WorldWideScience

Sample records for cold air outbreaks

  1. Persistent cold air outbreaks over North America in a warming climate

    International Nuclear Information System (INIS)

    Gao, Yang; Leung, L Ruby; Lu, Jian; Masato, Giacomo

    2015-01-01

    This study examines future changes of cold air outbreaks (CAOs) using a multi-model ensemble of global climate simulations from the Coupled Model Intercomparison Project Phase 5 and high resolution regional climate simulations. Overall, climate models agree on a dip in CAO duration across North America, but the percentage change is consistently smaller from western Canada to the upper mid-western US with historically more frequent CAO. By decomposing the changes of the probability density function of daily surface temperature into changes due to mean warming and changes in standard deviation (std) and skewness/higher order moments, the contributions of each factor to CAO changes are quantified. Results show that CAO changes can be explained largely by the mean warming, but the decrease in temperature std contributes to about 20% reduction of CAO from Alaska to northeastern US and eastern Canada possibly due to the Arctic amplification and weakening of storm track. A thermodynamical modulation of the skewness called the ‘0 °C mode’ effect is found to operate prominently along the 0 °C isotherm hemispherically and reduce CAO in western and northeastern US with winter snow cover by up to 10%. This effect also produces a manifold increase in CAO events over the Arctic sea ice. An increased frequency in atmospheric blocking also contributes to increases in CAO duration over Alaska and the Arctic region. Regional simulations revealed more contributions of existing snowpack to CAO in the near future over the Rocky Mountain, southwestern US, and Great Lakes areas through surface albedo effects. Overall, the multi-model projections emphasize that cold extremes do not completely disappear in a warming climate. Concomitant with the relatively smaller reduction in CAO events in northwestern US, the top five most extreme CAO events may still occur, and wind chill will continue to have societal impacts in that region. (letter)

  2. The Characteristics of Cold Air Outbreaks in the Eastern United States and the Influence of Atmospheric Circulation Patterns

    Science.gov (United States)

    Smith, E. T.

    2017-12-01

    Periods of extreme cold impact the mid-latitudes every winter. Depending on the magnitude and duration of the occurrence, extremely cold periods may be deemed cold air outbreaks (CAOs). Atmospheric teleconnections impact the displacement of polar air, but the relationship between the primary teleconnections and the manifestation of CAOs is not fully understood. A systematic CAO index was developed from 20 surface weather stations based on a set of criteria concerning magnitude, duration, and spatial extent. Statistical analyses of the data were used to determine the overall trends in CAOs. Clusters of sea level pressure (SLP), 100mb, and 10mb geopotential height anomalies were mapped utilizing self-organizing maps (SOMs) to understand the surface, upper-tropospheric Polar Vortex (PV), and stratospheric PV patterns preceding CAOs. The Arctic Oscillation (AO), North Atlantic Oscillation (NAO), and Pacific-North American (PNA) teleconnections were used as variables to explain the magnitude and location of mid-latitude Arctic air displacement. Persistently negative SLP anomalies across the Arctic and North Atlantic were evident 1 - 2 weeks prior to the CAOs throughout the winter. The upper-tropospheric and stratospheric PV were found to be persistently weak/weakening prior to mid-winter CAOs and predominantly strong and off-centered prior to early and late season CAOs. Negative phases of the AO and NAO were favored prior to CAOs, while the PNA favored a near-neutral phase. This method of CAO and synoptic pattern characterization benefits from a continuous pattern representation and provides insight as to how specific teleconnections impact the atmospheric flow in a way that leads to CAOs in the eastern U.S.

  3. The "Grey Zone" cold air outbreak global model intercomparison: A cross evaluation using large-eddy simulations

    Science.gov (United States)

    Tomassini, Lorenzo; Field, Paul R.; Honnert, Rachel; Malardel, Sylvie; McTaggart-Cowan, Ron; Saitou, Kei; Noda, Akira T.; Seifert, Axel

    2017-03-01

    A stratocumulus-to-cumulus transition as observed in a cold air outbreak over the North Atlantic Ocean is compared in global climate and numerical weather prediction models and a large-eddy simulation model as part of the Working Group on Numerical Experimentation "Grey Zone" project. The focus of the project is to investigate to what degree current convection and boundary layer parameterizations behave in a scale-adaptive manner in situations where the model resolution approaches the scale of convection. Global model simulations were performed at a wide range of resolutions, with convective parameterizations turned on and off. The models successfully simulate the transition between the observed boundary layer structures, from a well-mixed stratocumulus to a deeper, partly decoupled cumulus boundary layer. There are indications that surface fluxes are generally underestimated. The amount of both cloud liquid water and cloud ice, and likely precipitation, are under-predicted, suggesting deficiencies in the strength of vertical mixing in shear-dominated boundary layers. But also regulation by precipitation and mixed-phase cloud microphysical processes play an important role in the case. With convection parameterizations switched on, the profiles of atmospheric liquid water and cloud ice are essentially resolution-insensitive. This, however, does not imply that convection parameterizations are scale-aware. Even at the highest resolutions considered here, simulations with convective parameterizations do not converge toward the results of convection-off experiments. Convection and boundary layer parameterizations strongly interact, suggesting the need for a unified treatment of convective and turbulent mixing when addressing scale-adaptivity.

  4. A comparison of ground and satellite observations of cloud cover to saturation pressure differences during a cold air outbreak

    Energy Technology Data Exchange (ETDEWEB)

    Alliss, R.J.; Raman, S. [North Carolina State Univ., Raleigh, NC (United States)

    1996-04-01

    The role of clouds in the atmospheric general circulation and the global climate is twofold. First, clouds owe their origin to large-scale dynamical forcing, radiative cooling in the atmosphere, and turbulent transfer at the surface. In addition, they provide one of the most important mechanisms for the vertical redistribution of momentum and sensible and latent heat for the large scale, and they influence the coupling between the atmosphere and the surface as well as the radiative and dynamical-hydrological balance. In existing diagnostic cloudiness parameterization schemes, relative humidity is the most frequently used variable for estimating total cloud amount or stratiform cloud amount. However, the prediction of relative humidity in general circulation models (GCMs) is usually poor. Even for the most comprehensive GCMs, the predicted relative humidity may deviate greatly from that observed, as far as the frequency distribution of relative humidity is concerned. Recently, there has been an increased effort to improve the representation of clouds and cloud-radiation feedback in GCMs, but the verification of cloudiness parameterization schemes remains a severe problem because of the lack of observational data sets. In this study, saturation pressure differences (as opposed to relative humidity) and satellite-derived cloud heights and amounts are compared with ground determinations of cloud cover over the Gulf Stream Locale (GSL) during a cold air outbreak.

  5. Using cold air for reducing needle-injection pain.

    Science.gov (United States)

    Al-Qarqaz, Firas; Al-Aboosi, Mustafa; Al-shiyab, Diala; Al Dabbagh, Ziad

    2012-07-01

    Pain is associated with skin injections. Reducing injection-associated pain is important especially when multiple injections are needed in difficult areas, such as the palms. We present a new safe application for cold air used in laser therapy. The main objectives of this study are to see whether cold air can reduce needle-injection pain and to evaluate the safety of this new application. Patients undergoing skin injection (n=40) were included. Assessment of pain level using visual analog scale (VAS) was done using cold air and again without cold air in the same patient. Comparison of pain scores was performed. Thirty-three patients had lower VAS scores using cold air. Five patients had worse VAS scores, and two patients did not have any change in their pain score. In the group of patients where injections were made to the palms (n=5), there was even more reduction in VAS scores. There were no significant immediate or delayed side effects. Cold air seems to be useful in reducing needle-injection pain in the majority of patients, especially in the palms. This procedure is safe, apart from immediate tolerable discomfort when used around the nose. © 2012 The International Society of Dermatology.

  6. Cold Outbreaks at the Mesoscale in the Western Mediterranean Basin: From Raincells to Rainbands

    Directory of Open Access Journals (Sweden)

    Jordi Mazon

    2017-01-01

    Full Text Available This paper investigates cold outbreaks that form offshore density currents within the whole mesoscale over the Western Mediterranean basin. Reflectivity radar and satellite images are used to detect clouds and precipitation that are associated with these density currents in the meso-α, meso-β, and meso-γ over the Western Mediterranean basin (WMB. Version 3.3 of the WRF-ARW model is used to describe the formation and evolution of these density currents and to estimate their lifetime as well as horizontal and vertical scales. Based on the observations and simulations, this paper suggests that a new perspective could effectively be adopted regarding the WMB region delineated by the Balearic Islands, the northeastern Iberian Peninsula, and the Gulf of Lion, where inland cold outbreaks develop into density currents that move offshore and can produce precipitation ranging from raincells to rainbands at the whole mesoscale.

  7. Dengue Virus 1 Outbreak in Buenos Aires, Argentina, 2016.

    Science.gov (United States)

    Tittarelli, Estefanía; Lusso, Silvina B; Goya, Stephanie; Rojo, Gabriel L; Natale, Mónica I; Viegas, Mariana; Mistchenko, Alicia S; Valinotto, Laura E

    2017-10-01

    The largest outbreak of dengue in Buenos Aires, Argentina, occurred during 2016. Phylogenetic, phylodynamic, and phylogeographic analyses of 82 samples from dengue patients revealed co-circulation of 2 genotype V dengue virus lineages, suggesting that this virus has become endemic to the Buenos Aires metropolitan area.

  8. Synoptic climatology, and intrahemispheric associations, of cold air mesocyclones in the Australasian sector

    Science.gov (United States)

    Carleton, Andrew M.; Song, Yudong

    1997-06-01

    Satellite IR images for seven months in 1992 are interpreted for cold air mesoscale cyclones (mesocyclones) occurring in the Australasian sector (˜70°E-150°W) of the Southern Ocean. Time-averaged (monthly, seasonal) distributions of mesocyclogenesis, mesocyclolysis, and tracks of movement, along with statistical summaries of mesocyclone attributes (e.g., cloud vortex size, speeds of movement), are presented and discussed in the context of the larger-scale atmospheric circulation. Maximum frequencies of mesocyclones occurred in the transitional months of April and October 1992, with a secondary peak in July. Statistically significant differences in mesocyclone track length between months appear related dominantly to changes in speed of the background flow, associated with the semiannual oscillation (SAO) of tropospheric pressure/height. The associations of mesocyclone "outbreaks" with composite anomaly fields of pressure and height are identified for three subareas of the Australasian sector suggested by the analysis of mesocyclone spatial patterns. Outbreaks occur in the strong southerly geostrophic airflow located between pressure and height anomalies that are negative (positive) to the eastward (westward). When outbreaks occurred in the New Zealand subarea in 1992, a similarly strong couplet of pressure/height anomalies developed in the southern South America/Antarctic Peninsula sector but not when outbreaks occurred south of Australia. The mesocyclone remote association that is suggested is evaluated by using polar orbiter IR imagery for the southeastern Pacific region. Frequencies of mesocyclones increase (decrease) west of Chile but decrease (increase) through Drake Passage when mesocyclone outbreaks occur near New Zealand (south of Australia). These long distance associations of mesocyclone outbreaks are consistent with the connectivity of the baroclinic waves and might prove useful in the development of techniques to forecast mesocyclones over the

  9. Heated air humidification versus cold air nebulization in newly tracheostomized patients.

    Science.gov (United States)

    Birk, Richard; Händel, Alexander; Wenzel, Angela; Kramer, Benedikt; Aderhold, Christoph; Hörmann, Karl; Stuck, Boris A; Sommer, J Ulrich

    2017-12-01

    After tracheostomy, the airway lacks an essential mechanism for warming and humidifying the inspired air with the consequent functional impairment and discomfort. The purpose of this study was to compare airway hydration with cold-air nebulization versus heated high-flow humidification on medical interventions and tracheal ciliary beat frequency (CBF). Newly tracheostomized patients (n = 20) were treated either with cold-air nebulization or heated humidification. The number of required tracheal suctioning procedures to clean the trachea and tracheal CBF were assessed. The number of required suctions per day was significantly lower in the heated humidification group with medians 3 versus 5 times per day. Mean CBF was significantly higher in the heated humidification group (6.36 ± 1.49 Hz) compared to the cold-air nebulization group (3.99 ± 1.39 Hz). The data suggest that heated humidification enhanced mucociliary transport leading to a reduced number of required suctioning procedures in the trachea, which may improve postoperative patient care. © 2017 The Authors Head & Neck Published by Wiley Periodicals, Inc.

  10. Modeling a cold-air drainage event with a wireless sensor network

    OpenAIRE

    Brian R. Zutta; Eric A. Graham; Philip W. Rundel

    2005-01-01

    A wireless network of sensors was used to characterize a cold-air drainage event in the canyon surrounding the James Reserve. The flow of cold air at night and the first hours of sunrise have major ecological consequences by limiting the vegetation types to those tolerant of freeze and thaw cycles. A network of wireless sensors provides the opportunity to track this event in real time and fully characterize the cold air flow down the canyon, which may last 1.5 hours, and the pooling of cold a...

  11. Cold-inducible RNA-binding protein mediates cold air inducible airway mucin production through TLR4/NF-κB signaling pathway.

    Science.gov (United States)

    Chen, Lingxiu; Ran, Danhua; Xie, Wenyue; Xu, Qing; Zhou, Xiangdong

    2016-10-01

    Mucus overproduction is an important feature in patients with chronic inflammatory airway diseases and cold air stimulation has been shown to be associated with the severity of these diseases. However, the regulatory mechanisms that mediate excessive mucin production under cold stress remain elusive. Recently, the cold-inducible RNA-binding protein (CIRP) has been shown to be markedly induced after exposure to cold air. In this study, we sought to explore the expression of CIRP within bronchial biopsy specimens, the effect on mucin5AC (MUC5AC) production in chronic inflammatory airway diseases and the potential signaling pathways involved in cold air stimulation process. We found that CIRP protein expression was significantly increased in patients with COPD and in mice treated with cold air. Moreover, cold air stimulation induced MUC5AC expression in wild-type mice but not in CIRP(-/-) mice. In vitro, cold air stress significantly elevated the transcriptional and protein expression levels of MUC5AC in human bronchial epithelial cells. CIRP, toll-like receptor 4 (TLR4) and phosphorylated NF-κB p65 (p-p65) increased significantly in response to cold stress and CIRP siRNA, TLR4 - neutralizing Ab and a specific inhibitor of NF-κB could attenuated cold stress inducible MUC5AC expression. In addition, CIRP siRNA could hindered the expression levels of TLR4 and p-p65 both induced by cold stress. Taken together, these results suggest that airway epithelial cells constitutively express CIRP in vitro and in vivo. CIRP is responsible for cold-inducible MUC5AC expression by activating TLR4/NF-κB signaling pathway. Copyright © 2016 Elsevier B.V. All rights reserved.

  12. Winter sports athletes: long-term effects of cold air exposure.

    Science.gov (United States)

    Sue-Chu, Malcolm

    2012-05-01

    Athletes such as skaters and skiers inhale large volumes of cold air during exercise and shift from nasal to mouth breathing. Endurance athletes, like cross-country skiers, perform at 80% or more of their maximal oxygen consumption and have minute ventilations in excess of 100 l/min. Cold air is always dry, and endurance exercise results in loss of water and heat from the lower respiratory tract. In addition, athletes can be exposed to indoor and outdoor pollutants during the competitive season and during all-year training. Hyperpnoea with cold dry air represents a significant environmental stress to the airways. Winter athletes have a high prevalence of respiratory symptoms and airway hyper-responsiveness to methacholine and hyperpnoea. The acute effects of exercise in cold air are neutrophil influx as demonstrated in lavage fluid and airway epithelial damage as demonstrated by bronchoscopy. Upregulation of pro-inflammatory cytokines has been observed in horses. Chronic endurance training damages the epithelium of the small airways in mice. Airway inflammation has been observed on bronchoscopy of cross-country skiers and in dogs after a 1100-mile endurance race in Alaska. Neutrophilic and lymphocytic inflammation with remodelling is present in bronchial biopsies from skiers. Repeated peripheral airway hyperpnoea with dry air causes inflammation and remodelling in dogs. As it is currently unknown if these airway changes are reversible upon cessation of exposure, preventive measures to diminish exposure of the lower airways to cold air should be instituted by all winter sports athletes.

  13. Cold Vacuum Drying Instrument Air System Design Description. System 12

    International Nuclear Information System (INIS)

    SHAPLEY, B.J.; TRAN, Y.S.

    2000-01-01

    This system design description (SDD) addresses the instrument air (IA) system of the spent nuclear fuel (SNF). This IA system provides instrument quality air to the Cold Vacuum Drying (CVD) Facility. The IA system is a general service system that supports the operation of the heating, ventilation, and air conditioning (HVAC) system, the process equipment skids, and process instruments in the CVD Facility. The following discussion is limited to the compressor, dryer, piping, and valving that provide the IA as shown in Drawings H-1-82222, Cold Vacuum Drying Facility Mechanical Utilities Compressed and Instrument Air PandID, and H-1.82161, Cold Vacuum Drying Facility Process Equipment Skid PandID MCO/Cusk Interface. Figure 1-1 shows the physical location of the 1A system in the CVD Facility

  14. Cold Vacuum Drying Instrument Air System Design Description (SYS 12)

    Energy Technology Data Exchange (ETDEWEB)

    SHAPLEY, B.J.; TRAN, Y.S.

    2000-06-05

    This system design description (SDD) addresses the instrument air (IA) system of the spent nuclear fuel (SNF). This IA system provides instrument quality air to the Cold Vacuum Drying (CVD) Facility. The IA system is a general service system that supports the operation of the heating, ventilation, and air conditioning (HVAC) system, the process equipment skids, and process instruments in the CVD Facility. The following discussion is limited to the compressor, dryer, piping, and valving that provide the IA as shown in Drawings H-1-82222, Cold Vacuum Drying Facility Mechanical Utilities Compressed & Instrument Air P&ID, and H-1.82161, Cold Vacuum Drying Facility Process Equipment Skid P&ID MCO/Cusk Interface. Figure 1-1 shows the physical location of the 1A system in the CVD Facility.

  15. Outbreaks associated to large open air festivals, including music festivals, 1980 to 2012.

    Science.gov (United States)

    Botelho-Nevers, E; Gautret, P

    2013-03-14

    In the minds of many, large scale open air festivals have become associated with spring and summer, attracting many people, and in the case of music festivals, thousands of music fans. These festivals share the usual health risks associated with large mass gatherings, including transmission of communicable diseases and risk of outbreaks. Large scale open air festivals have however specific characteristics, including outdoor settings, on-site housing and food supply and the generally young age of the participants. Outbreaks at large scale open air festivals have been caused by Cryptosporium parvum, Campylobacter spp., Escherichia coli, Salmonella enterica, Shigella sonnei, Staphylococcus aureus, hepatitis A virus, influenza virus, measles virus, mumps virus and norovirus. Faecal-oral and respiratory transmissions of pathogens result from non-compliance with hygiene rules, inadequate sanitation and insufficient vaccination coverage. Sexual transmission of infectious diseases may also occur and is likely to be underestimated and underreported. Enhanced surveillance during and after festivals is essential. Preventive measures such as immunisations of participants and advice on-site and via social networks should be considered to reduce outbreaks at these large scale open air festivals.

  16. A closer look at the relationships between meridional mass circulation pulses in the stratosphere and cold air outbreak patterns in northern hemispheric winter

    Science.gov (United States)

    Yu, Yueyue; Cai, Ming; Ren, Rongcai; Rao, Jian

    2018-01-01

    The relationship between continental-scale cold air outbreaks (CAOs) in the mid-latitudes and pulse signals in the stratospheric mass circulation in Northern Hemisphere winter (December-February) is investigated using ERA-Interim data for the 32 winters from 1979 to 2011. Pulse signals in the stratospheric mass circulation include "PULSE_TOT", "PULSE_W1", and "PULSE_W2" events, defined as a period of stronger meridional mass transport into the polar stratosphere by total flow, wavenumber-1, and wavenumber-2, respectively. Each type of PULSE event occurs on average 4-6 times per winter. A robust relationship is found between two dominant patterns of winter CAOs and PULSE_W1 and PULSE_W2 events. Cold temperature anomalies tend to occur over Eurasia with the other continent anomalously warm during the 2 weeks before the peak dates of PULSE_W1 events, while the opposite temperature anomaly pattern can be found after the peak dates; and during the 1-2 weeks centered on the peak dates of PULSE_W2 events, a higher probability of occurrence of CAOs is found over both continents. These relationships become more robust for PULSE_W1 and PULSE_W2 events of larger peak intensity. PULSE_TOT events are classified into five types, which have a distinct coupling relationship with PULSE_W1 and PULSE_W2 events. The specific pattern of CAOs associated with each type of PULSE_TOT event is found to be a combination of the CAO patterns associated with PULSE_W1 and PULSE_W2 events. The percentage of PULSE_TOT events belonging to the types that are dominated by PULSE_W2 events increases with the peak intensity of PULSE_TOT events. Accordingly, the related CAO pattern is close to that associated with PULSE_W1 for PULSE_TOT events with small-to-medium intensity, but tends to resemble that associated with PULSE_W2 events as the peak intensity of PULSE_TOT events increases.

  17. The structure and energetics of midlatitude disturbances accompanying cold-air outbreaks over East Asia

    Science.gov (United States)

    Lau, N.-C.; Lau, K.-M.

    1984-01-01

    The evolution of extratropical transient waves as they propagate eastward from the Eurasian land mass toward the Pacific during selected cold surge events in the winter Monsoon Experiment (MONEX) is studied. The outstanding cold surge episodes during MONEX are first identified, and the salient synoptic features related to these events are described using composite streamline charts. The structure of rapidly varying disturbances accompanying the cold surges and the associated energetics are examined, and the behavior of those fluctuations over relatively longer time scales is addressed.

  18. New options for the cold storage air curtain in the food sector; Koelruimte-luchtgordijn biedt nieuwe mogelijkheden

    Energy Technology Data Exchange (ETDEWEB)

    Bruins, K. [Biddle, Kootstertille (Netherlands)

    1997-10-01

    Based on a newly developed so-called multi air jet technology air curtains in front of cold spaces prevent warm air from infiltrating the cold space. The principles and performance of the cold space air curtain are briefly outlined. 2 figs.

  19. Spatial and temporal association of outbreaks of H5N1 influenza virus infection in wild birds with the 0 degrees C isotherm.

    Directory of Open Access Journals (Sweden)

    Leslie A Reperant

    2010-04-01

    Full Text Available Wild bird movements and aggregations following spells of cold weather may have resulted in the spread of highly pathogenic avian influenza virus (HPAIV H5N1 in Europe during the winter of 2005-2006. Waterbirds are constrained in winter to areas where bodies of water remain unfrozen in order to feed. On the one hand, waterbirds may choose to winter as close as possible to their breeding grounds in order to conserve energy for subsequent reproduction, and may be displaced by cold fronts. On the other hand, waterbirds may choose to winter in regions where adverse weather conditions are rare, and may be slowed by cold fronts upon their journey back to the breeding grounds, which typically starts before the end of winter. Waterbirds will thus tend to aggregate along cold fronts close to the 0 degrees C isotherm during winter, creating conditions that favour HPAIV H5N1 transmission and spread. We determined that the occurrence of outbreaks of HPAIV H5N1 infection in waterbirds in Europe during the winter of 2005-2006 was associated with temperatures close to 0 degrees C. The analysis suggests a significant spatial and temporal association of outbreaks caused by HPAIV H5N1 in wild birds with maximum surface air temperatures of 0 degrees C-2 degrees C on the day of the outbreaks and the two preceding days. At locations where waterbird census data have been collected since 1990, maximum mallard counts occurred when average and maximum surface air temperatures were 0 degrees C and 3 degrees C, respectively. Overall, the abundance of mallards (Anas platyrhynchos and common pochards (Aythya ferina was highest when surface air temperatures were lower than the mean temperatures of the region investigated. The analysis implies that waterbird movements associated with cold weather, and congregation of waterbirds along the 0 degrees C isotherm likely contributed to the spread and geographical distribution of outbreaks of HPAIV H5N1 infection in wild birds in

  20. Application of Cascade Refrigeration System with Mixing Refrigerant in Cold Air Cutting

    Science.gov (United States)

    Yang, Y.; Tong, M. W.; Yang, G.; Wang, X. P.

    In the mechanical cutting process, the replacement of traditional cutting solution with cold air can avoid the pollution of environment. In order to high efficient the refrigerating device and flexible adjust the temperature of cold air, it is necessary to use cascade refrigeration system to supply cool quantity for the compressed air. The introduction of a two-component non-azeotropic mixing refrigerant into the cryogenic part of the cascade system, can effectively solve the problems of the system working at too high pressure and the volume expanding of refrigerant in case of the cascade refrigeration sets closed down. However, the filling ratio of mixing refrigerants impact on the relationships among the closing down pressure, refrigerating output and refrigerating efficiency. On the basis of computing and experiment, the optimal mixing ratio of refrigerant R22/R13 and a low temperature of -60° were obtained in this study. A cold air injecting device possessing high efficiency in energy saving has also been designed and manufactured. The cold air, generated from this cascade system and employed in a cutting process, takes good comprehensive effects on machining and cutting.

  1. Performance enhancement of a subcooled cold storage air conditioning system

    International Nuclear Information System (INIS)

    Hsiao, M.-J.; Cheng, C.-H.; Huang, M.-C.; Chen, S.-L.

    2009-01-01

    This article experimentally investigates the enhancement of thermal performance for an air conditioning system utilizing a cold storage unit as a subcooler. The cold storage unit is composed of an energy storage tank, liquid-side heat exchanger, suction-side heat exchanger and energy storage material (ESM), water. When the cooling load is lower than the nominal cooling capacity of the system, the cold storage unit can store extra cold energy of the system to subcool the condenser outlet refrigerant. Hence, both the cooling capacity and coefficient of performance (COP) of the system will be increased. This experiment tests the two operation modes: subcooled mode with energy storage and non-subcooled mode without energy storage. The results show that for fixed cooling loads at 3.05 kW, 3.5 kW and 3.95 kW, the COP of the subcooled mode are 16.0%, 15.6% and 14.1% higher than those of the non-subcooled mode, respectively. In the varied cooling load experiments, the COP of the subcooled cold storage air conditioning system is 15.3% higher than the conventional system.

  2. Cold air challenge and specific airway resistance in preschool children

    DEFF Research Database (Denmark)

    Nielsen, Kim Gjerum; Bisgaard, Hans

    2005-01-01

    prognosis in preschool children. Cold air challenge and plethysmographic measurement of specific airway resistance (sRaw) are feasible candidate methods for diagnosis, clinical monitoring and research during this critical period of lung growth and development. Methodology and practical aspects of cold air...... challenge and assessment of sRaw in preschool children are reviewed. Reference values are provided for sRaw and have allowed discrimination between health and respiratory disease, both in cross-sectional and longitudinal studies. Bronchial hyperresponsiveness can be determined with acceptable repeatability...

  3. Indoor air quality in cold climates: hazards and abatement measures

    National Research Council Canada - National Science Library

    Walkinshaw, D. S

    1986-01-01

    The first APCA Conference on Indoor Air Quality, held April 29, 30 and May 1, 1985 in Ottawa, featured some 67 presentations covering many aspects of indoor air quality, with the focus on cold climate...

  4. High Time Resolution Measurements of VOCs from Vehicle Cold Starts: The Air Toxic Cold Start Pulse

    Science.gov (United States)

    Jobson, B. T.; Huangfu, Y.; Vanderschelden, G. S.

    2017-12-01

    Pollutants emitted during motor vehicle cold starts, especially in winter in some climates, is a significant source of winter time air pollution. While data exist for CO, NO, and total hydrocarbon emissions from federal testing procedures for vehicle emission certification, little is known about the emission rates of individual volatile organic compounds, in particular the air toxics benzene, formaldehyde, and acetaldehyde. Little is known about the VOC speciation and temperature dependence for cold starts. The US EPA vehicle emission model MOVES assumes that cold start emissions have the same speciation profile as running emissions. We examined this assumption by measuring cold start exhaust composition for 4 vehicles fueled with E10 gasoline over a temperature range of -4°C to 10°C in winter of 2015. The extra cold start emissions were determined by comparison with emissions during engine idling. In addition to CO and NOx measurements a proton transfer reaction mass spectrometer was used to measure formaldehyde, acetaldehyde, benzene, toluene, and C2-alkylbenzenes at high time resolution to compare with the cold start emission speciation profiles used in the EPA MOVES2014 model. The results show that after the vehicle was started, CO mixing ratios can reach a few percent of the exhaust and then drop to several ppmv within 2 minutes of idling, while NOx showed different temporal behaviors among the four vehicles. VOCs displayed elevated levels during cold start and the peak mixing ratios can be two orders higher than idling phase levels. Molar emission ratios relative to toluene were used to compare with the emission ratio used in MOVES2014 and we found the formaldehyde-to-toluene emission ratio was about 0.19, which is 5 times higher than the emission ratio used in MOVES2014 and the acetaldehyde-to-toluene emission ratios were 0.86-0.89, which is 8 times higher than the ones in MOVES2014. The C2-alkylbenzene-to-toluene ratio agreed well with moves. Our results

  5. Adsorption cold storage system with zeolite-water working pair used for locomotive air conditioning

    International Nuclear Information System (INIS)

    Lu, Y.Z.; Wang, R.Z.; Zhang, M.; Jiangzhou, S.

    2003-01-01

    Adsorption cold storage has lately attracted attention for its large storage capacity and zero cold energy loss during the storing process. Thermodynamic and experimental studies on the cold storage capacity and the cold discharging process, in which the adsorber is either air cooled or adiabatic, have been presented. An adsorption cold storage system with zeolite-water working pair has been developed, and some operating results are summarized. This system is used for providing air conditioning for the driver's cab of an internal combustion locomotive. Unlike a normal adsorption air conditioner, the system starts running with the adsorption process, during which the cold energy stored is discharged, and ends running with the generation process. The adsorbent temperature decreases during the cold storing period between two runs. The refrigeration power output for the whole running cycle is about 4.1 kW. It appears that such a system is quite energetically efficient and is comparatively suitable for providing discontinuous refrigeration capacity when powered by low grade thermal energy, such as industrial exhausted heat or solar energy

  6. Nasal mucosa secretion exudation response to cold air in bronchial asthma patients

    Directory of Open Access Journals (Sweden)

    Eduard V. Nekrasov

    2017-01-01

    Full Text Available Background. Combined airway hyper responsiveness to cold and hypoosmotic stimuli in asthma patients results in impairment of lung respiration function and poor disease control compared to patients with isolated airway hyper responsiveness to only one of the stimuli or without such responsiveness that can be connected with edema or mucus hypersecretion.Aim. The purpose of the study is the estimation of the processes of mucin secretion, plasma exudation and oxidative stress in response to cold air in asthma patients with combined airway responsiveness to cold and hypoosmotic stimuli using nasal mucosa as a model.Materials and methods. 23 patients with asthma participated in the study. For the nasal lavage procedure, a nasal cavity was pre-washed at least three times in 5-min intervals with 5 ml saline solution (~36 °C. A control nasal lavage was done 5 min after the last washing with a dwelling time of 1 min in the nasal cavity. Directly after the control lavage, a cold air nasal challenge was done: a participant was asked to breathe deeply at the pace of a metronome to ensure hyperventilation inhaling cold air (–20 °C through the nose and exhaling through the mouth for 5 min. Nasal lavages were taken at 1 min, 15, and 30 min after the challenge. Mucin secretion was estimated on the basis of total protein (TP content, total carbohydrates (TC, and water-soluble forms of mucins MUC5AC and MUC5B in the lavage fluids. For the estimation of plasma exudation, the concentration of α2-macroglobulin (α2-MG was measured. Oxidative stress was estimated by the content of thiobarbituric acid-reactive substances (TBARS in lavage fluid. Lung function and airway responsiveness were studied by the forced expiration spirometry method and the bronchial challenge tests with isocapnic cold air hyperventilation (CAHV and distilled water inhalation (DWI.Results. According to the bronchial challenge tests, the patients were divided into groups: 1 without airway

  7. Study of Cycling Air-Cooling System with a Cold Accumulator for Micro Gas-Turbine Installations

    Science.gov (United States)

    Ochkov, V. F.; Stepanova, T. A.; Katenev, G. M.; Tumanovskii, V. A.; Borisova, P. N.

    2018-05-01

    Using the cycling air-cooling systems of the CTIC type (Combustion Turbine Inlet Cooling) with a cold accumulator in a micro gas-turbine installation (micro-GTI) to preserve its capacity under the seasonal temperature rise of outside air is described. Water ice is used as the body-storage in the accumulators, and ice water (water at 0.5-1.0°C) is used as the body that cools air. The ice water circulates between the accumulator and the air-water heat exchanger. The cold accumulator model with renewable ice resources is considered. The model contains the heat-exchanging tube lattice-evaporator covered with ice. The lattice is cross-flowed with water. The criterion heat exchange equation that describes the process in the cold accumulator under consideration is presented. The calculations of duration of its active operation were performed. The dependence of cold accumulator service life on water circulation rate was evaluated. The adequacy of the design model was confirmed experimentally in the mock-up of the cold accumulator with a refrigerating machine periodically creating a 200 kg ice reserve in the reservoir-storage. The design model makes it possible to determine the weight of ice reserve of the discharged cold accumulator for cooling the cycle air in the operation of a C-30 type micro- GTI produced by the Capstone Company or micro-GTIs of other capacities. Recommendations for increasing the working capacity of cold accumulators of CTIC-systems of a micro-GTI were made.

  8. Cross-border outbreak of listeriosis caused by cold-smoked salmon, revealed by integrated surveillance and whole genome sequencing (WGS), Denmark and France, 2015 to 2017

    DEFF Research Database (Denmark)

    Schjorring, Susanne; Lassen, Sofie Gillesberg; Jensen, Tenna

    2017-01-01

    In August 2017, an outbreak of six listeriosis cases in Denmark was traced to cold-smoked salmon, using epidemiological investigations and whole-genome sequencing (WGS) analyses. Exchange of genome sequences allowed identification in France of a food isolate from a salmon-derived product and a hu......In August 2017, an outbreak of six listeriosis cases in Denmark was traced to cold-smoked salmon, using epidemiological investigations and whole-genome sequencing (WGS) analyses. Exchange of genome sequences allowed identification in France of a food isolate from a salmon-derived product...... and a human isolate from 2016 within the same cgMLST cluster as the Danish isolates (L2-SL8-ST8-CT771). The salmon product came from a third European Union country. WGS can rapidly link human cases and food isolates across Europe....

  9. Tracking Legionella in air generated from a biological treatment plant: a case study of the outbreak of legionellosis in Norway

    Science.gov (United States)

    Blatny, Janet M.; Olsen, Jaran S.; Andreassen, Øyvind; Waagen, Viggo; Reif, Bjørn Anders P.

    2011-05-01

    Two outbreaks of legionellosis occurred in the Sarpsborg/Fredrikstad region southeast of Norway in 2005 and 2008 where more than 60 exposed individuals were infected and 10 case patients died. The air scrubber at Borregaard, a wood-based chemical factory, was identified as the outbreak source. High concentration levels of Legionella species, including the etiological agent L. pneumophila SG1 was found in the aeration ponds, which belongs to Borregaard's biological treatment plant. Results showed that these ponds were able to generate Legionella-containing aerosols that were transported by the wind as such aerosols were measured up to 200 meters downwind of the pond. Our studies did not detect L. pneumophila SG1 isolates, only L. pneumophila SG4 during the air sampling measurement campaign. Furthermore, the operational conditions of the air scrubber proved to be harsh for Legionella growth as the outbreak L. pneumophila strains were not able to grow at 45ºC and pH8 (conditions during the outbreaks). These results, together, lead us to suggest that the aeration pond should be regarded as the primary amplifier and disseminator of Legionella and L. pneumophila and thereby most likely being the outbreak source.

  10. Logistic advantages of an air curtain in a cold store; Heiploeg ervaart logistieke voordelen van vrieshuis-luchtgordijn

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2001-07-01

    Fog and ice are problems in cold storage warehouses. A manufacturer of air conditioning equipment (Biddle in Kootstertille, Netherlands) claims to have found the solution in the so-called Multi Air stream Technology, an air curtain for cold stores.

  11. Inversion Build-Up and Cold-Air Outflow in a Small Alpine Sinkhole

    Science.gov (United States)

    Lehner, Manuela; Whiteman, C. David; Dorninger, Manfred

    2017-06-01

    Semi-idealized model simulations are made of the nocturnal cold-air pool development in the approximately 1-km wide and 100-200-m deep Grünloch basin, Austria. The simulations show qualitatively good agreement with vertical temperature and wind profiles and surface measurements collected during a meteorological field expedition. A two-layer stable atmosphere forms in the basin, with a very strong inversion in the lowest part, below the approximate height of the lowest gap in the surrounding orography. The upper part of the stable layer is less strongly stratified and extends to the approximate height of the second-lowest gap. The basin atmosphere cools most strongly during the first few hours of the night, after which temperatures decrease only slowly. An outflow of air forms through the lowest gap in the surrounding orography. The outflow connects with a weak inflow of air through a gap on the opposite sidewall, forming a vertically and horizontally confined jet over the basin. Basin cooling shows strong sensitivity to surface-layer characteristics, highlighting the large impact of variations in vegetation and soil cover on cold-air pool development, as well as the importance of surface-layer parametrization in numerical simulations of cold-air-pool development.

  12. Two listeria outbreaks caused by smoked fish consumption-using whole-genome sequencing for outbreak investigations

    DEFF Research Database (Denmark)

    Gillesberg Lassen, S.; Ethelberg, S.; Björkman, J. T.

    2016-01-01

    low-intensity, extended time-period outbreaks and link them to food products from two different contaminated production facilities with sufficient strength for food authorities to intervene on. Cold smoked and gravad fish constitute risk products and may be responsible for more listeriosis cases than......Listeria monocytogenes may contaminate and persist in food production facilities and cause repeated, seemingly sporadic, illnesses over extended periods of time. We report on the investigation of two such concurrent outbreaks. We compared patient isolates and available isolates from foods and food...... polymorphism differences. We performed routine food consumption interviews of L. monocytogenes patients and compared outbreak cases with sporadic cases. Two outbreaks were defined, each consisting of ten outbreak cases in the period 2013-15. Seven outbreak cases and a fetus in gestational week 38 died...

  13. [Influence of industrial pollution of ambient air on health of workers engaged into open air activities in cold conditions].

    Science.gov (United States)

    Chashchin, V P; Siurin, S A; Gudkov, A B; Popova, O N; Voronin, A Iu

    2014-01-01

    The article presents the results of a study on assessment of occupational exposure to air pollutants and related health effects in3792 outdoor workers engaged in operations performed in the vicinity of non-ferrous metallurgical facilities in Far North. Findings are that during cold season repeated climate and weather conditions are associated with higher level of chemical hazards and dust in surface air. At the air temperature below -17 degrees C, maximal single concentrations of major pollutants can exceed MAC up to 10 times. With that, transitory disablement morbidity parameters and occupational accidents frequency increase significantly. The workers with long exposure to cooling meteorological factors and air pollution demonstrate significantly increased prevalence of respiratory and circulatory diseases, despite relatively low levels of sculpture dioxide and dust in the air, not exceeding the occupational exposure limits. It has been concluded that severe cold is to be considered asa factor increasing occupational risk at air polluted outdoor worksites dueto more intense air pollution, higher traumatism risk and lower efficiency of filter antidust masks respiratory PPE and due to modification of the toxic effects.

  14. Measles Outbreak among Unvaccinated Children in Bajura

    Directory of Open Access Journals (Sweden)

    S Sitaula

    2010-12-01

    CFR of this outbreak is higher than the national CFR. Vaccine efficacy of 50% points towards the need for investigation of vaccine logistics and cold chain system. Moreover, this laboratory test confirmed an outbreak showing that the measles virus could be imported from an endemic region and rapidly spread through a susceptible population who were previously not immunized.

  15. Cold air plasma to decontaminate inanimate surfaces of the hospital environment.

    Science.gov (United States)

    Cahill, Orla J; Claro, Tânia; O'Connor, Niall; Cafolla, Anthony A; Stevens, Niall T; Daniels, Stephen; Humphreys, Hilary

    2014-03-01

    The hospital environment harbors bacteria that may cause health care-associated infections. Microorganisms, such as multiresistant bacteria, can spread around the patient's inanimate environment. Some recently introduced biodecontamination approaches in hospitals have significant limitations due to the toxic nature of the gases and the length of time required for aeration. This study evaluated the in vitro use of cold air plasma as an efficient alternative to traditional methods of biodecontamination of hospital surfaces. Cultures of methicillin-resistant Staphylococcus aureus (MRSA), vancomycin-resistant enterococci (VRE), extended-spectrum-β-lactamase (ESBL)-producing Escherichia coli, and Acinetobacter baumannii were applied to different materials similar to those found in the hospital environment. Artificially contaminated sections of marmoleum, mattress, polypropylene, powder-coated mild steel, and stainless steel were then exposed to a cold air pressure plasma single jet for 30 s, 60 s, and 90 s, operating at approximately 25 W and 12 liters/min flow rate. Direct plasma exposure successfully reduced the bacterial load by log 3 for MRSA, log 2.7 for VRE, log 2 for ESBL-producing E. coli, and log 1.7 for A. baumannii. The present report confirms the efficient antibacterial activity of a cold air plasma single-jet plume on nosocomial bacterially contaminated surfaces over a short period of time and highlights its potential for routine biodecontamination in the clinical environment.

  16. Hyperventilation with cold versus dry air in 2- to 5-year-old children with asthma

    DEFF Research Database (Denmark)

    Nielsen, Kim G; Bisgaard, Hans

    2005-01-01

    UNLABELLED: Cold air challenge (CACh) has been shown to discriminate between children with asthma and healthy young children. Hyperventilation with dry room-temperature air is a simplified alternative. We compared responsiveness in young children with asthma between two standardized, single......-subject SDs (SDw). The challenge sequence was randomly assigned. A comparator challenge was performed 1 hour later if the first challenge gave a change of 3 SDw or more. Forty 2- to 5-year-old children with asthma were included. Responsiveness to cold versus dry air showed significant, but weak, correlation...

  17. Synoptic climatological analysis of persistent cold air pools over the Carpathian Basin

    Science.gov (United States)

    Szabóné André, Karolina; Bartholy, Judit; Pongrácz, Rita

    2016-04-01

    A persistent cold air pool (PCAP) is a winter-time, anticyclone-related weather event over a relatively large basin. During this time the air is colder near the surface than aloft. This inversion near the surface can last even for weeks. As the cold air cools down, relative humidity increases and fog forms. The entire life cycle of a PCAP depends on the large scale circulation pattern. PCAP usually appears when an anticyclone builds up after a cold front passed over the examined basin, and it is usually destructed by a coming strong cold front of another midlatitude cyclone. Moreover, the intensity of the anticyclone affects the intensity of the PCAP. PCAP may result in different hazards for the population: (1) Temperature inversion in the surface layers together with weak wind may lead to severe air pollution causing health problems for many people, especially, elderly and children. (2) The fog and/or smog during chilly weather conditions often results in freezing rain. Both fog and freezing rain can distract transportation and electricity supply. Unfortunately, the numerical weather prediction models have difficulties to predict PCAP formation and destruction. One of the reasons is that PCAP is not defined objectively with a simple formula, which could be easily applied to the numerical output data. However, according to some recommendations from the synoptic literature, the shallow convective potential energy (SCPE) can be used to mathematically describe PCAP. In this study, we used the ERA-Interim reanalysis datasets to examine this very specific weather event (i.e., PCAP) over the Carpathian Basin. The connection between the mean sea level pressure and some PCAP measures (e.g., SCPE, energy deficit, etc.) is evaluated. For instance, we used logistic regression to identify PCAP periods over the Carpathian Basin. Then, further statistical analysis includes the evaluation of the length and intensity of these PCAP periods.

  18. Outbreak of febrile gastroenteritis caused by Listeria monocytogenes 1/2a in sliced cold beef ham, Italy, May 2016

    Science.gov (United States)

    Maurella, Cristiana; Gallina, Silvia; Ru, Giuseppe; Adriano, Daniela; Bellio, Alberto; Bianchi, Daniela Manila; Chiavacci, Laura; Crescio, Maria Ines; Croce, Margherita; D'Errico, Valeria; Dupont, Maria Franca; Marra, Alessandro; Natangelo, Ubaldo; Pomilio, Francesco; Romano, Angelo; Stanzione, Stefano; Zaccaria, Teresa; Zuccon, Fabio; Caramelli, Maria; Decastelli, Lucia

    2018-01-01

    In May 2016, two separate clusters of febrile gastroenteritis caused by Listeria monocytogenes were detected by the local health authority in Piedmont, in northern Italy. We carried out epidemiological, microbiological and traceback investigations to identify the source. The people affected were students and staff members from two different schools in two different villages located in the Province of Turin; five of them were hospitalised. The epidemiological investigation identified a cooked beef ham served at the school canteens as the source of the food-borne outbreak. L. monocytogenes was isolated from the food, the stools of the hospitalised pupils and the environment of the factory producing the cooked beef ham. All isolates except one were serotype 1/2a, shared an indistinguishable PFGE pattern and were 100% identical by whole genome sequencing (WGS). By combining a classical epidemiological approach with both molecular subtyping and WGS techniques, we were able to identify and confirm a Listeria gastroenteritis outbreak associated with consumption of sliced cold beef ham. PMID:29536831

  19. The comparison of cold-water immersion and cold air therapy on maximal cycling performance and recovery markers following strength exercises

    Directory of Open Access Journals (Sweden)

    Kane J. Hayter

    2016-03-01

    Full Text Available This study examined the effects of cold-water immersion (CWI and cold air therapy (CAT on maximal cycling performance (i.e. anaerobic power and markers of muscle damage following a strength training session. Twenty endurance-trained but strength-untrained male (n = 10 and female (n = 10 participants were randomised into either: CWI (15 min in 14 °C water to iliac crest or CAT (15 min in 14 °C air immediately following strength training (i.e. 3 sets of leg press, leg extensions and leg curls at 6 repetition maximum, respectively. Creatine kinase, muscle soreness and fatigue, isometric knee extensor and flexor torque and cycling anaerobic power were measured prior to, immediately after and at 24 (T24, 48 (T48 and 72 (T72 h post-strength exercises. No significant differences were found between treatments for any of the measured variables (p > 0.05. However, trends suggested recovery was greater in CWI than CAT for cycling anaerobic power at T24 (10% ± 2%, ES = 0.90, T48 (8% ± 2%, ES = 0.64 and T72 (8% ± 7%, ES = 0.76. The findings suggest the combination of hydrostatic pressure and cold temperature may be favourable for recovery from strength training rather than cold temperature alone.

  20. Using cold battery with icy water as an alternative method of air ...

    African Journals Online (AJOL)

    The aim of this work is to reduce the energy consumption of a passenger ship by using an air conditioning system with a solar energy source. This technique is applied on ships with a cold room with a refrigeration unit. The work consists of using a central air conditioning system for which a heat exchanger is placed in the ...

  1. Detection of Coxiella burnetii in Ambient Air after a Large Q Fever Outbreak.

    Directory of Open Access Journals (Sweden)

    Myrna M T de Rooij

    Full Text Available One of the largest Q fever outbreaks ever occurred in the Netherlands from 2007-2010, with 25 fatalities among 4,026 notified cases. Airborne dispersion of Coxiella burnetii was suspected but not studied extensively at the time. We investigated temporal and spatial variation of Coxiella burnetii in ambient air at residential locations in the most affected area in the Netherlands (the South-East, in the year immediately following the outbreak. One-week average ambient particulate matter < 10 μm samples were collected at eight locations from March till September 2011. Presence of Coxiella burnetii DNA was determined by quantitative polymerase chain reaction. Associations with various spatial and temporal characteristics were analyzed by mixed logistic regression. Coxiella burnetii DNA was detected in 56 out of 202 samples (28%. Airborne Coxiella burnetii presence showed a clear seasonal pattern coinciding with goat kidding. The spatial variation was significantly associated with number of goats on the nearest goat farm weighted by the distance to the farm (OR per IQR: 1.89, CI: 1.31-2.76. We conclude that in the year after a large Q fever outbreak, temporal variation of airborne Coxiella burnetii is suggestive to be associated with goat kidding, and spatial variation with distance to and size of goat farms. Aerosol measurements show to have potential for source identification and attribution of an airborne pathogen, which may also be applicable in early stages of an outbreak.

  2. Exercise in cold air and hydrogen peroxide release in exhaled breath condensate.

    Science.gov (United States)

    Marek, E; Volke, J; Mückenhoff, K; Platen, P; Marek, W

    2013-01-01

    Athletes have changes in the lung epithelial cells caused by inhalation of cold and dry air. The exhaled breath condensate contains a number of mediators from the respiratory system and H(2)O(2) is described as a marker of airways inflammation. The aim of this study was to determine the influence of exercise combined with cold air on the H(2)O(2) release in the exhaled breath. Twelve males (23.1 ± 1.5 years) were randomly assigned at 2 different days (1 day rest) to perform a 50 min run (75-80% of their max. heart rate) under normal (N) laboratory (18.1 ± 1.1°C) or cold (C) field condition (-15.2 ± 3.1°C). Before and immediately after each run, the EBC was collected under laboratory conditions and was analyzed amperometrically. Prior to the two runs, H(2)O(2) concentrations were 145.0 ± 31.0 (N) and 160.0 ± 49.1 nmol/L (C) and theoretical release was 70.3 ± 37.1 (N) and 82.6 ± 27.1 pmol/min (C) (p > 0.05). After each run, H(2)O(2) concentration increased significantly to 388.0 ± 22.8 nmol/L (N) and 622.1 ± 44.2 nmol/L (C) (p release: 249.2 ± 35.7 pmol/min (N) and 400.9 ± 35.7 pmol/min (C) (p release of H(2)O(2) into the EBC takes place under both resting conditions and after exercise. The concentration and release of H(2)O(2) increased after exercise in cold air compared to resting and laboratory conditions, which points to an increase in inflammatory and oxidative stress.

  3. Numerical analysis of the efficiency of earth to air heat exchange systems in cold and hot-arid climates

    International Nuclear Information System (INIS)

    Fazlikhani, Faezeh; Goudarzi, Hossein; Solgi, Ebrahim

    2017-01-01

    Highlights: • A numerical model is developed to evaluate performance of earth to air heat exchanger. • The cooling/heating potential of earth to air heat exchanger is investigated in hot-dry and cold climates. • The more performance of earth to air heat exchanger in hot-dry climates compared to cold climates. • The high efficiency of earth to air heat exchanger for pre-heating in both hot-dry and cold climates. - Abstract: In order to examine and compare the efficiency of earth to air heat exchanger (EAHE) systems in hot-arid (Yazd) and cold (Hamadan) climates in Iran a steady state model was developed to evaluate the impact of various parameters including inlet air temperatures, pipe lengths and ground temperatures on the cooling and heating potential of EAHEs in both climates. The results demonstrated the ability of the system to not only improve the average temperature and decrease the temperature fluctuation of the outlet air temperature of EAHE, but also to trigger considerable energy saving. It was found that in both climates, the system is highly utilized for pre-heating, and its usage is unfeasible in certain periods throughout the year. In winter, EAHEs have the potential of increasing the air temperature in the range of 0.2–11.2 °C and 0.1–17.2 °C for Yazd and Hamadan, respectively. However, in summer, the system decreases the air temperature for the aforementioned cities in the range of 1.3–11.4 °C and 5.7–11.1 °C, respectively. The system ascertains to be more efficient in the hot-arid climate of Yazd, where it can be used on 294 days of the year, leading to 50.1–63.6% energy saving, when compared to the cold climate of Hamadan, where it can be used on 225 days of the year resulting in a reduction of energy consumption by 24.5–47.9%.

  4. Evaluation of simplified ventilation system with direct air supply through the facade in a school in a cold climate

    Energy Technology Data Exchange (ETDEWEB)

    Mysen, M. [Norwegian Building Research Institute, Blindern, Oslo (Norway); Department of Energy and Process Technology, Norwegian University of Science and Technology (NTNU), Trondheim (Norway); Schild, P. G.; Hellstrand, V.; Thunshelle, K. [Norwegian Building Research Institute, Blindern, Oslo (Norway)

    2004-07-01

    Many educational buildings in industrialised countries have poor indoor climate, according to today's knowledge about the impact of indoor climate on well-being and productivity. Budget restrictions and practical limitations such as lack of space for central air handling units and ventilation ducts, have motivated the application of simplified ventilation systems in some schools, such as taking unconditioned supply air directly from the facade. One such school was recently evaluated in Norway. On cold days, thermal comfort in the classroom deteriorated due to cold down draught from the supply outlet. In addition, moist and fertile conditions for microbiological growth were observed in the air supply ductwork. On the other hand the same pupils are more satisfied with the school and have less sick building syndrome (SBS) symptoms during winter than summer. An improved control strategy with a temperature-compensated CO{sub 2} set-point for controlling the air flow is suggested. This could improve thermal comfort and reduce energy use without compromising perceived air quality (PAQ) during cold weather. Furthermore it could improve indoor air quality (IAQ) during warm weather with only a slight increase of energy use. Further evaluation of an improved solution is needed before such a ventilation concept can be recommended in cold climates. (author)

  5. Performance of introducing outdoor cold air for cooling a plant production system with artificial light

    Directory of Open Access Journals (Sweden)

    Jun eWang

    2016-03-01

    Full Text Available The commercial use of a plant production system with artificial light (PPAL is limited by its high initial construction and operation costs. The electric-energy consumed by heat pumps, applied mainly for cooling, accounts for 15-35% of the total electric-energy used in a PPAL. To reduce the electric-energy consumption, an air exchanger with low capacity (180 W was used for cooling by introducing outdoor cold air. In this experiment, the indoor air temperature in two PPALs (floor area: 6.2 m2 each was maintained at 25ºC and 20ºC during light and dark periods, respectively, for lettuce production. In one PPAL (PPALe, an air exchanger (air flow rate: 250 m3 h-1 was used along with a heat pump (cooling capacity: 3.2 kW to maintain the indoor air temperature at the set-point. The other PPAL (PPALc with only a heat pump (cooling capacity: 3.2 kW was used for reference. Effects of introducing outdoor cold air on energy use efficiency, coefficient of performance (COP, electric-energy consumption for cooling and growth of lettuce were investigated. The results show that: when the air temperature difference between indoor and outdoor ranged from 20.2°C to 30.0°C: 1 the average energy use efficiency of the air exchanger was 2.8 and 3.4 times greater than the COP of the heat pumps in the PPALe and PPALc, respectively; 2 hourly electric-energy consumption in the PPALe reduced by 15.8-73.7% compared with that in the PPALc; 3 daily supply of CO2 in the PPALe reduced from 0.15 kg to 0.04 kg compared with that in the PPALc; 4 no significant difference in lettuce growth was observed in both PPALs. The results indicate that using air exchanger to introduce outdoor cold air should be considered as an effective way to reduce electric-energy consumption for cooling with little effects on plant growth in a PPAL.

  6. Cold Vacuum Drying facility heating, ventilation, and Air Conditioning system design description

    International Nuclear Information System (INIS)

    SINGH, G.

    2000-01-01

    This System Design Description (SDD) addresses the HVAC system for the CVDF. The CVDF HVAC system consists of five subsystems: (1) Administration building HVAC system; (2) Process bay recirculation HVAC system; (3) Process bay local exhaust HVAC and process vent system; (4) Process general supply/exhaust HVAC system; and (5) Reference air system. The HVAC and reference air systems interface with the following systems: the fire protection control system, Monitoring and Control System (MCS), electrical power distribution system (including standby power), compressed air system, Chilled Water (CHW) system, drainage system, and other Cold Vacuum Drying (CVD) control systems not addressed in this SDD

  7. Experimental validation of a local dehumidification system based on cold water droplets and air-to-air heat exchanger

    NARCIS (Netherlands)

    Janssen, E.G.O.N.; Hammink, H.A.J.; Hendriksen, L.J.A.M.

    2015-01-01

    Excessive humidity is a problem in Dutch growing circumstances. A traditional solution is heating and natural ventilation. To save energy a number of energy efficient dehumidification methods are developed, like mechanical ventilation with dry outside air or a curtain of cold water droplets. In this

  8. Salmonella outbreak among railway and airline passengers.

    Science.gov (United States)

    Hatakka, M

    1992-01-01

    A widespread outbreak by Salmonella infantis, infecting a total of 226 people, occurred in Finland at the beginning of August 1986. Of those infected, 107 were railway passengers, 91 were airline passengers and 28 were employed in a food processing establishment. The outbreak among the railway passengers was caused by egg sandwiches, the airline passengers were infected by a meal served on board and the catering employees by the breakfast served in the establishment. The outbreak was caused by food prepared in the establishment's kitchen. The employees' breakfasts had probably been contaminated by an employee who was a symptom-free Salmonella infantis carrier, and a number of the employees subsequently became infected, leading to widespread contamination of the food prepared in the establishment. The spread of the outbreak was further influenced by a heatwave at the time and by shortcomings in the cold storage facilities. The kitchen's hygiene supervision and the quality control of its output were reorganized after the outbreak.

  9. Material Transport In The Inner Shelf Of The Northern Gulf Of Mexico

    Science.gov (United States)

    2016-12-01

    portion of the WFS. Cold fronts associated with strong winter extratropical storms , also referred to as Cold Air Outbreaks (CAO), propagate west to...coastline in the northeastern Gulf of Mexico with both field observations and a numerical model simulation. In response to these extratropical storms ...and spring, extratropical cold air outbreaks frequently pass from the north, northwest across the nearly latitudinal coastline and experiment site

  10. Prediction of cold start hydrocarbon emissions of air cooled two wheeler spark ignition engines by simple fuzzy logic simulation

    Directory of Open Access Journals (Sweden)

    Samuel Raja Ayyanan

    2014-01-01

    Full Text Available The cold start hydrocarbon emission from the increasing population of two wheelers in countries like India is one of the research issues to be addressed. This work describes the prediction of cold start hydrocarbon emissions from air cooled spark ignition engines through fuzzy logic technique. Hydrocarbon emissions were experimentally measured from test engines of different cubic capacity, at different lubricating oil temperature and at different idling speeds with and without secondary air supply in exhaust. The experimental data were used as input for modeling average hydrocarbon emissions for 180 seconds counted from cold start and warm start of gasoline bike engines. In fuzzy logic simulation, member functions were assigned for input variables (cubic capacity and idling rpm and output variables (average hydrocarbon emission for first 180 seconds at cold start and warm start. The knowledge based rules were adopted from the analyzed experimental data and separate simulations were carried out for predicting hydrocarbon emissions from engines equipped with and without secondary air supply. The simulation yielded the average hydrocarbon emissions of air cooled gasoline engine for a set of given input data with accuracy over 90%.

  11. Evaporative cooling enhanced cold storage system

    Science.gov (United States)

    Carr, P.

    1991-10-15

    The invention provides an evaporatively enhanced cold storage system wherein a warm air stream is cooled and the cooled air stream is thereafter passed into contact with a cold storage unit. Moisture is added to the cooled air stream prior to or during contact of the cooled air stream with the cold storage unit to effect enhanced cooling of the cold storage unit due to evaporation of all or a portion of the added moisture. Preferably at least a portion of the added moisture comprises water condensed during the cooling of the warm air stream. 3 figures.

  12. Cold Heat Release Characteristics of Solidified Oil Droplet-Water Solution Latent Heat Emulsion by Air Bubbles

    Science.gov (United States)

    Inaba, Hideo; Morita, Shin-Ichi

    The present work investigates the cold heat-release characteristics of the solidified oil droplets (tetradecane, C14H30, freezing point 278.9 K)/water solution emulsion as a latent heat-storage material having a low melting point. An air bubbles-emulsion direct-contact heat exchange method is selected for the cold heat-results from the solidified oil droplet-emulsion layer. This type of direct-contact method results in the high thermal efficiency. The diameter of air bubbles in the emulsion increases as compared with that in the pure water. The air bubbles blown from a nozzle show a strong mixing behavior during rising in the emulsion. The temperature effectiveness, the sensible heat release time and the latent heat release time have been measured as experimental parameters. The useful nondimensional emulsion level equations for these parameters have been derived in terms of the nondimensional emalsion level expressed the emulsion layer dimensions, Reynolds number for air flow, Stefan number and heat capacity ratio.

  13. Cold, dry air is associated with influenza and pneumonia mortality in Auckland, New Zealand.

    Science.gov (United States)

    Davis, Robert E; Dougherty, Erin; McArthur, Colin; Huang, Qiu Sue; Baker, Michael G

    2016-07-01

    The relationship between weather and influenza and pneumonia mortality was examined retrospectively using daily data from 1980 to 2009 in Auckland, New Zealand, a humid, subtropical location. Mortality events, defined when mortality exceeded 0·95 standard deviation above the mean, followed periods of anomalously cold air (ta.m. = -4·1, P < 0·01; tp.m. = -4·2, P < 0·01) and/or anomalously dry air (ta.m. = -4·1, P < 0·01; tp.m. = -3·8, P < 0·01) by up to 19 days. These results suggest that respiratory infection is enhanced during unusually cold conditions and during conditions with unusually low humidity, even in a subtropical location where humidity is typically high. © 2015 The Authors. Influenza and Other Respiratory Viruses Published by John Wiley & Sons Ltd.

  14. Sea Surface Temperature from MODIS during Saharan Air Layer outbreaks: Multichannel vs Optimal Estimation.

    Science.gov (United States)

    Szczodrak, G.; Minnett, P. J.

    2017-12-01

    The current Sea-Surface Temperature (SST) retrieval algorithms applied to MODIS and VIIRS data are build on the Non-Linear SST algorithm (NLSST Walton et al., 1998). This algorithm is based on combination of top-of-atmosphere brightness temperatures, T11 and T12 measured at λ= 11µm and 12µm. The algorithm has a set of coefficients derived using collocated measurements of SST temperature from drifting buoys (Match-Up Data Base - MUDB). NLSST produces accurate SST retrievals in conditions that are similar to those of the represented in the MUDB. When conditions deviate from typical, the errors are larger. An alternative approach of estimating the SST from radiance measurements is based on the Optimal Estimation (OE). The OE approach is not tied to a MUDB so OESST should be free of the systematic biases seen in NLSST retrievals in anomalous conditions. OE uses prior knowledge or estimation of a system as an input of a forward model to simulate `observations' and seeks to minimize the difference between these simulated observation and actual measurements in the space of the state variables. One situation that leads to significant bias in NLSST occurs in Northern Atlantic near the African coast during Saharan Air Layer (SAL) outbreaks. Typically, the atmosphere in this region is moist and these conditions are represented in the coefficients of the NLSST algorithm. During SAL events, moist air is replaced by a layer of very dry air; the established coefficients are no longer representative. During a number of research cruises in the North Atlantic affected by the SAL, we have collected radiometric SST measurements from ships using the Marine Atmosphere Emitted Radiance Interferometer (M-AERI), and frequent measurements of the atmospheric state with radiosondes launched from the ships. Using these data, we investigate if the OE approach is capable of improving the accuracy of the SST retrieval from MODIS under the conditions of the dry air outbreak from the Sahara.

  15. Airtightness Results of Roof-Only Air Sealing Strategies on 1 ½-Story Homes in Cold Climates

    Energy Technology Data Exchange (ETDEWEB)

    Ojczyk, C.; Murry, T.; Mosiman, G.

    2014-07-01

    In this second study on solutions to ice dams in 1-1/2 story homes, the NorthernSTAR Building America Partnership team analyzed five test homes located in both cold and very cold climates for air leakage reduction rates following modifications by independent contractors on owner-occupied homes. These homes were chosen for testing as they are common in Minnesota and very difficult to air seal and insulate effectively. Two projects followed a roof-only Exterior Thermal Moisture Management System (ETMMS) process. One project used an interior-only approach to roof air sealing and insulation. The remaining two projects used a deep energy retrofit approach for whole house (foundation wall, above grade wall, roof) air leakage and heat loss reduction. All were asked to provide information regarding project goals, process, and pre and post-blower door test results. Additional air leakage reduction data was provided by several NorthernSTAR industry partners for interior-applied, roof-only modifications on 1-1/2 story homes. The data represents homes in the general market as well as homes that were part of the state of Minnesota weatherization program. A goal was to compare exterior air sealing methods with interior approaches. This pool of data enabled the team to compare air tightness data from over 220 homes using similar air seal methods.

  16. Influence of Northeast Monsoon cold surges on air quality in Southeast Asia

    Science.gov (United States)

    Ashfold, M. J.; Latif, M. T.; Samah, A. A.; Mead, M. I.; Harris, N. R. P.

    2017-10-01

    Ozone (O3) is an important ground-level pollutant. O3 levels and emissions of O3 precursors have increased significantly over recent decades in East Asia and export of this O3 eastward across the Pacific Ocean is well documented. Here we show that East Asian O3 is also transported southward to tropical Southeast (SE) Asia during the Northeast Monsoon (NEM) season (defined as November to February), and that this transport pathway is especially strong during 'cold surges'. Our analysis employs reanalysis data and measurements from surface sites in Peninsular Malaysia, both covering 2003-2012, along with trajectory calculations. Using a cold surge index (northerly winds at 925 hPa averaged over 105-110°E, 5°N) to define sub-seasonal strengthening of the NEM winds, we find the largest changes in a region covering much of the Indochinese Peninsula and surrounding seas. Here, the levels of O3 and another key pollutant, carbon monoxide, calculated by the Monitoring Atmospheric Composition and Climate (MACC) Reanalysis are on average elevated by, respectively, >40% (∼15 ppb) and >60% (∼80 ppb) during cold surges. Further, in the broader region of SE Asia local afternoon exceedances of the World Health Organization's air quality guideline for O3 (100 μg m-3, or ∼50 ppb, averaged over 8 h) largely occur during these cold surges. Day-to-day variations in available O3 observations at surface sites on the east coast of Peninsular Malaysia and in corresponding parts of the MACC Reanalysis are similar, and are clearly linked to cold surges. However, observed O3 levels are typically ∼10-20 ppb lower than the MACC Reanalysis. We show that these observations are also subject to influence from local urban pollution. In agreement with past work, we find year-to-year variations in cold surge activity related to the El Nino-Southern Oscillation (ENSO), but this does not appear to be the dominant influence of ENSO on atmospheric composition in this region. Overall, our study

  17. Incorporating cold-air pooling into downscaled climate models increases potential refugia for snow-dependent species within the Sierra Nevada Ecoregion, CA.

    Directory of Open Access Journals (Sweden)

    Jennifer A Curtis

    Full Text Available We present a unique water-balance approach for modeling snowpack under historic, current and future climates throughout the Sierra Nevada Ecoregion. Our methodology uses a finer scale (270 m than previous regional studies and incorporates cold-air pooling, an atmospheric process that sustains cooler temperatures in topographic depressions thereby mitigating snowmelt. Our results are intended to support management and conservation of snow-dependent species, which requires characterization of suitable habitat under current and future climates. We use the wolverine (Gulo gulo as an example species and investigate potential habitat based on the depth and extent of spring snowpack within four National Park units with proposed wolverine reintroduction programs. Our estimates of change in spring snowpack conditions under current and future climates are consistent with recent studies that generally predict declining snowpack. However, model development at a finer scale and incorporation of cold-air pooling increased the persistence of April 1st snowpack. More specifically, incorporation of cold-air pooling into future climate projections increased April 1st snowpack by 6.5% when spatially averaged over the study region and the trajectory of declining April 1st snowpack reverses at mid-elevations where snow pack losses are mitigated by topographic shading and cold-air pooling. Under future climates with sustained or increased precipitation, our results indicate a high likelihood for the persistence of late spring snowpack at elevations above approximately 2,800 m and identify potential climate refugia sites for snow-dependent species at mid-elevations, where significant topographic shading and cold-air pooling potential exist.

  18. Airtightness Results of Roof-Only Air Sealing Strategies on 1-1/2 Story Homes in Cold Climates

    Energy Technology Data Exchange (ETDEWEB)

    Ojczyk, C.; Murry, T.; Mosiman, G.

    2014-07-01

    In this second study on solutions to ice dams in 1-1/2 story homes, five test homes located in both cold and very cold climates were analyzed for air leakage reduction rates following modifications by independent contractors on owner-occupied homes. The reason for choosing this house type was they are very common in our area and very difficult to air seal and insulate effectively. Two projects followed a roof-only Exterior Thermal Moisture Management System (ETMMS) process. One project used an interior-only approach to roof air sealing and insulation. The remaining two projects used a deep energy retrofit approach for whole house (foundation wall, above grade wall, roof) air leakage and heat loss reduction. All were asked to provide information regarding project goals, process, and pre and post-blower door test results. Additional air leakage reduction data was provided by several NorthernSTAR Building America industry partners for interior-applied, roof-only modifications on 1-1/2 story homes. The data represents homes in the general market as well as homes that were part of the state of Minnesota weatherization program. A goal was to compare exterior air sealing methods with interior approaches. This pool of data enabled us to compare air tightness data from over 220 homes using similar air seal methods.

  19. Hypothermic general cold adaptation induced by local cold acclimation.

    Science.gov (United States)

    Savourey, G; Barnavol, B; Caravel, J P; Feuerstein, C; Bittel, J H

    1996-01-01

    To study relationships between local cold adaptation of the lower limbs and general cold adaptation, eight subjects were submitted both to a cold foot test (CFT, 5 degrees C water immersion, 5 min) and to a whole-body standard cold air test (SCAT, 1 degree C, 2 h, nude at rest) before and after a local cold acclimation (LCA) of the lower limbs effected by repeated cold water immersions. The LCA induced a local cold adaptation confirmed by higher skin temperatures of the lower limbs during CFT and a hypothermic insulative general cold adaptation (decreased rectal temperature and mean skin temperature P adaptation was related to the habituation process confirmed by decreased plasma concentrations of noradrenaline (NA) during LCA (P general cold adaptation was unrelated either to local cold adaptation or to the habituation process, because an increased NA during SCAT after LCA (P syndrome" occurring during LCA.

  20. Cold And Flu: Conventional vs Botanical & Nutritional Therapy

    OpenAIRE

    KALRA M; KHATAK M; KHATAK S

    2011-01-01

    Cold and flu (or Influenza) are both respiratory illnesses and the terms are used interchangeably. However, they are both caused by different viruses. There are two main types of flu viruses: influenza A and influenza B. The most serious and deadly flu outbreaks are caused by influenza A because of its ability to genetically shift into new forms against which no person has developed immunity. Influenza B generally causes less severe infection. Outbreaks of influenza B commonly occur in school...

  1. Outbreak of carbon tetrachloride poisoning in a color printing factory related to the use of isopropyl alcohol and an air conditioning system in Taiwan.

    Science.gov (United States)

    Deng, J F; Wang, J D; Shih, T S; Lan, F L

    1987-01-01

    Three workers from a color printing factory were admitted to community hospitals in 1985 with manifestations of acute hepatitis. One of the three had superimposed acute renal failure and pulmonary edema. An investigation was subsequently conducted at the plant to determine the etiology of the outbreak and the prevalence of liver disease among the remaining workers. Comprehensive medical evaluations were conducted, which included physical examinations, liver function tests, and serological screening for hepatitis. Seventeen of 25 workers from the plant had abnormal liver function tests 10 days after the outbreak, and a significant association was found between the presence of abnormal liver function tests and a history of recently having worked inside any of three rooms in which an interconnecting air conditioning system had been installed to cool the printing machines. After further investigation, it was determined that the incident occurred following inadvertent use of carbon tetrachloride to clean a pump in the printing machine. A simulation of the pump cleaning operation revealed ambient air levels of carbon tetrachloride of 300-500 ppm. Ultimately, it was concluded that the outbreak was in all likelihood due to the combined use of carbon tetrachloride and isopropyl alcohol in the cleaning operation. This outbreak underscores the importance of adopting appropriate industrial hygiene measures in a rapidly industrializing nation such as Taiwan.

  2. Curriculum Evolution at Air Command and Staff College in the Post-Cold War Era

    Science.gov (United States)

    Donovan, William Robert, II.

    2010-01-01

    This qualitative study used a historical research method to eliminate the gap in the historical knowledge of Air Command and Staff College (ACSC) curriculum evolution in the post-Cold War era. This study is the only known analysis of the forces that influenced the ACSC curriculum and the rationale behind curricular change at ACSC in the post-Cold…

  3. Détente from the Air: Monitoring Air Pollution during the Cold War.

    Science.gov (United States)

    Rothschild, Rachel

    During the period of détente in the 1970s, a Norwegian proposal to construct an air pollution monitoring network for the European continent resulted in the first concrete collaboration between the communist and capitalist blocs after the 1975 Helsinki Accords. Known as the "European-wide monitoring programme" or EMEP, the network earned considerable praise from diplomats for facilitating cooperation across the Iron Curtain. Yet as this article argues, EMEP was strongly influenced by the politics of détente and the constraints of the Cold War even as it helped to decrease tensions. Concerns about national security and sharing data with the enemy shaped both the construction of the monitoring network and the modeling of pollution transport. The article also proposes that environmental monitoring systems like EMEP reveal the ways in which observational technologies can affect conceptions of the natural world and the role of science in public policy.

  4. Variability of cold season surface air temperature over northeastern China and its linkage with large-scale atmospheric circulations

    Science.gov (United States)

    Zhuang, Yuanhuang; Zhang, Jingyong; Wang, Lin

    2018-05-01

    Cold temperature anomalies and extremes have profound effects on the society, the economy, and the environment of northeastern China (NEC). In this study, we define the cold season as the months from October to April, and investigate the variability of cold season surface air temperature (CSAT) over NEC and its relationships with large-scale atmospheric circulation patterns for the period 1981-2014. The empirical orthogonal function (EOF) analysis shows that the first EOF mode of the CSAT over NEC is characterized by a homogeneous structure that describes 92.2% of the total variance. The regionally averaged CSAT over NEC is closely linked with the Arctic Oscillation ( r = 0.62, 99% confidence level) and also has a statistically significant relation with the Polar/Eurasian pattern in the cold season. The positive phases of the Arctic Oscillation and the Polar/Eurasian pattern tend to result in a positive geopotential height anomaly over NEC and a weakened East Asian winter monsoon, which subsequently increase the CSAT over NEC by enhancing the downward solar radiation, strengthening the subsidence warming and warm air advection. Conversely, the negative phases of these two climate indices result in opposite regional atmospheric circulation anomalies and decrease the CSAT over NEC.

  5. Measurements and Modeling of Turbulent Fluxes during Persistent Cold Air Pool Events in Salt Lake Valley, Utah

    Science.gov (United States)

    Ivey, C. E.; Sun, X.; Holmes, H.

