WorldWideScience

Sample records for coincidence measurements bestimmung

  1. Criteria of validity in the measurement of shearing fracture toughness; Gueltigkeitskriterien zur Bestimmung von Scherbruchzaehigkeiten

    Energy Technology Data Exchange (ETDEWEB)

    Hiese, W

    2000-01-01

    The investigations aimed at the development of criteria for measuring valid shearing fracture toughness data K{sub IIc} in analogy to the measurement of mode-I fracture toughness K{sub Ie}. Details are presented, and practical recommendations are given. [German] Die Brucheigenschaften von Werkstoffen werden ueblicherweise unter Zugbeanspruchungsbedingungen (Mode-I) bestimmt. Im Anwendungsbereich der linear-elastischen Bruchmechanik bzw. des Kleinbereichsfliessens geschieht dieses in Form der Bruchzaehigkeit K{sub Ic}. Es existieren entsprechende Richtlinien zur Durchfuehrung des Tests sowie zur Registrierung und Auswertung der Daten. Diese Kriterien sind in Standards festgelegt. Empfehlungen zur Bestimmung der Bruchzaehigkeit K{sub IIc} unter ebener Scherbelastung (Mode-II) fuer Werkstoffe mit im wesentlichen linear-elastischem Verhalten existieren nicht. Im Rahmen dieser Arbeit werden durch den Vergleich der Groesse der plastischen Rissspitzenzonen im Verhaeltnis zu den Abmessungen von Probe bzw. Bauteil Kriterien zur Messung gueltiger Scherbruchzaehigkeiten K{sub IIc} analog zur Messung der Mode-I-Bruchzaehigkeit K{sub Ic} entwickelt. Der Groessenvergleich der plastischen Rissspitzenzonen fuer beide Beanspruchungsarten zeigt unter aequivalenten Beanspruchungen, d.h. K{sub II}=K{sub I}, dass bei Mode-II beanspruchten Rissen die plastischen Zonen groesser, aber die Differenzen in der Groesse der plastischen Zonen fuer die Zustaende ebener Spannung und ebener Dehnung kleiner sind als unter entsprechenden Mode-I-Beanspruchungen.

  2. Coincidence measurements of FFTF breeder fuel subassemblies

    International Nuclear Information System (INIS)

    Eccleston, G.W.; Foley, J.E.; Krick, M.; Menlove, H.O.; Goris, P.; Ramalho, A.

    1984-04-01

    A prototype coincidence counter developed to assay fast breeder reactor fuel was used to measure four fast-flux test facility subassemblies at the Hanford Engineering Development Laboratory in Richland, Washington. Plutonium contents in the four subassemblies ranged between 7.4 and 9.7 kg with corresponding 240 Pu-effective contents between 0.9 and 1.2 kg. Large count rates were observed from the measurements, and plots of the data showed significant multiplication in the fuel. The measured data were corrected for deadtime and multiplication effects using established formulas. These corrections require accurate knowledge of the plutonium isotopics and 241 Am content in the fuel. Multiplication-corrected coincidence count rates agreed with the expected count rates based on spontaneous fission-neutron emission rates. These measurements indicate that breeder fuel subassemblies with 240 Pu-effective contents up to 1.2 kg can be nondestructively assayed using the shift-register electronics with the prototype counters. Measurements using the standard Los Alamos National Laboratory shift-register coincidence electronics unit can produce an assay value accurate to +-1% in 1000 s. The uncertainty results from counting statistics and deadtime-correction errors. 3 references, 8 figures, 8 tables

  3. Determining chance coincidence, survival factor and decay factor in 220Rn delayed coincidence measurement

    International Nuclear Information System (INIS)

    Huang Derong; Yan Yongjun; Zhou Jianliang; Qiu Shoukang

    2013-01-01

    The method and calculation formulas to determine the chance coincidence in the 220 Rn coincidence measurement are introduced in this paper. The poisson distribution is introduced to correct the chance coincidence. The relative deviation of the true coincidence between the method and the Giffin's is within 5% after the correction of the cohance coincidence. The measurement of 220 Rn is done by comparative measurement with RAD7. The results shows that 220 Rn can be measured by the method with a relative deviation of 14%. Mean while, for the 220 Rn flow regime is difficult to meet the condition of calculation formulas, a solution to solve the survival factor and decay factor is proposed and the error come from the useage of theoretical calculation formula is avoided. (authors)

  4. Principle of coincidence method and application in activity measurement

    International Nuclear Information System (INIS)

    Li Mou; Dai Yihua; Ni Jianzhong

    2008-01-01

    The basic principle of coincidence method was discussed. The basic principle was generalized by analysing the actual example, and the condition in theory of coincidence method was brought forward. The cause of variation of efficiency curve and the effect of dead-time in activity measurement were explained using the above principle and condition. This principle of coincidence method provides the foundation in theory for activity measurement. (authors)

  5. Data acquisition and processing system for coincidence measurements

    International Nuclear Information System (INIS)

    Li Xu

    1990-07-01

    An instrument has been designed for the absolute measurement of radioactivity with 4πβ(PC)-γ coincidence. The instrument can be used as a standard device for the radioactivity measurement in metrology laboratories. Also it can be used in the nuclear science and engineering research for absolute measurement of nuclear decay rate. The control of the system dead time and coincidence resolving time is digitized. The precision can reach ±2 ns. For data acquisition and communication the normalizing GPIB interface system technique is adopted. The measuring error caused by this instrument itself can be better than ±0.02%

  6. Chemical application of positron annihilation through triple coincidence measurement

    International Nuclear Information System (INIS)

    Yegnasubramanian, S.; Gangadharan, S.

    1982-01-01

    This report summarises the work on the application of triple coincidence measurement of annihilation radiation for providing chemical state information; the observations have been corroborated by angular correlation and Doppler broadening measurements and supplemented by the magnetic quenching in the angular correlation and peak-to-valley ratio in the Ge(Li) singles spectrum for the 511 keV line. (author)

  7. Photoion Auger-electron coincidence measurements near threshold

    International Nuclear Information System (INIS)

    Levin, J.C.; Biedermann, C.; Keller, N.; Liljeby, L.; Short, R.T.; Sellin, I.A.; Lindle, D.W.

    1990-01-01

    The vacancy cascade which fills an atomic inner-shell hole is a complex process which can proceed by a variety of paths, often resulting in a broad distribution of photoion charge states. We have measured simplified argon photoion charge distributions by requiring a coincidence with a K-LL or K-LM Auger electron, following K excitation with synchrotron radiation, as a function of photon energy, and report here in detail the argon charge distributions coincident with K-L 1 L 23 Auger electrons. The distributions exhibit a much more pronounced photon-energy dependence than do the more complicated non-coincident spectra. Resonant excitation of the K electron to np levels, shakeoff of these np electrons by subsequent decay processes, double-Auger decay, and recapture of the K photoelectron through postcollision interaction occur with significant probability. 17 refs

  8. A training and educational tool for neutron coincidence measurements

    International Nuclear Information System (INIS)

    Huszti, J.; Bagi, J.; Langner, D.

    2009-01-01

    Neutron coincidence counting techniques are widely used for nuclear safeguards inspection. They are based on the detection of time correlated neutrons created from spontaneous or induced fission of plutonium and some other actinides. IAEA inspectors are trained to know and to use this technique, but it is not easy to illustrate and explain the basics of the neutron coincidence counting. The traditional shift registers or multiplicity counters give only multiplicity distributions and the singles, doubles and triples count rates. Using the list mode method for the recording and evaluation of neutron coincidence data makes it easier to teach this technique. List mode acquisition is a relatively new way to collect data in neutron coincidence counting. It is based on the recording of the follow-up times of neutron pulses originating from a neutron detector into a file. The recorded pulse train can be evaluated with special software after the measurement. Hardware and software for list mode neutron coincidence acquisition have been developed in the Institute of Isotopes and is called a Pulse Train Reader. A system called Virtual Source for replaying pulse trains registered with the list mode device has also been developed. The list mode device and the pulse train 're-player' together build a good educational tool for teaching the basics of neutron coincidence counting. Some features of the follow-up time, multiplicity and Rossi-alpha distributions can be well demonstrated by replaying artificially generated or pre-recorded pulse trains. The choice of real sources is stored on DVD. There is no need to transport and maintain real sources for the training. Virtual sources also give the possibility of investigating rare sources that trainees would not have access to otherwise. (authors)

  9. Passive Time Coincidence Measurements with HEU and DU Metal Castings

    International Nuclear Information System (INIS)

    McConchie, Seth M.; Hausladen, Paul; Mihalczo, John T.; Wright, Michael C.; Archer, Daniel E.

    2008-01-01

    A Department of Energy sponsored Oak Ridge National Laboratory/Y-12 National Security Complex program of passive time coincidence measurements has been initiated at Y-12 to evaluate the ability to determine the presence of high enriched uranium (HEU) and distinguish it from depleted uranium (DU). This program uses the Nuclear Materials Identification System (NMIS) without an active interrogation source. Previous passive NMIS measurements with Pu metal and Pu oxide have been successful in determining the Pu mass, assuming a known 240Pu content. The spontaneous fission of uranium metal is considerably lower than Pu and measurements of this type have been performed at Lawrence Livermore National Laboratory. This work presents results of measurements of HEU and DU metal castings using moderated 3He detectors.

  10. The spallation in reverse kinematics: what for a coincidence measurement?

    International Nuclear Information System (INIS)

    Ducret, J.E.

    2006-07-01

    The Spaladin installation has been designed to study spallation reactions in reverse kinematics. Furthermore, the heavy and light fragments are detected by coincidence which allows us to get an instantaneous picture of the reaction at a level of accuracy better than that obtained through inclusive measurement. The first part is dedicated to the theoretical description of the different mechanisms involved in the spallation reactions. In the second part we describe the Spaladin installation and report some results on the reaction: Fe 56 + p at an energy of 1 GeV/nucleon. In the third part we expose the performance of the installation through its simulation with the Geant-IV model. We present a study about the sensitivity of the Spaladin installation to theoretical predictions. The fourth part is dedicated to the future experiments that will be performed with the Spaladin installation. (A.C.)

  11. Comparative study of chance coincidence correction in measuring 223Ra and 224Ra by delay coincidence method

    International Nuclear Information System (INIS)

    Yan Yongjun; Huang Derong; Zhou Jianliang; Qiu Shoukang

    2013-01-01

    The delay coincidence measurement of 220 Rn and 219 Rn has been proved to be a valid indirect method for measuring 224 Ra and 223 Ra extracted from natural water, which can provide valuable information on estuarine/ocean mixing, submarine groundwater discharge, and water/soil interactions. In practical operation chance coincidence correction must be considered, mostly Moore's correction method, but Moore's and Giffin's methods were incomplete in some ways. In this paper the modification (method 1) and a new chance coincidence correction formula (method 2) were provided. Experiments results are presented to demonstrate the conclusions. The results show that precision is improved while counting rate is less than 70 min- 1 . (authors)

  12. Measurement of plutonium oxalate in thermal neutron coincidence counters

    International Nuclear Information System (INIS)

    Marshall, R.S.; Erkkila, B.H.

    1979-01-01

    A coincidence neutron counting method has been developed for assaying batches of plutonium oxalate. Using counting data from two concentric rings of 3 He detectors, corrections are made for the effects that water has on the coincidence neutron count rate. Batches of plutonium oxalate varying from 750 to 1000 g of plutonium and from 34 to 54% water are assayed with an average accuracy of +-3%

  13. The development and application of a coincidence measurement apparatus with micro-computer system

    International Nuclear Information System (INIS)

    Du Hongshan; Zhou Youpu; Gao Junlin; Qin Deming; Cao Yunzheng; Zhao Shiping

    1987-01-01

    A coincidence measurement apparatus with micro-computer system is developed. Automatic data acquisition and processing are achieved. Results of its application for radioactive measurement are satisfactory

  14. Active method of neutron time correlation coincidence measurement to authenticate mass and enrichment of uranium metal

    International Nuclear Information System (INIS)

    Zhang Songbai; Wu Jun; Zhu Jianyu; Tian Dongfeng; Xie Dong

    2011-01-01

    The active methodology of time correlation coincidence measurement of neutron is an effective verification means to authenticate uranium metal. A collimated 252 Cf neutron source was used to investigate mass and enrichment of uranium metal through the neutron transport simulation for different enrichments and different masses of uranium metal, then time correlation coincidence counts of them were obtained. By analyzing the characteristic of time correlation coincidence counts, the monotone relationships were founded between FWTH of time correlation coincidence and multiplication factor, between the total coincidence counts in FWTH for time correlation coincidence and mass of 235 U multiplied by multiplication factor, and between the ratio of neutron source penetration and mass of uranium metal. Thus the methodology to authenticate mass and enrichment of uranium metal was established with time correlation coincidence by active neutron investigation. (authors)

  15. Design and test of 4πβ-γ coincidence measurement device based on DSP technology

    International Nuclear Information System (INIS)

    Zeng Herong; Feng Qijie; Leng Jun; Qian Dazhi; Bai Lixin; Zhang Yiyun

    2012-01-01

    The paper illustrates the hardware and software of the 4πβ-γ coincidence measurement device based on DSP technology in detail. In such device, the single-channel analyzer, gate generator, coincidence circuit and scalar in the traditional coincidence measurement device are replaced by the digital coincidence acquirer which is researched and manufactured by ourselves. Doing so, the measurement efficiency will be respectively improved, and the hardware cost will be lowered. The comparison experiment shows that the design of such device is a success. (authors)

  16. True coincidence-summing corrections for the coincident γ-rays measured with coplanar grid CdZnTe detectors

    International Nuclear Information System (INIS)

    Yuecel, H.; Solmaz, A.N.; Koese, E.; Bor, D.

    2010-01-01

    In this study, true coincidence-summing (TCS) correction factors have been measured for the sources 22 Na, 60 Co, 133 Ba and 152 Eu by use of three large volume coplanar grid CdZnTe (acronym: CZT) detectors. In case of a close-in detection geometry, two different TCS calculation algorithms were used to compute the required TCS correction factors. Both of the algorithms are based on the measured total-to-peak (TTP) ratio and full-energy peak (FEP) efficiency values that were obtained using almost 'single' energy and coincidence-free nuclides. The results for TCS correction factors obtained by two different algorithms were agreeable to each other. The obtained TCS factors were ranged from about 7% to 30.5% in a 2250 mm 3 CZT detector when a close counting geometry was used. For other two detectors with a volume of 1000 and 1687.5 mm 3 , the resulted TCS correction factors were relatively smaller and varied between about 0.1% and 20% at the close counting geometry condition. Therefore, the results indicate that there is a need for the estimation of TCS corrections in CZT detectors, especially when their crystal volumes are greater than 1 cm 3 and these detectors are used in the case of a close-in detection geometry.

  17. First principle active neutron coincidence counting measurements of uranium oxide

    Energy Technology Data Exchange (ETDEWEB)

    Goddard, Braden, E-mail: goddard.braden@gmail.com [Nuclear Security Science and Policy Institute, Texas A and M University, College Station, Texas 77843 (United States); Charlton, William [Nuclear Security Science and Policy Institute, Texas A and M University, College Station, Texas 77843 (United States); Peerani, Paolo [European Commission, EC-JRC-ITU, Ispra (Italy)

    2014-03-01

    Uranium is present in most nuclear fuel cycle facilities ranging from uranium mines, enrichment plants, fuel fabrication facilities, nuclear reactors, and reprocessing plants. The isotopic, chemical, and geometric composition of uranium can vary significantly between these facilities, depending on the application and type of facility. Examples of this variation are: enrichments varying from depleted (∼0.2 wt% {sup 235}U) to high enriched (>20 wt% {sup 235}U); compositions consisting of U{sub 3}O{sub 8}, UO{sub 2}, UF{sub 6}, metallic, and ceramic forms; geometries ranging from plates, cans, and rods; and masses which can range from a 500 kg fuel assembly down to a few grams fuel pellet. Since {sup 235}U is a fissile material, it is routinely safeguarded in these facilities. Current techniques for quantifying the {sup 235}U mass in a sample include neutron coincidence counting. One of the main disadvantages of this technique is that it requires a known standard of representative geometry and composition for calibration, which opens up a pathway for potential erroneous declarations by the State and reduces the effectiveness of safeguards. In order to address this weakness, the authors have developed a neutron coincidence counting technique which uses the first principle point-model developed by Boehnel instead of the “known standard” method. This technique was primarily tested through simulations of 1000 g U{sub 3}O{sub 8} samples using the Monte Carlo N-Particle eXtended (MCNPX) code. The results of these simulations showed good agreement between the simulated and exact {sup 235}U sample masses.

  18. Studies on the true coincidence correction in measuring filter samples by gamma spectrometry

    CERN Document Server

    Lian Qi; Chang Yong Fu; Xia Bing

    2002-01-01

    The true coincidence correction in measuring filter samples has been studied by high efficiency HPGe gamma detectors. The true coincidence correction for a specific three excited levels de-excitation case has been analyzed, and the typical analytical expressions of true coincidence correction factors have been given. According to the measured relative efficiency on the detector surface with 8 'single' energy gamma emitters and efficiency of filter samples, the peak and total efficiency surfaces are fitted. The true coincidence correction factors of sup 6 sup 0 Co and sup 1 sup 5 sup 2 Eu calculated by the efficiency surfaces agree well with experimental results

  19. Devising a measuring system for the determination of diffusion coefficients in biofilm; Entwicklung eines Messsystems zur Bestimmung von Diffusionskoeffizienten im Biofilm

    Energy Technology Data Exchange (ETDEWEB)

    Berndt, K. [Fachhochschule Magdeburg (Germany). Fachbereich Chemie; Horn, H. [Fachhochschule Magdeburg (Germany). Hydro- und Abfallchemie

    1999-07-01

    The diffusion coefficient of a substrate in a biofilm is an important parameter for simulating mass turnover and transport in biofilm systems. The described method permits determining the diffusion coefficients in biofilms grown under defined substrate and hydrodynamic conditions in a laboratory reactor. (orig.) [German] Der Diffusionskoeffizient des Substrats in Biofilmen ist ein wichtiger Parameter fuer die Simulation von Stoffwechsel und -transport in Biofilmsystemen. Die dargestellte Methode erlaubt die Bestimmung des Diffusionskoeffizienten in Biofilmen, die unter definierten Substrat- und hydrodynamischen Bedingungen in einem Laborreaktor gewachsen sind. (orig.)

  20. Measurement of in-cylinder mixture formation by optical indication; Bestimmung der innermotorischen Gemischbildung durch optisches Indizieren

    Energy Technology Data Exchange (ETDEWEB)

    Berg, Thomas; Thiele, Olaf; Seefeldt, Stefan [LaVision GmbH, Goettingen (Germany); Vanhaelst, Robin [Ostfalia Hochschule fuer Angewandte Wissenschaften, Wolfsburg (Germany). Fakultaet Fahrzeugtechnik

    2013-06-01

    The company LaVision has developed an optical indication process that can be used to determine lambda, residual gas and temperature curves in the combustion chamber with high temporal resolution. The sensor system is able to provide crank angle-resolved, real-time measurements of the complete process of in-cylinder mixture formation over hundreds of single cycles. (orig.)

  1. Electronic measurement equipment for determining the cloud cover of the sky. Elektronisches Messgeraet zur Bestimmung des Bedeckungsgrades des Himmels

    Energy Technology Data Exchange (ETDEWEB)

    Siebrasse, R

    1990-01-18

    The invention is used for the automatic determination of the degree of cloud cover of the sky. Compared to the state of the art, the invention has the advantage that it manages without mechanical controls, like those of 'sky scanners' for example, and that the measuring head has a very simple, cheap and robust construction. In order to do without any mechanics, a group of 24 photo-transistors of type BPX 43 was mounted on a hemispherical support, which screens the individual elements from one another, so that a certain section of the sky is allocated to each transistor. The optical axes of the individual axes are distributed completely evenly, so that there is an even and beam-shaped alignment to the sky above the measurement head. The individual measurements of the 24 transistors together give a certain optical impression, a 'picture' or a brightness distribution of the sky hemisphere, which can be read by a suitable program via a normal commercial adaptor into a personal computer, where this distribution is compared with given distributions which have degrees of cover of 0-8 or 0-10 as heading. The given 'picture' which comes closest to the current distribution is ejected as the result, and the heading of this picture gives the current degree of cloud cover.

  2. Improving Quality Of Spectrum Measurement By Event - Event Coincidence Technique

    International Nuclear Information System (INIS)

    Pham Dinh Khang; Doan Trong Thu; Nguyen Duc Hoa; Nguyen An Son; Nguyen Xuan Hai; Ho Huu Thang

    2011-01-01

    To improve the quality of measurement data for the research levels density and gamma strength function in intermediate energy region below the neutron binding energy (B n ), a new method was developed at the Dalat Nuclear Research Institute. This method improve the ratio of the count of peak per compton background more times. This results are evaluated, compared with other methods. (author)

  3. A method for measuring the energy spectrum of coincidence events in positron emission tomography.

    Science.gov (United States)

    Goertzen, Andrew L; Stout, David B; Thompson, Christopher J

    2010-01-21

    Positron emission tomography (PET) system energy response is typically characterized in singles detection mode, yet there are situations in which the energy spectrum of coincidence events might be different than the spectrum measured in singles mode. Examples include imaging with isotopes that emit a prompt gamma in coincidence with a positron emission, imaging with low activity in a LSO/LYSO-based cameras, in which the intrinsic activity is significant, and in high scatter situations where the two 511 keV photons have different scattering probabilities (i.e. off-center line source). The ability to accurately measure the energy spectrum of coincidence events could be used for validating simulation models, optimizing energy discriminator levels and examining scatter models and corrections. For many PET systems operating in coincidence mode, the only method available for estimating the energy spectrum is to step the lower and upper level discriminators (LLD and ULD). Simple measurement techniques such as using a narrow sliding energy window or stepping only the LLD will not yield a spectrum of coincidence events that is accurate for cases where there are different energy components contributing to the spectrum. In this work we propose a new method of measuring the energy spectrum of coincidence events in PET based on a linear combination of two sets of coincident count measurements: one made by stepping the LLD and one made by stepping the ULD. The method was tested using both Monte Carlo simulations of a Siemens microPET R4 camera and measured data acquired on a Siemens Inveon PET camera. The results show that our energy spectrum calculation method accurately measures the coincident energy spectra for cases including the beta/gamma spectrum of the (176)Lu intrinsic activity present in the LSO scintillator crystals, a (68)Ge source and an (124)I source (in which there are prompt gamma-rays emitted together with the positron).

  4. Analysis of femtosecond pump-probe photoelectron-photoion coincidence measurements applying Bayesian probability theory

    Science.gov (United States)

    Rumetshofer, M.; Heim, P.; Thaler, B.; Ernst, W. E.; Koch, M.; von der Linden, W.

    2018-06-01

    Ultrafast dynamical processes in photoexcited molecules can be observed with pump-probe measurements, in which information about the dynamics is obtained from the transient signal associated with the excited state. Background signals provoked by pump and/or probe pulses alone often obscure these excited-state signals. Simple subtraction of pump-only and/or probe-only measurements from the pump-probe measurement, as commonly applied, results in a degradation of the signal-to-noise ratio and, in the case of coincidence detection, the danger of overrated background subtraction. Coincidence measurements additionally suffer from false coincidences, requiring long data-acquisition times to keep erroneous signals at an acceptable level. Here we present a probabilistic approach based on Bayesian probability theory that overcomes these problems. For a pump-probe experiment with photoelectron-photoion coincidence detection, we reconstruct the interesting excited-state spectrum from pump-probe and pump-only measurements. This approach allows us to treat background and false coincidences consistently and on the same footing. We demonstrate that the Bayesian formalism has the following advantages over simple signal subtraction: (i) the signal-to-noise ratio is significantly increased, (ii) the pump-only contribution is not overestimated, (iii) false coincidences are excluded, (iv) prior knowledge, such as positivity, is consistently incorporated, (v) confidence intervals are provided for the reconstructed spectrum, and (vi) it is applicable to any experimental situation and noise statistics. Most importantly, by accounting for false coincidences, the Bayesian approach allows us to run experiments at higher ionization rates, resulting in a significant reduction of data acquisition times. The probabilistic approach is thoroughly scrutinized by challenging mock data. The application to pump-probe coincidence measurements on acetone molecules enables quantitative interpretations

  5. Memory Effects Study of Measuring Radioactive Xenon Isotopes With β-γ Coincidence Method

    International Nuclear Information System (INIS)

    Jia Huaimao; Wang Shilian; Wang Jun; Li Qi; Zhao Yungang; Fan Yuanqing; Zhang Xinjun

    2010-01-01

    The β-γ coincidence technique is a kind of the key important method to detect radioactive xenon isotopes for the Comprehensive Nuclear-Test-Ban Treaty (CTBT). This paper describes noble gases memory effects of β-γ coincidence detector. Xenon memory effects were measured and its influence on detector's minimum detectable activity (MDA) was evaluated. The methods of reducing xenon memory effects were studied. In conclusion, aluminium coated plastic scintillator and YAP scintillator can remarkably decrease xenon memory effects. (authors)

  6. Measurement of thyrotropin receptor antibodies (TRAK) with a second generation assay in patients with Graves' disease; Die Bestimmung von Thyreotropin-Rezeptor-Antikoerpern (TRAK) mit einem Assay der zweiten Generation bei Patienten mit Morbus Basedow

    Energy Technology Data Exchange (ETDEWEB)

    Zoephel, K.; Wunderlich, G.; Franke, W.G. [Klinik und Poliklinik fuer Nuklearmedizin, Technische Univ. Dresden (Germany); Koch, R. [Inst. fuer Medizinische Informatik und Biometrie, Technische Univ. Dresden (Germany)

    2000-06-01

    Aim: The detection of TSH-receptor-antibodies (TRAb) in patients (pts) with Graves' disease (GD) is routinely used in nuclear medicine laboratories. It is performed by commercial, porcine radioreceptorassays (RRA) measuring TSH binding inhibitory activity. A second generation assay using the human, recombinant TSH-receptor was developed during the last years. The manufacturer composed this new assay as a coated tube RRA (CT RRA) and claimed a higher sensitivity for GD. Methods: TRAb was measured in 207 pts with various thyroid disorders and 205 healthy controls using the new coated tube RRA (Fa. B.R.A.H.M.S. Diagnostica GmbH, Berlin, Germany) as well as a conventional RRA (Fa. Medipan Diagnostica GmbH, Selchow, Germany): 60 pts suffering from GD showing a relapse after anti-thyroid drug treatment and before radioiodine therapy, 109 pts with disseminated autonomia (DA) and 38 pts suffering from Hashimoto's thyroiditis. A ROC-analysis was performed to find the optimal decision threshold level for positivity. Results: We found 42/60 TRAb-positive pts with GD in the established RRA (threshold 6 U/L) and 52/60 in the CT RRA, respectively. The sensitivity increased from 70% (RRA) to 86,7% (CT RRA). The CT RRA found 2 false positives (one Hashimoto's and one healthy control) and the RRA detected 3 Hashimoto's and 2 healthy controls as false positive. Conclusion: The increased sensitivity of CT RRA for GD provides an advantage compared to conventional RRA, especially in GD-patients relapsing afte antithyroid drug treatment. Functional sensitivity and Interassayvariation of CT RRA are very precisely compared to conventional RRA. Handling of the new assay is also improved. (orig.) [German] Ziel: Die Bestimmung der TSH-Rezeptorantikoerper (TRAK) bei Patienten mit Morbus Basedow ist fester Bestandteil der nuklearmedizinischen In-vitro-Diagnostik. Seit kurzem ist die Bestimmung mit einem TRAK-Assay moeglich, bei dem im Gegensatz zu den herkoemmlichen

  7. Mass measurement of 80Y by β-γ coincidence spectroscopy

    International Nuclear Information System (INIS)

    Barton, C.J.; Caprio, M.A.; Beausang, C.W.; Casten, R.F.; Cooper, J.R.; Kruecken, R.; Novak, J.R.; Pietralla, N.; Brenner, D.S.; Zamfir, N.V.; Aprahamian, A.; Wiescher, M.C.; Shawcross, M.; Teymurazyan, A.; Berant, Z.; Wolf, A.; Gill, R.L.

    2003-01-01

    The Q EC value of 80 Y has been measured by β-γ coincidence spectroscopy to be ≥8929(83) keV. Combining this result with the adopted mass excess of the daughter 80 Sr gives a mass excess for 80 Y of ≥-61 376(83) keV. Results are compared with other measurements, with Audi-Wapstra systematics, and with predictions of mass formulas. Implications of this measurement are considered for the rp process

  8. Assessment of technical-scale dewatering results in decanters on the basis of measurements of water types in sewage sludge; Bestimmung grosstechnischer Entwaesserungsergebnisse in Dekantern basierend auf der Messung der Wasserarten von Klaerschlaemmen

    Energy Technology Data Exchange (ETDEWEB)

    Kopp, J.; Dichtl, N. [Technische Univ. Braunschweig (Germany). Inst. fuer Siedlungswasserwirtschaft

    1999-07-01

    In a sewage sludge suspension, three water portions can be measured and distinguished from each other. The free water portion is not bound to sludge particles and can be separated by mechanical dewatering. The interstitial water portion bound by capillary forces and bound water (on surfaces and in cells) remain in the sludge cake after dewatering. The described measuring system for thermo-gravimetric determination of the water portions of sewage sludge was adjusted and calibrated at Braunschweig Technical University and permits prognosticating the maximum attainable content of solids through mechanical dewatering in high-performance decanters. (orig.) [German] In einer Klaerschlammsuspension koennen drei Wasseranteile messtechnisch unterschieden werden. Der freie Wasseranteil ist nicht an die Schlammpartikel gebunden und ist bei einer maschinellen Entwaesserung abtrennbar. Der kapillar gehaltene Zwischenraumwasseranteil und das gebundene Wasser (auf Oberflaechen und in Zellen) verbleibt nach der Entwaesserung im Schlammkuchen. Die an der TU Braunschweig angepasste und kalibrierte Messanlage zur thermo-gravimetrischen Bestimmung der Wasseranteile eines Klaerschlammes ermoeglicht es, den maximal bei der maschinellen Entwaesserung in Hochleistungsdekantern erreichbaren Feststoffgehalt zu prognostizieren. (orig.)

  9. Evaluation of in-plant neutron coincidence counters for the measurement of molten salt extraction residues

    International Nuclear Information System (INIS)

    Langner, D.G.; Russo, P.A.; Wachter, J.R.

    1993-01-01

    Americium is extracted from plutonium by a molten salt extraction (MSE) process. The residual americium-laden salts are a significant waste stream in this pyrochemical purification process. Rapid assay of MSE residues is desirable to minimize the exposure of personnel to these often high-level emissions. However, the quantitative assay of plutonium in MSE residues is difficult. Variable, unknown (a,n) rates and variable emitted-neutron energy spectra preclude the use of standard neutron coincidence counting techniques with old-generation neutron coincidence counters. Gamma-ray assay methods have not been successful with some residues because of random lumps of plutonium metal. In this paper, we present measurements of MSE residues with two state-of-the-art neutron coincidence counters at the Los Alamos Plutonium Processing Facility: an in-line counter built for the assay of bulk waste material and the pyrochemical multiplicity counter that underwent test and evaluation at that facility. Both of these counters were designed to minimize the effects on measurements of variations in the sample geometry and variable energy spectra of emitted neutrons. These results are compared to measurements made with an HLNCII and with a 20-yr-old in-line well counter. The latter two counters are not optimized in ft sense. We conclude that the newer counters provide significantly improved assay results. The pyrochemical multiplicity counter operated in the conventional coincidence mode provided the best assays overall

  10. Mid-infrared coincidence measurements on twin photons at room temperature

    DEFF Research Database (Denmark)

    Mancinelli, M.; Trenti, A.; Piccione, S.

    2017-01-01

    Quantum measurements using single-photon detectors are opening interesting new perspectives in diverse fields such as remote sensing, quantum cryptography and quantum computing. A particularly demanding class of applications relies on the simultaneous detection of correlated single photons...... pave the way to quantum measurements in the MIR by the demonstration of a room temperature coincidence measurement with non-degenerate twin photons at about 3.1 mu m. The experiment is based on the spectral translation of MIR radiation into the visible region, by means of efficient up-converter modules...

  11. Utilization of coincidence criteria in absolute length measurements by optical interferometry in vacuum and air

    International Nuclear Information System (INIS)

    Schödel, R

    2015-01-01

    Traceability of length measurements to the international system of units (SI) can be realized by using optical interferometry making use of well-known frequencies of monochromatic light sources mentioned in the Mise en Pratique for the realization of the metre. At some national metrology institutes, such as Physikalisch-Technische Bundesanstalt (PTB) in Germany, the absolute length of prismatic bodies (e.g. gauge blocks) is realized by so-called gauge-block interference comparators. At PTB, a number of such imaging phase-stepping interference comparators exist, including specialized vacuum interference comparators, each equipped with three highly stabilized laser light sources. The length of a material measure is expressed as a multiple of each wavelength. The large number of integer interference orders can be extracted by the method of exact fractions in which the coincidence of the lengths resulting from the different wavelengths is utilized as a criterion. The unambiguous extraction of the integer interference orders is an essential prerequisite for correct length measurements. This paper critically discusses coincidence criteria and their validity for three modes of absolute length measurements: 1) measurements under vacuum in which the wavelengths can be identified with the vacuum wavelengths, 2) measurements under air in which the air refractive index is obtained from environmental parameters using an empirical equation, and 3) measurements under air in which the air refractive index is obtained interferometrically by utilizing a vacuum cell placed along the measurement pathway. For case 3), which corresponds to PTB’s Kösters-Comparator for long gauge blocks, the unambiguous determination of integer interference orders related to the air refractive index could be improved by about a factor of ten when an ‘overall dispersion value,’ suggested in this paper, is used as coincidence criterion. (paper)

  12. Complete characterization of breakup of 9Be by α-α coincidence measurements

    International Nuclear Information System (INIS)

    Rafiei, R.; Luong, D.H.; Hinde, D.J.; Dasgupta, M.; Du Rietz, R.

    2011-01-01

    The breakup mechanisms for 9 Be have been studied through coincident detection of the breakup α particles at sub-barrier energies, where the probability of capture of a charged breakup fragment by the target nucleus is negligible. Combining the reconstructed reaction Q-value and the relative energy of the two coincident breakup α particles a complete picture of breakup dynamics has been obtained. The measurements reveal breakup processes which are fast enough (~ 10 -22 s) to affect fusion, called prompt breakup. It is shown that prompt breakup is triggered predominantly by the transfer of a neutron -a two-step process. The prompt breakup probabilities are shown to have an exponential dependence on the surface-to-surface separation of the interacting nuclei, but are independent of the target nuclei, ranging from 144 Sm to 209 Bi. These results provide significant input towards a complete quantal model aiming to describe the breakup of weakly bound stable and halo nuclei. (author)

  13. Standardization of Ga-68 by coincidence measurements, liquid scintillation counting and 4πγ counting.

    Science.gov (United States)

    Roteta, Miguel; Peyres, Virginia; Rodríguez Barquero, Leonor; García-Toraño, Eduardo; Arenillas, Pablo; Balpardo, Christian; Rodrígues, Darío; Llovera, Roberto

    2012-09-01

    The radionuclide (68)Ga is one of the few positron emitters that can be prepared in-house without the use of a cyclotron. It disintegrates to the ground state of (68)Zn partially by positron emission (89.1%) with a maximum energy of 1899.1 keV, and partially by electron capture (10.9%). This nuclide has been standardized in the frame of a cooperation project between the Radionuclide Metrology laboratories from CIEMAT (Spain) and CNEA (Argentina). Measurements involved several techniques: 4πβ-γ coincidences, integral gamma counting and Liquid Scintillation Counting using the triple to double coincidence ratio and the CIEMAT/NIST methods. Given the short half-life of the radionuclide assayed, a direct comparison between results from both laboratories was excluded and a comparison of experimental efficiencies of similar NaI detectors was used instead. Copyright © 2012 Elsevier Ltd. All rights reserved.

  14. Nuclear lifetime measurements with the DSA coincidence method in inverse reactions

    International Nuclear Information System (INIS)

    Hermans, J.A.J.

    1977-01-01

    This thesis describes lifetime measurements with the DSA coincidence method in inverse reactions. Bombardment of 2 H and 3 H targets with heavy ions of energies up to 50 MeV produces nuclei recoiling at initial velocities of v(0) approximately equal to 0.05 c. Heavy-ion beams of 11 B, 12 C, 14 N, 16 O, 18 O, 19 F, 27 A1, 28 Si, 30 Si, 31 P, 32 S, 35 Cl and 37 Cl are at present available from the Utrecht 6 MV EN tandem accelerator. The recoil nuclei are slowed down in Mg, Al, Cu, Ag or Au and the γ-ray Doppler pattern is observed with a large Ge(Li) detector in coincidence with protons

  15. Standardization of Ga-68 by coincidence measurements, liquid scintillation counting and 4πγ counting

    International Nuclear Information System (INIS)

    Roteta, Miguel; Peyres, Virginia; Rodríguez Barquero, Leonor; García-Toraño, Eduardo; Arenillas, Pablo; Balpardo, Christian; Rodrígues, Darío; Llovera, Roberto

    2012-01-01

    The radionuclide 68 Ga is one of the few positron emitters that can be prepared in-house without the use of a cyclotron. It disintegrates to the ground state of 68 Zn partially by positron emission (89.1%) with a maximum energy of 1899.1 keV, and partially by electron capture (10.9%). This nuclide has been standardized in the frame of a cooperation project between the Radionuclide Metrology laboratories from CIEMAT (Spain) and CNEA (Argentina). Measurements involved several techniques: 4πβ−γ coincidences, integral gamma counting and Liquid Scintillation Counting using the triple to double coincidence ratio and the CIEMAT/NIST methods. Given the short half-life of the radionuclide assayed, a direct comparison between results from both laboratories was excluded and a comparison of experimental efficiencies of similar NaI detectors was used instead. - Highlights: ► We standardized the positron emitter Ga-68 in a bilateral cooperation. ► We used several techniques, as coincidence, integral gamma and liquid scintillation. ► An efficiency comparison replaced a direct comparison of reference materials.

  16. Digital spectrometer for coincidence measurement of Doppler broadening of positron annihilation radiation

    International Nuclear Information System (INIS)

    Cizek, J.; Vlcek, M.; Prochazka, I.

    2010-01-01

    High-resolution digital coincidence Doppler broadening spectrometer equipped with two high-purity Ge detectors and two-channel 12-bit fast digitizer was developed and tested in this work. Two configurations were compared: (i) semi-digital setup which uses active analogue shaping of detector pulses prior to digitization to improve signal-to-noise ratio, and (ii) pure-digital setup which samples detector pulses directly. Software procedure developed for analysis of sampled waveforms, i.e. precise determination of energy of detected photon and rejection of distorted pulses, is described. Performance of digital coincidence spectrometer was compared with traditional analogue setup connected to the same detectors. It was found that digital spectrometer enables to achieve better energy resolution than in traditional analogue setup. Moreover, in digital configuration one has better control over shape of the signal. This allows efficient elimination of undesired distorted or damaged waveforms and to obtain spectrum of better clarity. The superior parameters of new digital coincidence Doppler broadening spectrometer are demonstrated by benchmark measurements of well defined Fe and Al specimens and also by the detection of rare annihilation in flight events.

  17. Study of the continuum in heavy ion inelastic spectra by light particle coincidence measurements

    International Nuclear Information System (INIS)

    Scarpaci, J.A.; Blumenfeld, Y.; Chomaz, P.; Frascaria, N.; Garron, J.P.; Roynette, J.C.; Suomijarvi, T.; Van der Woude, A.; Alamanos, N.; Fernandez, B.; Gillibert, A.; Van der Woude, A.; Lepine, A.

    1990-01-01

    The continuum in heavy ion inelastic spectra contains, in addition to the excitation of target nucleus states, contributions from pick-up break-up and knock out reactions. In the case of the 40 Ca + 40 Ca collision at 50 MeV/N these contributions are separated and their relative importance assessed by the measurement of light charged particles in coincidence with the inelastically scattered fragments. The pick-up break-up contribution is found to make up less than half of the cross section at high excitation energies, conversely, the knock out process is important

  18. Hypernuclear weak decay experiments at KEK: n-n and n-p coincidence measurement

    International Nuclear Information System (INIS)

    Outa, H.; Ajimura, S.; Aoki, K.; Banu, A.; Bhang, H.C.; Fukuda, T.; Hashimoto, O.; Hwang, J.I.; Kameoka, S.; Kang, B.H.; Kim, E.H.; Kim, J.H.; Kim, M.J.; Maruta, T.; Miura, Y.; Miyake, Y.; Nagae, T.; Nakamura, M.; Nakamura, S.N.; Noumi, H.; Okada, S.; Okayasu, Y.; Park, H.; Saha, P.K.; Sato, Y.; Sekimoto, M.; Takahashi, T.; Tamura, H.; Tanida, K.; Toyoda, A.; Tsukada, K.; Watanabe, T.; Yim, H.J.

    2005-01-01

    We performed a coincidence measurement of two nucleons emitted from the nonmesonic weak decay (NMWD) of 5 Λ He and 12 Λ C formed via the (π+,K+) reaction. In both of n+p and n+n pair coincidence spectra, we observed a clean back-to-back correlation coming from the two-body decay of Λp->np and Λn->nn, respectively. We obtained the ratio of the nucleon pair numbers, Nnn/Nnp ( 5 Λ He)=0.45-bar +/--bar 0.11-bar (stat)-bar +/--bar 0.03-bar (syst) in the kinematic region of cosθNN-0.8. Since each decay mode was exclusively detected, the measured ratio should be close to the ratio of Γ(Λp->nn)/Γ(Λn->np). The Γn/Γp ratio was measured also for the NMWD of 12 Λ C. It is also close to 0.5. Those ratios are consistent with recent theoretical calculations based on the heavy meson/direct quark exchange picture

  19. The underwater coincidence counter for plutonium measurements in mixed-oxide fuel assemblies manual

    International Nuclear Information System (INIS)

    Eccleston, G.W.; Menlove, H.O.; Abhold, M.; Baker, M.; Pecos, J.

    1999-01-01

    This manual describes the Underwater Coincidence Counter (UWCC) that has been designed for the measurement of plutonium in mixed-oxide (MOX) fuel assemblies prior to irradiation. The UWCC uses high-efficiency 3 He neutron detectors to measure the spontaneous-fission and induced-fission rates in the fuel assembly. Measurements can be made on MOX fuel assemblies in air or underwater. The neutron counting rate is analyzed for singles, doubles, and triples time correlations to determine the 240 Pu effective mass per unit length of the fuel assembly. The system can verify the plutonium loading per unit length to a precision of less than 1% in a measurement time of 2 to 3 minutes. System design, components, performance tests, and operational characteristics are described in this manual

  20. Monte Carlo simulation of activity measurements by means of 4πβ-γ coincidence system

    International Nuclear Information System (INIS)

    Takeda, Mauro N.; Dias, Mauro S.; Koskinas, Marina F.

    2004-01-01

    The methodology for simulating all detection processes in a 4πβ-γ coincidence system by means of the Monte Carlo technique is described. The goal is to predict the behavior of the observed activity as a function of the 4πβ detector efficiency. In this approach, the information contained in the decay scheme is used for determining the contribution of all radiations emitted by the selected radionuclide, to the measured spectra by each detector. This simulation yields the shape of the coincidence spectrum, allowing the choice of suitable gamma-ray windows for which the activity can be obtained with maximum accuracy. The simulation can predict a detailed description of the extrapolation curve, mainly in the region where the 4πβ detector efficiency approaches 100%, which is experimentally unreachable due to self absorption of low energy electrons in the radioactive source substrate. The theoretical work is being developed with MCNP Monte Carlo code, applied to a gas-flow proportional counter of 4π geometry, coupled to a pair of NaI(Tl) crystals. The calculated efficiencies are compared to experimental results. The extrapolation curve can be obtained by means of another Monte Carlo algorithm, being developed in the present work, to take into account fundamental characteristics of a complex decay scheme, including different types of radiation and transitions. The present paper shows preliminary calculated values obtained by the simulation and compared to predicted analytical values for a simple decay scheme. (author)

  1. Aspects of kinematical coincidence measurements of excitation energy division in damped reactions

    International Nuclear Information System (INIS)

    Toke, J.; Schroeder, W.U.; Huizenga, J.R.; Rochester Univ., NY

    1990-01-01

    It is shown that the finite resolution inherent in the kinematical coincidence method leads to systematic errors in the deduced (primary) physical quantities if the latter are calculated based on mass and linear momentum conservation equations alone. As an example, application of this method for measuring excitation energy of the fragments from damped reactions is reviewed. In such a case, finite resolution effects generate significant instrumental, or 'background' correlations between the physical quantities reconstructed in a straightforward fashion, hence, if not accounted for, they may lead to the qualitative misinterpretation of the data. Experimental measures are discussed which appear necessary in order to ensure proper accuracy of the finite resolution corrections. An alternative method of data analysis is presented which is much less susceptible to the finite resolution effects discussed. (orig.)

  2. High mass-resolution electron-ion-ion coincidence measurements on core-excited organic molecules

    CERN Document Server

    Tokushima, T; Senba, Y; Yoshida, H; Hiraya, A

    2001-01-01

    Total electron-ion-ion coincidence measurements on core excited organic molecules have been carried out with high mass resolution by using multimode (reflectron/linear) time-of-flight mass analyzer. From the ion correlation spectra of core excited CH sub 3 OH and CD sub 3 OH, the reaction pathway to form H sub 3 sup + (D sub 3 sup +) is identified as the elimination of three H (D) atoms from the methyl group, not as the inter-group (-CH sub 3 and -OH) interactions. In a PEPIPICO spectrum of acetylacetone (CH sub 3 COCH sub 2 COCH sub 3) measured by using a reflectron TOF, correlations between ions up to mass number 70 with one-mass resolution was recorded.

  3. Measuring 226Ra and 232Th activity in soil and vegetation samples using a method of double γ-coincidences

    International Nuclear Information System (INIS)

    Antovic, N.M.; Antovic, I.

    2010-01-01

    A coincidence method for measuring radium and thorium activity has been developed using the PRIPYAT-2M gamma-ray coincidence spectrometer, with six NaI(Tl) detectors and registration geometry close to 4π. It was tested by measuring soil samples from the Northern region of Montenegro, as well as vegetation samples from the same region. The results showed a good agreement with ones obtained by the HPGe spectrometer. (author)

  4. Positron emission measurement with coincidence counting technic using large plastic scintillators

    International Nuclear Information System (INIS)

    Espinasse, P.; Minchella, P.

    1990-01-01

    For measuring positron emission of a large organ such as the brain for example, a device has been built with two cylindric plastic scintillators allowing the detection in coincidence of the 511 keV gamma rays without any spectrometry. The main results are for the sensitivity at the center of the field with 22 Na source in water: 240 ips/MBq; background = 12 ips, and for the countloss due to the deadtime >5% with 42 MBq. Sensitivity is almost uniform on the main axis between the probes. It falls to about 50% on the edges of a central diameter of 20 cm. The performances could certainly be improved by using modern rapid photomultipliers [fr

  5. Upgrading DRACULA setup to be used for light products - fission fragments coincidence measurements

    International Nuclear Information System (INIS)

    Simion, V.; Petrovici, M.; Pop, A.; Berceanu, I.; Duma, M.; Moisa, D.; Pagano, A.; Geraci, E.

    1999-01-01

    At low bombarding energy (E/A 238 U give rise to a number of fission processes, all leading to very similar fission products. Therefore, in order to understand the fission processes in this energy domain it is of interest to determine the amount of fission occurring after a peripheral interaction relative to that originating from compound nucleus formation. Although the detection of a projectile residue (PLF) in coincidence with the fission fragments is a very promising probe for the macroscopic features of the mechanism of induced fission, at incident energies in the vicinity of the Coulomb barrier (E/A 2 cross section area uses the phoswich technique by coupling a thin fast NE102A plastic scintillator to a 10 cm long BaF 2 crystal of hexagonal section. The BaF 2 crystal detectors have been successfully used in modular multielement detector ARGOS in the context of GANCT and HOTCT researches at LNS. The light response of the phoswich configuration as a function of the plastic thickness and of the energy and charge of the incident ion has been studied at Tandem energies. Both arrays will be placed in separate vacuum chambers attached to the remaining large angular opening windows of the reaction chamber. By rotating the whole device the fission fragment detection arrays will cover a range of 96 angle in the horizontal plane. The main advantage of this setup is that it allows to perform continuous measurements in energy and angle of the reaction products. The geometry of the whole device has been tested by Monte Carlo calculations using the code ELPHIC. The coincidence condition is completely fulfilled for the first two positions of the setup and partially for the third one. Measurements are intended to be performed at the SMP Tandem from LNS-Catania using light beams ( 16 O, 19 F, 20 Ne, 32 S) at ∼ 6 MeV/A on high fissility parameter targets. (authors)

  6. The spallation in reverse kinematics: what for a coincidence measurement?; La spallation en cinematique inverse: pourquoi faire une mesure en coincidence?

