WorldWideScience

Sample records for cold air application

  1. Application of Cascade Refrigeration System with Mixing Refrigerant in Cold Air Cutting

    Yang, Y.; Tong, M. W.; Yang, G.; Wang, X. P.

    In the mechanical cutting process, the replacement of traditional cutting solution with cold air can avoid the pollution of environment. In order to high efficient the refrigerating device and flexible adjust the temperature of cold air, it is necessary to use cascade refrigeration system to supply cool quantity for the compressed air. The introduction of a two-component non-azeotropic mixing refrigerant into the cryogenic part of the cascade system, can effectively solve the problems of the system working at too high pressure and the volume expanding of refrigerant in case of the cascade refrigeration sets closed down. However, the filling ratio of mixing refrigerants impact on the relationships among the closing down pressure, refrigerating output and refrigerating efficiency. On the basis of computing and experiment, the optimal mixing ratio of refrigerant R22/R13 and a low temperature of -60° were obtained in this study. A cold air injecting device possessing high efficiency in energy saving has also been designed and manufactured. The cold air, generated from this cascade system and employed in a cutting process, takes good comprehensive effects on machining and cutting.

  2. Application and verification of cold air velocity technique for solving tube ash erosion problem in PC boilers

    Yoo, Kisoo; Jeong, Kwon Seok [Korea Southern Power Corporation, Gimhae (Korea, Republic of)

    2012-06-15

    Fly ash erosion is a leading cause of boiler tube failure in PC boilers. Therefore, shields or baffle plates are installed in specific areas to mitigate fly ash erosion and prevent boiler tube failure. However, the tube failure problems caused by fly ash erosion cannot be eliminated with this solution alone, because each PC boiler has a different flue gas flow pattern and erosion can become severe in unexpected zones. This problem is caused by an asymmetric internal flow velocity and local growth of the flue gas velocity. For these reasons, clearly defining the flow pattern in PC boilers is important for solving the problem of tube failure caused by fly ash erosion. For this purpose, the cold air velocity technique (CAVT) can be applied to the fly ash erosion problem. In this study, CAVT was carried out on the Hadong 2 PC boiler and the feasibility of application of CAVT to conventional PC boilers was validated.

  3. Application and verification of cold air velocity technique for solving tube ash erosion problem in PC boilers

    Yoo, Kisoo; Jeong, Kwon Seok

    2012-01-01

    Fly ash erosion is a leading cause of boiler tube failure in PC boilers. Therefore, shields or baffle plates are installed in specific areas to mitigate fly ash erosion and prevent boiler tube failure. However, the tube failure problems caused by fly ash erosion cannot be eliminated with this solution alone, because each PC boiler has a different flue gas flow pattern and erosion can become severe in unexpected zones. This problem is caused by an asymmetric internal flow velocity and local growth of the flue gas velocity. For these reasons, clearly defining the flow pattern in PC boilers is important for solving the problem of tube failure caused by fly ash erosion. For this purpose, the cold air velocity technique (CAVT) can be applied to the fly ash erosion problem. In this study, CAVT was carried out on the Hadong 2 PC boiler and the feasibility of application of CAVT to conventional PC boilers was validated

  4. Cold regions isotope applications

    Perrigo, L.D.; Divine, T.E.

    1976-04-01

    Pacific Northwest Laboratories (PNL) started the Cold Regions Isotope Applications Program in FY-1975 to identify special conditions in the Arctic and similar geographic areas (Cold Regions) where radioisotope power, heater, or sterilization systems would be desirable and economically viable. Significant progress was made in the first year of this program and all objectives for this initial 12-month period were achieved. The major conclusions and recommendations resulting for this effort are described below. The areas of interest covered include: radiosterilization of sewage; heating of septic tanks; and radioisotope thermoelectric generators as power sources for meteorological instruments and navigational aids

  5. Using cold air for reducing needle-injection pain.

    Al-Qarqaz, Firas; Al-Aboosi, Mustafa; Al-shiyab, Diala; Al Dabbagh, Ziad

    2012-07-01

    Pain is associated with skin injections. Reducing injection-associated pain is important especially when multiple injections are needed in difficult areas, such as the palms. We present a new safe application for cold air used in laser therapy. The main objectives of this study are to see whether cold air can reduce needle-injection pain and to evaluate the safety of this new application. Patients undergoing skin injection (n=40) were included. Assessment of pain level using visual analog scale (VAS) was done using cold air and again without cold air in the same patient. Comparison of pain scores was performed. Thirty-three patients had lower VAS scores using cold air. Five patients had worse VAS scores, and two patients did not have any change in their pain score. In the group of patients where injections were made to the palms (n=5), there was even more reduction in VAS scores. There were no significant immediate or delayed side effects. Cold air seems to be useful in reducing needle-injection pain in the majority of patients, especially in the palms. This procedure is safe, apart from immediate tolerable discomfort when used around the nose. © 2012 The International Society of Dermatology.

  6. Cold neutron production and application

    Inoue, Kazuhiko; Watanabe, Noboru.

    1976-01-01

    The first part gives general introduction to cold neutrons, namely the definition and the role as a probe in basic science and technology. The second part reviews various methods of cold neutron production. Some physical characteristics required for cold moderators are presented, and a list summarizes a number of cold moderators and their reactor physics constants. The definition of flux gain factor and the measured values for liquid light- and heavy-hydrogen are also given. The cold neutron spectra in methane and liquid hydrogen measured by LINAC time-of-flight method are presented to show the advantage of solid methane. The cold neutron sources using experimental reactors or linear accelerators are explained along with the examples of existing facilities. Two Japanese programs, the one is the use of a high flux reactor and the other is the use of a LINAC, are also presented. The third part of this report reviews the application areas of cold neutrons. (Aoki, K.)

  7. Indoor air quality in cold climates: hazards and abatement measures

    Walkinshaw, D. S

    1986-01-01

    The first APCA Conference on Indoor Air Quality, held April 29, 30 and May 1, 1985 in Ottawa, featured some 67 presentations covering many aspects of indoor air quality, with the focus on cold climate...

  8. Cold Vacuum Drying Instrument Air System Design Description (SYS 12)

    SHAPLEY, B.J.; TRAN, Y.S.

    2000-06-05

    This system design description (SDD) addresses the instrument air (IA) system of the spent nuclear fuel (SNF). This IA system provides instrument quality air to the Cold Vacuum Drying (CVD) Facility. The IA system is a general service system that supports the operation of the heating, ventilation, and air conditioning (HVAC) system, the process equipment skids, and process instruments in the CVD Facility. The following discussion is limited to the compressor, dryer, piping, and valving that provide the IA as shown in Drawings H-1-82222, Cold Vacuum Drying Facility Mechanical Utilities Compressed & Instrument Air P&ID, and H-1.82161, Cold Vacuum Drying Facility Process Equipment Skid P&ID MCO/Cusk Interface. Figure 1-1 shows the physical location of the 1A system in the CVD Facility.

  9. Cold Vacuum Drying Instrument Air System Design Description. System 12

    SHAPLEY, B.J.; TRAN, Y.S.

    2000-01-01

    This system design description (SDD) addresses the instrument air (IA) system of the spent nuclear fuel (SNF). This IA system provides instrument quality air to the Cold Vacuum Drying (CVD) Facility. The IA system is a general service system that supports the operation of the heating, ventilation, and air conditioning (HVAC) system, the process equipment skids, and process instruments in the CVD Facility. The following discussion is limited to the compressor, dryer, piping, and valving that provide the IA as shown in Drawings H-1-82222, Cold Vacuum Drying Facility Mechanical Utilities Compressed and Instrument Air PandID, and H-1.82161, Cold Vacuum Drying Facility Process Equipment Skid PandID MCO/Cusk Interface. Figure 1-1 shows the physical location of the 1A system in the CVD Facility

  10. Cold air challenge and specific airway resistance in preschool children

    Nielsen, Kim Gjerum; Bisgaard, Hans

    2005-01-01

    prognosis in preschool children. Cold air challenge and plethysmographic measurement of specific airway resistance (sRaw) are feasible candidate methods for diagnosis, clinical monitoring and research during this critical period of lung growth and development. Methodology and practical aspects of cold air...... challenge and assessment of sRaw in preschool children are reviewed. Reference values are provided for sRaw and have allowed discrimination between health and respiratory disease, both in cross-sectional and longitudinal studies. Bronchial hyperresponsiveness can be determined with acceptable repeatability...

  11. Performance enhancement of a subcooled cold storage air conditioning system

    Hsiao, M.-J.; Cheng, C.-H.; Huang, M.-C.; Chen, S.-L.

    2009-01-01

    This article experimentally investigates the enhancement of thermal performance for an air conditioning system utilizing a cold storage unit as a subcooler. The cold storage unit is composed of an energy storage tank, liquid-side heat exchanger, suction-side heat exchanger and energy storage material (ESM), water. When the cooling load is lower than the nominal cooling capacity of the system, the cold storage unit can store extra cold energy of the system to subcool the condenser outlet refrigerant. Hence, both the cooling capacity and coefficient of performance (COP) of the system will be increased. This experiment tests the two operation modes: subcooled mode with energy storage and non-subcooled mode without energy storage. The results show that for fixed cooling loads at 3.05 kW, 3.5 kW and 3.95 kW, the COP of the subcooled mode are 16.0%, 15.6% and 14.1% higher than those of the non-subcooled mode, respectively. In the varied cooling load experiments, the COP of the subcooled cold storage air conditioning system is 15.3% higher than the conventional system.

  12. Applications Using AIRS Data

    Ray, S. E.; Pagano, T. S.; Fetzer, E. J.; Lambrigtsen, B.; Olsen, E. T.; Teixeira, J.; Licata, S. J.; Hall, J. R.; Thompson, C. K.

    2015-12-01

    The Atmospheric Infrared Sounder (AIRS) on NASA's Aqua spacecraft has been returning daily global observations of Earth's atmospheric constituents and properties since 2002. With a 12-year data record and daily, global observations in near real-time, AIRS data can play a role in applications that fall under many of the NASA Applied Sciences focus areas. For vector-borne disease, research is underway using AIRS near surface retrievals to assess outbreak risk, mosquito incubation periods and epidemic potential for dengue fever, malaria, and West Nile virus. For drought applications, AIRS temperature and humidity data are being used in the development of new drought indicators and improvement in the understanding of drought development. For volcanic hazards, new algorithms using AIRS data are in development to improve the reporting of sulfur dioxide concentration, the burden and height of volcanic ash and dust, all of which pose a safety threat to aircraft. In addition, anomaly maps of many of AIRS standard products are being produced to help highlight "hot spots" and illustrate trends. To distribute it's applications imagery, AIRS is leveraging existing NASA data frameworks and organizations to facilitate archiving, distribution and participation in the BEDI. This poster will communicate the status of the applications effort for the AIRS Project and provide examples of new maps designed to best communicate the AIRS data.

  13. High Time Resolution Measurements of VOCs from Vehicle Cold Starts: The Air Toxic Cold Start Pulse

    Jobson, B. T.; Huangfu, Y.; Vanderschelden, G. S.

    2017-12-01

    Pollutants emitted during motor vehicle cold starts, especially in winter in some climates, is a significant source of winter time air pollution. While data exist for CO, NO, and total hydrocarbon emissions from federal testing procedures for vehicle emission certification, little is known about the emission rates of individual volatile organic compounds, in particular the air toxics benzene, formaldehyde, and acetaldehyde. Little is known about the VOC speciation and temperature dependence for cold starts. The US EPA vehicle emission model MOVES assumes that cold start emissions have the same speciation profile as running emissions. We examined this assumption by measuring cold start exhaust composition for 4 vehicles fueled with E10 gasoline over a temperature range of -4°C to 10°C in winter of 2015. The extra cold start emissions were determined by comparison with emissions during engine idling. In addition to CO and NOx measurements a proton transfer reaction mass spectrometer was used to measure formaldehyde, acetaldehyde, benzene, toluene, and C2-alkylbenzenes at high time resolution to compare with the cold start emission speciation profiles used in the EPA MOVES2014 model. The results show that after the vehicle was started, CO mixing ratios can reach a few percent of the exhaust and then drop to several ppmv within 2 minutes of idling, while NOx showed different temporal behaviors among the four vehicles. VOCs displayed elevated levels during cold start and the peak mixing ratios can be two orders higher than idling phase levels. Molar emission ratios relative to toluene were used to compare with the emission ratio used in MOVES2014 and we found the formaldehyde-to-toluene emission ratio was about 0.19, which is 5 times higher than the emission ratio used in MOVES2014 and the acetaldehyde-to-toluene emission ratios were 0.86-0.89, which is 8 times higher than the ones in MOVES2014. The C2-alkylbenzene-to-toluene ratio agreed well with moves. Our results

  14. Logistic advantages of an air curtain in a cold store; Heiploeg ervaart logistieke voordelen van vrieshuis-luchtgordijn

    NONE

    2001-07-01

    Fog and ice are problems in cold storage warehouses. A manufacturer of air conditioning equipment (Biddle in Kootstertille, Netherlands) claims to have found the solution in the so-called Multi Air stream Technology, an air curtain for cold stores.

  15. Heated air humidification versus cold air nebulization in newly tracheostomized patients.

    Birk, Richard; Händel, Alexander; Wenzel, Angela; Kramer, Benedikt; Aderhold, Christoph; Hörmann, Karl; Stuck, Boris A; Sommer, J Ulrich

    2017-12-01

    After tracheostomy, the airway lacks an essential mechanism for warming and humidifying the inspired air with the consequent functional impairment and discomfort. The purpose of this study was to compare airway hydration with cold-air nebulization versus heated high-flow humidification on medical interventions and tracheal ciliary beat frequency (CBF). Newly tracheostomized patients (n = 20) were treated either with cold-air nebulization or heated humidification. The number of required tracheal suctioning procedures to clean the trachea and tracheal CBF were assessed. The number of required suctions per day was significantly lower in the heated humidification group with medians 3 versus 5 times per day. Mean CBF was significantly higher in the heated humidification group (6.36 ± 1.49 Hz) compared to the cold-air nebulization group (3.99 ± 1.39 Hz). The data suggest that heated humidification enhanced mucociliary transport leading to a reduced number of required suctioning procedures in the trachea, which may improve postoperative patient care. © 2017 The Authors Head & Neck Published by Wiley Periodicals, Inc.

  16. Lidar: air pollution applications

    Collis, R.T.H.

    1977-01-01

    This introduction to the use of lidar in air pollution applications is mainly concerned with its capability to detect and monitor atmospheric particulates by elastic backscattering. Even when quite imperceptible to the eye, such particulates may be detected at ranges of several kilometers even by lidars of modest performance. This capability is valuable in connection with air pollution in the following ways: by mapping and tracking inhomogeneities in particulate concentration, atmospheric structure and motion may be monitored; measurements of the optical properties of the atmosphere provide an indication of turbidity or of particulate number or mass concentrations; and the capability of obtaining at a single point return signals from remote atmospheric volumes makes it possible to make range-resolved measurements of gaseous concentration along the path by using the resonant absorption of energy of appropriate wavelengths

  17. Modeling a cold-air drainage event with a wireless sensor network

    Brian R. Zutta; Eric A. Graham; Philip W. Rundel

    2005-01-01

    A wireless network of sensors was used to characterize a cold-air drainage event in the canyon surrounding the James Reserve. The flow of cold air at night and the first hours of sunrise have major ecological consequences by limiting the vegetation types to those tolerant of freeze and thaw cycles. A network of wireless sensors provides the opportunity to track this event in real time and fully characterize the cold air flow down the canyon, which may last 1.5 hours, and the pooling of cold a...

  18. New options for the cold storage air curtain in the food sector; Koelruimte-luchtgordijn biedt nieuwe mogelijkheden

    Bruins, K. [Biddle, Kootstertille (Netherlands)

    1997-10-01

    Based on a newly developed so-called multi air jet technology air curtains in front of cold spaces prevent warm air from infiltrating the cold space. The principles and performance of the cold space air curtain are briefly outlined. 2 figs.

  19. Evaluation of simplified ventilation system with direct air supply through the facade in a school in a cold climate

    Mysen, M. [Norwegian Building Research Institute, Blindern, Oslo (Norway); Department of Energy and Process Technology, Norwegian University of Science and Technology (NTNU), Trondheim (Norway); Schild, P. G.; Hellstrand, V.; Thunshelle, K. [Norwegian Building Research Institute, Blindern, Oslo (Norway)

    2004-07-01

    Many educational buildings in industrialised countries have poor indoor climate, according to today's knowledge about the impact of indoor climate on well-being and productivity. Budget restrictions and practical limitations such as lack of space for central air handling units and ventilation ducts, have motivated the application of simplified ventilation systems in some schools, such as taking unconditioned supply air directly from the facade. One such school was recently evaluated in Norway. On cold days, thermal comfort in the classroom deteriorated due to cold down draught from the supply outlet. In addition, moist and fertile conditions for microbiological growth were observed in the air supply ductwork. On the other hand the same pupils are more satisfied with the school and have less sick building syndrome (SBS) symptoms during winter than summer. An improved control strategy with a temperature-compensated CO{sub 2} set-point for controlling the air flow is suggested. This could improve thermal comfort and reduce energy use without compromising perceived air quality (PAQ) during cold weather. Furthermore it could improve indoor air quality (IAQ) during warm weather with only a slight increase of energy use. Further evaluation of an improved solution is needed before such a ventilation concept can be recommended in cold climates. (author)

  20. Advanced cold rolled steels for automotive applications

    Hofmann, H. [ThyssenKrupp Steel AG, Eberhardstrasse 12, 44145 Dortmund (Germany); Mattissen, D.; Schaumann, T.W. [ThyssenKrupp Steel AG, Duisburg (Germany)

    2006-09-15

    Advanced multiphase steels offer a great potential for bodies-in-white through their combination of formability and achievable component strength levels. They are first choice for strength and crash-relevant parts of challenging geometry. The intensive development of high-strength multiphase steels by ThyssenKrupp has led to hot dip galvanizing concepts with an outstanding forming potential. Hot rolled, hot dip galvanized complex phase steels are currently produced in addition to cold rolled DP and RA steels. New continuously annealed grades with tensile strength levels of up to 1000 MPa in combination with sufficient ductility for applications mainly in the field of structural automobile elements make use of the classic advantages of microalloying as well as the principles of DP and TRIP steels. Further improvement of properties will be reached by the new class of high manganese alloyed steels. (Abstract Copyright [2006], Wiley Periodicals, Inc.) [German] Fortschrittliche Multiphasen-Staehle eroeffnen wegen der inzwischen erreichbaren Kombination aus Umformbarkeit und Bauteilfestigkeit ein enormes Potenzial fuer Rohkarosserien. Sie stellen eine erste Wahl dar, wenn es um Festigkeit und um Crashsicherheit geht und besondere Anforderungen an die Bauteilgeometrien gestellt werden. Bei ThyssenKrupp hat die Entwicklung hochfester Multiphasen-Staehle in Verbindung mit dem Feuerverzinken zur Realisierung von Blechhalbzeugen gefuehrt, die hervorragend formbar sind. Es werden heute feuerverzinkte Komplexphasenstaehle neben den bewaehrten kaltgewalzten Dualphasen(DP) - und Retained Austenit(RA)-Staehlen produziert. Die neuen kontinuierlich gegluehten Stahlvarianten mit Festigkeiten bis zu 1000 MPa in Kombination mit der bei Strukturbauteilen im Automobilbau geforderten Duktilitaet nutzen sowohl die klassischen Vorteile des Mikrolegierens aus und dazu die Prinzipien, die man bei DP- und TRIP-Staehlen anwendet. Eine weitere Verbesserung des Eigenschaftsprofils wird mit dem

  1. Potential application of glazed transpired collectors to space heating in cold climates

    Gao, Lixin; Bai, Hua; Mao, Shufeng

    2014-01-01

    Highlights: • A mathematical model for glazed transpired collectors (GTC) is developed. • Glazing results in optical loss, but it decreases convective heat loss effectively. • Thermal performance of GTC shows considerable improvement on flat-plate collectors. • GTC using recirculated air is applicable to space heating in cold climates. - Abstract: Although unglazed transpired collectors (UTC) succeed in industrial ventilation applications, solar fraction is very low when they are used in space heating in cold climates due to the lower exit air temperature. Considering the potential for glazed transpired collectors (GTC) using recirculated air for space heating applications in cold climates, a mathematical model is developed for predicting the thermal performance of GTC. Simulation results show that although glazing results in optical loss, it could decrease convective heat loss resulted from high crosswind velocities effectively. For a solar radiation of 400 W/m 2 , an ambient temperature of −10 °C, and a suction velocity of 0.01 m/s, the exit air temperature of GTC is higher than that of UTC for crosswind velocities exceeding 3.0 m/s. By comparison with a conventional flat-plate solar air collector operating under the same conditions, the thermal performance of GTC shows a significant improvement. For a five-storey hotel building located in the severe cold climate zone of China, case study shows that the annual solar fraction of the GTC-based solar air heating system is about 20%, which is two times higher than that of the flat-plate collector-based system and nearly nine times higher than that of the UTC-based system respectively. Hence, an enormous amount of energy will be saved with the application of GTC to space heating in cold climates

  2. Cold neutron interferometry and its application. 2. Coherency and cold neutron spin interferometry

    Achiwa, Norio; Ebisawa, Toru

    1998-03-01

    The second workshop entitled 'Interference studies and cold neutron spin interferometry' was held on 10 and 11 March 1998 at KUR (Kyoto University Research Reactor Institute, Kumatori). Cold neutron spin interferometry is a new field. So it is very important for its development to learn the studies of X-ray and neutron optics which are rapidly developing with long history. In the workshop, the issues related to interference were reviewed such as experimental studies on cold neutron spin interferometry, theoretical and experimental approach on tunneling time, interference experiments by neutrons and its application, interference studies using synchrotron radiation, topics on silicon interferometry and quantum measurement problem and cold neutron interference experiment related to quantum measurement problem. The 8 of the presented papers are indexed individually. (J.P.N.)

  3. Powder consolidation using cold spray process modeling and emerging applications

    Moridi, Atieh

    2017-01-01

    This book first presents different approaches to modeling of the cold spray process with the aim of extending current understanding of its fundamental principles and then describes emerging applications of cold spray. In the coverage of modeling, careful attention is devoted to the assessment of critical and erosion velocities. In order to reveal the phenomenological characteristics of interface bonding, severe, localized plastic deformation and material jet formation are studied. Detailed consideration is also given to the effect of macroscopic defects such as interparticle boundaries and subsequent splat boundary cracking on the mechanical behavior of cold spray coatings. The discussion of applications focuses in particular on the repair of damaged parts and additive manufacturing in various disciplines from aerospace to biomedical engineering. Key aspects include a systematic study of defect shape and the ability of cold spray to fill the defect, examination of the fatigue behavior of coatings for structur...

  4. Détente from the Air: Monitoring Air Pollution during the Cold War.

    Rothschild, Rachel

    During the period of détente in the 1970s, a Norwegian proposal to construct an air pollution monitoring network for the European continent resulted in the first concrete collaboration between the communist and capitalist blocs after the 1975 Helsinki Accords. Known as the "European-wide monitoring programme" or EMEP, the network earned considerable praise from diplomats for facilitating cooperation across the Iron Curtain. Yet as this article argues, EMEP was strongly influenced by the politics of détente and the constraints of the Cold War even as it helped to decrease tensions. Concerns about national security and sharing data with the enemy shaped both the construction of the monitoring network and the modeling of pollution transport. The article also proposes that environmental monitoring systems like EMEP reveal the ways in which observational technologies can affect conceptions of the natural world and the role of science in public policy.

  5. Winter sports athletes: long-term effects of cold air exposure.

    Sue-Chu, Malcolm

    2012-05-01

    Athletes such as skaters and skiers inhale large volumes of cold air during exercise and shift from nasal to mouth breathing. Endurance athletes, like cross-country skiers, perform at 80% or more of their maximal oxygen consumption and have minute ventilations in excess of 100 l/min. Cold air is always dry, and endurance exercise results in loss of water and heat from the lower respiratory tract. In addition, athletes can be exposed to indoor and outdoor pollutants during the competitive season and during all-year training. Hyperpnoea with cold dry air represents a significant environmental stress to the airways. Winter athletes have a high prevalence of respiratory symptoms and airway hyper-responsiveness to methacholine and hyperpnoea. The acute effects of exercise in cold air are neutrophil influx as demonstrated in lavage fluid and airway epithelial damage as demonstrated by bronchoscopy. Upregulation of pro-inflammatory cytokines has been observed in horses. Chronic endurance training damages the epithelium of the small airways in mice. Airway inflammation has been observed on bronchoscopy of cross-country skiers and in dogs after a 1100-mile endurance race in Alaska. Neutrophilic and lymphocytic inflammation with remodelling is present in bronchial biopsies from skiers. Repeated peripheral airway hyperpnoea with dry air causes inflammation and remodelling in dogs. As it is currently unknown if these airway changes are reversible upon cessation of exposure, preventive measures to diminish exposure of the lower airways to cold air should be instituted by all winter sports athletes.

  6. Using cold battery with icy water as an alternative method of air ...

    The aim of this work is to reduce the energy consumption of a passenger ship by using an air conditioning system with a solar energy source. This technique is applied on ships with a cold room with a refrigeration unit. The work consists of using a central air conditioning system for which a heat exchanger is placed in the ...

  7. Hyperventilation with cold versus dry air in 2- to 5-year-old children with asthma

    Nielsen, Kim G; Bisgaard, Hans

    2005-01-01

    UNLABELLED: Cold air challenge (CACh) has been shown to discriminate between children with asthma and healthy young children. Hyperventilation with dry room-temperature air is a simplified alternative. We compared responsiveness in young children with asthma between two standardized, single......-subject SDs (SDw). The challenge sequence was randomly assigned. A comparator challenge was performed 1 hour later if the first challenge gave a change of 3 SDw or more. Forty 2- to 5-year-old children with asthma were included. Responsiveness to cold versus dry air showed significant, but weak, correlation...

  8. Adsorption cold storage system with zeolite-water working pair used for locomotive air conditioning

    Lu, Y.Z.; Wang, R.Z.; Zhang, M.; Jiangzhou, S.

    2003-01-01

    Adsorption cold storage has lately attracted attention for its large storage capacity and zero cold energy loss during the storing process. Thermodynamic and experimental studies on the cold storage capacity and the cold discharging process, in which the adsorber is either air cooled or adiabatic, have been presented. An adsorption cold storage system with zeolite-water working pair has been developed, and some operating results are summarized. This system is used for providing air conditioning for the driver's cab of an internal combustion locomotive. Unlike a normal adsorption air conditioner, the system starts running with the adsorption process, during which the cold energy stored is discharged, and ends running with the generation process. The adsorbent temperature decreases during the cold storing period between two runs. The refrigeration power output for the whole running cycle is about 4.1 kW. It appears that such a system is quite energetically efficient and is comparatively suitable for providing discontinuous refrigeration capacity when powered by low grade thermal energy, such as industrial exhausted heat or solar energy

  9. Advanced cold rolled steels for automotive applications

    Hofmann, Harald; Mattissen, Dorothea; Schaumann, Thomas Wilhelm [ThyssenKrupp Steel AG, Center of Materials Excellence, Dortmund (Germany)

    2009-01-15

    Advanced high-strength steels offer a great potential for the further development of automobile bodies-in-white due to their combined mechanical properties of high formability and strength. They represent the first choice in material selection for strength and crash-relevant parts with challenging geometries. The intensive development of multiphase steels by ThyssenKrupp Steel has led to hot dip galvanizing concepts with an outstanding forming potential. Hot rolled, hot dip galvanized complex-phase steels are currently produced in addition to cold rolled dual phase (DP) and retained austenite (RA) or transformation induced plasticity (TRIP) steels. New continuously annealed grades of steel are being developed with tensile strength levels of up to 1000 MPa in combination with sufficient ductility for the high demands of structural automobile components. These steels make use of the classic advantages of microalloying as well as the principles of DP steels and RA / TRIP steels. Further improvement of properties will be reached by the new class of high manganese alloyed steels. (orig.)

  10. Cold-inducible RNA-binding protein mediates cold air inducible airway mucin production through TLR4/NF-κB signaling pathway.

    Chen, Lingxiu; Ran, Danhua; Xie, Wenyue; Xu, Qing; Zhou, Xiangdong

    2016-10-01

    Mucus overproduction is an important feature in patients with chronic inflammatory airway diseases and cold air stimulation has been shown to be associated with the severity of these diseases. However, the regulatory mechanisms that mediate excessive mucin production under cold stress remain elusive. Recently, the cold-inducible RNA-binding protein (CIRP) has been shown to be markedly induced after exposure to cold air. In this study, we sought to explore the expression of CIRP within bronchial biopsy specimens, the effect on mucin5AC (MUC5AC) production in chronic inflammatory airway diseases and the potential signaling pathways involved in cold air stimulation process. We found that CIRP protein expression was significantly increased in patients with COPD and in mice treated with cold air. Moreover, cold air stimulation induced MUC5AC expression in wild-type mice but not in CIRP(-/-) mice. In vitro, cold air stress significantly elevated the transcriptional and protein expression levels of MUC5AC in human bronchial epithelial cells. CIRP, toll-like receptor 4 (TLR4) and phosphorylated NF-κB p65 (p-p65) increased significantly in response to cold stress and CIRP siRNA, TLR4 - neutralizing Ab and a specific inhibitor of NF-κB could attenuated cold stress inducible MUC5AC expression. In addition, CIRP siRNA could hindered the expression levels of TLR4 and p-p65 both induced by cold stress. Taken together, these results suggest that airway epithelial cells constitutively express CIRP in vitro and in vivo. CIRP is responsible for cold-inducible MUC5AC expression by activating TLR4/NF-κB signaling pathway. Copyright © 2016 Elsevier B.V. All rights reserved.

  11. Cold and ultracold molecules: science, technology and applications

    Carr, Lincoln D; DeMille, David; Krems, Roman V; Ye Jun

    2009-01-01

    This paper presents a review of the current state of the art in the research field of cold and ultracold molecules. It serves as an introduction to the focus issue of New Journal of Physics on Cold and Ultracold Molecules and describes new prospects for fundamental research and technological development. Cold and ultracold molecules may revolutionize physical chemistry and few-body physics, provide techniques for probing new states of quantum matter, allow for precision measurements of both fundamental and applied interest, and enable quantum simulations of condensed-matter phenomena. Ultracold molecules offer promising applications such as new platforms for quantum computing, precise control of molecular dynamics, nanolithography and Bose-enhanced chemistry. The discussion is based on recent experimental and theoretical work and concludes with a summary of anticipated future directions and open questions in this rapidly expanding research field.

  12. Experimental validation of a local dehumidification system based on cold water droplets and air-to-air heat exchanger

    Janssen, E.G.O.N.; Hammink, H.A.J.; Hendriksen, L.J.A.M.

    2015-01-01

    Excessive humidity is a problem in Dutch growing circumstances. A traditional solution is heating and natural ventilation. To save energy a number of energy efficient dehumidification methods are developed, like mechanical ventilation with dry outside air or a curtain of cold water droplets. In this

  13. Superstructures: First Cold Test and Future Applications

    J. Sekutowicz; C Albrecht; V Ayvazyan; R Bandelmann; T Buttner; P Castro; S Choroba; J Eschke; B Faatz; A Gossel; K Honkavaara; B Horst; J Iverson; K Jensch; H Kaiser; R Kammering; G Kreps; D Kostin; J Lorkiewicz; R Lange; A Matheisen; W -D Moller; H -B Peters; D Proch; K Rehlich; H Schlarb; S Schrieber; D Reschke; S Simrock; W Singer; X Singer; K Twarowski; T Weichert; M Wojtkiewicz; G Wendt; K Zapfe; M Liepe; M Huening; M Ferrario; E Plawski; C Pagani; P Kneisel; G Wu; N Baboi; C Thomas; H Chen; W Huang; C Tang; S Zheng

    2003-01-01

    Superstructures, chains of superconducting multi-cell cavities (subunits) connected by e/2 long tube(s) have been proposed as an alternative layout for the TESLA main accelerator [1]. After three years of preparation, two superstructures, each made of two weakly coupled superconducting 7-cell subunits driven by a single Fundamental Power Coupler (FPC), have been installed in the Tesla Test Facility linac for beam tests. Energy stability, HOM damping, frequency and field adjustment methods were tested. The measured results confirme Superstructures, chains of superconducting multi-cell cavities (subunits) connected by e/2 long tube(s) have been proposed as an alternative layout for the TESLA main accelerator [1]. After three years of preparation, two superstructures, each made of two weakly coupled superconducting 7-cell subunits driven by a single Fundamental Power Coupler (FPC), have been installed in the Tesla Test Facility linac for beam tests. Energy stability, HOM damping, frequency and field adjustment methods were tested. The measured results confirmed expectation on the superstructure performance and proved that an alternative layout for the 800 GeV upgrade of the TESLA collider is feasible. We report on the test and give here an overview of its results. The tests confirmed very good damping of HOMs in superstructures and thus has opened a possible new application of this concept to high current energy recovery machines. We have built two 1.5 GHz copper models of two superstructures: 2x5-cells and 2x2-cells to prove further improvement of HOM damping. This contribution presents also measured results on these models. d expectations on the superstructure performance and proved that an alternative layout for the 800 GeV upgrade of the TESLA collider is feasible. We report on the test and give here an overview of its results

  14. Cold atmospheric air plasma sterilization against spores and other microorganisms of clinical interest.

    Klämpfl, Tobias G; Isbary, Georg; Shimizu, Tetsuji; Li, Yang-Fang; Zimmermann, Julia L; Stolz, Wilhelm; Schlegel, Jürgen; Morfill, Gregor E; Schmidt, Hans-Ulrich

    2012-08-01

    Physical cold atmospheric surface microdischarge (SMD) plasma operating in ambient air has promising properties for the sterilization of sensitive medical devices where conventional methods are not applicable. Furthermore, SMD plasma could revolutionize the field of disinfection at health care facilities. The antimicrobial effects on Gram-negative and Gram-positive bacteria of clinical relevance, as well as the fungus Candida albicans, were tested. Thirty seconds of plasma treatment led to a 4 to 6 log(10) CFU reduction on agar plates. C. albicans was the hardest to inactivate. The sterilizing effect on standard bioindicators (bacterial endospores) was evaluated on dry test specimens that were wrapped in Tyvek coupons. The experimental D(23)(°)(C) values for Bacillus subtilis, Bacillus pumilus, Bacillus atrophaeus, and Geobacillus stearothermophilus were determined as 0.3 min, 0.5 min, 0.6 min, and 0.9 min, respectively. These decimal reduction times (D values) are distinctly lower than D values obtained with other reference methods. Importantly, the high inactivation rate was independent of the material of the test specimen. Possible inactivation mechanisms for relevant microorganisms are briefly discussed, emphasizing the important role of neutral reactive plasma species and pointing to recent diagnostic methods that will contribute to a better understanding of the strong biocidal effect of SMD air plasma.

  15. Nasal mucosa secretion exudation response to cold air in bronchial asthma patients

    Eduard V. Nekrasov

    2017-01-01

    Full Text Available Background. Combined airway hyper responsiveness to cold and hypoosmotic stimuli in asthma patients results in impairment of lung respiration function and poor disease control compared to patients with isolated airway hyper responsiveness to only one of the stimuli or without such responsiveness that can be connected with edema or mucus hypersecretion.Aim. The purpose of the study is the estimation of the processes of mucin secretion, plasma exudation and oxidative stress in response to cold air in asthma patients with combined airway responsiveness to cold and hypoosmotic stimuli using nasal mucosa as a model.Materials and methods. 23 patients with asthma participated in the study. For the nasal lavage procedure, a nasal cavity was pre-washed at least three times in 5-min intervals with 5 ml saline solution (~36 °C. A control nasal lavage was done 5 min after the last washing with a dwelling time of 1 min in the nasal cavity. Directly after the control lavage, a cold air nasal challenge was done: a participant was asked to breathe deeply at the pace of a metronome to ensure hyperventilation inhaling cold air (–20 °C through the nose and exhaling through the mouth for 5 min. Nasal lavages were taken at 1 min, 15, and 30 min after the challenge. Mucin secretion was estimated on the basis of total protein (TP content, total carbohydrates (TC, and water-soluble forms of mucins MUC5AC and MUC5B in the lavage fluids. For the estimation of plasma exudation, the concentration of α2-macroglobulin (α2-MG was measured. Oxidative stress was estimated by the content of thiobarbituric acid-reactive substances (TBARS in lavage fluid. Lung function and airway responsiveness were studied by the forced expiration spirometry method and the bronchial challenge tests with isocapnic cold air hyperventilation (CAHV and distilled water inhalation (DWI.Results. According to the bronchial challenge tests, the patients were divided into groups: 1 without airway

  16. Curriculum Evolution at Air Command and Staff College in the Post-Cold War Era

    Donovan, William Robert, II.

    2010-01-01

    This qualitative study used a historical research method to eliminate the gap in the historical knowledge of Air Command and Staff College (ACSC) curriculum evolution in the post-Cold War era. This study is the only known analysis of the forces that influenced the ACSC curriculum and the rationale behind curricular change at ACSC in the post-Cold…

  17. Retrofitting Forced Air Combi Systems: A Cold Climate Field Assessment

    Schoenbauer, Ben [NorthernSTAR, St. Paul, MN (United States); Bohac, Dave [NorthernSTAR, St. Paul, MN (United States); McAlpine, Jack [NorthernSTAR, St. Paul, MN (United States); Hewett, Martha [NorthernSTAR, St. Paul, MN (United States)

    2017-06-01

    This project analyzed combined condensing water heaters or boilers and hydronic air coils to provide high efficiency domestic hot water (DHW) and forced air space heating. Called "combi" systems, they provided similar space and water heating performance less expensively than installing two condensing appliances. The system's installed costs were cheaper than installing a condensing furnace and either a condensing tankless or condensing storage water heater. However, combi costs must mature and be reduced before they are competitive with a condensing furnace and power vented water heater (energy factor of 0.60). Better insulation and tighter envelopes are reducing space heating loads for new and existing homes. For many homes, decreased space heating loads make it possible for both space and domestic water heating loads to be provided with a single heating plant. These systems can also eliminate safety issues associated with natural draft appliances through the use of one common sealed combustion vent. The combined space and water heating approach was not a new idea. Past systems have used non-condensing heating plants, which limited their usefulness in climates with high heating loads. Previous laboratory work (Schoenbauer et al. 2012a) showed that proper installation was necessary to achieve condensing with high efficiency appliances. Careful consideration was paid to proper system sizing and minimizing the water temperature returning from the air handling unit to facilitate condensing operation.

  18. Retrofitting Forced Air Combi Systems: A Cold Climate Field Assessment

    Schoenbauer, Ben [Univ. of Minnesota, St. Paul, MN (United States). NorthernSTAR Building America Partnership; Bohac, Dave [Univ. of Minnesota, St. Paul, MN (United States). NorthernSTAR Building America Partnership; McAlpine, Jake [Univ. of Minnesota, St. Paul, MN (United States). NorthernSTAR Building America Partnership; Hewett, Martha [Univ. of Minnesota, St. Paul, MN (United States). NorthernSTAR Building America Partnership

    2017-06-23

    This project analyzed combined condensing water heaters or boilers and hydronic air coils to provide high efficiency domestic hot water (DHW) and forced air space heating. Called 'combi' systems, they provided similar space and water heating performance less expensively than installing two condensing appliances. The system's installed costs were cheaper than installing a condensing furnace and either a condensing tankless or condensing storage water heater. However, combi costs must mature and be reduced before they are competitive with a condensing furnace and power vented water heater (energy factor of 0.60). Better insulation and tighter envelopes are reducing space heating loads for new and existing homes. For many homes, decreased space heating loads make it possible for both space and domestic water heating loads to be provided with a single heating plant. These systems can also eliminate safety issues associated with natural draft appliances through the use of one common sealed combustion vent. The combined space and water heating approach was not a new idea. Past systems have used non-condensing heating plants, which limited their usefulness in climates with high heating loads. Previous laboratory work (Schoenbauer et al. 2012a) showed that proper installation was necessary to achieve condensing with high efficiency appliances. Careful consideration was paid to proper system sizing and minimizing the water temperature returning from the air handling unit to facilitate condensing operation.

  19. [Influence of industrial pollution of ambient air on health of workers engaged into open air activities in cold conditions].

    Chashchin, V P; Siurin, S A; Gudkov, A B; Popova, O N; Voronin, A Iu

    2014-01-01

    The article presents the results of a study on assessment of occupational exposure to air pollutants and related health effects in3792 outdoor workers engaged in operations performed in the vicinity of non-ferrous metallurgical facilities in Far North. Findings are that during cold season repeated climate and weather conditions are associated with higher level of chemical hazards and dust in surface air. At the air temperature below -17 degrees C, maximal single concentrations of major pollutants can exceed MAC up to 10 times. With that, transitory disablement morbidity parameters and occupational accidents frequency increase significantly. The workers with long exposure to cooling meteorological factors and air pollution demonstrate significantly increased prevalence of respiratory and circulatory diseases, despite relatively low levels of sculpture dioxide and dust in the air, not exceeding the occupational exposure limits. It has been concluded that severe cold is to be considered asa factor increasing occupational risk at air polluted outdoor worksites dueto more intense air pollution, higher traumatism risk and lower efficiency of filter antidust masks respiratory PPE and due to modification of the toxic effects.

  20. Inversion Build-Up and Cold-Air Outflow in a Small Alpine Sinkhole

    Lehner, Manuela; Whiteman, C. David; Dorninger, Manfred

    2017-06-01

    Semi-idealized model simulations are made of the nocturnal cold-air pool development in the approximately 1-km wide and 100-200-m deep Grünloch basin, Austria. The simulations show qualitatively good agreement with vertical temperature and wind profiles and surface measurements collected during a meteorological field expedition. A two-layer stable atmosphere forms in the basin, with a very strong inversion in the lowest part, below the approximate height of the lowest gap in the surrounding orography. The upper part of the stable layer is less strongly stratified and extends to the approximate height of the second-lowest gap. The basin atmosphere cools most strongly during the first few hours of the night, after which temperatures decrease only slowly. An outflow of air forms through the lowest gap in the surrounding orography. The outflow connects with a weak inflow of air through a gap on the opposite sidewall, forming a vertically and horizontally confined jet over the basin. Basin cooling shows strong sensitivity to surface-layer characteristics, highlighting the large impact of variations in vegetation and soil cover on cold-air pool development, as well as the importance of surface-layer parametrization in numerical simulations of cold-air-pool development.

  1. Cold Vacuum Drying facility heating, ventilation, and Air Conditioning system design description

    SINGH, G.

    2000-01-01

    This System Design Description (SDD) addresses the HVAC system for the CVDF. The CVDF HVAC system consists of five subsystems: (1) Administration building HVAC system; (2) Process bay recirculation HVAC system; (3) Process bay local exhaust HVAC and process vent system; (4) Process general supply/exhaust HVAC system; and (5) Reference air system. The HVAC and reference air systems interface with the following systems: the fire protection control system, Monitoring and Control System (MCS), electrical power distribution system (including standby power), compressed air system, Chilled Water (CHW) system, drainage system, and other Cold Vacuum Drying (CVD) control systems not addressed in this SDD

  2. Inactivation of Staphylococcus aureus and Enterococcus faecalis by a direct-current, cold atmospheric-pressure air plasma microjet☆

    Tian, Ye; Sun, Peng; Wu, Haiyan; Bai, Na; Wang, Ruixue; Zhu, Weidong; Zhang, Jue; Liu, Fuxiang

    2010-01-01

    Objective A direct-current, cold atmospheric-pressure air plasma microjet (PMJ) was performed to inactivate Staphylococcus aureus (S. aureus) and Enterococcus faecalis (E. faecalis) in air. The process of sterilization and morphology of bacteria was observed. We wish to know the possible inactivation mechanisms of PMJ and explore a potential application in dental and other temperature sensitive treatment. Methods In this study, we employed a direct current, atmospheric pressure, cold air PMJ to inactivate bacterias. Scanning electron microscopy was employed to evaluate the morphology of S. aureus and showed rupture of cell walls after the plasma treatment and Optical emission spectrum (OES) were used to understand the possible inactivation mechanisms of PMJ. Results The inactivation rates could reach 100% in 5 min. When the distance between the exit nozzle of the PMJ device and Petri dish was extended from 1 cm to 3 cm, effective inactivation was also observed with a similar inactivation curve. Conclusion The inactivation of bacteria is attributed to the abundant reactive oxygen and nitrogen species, as well as ultroviolet radiation in the plasma. Different life spans and defensibilities of these killing agents may hold the key to understanding the different inactivation curves at different treatment distances. PMID:23554639

  3. Inactivation of Staphylococcus aureus and Enterococcus faecalis by a direct-current, cold atmospheric-pressure air plasma microjet.

    Tian, Ye; Sun, Peng; Wu, Haiyan; Bai, Na; Wang, Ruixue; Zhu, Weidong; Zhang, Jue; Liu, Fuxiang

    2010-07-01

    A direct-current, cold atmospheric-pressure air plasma microjet (PMJ) was performed to inactivate Staphylococcus aureus (S. aureus) and Enterococcus faecalis (E. faecalis) in air. The process of sterilization and morphology of bacteria was observed. We wish to know the possible inactivation mechanisms of PMJ and explore a potential application in dental and other temperature sensitive treatment. In this study, we employed a direct current, atmospheric pressure, cold air PMJ to inactivate bacterias. Scanning electron microscopy was employed to evaluate the morphology of S. aureus and showed rupture of cell walls after the plasma treatment and Optical emission spectrum (OES) were used to understand the possible inactivation mechanisms of PMJ. The inactivation rates could reach 100% in 5 min. When the distance between the exit nozzle of the PMJ device and Petri dish was extended from 1 cm to 3 cm, effective inactivation was also observed with a similar inactivation curve. The inactivation of bacteria is attributed to the abundant reactive oxygen and nitrogen species, as well as ultroviolet radiation in the plasma. Different life spans and defensibilities of these killing agents may hold the key to understanding the different inactivation curves at different treatment distances.

  4. Cold, dry air is associated with influenza and pneumonia mortality in Auckland, New Zealand.

    Davis, Robert E; Dougherty, Erin; McArthur, Colin; Huang, Qiu Sue; Baker, Michael G

    2016-07-01

    The relationship between weather and influenza and pneumonia mortality was examined retrospectively using daily data from 1980 to 2009 in Auckland, New Zealand, a humid, subtropical location. Mortality events, defined when mortality exceeded 0·95 standard deviation above the mean, followed periods of anomalously cold air (ta.m. = -4·1, P < 0·01; tp.m. = -4·2, P < 0·01) and/or anomalously dry air (ta.m. = -4·1, P < 0·01; tp.m. = -3·8, P < 0·01) by up to 19 days. These results suggest that respiratory infection is enhanced during unusually cold conditions and during conditions with unusually low humidity, even in a subtropical location where humidity is typically high. © 2015 The Authors. Influenza and Other Respiratory Viruses Published by John Wiley & Sons Ltd.

  5. Solar air heaters and their applications

    Selcuk, M. K.

    1977-01-01

    The solar air heater appears to be the most logical choice, as far as the ultimate application of heating air to maintain a comfortable environment is concerned. One disadvantage of solar air heaters is the need for handling larger volumes of air than liquids due to the low density of air as a working substance. Another disadvantage is the low thermal capacity of air. In cases where thermal storage is needed, water is superior to air. Design variations of solar air heaters are discussed along with the calculation of the efficiency of a flat plate solar air heater, the performance of various collector types, and the applications of solar air heaters. Attention is given to collectors with nonporous absorber plates, collectors with porous absorbers, the performance of flat plate collectors with finned absorbers, a wire mesh absorber, and an overlapped glass plate air heater.

  6. Performance of introducing outdoor cold air for cooling a plant production system with artificial light

    Jun eWang

    2016-03-01

    Full Text Available The commercial use of a plant production system with artificial light (PPAL is limited by its high initial construction and operation costs. The electric-energy consumed by heat pumps, applied mainly for cooling, accounts for 15-35% of the total electric-energy used in a PPAL. To reduce the electric-energy consumption, an air exchanger with low capacity (180 W was used for cooling by introducing outdoor cold air. In this experiment, the indoor air temperature in two PPALs (floor area: 6.2 m2 each was maintained at 25ºC and 20ºC during light and dark periods, respectively, for lettuce production. In one PPAL (PPALe, an air exchanger (air flow rate: 250 m3 h-1 was used along with a heat pump (cooling capacity: 3.2 kW to maintain the indoor air temperature at the set-point. The other PPAL (PPALc with only a heat pump (cooling capacity: 3.2 kW was used for reference. Effects of introducing outdoor cold air on energy use efficiency, coefficient of performance (COP, electric-energy consumption for cooling and growth of lettuce were investigated. The results show that: when the air temperature difference between indoor and outdoor ranged from 20.2°C to 30.0°C: 1 the average energy use efficiency of the air exchanger was 2.8 and 3.4 times greater than the COP of the heat pumps in the PPALe and PPALc, respectively; 2 hourly electric-energy consumption in the PPALe reduced by 15.8-73.7% compared with that in the PPALc; 3 daily supply of CO2 in the PPALe reduced from 0.15 kg to 0.04 kg compared with that in the PPALc; 4 no significant difference in lettuce growth was observed in both PPALs. The results indicate that using air exchanger to introduce outdoor cold air should be considered as an effective way to reduce electric-energy consumption for cooling with little effects on plant growth in a PPAL.

  7. Synoptic climatological analysis of persistent cold air pools over the Carpathian Basin

    Szabóné André, Karolina; Bartholy, Judit; Pongrácz, Rita

    2016-04-01

    A persistent cold air pool (PCAP) is a winter-time, anticyclone-related weather event over a relatively large basin. During this time the air is colder near the surface than aloft. This inversion near the surface can last even for weeks. As the cold air cools down, relative humidity increases and fog forms. The entire life cycle of a PCAP depends on the large scale circulation pattern. PCAP usually appears when an anticyclone builds up after a cold front passed over the examined basin, and it is usually destructed by a coming strong cold front of another midlatitude cyclone. Moreover, the intensity of the anticyclone affects the intensity of the PCAP. PCAP may result in different hazards for the population: (1) Temperature inversion in the surface layers together with weak wind may lead to severe air pollution causing health problems for many people, especially, elderly and children. (2) The fog and/or smog during chilly weather conditions often results in freezing rain. Both fog and freezing rain can distract transportation and electricity supply. Unfortunately, the numerical weather prediction models have difficulties to predict PCAP formation and destruction. One of the reasons is that PCAP is not defined objectively with a simple formula, which could be easily applied to the numerical output data. However, according to some recommendations from the synoptic literature, the shallow convective potential energy (SCPE) can be used to mathematically describe PCAP. In this study, we used the ERA-Interim reanalysis datasets to examine this very specific weather event (i.e., PCAP) over the Carpathian Basin. The connection between the mean sea level pressure and some PCAP measures (e.g., SCPE, energy deficit, etc.) is evaluated. For instance, we used logistic regression to identify PCAP periods over the Carpathian Basin. Then, further statistical analysis includes the evaluation of the length and intensity of these PCAP periods.

  8. Simulation of a Novel Single-column Cryogenic Air Separation Process Using LNG Cold Energy

    Jieyu, Zheng; Yanzhong, Li; Guangpeng, Li; Biao, Si

    In this paper, a novel single-column air separation process is proposed with the implementation of heat pump technique and introduction of LNG coldenergy. The proposed process is verifiedand optimized through simulation on the Aspen Hysys® platform. Simulation results reveal that thepower consumption per unit mass of liquid productis around 0.218 kWh/kg, and the total exergy efficiency of the systemis 0.575. According to the latest literatures, an energy saving of 39.1% is achieved compared with those using conventional double-column air separation units.The introduction of LNG cold energy is an effective way to increase the system efficiency.

  9. Cold air plasma to decontaminate inanimate surfaces of the hospital environment.

    Cahill, Orla J; Claro, Tânia; O'Connor, Niall; Cafolla, Anthony A; Stevens, Niall T; Daniels, Stephen; Humphreys, Hilary

    2014-03-01

    The hospital environment harbors bacteria that may cause health care-associated infections. Microorganisms, such as multiresistant bacteria, can spread around the patient's inanimate environment. Some recently introduced biodecontamination approaches in hospitals have significant limitations due to the toxic nature of the gases and the length of time required for aeration. This study evaluated the in vitro use of cold air plasma as an efficient alternative to traditional methods of biodecontamination of hospital surfaces. Cultures of methicillin-resistant Staphylococcus aureus (MRSA), vancomycin-resistant enterococci (VRE), extended-spectrum-β-lactamase (ESBL)-producing Escherichia coli, and Acinetobacter baumannii were applied to different materials similar to those found in the hospital environment. Artificially contaminated sections of marmoleum, mattress, polypropylene, powder-coated mild steel, and stainless steel were then exposed to a cold air pressure plasma single jet for 30 s, 60 s, and 90 s, operating at approximately 25 W and 12 liters/min flow rate. Direct plasma exposure successfully reduced the bacterial load by log 3 for MRSA, log 2.7 for VRE, log 2 for ESBL-producing E. coli, and log 1.7 for A. baumannii. The present report confirms the efficient antibacterial activity of a cold air plasma single-jet plume on nosocomial bacterially contaminated surfaces over a short period of time and highlights its potential for routine biodecontamination in the clinical environment.

  10. Applications of Cold Cathode PIG Ion Source in Lithography

    Bassal, N.I.

    2012-01-01

    The cold cathode Penning ion source (PIG) of axial type could be modified to produce ion and electron beam with a considerable amount to use it in the lithography process. Lithography is a new applications of ion/electron beam at which one can use the ion/ or electron beam as a pencil to write and draw on a metal surface. The electron beam takes 1/3 the time needed for ion beam to make good picture. So that with the help of ion/or electron beam lithography one can mark tools, parts, instruments, and equipment with names, numbers, designs, trademark or brand name in few seconds. It is an easy process, quick and an inexpensive method. Firstly, operating characteristics of this ion source is studied. Lithography application of ion source with optimum conditions is done. Later, the hardness and the tensile strength is measured and each of them increases with increasing time

  11. Exercise in cold air and hydrogen peroxide release in exhaled breath condensate.

    Marek, E; Volke, J; Mückenhoff, K; Platen, P; Marek, W

    2013-01-01

    Athletes have changes in the lung epithelial cells caused by inhalation of cold and dry air. The exhaled breath condensate contains a number of mediators from the respiratory system and H(2)O(2) is described as a marker of airways inflammation. The aim of this study was to determine the influence of exercise combined with cold air on the H(2)O(2) release in the exhaled breath. Twelve males (23.1 ± 1.5 years) were randomly assigned at 2 different days (1 day rest) to perform a 50 min run (75-80% of their max. heart rate) under normal (N) laboratory (18.1 ± 1.1°C) or cold (C) field condition (-15.2 ± 3.1°C). Before and immediately after each run, the EBC was collected under laboratory conditions and was analyzed amperometrically. Prior to the two runs, H(2)O(2) concentrations were 145.0 ± 31.0 (N) and 160.0 ± 49.1 nmol/L (C) and theoretical release was 70.3 ± 37.1 (N) and 82.6 ± 27.1 pmol/min (C) (p > 0.05). After each run, H(2)O(2) concentration increased significantly to 388.0 ± 22.8 nmol/L (N) and 622.1 ± 44.2 nmol/L (C) (p release: 249.2 ± 35.7 pmol/min (N) and 400.9 ± 35.7 pmol/min (C) (p release of H(2)O(2) into the EBC takes place under both resting conditions and after exercise. The concentration and release of H(2)O(2) increased after exercise in cold air compared to resting and laboratory conditions, which points to an increase in inflammatory and oxidative stress.

  12. Modelling of Argon Cold Atmospheric Plasmas for Biomedical Applications

    Atanasova, M.; Benova, E.; Degrez, G.; van der Mullen, J. A. M.

    2018-02-01

    Plasmas for biomedical applications are one of the newest fields of plasma utilization. Especially high is the interest toward plasma usage in medicine. Promising results are achieved in blood coagulation, wound healing, treatment of some forms of cancer, diabetic complications, etc. However, the investigations of the biomedical applications from biological and medical viewpoint are much more advanced than the studies on the dynamics of the plasma. In this work we aim to address some specific challenges in the field of plasma modelling, arising from biomedical applications - what are the plasma reactive species’ and electrical fields’ spatial distributions as well as their production mechanisms; what are the fluxes and energies of the various components of the plasma delivers to the treated surfaces; what is the gas flow pattern? The focus is on two devices, namely the capacitive coupled plasma jet and the microwave surface wave sustained discharge. The devices are representatives of the so called cold atmospheric plasmas (CAPs). These are discharges characterized by low gas temperature - less than 40°C at the point of application - and non-equilibrium chemistry.

  13. Application for approval of the Cold Lake Expansion Project

    1997-02-01

    Imperial Oil Resources Limited applied to the Alberta Energy and Utilities Board for approval to expand its operations at Cold Lake, Alberta and to construct and operate an electrical power plant and electrical generator substation. Imperial Oil also applied to the Alberta Environmental Protection Branch to prepare the site for a new central plant for the expansion. The company also requested a short-term groundwater withdrawal permit to provide temporary water supply for start-up. Imperial Oil claims that the project is in the public interests given the project's social, environmental and economic effects. Imperial Oil submitted this 4 volume document in support of their application. The documentation includes a project description, an environmental impact assessment, a biophysical and resource use assessment, a socio-economic assessment, and environmental baseline studies. The project is scheduled for start-up in late 1999 at a total cost of at least $440 million. refs., tabs., figs

  14. Measurement of cytoplasmic Ca2+ concentration in Saccharomyces cerevisiae induced by air cold plasma

    Xiaoyu, DONG

    2018-03-01

    In this study, a novel approach to measure the absolute cytoplasmic Ca2+ concentration ([Ca2+]cyt) using the Ca2+ indicator fluo-3 AM was established. The parameters associated with the probe fluo-3 AM were optimized to accurately determine fluorescence intensity from the Ca2+-bound probe. Using three optimized parameters (final concentration of 6 mM probe, incubation time of 135 min, loading probe before plasma treatment), the maximum fluorescence intensity (F max = 527.8 a.u.) and the minimum fluorescence intensity (F min = 63.8 a.u.) were obtained in a saturated Ca2+ solution or a solution of lacking Ca2+. Correspondingly, the maximum [Ca2+]cyt induced by cold plasma was 1232.5 nM. Therefore, the Ca2+ indicator fluo-3 AM was successfully applied to measure the absolute [Ca2+]cyt in Saccharomyces cerevisiae stimulated by cold plasma at atmospheric air pressure.

  15. Development and application of the european cold chain database as a tool for cold chain management

    Gogou , E.; Katsaros , G.; Derens , E.; Li , L.; Alvarez , G.; Taoukis , P.

    2013-01-01

    2nd IIR International Conference on Sustainability and the Cold Chain, Paris, FRA, 02-/04/2013 - 04/04/2013; International audience; Storage and distribution are the weakest links in the food management. Their effective control is important for their commercial viability, since they often deviate from specifications. FRISBEE (http://frisbee - project.eu) is a Food Refrigeration Innovation for Cold Chain research IP European project. Within FRISBEE a web - based platform (hosted in the link ht...

  16. Influence of Northeast Monsoon cold surges on air quality in Southeast Asia

    Ashfold, M. J.; Latif, M. T.; Samah, A. A.; Mead, M. I.; Harris, N. R. P.

    2017-10-01

    Ozone (O3) is an important ground-level pollutant. O3 levels and emissions of O3 precursors have increased significantly over recent decades in East Asia and export of this O3 eastward across the Pacific Ocean is well documented. Here we show that East Asian O3 is also transported southward to tropical Southeast (SE) Asia during the Northeast Monsoon (NEM) season (defined as November to February), and that this transport pathway is especially strong during 'cold surges'. Our analysis employs reanalysis data and measurements from surface sites in Peninsular Malaysia, both covering 2003-2012, along with trajectory calculations. Using a cold surge index (northerly winds at 925 hPa averaged over 105-110°E, 5°N) to define sub-seasonal strengthening of the NEM winds, we find the largest changes in a region covering much of the Indochinese Peninsula and surrounding seas. Here, the levels of O3 and another key pollutant, carbon monoxide, calculated by the Monitoring Atmospheric Composition and Climate (MACC) Reanalysis are on average elevated by, respectively, >40% (∼15 ppb) and >60% (∼80 ppb) during cold surges. Further, in the broader region of SE Asia local afternoon exceedances of the World Health Organization's air quality guideline for O3 (100 μg m-3, or ∼50 ppb, averaged over 8 h) largely occur during these cold surges. Day-to-day variations in available O3 observations at surface sites on the east coast of Peninsular Malaysia and in corresponding parts of the MACC Reanalysis are similar, and are clearly linked to cold surges. However, observed O3 levels are typically ∼10-20 ppb lower than the MACC Reanalysis. We show that these observations are also subject to influence from local urban pollution. In agreement with past work, we find year-to-year variations in cold surge activity related to the El Nino-Southern Oscillation (ENSO), but this does not appear to be the dominant influence of ENSO on atmospheric composition in this region. Overall, our study

  17. Design and cold-air test of single-stage uncooled turbine with high work output

    Moffitt, T. P.; Szanca, E. M.; Whitney, W. J.; Behning, F. P.

    1980-01-01

    A solid version of a 50.8 cm single stage core turbine designed for high temperature was tested in cold air over a range of speed and pressure ratio. Design equivalent specific work was 76.84 J/g at an engine turbine tip speed of 579.1 m/sec. At design speed and pressure ratio, the total efficiency of the turbine was 88.6 percent, which is 0.6 point lower than the design value of 89.2 percent. The corresponding mass flow was 4.0 percent greater than design.