    2017-12-01

    Land surface processes are important in meteorology and climate research since they control the partitioning of surface energy and water exchange at the earth's surface. The surface layer is coupled to the planetary boundary layer (PBL) by surface fluxes, which serve as sinks or sources of energy, moisture, momentum, and atmospheric pollutants. Quantifying the surface heat and momentum fluxes at the land-atmosphere interface, especially for different surface land cover types, is important because they can further influence the atmospheric dynamics, vertical mixing, and transport processes that impact local, regional, and global climate. A cold air pool (CAP) forms when a topographic depression (i.e., valley) fills with cold air, where the air in the stagnant layer is colder than the air aloft. Insufficient surface heating, which is not able to sufficiently erode the temperature inversion that forms during the nighttime stable boundary layer, can lead to the formation of persistent CAPs during wintertime. These persistent CAPs can last for days, or even weeks, and are associated with increased air pollution concentrations. Thus, realistic simulations of the land-atmosphere exchange are meaningful to achieve improved predictions of the accumulation, transport, and dispersion of air pollution concentrations. The focus of this presentation is on observations and modeling results using turbulence data collected in Salt Lake Valley, Utah during the 2010-2011 wintertime Persistent Cold Air Pool Study (PCAPS). Turbulent fluxes and the surface energy balance over seven land use types are quantified. The urban site has an energy balance ratio (EBR) larger than one (1.276). Negative Bowen ratio (-0.070) is found at the cropland site. In addition to turbulence observations, half-hourly WRF simulated net radiation, latent heat, sensible heat, ground heat fluxes during one persistent CAP event are evaluated using the PCAPS observations. The results show that sensible and latent

  6. THE DEPENDENCE OF HEAT CONSUMPTION ON THE DYNAMICS OF EXTERNAL AIR TEMPERATURE DURING COLD SNAP PERIODS

    Directory of Open Access Journals (Sweden)

    Rymarov Andrey Georgievich

    2014-09-01

    Full Text Available The dynamics of outdoor temperature variations during the cold period of the year influences the operation of the systems providing the required microclimate in the premises, which may be subject to automation systems that affects the IQ of a building, it is important to note that in the last decade there has been a growth in the participation of intelligent technologies in the formation of a microclimate of buildings. Studying the microclimate quality in terms of energy consumption of the premises and the building considers climate variability and outdoor air pollution, which is connected with the economic aspects of energy efficiency and productivity, and health of workers, as a short-term temperature fall in the premises has harmful consequences. Low outdoor temperatures dry the air in the premises that requires accounting for climate control equipment and, if necessary, the personal account of its work. Excess heat in the premises, including office equipment, corrects the temperature conditions, which reduces the adverse effect of cold snap.

  7. Črna Jama as a cold air trap cave within Postojna Cave, Slovenia

    Science.gov (United States)

    Šebela, Stanka; Turk, Janez

    2017-10-01

    Črna Jama is the coldest section of cave within the Postojna Cave System. Mean annual air temperatures at the Črna Jama 2 site are 5.6 °C (2015) and 5.7 °C (2016), and at the Črna Jama 3 site 7.1 °C (2015) and 7.2 (2016), whereas the mean external air temperature was 10.3 °C (2015) and 10.0 °C (2016). In Lepe Jame, the passage most heavily visited by tourists, the mean cave-air temperature is 10.7 °C (2014-2017). Črna Jama exhibits winter and summer temperature regimes. During warm periods (Tcave Tout), ventilation takes place and dense, cold, outside air sinks into Črna Jama because of the favourable cave entrance morphology. Recent Črna Jama air temperature data (2014-2017) indicate a < 0.5 °C higher temperature than that recorded in historical data since 1933. Črna Jama is the most appropriate place within the Postojna Cave System to study long-term climatic changes. There are hardly any tourist visits to the cave, and human impacts on the cave climate are essentially reduced.

  8. Simulation of a Novel Single-column Cryogenic Air Separation Process Using LNG Cold Energy

    Science.gov (United States)

    Jieyu, Zheng; Yanzhong, Li; Guangpeng, Li; Biao, Si

    In this paper, a novel single-column air separation process is proposed with the implementation of heat pump technique and introduction of LNG coldenergy. The proposed process is verifiedand optimized through simulation on the Aspen Hysys® platform. Simulation results reveal that thepower consumption per unit mass of liquid productis around 0.218 kWh/kg, and the total exergy efficiency of the systemis 0.575. According to the latest literatures, an energy saving of 39.1% is achieved compared with those using conventional double-column air separation units.The introduction of LNG cold energy is an effective way to increase the system efficiency.

  9. Keeping the Edge. Air Force Materiel Command Cold War Context (1945-1991). Volume 1: Command Lineage Scientific Achievement and Major Tenant Missions

    Science.gov (United States)

    2003-08-01

    Cambridge Research Laboratories AFCS Air Force Communications Service AFETR Air Force Eastern Test Range AFFDL Air Force Flight Dynamics Laboratory...Sacramento Air Logistics Center SMAMA Sacramento Air Materiel Area SOM Skidmore, Owings & Merrill SPACERAD Space Radiation Effects SPADATS Space...a unique post-World War II phenomenon that had a lasting effect —addressed here to illustrate some of the subtleties of the earliest Cold War years

  10. Coefficients of resistance to cold-air-drainage winds on a grass-covered slope

    International Nuclear Information System (INIS)

    Komoda, H.; Kobayashi, T.; Mori, M.; Kaneko, T.

    2006-01-01

    The cold-air-drainage (CAD) wind is one of the most familiar local winds in Japan. It is driven by the surplus of density, or the deficit of potential temperature produced by radiative cooling in the surface air layer on a slope, and is resisted by the ground surface and the surrounding atmosphere. The coefficients of resistance of the ground surface and the surrounding atmosphere change with the CAD wind speed. The observations made on a grass-covered slope of Mt. Kuju showed that the resistance exerted by the surrounding atmosphere was much larger than that by the ground surface, and the sum of two coefficients of resistance decreased by one order of magnitude when the CAD wind speed exceeded some critical value

  11. Nosocomial outbreak of cryptosporidiosis in AIDS patients

    DEFF Research Database (Denmark)

    Ravn, Pernille; Lundgren, Jens Dilling; Kjaeldgaard, P

    1991-01-01

    OBJECTIVE--To describe a nosocomial outbreak of cryptosporidiosis during four months after June 1989. SETTING--A department of infectious diseases in Copenhagen, seeing about half the patients with AIDS in Denmark. SUBJECTS--73 HIV antibody negative subjects and 60 antibody positive subjects...... admitted as inpatients during the transmission period of the outbreak (20 June-14 August), of whom 18 (17 with AIDS, one with AIDS related complex), developed cryptosporidiosis. Two further HIV negative subjects (one departmental secretary, one visiting relative) developed cryptosporidiosis. MAIN OUTCOME...... out ice for cold drinks. The mean incubation time was at least 13 days-that is, twice that in HIV-negative patients. Of the 18 patients with AIDS who developed cryptosporidiosis, five recovered, two were symptomless carriers, three died of unrelated causes, and eight died after prolonged diarrhoea...

  12. Evaluating and managing Cold War era historic properties : the cultural significance of U.S. Air Force defensive radar systems.

    Energy Technology Data Exchange (ETDEWEB)

    Whorton, M.

    1999-01-20

    Aircraft and later missile radar early warning stations played an important role in the Cold War. They are associated with important technological, social, political, and military themes of the Cold War and are worthy of preservation. The scope and scale of these systems make physical preservation impractical, but the U.S. Air Force program of historical evaluation and documentation of these systems will provide valuable information to future generations studying this historic period.

  13. Inactivation of Staphylococcus aureus and Enterococcus faecalis by a direct-current, cold atmospheric-pressure air plasma microjet.

    Science.gov (United States)

    Tian, Ye; Sun, Peng; Wu, Haiyan; Bai, Na; Wang, Ruixue; Zhu, Weidong; Zhang, Jue; Liu, Fuxiang

    2010-07-01

    A direct-current, cold atmospheric-pressure air plasma microjet (PMJ) was performed to inactivate Staphylococcus aureus (S. aureus) and Enterococcus faecalis (E. faecalis) in air. The process of sterilization and morphology of bacteria was observed. We wish to know the possible inactivation mechanisms of PMJ and explore a potential application in dental and other temperature sensitive treatment. In this study, we employed a direct current, atmospheric pressure, cold air PMJ to inactivate bacterias. Scanning electron microscopy was employed to evaluate the morphology of S. aureus and showed rupture of cell walls after the plasma treatment and Optical emission spectrum (OES) were used to understand the possible inactivation mechanisms of PMJ. The inactivation rates could reach 100% in 5 min. When the distance between the exit nozzle of the PMJ device and Petri dish was extended from 1 cm to 3 cm, effective inactivation was also observed with a similar inactivation curve. The inactivation of bacteria is attributed to the abundant reactive oxygen and nitrogen species, as well as ultroviolet radiation in the plasma. Different life spans and defensibilities of these killing agents may hold the key to understanding the different inactivation curves at different treatment distances.

  14. Relationships of self-identified cold tolerance and cold-induced vasodilatation in the finger

    Science.gov (United States)

    Park, Joonhee; Lee, Joo-Young

    2016-04-01

    This study was conducted to investigate relationships of self-identified cold tolerance and cold-induced vasodilatation (CIVD) in the finger. Nine males and 34 females participated in the following 2 tests: a CIVD test and a self-reported survey. The CIVD test was conducted 30-min cold-water immersion (3.8 ± 0.3 °C) of the middle finger at an air temperature of 27.9 ± 0.1 °C. The self-reported questionnaire consisted of 28 questions about whole and local body cold and heat tolerances. By a cluster analysis on the survey results, the participants were divided into two groups: high self-identified cold tolerance (HSCT, n = 25) and low self-identified cold tolerance (LSCT, n = 18). LSCT had lower self-identified cold tolerance ( P cold or heat tolerance had relationships with cold tolerance index, T max, and amplitude ( P cold tolerance classified through a standardized survey could be a good index to predict physiological cold tolerance.

  15. Human cold stress of strong local-wind "Hijikawa-arashi" in Japan, based on the UTCI index and thermo-physiological responses

    Science.gov (United States)

    Ohashi, Yukitaka; Katsuta, Takumi; Tani, Haruka; Okabayashi, Taiki; Miyahara, Satoshi; Miyashita, Ryoji

    2018-03-01

    We investigated the cold stress caused by a strong local wind called "Hijikawa-arashi," through in situ vital measurements and the Universal Thermal Climate Index (UTCI). This wind is a very interesting winter phenomenon, localized in an area within 1 km of the seashore in Ozu City, Ehime Prefecture in Japan. When a strong Hijikawa-arashi (HA) occurred at 14-15 m s-1, the UTCI decreased to - 30 °C along the bridge where commuting residents are the most exposed to strong and cold winds. On the bridge, most participants in our experiment felt "very cold" or "extremely cold." The UTCI of HA can be predicted from a multiple regression equation using wind speed and air temperature. The cold HA wind is also harmful to human thermo-physiological responses. It leads to higher blood pressure and increased heart rate, both of which act as cardiovascular stress triggers. Increases of 6-10 mmHg and 3-6 bpm for every 10 °C reduction in UTCI were seen on all observational days, including HA and non-HA days. In fact, the participants' body skin temperatures decreased by approximately 1.2 to 1.7 °C for every 10 °C reduction in UTCI. Thus, the UTCI variation due to the HA outbreak corresponded well with the cold sensation and thermo-physiological responses in humans. This result suggests that daily UTCI monitoring enables the prediction of thermo-physiological responses to the HA cold stress.

  16. Inactivation of Staphylococcus aureus and Enterococcus faecalis by a direct-current, cold atmospheric-pressure air plasma microjet☆

    Science.gov (United States)

    Tian, Ye; Sun, Peng; Wu, Haiyan; Bai, Na; Wang, Ruixue; Zhu, Weidong; Zhang, Jue; Liu, Fuxiang

    2010-01-01

    Objective A direct-current, cold atmospheric-pressure air plasma microjet (PMJ) was performed to inactivate Staphylococcus aureus (S. aureus) and Enterococcus faecalis (E. faecalis) in air. The process of sterilization and morphology of bacteria was observed. We wish to know the possible inactivation mechanisms of PMJ and explore a potential application in dental and other temperature sensitive treatment. Methods In this study, we employed a direct current, atmospheric pressure, cold air PMJ to inactivate bacterias. Scanning electron microscopy was employed to evaluate the morphology of S. aureus and showed rupture of cell walls after the plasma treatment and Optical emission spectrum (OES) were used to understand the possible inactivation mechanisms of PMJ. Results The inactivation rates could reach 100% in 5 min. When the distance between the exit nozzle of the PMJ device and Petri dish was extended from 1 cm to 3 cm, effective inactivation was also observed with a similar inactivation curve. Conclusion The inactivation of bacteria is attributed to the abundant reactive oxygen and nitrogen species, as well as ultroviolet radiation in the plasma. Different life spans and defensibilities of these killing agents may hold the key to understanding the different inactivation curves at different treatment distances. PMID:23554639

  17. An international foodborne outbreak of shigellosis associated with a commercial airline.

    Science.gov (United States)

    Hedberg, C W; Levine, W C; White, K E; Carlson, R H; Winsor, D K; Cameron, D N; MacDonald, K L; Osterholm, M T

    1992-12-09

    To determine the source of an international outbreak of shigellosis associated with consumption of food served by a Minnesota-based airline. Cohort studies of players and staff of a Minnesota-based professional football team and passengers on flights with a confirmed case of outbreak-associated Shigella sonnei infection. Community- and industry-based studies conducted from October through November 1988. Sixty-five football team players and staff, and 725 airline passengers in the cohort studies. Twenty-one (32%) of 65 football players and staff developed shigellosis that was associated with consumption of cold sandwiches prepared at the airline flight kitchen (relative risk [RR], 17.1; 95% confidence interval [Cl], 2.4 to 120; P airline passengers, and flight attendants. Thirty (4.1%) of 725 passengers on 13 flights with confirmed cases had confirmed or probable shigellosis. Illness was associated with consumption of cold food items served on the flights and prepared by hand at the airline flight kitchen (RR, 5.7; 95% Cl, 1.4 to 23.5; P food items or elimination of these items from menus.

  18. Measurement of cytoplasmic Ca2+ concentration in Saccharomyces cerevisiae induced by air cold plasma

    Science.gov (United States)

    Xiaoyu, DONG

    2018-03-01

    In this study, a novel approach to measure the absolute cytoplasmic Ca2+ concentration ([Ca2+]cyt) using the Ca2+ indicator fluo-3 AM was established. The parameters associated with the probe fluo-3 AM were optimized to accurately determine fluorescence intensity from the Ca2+-bound probe. Using three optimized parameters (final concentration of 6 mM probe, incubation time of 135 min, loading probe before plasma treatment), the maximum fluorescence intensity (F max = 527.8 a.u.) and the minimum fluorescence intensity (F min = 63.8 a.u.) were obtained in a saturated Ca2+ solution or a solution of lacking Ca2+. Correspondingly, the maximum [Ca2+]cyt induced by cold plasma was 1232.5 nM. Therefore, the Ca2+ indicator fluo-3 AM was successfully applied to measure the absolute [Ca2+]cyt in Saccharomyces cerevisiae stimulated by cold plasma at atmospheric air pressure.

  19. Research on frost formation in air source heat pump at cold-moist conditions in central-south China

    International Nuclear Information System (INIS)

    Gong, Guangcai; Tang, Jinchen; Lv, Dongyan; Wang, Hongjin

    2013-01-01

    Highlights: ►A dynamic evaporator model is built up. ► The model involves the ratio of the latent heat to sensible heat of wet air. ►A correlation considering d eq is shown below to predict frost accumulation: (M fr v 3 )/(Ψd eq 2 ) =((T a )/(T w ) ) 0.1 ((vτ)/(d eq ) ) 0.7 (l/(d eq ) ) 1.378 X a 1.228 . ►The changing ratio can characterize the early development of system performance. ►The changing ratio can characterize the early development of frost accumulation. -- Abstract: A dynamic evaporator model of air source heat pump (ASHP), considering the ratio of the latent heat to sensible heat of wet air, is presented to analyze the performance of ASHP under frosting. The performance parameters, such as the heating capacity, COP and the outlet temperature of compressor, are simulated with CYCLEPAD. Then a semi-empirical correlation that predicts frost accumulation on the air-side of fin-tube heat exchanger is developed with dimensionless analysis and also modified by a test conducted under cold-moist conditions in winter. In addition, eight influence factors are considered involving the ambient conditions and structures of heat exchanger, whose effects are analyzed as well. Among them, the equivalent diameter of air flow cross-section in fin-tube d eq is especially proposed. Lastly, the relationships between the ratio, the performance parameters and the frost accumulation are discussed in this paper, followed by an evaluation of an optimal defrosting time interval to improve the ASHP’s energy efficiency and operational reliability at cold-moist conditions in central-south China.

  20. Learning Large Lessons: The Evolving Roles of Ground Power and Air Power in the Post-Cold War Era. Executive Summary

    National Research Council Canada - National Science Library

    Johnson, David E

    2007-01-01

    U.S. post-Cold War military operations have witnessed a shift in the relative roles of ground power and air power in war fighting, but the joint war fighting potential of this shift is not being fully realized...

  1. Human cold stress of strong local-wind "Hijikawa-arashi" in Japan, based on the UTCI index and thermo-physiological responses.

    Science.gov (United States)

    Ohashi, Yukitaka; Katsuta, Takumi; Tani, Haruka; Okabayashi, Taiki; Miyahara, Satoshi; Miyashita, Ryoji

    2018-03-30

    We investigated the cold stress caused by a strong local wind called "Hijikawa-arashi," through in situ vital measurements and the Universal Thermal Climate Index (UTCI). This wind is a very interesting winter phenomenon, localized in an area within 1 km of the seashore in Ozu City, Ehime Prefecture in Japan. When a strong Hijikawa-arashi (HA) occurred at 14-15 m s -1 , the UTCI decreased to - 30 °C along the bridge where commuting residents are the most exposed to strong and cold winds. On the bridge, most participants in our experiment felt "very cold" or "extremely cold." The UTCI of HA can be predicted from a multiple regression equation using wind speed and air temperature. The cold HA wind is also harmful to human thermo-physiological responses. It leads to higher blood pressure and increased heart rate, both of which act as cardiovascular stress triggers. Increases of 6-10 mmHg and 3-6 bpm for every 10 °C reduction in UTCI were seen on all observational days, including HA and non-HA days. In fact, the participants' body skin temperatures decreased by approximately 1.2 to 1.7 °C for every 10 °C reduction in UTCI. Thus, the UTCI variation due to the HA outbreak corresponded well with the cold sensation and thermo-physiological responses in humans. This result suggests that daily UTCI monitoring enables the prediction of thermo-physiological responses to the HA cold stress.

  2. Factors determining dengue outbreak in Malaysia.

    Science.gov (United States)

    Ahmad, Rohani; Suzilah, Ismail; Wan Najdah, Wan Mohamad Ali; Topek, Omar; Mustafakamal, Ibrahim; Lee, Han Lim

    2018-01-01

    A large scale study was conducted to elucidate the true relationship among entomological, epidemiological and environmental factors that contributed to dengue outbreak in Malaysia. Two large areas (Selayang and Bandar Baru Bangi) were selected in this study based on five consecutive years of high dengue cases. Entomological data were collected using ovitraps where the number of larvae was used to reflect Aedes mosquito population size; followed by RT-PCR screening to detect and serotype dengue virus in mosquitoes. Notified cases, date of disease onset, and number and type of the interventions were used as epidemiological endpoint, while rainfall, temperature, relative humidity and air pollution index (API) were indicators for environmental data. The field study was conducted during 81 weeks of data collection. Correlation and Autoregressive Distributed Lag Model were used to determine the relationship. The study showed that, notified cases were indirectly related with the environmental data, but shifted one week, i.e. last 3 weeks positive PCR; last 4 weeks rainfall; last 3 weeks maximum relative humidity; last 3 weeks minimum and maximum temperature; and last 4 weeks air pollution index (API), respectively. Notified cases were also related with next week intervention, while conventional intervention only happened 4 weeks after larvae were found, indicating ample time for dengue transmission. Based on a significant relationship among the three factors (epidemiological, entomological and environmental), estimated Autoregressive Distributed Lag (ADL) model for both locations produced high accuracy 84.9% for Selayang and 84.1% for Bandar Baru Bangi in predicting the actual notified cases. Hence, such model can be used in forestalling dengue outbreak and acts as an early warning system. The existence of relationships among the entomological, epidemiological and environmental factors can be used to build an early warning system for the prediction of dengue outbreak so

  3. Design and cold-air test of single-stage uncooled turbine with high work output

    Science.gov (United States)

    Moffitt, T. P.; Szanca, E. M.; Whitney, W. J.; Behning, F. P.

    1980-01-01

    A solid version of a 50.8 cm single stage core turbine designed for high temperature was tested in cold air over a range of speed and pressure ratio. Design equivalent specific work was 76.84 J/g at an engine turbine tip speed of 579.1 m/sec. At design speed and pressure ratio, the total efficiency of the turbine was 88.6 percent, which is 0.6 point lower than the design value of 89.2 percent. The corresponding mass flow was 4.0 percent greater than design.

  4. Observations of an 11 September Sahelian Squall Line and Saharan Air Layer Outbreak during NAMMA-06

    Directory of Open Access Journals (Sweden)

    J. W. Smith

    2012-01-01

    Full Text Available The 2006 NASA-African Monsoon Multidisciplinary Analyses (NAMMA-06 field campaign examined a compact, low-level vortex embedded in the trough of an AEW between 9–12 September. The vortex triggered a squall line (SL in southeastern Senegal in the early morning of 11 September and became Tropical Depression 8 on 12 September. During this period, there was a Saharan Air Layer (SAL outbreak in northwestern Senegal and adjacent Atlantic Ocean waters in the proximity of the SL. Increases in aerosol optical thicknesses in Mbour, Senegal, high dewpoint depressions observed in the Kawsara and Dakar rawinsondes, and model back-trajectories suggest the SAL exists. The close proximity of this and SL suggests interaction through dust entrainment and precipitation invigoration.

  5. An outbreak of Serratia marcescens infection in a special-care baby unit of a community hospital in United Arab Emirates: the importance of the air conditioner duct as a nosocomial reservoir.

    Science.gov (United States)

    Uduman, S A; Farrukh, A S; Nath, K N R; Zuhair, M Y H; Ifrah, A; Khawla, A D; Sunita, P

    2002-11-01

    We report an outbreak of Serratia marcescens infection in a special-care baby unit (SCBU) of a university-affiliated community hospital in the United Arab Emirates. The outbreak involved 36 infants and lasted for 20 weeks. Seven of the colonized infants developed invasive illnesses in the form of bacteraemia (four cases), bacteraemic meningitis (two) and clinical sepsis (one). Three other term infants had purulent conjunctivitis. There were five deaths with an overall mortality of 14%. S. marcescens was cultured from airflow samples from the air conditioning (AC) which was the reservoir of infection in this outbreak. Elimination of the nosocomial source and outbreak containment were eventually achieved by specialized robotic cleaning of the entire AC duct system of the SCBU. Strict adherence to the infection control policies was reinforced to prevent transmission of cross-infection. Copyright 2002 The Hospital Infection Society

  6. [First ciguatera outbreak in Germany in 2012].

    Science.gov (United States)

    Friedemann, Miriam

    2016-12-01

    In November 2012, 23 cases of ciguatera with typical combinations of gastrointestinal and neurological symptoms occurred in Germany after consumption of imported tropical fish (Lutjanus spp.). A questionnaire was used to gather information on the disease course and fish consumption. All patients suffered from pathognomonic cold allodynia. Aside from two severe courses of illness, all other cases showed symptoms of moderate intensity. During a three-year follow-up, seven patients reported prolonged paresthesia for more than one year. Two of them reported further neuropathies over almost three years. This is the first time that long-term persistence of symptoms has been documented in detail. Outbreak cases were allocated to eight clusters in seven German cities. A further cluster was prevented by the successful recall of ciguatoxic fish. Three clusters were confirmed by the detection of ciguatoxin in samples of suspicious and recalled fish. An extrapolation on the basis of ciguatoxic samples revealed twenty prevented cases of ciguatera. Further officially unknown cases should be assumed. During the outbreak investigations, inadvertently falsely labelled fish species and fishing capture areas on import and retail level documents were observed. The ascertainment of cases and the outbreak investigations proved to be difficult due to inconsistent case reports to poisons centers, local health and veterinary authorities. In Germany, many physicians are unaware of the disease pattern of ciguatera and the risks caused by tropical fish. The occurrence of further outbreaks during the following years emphasizes the increasing significance of ciguatera in Germany.

  7. Numerical modeling of cold room's hinged door opening and closing processes

    Science.gov (United States)

    Carneiro, R.; Gaspar, P. D.; Silva, P. D.; Domingues, L. C.

    2016-06-01

    The need of rationalize energy consumption in agrifood industry has fasten the development of methodologies to improve the thermal and energy performances of cold rooms. This paper presents a three-dimensional (3D) transient Computational Fluid Dynamics (CFD) modelling of a cold room to evaluate the air infiltration rate through hinged doors. A species transport model is used for modelling the tracer gas concentration decay technique. Numerical predictions indicate that air temperature difference between spaces affects the air infiltration. For this case study, the infiltration rate increases 0.016 m3 s-1 per K of air temperature difference. The knowledge about the evolution of air infiltration during door opening/closing times allows to draw some conclusions about its influence on the air conditions inside the cold room, as well as to suggest best practices and simple technical improvements that can minimize air infiltration, and consequently improve thermal performance and energy consumption rationalization.

  8. Climate Teleconnections and Recent Patterns of Human and Animal Disease Outbreaks

    Science.gov (United States)

    Anyamba, Assaf; Linthicum, Kenneth J.; Small, Jennifer L.; Collins, Katherine M.; Tucker, Compton J.; Pak, Edwin W.; Britch, Seth C.; Eastman, James Ronald; Pinzon, Jorge E.; Russell, Kevin L.

    2011-01-01

    Recent clusters of outbreaks of mosquito-borne diseases (Rift Valley fever and chikungunya) in Africa and parts of the Indian Ocean islands illustrate how interannual climate variability influences the changing risk patterns of disease outbreaks. Extremes in rainfall (drought and flood) during the period 2004 - 2009 have privileged different disease vectors. Chikungunya outbreaks occurred during the severe drought from late 2004 to 2006 over coastal East Africa and the western Indian Ocean islands and in the later years India and Southeast Asia. The chikungunya pandemic was caused by a Central/East African genotype that appears to have been precipitated and then enhanced by global-scale and regional climate conditions in these regions. Outbreaks of Rift Valley fever occurred following excessive rainfall period from late 2006 to late 2007 in East Africa and Sudan, and then in 2008 - 2009 in Southern Africa. The shift in the outbreak patterns of Rift Valley fever from East Africa to Southern Africa followed a transition of the El Nino/Southern Oscillation (ENSO) phenomena from the warm El Nino phase (2006-2007) to the cold La Nina phase (2007-2009) and associated patterns of variability in the greater Indian Ocean basin that result in the displacement of the centres of above normal rainfall from Eastern to Southern Africa. Understanding the background patterns of climate variability both at global and regional scale and their impacts on ecological drivers of vector borne-diseases is critical in long-range planning of appropriate response and mitigation measures.

  9. Analysis and Modeling of Influenza Outbreaks as Driven by Weather

    Science.gov (United States)

    Thrastarson, H. T.; Teixeira, J.; Serman, E. A.; Parekh, A.; Yeo, E.

    2017-12-01

    Seasonal influenza outbreaks are a major source of illness, mortality and economic burden worldwide. Attributing what drives the seasonality of the outbreaks is still an unsettled problem. But in temperate regions absolute humidity conditions are a strong candidate (Shaman et al., 2010) and some studies have associated temperature conditions with influenza outbreaks. We use humidity and temperature data from NASA's AIRS (Atmospheric Infra-Red Sounder) instrument as well as data for influenza incidence in the US and South Africa to explore the connection between weather and influenza seasonality at different spatial scales. We also incorporate influenza surveillance data, satellite data and humidity forecasts into a numerical epidemiological prediction system. Our results give support for the role of local weather conditions as drivers of the seasonality of influenza in temperate regions. This can have implications for public health efforts where forecasting of the timing and intensity of influenza outbreaks has a great potential role (e.g., aiding management and organization of vaccines, drugs and other resources).

  10. Measles outbreak investigation in Guji zone of Oromia Region, Ethiopia.

    Science.gov (United States)

    Belda, Ketema; Tegegne, Ayesheshem Ademe; Mersha, Amare Mengistu; Bayenessagne, Mekonnen Getahun; Hussein, Ibrahim; Bezabeh, Belay

    2017-01-01

    Despite the increase of immunization coverage (administrative) of measles in the country, there are widespread outbreaks of measles. In this respect, we investigated one of the outbreaks that occurred in hard to reach kebeles of Guji Zone, Oromia region, to identify the contributing factors that lead to the protracted outbreak of measles. We used a cross-sectional study design to investigate a measles outbreak in Guji zone, Oromia region. Data entry and analysis was performed using EPI-Info version 7.1.0.6 and MS-Microsoft Excel. In three months' time a total of 1059 suspected cases and two deaths were reported from 9 woredas affected by a measles outbreak in Guji zone. The cumulative attack rate of 81/100,000 population and case fatality ratio of 0.2% was recorded. Of these, 821 (77.5%) cases were measles vaccine. Although, all age groups were affected under five years old were more affected 495 (48%) than any other age groups. In response to the outbreak, an outbreak response immunization was organized at the 11th week of the epidemic, when the epidemic curve started to decline. 6 months to14 years old were targeted for outbreak response immunization and the overall coverage was 97 % (range: 90-103%). Case management with vitamin A supplementation, active case search, and health education was some of the activities carried out to curb the outbreak. We conclude that low routine immunization coverage in conjunction with low access to routine immunization in hard to reach areas, low community awareness in utilization of immunization service, inadequate cold chain management and delivery of a potent vaccine in hard to reach woredas/kebeles were likely contributed to the outbreak that's triggered a broad spread epidemic affecting mostly children without any vaccination. We also figured that the case-based surveillance lacks sensitivity and timely confirmation of the outbreak, which as a result outbreak response immunization were delayed. We recommend establishing

  11. Assessing the environmental health relevance of cooling towers--a systematic review of legionellosis outbreaks.

    Science.gov (United States)

    Walser, Sandra M; Gerstner, Doris G; Brenner, Bernhard; Höller, Christiane; Liebl, Bernhard; Herr, Caroline E W

    2014-03-01

    Bioaerosols from cooling towers are often suspected to cause community-acquired legionellosis outbreaks. Although Legionella infections can mostly be assigned to the emission sources, uncertainty exists about the release and distribution into the air, the occurrence of the respirable virulent form and the level of the infective concentration. Our study aimed to evaluate studies on legionellosis outbreaks attributed to cooling towers published within the last 11 years by means of a systematic review of the literature. 19 legionellosis outbreaks were identified affecting 12 countries. Recurring events were observed in Spain and Great Britain. In total, 1609 confirmed cases of legionellosis and a case-fatality rate of approximately 6% were reported. Duration of outbreaks was 65 days on average. For diagnosis the urinary antigen test was mainly used. Age, smoking, male sex and underlying diseases (diabetes, immunodeficiency) could be confirmed as risk factors. Smoking and underlying diseases were the most frequent risk factors associated with legionellosis in 11 and 10 of the 19 studies, respectively. The meteorological conditions varied strongly. Several studies reported a temporal association of outbreaks with inadequate maintenance of the cooling systems. A match of clinical and environmental isolates by serotyping and/or molecular subtyping could be confirmed in 84% of outbreaks. Legionella-contaminated cooling towers as environmental trigger, in particular in the neighbourhood of susceptible individuals, can cause severe health problems and even death. To prevent and control Legionella contamination of cooling towers, maintenance actions should focus on low-emission cleaning procedures of cooling towers combined with control measurements of water and air samples. Procedures allowing rapid detection and risk assessment in the case of outbreaks are essential for adequate public health measures. Systematic registration of cooling towers will facilitate the

  12. Fitting outbreak models to data from many small norovirus outbreaks

    Directory of Open Access Journals (Sweden)

    Eamon B. O’Dea

    2014-03-01

    Full Text Available Infectious disease often occurs in small, independent outbreaks in populations with varying characteristics. Each outbreak by itself may provide too little information for accurate estimation of epidemic model parameters. Here we show that using standard stochastic epidemic models for each outbreak and allowing parameters to vary between outbreaks according to a linear predictor leads to a generalized linear model that accurately estimates parameters from many small and diverse outbreaks. By estimating initial growth rates in addition to transmission rates, we are able to characterize variation in numbers of initially susceptible individuals or contact patterns between outbreaks. With simulation, we find that the estimates are fairly robust to the data being collected at discrete intervals and imputation of about half of all infectious periods. We apply the method by fitting data from 75 norovirus outbreaks in health-care settings. Our baseline regression estimates are 0.0037 transmissions per infective-susceptible day, an initial growth rate of 0.27 transmissions per infective day, and a symptomatic period of 3.35 days. Outbreaks in long-term-care facilities had significantly higher transmission and initial growth rates than outbreaks in hospitals.

  13. The 2012 dengue outbreak in Madeira: exploring the origins.

    Science.gov (United States)

    Wilder-Smith, A; Quam, M; Sessions, O; Rocklov, J; Liu-Helmersson, J; Franco, L; Khan, K

    2014-02-27

    In 2012, Madeira reported its first major outbreak of dengue. To identify the origin of the imported dengue virus, we investigated the interconnectivity via air travel between dengue-endemic countries and Madeira, and compared available sequences against GenBank. There were 22,948 air travellers to Madeira in 2012, originating from twenty-nine dengue-endemic countries; 89.6% of these international travellers originated from Venezuela and Brazil. We developed an importation index that takes into account both travel volume and the extent of dengue incidence in the country of origin. Venezuela and Brazil had by far the highest importation indices compared with all other dengue-endemic countries. The importation index for Venezuela was twice as high as that for Brazil. When taking into account seasonality in the months preceding the onset of the Madeira outbreak, this index was even seven times higher for Venezuela than for Brazil during this time. Dengue sequencing shows that the virus responsible for the Madeira outbreak was most closely related to viruses circulating in Venezuela, Brazil and Columbia. Applying the importation index, Venezuela was identified as the most likely origin of importation of dengue virus via travellers to Madeira. We propose that the importation index is a new additional tool that can help to identify and anticipate the most probable country of origin for importation of dengue into currently non-endemic countries.

  14. Thermo-fluid-dynamic modelling of a cold store for cheese maturation

    Directory of Open Access Journals (Sweden)

    Ferruccio Giametta

    2013-03-01

    Full Text Available In this study, drying tests on fresh cheeses were carried out in a cold store equipped with a Munters MG90 dehumidifier that controls the humidity of the room air. In this system, the condensation/drainage stage is omitted since the humid room air is directed out of the cold store (process air and the dried air is introduced by the dehumidifier inside the cold store. Eight air temperature probes were introduced in the store; two probes (HOBO U12-012, 1 HOBO – Onset Computer Corporation, Cape Cod, MA, USA were also introduced and used to measure relative humidity and temperature together with an anemometer to analyse any changes in thermal and fluid dynamics in the cell environment. COMSOL multiphysics software (Comsol Group, Stockolm, Sweden was used to simulate the store environment based on the finite elements method. This allowed us to compare and discuss the experimental data collected and the results obtained by the thermo- fluid-dynamic simulation.

  15. A numerical study of the effect of vent flow angle on the heat transfer rate from a cold window with a below-window hot-air vent

    Energy Technology Data Exchange (ETDEWEB)

    Oosthuizen, P.H. [Queen' s Univ., Kingston, ON (Canada). Dept. of Mechanical and Materials Engineering

    2010-07-01

    This study investigated the effects of the discharge angle on air leaving a hot air vent mounted below a window. The window was represented by a plane isothermal section recessed into a wall and was colder than air in the rest of the room. The vent was placed against the wall and had a uniform discharge velocity. Flow was assumed to be steady. Both laminar and turbulent flows were evaluated using a commercial computational fluid dynamics (CFD) simulation tool. A k-epsilon turbulence model was used to determine turbulent flow calculations. The study determined the Rayleigh number based on window height, the Reynolds number based on the vent discharge velocity, the angle of the vent discharge flow, the Prandtl number, and dimensionless vent discharge temperature differences. The study showed that a relatively thin layer of cold air adjacent to the floor is present at high Rayleigh numbers, where the downward natural convective flow over the window dominates the overall flow. At low Rayleigh numbers, the cold air flows upward towards the ceiling and temperatures in the room are nearly uniform. 47 refs., 11 figs.

  16. Recommendations to Improve Employee Thermal Comfort When Working in 40°F Refrigerated Cold Rooms.

    Science.gov (United States)

    Ceballos, Diana; Mead, Kenneth; Ramsey, Jessica

    2015-01-01

    Cold rooms are commonly used for food storage and preparation, and are usually kept around 40°F following food safety guidelines. Some food preparation employees may spend 8 or more hours inside cold rooms. These employees may not be aware of the risks associated with mildly cold temperatures, dampness, and limited ventilation. We performed an evaluation of cold rooms at an airline catering facility because of concerns with exposure to cold temperatures. We spoke with and observed employees in two cold rooms, reviewed daily temperature logs, evaluated employee's physical activity, work/rest schedule, and protective clothing. We measured temperature, percent relative humidity, and air velocities at different work stations inside the cold rooms. We concluded that thermal comfort concerns perceived by cold room employees may have been the result of air drafts at their workstations, insufficient use of personal protective equipment due to dexterity concerns, work practices, and lack of knowledge about good health and safety practices in cold rooms. These moderately cold work conditions with low air velocities are not well covered in current occupational health and safety guidelines, and wind chill calculations do not apply. We provide practical recommendations to improve thermal comfort of cold room employees. Engineering control recommendations include the redesigning of air deflectors and installing of suspended baffles. Administrative controls include the changing out of wet clothing, providing hand warmers outside of cold rooms, and educating employees on cold stress. We also recommended providing more options on personal protective equipment. However, there is a need for guidelines and educational materials tailored to employees in moderately cold environments to improve thermal comfort and minimize health and safety problems.

  17. Friction and wear properties of Ti6Al4V/WC-Co in cold atmospheric plasma jet

    International Nuclear Information System (INIS)

    Xu Wenji; Liu Xin; Song Jinlong; Wu Libo; Sun Jing

    2012-01-01

    Highlights: ► Cold plasma jet can effectively reduce the friction coefficients of Ti6Al4V/WC-Co friction pairs. ► Cold plasma jet can easily form nitrides on the surface of Ti6Al4V and on new surfaces generated by tool wear. ► The nitrides can reduce the friction coefficients and protect the friction surface. - Abstract: The friction and wear properties of Ti6Al4V/WC-Co friction pair were studied using an autonomous atmospheric pressure bare electrode cold plasma jet generating device and block-on-ring friction/wear tester, respectively. The study was conducted under air, air jet, nitrogen jet, air cold plasma jet, and nitrogen cold plasma jet atmospheres. Both nitrogen cold and air cold plasma jets effectively reduced the friction coefficients of the friction pairs and decreased friction temperature. The friction coefficient in the nitrogen cold plasma jet decreased to almost 60% compared with that in the air. The scanning electron microscope, energy-dispersive X-ray spectroscope, and X-ray diffraction analyses illustrated that adhesive wear was relieved and the friction surfaces of Ti6Al4V were smoother, both in the nitrogen cold and air cold plasma jets. The roughness value R a of the Ti6Al4V friction surfaces can reach 1.107 μm. A large number of nitrogen particles in the ionic and excited states contained by cold plasma jets reacts easily on the friction surface to produce a large amount of nitrides, which can excellently reduce the wear of Ti6Al4V/WC-Co friction pairs in real-time.

  18. Cold source economic study

    International Nuclear Information System (INIS)

    Fuster, Serge.

    1975-01-01

    This computer code is intended for the statement of the general economic balance resulting from using a given cold source. The balance includes the investments needed for constructing the various materials, and also production balances resulting from their utilization. The case of either using an open circuit condenser on sea or river, or using air cooling systems with closed circuits or as auxiliaries can be dealt with. The program can be used to optimize the characteristics of the various parts of the cold source. The performance of the various materials can be evaluated for a given situation from using very full, precise economic balances, these materials can also be classified according to their possible uses, the outer constraints being taken into account (limits for heat disposal into rivers or seas, water temperature, air temperature). Technical choices whose economic consequences are important have been such clarified [fr

  19. Cold plasma inactivates salmonella on grape tomatoes in a commercial PET plastic container without affecting quality

    Science.gov (United States)

    Introduction: The number of outbreaks of foodborne illnesses associated with the consumption of fresh tomatoes has increased. Little research has been conducted on the effects of direct treatment of cold plasma (CP) on the microbial decontamination and preservation of bulk tomatoes packaged in comme...

  20. Cold recovery during regasification of LNG part one: Cold utilization far from the regasification facility

    International Nuclear Information System (INIS)

    La Rocca, Vincenzo

    2010-01-01

    The paper deals with cold recovery during LNG regasification. The applications analyzed pertain to the use in deep freezing agro food industry and in space air conditioning facilities in commercial sector (Supermarkets and Hypermarkets) of cold recovered from the regasification process. A modular LNG regasification unit is proposed having the regasification capacity of 2 BCM/year of gas and it is based on use of a Power Cycle working with Ethane, this unit allows operation of cold energy transfer, contained in LNG to be regasified, in a range of temperatures suitable for multipurpose use of cold, reducing regasification process irreversibility. Some electric energy is produced by the Power Cycle, but the purpose of the modular unit is to deliver cold suitable for industrial and commercial use in the proper temperature range utilizing Carbon dioxide as secondary fluid to transfer cold from regasification site to far end users. The subject is divided in two papers: this paper deals with facilities delivering cold released during LNG regasification and related pipeline facilities to transfer cold at far end users while the other paper pertains to analysis of end users applications. Results of a detailed thermodynamic and economic analysis demonstrate the suitability of the proposal.

  1. Disease Outbreak News

    Science.gov (United States)

    ... MERS-CoV) Pandemic (H1N1) 2009 Influenza at the Human-Animal Interface (HAI) Related documents WHO outbreak communication guide 2008 WHO outbreak communications guidelines Outbreak communication: ...

  2. Disneyland Measles Outbreak

    OpenAIRE

    Palladino, Erica

    2015-01-01

    This media information sheet analyzes print and online coverage of the 2015 Disneyland measles outbreak. The frameworks that the media used to report on the outbreak presented vaccination as the only viable option from preventing the spread of measles. Reporting also failed to mention that the 2015 Disneyland measles outbreak was smaller than U.S. measles outbreaks in 2013 and 2014.

  3. Whole-genome Sequencing Used to Investigate a Nationwide Outbreak of Listeriosis Caused by Ready-to-eat Delicatessen Meat, Denmark, 2014

    DEFF Research Database (Denmark)

    Kvistholm Jensen, Anne; Nielsen, Eva Møller; Björkman, Jonas Torgny

    2016-01-01

    patients' food and clinical histories. Food production facilities were inspected and sampled, and we performed trace-back/trace-forward of food delivery chains. In total, 41 cases were identified; 17 deaths occurred (41%). An isolate from a delicatessen meat (spiced meat roll) from company A was identical...... traced and recalled from >6000 food establishments, after which the outbreak ended. Ready-to-eat spiced meat roll from a single production facility caused this outbreak. The product, served sliced and cold, is popular among the elderly; serving it at hospitals probably contributed to the high case...

  4. Cold acclimation and cognitive performance: A review.

    Science.gov (United States)

    Jones, Douglas M; Bailey, Stephen P; Roelands, Bart; Buono, Michael J; Meeusen, Romain

    2017-12-01

    Athletes, occupational workers, and military personnel experience cold temperatures through cold air exposure or cold water immersion, both of which impair cognitive performance. Prior work has shown that neurophysiological pathways may be sensitive to the effects of temperature acclimation and, therefore, cold acclimation may be a potential strategy to attenuate cold-induced cognitive impairments for populations that are frequently exposed to cold environments. This review provides an overview of studies that examine repeated cold stress, cold acclimation, and measurements of cognitive performance to determine whether or not cold acclimation provides beneficial protection against cold-induced cognitive performance decrements. Studies included in this review assessed cognitive measures of reaction time, attention, logical reasoning, information processing, and memory. Repeated cold stress, with or without evidence of cold acclimation, appears to offer no added benefit of improving cognitive performance. However, research in this area is greatly lacking and, therefore, it is difficult to draw any definitive conclusions regarding the use of cold acclimation to improve cognitive performance during subsequent cold exposures. Given the current state of minimal knowledge on this topic, athletes, occupational workers, and military commands looking to specifically enhance cognitive performance in cold environments would likely not be advised to spend the time and effort required to become acclimated to cold. However, as more knowledge becomes available in this area, recommendations may change. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. An analysis of warm pool and cold tongue El Ninos: air-sea coupling processes, global influences, and recent trends

    Energy Technology Data Exchange (ETDEWEB)

    Hu, Zeng-Zhen; Kumar, Arun; Wang, Wanqiu [NCEP/NWS/NOAA, Climate Prediction Center, Camp Springs, MD (United States); Jha, Bhaskar; Huang, Boyin [NCEP/NWS/NOAA, Climate Prediction Center, Camp Springs, MD (United States); Wyle Information Systems, Camp Springs, MD (United States); Huang, Bohua [George Mason University, Department of Atmospheric, Oceanic, and Earth Sciences, College of Science, Fairfax, VA (United States); Center for Ocean-Land-Atmosphere Studies, Calverton, MD (United States)

    2012-05-15

    The differences in tropical air-sea interactions and global climate connection as well as the hindcast skills for the warm pool (WP) and cold tongue (CT) El Ninos are investigated based on observed, (re)analyzed, and model hindcast data. The robustness of observed global climate connection is established from the model simulations. Lastly, variations of atmosphere and ocean conditions in the recent decades, and their possible connection with the frequency increase of the WP El Nino are discussed. Consistent with previous results, our individual case study and composite results suggest that stronger (weaker) and more eastward extended (westward confined) westerly wind along the equatorial Pacific in early months of a year is associated with active (suppressed) air-sea interaction over the cold tongue/the Intertropical Convergence Zone complex, as well as more (less) intensive oceanic thermocline feedback, favoring the CT (WP) El Nino development. The preceding westerly wind signal and air-sea interaction differences may be responsible for the predication skill difference with higher (lower) overall hindcast skill for the CT (WP) El Nino in the Climate Forecast System of National Centers for Environmental Prediction. Our model experiments show that, in addition to the tropics, the eastern Pacific, North America and North Atlantic are the major regions having robust climate differences between the CT and WP El Ninos. Nevertheless, the climate contrasts seem not robust over the Eurasian continent. Also, the frequency increase of the WP El Nino in the recent decades may not be directly connected with the linear trend of the tropical climate. (orig.)

  6. Cold atmospheric air plasma sterilization against spores and other microorganisms of clinical interest.

    Science.gov (United States)

    Klämpfl, Tobias G; Isbary, Georg; Shimizu, Tetsuji; Li, Yang-Fang; Zimmermann, Julia L; Stolz, Wilhelm; Schlegel, Jürgen; Morfill, Gregor E; Schmidt, Hans-Ulrich

    2012-08-01

    Physical cold atmospheric surface microdischarge (SMD) plasma operating in ambient air has promising properties for the sterilization of sensitive medical devices where conventional methods are not applicable. Furthermore, SMD plasma could revolutionize the field of disinfection at health care facilities. The antimicrobial effects on Gram-negative and Gram-positive bacteria of clinical relevance, as well as the fungus Candida albicans, were tested. Thirty seconds of plasma treatment led to a 4 to 6 log(10) CFU reduction on agar plates. C. albicans was the hardest to inactivate. The sterilizing effect on standard bioindicators (bacterial endospores) was evaluated on dry test specimens that were wrapped in Tyvek coupons. The experimental D(23)(°)(C) values for Bacillus subtilis, Bacillus pumilus, Bacillus atrophaeus, and Geobacillus stearothermophilus were determined as 0.3 min, 0.5 min, 0.6 min, and 0.9 min, respectively. These decimal reduction times (D values) are distinctly lower than D values obtained with other reference methods. Importantly, the high inactivation rate was independent of the material of the test specimen. Possible inactivation mechanisms for relevant microorganisms are briefly discussed, emphasizing the important role of neutral reactive plasma species and pointing to recent diagnostic methods that will contribute to a better understanding of the strong biocidal effect of SMD air plasma.

  7. Serum concentrations of thyroid and adrenal hormones and TSH in men after repeated 1 h-stays in a cold room.

    Science.gov (United States)

    Korhonen, I; Hassi, J; Leppäluoto, J

    2001-11-01

    We exposed six healthy men to 1-h cold air (10 degrees C) daily for 11 days and measured adrenal and thyroid hormones and TSH in serum before and after the cold air exposure on days 0, 5 and 10. We observed that on days 0, 5 and 10 the resting levels and the levels after the cold exposure in serum adrenaline, thyroid hormones and TSH did not significantly change, whereas the serum noradrenaline levels showed a significant 2.2-2.5-fold increase in response to the cold air exposures. The increases were similar indicating that the subjects did not show signs of habituation in their noradrenaline responses. Therefore the 1-h cold air exposure is not sufficiently intensive to reduce the cold-induced sympathetic response.

  8. Convective Cold Pool Structure and Boundary Layer Recovery in DYNAMO

    Science.gov (United States)

    Savarin, A.; Chen, S. S.; Kerns, B. W.; Lee, C.; Jorgensen, D. P.

    2012-12-01

    One of the key factors controlling convective cloud systems in the Madden-Julian Oscillation (MJO) over the tropical Indian Ocean is the property of the atmospheric boundary layer. Convective downdrafts and precipitation from the cloud systems produce cold pools in the boundary layer, which can inhibit subsequent development of convection. The recovery time is the time it takes for the boundary layer to return to pre convective conditions. It may affect the variability of the convection on various time scales during the initiation of MJO. This study examines the convective cold pool structure and boundary layer recovery using the NOAA WP-3D aircraft observations, include the flight-level, Doppler radar, and GPS dropsonde data, collected during the Dynamics of MJO (DYNAMO) field campaign from November-December 2011. The depth and strength of convective cold pools are defined by the negative buoyancy, which can be computed from the dropsonde data. Convective downdraft can be affected by environmental water vapor due to entrainment. Mid-level dry air observed during the convectively suppressed phase of MJO seems to enhance convective downdraft, making the cold pools stronger and deeper. Recovery of the cold pools in the boundary layer is determined by the strength and depth of the cold pools and also the air-sea heat and moisture fluxes. Given that the water vapor and surface winds are distinct for the convectively active and suppressed phases of MJO over the Indian Ocean, the aircraft data are stratified by the two different large-scale regimes of MJO. Preliminary results show that the strength and depth of the cold pools are inversely correlated with the surrounding mid-level moisture. During the convectively suppressed phase, the recovery time is ~5-20 hours in relative weak wind condition with small air-sea fluxes. The recovery time is generally less than 6 hours during the active phase of MJO with moist mid-levels and stronger surface wind and air-sea fluxes.

  9. Boundary-layer effects on cold fronts at a coastline

    Science.gov (United States)

    Garratt, J. R.

    1986-07-01

    The present note discusses one physical mechanism which may contribute to cold air channelling, manifest as a frontal bulge on a surface-analysis chart, in the coastal region of Victoria in southeast Australia. This involves the modification of boundary-layer air in both offshore (prefrontal) and onshore (postfrontal) flow, and the effect on cross-frontal thermal contrast. The problem is discussed in terms of a north-south-oriented cold front behaving as an atmospheric gravity current, propagating along an east-west-oriented coastline, in the presence of a prefrontal offshore stream.

  10. Air flow management in raised floor data centers

    CERN Document Server

    Arghode, Vaibhav K

    2016-01-01

    The Brief discuss primarily two aspects of air flow management in raised floor data centers. Firstly, cooling air delivery through perforated tiles will be examined and influence of the tile geometry on flow field development and hot air entrainment above perforated tiles will be discussed. Secondly, the use of cold aisle containment to physically separate hot and cold regions, and minimize hot and cold air mixing will be presented. Both experimental investigations and computational efforts are discussed and development of computational fluid dynamics (CFD) based models for simulating air flow in data centers is included. In addition, metrology tools for facility scale air velocity and temperature measurement, and air flow rate measurement through perforated floor tiles and server racks are examined and the authors present thermodynamics-based models to gauge the effectiveness and importance of air flow management schemes in data centers.

  11. [Salmonellosis outbreaks and the size and role of the Chilean State].

    Science.gov (United States)

    Fica, Alberto; Acosta, Gerardo; Dabanch, Jeannette; Perret, Cecilia; Torres, Marisa; López, Javier; Jofré, Leonor; Weitzel, Thomas

    2012-04-01

    During year 2011 two outbreaks of Salmonella infection captured media attention in the Metropolitan Area (MA) in Chile: one of typhoid fever associated to Salmonella serotype Typhi, and the other, of gastroenteritis related to Salmonella serotype Enteritidis, both with decreasing or stable rates in the previous years. The aim of this work is to analyze probable causes of their reemergence. Several government websites were searched looking for epidemiological data. Typhoid fever rates have declined to current values of 1 case per 100.000 habitants, a decreased associated to improvements in the human development index. The typhoid outbreak was associated to a predominant clone within the MA. The only risk factor identified was consumption of raw vegetables acquired in open fairs, but without identifying a common source. Despite improvements in disease notification and molecular epidemiology capabilities, this outbreak is coincidental with a reduced number of food inspection visits in the MA, probably explained by the limited personnel available for this task. In the case of Salmonella Enteritidis, rates have increased twice since 1998 (5.3 to 10.7 per 100.000 habitants) with an important increase in the number of outbreaks linked to this agent (7 to 31 annual outbreaks) since year 2005. Persistence of this problem is probably associated to the low surveillance of poultry farms made by the Chilean state, to the absence of a cold chain during collection, distribution and selling of eggs, and to the lack of an educational program directed to the population. The recent regulation that bans home-made mayonnaise in restaurant or fast food stores is an important advance that requires further evaluation. The persistence and reemergence of different kind of Salmonellosis in Chile suggests chronic problems on the size and role of the Chilean state regarding food safety.

  12. Norovirus outbreak associated with a hotel in the west of Ireland, 2006.

    Science.gov (United States)

    Michel, A; Fitzgerald, R; Whyte, D; Fitzgerald, A; Beggan, E; O'Connell, N; Greally, T

    2007-07-01

    An outbreak of gastrointestinal disease (nausea, vomiting or diarrhoea) occurred among a party of wedding guests, staff and other guests in a hotel in the west of Ireland, in October 2006. Upon notification, a multi-disciplinary outbreak control team was convened to investigate and control the outbreak. In all, 98 people were ascertained ill. The median duration of illness was 48 hours. The attack rate ranged between 48 and 85%. The hotel voluntarily notified health authorities and co-operated fully with investigation and control measures. Strict prevention and control measures were instituted promptly, including air ventilation, enhanced hand hygiene, isolation of cases, temporary "cooked food only", temporary alternative accommodation and specialised cleaning. Three cases of norovirus infection were laboratory-confirmed. There was no evidence of food- or water-borne transmission. Clinical and epidemiological findings indicated person-to-person transmission of norovirus. This report highlights the potential for large social gatherings to facilitate the spread of viral gastroenteritis by person-to-person transmission and via contaminated environment. Effective community management of this outbreak appears to have prevented its having an impact on local acute hospital services. The authors conclude that in addition to the existing national guidelines on the management of outbreaks of norovirus in healthcare settings, agreed guidelines for the management of norovirus outbreaks in the hotel and tourism industry are needed in Ireland.

  13. Potential application of glazed transpired collectors to space heating in cold climates

    International Nuclear Information System (INIS)

    Gao, Lixin; Bai, Hua; Mao, Shufeng

    2014-01-01

    Highlights: • A mathematical model for glazed transpired collectors (GTC) is developed. • Glazing results in optical loss, but it decreases convective heat loss effectively. • Thermal performance of GTC shows considerable improvement on flat-plate collectors. • GTC using recirculated air is applicable to space heating in cold climates. - Abstract: Although unglazed transpired collectors (UTC) succeed in industrial ventilation applications, solar fraction is very low when they are used in space heating in cold climates due to the lower exit air temperature. Considering the potential for glazed transpired collectors (GTC) using recirculated air for space heating applications in cold climates, a mathematical model is developed for predicting the thermal performance of GTC. Simulation results show that although glazing results in optical loss, it could decrease convective heat loss resulted from high crosswind velocities effectively. For a solar radiation of 400 W/m 2 , an ambient temperature of −10 °C, and a suction velocity of 0.01 m/s, the exit air temperature of GTC is higher than that of UTC for crosswind velocities exceeding 3.0 m/s. By comparison with a conventional flat-plate solar air collector operating under the same conditions, the thermal performance of GTC shows a significant improvement. For a five-storey hotel building located in the severe cold climate zone of China, case study shows that the annual solar fraction of the GTC-based solar air heating system is about 20%, which is two times higher than that of the flat-plate collector-based system and nearly nine times higher than that of the UTC-based system respectively. Hence, an enormous amount of energy will be saved with the application of GTC to space heating in cold climates

  14. Listeria monocytogenes in Fresh Produce: Outbreaks, Prevalence and Contamination Levels

    Directory of Open Access Journals (Sweden)

    Qi Zhu

    2017-03-01

    Full Text Available Listeria monocytogenes, a member of the genus Listeria, is widely distributed in agricultural environments, such as soil, manure and water. This organism is a recognized foodborne pathogenic bacterium that causes many diseases, from mild gastroenteritis to severe blood and/or central nervous system infections, as well as abortion in pregnant women. Generally, processed ready-to-eat and cold-stored meat and dairy products are considered high-risk foods for L. monocytogenes infections that cause human illness (listeriosis. However, recently, several listeriosis outbreaks have been linked to fresh produce contamination around the world. Additionally, many studies have detected L. monocytogenes in fresh produce samples and even in some minimally processed vegetables. Thus L. monocytogenes may contaminate fresh produce if present in the growing environment (soil and water. Prevention of biofilm formation is an important control measure to reduce the prevalence and survival of L. monocytogenes in growing environments and on fresh produce. This article specifically focuses on fresh produce–associated listeriosis outbreaks, prevalence in growing environments, contamination levels of fresh produce, and associated fresh produce safety challenges.

  15. Exploring the origin and potential for spread of the 2013 dengue outbreak in Luanda, Angola.

    Science.gov (United States)

    Sessions, October M; Khan, Kamran; Hou, Yan'an; Meltzer, Eyal; Quam, Mikkel; Schwartz, Eli; Gubler, Duane J; Wilder-Smith, Annelies

    2013-08-02

    Dengue in Africa is underreported. Simultaneous reports of travellers with dengue returning from Luanda, Angola, to six countries on four continents suggest that a major dengue outbreak is currently occurring in Angola, South West Africa. To identify the origin of the imported dengue virus, we sequenced the virus from Angola and investigated the interconnectivity via air travel between dengue-endemic countries and Angola. Our analyses show that the Angola outbreak was most likely caused by an endemic virus strain that had been circulating in West Africa for many years. We also show that Portugal and South Africa are most likely at the highest risk of importation of dengue from Angola due to the large number of air passengers between Angola and these countries.

  16. Study of exposure to cold stress and body physiological responses in auto mechanic employees in Hamadan city

    Directory of Open Access Journals (Sweden)

    Keivan Saedpanah

    2017-09-01

    Full Text Available Introduction: Continuous exposure to cold air is considered to be a hazardous agent in the workplace in cold seasons. This study aimed to determine the level of cold stress and relation with physiological responses in auto mechanic employees. Method: This cross-sectional study was conducted in the winter of 1395 on auto mechanic employees in Hamadan city. Physiological responses during daily activity were measured in accordance with ISO 9886 standard method. Environmental air measures like air temperature and air velocity were measured simultaneously and cold stress indexes were also determined. Data was analyzed using SPSS 21 software. Result: The result showed that mean wind chill index, equivalent chill temperature and required clothing insulation were 489.97±47.679 kcal/m2.h, 13.78± 1.869 0c and 2.04 ± 0.246 clo, respectively. According to the results of cold stress indexes, the studied employees are exposed to cold stress. Pearson correlation test showed that there are significant relationship between cold stress indexes with physiological responses (p<0.05, however, IREQ min showed more correlation than the others.  There is also a significant relationship between body fat percentage and deep temperature (p<0.05, r=0.314. Conclusion: The result confirmed that IREQ min index has high validity for estimation of cold stress among auto mechanic employees. Moreover, the increase of body fat percentage leads to an increase of cold tolerance power of employees.

  17. Field Performance of Inverter-Driven Heat Pumps in Cold Climates

    Energy Technology Data Exchange (ETDEWEB)

    Williamson, James [Consortium of Advanced Residential Buildings, Norwalk, CT (United States); Aldrich, Robb [Consortium of Advanced Residential Buildings, Norwalk, CT (United States)

    2015-08-19

    Traditionally, air-source heat pumps (ASHPs) have been used more often in warmer climates; however, some new ASHPs are gaining ground in colder areas. These systems operate at subzero (Fahrenheit) temperatures and many do not include backup electric resistance elements. There are still uncertainties, however, about capacity and efficiency in cold weather. Also, questions such as “how cold is too cold?” do not have clear answers. These uncertainties could lead to skepticism among homeowners; poor energy savings estimates; suboptimal system selection by heating, ventilating, and air-conditioning contractors; and inconsistent energy modeling. In an effort to better understand and characterize the heating performance of these units in cold climates, the U.S. Department of Energy Building America team, Consortium for Advanced Residential Buildings (CARB), monitored seven inverter-driven, ductless ASHPs across the Northeast. Operating data were collected for three Mitsubishi FE18 units, three Mitsubishi FE12 units, and one Fujitsu 15RLS2 unit. The intent of this research was to assess heat output, electricity consumption, and coefficients of performance (COPs) at various temperatures and load conditions. This assessment was accomplished with long- and short-term tests that measured power consumption; supply, return, and outdoor air temperatures; and airflow through the indoor fan coil.

  18. Randomized clinical study comparing Compeed (R) cold sore patch to acyclovir cream 5% in the treatment of herpes simplex labialis

    DEFF Research Database (Denmark)

    Karlsmark, T.; Goodman, J.J.; Drouault, Y.

    2008-01-01

    Background Hydrocolloid technology has been proven effective in treating dermal wounds. A previous study showed that a newly developed thin hydrocolloid patch [Compeed (R) cold sore patch (CSP)] provided multiple wound-healing benefits across all stages of a herpes simplex labialis (HSL) outbreak...

  19. Emerging Capripoxvirus disease outbreaks in Himachal Pradesh, a northern state of India.

    Science.gov (United States)

    Verma, S; Verma, L K; Gupta, V K; Katoch, V C; Dogra, V; Pal, B; Sharma, M

    2011-02-01

    Both sheep and goat pox are contagious viral diseases and affect small ruminants and are caused by sheep pox virus and goat pox virus respectively that belong to genus Capripoxvirus of Poxviridae family. Huge economic losses emanating from the disease outbreaks are the results of the wool and hide damage, subsequent production losses and also the morbidities and mortalities associated with the disease. This communication highlights clinico-epidemiological observations from the two sheep pox and one goat pox outbreaks. Grossly, multisystemic nodular lesions, mucopurulent nasal discharges and respiratory symptoms were observed in the affected animals. The morbidity, mortality and case fatality rates were 5.18%, 2.45% and 32.37%, respectively. Histopathological, haematological, molecular and serological techniques and also isolation of virus in embryonated chicken eggs were used for the diagnosis of the diseases. The spatial distribution of the disease signifies the role of common pasturelands used for grazing the animals while temporally all three outbreaks occurred in winters and were probably associated with cold stress and fodder scarcity. This is the first recorded report of Capripoxvirus infection in recent times and it highlights the disease as one of the emerging diseases in the northern state of Himachal Pradesh in India. © 2010 Blackwell Verlag GmbH.

  20. Study on heat collector of the solar system utilizing outdoor air. Experimental results in cases of cold and warm regions; Gaiki donyushiki solar system no shunetsubu ni kansuru kenkyu. Kanreichi to ondanchi ni okeru shunetsu jikken to kosatsu

    Energy Technology Data Exchange (ETDEWEB)

    Komano, S; Ebara, Y [OM Solar Association, Shizuoka (Japan); Wada, H [Wada Building Constructors Co. Ltd., Hokkaido (Japan)

    1996-10-27

    An experiment on heat collection was made in the heat collector of a solar system utilizing outdoor air in cold and warm regions. In this system, outdoor air is heated by the air circulation layer on the roof exposed to solar radiation. The heated air is supplied to the object space for heating and ventilation. In the experiment in a cold region, the heat collection characteristics can be adjusted by putting a baffle plate in the air duct according to the experiment of a glass heat collector. The heat collecting air layer on only the iron roof may leak or freeze in the region subject to coldness or heavy snowfall. Therefore, preheat forms the space of a garret, and the preheat temperature comparatively becomes low. The data in which the heat collection characteristics can be adjusted using only a glass heat collector is required corresponding to the regional situation. In the experiment in a warm region, an experiment was made inclusive of the preheat for which outdoor air is absorbed at the eaves. As a result, the heat collection characteristics of preheat were improved. Moreover, a heat collection temperature of about 60{degree}C was obtained on the heat collection surface including the preheat. 1 ref., 12 figs., 3 tabs.

  1. Characterization of Viral Load, Viability and Persistence of Influenza A Virus in Air and on Surfaces of Swine Production Facilities.

    Directory of Open Access Journals (Sweden)

    Victor Neira

    Full Text Available Indirect transmission of influenza A virus (IAV in swine is poorly understood and information is lacking on levels of environmental exposure encountered by swine and people during outbreaks of IAV in swine barns. We characterized viral load, viability and persistence of IAV in air and on surfaces during outbreaks in swine barns. IAV was detected in pigs, air and surfaces from five confirmed outbreaks with 48% (47/98 of oral fluid, 38% (32/84 of pen railing and 43% (35/82 of indoor air samples testing positive by IAV RT-PCR. IAV was isolated from air and oral fluids yielding a mixture of subtypes (H1N1, H1N2 and H3N2. Detection of IAV RNA from air was sustained during the outbreaks with maximum levels estimated between 7 and 11 days from reported onset. Our results indicate that during outbreaks of IAV in swine, aerosols and surfaces in barns contain significant levels of IAV potentially representing an exposure hazard to both swine and people.

  2. Measurements of temperature fluctuations in the mixing of hot and cold air jets

    International Nuclear Information System (INIS)

    Sumner, V.W.

    1977-03-01

    In order to assess the effect of the mixing of 'hot' and 'cold' jets of sodium on structures in the above-core region of the fast reactor, temperature fluctuations have been measured in an experiment consisting of a heated jet of air surrounded by six unheated jets. Temperature spectra obtained from the experiment showed no strong peaks or bands. In considering the effect of thermal cycling of the above-core structures, it is the higher strain values at low frequencies which will be more limiting than the smaller values at high frequencies, due to the nature of strain-lifetime curves. Thus the spectra have been summarised using a low-frequency level and a cut-off frequency at which this level has fallen by an order of magnitude. Attenuation of temperature fluctuations due to the high thermal conductivity of sodium or by boundary layer effects has been considered; however, in the low-frequency, high-energy region of the spectra, little attenuation can be expected. (author)

  3. Air-sea interactions during strong winter extratropical storms

    Science.gov (United States)

    Nelson, Jill; He, Ruoying; Warner, John C.; Bane, John

    2014-01-01

    A high-resolution, regional coupled atmosphere–ocean model is used to investigate strong air–sea interactions during a rapidly developing extratropical cyclone (ETC) off the east coast of the USA. In this two-way coupled system, surface momentum and heat fluxes derived from the Weather Research and Forecasting model and sea surface temperature (SST) from the Regional Ocean Modeling System are exchanged via the Model Coupling Toolkit. Comparisons are made between the modeled and observed wind velocity, sea level pressure, 10 m air temperature, and sea surface temperature time series, as well as a comparison between the model and one glider transect. Vertical profiles of modeled air temperature and winds in the marine atmospheric boundary layer and temperature variations in the upper ocean during a 3-day storm period are examined at various cross-shelf transects along the eastern seaboard. It is found that the air–sea interactions near the Gulf Stream are important for generating and sustaining the ETC. In particular, locally enhanced winds over a warm sea (relative to the land temperature) induce large surface heat fluxes which cool the upper ocean by up to 2 °C, mainly during the cold air outbreak period after the storm passage. Detailed heat budget analyses show the ocean-to-atmosphere heat flux dominates the upper ocean heat content variations. Results clearly show that dynamic air–sea interactions affecting momentum and buoyancy flux exchanges in ETCs need to be resolved accurately in a coupled atmosphere–ocean modeling framework.

  4. Dynamic model of counter flow air to air heat exchanger for comfort ventilation with condensation and frost formation

    DEFF Research Database (Denmark)

    Nielsen, Toke Rammer; Rose, Jørgen; Kragh, Jesper

    2009-01-01

    must be calculated under conditions with condensation and freezing. This article presents a dynamic model of a counter flow air to air heat exchanger taking into account condensation and freezing and melting of ice. The model is implemented in Simulink and results are compared to measurements......In cold climates heat recovery in the ventilation system is essential to reduce heating energy demand. Condensation and freezing occur often in efficient heat exchangers used in cold climates. To develop efficient heat exchangers and defrosting strategies for cold climates, heat and mass transfer...

  5. Detection of Coxiella burnetii in Ambient Air after a Large Q Fever Outbreak

    NARCIS (Netherlands)

    de Rooij, Myrna M T; Borlée, Floor; Smit, Lidwien A M; de Bruin, Arnout; Janse, Ingmar; Heederik, Dick J J; Wouters, Inge M

    One of the largest Q fever outbreaks ever occurred in the Netherlands from 2007-2010, with 25 fatalities among 4,026 notified cases. Airborne dispersion of Coxiella burnetii was suspected but not studied extensively at the time. We investigated temporal and spatial variation of Coxiella burnetii in

  6. A new conceptual cold-end design of boilers for coal-fired power plants with waste heat recovery

    International Nuclear Information System (INIS)

    Yang, Yongping; Xu, Cheng; Xu, Gang; Han, Yu; Fang, Yaxiong; Zhang, Dongke

    2015-01-01

    Highlights: • A new cold-end design of boilers for CFPPs with waste heat recovery is proposed. • Thermodynamic and economic analyses are quantitatively conducted. • Higher energy efficiency improvement and greater economic benefits are achieved. • Lower exergy destruction and better matched energy level are obtained. - Abstract: After conducting an in-depth analysis of the conventional boiler cold-end design for waste heat recovery, this work proposed a new conceptual boiler cold-end design integrated with the steam cycle in a 1000 MW CFPP, in which the preheating of air was divided into high-temperature air preheater (HTAP), main air preheater (MAP) and low-temperature air preheater (LTAP). The HTAP and an economizer were installed in separate flue ducts, and the low temperature economizer (LTE) was situated between the MAP and the LTAP in the main flue duct to heat the condensed water. In the proposed boiler cold-end design, the flue gas waste heat was not only used to heat condensed water, but also to further preheat the combustion air. The air temperature at the air-preheater outlet increases and part of the steam bleeds with high exergy can be saved, resulting in greater energy-savings and better economics. Results showed that, for a typical 1000 MW CFPP in China, using the proposed boiler cold-end design for waste heat recovery could produce 13.3 MW e additional net power output with a heat rate reduction of approximately 112.0 kJ/kW h and could yield a net benefit of up to $85.8 M per year, which is much greater than those of the conventional cases. Exergy destruction is also reduced from 49.9 MW th in the conventional boiler cold-end design to 39.6 MW th in the proposed design

  7. Nonthermal inactivation of norovirus surrogates on blueberries using atmospheric cold plasma.

    Science.gov (United States)

    Lacombe, Alison; Niemira, Brendan A; Gurtler, Joshua B; Sites, Joseph; Boyd, Glenn; Kingsley, David H; Li, Xinhui; Chen, Haiqiang

    2017-05-01

    Viruses are currently the leading cause of foodborne outbreaks, most of which are associated with foods consumed raw. Cold plasma (CP) is an emerging novel nonthermal technology that can be used to surface decontaminate foods. This study investigated CP technology for the nonthermal inactivation of human norovirus surrogates, Tulane virus (TV) and murine norovirus (MNV), on the surface of blueberries. Blueberries (5 g) were weighed into sterile 4 oz. glass jars and inoculated with TV, 5 log PFU/g. Samples were treated with atmospheric CP for 0, 15, 30, 45, and 60 s at a working distance of 7.5 cm with 4 cubic feet/minute (cfm) of CP jet. Temperature readings were taken with an infrared camera prior to, and immediately following, CP treatments. In order to establish the impact of air flow during CP treatment (4 cfm), an additional 7 cfm jet of room temperature air was introduced from a separate nozzle. The experiment was repeated with 90 and 120 s as additional treatment time points. Viral titers were measured immediately after each treatment with a plaque assay using LLC-MK2 cells (TV) or RAW 264.7 cells (MNV). TV was significantly reduced 1.5 PFU/g compared to the control after treatment time of 45s, which was achieved regardless of temperature conditions. With the addition of 7 cfm of ambient air, the maximum log reduction for TV was 3.5 log PFU/g after 120s of treatment. MNV was significantly reduced by 0.5 log PFU/g compare to the control at 15s, and further treatment of MNV with ambient air brought the log reduction to greater than 5 log PFU/g at 90 s of treatment (Fig. 3). These results demonstrate that CP viral inactivation does not rely on thermal inactivation, and is therefore nonthermal in nature. With further optimization, CP may be used by food processors as a means of nonthermal inactivation of foodborne viruses. Published by Elsevier Ltd.