    Energy Technology Data Exchange (ETDEWEB)

    Ducret, J.E

    2006-07-15

    The Spaladin installation has been designed to study spallation reactions in reverse kinematics. Furthermore, the heavy and light fragments are detected by coincidence which allows us to get an instantaneous picture of the reaction at a level of accuracy better than that obtained through inclusive measurement. The first part is dedicated to the theoretical description of the different mechanisms involved in the spallation reactions. In the second part we describe the Spaladin installation and report some results on the reaction: Fe{sup 56} + p at an energy of 1 GeV/nucleon. In the third part we expose the performance of the installation through its simulation with the Geant-IV model. We present a study about the sensitivity of the Spaladin installation to theoretical predictions. The fourth part is dedicated to the future experiments that will be performed with the Spaladin installation. (A.C.)

  7. Accurate measurements of E2 lifetimes using the coincidence recoil-distance method

    Science.gov (United States)

    Bhalla, R. K.; Poletti, A. R.

    1984-05-01

    Mean lives of four E2 transitions in the (2s, 1d) shell have been measured using the recoil-distance method (RDM), γ-rays de-exciting the level of interest were detected in coincidence with particles detected in an annular detector at a backward angle thereby reducing the background and producing a beam of recoiling nuclei of well-defined energy and recoil direction. Lifetimes measured were: 22Ne, 1.275 MeV level (2 + → 0 +), 5.16±0.13 ps; 26Mg, 3.588 MeV level (0 + → 2 +), 9.29±0.23 ps; 30Si, 3.788 MeV level (0 +→ 2 +), 12.00±0.70 ps; 38Ar, 3.377 MeV level (0 + → 2 +), 34.5±1.5 ps. The present measurements are compared to those of previous investigators. For the 22Ne level, averaged results from four different measurement techniques are compared and found to be in good agreement. The experimental results are compared to shell-model calculations.

  8. Accurate measurements of E2 lifetimes using the coincidence recoil-distance method

    International Nuclear Information System (INIS)

    Bhalla, R.K.; Poletti, A.R.

    1984-01-01

    Mean lives of four E2 transitions in the (2s, 1d) shell have been measured using the recoil-distance method (RDM). γ-rays de-exciting the level of interest were detected in coincidence with particles detected in an annular detector at a backward angle thereby reducing the background and producing a beam of recoiling nuclei of well-defined energy and recoil direction. Lifetimes measured were: 22 Ne, 1.275 MeV level (2 + -> 0 + ), 5.16 +- 0.13 ps; 26 Mg, 3.588 MeV level (0 + -> 2 + ), 9.29 +- 0.23 ps; 30 Si, 3.788 MeV level (0 + -> 2 + ), 12.00 +- 0.70 ps; 38 Ar, 3.377 MeV level (0 + -> 2 + ), 34.5 +- 1.5 ps. The present measurements are compared to those of previous investigators. For the 22 Ne level, averaged results from four different measurement techniques are compared and found to be in good agreement. The experimental results are compared to shell-model calculations. (orig.)

  9. First satellite measurements of chemical changes in coincidence with sprite activity

    Science.gov (United States)

    Arnone, Enrico; São Sabbas, Fernanda; Kero, Antti; Soula, Serge; Carlotti, Massimo; Chanrion, Olivier; Dinelli, Bianca Maria; Papandrea, Enzo; Castelli, Elisa; Neubert, Torsten

    2010-05-01

    The last twenty years have seen the discovery of electric discharges in the Earth's atmosphere above thunderstorms, the so-called sprites and jets. It has been suggested that they impact the atmospheric chemistry and possibly affect the ozone layer through their repeated occurrence. Whereas theoretical studies and laboratory experiments suggest enhancement of such gasses as nitrogen oxides by up to hundreds of percent within sprites, a definitive detection of their chemical effects have to date been unsuccessful. In this paper, we report on the first measurements of atmospheric chemical perturbations recorded in coincidence with sprite activity. A striking event occurred on 25 August 2003 when the MIPAS spectrometer onboard the Envisat satellite recorded spectroscopic measurements soon after a sequence of 11 sprites observed above Corsica (France) by Eurosprite ground facilities (details of the convective system are discussed in a companion paper by São Sabbas et al.). The measurements show an enhancement of ambient nitrous oxide by 80% at 52 km altitude in the region above the parent thunderstorm. The recorded chemical changes imply sprites can exert significant modification of the atmospheric chemistry at a regional scale, confirming model and laboratory predictions of sprite-chemistry, and requiring a new estimate of their global impact. The results of the analysis and their implications are discussed.

  10. The measurement of cross sections of inelastic and transfer reactions with gamma-particle coincidence

    Energy Technology Data Exchange (ETDEWEB)

    Zagatto, V.A.B.; Oliveira, J.R.B.; Pereira, D.; Allegro, P.R.P.; Chamon, L.C.; Cybulska, E.W.; Medina, N.H.; Ribas, R.V.; Rossi Junior, E.S.; Seale, W.A.; Silva, C.P.; Gasques, L. [Universidade de Sao Paulo (IF/USP), SP (Brazil). Inst. de Fisica; Toufen, D.L. [Instituto Federal de Educacao, Ciencia e Tecnologia, Guarulhos, SP (Brazil); Silveira, M.A.G. [Centro Universitario da FEI, Sao Bernardo do Campo, SP (Brazil); Zahn, G.S.; Genezini, F.A.; Shorto, J.M.B. [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil); Lubian, J.; Linares, R. [Universidade Federal Fluminense (UFF), Niteroi, RJ (Brazil). Inst. de Fisica; Nobre, G.P. [Lawrence Livermore National Laboratory, Livermore (United States)

    2012-07-01

    Full text: A new method was developed in Pelletron laboratory to measure gamma-particle coincidences and the chosen experiment to test this method was the {sup 18}O +{sup 110} Pd in the 46-60 MeV range. The following work aims to obtain experimental cross sections of inelastic excitation 0{sup +} {yields} 2{sup +} of {sup 110}Pd and transfer to excited states reactions (both measured by gamma-particle coincidences). The measurements were made at the Pelletron accelerator laboratory of the University of Sao Paulo with the Saci-Perere spectrometer [1], which consists of 4 GeHP Compton suppressed gamma detectors and a 4{pi} charged particle ancillary system with 11{Delta}E-E plastic phoswich scintillators (further details about the experimental procedure may be found in [2]). Calculations were performed with a new model based on the Sao Paulo Potential, specifically developed for the inclusion of dissipative processes like deep-inelastic collisions (DIC) [3,4] considering the Coulomb plus nuclear potential (with the aid of FRESCO code [5]). The experimental cross sections were obtained such as described in [6] including particle-gamma angular correlations, finite size of gamma and particle detectors as the vacuum de-alignment effects [7] (caused by hyperfine interaction) for the {sup 110}Pd inelastic reaction and for the {sup 110}Pd 2n transfer reaction. Also the effects of the beam spot size and energy loss in the target were included in these calculations. For these purposes a new code has been developed to assist in the data analysis. The gamma-particle angular correlations are calculated using the scattering amplitudes given by FRESCO. The theoretical predictions still consider 2 different types of normalization factors in its the real part: 1:0, and 0:6 as proposed in [3] for the weakly bound projectile cases. The analyses indicate that the 0:6 factor describes better the experimental data possible due to the large density of states in the transitional region. [1

  11. Instrument limitation of accuracy of absolute measurement by method of 4π beta-gamma coincidence

    International Nuclear Information System (INIS)

    Plkh, J.

    1979-01-01

    Accuracy is discussed of determination of coincidence channels dead-time in 4π β-γ installation and determination of coincidence resolution time as well as conditions for determination and accuracy of these parameters. Conditions are considered under which these parameters have not been determined and there is wrong performance of the installation. Special attention was paid to the electronic circuit of the γ-channel. It has been shown that as a result of wrong performance of electronic circuit a new type of wrong coincidence appeared [ru

  12. Low level radioactivity measurements with phoswich detectors using coincident techniques and digital pulse processing analysis.

    Science.gov (United States)

    de la Fuente, R; de Celis, B; del Canto, V; Lumbreras, J M; de Celis Alonso, B; Martín-Martín, A; Gutierrez-Villanueva, J L

    2008-10-01

    A new system has been developed for the detection of low radioactivity levels of fission products and actinides using coincidence techniques. The device combines a phoswich detector for alpha/beta/gamma-ray recognition with a fast digital card for electronic pulse analysis. The phoswich can be used in a coincident mode by identifying the composed signal produced by the simultaneous detection of alpha/beta particles and X-rays/gamma particles. The technique of coincidences with phoswich detectors was proposed recently to verify the Nuclear Test Ban Treaty (NTBT) which established the necessity of monitoring low levels of gaseous fission products produced by underground nuclear explosions. With the device proposed here it is possible to identify the coincidence events and determine the energy and type of coincident particles. The sensitivity of the system has been improved by employing liquid scintillators and a high resolution low energy germanium detector. In this case it is possible to identify simultaneously by alpha/gamma coincidence transuranic nuclides present in environmental samples without necessity of performing radiochemical separation. The minimum detectable activity was estimated to be 0.01 Bq kg(-1) for 0.1 kg of soil and 1000 min counting.

  13. Low level radioactivity measurements with phoswich detectors using coincident techniques and digital pulse processing analysis

    International Nuclear Information System (INIS)

    Fuente, R. de la; Celis, B. de; Canto, V. del; Lumbreras, J.M.; Celis, Alonso B. de; Martin-Martin, A.; Gutierrez-Villanueva, J.L.

    2008-01-01

    A new system has been developed for the detection of low radioactivity levels of fission products and actinides using coincidence techniques. The device combines a phoswich detector for α/β/γ-ray recognition with a fast digital card for electronic pulse analysis. The phoswich can be used in a coincident mode by identifying the composed signal produced by the simultaneous detection of α/β particles and X-rays/γ particles. The technique of coincidences with phoswich detectors was proposed recently to verify the Nuclear Test Ban Treaty (NTBT) which established the necessity of monitoring low levels of gaseous fission products produced by underground nuclear explosions. With the device proposed here it is possible to identify the coincidence events and determine the energy and type of coincident particles. The sensitivity of the system has been improved by employing liquid scintillators and a high resolution low energy germanium detector. In this case it is possible to identify simultaneously by α/γ coincidence transuranic nuclides present in environmental samples without necessity of performing radiochemical separation. The minimum detectable activity was estimated to be 0.01 Bq kg -1 for 0.1 kg of soil and 1000 min counting

  14. Single track coincidence measurements of fluorescent and plastic nuclear track detectors in therapeutic carbon beams

    International Nuclear Information System (INIS)

    Osinga, J-M; Jäkel, O; Ambrožová, I; Brabcová, K Pachnerová; Davídková, M; Akselrod, M S; Greilich, S

    2014-01-01

    In this paper we present a method for single track coincidence measurements using two different track detector materials. We employed plastic and fluorescent nuclear track detectors (PNTDs and FNTDs) in the entrance channel of a monoenergetic carbon ion beam covering the therapeutic energy range from 80 to 425 MeV/u. About 99% of all primary particle tracks detected by both detectors were successfully matched, while 1% of the particles were only detected by the FNTDs because of their superior spatial resolution. We conclude that both PNTDs and FNTDs are suitable for clinical carbon beam dosimetry with a detection efficiency of at least 98.82% and 99.83% respectively, if irradiations are performed with low fluence in the entrance channel of the ion beam. The investigated method can be adapted to other nuclear track detectors and offers the possibility to characterize new track detector materials against well-known detectors. Further, by combining two detectors with a restricted working range in the presented way a hybrid-detector system can be created with an extended and optimized working range

  15. A gamma-gamma coincidence/anticoincidence spectrometer for low-level cosmogenic (22)Na/(7)Be activity ratio measurement.

    Science.gov (United States)

    Zhang, Weihua; Ungar, Kurt; Stukel, Matthew; Mekarski, Pawel

    2014-04-01

    In this study, a digital gamma-gamma coincidence/anticoincidence spectrometer was developed and examined for low-level cosmogenic (22)Na and (7)Be in air-filter sample monitoring. The spectrometer consists of two bismuth germanate scintillators (BGO) and an XIA LLC Digital Gamma Finder (DGF)/Pixie-4 software and card package. The spectrometer design allows a more selective measurement of (22)Na with a significant background reduction by gamma-gamma coincidence events processing. Hence, the system provides a more sensitive way to quantify trace amounts of (22)Na than normal high resolution gamma spectrometry providing a critical limit of 3 mBq within a 20 h count. The use of a list-mode data acquisition technique enabled simultaneous determination of (22)Na and (7)Be activity concentrations using a single measurement by coincidence and anticoincidence mode respectively. Copyright © 2014 Elsevier Ltd. All rights reserved.

  16. Coincidence measurements in α/β/γ spectrometry with phoswich detectors using digital pulse shape discrimination analysis

    International Nuclear Information System (INIS)

    Celis, B. de; Fuente, R. de la; Williart, A.; Celis Alonso, B. de

    2007-01-01

    A novel system has been developed for the detection of low radioactivity levels using coincidence techniques. The device combines a phoswich detector for α/β/γ ray recognition with a fast digital card for electronic pulse analysis. The detector is able to discriminate different types of radiation in a mixed α/β/γ field and can be used in a coincidence mode by identifying the composite signal produced by the simultaneous detection of β particles in a plastic scintillator and γ rays in an NaI(Tl) scintillator. Use of a coincidence technique with phoswich detectors was proposed recently to verify the Nuclear Test Ban Treaty, which made it necessary to monitor the low levels of xenon radioisotopes produced by underground nuclear explosions. Previous studies have shown that combining CaF 2 (Eu) for β ray detection and NaI(Tl) for γ ray detection makes it difficult to identify the coincidence signals because of the similar fluorescence decay times of the two scintillators. With the device proposed here, it is possible to identify the coincidence events owing to the short fluorescence decay time of the plastic scintillator. The sensitivity of the detector may be improved by employing liquid scintillators, which allow low radioactivity levels from actinides to be measured when present in environmental samples. The device developed is simpler to use than conventional coincidence equipment because it uses a single detector and electronic circuit, and it offers fast and precise analysis of the coincidence signals by employing digital pulse shape analysis

  17. Coincidence measurements with the use of detectors measuring the energy of the radiances (proportional meters and scintillation counter); Mesures de coincidences avec utilisation de detecteurs mesurant l'energie des rayonnements (compteurs proportionnels et compteur a scintillations)

    Energy Technology Data Exchange (ETDEWEB)

    Sartory, M [Commissariat a l' Energie Atomique, Saclay(France). Centre d' Etudes Nucleaires

    1953-07-01

    In the setting of the realization of a set of installations permitting of the measures of coincidences between sorted radiances according to their energies, an installation understanding a proportional counter and a scintillation counter has been constructed and optimized. It has been used to do some measures of coincidences between X{sub K} photons and photons {gamma} issued at the time of the radioactive transformation of the selenium 75 (electronic capture). The efficiency of the proportional meter has been determined roughly. Besides, a proportional counter of solid angle neighboring of 4{pi} was able to achieve measures of coincidences while only doing one selection of amplitudes: indeed, the simultaneity of the detection of two radiances appear by an impulse whose amplitude is the sum of the amplitudes of the impulses resulting from each of the studied radiations. This method, applied to the coincidences between X-rays, permitted to bring the information on the diagram of decay of the arsenic 73. Besides, the coefficient of internal conversion of a consecutive transition to this decay has been valued. (author) [French] Dans le cadre de la realisation d'une serie de montages permettant des mesures de coincidences entre rayonnements tries d'apres leurs energies, un montage comprenant un compteur proportionnel et un compteur a scintillations a ete construit et mis au point. Il a ete utilise pour effectuer quelques mesures de coincidences entre photons X{sub K} et photons {gamma} emis lors de la transformation radioactive du selenium 75 (capture electronique). L'efficacite du compteur proportionnel a ete approximativement determinee. De plus, un compteur proportionnel d'angle solide voisin de 4{pi} a pu etre utilise pour realiser des mesures de coincidences en n'effectuant qu'une selection d'amplitudes: en effet, la simultaneite de la detection de deux rayonnements se manifeste par une impulsion dont l'amplitude est la somme des amplitudes des impulsions

  18. Measurement of chloride and sulfate in residues from municipal solid waste incineration; Bestimmung von Chlorid und Sulfat in Reststoffen aus der thermischen Abfallbehandlung

    Energy Technology Data Exchange (ETDEWEB)

    Simon, F.G. [ABB Forschungszentrum, Abt. Umwelttechnologien, Baden-Daettwil (Switzerland); Birkenberger, R. [ABB Forschungszentrum, Abt. Umwelttechnologien, Baden-Daettwil (Switzerland); Schmidt, V. [ABB Forschungszentrum, Abt. Umwelttechnologien, Baden-Daettwil (Switzerland); Levina, M. [ABB Forschungszentrum, Abt. Umwelttechnologien, Baden-Daettwil (Switzerland)

    1996-03-01

    The concentrations of the chloride and sulfate in waste incineration ashes and leachate of these solids have been measured with ionselective electrodes and the ion chromotography. The results are compared with the legislative requirements. (orig.) [Deutsch] Die Konzentrationen der Anionen Chlorid und Sulfat in Abfallverbrennungsaschen sowie in Eluaten dieser Stoffe wurden mit ionenselektiven Elektroden und der Ionenchromotographie gemessen. Die Resultate werden mit den gesetzlichen Anforderungen verglichen. (orig.)

  19. Measurement of the masses of the electroweak gauge bosons at L3; Bestimmung der Massen der elektroschwachen Eichbosonen bei L3

    Energy Technology Data Exchange (ETDEWEB)

    Rosenbleck, C.

    2006-10-09

    This thesis presents the measurement of the masses of the carriers of the weak force in the Standard Model of Particle Physics, the gauge bosons W and Z. The masses are determined using the kinematics of the bosons' decay products. The data were collected by the L3 experiment at the Large Electron Positron Collider (LEP) at centre-of-mass energies, {radical}(s), between 183 GeV and 209 GeV in the years 1997 to 2000. The Z-boson mass is determined to be m{sub Z}=91.272{+-}0.046 GeV. The second part of this analysis describes the measurement of the mass of the W-boson. The W-boson mass is determined to be m{sub W}=80.242{+-}0.057 GeV in this analysis. If combined with the L3 results at lower centre-of-mass energies, the final W boson mass value is m{sub W}=80.270{+-}0.055 GeV. The {rho} parameter is defined as {rho}=m{sup 2}{sub W}/(m{sup 2}{sub Z} . cos{sup 2} {theta}{sub W}). Using the value of m{sub Z} obtained in the Z resonance scan, the final value for m{sub W} and the value of {theta}{sub W}, {rho} is obtained to be {rho}=0.9937{+-}0.0024, yielding a 2.6{sigma} deviation from 1. Combining the L3 value for m{sub W} with the results of the LEP experiments ALEPH, DELPHI, and OPAL and the TEVATRON experiments CDF and DOe yields a W boson mass of m{sub W}=80.392{+-}0.029 GeV. Together with other measurements this determines the best value of the Higgs-boson mass to be m{sub H}=85{sub -28}{sup +39} GeV. (orig.)

  20. Thermografic measurement of crack initiation and propagation at thin sheet joints; Rissentstehung thermometrisch ermitteln. Zerstoerungsfreie Bestimmung der Rissinitiierung in mechanisch gefuegten und widerstandpunktgeschweissten Verbindungen

    Energy Technology Data Exchange (ETDEWEB)

    Bathke, W.; Stahlfeld, G. [Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin (Germany). Fachgruppe V.5 - Sicherheit in der Fuegetechnik

    2000-07-01

    This contribution demonstrates how a thermometric procedure might be applied to determine crack initiation during fatigue testing of joints at steel sheets. The procedure is based on the measurement of the temperature increase which is produced by the heat at the respective joint caused by deformation energy. Such investigations are aimed at detection of crack initiation before it becomes visible at the specimen surface. Thermografic measurements at different mechanical joints and resistance welded spots are compared and various applications are suggested. (orig.) [German] In diesem Beitrag wird gezeigt, wie sich ein thermometrisches Verfahren einsetzen laesst, um die Rissentstehung waehrend der Dauerschwingpruefung von Stahlblechen zu erfassen. Vergleichend werden Messungen an Proben, die durch Stanznieten, Clinchen und Widerstandspunktschweissen gefuegt wurden, gegenuebergestellt. Hierzu wird die am Fuegepunkt waehrend der Pruefung in Waerme umgewandelte Formaenderungsenergie kontinuierlich in Form der Temperaturerhoehung gemessen. Ziel dieser Untersuchungen ist es, solche Temperaturerhoehungen zur Erkennung der Rissentstehung zu verwenden, bevor der Riss die Blechoberflaeche erreicht hat und visuell erkennbar wird. Zudem werden verschiedene Anwendungsmoeglichkeiten vorgeschlagen. (orig.)

  1. Measurements of diffuse emissions of halogenated hydrocarbons by high resolution FTIR remote sensing. Fernerkundungsmessungen zur interferometrischen Bestimmung der Emission halogenierter Kohlenwasserstoffe im Infraroten; Schlussbericht

    Energy Technology Data Exchange (ETDEWEB)

    Bittner, H; Eisenmann, T

    1993-07-01

    Fenceline and perimeter monitoring of toxic volatile organic compounds in industrial areas is an important upcoming need for surveillance purposes. It demands for multicomponent analysis methods. These requirements will be fullfilled using the double pendulum interferometer together with the appropriate evaluation software, especially for mobile outdoor applications. The instrument based on the patented double pendulum principle has been developed within the frame of the project to the level of a pre-production model. With the developed instrument and software, measurement campaigns have been carried out at various facilities: At a fuel dump, at a chemical production, and at metal degreasing facilities. The following gases have been detected down to very low concentrations (low ppb levels): dichloromethane, trichloroethylene, tetrachloroethylene, benzene, toluene, methanol, ethyl acetate, alkenes, total hydrocarbons. The developed instrumentation as well as the results from various campaigns will be presented together with the data evaluation technique. The analytical methods and the possible sources of error will also be discussed. (orig.)

  2. Coincidence measurements of the (π+,π0p) reaction in the /triangle/-resonance region

    International Nuclear Information System (INIS)

    Hoeibraten, S.

    1989-05-01

    This thesis describes an experimental study of the (π + , π 0 p) reaction at incident energy T/sub π/sup +// = 165 MeV. This work is part of the first experiment to detect neutral pions and protons in coincidence in kinematically complete measurements. The reaction was studied on 16 O (using water targets) at several pion angles: θ/sub π/sup 0// = 70/degree/, 80/degree/, 110/degree/, and 130/degree/. At θ/sub π/sup 0// = 110/degree/ measurements were also made on 56 Fe, 120 Sn, and 208 Pb. The neutral pions were detected with the LAMPF π 0 spectrometer, while the protons were detected in a vertical array of plastic-scintillator ΔE-E telescopes, each spanning 8.5 msr. Energy spectra of the differential cross sections d 4 σ/dE/sub π/sup 0// dE/sub p/dΩ/sub π/sup 0//dΩ/sub p/ were obtained for each proton telescope and subsequently integrated over proton and pion energy and proton angle. The characteristics of these spectra are consistent with a quasi-free description of the (π + ,π 0 p) reaction. The angular dependence of dσ/dΩ/sub π/sup 0//(θ/sub π/sup 0//) for 16 O(π + ,π 0 p) was found to be in accordance with that of the cross section for the corresponding free reaction at backward π 0 angles. For the 16 O(π + ,π 0 p) reaction, events in which a p-shell nucleon had been removed were identified. The p-shell events were found to constitute only 40--50% of the total cross section for quasi-free one-nucleon removal. The (π + ,π 0 p) cross section at θ/sub π/sup 0// = 110/degree/ proved to be almost the same for all target nuclei, possibly slightly decreasing as a function of A. 102 refs., 108 figs., 24 tabs

  3. The measurement of cross sections of inelastic and transfer reactions with gamma-particle coincidence

    International Nuclear Information System (INIS)

    Zagatto, V.A.B.; Oliveira, J.R.B.; Pereira, D.; Allegro, P.R.P.; Chamon, L.C.; Cybulska, E.W.; Medina, N.H.; Ribas, R.V.; Rossi Junior, E.S.; Seale, W.A.; Silva, C.P.; Gasques, L.; Toufen, D.L.; Silveira, M.A.G.; Zahn, G.S.; Genezini, F.A.; Shorto, J.M.B.; Lubian, J.; Linares, R.

    2011-01-01

    Full text: The following work aims to obtain experimental reaction cross sections of inelastic excitation and transfer to excited states reactions (both measured by gamma-particle coincidences) and its comparison with theoretical predictions based in a new model based on the Sao Paulo Potential. The measurements were made at the Pelletron accelerator laboratory of the University of Sao Paulo with the Saci-Perere spectrometer, which consists of 4 a GeHP Compton suppressed gamma detectors and a 4 π charged particle ancillary system with 11ΔΕ - Ε plastic phoswich scintillators (further details about the experimental procedure may be found in: J.R.B. Oliveira et al., XVIII International School on Nuclear Physics, Neutron Physics and Applications (2009). Theoretical angular distribution calculations (using code GOSIA) were performed with a new model based on the Sao Paulo Potential, specifically developed for the inclusion of dissipative processes like deep-inelastic collisions (DIC) considering the Coulomb plus nuclear potential (with the aid of code FRESCO). The experimental cross sections were obtained such as described in J.R.B. Oliveira et al however, in this work, the particle-gamma angular correlations and the vacuum de-alignment effects (caused by hyperfine interaction) were finally added for the 110 Pd inelastic reaction and for the 112 Pd transfer reaction. For these purposes a new code has been developed to assist in the data analysis. We take into account the particle-gamma angular correlations using the scattering amplitudes given by FRESCO, considering the vacuum de-alignment effects as proposed by A. Abragam and R. V. Pound, Phys. Rev. 92, 943 (1953). The theoretical predictions still consider 2 different types of Sao Paulo Potential, the first one has a multiplying factor equals to 1.0 in the real part of the potential and the second considers this factor equals to 0.6, as proposed in D. Pereira, J. Lubian, J.R.B. Oliveira, D.P. de Sousa and L

  4. Alpha and conversion electron spectroscopy of 238,239Pu and 241Am and alpha-conversion electron coincidence measurements

    Energy Technology Data Exchange (ETDEWEB)

    Dion, Michael P.; Miller, Brian W.; Warren, Glen A.

    2016-09-01

    A technique to determine the isotopics of a mixed actinide sample has been proposed by measuring the coincidence of the alpha particle during radioactive decay with the conversion electron (or Auger) emitted during the relaxation of the daughter isotope. This presents a unique signature to allow the deconvolution of isotopes that possess overlapping alpha particle energy. The work presented here are results of conversion electron spectroscopy of 241Am, 238Pu and 239Pu using a dual-stage peltier-cooled 25 mm2 silicon drift detector. A passivated ion implanted planar silicon detector provided measurements of alpha spectroscopy. The conversion electron spectra were evaluated from 20–55 keV based on fits to the dominant conversion electron emissions, which allowed the relative conversion electron emission intensities to be determined. These measurements provide crucial singles spectral information to aid in the coincident measurement approach.

  5. Field test and evaluation of the IAEA coincidence collar for the measurement of unirradiated BWR fuel assemblies

    International Nuclear Information System (INIS)

    Menlove, H.O.; Keddar, A.

    1982-12-01

    The neutron coincidence counter has been field tested and evaluated for the measurement of boiling-water-reactor (BWR) fuel assemblies at the ASEA-ATOM Fuel Fabrication Facility. The system measures the 235 U content per unit length of full fuel assemblies using neutron interrogation and coincidence counting. The 238 U content is measured in the passive mode without the AmLi neutron interrogatioin source. The field tests included both standard production movable fuel rods to investigate enrichment and absorber variations. Results gave a response standard deviation of 0.9% for the active case and 2.1% for the passive case in 1000-s measurement times. 10 figures, 2 tables

  6. Study of a 4πβ-γ coincidence system for absolute radionuclide activity measurement using plastic scintillators

    International Nuclear Information System (INIS)

    Piuvezam Filho, Helio

    2007-01-01

    The present work was intended to study a coincidence system 4π(PS)β-γ for absolute activity measurement using plastic scintillators in 4π geometry. Along with experiments on the coincidence system, simulations were also performed applying the Monte Carlo Method, by means of codes PENELOPE and ESQUEMA. These simulations were performed in order to calculate the extrapolation curve of the coincidence system 4π(PS)β-γ and compare it to experimental data. A new geometry was proposed to the coincidence system adding up a second photomultiplier tube to the previous system for improving light collection from the plastic scintillator, as this system presented limitations in the minimum detected energy due to the presence of electronic noise and low gain. The results show that an improvement in the signal-to-noise ratio was obtained, as well as in the minimum detected energy. Moreover, there was an increase in the detection efficiency. With these modifications, it is now possible to calibrate radionuclides which emit low energy electrons or X-rays, increasing the number of radionuclides that can be standardized with this type of system.(author)

  7. Uranium cross-calibration measurements using an active well coincidence counter

    International Nuclear Information System (INIS)

    Nikolaev, V.; Prochine, I.; Smirnov, V.; Ensslin, N.; Carillo, L.

    1998-01-01

    This paper reports on the cross-calibration of an Active Well Coincidence Counter for use in the Materials Protection, Control, and Accountability Graduate Program at the Moscow State Engineering Physics Institute (MEPhI). The cross-calibration procedure and its application to nuclear material types available at MEPhI for instructional purposes is described. Cross-calibration results at Los Alamos and initial applications at MEPhI are summarized. Based on the results so far, the authors conclude that the cross-calibration approach seems useful, with good prospects for potential applications at other Russian and US Dept. of Energy facilities

  8. Absolute measurements of the alpha-gamma emitters activities by a sum-coincidence method

    International Nuclear Information System (INIS)

    Tobias, C.C.B.

    1982-01-01

    The absolute activity of U-235 contained in a UO 2 sample, using a sum-coincidence circuit which selected only the alpha particles which were simultaneous with the well known 184 Kev gamma radiation from Th-231. The alpha particles were detected by ZnS(Ag) scintillator specially designed to show its maximun efficiency for U-235 alpha particles, whereas the gamma radiation was detected by NaI(Tl) scintillation detector. The values obtained for the half-life of U-235 was compared with data from various observers using different experimental techniques. (Author) [pt

  9. An automated LS(β)- NaI(Tl)(γ) coincidence system as absolute standard for radioactivity measurements.

    Science.gov (United States)

    Joseph, Leena; Das, A P; Ravindra, Anuradha; Kulkarni, D B; Kulkarni, M S

    2018-07-01

    4πβ-γ coincidence method is a powerful and widely used method to determine the absolute activity concentration of radioactive solutions. A new automated liquid scintillator based coincidence system has been designed, developed, tested and established as absolute standard for radioactivity measurements. The automation is achieved using PLC (programmable logic controller) and SCADA (supervisory control and data acquisition). Radioactive solution of 60 Co was standardized to compare the performance of the automated system with proportional counter based absolute standard maintained in the laboratory. The activity concentrations determined using these two systems were in very good agreement; the new automated system can be used for absolute measurement of activity concentration of radioactive solutions. Copyright © 2018. Published by Elsevier Ltd.

  10. Coincidence measurement between. cap alpha. -particles and projectile-like fragments in reaction of 82. 7 MeV /sup 16/O on /sup 27/Al

    Energy Technology Data Exchange (ETDEWEB)

    Wen-Qing, Shen; Wen-long, Zhan; Yong-tai, Zhu; Shu-zhi, Yin; Zhong-yan, Guo; Wei-min, Qiao; Guo-ying, Fan; Gen-ming, Jin; Song-ling, Li; Zhen, Zhang; others, and

    1987-01-01

    In the coincidence measurement between ..cap alpha..-particles and projectile-like fragments in the reaction of 82.7 MeV /sup 16/O on /sup 27/Al, the contour plot of the C-..cap alpha.. coincidence in the velocity plane and the coincident angular correlation are obtained. Different mechanisms of ..cap alpha..-particle emission are analysed. A possible reaction mechanism of incomplete DIC is discussed.

  11. Coincident measurement between neutron and fragment in reaction sup 1 sup 7 N + sup 1 sup 9 sup 7 Au

    CERN Document Server

    Li Xiang Qing; Jiang Dong Xing; Ye Yan Lin; Chen Tao; Li Zhi Huan; Ge Yuch Eng; Wang Quan Jin; Wu He Yu; Jin Ge; Duan Li Min; Xiao Zhi Gang; Wang Hong Wei; Li Zu Yu; Wang Su Fang

    2002-01-01

    In the reaction induced by 33.4 MeV/u sup 1 sup 7 N beam on sup 1 sup 9 sup 7 Au, the coincident measurement between neutron and fragment was performed with the different combinations of 16 neutron detectors at 4 degree-83 degree and 14 telescopes at 2.3 degree - 9.0 degree. Integrating the measured angular distributions of the different isotopes, the isotopic yield distributions of Z = 3-6 elements are obtained. Based on the Abrasion-ablation model, isotopic yield distributions are calculated using different density distributions for the projectile sup 1 sup 7 N and compared with the experiment data

  12. Absolute 22Na radioactivity measurement by gamma efficiency variation of 4πβ-γ coincidence method

    International Nuclear Information System (INIS)

    Hino, Yoshio; Kawada, Yasusi.

    1994-01-01

    The absolute radioactivity of 22 Na was obtained by gamma efficiency variation of 4πβ-γ coincidence method. Some other previous techniques, such as sum peak gate method based on the positron emission rate, relative measurement with calibrated ionization chambers, and gamma spectrometry with a HPGe detector, were also tried to ensure the present result. The results of these methods were in reasonable agreement with the present absolute measurement. The assayed source solution of this experiment was transferred to NBS type ampoules, and sealed ampoules were sent to the SIR (International Reference System) in BIPM, Taiwan and Indonesia for the international comparison. (author)

  13. The along track scanning radiometer - an analysis of coincident ship and satellite measurements

    Science.gov (United States)

    Barton, I. J.; Prata, A. J.; Llewellyn-Jones, D. T.

    1993-05-01

    Following the successful launch of the ERS-1 satellite in July 1991 we have undertaken several geophysical validation cruises in the Coral Sea. The prime aim of these cruises was to compare the sea surface temperature (SST) derived from the Along Track Scanning Radiometer (ATSR) with that measured using precision radiometers mounted on the ships. On most occasions when simultaneous satellite and ship measurements were taken we also launched a radiosonde from one of the research vessels. The results suggest that the ATSR is able to measure the ``skin'' temperature of the sea surface with an accuracy suitable for climate research applications. A case study comparison between the AVHRR and ATSR SST products will also be presented.

  14. Preliminary results of oxygen isotope ratio measurement with a particle-gamma coincidence method

    Energy Technology Data Exchange (ETDEWEB)

    Borysiuk, Maciek, E-mail: maciek.borysiuk@pixe.lth.se; Kristiansson, Per; Ros, Linus; Abdel, Nassem S.; Elfman, Mikael; Nilsson, Charlotta; Pallon, Jan

    2015-04-01

    The possibility to study variations in the oxygen isotopic ratio with photon tagged nuclear reaction analysis (pNRA) is evaluated in the current work. The experiment described in the article was performed at Lund Ion Beam Analysis Facility (LIBAF) with a 2 MeV deuteron beam. Isotopic fractionation of light elements such as carbon, oxygen and nitrogen is the basis of many analytical tools in hydrology, geology, paleobiology and paleogeology. IBA methods provide one possible tool for measurement of isotopic content. During this experimental run we focused on measurement of the oxygen isotopic ratio. The measurement of stable isotopes of oxygen has a number of applications; the particular one driving the current investigation belongs to the field of astrogeology and specifically evaluation of fossil extraterrestrial material. There are three stable isotopes of oxygen: {sup 16}O, {sup 17}O and {sup 18}O. We procured samples highly enriched with all three isotopes. Isotopes {sup 16}O and {sup 18}O were easily detected in the enriched samples, but no significant signal from {sup 17}O was detected in the same samples. The measured yield was too low to detect {sup 18}O in a sample with natural abundances of oxygen isotopes, at least in the current experimental setup, but the spectral line from the reaction with {sup 16}O was clearly visible.

  15. The Coincidence Tracker: Electronic Equipment for a Time-of-Flight Wind-Speed Measurement System

    DEFF Research Database (Denmark)

    Fog, Christian

    1982-01-01

    The electronic part of a laser-beam measuring system for wind velocity is described. Pulses of light scattered from aerosols are treated, first in a pair of adaptive filters, then in a tracker that calculates the wind velocity on-line while applying some knowledge about the velocity to be expected...

  16. Absolute nuclear energy measurements using the γ-γ coincidence method

    International Nuclear Information System (INIS)

    Benoit, P.; Philis, C.

    1967-01-01

    I n this report a summary is first given of the principle of the γ-γ calibration method, stress being laid on the corrections required. After a description of the equipment used, the choice of the experimental conditions required for various isotopes is discussed ( 22 Na, 46 Sc, 60 Co, 88 Y) and the agreement between these results and those obtained by other absolute measurement methods is considered. (authors) [fr

  17. HYDICE data from Lake Tahoe: comparison to coincident AVIRIS and in-situ measurements

    Science.gov (United States)

    Kappus, Mary E.; Davis, Curtiss O.; Rhea, W. J.

    1996-11-01

    Coordinated flights of two calibrated airborne imaging spectrometers, HYDICE and AVIRIS, were conducted on June 22, 1995 over Lake Tahoe. As part of HYDICE's first operational mission, one objective was to test the system performance over the dark homogeneous target provided by the clear deep waters of the lake. The high altitude and clear atmosphere makes Lake Tahoe a simpler test target than near-shore marine environments, where large aerosols complicate atmospheric correction and sediment runoff and high chlorophyll levels make interpretation of he data difficult. Calibrated data from both runoff and high chlorophyll levels make interpretation of the data difficult. Calibrated data from both sensors was provided in physical units of radiance. The atmospheric radiative transfer code, MODTRAN was used to remove the path radiance between the ground and sensor and the skylight reflected from the water surface. The resulting water-leaving spectrometer, and with values calculated form in-water properties using the HYDROLIGHT radiative transfer code. The agreement of the water-leaving radiance for the HYDICE data, the ground-truth spectral measurements, and the results of the radiative transfer code are excellent for wavelengths greater than 0.45 micrometers . The AVIRIS flight took place more than an hour closer to noon, which makes the radiance measurements not directly comparable. Comparisons to radiative transfer output for this later time indicate that the AVIRIS data is strongly by sun glint. Because water-leaving radiance is dependent upon the characteristics of the water, it can be analyzed for some of those properties. Using the CZCS algorithm based on the water-leaving radiance at two wavelengths, the chlorophyll content of Lake Tahoe was computed from the HYDICE and ground-truth data. Resulting values are slightly higher than measurements made two weeks earlier from water samples, indicating a growth in the phytoplankton population which is very plausible

  18. Note: Coincidence measurements of 3He and neutrons from a compact D-D neutron generator

    Science.gov (United States)

    Ji, Q.; Lin, C.-J.; Tindall, C.; Garcia-Sciveres, M.; Schenkel, T.; Ludewigt, B. A.

    2017-05-01

    Tagging of neutrons (2.45 MeV) with their associated 3He particles from deuterium-deuterium (D-D) fusion reactions has been demonstrated in a compact neutron generator setup enabled by a high brightness, microwave-driven ion source with a high fraction of deuterons. Energy spectra with well separated peaks of the D-D fusion reaction products, 3He, tritons, and protons, were measured with a silicon PIN diode. The neutrons were detected using a liquid scintillator detector with pulse shape discrimination. By correlating the 3He detection events with the neutron detection in time, we demonstrated the tagging of emitted neutrons with 3He particles detected with a Si PIN diode detector mounted inside the neutron generator vacuum vessel.

  19. A tewlve detector coincidence spectrometer for on-line and off-line measurements of nuclear g-factors

    International Nuclear Information System (INIS)

    Alfter, I.; Bodenstedt, E.; Hamer, B.; Hoff, J. van den; Knichel, W.; Muenning, H.; Piel, S.; Schueth, J.; Sajok, R.

    1992-01-01

    A twelve detector γ-γ directional correlation setup is described which has been designed and constructed for high precision on-line and off-line IPAC measurements. A ring of twelve BaF 2 detectors which may be replaced by Ge detectors is arranged around a superconducting magnet providing a maximum magnetic field of 4.5 T. In on-line experiments the magnetic field has the direction of the beam which passes through a central bore of the magnet. The data acquisition system stores directly the Esub(γ 1 )-Esub(γ 2 ) coincidence matrices for all 66 two-detector combinations in two 8 Mbyte RAMs, one for each of the two field directions. This allows a very fast data evaluation with a small on-line computer. The apparatus got into operation one-and-a-halve years ago and revealed excellent properties. (orig.)

  20. Measurement of cone beam CT coincidence with megavoltage isocentre and image sharpness using the QUASAR Penta-Guide phantom.

    Science.gov (United States)

    Sykes, J R; Lindsay, R; Dean, C J; Brettle, D S; Magee, D R; Thwaites, D I

    2008-10-07

    For image-guided radiotherapy (IGRT) systems based on cone beam CT (CBCT) integrated into a linear accelerator, the reproducible alignment of imager to x-ray source is critical to the registration of both the x-ray-volumetric image with the megavoltage (MV) beam isocentre and image sharpness. An enhanced method of determining the CBCT to MV isocentre alignment using the QUASAR Penta-Guide phantom was developed which improved both precision and accuracy. This was benchmarked against our existing method which used software and a ball-bearing (BB) phantom provided by Elekta. Additionally, a method of measuring an image sharpness metric (MTF(50)) from the edge response function of a spherical air cavity within the Penta-Guide phantom was developed and its sensitivity was tested by simulating misalignments of the kV imager. Reproducibility testing of the enhanced Penta-Guide method demonstrated a systematic error of <0.2 mm when compared to the BB method with near equivalent random error (s=0.15 mm). The mean MTF(50) for five measurements was 0.278+/-0.004 lp mm(-1) with no applied misalignment. Simulated misalignments exhibited a clear peak in the MTF(50) enabling misalignments greater than 0.4 mm to be detected. The Penta-Guide phantom can be used to precisely measure CBCT-MV coincidence and image sharpness on CBCT-IGRT systems.

  1. Coincidence studies with antiprotons

    Energy Technology Data Exchange (ETDEWEB)

    McGovern, M; Walters, H R J [Department of Applied Mathematics and Theoretical Physics, Queen' s University, Belfast BT7 1NN (United Kingdom); Assafrao, D; Mohallem, J R [Laboratorio de Atomos e Moleculas Especiais, Departamento de Fisica, ICEx, Universidade Federal de Minas Gerais, P.O Box 702, 30123-970 Belo Horizonte, MG (Brazil); Whelan, Colm T, E-mail: mmcgovern06@qub.ac.u [Department of Physics, Old Dominion University, Norfolk, VA 23529-0116 (United States)

    2010-02-01

    We present a short overview of a new method for calculating fully differential cross sections that is able to describe any aspect of coincidence measurements involving heavy projectiles. The method is based upon impact parameter close coupling with pseudostates. Examples from antiproton impact ionization are shown.

  2. Experiments using coincidence methods

    International Nuclear Information System (INIS)

    Anwar Dhani.

    1978-01-01

    Experiments on γ spectroscopy using the simple coincidence techniques, including investigation of angular distribution of γ radiation from annihilation process in decay of Na 22 , γ - γ angular correlation technique in decay of Co 60 , decay scheme study of Bi 207 and life time measurement of nuclear Pb 207 excited state have been carried out. (author)

  3. Coincidence measurements of slow recoil ions with projectile ions in 42-MeV Arq+-Ar collisions

    International Nuclear Information System (INIS)

    Tonuma, T.; Kumagai, H.; Matsuo, T.; Tawara, H.

    1989-01-01

    Slow Ar recoil-ion production cross sections by projectiles of 1.05-MeV/amu Ar q+ (q=4,6,8,10,12,14) were measured using a projectile-ion--recoil-ion coincidence technique. The present results indicate that the average recoil ion charges left-angle i right-angle increase with increasing the incident projectile charge q and the number of the lost and captured electrons from and/or into projectiles, whereas the projectile charge-changing cross sections for loss ionization decrease steeply with increasing q for low-charge-state projectiles, and those for transfer ionization increase rapidly with increasing q for high-charge-state projectiles. For Ar projectiles with q=10, which corresponds to the equilibrium charge state of Ar projectiles at the present collision energy, the average recoil-ion charges are nearly the same in both loss and transfer ionization, and a pure ionization process plays a much more important role in producing highly charged recoil ions, in contrast to projectile electron loss or transfer processes, which play a role in other projectile charge states

  4. Design for measurement system of Doppler broadening profiles with the coincidence technique using a NaI detector in colinear geometry with the Ge detector

    International Nuclear Information System (INIS)

    Mori, Kazuteru; Uedono, Akira; Tanigawa, Shoichiro; Nakai, Katsuhiko

    1998-01-01

    The measurement system for Doppler broadening profiles with the coincidence technique using a NaI detector in colinear geometry with a Ge detector was developed. The principle of measurement system with the coincidence technique between the NaI detector and the Ge detector was described. Application of the system for the detection of vacancy-type defects introduced by electron irradiation in Czochralski-(Cz) grown Si was shown. Detail in the difference between the Doppler broadening profiles for Cz-Si and Si grown by the floating-zone method was also obtained. (author)

  5. Design for measurement system of Doppler broadening profiles with the coincidence technique using a NaI detector in colinear geometry with the Ge detector

    Energy Technology Data Exchange (ETDEWEB)

    Mori, Kazuteru; Uedono, Akira; Tanigawa, Shoichiro [Tsukuba Univ., Ibaraki (Japan). Inst. of Materials Science; Nakai, Katsuhiko

    1998-08-01

    The measurement system for Doppler broadening profiles with the coincidence technique using a NaI detector in colinear geometry with a Ge detector was developed. The principle of measurement system with the coincidence technique between the NaI detector and the Ge detector was described. Application of the system for the detection of vacancy-type defects introduced by electron irradiation in Czochralski-(Cz) grown Si was shown. Detail in the difference between the Doppler broadening profiles for Cz-Si and Si grown by the floating-zone method was also obtained. (author)

  6. Coincidence measurements in α/β/γ spectrometry with phoswich detectors using digital pulse shape discrimination analysis

    Science.gov (United States)

    de Celis, B.; de la Fuente, R.; Williart, A.; de Celis Alonso, B.

    2007-09-01

    A novel system has been developed for the detection of low radioactivity levels using coincidence techniques. The device combines a phoswich detector for α/β/γ ray recognition with a fast digital card for electronic pulse analysis. The detector is able to discriminate different types of radiation in a mixed α/β/γ field and can be used in a coincidence mode by identifying the composite signal produced by the simultaneous detection of β particles in a plastic scintillator and γ rays in an NaI(Tl) scintillator. Use of a coincidence technique with phoswich detectors was proposed recently to verify the Nuclear Test Ban Treaty, which made it necessary to monitor the low levels of xenon radioisotopes produced by underground nuclear explosions. Previous studies have shown that combining CaF 2(Eu) for β ray detection and NaI(Tl) for γ ray detection makes it difficult to identify the coincidence signals because of the similar fluorescence decay times of the two scintillators. With the device proposed here, it is possible to identify the coincidence events owing to the short fluorescence decay time of the plastic scintillator. The sensitivity of the detector may be improved by employing liquid scintillators, which allow low radioactivity levels from actinides to be measured when present in environmental samples. The device developed is simpler to use than conventional coincidence equipment because it uses a single detector and electronic circuit, and it offers fast and precise analysis of the coincidence signals by employing digital pulse shape analysis.

  7. Measurement of highly enriched uranium metal buttons with the high-level neutron coincidence counter operating in the active mode

    International Nuclear Information System (INIS)

    Foley, J.E.

    1980-10-01

    The portable High-Level Neutron Coincidence Counter is used in the active mode with the addition of AmLi neutron sources to assay the 235 U content of highly enriched metal pieces or buttons. It is concluded that the portable instrument is a practical instrument for assaying uranium metal buttons with masses in the range 1.5 to 4 kg

  8. Elaboration of Co-60 sources on gilding vyns, with beta efficiencies 80 % or better and its activity measure by the coincidences method

    International Nuclear Information System (INIS)

    Cortes P, A.; Tejera R, A.; Becerril V, A.; Ortiz C, A.

    1991-12-01

    The measuring technique of radioactive activity by the coincidences method 4 π β - γ it requires of the elaboration of radioactive sources on thin supports in order to flows the biggest percentage of beta particles, those of the order of the 80 % or but. In this work a procedure for the elaboration of this type of sources, with gilding Vyns is reported. (Author)

  9. Coincidence measurements of the (. pi. /sup +/,. pi. /sup 0/p) reaction in the /triangle/-resonance region

    Energy Technology Data Exchange (ETDEWEB)

    Hoeibraten, S.

