the were breaking are discussed and formulated and methods for breaking detection and measurements are examined. Most of attention is dedicated to the research of wave breaking probability and severity. Experimental, observational, numerical and statistical approaches and their outcomes are reviewed. Present state of the wave-breaking research and knowledge is analysed and main outstanding problems are outlined (Authors)

  16. The Interday Measurement Consistency of and Relationships Between Hamstring and Leg Musculo-articular Stiffness.

    Science.gov (United States)

    Waxman, Justin P; Schmitz, Randy J; Shultz, Sandra J

    2015-10-01

    Hamstring stiffness (K(HAM)) and leg stiffness (K(LEG)) are commonly examined relative to athletic performance and injury risk. Given these may be modifiable, it is important to understand day-to-day variations inherent in these measures before use in training studies. In addition, the extent to which K(HAM) and K(LEG) measure similar active stiffness characteristics has not been established. We investigated the interday measurement consistency of K(HAM) and K(LEG), and examined the extent to which K(LEG) predicted K(HAM) in 6 males and 9 females. K(HAM) was moderately consistent day-to-day (ICC(2,5) = .71; SEM = 76.3 N·m(-1)), and 95% limits of agreement (95% LOA) revealed a systematic bias with considerable absolute measurement error (95% LOA = 89.6 ± 224.8 N·m(-1)). Day-to-day differences in procedural factors explained 59.4% of the variance in day-to-day differences in K(HAM). Bilateral and unilateral K(LEG) was more consistent (ICC(2,3) range = .87-.94; SEM range = 1.0-2.91 kN·m(-1)) with lower absolute error (95% LOA bilateral= -2.0 ± 10.3; left leg = -0.36 ± 3.82; right leg = -1.05 ± 3.61 kN·m(-1)). K(LEG) explained 44% of the variance in K(HAM) (P consistent and precise K(HAM) measures. The ease and consistency of K(LEG), and moderate correlation with K(HAM), may steer clinicians toward K(LEG) when measuring lower-extremity stiffness for screening studies and monitoring the effectiveness of training interventions over time.

  17. Validation of OMA formation in cold brackish and sea waters

    International Nuclear Information System (INIS)

    Khelifa, A.; Hill, P.S.

    2005-01-01

    This study addressed the challenge of cleaning oil spilled in cold, ice-infested waters in the St. Lawrence estuary in the winter. The main objective was to develop an environmentally safe and efficient cleansing method. The use of an oil-mineral agglomeration (OMA) process has been proposed to improve dispersion and biodegradation of the spilled oil. This bench-scale study was conducted to validate this proposed remedial method. The theory for this natural attenuation process for oil spills on shores is that oil droplets and suspended sediments disperse in the water column and aggregate into OMAs. OMA formation involves floc break and aggregation by differential settling. This study examined the formation time and the concentration of OMA in a typical turbulent estuarine environment and determined the effect of sediment size and concentration on OMA formation. It also verified if OMA forms in cold brackish water considering 2 types of oils which are commonly transported along the St. Lawrence estuary to Quebec City. OMA formation was validated with Heidrun and IF30 crude oils and 2 types of engineered sediments to determine the best sediment to form OMA and to determine the minimum sediment concentration needed to maximize OMA formation. The minimum agitation time to reach this maximizing condition of OMA formation was also determined. It was concluded that OMAs form readily in cold brackish and seawater when Heidrun or IF30 crude oils are mixed with chalk or bentonite sediment. 23 refs., 2 tabs., 8 figs

  18. Bubbles and breaking waves

    Science.gov (United States)

    Thorpe, S. A.

    1980-01-01

    The physical processes which control the transfer of gases between the atmosphere and oceans or lakes are poorly understood. Clouds of micro-bubbles have been detected below the surface of Loch Ness when the wind is strong enough to cause the waves to break. The rate of transfer of gas into solution from these bubbles is estimated to be significant if repeated on a global scale. We present here further evidence that the bubbles are caused by breaking waves, and discuss the relationship between the mean frequency of wave breaking at a fixed point and the average distance between breaking waves, as might be estimated from an aerial photograph.

  19. Application of flow-controllable accumulator and performance analysis in Korean Nuclear Power Plants

    International Nuclear Information System (INIS)

    Jung, Byung-Ryul; Lee, Un-Chul

    1997-01-01

    The Korean Yonggwang Nuclear Power Plants 3 ampersand 4(YGN 3 ampersand 4) are the two-loop pressurized water reactor (PWR) nuclear steam supply systems, rated at 2,815 MW(thermal). They incorporate the safety injection system (SIS) consisting of the two high pressure (HPSI) pumps, two low pressure safety injection (LPSI) pumps, and four accumulators. The SIS is two headered arrangements, each to four cold legs injection (CLI) type which provides cooling to the core in the highly unlikely event of a loss-of-coolant accident (LOCA). In the current SIS, the LPSI pumps automatically start during a LOCA, and also provide the residual heat removal capability during the shutdown cooling. This paper presents the feasibility of the removal of the LPSI from the existing SIS with minor system changes, including the increase up to four in the HPSI pumps, direct vessel injection(DVI), and the flow-controllable accumulators. A double-ended rupture of one of the four cold legs in the YGN 3 ampersand 4 was simulated using RELAP5/MOD3.1 to determine the feasibility of the application of this new SIS design to the current nuclear power plants. As a result, the calculated reflooding peak cladding surface temperature(PCT) was comparable to that of original base calculation, and the downcomer and the core collapsed liquid level during reflooding were also comparable to those in the current safety system design. This large break, cold-leg LOCA analysis addresses the reflooding capability without credit for a LPSI pump system and the applicability of the new flow-controllable accumulator. Also this analysis confirms that the combination of new flow-controllable accumulators, DVI and the increased HPSI pumps maintain the peak cladding temperature below the prescribed limits. 14 refs., 4 figs., 3 tabs

  20. Experiment data report for semiscale Mod-1 test S-01-1B (isothermal blowdown with core resistance simulator)

    International Nuclear Information System (INIS)

    Crapo, H.S.; Jensen, M.F.; Sackett, K.E.; Zender, S.N.

    1975-05-01

    Recorded test data are presented for Test S-01-1B of the semiscale Mod-1 isothermal blowdown test series. System hardware is representative of the LOFT design, selected using volumetric scaling methods, and initial conditions duplicate those identified for the LOFT nonnuclear tests. Test S-01-1B is a repeat of Test S-01-1 with the exception that simulated ECC was injected into the cold leg of the intact loop rather than into the inlet annulus of the downcomer. The principal objective of Test S-01-1B was to determine whether a different ECC injection would significantly alter the system response during the period of ECC injection. Test S-01-1B was conducted from an initial temperature of 541 0 F and an initial pressure of 1630 psig. A simulated intermediate size double-ended hot leg break (0.00145 ft 2 break area on each end) was used to investigate the system response to a slow de-pressurization transient. An orificed structure was used in the pressure vessel to simulate the LOFT core simulator. Following the blowdown portion of Test S-01-1B, coolant spray was introduced into the pressure suppression tank to determine the response of the pressure suppression system. (U.S.)

  1. ATLAS Facility and Instrumentation Description Report

    International Nuclear Information System (INIS)

    Kang, Kyoung Ho; Moon, Sang Ki; Park, Hyun Sik

    2009-06-01

    A thermal-hydraulic integral effect test facility, ATLAS (Advanced Thermal-hydraulic Test Loop for Accident Simulation), has been constructed at KAERI (Korea Atomic Energy Research Institute). The ATLAS is a half-height and 1/288-volume scaled test facility with respect to the APR1400. The fluid system of the ATLAS consists of a primary system, a secondary system, a safety injection system, a break simulating system, a containment simulating system, and auxiliary systems. The primary system includes a reactor vessel, two hot legs, four cold legs, a pressurizer, four reactor coolant pumps, and two steam generators. The secondary system of the ATLAS is simplified to be of a circulating looptype. Most of the safety injection features of the APR1400 and the OPR1000 are incorporated into the safety injection system of the ATLAS. In the ATLAS test facility, about 1300 instrumentations are installed to precisely investigate the thermal-hydraulic behavior in simulation of the various test scenarios. This report describes the scaling methodology, the geometric data of the individual component, and the specification and the location of the instrumentations which are specific to the simulation of 50% DVI line break accident of the APR1400 for supporting the 50 th OECD/NEA International Standard Problem Exercise (ISP-50)

  2. Military boot attenuates axial loading to the lower leg.

    Science.gov (United States)

    Yoganandan, Narayan; Schlick, Michael; Arun, Mike W J; Pintar, Frank A

    2014-01-01

    Biomechanical tests to understand injury mechanisms and derive injury tolerance information using Post-Mortem Human Subjects (PMHS) have not used foot protection and they have primarily focused on civilian environments such as automotive and athletic- and sports-related events. As military personnel use boots, tests with the boot are required to understand their effect on attenuating lower leg loads. The purpose of this study was therefore, to determine the modulation of human lower leg kinematics with boot compressions and share of the force absorbed by the boot from underbody blast loading. Axial impacts were delivered to the Hybrid III dummy lower leg in the neutral position. The dummy leg was instrumented with its internal upper and lower tibia load cells, and in addition, a knee load cell was attached to the proximal end. Tests were conducted at 4.4 to 8.9 m/s, with and without boots, and repeat tests were done. Morphologies of the force-time responses were similar at the three load cell locations and for all input combinations and booted and unbooted conditions. However, booted tests resulted in considerably lower maximum forces (approximately two-third reduction) than unbooted tests. These results clearly show that boots can absorb a considerable share of the impact energy and decrease impact loads transmitted to the lower leg under vertical loading, thus necessitating the generation of tolerance data using PMHS for this environment.

  3. Dynamic Leg Exercise Improves Tolerance to Lower Body Negative Pressure

    Science.gov (United States)

    Watenpaugh, D. E.; Ballard, R. E.; Stout, M. S.; Murthy, G.; Whalen, R. T.; Hargens, A. R.

    1994-01-01

    These results clearly demonstrate that dynamic leg exercise against the footward force produced by LBNP substantially improves tolerance to LBNP, and that even cyclic ankle flexion without load bearing also increases tolerance. This exercise-induced increase of tolerance was actually an underestimate, because subjects who completed the tolerance test while exercising could have continued for longer periods. Exercise probably increases LBNP tolerance by multiple mechanisms. Tolerance was increased in part by skeletal muscle pumping venous blood from the legs. Rosenhamer and Linnarsson and Rosenhamer also deduced this for subjects cycling during centrifugation, although no measurements of leg volume were made in those studies: they found that male subjects cycling at 98 W could endure 3 Gz centrifugation longer than when they remained relaxed during centrifugation. Skeletal muscle pumping helps maintain cardiac filling pressure by opposing gravity-, centrifugation-, or LBNP-induced accumulation of blood and extravascular fluid in the legs.

  4. Cold urticaria. Dissociation of cold-evoked histamine release and urticara following cold challenge.

    Science.gov (United States)

    Keahey, T M; Greaves, M W

    1980-02-01

    Nine patients with acquired cold urticaria were studied to assess the effects of beta-adrenergic agents, xanthines, and corticosteroids on cold-evoked histamine release from skin in vivo. The patients, in all of whom an immediate urticarial response developed after cooling of the forearm, demonstrated release of histamine into the venous blood draining that forearm. Following treatment with aminophylline and albuterol in combination or prednisone alone, suppression of histamine release occurred in all but one patient. In some patients, this was accompanied by a subjective diminution in pruritus or buring, but there was no significant improvement in the ensuing edema or erythema. In one patient, total suppression of histamine release was achieved without any effect on whealing and erythema in response to cold challenge. Our results suggest that histamine is not central to the pathogenesis of vascular changes in acquired cold urticaria.

  5. Experimental research on pedestrian lower leg impact

    Science.gov (United States)

    Constantin, B. A.; Iozsa, D. M.; Stan, C.

    2017-10-01

    The present paper is centred on the research of deceleration measured at the level of the lower leg during a pedestrian impact in multiple load cases. Basically, the used methodology for physical test setup is similar to EuroNCAP and European Union regulatory requirements. Due cost reduction reasons, it was not used a pneumatic system in order to launch the lower leg impactor in the direction of the vehicle front-end. During the test it was used an opposite solution, namely the vehicle being in motion, aiming the standstill lower leg impactor. The impactor has similar specifications to those at EU level, i.e. dimensions, materials, and principle of measurement of the deceleration magnitude. Therefore, all the results obtained during the study comply with the requirements of both EU regulation and EuroNCAP. As a limitation, due to unavailability of proper sensors in the equipment of the lower leg impactor, that could provide precise results, the bending angle, the shearing and the detailed data at the level of knee ligaments were not evaluated. The knee joint should be improved for future studies as some bending angles observed during the post processing of several impact video files were too high comparing to other studies. The paper highlights the first pedestrian impact physical test conducted by the author, following an extensive research in the field. Deceleration at the level of pedestrian knee can be substantially improved by providing enough volume between the bumper fascia and the front-end structure and by using pedestrian friendly materials for shock absorbers, such as foams.