  18. Črna Jama as a cold air trap cave within Postojna Cave, Slovenia

    Šebela, Stanka; Turk, Janez

    2017-10-01

    Črna Jama is the coldest section of cave within the Postojna Cave System. Mean annual air temperatures at the Črna Jama 2 site are 5.6 °C (2015) and 5.7 °C (2016), and at the Črna Jama 3 site 7.1 °C (2015) and 7.2 (2016), whereas the mean external air temperature was 10.3 °C (2015) and 10.0 °C (2016). In Lepe Jame, the passage most heavily visited by tourists, the mean cave-air temperature is 10.7 °C (2014-2017). Črna Jama exhibits winter and summer temperature regimes. During warm periods (Tcave Tout), ventilation takes place and dense, cold, outside air sinks into Črna Jama because of the favourable cave entrance morphology. Recent Črna Jama air temperature data (2014-2017) indicate a < 0.5 °C higher temperature than that recorded in historical data since 1933. Črna Jama is the most appropriate place within the Postojna Cave System to study long-term climatic changes. There are hardly any tourist visits to the cave, and human impacts on the cave climate are essentially reduced.

  19. Coefficients of resistance to cold-air-drainage winds on a grass-covered slope

    Komoda, H.; Kobayashi, T.; Mori, M.; Kaneko, T.

    2006-01-01

    The cold-air-drainage (CAD) wind is one of the most familiar local winds in Japan. It is driven by the surplus of density, or the deficit of potential temperature produced by radiative cooling in the surface air layer on a slope, and is resisted by the ground surface and the surrounding atmosphere. The coefficients of resistance of the ground surface and the surrounding atmosphere change with the CAD wind speed. The observations made on a grass-covered slope of Mt. Kuju showed that the resistance exerted by the surrounding atmosphere was much larger than that by the ground surface, and the sum of two coefficients of resistance decreased by one order of magnitude when the CAD wind speed exceeded some critical value

  20. Application of laser assisted cold spraying process for metal deposition

    Tlotleng, Monnamme

    2014-02-01

    Full Text Available Laser assisted cold spraying (LACS) process is a hybrid technique that uses laser and cold spray to deposit solid powders on metal substrates. For bonding to occur, the particle velocities must be supersonic which are achieved by entraining...

  1. THE DEPENDENCE OF HEAT CONSUMPTION ON THE DYNAMICS OF EXTERNAL AIR TEMPERATURE DURING COLD SNAP PERIODS

    Rymarov Andrey Georgievich

    2014-09-01

    Full Text Available The dynamics of outdoor temperature variations during the cold period of the year influences the operation of the systems providing the required microclimate in the premises, which may be subject to automation systems that affects the IQ of a building, it is important to note that in the last decade there has been a growth in the participation of intelligent technologies in the formation of a microclimate of buildings. Studying the microclimate quality in terms of energy consumption of the premises and the building considers climate variability and outdoor air pollution, which is connected with the economic aspects of energy efficiency and productivity, and health of workers, as a short-term temperature fall in the premises has harmful consequences. Low outdoor temperatures dry the air in the premises that requires accounting for climate control equipment and, if necessary, the personal account of its work. Excess heat in the premises, including office equipment, corrects the temperature conditions, which reduces the adverse effect of cold snap.

  2. Air barrier systems: Construction applications

    Perrault, J.C

    1989-01-01

    An examination is presented of how ordinary building materials can be used in an innovative manner to design, detail, and construct effective air barrier systems for common types of walls. For residential construction, the air drywall approach uses the interior gypsum board as the main component of the wall air barrier system. Joints between the gypsum board and adjacent materials or assemblies are sealed by gaskets. In commercial construction, two different techniques are employed for using gypsum board as air barrier material: the accessible drywall and non-accessible drywall approaches. The former is similar to the air drywall approach except that high performance sealants are used instead of gaskets. In the latter approach, exterior drywall sheathing is the main component of the air barrier system; joints between boards are taped and joints between boards and other components are sealed using elastomeric membrane strips. For various types of commercial and institutional buildings, metal air barrier systems are widely used and include pre-engineered curtain walls or sheet metal walls. Masonry wall systems are regarded as still the most durable, fireproof, and soundproof wall type available but an effective air barrier system has typically been difficult to implement. Factory-made elastomeric membranes offer the potential to provide airtightness to masonry walls. These membranes are applied on the entire masonry wall surface and are used to make airtight connections with other building components. Two types of product are available: thermofusible and peel-and-stick membranes. 5 figs.

  3. The comparison of cold-water immersion and cold air therapy on maximal cycling performance and recovery markers following strength exercises

    Kane J. Hayter

    2016-03-01

    Full Text Available This study examined the effects of cold-water immersion (CWI and cold air therapy (CAT on maximal cycling performance (i.e. anaerobic power and markers of muscle damage following a strength training session. Twenty endurance-trained but strength-untrained male (n = 10 and female (n = 10 participants were randomised into either: CWI (15 min in 14 °C water to iliac crest or CAT (15 min in 14 °C air immediately following strength training (i.e. 3 sets of leg press, leg extensions and leg curls at 6 repetition maximum, respectively. Creatine kinase, muscle soreness and fatigue, isometric knee extensor and flexor torque and cycling anaerobic power were measured prior to, immediately after and at 24 (T24, 48 (T48 and 72 (T72 h post-strength exercises. No significant differences were found between treatments for any of the measured variables (p > 0.05. However, trends suggested recovery was greater in CWI than CAT for cycling anaerobic power at T24 (10% ± 2%, ES = 0.90, T48 (8% ± 2%, ES = 0.64 and T72 (8% ± 7%, ES = 0.76. The findings suggest the combination of hydrostatic pressure and cold temperature may be favourable for recovery from strength training rather than cold temperature alone.

  4. Evaluating and managing Cold War era historic properties : the cultural significance of U.S. Air Force defensive radar systems.

    Whorton, M.

    1999-01-20

    Aircraft and later missile radar early warning stations played an important role in the Cold War. They are associated with important technological, social, political, and military themes of the Cold War and are worthy of preservation. The scope and scale of these systems make physical preservation impractical, but the U.S. Air Force program of historical evaluation and documentation of these systems will provide valuable information to future generations studying this historic period.

  5. Study of Cycling Air-Cooling System with a Cold Accumulator for Micro Gas-Turbine Installations

    Ochkov, V. F.; Stepanova, T. A.; Katenev, G. M.; Tumanovskii, V. A.; Borisova, P. N.

    2018-05-01

    Using the cycling air-cooling systems of the CTIC type (Combustion Turbine Inlet Cooling) with a cold accumulator in a micro gas-turbine installation (micro-GTI) to preserve its capacity under the seasonal temperature rise of outside air is described. Water ice is used as the body-storage in the accumulators, and ice water (water at 0.5-1.0°C) is used as the body that cools air. The ice water circulates between the accumulator and the air-water heat exchanger. The cold accumulator model with renewable ice resources is considered. The model contains the heat-exchanging tube lattice-evaporator covered with ice. The lattice is cross-flowed with water. The criterion heat exchange equation that describes the process in the cold accumulator under consideration is presented. The calculations of duration of its active operation were performed. The dependence of cold accumulator service life on water circulation rate was evaluated. The adequacy of the design model was confirmed experimentally in the mock-up of the cold accumulator with a refrigerating machine periodically creating a 200 kg ice reserve in the reservoir-storage. The design model makes it possible to determine the weight of ice reserve of the discharged cold accumulator for cooling the cycle air in the operation of a C-30 type micro- GTI produced by the Capstone Company or micro-GTIs of other capacities. Recommendations for increasing the working capacity of cold accumulators of CTIC-systems of a micro-GTI were made.

  6. Cryocooler With Cold Compressor for Deep Space Applications, Phase I

    National Aeronautics and Space Administration — The unique built-in design features of the proposed mini pulse tube cryocooler avoid all thermal expansion issues enabling it to operate within a cold, 150 K...

  7. A Cold Cycle Dilution Refrigerator for Space Applications, Phase I

    National Aeronautics and Space Administration — The cold cycle dilution refrigerator is a continuous refrigerator capable of cooling to temperatures below 100 mK that makes use of a novel thermal magnetic pump....

  8. Mapping air pollution. Application of nuclear techniques

    Parr, R.M.; Stone, S.F.; Zeisler, R.

    1996-01-01

    Nuclear techniques have important applications in the study of air pollution and many of its components. However, it is in the study of airborne particulate matter (APM) that nuclear analytical techniques find many of their most important applications. This article focuses on those applications, and on the work of the IAEA in this important field of study. 2 figs

  9. Experimental Results Obtained with Air Liquide Cold Compression System CERN LHC and SNS Projects

    Delcayre, F; Hamber, F; Hilbert, B; Monneret, E; Toia, J L

    2006-01-01

    Large scale collider facilities will make intensive use of superconducting magnets, operating below 2.0 K. This dictates high‐capacity refrigeration systems operating below 2.0 K. These systems, making use of cryogenic centrifugal compressors in a series arrangement with room temperature screw compressors will be coupled to a refrigerator, providing a certain power at 4.5 K. A first Air Liquide Cold Compression System (CCS) unit was built and delivered to CERN in 2001. Installed at the beginning of 2002, it was commissioned and tested successfully during year 2002. A series of four sets of identical CCS were then tested in 2004. Another set of four cryogenic centrifugal compressors (CCC) has been delivered to Thomas Jefferson National Accelerator Facility (JLAB) for the Spallation Neutron Source (SNS) in 2002. These compressors were tested and commissioned from December 2004 to July 2005. The experimental results obtained with these systems will be presented and discussed: the characteristics of the CCC wil...

  10. Prediction of cold start hydrocarbon emissions of air cooled two wheeler spark ignition engines by simple fuzzy logic simulation

    Samuel Raja Ayyanan

    2014-01-01

    Full Text Available The cold start hydrocarbon emission from the increasing population of two wheelers in countries like India is one of the research issues to be addressed. This work describes the prediction of cold start hydrocarbon emissions from air cooled spark ignition engines through fuzzy logic technique. Hydrocarbon emissions were experimentally measured from test engines of different cubic capacity, at different lubricating oil temperature and at different idling speeds with and without secondary air supply in exhaust. The experimental data were used as input for modeling average hydrocarbon emissions for 180 seconds counted from cold start and warm start of gasoline bike engines. In fuzzy logic simulation, member functions were assigned for input variables (cubic capacity and idling rpm and output variables (average hydrocarbon emission for first 180 seconds at cold start and warm start. The knowledge based rules were adopted from the analyzed experimental data and separate simulations were carried out for predicting hydrocarbon emissions from engines equipped with and without secondary air supply. The simulation yielded the average hydrocarbon emissions of air cooled gasoline engine for a set of given input data with accuracy over 90%.

  11. Airtightness Results of Roof-Only Air Sealing Strategies on 1 ½-Story Homes in Cold Climates

    Ojczyk, C.; Murry, T.; Mosiman, G.

    2014-07-01

    In this second study on solutions to ice dams in 1-1/2 story homes, the NorthernSTAR Building America Partnership team analyzed five test homes located in both cold and very cold climates for air leakage reduction rates following modifications by independent contractors on owner-occupied homes. These homes were chosen for testing as they are common in Minnesota and very difficult to air seal and insulate effectively. Two projects followed a roof-only Exterior Thermal Moisture Management System (ETMMS) process. One project used an interior-only approach to roof air sealing and insulation. The remaining two projects used a deep energy retrofit approach for whole house (foundation wall, above grade wall, roof) air leakage and heat loss reduction. All were asked to provide information regarding project goals, process, and pre and post-blower door test results. Additional air leakage reduction data was provided by several NorthernSTAR industry partners for interior-applied, roof-only modifications on 1-1/2 story homes. The data represents homes in the general market as well as homes that were part of the state of Minnesota weatherization program. A goal was to compare exterior air sealing methods with interior approaches. This pool of data enabled the team to compare air tightness data from over 220 homes using similar air seal methods.

  12. Airtightness Results of Roof-Only Air Sealing Strategies on 1-1/2 Story Homes in Cold Climates

    Ojczyk, C.; Murry, T.; Mosiman, G.

    2014-07-01

    In this second study on solutions to ice dams in 1-1/2 story homes, five test homes located in both cold and very cold climates were analyzed for air leakage reduction rates following modifications by independent contractors on owner-occupied homes. The reason for choosing this house type was they are very common in our area and very difficult to air seal and insulate effectively. Two projects followed a roof-only Exterior Thermal Moisture Management System (ETMMS) process. One project used an interior-only approach to roof air sealing and insulation. The remaining two projects used a deep energy retrofit approach for whole house (foundation wall, above grade wall, roof) air leakage and heat loss reduction. All were asked to provide information regarding project goals, process, and pre and post-blower door test results. Additional air leakage reduction data was provided by several NorthernSTAR Building America industry partners for interior-applied, roof-only modifications on 1-1/2 story homes. The data represents homes in the general market as well as homes that were part of the state of Minnesota weatherization program. A goal was to compare exterior air sealing methods with interior approaches. This pool of data enabled us to compare air tightness data from over 220 homes using similar air seal methods.

  13. Persistent cold air outbreaks over North America in a warming climate

    Gao, Yang; Leung, L Ruby; Lu, Jian; Masato, Giacomo

    2015-01-01

    This study examines future changes of cold air outbreaks (CAOs) using a multi-model ensemble of global climate simulations from the Coupled Model Intercomparison Project Phase 5 and high resolution regional climate simulations. Overall, climate models agree on a dip in CAO duration across North America, but the percentage change is consistently smaller from western Canada to the upper mid-western US with historically more frequent CAO. By decomposing the changes of the probability density function of daily surface temperature into changes due to mean warming and changes in standard deviation (std) and skewness/higher order moments, the contributions of each factor to CAO changes are quantified. Results show that CAO changes can be explained largely by the mean warming, but the decrease in temperature std contributes to about 20% reduction of CAO from Alaska to northeastern US and eastern Canada possibly due to the Arctic amplification and weakening of storm track. A thermodynamical modulation of the skewness called the ‘0 °C mode’ effect is found to operate prominently along the 0 °C isotherm hemispherically and reduce CAO in western and northeastern US with winter snow cover by up to 10%. This effect also produces a manifold increase in CAO events over the Arctic sea ice. An increased frequency in atmospheric blocking also contributes to increases in CAO duration over Alaska and the Arctic region. Regional simulations revealed more contributions of existing snowpack to CAO in the near future over the Rocky Mountain, southwestern US, and Great Lakes areas through surface albedo effects. Overall, the multi-model projections emphasize that cold extremes do not completely disappear in a warming climate. Concomitant with the relatively smaller reduction in CAO events in northwestern US, the top five most extreme CAO events may still occur, and wind chill will continue to have societal impacts in that region. (letter)

  14. Effect of cold compress application on tissue temperature in healthy dogs.

    Millard, Ralph P; Towle-Millard, Heather A; Rankin, David C; Roush, James K

    2013-03-01

    To measure the effect of cold compress application on tissue temperature in healthy dogs. 10 healthy mixed-breed dogs. Dogs were sedated with hydromorphone (0.1 mg/kg, IV) and diazepam (0.25 mg/kg, IV). Three 24-gauge thermocouple needles were inserted to a depth of 0.5 (superficial), 1.0 (middle), and 1.5 (deep) cm into a shaved, lumbar, epaxial region to measure tissue temperature. Cold (-16.8°C) compresses were applied with gravity dependence for periods of 5, 10, and 20 minutes. Tissue temperature was recorded before compress application and at intervals for up to 80 minutes after application. Control data were collected while dogs received identical sedation but with no cold compress. Mean temperature associated with 5 minutes of application at the superficial depth was significantly decreased, compared with control temperatures. Application for 10 and 20 minutes significantly reduced the temperature at all depths, compared with controls and 5 minutes of application. Twenty minutes of application significantly decreased temperature at only the middle depth, compared with 10 minutes of application. With this method of cold treatment, increasing application time from 10 to 20 minutes caused a further significant temperature change at only the middle tissue depth; however, for maximal cooling, the minimum time of application should be 20 minutes. Possible changes in tissue temperature and adverse effects of application > 20 minutes require further evaluation.

  15. Numerical analysis of the efficiency of earth to air heat exchange systems in cold and hot-arid climates

    Fazlikhani, Faezeh; Goudarzi, Hossein; Solgi, Ebrahim

    2017-01-01

    Highlights: • A numerical model is developed to evaluate performance of earth to air heat exchanger. • The cooling/heating potential of earth to air heat exchanger is investigated in hot-dry and cold climates. • The more performance of earth to air heat exchanger in hot-dry climates compared to cold climates. • The high efficiency of earth to air heat exchanger for pre-heating in both hot-dry and cold climates. - Abstract: In order to examine and compare the efficiency of earth to air heat exchanger (EAHE) systems in hot-arid (Yazd) and cold (Hamadan) climates in Iran a steady state model was developed to evaluate the impact of various parameters including inlet air temperatures, pipe lengths and ground temperatures on the cooling and heating potential of EAHEs in both climates. The results demonstrated the ability of the system to not only improve the average temperature and decrease the temperature fluctuation of the outlet air temperature of EAHE, but also to trigger considerable energy saving. It was found that in both climates, the system is highly utilized for pre-heating, and its usage is unfeasible in certain periods throughout the year. In winter, EAHEs have the potential of increasing the air temperature in the range of 0.2–11.2 °C and 0.1–17.2 °C for Yazd and Hamadan, respectively. However, in summer, the system decreases the air temperature for the aforementioned cities in the range of 1.3–11.4 °C and 5.7–11.1 °C, respectively. The system ascertains to be more efficient in the hot-arid climate of Yazd, where it can be used on 294 days of the year, leading to 50.1–63.6% energy saving, when compared to the cold climate of Hamadan, where it can be used on 225 days of the year resulting in a reduction of energy consumption by 24.5–47.9%.

  16. Hanford Site air operating permit application

    NONE

    1995-05-01

    The Clean Air Act Amendments of 1990, which amended the Federal Clean Air Act of 1977, required that the US Environmental Protection Agency develop a national Air Operating Permit Program, which in turn would require each state to develop an Air Operating Permit Program to identify all sources of ``regulated`` pollutants. Regulated pollutants include ``criteria`` pollutants (oxides of nitrogen, sulfur oxides, total suspended particulates, carbon monoxide, particulate matter greater than 10 micron, lead) plus 189 other ``Hazardous`` Air Pollutants. The Hanford Site, owned by the US Government and operated by the US Department of Energy, Richland Operations Office, is located in southcentral Washington State and covers 560 square miles of semi-arid shrub and grasslands located just north of the confluence of the Snake and Yakima Rivers with the Columbia River. This land, with restricted public access, provides a buffer for the smaller areas historically used for the production of nuclear materials, waste storage, and waste disposal. About 6 percent of the land area has been disturbed and is actively used. The Hanford Site Air Operating Permit Application consists of more than 1,100 sources and in excess of 300 emission points. Before January 1995, the maintenance and operations contractor and the environmental restoration contractor for the US Department of Energy completed an air emission inventory on the Hanford Site. The inventory has been entered into a database so that the sources and emission points can be tracked and updated information readily can be retrieved. The Hanford Site Air Operating Permit Application contains information current as of April 19, 1995.

  17. Hanford Site air operating permit application

    1995-05-01

    The Clean Air Act Amendments of 1990, which amended the Federal Clean Air Act of 1977, required that the US Environmental Protection Agency develop a national Air Operating Permit Program, which in turn would require each state to develop an Air Operating Permit Program to identify all sources of ''regulated'' pollutants. Regulated pollutants include ''criteria'' pollutants (oxides of nitrogen, sulfur oxides, total suspended particulates, carbon monoxide, particulate matter greater than 10 micron, lead) plus 189 other ''Hazardous'' Air Pollutants. The Hanford Site, owned by the US Government and operated by the US Department of Energy, Richland Operations Office, is located in southcentral Washington State and covers 560 square miles of semi-arid shrub and grasslands located just north of the confluence of the Snake and Yakima Rivers with the Columbia River. This land, with restricted public access, provides a buffer for the smaller areas historically used for the production of nuclear materials, waste storage, and waste disposal. About 6 percent of the land area has been disturbed and is actively used. The Hanford Site Air Operating Permit Application consists of more than 1,100 sources and in excess of 300 emission points. Before January 1995, the maintenance and operations contractor and the environmental restoration contractor for the US Department of Energy completed an air emission inventory on the Hanford Site. The inventory has been entered into a database so that the sources and emission points can be tracked and updated information readily can be retrieved. The Hanford Site Air Operating Permit Application contains information current as of April 19, 1995

  18. Experimental Results Obtained with Air Liquide Cold Compression System: CERN LHC and SNS Projects

    Delcayre, F.; Courty, J.-C.; Hamber, F.; Hilbert, B.; Monneret, E.; Toia, J.-L.

    2006-04-01

    Large scale collider facilities will make intensive use of superconducting magnets, operating below 2.0 K. This dictates high-capacity refrigeration systems operating below 2.0 K. These systems, making use of cryogenic centrifugal compressors in a series arrangement with room temperature screw compressors will be coupled to a refrigerator, providing a certain power at 4.5 K. A first Air Liquide Cold Compression System (CCS) unit was built and delivered to CERN in 2001. Installed at the beginning of 2002, it was commissioned and tested successfully during year 2002. A series of four sets of identical CCS were then tested in 2004. Another set of four cryogenic centrifugal compressors (CCC) has been delivered to Thomas Jefferson National Accelerator Facility (JLAB) for the Spallation Neutron Source (SNS) in 2002. These compressors were tested and commissioned from December 2004 to July 2005. The experimental results obtained with these systems will be presented and discussed: the characteristics of the CCC will be detailed. The principles of control for the CCC in series will be detailed.

  19. Measurements of temperature fluctuations in the mixing of hot and cold air jets

    Sumner, V.W.

    1977-03-01

    In order to assess the effect of the mixing of 'hot' and 'cold' jets of sodium on structures in the above-core region of the fast reactor, temperature fluctuations have been measured in an experiment consisting of a heated jet of air surrounded by six unheated jets. Temperature spectra obtained from the experiment showed no strong peaks or bands. In considering the effect of thermal cycling of the above-core structures, it is the higher strain values at low frequencies which will be more limiting than the smaller values at high frequencies, due to the nature of strain-lifetime curves. Thus the spectra have been summarised using a low-frequency level and a cut-off frequency at which this level has fallen by an order of magnitude. Attenuation of temperature fluctuations due to the high thermal conductivity of sodium or by boundary layer effects has been considered; however, in the low-frequency, high-energy region of the spectra, little attenuation can be expected. (author)

  20. Variability of cold season surface air temperature over northeastern China and its linkage with large-scale atmospheric circulations

    Zhuang, Yuanhuang; Zhang, Jingyong; Wang, Lin

    2018-05-01

    Cold temperature anomalies and extremes have profound effects on the society, the economy, and the environment of northeastern China (NEC). In this study, we define the cold season as the months from October to April, and investigate the variability of cold season surface air temperature (CSAT) over NEC and its relationships with large-scale atmospheric circulation patterns for the period 1981-2014. The empirical orthogonal function (EOF) analysis shows that the first EOF mode of the CSAT over NEC is characterized by a homogeneous structure that describes 92.2% of the total variance. The regionally averaged CSAT over NEC is closely linked with the Arctic Oscillation ( r = 0.62, 99% confidence level) and also has a statistically significant relation with the Polar/Eurasian pattern in the cold season. The positive phases of the Arctic Oscillation and the Polar/Eurasian pattern tend to result in a positive geopotential height anomaly over NEC and a weakened East Asian winter monsoon, which subsequently increase the CSAT over NEC by enhancing the downward solar radiation, strengthening the subsidence warming and warm air advection. Conversely, the negative phases of these two climate indices result in opposite regional atmospheric circulation anomalies and decrease the CSAT over NEC.

  1. Going Green and Cold: Biosurfactants from Low-Temperature Environments to Biotechnology Applications.

    Perfumo, Amedea; Banat, Ibrahim M; Marchant, Roger

    2018-03-01

    Approximately 80% of the Earth's biosphere is cold, at an average temperature of 5°C, and is populated by a diversity of microorganisms that are a precious source of molecules with high biotechnological potential. Biosurfactants from cold-adapted organisms can interact with multiple physical phases - water, ice, hydrophobic compounds, and gases - at low and freezing temperatures and be used in sustainable (green) and low-energy-impact (cold) products and processes. We review the biodiversity of microbial biosurfactants produced in cold habitats and provide a perspective on the most promising future applications in environmental and industrial technologies. Finally, we encourage exploring the cryosphere for novel types of biosurfactants via both culture screening and functional metagenomics. Copyright © 2017 Elsevier Ltd. All rights reserved.

  2. Keeping the Edge. Air Force Materiel Command Cold War Context (1945-1991). Volume 1: Command Lineage Scientific Achievement and Major Tenant Missions

    2003-08-01

    Cambridge Research Laboratories AFCS Air Force Communications Service AFETR Air Force Eastern Test Range AFFDL Air Force Flight Dynamics Laboratory...Sacramento Air Logistics Center SMAMA Sacramento Air Materiel Area SOM Skidmore, Owings & Merrill SPACERAD Space Radiation Effects SPADATS Space...a unique post-World War II phenomenon that had a lasting effect —addressed here to illustrate some of the subtleties of the earliest Cold War years

  3. Synoptic climatology, and intrahemispheric associations, of cold air mesocyclones in the Australasian sector

    Carleton, Andrew M.; Song, Yudong

    1997-06-01

    Satellite IR images for seven months in 1992 are interpreted for cold air mesoscale cyclones (mesocyclones) occurring in the Australasian sector (˜70°E-150°W) of the Southern Ocean. Time-averaged (monthly, seasonal) distributions of mesocyclogenesis, mesocyclolysis, and tracks of movement, along with statistical summaries of mesocyclone attributes (e.g., cloud vortex size, speeds of movement), are presented and discussed in the context of the larger-scale atmospheric circulation. Maximum frequencies of mesocyclones occurred in the transitional months of April and October 1992, with a secondary peak in July. Statistically significant differences in mesocyclone track length between months appear related dominantly to changes in speed of the background flow, associated with the semiannual oscillation (SAO) of tropospheric pressure/height. The associations of mesocyclone "outbreaks" with composite anomaly fields of pressure and height are identified for three subareas of the Australasian sector suggested by the analysis of mesocyclone spatial patterns. Outbreaks occur in the strong southerly geostrophic airflow located between pressure and height anomalies that are negative (positive) to the eastward (westward). When outbreaks occurred in the New Zealand subarea in 1992, a similarly strong couplet of pressure/height anomalies developed in the southern South America/Antarctic Peninsula sector but not when outbreaks occurred south of Australia. The mesocyclone remote association that is suggested is evaluated by using polar orbiter IR imagery for the southeastern Pacific region. Frequencies of mesocyclones increase (decrease) west of Chile but decrease (increase) through Drake Passage when mesocyclone outbreaks occur near New Zealand (south of Australia). These long distance associations of mesocyclone outbreaks are consistent with the connectivity of the baroclinic waves and might prove useful in the development of techniques to forecast mesocyclones over the

  4. Learning Large Lessons: The Evolving Roles of Ground Power and Air Power in the Post-Cold War Era. Executive Summary

    Johnson, David E

    2007-01-01

    U.S. post-Cold War military operations have witnessed a shift in the relative roles of ground power and air power in war fighting, but the joint war fighting potential of this shift is not being fully realized...

  5. Cold Heat Release Characteristics of Solidified Oil Droplet-Water Solution Latent Heat Emulsion by Air Bubbles

    Inaba, Hideo; Morita, Shin-Ichi

    The present work investigates the cold heat-release characteristics of the solidified oil droplets (tetradecane, C14H30, freezing point 278.9 K)/water solution emulsion as a latent heat-storage material having a low melting point. An air bubbles-emulsion direct-contact heat exchange method is selected for the cold heat-results from the solidified oil droplet-emulsion layer. This type of direct-contact method results in the high thermal efficiency. The diameter of air bubbles in the emulsion increases as compared with that in the pure water. The air bubbles blown from a nozzle show a strong mixing behavior during rising in the emulsion. The temperature effectiveness, the sensible heat release time and the latent heat release time have been measured as experimental parameters. The useful nondimensional emulsion level equations for these parameters have been derived in terms of the nondimensional emalsion level expressed the emulsion layer dimensions, Reynolds number for air flow, Stefan number and heat capacity ratio.

  6. The structure and energetics of midlatitude disturbances accompanying cold-air outbreaks over East Asia

    Lau, N.-C.; Lau, K.-M.

    1984-01-01

    The evolution of extratropical transient waves as they propagate eastward from the Eurasian land mass toward the Pacific during selected cold surge events in the winter Monsoon Experiment (MONEX) is studied. The outstanding cold surge episodes during MONEX are first identified, and the salient synoptic features related to these events are described using composite streamline charts. The structure of rapidly varying disturbances accompanying the cold surges and the associated energetics are examined, and the behavior of those fluctuations over relatively longer time scales is addressed.

  7. Some applications of the Faddeev-Yakubovsky equations to the cold-atom physics

    Carbonell, J.; Deltuva, A.; Lazauskas, R.

    2011-01-01

    We present some recent applications of the Faddeev-Yakubovsky equations in describing atomic bound and scattering problems. We consider the scattering of a charged particle X by atomic hydrogen with special interest in X = p,e ± , systems of cold bosonic molecules and the bound and scattering properties of N=3 and N=4 atomic 4 He multimers. (authors)

  8. Apollo's Warriors: US Air Force Special Operations during the Cold War

    Hass, Michael

    1997-01-01

    .... Attempting to capture the history of USAF special operations from the beginning of the cold war to the end of the Second Indochina War is an exercise in humility the historian's worst nightmare in some respects...

  9. Industrial applications at the new cold neutron radiography and tomography facility of the HMI

    Kardjilov, N.; Hilger, A.; Manke, I.; Strobl, M.; Treimer, W.; Banhart, J.

    2005-01-01

    The new cold neutron radiography and tomography facility at the Hahn-Meitner-Institut Berlin is suited for the investigation of components and materials from different industrial fields. The high-flux measuring position of the facility allows real-time imaging of fast dynamical processes. Cold neutrons interact stronger with the matter compared to thermal neutrons, which leads to a much better radiography contrast. Some examples of different industry applications like investigations on discharging of a Lithium battery or on oil sediments in a vent pipe are presented

  10. Measurements and Modeling of Turbulent Fluxes during Persistent Cold Air Pool Events in Salt Lake Valley, Utah

    Ivey, C. E.; Sun, X.; Holmes, H.

    2017-12-01

    Land surface processes are important in meteorology and climate research since they control the partitioning of surface energy and water exchange at the earth's surface. The surface layer is coupled to the planetary boundary layer (PBL) by surface fluxes, which serve as sinks or sources of energy, moisture, momentum, and atmospheric pollutants. Quantifying the surface heat and momentum fluxes at the land-atmosphere interface, especially for different surface land cover types, is important because they can further influence the atmospheric dynamics, vertical mixing, and transport processes that impact local, regional, and global climate. A cold air pool (CAP) forms when a topographic depression (i.e., valley) fills with cold air, where the air in the stagnant layer is colder than the air aloft. Insufficient surface heating, which is not able to sufficiently erode the temperature inversion that forms during the nighttime stable boundary layer, can lead to the formation of persistent CAPs during wintertime. These persistent CAPs can last for days, or even weeks, and are associated with increased air pollution concentrations. Thus, realistic simulations of the land-atmosphere exchange are meaningful to achieve improved predictions of the accumulation, transport, and dispersion of air pollution concentrations. The focus of this presentation is on observations and modeling results using turbulence data collected in Salt Lake Valley, Utah during the 2010-2011 wintertime Persistent Cold Air Pool Study (PCAPS). Turbulent fluxes and the surface energy balance over seven land use types are quantified. The urban site has an energy balance ratio (EBR) larger than one (1.276). Negative Bowen ratio (-0.070) is found at the cropland site. In addition to turbulence observations, half-hourly WRF simulated net radiation, latent heat, sensible heat, ground heat fluxes during one persistent CAP event are evaluated using the PCAPS observations. The results show that sensible and latent

  11. A Meteorological Supersite for Aviation and Cold Weather Applications

    Gultepe, Ismail; Agelin-Chaab, M.; Komar, J.; Elfstrom, G.; Boudala, F.; Zhou, B.

    2018-05-01

    The goal of this study is to better understand atmospheric boundary layer processes and parameters, and to evaluate physical processes for aviation applications using data from a supersite observing site. Various meteorological sensors, including a weather and environmental unmanned aerial vehicle (WE-UAV), and a fog and snow tower (FSOS) observations are part of the project. The PanAm University of Ontario Institute of Technology (UOIT) Meteorological Supersite (PUMS) observations are being collected from April 2015 to date. The FSOS tower gathers observations related to rain, snow, fog, and visibility, aerosols, solar radiation, and wind and turbulence, as well as surface and sky temperature. The FSOSs are located at three locations at about 450-800 m away from the PUMS supersite. The WE-UAV measurements representing aerosol, wind speed and direction, as well as temperature (T) and relative humidity (RH) are provided during clear weather conditions. Other measurements at the PUMS site include cloud backscattering profiles from CL51 ceilometer, MWR observations of liquid water content (LWC), T, and RH, and Microwave Rain Radar (MRR) reflectivity profile, as well as the present weather type, snow water depth, icing rate, 3D-ultrasonic wind and turbulence, and conventional meteorological observations from compact weather stations, e.g., WXTs. The results based on important weather event studies, representing fog, snow, rain, blowing snow, wind gust, planetary boundary layer (PBL) wind research for UAV, and icing conditions are given. The microphysical parameterizations and analysis processes for each event are provided, but the results should not be generalized for all weather events and be used cautiously. Results suggested that integrated observing systems based on data from a supersite as well as satellite sites can provide better information applicable to aviation meteorology, including PBL weather research, validation of numerical weather model predictions, and

  12. Technology Application of Environmental Friendly Refrigeration (Green Refrigeration) on Cold Storage for Fishery Industry

    Rasta, IM; Susila, IDM; Subagia, IWA

    2018-01-01

    The application of refrigeration technology to postharvest fishery products is an very important. Moreover, Indonesia is a tropical region with relatively high temperatures. Fish storage age can be prolonged with a decrease in temperature. Frozen fish can even be stored for several months. Fish freezing means preparing fish for storage in low-temperature cold storage. The working fluid used in cold storage to cool low-temperature chambers and throw heat into high-temperature environments is refrigerant. So far refrigerant used in cold storage is Hydrochloroflourocarbons (HCFC) that is R-22. Chlor is a gas that causes ODP (Ozone Depleting Potential), while Flour is a gas that causes GWP (Global Warming Potential). Government policy began in 2015 to implement Hydrochloroflourocarbons Phase-Out Management Plan. Hydrocarbon (HC) is an alternative substitute for R-22. HC-22 (propane ≥ 99.5%) has several advantages, among others: environmentally friendly, indicated by a zero ODP value, and GWP = 3 (negligible), thermophysical property and good heat transfer characteristics, vapor phase density Which is low, and good solubility with mineral lubricants. The use of HC-22 in cold storage is less than R-22. From the analysis results obtained, cold storage system using HC-22 has better performance and energy consumption is more efficient than the R-22.

  13. A Novel Application of Thermoelectric Modules in an HVAC System Under Cold Climate Operation

    Okuma, Toru; Radermacher, Reinhard; Hwang, Yunho

    2012-06-01

    A vapor compression cycle (VCC) with integrated thermoelectric (TE) modules to boost the heating capacity of the system in an energy-efficient way, especially for cold climate operation, is suggested in this paper. While a baseline heat pump (HP) cycle absorbs heat from a source through an evaporator, the proposed system utilizes TE modules as an intermediate (or third) stage of an otherwise two-stage vapor compression system with a vapor injection compressor. This increases the overall system efficiency and augments the system capacity through the high coefficient of performance (COP) of the TE for small temperature lift conditions. To demonstrate the concept, a prototype refrigerant-to-solid (TE) heat exchanger, consisting of TE modules and microchannel flat tubes, was designed and fabricated so that the whole system could realize an additional 1 kW of heating capacity compared with the baseline system. The TE heat exchanger was integrated into a residential HP unit that uses R-410A as a refrigerant, and the system was tested in a laboratory under the severe condition of -17.8°C, in order to investigate the capacity improvement and the overall COP. Finally, an application of this technique in an automotive heating, ventilating, and air-conditioning system with HFC134a working fluid has been studied for the purpose of providing supplemental heating for electric vehicles and hybrid electric vehicles by establishing a detailed simulation model of a HP system with the TE heat exchanger. Both the laboratory test and the calculation study show that a VCC with integrated TE modules has both reasonable efficiency and increased heating capacity.

  14. Developing Android Applications with Adobe AIR

    Brossier, Véronique

    2011-01-01

    Put your ActionScript 3 skills to work building mobile apps. This book shows you how to develop native applications for Android-based smartphones and tablets from the ground up, using Adobe AIR. You learn the entire development process hands-on, from coding specific functions to options for getting your app published. Start by building a sample app with step-by-step instructions, using either Flash Professional or Flash Builder. Then learn how to use ActionScript libraries for typical device features, such as the camera and the accelerometer. This book includes ready-to-run example code and

  15. The Characteristics of Cold Air Outbreaks in the Eastern United States and the Influence of Atmospheric Circulation Patterns

    Smith, E. T.

    2017-12-01

    Periods of extreme cold impact the mid-latitudes every winter. Depending on the magnitude and duration of the occurrence, extremely cold periods may be deemed cold air outbreaks (CAOs). Atmospheric teleconnections impact the displacement of polar air, but the relationship between the primary teleconnections and the manifestation of CAOs is not fully understood. A systematic CAO index was developed from 20 surface weather stations based on a set of criteria concerning magnitude, duration, and spatial extent. Statistical analyses of the data were used to determine the overall trends in CAOs. Clusters of sea level pressure (SLP), 100mb, and 10mb geopotential height anomalies were mapped utilizing self-organizing maps (SOMs) to understand the surface, upper-tropospheric Polar Vortex (PV), and stratospheric PV patterns preceding CAOs. The Arctic Oscillation (AO), North Atlantic Oscillation (NAO), and Pacific-North American (PNA) teleconnections were used as variables to explain the magnitude and location of mid-latitude Arctic air displacement. Persistently negative SLP anomalies across the Arctic and North Atlantic were evident 1 - 2 weeks prior to the CAOs throughout the winter. The upper-tropospheric and stratospheric PV were found to be persistently weak/weakening prior to mid-winter CAOs and predominantly strong and off-centered prior to early and late season CAOs. Negative phases of the AO and NAO were favored prior to CAOs, while the PNA favored a near-neutral phase. This method of CAO and synoptic pattern characterization benefits from a continuous pattern representation and provides insight as to how specific teleconnections impact the atmospheric flow in a way that leads to CAOs in the eastern U.S.

  16. Research on frost formation in air source heat pump at cold-moist conditions in central-south China

    Gong, Guangcai; Tang, Jinchen; Lv, Dongyan; Wang, Hongjin

    2013-01-01

    Highlights: ►A dynamic evaporator model is built up. ► The model involves the ratio of the latent heat to sensible heat of wet air. ►A correlation considering d eq is shown below to predict frost accumulation: (M fr v 3 )/(Ψd eq 2 ) =((T a )/(T w ) ) 0.1 ((vτ)/(d eq ) ) 0.7 (l/(d eq ) ) 1.378 X a 1.228 . ►The changing ratio can characterize the early development of system performance. ►The changing ratio can characterize the early development of frost accumulation. -- Abstract: A dynamic evaporator model of air source heat pump (ASHP), considering the ratio of the latent heat to sensible heat of wet air, is presented to analyze the performance of ASHP under frosting. The performance parameters, such as the heating capacity, COP and the outlet temperature of compressor, are simulated with CYCLEPAD. Then a semi-empirical correlation that predicts frost accumulation on the air-side of fin-tube heat exchanger is developed with dimensionless analysis and also modified by a test conducted under cold-moist conditions in winter. In addition, eight influence factors are considered involving the ambient conditions and structures of heat exchanger, whose effects are analyzed as well. Among them, the equivalent diameter of air flow cross-section in fin-tube d eq is especially proposed. Lastly, the relationships between the ratio, the performance parameters and the frost accumulation are discussed in this paper, followed by an evaluation of an optimal defrosting time interval to improve the ASHP’s energy efficiency and operational reliability at cold-moist conditions in central-south China.

  17. Air dehumidification by membrane with cold water for manned spacecraft environmental control

    Shang Yonghong

    2017-01-01

    Full Text Available The traditional condensation dehumidification method requires additional gas-liquid separation and water recovery process in the manned spacecraft humidity control system, which would increase weight and complexity of systems. A new membrane dehumidification with cold water is proposed, which uses water vapor partial pressure difference to promote water vapor transmembrane mass transfer for dehumidification. The permeability of the membrane was measured and the experimental results agree well with the theoretical calculations. Based on the simulation of dehumidification process of cold water-membrane, the influence of module structure and working condition on dehumidification performance was analyzed, which provided reference for the design of membrane module construct. It can be seen from the simulation and experiments that the cold water-membrane dehumidification can effectively reduce the thermal load of the manned spacecraft.

  18. Whole-body cryotherapy (extreme cold air exposure) for preventing and treating muscle soreness after exercise in adults.

    Costello, Joseph T; Baker, Philip R A; Minett, Geoffrey M; Bieuzen, Francois; Stewart, Ian B; Bleakley, Chris

    2015-09-18

    Recovery strategies are often used with the intention of preventing or minimising muscle soreness after exercise. Whole-body cryotherapy, which involves a single or repeated exposure(s) to extremely cold dry air (below -100 °C) in a specialised chamber or cabin for two to four minutes per exposure, is currently being advocated as an effective intervention to reduce muscle soreness after exercise. To assess the effects (benefits and harms) of whole-body cryotherapy (extreme cold air exposure) for preventing and treating muscle soreness after exercise in adults. We searched the Cochrane Bone, Joint and Muscle Trauma Group Specialised Register, the Cochrane Central Register of Controlled Trials, MEDLINE, EMBASE, CINAHL, the British Nursing Index and the Physiotherapy Evidence Database. We also searched the reference lists of articles, trial registers and conference proceedings, handsearched journals and contacted experts.The searches were run in August 2015. We aimed to include randomised and quasi-randomised trials that compared the use of whole-body cryotherapy (WBC) versus a passive or control intervention (rest, no treatment or placebo treatment) or active interventions including cold or contrast water immersion, active recovery and infrared therapy for preventing or treating muscle soreness after exercise in adults. We also aimed to include randomised trials that compared different durations or dosages of WBC. Our prespecified primary outcomes were muscle soreness, subjective recovery (e.g. tiredness, well-being) and adverse effects. Two review authors independently screened search results, selected studies, assessed risk of bias and extracted and cross-checked data. Where appropriate, we pooled results of comparable trials. The random-effects model was used for pooling where there was substantial heterogeneity. We assessed the quality of the evidence using GRADE. Four laboratory-based randomised controlled trials were included. These reported results for 64

  19. Cold working room temperature increased moderate/severe qualitative work stressor risk in Air Traffic Controllers

    Dewi Astuti

    2012-07-01

    Full Text Available Latar belakang: Pemandu lalu lintas udara (PLLU kemungkinan lebih besar terkena stresor kerja kualitatif. Tujuan penelitian untuk mengidentifikasi beberapa faktor yang berkaitan dengan stresor kerja kualitatif moderat (SBKL sedang di antara PLLU di Bandar Udara Internasional Soekarno-Hatta.Metode:  Studi  potong  lintang  dilakukan  pada  bulan  November 2008  dengan  subjek  PLLU  aktif  bekerja minimal  6  bulan. Penelitian  menggunakan  kuesioner  standar  survei  diagnostik stres  dan  kuesioner  stresor rumah tangga. Kuesioner diisi oleh subjek.Hasil: Subjek berumur 27-55 tahun terdiri dari 122 PLLU dengan SBKL sedang/berat dan serta 13 (9,6% PLLU dengan SBKL rendah. Model menunjukkan bahwa mereka yang merasa dibandingkan dengan yang tidak merasa suhu ruangan terlalu dingin mempunyai 11-lipat risiko SBKL sedang/berat [rasio odds suaian (ORa = 10,63: 95% interval kepercayaan (CI = 1,79-65,59]. Dibandingkan dengan subjek tanpa stresor ketaksaan peran, mereka yang mempunyai stresor ketaksaan peran sedang/berat berisiko 8,2-lipat SBKL sedang/berat (ORa = 8,23: 95% CI = 1,13-59,90. Di samping itu, mereka yang mempunyai stresor tanggung jawab sedang/berat mendapatkan dibandingkan dengan tanpa stesor ini 6,6-kali berisiko SBKL sedang/berat (ORa = 6,64: 95% CI = 1.13-38.85, Selanjutntya mereka yang mempunyai dibandingkan dengan yang tanpa stresor pengembangan karir sedang/berat mempunyai 3,7-kali risiko SBKL sedang/berat  (ORa = 3,67: 95% CI = 0.88-15.35; P = 0,075.Kesimpulan: Subjek LLU yang merasa suhu ruangan terlalu dingin, stresor ketaksaan peran, tanggung jawab personal dan pengembangan karir sedang/berat mengalami peningkatan risiko SBKL sedang/berat. (Health Science Indones 2011;2:58-65.AbstractBack ground: Air traffic controllers (ATCs have a high level of responsibility which may lead to qualitative work load stressor (QLWS. This study identified several risk factors related to moderate qualitative

  20. Effects of menthol application on the skin during prolonged immersion in cool and cold water.

    Botonis, P G; Kounalakis, S N; Cherouveim, E D; Koskolou, M D; Geladas, N D

    2018-03-01

    The aim of the study was to compare the effect of skin surface menthol application on rectal temperature (Tre) during prolonged immersion in cool and cold water. We hypothesized that menthol application would lead to a slower Tre decline due to the reduced heat loss as a consequence of the menthol-induced vasoconstriction and that this effect would be attenuated during cold-water immersion. Six male subjects were immersed for 55 minutes in stirred cool (24°C) or cold (14°C) water immediately after attaining a Tre of 38°C by cycling at 60% of maximum heart rate on two occasions: without (ΝM) and with (M) whole-body skin application of menthol cream. Tre, the proximal-distal skin temperature gradient, and oxygen uptake were continuously measured. ANOVA with repeated measures was employed to detect differences among variables. Significance level was set at 0.05. The area under the curve for Tre was calculated and was greater in 24°C M (-1.81 ± 8.22 a.u) compared to 24°C NM (-27.09 ± 19.09 a.u., P = .03, r = .90), 14°C NM (-18.08 ± 10.85 a.u., P = .03, r = .90), and 14°C M (-11.71 ± 12.58 a.u, P = .05, r = .81). In cool water, oxygen uptake and local vasoconstriction were increased (P ≤ .05) by 39 ± 25% and 56 ± 37%, respectively, with menthol compared to ΝM, while no differences were observed in cold water. Menthol application on the skin before prolonged immersion reduces heat loss resulting in a blunted Tre decline. However, such a response is less obvious at 14°C water immersion, possibly because high-threshold cold-sensitive fibers are already maximally recruited and the majority of cold receptors saturated. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  1. Application of Response Surface Methodology (RSM for Optimization of Operating Parameters and Performance Evaluation of Cooling Tower Cold Water Temperature

    Ramkumar RAMAKRISHNAN

    2012-01-01

    Full Text Available The performance of a cooling tower was analyzed with various operating parameters tofind the minimum cold water temperature. In this study, optimization of operating parameters wasinvestigated. An experimental design was carried out based on central composite design (CCD withresponse surface methodology (RSM. This paper presents optimum operating parameters and theminimum cold water temperature using the RSM method. The RSM was used to evaluate the effectsof operating variables and their interaction towards the attainment of their optimum conditions.Based on the analysis, air flow, hot water temperature and packing height were high significanteffect on cold water temperature. The optimum operating parameters were predicted using the RSMmethod and confirmed through experiment.

  2. An analysis of warm pool and cold tongue El Ninos: air-sea coupling processes, global influences, and recent trends

    Hu, Zeng-Zhen; Kumar, Arun; Wang, Wanqiu [NCEP/NWS/NOAA, Climate Prediction Center, Camp Springs, MD (United States); Jha, Bhaskar; Huang, Boyin [NCEP/NWS/NOAA, Climate Prediction Center, Camp Springs, MD (United States); Wyle Information Systems, Camp Springs, MD (United States); Huang, Bohua [George Mason University, Department of Atmospheric, Oceanic, and Earth Sciences, College of Science, Fairfax, VA (United States); Center for Ocean-Land-Atmosphere Studies, Calverton, MD (United States)

    2012-05-15

    The differences in tropical air-sea interactions and global climate connection as well as the hindcast skills for the warm pool (WP) and cold tongue (CT) El Ninos are investigated based on observed, (re)analyzed, and model hindcast data. The robustness of observed global climate connection is established from the model simulations. Lastly, variations of atmosphere and ocean conditions in the recent decades, and their possible connection with the frequency increase of the WP El Nino are discussed. Consistent with previous results, our individual case study and composite results suggest that stronger (weaker) and more eastward extended (westward confined) westerly wind along the equatorial Pacific in early months of a year is associated with active (suppressed) air-sea interaction over the cold tongue/the Intertropical Convergence Zone complex, as well as more (less) intensive oceanic thermocline feedback, favoring the CT (WP) El Nino development. The preceding westerly wind signal and air-sea interaction differences may be responsible for the predication skill difference with higher (lower) overall hindcast skill for the CT (WP) El Nino in the Climate Forecast System of National Centers for Environmental Prediction. Our model experiments show that, in addition to the tropics, the eastern Pacific, North America and North Atlantic are the major regions having robust climate differences between the CT and WP El Ninos. Nevertheless, the climate contrasts seem not robust over the Eurasian continent. Also, the frequency increase of the WP El Nino in the recent decades may not be directly connected with the linear trend of the tropical climate. (orig.)

  3. Biodiesel and Cold Temperature Effects on Speciated Mobile Source Air Toxics from Modern Diesel Trucks

    Speciated volatile organic compounds (VOCs) with a particular focus on mobile source air toxics (MSATs) were measured in diesel exhaust from three heavy-duty trucks equipped with modern aftertreatment technologies. Emissions testing was conducted on a temperature controlled chass...

  4. Biodiesel and Cold Temperature Effect on Speciated Mobile Source Air Toxics from Modern Diesel Trucks

    Speciated volatile organic compounds (VOCs) with a particular focus on mobile source air toxics (MSATs) were measured in diesel exhaust from three heavy-duty trucks equipped with modern aftertreatment technologies. Emissions testing was conducted on a temperature controlled chass...

  5. Air temperature optimisation for humidity-controlled cold storage of the predatory mites Neoseiulus californicus and Phytoseiulus persimilis (Acari: Phytoseiidae).

    Ghazy, Noureldin Abuelfadl; Suzuki, Takeshi; Amano, Hiroshi; Ohyama, Katsumi

    2014-03-01

    Humidity-controlled cold storage, in which the water vapour pressure is saturated, can prolong the survival of the predatory mites Neoseiulus californicus (McGregor) and Phytoseiulus persimilis Athias-Henriot (Acari: Phytoseiidae). However, information on the optimum air temperature for long-term storage by this method is limited. The authors evaluated the survival of mated adult females of N. californicus and P. persimilis at 5.0, 7.5, 10.0 and 12.5 °C under saturated water vapour condition (vapour pressure deficit 0.0 kPa). N. californicus showed a longer survival time than P. persimilis at all the air temperatures. The longest mean survival time of N. californicus was 11 weeks at 7.5 °C, whereas that of P. persimilis was 8 weeks at 5.0 °C. After storage at 7.5 °C for 8 weeks, no negative effect on post-storage oviposition was observed in N. californicus, whereas the oviposition of P. persimilis stored at 5.0 °C for 8 weeks was significantly reduced. The interspecific variation in the response of these predators to low air temperature might be attributed to their natural habitat and energy requirements. These results may be useful for the long-term storage of these predators, which is required for cost-effective biological control. © 2013 Society of Chemical Industry.

  6. Research on Using the Naturally Cold Air and the Snow for Data Center Air-conditioning, and Humidity Control

    Tsuda, Kunikazu; Tano, Shunichi; Ichino, Junko

    To lower power consumption has becomes a worldwide concern. It is also becoming a bigger area in Computer Systems, such as reflected by the growing use of software-as-a-service and cloud computing whose market has increased since 2000, at the same time, the number of data centers that accumulates and manages the computer has increased rapidly. Power consumption at data centers is accounts for a big share of the entire IT power usage, and is still rapidly increasing. This research focuses on the air-conditioning that occupies accounts for the biggest portion of electric power consumption by data centers, and proposes to develop a technique to lower the power consumption by applying the natural cool air and the snow for control temperature and humidity. We verify those effectiveness of this approach by the experiment. Furthermore, we also examine the extent to which energy reduction is possible when a data center is located in Hokkaido.

  7. Bubbling cell death: A hot air balloon released from the nucleus in the cold.

    Chang, Nan-Shan

    2016-06-01

    Cell death emanating from the nucleus is largely unknown. In our recent study, we determined that when temperature is lowered in the surrounding environment, apoptosis stops and bubbling cell death (BCD) occurs. The study concerns the severity of frostbite. When exposed to severe cold and strong ultraviolet (UV) irradiation, people may suffer serious damages to the skin and internal organs. This ultimately leads to limb amputations, organ failure, and death. BCD is defined as "formation of a single bubble from the nucleus per cell and release of this swelling bubble from the cell surface to extracellular space that causes cell death." When cells are subjected to UV irradiation and/or brief cold shock (4℃ for 5 min) and then incubated at room temperature or 4℃ for time-lapse microscopy, each cell releases an enlarging nuclear gas bubble containing nitric oxide. Certain cells may simultaneously eject hundreds or thousands of exosome-like particles. Unlike apoptosis, no phosphatidylserine flip-over, mitochondrial apoptosis, damage to Golgi complex, and chromosomal DNA fragmentation are shown in BCD. When the temperature is increased back at 37℃, bubble formation stops and apoptosis restarts. Mechanistically, proapoptotic WW domain-containing oxidoreductase and p53 block the protective TNF receptor adaptor factor 2 that allows nitric oxide synthase 2 to synthesize nitric oxide and bubble formation. In this mini-review, updated knowledge in cell death and the proposed molecular mechanism for BCD are provided. © 2016 by the Society for Experimental Biology and Medicine.

  8. HVAC--the importance of clean intake section and dry air filter in cold climate.

    Hanssen, S O

    2004-01-01

    HVAC systems, if properly designed, installed, operated and maintained, will improve thermal conditions and air quality indoors. However, the success strongly depends on the design of the system and the quality of the components we use in our HVAC installations. Regrettably, several investigations have revealed that many HVAC installations have a lot of operational and maintenance problems, especially related to moisture, rain and snow entrainment. In short, it seems that too little attention is placed on the design of the intake section, despite the fact that there exists a large number of national and international guidelines and recommendations. This is a serious problem because the air intake is the initial component of the ventilation plant and as such the first line of defense against debris and other outdoor air pollutants. Unfortunately, the design is often an argued compromise between the architect, the civil engineer and the HVAC engineer. In the future, the technical, hygienic and microbiological feature of air intakes must be better ensured in order to avoid the air intake becoming a risk component as regards contamination and indoor air quality. Further, it seems that the magnitude of the problem is not well known, or recognized, by the building designers, engineers and professionals involved in the construction and operation of buildings. This fact needs to be addressed more seriously, because obviously there is a big difference between the idealistic architectonic design, engineering intentions and the real life situation. Several practical recommendations for design and operation of HVAC systems are presented. Following the recommendations will result in less pollution from the HVAC-system and increased indoor environmental quality.

  9. Application study of monthly precipitation forecast in Northeast China based on the cold vortex persistence activity index

    Gang, Liu; Meihui, Qu; Guolin, Feng; Qucheng, Chu; Jing, Cao; Jie, Yang; Ling, Cao; Yao, Feng

    2018-03-01

    This paper introduces three quantitative indicators to conduct research for characterizing Northeast China cold vortex persistence activity: cold vortex persistence, generalized "cold vortex," and cold vortex precipitation. As discussed in the first part of paper, a hindcast is performed by multiple regressions using Northeast China precipitation from 2012 to 2014 combination with the previous winter 144 air-sea system factors. The results show that the mentioned three cold vortex index series can reflect the spatial and temporal distributions of observational precipitation in 2012-2014 and obtain results. The cold vortex factors are then added to the Forecast System on Dynamical and Analogy Skills (FODAS) to carry out dynamic statistical hindcast of precipitation in Northeast China from 2003 to 2012. Based on the characteristics and significance of each index, precipitation hindcast is carried out for Northeast China in May, June, July, August, May-June, and July-August. It turns out that the Northeast Cold Vortex Index Series, as defined in this paper, can make positive corrections to the FODAS forecast system, and most of the index correction results are higher than the system's own correction value. This study provides quantitative index products and supplies a solid technical foundation and support for monthly precipitation forecast in Northeast China.

  10. Reflections of a Technocrat: Managing Defense, Air, and Space Programs during the Cold War

    2006-08-01

    American-Rockwell OV-10 Bronco , which made its maiden flight in 1965. Deployed to Vietnam three years later, the Bronco was adopted by the Air Force as a...to its em- barrassment, the Air Force had to adapt the Navy’s A-1 Skyraider, A-7 Corsair II, F-4 Phantom II, and the Marines’ OV-10 Bronco for...Station in El Segundo, California, the SecAF’s Office of Special Projects (aka NRO Pro- gram A) performed a variety of support functions as well as

  11. Analysis of Direct Outdoor Air Cooling Efficency for Combined Variable Air Volume Air-conditioning System in Stores in Cold Climates of China

    Luo, Zhiwen

    2006-01-01

    Direct outdoor air cooling contributes a lot not only to the improvement of the indoor air quality but also to the energy saving. Its full use will reduce the water chiller’s running time especially in some stores where cooling load keeps much higher and longer than that in other buildings. A novel air-conditioning system named Combined Variable Air Volume system (CVAV), combining a normal AHU with a separate outdoor air supply system, was proposed firstly by the authors. The most attractive ...

  12. Thermodynamic, Environmental and Economic Analyses of Solar Ejector Refrigeration System Application for Cold Storage

    İbrahim ÜÇGÜL

    2009-02-01

    Full Text Available The refrigeration processes have been widely applied for especially in cold storages. In these plants, the systems working with compressed vapour cooling cycles have been used as a classical method. In general, electrical energy is used for compressing in these processes. Although, mainly the electricity itself has no pollution effect on the environment, the fossil fuels that are widely used to produce electricity in the most of the world, affect the nature terribly. In short, these refrigeration plants, because of the source of the electricity pollute the nature indirectly. However, for compression an ejector refrigeration system requires one of the important renewable energy sources with negligible pollution impact on the environment, namely solar energy from a thermal source. Thermodynamical, environmental and economical aspects of the ejector refrigeration system working with solar energy was investigated in this study. As a pilot case, apple cold storage plants widely used in ISPARTA city, which 1/5 th of apple production of TURKEY has been provided from, was chosen. Enviromental and economical advantages of solar ejector refrigeration system application for cold storage dictated by thermodynamic, economic and enviromental analyses in this research.

  13. Theories, Methods and Numerical Technology of Sheet Metal Cold and Hot Forming Analysis, Simulation and Engineering Applications

    Hu, Ping; Liu, Li-zhong; Zhu, Yi-guo

    2013-01-01

    Over the last 15 years, the application of innovative steel concepts in the automotive industry has increased steadily. Numerical simulation technology of hot forming of high-strength steel allows engineers to modify the formability of hot forming steel metals and to optimize die design schemes. Theories, Methods and Numerical Technology of Sheet Metal Cold and Hot Forming focuses on hot and cold forming theories, numerical methods, relative simulation and experiment techniques for high-strength steel forming and die design in the automobile industry. Theories, Methods and Numerical Technology of Sheet Metal Cold and Hot Forming introduces the general theories of cold forming, then expands upon advanced hot forming theories and simulation methods, including: • the forming process, • constitutive equations, • hot boundary constraint treatment, and • hot forming equipment and experiments. Various calculation methods of cold and hot forming, based on the authors’ experience in commercial CAE software f...

  14. Analysis of air-to-water heat pump in cold climate: comparison between experiment and simulation

    Karolis Januševičius

    2015-10-01

    Full Text Available Heat pump systems are promising technologies for current and future buildings and this research presents the performance of air source heat pump (ASHP system. The system was monitored, analysed and simulated using TRNSYS software. The experimental data were used to calibrate the simulation model of ASHP. The specific climate conditions are evaluated in the model. It was noticed for the heating mode that the coefficient of performance (COP varied from 1.98 to 3.05 as the outdoor temperature changed from –7.0 ºC to +5.0 ºC, respectively. TRNSYS simulations were also performed to predict seasonal performance factor of the ASHP for Vilnius city. It was identified that seasonal performance prediction could be approximately 15% lower if frost formation effects are not included to air-water heat pump simulation model.

  15. The use of an air curtain in a cold store; Vrieshuis toegankelijker en veiliger met luchtscherm

    Bruins, K. [Biddle, Kootstertille (Netherlands)

    1998-04-01

    A food distribution centre of a German chain of supermarkets applies an air curtain in one of their distribution centres (Neudietendorf, Erfurt). The door of the distribution centre building can be left open constantly which improves internal transport of the goods (next to dry products also many frozen products). Even more important is that ice forming in the passage is reduced to a minimum and the safety for the workers has improved considerably

  16. Heating, ventilating, and air-conditioning applications

    Anon.

    1991-01-01

    This book covers: Comfort air conditioning and heating of residences: Space HVAC systems; Industrial and special air conditioning and ventilation for nuclear facilities, and for mines; Energy sources, such as Geothermal energy, solar utilization, and energy resources; Building operation and maintenance; energy management, and Thermal storage

  17. Adobe AIR, Bringing Rich Internet Applications to the Desktop

    Valentin Vieriu

    2009-01-01

    Full Text Available Rich Internet Applications are the new trend in software development today. Adobe AIR offers the possibility to create cross-platform desktop applications using popular Web technologies like HTML, JavaScript, Flash and Flex. This article is focused on presenting the advantages that this new environment has to offer for the web development community and how quickly you can develop a desktop application using Adobe AIR.