    1989-05-01

    This thesis describes an experimental study of the (..pi../sup +/, ..pi../sup 0/p) reaction at incident energy T/sub ..pi../sup +// = 165 MeV. This work is part of the first experiment to detect neutral pions and protons in coincidence in kinematically complete measurements. The reaction was studied on /sup 16/O (using water targets) at several pion angles: theta/sub ..pi../sup 0// = 70/degree/, 80/degree/, 110/degree/, and 130/degree/. At theta/sub ..pi../sup 0// = 110/degree/ measurements were also made on /sup 56/Fe, /sup 120/Sn, and /sup 208/Pb. The neutral pions were detected with the LAMPF ..pi../sup 0/ spectrometer, while the protons were detected in a vertical array of plastic-scintillator ..delta..E-E telescopes, each spanning 8.5 msr. Energy spectra of the differential cross sections d/sup 4/sigma/dE/sub ..pi../sup 0// dE/sub p/d..cap omega../sub ..pi../sup 0//d..cap omega../sub p/ were obtained for each proton telescope and subsequently integrated over proton and pion energy and proton angle. The characteristics of these spectra are consistent with a quasi-free description of the (..pi../sup +/,..pi../sup 0/p) reaction. The angular dependence of dsigma/d..cap omega../sub ..pi../sup 0//(theta/sub ..pi../sup 0//) for /sup 16/O(..pi../sup +/,..pi../sup 0/p) was found to be in accordance with that of the cross section for the corresponding free reaction at backward ..pi../sup 0/ angles. For the /sup 16/O(..pi../sup +/,..pi../sup 0/p) reaction, events in which a p-shell nucleon had been removed were identified. The p-shell events were found to constitute only 40--50% of the total cross section for quasi-free one-nucleon removal. The (..pi../sup +/,..pi../sup 0/p) cross section at theta/sub ..pi../sup 0// = 110/degree/ proved to be almost the same for all target nuclei, possibly slightly decreasing as a function of A. 102 refs., 108 figs., 24 tabs.

  10. Three-gamma annihilation of ortho-positronium in NiO/γ-Al2O3 catalysts detected by positron lifetime and coincidence Doppler broadening measurements

    International Nuclear Information System (INIS)

    Huang, S.H.; Chen, Z.Q.; Zhang, H.J.

    2012-01-01

    The pore structure of NiO/γ-Al 2 O 3 catalysts is characterized by positron lifetime and Doppler broadening measurements. A very long lifetime τ 4 of 92 ns is resolved from the positron lifetime spectrum measured for pure Al 2 O 3 , which could be attributed to the ortho-positronium (o-Ps) lifetime in large pores. It was also found that the fitted lifetime τ 4 and its corresponding intensity I 4 obtained from the lifetime spectra both decrease with narrowing energy window of the stop channel in the fast–fast coincidence lifetime measurement system. This suggests that the ultra long lifetime is primarily due to the self annihilation of o-Ps which emits three gamma-rays. Such 3γ annihilation is further evidenced by measuring the Doppler broadening of annihilation gamma rays in coincidence with the prompt gamma rays (1.28 MeV) emitted from the 22 Na positron source. In NiO/γ-Al 2 O 3 catalysts both the lifetime τ 4 and its intensity I 4 decreases with increasing NiO content (from 3 wt% to 40 wt%), which indicates decreasing of the number of 3γ events. The 3γ annihilation parameter analyzed from the coincidence Doppler broadening spectrum shows consistent decrease with increasing NiO content. - Highlights: ► Above paper reported study of the 3-gamma annihilation of o-Ps. ► 3γ annihilation was verified by varying the energy window of the lifetime system. ► A new coincidence Doppler broadening technique is also used to record 3γ events. ► 3γ parameter decreases with NiO content in NiO/γ-Al 2 O 3 catalysts.

  11. Alpha and conversion electron spectroscopy of {sup 238,239}Pu and {sup 241}Am and alpha-conversion electron coincidence measurements

    Energy Technology Data Exchange (ETDEWEB)

    Dion, Michael P., E-mail: michael.dion@pnnl.gov; Miller, Brian W.; Warren, Glen A.

    2016-09-11

    A technique to determine the isotopic constituents of a mixed actinide sample has been proposed by a coincident alpha-conversion electron measurement. This presents a unique signature to allow the unfolding of isotopes that possess overlapping alpha particle energy and reduce backgrounds of an unseparated sample. The work presented here are results of conversion electron spectroscopy of {sup 241}Am, {sup 238}Pu and {sup 239}Pu using a dual-stage peltier-cooled 25 mm{sup 2} silicon drift detector and alpha spectroscopy with a passivated ion implanted planar silicon detector. The conversion electron spectra were evaluated from 20–55 keV based on fits to the dominant conversion electron emissions, which allowed the relative conversion electron emission intensities to be determined. These measurements provide crucial singles spectral information and calibration to aid in the coincident measurement approach. Furthermore, an alpha-conversion electron spectrometer was assembled using the silicon based detectors described and results of a coincident spectrum analysis is reported for {sup 241}Am.

  12. Measurement of disintegration rate and decay branching ratio for nuclide 192Ir with β-, EC mixing decays by using 4πβ-γ coincidence counting

    International Nuclear Information System (INIS)

    Yan Chunguang; Pei Wulang; Li Wei; Qu Decheng; Xiong Jing; Chang Yongfu

    1995-01-01

    The absolute disintegration rates for nuclide 192 Ir were measured with a 4πβ-γ (HPGe) coincidence apparatus by using parameter method and extrapolation method. The final uncertainties obtained were 0.4% and 0.5% respectively for a confidence level of 99.7%. The method with which both the disintegration rate and the decay branching ratio can be measured for nuclides with β - and EC mixing decays was proposed and described. The β - branching ratio in 192 Ir decays was measured being 0.9572. The final uncertainties of disintegration rates and β - decay branching ratio with this method were 1.5% and 1.8% respectively

  13. Coincidence measurement between α-particles and projectile-like fragments in the reaction of 82.7 MeV 16O on 27Al

    International Nuclear Information System (INIS)

    Shen Wenqing; Zhan Wenlong; Zhu Yongtai

    1988-01-01

    In a coincidence measurement between α-particles and projectile-like fragments in the reaction of 82.7 MeV 16 O on 27 Al, the contour plot of Galilean-invariant cross section of the coincidence between C-fragments and α-particles in the velocity plane, and the coincident angular correlation have been obtained. The correlated α-particles measured at positive angles (on the same side of the beam as the projectile-like fragments) were emitted mainly from the projectile-like fragments;the α-particles at large negative angles were emitted from the target-like fragments;the α-particles at small negative angles came from the fragmentation of the 16 O projectile. A possible reaction mechanism in which the residue produced in the fragmentation of the projectile continues the dissipation process during the interaction with the target has been discussed. It is also pointed out that in the large yield of C-fragments observed in the inclusive experiment, the contribution of C-fragments produced by the excited 16 O of DIC product via α-emission is quite small

  14. Measurements of radionuclide activity by the (e-α, β, γ, Lx) coincidence method using electrons with energies of a few eV emitted from radionuclides

    International Nuclear Information System (INIS)

    Frolov, E.A.

    1994-01-01

    A study was made of the possibility of measuring radionuclide activities by the method of coincidence of electrons with energies of a few eV emitted from the valence shells of radioactive atoms with nuclear radiations. The low energy electrons were detected with a detector equipped with microchannel plates with trochoidal focusing of an original design. Photons were detected with NaI(TI) detectors. A 100 μm thick plastic scintillator was used to detect beta- and alpha-particles. The investigation shows that it is possible to use this method for accurate measurements of radionuclide activity. (orig.)

  15. Measurements to determine the sulfuric acid dew point and the SO sub 3 concentration in flue gas of power plant vessels. Messungen zur Bestimmung des Saeuretaupunktes und der SO sub 3 -Konzentration im Rauchgas von Kraftwerkskesseln

    Energy Technology Data Exchange (ETDEWEB)

    Derichs, W.; Menden, W. (RWE Energie AG, Bergheim (Germany)); Ebel, P.K. (Apparatebau Hundsbach GmbH, Baden-Baden (Germany))

    1990-01-01

    Among the customary methods of dew point determination, the technique of recording the increase in conductivity between two electrodes at the moment of acid condensing onto them, and measuring at the same time the temperature of the sensor, is appropriate to determine the sulfuric acid dew point in dust-laden flue gas. By means of the sensitivity of a newly developed sensor, the accuracy of the measurement method could be improved to such an extent that also low acid dew points and rapid changes can be recorded reliably. Measurements have shown that the acid dew point primarily depends on the SO{sub 3} content which is substantially determined by the sulfur content of the fuel and the type of flue gas ducts. Further influential quantities include flue gas humidity, air surplus, other gaseous flue gas components such as HCl and HF, as well as the quantity, composition and temperature-dependent adsorption capability of the flue dusts. (orig./BBR).

  16. Determination of the deposition of polycyclic aromatic hydrocarbons (PAHs) to soil at Scheyern and Kirchheim near Munich; Bestimmung der Eintraege von polyzyklischen aromatischen Kohlenwasserstoffen (PAHs) an den Standorten Scheyern und Kirchheim bei Muenchen

    Energy Technology Data Exchange (ETDEWEB)

    Krainz, A; Wiedenmann, M; Maguhn, J [GSF-Forschungszentrum fuer Umwelt und Gesundheit Neuherberg (Germany). Inst. fuer Oekologische Chemie

    1998-12-31

    Task force 1, ``Analysis of the exposure of soils``, carried out comprehensive and site-specific measurements of the transfer of environmental chemicals into soil by means of the example of s-triazines and polycyclic aromatic hydrocarbons (PAHs). This work was in four parts: a: Determination of PAH nuisance concentrations in selected sites (Juelich, Scheyern, Bad Lauchstaedt); b: Measurement of wet deposition, development and use of methods for the determination of dry deposition; c: Statements regarding large-area PAH transfer into soil in Germany; d: Modelling of the rates of dry deposition. (orig.) [Deutsch] Aufgabe der Arbeitsgruppe 1 `Belastungsanalyse von Boeden`: Flaechendeckende sowie standortbezogene Erfassung der Eintraege von Umweltchemikalien am Beispiel der s-Triazine und PAHs. a: Bestimmung der Immissionskonzentrationen von PAHs an den Schwerpunktstandorten (Juelich, Scheyern, Bad Lauchstaedt) b: Messung der Nassen Deposition, Entwicklung und Anwendung von Methoden zur Bestimmung der Trockenen Deposition c: Aussagen ueber flaechendeckende Eintraege von PAHs in der Bundesrepublik d: Modellierung der Trockendepositionsraten. (orig.)

  17. Determination of the deposition of polycyclic aromatic hydrocarbons (PAHs) to soil at Scheyern and Kirchheim near Munich; Bestimmung der Eintraege von polyzyklischen aromatischen Kohlenwasserstoffen (PAHs) an den Standorten Scheyern und Kirchheim bei Muenchen

    Energy Technology Data Exchange (ETDEWEB)

    Krainz, A.; Wiedenmann, M.; Maguhn, J. [GSF-Forschungszentrum fuer Umwelt und Gesundheit Neuherberg (Germany). Inst. fuer Oekologische Chemie

    1997-12-31

    Task force 1, ``Analysis of the exposure of soils``, carried out comprehensive and site-specific measurements of the transfer of environmental chemicals into soil by means of the example of s-triazines and polycyclic aromatic hydrocarbons (PAHs). This work was in four parts: a: Determination of PAH nuisance concentrations in selected sites (Juelich, Scheyern, Bad Lauchstaedt); b: Measurement of wet deposition, development and use of methods for the determination of dry deposition; c: Statements regarding large-area PAH transfer into soil in Germany; d: Modelling of the rates of dry deposition. (orig.) [Deutsch] Aufgabe der Arbeitsgruppe 1 `Belastungsanalyse von Boeden`: Flaechendeckende sowie standortbezogene Erfassung der Eintraege von Umweltchemikalien am Beispiel der s-Triazine und PAHs. a: Bestimmung der Immissionskonzentrationen von PAHs an den Schwerpunktstandorten (Juelich, Scheyern, Bad Lauchstaedt) b: Messung der Nassen Deposition, Entwicklung und Anwendung von Methoden zur Bestimmung der Trockenen Deposition c: Aussagen ueber flaechendeckende Eintraege von PAHs in der Bundesrepublik d: Modellierung der Trockendepositionsraten. (orig.)

  18. Development of an in-situ diagnostic for the measurement of the hydrogen content of amorphous hydrocarbon layers in fusion devices; Entwicklung einer In-situ-Messmethode zur Bestimmung des Wasserstoffgehalts amorpher Kohlenwasserstoffschichten in Fusionsanlagen

    Energy Technology Data Exchange (ETDEWEB)

    Irrek, F.

    2008-07-15

    A diagnostic method, the laser-induced thermal desorption spectroscopy (LDS), is developed to measure in situ the hydrogen inventory in the surface of plasma-facing components in fusion experiments. Its capabilities will be demonstrated in TEXTOR. In LDS, during the plasma discharge a laser beam is used to heat a spot on a surface close to the plasma to a temperature of 1400 to 2100 K to a depth of 100 {mu}m. Trapped hydrogen will be released into the plasma where it emits line radiation. The emitted H{sub a}-light is quantitatively measured. The amount of released hydrogen is calculated from the intensity of this emission using conversion factors (S/XB){sub eff}. The laser light (Nd:YAG, 1064 nm) is conducted via light fibres. At TEXTOR, a 5 mm{sup 2} sized homogeneous laser spot is created with a pulse duration of 1.5 ms, and an Energy of 5 J, typically. Below the laser spot a volume of at most 1 mm{sup 3} is desorbed. The generated temperature is calculated numerically and indirectly deduced from surface changings. Depending on the conditions during the layer formation the hydrogen content of the hydrocarbon layer will vary and different fractions of the released molecules (H{sub 2}, CH{sub 4}, C{sub 2}H{sub 4}) are created during the laser heating. The release of atomic hydrogen by laser desorption was not found. The emitted light is measured by means of narrow-band interference filters and a CCD-camera. The fraction of the light emission which lies outside the observation volume is estimated using simulations of the emission by the neutral gas transport Monte Carlo code EIRENE for each molecular fraction. Conversion factors (S/XB){sub eff} were measured in various reference plasmas (T{sub e}=22-30 eV, n{sub e}=1-11 x 10{sup 18} m{sup -3} and T{sub e}=50-74 eV, n{sub e}=1-5 x 10{sup 18} m{sup -3}) by desorbing prepared graphite samples which release a known amount of hydrogen with a known molecular distribution. LDS measurements were carried out in TEXTOR at

  19. In vivo measurement of Pb-210 in the skull for retrospective assessment of exposure to radon; Die in-vivo Messung von Pb-210 im Schaedel zur retrospektiven Bestimmung von Radon-Expositionen

    Energy Technology Data Exchange (ETDEWEB)

    Doerfel, H. [Forschungszentrum Karlsruhe GmbH (Germany). Hauptabteilung Sicherheit/Dosimetrie

    1997-12-01

    The study shows that the new HPGe detectors with a larger surface are significantly better in terms of results and performance than the Phoswich detectors hitherto used for in vivo measurement of Pb-210 in the human skull. The experimental evaluations indicate that smaller HPGe detectors likewise are better than the Phoswich detectors, but some additional studies are required for final evaluation of these instruments. (orig./CB) [Deutsch] Die Untersuchungen haben gezeigt, dass die neuen grossflaechigen HPGe-Detektoren wesentlich besser zur in-vivo Messung von Pb-210 im Skelett geeignet sind als die bisher eingesetzten Phoswich-Detektoren. Auch kleinere HPGe-Detektoren sind offenbar besser geeignet als Phoswich-Detektoren, allerdings sind hier noch einige ergaenzende Untersuchungen erforderlich. (orig./SR)

  20. Measurement of the driving behaviour of vehicle owners in a tunnel for the determination of the CO-emission. Messung des Fahrverhaltens eines Verkehrskollektivs in einem Strassentunnel zwecks Bestimmung der CO-Emission

    Energy Technology Data Exchange (ETDEWEB)

    Eberan-Eberhorst, R.; Lenz, H.P.; Bruner-Newton, I.

    1978-01-01

    During the summer of 1977, the speeds of 5742 motor vehicles were registered in the Katschbergtunnel. On the basis of the average speed, the frequency distribution of the speed increases and decreases of the individual vehicles between the loops, the reference distance, the reference time and the average maximum speed difference in the tunnel, a tunnel cycle was elaborated, reproducing the representative driving behaviour of the individual vehicle in the Katschbergtunnel. The tunnel cycle shows a driving behaviour with speeds fluctuating around the average speed of 74 km/h (46 m.p.h.) and corresponds to a steady traffic flow. The CO-emission during constant driving at 74 km/h (46 m.p.h.) and the CO-emission in the tunnel cycle were measured during test drives with eight test vehicles on the dynamometer of the Institute for Internal Combustion Engines and Automotive Engineering (Institut fuer Verbrennungskraftmaschinen und Kraftfahrwesen) of the Technical University Vienna.

  1. Absolute measurement of the desintegration rate of 137 Cs by 4Π (BS) e--X coincidence method

    International Nuclear Information System (INIS)

    Koskinas, M.F.; Dias, M.S.

    1989-01-01

    The method developed by the Nuclear Metrology Laboratory for the absolute measurement of the desintegration rate of 137 Cs by 4Π(BS)e - -X is described. The conversion electron are measured by a pair of surface barrier detectors with 200mm 2 of active area and 1000μm of depletion depth. The X-rays are measured by two 50.8mm diameter and 1.0mm thick NaI (Tl) scintillation counters. (author) [pt

  2. Assessment of the geometric coincidence of neutron and gamma probe measurements with solo 40 and CPN 501 B

    International Nuclear Information System (INIS)

    Valles, V.; Guiresse, M.; Tcherbakov, R.

    1989-01-01

    The distance between the gamma and neutron probe measurement centres was determined for the Nardeux Solo 40 and CPN 501 B probes. The centre of the spheres of influence was localized using a water-air interface constituted by a metal cylinder filled with 200 liters of water. For Solo 40, the discrepancy between the two measurement centres was 6 cm. This shift value, which is quite acceptable, does not require any correction for these measurements, even when the soil is heterogeneous. For CNP 501 B, the discrepancy between the neutron and gamma measurement was 11 cm, i.e. nearly twice the value observed with Solo 40. In soils with a marked vertical heterogeneity, it therefore seems preferable to operate a 11 cm shift of the probe between the moisture and density measurements [fr

  3. Precision measurement of sub-nanosecond lifetimes of excited nuclear states using fast-timing coincidences with LaBr3(Ce) detectors

    International Nuclear Information System (INIS)

    Regan, P.H.

    2015-01-01

    Precision measurements of electromagnetic (EM) transition rates enable tests of models of internal nuclear structure. Measurements of transition rates can be used to infer the spin and parity differences between the initial and final discrete nuclear excited states via which the EM transition takes place. This short conference paper reports on developments of detection systems for the identification of discrete energy gamma-ray decays using arrays of halide-scintillation detectors acting in coincidence mode, which can be used to determine electromagnetic transition rates between excited nuclear states in the sub-nanosecond temporal regime. Ongoing development of a new multi-detector LaBr 3 (Ce) array for studies of exotic nuclei produced at the upcoming Facility for Anti-Proton and Ion Research (FAIR) as part of the NUSTAR–DESPEC project are presented, together with initial results from pre-NUSTAR implementations of this array for nuclear structure studies of neutron-rich fission fragment radionuclides at ILL-Grenoble, France and RIBF at RIKEN, Japan. - Highlights: • This paper reports on new detection systems for identification of gamma decays. • It focusses on using arrays of halide-scintillation detectors in coincidence mode. • These can determine lifetimes of nuclear states at the sub-ns level. • Plans for new LaBr3(Ce) arrays for studies of exotic nuclei are presented.

  4. The effect of weak neutral currents on the coincidence of e+ and e- particles and the combined theories of measures

    International Nuclear Information System (INIS)

    Lendvai, E.

    1978-01-01

    The electromagnetic and weak interactions as well as the spontaneously broken measures were reviewed. Some characteristic structures and models were described including the most favoured one proposed by Weinberg and Salem. The effect of weak neutral currents were investigated in the processes e + e - → Σ hadron, MantiM, FantiF; the asymmetries of these processes were calculated. The weak effects found were rather significant in the energy range q = 14-40 GeV reaching a maximum of 20%. It was suggested that the measurements of these effects provided useful information about the structure of weak neutral currents. (Z.P.)

  5. Observations of Bathymetry-Induced Ocean Roughness Modulation in In-situ Surface Slope Measurements and Coincident Airborne SAR Images

    NARCIS (Netherlands)

    Gommenginger, C.P.; Robinson, I.S.; Willoughby, J.; Greidanus, H.S.F.; Taylor, V.

    1999-01-01

    Empirical results from a field experiment in the southern North Sea have demonstrated the possibility to detect bathymetry-induced sea surface roughness modulation in the coastal zone using high frequency in-situ slope measurements provided by the Towed Laser Slopemeter. A strong correlation between

  6. Effect of double false pulses in calibrated neutron coincidence collar during measuring time-correlated neutrons from PuBe neutron sources

    Energy Technology Data Exchange (ETDEWEB)

    Nguyen, Tam Cong, E-mail: tam.nguyen.cong@energia.mta.hu; Huszti, Jozsef; Nguyen, Quan Van

    2015-09-01

    Effect of double false pulses of preamplifiers in neutron coincidence collar was investigated to explain non-parallel shape of calibrated D/S–M{sub Pu} curves of two commercial neutron coincidence collars, JCC-31 and JCC-13. Two curves, which were constructed from D/S ratio (doubles and singles count rate), and Pu content M{sub Pu}, of the same set of secondary standard PuBe neutron sources, should be parallel. Non-parallelism rises doubt about usability of the method based on this curve for determination of Pu content in PuBe neutron sources. We have shown in three steps that the problem originates from double false pulses of preamplifiers in JCC-13. First we used a pulse train diagram for analyzing the non-parallel shape, second we used Rossi-Alpha distribution measured by pulse train recorder developed in our institute and finally, we investigated the effect of inserted noise pulses. This implies a new type of QA test option in traditional multiplicity shift registers for excluding presence of double false pulses.

  7. Cosmic-muon intensity measurement and overburden estimation in a building at surface level and in an underground facility using two BC408 scintillation detectors coincidence counting system.

    Science.gov (United States)

    Zhang, Weihua; Ungar, Kurt; Liu, Chuanlei; Mailhot, Maverick

    2016-10-01

    A series of measurements have been recently conducted to determine the cosmic-muon intensities and attenuation factors at various indoor and underground locations for a gamma spectrometer. For this purpose, a digital coincidence spectrometer was developed by using two BC408 plastic scintillation detectors and an XIA LLC Digital Gamma Finder (DGF)/Pixie-4 software and card package. The results indicate that the overburden in the building at surface level absorbs a large part of cosmic ray protons while attenuating the cosmic-muon intensity by 20-50%. The underground facility has the largest overburden of 39 m water equivalent, where the cosmic-muon intensity is reduced by a factor of 6. The study provides a cosmic-muon intensity measurement and overburden assessment, which are important parameters for analysing the background of an HPGe counting system, or for comparing the background of similar systems. Copyright © 2016 Elsevier Ltd. All rights reserved.

  8. Coincidence measurements of intermediate mass fragments produced in /sup 32/S-induced reactions on Ag at E/A = 22.5 MeV

    International Nuclear Information System (INIS)

    Fields, D.J.; Lynch, W.G.; Nayak, T.K.

    1986-01-01

    Single- and two-particle inclusive cross sections for the production of light nuclei and intermediate mass fragments, 3< or =Z< or =24, were measured at angles well beyond the grazing angle for /sup 32/S-induced reactions on Ag at 720 MeV. Information about fragment multiplicities and reaction dynamics was extracted from measurements of light particles, intermediate mass fragments, and targetlike residues in coincidence with intermediate mass fragments. Incomplete linear momentum transfer and non-compound-particle emission are important features of collisions producing intermediate mass fragments. About half of the incident kinetic energy in these collisions is converted into internal excitation. The mean multiplicity of intermediate mass fragments is of the order of 1. Particle correlations are strongly enhanced in the plane which contains the intermediate mass fragment and the beam axis

  9. Performance of A Compact Multi-crystal High-purity Germanium Detector Array for Measuring Coincident Gamma-ray Emissions

    Energy Technology Data Exchange (ETDEWEB)

    Howard, Chris [Univ. of North Carolina, Chapel Hill, NC (United States); Triangle Univ. Nuclear Lab., Durham, NC (United States); Daigle, Stephen [Univ. of North Carolina, Chapel Hill, NC (United States); Triangle Univ. Nuclear Lab., Durham, NC (United States); Buckner, Matt [Univ. of North Carolina, Chapel Hill, NC (United States); Triangle Univ. Nuclear Lab., Durham, NC (United States); Erikson, Luke E. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Runkle, Robert C. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Stave, Sean C. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Champagne, Art [Univ. of North Carolina, Chapel Hill, NC (United States); Triangle Univ. Nuclear Lab., Durham, NC (United States); Cooper, Andrew [Univ. of North Carolina, Chapel Hill, NC (United States); Triangle Univ. Nuclear Lab., Durham, NC (United States); Downen, Lori [Univ. of North Carolina, Chapel Hill, NC (United States); Triangle Univ. Nuclear Lab., Durham, NC (United States); Glasgow, Brian D. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Kelly, Keegan [Univ. of North Carolina, Chapel Hill, NC (United States); Triangle Univ. Nuclear Lab., Durham, NC (United States); Sallaska, Anne [Univ. of North Carolina, Chapel Hill, NC (United States); Triangle Univ. Nuclear Lab., Durham, NC (United States)

    2015-02-18

    The Multi-sensor Airborne Radiation Survey (MARS) detector is a 14-crystal array of high-purity germanium (HPGe) detectors housed in a single cryostat. The array was used to measure the astrophysical S-factor for the 14N(p,γ)15O* reaction for several transition energies at an effective center of mass energy of 163 keV. Owing to the segmented nature of the MARS detector, the effect of gamma-ray summing was greatly reduced in comparison to past experiments which utilized large, single-crystal detectors. The new S-factor values agree within the uncertainties with the past measurements. Details of the analysis and detector performance will be presented.

  10. Performance of a compact multi-crystal high-purity germanium detector array for measuring coincident gamma-ray emissions

    Energy Technology Data Exchange (ETDEWEB)

    Howard, Chris; Daigle, Stephen; Buckner, Matt [University of North Carolina at Chapel Hill, Chapel Hill, NC 27599 (United States); Triangle Universities Nuclear Laboratory, Durham, NC 27708 (United States); Erikson, Luke E.; Runkle, Robert C. [Pacific Northwest National Laboratory, Richland, WA 99352 (United States); Stave, Sean C., E-mail: Sean.Stave@pnnl.gov [Pacific Northwest National Laboratory, Richland, WA 99352 (United States); Champagne, Arthur E.; Cooper, Andrew; Downen, Lori [University of North Carolina at Chapel Hill, Chapel Hill, NC 27599 (United States); Triangle Universities Nuclear Laboratory, Durham, NC 27708 (United States); Glasgow, Brian D. [Pacific Northwest National Laboratory, Richland, WA 99352 (United States); Kelly, Keegan; Sallaska, Anne [University of North Carolina at Chapel Hill, Chapel Hill, NC 27599 (United States); Triangle Universities Nuclear Laboratory, Durham, NC 27708 (United States)

    2015-05-21

    The Multi-sensor Airborne Radiation Survey (MARS) detector is a 14-crystal array of high-purity germanium (HPGe) detectors housed in a single cryostat. The array was used to measure the astrophysical S-factor for the {sup 14}N(p,γ){sup 15}O{sup ⁎} reaction for several transition energies at an effective center-of-mass energy of 163 keV. Owing to the granular nature of the MARS detector, the effect of gamma-ray summing was greatly reduced in comparison to past experiments which utilized large, single-crystal detectors. The new S-factor values agree within their uncertainties with the past measurements. Details of the analysis and detector performance are presented.

  11. A coincidence measurement of the D(gamma, pp pi(-)) cross section in the region of the Delta resonance

    Science.gov (United States)

    Quraan, Maher A.

    Photonuclear reactions are excellent means for understanding final state interactions (FSI). The photon interacts only electromagnetically, allowing a clean separation of the strong interaction channels in the final state. The availability of high duty factor electron machines and large acceptance detectors in the past decade have allowed a further investigation of these effects covering wider regions of phase space. In this experiment, we have successfully measured the D(/gamma, pp/pi/sp-) reaction cross section at the Saskatchewan Accelerator Laboratory (SAL) utilizing the Saskatchewan- Alberta Large Acceptance Detector (SALAD). This is the first measurement of the /gamma D /to pp/pi/sp--cross section covering a wide range of phase space with an attempt to study the FSI's and the /Delta - N interaction that has successfully reproduced the normalizations. The cross section for this reaction is compared to the calculation of J. M. Laget. Laget's theory is quite successful in describing the shapes of the distributions. as well as the overall magnitude of the cross section. The different FSI's and the /Delta - N interaction have an overall effect of 10%-15% on the single differential cross section, with the calculation that includes /Delta - N interaction having the best normalization compared to the data.

  12. Integrated coincidence circuits

    International Nuclear Information System (INIS)

    Borejko, V.F.; Grebenyuk, V.M.; Zinov, V.G.

    1976-01-01

    The description is given of two coincidence units employing integral circuits in the VISHNYA standard. The units are distinguished for the coincidence selection element which is essentially a combination of a tunnel diode and microcircuits. The output fast response of the units is at least 90 MHz in the mode of the output signal unshaped in duration and 50 MHz minimum in the mode of the output signal shaping. The resolution time of the units is dependent upon the duration of input signals

  13. The determination of electron momentum densities by inelastic scattering gamma-ray-electron coincidence measurements: The (γ,eγ)-experiment

    International Nuclear Information System (INIS)

    Rollason, A.J.; Bell, F.; Schneider, J.R.

    1989-09-01

    Measurements have been made of the recoiling electron in 320 keV gamma ray inelastic scattering collisions in thin aluminium targets. The angular correlation of these electrons detected in coincidence with the scattered photon is in agreement with the kinematic requirements of the Compton effect and is correctly predicted by Monte Carlo simulations based on the impulse approximation. Further simulations of ideal-geometry experiments indicate that information about the initial electron momenta is available from an examination of those electron-photon events originating in a surface layer of one electronic mean free path depth and that elastic scattering of the recoil electrons from greater depths produces a nearly flat background to this signal. The results clearly demonstrate the feasibility of the (γ,eγ) experiment for studying electron momentum densities with synchrotron radiation. (orig.) With 23 refs., 17 figs

  14. Development of portable Liquid Scintillation counters for on-site primary measurement of radionuclides using the Triple-to-Double Coincidence Ratio method

    International Nuclear Information System (INIS)

    Cassette, P.; Capogni, M.; De Felice, P.; Johansson, L.; Sephton, J.; Kossert, K.; Naehle, O.

    2013-06-01

    The Triple-to-Double Coincidence Ratio (TDCR) method in Liquid Scintillation counting (LSC) is a primary radionuclide standardization method widely used in National Metrology laboratories and was primarily developed for the activity measurement of beta emitters. It is based on liquid scintillation: the light is detected by three photomultipliers (PM) and the detection efficiency is evaluated by using a model which uses the ratio of triple-to-double coincidences between the PM tubes. Up to now, most of current TDCR systems were locally-made metrology instruments neither aimed at nor suitable for in-situ measurements. In the framework of the European Metrofission project, a work package was dedicated to the realisation of miniature self-calibrated primary TDCR systems, which are state-of-the-art, for use on-site. The challenge was to develop a versatile portable, table-top designed instrument, from this metrology device. This implied improvements for the miniaturisation of the detection chamber, for the miniaturisation of electronic modules by exploring the possibilities of digital treatment, and for the validation of models and extension of them to nuclides with special beta spectrum shapes, to nuclides with complex decay schemes including many gamma-rays and to nuclides with higher atomic number decaying by electron capture. Four prototypes of counters were built by the Metrofission partners ENEA (Italy), LNHB (France), NPL (UK) and PTB (Germany) using various technical approaches. The paper describes these prototypes and provides some details on the choice of the technical options concerning the design of the optical chamber, of the photodetectors and of the acquisition system. (authors)

  15. Photoion spectroscopy of atoms using coincidence techniques

    International Nuclear Information System (INIS)

    Hayaishi, Tatsuji

    1990-01-01

    Interaction of atoms or molecules with photons causes many effects which are often obscured because of many decay paths from the event. To pick up an effect in the mixed-up ones, it is necessary to observe the decay path arising the effect alone. There is a coincidence technique in one of experimental means for the purpose of observing the decay path. In this article, two coincidence measurements are presented; a photoelectron-photoion coincidence technique and a threshold photoelectron-photoion coincidence technique. Furthermore, experimental facts of rare gases atoms obtained by the techniques are reviewed. (author)

  16. Measurement of cone beam CT coincidence with megavoltage isocentre and image sharpness using the QUASAR(TM) Penta-Guide phantom

    International Nuclear Information System (INIS)

    Sykes, J R; Lindsay, R; Dean, C J; Thwaites, D I; Brettle, D S; Magee, D R

    2008-01-01

    For image-guided radiotherapy (IGRT) systems based on cone beam CT (CBCT) integrated into a linear accelerator, the reproducible alignment of imager to x-ray source is critical to the registration of both the x-ray-volumetric image with the megavoltage (MV) beam isocentre and image sharpness. An enhanced method of determining the CBCT to MV isocentre alignment using the QUASAR(TM) Penta-Guide phantom was developed which improved both precision and accuracy. This was benchmarked against our existing method which used software and a ball-bearing (BB) phantom provided by Elekta. Additionally, a method of measuring an image sharpness metric (MTF 50 ) from the edge response function of a spherical air cavity within the Penta-Guide phantom was developed and its sensitivity was tested by simulating misalignments of the kV imager. Reproducibility testing of the enhanced Penta-Guide method demonstrated a systematic error of 50 for five measurements was 0.278 ± 0.004 lp mm -1 with no applied misalignment. Simulated misalignments exhibited a clear peak in the MTF 50 enabling misalignments greater than 0.4 mm to be detected. The Penta-Guide phantom can be used to precisely measure CBCT-MV coincidence and image sharpness on CBCT-IGRT systems

  17. A β - γ coincidence

    International Nuclear Information System (INIS)

    Agullo, F.

    1960-01-01

    A β - γ coincidence method for absolute counting is given. The fundamental principles are revised and the experimental part is detailed. The results from 1 98 Au irradiated in the JEN 1 Swimming pool reactor are given. The maximal accuracy is 1 per cent. (Author) 11 refs

  18. Auger decay of 1σg and 1σu hole states of the N2 molecule: Disentangling decay routes from coincidence measurements

    International Nuclear Information System (INIS)

    Semenov, S. K.; Schoeffler, M. S.; Titze, J.; Petridis, N.; Jahnke, T.; Cole, K.; Schmidt, L. Ph. H.; Czasch, A.; Jagutzki, O.; Schmidt-Boecking, H.; Doerner, R.; Akoury, D.; Williams, J. B.; Landers, A. L.; Osipov, T.; Lee, S.; Prior, M. H.; Belkacem, A.; Weber, Th.; Cherepkov, N. A.

    2010-01-01

    Results of the most sophisticated measurements in coincidence with the angular-resolved K-shell photoelectrons and Auger electrons and with two atomic ions produced by dissociation of N 2 molecule are analyzed. Detection of photoelectrons at certain angles makes it possible to separate the Auger decay processes of the 1σ g and 1σ u core-hole states. The Auger electron angular distributions for each of these hole states are measured as a function of the kinetic-energy release of two atomic ions and are compared with the corresponding theoretical angular distributions. From that comparison one can disentangle the contributions of different repulsive doubly charged molecular ion states to the Auger decay. Different kinetic-energy-release values are directly related to the different internuclear distances. In this way one can trace experimentally the behavior of the potential energy curves of dicationic final states inside the Frank-Condon region. Presentation of the Auger-electron angular distributions as a function of kinetic-energy release of two atomic ions opens a new dimension in the study of Auger decay.

  19. Abdominal fat-evaluation by use of single scan computed tomography; Computertomographische Bestimmung des intraabdominellen Fettvolumens mittels Einschicht-Messung

    Energy Technology Data Exchange (ETDEWEB)

    Jacobi, V. [Klinikum der Johann-Wolfgang-Goethe-Univ., Frankfurt am Main (Germany). Inst. fuer Allgemeine Roentgendiagnostik; Steinkamp, M. [Klinikum der Johann-Wolfgang-Goethe-Univ., Frankfurt am Main (Germany). Inst. fuer Allgemeine Roentgendiagnostik; Kirchner, J. [Klinikum der Johann-Wolfgang-Goethe-Univ., Frankfurt am Main (Germany). Inst. fuer Allgemeine Roentgendiagnostik; Fischer, H. [Klinikum der Johann-Wolfgang-Goethe-Univ., Frankfurt am Main (Germany). 2. Medizinische Klinik; Diedrich, C.F. [Klinikum der Johann-Wolfgang-Goethe-Univ., Frankfurt am Main (Germany). 2. Medizinische Klinik; Kollath, J. [Klinikum der Johann-Wolfgang-Goethe-Univ., Frankfurt am Main (Germany). 2. Medizinische Klinik

    1997-02-01

    Purpose: Several studies emphasised the importance of the relationship between intraabdominal and total body adipose tissue as a risk factor for the development of metabolic or cardiovascular diseases. Therefore, the aim of the present study was to examine whether a single scan computed tomography is able to determine the whole intraabdominal fat volume with high accuracy and reproducibility. Materials and methods: Regions of interests (ROIs) were drawn manually for measuring intraabdominal fat in 51 unsuspicious abdominal CT. Results: The sexual differentiation of adipose tissue already described in a lot of studies could be confirmed in this study. Fat still predominates in females in lower half of the body (gynoid obesity). In men it predominates in the upper half (android obesity). Significant correlation concerning measuring the whole intraabdominal fat volume could be found in L1-level in women (r=0.992) and in L2-level in men (r=0.992). Measurement of a single scan enables us to assess whole intraabdominal fat volume due to a special formula. Conclusion: The determination of intraabdominal fat measured by a single scan computed tomography is a procedure associated with high accuracy and reproducibility. (orig.) [Deutsch] Ziel: Da in zahlreichen Studien hervorgehobene Bedeutung des intraabdominellen Fettgewebes gegenueber dem Gesamtkoerperfett als Risikofaktor fuer die Entwicklung metabolischer und kardiovaskulaerer Erkrankungen fordert ein Verfahren zur annaehernd exakten Bestimmung des intraabdominellen Fettgewebes. Ziel der vorliegenden Studie war zu pruefen, ob mit genuegender Genauigkeit die Verwendung einer Einschicht-Methode einen gezielten Einsatz der Computertomographie ermoeglicht und welche Lokalisation der zu waehlenden Schicht die aussagekraeftigste Messung ermoeglicht. Material und Methode: Anhand von 51 Computertomographien des Abdomens anderer Indikation (Normalbefunde) wurde das gesamte intraabdominelle Fettvolumen semiautomatisch mittels ROI

  20. Digital coincidence counting

    International Nuclear Information System (INIS)

    Buckman, S.M.; Ius, D.

    1996-01-01

    This paper reports on the development of a digital coincidence-counting system which comprises a custom-built data acquisition card and associated PC software. The system has been designed to digitise the pulse-trains from two radiation detectors at a rate of 20 MSamples/s with 12-bit resolution. Through hardware compression of the data, the system can continuously record both individual pulse-shapes and the time intervals between pulses. Software-based circuits are used to process the stored pulse trains. These circuits are constructed simply by linking together icons representing various components such as coincidence mixers, time delays, single-channel analysers, deadtimes and scalers. This system enables a pair of pulse trains to be processed repeatedly using any number of different methods. Some preliminary results are presented in order to demonstrate the versatility and efficiency of this new method. (orig.)

  1. Digital coincidence counting

    Science.gov (United States)

    Buckman, S. M.; Ius, D.

    1996-02-01

    This paper reports on the development of a digital coincidence-counting system which comprises a custom-built data acquisition card and associated PC software. The system has been designed to digitise the pulse-trains from two radiation detectors at a rate of 20 MSamples/s with 12-bit resolution. Through hardware compression of the data, the system can continuously record both individual pulse-shapes and the time intervals between pulses. Software-based circuits are used to process the stored pulse trains. These circuits are constructed simply by linking together icons representing various components such as coincidence mixers, time delays, single-channel analysers, deadtimes and scalers. This system enables a pair of pulse trains to be processed repeatedly using any number of different methods. Some preliminary results are presented in order to demonstrate the versatility and efficiency of this new method.

  2. Prospects in coincidence experiments

    International Nuclear Information System (INIS)

    Laget, J.M.

    1984-01-01

    The sensitivity of virtual photons to the local variations of the charge and magnetization densities is exploited to study the short-range part of the nucleon-nucleon interaction inside the nucleus. The possibility of varying energy, squared mass and longitudinal polarization of the photons independently enables us to disentangle the mechanisms related to the internal structure of the nucleon (e.g. quark interchange) and the contribution due to meson exchange. Coincidence experiments of the type (e,e'N) and (e,e'NN) are performed to suppress the meson contribution to the longitudinal part of the quasi-elastic peak. Four typical examples of coincidence experiments induced by virtual photons are discussed: experiments (1) on the spectroscopic structure of the quasi-elastic peak and the problem of deep lying hole states; (2) on the structure of the continuum; (3) on the low energy side of the quasi-elastic peak; and finally a three-arm coincidence experiment. (Auth.)

  3. Measurement of the dead time of a G.M. counter and of the secondary emission of the cathode by the method of the delayed coincidences; Mesure du temps mort d'un compteur G.M. et de l'emission secondaire de la cathode par la methode des coincidences retardees

    Energy Technology Data Exchange (ETDEWEB)

    Picard, E; Rogozinski, A [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1953-07-01

    The dead time of a G.M counter is measured with the method of delayed coincidences. The pulses of the counter that supplies the circuit of coincidences, arrive there, on the one hand, directly, and in the other part, after a known and variable delay. This method permits besides, to study the parasitic impulses coming from the impact of the positive ions on the cathode of the meter. From the results relative to several counters working in various conditions are given. (author) [French] Le temps mort d'un compteur G.M. est mesure a l'aide d'un methode de coincidences retardees. Les impulsions du compteur qui alimentent le circuit de coincidences, y parviennent, d'une part, directement, et, dautre part, apres un retard connu et variable. Cette methode permet de plus, d'etudier les impulsions parasites provenant de l'impact des ions positifs sur la cathode du compteur. Des resultats relatifs a plusieurs compteurs fonctionnant dans des conditions diverses sont donnes. (auteur)

  4. Sensitivity to coincidences and paranormal belief.

    Science.gov (United States)

    Hadlaczky, Gergö; Westerlund, Joakim

    2011-12-01

    Often it is difficult to find a natural explanation as to why a surprising coincidence occurs. In attempting to find one, people may be inclined to accept paranormal explanations. The objective of this study was to investigate whether people with a lower threshold for being surprised by coincidences have a greater propensity to become believers compared to those with a higher threshold. Participants were exposed to artificial coincidences, which were formally defined as less or more probable, and were asked to provide remarkability ratings. Paranormal belief was measured by the Australian Sheep-Goat Scale. An analysis of the remarkability ratings revealed a significant interaction effect between Sheep-Goat score and type of coincidence, suggesting that people with lower thresholds of surprise, when experiencing coincidences, harbor higher paranormal belief than those with a higher threshold. The theoretical aspects of these findings were discussed.

  5. The use of computed neutron coincidence counting with time interval analysis for the analysis of Fork-measurements on a fresh MOX-LWR fuel assembly under water

    Energy Technology Data Exchange (ETDEWEB)

    Baeten, P.; Bruggeman, M.; Carchon, R

    1998-06-01

    The objective of this study was to investigate the influence of different important parameters on measurement results for various fork-detectors. Computed Neutron Coincidence Counting (CNCC) with Time Interval Analysis (TIA) was used for this study. The performance of the electronics for the different fork-detectors was studied by investigating the deadtime perturbed zone of the Rossi-alpha distribution in TIA. The measurement revealed anomalies in the performance of the electronics of the IAEA BWR and LANL fork-detector. The IAEA PWR fork-detector functioned well and the deadtime parameter was calculated. The optimal setting for the pre delay was investigated and it was found that a pre delay of 10 micro seconds should be considered as an optimum between excluding from analysis data in the deadtime perturbed zone and keeping a high signal-to-noise ratio. For the shift register electronics used with the fork-detectors, a pre delay of only 4.5 micro seconds was used. The study of the pre delay and the deadtime showed that the calculated triples-rate is strongly dependent on these parameters. An accurate determination of the triple-rate in this type of measurements has proven to be quite difficult and requires proper operation of the electronics, a correct pre delay and an accurate deadtime correction formalism. By varying the boron concentration in water, the change of the decay time of the Rossi-alpha distribution was clearly observed. This change is due to the variation of the thermal multiplication. The variation of this decay time with the boron concentration proves that Boehnel's model for fast neutron multiplication is not valid under these measurement conditions and that a model for fast and thermal multiplication should be used in order to obtain unbiased measurement results. CNCC with TIA has proved to be a valuable tool in which parameter settings can be varied a posterori and the optimal setting can be determined for each measurement. Moreover, the

  6. The use of computed neutron coincidence counting with time interval analysis for the analysis of Fork-measurements on a fresh MOX-LWR fuel assembly under water

    International Nuclear Information System (INIS)

    Baeten, P.; Bruggeman, M.; Carchon, R.

    1998-06-01

    The objective of this study was to investigate the influence of different important parameters on measurement results for various fork-detectors. Computed Neutron Coincidence Counting (CNCC) with Time Interval Analysis (TIA) was used for this study. The performance of the electronics for the different fork-detectors was studied by investigating the deadtime perturbed zone of the Rossi-alpha distribution in TIA. The measurement revealed anomalies in the performance of the electronics of the IAEA BWR and LANL fork-detector. The IAEA PWR fork-detector functioned well and the deadtime parameter was calculated. The optimal setting for the pre delay was investigated and it was found that a pre delay of 10 micro seconds should be considered as an optimum between excluding from analysis data in the deadtime perturbed zone and keeping a high signal-to-noise ratio. For the shift register electronics used with the fork-detectors, a pre delay of only 4.5 micro seconds was used. The study of the pre delay and the deadtime showed that the calculated triples-rate is strongly dependent on these parameters. An accurate determination of the triple-rate in this type of measurements has proven to be quite difficult and requires proper operation of the electronics, a correct pre delay and an accurate deadtime correction formalism. By varying the boron concentration in water, the change of the decay time of the Rossi-alpha distribution was clearly observed. This change is due to the variation of the thermal multiplication. The variation of this decay time with the boron concentration proves that Boehnel's model for fast neutron multiplication is not valid under these measurement conditions and that a model for fast and thermal multiplication should be used in order to obtain unbiased measurement results. CNCC with TIA has proved to be a valuable tool in which parameter settings can be varied a posterori and the optimal setting can be determined for each measurement. Moreover, the

  7. Design and manufacture of a three-counter channel system based on delayed coincidence principle using for 22'3Ra and 224Ra measurements

    International Nuclear Information System (INIS)

    Tuong Thi Thu Huong; Pham Ngoc Tuan; Dang Hong Ngoc Quy; Truong Van Dat; Tran Anh Khoi; Chau Thi Nhu Quynh

    2016-01-01

    The research group has designed and fabricated a radiation detection system for measuring low activities of 223 Ra and 224 Ra in natural waters based on a design of Giffin et al (1963). Samples are obtained by adsorbing 223 Ra and 224 Ra onto a column of MnO 2 coated fiber (Mn fiber). The short-lived Rn daughters of 223 Ra and 224 Ra which recoil from the Mn fiber are swept into a scintillation detector where alpha decays of Rn and Po occur. Signals from the detector are sent to a delayed coincidence circuit which discriminates decay of the 224 Ra daughters, 220 Ra and 216 Po, from decays of the 223 Ra daughters, 219 Ra and 215 Po. The main product of this project is a “Low Alpha counting system” based on digital technology. This system consists of some main electronic circuit such as amplifier, single channel analyzer, counters/timers, micro-processor, RS232 interfacing. Almost of mentioned-above components have been designed and fabricated using ISE 10.1 software toolkits from Xilinx. The application program for controlling and collecting data from the device is written in LabView. In comparison with conventional analog circuits, the design of this system is smaller and easy to use owing to being connected to personal computer through RS232 interface in order to data acquisition and processing. This is also a new trend in the field of development of nuclear equipment with the aim to simple design, cost-saving (Reuse of hardware components can further reduce the system development cost), flexible (arbitrarily adjust measurement parameters by setting parameters from software), user-Friendly Environment (program directly embedded into the FPGA). (author)

  8. Coincidence corrections for a multi-detector gamma spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Britton, R., E-mail: r.britton@surrey.ac.uk [University of Surrey, Guildford GU2 7XH (United Kingdom); AWE, Aldermaston, Reading, Berkshire RG7 4PR (United Kingdom); Burnett, J.L.; Davies, A.V. [AWE, Aldermaston, Reading, Berkshire RG7 4PR (United Kingdom); Regan, P.H. [University of Surrey, Guildford GU2 7XH (United Kingdom)

    2015-01-01

    List-mode data acquisition has been utilised in conjunction with a high-efficiency γ–γ coincidence system, allowing both the energetic and temporal information to be retained for each recorded event. Collected data is re-processed multiple times to extract any coincidence information from the γ-spectroscopy system, correct for the time-walk of low-energy events, and remove accidental coincidences from the projected coincidence spectra. The time-walk correction has resulted in a reduction in the width of the coincidence delay gate of 18.4±0.4%, and thus an equivalent removal of ‘background’ coincidences. The correction factors applied to ∼5.6% of events up to ∼500 keV for a combined {sup 137}Cs and {sup 60}Co source, and are crucial for accurate coincidence measurements of low-energy events that may otherwise be missed by a standard delay gate. By extracting both the delay gate and a representative ‘background’ region for the coincidences, a coincidence background subtracted spectrum is projected from the coincidence matrix, which effectively removes ∼100% of the accidental coincidences (up to 16.6±0.7% of the total coincidence events seen during this work). This accidental-coincidence removal is crucial for accurate characterisation of the events seen in coincidence systems, as without this correction false coincidence signatures may be incorrectly interpreted.

