WorldWideScience

Sample records for cold checkout test

  1. Prototypical Rod Construction Demonstration Project. Phase 3, Final report: Volume 1, Cold checkout test report, Book 3

    Energy Technology Data Exchange (ETDEWEB)

    1993-05-01

    The objective of Phase 3 of the Prototypical Rod consolidation Demonstration Project (PRCDP) was to procure, fabricate, assemble, and test the Prototypical Rod consolidation System as described in the NUS Phase 2 Final Design Report. This effort required providing the materials, components, and fabricated parts which makes up all of the system equipment. In addition, it included the assembly, installation, and setup of this equipment at the Cold Test Facility. During the Phase 3 effort the system was tested on a component, subsystem, and system level. This volume 1, discusses the PRCDP Phase 3 Test Program that was conducted by the HALLIBURTON NUS Environmental Corporation under contract AC07-86ID12651 with the United States Department of Energy. This document, Volume 1, Book 3 discusses the following topics: Downender Test Results and Analysis Report; NFBC Canister Upender Test Results and Analysis Report; Fuel Assembly Handling Fixture Test Results and Analysis Report; and Fuel Canister Upender Test Results and Analysis Report.

  2. Prototypical Rod Consolidation Demonstration Project. Phase 3, Final report: Volume 1, Cold checkout test report, Book 2

    Energy Technology Data Exchange (ETDEWEB)

    1993-05-01

    The objective of Phase 3 of the Prototypical Rod consolidation Demonstration Project (PRCDP) was to procure, fabricate, assemble, and test the Prototypical Rod consolidation System as described in the NUS Phase 2 Final Design Report. This effort required providing the materials, components, and fabricated parts which makes up all of the system equipment. In addition, it included the assembly, installation, and setup of this equipment at the Cold Test Facility. During the Phase 3 effort the system was tested on a component, subsystem, and system level. This volume 1, discusses the PRCDP Phase 3 Test Program that was conducted by the HALLIBURTON NUS Environmental Corporation under contract AC07-86ID12651 with the United States Department of Energy. This document, Volume 1, Book 2 discusses the following topics: Fuel Rod Extraction System Test Results and Analysis Reports and Clamping Table Test Results and Analysis Reports.

  3. Prototypical Rod Consolidation Demonstration Project. Phase 3, Final report: Volume 1, Cold checkout test report, Book 4

    Energy Technology Data Exchange (ETDEWEB)

    1993-05-01

    The objective of Phase 3 of the Prototypical Rod consolidation Demonstration Project (PRCDP) was to procure, fabricate, assemble, and test the Prototypical Rod consolidation System as described in the NUS Phase 2 Final Design Report. This effort required providing the materials, components, and fabricated parts which makes up all of the system equipment. In addition, it included the assembly, installation, and setup of this equipment at the Cold Test Facility. During the Phase 3 effort the system was tested on a component, subsystem, and system level. This volume 1, discusses the PRCDP Phase 3 Test Program that was conducted by the HALLIBURTON NUS Environmental Corporation under contract AC07-86ID12651 with the United States Department of Energy. This document, Volume 1, Book 4 discusses the following topics: Rod Compaction/Loading System Test Results and Analysis Report; Waste Collection System Test Results and Analysis Report; Waste Container Transfer Fixture Test Results and Analysis Report; Staging and Cutting Table Test Results and Analysis Report; and Upper Cutting System Test Results and Analysis Report.

  4. Measurement system performance during cold checkout runs at the BNFP

    Energy Technology Data Exchange (ETDEWEB)

    Ehinger, M.H.; Crawford, J.M.

    1978-01-01

    The measurement systems in a complex nuclear fuel plant such as the Barnwell Nuclear Fuel Plant rely on capabilities to remotely measure solution quantities and determine the nuclear material content of these solutions. During recent testing activities using natural uranium, a major objective of the NMC group was to demonstrate these solution measurement capabilities. Installed measurement systems at the BNFP use the most recent innovations in measurement equipment and techniques for remote solution measurement. This paper presents the measurement methods and results of the tests and evaluations. 6 figures.

  5. Biannular Airbreathing Nozzle Rig (BANR) facility checkout and plug nozzle performance test data

    Science.gov (United States)

    Cummings, Chase B.

    2010-09-01

    The motivation for development of a supersonic business jet (SSBJ) platform lies in its ability to create a paradigm shift in the speed and reach of commercial, private, and government travel. A full understanding of the performance capabilities of exhaust nozzle configurations intended for use in potential SSBJ propulsion systems is critical to the design of an aircraft of this type. Purdue University's newly operational Biannular Airbreathing Nozzle Rig (BANR) is a highly capable facility devoted to the testing of subscale nozzles of this type. The high accuracy, six-axis force measurement system and complementary mass flowrate measurement capabilities of the BANR facility make it rather ideally suited for exhaust nozzle performance appraisal. Detailed accounts pertaining to methods utilized in the proper checkout of these diagnostic capabilities are contained herein. Efforts to quantify uncertainties associated with critical BANR test measurements are recounted, as well. Results of a second hot-fire test campaign of a subscale Gulfstream Aerospace Corporation (GAC) axisymmetric, shrouded plug nozzle are presented. Determined test article performance parameters (nozzle thrust efficiencies and discharge coefficients) are compared to those of a previous test campaign and numerical simulations of the experimental set-up. Recently acquired data is compared to published findings pertaining to plug nozzle experiments of similar scale and operating range. Suggestions relating to the future advancement and improvement of the BANR facility are provided. Lessons learned with regards to test operations and calibration procedures are divulged in an attempt to aid future facility users, as well.

  6. Cold Stress and the Cold Pressor Test

    Science.gov (United States)

    Silverthorn, Dee U.; Michael, Joel

    2013-01-01

    Temperature and other environmental stressors are known to affect blood pressure and heart rate. In this activity, students perform the cold pressor test, demonstrating increased blood pressure during a 1- to 2-min immersion of one hand in ice water. The cold pressor test is used clinically to evaluate autonomic and left ventricular function. This…

  7. LADEE Propulsion System Cold Flow Test

    Science.gov (United States)

    Williams, Jonathan Hunter; Chapman, Jack M.; Trinh, Hau, P.; Bell, James H.

    2013-01-01

    Lunar Atmosphere and Dust Environment Explorer (LADEE) is a NASA mission that will orbit the Moon. Its main objective is to characterize the atmosphere and lunar dust environment. The spacecraft development is being led by NASA Ames Research Center and scheduled for launch in 2013. The LADEE spacecraft will be operated with a bi-propellant hypergolic propulsion system using MMH and NTO as the fuel and oxidizer, respectively. The propulsion system utilizes flight-proven hardware on major components. The propulsion layout is composed of one 100-lbf main thruster and four 5-lbf RCS thrusters. The propellants are stored in four tanks (two parallel-connected tanks per propellant component). The propellants will be pressurized by regulated helium. A simulated propulsion system has been built for conducting cold flow test series to characterize the transient fluid flow of the propulsion system feed lines and to verify the critical operation modes, such as system priming, waterhammer, and crucial mission duty cycles. Propellant drainage differential between propellant tanks will also be assessed. Since the oxidizer feed line system has a higher flow demand than the fuel system does, the cold flow test focuses on the oxidizer system. The objective of the cold flow test is to simulate the LADEE propulsion fluid flow operation through water cold flow test and to obtain data for anchoring analytical models. The models will be used to predict the transient and steady state flow behaviors in the actual flight operations. The test activities, including the simulated propulsion test article, cold flow test, and analytical modeling, are being performed at NASA Marshall Space Flight Center. At the time of the abstract submission, the test article checkout is being performed. The test series will be completed by November, 2012

  8. Integrated system checkout report

    Energy Technology Data Exchange (ETDEWEB)

    1991-08-14

    The planning and preparation phase of the Integrated Systems Checkout Program (ISCP) was conducted from October 1989 to July 1991. A copy of the ISCP, DOE-WIPP 90--002, is included in this report as an appendix. The final phase of the Checkout was conducted from July 10, 1991, to July 23, 1991. This phase exercised all the procedures and equipment required to receive, emplace, and retrieve contact handled transuranium (CH TRU) waste filled dry bins. In addition, abnormal events were introduced to simulate various equipment failures, loose surface radioactive contamination events, and personnel injury. This report provides a detailed summary of each days activities during this period. Qualification of personnel to safely conduct the tasks identified in the procedures and the abnormal events were verified by observers familiar with the Bin-Scale CH TRU Waste Test requirements. These observers were members of the staffs of Westinghouse WID Engineering, QA, Training, Health Physics, Safety, and SNL. Observers representing a number of DOE departments, the state of new Mexico, and the Defense Nuclear Facilities Safety Board observed those Checkout activities conducted during the period from July 17, 1991, to July 23, 1991. Observer comments described in this report are those obtained from the staff member observers. 1 figs., 1 tab.

  9. Test plan/procedure for the checkout of the USA cable communications test configuration for the electromagnetic compatibility (EMC) tests

    Science.gov (United States)

    Perry, J. C.

    1975-01-01

    A series of electromagnetic compatibility (EMC) tests were conducted in May, 1975 in the Soviet Union. The purpose of the EMC tests was to determine the effects of the operating environment of the Soviet aircraft, Soyuz, upon the electrical performance of the USA's cable communications equipment located in Soyuz. The test procedures necessary to check out the cable communications test configuration in preparation for the EMC tests are presented.

  10. Parallel Eclipse Project Checkout

    Science.gov (United States)

    Crockett, Thomas M.; Joswig, Joseph C.; Shams, Khawaja S.; Powell, Mark W.; Bachmann, Andrew G.

    2011-01-01

    Parallel Eclipse Project Checkout (PEPC) is a program written to leverage parallelism and to automate the checkout process of plug-ins created in Eclipse RCP (Rich Client Platform). Eclipse plug-ins can be aggregated in a feature project. This innovation digests a feature description (xml file) and automatically checks out all of the plug-ins listed in the feature. This resolves the issue of manually checking out each plug-in required to work on the project. To minimize the amount of time necessary to checkout the plug-ins, this program makes the plug-in checkouts parallel. After parsing the feature, a request to checkout for each plug-in in the feature has been inserted. These requests are handled by a thread pool with a configurable number of threads. By checking out the plug-ins in parallel, the checkout process is streamlined before getting started on the project. For instance, projects that took 30 minutes to checkout now take less than 5 minutes. The effect is especially clear on a Mac, which has a network monitor displaying the bandwidth use. When running the client from a developer s home, the checkout process now saturates the bandwidth in order to get all the plug-ins checked out as fast as possible. For comparison, a checkout process that ranged from 8-200 Kbps from a developer s home is now able to saturate a pipe of 1.3 Mbps, resulting in significantly faster checkouts. Eclipse IDE (integrated development environment) tries to build a project as soon as it is downloaded. As part of another optimization, this innovation programmatically tells Eclipse to stop building while checkouts are happening, which dramatically reduces lock contention and enables plug-ins to continue downloading until all of them finish. Furthermore, the software re-enables automatic building, and forces Eclipse to do a clean build once it finishes checking out all of the plug-ins. This software is fully generic and does not contain any NASA-specific code. It can be applied to any

  11. Healthy Checkout Lines: A Study in Urban Supermarkets.

    Science.gov (United States)

    Adjoian, Tamar; Dannefer, Rachel; Willingham, Craig; Brathwaite, Chantelle; Franklin, Sharraine

    2017-09-01

    To understand the impact of healthy checkouts in Bronx, New York City supermarkets. Consumer purchasing behavior was observed for 2 weeks in 2015. Three supermarkets in the South Bronx. A total of 2,131 adult shoppers (aged ≥18 years) who paid for their groceries at 1 of the selected study checkout lines. Two checkout lines were selected per store; 1 was converted to a healthy checkout and the other remained as it was (standard checkout). Data collectors observed consumer behavior at each line and recorded items purchased from checkout areas. Percentage of customers who purchase items from the checkout area; quantity and price of healthy and unhealthy items purchased from the healthy and standard checkout lines. Measures were analyzed by study condition using chi-square and t tests; significance was determined at α = .05. Only 4.0% of customers bought anything from the checkout area. A higher proportion of customers using the healthy vs standard checkout line bought healthy items (56.5% vs 20.5%; P healthy purchases increased. Findings contribute to limited research on effectiveness of healthy checkouts in supermarkets. Similar interventions should expect an increase in healthy purchases from the checkout area, but limited overall impact. Copyright © 2017 Society for Nutrition Education and Behavior. Published by Elsevier Inc. All rights reserved.

  12. Cold Flow Propulsion Test Complex Pulse Testing

    Science.gov (United States)

    McDougal, Kris

    2016-01-01

    When the propellants in a liquid rocket engine burn, the rocket not only launches and moves in space, it causes forces that interact with the vehicle itself. When these interactions occur under specific conditions, the vehicle's structures and components can become unstable. One instability of primary concern is termed pogo (named after the movement of a pogo stick), in which the oscillations (cycling movements) cause large loads, or pressure, against the vehicle, tanks, feedlines, and engine. Marshall Space Flight Center (MSFC) has developed a unique test technology to understand and quantify the complex fluid movements and forces in a liquid rocket engine that contribute strongly to both engine and integrated vehicle performance and stability. This new test technology was established in the MSFC Cold Flow Propulsion Test Complex to allow injection and measurement of scaled propellant flows and measurement of the resulting forces at multiple locations throughout the engine.

  13. Pre-Test Analysis Predictions for the Shell Buckling Knockdown Factor Checkout Tests - TA01 and TA02

    Science.gov (United States)

    Thornburgh, Robert P.; Hilburger, Mark W.

    2011-01-01

    This report summarizes the pre-test analysis predictions for the SBKF-P2-CYL-TA01 and SBKF-P2-CYL-TA02 shell buckling tests conducted at the Marshall Space Flight Center (MSFC) in support of the Shell Buckling Knockdown Factor (SBKF) Project, NASA Engineering and Safety Center (NESC) Assessment. The test article (TA) is an 8-foot-diameter aluminum-lithium (Al-Li) orthogrid cylindrical shell with similar design features as that of the proposed Ares-I and Ares-V barrel structures. In support of the testing effort, detailed structural analyses were conducted and the results were used to monitor the behavior of the TA during the testing. A summary of predicted results for each of the five load sequences is presented herein.

  14. GLL PPR INITIAL CHECKOUT RDR

    Data.gov (United States)

    National Aeronautics and Space Administration — added ARCHIVE_STATUS, ,This data set contains the RDR data for the Galileo Orbiter PPR instrument for the period corresponding to the initial turn-on and checkout of...

  15. Dry runs and machine check-out strategy

    OpenAIRE

    Albert, M; Giachino, R

    2014-01-01

    The paper describes the structure, organisation and strategies which will be applied to prepare the LHC for beam commissioning in early 2015 after its first long shutdown. Equipment dry runs, sector test preparation and final machine checkout, which constitute the ingredients for a smooth start of beam commissioning, will be explained.

  16. Design Assisted by Testing of Cold Formed Steel Trusses

    Directory of Open Access Journals (Sweden)

    Raul Zaharia

    2004-01-01

    Full Text Available The paper presents the experimental program developed in the Laboratory of Civil Engineering Faculty of the ”Politehnica” University of Timișoara, Romania, in order to establish the real behavior of bolted connections in cold formed steel trusses. First, the semi-rigid behavior of cold formed steel truss joints is demonstrated by means of test of typical T joints. A formula for the axial rigidity of single lap joint is determined, and, based on this formula, theoretical models are proposed for the rotational rigidity of cold formed steel truss bolted joints. In the third step of the experimental program, a cold formed steel truss is tested, in order to observe the structural behavior of joints and to validate the theoretical assumptions. A numerical analysis of the tested structure is also performed, and comparisons with the experimental results are given.

  17. GLL PPR INITIAL CHECKOUT R_EDR

    Data.gov (United States)

    National Aeronautics and Space Administration — added ARCHIVE_STATUS, ,This data set contains the R_EDR data for the Galileo Orbiter PPR instrument for the period corresponding to the initial turn-on and checkout...

  18. Testing THEMIS wave measurements against the cold plasma theory

    Science.gov (United States)

    Taubenschuss, Ulrich; Santolik, Ondrej; Le Contel, Olivier; Bonnell, John

    2016-04-01

    The THEMIS (Time History of Events and Macroscale Interactions during Substorms) mission records a multitude of electromagnetic waves inside Earth's magnetosphere and provides data in the form of high-resolution electric and magnetic waveforms. We use multi-component measurements of whistler mode waves and test them against the theory of wave propagation in a cold plasma. The measured ratio cB/E (c is speed of light in vacuum, B is magnetic wave amplitude, E is electric wave amplitude) is compared to the same quantity calculated from cold plasma theory over linearized Faraday's law. The aim of this study is to get estimates for measurement uncertainties, especially with regard to the electric field and the cold plasma density, as well as evaluating the validity of cold plasma theory inside Earth's radiation belts.

  19. The effect of different supermarket checkout workstations on trunk kinematics of checkout operators O efeito de diferentes modelos de checkout na cinemática de operadores de supermercado

    Directory of Open Access Journals (Sweden)

    André L. F. Rodacki

    2010-02-01

    Full Text Available OBJECTIVES: This study analyzed the effect of a standard and a modified checkout workstation during a simulated task on trunk postures of a supermarket checkout operator. METHODS: Eight participants performed a task involving grasping, scanning and depositing products, while 3D images of the trunk were collected. RESULTS: A number of kinematic changes were observed in trunk posture. A greater anterior flexion (3.0±1.2º and lateral bending during grasping (7.1±1.4º were found in the standard checkout workstation when compared to the modified model (p0.05. DISCUSSION: The modified checkout workstation provided less lateral bending of the trunk to grasp products (8.1º ± 2.8; p0.05, irrespective of the checkout workstations (p>0.05. The modified checkout workstation successfully reduced risk of injury in some aspects, particularly the problems associated with lateral bending of the trunk. Other studies are required to test whether such potential benefits are obtained on a daily basis. CONCLUSIONS: Supermarket checkout operators may be at high risk of occupational injury due to different workstation demands. Modifications to checkout workstation design are an attractive possibility to reduce postural stress and fatigue in checkout operators. Longitudinal studies are required to test whether changes observed in the present study are sustained in the long term.OBJETIVOS: Analisar o efeito de um modelo padrão e de um modificado de checkout durante uma tarefa simulada de um operador de caixa de supermercado. MÉTODOS: Oito participantes desempenharam uma tarefa envolvendo apanhar, ler e depositar produtos, enquanto imagens 3D do tronco foram coletadas. RESULTADOS: Um número de mudanças cinemáticas foram observadas na postura do tronco. Uma maior flexão anterior (3.0±1.2º e uma inclinação lateral durante o apanhar (7.1±1.4º foram encontradas no checkout padrão quando comparadas ao modelo modificado (p0.05. DISCUSSÃO: O checkout

  20. Design verification and cold-flow modeling test report

    Energy Technology Data Exchange (ETDEWEB)

    1993-07-01

    This report presents a compilation of the following three test reports prepared by TRW for Alaska Industrial Development and Export Authority (AIDEA) as part of the Healy Clean Coal Project, Phase 1 Design of the TRW Combustor and Auxiliary Systems, which is co-sponsored by the Department of Energy under the Clean Coal Technology 3 Program: (1) Design Verification Test Report, dated April 1993, (2) Combustor Cold Flow Model Report, dated August 28, 1992, (3) Coal Feed System Cold Flow Model Report, October 28, 1992. In this compilation, these three reports are included in one volume consisting of three parts, and TRW proprietary information has been excluded.

  1. Cold Regions - Environmental Testing of Grenade Launchers

    Science.gov (United States)

    2012-12-20

    considerations for temporary portable maintenance, and/or administrative facilities such as vans/expandable vans, trailers, and tents or tarps to support test...Digital Tipping Bucket ± 0.05 cm (0.02 in.) Solar Radiation Digital Pyranometer ± 14.90x10 –6 Volts (V)/watt/meter2 Fluid Viscosity Viscosity

  2. Cold Vacuum Drying Facility Stack Air Sampling System Qualification Tests

    Energy Technology Data Exchange (ETDEWEB)

    Glissmeyer, John A.

    2001-01-24

    This report documents tests that were conducted to verify that the air monitoring system for the Cold Vacuum Drying Facility ventilation exhaust stack meets the applicable regulatory criteria regarding the placement of the air sampling probe, sample transport, and stack flow measurement accuracy.

  3. Using IoT Device Technology in Spacecraft Checkout Systems

    Science.gov (United States)

    Plummer, Chris

    2015-09-01

    The Internet of Things (IoT) has become a common theme in both the technical and popular press in recent years because many of the enabling technologies that are required to make IoT a reality have now matured. Those technologies are revolutionising the way industrial systems and products are developed because they offer significant advantages over older technologies. This paper looks at how IoT device technology can be used in spacecraft checkout systems to achieve smaller, more capable, and more scalable solutions than are currently available. It covers the use of IoT device technology for classical spacecraft test systems as well as for hardware-in-the-loop simulation systems used to support spacecraft checkout.

  4. Cold Pressor Test as a Predictor of Hypertension

    Directory of Open Access Journals (Sweden)

    Paresh Roychowdhury

    2009-09-01

    Full Text Available Background: Early detection of proneness to hypertension may help an individual to lead a healthy life by altering the life style. Subjects having the predisposing factors of hypertension tend to show higher and prolonged responsiveness to blood pressure following stress.Methods: Normotensive, non-smoking healthy sedentary male students and staff of Nepal Medical College (n=50, age group 18-35 years participated in the study, conducted between May 2008 and June 2008. Participants with hypertensive parents, either or both, were considered volunteers from hypertensive families. The cold pressor test was carried out. The changes in blood pressure and heart rate among the volunteers of the hypertensive and normotensive families were compared using Student’s t-test.Results: In the present study, sympathetic stimulation exerted through the cold pressor test resulted in an elevation of blood pressure and heart rate in all the young male normotensive individuals. Blood pressure and heart rate returned to the baseline 5 minutes after the withdrawal of the stressor in the cases of the volunteers with no history of familial hypertension. On the other hand, the subjects whose parents, either or both, were reported to be hypertensive showed elevated diastolic blood pressure even 5 minutes after the withdrawal of the stressor.Conclusion: The present study revealed that the normotensive young male subjects who presented prolonged elevated diastolic pressure in response to sympathetic stimulation through the cold pressor test were prone to develop hypertension in the future.

  5. Rocket Assembly and Checkout Facility

    Data.gov (United States)

    Federal Laboratory Consortium — FUNCTION: Integrates, tests, and calibrates scientific instruments flown on sounding rocket payloads. The scientific instruments are assembled on an optical bench;...

  6. Cold Regions Test of Tracked and Wheeled Vehicles

    Science.gov (United States)

    2015-12-11

    being instructed to start, the subjects have one minute to write each word one time and study the list. The list is then immediately turned upside...minute to write down as many of the original twelve words as they can remember. All subjects are given the same list of words for a given test...long cold spell has chilled the ground. Other causes are automobile exhaust or the compressed remnants of a snowfall. c. Black ice (sometimes known

  7. A new Friction and Lubrication Test for Cold Forging

    DEFF Research Database (Denmark)

    Bay, Niels; Wibom, Ole; Aalborg Nielsen, J

    1995-01-01

    This paper presents a new friction and lubrication test for cold forging. The test allows controlled variation of the surface expansion in the range 0-2000%, the tool temperature in the range 20-270°C and the sliding length between 0 and infinite. Friction is decreasing with increasing temperature...... in the range 30-150°C. Above this temperature range friction increases. As regards lubricant performance Lubrication Limit Curves (LLC) are plotted in a sliding length-surface enlargement diagram with the tool temperature as a parameter. Larger tool temperature implies lower acceptable surface expansion...

  8. Alternate Reductant Cold Cap Evaluation Furnace Phase II Testing

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, F. C. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Stone, M. E. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Miller, D. H. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2014-09-03

    Savannah River Remediation (SRR) conducted a Systems Engineering Evaluation (SEE) to determine the optimum alternate reductant flowsheet for the Defense Waste Processing Facility (DWPF). Specifically, two proposed flowsheets (nitric–formic–glycolic and nitric–formic–sugar) were evaluated based upon results from preliminary testing. Comparison of the two flowsheets among evaluation criteria indicated a preference towards the nitric–formic–glycolic flowsheet. Further research and development of this flowsheet eliminated the formic acid, and as a result, the nitric–glycolic flowsheet was recommended for further testing. Based on the development of a roadmap for the nitric–glycolic acid flowsheet, Waste Solidification Engineering (WS-E) issued a Technical Task Request (TTR) to address flammability issues that may impact the implementation of this flowsheet. Melter testing was requested in order to define the DWPF flammability envelope for the nitric-glycolic acid flowsheet. The Savannah River National Laboratory (SRNL) Cold Cap Evaluation Furnace (CEF), a 1/12th scale DWPF melter, was selected by the SRR Alternate Reductant project team as the melter platform for this testing. The overall scope was divided into the following sub-tasks as discussed in the Task Technical and Quality Assurance Plan (TTQAP): Phase I - A nitric–formic acid flowsheet melter test (unbubbled) to baseline the CEF cold cap and vapor space data to the benchmark melter flammability models; Phase II - A nitric–glycolic acid flowsheet melter test (unbubbled and bubbled) to: Define new cold cap reactions and global kinetic parameters in support of the melter flammability model development; Quantify off-gas surging potential of the feed; Characterize off-gas condensate for complete organic and inorganic carbon species. After charging the CEF with cullet from Phase I CEF testing, the melter was slurry-fed with glycolic flowsheet based SB6-Frit 418 melter feed at 36% waste

  9. The Cold Dark Matter Search test stand warm electronics card

    Energy Technology Data Exchange (ETDEWEB)

    Hines, Bruce; /Colorado U., Denver; Hansen, Sten; /Fermilab; Huber, Martin; /Colorado U., Denver; Kiper, Terry; /Fermilab; Rau, Wolfgang; /Queen' s U., Kingston; Saab, Tarek; /Florida U.; Seitz, Dennis; Sundqvist, Kyle; /UC, Berkeley; Mandic, Vuk; /Minnesota U.

    2010-11-01

    A card which does the signal processing for four SQUID amplifiers and two charge sensitive channels is described. The card performs the same functions as is presently done with two custom 9U x 280mm Eurocard modules, a commercial multi-channel VME digitizer, a PCI to GPIB interface, a PCI to VME interface and a custom built linear power supply. By integrating these functions onto a single card and using the power over Ethernet standard, the infrastructure requirements for instrumenting a Cold Dark Matter Search (CDMS) detector test stand are significantly reduced.

  10. ALTERNATE REDUCTANT COLD CAP EVALUATION FURNACE PHASE I TESTING

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, F.; Miller, D.; Zamecnik, J.; Lambert, D.

    2014-04-22

    Savannah River Remediation (SRR) conducted a Systems Engineering Evaluation (SEE) to determine the optimum alternate reductant flowsheet for the Defense Waste Processing Facility (DWPF). Specifically, two proposed flowsheets (nitric–formic–glycolic and nitric–formic–sugar) were evaluated based upon results from preliminary testing. Comparison of the two flowsheets among evaluation criteria indicated a preference towards the nitric–formic–glycolic flowsheet. Further evaluation of this flowsheet eliminated the formic acid1, and as a result, the nitric–glycolic flowsheet was recommended for further testing. Based on the development of a roadmap for the nitric–glycolic acid flowsheet, Waste Solidification Engineering (WS-E) issued a Technical Task Request (TTR) to address flammability issues that may impact the implementation of this flowsheet. Melter testing was requested in order to define the DWPF flammability envelope for the nitric glycolic acid flowsheet. The Savannah River National Laboratory (SRNL) Cold Cap Evaluation Furnace (CEF), a 1/12th scale DWPF melter, was selected by the SRR Alternate Reductant project team as the melter platform for this testing. The overall scope was divided into the following sub-tasks as discussed in the Task Technical and Quality Assurance Plan (TTQAP): Phase I - A nitric–formic acid flowsheet melter test (unbubbled) to baseline the Cold Cap Evaluation Furnace (CEF) cold cap and vapor space data to the benchmark melter flammability models Phase II - A nitric–glycolic acid flowsheet melter test (unbubbled and bubbled) to: o Define new cold cap reactions and global kinetic parameters for the melter flammability models o Quantify off-gas surging potential of the feed o Characterize off-gas condensate for complete organic and inorganic carbon species Prior to startup, a number of improvements and modifications were made to the CEF, including addition of cameras, vessel support temperature measurement, and a heating

  11. Cold Test and Performance Evaluation of Prototype Cryoline-X

    Science.gov (United States)

    Shah, N.; Choukekar, K.; Kapoor, H.; Muralidhara, S.; Garg, A.; Kumar, U.; Jadon, M.; Dash, B.; Bhattachrya, R.; Badgujar, S.; Billot, V.; Bravais, P.; Cadeau, P.

    2017-12-01

    The multi-process pipe vacuum jacketed cryolines for the ITER project are probably world’s most complex cryolines in terms of layout, load cases, quality, safety and regulatory requirements. As a risk mitigation plan, design, manufacturing and testing of prototype cryoline (PTCL) was planned before the approval of final design of ITER cryolines. The 29 meter long PTCL consist of 6 process pipes encased by thermal shield inside Outer Vacuum Jacket of DN 600 size and carries cold helium at 4.5 K and 80 K. The global heat load limit was defined as 1.2 W/m at 4.5 K and 4.5 W/m at 80 K. The PTCL-X (PTCL for Group-X cryolines) was specified in detail by ITER-India and designed as well as manufactured by Air Liquide. PTCL-X was installed and tested at cryogenic temperature at ITER-India Cryogenic Laboratory in 2016. The heat load at 4.5 K and 80 K, estimated using enthalpy difference method, was found to be approximately 0.8 W/m at 4.5 K, 4.2 W/m at 80 K, which is well within the defined limits. Thermal shield temperature profile was also found to be satisfactory. Paper summarizes the cold test results of PTCL-X

  12. Fabrication and cold test of dielectric assist accelerating structure

    Science.gov (United States)

    Satoh, D.; Yoshida, M.; Hayashizaki, N.

    2017-09-01

    We present the detailed description of a successful design and cold testing of the dielectric assist accelerating (DAA) structure. The DAA structure consists of ultralow-loss dielectric cylinders and disks with irises which are periodically arranged in a metallic enclosure. The advantage of the DAA structure is that it has an extremely high quality factor and a very high shunt impedance at room temperature since the electromagnetic field distribution of accelerating mode can be controlled by dielectric parts so that the wall loss on the metallic surface is greatly reduced. A prototype of the five-cell DAA structure was designed and built at C-band (5.712 GHz), and cold tested. Three types of dielectric cell structure, "regular," "end," and "hybrid" dielectric cells, are fabricated by sintering high-purity magnesia. The prototype was assembled by stacking these cells in the hollow copper cylinder, whose two ends are closed by copper plates. The resonant frequency of the prototype was tuned to the desired frequency by machining only end copper plates. The unloaded quality factor of the accelerating mode was measured at 119,314 and the shunt impedance per unit length of the prototype was estimated from the experimental results of the bead pull measurement as Zsh=617 M Ω /m , which were within 2 percent of the design values. The field distribution of accelerating mode was also measured by the bead pull method, and its results agreed well with simulation results.

  13. Results from the Cold Atom Laboratory's ground test bed

    Science.gov (United States)

    Elliott, Ethan; CAL Team

    2017-04-01

    We describe validation and development of critical technologies in the Cold Atom Laboratory's (CAL) ground test bed, including the demonstration of the first microwave evaporation and generation of dual-species quantum gas mixtures on an atom chip. CAL is a multi-user facility developed by NASA's Jet Propulsion Laboratory (JPL) to provide the first persistent quantum gas platform in the microgravity environment of space. The CAL instrument will be operated aboard the International Space Station (ISS) and utilize a compact atom chip trap loaded from a dual-species magneto optical trap of rubidium and potassium. In the unique environment of microgravity, the confining potentials necessary to the process of cooling atoms can be arbitrarily relaxed, enabling production of gases down to pikoKelvin temperatures and ultra-low densities. Complete removal of the confining potential allows for ultracold clouds that can float virtually fixed relative to the CAL apparatus. This new parameter regime enables ultracold atom research with broad applications in fundamental physics and inertial sensing. Results from the Cold Atom Laboratory's ground testbed.

  14. SHEAR STRENGTH MEASURING EQUIPMENT EVALUATION AT THE COLD TEST FACILITY

    Energy Technology Data Exchange (ETDEWEB)

    MEACHAM JE

    2009-09-09

    Retrievals under current criteria require that approximately 2,000,000 gallons of double-shell tank (DST) waste storage space not be used to prevent creating new tanks that might be susceptible to buoyant displacement gas release events (BDGRE). New criteria are being evaluated, based on actual sludge properties, to potentially show that sludge wastes do not exhibit the same BDGRE risk. Implementation of the new criteria requires measurement of in situ waste shear strength. Cone penetrometers were judged the best equipment for measuring in situ shear strength and an A.P. van den berg Hyson 100 kN Light Weight Cone Penetrometer (CPT) was selected for evaluation. The CPT was procured and then evaluated at the Hanford Site Cold Test Facility. Evaluation demonstrated that the equipment with minor modification was suitable for use in Tank Farms.

  15. Fabrication and cold test of dielectric assist accelerating structure

    Directory of Open Access Journals (Sweden)

    D. Satoh

    2017-09-01

    Full Text Available We present the detailed description of a successful design and cold testing of the dielectric assist accelerating (DAA structure. The DAA structure consists of ultralow-loss dielectric cylinders and disks with irises which are periodically arranged in a metallic enclosure. The advantage of the DAA structure is that it has an extremely high quality factor and a very high shunt impedance at room temperature since the electromagnetic field distribution of accelerating mode can be controlled by dielectric parts so that the wall loss on the metallic surface is greatly reduced. A prototype of the five-cell DAA structure was designed and built at C-band (5.712 GHz, and cold tested. Three types of dielectric cell structure, “regular,” “end,” and “hybrid” dielectric cells, are fabricated by sintering high-purity magnesia. The prototype was assembled by stacking these cells in the hollow copper cylinder, whose two ends are closed by copper plates. The resonant frequency of the prototype was tuned to the desired frequency by machining only end copper plates. The unloaded quality factor of the accelerating mode was measured at 119,314 and the shunt impedance per unit length of the prototype was estimated from the experimental results of the bead pull measurement as Z_{sh}=617  MΩ/m, which were within 2 percent of the design values. The field distribution of accelerating mode was also measured by the bead pull method, and its results agreed well with simulation results.

  16. Advanced Vehicle Testing Activity Cold Weather On-road Testing of the Chevrolet Volt

    Energy Technology Data Exchange (ETDEWEB)

    Smart, John [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2015-03-01

    This report details cold weather on-road testing of a Chevrolet Volt. It quantifies changes in efficiency and electric range as ambient temperature changes. It will be published to INL's AVTA website as an INL technical report and will be accessible to the general public.

  17. RELAP4/MOD5: a computer program for transient thermal-hydraulic analysis of nuclear reactors and related systems. User's manual. Volume III. Checkout applications. [PWR and BWR

    Energy Technology Data Exchange (ETDEWEB)

    Obenchain, C. F.; Ramsthaler, J. H.; Eales, E. P.; Charlton, T. R.; Childs, F. W.; Giles, M. M.; Good, E. G.; Gruen, G. E.; Guttman, J.; Johnsen, G. W.; Katsma, K. R.; Keeler, C. D.; Lawford, T. W.; Mohr, C. M.; Singer, G. L.; Townsend, W. C.

    1976-09-01

    Checkout problems presented include the following: PWR large cold leg break; PWR small cold leg break; PWR intermediate sized cold leg break; BWR large recirculation line break; BWR small recirculation line break; INEL Semiscale small cold leg break; INEL LOFT large cold leg break and INEL Semiscale large cold leg break. Also included is Update 2 of the RELAP 4/M0D5 code.

  18. Cold pressor test using strain-gauge plethysmography.

    Science.gov (United States)

    Feliciani, Giacomo; Peron, Cristiano; La Rocca, Augusto; Scuppa, Maria Francesca; Malavolta, Andrea; Bianchini, David; Corazza, Ivan; Zannoli, Romano

    2016-09-01

    This laboratory activity is designed to teach students how to measure forearm muscle blood flow (FBF) to describe the mechanisms of peripheral blood flow thermal regulation in healthy subjects. The cold pressor test (CPT) is the clinical procedure used in the experiment to induce arterial vasoconstriction. Strain-gauge plethysmography is applied on the patient's forearm to noninvasive monitor vasoconstriction effects on local blood perfusion and physiological parameters such as blood pressure (BP) and heart rate (HR). Patients with an altered peripheral vascular resistance (e.g., in hypertension) have different responses to the CPT from healthy subjects. To date, experimental evidence remains unexplained, as we do not know if the BP and HR increase is caused by a decrease in flow rate or an increase in peripheral vascular resistance during the test. To clarify this situation, we have to quantify the parameter we assume is being conditioned by the regulatory physiological intervention, i.e., peripheral vascular resistance. Peripheral vascular resistance quantification can be calculated as the ratio between muscle flow and mean arterial pressure. Students will learn how to apply the instrumental procedure to collect and analyze data before, during, and after the CPT and to describe the physiological responses of the peripheral vascular system to external stressors. They will also learn how to distinguish healthy from pathological responses on the basis of how sympathetic nervous system reactions influence the biomechanics of peripheral vessels. Copyright © 2016 The American Physiological Society.

  19. ESA's Mars Express first check-out nearly complete

    Science.gov (United States)

    2003-07-01

    This testing phase is standard for all spacecraft on the way to their destination. Known as commissioning, it began in 3 weeks after the launch. During this time, ground controllers sent signals to each of the orbiter's seven instruments to switch them on them and verify their health status. As well as commissioning the instruments, the ground controllers also tested each of the spacecraft's subsystems. There was a thrilling moment when one of the on-board computer memory units, known as the Solid State Mass Memory (SSMM), seemed to not respond properly during the instruments check-out. Good progress has been made on this issue in the last few days: a test involving all instruments was completed successfully by recording and recovering the data through the SSMM. Unfortunately, during the commissioning of the power subsystem, ground engineers recorded an interconnection problem between the solar arrays and the power conditioning unit on board the spacecraft. This means approximately 70% of the power generated by the solar arrays is available for the satellite and its payload to use. This anomaly has no effect on the state of the spacecraft and has no impact on the mission during the whole trip to Mars, including the orbit insertion phase once at destination. Despite this, the experts analysing the anomaly believe that even with this power shortage, the nominal Mars observation mission will be achievable. However satellite payload operations may have to be reviewed for certain short periods of the mission. Ground engineers are now preparing for the last of the payload's tests: the Beagle-2 lander will undergo its check-out on 4-5 July 2003. The experts are looking confidently to it."In fact," says Rudolf Schmidt, Mars Express Project Manager,"overall, the spacecraft is in good shape. We are simply getting to know its personality."

  20. Engineering, Manufacture and Preliminary Testing of the ITER Toroidal Field (TF) Magnet Helium Cold Circulator

    Science.gov (United States)

    Rista, P. E. C.; Shull, J.; Sargent, S.

    2015-12-01

    The ITER cryodistribution system provides the supercritical Helium (SHe) forced flow cooling to the magnet system using cold circulators. The cold circulators are located in each of five separate auxiliary cold boxes planned for use in the facility. Barber-Nichols Inc. has been awarded a contract from ITER-India for engineering, manufacture and testing of the Toroidal Field (TF) Magnet Helium Cold Circulator. The cold circulator will be extensively tested at Barber-Nichols’ facility prior to delivery for qualification testing at the Japan Atomic Energy Agency's (JAEA) test facility at Naka, Japan. The TF Cold Circulator integrates features and technical requirements which Barber-Nichols has utilized when supplying helium cold circulators worldwide over a period of 35 years. Features include a vacuum-jacketed hermetically sealed design with a very low helium leak rate, a heat shield for use with both nitrogen & helium cold sources, a broad operating range with a guaranteed isentropic efficiency over 70%, and impeller design features for high efficiency. The cold circulator will be designed to meet MTBM of 17,500 hours and MTBF of 36,000 hours. Vibration and speed monitoring are integrated into a compact package on the rotating assembly with operation and health monitoring in a multi-drop PROFIBUS communication environment using an electrical cabinet with critical features and full local and network PLC interface and control. For the testing in Japan and eventual installation in Europe, the cold circulator must be certified to the Japanese High Pressure Gas Safety Act (JHPGSA) and CE marked in compliance with the European Pressure Equipment Directive (PED) including Essential Safety Requirements (ESR). The test methodology utilized at Barber-Nichols’ facility and the resulting test data, validating the high efficiency of the TF Cold Circulator across a broad operating range, are important features of this paper.

  1. Association of Type D personality with the autonomic and hemodynamic response to the cold pressor test

    NARCIS (Netherlands)

    Kupper, N.; Pelle, A.J.M.; Denollet, J.

    2013-01-01

    Mechanisms relating Type D personality to poor health are largely unknown, with autonomic nervous system function being a candidate. This study examined the physiologic response to cold stress. Undergraduates (N = 101, 84% female) underwent a cold pressor test. An electrocardiogram, impedance

  2. Traveling-Wave Tube Cold-Test Circuit Optimization Using CST MICROWAVE STUDIO

    Science.gov (United States)

    Chevalier, Christine T.; Kory, Carol L.; Wilson, Jeffrey D.; Wintucky, Edwin G.; Dayton, James A., Jr.

    2003-01-01

    The internal optimizer of CST MICROWAVE STUDIO (MWS) was used along with an application-specific Visual Basic for Applications (VBA) script to develop a method to optimize traveling-wave tube (TWT) cold-test circuit performance. The optimization procedure allows simultaneous optimization of circuit specifications including on-axis interaction impedance, bandwidth or geometric limitations. The application of Microwave Studio to TWT cold-test circuit optimization is described.

  3. Hanford spent nuclear fuel cold vacuum drying proof of performance test procedure

    Energy Technology Data Exchange (ETDEWEB)

    McCracken, K.J.

    1998-06-10

    This document provides the test procedure for cold testing of the first article skids for the Cold Vacuum Drying (CVD) process at the Facility. The primary objective of this testing is to confirm design choices and provide data for the initial start-up parameters for the process. The current scope of testing in this document includes design verification, drying cycle determination equipment performance testing of the CVD process and MCC components, heat up and cool-down cycle determination, and thermal model validation.

  4. Nasal provocation test using allergen extract versus cold dry air provocation test: which and when?

    Science.gov (United States)

    Kim, Young Hyo; Jang, Tae Young

    2013-01-01

    Nasal provocation tests (NPTs) are useful for evaluation of patients with allergic rhinitis. The cold dry air (CDA) provocation test is useful for evaluation of patients with nonspecific nasal hyperreactivity (NHR). This study aimed to determine whether the NPT or CDA provocation would be more useful for patients with different clinical pictures. We evaluated changes in nasal symptoms (visual analog scale [VAS]) and acoustic parameters after NPT or CDA provocation in healthy volunteers (group A, n = 27), patients with allergic rhinitis (group B, n = 20), and subjects with nonallergic rhinitis (group C, n = 26). According to their subjective cold hyperresponsiveness (SCH), we compared changes in VAS and acoustic parameters after each protocol. The correlation between results of the skin-prick test (SPT) and changes in VAS after each protocol was analyzed. Finally, we performed an analysis of correlation between NPT and CDA provocation. After NPT, group B showed a larger change in VAS for rhinorrhea, sneezing, and itching (p < 0.01). After CDA challenge, the change in VAS for nasal obstruction was larger in group C (p < 0.05). Changes in acoustic parameters were larger in groups B and C after NPT (p < 0.01). After CDA challenge, the SCH(+) group (n = 49) showed a larger decrease of acoustic parameters than the SCH(-) group (n = 24; p < 0.01). Significant correlation was observed between the size of SPT and degree of change in VAS after NPT. No significant correlation was observed between NPT and CDA. CDA could be an adjunct tool for evaluating NHR in patients with self-reported SCH.

  5. Cold-end Subsystem Testing for the Fission Power System Technology Demonstration Unit

    Science.gov (United States)

    Briggs, Maxwell; Gibson, Marc; Ellis, David; Sanzi, James

    2013-01-01

    The Fission Power System (FPS) Technology Demonstration Unit (TDU) consists of a pumped sodium-potassium (NaK) loop that provides heat to a Stirling Power Conversion Unit (PCU), which converts some of that heat into electricity and rejects the waste heat to a pumped water loop. Each of the TDU subsystems is being tested independently prior to full system testing at the NASA Glenn Research Center. The pumped NaK loop is being tested at NASA Marshall Space Flight Center; the Stirling PCU and electrical controller are being tested by Sunpower Inc.; and the pumped water loop is being tested at Glenn. This paper describes cold-end subsystem setup and testing at Glenn. The TDU cold end has been assembled in Vacuum Facility 6 (VF 6) at Glenn, the same chamber that will be used for TDU testing. Cold-end testing in VF 6 will demonstrate functionality; validated cold-end fill, drain, and emergency backup systems; and generated pump performance and system pressure drop data used to validate models. In addition, a low-cost proof-of concept radiator has been built and tested at Glenn, validating the design and demonstrating the feasibility of using low-cost metal radiators as an alternative to high-cost composite radiators in an end-to-end TDU test.

  6. Simulative Testing of Friction and Lubrication in Cold Forging of Steel and Aluminum

    DEFF Research Database (Denmark)

    Ceron, Ermanno; Bay, Niels; Aida, Tetsuo

    2012-01-01

    A new, simulative test of friction and lubrication in cold forging is developed by the authors. The test is based on a backward can extrusion process in which the workpiece rotates relatively to the conical punch. An analytical model is presented determining the friction stress from the measured ...

  7. Thermovision Analysis Changes of Human Hand Surface Temperature in Cold Pressor Test.

    Science.gov (United States)

    Chwałczyńska, Agnieszka; Gruszka, Katarzyna; Całkosiński, Ireneusz; Sobiech, Krzysztof A

    2015-01-01

    The cold pressor test (CTP) as a diagnostic method of the circulatory system reactivity may be a basis for the qualification for thermal stimulation therapy. The aim of the work was a thermovisual assessment of the reaction to the Hines and Brown cold pressor test. A group of 30 healthy men in the age of 23.5 ± 0.8 years were examined. The average weight of the examinees was 78.4 ± 9.2 kg, their height 180.7 ± 5.9 cms, and BMI 23.9 ± 2.2 kg/m(2). A thermovisual picture of a tested and not tested hand of all the subjects was taken before and after the cold pressor test. Under the influence of cold water the surface temperature of a tested hand has decreased in a statistically significant way by 8.3°C on average, which is 29% of the temperature before the test, whilst the temperature of an untested hand dropped by 0.67°C. The decreases of temperature were not even and there was a statistically significant difference between the dorsal and palmar side of the hand. The correlation between the changes of systolic blood pressure and the hand surface temperature before and after CTP was observed.

  8. Acid Pit Stabilization Project (Volume 1 - Cold Testing) and (Volume 2 - Hot Testing)

    Energy Technology Data Exchange (ETDEWEB)

    G. G. Loomis (INEEL); A. P. Zdinak (MSE); M. A. Ewanic (MSE); J. J. Jessmore (INEEL)

    1998-01-01

    During the summer and fall of Fiscal Year 1997, a Comprehensive Environmental Response, Compensation, and Liability Act (CERCLA) Treatability Study was performed at the Idaho National Engineering and Environmental Laboratory. The study involved subsurface stabilization of a mixed waste contaminated soil site called the Acid Pit. This study represents the culmination of a successful technology development effort that spanned Fiscal Years 1994-1996. Research and development of the in situ grout stabilization technique was conducted. Hardware and implementation techniques are currently documented in a patent pending with the United States Patent and Trademark Office. The stabilization technique involved using jet grouting of an innovative grouting material to form a monolith out of the contamination zone. The monolith simultaneously provides a barrier to further contaminant migration and closes voids in the soil structure against further subsidence. This is accomplished by chemical incorporation of contaminants into less soluble species and achieving a general reduction in hydraulic conductivity within the monolith. The grout used for this study was TECT-HG, a relatively dense iron oxide-based cementitious grout. The treatability study involved cold testing followed by in situ stabilization of the Acid Pit. Volume 1 of this report discusses cold testing, performed as part of a ''Management Readiness Assessment'' in preparation for going hot. Volume 2 discusses the results of the hot Acid Pit Stabilization phase of this project. Drilling equipment was specifically rigged to reduce the spread of contamination, and all grouting was performed under a concrete block containing void space to absorb any grout returns. Data evaluation included examination of implementability of the grouting process and an evaluation of the contaminant spread during grouting. Following curing of the stabilized pit, cores were obtained and evaluated for toxicity

  9. Cold Regions - Environmental Testing of Individual Soldier Clothing

    Science.gov (United States)

    2011-10-17

    portable maintenance, and/or administrative facilities such as vans/expandable vans, trailers, and tents or tarps to support test operations should be...Precipitation - summer Digital tipping bucket ± 0.05 cm (0.02 in.) Solar radiation Digital pyranometer ± 14.90x10-6 volt (V)/watt meter2 Snow and soil

  10. Cold Regions - Environmental Testing of Individual Soldier Equipment

    Science.gov (United States)

    2011-10-17

    strong seasonality with distinct changes in insolation ( solar radiation energy), frozen atmospheric moisture, frozen ground, and freeze/thaw of water...strong seasonality with distinct changes in insolation ( solar radiation energy), frozen atmospheric moisture, frozen ground, and freeze/thaw of water...portable maintenance, and/or administrative facilities such as vans/expandable vans, trailers, and tents or tarps to support test operations. 2.2

  11. First test of cold edgeless silicon microstrip detectors

    Science.gov (United States)

    Avati, V.; Boccone, V.; Borer, K.; Bozzo, M.; Capra, R.; Casagrande, L.; Eggert, K.; Heijne, E.; Klauke, S.; Li, Z.; Mäki, T.; Morelli, A.; Oljemark, F.; Palmieri, V. G.; Perea-Solano, B.; Tapprogge, S.

    2004-02-01

    Silicon microstrip detectors will provide the forward tracking in the TOTEM experiment at the LHC. To allow efficient tracking closest to the beam (≈1 mm) these detectors should be sensitive up to their physical edge (i.e. edgeless). Edgeless (without guard rings) microstrip planar detectors can be operated at cryogenic temperatures (about 130° K) where leakage currents due to the active edge are drastically reduced. A silicon microstrip prototype, cut perpendicular to the strips, has been tested with a pion beam at CERN to study its efficiency close to the edge by using reference tracks from a simple silicon telescope. Results indicate that the detector measures tracks with good efficiency up to the physical edge of the silicon.

  12. First test of cold edgeless silicon microstrip detectors

    CERN Document Server

    Avati, V; Borer, K; Bozzo, M; Capra, R; Casagrande, L; Eggert, Karsten; Heijne, Erik H M; Klauke, S; Li, Z; Mäki, T; Morelli, A; Oljemark, F; Palmieri, V G; Perea-Solano, B; Tapprogge, Stefan

    2004-01-01

    Silicon microstrip detectors will provide the forward tracking in the TOTEM experiment at the LHC. To allow efficient tracking closest to the beam ( approximately equals 1 mm) these detectors should be sensitive up to their physical edge (i.e. edgeless). Edgeless (without guard rings) microstrip planar detectors can be operated at cryogenic temperatures (about 130 degree K) where leakage currents due to the active edge are drastically reduced. A silicon microstrip prototype, cut perpendicular to the strips, has been tested with a pion beam at CERN to study its efficiency close to the edge by using reference tracks from a simple silicon telescope. Results indicate that the detector measures tracks with good efficiency up to the physical edge of the silicon.

  13. First test of cold edgeless silicon microstrip detectors

    Energy Technology Data Exchange (ETDEWEB)

    Avati, V.; Boccone, V.; Borer, K.; Bozzo, M. E-mail: marco.bozzo@cern.ch; Capra, R.; Casagrande, L.; Eggert, K.; Heijne, E.; Klauke, S.; Li, Z.; Maeki, T.; Morelli, A.; Oljemark, F.; Palmieri, V.G.; Perea-Solano, B.; Tapprogge, S

    2004-02-01

    Silicon microstrip detectors will provide the forward tracking in the TOTEM experiment at the LHC. To allow efficient tracking closest to the beam ({approx}1 mm) these detectors should be sensitive up to their physical edge (i.e. edgeless). Edgeless (without guard rings) microstrip planar detectors can be operated at cryogenic temperatures (about 130 deg. K) where leakage currents due to the active edge are drastically reduced. A silicon microstrip prototype, cut perpendicular to the strips, has been tested with a pion beam at CERN to study its efficiency close to the edge by using reference tracks from a simple silicon telescope. Results indicate that the detector measures tracks with good efficiency up to the physical edge of the silicon.

  14. Stability of the Horizontal Curvature of the LHC Cryodipoles During Cold Tests

    CERN Document Server

    Cano, E D Fernandez; García-Pérez, J; Jeanneret, Jean Bernard; Poncet, A; Seyvet, F; Tovar-Gonzalez, A; Wildner, E; IEEE Trans. Nucl. Sci.

    2006-01-01

    The LHC will be composed of 1232 horizontally curved, 15 meter long, superconducting dipole magnets cooled at 1.9 K. They are supported within their vacuum vessel by three Glass Fiber Reinforced Epoxy (GFRE) support posts. Each cryodipole is individually cold tested at CERN before its installation and interconnection in the LHC 27 km circumference tunnel. As the magnet geometry under cryogenic operation is extremely important for the LHC machine aperture, a new method has been developed at CERN in order to monitor the magnet curvature change between warm and cold states. It enabled us to conclude that there is no permanent horizontal curvature change of the LHC dipole magnet between warm and cold states, although a systematic horizontal transient deformation during cool-down was detected. This deformation generates loads in the dipole supporting system; further investigation permitted us to infer this behavior to the asymmetric thermal contraction of the rigid magnet thermal shield during cool-down. Controlli...

  15. Finalize field testing of cold climate heat pump (CCHP) based on tandem vapor injection compressors

    Energy Technology Data Exchange (ETDEWEB)

    Shen, Bo [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Baxter, Van D. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Abdelaziz, Omar [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Rice, C. Keith [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2017-03-01

    This report describes the system diagram and control algorithm of a prototype air-source cold climate heat pump (CCHP) using tandem vapor injection (VI) compressors. The prototype was installed in Fairbanks, Alaska and underwent field testing starting in 09/2016. The field testing results of the past six months, including compressor run time fractions, measured COPs and heating capacities, etc., are presented as a function of the ambient temperature. Two lessons learned are also reported.

  16. ANN modeling of cold cranking test for sealed lead-acid batteries

    Science.gov (United States)

    Karami, Hassan; Karimi, Mohammad Ali; Mahdipour, Maryam

    A cold cranking test for 17 sealed lead-acid batteries with grids of lead-calcium alloy at -18 °C was performed at different discharge currents. Time-voltage behavior of the batteries during 10 s discharge, voltage values at discharge times of 30, 60 and 90 s, and time of discharge to reach a final voltage of 6 V are critical points in the cold cranking test. These were modeled by artificial neural networks in MATLAB 7 media. Nine discharge currents were used for the training set, five discharge currents for the prediction set and three discharge currents for the validation set. Maximum prediction errors in the modeling of the time-voltage behavior during a 10 s discharge (model 1), the voltage of critical points of 30, 60, 90 s (model 2) and the time to reach a final voltage of 6 V (model 3) were under 3.1%, 3.3%, and 3.5%, respectively for each model. The results obtained showed that the models can be used in the battery industry for the prediction of the cold cranking behavior of lead-acid batteries at high discharge currents based on experimental cold cranking data at low discharge currents without the use of expensive and complex instruments. A file (EXE file) based on the model obtained by WinNN 32 was prepared to enable inexpert operators in the lead-acid battery industry to use the method.

  17. Handling Ibuprofen increases pain tolerance and decreases perceived pain intensity in a cold pressor test.

    Science.gov (United States)

    Rutchick, Abraham M; Slepian, Michael L

    2013-01-01

    Pain contributes to health care costs, missed work and school, and lower quality of life. Extant research on psychological interventions for pain has focused primarily on developing skills that individuals can apply to manage their pain. Rather than examining internal factors that influence pain tolerance (e.g., pain management skills), the current work examines factors external to an individual that can increase pain tolerance. Specifically, the current study examined the nonconscious influence of exposure to meaningful objects on the perception of pain. Participants (N = 54) completed a cold pressor test, examined either ibuprofen or a control object, then completed another cold pressor test. In the second test, participants who previously examined ibuprofen reported experiencing less intense pain and tolerated immersion longer (relative to baseline) than those who examined the control object. Theoretical and applied implications of these findings are discussed.

  18. Handling Ibuprofen increases pain tolerance and decreases perceived pain intensity in a cold pressor test.

    Directory of Open Access Journals (Sweden)

    Abraham M Rutchick

    Full Text Available Pain contributes to health care costs, missed work and school, and lower quality of life. Extant research on psychological interventions for pain has focused primarily on developing skills that individuals can apply to manage their pain. Rather than examining internal factors that influence pain tolerance (e.g., pain management skills, the current work examines factors external to an individual that can increase pain tolerance. Specifically, the current study examined the nonconscious influence of exposure to meaningful objects on the perception of pain. Participants (N = 54 completed a cold pressor test, examined either ibuprofen or a control object, then completed another cold pressor test. In the second test, participants who previously examined ibuprofen reported experiencing less intense pain and tolerated immersion longer (relative to baseline than those who examined the control object. Theoretical and applied implications of these findings are discussed.

  19. An Overview of SM18 Cold Test Operation and a Way Forward

    CERN Document Server

    Allen, D; Hemelsoet, G H; Henriksen, J; Mazars, J; Niquille, C; Ottaviani, J; Priestnall, K; Vadillo, I; CERN. Geneva. AB Department

    2003-01-01

    The following document is a collection of observations and improvements that we have collected and collated. We are 9 people from PS and SL Division staff. (representing significant & broad work experience from PS & PSB machines Accelerator operation, SL Experimental physics North Area experience in beam line operation & Safety, SPS &LEP operation experience and several years of experience in RF hardware & operation in SL Division). We have participated in the SM18 cold tests operation since 4 November 2002 for a period of 4 weeks*, organized by V. Chohan, LHC Division, who is our supervisor for working on magnet cold tests. This document is categorized in 3 broad areas, for each of which a single person acted as a 'rapporteur' to put it all together. The 3 areas of immediate concern are: 1. Safety 2. Work And Procedures 3. Environment & Control Room.

  20. Cold Noise Testing of a Microseismometer for Planetary and Terrestrial Applications

    Science.gov (United States)

    Warren, T.; Pike, W. T.; Calcutt, S. B.; Bowles, N. E.; Temple, J.

    2016-12-01

    As part of the seismic payload for the Insight mission to Mars, a three axis set of microseismometers, known as SP, have been successfully integrated into the seismometer package. A set of performance tests on each flight sensor has been performed at the University of Oxford prior to integration. These tests demonstrate the minimum noise performance of the sensor is below 0.5ng/rtHz over a wide range of tilt angles at room temperature. Recently a flight spare sensor has been used to show the minimum noise performance is still below 0.5ng/rtHz over the range of expected temperatures on the Martian surface (from the expected Mars minimum of -60C to a maximum of +60C). Direct measurements of cold noise performance are difficult because of seismic noise from the cooling system, however a novel cold noise setup has been developed that allows for the direct measurement of performance at low temperatures.

  1. Simulations and cold-test results of a prototype plane wave transformer linac structure

    Directory of Open Access Journals (Sweden)

    Arvind Kumar

    2002-03-01

    Full Text Available We have built a 4-cell prototype plane wave transformer (PWT linac structure. We discuss here details of the design and fabrication of the PWT linac structure. We present results from superfish and gdfidl simulations as well as cold tests, which are in good agreement with each other. We also present detailed tolerance maps for the PWT structure. We discuss beam dynamics simulation studies performed using parmela.

  2. Final report on the Controlled Cold Helium Spill Test in the LHC tunnel at CERN

    CERN Document Server

    Dufay-Chanat, L; Casas-Cubillos, J; Chorowski, M; Grabowski, M; Jedrusyna, A; Lindell, G; Nonis, M; Koettig, T; Vauthier, N; van Weelderen, R; Winkler, T

    2015-01-01

    The 27 km circumference LHC underground tunnel is a space in which the helium cooled LHC magnets are installed. The vacuum enclosures of the superconducting magnets are protected by over-pressure safety relief devices that open whenever cold helium escapes either from the magnet cold enclosure or from the helium supply headers, into this vacuum enclosure. A 3-m long no stay zone around these devices is defined based on scale model studies, protecting the personnel against cold burns or asphyxia caused by such a helium release event. Recently, several simulation studies have been carried out modelling the propagation of the helium/air mixture, resulting from the opening of such a safety device, along the tunnel. The released helium flows vary in the range between 1 kg/s and 0.1 kg/s. To validate these different simulation studies, real life mock-up tests have been performed inside the LHC tunnel, releasing helium flow rates of 1 kg/s, 0.3 kg/s and 0.1 kg/s. For each test, up to 1000 liters of liquid helium wer...

  3. Backward can extrusion with conical,rotating punch as a cold forging tribology test

    DEFF Research Database (Denmark)

    Ceron, Ermanno; Bay, Niels; Tetsuo, A.

    2011-01-01

    with an analysis of the sliding velocity distribution along the punch nose. The latter is determined by FE analysis of the test. Results show friction stress for unalloyed low C-steel provided with different types of lubricants, e.g. phosphate coating plus soap, phosphate coating plus MoS2 and single bathe...... lubrication with PULS. The new test is so severe, that it is possible to break down the best lubrication systems for cold forging, such as phosphate coating plus soap and MoS2....

  4. Development of a model and test equipment for cold flow tests at 500 atm of small nuclear light bulb configurations

    Science.gov (United States)

    Jaminet, J. F.

    1972-01-01

    A model and test equipment were developed and cold-flow-tested at greater than 500 atm in preparation for future high-pressure rf plasma experiments and in-reactor tests with small nuclear light bulb configurations. With minor exceptions, the model chamber is similar in design and dimensions to a proposed in-reactor geometry for tests with fissioning uranium plasmas in the nuclear furnace. The model and the equipment were designed for use with the UARL 1.2-MW rf induction heater in tests with rf plasmas at pressures up to 500 atm. A series of cold-flow tests of the model was then conducted at pressures up to about 510 atm. At 504 atm, the flow rates of argon and cooling water were 3.35 liter/sec (STP) and 26 gal/min, respectively. It was demonstrated that the model is capable of being operated for extended periods at the 500-atm pressure level and is, therefore, ready for use in initial high-pressure rf plasma experiments.