  6. Toward Balance Recovery With Leg Prostheses Using Neuromuscular Model Control

    Science.gov (United States)

    Geyer, Hartmut

    2016-01-01

    Objective Lower limb amputees are at high risk of falling as current prosthetic legs provide only limited functionality for recovering balance after unexpected disturbances. For instance, the most established control method used on powered leg prostheses tracks local joint impedance functions without taking the global function of the leg in balance recovery into account. Here we explore an alternative control policy for powered transfemoral prostheses that considers the global leg function and is based on a neuromuscular model of human locomotion. Methods We adapt this model to describe and simulate an amputee walking with a powered prosthesis using the proposed control, and evaluate the gait robustness when confronted with rough ground and swing leg disturbances. We then implement and partially evaluate the resulting controller on a leg prosthesis prototype worn by a non-amputee user. Results In simulation, the proposed prosthesis control leads to gaits that are more robust than those obtained by the impedance control method. The initial hardware experiments with the prosthesis prototype show that the proposed control reproduces normal walking patterns qualitatively and effectively responds to disturbances in early and late swing. However, the response to mid-swing disturbances neither replicates human responses nor averts falls. Conclusions The neuromuscular model control is a promising alternative to existing prosthesis controls, although further research will need to improve on the initial implementation and determine how well these results transfer to amputee gait. Significance This work provides a potential avenue for future development of control policies that help improve amputee balance recovery. PMID:26315935

  7. Differences in kinematics of single leg squatting between anterior cruciate ligament-injured patients and healthy controls.

    Science.gov (United States)

    Yamazaki, J; Muneta, T; Ju, Y J; Sekiya, I

    2010-01-01

    Seventy to eighty percent of all anterior cruciate ligament (ACL) injuries are due to non-contact injury mechanisms. It has been reported that the majority of injuries due to single leg landing come from valgus positioning of the lower leg. Preventing valgus positioning during single leg landing is expected to help reduce the number of ACL injuries. We found that many ACL-deficient patients cannot perform stable single leg squatting. Therefore, we performed 3D motion analysis of the single-legged half squat for ACL-injured patients to evaluate its significance as a risk factor for ACL injuries. We evaluated the relative angles between the body, thigh, and lower leg using an electromagnetic device during single leg half squatting performed by 63 ACL-injured patients (32 males, 31 females) the day before ACL reconstruction and by 26 healthy control subjects with no knee problems. The uninjured leg of ACL-injured male subjects demonstrated significantly less external knee rotation than that of the dominant leg of the male control. The uninjured leg of ACL-injured female subjects demonstrated significantly more external hip rotation and knee flexion and less hip flexion than that of the dominant leg of the female control. Comparing injured and uninjured legs, the injured leg of male subjects demonstrated significantly less external knee and hip rotation, less knee flexion, and more knee varus than that of the uninjured leg of male subjects. The injured leg of female subjects demonstrated more knee varus than that of the uninjured leg of female subjects. Regarding gender differences, female subjects demonstrated significantly more external hip rotation and knee valgus than male subjects did in both the injured and uninjured legs (P < 0.05). The current kinematic study exhibited biomechanical characteristics of female ACL-injured subjects compared with that of control groups. Kinematic correction during single leg half squat would reduce ACL reinjury in female ACL

  8. Operation analysis of a Chebyshev-Pantograph leg mechanism for a single DOF biped robot

    Science.gov (United States)

    Liang, Conghui; Ceccarelli, Marco; Takeda, Yukio

    2012-12-01

    In this paper, operation analysis of a Chebyshev-Pantograph leg mechanism is presented for a single degree of freedom (DOF) biped robot. The proposed leg mechanism is composed of a Chebyshev four-bar linkage and a pantograph mechanism. In contrast to general fully actuated anthropomorphic leg mechanisms, the proposed leg mechanism has peculiar features like compactness, low-cost, and easy-operation. Kinematic equations of the proposed leg mechanism are formulated for a computer oriented simulation. Simulation results show the operation performance of the proposed leg mechanism with suitable characteristics. A parametric study has been carried out to evaluate the operation performance as function of design parameters. A prototype of a single DOF biped robot equipped with two proposed leg mechanisms has been built at LARM (Laboratory of Robotics and Mechatronics). Experimental test shows practical feasible walking ability of the prototype, as well as drawbacks are discussed for the mechanical design.

  9. Superconductivity in doped two-leg ladder cuprates

    International Nuclear Information System (INIS)

    Qin Jihong; Yuan Feng; Feng Shiping

    2006-01-01

    Within the t-J ladder model, superconductivity with a modified d-wave symmetry in doped two-leg ladder cuprates is investigated based on the kinetic energy driven superconducting mechanism. It is shown that the spin-liquid ground-state at the half-filling evolves into the superconducting ground-state upon doping. In analogy to the doping dependence of the superconducting transition temperature in the planar cuprate superconductors, the superconducting transition temperature in doped two-leg ladder cuprates increases with increasing doping in the underdoped regime, and reaches a maximum in the optimal doping, then decreases in the overdoped regime

  10. Two-legged walking robot prescribed motion on a rough cylinder

    Science.gov (United States)

    Golubev, Yury; Melkumova, Elena

    2018-05-01

    The motion of a walking robot with n legs, that ensure the desired motion of the robot body, is described using general dynamics theoretical framework. When each of the robot legs contacts the surface in a single foothold, the momentum and angular momentum theorems yield a system of six differential equations that form a complete description of the robot motion. In the case of two-leg robot (n = 2) the problem of the existence of the solution can be reduced to a system of algebraic inequalities. Using numerical analysis, the classification of footholds positions for different values of the friction coefficient is obtained.

  11. STRUCTURE OF PROMINENCE LEGS: PLASMA AND MAGNETIC FIELD

    Energy Technology Data Exchange (ETDEWEB)

    Levens, P. J.; Labrosse, N. [SUPA School of Physics and Astronomy, University of Glasgow, Glasgow, G12 8QQ (United Kingdom); Schmieder, B. [Observatoire de Paris, Meudon, F-92195 (France); Ariste, A. López, E-mail: p.levens.1@research.gla.ac.uk [Institut de Recherche en Astrophysique et Planétologie, Toulouse (France)

    2016-02-10

    We investigate the properties of a “solar tornado” observed on 2014 July 15, and aim to link the behavior of the plasma to the internal magnetic field structure of the associated prominence. We made multi-wavelength observations with high spatial resolution and high cadence using SDO/AIA, the Interface Region Imaging Spectrograph (IRIS) spectrograph, and the Hinode/Solar Optical Telescope (SOT) instrument. Along with spectropolarimetry provided by the Télescope Héliographique pour l’Etude du Magnétisme et des Instabilités Solaires telescope we have coverage of both optically thick emission lines and magnetic field information. AIA reveals that the two legs of the prominence are strongly absorbing structures which look like they are rotating, or oscillating in the plane of the sky. The two prominence legs, which are both very bright in Ca ii (SOT), are not visible in the IRIS Mg ii slit-jaw images. This is explained by the large optical thickness of the structures in Mg ii, which leads to reversed profiles, and hence to lower integrated intensities at these locations than in the surroundings. Using lines formed at temperatures lower than 1 MK, we measure relatively low Doppler shifts on the order of ±10 km s{sup −1} in the tornado-like structure. Between the two legs we see loops in Mg ii, with material flowing from one leg to the other, as well as counterstreaming. It is difficult to interpret our data as showing two rotating, vertical structures that are unrelated to the loops. This kind of “tornado” scenario does not fit with our observations. The magnetic field in the two legs of the prominence is found to be preferentially horizontal.

  12. RSRM Nozzle-to-Case Joint J-leg Development

    Science.gov (United States)

    Albrechtsen, Kevin U.; Eddy, Norman F.; Ewing, Mark E.; McGuire, John R.

    2003-01-01

    Since the beginning of the Space Shuttle Reusable Solid Rocket Motor (RSRM) program, nozzle-to-case joint polysulfide adhesive gas paths have occurred on several flight motors. These gas paths have allowed hot motor gases to reach the wiper O-ring. Even though these motors continue to fly safely with this condition, a desire was to reduce such occurrences. The RSRM currently uses a J-leg joint configuration on case field joints and igniter inner and outer joints. The J-leg joint configuration has been successfully demonstrated on numerous RSRM flight and static test motors, eliminating hot gas intrusion to the critical O-ring seals on these joints. Using the proven technology demonstrated on the case field joints and igniter joints, a nozzle-to-case joint J-leg design was developed for implementation on RSRM flight motors. This configuration provides an interference fit with nozzle fixed housing phenolics at assembly, with a series of pressurization gaps incorporated outboard of the joint mating surface to aid in joint pressurization and to eliminate any circumferential flow in this region. The joint insulation is bonded to the nozzle phenolics using the same pressure sensitive adhesive used in the case field joints and igniter joints. An enhancement to the nozzle-to-case joint J-leg configuration is the implementation of a carbon rope thermal barrier. The thermal barrier is located downstream of the joint bondline and is positioned within the joint in a manner where any hot gas intrusion into the joint passes through the thermal barrier, reducing gas temperatures to a level that would not affect O-rings downstream of the thermal barrier. This paper discusses the processes used in reaching a final nozzle-to-case joint J-leg design, provides structural and thermal results in support of the design, and identifies fabrication techniques and demonstrations used in arriving at the final configuration.

  13. Restless Legs Syndrome in a Nigerian Elderly Population

    Science.gov (United States)

    Fawale, Michael B.; Ismaila, Isiaka Alani; Mustapha, Adekunle F.; Komolafe, Morenikeji A.; Adedeji, Tewogbade A.

    2016-01-01

    Study Objectives: The prevalence of restless legs syndrome (RLS) is highest in the elderly in Caucasian populations; the prevalence of RLS in elderly Africans is not known. This study aimed at determining the frequency and associations of RLS in a Nigerian elderly population. Methods: The study population comprised of 633 consecutive elderly individuals aged 65–105 years attending the general outpatient clinic of the State Hospital, Ilesa, for minor complaints and routine check-up. The diagnosis of RLS was made using the 2003 minimal criteria of the International Restless Legs Syndrome Study Group. Relevant sociodemographic and clinical data, including sleep duration, were also obtained. Results: Restless legs syndrome was found in 3.5% of the study population with a male-female ratio of 2:1. There was no significant age (p = 0.427) or gender (p = 0.178) influence on the prevalence of RLS except in the 75- to 84-year age group where there was significant male preponderance (p = 0.044). A strong independent association between RLS and sleep duration (OR, 3.229; 95% CI, 1.283–8.486; p = 0.013) and past history of head injury (OR, 4.691; 95% CI, 1.750–12.577; p = 0.002) was found. Conclusions: Our finding support previous reports of a possible lower prevalence of RLS in Africans. Restless legs syndrome independently increases the odds of habitual sleep curtailment in elderly individuals. Head injury may be a risk factor for future RLS; this requires further investigation as indirect evidence for a possible link between RLS and traumatic brain injury exists. Citation: Fawale MB, Ismaila IA, Mustapha AF, Komolafe MA, Adedeji TA. Restless legs syndrome in a Nigerian elderly population. J Clin Sleep Med 2016;12(7):965–972. PMID:27070251

  14. Bioinspired legged-robot based on large deformation of flexible skeleton

    International Nuclear Information System (INIS)

    Mayyas, Mohammad

    2014-01-01

    In this article we present STARbot, a bioinspired legged robot capable of multiple locomotion modalities by using large deformation of its skeleton. We construct STARbot by using origami-style folding of flexible laminates. The long-term goal is to provide a robotic platform with maximum mobility on multiple surfaces. This paper particularly studies the quasistatic model of STARbot’s leg under different conditions. We describe the large elastic deformation of a leg under external force, payload, and friction by using a set of non-dimensional, nonlinear approximate equations. We developed a test mechanism that models the motion of a leg in STARbot. We augmented several foot shapes and then tested them on soft to rough grounds. Both simulation and experimental findings were in good agreement. We utilized the model to develop several scales of tri and quad STARbot. We demonstrated the capability of these robots to locomote by combining their leg deformations with their foot motions. The combination provided a design platform for an active suspension STARbot with controlled foot locomotion. This included the ability of STARbot to change size, run over obstacles, walk and slide. Furthermore, in this paper we discuss a cost effective manufacturing and production method for manufacturing STARbot. (paper)

  15. Bioinspired legged-robot based on large deformation of flexible skeleton.

    Science.gov (United States)

    Mayyas, Mohammad

    2014-11-11

    In this article we present STARbot, a bioinspired legged robot capable of multiple locomotion modalities by using large deformation of its skeleton. We construct STARbot by using origami-style folding of flexible laminates. The long-term goal is to provide a robotic platform with maximum mobility on multiple surfaces. This paper particularly studies the quasistatic model of STARbot's leg under different conditions. We describe the large elastic deformation of a leg under external force, payload, and friction by using a set of non-dimensional, nonlinear approximate equations. We developed a test mechanism that models the motion of a leg in STARbot. We augmented several foot shapes and then tested them on soft to rough grounds. Both simulation and experimental findings were in good agreement. We utilized the model to develop several scales of tri and quad STARbot. We demonstrated the capability of these robots to locomote by combining their leg deformations with their foot motions. The combination provided a design platform for an active suspension STARbot with controlled foot locomotion. This included the ability of STARbot to change size, run over obstacles, walk and slide. Furthermore, in this paper we discuss a cost effective manufacturing and production method for manufacturing STARbot.