  9. Experimental determination of the dynamic properties of screw compressors; Die experimentelle Bestimmung der dynamischen Eigenschaften von Schraubenkompressoren

    Energy Technology Data Exchange (ETDEWEB)

    Rinder, L. [Technische Univ., Wien (Austria). Abt. Maschinenelemente; Svigler, J.; Pasek, M.; Albl, P. [Westboehmische Univ., Pilsen (Czech Republic). Lehrstuhl fuer Mechanik

    1998-12-31

    The demand for continuing improvements of screw machines leads to a vibration research of these machines. The presented paper deals with the experimental measurement of screw compressor operational vibrations and the determination of vibration sources. The measuring of operational vibrations, modal analysis and the determination of mode shape forms of a screw compressor were performed. The main sources of the operational vibrations were determined and the screw compressor eigenfrequencies were found in the frequency spectrum. This contribution forms a basis for the comparison of the theoretical and experimental results. This work was done in cooperation between the University of West Bohemia Pilsen and the Technical University Vienna. (orig.) [Deutsch] Staendig steigende Anforderungen an die Laufruhe von Schraubenkompressoren machen Schwingungsuntersuchungen an diesen Maschinen notwendig. Die vorliegende Arbeit beschreibt Messungen des Betriebs-Schwingungszustandes und die Bestimmung der Erregerquellen an einem oeleingespritzten Schraubenverdichter. Es wird der Schwingungszustand mit Beschleunigungsaufnehmern gemessen, eine Modalanalyse beider Rotoren durchgefuehrt und es werden die Eigenformen der Laeufer bestimmt. Die Haupterregerquellen fuer die Schwingungen koennen ermittelt werden. Die Eigenfrequenzen des Kompressors sind im Frequenzspektrum festzustellen. Die Ergebnisse dienen als Basis fuer den Vergleich zwischen experimenteller Schwingungsanalyse und theoretischen Schwingungsuntersuchungen. Ueber theoretische Ergebnisse soll in naechster Zukunft berichtet werden. Die Arbeit entstand im Rahmen einer Zusammenarbeit zwischen der Westboehmischen Universitaet Pilsen und der Technischen Universitaet Wien. Die Schwingungsmessungen wurden am Schraubenverdichterpruefstand des Instituts fuer Maschinenelemente der TU Wien durchgefuehrt. (orig.)

  10. Surface-site-selective study of valence electronic states of a clean Si(111)-7x7 surface using Si L23VV Auger electron and Si 2p photoelectron coincidence measurements

    International Nuclear Information System (INIS)

    Kakiuchi, Takuhiro; Tahara, Masashi; Nagaoka, Shin-ichi; Hashimoto, Shogo; Fujita, Narihiko; Tanaka, Masatoshi; Mase, Kazuhiko

    2011-01-01

    Valence electronic states of a clean Si(111)-7x7 surface are investigated in a surface-site-selective way using high-resolution coincidence measurements of Si pVV Auger electrons and Si 2p photoelectrons. The Si L 23 VV Auger electron spectra measured in coincidence with energy-selected Si 2p photoelectrons show that the valence band at the highest density of states in the vicinity of the rest atoms is shifted by ∼0.95 eV toward the Fermi level (E F ) relative to that in the vicinity of the pedestal atoms (atoms directly bonded to the adatoms). The valence-band maximum in the vicinity of the rest atoms, on the other hand, is shown to be shifted by ∼0.53 eV toward E F relative to that in the vicinity of the pedestal atoms. The Si 2p photoelectron spectra of Si(111)-7x7 measured in coincidence with energy-selected Si L 23 VV Auger electrons identify the topmost surface components, and suggest that the dimers and the rest atoms are negatively charged while the pedestal atoms are positively charged. Furthermore, the Si 2p-Si L 23 VV photoelectron Auger coincidence spectroscopy directly verifies that the adatom Si 2p component (usually denoted by C 3 ) is correlated with the surface state just below E F (usually denoted by S 1 ), as has been observed in previous angle-resolved photoelectron spectroscopy studies.

  11. Triple-coincidence with automatic chance coincidence correction

    International Nuclear Information System (INIS)

    Chase, R.L.

    1975-05-01

    The chance coincidences in a triple-coincidence circuit are of two types--partially correlated and entirely uncorrelated. Their relative importance depends on source strength and source and detector geometry so that the total chance correction cannot, in general, be calculated. The system described makes use of several delays and straightforward integrated circuit logic to provide independent evaluation of the two components of the chance coincidence rate. (auth)

  12. Coincident photoelectron spectroscopy on superconductors

    International Nuclear Information System (INIS)

    Voss, Stefan

    2011-01-01

    Aim of the performed experiments of this thesis was to attempt to detect Cooper pairs as carriers of the superconducting current directly by means of the photoelectric effect. The method of the coincident photoelectron spectroscopy aims thereby at the detection of two coherently emitted electrons by the interaction with a photon. Because electrostatic analyzers typically cover only a very small spatial angle, which goes along with very low coincidence rates, in connection with this thesis a time-of-flight projection system has been developed, which maps nearly the whole spatial angle on a position-resolving detector. The pulsed light source in form of special synchrotron radiation necessary for the measurement has been adjusted so weak, that only single photons could arrive at the sample. Spectroscoped were beside test measurements on silver layers both a lead monocrystal as representative of the classical BCS superconductors and monocrystalline Bi 2 Sr 2 CaCu 2 O 8 from the family of the high-temperature superconductors. With excitation energies up to 40 eV could be shown that sufficiently smooth and clean surfaces in the superconducting phase exhibit within the resolving power of about 0.5 eV no recognizable differences in comparison to the normally conducting phase. Beside these studies furthermore the simple photoemission at the different samples and especially in the case of the lead crystal is treated, because here no comparable results are known. Thereby the whole momentum space is discussed and the Fermi surface established as three-dimensional model, by means of which the measurement results are discussed. in the theoretical descriptions different models for the Cooper-pair production are presented, whereby to the momentum exchange with the crystal a special role is attributed, because this can only occur in direct excitations via discrete lattice vectors.

  13. Study of a 4{pi}{beta}-{gamma} coincidence system for absolute radionuclide activity measurement using plastic scintillators; Estudo de um sistema de coincidencias 4{pi}{beta}-{gamma} para a medida absoluta de atividade de radionuclideos empregando cintiladores plasticos

    Energy Technology Data Exchange (ETDEWEB)

    Piuvezam Filho, Helio

    2007-07-01

    The present work was intended to study a coincidence system 4{pi}(PS){beta}-{gamma} for absolute activity measurement using plastic scintillators in 4{pi} geometry. Along with experiments on the coincidence system, simulations were also performed applying the Monte Carlo Method, by means of codes PENELOPE and ESQUEMA. These simulations were performed in order to calculate the extrapolation curve of the coincidence system 4{pi}(PS){beta}-{gamma} and compare it to experimental data. A new geometry was proposed to the coincidence system adding up a second photomultiplier tube to the previous system for improving light collection from the plastic scintillator, as this system presented limitations in the minimum detected energy due to the presence of electronic noise and low gain. The results show that an improvement in the signal-to-noise ratio was obtained, as well as in the minimum detected energy. Moreover, there was an increase in the detection efficiency. With these modifications, it is now possible to calibrate radionuclides which emit low energy electrons or X-rays, increasing the number of radionuclides that can be standardized with this type of system.(author)

  14. Coincidence counting corrections for dead time losses and accidental coincidences

    International Nuclear Information System (INIS)

    Wyllie, H.A.

    1987-04-01

    An equation is derived for the calculation of the radioactivity of a source from the results of coincidence counting taking into account the dead-time losses and accidental coincidences. The derivation is an extension of the method of J. Bryant [Int. J. Appl. Radiat. Isot., 14:143, 1963]. The improvement on Bryant's formula has been verified by experiment

  15. A practical method for determining γ-ray full-energy peak efficiency considering coincidence-summing and self-absorption corrections for the measurement of environmental samples after the Fukushima reactor accident

    Energy Technology Data Exchange (ETDEWEB)

    Shizuma, Kiyoshi, E-mail: shizuma@hiroshima-u.ac.jp [Graduate School of Engineering, Hiroshima University, Higashi-Hiroshima 739-8527 (Japan); Oba, Yurika; Takada, Momo [Graduate School of Integrated Arts and Sciences, Hiroshima University, Higashi-Hiroshima 739-8521 (Japan)

    2016-09-15

    A method for determining the γ-ray full-energy peak efficiency at positions close to three Ge detectors and at the well port of a well-type detector was developed for measuring environmental volume samples containing {sup 137}Cs, {sup 134}Cs and {sup 40}K. The efficiency was estimated by considering two correction factors: coincidence-summing and self-absorption corrections. The coincidence-summing correction for a cascade transition nuclide was estimated by an experimental method involving measuring a sample at the far and close positions of a detector. The derived coincidence-summing correction factors were compared with those of analytical and Monte Carlo simulation methods and good agreements were obtained. Differences in the matrix of the calibration source and the environmental sample resulted in an increase or decrease of the full-energy peak counts due to the self-absorption of γ-rays in the sample. The correction factor was derived as a function of the densities of several matrix materials. The present method was applied to the measurement of environmental samples and also low-level radioactivity measurements of water samples using the well-type detector.

  16. Particle-gamma coincidence measurements in 12C+12C and 12C+Pb collisions at 2.1 GeV/nucleon incident energy

    International Nuclear Information System (INIS)

    Roche, G.; Koontz, R.; Mulera, T.; Pugh, H.G.; Schroeder, L.S.; Hallman, T.; Madansky, L.; Carroll, J.; Chang, C.C.; Kirk, P.N.; Krebs, G.; Vicente, J.

    1985-01-01

    A particle-gamma coincidence experiment has been performed with a 2.1 GeV per nucleon 12 C beam from the Bevalac. Data were taken with C and Pb targets. The γ-ray spectra are almost independent of the energy or the kind of charged particles detected in coincidence, mainly protons and deuterons. These γ-ray spectra are interpreted as resulting from π 0 decay, and are consistent with known π 0 production rates. A search for a possible decay of singly-charged anomalons into a gamma and a deuteron (or unbound proton-neutron system) has been done by studying the γp and γd invariant mass distributions. The upper limits for such a process are found to be 2 to 20% of the deuteron production rate, for anomalon masses for 200 to 400 MeV above the deuteron mass, with an anomalon mean lifetime of up to 10 -9 s, depending on which kind of decay process is considered. (orig.)

  17. Coincidence method for determination of radionuclides activities

    International Nuclear Information System (INIS)

    Andrukhovich, S.K.; Berestov, A.V.; Rudak, E.A.

    2004-01-01

    The radon and radium activity measurements using six-crystal gamma-gamma coincidence, 4 -spectrometer PRIPJAT and radioactivity measurements in different samples of meat and vegetation by 32-crystal spectrometer ARGUS, are described. Radiation detector with 4 -geometry provides higher efficiency, and therefore shorter counting time than a detector without such geometry. However, its application is limited by the fact that obtained spectrum contains summing peaks of all γ-quanta registered in coincidence. Multiparameter information on coincident photon emission can be obtained only by a detection system where the 4 -geometry is made by many detectors, such are both the PRIPJAT and the ARGUS - γ-coincidence spectrometer of the Crystal Ball type in the Institute of Physics, Minsk [1,2]. There are other characteristics, as background conditions, energy and time resolution, makes it ve suitable for investigation of rare decays and interactions, cascade transitions, k intensity radiations etc. We are developing a method of 2 26R a and 2 26 Rn measurement by a multidetector 4 -spectrometer. The method is based on coincidence counting of γ-rays from two step cascade transitions that follow - decay of 2 14 Bi. Its application to the PRIPL spectrometer, which has 6 Nal(Tl) detectors, is presented here, as well as the method of the determination of radionuclide activities based on the registration of the cascades intensity of γ-rays of different multiplicity using ARGUS

  18. A portable neutron coincidence counter

    Energy Technology Data Exchange (ETDEWEB)

    Peurrung, A.J.; Bowyer, S.M.; Craig, R.A.; Dudder, G.B.; Knopf, M.A.; Panisko, M.E.; Reeder, P.L.; Stromswold, D.C.; Sunberg, D.S.

    1996-11-01

    Pacific Northwest National Laboratory has designed and constructed a prototype portable neutron coincidence counter intended for use in a variety of applications, such as the verification and inspection of weapons components, safety measurements for novel and challenging situations, portable portal deployment to prevent the transportation of fissile materials, uranium enrichment measurements in hard-to-reach locations, waste assays for objects that cannot be measured by existing measurement systems, and decontamination and decommissioning. The counting system weighs less than 40 kg and is composed of parts each weighing no more than 5 kg. In addition, the counter`s design is sufficiently flexible to allow rapid, reliable assembly around containers of nearly arbitrary size and shape. The counter is able to discern the presence of 1 kg of weapons-grade plutonium within an ALR-8 (30-gal drum) in roughly 100 seconds and 10 g in roughly 1000 seconds. The counter`s electronics are also designed for maximum adaptability, allowing operation under a wide variety of circumstances, including exposure to gamma-ray fields of 1 R/h. This report provides a detailed review of the design and construction process. Finally, preliminary experimental measurements that confirm the performance capabilities of this counter are discussed. 6 refs., 18 figs., 3 tabs.

  19. Total cross-section measurements on aluminium, carbon, fluorine and hydrogen for d, d reaction neutrons using the coincidence method (1963); Mesure de la section efficace totale de l'aluminium, du carbone, du fluor et de l'hydrogene pour des neutrons de la reaction d, d par la methode des coincidences (1963)

    Energy Technology Data Exchange (ETDEWEB)

    Ambrosino, G; Sorriaux, A [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1964-07-01

    The experiment described consists in the measurement of the total cross-section of various materials: aluminium, carbon, fluorine and hydrogen, for mono-energetic 2.77 MeV neutrons obtained from the d,d reaction. The measurement is carried out by transmission. The neutrons are detected by means of a plastic scintillator mounted on a 56 AVP photomultiplier, and are isolated from all secondary phenomena (background noise, scattered neutrons) by coincidence with helium 3. which particles are associated to the neutrons from the reaction {sup 2}{sub 1}D ({sup 2}{sub 1}D, n) {sup 3}{sub 2}H The helium 3 particles are detected by a PN junction diode used with inverted polarisation. An absorption exponential has been traced out using measurements made on seven aluminium bars. The accuracy of the total cross-section measurements is about 10{sup -2}. (authors) [French] L'experience exposee dans ce rapport consiste en la mesure des sections efficaces totales de differents materiaux: aluminium, carbone, fluor et hydrogene, pour des neutrons monoenergetiques de 2,77 MeV, obtenus par la reaction d,d. La mesure est faite par transmission. Les neutrons sont detectes par un scintillateur plastique monte sur un photomultiplicateur 56 AVP, et sont separes de tout phenomene secondaire (bruit de fond, neutrons diffuses) par coincidence avec les helium 3, particules associees aux neutrons de la reaction {sup 2}{sub 1}D ({sup 2}{sub 1}D, n) {sup 3}{sub 2}H Les helium 3 sont detectes par une diode a jonction PN utilisee en polarisation inverse. Une exponentielle d'absorption a ete tracee a partir de mesures faites sur sept barreaux d'aluminium. La precision des mesures des sections efficaces totales est de l'ordre de 10{sup -2}. (auteurs)

  20. Determination of the analyzing power of the A4 Compton-backscattering polarimeter for the measurement of the longitudinal spin polarization of the MAMI electron beam; Bestimmung der Analysierstaerke des A4-Compton-Rueckstreupolarimeters zur Messung der longitudinalen Spinpolarisation des MAMI-Elektronenstrahls

    Energy Technology Data Exchange (ETDEWEB)

    Diefenbacher, Juergen

    2010-08-22

    The A4 experiment determines the strange quark contribution to the electromagnetic from factors of the nucleon by measuring the parity violation in elastic electron nucleon scattering. These measurements are carried out using the spin polarized electron beam of the Mainzer Mikrotron (MAMI) with beam energies in the range from 315 to 1508 MeV. For the data analysis it is essential to determine the degree of polarization of the electron beam in order to extract the physics asymmetry from the measured parity violating asymmetry. For this reason the A4 collaboration has developed a novel type of Compton laser backscattering polarimeter that allows for a non-destructive measurement of the beam polarization in parallel to the running parity experiment. In the scope of this work the polarimeter was refined in order to enable reliable continuous operation of the polarimeter. The data acquisition system for the photon and electron detector was re-designed and optimized to cope with high count rates. A novel detector (LYSO) for the backscattered photons was commissioned. Furthermore, GEANT4 simulations of the detectors have been performed and an analysis environment for the extraction of Compton asymmetries from the backscattered photon data has been developed. The analysis makes use of the possibility to detect backscattered photons in coincidence with the scattered electrons, thus tagging the photons. The tagging introduces a differential energy scale which enables the precise determination of the analyzing power. In this work the analyzing power of the polarimeter has been determined. Therefore, at a beam current of 20 {mu}A the product of electron and laser polarization can be determined, while the parity experiment is running, with a statistical accuracy of 1 % in 24 hours at 855 MeV or <1 % in 12 hours at 1508 MeV. Combining this with the determination of the laser polarization carried out in parallel work (Y. Imai), the uncertainty of the electron beam polarization in

  1. Determination of benzene in exhaust gas from biofuels. Final report; Bestimmung von Benzol im Abgas von Biokraftstoffen. Abschlussbericht

    Energy Technology Data Exchange (ETDEWEB)

    Dutz, M.; Buenger, J.; Gnuschke, H.; Halboth, H.; Gruedl, P.; Krahl, J.

    2001-10-01

    With the advance of environmental legislation and practices oriented towards sustainability renewable energy resources are becoming increasingly important. Use of replenishable raw materials helps preserve fossil resources. In the fuel sector the most widely used replenishable materials are rape methyl ester (RME) and ethyl tertiary butyl ether (ETBE). The purpose of the present project on the ''Determination of benzene in exhaust gas from biofuels'' was to generate orienting data on the potential health relevance of mixtures of fossil and renewable fuel intended for use in spark ignition and diesel engines. This included a determination of benzene emissions and the mutagenicity of particles. Beyond the applied-for scope of research measurements were also performed on the test engine's toluene, ethyl benzene and xylene emissions as well as on the smoke spot number and nitrogen oxide (NO{sub x}) and hydrocarbon (HC) emissions of the diesel engine. [German] Regenerative Energien gewinnen durch die Umweltgesetzgebungen und das Streben nach einer nachhaltigen Entwicklung zunehmend an Bedeutung. Durch die Verwendung nachwachsender Rohstoffe koennen die fossilen Ressourcen geschont werden. Im Kraftstoffsektor sind hier hauptsaechlich Rapsoelmethylester (RME) und optional Ethyltertiaerbutylether (ETBE) zu nennen. Um fuer Diesel- und Ottomotoren insbesondere mit Blick auf Kraftstoffgemische aus fossilen und regenerativen Komponenten orientierende Daten ueber eine potenzielle Gesundheitsrelevanz zu generieren, wurde das Projekt 'Bestimmung von Benzol im Abgas von Biokraftstoffen' durchgefuehrt. Neben der Benzolemission wurde die Mutagenitaet der Partikeln ermittelt. Ueber den beantragten Untersuchungsrahmen hinaus wurden die Tuluol-, Ethylbenzol-, und Xylolemissionen der eingesetzten Motoren, sowie die Russzahl (RZ) und die Stickoxid- (NO{sub x}) und Kohlenwasserstoffemissionen (HC) des Dieselmotors bestimmt. (orig.)

  2. Multiverse understanding of cosmological coincidences

    International Nuclear Information System (INIS)

    Bousso, Raphael; Hall, Lawrence J.; Nomura, Yasunori

    2009-01-01

    There is a deep cosmological mystery: although dependent on very different underlying physics, the time scales of structure formation, of galaxy cooling (both radiatively and against the CMB), and of vacuum domination do not differ by many orders of magnitude, but are all comparable to the present age of the universe. By scanning four landscape parameters simultaneously, we show that this quadruple coincidence is resolved. We assume only that the statistical distribution of parameter values in the multiverse grows towards certain catastrophic boundaries we identify, across which there are drastic regime changes. We find order-of-magnitude predictions for the cosmological constant, the primordial density contrast, the temperature at matter-radiation equality, the typical galaxy mass, and the age of the universe, in terms of the fine structure constant and the electron, proton and Planck masses. Our approach permits a systematic evaluation of measure proposals; with the causal patch measure, we find no runaway of the primordial density contrast and the cosmological constant to large values.

  3. Kinematical coincidence method in transfer reactions

    Energy Technology Data Exchange (ETDEWEB)

    Acosta, L.; Amorini, F. [INFN—Laboratori Nazionali del Sud, Via S. Sofia, Catania (Italy); Auditore, L. [INFN Gruppo Collegato di Messina and Dipartimento di Fisica, Università di Messina (Italy); Berceanu, I. [Institute for Physics and Nuclear Engineering, Bucharest (Romania); Cardella, G., E-mail: cardella@ct.infn.it [INFN—Sezione di Catania, Via S. Sofia, 95123 Catania (Italy); Chatterjiee, M.B. [Saha Institute for Nuclear Physics, Kolkata (India); De Filippo, E. [INFN—Sezione di Catania, Via S. Sofia, 95123 Catania (Italy); Francalanza, L.; Gianì, R. [INFN—Laboratori Nazionali del Sud, Via S. Sofia, Catania (Italy); Dipartimento di Fisica e Astronomia, Università di Catania, Via S. Sofia, Catania (Italy); Grassi, L. [INFN—Sezione di Catania, Via S. Sofia, 95123 Catania (Italy); Rudjer Boskovic Institute, Zagreb (Croatia); Grzeszczuk, A. [Institut of Physics, University of Silesia, Katowice (Poland); La Guidara, E. [INFN—Sezione di Catania, Via S. Sofia, 95123 Catania (Italy); Centro Siciliano di Fisica Nucleare e Struttura della Materia, Catania (Italy); Lanzalone, G. [INFN—Laboratori Nazionali del Sud, Via S. Sofia, Catania (Italy); Facoltà di Ingegneria e Architettura, Università Kore, Enna (Italy); Lombardo, I. [INFN—Laboratori Nazionali del Sud, Via S. Sofia, Catania (Italy); Dipartimento di Scienze Fisiche, Università Federico II and INFN Sezione di Napoli (Italy); Loria, D.; Minniti, T. [INFN Gruppo Collegato di Messina and Dipartimento di Fisica, Università di Messina (Italy); Pagano, E.V. [INFN—Laboratori Nazionali del Sud, Via S. Sofia, Catania (Italy); Dipartimento di Fisica e Astronomia, Università di Catania, Via S. Sofia, Catania (Italy); and others

    2013-07-01

    A new method to extract high resolution angular distributions from kinematical coincidence measurements in binary reactions is presented. Kinematics is used to extract the center of mass angular distribution from the measured energy spectrum of light particles. Results obtained in the case of {sup 10}Be+p→{sup 9}Be+d reaction measured with the CHIMERA detector are shown. An angular resolution of few degrees in the center of mass is obtained. The range of applicability of the method is discussed.

  4. Channel coincidence counter: version 1

    International Nuclear Information System (INIS)

    Krick, M.S.; Menlove, H.O.

    1980-06-01

    A thermal neutron coincidence counter has been designed for the assay of fast critical assembly fuel drawers and plutonium-bearing fuel rods. The principal feature of the detector is a 7-cm by 7-cm by 97-cm detector channel, which provides a uniform neutron detection efficiency of 16% along the central 40 cm of the channel. The electronics system is identical to that used for the High-Level Neutron Coincidence Counter

  5. Reliability of two different methods, whole body measurement and shoulder probe measurement, as judged from determinations of the renal clearance of orthoiodine hippuric acid. Methodenvergleich von Ganzkoerper- und Schultersonden-Messtechnik bei der nuklearmedizinischen Nierenclearance-Bestimmung mit Ortho-Jod-Hippursaeure

    Energy Technology Data Exchange (ETDEWEB)

    Roth, A

    1983-05-06

    This retrospective study was based on 1300 patients subjected to a series of radiopharmaceutical renal function studies, during which parallel determinations of the renal clearance rate were carried out using whole body measurements and shoulder probe measurements. It was the aim of this analysis to assess the reliability of shoulder probe measurements as compared to that of whole body measurements as well as their suitability for the diagnosis of postural perfusion disorders associated with nephroptosis and to define the generally acceptable normal ranges of the clearance of ortho-iodine hippuric acid on the basis of age and sex groups. As long as the values measured remained within normal limits, no major differences were discernable between the two methods. In reduced renal function, however, the shoulder probe measurements were biassed in a consistent way and tended to an overestimation of the renal performance that was proportionate to the degree of insufficiency. The intra-assay variations observed for the two methods did not differ from each other at a statistically significant level. The systematic error seen in connection with the shoulder probe measurements can in fact be easily eliminated. This method also offers the advantage of greater simplicity and can be carried out with the patient being in an upright position. Its suitability for the detection of postural perfusion disorders still remains to be proven in further studies. The results of the study are of clinical relevance inasfar as it was possible to determine lower limits of OJH clearance for the individual age and sex groups.

  6. Bestimmung der Mas'se des neutralen Bs-Mesons mit dem ALEPH-Experiment

    CERN Document Server

    Stehle, M

    2001-01-01

    Gegenstand der vorliegenden Arbeit ist die Bestimmung der Masse des neutralen Bs-Mesons. Dazu wurden B~-Mesonen in den beiden Zerfallskanalen B~ -+ J/W P und B~ -+ W(2S) P rekonstruiert, wobei die Subresonanzen in den Zerfallsmoden J /w -+ l+ l-, W(2S) -+ l+ l- und P -+ K+ K- untersucht wurden. Diese beiden Kanale werden auf Grund ihrer eindeutigen Signatur auch als "goldene Kanale" bezeichnet und eignen sich deshalb sehr gut fur eine exklusive Rekonstruktion, wie sie hier angewendet wurde. Grundlage der Analyse waren ca. 4 Millionen hadronische ZO-Zerfalle, die in den Jahren 1991 1995 mit dem ALEPH-Detektor am e+e--Speicherring LEP am CERN aufgezeichnet wurden. Die zwischenzeitliche Reprozessierung der Daten ermoglichte eine prazisere und effizientere Rekonstruktion als das in fruheren Messungen der Fall war. Wegen der niedrigen Verzweigungsverhaltnisse der untersuchten Zerfallsmoden wurden nur wenige einzelne Ereignisse in den Daten erwartet. Die selektierten Kandidaten wurden durch Schnitte in mehreren Ere...

  7. Development of a minicomputer system for on-line processing of gamma--gamma coincidence events and measurements of E2/M1 mixing ratios in 110Cd and 134Ba

    International Nuclear Information System (INIS)

    Ruhter, W.D.

    1977-12-01

    A megachannel pulse-height analysis system using a 32,000-word PDP-8/E minicomputer and two moving-head disk memories was developed. The system has a storage capacity of 2 18 events at any of 2 20 data locations, is capable of processing 1,040 events/s, and provides on-line sorting and disk storage. An X- or Y- pulse-height spectrum in coincidence with one to four arithmetically combined pulse-height windows can be assembled in core for scope display and spectral analysis within 2 to 20 seconds. The software for the system was written extensively in machine language. Excellent energy and timing resolution were achieved. An energy resolution of 2.3 keV fwhm and a timing resolution of 8.5 ns fwhm were obtained for 60 Co at a singles rate of 10,000 counts/s. The prompt timing peak remained Gaussian down to the fwtm by gating the TAC with SCAs which discriminated against low-energy events. The coincidence electronics also allowed on-line subtraction of accidental coincidence events. Alignment of the detectors and tests of the system's performance were made by measuring solid-angle correction factors for the Ge(Li) detectors through the correlation measurements of the 0 + --2 + --0 + cascade in 106 Pd, and by measuring the angular spread of positron annihilation radiation coincidences. Results were in excellent agreement with theoretical solid-angle correction factors calculated for the detector and source sizes used. Directional correlation data were obtained for gamma-ray cascades in 134 Ba and 110 Cd. Analyses of these data gave E2/M1 mixing ratios which are in excellent agreement with results obtained by other investigators. The improved resolution and data processing capabilities of this system gave new results for the 563-keV transition in 134 Ba and the 1505-keV transition in 110 Cd. E2/M1 mixing ratios of 13.3/sup +2.3/sub -1.8/ for the 563-keV transition and -1.24 +- 0.20 for the 1505-keV transition were measured

  8. Coincident Retrieval of Ocean Surface Roughness and Salinity Using Airborne and Satellite Microwave Radiometry and Reflectometry Measurements during the Carolina Offshore (Caro) Experiment.

    Science.gov (United States)

    Burrage, D. M.; Wesson, J. C.; Wang, D. W.; Garrison, J. L.; Zhang, H.

    2017-12-01

    were assessed, and the coincident buoy, aircraft and satellite retrievals of MSS, WSP and SSS were compared. During Caro WSP from the different instruments generally agreed. Some anomalously high wind retrievals found here and elsewhere in current CYGNSS Level 2 data may yield to the science team's recent L1 calibration revision.

  9. Fast coincidence counting with active inspection systems

    Science.gov (United States)

    Mullens, J. A.; Neal, J. S.; Hausladen, P. A.; Pozzi, S. A.; Mihalczo, J. T.

    2005-12-01

    This paper describes 2nd and 3rd order time coincidence distributions measurements with a GHz processor that synchronously samples 5 or 10 channels of data from radiation detectors near fissile material. On-line, time coincidence distributions are measured between detectors or between detectors and an external stimulating source. Detector-to-detector correlations are useful for passive measurements also. The processor also measures the number of times n pulses occur in a selectable time window and compares this multiplet distribution to a Poisson distribution as a method of determining the occurrence of fission. The detectors respond to radiation emitted in the fission process induced internally by inherent sources or by external sources such as LINACS, DT generators either pulsed or steady state with alpha detectors, etc. Data can be acquired from prompt emission during the source pulse, prompt emissions immediately after the source pulse, or delayed emissions between source pulses. These types of time coincidence measurements (occurring on the time scale of the fission chain multiplication processes for nuclear weapons grade U and Pu) are useful for determining the presence of these fissile materials and quantifying the amount, and are useful for counter terrorism and nuclear material control and accountability. This paper presents the results for a variety of measurements.

  10. Fast coincidence counting with active inspection systems

    International Nuclear Information System (INIS)

    Mullens, J.A.; Neal, J.S.; Hausladen, P.A.; Pozzi, S.A.; Mihalczo, J.T.

    2005-01-01

    This paper describes 2nd and 3rd order time coincidence distributions measurements with a GHz processor that synchronously samples 5 or 10 channels of data from radiation detectors near fissile material. On-line, time coincidence distributions are measured between detectors or between detectors and an external stimulating source. Detector-to-detector correlations are useful for passive measurements also. The processor also measures the number of times n pulses occur in a selectable time window and compares this multiplet distribution to a Poisson distribution as a method of determining the occurrence of fission. The detectors respond to radiation emitted in the fission process induced internally by inherent sources or by external sources such as LINACS, DT generators either pulsed or steady state with alpha detectors, etc. Data can be acquired from prompt emission during the source pulse, prompt emissions immediately after the source pulse, or delayed emissions between source pulses. These types of time coincidence measurements (occurring on the time scale of the fission chain multiplication processes for nuclear weapons grade U and Pu) are useful for determining the presence of these fissile materials and quantifying the amount, and are useful for counter terrorism and nuclear material control and accountability. This paper presents the results for a variety of measurements

  11. Modification of the method of Figgie for determination of joint line shifting in total knee arthroplasty; Modifizierung der Messmethode nach Figgie zur Bestimmung der Gelenklinienverschiebung in der Knieendoprothetik

    Energy Technology Data Exchange (ETDEWEB)

    Classen, T.; Wegner, A.; Knoch, M. von [Universitaet Duisburg-Essen, Klinik fuer Orthopaedie, Essen (Germany)

    2009-06-15

    An important factor for a good result after total knee arthroplasty is the position of the patella in relation to the tibiofemoral joint line. The position of the patella itself is not influenced by arthroplasty, therefore any changes in the position of the tibiofemoral joint line are of special interest. The Figgie method to describe patella height delivers only absolute measurements, which makes it difficult to compare different radiographs. For this reason we developed a new JL/P quotient (JL: distance from the tibial plateau to the tibial tubercle, P: distance from the inferior pole of the patella to the tibial plateau) to enable better comparison. Furthermore, we modified the JL/P quotient and instead of taking the tibial plateau as the reference line, we constructed a tangent on the femoral condyle. With this modification, problems such as tibial inlays of different heights which have to be taken into account in the measurements, the slope of the tibial component or difficult assessment of the tibial joint surface in osteoarthritic knees do not arise. The JL/P quotient shows massive shift to cranialisation of the tibiofemoral joint line which does not correspond to reality. The modified method also shows cranialisation of the tibiofemoral joint line, but in a realistic way. Both methods show a minimal interobserver variability. The modified JL/P quotient seems to be a good method for determining the shift in the tibiofemoral joint line after total knee arthroplasty. (orig.) [German] Ein bedeutender Faktor fuer ein gutes postoperatives Ergebnis nach einer Knieendoprothesenimplantation ist die Stellung der Patella in Relation zur tibiofemoralen Gelenklinie. Da die Stellung der Patella durch den operativen Eingriff primaer nicht beeinflusst wird, liegt besonderes Augenmerk auf den Veraenderungen der Gelenklinie des Tibiofemoralgelenks. Die Messmethode zur Bestimmung der Patellahoehe nach Figgie liefert dafuer nur absolute Werte, was eine Vergleichbarkeit von

  12. Comparison of different methods of assessing the tar content of gases from wood gasification; Vergleich verschiedener Methoden zur Bestimmung des Teergehalts in Gasen aus der Holzvergasung

    Energy Technology Data Exchange (ETDEWEB)

    Moersch, O; Spliethoff, H; Hein, K R.G. [Stuttgart Univ. (Germany). Inst. fuer Verfahrenstechnik und Dampfkesselwesen

    1998-09-01

    The authors present a method developed at the Institute of Chemical Engineering and Steam Boiler Technology (IVD) of Stuttgart University for quasi-continuous online measurement of tar concentrations in gases from biomass gasification. The method is compared with other methods in terms of time requirements, accuracy, and cost: Gravimetry, wet chemical analysis, solid phase amino-adsorption (SPA), and online process gas chromatography. The measurements were carried out on the fluidized-bed combustion system of the IVD. Wood was gasified at 800 degrees centigrade with a fuel/air ratio of 0.25. The measured tar concentrations differed widely, i.e. between 0.8 and 6.8 g per cubic metre. (orig.) [Deutsch] In dieser Arbeit wird ein am Institut fuer Verfahrenstechnik und Dampfkesselwesen (IVD) entwickeltes Verfahren zur quasikontinuierlichen Online-Messung des Teergehalts im Gas aus der Biomassevergasung vorgestellt und mit anderen Methoden aus der Literatur im Hinblick auf Zeitaufwand, Genauigkeit und Kosten verglichen. Untersucht wurden dabei eine gravimetrische Methode, die nasschemische Bestimmung, das Solid-Phase-Amino Adsorptionsverfahren (SPA), sowie die Online Analyse mittels Prozess-Gaschromatograph. Die Messungen wurden an der Wirbelschichtvergasungsanlage des IVD durchgefuehrt. Vergast wurde Holz bei 800 C und einer Luftzahl von 0.25. Der mit den verschiedenen Verfahren ermittelte Teergehalt unterscheidet sich zum Teil erheblich. Es ergaben sich Werte zwischen 0.8 und 6.8 g/m{sup 3}. (orig.)

  13. Using Compton scattering for random coincidence rejection

    International Nuclear Information System (INIS)

    Kolstein, M.; Chmeissani, M.

    2016-01-01

    The Voxel Imaging PET (VIP) project presents a new approach for the design of nuclear medicine imaging devices by using highly segmented pixel CdTe sensors. CdTe detectors can achieve an energy resolution of ≈ 1% FWHM at 511 keV and can be easily segmented into submillimeter sized voxels for optimal spatial resolution. These features help in rejecting a large part of the scattered events from the PET coincidence sample in order to obtain high quality images. Another contribution to the background are random events, i.e., hits caused by two independent gammas without a common origin. Given that 60% of 511 keV photons undergo Compton scattering in CdTe (i.e. 84% of all coincidence events have at least one Compton scattering gamma), we present a simulation study on the possibility to use the Compton scattering information of at least one of the coincident gammas within the detector to reject random coincidences. The idea uses the fact that if a gamma undergoes Compton scattering in the detector, it will cause two hits in the pixel detectors. The first hit corresponds to the Compton scattering process. The second hit shall correspond to the photoelectric absorption of the remaining energy of the gamma. With the energy deposition of the first hit, one can calculate the Compton scattering angle. By measuring the hit location of the coincident gamma, we can construct the geometric angle, under the assumption that both gammas come from the same origin. Using the difference between the Compton scattering angle and the geometric angle, random events can be rejected.

  14. Identification of peaks in multidimensional coincidence {gamma}-ray spectra

    Energy Technology Data Exchange (ETDEWEB)

    Morhac, Miroslav E-mail: fyzimiro@savba.sk; Kliman, Jan; Matousek, Vladislav; Veselsky, Martin; Turzo, Ivan

    2000-03-21

    In the paper a new algorithm to find peaks in two, three and multidimensional spectra, measured in large multidetector {gamma}-ray arrays, is derived. Given the dimension m, the algorithm is selective to m-fold coincidence peaks. It is insensitive to intersections of lower-fold coincidences, hereinafter called ridges.

  15. Identification of peaks in multidimensional coincidence γ-ray spectra

    International Nuclear Information System (INIS)

    Morhac, Miroslav; Kliman, Jan; Matousek, Vladislav; Veselsky, Martin; Turzo, Ivan

    2000-01-01

    In the paper a new algorithm to find peaks in two, three and multidimensional spectra, measured in large multidetector γ-ray arrays, is derived. Given the dimension m, the algorithm is selective to m-fold coincidence peaks. It is insensitive to intersections of lower-fold coincidences, hereinafter called ridges

  16. Video Histories, Memories, and Coincidences

    DEFF Research Database (Denmark)

    Kacunko, Slavko

    2012-01-01

    Looping images allows us to notice things that we have never noticed before. Looping a small but exquisite selection of the video tapes of Marcel Odenbach, Dieter Kiessling and Matthias Neuenhofer may allow the discovering of Histories, Coincidences, and Infinitesimal Aesthetics inscribed...

  17. Timing coincidence studies with fast photomultipliers

    International Nuclear Information System (INIS)

    Raoof, M.A.; Raoof, S.A.

    1981-01-01

    The time response of RCA C70045D photomultipliers was studied using a subnanosecond light flasher. The tubes, which have an output rise time of approximately 0.5 ns, were used in coincidence to study the variations in the fwhm of the time spectrum over a certain dynamic range of pulse amplitudes for both leading edge and constant fraction discrimination. A comparison has also been made for the measured time resolutions with some of the other fast photomultipliers. (orig.)

  18. The mirror symmetric centroid difference method for picosecond lifetime measurements via {gamma}-{gamma} coincidences using very fast LaBr{sub 3}(Ce) scintillator detectors

    Energy Technology Data Exchange (ETDEWEB)

    Regis, J.-M., E-mail: regis@ikp.uni-koeln.d [Institut fuer Kernphysik, Universitaet zu Koeln, Zuelpicher Str. 77, 50937 Koeln (Germany); Pascovici, G.; Jolie, J.; Rudigier, M. [Institut fuer Kernphysik, Universitaet zu Koeln, Zuelpicher Str. 77, 50937 Koeln (Germany)

    2010-10-01

    The ultra-fast timing technique was introduced in the 1980s and is capable of measuring picosecond lifetimes of nuclear excited states with about 3 ps accuracy. Very fast scintillator detectors are connected to an electronic timing circuit and detector vs. detector time spectra are analyzed by means of the centroid shift method. The very good 3% energy resolution of the nowadays available LaBr{sub 3}(Ce) scintillator detectors for {gamma}-rays has made possible an extension of the well-established fast timing technique. The energy dependent fast timing characteristics or the prompt curve, respectively, of the LaBr{sub 3}(Ce) scintillator detector has been measured using a standard {sup 152}Eu {gamma}-ray source. For any energy combination in the range of 200keVmeasurements is presented. The mirror symmetric centroid difference method takes advantage of the symmetry obtained when performing {gamma}-{gamma} lifetime measurements using a pair of almost identical very fast scintillator detectors. In particular cases, the use of the mirror symmetric centroid difference method also allows the direct determination of picosecond lifetimes, hence without the need of calibrating the prompt curve.

  19. Absolute activity measurement of the electron-capture-based radionuclides Ce-139, I-125, Ir-192 and Zn-65 by liquid scintillation coincidence counting

    CSIR Research Space (South Africa)

    Van Wyngaardt, WM

    2006-10-01

    Full Text Available experimentally by measur- ing NC=Ng. Eq. (1) can then be expressed as N4pNg NC ? N?1 C0f ??1 C0P??N?f ??1 C0f ?PPSC138 Ng NC . (4) When ?Ng=NC?!1 so will PS and the source activity is given by the corresponding extrapolated value of N4pNg=NC.AsNg=NC is varied, PS...

  20. Comparison of Water Vapor Measurements by Airborne Sun Photometer and Near-Coincident in Situ and Satellite Sensors during INTEX/ITCT 2004

    Science.gov (United States)

    Livingston, J.; Schmid, B.; Redemann, J.; Russell, P. B.; Ramirez, S. A.; Eilers, J.; Gore, W.; Howard, S.; Pommier, J.; Fetzer, E. J.; hide

    2007-01-01

    We have retrieved columnar water vapor (CWV) from measurements acquired by the 14-channel NASA Ames Airborne Tracking Sun photometer (AATS-14) during 19 Jetstream 31 (J31) flights over the Gulf of Maine in summer 2004 in support of the Intercontinental Chemical Transport Experiment (INTEX)/Intercontinental Transport and Chemical Transformation (ITCT) experiments. In this paper we compare AATS-14 water vapor retrievals during aircraft vertical profiles with measurements by an onboard Vaisala HMP243 humidity sensor and by ship radiosondes and with water vapor profiles retrieved from AIRS measurements during eight Aqua overpasses. We also compare AATS CWV and MODIS infrared CWV retrievals during five Aqua and five Terra overpasses. For 35 J31 vertical profiles, mean (bias) and RMS AATS-minus-Vaisala layer-integrated water vapor (LWV) differences are -7.1 percent and 8.8 percent, respectively. For 22 aircraft profiles within 1 hour and 130 km of radiosonde soundings, AATS-minus-sonde bias and RMS LWV differences are -5.4 percent and 10.7 percent, respectively, and corresponding J31 Vaisala-minus-sonde differences are 2.3 percent and 8.4 percent, respectively. AIRS LWV retrievals within 80 lan of J31 profiles yield lower bias and RMS differences compared to AATS or Vaisala retrievals than do AIRS retrievals within 150 km of the J31. In particular, for AIRS-minus-AATS LWV differences, the bias decreases from 8.8 percent to 5.8 percent, and the RMS difference decreases from 2 1.5 percent to 16.4 percent. Comparison of vertically resolved AIRS water vapor retrievals (LWVA) to AATS values in fixed pressure layers yields biases of -2 percent to +6 percent and RMS differences of -20 percent below 700 hPa. Variability and magnitude of these differences increase significantly above 700 hPa. MODIS IR retrievals of CWV in 205 grid cells (5 x 5 km at nadir) are biased wet by 10.4 percent compared to AATS over-ocean near-surface retrievals. The MODIS-Aqua subset (79 grid cells

  1. Statistical methods for the analysis of left-censored variables [Statistische Analysemethoden für linkszensierte Variablen und Beobachtungen mit Werten unterhalb einer Bestimmungs- oder Nachweisgrenze

    Directory of Open Access Journals (Sweden)

    Pesch, Beate

    2013-03-01

    Full Text Available [english] In some applications statisticians are confronted with values which are reported to be below a limit of detection or quantitation. These left-censored variables are a challenge in the statistical analysis. In a simulation study, we compare different methods to deal with this type of data in statistical applications. These include measures of location, dispersion, association, and statistical modeling. Our simulation study showed that the multiple imputation approach and the Tobit regression lead to unbiased estimates, whereas the naïve methods including simple substitution of non-detects lead to unreliable estimates. We illustrate the application of the multiple imputation approach and the Tobit regression with an example from occupational epidemiology. [german] In der statistischen Praxis treten immer wieder Variablen mit Werten unterhalb einer Bestimmungs- oder Nachweisgrenze auf. Diese sind linkszensiert und stellen daher eine Herausforderung für die statistische Analyse dar. Im Rahmen einer Simulationsstudie vergleichen wir Schätzmethoden zur Berechnung von Lage- und Streuungmaßen, Korrelationen und Regressionsparametern bei diesen Variablen. Unsere Ergebnisse zeigen, dass die multiple Imputationsmethode und die Tobit Regression zu unverzerrten Schätzungen führen. Naive Methoden, einschließlich der einfachen Substitution von zensierten Beobachtungen, ergeben hingegen unzuverlässige Schätzungen. Wir illustrieren die Anwendung der multiplen Imputationsmethode und der Tobit Regression anhand eines Beispiels aus der Epidemiologie der Arbeitswelt.

  2. Rheological online determination of the organic dry substance concentration of sewage sludge; Rheologische online Bestimmung des oTS-Gehalts von Klaerschlamm

    Energy Technology Data Exchange (ETDEWEB)

    Schmitz, P.; Boehm, A.; Fessler, J.; Liebelt, U. [BASF AG, Ludwigshafen am Rhein (Germany); Traegner, U. [Fachhochschule fuer Technik, Mannheim (Germany)

    1999-07-01

    In order to adjust the filter cake to a certain calorific value and to enhance the dehydratability of sludge, ash, carbon and flocculation agents are added to the latter prior to filtration. Dosage of the additives depends on the sludge's content of organic solids, determined in the form of the so-called organic dry substance concentration. In bench-scale and technical-scale experiments on the rheological properties of sewage sludge, a correlation between organic dry substance concentration and rheological properties, especially the liquid limit of sewage sludge, was established. This knowledge was used to develop a measuring technique for online determination of organic dry substance concentration by means of rheology. (orig.) [German] Zur Einstellung eines bestimmten Heizwertes des Filterkuchens und zur Verbesserung der Entwaesserbarkeit werden dem Schlamm vor der Filtration Asche, Kohle und Flockungsmittel zugegeben. Die Dosierung der Zuschlagsstoffe erfolgt in Abhaengigkeit vom Gehalt des Schlamms an organischem Feststoff, bestimmt in Form der sog. oTS-Konzentration. In Labor- und Betriebsversuchen zum rheologischen Verhalten von Klaerschlamm konnte eine Korrelation zwischen der oTS-Konzentration und den Fliesseigenschaften, insbesondere der Fliessgrenze von Klaerschlamm ermittelt werden. Diese Erkenntnis wurde in ein Messverfahren zur online-Bestimmung der oTS-Konzentration mittels Rheologie umgesetzt. (orig.)

  3. Comparison of the target-thickness dependence of the convoy electron yield and the Rydberg electron yield measured in coincidence with exit charge states in fast ion-solid collisions

    International Nuclear Information System (INIS)

    Gaither, C.C. III; Breinig, M.; Freyou, J.; Underwood, T.A.

    1988-01-01

    We have simultaneously measured the yield of convoy electrons and the yield of electrons in high Rydberg states of the projectile (n /approx gt/ 70), produced by 2MeV/u C projectiles passing through C foils, whose thicknesses range from 4--10 ug/cm 2 , for incident charge states q/sub i/ = 4--6 and exit charge states q/sub e/ = 4--6. We have found that these yields exhibit similar trends as a function of foil thickness, but that, nevertheless, the ratio of the number of convoy electrons detected in coincidence with ions of exit charge state q/sub e/ to the number of electrons detected in high Rydberg states of ions with the same exit charge state is a function of foil thickness. This may be due to a broadening of the convoy electron energy spectrum with increasing foil thickness. 6 refs., 3 figs

  4. Formulation of the fundamental basis for the evaluation of the comparability of different measuring method for the determination of ground air radon concentration. Vol. 1. Final report; Erarbeitung fachlicher Grundlagen zur Beurteilung der Vergleichbarkeit unterschiedlicher Messmethoden zur Bestimmung der Radonbodenluftkonzentration. Bd. 1. Abschlussbericht

    Energy Technology Data Exchange (ETDEWEB)

    Kemski, J.; Klingel, R.; Siehl, A.; Neznal, M.; Matolin, M.