  5. Challenges of Cold Conditioning and Static Testing the Second Ares Demonstration Motor (DM-2)

    Science.gov (United States)

    Quinn, Shyla; Davis, Larry C.

    2011-01-01

    On August 31, 2010, a five-segment demonstration motor (DM) for the Ares program was successfully tested. A series of demonstration motors (DMs) will be tested in different conditioned environments to confirm they meet their design specifications. The second demonstration motor (DM-2) was the first cold motor. The motor needed to be subjected to sub-freezing temperatures for two months so that its internal propellant mean bulk temperature (PMBT) was approximately 40 F. Several challenges had to be overcome to make this a successful test. One challenge was to condition four field joints to get the O-rings approximately 32 F. This would be done by applying conditioning shrouds to externally cool each field joint after the test bay was pulled off. The purpose of this conditioning was to validate the new O-ring design and allow joint heaters to be eliminated. Another challenge was maintaining temperature requirements for components in the nozzle vectoring system. A separate heating system was used to warm these components during cold conditioning. There were 53 test objectives that required 764 channels of data to be recorded; 460 were specific to DM-2. This instrumentation had to be installed prior to conditioning, which meant the baseline process and timeline had to be modified to meet this time critical schedule.

  6. A test procedure for energetic and performance analysis of cold appliances for the food industry

    Science.gov (United States)

    Armani, F.; Boscolo, A.

    2013-09-01

    In this article we present a novel approach for the characterization of cold appliances and in particular of refrigerators based on the standard vapour compression cycle with a reciprocating on/off compressor. The test procedure is based on a virtual instrument that perform both the stimulus and the data acquisition on the device under test. Acquired data is elaborated to fit a semi-empirical model based on the energetic balances between thermal and electrical sub systems and the heat exchanged with the environment. This approach results in a simple method to calculate useful parameters of the refrigerator, such as energetic performance, cooling effect and limit values of thermal loads. The test procedure requires only a few temperatures and the electric power consumption to be monitored, resulting in a low impact on the refrigerator. Preliminary tests showed a good estimation of parameters and prediction of energy consumption and heat extraction capacity of the refrigerator under test.

  7. NASA Ares I Launch Vehicle First Stage Roll Control System Cold Flow Development Test Program Overview

    Science.gov (United States)

    Butt, Adam; Popp, Christopher G.; Holt, Kimberly A.; Pitts, Hank M.

    2010-01-01

    The Ares I launch vehicle is the selected design, chosen to return humans to the moon, Mars, and beyond. It is configured in two inline stages: the First Stage is a Space Shuttle derived five-segment Solid Rocket Booster and the Upper Stage is powered by a Saturn V derived J-2X engine. During launch, roll control for the First Stage (FS) is handled by a dedicated Roll Control System (RoCS) located on the connecting Interstage. That system will provide the Ares I with the ability to counteract induced roll torque while any induced yaw or pitch moments are handled by vectoring of the booster nozzle. This paper provides an overview of NASA s Ares I FS RoCS cold flow development test program including detailed test objectives, types of tests run to meet those objectives, an overview of the results, and applicable lessons learned. The test article was built and tested at the NASA Marshall Space Flight Center in Huntsville, AL. The FS RoCS System Development Test Article (SDTA) is a full scale, flight representative water flow test article whose primary objective was to obtain fluid system performance data to evaluate integrated system level performance characteristics and verify analytical models. Development testing and model correlation was deemed necessary as there is little historical precedent for similar large flow, pulsing systems such as the FS RoCS. The cold flow development test program consisted of flight-similar tanks, pressure regulators, and thruster valves, as well as plumbing simulating flight geometries, combined with other facility grade components and structure. Orifices downstream of the thruster valves were used to simulate the pressure drop through the thrusters. Additional primary objectives of this test program were to: evaluate system surge pressure (waterhammer) characteristics due to thruster valve operation over a range of mission duty cycles at various feed system pressures, evaluate temperature transients and heat transfer in the

  8. A novel sputum transport solution eliminates cold chain and supports routine tuberculosis testing in Nepal

    Directory of Open Access Journals (Sweden)

    Bhagwan Maharjan

    2016-12-01

    Full Text Available This preliminary study evaluated the transport reagent OMNIgene SPUTUM (OMS in a real-world, resource-limited setting: a zonal hospital and national tuberculosis (TB reference laboratory, Nepal. The objectives were to: (1 assess the performance of OMS for transporting sputum from peripheral sites without cold chain stabilization; and (2 compare with Nepal’s standard of care (SOC for Mycobacterium tuberculosis smear and culture diagnostics. Sixty sputa were manually split into a SOC sample (airline-couriered to the laboratory, conventional processing and an OMS sample (OMS added at collection, no cold chain transport or processing. Smear microscopy and solid culture were performed. Transport was 0–8 days. Forty-one samples (68% were smear-positive using both methods. Of the OMS cultures, 37 (62% were positive, 22 (36% were negative, and one (2% was contaminated. Corresponding SOC results were 32 (53%, 21 (35%, and seven (12%. OMS “rescued” six (i.e., missed using SOC compared with one rescue using SOC. Of smear-positives, six SOC samples produced contaminated cultures whereas only one OMS sample was contaminated. OMS reduced culture contamination from 12% to 2%, and improved TB detection by 9%. The results suggest that OMS could perform well as a no cold chain, long-term transport solution for smear and culture testing. The findings provide a basis for larger feasibility studies.

  9. Testing of the Defense Waste Processing Facility Cold Chemical Dissolution Method in Sludge Batch 9 Qualification

    Energy Technology Data Exchange (ETDEWEB)

    Edwards, T. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Pareizs, J. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Coleman, C. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Young, J. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Brown, L. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2016-05-10

    For each sludge batch that is processed in the Defense Waste Processing Facility (DWPF), the Savannah River National Laboratory (SRNL) tests the applicability of the digestion methods used by the DWPF Laboratory for elemental analysis of Sludge Receipt and Adjustment Tank (SRAT) Receipt samples and SRAT Product process control samples. DWPF SRAT samples are typically dissolved using a method referred to as the DWPF Cold Chemical or Cold Chem Method (CC), (see DWPF Procedure SW4- 15.201). Testing indicates that the CC method produced mixed results. The CC method did not result in complete dissolution of either the SRAT Receipt or SRAT Product with some fine, dark solids remaining. However, elemental analyses did not reveal extreme biases for the major elements in the sludge when compared with analyses obtained following dissolution by hot aqua regia (AR) or sodium peroxide fusion (PF) methods. The CC elemental analyses agreed with the AR and PF methods well enough that it should be adequate for routine process control analyses in the DWPF after much more extensive side-by-side tests of the CC method and the PF method are performed on the first 10 SRAT cycles of the Sludge Batch 9 (SB9) campaign. The DWPF Laboratory should continue with their plans for further tests of the CC method during these 10 SRAT cycles.

  10. Experimental Investigation of Tensile Test on Connection of Cold-formed Cut-curved Steel Section

    Science.gov (United States)

    Sani, Mohd Syahrul Hisyam Mohd; Muftah, Fadhluhartini; Rahman, Nurul Farraheeda Abdul; Fakri Muda, Mohd

    2017-08-01

    Cold-formed steel (CFS) is widely used as structural and non-structural components such as roof trusses and purlin. A CFS channel section with double intermediate web stiffener and lipped is chosen based on the broader usage in roof truss construction. CFS section is cut to form cold-formed pre-cut-curved steel section and lastly strengthened by several types of method or likely known as connection to establish the cold-formed cut-curved steel (CFCCS) section. CFCCS is proposed to be used as a top chord section in the roof truss system. The CFCCS is to resist the buckling phenomena of the roof truss structure and reduced the compression effect on the top chord. The tensile test connection of CFCCS section, especially at the flange element with eight types of connection by welding, plate with self-drilling screw and combination is investigated. The flange element is the weakest part that must be solved first other than the web element because they are being cut totally, 100% of their length for curving process. The testing is done using a universal testing machine for a tensile load. From the experiment, specimen with full welding has shown as a good result with an ultimate load of 13.37 kN and reported having 35.41% when compared with normal specimen without any of connection methods. Furthermore, the experimental result is distinguished by using Eurocode 3. The failure of a full welding specimen is due to breaking at the welding location. Additionally, all specimens with either full weld or spot weld or combination failed due to breaking on weld connection, but specimen with flange plate and self-drilling screw failed due to tilting and bearing. Finally, the full welding specimen is chosen as a good connection to perform the strengthening method of CFCCS section.

  11. Design and Test of a Liquid Oxygen / Liquid Methane Thruster with Cold Helium Pressurization Heat Exchanger

    Science.gov (United States)

    Melcher, John C.; Morehead, Robert L.; Atwell, Matthew J.; Hurlbert, Eric A.

    2015-01-01

    A liquid oxygen / liquid methane 2,000 lbf thruster was designed and tested in conjuction with a nozzle heat exchanger for cold helium pressurization. Cold helium pressurization systems offer significant spacecraft vehicle dry mass savings since the pressurant tank size can be reduced as the pressurant density is increased. A heat exchanger can be incorporated into the main engine design to provide expansion of the pressurant supply to the propellant tanks. In order to study the systems integration of a cold-helium pressurization system, a 2,000 lbf thruster with a nozzle heat exchanger was designed for integration into the Project Morpheus vehicle at NASA Johnson Space Center. The testing goals were to demonstrate helium loading and initial conditioning to low temperatures, high-pressure/low temperature storage, expansion through the main engine heat exchanger, and propellant tank injection/pressurization. The helium pressurant tank was an existing 19 inch diameter composite-overwrap tank, and the targert conditions were 4500 psi and -250 F, providing a 2:1 density advantage compared to room tempatrue storage. The thruster design uses like-on-like doublets in the injector pattern largely based on Project Morpheus main engine hertiage data, and the combustion chamber was designed for an ablative chamber. The heat exchanger was installed at the ablative nozzle exit plane. Stand-alone engine testing was conducted at NASA Stennis Space Center, including copper heat-sink chambers and highly-instrumented spoolpieces in order to study engine performance, stability, and wall heat flux. A one-dimensional thermal model of the integrated system was completed. System integration into the Project Morpheus vehicle is complete, and systems demonstrations will follow.

  12. W-026 integrated engineering cold run operational test report for balance of plant (BOP)

    Energy Technology Data Exchange (ETDEWEB)

    Kersten, J.K.

    1998-02-24

    This Cold Run test is designed to demonstrate the functionality of systems necessary to move waste drums throughout the plant using approved procedures, and the compatibility of these systems to function as an integrated process. This test excludes all internal functions of the gloveboxes. In the interest of efficiency and support of the facility schedule, the initial revision of the test (rev 0) was limited to the following: Receipt and storage of eight overpacked drums, four LLW and four TRU; Receipt, routing, and staging of eleven empty drums to the process area where they will be used later in this test; Receipt, processing, and shipping of two verification drums (Route 9); Receipt, processing, and shipping of two verification drums (Route 1). The above listed operations were tested using the rev 0 test document, through Section 5.4.25. The document was later revised to include movement of all staged drums to and from the LLW and TRU process and RWM gloveboxes. This testing was performed using Sections 5.5 though 5.11 of the rev 1 test document. The primary focus of this test is to prove the functionality of automatic operations for all mechanical and control processes listed. When necessary, the test demonstrates manual mode operations as well. Though the gloveboxes are listed, only waste and empty drum movement to, from, and between the gloveboxes was tested.

  13. Aerobic exercise and cold pressor test induce hypoalgesia in active and inactive men and women

    DEFF Research Database (Denmark)

    Vægter, Henrik Bjarke; Handberg, Gitte; Jørgensen, Maria N.

    2015-01-01

    . It was hypothesized that active subjects had more efficient pain inhibition compared with inactive subjects. DESIGN: A randomized, crossover study with 2 days of data collection. METHODS: Fifty-six (28 females) subjects participated in this study. Subjects were subgrouped into active (n = 30) and inactive (n = 26......). Conditioned pain modulation (CPM) was assessed by cold pressor testing. Exercise-induced hypoalgesia (EIH) was assessed after 15 minutes bicycling at a heart rate corresponding to 75% VO2max. A control session of 15 minutes quiet rest was also included. Pressure pain thresholds (PPTs) were recorded...

  14. Challenges of Cold Conditioning and Static Testing the Ares Demonstration Motor (DM-2)

    Science.gov (United States)

    Quinn, Shyla; Davis, Larry C.

    2011-01-01

    The Ares first stage rocket is a "human-rated" motor capable of producing and sustaining 3.5 million pounds of thrust throughout it s two-minute burn period. A series of demonstration motors (DM) will be tested in different conditioned environments to confirm they meet all design specifications. The second demonstration motor (DM-2) was designated to be a "cold motor", this means the internal propellant mean bulk temperature (PMBT) was 40 +5\\-3 F. The motor was subjected to subfreezing temperatures for two months.

  15. Cold pressor test as a predictor of the severity of hypertension.

    Science.gov (United States)

    Loyke, H F

    1995-03-01

    This report examines the cold pressor test (CPT) as it relates to the severity of hypertension. A total of 123 hypertensive patients were studied by physical examination, retinal funduscopy, chest roentgenogram, electrocardiogram, blood urea nitrogen measurement, and urinalysis. Causal and valid basal resting blood pressure determinations were made, followed by immersion of one hand in ice water for 2 minutes. All 21 patients with arteriosclerotic, 78 with essential, and 24 with renal hypertension had hyperreactive responses to the CPT (> 20/20 mm Hg) as compared with the normotensive subjects. The CPT-induced increase in diastolic pressure was significantly higher in hypertensives with left ventricular hypertrophy (LVH). CPT responses were also greater in hypertensives with higher degrees of retinopathy. These findings indicate that the diastolic rise on cold pressor testing can be used as a measure of severity of hypertension, especially in the presence of LVH and severe retinopathy. The CPT is inexpensive and noninvasive and can aid the clinician in managing the hypertensive patient. The CPT may also be useful as a predictor of complications of hypertension in selected individuals.

  16. Final Report - Spent Nuclear Fuel Retrieval System Manipulator System Cold Validation Testing

    Energy Technology Data Exchange (ETDEWEB)

    D.R. Jackson; G.R. Kiebel

    1999-08-24

    Manipulator system cold validation testing (CVT) was performed in support of the Fuel Retrieval System (FRS) Sub-Project, a subtask of the Spent Nuclear Fuel Project at the Hanford Site in Richland, Washington. The FRS will be used to retrieve and repackage K-Basin Spent Nuclear Fuel (SNF) currently stored in old K-Plant storage basins. The FRS is required to retrieve full fuel canisters from the basin; clean the fuel elements inside the canister to remove excessive uranium corrosion products (or sludge); remove the contents from the canisters; and sort the resulting debris, scrap, and fuel for repackaging. The fuel elements and scrap will be collected in fuel storage and scrap baskets in preparation for loading into a multi canister overpack (MCO), while the debris is loaded into a debris bin and disposed of as solid waste. The FRS is composed of three major subsystems. The Manipulator Subsystem provides remote handling of fuel, scrap, and debris; the In-Pool Equipment subsystem performs cleaning of fuel and provides a work surface for handling materials; and the Remote Viewing Subsystem provides for remote viewing of the work area by operators. There are two complete and identical FRS systems, one to be installed in the K-West basin and one to be installed in the K-East basin. Another partial system will be installed in a cold test facility to provide for operator training.

  17. Determinants of myocardial blood flow response to cold pressor testing and pharmacologic vasodilation in healthy humans

    Energy Technology Data Exchange (ETDEWEB)

    Prior, John O.; Schindler, Thomas H.; Facta, Alvaro D.; Hernandez-Pampaloni, Miguel; Campisi, Roxana; Dahlbom, Magnus; Schelbert, Heinrich R. [David Geffen School of Medicine at UCLA, Department of Molecular and Medical Pharmacology, B2-085J CHS, 10833 Le Conte Ave, Box 956948, Los Angeles, CA (United States)

    2007-01-15

    Response of myocardial blood flow (MBF) to sympathetic stimulation with cold is modulated by endothelium-related factors and is typically altered in the presence of coronary risk factors. Determinants of flow response to cold pressor testing (CPT) in normal volunteers at low risk for CAD remain less well defined, especially relative to baseline conditions such as hemodynamics and MBF, plasma substrate and lipid levels, and total pharmacologically stimulated vasodilator capacity. In 50 normal volunteers (42{+-}13 years; 31 women) without coronary risk factors, insulin resistance, or family history of diabetes/premature CAD, MBF was measured with {sup 13}N-ammonia and PET at baseline, during CPT, and during pharmacologic hyperemia. Sympathetic stimulation with CPT raised heart rate and blood pressure and thus MBF ({delta}MBF=0.23{+-}0.09 ml/min/g). MBF response, defined in absolute flow units as the difference between CPT and baseline, was independent of age, gender, heart rate, and blood pressure and rate-pressure product (RPP) at baseline as well as plasma substrate and lipid levels with the exception of an association with HDL cholesterol ({rho}=0.40, p=0.005) but depended on the change in RPP from rest ({rho}=0.33, p=0.019). Finally, changes in coronary vascular resistance in response to CPT were associated with changes in pharmacologic vasodilation ({rho}=0.56, p<0.0001). MBF response to sympathetic stimulation with cold (NO-mediated endothelium-dependent vasomotion), reflecting the functional state of the coronary endothelium, was independent of gender, age, and resting heart conditions. It was modulated by HDL cholesterol levels, even in healthy volunteers, and also related to pharmacologically stimulated vasodilator capacity at the coronary vascular resistance level. (orig.)

  18. Alternative procedure for the cold test for soybean seeds Procedimento alternativo para o teste de frio em semente de soja

    Directory of Open Access Journals (Sweden)

    Bruno Guilherme Torres Licursi Vieira

    2010-10-01

    Full Text Available The growing demand for high quality soybean [Glycine max (L. Merrill] seeds requires a precise seed quality control system from the seed industry. One way to accomplish this is by improving vigor testing. Cold test has been traditionally employed for corn seeds. However, it has also been used for other seed crops such as cotton (Gossypium spp., soybean (Glycine Max, dry bean (Phaseolus vulgaris and pea (Pisum sativum. This study was carried out with the objective of adjusting an alternative procedure for the cold test to determine soybean seed vigor. Six commercial soybean seed lots of the cultivar BRS 133 were used. The physiological potential of the seed lots was evaluated by germination on paper towel and sand box, seedling field emergence, tetrazolium, accelerated aging and electrical conductivity tests. Seed moisture content was also determined. The temperature used for the cold test procedures was 10ºC during five days. Four cold test procedures were evaluated: i plastic boxes with soil; ii rolled paper towel with soil; iii rolled paper towel without soil, and iv an alternative procedure, using rolled paper towel without soil under cold water. A completely randomized experimental design with eight replications was used and the means were compared by the Tukey test (p = 0.05. To verify the dependence between the alternative test and others single linear correlation was used. All cold test procedures had similar coefficients of variation (CV, highlighting that rolled paper towel with soil and the alternative procedure had the best performance, with an average of 94% and 93% normal seedlings and CV of 3.2% and 3.6%, respectively. The alternative procedure has satisfactory results for estimating soybean seed vigor, yielding consistent results compared to the traditional procedure.A crescente demanda por semente de soja [Glycine max (L. Merrill] de alta qualidade tem requerido da indústria de sementes um controle de qualidade mais preciso

  19. Three-Dimensional Simulation of Traveling-Wave Tube Cold-Test Characteristics Using MAFIA

    Science.gov (United States)

    Kory, Carol L.; Wilson, Jeffrey D.

    1995-01-01

    The three-dimensional simulation code MAFIA was used to compute the cold-test parameters - frequency-phase dispersion, beam on-axis interaction impedance, and attenuation - for two types of traveling-wave tube (TWT) slow-wave circuits. The potential for this electromagnetic computer modeling code to reduce the time and cost of TWT development is demonstrated by the high degree of accuracy achieved in calculating these parameters. Generalized input files were developed for ferruled coupled-cavity and TunneLadder slow-wave circuits. These files make it easy to model circuits of arbitrary dimensions. The utility of these files was tested by applying each to a specific TWT slow-wave circuit and comparing the results with experimental data. Excellent agreement was obtained.

  20. Compression test of cold-formedsteel perforated profile with steel sheathing

    Directory of Open Access Journals (Sweden)

    Shamanin Aleksandr Yur’evich

    2015-05-01

    Full Text Available The subject of this paper is the stability and strength of cold-formed and perforated steel sigma-section columns with steel sheathing of different thickness. Ceilings with and without steel sheathing of different thickness are tested to failure in compression on a laboratory machine, which was based on a manual hydraulic jack. Series of 4 experiments with full-scale walls (2.5 m height were carried out. Also, for examination of the role of boundary conditions, the sheet in a ceiling is either left free or connected to base with screws.In civil engineering there are many experiments and methodologies for calculating the strength and buckling of ceiling with the sheathing of various materials, such as oriented strand board and gypsum board. However, for producing superstructures of ships the materials with high plastic properties and strength characteristics are required. For example steel possesses such properties. It was the main reason for conducting a series of experiments and studying the behavior of cold-formed steel columns with steel sheathing. During the experiments the deformation of the cross-section of three equally spaced cross sections was determined, as well as the axial deformation of the central column in the ceiling with steel sheathing.The test results showed the influence of the thickness of sheathing and boundary condition of a sheet on the strength and buckling of ceiling. According to the results of the tests it is necessary to evaluate the impact of the sheathing made of different materials and if necessary to carry out further tests.

  1. Preoperative hypoalgesia after cold pressor test and aerobic exercise is associated with pain relief six months after total knee replacement

    DEFF Research Database (Denmark)

    Vaegter, Henrik Bjarke; Handberg, Gitte; Emmeluth, Claus

    2017-01-01

    investigated the association between exercise-induced hypoalgesia (EIH) and CPM on post-TKR pain relief. METHODS: Before and six months post-TKR, 14 patients with chronic knee osteoarthritis performed the cold pressor test on the non-affected leg and two exercise conditions (bicycling and isometric knee...... extension), randomized and counterbalanced. Before and during the cold pressor test and after exercises test-stimuli were applied to extract the pain sensitivity difference: Computer-controlled cuff inflation on the affected lower leg until the subjects detected the cuff pain threshold (c...... at the affected leg improved post-TKR compared with pre-TKR (P

  2. Alexandria fluidized-bed process development unit: cold-mode testing

    Energy Technology Data Exchange (ETDEWEB)

    None

    1981-02-01

    The objectives of the current test program include: validation of predictions from the Massachusetts Institute of Technology (MIT) Coal Atmospheric Fluidized Bed Combustor System Model; experimental studies supporting AFBC process developments; and the collection of transient data for process control design. This topical report summarizes results from cold mode testing, i.e., experiments performed without combustion for MIT Model verification. During these tests, sulfated limestone (generated from normal AFBC operations) was fluidized with air at temperatures ranging from 80 to 500/sup 0/F in the 3' x 3' (nominal) size PDU at Alexandria, VA. The MIT Model predictions tested include: slumped bed height, minimum fluidization velocity, and expanded bed height. In all cases, there were large discrepancies between the Model predictions and corresponding experimental results. Other results obtained included solids size distribution and particle size profiles in the bed. Size distribution was adequately modeled by the Rosin-Rammler equation. No transient process data was collected due to hardware problems with the Data Acquisition System. Tests were also performed to determine the effect of maldistribution of air, caused by leaks in the air distributor, on experimental results. The data indicated that effects of these leaks seemed to be undetectable.

  3. Mild dehydration modifies the cerebrovascular response to the cold pressor test.

    Science.gov (United States)

    Perry, Blake G; Bear, Tracey L K; Lucas, Samuel J E; Mündel, Toby

    2016-01-01

    The cold pressor test (CPT) is widely used in clinical practice and physiological research. It is characterized by a robust autonomic response, with associated increases in heart rate (HR), mean arterial pressure (MAP) and mean middle cerebral artery blood flow velocity (MCAv(mean)). Hydration status is not commonly reported when conducting this test, yet blood viscosity alone can modulate MCAv(mean), potentially modifying the MCAv(mean) response to the CPT. We investigated the effect of mild dehydration on the physiological response to the CPT in 10 healthy men (mean ± SD: age 28 ± 5 years; body mass 83 ± 5 kg). All participants completed two CPTs, cold water (0°C) immersion of both feet for 90 s, with the order of the euhydration and dehydration trials counterbalanced. Beat-to-beat MCAv, MAP, HR and breath-by-breath partial pressure of end-tidal CO2 (P(ET,CO2)) were measured continuously. Participants' pain perception was measured 1 min into the CPT using a visual analog scale (no pain = 0; maximal pain = 10). Dehydration significantly elevated plasma osmolality and urine specific gravity and reduced body mass (all P 0.05). After 90 s of immersion, the change in MCAv(mean) from baseline was less in the dehydration compared with the euhydration trial (change 0 ± 5 versus 7 ± 7 cm s(-1), P = 0.01), as was P(ET,CO2) (change -3 ± 2 versus 0 ± 3 mmHg, P = 0.02). Dehydration was associated with greater relative pain sensation during the CPT (7.0 ± 1.3 vs 5.8 ± 1.8, P = 0.02). Our results demonstrate that mild dehydration can modify the cerebrovascular response to the CPT, with dehydration increasing perceived pain, lowering P ET ,CO2 and, ultimately, blunting the MCAv(mean) response. © 2015 The Authors. Experimental Physiology © 2015 The Physiological Society.

  4. Characterization of Ceramic Material Produced From a Cold Crucible Induction Melter Test

    Energy Technology Data Exchange (ETDEWEB)

    Amoroso, J. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Marra, J. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2015-04-30

    This report summarizes the results from characterization of samples from a melt processed surrogate ceramic waste form. Completed in October of 2014, the first scaled proof of principle cold crucible induction melter (CCIM) test was conducted to process a Fe-hollandite-rich titanate ceramic for treatment of high level nuclear waste. X-ray diffraction, electron microscopy, inductively coupled plasma-atomic emission spectroscopy (and inductively coupled plasma-mass spectroscopy for Cs), and product consistency tests were used to characterize the CCIM material produced. Core samples at various radial locations from the center of the CCIM were taken. These samples were also sectioned and analyzed vertically. Together, the various samples were intended to provide an indication of the homogeneity throughout the CCIM with respect to phase assemblage, chemical composition, and chemical durability. Characterization analyses confirmed that a crystalline ceramic with desirable phase assemblage was produced from a melt using a CCIM. Hollandite and zirconolite were identified in addition to possible highly-substituted pyrochlore and perovskite. Minor phases rich in Fe, Al, or Cs were also identified. Remarkably only minor differences were observed vertically or radially in the CCIM material with respect to chemical composition, phase assemblage, and durability. This recent CCIM test and the resulting characterization in conjunction with demonstrated compositional improvements support continuation of CCIM testing with an improved feed composition and improved melter system.

  5. Quantitative and Qualitative Responses to Topical Cold in Healthy Caucasians Show Variance between Individuals but High Test-Retest Reliability.

    Directory of Open Access Journals (Sweden)

    Penny Moss

    Full Text Available Increased sensitivity to cold may be a predictor of persistent pain, but cold pain threshold is often viewed as unreliable. This study aimed to determine the within-subject reliability and between-subject variance of cold response, measured comprehensively as cold pain threshold plus pain intensity and sensation quality at threshold. A test-retest design was used over three sessions, one day apart. Response to cold was assessed at four sites (thenar eminence, volar forearm, tibialis anterior, plantar foot. Cold pain threshold was measured using a Medoc thermode and standard method of limits. Intensity of pain at threshold was rated using a 10cm visual analogue scale. Quality of sensation at threshold was quantified with indices calculated from subjects' selection of descriptors from a standard McGill Pain Questionnaire. Within-subject reliability for each measure was calculated with intra-class correlation coefficients and between-subject variance was evaluated as group coefficient of variation percentage (CV%. Gender and site comparisons were also made. Forty-five healthy adults participated: 20 male, 25 female; mean age 29 (range 18-56 years. All measures at all four test sites showed high within-subject reliability: cold pain thresholds r = 0.92-0.95; pain rating r = 0.93-0.97; McGill pain quality indices r = 0.87-0.85. In contrast, all measures showed wide between-subject variance (CV% between 51.4% and 92.5%. Upper limb sites were consistently more sensitive than lower limb sites, but equally reliable. Females showed elevated cold pain thresholds, although similar pain intensity and quality to males. Females were also more reliable and showed lower variance for all measures. Thus, although there was clear population variation, response to cold for healthy individuals was found to be highly reliable, whether measured as pain threshold, pain intensity or sensation quality. A comprehensive approach to cold response testing therefore may add

  6. Assessment of the Effectiveness of Modular Clothing Protecting Against the Cold Based on Physiological Tests.

    Science.gov (United States)

    Marszałek, Anna; Bartkowiak, Grażyna; Dąbrowska, Anna

    2017-09-19

    At many work stations under cold environment, protective clothing, which is provided for the workers is characterized by an inadequate thermal insulation, which results in an adverse impact of cold environment on a worker's body. The purpose of this paper is to present a developed new ergonomic modular cold protective clothing, which allows for easy adaptation of the thermal insulation of clothing to worker's individual needs. This clothing was compared in a laboratory study with the clothing having been used so far by workers of cold environment using physiological and physical measurements, subjective ratings of thermal state as well a questionnaire of subjective assessment of used clothing. These measurements and ratings confirmed that the modular cold protective clothing is more effective in the process of ensuring thermal comfort to the wearer during work in a cold environment than the clothing having been used so far.

  7. Accurate anisotropic material modelling using only tensile tests for hot and cold forming

    Science.gov (United States)

    Abspoel, M.; Scholting, M. E.; Lansbergen, M.; Neelis, B. M.

    2017-09-01

    Accurate material data for simulations require a lot of effort. Advanced yield loci require many different kinds of tests and a Forming Limit Curve (FLC) needs a large amount of samples. Many people use simple material models to reduce the effort of testing, however some models are either not accurate enough (i.e. Hill’48), or do not describe new types of materials (i.e. Keeler). Advanced yield loci describe the anisotropic materials behaviour accurately, but are not widely adopted because of the specialized tests, and data post-processing is a hurdle for many. To overcome these issues, correlations between the advanced yield locus points (biaxial, plane strain and shear) and mechanical properties have been investigated. This resulted in accurate prediction of the advanced stress points using only Rm, Ag and r-values in three directions from which a Vegter yield locus can be constructed with low effort. FLC’s can be predicted with the equations of Abspoel & Scholting depending on total elongation A80, r-value and thickness. Both predictive methods are initially developed for steel, aluminium and stainless steel (BCC and FCC materials). The validity of the predicted Vegter yield locus is investigated with simulation and measurements on both hot and cold formed parts and compared with Hill’48. An adapted specimen geometry, to ensure a homogeneous temperature distribution in the Gleeble hot tensile test, was used to measure the mechanical properties needed to predict a hot Vegter yield locus. Since for hot material, testing of stress states other than uniaxial is really challenging, the prediction for the yield locus adds a lot of value. For the hot FLC an A80 sample with a homogeneous temperature distribution is needed which is due to size limitations not possible in the Gleeble tensile tester. Heating the sample in an industrial type furnace and tensile testing it in a dedicated device is a good alternative to determine the necessary parameters for the FLC

  8. Comparação entre os processos de Cold Test e Hot Test em uma empresa fabricante de motores diesel

    Directory of Open Access Journals (Sweden)

    Pablo Fogaça

    2017-10-01

    Full Text Available Resumo O teste a frio (Cold Test é um processo inovador no Brasil com relação aos testes em motores diesel. Esse processo foi implementado em uma empresa fabricante de motores diesel, com o intuito de ser o principal teste de validação antes de os motores serem enviados ao cliente. Partindo-se dessa hipótese, surgiu o principal motivo desta investigação: é possível a substituição plena do teste a quente (Hot Test pelo teste a frio (Cold Test? Essa foi uma pergunta impactante, visto que o Hot Test é um processo confiável e consagrado há mais de 18 anos. O método utilizado nesta pesquisa foi o estudo de caso. A investigação detalhada identificou vários critérios de comparação dos dois processos, tais como: fluxogramas, eficácia, eficiência, complexidade, níveis de aprovação, planilhas de bordo e documentos FMEA da empresa. Os resultados mostraram que o processo Cold Test é mais vantajoso e sustentável, entretanto os dois processos são complementares. O estudo comprovou que não foi possível a plena substituição do Hot Test pelo Cold Test, principalmente pelo fato da não detecção de vazamentos no processo Cold Test.

  9. THE RESULTS OF TESTING TO EVALUATE CRYSTAL FORMATION AND SETTLING IN THE COLD CRUCIBLE INDUCTION MELTER

    Energy Technology Data Exchange (ETDEWEB)

    Marra, J.

    2009-06-30

    The Cold Crucible Induction Melter (CCIM) technology offers the potential to increase waste loading for High Level Waste (HLW) glasses leading to significant improvements in waste throughput rates compared to the reference Joule Heated Melter (JHM). Prior to implementation of a CCIM in a production facility it is necessary to better understand processing constraints associated with the CCIM. The glass liquidus temperature requirement for processing in the CCIM is an open issue. Testing was conducted to evaluate crystal formation and crystal settling during processing in the CCIM to gain insight into the effects on processing. A high aluminum/high iron content glass composition with known crystal formation tendencies was selected for testing. A continuous melter test was conducted for approximately 51 hours. To evaluate crystal formation, glass samples were obtained from pours and from glass receipt canisters where the glass melt had varying residence time in the melter. Additionally, upon conclusion of the testing, glass samples from the bottom of the melter were obtained to assess the degree of crystal settling. Glass samples were characterized in an attempt to determine quantitative fractions of crystals in the glass matrix. Crystal identity and relative composition were determined using a combination of x-ray diffraction (XRD) and scanning electron microscopy coupled with energy dispersive spectroscopy (SEM/EDS). Select samples were also analyzed by digesting the glass and determining the composition using inductively coupled atomic emission spectroscopy (ICP-AES). There was evidence of crystal formation (primarily spinels) in the melt and during cooling of the collected glass. There was evidence of crystal settling in the melt over the duration of the melter campaign.

  10. Dipyridamole, cold pressor test, and demonstration of endothelial dysfunction: a PET study of myocardial perfusion in diabetes

    DEFF Research Database (Denmark)

    Kjaer, Andreas; Meyer, Christian; Nielsen, Flemming S

    2003-01-01

    Much evidence suggests endothelial dysfunction to be present in non-insulin-dependent diabetes mellitus (NIDDM) and to be important for the development of myocardial ischemia. Endothelial function in the coronary vessels may be studied in various ways. We compared the effect of cold pressor testing...

  11. Ghrelin levels after a cold pressor stress test in obese women with binge eating disorder.

    Science.gov (United States)

    Gluck, Marci E; Yahav, Eric; Hashim, Sami A; Geliebter, Allan

    2014-01-01

    Ghrelin, a peptide hormone secreted mainly by the stomach, increases appetite and food intake. Surprisingly, ghrelin levels are lower in obese individuals with binge eating disorder (BED) than in obese non-BED individuals. Acute psychological stress has been shown to raise ghrelin levels in animals and humans. Our aim was to assess ghrelin levels after a cold pressor test (CPT) in women with BED. We also examined the relationship between the cortisol stress response and changes in ghrelin levels. Twenty-one obese (mean [standard deviation] body mass index = 34.9 [5.8] kg/m(2)) women (10 non-BED, 11 BED) underwent the CPT, hand submerged in ice water for 2 minutes. Blood samples were drawn for 70 minutes and assayed for ghrelin and cortisol. There were no differences between the groups in ghrelin levels at baseline (-10 minutes). Ghrelin rose significantly after the CPT (F = 2.4, p = .024) peaking at 19 minutes before declining (F = 17.9, p stress, hunger, or desire to eat after CPT. In addition, there were no observed relationships between the area under the curves for ghrelin or cortisol after stress. Although there were no differences between BED groups, there was a significant rise in ghrelin in obese humans after a stressor, consistent with other recent reports suggesting a stress-related role for ghrelin.

  12. Sympathetic activation by the cold pressor test does not increase the muscle force generation capacity.

    Science.gov (United States)

    Roatta, Silvestro; Farina, Dario

    2011-06-01

    A positive inotropic action by the sympathetic nervous system on skeletal muscles has been observed and investigated in animal and in vitro studies. This action provided a theoretical basis for the putative ergogenic action of catecholamines and adrenergic agonists, although there is no clear evidence of this effect in humans. The aim of this study was to investigate the occurrence of inotropic effects associated to physiological sympathetic activation in healthy subjects. The muscle force capacity was investigated in the tibialis anterior (n = 9 subjects) and in the soleus (n = 9) muscles electrically stimulated with single pulses and double pulses with variable interspike interval (4-1,000 ms) and short pulse trains (frequency: 5-14 Hz) before, during, and after sympathetic activation by the cold pressor test (CPT). CPT significantly decreased by 10.4 ± 7.2 and 10.6 ± 4.4% the force produced by single and double pulse stimulation, respectively, and produced smaller decreases in the force obtained by train stimulation in the tibialis anterior, while no significant changes were observed in either type of contraction in the soleus muscle. CPT failed to induce any increase in the force capacity of the investigated muscles. The prevalent decrease in force evidenced in this study supports the concept that the weakening sympathetic action on type I fiber, already shown to occur in humans, prevails over the putative potentiating action.

  13. Anesthesia machine checkout and room setup: a randomized, single-blind, comparison of two teaching modalities.

    Science.gov (United States)

    Spofford, Christina M; Bayman, Emine O; Szeluga, Debra J; From, Robert P

    2012-01-01

    Novel methods for teaching are needed to enhance the efficiency of academic anesthesia departments as well as provide approaches to learning that are aligned with current trends and advances in technology. A video was produced that taught the key elements of anesthesia machine checkout and room set up. Novice learners were randomly assigned to receive either the new video format or traditional lecture-based format for this topic during their regularly scheduled lecture series. Primary outcome was the difference in written examination score before and after teaching between the two groups. Secondary outcome was the satisfaction score of the trainees in the two groups. Forty-two students assigned to the video group and 36 students assigned to the lecture group completed the study. Students in each group similar interest in anesthesia, pre-test scores, post-test scores, and final exam scores. The median posttest to pretest difference was greater in the video groups (3.5 (3.0-5.0) vs 2.5 (2.0-3.0), for video and lecture groups respectively, p 0.002). Despite improved test scores, students reported higher satisfaction the traditional, lecture-based format (22.0 (18.0-24.0) vs 24.0 (20.0-28.0), for video and lecture groups respectively, p teaching group, however students rated traditional, live lectures higher than newer video-based teaching.

  14. Cold Helium Pressurization for Liquid Oxygen/Liquid Methane Propulsion Systems: Fully-Integrated Hot-Fire Test Results

    Science.gov (United States)

    Morehead, R. L.; Atwell, M. J.; Melcher, J. C.; Hurlbert, E. A.

    2016-01-01

    Hot-fire test demonstrations were successfully conducted using a cold helium pressurization system fully integrated into a liquid oxygen (LOX) / liquid methane (LCH4) propulsion system (Figure 1). Cold helium pressurant storage at near liquid nitrogen (LN2) temperatures (-275 F and colder) and used as a heated tank pressurant provides a substantial density advantage compared to ambient temperature storage. The increased storage density reduces helium pressurant tank size and mass, creating payload increases of 35% for small lunar-lander sized applications. This degree of mass reduction also enables pressure-fed propulsion systems for human-rated Mars ascent vehicle designs. Hot-fire test results from the highly-instrumented test bed will be used to demonstrate system performance and validate integrated models of the helium and propulsion systems. A pressurization performance metric will also be developed as a means to compare different active pressurization schemes.

  15. Acetylcholine versus cold pressor testing for evaluation of coronary endothelial function.

    Directory of Open Access Journals (Sweden)

    Ahmed AlBadri

    Full Text Available Assessment of coronary endothelial function with intracoronary acetylcholine (IC-Ach provides diagnostic and prognostic data in patients with suspected coronary microvascular dysfunction (CMD, but is often not feasible due in part to the time and expertise needed for pharmacologic mixing. Cold pressor testing (CPT is a simple and safe stimulus useful for either invasive or non-invasive endothelial function testing and myocardial perfusion imaging but has not been specifically evaluated among symptomatic women with signs of ischemic heart disease (IHD who have no obstructive coronary artery disease (CAD.163 women with signs and symptoms of IHD and no obstructive CAD from the NHLBI- Women's Ischemia Syndrome Evaluation-Coronary Vascular Dysfunction (WISE-CVD study underwent coronary reactivity testing with a Doppler flow wire (FloWire® Volcano, San Diego, CA in the proximal left anterior descending artery. Coronary artery diameter and coronary blood flow (CBF assessed by core lab using QCA before and after IC-Ach (18.2 μg/ml infused over 3 minutes and during CPT.Mean age was 55 ± 12 years. Rate pressure product (RPP in response to IC-Ach did not change (baseline to peak, P = 0.26, but increased during CPT (363±1457; P = 0.0028. CBF in response to CPT was poorly correlated to IC-Ach CBF. Change in coronary artery diameter after IC-Ach correlated with change after CPT (r = 0.59, P<0.001. The correlation coefficient was stronger in subjects with coronary dilation to IC-Ach (r = 0.628, P<0.001 versus those without dilation (r = 0.353, P = 0.002, suggesting that other factors may be important to this relationship when endothelium is abnormal.In women with no obstructive CAD and suspected CMD, coronary diameter changes with IC-Ach and CPT are moderately-well correlated suggesting that CPT testing may be of some use, particularly among patients with normal endothelial function, however, not an alternative to IC-Ach for diagnosis of coronary

  16. Effect of generalised sympathetic activation by cold pressor test on cerebral haemodynamics in healthy humans.

    Science.gov (United States)

    Roatta, S; Micieli, G; Bosone, D; Losano, G; Bini, R; Cavallini, A; Passatore, M

    1998-07-15

    There is no general agreement regarding several aspects of the role of the sympathetic system on cerebral haemodynamics such as extent of effectiveness, operational range and site of action. This study was planned to identify the effect of a generalised sympathetic activation on the cerebral haemodynamics in healthy humans before it is masked by secondary corrections, metabolic or myogenic in nature. A total of 35 healthy volunteers aged 20-35 underwent a 5 min lasting cold pressor test (CPT) performed on their left hand. The cerebral blood flow (CBF) velocity in the middle cerebral arteries and arterial blood pressure were recorded with transcranial Doppler sonography and with a non-invasive finger-cuff method, respectively. The ratio of arterial blood pressure to mean blood velocity (ABP/Vm) and Pulsatility Index (PI) were calculated throughout each trial. CPT induced an increase in mean ABP (range 2-54 mmHg depending on the subject) and only a slight, though significant, increase in blood velocity in the middle cerebral artery (+2.4 and +4.4% on ipsi- and contralateral side, respectively). During CPT, the ratio ABP/Vm increased and PI decreased in all subjects on both sides. These changes began simultaneously with the increase in blood pressure. The increase in ABP/Vm ratio is attributed to an increase in the cerebrovascular resistance, while the concomitant reduction in PI is interpreted as due to the reduction in the compliance of the middle cerebral artery. The results suggest that generalised increases in the sympathetic discharge, causing increases in ABP, can prevent concomitant increases in CBF by acting on both small resistance and large compliant vessels. This effect is also present when a slight increase in blood pressure occurs, which suggests a moderate increase in the sympathetic discharge, i.e. when ABP remains far below the upper limit of CBF autoregulation.

  17. [Physicians with access to point-of-care tests significantly reduce the antibiotic prescription for common cold].

    Science.gov (United States)

    Llor, Carles; Hernández, Silvia; Cots, Josep María; Bjerrum, Lars; González, Beatriz; García, Guillermo; Alcántara, Juan de Dios; Guerra, Gloria; Cid, Marina; Gómez, Manuel; Ortega, Jesús; Pérez, Carolina; Arranz, Javier; Monedero, María José; Paredes, José; Pineda, Vicenta

    2013-03-01

    This study was aimed at evaluating the effect of two levels of intervention on the antibiotic prescribing in patients with common cold. Before and after audit-based study carried out in primary healthcare centres in Spain. General practitioners registered all the episodes of common cold during 15 working days in January and February in 2008 (preintervention). Two types of intervention were considered: full intervention, consisting in individual feedback based on results from the first registry, courses in rational antibiotic prescribing, guidelines, patient information leaflets, workshops on rapid tests -rapid antigen detection and C-reactive protein tests- and provision of these tests in the surgeries; and partial intervention, consisting of all the above intervention except for the workshop and they did not have access to rapid tests. The same registry was repeated in 2009 (postintervention). In addition, new physicians filled out only the registry in 2009 (control group). 210 physicians underwent the full intervention, 71 the partial intervention and 59 were assigned to the control group. The 340 doctors prescribed antibiotics in 274 episodes of a total of 12,373 cases registered (2.2%).The greatest percentage of antibiotic prescription was found in the control group (4.6%). The partial intervention increased the antibiotic prescription percentage from 1.1% to 2.7% while only doctors who underwent the complete intervention lead to a significant reduction of antibiotics prescribed, from 2.9% before to 0.7% after the intervention (pcommon cold.

  18. 2016 Annual Reuse Report for the Idaho National Laboratory Site’s Advanced Test Reactor Complex Cold Waste Ponds

    Energy Technology Data Exchange (ETDEWEB)

    Lewis, Michael George [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2017-02-01

    This report describes conditions and information, as required by the state of Idaho, Department of Environmental Quality Reuse Permit I-161-02, for the Advanced Test Reactor Complex Cold Waste Ponds located at Idaho National Laboratory from November 1, 2015–October 31, 2016. The effective date of Reuse Permit I-161-02 is November 20, 2014 with an expiration date of November 19, 2019. This report contains the following information: • Facility and system description • Permit required effluent monitoring data and loading rates • Permit required groundwater monitoring data • Status of compliance activities • Issues • Discussion of the facility’s environmental impacts. During the 2016 permit year, 180.99 million gallons of wastewater were discharged to the Cold Waste Ponds. This is well below the maximum annual permit limit of 375 million gallons. As shown by the groundwater sampling data, sulfate and total dissolved solids concentrations are highest in well USGS-065, which is the closest downgradient well to the Cold Waste Ponds. Sulfate and total dissolved solids concentrations decrease rapidly as the distance downgradient from the Cold Waste Ponds increases. Although concentrations of sulfate and total dissolved solids are significantly higher in well USGS-065 than in the other monitoring wells, both parameters remained below the Ground Water Quality Rule Secondary Constituent Standards in well USGS-065. The facility was in compliance with the Reuse Permit during the 2016 permit year.

  19. 2015 Annual Reuse Report for the Idaho National Laboratory Site’s Advanced Test Reactor Complex Cold Waste Ponds

    Energy Technology Data Exchange (ETDEWEB)

    Lewis, Michael George [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2016-02-01

    This report describes conditions and information, as required by the state of Idaho, Department of Environmental Quality Reuse Permit I-161-02, for the Advanced Test Reactor Complex Cold Waste Ponds located at Idaho National Laboratory from November 1, 2014–October 31, 2015. The effective date of Reuse Permit I-161-02 is November 20, 2014 with an expiration date of November 19, 2019.

  20. Renewing Aristotelian Theory: The Cold Fusion Controversy as a Test Case.

    Science.gov (United States)

    Gross, Alan G.

    1995-01-01

    Exhibits the strength and flexibility of science as a rhetorical enterprise via a rhetorical analysis of cold fusion which reveals science under considerable stress. Assumes the continuing viability of classical rhetoric as an explanation for the persuasiveness of texts, while acknowledging the need to reexamine its central concepts. (SR)

  1. Thermal Vacuum Testing of ICPTA RCS at Plum Brook B-2

    Science.gov (United States)

    Atwell, M. J.; Hurlbert, E. A.; Melcher, J. C.; Morehead, R. L.

    2017-01-01

    Vacuum and thermal vacuum testing of the Integrated Cryogenic Propulsion Test Article (ICPTA) was performed at the Plum Brook B-2 facility as a part of a system checkout and facility characterization effort. Multiple test objectives included: integrated Reaction Control System (RCS) characterization, cold helium pressurization system characterization, modal propellant gaging experiment (Orion), CFM propellant loading experiments, main engine characterization. The ICPTA is a test bed for LOX/LCH4 technologies built in 2016 using new components and hardware from the former Morpheus vehicle and other projects.

  2. Does acetaminophen/hydrocodone affect cold pulpal testing in patients with symptomatic irreversible pulpitis? A prospective, randomized, double-blind, placebo-controlled study.

    Science.gov (United States)

    Fowler, Sara; Fullmer, Spencer; Drum, Melissa; Reader, Al

    2014-12-01

    The purpose of this prospective randomized, double-blind, placebo-controlled study was to determine the effects of a combination dose of 1000 mg acetaminophen/10 mg hydrocodone on cold pulpal testing in patients experiencing symptomatic irreversible pulpitis. One hundred emergency patients in moderate to severe pain diagnosed with symptomatic irreversible pulpitis of a mandibular posterior tooth randomly received, in a double-blind manner, identical capsules of either a combination of 1000 mg acetaminophen/10 hydrocodone or placebo. Cold testing with Endo-Ice (1,1,1,2 tetrafluoroethane; Hygenic Corp, Akron, OH) was performed at baseline and every 10 minutes for 60 minutes. Pain to cold testing was recorded by the patient using a Heft-Parker visual analog scale. Patients' reaction to the cold application was also rated. Cold testing at baseline and at 10 minutes resulted in severe pain for both the acetaminophen/hydrocodone and placebo groups. Although pain ratings decreased from 20-60 minutes, the ratings still resulted in moderate pain. Patient reaction to cold testing showed that 56%-62% had a severe reaction. Although the reactions decreased in severity over the 60 minutes, 20%-34% still had severe reactions at 60 minutes. Regarding pain and patients' reactions to cold testing, there were no significant differences between the combination acetaminophen/hydrocodone and placebo groups at any time period. A combination dose of 1000 mg of acetaminophen/10 mg of hydrocodone did not statistically affect cold pulpal testing in patients presenting with symptomatic irreversible pulpitis. Patients experienced moderate to severe pain and reactions to cold testing. Copyright © 2014 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  3. Cold Stress

    Science.gov (United States)

    ... Publications and Products Programs Contact NIOSH NIOSH COLD STRESS Recommend on Facebook Tweet Share Compartir Workers who ... cold environments may be at risk of cold stress. Extreme cold weather is a dangerous situation that ...

  4. Two simple systems with cold atoms: quantum chaos tests and nonequilibrium dynamics

    OpenAIRE

    Stone, Cavan; Aoud, Yassine Ait El; Yurovsky, Vladimir A; Olshanii, Maxim

    2010-01-01

    This article is an attempt to provide a link between the quantum nonequilibrium dynamics of cold gases and fifty years of progress in the lowdimensional quantum chaos. We identify two atomic systems lying on the interface: two interacting atoms in a harmonic multimode waveguide and an interacting two-component Bose-Bose mixture in a double-well potential. In particular, we study the level spacing distribution, the wavefunction statistics, the eigenstate thermalization, and the ability to ther...

  5. Study on elastic-plastic behaviour of inclusions in cold drawn wire by using reverse analysis and nanoindentation test

    Directory of Open Access Journals (Sweden)

    Lee Kyung-Hun

    2015-01-01

    Full Text Available The purpose of this study is to investigate the elastic-plastic behavior of inclusions, i.e. SiO2 particles, in cold drawn wire using reverse analysis and nanoindentation test. First, the nanoindentation tests were performed to obtain indentation load P – penetration depth h curves. Second, the reverse analysis which is consisted of various dimensionless functions including change in E∗/σr, Wp/Wt and n was used to extract the elastic-plastic properties of the indented inclusions and metals from indentation responses. To verify the accuracy of calculated properties, uniaxial tensile tests were performed for different materials which are AISI 1045 and AISI 1080. Results (E, σy, n of tensile tests for each material were also compared with those of nanoindentation tests.

  6. Two simple systems with cold atoms: quantum chaos tests and non-equilibrium dynamics

    Energy Technology Data Exchange (ETDEWEB)

    Stone, Cavan; Aoud, Yassine Ait El; Olshanii, Maxim [Department of Physics, University of Massachusetts Boston, Boston MA 02125 (United States); Yurovsky, Vladimir A, E-mail: Maxim.Olshanii@umb.ed [School of Chemistry, Tel Aviv University, 69978 Tel Aviv (Israel)

    2010-05-15

    This paper is an attempt to establish a link between the quantum nonequilibrium dynamics of cold gases and 50 years of progress in low-dimensional quantum chaos. We identify two atomic systems lying in the interface: two interacting atoms in a harmonic multimode waveguide and an interacting two-component Bose-Bose mixture in a double-well potential. In particular, we study the level spacing distribution, the wavefunction statistics, the eigenstate thermalization and the ability to thermalize in a relaxation process as such.

  7. A Systematic Review of the Empirical Support for Check-in Check-Out

    Science.gov (United States)

    Wolfe, Katie; Pyle, Daniel; Charlton, Cade T.; Sabey, Christian V.; Lund, Emily M.; Ross, Scott W.

    2016-01-01

    Tier 2 interventions play an important role within the Positive Behavioral Interventions and Supports framework, bridging the gap between schoolwide Tier 1 interventions and individualized Tier 3 supports. Check-in Check-out (CICO) is a promising Tier 2 intervention for addressing mild problem behavior and potentially preventing the need for more…

  8. Presence of Candy and Snack Food at Checkout in Chain Stores: Results of a Pilot Study.

    Science.gov (United States)

    Basch, Corey H; Kernan, William D; Menafro, Anthony

    2016-10-01

    Community health professionals must use multiple strategies to address the rising rates of childhood obesity in the United States. One such strategy is to address the underlying causes of childhood obesity, including lack of exercise and the consumption of calorically-dense snack foods. This study examines the presence of candy and snack food in the checkout lines of all retail chain stores in a selected community to determine the presence of these products, the ways in which these products are promoted, and the type of physical environment through which customers navigate during the checkout process. The findings confirm that candy, soft drinks, snacks, and ice cream were present in a large majority of these retail stores. Further, this pilot study found that many of these stores "corral" customers through the check-out line in such a way that it is necessary to pass these snack foods directly. Three themes for discussion emerged from the review of the data collected, including product marketing, product packaging, and product placement. Implications for childhood health are presented in the context of these marketing strategies. The results and subsequent discussion provide important insight into the ways in which the presence of candy and snack food at checkout lines might contribute to childhood obesity rates.

  9. Autonomic Response to the Cold Pressor Test : Through the Analysis of the Power Spectrum of the Heart Rate Variability

    OpenAIRE

    藤岩, 秀樹; 石尾, 潤; 中村, 貢治

    2010-01-01

    The purpose of this investigation is to clarify the autonomic response to the cold pressor test (CPT) by analyzing the power spectrum of the heart rate variability (HRV). The subjects of this investigation were 10 males who were aged 16-17 years. The results of this investigation are summarized as follows: 1)The parasympathetic nerve activity of the subjects decreased significantly in CPT. 2)The sympathetic nerve activity of the subjects increased significantly in CPT. 3)It is...

  10. Hypoalgesia after exercise and the cold pressor test is reduced in chronic musculuskeletal pain patients with high pain sensitivity

    DEFF Research Database (Denmark)

    Vægter, Henrik Bjarke; Handberg, Gitte; Graven-Nielsen, Thomas

    2016-01-01

    AND METHODS: On 2 days, manual pressure pain thresholds (PPTs) were recorded at the legs, arm, and shoulder in 61 chronic pain patients and they performed the cold pressor test, 2 exercise conditions (bicycling and isometric contraction), and a control condition in a randomized and counterbalanced order. PPTs...... implications as clinicians should evaluate pain sensitivity when considering treatment options utilizing the descending modulatory pain control.......OBJECTIVES: In chronic pain patients, impaired conditioned pain modulation (CPM) and exercise-induced hypoalgesia (EIH) have been reported. No studies have compared CPM and EIH in chronic musculoskeletal pain patients with high pain sensitivity (HPS) and low pain sensitivity (LPS). MATERIALS...

  11. Insulated Concrete Form Walls Integrated With Mechanical Systems in a Cold Climate Test House

    Energy Technology Data Exchange (ETDEWEB)

    Mallay, D. [Home Innovation Research Labs, Upper Marlboro, MD (United States); Wiehagen, J. [Home Innovation Research Labs, Upper Marlboro, MD (United States)

    2014-09-01

    Transitioning from standard light frame to a thermal mass wall system in a high performance home will require a higher level of design integration with the mechanical systems. The much higher mass in the ICF wall influences heat transfer through the wall and affects how the heating and cooling system responds to changing outdoor conditions. This is even more important for efficient, low-load homes with efficient heat pump systems in colder climates where the heating and cooling peak loads are significantly different from standard construction. This report analyzes a range of design features and component performance estimates in an effort to select practical, cost-effective solutions for high performance homes in a cold climate.

  12. EFFECTS OF AMLODIPIN AND METOPROLOL ON AUTONOMIC SYSTEM IN EMOTIONAL AND COLD TESTS IN HYPERTENSIVE PATIENTS WITH DIFFERENT PSYCHOLOGICAL PROFILE

    Directory of Open Access Journals (Sweden)

    M. P. Rubanova

    2006-01-01

    Full Text Available Aim. To asses effects of amlodipin and metoprolol on autonomic system in emotional and cold tests in hypertensive patients with different psychological profile (PP Material and methods. 61 patients with arterial hypertension of II grade were observed. Therapy with amlodipin or metoprolol was prescribed and allowed to reach target blood pressure (BP level in all the patients. Patients were divided into 2 groups: 1-st one – patients with normal PP, 2-nd group – patients with subclinical depression. Patients were examined before and 30 days after therapy. Examination included ambulatory BP monitoring, assessment of autonomic status by variational intervalometry and spectral analysis of heart rate variability (HRV in cold and emotional tests. Depression and anxiety levels were determined with Bek’s and HADS scales.  Results. Treatment with amlodipin  and metoprolol can result in improvement, worsening or unchanging of PP.  In hypertensive patients with subclinical depression improving their PP resulted in autonomic reaction change: sympathetic activity increases and reaction on stress becomes more adequate. If subclinical depression occurred in hypertensive patients because of amlodipin and metoprolol therapy, sympathetic system stress-reaction decreased and parasympathetic influence increased. Conclusion. The study results show necessity of psychometric examination of hypertensive patients in order to reveal subclinical depression and anxiety.  

  13. Plasma renin and cardiovascular responses to the cold pressor test differ in black and white populations: The SABPA study.

    Science.gov (United States)

    Gafane, L F; Schutte, R; Van Rooyen, J M; Schutte, A E

    2016-05-01

    Low plasma renin levels and augmented cardiovascular reactivity to stress are common in blacks and have been linked to the development of hypertension in this population. We (i) compared cardiovascular and plasma renin reactivity to a cold pressor test between a black and white population; and (ii) investigated the associations between cardiovascular and plasma renin reactivity within the black and white populations. Our population consisted of 153 black and 188 white men and women (age range, 20-65 years). We measured blood pressure (BP), heart rate (HR), stroke volume (SV), total peripheral resistance (TPR), Windkessel arterial compliance, and determined plasma renin levels at rest and during the cold pressor test. Reactivity was calculated for each participant as the percentage change from the resting value. We found lower renin and elevated BP in blacks compared with whites at rest and during stress (both, Prenin reactivity in blacks only (β=0.17; P=0.041), while in whites diastolic BP reactivity was positively associated with renin reactivity (β=0.21; P=0.005). Although blacks had suppressed renin levels at rest and during acute stress, vascular resistance reactivity associated positively with renin reactivity only in the black population. These results suggest that low renin levels in blacks during rest and stress are linked to increased peripheral vascular responses to stress, which may contribute to elevated BP in blacks.

  14. Configuration and Design of Checkout System for Reusable Launch Vehicle

    Science.gov (United States)

    Muraleedharan, A.; Mohanan Chettiar, V.; Shyamkumar, U.; Vivekanand, V.; Sandeep, C. R.; Kishorenath, V.

    2017-11-01

    The structure and concept of the reusable launch vehicle (RLV) is different from conventional satellite launch vehicles including its avionic systems architecture, which introduces new concept for power distribution and closed loop control response timings. This work describes about the systems involved in the testing of this new concept launch vehicle. The work also describes about the new avionic systems powering scheme introduced and new measurement system adopted.

  15. Common Cold

    Science.gov (United States)

    ... nose, coughing - everyone knows the symptoms of the common cold. It is probably the most common illness. In ... avoid colds. There is no cure for the common cold. For relief, try Getting plenty of rest Drinking ...

  16. Cold laboratory test on nuclide removal from Low-Level Radioactive Liquid Waste by lanthanum phosphate reduction coprecipitation method

    Energy Technology Data Exchange (ETDEWEB)

    Igarashi, T. [Nuclear Technology and Engineering Corp., Tokai, Ibaraki (Japan); Fukumoto, Masahiro; Murata, E.; Kobayashi, T.; Ikeda, Satoshi

    1999-02-01

    Low Level Radioactive Waste Treatment Facility (LWTF) for the removal of radionuclides contained in Low Level Radioactive Liquid Waste (LLLW) from reprocessing plant in JNC Tokai Works is now under construction. The primary process has now been designed to be complex processes: removal of iodine, of carbonic acid in solution, of lanthanides coprecipitated with ferric hydroxide and of remaining radionuclides such as strontium can cesium. However, the study on the behavior of ruthenium in the coprecipitation process revealed that it is insufficient for removal of ruthenium. As an alternative process, coprecipitation with lanthanum phosphate method substituting for ferric hydroxide was studied. As the result of test, it was confirmed that the method is practical to remove ruthenium with other lanthanides from LLLW except strontium. In this report, the preliminary cold test was described briefly. (H. Itami)

  17. Cold fusion

    Energy Technology Data Exchange (ETDEWEB)

    Suh, Suk Yong; Sung, Ki Woong; Kang, Joo Sang; Lee, Jong Jik [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of)

    1995-02-01

    So called `cold fusion phenomena` are not confirmed yet. Excess heat generation is very delicate one. Neutron generation is most reliable results, however, the records are erratic and the same results could not be repeated. So there is no reason to exclude the malfunction of testing instruments. The same arguments arise in recording {sup 4}He, {sup 3}He, {sup 3}H, which are not rich in quantity basically. An experiment where plenty of {sup 4}He were recorded is attached in appendix. The problem is that we are trying to search cold fusion which is permitted by nature or not. The famous tunneling effect in quantum mechanics will answer it, however, the most fusion rate is known to be negligible. The focus of this project is on the theme that how to increase that negligible fusion rate. 6 figs, 4 tabs, 1512 refs. (Author).