  18. Adobe AIR, Bringing Rich Internet Applications to the Desktop

    Vieriu, Valentin; Tuican, Catalin

    2009-01-01

    Rich Internet Applications are the new trend in software development today. Adobe AIR offers the possibility to create cross-platform desktop applications using popular Web technologies like HTML, JavaScript, Flash and Flex. This article is focused on presenting the advantages that this new environment has to offer for the web development community and how quickly you can develop a desktop application using Adobe AIR.

  19. Formal Methods Applications in Air Transportation

    Farley, Todd

    2009-01-01

    The U.S. air transportation system is the most productive in the world, moving far more people and goods than any other. It is also the safest system in the world, thanks in part to its venerable air traffic control system. But as demand for air travel continues to grow, the air traffic control system s aging infrastructure and labor-intensive procedures are impinging on its ability to keep pace with demand. And that impinges on the growth of our economy. Air traffic control modernization has long held the promise of a more efficient air transportation system. Part of NASA s current mission is to develop advanced automation and operational concepts that will expand the capacity of our national airspace system while still maintaining its excellent record for safety. It is a challenging mission, as efforts to modernize have, for decades, been hamstrung by the inability to assure safety to the satisfaction of system operators, system regulators, and/or the traveling public. In this talk, we ll provide a brief history of air traffic control, focusing on the tension between efficiency and safety assurance, and the promise of formal methods going forward.

  20. Incorporating cold-air pooling into downscaled climate models increases potential refugia for snow-dependent species within the Sierra Nevada Ecoregion, CA.

    Jennifer A Curtis

    Full Text Available We present a unique water-balance approach for modeling snowpack under historic, current and future climates throughout the Sierra Nevada Ecoregion. Our methodology uses a finer scale (270 m than previous regional studies and incorporates cold-air pooling, an atmospheric process that sustains cooler temperatures in topographic depressions thereby mitigating snowmelt. Our results are intended to support management and conservation of snow-dependent species, which requires characterization of suitable habitat under current and future climates. We use the wolverine (Gulo gulo as an example species and investigate potential habitat based on the depth and extent of spring snowpack within four National Park units with proposed wolverine reintroduction programs. Our estimates of change in spring snowpack conditions under current and future climates are consistent with recent studies that generally predict declining snowpack. However, model development at a finer scale and incorporation of cold-air pooling increased the persistence of April 1st snowpack. More specifically, incorporation of cold-air pooling into future climate projections increased April 1st snowpack by 6.5% when spatially averaged over the study region and the trajectory of declining April 1st snowpack reverses at mid-elevations where snow pack losses are mitigated by topographic shading and cold-air pooling. Under future climates with sustained or increased precipitation, our results indicate a high likelihood for the persistence of late spring snowpack at elevations above approximately 2,800 m and identify potential climate refugia sites for snow-dependent species at mid-elevations, where significant topographic shading and cold-air pooling potential exist.

  1. Crystallization Analysis and Control of Ammonia-Based Air Source Absorption Heat Pump in Cold Regions

    Wei Wu

    2013-01-01

    Full Text Available Energy consumption of heating and domestic hot water is very high and will keep increasing. Air source absorption heat pump (ASAHP was proposed to overcome the problems of low energy efficiency and high air pollution existing in boiler systems, as well as the problem of bad performance under low ambient temperatures for electrical heat pumps. In order to investigate the crystallization possibility of ammonia-salt ASAHP, crystallization margin (evaluated by solution mass concentration at generating temperature ranging from 100 to 150°C, evaporating temperature from −30 to 10°C, and condensing temperature from 30 to 65°C are analyzed. To prevent the NH3–NaSCN solution from crystallizing, ASAHP integrated with pressure booster located between the evaporator and absorber is simulated. Analysis and comparisons show that NH3–NaSCN is easy to crystallize at relatively high generating temperature, low evaporating temperature, and low condensing temperature. But crystallization margin of NH3–LiNO3 can always stay above 5% for most conditions, keeping away from crystallization. Pressure booster can effectively avoid the crystallization problem that will take place in the NH3–NaSCN ASAHP system.

  2. Steganography System with Application to Crypto-Currency Cold Storage and Secure Transfer

    Michael J. Pelosi

    2018-04-01

    Full Text Available In this paper, we introduce and describe a novel approach to adaptive image steganography which is combined with One-Time Pad encryption and demonstrate the software which implements this methodology. Testing using the state-of-the-art steganalysis software tool StegExpose concludes the image hiding is reliably secure and undetectable using reasonably-sized message payloads (≤25% message bits per image pixel; bpp. Payload image file format outputs from the software include PNG, BMP, JP2, JXR, J2K, TIFF, and WEBP. A variety of file output formats is empirically important as most steganalysis programs will only accept PNG, BMP, and possibly JPG, as the file inputs. In this extended reprint, we introduce additional application and discussion regarding cold storage of crypto-currency account and password information, as well as applications for secure transfer in hostile or insecure network circumstances.

  3. Application of Mastic Asphalt Waterproofing Layer in High-Speed Railway Track in Cold Regions

    Song Liu

    2018-04-01

    Full Text Available Freeze-thaw damage is a typical distress incurred in road and railway engineering in cold regions. Concrete waterproofing layer is commonly used in high-speed railway tracks to prevent the penetration of surface water, however, it cracks easily under thermal stress, especially in cold regions. Recently solutions have been proposed to increase the waterproofing layer’s cracking resistance by using asphalt layers. Nonetheless, the use of emulsified asphalt as well as dense-graded asphalt mixture were not effective enough. To improve the effectiveness, in this study, mastic asphalt was designed for application as the waterproofing layer on the subgrade surface of high-speed railway tracks in cold regions. The overall performance of mastic asphalt was preliminarily evaluated by laboratory tests, then a 200-m test section was constructed for field validation in northeastern China as part of a new high-speed railway line, and water content sensors were placed inside the subgrade to monitor the performance of the mastic asphalt waterproofing layer (MAWL. The subsequent field investigation and monitoring data during the two years operation showed that MAWL dramatically outperformed the conventional concrete waterproofing layer in terms of waterproof performance. Plenty of serious cracks were found in the conventional concrete waterproofing layer, but only a limited number of local cracks were observed in MAWL. As a result, MAWL keeps the water content of subgrade at a stable level. In addition, MAWL showed relatively high stability during the two years investigation period, and no obvious deterioration was observed in the test section.

  4. Air-sea heat flux control on the Yellow Sea Cold Water Mass intensity and implications for its prediction

    Zhu, Junying; Shi, Jie; Guo, Xinyu; Gao, Huiwang; Yao, Xiaohong

    2018-01-01

    The Yellow Sea Cold Water Mass (YSCWM), which occurs during summer in the central Yellow Sea, plays an important role in the hydrodynamic field, nutrient cycle and biological species. Based on water temperature observations during the summer from 1978 to 1998 in the western Yellow Sea, five specific YSCWM years were identified, including two strong years (1984 and 1985), two weak years (1989 and 1995) and one normal year (1992). Using a three-dimensional hydrodynamic model, the YSCWM formation processes in these five years were simulated and compared with observations. In general, the YSCWM began forming in spring, matured in summer and gradually disappeared in autumn of every year. The 8 °C isotherm was used to indicate the YSCWM boundary. The modelled YSCWM areas in the two strong years were approximately two times larger than those in the two weak years. Based on the simulations in the weak year of 1995, ten numerical experiments were performed to quantify the key factors influencing the YSCWM intensity by changing the initial water condition in the previous autumn, air-sea heat flux, wind, evaporation, precipitation and sea level pressure to those in the strong year of 1984, respectively. The results showed that the air-sea heat flux was the dominant factor influencing the YSCWM intensity, which contributed about 80% of the differences of the YSCWM average water temperature at a depth of 50 m. In addition, the air-sea heat flux in the previous winter had a determining effect, contributing more than 50% of the differences between the strong and weak YSCWM years. Finally, a simple formula for predicting the YSCWM intensity was established by using the key influencing factors, i.e., the sea surface temperature before the cooling season and the air-sea heat flux during the cooling season from the previous December to the current February. With this formula, instead of a complicated numerical model, we were able to roughly predict the YSCWM intensity for the

  5. The application of sheet filters in treatment of fruit brandy after cold stabilization

    Miljić Uroš D.

    2013-01-01

    Full Text Available Considering the common use of sheet filtration for clarification of fruit brandies, the aim of this study was to evaluate the influence of its application on the stability and composition of volatile compounds of apricot brandy after cold stabilisation. Cold stabilisation treatment involved holding of the brandy at -1°C during 24 hours. Five depth filter sheets with the nominal retention rate of 0.3 μm, 0.5-0.7 μm, 0.7-1.0 μm, 1.0-2.0 μm and 2.5-4.0 μm, were tested in the study. It was shown that all assessed filter sheets were efficient in removing chill haze by significantly reducing the content of fatty acid esters (primarily ethyl palmitate and ethyl laurate. Other volatile and aromatic compounds were not significantly influenced by the applied treatments. However, the filter sheets with higher nominal retention rate (> 0.7 μm, had a smaller impact on the sensory characteristics of the apricot brandy. The re-exposure to lower temperatures did not lead to chill haze formation in any sample obtained after sheet filtration. [Projekat Ministarstva nauke Republike Srbije, br. TR-31002

  6. Cold Start Emissions of Spark-Ignition Engines at Low Ambient Temperatures as an Air Quality Risk

    Bielaczyc Piotr

    2014-12-01

    Full Text Available SI engines are highly susceptible to excess emissions when started at low ambient temperatures. This phenomenon has multiple air quality and climate forcing implications. Direct injection petrol engines feature a markedly different fuelling strategy, and so their emissions behaviour is somewhat different from indirect injection petrol engines. The excess emissions of direct injection engines at low ambient temperatures should also differ. Additionally, the direct injection fuel delivery process leads to the formation of PM, and DISI engines should show greater PM emissions at low ambient temperatures. This study reports on laboratory experiments quantifying excess emissions of gaseous and solid pollutants over a legislative driving cycle following cold start at a low ambient temperature for both engine types. Over the legislative cycle for testing at -7°C (the UDC, emissions of HC, CO, NOx and CO2 were higher when tested at -7°C than at 24°C. Massive increases in emissions of HC and CO were observed, together with more modest increases in NOx and CO2 emissions. Results from the entire driving cycle showed excess emissions in both phases (though they were much larger for the UDC. The DISI vehicle showed lower increases in fuel consumption than the port injected vehicles, but greater increases in emission of HC and CO. DISI particle number emissions increased by around 50%; DISI particle mass by over 600%. The observed emissions deteriorations varied somewhat by engine type and from vehicle to vehicle. Excesses were greatest following start-up, but persisted, even after several hundred seconds’ driving. The temperature of the intake air appeared to have a limited but significant effect on emissions after the engine has been running for some time. All vehicles tested here comfortably met the relevant EU limits, providing further evidence that these limits are no longer challenging and need updating.

  7. Application of the CPE-air conditioner

    Van Hest, J.; Van der Neut, R.P.; Wijnstra, K.P.

    1986-09-01

    Described is an air conditioning system with a special cooling unit, CPE (combined dew point and heat exchanger). The system has been installed for the first time in the Netherlands in a shop in Utrecht. Results of measurements during September 1985 are presented. 7 figs.

  8. A comparison of ground and satellite observations of cloud cover to saturation pressure differences during a cold air outbreak

    Alliss, R.J.; Raman, S. [North Carolina State Univ., Raleigh, NC (United States)

    1996-04-01

    The role of clouds in the atmospheric general circulation and the global climate is twofold. First, clouds owe their origin to large-scale dynamical forcing, radiative cooling in the atmosphere, and turbulent transfer at the surface. In addition, they provide one of the most important mechanisms for the vertical redistribution of momentum and sensible and latent heat for the large scale, and they influence the coupling between the atmosphere and the surface as well as the radiative and dynamical-hydrological balance. In existing diagnostic cloudiness parameterization schemes, relative humidity is the most frequently used variable for estimating total cloud amount or stratiform cloud amount. However, the prediction of relative humidity in general circulation models (GCMs) is usually poor. Even for the most comprehensive GCMs, the predicted relative humidity may deviate greatly from that observed, as far as the frequency distribution of relative humidity is concerned. Recently, there has been an increased effort to improve the representation of clouds and cloud-radiation feedback in GCMs, but the verification of cloudiness parameterization schemes remains a severe problem because of the lack of observational data sets. In this study, saturation pressure differences (as opposed to relative humidity) and satellite-derived cloud heights and amounts are compared with ground determinations of cloud cover over the Gulf Stream Locale (GSL) during a cold air outbreak.

  9. Warm and Humid Air Blowing over Cold Water - Grand Banks Fog

    Taylor, P.; Weng, W.

    2016-12-01

    The condensation of water vapour into droplets and the formation of fog in the Earth's atmospheric boundary layer involves a complex balance between horizontal advection and vertical turbulent mixing of heat and water vapour, cloud microphysical processes and radiative transfers of heat, plus the impact of water droplets, and sometimes ice crystals, on visibility. It is a phenomenon which has been studied for many years in a variety of contexts. On land, surface cooling of the ground via long wave radiation at night is often the trigger and a number of 1-D (height and time dependent) radiative fog models have been developed. Over the waters offshore from Newfoundland a key factor is the advection of moist air from over warm gulf stream waters to colder Labrador current water - an internal boundary-layer problem. Some basic properties can be learned from a steady state 2-D (x-z) model.The WTS (Weng, Taylor and Salmon, 2010, J. Wind Eng. Ind. Aerodyn. 98, 121-132 ) model of flow above changes in surface conditions has been used to investigate planetary boundary-layer flow over water with spatial changes in temperature, and to investigate situations leading to saturation and fog formation. Our turbulence closure includes the turbulent kinetic energy equation but we prefer to specify a height, surface roughness, Rossby number and local stability dependent, "master" length scale instead of a somewhat empirical dissipation or similar equation. Results show that fog can develop and extent to heights of order 100m in some conditions, depending on upstream profiles of wind, temperature and mixing ratio, and on solar radiation and the horizontal variations in water surface temperature.Next steps will involve validation against data being collected (by AMEC-Foster Wheeler in the Hibernia Management and Development Company Metocean project) over the Grand Banks and an interface with WRF and high resolution sea surface temperature data for forecasting fog conditions over the

  10. Surface Flux Modeling for Air Quality Applications

    Limei Ran

    2011-08-01

    Full Text Available For many gasses and aerosols, dry deposition is an important sink of atmospheric mass. Dry deposition fluxes are also important sources of pollutants to terrestrial and aquatic ecosystems. The surface fluxes of some gases, such as ammonia, mercury, and certain volatile organic compounds, can be upward into the air as well as downward to the surface and therefore should be modeled as bi-directional fluxes. Model parameterizations of dry deposition in air quality models have been represented by simple electrical resistance analogs for almost 30 years. Uncertainties in surface flux modeling in global to mesoscale models are being slowly reduced as more field measurements provide constraints on parameterizations. However, at the same time, more chemical species are being added to surface flux models as air quality models are expanded to include more complex chemistry and are being applied to a wider array of environmental issues. Since surface flux measurements of many of these chemicals are still lacking, resistances are usually parameterized using simple scaling by water or lipid solubility and reactivity. Advances in recent years have included bi-directional flux algorithms that require a shift from pre-computation of deposition velocities to fully integrated surface flux calculations within air quality models. Improved modeling of the stomatal component of chemical surface fluxes has resulted from improved evapotranspiration modeling in land surface models and closer integration between meteorology and air quality models. Satellite-derived land use characterization and vegetation products and indices are improving model representation of spatial and temporal variations in surface flux processes. This review describes the current state of chemical dry deposition modeling, recent progress in bi-directional flux modeling, synergistic model development research with field measurements, and coupling with meteorological land surface models.

  11. Application of argon atmospheric cold plasma for indium tin oxide (ITO) based diodes

    Akbari Nia, S.; Jalili, Y. Seyed; Salar Elahi, A.

    2017-09-01

    Transparent Conductive Oxide (TCO) layers due to transparency, high conductivity and hole injection capability have attracted a lot of attention. One of these layers is Indium Tin Oxide (ITO). ITO due to low resistance, transparency in the visible spectrum and its proper work function is widely used in the manufacture of organic light emitting diodes and solar cells. One way for improving the ITO surface is plasma treatment. In this paper, changes in surface morphology, by applying argon atmospheric pressure cold plasma, was studied through Atomic Force Microscopic (AFM) image analysis and Fourier Transform Infrared Spectroscopy (FTIR) analysis. FTIR analysis showed functional groups were not added or removed, but chemical bond angle and bonds strength on the surface were changed and also AFM images showed that surface roughness was increased. These factors lead to the production of diodes with enhanced Ohmic contact and injection mechanism which are more appropriate in industrial applications.

  12. Structural consideration for hot and cold pipe clamps in LMFBR applications

    Anderson, M.J.; Huang, S.N.; Kappauf, H.; Wagner, S.E.; Wirtz, K.H.

    1983-01-01

    A series of analytical studies are described which evaluate stress levels induced in a 600 mm high temperature, thin-wall sodium pipeline by two alternate clamp designs. The first design consists of a band mounted directly on the pipe and is called the hot clamp. The second design consists of a band mounted using insulation standoffs and is called the cold clamp. Pipe stress levels induced by transient thermal dead weight and seismic loads are discussed. Pipe stress levels and system dynamic spring rates are presented. Procedures utilized to combine clamp induced pipe stress with other short and long term pipe system stresses are detailed. Recommendations for practical application in LMFBR pipe systems are made

  13. Structural considerations for hot and cold pipe clamps in LMFBR applications

    Anderson, M.J.; Huang, S.N.; Wagner, S.E.; Kappauf, H.; Wirtz, K.H.

    1983-01-01

    A series of analytical studies are described which evaluate stress levels induced in a 600 mm high temperature, thin-wall sodium pipeline by two alternate clamp designs. The first design consists of a band mounted directly on the pipe and is called the hot clamp. The second design consists of a band mounted using insulation standoffs and is called the cold clamp. Pipe stress levels induced by transient thermal dead weight and seismic loads are discussed. Pipe stress levels and system dynamic spring rates are presented. Procedures utilized to combine clamp induced pipe stress with other short and long term pipe system stresses are detailed. Recommendations for practical application in LMFBR pipe systems are made

  14. Parametric Study of an Air Charged Franchot Engine with Novel Hot and Cold Isothermalizers

    Jafar M. Daoud

    2017-12-01

    Full Text Available The Stirling engine is an external combustion engine that uses heat exchangers to enhance the addition and removal of energy. This makes the engine power-dense but expensive, less efficient and complicated. In this contribution, the Stirling engine based on the Franchot engine has novel cylindrical fins working as isothermalizers to improve heat transfer without the complications of heat exchangers. Enhancing the power density by isothermalizing work spaces is compared to the bare cylinder optimized by varying the phase angle. The theoretical analysis shows that both the adiabatic and isothermal fins increase the power and efficiency, achieving the Curzon and Ahlborn efficiency at the maximum power point. In comparison to the phase angle method, the finned engine resulted in much lower gas mass flow rate, which leads to a reduction in the regenerator pumping and enthalpy losses. Thus, the Stirling engine has the potential to be simple, cheap, efficient and power-dense, and thus can be used effectively for different applications.

  15. Heat pipe applications for future Air Force spacecraft

    Mahefkey, T.; Barthelemy, R.R.

    1980-01-01

    This paper summarizes the envisioned, future usage of high and low temperature heat pipes in advanced Air Force spacecraft. Thermal control requirements for a variety of communications, surveillance, and space defense missions are forecast. Thermal design constraints implied by survivability to potential weapons effects are outlined. Applications of heat pipes to meet potential low and high power spacecraft mission requirements and envisioned design constraints are suggested. A brief summary of past Air Force sponsored heat pipe development efforts is presented and directions for future development outlined, including those applicable to advanced photovoltaic and nuclear power subsystem applications of heat pipes

  16. Cold sprayed WO3 and TiO2 electrodes for photoelectrochemical water and methanol oxidation in renewable energy applications.

    Haisch, Christoph; Schneider, Jenny; Fleisch, Manuel; Gutzmann, Henning; Klassen, Thomas; Bahnemann, Detlef W

    2017-10-03

    Films prepared by cold spray have potential applications as photoanodes in electrochemical water splitting and waste water purification. In the present study cold sprayed photoelectrodes produced with WO 3 (active under visible light illumination) and TiO 2 (active under UV illumination) on titanium metal substrates were investigated as photoanodes for the oxidation of water and methanol, respectively. Methanol was chosen as organic model pollutant in acidic electrolytes. Main advantages of the cold sprayed photoelectrodes are the improved metal-semiconductor junctions and the superior mechanical stability. Additionally, the cold spray method can be utilized as a large-scale electrode fabrication technique for photoelectrochemical applications. Incident photon to current efficiencies reveal that cold sprayed TiO 2 /WO 3 photoanodes exhibit the best photoelectrochemical properties with regard to the water and methanol oxidation reactions in comparison with the benchmark photocatalyst Aeroxide TiO 2 P25 due to more efficient harvesting of the total solar light irradiation related to their smaller band gap energies.

  17. A numerical study of the effect of vent flow angle on the heat transfer rate from a cold window with a below-window hot-air vent

    Oosthuizen, P.H. [Queen' s Univ., Kingston, ON (Canada). Dept. of Mechanical and Materials Engineering

    2010-07-01

    This study investigated the effects of the discharge angle on air leaving a hot air vent mounted below a window. The window was represented by a plane isothermal section recessed into a wall and was colder than air in the rest of the room. The vent was placed against the wall and had a uniform discharge velocity. Flow was assumed to be steady. Both laminar and turbulent flows were evaluated using a commercial computational fluid dynamics (CFD) simulation tool. A k-epsilon turbulence model was used to determine turbulent flow calculations. The study determined the Rayleigh number based on window height, the Reynolds number based on the vent discharge velocity, the angle of the vent discharge flow, the Prandtl number, and dimensionless vent discharge temperature differences. The study showed that a relatively thin layer of cold air adjacent to the floor is present at high Rayleigh numbers, where the downward natural convective flow over the window dominates the overall flow. At low Rayleigh numbers, the cold air flows upward towards the ceiling and temperatures in the room are nearly uniform. 47 refs., 11 figs.

  18. Fundamentals of air cleaning technology and its application in cleanrooms

    Xu, Zhonglin

    2014-01-01

    Fundamentals of Air Cleaning Technology and Its Application in Cleanrooms sets up the theoretical framework for cleanrooms. New ideas and methods are presented, which include the characteristic index of cleanrooms, uniform and non-uniform distribution characteristics, the minimum sampling volume, a new concept of outdoor air conditioning and the fundamentals of leakage-preventing layers. Written by an author who can look back on major scientific achievements and 50 years of experience in this field, this book offers a concise and accessible introduction to the fundamentals of air cleaning technology and its application. The work is intended for researchers, college teachers, graduates, designers, technicians and corporate R&D personnel in the field of HVAC and air cleaning technology. Zhonglin Xu is a senior research fellow at China Academy of Building Research.

  19. The "Grey Zone" cold air outbreak global model intercomparison: A cross evaluation using large-eddy simulations

    Tomassini, Lorenzo; Field, Paul R.; Honnert, Rachel; Malardel, Sylvie; McTaggart-Cowan, Ron; Saitou, Kei; Noda, Akira T.; Seifert, Axel

    2017-03-01

    A stratocumulus-to-cumulus transition as observed in a cold air outbreak over the North Atlantic Ocean is compared in global climate and numerical weather prediction models and a large-eddy simulation model as part of the Working Group on Numerical Experimentation "Grey Zone" project. The focus of the project is to investigate to what degree current convection and boundary layer parameterizations behave in a scale-adaptive manner in situations where the model resolution approaches the scale of convection. Global model simulations were performed at a wide range of resolutions, with convective parameterizations turned on and off. The models successfully simulate the transition between the observed boundary layer structures, from a well-mixed stratocumulus to a deeper, partly decoupled cumulus boundary layer. There are indications that surface fluxes are generally underestimated. The amount of both cloud liquid water and cloud ice, and likely precipitation, are under-predicted, suggesting deficiencies in the strength of vertical mixing in shear-dominated boundary layers. But also regulation by precipitation and mixed-phase cloud microphysical processes play an important role in the case. With convection parameterizations switched on, the profiles of atmospheric liquid water and cloud ice are essentially resolution-insensitive. This, however, does not imply that convection parameterizations are scale-aware. Even at the highest resolutions considered here, simulations with convective parameterizations do not converge toward the results of convection-off experiments. Convection and boundary layer parameterizations strongly interact, suggesting the need for a unified treatment of convective and turbulent mixing when addressing scale-adaptivity.

  20. Application of solar energy to air conditioning systems

    Nash, J. M.; Harstad, A. J.

    1976-01-01

    The results of a survey of solar energy system applications of air conditioning are summarized. Techniques discussed are both solar powered (absorption cycle and the heat engine/Rankine cycle) and solar related (heat pump). Brief descriptions of the physical implications of various air conditioning techniques, discussions of status, proposed technological improvements, methods of utilization and simulation models are presented, along with an extensive bibliography of related literature.

  1. Development and application of air quality models at the US ...

    Overview of the development and application of air quality models at the U.S. EPA, particularly focused on the development and application of the Community Multiscale Air Quality (CMAQ) model developed within the Computation Exposure Division (CED) of the National Exposure Research Laboratory (NERL). This presentation will provide a simple overview of air quality model development and application geared toward a non-technical student audience. The National Exposure Research Laboratory (NERL) Computational Exposure Division (CED) develops and evaluates data, decision-support tools, and models to be applied to media-specific or receptor-specific problem areas. CED uses modeling-based approaches to characterize exposures, evaluate fate and transport, and support environmental diagnostics/forensics with input from multiple data sources. It also develops media- and receptor-specific models, process models, and decision support tools for use both within and outside of EPA.

  2. 77 FR 34122 - Application of Sun Air Express, LLC, d/b/a Sun Air International for Commuter Authority

    2012-06-08

    ... DEPARTMENT OF TRANSPORTATION Office of the Secretary [Docket DOT-OST-2011-0169] Application of Sun Air Express, LLC, d/b/a Sun Air International for Commuter Authority AGENCY: Department of... order finding Sun Air Express, LLC d/b/a Sun Air International fit, willing, and able, and awarding it...

  3. Characteristics and applications of small, portable gaseous air pollution monitors.

    McKercher, Grant R; Salmond, Jennifer A; Vanos, Jennifer K

    2017-04-01

    Traditional approaches for measuring air quality based on fixed measurements are inadequate for personal exposure monitoring. To combat this issue, the use of small, portable gas-sensing air pollution monitoring technologies is increasing, with researchers and individuals employing portable and mobile methods to obtain more spatially and temporally representative air pollution data. However, many commercially available options are built for various applications and based on different technologies, assumptions, and limitations. A review of the monitor characteristics of small, gaseous monitors is missing from current scientific literature. A state-of-the-art review of small, portable monitors that measure ambient gaseous outdoor pollutants was developed to address broad trends during the last 5-10 years, and to help future experimenters interested in studying gaseous air pollutants choose monitors appropriate for their application and sampling needs. Trends in small, portable gaseous air pollution monitor uses and technologies were first identified and discussed in a review of literature. Next, searches of online databases were performed for articles containing specific information related to performance, characteristics, and use of such monitors that measure one or more of three criteria gaseous air pollutants: ozone, nitrogen dioxide, and carbon monoxide. All data were summarized into reference tables for comparison between applications, physical features, sensing capabilities, and costs of the devices. Recent portable monitoring trends are strongly related to associated applications and audiences. Fundamental research requires monitors with the best individual performance, and thus the highest cost technology. Monitor networking favors real-time capabilities and moderate cost for greater reproduction. Citizen science and crowdsourcing applications allow for lower-cost components; however important strengths and limitations for each application must be addressed

  4. The fabrication and evaluation of diamond cold cathodes for field emitter display applications

    Fox, N.A.

    1998-08-01

    Semiconducting diamond is a candidate wide-band gap material for applications in vacuum microelectronic devices. Its potential use in components that are operated at high frequencies, handle high powers or are subjected to extremes of temperature and radiation have yet to be commercially realised. The work presented below sets out to determine whether semiconducting diamond is a suitable material for such active electronic devices by examining the most efficient means of initiating electron emission from Chemical Vapour Deposited (CVD), semiconducting diamond. Novel methods are reported for the incorporation of impurity atoms of Nitrogen and Phosphorus into CVD diamond that employ ion-implantation techniques. Demonstration of the efficient incorporation of these impurities to form donor states with low activation energies into polycrystalline diamond would facilitate efficient room temperature operation of pn junctions devices. The effectiveness of boron as a p-type dopant in CVD diamond films has enabled the investigation of potential field emitter structures using different boron concentrations in order to identify their respective conduction mechanisms and to make a comparison of their relative electron emission performance. It has been concluded that efficient electron emission is observed to originate from the interface of n + -p, silicon/diamond heterojunctions that employ thin p-type regions which are less than 5μm thick. The emission current may be controlled by the application of a low voltage forward bias of less than 1 volt. Only the np junction containing 400 ppm of boron in the p-diamond layer demonstrated forward biased electron emission. It is proposed that carrier conduction across the junction interface involves recombination and tunnelling steps between interface trap states. Furthermore it is believed that due to the junction interface being in direct contact with vacuum, within this region of the emitter structure, a surface conduction emission

  5. Cold Stress

    ... Publications and Products Programs Contact NIOSH NIOSH COLD STRESS Recommend on Facebook Tweet Share Compartir Workers who ... cold environments may be at risk of cold stress. Extreme cold weather is a dangerous situation that ...

  6. Letter to the Editor: Applications Air Q Model on Estimate Health Effects Exposure to Air Pollutants

    Gholamreza Goudarzi

    2016-02-01

    Full Text Available Epidemiologic studies in worldwide have measured increases in mortality and morbidity associated with air pollution (1-3. Quantifying the effects of air pollution on the human health in urban area causes an increasingly critical component in policy discussion (4-6. Air Q model was proved to be a valid and reliable tool to predicts health effects related to criteria  pollutants (particulate matter (PM, ozone (O3, nitrogen dioxide (NO2, sulfur dioxide (SO2, and carbon monoxide (CO, determinate  the  potential short term effects of air pollution  and allows the examination of various scenarios in which emission rates of pollutants are varied (7,8. Air Q software provided by the WHO European Centre for Environment and Health (ECEH (9. Air Q model is based on cohort studies and used to estimates of both attributable average reductions in life-span and numbers of mortality and morbidity associated with exposure to air pollution (10,11. Applications

  7. Pulsed cold plasma-induced blood coagulation and its pilot application in stanching bleeding during rat hepatectomy

    Keping, YAN; Qikang, JIN; Chao, ZHENG; Guanlei, DENG; Shengyong, YIN; Zhen, LIU

    2018-04-01

    This paper presents plasma-induced blood coagulation and its pilot application in rat hepatectomy by using a home-made pulsed cold plasma jet. Experiments were conducted on blood coagulation in vitro, the influence of plasma on tissue in vivo, and the pilot application of rat hepatectomy. Experimental results show that the cold plasma can lead to rapid blood coagulation. Compared with the control sample, the plasma-induced agglomerated layer of blood is thicker and denser, and is mostly composed of broken platelets. When the surface of the liver was treated by plasma, the influence of the plasma can penetrate into the liver to a depth of about 500 μm. During the rat hepatectomy, cold plasma was proved to be effective for stanching bleeding on incision. No obvious bleeding was found in the abdominal cavities of all six rats 48 h after the hepatectomy. This implies that cold plasma can be an effective modality to control bleeding during surgical operation.

  8. Applicability of multisyringe chromatography coupled to cold-vapor atomic fluorescence spectrometry for mercury speciation analysis

    Guzmán-Mar, J.L.; Hinojosa-Reyes, L.; Serra, A.M.; Hernández-Ramírez, A.; Cerdà, V.

    2011-01-01

    Graphical abstract: An automatic system, based on the applicability of multisyringe chromatography (MSC) coupled to cold-vapor atomic fluorescence spectrometry (CV/AFS) detection is developed for mercury speciation. Highlights: ► The on-line coupling of MSC to CV/AFS was developed for mercury speciation analysis. ► The speciation of MeHg + , Hg 2+ and EtHg + was achieved on a RP C18 monolithic column. ► The hyphenated system provided higher sample throughput compared to HPLC–CV/AFS. ► The limits of detection for mercury species were comparable or better than those reported by HPLC–CV/AFS. ► The developed method also provided low instrumental and operational costs. - Abstract: In this paper, a novel automatic approach for the speciation of inorganic mercury (Hg 2+ ), methylmercury (MeHg + ) and ethylmercury (EtHg + ) using multisyringe chromatography (MSC) coupled to cold-vapor atomic fluorescence spectrometry (CV/AFS) was developed. For the first time, the separation of mercury species was accomplished on a RP C18 monolithic column using a multi-isocratic elution program. The elution protocol involved the use of 0.005% 2-mercapthoethanol in 240 mM ammonium acetate (pH 6)–acetonitrile (99:1, v/v), followed by 0.005% 2-mercapthoethanol in 240 mM ammonium acetate (pH 6)–acetonitrile (90:10, v/v). The eluted mercury species were then oxidized under post-column UV radiation and reduced using tin(II) chloride in an acidic medium. Subsequently, the generated mercury metal were separated from the reaction mixture and further atomized in the flame atomizer and detected by AFS. Under the optimized experimental conditions, the limits of detection (3σ) were found to be 0.03, 0.11 and 0.09 μg L −1 for MeHg + , Hg 2+ and EtHg + , respectively. The relative standard deviation (RSD, n = 6) of the peak height for 3, 6 and 3 μg L −1 of MeHg + , Hg 2+ and EtHg + (as Hg) ranged from 2.4 to 4.0%. Compared with the conventional HPLC–CV/AFS hyphenated systems

  9. Application of cold thermal energy storage (CTES) for building demand management in hot climates

    Comodi, Gabriele; Carducci, Francesco; Nagarajan, Balamurugan; Romagnoli, Alessandro

    2016-01-01

    Highlights: • A new index, Savings per energy unit, is defined to assess the effectiveness of CTES. • CTES systems were used to perform demand management strategies, removing partial load operations and shaving peak loads. • CTES was used to perform price arbitrage, exploiting the difference between peak and off peak electricity rates in Singapore. • Results showed that it is possible to enhance the efficiency of the whole system, achieving both energy and economic savings. • Depending on the sizing scenario, the pay back periods ranged from a minimum of 8.9 years to a maximum of 16 years. - Abstract: This paper investigates the feasibility of Cold Thermal Energy Storage (CTES) for building demand management applications in hot climate characterized by a cooling season lasting all year long. An existing office building, located in Singapore, serves as case study. The CTES is coupled to the existing cooling systems in order to address the opportunity of improving overall energy efficiency and to perform price arbitrage, exploiting the spread between peak and off-peak energy tariffs. Six different sizes for the CTES are analyzed, addressing different percentage of the daily cooling energy demand. A new index, Savings per energy unit, is defined to assess the effectiveness of CTES. Results indicate that it is possible to enhance the efficiency of the whole cooling system, achieving both energy and economic savings. The payback periods of the different solutions range from a minimum of 8.9 years to a maximum of 16 years. All these aspects make CTES applications a viable option. However, a large amount of space in direct proximity to the building is necessary and, especially in largely urban environment, this is not always available.

  10. Design and Optimization of UWB for Air Coupled GPR Applications

    2014-10-01

    of 1°. 36 Figure 36: Measured (dashed) versus simulation (solid) radiation pattern at 1.9GHz Figure 37: Measured ...Evans, S. "Radio techniques for the measurement of ice thickness." Polar Record 11.73 (1963): 406-410. Federal Communications Commission ( FCC ...directed gain and radiation efficiency. DESIGN AND OPTIMIZATION OF UWB ANTENNA FOR AIR COUPLED GPR APPLICATIONS A

  11. Cold recovery during regasification of LNG part one: Cold utilization far from the regasification facility

    La Rocca, Vincenzo

    2010-01-01

    The paper deals with cold recovery during LNG regasification. The applications analyzed pertain to the use in deep freezing agro food industry and in space air conditioning facilities in commercial sector (Supermarkets and Hypermarkets) of cold recovered from the regasification process. A modular LNG regasification unit is proposed having the regasification capacity of 2 BCM/year of gas and it is based on use of a Power Cycle working with Ethane, this unit allows operation of cold energy transfer, contained in LNG to be regasified, in a range of temperatures suitable for multipurpose use of cold, reducing regasification process irreversibility. Some electric energy is produced by the Power Cycle, but the purpose of the modular unit is to deliver cold suitable for industrial and commercial use in the proper temperature range utilizing Carbon dioxide as secondary fluid to transfer cold from regasification site to far end users. The subject is divided in two papers: this paper deals with facilities delivering cold released during LNG regasification and related pipeline facilities to transfer cold at far end users while the other paper pertains to analysis of end users applications. Results of a detailed thermodynamic and economic analysis demonstrate the suitability of the proposal.

  12. Hypothermic general cold adaptation induced by local cold acclimation.

    Savourey, G; Barnavol, B; Caravel, J P; Feuerstein, C; Bittel, J H

    1996-01-01

    To study relationships between local cold adaptation of the lower limbs and general cold adaptation, eight subjects were submitted both to a cold foot test (CFT, 5 degrees C water immersion, 5 min) and to a whole-body standard cold air test (SCAT, 1 degree C, 2 h, nude at rest) before and after a local cold acclimation (LCA) of the lower limbs effected by repeated cold water immersions. The LCA induced a local cold adaptation confirmed by higher skin temperatures of the lower limbs during CFT and a hypothermic insulative general cold adaptation (decreased rectal temperature and mean skin temperature P adaptation was related to the habituation process confirmed by decreased plasma concentrations of noradrenaline (NA) during LCA (P general cold adaptation was unrelated either to local cold adaptation or to the habituation process, because an increased NA during SCAT after LCA (P syndrome" occurring during LCA.

  13. The effect of self-administered superficial local hot and cold application methods on pain, functional status and quality of life in primary knee osteoarthritis patients.

    Aciksoz, Semra; Akyuz, Aygul; Tunay, Servet

    2017-12-01

    To investigate the effect of the self-administered superficial local hot and cold applications on pain, and the functional status and the quality of life in primary knee osteoarthritis patients. Superficial local hot and cold application is used as a nonpharmacological method for the treatment of knee osteoarthritis. However, various guidelines for the management of knee osteoarthritis have conflicting recommendation for hot and cold therapy. A randomised clinical trial design. The sample consisted of patients (n = 96) who were diagnosed with primary knee osteoarthritis. During the application stage, patients were designated to the hot and cold application groups and administered hot and cold application twice a day for 3 weeks together with standard osteoarthritis treatment. The control group only used standard osteoarthritis treatment. The data were collected with a Descriptive Information Form, a Pain Scale, the WOMAC Osteoarthritis Index, the Nottingham Health Profile (NHP) and a Patient Satisfaction Evaluation Form. Outcome measures included pain intensity, functional status and quality of life. We found decreased primary measurement pain scores and improved functional status scores and quality of life scores after the application programme compared to the pre-application stage in both the hot and cold application groups. Once the application was completed, the pain scores, functional status scores and quality-of-life scores on the second measurements were found to be still statistically lower than the pre-application scores but higher than the first measurement ([p  .05). It was found that both hot and cold application resulted in a mild improvement in pain, functional status and quality of life, but this improvement was not sufficient to create a significant difference between the groups. This study contributes to the literature on hot and cold application methods as self-management strategies for patients with knee osteoarthritis. © 2017 John Wiley

  14. Optimal Control of Hybrid Systems in Air Traffic Applications

    Kamgarpour, Maryam

    Growing concerns over the scalability of air traffic operations, air transportation fuel emissions and prices, as well as the advent of communication and sensing technologies motivate improvements to the air traffic management system. To address such improvements, in this thesis a hybrid dynamical model as an abstraction of the air traffic system is considered. Wind and hazardous weather impacts are included using a stochastic model. This thesis focuses on the design of algorithms for verification and control of hybrid and stochastic dynamical systems and the application of these algorithms to air traffic management problems. In the deterministic setting, a numerically efficient algorithm for optimal control of hybrid systems is proposed based on extensions of classical optimal control techniques. This algorithm is applied to optimize the trajectory of an Airbus 320 aircraft in the presence of wind and storms. In the stochastic setting, the verification problem of reaching a target set while avoiding obstacles (reach-avoid) is formulated as a two-player game to account for external agents' influence on system dynamics. The solution approach is applied to air traffic conflict prediction in the presence of stochastic wind. Due to the uncertainty in forecasts of the hazardous weather, and hence the unsafe regions of airspace for aircraft flight, the reach-avoid framework is extended to account for stochastic target and safe sets. This methodology is used to maximize the probability of the safety of aircraft paths through hazardous weather. Finally, the problem of modeling and optimization of arrival air traffic and runway configuration in dense airspace subject to stochastic weather data is addressed. This problem is formulated as a hybrid optimal control problem and is solved with a hierarchical approach that decouples safety and performance. As illustrated with this problem, the large scale of air traffic operations motivates future work on the efficient

  15. Neutron polarizing Fe-Al supermirror on a Si crystal substrate and its applications for thermal and cold neutrons

    Syromyatnikov, V.G.; Shchebetov, A.F.; Soroko, Z.N.

    1994-01-01

    Experimental data are presented for an Fe-Al neutron polarizing supermirror on a Si crystal substrate with an antireflecting Cd layer. The polarizing efficiency of this supermirror is P≥qslant0.8 for the range of glancing angles θ/λ=0.25-1.7 /nm and P≥qslant0.95 for θ/λ=0.34-1.7 /nm. Some applications of this supermirror for thermal and cold neutrons are considered. ((orig.))

  16. The application of Cold Atmospheric Plasma (CAP) for the sterilisation of spacecraft materials

    Rettberg, Petra; Barczyk, Simon; Morfill, Gregor; Thomas, Hubertus; Satoshi Shimizu, .; Shimizu, Tetsuji; Klaempfl, Tobias

    2012-07-01

    Plasma, oft called the fourth state of matter after solid, liquid and gas, is defined by its ionized state. Ionization can be induced by different means, such as a strong electromagnetic field applied with a microwave generator. The concentration and composition of reactive atoms and molecules produced in Cold Atmospheric Plasma (CAP) depends on the gases used, the gas flow, the power applied, the humidity level etc.. In medicine, low-temperature plasma is already used for the sterilization of surgical instruments, implants and packaging materials as plasma works at the atomic level and is able to reach all surfaces, even the interior of small hollow items like needles. Its ability to sterilise is due to the generation of biologically active bactericidal agents, such as free radicals and UV radiation. In the project PLASMA-DECON (DLR/BMWi support code 50JR1005) a prototype of a device for sterilising spacecraft material and components was built based on the surface micro-discharge (SMD) plasma technology. The produced plasma species are directed into a closed chamber which contains the parts that need to be sterilised. To test the inactivation efficiency of this new device bacterial spores were used as model organisms because in the COSPAR Planetary Protection Policy all bioburden constraints are defined with respect to the number of spores (and other heat-tolerant aerobic microorganisms). Spores from different Bacillus species and strains, i.e. wildtype strains from culture collections and isolates from spacecraft assembly cleanrooms, were dried on three different spacecraft relevant materials and exposed to CAP. The specificity, linearity, precision, and effective range of the device was investigated. From the results obtained it can be concluded that the application of CAP proved to be a suitable method for bioburden reduction / sterilisation in the frame of planetary protection measures and the design of a larger plasma device is planned in the future.

  17. Effects of peripheral cold application on core body temperature and haemodynamic parameters in febrile patients.

    Asgar Pour, Hossein; Yavuz, Meryem

    2014-04-01

    This study designed to assess the effects of peripheral cold application (PCA) on core body temperature and haemodynamic parameters in febrile patients. This study was an experimental, repeated-measures performed in the neurosurgical intensive-care unit. The research sample included all patients with fever in postoperative period. PCA was performed for 20 min. During fever, systolic blood pressure, mean arterial blood pressure and arterial oxygen saturation (O2 Sat) decreased by 5.07 ± 7.89 mm Hg, 0.191 ± 6.00 mm Hg and 0.742% ± 0.97%, respectively, whereas the pulse rate and diastolic blood pressure increased by 8.528 ± 4.42 beats/ min and 1.842 ± 6.9 mmHg, respectively. Immediately after PCA, core body temperature and pulse rate decreased by 0.3°C, 3.3 beats/min, respectively, whereas systolic, diastolic, mean arterial blood pressure and O2 Sat increased by, 1.40 mm Hg, 1.87 mm Hg, 0.98 mmHg and 0.27%, respectively. Thirty minutes after the end of PCA, core body temperature, diastolic, mean arterial blood pressure and pulse rate decreased by 0.57°C, 0.34 mm Hg, 0.60 mm Hg and 4.5 beats/min, respectively, whereas systolic blood pressure and O2 Sat increased by 0.98 mm Hg and 0.04%, respectively. The present results showed that PCA increases systolic, diastolic, mean arterial blood pressure and O2 Sat, and decreases core body temperature and pulse rate. © 2013 Wiley Publishing Asia Pty Ltd.

  18. Cold recovery during regasification of LNG part two: Applications in an Agro Food Industry and a Hypermarket

    La Rocca, Vincenzo

    2011-01-01

    The paper deals with the cold energy available during LNG regasification, which can be recovered and utilized both inside the LNG regasification area and at a distance, such as in deep freezing agro food industry facilities and for space conditioning in the commercial and residential sector (e.g. Supermarkets and Hypermarkets). The feasibility study of this kind of application has been carried out at DREAM, Palermo University, within the framework of a research program. The results of a feasibility study of the kind of venture proposed, starting from its conceptual design and with a thorough thermodynamic and economic analysis, demonstrated the suitability and the profitability of the applications proposed. They seem very attractive due to expected wide future exploitation of LNG regasification in the World. -- Highlights: → Proposal pertaining cold recovery during LNG regasification. → Cold utilization far from the regasification site. → Transfer of liquid/gaseous carbon dioxide pipeline. → Exergetic and economic analysis of venture pertaining applications proposed. → Results of venture economic analysis.

  19. Coating Properties of WC-Ni Cold Spray Coating for the Application in Secondary Piping System of Nuclear Power Plants

    Kim, JeongWon; Kim, Seunghyun; Kim, Ji Hyun [UNIST, Ulsan (Korea, Republic of)

    2015-10-15

    As a result of FAC(flow accelerated corrosion), severe accidents, failure of carbon steel like a Mihama Unit-3 occurred. Chemical composition change of carbon steel or coating to inner surface is one of methods to improve corrosion properties. Among them, thermal spray coating is convenient solution to apply at industry. Powder is melted at blast furnace and ejected to substrate. After adhesion, substrate and coating layer is cooled down and coated layer protects steel from corrosion finally. However high thermal energy is transferred to substrate and coating layer so it leads high thermal residual stress in coating procedure. Besides, high temperature for melting powder makes unexpected chemical reaction of powder like an oxidation or carburization. Whereas, cold spray uses low temperature comparing with other thermal spray. Thermal energy is used for not melting powder but high kinetic energy of powder and plastic deformation during collision. Therefore, fuel such as oxygen-acetylene gas is not needed. It needs carrier gas, compressed air, nitrogen or helium, to increase kinetic energy of powder and move powder to substrate. Comparing cold spray with high velocity oxy fuel (HVOF), one of thermal spray, cold spray coating layer contains only WC and Co. One of other problem about WC is brittleness during coating. To improve deformability of WC, binder metal is added. For example, Co, Cr, Ni, Cu, Al, Fe or etc. Additionally, binder metal lowering melting temperature of composite powder increases coating properties. Among them, Co which is widely used as binder metal maintains mechanical properties like a hardness and improves corrosion properties. Therefore Co is not suitable for binder metal of WC coating. In contrast, Ni has better corrosion resistance to alkaline environment and makes lower melting temperature. Moreover, in a view of cold spray, FCC structure has better deformability than BCC or HCP, and BCC has lowest deformability. WC is BCC structure so it

  20. Aerospace toxicology overview: aerial application and cabin air quality.

    Chaturvedi, Arvind K

    2011-01-01

    Aerospace toxicology is a rather recent development and is closely related to aerospace medicine. Aerospace toxicology can be defined as a field of study designed to address the adverse effects of medications, chemicals, and contaminants on humans who fly within or outside the atmosphere in aviation or on space flights. The environment extending above and beyond the surface of the Earth is referred to as aerospace. The term aviation is frequently used interchangeably with aerospace. The focus of the literature review performed to prepare this paper was on aerospace toxicology-related subject matters, aerial application and aircraft cabin air quality. Among the important topics addressed are the following: · Aerial applications of agricultural chemicals, pesticidal toxicity, and exposures to aerially applied mixtures of chemicals and their associated formulating solvents/surfactants The safety of aerially encountered chemicals and the bioanalytical methods used to monitor exposures to some of them · The presence of fumes and smoke, as well as other contaminants that may generally be present in aircraft/space vehicle cabin air · And importantly, the toxic effects of aerially encountered contaminants, with emphasis on the degradation products of oils, fluids, and lubricants used in aircraft, and finally · Analytical methods used for monitoring human exposure to CO and HCN are addressed in the review, as are the signs and symptoms associated with exposures to these combustion gases. Although many agricultural chemical monitoring studies have been published, few have dealt with the occurrence of such chemicals in aircraft cabin air. However, agricultural chemicals do appear in cabin air; indeed, attempts have been made to establish maximum allowable concentrations for several of the more potentially toxic ones that are found in aircraft cabin air. In this article, I emphasize the need for precautionary measures to be taken to minimize exposures to aerially

  1. Applicability of multisyringe chromatography coupled to cold-vapor atomic fluorescence spectrometry for mercury speciation analysis

    Guzman-Mar, J.L.; Hinojosa-Reyes, L. [Department of Chemistry Sciences, Universidad Autonoma de Nuevo Leon, Cd. Universitaria, Pedro de Alba s/n, C.P. 66451 San Nicolas de los Garza, Nuevo Leon (Mexico); Serra, A.M. [Department of Chemistry, University of the Balearic Islands, E-07122 Palma de Mallorca (Spain); Hernandez-Ramirez, A. [Department of Chemistry Sciences, Universidad Autonoma de Nuevo Leon, Cd. Universitaria, Pedro de Alba s/n, C.P. 66451 San Nicolas de los Garza, Nuevo Leon (Mexico); Cerda, V., E-mail: victor.cerda@uib.es [Department of Chemistry, University of the Balearic Islands, E-07122 Palma de Mallorca (Spain)

    2011-12-05

    Graphical abstract: An automatic system, based on the applicability of multisyringe chromatography (MSC) coupled to cold-vapor atomic fluorescence spectrometry (CV/AFS) detection is developed for mercury speciation. Highlights: Black-Right-Pointing-Pointer The on-line coupling of MSC to CV/AFS was developed for mercury speciation analysis. Black-Right-Pointing-Pointer The speciation of MeHg{sup +}, Hg{sup 2+} and EtHg{sup +} was achieved on a RP C18 monolithic column. Black-Right-Pointing-Pointer The hyphenated system provided higher sample throughput compared to HPLC-CV/AFS. Black-Right-Pointing-Pointer The limits of detection for mercury species were comparable or better than those reported by HPLC-CV/AFS. Black-Right-Pointing-Pointer The developed method also provided low instrumental and operational costs. - Abstract: In this paper, a novel automatic approach for the speciation of inorganic mercury (Hg{sup 2+}), methylmercury (MeHg{sup +}) and ethylmercury (EtHg{sup +}) using multisyringe chromatography (MSC) coupled to cold-vapor atomic fluorescence spectrometry (CV/AFS) was developed. For the first time, the separation of mercury species was accomplished on a RP C18 monolithic column using a multi-isocratic elution program. The elution protocol involved the use of 0.005% 2-mercapthoethanol in 240 mM ammonium acetate (pH 6)-acetonitrile (99:1, v/v), followed by 0.005% 2-mercapthoethanol in 240 mM ammonium acetate (pH 6)-acetonitrile (90:10, v/v). The eluted mercury species were then oxidized under post-column UV radiation and reduced using tin(II) chloride in an acidic medium. Subsequently, the generated mercury metal were separated from the reaction mixture and further atomized in the flame atomizer and detected by AFS. Under the optimized experimental conditions, the limits of detection (3{sigma}) were found to be 0.03, 0.11 and 0.09 {mu}g L{sup -1} for MeHg{sup +}, Hg{sup 2+} and EtHg{sup +}, respectively. The relative standard deviation (RSD, n = 6) of the

  2. The characteristics of welded joints for air conditioning application

    Weglowski, M. St.; Weglowska, A.; Miara, D.; Kwiecinski, K.; Błacha, S.; Dworak, J.; Rykala, J.; Pikula, J.; Ziobro, G.; Szafron, A.; Zimierska-Nowak, P.; Richert, M.; Noga, P.

    2017-10-01

    In the paper the results of metallographic examination of welded joints for air-conditioning elements are presented. The European directives 2006/40/EC on the greenhouse gasses elimination demand to stop using traditional refrigerant and to change it to R744 (CO2) medium in air conditioning installation. The R744 refrigerant is environmental friendly medium if compared with standard solution such as R12, R134a or R1234yf and safer for passengers than R1234yf. The non-standard thermodynamic parameters of the R744 which translate into high pressure and high temperature require specific materials to develop the shape and to specify the technology of manufacturing for the particular elements of the conduits and moreover the technologies of joining for the whole structure, which would meet the exploitation requirements of the new air-conditioning system. To produce the test welded joints of stainless steels four different joining technologies were applied: laser welding, plasma welding, electron beam welding as well as high speed rotation welding. This paper describes the influence of the selected welding process on the macrostructure and microstructure of welded joints of AISI 304 and AISI 316L steels. The results indicated that plasma welding laser welding and electron beam welding technologies guaranty the proper quality of welded joints and can be used for the air conditioning application in automotive industry. However, high speed rotation welding not guarantee the good quality of welded joints and cannot be used for above application.

  3. Clinical application of 201Tl scintigraphy in patients with cold thyroid nodules

    Tonami, N.; Bunko, H.; Michigishi, T.; Kuwajima, A.; Hisada, K.

    1978-01-01

    201 Tl-chloride scintigraphy was performed in 45 patients with cold thyroid nodules. The 201 Tl scintigram was positive in 17 of 18 thyroid patients with cancer (94.4%), 8 of 20 patients with an adenoma (40.0%), 1 of 2 adenomatous goiter patients (50.5%), and all of 5 cases of chronic thyroiditis (100.0%). When the cold nodule was demonstrated to be positive with 201 Tl, the statistical chance of the lesion being a cellular one was 100.0% and a risk of its malignancy was 54.8%. On the other hand, the nodule with negative 201 Tl concentration had a 14.3% chance of cellularity and a 7.1% risk of malignancy. Thus, 201 Tl scintigraphy is of use in the differential diagnosis of the cold thyroid nodule

  4. Application of Herbal Medicines with Bitter Flavor and Cold Property on Treating Diabetes Mellitus

    Hongdong Chen

    2015-01-01

    Full Text Available Diabetes mellitus has been a global pandemic. Traditional Chinese Medicine has been used on diabetes mellitus for thousands of years and the modern Chinese medicine studies have found a curative effect of herbal medicine with bitter flavor and cold property on diabetes. This review will introduce the theory summary of flavor and property in TCM, argument basis, the evidences from clinical trails and animal experiments, the possible antidiabetic mechanisms, and advantages on lowering glucose of herbal medicines with bitter flavor and cold property and take rhizome, Chinese rhubarb, and Momordica charantia, the three herbal medicines with bitter flavor and cold property, as examples to illustrate the exact antidiabetic effect. It is hoped that this review can provide some ideas and inspiration for the treatment of diabetes with herbal medicine.

  5. Measuring the speed of sound in air using smartphone applications

    Yavuz, A.

    2015-05-01

    This study presents a revised version of an old experiment available in many textbooks for measuring the speed of sound in air. A signal-generator application in a smartphone is used to produce the desired sound frequency. Nodes of sound waves in a glass pipe, of which one end is immersed in water, are more easily detected, so results can be obtained more quickly than from traditional acoustic experiments using tuning forks.

  6. The Application Research of Modern Intelligent Cold Chain Distribution System Based on Internet of Things Technology

    Fan, Dehui; Gao, Shan

    This paper implemented an intelligent cold chain distribution system based on the technology of Internet of things, and took the protoplasmic beer logistics transport system as example. It realized the remote real-time monitoring material status, recorded the distribution information, dynamically adjusted the distribution tasks and other functions. At the same time, the system combined the Internet of things technology with weighted filtering algorithm, realized the real-time query of condition curve, emergency alarming, distribution data retrieval, intelligent distribution task arrangement, etc. According to the actual test, it can realize the optimization of inventory structure, and improve the efficiency of cold chain distribution.

  7. Heterogeneous Photocatalysis: Fundamentals and Application for Treatment of Polluted Air

    Tomašić, V.

    2011-07-01

    Full Text Available The use of heterogeneous photocatalysts for the abatement of environmental problems has received increased attention during the last three decades. The photocatalyst used in most of these studies was titanium dioxide. This fact relates to the unique physical and chemical properties of titanium dioxide and similar semiconductor materials, such as ZnO, MgO,WO3, Fe2Oa, CdS, etc. that may be utilized for a wide range of potential applications. Specifically, upon ultraviolet irradiation these materials exhibit photocatalytic activity that enables the oxidative destruction of a wide range of organic compounds and biological species on their surface. In addition, these materials may also exhibit photocatalytically induced superhydrophilicity that converts the hydrophobic character of the surface to hydrophilic when exposed to UV light. This causes the formation of uniform water films on the surface of these materials, which prevents the adhesion of inorganic or organic components and thus retains a clean surface on the photocatalyst. Photocatalytic materials may be deployed on surfaces of various substrates, such as glass, ceramics or metals to provide layers that exhibit photocatalytic activity when they are exposed to light. Excitation of a photocatalyst leads to the creation of electrons and holes in the semiconductor material. Furthermore, these electrons and holes interact with molecules adsorbed on the semiconductor and can induce charge transfer process that results in the degradation of the adsorbate. The commercial potentials of heterogeneous photocatalysis are huge, including medical applications, application in the field of architecture (particularly for the cultural heritage purposes, facade paints, etc., automotive and food industries (cleaner technologies, non-fogging glass and mirrors, product safety, textile and glass industry, as well as in environmental protection (water and air purification and disinfection. After the discovery that

  8. Stratospheric Air Sub-sampler (SAS) and its application to analysis of Delta O-17(CO2) from small air samples collected with an AirCore

    Mrozek, Dorota Janina; van der Veen, Carina; Hofmann, Magdalena E. G.; Chen, Huilin; Kivi, Rigel; Heikkinen, Pauli; Rockmann, Thomas

    2016-01-01

    We present the set-up and a scientific application of the Stratospheric Air Sub-sampler (SAS), a device to collect and to store the vertical profile of air collected with an AirCore (Karion et al., 2010) in numerous sub-samples for later analysis in the laboratory. The SAS described here is a 20m

  9. Challenges in application of Active Cold Loads for microwave radiometer calibration

    Søbjærg, Sten Schmidl; Balling, Jan E.; Skou, Niels

    2012-01-01

    Two Active Cold Loads (ACLs) for microwave radiometer calibration, operating at X-band, are evaluated with respect to important stability parameters. Using a stable radiometer system as test bed, absolute levels of 77 K and 55 K are found. This paper identifies and summarizes potential challenges...

  10. Application of infrared thermography for the analysis of rewarming in patients with cold intolerance

    Ruijs, A.C.J.; Jaquet, J.B.; Brandsma, M.; Daanen, H.A.M.; Hovius, S.E.R.

    2008-01-01

    Cold intolerance is a serious long-term problem after injury to the ulnar and median nerves, and its pathophysiology is unclear. We investigated the use of infrared thermography for the analysis of thermoregulation after injury to peripheral nerves. Four patients with injuries to the ulnar nerve and

  11. Application of Natural Air Drying on Shelled Corn in Timor

    Nino, J.; Nelwan, L. O.; Purwanto, Y. A.

    2018-05-01

    A study of the application of natural air drying on shelled corn in Timor using a bed- type dryer has been performed. The study aspects were limited to obtain the suitable air flow rate requirement and duration of the drying operation per day. For each aspect, the treatments were carried out simultaneously. The results showed that at the average ambient air temperature of 30.6°C and relative humidity (RH) of 73.0% the air flow rate of 0.83 L/s-kg provided the highest drying rate. Subsequently, by using the same air flow rate, three scheme of drying operations duration were used, i.e., 8 hours per day (08.00-16.00), 6 hours per day (09.00-15.00) and 4 hours per day (10.00-14.00). The average temperature and RH of ambient air condition at the second experiment were 30.3°C and 73.3% respectively. After 4 days of drying, the 8 hours per day (first scheme) treatment was able to dry the shelled corn from the initial moisture content of 27.24% w.b. to the final moisture content of 14.05% w.b. The specific energy consumption (SEC) of the first scheme was 1.75 MJ/kg. The final moisture content of the second and third schemes were 15.08 % w.b. and 18.45 % w.b. respectively with SEC of 1.41 MJ/kg and 1.21 MJ/kg respectively.

  12. Potential applications of heat and cold stress indices to sporting events.

    Moran, D S

    2001-01-01

    Many recreational and elite athletes participate in sporting events every year. However, when these events are conducted under hostile environmental conditions, whether in cold or hot climates, the risk for environmental illnesses increases. The higher the stress, the greater is the potential for performance decrements, injuries and illnesses. The most common expected heat illnesses are heat exhaustion and heatstroke, whereas hypothermia and frostbite are the most common cold injuries. However, heat and cold stress indices can minimise the risk for environmental illnesses and dehydration by following the recommendations and guidelines which accompany these indices. Stress indices should be used by athletes, coaches and officials to prevent injury and improve safety conditions for competitors and participants in recreational activities. All participants should be made aware of warning signs, susceptibility and predisposing conditions. Coaches should be aware of their responsibility with regard to the safety of their trainees, and officials should organise and plan events at times that are likely to be of low environmental stress. However, they must also be prepared and equipped with the means necessary to reduce injuries and treat cases of collapse and environmental illnesses. The lack of a friendly, small and simple device for environmental stress assessment is probably the main reason why stress indices are not commonly used. We believe that developing a new portable heat and cold stress monitor in wristwatch format for use by those exposed to environmental stress could help in the decision making process of expected hazards caused by exercising and working in hostile environments, and might help prevent heat and cold illnesses.