  8. Climate teleconnections and recent patterns of human and animal disease outbreaks.

    Directory of Open Access Journals (Sweden)

    Assaf Anyamba

    2012-01-01

    Full Text Available Recent clusters of outbreaks of mosquito-borne diseases (Rift Valley fever and chikungunya in Africa and parts of the Indian Ocean islands illustrate how interannual climate variability influences the changing risk patterns of disease outbreaks. Although Rift Valley fever outbreaks have been known to follow periods of above-normal rainfall, the timing of the outbreak events has largely been unknown. Similarly, there is inadequate knowledge on climate drivers of chikungunya outbreaks. We analyze a variety of climate and satellite-derived vegetation measurements to explain the coupling between patterns of climate variability and disease outbreaks of Rift Valley fever and chikungunya.We derived a teleconnections map by correlating long-term monthly global precipitation data with the NINO3.4 sea surface temperature (SST anomaly index. This map identifies regional hot-spots where rainfall variability may have an influence on the ecology of vector borne disease. Among the regions are Eastern and Southern Africa where outbreaks of chikungunya and Rift Valley fever occurred 2004-2009. Chikungunya and Rift Valley fever case locations were mapped to corresponding climate data anomalies to understand associations between specific anomaly patterns in ecological and climate variables and disease outbreak patterns through space and time. From these maps we explored associations among Rift Valley fever disease occurrence locations and cumulative rainfall and vegetation index anomalies. We illustrated the time lag between the driving climate conditions and the timing of the first case of Rift Valley fever. Results showed that reported outbreaks of Rift Valley fever occurred after ∼3-4 months of sustained above-normal rainfall and associated green-up in vegetation, conditions ideal for Rift Valley fever mosquito vectors. For chikungunya we explored associations among surface air temperature, precipitation anomalies, and chikungunya outbreak locations. We found

  9. Experimental Results Obtained with Air Liquide Cold Compression System CERN LHC and SNS Projects

    CERN Document Server

    Delcayre, F; Hamber, F; Hilbert, B; Monneret, E; Toia, J L

    2006-01-01

    Large scale collider facilities will make intensive use of superconducting magnets, operating below 2.0 K. This dictates high‐capacity refrigeration systems operating below 2.0 K. These systems, making use of cryogenic centrifugal compressors in a series arrangement with room temperature screw compressors will be coupled to a refrigerator, providing a certain power at 4.5 K. A first Air Liquide Cold Compression System (CCS) unit was built and delivered to CERN in 2001. Installed at the beginning of 2002, it was commissioned and tested successfully during year 2002. A series of four sets of identical CCS were then tested in 2004. Another set of four cryogenic centrifugal compressors (CCC) has been delivered to Thomas Jefferson National Accelerator Facility (JLAB) for the Spallation Neutron Source (SNS) in 2002. These compressors were tested and commissioned from December 2004 to July 2005. The experimental results obtained with these systems will be presented and discussed: the characteristics of the CCC wil...

  10. Physical Patterns Associated with 27 April 2011 Tornado Outbreak

    Science.gov (United States)

    Ramos, Fernanda; Salem, Thomas

    2012-02-01

    The National Weather Service office in Memphis, Tennessee has aimed their efforts to improve severe tornado forecasting. Everything is not known about tornadogenesis, but one thing is: tornadoes tend to form within supercell thunderstorms. Hence, 27 April 2011 and 25 May 2011 were days when a Tornado Outbreak was expected to arise. Although 22 tornadoes struck the region on 27 April 2011, only 1 impacted the area on 25 May 2011. In order to understand both events, comparisons of their physical features were made. These parameters were studied using the Weather Event Simulator system and the NOAA/NWS Storm Prediction database. This research concentrated on the Surface Frontal Analysis, NAM40 700mb Dew-Points, NAM80 250mb Wind Speed and NAM20 500mb Vorticity images as well as 0-6 km Shear, MUCAPE and VGP mesoscale patterns. As result of this research a Dry-Line ahead of a Cold Front, Dew-points 5C and higher, and high Vorticity values^ were synoptic patterns that influenced to the formation of supercell tornadoes. Finally, MUCAPE and VGP favored the possibility of tornadoes occurrence on 25 May 2011, but shear was the factor that made 27 April 2011 a day for a Tornado Outbreak weather event.

  11. The results of air treatment process modeling at the location of the air curtain in the air suppliers and ventilation shafts

    Directory of Open Access Journals (Sweden)

    Nikolaev Aleksandr

    2017-01-01

    Full Text Available In the existing shaft air heater installations (AHI, that heat the air for air suppliers in cold seasons, a heater channel is used. Some parts of the air from the heater go to the channel, other parts are sucked through a pithead by the general shaft pressure drawdown formed by the main ventilation installation (MVI. When this happens, a mix of two air flows leads to a shaft heat regime violation that can break pressurization of intertubular sealers. The problem of energy saving while airing underground mining enterprises is also very important. The proposed solution of both tasks due to the application of an air curtain is described in the article. In cold seasons the air treatment process should be used and it is offered to place an air curtain in the air suppliers shaft above the place of interface of the calorifer channel to a trunk in order to avoid an infiltration (suction of air through the pithead. It’s recommended to use an air curtain in a ventilation shaft because it reduces external air leaks thereby improving energy efficiency of the MVI work. During the mathematical modeling of ventilation and air preparation process (in SolidWorks Flowsimulation software package it was found out that the use of the air curtain in the air supply shaft can increase the efficiency of the AHI, and reduce the electricity consumption for ventilation in the ventilation shaft.

  12. Interaction of Shallow Cold Surges with Topography on Scales of 100-1000 Kilometers.

    Science.gov (United States)

    Toth, James John

    1987-09-01

    A shallow cold air mass is defined as one not extending to the top of the mountain ridge with which it interacts. The structure of such an airmass is examined using both observational data and a hydrostatic version of the Colorado State University Regional Atmospheric Modeling System. The prime constraint on a shallow cold surge is that the flow must ultimately be parallel to the mountain ridge. It is found that the effects of this constraint are altered significantly by surface sensible heat flux. Cold surges are slowed during the daylight hours, a result consistent with previous observational studies in Colorado east of the Continental Divide. Two case studies are described in detail, and several other events are cited. Since observations alone do not provide a complete description of diversion of the cold air by the mountain range, numerical model simulations provide additional insight into important mechanisms. A case study on 14 June 1985 is described using observational and model data. The model development of a deep boundary layer within the frontal baroclinic zone is consistent with the observations for this and other cases. This development is due to strong surface heating. Turning off the model shortwave radiation is seen to produce a rapid southward acceleration of the surface front, with very shallow cold air behind the front. Model simulations with specified surface temperature differences confirm the importance of upward heat flux from the surface in slowing the southward movement of the cold surge. It is concluded that the slowing is not due simply to the thermal wind developing in response to the heating of higher terrain to the west. Since surface heating is distributed over a deeper layer on the warm side of the temperature discontinuity, there is frontolysis at the surface. But this modification would develop even over flat terrain. Sloping terrain introduces additional effects. Heating at the western, upslope side of the cold surge inhibits the

  13. Yellow Fever outbreak in Darfur, Sudan in October 2012; the initial outbreak investigation report

    Directory of Open Access Journals (Sweden)

    Mohammed A. Soghaier

    2013-10-01

    Full Text Available Summary: Introduction: Sudan is subject to repeated outbreaks, including Viral Hemorrhagic Fever (VHF, which is considered to be a very serious illness. Yellow Fever (YF outbreaks in Sudan have been reported from the 1940s through 2005. In 2012, a new outbreak of YF occurred in the Darfur region. Objective: To identify the potential for an outbreak, to diagnose the disease and to be able to recognize its cause among the initial reported cases. Methodology: >This is a descriptive and investigative field study that applies standard communicable disease outbreak investigation steps. The study involved clinical, serological, entomological and environmental surveys. Results: The field investigation confirmed the outbreak and identified its cause to be YF. Conclusion: National surveillance systems should be strong enough to detect VHFs in a timely manner. Local health facilities should be prepared to promptly treat the initial cases because the case fatality ratios (CFRs are usually very high among the index cases. Keywords: Yellow Fever, Sudan, Darfur, VHFs, Soghaier

  14. Yellow Fever outbreak in Darfur, Sudan in October 2012; the initial outbreak investigation report.

    Science.gov (United States)

    Soghaier, Mohammed A; Hagar, Ahmed; Abbas, Mohammed A; Elmangory, Mutasim M; Eltahir, Khalid M; Sall, Amadou A

    2013-10-01

    Sudan is subject to repeated outbreaks, including Viral Hemorrhagic Fever (VHF), which is considered to be a very serious illness. Yellow Fever (YF) outbreaks in Sudan have been reported from the 1940s through 2005. In 2012, a new outbreak of YF occurred in the Darfur region. To identify the potential for an outbreak, to diagnose the disease and to be able to recognize its cause among the initial reported cases. >This is a descriptive and investigative field study that applies standard communicable disease outbreak investigation steps. The study involved clinical, serological, entomological and environmental surveys. The field investigation confirmed the outbreak and identified its cause to be YF. National surveillance systems should be strong enough to detect VHFs in a timely manner. Local health facilities should be prepared to promptly treat the initial cases because the case fatality ratios (CFRs) are usually very high among the index cases. Copyright © 2013 King Saud Bin Abdulaziz University for Health Sciences. Published by Elsevier Ltd. All rights reserved.

  15. Incentives for reporting disease outbreaks.

    Directory of Open Access Journals (Sweden)

    Ramanan Laxminarayan

    Full Text Available BACKGROUND: Countries face conflicting incentives to report infectious disease outbreaks. Reports of outbreaks can prompt other countries to impose trade and travel restrictions, which has the potential to discourage reporting. However, reports can also bring medical assistance to contain the outbreak, including access to vaccines. METHODS: We compiled data on reports of meningococcal meningitis to the World Health Organization (WHO from 54 African countries between 1966 and 2002, a period is marked by two events: first, a large outbreak reported from many countries in 1987 associated with the Hajj that resulted in more stringent requirements for meningitis vaccination among pilgrims; and second, another large outbreak in Sub-Saharan Africa in 1996 that led to a new international mechanism to supply vaccines to countries reporting a meningitis outbreak. We used fixed-effects regression modeling to statistically estimate the effect of external forcing events on the number of countries reporting cases of meningitis to WHO. FINDINGS: We find that the Hajj vaccination requirements started in 1988 were associated with reduced reporting, especially among countries with relatively fewer cases reported between 1966 and 1979. After the vaccine provision mechanism was in place in 1996, reporting among countries that had previously not reported meningitis outbreaks increased. INTERPRETATION: These results indicate that countries may respond to changing incentives to report outbreaks when they can do so. In the long term, these incentives are likely to be more important than surveillance assistance in prompt reporting of outbreaks.

  16. Energy engineering. Standardization in the domain of coldness production; Genie energetique. Normalisation dans le domaine du froid

    Energy Technology Data Exchange (ETDEWEB)

    Legent, N. [Association Francaise de Normalisation (AFNOR), 92 - Paris-la-Defense (France)

    2000-10-01

    This paper deals with the recent advances in the domain of standardization and regulation of refrigeration and cold production systems used in the industry and in the commercial sector: 1 - international standardization; 2 - European standardization; 3 - international standardization in the domain of cold production (ISO/TC 86 'coldness and air conditioning', CEI 61C 'domestic refrigerating appliances', CEI 61D 'air-conditioning appliances for domestic and similar use', ISO/TC 104 'goods transportation containers'); 4 - European standardization in the domain of cold production (CEN/TC 182 'refrigerating systems - safety and environment requirements', CEN/TC 44 'household refrigerating appliances and refrigerating furniture for stores', CEN/TC 113 'heat pumps and air-conditioners', CEN/TC 141 'manometers and thermometers, measuring and recording means', CENELEC 61 'safety of domestic electrical appliances'); 5 - French standardization (international file, European file, French file, French standardization system); 6 - national standardization in other countries; 7 - regulations in the domain of cold production. (J.S.)

  17. Cold Vacuum Drying facility personnel monitoring system design description

    International Nuclear Information System (INIS)

    PITKOFF, C.C.

    1999-01-01

    This document describes the Cold Vacuum Drying Facility (CVDF) instrument air (IA) system that provides instrument quality air to the CVDF. The IA system provides the instrument quality air used in the process, HVAC, and HVAC instruments. The IA system provides the process skids with air to aid in the purging of the annulus of the transport cask. The IA system provides air for the solenoid-operated valves and damper position controls for isolation, volume, and backdraft in the HVAC system. The IA system provides air for monitoring and control of the HVAC system, process instruments, gas-operated valves, and solenoid-operated instruments. The IA system also delivers air for operating hand tools in each of the process bays

  18. Air dehumidification by membrane with cold water for manned spacecraft environmental control

    Directory of Open Access Journals (Sweden)

    Shang Yonghong

    2017-01-01

    Full Text Available The traditional condensation dehumidification method requires additional gas-liquid separation and water recovery process in the manned spacecraft humidity control system, which would increase weight and complexity of systems. A new membrane dehumidification with cold water is proposed, which uses water vapor partial pressure difference to promote water vapor transmembrane mass transfer for dehumidification. The permeability of the membrane was measured and the experimental results agree well with the theoretical calculations. Based on the simulation of dehumidification process of cold water-membrane, the influence of module structure and working condition on dehumidification performance was analyzed, which provided reference for the design of membrane module construct. It can be seen from the simulation and experiments that the cold water-membrane dehumidification can effectively reduce the thermal load of the manned spacecraft.

  19. Superconducting superferric dipole magnet with cold iron core for the VLHC

    CERN Document Server

    Foster, G W

    2002-01-01

    Magnetic system of the stage I Very Large Hadron Collider (VLHC) is based on 2 Tesla superconducting magnets with combined functions. These magnets have a room temperature iron yoke with two 20 mm air gaps. Magnetic field in both horizontally separated air gaps is generated by a single, 100 kA superconducting transmission line. An alternative design with a cold iron yoke, horizontally or vertically separated air gaps is under investigation. The cold iron option with horizontally separated air gaps reduces the amount of iron, which is one of the major cost drivers for the 233-km magnet system of future accelerator. The vertical beam separation decreases the superconductor volume, heat load from the synchrotron radiation and eliminates fringe field from the return bus. Nevertheless, the horizontal beam separation provides lowest volume of the iron yoke and, therefore, smaller heat load on the cryogenic system during cooling down. All these options are discussed and compared in the paper. Superconducting correct...

  20. Selection tool for foodborne norovirus outbreaks.

    Science.gov (United States)

    Verhoef, Linda P B; Kroneman, Annelies; van Duynhoven, Yvonne; Boshuizen, Hendriek; van Pelt, Wilfrid; Koopmans, Marion

    2009-01-01

    Detection of pathogens in the food chain is limited mainly to bacteria, and the globalization of the food industry enables international viral foodborne outbreaks to occur. Outbreaks from 2002 through 2006 recorded in a European norovirus surveillance database were investigated for virologic and epidemiologic indicators of food relatedness. The resulting validated multivariate logistic regression model comparing foodborne (n = 224) and person-to-person (n = 654) outbreaks was used to create a practical web-based tool that can be limited to epidemiologic parameters for nongenotyping countries. Non-genogroup-II.4 outbreaks, higher numbers of cases, and outbreaks in restaurants or households characterized (sensitivity = 0.80, specificity = 0.86) foodborne outbreaks and reduced the percentage of outbreaks requiring source-tracing to 31%. The selection tool enabled prospectively focused follow-up. Use of this tool is likely to improve data quality and strain typing in current surveillance systems, which is necessary for identification of potential international foodborne outbreaks.

  1. Variability in cold front activities modulating cool-season evaporation from a southern inland water in the USA

    International Nuclear Information System (INIS)

    Liu Heping; Blanken, Peter D; Weidinger, Tamas; Nordbo, Annika; Vesala, Timo

    2011-01-01

    Understanding seasonal variations in the evaporation of inland waters (e.g., lakes and reservoirs) is important for water resource management as well as the prediction of the hydrological cycles in response to climate change. We analyzed eddy covariance-based evaporation measurements from the Ross Barnett Reservoir (32 deg. 26'N, 90 0 02'W; which is always ice-free) in central Mississippi during the cool months (i.e., September-March) of 2007 and 2008, and found that the variability in cold front activities (i.e., passages of cold fronts and cold/dry air masses behind cold fronts) played an important role in modulating the exchange of sensible (H) and latent (λE) heat fluxes. Our analysis showed that 2007's warmer cool season had smaller mean H and λE than 2008's cooler cool season. This implies that the warmer cool season did not accelerate evaporation and heat exchange between the water surface and the atmosphere. Instead, more frequent cold fronts and longer periods of cold/dry air masses behind the cold fronts in 2008 resulted in overall larger H and λE as compared with 2007, this primarily taking the form of sporadic short-term rapid 'pulses' of H and λE losses from the water's surface. These results suggest that future climate-induced changes in frequency of cold fronts and the meteorological properties of the air masses behind cold fronts (e.g., wind speeds, temperature, and humidity), rather than other factors of climate change, would produce significant variations in the water surface's energy fluxes and subsequent evaporation rates.

  2. Outbreak Column 16: Cognitive errors in outbreak decision making.

    Science.gov (United States)

    Curran, Evonne T

    2015-01-01

    During outbreaks, decisions must be made without all the required information. People, including infection prevention and control teams (IPCTs), who have to make decisions during uncertainty use heuristics to fill the missing data gaps. Heuristics are mental model short cuts that by-and-large enable us to make good decisions quickly. However, these heuristics contain biases and effects that at times lead to cognitive (thinking) errors. These cognitive errors are not made to deliberately misrepresent any given situation; we are subject to heuristic biases when we are trying to perform optimally. The science of decision making is large; there are over 100 different biases recognised and described. Outbreak Column 16 discusses and relates these heuristics and biases to decision making during outbreak prevention, preparedness and management. Insights as to how we might recognise and avoid them are offered.

  3. The design and commissioning of cold trap purifying system of hydrogen meter sodium loop

    International Nuclear Information System (INIS)

    Zhao Zhaoyi; Jia Baoshan; Chen Xiaoming; Pan Fengguo

    1993-01-01

    The design feature and parameters of cold trap purifying system of hydrogen meter sodium loop and its commissioning results are reported and discussed. In order to adjust the flow easily,. the cold trap purifying system is arranged in the exit of the electromagnetic pump. It is composed of regenerator and the cold trap. The regenerator is above the cold trap. The high temperature sodium in the main-loop flows through the regenerator, in the entrance of the cold trap, its temperature is reduced to 180 degree C. After entering into the cold trap, the sodium flows to the purifying region by side, when it arrives the bottom of the trap, its temperature is reduced to 110 degree C. The cold trap is cooled by air. The temperature of the clean sodium rises nearby the main-loop's by the regenerator, and then it returns to the entrance of the electromagnetic pump. According to the commissioning results, the sodium's temperature of the cold trap could be reduced to 110 degree C by reducing the flow of the cold trap purifying system and the temperature of the main-loop, or increasing the air flow and cutting off the power supply of its heating. The authors think that the latter is more conformable with the design stipulation and with the requirement of the hydrogen meter experiment, and it can meet the requirements of the operation of the Nuclear Power Plant

  4. Thermotechnical comparison of possible operation variants for air conditioning system of mine air with high pressure heat exchanger and hydrodistributor

    OpenAIRE

    Korsun, F. O.

    2015-01-01

    Problem. There are vast losses of cold that take place during the transition of cold to deep horizons of shafts by the mine air conditioning system (MASC) with high pressure heat exchanger. Cold is transferred by the recuperative way. Vast losses of cold mean vast losses of electricity to in order to supply it. Any enterprise requires the reduction of electricity consumption. This article gives proposals on how to replace HPHE into hydrodistributor which will considerably reduce cold losses. ...

  5. Numerical responses of saproxylic beetles to rapid increases in dead wood availability following geometrid moth outbreaks in sub-arctic mountain birch forest.

    Science.gov (United States)

    Vindstad, Ole Petter Laksforsmo; Schultze, Sabrina; Jepsen, Jane Uhd; Biuw, Martin; Kapari, Lauri; Sverdrup-Thygeson, Anne; Ims, Rolf Anker

    2014-01-01

    Saproxylic insects play an important part in decomposing dead wood in healthy forest ecosystems, but little is known about their role in the aftermath of large-scale forest mortality caused by pest insect outbreaks. We used window traps to study short-term changes in the abundance and community structure of saproxylic beetles following extensive mortality of mountain birch in sub-arctic northern Norway caused by an outbreak of geometrid moths. Three to five years after the outbreak, the proportion of obligate saproxylic individuals in the beetle community was roughly 10% higher in forest damaged by the outbreak than in undamaged forest. This was mainly due to two early-successional saproxylic beetle species. Facultative saproxylic beetles showed no consistent differences between damaged and undamaged forest. These findings would suggest a weak numerical response of the saproxylic beetle community to the dead wood left by the outbreak. We suggest that species-specific preferences for certain wood decay stages may limit the number of saproxylic species that respond numerically to an outbreak at a particular time, and that increases in responding species may be constrained by limitations to the amount of dead wood that can be exploited within a given timeframe (i.e. satiation effects). Low diversity of beetle species or slow development of larvae in our cold sub-arctic study region may also limit numerical responses. Our study suggests that saproxylic beetles, owing to weak numerical responses, may so far have played a minor role in decomposing the vast quantities of dead wood left by the moth outbreak.

  6. Numerical responses of saproxylic beetles to rapid increases in dead wood availability following geometrid moth outbreaks in sub-arctic mountain birch forest.

    Directory of Open Access Journals (Sweden)

    Ole Petter Laksforsmo Vindstad

    Full Text Available Saproxylic insects play an important part in decomposing dead wood in healthy forest ecosystems, but little is known about their role in the aftermath of large-scale forest mortality caused by pest insect outbreaks. We used window traps to study short-term changes in the abundance and community structure of saproxylic beetles following extensive mortality of mountain birch in sub-arctic northern Norway caused by an outbreak of geometrid moths. Three to five years after the outbreak, the proportion of obligate saproxylic individuals in the beetle community was roughly 10% higher in forest damaged by the outbreak than in undamaged forest. This was mainly due to two early-successional saproxylic beetle species. Facultative saproxylic beetles showed no consistent differences between damaged and undamaged forest. These findings would suggest a weak numerical response of the saproxylic beetle community to the dead wood left by the outbreak. We suggest that species-specific preferences for certain wood decay stages may limit the number of saproxylic species that respond numerically to an outbreak at a particular time, and that increases in responding species may be constrained by limitations to the amount of dead wood that can be exploited within a given timeframe (i.e. satiation effects. Low diversity of beetle species or slow development of larvae in our cold sub-arctic study region may also limit numerical responses. Our study suggests that saproxylic beetles, owing to weak numerical responses, may so far have played a minor role in decomposing the vast quantities of dead wood left by the moth outbreak.

  7. Excess cardiovascular mortality associated with cold spells in the Czech Republic

    Directory of Open Access Journals (Sweden)

    Kyncl Jan

    2009-01-01

    Full Text Available Abstract Background The association between cardiovascular mortality and winter cold spells was evaluated in the population of the Czech Republic over 21-yr period 1986–2006. No comprehensive study on cold-related mortality in central Europe has been carried out despite the fact that cold air invasions are more frequent and severe in this region than in western and southern Europe. Methods Cold spells were defined as periods of days on which air temperature does not exceed -3.5°C. Days on which mortality was affected by epidemics of influenza/acute respiratory infections were identified and omitted from the analysis. Excess cardiovascular mortality was determined after the long-term changes and the seasonal cycle in mortality had been removed. Excess mortality during and after cold spells was examined in individual age groups and genders. Results Cold spells were associated with positive mean excess cardiovascular mortality in all age groups (25–59, 60–69, 70–79 and 80+ years and in both men and women. The relative mortality effects were most pronounced and most direct in middle-aged men (25–59 years, which contrasts with majority of studies on cold-related mortality in other regions. The estimated excess mortality during the severe cold spells in January 1987 (+274 cardiovascular deaths is comparable to that attributed to the most severe heat wave in this region in 1994. Conclusion The results show that cold stress has a considerable impact on mortality in central Europe, representing a public health threat of an importance similar to heat waves. The elevated mortality risks in men aged 25–59 years may be related to occupational exposure of large numbers of men working outdoors in winter. Early warnings and preventive measures based on weather forecast and targeted on the susceptible parts of the population may help mitigate the effects of cold spells and save lives.

  8. The cold neutron source in DR 3

    International Nuclear Information System (INIS)

    Jensen, K.; Leth, j.A.

    1980-09-01

    A description of the cold neutron source in DR 3 is given. The moderator of the cold neutron source is supercritical hydrogen at about 30degK and 15 bar abs. The necessary cooling capacity is supplied by two Philips Stirling B20 cryogenerators. The hydrogen is circulated between the cryogenerators and the in-pile moderator chamber by small fans. The safety of the facility is based on the use of triple containment preventing contact between hydrogen and air. The triple containment is achieved by enclosing the high vacuum system, surrounging the hydrogen system, in a helium blanket. The achieved spectrum of the thermal neutron flux and the gain factor are given as well as the experience from more than 5 years of operation. Finally some work on extension of the facility to operate two cold sources is reported. (author)

  9. Experimental Results Obtained with Air Liquide Cold Compression System: CERN LHC and SNS Projects

    Science.gov (United States)

    Delcayre, F.; Courty, J.-C.; Hamber, F.; Hilbert, B.; Monneret, E.; Toia, J.-L.

    2006-04-01

    Large scale collider facilities will make intensive use of superconducting magnets, operating below 2.0 K. This dictates high-capacity refrigeration systems operating below 2.0 K. These systems, making use of cryogenic centrifugal compressors in a series arrangement with room temperature screw compressors will be coupled to a refrigerator, providing a certain power at 4.5 K. A first Air Liquide Cold Compression System (CCS) unit was built and delivered to CERN in 2001. Installed at the beginning of 2002, it was commissioned and tested successfully during year 2002. A series of four sets of identical CCS were then tested in 2004. Another set of four cryogenic centrifugal compressors (CCC) has been delivered to Thomas Jefferson National Accelerator Facility (JLAB) for the Spallation Neutron Source (SNS) in 2002. These compressors were tested and commissioned from December 2004 to July 2005. The experimental results obtained with these systems will be presented and discussed: the characteristics of the CCC will be detailed. The principles of control for the CCC in series will be detailed.

  10. Assessment of cold-climate environmental research priorities. Appendixes A, B

    Energy Technology Data Exchange (ETDEWEB)

    States, J.B.

    1983-04-01

    These appendices present research plans in the areas of air pollution, water contamination/consumption, habitat modification and waste management that are relevant to the EPA's cold regions program. (ACR)

  11. Forecasting rodent outbreaks in Africa

    DEFF Research Database (Denmark)

    Leirs, Herwig; Verhagen, Ron; Verheyen, Walter

    1996-01-01

    1. Rainfall data were collated for years preceding historical outbreaks of Mastomys rats in East Africa in order to test the hypothesis that such outbreaks occur after long dry periods. 2. Rodent outbreaks were generally not preceded by long dry periods. 3. Population dynamics of Mastomys...... natalensis rats in Tanzania are significantly affected by the distribution of rainfall during the rainy season. 4. All previous rodent outbreaks in Tanzania were preceded by abundant rainfall early in the rainy season, i.e, towards the end of the year. 5. A flow chart is constructed to assess the likelihood...

  12. Cold pool organization and the merging of convective updrafts in a Large Eddy Simulation

    Science.gov (United States)

    Glenn, I. B.; Krueger, S. K.

    2016-12-01

    Cold pool organization is a process that accelerates the transition from shallow to deep cumulus convection, and leads to higher deep convective cloud top heights. The mechanism by which cold pool organization enhances convection remains not well understood, but the basic idea is that since precipitation evaporation and a low equivalent potential temperature in the mid-troposphere lead to strong cold pools, the net cold pool effect can be accounted for in a cumulus parameterization as a relationship involving those factors. Understanding the actual physical mechanism at work will help quantify the strength of the relationship between cold pools and enhanced deep convection. One proposed mechanism of enhancement is that cold pool organization leads to reduced distances between updrafts, creating a local environment more conducive to convection as updrafts entrain parcels of air recently detrained by their neighbors. We take this hypothesis one step further and propose that convective updrafts actually merge, not just exchange recently processed air. Because entrainment and detrainment around an updraft draws nearby air in or pushes it out, respectively, they act like dynamic flow sources and sinks, drawing each other in or pushing each other away. The acceleration is proportional to the inverse square of the distance between two updrafts, so a small reduction in distance can make a big difference in the rate of merging. We have shown in previous research how merging can be seen as collisions between different updraft air parcels using Lagrangian Parcel Trajectories (LPTs) released in a Large Eddy Simulation (LES) during a period with organized deep convection. Now we use a Eulerian frame of reference to examine the updraft merging process during the transition from shallow to organized deep convection. We use a case based on the Large-Scale Biosphere-Atmosphere Experiment in Amazonia (LBA) for our LES. We directly measure the rate of entrainment and the properties

  13. Detection of cold pain, cold allodynia and cold hyperalgesia in freely behaving rats

    Directory of Open Access Journals (Sweden)

    Woolf Clifford J

    2005-12-01

    Full Text Available Abstract Background Pain is elicited by cold, and a major feature of many neuropathic pain states is that normally innocuous cool stimuli begin to produce pain (cold allodynia. To expand our understanding of cold induced pain states we have studied cold pain behaviors over a range of temperatures in several animal models of chronic pain. Results We demonstrate that a Peltier-cooled cold plate with ± 1°C sensitivity enables quantitative measurement of a detection withdrawal response to cold stimuli in unrestrained rats. In naïve rats the threshold for eliciting cold pain behavior is 5°C. The withdrawal threshold for cold allodynia is 15°C in both the spared nerve injury and spinal nerve ligation models of neuropathic pain. Cold hyperalgesia is present in the spared nerve injury model animals, manifesting as a reduced latency of withdrawal response threshold at temperatures that elicit cold pain in naïve rats. We also show that following the peripheral inflammation produced by intraplantar injection of complete Freund's adjuvant, a hypersensitivity to cold occurs. Conclusion The peltier-cooled provides an effective means of assaying cold sensitivity in unrestrained rats. Behavioral testing of cold allodynia, hyperalgesia and pain will greatly facilitate the study of the neurobiological mechanisms involved in cold/cool sensations and enable measurement of the efficacy of pharmacological treatments to reduce these symptoms.

  14. TOWARDS MODELING DISEASE OUTBREAK NOTIFICATION SYSTEMS

    OpenAIRE

    Farag Azzedin; Jaweed Yazdani,; Salahadin Adam; Mustafa Ghaleb

    2014-01-01

    Disease outbreak detection, monitoring and notification systems play an important role in assessing threats to public health since disease outbreaks are becoming increasingly common world-wide. There are several systems in use around the world, with coverage of national, international and global disease outbreaks. These systems use different taxonomies and classifications for the detection and prioritization of potential disease outbreaks. In this paper, we study and analyze th...

  15. A Hospital-wide Outbreak of Serratia marcescens, and Ishikawa's “Fishbone” Analysis to Support Outbreak Control

    Science.gov (United States)

    Vetter, Luzia; Schuepfer, Guido; Kuster, Stefan P.

    2016-01-01

    A nosocomial outbreak of Serratia marcescens in respiratory samples predominantly from patients in a surgical intensive care unit is reported. Most of these patients were cardiac surgical patients. Initially, a vigorous but inconclusive investigation was implemented on the basis of standardized (according the US Centers for Disease Control and Prevention) steps of outbreak investigation. Then, a systemic quality management approach with “fishbone” analysis was added. As a consequence, plausible causes for the outbreak were identified: (i) S marcescens was found on the transesophageal echocardiography probe used during cardiac surgery; and (ii) the quality of the surface disinfection was insufficient due to multiple reasons and was completely reengineered. In conclusion, in addition to the standardized steps of outbreak investigation, the complementary use of quality management tools such as the Ishikawa “fishbone” analysis is helpful for outbreak control. The complete reengineering of the disinfectant procurement and logistics is assumed to have been the most effective measure to control the described outbreak. PMID:26783861

  16. International foodborne outbreak of Shigella sonnei infection in airline passengers.

    Science.gov (United States)

    Gaynor, K; Park, S Y; Kanenaka, R; Colindres, R; Mintz, E; Ram, P K; Kitsutani, P; Nakata, M; Wedel, S; Boxrud, D; Jennings, D; Yoshida, H; Tosaka, N; He, H; Ching-Lee, M; Effler, P V

    2009-03-01

    During 22-24 August 2004, an outbreak of Shigella sonnei infection affected air travellers who departed from Hawaii. Forty-seven passengers with culture-confirmed shigellosis and 116 probable cases who travelled on 12 flights dispersed to Japan, Australia, 22 US states, and American Samoa. All flights were served by one caterer. Pulsed-field gel electrophoresis of all 29 S. sonnei isolates yielded patterns that matched within one band. Food histories and menu reviews identified raw carrot served onboard as the likely vehicle of infection. Attack rates for diarrhoea on three surveyed flights with confirmed cases were 54% (110/204), 32% (20/63), and 12% (8/67). A total of 2700 meals were served on flights with confirmed cases; using attack rates observed on surveyed flights, we estimated that 300-1500 passengers were infected. This outbreak illustrates the risk of rapid, global spread of illness from a point-source at a major airline hub.

  17. Dengue disease outbreak definitions are implicitly variable

    Directory of Open Access Journals (Sweden)

    Oliver J. Brady

    2015-06-01

    Full Text Available Infectious diseases rarely exhibit simple dynamics. Outbreaks (defined as excess cases beyond response capabilities have the potential to cause a disproportionately high burden due to overwhelming health care systems. The recommendations of international policy guidelines and research agendas are based on a perceived standardised definition of an outbreak characterised by a prolonged, high-caseload, extra-seasonal surge. In this analysis we apply multiple candidate outbreak definitions to reported dengue case data from Brazil to test this assumption. The methods identify highly heterogeneous outbreak characteristics in terms of frequency, duration and case burden. All definitions identify outbreaks with characteristics that vary over time and space. Further, definitions differ in their timeliness of outbreak onset, and thus may be more or less suitable for early intervention. This raises concerns about the application of current outbreak guidelines for early warning/identification systems. It is clear that quantitatively defining the characteristics of an outbreak is an essential prerequisite for effective reactive response. More work is needed so that definitions of disease outbreaks can take into account the baseline capacities of treatment, surveillance and control. This is essential if outbreak guidelines are to be effective and generalisable across a range of epidemiologically different settings.

  18. A Survey of Precipitation-Induced Atmospheric Cold Pools over Oceans and Their Interactions with the Larger-Scale Environment

    Science.gov (United States)

    Zuidema, Paquita; Torri, Giuseppe; Muller, Caroline; Chandra, Arunchandra

    2017-11-01

    Pools of air cooled by partial rain evaporation span up to several hundreds of kilometers in nature and typically last less than 1 day, ultimately losing their identity to the large-scale flow. These fundamentally differ in character from the radiatively-driven dry pools defining convective aggregation. Advancement in remote sensing and in computer capabilities has promoted exploration of how precipitation-induced cold pool processes modify the convective spectrum and life cycle. This contribution surveys current understanding of such cold pools over the tropical and subtropical oceans. In shallow convection with low rain rates, the cold pools moisten, preserving the near-surface equivalent potential temperature or increasing it if the surface moisture fluxes cannot ventilate beyond the new surface layer; both conditions indicate downdraft origin air from within the boundary layer. When rain rates exceed ˜ 2 mm h^{-1}, convective-scale downdrafts can bring down drier air of lower equivalent potential temperature from above the boundary layer. The resulting density currents facilitate the lifting of locally thermodynamically favorable air and can impose an arc-shaped mesoscale cloud organization. This organization allows clouds capable of reaching 4-5 km within otherwise dry environments. These are more commonly observed in the northern hemisphere trade wind regime, where the flow to the intertropical convergence zone is unimpeded by the equator. Their near-surface air properties share much with those shown from cold pools sampled in the equatorial Indian Ocean. Cold pools are most effective at influencing the mesoscale organization when the atmosphere is moist in the lower free troposphere and dry above, suggesting an optimal range of water vapor paths. Outstanding questions on the relationship between cold pools, their accompanying moisture distribution and cloud cover are detailed further. Near-surface water vapor rings are documented in one model inside but

  19. Salmonellosis outbreak due to chicken contact leading to a foodborne outbreak associated with infected delicatessen workers.

    Science.gov (United States)

    Hedican, Erin; Miller, Ben; Ziemer, Brian; LeMaster, Pam; Jawahir, Selina; Leano, Fe; Smith, Kirk

    2010-08-01

    Salmonella is the most common bacterial cause of foodborne outbreaks in the United States. Starting in June 2007, investigation of a cluster of Salmonella Montevideo cases with indistinguishable pulsed-field gel electrophoresis (PFGE) patterns resulted in the identification of an outbreak associated with contact with chickens purchased from a single hatchery. Nine Minnesota cases from May through August 2007 were part of this outbreak. Cases with the outbreak PFGE pattern of Salmonella Montevideo continued to occur in Minnesota after August, but none of these cases reported chicken contact. The majority of these cases resided in the same town in rural Minnesota. Routine interviews revealed that all cases from these counties purchased groceries from the same local grocery store, with two specifically reporting consuming items from the grocery store delicatessen in the week before illness. As a result, an investigation into the delicatessen was initiated. Illness histories and stool samples were collected from all delicatessen employees, and food and environmental samples were collected. None of the employees reported experiencing recent gastrointestinal symptoms, but the outbreak PFGE subtype of Salmonella Montevideo was identified from stool from two food workers. Food and environmental samples collected tested negative for Salmonella. One of the positive employees reported having chickens at home, but the animals did not test positive for Salmonella. The positive food workers were excluded from work until they had two consecutive negative stool cultures for Salmonella. There was no evidence of ongoing transmission thereafter. This was an outbreak of Salmonella Montevideo infections that began as an animal-contact-associated outbreak which subsequently resulted in a foodborne outbreak associated with infected food workers. These outbreaks illustrate the complex epidemiology of salmonellosis.

  20. Application of Artificial Neural Networks for Dengue Fever Outbreak Predictions in the Northwest Coast of Yucatan, Mexico and San Juan, Puerto Rico

    Directory of Open Access Journals (Sweden)

    Abdiel E. Laureano-Rosario

    2018-01-01

    Full Text Available Modelling dengue fever in endemic areas is important to mitigate and improve vector-borne disease control to reduce outbreaks. This study applied artificial neural networks (ANNs to predict dengue fever outbreak occurrences in San Juan, Puerto Rico (USA, and in several coastal municipalities of the state of Yucatan, Mexico, based on specific thresholds. The models were trained with 19 years of dengue fever data for Puerto Rico and six years for Mexico. Environmental and demographic data included in the predictive models were sea surface temperature (SST, precipitation, air temperature (i.e., minimum, maximum, and average, humidity, previous dengue cases, and population size. Two models were applied for each study area. One predicted dengue incidence rates based on population at risk (i.e., numbers of people younger than 24 years, and the other on the size of the vulnerable population (i.e., number of people younger than five years and older than 65 years. The predictive power was above 70% for all four model runs. The ANNs were able to successfully model dengue fever outbreak occurrences in both study areas. The variables with the most influence on predicting dengue fever outbreak occurrences for San Juan, Puerto Rico, included population size, previous dengue cases, maximum air temperature, and date. In Yucatan, Mexico, the most important variables were population size, previous dengue cases, minimum air temperature, and date. These models have predictive skills and should help dengue fever mitigation and management to aid specific population segments in the Caribbean region and around the Gulf of Mexico.

  1. Two nursing home outbreaks of respiratory infection with Legionella sainthelensi.

    Science.gov (United States)

    Loeb, M; Simor, A E; Mandell, L; Krueger, P; McArthur, M; James, M; Walter, S; Richardson, E; Lingley, M; Stout, J; Stronach, D; McGeer, A

    1999-05-01

    To describe outbreaks of infection caused by Legionella sainthelensi occurring in older residents of two nursing homes and to determine risk factors for the development of infection. Descriptive epidemiology and a case-control study. Two nursing homes (140 beds and 254 beds in nursing homes A and B, respectively) located in southern Ontario, Canada, experiencing outbreaks of respiratory tract infection in July and August 1994. Case-residents of the two nursing homes who met clinical and laboratory criteria for Legionella infection. Control-residents were defined as those who were in the homes during the outbreaks and were asymptomatic. Active surveillance was conducted in both nursing homes to identify symptomatic residents. Residents with fever or respiratory tract symptoms had nasopharyngeal swabs taken for viral antigen detection and culture, urine for Legionella antigen detection, and acute and convalescent serology for viruses, Mycoplasma pneumoniae, Chlamydia pneumoniae, and Legionella. Chest X-rays were performed, and an attempt was made to obtain blood and sputum cultures. Water samples from shower heads, faucets, and air conditioning units were collected for Legionella culture and polymerase chain reaction (PCR) assay. A case-control study was done to assess possible risk factors for legionellosis. Twenty-nine cases -- 17 in nursing home A; 12 in nursing home B - were identified. Four (14%) case-residents had documented pneumonia and four case-residents died. Univariate analysis revealed that a history of stroke (odds ratio (OR) 2.3 (95% CI, 1.0-5.3)), eating pureed food (OR 4.6 (95% CI, 1.6-12.7)), and having fluids administered with medication (OR 2.5 (95% CI, 1.0-5.9)) were significant risk factors. Cases were less likely to wear dentures (OR .4 (95% CI, .2-.9)) or to eat solid food (OR .3, (95% CI, .1-.6)). Only eating pureed food remained significant in a multivariable analysis (OR 4.6 (95% CI, 1.6-13.0, P = .01)). This report describes outbreaks of

  2. Investigation of a cholera outbreak in a tea garden of Sivasagar district of Assam

    Directory of Open Access Journals (Sweden)

    Bhupendra Narayan Mahanta

    2013-01-01

    Full Text Available Background: In late May 2012, Bagjan division of Borbam tea estate, of Sivasagar district of Assam was affected by an outbreak of acute watery diarrhea, subsequently confirmed as Vibrio cholerae O1. Objectives: Our objective is to investigate and control the acute diarrheal disease outbreak in Sivasagar district of Assam. Materials and Methods: A physician-epidemiologist-led team did rapid outbreak investigation to confirm the outbreak and instituted treatment and control measures. Quantitative data collection was done using standard schedule and qualitative data by using key informant interview schedule. Results: Spot mapping of cases was done along the garden residential lines. About 120 suspected cases were line listed; with 1:1.23 male: female ratio. Ages ranged from 3 to 70 years (median - 40.5 years. Attack rate was 4.79% with one death; case fatality rate was 0.83%. Open air defecation was practiced by 94.6%. Rectal swabs were positive for V. cholerae O1 (Ogawa. All the piped water samples were class IV unsatisfactory for domestic use. Conclusions: There is a need to improve water and sanitation facility in the tea garden lines along with implementation of a strengthened disease surveillance system through integrated disease surveillance project covering all tea estates.

  3. Detecting and Responding to a Dengue Outbreak: Evaluation of Existing Strategies in Country Outbreak Response Planning

    Directory of Open Access Journals (Sweden)

    Julia Harrington

    2013-01-01

    Full Text Available Background. Dengue outbreaks are occurring with increasing frequency and intensity. Evidence-based epidemic preparedness and effective response are now a matter of urgency. Therefore, we have analysed national and municipal dengue outbreak response plans. Methods. Thirteen country plans from Asia, Latin America and Australia, and one international plan were obtained from the World Health Organization. The information was transferred to a data analysis matrix where information was extracted according to predefined and emerging themes and analysed for scope, inconsistencies, omissions, and usefulness. Findings. Outbreak response planning currently has a considerable number of flaws. Outbreak governance was weak with a lack of clarity of stakeholder roles. Late timing of responses due to poor surveillance, a lack of combining routine data with additional alerts, and lack of triggers for initiating the response weakened the functionality of plans. Frequently an outbreak was not defined, and early response mechanisms based on alert signals were neglected. There was a distinct lack of consideration of contextual influences which can affect how an outbreak detection and response is managed. Conclusion. A model contingency plan for dengue outbreak prediction, detection, and response may help national disease control authorities to develop their own more detailed and functional context specific plans.

  4. Air temperature optimisation for humidity-controlled cold storage of the predatory mites Neoseiulus californicus and Phytoseiulus persimilis (Acari: Phytoseiidae).

    Science.gov (United States)

    Ghazy, Noureldin Abuelfadl; Suzuki, Takeshi; Amano, Hiroshi; Ohyama, Katsumi

    2014-03-01

    Humidity-controlled cold storage, in which the water vapour pressure is saturated, can prolong the survival of the predatory mites Neoseiulus californicus (McGregor) and Phytoseiulus persimilis Athias-Henriot (Acari: Phytoseiidae). However, information on the optimum air temperature for long-term storage by this method is limited. The authors evaluated the survival of mated adult females of N. californicus and P. persimilis at 5.0, 7.5, 10.0 and 12.5 °C under saturated water vapour condition (vapour pressure deficit 0.0 kPa). N. californicus showed a longer survival time than P. persimilis at all the air temperatures. The longest mean survival time of N. californicus was 11 weeks at 7.5 °C, whereas that of P. persimilis was 8 weeks at 5.0 °C. After storage at 7.5 °C for 8 weeks, no negative effect on post-storage oviposition was observed in N. californicus, whereas the oviposition of P. persimilis stored at 5.0 °C for 8 weeks was significantly reduced. The interspecific variation in the response of these predators to low air temperature might be attributed to their natural habitat and energy requirements. These results may be useful for the long-term storage of these predators, which is required for cost-effective biological control. © 2013 Society of Chemical Industry.

  5. Variations of caesium isotope concentrations in air and fallout at Dalat, South Vietnam, 1986-1991

    International Nuclear Information System (INIS)

    Pham Zuy Hien; Nguyen Thanh Binh; Truong Y.; Vuong Thu Bac; Nguyen Trong Ngo.

    1993-01-01

    Monthly records of Cs-137 and Cs-134 concentrations in air and fallout at Dalat for the period 1986-1991 are presented and discussed. The concentration variations exhibit distinct maxima during December-January, when dry fallout dominated. These peaks are explained by the intrusion of more radioactive cold air masses from temperate northern latitudes during the development of large-scale anticyclones frequently observed in the most active winter monsoon period. High dry fallout velocities (about 10 cm/s) determined from this data clearly demonstrate one of the most relevant characteristics of cold air masses: behind the cold front, vertical air motion is descending

  6. Prevention and Management of Cold-Weather Injuries

    Science.gov (United States)

    2005-04-01

    49 d. After an initial stimulation of respiration with mild hypothermia (leading to respiratory alkalosis ), there is a progressive decrease...nonevaporated sweat will reduce clothing insulation and possibly form ice crystals. Breathing cold air can slightly exacerbate respiratory water loss... Respiratory . (1) Upper airway temperatures, which normally remain unchanged during exercise under temperate conditions, can decrease substantially

  7. Evaluation of seasonal exergy efficiency of air handing unit

    Directory of Open Access Journals (Sweden)

    Kęstutis Genys

    2015-10-01

    Full Text Available The article deals with the air handling unit seasonal exergy efficiency. TRNSYS simulation tool is used to evaluate it. The object of research is air treatment device used to treat an air for the ventilation of laboratory. The mathematical model of air handling unit using TRNSYS simulation tool was developed when the technical parameters of air handling unit and energy exchange in it were analysed. The developed model according to the made observations during the warm and cold periods was tested and validation of elements was performed. The simulation of air handling unit operation after the verification of reliability and permitted tolerances was performed. The control mechanisim which allows simulating the operation of air handling unit during cold and warm periods of the year was made. The mathematical algorithm for calculation of air handling unit exergy efficiency coefficient applying the principles of exergy analysis was developed. The seasonal exergy efficiency of air handling unit equal to 3.94 percent during the simulation was obtained.

  8. Pre-outbreak forest conditions mediate the effects of spruce beetle outbreaks on fuels in subalpine forests of Colorado.

    Science.gov (United States)

    Mietkiewicz, Nathan; Kulakowski, Dominik; Veblen, Thomas T

    2018-03-01

    Over the past 30 years, forest disturbances have increased in size, intensity, and frequency globally, and are predicted to continue increasing due to climate change, potentially relaxing the constraints of vegetation properties on disturbance regimes. However, the consequences of the potentially declining importance of vegetation in determining future disturbance regimes are not well understood. Historically, bark beetles preferentially attack older trees and stands in later stages of development. However, as climate warming intensifies outbreaks by promoting growth of beetle populations and compromising tree defenses, smaller diameter trees and stands in early stages of development now are being affected by outbreaks. To date, no study has considered how stand age and other pre-outbreak forest conditions mediate the effects of outbreaks on surface and aerial fuel arrangements. We collected fuels data across a chronosequence of post-outbreak sites affected by spruce beetle (SB) between the 1940s and the 2010s, stratified by young (130 yr) post-fire stands. Canopy and surface fuel loads were calculated for each tree and stand, and available crown fuel load, crown bulk density, and canopy bulk densities were estimated. Canopy bulk density and density of live canopy individuals were reduced in all stands affected by SB, though foliage loss was proportionally greater in old stands as compared to young stands. Fine surface fuel loads in young stands were three times greater shortly (fuels decreased to below endemic (i.e., non-outbreak) levels. In both young and old stands, the net effect of SB outbreaks during the 20th and 21st centuries reduced total canopy fuels and increased stand-scale spatial heterogeneity of canopy fuels following outbreak. Importantly, the decrease in canopy fuels following outbreaks was greater in young post-fire stands than in older stands, suggesting that SB outbreaks may more substantially reduce risk of active crown fire when they affect

  9. Radial Pressure Pulse and Heart Rate Variability in Heat- and Cold-Stressed Humans

    Directory of Open Access Journals (Sweden)

    Chin-Ming Huang

    2011-01-01

    Full Text Available This study aims to explore the effects of heat and cold stress on the radial pressure pulse (RPP and heart rate variability (HRV. The subjects immersed their left hand into 45°C and 7°C water for 2 minutes. Sixty healthy subjects (age 25±4 yr; 29 men and 31 women were enrolled in this study. All subjects underwent the supine temperature measurements of the bilateral forearms, brachial arterial blood pressure, HRV and RPP with a pulse analyzer in normothermic conditions, and thermal stresses. The power spectral low-frequency (LF and high-frequency (HF components of HRV decreased in the heat test and increased in the cold test. The heat stress significantly reduced radial augmentation index (AIr (P<.05, but the cold stress significantly increased AIr (P<.01. The spectral energy of RPP did not show any statistical difference in 0∼10 Hz region under both conditions, but in the region of 10∼50 Hz, there was a significant increase (P<.01 in the heat test and a significant decrease in the cold test (P<.01. The changes in AIr induced by heat and cold stress were significantly negatively correlated with the spectral energy in the region of 10∼50 Hz (SE10−50 Hz but not in the region of 0∼10 Hz (SE0−10 Hz. The results demonstrated that the SE10−50 Hz, which only possessed a small percentage in total pulse energy, presented more physiological characteristics than the SE0−10 Hz under the thermal stresses.

  10. Radial Pressure Pulse and Heart Rate Variability in Heat- and Cold-Stressed Humans

    Science.gov (United States)

    Huang, Chin-Ming; Chang, Hsien-Cheh; Kao, Shung-Te; Li, Tsai-Chung; Wei, Ching-Chuan; Chen, Chiachung; Liao, Yin-Tzu; Chen, Fun-Jou

    2011-01-01

    This study aims to explore the effects of heat and cold stress on the radial pressure pulse (RPP) and heart rate variability (HRV). The subjects immersed their left hand into 45°C and 7°C water for 2 minutes. Sixty healthy subjects (age 25 ± 4 yr; 29 men and 31 women) were enrolled in this study. All subjects underwent the supine temperature measurements of the bilateral forearms, brachial arterial blood pressure, HRV and RPP with a pulse analyzer in normothermic conditions, and thermal stresses. The power spectral low-frequency (LF) and high-frequency (HF) components of HRV decreased in the heat test and increased in the cold test. The heat stress significantly reduced radial augmentation index (AIr) (P < .05), but the cold stress significantly increased AIr (P < .01). The spectral energy of RPP did not show any statistical difference in 0 ~ 10 Hz region under both conditions, but in the region of 10 ~ 50 Hz, there was a significant increase (P < .01) in the heat test and a significant decrease in the cold test (P < .01). The changes in AIr induced by heat and cold stress were significantly negatively correlated with the spectral energy in the region of 10 ~ 50 Hz (SE10−50 Hz) but not in the region of 0 ~ 10 Hz (SE0−10 Hz). The results demonstrated that the SE10−50 Hz, which only possessed a small percentage in total pulse energy, presented more physiological characteristics than the SE0−10 Hz under the thermal stresses. PMID:21113292

  11. Apollo's Warriors: US Air Force Special Operations during the Cold War

    National Research Council Canada - National Science Library

    Hass, Michael

    1997-01-01

    .... Attempting to capture the history of USAF special operations from the beginning of the cold war to the end of the Second Indochina War is an exercise in humility the historian's worst nightmare in some respects...

  12. Analytical model of heat transfer in porous insulation around cold pipes

    DEFF Research Database (Denmark)

    Guldbrandsen, Tom; Karlsson, Per W.; Korsgaard, Vagn

    2011-01-01

    cloth is wrapped around the cold tube and extended through a slit in the tubular insulation and a slot in the facing to the ambient so that condensed water can evaporate into the air. Some of the moisture in that part of the wicking cloth situated in the slit in the tubular insulation will diffuse......A thermal insulation system is analysed that consists of a cold tube insulated with a porous material faced with a vapour retarding foil.Water vapour will diffuse through the vapour retarding foil and condense on the cold tube. To avoid build-up of water in the insulation a hydrophilic wicking...

  13. A coupled surface/subsurface flow model accounting for air entrapment and air pressure counterflow

    DEFF Research Database (Denmark)

    Delfs, Jens Olaf; Wang, Wenqing; Kalbacher, Thomas

    2013-01-01

    wave) shallow flow and two-phase flow in a porous medium. The simultaneous mass transfer between the soil, overland, and atmosphere compartments is achieved by upgrading a fully established leakance concept for overland-soil liquid exchange to an air exchange flux between soil and atmosphere. In a new...... algorithm, leakances operate as a valve for gas pressure in a liquid-covered porous medium facilitating the simulation of air out-break events through the land surface. General criteria are stated to guarantee stability in a sequential iterative coupling algorithm and, in addition, for leakances to control...

  14. TRPM8 mechanism of autonomic nerve response to cold in respiratory airway

    Directory of Open Access Journals (Sweden)

    Wang Cong-Yi

    2008-06-01

    Full Text Available Abstract Breathing cold air without proper temperature exchange can induce strong respiratory autonomic responses including cough, airway constriction and mucosal secretion, and can exacerbate existing asthma conditions and even directly trigger an asthma attack. Vagal afferent fiber is thought to be involved in the cold-induced respiratory responses through autonomic nerve reflex. However, molecular mechanisms by which vagal afferent fibers are excited by cold remain unknown. Using retrograde labeling, immunostaining, calcium imaging, and electrophysiological recordings, here we show that a subpopulation of airway vagal afferent nerves express TRPM8 receptors and that activation of TRPM8 receptors by cold excites these airway autonomic nerves. Thus activation of TRPM8 receptors may provoke autonomic nerve reflex to increase airway resistance. This putative autonomic response may be associated with cold-induced exacerbation of asthma and other pulmonary disorders, making TRPM8 receptors a possible target for prevention of cold-associated respiratory disorders.

  15. Effect of inspired air conditions on exercise-induced bronchoconstriction and urinary CC16 levels in athletes.

    Science.gov (United States)

    Bolger, C; Tufvesson, E; Anderson, S D; Devereux, G; Ayres, J G; Bjermer, L; Sue-Chu, M; Kippelen, P

    2011-10-01

    Injury to the airway epithelium has been proposed as a key susceptibility factor for exercise-induced bronchoconstriction (EIB). Our goals were to establish whether airway epithelial cell injury occurs during EIB in athletes and whether inhalation of warm humid air inhibits this injury. Twenty-one young male athletes (10 with a history of EIB) performed two 8-min exercise tests near maximal aerobic capacity in cold dry (4°C, 37% relative humidity) and warm humid (25°C, 94% relative humidity) air on separate days. Postexercise changes in urinary CC16 were used as a biomarker of airway epithelial cell perturbation and injury. Bronchoconstriction occurred in eight athletes in the cold dry environment and was completely blocked by inhalation of warm humid air [maximal fall in forced expiratory volume in 1 s = 18.1 ± 2.1% (SD) in cold dry air and 1.7 ± 0.8% in warm humid air, P air [median CC16 increase pre- to postchallenge = 1.91 and 0.35 ng/μmol in cold dry and warm humid air, respectively, in athletes with EIB (P = 0.017) and 1.68 and 0.48 ng/μmol in cold dry and warm humid air, respectively, in athletes without EIB (P = 0.002)]. The results indicate that exercise hyperpnea transiently disrupts the airway epithelium of all athletes (not only in those with EIB) and that inhalation of warm moist air limits airway epithelial cell perturbation and injury.

  16. Exhaust Emission Characteristics of Heavy Duty Diesel Engine During Cold and Warm Start

    Directory of Open Access Journals (Sweden)

    YANG Rong

    2014-07-01

    Full Text Available Through experiment conducted on a six cylinder direct injection diesel engine with SCR catalyst, effects of coolant temperature on rail pressure, injection quantity, excess air coefficient and emissions characteristics during cold and warm start were investigated. The results showed that, the maximum injection quantity during a starting event was several times higher than idling operation mode, so was the maximal opacity in the cold and warm starting process. When coolant temperature rose up to above 20℃, NOX emissions in the starting process exhibited peculiar rise which was times higher than idling mode. Compared with engine warm start, rail pressure, cycle fuel quantity, opacity, CO and HC emissions during engine cold start were higher in the course from their transient maximal values towards stabilized idling status. NOX in the same transient course, however, were lower in cold start. As coolant temperature rose, the maximal and the idling value of rail pressure and cycle fuel injection quantity during diesel engine starting process decreased gradually, the excess air coefficient increased to a certain degree, and the maximal and idling values of NOX increased gradually.

  17. Responses of sympathetic nervous system to cold exposure in vibration syndrome subjects and age-matched healthy controls.

    Science.gov (United States)

    Nakamoto, M

    1990-01-01

    Plasma norepinephrine and epinephrine in vibration syndrome subjects and age-matched healthy controls were measured for the purpose of estimating the responsibility of the sympathetic nervous system to cold exposure. In preliminary experiment, it was confirmed that cold air exposure of the whole body was more suitable than one-hand immersion in cold water. In the main experiment, 195 subjects were examined. Sixty-five subjects had vibration syndrome with vibration-induced white finger (VWF + group) and 65 subjects had vibration syndrome without VWF (VWF- group) and 65 controls had no symptoms (control group). In the three groups, plasma norepinephrine levels increased during cold air exposure of whole body at 7 degrees +/- 1.5 degrees C. Blood pressure increased and skin temperature decreased during cold exposure. Percent increase of norepinephrine in the VWF+ group was the highest while that in VWF- group followed and that in the control group was the lowest. This whole-body response of the sympathetic nervous system to cold conditions reflected the VWF which are characteristic symptoms of vibration syndrome. Excluding the effects of shivering and a cold feeling under cold conditions, it was confirmed that the sympathetic nervous system in vibration syndrome is activated more than in the controls. These results suggest that vibration exposure to hand and arm affects the sympathetic nervous system.

  18. Cost of a measles outbreak in a remote island economy: 2014 Federated States of Micronesia measles outbreak.

    Science.gov (United States)

    Pike, Jamison; Tippins, Ashley; Nyaku, Mawuli; Eckert, Maribeth; Helgenberger, Louisa; Underwood, J Michael

    2017-10-13

    After 20years with no reported measles cases, on May 15, 2014 the Centers for Disease Control and Prevention (CDC) was notified of two cases testing positive for measles-specific immunoglobulin M (IgM) antibodies in the Federated States of Micronesia (FSM). Under the Compact of Free Association, FSM receives immunization funding and technical support from the United States (US) domestic vaccination program managed by the Centers for Disease Control and Prevention (CDC). In a collaborative effort, public health officials and volunteers from FSM and the US government worked to respond and contain the measles outbreak through an emergency mass vaccination campaign, contact tracing, and other outbreak investigation activities. Contributions were also made by United Nations Children's Emergency Fund (UNICEF) and World Health Organization (WHO). Total costs incurred as a result of the outbreak were nearly $4,000,000; approximately $10,000 per case. Direct medical costs (≈$141,000) were incurred in the treatment of those individuals infected, as well as lost productivity of the infected and informal caregivers (≈$250,000) and costs to contain the outbreak (≈$3.5 million). We assessed the economic burden of the 2014 measles outbreak to FSM, as well as the economic responsibilities of the US. Although the US paid the majority of total costs of the outbreak (≈67%), examining each country's costs relative to their respective economy illustrates a far greater burden to FSM. We demonstrate that while FSM was heavily assisted by the US in responding to the 2014 Measles Outbreak, the outbreak significantly impacted their economy. FSM's economic burden from the outbreak is approximately equivalent to their entire 2016 Fiscal Year budget dedicated to education. Published by Elsevier Ltd.

  19. An outbreak of norovirus gastroenteritis associated with asymptomatic food handlers in Kinmen, Taiwan

    Directory of Open Access Journals (Sweden)

    Meng-Yu Chen

    2016-05-01

    Full Text Available Abstract Background In February 2015 an outbreak of gastroenteritis occurred in a distillery in Kinmen, Taiwan. At least 450 affected employees developed the symptoms of diarrhea and vomiting after attending a lunch banquet on 6 February. Epidemiological, laboratory and environmental investigations were conducted to identify the agent and source of this outbreak. Methods A case–control study was carried out among lunch attendees from the distillery. Using a semi-structured questionnaire, food and beverage consumption in the lunch banquet was assessed, as well as demographic and clinical data of the exposed people. An outbreak case was defined as a diner who developed at least three following symptoms: diarrhea, vomiting, abdominal pain, nausea, chills and/or weakness in the 72 h following the lunch. Controls were defined as lunch attendees who did not have any of the above symptoms. Rectal swabs or stool samples of the symptomatic exposed diners and food handlers as well as food and environmental samples were collected to test potential bacteria and viruses. Norovirus was detected by reverse transcription-polymerase chain reaction and sequence analysis. An environmental assessment, including environmental inspection of the restaurant and a review of work practices of food workers, was undertaken. Results Of 363 respondents with complete data, 169 met the case definition and 111 met the control definition. Consumption of pork liver in cold appetizers (adjusted odd ratio (aOR 3.23; 95 % confidence interval (CI: 1.26–8.30 and lamb chops (aOR: 3.98, 95 % CI: 1.74–9.11 were each associated with increased risk of illness. No cases but two asymptomatic food handlers who prepared or cooked the implicated foods tested positive for norovirus genotype I.6. Food and environmental samples were negative for any bacteria. Environmental assessment indicated that hand washing facilities were not properly accessible to food handlers. Inappropriate

  20. Adaptation of the continuous cold-trap system of fluidized-bed to the fluoride volatility process

    International Nuclear Information System (INIS)

    1976-01-01

    A continuous cold-trap system consisting of fluidized condensor and stripper has been evaluated with a view to adapt it to the Fluoride Volatility Process in establishing the continuous purification process without radiation decomposition of PuF 6 . Its feasibility is shown by the test with UF 6 -air. Necessary conditions for the cold trap, and performance of the 2-in.-dia. fluidized-bed cold-trap system are presented, and also a model of mist formation in the condensor

  1. Coccidioidomycosis Outbreaks, United States and Worldwide, 1940-2015.

    Science.gov (United States)

    Freedman, Michael; Jackson, Brendan R; McCotter, Orion; Benedict, Kaitlin

    2018-03-01

    Coccidioidomycosis causes substantial illness and death in the United States each year. Although most cases are sporadic, outbreaks provide insight into the clinical and environmental features of coccidioidomycosis, high-risk activities, and the geographic range of Coccidioides fungi. We identified reports published in English of 47 coccidioidomycosis outbreaks worldwide that resulted in 1,464 cases during 1940-2015. Most (85%) outbreaks were associated with environmental exposures; the 2 largest outbreaks resulted from an earthquake and a large dust storm. More than one third of outbreaks occurred in areas where the fungus was not previously known to be endemic, and more than half of outbreaks involved occupational exposures. Coccidioidomycosis outbreaks can be difficult to detect and challenging to prevent given the unknown effectiveness of environmental control methods and personal protective equipment; therefore, increased awareness of coccidioidomycosis outbreaks is needed among public health professionals, healthcare providers, and the public.

  2. How cold is cold dark matter?

    International Nuclear Information System (INIS)

    Armendariz-Picon, Cristian; Neelakanta, Jayanth T.

    2014-01-01

    If cold dark matter consists of particles, these must be non-interacting and non-relativistic by definition. In most cold dark matter models however, dark matter particles inherit a non-vanishing velocity dispersion from interactions in the early universe, a velocity that redshifts with cosmic expansion but certainly remains non-zero. In this article, we place model-independent constraints on the dark matter temperature to mass ratio, whose square root determines the dark matter velocity dispersion. We only assume that dark matter particles decoupled kinetically while non-relativistic, when galactic scales had not entered the horizon yet, and that their momentum distribution has been Maxwellian since that time. Under these assumptions, using cosmic microwave background and matter power spectrum observations, we place upper limits on the temperature to mass ratio of cold dark matter today (away from collapsed structures). These limits imply that the present cold dark matter velocity dispersion has to be smaller than 54 m/s. Cold dark matter has to be quite cold, indeed

  3. Effects of cold fronts on ozone in the Houston-Galveston-Brazoria Area

    Science.gov (United States)

    Lei, R.; Talbot, R. W.; Wang, Y.; Wang, S. C.; Estes, M. J.

    2017-12-01

    A cold front may have confounding effects on ozone by bringing in contaminated air masses to an area and causing lower temperatures which likely lead to low ozone production rates. Literature reports on individual cold front events showing increasing and decreasing effects on ozone. The Houston-Galveston-Brazoria (HGB) area as the energy capital of USA suffers relatively high ozone levels. The effect of cold fronts on HGB ozone in the long-term range remains unknown. Weather Prediction Center (WPC) Surface Analysis Archive from National Oceanic and Atmospheric Administration (NOAA) which records cold fronts' positions since 2003 has been employed in this study. The results show the count of cold fronts passing the HGB area shows no clear trend but great interannual variation. Cold front appearance in summer is much less than in other seasons. In general, both mean MDA8 and background ozone during cold front days increased compared non-cold front days. This increasing effect has been enhanced during post-front days and summer season. Cluster analysis on meteorological parameters shows cold front days with high precipitation or wind speed could lower the MDA8 and background ozone but the proportion of those days are low in all cold front days. It may explain why cold fronts show increasing effects on ozone in the HGB area.

  4. Cold Antimatter Plasmas, and Aspirations for Cold Antihydrogen

    Science.gov (United States)

    2002-06-24

    UNCLASSIFIED Defense Technical Information Center Compilation Part Notice ADP012494 TITLE: Cold Antimatter Plasmas, and Aspirations for Cold...part numbers comprise the compilation report: ADP012489 thru ADP012577 UNCLASSIFIED Cold Antimatter Plasmas, and Aspirations for Cold Antihydrogen G...and positrons. The antiprotons come initially from the new Antiproton Decel- erator facility at CERN. Good control of such cold antimatter plasmas is

  5. Cold Vacuum Drying facility personnel monitoring system design description (SYS 12); FINAL

    International Nuclear Information System (INIS)

    PITKOFF, C.C.

    1999-01-01

    This document describes the Cold Vacuum Drying Facility (CVDF) instrument air (IA) system that provides instrument quality air to the CVDF. The IA system provides the instrument quality air used in the process, HVAC, and HVAC instruments. The IA system provides the process skids with air to aid in the purging of the annulus of the transport cask. The IA system provides air for the solenoid-operated valves and damper position controls for isolation, volume, and backdraft in the HVAC system. The IA system provides air for monitoring and control of the HVAC system, process instruments, gas-operated valves, and solenoid-operated instruments. The IA system also delivers air for operating hand tools in each of the process bays

  6. Foodborne gastroenteritis outbreak in an Austrian healthcare facility caused by asymptomatic, norovirus-excreting kitchen staff.

    Science.gov (United States)

    Schmid, D; Kuo, H-W; Hell, M; Kasper, S; Lederer, I; Mikula, C; Springer, B; Allerberger, F

    2011-03-01

    An outbreak of norovirus GGII.4 2006b affected an Austrian 600-bed healthcare facility from 15 to 27 March 2009. A total of 204 patients, residents and staff fitted the outbreak case definition; 17 (8.3%) were laboratory-confirmed. Foodborne origin was suspected in the 114 patient and resident cases with onset 15-18 March. A case-cohort study was performed to test the hypothesis that consumption of dishes offered on 14, 15 and 16 March (risk days) was associated with increased risk of infection. Data on food exposure of 62% (317/510) of the patient and resident cohort were available for a simultaneous retrospective cohort study. The case-cohort analysis revealed that consumption of sliced cold sausage offered on 15 March [odds ratio (OR): 3.98; 95% confidence interval (CI): 1.18-14.1], a meat dish with salad (adjusted OR: 2.2; 95% CI: 1.19-4.08) and a rolled spinach pancake (adjusted OR: 2.17; 95% CI: 1.27-3.71) on 16 March were independent risk factors. It is likely that one of the five asymptomatic excretors among the kitchen staff on duty on the risk days was the source of food contamination. The case-cohort study design was found to be a valid alternative to the retrospective cohort study design for the investigation of a suspected foodborne outbreak in a large cohort. Copyright © 2010 The Hospital Infection Society. Published by Elsevier Ltd. All rights reserved.

  7. Adaptation of the continuous cold trap system of fluidized-bed to the fluoride volatility process

    International Nuclear Information System (INIS)

    1976-02-01

    A continuous cold trap system consisting of fluidized condenser and stripper has been evaluated with a view to adapt it to the Fluoride Volatility Process in establishing the continuous purification process without radiation decomposition of PuF 6 . Its feasibility is shown by the test with UF 6 -air. Necessary conditions for the cold trap, and performance of the two inch-dia. fluidized bed cold trap system are presented, and also a model of mist formation in the condenser. (auth.)

  8. Air quality and exercise-induced bronchoconstriction in elite athletes.

    Science.gov (United States)

    Rundell, Kenneth W; Sue-Chu, Malcolm

    2013-08-01

    A higher prevalence of airway hyperresponsiveness, airway remodeling, and asthma has been identified among athletes who compete and train in environmental conditions of cold dry air and/or high air pollution. Repeated long-duration exposure to cold/dry air at high minute ventilation rates can cause airway damage. Competition or training at venues close to busy roadways, or in indoor ice arenas or chlorinated swimming pools, harbors a risk for acute and chronic airway disorders from high pollutant exposure. This article discusses the effects of these harsh environments on the airways, and summarizes potential mechanisms and prevalence of airway disorders in elite athletes. Copyright © 2013 Elsevier Inc. All rights reserved.

  9. Application and verification of cold air velocity technique for solving tube ash erosion problem in PC boilers

    Energy Technology Data Exchange (ETDEWEB)

    Yoo, Kisoo; Jeong, Kwon Seok [Korea Southern Power Corporation, Gimhae (Korea, Republic of)

    2012-06-15

    Fly ash erosion is a leading cause of boiler tube failure in PC boilers. Therefore, shields or baffle plates are installed in specific areas to mitigate fly ash erosion and prevent boiler tube failure. However, the tube failure problems caused by fly ash erosion cannot be eliminated with this solution alone, because each PC boiler has a different flue gas flow pattern and erosion can become severe in unexpected zones. This problem is caused by an asymmetric internal flow velocity and local growth of the flue gas velocity. For these reasons, clearly defining the flow pattern in PC boilers is important for solving the problem of tube failure caused by fly ash erosion. For this purpose, the cold air velocity technique (CAVT) can be applied to the fly ash erosion problem. In this study, CAVT was carried out on the Hadong 2 PC boiler and the feasibility of application of CAVT to conventional PC boilers was validated.

  10. Application and verification of cold air velocity technique for solving tube ash erosion problem in PC boilers

    International Nuclear Information System (INIS)

    Yoo, Kisoo; Jeong, Kwon Seok

    2012-01-01

    Fly ash erosion is a leading cause of boiler tube failure in PC boilers. Therefore, shields or baffle plates are installed in specific areas to mitigate fly ash erosion and prevent boiler tube failure. However, the tube failure problems caused by fly ash erosion cannot be eliminated with this solution alone, because each PC boiler has a different flue gas flow pattern and erosion can become severe in unexpected zones. This problem is caused by an asymmetric internal flow velocity and local growth of the flue gas velocity. For these reasons, clearly defining the flow pattern in PC boilers is important for solving the problem of tube failure caused by fly ash erosion. For this purpose, the cold air velocity technique (CAVT) can be applied to the fly ash erosion problem. In this study, CAVT was carried out on the Hadong 2 PC boiler and the feasibility of application of CAVT to conventional PC boilers was validated

  11. Patients' experiences of cold exposure during ambulance care.

    Science.gov (United States)

    Aléx, Jonas; Karlsson, Stig; Saveman, Britt-Inger

    2013-06-06

    Exposure to cold temperatures is often a neglected problem in prehospital care. Cold exposure increase thermal discomfort and, if untreated causes disturbances of vital body functions until ultimately reaching hypothermia. It may also impair cognitive function, increase pain and contribute to fear and an overall sense of dissatisfaction. The aim of this study was to investigate injured and ill patients' experiences of cold exposure and to identify related factors. During January to March 2011, 62 consecutively selected patients were observed when they were cared for by ambulance nursing staff in prehospital care in the north of Sweden. The field study was based on observations, questions about thermal discomfort and temperature measurements (mattress air and patients' finger temperature). Based on the observation protocol the participants were divided into two groups, one group that stated it was cold in the patient compartment in the ambulance and another group that did not. Continuous variables were analyzed with independent sample t-test, paired sample t-test and dichotomous variables with cross tabulation. In the ambulance 85% of the patients had a finger temperature below comfort zone and 44% experienced the ambient temperature in the patient compartment in the ambulance to be cold. There was a significant decrease in finger temperature from the first measurement indoor compared to measurement in the ambulance. The mattress temperature at the ambulance ranged from -22.3°C to 8.4°C. Cold exposure in winter time is common in prehospital care. Sick and injured patients immediately react to cold exposure with decreasing finger temperature and experience of discomfort from cold. Keeping the patient in the comfort zone is of great importance. Further studies are needed to increase knowledge which can be a base for implications in prehospital care for patients who probably already suffer for other reasons.