  18. Insulated Concrete Form Walls Integrated With Mechanical Systems in a Cold Climate Test House

    Energy Technology Data Exchange (ETDEWEB)

    Mallay, D.; Wiehagen, J.

    2014-09-01

    Transitioning from standard light frame to a thermal mass wall system in a high performance home will require a higher level of design integration with the mechanical systems. The much higher mass in the ICF wall influences heat transfer through the wall and affects how the heating and cooling system responds to changing outdoor conditions. This is even more important for efficient, low-load homes with efficient heat pump systems in colder climates where the heating and cooling peak loads are significantly different from standard construction. This report analyzes a range of design features and component performance estimates in an effort to select practical, cost-effective solutions for high performance homes in a cold climate. Of primary interest is the influence of the ICF walls on developing an effective air sealing strategy and selecting an appropriate heating and cooling equipment type and capacity. The domestic water heating system is analyzed for costs and savings to investigate options for higher efficiency electric water heating. A method to ensure mechanical ventilation air flows is examined. The final solution package includes high-R mass walls, very low infiltration rates, multi-stage heat pump heating, solar thermal domestic hot water system, and energy recovery ventilation. This solution package can be used for homes to exceed 2012 International Energy Conservation Code requirements throughout all climate zones and achieves the DOE Challenge Home certification.

  19. Paying for express checkout: competition and price discrimination in multi-server queuing systems.

    Science.gov (United States)

    Deck, Cary; Kimbrough, Erik O; Mongrain, Steeve

    2014-01-01

    We model competition between two firms selling identical goods to customers who arrive in the market stochastically. Shoppers choose where to purchase based upon both price and the time cost associated with waiting for service. One seller provides two separate queues, each with its own server, while the other seller has a single queue and server. We explore the market impact of the multi-server seller engaging in waiting cost-based-price discrimination by charging a premium for express checkout. Specifically, we analyze this situation computationally and through the use of controlled laboratory experiments. We find that this form of price discrimination is harmful to sellers and beneficial to consumers. When the two-queue seller offers express checkout for impatient customers, the single queue seller focuses on the patient shoppers thereby driving down prices and profits while increasing consumer surplus.

  20. Paying for express checkout: competition and price discrimination in multi-server queuing systems.

    Directory of Open Access Journals (Sweden)

    Cary Deck

    Full Text Available We model competition between two firms selling identical goods to customers who arrive in the market stochastically. Shoppers choose where to purchase based upon both price and the time cost associated with waiting for service. One seller provides two separate queues, each with its own server, while the other seller has a single queue and server. We explore the market impact of the multi-server seller engaging in waiting cost-based-price discrimination by charging a premium for express checkout. Specifically, we analyze this situation computationally and through the use of controlled laboratory experiments. We find that this form of price discrimination is harmful to sellers and beneficial to consumers. When the two-queue seller offers express checkout for impatient customers, the single queue seller focuses on the patient shoppers thereby driving down prices and profits while increasing consumer surplus.

  1. Extended Cold Testing of a Russian Pulsating Mixer Pump at the Oak Ridge National Laboratory, Oak Ridge, Tennessee

    Energy Technology Data Exchange (ETDEWEB)

    Lewis, BE

    2002-12-23

    The effectiveness of a mixer is dependent on the size of the tank to be mixed, the characteristics of the waste, and the operating conditions. Waste tanks throughout the U.S. Department of Energy Complex require mixing and mobilization systems capable of (1) breaking up and suspending materials that are difficult to mix and pump, without introducing additional liquids into the tank; (2) complementing and augmenting the performance of other remotely operated and/or robotic waste retrieval systems; and (3) operating in tanks with various quantities of waste. The Oak Ridge Russian pulsating mixer pump (PMP) system was designed with the flexibility to permit deployment in a variety of cylindrical tanks. The PMP was installed at the Tanks Technology Cold Test Facility at the Oak Ridge National Laboratory (ORNL) to assess the performance of the system over an extended range of operating conditions, including supply pressures up to 175 psig. Previously conducted cold tests proved the applicability of the PMP for deployment in ORNL gunite tank TH-4. The previous testing and hot demonstrations had been limited to operating at air supply pressures of <100 psig. The extended cold testing of the Russian PMP system showed that the system was capable of mobilizing waste simulants in tanks in excess of 20-ft diam. The waste simulant used in these tests was medium-grain quartz sand. The system was successfully installed, checked out, and operated for 406 pulse discharge cycles. Only minor problems (i.e., a sticking air distributor valve and a few system lockups) were noted. Some improvements to the design of the air distributor valve may be needed to improve reliability. The air supply requirements of the PMP during the discharge cycle necessitated the operation of the system in single pulse discharge cycles to allow time for the air supply reservoir to recharge to the required pressure. During the test program, the system was operated with sand depths of 2, 4, and 4.5 in.; at

  2. Automated System Checkout to Support Predictive Maintenance for the Reusable Launch Vehicle

    Science.gov (United States)

    Patterson-Hine, Ann; Deb, Somnath; Kulkarni, Deepak; Wang, Yao; Lau, Sonie (Technical Monitor)

    1998-01-01

    The Propulsion Checkout and Control System (PCCS) is a predictive maintenance software system. The real-time checkout procedures and diagnostics are designed to detect components that need maintenance based on their condition, rather than using more conventional approaches such as scheduled or reliability centered maintenance. Predictive maintenance can reduce turn-around time and cost and increase safety as compared to conventional maintenance approaches. Real-time sensor validation, limit checking, statistical anomaly detection, and failure prediction based on simulation models are employed. Multi-signal models, useful for testability analysis during system design, are used during the operational phase to detect and isolate degraded or failed components. The TEAMS-RT real-time diagnostic engine was developed to utilize the multi-signal models by Qualtech Systems, Inc. Capability of predicting the maintenance condition was successfully demonstrated with a variety of data, from simulation to actual operation on the Integrated Propulsion Technology Demonstrator (IPTD) at Marshall Space Flight Center (MSFC). Playback of IPTD valve actuations for feature recognition updates identified an otherwise undetectable Main Propulsion System 12 inch prevalve degradation. The algorithms were loaded into the Propulsion Checkout and Control System for further development and are the first known application of predictive Integrated Vehicle Health Management to an operational cryogenic testbed. The software performed successfully in real-time, meeting the required performance goal of 1 second cycle time.

  3. Cortisol and ghrelin concentrations following a cold pressor stress test in overweight individuals with and without night eating.

    Science.gov (United States)

    Geliebter, A; Carnell, S; Gluck, M E

    2013-08-01

    To explore appetite-related hormones following stress in overweight individuals, and their relationship with night eating (NE) status. We measured plasma cortisol and ghrelin concentrations, and recorded ratings of stress and hunger in response to a physiological laboratory stressor (cold pressor test, CPT), in overweight women with (n=11; NE) and without (n=17; non-NE) NE. Following the CPT, cortisol (Pstress and hunger ratings (all Pstress (Pstress. Overweight individuals showed increased cortisol, ghrelin, stress and hunger following a laboratory stressor, and there was some evidence for greater increases in cortisol and subjective stress among NE. The greater AUC cortisol level in NE was due to higher baseline levels, but the group difference in stress was in direct response to the stressor. Our results support a role for cortisol and stress in NE.

  4. Testing and design of a passive container for the optimisation of highbush blueberries (Vaccinium corymbosum L. cold chain

    Directory of Open Access Journals (Sweden)

    Roberto Beghi

    2016-06-01

    Full Text Available The aim of this work is to test a passive cooling system (PCS on highbush blueberry (Vaccinium corymbosum L. to verify cooling performances soon after harvest. Based on experimental results the cooling trend was modelled and a dedicated system was designed for the optimisation of blueberries cold chain. The evolution of qualitative characteristics of stored fruits was evaluated analysing the percentage of damaged berries, the weight loss, the texture, the titratable acidity and the total soluble solids content. The analysis of temperature profiles during transport using PCS shows how this device is not fast enough in tearing down the blueberries field heat. A computer simulation, using finite elements method modelling, considering the thermo-physical properties of materials used and the boundary conditions arising from experimental data collected was carried out. Computer modelling has provided the characteristics of geometry, thickness, type and density of the material to obtain the desired cooling performance.

  5. Fatores associados ao trabalho de operadores de checkout: investigação das queixas musculoesqueléticas Factors related to the work of checkout operators: research musculoskeletal complaints

    Directory of Open Access Journals (Sweden)

    Clarissa Stefani Teixeira

    2009-01-01

    Full Text Available Este artigo buscou verificar os fatores associados à dor musculoesquelética expressa por operadores de checkout. Participaram do estudo 48 trabalhadores que responderam ao questionário nórdico para identificação da presença de queixas musculoesqueléticas e a um questionário multidimensional com aspectos sociodemográficos de saúde e de condições de trabalho. Para a análise dos dados, foi utilizada a correlação de Spearman para associações, Qui-Quadrado e teste exato de Fisher para testar a homogeneidade das queixas em relação às variáveis socioeconômicas de saúde e de condições do trabalho. Os resultados indicam condições de trabalho não conformes com a NR-17, as quais se relacionam com os sintomas musculoesqueléticos principalmente na região superior das costas. Além disso, os afastamentos por queixas relacionaram-se de forma mais forte aos joelhos e ao exercício de outro trabalho remunerado.This article aims to evaluate the factors associated with complaints of musculoskeletal pain expressed by checkout operators. Participants in the study were 48 employees who responded to the Nordic questionnaire to identify the presence of musculoskeletal complaints, and a multidimensional questionnaire covering aspects of socio-demographics, health and working conditions. For data analysis it used Spearman's correlation to test for associations, chi-square and Fisher's Exact Test to test the homogeneity of complaints related to socioeconomic variables, health and working conditions. The results indicate a lack of compliance with the NR-17 on working conditions, and relate to musculoskeletal symptoms, especially in the upper back. Moreover, job loss due to such complaints related preponderantly to knee problems and the carrying out of other paid work.

  6. Predicted and observed growth of Listeria monocytogenes in seafood challenge tests and in naturally contaminated cold smoked salmon

    DEFF Research Database (Denmark)

    Dalgaard, Paw; Jørgensen, Lasse Vigel

    1998-01-01

    -smoked salmon. Challenge tests with both cured and noncured products were studied, and graphs as well as the bias-and the accuracy factors were used for comparison of the observed and predicted growth. The Pathogen Modelling Program could not be successfully validated in seafood challenge tests. Growth rates...... were markedly overestimated and the mu(max)-bias factor was as high as 3.9 in challenge tests with cured products. On the basis of the effect of temperature, NaCl/a(w) and pH, the mu(max)-bias factor of the other three models studied, varied between 1.0 and 2.3 in the challenge tests with cured....... Temperature, pH, NaCl/a(w) and lactate were measured in the storage trials and on the basis of these parameters, the Food MicroModel mu(max)-bias factor was 5.2. Clearly, the model could not be successfully validated with naturally contaminated cold-smoked salmon. To improve the applicability of predictive...

  7. Study of tensile test behavior of austenitic stainless steel type 347 seamless thin-walled tubes in cold worked condition

    Energy Technology Data Exchange (ETDEWEB)

    Terui, Clarice, E-mail: clarice.terui@marinha.mil.br [Centro Tecnológico da Marinha em São Paulo (CINA/CTMSP), Iperó, SP (Brazil). Centro Industrial Nuclear da Marinha; Lima, Nelson B. de, E-mail: nblima@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNE-SP), Sao Paulo, SP (Brazil)

    2017-07-01

    These austenitic stainless steel type 347 seamless thin-walled tubes are potential candidates to be used in fuel elements of nuclear power plants (as PWR - Pressurized Water Reactor). So, their metallurgical condition and mechanical properties, as the tensile strength and yield strength, normally are very restrict in demanding project and design requirements. Several full size tensile tests at room temperature and high temperature (315 deg C) were performed in these seamless tubes in cold-worked condition. The results of specified tensile and yield strengths were achieved but the elongation of the tube, in the geometry of the component, could not be measured at high temperature due to unconventional mode of rupture (helical mode without separation of parts). The average value of elongation was obtained from stress-strain curves of hot tensile tests and was around 5%. The results obtained in this research show that this behavior of the full size tensile test samples of thin-walled tube (wall thickness less than 0.5 mm) in high temperature (315°C) is due to the combination of the manufacturing process, the material (crystallographic structure and chemical composition) and the final geometry of the component. In other words, the strong crystallographic texture of material induced by tube drawing process in addition with the geometry of the component are responsible for the behavior in hot uniaxial tensile tests. (author)

  8. Reliability of Early and Final Counts in Cold and Cool Germination Tests for Predicting Maize Seed Vigour

    Directory of Open Access Journals (Sweden)

    Enrico Noli

    2010-10-01

    Full Text Available Cold test (CT is widely used in maize for predicting field performance in early sowing, even though it is rather labour intensive and requires almost two weeks to complete. The objective of this work was to examine alternative procedures to CT suitable for routine testing. Standard germination (SG, CT and cool germination (CG were carried out on 24 maize lots chosen with high (> 85% SG. For the three tests, besides the final count of normal seedlings, early counts of germinated seeds were made. Lots were evaluated in two field trials (six replicates each sowed at a very early and early date. For all the laboratory traits, the differences among lots were significant and attained higher values in the early counts compared to the final ones. Moreover, the correlations were high between early counts performed during the three tests but were in general lower between early and final counts. Early counts showed lower correlations with field performance than the final ones, except for the count at 144 h during CG that attained a correlation level with field emergence (r = 0.81 similar to the final counts of CG and CT. Nonetheless, the evaluation of seedling vigour during the final count of CT showed the highest predictive value of field performance. All the laboratory measures were in close agreement with field performance when the latter was evaluated under less unfavourable conditions.

  9. ROSA/LSTF Test and RELAP5 Analyses on PWR Cold Leg Small-Break LOCA with Accident Management Measure and PKL Counterpart Test

    Energy Technology Data Exchange (ETDEWEB)

    Takeda, Takeshi; Ohtsu, Iwao [Nuclear Safety Research Center, Japan Atomic Energy Agency, Tokaimura (Japan)

    2017-08-15

    An experiment using the Primaerkreislaeufe Versuchsanlage (PKL) was performed for the OECD/NEA PKL-3 Project as a counterpart to a previous test with the large-scale test facility (LSTF) on a cold leg small-break loss-of-coolant accident with an accident management (AM) measure in a pressurized water reactor. Concerning the AM measure, the rate of steam generator (SG) secondary-side depressurization was controlled to achieve a primary depressurization rate of 200 K/h as a common test condition; however, the onset timings of the SG depressurization were different from each other. In both tests, rapid recovery started in the core collapsed liquid level after loop seal clearing, which caused whole core quench. Some discrepancies appeared between the LSTF and PKL test results for the core collapsed liquid level, the cladding surface temperature, and the primary pressure. The RELAP5/MOD3.3 code predicted the overall trends of the major thermal-hydraulic responses observed in the LSTF test well, and indicated a remaining problem in the prediction of primary coolant distribution. Results of uncertainty analysis for the LSTF test clarified the influences of the combination of multiple uncertain parameters on peak cladding temperature within the defined uncertain ranges.

  10. Cold Testing of a Russian Pulsating Mixer Pump at the Oak Ridge National Laboratory, Oak Ridge, Tennessee

    Energy Technology Data Exchange (ETDEWEB)

    Lewis, BE

    2002-01-29

    Russian pulsating mixer pump (PMP) technology was identified in FY 1996 during technical exchanges between the U.S. Department of Energy (DOE) Tanks Focus Area Retrieval and Closure program, the DOE Environmental Management International Programs, and delegates from Russia as a technology that could be implemented in tank waste retrieval operations in the United States. The PMP is basically a jet mixer powered by a pressure/vacuum supply system. A prototype PMP was provided by the Russian Mining and Chemical Combine and evaluated as a potential retrieval tool in FY 1997 at Pacific Northwest National Laboratory (PNNL). Based on this evaluation, Oak Ridge National Laboratory (ORNL) and DOE staff determined that a modified PMP would meet project needs for bulk mobilization of sludge from one or more of the Gunite and Associated Tanks (GAAT) at ORNL. In FY 1998, PMP technology was selected for deployment in one of the GAAT to mobilize settled solids. Deployment of the PMP was expected to reduce operation and maintenance costs required to utilize more expensive retrieval systems. The following series of cold tests and inspections were conducted on one of the three PMP units provided to verify the acceptability and readiness of the mixing system for operation in the GAATs at ORNL: (1) Inspections and measurements designed to evaluate the integrity of the equipment: Fabrication shop inspections, Equipment inspections, Vibration/oscillation measurements, Hydrostatic pressure tests. (2) Functionality of the system components: Tank riser interface functionality, Decontamination spray ring (DSR) functionality, Valves, actuator, sensors, and control system functionality, Support fixture tests; and Contamination control assessment. (3) Mixing and operational performance of the PMP system: DSR performance, PMP debris tolerance, PMP performance with water only, PMP cleaning radius determination, and PMP performance with sludge surrogates. The results from these tests indicate

  11. Waterhammer Modeling for the Ares I Upper Stage Reaction Control System Cold Flow Development Test Article

    Science.gov (United States)

    Williams, Jonathan H.

    2010-01-01

    The Upper Stage Reaction Control System provides three-axis attitude control for the Ares I launch vehicle during active Upper Stage flight. The system design must accommodate rapid thruster firing to maintain the proper launch trajectory and thus allow for the possibility to pulse multiple thrusters simultaneously. Rapid thruster valve closure creates an increase in static pressure, known as waterhammer, which propagates throughout the propellant system at pressures exceeding nominal design values. A series of development tests conducted in the fall of 2009 at Marshall Space Flight Center were performed using a water-flow test article to better understand fluid performance characteristics of the Upper Stage Reaction Control System. A subset of the tests examined waterhammer along with the subsequent pressure and frequency response in the flight-representative system and provided data to anchor numerical models. This thesis presents a comparison of waterhammer test results with numerical model and analytical results. An overview of the flight system, test article, modeling and analysis are also provided.

  12. Certification Tests on Cold Patch Asphalt Repair Materials for Use in Airfield Pavements

    Science.gov (United States)

    2010-06-01

    calculating the amount of bitumen absorbed by the aggregate, and in providing target values for the compaction of pav- ing mixtures (ASTM D2041). A weighed...pavement structure consisted of 5 in. of HMA over 8 in. of limestone, 6 in. of stabilized clay gravel, 16 in. of clay gravel and, finally, the...test section. HMA Limestone Stabilized Clay Gravel Clay Gravel Subgrade 5” 8” 6” 16 ERDC/GSL TR-10-14 30 Repairs The test area

  13. Test Report for Permanganate and Cold Strontium Strike for Tank 241-AN-102

    Energy Technology Data Exchange (ETDEWEB)

    Duncan, James B.; Huber, Heinz J.; Smalley, Colleen S.

    2013-11-27

    Tanks 241-AN-102 and 241-AN-107 supernatants contain soluble Sr-90 and transuranic elements that require removal prior to vitrification to comply with the Waste Treatment and Immobilization Plant immobilized low-activity waste specification (WTP Contract, DE-AC27-01RV 14136, Specification 2.2.2.8, "Radionuclide Concentration Limitations") and the U.S. Nuclear Regulatory Commission provisional agreement on waste incidental to reprocessing (letter, Paperiello, C. J., "Classification of Hanford Low-Activity Tank Waste Fraction"). These two tanks have high concentrations of organics and organic complexants and are referred to as complexant concentrate tanks. A precipitation process using sodium permanganate (NaMnO{sub 4}) and strontium nitrate (Sr(NO{sub 3}){sub 2}) was developed and tested with tank waste samples to precipitate Sr-90 and transuranic elements from the supernate (PNWD-3141, Optimization of Sr/TRU Removal Conditions with Samples of AN-102 Tank Waste). Testing documented in this report was conducted to further evaluate the use of the strontium nitrate/sodium permanganate process in tank farms with a retention time of up to 12 months. Previous testing was focused on developing a process for deployment in the ultrafiltration vessels in the Waste Treatment and Immobilization Plant. This environment is different from tank farms in two important ways: the waste is diluted in the Waste Treatment and Immobilization Plant to ~5.5 M sodium, whereas the supernate in the tank farms is ~9 M Na. Secondly, while the Waste Treatment and Immobilization Plant allows for a maximum treatment time of hours to days, the in-tank farms treatment of tanks 241-AN102 and 241-AN-107 will result in a retention time of months (perhaps up to12 months) before processing. A comparative compilation of separation processes for Sr/transuranics has been published as RPP-RPT-48340, Evaluation of Alternative Strontium and Transuranic Separation Processes. This report also listed the testing

  14. Technology Solutions Case Study: Field Testing an Unvented Roof with Asphalt Shingles in a Cold Climate

    Energy Technology Data Exchange (ETDEWEB)

    K. Ueno and J. Lstiburek

    2015-09-01

    Test houses with unvented roof assemblies were built to measure long-term moisture performance, in the Chicago area (5A) and the Houston area (2A). The Chicago-area test bed had seven experimental rafter bays, including a "control" vented compact roof, and six unvented roof variants with cellulose or fiberglass insulation. The interior was run at 50% RH. All roofs except the vented cathedral assembly experienced wood moisture contents and RH levels high enough to constitute failure. Disassembly at the end of the experiment showed that the unvented fiberglass roofs had wet sheathing and mold growth. In contrast, the cellulose roofs only had slight issues, such as rusted fasteners and sheathing grain raise.

  15. Byggmeister Test Home: Analysis and Initial Results of Cold Climate Wood-Framed Home Retrofit

    Energy Technology Data Exchange (ETDEWEB)

    Gates, C.

    2013-01-01

    BSC seeks to further the energy efficiency market for New England area retrofit projects by supporting projects that are based on solid building science fundamentals and verified implementation. With the high exposure of energy efficiency and retrofit terminology being used in the general media at this time, it is important to have evidence that measures being proposed will in fact benefit the homeowner through a combination of energy savings, improved durability, and occupant comfort. There are several basic areas of research to which the technical report for these test homes can be expected to contribute. These include the combination of measures that is feasible, affordable and acceptable to homeowners as well as expectations versus results. Two Byggmeister multi-family test homes in Massachusetts are examined with the goal of providing case studies that could be applied to other similar New England homes.

  16. Field Testing Unvented Roofs with Asphalt Shingles in Cold and Hot-Humid Climates

    Energy Technology Data Exchange (ETDEWEB)

    Ueno, Kohta [Building Science Corporation, Westford, MA (United States); Lstiburek, Joseph W. [Building Science Corporation, Westford, MA (United States)

    2015-09-01

    Test houses with unvented roof assemblies were built to measure long-term moisture performance, in the Chicago area (5A) and the Houston area (2A). The Chicago-area test bed had seven experimental rafter bays, including a control vented compact roof, and six unvented roof variants with cellulose or fiberglass insulation. The interior was run at 50% RH. The Houston-area roof was an unvented attic insulated with spray-applied fiberglass. Most ridges and hips were built with a diffusion vent detail, capped with vapor permeable roof membrane. In contrast, the diffusion vent roofs had drier conditions at the roof peak in wintertime, but during the summer, RHs and MCs were higher than the unvented roof (albeit in the safe range).

  17. COLD-PCR enriches low-level variant DNA sequences and increases the sensitivity of genetic testing.

    Science.gov (United States)

    Castellanos-Rizaldos, Elena; Milbury, Coren A; Guha, Minakshi; Makrigiorgos, G Mike

    2014-01-01

    Detection of low-level mutations is important for cancer biomarker and therapy targets discovery, but reliable detection remains a technical challenge. The newly developed method of CO-amplification at Lower Denaturation temperature PCR (COLD-PCR) helps to circumvent this issue. This PCR-based technology preferentially enriches minor known or unknown variants present in samples with a high background of wild type DNA which often hampers the accurate identification of these minority alleles. This is a simple process that consists of lowering the temperature at the denaturation step during the PCR-cycling protocol (critical denaturation temperature, T c) and inducing DNA heteroduplexing during an intermediate step. COLD-PCR in its simplest forms does not need additional reagents or specific instrumentation and thus, can easily replace conventional PCR and at the same time improve the mutation detection sensitivity limit of downstream technologies. COLD-PCR can be applied in two basic formats: fast-COLD-PCR that can enrich T m-reducing mutations and full-COLD-PCR that can enrich all mutations, though it requires an intermediate cross-hybridization step that lengthens the thermocycling program. An improved version of full-COLD-PCR (improved and complete enrichment, ice-COLD-PCR) has also been described. Finally, most recently, we developed yet another form of COLD-PCR, temperature-tolerant-COLD-PCR, which gradually increases the denaturation temperature during the COLD-PCR reaction, enriching diverse targets using a single cycling program. This report describes practical considerations for application of fast-, full-, ice-, and temperature-tolerant-COLD-PCR for enrichment of mutations prior to downstream screening.

  18. A Cold War Battlefield: Frenchman Flat Historic District, Nevada Test Site, Nye County, Nevada

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, William Gray [DRI; Holz, Barbara A [DRI; Jones, Robert [DRI

    2000-08-01

    This report provides the U.S. Department of Energy, Nevada Operations Office with the documentation necessary to establish the Frenchman Flat Historic District on the Nevada Test Site (NTS). It includes a list of historic properties that contribute to the eligibility of the district for inclusion in the National Register of Historic Places (NRHP) and provides contextual information establishing its significance. The list focuses on buildings, structures and features associated with the period of atmospheric testing of nuclear weapons on the NTS between 1951 and 1962. A total of 157 locations of buildings and structures were recorded of which 115 are considered to be eligible for the NRHP. Of these, 28 have one or more associated features which include instrumentation supports, foundations, etc. The large majority of contributing structures are buildings built to study the blast effects of nuclear weaponry. This has resulted in a peculiar accumulation of deteriorated structures that, unlike most historic districts, is best represented by those that are the most damaged. Limitations by radiological control areas, surface exposure and a focus on the concentration of accessible properties on the dry lake bed indicate additional properties exist which could be added to the district on a case-by-case basis.

  19. Assessment of RELAP/MOD3 using BETHSY 6.2TC 6-inch cold leg side break comparative test

    Energy Technology Data Exchange (ETDEWEB)

    Chung, Young-Jong; Jeong, Jae-Jun; Chang, Won-Pyo; Kim, Dong-Su [Korea Atomic Energy Research Institute, Yusung, Taejon (Korea, Republic of)] [and others

    1996-10-01

    This report presents the results of the RELAP5/MOD3 Version 7j assessment on BETHSY 6.2TC. BETHSY 6.2TC test corresponding to a six inch cold leg break LOCA of the Pressurizer Water Reactor(PWR). The primary objective of the test was to provide reference data of two facilities of different scales (BETHSY and LSTF facility). On the other hand, the present calculation aims at analysis of RELAP5/N4OD3 capability on the small break LOCA simulation, The results of calculation have shown that the RELAP5/MOD3 reasonably predicts occurrences as well as trends of the major phenomena such as primary pressure, timing of loop seal clearing, liquid hold up, etc. However, some disagreements also have been found in the predictions of loop seal clearing, collapsed core water level after loop seal clearing, and accumulator injection behaviors. For better understanding of discrepancies in same predictions, several sensitivity calculations have been performed as well. These include the changes of two-phase discharge coefficient at the break junction and some corrections of the interphase drag term. As result, change of a single parameter has not improved the overall predictions and it has been found that the interphase drag model has still large uncertainties.

  20. Cortisol, hunger, and desire to binge eat following a cold stress test in obese women with binge eating disorder.

    Science.gov (United States)

    Gluck, Marci E; Geliebter, Allan; Hung, Jennifer; Yahav, Eric

    2004-01-01

    Increased basal cortisol levels have been found in bulimia nervosa. After stress, increased cortisol levels have been associated with increased food intake in healthy women. Therefore, we assessed cortisol, hunger, and desire to binge eat after a cold pressor test (CPT) among women with binge eating disorder (BED). Twenty-two obese (body mass index [BMI] = 36.7 +/- 6.5 SD) females (11 non-BED, 11 BED) completed the Zung depression scale and underwent the CPT, hand submerged in ice water for 2 minutes. Over 60 minutes, periodic ratings of hunger and desire to binge eat were obtained, just before blood draws for cortisol, as well as insulin. On a separate day, participants had a 1-mg oral dexamethasone suppression test (DST). The BED group had higher depression scores than the non-BED (p = .04), but depression was not a significant covariate for the cortisol response or to DST. After controlling for contraceptive use (n = 3), the BED group had higher basal cortisol than the non-BED group (p = .03), but cortisol did not differ after DST (p = .40). The BED group had nearly significant greater cortisol AUC after the CPT (p = .057) after controlling for insulin AUC and contraceptive use (p = .057). The BED group also had greater AUC for hunger (p = .03) and desire to binge eat (p = .02) after the CPT. These findings support our hypothesis of a hyperactive HPA-axis in BED, which may contribute to greater hunger and binge eating.

  1. Training of SMEs for frozen food shelf life testing and novel smart packaging application for cold chain monitoring

    Directory of Open Access Journals (Sweden)

    Theofania Tsironi

    2015-10-01

    Full Text Available  Application of an optimized cold chain management system for frozen products can be assisted by monitoring with Time Temperature Integrators (TTI. TTI are smart labels that cumulatively show the product history in an easily measurable, time-temperature dependent change. In the IQ-Freshlabel European project enzymatic and photochromic TTI were developed and tested for frozen products. Further to the technical objectives, training activities were implemented to provide information and training to the staff of Small and Medium-sized Enterprises (SMEs regarding the properties of the developed TTI and their utilization within food packaging, transport, storage and sale. In total, more than 276 European companies and consumers representing the frozen food industry, the packaging industry and food business operators were successfully trained. The objective of the present article is to describe a general methodology for frozen food shelf life testing and modelling, and the selection of appropriate TTI for specific foods. This document serves as a technical manual for SMEs, including a case study for frozen shrimp and application of enzymatic and photochromic TTI, aiming to build their capacities to understand and use TTI for frozen food products. The value of systematic modelling of the food quality kinetics as well as the response of the TTI in building an effective chill chain management system is also demonstrated. The TTI response study allows a reliable optimization and selection of TTI to be correlated to the target food product for which accurate information on temperature dependence is available.

  2. Field Testing Unvented Roofs with Asphalt Shingles in Cold and Hot-Humid Climates

    Energy Technology Data Exchange (ETDEWEB)

    Ueno, Kohta [National Renewable Energy Lab. (NREL), Golden, CO (United States); Lstiburek, Joseph W. [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2015-09-01

    Insulating roofs with dense-pack cellulose (instead of spray foam) has moisture risks, but is a lower cost approach. If moisture risks could be addressed, buildings could benefit from retrofit options, and the ability to bring HVAC systems within the conditioned space. Test houses with unvented roof assemblies were built to measure long-term moisture performance, in the Chicago area (5A) and the Houston area (2A). The Chicago-area test bed had seven experimental rafter bays, including a control vented compact roof, and six unvented roof variants with cellulose or fiberglass insulation. The interior was run at 50% RH. All roofs except the vented cathedral assembly experienced wood moisture contents and RH levels high enough to constitute failure. Disassembly at the end of the experiment showed that the unvented fiberglass roofs had wet sheathing and mold growth. In contrast, the cellulose roofs only had slight issues, such as rusted fasteners and sheathing grain raise. The Houston-area roof was an unvented attic insulated with spray-applied fiberglass. Most ridges and hips were built with a diffusion vent detail, capped with vapor permeable roof membrane. Some ridge sections were built as a conventional unvented roof, as a control. In the control unvented roofs, roof peak RHs reached high levels in the first winter; as exterior conditions warmed, RHs quickly fell. In contrast, the diffusion vent roofs had drier conditions at the roof peak in wintertime, but during the summer, RHs and MCs were higher than the unvented roof (albeit in the safe range).

  3. In vitro efficacy of cold atmospheric pressure plasma on S. sanguinis biofilms in comparison of two test models

    Directory of Open Access Journals (Sweden)

    Gorynia, Susanne

    2013-04-01

    Full Text Available [english] Dental plaque critically affects the etiology of caries, periodontitis and periimplantitis. The mechanical removal of plaque can only be performed partially due to limited accessibility. Therefore, plaque still represents one of the major therapeutic challenges. Even though antiseptic mouth rinses reduce the extent of biofilm temporarily, plaque removal remains incomplete and continuous usage can even result in side effects. Here we tested argon plasma produced by kinpen09 as one option to inactivate microorganisms and to eliminate plaque. biofilms cultivated in either the European Biofilm Reactor (EUREBI or in 24 well plates were treated with argon plasma. In both test systems a homogeneous, good analyzable and stable biofilm was produced on the surface of titan plates within 72 h (>6,9 log CFU/ml. Despite the significantly more powerful biofilm production in EUREBI, the difference of 0.4 log CFU/ml between EUREBI and the 24 well plates was practically not relevant. For that reason both test models were equally qualified for the analysis of efficacy of cold atmospheric pressure plasma. We demonstrate a significant reduction of the biofilm compared to the control in both test models. After plasma application of 180 s the biofilm produced in EUREBI or in 24 well plates was decreased by 0.6 log CFU/ml or 0.5 log CFU/ml, respectively. In comparison to recently published studies analyzing the efficacy of kinpen09, produces a hardly removable biofilm. Future investigations using reduced distances between plasma source and biofilm, various compositions of plasma and alternative plasma sources will contribute to further optimization of the efficacy against biofilms.

  4. Pilot Scale Testing of Adsorbent Amended Filters under High Hydraulic Loads for Highway Runoff in Cold Climates

    Directory of Open Access Journals (Sweden)

    Carlos Monrabal-Martinez

    2017-03-01

    Full Text Available This paper presents an estimation of the service life of three filters composed of sand and three alternative adsorbents for stormwater treatment according to Norwegian water quality standards for receiving surface waters. The study conducted pilot scale column tests on three adsorbent amended filters for treatment of highway runoff in cold climates under high hydraulic loads. The objectives were to evaluate the effect of high hydraulic loads and the application of deicing salts on the performance of these filters. From previous theoretical and laboratory analysis granulated activated charcoal, pine bark, and granulated olivine were chosen as alternative adsorbent materials for the present test. Adsorption performance of the filters was evaluated vis-à-vis four commonly found hazardous metals (Cu, Pb, Ni and Zn in stormwater. The results showed that the filters were able to pass water at high inflow rates while achieving high removal. Among the filters, the filters amended with olivine or pine bark provided the best performance both in short and long-term tests. The addition of NaCl (1 g/L did not show any adverse impact on the desorption of already adsorbed metals, except for Ni removal by the charcoal amended filter, which was negatively impacted by the salt addition. The service life of the filters was found to be limited by zinc and copper, due to high concentrations observed in local urban runoff, combined with moderate affinity with the adsorbents. It was concluded that both the olivine and the pine bark amended filter should be tested in full-scale conditions.

  5. A Comparison of Three-Dimensional Simulations of Traveling-Wave Tube Cold-Test Characteristics Using CST MICROWAVE STUDIO and MAFIA

    Science.gov (United States)

    Chevalier, C. T.; Herrmann, K. A.; Kory, C. L.; Wilson, J. D.; Cross, A. W.; Williams, W. D. (Technical Monitor)

    2001-01-01

    Previously, it was shown that MAFIA (solutions of Maxwell's equations by the Finite Integration Algorithm), a three-dimensional simulation code, can be used to produce accurate cold-test characteristics including frequency-phase dispersion, interaction impedance, and attenuation for traveling-wave tube (TWT) slow-wave structures. In an effort to improve user-friendliness and simulation time, a model was developed to compute the cold-test parameters using the electromagnetic field simulation software package CST MICROWAVE STUDIO (MWS). Cold-test parameters were calculated for several slow-wave circuits including a ferruled coupled-cavity, a folded waveguide, and a novel finned-ladder circuit using both MWS and MAFIA. Comparisons indicate that MWS provides more accurate cold-test data with significantly reduced simulation times. Both MAFIA and MWS are based on the finite integration (FI) method; however, MWS has several advantages over MAFIA. First, it has a Windows based interface for PC operation, making it very user-friendly, whereas MAFIA is UNIX based. MWS uses a new Perfect Boundary Approximation (PBA), which increases the accuracy of the simulations by avoiding stair step approximations associated with MAFIA's representation of structures. Finally, MWS includes a Visual Basic for Applications (VBA) compatible macro language that enables the simulation process to be automated and allows for the optimization of user-defined goal functions, such as interaction impedance.

  6. 2013 Annual Industrial Wastewater Reuse Report for the Idaho National Laboratory Site’s Advanced Test Reactor Complex Cold Waste Pond

    Energy Technology Data Exchange (ETDEWEB)

    Mike Lewis

    2014-02-01

    This report describes conditions, as required by the state of Idaho Industrial Wastewater Reuse Permit (#LA 000161 01, Modification B), for the wastewater land application site at the Idaho National Laboratory Site’s Advanced Test Reactor Complex Cold Waste Pond from November 1, 2012–October 31, 2013. The report contains the following information: • Facility and system description • Permit required effluent monitoring data and loading rates • Groundwater monitoring data • Status of compliance activities • Noncompliance issues • Discussion of the facility’s environmental impacts. During the 2013 permit year, approximately 238 million gallons of wastewater was discharged to the Cold Waste Pond. This is well below the maximum annual permit limit of 375 million gallons. As shown by the groundwater sampling data, sulfate and total dissolved solids concentrations are highest near the Cold Waste Pond and decrease rapidly as the distance from the Cold Waste Pond increases. Although concentrations of sulfate and total dissolved solids are elevated near the Cold Waste Pond, both parameters are below the Ground Water Quality Rule Secondary Constituent Standards in the down gradient monitoring wells.

  7. 2014 Annual Industrial Wastewater Reuse Report for the Idaho National Laboratory Site’s Advanced Test Reactor Complex Cold Waste Pond

    Energy Technology Data Exchange (ETDEWEB)

    Lewis, Mike [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2015-02-01

    This report describes conditions, as required by the state of Idaho Industrial Wastewater Reuse Permit (LA 000161 01, Modification B), for the wastewater land application site at the Idaho National Laboratory Site’s Advanced Test Reactor Complex Cold Waste Pond from November 1, 2013–October 31, 2014. The report contains the following information; Facility and system description; Permit required effluent monitoring data and loading rates; Permit required groundwater monitoring data; Status of compliance activities; Noncompliance issues; and Discussion of the facility’s environmental impacts. During the 2014 permit year, approximately 238 million gallons of wastewater were discharged to the Cold Waste Pond. This is well below the maximum annual permit limit of 375 million gallons. As shown by the groundwater sampling data, sulfate and total dissolved solids concentrations are highest near the Cold Waste Pond and decrease rapidly as the distance from the Cold Waste Pond increases. Although concentrations of sulfate and total dissolved solids are elevated near the Cold Waste Pond, both parameters are below the Ground Water Quality Rule Secondary Constituent Standards in the downgradient monitoring wells.

  8. 2011 Annual Industrial Wastewater Reuse Report for the Idaho National Laboratory Site's Advanced Test Reactor Complex Cold Waste Pond

    Energy Technology Data Exchange (ETDEWEB)

    Mike Lewis

    2012-02-01

    This report describes conditions, as required by the state of Idaho Industrial Wastewater Reuse Permit (LA 000161 01, Modification B), for the wastewater land application site at the Idaho National Laboratory Site's Advanced Test Reactor Complex Cold Waste Pond from November 1, 2010 through October 31, 2011. The report contains the following information: Facility and system description Permit required effluent monitoring data and loading rates Groundwater monitoring data Status of compliance activities Noncompliance and other issues Discussion of the facility's environmental impacts During the 2011 permit year, approximately 166 million gallons of wastewater were discharged to the Cold Waste Pond. This is well below the maximum annual permit limit of 375 million gallons. As shown by the groundwater sampling data, sulfate and total dissolved solids concentrations are highest near the Cold Waste Pond and decrease rapidly as the distance from the Cold Waste Pond increases. Although concentrations of sulfate and total dissolved solids are elevated near the Cold Waste Pond, both parameters were below the Ground Water Quality Rule Secondary Constituent Standards in the down gradient monitoring wells.

  9. 2012 Annual Industrial Wastewater Reuse Report for the Idaho National Laboratory Site's Advanced Test Reactor Complex Cold Waste Pond

    Energy Technology Data Exchange (ETDEWEB)

    Mike Lewis

    2013-02-01

    This report describes conditions, as required by the state of Idaho Industrial Wastewater Reuse Permit (#LA 000161 01, Modification B), for the wastewater land application site at the Idaho National Laboratory Site’s Advanced Test Reactor Complex Cold Waste Pond from November 1, 2011 through October 31, 2012. The report contains the following information: Facility and system description Permit required effluent monitoring data and loading rates Groundwater monitoring data Status of compliance activities Noncompliance issues Discussion of the facility’s environmental impacts During the 2012 permit year, approximately 183 million gallons of wastewater were discharged to the Cold Waste Pond. This is well below the maximum annual permit limit of 375 million gallons. As shown by the groundwater sampling data, sulfate and total dissolved solids concentrations are highest near the Cold Waste Pond and decrease rapidly as the distance from the Cold Waste Pond increases. Although concentrations of sulfate and total dissolved solids are elevated near the Cold Waste Pond, both parameters were below the Ground Water Quality Rule Secondary Constituent Standards in the down gradient monitoring wells.

  10. 2010 Annual Industrial Wastewater Reuse Report for the Idaho National Laboratory Site’s Advanced Test Reactor Complex Cold Waste Pond

    Energy Technology Data Exchange (ETDEWEB)

    mike lewis

    2011-02-01

    This report describes conditions, as required by the state of Idaho Industrial Wastewater Reuse Permit (#LA 000161 01, Modification B), for the wastewater land application site at the Idaho National Laboratory Site’s Advanced Test Reactor Complex Cold Waste Pond from November 1, 2009 through October 31, 2010. The report contains the following information: • Facility and system description • Permit required effluent monitoring data and loading rates • Groundwater monitoring data • Status of compliance activities • Discussion of the facility’s environmental impacts During the 2010 permit year, approximately 164 million gallons of wastewater were discharged to the Cold Waste Pond. As shown by the groundwater sampling data, sulfate and total dissolved solids concentrations are highest near the Cold Waste Pond and decrease rapidly as the distance from the Cold Waste Pond increases. Although concentrations of sulfate and total dissolved solids are elevated near the Cold Waste Pond, both parameters were below the Ground Water Quality Rule Secondary Constituent Standards in the down gradient monitoring wells.

  11. Plasma cortisol levels in response to a cold pressor test did not predict appetite or ad libitum test meal intake in obese women.

    Science.gov (United States)

    Geliebter, Allan; Gibson, Charlisa D; Hernandez, Dominica B; Atalayer, Deniz; Kwon, Anne; Lee, Michelle I; Mehta, Nandini; Phair, Donna; Gluck, Marci E

    2012-12-01

    Heightened cortisol response to stress due to hyperactivation of the hypothalamic-pituitary-adrenal (HPA) axis may stimulate appetite and food intake. In this study, we assessed cortisol responsivity to a cold pressor test (CPT) as well as appetite ratings and subsequent test meal intake (TMI) in obese women. Following an overnight fast on two counterbalanced days, 20 obese women immersed their non-dominant hand for 2min in ice water (CPT) or warm water (WW) as a control. Plasma cortisol (ng/ml), heart rate, and blood pressure, as well as ratings of stress, pain, and appetite, were serially acquired. An ad libitum liquid meal was offered at 45min and intake measured covertly. Fasting cortisol was higher at 15min (mean peak cortisol) following the CPT compared to WW. Higher stress was reported at 2 and 15min for the CPT compared to WW. Pain, an indirect marker of the acute stress, systolic and diastolic blood pressure increased following the CPT at 2min compared to WW. Hunger decreased after the CPT at 2 and 15min, and desire to eat ratings were lower following CPT compared to WW. Subjects did not have greater test meal intake (TMI) following CPT compared to WW. There was also no significant relationship between cortisol levels following stress and TMI, indicating that cortisol did not predict subsequent intake in obese women. Copyright © 2012 Elsevier Ltd. All rights reserved.

  12. Cardiovascular responses during cold pressor test are different in Parkinson disease and multiple system atrophy with parkinsonism.

    Science.gov (United States)

    Roy, Sankanika; Srivastava, Achal Kumar; Jaryal, Ashok Kumar; Deepak, Kishore Kumar

    2015-08-01

    Orthostatic hypotension (OH) is common in Parkinson disease (PD) and multiple system atrophy of parkinsonian type (MSA-P), but the pathophysiology of OH is different in the two. We hypothesised that the baroreflex-independent sympathetic reactivity may also be different in them. To evaluate this we assessed the sympathetic vascular reactivity and the heart rate response to the standard cold pressor test (CPT) in these patients. The study was conducted in ten patients with PD with OH, 5 PD without OH, 13 MSA-P with OH, and 7 MSA-P without OH. Lead II ECG and finger PPG (photoplethysmography) were simultaneously acquired during a baseline period of 1 min followed by a 10 °C cold exposure (1 min) of the contralateral hand (CPT). The vascular response was then evaluated by computing the pulse transit time (PTT). The percentage decrease in PTT during the CPT was significantly higher in patients with PD as compared to MSA-P, irrespective of the presence or absence of OH (-2.74 ± 0.96 vs -0.05 ± 0.75 %, p = 0.03; PD vs MSA-P with OH and -3.04 ± 0.85 vs 0.48 ± 1.13 %, p = 0.04; PD vs MSA-P without OH). The rise in heart rate during CPT was similar in patients with PD and MSA-P with or without OH (4.95 ± 1.6 vs 5.99 ± 1.04, p = 0.28; PD vs MSA-P with OH and 5.62 ± 1.31 vs 13.15 ± 2.89, p = 0.06; PD vs MSA-P without OH). Vasoconstrictor response to CPT is compromised in MSA-P as compared to PD, but the baroreflex-independent heart rate response is similar in the two.

  13. Final report on a cold climate permeable interlocking concrete pavement test facility at the University of New Hampshire Stormwater Center.

    Science.gov (United States)

    2013-05-01

    University of New Hampshire Stormwater Center (UNHSC) completed a two year field verification study of a permeable interlocking concrete pavement (PICP) stormwater management system. The purpose of this study was to evaluate the cold climate function...

  14. Testing of different soil combinations as substrates in slalom slopes and golf courses in the cold climate environment

    Science.gov (United States)

    Pihlaja, Jouni

    2010-05-01

    Testing of different soil combinations as substrates in slalom slopes and golf courses in the cold climate environment Jouni Pihlaja, Geological Survey of Finland, Northern Finland Office, P.O. Box 77, FIN-96101 Rovaniemi, Finland. jouni.pihlaja@gtk.fi, www.gtk.fi The Geological Survey of Finland (GTK) is, with some partners, carrying out a cooperative project, POMARA, in the Levi tourist center in northern Finland. The purpose of this applied geology project is to determine which soil combinations work best over the long term as substrates on slalom slopes and golf course areas. Since the tourist center is located in a cold climate area, it gives extra challenges to those landscaping activities. The average temperature in January is about -15°C and in July +14°C. In the Levi area, the slalom slopes have normally been covered by local carex peat during the shaping phase of slopes. The problem has been that on the top part of the fell, the peat has "disappeared" after some years and stones have come up under the peat layer, since these areas are naturally covered by block fields. The main assumption at the beginning of the project was that frost weathering is causing the problems. In this project, test areas have been prepared on the slopes. The most important task is to compare test areas covered by carex peat to areas covered by a combination of sandy till and carex peat. The reason why sandy till was chosen to be the additional material was that it is supposed to stand up better against frost weathering than peat itself. Also, when considering future landscaping, the sandy till is the most economically viable mineral material to be used because of its nearby location . In the golf course areas, a combination of fine sand and sphagnum peat has been used in landscaping. The peat was brought from the Simo area, 300 km south of Levi. In this project, the goal is to determine if the local carex peat is working properly in the green areas of the golf club. The

  15. Methods of Evaluating Protective Clothing Relative to Heat and Cold Stress: Thermal Manikin, Biomedical Modeling, and Human Testing

    Science.gov (United States)

    2011-01-01

    1996. pp. 419–438. 47. O’Brien, C., A.J. Young, and M.N. Sawka: Hypohydration and thermoregulation in cold air. J. Appl. Physiol. 84:185–189 (1998...code) 2011 Journal Article-Journal of Occup and Env Hygiene Methods of Evaluating Protective Clothing Relative to Heat and cold Stress: Thermal...hazard assessment, thermal strain, thermoregulation Unclassified Unclassified Unclassified Unclassified 12 Catherine O’Brien 508-233-5973 Reset Journal

  16. Thermal math model analysis of FRSI test article subjected to cold soak and entry environments. [Flexible Reuseable Surface Insulation in Space Shuttle Orbiter

    Science.gov (United States)

    Gallegos, J. J.

    1978-01-01

    A multi-objective test program was conducted at the NASA/JSC Radiant Heat Test Facility in which an aluminum skin/stringer test panel insulated with FRSI (Flexible Reusable Surface Insulation) was subjected to 24 simulated Space Shuttle Orbiter ascent/entry heating cycles with a cold soak in between in the 10th and 20th cycles. A two-dimensional thermal math model was developed and utilized to predict the thermal performance of the FRSI. Results are presented which indicate that the modeling techniques and property values have been proven adequate in predicting peak structure temperatures and entry thermal responses from both an ambient and cold soak condition of an FRSI covered aluminum structure.

  17. Detection of cold pain, cold allodynia and cold hyperalgesia in freely behaving rats

    Directory of Open Access Journals (Sweden)

    Woolf Clifford J

    2005-12-01

    Full Text Available Abstract Background Pain is elicited by cold, and a major feature of many neuropathic pain states is that normally innocuous cool stimuli begin to produce pain (cold allodynia. To expand our understanding of cold induced pain states we have studied cold pain behaviors over a range of temperatures in several animal models of chronic pain. Results We demonstrate that a Peltier-cooled cold plate with ± 1°C sensitivity enables quantitative measurement of a detection withdrawal response to cold stimuli in unrestrained rats. In naïve rats the threshold for eliciting cold pain behavior is 5°C. The withdrawal threshold for cold allodynia is 15°C in both the spared nerve injury and spinal nerve ligation models of neuropathic pain. Cold hyperalgesia is present in the spared nerve injury model animals, manifesting as a reduced latency of withdrawal response threshold at temperatures that elicit cold pain in naïve rats. We also show that following the peripheral inflammation produced by intraplantar injection of complete Freund's adjuvant, a hypersensitivity to cold occurs. Conclusion The peltier-cooled provides an effective means of assaying cold sensitivity in unrestrained rats. Behavioral testing of cold allodynia, hyperalgesia and pain will greatly facilitate the study of the neurobiological mechanisms involved in cold/cool sensations and enable measurement of the efficacy of pharmacological treatments to reduce these symptoms.

  18. The impact of a cold pressor test on brachial artery handgrip exercise-induced flow-mediated dilation.

    Science.gov (United States)

    Stuckless, Troy J R; Pyke, Kyra E

    2015-10-01

    It is unknown how endothelial-dependent flow-mediated dilation (FMD) stimulated by a sustained, exercise-induced increase in shear stress (EX-FMD) is affected by a simultaneous sympathoexcitatory painful stimulus. The purpose of this study was to examine the impact of a cold pressor test (CPT) on brachial artery EX-FMD elicited by a handgrip exercise-induced increase in shear stress. Participants were healthy males (age 21±2 years) (n=28; 16 Experimental group, 12 Control). Brachial artery diameter and blood velocity were measured using echo and Doppler ultrasound, respectively. Shear stress was estimated by shear rate (shear rate = blood velocity / diameter) and targeted to reach 75 s(-1) in each of two EX-FMD trials in all subjects. In the Experimental group, the second EX-FMD trial was accompanied by simultaneous foot immersion in ice water (simultaneous CPT). The shear rate stimulus did not differ between groups (p=0.823) or trials (p=0.726) (group × trial interaction: p=0.646) (average exercise shear rate (mean ± SD): 67.6±6.2 s(-1)). The CPT (experienced during EX-FMD trial 2 in the Experimental group) increased mean arterial pressure (pgroup. %EX-FMD was not different between groups (p=0.508) or trials (p=0.592) (group × trial interaction: p=0.879) (EX-FMD: Experimental group trial 1: 5.4±3.4%, trial 2: 5.6±2.6%; Control group trial 1: 6.0±3.7%, trial 2: 6.4±2.2%). In conclusion, the CPT did not impact concurrent EX-FMD, and this indicates that an acute painful stimulus does not interfere with conduit artery FMD responses during exercise in young healthy men. © The Author(s) 2015.

  19. Cold plate

    Energy Technology Data Exchange (ETDEWEB)

    Marroquin, Christopher M.; O' Connell, Kevin M.; Schultz, Mark D.; Tian, Shurong

    2018-02-13

    A cold plate, an electronic assembly including a cold plate, and a method for forming a cold plate are provided. The cold plate includes an interface plate and an opposing plate that form a plenum. The cold plate includes a plurality of active areas arranged for alignment over respective heat generating portions of an electronic assembly, and non-active areas between the active areas. A cooling fluid flows through the plenum. The plenum, at the non-active areas, has a reduced width and/or reduced height relative to the plenum at the active areas. The reduced width and/or height of the plenum, and exterior dimensions of cold plate, at the non-active areas allow the non-active areas to flex to accommodate surface variations of the electronics assembly. The reduced width and/or height non-active areas can be specifically shaped to fit between physical features of the electronics assembly.

  20. An analysis of the number of parking bays and checkout counters for a supermarket using SAS simulation studio

    Science.gov (United States)

    Kar, Leow Soo

    2014-07-01

    Two important factors that influence customer satisfaction in large supermarkets or hypermarkets are adequate parking facilities and short waiting times at the checkout counters. This paper describes the simulation analysis of a large supermarket to determine the optimal levels of these two factors. SAS Simulation Studio is used to model a large supermarket in a shopping mall with car park facility. In order to make the simulation model more realistic, a number of complexities are introduced into the model. For example, arrival patterns of customers vary with the time of the day (morning, afternoon and evening) and with the day of the week (weekdays or weekends), the transport mode of arriving customers (by car or other means), the mode of payment (cash or credit card), customer shopping pattern (leisurely, normal, exact) or choice of checkout counters (normal or express). In this study, we focus on 2 important components of the simulation model, namely the parking area, the normal and express checkout counters. The parking area is modeled using a Resource Pool block where one resource unit represents one parking bay. A customer arriving by car seizes a unit of the resource from the Pool block (parks car) and only releases it when he exits the system. Cars arriving when the Resource Pool is empty (no more parking bays) leave without entering the system. The normal and express checkouts are represented by Server blocks with appropriate service time distributions. As a case study, a supermarket in a shopping mall with a limited number of parking bays in Bangsar was chosen for this research. Empirical data on arrival patterns, arrival modes, payment modes, shopping patterns, service times of the checkout counters were collected and analyzed to validate the model. Sensitivity analysis was also performed with different simulation scenarios to identify the parameters for the optimal number the parking spaces and checkout counters.

  1. Food at checkouts in non-food stores: a cross-sectional study of a large indoor shopping mall.

    Science.gov (United States)

    Wright, James; Kamp, Erin; White, Martin; Adams, Jean; Sowden, Sarah

    2015-10-01

    To investigate the display of food at non-food store checkouts; and to classify foods by type and nutrient content, presence of price promotions and whether food was at child height. Cross-sectional survey of checkout displays at non-food stores. Foods were classified as 'less healthy' or healthier using the UK Food Standards Agency's Nutrient Profile Model. Written price promotions were recorded. Child height was defined as the sight line of an 11-year-old approximated from UK growth charts. A large indoor shopping mall, Gateshead, UK, February-March 2014. Two hundred and five out of 219 non-food stores in the shopping mall directory which were open for trading. Thirty-two (15·6%) of 205 non-food stores displayed food at the checkout. All displayed less healthy foods, and fourteen (43·8%) had healthier foods. Overall, 5911 checkout foods were identified. Of these, 4763 (80·6%) were 'less healthy'. No fruits, vegetables, nuts or seeds were found. Of 4763 less healthy foods displayed, 195 (4·1%) were subject to price promotions, compared with twelve of 1148 (1·0%) healthier foods (χ 2(df=1)=25·4, Pstores displayed checkout food, the majority of which was 'less healthy' and displayed at child height. Less healthy food was more likely to be subject to a written price promotion than healthier food. Further research into the drivers and consequences of checkout food in non-food stores is needed. Public health regulation may be warranted.

  2. Results of molten salt panel and component experiments for solar central receivers: Cold fill, freeze/thaw, thermal cycling and shock, and instrumentation tests

    Energy Technology Data Exchange (ETDEWEB)

    Pacheco, J.E.; Ralph, M.E.; Chavez, J.M.; Dunkin, S.R.; Rush, E.E.; Ghanbari, C.M.; Matthews, M.W.

    1995-01-01

    Experiments have been conducted with a molten salt loop at Sandia National Laboratories in Albuquerque, NM to resolve issues associated with the operation of the 10MW{sub e} Solar Two Central Receiver Power Plant located near Barstow, CA. The salt loop contained two receiver panels, components such as flanges and a check valve, vortex shedding and ultrasonic flow meters, and an impedance pressure transducer. Tests were conducted on procedures for filling and thawing a panel, and assessing components and instrumentation in a molten salt environment. Four categories of experiments were conducted: (1) cold filling procedures, (2) freeze/thaw procedures, (3) component tests, and (4) instrumentation tests. Cold-panel and -piping fill experiments are described, in which the panels and piping were preheated to temperatures below the salt freezing point prior to initiating flow, to determine the feasibility of cold filling the receiver and piping. The transient thermal response was measured, and heat transfer coefficients and transient stresses were calculated from the data. Freeze/thaw experiments were conducted with the panels, in which the salt was intentionally allowed to freeze in the receiver tubes, then thawed with heliostat beams. Slow thermal cycling tests were conducted to measure both how well various designs of flanges (e.g., tapered flanges or clamp type flanges) hold a seal under thermal conditions typical of nightly shut down, and the practicality of using these flanges on high maintenance components. In addition, the flanges were thermally shocked to simulate cold starting the system. Instrumentation such as vortex shedding and ultrasonic flow meters were tested alongside each other, and compared with flow measurements from calibration tanks in the flow loop.

  3. Análise comparativa de processos de serviço : sistemas de check-out

    OpenAIRE

    Almeida, Maria de Fátima Pereira de

    2010-01-01

    O presente trabalho, tem como objectivo principal contribuir para a compreensão das motivações e critérios associados ao uso de processos alternativos de serviço. Em particular, neste estudo são analisadas comparativamente duas alternativas de serviço no contexto específico da grande distribuição de retalho: sistemas de check-out tradicional e sistemas de check-out de livre serviço. O trabalho pretende aportar um contributo para a temática do desenho de processos de serviço,...

  4. Short-term test-retest-reliability of conditioned pain modulation using the cold-heat-pain method in healthy subjects and its correlation to parameters of standardized quantitative sensory testing.

    Science.gov (United States)

    Gehling, Julia; Mainka, Tina; Vollert, Jan; Pogatzki-Zahn, Esther M; Maier, Christoph; Enax-Krumova, Elena K

    2016-08-05

    Conditioned Pain Modulation (CPM) is often used to assess human descending pain inhibition. Nine different studies on the test-retest-reliability of different CPM paradigms have been published, but none of them has investigated the commonly used heat-cold-pain method. The results vary widely and therefore, reliability measures cannot be extrapolated from one CPM paradigm to another. Aim of the present study was to analyse the test-retest-reliability of the common heat-cold-pain method and its correlation to pain thresholds. We tested the short-term test-retest-reliability within 40 ± 19.9 h using a cold-water immersion (10 °C, left hand) as conditioning stimulus (CS) and heat pain (43-49 °C, pain intensity 60 ± 5 on the 101-point numeric rating scale, right forearm) as test stimulus (TS) in 25 healthy right-handed subjects (12females, 31.6 ± 14.1 years). The TS was applied 30s before (TSbefore), during (TSduring) and after (TSafter) the 60s CS. The difference between the pain ratings for TSbefore and TSduring represents the early CPM-effect, between TSbefore and TSafter the late CPM-effect. Quantitative sensory testing (QST, DFNS protocol) was performed on both sessions before the CPM assessment. paired t-tests, Intraclass correlation coefficient (ICC), standard error of measurement (SEM), smallest real difference (SRD), Pearson's correlation, Bland-Altman analysis, significance level p test-retest-reliability of the early CPM-effect using the heat-cold-pain method in healthy subjects achieved satisfying results in terms of the ICC. The SRD of the early CPM effect showed that an individual change of > 20 NRS can be attributed to a real change rather than chance. The late CPM-effect was weaker and not reliable.

  5. Cold Sore

    Science.gov (United States)

    ... pain Headache Cold sore Symptoms & causes Diagnosis & treatment Advertisement Mayo Clinic does not endorse companies or products. ... a Job Site Map About This Site Twitter Facebook Google YouTube Pinterest Mayo Clinic is a not- ...

  6. Cold Urticaria

    Science.gov (United States)

    ... management of physical urticaria. Annals of Allergy, Asthma & Immunology. 2013;111:235. Nov. 21, 2014 Original article: http://www.mayoclinic.org/diseases-conditions/cold-urticaria/basics/definition/CON-20034524 . Mayo Clinic Footer Legal Conditions ...

  7. Substituting sugar confectionery with fruit and healthy snacks at checkout – a win-win strategy for consumers and food stores? a study on consumer attitudes and sales effects of a healthy supermarket intervention

    Directory of Open Access Journals (Sweden)

    Lise L. Winkler

    2016-11-01

    Full Text Available Abstract Background The widespread use of in-store marketing strategies to induce unhealthy impulsive purchases has implications for shopping experience, food choice and possibly adverse health outcomes. The aim of this study was to examine consumer attitudes and evaluate sales effects of a healthy checkout supermarket intervention. The study was part of Project Sundhed & Lokalsamfund (Project SoL; a Danish participatory community-based health promotion intervention. Methods Consumer attitudes towards unhealthy snack exposure in supermarkets were examined in a qualitative pre-intervention study (29 short in-store interviews, 11 semi-structured interviews and three focus group interviews. Findings were presented to food retailers and informed the decision to test a healthy checkout intervention. Sugar confectionery at one checkout counter was substituted with fruit and healthy snacking items in four stores for 4 weeks. The intervention was evaluated by 48 short exit interviews on consumer perceptions of the intervention and by linear mixed model analyses of supermarket sales data from the intervention area and a matched control area. Results The qualitative pre-intervention study identified consumer concern and annoyance with placement and promotion of unhealthy snacks in local stores. Store managers were willing to respond to local consumer concern and a healthy checkout intervention was therefore implemented. Exit interviews found positive attitudes towards the intervention, while intervention awareness was modest. Most participants believed that the intervention could help other consumers make healthier choices, while fewer expected to be influenced by the intervention themselves. Statistical analyses suggested an intervention effect on sales of carrot snack packs when compared with sales before the intervention in Bornholm control stores (P < 0.05. No significant intervention effect on sales of other intervention items or sugar

  8. Substituting sugar confectionery with fruit and healthy snacks at checkout - a win-win strategy for consumers and food stores? a study on consumer attitudes and sales effects of a healthy supermarket intervention.