    2012-03-15

    The final report on report on ground air radon measurements includes the following chapters: Scope of the research program; Concept of the research project; Development of a passive method for ground air measurement; Sampling and measuring methods; Measured areas; Field measurements; results of geophysical investigations: Castle Lede, Messdorfer Field; Lounovice; Procedural method; Results of ground air radon concentration measurements, meteorological and geophysical parameters; Evaluation, discussion and conclusions.

  5. Standardisation of 64Cu using a software coincidence counting system

    International Nuclear Information System (INIS)

    Havelka, Miroslav; Sochorová, Jana

    2014-01-01

    The activity of the radionuclide 64 Cu was determined by the efficiency extrapolation method applied to 4π(PC)−γ coincidence counting. The standardisation was performed by software coincidence counting—a digital method for primary activity measurement that simplifies the setting of optimal coincidence parameters. The γ-ray-energy window, characterised by identical gamma detection efficiency related to the sum of EC and to the sum of beta decay branches, was found. This setting ensured a linear and zero slope extrapolation curve. - Highlights: • Standardisation realised by extrapolation method applied to 4π(PC)−γ coincidence. • Digital method for optimal setting of coincidence parameters was used. • Result with total standard uncertainty of 0.74% was obtained

  6. Multiple channel programmable coincidence counter

    Science.gov (United States)

    Arnone, Gaetano J.

    1990-01-01

    A programmable digital coincidence counter having multiple channels and featuring minimal dead time. Neutron detectors supply electrical pulses to a synchronizing circuit which in turn inputs derandomized pulses to an adding circuit. A random access memory circuit connected as a programmable length shift register receives and shifts the sum of the pulses, and outputs to a serializer. A counter is input by the adding circuit and downcounted by the seralizer, one pulse at a time. The decoded contents of the counter after each decrement is output to scalers.

  7. Software correction of scatter coincidence in positron CT

    International Nuclear Information System (INIS)

    Endo, M.; Iinuma, T.A.

    1984-01-01

    This paper describes a software correction of scatter coincidence in positron CT which is based on an estimation of scatter projections from true projections by an integral transform. Kernels for the integral transform are projected distributions of scatter coincidences for a line source at different positions in a water phantom and are calculated by Klein-Nishina's formula. True projections of any composite object can be determined from measured projections by iterative applications of the integral transform. The correction method was tested in computer simulations and phantom experiments with Positologica. The results showed that effects of scatter coincidence are not negligible in the quantitation of images, but the correction reduces them significantly. (orig.)

  8. Numerical coincidences and 'tuning' in cosmology

    OpenAIRE

    Rees, Martin J.

    2004-01-01

    Fred Hoyle famously drew attention to the significance of apparent coincidences in the energy levels of the carbon and oxygen nucleus. This paper addresses the possible implications of other coincidences in cosmology.

  9. Formulation of the fundamental basis for the evaluation of the comparability of different measuring method for the determination of ground air radon concentration. Vol. 2. Report on ground air radon measurements - influence factors, measuring methods, evaluation; Erarbeitung fachlicher Grundlagen zur Beurteilung der Vergleichbarkeit unterschiedlicher Messmethoden zur Bestimmung der Radonbodenluftkonzentration. Bd. 2. Sachstandsbericht ''Radonmessungen in der Bodenluft - Einflussfaktoren, Messverfahren, Bewertung''

    Energy Technology Data Exchange (ETDEWEB)

    Kemski, J.; Klingel, R.; Siehl, A.; Neznal, M.; Matolin, M.

    2012-03-15

    The report on ground air radon measurements covers the following issues: Introduction; Radon in the geogenic underground: emanation, migration, exhalation; Influencing factors: geochemical parameters, structural situation, geomorphology, exogenic effects; Ground air measurements: site exploration, tectonics, earth quake prognosis, radon in ground air and buildings; Radon measurement: sampling and measuring methods, error consideration, comparative measurements, practical examples; measuring regulations and recommendations; Variability of the radon concentration: temporal variation, sampling depth, spatial variations; Evaluation and conclusions.

  10. Monte Carlo calculations of the neutron coincidence gate utilisation factor for passive neutron coincidence counting

    International Nuclear Information System (INIS)

    Bourva, L.C.A.; Croft, S.

    1999-01-01

    basis, previously published analytical results for the double exponential case are thought to be in error. As derived analytically, the numerical calculations have been found to be both independent of the detector's efficiency and of the spontaneous fission neutron multiplicity distribution used in the Monte Carlo calculations. Extension of the MCF calculations to multiplicity counting, and in particular to triple coincidence counting, confirmed that, for a single exponential die-away profile, the triple gate utilisation factor is equal to the square of the real gate utilisation factor. For other profiles this relation no longer holds. An analytical expression is given for the case of a double exponential profile. Comparison of the MCF results with earlier calculated estimates of the gate utilisation factor for the on-site laboratory neutron coincidence chamber showed a significant difference. Use of the MCF results led to much better agreement between the observed and calculated specific reals coincidence rate of the on-site laboratory counter for the assay of plutonium samples. Moreover, the present work constitutes a further step towards the improvement of the accuracy of absolute Monte Carlo calculations for active or passive neutron measurements of nuclear materials. (author)

  11. Computed neutron coincidence counting applied to passive waste assay

    Energy Technology Data Exchange (ETDEWEB)

    Bruggeman, M.; Baeten, P.; De Boeck, W.; Carchon, R. [Nuclear Research Centre, Mol (Belgium)

    1997-11-01

    Neutron coincidence counting applied for the passive assay of fissile material is generally realised with dedicated electronic circuits. This paper presents a software based neutron coincidence counting method with data acquisition via a commercial PC-based Time Interval Analyser (TIA). The TIA is used to measure and record all time intervals between successive pulses in the pulse train up to count-rates of 2 Mpulses/s. Software modules are then used to compute the coincidence count-rates and multiplicity related data. This computed neutron coincidence counting (CNCC) offers full access to all the time information contained in the pulse train. This paper will mainly concentrate on the application and advantages of CNCC for the non-destructive assay of waste. An advanced multiplicity selective Rossi-alpha method is presented and its implementation via CNCC demonstrated. 13 refs., 4 figs., 2 tabs.

  12. Computed neutron coincidence counting applied to passive waste assay

    International Nuclear Information System (INIS)

    Bruggeman, M.; Baeten, P.; De Boeck, W.; Carchon, R.

    1997-01-01

    Neutron coincidence counting applied for the passive assay of fissile material is generally realised with dedicated electronic circuits. This paper presents a software based neutron coincidence counting method with data acquisition via a commercial PC-based Time Interval Analyser (TIA). The TIA is used to measure and record all time intervals between successive pulses in the pulse train up to count-rates of 2 Mpulses/s. Software modules are then used to compute the coincidence count-rates and multiplicity related data. This computed neutron coincidence counting (CNCC) offers full access to all the time information contained in the pulse train. This paper will mainly concentrate on the application and advantages of CNCC for the non-destructive assay of waste. An advanced multiplicity selective Rossi-alpha method is presented and its implementation via CNCC demonstrated. 13 refs., 4 figs., 2 tabs

  13. Neue biosensorische Prinzipien für die Hämoglobin-A1c Bestimmung

    Science.gov (United States)

    Stöllner, Daniela

    2002-06-01

    Hämoglobin-A1c (HbA1c) ist ein Hämoglobin (Hb)-Subtypus, der durch nicht-enzymatische Glykierung des N-terminalen Valinrestes der Hämoglobin-beta-Kette entsteht. Das gemessene Verhältnis von HbA1c zum Gesamt-Hämoglobin (5-20 % bei Diabetikern) repräsentiert den Mittelwert der Blutglucosekonzentration über einen zweimonatigen Zeitraum und stellt zur Beurteilung der diabetischen Stoffwechsellage eine Ergänzung zur Akutkontrolle der Glukosekonzentration dar. Ziel der vorliegenden Arbeit war es, einen amperometrischen Biosensor für die Bestimmung des medizinisch relevanten Parameters HbA1c zu entwickeln. Durch Selektion geeigneter Bioerkennungselemente und deren Immobilisierung unter Erhalt der Bindungsfunktion für die Zielmoleküle Hämoglobin bzw. HbA1c wurden spezifische, hochaffine und regenerationsstabile Sensoroberflächen geschaffen. Für die Entwicklung des HbA1c-Biosensors wurden zwei Konzepte - Enzymsensor und Immunosensor - miteinander verglichen. Die enzymatische Umsetzung von HbA1c erfolgte mit der Fructosylamin Oxidase (FAO) aus Pichia pastoris N 1-1 unter Freisetzung von H2O2, welches sowohl optisch über eine Indikatorreaktion als auch elektrochemisch nach Einschluss der FAO in PVA-SbQ und Fixierung des Immobilisats vor einer H2O2-Elektrode nachgewiesen wurde. Die Kalibration des Enzymsensors mit der HbA1c-Modellsubstanz Fructosyl-Valin ergab Nachweisgrenzen, die ausserhalb des physiologisch relevanten HbA1c-Konzentrationsbereich lagen. Aus der Umsetzung von glykierten Peptiden mit einer nicht HbA1c analogen Aminosäurensequenz, z.B. Fructosyl-Valin-Glycin wurde zudem eine geringe HbA1c-Spezifität abgeleitet. Für den Immunosensor wurden zwei heterogene Immunoassay-Formate unter Verwendung von hochaffinen und spezifischen Antikörpern in Kombination mit Glucose Oxidase (GOD) als Markerenzym zum Nachweis von HbA1c untersucht. Beim indirekt-kompetitiven Immunoassay wurde anstelle des kompletten HbA1c-Moleküls das glykierte Pentapeptid

  14. Time and Energy Characterization of a Neutron Time of Flight Detector Using a Novel Coincidence Method for Constraining Neutron Yield, Ion Temperature and Liner Density Measurements from MagLIF Experiments

    Science.gov (United States)

    Styron, Jedediah D.

    The focus of this work is the characterization of a typical neutron time-of-flight (NTOF) detector that is fielded on inertial confinement fusion (ICF) experiments conducted at the Z-experimental facility with emphasis on the Magnetized Liner Fusion (MagLIF) concept. An NTOF detector consisting of EJ-228 scintillator and two independent photomultiplier tubes (PMTs), a Hamamatsu-mod 5 and Photek-PMT240, has been characterized in terms of the absolute time and energy response. The characterization was done by measuring single, neutron-induced events in the scintillator by measuring the alpha particle and neutron produced from the D-T reaction in kinematic coincidence. The results of these experiments provided the time dependent instrument response function and the detector sensitivity as a function of applied voltage covering the entire dynamic range of the detector. Historically, impulse response functions have been measured using various photon sources as surrogates for a neutron source. Thus, this measurement using a single hit neutron source results in the most accurate measured response function, which will improve the accuracy of impulse response corrections to the NTOF signals. While this detector has not yet been fielded on any MagLIF experiments, the development of a predictive capability was desired for transferring the measured detector response from the calibration geometry to the more complex Z geometry. As a proof-of-principle, a detailed model of the Z-machine was developed in MCNP6 to correct for geometry issues when transferring the calibration results from a light lab setting to the Z-environment. Representative values for the instrument response function and the sensitivity for the current detectors fielded on MagLIF experiments were convolved with the modeled results. These results were compared with data collected on three previous MagLIF experiments. The comparison shows the model results can be used to constrain three parameters that are

  15. Methods of measuring floor resistance; Messverfahren zur Bestimmung des Ableitwiderstandes von Fussboeden

    Energy Technology Data Exchange (ETDEWEB)

    Seemann, A. [BGFW Berufsgenossenschaft der Gas-, Fernwaerme- und Wasserwirtschaft, Duesseldorf (Germany); Tutschek, G.; Warszewski, P. [Ruhrgas AG, Essen (Germany). Abt. Anlagensicherheit

    2001-04-01

    In gas fitting plants where explosive gas/air mixtures can occur the flooring materials must be conductive. Persons who are insulated from earth can easily acquire and retain an electrostatic charge. If an electrostatically charged person touches a conducting object (e.g. pipe, gas fitting plant) a spark occur at the point of contact. Such sparks can cause ignition of an explosive gas/air mixture. To avoid the retention of static electricity the recommended level of the earth of a floor must be lower than 10{sup 8} {omega} and the persons have to wear dissipative footwear. In several standards methods for checking floor resistance are described. A useful test method is given in DIN EN 1081. (orig.) [German] Explosionsfaehige Erdgas-/Luftgemische koennen durch elektrostatische Entladungsfunken gezuendet werden. Um eine elektrostatische Aufladung von Personen zu vermeiden, darf der Ableitwiderstand des Fussbodens den Wert von 10{sup 8} {omega} nicht ueberschreiten, und es muss ableitfaehiges Schuhwerk getragen werden. In verschiedenen Normen sind Messerfahren fuer die Ueberpruefung des Ableitwiderstandes von verlegten Fussboeden angegeben. Eine fuer die Praxis brauchbare Messmethode wird in DIN EN 1081 angegeben. (orig.)

  16. Analysis method for beta-gamma coincidence spectra from radio-xenon isotopes

    International Nuclear Information System (INIS)

    Yang Wenjing; Yin Jingpeng; Huang Xiongliang; Cheng Zhiwei; Shen Maoquan; Zhang Yang

    2012-01-01

    Radio-xenon isotopes monitoring is one important method for the verification of CTBT, what includes the measurement methods of HPGe γ spectrometer and β-γ coincidence. The article describes the analytic flowchart and method of three-dimensional beta-gamma coincidence spectra from β-γ systems, and analyses in detail the principles and methods of the regions of interest of coincidence spectra and subtracting the interference, finally gives the formula of radioactivity of Xenon isotopes and minimum detectable concentrations. Studying on the principles of three-dimensional beta-gamma coincidence spectra, which can supply the foundation for designing the software of β-γ coincidence systems. (authors)

  17. Design and development of VHDL based IP core for coincidence analyzer for FPGA based TDCR system

    International Nuclear Information System (INIS)

    Agarwal, Shivam; Gupta, Ashutosh; Chaudhury, Probal; Sharma, M.K.; Kulkarni, M.S.

    2018-01-01

    The coincidence counting technique is used in activity measurement methods to determine the activity of radionuclide e.g. 4πβ-γ method and Triple to Double Coincidence Ratio (TDCR) method etc. The 4πβ-γ method requires two inputs Coincidence Analyzer (CA) whereas; TDCR method requires three inputs CA. A VHDL (Very High Speed Integrated Circuit Hardware Description Language) based IP (Intellectual Property) core for coincidence analyzer has been designed and implemented in FPGA (Field Programmable Gate Array) for TDCR system. The developed IP not only facilitates the coincidence counting of three channels simultaneously but also provides an extendable dead time feature

  18. More accurate thermal neutron coincidence counting technique

    International Nuclear Information System (INIS)

    Baron, N.

    1978-01-01

    Using passive thermal neutron coincidence counting techniques, the accuracy of nondestructive assays of fertile material can be improved significantly using a two-ring detector. It was shown how the use of a function of the coincidence count rate ring-ratio can provide a detector response rate that is independent of variations in neutron detection efficiency caused by varying sample moderation. Furthermore, the correction for multiplication caused by SF- and (α,n)-neutrons is shown to be separable into the product of a function of the effective mass of 240 Pu (plutonium correction) and a function of the (α,n) reaction probability (matrix correction). The matrix correction is described by a function of the singles count rate ring-ratio. This correction factor is empirically observed to be identical for any combination of PuO 2 powder and matrix materials SiO 2 and MgO because of the similar relation of the (α,n)-Q value and (α,n)-reaction cross section among these matrix nuclei. However the matrix correction expression is expected to be different for matrix materials such as Na, Al, and/or Li. Nevertheless, it should be recognized that for comparison measurements among samples of similar matrix content, it is expected that some function of the singles count rate ring-ratio can be defined to account for variations in the matrix correction due to differences in the intimacy of mixture among the samples. Furthermore the magnitude of this singles count rate ring-ratio serves to identify the contaminant generating the (α,n)-neutrons. Such information is useful in process control

  19. Coincidence and covariance data acquisition in photoelectron and -ion spectroscopy. II. Analysis and applications

    Science.gov (United States)

    Mikosch, Jochen; Patchkovskii, Serguei

    2013-10-01

    We use an analytical theory of noisy Poisson processes, developed in the preceding companion publication, to compare coincidence and covariance measurement approaches in photoelectron and -ion spectroscopy. For non-unit detection efficiencies, coincidence data acquisition (DAQ) suffers from false coincidences. The rate of false coincidences grows quadratically with the rate of elementary ionization events. To minimize false coincidences for rare event outcomes, very low event rates may hence be required. Coincidence measurements exhibit high tolerance to noise introduced by unstable experimental conditions. Covariance DAQ on the other hand is free of systematic errors as long as stable experimental conditions are maintained. In the presence of noise, all channels in a covariance measurement become correlated. Under favourable conditions, covariance DAQ may allow orders of magnitude reduction in measurement times. Finally, we use experimental data for strong-field ionization of 1,3-butadiene to illustrate how fluctuations in experimental conditions can contaminate a covariance measurement, and how such contamination can be detected.

  20. Does an individual estimation of halflife improve the results of radioiodine therapy of Graves' disease?; Verbessert die individuelle Bestimmung der effektiven Halbwertszeit die Ergebnisse der Radioiodtherapie des Morbus Basedow?

    Energy Technology Data Exchange (ETDEWEB)

    Schneider, P.; Koerber, C.; Koerber-Hafner, N.; Haenscheid, H.; Reiners, Chr. [Klinik und Poliklinik fuer Nuklearmedizin der Univ. Wuerzburg (Germany)

    2002-12-01

    Aim: The impact of our dosimetry concept on radioiodine therapy success in Graves' disease (GD) was analysed. Three questions arised: Did individual estimation of pretherapeutic halflife improve therapeutic success? Did individual dosimetry result in accurate dose calculation? Did antithyroid medication have a measurable influence on therapeutic success under the prevailing conditions? Methods: 126 consecutive patients were treated with 200 Gy I-131 in our therapy ward for GD and followed-up six to nine months after therapy. Success quote was assessed using a standardized protocol and treatment was classified as successful when the patients was eu- or hypothyroid, or unsuccessful when he or she presented with a suppressed TSH-level or in hyperthyroid condition after antithyroid medication withdrawal. Antithyroid medication, activity I-131, dose, concentration of fT{sub 3} and fT{sub 4}, specific delivered dose and halflife were put into a multiple regression model to assess their influence on therapeutic success. In order to assess possible factors disturbing the therapeutic outcome, relevant parameters were analyzed using Logit transformation. Results: Out of 126 patients 84 were classified as successfully treated and 42 (33,3%) as failures. A significant influence on the outcome only was found for thyroid mass. However, therapeutic success appeared to be more distinctly determined by the specific delivered dose using an estimated halflife of 5.5 days (Odds: 10.0, p <0.001). Accurate intratherapeutic dosimetry did not play a significant role to enhance therapeutic success. Neither did antihyroid medication during radioiodine therapy exert any significant impact. Conclusions: Measurement of individual intratherapeutic halflife as opposed to an estimate using a standard halflife did not provide improved results concerning the target dose. Retrospectively, the therapeutic outcome on the basis of a measured halflife as compared to a standard halflife did not

  1. Importance of interpolation and coincidence errors in data fusion

    Science.gov (United States)

    Ceccherini, Simone; Carli, Bruno; Tirelli, Cecilia; Zoppetti, Nicola; Del Bianco, Samuele; Cortesi, Ugo; Kujanpää, Jukka; Dragani, Rossana

    2018-02-01

    The complete data fusion (CDF) method is applied to ozone profiles obtained from simulated measurements in the ultraviolet and in the thermal infrared in the framework of the Sentinel 4 mission of the Copernicus programme. We observe that the quality of the fused products is degraded when the fusing profiles are either retrieved on different vertical grids or referred to different true profiles. To address this shortcoming, a generalization of the complete data fusion method, which takes into account interpolation and coincidence errors, is presented. This upgrade overcomes the encountered problems and provides products of good quality when the fusing profiles are both retrieved on different vertical grids and referred to different true profiles. The impact of the interpolation and coincidence errors on number of degrees of freedom and errors of the fused profile is also analysed. The approach developed here to account for the interpolation and coincidence errors can also be followed to include other error components, such as forward model errors.

  2. IMPECC, new 4 π β γ coincidence system

    International Nuclear Information System (INIS)

    Bouchard, J.; Chauvenet, B.; Vatin, R.

    1988-05-01

    The new 4 π β γ coincidence system IMPECC which uses an extensible dead time circuit common to both channels is described. Correction formulae which take into account the particularities of the electronics are also presented. The use of two ADC's and the symmetry in the two channels gives us a very powerful instrument when measuring complex decay scheme radionuclides [fr

  3. Positron two-photon annihilation coincidence technique: difference mode

    Energy Technology Data Exchange (ETDEWEB)

    Karol, P J; Klobuchar, R L [Carnegie-Mellon Univ., Pittsburgh, Pa. (USA). Dept. of Chemistry

    1978-05-01

    A difference (or comparative) mode in the measurement of two-photon coincidences from positron or positronium annihilation has been developed. The method can be used to advantage, particularly in gases, in determining annihilation parameters such as quenching cross sections for low concentration strongly quenching chemical species in a reference medium which is relatively non-quenching.

  4. Statistical data filtration in neutron coincidence counting

    International Nuclear Information System (INIS)

    Beddingfield, D.H.; Menlove, H.O.

    1992-11-01

    We assessed the effectiveness of statistical data filtration to minimize the contribution of matrix materials in 200-ell drums to the nondestructive assay of plutonium. Those matrices were examined: polyethylene, concrete, aluminum, iron, cadmium, and lead. Statistical filtration of neutron coincidence data improved the low-end sensitivity of coincidence counters. Spurious data arising from electrical noise, matrix spallation, and geometric effects were smoothed in a predictable fashion by the statistical filter. The filter effectively lowers the minimum detectable mass limit that can be achieved for plutonium assay using passive neutron coincidence counting

  5. Coincidence gamma-ray spectrometry

    DEFF Research Database (Denmark)

    Markovic, Nikola; Roos, Per; Nielsen, Sven Poul

    2017-01-01

    Gamma-ray spectrometry with high-purity germanium (HPGe) detectors is often the technique of choice in an environmental radioactivity laboratory. When measuring environmental samples associated activities are usually low so an important parameter that describes the performance of the spectrometer...... for a nuclide of interest is the minimum detectable activity (MDA). There are many ways for lowering the MDAs in gamma spectrometry. Recently, developments of fast and compact digital acquisition systems have led to growing number of multiple HPGe detector spectrometers. In these applications all detected...

  6. Coincident effect characteristic in a thermoacoustic regenerator

    International Nuclear Information System (INIS)

    Liu Yicai; Xin Tianlong; Huang Qian; Shi Xiangnan; Chen Siming; Chen Lixin

    2011-01-01

    Many previous studies on characteristics of thermoacoustic regenerator are based on fluid micro-groups and their compression-expansion cycle. In this paper, coincident frequency is introduced to evaluate its acoustic characteristics by combining structural acoustic with structural vibration theories. The relationship among structure wave radiation and regenerator position, slab thickness, and properties of material are analyzed by numerical calculation. The results show that in the low-frequency thermoacoustic system, the coincident effect generated by higher frequency wave weakens the fundamental sound wave. While in the high-frequency thermoacoustic system, where the oscillating fundamental frequency is higher than the coincident frequency, the sound field strength is enhanced by stronger structure wave radiation because of the coincident effect.

  7. A versatile fast coincidence system with memory

    International Nuclear Information System (INIS)

    Pouthas, J.

    1976-01-01

    A versatile fast coincidence system has been studied for experiments using several detectors. In this system, all the coincidence events are produced with an associated code, and thus, different kinds of events can be processed with the same experimental set-up. Also, the classification of the logical pulses gives the possibility of using a large number of ways (30 in this system). The setting of the system is very simple: there are only two time windows to adjust. (Auth.)

  8. Sensitive detection of hydrogen in a-Si:H by coincidence measurement of elastically scattered 100 MeV /sup 3/He/sup 2 +/ ions and recoil protons

    Energy Technology Data Exchange (ETDEWEB)

    Fukada, Noboru; Imura, Takeshi; Hiraki, Akio [Osaka Univ., Suita (Japan). Faculty of Engineering; Itahashi, Takahisa; Fukuda, Tomokazu; Tanaka, Masayoshi

    1982-09-01

    We have drastically improved the sensitivity of the nuclear elastic scattering (NES) method for determining hydrogen concentrations in hydrogenated amorphous silicon (a-Si:H) films. A beam of 100 MeV /sup 3/He/sup 2 +/ ions was used in the experiment. By taking the coincidence of detection of the scattered /sup 3/He ion with that of the recoil proton, we could achieve a sensitivity of 0.1 atomic percent with a precision of about 1 percent for 1 ..mu..m films.

  9. Simulation of triple coincidences in PET

    International Nuclear Information System (INIS)

    Cal-González, J; Herranz, E; Vicente, E; Udias, J M; Lage, E; Dave, S R; Parot, V; Herraiz, J L; Moore, S C; Park, M-A

    2015-01-01

    Although current PET scanners are designed and optimized to detect double coincidence events, there is a significant amount of triple coincidences in any PET acquisition. Triple coincidences may arise from causes such as: inter-detector scatter (IDS), random triple interactions (R T ), or the detection of prompt gamma rays in coincidence with annihilation photons when non-pure positron-emitting radionuclides are used (β + γ events). Depending on the data acquisition settings of the PET scanner, these triple events are discarded or processed as a set of double coincidences if the energy of the three detected events is within the scanner’s energy window. This latter option introduces noise in the data, as at most, only one of the possible lines-of-response defined by triple interactions corresponds to the line along which the decay occurred. Several novel works have pointed out the possibility of using triple events to increase the sensitivity of PET scanners or to expand PET imaging capabilities by allowing differentiation between radiotracers labeled with non-pure and pure positron-emitting radionuclides. In this work, we extended the Monte Carlo simulator PeneloPET to assess the proportion of triple coincidences in PET acquisitions and to evaluate their possible applications. We validated the results of the simulator against experimental data acquired with a modified version of a commercial preclinical PET/CT scanner, which was enabled to acquire and process triple-coincidence events. We used as figures of merit the energy spectra for double and triple coincidences and the triples-to-doubles ratio for different energy windows and radionuclides. After validation, the simulator was used to predict the relative quantity of triple-coincidence events in two clinical scanners assuming different acquisition settings. Good agreement between simulations and preclinical experiments was found, with differences below 10% for most of the observables considered. For

  10. Particle-gamma coincidence measurements in /sup 12/C+/sup 12/C and /sup 12/C+Pb collisions at 2. 1 GeV/nucleon incident energy

    Energy Technology Data Exchange (ETDEWEB)

    Roche, G.; Koontz, R.; Mulera, T.; Pugh, H.G.; Schroeder, L.S. (Lawrence Berkeley Lab., CA (USA)); Hallman, T.; Madansky, L. (Johns Hopkins Univ., Baltimore, MD (USA)); Carroll, J. (California Univ., Los Angeles (USA)); Chang, C.C. (Maryland Univ., College Park (USA)); Kirk, P.N.

    1985-06-24

    A particle-gamma coincidence experiment has been performed with a 2.1 GeV per nucleon /sup 12/C beam from the Bevalac. Data were taken with C and Pb targets. The ..gamma..-ray spectra are almost independent of the energy or the kind of charged particles detected in coincidence, mainly protons and deuterons. These ..gamma..-ray spectra are interpreted as resulting from ..pi../sup 0/ decay, and are consistent with known ..pi../sup 0/ production rates. A search for a possible decay of singly-charged anomalons into a gamma and a deuteron (or unbound proton-neutron system) has been done by studying the ..gamma..p and ..gamma..d invariant mass distributions. The upper limits for such a process are found to be 2 to 20% of the deuteron production rate, for anomalon masses for 200 to 400 MeV above the deuteron mass, with an anomalon mean lifetime of up to 10/sup -9/ s, depending on which kind of decay process is considered.

  11. Description and performance characteristics for the neutron Coincidence Collar for the verification of reactor fuel assemblies

    International Nuclear Information System (INIS)

    Menlove, H.O.

    1981-08-01

    An active neutron interrogation method has been developed for the measurement of 235 U content in fresh fuel assemblies. The neutron Coincidence Collar uses neutron interrogation with an AmLi neutron source and coincidence counting the induced fission reaction neutrons from the 235 U. This manual describes the system components, operation, and performance characteristics. Applications of the Coincidence Collar to PWR and BWR types of reactor fuel assemblies are described

  12. Elaboration of Co-60 sources on gilding vyns, with beta efficiencies 80 % or better and its activity measure by the coincidences method; Elaboracion de fuentes de Co-60 sobre vyns dorado, con eficiencias beta del 80 % o mejor y su medida de actividad por el metodo de coincidencias

    Energy Technology Data Exchange (ETDEWEB)

    Cortes P, A.; Tejera R, A.; Becerril V, A.; Ortiz C, A

    1991-12-15

    The measuring technique of radioactive activity by the coincidences method 4 {pi} {beta}{sup -} {gamma} it requires of the elaboration of radioactive sources on thin supports in order to flows the biggest percentage of beta particles, those of the order of the 80 % or but. In this work a procedure for the elaboration of this type of sources, with gilding Vyns is reported. (Author)

  13. Development of an Apparatus for High-Resolution Auger Photoelectron Coincidence Spectroscopy (APECS) and Electron Ion Coincidence (EICO) Spectroscopy

    Science.gov (United States)

    Kakiuchi, Takuhiro; Hashimoto, Shogo; Fujita, Narihiko; Mase, Kazuhiko; Tanaka, Masatoshi; Okusawa, Makoto

    We have developed an electron electron ion coincidence (EEICO) apparatus for high-resolution Auger photoelectron coincidence spectroscopy (APECS) and electron ion coincidence (EICO) spectroscopy. It consists of a coaxially symmetric mirror electron energy analyzer (ASMA), a miniature double-pass cylindrical mirror electron energy analyzer (DP-CMA), a miniature time-of-flight ion mass spectrometer (TOF-MS), a magnetic shield, an xyz stage, a tilt-adjustment mechanism, and a conflat flange with an outer diameter of 203 mm. A sample surface was irradiated by synchrotron radiation, and emitted electrons were energy-analyzed and detected by the ASMA and the DP-CMA, while desorbed ions were mass-analyzed and detected by the TOF-MS. The performance of the new EEICO analyzer was evaluated by measuring Si 2p photoelectron spectra of clean Si(001)-2×1 and Si(111)-7×7, and by measuring Si-L23VV-Si-2p Auger photoelectron coincidence spectra (Si-L23VV-Si-2p APECS) of clean Si(001)-2×1.

  14. Development of an online emission measuring system for quasi-continuous measurement of organic halgen compounds in off-gases of thermal processes. The example of polychlorinated dibeno-p-dioxins and dibenzofurans in pure gas of incinerators for domestic waste; Entwicklung einer on-line Emissionsmesstechnik zur quasi-kontinuierlichen Bestimmung von Organohalogen-Verbindungen in Abgasen thermischer Prozesse. Ausgefuehrt am Beispiel polychlorierter Dibenzo-p-dioxine und Dibenzofurane im Reingas von Hausmuellverbrennungsanlagen

    Energy Technology Data Exchange (ETDEWEB)

    Mohr, K.

    2000-07-01

    Industrial processes are connected with the emission of xenobiotic substances that represent a burden on the environment. Standardised methods currently available for the quantitative determination of these substances are time consuming, require a lot of work and are therefore expensive. Consequently they are not suited to perform extensive screening or monitoring programs. The aim of this work was therefore to develop a reliable quasi-continuous time and cost effective measuring method that can be used as a screening tool for the determination of such substances. The method has been developed according to stack emissions of polychlorinated dibenzo-p-dioxins (PCDD) and dibenzofurans (PCDF) in municipal solid waste incinerators (MSWIs). (orig.)

  15. Performance of an active well coincidence counter for HEU samples

    International Nuclear Information System (INIS)

    Ferrari, Francesca; Peerani, Paolo

    2010-01-01

    Neutron coincidence counting is the reference NDA technique used in nuclear safeguards to measure the mass of nuclear material in samples. For high-enriched uranium (HEU) samples active neutron interrogation is generally performed and the most common device used by nuclear inspectors is the Active Well Coincidence Counter (AWCC). Within her master thesis at the Polytechnic of Milan, the first author performed an intensive study on the characteristics and performances of the AWCC in order to assess the 235 U mass in HEU oxide samples at the PERLA laboratory of JRC. The work has been summarised in this paper that starts with the optimisation of the use of AWCC for nuclear safeguards, describing the calibration procedure, reporting results of a series of verification measurements, summarising the performances that can be obtained with this instruments during inspections at fuel production plants and concluding with the discussion of uncertainties related to these measurements.

  16. Using CHIMERA detector at LNS for gamma-particle coincidences

    Directory of Open Access Journals (Sweden)

    Cardella G.

    2016-01-01

    Full Text Available We have recently evaluated the quality of γ-ray angular distributions that can be extracted in particle-gamma coincidence measurements using the CHIMERA detector at LNS. γ-rays have been detected using the CsI(Tl detectors of the spherical part of the CHIMERA array. Very clean γ-rays angular distributions were extracted in reactions induced by different stable beams impinging on 12C thin targets. The results evidenced an effect of projectile spin flip on the γ-rays angular distributions. γ-particle coincidence measurements were also performed in reactions induced by neutron rich exotic beams produced through in-flight fragmentation at LNS. In recent experiments also the Farcos array was used to improve energy and angular resolution measurements of the detected charged particles. Results obtained with both stable and radioactive beams are reported.

  17. Quintessence, Cosmic Coincidence, and the Cosmological Constant

    International Nuclear Information System (INIS)

    Zlatev, I.; Wang, L.; Steinhardt, P.J.; Steinhardt, P.J.

    1999-01-01

    Recent observations suggest that a large fraction of the energy density of the Universe has negative pressure. One explanation is vacuum energy density; another is quintessence in the form of a scalar field slowly evolving down a potential. In either case, a key problem is to explain why the energy density nearly coincides with the matter density today. The densities decrease at different rates as the Universe expands, so coincidence today appears to require that their ratio be set to a specific, infinitesimal value in the early Universe. In this paper, we introduce the notion of a open-quotes tracker field,close quotes a form of quintessence, and show how it may explain the coincidence, adding new motivation for the quintessence scenario. copyright 1999 The American Physical Society

  18. Development of an analysis methodology applied to 4πβ-γ software coincidence data acquisition system

    International Nuclear Information System (INIS)

    Brancaccio, Franco; Dias, Mauro da Silva; Toledo, Fabio de

    2009-01-01

    The present work describes the new software methodology under development at the IPEN Nuclear Metrology Laboratory for radionuclide standardizations with 4πβ-γ coincidence technique. The software includes the Coincidence Graphic User Interface (GUI) and the Coincidence Analysis Program. The first results for a 60 Co sample measurement are discussed and compared to the results obtained with two different conventional coincidence systems. (author)

  19. Slow coincidences for CAMAC multiparameter analysis

    International Nuclear Information System (INIS)

    Akimov, Yu.K.; Kalinin, A.I.; Tissol'd, E.; Fromm, V.D.; Ekstein, P.

    1978-01-01

    A coincidence circuit with controlled parameters is described. The circuit has six coincidence inputs and one input for anticoincidences. A pulse duration in channels is changed from 0.25 to 5 μs and delay time, within 8 μs. The circuit is developed for multiparameter spectrometric analysis with the use of amplitude-digital and time-digital convertors. Its introduction permits one to diminish considerably the ''dead'' time of apparatus and to select rapidly and reliably strictly correlated digital information from convertors

  20. Reproduction of the coincidence effect in gamma ray spectrometry by using Monte Carlo method

    International Nuclear Information System (INIS)

    Park, S. H.; Kim, J. K.; Lee, S. H.

    2001-01-01

    Scintillation detector such as NaI(TI), or semiconductor detector, such as HPGe, are used for Measurement/Assessment of the radiation type and radiation activity. The measured energy spectrum are used for measuring the radiation type and activity. Corrections for true coincidence due to emit more than 2 photons at the same time and random coincidence due to measuring system when increasing of the radiation intensity. For accurate assessment, measurement with adequate measure system is performed, and corrections for coincidence are performed in the hardware aspect and software aspect. In general, there are limitations or difficulties in measurement of radiation assessment, computational simulation is instead used. In simulation, it has much advantages than measurement in technically, timely, and financially, it is widely used instead of measurement. In this study, the method to reproduce of the coincidence effect was proposed by using monte carlo method

  1. Coincidence-counting corrections for accidental coincidences, set dead time and intrinsic dead time

    International Nuclear Information System (INIS)

    Wyllie, H.A.

    1998-01-01

    An equation is derived for calculating the radioactivity of a source from the results of coincidence counting, taking into account dead-time losses and accidental coincidences. The corrections allow for the extension of the set dead time in the p channel by the intrinsic dead time. Experimental verification shows improvement over a previous equation. (author)

  2. Neutron coincidence counting with digital signal processing

    International Nuclear Information System (INIS)

    Bagi, Janos; Dechamp, Luc; Dransart, Pascal; Dzbikowicz, Zdzislaw; Dufour, Jean-Luc; Holzleitner, Ludwig; Huszti, Joseph; Looman, Marc; Marin Ferrer, Montserrat; Lambert, Thierry; Peerani, Paolo; Rackham, Jamie; Swinhoe, Martyn; Tobin, Steve; Weber, Anne-Laure; Wilson, Mark

    2009-01-01

    Neutron coincidence counting is a widely adopted nondestructive assay (NDA) technique used in nuclear safeguards to measure the mass of nuclear material in samples. Nowadays, most neutron-counting systems are based on the original-shift-register technology, like the (ordinary or multiplicity) Shift-Register Analyser. The analogue signal from the He-3 tubes is processed by an amplifier/single channel analyser (SCA) producing a train of TTL pulses that are fed into an electronic unit that performs the time- correlation analysis. Following the suggestion of the main inspection authorities (IAEA, Euratom and the French Ministry of Industry), several research laboratories have started to study and develop prototypes of neutron-counting systems with PC-based processing. Collaboration in this field among JRC, IRSN and LANL has been established within the framework of the ESARDA-NDA working group. Joint testing campaigns have been performed in the JRC PERLA laboratory, using different equipment provided by the three partners. One area of development is the use of high-speed PCs and pulse acquisition electronics that provide a time stamp (LIST-Mode Acquisition) for every digital pulse. The time stamp data can be processed directly during acquisition or saved on a hard disk. The latter method has the advantage that measurement data can be analysed with different values for parameters like predelay and gate width, without repeating the acquisition. Other useful diagnostic information, such as die-away time and dead time, can also be extracted from this stored data. A second area is the development of 'virtual instruments.' These devices, in which the pulse-processing system can be embedded in the neutron counter itself and sends counting data to a PC, can give increased data-acquisition speeds. Either or both of these developments could give rise to the next generation of instrumentation for improved practical neutron-correlation measurements. The paper will describe the

  3. Determination of microstructural parameters in damage models for ductile metals; Bestimmung von mikrostrukturellen Parametern in Schaedigungsmodellen fuer duktile Metalle

    Energy Technology Data Exchange (ETDEWEB)

    Steglich, D. [GKSS-Forschungszentrum Geesthacht GmbH (Germany). Inst. fuer Werkstofforschung

    1999-07-01

    For the determination of material parameters in micromechanical damage models the mechanical behaviour of representative volume elements of a two-phase material has been investigated and the phase morphology quantified by microstructural analysis. The material parameters have been successfully correlated to microstructural quantities and a prediction of the damage behaviour of structures is performed. Special emphasis is given to the model of Gurson, Tvergaard and Needleman, which has been used to predict the macroscopic behaviour of smooth tensile test specimens and the fracture resistance curves of bending specimens for two different materials, a nodular cast iron and a particle reinforced aluminium compound. (orig.) [German] Zur Bestimmung der Materialparameter in mikromechanischen Schaedigungsmodellen werden repraesentative Strukturelemente eines Werkstoffes untersucht und die Morphologie eines zweiphasigen Gefueges durch quantitative Gefuegeanalyse beschrieben. Mit dieser Strategie gelingen eine Identifikation der im Modell enthaltenen Parameter sowie die Vorhersage des Versagensverhaltens von Strukturen. Als mikromechanisches Materialmodell wird hauptsaechlich das Modell von Gurson, Tvergaard und Needleman verwendet. Seine Anwendbarkeit zur Vorhersage des globalen Verhaltens von glatten Zugproben und zur Simulation von Risswiderstandskurven wird bei zwei verschiedenen Werkstoffen gezeigt, einen Gusseisen und einem Aluminium-Verbundwerkstoff. (orig.)

  4. Coincidence imaging of polyatomic molecules via laser-induced Coulomb explosion

    International Nuclear Information System (INIS)

    Gagnon, J; Corkum, P B; Bhardwaj, V R; Lee, Kevin F; Rayner, D M

    2008-01-01

    We extend laser-induced Coulomb explosion imaging to retrieve the structure of the five-atom dichloromethane (CH 2 Cl 2 ) molecule by developing coincidence imaging and geometry optimization techniques. By detecting all five atoms in coincidence, we show that, from the measured velocity vectors, the geometry of the molecules can be reconstructed.

  5. Tachyon driven solution to Cosmic Coincidence Problrm

    OpenAIRE

    Srivastaca, S. K.

    2004-01-01

    Here, non-minimally coupled tachyon to gravity is considered as a source of "dark energy". It is demonstrated that with expansion of the universe, tachyon dark energy decays to "dark matter" providing a solution to "cosmic coincidence problem".Moreover, it is found that universe undergoes accelerated expansion simultaneously.

  6. High-level neutron coincidence counter (HLNCC): users' manual

    International Nuclear Information System (INIS)

    Krick, M.S.; Menlove, H.O.

    1979-06-01

    This manual describes the portable High-Level Neutron Coincidence Counter (HLNCC) developed at the Los Alamos Scientific Laboratory (LASL) for the assay of plutonium, particularly by inspectors of the International Atomic Energy Agency (IAEA). The counter is designed for the measurement of the effective 240 Pu mass in plutonium samples which may have a high plutonium content. The following topics are discussed: principle of operation, description of the system, operating procedures, and applications

  7. Quantifying radionuclide signatures from a γ–γ coincidence system

    International Nuclear Information System (INIS)

    Britton, Richard; Jackson, Mark J.; Davies, Ashley V.

    2015-01-01

    A method for quantifying gamma coincidence signatures has been developed, and tested in conjunction with a high-efficiency multi-detector system to quickly identify trace amounts of radioactive material. The γ–γ system utilises fully digital electronics and list-mode acquisition to time–stamp each event, allowing coincidence matrices to be easily produced alongside typical ‘singles’ spectra. To quantify the coincidence signatures a software package has been developed to calculate efficiency and cascade summing corrected branching ratios. This utilises ENSDF records as an input, and can be fully automated, allowing the user to quickly and easily create/update a coincidence library that contains all possible γ and conversion electron cascades, associated cascade emission probabilities, and true-coincidence summing corrected γ cascade detection probabilities. It is also fully searchable by energy, nuclide, coincidence pair, γ multiplicity, cascade probability and half-life of the cascade. The probabilities calculated were tested using measurements performed on the γ–γ system, and found to provide accurate results for the nuclides investigated. Given the flexibility of the method, (it only relies on evaluated nuclear data, and accurate efficiency characterisations), the software can now be utilised for a variety of systems, quickly and easily calculating coincidence signature probabilities. - Highlights: • Monte-Carlo based software developed to easily create/update a coincidence signal library for environmental radionuclides. • Coincidence library utilised to accurately quantify gamma coincidence signatures. • All coincidence signature probabilities are corrected for cascade summing, conversion electron emission and pair production. • Key CTBTO relevant radionuclides have been tested to verify the calculated correction factors. • Accurately quantifying coincidence signals during routine analysis will allow dramatically improved detection

  8. Dissociative photoionization of the NO molecule studied by photoelectron-photon coincidence technique

    International Nuclear Information System (INIS)

    Kivimaeki, A.; Alvarez-Ruiz, J.; Coreno, M.; Simone, M. de; Moise, A.; Partanen, L.; Richter, R.; Stankiewicz, M.

    2010-01-01

    Low-energy photoelectron-vacuum ultraviolet (VUV) photon coincidences have been measured using synchrotron radiation excitation in the inner-valence region of the nitric oxide molecule. The capabilities of the coincidence set-up were demonstrated by detecting the 2s -1 → 2p -1 radiative transitions in coincidence with the 2s photoelectron emission in Ne. In NO, the observed coincidence events are attributed to dissociative photoionization with excitation, whereby photoelectron emission is followed by fragmentation of excited NO + ions into O + + N* or N + + O* and VUV emission from an excited neutral fragment. The highest coincidence rate occurs with the opening of ionization channels which are due to correlation satellites of the 3σ photoionization. The decay time of VUV photon emission was also measured, implying that specific excited states of N atoms contribute significantly to observed VUV emission.

  9. Simplified slow anti-coincidence circuit for Compton suppression systems

    International Nuclear Information System (INIS)

    Al-Azmi, Darwish

    2008-01-01

    Slow coincidence circuits for the anti-coincidence measurements have been considered for use in Compton suppression technique. The simplified version of the slow circuit has been found to be fast enough, satisfactory and allows an easy system setup, particularly with the advantage of the automatic threshold setting of the low-level discrimination. A well-type NaI detector as the main detector surrounded by plastic guard detector has been arranged to investigate the performance of the Compton suppression spectrometer using the simplified slow circuit. The system has been tested to observe the improvement in the energy spectra for medium to high-energy gamma-ray photons from terrestrial and environmental samples

  10. Data Acquisition System for Electron Energy Loss Coincident Spectrometers

    International Nuclear Information System (INIS)

    Zhang Chi; Yu Xiaoqi; Yang Tao

    2005-01-01

    A Data Acquisition System (DAQ) for electron energy loss coincident spectrometers (EELCS) has been developed. The system is composed of a Multiplex Time-Digital Converter (TDC) that measures the flying time of positive and negative ions and a one-dimension position-sensitive detector that records the energy loss of scattering electrons. The experimental data are buffered in a first-in-first-out (FIFO) memory module, then transferred from the FIFO memory to PC by the USB interface. The DAQ system can record the flying time of several ions in one collision, and allows of different data collection modes. The system has been demonstrated at the Electron Energy Loss Coincident Spectrometers at the Laboratory of Atomic and Molecular Physics, USTC. A detail description of the whole system is given and experimental results shown

  11. Recent Advances in Digital Coincidence Counting for Radionuclide Metrology

    International Nuclear Information System (INIS)

    Keightley, John; Bobin, Christophe; Bouchard, Jacques; Capogni, Marco; Loreti, Stefano; Roteta, Miguel

    2013-06-01

    The radioactivity measurement techniques developed within the EURAMET EMRP 'MetroFission' Joint Research Project, were aimed at performing on-site activity measurements at the primary standard level (4πβ-γ coincidence counting) for a wide range of radionuclides utilizing recent advances in high-speed digital sampling and digital signal processing. The state-of-the-art technology employed within this project provides up to 14-bit digitizer systems operating with sampling rates in the order of 10 8 to 10 9 samples-per-second, incorporating on-board FPGA devices, which greatly enhances the application of digital signal processing for the implementation of digital coincidence counting. These devices when coupled to suitable analysis software, demonstrate a significant improvement in the provision of primary standards of radioactivity. This manuscript provides a description of the systems employed, along with recommendations regarding optimization of the digital sampling of signals from photo-multiplier tubes and pre-amplifiers and compare the benefits of 'off-line' versus 'on-line' 4πβ-γ digital coincidence counting systems. (authors)

  12. Method and apparstus for determining random coincidence count rate in a scintillation counter utilizing the coincidence technique

    International Nuclear Information System (INIS)

    Horrocks, D.L.

    1980-01-01

    A method and apparatus for the reliable determination of a random coincidence count attributable to chance coincidences of single-photon events which are each detected in only a single detector of a scintillation counter utilizing two detectors in a coincidence counting technique are described. A firstdelay device is employed to delay output pulses from one detector, and then the delayed signal is compared with the undelayed signal from the other detector in a coincidence circuit, to obtain an approximate random coincidence count. The output of the coincidence circuit is applied to an anti-coincidence circuit, where it is corrected by elimination of pulses coincident with, and attributable to, conventionally detected real coincidences, and by elimination of pulses coincident with, and attributable to, real coincidences that have been delayed by a second delay device having the same time parameter as the first. 8 claims

  13. Development of coincidence processing module for PEM

    International Nuclear Information System (INIS)

    Feng Baotong; Shuai Lei; Li Ke

    2011-01-01

    For the breast cancer diagnosis and therapy, a prototype of positron emission mammography (PEM) was developed in Institute of High Energy Physics, Chinese Academy of Sciences. In this paper, the design of coincidence processing module (CPM) for this PEM was presented. Both the hardware architecture and the software logic were introduced. In this design, the CPM used the Rocket IO fast interface in FPGA and fiber technology to acquire the preprocessed data from the continuous sampling module (CSM) and then selected the valid event with the coincidence timing window method, which was performed in the FPGA on the daughter board. The CPM transmits the processed data to host computer via gigabit Ethernet. The whole system was controlled by CAN bus. The primary tests indicate that the performance of this design is good. (authors)

  14. Recent progress with digital coincidence counting

    International Nuclear Information System (INIS)

    Butcher, K.S.A.; Watt, G.C.; Alexiev, D.