  12. Patients’ experiences of cold exposure during ambulance care

    Science.gov (United States)

    2013-01-01

    Background Exposure to cold temperatures is often a neglected problem in prehospital care. Cold exposure increase thermal discomfort and, if untreated causes disturbances of vital body functions until ultimately reaching hypothermia. It may also impair cognitive function, increase pain and contribute to fear and an overall sense of dissatisfaction. The aim of this study was to investigate injured and ill patients’ experiences of cold exposure and to identify related factors. Method During January to March 2011, 62 consecutively selected patients were observed when they were cared for by ambulance nursing staff in prehospital care in the north of Sweden. The field study was based on observations, questions about thermal discomfort and temperature measurements (mattress air and patients’ finger temperature). Based on the observation protocol the participants were divided into two groups, one group that stated it was cold in the patient compartment in the ambulance and another group that did not. Continuous variables were analyzed with independent sample t-test, paired sample t-test and dichotomous variables with cross tabulation. Results In the ambulance 85% of the patients had a finger temperature below comfort zone and 44% experienced the ambient temperature in the patient compartment in the ambulance to be cold. There was a significant decrease in finger temperature from the first measurement indoor compared to measurement in the ambulance. The mattress temperature at the ambulance ranged from −22.3°C to 8.4°C. Conclusion Cold exposure in winter time is common in prehospital care. Sick and injured patients immediately react to cold exposure with decreasing finger temperature and experience of discomfort from cold. Keeping the patient in the comfort zone is of great importance. Further studies are needed to increase knowledge which can be a base for implications in prehospital care for patients who probably already suffer for other reasons. PMID:23742143

  13. Gastroenteritis outbreaks on cruise ships

    DEFF Research Database (Denmark)

    Mouchtouri, Varvara A; Verykouki, Eleni; Zamfir, Dumitru

    2017-01-01

    When an increased number of acute gastroenteritis (AG) cases is detected among tourists staying at the same accommodation, outbreak management plans must be activated in a timely manner to prevent large outbreaks. Syndromic surveillance data collected between 1 January 2010 and 31 December 2013...

  14. Decreasing but still significant facilitation effect of cold-season macrophytes on wetlands purification function during cold winter.

    Science.gov (United States)

    Zou, Xiangxu; Zhang, Hui; Zuo, Jie; Wang, Penghe; Zhao, Dehua; An, Shuqing

    2016-06-01

    To identify the facilitation effect of a cool-season aquatic macrophyte (FEam) for use in effluent purification via constructed floating wetlands (CFWs) and to determine the possible pathways used during a winter period with an average temperature of less than 5 °C, pilot-scale CFWs were planted with the cold-season macrophyte Oenanthe clecumbens and were operated as batch systems. Although some leaves withered, the roots retained relatively high levels of activity during the winter, which had average air and water temperatures of 3.63 and 5.04 °C, respectively. The N and P removal efficiencies in CFWs decreased significantly in winter relative to those in late autumn. The presence of cool-season plants resulted in significant improvements in N and P removal, with a FEam of 15.23-25.86% in winter. Microbial N removal accounted for 71.57% of the total N removed in winter, and the decrease in plant uptake was the dominant factor in the wintertime decrease in N removal relative to that in late autumn. These results demonstrate the importance of cold-season plants in CFWs for the treatment of secondary effluent during cold winters.

  15. Cold Stress

    Science.gov (United States)

    ... Publications and Products Programs Contact NIOSH NIOSH COLD STRESS Recommend on Facebook Tweet Share Compartir Workers who ... cold environments may be at risk of cold stress. Extreme cold weather is a dangerous situation that ...

  16. Atmospheric pressure cold plasma as an antifungal therapy

    International Nuclear Information System (INIS)

    Sun Peng; Wu Haiyan; Sun Yi; Liu Wei; Li Ruoyu; Zhu Weidong; Lopez, Jose L.; Zhang Jue; Fang Jing

    2011-01-01

    A microhollow cathode based, direct-current, atmospheric pressure, He/O 2 (2%) cold plasma microjet was used to inactive antifungal resistants Candida albicans, Candida krusei, and Candida glabrata in air and in water. Effective inactivation (>90%) was achieved in 10 min in air and 1 min in water. Antifungal susceptibility tests showed drastic reduction of the minimum inhibitory concentration after plasma treatment. The inactivation was attributed to the reactive oxygen species generated in plasma or in water. Hydroxyl and singlet molecular oxygen radicals were detected in plasma-water system by electron spin resonance spectroscopy. This approach proposed a promising clinical dermatology therapy.

  17. In China, students in crowded dormitories with a low ventilation rate have more common colds: evidence for airborne transmission.

    Directory of Open Access Journals (Sweden)

    Yuexia Sun

    Full Text Available OBJECTIVE: To test whether the incidence of common colds among college students in China is associated with ventilation rates and crowdedness in dormitories. METHODS: In Phase I of the study, a cross-sectional study, 3712 students living in 1569 dorm rooms in 13 buildings responded to a questionnaire about incidence and duration of common colds in the previous 12 months. In Phase II, air temperature, relative humidity and CO(2 concentration were measured for 24 hours in 238 dorm rooms in 13 buildings, during both summer and winter. Out-to indoor air flow rates at night were calculated based on measured CO(2 concentrations. RESULTS: In Phase I, 10% of college students reported an incidence of more than 6 common colds in the previous 12 months, and 15% reported that each infection usually lasted for more than 2 weeks. Students in 6-person dorm rooms were about 2 times as likely to have an incidence of common colds ≥6 times per year and a duration ≥2 weeks, compared to students in 3-person rooms. In Phase II, 90% of the measured dorm rooms had an out-to indoor air flow rate less than the Chinese standard of 8.3 L/s per person during the heating season. There was a dose-response relationship between out-to indoor air flow rate per person in dorm rooms and the proportion of occupants with annual common cold infections ≥6 times. A mean ventilation rate of 5 L/(s•person in dorm buildings was associated with 5% of self reported common cold ≥6 times, compared to 35% at 1 L/(s•person. CONCLUSION: Crowded dormitories with low out-to indoor airflow rates are associated with more respiratory infections among college students.

  18. Measles outbreak linked to European B3 outbreaks, Wales, United Kingdom, 2017.

    Science.gov (United States)

    Currie, Jonny; Davies, Llion; McCarthy, Joanne; Perry, Malorie; Moore, Catherine; Cottrell, Simon; Bowley, Mererid; Williams, Chris; Shankar, Ananda Giri; Stiff, Rhianwen

    2017-10-01

    The United Kingdom achieved interrupted endemic measles transmission for 36 months in 2016. Despite this, ongoing challenges from sporadic measles cases typically imported from abroad remain. We summarise a B3 measles genotype outbreak in south-east Wales occurring between May and September 2017, linked with other European outbreaks, and lessons learnt. Seventeen confirmed cases and one probable case occurred principally in education and healthcare-settings. Six confirmed cases attended healthcare settings when infectious, without being isolated.

  19. Epidemiological study of air filtration systems for preventing PRRSV infection in large sow herds.

    Science.gov (United States)

    Alonso, Carmen; Murtaugh, Michael P; Dee, Scott A; Davies, Peter R

    2013-10-01

    Porcine reproductive and respiratory syndrome virus (PRRSV) is the most economically significant pathogen in the US swine industry. Aerosol transmission among herds is a major concern in pig dense regions and filtration of incoming air, in combination with standard biosecurity procedures, has been demonstrated to prevent transmission of PRRSV into susceptible herds. To quantify the impact of air filtration on reducing risk of PRRSV outbreaks, we compared the incidence rate of new PRRSV introductions in 20 filtered and 17 non-filtered control sow herds in a swine dense region of North America during a 7 year study period. Events of novel virus introduction were ascertained by phylogenetic analysis of PRRSV ORF5 gene sequences. Putative new viruses were defined as exogenous (introduced) based on ORF5 nucleotide sequence differences compared to previous farm isolates. The influence of sequence difference cut-off values ranging from 2 to 10% on case definition and relative risk were evaluated. Non-filtered farms incurred about 0.5 outbreaks per year, with a seasonal increase in risk in cooler periods. Baseline risk, prior to filtration, in treatment farms was approximately 0.75 per year, approximately 50% higher than in control farms. Air filtration significantly reduced risk of PRRSV introduction events to 0.06-0.22 outbreaks per year, depending on the cut-off values used to classify a virus isolate as new to the herd. Overall, air filtration led to an approximately 80% reduction in risk of introduction of novel PRRSV, indicating that on large sow farms with good biosecurity in swine-dense regions, approximately four-fifths of PRRSV outbreaks may be attributable to aerosol transmission. Copyright © 2013 Elsevier B.V. All rights reserved.

  20. Hospital-acquired infections associated with poor air quality in air-conditioned environments

    Directory of Open Access Journals (Sweden)

    Daniela Pinheiro da Silva

    2013-10-01

    Full Text Available Backgound and Objectives: Individuals living in cities increasingly spend more time indoors in air-conditioned environments. Air conditioner contamination can be caused by the presence of aerosols from the external or internal environment, which may be associated with disease manifestations in patients present in this type of environment. Therefore, the aim of this review was to assess the air quality in air-conditioned hospital environments as a risk factor for hospital-acquired infections – HAI – as the air can be a potential source of infection, as well as assess the exposure of professionals and patients to different pollutants. Material and Methods: A literature review was performed in the LILACS, MEDLINE, SCIELO, SCIENCE DIRECT databases, CAPES thesis database and Ministry of Health – Brazil, including studies published between 1982 and 2008. The literature search was grouped according to the thematic focus, as follows: ventilation, maintenance and cleaning of systems that comprehend the environmental quality standard. Discussion and Conclusion: Outbreaks of hospital-acquired infections associated with Aspergillus, Acinetobacter, Legionella, and other genera such as Clostridium and Nocardia, which were found in air conditioners, were observed, thus indicating the need for air-conditioning quality control in these environments.

  1. Delineation of frost characteristics on cold walls by using a new formula for psychrometrics demarcation boundary

    International Nuclear Information System (INIS)

    Ali, Ahmed Hamza H.

    2009-01-01

    In this study, a direct formula that predicts either the frost formation on cold walls is correspondence to psychrometric-subsaturated or supersaturated regions is presented. The developed formula uses the data of the entering air dry-bulb temperature and absolute humidity, and the absolute humidity of the air at saturation corresponding to the coil surface temperature. Cases studies of demarcation criteria for frost formation on evaporator coil using experimental measured data, and on walls of cold storage freezer using measured data from literature are used to validate the formula and it is found that results are completely matches to the graphic plot of the data on the psychrometric chart. In case of cold storage freezers, the result clearly shows that a greater demarcation criteria value indicates frost formation under sever condition that is characterized as snow-like with low density and thermal conductivity.

  2. Typhoid fever: A report on a point-source outbreak of 69 cases in Cape Town.

    Science.gov (United States)

    Popkiss, M E

    1980-03-01

    In 1978, after a party in a Cape Town suburb attended by several hundred people, 69 persons were treated for typhoid fever. The precise source of the infection could not be traced, although it is reasonable to suppose that food eaten at the party had been contaminated by the main caterer. All 57 cultures of Salmonella typhi phage-typed were of phage type 46, including that obtained from the stool of the main caterer, who was asymptomatic. An epidemiological profile of the cases and an account of the management of the outbreak is given. There were no deaths and no patient became a carrier. Although the outbreak was contained, certain problems relating thereto are aired, including in particular the potential hazard of food-borne disease wherever housing and environmental standards are low.

  3. Norovirus: U.S. Trends and Outbreaks

    Science.gov (United States)

    ... harvested from contaminated water and raspberries irrigated with contaminated water have caused norovirus outbreaks. Norovirus on Cruise Ships Over 90% of diarrheal disease outbreaks on cruise ships are caused by norovirus ( ...

  4. Establishing a milkborne disease outbreak profile: potential food defense implications.

    Science.gov (United States)

    Newkirk, Ryan; Hedberg, Craig; Bender, Jeff

    2011-03-01

    The main objectives of this study were to establish baseline characteristics for milkborne outbreaks, establish an expected milkborne outbreak profile, and identify potential indicators of food terrorism. This study used 1990-2006 data from the Centers for Disease Control and Prevention Annual Listings of Disease Outbreaks and the Foodborne Outbreak Database (FOOD) to establish epidemiologic baseline characteristics for disease outbreaks associated with fluid milk. FOOD data from 2007 were used to qualitatively validate the potential of the baseline characteristics and the expected outbreak profile. Eighty-three fluid milkborne outbreaks were reported between 1990 and 2006, resulting in 3621 illnesses. The mean number of illnesses per outbreak was 43.6 (illness range: 2-1644). Consumption of unpasteurized milk was associated with 55.4% of reported outbreaks. Campylobacter spp., Escherichia coli, and Salmonella spp. caused 51.2%, 10.8%, and 9.6% of reported outbreaks, respectively. Private homes accounted for 41.0% of outbreak locations. Number ill, outbreak location, and etiology were the primary characteristics which could signal a potential intentional contamination event. In 2007, one pasteurized milk outbreak caused by Listeria was flagged as aberrative compared with the expected outbreak profile. The creation and dissemination of expected outbreak profiles and epidemiologic baseline characteristics allow public health and Homeland Security officials to quickly assess the potential of intentional food contamination. A faster public health and medical system response can result in decreased morbidity and mortality.

  5. Cold Vacuum Drying facility condensate collection system design description

    International Nuclear Information System (INIS)

    PITKOFF, C.C.

    1999-01-01

    This document describes the Cold Vacuum Drying Facility (CVDF) condensate collection system (CCS). The function of the CCS is to collect cooling coil condensate from air-handling units in the CVDF and to isolate the condensate in collection tanks until the condensate is determined to be acceptable to drain to the effluent drain collection basin

  6. Epidemiology of restaurant-associated foodborne disease outbreaks, United States, 1998-2013.

    Science.gov (United States)

    Angelo, K M; Nisler, A L; Hall, A J; Brown, L G; Gould, L H

    2017-02-01

    Although contamination of food can occur at any point from farm to table, restaurant food workers are a common source of foodborne illness. We describe the characteristics of restaurant-associated foodborne disease outbreaks and explore the role of food workers by analysing outbreaks associated with restaurants from 1998 to 2013 reported to the Centers for Disease Control and Prevention's Foodborne Disease Outbreak Surveillance System. We identified 9788 restaurant-associated outbreaks. The median annual number of outbreaks was 620 (interquartile range 618-629). In 3072 outbreaks with a single confirmed aetiology reported, norovirus caused the largest number of outbreaks (1425, 46%). Of outbreaks with a single food reported and a confirmed aetiology, fish (254 outbreaks, 34%) was most commonly implicated, and these outbreaks were commonly caused by scombroid toxin (219 outbreaks, 86% of fish outbreaks). Most outbreaks (79%) occurred at sit-down establishments. The most commonly reported contributing factors were those related to food handling and preparation practices in the restaurant (2955 outbreaks, 61%). Food workers contributed to 2415 (25%) outbreaks. Knowledge of the foods, aetiologies, and contributing factors that result in foodborne disease restaurant outbreaks can help guide efforts to prevent foodborne illness.

  7. Air-sea heat flux control on the Yellow Sea Cold Water Mass intensity and implications for its prediction

    Science.gov (United States)

    Zhu, Junying; Shi, Jie; Guo, Xinyu; Gao, Huiwang; Yao, Xiaohong

    2018-01-01

    The Yellow Sea Cold Water Mass (YSCWM), which occurs during summer in the central Yellow Sea, plays an important role in the hydrodynamic field, nutrient cycle and biological species. Based on water temperature observations during the summer from 1978 to 1998 in the western Yellow Sea, five specific YSCWM years were identified, including two strong years (1984 and 1985), two weak years (1989 and 1995) and one normal year (1992). Using a three-dimensional hydrodynamic model, the YSCWM formation processes in these five years were simulated and compared with observations. In general, the YSCWM began forming in spring, matured in summer and gradually disappeared in autumn of every year. The 8 °C isotherm was used to indicate the YSCWM boundary. The modelled YSCWM areas in the two strong years were approximately two times larger than those in the two weak years. Based on the simulations in the weak year of 1995, ten numerical experiments were performed to quantify the key factors influencing the YSCWM intensity by changing the initial water condition in the previous autumn, air-sea heat flux, wind, evaporation, precipitation and sea level pressure to those in the strong year of 1984, respectively. The results showed that the air-sea heat flux was the dominant factor influencing the YSCWM intensity, which contributed about 80% of the differences of the YSCWM average water temperature at a depth of 50 m. In addition, the air-sea heat flux in the previous winter had a determining effect, contributing more than 50% of the differences between the strong and weak YSCWM years. Finally, a simple formula for predicting the YSCWM intensity was established by using the key influencing factors, i.e., the sea surface temperature before the cooling season and the air-sea heat flux during the cooling season from the previous December to the current February. With this formula, instead of a complicated numerical model, we were able to roughly predict the YSCWM intensity for the

  8. EFFECTS OF USING PHASE CHANGE MATERIALS ON THE COLD START EXHAUST EMİSSİONS CHARACTERİSTİCS OF DIESEL ENGINES

    Directory of Open Access Journals (Sweden)

    Ferhat Kaya

    2016-05-01

    Full Text Available During the last two decades, the diesel engine performance and drivability have significantly improved with the latest technologic developments. Nevertheless, one of the disadvantageous of diesel engines is related to the difficulties for starting at cold conditions, particularly in the conditions where the ambient temperature is near or below 0ºC. Additionally, the harmful exhaust emissions are also at significantly important levels during the cold start conditions. Most of carbon monoxide (CO emissions from diesel engines are produced during the engine warm-up period.  In order to improve cold start characteristics of diesel engines, many measures have been proposed, such as glow plugs and air heaters in air intake lines.In this study, in order to increase the cold start performance and improve the exhaust emission characteristics of a direct injection diesel engine, phase change materials (PCMs have been used.PCMs have high heats of fusion and they can absorb latent energy before melting. During the phase change, temperature of PCMs remains nearly constant. In this study, a PCMs was used with the 45-51ºC melting temperature band in a heat exchanger. Hot water from an external source was circulated in the exchanger to carry out the experiments in the same conditions and was used as heat source in order to melt the PCMs.Engine intake air has been passed through the exchanger before engine intake manifold.  During the engine cooling period, the PCM in the produced heat exchanger have increased the cooling time period of engine intake air.An experimental setup has been established to observe the cold start characteristics of the two cylinder diesel engine with and without using the produced exchanger. Temperature measurements from different points, CO exhaust emissions, engine speed and in cylinder pressure measurements have been used to evaluate the contribution of exchanger and increasing the intake air temperature by using the PCMs. The

  9. Surveillance for foodborne disease outbreaks - United States, 1998-2008.

    Science.gov (United States)

    Gould, L Hannah; Walsh, Kelly A; Vieira, Antonio R; Herman, Karen; Williams, Ian T; Hall, Aron J; Cole, Dana

    2013-06-28

    Foodborne diseases cause an estimated 48 million illnesses each year in the United States, including 9.4 million caused by known pathogens. Foodborne disease outbreak surveillance provides valuable insights into the agents and foods that cause illness and the settings in which transmission occurs. CDC maintains a surveillance program for collection and periodic reporting of data on the occurrence and causes of foodborne disease outbreaks in the United States. This surveillance system is the primary source of national data describing the numbers of illnesses, hospitalizations, and deaths; etiologic agents; implicated foods; contributing factors; and settings of food preparation and consumption associated with recognized foodborne disease outbreaks in the United States. 1998-2008. The Foodborne Disease Outbreak Surveillance System collects data on foodborne disease outbreaks, defined as the occurrence of two or more cases of a similar illness resulting from the ingestion of a common food. Public health agencies in all 50 states, the District of Columbia, U.S. territories, and Freely Associated States have primary responsibility for identifying and investigating outbreaks and use a standard form to report outbreaks voluntarily to CDC. During 1998-2008, reporting was made through the electronic Foodborne Outbreak Reporting System (eFORS). During 1998-2008, CDC received reports of 13,405 foodborne disease outbreaks, which resulted in 273,120 reported cases of illness, 9,109 hospitalizations, and 200 deaths. Of the 7,998 outbreaks with a known etiology, 3,633 (45%) were caused by viruses, 3,613 (45%) were caused by bacteria, 685 (5%) were caused by chemical and toxic agents, and 67 (1%) were caused by parasites. Among the 7,724 (58%) outbreaks with an implicated food or contaminated ingredient reported, 3,264 (42%) could be assigned to one of 17 predefined commodity categories: fish, crustaceans, mollusks, dairy, eggs, beef, game, pork, poultry, grains/beans, oils

  10. Reporting and Surveillance for Norovirus Outbreaks

    Science.gov (United States)

    ... Vaccine Surveillance Network (NVSN) Foodborne Diseases Active Surveillance Network (FoodNet) National Outbreak Reporting System (NORS) Estimates of Foodborne Illness in the United States CDC's Vessel Sanitation Program CDC Feature: Surveillance for Norovirus Outbreaks Top ...

  11. Cold episodes in the Peruvian Central Andes: Composites, Types, and their Impacts over South America (1958-2014)

    Science.gov (United States)

    Sulca, J. C.; Vuille, M. F.; Roundy, P. E.; Trasmonte, G.; Silva, Y.; Takahashi, K.

    2015-12-01

    The Mantaro basin (MB) is located in the central Peruvian Andes. Occasionally, cold episodes are observed during austral summer (January-March), that strongly damage crops. However, little is known about the causes and impacts of such cold episodes. The main goal of this study is thus to characterize cold episodes in the MB and assess their large-scale circulation and teleconnections over South America (SA) during austral summer. To identify cold events in the MB daily minimum temperature (Tmin) for the period 1958-2014 from Huayao station, located within the MB was used. A cold episode is defined when daily minimum temperature drops below its 10-percentile for at least one day. Additionally, to study the sensitivity between physical mechanisms associated with cold episodes and temperature, cold episodes are classified in three groups: Weak cold episodes (7.5 ≤ Tmin ≤ 10 percentile), strong cold episodes (Tmin ≤ 2.5 percentile), but excluding the 9 coldest events (Tmin ≤ 0 ͦ C), henceforth referred to as extraordinary cold episodes. Several gridded reanalysis were used to characterize the large-scale circulation, cloud cover and rainfall over SA associated with these events. Weak and strong cold episodes in the MB are mainly associated with a weakening of the Bolivian High-Nordeste Low system by tropical-extratropical interactions. Both types of cold episodes are associated with westerly wind anomalies at mid- and upper-tropospheric levels aloft the Peruvian Central Andes, which inhibit the influx of humid air masses from the lowlands to the east and hence limit the development of cloud cover (e.g., positive OLR anomalies over MB). The resulting clear sky conditions cause nighttime temperatures to drop, leading to cold extremes below 10-percentile. Simultaneously, northeastern Brazil (NEB) registers negative OLR anomalies, strong convection and enhanced cloud cover because displacement of the South Atlantic Convergence Zone (SACZ) toward the northeast of

  12. Development of a compound energy system for cold region houses using small-scale natural gas cogeneration and a gas hydrate battery

    International Nuclear Information System (INIS)

    Obara, Shin'ya; Kikuchi, Yoshinobu; Ishikawa, Kyosuke; Kawai, Masahito; Yoshiaki, Kashiwaya

    2015-01-01

    In this study, an independent energy system for houses in cold regions was developed using a small-scale natural gas CGS (cogeneration), air-source heat pump, heat storage tank, and GHB (gas hydrate battery). Heat sources for the GHB were the ambient air and geothermal resources of the cold region. The heat cycle of CO 2 hydrate as a source of energy was also experimentally investigated. To increase the formation speed of CO 2 hydrates, a ferrous oxide–graphite system catalyst was used. The ambient air of cold regions was used as a heat source for the formation process (electric charge) of the GHB, and the heat supplied by a geothermal heat exchanger was used for the dissociation process (electric discharge). Using a geothermal heat source, fuel consumption was halved because of an increased capacity for hydrate formation in the GHB, a shortening of the charging and discharging cycle, and a decrease in the freeze rate of hydrate formation space. Furthermore, when the GHB was introduced into a cold region house, the application rate of renewable energy was 47–71% in winter. The spread of the GHB can greatly reduce fossil fuel consumption and the associated greenhouse gases released from houses in cold regions. - Highlights: • Compound energy system for cold region houses by a gas hydrate battery was proposed. • Heat sources of a gas hydrate battery are exhaust heat of the CGS and geothermal. • Drastic reduction of the fossil fuel consumption in a cold region is realized

  13. Cold tolerance evaluation in Chilean rice genotypes at the germination stage

    Directory of Open Access Journals (Sweden)

    Gabriel Donoso Ñanculao

    2013-03-01

    Full Text Available Low temperature is the most important abiotic stress affecting rice (Oryza sativa L. yield in Chile. Rice in Chile is usually planted when the minimum air temperatures are below 12 °C. This temperature is lower than the optimum needed for normal rice germination. Therefore, the aim of this study was to evaluate cold tolerance in 20 experimental lines from the Rice Breeding Program of the Instituto de Investigaciones Agropecuarias (INIA, Chile, at the germination stage. Coleoptile length reduction (CRED, coleoptile length after cold treatment (CLEN, coleoptile length recovery (CREC, and coleoptile regrowth (CREG were evaluated at 13 °C for 4 d using 'Diamante-INIA' as the cold-tolerant control. To find genotypes with cold tolerance (low CRED value and high CLEN, CREC, and CREG values, genotypes were ranked, a biplot of principal components, and cluster analysis were performed. No differences were found among genotypes in the ranking based on CREC value so this trait was not considered. Analysis showed that only three experimental lines had cold tolerance similar to that of 'Diamante-INIA'; all other experimental lines exhibited intermediate to low cold tolerance. These results showed low cold tolerance of some Chilean genotypes at the germination stage, thus confirming the need to evaluate the rest of the germplasm from the Rice Breeding Program.

  14. Cold injuries.

    Science.gov (United States)

    Kruse, R J

    1995-01-01

    There are two categories of cold injury. The first is hypothermia, which is a systemic injury to cold, and the second is frostbite, which is a local injury. Throughout history, entire armies, from George Washington to the Germans on the Russian Front in World War II, have fallen prey to prolonged cold exposure. Cold injury is common and can occur in all seasons if ambient temperature is lower than the core body temperature. In the 1985 Boston Marathon, even though it was 76 degrees and sunny, there were 75 runners treated for hypothermia. In general, humans adapt poorly to cold exposure. Children are at particular risk because of their relatively greater surface area/body mass ratio, causing them to cool even more rapidly than adults. Because of this, the human's best defense against cold injury is to limit his/her exposure to cold and to dress appropriately. If cold injury has occurred and is mild, often simple passive rewarming such as dry blankets and a warm room are sufficient treatment.

  15. Interest of new fluids for optimizing cold sources

    International Nuclear Information System (INIS)

    Mascarello, Jean; Fleury, Jean.

    1975-01-01

    Some principles relating to energy production cycles are surveyed. The problems involved in steam condensation in conventional cycles and heat evacuation towards a cold source (river water, sea water, or air) are exposed. A solution to the problems is given by using a binary OH 2 -NH 3 cycle and, especially, a total freedom in site selection is gained thanks to the lack in water needs. From an economic point of view, the binary cycle power plant takes its place better than its steam cycled, dry air cooled, rival. It is a little more expensive than the conventional seaside solution but presents many advantages against the latter [fr

  16. Observations of a Cold Front at High Spatiotemporal Resolution Using an X-Band Phased Array Imaging Radar

    Directory of Open Access Journals (Sweden)

    Andrew Mahre

    2017-02-01

    Full Text Available While the vertical structure of cold fronts has been studied using various methods, previous research has shown that traditional methods of observing meteorological phenomena (such as pencil-beam radars in PPI/volumetric mode are not well-suited for resolving small-scale cold front phenomena, due to relatively low spatiotemporal resolution. Additionally, non-simultaneous elevation sampling within a vertical cross-section can lead to errors in analysis, as differential vertical advection cannot be distinguished from temporal evolution. In this study, a cold front from 19 September 2015 is analyzed using the Atmospheric Imaging Radar (AIR. The AIR transmits a 20-degree fan beam in elevation, and digital beamforming is used on receive to generate simultaneous receive beams. This mobile, X-band, phased-array radar offers temporal sampling on the order of 1 s (while in RHI mode, range sampling of 30 m (37.5 m native resolution, and continuous, arbitrarily oversampled data in the vertical dimension. Here, 0.5-degree sampling is used in elevation (1-degree native resolution. This study is the first in which a cold front has been studied via imaging radar. The ability of the AIR to obtain simultaneous RHIs at high temporal sampling rates without mechanical steering allows for analysis of features such as Kelvin-Helmholtz instabilities and feeder flow.

  17. Large outbreak caused by methicillin resistant Staphylococcus pseudintermedius ST71 in a Finnish Veterinary Teaching Hospital--from outbreak control to outbreak prevention.

    Directory of Open Access Journals (Sweden)

    Thomas Grönthal

    Full Text Available INTRODUCTION: The purpose of this study was to describe a nosocomial outbreak caused by methicillin resistant Staphylococcus pseudintermedius (MRSP ST71 SCCmec II-III in dogs and cats at the Veterinary Teaching Hospital of the University of Helsinki in November 2010 - January 2012, and to determine the risk factors for acquiring MRSP. In addition, measures to control the outbreak and current policy for MRSP prevention are presented. METHODS: Data of patients were collected from the hospital patient record software. MRSP surveillance data were acquired from the laboratory information system. Risk factors for MRSP acquisition were analyzed from 55 cases and 213 controls using multivariable logistic regression in a case-control study design. Forty-seven MRSP isolates were analyzed by pulsed field gel electrophoresis and three were further analyzed with multi-locus sequence and SCCmec typing. RESULTS: Sixty-three MRSP cases were identified, including 27 infections. MRSPs from the cases shared a specific multi-drug resistant antibiogram and PFGE-pattern indicated clonal spread. Four risk factors were identified; skin lesion (OR = 6.2; CI95% 2.3-17.0, P = 0.0003, antimicrobial treatment (OR = 3.8, CI95% 1.0-13.9, P = 0.0442, cumulative number of days in the intensive care unit (OR = 1.3, CI95% 1.1-1.6, P = 0.0007 or in the surgery ward (OR = 1.1, CI95% 1.0-1.3, P = 0.0401. Tracing and screening of contact patients, enhanced hand hygiene, cohorting and barrier nursing, as well as cleaning and disinfection were used to control the outbreak. To avoid future outbreaks and spread of MRSP a search-and-isolate policy was implemented. Currently nearly all new MRSP findings are detected in screening targeted to risk patients on admission. CONCLUSION: Multidrug resistant MRSP is capable of causing a large outbreak difficult to control. Skin lesions, antimicrobial treatment and prolonged hospital stay increase the probability of acquiring MRSP. Rigorous control

  18. Regional Differences in Pathogen Prevalence and Defensive Reactions to the “Swine Flu” Outbreak among East Asians and Westerners

    Directory of Open Access Journals (Sweden)

    Takeshi Hamamura

    2010-07-01

    Full Text Available Research has found that contagion-minimizing behavioral tendencies are amplified in pathogen-prevalent regions. We investigated whether reactions to the “swine flu” outbreak of 2009 were stronger among East Asians than Westerners, populations residing in regions that now enjoy comparable advances in healthcare but that are characterized by relatively high and low historical pathogen prevalence, respectively. In a survey, East Asians reported greater concerns about infection, especially from foreigners. Analyses of international air travel data around the time of the outbreak provided corroborating evidence: Immediately following the outbreak, airports in the Asia-Pacific region lost more international traffic relative to their Western counterparts, and East Asian airlines reported greater declines in international traffic compared to Western airlines. These differences are unlikely to reflect objective threat posed by swine flu (whose casualties were concentrated in the Americas; rather, they appear to reflect culturally adapted behavioral patterns forged and sustained by regionally variable levels of pathogen prevalence.

  19. Dynamical Influence and Operational Impacts of an Extreme Mediterranean Cold Surge

    Science.gov (United States)

    2013-06-01

    in significant flooding over regions surrounding the Mediterranean Sea ( Trigo , Bigg, & Davies 2002). The cold air mass and associated cyclogenesis...119, 17–55. Trigo , I., G. Bigg, and T. Davies, 2002: Climatology of cyclogenesis mechanisms in the Mediterranean. Mon. Wea. Rev., 130, 549–569

  20. A hospital outbreak of Legionella from a contaminated water supply.

    Science.gov (United States)

    Tercelj-Zorman, Marjeta; Seljak, Marija; Stare, Janez; Mencinger, Joze; Rakovec, Joze; Rylander, Ragnar; Strle, Franc

    2004-03-01

    The authors performed a cross-sectional epidemiological survey to investigate the source of a hospital Legionella outbreak originating in contaminated water. Water temperature and air humidity were measured around possible contamination sources. A dead-end pipe was found to contain Legionella pneumophila serogroup 1. All individuals who acquired legionellosis had spent at least 30 min within 2 m of the contamination source. Among staff, 41 of 71 were exposed, and 31 of these fell ill. All 7 patients exposed to the contaminated water acquired legionellosis. None of the 94 bed-ridden patients from the same units developed the disease. An aerosol with 60% relative air humidity was formed near the suspect water faucets, but the humidity fell rapidly farther from the water source, suggesting that desiccation decreased the risk of infection. The healthy personnel and patients closest to the source acquired legionellosis, suggesting that risk was related less to compromised patients than to exposure.

  1. Designing and implementing an electronic dashboard for disease outbreaks response - Case study of the 2013-2014 Somalia Polio outbreak response dashboard.

    Science.gov (United States)

    Kamadjeu, Raoul; Gathenji, Caroline

    2017-01-01

    In April 2013, a case of wild polio virus (WPV) was detected in the Somalia capital Mogadishu. This inaugurated what is now referred to as the 2013-2014 Horn of Africa Polio outbreak with cases reported in Somalia, Kenya and Ethiopia. By the notification of the last polio case in August 2014, 223 cases of WPV had been reported in Somalia, Kenya and Ethiopia of which 199 in Somalia alone. The outbreak response required timely exchange of information between the outbreak response coordination unit (in Nairobi) and local staff located in multiple locations inside the country. The need to track and timely respond to information requests, to satisfy the information/data needs of polio partners and to track key outbreak response performance indicators dictated the need to urgently set up an online dashboard. The Somalia Polio Room dashboard provided a graphical display of the polio outbreak data to track progress and inform decision making. The system was designed using free and open sources components and seamlessly integrated existing polio surveillance data for real time monitoring of key outbreak response performance indicators. In this article, we describe the design and operation of an electronic dashboard for disease surveillance in an outbreak situation and used the lessons learned to propose key design considerations and functional requirements for online electronic dashboards for disease outbreak response.

  2. Faster Detection of Poliomyelitis Outbreaks to Support Polio Eradication.

    Science.gov (United States)

    Blake, Isobel M; Chenoweth, Paul; Okayasu, Hiro; Donnelly, Christl A; Aylward, R Bruce; Grassly, Nicholas C

    2016-03-01

    As the global eradication of poliomyelitis approaches the final stages, prompt detection of new outbreaks is critical to enable a fast and effective outbreak response. Surveillance relies on reporting of acute flaccid paralysis (AFP) cases and laboratory confirmation through isolation of poliovirus from stool. However, delayed sample collection and testing can delay outbreak detection. We investigated whether weekly testing for clusters of AFP by location and time, using the Kulldorff scan statistic, could provide an early warning for outbreaks in 20 countries. A mixed-effects regression model was used to predict background rates of nonpolio AFP at the district level. In Tajikistan and Congo, testing for AFP clusters would have resulted in an outbreak warning 39 and 11 days, respectively, before official confirmation of large outbreaks. This method has relatively high specificity and could be integrated into the current polio information system to support rapid outbreak response activities.

  3. Outbreaks Associated with Treated Recreational Water - United States, 2000-2014.

    Science.gov (United States)

    Hlavsa, Michele C; Cikesh, Bryanna L; Roberts, Virginia A; Kahler, Amy M; Vigar, Marissa; Hilborn, Elizabeth D; Wade, Timothy J; Roellig, Dawn M; Murphy, Jennifer L; Xiao, Lihua; Yates, Kirsten M; Kunz, Jasen M; Arduino, Matthew J; Reddy, Sujan C; Fullerton, Kathleen E; Cooley, Laura A; Beach, Michael J; Hill, Vincent R; Yoder, Jonathan S

    2018-05-18

    Outbreaks associated with exposure to treated recreational water can be caused by pathogens or chemicals in venues such as pools, hot tubs/spas, and interactive water play venues (i.e., water playgrounds). During 2000-2014, public health officials from 46 states and Puerto Rico reported 493 outbreaks associated with treated recreational water. These outbreaks resulted in at least 27,219 cases and eight deaths. Among the 363 outbreaks with a confirmed infectious etiology, 212 (58%) were caused by Cryptosporidium (which causes predominantly gastrointestinal illness), 57 (16%) by Legionella (which causes Legionnaires' disease, a severe pneumonia, and Pontiac fever, a milder illness with flu-like symptoms), and 47 (13%) by Pseudomonas (which causes folliculitis ["hot tub rash"] and otitis externa ["swimmers' ear"]). Investigations of the 363 outbreaks identified 24,453 cases; 21,766 (89%) were caused by Cryptosporidium, 920 (4%) by Pseudomonas, and 624 (3%) by Legionella. At least six of the eight reported deaths occurred in persons affected by outbreaks caused by Legionella. Hotels were the leading setting, associated with 157 (32%) of the 493 outbreaks. Overall, the outbreaks had a bimodal temporal distribution: 275 (56%) outbreaks started during June-August and 46 (9%) in March. Assessment of trends in the annual counts of outbreaks caused by Cryptosporidium, Legionella, or Pseudomonas indicate mixed progress in preventing transmission. Pathogens able to evade chlorine inactivation have become leading outbreak etiologies. The consequent outbreak and case counts and mortality underscore the utility of CDC's Model Aquatic Health Code (https://www.cdc.gov/mahc) to prevent outbreaks associated with treated recreational water.

  4. [Waterborne diseases outbreaks in the Czech Republic, 1995-2005].

    Science.gov (United States)

    Kozísek, F; Jeligová, H; Dvoráková, A

    2009-08-01

    Despite considerable advances in drinking water safety assurance and adherence to the public health standards, waterborne diaseases outbreaks have still been observed even in industrialized countries. The study objective was to map such outbreaks in the Czech Republic in 1995-2005. In this study, an outbreak is the occurrence of more cases of disease than normally expected within a specific place over a given period of time and a waterborne disease is a disease where water is the vehicle or source of infection. The data on waterborne outbreaks was obtained from the EPIDAT database (national infectious diseases reporting system) information provided by epidemiologists of all regional public health authorities and the National Reference Laboratory for Legionella. In 1995 - 2005, 33 outbreaks with water indicated as the route of transmission were recorded in the Czech Republic. The leading cause was unsafe drinking water (27 outbreaks), mainly from wells (19 outbreaks); nevertheless, the most serious consequences were observed in two outbreaks caused by microbiologically contaminated hot water. Other sources of waterborne infection were mineral water springs, a swimming pool and a brook. The total of reported cases of waterborne diseases was 1655, 356 hospitalisations and ten deaths due to legionellosis were recorded. The highest number of outbreaks (7) as well as the highest number of cases (841) were reported in 1997. Comparison of two five-year periods, i.e. 1996-2000 and 2001-2005, showed a nearly one third decrease in the total of outbreaks and a half reduction in the total of cases in the latter. In view of the limited length of monitoring, it is not possible to say with certainty whether it is a random distribution or an actual trend. Almost two thirds of cases were diagnosed as acute gastroenteritis of probable infectious origin and other frequent waterborne diseases were viral hepatitis A and bacillary dysentery. When analyzing the described outbreaks, it

  5. Analysis of Direct Outdoor Air Cooling Efficency for Combined Variable Air Volume Air-conditioning System in Stores in Cold Climates of China

    OpenAIRE

    Luo, Zhiwen

    2006-01-01

    Direct outdoor air cooling contributes a lot not only to the improvement of the indoor air quality but also to the energy saving. Its full use will reduce the water chiller’s running time especially in some stores where cooling load keeps much higher and longer than that in other buildings. A novel air-conditioning system named Combined Variable Air Volume system (CVAV), combining a normal AHU with a separate outdoor air supply system, was proposed firstly by the authors. The most attractive ...

  6. Air condensation plants

    International Nuclear Information System (INIS)

    Kelp, F.; Pohl, H.H.

    1978-01-01

    In this plant the steam is distributed by a ventilator from the bottom to symmetrically fixed, inclined cooling elements with tubes. The upper part of the current side of the cooling elements as well as the bottom part of the outflow side can be covered by cover plates via a control circuit. This way, part of the air amount is deviated and in case of unfavourable atmospheric conditions (cold) the air is heated. This heating is enough to prevent freezing of the condensate on the cooling tubes. (DG) [de

  7. Energetics of sows and gilts in gestation crates in the cold.

    NARCIS (Netherlands)

    Verstegen, M.W.A.; Curtis, S.E.

    1988-01-01

    Seventy pregnant sows and gilts in gestation crates with unbedded concrete-slat floors and partitions in common (which permitted contact by neighbors) in a closed house with air temperature 10 to 12 degrees C during cold weather were studied for 3 wk. The animals' lower critical temperature and

  8. Large Outbreak Caused by Methicillin Resistant Staphylococcus pseudintermedius ST71 in a Finnish Veterinary Teaching Hospital – From Outbreak Control to Outbreak Prevention

    Science.gov (United States)

    Grönthal, Thomas; Moodley, Arshnee; Nykäsenoja, Suvi; Junnila, Jouni; Guardabassi, Luca; Thomson, Katariina; Rantala, Merja

    2014-01-01

    Introduction The purpose of this study was to describe a nosocomial outbreak caused by methicillin resistant Staphylococcus pseudintermedius (MRSP) ST71 SCCmec II-III in dogs and cats at the Veterinary Teaching Hospital of the University of Helsinki in November 2010 – January 2012, and to determine the risk factors for acquiring MRSP. In addition, measures to control the outbreak and current policy for MRSP prevention are presented. Methods Data of patients were collected from the hospital patient record software. MRSP surveillance data were acquired from the laboratory information system. Risk factors for MRSP acquisition were analyzed from 55 cases and 213 controls using multivariable logistic regression in a case-control study design. Forty-seven MRSP isolates were analyzed by pulsed field gel electrophoresis and three were further analyzed with multi-locus sequence and SCCmec typing. Results Sixty-three MRSP cases were identified, including 27 infections. MRSPs from the cases shared a specific multi-drug resistant antibiogram and PFGE-pattern indicated clonal spread. Four risk factors were identified; skin lesion (OR = 6.2; CI95% 2.3–17.0, P = 0.0003), antimicrobial treatment (OR = 3.8, CI95% 1.0–13.9, P = 0.0442), cumulative number of days in the intensive care unit (OR = 1.3, CI95% 1.1–1.6, P = 0.0007) or in the surgery ward (OR = 1.1, CI95% 1.0–1.3, P = 0.0401). Tracing and screening of contact patients, enhanced hand hygiene, cohorting and barrier nursing, as well as cleaning and disinfection were used to control the outbreak. To avoid future outbreaks and spread of MRSP a search-and-isolate policy was implemented. Currently nearly all new MRSP findings are detected in screening targeted to risk patients on admission. Conclusion Multidrug resistant MRSP is capable of causing a large outbreak difficult to control. Skin lesions, antimicrobial treatment and prolonged hospital stay increase the probability of acquiring

  9. Atmospheric Infrared Sounder on NASA's Aqua Satellite: Applications for Volcano Rapid Response, Influenza Outbreak Prediction, and Drought Onset Prediction

    Science.gov (United States)

    Ray, S. E.; Fetzer, E. J.; Lambrigtsen, B.; Olsen, E. T.; Licata, S. J.; Hall, J. R.; Penteado, P. F.; Realmuto, V. J.; Thrastarson, H. T.; Teixeira, J.; Granger, S. L.; Behrangi, A.; Farahmand, A.

    2017-12-01

    The Atmospheric Infrared Sounder (AIRS) has been returning daily global observations of Earth's atmospheric constituents and properties since 2002. With its 15-year data record and near real-time capability, AIRS data are being used in the development of applications that fall within many of the NASA Applied Science focus areas. An automated alert system for volcanic plumes has been developed that triggers on threshold breaches of SO2, ash and dust in granules of AIRS data. The system generates a suite of granule-scale maps that depict both plume and clouds, all accessible from the AIRS web site. Alerts are sent to a curated list of volcano community members, and links to views in NASA Worldview and Google Earth are also available. Seasonal influenza epidemics are major public health concern with millions of cases of severe illness and large economic impact. Recent studies have highlighted the role of absolute or specific humidity as a likely player in the seasonal nature of these outbreaks. A quasi-operational influenza outbreak prediction system has been developed based on the SIRS model which uses AIRS and NCEP humidity data, Center for Disease Control reports on flu and flu-like illnesses, and results from Google Flu Trends. Work is underway to account for diffusion (spatial) in addition to the temporal spreading of influenza. The US Drought Monitor (USDM) is generated weekly by the National Drought Mitigation Center (NDMC) and is used by policymakers for drought decision-making. AIRS data have demonstrated utility in monitoring the development and detection of meteorological drought with both AIRS-derived standardized vapor pressure deficit and standardized relative humidity, showing early detection lead times of up to two months. An agreement was secured with the NDMC to begin a trial period using AIRS products in the production of the USDM, and in July of 2017 the operational delivery of weekly CONUS AIRS images of Relative Humidity, Surface Air Temperature

  10. Molecular Diagnostic Analysis of Outbreak Scenarios

    Science.gov (United States)

    Morsink, M. C.; Dekter, H. E.; Dirks-Mulder, A.; van Leeuwen, W. B.

    2012-01-01

    In the current laboratory assignment, technical aspects of the polymerase chain reaction (PCR) are integrated in the context of six different bacterial outbreak scenarios. The "Enterobacterial Repetitive Intergenic Consensus Sequence" (ERIC) PCR was used to analyze different outbreak scenarios. First, groups of 2-4 students determined optimal…

  11. Modeling and roles of meteorological factors in outbreaks of highly pathogenic avian influenza H5N1.

    Directory of Open Access Journals (Sweden)

    Paritosh K Biswas

    Full Text Available The highly pathogenic avian influenza A virus subtype H5N1 (HPAI H5N1 is a deadly zoonotic pathogen. Its persistence in poultry in several countries is a potential threat: a mutant or genetically reassorted progenitor might cause a human pandemic. Its world-wide eradication from poultry is important to protect public health. The global trend of outbreaks of influenza attributable to HPAI H5N1 shows a clear seasonality. Meteorological factors might be associated with such trend but have not been studied. For the first time, we analyze the role of meteorological factors in the occurrences of HPAI outbreaks in Bangladesh. We employed autoregressive integrated moving average (ARIMA and multiplicative seasonal autoregressive integrated moving average (SARIMA to assess the roles of different meteorological factors in outbreaks of HPAI. Outbreaks were modeled best when multiplicative seasonality was incorporated. Incorporation of any meteorological variable(s as inputs did not improve the performance of any multivariable models, but relative humidity (RH was a significant covariate in several ARIMA and SARIMA models with different autoregressive and moving average orders. The variable cloud cover was also a significant covariate in two SARIMA models, but air temperature along with RH might be a predictor when moving average (MA order at lag 1 month is considered.

  12. Outbreak of ocular toxoplasmosis in Coimbatore, India

    Directory of Open Access Journals (Sweden)

    Palanisamy Manikandan

    2006-01-01

    Full Text Available Toxoplasma gondii is a protozoan parasite that infects up to a third of the world′s population. Infection is mainly acquired by ingestion of food that is contaminated with oocysts. We report an outbreak of ocular toxoplasmosis, which is an acute acquired type rather than reactivation of congenital toxoplasmosis. Our preliminary investigation points to municipal water contamination. This outbreak only proves the need of an effective public health system and health education in curtailing any outbreak.

  13. Applications Using AIRS Data

    Science.gov (United States)

    Ray, S. E.; Pagano, T. S.; Fetzer, E. J.; Lambrigtsen, B.; Olsen, E. T.; Teixeira, J.; Licata, S. J.; Hall, J. R.; Thompson, C. K.

    2015-12-01

    The Atmospheric Infrared Sounder (AIRS) on NASA's Aqua spacecraft has been returning daily global observations of Earth's atmospheric constituents and properties since 2002. With a 12-year data record and daily, global observations in near real-time, AIRS data can play a role in applications that fall under many of the NASA Applied Sciences focus areas. For vector-borne disease, research is underway using AIRS near surface retrievals to assess outbreak risk, mosquito incubation periods and epidemic potential for dengue fever, malaria, and West Nile virus. For drought applications, AIRS temperature and humidity data are being used in the development of new drought indicators and improvement in the understanding of drought development. For volcanic hazards, new algorithms using AIRS data are in development to improve the reporting of sulfur dioxide concentration, the burden and height of volcanic ash and dust, all of which pose a safety threat to aircraft. In addition, anomaly maps of many of AIRS standard products are being produced to help highlight "hot spots" and illustrate trends. To distribute it's applications imagery, AIRS is leveraging existing NASA data frameworks and organizations to facilitate archiving, distribution and participation in the BEDI. This poster will communicate the status of the applications effort for the AIRS Project and provide examples of new maps designed to best communicate the AIRS data.

  14. An analysis of solar assisted ground source heat pumps in cold climates

    International Nuclear Information System (INIS)

    Emmi, Giuseppe; Zarrella, Angelo; De Carli, Michele; Galgaro, Antonio

    2015-01-01

    Highlights: • The work focuses on solar assisted ground source heat pump in cold climates. • Multi-year simulations of SAGSHP, are carried out in six cold locations. • GSHP and SAGSHP are compared. • The effect of total borehole length on the heat pump energy efficiency is studied. • A dedicated control strategy is used to manage both solar and ground loops. - Abstract: Exploiting renewable energy sources for air-conditioning has been extensively investigated over recent years, and many countries have been working to promote the use of renewable energy to decrease energy consumption and CO_2 emissions. Electrical heat pumps currently represent the most promising technology to reduce fossil fuel usage. While ground source heat pumps, which use free heat sources, have been taking significant steps forward and despite the fact that their energy performance is better than that of air source heat pumps, their development has been limited by their high initial investment cost. An alternative solution is one that uses solar thermal collectors coupled with a ground source heat pump in a so-called solar assisted ground source heat pump. A ground source heat pump system, used to heat environments located in a cold climate, was investigated in this study. The solar assisted ground source heat pump extracted heat from the ground by means of borehole heat exchangers and it injected excess solar thermal energy into the ground. Building load profiles are usually heating dominated in cold climates, but when common ground source heat pump systems are used only for heating, their performance decreases due to an unbalanced ground load. Solar thermal collectors can help to ensure that systems installed in cold zones perform more efficiently. Computer simulations using a Transient System Simulation (TRNSYS) tool were carried out in six cold locations in order to investigate solar assisted ground source heat pumps. The effect of the borehole length on the energy efficiency of

  15. Numerical Modeling of the Severe Cold Weather Event over Central Europe (January 2006

    Directory of Open Access Journals (Sweden)

    D. Hari Prasad

    2010-01-01

    Full Text Available Cold waves commonly occur in higher latitudes under prevailing high pressure systems especially during winter season which cause serious economical loss and cold related death. Accurate prediction of such severe weather events is important for decision making by administrators and for mitigation planning. An Advanced high resolution Weather Research and Forecasting mesoscale model is used to simulate a severe cold wave event occurred during January 2006 over Europe. The model is integrated for 31 days starting from 00UTC of 1 January 2006 with 30 km horizontal resolution. Comparison of the model derived area averaged daily mean temperatures at 2m height from different zones over the central Europe with observations indicates that the model is able to simulate the occurrence of the cold wave with the observed time lag of 1 to 3days but with lesser intensity. The temperature, winds, surface pressure and the geopential heights at 500 hPa reveal that the cold wave development associates with the southward progression of a high pressure system and cold air advection. The results have good agreement with the analysis fields indicates that the model has the ability to reproduce the time evolution of the cold wave event.

  16. MRSA outbreak at a transplantation unit

    Directory of Open Access Journals (Sweden)

    RMC Romanelli

    Full Text Available Methicillin-resistant Staphylococcus aureus (MRSA infections frequently complicate the post-operative course of transplant recipients, and despite nasal carriage and endemic colonization, MRSA outbreaks are not commonly described. This study reports a case of MRSA outbreak and discusses infection control measures and recommendations for this situation.

  17. Cold plate

    Energy Technology Data Exchange (ETDEWEB)

    Marroquin, Christopher M.; O' Connell, Kevin M.; Schultz, Mark D.; Tian, Shurong

    2018-02-13

    A cold plate, an electronic assembly including a cold plate, and a method for forming a cold plate are provided. The cold plate includes an interface plate and an opposing plate that form a plenum. The cold plate includes a plurality of active areas arranged for alignment over respective heat generating portions of an electronic assembly, and non-active areas between the active areas. A cooling fluid flows through the plenum. The plenum, at the non-active areas, has a reduced width and/or reduced height relative to the plenum at the active areas. The reduced width and/or height of the plenum, and exterior dimensions of cold plate, at the non-active areas allow the non-active areas to flex to accommodate surface variations of the electronics assembly. The reduced width and/or height non-active areas can be specifically shaped to fit between physical features of the electronics assembly.

  18. Investigating Listeria Outbreaks

    Centers for Disease Control (CDC) Podcasts

    Dr. Emily Cartwright, Infectious Disease fellow at Emory University and former EIS Officer with CDC’s Division of Foodborne, Waterborne, and Environmental Diseases discusses foodborne Listeria outbreaks.

  19. Interaction of cold radiofrequency plasma with seeds of beans (Phaseolus vulgaris)

    Science.gov (United States)

    Bormashenko, Edward; Shapira, Yekaterina; Grynyov, Roman; Whyman, Gene; Bormashenko, Yelena; Drori, Elyashiv

    2015-01-01

    The impact of cold radiofrequency air plasma on the wetting properties and water imbibition of beans (Phaseolus vulgaris) was studied. The influence of plasma on wetting of a cotyledon and seed coat (testa) was elucidated. It was established that cold plasma treatment leads to hydrophilization of the cotyledon and tissues constituting the testa when they are separately exposed to plasma. By contrast, when the entire bean is exposed to plasma treatment, only the external surface of the bean is hydrophilized by the cold plasma. Water imbibition by plasma-treated beans was studied. Plasma treatment markedly accelerates the water absorption. The crucial role of a micropyle in the process of water imbibition was established. It was established that the final percentage of germination was almost the same in the cases of plasma-treated, untreated, and vacuum-pumped samples. However, the speed of germination was markedly higher for the plasma-treated samples. The influence of the vacuum pumping involved in the cold plasma treatment on the germination was also clarified. PMID:25948708

  20. Air change. Ventilation requirements of closed rooms

    Energy Technology Data Exchange (ETDEWEB)

    Cords, W

    1988-04-01

    Closed rooms have to be ventilated in order to compensate influences changing the composition and quality of air. Details are given on the conditions and factors determining the required change of air as well as the design of ventilation systems. Reference is made to the respiratory consumption of oxygen, the increase of hazardous carbon dioxide contents causing headaches and indispositions, water vapor exhalations, body heat, odors, cold air coming in from outside, bodily heat losses, carbon dioxide limiting values, air speeds, and air pressures inside rooms. The humidity and temperatures of frequented rooms should keep within the maximum values. (HWJ).

  1. IEA HPT ANNEX 41 – Cold climate heat pumps: US country report

    Energy Technology Data Exchange (ETDEWEB)

    Groll, Eckhard A. [Purdue Univ., West Lafayette, IN (United States); Baxter, Van D. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2017-08-01

    In 2012 the International Energy Agency (IEA) Heat Pump Programme (now the Heat Pump Technologies (HPT) program) established Annex 41 to investigate technology solutions to improve performance of heat pumps for cold climates. Four IEA HPT member countries are participating in the Annex – Austria, Canada, Japan, and the United States (U.S.). The principal focus of Annex 41 is on electrically driven air-source heat pumps (ASHP) since that system type has the lowest installation cost of all heat pump alternatives. They also have the most significant performance challenges given their inherent efficiency and capacity issues at cold outdoor temperatures. Availability of ASHPs with improved low ambient performance would help bring about a much stronger heat pump market presence in cold areas, which today rely predominantly on fossil fuel furnace heating systems.

  2. Cold Start Emissions of Spark-Ignition Engines at Low Ambient Temperatures as an Air Quality Risk

    Directory of Open Access Journals (Sweden)

    Bielaczyc Piotr

    2014-12-01

    Full Text Available SI engines are highly susceptible to excess emissions when started at low ambient temperatures. This phenomenon has multiple air quality and climate forcing implications. Direct injection petrol engines feature a markedly different fuelling strategy, and so their emissions behaviour is somewhat different from indirect injection petrol engines. The excess emissions of direct injection engines at low ambient temperatures should also differ. Additionally, the direct injection fuel delivery process leads to the formation of PM, and DISI engines should show greater PM emissions at low ambient temperatures. This study reports on laboratory experiments quantifying excess emissions of gaseous and solid pollutants over a legislative driving cycle following cold start at a low ambient temperature for both engine types. Over the legislative cycle for testing at -7°C (the UDC, emissions of HC, CO, NOx and CO2 were higher when tested at -7°C than at 24°C. Massive increases in emissions of HC and CO were observed, together with more modest increases in NOx and CO2 emissions. Results from the entire driving cycle showed excess emissions in both phases (though they were much larger for the UDC. The DISI vehicle showed lower increases in fuel consumption than the port injected vehicles, but greater increases in emission of HC and CO. DISI particle number emissions increased by around 50%; DISI particle mass by over 600%. The observed emissions deteriorations varied somewhat by engine type and from vehicle to vehicle. Excesses were greatest following start-up, but persisted, even after several hundred seconds’ driving. The temperature of the intake air appeared to have a limited but significant effect on emissions after the engine has been running for some time. All vehicles tested here comfortably met the relevant EU limits, providing further evidence that these limits are no longer challenging and need updating.

  3. Systems for eliminating pathogens from exhaust air of animal houses

    NARCIS (Netherlands)

    Aarnink, A.J.A.; Landman, W.J.M.; Melse, R.W.; Huynh Thi Thanh Thuy,

    2005-01-01

    Recent outbreaks of highly infectious viral diseases like swine fever and avian influenza in The Netherlands have shown that despite extensive bio-security measures aiming at minimizing physical contacts between farms, disease spread could not be halted. Dust in exhaust air from swine and chicken

  4. Mitigating Infectious Disease Outbreaks

    Science.gov (United States)

    Davey, Victoria

    The emergence of new, transmissible infections poses a significant threat to human populations. As the 2009 novel influenza A/H1N1 pandemic and the 2014-2015 Ebola epidemic demonstrate, we have observed the effects of rapid spread of illness in non-immune populations and experienced disturbing uncertainty about future potential for human suffering and societal disruption. Clinical and epidemiologic characteristics of a newly emerged infectious organism are usually gathered in retrospect as the outbreak evolves and affects populations. Knowledge of potential effects of outbreaks and epidemics and most importantly, mitigation at community, regional, national and global levels is needed to inform policy that will prepare and protect people. Study of possible outcomes of evolving epidemics and application of mitigation strategies is not possible in observational or experimental research designs, but computational modeling allows conduct of `virtual' experiments. Results of well-designed computer simulations can aid in the selection and implementation of strategies that limit illness and death, and maintain systems of healthcare and other critical resources that are vital to public protection. Mitigating Infectious Disease Outbreaks.

  5. Liquid air fueled open–closed cycle Stirling engine

    International Nuclear Information System (INIS)

    Xu, Weiqing; Wang, Jia; Cai, Maolin; Shi, Yan

    2015-01-01

    Highlights: • Energy of liquid air is divided into cryogenic energy and expansion energy. • Open–closed cycle Stirling mechanism is employed to improve efficiency. • The Schmidt theory is modified to describe temperature variation in cold space. - Abstract: An unconventional Stirling engine is proposed and its theoretical analysis is performed. The engine belongs to a “cryogenic heat engine” that is fueled by cryogenic medium. Conventional “cryogenic heat engine” employs liquid air as pressure source, but disregards its heat-absorbing ability. Therefore, its efficiency can only be improved by increasing vapor pressure, accordingly increasing the demand on pressure resistance and sealing. In the proposed engine, the added Stirling mechanism helps achieve its high efficiency and simplicity by utilizing the heat-absorbing ability of liquid air. On one hand, based on Stirling mechanism, gas in the hot space absorbs heat from atmosphere when expanding; gas in the cold space is cooled down by liquid air when compressed. Taking atmosphere as heat source and liquid air as heat sink, a closed Stirling cycle is formed. On the other hand, an exhaust port is set in the hot space. When expanding in the hot space, the vaporized gas is discharged through the exhaust port. Thus, an open cycle is established. To model and analyze the system, the Schmidt theory is modified to describe temperature variation in the cold space, and irreversible characteristic of regenerator is incorporated in the thermodynamic model. The results obtained from the model show that under the same working pressure, the efficiency of the proposed engine is potentially higher than that of conventional ones and to achieve the same efficiency, the working pressure could be lower with the new mechanism. Its efficiency could be improved by reducing temperature difference between the regenerator and the cold/hot space, increasing the swept volume ratio, decreasing the liquid–gas ratio. To keep

  6. Outbreak or Epidemic? How Obama's Language Choice Transformed the Ebola Outbreak Into an Epidemic.

    Science.gov (United States)

    Gesser-Edelsburg, Anat; Shir-Raz, Yaffa; Bar-Lev, Oshrat Sassoni; James, James J; Green, Manfred S

    2016-08-01

    Our aim was to examine in what terms leading newspapers' online sites described the current Ebola crisis. We employed a quantitative content analysis of terms attributed to Ebola. We found and analyzed 582 articles published between March 23 and September 30, 2014, on the online websites of 3 newspapers: The New York Times, Daily Mail, and Ynet. Our theoretical framework drew from the fields of health communication and emerging infectious disease communication, including such concepts as framing media literacy, risk signatures, and mental models. We found that outbreak and epidemic were used interchangeably in the articles. From September 16, 2014, onward, epidemic predominated, corresponding to when President Barack Obama explicitly referred to Ebola as an epidemic. Prior to Obama's speech, 86.8% of the articles (323) used the term outbreak and only 8.6% (32) used the term epidemic. Subsequently, both terms were used almost the same amount: 53.8% of the articles (113) used the term outbreak and 53.3% (112) used the term epidemic. Effective communication is crucial during public health emergencies such as Ebola, because language framing affects the decision-making process of social judgments and actions. The choice of one term (outbreak) over another (epidemic) can create different conceptualizations of the disease, thereby influencing the risk signature. (Disaster Med Public Health Preparedness. 2016;10:669-673).

  7. Infection control during filoviral hemorrhagic fever outbreaks

    Directory of Open Access Journals (Sweden)

    N Raabe Vanessa

    2012-01-01

    Full Text Available Breaking the human-to-human transmission cycle remains the cornerstone of infection control during filoviral (Ebola and Marburg hemorrhagic fever outbreaks. This requires effective identification and isolation of cases, timely contact tracing and monitoring, proper usage of barrier personal protection gear by health workers, and safely conducted burials. Solely implementing these measures is insufficient for infection control; control efforts must be culturally sensitive and conducted in a transparent manner to promote the necessary trust between the community and infection control team in order to succeed. This article provides a review of the literature on infection control during filoviral hemorrhagic fever outbreaks focusing on outbreaks in a developing setting and lessons learned from previous outbreaks. The primary search database used to review the literature was PUBMED, the National Library of Medicine website.

  8. Cold flow model study of an oxyfuel combustion pilot plant

    Energy Technology Data Exchange (ETDEWEB)

    Guio-Perez, D.C.; Tondl, G.; Hoeltl, W.; Proell, T.; Hofbauer, H. [Vienna University of Technology, Institute of Chemical Engineering, Vienna (Austria)

    2011-12-15

    The fluid-dynamic behavior of a circulating fluidized bed pilot plant for oxyfuel combustion was studied in a cold flow model, down-scaled using Glicksman's criteria. Pressures along the unit and the global circulation rate were used for characterization. The analysis of five operating parameters and their influence on the system was carried out; namely, total solids inventory and the air velocity of primary, secondary, loop seal and support fluidizations. The cold flow model study shows that the reactor design allows stable operation at a wide range of fluidization rates, with results that agree well with previous observations described in the literature. (Copyright copyright 2011 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  9. Conceptual design of HANARO cold neutron source

    International Nuclear Information System (INIS)

    Lee, Chang Hee; Sim, Cheul Muu; Park, K. N.; Choi, Y. H.

    2002-07-01

    The purpose of the cold source is to increase the available neutron flux delivered to instruments at wavelength 4 ∼ 12 A. The major engineering targets of this CNS facility is established for a reach out of very high gain factors in consideration with the cold neutron flux, moderator, circulation loop, heat load, a simplicity of the maintenance of the facility, safety in the operation of the facility against the hydrogen explosion and a layout of a minimum physical interference with the present facilities. The cold source project has been divided into 5 phases: (1) pre-conceptual (2) conceptual design (3) Testing (4) detailed design and procurement (5) installation and operation. Although there is sometime overlap between the phases, in general, they are sequential. The pre-conceptual design and concept design of KCNS has been performed on elaborations of PNPI Russia and review by Technicatome, Air Liquid, CILAS France. In the design of cold neutron source, the characteristics of cold moderators have been studied to obtain the maximum gain of cold neutron, and the analysis for radiation heat, design of hydrogen system, vacuum system and helium system have been performed. The possibility for materialization of the concept in the proposed conceptual design has been reviewed in view of securing safety and installing at HANARO. Above all, the thermosiphon system to remove heat by circulation of sub-cooled two phase hydrogen has been selected so that the whole device could be installed in the reactor pool with the reduced volume. In order to secure safety, hydrogen safety has been considered on protection to prevent from hydrogen-oxygen reaction at explosion of hydrogen-oxygen e in the containment. A lay out of the installation, a maintenance and quality assurance program and a localization are included in this report. Requirements of user, regulatory, safety, operation, maintenance should be considered to be revised for detailed design, testing, installation

  10. Draught control by means of industrial air curtains. Background information on the design of industrial air curtains; Tochtbestrijding met industriele luchtgordijnen. Achtergronden bij ontwerp van industriele luchtgrodijnen

    Energy Technology Data Exchange (ETDEWEB)

    Cremers, B. [Biddle, Kootstertille (Netherlands); Traversar, R. [TNO Milieu, Energie en Procesinnovatie TNO-MEP, Apeldoorn (Netherlands)

    2008-02-15

    In industrial buildings a balanced ventilation is not common property. Due to increasing differences in pressure across the front much cold outside air enters the building, resulting in poor comfort near the door. A good air curtain can heat up large amounts of incoming cold outside air in such a way that energy saving is optimal and comfort remains high. (mk) [Dutch] Bij industriele gebouwen is gebalanceerde ventilatie geen gemeengoed. Door oplopende drukverschillen over de gevel komt veel koude buitenlucht naar binnen en is het comfort vlak achter de deur erg laag. Een goed luchtgordijn kan grote hoeveelheden binnenkomende koude buitenlucht zodanig opwarmen dat de energiebesparing optimaal is en het comfort hoog blijft.

  11. Conceptualizing Cold Disasters

    DEFF Research Database (Denmark)

    Lauta, Kristian Cedervall; Dahlberg, Rasmus; Vendelø, Morten Thanning

    2017-01-01

    In the present article, we explore in more depth the particular circumstances and characteristics of governing what we call ‘cold disasters’, and thereby, the paper sets out to investigate how disasters in cold contexts distinguish themselves from other disasters, and what the implications hereof...... are for the conceptualization and governance of cold disasters. Hence, the paper can also be viewed as a response to Alexander’s (2012a) recent call for new theory in the field of disaster risk reduction. The article is structured in four overall parts. The first part, Cold Context, provides an overview of the specific...... conditions in a cold context, exemplified by the Arctic, and zooms in on Greenland to provide more specific background for the paper. The second part, Disasters in Cold Contexts, discusses “cold disasters” in relation to disaster theory, in order to, elucidate how cold disasters challenge existing...

  12. A Classification System for Hospital-Based Infection Outbreaks

    Directory of Open Access Journals (Sweden)

    Paul S. Ganney

    2010-01-01

    Full Text Available Outbreaks of infection within semi-closed environments such as hospitals, whether inherent in the environment (such as Clostridium difficile (C.Diff or Methicillinresistant Staphylococcus aureus (MRSA or imported from the wider community (such as Norwalk-like viruses (NLVs, are difficult to manage. As part of our work on modelling such outbreaks, we have developed a classification system to describe the impact of a particular outbreak upon an organization. This classification system may then be used in comparing appropriate computer models to real outbreaks, as well as in comparing different real outbreaks in, for example, the comparison of differing management and containment techniques and strategies. Data from NLV outbreaks in the Hull and East Yorkshire Hospitals NHS Trust (the Trust over several previous years are analysed and classified, both for infection within staff (where the end of infection date may not be known and within patients (where it generally is known. A classification system consisting of seven elements is described, along with a goodness-of-fit method for comparing a new classification to previously known ones, for use in evaluating a simulation against history and thereby determining how ‘realistic’ (or otherwise it is.

  13. A classification system for hospital-based infection outbreaks.

    Science.gov (United States)

    Ganney, Paul S; Madeo, Maurice; Phillips, Roger

    2010-12-01

    Outbreaks of infection within semi-closed environments such as hospitals, whether inherent in the environment (such as Clostridium difficile (C.Diff) or Methicillin-resistant Staphylococcus aureus (MRSA) or imported from the wider community (such as Norwalk-like viruses (NLVs)), are difficult to manage. As part of our work on modelling such outbreaks, we have developed a classification system to describe the impact of a particular outbreak upon an organization. This classification system may then be used in comparing appropriate computer models to real outbreaks, as well as in comparing different real outbreaks in, for example, the comparison of differing management and containment techniques and strategies. Data from NLV outbreaks in the Hull and East Yorkshire Hospitals NHS Trust (the Trust) over several previous years are analysed and classified, both for infection within staff (where the end of infection date may not be known) and within patients (where it generally is known). A classification system consisting of seven elements is described, along with a goodness-of-fit method for comparing a new classification to previously known ones, for use in evaluating a simulation against history and thereby determining how 'realistic' (or otherwise) it is.

  14. Field measurements of moisture variation in cold ventilated attics with different ceiling constructions

    DEFF Research Database (Denmark)

    Hansen, Thor; Møller, Eva B.

    2017-01-01

    Adding insulation material on ceilings against cold ventilated attics is one of the most straightforward tasks of adding insulation. Theoretically, a higher amount of insulation in the attic decreases the temperature and consequently the capability of removing infiltrated indoor humid air. Field...

  15. Feasibility of a solar-assisted winter air-conditioning system using evaporative air-coolers

    Energy Technology Data Exchange (ETDEWEB)

    El-Awad, Mohamed M. [Mechanical Engineering Department, the University of Khartoum, P.O. Box 321 Khartoum (Sudan)

    2011-07-01

    The paper presents a winter air-conditioning system which is suitable for regions with mildly cold but dry winters. The system modifies the evaporative air-cooler that is commonly used for summer air-conditioning in such regions by adding a heating process after the humidification process. The paper describes a theoretical model that is used to estimate the system's water and energy consumption. It is shown that a 150-LPD solar heater is adequate for air-conditioning a 500 ft3/min (14.4 m3/min) air flow rate for four hours of operation. The maximum air-flow rate that can be heated by a single solar water-heater for four hours of operation is about 900-cfm, unless a solar water heater large than a 250-LPD heater is used. For the 500 ft3/min air flow rate the paper shows that the 150, 200, 250 and 300 LPD solar water-heaters can provide air-conditioning for 4, 6, 8 and 10 hours, respectively, while consuming less energy than the equivalent refrigerated-type air-conditioner.

  16. Measles & rubella outbreaks in Maharashtra State, India

    Science.gov (United States)

    Vaidya, Sunil R.; Kamble, Madhukar B.; Chowdhury, Deepika T.; Kumbhar, Neelakshi S.

    2016-01-01

    Background & objectives: Under the outbreak-based measles surveillance in Maharashtra State the National Institute of Virology at Pune receives 3-5 serum samples from each outbreak and samples from the local hospitals in Pune for laboratory diagnosis. This report describes one year data on the measles and rubella serology, virus isolation and genotyping. Methods: Maharashtra State Health Agencies investigated 98 suspected outbreaks between January-December 2013 in the 20 districts. Altogether, 491 serum samples were received from 20 districts and 126 suspected cases from local hospitals. Samples were tested for the measles and rubella IgM antibodies by commercial enzyme immunoassay (EIA). To understand the diagnostic utility, a subset of serum samples (n=53) was tested by measles focus reduction neutralization test (FRNT). Further, 37 throat swabs and 32 urine specimens were tested by measles reverse transcription (RT)-PCR and positive products were sequenced. Virus isolation was performed in Vero hSLAM cells. Results: Of the 98 suspected measles outbreaks, 61 were confirmed as measles, 12 as rubella and 21 confirmed as the mixed outbreaks. Four outbreaks remained unconfirmed. Of the 126 cases from the local hospitals, 91 were confirmed for measles and three for rubella. Overall, 93.6 per cent (383/409) confirmed measles cases were in the age group of 0-15 yr. Measles virus was detected in 18 of 38 specimens obtained from the suspected cases. Sequencing of PCR products revealed circulation of D4 (n=9) and D8 (n=9) strains. Four measles viruses (three D4 & one D8) were isolated. Interpretation & conclusions: Altogether, 94 measles and rubella outbreaks were confirmed in 2013 in the State of Maharasthra indicating the necessity to increase measles vaccine coverage in the State. PMID:27121521

  17. RNA-Seq-based analysis of the physiologic cold shock-induced changes in Moraxella catarrhalis gene expression.

    Directory of Open Access Journals (Sweden)

    Violeta Spaniol

    Full Text Available BACKGROUND: Moraxella catarrhalis, a major nasopharyngeal pathogen of the human respiratory tract, is exposed to rapid downshifts of environmental temperature when humans breathe cold air. The prevalence of pharyngeal colonization and respiratory tract infections caused by M. catarrhalis is greatest in winter. We investigated how M. catarrhalis uses the physiologic exposure to cold air to regulate pivotal survival systems that may contribute to M. catarrhalis virulence. RESULTS: In this study we used the RNA-seq techniques to quantitatively catalogue the transcriptome of M. catarrhalis exposed to a 26 °C cold shock or to continuous growth at 37 °C. Validation of RNA-seq data using quantitative RT-PCR analysis demonstrated the RNA-seq results to be highly reliable. We observed that a 26 °C cold shock induces the expression of genes that in other bacteria have been related to virulence a strong induction was observed for genes involved in high affinity phosphate transport and iron acquisition, indicating that M. catarrhalis makes a better use of both phosphate and iron resources after exposure to cold shock. We detected the induction of genes involved in nitrogen metabolism, as well as several outer membrane proteins, including ompA, m35-like porin and multidrug efflux pump (acrAB indicating that M. catarrhalis remodels its membrane components in response to downshift of temperature. Furthermore, we demonstrate that a 26 °C cold shock enhances the induction of genes encoding the type IV pili that are essential for natural transformation, and increases the genetic competence of M. catarrhalis, which may facilitate the rapid spread and acquisition of novel virulence-associated genes. CONCLUSION: Cold shock at a physiologically relevant temperature of 26 °C induces in M. catarrhalis a complex of adaptive mechanisms that could convey novel pathogenic functions and may contribute to enhanced colonization and virulence.