    Science.gov (United States)

    Winkler, Lise L; Christensen, Ulla; Glümer, Charlotte; Bloch, Paul; Mikkelsen, Bent E; Wansink, Brian; Toft, Ulla

    2016-11-22

    The widespread use of in-store marketing strategies to induce unhealthy impulsive purchases has implications for shopping experience, food choice and possibly adverse health outcomes. The aim of this study was to examine consumer attitudes and evaluate sales effects of a healthy checkout supermarket intervention. The study was part of Project Sundhed & Lokalsamfund (Project SoL); a Danish participatory community-based health promotion intervention. Consumer attitudes towards unhealthy snack exposure in supermarkets were examined in a qualitative pre-intervention study (29 short in-store interviews, 11 semi-structured interviews and three focus group interviews). Findings were presented to food retailers and informed the decision to test a healthy checkout intervention. Sugar confectionery at one checkout counter was substituted with fruit and healthy snacking items in four stores for 4 weeks. The intervention was evaluated by 48 short exit interviews on consumer perceptions of the intervention and by linear mixed model analyses of supermarket sales data from the intervention area and a matched control area. The qualitative pre-intervention study identified consumer concern and annoyance with placement and promotion of unhealthy snacks in local stores. Store managers were willing to respond to local consumer concern and a healthy checkout intervention was therefore implemented. Exit interviews found positive attitudes towards the intervention, while intervention awareness was modest. Most participants believed that the intervention could help other consumers make healthier choices, while fewer expected to be influenced by the intervention themselves. Statistical analyses suggested an intervention effect on sales of carrot snack packs when compared with sales before the intervention in Bornholm control stores (P confectionery was found. The present study finds that the healthy checkout intervention was positively evaluated by consumers and provided a 'responsible

  9. Generalized Test Plan for the Vitrification of Simulated High-Level -Waste Calcine in the Idaho National Laboratory‘s Bench -Scale Cold Crucible Induction Melter

    Energy Technology Data Exchange (ETDEWEB)

    Vince Maio

    2011-08-01

    This Preliminary Idaho National Laboratory (INL) Test Plan outlines the chronological steps required to initially evaluate the validity of vitrifying INL surrogate (cold) High-Level-Waste (HLW) solid particulate calcine in INL's Cold Crucible Induction Melter (CCIM). Its documentation and publication satisfies interim milestone WP-413-INL-01 of the DOE-EM (via the Office of River Protection) sponsored work package, WP 4.1.3, entitled 'Improved Vitrification' The primary goal of the proposed CCIM testing is to initiate efforts to identify an efficient and effective back-up and risk adverse technology for treating the actual HLW calcine stored at the INL. The calcine's treatment must be completed by 2035 as dictated by a State of Idaho Consent Order. A final report on this surrogate/calcine test in the CCIM will be issued in May 2012-pending next fiscal year funding In particular the plan provides; (1) distinct test objectives, (2) a description of the purpose and scope of planned university contracted pre-screening tests required to optimize the CCIM glass/surrogate calcine formulation, (3) a listing of necessary CCIM equipment modifications and corresponding work control document changes necessary to feed a solid particulate to the CCIM, (4) a description of the class of calcine that will be represented by the surrogate, and (5) a tentative tabulation of the anticipated CCIM testing conditions, testing parameters, sampling requirements and analytical tests. Key FY -11 milestones associated with this CCIM testing effort are also provided. The CCIM test run is scheduled to be conducted in February of 2012 and will involve testing with a surrogate HLW calcine representative of only 13% of the 4,000 m3 of 'hot' calcine residing in 6 INL Bin Sets. The remaining classes of calcine will have to be eventually tested in the CCIM if an operational scale CCIM is to be a feasible option for the actual INL HLW calcine. This remaining calcine

  10. Pain modulation as a function of hypnotizability: Diffuse noxious inhibitory control induced by cold pressor test vs explicit suggestions of analgesia.

    Science.gov (United States)

    Fidanza, Fabrizia; Varanini, Maurizio; Ciaramella, Antonella; Carli, Giancarlo; Santarcangelo, Enrica L

    2017-03-15

    The aim of the present study was to compare the effects of explicit suggestions of analgesia and of the activation of the Diffuse Noxious Inhibitory Control (DNIC) by cold pressor test on pain perception and heart rate in healthy participants with high (highs, N=18), low (lows, N=18) and intermediate scores of hypnotizability (mediums, N=15) out of hypnosis. Pain reports and the stimulus-locked heart rate changes induced by electrical nociceptive stimulation of the left hand were studied in the absence of concomitant stimuli (Control), during suggestions of analgesia (SUGG, glove analgesia) and during cold pressor test used as a conditioning stimulus to the right hand (DNIC, water temperature=10-12°C) in the REAL session. Participants were submitted also to a SHAM session in which the DNIC water temperature was 30°C and the suggestions for analgesia were substituted with weather forecast information. Both suggestions and DNIC reduced pain significantly in all subjects; however, the percentage of reduction was significantly larger in highs (pain intensity=55% of the control condition) than in mediums (70%) and lows (80%) independently of the REAL/SHAM session and of the specific pain manipulation. Heart rate was not modulated consistently with pain experience. Findings indicate that both suggestions and DNIC influence pain experience as a function of hypnotizability and suggest that both sensory and cognitive mechanisms co-operate in DNIC induced analgesia. Copyright © 2017 Elsevier Inc. All rights reserved.

  11. Cold fusion

    Energy Technology Data Exchange (ETDEWEB)

    Seo, Suk Yong; You, Jae Jun [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of)

    1996-01-01

    Nearly every technical information is chased in the world. All of them are reviewed and analyzed. Some of them are chosen to study further more to review every related documents. And a probable suggestion about the excitonic process in deuteron absorbed condensed matter is proposed a way to cold fusion. 8 refs. (Author).

  12. Common cold

    Science.gov (United States)

    ... many health problems, including colds. DO NOT use antibiotics if they are not needed. Breastfeed infants if possible. Breast milk is known to protect against respiratory tract infections in children, even years after you stop breastfeeding. Drink plenty of fluids to help your immune ...

  13. Cold Regions Environmental Considerations

    Science.gov (United States)

    2009-02-03

    MONITOR’S ACRONYM(S) 9. SPONSORING/ MONITORING AGENCY NAME(S) AND ADDRESS(ES) Test Business Management Division (TEDT-TMB) US Army Developmental...losses in dry air, decreased thirst, cold-induced diuresis , and conscious under-drinking. 12 TOP 1-1-017 03 February 2009 4.4 Shelter. A

  14. Design and testing of a separate-type lighting system using solar energy and cold-cathode fluorescent lamps

    Energy Technology Data Exchange (ETDEWEB)

    Yang, J.-P. [Department of Electrical Engineering, China Institute of Technology, Taipei, Taiwan 115, Taiwan (China)]. E-mail: april4120@tp.edu.tw; Hsiao, H.-C. [Department of Electrical Engineering, National Taiwan University of Science and Technology, Taipei, Taiwan 106, Taiwan (China)]. E-mail: hsiao@mouse.ee.ntust.edu.tw

    2007-01-15

    This paper presents a solar-powered lighting system, using cold-cathode fluorescent-lamps (CCFLs), with its battery-charging circuit and lamp-ignition circuit being separated so that its solar panels can be installed at any distance deemed necessary away from the lighting site in order to receive the maximum solar energy available. This system adopts the maximum-power point tracking (MPPT) method to control the power output of the solar panels and uses the zero-voltage switching (ZVS) DC-DC converter, as the charging circuit, to increase the panels' power generation efficiency and the charging circuit's conversion efficiency. The electronic ballast circuit for the CCFL is constructed with a half-bridge inverter, a resonant inductor, and a Rosen-type piezoelectric transformer, which forms a piezoelectric resonant-type inverter: to simplify the circuitry and to improve the power conversion efficiency, the ballast circuit is designed to directly step up the battery voltage in igniting the lamp. We also establish the transmission-parameter model for the piezoelectric resonant-type inverter to provide the base for the electric-power circuit design. Our experimental results indicate that the proposed system possesses some advantages, such as greater energy efficiency, circuitry simplicity, and so on, and is suitable for night lighting in house yards, parks and advertising panels.

  15. Coping with Cold Sores

    Science.gov (United States)

    ... Skating Living With Stepparents Be a Green Kid Cold Sores KidsHealth > For Kids > Cold Sores Print A ... sore." What's that? Adam wondered. What Is a Cold Sore? Cold sores are small blisters that is ...

  16. THE CIRCUMGALACTIC MEDIUM OF MASSIVE GALAXIES AT z {approx} 3: A TEST FOR STELLAR FEEDBACK, GALACTIC OUTFLOWS, AND COLD STREAMS

    Energy Technology Data Exchange (ETDEWEB)

    Shen Sijing; Madau, Piero; Prochaska, J. Xavier [Department of Astronomy and Astrophysics, University of California, 1156 High Street, Santa Cruz, CA 95064 (United States); Guedes, Javiera [Institute for Astronomy, ETH Zurich, Wolgang-Pauli-Strasse 27, CH-8093 Zurich (Switzerland); Mayer, Lucio [Institute of Theoretical Physics, University of Zurich, Winterthurerstrasse 190, CH-9057 Zurich (Switzerland); Wadsley, James [Department of Physics and Astronomy, McMaster University, Hamilton, ON L8S 4M1 (Canada)

    2013-03-10

    We present new results on the kinematics, thermal and ionization state, and spatial distribution of metal-enriched gas in the circumgalactic medium (CGM) of massive galaxies at redshift {approx}3, using the Eris suite of cosmological hydrodynamic ''zoom-in'' simulations. The reference run adopts a blastwave scheme for supernova feedback that produces large-scale galactic outflows, a star formation recipe based on a high gas density threshold, metal-dependent radiative cooling, and a model for the diffusion of metals and thermal energy. The effect of the local UV radiation field is added in post-processing. The CGM (defined as all gas at R > 0.2 R{sub vir} = 10 kpc, where R{sub vir} is the virial radius) contains multiple phases having a wide range of physical conditions, with more than half of its heavy elements locked in a warm-hot component at T > 10{sup 5} K. Synthetic spectra, generated by drawing sightlines through the CGM, produce interstellar absorption-line strengths of Ly{alpha}, C II, C IV, Si II, and Si IV as a function of the galactocentric impact parameter (scaled to the virial radius) that are in broad agreement with those observed at high redshift by Steidel et al. The covering factor of absorbing material declines less rapidly with impact parameter for Ly{alpha} and C IV compared to C II, Si IV, and Si II, with Ly{alpha} remaining strong (W{sub Ly{alpha}} > 300 mA) to {approx}> 5 R{sub vir} = 250 kpc. Only about one third of all the gas within R{sub vir} is outflowing. The fraction of sightlines within one virial radius that intercept optically thick, N{sub H{sub I}}>10{sup 17.2} cm{sup -2} material is 27%, in agreement with recent observations by Rudie et al. Such optically thick absorption is shown to trace inflowing ''cold'' streams that penetrate deep inside the virial radius. The streams, enriched to metallicities above 0.01 solar by previous episodes of star formation in the main host and in nearby

  17. A postura no trabalho dos operadores de checkout de supermercados: uma necessidade constante de análises Supermarket checkout operators posture at work: The continuous need for analysis

    Directory of Open Access Journals (Sweden)

    Eduardo Concepción Batiz

    2009-04-01

    Full Text Available As condições de trabalho nas quais os operadores de checkout de supermercados realizam suas atividades têm sido uma preocupação dos especialistas nos últimos tempos. Essa pesquisa foi realizada em oito supermercados de duas cidades do Brasil com o objetivo de conhecer as condições em que os operadores realizam suas atividades, detectando os fatores de risco para propor medidas que eliminem ou minimizem o aparecimento de efeitos adversos nos trabalhadores. Foi aplicado um questionário e o método RULA a uma amostra de 80 trabalhadores. O estudo mostrou que o mobiliário não está adaptado às características antropométricas da população, a maioria das posturas analisadas é inadequada, não existem revezamento nem pausas que poderiam ajudar a minimizar a situação, existência de sobrecarga, mental e física, entre outras. Conclui-se que a atividade pode representar riscos à saúde dos operadores de caixa de supermercados.The work conditions in which supermarket checkout operators perform activities have been a recent concern to specialists. This research was carried out in eight supermarkets of two cities in Brazil with the aim of knowing the conditions under which operators work, in order to detect risk factors and to propose procedures that could eliminate or minimize their adverse effects on workers. Structured questionnaire and the RULA method was applied to a sample of 80 workers. Major findings of the study as follows: furniture was not adapted to anthropometric characteristics of the workers, most of analyzed positions are not adequate, there was no rotation or pauses that could reduce the risk, there was a significant amount of mental and physical work overload. We conclude that, under current conditions, checkout operations at supermarkets poses health risk to operators.

  18. A feasibility study on different NDT techniques used for testing bond quality in cold roll bonded Al-Sn alloy/steel bimetal strips

    Directory of Open Access Journals (Sweden)

    Tallafuss Philipp Johannes

    2017-01-01

    Full Text Available This paper presents non-destructive testing (NDT results for the detection of bond defects in aluminium-tin (Al-Sn alloy/steel bimetal strips. Among all types of bimetal strip that are used in the automotive industry for plain journal engine bearings, Al-Sn alloys cold roll bonded (CRB onto steel backing is the most common type. The difficulty to evaluate the metallurgical bond between the two dissimilar metals is a major industrial concern, which comprises the risk that bearings fail in the field. Considering the harsh performance requirements, 100% online non-destructive testing would be desirable to significantly reduce the business risk. Nowadays bimetal strip manufacturers still rely on destructive testing through different peel-off tests. This work offers the results from four independent NDT studies, using active thermography, shearography, ultrasound and guided wave electromagnetic acoustic transducers (EMATs and samples with different artificially implanted defects, to explore the feasibility to qualitatively indicate the occurrence of bond defects. A destructive peel off test was used to correlate the NDT results with known bond quality. The studies were done under laboratory conditions, and in case of ultrasound also online under production conditions. During the ultrasound online test, the requirements that a NDT technique has to fulfil for online inspection of Al-Sn alloy/steel bimetal strip were established. For active thermography, shearography and guided wave EMAT techniques, it was theoretically analysed, if the laboratory test results could be transferred to testing under production conditions. As a result, guided waves using EMATs, among the four tested methods, are best suited for online inspection of Al-Sn alloy/steel bimetal strip. This research was carried out in collaboration with MAHLE Engine Systems UK Ltd., an Al-Sn alloy/steel bimetal strip manufacturer for the automotive industry.

  19. Evaluation of mini-VIDAS rapid test for detection of Listeria monocytogenes from production lines of fresh to cold-smoked fish.

    Science.gov (United States)

    Vaz-Velho, M; Duarte, G; Gibbs, P

    2000-04-01

    This study was conducted to evaluate the efficacy of the mini-VIDAS Listeria monocytogenes (LMO) system (BioMérieux Vitek, Inc., Missouri, USA) for detection of L. monocytogenes in environmental and fish samples from three Portuguese cold-smoking plants and from their fresh fish suppliers. Mini-VIDAS-LMO is a fully automated system that uses fluorescent ELFA (Enzyme Linked Fluorescent Assay) technology for detection of Listeria monocytogenes antigens in food. It can be a rapid screening method alternative to time consuming classical isolation and identification. Two hundred and ninety five samples were tested in mini-VIDAS-LMO and in parallel by the ISO 11290-1 traditional protocol. The mini-VIDAS-LMO detected 8 of the 11 confirmed positive samples and presented 11 false positive results. The specificity of the mini-VIDAS-LMO found in this experiment was 0.96 and the sensitivity 0.73.

  20. Cold Test Results of the LARP HQ Nb3Sn Quadrupole Magnet at 1.9 K

    CERN Document Server

    Bajas, H; Anerella, M; Bajko, M; Bossert, R; Caspi, S; Chiuchiolo, A; Chlachidze, G; Dietderich, D; Dunkel, O; Felice, H; Ferracin, P; Feuvrier, J; Fiscarelli, L; Ghosh, A; Giloux, C; Godeke, A; Hafalia, A; Marchevsky, M; Russenschuck, S; Sabbi, G; Salmi, T; Schmalzle, J; Todesco, E; Wanderer, P; Wang, X; Yu, M

    2013-01-01

    The HQ magnet is a 120 mm aperture, 1-meter-long Nb3Sn quadrupole developed by the LARP collaboration in support of the High-Luminosity LHC project. Several tests were performed at LBNL in 2010-2011 achieving a maximum gradient of 170 T/m at 4.4 K. As a next step in the program, the latest model (HQ01e) was sent to CERN for testing at 1.9 K. As part of this test campaign, the magnet training has been done up to a maximum current of 16.2 kA corresponding to 85 % of the short sample limit. The ramp rate dependence of the quench current is also identified. The efficiency of the quench heaters is then studied at 4.2 K and at 1.9 K. The analyses of the magnet resistance evolution during fast current discharge showed evidence of quench whereas high energy quenches have been successfully achieved and sustained with no dump resistor.

  1. Automated Break-Out Box for use with Low Cost Spacecraft Integration and Test Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Electrical checkout and testing is a critical part of the overall spacecraft integration and test flow. Verifying proper harness and connector signal interfaces is...

  2. Reuse fo a Cold War Surveillance Drone to Flight Test a NASA Rocket Based Combined Cycle Engine

    Science.gov (United States)

    Brown, T. M.; Smith, Norm

    1999-01-01

    Plans for and early feasibility investigations into the modification of a Lockheed D21B drone to flight test the DRACO Rocket Based Combined Cycle (RBCC) engine are discussed. Modifications include the addition of oxidizer tanks, modern avionics systems, actuators, and a vehicle recovery system. Current study results indicate that the D21B is a suitable candidate for this application and will allow demonstrations of all DRACO engine operating modes at Mach numbers between 0.8 and 4.0. Higher Mach numbers may be achieved with more extensive modification. Possible project risks include low speed stability and control, and recovery techniques.

  3. Building America Case Study: Field Testing an Unvented Roof with Asphalt Shingles in a Cold Climate, Boilingbrook, Illinois

    Energy Technology Data Exchange (ETDEWEB)

    2015-09-01

    Insulating roofs with dense-pack cellulose (instead of spray foam) has moisture risks, but is a lower cost approach. If moisture risks could be addressed, buildings could benefit from retrofit options, and the ability to bring HVAC systems within the conditioned space. Test houses with unvented roof assemblies were built to measure long-term moisture performance, in the Chicago area (5A) and the Houston area (2A). The Chicago-area test bed had seven experimental rafter bays, including a 'control' vented compact roof, and six unvented roof variants with cellulose or fiberglass insulation. The interior was run at 50% RH. All roofs except the vented cathedral assembly experienced wood moisture contents and RH levels high enough to constitute failure. Disassembly at the end of the experiment showed that the unvented fiberglass roofs had wet sheathing and mold growth. In contrast, the cellulose roofs only had slight issues, such as rusted fasteners and sheathing grain raise. The Houston-area roof was an unvented attic insulated with spray-applied fiberglass. Most ridges and hips were built with a 'diffusion vent' detail, capped with vapor permeable roof membrane. Some ridge sections were built as a conventional unvented roof, as a control. In the control unvented roofs, roof peak RHs reached high levels in the first winter; as exterior conditions warmed, RHs quickly fell. In contrast, the diffusion vent roofs had drier conditions at the roof peak in wintertime, but during the summer, RHs and MCs were higher than the unvented roof (albeit in the safe range).

  4. Cold symptoms (image)

    Science.gov (United States)

    Colds are caused by a virus and can occur year-round. The common cold generally involves a runny nose, nasal congestion, and ... symptoms include sore throat, cough, and headache. A cold usually lasts about 7 days, with perhaps a ...

  5. Cough & Cold Medicine Abuse

    Science.gov (United States)

    ... to Your Parents - or Other Adults Cough & Cold Medicine Abuse KidsHealth > For Teens > Cough & Cold Medicine Abuse ... resfriado Why Do People Use Cough and Cold Medicines to Get High? There's an ingredient in many ...

  6. Cold antihydrogen and CPT

    CERN Document Server

    Gabrielse, G; Bowden, N S; Oxley, P; Storry, C H; Wessels, M; Speck, A K; Estrada, J; Yesley, P S; Grzonka, D; Oelert, Walter; Schepers, G; Sefzick, T; Walz, J

    2002-01-01

    Progress in the quest for cold antihydrogen includes the first substantial accumulation of cold positrons and the first demonstration of positron cooling. Stacking of cold antiprotons is key to using the new antiproton decelerator facility at CERN. (22 refs).

  7. Cold stratification, but not stratification in salinity, enhances seedling ...

    African Journals Online (AJOL)

    Cold stratification was reported to release seed dormancy and enhance plant tolerance to salt stress. Experiments were conducted to test the hypothesis that cold stratification and cold stratification in salinity could enhance seedling growth of wheat under salt treatment. The results clearly demonstrated that cold stratification ...

  8. Cold neutron interferometry

    Science.gov (United States)

    Kitaguchi, Masaaki

    2009-10-01

    Neutron interferometry is a powerful technique for studying fundamental physics. A large dimensional interferometer for long wavelength neutrons is extremely important in order to investigate problems of fundamental physics, including tests of quantum measurement theories and searches for non-Newtonian effects of gravitation, since the sensitivity of interferometer depends on the wavelength and the interaction length. Neutron multilayer mirrors enable us to develop the large scale interferometer for long wavelength neutrons. The multilayer mirror is one of the most useful devices in cold neutron optics. A multilayer of two materials with different potentials is understood as a one-dimensional crystal, which is suitable for Bragg reflection of long wavelength neutrons. Cold and very cold neutrons can be utilized for the interferometer by using the multilayer mirrors with the proper lattice constants. Jamin-type interferometer by using beam splitting etalons (BSEs) has shown the feasibility of the development of large scale interferometer, which enables us to align the four independent mirrors within required precision. The BSE contains two parallel multilayer mirrors. A couple of the BSEs in the Jamin-type interferometer separates and recombines the two paths spatially. Although the path separation was small at the first test, now we have already demonstrated the interferometer with perfectly separated paths. This has confirmed that the multilayer mirrors cause no serious distortion of wave front to compose a interferometer. Arranging such mirrors, we are capable of establishing even a Mach-Zehnder type with much larger size. The interferometer using supermirrors, which reflects the wide range of the wavelength of neutrons, can increase the neutron counts for high precision measurements. We are planning the experiments using the interferometer both for the very cold neutrons and for the pulsed neutrons including J-PARC.

  9. TRADITIONAL GAMES RESULTED IN POST-EXERCISE HYPOTENSION AND A LOWER CARDIOVASCULAR RESPONSE TO THE COLD PRESSOR TEST IN HEALTHY CHILDREN

    Directory of Open Access Journals (Sweden)

    Suliane Beatriz Rauber

    2014-06-01

    Full Text Available The present study aimed to verify if blood pressure (BP reactivity could be reduced through a previous single session of active playing when compared to sedentary leisure. Sixteen pre-pubertal healthy children participated in this study. After familiarization with procedures and anthropometric evaluation, participants performed three sessions in randomized order: 1 30 min of traditional Brazilian games (PLAY; 2 30 min of video game playing (DDR; and 3 30 min of watching TV (TV. Each session lasted ~80 minutes, being 10 min of rest; 30 min of intervention activity; and 40 min of recovery. After recovery, the Cold Pressor Test (CPT was used for the assessment of acute cardiovascular reactivity. Blood Pressure (BP was recorded at 30 s and 1 min during the CPT. Analysis of variance showed post-exercise hypotension (PEH only after PLAY, and that systolic and diastolic BP were significantly increased in all conditions during CPT. However, the magnitude of the CPT-induced blood pressure response was significantly less in PLAY compared to DDR and TV. The PEH observed during recovery and the reduced BP response to CPT following playing traditional games may be due its higher cardiovascular and metabolic demand as was indicated by the increased heart rate, oxygen consumption, and blood pressure. It was concluded that BP reactivity to stress may be reduced through a previous single session of traditional games and that PEH was recorded only after this exercise form. This benefit indicates a potential role of playing strategies for cardiovascular health in childhood.

  10. Traditional games resulted in post-exercise hypotension and a lower cardiovascular response to the cold pressor test in healthy children.

    Science.gov (United States)

    Rauber, Suliane B; Boullosa, Daniel A; Carvalho, Ferdinando O; de Moraes, José F V N; de Sousa, Ioranny R C; Simões, Herbert G; Campbell, Carmen S G

    2014-01-01

    The present study aimed to verify if blood pressure (BP) reactivity could be reduced through a previous single session of active playing when compared to sedentary leisure. Sixteen pre-pubertal healthy children participated in this study. After familiarization with procedures and anthropometric evaluation, participants performed three sessions in randomized order: (1) 30 min of traditional Brazilian games (PLAY); (2) 30 min of video game playing (DDR); and (3) 30 min of watching TV (TV). Each session lasted 80 min, being 10 min of rest; 30 min of intervention activity; and 40 min of recovery. After recovery, the Cold Pressor Test (CPT) was used for the assessment of acute cardiovascular reactivity. BP was recorded at 30 s and 1 min during the CPT. Analysis of variance showed post-exercise hypotension (PEH) only after PLAY, and that systolic and diastolic BP were significantly increased in all conditions during CPT. However, the magnitude of the CPT-induced BP response was significantly less in PLAY compared to DDR and TV. The PEH observed during recovery and the reduced BP response to CPT following playing traditional games may be due its higher cardiovascular and metabolic demand as was indicated by the increased heart rate, oxygen consumption, and BP. It was concluded that BP reactivity to stress may be reduced through a previous single session of traditional games and that PEH was recorded only after this exercise form. This benefit indicates a potential role of playing strategies for cardiovascular health in childhood.

  11. The Basic Cardiovascular Responses to Postural Changes, Exercise, and Cold Pressor Test: Do They Vary in Accordance with the Dual Constitutional Types of Ayurveda?

    Directory of Open Access Journals (Sweden)

    Piyush Kumar Tripathi

    2011-01-01

    Full Text Available According to Ayurveda, the native Indian system of healthcare, three Doshas, namely, Vata, Pitta, and Kapha, are the basic mutually reciprocal mechanisms that are responsible for the maintenance of homeostasis in human beings. Ayurveda classifies entire human population into seven constitutional types (Prakriti, based on the dominance of any single or a combination of two or three Doshas. Considering the fact that, in the recent past there have been several studies that have proposed some important genetic, biochemical and haematological bases for Prakriti, we conducted the present study in 90 randomly selected clinically healthy volunteers belonging to dual constitutional types (Dvandvaja Prakriti to evaluate the variability of heart rate and arterial blood pressure in response to specific postural changes, exercise, and cold pressor test. The results of this study, in general, suggest that these basic cardiovascular responses do not vary significantly as per the dual constitutional types. However, we noted a significant fall in the diastolic blood pressure immediately after performing the isotonic exercise for five minutes, in Vata-Kapha individuals in comparison to the other two groups, namely, Pitta-Kapha and Vata-Pitta.

  12. Cold energy

    Science.gov (United States)

    Wallace, John P.

    2015-12-01

    Deviations in Q for resonant superconducting radio frequency niobium accelerator cavities are generally correlated with resistivity loss mechanisms. Field dependent Qs are not well modeled by these classical loss mechanisms, but rather can represent a form of precision cavity surface thermometry. When the field dependent Q variation shows improvement with increasing B field level the classical treatment of this problem is inadequate. To justify this behavior hydrogen as a ubiquitous impurity in niobium, which creates measurable property changes, even at very low concentrations is typically considered the cause of such anomalous behavior. This maybe the case in some instances, but more importantly any system operating with a highly coherent field with a significant time dependent magnetic component at near 2° K will have the ability to organize the remaining free spins within the London penetration depth to form a coupled energy reservoir in the form of low mass spin waves. The niobium resonant cavities are composed of a single isotope with a large nuclear spin. When the other loss mechanisms are stripped away this may be the gain medium activated by the low level residual magnetic fields. It was found that one resonant cavity heat treatment produced optimum surface properties and then functioned as a MASER extracting energy from the 2° K thermal bath while cooling the cavity walls. The cavity operating in this mode is a simulator of what can take place in the wider but not colder universe using the cosmic microwave background (CMB) as a thermal source. The low mass, long lifetimes, and the scale of the magnetic spin waves on the weakly magnetized interstellar medium allows energy to be stored that is many orders of magnitude colder than the cosmic microwave background. A linear accelerator cavity becomes a tool to explore the properties of the long wave length magnetic spin waves that populate this cold low energy regime.

  13. INEL cold test pit demonstration of improvements in information derived from non-intrusive geophysical methods over buried waste sites. Phase 2, Final report

    Energy Technology Data Exchange (ETDEWEB)

    1994-04-29

    Under Contract between US DOE Idaho National Engineering Laboratory (INEL) and the Blackhawk Geosciences Division of Coleman Research Corporation (BGD-CRC), geophysical investigations were conducted to improve the detection of buried wastes. Site characterization is a costly and time consuming process with the most costly components being drilling, sampling, and chemical analysis of samples. There is a focused effort at US DOE and other agencies to investigate methodologies that reduce costs and shorten the time between characterization and clean-up. These methodologies take the form of employing non-invasive (geophysical) and minimal invasive (e.g., cone penetrometer driving) techniques of characterization, and implementing a near real-time, rational decision-making process (Expedited Site Characterization). Over the Cold Test Pit (CTP) at INEL, data were acquired with multiple sensors on a dense grid. Over the CTP the interpretations inferred from geophysical data are compared with the known placement of various waste forms in the pit. The geophysical sensors employed were magnetics, frequency and time domain electromagnetics, and ground penetrating radar. Also, because of the high data density acquired, filtering and other data processing and imaging techniques were tested. The conclusions derived from the geophysical surveys were that pit boundaries, berms between cells within the pit, and individual objects placed in the pit were best mapped by the new Geonics EM61 time domain EM metal detector. Part of the reason for the effectiveness of the time domain metal detector is that objects buried in the pit are dominantly metallic. Also, the utility of geophysical data is significantly enhanced by dimensional and 3-dimensional imaging formats. These images will particularly assist remediation engineers in visualizing buried wastes.

  14. Component Testing for Modular Pier Replacement at McMurdo Station, Antarctica: Inflatable Pontoons, Gelbo Flex and Full-Scale Cold Storage/Fold Tests

    Science.gov (United States)

    2014-08-01

    tests on vulcanized samples of the composite neoprene-on-nylon pontoon fabric bonded to the neoprene- coated compound with added aramid milled fiber ...compound with added ara- mid milled fiber (commonly referred to as a gum sheet), Mil-C-14505, by itself and as a compound material vulcanized to the...Pontoon-3 LMCS fabric −40 2.75 440 1510 Leaked at 510 cycles Fiber -1 Gum sheet −40 2.75 440 1 Tear at grip Fiber -2 Gum sheet −40 2.75 440 1 Tear

  15. Cold Stowage Flight Systems

    Science.gov (United States)

    Campana, Sharon E.; Melendez, David T.

    2011-01-01

    The International Space Station (ISS) provides a test bed for researchers to perform science experiments in a variety of fields, including human research, life sciences, and space medicine. Many of the experiments being conducted today require science samples to be stored and transported in a temperature controlled environment. NASA provides several systems which aid researchers in preserving their science. On orbit systems provided by NASA include the Minus Eighty Laboratory freezer for ISS (MELFI), Microgravity Experiment Research Locker Incubator (MERLIN), and Glacier. These freezers use different technologies to provide rapid cooling and cold stowage at different temperature levels on board ISS. Systems available to researchers during transportation to and from ISS are MERLIN, Glacier, and Coldbag. Coldbag is a passive cold stowage system that uses phase change materials to maintain temperature. Details of these current technologies are provided along with operational experience gained to date. This paper discusses the capability of the current cold stowage hardware and how it may continue to support NASA s mission on ISS and in future exploration missions.

  16. Cold Urticaria

    Science.gov (United States)

    ... Mayo Foundation for Medical Education and Research; 2017. Lang DM, et al. Contemporary approaches to the diagnosis ... Lifestyle Symptoms A-Z Diseases & Conditions A-Z Tests & Procedures A-Z Drugs & Supplements A-Z Appointments ...

  17. Experimental Testing of Innovative Cold-Formed "GEB" Section / Badania Eksperymentalne Innowacyjnego Kształtownika Giętego Na Zimno Typu "Geb"

    Science.gov (United States)

    Łukowicz, Agnieszka; Urbańska-Galewska, Elżbieta; Gordziej-Zagórowska, Małgorzata

    2015-03-01

    One of the major advantages of light gauge steel structures made of cold-formed steel sections is their low weight so the production of typical single-storey steel structures of this kind of profiles is still rising. The well known profiles, e.o. Z-sections, C-sections and the so called hat-sections studied and described in the literature, are used mainly as purlins or truss components. A new profile GEB was patented for the use for primary load-bearing member in fabricated steel frames. According to the code [1] every novel cross section should be tested to assign the deformation shape and bearing capacity. The paper deals with the numerical and experimental research of bearing capacity of cold formed GEB profiles. The deformation shape and limit load was obtained from bending tests. The GEB cross section bearing capacity was also determined according to codes [1, 2]. Jedną z najważniejszych zalet lekkich konstrukcji metalowych, wytwarzanych z kształtowników giętych na zimno, jest ich mała masa, dlatego też, producenci coraz częściej wykorzystują możliwości profili giętych do wytwarzania typowych konstrukcji halowych w budownictwie systemowym. Proces gięcia na zimno, pozwala na formowanie różnego rodzaju przekrojów poprzecznych, które mogą być wykorzystywane jako elementy konstrukcji. Typowe kształty elementów. tzn. Z, C oraz tzw. przekroje kapeluszowe, które zostały przebadane i opisane w literaturze, wykorzystuje się głównie jako płatwie lub części składowe wiązarów kratowych. Nowo opatentowany przekrój typu GEB ma być wykorzystany jako element nośny konstrukcji ramowych. W związku z tym innowacyjny kształt oraz parametry geometryczne przekroju takiego kształtownika, związane z możliwością jego wyprodukowania oraz z warunkami nośności, stateczności oraz sztywności, muszą być optymalne. Według normy PN-EN 1993-1-3, każdy nowo uformowany przekrój powinien być przebadany pod kątem nośności elementu i formy

  18. Detection of diminished response to cold pressor test in smokers: assessment using phase-contrast cine magnetic resonance imaging of the coronary sinus.

    Science.gov (United States)

    Kato, Shingo; Kitagawa, Kakuya; Yoon, Yeonyee E; Nakajima, Hiroshi; Nagata, Motonori; Takase, Shinichi; Nakamori, Shiro; Ito, Masaaki; Sakuma, Hajime

    2014-04-01

    The purposes of this study were to evaluate the reproducibility for measuring the cold pressor test (CPT)-induced myocardial blood flow (MBF) alteration using phase-contrast (PC) cine MRI, and to determine if this approach could detect altered MBF response to CPT in smokers. After obtaining informed consent, ten healthy male non-smokers (mean age: 28±5 years) and ten age-matched male smokers (smoking duration ≥5 years, mean age: 28±3 years) were examined in this institutional review board approved study. Breath-hold PC cine MR images of the coronary sinus were obtained with a 3T MR imager with 32 channel coils at rest and during a CPT performed after immersing one foot in ice water. MBF was calculated as coronary sinus flow divided by the left ventricular (LV) mass which was given as a total LV myocardial volume measured on cine MRI multiplied by the specific gravity (1.05 g/mL). In non-smokers, MBF was 0.86±0.25 mL/min/g at rest, with a significant increase to 1.20±0.36 mL/min/g seen during CPT (percentage change of MBF (∆MBF (%)); 39.2%±14.4%, pcine MRI can be used to reproducibly quantify MBF response to CPT and to detect impaired flow response in smokers. This MR approach may be useful for monitoring the sequential change of coronary blood flow in various potentially pathologic conditions and for investigating its relationship with cardiovascular risk. Copyright © 2014 Elsevier Inc. All rights reserved.

  19. Cold Signaling and Cold Response in Plants

    OpenAIRE

    Kenji Miura; Tsuyoshi Furumoto

    2013-01-01

    Plants are constantly exposed to a variety of environmental stresses. Freezing or extremely low temperature constitutes a key factor influencing plant growth, development and crop productivity. Plants have evolved a mechanism to enhance tolerance to freezing during exposure to periods of low, but non-freezing temperatures. This phenomenon is called cold acclimation. During cold acclimation, plants develop several mechanisms to minimize potential damages caused by low temperature. Cold respons...

  20. [Cold-induced urticaria and angioedema. Classification, diagnosis and therapy].

    Science.gov (United States)

    Krause, K; Degener, F; Altrichter, S; Ardelean, E; Kalogeromitros, D; Magerl, M; Metz, M; Siebenhaar, F; Weller, K; Maurer, M

    2010-09-01

    The onset of wheals and/or angioedema following the exposure to cold may be associated with a number of different diseases. Most frequently this occurs in cold contact urticaria, a type of physical urticaria, which is characterized by a positive cold stimulation test. The clinical symptoms are based on cold-dependent mast cell activation with subsequent release of proinflammatory mediators. In cases of negative or atypical reaction to cold stimulation testing rare acquired atypical or familiar cold urticaria forms may be suspected. Strict avoidance of cold should be recommended as far as possible. As the underlying causes of cold contact urticaria are widely unknown, the symptomatic use of non-sedating antihistamines is the treatment of first choice. The very rare familiar cold auto-inflammatory syndrome (FCAS) is based on CIAS1/NLRP3 mutations and may be treated effectively by neutralization of pathogenic interleukin 1beta.

  1. Underage alcohol-purchasing strategies and alcohol availability through self-checkout lanes in supermarkets

    NARCIS (Netherlands)

    van Hoof, Joris Jasper

    2017-01-01

    Background: To prevent alcohol availability through retail, legal age limits forbid the sale of alcohol to minors in many countries. This study tested the effects of minors’ alcohol-purchasing strategies and knowledge of compliance with age-limit legislation on the availability of alcohol through

  2. Spectroscopy with cold and ultra-cold neutrons

    Science.gov (United States)

    Abele, Hartmut; Jenke, Tobias; Konrad, Gertrud

    2015-05-01

    We present two new types of spectroscopy methods for cold and ultra-cold neutrons. The first method, which uses the R×B drift effect to disperse charged particles in a uniformly curved magnetic field, allows to study neutron β-decay. We aim for a precision on the 10-4 level. The second method that we refer to as gravity resonance spectroscopy (GRS) allows to test Newton's gravity law at short distances. At the level of precision we are able to provide constraints on any possible gravity-like interaction. In particular, limits on dark energy chameleon fields are improved by several orders of magnitude.

  3. Spectroscopy with cold and ultra-cold neutrons

    OpenAIRE

    Abele Hartmut; Jenke Tobias; Konrad Gertrud

    2014-01-01

    We present two new types of spectroscopy methods for cold and ultra-cold neutrons. The first method, which uses the \\RB drift effect to disperse charged particles in a uniformly curved magnetic field, allows to study neutron $\\beta$-decay. We aim for a precision on the 10$^{-4}$ level. The second method that we refer to as gravity resonance spectroscopy (GRS) allows to test Newton's gravity law at short distances. At the level of precision we are able to provide constraints on any possible gr...

  4. Spectroscopy with cold and ultra-cold neutrons

    Directory of Open Access Journals (Sweden)

    Abele Hartmut

    2015-01-01

    Full Text Available We present two new types of spectroscopy methods for cold and ultra-cold neutrons. The first method, which uses the R×B drift effect to disperse charged particles in a uniformly curved magnetic field, allows to study neutron β-decay. We aim for a precision on the 10−4 level. The second method that we refer to as gravity resonance spectroscopy (GRS allows to test Newton’s gravity law at short distances. At the level of precision we are able to provide constraints on any possible gravity-like interaction. In particular, limits on dark energy chameleon fields are improved by several orders of magnitude.

  5. Axon reflexes in human cold exposed fingers

    NARCIS (Netherlands)

    Daanen, H.A.M.; Ducharme, M.B.

    2000-01-01

    Exposure of fingers to severe cold induces cold induced vasodilation (CIVD). The mechanism of CIVD is still debated. The original theory states that an axon reflex causes CIVD. To test this hypothesis, axon reflexes were evoked by electrical stimulation of the middle fingers of hands immersed in

  6. Evaluation of Cold Tolerance in Field Grown Mentha (Mentha piperita‎‏ L.‎ under ‎Laboratory Conditions by Electrolyte Leakage Test

    Directory of Open Access Journals (Sweden)

    T Kheirkhah

    2015-09-01

    Full Text Available In order to determine cold tolerance of field grown Mentha (Mentha Piperita L. under controlled conditions, using electrolyte leakage index, an experiment was carried out at the College of Agriculture, Ferdowsi University of Mashhad, based on a completely randomized design with four replications. Experimental factors included six freezing temperatures (Zero, -4, -8, -12, -16 and -20 °C, seven harvest ‎time (November, December, January, February, March, April and May and ‎four Peppermint organs (leaves, Stems, Stolons and Rhizomes. So, field grown ‎and acclimated Pepermint was harvested from the faculty field every month. ‎After separating the Peppermint organs, they were subjected to freezing ‎temperatures. The membrane stability index was measured through ‎electrolyte leakage (EL and also lethal temperature 50 ‎according to EL (LT50el was determined. The results showed that electrolyte leakages were affected significantly by freezing temperature. By reduction of freezing temperature electrolyte leakages percentage increased. Among different organs of peppermint, stolon and leaf were the most cold tolerant and the most cold sensitive according to EL and LT50el , respectively. Also cold tolerance varied according to different harvest time in all organs. However, in May, all organs had lowest cold tolerance. Also leaves and stolons had the highest and the lowest LT50el, respectively. For all organs the highest LT50el‎ was observed in May. According to the high correlation between electrolyte leakages percent and LT50el (r = 0.96**, it seems that using this index for evaluation of freezing tolerance injury in Mentha piperita could be useful.

  7. Cold wave lotion poisoning

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/article/002693.htm Cold wave lotion poisoning To use the sharing features on this page, please enable JavaScript. Cold wave lotion is a hair care product used ...

  8. Paroxysmal cold hemoglobinuria (PCH)

    Science.gov (United States)

    ... page: //medlineplus.gov/ency/article/000557.htm Paroxysmal cold hemoglobinuria (PCH) To use the sharing features on this page, please enable JavaScript. Paroxysmal cold hemoglobinuria (PCH) is a rare blood disorder in ...

  9. Cold-induced metabolism

    NARCIS (Netherlands)

    van Marken Lichtenbelt, W.D.; Daanen, A.M.

    2003-01-01

    Cold-induced metabolism. van Marken Lichtenbelt WD, Daanen HA. Department of Human Biology, Maastricht University, Maastricht, The Netherlands. PURPOSE OF REVIEW: Cold response can be insulative (drop in peripheral temperature) or metabolic (increase in energy expenditure). Nonshivering

  10. Conceptualizing Cold Disasters

    DEFF Research Database (Denmark)

    Lauta, Kristian Cedervall; Dahlberg, Rasmus; Vendelø, Morten Thanning

    2017-01-01

    In the present article, we explore in more depth the particular circumstances and characteristics of governing what we call ‘cold disasters’, and thereby, the paper sets out to investigate how disasters in cold contexts distinguish themselves from other disasters, and what the implications hereof...... are for the conceptualization and governance of cold disasters. Hence, the paper can also be viewed as a response to Alexander’s (2012a) recent call for new theory in the field of disaster risk reduction. The article is structured in four overall parts. The first part, Cold Context, provides an overview of the specific...... conditions in a cold context, exemplified by the Arctic, and zooms in on Greenland to provide more specific background for the paper. The second part, Disasters in Cold Contexts, discusses “cold disasters” in relation to disaster theory, in order to, elucidate how cold disasters challenge existing...

  11. Cold knife cone biopsy

    Science.gov (United States)

    ... biopsy; Pap smear - cone biopsy; HPV - cone biopsy; Human papilloma virus - cone biopsy; Cervix - cone biopsy; Colposcopy - cone biopsy Images Female reproductive anatomy Cold cone biopsy Cold cone removal References American ...

  12. Nonfreezing Cold-Induced Injuries

    Science.gov (United States)

    2012-01-01

    sensitive population. Alternatively, the rise may be caused by a type I statistical error (poor specifi city of the tests used to diagnose NFCI or...Pernio is believed to be caused by prolonged cold-induced vasoconstriction with subsequent hypoxemia and vessel wall infl ammation. 41,55

  13. Nudging at the checkout counter - A longitudinal study of the effect of a food repositioning nudge on healthy food choice.

    Science.gov (United States)

    Van Gestel, L C; Kroese, F M; De Ridder, D T D

    2017-12-20

    Objective The current study is a longitudinal conceptual replication and aimed to investigate the effect of a food repositioning nudge on healthy food choice in a kiosk. Design During eight weeks, sales data were collected. The former four weeks formed the baseline phase and the latter four weeks formed the nudge phase where healthy food products were repositioned at the checkout counter display, while unhealthy alternatives remained available elsewhere in the store. Main Outcome Measures The main variable of interest was the proportion of healthy food products (selected to be repositioned) sold per day. Also exit interviews were administered to gather individual level data about purchases, and awareness and opinions of the nudge. Results Results showed that the proportion of selected healthy food products in total food sales was higher in all four nudge weeks than in all four baseline weeks. Individual level data showed that more customers had bought a selected healthy food product in the nudge phase and that customers generally approved of the nudge. Conclusion The current study strengthened the empirical evidence base of repositioning healthy food products as an effective and well-accepted nudge.

  14. The DARHT Scattering Wire Spectrometer: Operation and Checkout on ETA II

    Energy Technology Data Exchange (ETDEWEB)

    Fessenden, T J

    2005-03-09

    The DARHT Scattering wire energy spectrometer has been realized and checked out on ETA II. The ETA II beam energy is generally around 5.3 MeV. This value varies from pulse-to-pulse by around 0.5% and from month-to-month by as much as 6%. The energy acceptance of the spectrometer is {+-} 5% and the time response is less than 10 ns. The instrument was calibrated to enable absolute measurements of the ETA II beam energy accurate to {+-}3%. The beam energy in MeV is related to the bending magnetic field B{sub kG} according to E{sub MeV} = 0.511[{radical}(1+347.2B{sub kG}{sup 2}) -1]. The major difficulty encountered was in the development of detectors for the scattered electrons passing through the instrument. Fortunately one detector was fabricated that worked satisfactorily which enabled us to complete the tests on ETA II. The ETA II experiments and initial FXR experiments suggest that spurious X-ray signals will not prove troublesome. No results are yet available in the x-ray environment of DARHT.

  15. Evaluation of endothelium-dependent myocardial perfusion reserve in healthy smokers; cold pressor test using H{sub 2}{sup 15}O PET

    Energy Technology Data Exchange (ETDEWEB)

    Hwang, Kyung Hoon [School of Medicine, Gachon Univ., Incheon (Korea, Republic of); Lee, Dong Soo; Lee, Byeong Il; Lee, Jae Sung; Lee, Ho Young; Chung, June Key; Lee, Myung Chul [College of Medicine, Seoul National Univ., Seoul (Korea, Republic of)

    2004-02-01

    Much evidence suggests long-term cigarette smoking alters coronary vascular endothelial response. In this study, we applied nonnegative matrix factorization (NMF), an unsupervised learning algorithm, to CO-less H{sub 2}{sup 15}O-PET to investigate coronary endothelial dysfunction caused by smoking noninvasively. This study enrolled eighteen young male volunteers consisting of 9 smokers (23.8{+-}1.1 yr; 6.6{+-}2.5 pack-years) and 9 nonsmokers (23.8{+-}2.9 yr). They do not have any cardiovascular risk factor or disease history. Myocardial H{sub 2}{sup 15}O-PET was performed at rest, during cold (5.deg.C) pressor stimulation and during adenosine infusion. Left ventricular blood pool and myocardium were segmented on dynamic PET data by NMF method. Myocardial blood flow (MBF) was calculated from input and tissue functions by a single compartmental model with correction of partial volume and spillover effects. There were no significant difference in resting MBF between the two groups (Smokers: 1.43 0.41ml/g/min and non-smokers: 1.37{+-}0.41 ml/g/min; p = NS). during cold pressor stimulation, MBF in smokers was significantly lower than that in non-smokers (1.25{+-}0.34 ml/g/min vs 1.59{+-}0.29 ml/g/min ; p = 0.019). The difference in the ratio of cold pressor MBF to resting MBF between the two groups was also significant (p=0.024; 90{+-}24% in smokers and 122{+-}28% in non-smokers.). During adenosine infusion, however, hyperemic MBF did not differ significantly between smokers and non-smokers (5.81{+-}1.99 ml/g/min vs 5.11{+-}1.31 ml/g/min ; p=NS). In smokers, MBF during cold pressor stimulation was significantly lower compared with nonsmokers, reflecting smoking-induced endothelial dysfunction. However, there was no significant difference in MBF during adenosine-induced hyperemia between the two groups.

  16. Hardware independence checkout software

    Science.gov (United States)

    Cameron, Barry W.; Helbig, H. R.

    1990-01-01

    ACSI has developed a program utilizing CLIPS to assess compliance with various programming standards. Essentially the program parses C code to extract the names of all function calls. These are asserted as CLIPS facts which also include information about line numbers, source file names, and called functions. Rules have been devised to establish functions called that have not been defined in any of the source parsed. These are compared against lists of standards (represented as facts) using rules that check intersections and/or unions of these. By piping the output into other processes the source is appropriately commented by generating and executing parsed scripts.

  17. Engine Cold Start

    Science.gov (United States)

    2015-09-01

    UNCLASSIFIED UNCLASSIFIED ENGINE COLD START INTERIM REPORT TFLRF No. 469 by Douglas M. Yost Gregory A. T. Hansen U.S...not return it to the originator. UNCLASSIFIED UNCLASSIFIED ENGINE COLD START INTERIM REPORT TFLRF No. 469 by Douglas M. Yost...TITLE AND SUBTITLE Engine Cold Start 5a. CONTRACT NUMBER W56HZV-09-C-0100 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR(S) Douglas

  18. Wood construction under cold climate

    DEFF Research Database (Denmark)

    Wang, Xiaodong; Hagman, Olle; Sundqvist, Bror

    2014-01-01

    As wood constructions increasingly use engineered wood products worldwide, concerns arise about the integrity of the wood and adhesives system. The glueline stability is a crucial issue for engineered wood application, especially under cold climate. In this study, Norway spruce (Picea abies...... specimens need to be tested in further work to more completely present the issue. The EN 301 and EN 302 may need to be specified based on wood species....

  19. Neutron and proton tests of different technologies for the upgrade of the cold readout electronics of the ATLAS Hadronic End-cap Calorimeter

    CERN Document Server

    INSPIRE-00030110

    2013-01-01

    The expected increase of total integrated luminosity by a factor ten at the HL-LHC compared to the design goals for LHC essentially eliminates the safety factor for radiation hardness realized at the current cold amplifiers of the ATLAS Hadronic End-cap Calorimeter (HEC). New more radiation hard technologies have been studied: SiGe bipolar, Si CMOS FET and GaAs FET transistors have been irradiated with neutrons up to an integrated fluence of 2.2 x 10^{16} n/cm^2 and with 200 MeV protons up to an integrated fluence of 2.6 x 10^{14} p/cm^2. Comparisons of transistor parameters such as the gain for both types of irradiations are presented.

  20. Working in the Cold

    Centers for Disease Control (CDC) Podcasts

    2016-02-08

    During the winter, many workers are outdoors, working in cold, wet, icy, or snowy conditions. Learn how to identify symptoms that tell you there may be a problem and protect yourself from cold stress.  Created: 2/8/2016 by National Institute for Occupational Safety and Health (NIOSH).   Date Released: 2/8/2016.

  1. COLD-WORKED HARDWARE

    Directory of Open Access Journals (Sweden)

    N. M. Strizhak

    2007-01-01

    Full Text Available The different types of cold-worked accessory are examined in the article. The necessity of development of such type of accessory in the Republic of Belarus due to requirements of market is shown. High emphasis is placed on the methods of increase of plasticity of cold-worked accessory from usual mill of RUP and CIS countries.

  2. Human whole body cold adaptation.

    NARCIS (Netherlands)

    Daanen, Hein A.M.; Van Marken Lichtenbelt, Wouter D.

    2016-01-01

    Reviews on whole body human cold adaptation generally do not distinguish between population studies and dedicated acclimation studies, leading to confusing results. Population studies show that indigenous black Africans have reduced shivering thermogenesis in the cold and poor cold induced

  3. Innovative Test Operations to Support Orion and Future Human Rated Missions

    Science.gov (United States)

    Koenig, William J.; Garcia, Rafael; Harris, Richard F.; See, Michael J.; Van Lear, Benjamin S.; Dobson, Jill M.; Norris, Scott Douglas

    2017-01-01

    This paper describes how the Orion program is implementing new and innovative test approaches and strategies in an evolving development environment. The early flight test spacecraft are evolving in design maturity and complexity requiring significant changes in the ground test operations for each mission. The testing approach for EM-2 is planned to validate innovative Orion production acceptance testing methods to support human exploration missions in the future. Manufacturing and testing at Kennedy Space Center in the Neil Armstrong Operations and Checkout facility will provide a seamless transition directly to the launch site avoiding transportation and checkout of the spacecraft from other locations.

  4. Stacking of cold antiprotons

    CERN Document Server

    Gabrielse, G; Oxley, P; Speck, A K; Storry, C H; Tan, J N; Wessels, M; Grzonka, D; Oelert, W; Schepers, G; Sefzick, T; Walz, J; Pittner, H; Hänsch, T W; Hessels, E A

    2002-01-01

    The stacking of cold antiprotons is currently the only way to accumulate the large numbers of the cold antiprotons that are needed for low energy experiments. Both the largest possible number and the lowest possible temperature are desired, especially for the production and study of cold antihydrogen. The antiprotons accumulated in our particle trap have an energy 10/sup 10/ times lower than the energy of those delivered by CERN's Antiprotons Decelerator (AD). The number accumulated (more than 0.4 million in this demonstration) is linear in the number of accepted high energy antiproton pulses (32 in this demonstration). Accumulation efficiencies and losses are measured and discussed. (12 refs).

  5. Heating up cold agglutinins

    National Research Council Canada - National Science Library

    Stone, Marvin J

    2010-01-01

    In this issue of Blood, Berentsen and coworkers describe a high response rate which is durable in some patients who receive combination fludarabine and rituximab for chronic cold agglutinin disease (CAD...

  6. Chilling Out With Colds

    Science.gov (United States)

    ... a little earlier for a few nights. De-stress. Kids who are stressed out feel worse when they have colds. Relax and use the time to read, listen to music, or watch a movie. In other words, chill ...

  7. Cold Vacuum Drying Facility

    Data.gov (United States)

    Federal Laboratory Consortium — Located near the K-Basins (see K-Basins link) in Hanford's 100 Area is a facility called the Cold Vacuum Drying Facility (CVDF).Between 2000 and 2004, workers at the...

  8. Cold-induced metabolism

    NARCIS (Netherlands)

    Van Marken Lichtenbelt, Wouter D.; Daanen, Hein A M

    Purpose of review: Cold response can be insulative (drop in peripheral temperature) or metabolic (increase in energy expenditure). Nonshivering thermogenesis by sympathetic, norepinephrine-induced mitochondrial heat production in brown adipose tissue is a well known component of this metabolic

  9. Cold-induced metabolism

    NARCIS (Netherlands)

    Lichtenbelt, W. van Marken; Daanen, H.A.M.

    2003-01-01

    Purpose of review Cold response can be insulative (drop in peripheral temperature) or metabolic (increase in energy expenditure). Nonshivering thermogenesis by sympathetic, norepinephrine-induced mitochondrial heat production in brown adipose tissue is a well known component of this metabolic

  10. Dence Cold Matter

    Directory of Open Access Journals (Sweden)

    Stavinskiy Alexey

    2014-04-01

    Full Text Available Possible way to create dense cold baryonic matter in the laboratory is discussed. The density of this matter is comparable or even larger than the density of neutron star core. The properties of this matter can be controlled by trigger conditions. Experimental program for the study of properties of dense cold matter for light and heavy ion collisions at initial energy range √sNN~2-3GeV is proposed..

  11. Pure Cold-Induced Cholinergic Urticaria in a Pediatric Patient

    Directory of Open Access Journals (Sweden)

    Tina Abraham

    2016-01-01

    Full Text Available Cold urticaria and cholinergic urticaria are two distinct entities. The presentation of exclusive cold-induced cholinergic urticaria is very rare. The patient described herein had experienced urticaria in the exclusive setting of exercising in a cold environment. Urticarial testing including laboratory and in-office testing was all negative. The patient has prevented urticaria symptoms with oral antihistamine therapy. Pure cold-induced cholinergic urticaria is rarely described in literature. This form of urticaria has yet to be described in a pediatric patient.

  12. Cold adaptation, aging, and Korean women divers haenyeo.

    Science.gov (United States)

    Lee, Joo-Young; Park, Joonhee; Kim, Siyeon

    2017-08-08

    We have been studying the thermoregulatory responses of Korean breath-hold women divers, called haenyeo, in terms of aging and cold adaptation. During the 1960s to the 1980s, haenyeos received attention from environmental physiologists due to their unique ability to endure cold water while wearing only a thin cotton bathing suit. However, their overall cold-adaptive traits have disappeared since they began to wear wetsuits and research has waned since the 1980s. For social and economic reasons, the number of haenyeos rapidly decreased to 4005 in 2015 from 14,143 in 1970 and the average age of haenyeos is about 75 years old at present. For the past several years, we revisited and explored older haenyeos in terms of environmental physiology, beginning with questionnaire and field studies and later advancing to thermal tolerance tests in conjunction with cutaneous thermal threshold tests in a climate chamber. As control group counterparts, older non-diving females and young non-diving females were compared with older haenyeos in the controlled experiments. Our findings were that older haenyeos still retain local cold tolerance on the extremities despite their aging. Finger cold tests supported more superior local cold tolerance for older haenyeos than for older non-diving females. However, thermal perception in cold reflected aging effects rather than local cold acclimatization. An interesting finding was the possibility of positive cross-adaptation which might be supported by greater heat tolerance and cutaneous warm perception thresholds of older haenyeos who adapted to cold water. It was known that cold-adaptive traits of haenyeos disappeared, but we confirmed that cold-adaptive traits are still retained on the face and hands which could be interpreted by a mode switch to local adaptation from the overall adaptation to cold. Further studies on cross-adaptation between chronic cold stress and heat tolerance are needed.

  13. Evolution of solid rocket booster component testing

    Science.gov (United States)

    Lessey, Joseph A.

    1989-01-01

    The evolution of one of the new generation of test sets developed for the Solid Rocket Booster of the U.S. Space Transportation System. Requirements leading to factory checkout of the test set are explained, including the evolution from manual to semiautomated toward fully automated status. Individual improvements in the built-in test equipment, self-calibration, and software flexibility are addressed, and the insertion of fault detection to improve reliability is discussed.

  14. Finishing of the cold mass assembly

    CERN Multimedia

    Patrice Loïez

    2001-01-01

    Photo 1 Technicians are putting in order the instrumentation wires. The prototype magnets were equipped with numerous sensors to monitor key parameters during the performance tests at cold conditions. Photo 2 The cold mass assembly is resting on special supports in order to allow the finishing operations. Technicians are putting in order the instrumentation wires. The prototype magnets were equipped with numerous sensors to monitor key parameters during the performance tests at cold conditions. Photo 3 View of the lyre-side end of the active part assembly. The extremity of the shrinking cylinder has been bevelled in view of welding the end cover. Photo 4 General view of the finishing station showing the special supporting structures (blue and yellow structures) needed for the geometric measurements and for the alignment operations. One can also see the light building surrounding the finishing station, which purpose is to isolate the laser measuring machines from disturbances. Photo 5 The extremity of the shri...

  15. Cold regions isotope applications

    Energy Technology Data Exchange (ETDEWEB)

    Perrigo, L.D.; Divine, T.E.

    1976-04-01

    Pacific Northwest Laboratories (PNL) started the Cold Regions Isotope Applications Program in FY-1975 to identify special conditions in the Arctic and similar geographic areas (Cold Regions) where radioisotope power, heater, or sterilization systems would be desirable and economically viable. Significant progress was made in the first year of this program and all objectives for this initial 12-month period were achieved. The major conclusions and recommendations resulting for this effort are described below. The areas of interest covered include: radiosterilization of sewage; heating of septic tanks; and radioisotope thermoelectric generators as power sources for meteorological instruments and navigational aids. (TFD)

  16. Commemoration of a cold war

    DEFF Research Database (Denmark)

    Farbøl, Rosanna

    2015-01-01

    and heritage sites as case studies, this article sheds new light on the politics of history involved in Cold War commemoration. It suggests that the Cold War is commemorated as a war, yet this war memory is of a particular kind: it is a war memory without victims.......This article brings together the fields of Cold War studies and memory studies. In Denmark, a remarkable institutionalisation of Cold War memory has taken place in the midst of a heated ideological battle over the past and whether to remember the Cold War as a ‘war’. Using Danish Cold War museums...

  17. Theoretical and experimental performance analysis for cold trap design

    Energy Technology Data Exchange (ETDEWEB)

    Hemanath, M.G., E-mail: hemanath@igcar.gov.i [Fast Reactor Technology Group, Indira Gandhi Center for Atomic Research, Kalpakkam (India); Meikandamurthy, C.; Kumar, A. Ashok; Chandramouli, S.; Rajan, K.K.; Rajan, M.; Vaidyanathan, G.; Padmakumar, G.; Kalyanasundaram, P.; Raj, Baldev [Fast Reactor Technology Group, Indira Gandhi Center for Atomic Research, Kalpakkam (India)

    2010-10-15

    Cold trap is a purification unit used in sodium system of FBR's for maintaining the oxygen/hydrogen level in sodium within acceptable limits. It works on the principle of crystallization and precipitation of oxides/hydrides of sodium in a wire mesh, when the temperature of sodium is reduced below the saturation temperature. The cold traps presently used have lower effectiveness and get plugged prematurely. The plugged cold traps are cleaned and then put back into service. Frequent cleaning of cold trap results in the long down time of the sodium system. New design of cold trap has been conceived to overcome the above problems. The mathematical modeling for the new design was carried out and validated with experimentally tested results for its effectiveness. This paper shares the experience gained on the new design of cold trap for FBR's.