  16. Experiment data report for Semiscale Mod-1 test S-02-5 (blowdown heat transfer test)

    International Nuclear Information System (INIS)

    1975-12-01

    Recorded test data are presented for Test S-02-5 of the Semiscale Mod-1 blowdown heat transfer test series. Test S-02-5 is one of several Semiscale Mod-1 experiments conducted to investigate the thermal and hydraulic phenomena accompanying a hypothesized loss-of-coolant accident in a water-cooled nuclear reactor system and to provide data for the assessment of the Loss-of-Fluid Test (LOFT) design basis. Test S-02-5 was conducted from an initial cold leg fluid temperature of 544 0 F and an initial pressure of 2,253 psia. A simulated double-ended offset shear cold leg break was used to investigate the system response to a depressurization transient with full core power (1.6 MW). An electrically heated core was used in the pressure vessel to simulate the effects of a nuclear core. System flow was set to achieve the full design core temperature differential of 66 0 F. The flow resistance of the intact loop was based on core area scaling. During system depressurization, core power was reduced from the initial level of 1.6 MW in such a manner as to simulate the surface heat flux response of the LOFT nuclear fuel rods until such time that departure from nucleate boiling occurs

  17. Research on the improvement of nuclear safety -The development of LOCA analysis codes for nuclear power plant-

    Energy Technology Data Exchange (ETDEWEB)

    Jang, Won Pyo; Jung, Yung Jong; Kim, Kyung Doo; Jung, Jae Joon; Kim, Won Suk; Han, Doh Heui; Hah, Kooi Suk; Jung, Bub Dong; Lee, Yung Jin; Hwang, Tae Suk; Lee, Sang Yong; Park, Chan Uk; Choi, Han Rim; Lee, Sang Jong; Choi, Jong Hoh; Ban, Chang Hwan; Bae, Kyoo Hwan [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of)

    1995-07-01

    The present research aims at development of both a best estimate methodology on LOCA analysis and, as an application, performance analyses of safety systems. SBLOCA analyses have been continued to examine the capacity reduction effect of ECCS since the second project year. As a results, core uncovery, which is requirement of URD has not been occurred in 6`` cold leg break. Although core uncovery has been predicted when DVI line has been broken for DVI+4-Train HPIS, the calculated PCT has lied well within the criterion. The effect of safety injection position and SIT characteristics are also analyzed for LBLOCA. The results show that cold leg injection is the most effective way and the adaption of advanced SIT could lead to elimination of LPSI pump from the safety system. On the other hand, the quantified uncertainties obtained from THTF and FLECHT/SEASET which represents blowdown and reflood phenomena, respectively, have been confirmed using IET(LOFT test). The application uncertainty for Kori unit 3 has been analyzed. Finally, application of the best estimate methodology using the uncertainties concerned with the code, the bais, and the application, leads to overall uncertainty of about 200K for Kori unit 3. 244 figs, 22 tabs, 92 refs. (Author).

  18. Research on the improvement of nuclear safety -The development of LOCA analysis codes for nuclear power plant-

    International Nuclear Information System (INIS)

    Jang, Won Pyo; Jung, Yung Jong; Kim, Kyung Doo; Jung, Jae Joon; Kim, Won Suk; Han, Doh Heui; Hah, Kooi Suk; Jung, Bub Dong; Lee, Yung Jin; Hwang, Tae Suk; Lee, Sang Yong; Park, Chan Uk; Choi, Han Rim; Lee, Sang Jong; Choi, Jong Hoh; Ban, Chang Hwan; Bae, Kyoo Hwan

    1995-07-01

    The present research aims at development of both a best estimate methodology on LOCA analysis and, as an application, performance analyses of safety systems. SBLOCA analyses have been continued to examine the capacity reduction effect of ECCS since the second project year. As a results, core uncovery, which is requirement of URD has not been occurred in 6'' cold leg break. Although core uncovery has been predicted when DVI line has been broken for DVI+4-Train HPIS, the calculated PCT has lied well within the criterion. The effect of safety injection position and SIT characteristics are also analyzed for LBLOCA. The results show that cold leg injection is the most effective way and the adaption of advanced SIT could lead to elimination of LPSI pump from the safety system. On the other hand, the quantified uncertainties obtained from THTF and FLECHT/SEASET which represents blowdown and reflood phenomena, respectively, have been confirmed using IET(LOFT test). The application uncertainty for Kori unit 3 has been analyzed. Finally, application of the best estimate methodology using the uncertainties concerned with the code, the bais, and the application, leads to overall uncertainty of about 200K for Kori unit 3. 244 figs, 22 tabs, 92 refs. (Author)

  19. Analysis of ATLAS LTC-04R Test for Loop Seal Reformation Phenomena using RELAP5

    Energy Technology Data Exchange (ETDEWEB)

    Lim, Sang-Gyu; Kim, Dae-Hun; Kim, Han-Gon [KHNP CRI, Daejeon (Korea, Republic of)

    2016-10-15

    The loop seal reformation issue was selected to be the analysis topic of the DSP-04 based on the technical discussion between the participants and the operating agencies (KAERI and KINS) and domestic experts meetings. After that, KAERI performed LTC-04R test which is 4 inch top-slot cold-leg break test using ATLAS facility in December 27, 2015. KHNP CRI, as a participant of the DSP-04, performed the blind calculation and open calculation using RELAP5/Mod3.3 patch 3. This paper deals with the results of open calculation for ATLAS LTC-04R test. The results of several sensitivity analyses such as the critical flow modeling sensitivity and break flow system modeling sensitivity will be discussed. Several possible factors in the loop seal reformation behavior are examined in the sensitivity analysis. Heat loss modeling, fine break system modeling, fine loop seal nodalization and off-take modeling are not significant factor in the loop seal reformation. Still critical flow model and discharge coefficient are dominant factors. Based on the ATLAS LTC-04R, Ransom-Trapp model shows better prediction in the break flow than the Henry-Fauske model.

  20. A model of intrinsic symmetry breaking

    International Nuclear Information System (INIS)

    Ge, Li; Li, Sheng; George, Thomas F.; Sun, Xin

    2013-01-01

    Different from the symmetry breaking associated with a phase transition, which occurs when the controlling parameter is manipulated across a critical point, the symmetry breaking presented in this Letter does not need parameter manipulation. Instead, the system itself suddenly undergoes symmetry breaking at a certain time during its evolution, which is intrinsic symmetry breaking. Through a polymer model, it is revealed that the origin of the intrinsic symmetry breaking is nonlinearity, which produces instability at the instance when the evolution crosses an inflexion point, where this instability breaks the original symmetry

  1. Relationships of self-identified cold tolerance and cold-induced vasodilatation in the finger

    Science.gov (United States)

    Park, Joonhee; Lee, Joo-Young

    2016-04-01

    This study was conducted to investigate relationships of self-identified cold tolerance and cold-induced vasodilatation (CIVD) in the finger. Nine males and 34 females participated in the following 2 tests: a CIVD test and a self-reported survey. The CIVD test was conducted 30-min cold-water immersion (3.8 ± 0.3 °C) of the middle finger at an air temperature of 27.9 ± 0.1 °C. The self-reported questionnaire consisted of 28 questions about whole and local body cold and heat tolerances. By a cluster analysis on the survey results, the participants were divided into two groups: high self-identified cold tolerance (HSCT, n = 25) and low self-identified cold tolerance (LSCT, n = 18). LSCT had lower self-identified cold tolerance ( P cold or heat tolerance had relationships with cold tolerance index, T max, and amplitude ( P cold tolerance classified through a standardized survey could be a good index to predict physiological cold tolerance.

  2. Quality of Life in People with Leg Ulcer, Integrative Review

    Directory of Open Access Journals (Sweden)

    Daniela Alves

    2016-04-01

    Full Text Available Objective: To identify the main changes in the daily life of people with leg ulcer and how that affects the person’s quality of life. Methodology: We used the methodology PI [C] OD and selected four research articles, taken from EBSCO, PubMed, and EWMA. Results: The main changes identified in the people’s daily live with leg ulcers are physical (pain, decreased mobility, presence of exudate, bad smell from the wound and change in the style of clothing, psychological (sleep disorders, depression, anxiety, feelings of rejection and low self-steem, social (isolation, restriction in leisure activities, inability to perform household chores. Conclusions: The literature about the person’s quality of life with leg ulcer reported a significant impact in the daily life. The care provided by nurses should be centered on the person, integrating all the kind of needs and the leg ulcer must not be the sole focus of care

  3. Simulation of breaking waves using the high-order spectral method with laboratory experiments: Wave-breaking onset

    Science.gov (United States)

    Seiffert, Betsy R.; Ducrozet, Guillaume; Bonnefoy, Félicien

    2017-11-01

    This study investigates a wave-breaking onset criteria to be implemented in the non-linear potential flow solver HOS-NWT. The model is a computationally efficient, open source code, which solves for the free surface in a numerical wave tank using the High-Order Spectral (HOS) method. The goal of this study is to determine the best method to identify the onset of random single and multiple breaking waves over a large domain at the exact time they occur. To identify breaking waves, a breaking onset criteria based on the ratio of local energy flux velocity to the local crest velocity, introduced by Barthelemy et al. (2017) is selected. The breaking parameter is uniquely applied in the numerical model in that calculations of the breaking onset criteria ratio are not made only at the location of the wave crest, but at every point in the domain and at every time step. This allows the model to calculate the onset of a breaking wave the moment it happens, and without knowing anything about the wave a priori. The application of the breaking criteria at every point in the domain and at every time step requires the phase velocity to be calculated instantaneously everywhere in the domain and at every time step. This is achieved by calculating the instantaneous phase velocity using the Hilbert transform and dispersion relation. A comparison between more traditional crest-tracking techniques shows the calculation of phase velocity using Hilbert transform at the location of the breaking wave crest provides a good approximation of crest velocity. The ability of the selected wave breaking criteria to predict single and multiple breaking events in two dimensions is validated by a series of large-scale experiments. Breaking waves are generated by energy focusing and modulational instability methods, with a wide range of primary frequencies. Steep irregular waves which lead to breaking waves, and irregular waves with an energy focusing wave superimposed are also generated. This set of

  4. Leg stiffness during phases of countermovement and take-off in vertical jump.

    Science.gov (United States)

    Struzik, Artur; Zawadzki, Jerzy

    2013-01-01

    With respect to cyclic movements such as human gait, running or hopping, leg stiffness is a little variable parameter. The aim of this study was to investigate changes in leg stiffness during the phase of countermovement and take-off when performing a single maximum counter-movement jump. Kistler force plates and a BTS SMART system for comprehensive motion analysis were employed in the study. The study covered a group of 12 athletes from university basketball teams. Leg stiffness was calculated in those parts of countermovement and take-off phases where its level is relatively constant and the relationship F(Δl) is similar to linear one. Mean total stiffness (±SD) in both legs in the countermovement phase amounted to 6.5 ± 1.5 kN/m, whereas during the take-off phase this value was 6.9 ± 1 kN/m. No statistically significant differences were found between leg stiffness during the countermovement phase and takeoff phase in the study group at the level of significance set at α = 0.05. This suggests that the leg stiffness in phase of countermovement and phase of take-off are much similar to each other, despite different function of both phases. Similar to cyclic movements, leg stiffness turned out relatively constant when performing a single vertical jump. There are also reported statistically significant correlations between body mass, body height, length of lower limbs and leg stiffness. The stiffness analysed by the authors should be understood as quasi-stiffness because the measurements of ΔF(Δl) were made during transient states where inertia and dumping forces are likely to affect the final result.