    1999-01-01

    Digital Coincidence Counting (DCC) is a new technique, based on the older method of analogue coincidence counting. It has been developed by ANSTO as a faster more reliable means of determining the activity of ionising radiation samples. The technique employs a dual channel analogue to digital converter acquisition system for collecting pulse information from a 4Π beta detector and a NaI(Tl) gamma detector. The digitised pulse information is stored on a high speed hard disk and timing information for both channels is also stored. The data may subsequently be recalled and analysed using software based algorithms. The system is operational and results are now being routinely collected and analysed. Some of the early work is presented for Co-60, Na-22 and Sm-153

  15. New way on designing majorant coincidence circuits

    International Nuclear Information System (INIS)

    Gajdamaka, R.I.; Kalinnikov, V.A.; Nikityuk, N.M.; Shirikov, V.P.

    1982-01-01

    A new way of designing fast devices of combinatorial selection by the number of particles passing through a multichannel charged particle detector is decribed. The algorithm of their operation is based on modern algebraic coding theory. By application of analytical computational methods Boolean expressions can be obtianed for designing basic circuits for a large number of inputs. An example of computation of 15 inputs majorant coincidence circuit is considered

  16. Coincident-inclusive electrofission angular correlations

    International Nuclear Information System (INIS)

    Arruda Neto, J.D.T.

    1983-08-01

    A method for the joint analysis of coincident and inclusive electrofission data, in order to minimize effects of the model dependence of data interpretation, is developed. Explicit calculations of the (e,e'f) angular correlations are presented. The potentialities of the method to the study of sub- and near-barrier properties of the fission process, and to the study of the giant resonances fission mode, are discussed. (Author) [pt

  17. A coincidence study between photo- and Auger electrons

    International Nuclear Information System (INIS)

    Ricz, S.; Koever, A.; Varga, D.; Molnar, J.; Aksela, S.; Jurvansuu, M.

    2000-01-01

    Complete text of publication follows. The investigation of double differential cross sections of photon induced Auger electrons provides very sensitive method for studying the rearrangement process, especially when the angular correlation between photo- and Auger electrons is also studied. Such type of measurements could reveal a new aspect in studying the electron-electron, hole-electron and photoelectron - Auger electron interactions. It enables one to separate the overlapping Auger lines belonging to different initial holes. The traditional coincidence measurement is very time consuming and causes serious calibration problems. In order to overcome these experimental difficulties a new electron-spectrometer (ESA-22) was developed in ATOMKI, Debrecen in cooperation with the Electron spectroscopy group of University of Oulu, Finland. The analyzer consists of a spherical and a cylindrical part. It is very similar to the ESA-21 analyzer. The main differences is that the focal ring can be set different diameters thus either a series of channel detectors can be used to detect the electrons at different angles or a position sensitive channel plate can be applied for simultaneous angular recording of electrons. Furthermore the outer sphere and cylinder are cut into two parts so the spectrometer is capable to analyze two independent angularly resolved electron spectra (in the 0 deg - 180 deg region) at different energy regions, simultaneously. A special electronic control and data handling electronics and software was worked out to control the analyzer. The first results were presented in. In the last year the ESA-22 electron-spectrometer was transported to the I411 beam line of MAX-II synchrotron in Lund, Sweden. The advanced properties of the spectrometer was investigated by measuring coincidences between the photoelectrons originated from the Ar L 3 subshell and the Ar Auger electrons in the 203-207 eV energy region. Fig. 1 shows the single and the coincidence spectra

  18. Evaluation of accidental coincidences for time-differential Moessbauer-spectroscopy

    International Nuclear Information System (INIS)

    Alflen, M.; Meyer, W.

    1995-01-01

    The accidental coincidences of a measuring system based on time-to-amplitude conversion are considered in some detail for the case of low starting and high stopping rates. Two types of accidental coincidences are distinguished, those carrying time information and those without time information. Neglecting any deadtime effects of the detectors, analytical expressions for the calculation of the time distribution of the random coincidences are evaluated. The analytical expressions have been confirmed by Monte Carlo simulations. The procedure is applied to time-differential Moessbauer spectroscopy in order to extract the time spectra of true coincidences. The measured spectrum in a time channel turns out to be a superposition of the true spectrum (true coincidences), a time integral spectrum (random coincidences), and a weighted superposition of true spectra of other time channels (random but time carrying information). A measurement with a single line 57 Co/Rh-source and single line K[Fe(CN) 6 ].3H 2 O-absorber with stopping rates of 1 MBq shows agreement between the theoretical time-filtered spectra and the corrected measured spectra of true coincidences. ((orig.))

  19. Standardization of 18F by coincidence and LSC methods

    International Nuclear Information System (INIS)

    Roteta, Miguel; Garcia-Torano, Eduardo; Rodriguez Barquero, Leonor

    2006-01-01

    The nuclide 18 F disintegrates to 18 O by β + emission (96.86%) and electron capture (3.14%) with a half-life of 1.8288 h. It is widely used in nuclear medicine for positron emission tomography (PET). A radioactive solution of this nuclide has been standardized by two techniques: coincidence measurements with a pressurized proportional counter and liquid scintillation counting using the CIEMAT/NIST method. One ampoule containing a solution calibrated in activity was sent for measurement at the International Reference System maintained by the BIPM. Results are in excellent agreement with SIR values

  20. X-ray line coincidence photopumping in a solar flare

    Science.gov (United States)

    Keenan, F. P.; Poppenhaeger, K.; Mathioudakis, M.; Rose, S. J.; Flowerdew, J.; Hynes, D.; Christian, D. J.; Nilsen, J.; Johnson, W. R.

    2018-03-01

    Line coincidence photopumping is a process where the electrons of an atomic or molecular species are radiatively excited through the absorption of line emission from another species at a coincident wavelength. There are many instances of line coincidence photopumping in astrophysical sources at optical and ultraviolet wavelengths, with the most famous example being Bowen fluorescence (pumping of O III 303.80 Å by He II), but none to our knowledge in X-rays. However, here we report on a scheme where a He-like line of Ne IX at 11.000 Å is photopumped by He-like Na X at 11.003 Å, which predicts significant intensity enhancement in the Ne IX 82.76 Å transition under physical conditions found in solar flare plasmas. A comparison of our theoretical models with published X-ray observations of a solar flare obtained during a rocket flight provides evidence for line enhancement, with the measured degree of enhancement being consistent with that expected from theory, a truly surprising result. Observations of this enhancement during flares on stars other than the Sun would provide a powerful new diagnostic tool for determining the sizes of flare loops in these distant, spatially unresolved, astronomical sources.

  1. Importance of interpolation and coincidence errors in data fusion

    Directory of Open Access Journals (Sweden)

    S. Ceccherini

    2018-02-01

    Full Text Available The complete data fusion (CDF method is applied to ozone profiles obtained from simulated measurements in the ultraviolet and in the thermal infrared in the framework of the Sentinel 4 mission of the Copernicus programme. We observe that the quality of the fused products is degraded when the fusing profiles are either retrieved on different vertical grids or referred to different true profiles. To address this shortcoming, a generalization of the complete data fusion method, which takes into account interpolation and coincidence errors, is presented. This upgrade overcomes the encountered problems and provides products of good quality when the fusing profiles are both retrieved on different vertical grids and referred to different true profiles. The impact of the interpolation and coincidence errors on number of degrees of freedom and errors of the fused profile is also analysed. The approach developed here to account for the interpolation and coincidence errors can also be followed to include other error components, such as forward model errors.

  2. Simulation approach to coincidence summing in {gamma}-ray spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Dziri, S., E-mail: samir.dziri@iphc.cnrs.fr [Groupe RaMsEs, Institut Pluridisciplinaire Hubert Curien (IPHC), University of Strasbourg, CNRS, IN2P3, UMR 7178, 23 rue de Loess, BP 28, 67037 Strasbourg Cedex 2 (France); Nourreddine, A.; Sellam, A.; Pape, A.; Baussan, E. [Groupe RaMsEs, Institut Pluridisciplinaire Hubert Curien (IPHC), University of Strasbourg, CNRS, IN2P3, UMR 7178, 23 rue de Loess, BP 28, 67037 Strasbourg Cedex 2 (France)

    2012-07-15

    Some of the radionuclides used for efficiency calibration of a HPGe spectrometer are subject to coincidence-summing (CS) and account must be taken of the phenomenon to obtain quantitative results when counting samples to determine their activity. We have used MCNPX simulations, which do not take CS into account, to obtain {gamma}-ray peak intensities that were compared to those observed experimentally. The loss or gain of a measured peak intensity relative to the simulated peak is attributed to CS. CS correction factors are compared with those of ETNA and GESPECOR. Application to a test sample prepared with known radionuclides gave values close to the published activities. - Highlights: Black-Right-Pointing-Pointer Coincidence summing occurs when the solid angle is increased. Black-Right-Pointing-Pointer The loss of counts gives rise to an approximative efficiency curves, this means a wrong quantitative data. Black-Right-Pointing-Pointer To overcome this problem we need mono-energetic source, otherwise, the MCNPX simulation allows by comparison with the experiment data to get the coincidence summing correction factors. Black-Right-Pointing-Pointer By multiplying these factors by the approximative efficiency, we obtain the accurate efficiency.

  3. Einige Überlegungen zur Bestimmung des Äquivalenzgrades am Beispiel des lexikalischen Feldes „Erhebung im Gelände“

    Directory of Open Access Journals (Sweden)

    Daumantas Katinas

    2013-12-01

    Full Text Available Eine der wichtigsten Fragen in der kontrastiven Lexikologie, zweisprachigen Lexikografie und der Übersetzungswissenschaft ist die Bestimmung des Äquivalenzgrades zwischen den Lexemen der Vergleichssprachen. Die meisten Lexikologen, die sich mit kontrastiven Untersuchungen beschäftigen, sprechen von der Voll-, Teil- und Nulläquivalenz. In der Praxis existiert allerdings nur die so genannte Teiläquivalenz. Wenn man aber in der wissenschaftlichen Diskussion nur diesen Begriff verwenden würde, entstünden somit noch größere Schwierigkeiten bei der Bestimmung des Äquivalenzgrades, weil sich das Spektrum der Teiläquivalenz von 1 bis 99 Prozent erstrecken würde. Daher wird im vorliegenden Beitrag eine Formel zur Berechnung des Äquivalenzgrades zwischen zwei Vergleichslexemen vorgeschlagen. In erster Linie wird die semantische Analyse des lexikalischen Feldes „Erhebung im Gelände“ im Litauischen und im Deutschen, das die Grundlage der Formel bildet, kurz präsentiert. Dazu wird der von Helmut Henne und Herbert Ernst Wiegand (Henne 1972, Wiegand 1970, Kühn 1979 vorgeschlagene Entwurf, die lexikalische Bedeutung mit Hilfe von onomasiologischen, komplementär-semasiologischen und autonom-semasiologischen Operationsschritten zu beschreiben, herangezogen. Dieser Entwurf wird durch kontrastive, prototypensemantische und korpusgestützte Aspekte ergänzt. Im zweiten Teil wird die mathematische Formel zur Berechnung des Äquivalenzgrades zwischen zwei Vergleichslexemen angegeben und durch das Beispiel des Lexempaars kalva–Hügel veranschaulicht.

  4. It Takes Two – Coincidence coding within the dual olfactory pathway of the honeybee

    Directory of Open Access Journals (Sweden)

    Martin F. Brill

    2015-07-01

    Full Text Available To rapidly process biologically relevant stimuli, sensory systems have developed a broad variety of coding mechanisms like parallel processing and coincidence detection. Parallel processing (e.g. in the visual system, increases both computational capacity and processing speed by simultaneously coding different aspects of the same stimulus. Coincidence detection is an efficient way to integrateinformation from different sources. Coincidence has been shown to promote associative learning and memory or stimulus feature detection (e.g. in auditory delay lines. Within the dual olfactory pathway of the honeybee both of these mechanisms might be implemented by uniglomerular projection neurons (PNs that transfer information from the primary olfactory centers, the antennal lobe (AL, to a multimodal integration center, the mushroom body (MB. PNs from anatomically distinct tracts respond to the same stimulus space, but have different physiological properties, characteristics that are prerequisites for parallel processing of different stimulus aspects. However, the PN pathways also display mirror-imaged like anatomical trajectories that resemble neuronal coincidence detectors as known from auditory delay lines. To investigate temporal processing of olfactory information, we recorded PN odor responses simultaneously from both tracts and measured coincident activity of PNs within and between tracts. Our results show that coincidence levels are different within each of the two tracts. Coincidence also occurs between tracts, but to a minor extent compared to coincidence within tracts. Taken together our findings support the relevance of spike timing in coding of olfactory information (temporal code.

  5. It takes two-coincidence coding within the dual olfactory pathway of the honeybee.

    Science.gov (United States)

    Brill, Martin F; Meyer, Anneke; Rössler, Wolfgang

    2015-01-01

    To rapidly process biologically relevant stimuli, sensory systems have developed a broad variety of coding mechanisms like parallel processing and coincidence detection. Parallel processing (e.g., in the visual system), increases both computational capacity and processing speed by simultaneously coding different aspects of the same stimulus. Coincidence detection is an efficient way to integrate information from different sources. Coincidence has been shown to promote associative learning and memory or stimulus feature detection (e.g., in auditory delay lines). Within the dual olfactory pathway of the honeybee both of these mechanisms might be implemented by uniglomerular projection neurons (PNs) that transfer information from the primary olfactory centers, the antennal lobe (AL), to a multimodal integration center, the mushroom body (MB). PNs from anatomically distinct tracts respond to the same stimulus space, but have different physiological properties, characteristics that are prerequisites for parallel processing of different stimulus aspects. However, the PN pathways also display mirror-imaged like anatomical trajectories that resemble neuronal coincidence detectors as known from auditory delay lines. To investigate temporal processing of olfactory information, we recorded PN odor responses simultaneously from both tracts and measured coincident activity of PNs within and between tracts. Our results show that coincidence levels are different within each of the two tracts. Coincidence also occurs between tracts, but to a minor extent compared to coincidence within tracts. Taken together our findings support the relevance of spike timing in coding of olfactory information (temporal code).

  6. Coincidence logic modules for criticality alarming

    International Nuclear Information System (INIS)

    Schaief, C.C. III.

    1977-04-01

    A coincidence Logic Module and a companion contact closure Relay Module utilizing the NIM Standard have been developed for criticality alarming. The units provide an ALARM whenever two or more out of N detectors become activated. In addition, an ALERT is generated whenever one or more detectors is activated or when certain electronic component failures occur. The number of detector inputs (N) can be expanded in groups of six by adding modules. Serial and parallel redundancy were used to reduce the probability of system failure

  7. Experimental Measurement of the Ratio of the Reaction Cross Section (n,2n) for the Natural Mixtures of Lead and Iron Isotopes with 14 MeV Neutrons by the Method of Moderated Neutron-Neutron Coincidences

    International Nuclear Information System (INIS)

    Panteleev, Ts.Ts.; Penchev, O.I.; Trifonov, A.I.; Troshev, T.M.; Christov, V.I.

    1986-01-01

    Neutron data are widely applied in nuclei physics and into practice as well. Data obtained by means of different measurement methods are of interest for increasing the accuracy and reliability of the recommended values for the cross sections of neutron interactions, with substance. The activation analysis method gives a possibility to obtain data about cross section interactions of 14 MeV neutrons with the nuclei σ (n,2n), σ( n,p), σ (n,pn), σ (n,α), etc. A serious shortcoming of this measuring method is the necessity of applying express methods of analysis of induced activities - restrictions connected with the life-times of the reaction products. It is also necessary to comply with the requirements for high accuracy in the data about the decay schemes and the absolute intensities of the γ-transitions in the investigated nuclei. The investigations directly measuring the output of the reaction, products from the targets, placed into the neutron beam, do not possess the shortcomings of the activation method but require serious demands toward the detecting apparatuses (ionization chambers, semiconducting and scintillation detectors, proportional counters, etc.). These demands are connected with the heavy background conditions of work at the beams for measurements of whatever partial cross sections. During the experimental measurements of the reactions by neutron emission for registration, it is necessary to slow them down to thermal energies, since only in this energy interval there exist sufficiently effective without threshold detectors. We have elaborated the experimental set-up allowing to measure the neutron multiplicity in an interaction. In the present work we have also used it for a relative measurement the the reaction cross section σ (n,2n) for Pe and Pb nuclei in their natural isotope mixtures. As it is known, this reaction has an important application for the blanket materials of thermonuclear reactors and for tritium fuel regeneration problem. The

  8. Monte Carlo calculations of the neutron coincidence gate utilisation factor for passive neutron coincidence counting

    CERN Document Server

    Bourva, L C A

    1999-01-01

    The general purpose neutron-photon-electron Monte Carlo N-Particle code, MCNP sup T sup M , has been used to simulate the neutronic characteristics of the on-site laboratory passive neutron coincidence counter to be installed, under Euratom Safeguards Directorate supervision, at the Sellafield reprocessing plant in Cumbria, UK. This detector is part of a series of nondestructive assay instruments to be installed for the accurate determination of the plutonium content of nuclear materials. The present work focuses on one aspect of this task, namely, the accurate calculation of the coincidence gate utilisation factor. This parameter is an important term in the interpretative model used to analyse the passive neutron coincidence count data acquired using pulse train deconvolution electronics based on the shift register technique. It accounts for the limited proportion of neutrons detected within the time interval for which the electronics gate is open. The Monte Carlo code MCF, presented in this work, represents...

  9. Bell's inequalities and the four-coincidence experiment

    International Nuclear Information System (INIS)

    Garuccio, A.; Rapisarda, V.A.

    1981-01-01

    The four-coincidence experiment, in which two correlated particles interact, each, with a dichotomic-detection apparatus, is formally described. Some care is devoted to analyze what is due to the structure of the experiment, and what can really be measured. Some of the questions which the experiment can answer are posed in a general probabilistic hidden-variable frame and, for the QM point of view, in the specific case of the 0-1-0 calcium atomic cascade. Besides, a new method to treat discriminating inequalities is shown which allows, in our opinion, a deeper insight into the theoretical assumptions together with a better experimental reliability. (author)

  10. Coincidence corrected efficiency calibration of Compton-suppressed HPGe detectors

    Energy Technology Data Exchange (ETDEWEB)

    Aucott, Timothy [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Brand, Alexander [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); DiPrete, David [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2015-04-20

    The authors present a reliable method to calibrate the full-energy efficiency and the coincidence correction factors using a commonly-available mixed source gamma standard. This is accomplished by measuring the peak areas from both summing and non-summing decay schemes and simultaneously fitting both the full-energy efficiency, as well as the total efficiency, as functions of energy. By using known decay schemes, these functions can then be used to provide correction factors for other nuclides not included in the calibration standard.

  11. Preliminary results of a neutron-gamma coincidence experiment

    International Nuclear Information System (INIS)

    Piercey, R.B.; Dunnam, F.E.; Muga, M.L.; Rester, A.C.; Ramayya, A.V.; Hamilton, J.H.; Eberth, J.; Zganjar, E.F.

    1984-01-01

    The recently completed neutron multiplicity detector dubbed PANDA (Pentagonal Annular Neutron Detector Array) is fully described later in this report. The new detector was recently used for the first time on-line at the Holifield Heavy Ion Research Facility to measure neutron-gamma coincidence in the 24 Mg( 58 Ni,xαypzn) reaction. The detector configuration for the experiment is shown. The PANDA was situated in the forward direction, coaxial to the beam line with five gamma-ray detectors placed at +/- 90 0 , +/- 135 0 , and 0 0 . 2 figures

  12. Sub-nanosecond Half-life Measurement of the Yrast I{sup π}=5{sup −} State in the N=78 Nucleus {sup 136}{sub 58}Ce using Fast-timing Coincident Gamma-ray Spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Alharbi, T. [Department of Physics, University of Surrey, Guildford, GU2 7XH (United Kingdom); Department of Physics, Faculty of Science in Zulfi, Almajmaah University, P.O. Box 1712, 11932 (Saudi Arabia); Regan, P.H., E-mail: p.regan@surrey.ac.uk [Department of Physics, University of Surrey, Guildford, GU2 7XH (United Kingdom); National Physical Laboratory, Teddington, Middlesex, TW11 0LW (United Kingdom); Mărginean, N. [Horia Hulubei – National Institute for Physics and Nuclear Engineering (IFIN-HH), Bucharest (Romania); Podolyák, Zs.; Bajoga, A.; Britton, R. [Department of Physics, University of Surrey, Guildford, GU2 7XH (United Kingdom); Bucurescu, D.; Deleanu, D.; Filipescu, D.; Ghită, D.; Glodariu, T.; Mihai, C. [Horia Hulubei – National Institute for Physics and Nuclear Engineering (IFIN-HH), Bucharest (Romania); Mulholland, K. [School of Engineering, University of the West of Scotland, High Street, Paisley PA1 2BE (United Kingdom); Mărginean, R.; Negret, A.; Nita, C.R. [Horia Hulubei – National Institute for Physics and Nuclear Engineering (IFIN-HH), Bucharest (Romania); Patel, Z. [Department of Physics, University of Surrey, Guildford, GU2 7XH (United Kingdom); Roberts, O.J. [School of Computing Engineering and Mathematics, University of Brighton, Brighton, BN2 4GJ (United Kingdom); Stroe, L.; Sava, T. [Horia Hulubei – National Institute for Physics and Nuclear Engineering (IFIN-HH), Bucharest (Romania); and others

    2014-06-15

    We report on the measurement of the half-life of the yrast I{sup π}=5{sup −} state in the transitional nucleus {sup 136}Ce using a combined HPGe-LaBr3(Ce) scintillator gamma-ray detection array. The measured value for the E1 decay is approximately half a nanosecond, which corresponds to an E1 decay strength of approximately 2×10{sup −6} Wu. This value is in line with single-particle type E1 decays in this mass region and suggests no sign of additional K-hindrance associated with axially symmetric quadrupole deformations observed for lighter cerium isotopes.

  13. The IAEA neutron coincidence counting (INCC) and the DEMING least-squares fitting programs

    International Nuclear Information System (INIS)

    Krick, M.S.; Harker, W.C.; Rinard, P.M.; Wenz, T.R.; Lewis, W.; Pham, P.; Ridder, P. de

    1998-01-01

    Two computer programs are described: (1) the INCC (IAEA or International Neutron Coincidence Counting) program and (2) the DEMING curve-fitting program. The INCC program is an IAEA version of the Los Alamos NCC (Neutron Coincidence Counting) code. The DEMING program is an upgrade of earlier Windows reg-sign and DOS codes with the same name. The versions described are INCC 3.00 and DEMING 1.11. The INCC and DEMING codes provide inspectors with the software support needed to perform calibration and verification measurements with all of the neutron coincidence counting systems used in IAEA inspections for the nondestructive assay of plutonium and uranium

  14. Performance of a coincidence based blood activity monitor

    International Nuclear Information System (INIS)

    Moses, W.W.

    1989-12-01

    A new device has been constructed that measures the positron emitting radio-tracer concentration in arterial blood by extracting blood with a peristaltic pump, then measuring the activity concentration by detecting coincident pairs of 511 keV photons with a pair of heavy inorganic scintillators attached to photomultiplier tubes. The sensitivity of this device is experimentally determined to be 610 counts/second per μCi/ml, and has a paralyzing dead time of 1.2 μs, so is capable of measuring blood activity concentration as high as 1 mCi/ml. Its performance is compared to two other blood monitoring methods: discrete blood samples counted with a well counter and device that uses a plastic scintillator to directly detect positrons. The positron detection efficiency of this device for 18 F is greater than the plastic scintillation counter, and also eliminates the radioisotope dependent correction factors necessary to convert count rate to absolute concentration. Coincident photon detection also has the potential of reducing the background compared to direct positron detection, thereby increasing the minimum detectable isotope concentration. 10 refs., 6 figs

  15. Calibration of nuclides by gamma-gamma sum peak coincidence counting

    International Nuclear Information System (INIS)

    Guevara, E.A.

    1986-01-01

    The feasibility of extending sum peak coincidence counting to the direct calibration of gamma-ray emitters having particular decay schemes was investigated, also checkings of the measurement accuracy, by comparing with more precise beta-gamma coincidence counting have been performed. New theoretical studies and experiments were developed, demonstrating the reliability of the procedure. Uncertainties of less than one percent were obtained when certain radioactive sources were measured. The application of the procedure to 60 Co, 22 Na, 47 Ca and 148 Pm was studied. Theoretical bases of sum peak coincidence counting were set in order to extend it as an alternative method for absolute activity determination. In this respect, theoretical studies were performed for positive and negative beta decay, and electron capture, either accompanied or unaccompanied by coincident gamma rays. They include decay schemes containing up to three daughter nuclide excited levels, for different geometrical configurations. Equations are proposed for a possible generalization of the procedure. (M.E.L.) [es

  16. Coincident Detection Significance in Multimessenger Astronomy

    Science.gov (United States)

    Ashton, G.; Burns, E.; Dal Canton, T.; Dent, T.; Eggenstein, H.-B.; Nielsen, A. B.; Prix, R.; Was, M.; Zhu, S. J.

    2018-06-01

    We derive a Bayesian criterion for assessing whether signals observed in two separate data sets originate from a common source. The Bayes factor for a common versus unrelated origin of signals includes an overlap integral of the posterior distributions over the common-source parameters. Focusing on multimessenger gravitational-wave astronomy, we apply the method to the spatial and temporal association of independent gravitational-wave and electromagnetic (or neutrino) observations. As an example, we consider the coincidence between the recently discovered gravitational-wave signal GW170817 from a binary neutron star merger and the gamma-ray burst GRB 170817A: we find that the common-source model is enormously favored over a model describing them as unrelated signals.

  17. A generalized model for coincidence counting

    International Nuclear Information System (INIS)

    Lu, Ming-Shih; Teichmann, T.

    1992-01-01

    The aim of this paper is to provide a description of the multiplicative processes associated with coincidence counting techniques, for example in the NDA of plutonium bearing materials. The model elucidates both the physical processes and the underlying mathematical formalism in a relatively simple but comprehensive way. In particular, it includes the effect of absorption by impurities or poisons, as well as that of neutron leakage on a parallel basis to the treatment of induced fission itself. The work thus parallels and generalizes the methods of Boehnel of Hage and Cifarelli, and more recently of Yanjushkin. This paper introduces the concept of a dual probability generating function to account for both the basic physical multiplication phenomena, as well as the detection phenomena. The underlying approach extends the idea of a simple probability generating function, due to De Moivre. The basic mathematical background may be found, for example, in Feller 1966

  18. Electron-electron coincidence spectroscopies at surfaces

    International Nuclear Information System (INIS)

    Stefani, G.; Iacobucci, S.; Ruocco, A.; Gotter, R.

    2002-01-01

    In the past 20 years, a steadily increasing number of electron-electron coincidence experiments on atoms and molecules have contributed to a deeper understanding of electron-electron correlation effects. In more recent years this technique has been extended to the study of solid surfaces. This class of one photon IN two electrons OUT experiments will be discussed with an emphasis on grazing incidence geometry, that is expected to be particularly suited for studying surfaces. The crucial question of which is the dominant mechanism that leads to ejection of pairs of electron from the surface will be addressed. It will be shown that, depending on the kinematics chosen, the correlated behaviour of the pairs of electrons detected might be singled out from independent particle one

  19. Tight bounds for the Pearle-Braunstein-Caves chained inequality without the fair-coincidence assumption

    Science.gov (United States)

    Jogenfors, Jonathan; Larsson, Jan-Åke

    2017-08-01

    In any Bell test, loopholes can cause issues in the interpretation of the results, since an apparent violation of the inequality may not correspond to a violation of local realism. An important example is the coincidence-time loophole that arises when detector settings might influence the time when detection will occur. This effect can be observed in many experiments where measurement outcomes are to be compared between remote stations because the interpretation of an ostensible Bell violation strongly depends on the method used to decide coincidence. The coincidence-time loophole has previously been studied for the Clauser-Horne-Shimony-Holt and Clauser-Horne inequalities, but recent experiments have shown the need for a generalization. Here, we study the generalized "chained" inequality by Pearle, Braunstein, and Caves (PBC) with N ≥2 settings per observer. This inequality has applications in, for instance, quantum key distribution where it has been used to reestablish security. In this paper we give the minimum coincidence probability for the PBC inequality for all N ≥2 and show that this bound is tight for a violation free of the fair-coincidence assumption. Thus, if an experiment has a coincidence probability exceeding the critical value derived here, the coincidence-time loophole is eliminated.

  20. Minicomputer system for radiochemical analysis by coincidence spectrometry

    International Nuclear Information System (INIS)

    Brauer, F.P.; Fager, J.E.

    1979-01-01

    Minicomputer-based coincidence analysis methods have been developed for use in performing radiochemical analysis by high-resolution x- and gamma-ray coincidence spectrometry. This paper describes the data-acquisition and analysis methods develolped for qualitative and quantitative analyses of coincidence spectrometric data. Data-acquisition capabilities include both direct multiparameter pulse-height analysis and buffered list-mode acquisition

  1. Neutron coincidence counter for MOX fuel pins in storage trays: users' manual

    International Nuclear Information System (INIS)

    Cowder, L.; Menlove, H.

    1982-08-01

    The neutron coincidence counter for measurement of mixed-oxide fuel pins in storage trays is described. The special detector head has been designed so that the detectors, high-voltage junction boxes, and electronics are interchangeable with those of the high-level neutron coincidence counter system. This manual describes the system components and the operation and maintenance of the counter. The counter was developed at Los Alamos National Laboratory for in-plant inspection applications by the International Atomic Energy Agency

  2. Imaging photoelectron photoion coincidence spectroscopy with velocity focusing electron optics

    International Nuclear Information System (INIS)

    Bodi, Andras; Johnson, Melanie; Gerber, Thomas; Gengeliczki, Zsolt; Sztaray, Balint; Baer, Tomas

    2009-01-01

    An imaging photoelectron photoion coincidence spectrometer at the vacuum ultraviolet (VUV) beamline of the Swiss Light Source is presented and a few initial measurements are reported. Monochromatic synchrotron VUV radiation ionizes the cooled or thermal gas-phase sample. Photoelectrons are velocity focused, with better than 1 meV resolution for threshold electrons, and also act as start signal for the ion time-of-flight analysis. The ions are accelerated in a relatively low, 40-80 V cm -1 field, which enables the direct measurement of rate constants in the 10 3 -10 7 s -1 range. All electron and ion events are recorded in a triggerless multiple-start/multiple-stop setup, which makes it possible to carry out coincidence experiments at >100 kHz event frequencies. As examples, the threshold photoelectron spectrum of the argon dimer and the breakdown diagrams for hydrogen atom loss in room temperature methane and the chlorine atom loss in cold chlorobenzene are shown and discussed.

  3. Soudan 2 muons in coincidence with BATSE bursts

    International Nuclear Information System (INIS)

    DeMuth, D.M.; Marshak, M.L.; Wagner, G.L.

    1994-01-01

    We explore the possibilities of statistically significant temporal and spatial coincidences between underground muons at Soudan 2 and Gamma Ray Bursts at the GRO-BATSE detector. Our search uses data from the April 91 to March 92 BATSE burst catalog to seek correlations within a 100 second window of coincidence. Sixteen of 180 BATSE triggers have temporally and spatially coincident muons in the Soudan 2 detector. We estimate the chance probability of each coincidence assuming the null hypothesis on the basis of a study of the multiplicities of spatially coincident muons observed over a two day period centered on the time of burst

  4. X-ray fluorescence/Auger-electron coincidence spectroscopy of vacancy cascades in atomic argon

    International Nuclear Information System (INIS)

    Arp, U.

    1996-01-01

    Argon L 2.3 -M 2.3 M 2.3 Auger-electron spectra were measured in coincidence with Kα fluorescent x-rays in studies of Ar K-shell vacancy decays at several photon energies above the K-threshold and on the 1s-4p resonance in atomic argon. The complex spectra recorded by conventional electron spectroscopy are greatly simplified when recorded in coincidence with fluorescent x-rays, allowing a more detailed analysis of the vacancy cascade process. The resulting coincidence spectra are compared with Hartree-Fock calculations which include shake-up transitions in the resonant case. Small energy shifts of the coincidence electron spectra are attributed to post-collision interaction with 1s photoelectrons

  5. Study and development of a spectrometer with Compton suppression and gamma coincidence counting

    International Nuclear Information System (INIS)

    Masse, D.

    1990-10-01

    This paper presents the characteristics of a spectrometer consisting of a Ge detector surrounded by a NaI(T1) detector that can operate in Compton-suppression and gamma-gamma coincidence modes. The criteria that led to this measurement configuration are discussed and the spectrometer performances are shown for 60 Co and 137 Cs gamma-ray sources. The results for the measurement of 189 Ir (Compton suppression) and for the measurement of 101 Rh (gamma-gamma coincidence) in the presence of other radioisotopes are given. 83 Rb and 105 Ag isotopes are also measured with this spectrometer [fr

  6. Determination of the thermophysical properties of loose rocks; Bestimmung der thermophysikalischen Kennwerte von Lockergesteinen

    Energy Technology Data Exchange (ETDEWEB)

    Stegner, Johannes; Seehaus, Rainer; Sass, Ingo [Technische Univ. Darmstadt (Germany). Fachgebiet Angewandte Geothermie

    2012-10-16

    The heat conductivity as well as the temperature conductivity of loose rocks are the most important properties for the quantification of the yields of near-surface geothermal power plants. The more details on the heat conductivity are available, the more economical and sustainable is the dimensioning of a plant. The heat conductivity of loose rocks depends on the heat conductivity of the individual grain size fractions, water content, air pore volume, dry density, pressure conditions and temperature. Actually, a standardized procedure for the determination of geothermal parameters is missing. Thus, a measurement device for the investigation of the heat conductivity and thermal conductivity is developed. This measurement device enables a reproducible investigation of loose rocks optionally at a pressure consistency of up to 7.6 MPa, or at a volume consistency in the temperature range from -10 to +80 Celsius. The functionality of this measurement device can be validated by means of a comparison of measurements and finite element method simulations using loose rock standards. Additionally, the results of the field tests were correlated with in-situ values. In addition to validation of measurement devices, the measurement results are used to create calculation models for the geothermal parameters of loose rocks based on soil mechanical properties.

  7. K-chameleon and the coincidence problem

    International Nuclear Information System (INIS)

    Wei Hao; Cai Ronggen

    2005-01-01

    In this paper we present a hybrid model of k-essence and chameleon, named as k-chameleon. In this model, due to the chameleon mechanism, the directly strong coupling between the k-chameleon field and matters (cold dark matters and baryons) is allowed. In the radiation-dominated epoch, the interaction between the k-chameleon field and background matters can be neglected; the behavior of the k-chameleon therefore is the same as that of the ordinary k-essence. After the onset of matter domination, the strong coupling between the k-chameleon and matters dramatically changes the result of the ordinary k-essence. We find that during the matter-dominated epoch, only two kinds of attractors may exist: one is the familiar K attractor and the other is a completely new, dubbed C attractor. Once the Universe is attracted into the C attractor, the fraction energy densities of the k-chameleon Ω φ and dust matter Ω m are fixed and comparable, and the Universe will undergo a power-law accelerated expansion. One can adjust the model so that the K attractor does not appear. Thus, the k-chameleon model provides a natural solution to the cosmological coincidence problem

  8. Coincidence orientations of grains in hexagonal materials

    International Nuclear Information System (INIS)

    Grimmer, H.; Warrington, D.H.

    1986-06-01

    The connection between the rotation matrix in hexagonal lattice coordinates and an angle-axis quadruple is given. The multiplication law of quadruples is derived. It corresponds to multiplying two matrices and gives the effect of two successive rotations. The relation is given between two quadruples that describe the same relative orientation of two lattices due to their hexagonal symmetry; a unique standard description of the relative orientation is proposed. The restrictions satisfied by rotations generating coincidence site lattices (CSLs) are derived for any value of the axial ratio rho = c/a. It is shown that the law for cubic lattices, where the multiplicity SIGMA of the CSL was equal to the least common denominator of the elements of the rotation matrix, does not always hold for hexagonal lattices. A generalisation of this law to lattices of arbitrary symmetry is given and another, quicker method to determine SIGMA for hexagonal lattices is derived. Finally, convenient algorithms are described for determining bases of the CSL and the DSC lattice. (author)

  9. Fast counting electronics for neutron coincidence counting

    International Nuclear Information System (INIS)

    Swansen, J.E.

    1987-01-01

    This patent describes a high speed circuit for accurate neutron coincidence counting comprising: neutron detecting means for providing an above-threshold signal upon neutron detection; amplifying means inputted by the neutron detecting means for providing a pulse output having a pulse width of about 0.5 microseconds upon the input of each above threshold signal; digital processing means inputted by the pulse output of the amplifying means for generating a pulse responsive to each input pulse from the amplifying means and having a pulse width of about 50 nanoseconds effective for processing an expected neutron event rate of about 1 Mpps: pulse stretching means inputted by the digital processing means for producing a pulse having a pulse width of several milliseconds for each pulse received form the digital processing means; visual indicating means inputted by the pulse stretching means for producing a visual output for each pulse received from the digital processing means; and derandomizing means effective to receive the 50 ns neutron event pulses from the digital processing means for storage at a rate up to the neutron event rate of 1 Mpps and having first counter means for storing the input neutron event pulses

  10. Complex action support from coincidences of couplings

    International Nuclear Information System (INIS)

    Nielsen, H.B.

    2011-01-01

    Our model (Refs. 1–7) with a complex action in a functional integral formulation with path integrals extending over all times, both past and future, is reviewed. Several numerical relations between coupling constants are presented as supporting evidence. The new evidence is that several more hitherto unexplained coincidences are explained by our model: (1) The "scale problem" is solved because the Higgs field expectation value is predicted to be very small compared to say some fundamental scale, that might be the Planck scale. (2) The Higgs VEV need not be just zero, but rather is predicted to be so that the running top-quark Yukawa coupling just is about to be unity at this scale; in this way the (weak) scale easily becomes "exponentially small." Instead of the top-Yukawa we should rather say the highest flavor Yukawa coupling here. These predictions are only achieved by allowing the principle of minimization of the imaginary part of the action SI(history) to a certain extent adjust some coupling constants in addition to the initial conditions. If supersymmetric partners are not found at LHC it would strengthen the need for a "solution" to the hierarchy problem in our direction of an explanation via a fine-tuning scheme inside the Standard Model, from say minimizing "the imaginary part of the action" in our complex action model. (author)

  11. Electron beam based transversal profile measurements of intense ion beams; Elektronenstrahl-Diagnostik zur Bestimmung vom transversalen Profil intensiver Ionenstrahlen

    Energy Technology Data Exchange (ETDEWEB)

    El Moussati, Said

    2014-11-03

    A non-invasive diagnostic method for the experimental determination of the transverse profile of an intense ion beam has been developed and investigated theoretically as well as experimentally within the framework of the present work. The method is based on the deflection of electrons when passing the electromagnetic field of an ion beam. To achieve this an electron beam is employed with a specifically prepared transversal profile. This distinguish this method from similar ones which use thin electron beams for scanning the electromagnetic field [Roy et al. 2005; Blockland10]. The diagnostic method presented in this work will be subsequently called ''Electron-Beam-Imaging'' (EBI). First of all the influence of the electromagnetic field of the ion beam on the electrons has been theoretically analyzed. It was found that the magnetic field causes only a shift of the electrons along the ion beam axis, while the electric field only causes a shift in a plane transverse to the ion beam. Moreover, in the non-relativistic case the magnetic force is significantly smaller than the Coulomb one and the electrons suffer due to the magnetic field just a shift and continue to move parallel to their initial trajectory. Under the influence of the electric field, the electrons move away from the ion beam axis, their resulting trajectory shows a specific angle compared to the original direction. This deflection angle practically depends just on the electric field of the ion beam. Thus the magnetic field has been neglected when analysing the experimental data. The theoretical model provides a relationship between the deflection angle of the electrons and the charge distribution in the cross section of the ion beam. The model however only can be applied for small deflection angles. This implies a relationship between the line-charge density of the ion beam and the initial kinetic energy of the electrons. Numerical investigations have been carried out to clarify the application range of the EBI diagnostic method and to benchmark the theoretical model. To achieve this goal a code has been developed in the programming language Python. Different charge distributions were considered and the simulation results have been compared with the theoretical model. The numerical investigations have shown a very good agreement with the theoretical model for deflection angles up to 20 mrad. This value defines the limit for the applicability of the theoretical model. Moreover, the magnetic field of the ion beam has also been taken into acount in the simulations. The results show that at high ion beam currents - starting at about 1 A - the electrons experience a non-negligible displacement along the ion beam axis, which has to be taken into consideration in experiments with intense heavy ion beams. The electrons suffer practically the same displacement under the influence of the magnetic field, regardless of their offset. At an offset of 10 mm the deviation from the shift at the ion beam axis is less than 3 %. For the experimental investigations of the EBI diagnostic method an offline experiment had been set up at the HHT experimental area at GSI in Darmstadt. The Coulomb field of the ion beam had been simulated by electrostatically charged wires. In case of a single wire, the experimental results are in good agreement with the theoretical model for deflection angles up to 20 mrad. This confirms the results of the numerical studies. To simulate the field within an ion beam, several wires have been clamped parallel to each other within a plane perpendicular to the electron beam. The electrons thus could pass through the spaces between the wires. The results of this experiments have quantitatively confirmed the prediction of the theoretical model that the derivative of the deflection angle with respect to the offset is proportional to the charge distribution in the cross section of the ion beam. Quantitatively, however, deviations from the theoretical model have been observed, which can be explained by the imprecise modelling of the charge distribution of an ion beam by the charged wires. The EBI diagnostic method has been applied for the first time in collaboration with the group of Professor Ulrich Ratzinger at the FRANZ accelerator at the Goethe University Frankfurt am Main for low-energy, DC ion beams - {sup 4}He{sup +} at 13.5 keV and a current of approximately 1 mA. The transverse charge distribution of these beams has been successfully determined by this diagnostic method. However the maximum deflection angle of the electrons was nearly 1/3 of the one predicted by the theoretical model. When employing an electron filter located along the ion beam line before the diagnostic chamber an increase of the deflection angle was observed. This suggests that electrons are generated by collisions of ions with background gas in such an amount, that they strongly influence the electrostatic field of the ion beam. This fact has to be more closely investigated in the future.

  12. Uranium mass and neutron multiplication factor estimates from time-correlation coincidence counts

    Energy Technology Data Exchange (ETDEWEB)

    Xie, Wenxiong [China Academy of Engineering Physics, Center for Strategic Studies, Beijing 100088 (China); Li, Jiansheng [China Academy of Engineering Physics, Institute of Nuclear Physics and Chemistry, Mianyang 621900 (China); Zhu, Jianyu [China Academy of Engineering Physics, Center for Strategic Studies, Beijing 100088 (China)

    2015-10-11

    Time-correlation coincidence counts of neutrons are an important means to measure attributes of nuclear material. The main deficiency in the analysis is that an attribute of an unknown component can only be assessed by comparing it with similar known components. There is a lack of a universal method of measurement suitable for the different attributes of the components. This paper presents a new method that uses universal relations to estimate the mass and neutron multiplication factor of any uranium component with known enrichment. Based on numerical simulations and analyses of 64 highly enriched uranium components with different thicknesses and average radii, the relations between mass, multiplication and coincidence spectral features have been obtained by linear regression analysis. To examine the validity of the method in estimating the mass of uranium components with different sizes, shapes, enrichment, and shielding, the features of time-correlation coincidence-count spectra for other objects with similar attributes are simulated. Most of the masses and multiplications for these objects could also be derived by the formulation. Experimental measurements of highly enriched uranium castings have also been used to verify the formulation. The results show that for a well-designed time-dependent coincidence-count measuring system of a uranium attribute, there are a set of relations dependent on the uranium enrichment by which the mass and multiplication of the measured uranium components of any shape and size can be estimated from the features of the source-detector coincidence-count spectrum.

  13. Measure of enzymatic activity coincident with 2450 MHz microwave exposure

    Energy Technology Data Exchange (ETDEWEB)

    Ward, T R; Allis, J W; Elder, J A

    1975-09-01

    Enzyme preparations were exposed to microwave radiation at 2450 MHz and enzymatic activity was simultaneously monitored spectrophotometrically with a crossed-beam exposure detection system. Enzymes studied were glucose 6-phosphate dehydrogenase from human red blood cells and yeast, adenylate kinase from rat liver mitochondria and rabbit muscle, and rat liver microsomal NADPH cytochrome c reductase. No difference was found between the specific activity at 25/sup 0/C of unirradiated controls and enzyme preparations irradiated at an absorbed dose rate of 42 W/kg.

  14. Anordnung fuer die optische Ueberwachung und/oder Bestimmung physikalischer und/oder chemischer Messgroessen

    OpenAIRE

    Wilhelmi, B.; Schreiber, J.; Nebel, D.

    2007-01-01

    WO 2009068023 A2 UPAB: 20090629 NOVELTY - The assembly giving an optical monitoring and/or measurement of physical and/or chemical has an optic fiber (1) to carry electromagnetic radiation to an optical detector. The fiber has a sensitive zone, where the fiber material is replaced by a material or mixture, which is optically transparent in the radiation wavelength. The replacement material has the same refractive index as the fiber or the refractive index deviation is less than difference bet...

  15. Coincident photoelectron spectroscopy on superconductors; Koinzidente Photoelektronenspektroskopie an Supraleitern

    Energy Technology Data Exchange (ETDEWEB)

    Voss, Stefan

    2011-07-01

    Aim of the performed experiments of this thesis was to attempt to detect Cooper pairs as carriers of the superconducting current directly by means of the photoelectric effect. The method of the coincident photoelectron spectroscopy aims thereby at the detection of two coherently emitted electrons by the interaction with a photon. Because electrostatic analyzers typically cover only a very small spatial angle, which goes along with very low coincidence rates, in connection with this thesis a time-of-flight projection system has been developed, which maps nearly the whole spatial angle on a position-resolving detector. The pulsed light source in form of special synchrotron radiation necessary for the measurement has been adjusted so weak, that only single photons could arrive at the sample. Spectroscoped were beside test measurements on silver layers both a lead monocrystal as representative of the classical BCS superconductors and monocrystalline Bi{sub 2}Sr{sub 2}CaCu{sub 2}O{sub 8} from the family of the high-temperature superconductors. With excitation energies up to 40 eV could be shown that sufficiently smooth and clean surfaces in the superconducting phase exhibit within the resolving power of about 0.5 eV no recognizable differences in comparison to the normally conducting phase. Beside these studies furthermore the simple photoemission at the different samples and especially in the case of the lead crystal is treated, because here no comparable results are known. Thereby the whole momentum space is discussed and the Fermi surface established as three-dimensional model, by means of which the measurement results are discussed. in the theoretical descriptions different models for the Cooper-pair production are presented, whereby to the momentum exchange with the crystal a special role is attributed, because this can only occur in direct excitations via discrete lattice vectors.

  16. Gamma--gamma directional correlations and coincidence studies in /sup 154/Gd

    Energy Technology Data Exchange (ETDEWEB)

    Gupta, J B; Gupta, S L; Hamilton, J H; Ramayya, A V [Vanderbilt Univ., Nashville, Tenn. (USA). Dept. of Physics; Delhi Univ. (India). Ramjas Coll.)

    1977-06-01

    The intensities, placements and E2/M1 mixing ratios of transitions in the decay of /sup 154/Eu have been carefully studied to provide accurate data for microscopic calculations. Coincidence relationships in thhe decay of /sup 154/Eu have been studied extensively with a multiparameter ..gamma..-..gamma.. coincidence system with two large volume Ge(Li) detectors. Spectra in coincidence with twenty energy gates were analyzed. Twenty-nine new coincidence relationships were established and confirmed most, but not all, of several levels previously assigned by energy fits only. From an analysis of coincidence spectra and singles spectra with a 18% efficiency Ge(Li) detector new information on the gamma-ray intensities were obtained. Precise values of the E2/M1 mixing ratios of transitions from the gamma- and beta-vibrational bands to the g.s. band have been determined from ..gamma..-..gamma.. directional correlation measurements with a NaI(Tl)-Ge(Li) detector coincidence system. Mixing ratios were obtained for a number of other transitions including those from KPI = 0/sup -/ and 2+ bands from direct and skipped cascade correlations.