  18. Gas production from a cold, stratigraphically-bounded gas hydrate deposit at the Mount Elbert Gas Hydrate Stratigraphic Test Well, Alaska North Slope: Implications of uncertainties

    Science.gov (United States)

    Moridis, G.J.; Silpngarmlert, S.; Reagan, M.T.; Collett, T.; Zhang, K.

    2011-01-01

    As part of an effort to identify suitable targets for a planned long-term field test, we investigate by means of numerical simulation the gas production potential from unit D, a stratigraphically bounded (Class 3) permafrost-associated hydrate occurrence penetrated in the BPXA-DOE-USGS Mount Elbert Gas Hydrate Stratigraphic Test Well on North Slope, Alaska. This shallow, low-pressure deposit has high porosities (?? = 0.4), high intrinsic permeabilities (k = 10-12 m2) and high hydrate saturations (SH = 0.65). It has a low temperature (T = 2.3-2.6 ??C) because of its proximity to the overlying permafrost. The simulation results indicate that vertical wells operating at a constant bottomhole pressure would produce at very low rates for a very long period. Horizontal wells increase gas production by almost two orders of magnitude, but production remains low. Sensitivity analysis indicates that the initial deposit temperature is by the far the most important factor determining production performance (and the most effective criterion for target selection) because it controls the sensible heat available to fuel dissociation. Thus, a 1 ??C increase in temperature is sufficient to increase the production rate by a factor of almost 8. Production also increases with a decreasing hydrate saturation (because of a larger effective permeability for a given k), and is favored (to a lesser extent) by anisotropy. ?? 2010.

  19. Testing of a hot- and cold-wire probe to measure simultaneously the speed and temperature in supercritical CO{sub 2} flow

    Energy Technology Data Exchange (ETDEWEB)

    Vukoslavcevic, Petar V.; Radulovic, Ivana M. [University of Montenegro, Podgorica (Czechoslovakia); Wallace, James M. [University of Maryland, MD (United States)

    2005-10-01

    The use of hot-wire anemometry in carbon dioxide flow under supercritical conditions has been analyzed and implemented for the first time. A two-sensor probe to simultaneously measure streamwise velocity and temperature in this flow has been designed and constructed. A calibration and test flow loop that can provide supercritical state conditions above the critical point has been also designed, fabricated and tested. The temperature and velocity flow fields of the flow loop can be varied at constant pressure. It has been found that, above the pseudo-critical temperature, the velocity sensor response fits King's cooling law with a high correlation coefficient. The dependence of the King's law parameters on temperature can be accurately presented with second or higher order polynomial or exponential fits, depending on the extent of the temperature range. Below the pseudocritical temperature the data is scattered, and the variation with temperature of the King's law parameters, determined from calibration, is irregular. The influence on this data scatter of the strong variation of the fluid properties near the critical point is analyzed, and a possibility to reduce it is proposed. The temperature sensor response both above and below the pseudocritical temperature is similar to the response under normal conditions. It is linear with a very high correlation coefficient between the calibration data and the fitted curve. It is also shown that the temperature response is not affected by variation of the flow's speed. (orig.)

  20. Heating up cold agglutinins.

    Science.gov (United States)

    Stone, Marvin J

    2010-10-28

    In this issue of Blood, Berentsen and coworkers describe a high response rate which is durable in some patients who receive combination fludarabine and rituximab for chronic cold agglutinin disease (CAD). If confirmed, this is a significant advance in therapy for a frequently difficult clinical problem.

  1. Recent Cold War Studies

    Science.gov (United States)

    Pineo, Ronn

    2003-01-01

    Cold War historiography has undergone major changes since the 1991 collapse of the Soviet Union. For two years (1992-1993) the principal Soviet archives fell open to scholars, and although some of the richest holdings are now once again closed, new information continues to find its way out. Moreover, critical documentary information has become…

  2. Cold spray nozzle design

    Science.gov (United States)

    Haynes, Jeffrey D [Stuart, FL; Sanders, Stuart A [Palm Beach Gardens, FL

    2009-06-09

    A nozzle for use in a cold spray technique is described. The nozzle has a passageway for spraying a powder material, the passageway having a converging section and a diverging section, and at least the diverging section being formed from polybenzimidazole. In one embodiment of the nozzle, the converging section is also formed from polybenzimidazole.

  3. Teaching "In Cold Blood."

    Science.gov (United States)

    Berbrich, Joan D.

    1967-01-01

    The Truman Capote nonfiction novel, "In Cold Blood," which reflects for adolescents the immediacy of the real world, illuminates (1) social issues--capital punishment, environmental influence, and the gap between the "haves" and "have-nots," (2) moral issues--the complexity of man's nature, the responsibility of one…

  4. All-Micromachined Joule-Thomson Cold Stage

    NARCIS (Netherlands)

    Lerou, P.P.M.; Venhorst, G.C.F.; Venhorst, G.C.F.; Veenstra, T.T.; Jansen, Henricus V.; Burger, Johannes Faas; Holland, Herman J.; ter Brake, Hermanus J.M.; Rogalla, Horst; Miller, S.D.; Ross jr., R.G.

    2007-01-01

    A micro Joule-Thomson cold stage was designed, built and tested, as part of the micro cooling research project at the University of Twente. The cold stage consists of a stack of three glass wafers. In the top wafer, the high-pressure line is etched as a rectangular channel with supporting pillars.

  5. Characterization of Medicago populations under cold acclimation by ...

    African Journals Online (AJOL)

    Characterization of Medicago populations under cold acclimation by morphological traits and microsatellite (SSR) markers. ... altitude (lower ability to cold acclimation). Tests differentiation between species by fisher pair indicates that all species were different from each other. Results show the highest level of homozygosity ...

  6. Effects of photoperiodically induced reproductive diapause and cold hardening on the cold tolerance of Drosophila montana.

    Science.gov (United States)

    Vesala, Laura; Hoikkala, Anneli

    2011-01-01

    Coping with seasonal and daily variation in environmental conditions requires that organisms are able to adjust their reproduction and stress tolerance according to environmental conditions. Females of Drosophila montana populations have adapted to survive over the dark and cold winters at high latitudes and altitudes by spending this season in photoperiodically controlled reproductive diapause and reproducing only in spring/summer. The present study showed that flies of a northern population of this species are quite tolerant of low temperatures and show high seasonal and short-term plasticity in this trait. Culturing the flies in short day length (nearly all females in reproductive diapause), as well as allowing the flies to get cold hardened before the cold treatment, increased the cold tolerance of both sexes both in chill coma recovery time test and in mortality assay. Chill coma recovery time test performed for the females of two additional D. montana populations cultured in a day length where about half of the females enter diapause, also showed that diapause can increase female cold tolerance even without a change in day length. Direct linkage between diapause and cold tolerance was found in only two strains representing a high-altitude population of the species, but the phenomenon will certainly be worth of studying in northern and southern populations of the species with larger data sets. 2010 Elsevier Ltd. All rights reserved.

  7. Cutaneous microvascular response during local cold exposure - the effect of female sex hormones and cold perception.

    Science.gov (United States)

    Cankar, Ksenija; Music, Mark; Finderle, Zare

    2016-11-01

    It is generally known that differences exist between males and females with regard to sensitivity to cold. Similar differences even among females in different hormonal balance might influence microvascular response during cold provocation testing. The aim of the present study was to measure sex hormone levels, cold and cold pain perception thresholds and compare them to cutaneous laser-Doppler flux response during local cooling in both the follicular and luteal phases of the menstrual cycle. In the luteal phase a more pronounced decrease in laser-Doppler flux was observed compared to follicular phase during local cooling at 15°C (significant difference by Dunnett's test, p<0.05). In addition, statistically significant correlations between progesterone level and laser-Doppler flux response to local cooling were observed during the follicular (R=-0.552, p=0.0174) and during the luteal phases (R=0.520, p=0.0271). In contrast, the correlation between estradiol level and laser-Doppler flux response was observed only in the follicular phase (R=-0.506, p=0.0324). Our results show that individual sensitivity to cold influences cutaneous microvascular response to local cooling; that microvascular reactivity is more pronounced during the luteal phase of the menstrual cycle; and that reactivity correlates with hormone levels. The effect of specific sex hormone levels is related to the cold-provocation temperature. Copyright © 2016. Published by Elsevier Inc.

  8. Herpes Simplex Virus (Cold Sores)

    Science.gov (United States)

    ... Print Share Cold Sores in Children: About the Herpes Simplex Virus Page Content ​A child's toddler and ... Cold sores (also called fever blisters or oral herpes) start as small blisters that form around the ...

  9. Status of the irradiation test vehicle for testing fusion materials in the Advanced Test Reactor

    Energy Technology Data Exchange (ETDEWEB)

    Tsai, H.; Gomes, I.C.; Smith, D.L. [Argonne National Lab., IL (United States); Palmer, A.J.; Ingram, F.W. [Lockheed Martin Idaho Technologies Co., Idaho Falls, ID (United States); Wiffen, F.W. [Dept. of Energy, Germantown, MD (United States). Office of Fusion Energy

    1998-09-01

    The design of the irradiation test vehicle (ITV) for the Advanced Test Reactor (ATR) has been completed. The main application for the ITV is irradiation testing of candidate fusion structural materials, including vanadium-base alloys, silicon carbide composites, and low-activation steels. Construction of the vehicle is underway at the Lockheed Martin Idaho Technology Company (LMITCO). Dummy test trains are being built for system checkout and fine-tuning. Reactor insertion of the ITV with the dummy test trains is scheduled for fall 1998. Barring unexpected difficulties, the ITV will be available for experiments in early 1999.

  10. Trainability of cold induced vasodilation

    NARCIS (Netherlands)

    Daanen, H.A.M.; Raymann, R.J.E.M.; Stoop, M.

    2007-01-01

    Peripheral cold injuries are often reported in mountaineers. Not only low ambient temperatures, but also the hypobaric circumstances are known to be major environmental risk factors. When the fingers are exposed to extreme cold for several minutes, cold induced vasodilation (CIVD) occurs, that is

  11. The need to be cold : cold warriors

    Energy Technology Data Exchange (ETDEWEB)

    Gregoire, L.

    2008-10-15

    This article discussed the changing climate of Ellesmere Island and the adaptation of the Inuit in response to the climate change, with particular reference to Canada's most northern community of Grise Fiord. Because of the changing climate, the vast northern landscape that the Inuit navigated for centuries by reading its subtle signs is becoming warmer, softer, and unpredictable. The geographic history and demographics of Grise Fiord were described. The community's main water supply comes from a glacier which is sinking. The negative impacts of ice shrinkage on this northern community and on the environment were presented. These included more international shipping through the Arctic, more resource exploration, a greater risk of environmental contamination, and reduced habitat for the polar bears and seals that eat, mate, and reproduce on the ice. Climate change impacts on the sea and sea ice were also discussed. Several photographs illustrating the changing climate were presented. The article noted that climate change could destroy the Inuit culture, making climate change an issue of human rights, notably the right to live connected to the land and the right to be cold. It was concluded that in one generation, Inuit were swept up by both a social and an economic upheaval. In one more generation, they will undergo an environmental shift. 13 figs.

  12. Viscoelastic behaviour of cold recycled asphalt mixes

    Science.gov (United States)

    Cizkova, Zuzana; Suda, Jan

    2017-09-01

    Behaviour of cold recycled mixes depends strongly on both the bituminous binder content (bituminous emulsion or foamed bitumen) and the hydraulic binder content (usually cement). In the case of cold recycled mixes rich in bitumen and with low hydraulic binder content, behaviour is close to the viscoelastic behaviour of traditional hot mix asphalt. With decreasing bituminous binder content together with increasing hydraulic binder content, mixes are characteristic with brittle behaviour, typical for concrete pavements or hydraulically bound layers. The behaviour of cold recycled mixes with low content of both types of binders is similar to behaviour of unbound materials. This paper is dedicated to analysing of the viscoelastic behaviour of the cold recycled mixes. Therefore, the tested mixes contained higher amount of the bituminous binder (both foamed bitumen and bituminous emulsion). The best way to characterize any viscoelastic material in a wide range of temperatures and frequencies is through the master curves. This paper includes interesting findings concerning the dependency of both parts of the complex modulus (elastic and viscous) on the testing frequency (which simulates the speed of heavy traffic passing) and on the testing temperature (which simulates the changing climate conditions a real pavement is subjected to).

  13. WISPy cold dark matter

    Energy Technology Data Exchange (ETDEWEB)

    Arias, Paola [Deutsches Elektronen-Synchrotron (DESY), Hamburg (Germany); Pontificia Univ. Catolica de Chile, Santiago (Chile). Facultad de Fisica; Cadamuro, Davide; Redondo, Javier [Max-Planck-Institut fuer Physik, Muenchen (Germany); Goodsell, Mark [Deutsches Elektronen-Synchrotron (DESY), Hamburg (Germany); European Organization for Nuclear Research (CERN), Geneva (Switzerland); Jaeckel, Joerg [Durham Univ. (United Kingdom). Inst. for Particle Physics Phenomenology; Ringwald, Andreas [Deutsches Elektronen-Synchrotron (DESY), Hamburg (Germany)

    2012-01-15

    Very weakly interacting slim particles (WISPs), such as axion-like particles (ALPs) or hidden photons (HPs), may be non-thermally produced via the misalignment mechanism in the early universe and survive as a cold dark matter population until today. We find that, both for ALPs and HPs whose dominant interactions with the standard model arise from couplings to photons, a huge region in the parameter spaces spanned by photon coupling and ALP or HP mass can give rise to the observed cold dark matter. Remarkably, a large region of this parameter space coincides with that predicted in well motivated models of fundamental physics. A wide range of experimental searches - exploiting haloscopes (direct dark matter searches exploiting microwave cavities), helioscopes (searches for solar ALPs or HPs), or light-shining-through-a-wall techniques - can probe large parts of this parameter space in the foreseeable future. (orig.)

  14. Progress with cold antihydrogen

    CERN Document Server

    Charlton, M; Amsler, C; Bonomi, G; Bowe, P D; Canali, C; Carraro, C; Cesar, C L; Doser, M; Fontana, A; Fujiwara, M C; Funakoshi, R; Genova, P; Hangst, J S; Hayano, R S; Johnson, I; Jørgensen, L V; Kellerbauer, A G; Lagomarsino, V; Landua, Rolf; Lodi-Rizzini, E; Macri, M; Madsen, N; Manuzio, G; Mitchard, D; Montagna, P; Pruys, H; Regenfus, C; Rotondi, A; Testera, G; Variola, A; Venturelli, L; Van der Werf, D P; Yamazaki, Y; Zurlo, N

    2006-01-01

    The creation of cold antihydrogen by the ATHENA and ATRAP collaborations, working at CERN's unique Antiproton Decelerator (AD) facility, has ushered in a new era in atomic physics. This contribution will briefly review recent results from the ATHENA experiment. These include discussions of antiproton slowing down in a cold positron gas during antihydrogen formation, information derived on the dependence of the antihydrogen formation rate upon the temperature of the stored positron plasma and, finally, upon the spatial distribution of the emitted anti-atoms. We will discuss the implications of these studies for the major outstanding goal of trapping samples of antihydrogen for precise spectroscopic comparisons with hydrogen. The physics motivations for undertaking these challenging experiments will be briefly recalled.

  15. WISPy Cold Dark Matter

    CERN Document Server

    Arias, Paola; Goodsell, Mark; Jaeckel, Joerg; Redondo, Javier; Ringwald, Andreas

    2012-01-01

    Very weakly interacting slim particles (WISPs), such as axion-like particles (ALPs) or hidden photons (HPs), may be non-thermally produced via the misalignment mechanism in the early universe and survive as a cold dark matter population until today. We find that, both for ALPs and HPs whose dominant interactions with the standard model arise from couplings to photons, a huge region in the parameter spaces spanned by photon coupling and ALP or HP mass can give rise to the observed cold dark matter. Remarkably, a large region of this parameter space coincides with that predicted in well motivated models of fundamental physics. A wide range of experimental searches -- exploiting haloscopes (direct dark matter searches exploiting microwave cavities), helioscopes (searches for solar ALPs or HPs), or light-shining-through-a-wall techniques -- can probe large parts of this parameter space in the foreseeable future.

  16. Dense cold matter

    Directory of Open Access Journals (Sweden)

    Stavinskiy Alexey

    2016-01-01

    Full Text Available The possibility to study cold nuclear matter with the density of neutron star core and even larger in the laboratory experiment is discussed. Special rare kinematical trigger for relativistic ion-ion collisions is proposed for such study. Expected properties of the matter in such unusual conditions and experimental program for its study is discussed. Possible experimental setup and R&D results for position sensitive neutron detector are presented.

  17. The CMS COLD BOX

    CERN Multimedia

    Brice, Maximilien

    2015-01-01

    The CMS detector is built around a large solenoid magnet. This takes the form of a cylindrical coil of superconducting cable that generates a field of 3.8 Tesla: about 100,000 times the magnetic field of the Earth. To run, this superconducting magnet needs to be cooled down to very low temperature with liquid helium. Providing this is the job of a compressor station and the so-called “cold box”.

  18. Clumpy cold dark matter

    Science.gov (United States)

    Silk, Joseph; Stebbins, Albert

    1993-01-01

    A study is conducted of cold dark matter (CDM) models in which clumpiness will inhere, using cosmic strings and textures suited to galaxy formation. CDM clumps of 10 million solar mass/cu pc density are generated at about z(eq) redshift, with a sizable fraction surviving. Observable implications encompass dark matter cores in globular clusters and in galactic nuclei. Results from terrestrial dark matter detection experiments may be affected by clumpiness in the Galactic halo.

  19. Clinical Cold Welding of the Modular Total Hip Arthroplasty Prosthesis.

    Science.gov (United States)

    Whittaker, Robert K; Zaghloul, Ahmed M; Hothi, Harry S; Siddiqui, Imran A; Blunn, Gordon W; Skinner, John A; Hart, Alister J

    2017-02-01

    A head that is "clinically cold welded" to a stem is one of the commonest reasons for unplanned removal of the stem. It is not clear which hip designs are at greatest risk of clinical cold welding. This was a case-control study of consecutively received hip implant retrievals; we chose the design of hip that had the greatest number of truly cold-welded heads (n = 11). For our controls, we chose retrieved hips of the same design but without cold welding of the head (n = 35). We compared the clinical variables between these 2 groups using nonparametric Mann-Whitney tests to investigate the significance of differences between the cold-welded and non-cold-welded groups. The design that most commonly caused cold welding was a combination of a Ti stem and Ti taper: 11 out of 48 (23%) were truly cold welded. Comparison of the clinical data showed that no individual factor could be used to predict this preoperatively with none of the 4 predictors tested showing any significance: (1) time to revision (P = .687), (2) head size (P = .067), (3) patient age at primary (P = .380), and (4) gender (P = .054). We have shown that clinical cold welding is most prevalent in Ti-Ti combinations of the stem and taper; approximately 25% of cases received at our center were cold welded. Analysis of clinical variables showed that it is not possible to predict which will be cold welded preoperatively. Surgeons should be aware of this potential complication when revising a Ti-Ti stem/head junction. Copyright © 2016 Elsevier Inc. All rights reserved.

  20. KCNQ channels in nociceptive cold-sensing trigeminal ganglion neurons as therapeutic targets for treating orofacial cold hyperalgesia.

    Science.gov (United States)

    Abd-Elsayed, Alaa A; Ikeda, Ryo; Jia, Zhanfeng; Ling, Jennifer; Zuo, Xiaozhuo; Li, Min; Gu, Jianguo G

    2015-07-31

    Hyperexcitability of nociceptive afferent fibers is an underlying mechanism of neuropathic pain and ion channels involved in neuronal excitability are potentially therapeutic targets. KCNQ channels, a subfamily of voltage-gated K(+) channels mediating M-currents, play a key role in neuronal excitability. It is unknown whether KCNQ channels are involved in the excitability of nociceptive cold-sensing trigeminal afferent fibers and if so, whether they are therapeutic targets for orofacial cold hyperalgesia, an intractable trigeminal neuropathic pain. Patch-clamp recording technique was used to study M-currents and neuronal excitability of cold-sensing trigeminal ganglion neurons. Orofacial operant behavioral assessment was performed in animals with trigeminal neuropathic pain induced by oxaliplatin or by infraorbital nerve chronic constrictive injury. We showed that KCNQ channels were expressed on and mediated M-currents in rat nociceptive cold-sensing trigeminal ganglion (TG) neurons. The channels were involved in setting both resting membrane potentials and rheobase for firing action potentials in these cold-sensing TG neurons. Inhibition of KCNQ channels by linopirdine significantly decreased resting membrane potentials and the rheobase of these TG neurons. Linopirdine directly induced orofacial cold hyperalgesia when the KCNQ inhibitor was subcutaneously injected into rat orofacial regions. On the other hand, retigabine, a KCNQ channel potentiator, suppressed the excitability of nociceptive cold-sensing TG neurons. We further determined whether KCNQ channel could be a therapeutic target for orofacial cold hyperalgesia. Orofacial cold hyperalgesia was induced in rats either by the administration of oxaliplatin or by infraorbital nerve chronic constrictive injury. Using the orofacial operant test, we showed that retigabine dose-dependently alleviated orofacial cold hyperalgesia in both animal models. Taken together, these findings indicate that KCNQ channel plays a

  1. Complete remission of severe idiopathic cold urticaria on interleukin-1 receptor antagonist (anakinra).

    NARCIS (Netherlands)

    Bodar, E.J.; Simon, A.; Visser, M. de; Meer, J.W.M. van der

    2009-01-01

    A 62-year-old patient had suffered from severe cold intolerance with an urticarial rash and oropharyngeal angio-oedema upon cold exposure since early childhood. This could be provoked by the ice cube test and by exposure in a cold room. Her family history was negative, and she did not carry any

  2. Complete remission of severe idiopathic cold urticaria on interleukin-1 receptor antagonist (anakinra)

    NARCIS (Netherlands)

    Bodar, E. J.; Simon, A.; de Visser, M.; van der Meer, J. W. M.

    2009-01-01

    A 62-year-old patient had suffered from severe cold intolerance with an urticarial rash and oropharyngeal angio-oedema upon cold exposure since early childhood. This could be provoked by the ice cube test and by exposure in a cold room. Her family history was negative, and she did not carry any

  3. Pertussis Tests

    Science.gov (United States)

    ... Factor Antibody Iron Iron Tests JAK2 Mutation Kidney Stone Analysis Kidney Stone Risk Panel KRAS Mutation Lactate Lactate Dehydrogenase (LD) ... whooping cough); when you have symptoms of a cold and have been exposed to someone with pertussis ...

  4. TORCH Test

    Science.gov (United States)

    ... Factor Antibody Iron Iron Tests JAK2 Mutation Kidney Stone Analysis Kidney Stone Risk Panel KRAS Mutation Lactate Lactate Dehydrogenase (LD) ... The two most common infections with HSV are "cold sores" affecting the lips and genital herpes. Both ...

  5. Emotional style and susceptibility to the common cold

    National Research Council Canada - National Science Library

    Cohen, Sheldon; Doyle, William J; Turner, Ronald B; Alper, Cuneyt M; Skoner, David P

    2003-01-01

    .... We tested these hypotheses for host resistance to the common cold. Three hundred thirty-four healthy volunteers aged 18 to 54 years were assessed for their tendency to experience positive emotions such as happy, pleased, and relaxed...

  6. Cold Vacuum Drying (CVD) Facility, Diesel Generator Fire Protection

    CERN Document Server

    Singh, G

    2000-01-01

    This Acceptance Test Procedure (ATP) has been prepared to demonstrate that the Fire Protection and Detection System installed by Project W-441 (Cold Vacuum Drying Facility and Diesel Generator Building) functions as required by project specifications.

  7. Cold agglutinins in patients undergoing cardiac surgery requiring cardiopulmonary bypass.

    Science.gov (United States)

    Barbara, David W; Mauermann, William J; Neal, James R; Abel, Martin D; Schaff, Hartzell V; Winters, Jeffrey L

    2013-09-01

    Cold agglutinins (CA) are circulating autoantibodies present in most humans. They are active below normal body temperatures. Cold hemagglutinin disease involves the presence of CA sufficiently active at temperatures in the periphery to produce hemolysis or agglutination. Systemic hypothermia and cold cardioplegia may result in agglutination or hemolysis. We reviewed the experience of a large referral center in managing patients with CA and cold hemagglutinin disease undergoing cardiac surgery requiring cardiopulmonary bypass. The electronic medical records from 2002 to 2010 were searched to identify patients with CA or cold hemagglutinin disease who underwent cardiac surgery requiring cardiopulmonary bypass. Information related to preoperative CA testing and treatment, surgery, cardiopulmonary bypass, postoperative complications, and mortality was recorded. Sixteen patients underwent 19 procedures requiring cardiopulmonary bypass. Six patients had cold hemagglutinin disease. The identification of CA was made intraoperatively in 3 patients. One patient underwent preoperative plasma exchange. Cold blood cardioplegia was used in 2 of 16 procedures using cardioplegia, with the remaining using warmer blood cardioplegia. The lowest recorded intraoperative core temperature was less than 34 °C in 1 case. CA-related postoperative hemolysis requiring transfusion was present in 1 patient, which was resolved with active warming. No patient had evidence of permanent myocardial dysfunction, had a neurologic event, required dialysis, or died within 30 days. All patients with CA/cold hemagglutinin disease at the Mayo Clinic College of Medicine safely underwent cardiac surgery without major adverse morbidity or mortality. Patients with CA but without evidence of cold hemagglutinin disease can safely undergo normothermic cardiopulmonary bypass at 37°C and warm cardioplegia without further testing. Patients with cold hemagglutinin disease should undergo laboratory testing including

  8. Antivirals for the common cold.

    Science.gov (United States)

    Jefferson, T O; Tyrrell, D

    2001-01-01

    The common cold is a ubiquitous short and usually mild illness for which preventive and treatment interventions have been under development since the mid-40s. As our understanding of the disease has increased, more experimental antivirals have been developed. This review attempts to draw together experimental evidence of the effects of these compounds. To identify, assemble, evaluate and (if possible) synthesise the results of published and unpublished randomised controlled trials of the effects of antivirals to prevent or minimise the impact of the common cold. We searched electronic databases, corresponded with researchers and handsearched the archives of the MRC's Common Cold Unit (CCU). We included original reports of randomised and quasi-randomised trials assessing the effects of antivirals on volunteers artificially infected and in individuals exposed to colds in the community. We included 241 studies assessing the effects of Interferons, interferon-inducers and other antivirals on experimental and naturally occurring common colds, contained in 230 reports. We structured our comparisons by experimental or community setting. Although intranasal interferons have high preventive efficacy against experimental colds (protective efficacy 46%, 37% to 54%) and to a lesser extent against natural colds (protective efficacy 24%, 21% to 27%) and are also significantly more effective than placebo in attenuating the course of experimental colds (WMD 15.90, 13.42 to 18.38), their safety profile makes compliance with their use difficult. For example, prolonged prevention of community colds with interferons causes blood-tinged nasal discharge (OR 4.52, 3.78 to 5.41). Dipyridamole (protective efficacy against natural colds 49%, 30% to 62%), ICI 130, 685 (protective efficacy against experimental colds 58%, 35% to 74% ), Impulsin (palmitate) (protective efficacy against natural colds 44%, CI 35% to 52% ) and Pleconaril (protective efficacy against experimental colds 71%, 15% to

  9. Analysis of Fatigue Crack Paths in Cold Drawn Pearlitic Steel

    Directory of Open Access Journals (Sweden)

    Jesús Toribio

    2015-11-01

    Full Text Available In this paper, a fracto-metallographic analysis was performed on the cracked specimens of cold drawn pearlitic steel subjected to fatigue tests. Fatigue cracks are transcollonial and exhibit a preference for fracturing pearlitic lamellae, with non-uniform crack opening displacement values, micro-discontinuities, branchings, bifurcations and frequent local deflections that create microstructural roughness. At the micro-level, the cold drawn pearlitic steel exhibits higher micro-roughness than the hot rolled bar (this is a consequence of the manufacturing process by cold drawing, so that the actual fractured surface in the cold drawn wire is greater than that in the hot rolled bar, due to the fact that the crack deflection events are more frequent and with higher angle in the former (the heavily drawn prestressing steel wire. These findings show the relevant role on the manufacturing process by cold drawing in the fatigue crack propagation in pearlitic steel.

  10. An empirical model for friction in cold forging

    DEFF Research Database (Denmark)

    Bay, Niels; Eriksen, Morten; Tan, Xincai

    2002-01-01

    With a system of simulative tribology tests for cold forging the friction stress for aluminum, steel and stainless steel provided with typical lubricants for cold forging has been determined for varying normal pressure, surface expansion, sliding length and tool/work piece interface temperature....... The results show, that friction is strongly influenced by normal pressure and tool/work piece interface temperature, whereas the other process parameters investigated show minor influence on friction. Based on the experimental results a mathematical model has been established for friction as a function...... of normal pressure and tool/work piece interface temperature. The model is verified by process testing measuring friction at varying reductions in cold forward rod extrusion. KEY WORDS: empirical friction model, cold forging, simulative friction tests....

  11. Chinese medicinal herbs for the common cold.

    Science.gov (United States)

    Wu, T; Zhang, J; Qiu, Y; Xie, L; Liu, G J

    2007-01-24

    Chinese herbal medicines are frequently used to treat the common cold in China. Until now, their efficacy has not been systematically reviewed. To assess the effectiveness and safety of Chinese herbal medicines for the common cold. We searched the Cochrane Central Register of Controlled Trials (CENTRAL) (The Cochrane Library, Issue 3, 2006) which contains the Acute Respiratory Infections Group's specialised register; MEDLINE (1966 to July 2006); EMBASE (1980 to March 2006); AMED (1985 to July 2006); and the Chinese Biomedical Database (CBM) (1975 to July 2005). Randomised controlled trials (RCTs) studying the efficacy of Chinese herbal medicine(s) for the treatment of the common cold were included, irrespective of publication status or language. Four review authors telephoned original trial authors of the RCTs identified by our searches to verify the randomisation procedure. Two review authors extracted and analysed data from the trials which met the inclusion criteria. Fourteen studies involving 2440 patients were included. The methods of all studies were rated of poor quality (category C). Included studies used "effective drugs" as controls; however, the efficacy of these control drugs was not reported. Different Chinese herbal preparations were tested in nearly all trials; in only one was a Chinese herbal preparation tested twice. In six studies, five herbal preparations were found to be more effective at enhancing recovery than the control; and in the other eight studies, five herbal preparations were shown to be equal to the control. There was a strong probability of different biases in all of the included studies. Chinese herbal medicines may shorten the symptomatic phase in patients with the common cold. However, the lack of high quality clinical trials means we are unable to recommend any kind of Chinese herbal preparation for the common cold.

  12. Natural cold pressed oils as cosmetic products

    Directory of Open Access Journals (Sweden)

    Małgorzata Ligęza

    2016-12-01

    Full Text Available Background. It seems that patients may ask general practitioners about natural cosmetics applied on the skin regarding their safety and suitability. Objectives. The aim of the study was to analyze natural cold pressed oils as potential cosmetic products. Material and methods. Cold pressed oils obtained from selected seeds and fruit stones were analyzed, including: chokeberry seed oil, blackcurrant seed oil, elderberry seed oil, raspberry seed oil, apricot seed oil, tomato seed oil, strawberry seed oil, broccoli seed oil, Nigella sativa seed oil, hemp oil, safflower seed oil, Silybum marianum seed oil and coconut oil. 80 adult volunteers assessed the cosmetic properties of the analyzed oils. Each of the volunteers tested 2 to 4 different oils, by applying them on the skin. In addition, patch tests with all analyzed oils were performed on 23 individuals. Results. The majority of tested oils were positively evaluated by the participants: in the opinion of the participants, oil extracted from safflower had the best appearance (100% positive opinions, coconut oil had the best smell (70% positive opinions, while black currant seed oil showed the best absorbency (85% positive opinions. No irritation was observed within the analyzed product group, albeit one allergic reaction to apricot seed oil was observed with patch testing. Conclusions . Based on the achieved results, it could be suggested that natural cold pressed oils can be applied to the skin as cosmetics. Our observations may be helpful for general practitioners when choosing natural cosmetics.

  13. Homeostatic Responses to Prolonged Cold Exposure: Human Cold Acclimatization

    Science.gov (United States)

    1994-05-01

    they were exposed to cold. The study of the Alacalufs of Tierra del Fuego (22) has been cited as evidence for a metabolic form of cold acclimatization...Bethesda, MD 20889-5044 55 AI Commanding Officer U.S. Navy Clothing & Textile Research Facility P.O. Box 59 Natick, MA 01760-0001 Commanding Officer

  14. Whole-body cold tolerance in older Korean female divers "haenyeo" during cold air exposure: effects of repetitive cold exposure and aging

    Science.gov (United States)

    Park, Joonhee; Kim, Siyeon; Kim, Do-Hee; Cha, Seongwon; Lee, Joo-Young

    2017-11-01

    This study was conducted to investigate the effects of chronic and repetitive diving in cold sea water on physiological responses to cold in older Korean female divers, Haenyeo, who have been exposed to cold water through breath-hold diving since their teens. Young and older females, who have no experience of swimming in cold sea water, were recruited as control groups: older haenyeos (N = 10, 70 ± 3 years of age), young non-diving females (N = 10, 23 ± 2 years), and older non-diving females (N = 6, 73 ± 4 years). For the test of cold exposure, all subjects were exposed to cold in an air temperature of 12 °C with 45% RH in a sitting position for 60 min. The changes in core temperature showed no significant differences between older haenyeos and the other two groups. The decreases in mean skin temperature were greater for older haenyeos than the other two groups (P < 0.01). Older haenyeos had significantly lower energy expenditure during cold exposure when compared to older non-diving females (P < 0.05). Heart rate was significantly lower in older haenyeos than that of young non-diving females (P < 0.05). Older haenyeos felt cooler at the face with lower face temperature when compared with older non-diving females. The results indicate that older haenyeos respond to cold through reducing heat loss from the skin rather than increasing metabolic rate. These responses are distinctive features from the cold defensive system of young or older non-diving females.

  15. Cold gelation of globular proteins

    NARCIS (Netherlands)

    Alting, A.C.

    2003-01-01

    Keywords : globular proteins, whey protein, ovalbumin, cold gelation, disulfide bonds, texture, gel hardnessProtein gelation in food products is important to obtain desirable sensory and textural properties. Cold gelation is a novel method to produce protein-based gels. It is a two step process in

  16. Cold acclimation in eucalypt hybrids.

    Science.gov (United States)

    Almeida, M. H.; Chaves, M. M.; Silva, J. C.

    1994-01-01

    We evaluated cold resistance and the capacity for cold acclimation of different Eucalyptus genotypes. Seedlings of half-sib families of E. globulus and hybrids E. gunnii x globulus, E. viminalis x globulus and E. cypellocarpa x globulus were exposed daily for 56 days to a 9-h photoperiod at 14.7 degrees C, followed by 15 h in a dark cold room maintained at 2.5 degrees C with the root system maintained at 8 degrees C to cold harden the seedlings. Unhardened seedlings were maintained at about 16 degrees C during the dark period. Cold acclimation occurred in all families with decreases in the temperature causing 50% mortality (LT(50)) of between 1.5 and 3 degrees C. Both hardened and unhardened plants of hybrid families were more cold tolerant than E. globulus. A significant correlation between LT(50) and leaf osmotic pressure was observed; the increase in osmotic pressure in hardened plants was predominantly a result of an increase in the concentration of soluble sugars. Exotherm peaks were similar in hardened and unhardened plants. These results indicate that cold hardening increased the ability of eucalypts to endure extracellular ice formation. The maintenance of photosynthetic capacity in cold-hardened plants may also play a role in their response to freezing.

  17. Costs and benefits of cold acclimation in field released Drosophila

    DEFF Research Database (Denmark)

    Kristensen, Torsten N; Hoffmann, Ary A; Overgaard, Johannes

    2008-01-01

    One way animals can counter the effects of climatic extremes is via physiological acclimation, but acclimating to one extreme might decrease performance under different conditions. Here, we use field releases of Drosophila melanogaster on two continents across a range of temperatures to test...... for costs and benefits of developmental or adult cold acclimation. Both types of cold acclimation had enormous benefits at low temperatures in the field; in the coldest releases only cold-acclimated flies were able to find a resource. However, this advantage came at a huge cost; flies that had not been cold......-acclimated were up to 36 times more likely to find food than the cold-acclimated flies when temperatures were warm. Such costs and strong benefits were not evident in laboratory tests where we found no reduction in heat survival of the cold-acclimated flies. Field release studies, therefore, reveal costs of cold...

  18. Measurements on Active Cold Loads for Radiometer Calibration

    DEFF Research Database (Denmark)

    Skou, Niels; Søbjærg, Sten Schmidl; Balling, Jan E.

    2008-01-01

    Two semi-conductor Active Cold Loads (ACLs) to be used as cold references in spaceborne microwave radiometers have been developed. An X-band frequency was chosen, and the target noise temperature value was in the 50 to 100 K range. The ACLs are characterized in the operating temperature range 0 50...... degrees C, and long term stability is assessed. To this end a Test Bed has been developed. This Test Bed is actually a stable radiometer, and its design is briefly reviewed. The test setup is described, and preliminary test campaign results indicate output temperatures of 77 K and 55 K for the two ACLs...

  19. Measurements on Active Cold Loads for Radiometer Calibration

    DEFF Research Database (Denmark)

    Søbjærg, Sten Schmidl; Skou, Niels; Balling, Jan E.

    2009-01-01

    Two semiconductor active cold loads (ACLs) to be used as cold references in spaceborne microwave radiometers have been developed. An X-band frequency was chosen, and the target noise temperature value was in the 50-100-K range. The ACLs are characterized in the operating temperature range of 0deg......C-50degC, and long-term stability is assessed. To this end, a test bed has been developed. This test bed is actually a stable radiometer, and its design and performance are discussed. The test setup is described, and test campaign results indicate output temperatures of 77 and 56 K for the two ACLs...

  20. Performance Measurements on Active Cold Loads for Radiometer Calibration

    DEFF Research Database (Denmark)

    Skou, Niels; Søbjærg, Sten Schmidl; Balling, Jan E.

    2007-01-01

    Two semi-conductor Active Cold Loads (ACLs) to be used as cold references in spaceborne microwave radiometers have been developed. An X-band frequency has been chosen, and the target noise temperature value is in the 50 to 100 K range. The ACLs are to be characterized in the operating temperature...... range 0-50 degrees C, and long term stability must be assessed. To this end a Test Bed has been developed. This Test Bed is actually a stable radiometer, and its design and development is discussed. The test setup is described, and preliminary test campaign results indicate output temperatures of 73 K...

  1. Understanding Colds: Anatomy of the Nose

    Science.gov (United States)

    ... at least one-half of colds. (5) Cold viruses can only multiply when they are inside of living cells. When on an environmental surface, cold viruses cannot multiply. However, they are still infectious if ...

  2. Inducing Cold-Sensitivity in the Frigophilic Fly Drosophila montana by RNAi.

    Directory of Open Access Journals (Sweden)

    Felipe M Vigoder

    Full Text Available Cold acclimation is a critical physiological adaptation for coping with seasonal cold. By increasing their cold tolerance individuals can remain active for longer at the onset of winter and can recover more quickly from a cold shock. In insects, despite many physiological studies, little is known about the genetic basis of cold acclimation. Recently, transcriptomic analyses in Drosophila virilis and D. montana revealed candidate genes for cold acclimation by identifying genes upregulated during exposure to cold. Here, we test the role of myo-inositol-1-phosphate synthase (Inos, in cold tolerance in D. montana using an RNAi approach. D. montana has a circumpolar distribution and overwinters as an adult in northern latitudes with extreme cold. We assessed cold tolerance of dsRNA knock-down flies using two metrics: chill-coma recovery time (CCRT and mortality rate after cold acclimation. Injection of dsRNAInos did not alter CCRT, either overall or in interaction with the cold treatment, however it did induced cold-specific mortality, with high levels of mortality observed in injected flies acclimated at 5°C but not at 19°C. Overall, injection with dsRNAInos induced a temperature-sensitive mortality rate of over 60% in this normally cold-tolerant species. qPCR analysis confirmed that dsRNA injection successfully reduced gene expression of Inos. Thus, our results demonstrate the involvement of Inos in increasing cold tolerance in D. montana. The potential mechanisms involved by which Inos increases cold tolerance are also discussed.

  3. Pressure field study of the Tevatron cold compressors

    Energy Technology Data Exchange (ETDEWEB)

    Klebaner, A.L.; Martinez, A.; Soyars, W.M.; Theilacker, J.C.; /Fermilab

    2003-01-01

    The Fermilab Tevatron cryogenic system utilizes high-speed centrifugal cold compressors, manufactured by Ishikawajima-Harima Heavy Industries Co. Ltd. (IHI), for high-energy operations [1]. The compressor is designed to pump 60 g/sec of 3.6 K saturated helium vapor at a pressure ratio of 2.8, with an off-design range of 40 to 70 g/sec. Operating speeds are between 40 and 95 krpm, with a speed of 80 krpm at the design point. Different heat loads and magnet quench performance of each of the twenty-four satellite refrigerators dictates different process pressure and flow rates of the cold compressors. Reducing the process flow rate can cause the centrifugal cold compressor to stop pumping and subsequently surge. Tests have been conducted at the Cryogenic Test Facility at Fermilab to map the pressure field and appropriate efficiency of the IHI hydrodynamic cold compressor. The information allows tuning of each of the twenty-four Tevatron satellite refrigerators to avoid cold compressor operation near the surge and choke lines. A new impeller has also been tested. The Tevatron cold compressor pressure field and efficiency data with the new impeller are presented in this paper.

  4. Pressure Field Study of the Tevatron Cold Compressors

    Science.gov (United States)

    Klebaner, A. L.; Martinez, A.; Soyars, W. M.; Theilacker, J. C.

    2004-06-01

    The Fermilab Tevatron cryogenic system utilizes high-speed centrifugal cold compressors, manufactured by Ishikawajima-Harima Heavy Industries Co. Ltd. (IHI), for high-energy operations. The compressor is designed to pump 60 g/sec of 3.6 K saturated helium vapor at a pressure ratio of 2.8, with an off-design range of 40 to 70 g/sec. Operating speeds are between 40,000 and 95,000 rpm, with a speed of 80,000 rpm at the design point. Different heat loads and magnet quench performance of each of the twenty-four satellite refrigerators dictates different process pressure and flow rates of the cold compressors. Reducing the process flow rate can cause the centrifugal cold compressor to stop pumping and subsequently surge. Tests have been conducted at the Cryogenic Test Facility at Fermilab to map the pressure field and appropriate efficiency of the IHI hydrodynamic cold compressor. The information allows tuning of each of the twenty-four Tevatron satellite refrigerators to avoid cold compressor operation near the surge and choke lines. A new impeller has also been tested. The Tevatron cold compressor pressure field and efficiency data with the new impeller are presented in this paper.

  5. Test

    DEFF Research Database (Denmark)

    Bendixen, Carsten

    2014-01-01

    Bidrag med en kortfattet, introducerende, perspektiverende og begrebsafklarende fremstilling af begrebet test i det pædagogiske univers.......Bidrag med en kortfattet, introducerende, perspektiverende og begrebsafklarende fremstilling af begrebet test i det pædagogiske univers....

  6. Crumb Rubber in cold recycled bituminous mixes

    DEFF Research Database (Denmark)

    Dondi, Giulio; Tataranni, Piergiorgio; Pettinari, Matteo

    2014-01-01

    Today recycling is one of the most innovative and interesting techniques for the rehabilitation of destressed road pavements. In recent years the increased interest in this process, has led to the development of various alternative methods for the recovery and the reuse of road bituminous materials....... Cold recycling is, among the recycling techniques, certainly the most studied and developed: it allows the recovering of bituminous material from an existing pavement without the addition of heat, whilst ensuring the creation of high quality bound base layers. A wide range of materials have been tested...... together with Reclaimed Asphalt Pavement (RAP) and, consequently, there is a large number of variables that can be considered in the mix-design process of new eco-friendly Cold Recycled Mixes. In particular, the present research involves the use of Crumb Rubber within a mixture containing 100% Reclaimed...

  7. Draught Risk from Cold Vertical Surfaces

    DEFF Research Database (Denmark)

    Heiselberg, Per

    of the research is to develop expressions for the airflow beyond the floor area, which influences the thermal comfort in the occupied zone. Measurements of velocities and temperatures are carried out in a two-dimensional test case. They show that the characteristics of the flow in the near floor region are very......Glazed facades and atria have had a boom in the 1980's as an architectural feature in building design. Natural convective flows from these cold surfaces are in winter time, however, often the cause of thermal discomfort and there is a need for research to improve the design methods. The objective...... similar to the characteristics of stratified flows. Expressions have been developed for the rate of decrement of the maximum velocity with distance from the surface and for the maximum temperature difference between the cold airflow along the floor and the rest of the occupied zone....

  8. Adiabatic theory for anisotropic cold molecule collisions

    Energy Technology Data Exchange (ETDEWEB)

    Pawlak, Mariusz [Schulich Faculty of Chemistry, Technion–Israel Institute of Technology, Haifa 32000 (Israel); Faculty of Chemistry, Nicolaus Copernicus University in Toruń, Gagarina 7, 87-100 Toruń (Poland); Shagam, Yuval; Narevicius, Edvardas [Department of Chemical Physics, Weizmann Institute of Science, Rehovot 76100 (Israel); Moiseyev, Nimrod [Schulich Faculty of Chemistry, Technion–Israel Institute of Technology, Haifa 32000 (Israel); Faculty of Physics, Technion–Israel Institute of Technology, Haifa 32000 (Israel)

    2015-08-21

    We developed an adiabatic theory for cold anisotropic collisions between slow atoms and cold molecules. It enables us to investigate the importance of the couplings between the projection states of the rotational motion of the atom about the molecular axis of the diatom. We tested our theory using the recent results from the Penning ionization reaction experiment {sup 4}He(1s2s {sup 3}S) + HD(1s{sup 2}) → {sup 4}He(1s{sup 2}) + HD{sup +}(1s) + e{sup −} [Lavert-Ofir et al., Nat. Chem. 6, 332 (2014)] and demonstrated that the couplings have strong effect on positions of shape resonances. The theory we derived provides cross sections which are in a very good agreement with the experimental findings.

  9. Bioremediation of petroleum hydrocarbons in cold regions

    National Research Council Canada - National Science Library

    Barnes, David L; Filler, Dennis M; Snape, Ian

    2008-01-01

    ..., identification and adaptations of cold-tolerant bacteria, contaminant transport in cold soils and permafrost, temperature effects on biodegradation, analytical methods, treatability studies, an...

  10. Observations of cold antihydrogen

    CERN Document Server

    Tan, J N; Gabrielse, G; Oxley, P; Speck, A; Storry, C H; Wessels, M; Grzonka, D; Oelert, W; Schepers, G; Sefzick, T; Walz, J; Pittner, H; Hänsch, T W; Hessels, E A

    2004-01-01

    ATRAP's e/sup +/ cooling of p in a nested Penning trap has led to reports of cold H produced during such cooling by the ATHENA and ATRAP collaborations. To observe H, ATHENA uses coincident annihilation detection and ATRAP uses field ionization followed by p storage. Advantages of ATRAP's field ionization method include the complete absence of any background events, and the first way to measure which H states are produced. ATRAP enhances the H production rate by driving many cycles of e/sup +/ cooling in the nested trap, with more H counted in an hour than the sum of all the other antimatter atoms ever reported. The number of H counted per incident high energy p is also higher than ever observed. The first measured distribution of H states is made using a pre-ionizing electric field between separated production and detection regions. The high rate and the high Rydberg states suggest that the H is formed via three-body recombination, as expected. (22 refs).

  11. Cold Quark Matter

    CERN Document Server

    Kurkela, Aleksi; Vuorinen, Aleksi

    2010-01-01

    We perform an O(alpha_s^2) perturbative calculation of the equation of state of cold but dense QCD matter with two massless and one massive quark flavor, finding that perturbation theory converges reasonably well for quark chemical potentials above 1 GeV. Using a running coupling constant and strange quark mass, and allowing for further non-perturbative effects, our results point to a narrow range where absolutely stable strange quark matter may exist. Absent stable strange quark matter, our findings suggest that quark matter in compact star cores becomes confined to hadrons only slightly above the density of atomic nuclei. Finally, we show that equations of state including quark matter lead to hybrid star masses up to M~2M_solar, in agreement with current observations. For strange stars, we find maximal masses of M~2.75M_solar and conclude that confirmed observations of compact stars with M>2M_solar would strongly favor the existence of stable strange quark matter.

  12. Vaccines for the common cold.

    Science.gov (United States)

    Simancas-Racines, Daniel; Franco, Juan Va; Guerra, Claudia V; Felix, Maria L; Hidalgo, Ricardo; Martinez-Zapata, Maria José

    2017-05-18

    The common cold is a spontaneously remitting infection of the upper respiratory tract, characterised by a runny nose, nasal congestion, sneezing, cough, malaise, sore throat, and fever (usually common cold worldwide is related to its ubiquitousness rather than its severity. The development of vaccines for the common cold has been difficult because of antigenic variability of the common cold virus and the indistinguishable multiple other viruses and even bacteria acting as infective agents. There is uncertainty regarding the efficacy and safety of interventions for preventing the common cold in healthy people. This is an update of a Cochrane review first published in 2011 and previously updated in 2013. To assess the clinical effectiveness and safety of vaccines for preventing the common cold in healthy people. We searched the Cochrane Central Register of Controlled Trials (CENTRAL) (September 2016), MEDLINE (1948 to September 2016), Embase (1974 to September 2016), CINAHL (1981 to September 2016), and LILACS (1982 to September 2016). We also searched three trials registers for ongoing studies and four websites for additional trials (February 2017). We included no language or date restrictions. Randomised controlled trials (RCTs) of any virus vaccines compared with placebo to prevent the common cold in healthy people. Two review authors independently evaluated methodological quality and extracted trial data. We resolved disagreements by discussion or by consulting a third review author. We found no additional RCTs for inclusion in this update. This review includes one RCT dating from the 1960s with an overall high risk of bias. The RCT included 2307 healthy participants, all of whom were included in analyses. This trial compared the effect of an adenovirus vaccine against placebo. No statistically significant difference in common cold incidence was found: there were 13 (1.14%) events in 1139 participants in the vaccines group and 14 (1.19%) events in 1168

  13. Cold-formed steel design

    CERN Document Server

    Yu, Wei-Wen

    2010-01-01

    The definitive text in the field, thoroughly updated and expanded Hailed by professionals around the world as the definitive text on the subject, Cold-Formed Steel Design is an indispensable resource for all who design for and work with cold-formed steel. No other book provides such exhaustive coverage of both the theory and practice of cold-formed steel construction. Updated and expanded to reflect all the important developments that have occurred in the field over the past decade, this Fourth Edition of the classic text provides you with more of the detailed, up-to-the-minute techni

  14. High Flux Isotope Reactor cold neutron source reference design concept

    Energy Technology Data Exchange (ETDEWEB)

    Selby, D.L.; Lucas, A.T.; Hyman, C.R. [and others

    1998-05-01

    In February 1995, Oak Ridge National Laboratory`s (ORNL`s) deputy director formed a group to examine the need for upgrades to the High Flux Isotope Reactor (HFIR) system in light of the cancellation of the Advanced neutron Source Project. One of the major findings of this study was that there was an immediate need for the installation of a cold neutron source facility in the HFIR complex. In May 1995, a team was formed to examine the feasibility of retrofitting a liquid hydrogen (LH{sub 2}) cold source facility into an existing HFIR beam tube. The results of this feasibility study indicated that the most practical location for such a cold source was the HB-4 beam tube. This location provides a potential flux environment higher than the Institut Laue-Langevin (ILL) vertical cold source and maximizes the space available for a future cold neutron guide hall expansion. It was determined that this cold neutron beam would be comparable, in cold neutron brightness, to the best facilities in the world, and a decision was made to complete a preconceptual design study with the intention of proceeding with an activity to install a working LH{sub 2} cold source in the HFIR HB-4 beam tube. During the development of the reference design the liquid hydrogen concept was changed to a supercritical hydrogen system for a number of reasons. This report documents the reference supercritical hydrogen design and its performance. The cold source project has been divided into four phases: (1) preconceptual, (2) conceptual design and testing, (3) detailed design and procurement, and (4) installation and operation. This report marks the conclusion of the conceptual design phase and establishes the baseline reference concept.

  15. Healthy snacks at the checkout counter: a lab and field study on the impact of shelf arrangement and assortment structure on consumer choices.

    Science.gov (United States)

    van Kleef, Ellen; Otten, Kai; van Trijp, Hans C M

    2012-12-12

    The essence of nudging is to adapt the environment in which consumers make decisions to help them make better choices, without forcing certain outcomes upon them. To determine how consumers can effectively be guided to select healthier snacks, we examine the effect of manipulating the assortment structure and shelf layout of an impulse display including both healthy and unhealthy snacks near the checkout counter of a canteen. Both a lab and field study applied a two-factor experimental design manipulating snack offerings both in an on-screen choice environment and a natural environment (hospital staff restaurant). Shelf arrangement (i.e. accessibility) was altered by putting healthy snacks at higher shelves versus lower shelves. Assortment structure (i.e. availability) was altered by offering an assortment that either included 25% or 75% healthy snacks. Participants in the lab study (n = 158) made a choice from a shelf display. A brief survey following snack selection asked participants to evaluate the assortment and their choice. The field experiment took place in a hospital canteen. Daily sales data were collected for a period of four weeks. On completion of the field study, employees (n = 92) filled out a questionnaire about all four displays and rated their attractiveness, healthiness and perceived freedom of choice. The lab study showed a higher probability of healthy snack choice when 75% of the assortment consisted of healthy snacks compared to conditions with 25% healthy snack assortments, even though choices were not rated less satisfying or more restrictive. Regarding shelf display location of healthy snacks, no significant differences were observed. There was also no significant shelf arrangement by assortment structure interactive effect. The field study replicated these findings, in that this assortment structure led to higher sales of healthy snacks. Sales of unhealthy and total snacks were not impacted by manipulations (no main or interaction effects

  16. Winter Storms and Extreme Cold

    Science.gov (United States)

    ... container with water and place them in the freezer to help keep food cold. A NOAA Weather ... exposures will eventually use up your body’s stored energy, which leads to lower body temperature. Warnings signs ...

  17. Literature review: the common cold.

    Science.gov (United States)

    Hilding, D A

    1994-09-01

    Most colds are caused by rhinovirus infection, perhaps facilitated by chilling or stress. Virus infection begins in the nasopharynx and causes spotty destruction of the nasal ciliated epithelium. Transmission occurs chiefly via droplets of various sizes transported through the air, but some types of virus persist in moist secretions on handled objects and may retain their infectiousness. Living in crowded, poorly-ventilated quarters facilitates transmission. Not many virus particles survive in saliva and it is difficult to infect via the lips or mouth. Kissing does not efficiently spread cold infection. Prophylactic treatment with interferon does not protect against cold infection. Aspirin and acetaminophen reduced serum antibody response and increased nasal symptoms in a controlled Australian study. The combination of intranasal interferon and ipratropium with oral naproxen gave promising results in experimental rhinovirus inoculation. Basically, there has been little or no progress towards effective cold treatment in the past century.

  18. Magnesium Repair by Cold Spray

    National Research Council Canada - National Science Library

    Champagne, V. K; Leyman, P.F; Helfritch, D. J

    2008-01-01

    .... Army Research Laboratory has developed a cold spray process to reclaim magnesium components that shows significant improvement over existing methods and is in the process of qualification for use on rotorcraft...

  19. Facts about the Common Cold

    Science.gov (United States)

    ... different viruses. Rhinovirus is the most common cause, accounting for 10 to 40 percent of colds. Other ... Of Use | Privacy Our Family Of Sites nonprofit software Join the fight for healthy lungs and healthy ...

  20. Phonon forces and cold denaturatio

    DEFF Research Database (Denmark)

    Bohr, Jakob

    2003-01-01

    Protein unfolds upon temperature reduction as Well as upon In increase in temperature, These phenomena are called cold denaturation and hot denaturation, respectively. The contribution from quantum mode forces to denaturation is estimated using a simple phenomenological model describing the molec......Protein unfolds upon temperature reduction as Well as upon In increase in temperature, These phenomena are called cold denaturation and hot denaturation, respectively. The contribution from quantum mode forces to denaturation is estimated using a simple phenomenological model describing...

  1. Cold and L-menthol-induced sensitization in healthy volunteers--a cold hypersensitivity analogue to the heat/capsaicin model.

    Science.gov (United States)

    Andersen, Hjalte H; Poulsen, Jeppe N; Uchida, Yugo; Nikbakht, Anahita; Arendt-Nielsen, Lars; Gazerani, Parisa

    2015-05-01

    Topical high-concentration L-menthol is the only established human experimental pain model to study mechanisms underlying cold hyperalgesia. We aimed at investigating the combinatorial effect of cold stimuli and topical L-menthol on cold pain and secondary mechanical hyperalgesia. Analogue to the heat-capsaicin model on skin sensitization, we proposed that cold/menthol enhances or prolong L-menthol-evoked sensitization. Topical 40% L-menthol or vehicle was applied (20 minutes) on the volar forearms of 20 healthy females and males (age, 28.7 ± 0.6 years). Cold stimulation of 5°C for 5 minutes was then applied to the treated area 3 times with 40-minute intervals. Cold detection threshold and pain, mechanical hyperalgesia (pinprick), static and dynamic mechanical allodynia (von Frey and brush), skin blood flow (laser speckle), and temperature (thermocamera) were assessed. Cold detection threshold and cold pain threshold (CPT) increased after L-menthol and remained high after the cold rekindling cycles (P menthol evoked secondary hyperalgesia to pinprick (P menthol (P menthol facilitated and prolonged L-menthol-induced cold pain and hyperalgesia. This model may prove beneficial for testing analgesic compounds when a sufficient duration of time is needed to see drug effects on CPT or mechanical hypersensitivity.

  2. A characteristic scale for cold gas

    Science.gov (United States)

    McCourt, Michael; Oh, S. Peng; O'Leary, Ryan; Madigan, Ann-Marie

    2018-02-01

    We find that clouds of optically thin, pressure-confined gas are prone to fragmentation as they cool below ∼106 K. This fragmentation follows the lengthscale ∼cstcool, ultimately reaching very small scales (∼0.1 pc/n), as they reach the temperature ∼104 K at which hydrogen recombines. While this lengthscale depends on the ambient pressure confining the clouds, we find that the column density through an individual fragment Ncloudlet ∼ 1017 cm-2 is essentially independent of environment; this column density represents a characteristic scale for atomic gas at 104 K. We therefore suggest that 'clouds' of cold, atomic gas may, in fact, have the structure of a mist or a fog, composed of tiny fragments dispersed throughout the ambient medium. We show that this scale emerges in hydrodynamic simulations, and that the corresponding increase in the surface area may imply rapid entrainment of cold gas. We also apply it to a number of observational puzzles, including the large covering fraction of diffuse gas in galaxy haloes, the broad-line widths seen in quasar and AGN spectra and the entrainment of cold gas in galactic winds. While our simulations make a number of assumptions and thus have associated uncertainties, we show that this characteristic scale is consistent with a number of observations, across a wide range of astrophysical environments. We discuss future steps for testing, improving and extending our model.

  3. Superheavy nuclei–cold synthesis and structure

    Indian Academy of Sciences (India)

    The quantum mechanical fragmentation theory (QMFT), given for the cold synthesis of new and superheavy elements, is reviewed and the use of radioactive nuclear beams (RNB) and targets (RNT) is discussed. The QMFT is a complete theory of cold nuclear phenomena, namely, the cold fission, cold fusion and cluster ...

  4. Cold storage of rooted and non-rooted carnation cuttings ...

    African Journals Online (AJOL)

    showed differences depending on the cultivar tested. Specifically, the Vittorio cultivar had a better reaction to long-term storage. The survival and rooting rates of non-rooted cuttings after cold storage also showed differences depending on the cultivar tested. Vittorio cultivar reacted better to storage than the Dianora cultivar.

  5. Hot and cold executive functions in pure opioid users undergoing ...

    African Journals Online (AJOL)

    Methods: Hot executive functions including decision‑making and emotion recognition were assessed using the Iowa gambling task and Ekman faces test, whereas cold executive functions including working memory (WM), cognitive flexibility, and response inhibition were assessed using n‑back, Wisconsin card sorting test, ...

  6. Developments of New Lubricants for Cold Forging of Stainless Steel

    DEFF Research Database (Denmark)

    Steenberg, Thomas; Christensen, Erik; Olesen, P.

    1997-01-01

    Two new lubricant systems for cold forging of stainless steel have been developed. The main component of these systems are FeCl3 and ZnCa2(PO4)2, respectively. Both lubricant systems have been tested using a backward extrusion test. The results show excellent lubricating properties with respect...

  7. Temporal characteristics of cold pain perception.

    Science.gov (United States)

    Frölich, Michael A; Bolding, Mark S; Cutter, Gary R; Ness, Timothy J; Zhang, Kui

    2010-08-09

    Adaptation to a sustained stimulus is an important phenomenon in psychophysical experiments. When studying the response to an experimental task, the investigator has to account for the change in perceived stimulus intensity with repeated stimulus application and, if the stimulus is sustained, for the change in intensity during the presentation. An example of a sustained stimulus is the cold pressor task (CPT). The task has been used both as an experimental pain task and to study cardiovascular physiology. In functional imaging research, the CPT has been used to evaluate cognitive processing of a noxious stimulus. Investigators typically model the stimulus in a block design as a categorical (on-off) stimulus and do not account for a temporal change in stimulus perception. If the perceived stimulus changes over time, the results may be misleading. Therefore, we characterized the time course of cold pain in human volunteers and developed a model of the temporal characteristics of perceived cold pain. Fifteen healthy participants underwent cold pain testing by immersing their right foot into a container filled with ice water (2 degrees C) for 30s alternating with a 30s immersion into a container filled with tepid water 32 degrees C (control). Participants rated the pain intensity using an electronic slide algometer. Using a mixed general linear model (effectively a polynomial regression model), we determined that pain ratings follow a crescendo-decrescendo pattern that can be described well using a quadratic model. We conclude that the time course of quantitative perception differs fundamentally from the time course of stimulus presentation. This may be important when looking for the physiological correlates of perception as opposed to the presence of a stimulus per se. Copyright 2010 Elsevier Ireland Ltd. All rights reserved.