  13. EFFECTS OF COMPRESSED AIR FOAM APPLICATION ON HEAT

    Adam THOMITZEK

    2015-12-01

    Full Text Available This article evaluates the knowledge obtained in firefighting tests using compressed air foam system (CAFS within a confined space. Six experiments were conducted for verification during the cooling of rooms and the self-extinguishing effect. The simulation was for a fully developed fire within a room. The fuel was chosen to simulate ordinary combustible materials utilized in residential areas. Mantel thermocouples were placed in the rooms to record the temperature changes. Compressed air foam was first applied with a standard fire hose nozzle to the ceiling and then to the epicenter of fire. Fire extinguishing was initiated after reaching the desired temperature in the room. The temperature for the start of fire extinguishing matched the third phase of development of a fire. Fire extinguishing was terminated after no obvious signs of fire were shown in epicenter of fire. The outputs of the experiments were evaluated on the basis of the amount of time passed for the temperature to drop below the suggested limit. Individual experiments were also conducted with various different admixing foaming agents over different locations. In the experiments, it has been verified that the application of compressed air foam has a positive effect on room cooling. Use of a compressed air foaming agent does not allow for the development of steam that can scald firefighters and reduce visibility. Furthermore, the extinguishing agent used is more efficient utilizing less water flow out of the fire area.

  14. On air-chemistry reduction for hypersonic external flow applications

    Ibrahim, Ashraf; Suman, Sawan; Girimaji, Sharath S.

    2015-01-01

    Highlights: • The existence of the slow manifold for the air-mixture system is shown. • The QSSA estimate of the slow manifold is fairly accurate. • For mid-temperature range the reduction mechanisms could be useful. - Abstract: In external hypersonic flows, viscous and compressibility effects generate very high temperatures leading to significant chemical reactions among air constituents. Therefore, hypersonic flow computations require coupled calculations of flow and chemistry. Accurate and efficient computations of air-chemistry kinetics are of much importance for many practical applications but calculations accounting for detailed chemical kinetics can be prohibitively expensive. In this paper, we investigate the possibility of applying chemical kinetics reduction schemes for hypersonic air-chemistry. We consider two chemical kinetics sets appropriate for three different temperature ranges: 2500 K to 4500 K; 4500 K to 9000 K; and above 9000 K. By demonstrating the existence of the so-called the slow manifold in each of the chemistry sets, we show that judicious chemical kinetics reduction leading to significant computational savings is possible without much loss in accuracy

  15. Thermodynamic, Environmental and Economic Analyses of Solar Ejector Refrigeration System Application for Cold Storage

    İbrahim ÜÇGÜL

    2009-01-01

    The refrigeration processes have been widely applied for especially in cold storages. In these plants, the systems working with compressed vapour cooling cycles have been used as a classical method. In general, electrical energy is used for compressing in these processes. Although, mainly the electricity itself has no pollution effect on the environment, the fossil fuels that are widely used to produce electricity in the most of the world, affect the nature terribly. In short, these refrigera...

  16. Application of Cold Chain Logistics Safety Reliability in Fresh Food Distribution Optimization

    Zou Yifeng; Xie Ruhe

    2013-01-01

    In view of the nature of fresh food’s continuous decrease of safety during distribution process, this study applied safety reliability of food cold chain logistics to establish fresh food distribution routing optimization model with time windows, and solved the model using MAX-MIN Ant System (MMAS) with case analysis. Studies have shown that the mentioned model and algorithm can better solve the problem of fresh food distribution routing optimization with time windows.

  17. Application of Cold Storage for Raja Sere Banana (Musa acuminata colla)

    Crismas, S. R. S.; Purwanto, Y. A.; Sutrisno

    2018-05-01

    Raja Sere is one of the indigenous banana cultivars in Indonesia. This cultivar has a yellow color when ripen, small size and sweet taste. Traditionally, the growers market this banana cultivar to the market without any treatment to delay the ripening process. Banana fruits are commonly being harvested at the condition of hard green mature. At this condition of hard green mature, banana fruits can be stored for a long-term period. The objective of this study was to examine the effect of cold storage on the quality of raja sere banana that stored at 13°C. Banana fruits cultivar Raja Sere were harvested from local farmer field at the condition of hard green mature (about 14 weeks age after the flower bloom). Fifteen bunches of banana were stored in cold storage with a temperature of 13°C for 0, 3, 6, 9, and 12 days, respectively. For the control, room temperature storage (28°C) was used. At a storage period, samples of banana fruits ripened in the ripening chamber by injecting 100 ppm of ethylene gas at 25°C for 24 hours. The quality parameters namely respiration rate, hardness, total soluble solids (TSS), change in color, and weight loss were measured. For those banana fruits stored at room temperature, the shelf-life of banana was only reached up to 6 days. For those banana fruits stored in cold storage, the condition of banana fruits was reached up to 12 days. After cold storage and ripening, the third day measurement was the optimal time for bananas to be consumed which indicated by the yellow color (lightness value = 68.51, a* = 4.74 and value b* = 62.63), TSS 24.30 °Brix and hardness 0.48 kgf, weight loss about 7.53-16.45% and CO2 respiration rate of 100.37 mLCO2 / kg.hr.

  18. Muscle, Skin and Core Temperature after −110°C Cold Air and 8°C Water Treatment

    Costello, Joseph Thomas; Culligan, Kevin; Selfe, James; Donnelly, Alan Edward

    2012-01-01

    The aim of this investigation was to elucidate the reductions in muscle, skin and core temperature following exposure to −110°C whole body cryotherapy (WBC), and compare these to 8°C cold water immersion (CWI). Twenty active male subjects were randomly assigned to a 4-min exposure of WBC or CWI. A minimum of 7 days later subjects were exposed to the other treatment. Muscle temperature in the right vastus lateralis (n = 10); thigh skin (average, maximum and minimum) and rectal temperature (n = 10) were recorded before and 60 min after treatment. The greatest reduction (Psporting setting. PMID:23139763

  19. Modelling of nitric acid production in the Advanced Cold Process Canister due to irradiation of moist air

    Henshaw, J.

    1994-01-01

    This report summarises the work performed for SKB of Sweden on the modelling of nitric acid production in the gaseous environment of the Advanced Cold Process Canister (ACPC). The model solves the simultaneous chemical rate equations describing the radiation chemistry of He/Ar/N 2 /O 2 /H 2 O gas mixture, involving over 200 chemical reactions. The amount of nitric acid produced as a function of time for typical ACPC conditions has been calculated using the model and the results reported. 11 refs, 11 figs, 1 tab

  20. Environmental application of nanotechnology: air, soil, and water.

    Ibrahim, Rusul Khaleel; Hayyan, Maan; AlSaadi, Mohammed Abdulhakim; Hayyan, Adeeb; Ibrahim, Shaliza

    2016-07-01

    Global deterioration of water, soil, and atmosphere by the release of toxic chemicals from the ongoing anthropogenic activities is becoming a serious problem throughout the world. This poses numerous issues relevant to ecosystem and human health that intensify the application challenges of conventional treatment technologies. Therefore, this review sheds the light on the recent progresses in nanotechnology and its vital role to encompass the imperative demand to monitor and treat the emerging hazardous wastes with lower cost, less energy, as well as higher efficiency. Essentially, the key aspects of this account are to briefly outline the advantages of nanotechnology over conventional treatment technologies and to relevantly highlight the treatment applications of some nanomaterials (e.g., carbon-based nanoparticles, antibacterial nanoparticles, and metal oxide nanoparticles) in the following environments: (1) air (treatment of greenhouse gases, volatile organic compounds, and bioaerosols via adsorption, photocatalytic degradation, thermal decomposition, and air filtration processes), (2) soil (application of nanomaterials as amendment agents for phytoremediation processes and utilization of stabilizers to enhance their performance), and (3) water (removal of organic pollutants, heavy metals, pathogens through adsorption, membrane processes, photocatalysis, and disinfection processes).

  1. Why social network analysis is important to Air Force applications

    Havig, Paul R.; McIntire, John P.; Geiselman, Eric; Mohd-Zaid, Fairul

    2012-06-01

    Social network analysis is a powerful tool used to help analysts discover relationships amongst groups of people as well as individuals. It is the mathematics behind such social networks as Facebook and MySpace. These networks alone cause a huge amount of data to be generated and the issue is only compounded once one adds in other electronic media such as e-mails and twitter. In this paper we outline the basics of social network analysis and how it may be used in current and future Air Force applications.

  2. Recent Photocatalytic Applications for Air Purification in Belgium

    Elia Boonen

    2014-07-01

    Full Text Available Photocatalytic concrete constitutes a promising technique to reduce a number of air contaminants such as NOx and VOC’s, especially at sites with a high level of pollution: highly trafficked canyon streets, road tunnels, the urban environment, etc. Ideally, the photocatalyst, titanium dioxide, is introduced in the top layer of the concrete pavement for best results. In addition, the combination of TiO2 with cement-based products offers some synergistic advantages, as the reaction products can be adsorbed at the surface and subsequently be washed away by rain. A first application has been studied by the Belgian Road Research Center (BRRC on the side roads of a main entrance axis in Antwerp with the installation of 10.000 m² of photocatalytic concrete paving blocks. For now however, the translation of laboratory testing towards results in situ remains critical of demonstrating the effectiveness in large scale applications. Moreover, the durability of the air cleaning characteristic with time remains challenging for application in concrete roads. From this perspective, several new trial applications have been initiated in Belgium in recent years to assess the “real life” behavior, including a field site set up in the Leopold II tunnel of Brussels and the construction of new photocatalytic pavements on industrial zones in the cities of Wijnegem and Lier (province of Antwerp. This paper first gives a short overview of the photocatalytic principle applied in concrete, to continue with some main results of the laboratory research recognizing the important parameters that come into play. In addition, some of the methods and results, obtained for the existing application in Antwerp (2005 and during the implementation of the new realizations in Wijnegem and Lier (2010–2012 and in Brussels (2011–2013, will be presented.

  3. Performance of alternative refrigerants for residential air-conditioning applications

    Park, Ki-Jung; Seo, Taebeom; Jung, Dongsoo

    2007-01-01

    In this study, performances of two pure hydrocarbons and seven mixtures composed of propylene, propane, HFC152a, and dimethylether were measured to substitute for HCFC22 in residential air-conditioners and heat pumps. Thermodynamic cycle analysis was carried out to determine the optimum compositions before testing and actual tests were performed in a breadboard-type laboratory heat pump/air-conditioner at the evaporation and condensation temperatures of 7 and 45 deg. C, respectively. Test results show that the coefficient of performance of these mixtures is up to 5.7% higher than that of HCFC22. While propane showed a 11.5% reduction in capacity, most of the fluids had a similar capacity to that of HCFC22. For these fluids, compressor-discharge temperatures were reduced by 11-17 deg. C. For all fluids tested, the amount of charge was reduced by up to 55% as compared to HCFC22. Overall, these fluids provide good performances with reasonable energy-savings without any environmental problem and thus can be used as long-term alternatives for residential air-conditioning and heat-pumping applications

  4. Study on heat collector of the solar system utilizing outdoor air. Experimental results in cases of cold and warm regions; Gaiki donyushiki solar system no shunetsubu ni kansuru kenkyu. Kanreichi to ondanchi ni okeru shunetsu jikken to kosatsu

    Komano, S; Ebara, Y [OM Solar Association, Shizuoka (Japan); Wada, H [Wada Building Constructors Co. Ltd., Hokkaido (Japan)

    1996-10-27

    An experiment on heat collection was made in the heat collector of a solar system utilizing outdoor air in cold and warm regions. In this system, outdoor air is heated by the air circulation layer on the roof exposed to solar radiation. The heated air is supplied to the object space for heating and ventilation. In the experiment in a cold region, the heat collection characteristics can be adjusted by putting a baffle plate in the air duct according to the experiment of a glass heat collector. The heat collecting air layer on only the iron roof may leak or freeze in the region subject to coldness or heavy snowfall. Therefore, preheat forms the space of a garret, and the preheat temperature comparatively becomes low. The data in which the heat collection characteristics can be adjusted using only a glass heat collector is required corresponding to the regional situation. In the experiment in a warm region, an experiment was made inclusive of the preheat for which outdoor air is absorbed at the eaves. As a result, the heat collection characteristics of preheat were improved. Moreover, a heat collection temperature of about 60{degree}C was obtained on the heat collection surface including the preheat. 1 ref., 12 figs., 3 tabs.

  5. 78 FR 63273 - Notice of Applications for Certificates of Public Convenience and Necessity and Foreign Air...

    2013-10-23

    ... Public Convenience and Necessity and Foreign Air Carrier Permits Filed Under Subpart B (Formerly Subpart Q) Notice of Applications for Certificates of Public Convenience and Necessity and Foreign Air... following Applications for Certificates of Public Convenience and Necessity and Foreign Air Carrier Permits...

  6. Application of Nanofibrillated Cellulose on BOPP/LDPE Film as Oxygen Barrier and Antimicrobial Coating Based on Cold Plasma Treatment

    Peng Lu

    2018-05-01

    Full Text Available The application of nanofibrillated cellulose (NC films in packaging industry has been hindered by its lack of heat-sealing ability. Incorporation of NC films with the biaxially oriented polypropylene/low density polyethylene (BOPP/LDPE laminates can take advantage of each material and endow the films with novel functions for food packaging applications. In this study, a coating that consists of NC and nisin was applied onto a cold plasma treated BOPP/LDPE film to fabricate a novel active packaging with an improved oxygen barrier performance and an added antimicrobial effect. The results showed that cold plasma treatment improved the surface hydrophilicity of BOPP/LDPE films for better attachment of the coatings. NC coatings significantly enhanced oxygen barrier property of the BOPP/LDPE film, with an oxygen transmission rate as low as 24.02 cc/m2·day as compared to that of the non-coated one (67.03 cc/m2·day. The addition of nisin in the coating at a concentration of 5 mg/g caused no significant change in barrier properties but imparted the film excellent antimicrobial properties, with a growth inhibition of L. monocytogenes by 94%. All films exhibit satisfying mechanical properties and transparency, and this new film has the potential to be used as antimicrobial and oxygen barrier packaging.

  7. Heat capacity changes in RNA folding: application of perturbation theory to hammerhead ribozyme cold denaturation.

    Mikulecky, Peter J; Feig, Andrew L

    2004-01-01

    In proteins, empirical correlations have shown that changes in heat capacity (DeltaC(P)) scale linearly with the hydrophobic surface area buried upon folding. The influence of DeltaC(P) on RNA folding has been widely overlooked and is poorly understood. In addition to considerations of solvent reorganization, electrostatic effects might contribute to DeltaC(P)s of folding in polyanionic species such as RNAs. Here, we employ a perturbation method based on electrostatic theory to probe the hot and cold denaturation behavior of the hammerhead ribozyme. This treatment avoids much of the error associated with imposing two-state folding models on non-two-state systems. Ribozyme stability is perturbed across a matrix of solvent conditions by varying the concentration of NaCl and methanol co-solvent. Temperature-dependent unfolding is then monitored by circular dichroism spectroscopy. The resulting array of unfolding transitions can be used to calculate a DeltaC(P) of folding that accurately predicts the observed cold denaturation temperature. We confirm the accuracy of the calculated DeltaC(P) by using isothermal titration calorimetry, and also demonstrate a methanol-dependence of the DeltaC(P). We weigh the strengths and limitations of this method for determining DeltaC(P) values. Finally, we discuss the data in light of the physical origins of the DeltaC(P)s for RNA folding and consider their impact on biological function.

  8. Investigation of slip transfer across HCP grain boundaries with application to cold dwell facet fatigue

    Zheng, Zebang; Balint, Daniel S.; Dunne, Fionn P.E.

    2017-01-01

    This paper addresses the role of grain boundary slip transfer and thermally-activated discrete dislocation plasticity in the redistribution of grain boundary stresses during cold dwell fatigue in titanium alloys. Atomistic simulations have been utilised to calculate the grain boundary energies for titanium with respect to the misorientation angles. The grain boundary energies are utilised within a thermally-activated discrete dislocation plasticity model incorporating slip transfer controlled by energetic and grain boundary geometrical criteria. The model predicts the grain size effect on the flow strength in Ti alloys. Cold dwell fatigue behaviour in Ti-6242 alloy is investigated and it is shown that significant stress redistribution from soft to hard grains occurs during the stress dwell, which is observed both for grain boundaries for which slip transfer is permitted and inhibited. However, the grain boundary slip penetration is shown to lead to significantly higher hard-grain basal stresses near the grain boundary after dwell, thus exacerbating the load shedding stress compared to an impenetrable grain boundary. The key property controlling the dwell fatigue response is argued to remain the time constant associated with the thermal activation process for dislocation escape, but the slip penetrability is also important and exacerbates the load shedding. The inclusion of a macrozone does not significantly change the conclusions but does potentially lead to the possibility of a larger initial facet.

  9. Evaporative cooling enhanced cold storage system

    Carr, P.

    1991-10-15

    The invention provides an evaporatively enhanced cold storage system wherein a warm air stream is cooled and the cooled air stream is thereafter passed into contact with a cold storage unit. Moisture is added to the cooled air stream prior to or during contact of the cooled air stream with the cold storage unit to effect enhanced cooling of the cold storage unit due to evaporation of all or a portion of the added moisture. Preferably at least a portion of the added moisture comprises water condensed during the cooling of the warm air stream. 3 figures.

  10. Adobe AIR 15 Cookbook Solutions and Examples for Rich Internet Application Developers

    Tucker, David; DeWeggheleire, Koen

    2008-01-01

    The hands-on recipes in this cookbook help you solve a variety of tasks and scenarios often encountered when using Adobe AIR to build Rich Internet Applications for the desktop. Thoroughly vetted by Adobe's AIR development team, Adobe AIR 1.5 Cookbook addresses fundamentals, best practices, and more. If you want to learn the nuances of Adobe AIR to build innovative applications, this is the book you've been waiting for.

  11. PCM thermal storage design in buildings: Experimental studies and applications to solaria in cold climates

    Guarino, Francesco; Athienitis, Andreas; Cellura, Maurizio; Bastien, Diane

    2017-01-01

    Highlights: • This paper analyzes the performance of a building-integrated thermal storage system. • A wall opposing a glazed surface serves as phase change materials thermal storage. • The study is based on both experimental and simulation studies. • Heat is stored and released up to 6–8 h after solar irradiation. • Yearly heating requirements are reduced by 17% in a cold climate. - Abstract: As energy availability and demand often do not match, thermal energy storage plays a crucial role to take advantage of solar radiation in buildings: in particular, latent heat storage via phase-change material is particularly attractive due to its ability to provide high energy storage density. This paper analyzes the performance of a building-integrated thermal storage system to increase the energy performances of solaria in a cold climate. A wall opposing a highly glazed façade (south oriented) is used as thermal storage with phase change materials embedded in the wall. The study is based on both experimental and simulation studies. The concept considered is particularly suited to retrofits in a solarium since the PCM can be added as layers facing the large window on the vertical wall directly opposite. Results indicate that this PCM thermal storage system is effective during the whole year in a cold climate. The thermal storage allows solar radiation to be stored and released up to 6–8 h after solar irradiation: this has effects on both the reduction of daily temperature swings (up to 10 °C) and heating requirements (more than 17% on a yearly base). Coupling of the thermal storage system with natural ventilation is important during mid-seasons and summer to improve the PCM charge-discharge cycles and to reduce overheating. Results also show that cooling is less important than heating, reaching up to 20% of the overall annual energy requirements for the city of Montreal, Canada. Moreover, the phase change temperature range of the material used (18–24

  12. The 1998 bible. Cold production, air conditioning, big cooking installations; La bible 1998. Froid, climatisation, grandes cuisines

    NONE

    1998-12-31

    This manual is devoted to French professionals of thermal engineering. It contains all useful addresses of companies involved in the manufacturing, distribution and maintenance of air conditioning and refrigerating systems, a list of companies classified by products and activities, a departmental list of distribution companies, an alphabetical list of professional organizations, a catalog of the new products of the year, and the recent regulatory texts concerning the confinement of refrigerating installations. (J.S.)

  13. The accelerating effects of the microorganisms on biodeterioration of stone monuments under air pollution and continental-cold climatic conditions in Erzurum, Turkey

    Nuhoglu, Y.; Oguz, E.; Uslu, H.; Ozbek, A.; Ipekoglu, B.; Ocak, I.; Hasenekoglu, I.

    2006-01-01

    The aim of this research was to determine the accelerating effects of microorganisms on the biodeterioration of stone under air pollution and continental-cold climatic region in Erzurum, Turkey. Studies have been carried out on specimens of the Rustempasa Bazaar, the Lalapasa Mosque, the Erzurum Castle Mosque, the Double Minarets-Madrasah, the Great Mosque and the Haji Mehmet Fountain aged from 441 to 823 years old. The results showed that vegetative and reproductive (generative) forms of the microorganisms could develop during the winter months when the night time average temperature was even - 25 deg. C. Also the reproductive forms had developed and the whole stone surface was covered with a biofilm caused by the microorganisms. Silicon, aluminum, calcium, potassium, titanium, magnesium, zinc, sulfur, iron, sodium, and niobium were found in the stones of the historical buildings with varying amounts through the SEM-EDS analysis. Some of these elements could be used as an energy resource for the microorganisms together with the air pollutants such as sulfur dioxide, nitrogen oxides and particles on the stone surfaces. Of 21 isolates, 15 species from 6 bacterium genera and 5 species from 5 fungi genera plus 1 fungi genera were identified on the deteriorated stone surfaces even during the coldest months by microbial identification system (MIS) and these findings were tested by SEM investigations

  14. Physicochemical and technological aspects of application of anthracite of Nazar-Aylok Deposit for production of cold-bottom hearth mass

    Vokhidov, M.M.

    2017-01-01

    The present work is devoted to physicochemical and technological aspects of application of anthracite of Nazar-Aylok Deposit for production of cold-bottom hearth mass. The purpose of present work is to study the composition and physicochemical properties of initial and calcined anthracite of Nazar-Aylok Deposit, revelation of optimal parameters of its thermal treatment. Therefore, the structure, composition and physicochemical properties of anthracite of Nazar-Aylok Deposit have been studied by means of chemical, thermographic, X-ray, electron paramagnetic resonance and infrared spectroscopy methods; physicochemical and mechanical properties of cold-bottom hearth mass produced at various mass ratio of filler, binding and plasticizer have been studied as well; the flowsheets of production of cold-bottom hearth mass with the usage of anthracite of Nazar-Aylok Deposit have been elaborated; the pilot bitch of cold-bottom hearth mass has been produced and tested at industrial scale.

  15. Muscle Reaction Time During a Simulated Lateral Ankle Sprain After Wet-Ice Application or Cold-Water Immersion.

    Thain, Peter K; Bleakley, Christopher M; Mitchell, Andrew C S

    2015-07-01

    Cryotherapy is used widely in sport and exercise medicine to manage acute injuries and facilitate rehabilitation. The analgesic effects of cryotherapy are well established; however, a potential caveat is that cooling tissue negatively affects neuromuscular control through delayed muscle reaction time. This topic is important to investigate because athletes often return to exercise, rehabilitation, or competitive activity immediately or shortly after cryotherapy. To compare the effects of wet-ice application, cold-water immersion, and an untreated control condition on peroneus longus and tibialis anterior muscle reaction time during a simulated lateral ankle sprain. Randomized controlled clinical trial. University of Hertfordshire human performance laboratory. A total of 54 physically active individuals (age = 20.1 ± 1.5 years, height = 1.7 ± 0.07 m, mass = 66.7 ± 5.4 kg) who had no injury or history of ankle sprain. Wet-ice application, cold-water immersion, or an untreated control condition applied to the ankle for 10 minutes. Muscle reaction time and muscle amplitude of the peroneus longus and tibialis anterior in response to a simulated lateral ankle sprain were calculated. The ankle-sprain simulation incorporated a combined inversion and plantar-flexion movement. We observed no change in muscle reaction time or muscle amplitude after cryotherapy for either the peroneus longus or tibialis anterior (P > .05). Ten minutes of joint cooling did not adversely affect muscle reaction time or muscle amplitude in response to a simulated lateral ankle sprain. These findings suggested that athletes can safely return to sporting activity immediately after icing. Further evidence showed that ice can be applied before ankle rehabilitation without adversely affecting dynamic neuromuscular control. Investigation in patients with acute ankle sprains is warranted to assess the clinical applicability of these interventions.

  16. 14 CFR 330.25 - What are the components of an air carrier's application for compensation?

    2010-01-01

    ... 14 Aeronautics and Space 4 2010-01-01 2010-01-01 false What are the components of an air carrier's application for compensation? 330.25 Section 330.25 Aeronautics and Space OFFICE OF THE SECRETARY, DEPARTMENT... CARRIERS Application Procedures § 330.25 What are the components of an air carrier's application for...

  17. Following the Flag: An Air Force Officer Provides an Eyewitness View of Major Events and Policies during the Cold War

    2010-03-01

    940. The First Pursuit Group of the Army Air Corps (AAC) did its gun- nery training at Phelps-Collins Airport near my hometown of WEST POINT 2 Alpena ...Apparently the MiGs were on a radar approach to Antung, their base just across the Yalu. What to do? “Dreams of glory— Alpena lieutenant gets four MiGs on...unintended result. Highest and Fastest The first time I flew was in an old Ford trimotor transport from Alpena to Detroit. I was about 14. An early memory

  18. Measuring Device for Air Speed in Macroporous Media and Its Application Inside Apple Storage Bins

    Martin Geyer

    2018-02-01

    Full Text Available In cold storage facilities of fruit and vegetables, airflow is necessary for heat removal. The design of storage facilities influences the air speed in the surrounding of the product. Therefore, knowledge about airflow next to the product is important to plan the layout of cold stores adapted to the requirements of the products. A new sensing device (ASL, Air speed logger is developed for omnidirectional measurement of air speed between fruit or vegetables inside storage bins or in bulk. It consists of four interconnected plastic spheres with 80 mm diameter each, adapted to the size of apple fruit. In the free space between the spheres, silicon diodes are fixed for the airflow measurement based on a calorimetric principle. Battery and data logger are mounted inside the spheres. The device is calibrated in a wind tunnel in a measuring range of 0–1.3 m/s. Air speed measurements in fruit bulks on laboratory scale and in an industrial fruit store show air speeds in gaps between fruit with high stability at different airflow levels. Several devices can be placed between stored products for determination of the air speed distribution inside bulks or bin stacks in a storage room.

  19. High-Energy Electron Beam Application to Air Pollutants Removal

    Ighigeanu, D.; Martin, D.; Manaila, E.; Craciun, G.; Calinescu, I.

    2009-01-01

    The advantage of electron beam (EB) process in pollutants removal is connected to its high efficiency to transfer high amount of energy directly into the matter under treatment. Disadvantage which is mostly related to high investment cost of accelerator may be effectively overcome in future as the result of use accelerator new developments. The potential use of medium to high-energy high power EB accelerators for air pollutants removal is demonstrated in [1]. The lower electrical efficiencies of accelerators with higher energies are partially compensated by the lower electron energy losses in the beam windows. In addition, accelerators with higher electron energies can provide higher beam powers with lower beam currents [1]. The total EB energy losses (backscattering, windows and in the intervening air space) are substantially lower with higher EB incident energy. The useful EB energy is under 50% for 0.5 MeV and about 95% above 3 MeV. In view of these arguments we decided to study the application of high energy EB for air pollutants removal. Two electron beam accelerators are available for our studies: electron linear accelerators ALIN-10 and ALID-7, built in the Electron Accelerator Laboratory, INFLPR, Bucharest, Romania. Both accelerators are of traveling-wave type, operating at a wavelength of 10 cm. They utilize tunable S-band magnetrons, EEV M 5125 type, delivering 2 MW of power in 4 μ pulses. The accelerating structure is a disk-loaded tube operating in the 2 mode. The optimum values of the EB peak current IEB and EB energy EEB to produce maximum output power PEB for a fixed pulse duration EB and repetition frequency fEB are as follows: for ALIN-10: EEB = 6.23 MeV; IEB =75 mA; PEB 164 W (fEB = 100 Hz, EB = 3.5 s) and for ALID-7: EEB 5.5 MeV; IEB = 130 mA; PEB = 670 W (fEB = 250 Hz, EB = 3.75 s). This paper presents a special designed installation, named SDI-1, and several representative results obtained by high energy EB application to SO 2 , NOx and VOCs

  20. A comparative study of different methods for the generation of tetra-n-butyl ammonium bromide clathrate hydrate slurry in a cold storage air-conditioning system

    Shi, X.J.; Zhang, P.

    2013-01-01

    Highlights: ► Four kinds of TBAB CHS generation methods are experimentally investigated. ► Accession of CHS into supercooled solution can be helpful to the generation. ► Higher flow rate results in higher energy efficiency of CHS generation. - Abstract: A cold storage air-conditioning system using tetra-n-butyl ammonium bromide (TBAB) clathrate hydrate slurry (CHS) as cold storage medium was built to investigate the high-efficiency method of TBAB CHS generation. In the present study, four kinds of different TBAB CHS generation methods were experimentally investigated and compared, and these methods included continuously cooling, turning off refrigerator while crystals appearing, supercooling release and accession of TBAB CHS into supercooled TBAB aqueous solution. The results showed that continuously cooling would lead to severe adhesion of crystal to the heat exchanger wall, and supercooling release took place with a big stochastic characteristic, hence the first and third method were concluded not reliable. Both the second and fourth methods could maintain the temperature of heat exchanger wall at a relatively higher level, therefore the crystal adhesion to the heat exchanger wall would be reduced significantly, which led to higher coefficient of performance (COP). In addition, accession of TBAB CHS into TBAB supercooled solution could shorten the time of supercooling release, resulting in about 21.8–35.4% shorter generation time than other methods. Moreover, the influence of flow rate on the CHS generation process was investigated, and the results showed that higher flow rate generally resulted in higher system COP

  1. Simple surface foam application enhances bioremediation of oil-contaminated soil in cold conditions.

    Jeong, Seung-Woo; Jeong, Jongshin; Kim, Jaisoo

    2015-04-09

    Landfarming of oil-contaminated soil is ineffective at low temperatures, because the number and activity of micro-organisms declines. This study presents a simple and versatile technique for bioremediation of diesel-contaminated soil, which involves spraying foam on the soil surface without additional works such as tilling, or supply of water and air. Surfactant foam containing psychrophilic oil-degrading microbes and nutrients was sprayed twice daily over diesel-contaminated soil at 6 °C. Removal efficiencies in total petroleum hydrocarbon (TPH) at 30 days were 46.3% for landfarming and 73.7% for foam-spraying. The first-order kinetic biodegradation rates for landfarming and foam-spraying were calculated as 0.019 d(-1) and 0.044 d(-1), respectively. Foam acted as an insulating medium, keeping the soil 2 °C warmer than ambient air. Sprayed foam was slowly converted to aqueous solution within 10-12h and infiltrated the soil, providing microbes, nutrients, water, and air for bioaugmentation. Furthermore, surfactant present in the aqueous solution accelerated the dissolution of oil from the soil, resulting in readily biodegradable aqueous form. Significant reductions in hydrocarbon concentration were simultaneously observed in both semi-volatile and non-volatile fractions. As the initial soil TPH concentration increased, the TPH removal rate of the foam-spraying method also increased. Copyright © 2014 Elsevier B.V. All rights reserved.

  2. Hot-rolled and cold-finished zirconium and zirconium alloy bars, rod, and wire for nuclear application

    Anon.

    1981-01-01

    The specification covers hot- and cold-finished zirconium alloy bars, rod, and wire, other than those required for reforging, including rounds, squares, and shapes. One unalloyed grade and three alloy grades for use in nuclear applications are described. The products covered include the following sections and sizes: bars, rounds in coils for subsequent reworking (6.4 to 19 mm) and flats (6.4 to 250 mm); rods, rounds in coils for subsequent reworking (6.4 to 19 mm); wire (9.5 mm). The specification covers ordering information, manufacture, condition, chemical requirements, mechanical properties, corrosion properties, permissible variations in dimensions, significance of numerical limits, lot size, special tests, workmanship, finish, inspection, certification, packaging and marking

  3. Applicability research on passive design of residential buildings in hot summer and cold winter zone in China

    Zhang, Hui; Wang, Huihui; Zhou, Xuan

    2017-04-01

    Passive design has long been a concern as an effective way of building energy efficiency. However, different urban climate characteristics determine the time-effectiveness of passive design. According to the climate characteristics of hot summer and cold winter zone in China, this research chose five cities, Shanghai, Wuhan, Chongqing, Nanjing and Changsha, to analyze their residential building energy consumption and thermal environment conditions. Based on Weather Tool calculation and analysis, the purpose of this research is to put forward the concept of Suitable Degree (SD), namely the applicability of the passive design. In addition, five cities’ SD of passive design technology had been analyzed from aspect of ventilation, temperature, solar radiation and envelope, then passive design strategies and methods of five cities’ residential building were discussed.

  4. Temperature ranges of the application of air-to-air heat recovery ventilator in supermarkets in winter, China

    Kang, Yanming; Wang, Youjun; Zhong, Ke [School of Environmental Science and Engineering, Donghua University, Shanghai 201620 (China); Liu, Jiaping [School of Architecture, Xi' an University of Architecture and Technology, Xi' an 710055 (China)

    2010-12-15

    Energy consumption is an important issue in China. In heating, ventilation and air conditioning (HVAC) systems, more and more commercial buildings use air-to-air heat recovery ventilators as energy saving units for recovering heat from the exhaust air in ventilation systems in current years. In the present paper, critical temperatures of air-to-air heat recovery systems for supermarkets in winter are recommended and discussed for the four cities in different climate zones of China. The analysis shows that the temperature of fresh air in winter can be categorized into three regions, i.e., recovery region, transition region and impermissible recovery region. The results also indicate that the latent heat recovery is not suitable for ventilation energy savings in supermarkets in winter. Meanwhile, the applicability of sensible heat recovery in supermarkets depends on outdoor climate and fresh air flow rate. If a variable rotational speed fan is used to introduce fresh air into the building, heat recovery does always function as planned in winter for all the selected cities except Guangzhou, and most values of the COP are much higher than 2.5. Otherwise, there is the risk of negative impact on building energy savings in all cities except Harbin. (author)

  5. Muscle, skin and core temperature after -110°c cold air and 8°c water treatment.

    Costello, Joseph Thomas; Culligan, Kevin; Selfe, James; Donnelly, Alan Edward

    2012-01-01

    The aim of this investigation was to elucidate the reductions in muscle, skin and core temperature following exposure to -110°C whole body cryotherapy (WBC), and compare these to 8°C cold water immersion (CWI). Twenty active male subjects were randomly assigned to a 4-min exposure of WBC or CWI. A minimum of 7 days later subjects were exposed to the other treatment. Muscle temperature in the right vastus lateralis (n=10); thigh skin (average, maximum and minimum) and rectal temperature (n=10) were recorded before and 60 min after treatment. The greatest reduction (P<0.05) in muscle (mean ± SD; 1 cm: WBC, 1.6 ± 1.2°C; CWI, 2.0 ± 1.0°C; 2 cm: WBC, 1.2 ± 0.7°C; CWI, 1.7 ± 0.9°C; 3 cm: WBC, 1.6 ± 0.6°C; CWI, 1.7 ± 0.5°C) and rectal temperature (WBC, 0.3 ± 0.2°C; CWI, 0.4 ± 0.2°C) were observed 60 min after treatment. The largest reductions in average (WBC, 12.1 ± 1.0°C; CWI, 8.4 ± 0.7°C), minimum (WBC, 13.2 ± 1.4°C; CWI, 8.7 ± 0.7°C) and maximum (WBC, 8.8 ± 2.0°C; CWI, 7.2 ± 1.9°C) skin temperature occurred immediately after both CWI and WBC (P<0.05). Skin temperature was significantly lower (P<0.05) immediately after WBC compared to CWI. The present study demonstrates that a single WBC exposure decreases muscle and core temperature to a similar level of those experienced after CWI. Although both treatments significantly reduced skin temperature, WBC elicited a greater decrease compared to CWI. These data may provide information to clinicians and researchers attempting to optimise WBC and CWI protocols in a clinical or sporting setting.

  6. Muscle, skin and core temperature after -110°c cold air and 8°c water treatment.

    Joseph Thomas Costello

    Full Text Available The aim of this investigation was to elucidate the reductions in muscle, skin and core temperature following exposure to -110°C whole body cryotherapy (WBC, and compare these to 8°C cold water immersion (CWI. Twenty active male subjects were randomly assigned to a 4-min exposure of WBC or CWI. A minimum of 7 days later subjects were exposed to the other treatment. Muscle temperature in the right vastus lateralis (n=10; thigh skin (average, maximum and minimum and rectal temperature (n=10 were recorded before and 60 min after treatment. The greatest reduction (P<0.05 in muscle (mean ± SD; 1 cm: WBC, 1.6 ± 1.2°C; CWI, 2.0 ± 1.0°C; 2 cm: WBC, 1.2 ± 0.7°C; CWI, 1.7 ± 0.9°C; 3 cm: WBC, 1.6 ± 0.6°C; CWI, 1.7 ± 0.5°C and rectal temperature (WBC, 0.3 ± 0.2°C; CWI, 0.4 ± 0.2°C were observed 60 min after treatment. The largest reductions in average (WBC, 12.1 ± 1.0°C; CWI, 8.4 ± 0.7°C, minimum (WBC, 13.2 ± 1.4°C; CWI, 8.7 ± 0.7°C and maximum (WBC, 8.8 ± 2.0°C; CWI, 7.2 ± 1.9°C skin temperature occurred immediately after both CWI and WBC (P<0.05. Skin temperature was significantly lower (P<0.05 immediately after WBC compared to CWI. The present study demonstrates that a single WBC exposure decreases muscle and core temperature to a similar level of those experienced after CWI. Although both treatments significantly reduced skin temperature, WBC elicited a greater decrease compared to CWI. These data may provide information to clinicians and researchers attempting to optimise WBC and CWI protocols in a clinical or sporting setting.

  7. 76 FR 20435 - Notice of Applications for Certificates of Public Convenience and Necessity and Foreign Air...

    2011-04-12

    ... Public Convenience and Necessity and Foreign Air Carrier Permits Notice of Applications for Certificates of Public Convenience and Necessity and Foreign Air Carrier Permits Filed Under Subpart B (formerly... Convenience and Necessity and Foreign Air Carrier Permits were filed under Subpart B (formerly Subpart Q) of...

  8. 77 FR 45715 - Application of Key Lime Air Corporation for Commuter Authority

    2012-08-01

    ... DEPARTMENT OF TRANSPORTATION Office of the Secretary [Docket DOT-OST-2009-0116] Application of Key Lime Air Corporation for Commuter Authority AGENCY: Department of Transportation. ACTION: Notice of... Lime Air Corporation fit, willing, and able, and awarding it a Commuter Air Carrier Authorization...

  9. 75 FR 12328 - Application of Charter Air Transport, Inc. for Commuter Authority

    2010-03-15

    ... DEPARTMENT OF TRANSPORTATION Office of the Secretary Application of Charter Air Transport, Inc... interested persons to show cause why it should not issue an order finding Charter Air Transport, Inc., fit, willing, and able, and awarding it Commuter Air Carrier Authorization. DATES: Persons wishing to file...

  10. Some like it hot, some like it cold: Temperature dependent biotechnological applications and improvements in extremophilic enzymes.

    Siddiqui, Khawar Sohail

    2015-12-01

    The full biotechnological exploitation of enzymes is still hampered by their low activity, low stability and high cost. Temperature-dependent catalytic properties of enzymes are a key to efficient and cost-effective translation to commercial applications. Organisms adapted to temperature extremes are a rich source of enzymes with broad ranging thermal properties which, if isolated, characterized and their structure-function-stability relationship elucidated, could underpin a variety of technologies. Enzymes from thermally-adapted organisms such as psychrophiles (low-temperature) and thermophiles (high-temperature) are a vast natural resource that is already under scrutiny for their biotechnological potential. However, psychrophilic and thermophilic enzymes show an activity-stability trade-off that necessitates the use of various genetic and chemical modifications to further improve their properties to suit various industrial applications. This review describes in detail the properties and biotechnological applications of both cold-adapted and thermophilic enzymes. Furthermore, the review critically examines ways to improve their value for biotechnology, concluding by proposing an integrated approach involving thermally-adapted, genetically and magnetically modified enzymes to make biocatalysis more efficient and cost-effective. Copyright © 2015 Elsevier Inc. All rights reserved.

  11. Air Conditioning Compressor Air Leak Detection by Image Processing Techniques for Industrial Applications

    Pookongchai Kritsada

    2015-01-01

    Full Text Available This paper presents method to detect air leakage of an air conditioning compressor using image processing techniques. Quality of air conditioning compressor should not have air leakage. To test an air conditioning compressor leak, air is pumped into a compressor and then submerged into the water tank. If air bubble occurs at surface of the air conditioning compressor, that leakage compressor must be returned for maintenance. In this work a new method to detect leakage and search leakage point with high accuracy, fast, and precise processes was proposed. In a preprocessing procedure to detect the air bubbles, threshold and median filter techniques have been used. Connected component labeling technique is used to detect the air bubbles while blob analysis is searching technique to analyze group of the air bubbles in sequential images. The experiments are tested with proposed algorithm to determine the leakage point of an air conditioning compressor. The location of the leakage point was presented as coordinated point. The results demonstrated that leakage point during process could be accurately detected. The estimation point had error less than 5% compared to the real leakage point.

  12. Applications of air ion measurement in environmental diagnostics

    Tammet, H.

    1996-01-01

    The present paper is dealing with the methods employing the measuring of naturally created air ions. The amount and mobility distribution of these ions offer hidden information about air pollution. On the other hand, the natural air ions are active in some environmental processes and they should be considered as an immediate environmental factor

  13. Cold plate

    Marroquin, Christopher M.; O' Connell, Kevin M.; Schultz, Mark D.; Tian, Shurong

    2018-02-13

    A cold plate, an electronic assembly including a cold plate, and a method for forming a cold plate are provided. The cold plate includes an interface plate and an opposing plate that form a plenum. The cold plate includes a plurality of active areas arranged for alignment over respective heat generating portions of an electronic assembly, and non-active areas between the active areas. A cooling fluid flows through the plenum. The plenum, at the non-active areas, has a reduced width and/or reduced height relative to the plenum at the active areas. The reduced width and/or height of the plenum, and exterior dimensions of cold plate, at the non-active areas allow the non-active areas to flex to accommodate surface variations of the electronics assembly. The reduced width and/or height non-active areas can be specifically shaped to fit between physical features of the electronics assembly.

  14. State of Washington Department of Health Radioactive air emissions notice of construction phase 1 for spent nuclear fuel project - cold vacuum drying facility, project W-441

    Turnbaugh, J.E.

    1996-08-15

    This notice of construction (NOC) provides information regarding the source and the estimated annual possession quantity resulting from operation of the Cold Vacuum Drying Facility (CVDF). Additional details on emissions generated by the operation of the CVDF will be discussed again in the Phase 11 NOC. This document serves as a NOC pursuant to the requirements of WAC 246-247-060 for the completion of Phase I NOC, defined as the pouring of concrete for the foundation flooring, construction of external walls, and construction of the building excluding the installation of CVDF process equipment. A Phase 11 NOC will be submitted for approval prior to installing and is defined as the completion of the CVDF, which consisted installation of process equipment, air emissions control, and emission monitoring equipment. About 80 percent of the U.S. Department of Energy`s spent nuclear fuel (SNF) inventory is stored under water in the Hanford Site K Basins. Spent nuclear fuel in the K West Basin is contained in closed canisters while the SNF in the K East Basin is in open canisters, which allow free release of corrosion products to the K East Basin water.

  15. Amine-based post-combustion CO2 capture in air-blown IGCC systems with cold and hot gas clean-up

    Giuffrida, A.; Bonalumi, D.; Lozza, G.

    2013-01-01

    Highlights: • Hot fuel gas clean-up is a very favorable technology for IGCC concepts. • IGCC net efficiency reduces to 41.5% when realizing post-combustion CO 2 capture. • Complex IGCC layouts are necessary if exhaust gas recirculation is realized. • IGCC performance does not significantly vary with exhaust gas recirculation. - Abstract: This paper focuses on the thermodynamic performance of air-blown IGCC systems with post-combustion CO 2 capture by chemical absorption. Two IGCC technologies are investigated in order to evaluate two different strategies of coal-derived gas clean-up. After outlining the layouts of two power plants, the first with conventional cold gas clean-up and the second with hot gas clean-up, attention is paid to the CO 2 capture station and to issues related to exhaust gas recirculation in combined cycles. The results highlight that significant improvements in IGCC performance are possible if hot coal-derived gas clean-up is realized before the syngas fuels the combustion turbine, so the energy cost of CO 2 removal in an amine-based post-combustion mode is less strong. In particular, IGCC net efficiency as high as 41.5% is calculated, showing an interesting potential if compared to the one of IGCC systems with pre-combustion CO 2 capture. Thermodynamic effects of exhaust gas recirculation are investigated as well, even though IGCC performance does not significantly vary against a more complicated plant layout

  16. The new exchangers in refrigeration and air, conditioning applications

    Marvillet, Ch [CEA, 38 - Grenoble (France). GRETh

    1998-12-31

    The investigation carried out by the `heat exchangers` network has revealed a number of points which should be noted here at the beginning of this presentation. It has been observed that most of today`s products (fin and tube heat exchangers) are designed along traditional lines. However despite this `conservatism`, a lot of attention is found on the technical and innovative techniques used in other areas of the world (particularly in Japan). Moreover, some of these innovative techniques (micro fin tubes, louvered fins) tend to be more frequently applied than others, and their gradual introduction into products which are `made in the EEC` is to be expected. The purpose of this paper is to respond, at least partially, to the interest shown by the industries contacted. during this investigation in these new techniques. In the first chapter, an overview of the information available today on high performance thermal heat exchange surfaces will be given. Micro-fin tubes and louvered fins will be the two surfaces considered in the first part of this document. According to this investigation, the fin and tube heat exchanger remains the only product available today for evaporating and condensing refrigerant applications using air as the fluid to be treated. Other technological solutions exist, however; brazed fin and plate heat exchangers commonly used in applications where compactness is an essential quality will be examined in the second part of this document. Moreover, the use of fluids which will replace CFCS in the years to come, and the possible comeback of ammonia will certainly have consequences on the design of evaporators and condensers. In the third part of this document the effects of these changes on fin and tube heat exchangers will be evaluated, and the first published results of the use of substitution fluids will be discussed. (author) 16 refs.

  17. The new exchangers in refrigeration and air, conditioning applications

    Marvillet, Ch. [CEA, 38 - Grenoble (France). GRETh

    1997-12-31

    The investigation carried out by the `heat exchangers` network has revealed a number of points which should be noted here at the beginning of this presentation. It has been observed that most of today`s products (fin and tube heat exchangers) are designed along traditional lines. However despite this `conservatism`, a lot of attention is found on the technical and innovative techniques used in other areas of the world (particularly in Japan). Moreover, some of these innovative techniques (micro fin tubes, louvered fins) tend to be more frequently applied than others, and their gradual introduction into products which are `made in the EEC` is to be expected. The purpose of this paper is to respond, at least partially, to the interest shown by the industries contacted. during this investigation in these new techniques. In the first chapter, an overview of the information available today on high performance thermal heat exchange surfaces will be given. Micro-fin tubes and louvered fins will be the two surfaces considered in the first part of this document. According to this investigation, the fin and tube heat exchanger remains the only product available today for evaporating and condensing refrigerant applications using air as the fluid to be treated. Other technological solutions exist, however; brazed fin and plate heat exchangers commonly used in applications where compactness is an essential quality will be examined in the second part of this document. Moreover, the use of fluids which will replace CFCS in the years to come, and the possible comeback of ammonia will certainly have consequences on the design of evaporators and condensers. In the third part of this document the effects of these changes on fin and tube heat exchangers will be evaluated, and the first published results of the use of substitution fluids will be discussed. (author) 16 refs.

  18. Cold adaptation, ca2+ dependency and autolytic stability are related features in a highly active cold-adapted trypsin resistant to autoproteolysis engineered for biotechnological applications.

    Alvaro Olivera-Nappa

    Full Text Available Pig trypsin is routinely used as a biotechnological tool, due to its high specificity and ability to be stored as an inactive stable zymogen. However, it is not an optimum enzyme for conditions found in wound debriding for medical uses and trypsinization processes for protein analysis and animal cell culturing, where low Ca(2+ dependency, high activity in mild conditions and easy inactivation are crucial. We isolated and thermodynamically characterized a highly active cold-adapted trypsin for medical and laboratory use that is four times more active than pig trypsin at 10(° C and at least 50% more active than pig trypsin up to 50(° C. Contrary to pig trypsin, this enzyme has a broad optimum pH between 7 and 10 and is very insensitive to Ca(2+ concentration. The enzyme is only distantly related to previously described cryophilic trypsins. We built and studied molecular structure models of this trypsin and performed molecular dynamic calculations. Key residues and structures associated with calcium dependency and cryophilicity were identified. Experiments indicated that the protein is unstable and susceptible to autoproteolysis. Correlating experimental results and structural predictions, we designed mutations to improve the resistance to autoproteolysis and conserve activity for longer periods after activation. One single mutation provided around 25 times more proteolytic stability. Due to its cryophilic nature, this trypsin is easily inactivated by mild denaturation conditions, which is ideal for controlled proteolysis processes without requiring inhibitors or dilution. We clearly show that cold adaptation, Ca(2+ dependency and autolytic stability in trypsins are related phenomena that are linked to shared structural features and evolve in a concerted fashion. Hence, both structurally and evolutionarily they cannot be interpreted and studied separately as previously done.

  19. HIGH-CURRENT COLD CATHODE FIELD EMISSION ARRAY FOR ELECTRON LENS APPLICATION

    Hirshfield, Jay L

    2012-12-28

    During Phase I, the following goals were achieved: (1) design and fabrication of a novel, nano-dimensional CNT field emitter assembly for high current density application, with high durability; (2) fabrication of a ceramic based micro channel plate (MCP) and characterization of its secondary electron emission; and (3) characterizing the CNT/MCP cathode for high field emission and durability. As a result of these achievements, a relatively high current density of ~ 1.2 A/cm2 from a CNT cathode and single channel MCP were measured. The emission current was also extremely stable with a peak-to-peak variation of only 1.8%. The emission current could be further enhanced to meet requirements for electron lens applications by increasing the number of MCP channels. A calculation for maximum possible current density with a 1200 channel/cm2 MCP, placed over a cathode with 1200 uniformly functioning CNTs, would be ~1.46 kA/cm2, neglecting space charge limitations. Clearly this level of emission is far greater than what is needed for the electron lens application, but it does offer a highly comforting margin to account for sub-standard emitters and/or to allow the lesser challenge of building a cathode with fewer channels/cm2. A satisfactory goal for the electron lens application would be a controllable emission of 2-4 mA per channel in an ensemble of 800-1200 uniformly-functioning channels/cm2, and a cathode with overall area of about 1 cm2.

  20. Cold injuries.

    Kruse, R J

    1995-01-01

    There are two categories of cold injury. The first is hypothermia, which is a systemic injury to cold, and the second is frostbite, which is a local injury. Throughout history, entire armies, from George Washington to the Germans on the Russian Front in World War II, have fallen prey to prolonged cold exposure. Cold injury is common and can occur in all seasons if ambient temperature is lower than the core body temperature. In the 1985 Boston Marathon, even though it was 76 degrees and sunny, there were 75 runners treated for hypothermia. In general, humans adapt poorly to cold exposure. Children are at particular risk because of their relatively greater surface area/body mass ratio, causing them to cool even more rapidly than adults. Because of this, the human's best defense against cold injury is to limit his/her exposure to cold and to dress appropriately. If cold injury has occurred and is mild, often simple passive rewarming such as dry blankets and a warm room are sufficient treatment.

  1. A closer look at the relationships between meridional mass circulation pulses in the stratosphere and cold air outbreak patterns in northern hemispheric winter

    Yu, Yueyue; Cai, Ming; Ren, Rongcai; Rao, Jian

    2018-01-01

    The relationship between continental-scale cold air outbreaks (CAOs) in the mid-latitudes and pulse signals in the stratospheric mass circulation in Northern Hemisphere winter (December-February) is investigated using ERA-Interim data for the 32 winters from 1979 to 2011. Pulse signals in the stratospheric mass circulation include "PULSE_TOT", "PULSE_W1", and "PULSE_W2" events, defined as a period of stronger meridional mass transport into the polar stratosphere by total flow, wavenumber-1, and wavenumber-2, respectively. Each type of PULSE event occurs on average 4-6 times per winter. A robust relationship is found between two dominant patterns of winter CAOs and PULSE_W1 and PULSE_W2 events. Cold temperature anomalies tend to occur over Eurasia with the other continent anomalously warm during the 2 weeks before the peak dates of PULSE_W1 events, while the opposite temperature anomaly pattern can be found after the peak dates; and during the 1-2 weeks centered on the peak dates of PULSE_W2 events, a higher probability of occurrence of CAOs is found over both continents. These relationships become more robust for PULSE_W1 and PULSE_W2 events of larger peak intensity. PULSE_TOT events are classified into five types, which have a distinct coupling relationship with PULSE_W1 and PULSE_W2 events. The specific pattern of CAOs associated with each type of PULSE_TOT event is found to be a combination of the CAO patterns associated with PULSE_W1 and PULSE_W2 events. The percentage of PULSE_TOT events belonging to the types that are dominated by PULSE_W2 events increases with the peak intensity of PULSE_TOT events. Accordingly, the related CAO pattern is close to that associated with PULSE_W1 for PULSE_TOT events with small-to-medium intensity, but tends to resemble that associated with PULSE_W2 events as the peak intensity of PULSE_TOT events increases.

  2. Development and Application of a Next Generation Air Sensor Network for the Hong Kong Marathon 2015 Air Quality Monitoring.

    Sun, Li; Wong, Ka Chun; Wei, Peng; Ye, Sheng; Huang, Hao; Yang, Fenhuan; Westerdahl, Dane; Louie, Peter K K; Luk, Connie W Y; Ning, Zhi

    2016-02-05

    This study presents the development and evaluation of a next generation air monitoring system with both laboratory and field tests. A multi-parameter algorithm was used to correct for the impact of environmental conditions on the electrochemical sensors for carbon monoxide (CO) and nitrogen dioxide (NO2) pollutants. The field evaluation in an urban roadside environment in comparison to designated monitors showed good agreement with measurement error within 5% of the pollutant concentrations. Multiple sets of the developed system were then deployed in the Hong Kong Marathon 2015 forming a sensor-based network along the marathon route. Real-time air pollution concentration data were wirelessly transmitted and the Air Quality Health Index (AQHI) for the Green Marathon was calculated, which were broadcast to the public on an hourly basis. The route-specific sensor network showed somewhat different pollutant patterns than routine air monitoring, indicating the immediate impact of traffic control during the marathon on the roadside air quality. The study is one of the first applications of a next generation sensor network in international sport events, and it demonstrated the usefulness of the emerging sensor-based air monitoring technology in rapid network deployment to supplement existing air monitoring.

  3. Development and Application of a Next Generation Air Sensor Network for the Hong Kong Marathon 2015 Air Quality Monitoring

    Li Sun

    2016-02-01

    Full Text Available This study presents the development and evaluation of a next generation air monitoring system with both laboratory and field tests. A multi-parameter algorithm was used to correct for the impact of environmental conditions on the electrochemical sensors for carbon monoxide (CO and nitrogen dioxide (NO2 pollutants. The field evaluation in an urban roadside environment in comparison to designated monitors showed good agreement with measurement error within 5% of the pollutant concentrations. Multiple sets of the developed system were then deployed in the Hong Kong Marathon 2015 forming a sensor-based network along the marathon route. Real-time air pollution concentration data were wirelessly transmitted and the Air Quality Health Index (AQHI for the Green Marathon was calculated, which were broadcast to the public on an hourly basis. The route-specific sensor network showed somewhat different pollutant patterns than routine air monitoring, indicating the immediate impact of traffic control during the marathon on the roadside air quality. The study is one of the first applications of a next generation sensor network in international sport events, and it demonstrated the usefulness of the emerging sensor-based air monitoring technology in rapid network deployment to supplement existing air monitoring.

  4. Development and Application of a Next Generation Air Sensor Network for the Hong Kong Marathon 2015 Air Quality Monitoring

    Sun, Li; Wong, Ka Chun; Wei, Peng; Ye, Sheng; Huang, Hao; Yang, Fenhuan; Westerdahl, Dane; Louie, Peter K.K.; Luk, Connie W.Y.; Ning, Zhi

    2016-01-01

    This study presents the development and evaluation of a next generation air monitoring system with both laboratory and field tests. A multi-parameter algorithm was used to correct for the impact of environmental conditions on the electrochemical sensors for carbon monoxide (CO) and nitrogen dioxide (NO2) pollutants. The field evaluation in an urban roadside environment in comparison to designated monitors showed good agreement with measurement error within 5% of the pollutant concentrations. Multiple sets of the developed system were then deployed in the Hong Kong Marathon 2015 forming a sensor-based network along the marathon route. Real-time air pollution concentration data were wirelessly transmitted and the Air Quality Health Index (AQHI) for the Green Marathon was calculated, which were broadcast to the public on an hourly basis. The route-specific sensor network showed somewhat different pollutant patterns than routine air monitoring, indicating the immediate impact of traffic control during the marathon on the roadside air quality. The study is one of the first applications of a next generation sensor network in international sport events, and it demonstrated the usefulness of the emerging sensor-based air monitoring technology in rapid network deployment to supplement existing air monitoring. PMID:26861336

  5. Cold rocks, hot sands: In-situ cosmogenic applications in Australia at ANTARES

    Fink, David; McKelvey, B.; Hannan, D.; Newsome, D.

    2000-01-01

    The ANTARES AMS facility at ANSTO is conducting a comprehensive program in the application of in-situ cosmogenic radionuclides based on strong university collaborations in the earth sciences. The program targets two major objectives: (1) to determine and improve the Quaternary glacial chronology of the Southern Hemisphere in support of global climate change studies; (2) to characterise the processes of surface weathering and landscape evolution in semi-arid regions of the Australian continent. An overview of the program is presented with preliminary results from the first phase of these studies

  6. Optimal design and application of a compound cold storage system combining seasonal ice storage and chilled water storage

    Yan, C.; Shi, W.; Li, X.; Zhao, Y.

    2016-01-01

    Seasonal cold storage using natural cold sources for cooling is a sustainable cooling technique. However, this technique suffers from limitations such as large storage space and poor reliability. Combining seasonal storage with short-term storage might be a promising solution while it is not

  7. Application of Parallel Algorithms in an Air Pollution Model

    Georgiev, K.; Zlatev, Z.

    1999-01-01

    Proceedings of the NATO Advanced Research Workshop on Large Scale Computations in Air Pollution Modelling, Sofia, Bulgaria, 6-10 July 1998......Proceedings of the NATO Advanced Research Workshop on Large Scale Computations in Air Pollution Modelling, Sofia, Bulgaria, 6-10 July 1998...

  8. Innovative application of air ejector as a pump for continuous air monitors

    Dhanasekaran, A.; Ajoy, K.C.; Santhanam, R.; Rajagopal, V.; Jose, M.T.

    2016-01-01

    Workplace monitoring, one of the key components of the radiation protection program is generally carried out by means of instruments installed permanently in respective areas or through portable air sampling instruments. Continuous air monitor (CAM) is one such monitor that constantly monitors the radionuclide concentration in air and triggers alarm as and when the air concentration goes above the pre-set levels. Conventional CAM system has a filter head, detector, display unit and a pump as four major parts. Pump may be either rotary vane or a vibrating diaphragm which are electrically driven using motors. Air lift pumps using ejectors are widely used where pump reliability and low maintenance are required, and where corrosive, abrasive, or radioactive fluids are handled. Since ejectors are uncomplicated alternative to vacuum pumps, an attempt was made to use the same as a pump for conventional CAMs. An ejector based sampling set up was made, tested and the results are represented in this paper

  9. Cold acclimation and cognitive performance: A review.

    Jones, Douglas M; Bailey, Stephen P; Roelands, Bart; Buono, Michael J; Meeusen, Romain

    2017-12-01

    Athletes, occupational workers, and military personnel experience cold temperatures through cold air exposure or cold water immersion, both of which impair cognitive performance. Prior work has shown that neurophysiological pathways may be sensitive to the effects of temperature acclimation and, therefore, cold acclimation may be a potential strategy to attenuate cold-induced cognitive impairments for populations that are frequently exposed to cold environments. This review provides an overview of studies that examine repeated cold stress, cold acclimation, and measurements of cognitive performance to determine whether or not cold acclimation provides beneficial protection against cold-induced cognitive performance decrements. Studies included in this review assessed cognitive measures of reaction time, attention, logical reasoning, information processing, and memory. Repeated cold stress, with or without evidence of cold acclimation, appears to offer no added benefit of improving cognitive performance. However, research in this area is greatly lacking and, therefore, it is difficult to draw any definitive conclusions regarding the use of cold acclimation to improve cognitive performance during subsequent cold exposures. Given the current state of minimal knowledge on this topic, athletes, occupational workers, and military commands looking to specifically enhance cognitive performance in cold environments would likely not be advised to spend the time and effort required to become acclimated to cold. However, as more knowledge becomes available in this area, recommendations may change. Copyright © 2017 Elsevier B.V. All rights reserved.

  10. The single-collision thermalization approximation for application to cold neutron moderation problems

    Ritenour, R.L.