  18. Healthcare-associated outbreaks due to Mucorales and other uncommon fungi.

    Science.gov (United States)

    Davoudi, Setareh; Graviss, Linda S; Kontoyiannis, Dimitrios P

    2015-07-01

    Healthcare-associated outbreaks of fungal infections, especially with uncommon and emerging fungi, have become more frequent in the past decade. Here, we reviewed the history and definition of healthcare-associated outbreaks of uncommon fungal infections and discussed the principles of investigating, containing and treatment of these outbreaks. In case of these uncommon diseases, occurrence of two or more cases in a short period is considered as an outbreak. Contaminated medical devices and hospital environment are the major sources of these outbreaks. Care must be taken to differentiate a real infection from colonization or contamination. Defining and identifying cases, describing epidemiologic feature of cases, finding and controlling the source of the outbreak, treating patients, and managing asymptomatic exposed patients are main steps for outbreak elimination. These fungal outbreaks are not only difficult to detect but also hard to treat. Early initiation of appropriate antifungal therapy is strongly associated with improved outcomes in infected patients. Choice of antifungal drugs should be made based on spectrum, pharmacodynamic and pharmacokinetic characteristics and adverse effects of available drugs. Combination antifungal therapy and surgical intervention may be also helpful in selected cases. A multidisciplinary approach and close collaboration between all key partners are necessary for successful control of fungal outbreaks. © 2015 Stichting European Society for Clinical Investigation Journal Foundation.

  19. [Hospital hygiene - outbreak management of nosocomial infections].

    Science.gov (United States)

    Kerwat, Klaus; Wulf, Hinnerk

    2012-04-01

    According to §6, section 3 of the German Protection against Infections Act [Infektionsschutzgesetz (IfSG)] an outbreak is defined as the occurrence in large numbers of nosocomial infections for which an epidemiological relationship is probable or can be assumed. About 2-10% of nosocomial infections in hospitals (about 5% in intensive care wards) occur within the framework of an outbreak. The heaped occurrence of nosocomial infections can be declared according to the prescribed surveillance of nosocomial infections (§23 IfSG) when, in the course of this assessment, a statistically significant increase in the rate of infections becomes apparent. On the other hand, the occurrence of an outbreak can also be recognized through the vigilance of all involved personnel and a general sensibilization towards this subject. The names of patients involved in outbreaks need not be reported to the responsible health authorities. As a consequence of the report the health authorities become involved in the investigation to determine the cause and its elimination, and to provide support and advice. The outbreak management should be oriented on the respective recommendations of the Robert Koch Institute. © Georg Thieme Verlag Stuttgart · New York.

  20. Observations of Cold Pool Properties during GoAmazon2014/5

    Science.gov (United States)

    Mayne, S. L.; Schumacher, C.; MacDonald, L.; Turner, D. D.

    2017-12-01

    potential temperature and specific humidity profiles show promising similarities with theoretical results produced using the cold pool parameterization presented by Del Genio et al. (2015); however, results are sensitive to both the mass of air injected into the cold pool after its formation, and the thermodynamic characteristics of the downdraft.

  1. An outbreak of Salmonella gastroenteritis in an urban jail.

    Science.gov (United States)

    Alcabes, P; O'Sullivan, B; Nadal, E; Mouzon, M

    1988-12-01

    An outbreak of gastroenteritis in New York City's largest jail involved 145 cases over a two-month period. The outbreak was unusual in that two Salmonella strains (serogroups B and D) were involved. Management of the outbreak involved screening kitchen workers by culture of stool samples, and education regarding personal hygiene. Obstacles to investigation and management of the outbreak arose out of the special nature of the jail environment; these included jurisdictional problems and high turnover of the inmate population.

  2. A review of critical care nursing and disease outbreak preparedness.

    Science.gov (United States)

    Makamure, Miranda; Makamure, Muriel; Mendiola, Williane; Renteria, Daisy; Repp, Melissa; Willden, Azshwee

    2013-01-01

    The impact of disease outbreaks continues to increase globally. As frontline staff, critical care nurses (CCNs) are more likely to be confronted with the need to care for affected patients. With different pathological diseases emerging, CCNs play an integral role in disease outbreaks. The advanced skill set of CCNs is pivotal in the management and care of patients during an outbreak. Lack of planning and preparation before disease outbreaks leads to detrimental patient outcomes. Panic, chaos, and fear for personal safety cause stress and anxiety for unprepared nurses. However, this problem can be resolved. Comprehensive planning, training, and education can better prepare intensive care unit nurses for disease outbreaks. This article reviews some of the current literature on intensive care unit nurse preparedness for disease outbreaks in the United States. This article also offers strategies that may be used to better prepare CCNs for disease outbreaks.

  3. Cold stress increases reactive oxygen species formation via TRPA1 activation in A549 cells.

    Science.gov (United States)

    Sun, Wenwu; Wang, Zhonghua; Cao, Jianping; Cui, Haiyang; Ma, Zhuang

    2016-03-01

    Reactive oxygen species (ROS) are responsible for lung damage during inhalation of cold air. However, the mechanism of the ROS production induced by cold stress in the lung is still unclear. In this work, we measured the changes of ROS and the cytosolic Ca(2+) concentration ([Ca(2+)]c) in A549 cell. We observed that cold stress (from 20 to 5 °C) exposure of A549 cell resulted in an increase of ROS and [Ca(2+)]c, which was completely attenuated by removing Ca(2+) from medium. Further experiments showed that cold-sensing transient receptor potential subfamily member 1 (TRPA1) agonist (allyl isothiocyanate, AITC) increased the production of ROS and the level of [Ca(2+)]c in A549 cell. Moreover, HC-030031, a TRPA1 selective antagonist, significantly inhibited the enhanced ROS and [Ca(2+)]c induced by AITC or cold stimulation, respectively. Taken together, these data demonstrated that TRPA1 activation played an important role in the enhanced production of ROS induced by cold stress in A549 cell.

  4. Biology and outbreaks of Microdiprion pallipes (Hymenoptera; Diprionidae) in Sweden

    Energy Technology Data Exchange (ETDEWEB)

    Olofsson, E. (Swedish Univ. of Agricultural Sciences, Uppsala (Sweden). Dept. of Entomology)

    1994-01-01

    During outbreaks, Microdiprion pallipes (Fall.) is the most destructive of the pine sawflies in Sweden. Its distribution includes most provinces, but damaging outbreaks have until recently occurred only in two inland areas in northern Sweden. These areas are characterised by high elevation, a harsh climate, and slow tree growth. The four recorded outbreak periods showed a 10 year periodicity. Outside these areas, a lesser outbreak occurred in 1988 to 1990, on the east coast (province of Uppland). Outbreak patterns, life history variation, and mortality factors were studied. Factors that may explain the distribution of outbreaks and the population patterns were identified.Experimental and observational evidence on the potential of various factors to influence fecundity, dispersal, and survival was evaluated. In the outbreak areas, there were few major population factors. Parasitism by Rhorus substitutor (Thunb.) was the largest cause of larval mortality and the only important density-dependent mortality factor. The different diapause strategies of M. pallipes and R. substitutor may contribute to stabilize this system. Different flight periods of the host and the parasitoid may explain a possible correlation between weather and outbreaks. Elsewhere in Sweden, where low population densities prevail, there may be similarities in population processes between M. pallipes and the other widely distributed diprionids with solitary larvae, which never have attained outbreak densities in Sweden. Interactions with other diprionids through shared natural enemies may be an important population process and may influence the distribution of outbreaks. 37 refs, 4 figs, 11 tabs

  5. Defining Winter and Identifying Synoptic Air Mass Change in the Northeast and Northern Plains U.S. since 1950

    Science.gov (United States)

    Chapman, C. J.; Pennington, D.; Beitscher, M. R.; Godek, M. L.

    2017-12-01

    Understanding and forecasting the characteristics of winter weather change in the northern U.S. is vital to regional economy, agriculture, tourism and resident life. This is especially true in the Northeast and Northern Plains where substantial changes to the winter season have already been documented in the atmospheric science and biological literature. As there is no single established definition of `winter', this research attempts to identify the winter season in both regions utilizing a synoptic climatological approach with air mass frequencies. The Spatial Synoptic Classification is used to determine the daily air mass/ weather type conditions since 1950 at 40 locations across the two regions. Annual frequencies are first computed as a baseline reference. Then winter air mass frequencies and departures from normal are calculated to define the season along with the statistical significance. Once the synoptic winter is established, long-term regional changes to the season and significance are explored. As evident global changes have occurred after 1975, an Early period of years prior to 1975 and a Late set for all years following this date are compared. Early and Late record synoptic changes are then examined to assess any thermal and moisture condition changes of the regional winter air masses over time. Cold to moderately dry air masses dominate annually in both regions. Northeast winters are also characterized by cold to moderate dry air masses, with coastal locations experiencing more Moist Polar types. The Northern Plains winters are dominated by cold, dry air masses in the east and cold to moderate dry air masses in the west. Prior to 1975, Northeast winters are defined by an increase in cooler and wetter air masses. Dry Tropical air masses only occur in this region after 1975. Northern Plains winters are also characterized by more cold, dry air masses prior to 1975. More Dry Moderate and Moist Moderate air masses have occurred since 1975. These results

  6. A mixed outbreak of rubeola-rubella in district Kangra of Northern India

    Directory of Open Access Journals (Sweden)

    Surender N Gupta

    2013-01-01

    Full Text Available Background: On 14 th September 2006, a local community leader informed us about the sudden increase in number of cases of fever and rash in five villages of district Kangra. We investigated the suspected outbreak to confirm the diagnosis and recommend for prevention and control. Materials and Methods: We defined a case of rubeola as the occurrence of fever with rash in children from 3 rd September to 13 th January, 2007. We collected information on age, sex, date of onset, residence, signs, symptoms, vaccination and cold chain status. We described the outbreak by place, time and person characteristics. We conducted a retrospective cohort study to estimate vaccine efficacy (VE. We ascertained the measles immunization status by interviewing the mothers and reviewing immunization cards. We confirmed diagnosis clinically, epidemiologically and serologically. Results: We identified 60 case patients in five villages (41/60 rubeola and 11/60 confirmed epidemiologically linked unvaccinated rubella. The overall attack rate (AR was 9%. Sex specific AR was 11% for male. Majorities of cases were >5 years of age. No death/minimal complications have occurred. Of 60 case-patients, 42 (70% were vaccinated for rubeola. The AR of rubeola among unvaccinated children was 25.8% as compared to AR among vaccinated of 4.5% (relative risk: 5.75%; 95% confidence interval: 3.48-9.51 P < 0.001. We estimated general VE to be 83% while gender based VE for male was 84%. Eight case-patients were confirmed serologically for measles immunoglobin M antibodies, two nasopharyngeal swabs positive by polymerase chain reaction. Rubeola virus was genotyped D4. Only 30% (18/60 of the cases took the treatment from modern system of medicine. Conclusion: A mixed outbreak of rubeola/rubella was confirmed clinically, epidemiologically and serologically. We recommend measles and rubella (MR vaccination at the age of 18-24 months and aggressive Information, Education and Communication (IEC

  7. Management of Nosocomial Scabies, an Outbreak of Occupational Disease

    NARCIS (Netherlands)

    Jungbauer, Frank H. W.; Veenstra-Kyuchukova, Yanka K.; Koeze, Jacqueline; KruijtSpanjer, Martijn R.; Kardaun, Sylvia H.

    Background The optimal approach to managing institutional scabies outbreaks has yet to be defined. We report on outbreak managements are needed. Methods We report on a large outbreak of scabies in three acute care wards in a tertiary university teaching hospital in the Netherlands. Results The

  8. New Mixed Conductivity Mechanisms in the Cold Plasma Device Based on Silver-Modified Zeolite Microporous Electronic Materials

    Science.gov (United States)

    Koç, Sevgul Ozturk; Galioglu, Sezin; Ozturk, Seckin; Kurç, Burcu Akata; Koç, Emrah; Salamov, Bahtiyar G.

    2018-02-01

    We have analyzed the interaction between microdischarge and microporous zeolite electronic materials modified by silver (Ag0) nanoparticles (resistivity 1011 to 106 Ω cm) on the atmospheric pressure cold plasma generation in air. The generation and maintenance of stable cold plasma is studied according to the effect of the Ag0 nanoparticles. The role of charge carriers in mixed conductivity processes and electrical features of zeolite from low pressure to atmospheric pressure is analyzed in air microplasmas for both before and after breakdown regimes. The results obtained from the experiments indicate that Ag0 nanoparticles play a significant role in considerably reducing the breakdown voltage in plasma electronic devices with microporous zeolite electronic materials.

  9. Cold urticaria. Dissociation of cold-evoked histamine release and urticara following cold challenge.

    Science.gov (United States)

    Keahey, T M; Greaves, M W

    1980-02-01

    Nine patients with acquired cold urticaria were studied to assess the effects of beta-adrenergic agents, xanthines, and corticosteroids on cold-evoked histamine release from skin in vivo. The patients, in all of whom an immediate urticarial response developed after cooling of the forearm, demonstrated release of histamine into the venous blood draining that forearm. Following treatment with aminophylline and albuterol in combination or prednisone alone, suppression of histamine release occurred in all but one patient. In some patients, this was accompanied by a subjective diminution in pruritus or buring, but there was no significant improvement in the ensuing edema or erythema. In one patient, total suppression of histamine release was achieved without any effect on whealing and erythema in response to cold challenge. Our results suggest that histamine is not central to the pathogenesis of vascular changes in acquired cold urticaria.

  10. Neurosensory and vascular function after 14 months of military training comprising cold winter conditions.

    Science.gov (United States)

    Carlsson, Daniel; Pettersson, Hans; Burström, Lage; Nilsson, Tohr; Wahlström, Jens

    2016-01-01

    This study aimed to examine the effects of 14 months of military training comprising cold winter conditions on neurosensory and vascular function in the hands and feet. Military conscripts (N=54) were assessed with quantitative sensory testing comprising touch, temperature, and vibration perception thresholds and finger systolic blood pressure (FSBP) after local cooling and a questionnaire on neurosensory and vascular symptoms at both baseline and follow-up. Ambient air temperature was recorded with body worn temperature loggers. The subjects showed reduced sensitivity to perception of touch, warmth, cold and vibrations in both the hands and feet except from vibrotactile perception in digit two of the right hand (right dig 2). Cold sensations, white fingers, and pain/discomfort when exposed to cold as well as pain increased in both prevalence and severity. There were no statistically significant changes in FSBP after local cooling. Fourteen months of winter military training comprising cold winter conditions reduced sensation from touch, warmth, cold, and vibrotactile stimulus in both hands and feet and increased the severity and prevalence of symptoms and pain. The vascular function in the hands, measured by FSBP after local cooling, was not affected.

  11. Early outbreak detection by linking health advice line calls to water distribution areas retrospectively demonstrated in a large waterborne outbreak of cryptosporidiosis in Sweden

    Directory of Open Access Journals (Sweden)

    Pär Bjelkmar

    2017-04-01

    Full Text Available Abstract Background In the winter and spring of 2011 a large outbreak of cryptosporidiosis occurred in Skellefteå municipality, Sweden. This study summarizes the outbreak investigation in terms of outbreak size, duration, clinical characteristics, possible source(s and the potential for earlier detection using calls to a health advice line. Methods The investigation included two epidemiological questionnaires and microbial analysis of samples from patients, water and other environmental sources. In addition, a retrospective study based on phone calls to a health advice line was performed by comparing patterns of phone calls between different water distribution areas. Results Our analyses showed that approximately 18,500 individuals were affected by a waterborne outbreak of cryptosporidiosis in Skellefteå in 2011. This makes it the second largest outbreak of cryptosporidiosis in Europe to date. Cryptosporidium hominis oocysts of subtype IbA10G2 were found in patient and sewage samples, but not in raw water or in drinking water, and the initial contamination source could not be determined. The outbreak went unnoticed to authorities for several months. The analysis of the calls to the health advice line provides strong indications early in the outbreak that it was linked to a particular water treatment plant. Conclusions We conclude that an earlier detection of the outbreak by linking calls to a health advice line to water distribution areas could have limited the outbreak substantially.

  12. Control Measures Used during Lymphogranuloma Venereum Outbreak, Europe

    Science.gov (United States)

    Hulscher, Marlies E.J.L.; Vos, Dieuwke; van de Laar, Marita J.W.; Fenton, Kevin A.; van Steenbergen, Jim E.; van der Meer, Jos W.M.; Grol, Richard P.T.M.

    2008-01-01

    To assess the response to the reemergence of lymphogranuloma venereum, we conducted a cross-sectional survey by administering a structured questionnaire to representatives from 26 European countries. Responses were received from 18 countries. The ability to respond quickly and the measures used for outbreak detection and control varied. Evidence-based criteria were not consistently used to develop recommendations. We did not develop criteria to determine the effectiveness of the recommendations. The degree of preparedness for an unexpected outbreak, as well as the ability of countries to respond quickly to alerts, varied, which indicates weaknesses in the ability to control an outbreak. More guidance is needed to implement and evaluate control measures used during international outbreaks. PMID:18394274

  13. Surveillance and Outbreak Response Management System (SORMAS) to support the control of the Ebola virus disease outbreak in West Africa.

    Science.gov (United States)

    Fähnrich, C; Denecke, K; Adeoye, O O; Benzler, J; Claus, H; Kirchner, G; Mall, S; Richter, R; Schapranow, M P; Schwarz, N; Tom-Aba, D; Uflacker, M; Poggensee, G; Krause, G

    2015-03-26

    In the context of controlling the current outbreak of Ebola virus disease (EVD), the World Health Organization claimed that 'critical determinant of epidemic size appears to be the speed of implementation of rigorous control measures', i.e. immediate follow-up of contact persons during 21 days after exposure, isolation and treatment of cases, decontamination, and safe burials. We developed the Surveillance and Outbreak Response Management System (SORMAS) to improve efficiency and timeliness of these measures. We used the Design Thinking methodology to systematically analyse experiences from field workers and the Ebola Emergency Operations Centre (EOC) after successful control of the EVD outbreak in Nigeria. We developed a process model with seven personas representing the procedures of EVD outbreak control. The SORMAS system architecture combines latest In-Memory Database (IMDB) technology via SAP HANA (in-memory, relational database management system), enabling interactive data analyses, and established SAP cloud tools, such as SAP Afaria (a mobile device management software). The user interface consists of specific front-ends for smartphones and tablet devices, which are independent from physical configurations. SORMAS allows real-time, bidirectional information exchange between field workers and the EOC, ensures supervision of contact follow-up, automated status reports, and GPS tracking. SORMAS may become a platform for outbreak management and improved routine surveillance of any infectious disease. Furthermore, the SORMAS process model may serve as framework for EVD outbreak modeling.

  14. A Gastroenteritis Outbreak Caused by Noroviruses in Greece

    Directory of Open Access Journals (Sweden)

    Yiannis Alamanos

    2011-08-01

    Full Text Available In June 2006, an outbreak alert regarding cases of acute gastroenteritis in a region in North Eastern Greece (population 100,882 inhabitants, triggered investigations to guide control measures. The outbreak started the first days of June, and peaked in July. A descriptive epidemiological study, a virological characterization of the viral agent identified from cases as well as a phylogenetic analysis was performed. From June 5 to September 3, 2006 (weeks 23–44, 1,640 cases of gastroenteritis (45.2% male and 54.8% female, aged 3 months to 89 years were reported. The overall attack rate for the period was 16.3 cases/1,000 inhabitants. About 57% of cases observed were under the age of 15 years. Αnalysis of faecal samples identified Norovirus GII strains. Fifteen different Norovirus GII strains were recorded, presenting a homology of 94.8% (86–97% to GII strains obtained from GenBank. The long duration of the outbreak suggests an important role of person-to-person transmission, while the emergence of the outbreak was possibly due to contaminated potable water, although no viruses were detected in any tested water samples. This outbreak underscores the need for a national surveillance system for acute non-bacterial gastroenteritis outbreaks.

  15. Planning for smallpox outbreaks

    Science.gov (United States)

    Ferguson, Neil M.; Keeling, Matt J.; John Edmunds, W.; Gani, Raymond; Grenfell, Bryan T.; Anderson, Roy M.; Leach, Steve

    2003-10-01

    Mathematical models of viral transmission and control are important tools for assessing the threat posed by deliberate release of the smallpox virus and the best means of containing an outbreak. Models must balance biological realism against limitations of knowledge, and uncertainties need to be accurately communicated to policy-makers. Smallpox poses the particular challenge that key biological, social and spatial factors affecting disease spread in contemporary populations must be elucidated largely from historical studies undertaken before disease eradication in 1979. We review the use of models in smallpox planning within the broader epidemiological context set by recent outbreaks of both novel and re-emerging pathogens.

  16. Characteristics of pertussis outbreaks in Catalonia, Spain, 1997 to 2010.

    Science.gov (United States)

    Crespo, Inma; Broner, Sonia; Soldevila, Núria; Martínez, Ana; Godoy, Pere; Sala-Farré, Maria-Rosa; Company, Maria; Rius, Cristina; Domínguez, Angela; Group Of Catalonia, The Pertussis Working

    2015-01-01

    In Catalonia, pertussis outbreaks must be reported to the Department of Health. This study analyzed pertussis outbreaks between 1997 and 2010 in general and according to the characteristics of the index cases. The outbreak rate, hospitalization rate and incidence of associated cases and their 95%CI were calculated. Index cases were classified in two groups according to age (<15 years and ≥15 years) and the vaccine type received: whole cell vaccine (DTwP) or acellular vaccine (DTaP). During the study period, 230 outbreaks were reported. The outbreak rate was 2.43 × 10(-6) persons-year, and outbreaks ranged from 2 to 32 cases, with a median duration of 18 days. There were 771 associated cases, with an incidence rate of 0.8 × 10(-5) persons-year.   After classifying outbreaks according to the age of the index case, 126 outbreaks (1.3 × 10(-6) persons-year) had an index case aged <15 y and 87 (0.87 × 10(-6) person-year) had an index case aged ≥15 y (RR = 1.44, 95%CI 1.10-1.90; P = 0.007). Between 2003 and 2010, after the introduction of the acellular vaccine, the index case was vaccinated with DTwP vaccine in 25 outbreaks (0.43 × 10(-6) persons-year) and with DTaP vaccine in 32 outbreaks (0.55 × 10(-6) person-year) (RR = 0.78, 95%CI 0.46-1.31; P = 0.35). Of cases, 37.2% were correctly vaccinated, suggesting waning immunity of pertussis vaccine protection and endogenous circulation of pertussis. A greater number of outbreaks had an index case aged <15 y. No changes in the disease incidence, associated cases and hospitalization rate were observed after the introduction of DTaP.

  17. Typing of Salmonella enterica serovar Saintpaul: an outbreak investigation

    DEFF Research Database (Denmark)

    Baggesen, Dorte Lau; Wegener, Henrik Caspar; Christensen, J.P.

    1996-01-01

    factor, antibiogram typing, plasmid profiling, ribotyping and pulsed field gel electrophoresis, in order to identify the most probable source of infection. After typing, the source of the investigated outbreak remains obscure because so far no isolates with traits of the outbreak strain have been...... explanation for the failure to find isolates with traits of the outbreak strain could be the presence of a third, but so far unidentified, source. The present investigation illustrates the necessity of using more than one epidemiological typing method for outbreak investigation. This is especially important...

  18. Interaction of the psychrotroph Pseudomonas fluorescens In5 with phytopathogens in cold soils

    DEFF Research Database (Denmark)

    Hennessy, Rosanna Catherine; Olsson, Stefan; Stougaard, Peter

    Aim: Potato cultivation in southwest Greenland, at Inneruulalik, omits the use of pesticides while relying on limited crop rotations and despite the presence of plant pathogens in the soil does not suffer from major disease outbreaks. Previously, we have shown that the soil at Inneruulalik...... growth phase and upon physical encounter with fungal hyphae. Furthermore, the regulator is strongly upregulated in response to carbon sources indicating the presence of a fungus suggesting that environmental elicitors may also influence regulator expression, which upon activation controls nunamycin...... temperatures could lead to increased problems with soil-borne pathogens and importantly the application of synthetic fungicides in cold areas may be problematic due to slow degradation. Thus, the application of environmentally friendly biological control agents may provide an alternative sustainable solution...

  19. Outbreaks and Investigations

    Science.gov (United States)

    ... Who Gets Fungal Infections? People living with HIV/AIDS Organ Transplant Patients Cancer Patients Hospitalized Patients Stem Cell Transplant Patients Medications that Weaken Your Immune System Outbreaks Rhizopus Investigation CDC at Work Global Fungal Diseases Cryptococcal Meningitis ...

  20. Cholera outbreak in districts around Lake Chilwa, Malawi: Lessons ...

    African Journals Online (AJOL)

    Cholera is endemic in Malawi with seasonal outbreaks during the wet season. People living around Lake Chilwa rely on the lake for their water supply. From May 2009 to May 2010, a cholera outbreak occurred in fishing communities around Lake Chilwa. This paper describes the outbreak response and lessons learned for ...

  1. 2012 German refrigeration and air conditioning meeting. Proceedings; Deutsche Kaelte-Klima-Tagung 2012 Tagungsbericht

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2012-07-01

    Within the DKV conference of the Deutscher Kaelte- und Klimatechnischer Verein e.V. (Hanover, Federal Republic of Germany) from 21st to 23rd November, 2012, in Wuerzburg (Federal Republic of Germany) 121 lectures were held according to the following themes: Measurement and process control in cryotechnology; energy storage and energy application; application of cryotechnology in biology and medicine, new concepts and plants; fundamentals and materials for the technology of cold pumps and heat pumps - pool boiling; flow boiling / CO{sub 2}; adsorption processes; adsorption processes / phase change materials; condensation / dehumidification; plants and components of the technology of cold pumps and heat pumps - compressors; expansion and regulation; heat exchanger and reflux cooling; heat exchangers; systems simulation; systems and materials; application of cold - energy controlling / application; foodstuff / supermarket; air conditionings of passenger cars; air-conditioning of electric-powered automobiles; railway air-conditioning / system analyses; standardization and regulations; air conditioning and application of heat pumps - regulation / hardware-in-the-loop; net-zero-energy building; building engineering and simulation; standardization / IAQ / building materials; heat pumps; thermal comfort and performance in office accommodations.

  2. Impact of cold temperature on Euro 6 passenger car emissions.

    Science.gov (United States)

    Suarez-Bertoa, Ricardo; Astorga, Covadonga

    2018-03-01

    Hydrocarbons, CO, NOx, NH 3 , N 2 O, CO 2 and particulate matter emissions affect air quality, global warming and human health. Transport sector is an important source of these pollutants and high pollution episodes are often experienced during the cold season. However, EU vehicle emissions regulation at cold ambient temperature only addresses hydrocarbons and CO vehicular emissions. For that reason, we have studied the impact that cold ambient temperatures have on Euro 6 diesel and spark ignition (including: gasoline, ethanol flex-fuel and hybrid vehicles) vehicle emissions using the World-harmonized Light-duty Test Cycle (WLTC) at -7 °C and 23 °C. Results indicate that when facing the WLTC at 23 °C the tested vehicles present emissions below the values set for type approval of Euro 6 vehicles (still using NEDC), with the exception of NOx emissions from diesel vehicles that were 2.3-6 times higher than Euro 6 standards. However, emissions disproportionally increased when vehicles were tested at cold ambient temperature (-7 °C). High solid particle number (SPN) emissions (>1 × 10 11 # km -1 ) were measured from gasoline direct injection (GDI) vehicles and gasoline port fuel injection vehicles. However, only diesel and GDI SPN emissions are currently regulated. Results show the need for a new, technology independent, procedure that enables the authorities to assess pollutant emissions from vehicles at cold ambient temperatures. Harmful pollutant emissions from spark ignition and diesel vehicles are strongly and negatively affected by cold ambient temperatures. Only hydrocarbon, CO emissions are currently regulated at cold temperature. Therefore, it is of great importance to revise current EU winter vehicle emissions regulation. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.

  3. Development of the RRR cold neutron beam facility

    International Nuclear Information System (INIS)

    Lovotti, Osvaldo; Masriera, Nestor; Lecot, Carlos; Hergenreder, Daniel

    2002-01-01

    This paper describes some general design issues on the neutron beam facilities (cold neutron source and neutron beam transport system) of the Replacement Research Reactor (RRR) for the Australian Nuclear Science and Technology Organisation (ANSTO). The description covers different aspect of the design: the requirements that lead to an innovative design, the overall design itself, the definition of a technical approach in order to develop the necessary design solutions, and finally the organizational framework by which international expertise from five different institutions is integrated. From the technical viewpoint, the RRR-CNS is a liquid Deuterium (LD2) moderator, sub-cooled to ensure maximum moderation efficiency, flowing within a closed natural circulation thermosyphon loop. The thermosyphon is surrounded by a zirconium alloy CNS vacuum containment that provides thermal insulation and a multiple barriers scheme to prevent Deuterium from mixing with water or air. Consistent with international practice, this vessel is designed to withstand any hypothetical energy reaction should Deuterium and air mix in its interior. The 'cold' neutrons are then taken by the NBTS and transported by the neutron guide system into the reactor beam hall and neutron guide hall, where neutron scattering instruments are located. From the management viewpoint, the adopted distributed scheme is successful to manage the complex interfacing between highly specialized technologies, allowing a smooth integration within the project. (author)

  4. The indoor air we breathe.

    Science.gov (United States)

    Oliver, L C; Shackleton, B W

    1998-01-01

    Increasingly recognized as a potential public health problem since the outbreak of Legionnaire's disease in Philadelphia in 1976, polluted indoor air has been associated with health problems that include asthma, sick building syndrome, multiple chemical sensitivity, and hypersensitivity pneumonitis. Symptoms are often nonspecific and include headache, eye and throat irritation, chest tightness and shortness of breath, and fatigue. Air-borne contaminants include commonly used chemicals, vehicular exhaust, microbial organisms, fibrous glass particles, and dust. Identified causes include defective building design and construction, aging of buildings and their ventilation systems, poor climate control, inattention to building maintenance. A major contributory factor is the explosion in the use of chemicals in building construction and furnishing materials over the past four decades. Organizational issues and psychological variables often contribute to the problem and hinder its resolution. This article describes the health problems related to poor indoor air quality and offers solutions.

  5. Cognitive Performance during a 24-Hour Cold Exposure Survival Simulation

    Directory of Open Access Journals (Sweden)

    Michael J. Taber

    2016-01-01

    Full Text Available Survivor of a ship ground in polar regions may have to wait more than five days before being rescued. Therefore, the purpose of this study was to explore cognitive performance during prolonged cold exposure. Core temperature (Tc and cognitive test battery (CTB performance data were collected from eight participants during 24 hours of cold exposure (7.5°C ambient air temperature. Participants (recruited from those who have regular occupational exposure to cold were instructed that they could freely engage in minimal exercise that was perceived to maintaining a tolerable level of thermal comfort. Despite the active engagement, test conditions were sufficient to significantly decrease Tc after exposure and to eliminate the typical 0.5–1.0°C circadian rise and drop in core temperature throughout a 24 h cycle. Results showed minimal changes in CTB performance regardless of exposure time. Based on the results, it is recommended that survivors who are waiting for rescue should be encouraged to engage in mild physical activity, which could have the benefit of maintaining metabolic heat production, improve motivation, and act as a distractor from cold discomfort. This recommendation should be taken into consideration during future research and when considering guidelines for mandatory survival equipment regarding cognitive performance.

  6. [Norovirus outbreaks in hospitals and nursing homes in Catalonia, Spain].

    Science.gov (United States)

    Godoy, Pere; Domínguez, Angela; Alvarez, Josep; Camps, Neus; Barrabeig, Irene; Bartolomé, Rosa; Sala, María Rosa; Ferre, Dolors; Pañella, Helena; Torres, Joan; Minguell, Sofía; Alsedà, Miquel; Pumares, Analía

    2009-01-01

    The low infectious dose and multiple transmission routes favour the appearance of norovirus outbreaks. The objective of this study was to compare the incidence of norovirus outbreaks in hospitals and nursing homes in Catalonia. A descriptive study of norovirus outbreaks between 15/10/2004 and 30/10/2005 was carried out. An epidemiological survey was completed for each outbreak. Norovirus in clinical samples was determined by PCR techniques. The incidence in each centre and the annual incidence of outbreaks by centre were calculated. Differences were calculated using the chi-square test and the Student's t test, taking a p value of > 0.05 as significant. Seventeen outbreaks (6 in hospitals and 11 in nursing homes) were detected. The global attack rate was 33.4% (652/1951) and was slightly higher in nursing homes (35.2%) than in hospitals (31.4%). A total of 94.1% (16/17) of outbreaks were caused by person-to-person transmission and only 5.9% (1/17) by foods. The mean number of days between the first and last case was 11.4 (SD = 6.9). The mean duration of symptoms was 2.39 days (SD=1.6), and was higher hospitals, 2.63 (SD=1.7), than in nursing homes, 1.97 (SD=1.7) (p < 0.0001). Norovirus is responsible for a large number of outbreaks due to person-to-person transmission. Control should be standardized to reduce the number and duration of outbreaks.

  7. Nanopore Sequencing as a Rapidly Deployable Ebola Outbreak Tool.

    Science.gov (United States)

    Hoenen, Thomas; Groseth, Allison; Rosenke, Kyle; Fischer, Robert J; Hoenen, Andreas; Judson, Seth D; Martellaro, Cynthia; Falzarano, Darryl; Marzi, Andrea; Squires, R Burke; Wollenberg, Kurt R; de Wit, Emmie; Prescott, Joseph; Safronetz, David; van Doremalen, Neeltje; Bushmaker, Trenton; Feldmann, Friederike; McNally, Kristin; Bolay, Fatorma K; Fields, Barry; Sealy, Tara; Rayfield, Mark; Nichol, Stuart T; Zoon, Kathryn C; Massaquoi, Moses; Munster, Vincent J; Feldmann, Heinz

    2016-02-01

    Rapid sequencing of RNA/DNA from pathogen samples obtained during disease outbreaks provides critical scientific and public health information. However, challenges exist for exporting samples to laboratories or establishing conventional sequencers in remote outbreak regions. We successfully used a novel, pocket-sized nanopore sequencer at a field diagnostic laboratory in Liberia during the current Ebola virus outbreak.

  8. Burning Cold: Involvement of TRPA1 in Noxious Cold Sensation

    OpenAIRE

    Kwan, Kelvin Y.; Corey, David P.

    2009-01-01

    Soon after its discovery ten years ago, the ion channel TRPA1 was proposed as a sensor of noxious cold. Evidence for its activation by painfully cold temperatures (below ~15° C) has been mixed, however. Some groups found that cold elicits a nonselective conductance in cells expressing TRPA1; others found no activation, or argued that activation is an indirect effect of elevated \\(Ca^{ 2+}\\) . Sensory cells from the trigeminal and dorsal root ganglia that are activated by cold were sometimes c...

  9. Management of Animal Botulism Outbreaks: From Clinical Suspicion to Practical Countermeasures to Prevent or Minimize Outbreaks

    DEFF Research Database (Denmark)

    Anniballi, Fabrizio; Fiore, Alfonsina; Löfström, Charlotta

    2013-01-01

    and economic concern because of its high mortality rate. Moreover, meat or other products from affected animals entering the food chain may result in a public health problem. To this end, early diagnosis is crucial to define and apply appropriate veterinary public health measures. Clinical diagnosis is based...... outbreaks. In this article we outline all phases of management of animal botulism outbreaks occurring in wet wild birds, poultry, cattle, horses, and fur farm animals....

  10. Tuberculosis Outbreak Investigations in the U.S.

    Centers for Disease Control (CDC) Podcasts

    2011-02-22

    In this podcast, Dr Kiren Mitruka, medical officer with CDC's Tuberculosis Outbreak Investigations team, discusses tuberculosis outbreak investigations in the U.S. from 2002-2008.  Created: 2/22/2011 by National Center for Emerging Zoonotic and Infectious Diseases (NCEZID).   Date Released: 3/22/2011.

  11. Cold-Hearted or Cool-Headed: Physical Coldness Promotes Utilitarian Moral Judgment

    Directory of Open Access Journals (Sweden)

    Hiroko eNakamura

    2014-10-01

    Full Text Available In the current study, we examine the effect of physical coldness on personal moral dilemma judgment. Previous studies have indicated that utilitarian moral judgment—sacrificing a few people to achieve the greater good for others—was facilitated when: (1 participants suppressed an initial emotional response and deliberately thought about the utility of outcomes; (2 participants had a high-level construal mindset and focused on abstract goals (e.g., save many; or (3 there was a decreasing emotional response to sacrificing a few. In two experiments, we exposed participants to extreme cold or typical room temperature and then asked them to make personal moral dilemma judgments. The results of Experiment 1 indicated that coldness prompted utilitarian judgment, but the effect of coldness was independent from deliberate thought or abstract high-level construal mindset. As Experiment 2 revealed, coldness facilitated utilitarian judgment via reduced empathic feelings. Therefore, physical coldness did not affect the cool-headed deliberate process or the abstract high-level construal mindset. Rather, coldness biased people toward being cold-hearted, reduced empathetic concern about a sacrificed victim, and facilitated utilitarian moral judgments.

  12. Cost of dengue outbreaks: literature review and country case studies.

    Science.gov (United States)

    Stahl, Hans-Christian; Butenschoen, Vicki Marie; Tran, Hien Tinh; Gozzer, Ernesto; Skewes, Ronald; Mahendradhata, Yodi; Runge-Ranzinger, Silvia; Kroeger, Axel; Farlow, Andrew

    2013-11-06

    Dengue disease surveillance and vector surveillance are presumed to detect dengue outbreaks at an early stage and to save--through early response activities--resources, and reduce the social and economic impact of outbreaks on individuals, health systems and economies. The aim of this study is to unveil evidence on the cost of dengue outbreaks. Economic evidence on dengue outbreaks was gathered by conducting a literature review and collecting information on the costs of recent dengue outbreaks in 4 countries: Peru, Dominican Republic, Vietnam, and Indonesia. The literature review distinguished between costs of dengue illness including cost of dengue outbreaks, cost of interventions and cost-effectiveness of interventions. Seventeen publications on cost of dengue showed a large range of costs from 0.2 Million US$ in Venezuela to 135.2 Million US$ in Brazil. However, these figures were not standardized to make them comparable. Furthermore, dengue outbreak costs are calculated differently across the publications, and cost of dengue illness is used interchangeably with cost of dengue outbreaks. Only one paper from Australia analysed the resources saved through active dengue surveillance. Costs of vector control interventions have been reported in 4 studies, indicating that the costs of such interventions are lower than those of actual outbreaks. Nine papers focussed on the cost-effectiveness of dengue vaccines or dengue vector control; they do not provide any direct information on cost of dengue outbreaks, but their modelling methodologies could guide future research on cost-effectiveness of national surveillance systems.The country case studies--conducted in very different geographic and health system settings - unveiled rough estimates for 2011 outbreak costs of: 12 million US$ in Vietnam, 6.75 million US$ in Indonesia, 4.5 million US$ in Peru and 2.8 million US$ in Dominican Republic (all in 2012 US$). The proportions of the different cost components (vector control

  13. Grasshopper species composition shifts following a severe rangeland grasshopper outbreak

    Science.gov (United States)

    Little is known about how grasshopper species abundances shift during and following severe outbreaks, as sampling efforts usually end when outbreaks subside. Grasshopper densities, species composition and vegetation have infrequently been sampled during and after a severe outbreak in the western U.S...

  14. The impact of winter cold weather on acute myocardial infarctions in Portugal

    International Nuclear Information System (INIS)

    Vasconcelos, João; Freire, Elisabete; Almendra, Ricardo

    2013-01-01

    Mortality due to cardiovascular diseases shows a seasonal trend that can be associated with cold weather. Portugal is the European country with the highest excess winter mortality, but nevertheless, the relationship between cold weather and health is yet to be assessed. The main aim of this study is to identify the contribution of cold weather to cardiovascular diseases within Portugal. Poisson regression analysis based on generalized additive models was applied to estimate the influence of a human-biometeorological index (PET) on daily hospitalizations for myocardial infarction. The main results revealed a negative effect of cold weather on acute myocardial infarctions in Portugal. For every degree fall in PET during winter, there was an increase of up to 2.2% (95% CI = 0.9%; 3.3%) in daily hospital admissions. This paper shows the need for public policies that will help minimize or, indeed, prevent exposure to cold. -- Highlights: ► We model the relationship between daily hospitalizations due to myocardial infarctions and cold weather in Portugal. ► We use Physiological Equivalent temperature (PET) as main explanatory variable. ► We adjust the models to confounding factors such as influenza and air pollution. ► Daily hospitalizations increased up to 2.2% per degree fall of PET during winter. ► Exposure to cold weather has a negative impact on human health in Portugal. -- There is an increase of up to 2.2% in daily hospitalizations due to acute myocardial infarctions per degree fall of thermal index during the winter months in Portugal

  15. The Methanol Poisoning Outbreaks in Libya 2013 and Kenya 2014.

    Science.gov (United States)

    Rostrup, Morten; Edwards, Jeffrey K; Abukalish, Mohamed; Ezzabi, Masoud; Some, David; Ritter, Helga; Menge, Tom; Abdelrahman, Ahmed; Rootwelt, Rebecca; Janssens, Bart; Lind, Kyrre; Paasma, Raido; Hovda, Knut Erik

    2016-01-01

    Outbreaks of methanol poisoning occur frequently on a global basis, affecting poor and vulnerable populations. Knowledge regarding methanol is limited, likely many cases and even outbreaks go unnoticed, with patients dying unnecessarily. We describe findings from the first three large outbreaks of methanol poisoning where Médecins Sans Frontières (MSF) responded, and evaluate the benefits of a possible future collaboration between local health authorities, a Non-Governmental Organisation and international expertise. Retrospective study of three major methanol outbreaks in Libya (2013) and Kenya (May and July 2014). Data were collected from MSF field personnel, local health personnel, hospital files, and media reports. In Tripoli, Libya, over 1,000 patients were poisoned with a reported case fatality rate of 10% (101/1,066). In Kenya, two outbreaks resulted in approximately 341 and 126 patients, with case fatality rates of 29% (100/341) and 21% (26/126), respectively. MSF launched an emergency team with international experts, medications and equipment, however, the outbreaks were resolving by the time of arrival. Recognition of an outbreak of methanol poisoning and diagnosis seem to be the most challenging tasks, with significant delay from time of first presentations to public health warnings being issued. In spite of the rapid response from an emergency team, the outbreaks were nearly concluded by the time of arrival. A major impact on the outcome was not seen, but large educational trainings were conducted to increase awareness and knowledge about methanol poisoning. Based on this training, MSF was able to send a local emergency team during the second outbreak, supporting that such an approach could improve outcomes. Basic training, simplified treatment protocols, point-of-care diagnostic tools, and early support when needed, are likely the most important components to impact the consequences of methanol poisoning outbreaks in these challenging contexts.

  16. Estimated Cost to a Restaurant of a Foodborne Illness Outbreak.

    Science.gov (United States)

    Bartsch, Sarah M; Asti, Lindsey; Nyathi, Sindiso; Spiker, Marie L; Lee, Bruce Y

    Although outbreaks of restaurant-associated foodborne illness occur periodically and make the news, a restaurant may not be aware of the cost of an outbreak. We estimated this cost under varying circumstances. We developed a computational simulation model; scenarios varied outbreak size (5 to 250 people affected), pathogen (n = 15), type of dining establishment (fast food, fast casual, casual dining, and fine dining), lost revenue (ie, meals lost per illness), cost of lawsuits and legal fees, fines, and insurance premium increases. We estimated that the cost of a single foodborne illness outbreak ranged from $3968 to $1.9 million for a fast-food restaurant, $6330 to $2.1 million for a fast-casual restaurant, $8030 to $2.2 million for a casual-dining restaurant, and $8273 to $2.6 million for a fine-dining restaurant, varying from a 5-person outbreak, with no lost revenue, lawsuits, legal fees, or fines, to a 250-person outbreak, with high lost revenue (100 meals lost per illness), and a high amount of lawsuits and legal fees ($1 656 569) and fines ($100 000). This cost amounts to 10% to 5790% of a restaurant's annual marketing costs and 0.3% to 101% of annual profits and revenue. The biggest cost drivers were lawsuits and legal fees, outbreak size, and lost revenue. Pathogen type affected the cost by a maximum of $337 000, the difference between a Bacillus cereus outbreak (least costly) and a listeria outbreak (most costly). The cost of a single foodborne illness outbreak to a restaurant can be substantial and outweigh the typical costs of prevention and control measures. Our study can help decision makers determine investment and motivate research for infection-control measures in restaurant settings.

  17. Hepatitis A outbreaks in the vaccination era in Catalonia, Spain.

    Science.gov (United States)

    Martínez, Ana; Broner, Sonia; Torner, Nuria; Godoy, Pere; Batalla, Joan; Alvarez, Josep; Barrabeig, Irene; Camps, Neus; Carmona, Gloria; Minguell, Sofía; Sala, Rosa; Caylà, Joan; Domínguez, Angela

    2011-01-01

    Hepatitis A outbreaks have a major impact on public health services and involve case investigation and intervention measures to susceptible contacts. At the end of 1998 a universal vaccination program with a combined hepatitis A+B vaccine was started in Catalonia (Spain) in 12-years-old preadolescents. The objective of this study was to compare the characteristics of hepatitis A outbreaks in the periods before and after the introduction of the preadolescent vaccination program and to estimate the preventable fraction of cases associated to outbreaks. The incidence rates of outbreaks, cases and hospitalization associated with each outbreak were calculated. Two periods were considered: before (1991-1998) and after (2000-2007) the introduction of mass vaccination. The preventable fraction and 95% confidence intervals (CI) of cases associated with outbreaks was calculated. The rate of associated cases with outbreaks was higher in the period before the vaccination program than in the post vaccination period (1.53 per 100,000 person-year vs 1.12 ; pcases associated to outbreaks was 19.6%(95%CI 6.7-32.5) in the 0-4 years group and 16.7% (95% CI 6.0-27.5) in the 5-14 years group, but the highest figure (38.6%; 95%CI 21.3-55.9) was observed in the 15-24 years age group. The estimated proportion of cases associated with outbreaks that would theoretically have been prevented with the vaccination program suggests that substantial benefits have been obtained in Catalonia in people aged less than 25 years.

  18. Cold Vacuum Drying facility condensate collection system design description (SYS 19); FINAL

    International Nuclear Information System (INIS)

    PITKOFF, C.C.

    1999-01-01

    This document describes the Cold Vacuum Drying Facility (CVDF) condensate collection system (CCS). The function of the CCS is to collect cooling coil condensate from air-handling units in the CVDF and to isolate the condensate in collection tanks until the condensate is determined to be acceptable to drain to the effluent drain collection basin

  19. Tularaemia outbreaks in Sakarya, Turkey: case-control and environmental studies.

    Science.gov (United States)

    Meric, M; Sayan, M; Dundar, D; Willke, A

    2010-08-01

    Tularaemia is an important zoonotic disease that leads to outbreaks. This study aimed to compare the epidemiological characteristics of two tularaemia outbreaks that occurred in the Sakarya region of Turkey, analyse the risk factors for the development of outbreaks and identify Francisella (F.) tularensis in the water samples. Two tularaemia outbreaks occurred in the Kocadongel village in 2005 and 2006. A field investigation and a case-control study with 47 cases and 47 healthy households were performed during the second outbreak. Clinical samples from the patients and filtrated water samples were analysed for F. tularensis via real-time polymerase chain reaction. From the two outbreaks, a total of 58 patients were diagnosed with oropharyngeal tularaemia based on their clinical and serological results. Both outbreaks occurred between the months of January and April, and the number of patients peaked in February. Logistic regression analysis revealed that the consumption of natural spring water was the only significant risk factor for tularaemia infection (odds ratio 3.5, confidence interval 1.23-10.07). F. tularensis was detected in eight clinical samples and in the filtrated natural spring water. This study is the first report of tularaemia from this region. The results show that both tularaemia outbreaks were related to the consumption of untreated natural spring water. To prevent waterborne tularaemia, community water supplies should be treated and checked periodically.

  20. Molecular Investigation of Tularemia Outbreaks, Spain, 1997–2008

    Science.gov (United States)

    Ariza-Miguel, Jaime; Johansson, Anders; Fernández-Natal, María Isabel; Martínez-Nistal, Carmen; Orduña, Antonio; Rodríguez-Ferri, Elías F.; Hernández, Marta

    2014-01-01

    Tularemia outbreaks occurred in northwestern Spain in 1997–1998 and 2007–2008 and affected >1,000 persons. We assessed isolates involved in these outbreaks by using pulsed-field gel electrophoresis with 2 restriction enzymes and multilocus variable number tandem repeat analysis of 16 genomic loci of Francisella tularensis, the cause of this disease. Isolates were divided into 3 pulsotypes by pulsed-field gel electrophoresis and 8 allelic profiles by multilocus variable number tandem repeat analysis. Isolates obtained from the second tularemia outbreak had the same genotypes as isolates obtained from the first outbreak. Both outbreaks were caused by genotypes of genetic subclade B.Br:FTNF002–00, which is widely distributed in countries in central and western Europe. Thus, reemergence of tularemia in Spain was not caused by the reintroduction of exotic strains, but probably by persistence of local reservoirs of infection. PMID:24750848

  1. Outbreak of Burkholderia cepacia complex bacteremia in a chemotherapy day care unit due to intrinsic contamination of an antiemetic drug

    Directory of Open Access Journals (Sweden)

    T Singhal

    2015-01-01

    Full Text Available Background: In the end of 2009, a large number of patients with cancer undergoing chemotherapy at the day care unit of a private hospital in Mumbai, India developed Burkholderia cepacia complex (BCC blood stream infection (BSI. Objective: The objectives were to identify the source of the outbreak and terminate the outbreak as rapidly as possible. Materials and Methods: All infection control protocols and processes were reviewed. Intensive training was started for all nursing staff involved in patient care. Cultures were sent from the environment (surfaces, water, air, intravenous fluids, disinfectants and antiseptics and opened/unopened medication. Results: A total of 13 patients with cancer with tunneled catheters were affected with BCC BSI. The isolates were of similar antimicrobial sensitivity. No significant breach of infection control protocols could be identified. Cultures from the prepared intravenous medication bags grew BCC. Subsequently, culture from unused vials of the antiemetic granisetron grew BCC, whereas those from the unopened IV fluid bag and chemotherapy medication were negative. On review, it was discovered that the outbreak started when a new brand of granisetron was introduced. The result was communicated to the manufacturer and the brand was withdrawn. There were no further cases. Conclusions: This outbreak was thus linked to intrinsic contamination of medication vials. We acknowledge a delay in identifying the source as we were concentrating more on human errors in medication preparation and less on intrinsic contamination. We recommend that in an event of an outbreak, unopened vials be cultured at the outset.

  2. Grooved cold moderator tests

    International Nuclear Information System (INIS)

    Inoue, K.; Kiyanagi, Y.; Iwasa, H.; Watanabe, N.; Ikeda, S.; Carpenter, J.M.; Ishikawa, Y.

    1983-01-01

    We performed some grooved cold moderator experiments for methane at 20 K by using the Hokkaido University linac to obtain information to be used in the planning of the KENS-I' project. Cold neutron gains, spatial distribution of emitted beams and time distribution of the neutrons in the grooved cold moderator were measured. Furthermore, we assessed the effects of the grooved cold moderator on the performances of the spectrometers presently installed at the KENS-I cold source. We concluded that the grooved cold moderator benefited appreciably the performances of the spectrometers

  3. Epidemiology of bacterial toxin-mediated foodborne gastroenteritis outbreaks in Australia, 2001 to 2013.

    Science.gov (United States)

    May, Fiona J; Polkinghorne, Benjamin G; Fearnley, Emily J

    2016-12-24

    Bacterial toxin-mediated foodborne outbreaks, such as those caused by Clostridium perfringens, Staphylococcus aureus and Bacillus cereus, are an important and preventable cause of morbidity and mortality. Due to the short incubation period and duration of illness, these outbreaks are often under-reported. This is the first study to describe the epidemiology of bacterial toxin-mediated outbreaks in Australia. Using data collected between 2001 and 2013, we identify high risk groups and risk factors to inform prevention measures. Descriptive analyses of confirmed bacterial toxin-mediated outbreaks between 2001 and 2013 were undertaken using data extracted from the OzFoodNet Outbreak Register, a database of all outbreaks of gastrointestinal disease investigated by public health authorities in Australia. A total of 107 laboratory confirmed bacterial toxin-mediated outbreaks were reported between 2001 and 2013, affecting 2,219 people, including 47 hospitalisations and 13 deaths. Twelve deaths occurred in residents of aged care facilities. Clostridium perfringens was the most commonly reported aetiological agent (81 outbreaks, 76%). The most commonly reported food preparation settings were commercial food preparation services (51 outbreaks, 48%) and aged care facilities (42 outbreaks, 39%). Bacterial toxin outbreaks were rarely associated with food preparation in the home (2 outbreaks, 2%). In all outbreaks, the primary factor contributing to the outbreak was inadequate temperature control of the food. Public health efforts aimed at improving storage and handling practices for pre-cooked and re-heated foods, especially in commercial food preparation services and aged care facilities, could help to reduce the magnitude of bacterial toxin outbreaks.

  4. Acute effects of low-level sulphur dioxide and nitrogen dioxide exposures on the respiratory tract of susceptible subjects in cold environments

    Energy Technology Data Exchange (ETDEWEB)

    Salonen, R.O.; Randell, J.T.; Haelinen, A.I.; Pennanen, A.S. [National Public Health Inst., Kuopio (Finland). Div. of Environmental Health; Kosma, V.M. [Kuopio Univ. (Finland). Dept. of Pathology; Pekkarinen, H. [Kuopio Univ. (Finland). Dept. of Physiology; Ruuskanen, J. [Kuopio Univ. (Finland). Dept. of Environmental Sciences; Tukiainen, H. [Kuopio Univ. (Finland). Dept. of Pulmonary Diseases

    1995-12-31

    Several recent epidemiological studies from Finland have suggested that sulphur dioxide (SO{sub 2}) and nitrogen dioxide (NO{sub 2}) cause adverse health effects in susceptible population groups, such as children and asthmatic patients, at much smaller concentrations than the present guideline values of the World Health Organization. One possible explanation of these findings is that the relatively long winter-time increases the sensitivity of the respiratory tract to irritant pollutants. This hypothesis is supported by experimental human and animal studies, which have shown obstruction and inflammatory changes in the conducting airways after ventilation of cold and dry air. Asthmatic patients are much more sensitive than healthy subjects to the irritating effects of cold and dry air and of air pollutants. The airways of many non-asthmatic a topic subjects are also sensitive to cold air, but these subjects are poorly defined as a potential susceptible population group to air pollutants. The aims of this project are: (1) to construct experimental human and animal facilities and protocols for short-term studies on SO{sub 2} and NO{sub 2} exposures at subfreezing temperatures, (2) to apply advanced lung function methodologies and symptom assessment for characterisation of short-term respiratory responses of asthmatic and a topic subjects to these exposures, (3) to apply well-established pulmonary physiological, cytological and morphological methods for characterisation of short-term responses to and mechanisms of these exposures in the guinea-pig lower airways. (author)

  5. Acute effects of low-level sulphur dioxide and nitrogen dioxide exposures on the respiratory tract of susceptible subjects in cold environments

    Energy Technology Data Exchange (ETDEWEB)

    Salonen, R O; Randell, J T; Haelinen, A I; Pennanen, A S [National Public Health Inst., Kuopio (Finland). Div. of Environmental Health; Kosma, V M [Kuopio Univ. (Finland). Dept. of Pathology; Pekkarinen, H [Kuopio Univ. (Finland). Dept. of Physiology; Ruuskanen, J [Kuopio Univ. (Finland). Dept. of Environmental Sciences; Tukiainen, H [Kuopio Univ. (Finland). Dept. of Pulmonary Diseases

    1996-12-31

    Several recent epidemiological studies from Finland have suggested that sulphur dioxide (SO{sub 2}) and nitrogen dioxide (NO{sub 2}) cause adverse health effects in susceptible population groups, such as children and asthmatic patients, at much smaller concentrations than the present guideline values of the World Health Organization. One possible explanation of these findings is that the relatively long winter-time increases the sensitivity of the respiratory tract to irritant pollutants. This hypothesis is supported by experimental human and animal studies, which have shown obstruction and inflammatory changes in the conducting airways after ventilation of cold and dry air. Asthmatic patients are much more sensitive than healthy subjects to the irritating effects of cold and dry air and of air pollutants. The airways of many non-asthmatic a topic subjects are also sensitive to cold air, but these subjects are poorly defined as a potential susceptible population group to air pollutants. The aims of this project are: (1) to construct experimental human and animal facilities and protocols for short-term studies on SO{sub 2} and NO{sub 2} exposures at subfreezing temperatures, (2) to apply advanced lung function methodologies and symptom assessment for characterisation of short-term respiratory responses of asthmatic and a topic subjects to these exposures, (3) to apply well-established pulmonary physiological, cytological and morphological methods for characterisation of short-term responses to and mechanisms of these exposures in the guinea-pig lower airways. (author)

  6. Foodborne Norovirus Outbreaks

    Centers for Disease Control (CDC) Podcasts

    2012-09-17

    Dr. Aron Hall, a CDC epidemiologist specializing in noroviruses, discusses foodborne norovirus outbreaks.  Created: 9/17/2012 by National Center for Emerging and Zoonotic Infectious Diseases (NCEZID); National Center for Immunization and Respiratory Diseases (NCIRD).   Date Released: 9/17/2012.

  7. Outbreak of caliciviruses in the Singapore military, 2015.

    Science.gov (United States)

    Neo, Freddy Jun Xian; Loh, Jimmy Jin Phang; Ting, Peijun; Yeo, Wei Xin; Gao, Christine Qiu Han; Lee, Vernon Jian Ming; Tan, Boon Huan; Ng, Ching Ging

    2017-11-14

    From 31 August to 9 September 2015, a total of 150 military personnel at a military institution in Singapore were infected with acute gastroenteritis (AGE) with an attack rate of approximately 3%. This study aimed to determine the epidemiology of the outbreak, investigate its origins, and discuss measures to prevent future occurrences. After the AGE outbreak was declared on 31 August 2015, symptom surveys, hygiene inspections, and the testing of water, food, and stool samples were initiated. We collected 86 stool samples from AGE cases and 58 samples from food-handlers during the course of the outbreak and these stool samples were tested for 8 bacterial pathogens and 2 viral pathogens (i.e., norovirus and sapovirus). We detected Sapovirus (SaV), group I Norovirus (NoV GI) and group II Norovirus (NoV GII) from the stool samples of AGE cases. Further sequence analyses showed that the AGE outbreak in August was caused mainly by three rarely reported calicivirus novel genotypes: NoV GI.7, NoV GII.17 and SaV GII.3. Control measures implemented focused on the escalation of personal and environmental hygiene, which included the separation of affected and unaffected soldiers, enforcement of rigorous hand-washing and hygiene, raising awareness of food and water safety, and disinfection of communal areas with bleach. This study identified both NoV and SaV as the causative agents for an AGE outbreak at a Singapore military camp in August 2015. This study is also the first to report SaV as one of the main causative agents, highlighting the importance of caliciviruses as causative agents of AGE outbreaks in the Singapore military. As there are no commercially available vaccines against caliciviruses, strict personal hygiene and proper disinfection of environmental surfaces remain crucial to prevent calicivirus outbreak and transmission.

  8. Model-specification uncertainty in future forest pest outbreak.

    Science.gov (United States)

    Boulanger, Yan; Gray, David R; Cooke, Barry J; De Grandpré, Louis

    2016-04-01

    Climate change will modify forest pest outbreak characteristics, although there are disagreements regarding the specifics of these changes. A large part of this variability may be attributed to model specifications. As a case study, we developed a consensus model predicting spruce budworm (SBW, Choristoneura fumiferana [Clem.]) outbreak duration using two different predictor data sets and six different correlative methods. The model was used to project outbreak duration and the uncertainty associated with using different data sets and correlative methods (=model-specification uncertainty) for 2011-2040, 2041-2070 and 2071-2100, according to three forcing scenarios (RCP 2.6, RCP 4.5 and RCP 8.5). The consensus model showed very high explanatory power and low bias. The model projected a more important northward shift and decrease in outbreak duration under the RCP 8.5 scenario. However, variation in single-model projections increases with time, making future projections highly uncertain. Notably, the magnitude of the shifts in northward expansion, overall outbreak duration and the patterns of outbreaks duration at the southern edge were highly variable according to the predictor data set and correlative method used. We also demonstrated that variation in forcing scenarios contributed only slightly to the uncertainty of model projections compared with the two sources of model-specification uncertainty. Our approach helped to quantify model-specification uncertainty in future forest pest outbreak characteristics. It may contribute to sounder decision-making by acknowledging the limits of the projections and help to identify areas where model-specification uncertainty is high. As such, we further stress that this uncertainty should be strongly considered when making forest management plans, notably by adopting adaptive management strategies so as to reduce future risks. © 2015 Her Majesty the Queen in Right of Canada Global Change Biology © 2015 Published by John

  9. Cost of dengue outbreaks: literature review and country case studies

    Science.gov (United States)

    2013-01-01

    Background Dengue disease surveillance and vector surveillance are presumed to detect dengue outbreaks at an early stage and to save – through early response activities – resources, and reduce the social and economic impact of outbreaks on individuals, health systems and economies. The aim of this study is to unveil evidence on the cost of dengue outbreaks. Methods Economic evidence on dengue outbreaks was gathered by conducting a literature review and collecting information on the costs of recent dengue outbreaks in 4 countries: Peru, Dominican Republic, Vietnam, and Indonesia. The literature review distinguished between costs of dengue illness including cost of dengue outbreaks, cost of interventions and cost-effectiveness of interventions. Results Seventeen publications on cost of dengue showed a large range of costs from 0.2 Million US$ in Venezuela to 135.2 Million US$ in Brazil. However, these figures were not standardized to make them comparable. Furthermore, dengue outbreak costs are calculated differently across the publications, and cost of dengue illness is used interchangeably with cost of dengue outbreaks. Only one paper from Australia analysed the resources saved through active dengue surveillance. Costs of vector control interventions have been reported in 4 studies, indicating that the costs of such interventions are lower than those of actual outbreaks. Nine papers focussed on the cost-effectiveness of dengue vaccines or dengue vector control; they do not provide any direct information on cost of dengue outbreaks, but their modelling methodologies could guide future research on cost-effectiveness of national surveillance systems. The country case studies – conducted in very different geographic and health system settings - unveiled rough estimates for 2011 outbreak costs of: 12 million US$ in Vietnam, 6.75 million US$ in Indonesia, 4.5 million US$ in Peru and 2.8 million US$ in Dominican Republic (all in 2012 US$). The proportions of the

  10. Improving the wettability of 2024 aluminium alloy by means of cold plasma treatment

    Science.gov (United States)

    Polini, W.; Sorrentino, L.

    2003-05-01

    Aluminium alloys are heavily used to manufacture structural parts in the aeronautic industry because of its lightness and its corrosion resistance. These alloys are successfully used in other industrial fields too, such as railway, automotive and naval industries. The need to contrast the severe use conditions and the heavy stresses developing in aeronautic field implies to protect the surfaces of the structures in aluminium alloy by any deterioration. To preserve by deterioration, it is necessary to make aluminium more suitable to be coated by protective paint. In the aeronautic industry, a complex and critical process is used in order to enhance both wettability and adhesive properties of aluminium alloy surfaces. Cold plasma treatment represents an efficient, clean and economic alternative to activate aluminium surfaces. The present work deals with air cold plasma treatment of 2024 aluminium alloy surfaces. The influence of dc electrical discharge cold plasma parameters on wettability of 2024 aluminium alloy surfaces has been studied. A set of process variables (voltage, time and air flow rate) has been identified and used to conduct some experimental tests on the basis of design of experiment (DOE) techniques. The experimental results show that the proposed plasma process may considerably increase aluminium alloy wettability. These results represent the first step in trying to optimise the aluminium adhesion by means of this non-conventional manufacturing process.

  11. Cost-Analysis of Seven Nosocomial Outbreaks in an Academic Hospital.

    Science.gov (United States)

    Dik, Jan-Willem H; Dinkelacker, Ariane G; Vemer, Pepijn; Lo-Ten-Foe, Jerome R; Lokate, Mariëtte; Sinha, Bhanu; Friedrich, Alex W; Postma, Maarten J

    2016-01-01

    Nosocomial outbreaks, especially with (multi-)resistant microorganisms, are a major problem for health care institutions. They can cause morbidity and mortality for patients and controlling these costs substantial amounts of funds and resources. However, how much is unclear. This study sets out to provide a comparable overview of the costs of multiple outbreaks in a single academic hospital in the Netherlands. Based on interviews with the involved staff, multiple databases and stored records from the Infection Prevention Division all actions undertaken, extra staff employment, use of resources, bed-occupancy rates, and other miscellaneous cost drivers during different outbreaks were scored and quantified into Euros. This led to total costs per outbreak and an estimated average cost per positive patient per outbreak day. Seven outbreaks that occurred between 2012 and 2014 in the hospital were evaluated. Total costs for the hospital ranged between €10,778 and €356,754. Costs per positive patient per outbreak day, ranged between €10 and €1,369 (95% CI: €49-€1,042), with a mean of €546 and a median of €519. Majority of the costs (50%) were made because of closed beds. This analysis is the first to give a comparable overview of various outbreaks, caused by different microorganisms, in the same hospital and all analyzed with the same method. It shows a large variation within the average costs due to different factors (e.g. closure of wards, type of ward). All outbreaks however cost considerable amounts of efforts and money (up to €356,754), including missed revenue and control measures.

  12. Cost-Analysis of Seven Nosocomial Outbreaks in an Academic Hospital.

    Directory of Open Access Journals (Sweden)

    Jan-Willem H Dik

    Full Text Available Nosocomial outbreaks, especially with (multi-resistant microorganisms, are a major problem for health care institutions. They can cause morbidity and mortality for patients and controlling these costs substantial amounts of funds and resources. However, how much is unclear. This study sets out to provide a comparable overview of the costs of multiple outbreaks in a single academic hospital in the Netherlands.Based on interviews with the involved staff, multiple databases and stored records from the Infection Prevention Division all actions undertaken, extra staff employment, use of resources, bed-occupancy rates, and other miscellaneous cost drivers during different outbreaks were scored and quantified into Euros. This led to total costs per outbreak and an estimated average cost per positive patient per outbreak day.Seven outbreaks that occurred between 2012 and 2014 in the hospital were evaluated. Total costs for the hospital ranged between €10,778 and €356,754. Costs per positive patient per outbreak day, ranged between €10 and €1,369 (95% CI: €49-€1,042, with a mean of €546 and a median of €519. Majority of the costs (50% were made because of closed beds.This analysis is the first to give a comparable overview of various outbreaks, caused by different microorganisms, in the same hospital and all analyzed with the same method. It shows a large variation within the average costs due to different factors (e.g. closure of wards, type of ward. All outbreaks however cost considerable amounts of efforts and money (up to €356,754, including missed revenue and control measures.

  13. Crisis prevention and management during SARS outbreak, Singapore.

    Science.gov (United States)

    Quah, Stella R; Hin-Peng, Lee

    2004-02-01

    We discuss crisis prevention and management during the first 3 months of the severe acute respiratory syndrome (SARS) outbreak in Singapore. Four public health issues were considered: prevention measures, self-health evaluation, SARS knowledge, and appraisal of crisis management. We conducted telephone interviews with a representative sample of 1,201 adults, > or = 21 years of age. We found that sex, age, and attitude (anxiety and perception of open communication with authorities) were associated with practicing preventive measures. Analysis of Singapore's outbreak improves our understanding of the social dimensions of infectious disease outbreaks.

  14. Trends and Variability of North Pacific Polar Lows

    Directory of Open Access Journals (Sweden)

    Fei Chen

    2013-01-01

    Full Text Available The 6-hourly 1948–2010 NCEP 1 reanalyses have been dynamically downscaled for the region of the North Pacific. With a detecting-and-tracking algorithm, the climatology of North Pacific Polar Lows has been constructed. This derived climatology is consistent with the limited observational evidence in terms of frequency and spatial distribution. The climatology exhibits strong year-to-year variability but weak decadal variability and a small positive trend. A canonical correlation analysis describes the conditioning of the formation of Polar Lows by characteristic seasonal mean flow regimes, which favor, or limit, cold air outbreaks and upper air troughs.

  15. [Outbreaks of viral hepatitis E in the Czech Republic?].

    Science.gov (United States)

    Trmal, Josef; Pavlík, Ivo; Vasícková, Petra; Matejícková, Ladislava; Simůnková, Lenka; Luks, Stanislav; Pazderková, Jana

    2012-05-01

    Until recently, viral hepatitis E (VHE) has typically been an imported infection, related to travel to developing countries. A number of travel-unrelated VHE cases currently diagnosed in the Czech Republic. Outcomes of the epidemiological investigations of two VHE outbreaks associated with the consumption of pork and pork products at pig-slaughtering feasts are presented. Thirteen cases have been reported in the first outbreak and eight cases in the second outbreak. The epidemiological investigations are described and the experience gained in analysing suspected biological specimens is presented. The source of infection has not been identified in the first outbreak while in the other one, a link between human cases and infection in farm pigs was revealed for the first time. Although the epidemiological investigation may not always lead to the detection of the VHE source, it must be conducted in any outbreak and can only be successful when done in cooperation of the public health authorities with the veterinary health agency.

  16. Ebola Outbreak Containment: Real-Time Task and Resource Coordination With SORMAS

    Directory of Open Access Journals (Sweden)

    Cindy Perscheid

    2018-04-01

    Full Text Available Background: Since the beginning of the Ebola outbreak in West Africa in 2014, more than 11,000 people died. For outbreaks of infectious diseases like this, the rapid implementation of control measures is a crucial factor for containment. In West African countries, outbreak surveillance is a paper-based process with significant delays in forwarding outbreak information, which affects the ability to react adequately to situational changes. Our objective therefore was to develop a tool that improves data collection, situation assessment, and coordination of response measures in outbreak surveillance processes for a better containment.Methods: We have developed the Surveillance and Outbreak Response Management System (SORMAS based on findings from Nigeria's 2014 Ebola outbreak. We conducted a thorough requirements engineering and defined personas and processes. We also defined a data schema with specific variables to measure in outbreak situations. We designed our system to be a cloud application that consists of interfaces for both mobile devices and desktop computers to support all stakeholders in the process. In the field, health workers collect data on the outbreak situation via mobile applications and directly transmit it to control centers. At the control centers, health workers access SORMAS via desktop computers, receive instant updates on critical situations, react immediately on emergencies, and coordinate the implementation of control measures with SORMAS.Results: We have tested SORMAS in multiple workshops and a field study in July 2015. Results from workshops confirmed derived requirements and implemented features, but also led to further iterations on the systems regarding usability. Results from the field study are currently under assessment. General feedback showed high enthusiasm about the system and stressed its benefits for an effective outbreak containment of infectious diseases.Conclusions: SORMAS is a software tool to support

  17. Whole-body cryotherapy (extreme cold air exposure) for preventing and treating muscle soreness after exercise in adults.

    Science.gov (United States)

    Costello, Joseph T; Baker, Philip R A; Minett, Geoffrey M; Bieuzen, Francois; Stewart, Ian B; Bleakley, Chris

    2015-09-18

    Recovery strategies are often used with the intention of preventing or minimising muscle soreness after exercise. Whole-body cryotherapy, which involves a single or repeated exposure(s) to extremely cold dry air (below -100 °C) in a specialised chamber or cabin for two to four minutes per exposure, is currently being advocated as an effective intervention to reduce muscle soreness after exercise. To assess the effects (benefits and harms) of whole-body cryotherapy (extreme cold air exposure) for preventing and treating muscle soreness after exercise in adults. We searched the Cochrane Bone, Joint and Muscle Trauma Group Specialised Register, the Cochrane Central Register of Controlled Trials, MEDLINE, EMBASE, CINAHL, the British Nursing Index and the Physiotherapy Evidence Database. We also searched the reference lists of articles, trial registers and conference proceedings, handsearched journals and contacted experts.The searches were run in August 2015. We aimed to include randomised and quasi-randomised trials that compared the use of whole-body cryotherapy (WBC) versus a passive or control intervention (rest, no treatment or placebo treatment) or active interventions including cold or contrast water immersion, active recovery and infrared therapy for preventing or treating muscle soreness after exercise in adults. We also aimed to include randomised trials that compared different durations or dosages of WBC. Our prespecified primary outcomes were muscle soreness, subjective recovery (e.g. tiredness, well-being) and adverse effects. Two review authors independently screened search results, selected studies, assessed risk of bias and extracted and cross-checked data. Where appropriate, we pooled results of comparable trials. The random-effects model was used for pooling where there was substantial heterogeneity. We assessed the quality of the evidence using GRADE. Four laboratory-based randomised controlled trials were included. These reported results for 64

  18. Cold acclimation increases cold tolerance independently of diapause programing in the bean bug, Riptortus pedestris.

    Science.gov (United States)

    Rozsypal, J; Moos, M; Goto, S G

    2017-10-17

    The bean bug (Riptortus pedestris) is a pest of soybeans and other legumes in Japan and other Asian countries. It enters a facultative adult diapause on exposure to short days. While photoperiodism and diapause are well understood in R. pedestris, knowledge of cold tolerance is very limited, as is information on the effect of diapause on cold tolerance. We examined the effect of photoperiod, cold acclimation, and feeding status on cold tolerance in R. pedestris. We found that cold acclimation significantly increased survival at -10°C in both long- and short-day adult R. pedestris. Since the difference in cold survival between long- and short-day cold-acclimated groups was only marginal, we conclude that entering diapause is not crucial for R. pedestris to successfully pass through cold acclimation and become cold tolerant. We observed similar effects in 5th instar nymphs, with both long- and short-day cold-acclimated groups surviving longer cold exposures compared with non-acclimated groups. Starvation, which was tested only in adult bugs, had only a negligible and negative impact on cold survival. Although cold tolerance significantly increased with cold acclimation in adult bugs, supercooling capacity unexpectedly decreased. Our results suggest that changes in supercooling capacity as well as in water content are unrelated to cold tolerance in R. pedestris. An analysis of metabolites revealed differences between the treatments, and while several metabolites markedly increased with cold acclimation, their concentrations were too low to have a significant effect on cold tolerance.