  17. Gamma-gamma directional correlations and coincidence studies in 154Gd

    International Nuclear Information System (INIS)

    Gupta, J.B.; Gupta, S.L.; Hamilton, J.H.; Ramayya, A.V.; Delhi Univ.

    1977-01-01

    The intensities, placements and E2/M1 mixing ratios of transitions in the decay of 154 Eu have been carefully studied to provide accurate data for microscopic calculations. Coincidence relationships in thhe decay of 154 Eu have been studied extensively with a multiparameter γ-γ coincidence system with two large volume Ge(Li) detectors. Spectra in coincidence with twenty energy gates were analyzed. Twenty-nine new coincidence relationships were established and confirmed most, but not all, of several levels previously assigned by energy fits only. From an analysis of coincidence spectra and singles spectra with a 18% efficiency Ge(Li) detector new information on the gamma-ray intensities were obtained. Precise values of the E2/M1 mixing ratios of transitions from the gamma- and beta-vibrational bands to the g.s. band have been determined from γ-γ directional correlation measurements with a NaI(Tl)-Ge(Li) detector coincidence system. Mixing ratios were obtained for a number of other transitions including those from KPI = 0 - and 2+ bands from direct and skipped cascade correlations. (orig.) [de

  18. Operations manual for the megachannel gamma-ray coincidence system

    International Nuclear Information System (INIS)

    Ruhter, W.

    1977-01-01

    To aid in the study of nuclear structures, a megachannel pulse-height coincidence analysis system on a PDP-8 computer was constructed. The system digitizes the energies of coincident gamma-rays and stores the resultant information on a moving-head disk. The system uses a minicomputer to sort and store gamma-gamma coincident information on line. The megachannel system and how to use it are described

  19. Analysis of 125Xe electron-photon coincidence decay

    International Nuclear Information System (INIS)

    Klingberg, F.J.; Biegalski, S.R.

    2016-01-01

    As part of the verification component of the Comprehensive Nuclear-Test-Ban Treaty (CTBT), environmental gas samples originating from nuclear fission are analyzed for the presence of 131m Xe, 133m Xe, 133 Xe, and 135 Xe. In this work, the non-traditional radioxenon isotope 125 Xe was investigated. The isotope was produced as an isotopically pure sample via neutron activation of 124 Xe at the University of Texas at Austin Nuclear Engineering Teaching Lab's TRIGA MARK II Reactor. The sample was then measured using a HPGe detector as well as an ARSA-style b-c coincidence detector. Potential sources and sensitivities for production of 125 Xe are also considered for relevance to the CTBT verification mission. (author)

  20. Low level GAMMA0 spectrometry by beta-gamma coincidence

    International Nuclear Information System (INIS)

    Grigorescu, E.L.; Luca, A.; Razdolescu, A.C.; Ivan, C.

    1999-01-01

    Low level gamma spectrometry has a wide application, especially in environmental monitoring. Two variants, based on a beta-gamma coincidence technique, were studied. The equipment was composed of a beta detector and a Ge(Li) gamma detector (6% - relative efficiency), with the associated electronics. The gamma rays are recorded by the multichannel analyzer (4096 channels) only if the associated beta particles, which precede the gamma transitions, are registered in coincidence. Two types of beta detectors were used: plastic and liquid scintillators. In both cases, an external lead shield of 5 cm thick was used. The integral gamma background (50-1700 KeV) was reduced about 85 and 50 times, respectively. The corresponding MDA (Minimum Detectable Activity) values decreased about 1.5 and (3-7) times, respectively. The 2π sr plastic beta detector was placed on top the Ge(Li). The sample was inserted between the two detectors. The measurement time was 10 4 s. A 4π sr detector, built of the same material, was also studied, but it proved to be less advantageous because the background was reduced only 16 times; for a MDA reduction similar with that of the 2π sr variant, a longer measurement was needed (3.10 4 s). The other type of beta detector used, was a liquid scintillator. The dissolving of the samples in scintillator ensures a 4π sr measurement geometry. The vials with scintillator (10 ml volume) were placed on top the Ge(Li) and visualised by the photocathode of a phototube. This setup was surrounded by an enclosure which prevent the light penetration. The measurement time was 10 4 s. The only difficulty encountered in this low level measurement method is the accurate determination of the beta efficiency. A limitation is the possibility to measure only small mass samples. These variants are more simple and cheaper than others, previously studied. The advantage of the method is obvious when, instead of low MDA values, shorter measurement times are preferred. The

  1. A flexible VME-based multiparametric apparatus for coincidence spectroscopy and investigation of parameters of detectors

    International Nuclear Information System (INIS)

    Jakubek, J.

    2000-01-01

    The methodology of Coincidence Instrumental Activation Analysis (CIAA) based on a three-parameter gamma-gamma coincidence spectrometer with two high-purity Ge detectors is presented. A flexible coincidence system was built on standard NIM spectrometric modules connected to a VME or CAMAC data acquisition system. The detailed setup of the system optimized for the maximum energy resolution, maximum data throughput (dead time correction, pile-up rejection) and maximum flexibility is described. The use of different data acquisition platforms is discussed (VME bus with several different controllers, CAMAC bus). The software developed for reading and basic processing of measured data is also described. The possibilities of off-line data evaluation are discussed. The system was tested with respect to its compliance with the criteria of the CIAA method. Some results of measurement by this method are also presented. The flexibility of the system is demonstrated on its ability to measure the time characteristics of different detectors. (author)

  2. Coincidence Imaging and interference with coherent Gaussian beams

    Institute of Scientific and Technical Information of China (English)

    CAI Yang-jian; ZHU Shi-yao

    2006-01-01

    we present a theoretical study of coincidence imaging and interference with coherent Gaussian beams The equations for the coincidence image formation and interference fringes are derived,from which it is clear that the imaging is due to the corresponding focusing in the two paths .The quality and visibility of the images and fringes can be high simultaneously.The nature of the coincidence imaging and interference between quantum entangled photon pairs and coherent Gaussian beams are different .The coincidence image with coherent Gaussian beams is due to intensity-intensity correspondence,a classical nature,while that with entangled photon pairs is due to the amplitude correlation a quantum nature.

  3. A 15 channel 2- and 3-fold coincidence counting system for radioactivity standardization

    International Nuclear Information System (INIS)

    Simpson, B.R.S.; Meyer, B.R.; Raave, D.A.

    1986-01-01

    The 4π β-γ liquid scintillation coincidence counting system which is used at the National Accelerator Centre for standardizing radioisotopes, has been extended to allow for up to fifteen data points to be measured simultaneously by introducing a 15-fold coincidence unit and a 32-channel scaler into the system. A new control / data acquisition computer program has been written and its operation explained in detail. The advantages of the new system are discussed, and the activity of a 139 Ce source as measured by the new system and the old 3-fold system is compared

  4. Determination of plutonium in nuclear fuels using the neutron coincidence method

    International Nuclear Information System (INIS)

    Boehnel, K.

    1978-03-01

    In assays for plutonium the neutron coincidence technique is often used. This method which is based on measuring spontaneous fission rates is examined both experimentally and theoretically. A novel coincidence unit is described which works in effect without deadtime and which therefore has advantages over the currently used design. For waste samples a principle for measurement is described which avoids space dependence effects by rotating the probe in an asymmetric detector. Formulae are developed for the statistical error and various effects of deadtimes are discussed. Further it is shown that neutron multiplication in the sample is an important source of errors, especially when the (α, n)-background is neglected. (author)

  5. Intrinsic coincident full-Stokes polarimeter using stacked organic photovoltaics.

    Science.gov (United States)

    Yang, Ruonan; Sen, Pratik; O'Connor, B T; Kudenov, M W

    2017-02-20

    An intrinsic coincident full-Stokes polarimeter is demonstrated by using strain-aligned polymer-based organic photovoltaics (OPVs) that can preferentially absorb certain polarized states of incident light. The photovoltaic-based polarimeter is capable of measuring four Stokes parameters by cascading four semitransparent OPVs in series along the same optical axis. This in-line polarimeter concept potentially ensures high temporal and spatial resolution with higher radiometric efficiency as compared to the existing polarimeter architecture. Two wave plates were incorporated into the system to modulate the S3 Stokes parameter so as to reduce the condition number of the measurement matrix and maximize the measured signal-to-noise ratio. Radiometric calibration was carried out to determine the measurement matrix. The polarimeter presented in this paper demonstrated an average RMS error of 0.84% for reconstructed Stokes vectors after normalized to S0. A theoretical analysis of the minimum condition number of the four-cell OPV design showed that for individually optimized OPV cells, a condition number of 2.4 is possible.

  6. Application of GESPECOR software for the calculation of coincidence summing effects in special cases

    International Nuclear Information System (INIS)

    Arnold, Dirk; Sima, Octavian

    2004-01-01

    In this work, coincidence summing correction factors have been measured for 133 Ba, 152 Eu and 88 Y point sources with a 50% relative efficiency p-type detector and a 25% relative efficiency n-type detector in two close-to-detector measurement geometries. The experimental data for 133 Ba and 152 Eu and the results obtained with the GESPECOR software reveal a complex structure of the conventional dead layer of the p-type detector. The high value of the coincidence summing correction factor for the 511 keV peak of 88 Y, in agreement with the values computed by GESPECOR, in this case cautions against the application of the semiempirical method for evaluating coincidence summing effects

  7. A magnetic-lens - mini-orange coincidence spectrometer

    International Nuclear Information System (INIS)

    Bargholtz, C.; Holmberg, L.; Ruus, N.; Tegner, P.E.; Weiss, G.

    1997-04-01

    A coincidence spectrometer consisting of a Gerholm type magnetic lens and a permanent magnet mini-orange spectrometer is described. Electron-electron or electron-positron coincidences may be registered in various angular settings. The spectrometer has been developed mainly to search for anomalous contributions to Bhabha scattering or positrons and is at present used for such studies. 6 refs

  8. An Inexpensive Coincidence Circuit for the Pasco Geiger Sensors

    CERN Document Server

    Fichera, F; Librizzi, F; Riggi, F

    2005-01-01

    A simple coincidence circuit was devised to carry out educational coincidence experiments involving the use of Geiger counters. The system was tested by commercially available Geiger sensors from PASCO, and is intended to be used in collaboration with high school students and teachers

  9. Study on the eγ coincidences in the 169Lu decay

    International Nuclear Information System (INIS)

    Batsev, S.; Bonch-Osmolovskaya, N.A.; Budzyak, A.; Kuznetsov, V.V.; Usmanov, R.R.

    1979-01-01

    The 169 Lu→ 169 Yb decay scheme was analyzed on the basis of measurements of eγ coincidence. The 169 Lu sources were obtained by irradiating a tantalum target by 660 MeV protons. The eγ-coincidence spectra were measured by an ironless β-spectrometer with a toroidal magnetic field and a detector. The γ-ray and eγ-coincidence spectra were processed by a computer. The results of processing the 169 Lu coincidence spectra are tabulated. No excited states of 169 Yb not confirmed by γγ and eγ coincidences (except for the head level of the 3/2 + (651) 720 keV band) remain in the 169 Lu decay scheme proposed. Weak transitions with the total intensity of no more than 3.3% per a 169 Lu decay have remained unarranged, they should discharge weakly excited levels of 169 Yb. Probabilities of the 169 Yb level population per a 169 Lu decay and the corresponding values of probabilities of transitions in them are presented. As a whole, the 169 Lu decay scheme involves 60 levels, 31 states of them are new

  10. Recovery and normalization of triple coincidences in PET

    Energy Technology Data Exchange (ETDEWEB)

    Lage, Eduardo, E-mail: elage@mit.edu; Parot, Vicente; Dave, Shivang R.; Herraiz, Joaquin L. [Madrid-MIT M+Visión Consortium, Massachusetts Institute of Technology, Cambridge, Massachusetts 02139 (United States); Moore, Stephen C.; Sitek, Arkadiusz; Park, Mi-Ae [Division of Nuclear Medicine, Department of Radiology, Harvard Medical School and Brigham and Women’s Hospital, Boston, Massachusetts 02115 (United States); Udías, Jose M. [Grupo de Física Nuclear, Departamento de Física Atómica Molecular y Nuclear, Universidad Complutense de Madrid, CEI Moncloa, Madrid 28040 (Spain); Vaquero, Juan J. [Departamento de Ingeniería Biomédica e Ingeniería Aeroespacial, Universidad Carlos III de Madrid, Leganés 28911 (Spain)

    2015-03-15

    Purpose: Triple coincidences in positron emission tomography (PET) are events in which three γ-rays are detected simultaneously. These events, though potentially useful for enhancing the sensitivity of PET scanners, are discarded or processed without special consideration in current systems, because there is not a clear criterion for assigning them to a unique line-of-response (LOR). Methods proposed for recovering such events usually rely on the use of highly specialized detection systems, hampering general adoption, and/or are based on Compton-scatter kinematics and, consequently, are limited in accuracy by the energy resolution of standard PET detectors. In this work, the authors propose a simple and general solution for recovering triple coincidences, which does not require specialized detectors or additional energy resolution requirements. Methods: To recover triple coincidences, the authors’ method distributes such events among their possible LORs using the relative proportions of double coincidences in these LORs. The authors show analytically that this assignment scheme represents the maximum-likelihood solution for the triple-coincidence distribution problem. The PET component of a preclinical PET/CT scanner was adapted to enable the acquisition and processing of triple coincidences. Since the efficiencies for detecting double and triple events were found to be different throughout the scanner field-of-view, a normalization procedure specific for triple coincidences was also developed. The effect of including triple coincidences using their method was compared against the cases of equally weighting the triples among their possible LORs and discarding all the triple events. The authors used as figures of merit for this comparison sensitivity, noise-equivalent count (NEC) rates and image quality calculated as described in the NEMA NU-4 protocol for the assessment of preclinical PET scanners. Results: The addition of triple-coincidence events with the

  11. Recovery and normalization of triple coincidences in PET.

    Science.gov (United States)

    Lage, Eduardo; Parot, Vicente; Moore, Stephen C; Sitek, Arkadiusz; Udías, Jose M; Dave, Shivang R; Park, Mi-Ae; Vaquero, Juan J; Herraiz, Joaquin L

    2015-03-01

    Triple coincidences in positron emission tomography (PET) are events in which three γ-rays are detected simultaneously. These events, though potentially useful for enhancing the sensitivity of PET scanners, are discarded or processed without special consideration in current systems, because there is not a clear criterion for assigning them to a unique line-of-response (LOR). Methods proposed for recovering such events usually rely on the use of highly specialized detection systems, hampering general adoption, and/or are based on Compton-scatter kinematics and, consequently, are limited in accuracy by the energy resolution of standard PET detectors. In this work, the authors propose a simple and general solution for recovering triple coincidences, which does not require specialized detectors or additional energy resolution requirements. To recover triple coincidences, the authors' method distributes such events among their possible LORs using the relative proportions of double coincidences in these LORs. The authors show analytically that this assignment scheme represents the maximum-likelihood solution for the triple-coincidence distribution problem. The PET component of a preclinical PET/CT scanner was adapted to enable the acquisition and processing of triple coincidences. Since the efficiencies for detecting double and triple events were found to be different throughout the scanner field-of-view, a normalization procedure specific for triple coincidences was also developed. The effect of including triple coincidences using their method was compared against the cases of equally weighting the triples among their possible LORs and discarding all the triple events. The authors used as figures of merit for this comparison sensitivity, noise-equivalent count (NEC) rates and image quality calculated as described in the NEMA NU-4 protocol for the assessment of preclinical PET scanners. The addition of triple-coincidence events with the authors' method increased peak

  12. High rate 4π β-γ coincidence counting system

    International Nuclear Information System (INIS)

    Johnson, L.O.; Gehrke, R.J.

    1978-01-01

    A high count rate 4π β-γ coincidence counting system for the determination of absolute disintegration rates of short half-life radionuclides is described. With this system the dead time per pulse is minimized by not stretching any pulses beyond the width necessary to satisfy overlap coincidence requirements. The equations used to correct for the β, γ, and coincidence channel dead times and for accidental coincidences are presented but not rigorously developed. Experimental results are presented for a decaying source of 56 Mn initially at 2 x 10 6 d/s and a set of 60 Co sources of accurately known source strengths varying from 10 3 to 2 x 10 6 d/s. A check of the accidental coincidence equation for the case of two independent sources with varying source strengths is presented

  13. Ion conductivity and mass spectrometry of methanol diffusion and electroosmotic drag on proton-conducting membranes for the Direct Methanol Fuel Cell (DMFC); Ionische Leitfaehigkeit und massenspektrometrische Bestimmung der Methanol-Diffusion und des 'Electroosmotic Drag' an protonenleitenden Membranen fuer die Direkt-Methanol-Brennstoffzelle (DMFC)

    Energy Technology Data Exchange (ETDEWEB)

    Oeztuerk, N.

    2001-07-01

    The methanol permeability of the nafion membrane is one reason why the DMFC is not marketable as yet. As a result of diffusion, permeation and electroosmotic drag, methanol is transferred to the kation side where it will reduce the fuel cell performance. Research is going on world-wide to develop new materials that will prevent methanol crossover. The report describes the development of a measuring cell that will provide the necessary information on diffusion, permeation, electroosmotic drag and conductivity. [German] Ein wesentlicher Grund, der die Einfuehrung der DMFC noch verhindert, ist die Methanoldurchlaessigkeit der Nafion-Membran. Durch Diffusion und Permeation und durch den Electroosmotic Drag gelangt Methanol auf die Kathodenseite und fuehrt dann zu einem Leistungsabfall der Brennstoffzelle. Daher werden weltweit neue Materialien entwickelt, die bei guter lonenleitfaehigkeit den Methanol-crossover unterdruecken. Zur Beurteilung und Weiterentwicklung der neuen Materialien werden Informationen zur Diffusion, Permeation, zum Electroosmotic Drag und zur Leitfaehigkeit benoetigt. Um diese Parameter schnell und einfach zu bestimmen, wurde im Rahmen der vorliegenden Arbeit eine Messzelle weiter entwickelt. Diese Messzelle erlaubt die schnelle Bestimmung aller vier wichtigen Parameter. (orig.)

  14. Passive neutron coincidence counting with plastic scintillators for the characterization of radioactive waste drums

    Energy Technology Data Exchange (ETDEWEB)

    Deyglun, C.; Simony, B.; Perot, B.; Carasco, C. [CEA, DEN, Cadarache, Nuclear Measurement Laboratory, F-13108 Saint-Paul-lez-Durance (France); Saurel, N.; Colas, S. [CEA, DAM, Valduc, F-21120 Is-sur-Tille (France); Collot, J. [Laboratoire de Physique Subatomique et de Cosmologie, Universite Grenoble Alpes, CNRS/IN2P3, Grenoble (France)

    2015-07-01

    The quantification of radioactive material is essential in the fields of safeguards, criticality control of nuclear processes, dismantling of nuclear facilities and components, or radioactive waste characterization. The Nuclear Measurement Laboratory (LMN) of CEA is involved in the development of time-correlated neutron detection techniques using plastic scintillators. Usually, 3He proportional counters are used for passive neutron coincidence counting owing to their high thermal neutron capture efficiency and gamma insensitivity. However, the global {sup 3}He shortage in the past few years has made these detectors extremely expensive. In addition, contrary to {sup 3}He counters for which a few tens of microseconds are needed to thermalize fast neutrons, in view to maximize the {sup 3}He(n,p){sup 3}H capture cross section, plastic scintillators are based on elastic scattering and therefore the light signal is formed within a few nanoseconds, correlated pulses being detected within a few dozen- or hundred nanoseconds. This time span reflects fission particles time of flight, which allows reducing accordingly the duration of the coincidence gate and thus the rate of random coincidences, which may totally blind fission coincidences when using {sup 3}He counters in case of a high (α,n) reaction rate. However, plastic scintillators are very sensitive to gamma rays, requiring the use of a thick metallic shield to reduce the corresponding background. Cross talk between detectors is also a major issue, which consists on the detection of one particle by several detectors due to elastic or inelastic scattering, leading to true but undesired coincidences. Data analysis algorithms are tested to minimize cross-talk in simultaneously activated detectors. The distinction between useful fission coincidences and the correlated background due to cross-talk, (α,n) and induced (n,2n) or (n,n'γ) reactions, is achieved by measuring 3-fold coincidences. The performances of a

  15. Sustaining IAEA Neutron Coincidence Counting: Past, Present and Future

    International Nuclear Information System (INIS)

    Longo, J.; Schaffer, K.M.; Nordquist, H.

    2015-01-01

    Los Alamos National Laboratory's IAEA Neutron Coincidence Counting (INCC) code is the standard tool for neutron coincidence counting measurements. INCC software and its' predecessors were originally implemented in the 1970s. The measurement and analysis techniques perfected in the code arise from many years of laboratory and field experience by nuclear engineers and physicists. Covering the full arc of INCC's lifecycle, we discuss the engineering approaches used for conception, original development, worldwide deployment of the stand-alone Windows application, more than a decade of sustained maintenance support, and our recent work to carry INCC successfully into future applications. We delve into the recent re-architecture of the INCC code base, an effort to create a maintainable and extensible architecture designed to preserve the existing INCC code base while adding support for new analyzes and instruments (e.g., List Mode PTR-32 and the List Mode Multiplicity Module). INCC now consists of separate modules implementing attended instrumentation control, data file processing, statistical and Pu mass calculation and analyzes, list mode counting and analyzes, reporting functions, and a database support library. Separating functional capabilities in this architecture enables better testing, isolates development risk and enables the use of INCC features in other software systems. We discuss our approach to handling divergent data and protocol support as a result of this re-architecture. INCC has complex testing requirements; we show how the testing effort was reduced by breaking the software into separate modules. This new architecture enables integration of INCC analysis into the IAEA's new Integrated Review and Analysis Programme (iRAP) data review system. iRAP is based on the respected Euratom Comprehensive Review Inspector Software Package (CRISP) software framework, and is expected to be the future data review system for IAEA and Euratom

  16. Moisture corrections in neutron coincidence counting of PuO2

    International Nuclear Information System (INIS)

    Stewart, J.E.; Menlove, H.O.

    1987-01-01

    Passive neutron coincidence counting is capable of 1% assay accuracy for pure, well-characterized PuO 2 samples that contain plutonium masses from a few tens of grams to several kilograms. Moisture in the sample can significantly bias the assay high by changing the (α,n) neutron production, the sample multiplication, and the detection efficiency. Monte Carlo calculations and an analytical model of coincidence counting have been used to quantify the individual and cumulative effects of moisture biases for two PuO 2 sample sizes and a range of moisture levels from 0 to 9 wt %. Results of the calculations suggest a simple correction procedure for moisture bias that is effective from 0 to 3 wt % H 2 O. The procedure requires that the moisture level in the sample be known before the coincidence measurement

  17. Secondary electron/reflected particle coincidence studies during slow highly charged ion-surface interactions

    Energy Technology Data Exchange (ETDEWEB)

    McGrath, C.T.; Szilagyi, Z.; Shah, M.B.; McCullough, R.W. [Queen' s Univ., Belfast, Northern Ireland (United Kingdom); Woolsey, J.M. [Stirling Univ. (United Kingdom). DBMS; Trassl, R.; Salzborn, E. [Giessen Univ. (Germany). Inst. fuer Kernphysik

    2001-07-01

    We have measured the secondary electron emission statistics (ES) for 5 keV N{sup q+} (q = 1-4) ions incident at 10 on polycrystalline aluminium, in coincidence with specularly reflected N{sup 0}. In this arrangement the kinetic contribution to secondary electron emission is minimised. The experimental data shows that the coincident electron yield, {gamma}, increases linearly with incident ion charge state. The kinetic emission contribution has also been determined from this data. The ES due to 2 and 4 keV He{sup 2+} impact on polycrystalline aluminium in coincidence with specularly reflected He{sup +} and He{sup 0} have also been determined. The process He{sup 2+} {yields} He{sup 0} yields a larger {gamma} value than the process He{sup 2+} {yields} He{sup +}. (orig.)

  18. Simulations of Lithium-Based Neutron Coincidence Counter for Gd-Loaded Fuel

    Energy Technology Data Exchange (ETDEWEB)

    Cowles, Christian C. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Kouzes, Richard T. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Siciliano, Edward R. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2014-10-01

    The Department of Energy Office of Nuclear Safeguards and Security (NA-241) is supporting the project Lithium-Based Alternative Neutron Detection Technology Coincidence Counting for Gd-loaded Fuels at Pacific Northwest National Laboratory for the development of a lithium-based neutron coincidence counter for nondestructively assaying Gd loaded nuclear fuel. This report provides results from MCNP simulations of a lithium-based coincidence counter for the possible measurement of Gd-loaded nuclear fuel. A comparison of lithium-based simulations and UNCL-II simulations with and without Gd loaded fuel is provided. A lithium-based model, referred to as PLNS3A-R1, showed strong promise for assaying Gd loaded fuel.

  19. Automatic analysis algorithm for radionuclide pulse-height data from beta-gamma coincidence systems

    International Nuclear Information System (INIS)

    Foltz Biegalski, K.M.

    2001-01-01

    There are two acceptable noble gas monitoring measurement modes for Comprehensive Nuclear-Test-Ban-Treaty (CTBT) verification purposes defined in CTBT/PC/II/WG.B/1. These include beta-gamma coincidence and high-resolution gamma-spectrometry. There are at present no commercial, off-the-shelf (COTS) applications for the analysis of β-γ coincidence data. Development of such software is in progress at the Prototype International Data Centre (PIDC) for eventual deployment at the International Data Centre (IDC). Flowcharts detailing the automatic analysis algorithm for β-γ coincidence data to be coded at the PIDC is included. The program is being written in C with Oracle databasing capabilities. (author)

  20. Calculations of coincident ionization plus excitation

    International Nuclear Information System (INIS)

    Becker, R.L.

    1986-01-01

    For Li- and Be-like ions, K x-ray yields, together with detection that the ionic charge has increased, give the cross section for ionization plus excitation (IE), a process which can exhibit electron-electron correlations. Measurements of IE for 14 Si 11+ + He stimulated our coupled-channels calculations in the independent-Fermi-particle model (IFPM), which includes Pauli correlations. We discuss how the IFPM expressions, generalized here to include an open shell, differ from those for distinguishable electrons. The sensitivity of σ/sub IE/ to correlations is shown. Recent additional measurements and future ones giving excitation functions for resolved configurations and complementary Auger data will provide even more sensitive tests of collisional correlation theory. 15 refs., 3 figs., 1 tab

  1. Introduction to Neutron Coincidence Counter Design Based on Boron-10

    Energy Technology Data Exchange (ETDEWEB)

    Kouzes, Richard T.; Ely, James H.; Lintereur, Azaree T.; Siciliano, Edward R.

    2012-01-22

    The Department of Energy Office of Nonproliferation Policy (NA-241) is supporting the project 'Coincidence Counting With Boron-Based Alternative Neutron Detection Technology' at Pacific Northwest National Laboratory (PNNL) for development of an alternative neutron coincidence counter. The goal of this project is ultimately to design, build and demonstrate a boron-lined proportional tube based alternative system in the configuration of a coincidence counter. This report, providing background information for this project, is the deliverable under Task 1 of the project.

  2. Some target assay uncertainties for passive neutron coincidence counting

    International Nuclear Information System (INIS)

    Ensslin, N.; Langner, D.G.; Menlove, H.O.; Miller, M.C.; Russo, P.A.

    1990-01-01

    This paper provides some target assay uncertainties for passive neutron coincidence counting of plutonium metal, oxide, mixed oxide, and scrap and waste. The target values are based in part on past user experience and in part on the estimated results from new coincidence counting techniques that are under development. The paper summarizes assay error sources and the new coincidence techniques, and recommends the technique that is likely to yield the lowest assay uncertainty for a given material type. These target assay uncertainties are intended to be useful for NDA instrument selection and assay variance propagation studies for both new and existing facilities. 14 refs., 3 tabs

  3. Low-resource synchronous coincidence processor for positron emission tomography

    International Nuclear Information System (INIS)

    Sportelli, Giancarlo; Belcari, Nicola; Guerra, Pedro; Santos, Andres

    2011-01-01

    We developed a new FPGA-based method for coincidence detection in positron emission tomography. The method requires low device resources and no specific peripherals in order to resolve coincident digital pulses within a time window of a few nanoseconds. This method has been validated with a low-end Xilinx Spartan-3E and provided coincidence resolutions lower than 6 ns. This resolution depends directly on the signal propagation properties of the target device and the maximum available clock frequency, therefore it is expected to improve considerably on higher-end FPGAs.

  4. Electron coincidence spectroscopy of sodium and potassium

    International Nuclear Information System (INIS)

    Frost, L.; Weigold, E.

    1982-03-01

    The Na 3s and K 4s electron momentum distributions have been obtained using the noncoplanar symmetric (e,2e) reaction at total energies of 800 eV and 1200 eV. They show excellent agreement with the results of plane wave impulse approximation calculations using Roothaan-Hartree-Fock functions, after small corrections are made for the finite angular resolution of the apparatus. The potassium valence s momentum profile is a little narrower than that for sodium, implying a correspondingly slightly larger spatial distribution of the outer valence electrons. The ratio between the (n-1)p and ns cross-sections at their respective maxima in q-space were measured to be 0.009 +- 0.003 and 0.019 +- 0.003 for Na and K respectively. These cross-section ratios are in agreement with the PWIA calculations

  5. Permutational symmetries for coincidence rates in multimode multiphotonic interferometry

    Science.gov (United States)

    Khalid, Abdullah; Spivak, Dylan; Sanders, Barry C.; de Guise, Hubert

    2018-06-01

    We obtain coincidence rates for passive optical interferometry by exploiting the permutational symmetries of partially distinguishable input photons, and our approach elucidates qualitative features of multiphoton coincidence landscapes. We treat the interferometer input as a product state of any number of photons in each input mode with photons distinguished by their arrival time. Detectors at the output of the interferometer count photons from each output mode over a long integration time. We generalize and prove the claim of Tillmann et al. [Phys. Rev. X 5, 041015 (2015), 10.1103/PhysRevX.5.041015] that coincidence rates can be elegantly expressed in terms of immanants. Immanants are functions of matrices that exhibit permutational symmetries and the immanants appearing in our coincidence-rate expressions share permutational symmetries with the input state. Our results are obtained by employing representation theory of the symmetric group to analyze systems of an arbitrary number of photons in arbitrarily sized interferometers.

  6. Use of sum-peak and coincidence counting methods for activity standardization of {sup 22}Na

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira, E.M. de, E-mail: estela@ird.gov.br [Laboratorio Nacional de Metrologia das Radiacoes Ionizantes (LNMRI/IRD/CNEN), Av. Salvador Allende, s/n, Recreio, CEP 22780-160 Rio de Janeiro (Brazil); Iwahara, A.; Poledna, R. [Laboratorio Nacional de Metrologia das Radiacoes Ionizantes (LNMRI/IRD/CNEN), Av. Salvador Allende, s/n, Recreio, CEP 22780-160 Rio de Janeiro (Brazil); Silva, M.A.L. da [Coordenacao Geral de Instalacoes Nucleares/Comissao Nacional de Energia Nuclear, R. Gal. Severiano, 90 - Botafogo, CEP 22290-901 Rio de Janeiro (Brazil); Tauhata, L. [Fundacao Carlos Chagas Filho de Amparo a Pesquisa do Estado do Rio de Janeiro (FAPERJ), Av. Erasmo Braga, 118-6 Degree-Sign andar, CEP 20020-000 Centro, Rio de Janeiro (Brazil); Delgado, J.U. [Laboratorio Nacional de Metrologia das Radiacoes Ionizantes (LNMRI/IRD/CNEN), Av. Salvador Allende, s/n, Recreio, CEP 22780-160 Rio de Janeiro (Brazil); Lopes, R.T. [Laboratorio de Instrumentacao Nuclear (LIN/PEN/COPPE/UFRJ), Caixa Postal 68509, CEP 21945-970 Rio de Janeiro (Brazil)

    2012-09-21

    A solution containing the positron emitter {sup 22}Na has been absolutely standardized using the 4{pi}{beta}-{gamma} coincidence counting method and the sum-peak spectrometry counting method. In the 4{pi}{beta}-{gamma} coincidence method two ways for the activity concentration measurements were used: gating on the 1275 keV photopeak and on the 1786 keV sum-peak where the knowledge of the {beta}{sup +}-branching ratio is required. In the sum-peak method the measurements were carried out using three experimental arrangements: the first composed by a well type 5 in. Multiplication-Sign 5 in. NaI(Tl) scintillation crystal, the second by a 3 in. Multiplication-Sign 3 in. NaI(Tl) scintillation crystal placed on the top of the first, resulting in a 4{pi} counting geometry and the third arrangement is a high purity coaxial germanium detector. The results that are obtained by these two methods are compatible within the standard uncertainty values with a coverage factor of k=2 ({approx}95% of the confidence level). This means that the sum-peak counting with its more simple experimental setup than the complex coincidence 4{pi}{beta}-{gamma} counting system gives consistent results for the activity standardization of {sup 22}Na with smaller uncertainties. Besides, the time period involved to attain the result of the standardization was quite shorter than the coincidence measurements used in this work.

  7. Calculation of the n-th coincidences frequency

    International Nuclear Information System (INIS)

    Mercier, C.

    1959-01-01

    Events can occur randomly with a given frequency. Each event lasts a Θ-time. During this Θ-time other events can occur. A coincidence beginning of order n at a t-time is when an event occurs while n other events already occurred between t-Θ and t. In this work the frequency of coincidence beginnings with an order greater than or equal to n is established

  8. Dynamic imaging with coincidence gamma camera

    International Nuclear Information System (INIS)

    Elhmassi, Ahmed

    2008-01-01

    In this paper we develop a technique to calculate dynamic parameters from data acquired using gamma-camera PET (gc PET). Our method is based on an algorithm development for dynamic SPECT, which processes all decency projection data simultaneously instead of reconstructing a series of static images individually. The algorithm was modified to account for the extra data that is obtained with gc PET (compared with SPEC). The method was tested using simulated projection data for both a SPECT and a gc PET geometry. These studies showed the ability of the code to reconstruct simulated data with a varying range of half-lives. The accuracy of the algorithm was measured in terms of the reconstructed half-life and initial activity for the simulated object. The reconstruction of gc PET data showed improvement in half-life and activity compared to SPECT data of 23% and 20%, respectively (at 50 iterations). The gc PET algorithm was also tested using data from an experimental phantom and finally, applied to a clinical dataset, where the algorithm was further modified to deal with the situation where the activity in certain pixels decreases and then increases during the acquisition. (author)

  9. Secondary electron emission studied by secondary electron energy loss coincidence spectroscopy (SE2ELCS)

    International Nuclear Information System (INIS)

    Khalid, R.

    2013-01-01

    Emission of secondary electrons is of importance in many branches of fundamental and applied science. It is widely applied in the electron microscope for the investigation of the structure and electronic state of solid surfaces and particle detection in electron multiplier devices, and generally it is related to the energy dissipation of energetic particles moving inside a solid. The process of secondary electron emission is a complex physical phenomenon, difficult to measure experimentally and treat theoretically with satisfactory accuracy. The secondary electron spectrum measured with single electron spectroscopy does not provide detailed information of the energy loss processes responsible for the emission of secondary electrons. This information can be accessed when two correlated electron pairs are measured in coincidence and the pair consists of a backscattered electron after a given energy loss and a resulting emitted secondary electron. To investigate the mechanisms responsible for the emission of secondary electrons, a reflection (e,2e) coincidence spectrometer named Secondary Electron Electron Energy Loss Coincidence Spectrometer (SE2ELCS) has been developed in the framework of this thesis which allows one to uncover the relation between the features in the spectra which are due to energy losses and true secondary electron emission structures. The correlated electron pairs are measured with a hemispherical mirror analyzer (HMA) and a time of flight analyzer (TOF) by employing a continuous electron beam. An effort has been made to increase the coincidence count rate by increasing the effective solid angle of the TOF analyzer and optimizing the experimental parameters to get optimum energy resolution. Double differential coincidence spectra for a number of materials namely, nearly free electron metals (Al, Si), noble metals (Ag, Au, Cu, W) and highly oriented pyrolytic graphite (HOPG) have been measured using this coincidence spectrometer. The

  10. Convergent input from brainstem coincidence detectors onto delay-sensitive neurons in the inferior colliculus.

    Science.gov (United States)

    McAlpine, D; Jiang, D; Shackleton, T M; Palmer, A R

    1998-08-01

    Responses of low-frequency neurons in the inferior colliculus (IC) of anesthetized guinea pigs were studied with binaural beats to assess their mean best interaural phase (BP) to a range of stimulating frequencies. Phase plots (stimulating frequency vs BP) were produced, from which measures of characteristic delay (CD) and characteristic phase (CP) for each neuron were obtained. The CD provides an estimate of the difference in travel time from each ear to coincidence-detector neurons in the brainstem. The CP indicates the mechanism underpinning the coincidence detector responses. A linear phase plot indicates a single, constant delay between the coincidence-detector inputs from the two ears. In more than half (54 of 90) of the neurons, the phase plot was not linear. We hypothesized that neurons with nonlinear phase plots received convergent input from brainstem coincidence detectors with different CDs. Presentation of a second tone with a fixed, unfavorable delay suppressed the response of one input, linearizing the phase plot and revealing other inputs to be relatively simple coincidence detectors. For some neurons with highly complex phase plots, the suppressor tone altered BP values, but did not resolve the nature of the inputs. For neurons with linear phase plots, the suppressor tone either completely abolished their responses or reduced their discharge rate with no change in BP. By selectively suppressing inputs with a second tone, we are able to reveal the nature of underlying binaural inputs to IC neurons, confirming the hypothesis that the complex phase plots of many IC neurons are a result of convergence from simple brainstem coincidence detectors.

  11. Primary standardization of {sup 152}Eu by 4πβ(LS) - γ (NaI) coincidence counting and CIEMAT-NIST method

    Energy Technology Data Exchange (ETDEWEB)

    Ruzzarin, A., E-mail: aruzzarin@nuclear.ufrj.br [Coordenacao de Pos-Graduacao e Pesquisa de Engenharia (LIN/PEN/COPPE/UFRJ), Rio de Janeiro, RJ (Brazil). Lab. de Instrumentação Nuclear; Cruz, P.A.L. da; Ferreira Filho, A.L.; Iwahara, A. [Instituto de Radioproteção e Dosimetria (LNMRI/IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil). Lab. Nacional de Metrologia das Radiações Ionizantes

    2017-07-01

    The 4πβ-γ coincidence counting and CIEMAT/NIST liquid scintillation method were used in the standardization of a solution of {sup 152}Eu. In CIEMAT/NIST method, measurements were performed in a Liquid Scintillation Counter model Wallac 1414. In the 4πβ-γ coincidence counting, the solution was standardized using a coincidence method with 'beta-efficiency extrapolation'. A simple 4πβ-γ coincidence system was used, with acrylic scintillation cell coupled to two coincident photomultipliers at 180° each other and NaI(Tl) detector. The activity concentrations obtained were 156.934 ± 0.722 and 157.403 ± 0.113 kBq/g, respectively, for CIEMAT/NIST and 4πβ-γ coincidence counting measurement methods. (author)

  12. Calibration and adjustment of the EGRET coincidence/time-of-flight system

    International Nuclear Information System (INIS)

    Hunter, S.D.

    1991-01-01

    The coincidence/time-of-flight system of the energetic gamma ray experiment telescope (EGRET) on NASA's Gamma Ray Observatory (GRO) consists of two layers of sixteen scintillator tiles. These tiles are paired into 96 coincidence telescopes. Valid coincidence and time-of-flight values (indicating downward moving particles) from one of these telescopes are two of the requirements for an EGRET event trigger. To maximize up-down discrimination, variations in the mean timing value of the telescopes must be minimized. The timing values of the 96 telescopes are not independent, hence they cannot be individually adjusted to calibrate the system. An iterative approach was devised to determine adjustments to the length of the photomultiplier signal cables. These adjustments were made directly in units of time using a time domain reflectometry technique, by timing the reflection of a fast pulse from the unterminated end of eable, and observing the charge in signal propagation time as the length of the cable was shortened. Two constant fraction discriminators, a time-to-amplitude converter and a pulse height analyzer were used for these measurements. Using this direct time measuring approach, the timing values for the 96 EGRET coincidence/time-of-flight telescopes were adjusted with an FWHM variation of less than 450 ps (± 1 TOF timing channel). (orig.)

  13. Standardization of iodine-129 by the TDCR liquid scintillation method and 4π β-γ coincidence counting

    Science.gov (United States)

    Cassette, P.; Bouchard, J.; Chauvenet, B.

    1994-01-01

    Iodine-129 is a long-lived fission product, with physical and chemical properties that make it a good candidate for evaluating the environmental impact of the nuclear energy fuel cycle. To avoid solid source preparation problems, liquid scintillation has been used to standardize this nuclide for a EUROMET intercomparison. Two methods were used to measure the iodine-129 activity: triple-to-double-coincidence ratio liquid scintillation counting and 4π β-γ coincidence counting; the results are in good agreement.

  14. The optimum choice of gate width for neutron coincidence counting

    Energy Technology Data Exchange (ETDEWEB)

    Croft, S., E-mail: crofts@ornl.gov [Safeguards and Security Technology (SST), Global Nuclear Security Technology Divisions, PO Box 2008, Building 5700, MS-6166, Oak Ridge, TN 37831-6166 (United States); Henzlova, D.; Favalli, A.; Hauck, D.K.; Santi, P.A. [Safeguards Science and Technology Group (NEN-1), Nuclear Engineering and Nonproliferation Division, MS-E540, Los Alamos, NM 87545 (United States)

    2014-11-11

    In the measurement field of international nuclear safeguards, passive neutron coincidence counting is used to quantify the spontaneous fission rate of certain special nuclear materials. The shift register autocorrelation analysis method is the most commonly used approach. However, the Feynman-Y technique, which is more commonly applied in reactor noise analysis, provides an alternative means to extract the correlation information from a pulse train. In this work we consider how to select the optimum gate width for each of these two time-correlation analysis techniques. The optimum is considered to be that which gives the lowest fractional precision on the net doublets rate. Our theoretical approach is approximate but is instructional in terms of revealing the key functional dependence. We show that in both cases the same performance figure of merit applies so that common design criteria apply to the neutron detector head. Our prediction is that near optimal results, suitable for most practical applications, can be obtained from both techniques using a common gate width setting. The estimated precision is also comparable in the two cases. The theoretical expressions are tested experimentally using {sup 252}Cf spontaneous fission sources measured in two thermal well counters representative of the type in common use by international inspectorates. Fast accidental sampling was the favored method of acquiring the Feynman-Y data. Our experimental study confirmed the basic functional dependences predicted although experimental results when available are preferred. With an appropriate gate setting Feynman-Y analysis provides an alternative to shift register analysis for safeguards applications which is opening up new avenues of data collection and data reduction to explore.

  15. Determination of trace elements in scallop and fish otolith by instrumental neutron activation analysis using anti-coincidence and coincidence counting methods

    International Nuclear Information System (INIS)

    Suzuki, Shogo; Okada, Yukiko; Hirai, Shoji

    2005-01-01

    Trace element concentrations in scallop reference material and fish otolith certified reference materials prepared at the National Institute for Environmental Studies (NIES) of Japan were determined by instrumental neutron activation analysis (INAA). Nine aliquots of scallop sample (ca. 252∼507 mg) and five aliquots of fish otolith sample (ca. 502 ∼ 988 mg) and comparative standards were irradiated for a short time (10 s) at a thermal neutron flux of 1.5 x 10 12 n cm -2 s -1 (pneumatic transfer) and for a long time (6 h) at a thermal neutron flux of 3.7 x 10 12 n cm -2 s -1 (central thimble) in the Rikkyo University Research Reactor (100 kW). The irradiated samples were measured by conventional γ-ray spectrometry using a coaxial Ge detector, and by anti-coincidence and coincidence γ-ray spectrometry with a coaxial Ge detector and a well-type NaI (Tl) detector to determine as many trace elements as possible with high sensitivity. The concentrations of 34 elements of the NIES No.15 scallop reference material and 16 elements of the NIES No.22 fish otolith CRM were determined. Using the coincidence counting method to determine Se, Ba and Hf, the lower limit of the determination was improved by 2 times compared with the conventional counting method. (author)

  16. Determination of cartilage thickness in the ankle joint. MRT (1,5 T) comparative anatomical study; Bestimmung der Knorpeldicke am oberen Sprunggelenk. Eine MRT(1,5 T)-anatomische Vergleichsstudie

    Energy Technology Data Exchange (ETDEWEB)

    Trattnig, S. [Universitaetsklinik fuer Radiodiagnostik, Wien (Austria). Klinische Einrichtung Magnet Resonanz und Abt. fuer Osteoradiologie]|[Ludwig Boltzmann Inst. fuer Radiologische Tumordiagnostik, Wien (Austria); Breitenseher, M.J. [Universitaetsklinik fuer Radiodiagnostik, Wien (Austria). Klinische Einrichtung Magnet Resonanz und Abt. fuer Osteoradiologie]|[Ludwig Boltzmann Inst. fuer Radiologische Tumordiagnostik, Wien (Austria); Huber, M. [Pathologisch-Bakteriologisches Inst. Baumgartner Hoehe, Wien (Austria); Zettl, R. [Orthopaedisches Krankenhaus Gersthof, Wien (Austria); Rottmann, B. [Universitaetsklinik fuer Radiodiagnostik, Wien (Austria). Klinische Einrichtung Magnet Resonanz und Abt. fuer Osteoradiologie]|[Ludwig Boltzmann Inst. fuer Radiologische Tumordiagnostik, Wien (Austria); Haller, J. [Hanuschkrankenhaus, Wien (Austria). Radiologische Abt.; Imhof, H. [Universitaetsklinik fuer Radiodiagnostik, Wien (Austria). Klinische Einrichtung Magnet Resonanz und Abt. fuer Osteoradiologie]|[Ludwig Boltzmann Inst. fuer Radiologische Tumordiagnostik, Wien (Austria)

    1997-04-01

    Purpose: The aim of this study was to evaluate the accuracy of MRI in the measurement of cartilage thickness of the ankle joint in comparison to pathologic and histologic specimens. Patients and methods: The ankle joints of four fresh cadaver feet were imaged on a 1.5 T MR-unit in the coronal plane. Standard T{sub 1}-weighted spin echo (SE) and a T{sub 1}-weighted 3D-GE (FLASH-3D) sequence with fat saturation were applied. Following MR imaging, the talus was explanted and cut parallel to the MR images for macroscopic evaluation and histologic specimens were prepared. MRI measurements of the cartilage thickness of the talus were carried out in two ways: Without and with consideration of a transition zone of intermediate signal intensity between hyperintense cartilage and hypointense cortical bone. The data were compared with the anatomic specimens as the gold standard expressing the difference as a percentage value. On histologic specimens thickness of deep calcified cartilage layer was measured. Results: Measurements without the transition zone showed a mean underestimation of talus cartilage thickness of 46.8% (41.3-52.1) for T{sub 1}-SE and 47.5% (43.1-52.1) for fat saturated FLASH-3D images. Considering the transition zone the mean values were 25.0% (23.1-26.2) and 14.1% (6.7-21.5). The histologic specimens showed a three-fold increase of thickness of deep calcified cartilage layer. Conclusions: Measurements of the cartilage layer of the ankle joint on MR images are only accurate if the transition zone (calcified cartilage layer) is considered and the optimal pulse sequence (FLASH-3D-fat-sat) is applied. (orig.) [Deutsch] Ziel: Die Frage, ob die MRT die Dicke des Knorpels exakt bestimmen kann, wird kontrovers diskutiert. Ziel der Studie war die Bestimmung der Knorpeldicke am oberen Sprunggelenk mit der MRT im Vergleich zum anatomischen Praeparat. Material und Methode: Sprunggelenke von 4 Leichen wurden auf einem 1,5 Tesla MR-Geraet mittels T{sub 1}-betonter Spin

  17. Performance Evaluation of the Neutron Coincidence Counter for the Advanced Spent Fuel Conditioning Process

    International Nuclear Information System (INIS)

    Lee, S.Y.; Li, T.K.; Menlove, Howard O.; Kim, H.D.; Ko, W.I.; Park, S.W.

    2005-01-01

    The Advanced Spent Fuel Conditioning Process (ACP) is a pyrochemical dry reprocessing technique to convert oxide-type spent nuclear fuel into a metallic form. The Korea Atomic Energy Research Institute (KAERI) has been developing this technology for the purpose of spent fuel management and is planning to perform a lab-scale demonstration in 2006. With this technology, a significant reduction of the volume and heat load of spent fuel is expected, which could decrease the burden of safety and economics. In this study, MCNPX code calculations were carried out to estimate the performance of a neutron coincidence counter designed for measruement of the process materials in the pilot-scale ACP facility. To verify the design requirement, the singles and doubles counting rates of the detectors were simulated with the latest coincidence capability of the MCNPX code. Then, the precision of the coincidence measurements were evaluated on various process materials from the ACP. It was verified that the performance of the neutron coincidence counter could meet the design criteria for all samples in the ACP, and the material accounting system for the pilot-scale ACP facility could meet the IAEA safeguards goals.