    1989-01-01

    The single collision thermalization (SCT) approximation models the thermalization process by assuming that neutrons attain a thermalized distribution with only a single collision within the moderating material, independent of the neutron's incident energy. The physical intuition on which this approximation is based is that the salient properties of neutron thermalization are accounted for in the first collision, and the effects of subsequent collisions tend to average out statistically. The independence of the neutron incident and outscattering energy leads to variable separability in the scattering kernel and, thus, significant simplification of the neutron thermalization problem. The approximation also addresses detailed balance and neutron conservation concerns. All of the tests performed on the SCT approximation yielded excellent results. The significance of the SCT approximation is that it greatly simplifies thermalization calculations for CNS design. Preliminary investigations with cases involving strong absorbers also indicates that this approximation may have broader applicability, as in the upgrading of the thermalization codes

  11. APPLICATION OF NATURAL COLD FOR PROTECTION OF WATER RESOURCES AGAINST POLLUTION

    Alexander Sosnovskiy

    2012-01-01

    Full Text Available The paper presented herein discusses theoretical and practical aspects of formation artificial firn-ice masses and prospects for their use in solutions of practical and environmental problems. The method utilizes winter sprinkler irrigation with long-jet sprinklers. The mass of artificial firm can be as high as 10 meters. This application is effective for treatment and desalination to protect water resources from contamination. Mineralization of artificial firn is 5–10 times lower than the salinity of the original water. The dynamics of the removal of salts ions, microelements, and dissolved organic compounds during firn melting is assessed through mathematical modeling and experimental research. Melting of one-third of the firn mass decreases mineralization by more than a factor of 10.

  12. Study of Air Quality Health Index and its Application in Seven Cities of Iran in 2011

    Majid Kermani

    2017-03-01

    Full Text Available Abstract Background: Poor air quality has a lot of damage on the environment and humans. Awareness of the air quality situation reduces health effects of air pollution. This study was performed with the aim of the comparative investigation of Air Quality Health Index (AQHI and its application in seven major cities of Iran in 2011. Materials and Methods: This study was a descriptive–analytic one. First, the required data of four criteria pollutants were taken from Department of Environment in seven major cities of Iran. The data were validated by the World Health Organization criteria. The air quality health index was measured based on the instructions and classified into low, medium, high and very high degrees according to the air quality standard tables. Results: The results demonstrate that according to air quality health index, the level of air pollution in seven major cities of Iran has been undesirable and air quality has exceeded the standard level in Ahvaz 85%, Arak73%, Tehran70%, Esfahan60%, Shiraz 47%, Tabriz 43% and, Mashhad 29% of days. Conclusion: Due to poor air quality and health consequences resulting from it, importance of Air Quality Health Index is explored in planning to control and reduce air pollution and awareness of peoples from daily status of air quality and its health effects.

  13. Fabrication of Y-TZP For Dental Crowns Applications by Combining Slip Casting and Cold Isostatic Pressing

    Hao, C.C.; Andanastuti Muchtar; Che Husna Azhari; Masfueh Razali; Mohamed Aboras

    2016-01-01

    Yttria-stabilized tetragonal zirconia polycrystalline (Y-TZP) is a popular material for dental restoration because of its outstanding mechanical properties and biocompatibility. Cold isostatic pressing (CIP) and slip casting are among several consolidation methods for Y-TZP. These methods produce Y-TZP with high mechanical properties. This study aims to enhance the mechanical properties of Y-TZP by combining slip casting and CIP. Y-TZP samples were fabricated using CIP, slip casting, and their combination. Subsequently, the green bodies of the samples were sintered at 1600 degree Celcius. Their mechanical properties (density and hardness) were tested and their microstructures were scrutinized under a scanning electron microscope. Compared with the other two methods, the combined method significantly improved the mechanical properties of Y-TZP. In addition, the combined method also produced a compact and homogeneous microstructure. Therefore, the combination of slip casting and CIP is recommended in the production of Y-TZP with high mechanical properties for dental crown applications. (author)

  14. Development of an experimental radioisotope based process tomography system for research applications in a cold trickle bed column

    Sau, Madhusudan; Kumar, Pravesh; Kumar, Umesh; Acharya, Rajesh; Singh, Gursharan

    2009-01-01

    In chemical and petrochemical engineering applications, random and structured packing are used in process columns to enhance the heat and mass transfer between two phases. The packing used in such columns is meant to obtain a high specific interfacial area. It is of paramount importance for scale-up and design of trickle bed process columns, to understand and predict the complex multiphase fluid dynamics. In simplified terms, the phase holdup, solid packing distribution in terms of density and gas and liquid velocities among other important parameters need to be qualitatively and quantitatively understood. In the petrochemical industry, many processes are carried out using fixed bed reactors with concurrent upward and downward gas and liquid flows. In order to characterize the liquid and gas flow distribution through a mock-up column, data on planar and volume density distribution using computed tomographic measurements are very helpful. The paper describes the development efforts of a multi-detector 137 Cs radioisotope based in-situ tomography scanner suitable for 600mm dia. cold trickle bed reactor. The development work is at present in progress. The schematics and development of the scanner gantry is described in this paper. (author)

  15. Evaluation of a fast power demand response strategy using active and passive building cold storages for smart grid applications

    Cui, Borui; Wang, Shengwei; Yan, Chengchu; Xue, Xue

    2015-01-01

    Highlights: • A fast power demand response strategy is developed for smart grid applications. • The developed strategy can provide immediate and stepped power demand reduction. • The demand reduction and building indoor temperature can be predicted accurately. • The demand reduction during the DR event is stable. - Abstract: Smart grid is considered as a promising solution in improving the power reliability and sustainability where demand response is one important ingredient. Demand response (DR) is a set of demand-side activities to reduce or shift electricity use to improve the electric grid efficiency and reliability. This paper presents the investigations on the power demand alternation potential for buildings involving both active and passive cold storages to support the demand response of buildings connected to smart grids. A control strategy is developed to provide immediate and stepped power demand reduction through shutting chiller(s) down when requested. The primary control objective of the developed control strategy is to restrain the building indoor temperature rise as to maintain indoor thermal comfort within certain level during the DR event. The chiller power reduction is also controlled under certain power reduction set-point. The results show that stepped and significant power reduction can be achieved through shutting chiller(s) down when requested. The power demand reduction and indoor temperature during the DR event can be also predicted accurately. The power demand reduction is stable which is predictable for the system operators

  16. Application Waste Sawdust as Mixed Polyurethane Insulation in Traditional Cold Storage of Fishing Vessel

    Sutopo Purwono Fitri

    2017-03-01

    Full Text Available In the process of fishing it takes some supplies such as fishing equipment, instrumentation and storage of fish. The traditional fishermen of their fishing days fishing usually only bring ice cubes. Solid plastic polyurethane foam is a mixture solution of polyols and isocyanates, commonly used as an insulating material storage. From the observation waste generated being sawmill sawdust per spindle with diameter of 30 cm and a length of 1 m with 5 times sawmill, Saws 0.8 cm thick produced 0.0088 m³ / burnable logs only discarded. Therefore takes thermal conductivity test to review mixture of sawdust and polyurethane comparison with variations different dosing. Maximum disposals sawdust can be done is 40% of the total volume of material mixture, polyurethane and sawdust because composite material (sawdust-polyurethane can not be bond with good so easy slab separately from origin form. Thermal Conductivity insulating good and economical on disposals 40% wood flour (0.05252 W / m°C and is able to maintain a 2 kg of ice crystals melt up perfect on 34 hours. Operating profits economical from 4,8 m³insulation composite application with obtained Rp 4.486.000 compared with 100% Polyurethane Insulation Manufacture.

  17. MEMS Coupled Resonator for Filter Application in Air

    Ilyas, Saad; Jaber, Nizar; Younis, Mohammad I.

    2017-01-01

    We present a mechanically coupled MEMS H resonator capable of performing simultaneous amplification and filter operation in air. The device comprises of two doubly clamped polyimide microbeams joined through the middle by a coupling beam of the same size. The resonator is fabricated via a multilayer surface micromachining process. A special fabrication process and device design is employed to enable the device's operation in air and to achieve mechanical amplification of the output response. Moreover, mixed-frequency excitation is used to demonstrate a tunable wide band filter. The device design combined with the mixed-frequency excitation is used to demonstrate simultaneous amplification and filtering in air.

  18. MEMS Coupled Resonator for Filter Application in Air

    Ilyas, Saad

    2017-11-03

    We present a mechanically coupled MEMS H resonator capable of performing simultaneous amplification and filter operation in air. The device comprises of two doubly clamped polyimide microbeams joined through the middle by a coupling beam of the same size. The resonator is fabricated via a multilayer surface micromachining process. A special fabrication process and device design is employed to enable the device\\'s operation in air and to achieve mechanical amplification of the output response. Moreover, mixed-frequency excitation is used to demonstrate a tunable wide band filter. The device design combined with the mixed-frequency excitation is used to demonstrate simultaneous amplification and filtering in air.

  19. The application of cold-plasma coagulation on the visceral pleura results in a predictable depth of necrosis without fistula generation

    Hoffmann, Martin; Ulrich, Anita; Schloericke, Erik; Limmer, Stefan; Habermann, Jens Karsten; Wolken, Heike; Bruch, Hans-Peter; Kujath, Peter

    2012-01-01

    A technique for the safe transfer of electric energy to the pulmonary surface for the potential evaporation of malignant tumours is non-existent to date. By conducting the current study, we wanted to generate data on the potential beneficiary effects and complications of using cold-plasma coagulation on the pulmonary surface. Cold-plasma coagulation was applied to the pulmonary surface in eight female mini-pigs via a thoracoscopic access. After 12 days, we performed a re-thoracoscopy on the contralateral side. After a further 12 days, we performed a median sternotomy and did cold-plasma coagulation on previously untreated areas of either lung. No pulmonary fistulas were detected. In two of the eight pigs, we found a localized chronic pneumonia. None of the pigs died during the course of the study. Morbidity was also low with two pigs refusing food intake, one pig with dyspnoea after difficult intubation and one pig coughing. All events were self-limited and occurred only on post-operative Day 1. The treatment effect was almost linear and correlated to the generator energy applied. The differences between the effects reached statistical significance (P < 0.05). The application of cold-plasma coagulation to the pulmonary surface is safe in pigs. A potential clinical application of this technique is treatment of malignant pleural mesothelioma. PMID:22194274

  20. Dynamic light scattering study on phase separation of a protein-water mixture: Application on cold cataract development in the ocular lens

    Petta, V.; Pharmakakis, N.; Papatheodorou, G. N.; Yannopoulos, S. N.

    2008-06-01

    We present a detailed dynamic light scattering study of the phase separation in the ocular lens emerging during cold cataract development. Cold cataract is a phase separation effect that proceeds via spinodal decomposition of the lens cytoplasm with cooling. The intensity autocorrelation functions of the lens protein content are analyzed with the aid of two methods, providing information on the populations and dynamics of the scattering elements associated with cold cataract. It is found that the temperature dependence of many measurable parameters changes appreciably at the characteristic temperature ˜16±1°C which is associated with the onset of cold cataract. By extending the temperature range of this work to previously inaccessible regimes, i.e., well below the phase separation or coexistence curve at Tcc , we have been able to accurately determine the temperature dependence of the collective and self-diffusion coefficients of proteins near the spinodal. The analysis showed that the dynamics of proteins bears some resemblance to the dynamics of structural glasses, where the apparent activation energy for particle diffusion increases below Tcc , indicating a highly cooperative motion. Application of ideas developed for studying the critical dynamics of binary protein-solvent mixtures, as well as the use of a modified Arrhenius equation, enabled us to estimate the spinodal temperature Tsp of the lens nucleus. The applicability of dynamic light scattering as a noninvasive, early-diagnostic tool for ocular diseases is also demonstrated in light of the findings of the present paper.

  1. Antimicrobial and antioxidant potentials of biosynthesized colloidal zinc oxide nanoparticles for a fortified cold cream formulation: A potent nanocosmeceutical application.

    S, Sonia; H, Linda Jeeva Kumari; K, Ruckmani; M, Sivakumar

    2017-10-01

    Nanocosmeceuticals are promising applications of nanotechnology in personal care industries. Zinc oxide is an inorganic material that is non-toxic and skin compatible with self-cleansing and microbicidal properties. Herein, exploitation of colloidal zinc oxide nanoparticles (ZnONps) as potent biomaterial for a topical formulation of cosmetic and dermatological significance is employed. ZnONps were green synthesized using environmentally benign Adhatoda vasica leaf extract and characterized by UV-Vis absorption spectroscopy, Fourier transform infrared spectroscopy (FTIR), X-ray diffraction (XRD), dynamic light scattering (DLS), high-resolution transmission electron microscopy (HR-TEM) and energy-dispersive X-ray spectroscopy (EDX). The results reveal that the biosynthesized ZnONps exhibit an absorption peak at 352nm. XRD and HR-TEM analyses confirm the hexagonal wurtzite structure of ZnONps with particle size of about 10nm to 12nm. Elemental analysis by EDX confirms the presence of zinc and oxygen. Zeta potential of -24.6mV affirms the stability of nanoparticles. The antibacterial and antifungal activities of biosynthesized ZnONps exhibit mean zone of inhibition from 08.667±0.282 to 21.666±0.447 (mm) and 09.000±0.177 to 19.000±0.307 (mm) respectively, in a dose-dependent manner. The IC 50 value exerted from the antioxidant activity of ZnONps is found to be 139.27μgmL -1 . ZnONps infused cold cream formulation of microbicidal and antioxidant properties was further tested against clinical skin pathogens. The nano-based cold cream exhibited significant inhibitory action against Candida sp., which showed resistance against a commercial antifungal cream (2%). Therefore, this study demonstrates the exploitation of ZnONps as promising colloidal drug carriers in cosmeceuticals that can significantly alleviate human skin infections and oxidative stress induced cellular damage. Copyright © 2017 Elsevier B.V. All rights reserved.

  2. Subcutaneous and Intramuscular Hemodynamics and Oxygenation After Cold-Spray Application as Monitored by Near-Infrared Spectroscopy

    Shadgan, Babak; Pakravan, Amir H.; Hoens, Alison; Reid, W. Darlene

    2015-01-01

    Context Vapocoolant spray, commonly known as cold spray (CS), is a cryotherapy modality used in sports medicine, athletic training, and rehabilitation settings. Proposed physiologic effects of cryotherapy modalities include reductions in tissue blood flow, oxygenation, and cell metabolism in addition to attenuation of pain perception attributed to reduced superficial nerve conduction velocity. Objective To examine the effects of CS on subcutaneous and intramuscular blood flow and oxygenation on the thigh muscle using near-infrared spectroscopy, an optical method to monitor changes in tissue oxygenated (O2Hb), deoxygenated (HHb), and total (tHb) hemoglobin. Design Cross-sectional study. Setting Muscle Biophysics Laboratory. Patients or Other Participants Participants were 13 healthy adults (8 men, 5 women; age = 37.4 ± 6 years, body mass index = 27.4 ± 2.6, adipose tissue thickness = 7.2 ± 1.8 mm). Intervention(s) Conventional CS was applied to the vastus medialis muscles. Main Outcome Measure(s) Changes in chromophore concentrations of O2Hb, HHb, and tHb at superficial and deep layers were monitored for 5 minutes using a 2-channel near-infrared spectroscopy. Results Thirty seconds after CS application, we observed a decrease from baseline in O2Hb and tHb only in the superficial layer that was maintained for 3 minutes. Conclusions Application of CS induced a transient change in blood flow and oxygenation of the superficial tissues with no change in deeper tissues over the healthy vastus medialis muscle. The limited physiologic effect of CS on the superficial hemodynamics and oxygenation of limb muscles may limit the therapeutic benefit of this cryotherapy modality to a temporary analgesic effect, a hypothesis that warrants a clinical trial on traumatized muscles. PMID:26098273

  3. Feedback linearization based control of a variable air volume air conditioning system for cooling applications.

    Thosar, Archana; Patra, Amit; Bhattacharyya, Souvik

    2008-07-01

    Design of a nonlinear control system for a Variable Air Volume Air Conditioning (VAVAC) plant through feedback linearization is presented in this article. VAVAC systems attempt to reduce building energy consumption while maintaining the primary role of air conditioning. The temperature of the space is maintained at a constant level by establishing a balance between the cooling load generated in the space and the air supply delivered to meet the load. The dynamic model of a VAVAC plant is derived and formulated as a MIMO bilinear system. Feedback linearization is applied for decoupling and linearization of the nonlinear model. Simulation results for a laboratory scale plant are presented to demonstrate the potential of keeping comfort and maintaining energy optimal performance by this methodology. Results obtained with a conventional PI controller and a feedback linearizing controller are compared and the superiority of the proposed approach is clearly established.

  4. Cold Sore

    ... may reduce how often they return. Symptoms A cold sore usually passes through several stages: Tingling and itching. Many people feel an itching, burning or tingling sensation around their lips for a day or so ...

  5. An Application of the Methodology for Assessment of the Sustainability of Air Transport System

    Janic, Milan

    2003-01-01

    An assessment and operationalization of the concept of sustainable air transport system is recognized as an important but complex research, operational and policy task. In the scope of the academic efforts to properly address the problem, this paper aims to assess the sustainability of air transport system. It particular, the paper describes the methodology for assessment of sustainability and its potential application. The methodology consists of the indicator systems, which relate to the air transport system operational, economic, social and environmental dimension of performance. The particular indicator systems are relevant for the particular actors such users (air travellers), air transport operators, aerospace manufacturers, local communities, governmental authorities at different levels (local, national, international), international air transport associations, pressure groups and public. In the scope of application of the methodology, the specific cases are selected to estimate the particular indicators, and thus to assess the system sustainability under given conditions.

  6. Application of air ions for bacterial de-colonization in air filters contaminated by aerosolized bacteria

    Kim, Yang Seon; Yoon, Ki Young; Park, Jae Hong; Hwang, Jungho

    2011-01-01

    We aerosolized the Escherichia coli (E. coli) and Staphylococcus epidermidis (S. epidermidis) bacteria and collected them on membrane filters. Then we generated air ions by applying a high voltage to a carbon fiber tip and applied them to the contaminated filters. The antibacterial efficiency was not significantly affected by the bacteria being Gram-positive or Gram-negative, however, negative ions showed a lower antibacterial efficiency than positive ions to both E. coli and S. epidermidis, even though the concentration of negative air ions was much higher than that of positive air ions. With a field emission scanning electron microscope (FE-SEM) images and fluorescence microscopy images using a LIVE/DEAD BacLight Bacterial Viability Kit, electrostatic disruption of the bacteria was found to be the dominant antibacterial effect. - Research Highlights: →This study examined the effects of air ions generated by a carbon fiber ionizer on the inactivation of bioaerosols. →When the ion exposure time and the ion generation concentration were increased, the antibacterial efficiency increased. →The bioaerosols carried a significant number of negative electrical charges. →Negative ions showed lower antibacterial efficiency than positive ions to both E. coli and S. epidermidis, even though the concentration of negative air ions was much higher than that of positive air ions.

  7. A Summary of OMI NO2 Data for Air Quality Applications

    Duncan, Bryan N.; Lamsal, Lok N.; Yoshida, Yasuko; Thompson, Anne M.

    2016-01-01

    As a member of NASA's Air Quality Applied Sciences Team (AQAST), I will update air quality managers on the status of various NASA satellite datasets that are relevant for air quality applications. I will also present a new website that contains NASA Aura OMI nitrogen dioxide data and shows US city trends and comparisons to EPA surface monitor data. Since this is the final AQAST meeting, I will summarize my contributions to AQAST over the last five years.

  8. Cold source economic study

    Fuster, Serge.

    1975-01-01

    This computer code is intended for the statement of the general economic balance resulting from using a given cold source. The balance includes the investments needed for constructing the various materials, and also production balances resulting from their utilization. The case of either using an open circuit condenser on sea or river, or using air cooling systems with closed circuits or as auxiliaries can be dealt with. The program can be used to optimize the characteristics of the various parts of the cold source. The performance of the various materials can be evaluated for a given situation from using very full, precise economic balances, these materials can also be classified according to their possible uses, the outer constraints being taken into account (limits for heat disposal into rivers or seas, water temperature, air temperature). Technical choices whose economic consequences are important have been such clarified [fr

  9. The development and application of a cold atmospheric plasma generator for treatment of skin and soft-tissue injuries in animals

    Emelyanov, O. A.; Petrova, N. O.; Smirnova, N. V.; Shemet, M. V.

    2017-08-01

    We describe a device for obtaining cold plasma in air at atmospheric pressure using a system of positive high-voltage pin electrodes, which is intended for the treatment of skin and soft-tissue injuries in animals. Plasma is generated due to the development of periodic pulsed discharge of nanosecond duration at current pulse amplitudes 10-20 mA, characteristic frequencies 10-20 kHz, and applied voltages within 8-10 kV. The high efficacy of the proposed device and method is confirmed by the good clinical results of treating large domestic animals with traumatic injuries.

  10. 77 FR 27833 - Notice of Applications for Certificates of Public Convenience and Necessity and Foreign Air...

    2012-05-11

    ... DEPARTMENT OF TRANSPORTATION Office of the Secretary Notice of Applications for Certificates of Public Convenience and Necessity and Foreign Air Carrier Permits Filed Under Subpart B (Formerly Subpart... Convenience and Necessity and Foreign Air Carrier Permits were filed under Subpart B (formerly Subpart Q) of...

  11. 76 FR 10084 - Notice of Applications for Certificates of Public Convenience and Necessity and Foreign Air...

    2011-02-23

    ... DEPARTMENT OF TRANSPORTATION Office of the Secretary Notice of Applications for Certificates of Public Convenience and Necessity and Foreign Air Carrier Permits Filed Under Subpart B (Formerly Subpart... Convenience and Necessity and Foreign Air Carrier Permits were filed under Subpart B (formerly Subpart Q) of...

  12. 76 FR 72025 - Notice of Applications for Certificates of Public Convenience and Necessity and Foreign Air...

    2011-11-21

    ... DEPARTMENT OF TRANSPORTATION Office of the Secretary Notice of Applications for Certificates of Public Convenience and Necessity and Foreign Air Carrier Permits Filed Under Subpart B (Formerly Subpart... Convenience and Necessity and Foreign Air Carrier Permits were filed under Subpart B (formerly Subpart Q) of...

  13. 77 FR 37732 - Notice of Applications for Certificates of Public Convenience and Necessity and Foreign Air...

    2012-06-22

    ... DEPARTMENT OF TRANSPORTATION Office of the Secretary Notice of Applications for Certificates of Public Convenience and Necessity and Foreign Air Carrier Permits Filed Under Subpart B (Formerly Subpart... Convenience and Necessity and Foreign Air Carrier Permits were filed under Subpart B (formerly Subpart Q) of...

  14. 77 FR 47691 - Notice of Applications for Certificates of Public Convenience and Necessity and Foreign Air...

    2012-08-09

    ... DEPARTMENT OF TRANSPORTATION Office of the Secretary Notice of Applications for Certificates of Public Convenience and Necessity and Foreign Air Carrier Permits Filed Under Subpart B (Formerly Subpart... Convenience and Necessity and Foreign Air Carrier Permits were filed under Subpart B (formerly Subpart Q) of...

  15. 77 FR 59243 - Notice of Applications for Certificates of Public Convenience and Necessity and Foreign Air...

    2012-09-26

    ... DEPARTMENT OF TRANSPORTATION Office of the Secretary Notice of Applications for Certificates of Public Convenience and Necessity and Foreign Air Carrier Permits Filed Under Subpart B (Formerly Subpart... Convenience and Necessity and Foreign Air Carrier Permits were filed under Subpart B (formerly Subpart Q) of...

  16. 76 FR 33400 - Notice of Applications for Certificates of Public Convenience and Necessity and Foreign Air...

    2011-06-08

    ... DEPARTMENT OF TRANSPORTATION Office of the Secretary Notice of Applications for Certificates of Public Convenience and Necessity and Foreign Air Carrier Permits Filed Under Subpart B (formerly Subpart... Convenience and Necessity and Foreign Air Carrier Permits were filed under Subpart B (formerly Subpart Q) of...

  17. 77 FR 67731 - Notice of Applications for Certificates of Public Convenience and Necessity and Foreign Air...

    2012-11-13

    ... DEPARTMENT OF TRANSPORTATION Office of the Secretary Notice of Applications for Certificates of Public Convenience and Necessity and Foreign Air Carrier Permits Filed Under Subpart B (Formerly Subpart... Convenience and Necessity and Foreign Air Carrier Permits were filed under Subpart B (formerly Subpart Q) of...

  18. 76 FR 42762 - Notice of Applications for Certificates of Public Convenience and Necessity and Foreign Air...

    2011-07-19

    ... DEPARTMENT OF TRANSPORTATION Office of the Secretary Notice of Applications for Certificates of Public Convenience and Necessity and Foreign Air Carrier Permits Filed Under Subpart B (formerly Subpart... Convenience and Necessity and Foreign Air Carrier Permits were filed under Subpart B (formerly Subpart Q) of...

  19. 76 FR 13444 - Notice of Applications for Certificates of Public Convenience and Necessity and Foreign Air...

    2011-03-11

    ... DEPARTMENT OF TRANSPORTATION Office of the Secretary Notice of Applications for Certificates of Public Convenience and Necessity and Foreign Air Carrier Permits Filed Under Subpart B (Formerly Subpart... Convenience and Necessity and Foreign Air Carrier Permits were filed under Subpart B (formerly Subpart Q) of...

  20. 77 FR 13682 - Notice of Applications for Certificates of Public Convenience and Necessity and Foreign Air...

    2012-03-07

    ... DEPARTMENT OF TRANSPORTATION Office of the Secretary Notice of Applications for Certificates of Public Convenience and Necessity and Foreign Air Carrier Permits Filed Under Subpart B (Formerly Subpart... Convenience and Necessity and Foreign Air Carrier Permits were filed under Subpart B (formerly Subpart Q) of...

  1. 76 FR 70210 - Notice of Applications for Certificates of Public Convenience and Necessity and Foreign Air...

    2011-11-10

    ... DEPARTMENT OF TRANSPORTATION Office of the Secretary Notice of Applications for Certificates of Public Convenience and Necessity and Foreign Air Carrier Permits Filed Under Subpart B (Formerly Subpart... Convenience and Necessity and Foreign Air Carrier Permits were filed under Subpart B (formerly Subpart Q) of...

  2. 76 FR 20434 - Notice of Applications for Certificates of Public Convenience and Necessity and Foreign Air...

    2011-04-12

    ... DEPARTMENT OF TRANSPORTATION Office of the Secretary Notice of Applications for Certificates of Public Convenience and Necessity and Foreign Air Carrier Permits Filed Under Subpart B (Formerly Subpart... Convenience and Necessity and Foreign Air Carrier Permits were filed under subpart B (formerly subpart Q) of...

  3. 78 FR 56984 - Notice of Applications for Certificates of Public Convenience and Necessity and Foreign Air...

    2013-09-16

    ... DEPARTMENT OF TRANSPORTATION Office of the Secretary Notice of Applications for Certificates of Public Convenience and Necessity and Foreign Air Carrier Permits Filed Under Subpart B (formerly Subpart... Convenience and Necessity and Foreign Air Carrier Permits were filed under Subpart B (formerly Subpart Q) of...

  4. 76 FR 68257 - Notice of Applications for Certificates of Public Convenience and Necessity and Foreign Air...

    2011-11-03

    ... DEPARTMENT OF TRANSPORTATION Office of the Secretary Notice of Applications for Certificates of Public Convenience and Necessity and Foreign Air Carrier Permits Filed Under Subpart B (Formerly Subpart... Convenience and Necessity and Foreign Air Carrier Permits were filed under Subpart B (formerly Subpart Q) of...

  5. 77 FR 39793 - Notice of Applications for Certificates of Public Convenience and Necessity and Foreign Air...

    2012-07-05

    ... DEPARTMENT OF TRANSPORTATION Office of the Secretary Notice of Applications for Certificates of Public Convenience and Necessity and Foreign Air Carrier Permits Filed Under Subpart B (Formerly Subpart... Convenience and Necessity and Foreign Air Carrier Permits were filed under Subpart B (formerly Subpart Q) of...

  6. 77 FR 49478 - Notice of Applications for Certificates of Public Convenience and Necessity and Foreign Air...

    2012-08-16

    ... Public Convenience and Necessity and Foreign Air Carrier Permits Filed Under Subpart B (Formerly Subpart... Convenience and Necessity and Foreign Air Carrier Permits were filed under Subpart B (formerly Subpart Q) of... Application of Rhoades Aviation, Inc. d/b/a Transair requesting a certificate of public convenience and...

  7. 77 FR 70208 - Notice of Applications for Certificates of Public Convenience and Necessity and Foreign Air...

    2012-11-23

    ... DEPARTMENT OF TRANSPORTATION Office of the Secretary Notice of Applications for Certificates of Public Convenience and Necessity and Foreign Air Carrier Permits Filed Under Subpart B (Formerly Subpart... Convenience and Necessity and Foreign Air Carrier Permits were filed under Subpart B (formerly Subpart Q) of...

  8. 76 FR 35939 - Notice of Applications for Certificates of Public Convenience and Necessity and Foreign Air...

    2011-06-20

    ... DEPARTMENT OF TRANSPORTATION Office of the Secretary Notice of Applications for Certificates of Public Convenience and Necessity and Foreign Air Carrier Permits Filed Under Subpart B (Formerly Subpart... Convenience and Necessity and Foreign Air Carrier Permits were filed under Subpart B (formerly Subpart Q) of...

  9. 76 FR 51458 - Notice of Applications for Certificates of Public Convenience and Necessity and Foreign Air...

    2011-08-18

    ... DEPARTMENT OF TRANSPORTATION Office of the Secretary Notice of Applications for Certificates of Public Convenience and Necessity and Foreign Air Carrier Permits Filed Under Subpart B (Formerly Subpart... Convenience and Necessity and Foreign Air Carrier Permits were filed under subpart B (formerly subpart Q) of...

  10. 76 FR 27167 - Notice of Applications for Certificates of Public Convenience and Necessity and Foreign Air...

    2011-05-10

    ... DEPARTMENT OF TRANSPORTATION Office of the Secretary Notice of Applications for Certificates of Public Convenience and Necessity and Foreign Air Carrier Permits Filed Under Subpart B (Formerly Subpart... Convenience and Necessity and Foreign Air Carrier Permits were filed under Subpart B (formerly Subpart Q) of...

  11. 76 FR 35938 - Notice of Applications for Certificates of Public Convenience and Necessity and Foreign Air...

    2011-06-20

    ... DEPARTMENT OF TRANSPORTATION Office of the Secretary Notice of Applications for Certificates of Public Convenience and Necessity and Foreign Air Carrier Permits Filed Under Subpart B (Formerly Subpart... Convenience and Necessity and Foreign Air Carrier Permits were filed under Subpart B (formerly Subpart Q) of...

  12. 75 FR 60491 - Notice of Applications for Certificates of Public Convenience and Necessity and Foreign Air...

    2010-09-30

    ... DEPARTMENT OF TRANSPORTATION Office of the Secretary Notice of Applications for Certificates of Public Convenience and Necessity and Foreign Air Carrier Permits Filed Under Subpart B (Formerly Subpart... Convenience and Necessity and Foreign Air Carrier Permits were filed under Subpart B (formerly Subpart Q) of...

  13. 77 FR 31421 - Notice of Applications for Certificates of Public Convenience and Necessity and Foreign Air...

    2012-05-25

    ... DEPARTMENT OF TRANSPORTATION Office of the Secretary Notice of Applications for Certificates of Public Convenience and Necessity and Foreign Air Carrier Permits Filed Under Subpart B (Formerly Subpart... Convenience and Necessity and Foreign Air Carrier Permits were filed under Subpart B (formerly Subpart Q) of...

  14. 77 FR 46146 - Notice of Applications for Certificates of Public Convenience and Necessity and Foreign Air...

    2012-08-02

    ... DEPARTMENT OF TRANSPORTATION Office of the Secretary Notice of Applications for Certificates of Public Convenience and Necessity and Foreign Air Carrier Permits Filed Under Subpart B (Formerly Subpart... Convenience and Necessity and Foreign Air Carrier Permits were filed under Subpart B (formerly Subpart Q) of...

  15. 77 FR 27832 - Notice of Applications for Certificates of Public Convenience and Necessity and Foreign Air...

    2012-05-11

    ... DEPARTMENT OF TRANSPORTATION Office of the Secretary Notice of Applications for Certificates of Public Convenience and Necessity and Foreign Air Carrier Permits Filed Under Subpart B (Formerly Subpart... Convenience and Necessity and Foreign Air Carrier Permits were filed under Subpart B (formerly Subpart Q) of...

  16. 78 FR 5854 - Application of Scott Air, LLC for Certificate Authority

    2013-01-28

    ... DEPARTMENT OF TRANSPORTATION Office of the Secretary Application of Scott Air, LLC for Certificate Authority AGENCY: Department of Transportation. ACTION: Notice of order to show cause (Order 2013-1-12... to show cause why it should not issue an order finding Scott Air, LLC fit, willing, and able, and...

  17. A WEB API AND WEB APPLICATION DEVELOPMENT FOR DISSEMINATION OF AIR QUALITY INFORMATION

    K. Şahin

    2017-11-01

    Full Text Available Various studies have been carried out since 2005 under the leadership of Ministry of Environment and Urbanism of Turkey, in order to observe the quality of air in Turkey, to develop new policies and to develop a sustainable air quality management strategy. For this reason, a national air quality monitoring network has been developed providing air quality indices. By this network, the quality of the air has been continuously monitored and an important information system has been constructed in order to take precautions for preventing a dangerous situation. The biggest handicap in the network is the data access problem for instant and time series data acquisition and processing because of its proprietary structure. Currently, there is no service offered by the current air quality monitoring system for exchanging information with third party applications. Within the context of this work, a web service has been developed to enable location based querying of the current/past air quality data in Turkey. This web service is equipped with up-todate and widely preferred technologies. In other words, an architecture is chosen in which applications can easily integrate. In the second phase of the study, a web-based application was developed to test the developed web service and this testing application can perform location based acquisition of air-quality data. This makes it possible to easily carry out operations such as screening and examination of the area in the given time-frame which cannot be done with the national monitoring network.

  18. a Web Api and Web Application Development for Dissemination of Air Quality Information

    Şahin, K.; Işıkdağ, U.

    2017-11-01

    Various studies have been carried out since 2005 under the leadership of Ministry of Environment and Urbanism of Turkey, in order to observe the quality of air in Turkey, to develop new policies and to develop a sustainable air quality management strategy. For this reason, a national air quality monitoring network has been developed providing air quality indices. By this network, the quality of the air has been continuously monitored and an important information system has been constructed in order to take precautions for preventing a dangerous situation. The biggest handicap in the network is the data access problem for instant and time series data acquisition and processing because of its proprietary structure. Currently, there is no service offered by the current air quality monitoring system for exchanging information with third party applications. Within the context of this work, a web service has been developed to enable location based querying of the current/past air quality data in Turkey. This web service is equipped with up-todate and widely preferred technologies. In other words, an architecture is chosen in which applications can easily integrate. In the second phase of the study, a web-based application was developed to test the developed web service and this testing application can perform location based acquisition of air-quality data. This makes it possible to easily carry out operations such as screening and examination of the area in the given time-frame which cannot be done with the national monitoring network.

  19. Scientific and Technological Principles of Development of New Cold-Resistant Arc-Steels (Steels for Arctic Applications)

    Sych, O. V.; Khlusova, E. I.; Yashin, E. A.

    2017-12-01

    The paper presents the results of quantitative analysis of C, Mn, Ni and Cu content on strength and cold-resistance of rolled plates. Relations between the ferritic-bainitic structure morphology and anisotropy and steel performance characteristics have been established. Influence of thermal and deformation rolling patterns on steel structure has been studied. The steel chemical composition has been improved and precision thermomechanical processing conditions for production of cold-resistant Arc-steel plates have been developed.

  20. Application of ground-to-air heat exchanger for preheating of supply air

    Sorokins, Juris; Borodinecs, Anatolijs; Zemitis, Jurgis

    2017-10-01

    This study focuses on assessing the contribution of the passive ground-coupled air heat exchanger system to decreasing the energy consumption of air conditioning and ventilation systems for office buildings in the Latvian climate conditions. The theoretical part of the thesis deals with methods of office building ventilation, supply air preheating and heat recovery as well as particularities of using ground-coupled air heat exchangers, their design parameters and their joint impact on the thermal performance. The engineering project part includes a ventilation system for an office building with an integrated ground-coupled air heat exchanger. By simulating energy consumption of the ventilation system for a duration of one year, the thesis analyzes the contribution of the heat exchanger to the overall energy consumption, which totals 9.53 MWh and 4.02 MWh a year, according to the desired parameters of the indoor climate. The possible alternative heat recovery solutions are investigated to reach by European Regional Development Fund project Nr.1.1.1.1/16/A/048 “NEARLY ZERO ENERGY SOLUTIONS FOR UNCLASSIFIED BUILDINGS”.

  1. NASA Earth Observation Systems and Applications for Health and Air Quality

    Omar, Ali H.

    2015-01-01

    There is a growing body of evidence that the environment can affect human health in ways that are both complex and global in scope. To address some of these complexities, NASA maintains a diverse constellation of Earth observing research satellites, and sponsors research in developing satellite data applications across a wide spectrum of areas. These include environmental health; infectious disease; air quality standards, policies, and regulations; and the impact of climate change on health and air quality in a number of interrelated efforts. The Health and Air Quality Applications fosters the use of observations, modeling systems, forecast development, application integration, and the research to operations transition process to address environmental health effects. NASA has been a primary partner with Federal operational agencies over the past nine years in these areas. This talk presents the background of the Health and Air Quality Applications program, recent accomplishments, and a plan for the future.

  2. The ‘full sleeve’ application in the horizontal cold-chamber machine for pressure die casting of aluminium alloys

    Z. Konopka

    2008-04-01

    Full Text Available The ‘full sleeve’ construction has been designed and accomplished in the horizontal cold-chamber pressure die casting machine. Main part of this solution is a counter plunger placed in a movable die half which allows for full filling of the shot sleeve and precisely fixes the metal quantity needed for casting. The purpose of this new construction solution is mainly the reduction of the casting porosity caused by air entrapment and the improvement of both castability and accuracy of the die cavity reproduction. For such a redesigned machine there have been performed examinations consisting in pressure casting of AlSi9Cu alloy (EN AC-46000 at varying plunger velocity in the second stage of injection and varying intensification pressure. The alloy castability (the die filling ability has been measured for each parameter setting. For the purpose of comparison, similar measurements have been performed also for the conventional system without a counter plunger. The castability examination has been done by means of a specially designed die with an impression of a trial casting of variable wall thickness. The experiments have been held according to the assumed factor design 22, what allowed for determining the mathematical models describing the influence of die filling parameters on the castability and the die cavity reproduction level. Both alternatives of the experiment confirmed the positive influence of plunger velocity and intensification pressure increase on the improvement of castability, the measure of the latter being the filled length of the impression. Applying of the new ‘full sleeve’ solution has improved castability for each experiment by about 20% as compared with conventional alternative. Castability in the ‘full sleeve’ system has been increased even for low values of plunger velocity and intensification pressure. For both alternative systems the influence of plunger velocity has been found, as an average, by four times

  3. Application of propagation calculations in air quality control

    Kuelske, S.

    1993-01-01

    This paper describes the development of a methodics of propagation calculation since the foundation of the 'Landesanstalt fuer Immissionsschutz' in 1963, and its practical use in air quality control. In this context, it deals with methods for calculating stack heights and the Gaussian propagation model adopted by the Technical Code on Clean Air, the propagation of flue gas emitted via cooling towers, the propagation of accidentally released substances, odours and automobile emissions, and with flow and propagation calculation for the proximity zone of buildings as well as for meteorological fields with space and time variations and topographically varied terrain. (orig.) [de

  4. Model-generated air quality statistics for application in vegetation response models in Alberta

    McVehil, G.E.; Nosal, M.

    1990-01-01

    To test and apply vegetation response models in Alberta, air pollution statistics representative of various parts of the Province are required. At this time, air quality monitoring data of the requisite accuracy and time resolution are not available for most parts of Alberta. Therefore, there exists a need to develop appropriate air quality statistics. The objectives of the work reported here were to determine the applicability of model generated air quality statistics and to develop by modelling, realistic and representative time series of hourly SO 2 concentrations that could be used to generate the statistics demanded by vegetation response models

  5. THE REMOTE AND MOBILE AIR TRAFFIC CONTROL TOWER AND ITS POSSIBLE APPLICATION TO THE OPERATIONAL AREA

    Tímea VAS

    2014-10-01

    Full Text Available The concept of remote and mobile Air Traffic Control Tower (ATC TWR and its development has started in Europe, Australia and also in the USA, in order to improve the efficiency of Air Traffic Management (ATM systems in terms of air transportation safety. These new technologies are applicable in many countries in peace time, but on mobility reasons these are promoted to achieve commitments in the operational area. This article describes the devices and range of equipment of mobile and remote tower, and their specifications, which can even serve a medium sized airport, furthermore examines, whether how can those provide the air traffic services at an operational airfield.

  6. Air and gas cleaning technology for nuclear applications

    First, M.W.

    1986-01-01

    All large-scale uses of radioactive materials require rigid control of off-gases and generated aerosols. Nuclear air and gas cleaning technology has answered the need from the days of the Manhattan Project to the present with a variety of devices. The one with the longest and most noteworthy service is the HEPA (high efficiency particulate air) filter that originally was referred to as an absolute filter in recognition of its extraordinary particle retention characteristics. Activated-charcoal adsorbers have been employed worldwide for retention of volatile radioiodine in molecular and combined forms and, less frequently, for retention of radioactive noble gases. HEPA filters and activated -charcoal adsorbers are often used with auxiliary devices that serve to extend their effective service life or significantly improve collection efficiency under unfavorable operating conditions. Use of both air cleaning devices and their auxiliaries figure prominently in atomic energy, disposal of high- and low-level nuclear wastes, and in the production of fissile materials. The peaceful uses of nuclear energy would be impossible without these, or equivalent, air- and gas-cleaning devices

  7. Free-Air Gravity Map of Taiwan and Its Applications

    Horng-Yuan Yen

    1990-01-01

    Full Text Available An island-wide gravity in Taiwan was conducted by the Institute of Earth Sciences, Academia Sinica, between 1980 and 1987. The 603 stations at which the gravity values were determined included 308 points in the 500 m or higher mountain range where few readings were available previously. The average spacing of the stations in the present survey is about 7 km apart. A new Free-air gravity anomaly map has been constructed based on these values. The map is dominated by a NNE-SSW gravity high trend with a maximum value of 300 mgal, that follows closely the Central Range, a folded and faulted mountain belt with many peaks 3000 m or higher. The magnitude of the Free-air anomaly in the Taiwan area is quite large compared to that elsewhere in the world. The good correlation between the Free-air anomaly and elevation suggests that the Taiwan area is not in isostatic equilibrium. An average surface rock density of 2.57 g cm-3 is estimated from the Free-air gravity data by using the least-squares method. This value can be used for both terrain and Bouguer corrections. The undulation of the geoid and the deflections of the vertical in the Taiwan area are also calculated by using the Free-air anomaly data. The geoid undulation is not rugged over the Taiwan area. The maximum difference is about 5 m. And the deflection of the vertical seems mainly to be affected by both land and submarine topographies.

  8. A 1.5--4 Kelvin detachable cold-sample transfer system: Application to inertially confined fusion with spin-polarized hydrogens fuels

    Alexander, N.; Barden, J.; Fan, Q.; Honig, A.

    1990-01-01

    A compact cold-transfer apparatus for engaging and retrieving samples at liquid helium temperatures (1.5--4K), maintaining the samples at such temperatures for periods of hours, and subsequently inserting them in diverse apparatuses followed by disengagement, is described. The properties of several thermal radiation-insulating shrouds, necessary for very low sample temperatures, are presented. The immediate intended application is transportable target-shells containing highly spin-polarized deuterons in solid HD or D 2 for inertially confined fusion (ICF) experiments. The system is also valuable for unpolarized high-density fusion fuels, as well as for other applications which are discussed. 9 refs., 6 figs

  9. Cold fusion

    Koster, J.

    1989-01-01

    In this contribution the author the phenomenom of so-called cold fusion, inspired by the memorable lecture of Moshe Gai on his own search for this effect. Thus much of what follows was presented by Dr. Gai; the rest is from independent reading. What is referred to as cold fusion is of course the observation of possible products of deuteron-deuteron (d-d) fusion within deuterium-loaded (dentended) electrodes. The debate over the two vanguard cold fusion experiments has raged under far more public attention than usually accorded new scientific phenomena. The clamor commenced with the press conference of M. Fleishmann and S. Pons on March 23, 1989 and the nearly simultaneous wide circulation of a preprint of S. Jones and collaborators. The majority of work attempting to confirm these observations has at the time of this writing yet to appear in published form, but contributions to conferences and electronic mail over computer networks were certainly filled with preliminary results. To keep what follows to a reasonable length the author limit this discussion to the searches for neutron (suggested by ref. 2) or for excessive heat production (suggested by ref. 1), following a synopsis of the hypotheses of cold fusion

  10. Project COLD.

    Kazanjian, Wendy C.

    1982-01-01

    Describes Project COLD (Climate, Ocean, Land, Discovery) a scientific study of the Polar Regions, a collection of 35 modules used within the framework of existing subjects: oceanography, biology, geology, meterology, geography, social science. Includes a partial list of topics and one activity (geodesic dome) from a module. (Author/SK)

  11. Cold fusion

    Seo, Suk Yong; You, Jae Jun

    1996-01-01

    Nearly every technical information is chased in the world. All of them are reviewed and analyzed. Some of them are chosen to study further more to review every related documents. And a probable suggestion about the excitonic process in deuteron absorbed condensed matter is proposed a way to cold fusion. 8 refs. (Author)

  12. Aerosol composition and its application in air pollution monitoring

    Sadasivan, S.; Negi, B.S.; Meenakshy, V.; Nambi, K.S.V.

    1994-01-01

    Aerosol composition measurements have been carried out in our laboratory using nuclear and related techniques. A brief overview of results from the earlier studies and the scope of the present project are outlined. The analytical procedures in use along with the systems available are detailed. Changes envisaged in sampling and analysis are briefly discussed. Results of two case studies relating to air pollution which are investigated using INAA/EDXRF are presented. The work plan under the CRP is outlined. (author). 11 refs, 2 figs, 5 tabs

  13. Thermodynamic equilibrium-air correlations for flowfield applications

    Zoby, E. V.; Moss, J. N.

    1981-01-01

    Equilibrium-air thermodynamic correlations have been developed for flowfield calculation procedures. A comparison between the postshock results computed by the correlation equations and detailed chemistry calculations is very good. The thermodynamic correlations are incorporated in an approximate inviscid flowfield code with a convective heating capability for the purpose of defining the thermodynamic environment through the shock layer. Comparisons of heating rates computed by the approximate code and a viscous-shock-layer method are good. In addition to presenting the thermodynamic correlations, the impact of several viscosity models on the convective heat transfer is demonstrated.

  14. Application of nuclear air cleaning and treatment codes

    Kriskovich, J.R.

    1995-01-01

    All modifications to existing ventilation systems, as well as any new ventilation systems used on the Hanford Site are required to meet both American Society of Mechanical Engineers (ASME) codes N509 and N510. Difficulties encountered when applying code N509 at the Hanford Site include the composition of the ventilation air stream and requirements related to ventilation equipment procurement. Also, the existing ventilation systems for the waste tanks at the Hanford Site cannot be tested in accordance with code N510 because of the current configuration of these systems

  15. Application of nuclear air cleaning and treatment codes

    Kriskovich, J.R. [Westinghouse Hanford Company, Richland, WA (United States)

    1995-02-01

    All modifications to existing ventilation systems, as well as any new ventilation systems used on the Hanford Site are required to meet both American Society of Mechanical Engineers (ASME) codes N509 and N510. Difficulties encountered when applying code N509 at the Hanford Site include the composition of the ventilation air stream and requirements related to ventilation equipment procurement. Also, the existing ventilation systems for the waste tanks at the Hanford Site cannot be tested in accordance with code N510 because of the current configuration of these systems.

  16. Simulation of Random Events for Air Traffic Applications

    Stéphane Puechmorel

    2018-05-01

    Full Text Available Resilience to uncertainties must be ensured in air traffic management. Unexpected events can either be disruptive, like thunderstorms or the famous volcano ash cloud resulting from the Eyjafjallajökull eruption in Iceland, or simply due to imprecise measurements or incomplete knowledge of the environment. While human operators are able to cope with such situations, it is generally not the case for automated decision support tools. Important examples originate from the numerous attempts made to design algorithms able to solve conflicts between aircraft occurring during flights. The STARGATE (STochastic AppRoach for naviGATion functions in uncertain Environment project was initiated in order to study the feasibility of inherently robust automated planning algorithms that will not fail when submitted to random perturbations. A mandatory first step is the ability to simulate the usual stochastic phenomenons impairing the system: delays due to airport platforms or air traffic control (ATC and uncertainties on the wind velocity. The work presented here will detail algorithms suitable for the simulation task.

  17. Project Overcoat - An Exploration of Exterior Insulation Strategies for 1-1/2-Story Roof Applications in Cold Climates

    Ojczyk, Cindy [NorthernSTAR Building America Partnership, St. Paul, MN (United States); Mosiman, Garrett [NorthernSTAR Building America Partnership, St. Paul, MN (United States); Huelman, Pat [NorthernSTAR Building America Partnership, St. Paul, MN (United States); Schirber, Tom [NorthernSTAR Building America Partnership, St. Paul, MN (United States); Yost, Peter [NorthernSTAR Building America Partnership, St. Paul, MN (United States); Murry, Tessa [NorthernSTAR Building America Partnership, St. Paul, MN (United States)

    2013-04-01

    The development of an alternative method to interior-applied insulation strategies or exterior applied 'band-aids' such as heat tapes and ice belts may help reduce energy needs of millions of 1-1/2 story homes while reducing the risk of ice dam formation. A potential strategy for energy improvement of the roof is borrowed from new construction best practices: Here an 'overcoat' of a continuous air, moisture, and thermal barrier is applied on the outside of the roof structure for improved overall performance. The continuous insulation of this approach facilitates a reduction in thermal bridging which could further reduce energy consumption and bring existing homes closer to meeting the Building America goals for energy reduction. Research favors an exterior approach to deep energy retrofits and ice dam prevention in existing homes. The greatest amount of research focuses on whole house deep energy retrofits leaving a void in roof-only applications. The research is also void of data supporting the hygrothermal performance, durability, constructability, and cost of roof-only exterior overcoat strategies. Yet, contractors interviewed for this report indicate an understanding that exterior approaches are most promising for mitigating ice dams and energy loss and are able to sell these strategies to homeowners.

  18. [A new applicator with regulatable air bag designed for intracavitary brachytherapy of nasopharyngeal carcinoma].

    Zhang, Ning; Wei, Guang-Yu; Tan, Yi-Chang; Huang, Ze-Li; Li, Shao-En; Lu, Zhi-Qian

    2004-10-01

    Nasopharynx applicator used in intracavitary brachytherapy plays an important role in the radiotherapy of nasopharyngeal carcinoma (NPC), its quality affects the efficiency of treatment. This study was to design a new applicator for clinical use. An inexpensive, reusable, and flexible latex nasopharynx applicator was designed. An air bag was placed at 15 mm from the foreside of the applicator, clung to the tube. The edge of air bag is tangent to the axis of tube. When the bag was full of air, the tube would hunch reversely,close to nasopharyngeal vault. After introduced into nasopharynx through middle nasal meatus, the applicator could be fixed in suitable position by its rotation, and air bag regulation, and confirmed its position by simulation. A total of 221 patients with NPC were treated with external beam radiation therapy in our hospital, and boosted HDR brachytherapy using this new applicator. The response rate was 92.6% in the primary tumor group (200/216), and 100% in the recurrent tumor group (5/5). Mucosal necrosis in the posterior or anterior wall of nasopharynx occurred in 5 patients, 8 patients experienced nasal congestion and nasal synechia. This new nasopharynx applicator is easy to operate, painless, and well dosage-distributed. Mucosal necrosis is likely due to higher fractional dose.

  19. Smartphone Air Quality and Atmospheric Aerosol Characterization for Public Health Applications

    Strong, S. B.; Brown, D. M.; Brown, A.

    2014-12-01

    Air quality is a major global concern. Tracking and monitoring air quality provides individuals with the knowledge to make personal decisions about their health and investigate the environment in which they live. Satellite remote sensing and ground-based observations (e.g. Environmental Protection Agency, NASA Aerosol Robotic Network) of air quality is spatially and temporarlly limited and often neglects to provide individuals with the freedom to understand their own personal environment using their personal observations. Given the ubiquitous nature of smartphones, individuals have access to powerful processing and sensing capabilities. When coupled with the appropriate sensor parameters, filters, and algorithms, smartphones can be used both for 'citizen science' air quality applications and 'professional' scientific atmospheric investigations, alike, simplifying data analysis, processing, and improving deployment efficiency. We evaluate the validity of smartphone technology for air quality investigations using standard Cimel CE 318 sun photometry and Fourier Transform Infrared Spectroradiometer (FTIR) observations at specific locations.

  20. Cold fusion

    Suh, Suk Yong; Sung, Ki Woong; Kang, Joo Sang; Lee, Jong Jik

    1995-02-01

    So called 'cold fusion phenomena' are not confirmed yet. Excess heat generation is very delicate one. Neutron generation is most reliable results, however, the records are erratic and the same results could not be repeated. So there is no reason to exclude the malfunction of testing instruments. The same arguments arise in recording 4 He, 3 He, 3 H, which are not rich in quantity basically. An experiment where plenty of 4 He were recorded is attached in appendix. The problem is that we are trying to search cold fusion which is permitted by nature or not. The famous tunneling effect in quantum mechanics will answer it, however, the most fusion rate is known to be negligible. The focus of this project is on the theme that how to increase that negligible fusion rate. 6 figs, 4 tabs, 1512 refs. (Author)

  1. Cold fusion

    Suh, Suk Yong; Sung, Ki Woong; Kang, Joo Sang; Lee, Jong Jik [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of)

    1995-02-01

    So called `cold fusion phenomena` are not confirmed yet. Excess heat generation is very delicate one. Neutron generation is most reliable results, however, the records are erratic and the same results could not be repeated. So there is no reason to exclude the malfunction of testing instruments. The same arguments arise in recording {sup 4}He, {sup 3}He, {sup 3}H, which are not rich in quantity basically. An experiment where plenty of {sup 4}He were recorded is attached in appendix. The problem is that we are trying to search cold fusion which is permitted by nature or not. The famous tunneling effect in quantum mechanics will answer it, however, the most fusion rate is known to be negligible. The focus of this project is on the theme that how to increase that negligible fusion rate. 6 figs, 4 tabs, 1512 refs. (Author).

  2. Analysis of a thermal energy storage system for air cooling–heating application through cylindrical tube

    Anisur, M.R.; Kibria, M.A.; Mahfuz, M.H.; Saidur, R.; Metselaar, I.H.S.C.

    2013-01-01

    Highlights: • Some design parameters of TES system for air cooling–heating application are studied. • Allowable inner radius and thickness of the tube for air flow should be considered. • Better COP is observed by decreasing the PCM container diameter. - Abstract: In order to reduce building energy consumption, thermal energy storage (TES) system has been explored as an alternative solution for air cooling–heating application. Different types of phase change materials (PCMs) along with the different geometries of TES system have been investigated for this application. In this work, a theoretical model was used to analyse the TES system for air cooling–heating application. The heat transfer phenomena in a phase change material (PCM) outside a double wall circular tube with heat transfer fluid (HTF) as air inside the tube were studied. Potassium fluoride tetrahydrate was used as a PCM for the TES system. Laminar forced convection with varying wall temperature was considered to analyse this system. Here, some important design parameters like inner radius and thickness of the tube for HTF flow were also investigated. It was found that an optimum inner radius and thickness of the tube should be considered to design a TES system. Since, significant change in outlet air temperature from the system was observed for reducing inner radius and increasing the thickness of the tube. The coefficients of performances (COPs) for cooling were found 8.79 and 7.20 for 15 mm and 25 mm inner radiuses of the PCM container respectively. Hence, the system can be optimized by reducing the volume of the PCM container. Furthermore, better COP was observed for higher inlet air temperature while the outlet air temperature was almost identical

  3. Air

    Gugele, B.; Scheider, J.; Spangl, W.

    2001-01-01

    In recent years several regulations and standards for air quality and limits for air pollution were issued or are in preparation by the European Union, which have severe influence on the environmental monitoring and legislation in Austria. This chapter of the environmental control report of Austria gives an overview about the legal situation of air pollution control in the European Union and in specific the legal situation in Austria. It gives a comprehensive inventory of air pollution measurements for the whole area of Austria of total suspended particulates, ozone, volatile organic compounds, nitrogen oxides, sulfur dioxide, carbon monoxide, heavy metals, benzene, dioxin, polycyclic aromatic hydrocarbons and eutrophication. For each of these pollutants the measured emission values throughout Austria are given in tables and geographical charts, the environmental impact is discussed, statistical data and time series of the emission sources are given and legal regulations and measures for an effective environmental pollution control are discussed. In particular the impact of fossil-fuel power plants on the air pollution is analyzed. (a.n.)

  4. Land Surface Process and Air Quality Research and Applications at MSFC

    Quattrochi, Dale; Khan, Maudood

    2007-01-01

    This viewgraph presentation provides an overview of land surface process and air quality research at MSFC including atmospheric modeling and ongoing research whose objective is to undertake a comprehensive spatiotemporal analysis of the effects of accurate land surface characterization on atmospheric modeling results, and public health applications. Land use maps as well as 10 meter air temperature, surface wind, PBL mean difference heights, NOx, ozone, and O3+NO2 plots as well as spatial growth model outputs are included. Emissions and general air quality modeling are also discussed.

  5. The results of air treatment process modeling at the location of the air curtain in the air suppliers and ventilation shafts

    Nikolaev Aleksandr

    2017-01-01

    Full Text Available In the existing shaft air heater installations (AHI, that heat the air for air suppliers in cold seasons, a heater channel is used. Some parts of the air from the heater go to the channel, other parts are sucked through a pithead by the general shaft pressure drawdown formed by the main ventilation installation (MVI. When this happens, a mix of two air flows leads to a shaft heat regime violation that can break pressurization of intertubular sealers. The problem of energy saving while airing underground mining enterprises is also very important. The proposed solution of both tasks due to the application of an air curtain is described in the article. In cold seasons the air treatment process should be used and it is offered to place an air curtain in the air suppliers shaft above the place of interface of the calorifer channel to a trunk in order to avoid an infiltration (suction of air through the pithead. It’s recommended to use an air curtain in a ventilation shaft because it reduces external air leaks thereby improving energy efficiency of the MVI work. During the mathematical modeling of ventilation and air preparation process (in SolidWorks Flowsimulation software package it was found out that the use of the air curtain in the air supply shaft can increase the efficiency of the AHI, and reduce the electricity consumption for ventilation in the ventilation shaft.

  6. Exergy analysis of heating, refrigerating and air conditioning methods and applications

    Dincer, Ibrahim

    2015-01-01

    Improve and optimize efficiency of HVAC and related energy systems from an exergy perspective. From fundamentals to advanced applications, Exergy Analysis of Heating, Air Conditioning, and Refrigeration provides readers with a clear and concise description of exergy analysis and its many uses. Focusing on the application of exergy methods to the primary technologies for heating, refrigerating, and air conditioning, Ibrahim Dincer and Marc A. Rosen demonstrate exactly how exergy can help improve and optimize efficiency, environmental performance, and cost-effectiveness. The book also discusses the analysis tools available, and includes many comprehensive case studies on current and emerging systems and technologies for real-world examples. From introducing exergy and thermodynamic fundamentals to presenting the use of exergy methods for heating, refrigeration, and air conditioning systems, this book equips any researcher or practicing engineer with the tools needed to learn and master the application of exergy...

  7. Wireless Sensor Network Applications for the Combat Air Forces

    2006-06-13

    9 2.2.2 weC Mote...variety of enclosures (sometime weather or impact resistant). Since most applications make it infeasible to routinely change batteries, nodes are... environmental monitors or data loggers as examples since extremely small nodes would not be required for those types of activities [Hol00]. A similar

  8. Instantaneous radioiodination of rose bengal at room temperature and a cold-kit therefor. [DOE patent application

    O'Brien, H. Jr.; Hupf, H.B.; Wanek, P.M.

    The disclosure relates to the radioiodination of rose bengal at room temperature and a cold-kit therefor. A purified rose bengal tablet is stirred into acidified ethanol at or near room temperature, until a suspension forms. Reductant-free /sup 125/I/sup -/ is added and the resulting mixture stands until the exchange label reaction occurs at room temperature. A solution of sterile isotonic phosphate buffer and sodium hydroxide is added and the final resulting mixture is sterilized by filtration.

  9. Application of acoustic agglomeration to enhance air filtration efficiency in air-conditioning and mechanical ventilation (ACMV) systems.

    Ng, Bing Feng; Xiong, Jin Wen; Wan, Man Pun

    2017-01-01

    The recent episodes of haze in Southeast Asia have caused some of the worst regional atmospheric pollution ever recorded in history. In order to control the levels of airborne fine particulate matters (PM) indoors, filtration systems providing high PM capturing efficiency are often sought, which inadvertently also results in high airflow resistance (or pressure drop) that increases the energy consumption for air distribution. A pre-conditioning mechanism promoting the formation of particle clusters to enhance PM capturing efficiency without adding flow resistance in the air distribution ductwork could provide an energy-efficient solution. This pre-conditioning mechanism can be fulfilled by acoustic agglomeration, which is a phenomenon that promotes the coagulation of suspended particles by acoustic waves propagating in the fluid medium. This paper discusses the basic mechanisms of acoustic agglomeration along with influencing factors that could affect the agglomeration efficiency. The feasibility to apply acoustic agglomeration to improve filtration in air-conditioning and mechanical ventilation (ACMV) systems is investigated experimentally in a small-scale wind tunnel. Experimental results indicate that this novel application of acoustic pre-conditioning improves the PM2.5 filtration efficiency of the test filters by up to 10% without introducing additional pressure drop. The fan energy savings from not having to switch to a high capturing efficiency filter largely outstrip the additional energy consumed by the acoustics system. This, as a whole, demonstrates potential energy savings from the combined acoustic-enhanced filtration system without compromising on PM capturing efficiency.