  5. A study on the temperature distribution in the hot leg pipe

    International Nuclear Information System (INIS)

    Choe, Yoon-Jae; Baik, Se-Jin; Jang, Ho-Cheol; Lee, Byung-Jin; Im, In-Young; Ro, Tae-Sun

    2003-01-01

    In the hot leg pipes of reactor coolant system of the Korean Standard Nuclear Power Plant (KSNP), a non-uniform distribution in temperature has been observed across the cross-section, which is attributed to the non-uniformity of power distribution in the reactor core usually having a peak in the center region, and to the colder coolant bypass flow through the reactor vessel outlet nozzle clearances. As a result, the arithmetic mean temperature of four Resistance Temperature Detectors (RTDs) installed in each hot leg - two in the upper region and two in the lower region around the pipe wall may not correctly represent the actual coolant bulk temperature. It is also believed that there is a skewness in the velocity profile in the hot leg pipe due to the sudden changes in the flow direction and area from the core to the hot leg pipe, through the reactor vessel outlet plenum. These temperature non-uniformity and velocity skewness affect the measurement of the plant parameter such as the reactor coolant flow rate which is calculated by using the bulk temperature of hot leg pipes. A computational analysis has been performed to simulate the temperature and velocity distributions and to evaluate the uncertainty of temperature correction offset in the hot leg pipe. A commercial CFD code, FLUENT, is used for this analysis. The analysis results are compared with the operational data of KSNP and the scaled-down model test data for System 80. From the comparisons, an uncertainty of correction offset is obtained to measure the bulk temperature of hot leg more accurately, which can be also applied to the operating plants, leading to the reduction of temperature measurement uncertainty. Since the uncertainty of temperature in the hot leg pipe is one of major parameters to calculate the uncertainty of the reactor coolant flow rate, the analysis results can contribute to the improvement of the plant performance and safety by reducing the uncertainty of temperature measurement

  6. A tracked robot with novel bio-inspired passive "legs".

    Science.gov (United States)

    Sun, Bo; Jing, Xingjian

    2017-01-01

    For track-based robots, an important aspect is the suppression design, which determines the trafficability and comfort of the whole system. The trafficability limits the robot's working capability, and the riding comfort limits the robot's working effectiveness, especially with some sensitive instruments mounted on or operated. To these aims, a track-based robot equipped with a novel passive bio-inspired suspension is designed and studied systematically in this paper. Animal or insects have very special leg or limb structures which are good for motion control and adaptable to different environments. Inspired by this, a new track-based robot is designed with novel "legs" for connecting the loading wheels to the robot body. Each leg is designed with passive structures and can achieve very high loading capacity but low dynamic stiffness such that the robot can move on rough ground similar to a multi-leg animal or insect. Therefore, the trafficability and riding comfort can be significantly improved without losing loading capacity. The new track-based robot can be well applied to various engineering tasks for providing a stable moving platform of high mobility, better trafficability and excellent loading capacity.

  7. Effects of leg dominance on performance of ballet turns (pirouettes) by experienced and novice dancers.

    Science.gov (United States)

    Lin, Chia-Wei; Su, Fong-Chin; Wu, Hong-Wen; Lin, Cheng-Feng

    2013-01-01

    Turns (pirouettes) are an important movement in ballet and may be affected by "lateral bias". This study investigated physiological differences exhibited by experienced and novice dancers, respectively, when performing pirouette with dominant and non-dominant leg supports, respectively. Thirteen novice and 13 experienced dancers performed turns on dominant or non-dominant legs. The maximum ankle plantarflexion, knee extension and hip extension were measured during the single-leg support phase. The inclination angle of rotation axis is the angle between instantaneous rotation axis and global vertical axis in the early single-leg support phase. Both groups exhibited a greater hip extension, knee extension, and ankle plantarflexion when performing a turn on the non-dominant leg. For experienced dancers, the inclination angle of rotation axis during the pre-swing phase was generally smaller for dominant leg support than non-dominant leg. However, no significant difference was found in inclination angle of rotation axis of novice dancers. For experienced dancers, an improved performance is obtained when using the dominant leg for support. By contrast, for novice dancers, the performance is independent of choice of support leg. The significant lateral bias in experienced dancers indicates the possible influence of training. That is, repetitive rehearsal on the preferred leg strengthens the impact of side dominance in experienced dancers.

  8. How to determine leg dominance: The agreement between self-reported and observed performance in healthy adults.

    Directory of Open Access Journals (Sweden)

    Nicky van Melick

    Full Text Available Since decades leg dominance is suggested to be important in rehabilitation and return to play in athletes with anterior cruciate ligament injuries. However, an ideal method to determine leg dominance in relation to task performance is still lacking.To test the agreement between self-reported and observed leg dominance in bilateral mobilizing and unilateral stabilizing tasks, and to assess whether the dominant leg switches between bilateral mobilizing tasks and unilateral stabilizing tasks.Cross-sectional study.Forty-one healthy adults: 21 men aged 36 ± 17 years old and 20 women aged 36 ±15 years old.Participants self-reported leg dominance in the Waterloo Footedness Questionnaire-Revised (WFQ-R, and leg dominance was observed during performance of four bilateral mobilizing tasks and two unilateral stabilizing tasks. Descriptive statistics and crosstabs were used to report the percentages of agreement.The leg used to kick a ball had 100% agreement between the self-reported and observed dominant leg for both men and women. The dominant leg in kicking a ball and standing on one leg was the same in 66.7% of the men and 85.0% of the women. The agreement with jumping with one leg was lower: 47.6% for men and 70.0% for women.It is appropriate to ask healthy adults: "If you would shoot a ball on a target, which leg would you use to shoot the ball?" to determine leg dominance in bilateral mobilizing tasks. However, a considerable number of the participants switched the dominant leg in a unilateral stabilizing task.

  9. Consequences in the pumps operation during a large loss of coolant accident

    International Nuclear Information System (INIS)

    Santos, G.A. dos; Sabundjian, G.

    1991-08-01

    The event of living on or turning off the operation of the Reactor Cooling Pumps - RCPs, in the case of a Loss of Coolant Accident - LOCA, has been a reason of a lot of studies after the Three Mile Island 2 accident. Thus, it was investigated a large break LOCA in the cold leg of Angra 1, with the RELAP4/MOD5 Code during the blowdown. The attained results indicated that the best performance of the core was in the case where the RCPs had been turned off in the beginning of the transient, when compared with different operation conditions of the RCPs. (author)

  10. A PWR reactor downcomer modification for reduction of ECC bypass flow during LOCA

    International Nuclear Information System (INIS)

    Popov, N.; Bosevski, T.

    1986-01-01

    The ECC bypass phenomenon in the PWR reactor down-comer, which delays the reactor vessel refilling, after cold leg large break LOCA accident, has been subject of analysis in this paper. In the paper, a particular construction modification of the reactor down-comer has been suggested by inserting vertical ribs, aimed to intensify the reactor ECC refilling following the LOCA accident, and to advance the thermal-hydraulics safety of post-accidental cooling of the PWR reactors. To verify the effectiveness of the suggested down-comer construction modification, some properly selected results, obtained by corresponding verified mathematical model, have been presented in this paper. (author)

  11. Comparison between Unilateral and Bilateral Plyometric Training on Single and Double Leg Jumping Performance and Strength.

    Science.gov (United States)

    Bogdanis, Gregory C; Tsoukos, Athanasios; Kaloheri, Olga; Terzis, Gerasimos; Veligekas, Panagiotis; Brown, Lee E

    2017-04-18

    This study compared the effects of unilateral and bilateral plyometric training on single and double-leg jumping performance, maximal strength and rate of force development (RFD). Fifteen moderately trained subjects were randomly assigned to either a unilateral (U, n=7) or bilateral group (B, n=8). Both groups performed maximal effort plyometric leg exercises two times per week for 6 weeks. The B group performed all exercises with both legs, while the U group performed half the repetitions with each leg, so that total exercise volume was the same. Jumping performance was assessed by countermovement jumps (CMJ) and drop jumps (DJ), while maximal isometric leg press strength and RFD were measured before and after training for each leg separately and both legs together. CMJ improvement with both legs was not significantly different between U (12.1±7.2%) and B (11.0±5.5%) groups. However, the sum of right and left leg CMJ only improved in the U group (19.0±7.1%, pplyometric training was more effective at increasing both single and double-leg jumping performance, isometric leg press maximal force and RFD when compared to bilateral training.

  12. H:q ratios and bilateral leg strength in college field and court sports players.

    Science.gov (United States)

    Cheung, Roy T H; Smith, Andrew W; Wong, Del P

    2012-06-01

    One of the key components in sports injury prevention is the identification of imbalances in leg muscle strength. However, different leg muscle characteristics may occur in large playing area (field) sports and small playing area (court) sports, which should be considered in regular injury prevention assessment. This study examined the isokinetic hamstrings-to-quadriceps (H:Q) ratio and bilateral leg strength balance in 40 male college (age: 23.4 ± 2.5 yrs) team sport players (field sport = 23, soccer players; court sport = 17, volleyball and basketball players). Five repetitions of maximal knee concentric flexion and concentric extension were performed on an isokinetic dynamometer at two speeds (slow: 60°·s(-1) and fast: 300°·s(-1)) with 3 minutes rest between tests. Both legs were measured in counterbalanced order with the dominant leg being determined as the leg used to kick a ball. The highest concentric peak torque values (Nm) of the hamstrings and quadriceps of each leg were analyzed after body mass normalization (Nm·kg(-1)). Court sport players showed significantly weaker dominant leg hamstrings muscles at both contraction speeds (P Sport-specific leg muscle strength was evident in college players from field and court sports. These results suggest the need for different muscle strength training and rehabilitation protocols for college players according to the musculature requirements in their respective sports.

  13. Development of the MARS input model for Ulchin 1/2 transient analyzer

    International Nuclear Information System (INIS)

    Jeong, J. J.; Kim, K. D.; Lee, S. W.; Lee, Y. J.; Chung, B. D.; Hwang, M.

    2003-03-01

    KAERI has been developing the NSSS transient analyzer based on best-estimate codes for Ulchin 1/2 plants. The MARS and RETRAN code are used as the best-estimate codes for the NSSS transient analyzer. Among the two codes, the MARS code is to be used for realistic analysis of small- and large-break loss-of-coolant accidents, of which break size is greater than 2 inch diameter. This report includes the input model requirements and the calculation note for the Ulchin 1/2 MARS input data generation (see the Appendix). In order to confirm the validity of the input data, we performed the calculations for a steady state at 100 % power operation condition and a double-ended cold leg break LOCA. The results of the steady-state calculation agree well with the design data. The results of the LOCA calculation seem to be reasonable and consistent with those of other best-estimate calculations. Therefore, the MARS input data can be used as a base input deck for the MARS transient analyzer for Ulchin 1/2

  14. Development of the MARS input model for Ulchin 3/4 transient analyzer

    International Nuclear Information System (INIS)

    Jeong, J. J.; Kim, K. D.; Lee, S. W.; Lee, Y. J.; Lee, W. J.; Chung, B. D.; Hwang, M. G.

    2003-12-01

    KAERI has been developing the NSSS transient analyzer based on best-estimate codes.The MARS and RETRAN code are adopted as the best-estimate codes for the NSSS transient analyzer. Among these two codes, the MARS code is to be used for realistic analysis of small- and large-break loss-of-coolant accidents, of which break size is greater than 2 inch diameter. This report includes the MARS input model requirements and the calculation note for the MARS input data generation (see the Appendix) for Ulchin 3/4 plant analyzer. In order to confirm the validity of the input data, we performed the calculations for a steady state at 100 % power operation condition and a double-ended cold leg break LOCA. The results of the steady-state calculation agree well with the design data. The results of the LOCA calculation seem to be reasonable and consistent with those of other best-estimate calculations. Therefore, the MARS input data can be used as a base input deck for the MARS transient analyzer for Ulchin 3/4

  15. Indian Point 2 steam generator tube rupture analyses

    International Nuclear Information System (INIS)

    Dayan, A.

    1985-01-01

    Analyses were conducted with RETRAN-02 to study consequences of steam generator tube rupture (SGTR) events. The Indian Point, Unit 2, power plant (IP2, PWR) was modeled as a two asymmetric loops, consisting of 27 volumes and 37 junctions. The break section was modeled once, conservatively, as a 150% flow area opening at the wall of the steam generator cold leg plenum, and once as a 200% double-ended tube break. Results revealed 60% overprediction of breakflow rates by the traditional conservative model. Two SGTR transients were studied, one with low-pressure reactor trip and one with an earlier reactor trip via over temperature ΔT. The former is more typical to a plant with low reactor average temperature such as IP2. Transient analyses for a single tube break event over 500 seconds indicated continued primary subcooling and no need for steam line pressure relief. In addition, SGTR transients with reactor trip while the pressurizer still contains water were found to favorably reduce depressurization rates. Comparison of the conservative results with independent LOFTRAN predictions showed good agreement

  16. Asymmetry between the Dominant and Non-Dominant Legs in the Kinematics of the Lower Extremities during a Running Single Leg Jump in Collegiate Basketball Players.