  19. Feasibility study on novel room air conditioner with natural cooling capability

    International Nuclear Information System (INIS)

    Han, Zongwei; Liu, Qiankun; Zhang, Yanqing; Zhang, Shuwei; Liu, Jiangzhen; Li, Weiliang

    2016-01-01

    Highlights: • A novel heat pipe combined evaporative cooling room air conditioner is constructed. • The mathematical model of the air conditioner is established. • The reliability of the model is verified by experiments. • The performance of the novel and conventional air conditioner is compared. • The applicability of the novel air conditioner in different areas is investigated. - Abstract: In order to improve the energy efficiency of room air conditioners, this paper proposed a new air conditioner that combined evaporative cooling technology, separate type heat pipe technology, and vapour compression refrigeration technology (called “combined air conditioner”). The mathematical model of the air conditioner was established and its reliability was verified by experiments. Based on the model, the simulation of the operating performance of the combined air conditioner and a conventional air conditioner was studied in typical climate regions during the cooling period, with the following results: In cold and dry areas like Shenyang, compared with the conventional air conditioner, the average cooling coefficient of performance (COP) of the combined air conditioner was increased by 27.40%. As the climate gradually became warmer and humidity gradually increased, the running time of the heat pipe cooling mode was gradually reduced, and then the energy-saving effect of the combined air conditioner became worse. For example, in the hot and humid Guangzhou, the energy saving rate was only 11.81%. Therefore, it was found that the combined air conditioner had good energy-saving potential in cold and dry areas.

  20. Survey of Indoor Air Quality in the University of Alaska

    DEFF Research Database (Denmark)

    Kotol, Martin; Craven, Colin; Rode, Carsten

    2014-01-01

    problem which is poor indoor air quality (IAQ). During summer 2012 four student homes were built in Fairbanks, Alaska as a part of Sustainable Village project. The aim of this project is to promote sustainable ways of living in the Arctic and to study new technologies and their applicability in the cold......In cold climates living inside the heated space requires considerable amounts of heat. With the intention to decrease the heating demand, people are insulating their homes and make them more air tight. With the natural infiltration being brought close to zero there has been an increase of a new...... north. This paper presents the results of an IAQ survey performed in the homes during two weeks in December 2012. During this survey the air temperature, relative humidity (RH) and CO2 concentration were measured in all occupied bedrooms along with monitoring of the ventilation units. The results have...

  1. Cold-Sprayed AZ91D Coating and SiC/AZ91D Composite Coatings

    Directory of Open Access Journals (Sweden)

    Yingying Wang

    2018-03-01

    Full Text Available As an emerging coating building technique, cold spraying has many advantages to elaborate Mg alloy workpieces. In this study, AZ91D coatings and AZ91D-based composite coatings were deposited using cold spraying. Coatings were prepared using different gas temperatures to obtain the available main gas temperature. Compressed air was used as the accelerating gas, and although magnesium alloy is oxidation-sensitive, AZ91D coatings with good performance were obtained. The results show that dense coatings can be fabricated until the gas temperature is higher than 500 °C. The deposition efficiency increases greatly with the gas temperature, but it is lower than 10% for all coating specimens. To analyze the effects of compressed air on AZ91D powder particles and the effects of gas temperature on coatings, the phase composition, porosity, cross-sectional microstructure, and microhardness of coatings were characterized. X-ray diffraction and oxygen content analysis clarified that no phase transformation or oxidation occurred on AZ91D powder particles during cold spraying processes with compressed air. The porosity of AZ91D coatings remained between 3.6% and 3.9%. Impact melting was found on deformed AZ91D particles when the gas temperature increased to 550 °C. As-sprayed coatings exhibit much higher microhardness than as-casted bulk magnesium, demonstrating the dense structure of cold-sprayed coatings. To study the effects of ceramic particles on cold-sprayed AZ91D coatings, 15 vol % SiC powder particles were added into the feedstock powder. Lower SiC content in the coating than in the feedstock powder means that the deposition efficiency of the SiC powder particles is lower than the deposition efficiency of AZ91D particles. The addition of SiC particles reduces the porosity and increases the microhardness of cold-sprayed AZ91D coatings. The corrosion behavior of AZ91D coating and SiC reinforced AZ91D composite coating were examined. The Si

  2. Human angiostrongyliasis outbreak in Dali, China.

    Science.gov (United States)

    Lv, Shan; Zhang, Yi; Chen, Shao-Rong; Wang, Li-Bo; Fang, Wen; Chen, Feng; Jiang, Jin-Yong; Li, Yuan-Lin; Du, Zun-Wei; Zhou, Xiao-Nong

    2009-09-22

    Several angiostrongyliasis outbreaks have been reported in recent years but the disease continues to be neglected in public health circles. We describe an outbreak in Dali, southwest China in order to highlight some key problems for the control of this helminth infection. All available medical records of suspected angiostrongyliasis patients visiting hospitals in Dali in the period 1 October 2007-31 March 2008 were reviewed, and tentative diagnoses of varying strengths were reached according to given sets of criteria. Snails collected from local markets, restaurants and natural habitats were also screened for the presence of Angiostrongylus cantonensis. A total of 33 patients met criteria for infection, and 11 among them were classified as clinically confirmed. An additional eight patients were identified through a surveillance system put in operation in response to the outbreak. The epidemic lasted for 8 months with its peak in February 2008. Of the 33 patients, 97.0% complained of severe headache. 84.8% patients had high eosinophil cell counts either in the peripheral blood or in cerebrospinal fluid (CSF). Three-quarters of the patients were treated with a combination of albendazole and corticosteroids, resulting in significantly improved overall conditions. Twenty-two patients reported the consumption of raw or undercooked snails prior to the onset of the symptoms, and approximately 1.0% of the Pomacea canaliculata snails on sale were found to be infected with A. cantonensis. The snails were also found in certain habitats around Dali but no parasites were detected in these populations. The import and sale of infected P. canaliculata is the likely trigger for this angiostrongyliasis outbreak. Awareness of angiostrongyliasis must be raised, and standardized diagnosis and treatment are needed in order to provide clinicians with a guide to address this disease. Health education campaigns could limit the risk, and a hospital-based surveillance system should be

  3. Remediation of petroleum contaminated soils through bioventing in cold regions

    International Nuclear Information System (INIS)

    Brar, G.S.; Currier, P.M.; Reynolds, C.M.; Millhouse, J.B.

    1994-01-01

    Petroleum contaminated soils are found in many remote sites in Alaska where releases from bulk storage of fuel oil for heat and power generation have occurred. Bioventing, a process in which petroleum degradation by indigenous aerobic bacteria is enhanced by supplying oxygen and nutrients, may be a viable treatment technique for soils at remote sites if limitations due to low temperatures can be overcome. The objectives of this study were to: (1) test a design for ex-situ bioventing in cold regions, (2) evaluate biodegradation rates at low temperatures, and (3) determine the effects of applied nutrients on low-temperature biodegradation. Two aerated biopit remediation cells were constructed to treat previously excavated soils at Eareckson Air Force Station, Shemya, Alaska. Experimental treatments consisted of a fertilized pile (FP) and a nonfertilized pile (NFP). Hourly soil and air temperature data at 4 depths were recorded at 4 locations in each biopit. During 148 days of remediation, mean temperature ranged from -3 to 6 C for air at 100 cm. above the piles. The mean concentrations of TPH and DRO decreased from an initial 1,304 and 982 mg/kg of 139 and 82 mg/kg, respectively, with the FP, and 422 and 294 mg/kg with the NFP in 115 days. Cumulative degradation rates of TPH and DRO are significantly (P 2 = 0.94 for TPH. 0.93 for DRO). Pit bioventing technology was shown to be efficient, fast, and cost-effective in cold regions where temperature during winter months is a major constraint for the remediation of contaminated soils

  4. Numerical Analysis and Geometry Optimisation of Vertical Vane of Room Air-conditioner

    Directory of Open Access Journals (Sweden)

    Al-Obaidi Abdulkareem Sh. Mahdi

    2018-01-01

    Full Text Available Vertical vanes of room air-conditioners are used to control and direct cold air. This paper aims to study vertical vane as one of the parameters that affect the efficiency of dissipating cold air to a given space. The vertical vane geometry is analysed and optimised for lower production cost using CFD. The optimised geometry of the vertical vane should have the same or increased efficiency of dissipating cold air and have lesser mass compared to the existing original design. The existing original design of vertical vane is simplified and analysed by using ANSYS Fluent. Efficiency of wind direction is define as how accurate the direction of airflow coming out from vertical vane. In order to calculate the efficiency of wind direction, 15° and 30° rotation of vertical vane inside room air-conditioner are simulated. The efficiency of wind direction for 15° rotation of vertical vane is 57.81% while efficiency of wind direction for 30° rotation of vertical vane is 47.54%. The results of the efficiency of wind direction are used as base reference for parametric study. The parameters investigated for optimisation of vertical vane are focused at length of long span, tip chord and short span. The design of 15% decreased in vane surface area at tip chord is the best optimised design of vertical vane because the efficiency of wind direction is the highest as 60.32%.

  5. Building test data from real outbreaks for evaluating detection algorithms.

    Science.gov (United States)

    Texier, Gaetan; Jackson, Michael L; Siwe, Leonel; Meynard, Jean-Baptiste; Deparis, Xavier; Chaudet, Herve

    2017-01-01

    Benchmarking surveillance systems requires realistic simulations of disease outbreaks. However, obtaining these data in sufficient quantity, with a realistic shape and covering a sufficient range of agents, size and duration, is known to be very difficult. The dataset of outbreak signals generated should reflect the likely distribution of authentic situations faced by the surveillance system, including very unlikely outbreak signals. We propose and evaluate a new approach based on the use of historical outbreak data to simulate tailored outbreak signals. The method relies on a homothetic transformation of the historical distribution followed by resampling processes (Binomial, Inverse Transform Sampling Method-ITSM, Metropolis-Hasting Random Walk, Metropolis-Hasting Independent, Gibbs Sampler, Hybrid Gibbs Sampler). We carried out an analysis to identify the most important input parameters for simulation quality and to evaluate performance for each of the resampling algorithms. Our analysis confirms the influence of the type of algorithm used and simulation parameters (i.e. days, number of cases, outbreak shape, overall scale factor) on the results. We show that, regardless of the outbreaks, algorithms and metrics chosen for the evaluation, simulation quality decreased with the increase in the number of days simulated and increased with the number of cases simulated. Simulating outbreaks with fewer cases than days of duration (i.e. overall scale factor less than 1) resulted in an important loss of information during the simulation. We found that Gibbs sampling with a shrinkage procedure provides a good balance between accuracy and data dependency. If dependency is of little importance, binomial and ITSM methods are accurate. Given the constraint of keeping the simulation within a range of plausible epidemiological curves faced by the surveillance system, our study confirms that our approach can be used to generate a large spectrum of outbreak signals.

  6. Building test data from real outbreaks for evaluating detection algorithms.

    Directory of Open Access Journals (Sweden)

    Gaetan Texier

    Full Text Available Benchmarking surveillance systems requires realistic simulations of disease outbreaks. However, obtaining these data in sufficient quantity, with a realistic shape and covering a sufficient range of agents, size and duration, is known to be very difficult. The dataset of outbreak signals generated should reflect the likely distribution of authentic situations faced by the surveillance system, including very unlikely outbreak signals. We propose and evaluate a new approach based on the use of historical outbreak data to simulate tailored outbreak signals. The method relies on a homothetic transformation of the historical distribution followed by resampling processes (Binomial, Inverse Transform Sampling Method-ITSM, Metropolis-Hasting Random Walk, Metropolis-Hasting Independent, Gibbs Sampler, Hybrid Gibbs Sampler. We carried out an analysis to identify the most important input parameters for simulation quality and to evaluate performance for each of the resampling algorithms. Our analysis confirms the influence of the type of algorithm used and simulation parameters (i.e. days, number of cases, outbreak shape, overall scale factor on the results. We show that, regardless of the outbreaks, algorithms and metrics chosen for the evaluation, simulation quality decreased with the increase in the number of days simulated and increased with the number of cases simulated. Simulating outbreaks with fewer cases than days of duration (i.e. overall scale factor less than 1 resulted in an important loss of information during the simulation. We found that Gibbs sampling with a shrinkage procedure provides a good balance between accuracy and data dependency. If dependency is of little importance, binomial and ITSM methods are accurate. Given the constraint of keeping the simulation within a range of plausible epidemiological curves faced by the surveillance system, our study confirms that our approach can be used to generate a large spectrum of outbreak

  7. The Wick-Concept for Thermal Insulation of Cold Piping

    DEFF Research Database (Denmark)

    Koverdynsky, Vit; Korsgaard, Vagn; Rode, Carsten

    2006-01-01

    the wick-concept in either of two variations: the self-drying or the self-sealing system. Experiments have been carried out using different variations of the two systems to investigate the conditions for exploiting the drying capabilities of the systems, and the results are presented. The results show......The wick-concept for thermal insulation of cold piping is based on capillary suction of a fiber fabric to remove excess water from the pipe surface by transporting it to the outer surface of the insulation. From the surface of the insulation jacket, the water will evaporate to the ambient air....... This will prevent long-term accumulation of moisture in the insulation material. The wick keeps the hydrophobic insulation dry, allowing it to maintain its thermal performance. The liquid moisture is kept only in the wick fabric. This article presents the principle of operation of cold pipe insulation using...

  8. Rapid Identification of a Cooling Tower-Associated Legionnaires' Disease Outbreak Supported by Polymerase Chain Reaction Testing of Environmental Samples, New York City, 2014-2015.

    Science.gov (United States)

    Benowitz, Isaac; Fitzhenry, Robert; Boyd, Christopher; Dickinson, Michelle; Levy, Michael; Lin, Ying; Nazarian, Elizabeth; Ostrowsky, Belinda; Passaretti, Teresa; Rakeman, Jennifer; Saylors, Amy; Shamoonian, Elena; Smith, Terry-Ann; Balter, Sharon

    2018-04-01

    We investigated an outbreak of eight Legionnaires' disease cases among persons living in an urban residential community of 60,000 people. Possible environmental sources included two active cooling towers (air-conditioning units for large buildings) cooling, and potable water. To support a timely public health response, we used real-time polymerase chain reaction (PCR) to identify Legionella DNA in environmental samples within hours of specimen collection. We detected L. pneumophila serogroup 1 DNA only at a power plant cooling tower, supporting the decision to order remediation before culture results were available. An isolate from a power plant cooling tower sample was indistinguishable from a patient isolate by pulsed-field gel electrophoresis, suggesting the cooling tower was the outbreak source. PCR results were available <1 day after sample collection, and culture results were available as early as 5 days after plating. PCR is a valuable tool for identifying Legionella DNA in environmental samples in outbreak settings.

  9. Short-term associations between air pollution and respiratory drug sales

    International Nuclear Information System (INIS)

    Pitard, Alexandre; Zeghnoun, Abdelkrim; Courseaux, Annabelle; Lamberty, Jackie; Delmas, Veronique; Fossard, J.L.; Villet, Herve

    2004-01-01

    Study objective: This research was implemented to assess the effect of air pollution on anti-asthmatic, bronchodilator, and cough and cold preparation sales in the city of Rouen (France) based on the Upper Normandy Regional Union of Health Insurance Offices database and the Air Quality Monitoring Network database. Design: An ecological time-series analysis was performed for a period of 2 years (July 1998-June 2000). Generalized additive model yields to relative risks and 95% confidence interval (CI) estimates were also carried out. Main results: The 10-day cumulative effect of a 10-μg/m 3 black smoke increase was significantly associated with a 6.2% (95% CI, 2.4-10.1%) increase in the sales of anti-asthmatics and bronchodilators and to a 9.2% (95% CI, 5.9-12.6%) increase in the sales of cough and cold preparation for children aged under 15 years. The cumulative effect of a 10-μg/m 3 increase in SO 2 was associated with an 11.8% (95% CI, 6.7-17.1%) increase in cough and cold preparation sales for children aged under 15 years. The cumulative effect of 10-μg/m 3 increase in NO 2 was associated with an 13.6% (95% CI, 8-18.3%) increase in cough and cold preparation sales for children under 15 years of age. Conclusions: The results of this study suggest that an increase in drugs sales was directly related to air pollutant concentration increases in the city of Rouen (France)

  10. Food-poisoning and commercial air travel.

    Science.gov (United States)

    McMullan, R; Edwards, P J; Kelly, M J; Millar, B C; Rooney, P J; Moore, J E

    2007-09-01

    With the introduction of budget airlines and greater competitiveness amongst all airlines, air travel has now become an extremely popular form of travel, presenting its own unique set of risks from food poisoning. Foodborne illness associated with air travel is quite uncommon in the modern era. However, when it occurs, it may have serious implications for passengers and when crew are affected, has the potential to threaten safety. Quality, safe, in-flight catering relies on high standards of food preparation and storage; this applies at the airport kitchens (or at subcontractors' facilities), on the aircraft and in the transportation vehicles which carry the food from the ground source to the aircraft. This is especially challenging in certain countries. Several foodborne outbreaks have been recorded by the airline industry as a result of a number of different failures of these systems. These have provided an opportunity to learn from past mistakes and current practice has, therefore, reached such a standard so as to minimise risk of failures of this kind. This review examines: (i) the origin of food safety in modern commercial aviation; (ii) outbreaks which have occurred previously relating to aviation travel; (iii) the microbiological quality of food and water on board commercial aircraft; and (iv) how Hazard Analysis Critical Control Points may be employed to maintain food safety in aviation travel.

  11. Abnormal activity of corneal cold thermoreceptors underlies the unpleasant sensations in dry eye disease.

    Science.gov (United States)

    Kovács, Illés; Luna, Carolina; Quirce, Susana; Mizerska, Kamila; Callejo, Gerard; Riestra, Ana; Fernández-Sánchez, Laura; Meseguer, Victor M; Cuenca, Nicolás; Merayo-Lloves, Jesús; Acosta, M Carmen; Gasull, Xavier; Belmonte, Carlos; Gallar, Juana

    2016-02-01

    Dry eye disease (DED) affects >10% of the population worldwide, and it provokes an unpleasant sensation of ocular dryness, whose underlying neural mechanisms remain unknown. Removal of the main lachrymal gland in guinea pigs caused long-term reduction of basal tearing accompanied by changes in the architecture and density of subbasal corneal nerves and epithelial terminals. After 4 weeks, ongoing impulse activity and responses to cooling of corneal cold thermoreceptor endings were enhanced. Menthol (200 μM) first excited and then inactivated this augmented spontaneous and cold-evoked activity. Comparatively, corneal polymodal nociceptors of tear-deficient eyes remained silent and exhibited only a mild sensitization to acidic stimulation, whereas mechanonociceptors were not affected. Dryness-induced changes in peripheral cold thermoreceptor responsiveness developed in parallel with a progressive excitability enhancement of corneal cold trigeminal ganglion neurons, primarily due to an increase of sodium currents and a decrease of potassium currents. In corneal polymodal nociceptor neurons, sodium currents were enhanced whereas potassium currents remain unaltered. In healthy humans, exposure of the eye surface to menthol vapors or to cold air currents evoked unpleasant sensations accompanied by increased blinking frequency that we attributed to cold thermoreceptor stimulation. Notably, stimulation with menthol reduced the ongoing background discomfort of patients with DED, conceivably due to use-dependent inactivation of cold thermoreceptors. Together, these data indicate that cold thermoreceptors contribute importantly to the detection and signaling of ocular surface wetness, and develop under chronic eye dryness conditions an injury-evoked neuropathic firing that seems to underlie the unpleasant sensations experienced by patients with DED.

  12. Cold trap dehydration in the Tropical Tropopause Layer characterised by SOWER chilled-mirror hygrometer network data in the Tropical Pacific

    Directory of Open Access Journals (Sweden)

    F. Hasebe

    2013-04-01

    Full Text Available A network of balloon-borne radiosonde observations employing chilled-mirror hygrometers for water and electrochemical concentration cells for ozone has been operated since the late 1990s in the Tropical Pacific to capture the evolution of dehydration of air parcels advected quasi-horizontally in the Tropical Tropopause Layer (TTL. The analysis of this dataset is made on isentropes taking advantage of the conservative properties of tracers moving adiabatically. The existence of ice particles is diagnosed by lidars simultaneously operated with sonde flights. Characteristics of the TTL dehydration are presented on the basis of individual soundings and statistical features. Supersaturations close to 80% in relative humidity with respect to ice (RHice have been observed in subvisible cirrus clouds located near the cold point tropopause at extremely low temperatures around 180 K. Although further observational evidence is needed to confirm the credibility of such high values of RHice, the evolution of TTL dehydration is evident from the data in isentropic scatter plots between the sonde-observed mixing ratio (OMR and the minimum saturation mixing ratio (SMRmin along the back trajectories associated with the observed air mass. Supersaturation exceeding the critical value of homogeneous ice nucleation (OMR > 1.6 × SMRmin is frequently observed on the 360 and 365 K surfaces indicating that cold trap dehydration is in progress in the TTL. The near correspondence between the two (OMR ~ SMRmin at 380 K on the other hand implies that this surface is not sufficiently cold for the advected air parcels to be dehydrated. Above 380 K, cold trap dehydration would scarcely function while some moistening occurs before the air parcels reach the lowermost stratosphere at around 400 K where OMR is generally smaller than SMRmin.

  13. The highly virulent 2006 Norwegian EHEC O103:H25 outbreak strain is related to the 2011 German O104:H4 outbreak strain.

    Directory of Open Access Journals (Sweden)

    Trine M L'Abée-Lund

    Full Text Available In 2006, a severe foodborne EHEC outbreak occured in Norway. Seventeen cases were recorded and the HUS frequency was 60%. The causative strain, Esherichia coli O103:H25, is considered to be particularly virulent. Sequencing of the outbreak strain revealed resemblance to the 2011 German outbreak strain E. coli O104:H4, both in genome and Shiga toxin 2-encoding (Stx2 phage sequence. The nucleotide identity between the Stx2 phages from the Norwegian and German outbreak strains was 90%. During the 2006 outbreak, stx(2-positive O103:H25 E. coli was isolated from two patients. All the other outbreak associated isolates, including all food isolates, were stx-negative, and carried a different phage replacing the Stx2 phage. This phage was of similar size to the Stx2 phage, but had a distinctive early phage region and no stx gene. The sequence of the early region of this phage was not retrieved from the bacterial host genome, and the origin of the phage is unknown. The contaminated food most likely contained a mixture of E. coli O103:H25 cells with either one of the phages.

  14. Techno-economic evaluation for the heat integration of vaporisation cold energy in natural gas processing

    International Nuclear Information System (INIS)

    Koku, Oludolapo; Perry, Simon; Kim, Jin-Kuk

    2014-01-01

    Highlights: • Development of thermal integration modelling framework for the utilisation of LNG cold energy. • Feasibility study for various design options for the integration of low-temperature cold energy. • Provision of a design approach for achieving efficient use of cold energy in LNG terminals. • Understanding of techno-economic impacts associated with the thermal integration of LNG cold energy. - Abstract: This paper addresses a conceptual study investigating the techno-economic feasibility for the thermal Integration of LNG cold vaporisation energy in power generation applications. In conventional regasification systems, this valuable LNG cold energy is often being wasted to ambient heat sources, representing a thermodynamic inefficient process with a significant thermal impact on the local environment. A combined facility consisting of a non-integrated Combined Cycle Power Plant (CCPP) and an LNG receiving terminal employing traditional Open Rack Vaporisers (ORV) technology, has been modelled, as a base case. Retrofit strategies for the integration of LNG cold energy have been investigated, and their impacts on power production and system efficiency are systematically compared. Retrofit design options considered in this work include the use of a propane Rankine cycle coupled with the direct expansion of natural gas, the integration of a closed-loop water cycle or open-loop water circuit with a steam Rankine cycle, and the facilitation of integrated air cooling for a gas turbine

  15. Evaluation of 5 Air Criteria Pollutants; Tehran, Iran

    Directory of Open Access Journals (Sweden)

    Mazaheri Tehrani A. MSc,

    2015-09-01

    Full Text Available Aims Tehran’s uncontrolled expansion, which promoted housing, public utilities, industries and increase of vehicles caused the problem of air pollution. Necessary information about air quality in different places and different times is the first step of combating the air pollution. The purpose of this study was to investigate the annual, monthly and hourly average of 5 criteria air pollutants (PM10, O3, NO2, SO2, CO of Tehran City, Iran. Instrument & Methods The hourly concentrations of PM10, O3, NO2, SO2, CO were obtained from 21 air quality-measuring stations of Tehran City, Iran, during April 2012 to March 2013. Data were presented by descriptive statistics in the form of mean and standard deviation. Findings CO concentration was not changed during the period of study. Nitrogen dioxide increased in spring and winter. Sulfur dioxide was not changed in the first six months of the year but its concentration increased in winter. Trend of changes of floating particles showed increasing the concentration of this pollutant in May 2012 and January 2013. Ozone concentration increased in the warm seasons and decreased in the cold seasons. Conclusion PM10, O3, NO2, SO2 and CO has high concentrations and cold periods of the year are more polluted than the warm periods in Tehran City, Iran.

  16. National Outbreak Reporting System

    Data.gov (United States)

    U.S. Department of Health & Human Services — The National Outbreak Reporting System (NORS) is a web-based platform designed to support reporting to CDC by local, state, and territorial health departments in the...

  17. Detection and forecasting of oyster norovirus outbreaks: recent advances and future perspectives.

    Science.gov (United States)

    Wang, Jiao; Deng, Zhiqiang

    2012-09-01

    Norovirus is a highly infectious pathogen that is commonly found in oysters growing in fecally contaminated waters. Norovirus outbreaks can cause the closure of oyster harvesting waters and acute gastroenteritis in humans associated with consumption of contaminated raw oysters. Extensive efforts and progresses have been made in detection and forecasting of oyster norovirus outbreaks over the past decades. The main objective of this paper is to provide a literature review of methods and techniques for detecting and forecasting oyster norovirus outbreaks and thereby to identify the future directions for improving the detection and forecasting of norovirus outbreaks. It is found that (1) norovirus outbreaks display strong seasonality with the outbreak peak occurring commonly in December-March in the U.S. and April-May in the Europe; (2) norovirus outbreaks are affected by multiple environmental factors, including but not limited to precipitation, temperature, solar radiation, wind, and salinity; (3) various modeling approaches may be employed to forecast norovirus outbreaks, including Bayesian models, regression models, Artificial Neural Networks, and process-based models; and (4) diverse techniques are available for near real-time detection of norovirus outbreaks, including multiplex PCR, seminested PCR, real-time PCR, quantitative PCR, and satellite remote sensing. The findings are important to the management of oyster growing waters and to future investigations into norovirus outbreaks. It is recommended that a combined approach of sensor-assisted real time monitoring and modeling-based forecasting should be utilized for an efficient and effective detection and forecasting of norovirus outbreaks caused by consumption of contaminated oysters. Copyright © 2012 Elsevier Ltd. All rights reserved.

  18. Outbreak of Serratia marcescens in a neonatal intensive care unit: contaminated unmedicated liquid soap and risk factors.

    Science.gov (United States)

    Buffet-Bataillon, S; Rabier, V; Bétrémieux, P; Beuchée, A; Bauer, M; Pladys, P; Le Gall, E; Cormier, M; Jolivet-Gougeon, A

    2009-05-01

    This study describes an outbreak of Serratia marcescens and its investigation and control in a neonatal intensive care unit (NICU). During a three-month period, five infants were colonised or infected by a single strain of S. marcescens. A case-control study, culture surveys and pulse-field gel electrophoresis analysis implicated a bottle soap dispenser as a reservoir of S. marcescens (P=0.032). Infants with S. marcescens colonisation or infection were also more likely to have been exposed to a central or percutaneous venous catheter (P=0.05) and had had longer exposure to endotracheal intubation (P=0.05). Soap dispensers are used in many hospitals and may be an unrecognised source of nosocomial infections. This potential source of infection could be reduced by using 'airless' dispensers which have no air intake for the distribution of soap. Prompt intervention and strict adherence to alcoholic hand disinfection were the key factors that led to the successful control of this outbreak.

  19. Cold formability of steels

    International Nuclear Information System (INIS)

    Lafond, G.; Leclerq, G.; Moliexe, F.; Namdar, R.; Roesch, L.; Sanz, G.

    1977-01-01

    This work was essentially aimed to the study of the following three questions. Is it possible to assess the cold formability of steels using simple material properties as criteria. What values of mechanical properties can one expect to reach in cold formed parts. Are there simple ways of characterizing the speroidization treatments carried out on steels before cold forming operations. The present report describes the results obtained during this investigation. It is logically divided into three separate parts. Experimental study of cold formability in wire drawing. Influence of metallurgical variables on mechanical properties of high carbon cold drawn wires. Contribution to the study of characterization methods of cold forming steels subjected to a spheroidization heat treatment

  20. Swine flu - A pandemic outbreak

    Directory of Open Access Journals (Sweden)

    Jini George

    Full Text Available Hippocrates had described influenza like outbreak in 412 B.C. and since then repeated influenza like epidemics and pandemics have been recorded in recent times. One of the greatest killers of all time was the pandemic of swine flu (Spanish flu of 1918-1919, when 230 million people died. Annual influenza epidemics are estimated to affect 5–15% of the global population, resulting in severe illness in 3–5 million patients causing 250,000–500,000 deaths worldwide. Severe illness and deaths occur mainly in the high-risk populations of infants, the elderly and chronically ill patients. The 2009 outbreak of swine flu is thought to be a mutation more specifically a reassortment of four known strains of influenza A virus subtype H1N1; one endemic in humans, one endemic in birds, and two endemic in pigs. WHO officially declared the outbreak to be a pandemic on June 11, 2009, but stressed that the new designation was a result of the global "spread of the virus," not its severity. [Vet World 2009; 2(12.000: 472-474

  1. Human whole body cold adaptation.

    Science.gov (United States)

    Daanen, Hein A M; Van Marken Lichtenbelt, Wouter D

    2016-01-01

    Reviews on whole body human cold adaptation generally do not distinguish between population studies and dedicated acclimation studies, leading to confusing results. Population studies show that indigenous black Africans have reduced shivering thermogenesis in the cold and poor cold induced vasodilation in fingers and toes compared to Caucasians and Inuit. About 40,000 y after humans left Africa, natives in cold terrestrial areas seems to have developed not only behavioral adaptations, but also physiological adaptations to cold. Dedicated studies show that repeated whole body exposure of individual volunteers, mainly Caucasians, to severe cold results in reduced cold sensation but no major physiological changes. Repeated cold water immersion seems to slightly reduce metabolic heat production, while repeated exposure to milder cold conditions shows some increase in metabolic heat production, in particular non-shivering thermogenesis. In conclusion, human cold adaptation in the form of increased metabolism and insulation seems to have occurred during recent evolution in populations, but cannot be developed during a lifetime in cold conditions as encountered in temperate and arctic regions. Therefore, we mainly depend on our behavioral skills to live in and survive the cold.

  2. Additional value of typing Noroviruses in gastroenteritis outbreaks in Amsterdam, The Netherlands.

    Science.gov (United States)

    Koek, A G; Bovée, L P M J; van den Hoek, J A R; Bos, A J; Bruisten, S M

    2006-02-01

    In Amsterdam, 17 of the 55 gastroenteritis (GI) outbreaks reported from January 2002 to May 2003 were confirmed to be caused by noroviruses (NV). In this study, we describe the molecular epidemiology of a group of nine outbreaks associated with a catering firm and two outbreaks, 5 months apart, in an Amsterdam hospital. All outbreaks were typed to confirm their linkage, and the hospital-related cases were studied to see if the two outbreaks were caused by one persisting NV strain or by a reintroduction after 5 months. For the outbreaks associated with the catering firm one NV genogroup I strain was found which was identical in sequence among customers and employees of the caterer. This was not the strain that predominantly circulated in 2002/2003 in and around Amsterdam, which was the NV genogroup II4 "new variant" (GgII4nv) strain. In the Amsterdam hospital, the two outbreaks were caused by this predominant GgII4nv type, and we argue that NV was most likely reintroduced in the second outbreak from the Amsterdam community.

  3. Global malaria connectivity through air travel

    OpenAIRE

    Huang, Zhuojie; Tatem, Andrew J

    2013-01-01

    Background Air travel has expanded at an unprecedented rate and continues to do so. Its effects have been seen on malaria in rates of imported cases, local outbreaks in non-endemic areas and the global spread of drug resistance. With elimination and global eradication back on the agenda, changing levels and compositions of imported malaria in malaria-free countries, and the threat of artemisinin resistance spreading from Southeast Asia, there is a need to better understand how the modern flow...

  4. Mitigating measles outbreaks in West Africa post-Ebola.

    Science.gov (United States)

    Truelove, Shaun A; Moss, William J; Lessler, Justin

    2015-01-01

    The Ebola outbreak in 2014-2015 devastated the populations, economies and healthcare systems of Guinea, Liberia and Sierra Leone. With this devastation comes the impending threat of outbreaks of other infectious diseases like measles. Strategies for mitigating these risks must include both prevention, through vaccination, and case detection and management, focused on surveillance, diagnosis and appropriate clinical care and case management. With the high transmissibility of measles virus, small-scale reactive vaccinations will be essential to extinguish focal outbreaks, while national vaccination campaigns are needed to guarantee vaccination coverage targets are reached in the long term. Rapid and multifaceted strategies should carefully navigate challenges present in the wake of Ebola, while also taking advantage of current Ebola-related activities and international attention. Above all, resources and focus currently aimed at these countries must be utilized to build up the deficit in infrastructure and healthcare systems that contributed to the extent of the Ebola outbreak.

  5. Air pollution episodes associated with East Asian winter monsoons

    Energy Technology Data Exchange (ETDEWEB)

    Hien, P.D., E-mail: pdhien@gmail.com [Vietnam Atomic Energy Agency, 59 Ly Thuong Kiet str. Hanoi (Viet Nam); Loc, P.D.; Dao, N.V. [National Hydro-Meteorological Center, 62-A2 Nguyen Chi Thanh str. Hanoi (Viet Nam)

    2011-11-01

    A dozen multi-day pollution episodes occur from October to February in Hanoi, Vietnam due to prolonged anticyclonic conditions established after the northeast monsoon surges (cold surges). These winter pollution episodes (WPEs) account for most of the 24-h PM{sub 10} exceedances and the highest concentrations of gaseous pollutants in Hanoi. In this study, WPEs were investigated using continuous air quality monitoring data and information on upper-air soundings and air mass trajectories. The 24-h pollutant concentrations are lowest during cold surges; concurrently rise thereafter reaching the highest levels toward the middle of a monsoon cycle, then decline ahead of the next cold surge. Each monsoon cycle usually proceeds through a dry phase and a humid phase as Asiatic continental cold air arrives in Hanoi through inland China then via the East China Sea. WPEs are associated with nighttime radiation temperature inversions (NRTIs) in the dry phase and subsidence temperature inversions (STIs) in the humid phase. In NRTI periods, the rush hour pollution peak is more pronounced in the evening than in the morning and the pollution level is about two times higher at night than in daytime. In STI periods, broad morning and evening traffic peaks are observed and pollution is as high at night as in daytime. The close association between pollution and winter monsoon meteorology found in this study for the winter 2003-04 may serve as a basis for advance warning of WPEs and for forecasting the 24-h pollutant concentrations. - Highlights: {yields} Dozen pollution episodes from Oct. to Feb in Hanoi associated with anticyclones after monsoon surges. {yields} 24-h concentrations of PM{sub 10}, SO{sub 2}, NO{sub 2}, CO rise after surge and decline ahead of the next. {yields} Episodes caused by nighttime radiation and subsidence inversions in dry and humid monsoon phases. {yields} Distinct diurnal variations of pollutant concentrations observed in the two periods. {yields} Close

  6. Surveillance for waterborne disease outbreaks associated with drinking water---United States, 2007--2008.

    Science.gov (United States)

    Brunkard, Joan M; Ailes, Elizabeth; Roberts, Virginia A; Hill, Vincent; Hilborn, Elizabeth D; Craun, Gunther F; Rajasingham, Anu; Kahler, Amy; Garrison, Laurel; Hicks, Lauri; Carpenter, Joe; Wade, Timothy J; Beach, Michael J; Yoder Msw, Jonathan S

    2011-09-23

    Since 1971, CDC, the Environmental Protection Agency (EPA), and the Council of State and Territorial Epidemiologists have collaborated on the Waterborne Disease and Outbreak Surveillance System (WBDOSS) for collecting and reporting data related to occurrences and causes of waterborne disease outbreaks associated with drinking water. This surveillance system is the primary source of data concerning the scope and health effects of waterborne disease outbreaks in the United States. Data presented summarize 48 outbreaks that occurred during January 2007--December 2008 and 70 previously unreported outbreaks. WBDOSS includes data on outbreaks associated with drinking water, recreational water, water not intended for drinking (WNID) (excluding recreational water), and water use of unknown intent (WUI). Public health agencies in the states, U.S. territories, localities, and Freely Associated States are primarily responsible for detecting and investigating outbreaks and reporting them voluntarily to CDC by a standard form. Only data on outbreaks associated with drinking water, WNID (excluding recreational water), and WUI are summarized in this report. Outbreaks associated with recreational water are reported separately. A total of 24 states and Puerto Rico reported 48 outbreaks that occurred during 2007--2008. Of these 48 outbreaks, 36 were associated with drinking water, eight with WNID, and four with WUI. The 36 drinking water--associated outbreaks caused illness among at least 4,128 persons and were linked to three deaths. Etiologic agents were identified in 32 (88.9%) of the 36 drinking water--associated outbreaks; 21 (58.3%) outbreaks were associated with bacteria, five (13.9%) with viruses, three (8.3%) with parasites, one (2.8%) with a chemical, one (2.8%) with both bacteria and viruses, and one (2.8%) with both bacteria and parasites. Four outbreaks (11.1%) had unidentified etiologies. Of the 36 drinking water--associated outbreaks, 22 (61.1%) were outbreaks of

  7. The impact of cold spells on mortality and effect modification by cold spell characteristics

    Science.gov (United States)

    Wang, Lijun; Liu, Tao; Hu, Mengjue; Zeng, Weilin; Zhang, Yonghui; Rutherford, Shannon; Lin, Hualiang; Xiao, Jianpeng; Yin, Peng; Liu, Jiangmei; Chu, Cordia; Tong, Shilu; Ma, Wenjun; Zhou, Maigeng

    2016-12-01

    In China, the health impact of cold weather has received little attention, which limits our understanding of the health impacts of climate change. We collected daily mortality and meteorological data in 66 communities across China from 2006 to 2011. Within each community, we estimated the effect of cold spell exposure on mortality using a Distributed Lag Nonlinear Model (DLNM). We also examined the modification effect of cold spell characteristics (intensity, duration, and timing) and individual-specific factors (causes of death, age, gender and education). Meta-analysis method was finally used to estimate the overall effects. The overall cumulative excess risk (CER) of non-accidental mortality during cold spell days was 28.2% (95% CI: 21.4%, 35.3%) compared with non-cold spell days. There was a significant increase in mortality when the cold spell duration and intensity increased or occurred earlier in the season. Cold spell effects and effect modification by cold spell characteristics were more pronounced in south China. The elderly, people with low education level and those with respiratory diseases were generally more vulnerable to cold spells. Cold spells statistically significantly increase mortality risk in China, with greater effects in southern China. This effect is modified by cold spell characteristics and individual-level factors.

  8. CUTTING THE CORD: SUSTAINING UNTETHERED AIR SUPERIORITY OPERATIONS IN THE PACIFIC

    Science.gov (United States)

    2016-06-01

    AU/ACSC/2016 AIR COMMAND AND STAFF COLLEGE AIR UNIVERSITY CUTTING THE CORD: SUSTAINING UNTETHERED AIR SUPERIORITY OPERATIONS IN THE PACIFIC...advanced their weapons systems may be. Since the end of the Cold War, the USAF has generated sorties from main operating bases ( MOB ) in support of...Operations Desert Storm, Allied Force, Enduring Freedom, and Iraqi Freedom. MOBs in rear sanctuaries allow aircraft to operate safely from enemy attack

  9. Magnesium-Nickel alloy for hydrogen storage produced by melt spinning followed by cold rolling

    Directory of Open Access Journals (Sweden)

    Daniel Rodrigo Leiva

    2012-10-01

    Full Text Available Severe plastic deformation routes (SPD have been shown to be attractive for short time preparation of magnesium alloys for hydrogen storage, generating refined microstructures and interesting hydrogen storage properties when compared to the same materials processed by high-energy ball milling (HEBM, but with the benefit of higher air resistance. In this study, we present results of a new processing route for Mg alloys for hydrogen storage: rapid solidification followed by cold work. A Mg97Ni3 alloy was processed by melt spinning (MS and by extensive cold rolling (CR. Submitting Mg97Ni3 ribbons between steel plates to cold rolling has shown to be a viable procedure, producing a thin cold welded foil, with little material waste. The as-processed material presents a high level of [002] fiber texture, a sub microcrystalline grain structure with a high density of defects, and also a fine dispersion of Mg2Ni nanoparticles. This refined microstructure allied to the developed texture resulted in enhanced activation and H-sorption kinetics properties.

  10. The accelerating effects of the microorganisms on biodeterioration of stone monuments under air pollution and continental-cold climatic conditions in Erzurum, Turkey

    International Nuclear Information System (INIS)

    Nuhoglu, Y.; Oguz, E.; Uslu, H.; Ozbek, A.; Ipekoglu, B.; Ocak, I.; Hasenekoglu, I.

    2006-01-01

    The aim of this research was to determine the accelerating effects of microorganisms on the biodeterioration of stone under air pollution and continental-cold climatic region in Erzurum, Turkey. Studies have been carried out on specimens of the Rustempasa Bazaar, the Lalapasa Mosque, the Erzurum Castle Mosque, the Double Minarets-Madrasah, the Great Mosque and the Haji Mehmet Fountain aged from 441 to 823 years old. The results showed that vegetative and reproductive (generative) forms of the microorganisms could develop during the winter months when the night time average temperature was even - 25 deg. C. Also the reproductive forms had developed and the whole stone surface was covered with a biofilm caused by the microorganisms. Silicon, aluminum, calcium, potassium, titanium, magnesium, zinc, sulfur, iron, sodium, and niobium were found in the stones of the historical buildings with varying amounts through the SEM-EDS analysis. Some of these elements could be used as an energy resource for the microorganisms together with the air pollutants such as sulfur dioxide, nitrogen oxides and particles on the stone surfaces. Of 21 isolates, 15 species from 6 bacterium genera and 5 species from 5 fungi genera plus 1 fungi genera were identified on the deteriorated stone surfaces even during the coldest months by microbial identification system (MIS) and these findings were tested by SEM investigations

  11. Legionnaires' Disease Outbreaks and Cooling Towers, New York City, New York, USA.

    Science.gov (United States)

    Fitzhenry, Robert; Weiss, Don; Cimini, Dan; Balter, Sharon; Boyd, Christopher; Alleyne, Lisa; Stewart, Renee; McIntosh, Natasha; Econome, Andrea; Lin, Ying; Rubinstein, Inessa; Passaretti, Teresa; Kidney, Anna; Lapierre, Pascal; Kass, Daniel; Varma, Jay K

    2017-11-01

    The incidence of Legionnaires' disease in the United States has been increasing since 2000. Outbreaks and clusters are associated with decorative, recreational, domestic, and industrial water systems, with the largest outbreaks being caused by cooling towers. Since 2006, 6 community-associated Legionnaires' disease outbreaks have occurred in New York City, resulting in 213 cases and 18 deaths. Three outbreaks occurred in 2015, including the largest on record (138 cases). Three outbreaks were linked to cooling towers by molecular comparison of human and environmental Legionella isolates, and the sources for the other 3 outbreaks were undetermined. The evolution of investigation methods and lessons learned from these outbreaks prompted enactment of a new comprehensive law governing the operation and maintenance of New York City cooling towers. Ongoing surveillance and program evaluation will determine if enforcement of the new cooling tower law reduces Legionnaires' disease incidence in New York City.

  12. Effect of fast freeze-thaw cycles on mechanical properties of ordinary-air-entrained concrete.

    Science.gov (United States)

    Shang, Huai-shuai; Cao, Wei-qun; Wang, Bin

    2014-01-01

    Freezing-thawing resistance is a very significant characteristic for concrete in severe environment (such as cold region with the lowest temperature below 0°C). In this study, ordinary-air-entrained (O-A-E) concrete was produced in a laboratory environment; the compressive strength, cubic compressive strength of C50, C40, C30, C25, and C20 ordinary-air-entrained concrete, tensile strength, and cleavage strength of C30 ordinary-air-entrained concrete were measured after fast freeze-thaw cycles. The effects of fast freeze-thaw cycles on the mechanical properties (compressive strength and cleavage strength) of ordinary-air-entrained concrete materials are investigated on the basis of the experimental results. And the concise mathematical formula between mechanical behavior and number of fast freeze-thaw cycles was established. The experiment results can be used as a reference in design, maintenance, and life prediction of ordinary-air-entrained concrete structure (such as dam, offshore platform, etc.) in cold regions.

  13. Diesel CPO for SOFC. Development of a cold-flame assisted CPO reactor coupled to a SOFC

    Energy Technology Data Exchange (ETDEWEB)

    Van Dijk, H.A.J.; Ouweltjes, J.P.; Nyqvist, R.G. [ECN Hydrogen and Clean Fossil Fuels, Petten (Netherlands)

    2009-07-15

    Within the research program 'Reforming of liquid fuels for fuel-cells', ECN started a project on the development of a diesel CPO (catalytic partial oxidation) reformer for SOFC (solid oxide fuel cell) in 2005. The application in mind is a small scale (5kWe) diesel fed auxiliary power unit (APU). The goal of the project is to develop the technology required to transform a liquid logistic fuel into a reformat suitable for the operation of a SOFC. The emphasis of this work is on the development of a cold-flame assisted evaporator/mixer coupled to a catalytic CPO reformer. The application of cold-flame evaporation and mixing allows the reformat to be directly fed to the SOFC without further heating or cooling. Moreover, once cold-flames are ignited and stabilized, pre-heating of the air and fuel becomes obsolete. These aspects justify the development described in this report. In the cold-flame evaporator/mixer, the cold-flames are stabilized by means of a recirculation tube. The momentum of the fuel spray of the nozzle induces the required recirculation. The cold flame evaporator/mixer was coupled to a catalytic reformer reactor, transforming the hydrocarbon+air feed into a CO+H2 rich reformate. The reformer was coupled to a SOFC to be able to verify the quality of the reformat obtained with this reformer. The SOFC therefore served as an analysis tool. Characteristically, the reformat was held at 800C all the way towards the SOFC. For this, high temperature flange connections and steel-ceramic expansion connections were successfully applied. It is demonstrated that cold-flame evaporation of liquid fuels is a feasible means of feed preparation for a catalytic reforming reactor. The quality of the resulting reformat is adequate to be fed to the SOFC. The reformat quality, however, decreased with time-on-stream due to fouling of the reformer by carbon-depositions. These carbon-depositions were essentially located on the fuel injector, which is the coldest part

  14. Developing a climate-based risk map of fascioliasis outbreaks in Iran

    Directory of Open Access Journals (Sweden)

    Mansour Halimi

    2015-09-01

    Full Text Available Summary: The strong relationship between climate and fascioliasis outbreaks enables the development of climate-based models to estimate the potential risk of fascioliasis outbreaks. This work aims to develop a climate-based risk map of fascioliasis outbreaks in Iran using Ollerenshaw's fascioliasis risk index incorporating geographical information system (GIS. Using this index, a risk map of fascioliasis outbreaks for the entire country was developed. We determined that the country can be divided into 4 fascioliasis outbreak risk categories. Class 1, in which the Mt value is less than 100, includes more than 0.91 of the country's area. The climate in this class is not conducive to fascioliasis outbreaks in any month. Dryness and low temperature in the wet season (December to April are the key barriers against fascioliasis outbreaks in this class. The risk map developed based on climatic factors indicated that only 0.03 of the country's area, including Gilan province in the northern region of Iran, is highly suitable to fascioliasis outbreaks during September to January. The Mt value is greater than 500 in this class. Heavy rainfall in the summer and fall, especially in Rasht, Astara and Bandar Anzaly (≥1000 mm/year, creates more suitable breeding places for snail intermediate hosts. Keywords: Ollerenshaw fascioliasis risk index, Climate, Gilan province, Iran

  15. Developing a climate-based risk map of fascioliasis outbreaks in Iran.

    Science.gov (United States)

    Halimi, Mansour; Farajzadeh, Manuchehr; Delavari, Mahdi; Arbabi, Mohsen

    2015-01-01

    The strong relationship between climate and fascioliasis outbreaks enables the development of climate-based models to estimate the potential risk of fascioliasis outbreaks. This work aims to develop a climate-based risk map of fascioliasis outbreaks in Iran using Ollerenshaw's fascioliasis risk index incorporating geographical information system (GIS). Using this index, a risk map of fascioliasis outbreaks for the entire country was developed. We determined that the country can be divided into 4 fascioliasis outbreak risk categories. Class 1, in which the Mt value is less than 100, includes more than 0.91 of the country's area. The climate in this class is not conducive to fascioliasis outbreaks in any month. Dryness and low temperature in the wet season (December to April) are the key barriers against fascioliasis outbreaks in this class. The risk map developed based on climatic factors indicated that only 0.03 of the country's area, including Gilan province in the northern region of Iran, is highly suitable to fascioliasis outbreaks during September to January. The Mt value is greater than 500 in this class. Heavy rainfall in the summer and fall, especially in Rasht, Astara and Bandar Anzaly (≥ 1000 mm/year), creates more suitable breeding places for snail intermediate hosts. Copyright © 2015 King Saud Bin Abdulaziz University for Health Sciences. Published by Elsevier Ltd. All rights reserved.

  16. Investigating Listeria Outbreaks

    Centers for Disease Control (CDC) Podcasts

    2013-01-04

    Dr. Emily Cartwright, Infectious Disease fellow at Emory University and former EIS Officer with CDC’s Division of Foodborne, Waterborne, and Environmental Diseases discusses foodborne Listeria outbreaks.  Created: 1/4/2013 by National Center for Emerging and Zoonotic Infectious Diseases (NCEZID).   Date Released: 1/8/2013.

  17. Ebola virus outbreak, updates on current therapeutic strategies.

    Science.gov (United States)

    Elshabrawy, Hatem A; Erickson, Timothy B; Prabhakar, Bellur S

    2015-07-01

    Filoviruses are enveloped negative-sense single-stranded RNA viruses, which include Ebola and Marburg viruses, known to cause hemorrhagic fever in humans with a case fatality of up to 90%. There have been several Ebola virus outbreaks since the first outbreak in the Democratic Republic of Congo in 1976 of which, the recent 2013-2015 epidemic in Guinea, Liberia, and Sierra Leone is the largest in recorded history. Within a few months of the start of the outbreak in December 2013, thousands of infected cases were reported with a significant number of deaths. As of March 2015, according to the Centers for Disease Control and Prevention, there have been nearly 25,000 suspected cases, with 15,000 confirmed by laboratory testing, and over 10,000 deaths. The large number of cases and the high mortality rate, combined with the lack of effective Food and Drug Administration-approved treatments, necessitate the development of potent and safe therapeutic measures to combat the current and future outbreaks. Since the beginning of the outbreak, there have been considerable efforts to develop and characterize protective measures including vaccines and antiviral small molecules, and some have proven effective in vitro and in animal models. Most recently, a cocktail of monoclonal antibodies has been shown to be highly effective in protecting non-human primates from Ebola virus infection. In this review, we will discuss what is known about the nature of the virus, phylogenetic classification, genomic organization and replication, disease transmission, and viral entry and highlight the current approaches and efforts, in the development of therapeutics, to control the outbreak. Copyright © 2015 John Wiley & Sons, Ltd.

  18. Societal learning in epidemics: intervention effectiveness during the 2003 SARS outbreak in Singapore.

    Directory of Open Access Journals (Sweden)

    John M Drake

    Full Text Available BACKGROUND: Rapid response to outbreaks of emerging infectious diseases is impeded by uncertain diagnoses and delayed communication. Understanding the effect of inefficient response is a potentially important contribution of epidemic theory. To develop this understanding we studied societal learning during emerging outbreaks wherein patient removal accelerates as information is gathered and disseminated. METHODS AND FINDINGS: We developed an extension of a standard outbreak model, the simple stochastic epidemic, which accounts for societal learning. We obtained expressions for the expected outbreak size and the distribution of epidemic duration. We found that rapid learning noticeably affects the final outbreak size even when learning exhibits diminishing returns (relaxation. As an example, we estimated the learning rate for the 2003 outbreak of severe acute respiratory syndrome (SARS in Singapore. Evidence for relaxation during the first eight weeks of the outbreak was inconclusive. We estimated that if societal learning had occurred at half the actual rate, the expected final size of the outbreak would have reached nearly 800 cases, more than three times the observed number of infections. By contrast, the expected outbreak size for societal learning twice as effective was 116 cases. CONCLUSION: These results show that the rate of societal learning can greatly affect the final size of disease outbreaks, justifying investment in early warning systems and attentiveness to disease outbreak by both government authorities and the public. We submit that the burden of emerging infections, including the risk of a global pandemic, could be efficiently reduced by improving procedures for rapid detection of outbreaks, alerting public health officials, and aggressively educating the public at the start of an outbreak.

  19. Cost-benefit analysis of improved air quality in an office building

    DEFF Research Database (Denmark)

    Djukanovic, R.; Wargocki, Pawel; Fanger, Povl Ole

    2002-01-01

    A cost-benefit analysis of measures to improve air quality in an existing air-conditoned office building (11581 m2, 864 employees) was carried out for hot, temperate and cold climates and for two operating modes: Variable Air Volume (VAV) with economizer; and Constant Air Volume (CAV) with heat...... recovery. The annual energy cost and first cost of the HVAC system were calculat4ed using DOE 2.1E for different levels of air quality (10-50% dissatisfied). This was achieved by changing the outdoor air supply rate and the pollution loads. Previous studies have documented a 1.1% increase in office...

  20. Retrofitting Forced Air Combi Systems: A Cold Climate Field Assessment

    Energy Technology Data Exchange (ETDEWEB)

    Schoenbauer, Ben [NorthernSTAR, St. Paul, MN (United States); Bohac, Dave [NorthernSTAR, St. Paul, MN (United States); McAlpine, Jack [NorthernSTAR, St. Paul, MN (United States); Hewett, Martha [NorthernSTAR, St. Paul, MN (United States)

    2017-06-01

    This project analyzed combined condensing water heaters or boilers and hydronic air coils to provide high efficiency domestic hot water (DHW) and forced air space heating. Called "combi" systems, they provided similar space and water heating performance less expensively than installing two condensing appliances. The system's installed costs were cheaper than installing a condensing furnace and either a condensing tankless or condensing storage water heater. However, combi costs must mature and be reduced before they are competitive with a condensing furnace and power vented water heater (energy factor of 0.60). Better insulation and tighter envelopes are reducing space heating loads for new and existing homes. For many homes, decreased space heating loads make it possible for both space and domestic water heating loads to be provided with a single heating plant. These systems can also eliminate safety issues associated with natural draft appliances through the use of one common sealed combustion vent. The combined space and water heating approach was not a new idea. Past systems have used non-condensing heating plants, which limited their usefulness in climates with high heating loads. Previous laboratory work (Schoenbauer et al. 2012a) showed that proper installation was necessary to achieve condensing with high efficiency appliances. Careful consideration was paid to proper system sizing and minimizing the water temperature returning from the air handling unit to facilitate condensing operation.

  1. Retrofitting Forced Air Combi Systems: A Cold Climate Field Assessment

    Energy Technology Data Exchange (ETDEWEB)

    Schoenbauer, Ben [Univ. of Minnesota, St. Paul, MN (United States). NorthernSTAR Building America Partnership; Bohac, Dave [Univ. of Minnesota, St. Paul, MN (United States). NorthernSTAR Building America Partnership; McAlpine, Jake [Univ. of Minnesota, St. Paul, MN (United States). NorthernSTAR Building America Partnership; Hewett, Martha [Univ. of Minnesota, St. Paul, MN (United States). NorthernSTAR Building America Partnership

    2017-06-23

    This project analyzed combined condensing water heaters or boilers and hydronic air coils to provide high efficiency domestic hot water (DHW) and forced air space heating. Called 'combi' systems, they provided similar space and water heating performance less expensively than installing two condensing appliances. The system's installed costs were cheaper than installing a condensing furnace and either a condensing tankless or condensing storage water heater. However, combi costs must mature and be reduced before they are competitive with a condensing furnace and power vented water heater (energy factor of 0.60). Better insulation and tighter envelopes are reducing space heating loads for new and existing homes. For many homes, decreased space heating loads make it possible for both space and domestic water heating loads to be provided with a single heating plant. These systems can also eliminate safety issues associated with natural draft appliances through the use of one common sealed combustion vent. The combined space and water heating approach was not a new idea. Past systems have used non-condensing heating plants, which limited their usefulness in climates with high heating loads. Previous laboratory work (Schoenbauer et al. 2012a) showed that proper installation was necessary to achieve condensing with high efficiency appliances. Careful consideration was paid to proper system sizing and minimizing the water temperature returning from the air handling unit to facilitate condensing operation.

  2. Simple visit behavior unifies complex Zika outbreaks

    Directory of Open Access Journals (Sweden)

    P.D. Manrique

    2017-12-01

    Full Text Available New outbreaks of Zika in the U.S. are imminent. Human nature dictates that many individuals will continue to revisit affected ‘Ground Zero’ patches, whether out of choice, work or family reasons − yet this feature is missing from traditional epidemiological analyses. Here we show that this missing visit-revisit mechanism is by itself capable of explaining quantitatively the 2016 human Zika outbreaks in all three Ground Zero patches. Our findings reveal counterintuitive ways in which this human flow can be managed to tailor any future outbreak’s duration, severity and time-to-peak. Effective public health planning can leverage these results to impact the evolution of future outbreaks via soft control of the overall human flow, as well as to suggest best-practice visitation behavior for local residents.

  3. An Outbreak of Foodborne Botulism in Ontario

    Directory of Open Access Journals (Sweden)

    Mona R Loutfy

    2003-01-01

    Full Text Available Botulism is a rare paralytic illness resulting from a potent neurotoxin produced by Clostridium botulinum. Botulism in Canada is predominately due to C botulinum type E and affects mainly the First Nations and Inuit populations. The most recent outbreak of botulism in Ontario was in Ottawa in 1991 and was caused by C botulinum type A. We report an outbreak of foodborne type B botulism in Ontario, which implicated home-canned tomatoes. The outbreak was characterized by mild symptoms in two cases and moderately severe illness in one case. The investigation shows the importance of considering the diagnosis of botulism in patients presenting with cranial nerve and autonomic dysfunction, especially when combined with gastrointestinal complaints; it also highlights the importance of proper home canning technique.

  4. Measles outbreaks affecting children in Jewish ultra-orthodox communities in Jerusalem

    Science.gov (United States)

    STEIN-ZAMIR, C.; ZENTNER, G.; ABRAMSON, N.; SHOOB, H.; ABOUDY, Y.; SHULMAN, L.; MENDELSON, E.

    2008-01-01

    SUMMARY In 2003 and 2004 two measles outbreaks occurred in Jewish ultra-orthodox communities in Jerusalem. The index case of the first outbreak (March 2003) was a 2-year-old unvaccinated child from Switzerland. Within 5 months, 107 cases (mean age 8·3±7·5 years) emerged in three crowded neighbourhoods. The first cases of the second outbreak (June 2004) were in three girls aged 4–5 years in one kindergarten in another community. By November 2004, 117 cases (mean age 7·3±6·5 years) occurred. The virus genotypes were D8 and D4 respectively. Altogether, 96 households accounted for the two outbreaks, with two or more patients per family in 79% of cases. Most cases (91·5%) were unvaccinated. Immunization coverage was lower in outbreak than in non-outbreak neighbourhoods (88·3% vs. 90·3%, P=0·001). Controlling the outbreaks necessitated a culture-sensitive approach, and targeted efforts increased MMR vaccine coverage (first dose) to 95·2%. Despite high national immunization coverage (94–95%), special attention to specific sub-populations is essential. PMID:17433131

  5. Outbreaks of virulent diarrheagenic Escherichia coli - are we in control?

    Directory of Open Access Journals (Sweden)

    Werber Dirk

    2012-02-01

    Full Text Available Abstract Shiga toxin-producing Escherichia coli (STEC are the most virulent diarrheagenic E. coli known to date. They can be spread with alarming ease via food as exemplified by a large sprout-borne outbreak of STEC O104:H4 in 2011 that was centered in northern Germany and affected several countries. Effective control of such outbreaks is an important public health task and necessitates early outbreak detection, fast identification of the outbreak vehicle and immediate removal of the suspected food from the market, flanked by consumer advice and measures to prevent secondary spread. In our view, opportunities to improve control of STEC outbreaks lie in early clinical suspicion for STEC infection, timely diagnosis of all STEC at the serotype-level and integrating molecular subtyping information into surveillance systems. Furthermore, conducting analytical studies that supplement patients' imperfect food history recall and performing, as an investigative element, product tracebacks, are pivotal but underutilized tools for successful epidemiologic identification of the suspected vehicle in foodborne outbreaks. As a corollary, these tools are amenable to tailor microbiological testing of suspected food. Please see related article: http://www.biomedcentral.com/1741-7015/10/12

  6. Post-earthquake outbreak of rotavirus gastroenteritis in Kashmir (India): an epidemiological analysis.

    Science.gov (United States)

    Karmakar, Somenath; Rathore, Abhilakh Singh; Kadri, Syed Manzoor; Dutt, Som; Khare, Shashi; Lal, Shiv

    2008-10-01

    An earthquake struck Kashmir on 8 October 2005. A central team of public health specialists was sent to Kashmir to assess the public health measures required following the earthquake, and to assist in institution of public health measures. Epidemiological and environmental investigation in Tangdar block (Kupwara district) and Uri Tehsil (Baramula district). Visits to villages affected by the earthquake, rehabilitation camps and health care, examination of cases with acute diarrhoeal disease (ADD), environmental observations, collection of clinical samples from ADD cases and environmental samples from drinking water sources, and laboratory methods. In total, 1783 cases of ADD were reported between 14 October and 17 December 2005 in Tangdar (population 65000). The overall attack rate was 20% in children under 4 years of age. Twelve cases of ADD with loose motions without blood were studied, and 11 rectal swabs and one stool sample were processed. No bacterial enteropathogens could be isolated, but three of the 12 samples yielded rotavirus antigen on enzyme-linked immunosorbent assay. Twelve of 13 (92.3%) water samples, collected from various stream or tap water (source: spring/stream) sources, were unsatisfactory (P=0.001) using the H(2)S strip method compared with other sources (well/mineral water). All eight water sources in Tangdar block were unsatisfactory, indicated by blackening of H(2)S filter paper strips. Following the earthquake, drinking stream water or tap water without boiling or chlorination may have led to a common source water-borne outbreak of rotavirus gastroenteritis. Other contributing factors were: overcrowding; poor sanitation; open-air defaecation; poor hygiene; and living in makeshift camps near streams. Person-to-person transmission may also have contributed to perpetuation of the outbreak. Following the establishment of medical camps and information, education and communication regarding the need to drink boiled water and follow safer

  7. Rapid Identification of a Cooling Tower-Associated Legionnaires’ Disease Outbreak Supported by Polymerase Chain Reaction Testing of Environmental Samples, New York City, 2014–2015

    Science.gov (United States)

    Benowitz, Isaac; Fitzhenry, Robert; Boyd, Christopher; Dickinson, Michelle; Levy, Michael; Lin, Ying; Nazarian, Elizabeth; Ostrowsky, Belinda; Passaretti, Teresa; Rakeman, Jennifer; Saylors, Amy; Shamoonian, Elena; Smith, Terry-Ann; Balter, Sharon

    2018-01-01

    We investigated an outbreak of eight Legionnaires’ disease cases among persons living in an urban residential community of 60,000 people. Possible environmental sources included two active cooling towers (air-conditioning units for large buildings) cooling, and potable water. To support a timely public health response, we used real-time polymerase chain reaction (PCR) to identify Legionella DNA in environmental samples within hours of specimen collection. We detected L. pneumophila serogroup 1 DNA only at a power plant cooling tower, supporting the decision to order remediation before culture results were available. An isolate from a power plant cooling tower sample was indistinguishable from a patient isolate by pulsed-field gel electrophoresis, suggesting the cooling tower was the outbreak source. PCR results were available <1 day after sample collection, and culture results were available as early as 5 days after plating. PCR is a valuable tool for identifying Legionella DNA in environmental samples in outbreak settings. PMID:29780175

  8. Chillers and cold water units. Special issue; Chillers en koudwateraggregaten. Thema

    Energy Technology Data Exchange (ETDEWEB)

    Van Zwam, P. [GEA Refrigeration Components Benelux, Den Bosch (Netherlands); Meijer, W. [Daikin Airconditioning Netherlands, Rotterdam (Netherlands); Torsy, E. [Trane Airconditioning, Soest (Netherlands); Berends, E. [GEA Grenco Refrigeration, Den Bosch (Netherlands); Havenaar, D. (ed.)

    2010-05-15

    In five articles attention is paid to several aspects of chillers and cold water units: (1) reduction of refrigerants and increase of the COP; (2) realization of high partial load efficiency in mono-screw compressors; (3) energy efficient innovation for cooling and heat pump systems; (4) application of modern chiller technology for a skating rink of Sportboulevard, Dordrecht, Netherlands; and (5) the use of propane as a refrigerant in air-cooled cold water units. [Dutch] In vijf artikelen wordt aandacht besteed aan verschillende aspecten van chillers en koudwateraggregaten: (1) minimaliseren van koudemiddeleninhoud en verhogen van de COP; (2) realisatie van hoge deellastrendementen met mono-schroefcompressoren; (3) energie efficiente innovaties voor koelmachine- en warmtepompsystemen; (4) toepassing van moderne chillertechnologie in de ijshal van Sportboulevard Dordrecht; en (5) het gebruik van propaan als koudemiddel in luchtgekoelde koudwateraggregaten.

  9. Energy Performance of a Light Wood-Timber Structured House in the Severely Cold Region of China

    Directory of Open Access Journals (Sweden)

    Meng Zhen

    2018-05-01

    Full Text Available The purpose of the study was to determine the energy performance of a timber structured house built in Harbin, a severely cold region of China. The research team conducted a field test on the house that lasted three months (15 January–15 April 2008. The test included the winter heating energy consumption, average indoor temperature and relative humidity, building heat storage capacity, heat transfer coefficient of the wall, total air volume of air-conditioning system, etc. The test results showed that the total heating was calculated to be 73,240.59 MJ in winter. Thermal imaging tests were carried out on the house and found no obvious thermal defects such as thermal bridges. In conclusion, the timber structured house has a good level of building energy conservation and would provide a good exemplary for green building design and construction in similar severely cold regions in the world.

  10. The importance of waterborne disease outbreak surveillance in the United States

    Directory of Open Access Journals (Sweden)

    Gunther Franz Craun

    2012-12-01

    Full Text Available Analyses of the causes of disease outbreaks associated with contaminated drinking water in the United States have helped inform prevention efforts at the national, state, and local levels. This article describes the changing nature of disease outbreaks in public water systems during 1971-2008 and discusses the importance of a collaborative waterborne outbreak surveillance system established in 1971. Increasing reports of outbreaks throughout the early 1980s emphasized that microbial contaminants remained a health-risk challenge for suppliers of drinking water. Outbreak investigations identified the responsible etiologic agents and deficiencies in the treatment and distribution of drinking water, especially the high risk associated with unfiltered surface water systems. Surveillance information was important in establishing an effective research program that guided government regulations and industry actions to improve drinking water quality. Recent surveillance statistics suggest that prevention efforts based on these research findings have been effective in reducing outbreak risks especially for surface water systems.

  11. Mumps outbreak in Israel's highly vaccinated society: are two doses enough?

    Science.gov (United States)

    Anis, E; Grotto, I; Moerman, L; Warshavsky, B; Slater, P E; Lev, B

    2012-03-01

    Mumps outbreaks in recent years have given rise to questions about the effectiveness of the mumps vaccine. This study examined the epidemiological data from a recent mumps outbreak in Israel and from outbreaks in other countries with high vaccination coverage, and considered whether long-established vaccination policies designed to protect against mumps are in need of revision. Of over 5000 case patients in the Israeli outbreak, half of whom were in the Jerusalem health district, nearly 40% were aged ≥15 years and, of those whose vaccination status was known, 78% had been fully vaccinated for their age - features similar to those in recent mumps outbreaks in Europe and North America. The epidemiological and laboratory evidence suggests that many previously vaccinated adolescents and young adults are now susceptible to mumps because their vaccine-based immunity has waned. Booster vaccination programmes for those at high risk of infection during mumps outbreaks - particularly those in congregate living environments - merit priority consideration.

  12. Markov Chain-Based Acute Effect Estimation of Air Pollution on Elder Asthma Hospitalization

    Directory of Open Access Journals (Sweden)

    Li Luo

    2017-01-01

    Full Text Available Background. Asthma caused substantial economic and health care burden and is susceptible to air pollution. Particularly, when it comes to elder asthma patient (older than 65, the phenomenon is more significant. The aim of this study is to investigate the Markov-based acute effects of air pollution on elder asthma hospitalizations, in forms of transition probabilities. Methods. A retrospective, population-based study design was used to assess temporal patterns in hospitalizations for asthma in a region of Sichuan province, China. Approximately 12 million residents were covered during this period. Relative risk analysis and Markov chain model were employed on daily hospitalization state estimation. Results. Among PM2.5, PM10, NO2, and SO2, only SO2 was significant. When air pollution is severe, the transition probability from a low-admission state (previous day to high-admission state (next day is 35.46%, while it is 20.08% when air pollution is mild. In particular, for female-cold subgroup, the counterparts are 30.06% and 0.01%, respectively. Conclusions. SO2 was a significant risk factor for elder asthma hospitalization. When air pollution worsened, the transition probabilities from each state to high admission states increase dramatically. This phenomenon appeared more evidently, especially in female-cold subgroup (which is in cold season for female admissions. Based on our work, admission amount forecast, asthma intervention, and corresponding healthcare allocation can be done.

  13. Quantification and assessment of heat and cold waves in Novi Sad, Northern Serbia

    Science.gov (United States)

    Basarin, Biljana; Lukić, Tin; Matzarakis, Andreas

    2016-01-01

    Physiologically equivalent temperature (PET) has been applied to the analysis of heat and cold waves and human thermal conditions in Novi Sad, Serbia. A series of daily minimum and maximum air temperature, relative humidity, wind, and cloud cover was used to calculate PET for the investigated period 1949-2012. The heat and cold wave analysis was carried out on days with PET values exceeding defined thresholds. Additionally, the acclimatization approach was introduced to evaluate human adaptation to interannual thermal perception. Trend analysis has revealed the presence of increasing trend in summer PET anomalies, number of days above defined threshold, number of heat waves, and average duration of heat waves per year since 1981. Moreover, winter PET anomaly as well as the number of days below certain threshold and number of cold waves per year until 1980 was decreasing, but the decrease was not statistically significant. The highest number of heat waves during summer was registered in the last two decades, but also in the first decade of the investigated period. On the other hand, the number of cold waves during six decades is quite similar and the differences are very small.

  14. Responding to Outbreaks

    Centers for Disease Control (CDC) Podcasts

    2009-04-27

    In this podcast, a team of CDC specialists travels to Uganda and tracks the source of an Ebola outbreak where CDC scientists are studying bats for clues to the Ebola mystery.  Created: 4/27/2009 by National Center for Zoonotic, Vector-Borne, and Enteric Diseases (NCZVED).   Date Released: 4/27/2009.

  15. Urban air pollution, poverty, violence and health--Neurological and immunological aspects as mediating factors.

    Science.gov (United States)

    Kristiansson, Marianne; Sörman, Karolina; Tekwe, Carmen; Calderón-Garcidueñas, Lilian

    2015-07-01

    Rapid rural-urban migration has created overcrowded areas characterized by concentrated poverty and increases in indoor and outdoor air pollutants. These "hotspots" constitute an increased risk of violence and disease outbreaks. We hypothesize that the effects of poverty and associated air pollution-related stress on impaired cognitive skills are mediated by inflammatory cytokines. A research framework is proposed, encompassing (i) an epidemiological investigation of associations between poverty, high concentrations of air pollutants, violence and health, (ii) a longitudinal follow-up of working memory capacities and inflammatory markers, and (iii) intervention programs aiming to strengthen employability and decreased exposures to toxic air pollutants. Copyright © 2015 Elsevier Inc. All rights reserved.

  16. Literature Review of Associations among Attributes of Reported Drinking Water Disease Outbreaks

    Directory of Open Access Journals (Sweden)

    Grant Ligon

    2016-05-01

    Full Text Available Waterborne disease outbreaks attributed to various pathogens and drinking water system characteristics have adversely affected public health worldwide throughout recorded history. Data from drinking water disease outbreak (DWDO reports of widely varying breadth and depth were synthesized to investigate associations between outbreak attributes and human health impacts. Among 1519 outbreaks described in 475 sources identified during review of the primarily peer-reviewed, English language literature, most occurred in the U.S., the U.K. and Canada (in descending order. The outbreaks are most frequently associated with pathogens of unknown etiology, groundwater and untreated systems, and catchment realm-associated deficiencies (i.e., contamination events. Relative frequencies of outbreaks by various attributes are comparable with those within other DWDO reviews, with water system size and treatment type likely driving most of the (often statistically-significant at p < 0.05 differences in outbreak frequency, case count and attack rate. Temporal analysis suggests that while implementation of surface (drinking water management policies is associated with decreased disease burden, further strengthening of related policies is needed to address the remaining burden attributed to catchment and distribution realm-associated deficiencies and to groundwater viral and disinfection-only system outbreaks.

  17. Cold/menthol TRPM8 receptors initiate the cold-shock response and protect germ cells from cold-shock-induced oxidation.