  10. Application of acoustic agglomeration to enhance air filtration efficiency in air-conditioning and mechanical ventilation (ACMV systems.

    Bing Feng Ng

    Full Text Available The recent episodes of haze in Southeast Asia have caused some of the worst regional atmospheric pollution ever recorded in history. In order to control the levels of airborne fine particulate matters (PM indoors, filtration systems providing high PM capturing efficiency are often sought, which inadvertently also results in high airflow resistance (or pressure drop that increases the energy consumption for air distribution. A pre-conditioning mechanism promoting the formation of particle clusters to enhance PM capturing efficiency without adding flow resistance in the air distribution ductwork could provide an energy-efficient solution. This pre-conditioning mechanism can be fulfilled by acoustic agglomeration, which is a phenomenon that promotes the coagulation of suspended particles by acoustic waves propagating in the fluid medium. This paper discusses the basic mechanisms of acoustic agglomeration along with influencing factors that could affect the agglomeration efficiency. The feasibility to apply acoustic agglomeration to improve filtration in air-conditioning and mechanical ventilation (ACMV systems is investigated experimentally in a small-scale wind tunnel. Experimental results indicate that this novel application of acoustic pre-conditioning improves the PM2.5 filtration efficiency of the test filters by up to 10% without introducing additional pressure drop. The fan energy savings from not having to switch to a high capturing efficiency filter largely outstrip the additional energy consumed by the acoustics system. This, as a whole, demonstrates potential energy savings from the combined acoustic-enhanced filtration system without compromising on PM capturing efficiency.

  11. Hanford Waste Vitrification Plant Clean Air Act permit application

    1990-04-01

    This document briefly describes the Hanford Site and provides a general overview of the Hanford Waste Vitrification Plant (HWVP). Other topics include sources of emissions, facility operating parameters, facility emissions, pollutant and radionuclide control technology and air quality. The HWVP will convert mixed wastes (high-activity radioactive and hazardous liquid wastes) to a solid vitrified form (borosilicate glass) for disposal. Mixed wastes pretreated in the Hanford Site B Plant will be pumped into double- shell tanks in the 200 East Area for interim storage. This pretreated mixed waste will be batch transferred from interim storage to the HWVP facility, where the waste will be concentrated by evaporation, treated with chemicals, and mixed with glass-forming materials. The mixture will then be continuously fed into an electrically heated glass melter. The molten glass will be poured into canisters that will be cooled, sealed, decontaminated, and stored until the vitrified product can be transferred to a geologic repository. 25 refs., 18 figs., 32 tabs

  12. VHF/UHF filters and multicouplers application of air resonators

    Piette, Bernard

    2013-01-01

    This book describes the various devices used in radio communication and broadcasting to achieve high selectivity filtering and coupling. After providing a background in the basics of microwave theory and more detailed material - including a special chapter on precision and errors in measurement - the reader will find detailed descriptions, manufacturing processes, and, for the most useful instances, a number of worked-through formulas, which will allow engineers and technicians to design circuits or components for filtering or coupling applications. Content is covered in this format across a b

  13. Simulation and Optimization of Air-Cooled PEMFC Stack for Lightweight Hybrid Vehicle Application

    Jingming Liang

    2015-01-01

    Full Text Available A model of 2 kW air-cooled proton exchange membrane fuel cell (PEMFC stack has been built based upon the application of lightweight hybrid vehicle after analyzing the characteristics of heat transfer of the air-cooled stack. Different dissipating models of the air-cooled stack have been simulated and an optimal simulation model for air-cooled stack called convection heat transfer (CHT model has been figured out by applying the computational fluid dynamics (CFD software, based on which, the structure of the air-cooled stack has been optimized by adding irregular cooling fins at the end of the stack. According to the simulation result, the temperature of the stack has been equally distributed, reducing the cooling density and saving energy. Finally, the 2 kW hydrogen-air air-cooled PEMFC stack is manufactured and tested by comparing the simulation data which is to find out its operating regulations in order to further optimize its structure.

  14. Maryland air toxics regulation applicable to a natural gas compressor station

    Weidemann, H.A.; Hoffman, P.M.

    1992-01-01

    Columbia Gas Transmission Corporation submitted an air permit application to the Maryland Department of the Environment to construct a natural gas compressor station near Rutledge, Maryland. The station consists of three natural gas-fueled internal combustion reciprocating engines, each rated at 3200 horsepower. Maximum potential pollutant emissions associated with the station operation did not trigger Prevention of Significant Deterioration review or nonattainment area New Source review. However, a minor source air permit cannot be issued without addressing Maryland's toxic air regulations. Columbia initiated a detailed investigation of toxic air pollutants, including a stack test of an identical engine. Based on this information, the proposed station was subject to the toxic air regulation for acetaldehyde, acrolein, benzene, crotonaldehyde, and formaldehyde. Compliance with the toxic air regulation for crotonaldehyde was demonstrated by having an emission rate less than the threshold emission rate, specified in the regulation. The ambient air quality impact of the other four pollutants was determined using the Industrial Source Complex dispersion model and resulted in predicted concentrations below the pollutant-specific acceptable ambient level. A carcinogenic impact analysis was performed for acetaldehyde, benzene, and formaldehyde to demonstrate compliance with the accepted risk of one in one hundred thousand

  15. Data Visualization with Flash Builder Designing RIA and AIR Applications with Remote Data Sources

    Rocchi, Cesare

    2011-01-01

    Design and create functional applications that interact with remote data sources. You get a thorough introduction to the latest Flash Builder tools learning how you can use the built-in wizards, MXML or pure ActionScript 3 to build information-rich applications for the browser or AIR applications. Hand's on tutorials guide you through each iteration including building user interaction, charting, incorporating audio and video, customizing the UI; and a code repository provides re-usable code that you can modify and deploy in your own applications. *Hand's o

  16. Application of a Dielectric Barrier Discharge Atmospheric Cold Plasma (Dbd-Acp) for Eshcerichia Coli Inactivation in Apple Juice.

    Liao, Xinyu; Li, Jiao; Muhammad, Aliyu Idris; Suo, Yuanjie; Chen, Shiguo; Ye, Xingqian; Liu, Donghong; Ding, Tian

    2018-02-01

    Atmospheric cold plasma (ACP) is a promising non-thermal technology in food industry. In this study, a dielectric barrier discharge (DBD)-ACP exhibited strong bactericidal effect on Escherichia coli in apple juice. Under a 30 to 50 W input power, less than 40 s treatment time was required for DBD-ACP to result in 3.98 to 4.34 log CFU/mL reduction of E. coli in apple juice. The inactivation behavior of ACP on E. coli was well described by the Weibull model. During the treatment, the cell membrane of E. coli was damaged severely by active species produced by plasma, such as hydrogen peroxide, ozone and nitrate. In addition, the ACP exposure had slight effect on the °Brix, pH, titratable acidity (TA), color values, total phenolic content, and antioxidant capacity of apple juice. However, higher level of DBD-ACP treatment, 50 W for more than 10 s in this case, resulted in significant change of the pH, TA, color and total phenolic content of apple juice. The results in this study have provided insight in potential use of DBD-ACP as an alternative to thermal processing for fruit juices in food industry. Escherichia coli O157:H7 in apple juice is a potential risk for public health. This study demonstrated that 30 s cold plasma treatment resulted in more than 4 log CFU/mL reduction under 50 W, while the quality attributes of apple juice were not significantly affected. Therefore, cold plasma technology is a promising alternative substitute of traditional thermal processing for juice pasteurization. © 2018 Institute of Food Technologists®.

  17. Recovery benefits of using a heat and moisture exchange mask during sprint exercise in cold temperatures.

    Seifert, John G; Frost, Jeremy; St Cyr, John A

    2017-01-01

    Breathing cold air can lead to bronchoconstriction and peripheral vasoconstriction, both of which could impact muscular performance by affecting metabolic demands during exercise. Successful solutions dealing with these physiological changes during exercise in the cold has been lacking; therefore, we investigated the influence of a heat and moisture exchange mask during exercise in the cold. There were three trial arms within this study: wearing the heat and moisture exchange mask during the rest periods in the cold, no-mask application during the rest periods in the cold, and a trial at room temperature (22°C). Eight subjects cycled in four 35 kJ sprint sessions with each session separated by 20 min rest period. Workload was 4% of body mass. Mean sprint times were faster with heat and moisture exchange mask and room temperature trial than cold, no-mask trial (133.8 ± 8.6, 134.9 ± 8.8, and 138.0 ± 8.4 s (p = 0.001)). Systolic blood pressure and mean arterial pressure were greater during the cold trial with no mask (15% and 13%, respectively), and heart rate was 10 bpm less during the third rest or recovery period during cold, no mask compared to the heat and moisture exchange mask and room temperature trials. Subjects demonstrated significant decreases in vital capacity and peak expiratory flow rate during the cold with no mask applied during the rest periods. These negative responses to cold exposure were alleviated by the use of a heat and moisture exchange mask worn during the rest intervals by minimizing cold-induced temperature stress on the respiratory system with subsequent maintenance of cardiovascular function.

  18. Improved derivation of the modified BGK collision term and applications to the Hall effect and cold plasma dispersion relation

    Nagata, M.

    1983-01-01

    A derived addition to the BGK collision term,is improved and expressed in simple form. The collision frequency for scattering depends anisotropically on the velocity vector. The improved macroscopic equation of momentum flow is applied to the Hall effect, the cold plasma dispersion relation and the cyclotron resonance. The Hall coefficient which is constant in the case of the BGK collision term now depends on the magnetic field. It is also shown that, compared with the almost symmetric classical curves of cyclotron resonance, the new curves are considerably asymmetric and their half-widths are about 3/2 times the classical ones. (autho)

  19. Robust and Air-Stable Sandwiched Organo-Lead Halide Perovskites for Photodetector Applications

    Mohammed, Omar F.

    2016-02-25

    We report the simplest possible method to date for fabricating robust, air-stable, sandwiched perovskite photodetectors. Our proposed sandwiched structure is devoid of electron or hole transporting layers and also the expensive electrodes. These simpler architectures may have application in the perovskite-only class of solar cells scaling up towards commercialization.

  20. 14 CFR 330.23 - To what address must air carriers send their applications?

    2010-01-01

    ... 14 Aeronautics and Space 4 2010-01-01 2010-01-01 false To what address must air carriers send their applications? 330.23 Section 330.23 Aeronautics and Space OFFICE OF THE SECRETARY, DEPARTMENT OF...) to the following address: U.S. Department of Transportation, Aviation Relief Desk (X-50), 1200 New...

  1. 75 FR 13332 - Application of Charter Air Transport, Inc. for Commuter Authority

    2010-03-19

    ... DEPARTMENT OF TRANSPORTATION Office of the Secretary Application of Charter Air Transport, Inc. for Commuter Authority Correction In notice document 2010-5555 appearing on page 12328 in the issue of Monday, March 15, 2010, make the following correction: In the second column, in the first paragraph, in...

  2. Application of Excel-VBA for Computation of Water Quality Index and Air Pollutant Index

    Ismail Zainal Abidin; Hafizan Juahir; Azman Azid; Ahmad Dasuki Mustafa; Fazureen Azaman

    2015-01-01

    In Malaysia, there are two main indices which are Water Quality Index (WQI) and Air Pollutant Index (API). These indices are used as an indicator for the water quality and ambient air quality status of the environment. In conducting research regarding water and air quality, lots of time has been used to conduct other activities, an application to calculate the indices might come in handy. This project aims to construct an application for the computation of WQI and API using Visual Basic for Applications (VBA) available in Microsoft Excel. VBA is actually a programming language of Microsoft Excel and can be used to write programming and run through in an Excel workbook. The user only required to enter the value for each parameter and then press (OK) to automatically calculate the index. This will provide instance result without wasting time just to refer to the class standard and other formula. The application also has been used as a teaching tool for the secondary students. An environmental based race game called Young Environmental Scientist (YES) Explorace was conducted by Environmental East Coast Research Institute (ESERI) where secondary student are invited as the participant. The application not only provides early exposure to the environmental pollution, but also exposure to the application of computer sciences to the student. (author)

  3. Photon counting altimeter and lidar for air and spaceborne applications

    Vacek, Michael; Michalek, Vojtech; Peca, Marek; Prochazka, Ivan; Blazej, Josef; Kodet, Jan

    2011-06-01

    We are presenting the concept and preliminary design of modular multipurpose device for space segment: single photon counting laser altimeter, atmospheric lidar, laser transponder and one way laser ranging receiver. For all the mentioned purposes, the same compact configuration of the device is appropriate. Overall estimated device weight should not exceed 5 kg with the power consumption below 10 W. The device will consists of three main parts, namely, receiver, transmitter and control and processing unit. As a transmitter a commercial solid state laser at 532 nm wavelength with 10 mW power will be used. The transmitter optics will have a diameter at most of 50 mm. The laser pulse width will be of hundreds of picoseconds order. For the laser altimeter and atmospheric lidar application, the repetition rate of 10 kHz is planned in order to obtain sufficient number of data for a distance value computing. The receiver device will be composed of active quenched Single Photon Avalanche Diode module, tiny optics, and narrow-band optical filter. The core part of the control and processing unit including high precision timing unit is implemented using single FPGA chip. The preliminary device concept includes considerations on energy balance, and statistical algorithms to meet all the mentioned purposes. Recently, the bread board version of the device is under construction in our labs. The concept, construction, and timing results will be presented.

  4. Exergoeconomic analysis of glycol cold thermal energy storage systems for building applications. Paper no. IGEC-1-155

    Bakan, K.; Dincer, I.; Rosen, M.A.

    2005-01-01

    An exergoeconomic analysis is reported of glycol cold thermal energy storage (CTES) systems. Exergoeconomics combines thermodynamic analysis (using both the first and second laws of thermodynamics) with principles of economics, mostly cost accounting. Exergy analysis provides more meaningful and useful information than energy analysis about the efficiency and performance of glycol CTES. The main reason is that traditional analyses are based on mass and energy balances and only external losses can be detected, while exergy analysis measures the quality of energy and includes irreversibility's that occur during any process. According to simulation results, the exergy efficiency of the glycol CTES is roughly 75% less than the energy efficiency due to irreversibility's, and the system efficiency is less than the tank efficiency. Irreversibility's for the overall system are higher than for the tank. Also, the reference ambient temperature has an effect on exergy destruction and efficiency. A 5 o C change in ambient temperature causes a 25% change in exergy efficiency. This result implies that cold energy is more efficient at higher ambient temperatures. Heat losses from the tank depend on the ambient temperature; a 5 o C increase in ambient temperature causes a heat loss increase of 6%. (author)

  5. Application of air traffic control competence reference models as a mean of air navigation services provider’s charge optimization

    В.П. Харченко

    2010-01-01

    Full Text Available  The issue of application of Air Traffic Control (ATC competence reference models as a mean of air navigation services provider’s charge optimization is described in the article, and this issue is interpretated as an optimization task. The data relating to the significant growth of aviation traffic, especially using the airspace of Ukraine, given by authors, and the statement of fact that Air Traffic Management (ATM system’s technical component reliability increasement takes place on the basis of practically invariable psychophysiological abilities of aviation controller, make the substantiation of ANSP provision with the most trained ATC controllers for the work on the working places of ATC Unit actual. The ‘mechanism’ of ATC controllers competence reference model creation is defined step-by step. There is an example of candidate’s for the working place competence quantitative individual model forming as a common criteria of competence, which, in its turn, is the compressed format of all parameters of its working activity, received at the stage of control. The approach, according to which the individual parameters of graduating student’s output model’s professional characteristics, which he received after the examination of his work as Tower controller (ATM Unit of aerodrome control service, approach controller or area control service controller, are compared with the predetermined specialist’s competence reference model, relating to the special working place in ATM system, is supposed here. Notably, the conception, relating to the correspondence of the graduating student’s competence output level to the defined reference model of ATC controller, relating to the special working place of ATM Unit, is realised.

  6. Plate heat exchangers in air conditioning applications. Development of air-coolers, air-heaters and air-conditioning units with low pressure loss. Plattenwaermetauscher in raumlufttechnischen Anlagen. Entwicklung stroemungsoptimierter Luftkuehler, Lufterhitzer und Klimageraete

    Bach, H; Diemer, R; Eisenmann, G; Goettling, D; Madjidi, M

    1989-08-01

    To prepare the development of a water to air plate heat exchanger the state of the art, i.e. the technological knowhow and the design basis are given. The concept and ideas are presented which lead to a slightly wavy plate. Furthermore an exemplary design of a plate heat exchanger and an air-conditioning unit is described and finally the application of plate heat exchangers as direct evaporators and the potential icing problems are investigated. Comparing measured and calculated data shows that the performance of plates with plane surfaces can be predicted fairly well by the presented design methods. The performance of plates with strongly wavy surface however has to be measured. Optimization calculations yield to an air gap of slightly over 4 mm. Comparison with an air-conditioning unit demonstrates that the strongest advantage is for the air cooler (one third of the pressure loss) that a new concept of an air-conditioning unit has lower losses in the fan unit and that it does not need an eliminator. This results in half the volume for the new unit, in a pressure drop of 88%, fan power of 90% and fan revolutions of 50%. (orig./GL).

  7. CFD application on IRWST hydrodynamic analysis during the sparger air venting

    Kim, Y. I.; Hwang, Y. D.; Kim, H. Y.; Bae, Y. Y.; Park, J. K.

    1998-01-01

    A numerical study was performed using preleased FLUENT V4.5 to investigate the applicability of the CFD model for IRWST hydrodynamic analysis during the sparger air venting. Transient calculations were performed with the compressible VOF model on the selected ABB-Atom Unit Cell Test data. This study was mainly focused on the simulation of the bubble formation process in the water pool and time varying pressure history during the air venting from the sparger. The simulated peak pressure was over-predicted in general, but the main frequency is in good agreement with the simulated data. It was shown that there was a strong dependence on the mass discharge rate of the air trapped in the vent line. The peak pressure acceptable for the conservative evaluation of the sparger performance was obtained by reducing the air discharge velocity. This indicates that the proper estimations of the air venting velocity consistent with the sparger design and operating conditions is essential for the application of FLUENT V4.5 to the sparger performance analysis of KNGR

  8. 76 FR 65769 - Application of Friendship Airways, Inc. d/b/a Yellow Air Taxi for Commuter Authority

    2011-10-24

    ... DEPARTMENT OF TRANSPORTATION Office of the Secretary Application of Friendship Airways, Inc. d/b/a Yellow Air Taxi for Commuter Authority AGENCY: Department of Transportation. ACTION: Notice of Order to... issued to Friendship Airways, Inc. d/b/a Yellow Air Taxi and deny its application to resume commuter...

  9. The refrigerant plant engineer. Vol. 2. Application of coldness. 4. new rev. and enl. ed.; Der Kaelteanlagenbauer. Bd. 2. Kaelteanwendungen

    Breidenbach, Karl

    2004-07-01

    Specialists within the range of the refrigerant plant engineering need comprehensive knowledge in the everyday life of occupation. The standard work under consideration very vividly offers an introduction to the technology of refrigerant plants. The second volume of this standard work contains the following chapters: Evaporator; Air cooler and liquid cooler; Air humidification in the cooled room; Condensor; Evaporation cooler and hybrid cooler, cooling towers; Refrigeration compressor; Coolant filling material; Two-phase coolant (binary ice); Water cooling machine with water as refrigerants; Fluid mechanical fundamentals; Expansion valves; Control and adjustment of refrigerant plants; Dimensioning of components; Planning fundamentals; Dimensioning of refrigerant leading pipes for refrigerants.

  10. Modelling of the unsteady behaviour of freezing of products in an evaporator-cooled air current in cold cells; Modellierung des instationaeren Verhaltens des Gefrierens von Produkten im verdampfergekuehlten Luftstrom in Kaeltezellen

    Salem, K.M. [Faculty of Engineering, Univ. of Aden (Yemen)

    1994-12-31

    Analyses on the freezing of food in air currents have until now been mainly confined to the freezing process in the food without consideration to its reaction upon the air current or refrigerating plant. This work uses the example of a cold cell to analyse the interactions between the frozen goods, ambient air, and evaporator as constituted by the unsteady behaviour of their respective temperature fields. This is achieved by mathematical simulative coupling of these three dynamic processes. A calculation model was developed which sets up monograms for main parameters in conventional refrigerating plants. Such a monogram permits determining the optimal operating mode of the plant with due consideration to the quality of the frozen goods and energy consumption. Freezing tests performed to verify the calculations were found to principally confirm them. (orig.) [Deutsch] Die Gefrieren von Lebensmitteln im Luftstrom beschraenkten sich die Analysen bisher hauptsaechlich auf den Gefriervogang im Gut ohne Rueckwirkung auf Luftstrom bzw. Kaelteanlage. In dieser Arbeit wird am Beispiel einer Kaeltezelle das instationaere Verhalten des Temperaturfeldes im Gefriergut, der umgebenden Luft und des Verdampfers in ihrer Wechselwirkung analysiert. Dies gelingt durch mathematisch simulative Kupplung dieser drei dynamischen Vorgaenge. Es wurde ein Rechenmodell erarbeitet, das fuer herkoemmliche Gefrieranlagen Nomogramme der Hauptparameter erstellt. Aus einem derartigen Nomogramm kann die optimale Betriebsweise einer Anlage unter besonderer Beachtung der Gefriergutqualitaet und des Energieverbrauches bestimmt werden. Zur Ueberpruefung des Rechenmodells wurden Gefrierversuche durchgefuehrt, die die Rechenergebnisse prinzipiell bestaetigen. (orig.)

  11. IMT-2000 Satellite Standards with Applications to Mobile Air Traffic Communications Networks

    Shamma, Mohammed A.

    2004-01-01

    The International Mobile Telecommunications - 2000 (IMT-2000) standard and more specifically the Satellite component of it, is investigated as a potential alternative for communications to aircraft mobile users en-route and in terminal area. Its application to Air Traffic Management (ATM) communication needs is considered. A summary of the specifications of IMT-2000 satellite standards are outlined. It is shown via a system research analysis that it is possible to support most air traffic communication needs via an IMT-2000 infrastructure. This technology can compliment existing, or future digital aeronautical communications technologies such as VDL2, VDL3, Mode S, and UAT.

  12. Application for approval of the Cold Lake Expansion Project: volume 3: environmental impact assessment: socio-economic assessment

    Anon.

    1997-02-01

    Anticipated social and economic effects from the construction and operation of the proposed Cold Lake Expansion Project in Alberta were described. The regions and communities that would be directly affected by the project were identified and project impacts with respect to the following areas were analyzed: population and demographics, local economy and labour force, education, health, social and recreational services, protective and emergency services, physical community infrastructure, real estate, and current community planning and land use initiatives. The main sources of information used for the analysis were public statistical data compiled by Statistics Canada, provincial government statistics and municipal planning documents. The overall social impact of the project was expected to range from low to medium. 50 refs., 44 tabs., 6 figs

  13. A simple chemical synthesis of amorphous carbon nanotubes–MnO{sub 2} flake hybrids for cold cathode application

    Sarkar, Sourav [Thin Film and Nanoscience Laboratory, Department of Physics, Jadavpur University, Kolkata 700032 (India); Banerjee, Diptonil; Das, Nirmalya Sankar [School of Material Science and Nanotechnology, Jadavpur University, Kolkata 700032 (India); Chattopadhyay, Kalyan Kumar, E-mail: kalyan_chattopadhyay@yahoo.com [Thin Film and Nanoscience Laboratory, Department of Physics, Jadavpur University, Kolkata 700032 (India); School of Material Science and Nanotechnology, Jadavpur University, Kolkata 700032 (India)

    2015-08-30

    Highlights: • Amorphous carbon nanotubes (aCNTs) have been synthesized chemically. • The walls of the aCNTs have been anchored by MnO{sub 2} nanoflakes. • It is seen for the first time that MnO{sub 2} modified aCNTs show much better field emission property. • Experimental result has also been supported theoretically. • This can acts as doorstep to develop a new hybrid system as a novel cold cathode material. - Abstract: A simple approach has been implemented to synthesize amorphous carbon nanotubes (a-CNTs) and manganese oxide (MnO{sub 2}) hybrid nanostructure at temperature as low as ∼250 °C in open atmosphere. Microscopic studies of the samples revealed that the walls of the a-CNTs were coated uniformly by MnO{sub 2} nanoflakes. The composition of the as prepared sample was studied with the help of energy dispersive X-ray and X-ray photoelectron spectroscopy. Electron field emission study was done in a custom built high vacuum field emission setup for the prepared a-CNT and manganese oxide (MnO{sub 2}) hybrid nanostructure. It is seen that the performance of the a-CNTs as cold cathode emitter has been enhanced greatly when MnO{sub 2} nanoflakes were coated uniformly over it. The turn on field has been reduced from 7.17 to value as low as 3.82 V/mm with enhancement factor increases from 2428 to 6965. Finite element based simulation study theoretically confirms the enhancement of field emission properties of as prepared MnO{sub 2} nanoflake coated a-CNTs. The results have been explained due to enhanced surface roughness leading to higher enhancement factor and overall increase of emission sites.

  14. Cough & Cold Medicine Abuse

    ... Videos for Educators Search English Español Cough & Cold Medicine Abuse KidsHealth / For Teens / Cough & Cold Medicine Abuse ... resfriado Why Do People Use Cough and Cold Medicines to Get High? There's an ingredient in many ...

  15. Evaluation of Ultra-Violet Photocatalytic Oxidation for Indoor AirApplications

    Hodgson, A.T.; Sullivan, D.P.; Fisk, W.J.

    2006-02-01

    Acceptable indoor air quality in office buildings may be achieved with less energy by combining effective air cleaning systems for volatile organic compounds (VOCs) with particle filtration then by relying solely on ventilation. For such applications, ultraviolet photocatalytic oxidation (UVPCO) systems are being developed for VOC destruction. An experimental evaluation of a UVPCO system is reported. The evaluation was unique in that it employed complex mixtures of VOCs commonly found in office buildings at realistically low concentrations. VOC conversion efficiencies varied over a broad range, usually exceeded 20%, and were as high as {approx}80%. Conversion efficiency generally diminished with increased air flow rate. Significant amounts of formaldehyde and acetaldehyde were produced due to incomplete mineralization. The results indicate that formaldehyde and acetaldehyde production rates may need to be reduced before such UVPCO systems can be deployed safely in occupied buildings.

  16. Techno-economic evaluation for the heat integration of vaporisation cold energy in natural gas processing

    Koku, Oludolapo; Perry, Simon; Kim, Jin-Kuk

    2014-01-01

    Highlights: • Development of thermal integration modelling framework for the utilisation of LNG cold energy. • Feasibility study for various design options for the integration of low-temperature cold energy. • Provision of a design approach for achieving efficient use of cold energy in LNG terminals. • Understanding of techno-economic impacts associated with the thermal integration of LNG cold energy. - Abstract: This paper addresses a conceptual study investigating the techno-economic feasibility for the thermal Integration of LNG cold vaporisation energy in power generation applications. In conventional regasification systems, this valuable LNG cold energy is often being wasted to ambient heat sources, representing a thermodynamic inefficient process with a significant thermal impact on the local environment. A combined facility consisting of a non-integrated Combined Cycle Power Plant (CCPP) and an LNG receiving terminal employing traditional Open Rack Vaporisers (ORV) technology, has been modelled, as a base case. Retrofit strategies for the integration of LNG cold energy have been investigated, and their impacts on power production and system efficiency are systematically compared. Retrofit design options considered in this work include the use of a propane Rankine cycle coupled with the direct expansion of natural gas, the integration of a closed-loop water cycle or open-loop water circuit with a steam Rankine cycle, and the facilitation of integrated air cooling for a gas turbine

  17. Cold fusion

    Bush, R.T.

    1991-01-01

    The transmission resonance model (TRM) is combined with some electrochemistry of the cathode surface and found to provide a good fit to new data on excess heat. For the first time, a model for cold fusion not only fits calorimetric data but also predicts optimal trigger points. This suggests that the model is meaningful and that the excess heat phenomenon claimed by Fleischmann and Pons is genuine. A crucial role is suggested for the overpotential and, in particular, for the concentration overpotential, i.e., the hydrogen overvoltage. Self-similar geometry, or scale invariance, i.e., a fractal nature, is revealed by the relative excess power function. Heat bursts are predicted with a scale invariance in time, suggesting a possible link between the TRM and chaos theory. The model describes a near-surface phenomenon with an estimated excess power yield of ∼1 kW/cm 3 Pd, as compared to 50 W/cm 3 of reactor core for a good fission reactor. Transmission resonance-induced nuclear transmutation, a new type of nuclear reaction, is strongly suggested with two types emphasized: transmission resonance-induced neutron transfer reactions yielding essentially the same end result as Teller's hypothesized catalytic neutron transfer and a three-body reaction promoted by standing de Broglie waves. In this paper suggestions for the anomalous production of heat, particles, and radiation are given

  18. Soil-based filtration technology for air purification: potentials for environmental and space life support application

    Nelson, Mark; Bohn, Hinrich

    Soil biofiltration, also known as Soil bed reactor (SBR), technology was originally developed in Germany to take advantage of the diversity in microbial mechanisms to control gases producing malodor in industrial processes. The approach has since gained wider international acceptance and seen numerous improvements, for example, by the use of high-organic compost beds to maximize microbial processes. This paper reviews the basic mechanisms which underlay soil processes involved in air purification, advantages and limitations of the technology and the cur-rent research status of the approach. Soil biofiltration has lower capital and operating/energetic costs than conventional technologies and is well adapted to handle contaminants in moderate concentrations. The systems can be engineered to optimize efficiency though manipulation of temperature, pH, moisture content, soil organic matter and airflow rates. SBR technology was modified for application in the Biosphere 2 project, which demonstrated in preparatory research with a number of closed system testbeds that soil could also support crop plants while also serving as soil filters with air pumps to push air through the soil. This Biosphere 2 research demonstrated in several closed system testbeds that a number of important trace gases could be kept under control and led to the engineering of the entire agricultural soil of Biosphere 2 to serve as a soil filtration unit for the facility. Soil biofiltration, coupled with food crop produc-tion, as a component of bioregenerative space life support systems has the advantages of lower energy use and avoidance of the consumables required for other air purification approaches. Expanding use of soil biofiltration can aid a number of environmental applications, from the mitigation of indoor air pollution, improvement of industrial air emissions and prevention of accidental release of toxic gases.

  19. Eighth joint conference on applications of air pollution meteorology with A & WMA

    NONE

    1994-12-31

    The eighth Joint Conference on Applications of Air Pollution Meteorology, held January 23-28, 1994, again brings together the American Meteorological Society and Air and Waste Management Association with a broader scientific community to examine the role of the atmosphere on current air quality issues. The CAA Amendments non-attainment title has brought renewed interest in the pairing of complex dynamical meteorological models with photochemical air quality models. Requirements that future attainment to regulations be demonstrated with these models invite a new look at model evaluation. The CAAA titles addressing air toxics have brought renewed interest in near-source dispersion and deposition of toxic chemicals. Consequently, this conference is divided into sessions focusing on topics related to these issues. They include: The Dispersion Environment; Meteorology in Emissions Determination; Long-Range and Mesoscale Pollutant Transport and Fate; Meteorology and Photochemistry; Advanced Dispersion Models and Modeling Systems; Topics in Model Evaluation; Complex Flow Affecting Dispersion Near Structures; and Coastal and Complex Terrain Issues Evaluation.

  20. Application of acoustic agglomeration for removing sulfuric acid mist from air stream

    Asghar Sadighzadeh

    2018-01-01

    Full Text Available The application of acoustic fields at high sound pressure levels (SPLs for removing sulfuric acid mists from the air stream was studied. An acoustic agglomeration chamber was used to conduct the experiments. The studied SPLs ranged from 115 to 165 decibel (dB, with three inlet concentrations of acid mist at 5–10, 15–20, and 25–30 ppm. The air flow rates for conducting experiments were 20, 30, and 40 L min−1. The concentration of sulfuric acid mist was measured using US Environmental Protection Agency Method 8 at inlet and outlet of the chamber. The resonance frequencies for experiments were found to be 852, 1410, and 3530 Hz. The maximum acoustic agglomeration efficiency of 86% was obtained at optimum frequency of 852 Hz. The analysis of variance test revealed significant differences between agglomeration efficiency at three resonance frequencies (p-value < 0.001. The maximum acoustic agglomeration efficiency was obtained at SPL level of 165 dB. High initial concentrations of acid mists and lower air flow rates enhance the acoustic agglomeration of mists. High removal efficiency of acid mists from air stream could be achieved by the application of acoustic agglomeration method with appropriate range of frequencies and SPLs. Keywords: Sulfuric acid, Mist, Acoustic agglomeration, SPL

  1. Application of ESE Data and Tools to Air Quality Management: Services for Helping the Air Quality Community use ESE Data (SHAirED)

    Falke, Stefan; Husar, Rudolf

    2011-01-01

    The goal of this REASoN applications and technology project is to deliver and use Earth Science Enterprise (ESE) data and tools in support of air quality management. Its scope falls within the domain of air quality management and aims to develop a federated air quality information sharing network that includes data from NASA, EPA, US States and others. Project goals were achieved through a access of satellite and ground observation data, web services information technology, interoperability standards, and air quality community collaboration. In contributing to a network of NASA ESE data in support of particulate air quality management, the project will develop access to distributed data, build Web infrastructure, and create tools for data processing and analysis. The key technologies used in the project include emerging web services for developing self describing and modular data access and processing tools, and service oriented architecture for chaining web services together to assemble customized air quality management applications. The technology and tools required for this project were developed within DataFed.net, a shared infrastructure that supports collaborative atmospheric data sharing and processing web services. Much of the collaboration was facilitated through community interactions through the Federation of Earth Science Information Partners (ESIP) Air Quality Workgroup. The main activities during the project that successfully advanced DataFed, enabled air quality applications and established community-oriented infrastructures were: develop access to distributed data (surface and satellite), build Web infrastructure to support data access, processing and analysis create tools for data processing and analysis foster air quality community collaboration and interoperability.

  2. Imaging with cold neutrons

    Lehmann, E.H.; Kaestner, A.; Josic, L.; Hartmann, S.; Mannes, D.

    2011-01-01

    research field in its own sing the Bragg edge behavior and its modification to contribute to material research by the direct visualization of textures and the observation of stress and strain. This topic is still in the beginning but has some important relevance for the design of future beam lines for imaging at the pulsed spallation sources. Considering the neutrons to be waves, the cold energy range is important to push and to investigate phase effects in detail with high spatial resolution. Although a lot of studies have been done in this respect previously, there is enough space to study refraction at the edges, diffraction and total reflection with the best possible accuracy, and to figure out when and why neutrons interfere. Phase contrast methods like grating interference methods have to be implemented as a user option, which enables one to define their future application range.

  3. Cold metal transfer spot plug welding of AA6061-T6-to-galvanized steel for automotive applications

    Cao, R.; Huang, Q.; Chen, J.H.; Wang, Pei-Chung

    2014-01-01

    Highlights: • Two Al-to-galvanized steel spot plug welding joints were studied by CMT method. • The optimum process variables for the two joints were gotten by orthogonal test. • Connection mechanism of the two joints were discussed. -- Abstract: In this study, cold metal transfer (CMT) spot plug joining of 1 mm thick Al AA6061-T6 to 1 mm thick galvanized steel (i.e., Q235) was studied. Welding variables were optimized for a plug weld in the center of a 25 mm overlap region with aluminum 4043 wire and 100% argon shielding gas. Microstructures and elemental distributions were characterized by scanning electron microscopy with energy dispersive X-ray spectrometer. Mechanical testing of CMT spot plug welded joints was conducted. It was found that it is feasible to join Al AA6061T6-to-galvanized steel by CMT spot plug welding method. The process variables for two joints with Al AA6061T6-to-galvanized mild steel and galvanized mild steel-to-Al AA6061T6 are optimized. The strength of CMT spot welded Al AA6061T6-to-galvanized mild steel is determined primarily by the strength and area of the brazed interface. While, the strength of the galvanized mild steel-to-Al AA6061T6 joint is mainly dependent upon the area of the weld metal

  4. Surface modification of a natural zeolite by treatment with cold oxygen plasma: Characterization and application in water treatment

    De Velasco-Maldonado, Paola S.; Hernández-Montoya, Virginia; Montes-Morán, Miguel A.; Vázquez, Norma Aurea-Rangel; Pérez-Cruz, Ma. Ana

    2018-03-01

    In the present work the possible surface modification of natural zeolite using cold oxygen plasma was studied. The sample with and without treatment was characterized using nitrogen adsorption isotherms at -196 °C, FT-IR spectroscopy, SEM/EDX analysis and X-Ray Diffraction. Additionally, the two samples were used for the removal of lead and acid, basic, reactive and food dyes in batch systems. The natural zeolite was found to be a mesoporous material with a low specific surface area (23 m2/g). X-ray patterns confirmed that clinoptilolite was the main crystal structure present in the natural zeolite. The molecular properties of dyes and the zeolitic structure were studied using molecular simulation, with the purpose to understand the adsorption mechanism. The results pointed out that only the roughness of the clinoptilolite was affected by the plasma treatment, whereas the specific surface area, chemical functionality and crystal structure remained constant. Finally, adsorption results confirmed that the plasma treatment had no significant effects on the dyes and lead retention capacities of the natural zeolite.

  5. Meteorology and air-quality in a mega-city: application to Tehran, Iran

    Malakooti, Hossein

    2010-01-01

    The influence of a mega-city on the atmospheric boundary layer and surface conditions was examined in the complex-terrain, semi-arid Tehran region using the Pennsylvania State University/National Center for Atmospheric Research fifth-generation Mesoscale Model (MM5) during a high pollution period. In addition, model sensitivity studies were conducted to evaluate the performance of the urban canopy and urban soil model 'SM2-U (3D)' parameterization on the meteorological fields and ground level air pollutant concentrations in this area. The topographic flows and urban effects were found to play important roles in modulating the wind and temperature fields, and the urbanized areas exerted important local effects on the boundary layer meteorology. An emission inventory of air pollutants and an inventory of heat generation were developed and updated for 2005 in this work. Emissions from on-road motor vehicles constitute a major portion of the emission inventory and play the most important role in terms of contributions of air pollutants to the atmosphere in Tehran. By using a detailed methodology, we calculated spatial and temporal distributions of the anthropogenic heat flux (Qf) for Tehran during 2005. Wintertime Qf is larger than summertime Qf, which reflects the importance of heating emissions from buildings and traffic during cold and warm period respectively. Different urban parameterizations were used as a tool to investigate the modifications induced by the presence of an urban area in the area of interest. It was found that, for local meteorological simulations, the drag-force approach coupled with an urban soil model (DA-SM2-U) is preferable to the roughness approach (RA-SLAB). The comparisons indicated that the most important features of the wind, temperature and turbulent fields in urban areas are well reproduced by the DA-SM2-U configuration with the anthropogenic heat flux being taken into account (i.e., 'DA-SM2-U Qf: On' option). This

  6. Extraordinary acoustic transmission through annuluses in air and its applications in acoustic beam splitter and concentrator

    Ge, Yong; Liu, Shu-sen; Yuan, Shou-qi; Xia, Jian-ping; Guan, Yi-jun; Sun, Hong-xiang; Zhang, Shu-yi

    2016-01-01

    We report an extraordinary acoustic transmission through two layer annuluses made of metal cylinders in air both numerically and experimentally. The effect arises from the enhancement and reconstruction of the incident source induced by different Mie-resonance modes of the annuluses. The proposed system takes advantages of the consistency in the waveform between the input and output waves, the high amplitude amplification of output waves, and the easy adjustment of structure. More interestingly, we investigate the applications of the extraordinary acoustic transmission in the acoustic beam splitter and acoustic concentrator. Our finding should have an impact on ultrasonic applications.

  7. Air Force electrochemical power research and technology program for space applications

    Allen, Douglas

    1987-01-01

    An overview is presented of the existing Air Force electrochemical power, battery, and fuel cell programs for space application. Present thrusts are described along with anticipated technology availability dates. Critical problems to be solved before system applications occur are highlighted. Areas of needed performance improvement of batteries and fuel cells presently used are outlined including target dates for key demonstrations of advanced technology. Anticipated performance and current schedules for present technology programs are reviewed. Programs that support conventional military satellite power systems and special high power applications are reviewed. Battery types include bipolar lead-acid, nickel-cadmium, silver-zinc, nickel-hydrogen, sodium-sulfur, and some candidate advanced couples. Fuel cells for pulsed and transportation power applications are discussed as are some candidate advanced regenerative concepts.

  8. Relationships of self-identified cold tolerance and cold-induced vasodilatation in the finger

    Park, Joonhee; Lee, Joo-Young

    2016-04-01

    This study was conducted to investigate relationships of self-identified cold tolerance and cold-induced vasodilatation (CIVD) in the finger. Nine males and 34 females participated in the following 2 tests: a CIVD test and a self-reported survey. The CIVD test was conducted 30-min cold-water immersion (3.8 ± 0.3 °C) of the middle finger at an air temperature of 27.9 ± 0.1 °C. The self-reported questionnaire consisted of 28 questions about whole and local body cold and heat tolerances. By a cluster analysis on the survey results, the participants were divided into two groups: high self-identified cold tolerance (HSCT, n = 25) and low self-identified cold tolerance (LSCT, n = 18). LSCT had lower self-identified cold tolerance ( P cold or heat tolerance had relationships with cold tolerance index, T max, and amplitude ( P cold tolerance classified through a standardized survey could be a good index to predict physiological cold tolerance.

  9. Feasibility study of a novel dew point air conditioning system for China building application

    Zhao, Xudong; Yang, Shuang; Duan, Zhiyin; Riffat, Saffa B. [School of the Built Environment, University of Nottingham, University Park, Nottingham NG7 2RD (United Kingdom)

    2009-09-15

    The paper investigated the feasibility of a novel dew point evaporative cooling for air conditioning of buildings in China regions. The issues involved include analyses of China weather conditions, investigation of availability of water for dew point cooling, and assessment of cooling capacity of the system within various regions of China. It is concluded that the dew point system is suitable for most regions of China, particularly northern and west regions of China where the climate is hot and dry during the summer season. It is less suitable for Guangzhou and Shanghai where climates are hot and humid. However, an air pre-treatment process involving a silica-gel dehumidification will enable the technology to be used for these humid areas. Lower humidity results in a higher difference between the dry bulb and dew point of the air, which benefits the system in terms of enhancing its cooling performance. Tap water has adequate temperature to feed the system for cooling and its consumption rate is in the range 2.6-3 litres per kWh cooling output. The cooling output of the system ranges from 1.1 to 4.3 W per m{sup 3}/h air flow rate in China, depending on the region where the system applies. For a unit with 2 kW of cooling output, the required air volume flow rate varies with its application location and is in the range 570-1800 m{sup 3}/h. For a 50 m{sup 2} building with 60 W/m{sup 2} cooling load, if the system operates at working hours, i.e., 09:00 to 17:00 h, its daily water consumption would be in the range of 60-70 litres. Compared with mild or humid climates, the dry and hot climates need less air volume flow rate and less water. (author)

  10. Development of a compound energy system for cold region houses using small-scale natural gas cogeneration and a gas hydrate battery

    Obara, Shin'ya; Kikuchi, Yoshinobu; Ishikawa, Kyosuke; Kawai, Masahito; Yoshiaki, Kashiwaya

    2015-01-01

    In this study, an independent energy system for houses in cold regions was developed using a small-scale natural gas CGS (cogeneration), air-source heat pump, heat storage tank, and GHB (gas hydrate battery). Heat sources for the GHB were the ambient air and geothermal resources of the cold region. The heat cycle of CO 2 hydrate as a source of energy was also experimentally investigated. To increase the formation speed of CO 2 hydrates, a ferrous oxide–graphite system catalyst was used. The ambient air of cold regions was used as a heat source for the formation process (electric charge) of the GHB, and the heat supplied by a geothermal heat exchanger was used for the dissociation process (electric discharge). Using a geothermal heat source, fuel consumption was halved because of an increased capacity for hydrate formation in the GHB, a shortening of the charging and discharging cycle, and a decrease in the freeze rate of hydrate formation space. Furthermore, when the GHB was introduced into a cold region house, the application rate of renewable energy was 47–71% in winter. The spread of the GHB can greatly reduce fossil fuel consumption and the associated greenhouse gases released from houses in cold regions. - Highlights: • Compound energy system for cold region houses by a gas hydrate battery was proposed. • Heat sources of a gas hydrate battery are exhaust heat of the CGS and geothermal. • Drastic reduction of the fossil fuel consumption in a cold region is realized

  11. The European programme to develop the Wells air turbine for applications in wave energy

    White, P.R.S.

    1996-01-01

    The European Wave Energy Pilot Plants currently under construction are utilising Wells air turbines to convert oscillating pneumatic energy within the converters to unidirectional energy of rotation for direct coupling to electrical generators. The Wells turbine has also been proposed for future off shore wave energy converters (eg SEA CLAM). The European research programme was to produce Recommendations for selecting the most appropriate air turbine for a given wave power application. The work concentrated on collating existing work on the Wells turbine, and extending it to examine rotor aerodynamics, the effect and practicality of variable pitch rotor blades, the effect on performance of interaction with the converter, and the preparation of design guide lines. A comparison between the output of a Wells turbine and a conventional air turbine with rectifying valves when subjected to the same random reversing air flow was also conducted. This paper gives a brief outline of the programme of work, and concludes that at this stage of development the Wells turbine is the preferred choice of prime mover for pneumatic wave energy converters. (Author)

  12. Geothermal as a heat sink application for raising air conditioning efficency

    Ibrahim, Hesham Safwat Osman Mohamed

    2016-04-01

    Objective: Geothermal applications in heating, ventilation, air-conditioning is a US technology for more than 30 years old ,which saves more than 30% average energy cost than the traditional air-conditioning systems systems. Applying this technology in Middle East and African countries would be very feasible specially in Egypt specially as it suffers Electric crisis --The temperature of the condensers and the heat rejecting equipment is much higher than the Egyptian land at different depth which is a great advantages, and must be measured, recorded, and studied accurately -The Far goal of the proposal is to construct from soil analysis a temperature gradient map for Egypt and , African countries on different depth till 100 m which is still unclear nowadays and must be measured and recorded in databases through researches - The main model of the research is to study the heat transfer gradient through the ground earth borehole,grout,high density polyethylene pipes , and water inlet temperature which affect the electric efficiency of the ground source heat pump air conditioning unit Impact on the Region: Such research result will contribute widely in Energy saving sector specially the air conditioning sector in Egypt and the African countries which consumes more than 30% of the electric consumption of the total consumption . and encouraging Green systems such Geothermal to be applied

  13. Application of gamma densitometer for measurement of void fraction in liquid hydrogen moderator of HANARO cold neutron source

    Kim, Myong-Seop; Choi, Jungwoon; Sun, Gwang-Min; Lee, Kye-Hong

    2009-01-01

    The void fraction in the liquid hydrogen used for the moderator of the HANARO cold neutron source (CNS) was measured by using a gamma densitometer technique. A mock-up of the HANARO CNS facility with an electric heating system as the heat source instead of radiations was constructed. The photon transmissions through the hydrogen moderator were simulated to search for an optimum experimental condition. From the simulation, it was confirmed that Am-241 was suitable for the measurement of the void fraction in the liquid hydrogen medium. A gamma densitometer using the Am-241 gamma-ray source was designed and installed at the mock-up of the CNS. The attenuation of 59.5 keV gamma-rays from the Am-241 through the hydrogen medium was measured by using an HPGe detector. The void fraction was determined using the amount of the gamma-ray attenuation. The void fractions in the hydrogen moderator were measured for stable thermo-siphon loops with several electric heat loads applied to the moderator cell of the CNS mock-up. The longitudinal distribution of the void fraction inside the moderator cell was also determined. The void fraction measured at a heat load of 720 W had values of 8-41% depending on the height from the bottom of the moderator cell. The overall void fraction was obtained by volume-weighted averaging of its longitudinal distribution. The void fraction at the nuclear heating power expected at the normal operation condition of the HANARO CNS facility was determined to be about 20%. The large uncertainty was expected in the void fraction determination by a gamma densitometer for the liquid hydrogen medium with the void fraction less than 10%. When the void fraction of the liquid hydrogen was near 20%, the uncertainty in the void fraction determination by using a gamma densitometer became relatively small, and it was regarded as an acceptable level. The measurements for the void fraction will be very useful for the design and operation of the HANARO CNS.

  14. Application of the user-centred design process according ISO 9241-210 in air traffic control.

    König, Christina; Hofmann, Thomas; Bruder, Ralph

    2012-01-01

    Designing a usable human machine interface for air traffic control is challenging and should follow approved methods. The ISO 9241-210 standard promises high usability of products by integrating future users and following an iterative process. This contribution describes the proceeding and first results of the analysis and application of ISO 9241-210 to develop a planning tool for air traffic controllers.

  15. [Application of Land-use Regression Models in Spatial-temporal Differentiation of Air Pollution].

    Wu, Jian-sheng; Xie, Wu-dan; Li, Jia-cheng

    2016-02-15

    With the rapid development of urbanization, industrialization and motorization, air pollution has become one of the most serious environmental problems in our country, which has negative impacts on public health and ecological environment. LUR model is one of the common methods simulating spatial-temporal differentiation of air pollution at city scale. It has broad application in Europe and North America, but not really in China. Based on many studies at home and abroad, this study started with the main steps to develop LUR model, including obtaining the monitoring data, generating variables, developing models, model validation and regression mapping. Then a conclusion was drawn on the progress of LUR models in spatial-temporal differentiation of air pollution. Furthermore, the research focus and orientation in the future were prospected, including highlighting spatial-temporal differentiation, increasing classes of model variables and improving the methods of model development. This paper was aimed to popularize the application of LUR model in China, and provide a methodological basis for human exposure, epidemiologic study and health risk assessment.

  16. Network Theory: A Primer and Questions for Air Transportation Systems Applications

    Holmes, Bruce J.

    2004-01-01

    A new understanding (with potential applications to air transportation systems) has emerged in the past five years in the scientific field of networks. This development emerges in large part because we now have a new laboratory for developing theories about complex networks: The Internet. The premise of this new understanding is that most complex networks of interest, both of nature and of human contrivance, exhibit a fundamentally different behavior than thought for over two hundred years under classical graph theory. Classical theory held that networks exhibited random behavior, characterized by normal, (e.g., Gaussian or Poisson) degree distributions of the connectivity between nodes by links. The new understanding turns this idea on its head: networks of interest exhibit scale-free (or small world) degree distributions of connectivity, characterized by power law distributions. The implications of scale-free behavior for air transportation systems include the potential that some behaviors of complex system architectures might be analyzed through relatively simple approximations of local elements of the system. For air transportation applications, this presentation proposes a framework for constructing topologies (architectures) that represent the relationships between mobility, flight operations, aircraft requirements, and airspace capacity, and the related externalities in airspace procedures and architectures. The proposed architectures or topologies may serve as a framework for posing comparative and combinative analyses of performance, cost, security, environmental, and related metrics.

  17. U.S. Environmental Protection Agency Clear Air Act notice of construction for the spent nuclear fuel project - Cold Vacuum Drying Facility, project W-441

    Turnbaugh, J.E.

    1996-01-01

    This document provides information regarding the source and the estimated quantity of potential airborne radionuclide emissions resulting from the operation of the Cold Vacuum Drying (CVD) Facility. The construction of the CVD Facility is scheduled to commence on or about December 1996, and will be completed when the process begins operation. This document serves as a Notice of Construction (NOC) pursuant to the requirements of 40 Code of Federal Regulations (CFR) 61 for the CVD Facility. About 80 percent of the U.S. Department of Energy's spent nuclear fuel (SNF) inventory is stored under water in the Hanford Site K Basins. Spent nuclear fuel in the K West Basin is contained in closed canisters, while the SNF in the K East Basin is in open canisters, which allow release of corrosion products to the K East Basin water. Storage of the current inventory in the K Basins was originally intended to be on an as-needed basis to sustain operation of the N Reactor while the Plutonium-Uranium Extraction (PUREX) Plant was refurbished and restarted. The decision in December 1992 to deactivate the PURF-X Plant left approximately 2,100 MT (2,300 tons) of uranium as part of the N Reactor SNF in the K Basins with no means for near-term removal and processing. The CVD Facility will be constructed in the 100 Area northwest of the 190 K West Building, which is in close proximity to the K East and K West Basins (Figures 1 and 08572). The CVD Facility will consist of five processing bays, with four of the bays fully equipped with processing equipment and the fifth bay configured as an open spare bay. The CVD Facility will have a support area consisting of a control room, change rooms, and other functions required to support operations

  18. Study on climate control of dwellings using underground air tunnel in the cold region. Part 1. Cooling performance of the underground air tunnel connected to a small-scaled test house; Kanreichi ni okeru chika air tunnel ni yoru junetsukankyo kaizen ni kansuru kenkyu. 1. Shokibo shiken kaoku ni okeru kaki no ryobo seino hyoka

    Miki, Y; Sanji, H; Ito, J; Komoda, T; Mitsuoka, K; Mogami, S [Kitami Institute of Technology, Hokkaido (Japan)

    1997-11-25

    Underground air tunnel is provided for cooling an experimentally built small house and the cooling performance is examined at Kitami Institute of Technology, Hokkaido. The house is provided with 120mm-thick layers of insulating material under the floor and inside the side walls and partitioning walls. The windows are equipped with blinds, with reed screens positioned outside to cover the windows. The air tunnel is a hard vinyl chloride tube, 200mm in internal diameter. It is buried 4.5m deep in the ground, and extends as long as 27m. A filter-provided 72W blower installed at the tunnel outlet is driven to force air through. As for the natural soil temperature in summer, it is found variable between 7.2 and 8.5degC. As the result of the experiment, it is found that thanks to the underground tunnel the room temperature is kept below 27degC even when the maximum temperature in the daytime is 30degC or higher provided the air flow is appropriately regulated. In this experiment, the maximum rate of instantaneously removed heat is approximately 2.5 times higher than the values in other previously reported experiments. The daily coefficient of performance is 6.5-11.1, again higher than the previously reported values. Different from application in warm regions, the effect of rise in the surrounding soil temperature on the cooling performance is not so conspicuous. 3 refs., 12 figs., 1 tab.

  19. A long-term ultrahigh temperature application of layered silicide coated Nb alloy in air

    Sun, Jia; Fu, Qian-Gang; Li, Tao; Wang, Chen; Huo, Cai-Xia; Zhou, Hong; Yang, Guan-Jun; Sun, Le

    2018-05-01

    Nb-based alloy possessed limited application service life at ultrahigh temperature (>1400 °C) in air even taking the effective protective coating strategy into consideration for last decades. In this work a long duration of above 128 h at 1500 °C in air was successfully achieved on Nb-based alloy thanked to multi-layered silicide coating. Through optimizing interfaces, the MoSi2/NbSi2 silicide coating with Al2O3-adsorbed-particles layer exhibited three-times higher of oxidation resistance capacity than the one without it. In MoSi2-Al2O3-NbSi2 multilayer coating, the Al2O3-adsorbed-particles layer playing as an element-diffusion barrier role, as well as the formed porous Nb5Si3 layer as a stress transition zone, contributed to the significant improvement.

  20. Extended plasma channels created by UV laser in air and their application to control electric discharges

    Zvorykin, V. D.; Ionin, A. A.; Levchenko, A. O.; Seleznev, L. V.; Sinitsyn, D. V.; Smetanin, I. V.; Ustinovskii, N. N.; Shutov, A. V.

    2015-01-01

    Results are presented from a series of experimental and theoretical studies on creating weakly ionized extended plasma channels in atmospheric air by 248-nm UV laser radiation and their application to control long high-voltage discharges. The main mechanisms of air ionization by UV laser pulses with durations from 100 fs to 25 ns and intensities in the ranges of 3×10 11 –1.5×10 13 and 3×10 6 –3×10 11 W/cm 2 , respectively, which are below the threshold for optical gas breakdown, as well as the main relaxation processes in plasma with a density of 10 9 –10 17 cm −3 , are considered. It is shown that plasma channels in air can be efficiently created by amplitude-modulated UV pulses consisting of a train of subpicosecond pulses producing primary photoelectrons and a long UV pulse suppressing electron attachment and sustaining the density of free electrons in plasma. Different modes of the generation and amplification of trains of subterawatt subpicosecond pulses and amplitude-modulated UV pulses with an energy of several tens of joules were implemented on the GARPUN-MTW hybrid Ti:sapphire-KrF laser facility. The filamentation of such UV laser beams during their propagation in air over distances of up to 100 m and the parameters of the corresponding plasma channels were studied experimentally and theoretically. Laser initiation of high-voltage electric discharges and control of their trajectories by means of amplitude-modulated UV pulses, as well as the spatiotemporal structure of breakdowns in air gaps with length of up to 80 cm, were studied

  1. Heat and cold accumulators in vehicles

    Kauranen, P.; Wikstroem, L. (VTT Technical Research Centre of Finland, Advanced Materials, Tampere (Finland)); Heikkinen, J. (VTT Technical Research Centre of Finland, Building Services and Indoor Environment, Espoo (Finland)); Laurikko, J.; Elonen, T. (VTT Technical Research Centre of Finland, Emission Control, Espoo (Finland)); Seppaelae, A. (Helsinki Univ. of Technology, Applied Thermodynamics, Espoo (Finland)). Email: ari.seppala@tkk.fi

    2009-07-01

    Phase Change Material (PCM) based heat and cold accumulators have been tailored for transport applications including a mail delivery van as well as the cold chains of foodstuff and blood products. The PCMs can store relative large amount of thermal energy in a narrow temperature interval as latent heat of fusion of their melting and crystallization processes. Compact heat and cold accumulators can be designed using PCMs. The aim of the project has been to reduce the exhaust gas and noise emissions and improve the fuel economy of the transport systems and to improve the reliability of the cold chains studied by storing thermal energy in PCM accumulators. (orig.)

  2. A transcription factor for cold sensation!

    Milbrandt Jeffrey

    2005-03-01

    Full Text Available Abstract The ability to feel hot and cold is critical for animals and human beings to survive in the natural environment. Unlike other sensations, the physiology of cold sensation is mostly unknown. In the present study, we use genetically modified mice that do not express nerve growth factor-inducible B (NGFIB to investigate the possible role of NGFIB in cold sensation. We found that genetic deletion of NGFIB selectively affected behavioral responses to cold stimuli while behavioral responses to noxious heat or mechanical stimuli were normal. Furthermore, behavioral responses remained reduced or blocked in NGFIB knockout mice even after repetitive application of cold stimuli. Our results provide strong evidence that the first transcription factor NGFIB determines the ability of animals to respond to cold stimulation.

  3. Cold thermal injury from cold caps used for the prevention of chemotherapy-induced alopecia.

    Belum, Viswanath Reddy; de Barros Silva, Giselle; Laloni, Mariana Tosello; Ciccolini, Kathryn; Goldfarb, Shari B; Norton, Larry; Sklarin, Nancy T; Lacouture, Mario E

    2016-06-01

    The use of scalp cooling for the prevention of chemotherapy-induced alopecia (CIA) is increasing. Cold caps are placed onto the hair-bearing areas of the scalp for varying time periods before, during, and after cytotoxic chemotherapy. Although not yet reported, improper application procedures could result in adverse events (AEs). At present, there are no evidence-based scalp cooling protocols, and there is no regulatory oversight of their use. To report the occurrence of cold thermal injury (frostbite) on the scalp, following the use of cold caps for the prevention of CIA. We identified four patients who developed cold thermal injuries on the scalp following the application of cold caps. Medical records were analyzed to retrieve the demographic and clinical characteristics. The cold thermal injuries in our patients were grade 1/2 in severity and improved with topical interventions and interruption of cold cap use, although grade 1 persistent alopecia ensued in 3 patients. The true incidence of such injuries in this setting, however, remains unknown. Cold thermal injuries are likely infrequent and preventable AEs that may result from improper device application procedures during cold cap use. Although these untoward events are usually mild to moderate in severity, the potential occurrence of long-term sequelae (e.g., permanent alopecia and scarring) or the need to discontinue cold cap use, are not known. Prospective studies are needed to further elucidate the risk and standardize healthcare delivery methods, and to improve patient/supportive/healthcare provider education.

  4. Grooved cold moderator tests

    Inoue, K.; Kiyanagi, Y.; Iwasa, H.; Watanabe, N.; Ikeda, S.; Carpenter, J.M.; Ishikawa, Y.

    1983-01-01

    We performed some grooved cold moderator experiments for methane at 20 K by using the Hokkaido University linac to obtain information to be used in the planning of the KENS-I' project. Cold neutron gains, spatial distribution of emitted beams and time distribution of the neutrons in the grooved cold moderator were measured. Furthermore, we assessed the effects of the grooved cold moderator on the performances of the spectrometers presently installed at the KENS-I cold source. We concluded that the grooved cold moderator benefited appreciably the performances of the spectrometers

  5. The dosage of mercury vapours in air. Application to an atmospheric control

    Francois, H.; Vettier, M.C.; Moser, Y.

    1961-01-01

    The authors have studied a technique making it possible to trap completely the mercury vapours in the atmosphere and to analyse them with precision; their object is an application to an atmospheric control. The analytical method used is particularly sensitive and makes possible the determination of 1 micro-gram of mercury in a 1000 litre sample of air with an accuracy of 2 per cent. The total time for the operation can be estimated to be about 2 1/2 hours, including the analysis. The operations are straightforward and can be carried out by specialised personnel after a short training. (author) [fr

  6. Phenomenally High Transduction Air/gas Transducers for Practical Non-Contact Ultrasonic Applications

    Bhardwaj, Mahesh C.