    Science.gov (United States)

    Sugiyama, Takashi; Kameda, Mai; Kageyama, Masahiro; Kiba, Kazufusa; Kanehisa, Hiroaki; Maeda, Akira

    2014-12-01

    The present study aimed to clarify the asymmetry between the dominant (DL) and non-dominant takeoff legs (NDL) in terms of lower limb behavior during running single leg jumps (RSJ) in collegiate male basketball players in relation to that of the jump height. Twenty-seven players performed maximal RSJ with a 6 m approach. Three-dimensional kinematics data during RSJ was collected using a 12 Raptor camera infrared motion analysis system (MAC 3D system) at a sampling frequency of 500 Hz. The symmetry index in the jump heights and the kinematics variables were calculated as {2 × (DL - NDL) / (DL + NDL)} × 100. The run-up velocity was similar between the two legs, but the jump height was significantly higher in the DL than in the NDL. During the takeoff phase, the joint angles of the ankle and knee were significantly larger in the DL than the NDL. In addition, the contact time for the DL was significantly shorter than that for the NDL. The symmetry index of the kinematics for the ankle joint was positively correlated with that of jump height, but that for the knee joint was not. The current results indicate that, for collegiate basketball players, the asymmetry in the height of a RSJ can be attributed to that in the joint kinematics of the ankle during the takeoff phase, which may be associated with the ability to effectively transmit run-up velocity to jump height. Key pointsAsymmetry of height during running single leg jump between two legs is due to the behavior of the ankle joint (i.e. stiffer the ankle joint and explosive bounding).The dominant leg can transmit run-up velocity into the vertical velocity at takeoff phase to jump high compared with the non-dominant leg.Basketball players who have a greater asymmetry of the RSJ at the collegiate level could be assessed as non-regulars judging by the magnitude of asymmetry.

  17. Flux rope breaking and formation of a rotating blowout jet

    Science.gov (United States)

    Joshi, Navin Chandra; Nishizuka, Naoto; Filippov, Boris; Magara, Tetsuya; Tlatov, Andrey G.

    2018-05-01

    We analysed a small flux rope eruption converted into a helical blowout jet in a fan-spine configuration using multiwavelength observations taken by Solar Dynamics Observatory, which occurred near the limb on 2016 January 9. In our study, first, we estimated the fan-spine magnetic configuration with the potential-field calculation and found a sinistral small filament inside it. The filament along with the flux rope erupted upwards and interacted with the surrounding fan-spine magnetic configuration, where the flux rope breaks in the middle section. We observed compact brightening, flare ribbons, and post-flare loops underneath the erupting filament. The northern section of the flux rope reconnected with the surrounding positive polarity, while the southern section straightened. Next, we observed the untwisting motion of the southern leg, which was transformed into a rotating helical blowout jet. The sign of the helicity of the mini-filament matches the one of the rotating jets. This is consistent with recent jet models presented by Adams et al. and Sterling et al. We focused on the fine thread structure of the rotating jet and traced three blobs with the speed of 60-120 km s- 1, while the radial speed of the jet is ˜400 km s- 1. The untwisting motion of the jet accelerated plasma upwards along the collimated outer spine field lines, and it finally evolved into a narrow coronal mass ejection at the height of ˜9Rsun. On the basis of detailed analysis, we discussed clear evidence of the scenario of the breaking of the flux rope and the formation of the helical blowout jet in the fan-spine magnetic configuration.

  18. Genetic correlations between claw health and feet and leg conformation in Norwegian Red cows.

    Science.gov (United States)

    Ødegård, C; Svendsen, M; Heringstad, B

    2014-07-01

    The aim of this study was to estimate genetic correlations between claw disorders and feet and leg conformation traits in Norwegian Red cows. A total of 188,928 cows with claw health status recorded at claw trimming from 2004 to September 2013 and 210,789 first-lactation cows with feet and leg conformation scores from 2001 to September 2013 were included in the analyses. Traits describing claw health were corkscrew claw, infectious claw disorders (dermatitis, heel horn erosion, and interdigital phlegmon), and laminitis-related claw disorders (sole ulcer, white line disorder, and hemorrhage of sole and white line). The feet and leg conformation traits were rear leg rear view (new and old definition), rear leg side view, foot angle, and hoof quality. Feet and leg conformation traits were scored linearly from 1 to 9, with optimum scores depending on the trait. Claw disorders were defined as binary (0/1) traits for each lactation. Threshold sire models were used to model claw disorders, whereas the feet and leg conformation traits were described by linear sire models. Three multivariate analyses were performed, each including the 5 feet and leg conformation traits and 1 of the 3 claw disorders at a time. Posterior means of heritability of liability of claw disorders ranged from 0.10 to 0.20 and heritabilities of feet and leg conformation traits ranged from 0.04 to 0.11. Posterior standard deviation of heritability was ≤0.01 for all traits. Genetic correlations between claw disorders and feet and leg conformation traits were all low or moderate, except between corkscrew claw and hoof quality (-0.86), which are supposed to measure the same trait. The genetic correlations between rear leg rear view (new) and infectious claw disorders (-0.20) and laminitis-related claw disorders (0.26), and between hoof quality and laminitis-related claw disorders (-0.33) were moderate. Eight of the 15 genetic correlations between claw disorders and feet and leg conformation traits had 0

  19. Volume measurement of the leg with the depth camera for quantitative evaluation of edema

    Science.gov (United States)

    Kiyomitsu, Kaoru; Kakinuma, Akihiro; Takahashi, Hiroshi; Kamijo, Naohiro; Ogawa, Keiko; Tsumura, Norimichi

    2017-02-01

    Volume measurement of the leg is important in the evaluation of leg edema. Recently, method for measurement by using a depth camera is proposed. However, many depth cameras are expensive. Therefore, we propose a method using Microsoft Kinect. We obtain a point cloud of the leg by Kinect Fusion technique and calculate the volume. We measured the volume of leg for three healthy students during three days. In each measurement, the increase of volume was confirmed from morning to evening. It is known that the volume of leg is increased in doing office work. Our experimental results meet this expectation.

  20. Burning Cold: Involvement of TRPA1 in Noxious Cold Sensation

    OpenAIRE

    Kwan, Kelvin Y.; Corey, David P.

    2009-01-01

    Soon after its discovery ten years ago, the ion channel TRPA1 was proposed as a sensor of noxious cold. Evidence for its activation by painfully cold temperatures (below ~15° C) has been mixed, however. Some groups found that cold elicits a nonselective conductance in cells expressing TRPA1; others found no activation, or argued that activation is an indirect effect of elevated \\(Ca^{ 2+}\\) . Sensory cells from the trigeminal and dorsal root ganglia that are activated by cold were sometimes c...

  1. Self-Healable and Cold-Resistant Supercapacitor Based on a Multifunctional Hydrogel Electrolyte.

    Science.gov (United States)

    Tao, Feng; Qin, Liming; Wang, Zhikui; Pan, Qinmin

    2017-05-10

    Excellent self-healability and cold resistance are attractive properties for a portable/wearable energy-storage device. However, achieving the features is fundamentally dependent on an intrinsically self-healable electrolyte with high ionic conduction at low temperature. Here we report such a hydrogel electrolyte comprising sodium alginate cross-linked by dynamic catechol-borate ester bonding. Since its dynamically cross-linked alginate network can tolerate high-content inorganic salts, the electrolyte possesses excellent healing efficiency/cyclability but also high ionic conduction at both room temperature and low temperature. A supercapacitor with the multifunctional hydrogel electrolyte completely restores its capacitive properties even after breaking/healing for 10 cycles without external stimulus. At a low temperature of -10 °C, the capacitor is even able to maintain at least 80% of its room-temperature capacitance. Our investigations offer a strategy to assemble self-healable and cold-resistant energy storage devices by using a multifunctional hydrogel electrolyte with rationally designed polymeric networks, which has potential application in portable/wearable electronics, intelligent apparel or flexible robot, and so on.

  2. Effects of combined high intensity arm and leg training on performance and cardio-respiratory measures.

    Science.gov (United States)

    Zinner, Christoph; Sperlich, Billy; Born, Dennis-Peter; Michels, Guido

    2017-01-01

    The purpose of this study was to investigate the effects of combined arm and leg high-intensity low-volume interval training (HIITarm+leg) on maximal oxygen uptake, myocardial measures (i.e. stroke volume, cardiac output, ejection fraction), Tissue Oxygenation Index (TOI) of the vastus lateralis and triceps brachii, as well as power output in comparison to leg HIIT (HIITleg) only. The 20 healthy, male and female volunteers completed six sessions of either HIITleg on a cycle ergometer or HIITarm+leg on an arm and leg cycle ergometer. During pre- and post-testing, the volunteers completed a submaximal and incremental test to exhaustion on a cycle ergometer. Magnitude based interference revealed likely to very likely beneficial effects for HIITarm+leg compared to HIITleg in maximal oxygen uptake, cardiac measures as well peak power output. The TOI following HIITarm+leg demonstrated likely to very likely increased oxygenation in the triceps brachii or the vastus lateralis when compared to HIITleg. The results suggest that six sessions of HIITarm+leg may likely to very likely improve maximal oxygen uptake, some inotropy-related cardiac measures with improved tissue oxygenation of the triceps brachii and vastus lateralis muscles resulting in greater leg peak power output.

  3. Gait Planning Research for an Electrically Driven Large-Load-Ratio Six-Legged Robot

    Directory of Open Access Journals (Sweden)

    Hong-Chao Zhuang

    2017-03-01

    Full Text Available Gait planning is an important basis for the walking of a legged robot. To improve the walking stability of multi-legged robots and to reduce the impact force between the foot and the ground, gait planning strategies are presented for an electrically driven large-load-ratio six-legged robot. First, the configuration and walking gait of the electrically driven large-load-ratio six-legged robot are designed. The higher-stable swing sequences of legs and typical walking modes are respectively obtained. Based on the Denavit–Hartenberg (D–H method, the analyses of the forward and inverse kinematics are implemented. The mathematical models of the articulated rotation angles are respectively established. In view of the buffer device installed at the end of shin to decrease the impact force between the foot and the ground, an initial lift height of the leg is brought into gait planning when the support phase changes into the transfer phase. The mathematical models of foot trajectories are established. Finally, a prototype of the electrically driven large-load-ratio six-legged robot is developed. The experiments of the prototype are carried out regarding the aspects of the walking speed and surmounting obstacle. Then, the reasonableness of gait planning is verified based on the experimental results. The proposed strategies of gait planning lay the foundation for effectively reducing the foot–ground impact force and can provide a reference for other large-load-ratio multi-legged robots.

  4. Small break LOCA analysis for YGN 5 and 6 RCP trip strategy in power mode operation

    International Nuclear Information System (INIS)

    Kim, Tech Mo; Choi, Han Rim

    2001-01-01

    A continued operation of Reactor Coolant Pumps(RCPs) during a Small Break Loss of Coolant Accident(SBLOCA) in all operation mode may increase unnecessary inventory loss from the Reactor Coolant System(RCS) causing a severe core uncovery which might lead to fuel failure. After Three Mile Island Unit 2(TMI-2) accident, the Combustion Engineering Owner Group(CEOG) developed RCP trip strategy called 'Trip-Two/Leave-Two' (T2/L2). The T2/L2 RCP trip strategy consists of tripping the first two RCPs on low RCS pressure and then tripping the remaining two RCPs if a LOCA has occurred. This analysis demonstrates the inherent safety of RCP trip strategy during an SBLOCA for Youggwang Nuclear Power Plant Unit 5 and 6(YGN 5 and 6). The trip setpoint of the first two RCPs for YGN 5 and 6 is calculated to be 1721 psia in pressurizer pressure based on the limiting SBLOCA with 0.15 ft 2 break size in the hot leg. The analysis results show that YGN 5 and 6 can maintain the core coolability even if the operator fails to trip the second two RCPs or trips at the worst time of minimum liquid inventory

  5. Gauge symmetry breaking

    International Nuclear Information System (INIS)

    Weinberg, S.

    1976-01-01

    The problem of how gauge symmetries of the weak interactions get broken is discussed. Some reasons why such a heirarchy of gauge symmetry breaking is needed, the reason gauge heirarchies do not seem to arise in theories of a given and related type, and the implications of theories with dynamical symmetry breaking, which can exhibit a gauge hierarchy

  6. Leg og læring

    DEFF Research Database (Denmark)

    Pedersen, Annette

    2008-01-01

    Leg synes at have et potentiale som metode til at fremme læring. Men hvordan? Legen har en vis grad af parallelitet med den virkelige verden i dens interaktive og relationelle strukturer. Det bliver muligt at finde nye meninger i interaktioner, som refererer til vante interaktionsformer, men...