  8. Garlic for the common cold.

    Science.gov (United States)

    Lissiman, Elizabeth; Bhasale, Alice L; Cohen, Marc

    2014-11-11

    Background Garlic is alleged to have antimicrobial and antiviral properties that relieve the common cold, among other beneficial effects. There is widespread usage of garlic supplements. The common cold is associated with significant morbidity and economic consequences. On average, children have six to eight colds per year and adults have two to four.Objectives To determine whether garlic (Allium sativum) is effective for the prevention or treatment of the common cold, when compared to placebo, no treatment or other treatments.Search methods We searched CENTRAL (2014, Issue 7),OLDMEDLINE (1950 to 1965),MEDLINE (January 1966 to July week 5, 2014), EMBASE(1974 to August 2014) and AMED (1985 to August 2014).Selection criteria Randomised controlled trials of common cold prevention and treatment comparing garlic with placebo, no treatment or standard treatment.Data collection and analysis Two review authors independently reviewed and selected trials from searches, assessed and rated study quality and extracted relevant data.Main results In this updated review, we identified eight trials as potentially relevant from our searches. Again, only one trial met the inclusion criteria.This trial randomly assigned 146 participants to either a garlic supplement (with 180 mg of allicin content) or a placebo (once daily)for 12 weeks. The trial reported 24 occurrences of the common cold in the garlic intervention group compared with 65 in the placebo group (P value garlic group compared with the placebo group (111 versus 366). The number of days to recovery from an occurrence of the common cold was similar in both groups (4.63 versus 5.63). Only one trial met the inclusion criteria, therefore limited conclusions can be drawn. The trial relied on self reported episodes of the common cold but was of reasonable quality in terms of randomisation and allocation concealment. Adverse effects included rash and odour. Authors' conclusions There is insufficient clinical trial evidence

  9. Finger and toe temperatures on exposure to cold water and cold air

    NARCIS (Netherlands)

    van der Struijs, N.R.; van Es, E.M.; Raymann, R.J.; Daanen, H.A.M.

    2008-01-01

    Introduction: Subjects with a weak cold-induced vasodilatation response (CIVD) to experimental cold-water immersion of the fingers in a laboratory setting have been shown to have a higher risk for local cold injuries when exposed to cold in real life. Most of the cold injuries in real life, however,

  10. Finger and toe temperature response to cold water and cold air exposure

    NARCIS (Netherlands)

    Struijs, N.R. van der; Es, E.M. van; Raymann, R.J.E.M.; Daanen, H.A.M.

    2008-01-01

    Introduction: Subjects with a weak cold-induced vasodilatation response (CIVD) to experimental cold-water immersion of the fingers in a laboratory setting have been shown to have a higher risk for local cold injuries when exposed to cold in real life. Most of the cold injuries in real life, however,

  11. Impact of cold temperature on Euro 6 passenger car emissions.

    Science.gov (United States)

    Suarez-Bertoa, Ricardo; Astorga, Covadonga

    2017-11-27

    Hydrocarbons, CO, NOx, NH3, N2O, CO2 and particulate matter emissions affect air quality, global warming and human health. Transport sector is an important source of these pollutants and high pollution episodes are often experienced during the cold season. However, EU vehicle emissions regulation at cold ambient temperature only addresses hydrocarbons and CO vehicular emissions. For that reason, we have studied the impact that cold ambient temperatures have on Euro 6 diesel and spark ignition (including: gasoline, ethanol flex-fuel and hybrid vehicles) vehicle emissions using the World-harmonized Light-duty Test Cycle (WLTC) at -7 °C and 23 °C. Results indicate that when facing the WLTC at 23 °C the tested vehicles present emissions below the values set for type approval of Euro 6 vehicles (still using NEDC), with the exception of NOx emissions from diesel vehicles that were 2.3-6 times higher than Euro 6 standards. However, emissions disproportionally increased when vehicles were tested at cold ambient temperature (-7 °C). High solid particle number (SPN) emissions (>1 × 1011 # km-1) were measured from gasoline direct injection (GDI) vehicles and gasoline port fuel injection vehicles. However, only diesel and GDI SPN emissions are currently regulated. Results show the need for a new, technology independent, procedure that enables the authorities to assess pollutant emissions from vehicles at cold ambient temperatures. Harmful pollutant emissions from spark ignition and diesel vehicles are strongly and negatively affected by cold ambient temperatures. Only hydrocarbon, CO emissions are currently regulated at cold temperature. Therefore, it is of great importance to revise current EU winter vehicle emissions regulation. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.

  12. Cold Spray Repair of Martensitic Stainless Steel Components

    Science.gov (United States)

    Faccoli, M.; Cornacchia, G.; Maestrini, D.; Marconi, G. P.; Roberti, R.

    2014-12-01

    The possibility of using cold spray as repair technique of martensitic stainless steel components was evaluated through laboratory investigations. An austenitic stainless steel feedstock powder was chosen, instead of soft metals powders like nickel, copper, or aluminum, used for repairing components made in light alloy or cast iron. The present study directly compares the microstructure, the residual stresses, and the micro-hardness of repairs obtained by cold spray and by TIG welding, that is commonly used as repair technique in large steel components. XRD and optical metallographic analysis of the repairs showed that cold spray offers some advantages, inducing compressive residual stresses in the repair and avoiding alterations of the interface between repair and base material. For these reasons, a heat treatment after the cold spray repair is not required to restore the base material properties, whereas a post-weld heat treatment is needed after the welding repair. Cold spray repair also exhibits a higher micro-hardness than the welding repair. In addition, the cavitation erosion resistance of a cold spray coating was investigated through ultrasonic cavitation tests, and the samples worn surfaces were observed by scanning electron microscopy.

  13. Joint and column behaviour of slotted cold-formed steel studs

    DEFF Research Database (Denmark)

    Andreassen, Michael Joachim; Jönsson, Jeppe

    2015-01-01

    Slotted cold-formed steel studs are used in loadbearing external plasterboard walls. The cold-formed steel studs in these walls are supported by and joined to track sections at the top and the bottom. This paper describes the compression testing of the loadbearing studs in order to observe...... with and without web stiffeners, in order to establish the influence of these on the joint behaviour and loadbearing capacity of the slotted cold-formed steel studs....

  14. Relationship Between Storage and Recording with Quality of DPT Vaccine Cold Chain in Puskesmas

    Directory of Open Access Journals (Sweden)

    Faradiba Hikmarida

    2014-09-01

    Full Text Available ABSTRACT Increasing number of diphteria cases in Sidoarjo Regency, with occurrence of cases in those who had received DPT immunization shows the existence of problem concerning to immunization. The efficacy itself, depends on the quality of vaccines given. Insufficiency in cold chain may lower the quality of DPT vaccines. The purpose of this study was to analyze relationship between DPT vaccine storage and recording for DPT vaccines cold chain with quality of DPT vaccine cold chain in puskesmas Sidoarjo Regency. This research is a descriptive research with cross sectional design. Sample used were total population, which includes all 26 puskesmas within Sidoarjo. The variables were DPT vaccine storage, recording for DPT vaccines cold chain and quality of DPT vaccine cold chain. The result of this study showed that DPT vaccine storage was good (58%, recording for DPT vaccines cold chain were insufficient (77%, and quality of DPT vaccine cold chain in puskesmas was also good (62%. Spearman correlation test showed relationship between DPT vaccine storage and quality of DPT vaccine cold chain in Puskesmas was strong and positive (r = 0,561. Relationship between recording for DPT vaccines cold chain and quality of DPT vaccine cold chain in puskesmas was moderate and positive (r = 0,421. the better the storage for DPT vaccines and recording for DPT vaccines cold chain in puskesmas, the better its cold chain quality in puskesmas. Improvement in officers’ obedience in storing DPT vaccine and its recording concerning to the cold chain which appropriate according to procedures, were really needed. Keywords: storage, recording, quality, cold chain, DPT vaccine

  15. Desensitization of menthol-activated cold receptors in lower extremities during local cooling in young women with a cold constitution.

    Science.gov (United States)

    Yamazaki, Fumio; Sone, Ryoko

    2017-03-01

    To test the hypothesis that topical menthol-induced reactivity of cold sensation and cutaneous vasoconstriction to local cooling is augmented in individuals with a cold constitution, we examined thermal sensation and cutaneous vasoconstrictor responses at menthol-treated and untreated sites in the legs during local skin cooling in young women complaining of chilliness (C group) and young women with no complaint as a normal control group (N group). During local skin cooling, the sensitivity to cold sensation was greater in the C group than in the N group. The application of menthol enhanced the cold sensation at a low temperature in the N group, but not in the C group. Cutaneous vasoconstrictor responses to local skin cooling were not altered by menthol treatment in either of the two groups. These findings suggest the desensitization of menthol-activated cold receptors in the legs of C group subjects, and a minor role of cold receptor activity in cutaneous vasoconstrictor response to local cooling.

  16. COLD-SAT dynamic model

    Science.gov (United States)

    Adams, Neil S.; Bollenbacher, Gary

    1992-01-01

    This report discusses the development and underlying mathematics of a rigid-body computer model of a proposed cryogenic on-orbit liquid depot storage, acquisition, and transfer spacecraft (COLD-SAT). This model, referred to in this report as the COLD-SAT dynamic model, consists of both a trajectory model and an attitudinal model. All disturbance forces and torques expected to be significant for the actual COLD-SAT spacecraft are modeled to the required degree of accuracy. Control and experimental thrusters are modeled, as well as fluid slosh. The model also computes microgravity disturbance accelerations at any specified point in the spacecraft. The model was developed by using the Boeing EASY5 dynamic analysis package and will run on Apollo, Cray, and other computing platforms.

  17. Nanofriction in cold ion traps.

    Science.gov (United States)

    Benassi, A; Vanossi, A; Tosatti, E

    2011-01-01

    Sliding friction between crystal lattices and the physics of cold ion traps are so far non-overlapping fields. Two sliding lattices may either stick and show static friction or slip with dynamic friction; cold ions are known to form static chains, helices or clusters, depending on the trapping conditions. Here we show, based on simulations, that much could be learnt about friction by sliding, through, for example, an electric field, the trapped ion chains over a corrugated potential. Unlike infinite chains, in which the theoretically predicted Aubry transition to free sliding may take place, trapped chains are always pinned. Yet, a properly defined static friction still vanishes Aubry-like at a symmetric-asymmetric structural transition, found for decreasing corrugation in both straight and zig-zag trapped chains. Dynamic friction is also accessible in ringdown oscillations of the ion trap. Long theorized static and dynamic one-dimensional friction phenomena could thus become accessible in future cold ion tribology.

  18. Vitamin C for preventing and treating the common cold.

    Science.gov (United States)

    Hemilä, Harri; Chalker, Elizabeth

    2013-01-31

    ). No consistent effect of vitamin C was seen on the duration or severity of colds in the therapeutic trials.The majority of included trials were randomised, double-blind trials. The exclusion of trials that were either not randomised or not double-blind had no effect on the conclusions. The failure of vitamin C supplementation to reduce the incidence of colds in the general population indicates that routine vitamin C supplementation is not justified, yet vitamin C may be useful for people exposed to brief periods of severe physical exercise. Regular supplementation trials have shown that vitamin C reduces the duration of colds, but this was not replicated in the few therapeutic trials that have been carried out. Nevertheless, given the consistent effect of vitamin C on the duration and severity of colds in the regular supplementation studies, and the low cost and safety, it may be worthwhile for common cold patients to test on an individual basis whether therapeutic vitamin C is beneficial for them. Further therapeutic RCTs are warranted.

  19. Cold-start link prediction in multi-relational networks

    Science.gov (United States)

    Wu, Shun-yao; Zhang, Qi; Wu, Mei

    2017-10-01

    During the last decade, interaction data have accumulated exponentially in many fields and provide a new opportunity for cold start link prediction. It seems necessarily to take full advantages of diversified information. However, correlation between different interactions has to be pre-tested. Therefore, this paper abstracts complex systems as multi-relational networks, and employs latent space network model to extract low-dimensional factors of sub-networks and adopts likelihood ratio test to examine correlation between factors. Then, regression between target sub-networks and correlated auxiliary sub-networks could be established for cold start link prediction. Experiments on 8 bioinformatic data sets validate the effectiveness and potential of our strategy for network correlation analysis and cold-start link prediction.

  20. Cold Tolerance of Plants Used for Cold-Regions Revegetation

    Science.gov (United States)

    1990-10-01

    from tempted to transfer the rye cold-tolerance genome to increased concentrations of solutes in cells and extra- wheat in hybrids. While the gene...Journal, 76: 516-517. Tryon, E.H. and R.P. True (1952) Blister shake of Yelenosky, G. (1988) Capacity of citrus flowers to yellow poplar. Bulletin of the

  1. Thermoregulatory and Immune Responses During Cold Exposure: Effects of Repeated Cold Exposure and Acute Exercise

    National Research Council Canada - National Science Library

    Castellani, John

    2000-01-01

    .... This information will be used in developing thermoregulatory models during cold exposure. During these studies several unanswered questions regarding thermoregulation in the cold were also addressed: (1...

  2. Do delayed prescriptions reduce the use of antibiotics for the common cold? A single-blind controlled trial

    National Research Council Canada - National Science Library

    Arroll, B; Kenealy, T; Kerse, N

    2002-01-01

    To test the use of a delayed prescription compared with instructions to take antibiotics immediately in patients presenting to family physicians with upper respiratory tract infections (common colds...

  3. Avionics Box Cold Plate Damage Prevention

    Science.gov (United States)

    Stambolian, Damon B.; Larchar, Steven W.; Henderson, Gena; Tran, Donald; Barth, Tim

    2012-01-01

    Problem Introduction: 1. Prevent Cold Plate Damage in Space Shuttle. 1a. The number of cold plate problems had increased from an average of 16.5 per/year between 1990 through 2000, to an average of 39.6 per year between 2001through 2005. 1b. Each complete set of 80 cold plates cost approximately $29 million, an average of $362,500 per cold plate. 1c It takes four months to produce a single cold plate. 2. Prevent Cold Plate Damage in Future Space Vehicles.

  4. Connections Between Cold Air Pools and Mountain Valley Fog Events in Salt Lake City

    Science.gov (United States)

    Chachere, Catherine N.; Pu, Zhaoxia

    2016-09-01

    The aim of this study is to investigate the connection between cold air pools and fog events in Salt Lake City, Utah, United States. Statistical analyses are conducted using soundings and reported automated surface observing system data from Salt Lake International Airport for the last eighteen cold seasons (October to March, during 1997-2015). A Chi-square test of independence is performed on identified cold air pool, and fog events to determine whether the two events are correlated. Conditional probabilities are then computed to investigate the occurrence of fog, given the presence of a cold pool. These probabilities are compared against that of random fog generation in the mid-winter. It is concluded that the dependence between cold air pools and fog events is statistically significant. The presence of a cold pool makes the formation of fog more likely than random generation.

  5. Predicting effects of cold shock: modeling the decline of a thermal plume

    Energy Technology Data Exchange (ETDEWEB)

    Becker, C.D.; Trent, D.S.; Schneider, M.J.

    1977-10-01

    Predicting direct impact of cold shock on aquatic organisms after termination of power plant thermal discharges requires thermal tests that provide quantitative data on the resistance of acclimated species to lower temperatures. Selected examples from the literature on cold shock resistance of freshwater and marine fishes are illustrated to show predictive use. Abrupt cold shock data may be applied to field situations involving either abrupt or gradual temperature declines but yield conservative estimates under the latter conditions. Gradual cold shock data may be applied where heated plumes gradually dissipate because poikilotherms partially compensate for lowering temperature regimes. A simplified analytical model is presented for estimating thermal declines in terminated plumes originating from offshore, submerged discharges where shear current and boundary effects are minimal. When applied to site-specific conditions, the method provides time-temperature distributions for correlation with cold resistance data and, therefore, aids in assessing cold shock impact on aquatic biota.

  6. "Stone Cold": Worthy of Study?

    Science.gov (United States)

    Douthwaite, Alison

    2015-01-01

    This article draws on my experiences of teaching "Stone Cold" to respond to a blog post suggesting that the novel holds little educational value. I argue that the novel's narrative style helps to foster criticality while its subject matter can help students see the relevance of literature to the world around them. Relating this to…

  7. Talking resolved the cold war

    National Research Council Canada - National Science Library

    Kiger, Carol

    2015-01-01

    ... nuclear nation. Historians will remind us that, in the midst of the Cold War with a nuclear arms race between the United States and the former U.S.S.R., the top leaders, Reagan and Gorbachev (who had little reason to trust each other), met in Reykjavik, Iceland, and discussed the reduction of nuclear weapons. The result of their talks was t...

  8. Encyclopedia of the Cold War

    NARCIS (Netherlands)

    van Dijk, R.

    2008-01-01

    Between 1945 and 1991, tension between the USA, its allies, and a group of nations led by the USSR, dominated world politics. This period was called the Cold War - a conflict that stopped short to a full-blown war. Benefiting from the recent research of newly open archives, the Encyclopedia of the

  9. Improved Windows for Cold Climates

    DEFF Research Database (Denmark)

    Laustsen, Jacob Birck; Svendsen, Svend

    2005-01-01

    important. In the heating season in cold climates the solar gain through windows can be utilized for space heating which results in a corresponding reduction in the energy production that is often based on fossil fuels. A suitable quantity for evaluating the energy performance of windows in a simple...

  10. Cold War Geopolitics: Embassy Locations.

    Science.gov (United States)

    Vogeler, Ingolf

    1995-01-01

    Asserts that the geopolitics of the Cold War can be illustrated by the diplomatic ties among countries, particularly the superpowers and their respective allies. Describes a classroom project in which global patterns of embassy locations are examined and compared. Includes five maps and a chart indicating types of embassy locations. (CFR)

  11. EDITORIAL: Cold Quantum GasesEditorial: Cold Quantum Gases

    Science.gov (United States)

    Vassen, W.; Hemmerich, A.; Arimondo, E.

    2003-04-01

    This Special Issue of Journal of Optics B: Quantum and Semiclassical Optics brings together the contributions of various researchers working on theoretical and experimental aspects of cold quantum gases. Different aspects of atom optics, matter wave interferometry, laser manipulation of atoms and molecules, and production of very cold and degenerate gases are presented. The variety of subjects demonstrates the steadily expanding role associated with this research area. The topics discussed in this issue, extending from basic physics to applications of atom optics and of cold atomic samples, include: bulletBose--Einstein condensation bulletFermi degenerate gases bulletCharacterization and manipulation of quantum gases bulletCoherent and nonlinear cold matter wave optics bulletNew schemes for laser cooling bulletCoherent cold molecular gases bulletUltra-precise atomic clocks bulletApplications of cold quantum gases to metrology and spectroscopy bulletApplications of cold quantum gases to quantum computing bulletNanoprobes and nanolithography. This special issue is published in connection with the 7th International Workshop on Atom Optics and Interferometry, held in Lunteren, The Netherlands, from 28 September to 2 October 2002. This was the last in a series of Workshops organized with the support of the European Community that have greatly contributed to progress in this area. The scientific part of the Workshop was managed by A Hemmerich, W Hogervorst, W Vassen and J T M Walraven, with input from members of the International Programme Committee who are listed below. The practical aspects of the organization were ably handled by Petra de Gijsel from the Vrije Universiteit in Amsterdam. The Workshop was funded by the European Science Foundation (programme BEC2000+), the European Networks 'Cold Quantum Gases (CQG)', coordinated by E Arimondo, and 'Cold Atoms and Ultraprecise Atomic Clocks (CAUAC)', coordinated by J Henningsen, by the German Physical Society (DFG), by

  12. Cold denaturation of monoclonal antibodies

    Science.gov (United States)

    Lazar, Kristi L; Patapoff, Thomas W

    2010-01-01

    The susceptibility of monoclonal antibodies (mAbs) to undergo cold denaturation remains unexplored. In this study, the phenomenon of cold denaturation was investigated for a mAb, mAb1, through thermodynamic and spectroscopic analyses. tryptophan fluorescence and circular dichroism (CD) spectra were recorded for the guanidine hydrochloride (GuHCl)-induced unfolding of mAb1 at pH 6.3 at temperatures ranging from −5 to 50°C. A three-state unfolding model incorporating the linear extrapolation method was fit to the fluorescence data to obtain an apparent free energy of unfolding, ΔGu, at each temperature. CD studies revealed that mAb1 exhibited polyproline II helical structure at low temperatures and at high GuHCl concentrations. the Gibbs-Helmholtz expression fit to the ΔGu versus temperature data from fluorescence gave a ΔCp of 8.0 kcal mol−1 K−1, a maximum apparent stability of 23.7 kcal mol−1 at 18°C, and an apparent cold denaturation temperature (TCD) of −23°C. ΔGu values for another mAb (mAb2) with a similar framework exhibited less stability at low temperatures, suggesting a depressed protein stability curve and a higher relative TCD. Direct experimental evidence of the susceptibility of mAb1 and mAb2 to undergo cold denaturation in the absence of denaturant was confirmed at pH 2.5. thus, mAbs have a potential to undergo cold denaturation at storage temperatures near −20°C (pH 6.3), and this potential needs to be evaluated independently for individual mAbs. PMID:20093856

  13. Common cold - how to treat at home

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/patientinstructions/000466.htm Common cold - how to treat at home To use the ... Antibiotics are almost never needed to treat a common cold. Acetaminophen (Tylenol) and ibuprofen (Advil, Motrin) help lower ...

  14. Vitamin C and the Common Cold Revisited.

    Science.gov (United States)

    Travis, H. Richard

    1984-01-01

    Various studies indicate that Vitamin C does not prevent or cure a cold, but it may ameliorate symptoms in some individuals. The development of a balanced life-style is more effective towards cold prevention. (DF)

  15. Center for Cold Spray Research and Development

    Data.gov (United States)

    Federal Laboratory Consortium — This is the only DoD facility capable of cold spray research and development, production, and field-repair. It features three stationary cold spray systems used for...

  16. Synthesis of Cold Antihydrogen in a Cusp Trap

    CERN Document Server

    Enomoto, Y; Michishio, K; Kim, C H; Higaki,H; Nagata, Y; Kanai, Y; Torii, H A; Corradini, M; Leali, M; Lodi-Rizzini, E; Mascagna, V; Venturelli, L; Zurlo, N; Fujii, K; Ohtsuka, M; Tanaka, K; Imao, H; Nagashima, Y; Matsuda, Y; Juhász, B; Mohri, A; Yamazaki, Y

    2010-01-01

    We report here the first successful synthesis of cold antihydrogen atoms employing a cusp trap, which consists of a superconducting anti-Helmholtz coil and a stack of multiple ring electrodes. This success opens a new path to make a stringent test of the CPT symmetry via high precision microwave spectroscopy of ground-state hyperfine transitions of antihydrogen atoms.

  17. Fatigue in cold-forging dies: Tool life analysis

    DEFF Research Database (Denmark)

    Skov-Hansen, P.; Bay, Niels; Grønbæk, J.

    1999-01-01

    In the present investigation it is shown how the tool life of heavily loaded cold-forging dies can be predicted. Low-cycle fatigue and fatigue crack growth testing of the tool materials are used in combination with finite element modelling to obtain predictions of tool lives. In the models...

  18. Evaluation of measles vaccine cold chain in Lagos State, Nigeria ...

    African Journals Online (AJOL)

    The National (level 1), State (L2), and Local government vaccine cold stores (L3) as well as some vaccination centres (L4) were physically inspected in Lagos State, Nigeria and the potency of the live-attenuated measles vaccine was tested. Both the L1 and L2 storage facilities were formally adequately equipped and ...

  19. Vasoconstrictor response to cold in forestry workers: a prospective study

    DEFF Research Database (Denmark)

    Olsen, N; Nielsen, S L

    1988-01-01

    ): no symptoms in 1978 and stopped sawing before 1983; group C (n = 12): vibration induced white finger (VWF) in 1978. A cold provocation test measuring the finger systolic blood pressure with a cuff and strain gauge technique during combined body cooling and finger cooling to 30 degrees, 15 degrees, and 6...

  20. Seizing market shaping opportunities for vaccine cold chain equipment.

    Science.gov (United States)

    Azimi, Tara; Franzel, Lauren; Probst, Nina

    2017-04-19

    Gavi, the Vaccine Alliance, supports immunisation programmes in eligible countries to reach children with lifesaving vaccines. Dramatic improvement in the scale and performance of current cold chain systems is required to extend the reach of immunisation services - especially for children living in remote locations - to advance progress towards full vaccine coverage. Achieving these improvements will require a healthier market for cold chain equipment where the products meet user needs, are sustainably priced, and are available in sufficient quantities to meet demand. Yet evidence suggests that the cold chain market has suffered from several failures including limited demand visibility, fragmented procurement, and insufficient information exchange between manufacturers and buyers on needs and equipment performance. One of Gavi's strategic goals is to shape markets for vaccines and other immunisation products, including cold chain equipment and in 2015, Gavi created a new mechanism - the Cold Chain Equipment (CCE) Optimisation Platform - to strengthen country cold chain systems by offering financial support and incentives for higher performing CCE. The main objective of the CCE Platform is to get more equipment that is efficient, sustainable, and better performing deployed to every health facility where it is required at an affordable price. To achieve these objectives, Gavi is putting in place tested market shaping approaches and tools adapted for the CCE market: the development of market strategies or 'roadmaps'; improvement of product performance through the development of target product profiles (TPPs); strategic engagement with CCE manufacturers and countries to enhance information sharing; and tailoring procurement tactics to the CCE market. These approaches and tools will allow for increased demand and supply of higher-performing, cost-effective and quality products. By strengthening immunisation systems with improved cold chain equipment, Gavi countries can

  1. Effect of Cold Water Immersion on Metabolic Rate in Humans

    Directory of Open Access Journals (Sweden)

    Austin Greenwood

    2017-04-01

    Full Text Available Background: Cold water immersion is a widely used form of cryotherapy in the active population despite the limited knowledge on its physiological effects. From an injury standpoint, reducing metabolic rate is advantageous to prevent secondary injury. In contrast, increased metabolism can be beneficial in ridding the body of unwanted metabolites. This study looked to determine the effect of cold water immersion on metabolic rate.  Understanding this phenomenon will help determine appropriate clinical applications of cold water immersion and lead to a better understanding of cryotherapy in general. This study looked to determine the effect of cryotherapy in the form of waist deep cold water immersion at 9° C on metabolic rate. Methods: 10 participants from a university student population volunteered and completed a 15-minute treatment of waist deep cold water (9° C immersion. Metabolic rate measurements were taken using a Jaeger Oxycon Mobile Unit for 5 minutes prior to treatment, 15 minutes of treatment, and 5 minutes post treatment for a total of 25 minutes. Statistical analysis was completed using a one way repeated measures ANOVA test to compare treatment intervals to baseline intervals. Results: Cold water immersion resulted in elevated metabolic rates for 8 of 10 participants during the first 5 minutes of treatment and for 6 of 10 in the 5 minute post treatment (p < 0.05. A second statistical analysis excluding the first 30 second data point in the 5-10 and 20-25 minute treatments was used to account for movement in and out of the whirlpool. The second analysis showed the same results as the first with the exception of one participant who no longer displayed a statistically significant change in the 20-25 minute interval. Conclusion: These results indicate that cold water immersion should not be used as a measure of reducing secondary injury because of its potential to increase metabolic rate, but instead may have potential benefits in

  2. Sodium testing of intermediate-size inducer pump in SPTF at ETEC

    Energy Technology Data Exchange (ETDEWEB)

    Pfouts, J.O.

    1979-03-24

    The overall test program includes pump assembly, installation, testing, removal from the test loop, disassembly and final inspection of the entire pump. Testing will include checkout tests, head/flow and efficiency characterizations at selected speeds and sodium temperatures, suction performance determination, a 2000 hour design point endurance test, a 300 hour off design endurance test, and thermal transient tests. The pump will be cleaned of sodium, disassembled, and examined before the 2000 hour endurance test and after the thermal transient tests to determine the effects that long-term operation at 200 percent NPSH margin and off design operation at the same flow and NPSH have on the pump components.

  3. Sodium testing of intermediate-size inducer pump in SPTF at ETEC

    Energy Technology Data Exchange (ETDEWEB)

    Pfouts, J.O.

    1978-08-04

    The overall test program includes pump assembly, installation, testing, removal from the test loop, disassembly and final inspection of the entire pump. Testing will include checkout tests, head/flow and efficiency characterizations at selected speeds and sodium temperatures, suction performance determination, a 2000 hour design point endurance test, a 300 hour off design endurance test, and thermal transient tests. The pump will be cleaned of sodium, disassembled, and examined before the 2000 hour endurance test and after the thermal transient tests to determine the effects that long-term operation at 200 percent NPSH margin and off design operation at the same flow and NPSH have on the pump components.

  4. Production and detection of cold antihydrogen atoms

    CERN Multimedia

    Amoretti, M; Bonomi, G; Bouchta, A; Bowe, P; Carraro, C; Cesar, C L; Charlton, M; Collier, M; Doser, Michael; Filippini, V; Fine, K S; Fontana, A; Fujiwara, M C; Funakoshi, R; Genova, P; Hangst, J S; Hayano, R S; Holzscheiter, M H; Jørgensen, L V; Lagomarsino, V; Landua, Rolf; Landua, Rolf; Lindelöf, D; Lodi-Rizzini, E; Macri, M; Madsen, N; Manuzio, G; Marchesotti, M; Montagna, P; Pruys, H S; Regenfus, C; Riedler, P; Rochet, J; Rotondi, A; Rouleau, G; Testera, G; Van der Werf, D P; Variola, A; Watson, T L; CERN. Geneva

    2002-01-01

    A theoretical underpinning of the standard model of fundamental particles and interactions is CPT invariance, which requires that the laws of physics be invariant under the combined discrete operations of charge conjugation, parity and time reversal. Antimatter, the existence of which was predicted by Dirac, can be used to test the CPT theorem experimental investigations involving comparisons of particles with antiparticles are numerous. Cold atoms and anti-atoms, such as hydrogen and anti-hydrogen, could form the basis of a new precise test, as CPT invariance implies that they must have the same spectrum. Observations of antihydrogen in small quantities and at high energies have been reported at the European Organization for Nuclear Research (CERN) and at Fermilab, but were not suited to precision comparison measurements. Here we demonstrate the production of antihydrogen atoms at very low energy by mixing trapped antiprotons and positrons in a cryogenic environment. The neutral anti-atoms have been detected...

  5. Cold paresis in multifocal motor neuropathy

    OpenAIRE

    Straver, Dirk C. G.; van Asseldonk, Jan-Thies H.; Notermans, Nicolette C.; Wokke, John H. J.; van den Berg, Leonard H.; Franssen, Hessel

    2010-01-01

    Increased weakness during cold (cold paresis) was reported in single cases of multifocal motor neuropathy (MMN). This was unexpected because demyelination is a feature of MMN and symptoms of demyelination improve, rather than worsen, in cold. It was hypothesized that cold paresis in MMN does not reflect demyelination only, but may indicate the existence of inflammatory nerve lesions with permanently depolarized axons that only just conduct at normal temperature, but fail at lower temperatures...

  6. Cold Vacuum Drying (CVD) Facility Technical Safety Requirements

    Energy Technology Data Exchange (ETDEWEB)

    KRAHN, D.E.

    2000-08-08

    The Technical Safety Requirements (TSRs) for the Cold Vacuum Drying Facility define acceptable conditions, safe boundaries, bases thereof, and management or administrative controls required to ensure safe operation during receipt of multi-canister overpacks (MCOs) containing spent nuclear fuel. removal of free water from the MCOs using the cold vacuum drying process, and inerting and testing of the MCOs before transport to the Canister Storage Building. Controls required for public safety, significant defense in depth, significant worker safety, and for maintaining radiological and toxicological consequences below risk evaluation guidelines are included.

  7. Critical Speed Measurements in the Tevatron Cold Compressors

    Science.gov (United States)

    DeGraff, B.; Bossert, R.; Martinez, A.; Soyars, W. M.

    2006-04-01

    The Fermilab Tevatron cryogenic system utilizes high-speed centrifugal cold compressors, manufactured by Ishikawajima-Harima Heavy Industries Co. Ltd. (IHI), for high energy operations. Nominal operating range for these compressors is 43,000 to 85,000 rpm. Past foil bearing failures prompted investigation to determine if critical speeds for operating compressors fall within operating range. Data acquisition hardware and software settings will be discussed for measuring liftoff, first critical and second critical speeds. Several tests provided comparisons between an optical displacement probe and accelerometer measurements. Vibration data and analysis of the 20 Tevatron ring cold compressors will be presented.

  8. Cryosphere and Psychrophiles: Insights into a Cold Origin of Life?

    Science.gov (United States)

    Feller, Georges

    2017-06-11

    Psychrophiles thrive permanently in the various cold environments on Earth. Their unsuspected ability to remain metabolically active in the most extreme low temperature conditions provides insights into a possible cold step in the origin of life. More specifically, metabolically active psychrophilic bacteria have been observed at -20 °C in the ice eutectic phase (i.e., the liquid veins between sea ice crystals). In the context of the RNA world hypothesis, this ice eutectic phase would have provided stability to the RNA molecules and confinement of the molecules in order to react and replicate. This aspect has been convincingly tested by laboratory experiments.

  9. Zinc for the common cold.

    Science.gov (United States)

    Singh, Meenu; Das, Rashmi R

    2013-06-18

    The common cold is one of the most widespread illnesses and is a leading cause of visits to the doctor and absenteeism from school and work. Trials conducted in high-income countries since 1984 investigating the role of zinc for the common cold symptoms have had mixed results. Inadequate treatment masking and reduced bioavailability of zinc from some formulations have been cited as influencing results. To assess whether zinc (irrespective of the zinc salt or formulation used) is efficacious in reducing the incidence, severity and duration of common cold symptoms. In addition, we aimed to identify potential sources of heterogeneity in results obtained and to assess their clinical significance. In this updated review, we searched CENTRAL (2012, Issue 12), MEDLINE (1966 to January week 2, 2013), EMBASE (1974 to January 2013), CINAHL (1981 to January 2013), Web of Science (1985 to January 2013), LILACS (1982 to January 2013), WHO ICTRP and clinicaltrials.gov. Randomised, double-blind, placebo-controlled trials using zinc for at least five consecutive days to treat, or for at least five months to prevent the common cold. Two review authors independently extracted data and assessed trial quality. Five trials were identified in the updated searches in January 2013 and two of them did not meet our inclusion criteria. We included 16 therapeutic trials (1387 participants) and two preventive trials (394 participants). Intake of zinc was associated with a significant reduction in the duration (days) (mean difference (MD) -1.03, 95% confidence interval (CI) -1.72 to -0.34) (P = 0.003) (I(2) statistic = 89%) but not the severity of common cold symptoms (MD -1.06, 95% CI -2.36 to 0.23) (P = 0.11) (I(2) statistic = 84%). The proportion of participants who were symptomatic after seven days of treatment was significantly smaller (odds ratio (OR) 0.45, 95% CI 0.20 to 1.00) (P = 0.05) than those in the control, (I(2 )statistic = 75%). The incidence rate ratio (IRR) of developing a

  10. Development of phytosanitary cold treatments for oranges infested with Bactrocera invadens and Bactrocera zonata (Diptera: Tephritidae) by comparison with existing cold treatment schedules for Ceratitis capitata (Diptera: Tephritidae).

    Science.gov (United States)

    Hallman, Guy J; Myers, Scott W; El-Wakkad, Mokhtar F; Tadrous, Meshil D; Jessup, Andrew J

    2013-08-01

    Phytosanitary cold treatments were tested for Bactrocera invadens Drew, Tsuruta, and White and Bactrocera zonata (Saunders) using comparisons with Ceratitis capitata (Wiedemann). Oranges were infested by puncturing holes in the peel and allowing tephritids to oviposit in the holes. The treatments were initiated when the larvae reached late third instar because previous research had shown that stage to be the most cold tolerant for all three species. Results show that B. invadens is not more cold tolerant than C. capitata and B. zonata at 1.0 +/- 0.1 degrees C and lend support to the use of C. capitata cold treatment schedules for B. invadens. It cannot be concluded that B. zonata is not more cold tolerant than C. capitata.

  11. Seedling phenology and cold hardiness: Moving targets

    Science.gov (United States)

    Diane L. Haase

    2011-01-01

    Phenology is the annual cycle of plant development as influenced by seasonal variations. Dormancy and cold hardiness are two aspects of the annual cycle. In temperate plants, the development of cold hardiness results in the ability to withstand subfreezing winter temperatures. Cold hardiness is also a reflection of overall stress resistance. In addition to describing...

  12. Finger cold-induced vasodilation : a review

    NARCIS (Netherlands)

    Daanen, H.A.M.

    2003-01-01

    Cold-induced vasodilation (CIVD) in the finger tips generally occurs 5-10 min after the start of local cold exposure of the extremities. This phenomenon is believed to reduce the risk of local cold injuries. However, CIVD is almost absent during hypothermia, when survival of the organism takes

  13. Frequent extreme cold exposure and brown fat and cold-induced thermogenesis: a study in a monozygotic twin.

    Directory of Open Access Journals (Sweden)

    Maarten J Vosselman

    Full Text Available INTRODUCTION: Mild cold acclimation is known to increase brown adipose tissue (BAT activity and cold-induced thermogenesis (CIT in humans. We here tested the effect of a lifestyle with frequent exposure to extreme cold on BAT and CIT in a Dutch man known as 'the Iceman', who has multiple world records in withstanding extreme cold challenges. Furthermore, his monozygotic twin brother who has a 'normal' sedentary lifestyle without extreme cold exposures was measured. METHODS: The Iceman (subject A and his brother (subject B were studied during mild cold (13°C and thermoneutral conditions (31°C. Measurements included BAT activity and respiratory muscle activity by [18F]FDG-PET/CT imaging and energy expenditure through indirect calorimetry. In addition, body temperatures, cardiovascular parameters, skin perfusion, and thermal sensation and comfort were measured. Finally, we determined polymorphisms for uncoupling protein-1 and β3-adrenergic receptor. RESULTS: Subjects had comparable BAT activity (A: 1144 SUVtotal and B: 1325 SUVtotal, within the range previously observed in young adult men. They were genotyped with the polymorphism for uncoupling protein-1 (G/G. CIT was relatively high (A: 40.1% and B: 41.9%, but unlike during our previous cold exposure tests in young adult men, here both subjects practiced a g-Tummo like breathing technique, which involves vigorous respiratory muscle activity. This was confirmed by high [18F]FDG-uptake in respiratory muscle. CONCLUSION: No significant differences were found between the two subjects, indicating that a lifestyle with frequent exposures to extreme cold does not seem to affect BAT activity and CIT. In both subjects, BAT was not higher compared to earlier observations, whereas CIT was very high, suggesting that g-Tummo like breathing during cold exposure may cause additional heat production by vigorous isometric respiratory muscle contraction. The results must be interpreted with caution given the

  14. Rheological properties of cold recycled mixtures

    Directory of Open Access Journals (Sweden)

    Ján Gillinger

    2007-04-01

    Full Text Available The paper presents some of the results of research focused on cold recycled mixtures properties. Within the study, eight mixtures with a different amount of reclaimed asphalt, bitumen emulsion and cement were evaluated. The results of static creep, complex modulus and fatigue conducted on trapezoidal specimens are discussed in the paper. The static creep modulus and the complex modulus were investigated at temperatures 27 ºC, 11 ºC and 0 ºC. These temperatures represent temperatures of asphalt layer with a thickness in the range from 20 to 25 cm for summer, spring/ autumn and winter in Slovakia. In addition fatigue was investigated at the temperature of 27 ºC. It was found that the binder combination plays an important role in rheological performance of cold recycled mixtures. However, at different contents of reclaimed asphalt, the effect of bitumen emulsion was different. This can be observable particularly when analyzing the results of the fatigue test. The mixtures with a higher amount of cement were better in terms of the fatigue life. The investigated mixtures in general were little sensitive to the change of loading frequency which simulates the traffic speed.

  15. The barrel EM is cold and full

    CERN Multimedia

    Fournier, D

    After insertion of the two EM wheels in the cryostat in 2003, the cold vessel was finally closed in December (Omega seals and welds). This was then followed by the installation of the solenoid in February, and the closing of the warm vessel in March (see eNews of December 2003). During these few months the LAr cryogenic system was thoroughly tested, and its control system commissioned, each of the ~1000 control points at a time. Finally, in April the cool-down could start. Rather unusual for liquid argon detectors, the cool-down was made in its first part (above 140K) by circulating cold nitrogen gas (instead of liquid nitrogen) in the heat exchangers. The reason was to limit as much as possible temperature gradients in the calorimeter body. With the accordion structure, each of the EM wheel behaves as a single piece, which could be damaged if the supporting rings at its outside would contract faster than the active part inside. Also with improperly controlled gradients, the two wheels - 4 meters in diamete...

  16. Cold pressor pain in skin picking disorder.

    Science.gov (United States)

    Grant, Jon E; Redden, Sarah A; Chamberlain, Samuel R

    2017-03-01

    Excoriation (skin-picking) disorder (SPD) is a disabling, under-recognized condition in which individuals repeatedly pick at their skin, leading to noticeable tissue damage. There has been no examination as to whether individuals with SPD have different pain thresholds or pain tolerances compared to healthy counterparts. Adults with SPD were examined on a variety of clinical measures including symptom severity and functioning. All participants underwent the cold pressor test. Heart rate, blood pressure, and self-reported pain were compared between SPD participants (n=14) and healthy controls (n=14). Adults with SPD demonstrated significantly dampened autonomic response to cold pressor pain as exhibited by reduced heart rate compared to controls (group x time interaction using repeated ANOVA F=3.258, p<0.001). There were no significant differences between the groups in terms of overall pain tolerance (measured in seconds), recovery time, or blood pressure. SPD symptom severity was not significantly associated with autonomic response in the patients. In this study, adults with SPD exhibited a dampened autonomic response to pain while reporting pain intensity similar to that reported by the controls. The lack of an autonomic response may explain why the SPD participants continue a behavior that they cognitively find painful and may offer options for future interventions. Copyright © 2017 Elsevier Ireland Ltd. All rights reserved.

  17. COLDDIAG: A Cold Vacuum Chamber for Diagnostics

    CERN Document Server

    Casalbuoni, S; Gerstl, S; Grau, A W; Hagelstein, M; Saez de Jauregui, D; Boffo, C; Sikler, G; Baglin, V; Cox, M P; Schouten, J C; Cimino, R; Commisso, M; Spataro, B; Mostacci, A; Wallen, E J; Weigel, R; Clarke, J; Scott, D; Bradshaw, T; Jones, R; Shinton, I

    2011-01-01

    One of the still open issues for the development of superconducting insertion devices is the understanding of the beam heat load. With the aim of measuring the beam heat load to a cold bore and the hope to gain a deeper understanding in the beam heat load mechanisms, a cold vacuum chamber for diagnostics is under construction. The following diagnostics will be implemented: i) retarding field analyzers to measure the electron energy and flux, ii) temperature sensors to measure the total heat load, iii) pressure gauges, iv) and mass spectrometers to measure the gas content. The inner vacuum chamber will be removable in order to test different geometries and materials. This will allow the installation of the cryostat in different synchrotron light sources. COLDDIAG will be built to fit in a short straight section at ANKA. A first installation at the synchrotron light source Diamond is foreseen in June 2011. Here we describe the technical design report of this device and the planned measurements with beam.

  18. Changes in cold-induced vasodilation during Arctic exercises.

    Science.gov (United States)

    Livingstone, S D

    1976-03-01

    The effect of exposure to cold on cold-induced vasodilation (CIVD) was examined in military personnel who had experienced a 2-wk stay in the Artic. During this time, the daily regimen consisted of long marches over difficult terrain and sleep in unheated tents with diurnal temperatures ranging from -10 to -40 degrees C. In tests conducted before and after the 2-wk period, CIVD was measured in the left middle finger of each subject by its immersion in ice water. After the 2-wk period, the value of mean finger temperature during the test had decreased relative to that observed before the test, the time required before the first vasodilative temperature increase occurred had become greater, and the finger temperature value at which the vasodilative increase was initiated has been lowered. These changes manifest a deleterious effect of cold exposure on the CIVD, contrary to expectations, and suggest that the effect of short-term cold exposure is to produce a general rather than peripheral acclimation in these subjects.

  19. Cosmicflows-3: Cold Spot Repeller?

    Science.gov (United States)

    Courtois, Hélène M.; Tully, R. Brent; Hoffman, Yehuda; Pomarède, Daniel; Graziani, Romain; Dupuy, Alexandra

    2017-09-01

    The three-dimensional gravitational velocity field within z ˜ 0.1 has been modeled with the Wiener filter methodology applied to the Cosmicflows-3 compilation of galaxy distances. The dominant features are a basin of attraction and two basins of repulsion. The major basin of attraction is an extension of the Shapley concentration of galaxies. One basin of repulsion, the Dipole Repeller, is located near the anti-apex of the cosmic microwave background dipole. The other basin of repulsion is in the proximate direction toward the “Cold Spot” irregularity in the cosmic microwave background. It has been speculated that a vast void might contribute to the amplitude of the Cold Spot from the integrated Sachs-Wolfe effect.

  20. Cosmicflows-3: Cold Spot Repeller?

    Energy Technology Data Exchange (ETDEWEB)

    Courtois, Hélène M.; Graziani, Romain; Dupuy, Alexandra [University of Lyon, UCB Lyon 1, CNRS/IN2P3, IPN, Lyon (France); Tully, R. Brent [Institute for Astronomy, University of Hawaii, 2680 Woodlawn Drive, Honolulu, HI 96822 (United States); Hoffman, Yehuda [Racah Institute of Physics, Hebrew University, Jerusalem, 91904 (Israel); Pomarède, Daniel [Institut de Recherche sur les Lois Fondamentales de l’Univers, CEA, Université Paris-Saclay, F-91191 Gif-sur-Yvette (France)

    2017-09-20

    The three-dimensional gravitational velocity field within z ∼ 0.1 has been modeled with the Wiener filter methodology applied to the Cosmicflows-3 compilation of galaxy distances. The dominant features are a basin of attraction and two basins of repulsion. The major basin of attraction is an extension of the Shapley concentration of galaxies. One basin of repulsion, the Dipole Repeller, is located near the anti-apex of the cosmic microwave background dipole. The other basin of repulsion is in the proximate direction toward the “Cold Spot” irregularity in the cosmic microwave background. It has been speculated that a vast void might contribute to the amplitude of the Cold Spot from the integrated Sachs–Wolfe effect.

  1. Cold dark matter heats up.

    Science.gov (United States)

    Pontzen, Andrew; Governato, Fabio

    2014-02-13

    A principal discovery in modern cosmology is that standard model particles comprise only 5 per cent of the mass-energy budget of the Universe. In the ΛCDM paradigm, the remaining 95 per cent consists of dark energy (Λ) and cold dark matter. ΛCDM is being challenged by its apparent inability to explain the low-density 'cores' of dark matter measured at the centre of galaxies, where centrally concentrated high-density 'cusps' were predicted. But before drawing conclusions, it is necessary to include the effect of gas and stars, historically seen as passive components of galaxies. We now understand that these can inject heat energy into the cold dark matter through a coupling based on rapid gravitational potential fluctuations, explaining the observed low central densities.

  2. [Cold urticaria: case series and literature review].

    Science.gov (United States)

    Sánchez, Jorge Mario; Ramírez, Ruth Helena; Tamayo, Liliana María; Chinchilla, Carlos Fernando; Cardona, Ricardo

    2011-06-01

    Cold urticaria is one of the five most common causes of chronic urticaria and is grouped as a physical urticaria. It can occur after exposure to cold, either through solid objects, air or liquids. Patients may have symptoms of urticaria, angioedema, respiratory distress and even anaphylaxis when the skin is exposed to a cold environment, such as handling refrigerated objects, swimming in cold water or entering an air-conditioned room. Five cases of cold urticaria are presented, followed by a brief literature review.

  3. Window Performance in Extreme Cold,

    Science.gov (United States)

    1982-12-01

    Casement windows-windows with sashes hinged on ATID difference between the indoor ambient and the side. indoor dewpoint temperatures ATIo difference...did. Installed casement windows (at 0.23 ft 3/ PREVIOUS WORK IN COLD min ft) were the only type of window with airtight- WEATHER WINDOW PERFORMANCE...to calculate air leakage hung sash unit to a casement or possibly adding another with no wind and with double the mean wind as latch to the casement

  4. Nonfreezing Cold-Induced Injuries

    Science.gov (United States)

    2011-01-01

    3Department of Occupational Medicine, Trenchard Lines, Upavon, Pewsey, Wilts; 4Thermal and Mountain Medicine Division, United States Army Research Institute...no clear ICD-9 (International Statistical Classification of Disease ) code for NFCI, and most reported figures are not actually prevalence but...sweating even in cold weather [27] and the hyperhidrosis increases the risk of fungal infections [29]. In the most severe cases gangrene can develop

  5. Small Cold Temperature Instrument Packages

    Science.gov (United States)

    Clark, P. E.; Millar, P. S.; Yeh, P. S.; Feng, S.; Brigham, D.; Beaman, B.

    We are developing a small cold temperature instrument package concept that integrates a cold temperature power system with ultra low temperature ultra low power electronics components and power supplies now under development into a 'cold temperature surface operational' version of a planetary surface instrument package. We are already in the process of developing a lower power lower temperature version for an instrument of mutual interest to SMD and ESMD to support the search for volatiles (the mass spectrometer VAPoR, Volatile Analysis by Pyrolysis of Regolith) both as a stand alone instrument and as part of an environmental monitoring package. We build on our previous work to develop strategies for incorporating Ultra Low Temperature/Ultra Low Power (ULT/ULP) electronics, lower voltage power supplies, as well as innovative thermal design concepts for instrument packages. Cryotesting has indicated that our small Si RHBD CMOS chips can deliver >80% of room temperature performance at 40K (nominal minimum lunar surface temperature). We leverage collaborations, past and current, with the JPL battery development program to increase power system efficiency in extreme environments. We harness advances in MOSFET technology that provide lower voltage thresholds for power switching circuits incorporated into our low voltage power supply concept. Conventional power conversion has a lower efficiency. Our low power circuit concept based on 'synchronous rectification' could produce stable voltages as low as 0.6 V with 85% efficiency. Our distributed micro-battery-based power supply concept incorporates cold temperature power supplies operating with a 4 V or 8 V battery. This work will allow us to provide guidelines for applying the low temperature, low power system approaches generically to the widest range of surface instruments.

  6. Using an Emergency Department Syndromic Surveillance System to investigate the impact of extreme cold weather events.

    Science.gov (United States)

    Hughes, H E; Morbey, R; Hughes, T C; Locker, T E; Shannon, T; Carmichael, C; Murray, V; Ibbotson, S; Catchpole, M; McCloskey, B; Smith, G; Elliot, A J

    2014-07-01

    This report describes the development of novel syndromic cold weather public health surveillance indicators for use in monitoring the impact of extreme cold weather on attendances at EDs, using data from the 2010-11 and 2011-12 winters. A number of new surveillance indicators were created specifically for the identification and monitoring of cold weather related ED attendances, using the diagnosis codes provided for each attendance in the Emergency Department Syndromic Surveillance System (EDSSS), the first national syndromic surveillance system of its kind in the UK. Using daily weather data for the local area, a time series analysis to test the sensitivity of each indicator to cold weather was undertaken. Diagnosis codes relating to a health outcome with a potential direct link to cold weather were identified and assigned to a number of 'cold weather surveillance indicators'. The time series analyses indicated strong correlations between low temperatures and cold indicators in nearly every case. The strongest fit with temperature was cold related fractures in females, and that of snowfall was cold related fractures in both sexes. Though currently limited to a small number of sentinel EDs, the EDSSS has the ability to give near real-time detail on the magnitude of the impact of weather events. EDSSS cold weather surveillance fits well with the aims of the Cold Weather Plan for England, providing information on those particularly vulnerable to cold related health outcomes severe enough to require emergency care. This timely information aids those responding to and managing the effects on human health, both within the EDs themselves and in the community as a whole. Crown Copyright © 2014. Published by Elsevier Ltd. All rights reserved.

  7. Friction Modelling In Connection With Cold Forming Processes

    DEFF Research Database (Denmark)

    Tan, Xincai

    in the FEM analyses of the process tests. In the simulative testing, the compression-twist tests in open die and closed die are carried out to measure friction stress directly at varying normal pressure, surface expansion, sliding length and tool temperature etc. It is found that normal pressure...... and lubrication significantly influence friction stress. Although other parameters, like surface expansion, also affect friction, their influence is less significant. Comparison of theoretical and experimental analysis of the tests with friction sensitive flow and the three friction models, show appreciable......This thesis describes theoretical as well as experimental studies of friction in cold forming processes. In cold forming, a main obstacle impeding accurate prediction in numerical modelling is the lack of knowledge with regard to the friction conditions at the tool/workpiece interface. Friction has...

  8. Mod-2 wind turbine project assessment and cluster test plans

    Science.gov (United States)

    Gordon, L. H.

    1982-01-01

    An assessment of the Mod-2 Wind Turbine project is presented based on initial goals and present results. Specifically, the Mod-2 background, project flow, and a chronology of events/results leading to Mod-2 acceptance is presented. After checkout/acceptance of the three operating turbines, NASA/LeRC will continue management of a two year test program performed at the DOE Goodnoe Hills test site. This test program is expected to yield data necessary for the continued development and optimization of wind energy systems. These test activities, the implementation of, and the results to date are also presented.

  9. Cold agglutinin activity in 2 dogs.

    Science.gov (United States)

    Rojas-Temahuay, Gabriela; Crain, Sarah; Benson, Catherine; Sharkey, Leslie; Nothnagel, Geneva

    2014-09-01

    A 5-year-old neutered male Mastiff and an 8-year-old spayed female Labrador Retriever were presented to the University of Minnesota Veterinary Medical Center. The Mastiff was presented for evaluation of lameness and pyoderma one month prior in Missouri, where he tested positive for Ehrlichia canis by serum ELISA test, treated with doxycycline. PCR for Ehrlichia sp, Anaplasma sp, Babesia sp, and Bartonella sp, and PCR for antigen receptor rearrangement were negative, serum protein electrophoresis (SPE) revealed polyclonal gammopathy, and mildly reactive lymphoid cells were seen cytologically. The Labrador presented with a proliferative rostral mandibular gingival mass and lipomas for further presurgical evaluation of cold agglutinin activity documented by a commercial laboratory 2 years earlier prior to removal of a grade II mast cell tumor. This dog had a negative SNAP4Dx, normal SPE, and persistently increased serum ALP activity and polyuria/polydipsia suggestive for hyperadrenocorticism. Both dogs had markedly agglutinated RBC in the EDTA samples that dispersed with warming, and normal plasma color. Cold agglutinin activity was demonstrated by direct saline agglutination testing using whole blood and washed erythrocytes demonstrating agglutination at 30°C, 25°C, 15°C, and 4°C, but not at 37°C. CBC results (ADVIA 2120i) from the Mastiff revealed no significant differences in the RBC results obtained at room temperature (RT) and at 37°C; however, the RT run demonstrated negative bias in neutrophil and platelet concentrations attributed to rapid RBC settling. This uncommon hematologic condition may cause artifacts on the automated leukogram and platelet count, and may be subclinical for long periods. © 2014 American Society for Veterinary Clinical Pathology and European Society for Veterinary Clinical Pathology.

  10. Susceptibility to hypoxia and breathing control changes after short-term cold exposures

    Directory of Open Access Journals (Sweden)

    Lyudmila T. Kovtun

    2013-08-01

    Full Text Available Background . Hypoxia is the reduction of oxygen availability due to external or internal causes. There is large individual variability of response to hypoxia. Objective . The aim of this study was to define individual and typological features in susceptibility to hypoxia, its interrelation with hypoxic and hypercapnic ventilatory responses (HVR and HCVR, respectively and their changes after cold acclimation. Design . Twenty-four healthy men were tested. HVR and HCVR were measured by the rebreathing method during hypoxic and hypercapnic tests, respectively. These tests were carried out in thermoneutral conditions before and after cold exposures (nude, at 13°C, 2 h daily, for 10 days. Susceptibility to hypoxia (sSaO2 was determined as haemoglobin saturation slope during hypoxic test. Results . It was found that HVR and HCVR significantly increased and susceptibility to hypoxia (sSaO2 tended to decrease after cold acclimation. According to sSaO2 results before cold exposures, the group was divided into 3: Group 1 – with high susceptibility to hypoxia, Group 2 – medium and Group 3 – low susceptibility. Analysis of variances (MANOVA shows the key role of susceptibility to hypoxia and cold exposures and their interrelation. Posterior analysis (Fisher LSD showed significant difference in susceptibility to hypoxia between the groups prior to cold acclimation, while HVR and HCVR did not differ between the groups. After cold acclimation, susceptibility to hypoxia was not significantly different between the groups, while HCVR significantly increased in Groups 1 and 3, HVR significantly increased in Group 3 and HCVR, HVR did not change in Group 2. Conclusions . Short-term cold exposures caused an increase in functional reserves and improved oxygen supply of tissues in Group 1. Cold exposure hypoxia has caused energy loss in Group 3. Group 2 showed the most appropriate energy conservation reaction mode to cold exposures. No relation was found between

  11. Susceptibility to hypoxia and breathing control changes after short-term cold exposures.

    Science.gov (United States)

    Kovtun, Lyudmila T; Voevoda, Mikhail I

    2013-01-01

    Hypoxia is the reduction of oxygen availability due to external or internal causes. There is large individual variability of response to hypoxia. The aim of this study was to define individual and typological features in susceptibility to hypoxia, its interrelation with hypoxic and hypercapnic ventilatory responses (HVR and HCVR, respectively) and their changes after cold acclimation. Twenty-four healthy men were tested. HVR and HCVR were measured by the rebreathing method during hypoxic and hypercapnic tests, respectively. These tests were carried out in thermoneutral conditions before and after cold exposures (nude, at 13°C, 2 h daily, for 10 days). Susceptibility to hypoxia (sSaO2) was determined as haemoglobin saturation slope during hypoxic test. It was found that HVR and HCVR significantly increased and susceptibility to hypoxia (sSaO2) tended to decrease after cold acclimation. According to sSaO2 results before cold exposures, the group was divided into 3: Group 1--with high susceptibility to hypoxia, Group 2--medium and Group 3--low susceptibility. Analysis of variances (MANOVA) shows the key role of susceptibility to hypoxia and cold exposures and their interrelation. Posterior analysis (Fisher LSD) showed significant difference in susceptibility to hypoxia between the groups prior to cold acclimation, while HVR and HCVR did not differ between the groups. After cold acclimation, susceptibility to hypoxia was not significantly different between the groups, while HCVR significantly increased in Groups 1 and 3, HVR significantly increased in Group 3 and HCVR, HVR did not change in Group 2. Short-term cold exposures caused an increase in functional reserves and improved oxygen supply of tissues in Group 1. Cold exposure hypoxia has caused energy loss in Group 3. Group 2 showed the most appropriate energy conservation reaction mode to cold exposures. No relation was found between the thermoregulation and the susceptibility to hypoxia.

  12. ATHENA : First Production of Cold Antihydrogen and Beyond

    CERN Document Server

    Kellerbauer, A G; Amsler, Claude; Bonomi, G; Bowe, P; Canali, C; Carraro, C; Cesar, C L; Charlton, M; Doser, Michael; Fontanta A; Fujiwara, M C; Funakoshi, R; Genova, P; Hangst, J S; Hayano, R S; Johnson, I; Jurgensen, L V; Lagomarsino, V; Landua, Rolf; Loririzzini, E; Macr, M; Madsen, N; Manuzio, G; Mitchard, D; Montagna, P; Pruys, H S; Regenfus, C; Rotondi, A; Testera, G; Vatiola, A; Venturelli, L; Van der Werf, D P; Yamazaki, Y; Zurlo, A

    2004-01-01

    Atomic systems of antiparticles are the laboratories of choice for tests of CPT symmetry with antimatter. The ATHENA experiment was the first to report the production of copious amounts of cold antihydrogen in 2002. This article reviews some of the insights that have since been gained concerning the antihydrogen production process as well as the external and internal properties of the produced anti-atoms. Furthermore, the implications of those results on future prospects of symmetry tests with antimatter are discussed.

  13. Treatment of the common cold.

    Science.gov (United States)

    Supiyaphun, Pakpoom; Kerekhanjananarong, Virachai; Saengpanich, Supinda; Cutchavaree, Amnuay

    2003-06-01

    Common colds are usually treated by the patients themselves with over-the-counter (OTC) cold medications. Many cough and cold remedies are available and sold freely without prescription. The authors conducted a study to compare the efficacy, adverse effects, the quality of life (QOL) and the patient's opinion and appreciation on the drugs (POD) between Dayquil/Nyquil and Actifed DM plus paracetamol syrup. In this prospective, investigator-blinded clinical trial, 120 patients, aged between 15 and 60 years old, with common colds within 72 hours, who accepted the trial and gave informed written consent, were randomized into two treatment groups. One patient was excluded due to evidence of bacterial infection. Fifty-nine patients were treated with Dayquil/Nyquil (D/N group), while the other 60 patients had Actifed DM plus paracetamol (ADM/P group) for three days. On day 1 the patient's demographic data (sex, age, body weight, blood pressure, co-existing diseases/conditions, drug use, and allergy to any drugs), the most prominent symptoms and its duration were recorded. All patients were screened for bacterial infection by physical examination, complete blood count and sinus radiographs. The symptoms (nasal obstruction, rhinorrhea, sneezing, cough, sore throat, fever and headache) and signs (injected nasal mucosa, nasal discharge and pharyngeal discharge) were scored, based on 4-point scale (0 to 3), on days 1 and 4. Changing of the symptoms and QOL were recorded on the diary card. The patient's opinion and appreciation on the drugs (POD) was assessed on day 4. The effectiveness (the ability to lessen the symptoms and signs), QOL and POD between two treatments were compared. The demographic data between the two groups were similar. The four most common prominent symptoms of common colds in our series were cough (47.9%), sore throat (26.17%), rhinorrhea (8.4%) and headache (8.4%). However, both treatments were equally effective in lessening the symptoms (P = 0.426) and

  14. Numerical calculation of the main factors on cold cracking

    Energy Technology Data Exchange (ETDEWEB)

    Stadtaus, M.; Michailov, V.; Wohlfahrt, H. [Institut f. Schweisstechnik, TW Braunschweig, Langer Kamp 8, 38106 Braunschweig (Germany)

    2003-01-01

    Low alloy high-strength steels are nowadays very common in industrial application offering a number of favourable characteristics. However, cold cracking is an increasing problem concerning the weldability of these materials. For the prediction of cold cracking susceptibility many different tests exist. The most important ones are the Tekken-(Y-groove restraint test), the controlled-thermal-severity test (CTS) and the implant test. But in spite of the same or similar welding conditions, one gets different minimum preheat temperatures dependent on the used test procedure. Therefore, a better evaluation of these tests seems to be necessary. Based on the commercial FEA-tool SYSWELD three main factors influencing cold cracking were investigated for MAG-welded Tekken specimens: the distribution of microstructure, the stress-strain state and the hydrogen concentration. The analysis was performed for S690 low alloy high-strength steel. Also, welding experiments were carried out to determine temperature field and microstructure. (Abstract Copyright [2003], Wiley Periodicals, Inc.)