    Science.gov (United States)

    Borowiec, Anne-Sophie; Sion, Benoit; Chalmel, Frédéric; D Rolland, Antoine; Lemonnier, Loïc; De Clerck, Tatiana; Bokhobza, Alexandre; Derouiche, Sandra; Dewailly, Etienne; Slomianny, Christian; Mauduit, Claire; Benahmed, Mohamed; Roudbaraki, Morad; Jégou, Bernard; Prevarskaya, Natalia; Bidaux, Gabriel

    2016-09-01

    Testes of most male mammals present the particularity of being externalized from the body and are consequently slightly cooler than core body temperature (4-8°C below). Although, hypothermia of the testis is known to increase germ cells apoptosis, little is known about the underlying molecular mechanisms, including cold sensors, transduction pathways, and apoptosis triggers. In this study, using a functional knockout mouse model of the cold and menthol receptors, dubbed transient receptor potential melastatine 8 (TRPM8) channels, we found that TRPM8 initiated the cold-shock response by differentially modulating cold- and heat-shock proteins. Besides, apoptosis of germ cells increased in proportion to the cooling level in control mice but was independent of temperature in knockout mice. We also observed that the rate of germ cell death correlated positively with the reactive oxygen species level and negatively with the expression of the detoxifying enzymes. This result suggests that the TRPM8 sensor is a key determinant of germ cell fate under hypothermic stimulation.-Borowiec, A.-S., Sion, B., Chalmel, F., Rolland, A. D., Lemonnier, L., De Clerck, T., Bokhobza, A., Derouiche, S., Dewailly, E., Slomianny, C., Mauduit, C., Benahmed, M., Roudbaraki, M., Jégou, B., Prevarskaya, N., Bidaux, G. Cold/menthol TRPM8 receptors initiate the cold-shock response and protect germ cells from cold-shock-induced oxidation. © The Author(s).

  18. Application study of monthly precipitation forecast in Northeast China based on the cold vortex persistence activity index

    Science.gov (United States)

    Gang, Liu; Meihui, Qu; Guolin, Feng; Qucheng, Chu; Jing, Cao; Jie, Yang; Ling, Cao; Yao, Feng

    2018-03-01

    This paper introduces three quantitative indicators to conduct research for characterizing Northeast China cold vortex persistence activity: cold vortex persistence, generalized "cold vortex," and cold vortex precipitation. As discussed in the first part of paper, a hindcast is performed by multiple regressions using Northeast China precipitation from 2012 to 2014 combination with the previous winter 144 air-sea system factors. The results show that the mentioned three cold vortex index series can reflect the spatial and temporal distributions of observational precipitation in 2012-2014 and obtain results. The cold vortex factors are then added to the Forecast System on Dynamical and Analogy Skills (FODAS) to carry out dynamic statistical hindcast of precipitation in Northeast China from 2003 to 2012. Based on the characteristics and significance of each index, precipitation hindcast is carried out for Northeast China in May, June, July, August, May-June, and July-August. It turns out that the Northeast Cold Vortex Index Series, as defined in this paper, can make positive corrections to the FODAS forecast system, and most of the index correction results are higher than the system's own correction value. This study provides quantitative index products and supplies a solid technical foundation and support for monthly precipitation forecast in Northeast China.

  19. Perceptions of vulnerability to a future outbreak: a study of horse managers affected by the first Australian equine influenza outbreak

    Science.gov (United States)

    2013-01-01

    Background A growing body of work shows the benefits of applying social cognitive behavioural theory to investigate infection control and biosecurity practices. Protection motivation theory has been used to predict protective health behaviours. The theory outlines that a perception of a lack of vulnerability to a disease contributes to a reduced threat appraisal, which results in poorer motivation, and is linked to poorer compliance with advised health protective behaviours. This study, conducted following the first-ever outbreak of equine influenza in Australia in 2007, identified factors associated with horse managers’ perceived vulnerability to a future equine influenza outbreak. Results Of the 200 respondents, 31.9% perceived themselves to be very vulnerable, 36.6% vulnerable and 31.4% not vulnerable to a future outbreak of equine influenza. Multivariable logistic regression modelling revealed that managers involved in horse racing and those on rural horse premises perceived themselves to have low levels of vulnerability. Managers of horse premises that experienced infection in their horses in 2007 and those seeking infection control information from specific sources reported increased levels of perceived vulnerability to a future outbreak. Conclusion Different groups across the horse industry perceived differing levels of vulnerability to a future outbreak. Increased vulnerability contributes to favourable infection control behaviour and hence these findings are important for understanding uptake of recommended infection control measures. Future biosecurity communication strategies should be delivered through information sources suitable for the horse racing and rural sectors. PMID:23902718

  20. Perceptions of vulnerability to a future outbreak: a study of horse managers affected by the first Australian equine influenza outbreak.

    Science.gov (United States)

    Schemann, Kathrin; Firestone, Simon M; Taylor, Melanie R; Toribio, Jenny-Ann L M L; Ward, Michael P; Dhand, Navneet K

    2013-07-31

    A growing body of work shows the benefits of applying social cognitive behavioural theory to investigate infection control and biosecurity practices. Protection motivation theory has been used to predict protective health behaviours. The theory outlines that a perception of a lack of vulnerability to a disease contributes to a reduced threat appraisal, which results in poorer motivation, and is linked to poorer compliance with advised health protective behaviours. This study, conducted following the first-ever outbreak of equine influenza in Australia in 2007, identified factors associated with horse managers' perceived vulnerability to a future equine influenza outbreak. Of the 200 respondents, 31.9% perceived themselves to be very vulnerable, 36.6% vulnerable and 31.4% not vulnerable to a future outbreak of equine influenza. Multivariable logistic regression modelling revealed that managers involved in horse racing and those on rural horse premises perceived themselves to have low levels of vulnerability. Managers of horse premises that experienced infection in their horses in 2007 and those seeking infection control information from specific sources reported increased levels of perceived vulnerability to a future outbreak. Different groups across the horse industry perceived differing levels of vulnerability to a future outbreak. Increased vulnerability contributes to favourable infection control behaviour and hence these findings are important for understanding uptake of recommended infection control measures. Future biosecurity communication strategies should be delivered through information sources suitable for the horse racing and rural sectors.

  1. A large rubella outbreak with spread from the workplace to the community.

    Science.gov (United States)

    Danovaro-Holliday, M C; LeBaron, C W; Allensworth, C; Raymond, R; Borden, T G; Murray, A B; Icenogle, J P; Reef, S E

    2000-12-06

    Childhood vaccination has reduced rubella disease to low levels in the United States, but outbreaks continue to occur. The largest outbreak in the past 5 years occurred in Nebraska in 1999. To examine risk factors for disease, susceptibility of the risk population, role of vaccine failure, and the need for new vaccination strategies in response to the Nebraska rubella outbreak. Investigation of 83 confirmed rubella cases occurring in Douglas County, Nebraska, between March 23 and August 24, 1999; serosurvey of 413 pregnant women in the outbreak locale between October 1998 and March 1999 (prior to outbreak) and April and November 1999 (during and after outbreak). Case characteristics, compared with that of the general county population; area childhood rubella vaccination rates; and susceptibility among pregnant women before vs during and after the outbreak. All 83 rubella cases were unvaccinated or had unknown vaccination status and fell into 3 groups: (1) 52 (63%) were young adults (median age, 26 years), 83% of whom were born in Latin American countries where rubella vaccination was not routine. They were either employed in meatpacking plants or were their household contacts. Attack rates in the plants were high (14.4 per 1000 vs 0. 19 per 1000 for general county population); (2) 16 (19%), including 14 children (9 of whom were aged pregnant women, susceptibility rates were 13% before the outbreak and 11% during and after the outbreak. Six (25%) of 24 susceptible women tested were seropositive for rubella IgM. Rubella vaccination rates were 90.2% for preschool children and 99.8% for school-aged children. A large rubella outbreak occurred among unvaccinated persons in a community with high immunity levels. Crowded working and living conditions facilitated transmission, but vaccine failure did not. Workplace vaccination could be considered to prevent similar outbreaks. JAMA. 2000;284:2733-2739.

  2. Cold stress alters transcription in meiotic anthers of cold tolerant chickpea (Cicer arietinum L.).

    Science.gov (United States)

    Sharma, Kamal Dev; Nayyar, Harsh

    2014-10-11

    Cold stress at reproductive phase in susceptible chickpea (Cicer arietinum L.) leads to pollen sterility induced flower abortion. The tolerant genotypes, on the other hand, produce viable pollen and set seed under cold stress. Genomic information on pollen development in cold-tolerant chickpea under cold stress is currently unavailable. DDRT-PCR analysis was carried out to identify anther genes involved in cold tolerance in chickpea genotype ICC16349 (cold-tolerant). A total of 9205 EST bands were analyzed. Cold stress altered expression of 127 ESTs (90 up-regulated, 37 down-regulated) in anthers, more than two third (92) of which were novel with unknown protein identity and function. Remaining about one third (35) belonged to several functional categories such as pollen development, signal transduction, ion transport, transcription, carbohydrate metabolism, translation, energy and cell division. The categories with more number of transcripts were carbohydrate/triacylglycerol metabolism, signal transduction, pollen development and transport. All but two transcripts in these categories were up-regulated under cold stress. To identify time of regulation after stress and organ specificity, expression levels of 25 differentially regulated transcripts were also studied in anthers at six time points and in four organs (anthers, gynoecium, leaves and roots) at four time points. Limited number of genes were involved in regulating cold tolerance in chickpea anthers. Moreover, the cold tolerance was manifested by up-regulation of majority of the differentially expressed transcripts. The anthers appeared to employ dual cold tolerance mechanism based on their protection from cold by enhancing triacylglycerol and carbohydrate metabolism; and maintenance of normal pollen development by regulating pollen development genes. Functional characterization of about two third of the novel genes is needed to have precise understanding of the cold tolerance mechanisms in chickpea anthers.

  3. Outbreaks of forest defoliating insects in Japan, 1950-2000.

    Science.gov (United States)

    Kamata, N; Kamata, N

    2002-04-01

    In Japan, several forest-defoliating insects reach outbreak levels and cause serious defoliation. Stand mortality sometimes occurs after severe defoliation. However, in general, tree mortality caused by insect defoliation is low because of the prevailing moist climate in Japan. Evergreen conifers are more susceptible to tree mortality as a result of insect defoliation whereas deciduous broad-leaved trees are seldom killed. Insect defoliation occurs more frequently in man-made environments such as among shade trees, orchards, and plantations than in natural habitats. Outbreaks of some defoliators tend to occur in stands of a particular age: e.g. outbreaks of the pine caterpillar, Dendrolimus spectabilis Butler (Lepidoptera: Lasiocampidae) occur more frequently in young pine plantations. In contrast, defoliation caused by outbreaks of lepidopterous and hymenopterous pests in larch plantations is more frequent with stand maturation. There is a relationship between outbreaks of some defoliators and altitude above sea level. Most outbreaks of forest defoliators were terminated by insect pathogens that operated in a density-dependent fashion. Since the 1970s, Japan has been prosperous and can afford to buy timber from abroad. More recently, there has been an increasing demand for timber in Japan, that coincides with a huge demand internationally, so that the country will need to produce more timber locally in the future. The increasing pressure on the forestry industry to meet this demand will require more sophisticated methods of pest control coupled with more sustainable methods of silviculture.

  4. Evaluation of Two Compressed Air Foam Systems for Culling Caged Layer Hens

    Science.gov (United States)

    Weiher, Jaclyn A.; Alphin, Robert L.; Hougentogler, Daniel P.

    2018-01-01

    Simple Summary Control of avian influenza and similar diseases in commercial poultry operations is challenging; the six major steps are surveillance, biosecurity, quarantine, depopulation, disposal, and cleaning and disinfection. Depopulation is used to cull animals that are terminally ill and to reduce the number of animals that can spread an untreatable disease. Water-based foam depopulation was used effectively during the 2014–2015 highly pathogenic avian influenza outbreak in the United States. Water-based foam, however, cannot be used effectively in caged poultry operations. Compressed air foam systems were initially developed for structural fire-fighting and, with modifications, can provide the conditions required to effectively penetrate a poultry cage and provide sufficient residence time for depopulation. In this experiment, compressed air foam was used to depopulate caged layer hens. Compressed air foam resulted in faster unconsciousness than carbon dioxide gassing. The experiment demonstrated that compressed air foam systems have promise for depopulating birds raised in cages. Abstract Outbreaks of avian influenza (AI) and other highly contagious poultry diseases continue to be a concern for those involved in the poultry industry. In the situation of an outbreak, emergency depopulation of the birds involved is necessary. In this project, two compressed air foam systems (CAFS) were evaluated for mass emergency depopulation of layer hens in a manure belt equipped cage system. In both experiments, a randomized block design was used with multiple commercial layer hens treated with one of three randomly selected depopulation methods: CAFS, CAFS with CO2 gas, and CO2 gas. In Experiment 1, a Rowe manufactured CAFS was used, a selection of birds were instrumented, and the time to unconsciousness, brain death, altered terminal cardiac activity and motion cessation were recorded. CAFS with and without CO2 was faster to unconsciousness, however, the other

  5. The lab and the land: overcoming the Arctic in Cold War Alaska.

    Science.gov (United States)

    Farish, Matthew

    2013-03-01

    The militarization of Alaska during and after World War II created an extraordinary set of new facilities. But it also reshaped the imaginative role of Alaska as a hostile environment, where an antagonistic form of nature could be defeated with the appropriate combination of technology and training. One of the crucial sites for this reformulation was the Arctic Aeromedical Laboratory, based at Ladd Air Force Base in Fairbanks. In the first two decades of the Cold War, its employees conducted numerous experiments on acclimatization and survival. The laboratory is now best known for an infamous set of tests involving the application of radioactive tracers to indigenous Alaskans--experiments publicized by post-Cold War panels established to evaluate the tragic history of atomic-era human subject research. But little else has been written about the laboratory's relationship with the populations and landscapes that it targeted for study. This essay presents the laboratory as critical to Alaska's history and the history of the Cold War sciences. A consideration of the laboratory's various projects also reveals a consistent fascination with race. Alaskan Natives were enrolled in experiments because their bodies were understood to hold clues to the mysteries of northern nature. A scientific solution would aid American military campaigns not only in Alaska, but in cold climates everywhere.

  6. Comparing "insider" and "outsider" news coverage of the 2014 Ebola outbreak.

    Science.gov (United States)

    Humphries, Brittany; Radice, Martha; Lauzier, Sophie

    2017-11-09

    Information provided by news media during an infectious disease outbreak can affect the actions taken to safeguard public health. There has been little evaluation of how the content of news published during an outbreak varies by location of the news outlet. This study analyzes coverage of the 2014 Ebola outbreak by one news outlet operating within a country affected by the outbreak and one country not directly affected. A qualitative content analysis was conducted of articles published in two national news outlets, The Globe and Mail (Canada) and the Vanguard (Nigeria), between January 1 and December 31, 2014. Articles available through LexisNexis Academic were sorted by date and sampled using a stratified sampling method (The Globe and Mail n = 100; Vanguard n = 105). A coding scheme was developed and modified to incorporate emerging themes until saturation was achieved. There were substantial differences in outbreak coverage in terms of the topic and content of the articles, as well as the sources consulted. The Globe and Mail framed the outbreak in terms of national security and national interests, as well as presenting it as an international humanitarian crisis. In contrast, the Vanguard framed the outbreak almost exclusively in terms of public health. Our findings highlight how different geographic contexts can shape reporting on the same event. Further research is required to investigate how the political, social or economic situations of a country shape its news media, potentially influencing actions taken to control disease outbreaks.

  7. Cough & Cold Medicine Abuse

    Science.gov (United States)

    ... Videos for Educators Search English Español Cough & Cold Medicine Abuse KidsHealth / For Teens / Cough & Cold Medicine Abuse ... resfriado Why Do People Use Cough and Cold Medicines to Get High? There's an ingredient in many ...

  8. Human angiostrongyliasis outbreak in Dali, China.

    Directory of Open Access Journals (Sweden)

    Shan Lv

    Full Text Available BACKGROUND: Several angiostrongyliasis outbreaks have been reported in recent years but the disease continues to be neglected in public health circles. We describe an outbreak in Dali, southwest China in order to highlight some key problems for the control of this helminth infection. METHODOLOGY/PRINCIPAL FINDINGS: All available medical records of suspected angiostrongyliasis patients visiting hospitals in Dali in the period 1 October 2007-31 March 2008 were reviewed, and tentative diagnoses of varying strengths were reached according to given sets of criteria. Snails collected from local markets, restaurants and natural habitats were also screened for the presence of Angiostrongylus cantonensis. A total of 33 patients met criteria for infection, and 11 among them were classified as clinically confirmed. An additional eight patients were identified through a surveillance system put in operation in response to the outbreak. The epidemic lasted for 8 months with its peak in February 2008. Of the 33 patients, 97.0% complained of severe headache. 84.8% patients had high eosinophil cell counts either in the peripheral blood or in cerebrospinal fluid (CSF. Three-quarters of the patients were treated with a combination of albendazole and corticosteroids, resulting in significantly improved overall conditions. Twenty-two patients reported the consumption of raw or undercooked snails prior to the onset of the symptoms, and approximately 1.0% of the Pomacea canaliculata snails on sale were found to be infected with A. cantonensis. The snails were also found in certain habitats around Dali but no parasites were detected in these populations. CONCLUSIONS/SIGNIFICANCE: The import and sale of infected P. canaliculata is the likely trigger for this angiostrongyliasis outbreak. Awareness of angiostrongyliasis must be raised, and standardized diagnosis and treatment are needed in order to provide clinicians with a guide to address this disease. Health education

  9. Molecular Characterization of Two Major Dengue Outbreaks in Costa Rica.

    Science.gov (United States)

    Soto-Garita, Claudio; Somogyi, Teresita; Vicente-Santos, Amanda; Corrales-Aguilar, Eugenia

    2016-07-06

    Dengue virus (DENV) (Flavivirus, Flaviviridae) is a reemerging arthropod-borne virus with a worldwide circulation, transmitted mainly by Aedes aegypti and Aedes albopictus mosquitoes. Since the first detection of its main transmitting vector in 1992 and the invasion of DENV-1 in 1993, Costa Rica has faced dengue outbreaks yearly. In 2007 and 2013, Costa Rica experienced two of the largest outbreaks in terms of total and severe cases. To provide genetic information about the etiologic agents producing these outbreaks, we conducted phylogenetic analysis of viruses isolated from human samples. A total of 23 DENV-1 and DENV-2 sequences were characterized. These analyses signaled that DENV-1 genotype V and DENV-2 American/Asian genotype were circulating in those outbreaks. Our results suggest that the 2007 and 2013 outbreak viral strains of DENV-1 and DENV-2 originated from nearby countries and underwent in situ microevolution. © The American Society of Tropical Medicine and Hygiene.

  10. An isolated outbreak of diphtheria in South Africa, 2015.

    Science.gov (United States)

    Mahomed, S; Archary, M; Mutevedzi, P; Mahabeer, Y; Govender, P; Ntshoe, G; Kuhn, W; Thomas, J; Olowolagba, A; Blumberg, L; McCarthy, K; Mlisana, K; DU Plessis, M; VON Gottberg, A; Moodley, P

    2017-07-01

    An outbreak of respiratory diphtheria occurred in two health districts in the province of KwaZulu-Natal in South Africa in 2015. A multidisciplinary outbreak response team was involved in the investigation and management of the outbreak. Fifteen cases of diphtheria were identified, with ages ranging from 4 to 41 years. Of the 12 cases that were under the age of 18 years, 9 (75%) were not fully immunized for diphtheria. The case fatality was 27%. Ninety-three household contacts, 981 school or work contacts and 595 healthcare worker contacts were identified and given prophylaxis against Corynebacterium diphtheriae infection. A targeted vaccination campaign for children aged 6-15 years was carried out at schools in the two districts. The outbreak highlighted the need to improve diphtheria vaccination coverage in the province and to investigate the feasibility of offering diphtheria vaccines to healthcare workers.

  11. Longevity and fecundity of Dichroplus maculipennis (Orthoptera, Acrididae at non-outbreaking and outbreaking situations Longevidade e fecundidade de Dichroplus maculipennis (Orthoptera: Acrididae: Melanoplinae em situações de "non-outbreaking" e "outbreaking"

    Directory of Open Access Journals (Sweden)

    Yanina Mariottini

    2011-09-01

    Full Text Available Dichroplus maculipennis is one of the most characteristic and damaging grasshopper species of Argentina, mainly in areas of the Pampas and Patagonia regions. We estimated and compared the longevity and fecundity of adult female D. maculipennis under controlled conditions (30ºC, 14L:10D, 40% RH from individuals collected as last instar nymphs (VI in the field and with a known recent history of low and high density conditions. Densities of D. maculipennis at the collecting sites were 0.95 individuals per m² in 2006 and 46 ind/m² in 2009, representing non-outbreaking and outbreaking situations, respectively. Adult female longevity in 2006 (67.96 ± 3.2 days was significantly higher (p 0.05. The fecundity curves showed that the highest values were at weeks 11 and 13 for the 2006 females, and at week 6 for those of 2009. Since the daily oviposition rate at low and high densities was not significantly different, the diminished fecundity rate at high density is attributable to their reduced longevity.O gafanhoto Dichroplus maculipennis é um dos mais característicos e prejudiciales da Argentina, principalmente nas regiões das Pampas e da Patagonia. O objetivo deste estudo foi estimar e comparar a longevidade e fecundidade das fêmeas adultas do D. maculipennis sob condições controladas (30ºC, 14 luz: 10 obscuridad, 40% RH a partir do indivíduos coletados em campo como ultimo estadio ninfal (VI e con historia recente conocida de baixas e altas densidades. As densidades de D. maculipennis nos locais de coleta foram de 0.95 indivíduos por m² em 2006 e 46 indivíduos/m² em 2009, representando situações de "non-outbreaking" e "outbreaking", respectivamente. A longevidade das fêmeas adultas em 2006 (67.96 ± 3.2 dias foi significamente maior (p 0.05. No entanto, as baixas taxas de fecundidade das fêmeas em densidades elevadas, se devem, provavelmente à longevidade reduzida.

  12. The Corrosion Behavior of Cold-Rolled 304 Stainless Steel In Salt Spray Environments

    International Nuclear Information System (INIS)

    Chiang, M.F.; Young, M.C.; Huang, J.Y.

    2011-01-01

    Saline corrosion is one of the major degradation mechanisms for stainless steel type 304 (SS304) dry storage cask during the spent fuel interim storage period. Slow strain rate test (SSRT) and neutral salt spray test (NSS) were performed at 85 degrees Celsius and 200 degrees Celsius with 0.5 wt% sodium chloride mist sprayed on the cold-rolled SS304 specimens of different degrees of reduction in this study. The weight changes of the NSS specimens tested at 85 degrees Celsius for 2000 hours differed greatly from those at 200 degrees Celsius. The weight loss of NSS specimens was not significant at 85 degrees Celsius but the weight gain decreased gradually with increasing the cold-rolled reduction. The yield strength (YS) and ultimate tensile stress (UTS) values obtained from the SSRT tests for lightly cold-rolled specimens in the salt spray environment at 85 degrees Celsius and 200 degrees Celsius are slightly lower than in air. But for those with 20% reductions, the specimen strengths were no longer changed by the saline corrosion. The preliminary results demonstrated that the quality and performance of cold-rolled SS304 is acceptable for fabrication of dry storage casks. However, more work on the corrosion behavior of cold-rolled stainless steel in the saline atmosphere is needed to better understand its long-term performance.

  13. Electrically heated catalysts for cold-start emission control on gasoline- and methanol-fueled vehicles

    International Nuclear Information System (INIS)

    Heimrich, M.J.; Albu, S.; Ahuja, M.

    1992-01-01

    Cold-start emissions from current technology vehicles equipped with catalytic converters can account for over 80 percent of the emissions produced during the Federal Test Procedure (FTP). Excessive pollutants can be emitted for a period of one to two minutes following cold engine starting, partially because the catalyst has not reached an efficient operating temperature. Electrically heated catalysts, which are heated prior to engine starting, have been identified as a potential strategy for controlling cold-start emissions. This paper summarizes the emission results of three gasoline-fueled and three methanol-fueled vehicles equipped with electrically heated catalyst systems. Results from these vehicles demonstrate that heated catalyst technology can provide FTP emission levels of nonmethane organic gases (NMOG), carbon monoxide (CO), and oxides of nitrogen (NO x ) that show promise of meeting the Ultra-Low Emission Vehicle (ULEV) standards established by the California Air Resources Board

  14. Bjerknes' hypothesis on the coldness during AD 1790-1820 revisited

    Energy Technology Data Exchange (ETDEWEB)

    Schrier, G. van der [UEA, Climatic Research Unit, Norwich (United Kingdom); Barkmeijer, J. [Royal Netherlands Meteorological Institute (KNMI), De Bilt (Netherlands)

    2005-03-01

    The aim of this paper is to re-examine and quantify a hypothesis first put forward by J. Bjerknes concerning the anomalous coldness during the AD 1790-1820 period in western Europe. Central to Bjerknes' hypothesis is an anomalous interaction between ocean and atmosphere studied here using an ocean-atmosphere coupled climate model of intermediate complexity. A reconstruction of the sea-level pressure pattern over the North Atlantic sector averaged over the period 1790-1820 is assimilated in this model, using a recently developed technique which has not been applied to paleoclimatic modelling before. This technique ensures that averaged over the simulation the reconstructed pattern is retrieved whilst leaving atmospheric and climatic variability to develop freely. In accordance with Bjerknes' hypothesis, the model results show anomalous southward advection of polar waters into the northeastern North Atlantic in the winter season, lowering the sea-surface temperatures (SSTs) there with 0.3-1.0 C. This SST anomaly is persistent into the summer season. A decrease in western European winter surface air temperatures is found which can be related almost completely to advection of cold polar air. The decrease in summer surface air temperatures is related to a combination of low SSTs and anomalous atmospheric circulation. The modelled winter and summer temperatures in Europe compare favourably with reconstructed temperatures. Enhanced baroclinicity at the Atlantic seaboard and over Baffin Island is observed along with more variability in the position of the North Atlantic storm tracks. The zone of peak winter storm frequency is drawn to the European mid-latitudes. (orig.)

  15. Analysis on energy-saving path of rural buildings in hot summer and cold winter zone

    Science.gov (United States)

    Huang, Mingqiang; Li, Jinheng

    2018-02-01

    Since the reform and opening policy, the construction of rural area in China has become more and more important. The idea of establishing green villages needs to be accepted and recognized by the public. The hot summer and cold winter zone combines two contradictory weather conditions that is cold winter and hot summer. So the living conditions are limited. In response to this climate, residents extensively use electric heaters or air conditioning to adjust the indoor temperature, resulting in energy waste and environmental pollution. In order to improve the living conditions of residents, rural area energy conservation has been put on the agenda. Based on the present situation and energy consumption analysis of the rural buildings in the hot summer and cold winter zone, this article puts forward several energy saving paths from government, construction technology and so on

  16. Thermal comfort and indoor air quality in rooms with integrated personalized ventilation and under-floor air distribution systems

    DEFF Research Database (Denmark)

    Li, Ruixin; Sekhar ., S. C.; Melikov, Arsen Krikor

    2011-01-01

    A comprehensive study comprising physical measurements and human subject experiments was conducted to explore the potential for improving occupants' thermal comfort and indoor air quality (IAQ) using a personalized ventilation (PV) system combined with an under-floor air distribution(UFAD) system....... The integrated PV-UFAD system, when operated at relatively high temperature of the air supplied from the UFAD system, provided comfortable cooling of the facial region, improved inhaled air quality, and decreased the risk of "cold feet," which is often reported in rooms with UFAD alone. This article explores...... and a secondary AHU for 100% recirculated air that is supplied through UFAD outlets. Velocity and temperature distribution in the chamber were measured. A breathing thermal manikin was used to measure the heat loss from 26 body segments and to determine the equivalent temperature. The responses of 30 human...

  17. Experimental evaluation on energy performance of innovative clean air heat pump for indoor environment control in summer and winter seasons

    DEFF Research Database (Denmark)

    Nie, Jinzhe; Fang, Lei; Olesen, Bjarne W.

    2014-01-01

    Based on the air purification capacity of regenerative silica gel rotor, an innovative clean air heat pump (CAHP) was designed, developed and investigated through experimental studies. The CAHP integrated air purification, dehumidification and heating/cooling in one unit. A prototype of the CAHP...... was developed. Laboratory experimental studies were conducted to investigate its energy performance under different outdoor climates including cold, mild-cold, mild-hot and extremely hot and humid climates. The energy performance of the CAHP was then evaluated by comparing with a conventional air source heat...... pump. The results showed that to keep same indoor air quality, the CAHP could save substantial amount of energy. For example, compared to the conventional air source heat pump, the CAHP could save up to 59%, 40%, 30% of electricity for ventilation and air conditioning in a test room in summer...

  18. Measles outbreak response decision-making under uncertainty: a retrospective analysis.

    Science.gov (United States)

    Fonnesbeck, Christopher J; Shea, Katriona; Carran, Spencer; Cassio de Moraes, Jose; Gregory, Christopher; Goodson, James L; Ferrari, Matthew J

    2018-03-01

    Resurgent outbreaks of vaccine-preventable diseases that have previously been controlled or eliminated have been observed in many settings. Reactive vaccination campaigns may successfully control outbreaks but must necessarily be implemented in the face of considerable uncertainty. Real-time surveillance may provide critical information about at-risk population and optimal vaccination targets, but may itself be limited by the specificity of disease confirmation. We propose an integrated modelling approach that synthesizes historical demographic and vaccination data with real-time outbreak surveillance via a dynamic transmission model and an age-specific disease confirmation model. We apply this framework to data from the 1996-1997 measles outbreak in São Paulo, Brazil. To simulate the information available to decision-makers, we truncated the surveillance data to what would have been available at 1 or 2 months prior to the realized interventions. We use the model, fitted to real-time observations, to evaluate the likelihood that candidate age-targeted interventions could control the outbreak. Using only data available prior to the interventions, we estimate that a significant excess of susceptible adults would prevent child-targeted campaigns from controlling the outbreak and that failing to account for age-specific confirmation rates would underestimate the importance of adult-targeted vaccination. © 2018 The Author(s).

  19. An outbreak of enterotoxigenic Escherichia coli (ETEC) infection in Norway, 2012: a reminder to consider uncommon pathogens in outbreaks involving imported products.

    Science.gov (United States)

    MacDonald, E; Møller, K E; Wester, A L; Dahle, U R; Hermansen, N O; Jenum, P A; Thoresen, L; Vold, L

    2015-02-01

    We investigated an outbreak of gastroenteritis following a Christmas buffet served on 4-9 December 2012 to ~1300 hotel guests. More than 300 people were reported ill in initial interviews with hotel guests. To identify possible sources of infection we conducted a cohort investigation through which we identified 214 probable cases. Illness was associated with consumption of scrambled eggs (odds ratio 9·07, 95% confidence interval 5·20-15·84). Imported chives added fresh to the scrambled eggs were the suspected source of the outbreak but were unavailable for testing. Enterotoxigenic Escherichia coli (ETEC) infection was eventually confirmed in 40 hotel guests. This outbreak reinforces that ETEC should be considered in non-endemic countries when the clinical picture is consistent and common gastrointestinal pathogens are not found. Following this outbreak, the Norwegian Food Safety Authority recommended that imported fresh herbs should be heat-treated before use in commercial kitchens.

  20. A Methanol Intoxication Outbreak From Recreational Ingestion of Fracking Fluid.

    Science.gov (United States)

    Collister, David; Duff, Graham; Palatnick, Wesley; Komenda, Paul; Tangri, Navdeep; Hingwala, Jay

    2017-05-01

    Single-patient methanol intoxications are a common clinical presentation, but outbreaks are rare and usually occur in settings in which there is limited access to ethanol and methanol is consumed as a substitute. In this case report, we describe an outbreak of methanol intoxications that was challenging from a public health perspective and discuss strategies for managing such an outbreak. Copyright © 2016 National Kidney Foundation, Inc. Published by Elsevier Inc. All rights reserved.

  1. Recovery benefits of using a heat and moisture exchange mask during sprint exercise in cold temperatures.

    Science.gov (United States)

    Seifert, John G; Frost, Jeremy; St Cyr, John A

    2017-01-01

    Breathing cold air can lead to bronchoconstriction and peripheral vasoconstriction, both of which could impact muscular performance by affecting metabolic demands during exercise. Successful solutions dealing with these physiological changes during exercise in the cold has been lacking; therefore, we investigated the influence of a heat and moisture exchange mask during exercise in the cold. There were three trial arms within this study: wearing the heat and moisture exchange mask during the rest periods in the cold, no-mask application during the rest periods in the cold, and a trial at room temperature (22°C). Eight subjects cycled in four 35 kJ sprint sessions with each session separated by 20 min rest period. Workload was 4% of body mass. Mean sprint times were faster with heat and moisture exchange mask and room temperature trial than cold, no-mask trial (133.8 ± 8.6, 134.9 ± 8.8, and 138.0 ± 8.4 s (p = 0.001)). Systolic blood pressure and mean arterial pressure were greater during the cold trial with no mask (15% and 13%, respectively), and heart rate was 10 bpm less during the third rest or recovery period during cold, no mask compared to the heat and moisture exchange mask and room temperature trials. Subjects demonstrated significant decreases in vital capacity and peak expiratory flow rate during the cold with no mask applied during the rest periods. These negative responses to cold exposure were alleviated by the use of a heat and moisture exchange mask worn during the rest intervals by minimizing cold-induced temperature stress on the respiratory system with subsequent maintenance of cardiovascular function.

  2. Characteristics of wild polio virus outbreak investigation and response in Ethiopia in 2013-2014: implications for prevention of outbreaks due to importations.

    Science.gov (United States)

    Tegegne, Ayesheshem Ademe; Braka, Fiona; Shebeshi, Meseret Eshetu; Aregay, Aron Kassahun; Beyene, Berhane; Mersha, Amare Mengistu; Ademe, Mohammed; Muhyadin, Abdulahi; Jima, Dadi; Wyessa, Abyot Bekele

    2018-01-05

    Ethiopia joined the Global Polio Eradication Initiative (GPEI) in 1996, and by the end of December 2001 circulation of indigenous Wild Polio Virus (WPV) had been interrupted. Nonetheless, the country experienced multiple importations during 2004-2008, and in 2013. We characterize the 2013 outbreak investigations and response activities, and document lessons learned. The data were pulled from different field investigation reports and from the national surveillance database for Acute Flaccid Paralysis (AFP). In 2013, a WPV1 outbreak was confirmed following importation in Dollo zone of the Somali region, which affected three Woredas (Warder, Geladi and Bokh). Between July 10, 2013, and January 5, 2014, there were 10 children paralyzed due to WPV1 infection. The majorities (7 of 10) were male and below 5 years of age, and 7 of 10 cases was not vaccinated, and 72% (92/129) of < 5 years of old children living in close proximity with WPV cases had zero doses of oral polio vaccine (OPV). The travel history of the cases showed that seven of the 10 cases had contact with someone who had traveled or had a travel history prior to the onset of paralysis. Underserved and inaccessibility of routine immunization service, suboptimal surveillance sensitivity, poor quality and inadequate supplemental immunization were the most crucial gaps identified during the outbreak investigations. Prior to the 2013 outbreak, Ethiopia experienced multiple imported polio outbreaks following the interruption of indigenous WPV in December 2001. The 2013 outbreak erupted due to massive population movement and was fueled by low population immunity as a result of low routine immunization and supplemental Immunization coverage and quality. In order to avert future outbreaks, it is critical that surveillance sensitivity be improved by establishing community-based surveillance systems and by assigning surveillance focal points at all level particularly in border areas. In addition, it is vital to set

  3. Direct radiative effects during intense Mediterranean desert dust outbreaks

    Directory of Open Access Journals (Sweden)

    A. Gkikas

    2018-06-01

    Full Text Available The direct radiative effect (DRE during 20 intense and widespread dust outbreaks, which affected the broader Mediterranean basin over the period March 2000–February 2013, has been calculated with the NMMB-MONARCH model at regional (Sahara and European continent and short-term temporal (84 h scales. According to model simulations, the maximum dust aerosol optical depths (AODs range from  ∼  2.5 to  ∼  5.5 among the identified cases. At midday, dust outbreaks locally induce a NET (shortwave plus longwave strong atmospheric warming (DREATM values up to 285 W m−2; Niger–Chad; dust AODs up to  ∼  5.5 and a strong surface cooling (DRENETSURF values down to −337 W m−2, whereas they strongly reduce the downward radiation at the ground level (DRESURF values down to −589 W m−2 over the Eastern Mediterranean, for extremely high dust AODs, 4.5–5. During night-time, reverse effects of smaller magnitude are found. At the top of the atmosphere (TOA, positive (planetary warming DREs up to 85 W m−2 are found over highly reflective surfaces (Niger–Chad; dust AODs up to  ∼  5.5 while negative (planetary cooling DREs down to −184 W m−2 (Eastern Mediterranean; dust AODs 4.5–5 are computed over dark surfaces at noon. Dust outbreaks significantly affect the mean regional radiation budget, with NET DREs ranging from −8.5 to 0.5 W m−2, from −31.6 to 2.1 W m−2, from −22.2 to 2.2 W m−2 and from −1.7 to 20.4 W m−2 for TOA, SURF, NETSURF and ATM, respectively. Although the shortwave DREs are larger than the longwave ones, the latter are comparable or even larger at TOA, particularly over the Sahara at midday. As a response to the strong surface day-time cooling, dust outbreaks cause a reduction in the regional sensible and latent heat fluxes by up to 45 and 4 W m−2, respectively, averaged over land areas of the simulation domain. Dust outbreaks reduce the

  4. GHOST: global hepatitis outbreak and surveillance technology.

    Science.gov (United States)

    Longmire, Atkinson G; Sims, Seth; Rytsareva, Inna; Campo, David S; Skums, Pavel; Dimitrova, Zoya; Ramachandran, Sumathi; Medrzycki, Magdalena; Thai, Hong; Ganova-Raeva, Lilia; Lin, Yulin; Punkova, Lili T; Sue, Amanda; Mirabito, Massimo; Wang, Silver; Tracy, Robin; Bolet, Victor; Sukalac, Thom; Lynberg, Chris; Khudyakov, Yury

    2017-12-06

    Hepatitis C is a major public health problem in the United States and worldwide. Outbreaks of hepatitis C virus (HCV) infections associated with unsafe injection practices, drug diversion, and other exposures to blood are difficult to detect and investigate. Effective HCV outbreak investigation requires comprehensive surveillance and robust case investigation. We previously developed and validated a methodology for the rapid and cost-effective identification of HCV transmission clusters. Global Hepatitis Outbreak and Surveillance Technology (GHOST) is a cloud-based system enabling users, regardless of computational expertise, to analyze and visualize transmission clusters in an independent, accurate and reproducible way. We present and explore performance of several GHOST implemented algorithms using next-generation sequencing data experimentally obtained from hypervariable region 1 of genetically related and unrelated HCV strains. GHOST processes data from an entire MiSeq run in approximately 3 h. A panel of seven specimens was used for preparation of six repeats of MiSeq libraries. Testing sequence data from these libraries by GHOST showed a consistent transmission linkage detection, testifying to high reproducibility of the system. Lack of linkage among genetically unrelated HCV strains and constant detection of genetic linkage between HCV strains from known transmission pairs and from follow-up specimens at different levels of MiSeq-read sampling indicate high specificity and sensitivity of GHOST in accurate detection of HCV transmission. GHOST enables automatic extraction of timely and relevant public health information suitable for guiding effective intervention measures. It is designed as a virtual diagnostic system intended for use in molecular surveillance and outbreak investigations rather than in research. The system produces accurate and reproducible information on HCV transmission clusters for all users, irrespective of their level of bioinformatics

  5. Commemoration of a cold war

    DEFF Research Database (Denmark)

    Farbøl, Rosanna

    2015-01-01

    This article brings together the fields of Cold War studies and memory studies. In Denmark, a remarkable institutionalisation of Cold War memory has taken place in the midst of a heated ideological battle over the past and whether to remember the Cold War as a ‘war’. Using Danish Cold War museums...... and heritage sites as case studies, this article sheds new light on the politics of history involved in Cold War commemoration. It suggests that the Cold War is commemorated as a war, yet this war memory is of a particular kind: it is a war memory without victims....

  6. Giardiasis in Bergen. Outbreak and clinical consequences.

    OpenAIRE

    Wensaas, Knut-Arne

    2011-01-01

    Background Giardia lamblia is a common cause of waterborne disease. It is endemic in many parts of the world, especially where sanitation is poor, but in Europe and North America it is most often encountered in outbreaks following contamination of drinking water. The first registered outbreak of giardiasis affecting a large community in Norway happened in Bergen in the autumn of 2004. The reservoir “Svartediket” was the source, and the water probably held Giardia cysts for s...

  7. An Outbreak of Sheep Pox in Zabajkalskij kray of Russia.

    Science.gov (United States)

    Maksyutov, R A; Gavrilova, E V; Agafonov, A P; Taranov, O S; Glotov, A G; Miheev, V N; Shchelkunov, S N; Sergeev, A N

    2015-08-01

    In this study, we investigated recent sheep pox outbreaks that occurred in Ononsky and Borzunsky regions of Zabajkalskij kray of Russia. The outbreaks involved in 2756 animals of which 112 were infected and 3 were slaughtered. Samples of injured skin of infected sheep were analysed by electron microscopy and CaPV-specific P32 gene amplification. Following sequence analysis of entire P32 gene showed that both specimens were identical to the sequence of several sheep poxvirus isolates from China and India. The close location of China to the last decade's Russian outbreaks suggest that possible future outbreaks in Russia could occur along the border regions with countries where sheep and goat pox are not controlled. © 2013 Blackwell Verlag GmbH.

  8. Cold thermal injury from cold caps used for the prevention of chemotherapy-induced alopecia.

    Science.gov (United States)

    Belum, Viswanath Reddy; de Barros Silva, Giselle; Laloni, Mariana Tosello; Ciccolini, Kathryn; Goldfarb, Shari B; Norton, Larry; Sklarin, Nancy T; Lacouture, Mario E

    2016-06-01

    The use of scalp cooling for the prevention of chemotherapy-induced alopecia (CIA) is increasing. Cold caps are placed onto the hair-bearing areas of the scalp for varying time periods before, during, and after cytotoxic chemotherapy. Although not yet reported, improper application procedures could result in adverse events (AEs). At present, there are no evidence-based scalp cooling protocols, and there is no regulatory oversight of their use. To report the occurrence of cold thermal injury (frostbite) on the scalp, following the use of cold caps for the prevention of CIA. We identified four patients who developed cold thermal injuries on the scalp following the application of cold caps. Medical records were analyzed to retrieve the demographic and clinical characteristics. The cold thermal injuries in our patients were grade 1/2 in severity and improved with topical interventions and interruption of cold cap use, although grade 1 persistent alopecia ensued in 3 patients. The true incidence of such injuries in this setting, however, remains unknown. Cold thermal injuries are likely infrequent and preventable AEs that may result from improper device application procedures during cold cap use. Although these untoward events are usually mild to moderate in severity, the potential occurrence of long-term sequelae (e.g., permanent alopecia and scarring) or the need to discontinue cold cap use, are not known. Prospective studies are needed to further elucidate the risk and standardize healthcare delivery methods, and to improve patient/supportive/healthcare provider education.

  9. Hydrogen outbreak of Zirconium Molybdate Hihydrate

    International Nuclear Information System (INIS)

    Miura, Yasuhiko; Fukuda, Kazuhiro; Ochi, Eiji

    2008-01-01

    JNFL is planning to construct a facility for enclosing the hull and end pieces produced due to reprocessing of spent fuel into stainless canisters after compressing, while those hull and end pieces enclosed into the stainless canisters are called 'compressed hulls'. Since the compressed hulls contain moisture absorbent Zirconium Molybdate Hihydrate accompanying hull and end pieces, there is a risk of outbreak of radiolysisradiolysis gas such as hydrogen, etc. by radiolysisradiolysis. This report intends to state the result of radiation irradiation experiment with the purpose of examining the volume of hydrogen outbreak from Zirconium Molybdate Hihydrate of the compressed hulls. (author)

  10. Landscape Epidemiology of Tularemia Outbreaks in Sweden

    Science.gov (United States)

    Svensson, Kerstin; Bäck, Erik; Eliasson, Henrik; Berglund, Lennart; Granberg, Malin; Karlsson, Linda; Larsson, Pär; Forsman, Mats

    2009-01-01

    Summer outbreaks of tularemia that occurred from 1995 through 2005 in 2 locations in Sweden affected 441 persons. We performed an epidemiologic investigation of these outbreaks using a novel strategy, involving high-resolution genotyping of Francisella tularensis isolates obtained from 136 patients (using 18 genetic markers developed from 6 F. tularensis genome sequences) and interviews with the patients. Strong spatial associations were found between F. tularensis subpopulations and the places of disease transmission; infection by some subpopulations occurred within areas as small as 2 km2, indicating unidentified environmental point sources of tularemia. In both locations, disease clusters were associated with recreational areas beside water, and genetic subpopulations were present throughout the tularemia season and persisted over years. High-resolution genotyping in combination with patients’ statements about geographic places of disease transmission provided valuable indications of likely sources of infection and the causal genotypes during these tularemia outbreaks. PMID:19961673

  11. Cholera Outbreaks in Urban Bangladesh In 2011.

    Science.gov (United States)

    Haque, Farhana; Hossain, M Jahangir; Kundu, Subodh Kumar; Naser, Abu Mohd; Rahman, Mahmudur; Luby, Stephen P

    In 2011, a multidisciplinary team investigated two diarrhoea outbreaks affecting urban Bangladeshi communities from the districts of Bogra and Kishorganj to identify etiology, pathways of transmission, and factors contributing to these outbreaks. We defined case-patients with severe diarrhoea as residents from affected communities admitted with ≥3 loose stools per day. We listed case-patients, interviewed and examined them, and collected rectal swabs. We visited the affected communities to explore the water and sanitation infrastructure. We tested the microbial load of water samples from selected case household taps, tube wells, and pump stations. We conducted anthropological investigations to understand community perceptions regarding the outbreaks. We identified 21 case-patients from Bogra and 84 from Kishorganj. The median age in Bogra was 23 years, and 21 years in Kishorganj. There were no reported deaths. We isolated Vibrio in 29% (5/17) of rectal swabs from Bogra and in 40% (8/20) from Kishorganj. We found Vibrio in 1/8 tap water samples from Bogra and in both of the samples from Kishorganj. We did not find Vibrio in water samples from pumps or tube wells in either outbreak. Ground water extracted through deep tube wells was supplied intermittently through interconnected pipes without treatment in both areas. We found leakages in the water pipes in Bogra, and in Kishorganj water pipes passed through open sewers. The rapid onset of severe diarrhoea predominantly affecting adults and the isolation of cholera in rectal swabs confirmed that these outbreaks were caused by Vibrio cholerae . The detection of Vibrio in water samples organisms from taps but not from pumps or tube wells, suggested contamination within the pipes. Safe water provision is difficult in municipalities where supply is intermittent, and where pipes commonly leak. Research to develop and evaluate water purification strategies could identify appropriate approaches for ensuring safe drinking

  12. Influenza outbreak during Sydney World Youth Day 2008: the utility of laboratory testing and case definitions on mass gathering outbreak containment.

    Directory of Open Access Journals (Sweden)

    Sebastiaan J van Hal

    Full Text Available BACKGROUND: Influenza causes annual epidemics and often results in extensive outbreaks in closed communities. To minimize transmission, a range of interventions have been suggested. For these to be effective, an accurate and timely diagnosis of influenza is required. This is confirmed by a positive laboratory test result in an individual whose symptoms are consistent with a predefined clinical case definition. However, the utility of these clinical case definitions and laboratory testing in mass gathering outbreaks remains unknown. METHODS AND RESULTS: An influenza outbreak was identified during World Youth Day 2008 in Sydney. From the data collected on pilgrims presenting to a single clinic, a Markov model was developed and validated against the actual epidemic curve. Simulations were performed to examine the utility of different clinical case definitions and laboratory testing strategies for containment of influenza outbreaks. Clinical case definitions were found to have the greatest impact on averting further cases with no added benefit when combined with any laboratory test. Although nucleic acid testing (NAT demonstrated higher utility than indirect immunofluorescence antigen or on-site point-of-care testing, this effect was lost when laboratory NAT turnaround times was included. The main benefit of laboratory confirmation was limited to identification of true influenza cases amenable to interventions such as antiviral therapy. CONCLUSIONS: Continuous re-evaluation of case definitions and laboratory testing strategies are essential for effective management of influenza outbreaks during mass gatherings.

  13. Aspects of cold intrusions over Greece during autumn

    Science.gov (United States)

    Mita, Constantina; Marinaki, Aggeliki; Zeini, Konstantina; Konstantara, Metaxia

    2010-05-01

    This study is focused on the description of atmospheric disturbances that caused intense cold intrusions over Greece during autumn for a period of 25 years (1982-2006). The study was based on data analysis from the meteorological station network of the Hellenic National Meteorological Service (HNMS) and the European Centre for Medium Range Weather Forecasts (ECMWF). Initially, the days with temperature at the isobaric surface of 850 hPa less or equal to the mean temperature for the 10-day period the day under investigation belongs to are isolated, composing a new confined data set which was further used. An event of intense cold intrusion is identified based on a subjective set of criteria, considering the temperature decrease at the level of 850 hPa and its duration. In particular, the criteria that were used to identify a cold intrusion were: temperature variation between two successive days at the isobaric level of 850 hPa being equal or greater than 50 C at least once during the event and duration of the event of at least two successive days with continuous temperature decrease. Additionally, the synoptic analysis of the atmospheric disturbances involved using weather charts from ECMWF, revealed that all cases were related to low pressure systems at the level of 500 hPa, accompanied by cold air masses. Moreover, a methodology proposed to classify the cold intrusions based on general circulation characteristics of the atmosphere, resulted in seven major categories. More than half of the events belong in two categories, originated northwest of the greater Greek area (Greece and parts of neighbouring countries), between 400 and 600 N. Further analysis indicated that the frequency of events increases from September to November and the majority of the events lasted two to three days. Additionally, the non-parametric Mann-Kendall test was used for the investigation of the statistical significance of the trends appearing in the results. The tests revealed that over

  14. An outbreak of respiratory tularemia caused by diverse clones of Francisella tularensis.

    Science.gov (United States)

    Johansson, Anders; Lärkeryd, Adrian; Widerström, Micael; Mörtberg, Sara; Myrtännäs, Kerstin; Ohrman, Caroline; Birdsell, Dawn; Keim, Paul; Wagner, David M; Forsman, Mats; Larsson, Pär

    2014-12-01

    The bacterium Francisella tularensis is recognized for its virulence, infectivity, genetic homogeneity, and potential as a bioterrorism agent. Outbreaks of respiratory tularemia, caused by inhalation of this bacterium, are poorly understood. Such outbreaks are exceedingly rare, and F. tularensis is seldom recovered from clinical specimens. A localized outbreak of tularemia in Sweden was investigated. Sixty-seven humans contracted laboratory-verified respiratory tularemia. F. tularensis subspecies holarctica was isolated from the blood or pleural fluid of 10 individuals from July to September 2010. Using whole-genome sequencing and analysis of single-nucleotide polymorphisms (SNPs), outbreak isolates were compared with 110 archived global isolates. There were 757 SNPs among the genomes of the 10 outbreak isolates and the 25 most closely related archival isolates (all from Sweden/Finland). Whole genomes of outbreak isolates were >99.9% similar at the nucleotide level and clustered into 3 distinct genetic clades. Unexpectedly, high-sequence similarity grouped some outbreak and archival isolates that originated from patients from different geographic regions and up to 10 years apart. Outbreak and archival genomes frequently differed by only 1-3 of 1 585 229 examined nucleotides. The outbreak was caused by diverse clones of F. tularensis that occurred concomitantly, were widespread, and apparently persisted in the environment. Multiple independent acquisitions of F. tularensis from the environment over a short time period suggest that natural outbreaks of respiratory tularemia are triggered by environmental cues. The findings additionally caution against interpreting genome sequence identity for this pathogen as proof of a direct epidemiological link. © The Author 2014. Published by Oxford University Press on behalf of the Infectious Diseases Society of America. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.

  15. Fault Tolerance Automotive Air-Ratio Control Using Extreme Learning Machine Model Predictive Controller

    OpenAIRE

    Pak Kin Wong; Hang Cheong Wong; Chi Man Vong; Tong Meng Iong; Ka In Wong; Xianghui Gao

    2015-01-01

    Effective air-ratio control is desirable to maintain the best engine performance. However, traditional air-ratio control assumes the lambda sensor located at the tail pipe works properly and relies strongly on the air-ratio feedback signal measured by the lambda sensor. When the sensor is warming up during cold start or under failure, the traditional air-ratio control no longer works. To address this issue, this paper utilizes an advanced modelling technique, kernel extreme learning machine (...

  16. An outbreak of Salmonella Typhimurium infections in Denmark, Norway and Sweden, 2008.

    Science.gov (United States)

    Bruun, T; Sørensen, G; Forshell, L P; Jensen, T; Nygard, K; Kapperud, G; Lindstedt, B A; Berglund, T; Wingstrand, A; Petersen, R F; Müller, L; Kjelsø, C; Ivarsson, S; Hjertqvist, M; Löfdahl, S; Ethelberg, S

    2009-03-12

    In November-December 2008, Norway and Denmark independently identified outbreaks of Salmonella Typhimurium infections characterised in the multiple-locus variable number of tandem repeats analysis (MLVA) by a distinct profile. Outbreak investigations were initiated independently in the two countries. In Denmark, a total of 37 cases were identified, and multiple findings of the outbreak strain in pork and pigs within the same supply chain led to the identification of pork in various forms as the source. In Norway, ten cases were identified, and the outbreak investigation quickly indicated meat bought in Sweden as the probable source and the Swedish authorities were alerted. Investigations in Sweden identified four human cases and two isolates from minced meat with the distinct profile. Subsequent trace-back of the meat showed that it most likely originated from Denmark. Through international alert from Norway on 19 December, it became clear that the Danish and Norwegian outbreak strains were identical and, later on, that the source of the outbreaks in all three countries could be traced back to Danish pork. MLVA was instrumental in linking the outbreaks in the different countries and tracing the source. This outbreak illustrates that good international communication channels, early alerting mechanisms, inter-sectoral collaboration between public health and food safety authorities and harmonised molecular typing tools are important for effective identification and management of cross-border outbreaks. Differences in legal requirements for food safety in neighbouring countries may be a challenge in terms of communication with consumers in areas where cross-border shopping is common.

  17. An outbreak of Burkholderia stabilis colonization in a nasal ward.

    Science.gov (United States)

    Wang, Lijun; Wang, Mei; Zhang, Junyi; Wu, Wei; Lu, Yuan; Fan, Yanyan

    2015-04-01

    The aim of this study was to describe an outbreak of Burkholderia stabilis colonization among patients in a nasal ward. Multilocus sequence typing (MLST) was used for the molecular typing of B. stabilis isolates. Microbiological records were reviewed to delineate the colonization outbreak period. One hundred seventy-one cultures of environment and equipment samples from the nasal ward were performed to trace the source of contamination. Infection control measures were taken in order to end the outbreak. All B. stabilis isolates were identified as a new MLST type, ST821. A total of 53 patients carried this B. stabilis in the nasal ward between March and September 2013, which was defined as the outbreak period. The source of the colonization was not determined because all environment cultures were negative for Burkholderia cepacia complex. No further B. stabilis carriers have been found in the ward since the implementation of interventions. Attention must be paid to asymptomatic colonization in order to identify outbreaks early. Copyright © 2015 The Authors. Published by Elsevier Ltd.. All rights reserved.

  18. Diphtheria outbreak with high mortality in northeastern Nigeria.

    Science.gov (United States)

    Besa, N C; Coldiron, M E; Bakri, A; Raji, A; Nsuami, M J; Rousseau, C; Hurtado, N; Porten, K

    2014-04-01

    SUMMARY A diphtheria outbreak occurred from February to November 2011 in the village of Kimba and its surrounding settlements, in Borno State, northeastern Nigeria. We conducted a retrospective outbreak investigation in Kimba village and the surrounding settlements to better describe the extent and clinical characteristics of this outbreak. Ninety-eight cases met the criteria of the case definition of diphtheria, 63 (64.3%) of whom were children aged diphtheria. None of the 98 cases received diphtheria antitoxin, penicillin, or erythromycin during their illness. The overall case-fatality ratio was 21.4%, and was highest in children aged 0-4 years (42.9%). Low rates of immunization, delayed clinical recognition of diphtheria and absence of treatment with antitoxin and appropriate antibiotics contributed to this epidemic and its severity.

  19. A Study of 279 General Outbreaks of Gastrointestinal Infection in the North-East Region of England

    Science.gov (United States)

    Tebbutt, Grahame M.; Wilson, Deborah; Holtby, Ian

    2009-01-01

    All outbreaks of infectious intestinal disease reported to the authorities were entered on a computer database with outbreak control teams being established to investigate larger or more significant incidents. The outbreak database and, when set up, the notes of outbreak team meetings were examined for the 279 outbreaks reported in a three-year period (2003–2005). Faeces specimens submitted as part of an outbreak were examined for microbial pathogens and the results cross-matched to the outbreak number. Almost half of the general outbreaks reported (137) occurred in long-term care facilities for the elderly, 51 outbreaks were recorded in hospitals and 31 occurred in the wider community. In 76 outbreaks no specimen was logged. A microbial cause was confirmed in about one-third of outbreaks, with noroviruses being the most common (19%). Salmonellas accounted for 12 of the 21 community outbreaks linked to social events and all were foodborne. Suggestions for improving notification and surveillance are discussed. PMID:19440398

  20. Controlling pandemic flu: the value of international air travel restrictions.

    Directory of Open Access Journals (Sweden)

    Joshua M Epstein

    2007-05-01

    Full Text Available Planning for a possible influenza pandemic is an extremely high priority, as social and economic effects of an unmitigated pandemic would be devastating. Mathematical models can be used to explore different scenarios and provide insight into potential costs, benefits, and effectiveness of prevention and control strategies under consideration.A stochastic, equation-based epidemic model is used to study global transmission of pandemic flu, including the effects of travel restrictions and vaccination. Economic costs of intervention are also considered. The distribution of First Passage Times (FPT to the United States and the numbers of infected persons in metropolitan areas worldwide are studied assuming various times and locations of the initial outbreak. International air travel restrictions alone provide a small delay in FPT to the U.S. When other containment measures are applied at the source in conjunction with travel restrictions, delays could be much longer. If in addition, control measures are instituted worldwide, there is a significant reduction in cases worldwide and specifically in the U.S. However, if travel restrictions are not combined with other measures, local epidemic severity may increase, because restriction-induced delays can push local outbreaks into high epidemic season. The per annum cost to the U.S. economy of international and major domestic air passenger travel restrictions is minimal: on the order of 0.8% of Gross National Product.International air travel restrictions may provide a small but important delay in the spread of a pandemic, especially if other disease control measures are implemented during the afforded time. However, if other measures are not instituted, delays may worsen regional epidemics by pushing the outbreak into high epidemic season. This important interaction between policy and seasonality is only evident with a global-scale model. Since the benefit of travel restrictions can be substantial while

  1. Cold urticaria: inhibition of cold-induced histamine release by doxantrazole.

    Science.gov (United States)

    Bentley-Phillips, C B; Eady, R A; Greaves, M W

    1978-10-01

    Thirteen patients with cold urticaria were studied to assess the effect of the systemic drug doxantrazole, which has actions resembling disodium cromoglycate, on cold evoked histamine release. The patients, all of whom developed an immediate local whealing response after cooling of the forearm, demonstrated release of histamine into venous blood draining that forearm. Following doxantrazole treatment, significant suppression of histamine release occurred. In some but not all patients this was accompanied by diminution of urtication in response to cooling. A double-blind study was carried out in 3 subjects, all of whom showed diminished cold-stimulated histamine release after doxantrazole. Two of these showed clinical improvement. Doxantrazole had no effect on erythema due to intradermal histamine, but did suppress the erythematous reaction to intradermal injection of compound 48/80. Our results suggest that doxantrazole or related anti-allergic agents might be useful in the treatment of cold urticaria.

  2. New counter flow heat exchanger designed for ventilation systems in cold climates

    DEFF Research Database (Denmark)

    Kragh, Jesper; Rose, Jørgen; Nielsen, Toke Rammer

    2007-01-01

    In cold climates, mechanical ventilation systems with highly efficient heat recovery will experience problems with condensing water from the extracted humid indoor air. If the condensed water changes to ice in the heat exchanger, the airflow rate will quickly fall due to the increasing pressure...... problem is therefore desirable. In this paper, the construction and test measurements of a new counter flow heat exchanger designed for cold climates are presented. The developed heat exchanger is capable of continuously defrosting itself without using supplementary heating. Other advantages...... of the developed beat exchanger are low pressure loss, cheap materials and a simple construction. The disadvantage is that the exchanger is big compared with other heat exchangers. In this paper, the new heat exchanger's efficiency is calculated theoretically and measured experimentally. The experiment shows...

  3. An outbreak of epidemic keratoconjunctivitis at an outpatient ophthalmology clinic

    Directory of Open Access Journals (Sweden)

    Timothy J Doyle

    2010-12-01

    Full Text Available Epidemic keratoconjunctivitis (EKC is an acute eye infection caused by adenovirus. We investigated an outbreak of EKC at an outpatient ophthalmology practice in the context of a suspected community wide increase in EKC activity. A site visit was made to the facility reporting the outbreak. A line list was created of patients clinically diagnosed with EKC at the practice during the previous 5 months. A questionnaire was faxed to all other licensed ophthalmologists in the county regarding recent EKC activity in their facility. Descriptive data analyses were conducted. The outbreak facility reported 37 patients clinically diagnosed with EKC during the previous 5 months. In addition, the single ophthalmologist at the practice also had symptoms compatible with EKC during the outbreak period. Specimens were collected on 4 patients and all were positive for adenovirus serotype 8. Forty percent of ophthalmologists surveyed in the county saw at least one EKC patient in the previous 3 months, and 20% reported a perceived increase in EKC activity in recent months over normal seasonal patterns. The outbreak at the facility likely began as part of a widespread community increase in EKC that may have been amplified at the facility through nosocomial transmission. Medical providers experiencing increases in EKC activity above seasonally expected norms should contact their public health department for assistance with etiologic diagnoses and outbreak control.

  4. Outbreaks of gastroenteritis linked to lettuce, Denmark, January 2010

    DEFF Research Database (Denmark)

    Ethelberg, S.; Lisby, M.; Bottiger, B.

    2010-01-01

    At least 11 linked outbreaks of gastroenteritis with a total of 260 cases have occurred in Denmark in mid January 2010. Investigations showed that the outbreaks were caused by norovirus of several genotypes and by enterotoxigenic Escherichia coli. Lettuce of the lollo bionda type grown in France...

  5. 77 FR 43117 - Meeting of the Cold War Advisory Committee for the Cold War Theme Study

    Science.gov (United States)

    2012-07-23

    ... the Cold War Advisory Committee for the Cold War Theme Study AGENCY: National Park Service, Interior... Committee Act, 5 U.S.C. Appendix, that the Cold War Advisory Committee for the Cold War Theme Study will... National Park Service (NPS) concerning the Cold War Theme Study. DATES: The teleconference meeting will be...

  6. Mining the key predictors for event outbreaks in social networks

    Science.gov (United States)

    Yi, Chengqi; Bao, Yuanyuan; Xue, Yibo

    2016-04-01

    It will be beneficial to devise a method to predict a so-called event outbreak. Existing works mainly focus on exploring effective methods for improving the accuracy of predictions, while ignoring the underlying causes: What makes event go viral? What factors that significantly influence the prediction of an event outbreak in social networks? In this paper, we proposed a novel definition for an event outbreak, taking into account the structural changes to a network during the propagation of content. In addition, we investigated features that were sensitive to predicting an event outbreak. In order to investigate the universality of these features at different stages of an event, we split the entire lifecycle of an event into 20 equal segments according to the proportion of the propagation time. We extracted 44 features, including features related to content, users, structure, and time, from each segment of the event. Based on these features, we proposed a prediction method using supervised classification algorithms to predict event outbreaks. Experimental results indicate that, as time goes by, our method is highly accurate, with a precision rate ranging from 79% to 97% and a recall rate ranging from 74% to 97%. In addition, after applying a feature-selection algorithm, the top five selected features can considerably improve the accuracy of the prediction. Data-driven experimental results show that the entropy of the eigenvector centrality, the entropy of the PageRank, the standard deviation of the betweenness centrality, the proportion of re-shares without content, and the average path length are the key predictors for an event outbreak. Our findings are especially useful for further exploring the intrinsic characteristics of outbreak prediction.

  7. Development of the RRR Cold Neutron Source facility

    International Nuclear Information System (INIS)

    Masriera, N.; Lecot, C.; Hergenreder, D.; Lovotti, O.; Serebrov, A.; Zakharov, A.; Mityukhlyaev, V.

    2003-01-01

    This paper describes some general design issues on the Cold Neutron Source (CNS) of the Replacement Research Reactor (RRR) for the Australian Nuclear Science and Technology Organisation (ANSTO). The description covers different aspects of the design: the requirements that lead to an innovative design, the overall design itself and the definition of a technical approach in order to develop the necessary design solutions. The RRR-CNS has liquid Deuterium (LD2) moderator, sub-cooled to ensure maximum moderation efficiency, flowing within a closed natural circulation Thermosiphon loop. The Thermosiphon is surrounded by a CNS Vacuum Containment made of zirconium alloy, that provides thermal insulation and a multiple barriers scheme to prevent Deuterium from mixing with water or air. Consistent with international practice, this vessel is designed to withstand any hypothetical energy reaction should Deuterium and air mix in its interior. The applied design approach allows ensuring that the RRR-CNS, in spite of being innovative, will meet all the design, performance and quality requirements. (author)

  8. Development of Cold Neutron Activation Station at HANARO Cold Neutron Source

    International Nuclear Information System (INIS)

    Sun, G. M.; Hoang, S. M. T.; Moon, J. H.; Chung, Y. S.; Cho, S. J.; Lee, K. H.; Park, B. G.; Choi, H. D.

    2012-01-01

    A new cold neutron source at the HANARO Research Reactor had been constructed in the framework of a five-year project, and ended in 2009. It has seven neutron guides, among which five guides were already allocated for a number of neutron scattering instruments. A new two-year project to develop a Cold Neutron Activation Station (CONAS) was carried out at the two neutron guides since May 2010, which was supported by the program of the Ministry of Education, Science and Technology, Korea. Fig. 1 shows the location of CONAS. CONAS is a complex facility including several radioanalytical instruments utilizing neutron capture reaction to analyze elements in a sample. It was designed to include three instruments like a CN-PGAA (Cold Neutron - Prompt Gamma Activation Analysis), a CN-NIPS (Cold Neutron - Neutron Induced Pair Spectrometer), and a CN-NDP (Cold Neutron - Neutron-induced prompt charged particle Depth Profiling). Fig. 2 shows the conceptual configuration of the CONAS concrete bioshield and the instruments. CN-PGAA and CN-NIPS measure the gamma-rays promptly emitted from the sample after neutron capture, whereas CN-NDP is a probe to measure the charged particles emitted from the sample surface after neutron capture. For this, we constructed two cold neutron guides called CG1 and CG2B guides from the CNS

  9. Investigation of outbreaks of Pneumocystis jirovecii pneumonia in two Scottish renal units.

    Science.gov (United States)

    Inkster, T; Dodd, S; Gunson, R; Imrie, L; Spalding, E; Packer, S; Deighan, C; Daly, C; Coia, J; Imtiaz, T; McGuffie, C; Wilson, R; Bal, A M

    2017-06-01

    Pneumocystis jirovecii is recognized as an opportunistic pathogen. In recent years, human-to-human transmission of P. jirovecii has been demonstrated. However, outbreaks of P. jirovecii infections are not well defined because the epidemiological setting that facilitates transmission is not fully understood. This article describes two outbreaks of P. jirovecii pneumonia (PCP) in renal transplant patients in the West of Scotland. In total, 25 patients in two geographically contiguous locations were affected. Allele B was identified as the dominant type, along with allele A3. It was not possible to determine the exact reason for clustering of cases, although the outpatient clinic setting featured in one of the outbreaks. The outbreaks ceased with the use of trimethoprim-sulphamethoxazole prophylaxis; the target populations that received prophylaxis were different in the two outbreaks. Infection control teams should be alert to the possibility of outbreaks of PCP. Crown Copyright © 2016. Published by Elsevier Ltd. All rights reserved.

  10. A comprehensive database of the geographic spread of past human Ebola outbreaks.

    Science.gov (United States)

    Mylne, Adrian; Brady, Oliver J; Huang, Zhi; Pigott, David M; Golding, Nick; Kraemer, Moritz U G; Hay, Simon I

    2014-01-01

    Ebola is a zoonotic filovirus that has the potential to cause outbreaks of variable magnitude in human populations. This database collates our existing knowledge of all known human outbreaks of Ebola for the first time by extracting details of their suspected zoonotic origin and subsequent human-to-human spread from a range of published and non-published sources. In total, 22 unique Ebola outbreaks were identified, composed of 117 unique geographic transmission clusters. Details of the index case and geographic spread of secondary and imported cases were recorded as well as summaries of patient numbers and case fatality rates. A brief text summary describing suspected routes and means of spread for each outbreak was also included. While we cannot yet include the ongoing Guinea and DRC outbreaks until they are over, these data and compiled maps can be used to gain an improved understanding of the initial spread of past Ebola outbreaks and help evaluate surveillance and control guidelines for limiting the spread of future epidemics.

  11. Support for cold neutron utilization

    International Nuclear Information System (INIS)

    Lee, Kye Hong; Han, Young Soo; Choi, Sungmin; Choi, Yong; Kwon, Hoon; Lee, Kwang Hee

    2012-06-01

    - Support for experiments by users of cold neutron scattering instrument - Short-term training of current and potential users of cold neutron scattering instrument for their effective use of the instrument - International collaboration for advanced utilization of cold neutron scattering instruments - Selection and training of qualified instrument scientists for vigorous research endeavors and outstanding achievements in experiments with cold neutron - Research on nano/bio materials using cold neutron scattering instruments - Bulk nano structure measurement using small angle neutron scattering and development of analysis technique

  12. Air-cleaning apparatus

    International Nuclear Information System (INIS)

    Howard, A.G.

    1981-01-01

    An air-cleaning, heat-exchange apparatus includes a main housing portion connected by means of an air inlet fan to the kitchen exhaust stack of a restaurant. The apparatus includes a plurality of heat exchangers through which a heat-absorptive fluid is circulated, simultaneously, by means of a suitable fluid pump. These heat exchangers absorb heat from the hot exhaust gas, out of the exhaust stack of the restaurant, which flows over and through these heat exchangers and transfers this heat to the circulating fluid which communicates with remote heat exchangers. These remote heat exchangers further transfer this heat to a stream of air, such as that from a cold-air return duct for supplementing the conventional heating system of the restaurant. Due to the fact that such hot exhaust gas is heavily grease laden , grease will be deposited on virtually all internal surfaces of the apparatus which this exhaust gas contacts. Consequently, means are provided for spraying these contacted internal surfaces , as well as the hot exhaust gas itself, with a detergent solution in which the grease is soluble, thereby removing grease buildup from these internal surfaces

  13. No Sense in Dwelling on the Past?: The Fate of the US Air Force’s German Air Force Monograph Project, 1952-69

    Science.gov (United States)

    2011-04-01

    the Air Force during the early Cold War. Still, cooperative historical work proved to be an inexpen- sive and unexpected way of cementing the...thesis (the Condor Legion, the Luftwaffe force dispatched to aid Francisco Franco during the Spanish Civil War) and his fluency in German made him well...educa- tional books to the Bundesluftwaffe, which was based on the American model. The bonds cemented between West German and American air officers

  14. Cold period in the Northern Europe in the past (about 8200 years ago: analysis of empirical data and possible causes

    Directory of Open Access Journals (Sweden)

    I. I. Borzenkova

    2017-01-01

    Full Text Available Cold episode in Northern Europe happened about 8200 years ago was known for a relatively long time, mainly due to paleobotanical (palynological data obtained from analysis of lake and peat sediments. Detailed analysis of ice cores from the Greenland holes GRIP, GISP2, and NGRIP with a time resolution of about 10 years made possible to refine the duration and characteristics of the time structure of this cold period. This cooling lasted for approximately 160 yr. Spore-pollen analysis of lake sediments in Northern Europe (Sweden, Finland, Denmark, Germany, the North and North-West of Russia and deep-sea cores of the North Atlantic showed that the mean annual air temperature during the maximum stage of the cooling was reduced by 1–2 °C, and in some areas by more than 3 °C. The cold spread from the coast of the North Atlantic into the European continent and manifested itself mostly in Sweden, Finland, the Baltic States, and to a lesser extent in the North-West and West of the Russian Federation. In the central Russia and North of 70°N the cooling was weak or absent. The question about a nature of this cold event and other cold spells in Late Glaciation, known as the cold of the early, middle and late Dryas, is widely discussed in the scientific literature. Most of scientists accept a hypothesis proposed more than 20 years ago, that the reduction of air temperatures in regions immediately adjacent to the North Atlantic was caused by the large volume of melt water discharged into the ocean as a result of disintegration and melting of ice-sheets. Climate models that take into account these effects allow estimating a decrease in the air and sea surface temperature due to freshening (desalination of the upper ocean layer, and this confirms that the greatest decrease in temperature should be observed in the regions directly adjacent to the ocean. The increase in global temperature over the last 30 years is estimated to be 0.8 ± 0.2

  15. Outbreak of Diarrhetic Shellfish Poisoning Associated with Mussels, British Columbia, Canada

    Science.gov (United States)

    Taylor, Marsha; McIntyre, Lorraine; Ritson, Mark; Stone, Jason; Bronson, Roni; Bitzikos, Olga; Rourke, Wade; Galanis, Eleni

    2013-01-01

    In 2011, a Diarrhetic Shellfish Poisoning (DSP) outbreak occurred in British Columbia (BC), Canada that was associated with cooked mussel consumption. This is the first reported DSP outbreak in BC. Investigation of ill individuals, traceback of product and laboratory testing for toxins were used in this investigation. Sixty-two illnesses were reported. Public health and food safety investigation identified a common food source and harvest area. Public health and regulatory agencies took actions to recall product and notify the public. Shellfish monitoring program changes were implemented after the outbreak. Improved response and understanding of toxin production will improve management of future DSP outbreaks. PMID:23697950

  16. An outbreak of food poisoning among children attending an ...

    African Journals Online (AJOL)

    Objectives. To describe an outbreak of food. poisoning at a major international sports event in Johannesburg and to determine the likely cause and source of the outbreak. Design. A descriptive, case-control study. Setting. An international sports event in Johannesburg. Methods. A questionnaire survey of involved children ...