  7. [AA amyloidosis: a little-known complication of chronic leg ulcer].

    Science.gov (United States)

    Waton, J; Fays-Michel, S; Chandeclerc, M L; Corby, S; Cuny, J F; Barbaud, A; Schmutz, J-L

    2008-02-01

    AA amyloidosis, secondary to inflammatory chronic diseases like rheumatoid arthritis, is often complicated by renal failure. Chronic inflammatory dermatoses constitute rare causes of AA amyloidosis. We describe two cases of AA amyloidosis discovered after renal failure in patients presenting leg ulcers for several years. AL amyloidosis was suspected in both cases because of a history of monoclonal gammopathy in one patient and of plasmocytoma in the other. The diagnosis of AA amyloidosis was confirmed on renal histology through the detection of AA antibodies in amyloid deposits. No extrarenal amyloidosis was seen in either patient and there were no inflammatory diseases other than chronic leg ulcers. AA amyloidosis is caused by serum amyloid protein A (SAA), a reactive inflammatory protein. AA amyloidosis is thus caused by chronic inflammatory diseases, but only rarely by cutaneous inflammatory diseases. To our knowledge, the literature contains only seven other published cases of AA amyloidosis secondary to chronic leg ulcers. A review of the literature does not indicate whether cure of ulcers has any effect on the accompanying renal failure. We imagine that AA amyloidosis secondary to leg ulcer is in fact under-diagnosed. However, since the first specific treatment for AA amyloidosis is currently being evaluated by the Food and Drug Administration, it is essential that this serious complication of chronic leg ulcers be widely recognised.

  8. Cold-Hearted or Cool-Headed: Physical Coldness Promotes Utilitarian Moral Judgment

    Directory of Open Access Journals (Sweden)

    Hiroko eNakamura

    2014-10-01

    Full Text Available In the current study, we examine the effect of physical coldness on personal moral dilemma judgment. Previous studies have indicated that utilitarian moral judgment—sacrificing a few people to achieve the greater good for others—was facilitated when: (1 participants suppressed an initial emotional response and deliberately thought about the utility of outcomes; (2 participants had a high-level construal mindset and focused on abstract goals (e.g., save many; or (3 there was a decreasing emotional response to sacrificing a few. In two experiments, we exposed participants to extreme cold or typical room temperature and then asked them to make personal moral dilemma judgments. The results of Experiment 1 indicated that coldness prompted utilitarian judgment, but the effect of coldness was independent from deliberate thought or abstract high-level construal mindset. As Experiment 2 revealed, coldness facilitated utilitarian judgment via reduced empathic feelings. Therefore, physical coldness did not affect the cool-headed deliberate process or the abstract high-level construal mindset. Rather, coldness biased people toward being cold-hearted, reduced empathetic concern about a sacrificed victim, and facilitated utilitarian moral judgments.

  9. Pictorial essay: Ultrasonography in 'tennis leg'.

    Science.gov (United States)

    Shah, Jeshil R; Shah, Bipin R; Shah, Ankit B

    2010-11-01

    Tennis leg is caused by a rupture of the medial head of the gastrocnemius muscle, usually at its distal musculotendinous junction region. However, tears in this muscle and its tendon are also included under the term 'tennis leg'. It is seen regularly in practice and is an important cause of a painful calf. The common USG findings include: disruption of the pinnate pattern of the distal medial gastrocnemius, usually near the junction of the triceps surae (which is the echogenic line between the gastrocnemius, the soleus, and the plantaris muscles), fluid tracking along the fascia, adjacent hematoma, and intramuscular tears as well as hematomas. USG is useful for confirming the diagnosis, excluding other causes of a painful calf, for assessing the severity of the disease, and in follow-up.

  10. Hox gene expression leads to differential hind leg development between honeybee castes.

    Science.gov (United States)

    Bomtorin, Ana Durvalina; Barchuk, Angel Roberto; Moda, Livia Maria; Simoes, Zila Luz Paulino

    2012-01-01

    Beyond the physiological and behavioural, differences in appendage morphology between the workers and queens of Apis mellifera are pre-eminent. The hind legs of workers, which are highly specialized pollinators, deserve special attention. The hind tibia of worker has an expanded bristle-free region used for carrying pollen and propolis, the corbicula. In queens this structure is absent. Although the morphological differences are well characterized, the genetic inputs driving the development of this alternative morphology remain unknown. Leg phenotype determination takes place between the fourth and fifth larval instar and herein we show that the morphogenesis is completed at brown-eyed pupa. Using results from the hybridization of whole genome-based oligonucleotide arrays with RNA samples from hind leg imaginal discs of pre-pupal honeybees of both castes we present a list of 200 differentially expressed genes. Notably, there are castes preferentially expressed cuticular protein genes and members of the P450 family. We also provide results of qPCR analyses determining the developmental transcription profiles of eight selected genes, including abdominal-A, distal-less and ultrabithorax (Ubx), whose roles in leg development have been previously demonstrated in other insect models. Ubx expression in workers hind leg is approximately 25 times higher than in queens. Finally, immunohistochemistry assays show that Ubx localization during hind leg development resembles the bristles localization in the tibia/basitarsus of the adult legs in both castes. Our data strongly indicate that the development of the hind legs diphenism characteristic of this corbiculate species is driven by a set of caste-preferentially expressed genes, such as those encoding cuticular protein genes, P450 and Hox proteins, in response to the naturally different diets offered to honeybees during the larval period.

  11. China–Burma Geopolitical Relations in the Cold War

    Directory of Open Access Journals (Sweden)

    Hongwei FAN

    2012-01-01

    Full Text Available This paper explores the historical role of geography in the Sino–Burmese relationship in the context of the Cold War, both before and after the Chinese–American détente and rapprochement in the 1970s. It describes Burma’s fear and distrust of China throughout the Cold War, during which it maintained a policy of neutrality and non-alignment. Burma’s geographic location, sandwiched between its giant neighbours India and China, led it to adopt a realist paradigm and pursue an independent foreign policy. Charac-terizing China’s threat to Burmese national security as “grave” during its period of revolutionary export, the article notes that Burma was cowed into deference and that it deliberately avoided antagonizing China. It also looks at the history of China’s attempts to break out of U.S. encirclement after the Korean War and its successful establishment of Burma as an important buffer state. After the U.S.–China rapprochement in 1972, however, Bur-ma’s geographical significance for Beijing declined. In this context, Burma’s closed-door policy of isolation further lessened its strategic importance for China. Since 1988, however, Burma’s strategic importance to China has been on the rise once again, as it plays a greater role as China’s land bridge to the Indian Ocean and in its energy security and expansion of trade and exports.

  12. RELAP5/MOD 3.2 Analysis of the Loss of RHR System Experiment Scaled to NPP Krsko

    International Nuclear Information System (INIS)

    Bencik, V.; Bajs, T.; Prah, M.

    1998-01-01

    In the paper the RELAP5/MOD 3.2 analysis of the loss of Residual Heat Removal (RHR) system during midloop operation experiment performed at the Rig of Safety Assessment (ROSA)-IV/Large Scale Test Facility (LSTF) together with the analysis of the same test scenario scaled to NPP Krsko are presented. The experiment consisted in a loss of the RHR system at cold shutdown conditions along with a 5% cold leg break in the loop without pressurizer. The Safety Injection (SI) system was disable in the calculation. The aims of the work were to study the physical phenomena encountered under low power and low system pressure conditions while the upper part of the Reactor Coolant System (RCS) is filled with noncondensable. The impact of the bypass flow between upper plenum and downcomer inlet on transient responses was investigated. The transient was simulated for 6000 s. (author)

  13. GABAergic inhibition of leg motoneurons is required for normal walking behavior in freely moving Drosophila.

    Science.gov (United States)

    Gowda, Swetha B M; Paranjpe, Pushkar D; Reddy, O Venkateswara; Thiagarajan, Devasena; Palliyil, Sudhir; Reichert, Heinrich; VijayRaghavan, K

    2018-02-27

    Walking is a complex rhythmic locomotor behavior generated by sequential and periodical contraction of muscles essential for coordinated control of movements of legs and leg joints. Studies of walking in vertebrates and invertebrates have revealed that premotor neural circuitry generates a basic rhythmic pattern that is sculpted by sensory feedback and ultimately controls the amplitude and phase of the motor output to leg muscles. However, the identity and functional roles of the premotor interneurons that directly control leg motoneuron activity are poorly understood. Here we take advantage of the powerful genetic methodology available in Drosophila to investigate the role of premotor inhibition in walking by genetically suppressing inhibitory input to leg motoneurons. For this, we have developed an algorithm for automated analysis of leg motion to characterize the walking parameters of wild-type flies from high-speed video recordings. Further, we use genetic reagents for targeted RNAi knockdown of inhibitory neurotransmitter receptors in leg motoneurons together with quantitative analysis of resulting changes in leg movement parameters in freely walking Drosophila Our findings indicate that targeted down-regulation of the GABA A receptor Rdl (Resistance to Dieldrin) in leg motoneurons results in a dramatic reduction of walking speed and step length without the loss of general leg coordination during locomotion. Genetically restricting the knockdown to the adult stage and subsets of motoneurons yields qualitatively identical results. Taken together, these findings identify GABAergic premotor inhibition of motoneurons as an important determinant of correctly coordinated leg movements and speed of walking in freely behaving Drosophila . Copyright © 2018 the Author(s). Published by PNAS.

  14. Leg ulcer assessment techniques in a remote rural area.

    Science.gov (United States)

    Graham, Julia

    Community-based leg ulcer clinics are a cost-effective and efficient way of managing patients with leg ulcers in the community (Blair et al, 1988; Moffatt and Oldroyd, 1994). According to the Scottish Clinical Standards for Vascular Services (NHS Quality Improvement Scotland, 2003): 'It is essential that all vascular patients are seen by a nurse with vascular expertise, who is able to provide information, support and health promotion advice'.

  15. Compression therapy in patients with venous leg ulcers.

    Science.gov (United States)

    Dissemond, Joachim; Assenheimer, Bernd; Bültemann, Anke; Gerber, Veronika; Gretener, Silvia; Kohler-von Siebenthal, Elisabeth; Koller, Sonja; Kröger, Knut; Kurz, Peter; Läuchli, Severin; Münter, Christian; Panfil, Eva-Maria; Probst, Sebastian; Protz, Kerstin; Riepe, Gunnar; Strohal, Robert; Traber, Jürg; Partsch, Hugo

    2016-11-01

    Wund-D.A.CH. is the umbrella organization of the various wound care societies in German-speaking countries. The present consensus paper on practical aspects pertinent to compression therapy in patients with venous leg ulcers was developed by experts from Germany, Austria, and Switzerland. In Europe, venous leg ulcers rank among the most common causes of chronic wounds. Apart from conservative and interventional wound and vein treatment, compression therapy represents the basis of all other therapeutic strategies. To that end, there are currently a wide variety of materials and systems available. While especially short-stretch bandages or multicomponent systems should be used in the initial decongestion phase, ulcer stocking systems are recommended for the subsequent maintenance phase. Another - to date, far less common - alternative are adaptive Velcro bandage systems. Medical compression stockings have proven particularly beneficial in the prevention of ulcer recurrence. The large number of treatment options currently available enables therapists to develop therapeutic concepts geared towards their patients' individual needs and abilities, thus resulting in good acceptance and adherence. Compression therapy plays a crucial role in the treatment of patients with venous leg ulcers. In recent years, a number of different treatment options have become available, their use and application differing among German-speaking countries. The present expert consensus is therefore meant to outline concrete recommendations for routine implementation of compression therapy in patients with venous leg ulcers. © 2016 Deutsche Dermatologische Gesellschaft (DDG). Published by John Wiley & Sons Ltd.

  16. Dynamic breaking of a single gold bond

    DEFF Research Database (Denmark)

    Pobelov, Ilya V.; Lauritzen, Kasper Primdal; Yoshida, Koji

    2017-01-01

    While one might assume that the force to break a chemical bond gives a measure of the bond strength, this intuition is misleading. If the force is loaded slowly, thermal fluctuations may break the bond before it is maximally stretched, and the breaking force will be less than the bond can sustain...... of a single Au-Au bond and show that the breaking force is dependent on the loading rate. We probe the temperature and structural dependencies of breaking and suggest that the paradox can be explained by fast breaking of atomic wires and slow breaking of point contacts giving very similar breaking forces....