  15. ACTH (Adrenocorticotropic Hormone) Test

    Science.gov (United States)

    ... Factor Antibody Iron Iron Tests JAK2 Mutation Kidney Stone Analysis Kidney Stone Risk Panel KRAS Mutation Lactate Lactate Dehydrogenase (LD) ... Frequent nighttime urination Unexplained weight loss Hot flashes Cold sensitivity When the condition is due to a ...

  16. Dengue Fever Testing

    Science.gov (United States)

    ... Factor Antibody Iron Iron Tests JAK2 Mutation Kidney Stone Analysis Kidney Stone Risk Panel KRAS Mutation Lactate Lactate Dehydrogenase (LD) ... passing blood in the stool, difficulty breathing and cold clammy skin, especially in the extremities. During the ...

  17. Thyroid Diseases Tests

    Science.gov (United States)

    ... Factor Antibody Iron Iron Tests JAK2 Mutation Kidney Stone Analysis Kidney Stone Risk Panel KRAS Mutation Lactate Lactate Dehydrogenase (LD) ... functions; symptoms include weight gain, dry skin, constipation, cold intolerance, puffy skin, hair loss, fatigue, and menstrual ...

  18. The Cold man. A clinical case of the cold sensation.

    Directory of Open Access Journals (Sweden)

    Salvatore Settineri

    2013-09-01

    Full Text Available The lack of correlation between available knowledge and the current approach to Somatoform Disorders is highlighted.. Methods: the study, via the analysis of an unusual clinical case of an anomalous sensation of cold, examines various hypotheses on the physiopathology of somatization. Conclusions: a conceptualization would focus attention on the level of patients’ preoccupation with their symptoms, on the anomalies of the variations of perceptions and on patients’ hyperarousal. It could lead to a more harmonious position in psychiatry, between anthropologically-based understanding and interpretation of psychophysical information.

  19. Antimatter Matters: Progress in Cold Antihydrogen Research

    Science.gov (United States)

    Yamazaki, Yasunori

    2012-11-01

    The purpose of cold antihydrogen research is briefly reviewed together with the latest developments of manipulating antihydrogen atoms. Two major progresses last year were the trapping of antihydrogen atoms in a magnetic bottle and synthesis of antihydrogen atoms in a cusp trap, where a spin-polarized antihydrogen beam can be extracted as an intensified beam. The magnetic bottle consists of an octupole coil and a pair of mirror coils, which improved the magnetic field uniformity near the axis, and so the stability of trapping antiprotons and positrons. Eventually, antihydrogen atoms were trapped for more than 1000s, which is ready to be testified with high precision laser spectroscopy. The cusp trap consists of a superconducting anti-Helmholtz coil and a stack of multiple ring electrodes. This success opens a new path to make a stringent test of the CPT symmetry via high precision microwave spectroscopy of ground-state hyperfine transitions of antihydrogen atoms.

  20. Rutting Performance of Cold-Applied Asphalt Repair Materials for Airfield Pavements

    Science.gov (United States)

    2017-06-23

    15 3.2 APA rutting .................................................................................................................... 16 3.3...10 Figure 2.7. Typical tested APA specimen. .................................................................................................. 11...14 Figure 3.1. Cold mix 1-day APA

  1. Cognitive Performance during a 24-Hour Cold Exposure Survival Simulation

    Directory of Open Access Journals (Sweden)

    Michael J. Taber

    2016-01-01

    Full Text Available Survivor of a ship ground in polar regions may have to wait more than five days before being rescued. Therefore, the purpose of this study was to explore cognitive performance during prolonged cold exposure. Core temperature (Tc and cognitive test battery (CTB performance data were collected from eight participants during 24 hours of cold exposure (7.5°C ambient air temperature. Participants (recruited from those who have regular occupational exposure to cold were instructed that they could freely engage in minimal exercise that was perceived to maintaining a tolerable level of thermal comfort. Despite the active engagement, test conditions were sufficient to significantly decrease Tc after exposure and to eliminate the typical 0.5–1.0°C circadian rise and drop in core temperature throughout a 24 h cycle. Results showed minimal changes in CTB performance regardless of exposure time. Based on the results, it is recommended that survivors who are waiting for rescue should be encouraged to engage in mild physical activity, which could have the benefit of maintaining metabolic heat production, improve motivation, and act as a distractor from cold discomfort. This recommendation should be taken into consideration during future research and when considering guidelines for mandatory survival equipment regarding cognitive performance.

  2. Validation of cold chain during distribution of parenteral nutrition

    Directory of Open Access Journals (Sweden)

    Federico Tuan

    2015-09-01

    Full Text Available Objective: this study aims to demonstrate the suitability of the process used to condition the extemporaneous mixtures of parenteral nutrition for distribution, considering the objective of preserving the cold chain during transport until it reaches the patient, necessary to ensure stability, effectiveness and safety of these mixtures. Method: concurrent validation, design and implementation of a protocol for evaluating the process of packaging and distribution of MNPE developed by a pharmaceutical laboratory. Running tests, according to predefined acceptance criteria. It is performed twice, in summer and on routes that require longer transfer time. Evaluation of conservation of temperature by monitoring the internal temperature values of each type of packaging, recorded by data loggers calibrated equipment. Results: the different tests meet the established criteria. The collected data ensure the maintenance of the cold chain for longer than the transfer time to the most distant points. Conclusions: this study establishes the suitability of the processes to maintaining the cold chain for transfer from the laboratory to the patient pharmacist. Whereas the breaking of cold chain can cause changes of compatibility and stability of parenteral nutrition and failures nutritional support, this study contributes to patient safety, one of the relevant dimensions of quality of care the health.

  3. Performance Evaluation of Semiplastic Recycled Cold Asphalt Using Noncement Binders

    Directory of Open Access Journals (Sweden)

    Byung Jae Lee

    2015-01-01

    Full Text Available The optimal mixing conditions for semiplastic recycled cold asphalt, which recycled waste asphalt and used noncement binders (NCB, were assessed through verification of the performance. The NCB of 6% desulfurization gypsum mixing was found to have the most outstanding properties. For the Marshall stability, 4% (NCB filler mixing brought about a 1.92-time strength increase effect compared to OPC (2% and was improved when using modified asphalt and SBR. The flow test results showed that although an increase dosage of filler and SBR decreased the flow value of the semiplastic recycled cold asphalt, an increase dosage of asphalt emulsion improved the flow value. The indirect tensile strength and liquid immersion residual stability for the condition with greatest Marshall stability were most outstanding with 0.95 MPa and 83.6%, respectively. Evaluation of the recycled cold asphalt abrasion durability revealed that for the case of mixing more than 4% NCB the mass loss rate was lower than 20%. The abrasion durability was found to improve when using modified emulsified asphalt and SBR substitution. From the test results, it was found that the optimal mixing proportion of semiplastic recycled cold asphalt satisfied mechanical properties and durability is NCB with 4%, emulsified asphalt with 3%, and SBR substitution with 20%.

  4. Experimental Study of Axially Tension Cold Formed Steel Channel Members

    Science.gov (United States)

    Apriani, Widya; Lubis, Fadrizal; Angraini, Muthia

    2017-12-01

    Experimental testing is commonly used as one of the steps to determine the cause of the collapse of a building structure. The collapse of structures can be due to low quality materials. Although material samples have passed laboratory tests and the existing technical specifications have been met but there may be undetected defects and known material after failure. In this paper will be presented Experimental Testing of Axially Tension Cold Formed Steel Channel Members to determine the cause of the collapse of a building roof truss x in Pekanbaru. Test of tensile strength material cold formed channel sections was performed to obtain the main characteristics of Cold Formed steel material, namely ultimate tensile strength loads that can be held by members and the yield stress possessed by channel sections used in construction. Analysis of axially tension cold formed steel channel section presents in this paper was conducted through experimental study based on specificationsAnnualBook of ASTM Standards: Metal Test methods and Analitical Procedures, Section 3 (1991). The result of capacity loads experimental test was compared with design based on SNI 03-7971-2013standard of Indonesia for the design of cold formed steel structural members. The results of the yield stress of the material will be seen against the minimum allowable allowable stress range. After the test, the percentace of ultimate axial tension capacity theory has a result that is 16.46% larger than the ultimate axial tension capacity experimental. When compared with the load that must be borne 5.673 kN/m it can be concluded that 2 specimens do not meet. Yield stress of member has fulfilled requirement that wass bigger than 550 MPa. Based on the curve obtained ultimate axial tension capacity theory, results greater than experimental. The greatest voltage value (fu) is achieved under the same conditions as its yield stress. For this specimen with a melting voltage value fy = 571.5068 MPa has fulfilled the

  5. Cold weld cracking susceptibility of high strength low alloyed (HSLA steel NIONIKRAL 70

    Directory of Open Access Journals (Sweden)

    A. S. Tawengi

    2014-10-01

    Full Text Available In view of the importance of high strength low alloy (HSLA steels, particularly for critical applications such as offshore plat forms, pipeline and pressure vessels, this paper reports on an investigation of how to weld this type of steel without cold cracking. Using manual metal arc welding process and Tekken test (Y - Grove test has been carried out both to observe the cold cracking phenome non, and to investigate the influencing factors, such as preheating temperature and energy input, as well as electrode strength and diameter. How ever the results of the experiments show that there is a risk of cold cracking.

  6. WITHDRAWN: Antivirals for the common cold.

    Science.gov (United States)

    Jefferson, T O; Tyrrell, D

    2007-07-18

    The common cold is a ubiquitous short and usually mild illness for which preventive and treatment interventions have been under development since the mid-40s. As our understanding of the disease has increased, more experimental antivirals have been developed. This review attempts to draw together experimental evidence of the effects of these compounds. To identify, assemble, evaluate and (if possible) synthesise the results of published and unpublished randomised controlled trials of the effects of antivirals to prevent or minimise the impact of the common cold. We searched electronic databases, corresponded with researchers and handsearched the archives of the MRC's Common Cold Unit (CCU). We included original reports of randomised and quasi-randomised trials assessing the effects of antivirals on volunteers artificially infected and in individuals exposed to colds in the community. We included 241 studies assessing the effects of Interferons, interferon-inducers and other antivirals on experimental and naturally occurring common colds, contained in 230 reports. We structured our comparisons by experimental or community setting. Although intranasal interferons have high preventive efficacy against experimental colds (protective efficacy 46%, 37% to 54%) and to a lesser extent against natural colds (protective efficacy 24%, 21% to 27%) and are also significantly more effective than placebo in attenuating the course of experimental colds (WMD 15.90, 13.42 to 18.38), their safety profile makes compliance with their use difficult. For example, prolonged prevention of community colds with interferons causes blood-tinged nasal discharge (OR 4.52, 3.78 to 5.41). Dipyridamole (protective efficacy against natural colds 49%, 30% to 62%), ICI 130, 685 (protective efficacy against experimental colds 58%, 35% to 74% ), Impulsin (palmitate) (protective efficacy against natural colds 44%, CI 35% to 52% ) and Pleconaril (protective efficacy against experimental colds 71%, 15% to

  7. On the variability of cold region flooding

    Science.gov (United States)

    Matti, Bettina; Dahlke, Helen E.; Lyon, Steve W.

    2016-03-01

    Cold region hydrological systems exhibit complex interactions with both climate and the cryosphere. Improving knowledge on that complexity is essential to determine drivers of extreme events and to predict changes under altered climate conditions. This is particularly true for cold region flooding where independent shifts in both precipitation and temperature can have significant influence on high flows. This study explores changes in the magnitude and the timing of streamflow in 18 Swedish Sub-Arctic catchments over their full record periods available and a common period (1990-2013). The Mann-Kendall trend test was used to estimate changes in several hydrological signatures (e.g. annual maximum daily flow, mean summer flow, snowmelt onset). Further, trends in the flood frequency were determined by fitting an extreme value type I (Gumbel) distribution to test selected flood percentiles for stationarity using a generalized least squares regression approach. Results highlight shifts from snowmelt-dominated to rainfall-dominated flow regimes with all significant trends (at the 5% significance level) pointing toward (1) lower magnitudes in the spring flood; (2) earlier flood occurrence; (3) earlier snowmelt onset; and (4) decreasing mean summer flows. Decreasing trends in flood magnitude and mean summer flows suggest widespread permafrost thawing and are supported by increasing trends in annual minimum daily flows. Trends in selected flood percentiles showed an increase in extreme events over the full periods of record (significant for only four catchments), while trends were variable over the common period of data among the catchments. An uncertainty analysis emphasizes that the observed trends are highly sensitive to the period of record considered. As such, no clear overall regional hydrological response pattern could be determined suggesting that catchment response to regionally consistent changes in climatic drivers is strongly influenced by their physical

  8. Two case studies and a review of paroxysmal cold hemoglobinuria.

    Science.gov (United States)

    Slemp, Stephanie N; Davisson, Suzanne M; Slayten, Jayanna; Cipkala, Douglas A; Waxman, Dan A

    2014-01-01

    Paroxysmal cold hemoglobinuria (PCH) is an acquired hemolytic anemia caused by immunoglobulin G (IgG) antibodies that sensitize red blood cells (RBCs) at cold temperatures by fixing complement to the RBCs causing intravascular hemolysis on rewarming. PCH usually appears in young children as recurrent high fevers, chills, and passage of red-brown urine. The diagnostic test for PCH is the Donath-Landsteiner test, an in vitro assay for biphasic hemolysis. Herein, we present 2 cases of PCH that occurred within 12 months of each other. We quickly diagnosed the second case and treated the patient successfully, in part due to our recognition of its characteristics based on the first case. PCH is a hemolytic anemia for which there is a specific diagnostic test; the timely recognition of this entity by physicians and laboratory staff will allow prompt, supportive therapy and will raise the odds of quick resolution of hemolysis. Copyright© by the American Society for Clinical Pathology (ASCP).

  9. Antihistamines for the common cold.

    Science.gov (United States)

    De Sutter, An I M; Saraswat, Avadhesh; van Driel, Mieke L

    2015-11-29

    The common cold is an upper respiratory tract infection, most commonly caused by a rhinovirus. It affects people of all age groups and although in most cases it is self limiting, the common cold still causes significant morbidity. Antihistamines are commonly offered over the counter to relieve symptoms for patients affected by the common cold, however there is not much evidence of their efficacy. To assess the effects of antihistamines on the common cold. We searched CENTRAL (2015, Issue 6), MEDLINE (1948 to July week 4, 2015), EMBASE (2010 to August 2015), CINAHL (1981 to August 2015), LILACS (1982 to August 2015) and Biosis Previews (1985 to August 2015). We selected randomised controlled trials (RCTs) using antihistamines as monotherapy for the common cold. We excluded any studies with combination therapy or using antihistamines in patients with an allergic component in their illness. Two authors independently assessed trial quality and extracted data. We collected adverse effects information from the included trials. We included 18 RCTs, which were reported in 17 publications (one publication reports on two trials) with 4342 participants (of which 212 were children) suffering from the common cold, both naturally occurring and experimentally induced. The interventions consisted of an antihistamine as monotherapy compared with placebo. In adults there was a short-term beneficial effect of antihistamines on severity of overall symptoms: on day one or two of treatment 45% had a beneficial effect with antihistamines versus 38% with placebo (odds ratio (OR) 0.74, 95% confidence interval (CI) 0.60 to 0.92). However, there was no difference between antihistamines and placebo in the mid term (three to four days) to long term (six to 10 days). When evaluating individual symptoms such as nasal congestion, rhinorrhoea and sneezing, there was some beneficial effect of the sedating antihistamines compared to placebo (e.g. rhinorrhoea on day three: mean difference (MD) -0

  10. Cold atoms close to surfaces

    DEFF Research Database (Denmark)

    Krüger, Peter; Wildermuth, Stephan; Hofferberth, Sebastian

    2005-01-01

    Microscopic atom optical devices integrated on atom chips allow to precisely control and manipulate ultra-cold (T atoms and Bose-Einstein condensates (BECs) close to surfaces. The relevant energy scale of a BEC is extremely small (down to ... be utilized as a sensor for variations of the potential energy of the atoms close to the surface. Here we describe how to use trapped atoms as a measurement device and analyze the performance and flexibility of the field sensor. We demonstrate microscopic magnetic imaging with simultaneous high spatial...

  11. Revisiting the Cold ILC Parameters

    CERN Document Server

    Padamsee, Hasan

    2005-01-01

    At the first ILC Workshop, discussions were underway to re-examine the parameters of the cold ILC. Using the TESLA parameters MathCad program developed in 1991, I examined several variations to explore consequences to the capital and operating costs of the linac (cryomodules, RF, & refrigerator). The cost coefficients were chosen to match the distribution of the above items in the TESLA TDR at 25 MV/m. One parameter varied is the gradient from 25 to 50 MV/m coupled with a realistic Q as well as an optimistic Q (1010

  12. Probing Cold Dense Nuclear Matter

    Energy Technology Data Exchange (ETDEWEB)

    Subedi, Ramesh; Shneor, R.; Monaghan, Peter; Anderson, Bryon; Aniol, Konrad; Annand, John; Arrington, John; Benaoum, Hachemi; Benmokhtar, Fatiha; Bertozzi, William; Boeglin, Werner; Chen, Jian-Ping; Choi, Seonho; Cisbani, Evaristo; Craver, Brandon; Frullani, Salvatore; Garibaldi, Franco; Gilad, Shalev; Gilman, Ronald; Glamazdin, Oleksandr; Hansen, Jens-Ole; Higinbotham, Douglas; Holmstrom, Timothy; Ibrahim, Hassan; Igarashi, Ryuichi; De Jager, Cornelis; Jans, Eddy; Jiang, Xiaodong; Kaufman, Lisa; Kelleher, Aidan; Kolarkar, Ameya; Kumbartzki, Gerfried; LeRose, John; Lindgren, Richard; Liyanage, Nilanga; Margaziotis, Demetrius; Markowitz, Pete; Marrone, Stefano; Mazouz, Malek; Meekins, David; Michaels, Robert; Moffit, Bryan; Perdrisat, Charles; Piasetzky, Eliazer; Potokar, Milan; Punjabi, Vina; Qiang, Yi; Reinhold, Joerg; Ron, Guy; Rosner, Guenther; Saha, Arunava; Sawatzky, Bradley; Shahinyan, Albert; Sirca, Simon; Slifer, Karl; Solvignon, Patricia; Sulkosky, Vince; Sulkosky, Vincent; Sulkosky, Vince; Sulkosky, Vincent; Urciuoli, Guido; Voutier, Eric; Watson, John; Weinstein, Lawrence; Wojtsekhowski, Bogdan; Wood, Stephen; Zheng, Xiaochao; Zhu, Lingyan

    2008-06-01

    The protons and neutrons in a nucleus can form strongly correlated nucleon pairs. Scattering experiments, in which a proton is knocked out of the nucleus with high-momentum transfer and high missing momentum, show that in carbon-12 the neutron-proton pairs are nearly 20 times as prevalent as proton-proton pairs and, by inference, neutron-neutron pairs. This difference between the types of pairs is due to the nature of the strong force and has implications for understanding cold dense nuclear systems such as neutron stars.

  13. Influence of Hole Cold Expansion on Microstructure and Fatigue Life of 2124 Aluminum Alloy

    Directory of Open Access Journals (Sweden)

    YI Linna

    2016-10-01

    Full Text Available The change of fatigue life and microstructure of 2124-T851 thick plate after cold expanded with different deformation was studied by fatigue test, TEM, SEM and X-ray diffraction apparatus. The results show that the fatigue life increases with the increase of expanded deformation until the maximum value is reached, and then decreased rapidly with the increase of expanded deformation. At 0.4 mm expanded deformation, fatigue life reach peak value, which is 12.66 times of the non-cold-worked specimens. The microstructure research results show that the residual compressive stress and dislocation cell structure form around the cold-worked holes during the cold expansion, and increase quickly with the expanded deformation. The strengthened layer retarded the fatigue crack growth rate. The appropriate cold expanded deformation can improve the surface roughness of hole, and retard the initiation of fatigue crack, consequently improving the whole fatigue life.

  14. Fatigue Crack Growth Characteristics of Cold Stretched STS 304 Welded Joint

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jeong Won; Na, Seong Hyeon; Yoon, Dong Hyun; Kim, Jae Hoon [Chungnam Nat’l Univ., Daejeon (Korea, Republic of); Kim, Young Kyun; Kim, Ki Dong [Korea Gas Coporation R& D Division, Daejeon (Korea, Republic of)

    2017-09-15

    STS 304 steel is used as pressure vessel material, and although it exhibits excellent mechanical characteristics at a low temperature, it is heavier than other materials. To address this issue, a method using cold-stretching techniques for STS 304 can be applied. In this study, a cold-stretching part and welded joint specimen were directly obtained from a cold-stretching pressure vessel manufactured according to ASME code. Fatigue crack propagation tests were carried out at room temperature and -170℃ using the compliance method for stress ratios of 0.1 and 0.5. The results indicate that crack growth rate of the welded joint is higher than that of the cold-stretching part within the same stress intensity factor range. The outcome of this work is expected to serve as a basis for the development of a cold-stretched STS 304 pressure vessel.

  15. Thermoregulation in cold- and noncold-acclimated rats cold exposed in hypergravic fields

    Science.gov (United States)

    Horowitz, J. M.; Horwitz, B. A.; Monson, C. B.

    1983-01-01

    The effect of hypergravity on thermoregulation processes is investigated experimentally in rats. Hooded male Long-Evans rats were kept for 6 weeks at 5 or 23 C (cold-acclimated and noncold-acclimated groups, CA and NCA) prior to testing. One test protocol comprised sequential 1-h exposures to 23 C at 1 G, 23 C at 3 G (in a 2.1-m radius centrifuge; -Gx), 8 C at 3 G, 8 C at 1 G, and finally 23 C at 1 G, with continuous measurement of the oxygen consumption. In a second protocol, restrained rats were exposed to 23 C at 1 G, 23 C at 3 G, and 10 C at 3 G, and core temperature changes were monitored. The results are presented in graphs and a table. Oxygen consumption doubled in both CA and NCA rats on exposure to cold at 1 G, but at 3 G NCA consumption decreased while CA consumption remained high. The CA rats were also more able to maintain core temperature at 3 G than the NCA rats. These differences are attributed to the nonshivering thermogenic processes developed in CA rats, which appear to be unaffected by hypergravity.

  16. Diagnosis and management of cold urticaria.

    Science.gov (United States)

    Singleton, Reid; Halverstam, Caroline P

    2016-01-01

    Cold urticaria is a physical urticaria characterized by a localized or systemic eruption of papules upon exposure of the skin to cold air, liquids, and/or objects. In some cases, angioedema and anaphylaxis also may occur. The symptoms of cold urticaria can have a negative impact on patients' quality of life. Second-generation H1 antihistamines are the first line of treatment in cold urticaria; however, patients who are unresponsive to initial treatment with H1 antihistamines may require further management options. Avoidance of cold exposure is the most effective prophylactic measure. In mild to moderate cases, the primary goal of therapy is to improve the patient's quality of life. In more severe cases, treatment measures to protect the patient's airway, breathing, and circulation may be necessary. We report the case of a 23-year-old man with cold urticaria who was refractory to initial therapy with H1 antihistamines. A review of the literature also is provided.

  17. International workshop on cold neutron sources

    Energy Technology Data Exchange (ETDEWEB)

    Russell, G.J.; West, C.D. (comps.) (Los Alamos National Lab., NM (United States))

    1991-08-01

    The first meeting devoted to cold neutron sources was held at the Los Alamos National Laboratory on March 5--8, 1990. Cosponsored by Los Alamos and Oak Ridge National Laboratories, the meeting was organized as an International Workshop on Cold Neutron Sources and brought together experts in the field of cold-neutron-source design for reactors and spallation sources. Eighty-four people from seven countries attended. Because the meeting was the first of its kind in over forty years, much time was spent acquainting participants with past and planned activities at reactor and spallation facilities worldwide. As a result, the meeting had more of a conference flavor than one of a workshop. The general topics covered at the workshop included: Criteria for cold source design; neutronic predictions and performance; energy deposition and removal; engineering design, fabrication, and operation; material properties; radiation damage; instrumentation; safety; existing cold sources; and future cold sources.

  18. Cold dark matter from the hidden sector

    Energy Technology Data Exchange (ETDEWEB)

    Arias, Paola [Deutsches Elektronen-Synchrotron (DESY), Hamburg (Germany); Pontificia Univ. Catolica de Chile, Santiago (Chile). Facultad de Fisica

    2012-02-15

    Weakly interacting slim particles (WISPs) such as hidden photons (HP) and axion-like particles (ALPs) have been proposed as cold dark matter candidates. They might be produced non-thermally via the misalignment mechanism, similarly to cold axions. In this talk we review the main processes of thermalisation of HP and we compute the parameter space that may survive as cold dark matter population until today. Our findings are quite encouraging for experimental searches in the laboratory in the near future.

  19. Avionics Box Cold Plate Damage Prevention

    Science.gov (United States)

    Stambolian, Damon; Larcher, Steven; Henderson, Gena; Tran, Donald

    2011-01-01

    Over the years there have been several occurrences of damage to Space Shuttle Orbiter cold plates during removal and replacement of avionics boxes. Thus a process improvement team was put together to determine ways to prevent these kinds of damage. From this effort there were many solutions including, protective covers, training, and improved operations instructions. The focus of this paper is to explain the cold plate damage problem and the corrective actions for preventing future damage to aerospace avionics cold plate designs.

  20. Review on Cold-Formed Steel Connections

    OpenAIRE

    Lee, Yeong Huei; Tan, Cher Siang; Mohammad, Shahrin; Md Tahir, Mahmood; Shek, Poi Ngian

    2014-01-01

    The concept of cold-formed light steel framing construction has been widespread after understanding its structural characteristics with massive research works over the years. Connection serves as one of the important elements for light steel framing in order to achieve its structural stability. Compared to hot-rolled steel sections, cold-formed steel connections perform dissimilarity due to the thin-walled behaviour. This paper aims to review current researches on cold-formed steel connection...

  1. PERFORMANCE SIMULATION OF COLD STORAGE USING ENERGYPLUS

    OpenAIRE

    ASHISH S. UTAGE; K. V. MALI; A. D. KADAM

    2013-01-01

    The present work deals with the study of cold storage refrigeration plant and simulation of refrigeration system to evaluate the cooling load and annual energy consumption for cold storage applications. The specific temperature and humidity range is required for properly storing any particular food and thus facilitates its preservation for a longer duration of time. The present cold storage capacity in India is grossly inadequate and with a positive future outlook for the agro, food processin...

  2. Inhibition of common cold-induced aggravation of childhood asthma by leukotriene receptor antagonists.

    Science.gov (United States)

    Yoshihara, Shigemi; Fukuda, Hironobu; Abe, Toshio; Nishida, Mitsuhiro; Yamada, Yumi; Kanno, Noriko; Arisaka, Osamu

    2012-09-01

    Virus infection is an important risk factor for aggravation of childhood asthma. The objective of this study was to examine the effect of drugs on aggravation of asthma induced by a common cold. Asthma control was examined in a survey of 1,014 Japanese pediatric patients with bronchial asthma. The occurrence of common cold, asthma control, and drugs used for asthma control were investigated using a modified Childhood Asthma Control Test (C-ACT) for patients aged common cold and aggravation of asthma were significantly higher in patients aged common cold-induced aggravation was significantly less effective in patients aged common cold, asthma control was significantly more effective for those treated with leukotriene receptor antagonists (LTRAs) compared to treatment without LTRAs. Asthma control did not differ between patients who did or did not take inhaled corticosteroids or long-acting β2 stimulants. These findings showed a high prevalence of common cold in younger patients with childhood asthma and indicated that common cold can induce aggravation of asthma. LTRAs are useful for long-term asthma control in very young patients who develop an asthma attack due to a common cold.

  3. Global transcriptional profiling of a cold-tolerant rice variety under moderate cold stress reveals different cold stress response mechanisms.

    Science.gov (United States)

    Zhao, Junliang; Zhang, Shaohong; Yang, Tifeng; Zeng, Zichong; Huang, Zhanghui; Liu, Qing; Wang, Xiaofei; Leach, Jan; Leung, Hei; Liu, Bin

    2015-07-01

    Gene expression profiling under severe cold stress (4°C) has been conducted in plants including rice. However, rice seedlings are frequently exposed to milder cold stresses under natural environments. To understand the responses of rice to milder cold stress, a moderately low temperature (8°C) was used for cold treatment prior to genome-wide profiling of gene expression in a cold-tolerant japonica variety, Lijiangxintuanheigu (LTH). A total of 5557 differentially expressed genes (DEGs) were found at four time points during moderate cold stress. Both the DEGs and differentially expressed transcription factor genes were clustered into two groups based on their expression, suggesting a two-phase response to cold stress and a determinative role of transcription factors in the regulation of stress response. The induction of OsDREB2A under cold stress is reported for the first time in this study. Among the anti-oxidant enzyme genes, glutathione peroxidase (GPX) and glutathione S-transferase (GST) were upregulated, suggesting that the glutathione system may serve as the main reactive oxygen species (ROS) scavenger in LTH. Changes in expression of genes in signal transduction pathways for auxin, abscisic acid (ABA) and salicylic acid (SA) imply their involvement in cold stress responses. The induction of ABA response genes and detection of enriched cis-elements in DEGs suggest that ABA signaling pathway plays a dominant role in the cold stress response. Our results suggest that rice responses to cold stress vary with the specific temperature imposed and the rice genotype. © 2014 Scandinavian Plant Physiology Society.

  4. Cold vacuum drying facility design requirements

    Energy Technology Data Exchange (ETDEWEB)

    IRWIN, J.J.

    1999-07-01

    This document provides the detailed design requirements for the Spent Nuclear Fuel Project Cold Vacuum Drying Facility. Process, safety, and quality assurance requirements and interfaces are specified.

  5. Review on Cold-Formed Steel Connections

    Science.gov (United States)

    Tan, Cher Siang; Mohammad, Shahrin; Md Tahir, Mahmood; Shek, Poi Ngian

    2014-01-01

    The concept of cold-formed light steel framing construction has been widespread after understanding its structural characteristics with massive research works over the years. Connection serves as one of the important elements for light steel framing in order to achieve its structural stability. Compared to hot-rolled steel sections, cold-formed steel connections perform dissimilarity due to the thin-walled behaviour. This paper aims to review current researches on cold-formed steel connections, particularly for screw connections, storage rack connections, welded connections, and bolted connections. The performance of these connections in the design of cold-formed steel structures is discussed. PMID:24688448

  6. Review on cold-formed steel connections.

    Science.gov (United States)

    Lee, Yeong Huei; Tan, Cher Siang; Mohammad, Shahrin; Tahir, Mahmood Md; Shek, Poi Ngian

    2014-01-01

    The concept of cold-formed light steel framing construction has been widespread after understanding its structural characteristics with massive research works over the years. Connection serves as one of the important elements for light steel framing in order to achieve its structural stability. Compared to hot-rolled steel sections, cold-formed steel connections perform dissimilarity due to the thin-walled behaviour. This paper aims to review current researches on cold-formed steel connections, particularly for screw connections, storage rack connections, welded connections, and bolted connections. The performance of these connections in the design of cold-formed steel structures is discussed.

  7. Review on Cold-Formed Steel Connections

    Directory of Open Access Journals (Sweden)

    Yeong Huei Lee

    2014-01-01

    Full Text Available The concept of cold-formed light steel framing construction has been widespread after understanding its structural characteristics with massive research works over the years. Connection serves as one of the important elements for light steel framing in order to achieve its structural stability. Compared to hot-rolled steel sections, cold-formed steel connections perform dissimilarity due to the thin-walled behaviour. This paper aims to review current researches on cold-formed steel connections, particularly for screw connections, storage rack connections, welded connections, and bolted connections. The performance of these connections in the design of cold-formed steel structures is discussed.

  8. IMPROVED, FAVORABLE FOR ENVIRONMENT POLYURETHANE COLD-BOX-PROCESS (COLD BOX «HUTTENES-ALBERTUS» .

    Directory of Open Access Journals (Sweden)

    A. Sergini

    2005-01-01

    Full Text Available The results of the laboratory and industrial investigations, the purpose of which is improvement of the classical Cold-box-process, i.e. the process of the slugs hardening in cold boxes, are presented.

  9. Letter report: Cold crucible melter assessment

    Energy Technology Data Exchange (ETDEWEB)

    Elliott, M.L.

    1996-03-01

    One of the activities of the PNL Vitrification Technology Development (PVTD) Project is to assist the Tank Waste Remediation Systems (TWRS) Program in determining which melter systems should be performance tested for potential implementation in the high-level waste (HLW) vitrification plant. The Richland Operations Office (RL) has recommended that the Cold Crucible Melter (CCM) be evaluated as a candidate ``next generation`` melter. As a result, the CCM System Evaluation cost account was established under the PVTD Project so that the CCM could be initially assessed on a high-priority basis. This letter report summarizes a brief initial review and assessment of the CCM. Using the recommendations made in this document, Westinghouse Hanford Company (WHC) and RL will make a decision regarding the urgency of performance testing the CCM. If the decision is favorable, a subcontract will be negotiated for performance testing of a CCM using Hanford HLW simulants in a pilot-scale facility. Because of the aggressive nature of the schedule, the CCM evaluation was not rigorous. The evaluation consisted of a literature review and interviews with proponents of the technology during a recent trip to France. This letter report summarizes the evaluation and makes recommendations regarding further work in this area.

  10. Simulation and optimization of the cold roll-forming process

    Science.gov (United States)

    Sheu, Jinn-Jong

    2004-06-01

    In this paper, the cold roll-forming process of steel was simulated. The FEM model of rollers was built in the LS-DYNA software. There are six stands used in the cold-roll-forming process simulation. The frictions of the tools were determined by the comparison of the cold-roll-forming results and the simulation deformation. Many friction conditions were tested to approach the experimental results of the forming experiments. The blanks were pushed through the rollers in the roll-forming machine. While in the simulation, the rollers were running over the fixed-end blank instead of moving the materials. The resulted motion is the same but the boundary conditions were easier to specify and control. The rolling speeds in the simulation were higher to save the calculation time but still confirm to the experiment results. The simulation results shown the axial and the shear strains were induced during the bending process of sheet metal. The thickness of the sheet metal was varied very slightly during the roll-forming process. The dimension and shape of the cold roll-formed specimens were in good agreement with the experiment results. The Taguchi method was adopted to design an optimum roll flower.

  11. Shape recovery of PET foams after cold compression

    Science.gov (United States)

    Santo, Loredana; Bellisario, Denise; Quadrini, Fabrizio

    2016-10-01

    In this study, the recovery properties of thermoplastic foam are discussed. The feasibility of using this foam as core for the production of a shape memory sandwich with self-repairing properties is evaluated. PET foams have been extracted from a panel of PET foam in order to test the foam in the three space directions. Small cubic samples were then subjected to memory-recovery cycle. This cycle consisted of a cold compression to reduce the foam sample thickness up to 50%, and a subsequent recovery of the shape by heating the samples in a muffle. This way, it was possible to evaluate the effect of anisotropy on strength, stiffness and shape recovery of the PET foam. Afterwards, compression tests have been repeated to evaluate residual properties of PET foam after cold compression and hot recovery. Results confirm the ability of this class of materials to easily change and recovery their shape.

  12. Cold-induced vasodilatation in cold-intolerant rats after nerve injury

    NARCIS (Netherlands)

    Smits, E.S.; Duraku, L.S.; Niehof, S.P.; Daanen, H.A.M.; Hovius, S.E.R.; Selles, R.W.; Walbeehm, E.T.

    2013-01-01

    Purpose Cold-induced vasodilatation (CIVD) is a cyclic regulation of blood flow during prolonged cooling of protruding body parts. It is generally considered to be a protective mechanism against local cold injuries and cold intolerance after peripheral nerve injury. The aim of this study was to

  13. Cold-induced vasodilatation in cold-intolerant rats after nerve injury

    NARCIS (Netherlands)

    Smits, E.S.; Duraku, L.S.; Niehof, S.P.; Daanen, H.A.M.; Hovius, S.E.R.; Selles, R.W.; Walbeehm, E.T.

    2013-01-01

    Summary Purpose: Cold-induced vasodilatation (CIVD) is a cyclic regulation of blood flow during prolonged cooling of protruding body parts. It is generally considered to be a protective mechanism against local cold injuries and cold intolerance after peripheral nerve injury. The aim of this study

  14. Age and Ethnic Differences in Cold Weather and Contagion Theories of Colds and Flu

    Science.gov (United States)

    Sigelman, Carol K.

    2012-01-01

    Age and ethnic group differences in cold weather and contagion or germ theories of infectious disease were explored in two studies. A cold weather theory was frequently invoked to explain colds and to a lesser extent flu but became less prominent with age as children gained command of a germ theory of disease. Explanations of how contact with…

  15. 77 FR 43117 - Meeting of the Cold War Advisory Committee for the Cold War Theme Study

    Science.gov (United States)

    2012-07-23

    ... National Park Service Meeting of the Cold War Advisory Committee for the Cold War Theme Study AGENCY: National Park Service, Interior. ACTION: Notice of meeting. SUMMARY: Notice is hereby given in accordance... make recommendations to the National Park Service (NPS) concerning the Cold War Theme Study. DATES: The...

  16. Cold metal transfer welding of AA1050 aluminum thin sheets

    OpenAIRE

    İrizalp,Alaattin Ozan; Durmuş,Hülya; Yüksel, Nilay; Türkmen,İlyas

    2016-01-01

    ABSTRACT This study was aimed to investigate the welding parameters on mechanical behavior of 2 mm thick AA1050 sheet materials joined by cold metal transfer (CMT) method. Macro structural examination showed that decreasing heat input decreased the pore size in the weld metal. Tensile test was applied and failure occurred in heat affected zone of aluminum sheet metal. Maximum tensile strength was found in the sample with minimum heat input. Heat affected zone was observed explicitly in the sa...

  17. Ductile damage prediction in different cold forming processes

    OpenAIRE

    Cao, Trong-Son; Bouchard, Pierre-Olivier; Montmitonnet, Pierre

    2015-01-01

    International audience; The purpose of the present paper is to show how and to what extent the introduction of refined, shear sensitive models improves on previous ones, based on triaxiality only, for the phenomenological description of ductile damage in bulk cold metal forming processes. Wire-drawing and wire rolling are taken as examples. A set of mechanical tests has been conducted: round bar, notched bar and plane strain tensions as well as torsion for pure shear deformation. Both constit...

  18. Grading of the Whealing Response in Cases with Cold Urticaria

    Directory of Open Access Journals (Sweden)

    J S Pasricha

    1980-01-01

    Full Text Available Seven cases having cold urticaria and showing whealing response to the cryo-stimulation test were tested again after adjusting the temperature of the exposure surface at 0, 5, 10, 15, 20, 25 and 30 degree C. to determine the maximum temperature capable of producing a wheal in the patient (CTW. It was 25 degree C. in 2 patients and 20 degree C. in 3. In the remaining 2 patients, whealing at the test site was absent with 30 degree C., incomplete with 25 degree C. and complete with 20 degree C. On repeating the CTW in 5 patients within 7 days, it was found to be the same.

  19. Corticosteroids for the common cold.

    Science.gov (United States)

    Hayward, Gail; Thompson, Matthew J; Perera, Rafael; Del Mar, Chris B; Glasziou, Paul P; Heneghan, Carl J

    2015-10-13

    The common cold is a frequent illness, which, although benign and self limiting, results in many consultations to primary care and considerable loss of school or work days. Current symptomatic treatments have limited benefit. Corticosteroids are an effective treatment in other upper respiratory tract infections and their anti-inflammatory effects may also be beneficial in the common cold. This updated review has included one additional study. To compare corticosteroids versus usual care for the common cold on measures of symptom resolution and improvement in children and adults. We searched Cochrane Central Register of Controlled Trials (CENTRAL 2015, Issue 4), which includes the Acute Respiratory Infections (ARI) Group's Specialised Register, the Database of Reviews of Effects (DARE) (2015, Issue 2), NHS Health Economics Database (2015, Issue 2), MEDLINE (1948 to May week 3, 2015) and EMBASE (January 2010 to May 2015). Randomised, double-blind, controlled trials comparing corticosteroids to placebo or to standard clinical management. Two review authors independently extracted data and assessed trial quality. We were unable to perform meta-analysis and instead present a narrative description of the available evidence. We included three trials (353 participants). Two trials compared intranasal corticosteroids to placebo and one trial compared intranasal corticosteroids to usual care; no trials studied oral corticosteroids. In the two placebo-controlled trials, no benefit of intranasal corticosteroids was demonstrated for duration or severity of symptoms. The risk of bias overall was low or unclear in these two trials. In a trial of 54 participants, the mean number of symptomatic days was 10.3 in the placebo group, compared to 10.7 in those using intranasal corticosteroids (P value = 0.72). A second trial of 199 participants reported no significant differences in the duration of symptoms. The single-blind trial in children aged two to 14 years, who were also

  20. Cold Injury and Perniosis (Chilblain

    Directory of Open Access Journals (Sweden)

    Tuba Tulay Koca

    2015-12-01

    Full Text Available Perniosis (chilblain is inflammatory cutaneous lesions located on acral surfaces (fingers, toes, nose, aurikula which present in association with cold exposure. They can appear as an idiopathic (primary dermatosis or with an underlying autoimmune disease (secondary. The primary or idiopathic form is not associated with an underlying disease and is clinically indistinguishable from the secondary form. The secondary form is associated with an underlying condition such as connective tissue disease, monoclonal gammopathy, cryoglobulinemia, or chronic myelomonocytic leukemia. Histopathology cannot accurately help distinguish the primary from secondary forms of chilblains. This review aims to raise the awareness of perniosis to avoid excessive investigation and anxiety and to help patients with only appropriate simple advice and treatment. [Archives Medical Review Journal 2015; 24(4.000: 463-471

  1. Stirling-type pulse tube refrigerator (PTR) with cold compression: Cold compressor, colder expander

    Science.gov (United States)

    Park, Jiho; Ko, Junseok; Cha, Jeongmin; Jeong, Sangkwon

    2016-03-01

    This research paper focuses on the performance prediction and its validation via experimental investigation of a Stirling-type pulse tube refrigerator (PTR) equipped with a cold linear compressor. When the working gas is compressed at cryogenic temperature, the acoustic power (PV power) can be directly transmitted through the regenerator to the pulsating tube without experiencing unnecessary precooling process. The required PV power generated by the linear compressor, furthermore, can be significantly diminished due to the relatively small specific volume of the working gas at low temperature. The PTR can reach lower temperature efficiently with higher heat lift at the corresponding temperature than other typical single-stage Stirling-type PTRs. Utilizing a cryogenic reservoir as a warm end and regulating the entire operating temperature range of the PTR will enable a PTR to operate efficiently under space environment. In this research, the experimental validation as a proof of concept was carried out to demonstrate the capability of PTR operating between 80 K and 40 K. The linear compressor was submerged in a liquid nitrogen bath and the lowest temperature was measured as 38.5 K. The test results were analyzed to identify loss mechanisms with the simple numerical computation (linear model) which considers the dynamic characteristics of the cold linear compressor with thermo-hydraulic governing equations for each of sub components of the PTR. All the mass flows and pressure waves were assumed to be sinusoidal.

  2. OTEC Cold Water Pipe-Platform Subsystem Dynamic Interaction Validation

    Energy Technology Data Exchange (ETDEWEB)

    Varley, Robert [Lockheed Martin Corporation, Manassas, VA (United States); Halkyard, John [John Halkyard and Associates, Houston, TX (United States); Johnson, Peter [BMT Scientific Marine Services, Inc., Houston, TX (United States); Shi, Shan [Houston Offshore Engineering, Houston, TX (United States); Marinho, Thiago [Federal Univ. of Rio de Janeiro (Brazil). LabOceano

    2014-05-09

    A commercial floating 100-megawatt (MW) ocean thermal energy conversion (OTEC) power plant will require a cold water pipe (CWP) with a diameter of 10-meter (m) and length of up to 1,000 m. The mass of the cold water pipe, including entrained water, can exceed the mass of the platform supporting it. The offshore industry uses software-modeling tools to develop platform and riser (pipe) designs to survive the offshore environment. These tools are typically validated by scale model tests in facilities able to replicate real at-sea meteorological and ocean (metocean) conditions to provide the understanding and confidence to proceed to final design and full-scale fabrication. However, today’s offshore platforms (similar to and usually larger than those needed for OTEC applications) incorporate risers (or pipes) with diameters well under one meter. Secondly, the preferred construction method for large diameter OTEC CWPs is the use of composite materials, primarily a form of fiber-reinforced plastic (FRP). The use of these material results in relatively low pipe stiffness and large strains compared to steel construction. These factors suggest the need for further validation of offshore industry software tools. The purpose of this project was to validate the ability to model numerically the dynamic interaction between a large cold water-filled fiberglass pipe and a floating OTEC platform excited by metocean weather conditions using measurements from a scale model tested in an ocean basin test facility.

  3. Surge Recovery Techniques for the Tevatron Cold Compressors

    Science.gov (United States)

    Martinez, A.; Klebaner, A. L.; Makara, J. N.; Theilacker, J. C.

    2006-04-01

    The Fermilab Tevatron cryogenic system utilizes high-speed centrifugal cold compressors, made by Ishikawajima-Harima Heavy Industries Co. Ltd. (IHI), for high-energy operations. The compressor is designed to pump 60 g/s of 3.6 K saturated helium vapor at a pressure ratio of 2.8, with an off-design range of 40 to 70 g/s and operating speeds between 40 and 95 krpm. Since initial commissioning in 1993, Tevatron transient conditions such as quench recovery have led to multiple-location machine trips as a result of the cold compressors entering the surge regime. Historically, compressors operating at lower inlet pressures and higher speeds have been especially susceptible to these machine trips and it was not uncommon to have multiple compressor trips during large multiple-house quenches. In order to cope with these events and limit accelerator down time, surge recovery techniques have been implemented in an attempt to prevent the compressors from tripping once the machine entered this surge regime. This paper discusses the different methods of surge recovery that have been employed. Data from tests performed at the Cryogenic Test Facility at Fermilab as well as actual Tevatron operational data were utilized. In order to aid in the determination of the surge region, a full mapping study was undertaken to characterize the entire pressure field of the cold compressor. These techniques were then implemented and tested at several locations in the Tevatron with some success.

  4. On-orbit low gravity cryogenic scientific investigations using the COLD-SAT Satellite

    Science.gov (United States)

    Bailey, W. J.

    1990-01-01

    The Cryogenic On-Orbit Liquid Depot Storage, Acquisition and Transfer (COLD-SAT) Satellite is an experimental spacecraft designed to investigate the systems and technologies required for an efficient, effective, and reliable management of cryogenic fluids in reduced-gravity space environment. This paper defines the technology needs and the accompanying experimental three-month baseline mission of the COLD-SAT Satellite; describes the experiment subsystems, major features, and rationale for satisfying primary and secondary experimental requirements, using LH2 as the test fluid; and presents the conceptual design of the COLD-SAT spacecraft subsystems which support the on-orbit experiment.

  5. Signal transduction during cold stress in plants.

    Science.gov (United States)

    Solanke, Amolkumar U; Sharma, Arun K

    2008-04-01

    Cold stress signal transduction is a complex process. Many physiological changes like tissue break down and senescence occur due to cold stress. Low temperature is initially perceived by plasma membrane either due to change in membrane fluidity or with the help of sensors like Ca(2+) permeable channels, histidine kinases, receptor kinases and phospholipases. Subsequently, cytoskeleton reorganization and cytosolic Ca(2+) influx takes place. Increase in cytosolic Ca(2+) is sensed by CDPKs, phosphatase and MAPKs, which transduce the signals to switch on transcriptional cascades. Photosynthetic apparatus have also been thought to be responsible for low temperature perception and signal transduction. Many cold induced pathways are activated to protect plants from deleterious effects of cold stress, but till date, most studied pathway is ICE-CBF-COR signaling pathway. However, the importance of CBF independent pathways in cold acclimation is supported by few Arabidopsis mutants' studies. Cold stress signaling has certain pathways common with other abiotic and biotic stress signaling which suggest cross-talks among these. Most of the economically important crops are sensitive to low temperature, but very few studies are available on cold susceptible crop plants. Therefore, it is necessary to understand signal transducing components from model plants and utilize that knowledge to improve survival of cold sensitive crop plants at low temperature.

  6. Cold and trapped metastable noble gases

    NARCIS (Netherlands)

    Vassen, W.; Cohen-Tannoudji, C.; Leduc, M.; Boiron, D.; Westbrook, C.I.; Truscott, A.; Baldwin, K.; Birkl, G.; Cancio, P.; Trippenbach, M.

    2012-01-01

    Experimental work on cold, trapped metastable noble gases is reviewed. The aspects which distinguish work with these atoms from the large body of work on cold, trapped atoms in general is emphasized. These aspects include detection techniques and collision processes unique to metastable atoms.

  7. Cold plasma processing to improve food safety

    Science.gov (United States)

    Cold plasma is an antimicrobial process being developed for application as a food processing technology. This novel intervention is the subject of an expanding research effort by groups around the world. A variety of devices can be used to generate cold plasma and apply it to the food commodity bein...

  8. 21 CFR 890.5700 - Cold pack.

    Science.gov (United States)

    2010-04-01

    ... Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES PHYSICAL MEDICINE DEVICES Physical Medicine Therapeutic Devices § 890.5700 Cold pack. (a) Identification. A cold pack is a device intended for medical purposes that consists of a compact fabric envelope...

  9. Solvability & risk factors: a cold case investigation

    National Research Council Canada - National Science Library

    Keglovits, Sally; McCrary, Gregg; Ramsland, Katherine

    2013-01-01

    ... cold case investigations, investigators must use best practices. COLD CASE IN FLORIDA On December 19, 1959, someone killed Christine and Cliff Walker in their modest home in Osprey, FL, along with their two children, Jimmy, 3, and Debbie, 2. Cliff worked the land, while Christine was a homemaker. She had several male admirers and was rumo...

  10. Relative Tolerance of Six Bactrocera (Diptera: Tephritidae) Species to Phytosanitary Cold Treatment.

    Science.gov (United States)

    Myers, Scott W; Cancio-Martinez, Elena; Hallman, Guy J; Fontenot, Emily A; Vreysen, Marc J B

    2016-12-01

    To compare relative cold treatment tolerance across the economically important tephritid fruit flies (Diptera: Tephritidae), Bactrocera carambolae Drew & Hancock, Bactrocera correcta (Bezzi), Bactrocera cucurbitae (Coquillett), four populations of Bactrocera dorsalis (Hendel), Bactrocera zonata (Saunders), and Bactrocera tryoni (Froggatt), eggs (in vitro), and larvae (in infested fruit or on carrot diet) were cold treated at 2.0 ± 0.2 °C for selected durations. The study was performed to assess whether a single (i.e., generic) cold treatment could be developed that would control the entire group of fruit flies that were tested. Probit regression models showed that the hierarchy of cold resistance was third-instar larvae reared on carrot diet > third-instar larvae reared on orange > eggs test in vitro. Differences in mortality responses of third-instar larvae reared in oranges across populations of B. dorsalis were observed only at subefficacious levels of control. The majority of Bactrocera species responded the same at the high levels of control demanded of phytosanitary treatments, which indicated that cold treatments would be similarly effective across the species and populations tested. B. cucurbitae was found to be the most cold tolerant of all the species tested. Published by Oxford University Press on behalf of Entomological Society of America 2016. This work is written by US Government employees and is in the public domain in the US.

  11. Acute cooling of the feet and the onset of common cold symptoms.

    Science.gov (United States)

    Johnson, Claire; Eccles, Ronald

    2005-12-01

    There is a common folklore that chilling of the body surface causes the development of common cold symptoms, but previous clinical research has failed to demonstrate any effect of cold exposure on susceptibility to infection with common cold viruses. This study will test the hypothesis that acute cooling of the feet causes the onset of common cold symptoms. 180 healthy subjects were randomized to receive either a foot chill or control procedure. All subjects were asked to score common cold symptoms, before and immediately after the procedures, and twice a day for 4/5 days. 13/90 subjects who were chilled reported they were suffering from a cold in the 4/5 days after the procedure compared to 5/90 control subjects (P=0.047). There was no evidence that chilling caused any acute change in symptom scores (P=0.62). Mean total symptom score for days 1-4 following chilling was 5.16 (+/-5.63 s.d. n=87) compared to a score of 2.89 (+/-3.39 s.d. n=88) in the control group (P=0.013). The subjects who reported that they developed a cold (n=18) reported that they suffered from significantly more colds each year (P=0.007) compared to those subjects who did not develop a cold (n=162). Acute chilling of the feet causes the onset of common cold symptoms in around 10% of subjects who are chilled. Further studies are needed to determine the relationship of symptom generation to any respiratory infection.

  12. Phenotypic and genetic characteristics associated with Listeria monocytogenes food chain isolates displaying enhanced and diminished cold tolerance

    DEFF Research Database (Denmark)

    Hingston, P.; Chen, J.; Laing, C.

    as intermediate. Draft whole genome sequencing was performed to elucidate potential genotype/phenotype correlations. Evidence for several overlapping geno- and phenotypes were observed. Notably, isolates with a wildtype invasion gene, inlA (n=119), had faster (p=rates at 4°C than strains...... between strains with varied cold tolerance. The objective of this study was to determine if Lm isolates with enhanced cold tolerance, exhibit other high risk characteristics that may add to their survival and/or pathogenicity. To accomplish this, 166 predominantly food/food plant Lm isolates were tested...... with a truncated version (n=47). Cold tolerant isolates were more likely to be tolerant to the other three stresses than intermediate and cold sensitive isolates. Similarly, cold sensitive isolates were more likely to be sensitive to the other stresses. Cold tolerant isolates had shorter (p=0.012) lag phases...

  13. Cold Hardiness of the Black Soldier Fly (Diptera: Stratiomyidae).

    Science.gov (United States)

    Spranghers, Thomas; Noyez, Annelies; Schildermans, Kristof; De Clercq, Patrick

    2017-08-01

    The black soldier fly, Hermetia illucens (L.), shows potential as a resource for animal feed. However, industrial production in regions where the insect is not native, like northwestern Europe, could lead to permanent establishment, which might entail environmental risks. In temperate climates, establishment depends on the insect's ability to overwinter. This study assessed the insect's cold hardiness by determining the supercooling point (SCP) and lower lethal time at 5 °C (LTime10,50,90) for different life stages. As diet or acclimation can influence cold hardiness, prepupae reared on different substrates and acclimated prepupae were tested in separate experiments. The SCP ranged from -7.3 °C for late-instar larvae to -13.7 °C for pupae. Prepupae reared on a highly nutritional substrate had a lower SCP compared with a control diet composed of chicken feed (-14.1 °C vs. -12.4 °C, respectively), whereas the SCP was unaffected by acclimation. Based on the LTime, prepupae and pupae were the most cold hardy life stages. Acclimated prepupae were most cold tolerant, with a LTime50 of 23 d. Based on an empirical relationship between LTime50 and field survival of various arthropods, it was predicted that H. illucens would survive about 47 d in the field during northwestern European winters. The results from this laboratory study suggest that H. illucens is rather unlikely to overwinter in northwestern Europe. However, caution is warranted given that diet and acclimation can influence the insect's cold hardiness and in the field the insect may survive in a diapausing state or in protected hibernacula. © The Authors 2017. Published by Oxford University Press on behalf of Entomological Society of America. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  14. Influence of selected factors on bovine spermatozoa cold shock resistance

    Directory of Open Access Journals (Sweden)

    Luděk Stádník

    2015-01-01

    Full Text Available The objectives of this study were to determine the effects of sire, extender, and addition of Low Density Lipoprotein (LDL to extenders used on the percentage rate of spermatozoa survival after cold shock. Two groups of extenders were compared: without LDL addition (control variants and LDL enriched (experimental variants. Three extenders were used: AndroMed®, Bioxcell®, and Triladyl®. Experimental variants included 4–8% LDL addition into the AndroMed® and Bioxcell® extenders, and 6–10% LDL addition into the Triladyl® extender. In total, 12 samples of fresh semen were collected from 4 bulls during a period of 8 weeks. Bovine spermatozoa cold shock resistance (1 ± 1 °C, 10 min was evaluated by the percentage rate of live sperm using eosin-nigrosine staining immediately and after heat incubation (37 ± 1 °C, 120 min. The results showed the effect of sire as important and individual differences between selected sires in their sperm resistance against cold shock were confirmed. AndroMed® and Bioxcell® were found to be providing better protection of bull semen to cold shock compared to Triladyl® due to lower decline of live sperm proportion. Our results detected a positive effect of LDL addition on sperm resistance against cold shock, especially on lower decrease of live sperm percentage rate after 120 min of the heat test (P < 0.05. Further studies are needed to assess the optimal concentration of LDL in various kinds of extenders as well to state ideal time and temperature conditions for ensuring LDL reaction with sperm.

  15. Performance House -- A Cold Climate Challenge Home

    Energy Technology Data Exchange (ETDEWEB)

    Puttagunta, S.; Grab, J.; Williamson, J.

    2013-08-01

    Working with builder partners on a test homes allows for vetting of whole-house building strategies to eliminate any potential unintended consequences prior to implementing these solution packages on a production scale. To support this research, CARB partnered with Preferred Builders Inc. on a high-performance test home in Old Greenwich, CT. The philosophy and science behind the 2,700 ft2 'Performance House' was based on the premise that homes should be safe, healthy, comfortable, durable, efficient, and adapt with the homeowners. The technologies and strategies used in the 'Performance House' were not cutting-edge, but simply 'best practices practiced'. The focus was on simplicity in construction, maintenance, and operation. When seeking a 30% source energy savings targets over a comparable 2009 IECC code-built home in the cold climate zone, nearly all components of a home must be optimized. Careful planning and design are critical. To help builders and architects seeking to match the performance of this home, a step-by-step guide through the building shell components of DOE's Challenge Home are provided in a pictorial story book. The end result was a DOE Challenge Home that achieved a HERS Index Score of 20 (43 without PV, the minimum target was 55 for compliance). This home was also awarded the 2012 HOBI for Best Green Energy Efficient Home from the Home Builders & Remodelers Association of Connecticut.

  16. Synthesis of superheavy elements by cold fusion

    Energy Technology Data Exchange (ETDEWEB)

    Hofmann, S. [GSI Helmholtzzentrum fuer Schwerionenforschung GmbH, Darmstadt (Germany); Frankfurt Univ. (Germany). Inst. fuer Kernphysik

    2011-07-01

    The new elements from Z = 107 to 112 were synthesized in cold fusion reactions based on targets of lead and bismuth. The principle physical concepts are presented which led to the application of this reaction type in search experiments for new elements. Described are the technical developments from early mechanical devices to experiments with recoil separators. An overview is given of present experiments which use cold fusion for systematic studies and synthesis of new isotopes. Perspectives are also presented for the application of cold fusion reactions in synthesis of elements beyond element 113, the so far heaviest element produced in a cold fusion reaction. Further, the transition of hot fusion to cold fusion is pointed out, which occurs in reactions for synthesis of elements near Z = 126 using actinide targets and beams of neutron rich isotopes of elements from iron to germanium. (orig.)

  17. Improving cold chain systems: Challenges and solutions.

    Science.gov (United States)

    Ashok, Ashvin; Brison, Michael; LeTallec, Yann

    2017-04-19

    While a number of new vaccines have been rolled out across the developing world (with more vaccines in the pipeline), cold chain systems are struggling to efficiently support national immunization programs in ensuring the availability of safe and potent vaccines. This article reflects on the Clinton Health Access Initiative, Inc. (CHAI) experience working since 2010 with national immunization programs and partners to improve vaccines cold chains in 10 countries-Ethiopia, Nigeria, Kenya, Malawi, Tanzania, Uganda, Cameroon, Mozambique, Lesotho and India - to identify the root causes and solutions for three common issues limiting cold chain performance. Key recommendations include: Collectively, the solutions detailed in this article chart a path to substantially improving the performance of the cold chain. Combined with an enabling global and in-country environment, it is possible to eliminate cold chain issues as a substantial barrier to effective and full immunization coverage over the next few years. Copyright © 2017. Published by Elsevier Ltd.

  18. Metrology of the LHC Dipole Cold Masses

    CERN Document Server

    Bajkó, M; Savary, F

    2002-01-01

    In order to provide the largest possible mechanical aperture for the LHC beam, the dipole cold masses have to match the circular trajectory of the particle beam. The requirements on the dipole cold mass geometry are dictated by the beam optics of the LHC machine and by the mechanical deformation limits of the interconnection zone. The geometry of the approximately 15 m long, 0.57 m diameter and 30 t weight dipole cold mass is verified by the measurement of the axes of the cold bore tubes. The tight tolerances imposed, necessitate the use of a high accuracy 3D measuring system based on optical methods. During the last 2 years, 6 prototypes and 4 pre-series magnets have been assembled at CERN. The summary of the results obtained on these cold masses is presented, as well as the evolution of the tooling and the measuring method.

  19. Cognitive Egocentrism Differentiates Warm and Cold People.

    Science.gov (United States)

    Boyd, Ryan L; Bresin, Konrad; Ode, Scott; Robinson, Michael D

    2013-02-01

    Warmth-coldness is a fundamental dimension of social behavior. Cold individuals are egocentric in their social relations, whereas warm individuals are not. Previous theorizing suggests that cognitive egocentrism underlies social egocentrism. It was hypothesized that higher levels of interpersonal coldness would predict greater cognitive egocentrism. Cognitive egocentrism was assessed in basic terms through tasks wherein priming a lateralized self-state biased subsequent visual perceptions in an assimilation-related manner. Such effects reflect a tendency to assume that the self's incidental state provides meaningful information concerning the external world. Cognitive egocentrism was evident at high, but not low, levels of interpersonal coldness. The findings reveal a basic difference between warm and cold people, encouraging future research linking cognitive egocentrism to variability in relationship functioning.