    2009-03-01

    Based on novel acoustic impedance matching layers and high coupling piezoelectric materials this paper describes exceptionally high air/gas transduction ultrasonic transducers. By providing applications oriented performance of these transducers we also usher in the era of much desired Non-Contact Ultrasound (NCU) testing and analysis of a wide range of materials including early stage formation of materials such as uncured composite prepregs, green ceramics and powder metals, plastics, elastomers, porous, hygroscopic, chemically bonded and other materials. Besides quality control, ultimately NCU offers timely opportunities for cost-effective materials production, energy savings, and environment protection.

  7. Application of cryptogams as monitoring organisms of metal air pollution in Denmark

    Rasmussen, L; Pilegaard, K; Gydesen, H

    1980-01-01

    A reviewing statement of the use of bryophytes and lichens as biologically monitoring organisms of metal air pollution in Denmark is given with comments on the difficulties of the different methods. On the basis of presented investigations the advantages of the application of epiphytically growing bryophytes over epigeically growing species are discussed. It is concluded that epiphytes are more effective accumulators of the metals with the highest binding affinity, e.g., Cu, Fe, Pb, than epigeically growing species. Furthermore, the specific habitat conditions for epiphytes give a higher degree of comparability between different sampling sites, although epiphytes still are dependent on the existence of a suitable phorophyte on the site.

  8. Air Dispersion Modeling for the INL Application for a Synthetic Minor Sitewide Air Quality Permit to Construct with a Facility Emission Cap Component

    Sondrup, Andrus Jeffrey [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2015-10-01

    The Department of Energy Idaho Operations Office (DOE-ID) is applying for a synthetic minor, Sitewide, air quality permit to construct (PTC) with a facility emission cap (FEC) component from the Idaho Department of Environmental Quality (DEQ) for Idaho National Laboratory (INL) to limit its potential to emit to less than major facility limits for criteria air pollutants (CAPs) and hazardous air pollutants (HAPs) regulated under the Clean Air Act. This document is supplied as an appendix to the application, Idaho National Laboratory Application for a Synthetic Minor Sitewide Air Quality Permit to Construct with a Facility Emissions Cap Component, hereafter referred to as “permit application” (DOE-ID 2015). Air dispersion modeling was performed as part of the permit application process to demonstrate pollutant emissions from the INL will not cause a violation of any ambient air quality standards. This report documents the modeling methodology and results for the air dispersion impact analysis. All CAPs regulated under Section 109 of the Clean Air Act were modeled with the exception of lead (Pb) and ozone, which are not required to be modeled by DEQ. Modeling was not performed for toxic air pollutants (TAPs) as uncontrolled emissions did not exceed screening emission levels for carcinogenic and non-carcinogenic TAPs. Modeling for CAPs was performed with the EPA approved AERMOD dispersion modeling system (Version 14134) (EPA 2004a) and five years (2000-2004) of meteorological data. The meteorological data set was produced with the companion AERMET model (Version 14134) (EPA 2004b) using surface data from the Idaho Falls airport, and upper-air data from Boise International Airport supplied by DEQ. Onsite meteorological data from the Grid 3 Mesonet tower located near the center of the INL (north of INTEC) and supplied by the local National Oceanic and Atmospheric Administration (NOAA) office was used for surface wind directions and wind speeds. Surface data (i

  9. Cold plasmas

    Franz, G.

    1990-01-01

    This textbook discusses the following topics: Phenomenological description of a direct current glow discharge; the plasma (temperature distribution and measurement, potential variation, electron energy distribution function, charge neutralization, wall potentials, plasma oscillations); Production of charge carriers (ions, electrons, ionization in the cathode zone, negative glowing zone, Faraday dark space, positive column, anode zone, hollow cathode discharges); RF-discharges (charge carrier production, RF-Shields, scattering mechanisms); Sputtering (ion-surface interaction, kinetics, sputtering yield and energy distribution, systems and conditions, film formation and stresses, contamination, bias techniques, multicomponent film deposition, cohesion, magnetrons, triode systems, plasma enhanced chemical vapor deposition); Dry etching (sputter etching, reactive etching, topography, process control, quantitative investigations); Etching mechanisms (etching of Si and SiO 2 with CF 4 , of III/V-compound-semiconductors, combination of isotrope and anisotrope etching methods, surface cleaning); ion beam systems (applications, etching); Dyclotron-resonance-systems (electron cyclotron resonance systems, whistler-sources and 'resonant inductive plasma etching'); Appendix (electron energy distribution functions, Bohm's transition zone, plasma oscillations, scattering cross sections and mean free path, metastable states, Child-Langmuir-Schottky equation, loss mechanisms, charge carrier distribution in the positive column, breakdown at high frequencies, motion in a magnetic field, skin depth of an electric field for a HF-discharge, whistler waves, dispersion relations for plane wave propagation). (orig.) With 138 figs

  10. "Choice of Air Cargo Transshipment Airport: An Application to Air Cargo Traffic to/from Northeast Asia"

    Hiroshi Ohashi; Tae-Seung Kim; Tae Hoon Oum; Chunyan Yu

    2004-01-01

    Based on a unique data set of 760 air cargo transshipment routings to/from the Northeast Asian region in 2000, this paper applies an aggregate form of multinomial logit model to identify the critical factors influencing air cargo transshipment route choice decisions. The analysis focuses on the trade-off between monetary cost and time cost while considering other variables relevant for choice of transshipment airport. The estimation method considers the presence of unobserved attributes, and ...

  11. Spectroscopic Challenges in the Modelling and Diagnostics of High Temperature Air Plasma Radiation for Aerospace Applications

    Laux, Christophe O.

    2007-01-01

    State-of-the-art spectroscopic models of the radiative transitions of interest for Earth re-entry and ground-based diagnostic facilities for aerospace applications are reviewed. The spectral range considered extends from the vacuum ultraviolet to the mid-infrared range (80 nm to 5.5 μm). The modeling results are compared with absolute intensity measurements of the ultraviolet-visible-infrared emission of a well-characterized high-temperature air plasma produced with a 50 kW inductively coupled radio-frequency plasma torch, and with high-resolution absorption spectra from the Center for Astrophysics in the vacuum ultraviolet. The Spectroscopic data required to better model the spectral features of interest for aerospace applications are discussed

  12. Statistics of work and orthogonality catastrophe in discrete level systems: an application to fullerene molecules and ultra-cold trapped Fermi gases

    Antonello Sindona

    2015-03-01

    Full Text Available The sudden introduction of a local impurity in a Fermi sea leads to an anomalous disturbance of its quantum state that represents a local quench, leaving the system out of equilibrium and giving rise to the Anderson orthogonality catastrophe. The statistics of the work done describe the energy fluctuations produced by the quench, providing an accurate and detailed insight into the fundamental physics of the process. We present here a numerical approach to the non-equilibrium work distribution, supported by applications to phenomena occurring at very diverse energy ranges. One of them is the valence electron shake-up induced by photo-ionization of a core state in a fullerene molecule. The other is the response of an ultra-cold gas of trapped fermions to an embedded two-level atom excited by a fast pulse. Working at low thermal energies, we detect the primary role played by many-particle states of the perturbed system with one or two excited fermions. We validate our approach through the comparison with some photoemission data on fullerene films and previous analytical calculations on harmonically trapped Fermi gases.

  13. Conceptualizing Cold Disasters

    Lauta, Kristian Cedervall; Dahlberg, Rasmus; Vendelø, Morten Thanning

    2017-01-01

    In the present article, we explore in more depth the particular circumstances and characteristics of governing what we call ‘cold disasters’, and thereby, the paper sets out to investigate how disasters in cold contexts distinguish themselves from other disasters, and what the implications hereof...... are for the conceptualization and governance of cold disasters. Hence, the paper can also be viewed as a response to Alexander’s (2012a) recent call for new theory in the field of disaster risk reduction. The article is structured in four overall parts. The first part, Cold Context, provides an overview of the specific...... conditions in a cold context, exemplified by the Arctic, and zooms in on Greenland to provide more specific background for the paper. The second part, Disasters in Cold Contexts, discusses “cold disasters” in relation to disaster theory, in order to, elucidate how cold disasters challenge existing...

  14. Working in the Cold

    During the winter, many workers are outdoors, working in cold, wet, icy, or snowy conditions. Learn how to identify symptoms that tell you there may be a problem and protect yourself from cold stress.

  15. Colds and the Flu

    ... disease (COPD). What medicines can I give my child? There is no cure for the cold or the flu, and antibiotics do not work against the viruses that cause colds and the flu. Pain relievers such as ...

  16. Cold knife cone biopsy

    ... biopsy; Pap smear - cone biopsy; HPV - cone biopsy; Human papilloma virus - cone biopsy; Cervix - cone biopsy; Colposcopy - cone biopsy Images Female reproductive anatomy Cold cone biopsy Cold cone removal References Baggish ...

  17. Cold medicines and children

    ... ingredient. Avoid giving more than one OTC cold medicine to your child. It may cause an overdose with severe side ... the dosage instructions strictly while giving an OTC medicine to your child. When giving OTC cold medicines to your child: ...

  18. Case-Crossover Analysis of Air Pollution Health Effects: A Systematic Review of Methodology and Application

    Carracedo-Martínez, Eduardo; Taracido, Margarita; Tobias, Aurelio; Saez, Marc; Figueiras, Adolfo

    2010-01-01

    Background Case-crossover is one of the most used designs for analyzing the health-related effects of air pollution. Nevertheless, no one has reviewed its application and methodology in this context. Objective We conducted a systematic review of case-crossover (CCO) designs used to study the relationship between air pollution and morbidity and mortality, from the standpoint of methodology and application. Data sources and extraction A search was made of the MEDLINE and EMBASE databases. Reports were classified as methodologic or applied. From the latter, the following information was extracted: author, study location, year, type of population (general or patients), dependent variable(s), independent variable(s), type of CCO design, and whether effect modification was analyzed for variables at the individual level. Data synthesis The review covered 105 reports that fulfilled the inclusion criteria. Of these, 24 addressed methodological aspects, and the remainder involved the design’s application. In the methodological reports, the designs that yielded the best results in simulation were symmetric bidirectional CCO and time-stratified CCO. Furthermore, we observed an increase across time in the use of certain CCO designs, mainly symmetric bidirectional and time-stratified CCO. The dependent variables most frequently analyzed were those relating to hospital morbidity; the pollutants most often studied were those linked to particulate matter. Among the CCO-application reports, 13.6% studied effect modification for variables at the individual level. Conclusions The use of CCO designs has undergone considerable growth; the most widely used designs were those that yielded better results in simulation studies: symmetric bidirectional and time-stratified CCO. However, the advantages of CCO as a method of analysis of variables at the individual level are put to little use. PMID:20356818

  19. A coupled factorial-analysis-based interval programming approach and its application to air quality management.

    Wang, S; Huang, G H

    2013-02-01

    In this study, a coupled factorial-analysis-based interval programming (CFA-IP) approach is developed through incorporating factorial analysis within an interval-parameter linear programming framework. CFA-IP can tackle uncertainties presented as intervals that exist in the objective function and the left- and right-hand sides of constraints, as well as robustly reflect interval information in the solutions for the objective-function value and decision variables. Moreover CFA-IP has the advantage of investigating the potential interactions among input parameters and their influences on lower- and upper-bound solutions, which is meaningful for supporting an in-depth analysis of uncertainty. A regional air quality management problem is studied to demonstrate applicability of the proposed CFA-IP approach. The results indicate that useful solutions have been generated for planning the air quality management practices. They can help decision makers identify desired pollution mitigation strategies with minimized total cost and maximized environmental efficiency, as well as screen out dominant parameters and explore the valuable information that may be veiled beneath their interrelationships. The CFA-IP approach can not only tackle uncertainties presented as intervals that exist in the objective function and the left- and right-hand sides of constraints, but also investigate their interactive effects on model outputs, which is meaningful for supporting an in-depth analysis of uncertainty. Thus CFA-IP would be applicable to air quality management problems under uncertainty. The results obtained from CFA-IP can help decision makers identify desired pollution mitigation strategies, as well as investigate the potential interactions among factors and analyze their consequent effects on modeling results.

  20. Air source absorption heat pump in district heating: Applicability analysis and improvement options

    Wu, Wei; Shi, Wenxing; Li, Xianting; Wang, Baolong

    2015-01-01

    Highlights: • Applicability of air source absorption heat pump (ASAHP) district heating is studied. • Return temperature and energy saving rate (ESR) in various conditions are optimized. • ASAHP is more suitable for shorter distance or lower temperature district heating. • Two options can reduce the primary return temperature and improve the applicability. • The maximum ESR is improved from 13.6% to 20.4–25.6% by compression-assisted ASAHP. - Abstract: The low-temperature district heating system based on the air source absorption heat pump (ASAHP) was assessed to have great energy saving potential. However, this system may require smaller temperature drop leading to higher pump consumption for long-distance distribution. Therefore, the applicability of ASAHP-based district heating system is analyzed for different primary return temperatures, pipeline distances, pipeline resistances, supplied water temperatures, application regions, and working fluids. The energy saving rate (ESR) under different conditions are calculated, considering both the ASAHP efficiency and the distribution consumption. Results show that ASAHP system is more suitable for short-distance district heating, while for longer-distance heating, lower supplied hot water temperature is preferred. In addition, the advantages of NH 3 /H 2 O are inferior to those of NH 3 /LiNO 3 , and the advantages for warmer regions and lower pipeline resistance are more obvious. The primary return temperatures are optimized to obtain maximum ESRs, after which the suitable distances under different acceptable ESRs are summarized. To improve the applicability of ASAHP, the integration of cascaded heat exchanger (CHX) and compression-assisted ASAHP (CASAHP) are proposed, which can reduce the primary return temperature. The integration of CHX can effectively improve the applicability of ASAHP under higher supplied water temperatures. As for the utilization of CASAHP, higher compression ratio (CR) is better in

  1. The application of lichens as ecological surrogates of air pollution in the subtropics: a case study in South Brazil.

    Koch, Natália M; Branquinho, Cristina; Matos, Paula; Pinho, Pedro; Lucheta, Fabiane; Martins, Suzana M A; Vargas, Vera M F

    2016-10-01

    The use of lichens as ecological surrogates has been an important tool to evaluate the impact of air pollution in both ecosystem and human health but remains underused in the subtropics due to lack of knowledge. Aiming to support the application of lichen as ecological surrogates of the effects of air pollution in the subtropics, we hypothesized that urbanization was an important driver of changes on lichen diversity, composition, and vitality. For that, we quantified several lichen diversity metrics (richness, cover, and community composition) and photobiont vitality in relation to atmospheric pollution or its surrogates (modeled pollutant gases, pollutants in lichen thallus, and land cover). We confirmed that air pollution was a key driver for lichen diversity. Changes in lichen community composition and vitality were very significantly related to air pollution and integrated the effect of multiple stressors (particulate matter, NOx, and Cu), thus being powerful ecological indicators of air pollution in the subtropics.

  2. Feasibility study on novel room air conditioner with natural cooling capability

    Han, Zongwei; Liu, Qiankun; Zhang, Yanqing; Zhang, Shuwei; Liu, Jiangzhen; Li, Weiliang

    2016-01-01

    Highlights: • A novel heat pipe combined evaporative cooling room air conditioner is constructed. • The mathematical model of the air conditioner is established. • The reliability of the model is verified by experiments. • The performance of the novel and conventional air conditioner is compared. • The applicability of the novel air conditioner in different areas is investigated. - Abstract: In order to improve the energy efficiency of room air conditioners, this paper proposed a new air conditioner that combined evaporative cooling technology, separate type heat pipe technology, and vapour compression refrigeration technology (called “combined air conditioner”). The mathematical model of the air conditioner was established and its reliability was verified by experiments. Based on the model, the simulation of the operating performance of the combined air conditioner and a conventional air conditioner was studied in typical climate regions during the cooling period, with the following results: In cold and dry areas like Shenyang, compared with the conventional air conditioner, the average cooling coefficient of performance (COP) of the combined air conditioner was increased by 27.40%. As the climate gradually became warmer and humidity gradually increased, the running time of the heat pipe cooling mode was gradually reduced, and then the energy-saving effect of the combined air conditioner became worse. For example, in the hot and humid Guangzhou, the energy saving rate was only 11.81%. Therefore, it was found that the combined air conditioner had good energy-saving potential in cold and dry areas.

  3. Air conditioning and power generation for residential applications using liquid nitrogen

    Ahmad, Abdalqader; Al-Dadah, Raya; Mahmoud, Saad

    2016-01-01

    Highlights: • Using liquid nitrogen to provide power and air conditioning for domestic applications. • The proposed system leads to save energy and reduce the peak electricity demands. • Compared with conventional AC saving up to 36% was achieved at the current LN2 price. • The widespread of this technology leads to lower LN2 price and saving up to 81%. • The last configuration was the efficient system with overall thermal efficiency 74%. - Abstract: Current air conditioning (AC) systems consume a significant amount of energy, particularly during peak times where most electricity suppliers face difficulties to meet the users’ demands, and the global demands for AC systems have increased rapidly over the last few decades leading to significant power consumption and carbon dioxide emissions. This paper presents a new technique that uses liquid nitrogen (LN2) produced from renewable energy sources, or surplus electricity at off peak times, to provide cooling and power for domestic houses. Thermodynamic analyses of various cryogenic cycles have been carried out to achieve the most effective configuration that produces the maximum power output with minimum LN2 flow rate, to meet the required cooling of a 170 m"2 dwelling in Libya. A comparison with a conventional AC system was also made. Results showed that at the current LN2 prices, using LN2 to provide cooling and power demands of residential buildings is feasible and saves up to 36% compared to conventional air conditioning systems with an overall thermal efficiency of 74%. However, as the LN2 price decreases to around 1.3 pence per kg, the proposed technology will have significant advantages compared to conventional AC systems with savings of up to 81%.

  4. How cold is cold dark matter?

    Armendariz-Picon, Cristian; Neelakanta, Jayanth T.

    2014-01-01

    If cold dark matter consists of particles, these must be non-interacting and non-relativistic by definition. In most cold dark matter models however, dark matter particles inherit a non-vanishing velocity dispersion from interactions in the early universe, a velocity that redshifts with cosmic expansion but certainly remains non-zero. In this article, we place model-independent constraints on the dark matter temperature to mass ratio, whose square root determines the dark matter velocity dispersion. We only assume that dark matter particles decoupled kinetically while non-relativistic, when galactic scales had not entered the horizon yet, and that their momentum distribution has been Maxwellian since that time. Under these assumptions, using cosmic microwave background and matter power spectrum observations, we place upper limits on the temperature to mass ratio of cold dark matter today (away from collapsed structures). These limits imply that the present cold dark matter velocity dispersion has to be smaller than 54 m/s. Cold dark matter has to be quite cold, indeed

  5. [Experimental study on two-way application of traditional Chinese medicines capable of promoting blood circulation and removing blood stasis with neutral property in cold and hot blood stasis syndrome I].

    Hao, Er-Wei; Deng, Jia-Gang; Du, Zheng-Cai; Yan, Ke; Zheng, Zuo-Wen; Wang, Qin; Huang, Li-Zhen; Bao, Chuan-Hong; Deng, Xiu-Qiong; Lu, Xiao-Yan; Tang, Zhi-Ling

    2012-11-01

    To study the action characteristics of "two-way application and conditioned dominance" of traditional Chinese medicines with neutral property by observing the action characteristic of 10 traditional Chinese medicines capable of promoting blood circulation and removing blood stasis with neutral property in the microcirculation in rats with heat stagnation and blood stasis syndrome. The rat model with heat stagnation and blood stasis syndrome was established by injecting carrageenan and dry yeast, and the rat model with cold stagnation and blood stasis syndrome was built by the body freezing method. Ten traditional Chinese medicines with neutral property, including 5 with hot property and 5 with cold property, were selected for intervention to observe blood flow rate and flow state indicators in rat auricles and make a comparative analysis on action characteristics of traditional Chinese medicines with neutral property. ANOVA showed that among the 10 traditional Chinese medicines with neutral property, 6 such as Typhae Pollen, Sappan Lignum and Vaccariae Semen can obviously increase the blood flow rate (P traditional Chinese medicines with cold property can increase the blood flow rate (P medicines showed no notable effect; among the 5 traditional Chinese medicines with hot property, Carthamus tinctorius and Ligusticum chuanxiong can increase the blood flow rate (P traditional Chinese medicines with natural and cold properties showed similar effect on heat stagnation and blood stasis syndrome and better effect in increasing blood flow rate than those with hot property; those with natural and hot properties showed similar effect and better effect in increasing blood flow rate than those with cold property. Under the condition of heat stagnation and blood stasis syndrome, traditional Chinese medicines with neutral property have the similar action characteristics with those with cold property; wile under the condition of cold stagnation and blood stasis syndrome

  6. Electrical discharge machining of carbon nanomaterials in air: machining characteristics and the advanced field emission applications

    Ok, Jong Girl; Kim, Bo Hyun; Chung, Do Kwan; Sung, Woo Yong; Lee, Seung Min; Lee, Se Won; Kim, Wal Jun; Park, Jin Woo; Chu, Chong Nam; Kim, Yong Hyup

    2008-01-01

    A reliable and precise machining process, electrical discharge machining (EDM), was investigated in depth as a novel method for the engineering of carbon nanomaterials. The machining characteristics of EDM applied to carbon nanomaterials 'in air' were systematically examined using scanning electron microscopy (SEM), high-resolution transmission electron microscopy (HR-TEM), energy-dispersive x-ray spectroscopy (EDS), x-ray photoelectron spectroscopy (XPS) and Raman spectroscopy. The EDM process turned out to 'melt' carbon nanomaterials with the thermal energy generated by electrical discharge, which makes both the materially and geometrically unrestricted machining of nanomaterials possible. Since the EDM process conducted in air requires neither direct contact nor chemical agents, it protects the carbon nanomaterial workpieces against physical damage and unnecessary contamination. From this EDM method, several advanced field emission applications including 'top-down' patterning and the creative lateral comb-type triode device were derived, while our previously reported study on emission uniformity enhancement by the EDM method was also referenced. The EDM method has great potential as a clean, effective and practical way to utilize carbon nanomaterials for various uses

  7. Monitoring Effective Doses Received By Air Crews With A Space Weather Application

    Lantos, P.

    To fulfil new requirements of the European Community concerning monitoring of effective doses received by air crews, the French Aviation Authority has developed an operational system called Sievert. The SIEVERT system is analysed as an exam- ple of Space Weather application. One of its characteristics is to calculate the dose received on-board each flight on the basis of the specific and detailled flight given by companies. Operational models will be used. As input to the models, the system needs monitoring of galactic cosmic rays and of solar flare particles. The French neu- tron monitors located in Kerguelen Islands (South Indian Ocean) and Terre Adélie (Antarctica) will be used for this purpose. Particular attention will be devoted to evo- lution of the system in conjunction with new measurements available in the frame of a permanent validation process.

  8. Application of Steinbuch's ''lernmatrix'' as a new mathematical approach in the assessment of air pollution effects

    Prinz, B [Landesanstalt fuer Immissions- und Bodennutzungsschutz des Landes Nordrhein-Westfalen, Essen; Hower, J

    1976-01-01

    Special investigations are being carried out on the effects of airborne lead on children, as part of a comprehensive surveillance system of air pollution effects on materials and biological receptors in the land Northrhine Westphalia. This study is executed in two stages. Firstly, blood lead of new-borns is compared with measures of airborne lead at the mother's place of residence. From this comparison a correlation of r/sup 2/ = 0.40 was ascertained. Secondly, highly burdened children are selected and investigated for possible neurological retardation during their first year after birth. For this investigation, which is now under way in the Duisburg area, a newly developed technique is applied that is based on a standardized method for eliciting and categorizing infantile reflex patterns. The reduction of the resulting multivariate neurological profiles to an uniform scale of developmental age and the comparison to some reference group is carried out by the application of Steinbuch's Lernmatrix (learning matrix).

  9. Comparison and application study on cosmic radiation dose calculation received by air crew

    Zhou Qiang; Xu Cuihua; Ren Tianshan; Li Wenhong; Zhang Jing; Lu Xu

    2009-01-01

    Objective: To facilitate evaluation on Cosmic radiation dose received by flight crew by developing a convenient and effective measuring method. Methods: In comparison with several commonly used evaluating methods, this research employs CARI-6 software issued by FAA (Federal Aviation Administration) to measure Cosmic radiation dose for flight crew members exposed to. Results: Compared with other methods, CARI-6 is capable of providing reliable calculating results on radiation dose and applicable to all flight crew of different airlines. Conclusion: Cosmic radiation received by flight crew is on the list of occupational radiation. For a smooth running of Standards for controlling exposure to cosmic radiation of air crew, CARI software may be a widely applied tool in radiation close estimation of for flight crew. (authors)

  10. A Study on the Potential Applications of Satellite Data in Air Quality Monitoring and Forecasting

    Li, Can; Hsu, N. Christina; Tsay, Si-Chee

    2011-01-01

    In this study we explore the potential applications of MODIS (Moderate Resolution Imaging Spectroradiometer) -like satellite sensors in air quality research for some Asian regions. The MODIS aerosol optical thickness (AOT), NCEP global reanalysis meteorological data, and daily surface PM(sub 10) concentrations over China and Thailand from 2001 to 2009 were analyzed using simple and multiple regression models. The AOT-PM(sub 10) correlation demonstrates substantial seasonal and regional difference, likely reflecting variations in aerosol composition and atmospheric conditions, Meteorological factors, particularly relative humidity, were found to influence the AOT-PM(sub 10) relationship. Their inclusion in regression models leads to more accurate assessment of PM(sub 10) from space borne observations. We further introduced a simple method for employing the satellite data to empirically forecast surface particulate pollution, In general, AOT from the previous day (day 0) is used as a predicator variable, along with the forecasted meteorology for the following day (day 1), to predict the PM(sub 10) level for day 1. The contribution of regional transport is represented by backward trajectories combined with AOT. This method was evaluated through PM(sub 10) hindcasts for 2008-2009, using ohservations from 2005 to 2007 as a training data set to obtain model coefficients. For five big Chinese cities, over 50% of the hindcasts have percentage error less than or equal to 30%. Similar performance was achieved for cities in northern Thailand. The MODIS AOT data are responsible for at least part of the demonstrated forecasting skill. This method can be easily adapted for other regions, but is probably most useful for those having sparse ground monitoring networks or no access to sophisticated deterministic models. We also highlight several existing issues, including some inherent to a regression-based approach as exemplified by a case study for Beijing, Further studies will be

  11. Efficient synthesis of superparamagnetic magnetite nanoparticles under air for biomedical applications

    Saxena, Namita, E-mail: saxenanamita@yahoo.com [School of Nano Sciences, Central University of Gujarat, Gandhinagar 382030 (India); Singh, Man, E-mail: mansingh50@hotmail.com [School of Chemical Sciences, Central University of Gujarat, Gandhinagar 382030 (India)

    2017-05-01

    The facile co-precipitation process of synthesising Superparamagnetic Iron Oxide Nanoparticles (SPIONs) especially magnetite was investigated and simplified, to develop a reproducible and scaled up synthesis process under air, for producing particles with enhanced percentage of magnetite, thus eliminating the crucial and complicated need of using the inert atmosphere. Presence of magnetite was confirmed by XRD, TEM, and Raman spectroscopy. Efficiency of synthesising magnetite was increased up to approx. ∼58 wt%, under air with no other phases but maghemite present. Alkali concentration was optimised, and particles with better magnetisation values were synthesised. The approximate weight percentage of magnetite was calculated using the simple and rapid XRD peak deconvolution method. Higher pH values from 13 to14 were investigated in the study while alkali concentration was varied from 0.5 to 4 M. 1Molar NaOH with a final pH of 13.4 was found to be optimum. Well crystallised particles with approx. 6–12 nm size, narrow size distribution and cubo-spheroidal shape were synthesised. Particles were Superparamagnetic with high values of saturation magnetisation of up to 68 emu/g and negligible values of remanence and coercivity. A reaction yield of up to 62% was obtained. Hydrophilic coated particles were produced in a single, one step facile process for biomedical applications, using optimised parameters of pH and alkali concentration obtained in the study. Single domain particles with good magnetisation formed stable aqueous dispersions. FTIR, UV-Visible and DLS were used to confirm the coating and dispersion stabilities of the particles. These particles have the requisite properties required for application in different biomedical fields.

  12. Application of acoustic agglomeration to enhance air filtration efficiency in air-conditioning and mechanical ventilation (ACMV) systems

    Ng, Bing Feng; Xiong, Jin Wen; Wan, Man Pun

    2017-01-01

    The recent episodes of haze in Southeast Asia have caused some of the worst regional atmospheric pollution ever recorded in history. In order to control the levels of airborne fine particulate matters (PM) indoors, filtration systems providing high PM capturing efficiency are often sought, which inadvertently also results in high airflow resistance (or pressure drop) that increases the energy consumption for air distribution. A pre-conditioning mechanism promoting the formation of particle cl...

  13. SU-E-T-297: Dosimetric Assessment of An Air-Filled Balloon Applicator in HDR Vaginal Cuff Brachytherapy Using the Monte Carlo Method

    Jiang, H; Lee, Y; Pokhrel, D; Badkul, R [University of Kansas Hospital, Kansas City, KS (United States)

    2015-06-15

    Purpose: As an alternative to cylindrical applicators, air inflated balloon applicators have been introduced into HDR vaginal cuff brachytherapy treatment to achieve sufficient dose to vagina mucosa as well as to spare rectum and bladder. In general, TG43 formulae based treatment planning systems do not take into account tissue inhomogeneity, and air in the balloon applicator can cause higher delivered dose to mucosa than treatment plan reported. We investigated dosimetric effect of air in balloon applicator using the Monte Carlo method. Methods: The thirteen-catheter Capri applicator with a Nucletron Ir-192 seed was modeled for various balloon diameters (2cm to 3.5cm) using the MCNP Monte Carlo code. Ir-192 seed was placed in both central and peripheral catheters to replicate real patient situations. Existence of charged particle equilibrium (CPE) with air balloon was evaluated by comparing kerma and dose at various distances (1mm to 70mm) from surface of air-filled applicator. Also mucosa dose by an air-filled applicator was compared with by a water-filled applicator to evaluate dosimetry accuracy of planning system without tissue inhomogeneity correction. Results: Beyond 1mm from air/tissue interface, the difference between kerma and dose was within 2%. CPE (or transient CPE) condition was deemed existent, and in this region no electron transport was necessary in Monte Carlo simulations. At 1mm or less, the deviation of dose from kerma became more apparent. Increase of dose to mucosa depended on diameter of air balloon. The increment of dose to mucosa was 2.5% and 4.3% on average for 2cm and 3.5cm applicators, respectively. Conclusion: After introduction of air balloon applicator, CPE fails only at the proximity of air/tissue interface. Although dose to mucosa is increased, there is no significant dosimetric difference (<5%) between air and water filled applicators. Tissue inhomogeneity correction is not necessary for air-filled applicators.

  14. SU-E-T-297: Dosimetric Assessment of An Air-Filled Balloon Applicator in HDR Vaginal Cuff Brachytherapy Using the Monte Carlo Method

    Jiang, H; Lee, Y; Pokhrel, D; Badkul, R

    2015-01-01

    Purpose: As an alternative to cylindrical applicators, air inflated balloon applicators have been introduced into HDR vaginal cuff brachytherapy treatment to achieve sufficient dose to vagina mucosa as well as to spare rectum and bladder. In general, TG43 formulae based treatment planning systems do not take into account tissue inhomogeneity, and air in the balloon applicator can cause higher delivered dose to mucosa than treatment plan reported. We investigated dosimetric effect of air in balloon applicator using the Monte Carlo method. Methods: The thirteen-catheter Capri applicator with a Nucletron Ir-192 seed was modeled for various balloon diameters (2cm to 3.5cm) using the MCNP Monte Carlo code. Ir-192 seed was placed in both central and peripheral catheters to replicate real patient situations. Existence of charged particle equilibrium (CPE) with air balloon was evaluated by comparing kerma and dose at various distances (1mm to 70mm) from surface of air-filled applicator. Also mucosa dose by an air-filled applicator was compared with by a water-filled applicator to evaluate dosimetry accuracy of planning system without tissue inhomogeneity correction. Results: Beyond 1mm from air/tissue interface, the difference between kerma and dose was within 2%. CPE (or transient CPE) condition was deemed existent, and in this region no electron transport was necessary in Monte Carlo simulations. At 1mm or less, the deviation of dose from kerma became more apparent. Increase of dose to mucosa depended on diameter of air balloon. The increment of dose to mucosa was 2.5% and 4.3% on average for 2cm and 3.5cm applicators, respectively. Conclusion: After introduction of air balloon applicator, CPE fails only at the proximity of air/tissue interface. Although dose to mucosa is increased, there is no significant dosimetric difference (<5%) between air and water filled applicators. Tissue inhomogeneity correction is not necessary for air-filled applicators

  15. Development of a High-Resolution Laser Absorption Spectroscopy Method with Application to the Determination of Absolute Concentration of Gaseous Elemental Mercury in Air.

    Srivastava, Abneesh; Hodges, Joseph T

    2018-05-07

    Isotope dilution-cold-vapor-inductively coupled plasma mass spectrometry (ID-CV-ICPMS) has become the primary standard for measurement of gaseous elemental mercury (GEM) mass concentration. However, quantitative mass spectrometry is challenging for several reasons including (1) the need for isotopic spiking with a standard reference material, (2) the requirement for bias-free passive sampling protocols, (3) the need for stable mass spectrometry interface design, and (4) the time and cost involved for gas sampling, sample processing, and instrument calibration. Here, we introduce a high-resolution laser absorption spectroscopy method that eliminates the need for sample-specific calibration standards or detailed analysis of sample treatment losses. This technique involves a tunable, single-frequency laser absorption spectrometer that measures isotopically resolved spectra of elemental mercury (Hg) spectra of 6 1 S 0 ← 6 3 P 1 intercombination transition near λ = 253.7 nm. Measured spectra are accurately modeled from first-principles using the Beer-Lambert law and Voigt line profiles combined with literature values for line positions, line shape parameters, and the spontaneous emission Einstein coefficient to obtain GEM mass concentration values. We present application of this method for the measurement of the equilibrium concentration of mercury vapor near room temperature. Three closed systems are considered: two-phase mixtures of liquid Hg and its vapor and binary two-phase mixtures of Hg-air and Hg-N 2 near atmospheric pressure. Within the experimental relative standard uncertainty, 0.9-1.5% congruent values of the equilibrium Hg vapor concentration are obtained for the Hg-only, Hg-air, Hg-N 2 systems, in confirmation with thermodynamic predictions. We also discuss detection limits and the potential of the present technique to serve as an absolute primary standard for measurements of gas-phase mercury concentration and isotopic composition.

  16. The Evolution of Successful Satellite Science to Air Quality Application Projects: From Inception to Realization

    Soja, A. J.

    2012-12-01

    Teams of scientist have been working for almost a decade with state, local, regional and federal Air Quality regulators and scientists on several projects that have been focused on improving biomass burning emissions within our nation's National Emissions Inventory (NEI). Initially, the NEI was based strictly on ground-based information that often used data aggregated from previous years reported at the county-centroid and completely ignored the spatial domain of all fires. This methodology resulted in gross inaccuracies; however it was an ingrained system and the users and organizations were largely comfortable. Improvements were viewed as too costly. Our task was to convince regulators, managers and users of the value that could be added by using satellite data to enhance the NEI. Certainly, there were individuals that understood the value of using satellite data, but they needed support to convince the establishment of the intrinsic, cost-effective value of publically-available satellite data. It was essential to present arguments, as well as requested verification and validation statistics, in the format that most suited the objectives of application organizations. This process incorporated: knowledge of state-of-the-art satellite data, algorithms and science; a working knowledge of the users applications and requirements; interacting with individuals with a variety of skill sets and goals; and perhaps most importantly, listening to the goals and responsibilities of the user community and fully communicating. Today, the Environmental Protection Agency and several state and regional organizations are using satellite data to estimate biomass burnings emissions at daily and annual scales for a number of critical environmental management and policy activities including regulation setting and regional strategy development for attainment of the National Ambient Air Quality Standards (NAAQS). We continue to work at the local, state and federal levels to improve the

  17. Statistical Correction of Air Temperature Forecasts for City and Road Weather Applications

    Mahura, Alexander; Petersen, Claus; Sass, Bent; Gilet, Nicolas

    2014-05-01

    The method for statistical correction of air /road surface temperatures forecasts was developed based on analysis of long-term time-series of meteorological observations and forecasts (from HIgh Resolution Limited Area Model & Road Conditions Model; 3 km horizontal resolution). It has been tested for May-Aug 2012 & Oct 2012 - Mar 2013, respectively. The developed method is based mostly on forecasted meteorological parameters with a minimal inclusion of observations (covering only a pre-history period). Although the st iteration correction is based taking into account relevant temperature observations, but the further adjustment of air and road temperature forecasts is based purely on forecasted meteorological parameters. The method is model independent, e.g. it can be applied for temperature correction with other types of models having different horizontal resolutions. It is relatively fast due to application of the singular value decomposition method for matrix solution to find coefficients. Moreover, there is always a possibility for additional improvement due to extra tuning of the temperature forecasts for some locations (stations), and in particular, where for example, the MAEs are generally higher compared with others (see Gilet et al., 2014). For the city weather applications, new operationalized procedure for statistical correction of the air temperature forecasts has been elaborated and implemented for the HIRLAM-SKA model runs at 00, 06, 12, and 18 UTCs covering forecast lengths up to 48 hours. The procedure includes segments for extraction of observations and forecast data, assigning these to forecast lengths, statistical correction of temperature, one-&multi-days statistical evaluation of model performance, decision-making on using corrections by stations, interpolation, visualisation and storage/backup. Pre-operational air temperature correction runs were performed for the mainland Denmark since mid-April 2013 and shown good results. Tests also showed

  18. Applications of the three-dimensional air quality system to western U.S. air quality: IDEA, smog blog, smog stories, airquest, and the remote sensing information gateway.

    Hoff, Raymond; Zhang, Hai; Jordan, Nikisa; Prados, Ana; Engel-Cox, Jill; Huff, Amy; Weber, Stephanie; Zell, Erica; Kondragunta, Shobha; Szykman, James; Johns, Brad; Dimmick, Fred; Wimmers, Anthony; Al-Saadi, Jay; Kittaka, Chieko

    2009-08-01

    A system has been developed to combine remote sensing and ground-based measurements of aerosol concentration and aerosol light scattering parameters into a three-dimensional view of the atmosphere over the United States. Utilizing passive and active remote sensors from space and the ground, the system provides tools to visualize particulate air pollution in near real time and archive the results for retrospective analyses. The main components of the system (Infusing satellite Data into Environmental Applications [IDEA], the U.S. Air Quality Weblog [Smog Blog], Smog Stories, U.S. Environmental Protection Agency's AIRQuest decision support system, and the Remote Sensing Information Gateway [RSIG]) are described, and the relationship of how data move from one system to another is outlined. To provide examples of how the results can be used to analyze specific pollution episodes, three events (two fires and one wintertime low planetary boundary layer haze) are discussed. Not all tools are useful at all times, and the limitations, including the sparsity of some data, the interference caused by overlying clouds, etc., are shown. Nevertheless, multiple sources of data help a state, local, or regional air quality analyst construct a more thorough picture of a daily air pollution situation than what one would obtain with only surface-based sensors.

  19. Cold formability of steels

    Lafond, G.; Leclerq, G.; Moliexe, F.; Namdar, R.; Roesch, L.; Sanz, G.

    1977-01-01

    This work was essentially aimed to the study of the following three questions. Is it possible to assess the cold formability of steels using simple material properties as criteria. What values of mechanical properties can one expect to reach in cold formed parts. Are there simple ways of characterizing the speroidization treatments carried out on steels before cold forming operations. The present report describes the results obtained during this investigation. It is logically divided into three separate parts. Experimental study of cold formability in wire drawing. Influence of metallurgical variables on mechanical properties of high carbon cold drawn wires. Contribution to the study of characterization methods of cold forming steels subjected to a spheroidization heat treatment

  20. Alpha radioactivity measurement technology with ionized air type measurement. Applicability evaluation to verification of the clearance level

    Mita, Yutaka; Matsumura, Toshihiro; Yokoyama, Kaoru; Sugitsue, Noritake

    2008-10-01

    The purpose of this test is to evaluate the applicability of the clearance level measuring system by Ionized Air Type Measurement after decontaminated by sulfuric acid sample. In Ningyo-toge Environmental Engineering Center. The equipment and radioactive waste which were contaminated with uranium are generated so much in future dismantling stage. In our plan, some of equipments and radioactive waste are contaminated to a clearance level, and cut down on decommission and disposal expense. This plan needs the alpha-rays measurement technology of the very low level. We think that ionized Air transfer measurement technology is promising as of clearance verification technology. The ionized Air transfer measurement technology applied to the Ionized Air Type Measurement can measure plan radioactivity of a very low level. Moreover, as compared with a direct survey, there is the merit which can be measured in a short time. However ionized Air transfer measurement technology is new technology. Therefore, there is almost no measurement track record. Furthermore, the date about the influence of a background, a detection limit, measurement performance, and reliability is insufficient. So, this measurement test estimated applicability as clearance level verification of an Ionized Air Type Measurement. (author)

  1. Constructing an AIRS Climatology for Data Visualization and Analysis to Serve the Climate Science and Application Communities

    Ding, Feng; Keim, Elaine; Hearty, Thomas J.; Wei, Jennifer; Savtchenko, Andrey; Theobald, Michael; Vollmer, Bruce

    2016-01-01

    The NASA Goddard Earth Sciences Data and Information Services Center (GES DISC) is the home of processing, archiving, and distribution services for NASA sounders: the present Aqua AIRS mission and the succeeding SNPP CrIS mission. The AIRS mission is entering its 15th year of global observations of the atmospheric state, including temperature and humidity profiles, outgoing longwave radiation, cloud properties, and trace gases. The GES DISC, in collaboration with the AIRS Project, released product from the version 6 algorithm in early 2013. Giovanni, a Web-based application developed by the GES DISC, provides a simple and intuitive way to visualize, analyze, and access vast amounts of Earth science remote sensing data without having to download the data. Most important variables from version 6 AIRS product are available in Giovanni. We are developing a climatology product using 14-year AIRS retrievals. The study can be a good start for the long term climatology from NASA sounders: the AIRS and the succeeding CrIS. This presentation will show the impacts to the climatology product from different aggregation methods. The climatology can serve climate science and application communities in data visualization and analysis, which will be demonstrated using a variety of functions in version 4 Giovanni. The highlights of these functions include user-defined monthly and seasonal climatology, inter annual seasonal time series, anomaly analysis.

  2. Migration of polycyclic aromatic hydrocarbons (PAHs) in urban treatment sludge to the air during PAH removal applications.

    Karaca, Gizem; Cindoruk, S Siddik; Tasdemir, Yücel

    2014-05-01

    In the present study, the amounts of polycylic aromatic hydrocarbons (PAHs) penetrating into air during PAH removal applications from the urban treatment sludge were investigated. The effects of the temperature, photocatalyst type, and dose on the PAH removal efficiencies and PAH evaporation were explained. The sludge samples were taken from an urban wastewater treatment plant located in the city of Bursa, with 585,000 equivalent population. The ultraviolet C (UV-C) light of 254 nm wavelength was used within the UV applications performed on a specially designed setup. Internal air of the setup was vacuumed through polyurethane foam (PUF) columns in order to collect the evaporated PAHs from the sludge during the PAH removal applications. All experiments were performed with three repetitions. The PAH concentrations were measured by gas chromatography-mass spectrometry (GC-MS). It was observed that the amounts of PAHs penetrating into the air were increased with increase of temperature, and more than 80% of PAHs migrated to the air consisted of 3-ring compounds during the UV and UV-diethylamine (DEA) experiments at 38 and 53 degrees C. It was determined that 40% decrease was ensured in sigma12 (total of 12) PAH amounts with UV application and 13% of PAHs in sludge penetrated into the air. In the UV-TiO2 applications, a maximum 80% of sigma12 PAH removal was obtained by adding 0.5% TiO2 of dry weight of sludge. The quantity of PAH penetrating into air did not exceed 15%. UV-TiO2 applications ensured high levels of PAH removal in the sludge and also reduced the quantity of PAH penetrating into the air. Within the scope of the samples added with DEA, there was no increase in PAH removal efficiencies and the penetration of PAHs into air was not decreased. In light of these data, it was concluded that UV-TiO2 application is the most suitable PAH removal alternative that restricts the convection of PAH pollution.

  3. When Cold Air Sleeps / Sean Lally

    Lally, Sean

    2009-01-01

    Klimaatiliste iseärasuste arvestamisest ja ärakasutamisest uute hoonete projekteerimisel. Näitena toodud firma Morris Architects Eesti Kunstiakadeemia uue hoone ja Võru Tamula järveäärse ala planeeringu konkursitööd

  4. Air Source Cold Climate Heat Pump

    2013-08-01

    nature of the system additional components were utilized as well. For instance, a capillary tube was used on all of the pressure switches and...Projects 97 August 2013 Building Automation Products, Inc. 750 North Royal Avenue, Gays Mills, WI 54631 USA Tel: +1-608-735·4800 ·Fax: +1-608-735-4804...Products, Inc 750 North Royal Ave. Gays Mills, WI 54631 USA ESTCP Final Report: 201136 Energy and Water Projects 98 August 2013 CE Declaration

  5. Characteristics of organic soil in black spruce forests: Implications for the application of land surface and ecosystem models in cold regions

    Yi, S.; Manies, K.; Harden, J.; McGuire, A.D.

    2009-01-01

    Soil organic layers (OL) play an important role in landatmosphere exchanges of water, energy and carbon in cold environments. The proper implementation of OL in land surface and ecosystem models is important for predicting dynamic responses to climate warming. Based on the analysis of OL samples of black spruce (Picea mariana), we recommend that implementation of OL for cold regions modeling: (1) use three general organic horizon types (live, fibrous, and amorphous) to represent vertical soil heterogeneity; (2) implement dynamics of OL over the course of disturbance, as there are significant differences of OL thickness between young and mature stands; and (3) use two broad drainage classes to characterize spatial heterogeneity, as there are significant differences in OL thickness between dry and wet sites. Implementation of these suggestions into models has the potential to substantially improve how OL dynamics influence variability in surface temperature and soil moisture in cold regions. Copyright 2009 by the American Geophys.ical Union.

  6. Cold fusion, Alchemist's dream

    Clayton, E.D.

    1989-09-01

    In this report the following topics relating to cold fusion are discussed: muon catalysed cold fusion; piezonuclear fusion; sundry explanations pertaining to cold fusion; cosmic ray muon catalysed cold fusion; vibrational mechanisms in excited states of D 2 molecules; barrier penetration probabilities within the hydrogenated metal lattice/piezonuclear fusion; branching ratios of D 2 fusion at low energies; fusion of deuterons into 4 He; secondary D+T fusion within the hydrogenated metal lattice; 3 He to 4 He ratio within the metal lattice; shock induced fusion; and anomalously high isotopic ratios of 3 He/ 4 He

  7. Rethinking Meta-Analysis: Applications for Air Pollution Data and Beyond

    Goodman, Julie E; Petito Boyce, Catherine; Sax, Sonja N; Beyer, Leslie A; Prueitt, Robyn L

    2015-01-01

    Meta-analyses offer a rigorous and transparent systematic framework for synthesizing data that can be used for a wide range of research areas, study designs, and data types. Both the outcome of meta-analyses and the meta-analysis process itself can yield useful insights for answering scientific questions and making policy decisions. Development of the National Ambient Air Quality Standards illustrates many potential applications of meta-analysis. These applications demonstrate the strengths and limitations of meta-analysis, issues that arise in various data realms, how meta-analysis design choices can influence interpretation of results, and how meta-analysis can be used to address bias and heterogeneity. Reviewing available data from a meta-analysis perspective can provide a useful framework and impetus for identifying and refining strategies for future research. Moreover, increased pervasiveness of a meta-analysis mindset—focusing on how the pieces of the research puzzle fit together—would benefit scientific research and data syntheses regardless of whether or not a quantitative meta-analysis is undertaken. While an individual meta-analysis can only synthesize studies addressing the same research question, the results of separate meta-analyses can be combined to address a question encompassing multiple data types. This observation applies to any scientific or policy area where information from a variety of disciplines must be considered to address a broader research question. PMID:25969128

  8. Study and application of measures for prevention of spontaneous combustion of coal in goaf induced by air leakage

    Liu, Y.; Tang, H.; Zou, S.; Shi, S. [Xiangtan Mining Institute (China)

    1996-12-01

    To prevent spontaneous ignition of coal due to air leakage in the goaf, air stoppings were built periodically in a U-shaped air leakage area based on computer simulation and site experience. The measure had reduced remarkably the quantity and extent of air leakage in the mined-out area and expanded the extent of non-spontaneous combustion area, thus prevented effectively the risk of spontaneous ignition and gas explosion. Application of this method in Mugang Mine of Liuzhi Bureau for more than two years had reduced the economic loss by over 3 million Yuan RMB. This method is characterized by simple operation, low cost, etc. It is suitable for mines in under developed area and mines with complicated conditions which are prone to spontaneous ignition. 5 refs., 3 figs., 1 tab.

  9. Note: implementation of a cold spot setup for controlled variation of vapor pressures and its application to an InBr containing discharge lamp.

    Briefi, S

    2013-02-01

    In order to allow for a systematic investigation of the plasma properties of discharges containing indium halides, which are proposed as an efficient alternative for mercury based low pressure discharge lamps, a controlled variation of the indium halide density is mandatory. This can be achieved by applying a newly designed setup in which a well-defined cold spot location is implemented and the cold spot temperature can be adjusted between 50 and 350 °C without influencing the gas temperature. The performance of the setup has been proved by comparing the calculated evaporated InBr density (using the vapor pressure curve) with the one measured via white light absorption spectroscopy.

  10. The application of cold-plasma coagulation on the visceral pleura results in a predictable depth of necrosis without fistula generation

    Hoffmann, Martin; Ulrich, Anita; Schloericke, Erik; Limmer, Stefan; Habermann, Jens Karsten; Wolken, Heike; Bruch, Hans-Peter; Kujath, Peter

    2011-01-01

    A technique for the safe transfer of electric energy to the pulmonary surface for the potential evaporation of malignant tumours is non-existent to date. By conducting the current study, we wanted to generate data on the potential beneficiary effects and complications of using cold-plasma coagulation on the pulmonary surface. Cold-plasma coagulation was applied to the pulmonary surface in eight female mini-pigs via a thoracoscopic access. After 12 days, we performed a re-thoracoscopy on the c...

  11. 78 FR 9038 - Office of the Secretary of the Air Force Acceptance of Group Application Under Public Law 95-202...

    2013-02-07

    ... DEPARTMENT OF DEFENSE Department of the Air Force Office of the Secretary of the Air Force Acceptance of Group Application Under Public Law 95-202 and Department of Defense Directive (DODD) 1000.20: U.S. and Foreign Employees of Air America, Inc. Under the provisions of Section 401, Public Law 95-202...

  12. Cold Antimatter Plasmas, and Aspirations for Cold Antihydrogen

    2002-06-24

    UNCLASSIFIED Defense Technical Information Center Compilation Part Notice ADP012494 TITLE: Cold Antimatter Plasmas, and Aspirations for Cold...part numbers comprise the compilation report: ADP012489 thru ADP012577 UNCLASSIFIED Cold Antimatter Plasmas, and Aspirations for Cold Antihydrogen G...and positrons. The antiprotons come initially from the new Antiproton Decel- erator facility at CERN. Good control of such cold antimatter plasmas is

  13. Air Division Mapping Application NAAQS Designations Map Service, Region 9, 2015, US EPA Region 9

    U.S. Environmental Protection Agency — Designated Areas - as of October 1, 2015. A designation is the term EPA uses to describe the air quality in a given area for any of six common air pollutants known...

  14. Application of a laser Doppler vibrometer for air-water to subsurface signature detection

    Land, Phillip; Roeder, James; Robinson, Dennis; Majumdar, Arun

    2015-05-01

    There is much interest in detecting a target and optical communications from an airborne platform to a platform submerged under water. Accurate detection and communications between underwater and aerial platforms would increase the capabilities of surface, subsurface, and air, manned and unmanned vehicles engaged in oversea and undersea activities. The technique introduced in this paper involves a Laser Doppler Vibrometer (LDV) for acousto-optic sensing for detecting acoustic information propagated towards the water surface from a submerged platform inside a 12 gallon water tank. The LDV probes and penetrates the water surface from an aerial platform to detect air-water surface interface vibrations caused by an amplifier to a speaker generating a signal generated from underneath the water surface (varied water depth from 1" to 8"), ranging between 50Hz to 5kHz. As a comparison tool, a hydrophone was used simultaneously inside the water tank for recording the acoustic signature of the signal generated between 50Hz to 5kHz. For a signal generated by a submerged platform, the LDV can detect the signal. The LDV detects the signal via surface perturbations caused by the impinging acoustic pressure field; proving a technique of transmitting/sending information/messages from a submerged platform acoustically to the surface of the water and optically receiving the information/message using the LDV, via the Doppler Effect, allowing the LDV to become a high sensitivity optical-acoustic device. The technique developed has much potential usage in commercial oceanography applications. The present work is focused on the reception of acoustic information from an object located underwater.

  15. The development of aluminum-air batteries for application in electric vehicles

    Rudd, E. J.; Lott, S.

    1990-12-01

    The recently concluded program, jointly funded by ELTECH Research Corporation and the Department of Energy, focused upon the development of an aluminum-air battery system for electric vehicle applications. The operation of the aluminum-air battery involves the dissolution of aluminum to produce a current and aluminate. Initially the objectives were to evaluate and optimize the battery design that was developed prior to this program (designated as the B300 cell) and to design and evaluate the components of the auxiliary system. During the program, three additional tasks were undertaken, addressing needs identified by ELTECH and by Sandia National Laboratories. First, the capability to produce aluminum alloys as relatively large ingots (100 to 150 lbs), with the required electrochemical performance, was considered essential to the development of the battery. The second additional task was the adoption of an advanced cell (designated as the AT400 cell), designed by ELTECH in a different program. Finally, it was recognized that a system model would allow evaluation of the interactions of the several unit operations involved in the battery. Therefore, the development of a mathematical model, based upon material and energy balances for the battery, was undertaken. At a systems level, sufficient information was obtained in the completion of this program to support the design, fabrication and operation of a batch or solids-free battery system. For the first time, the components of the auxiliary system, i.e., a heat exchanger, carbon dioxide scrubber and hydrogen disposal technology, have been defined for a vehicle battery. Progress on each component or system is summarized in the following sections.

  16. Intake fractions of industrial air pollutants in China. Estimation and application

    Wang, Shuxiao; Hao, Jiming; Li, Ji; Lu, Yongqi; Ho, Mun S.

    2006-01-01

    Intake fractions, an emissions-intake relationship for primary pollutants, are defined and are estimated in order to make simple estimates of health damages from air pollution. The sulfur dioxide (SO 2 ) and total suspended particles (TSP) intake fractions for five cities of China are estimated for the four main polluting industries-electric power generation, mineral (mostly cement) products industry, chemical process industry and metallurgical industry (mainly iron and steel smelting). The Industrial Source Complex Long Term (ISTLT3) model is used to simulate the spatial distribution of incremental ambient concentrations due to emissions from a large sample of site-specific sources. Detailed population distribution information is used for each city. The average intake fractions within 50 km of these sources are 4.4x10 -6 for TSP, and 4.2x10 -6 for SO 2 , with standard deviations of 8.15x10 -6 and 9.16x10 -6 , respectively. They vary over a wide range, from 10 -7 to 10 -5 . Although the electric power generation has been the focus of much of the air pollution research in China, our results show that it has the lowest average intake fraction for a local range among the four industries, which highlights the importance of pollutant emissions from other industrial sources. Sensitivity analyses show how the intake fractions are affected by the source and pollutant characteristics, the most important parameter being the size of the domain. However, the intake fraction estimates are robust enough to be useful for evaluating the local impacts on human health of primary SO 2 and TSP emissions. An application of intake fractions is given to demonstrate how this approach provides a rapid population risk estimate if the dose-response function is linear without threshold, and hence can help in prioritizing pollution control efforts. (author)

  17. Microlith-Based Catalytic Reactor for Air Quality and Trace Contaminant Control Applications

    Vilekar, Saurabh; Hawley, Kyle; Junaedi, Christian; Crowder, Bruce; Prada, Julian; Mastanduno, Richard; Perry, Jay L.; Kayatin, Matthew J.

    2015-01-01

    Traditionally, gaseous compounds such as methane, carbon monoxide, and trace contaminants have posed challenges for maintaining clean air in enclosed spaces such as crewed spacecraft cabins as they are hazardous to humans and are often difficult to remove by conventional adsorption technology. Catalytic oxidizers have provided a reliable and robust means of disposing of even trace levels of these compounds by converting them into carbon dioxide and water. Precision Combustion, Inc. (PCI) and NASA - Marshall (MSFC) have been developing, characterizing, and optimizing high temperature catalytic oxidizers (HTCO) based on PCI's patented Microlith® technology to meet the requirements of future extended human spaceflight explorations. Current efforts have focused on integrating the HTCO unit with a compact, simple recuperative heat exchanger to reduce the overall system size and weight while also reducing its energy requirements. Previous efforts relied on external heat exchangers to recover the waste heat and recycle it to the oxidizer to minimize the system's power requirements; however, these units contribute weight and volume burdens to the overall system. They also result in excess heat loss due to the separation of the HTCO and the heat recuperator, resulting in lower overall efficiency. Improvements in the recuperative efficiency and close coupling of HTCO and heat recuperator lead to reductions in system energy requirements and startup time. Results from testing HTCO units integrated with heat recuperators at a variety of scales for cabin air quality control and heat melt compactor applications are reported and their benefits over previous iterations of the HTCO and heat recuperator assembly are quantified in this paper.

  18. Air pollution biomonitoring in Argentina, application of neutron activation analysis to the study of biomonitors

    Pignata, M.L.; Pla, R.R.

    1999-01-01

    The assessment of baseline levels of atmospheric pollutants and the identification of polluted areas is a complex problem, as pollutant contents at a certain geographical location is usually a combination of contributions from various diverse sources, including long-range transport. Elemental chemical characterization of atmospheric pollutants is thus of great importance and Neutron Activation Analysis has proved to be a powerful technique for multielemental determination of trace elements in biomonitors and aerosols. The general objective of this project is to study the use of biomonitors, specially lichens, for evaluating pollutant levels over a wide geographic area of Argentina and for establishing baseline values and assessing time trends. Two lichen species (Usnea sp. and Ramalina ecklonii (Spreng.) Mey. and Flot) have been identified as suitable monitors of air pollution, with potential regional application at the central area of the country (province of Cordoba) and pilot studies have been initiated to test the practicability of sampling and sample collection. An area of approximately 40,000 km 2 will be covered by a sampling network, using in situ growing lichens. The distribution maps for the two selected species are already drawn and sampling of local soils will also be conducted. Current efforts at the Neutron Activation Analysis laboratory are put on assessing, for the selected lichen species, the influence of sample preparation methods on trace element concentrations. The use of other analytical techniques will allow the evaluation of the bioindicator chemical response and its relationship to different atmospheric quality levels. Source identification and apportionment will be done by statistical fingerprinting of the elemental concentrations, as sources of pollution are characterized by being composed of different mixtures of elements in different proportions. In this way and as a long-term objective, regional maps will be drawn showing the

  19. Application of a new Terrestrial Telecommunications System in the European Air Traffic

    Draško Marin

    2012-10-01

    Full Text Available Aeronautical Public Correspondence (APC is a telecommtmicationsse!Vice, which enables passengers onboard aircraftto make telecommunication calls to people on the ground.This article describes the terrestrial communications seiVicewhich is based on cellular network for the European CEPTmember countries (CEPT- European Conference of Postaland Telecommunications Administrations named TerrestrialFlight Telecommunications System (TFTS.This system is a Pan-European System, which means theusage of hannonised frequencies in Europe with hannonisedstandards for the TFTS equipment, which have been issued bythe European Telecommunications Standard Institute (ETSI.Frequencies allocated for TFTS have been designated bythe World Administrative Radio Conference, WARC-92 withfrequency bandwidth of 2x5 MHz:1670- 1675 MHz, for ground to air1800- 1805 MHz, for air to ground.TFTS planning is perfonned by the application of frequencyblocks (42 blocks with 164 channels in total. Bandwidthof each radio channel, which contains 4 speech channels,is equal to 30.3 kHz.Due to the very high flight of the aircraft (about 13,000 m,it needs a long distance between the centres of cells (radio stationon the ground to avoid the eo-channel or adjacent channelinteJference.The article presents the planning process with typical cellradius of240km or 350km. In the viewofthatfact, the need ispointed out for finding a compromise solution with regard toemitting power and the influence of interference.Final(v, it is noted that TFTS ground radio stations inCroatia, which are located in Zagreb and Split, may cover theterritory of some neighbouring countries other than Croatia,which is important from the commercial point of view.

  20. 77 FR 21145 - Notice of Applications for Certificates of Public Convenience and Necessity and Foreign Air...

    2012-04-09

    ... Public Convenience and Necessity and Foreign Air Carrier Permits Filed Under Subpart B (Formerly Subpart... Convenience and Necessity and Foreign Air Carrier Permits were filed under Subpart B (formerly Subpart Q) of... convenience and necessity authorizing People Express to engage in interstate scheduled air transportation of...

  1. 76 FR 69320 - Notice of Applications for Certificates of Public Convenience and Necessity and Foreign Air...

    2011-11-08

    ... Public Convenience and Necessity and Foreign Air Carrier Permits Filed Under Subpart B (Formerly Subpart... Convenience and Necessity and Foreign Air Carrier Permits were filed under Subpart B (formerly Subpart Q) of... certificate of public convenience and necessity for Route 568 to engage in scheduled foreign air...