  17. Association of restless legs syndrome, pain, and mood disorders in Parkinson's disease.

    Science.gov (United States)

    Rana, Abdul Qayyum; Qureshi, Abdul Rehman M; Rahman, Labiba; Jesudasan, Ajantha; Hafez, Kevin K; Rana, Mohammad A

    2016-01-01

    The objectives of the study were to analyze the association between Parkinson's disease and restless legs syndrome, and to explore the relationship between mood disorder comorbidity (anxiety and depression), pain, and restless legs syndrome. This study included 123 Parkinson's disease patients and 123 non-Parkinson's disease patients matched for age and gender, and evaluated for anxiety severity, depression severity, pain severity, pain interference, pain disability, and restless legs syndrome prevalence. This was performed using semi-structured interviews and a neurological examination through the restless legs syndrome diagnostic criteria and the following inventories; Hospital Anxiety and Depression Scale, Brief Pain Inventory, and Pain Disability Index. Parkinson's disease patients had significantly greater anxiety severity, depression severity, pain severity, pain interference, pain disability, and restless legs syndrome prevalence in comparison to controls. In addition, Parkinson's disease patients' comorbid for anxiety and depression had significantly greater pain severity, pain interference, and pain disability, but not RLS prevalence, in comparison to Parkinson's disease only, Parkinson's disease anxiety, and Parkinson's disease depression patients. Pain interference, pain severity, and pain disability is greater among Parkinson's disease patients with anxiety and depression, in comparison to Parkinson's disease patients without anxiety and depression. On the contrary, the prevalence of restless legs syndrome was not found to be relevant.

  18. Electroweak breaking in supersymmetric models

    CERN Document Server

    Ibáñez, L E

    1992-01-01

    We discuss the mechanism for electroweak symmetry breaking in supersymmetric versions of the standard model. After briefly reviewing the possible sources of supersymmetry breaking, we show how the required pattern of symmetry breaking can automatically result from the structure of quantum corrections in the theory. We demonstrate that this radiative breaking mechanism works well for a heavy top quark and can be combined in unified versions of the theory with excellent predictions for the running couplings of the model. (To be published in ``Perspectives in Higgs Physics'', G. Kane editor.)

  19. Myonecrosis in the leg caused by Salmonella enteritidis

    DEFF Research Database (Denmark)

    Jørring, S; Kolmos, H J; Klareskov, B

    1994-01-01

    Five weeks after an episode of gastroenteritis, a 65-year-old diabetic male developed an extensive myonecrosis, with gas production in the left leg caused by Salmonella enteritidis. The patient was treated with surgical revision and antibiotics. To our knowledge, this is the first case of myonecr......Five weeks after an episode of gastroenteritis, a 65-year-old diabetic male developed an extensive myonecrosis, with gas production in the left leg caused by Salmonella enteritidis. The patient was treated with surgical revision and antibiotics. To our knowledge, this is the first case...

  20. Simulation of breaking waves using the high-order spectral method with laboratory experiments: wave-breaking energy dissipation

    Science.gov (United States)

    Seiffert, Betsy R.; Ducrozet, Guillaume

    2018-01-01

    We examine the implementation of a wave-breaking mechanism into a nonlinear potential flow solver. The success of the mechanism will be studied by implementing it into the numerical model HOS-NWT, which is a computationally efficient, open source code that solves for the free surface in a numerical wave tank using the high-order spectral (HOS) method. Once the breaking mechanism is validated, it can be implemented into other nonlinear potential flow models. To solve for wave-breaking, first a wave-breaking onset parameter is identified, and then a method for computing wave-breaking associated energy loss is determined. Wave-breaking onset is calculated using a breaking criteria introduced by Barthelemy et al. (J Fluid Mech https://arxiv.org/pdf/1508.06002.pdf, submitted) and validated with the experiments of Saket et al. (J Fluid Mech 811:642-658, 2017). Wave-breaking energy dissipation is calculated by adding a viscous diffusion term computed using an eddy viscosity parameter introduced by Tian et al. (Phys Fluids 20(6): 066,604, 2008, Phys Fluids 24(3), 2012), which is estimated based on the pre-breaking wave geometry. A set of two-dimensional experiments is conducted to validate the implemented wave breaking mechanism at a large scale. Breaking waves are generated by using traditional methods of evolution of focused waves and modulational instability, as well as irregular breaking waves with a range of primary frequencies, providing a wide range of breaking conditions to validate the solver. Furthermore, adjustments are made to the method of application and coefficient of the viscous diffusion term with negligible difference, supporting the robustness of the eddy viscosity parameter. The model is able to accurately predict surface elevation and corresponding frequency/amplitude spectrum, as well as energy dissipation when compared with the experimental measurements. This suggests the model is capable of calculating wave-breaking onset and energy dissipation

  1. Dynamically Stable Legged Locomotion

    Science.gov (United States)

    1981-11-30

    the laboratory. Harry Asada, Wayne Book, Nancy Cornelius, Sesh Murthy and Ivan Sutherland read various drafts of this report, for which we are...particularly helpful in providing an atmosphere where things could get started. Craig Fields and Clint Kelly deserve special credit for letting the idea of...legged technology capture their imaginations, even before we could show them tangible results. We are especially indebted to Ivan Sutherland for his

  2. Grooved cold moderator tests

    International Nuclear Information System (INIS)

    Inoue, K.; Kiyanagi, Y.; Iwasa, H.; Watanabe, N.; Ikeda, S.; Carpenter, J.M.; Ishikawa, Y.

    1983-01-01

    We performed some grooved cold moderator experiments for methane at 20 K by using the Hokkaido University linac to obtain information to be used in the planning of the KENS-I' project. Cold neutron gains, spatial distribution of emitted beams and time distribution of the neutrons in the grooved cold moderator were measured. Furthermore, we assessed the effects of the grooved cold moderator on the performances of the spectrometers presently installed at the KENS-I cold source. We concluded that the grooved cold moderator benefited appreciably the performances of the spectrometers

  3. A randomised clinical trial of the efficacy of drop squats or leg extension/leg curl exercises to treat clinically diagnosed jumper's knee in athletes: pilot study

    Science.gov (United States)

    Cannell, L; Taunton, J; Clement, D; Smith, C; Khan, K

    2001-01-01

    Objectives—To compare the therapeutic effect of two different exercise protocols in athletes with jumper's knee. Methods—Randomised clinical trial comparing a 12 week programme of either drop squat exercises or leg extension/leg curl exercises. Measurement was performed at baseline and after six and 12 weeks. Primary outcome measures were pain (visual analogue scale 1–10) and return to sport. Secondary outcome measures included quadriceps and hamstring moment of force using a Cybex II isokinetic dynamometer at 30°/second. Differences in pain response between the drop squat and leg extension/curl treatment groups were assessed by 2 (group) x 3 (time) analysis of variance. Two by two contingency tables were used to test differences in rates of return to sport. Analysis of variance (2 (injured versus non-injured leg) x 2 (group) x 3 (time)) was also used to determine differences for secondary outcome measures. Results—Over the 12 week intervention, pain diminished by 2.3 points (36%) in the leg extension/curl group and 3.2 points (57%) in the squat group. There was a significant main effect of both exercise protocols on pain (psquat group returned to sporting activity by 12 weeks, but five of those subjects still had low level pain. Six of nine of the leg extension/curl group returned to sporting activity by 12 weeks and four patients had low level pain. There was no significant difference between groups in numbers returning to sporting activity. There were no differences in the change in quadriceps or hamstring muscle moment of force between groups. Conclusions—Progressive drop squats and leg extension/curl exercises can reduce the pain of jumper's knee in a 12 week period and permit a high proportion of patients to return to sport. Not all patients, however, return to sport by that time. Key Words: knee; patellar tendon; tendinopathy; tendinosis; eccentric strengthening; strength training PMID:11157465

  4. Balanced gait generations of a two-legged robot on sloping surface

    Indian Academy of Sciences (India)

    legged robot moving up and down through the sloping surface is presented. The gait of the lower links during locomotion is obtained after assuming suitable trajectories for the swing leg and hip joint. The trunk motion is initially generated based on ...

  5. Near infrared spectroscopy for controlling the quality of distal leg perfusion in remote access cardiopulmonary bypass.

    Science.gov (United States)

    Schachner, Thomas; Bonaros, Nikolaos; Bonatti, Johannes; Kolbitsch, Christian

    2008-12-01

    The prevention of leg ischemia is necessary in all patients undergoing femoral artery cannulation for extracorporeal circulation. Near infrared spectroscopy (NIRS) is an established non-invasive method for measuring tissue oxygen saturation. Ten patients underwent robotically assisted endoscopic coronary surgery or ASD repair on the arrested heart using aortic endo-occlusion catheters. They were monitored by transcutaneous NIRS (placed on both lower legs) for quality control of distal leg perfusion during femoral access cardiopulmonary bypass. The baseline NIRS values were 61 (52-80) on the cannulated side versus 70 (53-80) on the contralateral leg (p=n.s.). During clamping of the femoral artery for installation of the remote access perfusion system the tissue oxygen saturation dropped to 38 (18-58) (p=0.001 vs baseline) while it remained stable on the contralateral leg. After successful implantation of the distal leg perfusion the NIRS values normalized to similar amounts on both legs. We conclude that transcutaneous NIRS of the lower legs might be a useful non-invasive tool for monitoring leg perfusion in patients undergoing extracorporeal circulation via the femoral vessels.

  6. Dynamic legged locomotion in robots and animals

    Science.gov (United States)

    Raibert, Marc; Playter, Robert; Ringrose, Robert; Bailey, Dave; Leeser, Karl

    1995-01-01

    This report documents our study of active legged systems that balance actively and move dynamically. The purpose of this research is to build a foundation of knowledge that can lead both to the construction of useful legged vehicles and to a better understanding of how animal locomotion works. In this report we provide an update on progress during the past year. Here are the topics covered in this report: (1) Is cockroach locomotion dynamic? To address this question we created three models of cockroaches, each abstracted at a different level. We provided each model with a control system and computer simulation. One set of results suggests that 'Groucho Running,' a type of dynamic walking, seems feasible at cockroach scale. (2) How do bipeds shift weight between the legs? We built a simple planar biped robot specifically to explore this question. It shifts its weight from one curved foot to the other, using a toe-off and toe-on strategy, in conjunction with dynamic tipping. (3) 3D biped gymnastics: The 3D biped robot has done front somersaults in the laboratory. The robot changes its leg length in flight to control rotation rate. This in turn provides a mechanism for controlling the landing attitude of the robot once airborne. (4) Passively stabilized layout somersault: We have found that the passive structure of a gymnast, the configuration of masses and compliances, can stabilize inherently unstable maneuvers. This means that body biomechanics could play a larger role in controlling behavior than is generally thought. We used a physical 'doll' model and computer simulation to illustrate the point. (5) Twisting: Some gymnastic maneuvers require twisting. We are studying how to couple the biomechanics of the system to its control to produce efficient, stable twisting maneuvers.

  7. Genetic association between leg conformation in young pigs and sow reproduction

    DEFF Research Database (Denmark)

    Le, Thu Hong; Nilsson, Katja; Norberg, Elise

    2015-01-01

    Lameness is an issue of concern in pig production due both to animal welfare and to economical aspects. Lame sows are believed to suffer from pain and stress which is reported to have a negative influence on reproduction. Leg conformation and locomotion traits in young animals are associated...... with the risk of lameness at higher age. The purpose of this study was to estimate the genetic parameters of leg conformation traits recorded at performance testing (around 5 months of age) and their genetic correlations with reproduction traits. Information on leg conformation traits from 123,307 pigs scored...... and on reproduction traits from 22,204 litters in the first and second parity from Swedish Yorkshire nucleus herds were available for genetic analysis. Eight conformation and locomotion traits, coming from the old or the new scoring system in Sweden, included old movement, old overall leg score, new movement, new...

  8. Dual descriptions of supersymmetry breaking

    International Nuclear Information System (INIS)

    Intrilligator, K.; Thomas, S.

    1996-08-01

    Dynamical supersymmetry breaking is considered in models which admit descriptions in terms of electric, confined, or magnetic degrees of freedom in various limits. In this way, a variety of seemingly different theories which break supersymmetry are actually interrelated by confinement or duality. Specific examples are given in which there are two dual descriptions of the supersymmetry breaking ground state

  9. Normalized knee-extension strength or leg-press power after fast-track total knee arthroplasty

    DEFF Research Database (Denmark)

    Aalund, Peter K; Larsen, Kristian; Hansen, Torben Bæk

    2013-01-01

    OBJECTIVE: (s): To investigate which of the two muscle-impairment measures for the operated leg, normalized knee extension strength or leg press power, is more closely associated to performance-based and self-reported measures of function shortly following total knee arthroplasty (TKA). DESIGN...... and dynamic leg presses to determine their body-mass normalized knee extension strength and leg press power, respectively. The 10-m fast speed walking and 30-s chair stand tests were used to determine performance-based function, while the Western Ontario McMaster University Osteoarthritis Index (WOMAC......) and Oxford Knee scores were used to determine self-reported function. RESULTS: Normalized leg press power was more closely associated to both performance-based (r=.82, P...