  20. Social science in the Cold War.

    Science.gov (United States)

    Engerman, David C

    2010-06-01

    This essay examines ways in which American social science in the late twentieth century was--and was not--a creature of the Cold War. It identifies important work by historians that calls into question the assumption that all social science during the Cold War amounts to "Cold War social science." These historians attribute significant agency to social scientists, showing how they were enmeshed in both long-running disciplinary discussions and new institutional environments. Key trends in this scholarship include a broadening historical perspective to see social scientists in the Cold War as responding to the ideas of their scholarly predecessors; identifying the institutional legacies of World War II; and examining in close detail the products of extramural--especially governmental--funding. The result is a view of social science in the Cold War in which national security concerns are relevant, but with varied and often unexpected impacts on intellectual life.

  1. Influence of coating defects on the corrosion behavior of cold sprayed refractory metals

    Science.gov (United States)

    Kumar, S.; Rao, A. Arjuna

    2017-02-01

    The defects in the cold sprayed coatings are critical in the case of corrosion performances of the coatings in aggressive conditions. To understand the influence of coating defects on corrosion, immersion tests have been carried out in HF solution for the cold sprayed and heat treated Titanium, Tantalum and Niobium coatings. Long duration immersion tests reveal inhomogeneous weight losses of the samples prepared at different heat treatment conditions. The weight loss for different coatings has been well corroborated with the coating defects and microstructures. Chemical and micro structural analysis elucidates the reason behind the inhomogeneous performance of different type of cold sprayed coatings in corrosion medium. In the case of cold sprayed titanium, formation of stable oxide along the inter-splat boundary hinders the aggressive attack of the corrosion medium which is not so in other cases.

  2. The impact of cold spells on mortality and effect modification by cold spell characteristics.

    Science.gov (United States)

    Wang, Lijun; Liu, Tao; Hu, Mengjue; Zeng, Weilin; Zhang, Yonghui; Rutherford, Shannon; Lin, Hualiang; Xiao, Jianpeng; Yin, Peng; Liu, Jiangmei; Chu, Cordia; Tong, Shilu; Ma, Wenjun; Zhou, Maigeng

    2016-12-06

    In China, the health impact of cold weather has received little attention, which limits our understanding of the health impacts of climate change. We collected daily mortality and meteorological data in 66 communities across China from 2006 to 2011. Within each community, we estimated the effect of cold spell exposure on mortality using a Distributed Lag Nonlinear Model (DLNM). We also examined the modification effect of cold spell characteristics (intensity, duration, and timing) and individual-specific factors (causes of death, age, gender and education). Meta-analysis method was finally used to estimate the overall effects. The overall cumulative excess risk (CER) of non-accidental mortality during cold spell days was 28.2% (95% CI: 21.4%, 35.3%) compared with non-cold spell days. There was a significant increase in mortality when the cold spell duration and intensity increased or occurred earlier in the season. Cold spell effects and effect modification by cold spell characteristics were more pronounced in south China. The elderly, people with low education level and those with respiratory diseases were generally more vulnerable to cold spells. Cold spells statistically significantly increase mortality risk in China, with greater effects in southern China. This effect is modified by cold spell characteristics and individual-level factors.

  3. The impact of cold spells on mortality and effect modification by cold spell characteristics

    Science.gov (United States)

    Wang, Lijun; Liu, Tao; Hu, Mengjue; Zeng, Weilin; Zhang, Yonghui; Rutherford, Shannon; Lin, Hualiang; Xiao, Jianpeng; Yin, Peng; Liu, Jiangmei; Chu, Cordia; Tong, Shilu; Ma, Wenjun; Zhou, Maigeng

    2016-12-01

    In China, the health impact of cold weather has received little attention, which limits our understanding of the health impacts of climate change. We collected daily mortality and meteorological data in 66 communities across China from 2006 to 2011. Within each community, we estimated the effect of cold spell exposure on mortality using a Distributed Lag Nonlinear Model (DLNM). We also examined the modification effect of cold spell characteristics (intensity, duration, and timing) and individual-specific factors (causes of death, age, gender and education). Meta-analysis method was finally used to estimate the overall effects. The overall cumulative excess risk (CER) of non-accidental mortality during cold spell days was 28.2% (95% CI: 21.4%, 35.3%) compared with non-cold spell days. There was a significant increase in mortality when the cold spell duration and intensity increased or occurred earlier in the season. Cold spell effects and effect modification by cold spell characteristics were more pronounced in south China. The elderly, people with low education level and those with respiratory diseases were generally more vulnerable to cold spells. Cold spells statistically significantly increase mortality risk in China, with greater effects in southern China. This effect is modified by cold spell characteristics and individual-level factors.

  4. Working smarter on cold cases: identifying factors associated with successful cold case investigations.

    Science.gov (United States)

    Davis, Robert C; Jensen, Carl J; Burgette, Lane; Burnett, Kathryn

    2014-03-01

    Cold case squads have garnered much attention; however, they have yet to undergo significant empirical scrutiny. In the present study, the authors interviewed investigators and reviewed 189 solved and unsolved cold cases in Washington, D.C., to determine whether there are factors that can predict cold case solvability. In the interviews, new information from witnesses or information from new witnesses was cited as the most prevalent reason for case clearance. The case reviews determined that there were factors in each of the following domains that predicted whether cases would be solved during cold case investigations: Crime Context, Initial Investigation Results, Basis for Opening Cold Case, and Cold Case Investigator Actions. The results suggest that it is possible to prioritize cold case work based on the likelihood of investigations leading to clearances. © 2014 American Academy of Forensic Sciences.

  5. Cold, cholinergic and aquagenic urticaria in children: presentation of three cases and review of the literature.

    Science.gov (United States)

    Arıkan-Ayyıldız, Zeynep; Işık, Sakine; Cağlayan-Sözmen, Sule; Karaman, Ozkan; Uzuner, Nevin

    2013-01-01

    Urticaria can be induced with a wide variety of environmental stimuli, such as cold, pressure, vibration, sunlight, exercise, temperature changes, heat, and water. Urticaria caused by physical factors has been reported as the cause of 6-17% of the chronic urticaria in children. We present three cases here - cholinergic, cold and aquagenic urticaria - in which the diagnosis was proven with exercise, ice-cube and water provocation tests, respectively.

  6. Cold Crucible Induction Melter Technology: Results of Laboratory Directed Research and Development

    Energy Technology Data Exchange (ETDEWEB)

    Gombert, Dirk; Richardson, John Grant

    2001-09-01

    This report provides a review of cold crucible induction melter (CCIM) technology and presents summaries of alternatives and design issues associated with major system components. The objective in this report is to provide background systems level information relating to development and application of cold crucible induction-heated melter technology for radiological waste processing. Included is a detailed description of the bench-top melter system at the V. G. Khlopin Radium Institute currently being used for characterization testing

  7. Joint and column behaviour of slotted cold-formed steel studs

    DEFF Research Database (Denmark)

    Andreassen, Michael Joachim; Jönsson, Jeppe

    2015-01-01

    Slotted cold-formed steel studs are used in load bearing external plasterboard walls. The cold-formed steel studs in these walls are supported by and joined to track profiles at the bottom and top level. In this paper the load bearing studs are tested in compression in order to observe......, and are both with and without web stiffeners to see the influence of these on the joint behaviour and load bearing capacity of the slotted coldformed steel studs....

  8. Development of a test and flight engineering oriented language, phase 3

    Science.gov (United States)

    Kamsler, W. F.; Case, C. W.; Kinney, E. L.; Gyure, J.

    1970-01-01

    Based on an analysis of previously developed test oriented languages and a study of test language requirements, a high order language was designed to enable test and flight engineers to checkout and operate the proposed space shuttle and other NASA vehicles and experiments. The language is called ALOFT (a language oriented to flight engineering and testing). The language is described, its terminology is compared to similar terms in other test languages, and its features and utilization are discussed. The appendix provides the specifications for ALOFT.

  9. Some Chinese folk prescriptions for wind-cold type common cold.

    Science.gov (United States)

    Hai-Long, Zhai; Shimin, Chen; Yalan, Lu

    2015-07-01

    Although self-limiting, the common cold (gǎn mào) is highly prevalent. There are no effective antivirals to cure the common cold and few effective measures to prevent it, However, for thousands years, Chinese people have treated the common cold with natural herbs, According to the traditional Chinese medicine (TCM) theory ( zhōng yī lǐ lùn), the common cold is considered as an exterior syndrome, which can be further divided into the wind-cold type ( fēng hán xíng), the wind-heat type ( fēng rè xíng), and the summer heat dampness type ( shǔ rè xíng). Since the most common type of common cold caught in winter and spring is the wind-cold type, the article introduced some Chinese folk prescriptions for the wind-cold type common cold with normal and weak physique, respectively. For thousands of years, Chinese folk prescriptions for the common cold, as complementary and alternative medicine (CAM; bǔ chōng yǔ tì dài yī xué), have been proven to be effective, convenient, cheap, and most importantly, safe. The Chinese folk prescriptions ( zhōng guó mín jiān chǔ fāng) for the wind-cold type common cold are quite suitable for general practitioners or patients with the wind-cold type common cold, to treat the disease. Of course, their pharmacological features and mechanisms of action need to be further studied.

  10. Influence of coating defects on the corrosion behavior of cold sprayed refractory metals

    Energy Technology Data Exchange (ETDEWEB)

    Kumar, S., E-mail: skumar@arci.res.in; Rao, A. Arjuna

    2017-02-28

    Highlights: • Long duration immersion tests reveal inhomogeneous weight losses. • The weight loss for different coatings are well corroborated with the coating defects. • Chemical and micro structural analysis elucidates the reason behind the in homogeneous performance of different type of cold sprayed coatings. • In cold sprayed titanium, formation of oxide along the inter-splat boundary hinders the aggressive attack of the medium. - Abstract: The defects in the cold sprayed coatings are critical in the case of corrosion performances of the coatings in aggressive conditions. To understand the influence of coating defects on corrosion, immersion tests have been carried out in HF solution for the cold sprayed and heat treated Titanium, Tantalum and Niobium coatings. Long duration immersion tests reveal inhomogeneous weight losses of the samples prepared at different heat treatment conditions. The weight loss for different coatings has been well corroborated with the coating defects and microstructures. Chemical and micro structural analysis elucidates the reason behind the inhomogeneous performance of different type of cold sprayed coatings in corrosion medium. In the case of cold sprayed titanium, formation of stable oxide along the inter-splat boundary hinders the aggressive attack of the corrosion medium which is not so in other cases.

  11. EDITORIAL: Focus on Cold and Ultracold Molecules FOCUS ON COLD AND ULTRACOLD MOLECULES

    Science.gov (United States)

    Carr, Lincoln D.; Ye, Jun

    2009-05-01

    Cold and ultracold molecules are the next wave of ultracold physics, giving rise to an exciting array of scientific opportunities, including many body physics for novel quantum phase transitions, new states of matter, and quantum information processing. Precision tests of fundamental physical laws benefit from the existence of molecular internal structure with exquisite control. The study of novel collision and reaction dynamics will open a new chapter of quantum chemistry. Cold molecules bring together researchers from a variety of fields, including atomic, molecular, and optical physics, chemistry and chemical physics, quantum information science and quantum simulations, condensed matter physics, nuclear physics, and astrophysics, a truly remarkable synergy of scientific explorations. For the past decade there have been steady advances in direct cooling techniques, from buffer-gas cooling to cold molecular beams to electro- and magneto-molecular decelerators. These techniques have allowed a large variety of molecules to be cooled for pioneering studies. Recent amazing advances in experimental techniques combining the ultracold and the ultraprecise have furthermore brought molecules to the point of quantum degeneracy. These latter indirect cooling techniques magnetically associate atoms from a Bose-Einstein condensate and/or a quantum degenerate Fermi gas, transferring at 90% efficiency highly excited Fano-Feshbach molecules, which are on the order of 10 000 Bohr radii in size, to absolute ground state molecules just a few Bohr across. It was this latter advance, together with significant breakthroughs in internal state manipulations, which inspired us to coordinate this focus issue now, and is the reason why we say the next wave of ultracold physics has now arrived. Whether directly or indirectly cooled, heteronuclear polar molecules offer distinct new features in comparison to cold atoms, while sharing all of their advantages (purity, high coherence

  12. Cold hardiness research on agricultural and horticultural crops in Finland

    Directory of Open Access Journals (Sweden)

    L. LINDÉN

    2008-12-01

    Full Text Available This paper represents an overview of cold hardiness research conducted on agricultural and horticultural crops, as well as on amenity plants in Finland. Inadequate freezing tolerance and/or winter hardiness often prevents introduction of new species and cultivars to Finland. Field observations on winter hardiness and more recently the results from laboratory freezing tests, have assisted breeders to select hardy genotypes. Research approaches for agricultural crops have evolved from observations on winter and frost damage to studies on molecular mechanisms of cold acclimation and freezing injury. The results of experiments on survival of winter cereals, grasses and clovers and frost tolerance of potato and turnip rape are discussed. The studies conducted on horticultural crops, including apple, strawberry, raspberry, currants, blueberry, sea buckthorn, perennial herbs as well as on ornamental trees and shrubs have included field evaluations of cultivars, or selections for winter hardiness, and studies on the effects of cultural management practices on winter survival. During the last decade detailed studies including controlled freezing tests have provided tools to assist in explanation of the underlying mechanisms of cold hardiness also in horticultural plants. ;

  13. Study of Cold Coiling Spring Steel on Microstructure and Cold Forming Performance

    Science.gov (United States)

    Jiang, Y.; Liang, Y. L.; Ming, Y.; Zhao, F.

    2017-09-01

    Medium-carbon cold-coiling locomotive spring steels were treated by a novel Q-P-T (quenching-partitioning-tempering) process. Scanning electron microscopy (SEM), transmission electron microscope (TEM) and X-ray diffraction (XRD) were used to characterize the relevant parameters of the steel. Results show that the microstructure of tested steel treated by Q-P-T process is a complex microstructures composed of martensite, bainite and retained austenite. The volume fraction of retained austenite (wt.%) is up to 31%. After pre-deforming and tempering again at 310°C, the plasticity of samples treated by Q-P-T process is still well. Fracture images show that the Q-P-T samples are ductile fracture. It is attributed to the higher volume fraction of the retained austenite and the interactions between the multi-phases in Q-P-T processed sample.

  14. Changes in the content of water-soluble vitamins in Actinidia chinensis during cold storage

    Directory of Open Access Journals (Sweden)

    Zhu Xian-Bo

    2016-01-01

    Full Text Available We assessed the effects of cold storage on nine water-soluble vitamins in 7 cultivars of Actinidia chinensis (kiwifruit using high-performance liquid chromatography. Samples were collected at three time points during cold storage: one day, 30 days, and when edible. We found that vitamin C in most cultivars was raised with cold storage, but there was no consistent increased or decreased trend for other water-soluble vitamins across cultivars in storage. After one day of cold storage, vitamins B1 and B2 were the most prevalent vitamins in Control (wild fruit, while vitamins B5 and B6 were most prevalent in the Hongyang and Qihong cultivars. However, B12 was the most prevalent vitamin in the Qihong cultivar after 30 days of cold storage. Vitamins B3, B7, B9, and C were detected at the edible time point in Huayou, Hongyang, Jinnong-2, and Control fruit. Vitamin contents varied significantly among cultivars of kiwifruit following different durations of cold storage. Out of the three durations tested, a period of 30 days in cold storage was the most suitable for the absorption of water-soluble vitamins by A. chinensis.

  15. Protection of feet in cold exposure.

    Science.gov (United States)

    Kuklane, Kalev

    2009-07-01

    The paper summarizes the research on cold protection of feet. There exist several conflicting requirements for the choice of the best suited footwear for cold exposure. These conflicts are related to various environmental factors, protection needs and user comfort issues. In order to reduce such conflicts and simplify the choice of proper footwear the paper suggests dividing the cold into specific ranges that are related to properties and state of water and its possibility to penetrate into, evaporate from or condensate in footwear. The thermo-physiological background and reactions in foot are briefly explained, and main problems and risks related to cold injuries, mechanical injuries and slipping discussed. Footwear thermal insulation is the most important factor for protection against cold. The issues related to measuring the insulation and the practical use of measured values are described, but also the effect of socks, and footwear size. Other means for reducing heat losses, such as PCM and electrical heating are touched. The most important variable that affects footwear thermal insulation and foot comfort is moisture in footwear. In combination with motion they may reduce insulation and thus protection against cold by 45%. The paper includes recommendations for better foot comfort in cold.

  16. Acute Cold / Restraint Stress in Castrated Rats

    Directory of Open Access Journals (Sweden)

    Farideh Zafari Zangeneh

    2008-09-01

    Full Text Available Objective: The present study aimed to determine whether castration altered osmotically stimulated vasopressin (VP release and urinary volume and what is the role of endocrine-stress axis in this process.Materials and methods: Totally 108 mice were studied in two main groups of castrated (n=78 and control (n=30. Each group was extracted by acute cold stress (4◦C for 2h/day, restraint stress (by syringes 60cc 2h/day and cold/restraint stress. The castrated group was treated in sub groups of testosterone, control (sesame oil as vehicle of testosterone. Propranolol as blocker of sympathetic nervous system was given to both groups of castrated mice and main control.Results: Our results showed that, there is interactions between testosterone and sympathetic nervous system on vasopressin, because urine volume was decreased only in testoctomized mice with cold/restraint and cold stress (P<0.001; propranolol as the antagonist of sympathetic nervous system could block and increase urine volume in castrated mice. This increased volume of urine was due to acute cold stress, not restraint stress (p<0.001. The role of testosterone, noradrenalin (NA and Vasopressin (VP in the acute cold stress is confirmed, because testosterone could return the effect of decreased urine volume in control group (P<0.001. Conclusion: Considering the effect of cold/restraint stress on urinary volume in castrated mice shows that there is interaction between sex hormone (testosterone, vasopressin and adrenergic systems.

  17. Cold Helium Gas Pressurization For Spacecraft Cryogenic Propulsion Systems

    Science.gov (United States)

    Morehead, Robert L.; Atwell. Matthew J.; Hurlbert, Eric A.; Melcher, J. C.

    2017-01-01

    To reduce the dry mass of a spacecraft pressurization system, helium pressurant may be stored at low temperature and high pressure to increase mass in a given tank volume. Warming this gas through an engine heat exchanger prior to tank pressurization both increases the system efficiency and simplifies the designs of intermediate hardware such as regulators, valves, etc. since the gas is no longer cryogenic. If this type of cold helium pressurization system is used in conjunction with a cryogenic propellant, though, a loss in overall system efficiency can be expected due to heat transfer from the warm ullage gas to the cryogenic propellant which results in a specific volume loss for the pressurant, interpreted as the Collapse Factor. Future spacecraft with cryogenic propellants will likely have a cold helium system, with increasing collapse factor effects as vehicle sizes decrease. To determine the collapse factor effects and overall implementation strategies for a representative design point, a cold helium system was hotfire tested on the Integrated Cryogenic Propulsion Test Article (ICPTA) in a thermal vacuum environment at the NASA Glenn Research Center Plum Brook Station. The ICPTA vehicle is a small lander-sized spacecraft prototype built at NASA Johnson Space Center utilizing cryogenic liquid oxygen/liquid methane propellants and cryogenic helium gas as a pressurant to operate one 2,800lbf 5:1 throttling main engine, two 28lbf Reaction Control Engines (RCE), and two 7lbf RCEs (Figure 1). This vehicle was hotfire tested at a variety of environmental conditions at NASA Plum Brook, ranging from ambient temperature/simulated high altitude, deep thermal/high altitude, and deep thermal/high vacuum conditions. A detailed summary of the vehicle design and testing campaign may be found in Integrated Cryogenic Propulsion Test Article Thermal Vacuum Hotfire Testing, AIAA JPC 2017.

  18. The new cold neutron tomography set-up at SINQ

    CERN Document Server

    Baechler, S; Cauwels, P; Dierick, M; Jolie, J; Materna, T; Mondelaers, W

    2002-01-01

    A new cold neutron tomography set-up is operational at the neutron spallation source SINQ of the Paul Scherrer Institute (PSI) in Villigen, Switzerland. The detection system is based on a sup 6 LiF/ZnS:Ag conversion screen and a CCD camera. Several tests have been carried out to characterize the quality of the tomography system, such as homogeneity, reproducibility, L/D-ratio and spatial resolution. The high flux and the good efficiency of the detector lead to very short exposure times. Thus, a typical set of tomography scans can be performed in only 20 min. Then, 3D computed tomography objects were calculated using the filtered back-projection reconstruction method. Initial results of various samples show that cold neutron tomography can be a useful tool for industry, geology and dentistry. Furthermore, suitable applications can be found in the field of archaeology.

  19. On a theory of the evolution of surface cold fronts

    Science.gov (United States)

    Levy, Gad; Bretherton, Christopher S.

    1987-01-01

    The governing vorticity and divergence equations in the surface layer are derived and the roles of the different terms and feedback mechanisms are investigated in semigeostrophic and nongeostrophic cold-frontal systems. A planetary boundary layer model is used to perform sensitivity tests to determine that in a cold front the ageostrophic feedback mechanism as defined by Orlanski and Ross tends to act as a positive feedback mechanism, enhancing vorticity and convergence growth. Therefore, it cannot explain the phase shift between convergence and vorticity as simulated by Orlanski and Ross. An alternative plausible, though tentative, explanation in terms of a gravity wave is offered. It is shown that when the geostrophic deformation increases, nonlinear terms in the divergence equation may become important and further destabilize the system.

  20. Fast Simulations of Gas Sloshing and Cold Front Formation

    Science.gov (United States)

    Roediger, E.; ZuHone, J. A.

    2012-01-01

    We present a simplified and fast method for simulating minor mergers between galaxy clusters. Instead of following the evolution of the dark matter halos directly by the N-body method, we employ a rigid potential approximation for both clusters. The simulations are run in the rest frame of the more massive cluster and account for the resulting inertial accelerations in an optimised way. We test the reliability of this method for studies of minor merger induced gas sloshing by performing a one-to-one comparison between our simulations and hydro+N-body ones. We find that the rigid potential approximation reproduces the sloshing-related features well except for two artifacts: the temperature just outside the cold fronts is slightly over-predicted, and the outward motion of the cold fronts is delayed by typically 200 Myr. We discuss reasons for both artifacts.

  1. Engineering Cold Stress Tolerance in Crop Plants

    Science.gov (United States)

    Sanghera, Gulzar S; Wani, Shabir H; Hussain, Wasim; Singh, N.B

    2011-01-01

    Plants respond with changes in their pattern of gene expression and protein products when exposed to low temperatures. Thus ability to adapt has an impact on the distribution and survival of the plant, and on crop yields. Many species of tropical or subtropical origin are injured or killed by non-freezing low temperatures, and exhibit various symptoms of chilling injury such as chlorosis, necrosis, or growth retardation. In contrast, chilling tolerant species are able to grow at such cold temperatures. Conventional breeding methods have met with limited success in improving the cold tolerance of important crop plants involving inter-specific or inter-generic hybridization. Recent studies involving full genome profiling/ sequencing, mutational and transgenic plant analyses, have provided a deep insight of the complex transcriptional mechanism that operates under cold stress. The alterations in expression of genes in response to cold temperatures are followed by increases in the levels of hundreds of metabolites, some of which are known to have protective effects against the damaging effects of cold stress. Various low temperature inducible genes have been isolated from plants. Most appear to be involved in tolerance to cold stress and the expression of some of them is regulated by C-repeat binding factor/ dehydration-responsive element binding (CBF/DREB1) transcription factors. Numerous physiological and molecular changes occur during cold acclimation which reveals that the cold resistance is more complex than perceived and involves more than one pathway. The findings summarized in this review have shown potential practical applications for breeding cold tolerance in crop and horticultural plants suitable to temperate geographical locations. PMID:21886453

  2. Engineering cold stress tolerance in crop plants.

    Science.gov (United States)

    Sanghera, Gulzar S; Wani, Shabir H; Hussain, Wasim; Singh, N B

    2011-03-01

    Plants respond with changes in their pattern of gene expression and protein products when exposed to low temperatures. Thus ability to adapt has an impact on the distribution and survival of the plant, and on crop yields. Many species of tropical or subtropical origin are injured or killed by non-freezing low temperatures, and exhibit various symptoms of chilling injury such as chlorosis, necrosis, or growth retardation. In contrast, chilling tolerant species are able to grow at such cold temperatures. Conventional breeding methods have met with limited success in improving the cold tolerance of important crop plants involving inter-specific or inter-generic hybridization. Recent studies involving full genome profiling/ sequencing, mutational and transgenic plant analyses, have provided a deep insight of the complex transcriptional mechanism that operates under cold stress. The alterations in expression of genes in response to cold temperatures are followed by increases in the levels of hundreds of metabolites, some of which are known to have protective effects against the damaging effects of cold stress. Various low temperature inducible genes have been isolated from plants. Most appear to be involved in tolerance to cold stress and the expression of some of them is regulated by C-repeat binding factor/ dehydration-responsive element binding (CBF/DREB1) transcription factors. Numerous physiological and molecular changes occur during cold acclimation which reveals that the cold resistance is more complex than perceived and involves more than one pathway. The findings summarized in this review have shown potential practical applications for breeding cold tolerance in crop and horticultural plants suitable to temperate geographical locations.

  3. Cold storage of rat hepatocyte spheroids.

    Science.gov (United States)

    Liu, Hongling; Yu, Yue; Glorioso, Jaime; Mao, Shennen; Rodysil, Brian; Amiot, Bruce P; Rinaldo, Piero; Nyberg, Scott L

    2014-01-01

    Cell-based therapies for liver disease rely on a high-quality supply of hepatocytes and a means for storage during transportation from site of isolation to site of usage. Unfortunately, frozen cryopreservation is associated with unacceptable loss of hepatocyte viability after thawing. The purpose of this study was to optimize conditions for cold storage of rat hepatocyte spheroids without freezing. Rat hepatocytes were isolated by a two-step perfusion method; hepatocyte spheroids were formed during 48 h of rocked culture in serum-free medium (SFM). Spheroids were then maintained in rocked culture at 37 °C (control condition) or cold stored at 4 °C for 24 or 48 h in six different cold storage solutions: SFM alone; SFM + 1 mM deferoxamine (Def); SFM + 1 μM cyclosporin A (CsA); SFM + 1 mM Def + 1 μM CsA, University of Wisconsin (UW) solution alone, UW + 1 mM Def. Performance metrics after cold storage included viability, gene expression, albumin production, and functional activity of cytochrome P450 enzymes and urea cycle proteins. We observed that cold-induced injury was reduced significantly by the addition of the iron chelator (Def) to both SFM and UW solution. Performance metrics (ammonia detoxification, albumin production) of rat hepatocyte spheroids stored in SFM + Def for 24 h were significantly increased from SFM alone and approached those in control conditions, while performance metrics after cold storage in SFM alone or cold storage for 48 h were both significantly reduced. A serum-free medium supplemented with Def allowed hepatocyte spheroids to tolerate 24 h of cold storage with less than 10% loss in viability and functionality. Further research is warranted to optimize a solution for extended cold storage of hepatocyte spheroids.

  4. Molecular switch for cold acclimation -- anatomy of the cold-inducible promoter in plants.

    Science.gov (United States)

    Jiang, Yue; Peng, Dan; Bai, Li-Ping; Ma, Hui; Chen, Li-Jing; Zhao, Ming-Hui; Xu, Zheng-Jin; Guo, Zhi-Fu

    2013-04-01

    In plants, a promoter is essential to drive the transcription and expression of genes under stress conditions. The cold-regulated promoter is an important molecular switch involved in transcriptional regulation of a dynamic network of genes associated with cold acclimation processes. However, the structure and functions of the cold-regulated promoter are ambiguous. In this review, we first describe the common type and structures of the cold-regulated promoter, such as the core promoter and transcription factor binding sites, and then discuss the synergistic actions of promoter elements and cold-regulated genes. We also describe the transcriptional responses and cross-talk among cold-regulated genes in the ICE-CBF-COR cold-response pathway. Many stress-inducible genes are known to be regulated by endogenous abscisic acid (ABA), which accumulates during osmotic and cold stress. We discuss the regulation of promoters of cold-inducible genes in ABA-dependent and ABA-independent regulatory systems. We also describe the cross-talk among gene networks regulated by different cis-acting regulatory elements. Finally, we propose potential further research on, and practical applications of, the cold-regulated promoter.

  5. Cold thermal injury from cold caps used for the prevention of chemotherapy-induced alopecia.

    Science.gov (United States)

    Belum, Viswanath Reddy; de Barros Silva, Giselle; Laloni, Mariana Tosello; Ciccolini, Kathryn; Goldfarb, Shari B; Norton, Larry; Sklarin, Nancy T; Lacouture, Mario E

    2016-06-01

    The use of scalp cooling for the prevention of chemotherapy-induced alopecia (CIA) is increasing. Cold caps are placed onto the hair-bearing areas of the scalp for varying time periods before, during, and after cytotoxic chemotherapy. Although not yet reported, improper application procedures could result in adverse events (AEs). At present, there are no evidence-based scalp cooling protocols, and there is no regulatory oversight of their use. To report the occurrence of cold thermal injury (frostbite) on the scalp, following the use of cold caps for the prevention of CIA. We identified four patients who developed cold thermal injuries on the scalp following the application of cold caps. Medical records were analyzed to retrieve the demographic and clinical characteristics. The cold thermal injuries in our patients were grade 1/2 in severity and improved with topical interventions and interruption of cold cap use, although grade 1 persistent alopecia ensued in 3 patients. The true incidence of such injuries in this setting, however, remains unknown. Cold thermal injuries are likely infrequent and preventable AEs that may result from improper device application procedures during cold cap use. Although these untoward events are usually mild to moderate in severity, the potential occurrence of long-term sequelae (e.g., permanent alopecia and scarring) or the need to discontinue cold cap use, are not known. Prospective studies are needed to further elucidate the risk and standardize healthcare delivery methods, and to improve patient/supportive/healthcare provider education.

  6. Hot flakes in cold cases.

    Science.gov (United States)

    Schneider, Harald; Sommerer, Thomas; Rand, Steve; Wiegand, Peter

    2011-07-01

    In the past, it was almost impossible for forensic scientists to separate DNA from an undefined number of different individuals in mixed stains where, for example, two or more suspects had handled the same weapon. Such samples often contain complex mixtures with the consequence of ambiguous or inconclusive mixed DNA profiles. Using the method described of comprehensive and/or targeted screening of shed cells adhering to tapings of garments or objects enables such stains to be individualized. To evaluate the method, 500 microscopically selected single skin flakes were analyzed using two different commercial STR kits to compare the success rates for each PCR typing system. The method has been validated for use in routine casework and has been shown to be rapid, sensitive, and reproducible. It can be predicted that many cases in the archives with body tapings, which have not yet been examined will benefit from this new or perhaps more appropriate, reanimated, technical development, and of particular importance are serious crimes, the so-called cold cases. The remarkable forensic value of this simple but time-consuming technique is exemplified by 2 out of approximately 100 cases already successfully solved using this approach.

  7. Microbiological interactions with cold plasma.

    Science.gov (United States)

    Bourke, P; Ziuzina, D; Han, L; Cullen, P J; Gilmore, B F

    2017-08-01

    There is a diverse range of microbiological challenges facing the food, healthcare and clinical sectors. The increasing and pervasive resistance to broad-spectrum antibiotics and health-related concerns with many biocidal agents drives research for novel and complementary antimicrobial approaches. Biofilms display increased mechanical and antimicrobial stability and are the subject of extensive research. Cold plasmas (CP) have rapidly evolved as a technology for microbial decontamination, wound healing and cancer treatment, owing to the chemical and bio-active radicals generated known collectively as reactive oxygen and nitrogen species. This review outlines the basics of CP technology and discusses the interactions with a range of microbiological targets. Advances in mechanistic insights are presented and applications to food and clinical issues are discussed. The possibility of tailoring CP to control specific microbiological challenges is apparent. This review focuses on microbiological issues in relation to food- and healthcare-associated human infections, the role of CP in their elimination and the current status of plasma mechanisms of action. © 2017 The Society for Applied Microbiology.

  8. Study of neutron focusing at the Texas Cold Neutron Source. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Wehring, B.W.; Uenlue, K.

    1996-12-19

    The goals of this three-year study were: (1) design a neutron focusing system for use with the Texas Cold Neutron Source (TCNS) to produce an intense beam of cold neutrons appropriate for prompt gamma activation analysis (PGAA); (2) orchestrate the construction of the focusing system, integrate it into the TCNS neutron guide complex, and measure its performance; and (3) design, setup, and test a cold-neutron PGAA system which utilizes the guided focused cold neutron beam. During the first year of the DOE grant, a new procedure was developed and used to design a focusing converging guide consisting of truncated rectangular cone sections. Detailed calculations were performed using a 3-D Monte Carlo code which the authors wrote to trace neutrons through the curved guide of the TCNS into the proposed converging guide. Using realistic reflectivities for Ni-Ti supermirrors, the authors obtained gains of 3 to 5 for 4 different converging guide geometries. During the second year of the DOE grant, the subject of this final report, Ovonic Synthetic Materials Company was contracted to build a converging neutron guide focusing system to the specifications. Considerable time and effort were spent working with Ovonics on selecting the materials for the converging neutron guide system. The major portion of the research on the design of a cold-neutron PGAA system was also completed during the second year. At the beginning of the third year of the grant, a converging neutron guide focusing system had been ordered, and a cold-neutron PGAA system had been designed. Since DOE did not fund the third year, there was no money to purchase the required equipment for the cold-neutron PGAA system and no money to perform tests of either the converging neutron guide or the cold-neutron PGAA system. The research already accomplished would have little value without testing the systems which had been designed. Thus the project was continued at a pace that could be sustained with internal funding.

  9. Individually ventilated cages impose cold stress on laboratory mice: a source of systemic experimental variability.

    Science.gov (United States)

    David, John M; Knowles, Scott; Lamkin, Donald M; Stout, David B

    2013-11-01

    Individual ventilated cages (IVC) are increasing in popularity. Although mice avoid IVC in preference testing, they show no aversion when provided additional nesting material or the cage is not ventilated. Given the high ventilation rate in IVC, we developed 3 hypotheses: that mice housed in IVC experience more cold stress than do mice housed in static cages; that IVC-induced cold stress affects the results of experiments using mice; and that, when provided shelters, mice behaviorally thermoregulate and thereby rescue the cold-stress effects of IVC. To test these hypotheses, we housed mice in IVC, IVC with shelters, and static cages maintained at 20 to 21 °C. We quantified the cold stress of each housing system on mice by assessing nonshivering thermogenesis and brown adipose vacuolation. To test housing effects in a common, murine model of human disease, we implanted mice with subcutaneous epidermoid carcinoma cells and quantified tumor growth, tumor metabolism, and adrenal weight. Mice housed in IVC had histologic signs of cold stress and significantly higher nonshivering thermogenesis, smaller subcutaneous tumors, lower tumor metabolism, and larger adrenal weights than did mice in static cages. Shelters rescued IVC-induced nonshivering thermogenesis, adrenal enlargement, and phenotype-dependent cold-mediated histologic changes in brown adipose tissue and tumor size. IVC impose chronic cold stress on mice, alter experimental results, and are a source of systemic confounders throughout rodent-dependent research. Allowing mice to exhibit behavioral thermoregulation through seeking shelter markedly rescues the experiment-altering effects of housing-imposed cold stress, improves physiologic uniformity, and increases experimental reproducibility across housing systems.

  10. The quality of cold smoked salmon

    DEFF Research Database (Denmark)

    Løje, Hanne

    2007-01-01

    The objective of this Ph. D. thesis was to study the liquid holding capacity/liquid loss of raw and smoked salmonids as affected by raw material and chill storage of the cold smoked product. The liquid holding capacity is an important quality parameter for cold smoked salmon. This study has shown...... of the smoked product affected the liquid holding capacity. Thus, the producers of cold smoked salmon should be aware of this and should have a careful control of the raw material especially regarding the lipid content....

  11. International cooperation in cold forging technology

    DEFF Research Database (Denmark)

    Bay, Niels; Lange, K

    1992-01-01

    International cooperation in the field of cold forging technology started in 1961 by formation of the OECD Group of Experts on Metal Forming. In 1967 this group was transformed into the International Cold Forging Group, ICFG, an independent body which has now been operative for 25 years. Members...... by cooperative activities or by instigating national research. These subgroups have produced 9 data sheets and 7 guidelines on subjects such as materials, tool design and construction, calculation methods for cold forging tools, manufacture of slugs, lubrication aspects and small quantity production. Plenary...

  12. Cold Antihydrogen for Precise Laser Spectroscopy

    CERN Multimedia

    Gabrielse, G S; Walz, J; Hessels, E A; Tan, J; Oelert, W; George, M C; Grzonka, D J; Kossick, M; Storry, C H; Sefzick, T

    2002-01-01

    %AD-2 %title\\\\ \\\\The Antihydrogen TRAP Collaboration (ATRAP) seeks to do precise laser spectroscopy of antihydrogen. Comparisons of antihydrogen and hydrogen atoms should provide the most stringent test of CPT invariance involving baryons and leptons. ATRAP is an expansion of the TRAP collaboration that developed the techniques to take CERN antiprotons from an energy of 6 MeV (momentum 100 MeV/c) all the way down to thermal equilibrium at 4 K for storage. This storage energy is lower than realized previously by more than ten orders of magnitude. The TRAP techniques include slowing, capturing, electron cooling and stacking of antiprotons. ATRAP and other collaborations will use antiprotons from the Antiproton Decelerator (AD). This new facility makes sense for such experiments because we showed that antiprotons can be accumulated in a trap at much lower expense than was required in the earlier CERN AC-AA-LEAR complex. In the closest approach yet to the production of cold antihydrogen, collaboration members wer...

  13. Spinifex People as Cold War Moderns

    Directory of Open Access Journals (Sweden)

    Greg Castillo

    2015-08-01

    Full Text Available Normal 0 false false false EN-US JA X-NONE /* Style Definitions */ table.MsoNormalTable {mso-style-name:"Table Normal"; mso-tstyle-rowband-size:0; mso-tstyle-colband-size:0; mso-style-noshow:yes; mso-style-priority:99; mso-style-parent:""; mso-padding-alt:0in 5.4pt 0in 5.4pt; mso-para-margin:0in; mso-para-margin-bottom:.0001pt; mso-pagination:widow-orphan; font-size:10.0pt; font-family:Verdana;} Aboriginal Australian contemporary artists create works that express indigenous traditions as well as the unprecedented conditions of global modernity. This is especially true for the founders of the Spinifex Arts Project, a collective established in 1997 to create so-called “government paintings”: the large-scale canvases produced as documents of land tenure used in negotiations with the government of Western Australia to reclaim expropriated desert homelands. British and Australian nuclear testing in the 1950s displaced the Anangu juta pila nguru, now known to us as the Spinifex people, from their nomadic lifeworld. Exodus and the subsequent struggle to regain lost homelands through paintings created as corroborating evidence for native title claims make Spinifex canvases not simply expressions of Tjukurpa, or “Dreamings,” but also artifacts of the atomic age and its impact on a culture seemingly far from the front lines of cold war conflict.

  14. The physiological role of fat body and muscle tissues in response to cold stress in the tropical cockroach Gromphadorhina coquereliana.

    Science.gov (United States)

    Chowański, Szymon; Lubawy, Jan; Paluch-Lubawa, Ewelina; Spochacz, Marta; Rosiński, Grzegorz; Słocińska, Małgorzata

    2017-01-01

    Protective mechanisms against cold stress are well studied in terrestrial and polar insects; however, little is known about these mechanisms in tropical insects. In our study, we tested if a tropical cockroach Gromphadorhina coquereliana, possesses any protective mechanisms against cold stress. Based on the results of earlier studies, we examined how short-term (3 h) cold (4°C) influences biochemical parameters, mitochondrial respiration activity, and the level of HSPs and aquaporins expression in the fat body and leg muscles of G. coquereliana. Following cold exposure, we found that the level of carbohydrates, lipids and proteins did not change significantly. Nevertheless, we observed significant changes in mitochondrial respiration activity. The oxygen consumption of resting (state 4) and phosphorylating (state 3) mitochondria was altered following cold exposure. The increase in respiratory rate in state 4 respiration was observed in both tissues. In state 3, oxygen consumption by mitochondria in fat body was significantly lower compared to control insects, whereas there were no changes observed for mitochondria in muscle tissue. Moreover, there were cold-induced changes in UCP protein activity, but the changes in activity differed in fat body and in muscles. Additionally, we detected changes in the level of HSP70 and aquaporins expression. Insects treated with cold had significantly higher levels of HSP70 in fat body and muscles. On the other hand, there were lower levels of aquaporins in both tissues following exposure to cold. These results suggest that fat body play an important role in protecting tropical insects from cold stress.

  15. Study of exposure to cold stress and body physiological responses in auto mechanic employees in Hamadan city

    Directory of Open Access Journals (Sweden)

    Keivan Saedpanah

    2017-09-01

    Full Text Available Introduction: Continuous exposure to cold air is considered to be a hazardous agent in the workplace in cold seasons. This study aimed to determine the level of cold stress and relation with physiological responses in auto mechanic employees. Method: This cross-sectional study was conducted in the winter of 1395 on auto mechanic employees in Hamadan city. Physiological responses during daily activity were measured in accordance with ISO 9886 standard method. Environmental air measures like air temperature and air velocity were measured simultaneously and cold stress indexes were also determined. Data was analyzed using SPSS 21 software. Result: The result showed that mean wind chill index, equivalent chill temperature and required clothing insulation were 489.97±47.679 kcal/m2.h, 13.78± 1.869 0c and 2.04 ± 0.246 clo, respectively. According to the results of cold stress indexes, the studied employees are exposed to cold stress. Pearson correlation test showed that there are significant relationship between cold stress indexes with physiological responses (p<0.05, however, IREQ min showed more correlation than the others.  There is also a significant relationship between body fat percentage and deep temperature (p<0.05, r=0.314. Conclusion: The result confirmed that IREQ min index has high validity for estimation of cold stress among auto mechanic employees. Moreover, the increase of body fat percentage leads to an increase of cold tolerance power of employees.

  16. Corrosion behavior of cold-worked austenitic stainless steels in liquid lead-bismuth eutectic

    Science.gov (United States)

    Kurata, Yuji

    2014-05-01

    The effect of cold working on the corrosion behavior of austenitic stainless steels in liquid lead-bismuth eutectic (LBE) was studied to develop accelerator-driven systems for the transmutation of long-lived radioactive wastes and lead-bismuth cooled fast reactors. Corrosion tests on solution-treated, 20% cold-worked and 50% cold-worked 316SS and JPCA (15Cr-15Ni-Ti) were conducted in oxygen-controlled LBE. Slight ferritization caused by Ni dissolution and Pb-Bi penetration were observed for all specimens in the corrosion test conducted at 500 °C for 1000 h in liquid LBE with an intermediate oxygen concentration (1.4 × 10-7 wt.%). In the corrosion test performed at 550 °C for 1000 h in liquid LBE with a low oxygen concentration (4.2 × 10-9 wt.%), the depth of the ferritization of 316SS and JPCA increased with the extent of cold working. Only oxidation was observed in the corrosion test that was performed at 550 °C for 1000 h in liquid LBE with a high oxygen concentration (approximately 10-5 wt.%). Cold working accelerated the formation of the double layer oxide and increased the thickness of the oxide layer slightly. In contrast, the ferritization accompanied by Pb-Bi penetration was widely observed with oxidation for all specimens corrosion tested at 550 °C for 3000 h under the high-oxygen condition. Cold working increased the depth of the ferritization of 316SS and JPCA. It is considered that cold working accelerated the ferritization and Pb-Bi penetration through the enhanced dissolution of Ni into LBE due to an increase in the dislocation density under conditions in which the protective oxide layer was not formed in liquid LBE.

  17. Reactor Simulator Testing

    Science.gov (United States)

    Schoenfeld, Michael P.; Webster, Kenny L.; Pearson, Boise J.

    2013-01-01

    As part of the Nuclear Systems Office Fission Surface Power Technology Demonstration Unit (TDU) project, a reactor simulator test loop (RxSim) was design & built to perform integrated testing of the TDU components. In particular, the objectives of RxSim testing was to verify the operation of the core simulator, the instrumentation and control system, and the ground support gas and vacuum test equipment. In addition, it was decided to include a thermal test of a cold trap purification design and a pump performance test at pump voltages up to 150 V since the targeted mass flow rate of 1.75 kg/s was not obtained in the RxSim at the originally constrained voltage of 120 V. This paper summarizes RxSim testing. The gas and vacuum ground support test equipment performed effectively in NaK fill, loop pressurization, and NaK drain operations. The instrumentation and control system effectively controlled loop temperature and flow rates or pump voltage to targeted settings. The cold trap design was able to obtain the targeted cold temperature of 480 K. An outlet temperature of 636 K was obtained which was lower than the predicted 750 K but 156 K higher than the cold temperature indicating the design provided some heat regeneration. The annular linear induction pump (ALIP) tested was able to produce a maximum flow rate of 1.53 kg/s at 800 K when operated at 150 V and 53 Hz.

  18. Thermoregulation in peripheral nerve injury-induced cold-intolerant rats.

    Science.gov (United States)

    Duraku, L S; Smits, E S; Niehof, S P; Hovius, S E R; Walbeehm, E T; Selles, R W

    2012-06-01

    Cold intolerance is defined as pain after exposure to non-painful cold. It is suggested that cold intolerance may be related to dysfunctional thermoregulation in upper extremity nerve injury patients. The purpose of this study was to examine if the re-warming of a rat hind paw is altered in different peripheral nerve injury models and if these patterns are related to severity of cold intolerance. In the spared nerve injury (SNI) and complete sciatic lesion (CSL) model, the re-warming patterns after cold stress exposure were investigated preoperatively and at 3, 6 and 9 weeks postoperatively with a device to induce cooling of the hind paws. Thermocouples were attached on the dorsal side of the hind paw to monitor re-warming patterns. The Von Frey test and cold plate test indicated a significantly lower paw-withdrawal threshold and latency in the SNI compared to the Sham model. The CSL group, however, had only significantly lower paw-withdrawal latency on the cold plate test compared to the Sham group. While we found no significantly different re-warming patterns in the SNI and CSL group compared to Sham group, we did find a tendency in temperature increase in the CSL group 3 weeks postoperatively. Overall, our findings indicate that re-warming patterns are not altered after peripheral nerve injury in these rat models despite the fact that these animals did develop cold intolerance. This suggests that disturbed thermoregulation may not be the prime mechanism for cold intolerance and that, other, most likely, neurological mechanisms may play a more important role. There is no direct correlation between cold intolerance and re-warming patterns in different peripheral nerve injury rat models. This is an important finding for future developing treatments for this common problem, since treatment focussing on vaso-regulation may not help diminish symptoms of cold-intolerant patients. Copyright © 2011 British Association of Plastic, Reconstructive and Aesthetic Surgeons

  19. Cold-War Echoes in American Children.

    Science.gov (United States)

    Winn, Ira Jay

    1984-01-01

    The author believes a cold war ideology permeates our culture and poisons the minds of youth. The challenge to education is to awaken people to a historical and global perspective and raise public consciousness of the necessity for peace. (MD)

  20. Cold, Ice, and Snow Safety (For Parents)

    Science.gov (United States)

    ... sports out there for the entire family — sledding , snowboarding , and skiing to mention a few. Plus, someone has to ... because cold-weather activities like ice-skating, sledding, snowboarding, and skiing can lead to accidents that often ...

  1. Tonsillectomy: Vasoconstrictive hydrolytic cold dissection method ...

    African Journals Online (AJOL)

    : Surgeons used to other techniques of tonsillectomies may not revert to the cold steel; however, those practicing CSM will benefi t from VHCD. We hereby ... Key words: Normal saline, tonsillectomy, vasoconstrictive hydrolytic dissection ...

  2. Soap Bubbles on a Cold Day.

    Science.gov (United States)

    Waiveris, Charles

    1994-01-01

    Discusses the effects of blowing bubbles in extremely cold weather. Describes the freezing conditions of the bubbles and some physical properties. Suggests using the activity with all ages of students. (MVL)

  3. Atomic physics: Cold gases venture into Flatland

    Science.gov (United States)

    Burnett, Keith

    2007-09-01

    Vortex structures have revealed a lot about the nature of three-dimensional Bose-Einstein condensates. They play an even bigger part in two-dimensional cold atomic gases and drive a fundamentally different phase transition.

  4. Caring for Your Child's Cold or Flu

    Science.gov (United States)

    ... Print Share Caring for Your Child’s Cold or Flu Page Content ​Unfortunately, there's no cure for the ... Liquid Medicine Safely for more information.​ Prevention & Treatment: Flu vaccine Children 6 months or older should get ...

  5. Cold quark matter in compact stars

    Energy Technology Data Exchange (ETDEWEB)

    Franzon, B.; Fogaca, D. A.; Navarra, F. S. [Instituto de Fisica, Universidade de Sao Paulo Rua do Matao, Travessa R, 187, 05508-090 Sao Paulo, SP (Brazil); Horvath, J. E. [Instituto de Astronomia, Geofisica e Ciencias Atmosfericas, Universidade de Sao Paulo, Rua do Matao, 1226, 05508-090, Sao Paulo, SP (Brazil)

    2013-03-25

    We used an equation of state for the cold quark matter to the study of properties of quark stars. We also discuss the absolute stability of quark matter and compute the mass-radius relation for self-bound stars.

  6. Cold vacuum drying facility design requirements

    Energy Technology Data Exchange (ETDEWEB)

    Irwin, J.J.

    1997-09-24

    This release of the Design Requirements Document is a complete restructuring and rewrite to the document previously prepared and released for project W-441 to record the design basis for the design of the Cold Vacuum Drying Facility.

  7. Sustainable construction in remote cold regions.

    Science.gov (United States)

    2015-12-01

    The goal of this project was to identify sustainable construction techniques appropriate for remote and cold regions, some of which apply to : operations and maintenance as well. The vast body of literature regarding green construction in warm region...

  8. Cold Medicines for Kids: What's the Risk?

    Science.gov (United States)

    ... uptodate.com/contents/search. Accessed Oct. 18, 2017. Green JL, et al. Safety profile of cough and ... 2017 Original article: http://www.mayoclinic.org/healthy-lifestyle/childrens-health/in-depth/cold-medicines/art-20047855 . ...

  9. Sizing Post-Cold War Nuclear Forces

    National Research Council Canada - National Science Library

    Oelrich, I

    2001-01-01

    This study addresses the utility of, and need for, nuclear weapons a decade after the end of the Cold War with special focus on the numbers and types of nuclear weapons appropriate for particular requirements...

  10. Warm and cold complex regional pain syndromes: differences beyond skin temperature?

    Science.gov (United States)

    Eberle, T; Doganci, B; Krämer, H H; Geber, C; Fechir, M; Magerl, W; Birklein, F

    2009-02-10

    To investigate clinical differences in warm and cold complex regional pain syndrome (CRPS) phenotypes. CRPS represents inhomogeneous chronic pain conditions; approximately 70% patients with CRPS have "warm" affected limbs and 30% have "cold" affected limbs. We examined 50 patients with "cold" and "warm" CRPS (n = 25 in each group). Both groups were matched regarding age, sex, affected limb, duration of CRPS, and CRPS I and II to assure comparability. Detailed medical history and neurologic status were assessed. Moreover, quantitative sensory testing (QST) was performed on the affected ipsilateral and clinically unaffected contralateral limbs. Compared with patients who had warm CRPS, patients who had cold CRPS more often reported a history of serious life events (p CRPS, the incidence of CRPS-related dystonia was increased (p CRPS (p CRPS were characterized by mechanical hyperalgesia (p CRPS) are associated with different clinical findings, beyond skin temperature changes. This might have implications for the understanding of CRPS pathophysiology.

  11. Turbine Research Program Cold Weather Turbine Project: Period of Performance May 27, 1999 -- March 31, 2004

    Energy Technology Data Exchange (ETDEWEB)

    Lynch, J.; Bywaters, G.; Costin, D.; Hoskins, S.; Mattila, P.; Stowell, J.

    2004-08-01

    Northern Power Systems completed the Cold Weather Turbine (CWT) project, which was funded by the National Renewable Energy Laboratory (NREL), under subcontract XAT-9-29200-01. The project's primary goal is to develop a 100-kW wind turbine suited for deployment in remote villages in cold regions. The contract required testing and certification of the turbine to the International Electrotechnical Commission (IEC) 61400-1 international standard through Underwriters Laboratories (UL). The contract also required Northern Power Systems to study design considerations for operation in extreme cold (-80F at the South Pole, for example). The design was based on the successful proof of concept (POC) turbine (developed under NREL and NASA contracts), considered the prototype turbine that would be refined and manufactured to serve villages in cold regions around the world.

  12. Three-stage linear, split-Stirling cryocooler for 1 to 2K magnetic cold stage

    Science.gov (United States)

    Longsworth, R. C.

    1993-08-01

    A long-life, linear, high efficiency 8K split Stirling cycle cryocooler was designed, built, and tested. The refrigerator is designed for cooling a 50 mW, 1.5K magnetic cold stage. Dual opposed piston compressors are driven by moving-coil linear motors. The three stage expander, although not completed, is also driven by a linear motor and is designed to produce 1 SW at 60K, 4W at 16K, and 1.2W at 8K. The cold regenerator employs a parallel gap construction for high efficiency. The key technology areas addressed include warm and cold flexible suspension bearings and a new cold regenerator geometry for high efficiency at 8K.

  13. Cold-induced urticaria with a familial transmission: a case report and review of the literature

    Directory of Open Access Journals (Sweden)

    Furr Joe C

    2012-02-01

    Full Text Available Abstract Introduction Cryopyrin-associated periodic syndrome is a rare genetic disorder causing cold-induced urticaria, severe arthralgias, and (potentially renal failure and hearing loss. Therapies that effectively control the symptoms and prevent the complications of this debilitating disorder are now available, making recognition of this disease important. Case presentation A 60-year-old Caucasian woman presented with complaints of rash and joint pains to a general medicine clinic. Her history showed that her symptoms were linked to cold exposure, but the results of a cold stimulation time test were negative. Several generations of her family had similar symptoms. Conclusions This case highlights the importance of considering cryopyrin-associated periodic syndrome in the differential diagnosis of cold-induced urticaria. Several medications targeting interleukin-1-beta are available, providing significant relief from symptoms and improvement in quality of life in affected patients.

  14. Dimensional ranges and rolling efficiency in a tandem cold rolling mill

    Energy Technology Data Exchange (ETDEWEB)

    Larkiola, J.

    1997-12-31

    In this work, physical models and a neural network theory have been combined in order to predict the properties of a steel strip and to optimise the process parameters in cold rolling. The prediction of the deformation resistance of the material and the friction parameter is based on the physical model presented by Bland, Ford and Ellis and artificial neural network computing (ANN). The accuracy of these models has been tested and proved by using a large amount of the measured data. With the aid of these models it has been shown that (a) the small change to the relative reduction distribution can have a clear effect upon the rolling efficiency, (b) the dimensional ranges of the tandem cold roll mill can be determined and optimised and (c) the possibility to cold roll a new product of new width, strength or thickness can be determined and the parameters of the tandem cold rolling process can be optimised. (orig.) 43 refs.

  15. Acute cold exposure and rewarming enhanced spatial memory and activated the MAPK cascades in the rat brain.

    Science.gov (United States)

    Zheng, Gang; Chen, Yaoming; Zhang, Xueping; Cai, Tongjian; Liu, Mingchao; Zhao, Fang; Luo, Wenjing; Chen, Jingyuan

    2008-11-06

    Cold is a common stressor that is likely to occur in everyday occupational or leisure time activities. Although there is substantial literature on the effects of stress on memory from behavioral and pharmacologic perspectives, the effects of cold stress on learning and memory were little addressed. The aims of the present work were to investigate the effects of acute cold exposure on Y-maze learning and the activation of cerebral MAPK cascades of rats. We found that the 2-hour cold exposure (-15 degrees C) and a subsequent 30-min rewarming significantly increased the performance of the rats in the Y-maze test. Serum corticosterone (CORT) level was increased after the cold exposure. After a transient reduction following the cold exposure, the P-ERK levels in the hippocampus and PFC drastically increased 30 min later. The levels of P-JNK increased gradually after the cold exposure in all the three brain regions we investigated, but the level of P-p38 only increased in the PFC. The levels of GABAA receptor alpha1 subunit remained unchanged after the cold exposure. Furthermore, the performance of rats treated with cold plus muscimol or bicuculline in the Y-maze test was similar to that of the rats treated with those GABAergic agents alone. These results demonstrated that acute cold exposure and the subsequent rewarming could result in enhanced performance of spatial learning and memory, and the activation of MAPKs in the brain. However, GABAA receptor may not be involved in the acute cold exposure-induced enhancement of memory.

  16. Assessment of Cold Stress and Its Effects on Workers in a Cold-Storage Warehouse

    OpenAIRE

    Farhang Akbar-Khanzadeh; Mohammad–Hossein Sajadi; Keramat Nouri Jelyani; Farideh Golbabaei

    2009-01-01

    Exposure to cold work environment is an occupational health hazard and poses adverse effect on workers health, performance and productivity. This study was performed in a cold food-storage warehouse complex in Tehran-Iran in order to evaluate the workers' exposure to cold stress. Twenty nine exposed workers and 33 non-exposed workers as control subject were included in this study. Climatic factors were measured based on ISO 7996 at the three levels of workers height. Physiological factor...

  17. Signal transduction during cold stress in plants

    OpenAIRE

    Solanke, Amolkumar U.; Sharma, Arun K.

    2008-01-01

    Cold stress signal transduction is a complex process. Many physiological changes like tissue break down and senescence occur due to cold stress. Low temperature is initially perceived by plasma membrane either due to change in membrane fluidity or with the help of sensors like Ca2+ permeable channels, histidine kinases, receptor kinases and phospholipases. Subsequently, cytoskeleton reorganization and cytosolic Ca2+ influx takes place. Increase in cytosolic Ca2+ is sensed by CDPKs, phosphatas...

  18. Toxicity evaluation and hazard review Cold Smoke

    Energy Technology Data Exchange (ETDEWEB)

    Archuleta, M.M.; Stocum, W.E.

    1993-12-01

    Cold Smoke is a dense white smoke produced by the reaction of titanium tetrachloride and aqueous ammonia aerosols. Early studies on the toxicity of this nonpyrotechnically generated smoke indicated that the smoke itself is essentially non-toxic (i.e. exhibits to systemic toxicity or organ damage due to exposure) under normal deployment conditions. The purpose of this evaluation was to review and summarize the recent literature data available on the toxicity of Cold Smoke, its chemical constituents, and its starting materials.

  19. Control of the 133 cesium cold collisions, search for a variation of the fine structure constant using a dual rubidium-cesium atomic fountain; Controle des collisions froides du cesium {sup 133}Cs: tests de la variation de la constante de structure fine a l'aide d'une fontaine atomique double rubidium-cesium

    Energy Technology Data Exchange (ETDEWEB)

    Marion, H

    2005-03-15

    We developed a method of measurement of the frequency shift due to the collisions between cold atoms. This is the main systematic limitation for the accuracy of the Cs{sup 133} based fountains ({approx} 10{sup -15} in relative frequency). Consequently, we can measure this effect near 0.5% This opens prospects for improvements of the fountains performances in term of accuracy until 10{sup -16}. The fountain has also obtained a stability about 10{sup -14} at 1 s. We discovered for the first time, at very low magnetic field (5 {+-} 1 mG), Feshbach resonances. We also took a new absolute measurement of the hyperfine transition of the Rb{sup 87}, which is the most precise ever carried out and is used now as definition for the secondary standard. By comparing this value with those measured the previous years, we could carry out a test of the stability of the fine structure constant on the level of 10{sup -15} /yr. We led local comparisons between atomic fountains and the other fountains of the laboratory. Most stable it is unrolled with a combined stability of 5.10{sup -14} at 1 s. The behavior of the difference of the two clocks goes like white frequency noise up to 3.10{sup -16}. The assessment of the dual fountain accuracy budget has been evaluated at 7.10{sup -16} for the cesium part and 8.10{sup -16} for the rubidium part. We contributed to the realization of the scale of International Atomic Time, by series of calibrations of hydrogen masers. An atomic comparison of fountain by satellite links was tested between our laboratory and our German counterpart. This measurement has determined the good agreement between the two clocks. (author)

  20. Lessons from history: morbidity of cold injury in the Royal Marines during the Falklands Conflict of 1982.

    Science.gov (United States)

    Golden, Francis St Clair; Francis, Thomas James Roose; Gallimore, Deborah; Pethybridge, Roger

    2013-08-08

    Environmental conditions in the Falklands Conflict of 1982 favoured the genesis of cold injuries. Immediately, post-war, cold injury morbidity and its contributory factors were assessed, in the personnel of UK 3 Commando Brigade (3 Cdo Bde). A questionnaire survey of the 3,006 members of 3 Cdo Bde who landed on the islands was conducted within 6-10 weeks of the end of hostilities. Questions included those relating to features of cold injury, body morphology, age, symptoms experienced, past medical history and other possible contributory causes. Additionally, the unit medical team conducted a cursory examination. Data were sent to the Royal Navy Institute of Naval Medicine (INM), where the degree of likely cold injury was broadly classified ('asymptomatic' 'mild', 'moderate' or 'severe'). A sample (total 109) was then selected at random from each category and subsequently examined and tested at the INM (nerve conduction, photoplethysmography and thermography testing). Forty-seven non-cold exposed sailors acted as a control group. These contemporaneous records have now been identified and interrogated. Some 2,354 (78%) completed questionnaires were returned, revealing that 1,505 (64%) had experienced symptoms of non-freezing cold injury. The morbidity in the infantry units was significantly greater than that in the support troops (1,051 (76%) vs 454 (46%), p cold injury. Whilst there was no significant relationship between past history and cold injury morbidity in the brigade as a whole, or within the infantry units alone, an association was identified in the collective infantry units (73%) and the support/headquarter units (59%) (p after returning to the UK, while the photoplethysmography and thermographic responses to a cold sensitivity test showed that most (including those classed by questionnaire as asymptomatic) had residual 'cold sensitivity'. Although the passage of time has made retrospective interrogation of historical documents hard, the available data