  2. 76 FR 54524 - Notice of Applications for Certificates of Public Convenience and Necessity and Foreign Air...

    2011-09-01

    ... Public Convenience and Necessity and Foreign Air Carrier Permits Filed Under Subpart B (Formerly Subpart... Convenience and Necessity and Foreign Air Carrier Permits were filed under subpart B (formerly subpart Q) of... convenience and necessity authorizing Universal to engage in foreign charter air transportation of persons...

  3. 78 FR 45011 - Notice of Applications for Certificates of Public Convenience and Necessity and Foreign Air...

    2013-07-25

    ... Public Convenience and Necessity and Foreign Air Carrier Permits Filed Under Subpart B (Formerly Subpart... Convenience and Necessity and Foreign Air Carrier Permits were filed under Subpart B (formerly Subpart Q) of... reissuance of Pinnacle's certificates of public convenience and necessity in the name of ``ENDEAVOR AIR, INC...

  4. 77 FR 54944 - Notice of Applications for Certificates of Public Convenience and Necessity and Foreign Air...

    2012-09-06

    ... Public Convenience and Necessity and Foreign Air Carrier Permits Filed Under Subpart B (Formerly Subpart... Convenience and Necessity and Foreign Air Carrier Permits were filed under Subpart B (formerly Subpart Q) of... public convenience and necessity authorizing it to conduct foreign charter air transportation of persons...

  5. Application of principal component analysis to time series of daily air pollution and mortality

    Quant C; Fischer P; Buringh E; Ameling C; Houthuijs D; Cassee F; MGO

    2004-01-01

    We investigated whether cause-specific daily mortality can be attributed to specific sources of air pollution. To construct indicators of source-specific air pollution, we applied a principal component analysis (PCA) on routinely collected air pollution data in the Netherlands during the period

  6. 75 FR 51870 - Wheego Electric Cars, Inc.; Receipt of Application for Temporary Exemption From Advanced Air Bag...

    2010-08-23

    ...-0118] Wheego Electric Cars, Inc.; Receipt of Application for Temporary Exemption From Advanced Air Bag... with the procedures in 49 CFR part 555, Wheego Electric Cars, Inc., has petitioned the agency for a... requirements submitted by a manufacturer of a small electric car. II. Overview of Wheego's Petition for...

  7. 76 FR 7898 - Wheego Electric Cars, Inc.; Grant of Application for Temporary Exemption From Advanced Air Bag...

    2011-02-11

    ...-0118] Wheego Electric Cars, Inc.; Grant of Application for Temporary Exemption From Advanced Air Bag... grants the petition of Wheego Electric Cars, Inc. (Wheego) for the temporary exemption of its Whip LiFe... manufacturer of a plug-in electric car. The stated basis of the petition was that requiring compliance would...

  8. 75 FR 8178 - Application of Rugby Aviation LLC D/B/A Northwest Sky Ferry for Commuter Air Carrier Authority

    2010-02-23

    ... DEPARTMENT OF TRANSPORTATION Office of the Secretary Application of Rugby Aviation LLC D/B/A Northwest Sky Ferry for Commuter Air Carrier Authority AGENCY: Department of Transportation. ACTION: Notice... Transportation is directing all interested persons to show cause why it should not issue an order finding Rugby...

  9. 40 CFR 424.40 - Applicability; description of the covered calcium carbide furnaces with wet air pollution control...

    2010-07-01

    ... 40 Protection of Environment 28 2010-07-01 2010-07-01 true Applicability; description of the covered calcium carbide furnaces with wet air pollution control devices subcategory. 424.40 Section 424.40 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS FERROALLOY MANUFACTURING POINT SOURCE...

  10. 40 CFR 424.10 - Applicability; description of the open electric furnaces with wet air pollution control devices...

    2010-07-01

    ... 40 Protection of Environment 28 2010-07-01 2010-07-01 true Applicability; description of the open electric furnaces with wet air pollution control devices subcategory. 424.10 Section 424.10 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS FERROALLOY MANUFACTURING POINT SOURCE CATEGORY Open...

  11. Web-based Air Quality Screening Tool for Near-port Assessments: Example of Application in Porto, Portugal

    The HARMO conference presents an opportunity to extend and further develop ORD’s collaboration with our European colleagues. This paper describes the C-PORT application in Porto, Portugal as a part of the EU project AIRSHIP designed to evaluate the air quality impacts of m...

  12. Measurement of the refractive index of air in a low-pressure regime and the applicability of traditional empirical formulae

    Schödel, René; Walkov, Alexander; Voigt, Michael; Bartl, Guido

    2018-06-01

    The refractive index of air is a major limiting factor in length measurements by interferometry, which are mostly performed under atmospheric conditions. Therefore, especially in the last century, measurement and description of the air refractive index was a key point in order to achieve accuracy in the realisation of the length by interferometry. Nevertheless, interferometric length measurements performed in vacuum are much more accurate since the wavelength of the light is not affected by the air refractive index. However, compared with thermal conditions in air, in high vacuum heat conduction is missing. In such a situation, dependent on the radiative thermal equilibrium, a temperature distribution can be very inhomogeneous. Using a so-called contact gas instead of high vacuum is a very effective way to enable heat conduction on nearly the same level as under atmospheric pressure conditions whereby keeping the effect of the air refractive index on a small level. As physics predicts, and as we have demonstrated previously, helium seems like the optimal contact gas because of its large heat conduction and its refractive index that can be calculated from precisely known parameters. On the other hand, helium gas situated in a vacuum chamber could easily be contaminated, e.g. by air leakage from outside. Above the boiling point of oxygen (‑183 °C) it is therefore beneficial to use dry air as a contact gas. In such an approach, the air refractive index could be calculated based on measured quantities for pressure and temperature. However, existing formulas for the air refractive index are not valid in the low-pressure regime. Although it seems reasonable that the refractivity (n  ‑  1) of dry air simply downscales with the pressure, to our knowledge there is no experimental evidence for the applicability of any empirical formula. This evidence is given in the present paper which reports on highly accurate measurements of the air refractive index for the

  13. The Application of Hermeneutical Analysis to Research on the Cold War in Soviet Animation Media Texts from the Second Half of the 1940s

    Fedorov, A. V.

    2015-01-01

    The Cold War era, which spawned a mutual ideological confrontation between communist and capitalist countries, left its mark on all categories of media texts, including cartoons and animations. Cartoons were used by the authorities as tools for delivering the necessary confrontational ideological content in an attractive folkloric, fairy-tale…

  14. Working in the Cold

    2016-02-08

    During the winter, many workers are outdoors, working in cold, wet, icy, or snowy conditions. Learn how to identify symptoms that tell you there may be a problem and protect yourself from cold stress.  Created: 2/8/2016 by National Institute for Occupational Safety and Health (NIOSH).   Date Released: 2/8/2016.

  15. Cold-Weather Sports

    ... Videos for Educators Search English Español Cold-Weather Sports KidsHealth / For Teens / Cold-Weather Sports What's in this article? What to Do? Classes ... weather. What better time to be outdoors? Winter sports can help you burn calories, increase your cardiovascular ...

  16. Cold fusion research

    1989-11-01

    I am pleased to forward to you the Final Report of the Cold Fusion Panel. This report reviews the current status of cold fusion and includes major chapters on Calorimetry and Excess Heat, Fusion Products and Materials Characterization. In addition, the report makes a number of conclusions and recommendations, as requested by the Secretary of Energy

  17. COLD-WORKED HARDWARE

    N. M. Strizhak

    2007-01-01

    Full Text Available The different types of cold-worked accessory are examined in the article. The necessity of development of such type of accessory in the Republic of Belarus due to requirements of market is shown. High emphasis is placed on the methods of increase of plasticity of cold-worked accessory from usual mill of RUP and CIS countries.

  18. Liquid metal cold trap

    Hundal, R.

    1976-01-01

    A cold trap assembly for removing impurities from a liquid metal is described. A hole between the incoming impure liquid metal and purified outgoing liquid metal acts as a continuous bleed means and thus prevents the accumulation of cover gases within the cold trap assembly

  19. Simulation of a hot air engine for a generation of electricity using biogas for Tanzania rural application

    Mkiramweni, L.L.N.; Msaki, P.; Mshoro, I.B.

    2007-01-01

    At the moment, about 80% of the rural population in Tanzania lacks grid electricity. As a result, up to 90% of energy requirements in rural areas are met by firewood and hence causing deforestation. In the present paper, the authors are advocating the application of biogas to generate electricity in rural areas to minimise deforestation. Preliminary study conducted has shown that the power required in rural areas is about 10kW for household and small economic activities. As such, the authors have investigated the possibility of applying a hot air engine using biogas as a source of energy to generate electricity. The study involved simulation of hot air engine using a Stirling Numerical Analysis Program (SNAP) with use modifiable code. In the exercise, the performance of the simulated engine was assessed with helium, hydrogen and air as working media. Reheat loss and pressure losses were also assessed for varies range of engine power and efficiency. It has been observed that with helium and hydrogen as working gas, the power output could easily reach 10kW, which is sufficient for rural household application. However, with air the engine could realise only 4kW under similar conditions. It has further been observed that air has bigger and more viscous molecular with lower thermal conductivity and heat capacity, which results in higher losses. This implies that a relatively bigger engine need be employed for running with air. However, high initial cost will be offset by the reduction in operating cost, since air is freely available. For proper operation of the engine heater temperature should be maintained above 630(deg)C, which is realizable with biogas having a flame temperature of about 870(deg)C. (author)

  20. Amperometric Gas Sensors as a Low Cost Emerging Technology Platform for Air Quality Monitoring Applications: A Review.

    Baron, Ronan; Saffell, John

    2017-11-22

    This review examines the use of amperometric electrochemical gas sensors for monitoring inorganic gases that affect urban air quality. First, we consider amperometric gas sensor technology including its development toward specifically designed air quality sensors. We then review recent academic and research organizations' studies where this technology has been trialed for air quality monitoring applications: early studies showed the potential of electrochemical gas sensors when colocated with reference Air Quality Monitoring (AQM) stations. Spatially dense networks with fast temporal resolution provide information not available from sparse AQMs with longer recording intervals. We review how this technology is being offered as commercial urban air quality networks and consider the remaining challenges. Sensors must be sensitive, selective, and stable; air quality monitors/nodes must be electronically and mechanically well designed. Data correction is required and models with differing levels of sophistication are being designed. Data analysis and validation is possibly the biggest remaining hurdle needed to deliver reliable concentration readings. Finally, this review also considers the roles of companies, urban infrastructure requirements, and public research in the development of this technology.

  1. Survey of Indoor Air Quality in the University of Alaska

    Kotol, Martin; Craven, Colin; Rode, Carsten

    2014-01-01

    problem which is poor indoor air quality (IAQ). During summer 2012 four student homes were built in Fairbanks, Alaska as a part of Sustainable Village project. The aim of this project is to promote sustainable ways of living in the Arctic and to study new technologies and their applicability in the cold......In cold climates living inside the heated space requires considerable amounts of heat. With the intention to decrease the heating demand, people are insulating their homes and make them more air tight. With the natural infiltration being brought close to zero there has been an increase of a new...... north. This paper presents the results of an IAQ survey performed in the homes during two weeks in December 2012. During this survey the air temperature, relative humidity (RH) and CO2 concentration were measured in all occupied bedrooms along with monitoring of the ventilation units. The results have...

  2. National emission standards for hazardous air pollutants application for approval to stabilize the 105N Basin

    1994-01-01

    The 105N Basin (basin) Stabilization will place the basin in a radiologically and environmentally safe condition so that it can be decommissioned at a later date. The basin stabilization objectives are to inspect for Special Nuclear Material (SNM) (i.e., fuel assemblies and fuel pieces), remove the water from the basin and associated pits, and stabilize the basin surface. The stabilization will involve removal of basin hardware, removal of basin sediments, draining of basin water, and cleaning and stabilizing basin surfaces-to prevent resuspension of radioactive emissions to the air. These activities will be conducted in accordance with all applicable regulations. The basin is in the 105N Building, which is located in the 100N Area. The 100N Area is located in the Northern portion of the Hanford Site approximately 35 miles northwest of the city of Richland, Washington. The basin is a reinforced unlined concrete structure 150 feet long, 50 feet wide, and 24 feet deep. The basin is segregated into seven areas sharing a common pool of water; the Discharge/Viewing (''D'') Pit, the fuel segregation pit (including a water tunnel that connects the ''D'' pit and segregation pit), two storage basins designated as North Basin and South Basin, two cask load-out pits, and a fuel examination area. The North Basin floor is entirely covered and the South Basin is partly covered by a modular array of cubicles formed by boron concrete posts and boron concrete panels

  3. Application of porous medium for efficiency improvement of a concentrated solar air heating system

    Prasartkaew, Boonrit

    2018-01-01

    The objective of this study is to evaluate the thermal efficiency of a concentrated solar collector for a high temperature air heating system. The proposed system consists of a 25-m2 focused multi-flat-mirror solar heliostat equipped with a porous medium solar collector/receiver which was installed on the top of a 3-m tower, called ‘tower receiver’. To know how the system efficiency cloud be improved by using porous medium, the proposed system with and without porous medium were tested and the comparative study was performed. The experimental results reveal that, for the proposed system, application of porous medium is promising, the efficiency can be increased about 2 times compared to the conventional one. In addition, due to the porous medium used in this study was the waste material with very low cost. It can be summarized that the substantial efficiency improvement with very low investment cost of the proposed system seem to be a vital measures for addressing the energy issues.

  4. Exergy Analysis of Air-Gap Membrane Distillation Systems for Water Purification Applications

    Daniel Woldemariam

    2017-03-01

    Full Text Available Exergy analyses are essential tools for the performance evaluation of water desalination and other separation systems, including those featuring membrane distillation (MD. One of the challenges in the commercialization of MD technologies is its substantial heat demand, especially for large scale applications. Identifying such heat flows in the system plays a crucial role in pinpointing the heat loss and thermal integration potential by the help of exergy analysis. This study presents an exergetic evaluation of air-gap membrane distillation (AGMD systems at a laboratory and pilot scale. A series of experiments were conducted to obtain thermodynamic data for the water streams included in the calculations. Exergy efficiency and destruction for two different types of flat-plate AGMD were analyzed for a range of feed and coolant temperatures. The bench scale AGMD system incorporating condensation plate with more favorable heat conductivity contributed to improved performance parameters including permeate flux, specific heat demand, and exergy efficiency. For both types of AGMD systems, the contributions of the major components involved in exergy destruction were identified. The result suggested that the MD modules caused the highest fraction of destructions followed by re-concentrating tanks.

  5. Application of Fast Neutron Activity for Analysing Element Content on the Air Particulate

    Elin Nuraini; Ngasifudin; Sunardi; Elisabeth

    2003-01-01

    The research on application of fast neutron activation analysis for analysing element content on the air particulate has been done. The research about analysis of the particulate matters contained in non industrial traffic territory of Surakarta and full industrial traffic territory of Karanganyar, had been done using Fast Neutron Activation Analysis Method. Fast Neutron Activation Analysis method is one of the element analysis method which it's basic principle causes radioactivity appearance from the samples after being irradiated by neutron. The qualitative analysis method is based on the measuring of specific energy which was radiated by radioactive's nucleus and quantitative analysis method is based on the measuring of the intensity of each peak gamma energy. The qualitative analysis results showed, some element were identified i.e : 51 V ; 200 Pb, 27 Al and 52 Cr. The result showed that Pb level is 2.21 ± 0.09x10 -1 mg/m 3 in non industrial traffic territory of Surakarta and 2.78 ± 0.11x10 -1 mg/m 3 full industrial traffic territory of Karanganyar, this value greater than threshold value according 6.0x10 -2 mg/m 3 . (author)

  6. Effect of air-drying time of single-application self-etch adhesives on dentin bond strength.

    Chiba, Yasushi; Yamaguchi, Kanako; Miyazaki, Masashi; Tsubota, Keishi; Takamizawa, Toshiki; Moore, B Keith

    2006-01-01

    This study examined the effect of air-drying time of adhesives on the dentin bond strength of several single-application self-etch adhesive systems. The adhesive/resin composite combinations used were: Adper Prompt L-Pop/Filtek Z250 (AP), Clearfil Tri-S Bond/Clearfil AP-X (CT), Fluoro Bond Shake One/Beautifil (FB), G-Bond/Gradia Direct (GB) and One-Up Bond F Plus/Palfique Estelite (OF). Bovine mandibular incisors were mounted in self-curing resin and wet ground with #600 SiC to expose labial dentin. Adhesives were applied according to each manufacturer's instructions followed by air-drying time for 0 (without air-drying), 5 and 10 seconds. After light irradiation of the adhesives, the resin composites were condensed into a mold (phi4x2 mm) and polymerized. Ten samples per test group were stored in 37 degrees C distilled water for 24 hours; they were then shear tested at a crosshead speed of 1.0 mm/minute. One-way ANOVA followed by Tukey's HSD tests (alpha = 0.05) were done. FE-SEM observations of the resin/dentin interface were also conducted. Dentin bond strength varied with the different air drying times and ranged from 5.8 +/- 2.4 to 13.9 +/- 2.8 MPa for AP, 4.9 +/- 1.5 to 17.1 +/- 2.3 MPa for CT, 7.9 +/- 2.8 to 13.8 +/- 2.4 MPa for FB, 3.7 +/- 1.4 to 13.4 +/- 1.2 MPa for GB and 4.6 +/- 2.1 to 13.7 +/- 2.6 MPa for OF. With longer air drying of adhesives, no significant changes in bond strengths were found for the systems used except for OF. Significantly lower bond strengths were obtained for the 10-second air-drying group for OF. From FE-SEM observations, gaps between the cured adhesive and resin composites were observed for the specimens without the air drying of adhesives except for OF. The data suggests that, with four of the single-application self-etch adhesive systems, air drying is essential to obtain adequate dentin bond strengths, but increased drying time does not significantly influence bond strength. For the other system studied, the bond strength

  7. Human whole body cold adaptation.

    Daanen, Hein A.M.; Van Marken Lichtenbelt, Wouter D.

    2016-01-01

    Reviews on whole body human cold adaptation generally do not distinguish between population studies and dedicated acclimation studies, leading to confusing results. Population studies show that indigenous black Africans have reduced shivering thermogenesis in the cold and poor cold induced

  8. [Impacts on repeated common cold for the adults with different constitutions treated by acupoint application in the dog days and the three nine-day periods after the winter solstice].

    Lou, Bi-Dan; Yang, Li-Bai; Zhang, Wei; Li, Jin-Xiang; Li, Xiao-Ping; Li, Wu; Yang, Shu-Quan; Huang, Xiang-Hong; Liu, Xing-Ping; Cao, Yue; Pan, Jiang

    2012-11-01

    To observe the impacts on repeated common cold for the adults with different constitutions treated by acupoint application in the dog days (the three periods of the hottest days) and the three nine-day periods after the winter solstice (the three periods of the coldest days). One hundred and fifty-two cases of repeated common cold were divided into four zones according to the body constitution. Each zone was sub-divided into a group of the dog days + the three nine-day periods of the coldest days (group A), and a simple group of the dog periods (group B). In both groups, Dazhui (GV 14), Feishu (BL 13), Tiantu (CV 22), Danzhong (CV 17), Zhongfu (LU 1) and Shenshu (BL 23) were selected. In group A, the acupoint application was given on the 1st or 2nd day of the first, second and third periods of the hottest days in 2010, as well as the 1st or 2nd day of the first, second and third periods of the coldest days in 2010 separately. In group B, the acupoint application was only given on the 1st or 2nd day of the first, second and third periods of the hottest days in 2010. The follow-up visit was conducted before the acupoint application in the three periods of the coldest days in 2010 and before the acupoint application in the three periods of the hottest days in 2011. Additionally, the frequency of disease attack and the symptom score in sickness were taken as the observation indices for the efficacy assessment in both groups. (1) In both groups, the attack frequency was reduced obviously in half a year after the three periods of the hottest days for the patients of qi deficiency constitution, yang deficiency constitution and qi stagnation constitution and the clinical symptom score were reduced apparently (all Pcoldest days for the patients of those four constitutions as compared with those before treatment (all Pcoldest days, the efficacy for reducing the attack frequency and the improvements in the clinical symptoms were better than those in group B (all P<0.01). The

  9. The cold neutron source in DR 3

    Jensen, K.; Leth, j.A.

    1980-09-01

    A description of the cold neutron source in DR 3 is given. The moderator of the cold neutron source is supercritical hydrogen at about 30degK and 15 bar abs. The necessary cooling capacity is supplied by two Philips Stirling B20 cryogenerators. The hydrogen is circulated between the cryogenerators and the in-pile moderator chamber by small fans. The safety of the facility is based on the use of triple containment preventing contact between hydrogen and air. The triple containment is achieved by enclosing the high vacuum system, surrounging the hydrogen system, in a helium blanket. The achieved spectrum of the thermal neutron flux and the gain factor are given as well as the experience from more than 5 years of operation. Finally some work on extension of the facility to operate two cold sources is reported. (author)

  10. PCM-air heat exchangers for free-cooling applications in buildings: Experimental results of two real-scale prototypes

    Lazaro, Ana; Dolado, Pablo; Marin, Jose M.; Zalba, Belen

    2009-01-01

    Latent heat storage using phase change materials (PCM) can be used for free-cooling. In this application low air temperature is used to solidify the PCM during the night and then during the next day, the inside air of a building can be cooled down by exchanging heat with PCM. Short times for charging and discharging the PCM are required. PCM have in general low thermal conductivity, therefore the heat exchanger design is very important to fulfil free-cooling requirements. This paper presents an experimental setup for testing PCM-air real-scale heat exchangers and the results for two real-scale prototypes. Results show that a heat exchanger using a PCM with lower thermal conductivity and lower total stored energy, but adequately designed, has higher cooling power and can be applied for free-cooling

  11. Cold forming of aluminium - State of the art

    Bay, Niels

    1997-01-01

    The ongoing development of cold forging technology has been manifested lately by the increasing application of components in cold forged aluminium alloys. Applying precipitation hardening alloys components with great strength/weight ratio can be produced with a strength comparable...... to that of unalloyed steel. After description of the different types of alloys and their individual properties and applications, the special requirements for tool design by cold forging in aluminium is discussed. Finally, a large number of industrial examples on cold forged aluminium components are presented. (C) 1997...

  12. 75 FR 57544 - Notice of Applications for Certificates of Public Convenience and Necessity and Foreign Air...

    2010-09-21

    ... Public Convenience and Necessity and Foreign Air Carrier Permits Filed under Subpart B (Formerly Subpart... Convenience and Necessity and Foreign Air Carrier Permits were filed under Subpart B (formerly Subpart Q) of... the transfer from ASTAR to AUSA of ASTAR's certificates of public convenience and necessity...

  13. 77 FR 54945 - Notice of Applications for Certificates of Public Convenience and Necessity and Foreign Air...

    2012-09-06

    ... Public Convenience and Necessity and Foreign Air Carrier Permits Filed Under Subpart B (Formerly Subpart... Convenience and Necessity and Foreign Air Carrier Permits were filed under Subpart B (formerly Subpart Q) of... disclaim jurisdiction over the transfer of its certificates of public convenience and necessity to...

  14. 76 FR 68256 - Notice of Applications for Certificates of Public Convenience and Necessity and Foreign Air...

    2011-11-03

    ... Public Convenience and Necessity and Foreign Air Carrier Permits Filed Under Subpart B (Formerly Subpart... Convenience and Necessity and Foreign Air Carrier Permits were filed under Subpart B (formerly Subpart Q) of... Corporation (``JetBlue'') requesting a certificate of public convenience and necessity and requests the...

  15. 76 FR 10085 - Notice of Applications for Certificates of Public Convenience and Necessity and Foreign Air...

    2011-02-23

    ... Public Convenience and Necessity and Foreign Air Carrier Permits Filed Under Subpart B (Formerly Subpart... Convenience and Necessity and Foreign Air Carrier Permits were filed under Subpart B (formerly Subpart Q) of... its certificate of public convenience and necessity in that name. Renee V. Wright, Program Manager...

  16. Exploring the applicability of future air quality predictions based on synoptic system forecasts

    Yuval; Broday, David M.; Alpert, Pinhas

    2012-01-01

    For a given emissions inventory, the general levels of air pollutants and the spatial distribution of their concentrations are determined by the physiochemical state of the atmosphere. Apart from the trivial seasonal and daily cycles, most of the variability is associated with the atmospheric synoptic scale. A simple methodology for assessing future levels of air pollutants' concentrations based on synoptic forecasts is presented. At short time scales the methodology is comparable and slightly better than persistence and seasonal forecasts at categorical classification of pollution levels. It's utility is shown for air quality studies at the long time scale of a changing climate scenario, where seasonality and persistence cannot be used. It is demonstrated that the air quality variability due to changes in the pollution emissions can be expected to be much larger than that associated with the effects of climatic changes. - Highlights: ► A method for short and long term air quality forecasts is introduced. ► The method is based on prediction of synoptic systems. ► The method beats simple benchmarks in short term forecasts. ► Assessment of future air pollution in a changing climate scenario is demonstrated. - Air quality in a changing climate scenario can be studied using air pollution predictions based on synoptic system forecasts.

  17. Application of evaporative cooling on the condenser of window-air-conditioner

    Hajidavalloo, Ebrahim

    2007-01-01

    Reduction of energy consumption is a major concern in the vapor compression refrigeration cycle especially in the area with very hot weather conditions (about 50 deg. C), where window-air-conditioners are usually used to cool homes. In this weather condition performance of air condenser window-air-conditioners decrease sharply and electrical power consumption increase considerably. These problems have activated the research programs in order to improve the performance of window-air-conditioners by enhancing heat transfer rate in the condenser. In this article, a new design with high commercialization potential for incorporating of evaporative cooling in the condenser of window-air-conditioner is introduced and experimentally investigated. A real air conditioner is used to test the innovation by putting two cooling pads in both sides of the air conditioner and injecting water on them in order to cool down the air before it passing over the condenser. The experimental results show that thermodynamic characteristics of new system are considerably improved and power consumption decreases by about 16% and the coefficient of performance increases by about 55%

  18. Application of evaporative cooling on the condenser of window-air-conditioner

    Hajidavalloo, Ebrahim [Shahid Chamran University, Department of Mechanical Engineering, Golestan St., Ahwaz, Khoozestan 61355 (Iran, Islamic Republic of)]. E-mail: hajidae_1999@yahoo.com

    2007-08-15

    Reduction of energy consumption is a major concern in the vapor compression refrigeration cycle especially in the area with very hot weather conditions (about 50 deg. C), where window-air-conditioners are usually used to cool homes. In this weather condition performance of air condenser window-air-conditioners decrease sharply and electrical power consumption increase considerably. These problems have activated the research programs in order to improve the performance of window-air-conditioners by enhancing heat transfer rate in the condenser. In this article, a new design with high commercialization potential for incorporating of evaporative cooling in the condenser of window-air-conditioner is introduced and experimentally investigated. A real air conditioner is used to test the innovation by putting two cooling pads in both sides of the air conditioner and injecting water on them in order to cool down the air before it passing over the condenser. The experimental results show that thermodynamic characteristics of new system are considerably improved and power consumption decreases by about 16% and the coefficient of performance increases by about 55%.

  19. Chilling Out With Colds

    ... and use the time to read, listen to music, or watch a movie. In other words, chill out and you might prevent a cold! Reviewed by: Patricia ... Policy Permissions Guidelines Privacy Policy & Terms of Use Notice ...

  20. Cold Vacuum Drying Facility

    Federal Laboratory Consortium — Located near the K-Basins (see K-Basins link) in Hanford's 100 Area is a facility called the Cold Vacuum Drying Facility (CVDF).Between 2000 and 2004, workers at the...

  1. Uncertainty characterization and quantification in air pollution models. Application to the CHIMERE model

    Debry, Edouard; Mallet, Vivien; Garaud, Damien; Malherbe, Laure; Bessagnet, Bertrand; Rouïl, Laurence

    2010-05-01

    Prev'Air is the French operational system for air pollution forecasting. It is developed and maintained by INERIS with financial support from the French Ministry for Environment. On a daily basis it delivers forecasts up to three days ahead for ozone, nitrogene dioxide and particles over France and Europe. Maps of concentration peaks and daily averages are freely available to the general public. More accurate data can be provided to customers and modelers. Prev'Air forecasts are based on the Chemical Transport Model CHIMERE. French authorities rely more and more on this platform to alert the general public in case of high pollution events and to assess the efficiency of regulation measures when such events occur. For example the road speed limit may be reduced in given areas when the ozone level exceeds one regulatory threshold. These operational applications require INERIS to assess the quality of its forecasts and to sensitize end users about the confidence level. Indeed concentrations always remain an approximation of the true concentrations because of the high uncertainty on input data, such as meteorological fields and emissions, because of incomplete or inaccurate representation of physical processes, and because of efficiencies in numerical integration [1]. We would like to present in this communication the uncertainty analysis of the CHIMERE model led in the framework of an INERIS research project aiming, on the one hand, to assess the uncertainty of several deterministic models and, on the other hand, to propose relevant indicators describing air quality forecast and their uncertainty. There exist several methods to assess the uncertainty of one model. Under given assumptions the model may be differentiated into an adjoint model which directly provides the concentrations sensitivity to given parameters. But so far Monte Carlo methods seem to be the most widely and oftenly used [2,3] as they are relatively easy to implement. In this framework one

  2. Hot air in Kyoto, cold air in The Hague

    Steiner, Urs; Svendsen, Gert Tinggaard

    2001-01-01

    Summary: Why did the climate negotiations in The Hague fail? Our contribution is to argue that the conflict between the European Union (EU) and the United States (US) stems mainly from disagreement on the cost issue. We argue that three main concerns promoted by the EU in The Hague. First, a 50...

  3. Hot air in Kyoto, cold air in The Hague

    Brandt, Urs Steiner; Svendsen, Gert Tinggaard

    2002-01-01

    Why did the climate negotiations in The Hague fail? Our contribution is to argue that the conflict between the European Union (EU) and the United States (US) stems mainly from disagreement on the cost issue. We argue that three main concerns promoted by the EU in The Hague. First, a 50% national...

  4. Measuring the value of air quality: application of the spatial hedonic model.

    Kim, Seung Gyu; Cho, Seong-Hoon; Lambert, Dayton M; Roberts, Roland K

    2010-03-01

    This study applies a hedonic model to assess the economic benefits of air quality improvement following the 1990 Clean Air Act Amendment at the county level in the lower 48 United States. An instrumental variable approach that combines geographically weighted regression and spatial autoregression methods (GWR-SEM) is adopted to simultaneously account for spatial heterogeneity and spatial autocorrelation. SEM mitigates spatial dependency while GWR addresses spatial heterogeneity by allowing response coefficients to vary across observations. Positive amenity values of improved air quality are found in four major clusters: (1) in East Kentucky and most of Georgia around the Southern Appalachian area; (2) in a few counties in Illinois; (3) on the border of Oklahoma and Kansas, on the border of Kansas and Nebraska, and in east Texas; and (4) in a few counties in Montana. Clusters of significant positive amenity values may exist because of a combination of intense air pollution and consumer awareness of diminishing air quality.

  5. Construction and application of an intelligent air quality monitoring system for healthcare environment.

    Yang, Chao-Tung; Liao, Chi-Jui; Liu, Jung-Chun; Den, Walter; Chou, Ying-Chyi; Tsai, Jaw-Ji

    2014-02-01

    Indoor air quality monitoring in healthcare environment has become a critical part of hospital management and policy. Manual air sampling and analysis are cost-inhibitive and do not provide real-time air quality data and response measures. In this month-long study over 14 sampling locations in a public hospital in Taiwan, we observed a positive correlation between CO(2) concentration and population, total bacteria, and particulate matter concentrations, thus monitoring CO(2) concentration as a general indicator for air quality could be a viable option. Consequently, an intelligent environmental monitoring system consisting of a CO(2)/temperature/humidity sensor, a digital plug, and a ZigBee Router and Coordinator was developed and tested. The system also included a backend server that received and analyzed data, as well as activating ventilation and air purifiers when CO(2) concentration exceeded a pre-set value. Alert messages can also be delivered to offsite users through mobile devices.

  6. Lithium-air batteries: survey on the current status and perspectives towards automotive applications from a battery industry standpoint

    Park, Myounggu; Sun, Heeyoung; Lee, Hyungbok; Lee, Junesoo [Battery R and D, SK Innovation, Wonchon-dong, Yuseong-gu, Daejeon (Korea, Republic of); Cho, Jaephil [Interdisciplinary School of Green Energy, Ulsan National Institute of Science and Technology (UNIST), Ulsan (Korea, Republic of)

    2012-07-15

    Li-air rechargeable batteries theoretically have advantages from both secondary batteries and fuel cells, which can be viewed as the best technological blends for automotive applications resolving the so called mileage anxiety problem due to the limited driving range of electrical vehicles based upon Li-ion batteries; this problem is rooted in the intrinsically small energy density of Li-ion batteries. This very scientific trait of Li-air batteries, which is apparently suited to the requirements of batteries for future electric vehicles, has induced quite a strong surge of research recently. This occurrence has motivated the authors to undertake a thorough review in an effort to understand the current status of Li-air battery related technologies. A comprehensive survey from a battery industry standpoint has been conducted on the fundamentals of chemistry, utilized Li-air cell configurations (or types) vs. performance, and major components comprising Li-air batteries using various sources of previously published peer-reviewed journal papers, book chapters, patents, and industrial reports. The survey results are presented here. (Copyright copyright 2012 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  7. Application of multicriteria decision making methods to air quality in the microenvironments of residential houses in Brisbane, Australia.

    Ayoko, Godwin A; Morawska, Lidia; Kokot, Serge; Gilbert, Dale

    2004-05-01

    This paper reports the first application of the multicriteria decision making methods, PROMETHEE and GAIA, to indoor and outdoor air quality data. Fourteen residential houses in a suburb of Brisbane, Australia were investigated for 21 air quality-influencing criteria, which included the characteristics of the houses as well as the concentrations of volatile organic compounds, fungi, bacteria, submicrometer, and supermicrometer particles in their indoor and outdoor air samples. Ranking information necessary to select one house in preference to all others and to assess the parameters influencing the differentiation of the houses was found with the aid of PROMETHEE and GAIA. There was no correlation between the rank order of each house and the health complaints of its occupants. Patterns in GAIA plots show that indoor air quality in these houses is strongly dependent on the characteristics of the houses (construction material, distance of the house from a major road, and the presence of an in-built garage). Marked similarities were observed in the patterns obtained when GAIA and factor analysis were applied to the data. This underscores the potential of PROMETHEE and GAIA to provide information that can assist source apportionment and elucidation of effective remedial measures for indoor air pollution.

  8. Dence Cold Matter

    Stavinskiy Alexey

    2014-04-01

    Full Text Available Possible way to create dense cold baryonic matter in the laboratory is discussed. The density of this matter is comparable or even larger than the density of neutron star core. The properties of this matter can be controlled by trigger conditions. Experimental program for the study of properties of dense cold matter for light and heavy ion collisions at initial energy range √sNN~2-3GeV is proposed..

  9. Energetic performances of an optimized passive Solar Heating Prototype used for Tunisian buildings air-heating application

    Mehdaoui, Farah; Hazami, Majdi; Naili, Nabiha; Farhat, Abdelhamid

    2014-01-01

    Highlights: • The study of a Solar Heating Prototype to prevail the buildings air-heating needs. • A parametric study of the system was achieved by means of the TRNSYS program. • The monthly internal temperature during cold months ranges between 22 and 25 °C. • The results shows that the relative humidity inside the monozone room of about 40%. - Abstract: This paper deals with the energetic performances of a Solar Heating Prototype (SHP) conceived in our laboratory to prevail the Tunisian households’ air-heating needs. The conceived SHP mainly consists of a flat-plate solar collector, solar hot water tank and an active layer integrated inside a single room. Firstly, a complete model is formulated taking into account various modes of heat transfer in the SHP by means of the TRNSYS simulation program. To validate the TRNSYS model, experimental tests under local weather conditions were performed for 2 days spread over 2 months (March and April 2013). Predicted results were compared to the measurements in order to determine the accuracy of the simulation program. A parametric study was then achieved by means of the TRNSYS program in order to optimize SHP design parameters (Collector area, collector mass flow rate, floor mass flow rate, storage tank volume and thickness of the active layer). The optimization of all design parameters shows that to achieve a maximum performances from the SHP it is essential to use a solar collector with an area equal to 6 m 2 area, a collector mass flow rate equal to 100 kg h −1 and a hot water storage tank with a capacity equal to 450 l. Concerning the floor heating, the optimal values of mass flow rate and the active layer thickness are 200 kg h −1 and 0.06 m, respectively. The long-term SHP performances were afterward evaluated by means of the Typical Meteorological Year (TMY) data relative to Tunis, Tunisia. Results showed that for an annual total solar insolation of about 6493.37 MJ m −2 the average solar fraction

  10. The Application of Online Check-in in the Process of Passenger Handling in Air Transportation

    František Adamčík

    2017-11-01

    Full Text Available Passenger handling is one of the most important activities any passenger is obliged to carry out prior to boarding the plane to depart. For the handling process to be safeguarded, it is inevitable to perform the services involved in it fast and efficiently so as to prevent idle times or delays during the procedures potentially resulting in delay of flight. By gradual development of the so-called web-based information technologies, some of the activities involved in the handling process can be delegated to the passengers themselves, thereby achieving a faster course of the passenger handling process. In this contribution the authors are dealing with the status quo of the on-line web-based check-in process in air transportation forecasting the expected course of events in these services in the future. Next, based on analyzing functions and characteristics of similar solutions available in the market, the authors are putting forward their new proposal of their own design of a self-service, on-line system of passenger handling with the aim to simplify and expedite the entire handling process. It is the aim of the authors to develop a competitive design in terms of costs as well as new function and services not offered by the hitherto existing with emphasis on improving efficiency of passenger handling at the airports. The resulting solution thanks to internet based technologies is platform independent and fully applicable to the process of airport passenger handling. To an equal extent, the solutions are being applied by the authors to the educational process, as a training tool for the preparation of the aviation personnel and also as part of simulation models for research in the field of airport processes optimization.

  11. The application of air pressure difference in reducing indoor radon concentration

    Leung, J.K.C.; Tso, M.Y.W.

    2000-01-01

    In densely populated tropical cities like Hong Kong, people usually live and work inside high-rise buildings. And because of the hot and humid climate, air conditioning systems are used throughout the year, particularly in commercial buildings. Previous territory-wide surveys have shown that over 10% of commercial buildings in Hong Kong have indoor radon concentrations above 200 Bq m -3 . Since the major source of indoor radon in high-rise buildings is the building materials, increasing ventilation and applying radon barriers on wall surfaces seem to be the only ways to reduce the indoor radon concentration. But it was noted that the ventilation rate the many commercial buildings are not efficient enough to remove the radon because of various reasons such as energy saving, lack of maintenance, etc. In this study, radon mitigation was achieved by reducing the rate of radon exhaled from the building materials. A special laboratory, which has the capability of simulating any meteorological conditions that could be faced by high-rise buildings in Hong Kong, was built. The reduction of radon exhalation rate by applying pressure difference and temperature difference across walls was studied in the laboratory. This paper summarizes the results and tactics for applying pressure difference in existing commercial buildings. A new technique of reducing radon exhalation rate in new buildings by depressurizing the interior of walls was also developed. Tunnels can be embedded in the concrete walls of new buildings during construction. By using simple vacuum pumps, radon exhalation rate from the walls can be reduced significantly by depressurizing the tunnels. The feasibility and applicability of the technique is presented in this paper. (author)

  12. Porous ZrO_2-TiO_2 ceramics for applications as sensing elements in the air humidity monitoring

    Oliveira, Rodrigo de Matos; Nono, Maria do Carmo de Andrade

    2011-01-01

    The environmental monitoring requires versatile, reliable and lower cost instruments. The chemical superficial absorption/adsorption capability of water molecules by several ceramic oxides makes them excellent candidates for this application. In this way, many efforts have been made for the development of porous ceramics, manufactured from mechanical mixture of ZrO_2 and TiO_2 powders, for application as air humidity sensing elements. The sintered ceramics were characterized as for crystalline phases (X-ray diffraction) and pores structure (scanning electron microscopy and mercury porosimetry). The relative humidity curves for the ceramics were obtained from measurements with RLC bridge in climatic chamber. The behavior of these curves were comparatively analyzed with the aid of pores sizes distribution curves, obtained through mercury porosimetry. The results evidenced that the air humidity ceramic sensing elements are very promising ones. (author)

  13. Enershield : energy saving air barriers

    Hallihan, D. [Enershield Industries Ltd., Edmonton, AB (Canada)

    2008-07-01

    Enershield Industries is a leader in air barrier technology and provides solution for the Canadian climate. This presentation described the advantages of air barriers and the impact of rising energy costs. An air barrier is used to separate areas of differing environments and makes existing building systems more efficient. This presentation discussed how an air barrier works. It also identified how Enershield Industries calculates energy savings. It described air barrier applications and those who use barrier technology. These include the commercial and industrial sector as well as the personnel and retail sector. Barrier technology can be used for cold storage; vehicle and equipment washes; food processing; and environmental separation. Features and benefits such as the ability to create seal, acoustic insulation, and long term durability were also discussed. Last, the presentation addressed model selection and design criteria issues. Design criteria that were presented included a discussion of acoustic installation, articulating nozzles, scroll cased fans, and structural frame. Other design criteria presented were galvanized frames, telescopic sliders, and off the shelf parts. It was concluded that the ability to reduce energy consumption and enhance employee/client comfort is beneficial to the employer as well as to the employee. figs.

  14. Exergy and energy analyses of two different types of PCM based thermal management systems for space air conditioning applications

    Tyagi, V.V.; Pandey, A.K.; Buddhi, D.; Tyagi, S.K.

    2013-01-01

    Highlights: ► Calcium chloride hexahydrate (CaCl 2 ⋅6H 2 O) as a PCM was used in this study. ► Two different capsulated system (HDPE based panel and balls) were designed. ► The results of CaCl 2 ⋅6H 2 O are very attractive for space air conditioning. ► Energy and exergy analyses for space cooling applications. - Abstract: This communication presents the experimental study of PCM based thermal management systems for space heating and cooling applications using energy and exergy analysis. Two different types of based thermal management system (TMS-I and TMS-II) using calcium chloride hexahydrate as the heat carrier has been designed, fabricated and studied for space heating and cooling applications at a typical climatic zone in India. In the first experimental arrangement the charging of PCM has been carried out with air conditioning system while discharging has been carried out using electric heater for both the thermal management systems. While in the second arrangement the charging of PCM has been carried out by solar energy and the discharging has been carried out by circulating the cooler ambient air during the night time. In the first experiment, TMS-I is found to be more effective than that of TMS-II while it was found to be reverse in the case of second experiment for both the charging and discharging processes not only for energetic but also for the exergetic performances

  15. Potable water recovery for spacecraft application by electrolytic pretreatment/air evaporation

    Wells, G. W.

    1975-01-01

    A process for the recovery of potable water from urine using electrolytic pretreatment followed by distillation in a closed-cycle air evaporator has been developed and tested. Both the electrolytic pretreatment unit and the air evaporation unit are six-person, flight-concept prototype, automated units. Significantly extended wick lifetimes have been achieved in the air evaporation unit using electrolytically pretreated, as opposed to chemically pretreated, urine feed. Parametric test data are presented on product water quality, wick life, process power, maintenance requirements, and expendable requirements.

  16. Chillers and cold water units. Special issue; Chillers en koudwateraggregaten. Thema

    Van Zwam, P. [GEA Refrigeration Components Benelux, Den Bosch (Netherlands); Meijer, W. [Daikin Airconditioning Netherlands, Rotterdam (Netherlands); Torsy, E. [Trane Airconditioning, Soest (Netherlands); Berends, E. [GEA Grenco Refrigeration, Den Bosch (Netherlands); Havenaar, D. (ed.)

    2010-05-15

    In five articles attention is paid to several aspects of chillers and cold water units: (1) reduction of refrigerants and increase of the COP; (2) realization of high partial load efficiency in mono-screw compressors; (3) energy efficient innovation for cooling and heat pump systems; (4) application of modern chiller technology for a skating rink of Sportboulevard, Dordrecht, Netherlands; and (5) the use of propane as a refrigerant in air-cooled cold water units. [Dutch] In vijf artikelen wordt aandacht besteed aan verschillende aspecten van chillers en koudwateraggregaten: (1) minimaliseren van koudemiddeleninhoud en verhogen van de COP; (2) realisatie van hoge deellastrendementen met mono-schroefcompressoren; (3) energie efficiente innovaties voor koelmachine- en warmtepompsystemen; (4) toepassing van moderne chillertechnologie in de ijshal van Sportboulevard Dordrecht; en (5) het gebruik van propaan als koudemiddel in luchtgekoelde koudwateraggregaten.

  17. Identification of the significant factors in food safety using global sensitivity analysis and the accept-and-reject algorithm: application to the cold chain of ham.

    Duret, Steven; Guillier, Laurent; Hoang, Hong-Minh; Flick, Denis; Laguerre, Onrawee

    2014-06-16

    Deterministic models describing heat transfer and microbial growth in the cold chain are widely studied. However, it is difficult to apply them in practice because of several variable parameters in the logistic supply chain (e.g., ambient temperature varying due to season and product residence time in refrigeration equipment), the product's characteristics (e.g., pH and water activity) and the microbial characteristics (e.g., initial microbial load and lag time). This variability can lead to different bacterial growth rates in food products and has to be considered to properly predict the consumer's exposure and identify the key parameters of the cold chain. This study proposes a new approach that combines deterministic (heat transfer) and stochastic (Monte Carlo) modeling to account for the variability in the logistic supply chain and the product's characteristics. The model generates a realistic time-temperature product history , contrary to existing modeling whose describe time-temperature profile Contrary to existing approaches that use directly a time-temperature profile, the proposed model predicts product temperature evolution from the thermostat setting and the ambient temperature. The developed methodology was applied to the cold chain of cooked ham including, the display cabinet, transport by the consumer and the domestic refrigerator, to predict the evolution of state variables, such as the temperature and the growth of Listeria monocytogenes. The impacts of the input factors were calculated and ranked. It was found that the product's time-temperature history and the initial contamination level are the main causes of consumers' exposure. Then, a refined analysis was applied, revealing the importance of consumer behaviors on Listeria monocytogenes exposure. Copyright © 2014. Published by Elsevier B.V.

  18. The analysis of 14.8 percent cold leg break without the application of hydroaccumulators in the PMK-NHV test facility

    Szabados, L.; Ezsoel, Gy.; Perneczky, L.

    1990-12-01

    A series of reactor safety tests have been performed in the experimental reactor simulation facility PMK-NHV of the Paks Nuclear Power Plant, Hungary, with and without the use of hydroaccumulator (SIT) operation. 14.8 percent cold leg break simulation experiments are reported without SITs in action, and the measurement results were analyzed using the RELAP5/mod2 computer code. The description of the experiment is followed by the parameter variations and their analysis, together with an interpretation of the measurement results. The lessons from the LOCA simulation tests are evaluated. (R.P.) 10 refs.; 48 figs.; 3 tabs

  19. A coupled diffusion-transport computational method and its application for the determination of space dependent angular flux distributions at a cold neutron source

    Turgut, M.H.

    1985-01-01

    A fast calculation program ''BRIDGE'' was developed for the calculation of a Cold Neutron Source (CNS) at a radial beam tube of the FRG-I reactor, which couples a total assembly diffusion calculation to a transport calculation for a certain subregion. For the coupling flux and current boundary values at the common surfaces are taken from the diffusion calculation and are used as driving conditions in the transport calculation. 'Equivalence Theorie' is used for the transport feedback effect on the diffusion calculation to improve the consistency of the boundary values. The optimization of a CNS for maximizing the subthermal flux in the wavelength range 4 - 6 A is discussed. (orig.) [de

  20. Rietveld and impedance analysis of cold and hot rolled duplex and lean duplex steels for application in paper and pulp industry

    Esteves, Luiza; Lins, Vanessa de Freitas Cunha, E-mail: luizaeq@yahoo.com.br [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil). Departamento de Engenharia Quimica; Paiva, Paulo Renato Perdigao [Centro Federal de Educacao Tecnologica de Minas Gerais (CEFET), Belo Horizonte, MG (Brazil); Viana, Adolfo Kalergis do Nascimento [APERAM South America, Timoteo, MG (Brazil)

    2017-01-15

    In this study, X-Ray Diffraction (XRD) and Rietveld Refinement were performed to identify and quantify the ferrite and austenite phase of cold and hot rolled duplex stainless steels (UNS S31803) and lean duplex stainless steels (UNS S32304). Electrochemical impedance spectroscopy (EIS) was applied to evaluate the chemical behavior of duplex and lean duplex stainless steels in white, green, and black liquors of paper and pulp industry. Rietveld analysis results showed a higher austenite content than the standard limit for duplex steels in the hot rolled condition. The hot rolling condition plays a major role in improving corrosion resistance in white liquor mainly for the lean duplex steel. (author)

  1. Rietveld and impedance analysis of cold and hot rolled duplex and lean duplex steels for application in paper and pulp industry

    Esteves, Luiza; Lins, Vanessa de Freitas Cunha; Viana, Adolfo Kalergis do Nascimento

    2017-01-01

    In this study, X-Ray Diffraction (XRD) and Rietveld Refinement were performed to identify and quantify the ferrite and austenite phase of cold and hot rolled duplex stainless steels (UNS S31803) and lean duplex stainless steels (UNS S32304). Electrochemical impedance spectroscopy (EIS) was applied to evaluate the chemical behavior of duplex and lean duplex stainless steels in white, green, and black liquors of paper and pulp industry. Rietveld analysis results showed a higher austenite content than the standard limit for duplex steels in the hot rolled condition. The hot rolling condition plays a major role in improving corrosion resistance in white liquor mainly for the lean duplex steel. (author)

  2. Data Supporting Mobile Application Development for Use within the Marine Air-Ground Task Force

    2015-09-01

    Unhelkar & Murugesan, 2010) ............................................................. 36   Figure 7.   Starbucks iPhone payment application (from... Starbucks , 2015) .......... 38   Figure 8.   The Mobile Applications Development Framework (from Unhelkar & Murugesan, 2010...application (Unhelkar & Murugesan, 2010). Retailer-developed electronic 38 payment applications such as the Starbucks iPhone application (see Figure 7

  3. The lab and the land: overcoming the Arctic in Cold War Alaska.

    Farish, Matthew

    2013-03-01

    The militarization of Alaska during and after World War II created an extraordinary set of new facilities. But it also reshaped the imaginative role of Alaska as a hostile environment, where an antagonistic form of nature could be defeated with the appropriate combination of technology and training. One of the crucial sites for this reformulation was the Arctic Aeromedical Laboratory, based at Ladd Air Force Base in Fairbanks. In the first two decades of the Cold War, its employees conducted numerous experiments on acclimatization and survival. The laboratory is now best known for an infamous set of tests involving the application of radioactive tracers to indigenous Alaskans--experiments publicized by post-Cold War panels established to evaluate the tragic history of atomic-era human subject research. But little else has been written about the laboratory's relationship with the populations and landscapes that it targeted for study. This essay presents the laboratory as critical to Alaska's history and the history of the Cold War sciences. A consideration of the laboratory's various projects also reveals a consistent fascination with race. Alaskan Natives were enrolled in experiments because their bodies were understood to hold clues to the mysteries of northern nature. A scientific solution would aid American military campaigns not only in Alaska, but in cold climates everywhere.

  4. 2012 German refrigeration and air conditioning meeting. Proceedings; Deutsche Kaelte-Klima-Tagung 2012 Tagungsbericht

    NONE

    2012-07-01

    Within the DKV conference of the Deutscher Kaelte- und Klimatechnischer Verein e.V. (Hanover, Federal Republic of Germany) from 21st to 23rd November, 2012, in Wuerzburg (Federal Republic of Germany) 121 lectures were held according to the following themes: Measurement and process control in cryotechnology; energy storage and energy application; application of cryotechnology in biology and medicine, new concepts and plants; fundamentals and materials for the technology of cold pumps and heat pumps - pool boiling; flow boiling / CO{sub 2}; adsorption processes; adsorption processes / phase change materials; condensation / dehumidification; plants and components of the technology of cold pumps and heat pumps - compressors; expansion and regulation; heat exchanger and reflux cooling; heat exchangers; systems simulation; systems and materials; application of cold - energy controlling / application; foodstuff / supermarket; air conditionings of passenger cars; air-conditioning of electric-powered automobiles; railway air-conditioning / system analyses; standardization and regulations; air conditioning and application of heat pumps - regulation / hardware-in-the-loop; net-zero-energy building; building engineering and simulation; standardization / IAQ / building materials; heat pumps; thermal comfort and performance in office accommodations.

  5. Cold moderators at ORNL

    Lucas, A. T.

    1997-09-01

    The Advanced Neutron Source (ANS) cold moderators were not an 'Oak Ridge first', but would have been the largest both physically and in terms of cold neutron flux. Two cold moderators were planned each 410 mm in diameter and containing about 30L of liquid deuterium. They were to be completely independent of each other. A modular system design was used to provide greater reliability and serviceability. When the ANS was terminated, upgrading of the resident High Flux Isotope Reactor (HFIR) was examined and an initial study was made into the feasibility of adding a cold source. Because the ANS design was modular, it was possible to use many identical design features. Sub-cooled liquid at 4 bar abs was initially chosen for the HFIR design concept, but this was subsequently changed to 15 bar abs to operate above the critical pressure. As in the ANS, the hydrogen will operate at a constant pressure throughout the temperature range and a completely closed loop with secondary containment was adopted. The heat load of 2 kW made the heat flux comparable with that of the ANS. Subsequent studies into the construction of cryogenic moderators for the proposed new Synchrotron Neutron source indicated that again many of the same design concepts could be used. By connecting the two cold sources together in series, the total heat load of 2 kW is very close to that of the HFIR allowing a very similar supercritical hydrogen system to be configured. The two hydrogen moderators of the SNS provide a comparable heat load to the HFIR moderator. It is subsequently planned to connect the two in series and operate from a single cold loop system, once again using supercritical hydrogen. The spallation source also provided an opportunity to re-examine a cold pellet solid methane moderator operating at 20K.

  6. Aerosol composition and its application in air pollution monitoring. Appendix 10

    Sadasivan, S.; Negi, B.S.; Meenakshy, V.; Nambi, K.S.V.

    1995-01-01

    Air particulate matter was sampled in two size ranges, 2-10 μm and -3 in -3 . Results of elemental emission profile were obtained by burning different domestic fuels in specially built oven and results are presented. (author)

  7. Rapid evolution of air pollution sensor technology for research and consumer product applications

    Outdoor air pollution measurement approaches have historically been conducted using stationary shelters that require significant space, power, and expertise to operate. The cost and logistical requirements to conduct monitoring have limited the number of locations with continuou...

  8. Applications of Arbitrary Lagrangian Eulerian (ALE) Analysis Approach to Underwater and Air Explosion Problems

    Trevino, Theodore

    2000-01-01

    ...) numerical technique. The investigation primarily examined the explosive-fluid, fluid-structure, and fluid-air interaction effects, and the shock wave pressure propagation through a subjected medium, with the intent...

  9. Remote sensing applications of wildland fire and air quality in China

    John J. Qu; Xianjun Hao; Yongqiang Liu; Allen R. Riebau; Haoruo Yi; Xianlin Qin

    2009-01-01

    As one of the most populous and geographically largest countries, China faces many problems including industrial growth, economic sustainability, food security, climate change, and air pollution. Interwoven with these challenges,...

  10. The application of fuzzy control on energy saving for multi-unit room air-conditioners

    Chiou, C.B.; Chiou, C.H.; Chu, C.M.; Lin, S.L.

    2009-01-01

    Most research, on energy saving methods for air-conditioners have focused on large chillers as its subject. As most school offices, laboratories, and classrooms are equipped with unitary systems for air-conditioning, this paper discusses methods for energy savings with regard to unitary systems. This paper will put forward the fuzzy temperature control method for multi-unit air-conditioners to enhance energy efficiency. The results show that the use of fuzzy control is efficient for energy saving as well as causing temperature control be steadier, even if there is a change to the thermal loading, the fuzzy control system is able to control the air-conditioning in stable conditions

  11. Deployable Engine Air-Brake for Drag Management Applications, Phase I

    National Aeronautics and Space Administration — ATA Engineering, Inc, proposes an SBIR program to demonstrate an innovative engine air-brake (EAB) technology that uses a deployable swirl vane mechanism to switch...

  12. Deployable Engine Air-Brake for Drag Management Applications, Phase II

    National Aeronautics and Space Administration — ATA Engineering, Inc., (ATA) proposes a Phase II SBIR program to demonstrate an innovative engine air-brake (EAB) technology that uses a deployable swirl vane...

  13. Robust and Air-Stable Sandwiched Organo-Lead Halide Perovskites for Photodetector Applications

    Mohammed, Omar F.; Banavoth, Murali; Saidaminov, Makhsud I.; Abdelhady, Ahmed L.; Pan, Jun; Liu, Jiakai; Peng, Wei; Bakr, Osman

    2016-01-01

    We report the simplest possible method to date for fabricating robust, air-stable, sandwiched perovskite photodetectors. Our proposed sandwiched structure is devoid of electron or hole transporting layers and also the expensive electrodes

  14. Development of an Engine Air-Brake for Quiet Drag Applications, Phase I

    National Aeronautics and Space Administration — A novel quiet engine air-brake is proposed in response to NASA's solicitation for concepts for active and passive control of noise sources for conventional and...

  15. Technology Transfer: A Qualitative Analysis of Air Force Office of Research and Technology Applications

    Trexler, David C

    2006-01-01

    Everyday within United States Air Forces? research laboratories there are hundreds of scientists and engineers whose research and development activities contribute to the advancement of science and technology for mankind...

  16. APPLICATION OF BAYESIAN MONTE CARLO ANALYSIS TO A LAGRANGIAN PHOTOCHEMICAL AIR QUALITY MODEL. (R824792)

    Uncertainties in ozone concentrations predicted with a Lagrangian photochemical air quality model have been estimated using Bayesian Monte Carlo (BMC) analysis. Bayesian Monte Carlo analysis provides a means of combining subjective "prior" uncertainty estimates developed ...

  17. Application of an image intensifier to the study on hadrons in air shower, 4

    Tsushima, Itsuro; Kawasumi, Norio; Hashimoto, Katsumi; Machida, Masaharu

    1975-01-01

    As the apparatus for observing cosmic ray air shower, the particle detection apparatus combining spark chamber, scintillator and photomultiplier tube is frequently used, but the exact detection of particle number is impossible with it when particle density is large. The authors have carried out the experiment to measure nuclear active particles in air shower and to grasp the central part of air shower as energy flow by utilizing an image intensifier tube. On the roof of building S, a laboratory was built, and a core detector of 2 m x 2 m area, 13 AS detectors of 0.25 m 2 and an AS detector of 1 m 2 were installed. The gate of the II was opened by utilizing coincidence pulses, and the position and amount of scintillation in the core detector was taken into a camera through the II. The time of observation was 289 hours, and the time of II operation was 113 hours. Total number of air shower recorded was 218 cases, and the centers of 120 cases among them were determined in the AS detectors at four corners. The centers of 39 cases were within the area of the core detector. In the coincident counting of air shower and burst carried out in the present experiment, the total delay time from the arrival of air shower to the gate pulse actuating the II was 1.6 sec. The core of air shower of about 10 6 size and 1.3 age was caught by this method. The problems for future are the determination of core position for the air shower of smaller size, and the meaning of spot images of II. (Kako, I.)

  18. The Application of Work Domain Analysis to Defining Australia’s Air Combat Capability

    2014-03-01

    Capability. References Brady, A., Naikar, N., & Treadwell, A. (2013). Organisational storytelling with work domain analysis: Case study of air power...UNCLASSIFIED 20 Brady, A., Naikar, N., & Treadwell, A. (2013). Organisational storytelling with work domain analysis: Case study of air power doctrine and...maturity model? A framework of general design principles for maturity model and its demonstration in business process management. Proceedings of the

  19. Oxygen Plasma Treatment of Rubber Surface by the Atmospheric Pressure Cold Plasma Torch

    Lee, Bong-ju; Kusano, Yukihiro; Kato, Nobuko

    1997-01-01

    adhesive. The adhesion property was improved by treatment of the rubber compound with plasma containing oxygen radicals. Physical and chemical changes of the rubber surface as a result of the plasma treatment were analyzed by field emission scanning electron microscopy (FE-SEM) and fourier transform......A new application of the atmospheric cold plasma torch has been investigated. Namely, the surface treatment of an air-exposed vulcanized rubber compound. The effect of plasma treatment was evaluated by the bondability of the treated rubber compound with another rubber compound using a polyurethane...

  20. Aeronautical Communications Research and Development Needs for Future Air Traffic Management Applications

    Kerczewski, Robert J.

    2002-01-01

    Continuing growth in regional and global air travel has resulted in increasing traffic congestion in the air and on the ground. In spite of occasional temporary downturns due to economic recessions and catastrophic events, average growth rates of air travel have remained high since the 1960s. The resulting congestion, which constrains expansion of the air transportation industry, inflicts schedule delays and decreases overall system efficiency, creating a pressing need to develop more efficient methods of air traffic management (ATM). New ATM techniques, procedures, air space automation methods, and decision support tools are being researched and developed for deployment in time frames stretching from the next few years to the year 2020 and beyond. As these methods become more advanced and increase in complexity, the requirements for information generation, sharing and transfer among the relevant entities in the ATM system increase dramatically. However, current aeronautical communications systems will be inadequate to meet the future information transfer demands created by these advanced ATM systems. Therefore, the NASA Glenn Research Center is undertaking research programs to develop communication, methods and key technologies that can meet these future requirements. As part of this process, studies, workshops, testing and experimentation, and research and analysis have established a number of research and technology development needs. The purpose of this paper is to outline the critical research and technology needs that have been identified in these activities, and explain how these needs have been determined.