  17. Molecular Investigation into a Malaria Outbreak in Cusco, Peru: Plasmodium falciparum BV1 Lineage is Linked to a Second Outbreak in Recent Times

    Science.gov (United States)

    Okoth, Sheila Akinyi; Chenet, Stella M.; Arrospide, Nancy; Gutierrez, Sonia; Cabezas, Cesar; Matta, Jose Antonio; Udhayakumar, Venkatachalam

    2016-01-01

    In November 2013, a Plasmodium falciparum malaria outbreak of 11 cases occurred in Cusco, southern Peru, where falciparum malaria had not been reported since 1946. Although initial microscopic diagnosis reported only Plasmodium vivax infection in each of the specimens, subsequent examination by the national reference laboratory confirmed P. falciparum infection in all samples. Molecular typing of four available isolates revealed identity as the B-variant (BV1) strain that was responsible for a malaria outbreak in Tumbes, northern Peru, between 2010 and 2012. The P. falciparum BV1 strain is multidrug resistant, can escape detection by PfHRP2-based rapid diagnostic tests, and has contributed to two malaria outbreaks in Peru. This investigation highlights the importance of accurate species diagnosis given the potential for P. falciparum to be reintroduced to regions where it may have been absent. Similar molecular epidemiological investigations can track the probable source(s) of outbreak parasite strains for malaria surveillance and control purposes. PMID:26483121

  18. Mood and selective attention in the cold: the effect of interval versus continuous exercise.

    Science.gov (United States)

    Muller, Matthew D; Muller, Sarah M; Kim, Chul-Ho; Ryan, Edward J; Gunstad, John; Glickman, Ellen L

    2011-07-01

    Both mood and cognitive function are altered in cold environments. Body warming through exercise may improve Stroop interference score and lessen total negative mood. The purpose of this study was to determine the effect of equal caloric bouts of interval (INT) and continuous (CONT) exercise on mood and selective attention in the cold. Eleven young men underwent two experimental trials in 5°C air. Both trials consisted of 90 min acute cold exposure (ACE), 30 min exercise (INT vs. CONT), and 60 min recovery (REC). The Profile of Mood States (POMS) and Stroop Color Word Test (SCWT) were administered at four time points. Mean body temperature decreased during ACE, increased during exercise, and decreased during REC. Repeated measures analysis of variance revealed a main effect for time for several of the POMS sub scores. In particular, negative mood was significantly decreased after exercise relative to ACE and then significantly increased during REC. Further, CONT appears to be more effective than INT at decreasing negative mood. Components of the SCWT supported both the arousal and distraction theories for simple perception, but no significant effects were shown for the interference score. In the cold, exercise decreases negative mood but does not appear to affect selective attention. Further mechanistic studies could determine the best mode and intensity of exercise for improving cognitive function in the cold.

  19. Polio outbreak investigation and response in Somalia, 2013.

    Science.gov (United States)

    Kamadjeu, Raoul; Mahamud, Abdirahman; Webeck, Jenna; Baranyikwa, Marie Therese; Chatterjee, Anirban; Bile, Yassin Nur; Birungi, Julianne; Mbaeyi, Chukwuma; Mulugeta, Abraham

    2014-11-01

    For >2 decades, conflicts and recurrent natural disasters have maintained Somalia in a chronic humanitarian crisis. For nearly 5 years, 1 million children polio once again. A case of acute flaccid paralysis (AFP) was defined as a child Polio cases were defined as AFP cases with stool specimens positive for WPV. From 9 May to 31 December 2013, 189 cases of WPV type 1 (WPV1) were reported from 46 districts of Somalia; 42% were from Banadir region (Mogadishu), 60% were males, and 93% were polio cases belonged to cluster N5A, which is known to have been circulating in northern Nigeria since 2011. In response to the outbreak, 8 supplementary immunization activities were conducted with oral polio vaccine (OPV; trivalent OPV was used initially, followed subsequently by bivalent OPV) targeting various age groups, including children aged polio outbreak erupted after a polio-free period of >6 years (the last case was reported in March 2007). Somalia interrupted indigenous WPV transmission in 2002, was removed from the list of polio-endemic countries a year later, and has since demonstrated its ability to control polio outbreaks resulting from importation. This outbreak reiterates that the threat of large polio outbreaks resulting from WPV importation will remain constant unless polio transmission is interrupted in the remaining polio-endemic countries. Published by Oxford University Press on behalf of the Infectious Diseases Society of America 2014. This work is written by (a) US Government employee(s) and is in the public domain in the US.

  20. Outbreaks following wild poliovirus importations --- Europe, Africa, and Asia, January 2009-September 2010.

    Science.gov (United States)

    2010-11-05

    The Global Polio Eradication Initiative (GPEI) began in 1988. By 2006, indigenous transmission of wild poliovirus (WPV) had been interrupted in all but four countries (Afghanistan, India, Nigeria, and Pakistan). However, outbreaks following WPV importations into previously polio-free countries remain an ongoing risk until polio is eradicated. The GPEI Strategic Plan for 2010-2012 set the following two goals for outbreak control: 1) end outbreaks occurring in 2009 by mid-2010 and 2) end outbreaks occurring during 2010 to mid-2012 within 6 months of confirmation. This report describes new outbreaks that have occurred in the World Health Organization (WHO) European Region and updates previous reports on the status of outbreaks in Africa and Asia. In 2010, the first WPV importation into the European Region since the region was declared polio-free in 2002 resulted in 476 confirmed cases: 458 in Tajikistan, 14 in Russia, three in Turkmenistan, and one in Kazakhstan. In Africa and Asia, 11 new importations into six countries were observed in 2010; 30 WPV importations that occurred during 2008-2009 resulted in 215 cases in 15 African countries during 2009-2010. An outbreak is considered interrupted if 6 months have elapsed since the latest confirmed case and surveillance performance indicators meet WHO standards. All 2009 outbreaks in Africa appear to have been interrupted, and 2010 outbreaks in three countries appear to have been interrupted. Maintaining high routine vaccination coverage and sensitive surveillance at all times and rapidly instituting additional immunization programs to control outbreaks are key to limiting and stopping the spread of WPV.

  1. Cold Vacuum Drying Facility Condensate Collection System Design Description. System 19

    International Nuclear Information System (INIS)

    PITKOFF, C.C.

    2000-01-01

    The Cold Vacuum Drying (CVD) Facility of Spent Nuclear Fuel (SNF) provides required process systems, supporting equipment, and facilities to support the SNF Project mission. This system design description (SDD) addresses the Condensate Collection System (CCS). This is a general service system. The CCS begins at the condensate outlet of the general process air-handling unit (AHU) and the condensate outlets for the active process bays AHUs. The system terminates at each condensate collection tank (5 total)

  2. Genomic epidemiology of the Escherichia coli O104:H4 outbreaks in Europe, 2011

    DEFF Research Database (Denmark)

    Grad, Yonatan H; Lipsitch, Marc; Feldgarden, Michael

    2012-01-01

    The degree to which molecular epidemiology reveals information about the sources and transmission patterns of an outbreak depends on the resolution of the technology used and the samples studied. Isolates of Escherichia coli O104:H4 from the outbreak centered in Germany in May-July 2011, and the ...... that purged diversity in the German isolates, variation in mutation rates in the two E. coli outbreak populations, or uneven distribution of diversity in the seed populations that led to each outbreak....... remarkably little diversity, with only two single nucleotide polymorphisms (SNPs) found in isolates from four individuals. Surprisingly, we found much greater diversity (19 SNPs) in isolates from seven individuals infected in the French outbreak. The German isolates form a clade within the more diverse...... French outbreak strains. Moreover, five isolates derived from a single infected individual from the French outbreak had extremely limited diversity. The striking difference in diversity between the German and French outbreak samples is consistent with several hypotheses, including a bottleneck...

  3. Reported waterborne outbreaks of gastrointestinal disease in Australia are predominantly associated with recreational exposure.

    Science.gov (United States)

    Dale, Katie; Kirk, Martyn; Sinclair, Martha; Hall, Robert; Leder, Karin

    2010-10-01

    To examine the frequency and circumstances of reported waterborne outbreaks of gastroenteritis in Australia. Examination of data reported to OzFoodNet between 2001 and 2007. During these seven years, 6,515 gastroenteritis outbreaks were reported to OzFoodNet, most of which were classified as being transmitted person-to-person or from an unknown source. Fifty-four (0.83%) outbreaks were classified as either 'waterborne' or 'suspected waterborne', of which 78% (42/54) were attributed to recreational water and 19% (10/54) to drinking water. Of the drinking water outbreaks, implicated pathogens were found on all but one occasion and included Salmonella sp. (five outbreaks), Campylobacter jejuni (three outbreaks) and Giardia (one outbreak). There have been few waterborne outbreaks detected in Australia, and most of those reported have been associated with recreational exposure. However, there are difficulties in identifying and categorising gastroenteritis outbreaks, as well as in obtaining microbiological and epidemiological evidence, which can result in misclassification or underestimation of water-associated events. Gastroenteritis surveillance data show that, among reported water-associated gastroenteritis outbreaks in Australia, recreational exposure is currently more common than a drinking water source. However, ongoing surveillance for waterborne outbreaks is important, especially as drought conditions may necessitate replacement of conventional drinking water supplies with alternative water sources, which could incur potential for new health risks. © 2010 The Authors. Journal Compilation © 2010 Public Health Association of Australia.

  4. The Nav1.9 Channel Is a Key Determinant of Cold Pain Sensation and Cold Allodynia

    Directory of Open Access Journals (Sweden)

    Stéphane Lolignier

    2015-05-01

    Full Text Available Cold-triggered pain is essential to avoid prolonged exposure to harmfully low temperatures. However, the molecular basis of noxious cold sensing in mammals is still not completely understood. Here, we show that the voltage-gated Nav1.9 sodium channel is important for the perception of pain in response to noxious cold. Nav1.9 activity is upregulated in a subpopulation of damage-sensing sensory neurons responding to cooling, which allows the channel to amplify subthreshold depolarizations generated by the activation of cold transducers. Consequently, cold-triggered firing is impaired in Nav1.9−/− neurons, and Nav1.9 null mice and knockdown rats show increased cold pain thresholds. Disrupting Nav1.9 expression in rodents also alleviates cold pain hypersensitivity induced by the antineoplastic agent oxaliplatin. We conclude that Nav1.9 acts as a subthreshold amplifier in cold-sensitive nociceptive neurons and is required for the perception of cold pain under normal and pathological conditions.

  5. THE COLD AND DARK PROCESS AT THE SAVANNAH RIVER SITE

    International Nuclear Information System (INIS)

    Gilmour, J; William Austin, W; Cathy Sizemore, C

    2007-01-01

    The deactivation and decommissioning (D and D) of a facility exposes D and D workers to numerous hazards. One of the more serious hazards is coming into contact to hazardous energy sources (e.g. electrical, pressurized steam). At the Savannah River Site (SRS) a formal process for identifying and eliminating sources of hazardous energy was developed and is called ''Cold and Dark''. Several ''near miss'' events involving cutting of energized conductors during D and D work in buildings thought to be isolated identified the need to have a formal process to identify and isolate these potentially hazardous systems. This process was developed using lessons learned from D and D activities at the Rocky Flats Environmental Technology Site (Rocky Flats) in Colorado. The Cold and Dark process defines an isolation boundary (usually a building perimeter) and then systematically identifies all of the penetrations through this boundary. All penetrations that involve hazardous energy sources are then physically air-gapped. The final product is a documented declaration of isolation performed by a team involving operations, engineering, and project management. Once the Cold and Dark declaration is made for a building work can proceed without the usual controls used in an operational facility (e.g. lockout/tagout, arc flash PPE). It is important to note that the Cold and Dark process does not remove all hazards from a facility. Work planning and controls still need to address hazards that can be present from such things as chemicals, radiological contamination, residual liquids, etc., as well as standard industrial hazards

  6. The Recent Atlantic Cold Anomaly: Causes, Consequences, and Related Phenomena

    Science.gov (United States)

    Josey, Simon A.; Hirschi, Joel J.-M.; Sinha, Bablu; Duchez, Aurélie; Grist, Jeremy P.; Marsh, Robert

    2018-01-01

    Cold ocean temperature anomalies have been observed in the mid- to high-latitude North Atlantic on interannual to centennial timescales. Most notably, a large region of persistently low surface temperatures accompanied by a sharp reduction in ocean heat content was evident in the subpolar gyre from the winter of 2013-2014 to 2016, and the presence of this feature at a time of pervasive warming elsewhere has stimulated considerable debate. Here, we review the role of air-sea interaction and ocean processes in generating this cold anomaly and place it in a longer-term context. We also discuss the potential impacts of surface temperature anomalies for the atmosphere, including the North Atlantic Oscillation and European heat waves; contrast the behavior of the Atlantic with the extreme warm surface event that occurred in the North Pacific over a similar timescale; and consider the possibility that these events represent a response to a change in atmospheric planetary wave forcing.

  7. Cold temperatures increase cold hardiness in the next generation Ophraella communa beetles.

    Directory of Open Access Journals (Sweden)

    Zhong-Shi Zhou

    Full Text Available The leaf beetle, Ophraella communa, has been introduced to control the spread of the common ragweed, Ambrosia artemisiifolia, in China. We hypothesized that the beetle, to be able to track host-range expansion into colder climates, can phenotypically adapt to cold temperatures across generations. Therefore, we questioned whether parental experience of colder temperatures increases cold tolerance of the progeny. Specifically, we studied the demography, including development, fecundity, and survival, as well as physiological traits, including supercooling point (SCP, water content, and glycerol content of O. communa progeny whose parents were maintained at different temperature regimes. Overall, the entire immature stage decreased survival of about 0.2%-4.2% when parents experienced cold temperatures compared to control individuals obtained from parents raised at room temperature. However, intrinsic capacity for increase (r, net reproductive rate (R 0 and finite rate of increase (λ of progeny O. communa were maximum when parents experienced cold temperatures. Glycerol contents of both female and male in progeny was significantly higher when maternal and paternal adults were cold acclimated as compared to other treatments. This resulted in the supercooling point of the progeny adults being significantly lower compared to beetles emerging from parents that experienced room temperatures. These results suggest that cold hardiness of O. communa can be promoted by cold acclimation in previous generation, and it might counter-balance reduced survival in the next generation, especially when insects are tracking their host-plants into colder climates.

  8. Outbreak of Vibrio parahaemolyticus Sequence Type 120, Peru, 2009.

    Science.gov (United States)

    Gonzalez-Escalona, Narjol; Gavilan, Ronnie G; Toro, Magaly; Zamudio, Maria L; Martinez-Urtaza, Jaime

    2016-07-01

    In 2009, an outbreak of Vibrio parahaemolyticus occurred in Piura, Cajamarca, Lambayeque, and Lima, Peru. Whole-genome sequencing of clinical and environmental samples from the outbreak revealed a new V. parahaemolyticus clone. All the isolates identified belonged to a single clonal complex described exclusively in Asia before its emergence in Peru.

  9. Additional value of typing Noroviruses in gastroenteritis outbreaks in Amsterdam, The Netherlands

    NARCIS (Netherlands)

    Koek, A. G.; Bovée, L. P. M. J.; van den Hoek, J. A. R.; Bos, A. J.; Bruisten, S. M.

    2006-01-01

    In Amsterdam, 17 of the 55 gastroenteritis (GI) outbreaks reported from January 2002 to May 2003 were confirmed to be caused by noroviruses (NV). In this study, we describe the molecular epidemiology of a group of nine outbreaks associated with a catering firm and two outbreaks, 5 months apart, in

  10. PHYSIOLOGICAL AND LEUKOCYTE SUBSET RESPONSES TO EXERCISE AND COLD EXPOSURE IN COLD-ACCLIMATIZED SKATERS

    Directory of Open Access Journals (Sweden)

    K. Kim

    2014-07-01

    Full Text Available We investigated physiological responses and changes in circulating immune cells following exercise in cold and thermoneutral conditions. Participants were short track skaters (n=9 who were acclimatized to cold conditions, and inline skaters (n=10 who were not acclimatized. All skaters were young, and skating at a recreational level three days per week for at least one year. Using a cross-over design, study variables were measured during 60 min of submaximal cycling (65% ·VO2max in cold (ambient temperature: 5±1°C, relative humidity: 41±9% and thermoneutral conditions (ambient temperature: 21±1°C, relative humidity: 35±5%. Heart rate, blood lactate and tympanic temperature were measured at rest, during exercise and recovery. Plasma cortisol, calprotectin and circulating blood cell numbers were measured before and after 60 min of cold or thermoneutral conditions, and during recovery from exercise. Heart rate was lower in both groups during exercise in cold versus thermoneutral conditions (P<0.05. The increase in total leukocytes during recovery was primarily due to an increase in neutrophils in both groups. The cold-acclimatized group activated neutrophils after exercise in cold exposure, whereas the non-acclimatized group activated lymphocyte and cortisol after exercise in cold exposure. Lymphocyte subsets significantly changed in both groups over time during recovery as compared to rest. Immediately after exercise in both groups, CD16+ and CD69+ cells were elevated compared to rest or before exercise in both conditions. Acclimatization to exercise in the cold does not appear to influence exercise-induced immune changes in cold conditions, with the possible exception of neutrophils, lymphocytes and cortisol concentration.

  11. Analysis of epidemiological data of foodborne outbreak reported in Iran

    Directory of Open Access Journals (Sweden)

    Mohammad Mehdi Soltan Dallal

    2015-02-01

    Conclusion: The knowledge of bacterial agent of foodborne diseases and determination of antimicrobial resistance pattern are helpful to reduce the rate of foodborne outbreaks, the cost of treatment. The prevention control of outbreaks is also very important.

  12. Assessment of the response to cholera outbreaks in two districts in Ghana.

    Science.gov (United States)

    Ohene, Sally-Ann; Klenyuie, Wisdom; Sarpeh, Mark

    2016-11-02

    Despite recurring outbreaks of cholera in Ghana, very little has been reported on assessments of outbreak response activities undertaken in affected areas. This study assessed the response activities undertaken in two districts, Akatsi District in Volta Region and Komenda-Edina-Eguafo-Abirem (KEEA) Municipal in Central Region during the 2012 cholera epidemic in Ghana. We conducted a retrospective assessment of the events, strengths and weaknesses of the cholera outbreak response activities in the two districts making use of the WHO cholera evaluation tool. Information sources included surveillance and facility records, reports and interviews with relevant health personnel involved in the outbreak response from both district health directorates and health facilities. We collected data on age, sex, area of residence, date of reporting to health facility of cholera cases, district population data and information on the outbreak response activities and performed descriptive analyses of the outbreak data by person, time and place. The cholera outbreak in Akatsi was explosive with a high attack rate (AR) of 374/100,000 and case fatality rate (CFR) of 1.2 % while that in KEEA was on a relatively smaller scale AR of 23/100,000 but with a high case fatality rate of 18.8 %. For both districts, we identified multiple strengths in the response to the outbreak including timely notification of the district health officials which triggered prompt investigation of the suspected outbreak facilitating confirmation of cholera and initiation of public health response activities. Others were coordination of the activities by multi-sectoral committees, instituting water, sanitation and hygiene measures and appropriate case management at health facilities. We also found areas that needed improvement in both districts including incomplete surveillance data, sub-optimal community based surveillance considering the late reporting and the deaths in the community and the inadequate

  13. Waterborne norovirus outbreak in a municipal drinking-water supply in Sweden.

    Science.gov (United States)

    Riera-Montes, M; Brus Sjölander, K; Allestam, G; Hallin, E; Hedlund, K-O; Löfdahl, M

    2011-12-01

    During Easter 2009, almost 200 people resident in a small Swedish village fell ill with gastrointestinal symptoms. We conducted a retrospective cohort study and a molecular investigation in order to identify the source of the outbreak. Residents living in households connected to the public water network were at an increased risk of developing disease (relative risk 4·80, 95% confidence interval 1·68-13·73) compared to those with no connection to the public network. Norovirus genotype GI.3 was identified in stool samples from six patients and in a sample from the public water network. Contamination of one of the wells supplying the public water network was thought to be the source of the outbreak. This is a description of a norovirus outbreak linked to a municipal drinking-water supply in Sweden. Information from epidemiological and molecular investigations is of utmost importance to guide outbreak control measures and to prevent future outbreaks.

  14. Identification and control of a poliomyelitis outbreak in Xinjiang, China.

    Science.gov (United States)

    Luo, Hui-Ming; Zhang, Yong; Wang, Xin-Qi; Yu, Wen-Zhou; Wen, Ning; Yan, Dong-Mei; Wang, Hua-Qing; Wushouer, Fuerhati; Wang, Hai-Bo; Xu, Ai-Qiang; Zheng, Jing-Shan; Li, De-Xin; Cui, Hui; Wang, Jian-Ping; Zhu, Shuang-Li; Feng, Zi-Jian; Cui, Fu-Qiang; Ning, Jing; Hao, Li-Xin; Fan, Chun-Xiang; Ning, Gui-Jun; Yu, Hong-Jie; Wang, Shi-Wen; Liu, Da-Wei; Wang, Dong-Yan; Fu, Jian-Ping; Gou, Ai-li; Zhang, Guo-Min; Huang, Guo-Hong; Chen, Yuan-Sheng; Mi, Sha-Sha; Liu, Yan-Min; Yin, Da-Peng; Zhu, Hui; Fan, Xin-Chun; Li, Xin-Lan; Ji, Yi-Xin; Li, Ke-Li; Tang, Hai-Shu; Xu, Wen-Bo; Wang, Yu; Yang, Wei-Zhong

    2013-11-21

    The last case of infection with wild-type poliovirus indigenous to China was reported in 1994, and China was certified as a poliomyelitis-free region in 2000. In 2011, an outbreak of infection with imported wild-type poliovirus occurred in the province of Xinjiang. We conducted an investigation to guide the response to the outbreak, performed sequence analysis of the poliovirus type 1 capsid protein VP1 to determine the source, and carried out serologic and coverage surveys to assess the risk of viral propagation. Surveillance for acute flaccid paralysis was intensified to enhance case ascertainment. Between July 3 and October 9, 2011, investigators identified 21 cases of infection with wild-type poliovirus and 23 clinically compatible cases in southern Xinjiang. Wild-type poliovirus type 1 was isolated from 14 of 673 contacts of patients with acute flaccid paralysis (2.1%) and from 13 of 491 healthy persons who were not in contact with affected persons (2.6%). Sequence analysis implicated an imported wild-type poliovirus that originated in Pakistan as the cause of the outbreak. A public health emergency was declared in Xinjiang after the outbreak was confirmed. Surveillance for acute flaccid paralysis was enhanced, with daily reporting from all public and private hospitals. Five rounds of vaccination with live, attenuated oral poliovirus vaccine (OPV) were conducted among children and adults, and 43 million doses of OPV were administered. Trivalent OPV was used in three rounds, and monovalent OPV type 1 was used in two rounds. The outbreak was stopped 1.5 months after laboratory confirmation of the index case. The 2011 outbreak in China showed that poliomyelitis-free countries remain at risk for outbreaks while the poliovirus circulates anywhere in the world. Global eradication of poliomyelitis will benefit all countries, even those that are currently free of poliomyelitis.

  15. Cold fusion, Alchemist's dream

    International Nuclear Information System (INIS)

    Clayton, E.D.

    1989-09-01

    In this report the following topics relating to cold fusion are discussed: muon catalysed cold fusion; piezonuclear fusion; sundry explanations pertaining to cold fusion; cosmic ray muon catalysed cold fusion; vibrational mechanisms in excited states of D 2 molecules; barrier penetration probabilities within the hydrogenated metal lattice/piezonuclear fusion; branching ratios of D 2 fusion at low energies; fusion of deuterons into 4 He; secondary D+T fusion within the hydrogenated metal lattice; 3 He to 4 He ratio within the metal lattice; shock induced fusion; and anomalously high isotopic ratios of 3 He/ 4 He

  16. Clostridium perfringens in London, July 2009: two weddings and an outbreak.

    OpenAIRE

    Eriksen, J.; Zenner, D.; Anderson, S. R.; Grant, K.; Kumar, D.

    2010-01-01

    : Food poisoning outbreaks caused by Clostridium perfringens enterotoxin occur occasionally in Europe but have become less common in recent years. This paper presents the microbiological and epidemiological results of a large C. perfringens outbreak occurring simultaneously at two weddings that used the same caterer. The outbreak involved several London locations and required coordination across multiple agencies. A case-control study (n=134) was carried out to analyse possible associations b...

  17. Construction, commissioning and initial operation of 2400W refrigerator and cold test stand for CDM testing

    International Nuclear Information System (INIS)

    Dubbs, J.D.; Kreinbrink, K.

    1994-01-01

    Air Products and CVI collaborated to design, construct and commission a refrigerator, test stands and integrated control system for the General Dynamics Collider Dipole Magnet Cold Test Facility (CTF) in Hammond, LA. The original project schedule required the cold test facility to be operational within 17 months of the notice to proceed. Midway through the project, changes in General Dynamics magnet testing requirements necessitated doubling the plant capacity, but the on stream date for the initial capacity increment could not be relaxed. The Air Products/CVI team had to adapt the project execution strategy to mitigate the schedule impact of the expansion in a cost effective manner without impacting system functionality, quality or safety. An equally challenging aspect of the job was that the (CTF) was being designed while several major systems that would interface with the CTF were being engineered. General Dynamics, Air Products and CVI had to work very closely to manage the interface issues. The teams efforts were very successful. The Hammond refrigerator/liquifier was started up on schedule. The first two test stands are currently being commissioned and will be on stream just six weeks later than the pre-expansion schedule target and all four test stands will be operational in time to support General Dynamics magnet testing requirements

  18. Pertussis outbreak in northwest Ireland, January - June 2010.

    LENUS (Irish Health Repository)

    Barret, A S

    2010-09-02

    We report a community pertussis outbreak that occurred in a small town located in the northwest of Ireland. Epidemiological investigations suggest that waning immunity and the absence of a booster dose during the second year of life could have contributed to the outbreak. The report also highlights the need to reinforce the surveillance of pertussis in Ireland and especially to improve the clinical and laboratory diagnosis of cases.

  19. Internet and free press are associated with reduced lags in global outbreak reporting.

    Science.gov (United States)

    McAlarnen, Lindsey; Smith, Katherine; Brownstein, John S; Jerde, Christopher

    2014-10-30

    Global outbreak detection and reporting have generally improved for a variety of infectious diseases and geographic regions in recent decades. Nevertheless, lags in outbreak reporting remain a threat to the global human health and economy. In the time between first occurrence of a novel disease incident and public notification of an outbreak, infected individuals have a greater possibility of traveling and spreading the pathogen to other nations. Shortening outbreak reporting lags has the potential to improve global health by preventing local outbreaks from escalating into global epidemics. Reporting lags between the first record and the first public report of an event were calculated for 318 outbreaks occurring 1996-2009. The influence of freedom of the press, Internet usage, per capita health expenditure, and cell phone subscriptions, on the timeliness of outbreak reporting was evaluated. Freer presses and increasing Internet usage correlate with reduced time between the first record of an outbreak and the public report. Increasing Internet usage reduced the expected reporting lag from more than one month in nations without Internet users to one day in those where 75 of 100 people use the Internet. Advances in technology and the emergence of more open and free governments are associated with to improved global infectious disease surveillance.

  20. Cold neutron production and application

    International Nuclear Information System (INIS)

    Inoue, Kazuhiko; Watanabe, Noboru.

    1976-01-01

    The first part gives general introduction to cold neutrons, namely the definition and the role as a probe in basic science and technology. The second part reviews various methods of cold neutron production. Some physical characteristics required for cold moderators are presented, and a list summarizes a number of cold moderators and their reactor physics constants. The definition of flux gain factor and the measured values for liquid light- and heavy-hydrogen are also given. The cold neutron spectra in methane and liquid hydrogen measured by LINAC time-of-flight method are presented to show the advantage of solid methane. The cold neutron sources using experimental reactors or linear accelerators are explained along with the examples of existing facilities. Two Japanese programs, the one is the use of a high flux reactor and the other is the use of a LINAC, are also presented. The third part of this report reviews the application areas of cold neutrons. (Aoki, K.)

  1. Effects of cold temperatures on the excitability of rat trigeminal ganglion neurons that are not for cold-sensing

    Science.gov (United States)

    Kanda, Hirosato; Gu, Jianguo G.

    2016-01-01

    Except a small population of primary afferent neurons for sensing cold to generate the sensations of innocuous and noxious cold, it is generally believed that cold temperatures suppress the excitability of other primary afferent neurons that are not for cold-sensing. These not-for-cold-sensing neurons include the majority of non-nociceptive and nociceptive afferent neurons. In the present study we have found that not-for-cold-sensing neurons of rat trigeminal ganglia (TG) change their excitability in several ways at cooling temperatures. In nearly 70% of not-for-cold-sensing TG neurons, the cooling temperature of 15°C increases their membrane excitability. We regard these neurons as cold-active neurons. For the remaining 30% of not-for-cold-sensing TG neurons, the cooling temperature of 15°C either has no effect (regarded as cold-ineffective neurons) or suppress (regarded as cold-suppressive neurons) their membrane excitability. For cold-active neurons, the cold temperature of 15°C increases their excitability as is evidenced by the increases in action potential (AP) firing numbers and/or reduction of AP rheobase when these neurons are depolarized electrically. The cold temperature of 15°C significantly inhibits M-currents and increases membrane input resistance of cold-active neurons. Retigabine, an M-current activator, abolishes the effect of cold temperatures on AP firing but not the effect of cold temperature on AP rheobase levels. The inhibition of M-currents and the increases of membrane input resistance are likely two mechanisms by which cooling temperatures increase the excitability of not-for-cold-sensing TG neurons. PMID:26709732

  2. How Will Climate Change Impact Cholera Outbreaks?

    Science.gov (United States)

    Nasr Azadani, F.; Jutla, A.; Rahimikolu, J.; Akanda, A. S.; Huq, A.; Colwell, R. R.

    2014-12-01

    Environmental parameters associated with cholera are well documented. However, cholera continues to be a global public health threat. Uncertainty in defining environmental processes affecting growth and multiplication of the cholera bacteria can be affected significantly by changing climate at different temporal and spatial scales, either through amplification of the hydroclimatic cycle or by enhanced variability of large scale geophysical processes. Endemic cholera in the Bengal Delta region of South Asia has a unique pattern of two seasonal peaks and there are associated with asymmetric and episodic variability in river discharge. The first cholera outbreak in spring is related with intrusion of bacteria laden coastal seawater during low river discharge. Cholera occurring during the fall season is hypothesized to be associated with high river discharge related to a cross-contamination of water resources and, therefore, a second wave of disease, a phenomenon characteristic primarily in the inland regions. Because of difficulties in establishing linkage between coarse resolutions of the Global Climate Model (GCM) output and localized disease outbreaks, the impact of climate change on diarrheal disease has not been explored. Here using the downscaling method of Support Vector Machines from HADCM3 and ECHAM models, we show how cholera outbreak patterns are changing in the Bengal Delta. Our preliminary results indicate statistically significant changes in both seasonality and magnitude in the occurrence of cholera over the next century. Endemic cholera is likely to transform into epidemic forms and new geographical areas will be at risk for cholera outbreaks.

  3. Cryptococcosis outbreak in psittacine birds in Brazil.

    Science.gov (United States)

    Raso, T F; Werther, K; Miranda, E T; Mendes-Giannini, M J S

    2004-08-01

    An outbreak of cryptococcosis occurred in a breeding aviary in São Paulo, Brazil. Seven psittacine birds (of species Charmosyna papou, Lorius lory, Trichoglossus goldiei, Psittacula krameri and Psittacus erithacus) died of disseminated cryptococcosis. Incoordination, progressive paralysis and difficulty in flying were seen in five birds, whereas superficial lesions coincident with respiratory alterations were seen in two birds. Encapsulated yeasts suggestive of Cryptococcus sp. were seen in faecal smears stained with India ink in two cases. Histological examination of the birds showed cryptococcal cells in various tissues, including the beak, choana, sinus, lungs, air sacs, heart, liver, spleen, kidneys, intestines and central nervous system. High titres of cryptococcal antigen were observed in the serum of an affected bird. In this case, titres increased during treatment and the bird eventually died. Yeasts were isolated from the nasal mass, faeces and liver of one bird. Cryptococcus neoformans var. gattii serovar B was identified based on biochemical, physiological and serological tests. These strains were resistant (minimum inhibitory concentration 64 microg/ml) to fluconazole. This is the first report of C. neoformans var. gattii occurring in psittacine birds in Brazil.

  4. The Nav1.9 channel is a key determinant of cold pain sensation and cold allodynia.

    Science.gov (United States)

    Lolignier, Stéphane; Bonnet, Caroline; Gaudioso, Christelle; Noël, Jacques; Ruel, Jérôme; Amsalem, Muriel; Ferrier, Jérémy; Rodat-Despoix, Lise; Bouvier, Valentine; Aissouni, Youssef; Prival, Laetitia; Chapuy, Eric; Padilla, Françoise; Eschalier, Alain; Delmas, Patrick; Busserolles, Jérôme

    2015-05-19

    Cold-triggered pain is essential to avoid prolonged exposure to harmfully low temperatures. However, the molecular basis of noxious cold sensing in mammals is still not completely understood. Here, we show that the voltage-gated Nav1.9 sodium channel is important for the perception of pain in response to noxious cold. Nav1.9 activity is upregulated in a subpopulation of damage-sensing sensory neurons responding to cooling, which allows the channel to amplify subthreshold depolarizations generated by the activation of cold transducers. Consequently, cold-triggered firing is impaired in Nav1.9(-/-) neurons, and Nav1.9 null mice and knockdown rats show increased cold pain thresholds. Disrupting Nav1.9 expression in rodents also alleviates cold pain hypersensitivity induced by the antineoplastic agent oxaliplatin. We conclude that Nav1.9 acts as a subthreshold amplifier in cold-sensitive nociceptive neurons and is required for the perception of cold pain under normal and pathological conditions. Copyright © 2015 The Authors. Published by Elsevier Inc. All rights reserved.

  5. Identification of resistance and virulence factors in an epidemic Enterobacter hormaechei outbreak strain

    NARCIS (Netherlands)

    Paauw, A.; Caspers, M.P.M.; Leverstein-van Hall, M.A.; Schuren, F.H.J.; Montijn, R.C.; Verhoef, J.; Fluit, A.C.

    2009-01-01

    Bacterial strains differ in their ability to cause hospital outbreaks. Using comparative genomic hybridization, Enterobacter cloacae complex isolates were studied to identify genetic markers specific for Enterobacter cloacae complex outbreak strains. No outbreak-specific genes were found that were

  6. Cold-Weather Sports

    Science.gov (United States)

    ... Videos for Educators Search English Español Cold-Weather Sports KidsHealth / For Teens / Cold-Weather Sports What's in this article? What to Do? Classes ... weather. What better time to be outdoors? Winter sports can help you burn calories, increase your cardiovascular ...

  7. Application of Response Surface Methodology (RSM for Optimization of Operating Parameters and Performance Evaluation of Cooling Tower Cold Water Temperature

    Directory of Open Access Journals (Sweden)

    Ramkumar RAMAKRISHNAN

    2012-01-01

    Full Text Available The performance of a cooling tower was analyzed with various operating parameters tofind the minimum cold water temperature. In this study, optimization of operating parameters wasinvestigated. An experimental design was carried out based on central composite design (CCD withresponse surface methodology (RSM. This paper presents optimum operating parameters and theminimum cold water temperature using the RSM method. The RSM was used to evaluate the effectsof operating variables and their interaction towards the attainment of their optimum conditions.Based on the analysis, air flow, hot water temperature and packing height were high significanteffect on cold water temperature. The optimum operating parameters were predicted using the RSMmethod and confirmed through experiment.

  8. A comprehensive database of the geographic spread of past human Ebola outbreaks

    Science.gov (United States)

    Mylne, Adrian; Brady, Oliver J.; Huang, Zhi; Pigott, David M.; Golding, Nick; Kraemer, Moritz U.G.; Hay, Simon I.

    2014-01-01

    Ebola is a zoonotic filovirus that has the potential to cause outbreaks of variable magnitude in human populations. This database collates our existing knowledge of all known human outbreaks of Ebola for the first time by extracting details of their suspected zoonotic origin and subsequent human-to-human spread from a range of published and non-published sources. In total, 22 unique Ebola outbreaks were identified, composed of 117 unique geographic transmission clusters. Details of the index case and geographic spread of secondary and imported cases were recorded as well as summaries of patient numbers and case fatality rates. A brief text summary describing suspected routes and means of spread for each outbreak was also included. While we cannot yet include the ongoing Guinea and DRC outbreaks until they are over, these data and compiled maps can be used to gain an improved understanding of the initial spread of past Ebola outbreaks and help evaluate surveillance and control guidelines for limiting the spread of future epidemics. PMID:25984346

  9. 19th-century and early 20th-century jaundice outbreaks, the USA.

    Science.gov (United States)

    Teo, C G

    2018-01-01

    Historical enquiry into diseases with morbidity or mortality predilections for particular demographic groups can permit clarification of their emergence, endemicity, and epidemicity. During community-wide outbreaks of hepatitis A in the pre-vaccine era, clinical attack rates were higher among juveniles rather than adults. In community-wide hepatitis E outbreaks, past and present, mortality rates have been most pronounced among pregnant women. Examination for these characteristic predilections in reports of jaundice outbreaks in the USA traces the emergence of hepatitis A and also of hepatitis E to the closing three decades of the 19th century. Thereafter, outbreaks of hepatitis A burgeoned, whereas those of hepatitis E abated. There were, in addition, community-wide outbreaks that bore features of neither hepatitis A nor E; they occurred before the 1870s. The American Civil War antedated that period. If hepatitis A had yet to establish endemicity, then it would not underlie the jaundice epidemic that was widespread during the war. Such an assessment may be revised, however, with the discovery of more extant outbreak reports.

  10. Population control methods in stochastic extinction and outbreak scenarios.

    Directory of Open Access Journals (Sweden)

    Juan Segura

    Full Text Available Adaptive limiter control (ALC and adaptive threshold harvesting (ATH are two related control methods that have been shown to stabilize fluctuating populations. Large variations in population abundance can threaten the constancy and the persistence stability of ecological populations, which may impede the success and efficiency of managing natural resources. Here, we consider population models that include biological mechanisms characteristic for causing extinctions on the one hand and pest outbreaks on the other hand. These models include Allee effects and the impact of natural enemies (as is typical of forest defoliating insects. We study the impacts of noise and different levels of biological parameters in three extinction and two outbreak scenarios. Our results show that ALC and ATH have an effect on extinction and outbreak risks only for sufficiently large control intensities. Moreover, there is a clear disparity between the two control methods: in the extinction scenarios, ALC can be effective and ATH can be counterproductive, whereas in the outbreak scenarios the situation is reversed, with ATH being effective and ALC being potentially counterproductive.

  11. Population control methods in stochastic extinction and outbreak scenarios.

    Science.gov (United States)

    Segura, Juan; Hilker, Frank M; Franco, Daniel

    2017-01-01

    Adaptive limiter control (ALC) and adaptive threshold harvesting (ATH) are two related control methods that have been shown to stabilize fluctuating populations. Large variations in population abundance can threaten the constancy and the persistence stability of ecological populations, which may impede the success and efficiency of managing natural resources. Here, we consider population models that include biological mechanisms characteristic for causing extinctions on the one hand and pest outbreaks on the other hand. These models include Allee effects and the impact of natural enemies (as is typical of forest defoliating insects). We study the impacts of noise and different levels of biological parameters in three extinction and two outbreak scenarios. Our results show that ALC and ATH have an effect on extinction and outbreak risks only for sufficiently large control intensities. Moreover, there is a clear disparity between the two control methods: in the extinction scenarios, ALC can be effective and ATH can be counterproductive, whereas in the outbreak scenarios the situation is reversed, with ATH being effective and ALC being potentially counterproductive.

  12. Response to a large rotavirus outbreak on South Tarawa, Kiribati, 2013

    Directory of Open Access Journals (Sweden)

    Teanibuaka Tabunga

    2014-05-01

    Full Text Available Introduction: In July 2013, during annual independence celebrations in Kiribati, staff at Tungaru Central Hospital on South Tarawa reported an increase in children presenting with severe diarrhoea. This report describes the outbreak investigation, findings and response. Method: After notification of the outbreak, all health facilities on South Tarawa began reporting cases of acute diarrhoea and/or vomiting through the early warning syndromic surveillance system on a daily basis. Community awareness was raised and the public was encouraged to present to a health facility if ill with acute gastroenteritis. Specimens were collected and sent for laboratory testing. Results: Between 10 and 24 July 2013, 1118 cases of gastroenteritis were reported; 103 were hospitalized and six died. The median age of cases was one year (range: 0–68 years; 93.4% were aged less than five years. Rotavirus was identified in 81% of specimens tested. The outbreak response included enhanced surveillance, community education, clinical training and changes to in-hospital patient management for infection control. Discussion: This outbreak was the largest diarrhoea outbreak in Kiribati in five years. Factors that may have contributed to the magnitude and severity of the outbreak included high household density, inadequate sanitation infrastructure and a mass gathering – all increasing the chance of transmission – as well as limited clinical response capacity. The current outbreak highlights the importance of clinical management to minimize severe dehydration and death. Rotavirus vaccination should be considered as an adjunct to other comprehensive enteric disease control measures as recommended by the World Health Organization.

  13. Major outbreaks of the Douglas-fir tussock moth in Oregon and California.

    Science.gov (United States)

    Boyd E. Wickman; Richard R. Mason; C.G. Thompson

    1973-01-01

    Case histories of five tussock moth outbreaks that occurred in California and Oregon between 1935 and 1965 are discussed. Information is given on the size and duration of the outbreaks, the presence of natural control agents and the damage caused. Most of the outbreaks were eventually treated with DDT. However, enough information was available from untreated portions...

  14. Habitat evaluation for outbreak of Yangtze voles (Microtus fortis) and management implications.

    Science.gov (United States)

    Xu, Zhenggang; Zhao, Yunlin; Li, Bo; Zhang, Meiwen; Shen, Guo; Wang, Yong

    2015-05-01

    Rodent pests severely damage agricultural crops. Outbreak risk models of rodent pests often do not include sufficient information regarding geographic variation. Habitat plays an important role in rodent-pest outbreak risk, and more information about the relationship between habitat and crop protection is urgently needed. The goal of the present study was to provide an outbreak risk map for the Dongting Lake region and to understand the relationship between rodent-pest outbreak variation and habitat distribution. The main rodent pests in the Dongting Lake region are Yangtze voles (Microtus fortis). These pests cause massive damage in outbreak years, most notably in 2007. Habitat evaluation and ecological details were obtained by analyzing the correlation between habitat suitability and outbreak risk, as indicated by population density and historical events. For the source-sink population, 96.18% of Yangtze vole disaster regions were covered by a 10-km buffer zone of suitable habitat in 2007. Historical outbreak frequency and peak population density were significantly correlated with the proportion of land covered by suitable habitat (r = 0.68, P = 0.04 and r = 0.76, P = 0.03, respectively). The Yangtze vole population tends to migrate approximately 10 km in outbreak years. Here, we propose a practical method for habitat evaluation that can be used to create integrated pest management plans for rodent pests when combined with basic information on the biology, ecology and behavior of the target species. © 2014 International Society of Zoological Sciences, Institute of Zoology/Chinese Academy of Sciences and Wiley Publishing Asia Pty Ltd.

  15. Rapid control of a chancroid outbreak: implications for Canada.

    Science.gov (United States)

    Jessamine, P G; Brunham, R C

    1990-01-01

    From June to November 1987 an outbreak of chancroid occurred in Winnipeg, the first in more than 10 years; 14 people (9 men, 5 women) were involved. Nine of the cases were confirmed through culture. A control strategy was implemented in November 1987 that included presumptive treatment of genital ulcer disease with single-dose antimicrobial therapy, intensive tracing of contacts and treatment of asymptomatic sexual contacts. The origin of the outbreak was not determined, and an epidemiologic link between all the patients could not be demonstrated. The isolates were found to contain the same plasmid; this suggested that a single clone of Haemophilus ducreyi was responsible for the outbreak. Images Fig. 2 PMID:2337844

  16. Cold fusion

    International Nuclear Information System (INIS)

    Koster, J.

    1989-01-01

    In this contribution the author the phenomenom of so-called cold fusion, inspired by the memorable lecture of Moshe Gai on his own search for this effect. Thus much of what follows was presented by Dr. Gai; the rest is from independent reading. What is referred to as cold fusion is of course the observation of possible products of deuteron-deuteron (d-d) fusion within deuterium-loaded (dentended) electrodes. The debate over the two vanguard cold fusion experiments has raged under far more public attention than usually accorded new scientific phenomena. The clamor commenced with the press conference of M. Fleishmann and S. Pons on March 23, 1989 and the nearly simultaneous wide circulation of a preprint of S. Jones and collaborators. The majority of work attempting to confirm these observations has at the time of this writing yet to appear in published form, but contributions to conferences and electronic mail over computer networks were certainly filled with preliminary results. To keep what follows to a reasonable length the author limit this discussion to the searches for neutron (suggested by ref. 2) or for excessive heat production (suggested by ref. 1), following a synopsis of the hypotheses of cold fusion

  17. Interactive short-term effects of equivalent temperature and air pollution on human mortality in Berlin and Lisbon

    International Nuclear Information System (INIS)

    Burkart, Katrin; Canário, Paulo; Breitner, Susanne; Schneider, Alexandra; Scherber, Katharina; Andrade, Henrique; Alcoforado, Maria João; Endlicher, Wilfried

    2013-01-01

    There is substantial evidence that both temperature and air pollution are predictors of mortality. Thus far, few studies have focused on the potential interactive effects between the thermal environment and different measures of air pollution. Such interactions, however, are biologically plausible, as (extreme) temperature or increased air pollution might make individuals more susceptible to the effects of each respective predictor. This study investigated the interactive effects between equivalent temperature and air pollution (ozone and particulate matter) in Berlin (Germany) and Lisbon (Portugal) using different types of Poisson regression models. The findings suggest that interactive effects exist between air pollutants and equivalent temperature. Bivariate response surface models and generalised additive models (GAMs) including interaction terms showed an increased risk of mortality during periods of elevated equivalent temperatures and air pollution. Cold effects were mostly unaffected by air pollution. The study underscores the importance of air pollution control in mitigating heat effects. -- Highlights: • Interactive effects between air pollution and equivalent temperature result in augmented excess mortality. • High levels of ozone and particulate matter increase adverse heat effects on human mortality. • Cold effects are mostly unaffected by air pollution. • Findings underscore the importance of air pollution control in mitigating heat-related mortality. -- Interactive effects between air pollution and elevated (equivalent) temperatures underscore the importance of air pollution control in mitigating the adverse effects of heat

  18. outbreak of hepatitis 'E' in risalpur garrison

    International Nuclear Information System (INIS)

    Sharif, T.B.; Tariq, W.U.Z.

    2007-01-01

    Hepatitis E virus is an RNA virus. It results in epidemics/outbreaks in geographical areas lacking clean water and sanitation. It is excreted in stools and is enterically transmitted (faeco-oral route). The clinical picture resembles other acute hepatitis and diagnosis is clinched by detecting anti-HEV IgM in infected individuals. It is a self-limiting disease and does not progress to chronicity. There is no vaccine available so far, to confer immunity against HEV infection. HEV is endemic in many parts of the world and has resulted in many epidemics / outbreaks worldwide. It is also endemic in Pakistan and epidemics / outbreaks have generally been under reported. To establish the cause of outbreak Blood samples of the patients (n=195), admitted in isolation ward were collected aseptically for routine baseline investigations and hepatitis screening. Separate blood samples were sent to Armed Forces Institute of pathology (AFIP), Rawalpindi for detection of antibodies to hepatitis E virus (Anti HEV IgM). Water samples collected during the outbreak were tested by multiple tube technique. MPN (Most Probable Number) method was used to determine faecal coliform bacteria per 100 ml of water sample. All the patients (n=195) on admission had raised ALT (Alanine Aminotransferase) levels along with hyperbilirubinemia, 37% had raised TLC with polymorphonuclear response. None had HBsAg (Hepatitis B surface antign) or anti-HCV (antibodies to hepatitis C virus), 23% had prolonged PT (Prothrombin Time). Samples despatched to AFIP Rawalpindi confirmed the presence of anti-HEV IgM. Follow up analysis revealed many fold increase in ALT levels. Average stay in the Hospital was 23.6 days per patient. All the water samples were declared unfit for drinking due to high coliform count. At present, no vaccine is available to protect against HEV infection. Mainstay for prevention and occurrence is to formulate cost-effective strategies for improvement of self/environmental hygiene and

  19. Model-based prediction of nephropathia epidemica outbreaks based on climatological and vegetation data and bank vole population dynamics.

    Science.gov (United States)

    Haredasht, S Amirpour; Taylor, C J; Maes, P; Verstraeten, W W; Clement, J; Barrios, M; Lagrou, K; Van Ranst, M; Coppin, P; Berckmans, D; Aerts, J-M

    2013-11-01

    Wildlife-originated zoonotic diseases in general are a major contributor to emerging infectious diseases. Hantaviruses more specifically cause thousands of human disease cases annually worldwide, while understanding and predicting human hantavirus epidemics pose numerous unsolved challenges. Nephropathia epidemica (NE) is a human infection caused by Puumala virus, which is naturally carried and shed by bank voles (Myodes glareolus). The objective of this study was to develop a method that allows model-based predicting 3 months ahead of the occurrence of NE epidemics. Two data sets were utilized to develop and test the models. These data sets were concerned with NE cases in Finland and Belgium. In this study, we selected the most relevant inputs from all the available data for use in a dynamic linear regression (DLR) model. The number of NE cases in Finland were modelled using data from 1996 to 2008. The NE cases were predicted based on the time series data of average monthly air temperature (°C) and bank voles' trapping index using a DLR model. The bank voles' trapping index data were interpolated using a related dynamic harmonic regression model (DHR). Here, the DLR and DHR models used time-varying parameters. Both the DHR and DLR models were based on a unified state-space estimation framework. For the Belgium case, no time series of the bank voles' population dynamics were available. Several studies, however, have suggested that the population of bank voles is related to the variation in seed production of beech and oak trees in Northern Europe. Therefore, the NE occurrence pattern in Belgium was predicted based on a DLR model by using remotely sensed phenology parameters of broad-leaved forests, together with the oak and beech seed categories and average monthly air temperature (°C) using data from 2001 to 2009. Our results suggest that even without any knowledge about hantavirus dynamics in the host population, the time variation in NE outbreaks in Finland

  20. Large outbreaks of Salmonella Typhimurium infection in Denmark in 2008

    DEFF Research Database (Denmark)

    Ethelberg, S.; Wingstrand, Anne; Jensen, T.

    2008-01-01

    An outbreak of Salmonella Typhimurium phage type U292 has been ongoing in Denmark since 1 April, with 1,054 cases registered until 23 October 2008. Extensive investigations including hypothesis-generating interviews, matched case-control studies, cohort studies in embedded outbreaks, shopping list...

  1. Measles Cases during Ebola Outbreak, West Africa, 2013-2106.

    Science.gov (United States)

    Colavita, Francesca; Biava, Mirella; Castilletti, Concetta; Quartu, Serena; Vairo, Francesco; Caglioti, Claudia; Agrati, Chiara; Lalle, Eleonora; Bordi, Licia; Lanini, Simone; Guanti, Michela Delli; Miccio, Rossella; Ippolito, Giuseppe; Capobianchi, Maria R; Di Caro, Antonino

    2017-06-01

    The recent Ebola outbreak in West Africa caused breakdowns in public health systems, which might have caused outbreaks of vaccine-preventable diseases. We tested 80 patients admitted to an Ebola treatment center in Freetown, Sierra Leone, for measles. These patients were negative for Ebola virus. Measles virus IgM was detected in 13 (16%) of the patients.

  2. A review of outbreaks of waterborne disease associated with ships: evidence for risk management.

    Science.gov (United States)

    Rooney, Roisin M; Bartram, Jamie K; Cramer, Elaine H; Mantha, Stacey; Nichols, Gordon; Suraj, Rohini; Todd, Ewen C D

    2004-01-01

    The organization of water supply to and on ships differs considerably from that of water supply on land. Risks of contamination can arise from source water at the port or during loading, storage, or distribution on the ship. The purpose of this article is to review documented outbreaks of waterborne diseases associated with passenger, cargo, fishing, and naval ships to identify contributing factors so that similar outbreaks can be prevented in the future. The authors reviewed 21 reported outbreaks of waterborne diseases associated with ships. For each outbreak, data on pathogens/toxins, type of ship, factors contributing to outbreaks, mortality and morbidity, and remedial action are presented. The findings of this review show that the majority of reported outbreaks were associated with passenger ships and that more than 6,400 people were affected. Waterborne outbreaks due to Enterotoxigenic Escherichia coli, noroviruses, Salmonella spp, Shigella sp, Cryptosporidium sp, and Giardia lamblia occurred on ships. Enterotoxigenic E. coli was the pathogen most frequently associated with outbreaks. One outbreak of chemical water poisoning also occurred on a ship. Risk factors included contaminated port water, inadequate treatment, improper loading techniques, poor design and maintenance of storage tanks, ingress of contamination during repair and maintenance, cross-connections, back siphonage, and insufficient residual disinfectant. Waterborne disease outbreaks on ships can be prevented. The factors contributing to outbreaks emphasize the need for hygienic handling of water along the supply chain from source to consumption. A comprehensive approach to water safety on ships is essential. This may be achieved by the adoption of Water Safety Plans that cover design, construction, operation, and routine inspection and maintenance.

  3. Perspectives on West Africa Ebola Virus Disease Outbreak, 2013-2016.

    Science.gov (United States)

    Spengler, Jessica R; Ervin, Elizabeth D; Towner, Jonathan S; Rollin, Pierre E; Nichol, Stuart T

    2016-06-01

    The variety of factors that contributed to the initial undetected spread of Ebola virus disease in West Africa during 2013-2016 and the difficulty controlling the outbreak once the etiology was identified highlight priorities for disease prevention, detection, and response. These factors include occurrence in a region recovering from civil instability and lacking experience with Ebola response; inadequate surveillance, recognition of suspected cases, and Ebola diagnosis; mobile populations and extensive urban transmission; and the community's insufficient general understanding about the disease. The magnitude of the outbreak was not attributable to a substantial change of the virus. Continued efforts during the outbreak and in preparation for future outbreak response should involve identifying the reservoir, improving in-country detection and response capacity, conducting survivor studies and supporting survivors, engaging in culturally appropriate public education and risk communication, building productive interagency relationships, and continuing support for basic research.

  4. Design of Green Cold Chain Networks for Imported Fresh Agri-Products in Belt and Road Development

    Directory of Open Access Journals (Sweden)

    Yan Fang

    2018-05-01

    Full Text Available The development of Belt and Road has seen a boom of imported fresh agri-products in China. This stimulates the growth of refrigerated transport, which accounts for much more carbon emissions than traditional transport. Designing a sustainable cold chain network is of vital importance from both financial and environmental perspectives. In this research, a multi-objective linear programming model is proposed for green cold chain design for multiple imported fresh agri-products in China to balance between the two competing goals—the total cost and carbon emissions. The effect of the outdoor air temperature on the carbon emissions of transportation and maintaining distribution centers is considered. By applying the ε-constraint method, the multi-objective model is solved. Numerical examples derived from the scenario of imported fresh-agri products in China are conducted to shed light on green cold chain design under Belt and Road development.

  5. Positive impact of infection prevention on the management of nosocomial outbreaks at an academic hospital.

    Science.gov (United States)

    Dik, Jan-Willem H; Sinha, Bhanu; Lokate, Mariëtte; Lo-Ten-Foe, Jerome R; Dinkelacker, Ariane G; Postma, Maarten J; Friedrich, Alexander W

    2016-10-01

    Infection prevention (IP) measures are vital to prevent (nosocomial) outbreaks. Financial evaluations of these are scarce. An incremental cost analysis for an academic IP unit was performed. On a yearly basis, we evaluated: IP measures; costs thereof; numbers of patients at risk for causing nosocomial outbreaks; predicted outbreak patients; and actual outbreak patients. IP costs rose on average yearly with €150,000; however, more IP actions were undertaken. Numbers of patients colonized with high-risk microorganisms increased. The trend of actual outbreak patients remained stable. Predicted prevented outbreak patients saved costs, leading to a positive return on investment of 1.94. This study shows that investments in IP can prevent outbreak cases, thereby saving enough money to earn back these investments.

  6. Discovering network behind infectious disease outbreak

    Science.gov (United States)

    Maeno, Yoshiharu

    2010-11-01

    Stochasticity and spatial heterogeneity are of great interest recently in studying the spread of an infectious disease. The presented method solves an inverse problem to discover the effectively decisive topology of a heterogeneous network and reveal the transmission parameters which govern the stochastic spreads over the network from a dataset on an infectious disease outbreak in the early growth phase. Populations in a combination of epidemiological compartment models and a meta-population network model are described by stochastic differential equations. Probability density functions are derived from the equations and used for the maximal likelihood estimation of the topology and parameters. The method is tested with computationally synthesized datasets and the WHO dataset on the SARS outbreak.

  7. Multiscale model for pedestrian and infection dynamics during air travel

    Science.gov (United States)

    Namilae, Sirish; Derjany, Pierrot; Mubayi, Anuj; Scotch, Mathew; Srinivasan, Ashok

    2017-05-01

    In this paper we develop a multiscale model combining social-force-based pedestrian movement with a population level stochastic infection transmission dynamics framework. The model is then applied to study the infection transmission within airplanes and the transmission of the Ebola virus through casual contacts. Drastic limitations on air-travel during epidemics, such as during the 2014 Ebola outbreak in West Africa, carry considerable economic and human costs. We use the computational model to evaluate the effects of passenger movement within airplanes and air-travel policies on the geospatial spread of infectious diseases. We find that boarding policy by an airline is more critical for infection propagation compared to deplaning policy. Enplaning in two sections resulted in fewer infections than the currently followed strategy with multiple zones. In addition, we found that small commercial airplanes are better than larger ones at reducing the number of new infections in a flight. Aggregated results indicate that passenger movement strategies and airplane size predicted through these network models can have significant impact on an event like the 2014 Ebola epidemic. The methodology developed here is generic and can be readily modified to incorporate the impact from the outbreak of other directly transmitted infectious diseases.

  8. The Influence of the Antarctic Oscillation (AAO on Cold Waves and Occurrence of Frosts in the State of Santa Catarina, Brazil

    Directory of Open Access Journals (Sweden)

    Maikon Passos A. Alves

    2017-03-01

    Full Text Available This paper examines the relationship between the Antarctic Oscillation (AAO, cold waves and occurrence of frosts in the state of Santa Catarina, Brazil, during the winter quarter. Research on this topic can assist different spheres of society, such as public health and agriculture, since cold waves can influence and/or aggravate health problems and frosts can inflict economic losses especially in the agricultural sector. For the purpose of this paper, cold wave is considered as the event in which the daily average surface air temperature was at least two standard deviations below the average value of the series on the day and for two consecutive days or more. The data on the average air temperature and frost occurrences are provided by the Company of Agricultural Research and Rural Extension of Santa Catarina/Center for Environmental Information and Hydrometeorology (EPAGRI/CIRAM. The AAO was subjected to statistical analysis using significance tests for the averages (Student’s t-test and variances (F-test with a significance level of α = 5%. The results show that cold waves are unevenly distributed in the agroecological zones of Santa Catarina. It is found that the AAO is associated with the occurrence of frosts (in the agroecological zones represented by the municipalities of Itajaí and São José in the state of Santa Catarina.

  9. Statistics of severe tornadoes and severe tornado outbreaks

    Directory of Open Access Journals (Sweden)

    B. D. Malamud

    2012-09-01

    Full Text Available The standard measures of the intensity of a tornado in the USA and many other countries are the Fujita and Enhanced Fujita scales. These scales are based on the damage that a tornado causes. Another measure of the strength of a tornado is its path length of touchdown, L. In this study we consider severe tornadoes, which we define as L≥10 km, in the continental USA (USA Storm Prediction Center Severe Weather Database. We find that for the period 1982–2011, for individual severe tornadoes (L≥10 km: (i There is a strong linear scaling between the number of severe tornadoes in a year and their total path length in that year. (ii The cumulative frequency path length data suggests that, not taking into account any changing trends over time, we would expect in a given year (on average one severe tornado with a path length L≥115 km and in a decade (on average one severe tornado with a path length L≥215 km. (iii The noncumulative frequency-length statistics of severe tornado touchdown path lengths, 20<L<200 km, is well approximated by an inverse power-law relationship with exponent near 3. We then take the total path length of severe tornadoes in a convective day (12:00–12:00 UTC, LD, as a measure of the strength of a 24-h USA tornado outbreak. We find that: (i For 1982–2011, the number of severe tornadoes in a USA convective day outbreak has a strong power-law relationship (exponent 0.80 on the convective day total path length, LD. (ii For 1952–2011, the cumulative frequency path length data for severe tornado outbreaks suggests that we would expect in a given year (on average one daily severe tornado outbreak with total path length LD≥480 km and in a decade (on average one daily severe tornado outbreak with a total path length LD≥1200 km. (iii For 1982–2011, the noncumulative frequency-length statistics of tornado

  10. Dynamics of epidemics outbreaks in heterogeneous populations

    Science.gov (United States)

    Brockmann, Dirk; Morales-Gallardo, Alejandro; Geisel, Theo

    2007-03-01

    The dynamics of epidemic outbreaks have been investigated in recent years within two alternative theoretical paradigms. The key parameter of mean field type of models such as the SIR model is the basic reproduction number R0, the average number of secondary infections caused by one infected individual. Recently, scale free network models have received much attention as they account for the high variability in the number of social contacts involved. These models predict an infinite basic reproduction number in some cases. We investigate the impact of heterogeneities of contact rates in a generic model for epidemic outbreaks. We present a system in which both the time periods of being infectious and the time periods between transmissions are Poissonian processes. The heterogeneities are introduced by means of strongly variable contact rates. In contrast to scale free network models we observe a finite basic reproduction number and, counterintuitively a smaller overall epidemic outbreak as compared to the homogeneous system. Our study thus reveals that heterogeneities in contact rates do not necessarily facilitate the spread to infectious disease but may well attenuate it.

  11. Human whole body cold adaptation.

    OpenAIRE

    Daanen, Hein A.M.; Van Marken Lichtenbelt, Wouter D.

    2016-01-01

    ABSTRACT Reviews on whole body human cold adaptation generally do not distinguish between population studies and dedicated acclimation studies, leading to confusing results. Population studies show that indigenous black Africans have reduced shivering thermogenesis in the cold and poor cold induced vasodilation in fingers and toes compared to Caucasians and Inuit. About 40,000?y after humans left Africa, natives in cold terrestrial areas seems to have developed not only behavioral adaptations...

  12. Avalanche outbreaks emerging in cooperative contagions

    Science.gov (United States)

    Cai, Weiran; Chen, Li; Ghanbarnejad, Fakhteh; Grassberger, Peter

    2015-11-01

    The spreading of contagions can exhibit a percolation transition, which separates transitory prevalence from outbreaks that reach a finite fraction of the population. Such transitions are commonly believed to be continuous, but empirical studies have shown more violent spreading modes when the participating agents are not limited to one type. Striking examples include the co-epidemic of the Spanish flu and pneumonia that occurred in 1918 (refs , ), and, more recently, the concurrent prevalence of HIV/AIDS and a host of diseases. It remains unclear to what extent an outbreak in the presence of interacting pathogens differs from that due to an ordinary single-agent process. Here we study a mechanistic model for understanding contagion processes involving inter-agent cooperation. Our stochastic simulations reveal the possible emergence of a massive avalanche-like outbreak right at the threshold, which is manifested as a discontinuous phase transition. Such an abrupt change arises only if the underlying network topology supports a bottleneck for cascaded mutual infections. Surprisingly, all these discontinuous transitions are accompanied by non-trivial critical behaviours, presenting a rare case of hybrid transition. The findings may imply the origin of catastrophic occurrences in many realistic systems, from co-epidemics to financial contagions.

  13. Cryptosporidiosis outbreaks associated with recreational water use--five states, 2006.

    Science.gov (United States)

    2007-07-27

    Cryptosporidiosis is a gastrointestinal illness caused by parasitic protozoa of the genus Cryptosporidium and can produce watery diarrhea lasting 1-3 weeks; one or two cases per 100,000 population are reported annually in the United States. Fecal-oral transmission of Cryptosporidium oocysts occurs through ingestion of contaminated drinking or recreational water, consumption of contaminated food, and contact with infected persons or animals (e.g., cattle or sheep). Unlike bacterial pathogens, Cryptosporidium oocysts are resistant to chlorine disinfection and can survive for days in treated recreational water venues (e.g., public and residential swimming pools and community and commercial water parks) despite adherence to recommended residual chlorine levels (1-3 ppm). For 2006, a total of 18 cryptosporidiosis outbreaks have been reported (as of July 24, 2007) to CDC's U.S. Waterborne Disease and Outbreak Surveillance System, compared with five outbreaks reported for 2003 and seven for 2004; data for 2005 and 2006 are not yet final. This report describes five laboratory-confirmed cryptosporidiosis outbreaks in 2006 that involved public recreational water use. The popularity of recreational water venues, the number and geographic distribution of recent cryptosporidiosis outbreaks, and the resistance of Cryptosporidium to chlorination suggest that treatment strategies for recreational water facilities need to be improved.

  14. Natural Disasters and Cholera Outbreaks: Current Understanding and Future Outlook.

    Science.gov (United States)

    Jutla, Antarpreet; Khan, Rakibul; Colwell, Rita

    2017-03-01

    Diarrheal diseases remain a serious global public health threat, especially for those populations lacking access to safe water and sanitation infrastructure. Although association of several diarrheal diseases, e.g., cholera, shigellosis, etc., with climatic processes has been documented, the global human population remains at heightened risk of outbreak of diseases after natural disasters, such as earthquakes, floods, or droughts. In this review, cholera was selected as a signature diarrheal disease and the role of natural disasters in triggering and transmitting cholera was analyzed. Key observations include identification of an inherent feedback loop that includes societal structure, prevailing climatic processes, and spatio-temporal seasonal variability of natural disasters. Data obtained from satellite-based remote sensing are concluded to have application, although limited, in predicting risks of a cholera outbreak(s). We argue that with the advent of new high spectral and spatial resolution data, earth observation systems should be seamlessly integrated in a decision support mechanism to be mobilize resources when a region suffers a natural disaster. A framework is proposed that can be used to assess the impact of natural disasters with response to outbreak of cholera, providing assessment of short- and long-term influence of climatic processes on disease outbreaks.

  15. Human whole body cold adaptation.

    NARCIS (Netherlands)

    Daanen, Hein A.M.; Van Marken Lichtenbelt, Wouter D.

    2016-01-01

    Reviews on whole body human cold adaptation generally do not distinguish between population studies and dedicated acclimation studies, leading to confusing results. Population studies show that indigenous black Africans have reduced shivering thermogenesis in the cold and poor cold induced

  16. Measles (Rubeola) Cases and Outbreaks

    Science.gov (United States)

    ... Address What’s this? Submit What's this? Submit Button Measles Cases and Outbreaks Language: English (US) Español (Spanish) ... Español: Casos y brotes de sarampión Number of measles cases by year since 2010 Measles cases per ...

  17. Multiple origins of outbreak populations of a native insect pest in an agro-ecosystem.

    Science.gov (United States)

    Kobayashi, T; Sakurai, T; Sakakibara, M; Watanabe, T

    2011-06-01

    Native insects can become epidemic pests in agro-ecosystems. A population genetics approach was applied to analyze the emergence and spread of outbreak populations of native insect species. Outbreaks of the mirid bug, Stenotus rubrovittatus, have rapidly expanded over Japan within the last two decades. To characterize the outbreak dynamics of this species, the genetic structure of local populations was assessed using polymorphisms of the mtDNA COI gene and six microsatellite loci. Results of the population genetic analysis suggested that S. rubrovittatus populations throughout Japan were genetically isolated by geographic distance and separated into three genetic clusters occupying spatially segregated regions. Phylogeographic analysis indicated that the genetic structure of S. rubrovittatus reflected post-glacial colonization. Early outbreaks of S. rubrovittatus in the 1980s occurred independently of genetically isolated populations. The genetic structure of the populations did not fit the pattern of an outbreak expansion, and therefore the data did not support the hypothesis that extensive outbreaks were caused by the dispersal of specific pestiferous populations. Rather, the historical genetic structure prior to the outbreaks was maintained throughout the increase in abundance of the mirid bug. Our study indicated that changes in the agro-environment induced multiple outbreaks of native pest populations. This implies that, given suitable environmental conditions, local populations may have the potential to outbreak even without invasion of populations from other environmentally degraded areas.

  18. Epidemiological investigation and analysis of bronchial asthma in combat troops garrisoned in the cold areas of northeast China

    Directory of Open Access Journals (Sweden)

    Liang SHI

    2016-04-01

    Full Text Available Objective  To investigate the incidence and related risk factors of occurrence of bronchial asthma in troops garrisoned in the cold areas of northeast China, and explore the corresponding prevention strategy. Methods  A portion of the recruits enlisted in 2012 to Shenyang Command were enrolled as the subjects of the study with three questionnaires. The first questionnaire was carried out during training just after recruit. The second survey was carried out after winter training in selected recruits entering the army for two years, and the last questionnaire was carried out to select recruits just before their discharge from army. The final diagnosis of bronchial asthma in the suspected cases was established by pulmonary function test. Results  In the first period of the survey, the prevalence of asthma was found to be 3.55‰in the newly enlisted recruits; in the second survey 1067 cases were found to be suspicious to have asthma; in the last survey, 26 subjects were finally diagnosed to have asthma, the incidence was 1.73‰. The most common symptoms of the illness at first attack were cough (88.5% and wheeziness (56.3%, and the main inducing factors were respiratory tract infection (76.9% and exposure to cold air (65.4%, and it frequently appeared at early morning (30.8% and forenoon (23.1%. Asthmatic attack presented obvious seasonal predisposition, and it occurred in 19 of 26 patients (73.1% during winter, and 10 (38.5% during spring. The attacks of asthma could be increased by fatigue, allergy, exposure to cold air, chronic bronchitis, smoking, inhalation of gunpowder exhaust, or dysthymia. Conclusion  Fatigue may be the most frequent factor in inducing asthma, and allergy, exposure to cold air, chronic bronchitis, smoking, inhalation of gunpowder exhaust and dysthymia are the risk factors of asthmatic attack. DOI: 10.11855/j.issn.0577-7402.2016.04.13

  19. Cold temperature induces mucin hypersecretion from normal human bronchial epithelial cells in vitro through a transient receptor potential melastatin 8 (TRPM8)-mediated mechanism.

    Science.gov (United States)

    Li, MinChao; Li, Qi; Yang, Gang; Kolosov, Victor P; Perelman, Juliy M; Zhou, Xiang Dong

    2011-09-01

    Cold air stimulus is a major environmental factor that exacerbates chronic inflammatory airway diseases, such as chronic obstructive pulmonary disease (COPD) and asthma. At the molecular level, cold is detected by transient receptor potential melastatin 8 (TRPM8). To date, TRPM8 expression has not been characterized in the airway epithelium of patients with COPD. The role of TRPM8 channels in a series of airway responses induced by cold stimuli and the molecular and biochemical pathways of TRPM8 in regulating cold-induced responses are largely unknown. We sought to explore the role of TRPM8 in cold air-provoked mucus hypersecretion and the potential signaling pathway involved in this process. The expression of TRPM8 in the bronchial epithelium was examined by means of immunohistochemistry, RT-PCR, and Western blotting. TRPM8 receptor function and hydrolysis of phosphatidylinositol 4,5-bisphosphate (PIP2) were characterized by means of Ca(2+) imaging and spatiotemporal dynamics of phospholipase C (PLC) δ1-pleckstrin homology-green fluorescent protein, respectively. The expression of MUC5AC mRNA and MUC5AC mucin protein was measured by using real-time PCR and ELISA, respectively. Four serine residues in the myristoylated alanine-rich C kinase substrate (MARCKS)-phosphorylation site domain were mutated to identify the function of MARCKS in TRPM8-mediated airway mucus hypersecretion. TRPM8 protein and mRNA expression were significantly increased in patients with COPD compared with expression seen in healthy subjects. Cold produced robust increases in intracellular Ca(2+) levels and promoted translocation of PLCδ1-pleckstrin homology-green fluorescent protein. Cold increased expression of MUC5AC mRNA and intracellular and secreted MUC5AC protein in a nonsustained way. Phosphorylation site domain-mutant MARCKS cDNA hindered MUC5AC secretion induced by cold. These results indicate that the TRPM8 receptor is involved in cold-induced mucus hypersecretion through the Ca(2

  20. Asian Dust Storm Outbreaks: A Satellite-Surface Perspective

    Science.gov (United States)

    Tsay, Si-Chee

    2006-01-01

    Airborne dusts from northern China contribute a significant part of the air quality problem and, to some extent, regional climatic impact in Asia during springtime. Asian dust typically originates in desert areas far from polluted urban regions. During the transport, dust layers can interact with anthropogenic sulfate and soot aerosols from heavily polluted urban areas. Added to the complex effects of clouds and natural marine aerosols, dust particles reaching the marine environment can have drastically different properties than those from the source. Thus, understanding the unique temporal and spatial variations of Asian dust is of special importance in regional-to-global climate issues (e.g., radiative forcing, hydrological cycle, and primary biological productivity in the mid-Pacific Ocean, etc.), as well as societal concerns (e.g., adverse health effects to humans). The Asian dust and air pollution aerosols can be detected by its colored appearance on current Earth observing satellites (e.g., MODIS, SeaWiFS, TOMS, etc.) and its evolution monitored by satellites and surface network (e.g. AERONET, SKY NET, MPLNET, etc.). Recently, many field campaigns (e.g., ACE-Asia-2001, TRACEP-2001, ADE-2002 & -2003, APEX-2001 & -2003, etc.) were designed and executed to study the compelling variability in spatial and temporal scale of both pollution-derived and naturally occurring aerosols, which often exist in high concentrations over eastern Asia and along the rim of the western Pacific. I will present an overview of the outbreak of Asian dust storms from space and surface observations and to address the climatic effects and societal impacts.