  10. Quarterly technical progress report on water reactor safety programs sponsored by the Nuclear Regulatory Commission's Division of Reactor Safety Research, January--March 1977

    Energy Technology Data Exchange (ETDEWEB)

    Card, D. H. [ed.

    1977-06-01

    A test series to evaluate the effectiveness of different emergency core coolant injection arrangements was completed. A LOFT test series was initiated to investigate the effect of break nozzle geometry on break flow and system response during a 200 percent double-ended cold leg break test. Two analyses of results of LOFT nonnuclear experiments were made. The intact loop flow resistance on LOFT system responses during loss-of-coolant experiments was evaluated. The second in a series of five tests to evaluate the effects of fuel density, initial gap width, and fill gas composition on gap conductance was performed with four BWR-type rods tested simultaneously. A test was conducted to provide steady state, power ramp, and film boiling operation behavior data on the fuel rods constructed from irradiated and unirradiated cladding and to investigate the influence of simulated fission products on cladding integrity and performance. Cladding ballooning phenomena were also investigated. Results of preliminary postirradiation examinations of irradiation effects, power-cooling mismatch, and gap conductance tests performed previously are reported. A review of FLECHT and Semiscale forced feed and gravity feed reflood heat transfer experiments was performed. A study to predict and compare surface temperature response of Semiscale electrically heated rods with LOFT nuclear rods during a Semiscale blowdown was completed. SPERT and NSRR data were analyzed to evaluate fuel failure modes and the effect of energy deposition for cold-startup conditions.

  11. Leg loss in Lutzomyia longipalpis (Diptera: Psychodidae) due to pyrethroid exposure: Toxic effect or defense by autotomy?

    Science.gov (United States)

    Santamaría, E; Cabrera, O L; Avendaño, J; Pardo, R H

    2016-01-01

    Phlebotomine sandflies lose their legs after exposure to pyrethroids. In some insects leg loss helps to defend them from intoxication and predation, a phenomenon known as autotomy. A field observation has shown that sandflies that have lost some legs are still able to blood-feed. The aims of the study were to determine whether leg loss in sandflies, after exposure to deltamethrin, is due to autotomy and to establish the effect of the leg loss on blood-feeding. Two experiments were carried out with Lutzomyia longipalpis: (i) Females were individually exposed to a sublethal time of deltamethrin and mortality and the number of leg loss were recorded; and (ii) Groups of females with complete legs or with 1-3 legs lost due to pyrethroid exposure were offered a blood meal and percentages of blood-fed and fully-fed females were recorded. Most females lost a median of 1 leg within 1-48 h post-exposure to deltamethrin. Mortality (after 24 h) was significantly higher for exposed females with lost legs (31.1%), compared to exposed females with complete legs (7.3%), and there were no differences in mortality between females with complete legs and the control (unexposed females). There were no differences between the three treatments in the percentages of blood-fed and fully-fed females. Leg loss in sandflies is a toxic effect of pyrethroids and there was no evidence of autotomy. The loss of up to three legs after exposure to pyrethroids does not affect blood-feeding behaviour in laboratory and probably also in wild conditions.

  12. Living with clipped wings—Patients’ experience of losing a leg

    Directory of Open Access Journals (Sweden)

    Annelise Norlyk

    2013-10-01

    Full Text Available This study explores the lived experience of losing a leg as described by the patients themselves post-discharge. Studies have documented that regardless of aetiology patients are faced with severe physical as well as psychosocial challenges post-amputation. However, only few studies explore in-depth the patients’ perspective on the various challenges following the loss of a leg. The study uses the phenomenological approach of Reflective Lifeworld Research (RLR. Data were collected from 24 in-depth interviews with 12 Danish patients. Data analysis was performed according to the guidelines given in RLR. The essential meaning of losing a leg is a radical and existential upheaval, which restricts patients’ lifestyle and irretrievably alters their lifeworld. Life after the operation is associated with despair, and a painful sense of loss, but also with the hope of regaining personal independence. The consequences of losing a leg gradually materialize as the patients realize how the loss of mobility limits their freedom. Patients experience the professional help as primarily directed towards physical care and rehabilitation. The findings show that the loss of a leg and, subsequently, the restricted mobility carry with them an existential dimension which refers to limitation of action space and loss of freedom experienced as an exclusion from life. Our findings demonstrate a need for complementary care and stress the importance of an increased awareness of the psychosocial and existential consequences of losing a limb.

  13. Numerical analysis of single particle impact in the context of Cold Spray: a new adhesion model

    Science.gov (United States)

    Profizi, P.; Combescure, A.; Ogawa, K.

    2016-03-01

    A new adhesion model for numerical simulation of single particle impact in the context of Cold Spray is introduced. As in other studies, cohesive forces are put between the particle and substrate to account for adhesion. In this study however, the forces are put only when a local physical criterion is met. The physical phenomenon most often attributed to Cold Spray adhesion is a shear stress instability. The Johnson-Cook material law is used with a shear damage softening law to enable strong localization at the interface without the need for an extremely fine mesh. This localization is then detected as a drop in local yield stress value by the algorithm, which then implements a local cohesive force. The evolution of this cohesive force is defined by an energy dissipative cohesive model, using a surface adhesion energy as a material parameter. Each cohesive link is broken once all its associated surface energy is dissipated. A criterion on the damage value is also used to break a cohesive bond prematurely, to account for the effect of erosion at higher speeds. This model is found to reproduce the Cold Spray-like adhesion behavior with observed critical and maximum speeds.

  14. Second-leg home advantage in the Copa Libertadores da América (2005-2015

    Directory of Open Access Journals (Sweden)

    Cesar Cavinato Cal Abad

    2017-11-01

    Full Text Available ABSTRACT 24. Aims To investigate the home advantage (HA in the Copa Libertadores da América (CLA from 2005 to 2015. Methods A naive analysis was applied considering how many times a team that played the second leg at home qualified for the next round. To verify differences between home, away and draw results, the Chi-square ( χ2 and the Full Bayesian Significance Test were applied. For the binomial variables ("Home" or "Away", the probability of second-leg knockout occurrence was calculated. Results The probability of second-leg HA varied from 27.27% to 63.64% suggesting fluctuations of second-leg HA during competitive phases (round of 16, quarterfinals, semi-finals and final matches and decision forms (full time, goals away rule or penalty-shoots. Conclusion The results counteract the common belief that there is a large advantage to playing the second match of a two-leg tie at home during all competition phases. Penalty-shots seemed to affect positively the second-leg HA. Despite the causes of second leg HA in CLA need to be better investigated, soccer coaches could to use these results to think better strategies to win your knockout matches.

  15. R-parity breaking phenomenology

    International Nuclear Information System (INIS)

    Vissani, F.

    1996-02-01

    We review various features of the R-parity breaking phenomenology, with particular attention to the low energy observables, and to the patterns of the R-parity breaking interactions that arise in Grand Unified models. (author). 22 refs, 1 fig., 3 tabs

  16. Cold crystallization of polytetrafluoroethylene by γ irradiation

    International Nuclear Information System (INIS)

    Takenaga, M.; Yamagata, K.

    1980-01-01

    Changes in density and in the corresponding degree of crystallinity with radiation dose are studied experimentally for γ-irradiated polytetrafluoroethylene (PTFE) in the dose range from 1 x 10 3 to 1 x 10 9 R. The relation between the amorphous fraction and the radiation dose is derived from a quantitative analysis of cold crystallization by scission of polymer backbone chains. The characteristic radiation dose, at which one break occurs on the average per initial molecule, is estimated as about 3 x 10 4 R on the basis of a derived kinetic equation. The theoretical relation is modified by considering microvoids produced in the irradiated samples. The radii of microvoids in the form of spheres are evaluated as about 0.2 nm, and are also related to cage spheres relevant to the chain scission process. Good agreement between the modified theoretical relation and experimental data is attained over the entire range of radiation dose. 4 figures, 1 table

  17. Seed Germination Ecology of the Cold Desert Annual Isatis violascens (Brassicaceae: Two Levels of Physiological Dormancy and Role of the Pericarp.

    Directory of Open Access Journals (Sweden)

    Yuan M Zhou

    Full Text Available The occurrence of various species of Brassicaceae with indehiscent fruits in the cold deserts of NW China suggests that there are adaptive advantages of this trait. We hypothesized that the pericarp of the single-seeded silicles of Isatis violascens restricts embryo expansion and thus prevents germination for 1 or more years. Thus, our aim was to investigate the role of the pericarp in seed dormancy and germination of this species. The effects of afterripening, treatment with gibberellic acid (GA3 and cold stratification on seed dormancy-break were tested using intact silicles and isolated seeds, and germination phenology was monitored in an experimental garden. The pericarp has a role in mechanically inhibiting germination of fresh seeds and promotes germination of nondormant seeds, but it does not facilitate formation of a persistent seed bank. Seeds in silicles in watered soil began to germinate earlier in autumn and germinated to higher percentages than isolated seeds. Sixty-two percent of seeds in the buried silicles germinated by the end of the first spring, and only 3% remained nongerminated and viable. Twenty to twenty-five percent of the seeds have nondeep physiological dormancy (PD and 75-80% intermediate PD. Seeds with nondeep PD afterripen in summer and germinate inside the silicles in autumn if the soil is moist. Afterripening during summer significantly decreased the amount of cold stratification required to break intermediate PD. The presence of both nondeep and intermediate PD in the seed cohort may be a bet-hedging strategy.

  18. A comparison and update of direct kinematic-kinetic models of leg stiffness in human running.

    Science.gov (United States)

    Liew, Bernard X W; Morris, Susan; Masters, Ashleigh; Netto, Kevin

    2017-11-07

    Direct kinematic-kinetic modelling currently represents the "Gold-standard" in leg stiffness quantification during three-dimensional (3D) motion capture experiments. However, the medial-lateral components of ground reaction force and leg length have been neglected in current leg stiffness formulations. It is unknown if accounting for all 3D would alter healthy biologic estimates of leg stiffness, compared to present direct modelling methods. This study compared running leg stiffness derived from a new method (multiplanar method) which includes all three Cartesian axes, against current methods which either only include the vertical axis (line method) or only the plane of progression (uniplanar method). Twenty healthy female runners performed shod overground running at 5.0 m/s. Three-dimensional motion capture and synchronised in-ground force plates were used to track the change in length of the leg vector (hip joint centre to centre of pressure) and resultant projected ground reaction force. Leg stiffness was expressed as dimensionless units, as a percentage of an individual's bodyweight divided by standing leg length (BW/LL). Leg stiffness using the line method was larger than the uniplanar method by 15.6%BW/LL (P method by 24.2%BW/LL (P stiffness from the uniplanar method was larger than the multiplanar method by 8.5%BW/LL (6.5 kN/m) (P stiffness estimate with the multiplanar method. Given that limb movements typically occur in 3D, the new multiplanar method provides the most complete accounting of all force and length components in leg stiffness calculation. Copyright © 2017 Elsevier Ltd. All rights reserved.

  19. X-Ray Exam: Femur (Upper Leg)

    Science.gov (United States)

    ... Staying Safe Videos for Educators Search English Español X-Ray Exam: Femur (Upper Leg) KidsHealth / For Parents / X- ... Muscles, and Joints Broken Bones Getting an X-ray (Video) X-Ray (Video) View more Partner Message About Us ...

  20. Cold acclimation increases cold tolerance independently of diapause programing in the bean bug, Riptortus pedestris.

    Science.gov (United States)

    Rozsypal, J; Moos, M; Goto, S G

    2017-10-17

    The bean bug (Riptortus pedestris) is a pest of soybeans and other legumes in Japan and other Asian countries. It enters a facultative adult diapause on exposure to short days. While photoperiodism and diapause are well understood in R. pedestris, knowledge of cold tolerance is very limited, as is information on the effect of diapause on cold tolerance. We examined the effect of photoperiod, cold acclimation, and feeding status on cold tolerance in R. pedestris. We found that cold acclimation significantly increased survival at -10°C in both long- and short-day adult R. pedestris. Since the difference in cold survival between long- and short-day cold-acclimated groups was only marginal, we conclude that entering diapause is not crucial for R. pedestris to successfully pass through cold acclimation and become cold tolerant. We observed similar effects in 5th instar nymphs, with both long- and short-day cold-acclimated groups surviving longer cold exposures compared with non-acclimated groups. Starvation, which was tested only in adult bugs, had only a negligible and negative impact on cold survival. Although cold tolerance significantly increased with cold acclimation in adult bugs, supercooling capacity unexpectedly decreased. Our results suggest that changes in supercooling capacity as well as in water content are unrelated to cold tolerance in R. pedestris. An analysis of metabolites revealed differences between the treatments, and while several metabolites markedly increased with cold acclimation, their concentrations were too low to have a significant effect on cold tolerance.