  18. Calculation of coincidence summing corrections for a specific small soil sample geometry

    Energy Technology Data Exchange (ETDEWEB)

    Helmer, R.G.; Gehrke, R.J.

    1996-10-01

    Previously, a system was developed at the INEL for measuring the {gamma}-ray emitting nuclides in small soil samples for the purpose of environmental monitoring. These samples were counted close to a {approx}20% Ge detector and, therefore, it was necessary to take into account the coincidence summing that occurs for some nuclides. In order to improve the technical basis for the coincidence summing corrections, the authors have carried out a study of the variation in the coincidence summing probability with position within the sample volume. A Monte Carlo electron and photon transport code (CYLTRAN) was used to compute peak and total efficiencies for various photon energies from 30 to 2,000 keV at 30 points throughout the sample volume. The geometry for these calculations included the various components of the detector and source along with the shielding. The associated coincidence summing corrections were computed at these 30 positions in the sample volume and then averaged for the whole source. The influence of the soil and the detector shielding on the efficiencies was investigated.

  19. CDL, a Precise, Low-Cost Coincidence Detector Latch

    Directory of Open Access Journals (Sweden)

    Ralf Joost

    2015-12-01

    Full Text Available The electronic detection of the coincidence of two events is still a key ingredient for high-performance applications, such as Positron Emission Tomography and Quantum Optics. Such applications are demanding, since the precision of their calculations and thus their conclusions directly depend on the duration of the interval in which two events are considered coincidental. This paper proposes a new circuitry, called coincidence detector latch (CDL, which is derived from standard RS latches. The CDL has the following advantages: low complexity, fully synthesizable, and high scalability. Even in its simple implementation, it achieves a coincidence window width as short as 115 ps, which is more than 10 times better than that reported by recent research.

  20. Metrology and statistical analysis for the precise standardisation of cobalt-60 by 4πβ-γ coincidence counting

    International Nuclear Information System (INIS)

    Buckman, S.M.

    1995-03-01

    The major part of the thesis is devoted to the theoretical development of a comprehensive PC-based statistical package for the analysis of data from coincidence-counting experiments. This analysis is applied to primary standardizations of Co performed in Australia and Japan. The Australian standardisation, the accuracy of which is confirmed through international comparison, is used to re-calibrate the ionisation chamber. Both Australian and Japanese coincidence-counting systems are interfaced to personal computers to enable replicated sets of measurements to be made under computer control. Further research to confirm the validity of the statistical model includes an experimental investigation into the non-Poisson behaviour of radiation detectors due to the effect of deadtime. Experimental investigation is conducted to determine which areas are most likely to limit the ultimate accuracy achievable with coincidence counting. The thesis concludes by discussing the possibilities of digital coincidence counting and outlines the design of a prototype system presently under development. The accuracy of the Australian standardisation is confirmed by international comparison. From this result a more accurate Co calibration is obtained for the Australian working standard. Based on the work of this thesis, uncertainties in coincidence counting experiments can be better handled with resulting improvements in measurement reliability. The concept and benefits of digital coincidence counting are discussed and a proposed design is given for such a system. All of the data and software associated with this thesis is provided on computer discs. 237 refs., figs., tabs

  1. On the structure of the set of coincidence points

    Energy Technology Data Exchange (ETDEWEB)

    Arutyunov, A V [Peoples Friendship University of Russia, Moscow (Russian Federation); Gel' man, B D [Voronezh State University (Russian Federation)

    2015-03-31

    We consider the set of coincidence points for two maps between metric spaces. Cardinality, metric and topological properties of the coincidence set are studied. We obtain conditions which guarantee that this set (a) consists of at least two points; (b) consists of at least n points; (c) contains a countable subset; (d) is uncountable. The results are applied to study the structure of the double point set and the fixed point set for multivalued contractions. Bibliography: 12 titles.

  2. On neutron activation analysis with γγ coincidence spectrometry

    International Nuclear Information System (INIS)

    Zeisler, Rolf; Danyal Turkoglu; Ibere Souza Ribeiro Junior; Shetty, M.G.

    2017-01-01

    A new γγ coincidence system has been set up at NIST. It is operated with a digital data finder supported by new software developed at NIST. The system is used to explore possible enhancements in instrumental neutron activation analysis (INAA) and study applicability to neutron capture prompt gamma activation analysis (PGAA). The performance of the system is tested with certified reference materials for efficiency calibration and quantitative performance. Comparisons of INAA results based on conventional gamma-ray spectrometry data with INAA results based on coincidence data obtained from the same samples show improvements in the counting uncertainties and demonstrates the quantitative accuracy of the new system. (author)

  3. Standardization of portable assay instrumentation: the neutron-coincidence tree

    International Nuclear Information System (INIS)

    Menlove, H.O.

    1983-01-01

    Standardization of portable neutron assay instrumentation has been achieved by using the neutron coincidence technique as a common basis for a wide range of instruments and applications. The electronics originally developed for the High-Level Neutron Coincidence Counter has been adapted to both passive- and active-assay instrumentation for field verification of bulk plutonium, inventory samples, pellets, powders, nitrates, high-enriched uranium, and materials-testing-reactor, light-water-reactor, and mixed-oxide fuel assemblies. The family of detectors developed at Los Alamos National Laboratory and their performance under in-field conditions are described. 16 figures, 3 tables

  4. Automatic classification of gammas-gamma coincidence matrices

    International Nuclear Information System (INIS)

    Los Arcos Merino, J. M.; Gonzalez, J. A.

    1978-01-01

    The information obtained during a coincidence experiment, recorded on magnetic tape by a MULTI-8 minicomputer, is transferred to a new tape in 36 bit words, using the program LEC0M8. The classification in two dimensional matrix form is carried out off-line, on a magnetic disk file, by the program CLAFI. On finishing classification one obtains a copy of the coincidence matrix on the second magnetic tape. Both programs are written to be processed in that order with the UNIVAC 1106 computer of J.E.N. (Author) 4 refs

  5. Automatic classification of gamma-gamma coincidence matrices

    International Nuclear Information System (INIS)

    Los Arcos Merino, J.M.; Gonzalez Gonzalez, J.A.

    1978-01-01

    The information obtained during a coincidence experiment, recorded on magnetic tape by a Multi-8 minicomputer, is transferred to a new tape in 36 bit words, using the program Lecom8. The classification in two dimensional matrix form is carried out off-line, on a magnetic disk file, by the program Clafi. On finishing classification one obtains a copy of the coincidence matrix on the second magnetic tape. Both programs are written to be processed in that order with the Univac 1106 computer of J.E.N. (author)

  6. Design of an electronic system with simultaneous registering of pulse amplitude and event time applied to the 4πβ-γ coincidence method

    International Nuclear Information System (INIS)

    Toledo, Fabio de

    2009-01-01

    The 4πβ-γ coincidence method for absolute radionuclide activity measurement has been considered for many years as a primary standard in Nuclear Metrology, because of dependence on few observable quantities and high accuracy. The Laboratorio de Metrologia Nuclear (LMN) - Nuclear Metrology Laboratory -, at Instituto de Pesquisas Energeticas e Nucleares (IPEN) - Nuclear and Energy Research Institute -, among its measurement techniques, uses the 4πβ-γ coincidence method. Recently a new technique known as 'software coincidence' has been used, with many advantages over the conventional coincidence methodology. In order to update the methodologies for radionuclide standardizations, the LMN developed a new system based on the software coincidence technique, described in the present work. This system uses the same nuclear set up for beta and gamma detection. The new software coincidence electronics uses a National Instruments (NI) acquisition card connected to a microcomputer and, through a connection panel, to the nuclear detection set up. The card configuration and controlling is accomplished by software using the LabVIEW, a NI proprietary product. This system records into disk files all the amplitudes and occurrence times for beta and gamma detected pulses. A suitable software was developed (the coincidence analysis program) to process the recorded data in order to obtain beta, gamma and coincidence counts and perform calculation of the radioactive source activity. The work also presents and discusses the results obtained with the first version of the coincidence analysis program, as well as perspectives for future works. (author)

  7. Coincident Observations of Surface Ozone and NMVOCs over Abu Dhabi

    Science.gov (United States)

    Abbasi, Naveed; Majeed, Tariq; Iqbal, Mazhar; Tarasick, David; Davies, Jonathan; Riemer, Daniel; Apel, Eric

    2016-07-01

    The vertical profiles of ozone are measured coincidently with non-methane volatile organic compounds (NMVOCs) at the meteorological site located at the Abu Dhabi international airport (latitude 24.45N; longitude 54.22E) during the years 2012 - 2014. Some of the profiles show elevated surface ozone >95 ppbv during the winter months (December, January and February). The ground-level NMVOCs obtained from the gas chromatography-flame ionization detection/mass spectrometry system also show elevated values of acetylene, ethane, propane, butane, pentane, benzene, and toluene. NMVOCs and ozone abundances in other seasons are much lower than the values in winter season. NMVOCs are emitted from an extensive number of sources in urban environments including fuel production, distribution, and consumption, and serve as precursor of ozone. Transport sources contribute a substantial portion of the NMVOC burden to the urban atmosphere in developed regions. Abu Dhabi is located at the edge of the Arabian Gulf and is highly affected by emissions from petrochemical industries in the neighboring Gulf region. The preliminary results indicate that wintertime enhancement in ozone is associated with large values of NMVOCs at Abu Dhabi. The domestic production of surface ozone is estimated from the combination of oxygen recombination and NMVOCs and compared with the data. It is estimated that about 40-50% of ozone in Abu Dhabi is transported from the neighbouring petrochemical industries. We will present ozone sounding and NMVOCs data and our model estimates of surface ozone, including a discussion on the high levels of the tropospheric ozone responsible for contaminating the air quality in the UAE. This work is supported by National Research Foundation, UAE.

  8. Development of Coincidence Method for Determination Thermal Neutron Flux on RSG-GAS

    International Nuclear Information System (INIS)

    Bakhri, Syaiful; Hamzah, Amir

    2004-01-01

    The research to develop detection radiation system using coincidence method has been done to determine thermal neutron flux in RS1 and RS2 irradiation facilities RSG-GAS. At this research has arranged beta-gamma coincidence equipment system and parameter of measurement according to Au-198 beta-gamma spectrum. Gold foils that have irradiated for period of time, counted, and the activities of radiation is analyzed to get neutron flux. Result of research indicate that systems measurement of absolute activity with gamma beta coincidence method functioning well and can be applied at activity measurement of gold foil for irradiation facility characterization. The results show that thermal neutron flux in RS1 and RS2, respectively is 2.007E+12 n/cm 2 s and 2.147E+12 n/cm 2 s. To examine the system performance, the result was compared to measure activity using high resolution of Hp Ge detector and achieved discrepancy is about 1.26% and 6.70%. (author)

  9. Unattended mode monitoring of passive neutron coincidence detector systems using a commercial data logger

    International Nuclear Information System (INIS)

    Smith, B.G.R.; Outram, J.D.; Storey, M.

    1991-01-01

    A commercial Data Logger for unattended passive neutron coincidence data acquisition is described. This consists of an inexpensive commercial Data Logging equipment attached to a neutron coincidence electronics and a software package for data review. The Data Logger permits both the flexible configuration of a passive neutron coincidence measurement system for unattended mode monitoring and the storage of the measured Totals and Reals count rates. An additional feature of the Data Logger is a custom software package providing for the complete analysis of the stored data and yielding an assay of each item passing through the measurement cavity. The analysis includes an input for different isotopic compositions, the calculation of the multiplication corrected Reals rates, the inclusion of a calibration functions, and the determination of 240 Pu masses. The software package for data review displays the Totals and Reals count rates logged by the Data Logger as a function of time. In addition the custom software provides input files to the data review package to display the multiplication corrected Reals count rates and the measured 240 Pu masses as a function of time. Information on the Data Logger is presented along with the monitoring mode specifications. The analysis functions implemented are described as is the data review software. Results are presented for a specific application

  10. Standardisation of {sup 18}F by a coincidence method using full solid angle detectors

    Energy Technology Data Exchange (ETDEWEB)

    Nedjadi, Youcef, E-mail: youcef.nedjadi@chuv.c [Institut de Radiophysique Appliquee, Grand Pre 1, 1007 Lausanne (Switzerland); Bailat, Claude; Caffari, Yvan; Bochud, Francois [Institut de Radiophysique Appliquee, Grand Pre 1, 1007 Lausanne (Switzerland)

    2010-07-15

    A solution of {sup 18}F was standardised with a 4{pi}{beta}-4{pi}{gamma} coincidence counting system in which the beta detector is a one-inch diameter cylindrical UPS89 plastic scintillator, positioned at the bottom of a well-type 5''x5'' NaI(Tl) gamma-ray detector. Almost full detection efficiency-which was varied downwards electronically-was achieved in the beta-channel. Aliquots of this {sup 18}F solution were also measured using 4{pi}{gamma} NaI(Tl) integral counting and Monte Carlo calculated efficiencies as well as the CIEMAT-NIST method. Secondary measurements of the same solution were also performed with an IG11 ionisation chamber whose equivalent activity is traceable to the Systeme International de Reference through the contribution IRA-METAS made to it in 2001; IRA's degree of equivalence was found to be close to the key comparison reference value (KCRV). The {sup 18}F activity predicted by this coincidence system agrees closely with the ionisation chamber measurement and is compatible within one standard deviation of the other primary measurements. This work demonstrates that our new coincidence system can standardise short-lived radionuclides used in nuclear medicine.

  11. Photoelectron photoion coincidence imaging of ultrafast control in multichannel molecular dynamics.

    Science.gov (United States)

    Lehmann, C Stefan; Ram, N Bhargava; Irimia, Daniel; Janssen, Maurice H M

    2011-01-01

    The control of multichannel ionic fragmentation dynamics in CF3I is studied by femtosecond pulse shaping and velocity map photoelectron photoion coincidence imaging. When CF3I is photoexcited with femtosecond laser pulses around 540 nm there are two major ions observed in the time-of-flight mass spectrum, the parent CF3I+ ion and the CF3+ fragment ion. In this first study we focussed on the influence of LCD-shaped laser pulses on the molecular dynamics. The three-dimensional recoil distribution of electrons and ions were imaged in coincidence using a single time-of-flight delay line detector. By fast switching of the voltages on the various velocity map ion lenses after detection of the electron, both the electron and the coincident ion are measured with the same imaging detector. These results demonstrate that a significant simplification of a photoelectron-photoion coincidence imaging apparatus is in principle possible using switched lens voltages. It is observed that shaped laser fields like chirped pulses, double pulses, and multiple pulses can enhance the CF3+CF3I+ ratio by up to 100%. The total energetics of the dynamics is revealed by analysis of the coincident photoelectron spectra and the kinetic energy of the CF3+ and I fragments. Both the parent CF3I+ and the CF3+ fragment result from a five-photon excitation process. The fragments are formed with very low kinetic energy. The photoelectron spectra and CF3+/CF3I+ ratio vary with the center wavelength of the shaped laser pulses. An optimal enhancement of the CF3+/CF3I+ ratio by about 60% is observed for the double pulse excitation when the pulses are spaced 60 fs apart. We propose that the control mechanism is determined by dynamics on neutral excited states and we discuss the results in relation to the location of electronically excited (Rydberg) states of CF3I.

  12. Standardization of 56Co had been carried out using 4 pi beta-gamma coincidence methods

    International Nuclear Information System (INIS)

    Wardiyanto, Gatot; Pujadi

    2000-01-01

    Standardization of exp.56 Co had been carried out using 4 pi beta-gamma coincidence methods. The radionuclide use for calibration of nuclear instruments on range of energy over 1500 keV. The exp.56 Co had been produced by irradiation of proton by using a cyclotron with 15 MeV of energy and 300 mb of cross-section to natural iron target (99,5% of purity) at the Institute for Nuclear Study, University of Tokyo. Source preparation had been done by gravimetry method after the irradiated source was dissolved in 8N HCI solution. The disintegration rate had been measured using 4 pi beta-gamma coincidence apparatus, where the gamm gets sets on 511 and 847 keV gamma-rays. The result measurement is fairly good with the specific activity is 3078 n 15 Bq/mg

  13. Performance evaluation of BGO block detectors used in positron emission tomography and a coincidence system

    International Nuclear Information System (INIS)

    Kim, J. H.; Choi, Y.; Lim, K. C.; Lee, M. Y.; Woo, S. K.; Lee, K. H.; Kim, S. E.; Choi, Y. S.; Kim, B. T.

    1999-01-01

    We investigated the basic performances of the BGO block detectors, which is used in the GE Advance positron emission tomography. The block detector is composed of 36 small BGO crystals coupled to two 2-channel photomultiplier tubes. In this study, we measured the crystal map and the intrinsic energy resolution of the detector. The coincidence signals between the detectors were also obtained using F-18. The intrinsic energy resolution of the block detector was 69% FWHM at 140 keV and 33% FWHM at 511 keV. High quality crystal map and the coincidence signals between the detectors were successfully obtained. The timing resolution of the detectors are being measured. The results of this study demonstrate the feasibility of developing high performance positron emission tomography

  14. Studies of weak capture-gamma-ray resonances via coincidence techniques

    CERN Document Server

    Rowland, C; Champagne, A E; Dummer, A K; Fitzgerald, R; Harley, E C T; Mosher, J; Runkle, R

    2002-01-01

    A method for measuring weak capture-gamma-ray resonances via gamma gamma-coincidence counting techniques is described. The coincidence apparatus consisted of a large-volume germanium detector and an annular NaI(Tl) crystal. The setup was tested by measuring the weak E sub R =227 keV resonance in sup 2 sup 6 Mg(p,gamma) sup 2 sup 7 Al. Absolute germanium and NaI(Tl) counting efficiencies for a range of gamma-ray energies and for different detector-target geometries are presented. Studies of the gamma-ray background in our spectra are described. Compared to previous work, our method improves the detection sensitivity for weak capture-gamma-ray resonances by a factor of approx 100. The usefulness of the present technique for investigations of interest to nuclear astrophysics is discussed.

  15. Optical Co-Incidence Gate | Srinivasulu | African Journal of Science ...

    African Journals Online (AJOL)

    The paper explains Optical co-incidence gate, realized using Unijunction transistors (UJT), Light emitting diodes (LED) and Photo-resistors (LDR), which works on 1.8Vdc instead of 3Vdc. The power dissipation of the designed gate is only 3 mW. This optical gate finds application in the field of Mechatronics, Instrumentation ...

  16. Analysis of (HI, xnγ) coincidence spectra

    International Nuclear Information System (INIS)

    Pattabiraman, N.S.; Ghugre, S.S.; Chintalapudi, S.N.

    2000-01-01

    The increase in the sensitivity and the detection limits of the modern third generation gamma detector arrays, has made it necessary to properly understand and estimate the observed background in such experiments. The present paper extends the two algorithms to improve the genuine photo-peak-photo-peak coincident events of interest

  17. A {beta} - {gamma} coincidence; Metodo de coincidencias {beta} - {gamma}

    Energy Technology Data Exchange (ETDEWEB)

    Agullo, F

    1960-07-01

    A {beta} - {gamma} coincidence method for absolute counting is given. The fundamental principles are revised and the experimental part is detailed. The results from {sup 1}98 Au irradiated in the JEN 1 Swimming pool reactor are given. The maximal accuracy is 1 per cent. (Author) 11 refs.

  18. Light particles emitted in coincidence with evaporation residues in 79Br(930 MeV) + 27Al collisions

    International Nuclear Information System (INIS)

    Chavez Lomeli, E.; Dacal, A.; Ortiz, M.E.; Gomez del Campo, J.; Kim, H.; Korolija, M.; Shapira, D.

    1993-01-01

    Exclusive measurements of light particles, deuterons, tritons and alphas, in coincidence with Evaporation Residues (ER), were performed at the Holified Heavy Ion Research Facility of the Oak Ridge National Laboratory using the large detector array HILI (Heavy Ion Light Ion). Heavy fragments produced in the reaction (Z 35), were stopped in the Ionisation Chamber, where their energy, atomic number (Z) and position were measured. Coincident light particles, were detected in the 192 element hodoscope placed behind the chamber, where its charge (Z) and energy were measured. Also the time of flight relative to the radio frequency of the cyclotron, allowed identification of protons deuterons and tritons

  19. The origin of narrowing of the Si 2p coincidence photoelectron spectroscopy main line of Si(1 0 0) surface

    International Nuclear Information System (INIS)

    Ohno, Masahide

    2011-01-01

    Highlights: → The Si 2p coincidence photoelectron spectroscopy (PES) main line of Si(1 0 0) is calculated. → The PES main line shows an asymmetric line shape change compared to the singles one. → The narrowing of the coincidence Si 2p PES main line is well reproduced. → The inherent mechanism of APECS is explained by a many-body theory. - Abstract: The Si 2p photoelectron spectroscopy (PES) main line of Si(1 0 0) surface measured in coincidence with the singles (noncoincidence) Si L 2,3 -VV Auger-electron spectroscopy (AES) elastic peak is calculated. The agreement with the experiment is good. The present work is the first many-body calculation of the experimental coincidence PES spectrum of solid surface. The narrowing of the coincidence Si 2p PES main line compared to the singles one is due to the mechanism inherent in the coincidence PES. The inherent mechanism is explained by a many-body theory by which photoemission and Auger-electron emission are treated on the same footing.

  20. Modeling of LMM-MVV Auger-Auger Coincidence Spectra From Solids

    Science.gov (United States)

    Sundaramoorthy, R.; Weiss, A. H.; Hulbert, S. L.; Bartynski, R. A.

    2006-03-01

    Atoms that are highly excited due to the presence of a hole in an inner shell often relax via an Auger transition. This auto-ionizing process results in a final state with two or more holes from an Auger cascade. We present results of the direct measurements of the second and third Auger decays in this sequence. We have measured the Mn MVV Auger spectra from a single-crystal sample of MnO in time coincidence with Auger electrons emitted from prior Mn LMM Auger decays and find these to be much wider than the MVV spectrum measured in time coincidence with M core photoelectron emission. We present a model which attributes the increased energy width of the MVV transitions that follow LMM decays to the rearrangement of ``not so innocent'' bystander hole(s) in the valence band. The energetics of the Auger cascade process are modeled mathematically in terms of correlation integral(s) and convolution integral(s) over the valence band density of states. Comparisons with recent Auger-Auger coincidence studies of Ag and Pd will be made. Acknowledgements: Welch Foundation, NSF DMR98-12628, NSF DMR98-01681, and DOE DE-AC02-98CH10886.

  1. Coincidence study of alpha particle fragmentation at E/sub alpha/ = 140 MeV

    International Nuclear Information System (INIS)

    Koontz, R.W.

    1980-01-01

    Results of an experimental study of the interaction of 140 MeV alpha particles with 90 Zr nuclei resulting in fragmentation of the alpha particle are reported. The experimental observations of the study are analyzed and are found to show that alpha particle breakup reactions leading to at least 4-body final states, composed of two charged alpha particle fragments, contribute significantly to the singles yield of charged fragments observed at a fixed forward angle. The conclusions are based on coincidence measurements where one charged fragment is detected at a small forward angle which remains fixed, while the second charged fragment is detected at a series of coplanar secondary angles. The largest coincidence charged particle yield for the multiparticle final state events results from 90 Zr(α,pp)X reactions, where both of the measured protons have energy distributions similar to the proton singles energy distributions. The second largest observed coincidence yield involving two charged fragments arises from 90 Zr(α,pd)X reactions, where the p and d fragments, as in the 90 Zr(α,pp)X reactions also have energy distribution similar to the singles energy distributions. Analysis of additional measurements, where alpha particle fragments at the fixed angle are detected in coincidence with evaporation and nonequilibrium particles at many coplanar angles, show that the alpha particle fragmentation reactions are also generally associated with large energy transfer to the target nucleus. A multiple scattering model of the fragmentation reaction is employed, in conjunction with the experimental observations, to estimate the cross sections for alpha particle fragmentation into multi-particle final states resulting in n, 2n, p, pp, d, dn, dp, t and 3 He fragments. The estimated total cross section for all fragmentation reactions is 755 mb or approximately 38% of the total reaction cross section for 140 MeV alpha particle interactions with 90 Zr

  2. A deadtime reduction circuit for thermal neutron coincidence counters with Amptek preamplifiers

    International Nuclear Information System (INIS)

    Bourret, S.C.; Krick, M.S.

    1994-01-01

    We have developed a deadtime reduction circuit for thermal neutron coincidence counters using Amptek preamplifier/amplifier/discriminator circuits. The principle is to remove the overlap between the output pulses from the Amptek circuits by adding a derandomizer between the Amptek circuits and the shift-register coincidence electronics. We implemented the derandomizer as an Actel programmable logic array; the derandomizer board is small and can be mounted in the high-voltage junction box with the Amptek circuits, if desired. Up to 32 Amptek circuits can be used with one derandomizer. The derandomizer has seven outputs: four groups of eight inputs, two groups of 16 inputs, and one group of 32 inputs. We selected these groupings to facilitate detector ring-ratio measurements. The circuit was tested with the five-ring research multiplicity counter, which has five output signals-one for each ring. The counter's deadtime was reduced from 70 to 30 ns

  3. Use of γ-γ coincidence spectrometry in the geochemical study of diamictites from South Africa

    International Nuclear Information System (INIS)

    Huber, H.; Koeberl, Ch.; McDonald, I.; Reimold, W.U.

    2000-01-01

    γ-γ coincidence spectrometry was used to investigate the possible presence of a meteoritical component in 27 samples of South African diamictites. Recently, several studies have suggested that some tillites/diamictites may represent impact breccias, but a petrographical study by our group found no evidence for the presence of impact-characteristic shocked minerals. The siderophile elements, such as Cr, Co, Ni, and, especially, the platinum group elements, have high abundances in meteorites, but low abundances in terrestrial crustal rocks. The Ir content of the diamictites was measured with the new iridium coincidence spectrometer (ICS) at the University of Vienna, with detection limits of around 0.02 ppb. No enrichments in the contents of Ir and other siderophile elements compared to average crustal concentrations were found; thus, no unequivocal evidence for an impact origin of these diamictites of the South African Dwyka Group can be documented. (author)

  4. Interaction of multicharged ions with molecules (CO2, C60) by coincident electron spectroscopy

    International Nuclear Information System (INIS)

    Moretto-Capelle, P.; Bordenave-Montesquieu, D.; Bordenave-Montesquieu, A.

    2001-01-01

    First results for the investigation of electron capture processes in collisions between multicharged ions and molecule targets using electron spectroscopy in coincidence with charged fragments, are presented. It is shown that a much more detailed investigation of the capture reaction can be achieved using molecular instead of heavy atomic targets provided that an analysis of the target dissociation is made. The collisional systems 18 O 8+ +Ar, CO 2 and C 60 have been studied at 80 keV. Non coincident electron spectra as well as first results of double or triple coincidence experiments are discussed. Kinetic energy distributions of the C n + fragments (n=1 to 8) produced in multiple capture processes from C 60 target are given. A detailed investigation of the double capture process with CO 2 molecule allows the measurement of kinetic energy release distributions (KERD) which characterize the dissociation of CO 2 2+ molecular ions; our results are found to be very similar to those measured in double photoionisation experiments. (orig.)

  5. Many-body calculation of the coincidence L3 photoelectron spectroscopy main line of Ni metal

    International Nuclear Information System (INIS)

    Ohno, Masahide

    2008-01-01

    The partial singles L 3 photoelectron spectroscopy (PES) main line of Ni metal correlated with Auger electrons emitted by the localized L 3 -VV Auger decay is calculated by a many-body theory. The partial singles L 3 PES main line of Ni metal almost coincides in both line shape and peak kinetic energy (KE) with the singles one. The former main line peak shows a KE shift of only 0.01 eV toward the lower KE and a very small asymmetric line shape change compared to the singles one. The asymmetric line shape change and the peak KE shift of the partial singles L 3 main line are very small. However, they are due to the variation with photoelectron KE in the branching ratio of the partial Auger decay width in the partial singles L 3 PES main line by the photoelectron KE dependent imaginary part of the shakeup self-energy. The L 3 PES main line of Ni metal measured in coincidence with the L 3 -VV ( 1 G) Auger electron spectroscopy (AES) main line peak is the partial singles one modulated by a spectral function R a of a fixed energy Auger electron analyzer so that it should show only a symmetric line narrowing by R a compared to the singles one. The L 3 PES main line peak of Ni metal measured in coincidence with the delocalized band-like L 3 -VV AES peak or not completely split-off (or not completely localized) L 3 -VV ( 3 F) AES peak, will show an asymmetric line narrowing and a KE shift compared to the singles one. Thus, the L 3 PES main line of Ni metal in coincidence with various parts of the L 3 -VV AES spectrum depends on which part of the L 3 -VV AES spectrum a fixed energy Auger electron analyzer is set. The experimental verification is in need

  6. Device for multi-dimensional γ-γ-coincidence study

    International Nuclear Information System (INIS)

    Gruzinova, T.M.; Erokhina, K.I.; Kutuzov, V.I.; Lemberg, I.Kh.; Petrov, S.A.; Revenko, V.S.; Senin, A.T.; Chugunov, I.N.; Shishlinov, V.M.

    1977-01-01

    A device for studying multi-dimensional γ-γ coincidences is described which operates on-line with the BESM-4 computer. The device comprises Ge(Li) detectors, analog-to-digital converters, shaper discriminators and fast amplifiers. To control the device operation as a whole and to elaborate necessary commands, an information distributor has been developed. The following specific features of the device operation are noted: the device may operate both in the regime of recording spectra of direct γ radiation in the block memory of multi-channel analyzer, and in the regime of data transfer to the computer memory; the device performs registration of coincidences; it transfers information to the computer which has a channel of direct access to the memory. The procedure of data processing is considered, the data being recorded on a magnetic tape. Partial spectra obtained are in a good agreement with data obtained elsewhere

  7. Alpha-Photon Coincidence Spectroscopy Along Element 115 Decay Chains

    Energy Technology Data Exchange (ETDEWEB)

    Rudolph, D. [Lund Univ., Lund (Sweden); Forsberg, U. [Lund Univ., Lund (Sweden); Golubev, P. [Lund Univ., Lund (Sweden); Sarmiento, L. G. [Lund Univ., Lund (Sweden); Yakushev, A. [GSI Helmholtzzentrum fur Schwerionenforschung GmbH, Darmstadt (Germany); Andersson, L. -L. [Helmholtz Institute Mainz, Mainz (Germany); Di Nitto, A. [Johannes Gutenberg-Univ. Mainz, Mainz (Germany); Dullmann, Ch. E. [GSI Helmholtzzentrum fur Schwerionenforschung GmbH, Darmstadt (Germany); Helmholtz Institute Mainz, Mainz (Germany); Johannes Gutenberg-Univ. Mainz, Mainz (Germany); Gates, J. M. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Gregorich, K. E. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Gross, C. J. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Herzberg, R. -D. [Univ. of Liverpool, Liverpool (United Kingdom); Hessberger, F. P. [GSI Helmholtzzentrum fur Schwerionenforschung GmbH, Darmstadt (Germany); Helmholtz Institute Mainz, Mainz (Germany); Khuyagbaatar, J. [Helmholtz Institute Mainz, Mainz (Germany); Kratz, J. V. [Johannes Gutenberg-Univ. Mainz, Mainz (Germany); Rykaczewski, K. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Schadel, M. [GSI Helmholtzzentrum fur Schwerionenforschung GmbH, Darmstadt (Germany); Japan Atomic Energy Agency, Tokai (Japan); Aberg, S. [Lund Univ., Lund (Sweden); Ackermann, D. [GSI Helmholtzzentrum fur Schwerionenforschung GmbH, Darmstadt (Germany); Block, M. [GSI Helmholtzzentrum fur Schwerionenforschung GmbH, Darmstadt (Germany); Brand, H. [GSI Helmholtzzentrum fur Schwerionenforschung GmbH, Darmstadt (Germany); Carlsson, B. G. [Lund Univ., Lund (Sweden); Cox, D. [Univ. of Liverpool, Liverpool (United Kingdom); Derkx, X. [Helmholtz Institute Mainz, Mainz (Germany); Johannes Gutenberg-Univ. Mainz, Mainz (Germany); Eberhardt, K. [Helmholtz Institute Mainz, Mainz (Germany); Johannes Gutenberg-Univ. Mainz, Mainz (Germany); Even, J. [Helmholtz Institute Mainz, Mainz (Germany); Fahlander, C. [Lund Univ., Lund (Sweden); Gerl, J. [GSI Helmholtzzentrum fur Schwerionenforschung GmbH, Darmstadt (Germany); Jager, E. [GSI Helmholtzzentrum fur Schwerionenforschung GmbH, Darmstadt (Germany); Kindler, B. [GSI Helmholtzzentrum fur Schwerionenforschung GmbH, Darmstadt (Germany); Krier, J. [GSI Helmholtzzentrum fur Schwerionenforschung GmbH, Darmstadt (Germany); Kojouharov, I. [GSI Helmholtzzentrum fur Schwerionenforschung GmbH, Darmstadt (Germany); Kurz, N. [GSI Helmholtzzentrum fur Schwerionenforschung GmbH, Darmstadt (Germany); Lommel, B. [GSI Helmholtzzentrum fur Schwerionenforschung GmbH, Darmstadt (Germany); Mistry, A. [Univ. of Liverpool, Liverpool (United Kingdom); Mokry, C. [Helmholtz Institute Mainz, Mainz (Germany); Johannes Gutenberg-Univ. Mainz, Mainz (Germany); Nitsche, H. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Omtvedt, J. P. [Univ. of Oslo, Oslo (Norway); Papadakis, P. [Univ. of Liverpool, Liverpool (United Kingdom); Ragnarsson, I. [Lund Univ., Lund (Sweden); Runke, J. [GSI Helmholtzzentrum fur Schwerionenforschung GmbH, Darmstadt (Germany); Schaffner, H. [GSI Helmholtzzentrum fur Schwerionenforschung GmbH, Darmstadt (Germany); Schausten, B. [GSI Helmholtzzentrum fur Schwerionenforschung GmbH, Darmstadt (Germany); Thorle-Pospiech, P. [Helmholtz Institute Mainz, Mainz (Germany); Johannes Gutenberg-Univ. Mainz, Mainz (Germany); Torres, T. [GSI Helmholtzzentrum fur Schwerionenforschung GmbH, Darmstadt (Germany); Traut, T. [Johannes Gutenberg-Univ. Mainz, Mainz (Germany); Trautmann, N. [Johannes Gutenberg-Univ. Mainz, Mainz (Germany); Turler, A. [Paul Scherrer Institute and Univ. of Bern, Villigen (Switzerland); Ward, A. [Univ. of Liverpool, Liverpool (United Kingdom); Ward, D. E. [Lund Univ., Lund (Sweden); Wiehl, N. [Helmholtz Institute Mainz, Mainz (Germany); Johannes Gutenberg-Univ. Mainz, Mainz (Germany)

    2014-01-01

    Produced in the reaction 48Ca+ 243Am, thirty correlated α-decay chains were observed in an experiment conducted at the GSI Helmholzzentrum für Schwerionenforschung, Darmstadt, Germany. The decay chains are basically consistent with previous findings and are considered to originate from isotopes of element 115 with mass numbers 287, 288, and 289. A set-up aiming specifically for high-resolution charged particle and photon coincidence spectroscopy was placed behind the gas-filled separator TASCA. For the first time, γ rays as well as X-ray candidates were observed in prompt coincidence with the α-decay chains of element 115.

  8. Delivery of parameterization schemes for the determination of the regional evapotranspiration of different land surfaces. Final report; Bereitstellung von Parameterisierungsverfahren zur Bestimmung der regionalen Verdunstung verschiedener Landoberflaechen. Abschlussbericht 1997

    Energy Technology Data Exchange (ETDEWEB)

    Haenel, H.D.; Loepmeier, F.J.

    1998-03-01

    The task was the delivery of parameterization schemes for the calculation of the regional evapotranspiration of different land surfaces. The main weight was on the discussion of existing approaches and on the development of new ones for the calculation of evapotranspiration. After consideration of different concepts the well-known Penman-Monteith equation proved to the optimal basis of calculation. The surface resistance, respectively the related bulk-stomata resistance, is an important part of the resistance pattern (analogous to Ohm`s law) on which the Penman-Monteith equation is based. Under consideration of the dependence of these resistances of the spatial scale (leaf, canopy) as well as of the time scale (hour, day) possibilities for their estimation were discussed. An important step to determine the surface resistances from literature data of vegetation evapotranspiration was the development of a converting scheme of Haude`s factors to surface resistances. For bare soil an approach was developed which allows approximately to give a new interpretation to surface resistances from evapotranspiration courses, described in literature as proportional to the square root of time. (orig.) [Deutsch] Die Aufgabenstellung bestand in der Bereitstellung von Parametrisierungsverfahren zur Bestimmung der regionalen Verdunstung verschiedener Landoberflaechen. Dabei lag das Schwergewicht auf der Diskussion bereits bestehender und der Entwicklung neuer Ansaetze zur Berechnung der Verdunstung. Nach der Betrachtung unterschiedlicher Konzepte erwies sich die bekannte Penman-Monteith-Gleichung als optimale Berechnungsgrundlage. Ein wesentlicher Bestandteil des der Penman-Monteith-Gleichung zugrundeliegenden Widerstandsschemas (Analogie zum Ohmschen Gesetz) ist der Oberflaechenwiderstand bzw. der damit verwandte Bulk-Stomatawiderstand. Unter Beruecksichtigung der Abhaengigkeit dieser Widerstaende sowohl von der raeumlichen Skala (Blatt/Bestand) als auch von der zeitlichen Skala

  9. Coincidence of asthma and bronchospasm during anesthesia in tympanomastoidectomy.

    OpenAIRE

    Nima Hosseinzadeh; Shahram Samadi; Amin Amali; Mihan Jafari Javid

    2014-01-01

    High prevalence of asthma and bronchospasm was observed during induction of anesthesia in patients with chronic suppurative otitis mMedia (CSOM) who underwent tympanomastoidectomy. Although several studies have proposed association of allergic diseases with CSOM but no consensus about it has been established. Current study was designed to determine the coincidence of asthma in CSOM patients. In a cross-sectional study, authors investigated medical records of 106 CSOM patients underwent tympan...

  10. Energy and depth resolution in elastic recoil coincidence spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Szilagyi, E., E-mail: szilagyi@rmki.kfki.h [KFKI Research Institute for Particle and Nuclear Physics, P.O. Box 49, H-1525 Budapest (Hungary)

    2010-06-15

    Elastic recoil coincidence spectrometry was implemented into the analytical ion beam simulation program DEPTH. In the calculations, effective detector geometry and multiple scattering effects are considered. Mott's cross section for the identical, spin zero particles is included. Spectra based on the individual detector signal and summing the energy of the recoiled and scattered particles originating from the same scattering events can also be calculated. To calculate this latter case, the dependency of the energy spread contributions had to be reconsidered.

  11. Energy and depth resolution in elastic recoil coincidence spectrometry

    International Nuclear Information System (INIS)

    Szilagyi, E.

    2010-01-01

    Elastic recoil coincidence spectrometry was implemented into the analytical ion beam simulation program DEPTH. In the calculations, effective detector geometry and multiple scattering effects are considered. Mott's cross section for the identical, spin zero particles is included. Spectra based on the individual detector signal and summing the energy of the recoiled and scattered particles originating from the same scattering events can also be calculated. To calculate this latter case, the dependency of the energy spread contributions had to be reconsidered.

  12. Coincidence summing corrections for positron emitters in germanium gamma spectrometry

    International Nuclear Information System (INIS)

    Richardson, A.E.; Sallee, W.W.; New Mexico State Univ., Las Cruces

    1990-01-01

    For positron emitters, 511 keV annihilation quanta are in coincidence with other gamma rays in the decay scheme. If the positrons are not localized at the point of decay, annihilation quanta will be produced at a site some distance from the point of emission. The magnitude of the summing coincidence effect will depend upon the position of annihilation. A method for determining the magnitude of the summing effect for a single gamma of energy E in coincidence with the annihilation gammas from non-localized positrons has been developed which makes use of the counting data for the full energy peaks for both the gamma ray (E) and the 511 keV annihilation gammas. With this data and efficiency calibration data one can determine the average total efficiency for the annihilation positions from which 511 keV gammas originate, and thereby obtain the summing correction factor, SCF, for gamma ray (E). Application of the method to a 22 Na NIST standard gave excellent agreement of observed emission rates for the 1275 keV gamma with the NIST value for wide ranging degrees of positron localization having summing correction factors ranging from 1.021 to 1.505. The method was also applied successfully to 58 Co in neutron-irradiated nickel foils. The method shows promise as a check on the accuracy of the efficiency calibration for a particular detector geometry at the 511 keV energy and energies for other gammas associated with positron emission. (orig.)

  13. High sensitivity neutron activation analysis using coincidence counting method

    International Nuclear Information System (INIS)

    Suzuki, Shogo; Okada, Yukiko; Hirai, Shoji

    1999-01-01

    Four kinds of standard samples such as river sediment (NIES CRM No.16), Typical Japanese Diet, otoliths and river water were irradiated by TRIGA-II (100 kW, 3.7x10 12 n cm -2 s -1 ) for 6 h. After irradiation and cooling, they were analyzed by the coincidence counting method and a conventional γ-ray spectrometry. Se, Ba and Hf were determined by 75 Se 265 keV, 131 Ba 496 keV and 181 Hf 482 keV. On the river sediment sample, Ba and Hf showed the same values by two methods, but Se value contained Ta by the conventional method, although the coincidence counting method could analyze Se. On Typical Japanese Diet and otoliths, Se could be determined by two methods and Ba and Hf determined by the coincidence counting method but not determined by the conventional method. Se value in the river water agreed with the authorization value. (S.Y.)

  14. Post training REMs coincident auditory stimulation enhances memory in humans.

    Science.gov (United States)

    Smith, C; Weeden, K

    1990-06-01

    Sleep activity was monitored in 20 freshman college students for two consecutive nights. Subjects were assigned to 4 equal groups and all were asked to learn a complex logic task before bed on the second night. Two groups of subjects learned the task with a constant clicking noise in the background (cued groups), while two groups simply learned the task (non cued). During the night, one cued and one non cued group were presented with auditory clicks during REM sleep such as to coincide with all REMs of at least 100 microvolts. The second cued group was given auditory clicks during REM sleep, but only during the REMs "quiet" times. The second non-cued control group was never given any nighttime auditory stimulations. The cued REMs coincident group showed a significant 23% improvement in task performance when tested one week later. The non cued REMs coincident group showed only an 8.8% improvement which was not significant. The cued REMs quiet and non-stimulated control groups showed no change in task performance when retested. The results were interpreted as support for the idea that the cued auditory stimulation induced a "recall" of the learned material during the REM sleep state in order for further memory processing to take place.

  15. Silicon PIN diode based electron-gamma coincidence detector system for Noble Gases monitoring.

    Science.gov (United States)

    Khrustalev, K; Popov, V Yu; Popov, Yu S

    2017-08-01

    We present a new second generation SiPIN based electron-photon coincidence detector system developed by Lares Ltd. for use in the Noble Gas measurement systems of the International Monitoring System and the On-site Inspection verification regimes of the Comprehensive Nuclear-Test Ban Treaty (CTBT). The SiPIN provide superior energy resolution for electrons. Our work describes the improvements made in the second generation detector cells and the potential use of such detector systems for other applications such as In-Situ Kr-85 measurements for non-proliferation purposes. Copyright © 2017 Elsevier Ltd. All rights reserved.

  16. Frequencies of mutagen-induced coincident mitotic recombination at unlinked loci in Saccharomyces cerevisiae

    Energy Technology Data Exchange (ETDEWEB)

    Freeman, Kathryn M. [Department of Biology, College of the Holy Cross, One College Street, Worcester, MA 01610-2395 (United States); Hoffmann, George R. [Department of Biology, College of the Holy Cross, One College Street, Worcester, MA 01610-2395 (United States)]. E-mail: ghoffmann@holycross.edu

    2007-03-01

    Frequencies of coincident genetic events were measured in strain D7 of Saccharomyces cerevisiae. This diploid strain permits the detection of mitotic gene conversion involving the trp5-12 and trp5-27 alleles, mitotic crossing-over and gene conversion leading to the expression of the ade2-40 and ade2-119 alleles as red and pink colonies, and reversion of the ilv1-92 allele. The three genes are on different chromosomes, and one might expect that coincident (simultaneous) genetic alterations at two loci would occur at frequencies predicted by those of the single alterations acting as independent events. Contrary to this expectation, we observed that ade2 recombinants induced by bleomycin, {beta}-propiolactone, and ultraviolet radiation occur more frequently among trp5 convertants than among total colonies. This excess among trp5 recombinants indicates that double recombinants are more common than expected for independent events. No similar enrichment was found among Ilv{sup +} revertants. The possibility of an artifact in which haploid yeasts that mimic mitotic recombinants are generated by a low frequency of cryptic meiosis has been excluded. Several hypotheses that can explain the elevated incidence of coincident mitotic recombination have been evaluated, but the cause remains uncertain. Most evidence suggests that the excess is ascribable to a subset of the population being in a recombination-prone state.

  17. Observation of relaxation on time scale of core hole decay by coincidence photoelectron spectroscopy

    International Nuclear Information System (INIS)

    Ohno, Masahide

    2007-01-01

    It is shown by a many-body theory that when the relaxation time of a metastable core hole state(s) to the most stable one is comparable to or shorter than core hole decay time of the former state(s), a comparison between the singles (noncoincidence) photoelectron spectroscopy (PES) spectrum and the coincidence one provides a direct evidence of the relaxation. In principle the variation with photoelectron kinetic energy of relaxation (or charge transfer (CT)) time can be determined. By singles measurement the correlation of a photoelectron generated by creation of the metastable states not only with an Auger electron generated by annihilation of the same core hole state but also with an Auger electron generated by annihilation of the stable state via relaxation of the metastable state, is completely lost, unless only the metastable state is observed by PES, whereas the correlation often manifests directly in the coincidence spectra. Thus, compared to the coincidence spectroscopy the singles one is often much less capable of elucidating the competition between relaxation and core hole decay of a metastable state. Such examples are discussed

  18. Frequencies of mutagen-induced coincident mitotic recombination at unlinked loci in Saccharomyces cerevisiae

    International Nuclear Information System (INIS)

    Freeman, Kathryn M.; Hoffmann, George R.

    2007-01-01

    Frequencies of coincident genetic events were measured in strain D7 of Saccharomyces cerevisiae. This diploid strain permits the detection of mitotic gene conversion involving the trp5-12 and trp5-27 alleles, mitotic crossing-over and gene conversion leading to the expression of the ade2-40 and ade2-119 alleles as red and pink colonies, and reversion of the ilv1-92 allele. The three genes are on different chromosomes, and one might expect that coincident (simultaneous) genetic alterations at two loci would occur at frequencies predicted by those of the single alterations acting as independent events. Contrary to this expectation, we observed that ade2 recombinants induced by bleomycin, β-propiolactone, and ultraviolet radiation occur more frequently among trp5 convertants than among total colonies. This excess among trp5 recombinants indicates that double recombinants are more common than expected for independent events. No similar enrichment was found among Ilv + revertants. The possibility of an artifact in which haploid yeasts that mimic mitotic recombinants are generated by a low frequency of cryptic meiosis has been excluded. Several hypotheses that can explain the elevated incidence of coincident mitotic recombination have been evaluated, but the cause remains uncertain. Most evidence suggests that the excess is ascribable to a subset of the population being in a recombination-prone state

  19. 3D Silicon Coincidence Avalanche Detector (3D-SiCAD) for charged particle detection

    Science.gov (United States)

    Vignetti, M. M.; Calmon, F.; Pittet, P.; Pares, G.; Cellier, R.; Quiquerez, L.; Chaves de Albuquerque, T.; Bechetoille, E.; Testa, E.; Lopez, J.-P.; Dauvergne, D.; Savoy-Navarro, A.

    2018-02-01

    Single-Photon Avalanche Diodes (SPADs) are p-n junctions operated in Geiger Mode by applying a reverse bias above the breakdown voltage. SPADs have the advantage of featuring single photon sensitivity with timing resolution in the picoseconds range. Nevertheless, their relatively high Dark Count Rate (DCR) is a major issue for charged particle detection, especially when it is much higher than the incoming particle rate. To tackle this issue, we have developed a 3D Silicon Coincidence Avalanche Detector (3D-SiCAD). This novel device implements two vertically aligned SPADs featuring on-chip electronics for the detection of coincident avalanche events occurring on both SPADs. Such a coincidence detection mode allows an efficient discrimination of events related to an incoming charged particle (producing a quasi-simultaneous activation of both SPADs) from dark counts occurring independently on each SPAD. A 3D-SiCAD detector prototype has been fabricated in CMOS technology adopting a 3D flip-chip integration technique, and the main results of its characterization are reported in this work. The particle detection efficiency and noise rejection capability for this novel device have been evaluated by means of a β- strontium-90 radioactive source. Moreover the impact of the main operating parameters (i.e. the hold-off time, the coincidence window duration, the SPAD excess bias voltage) over the particle detection efficiency has been studied. Measurements have been performed with different β- particles rates and show that a 3D-SiCAD device outperforms single SPAD detectors: the former is indeed capable to detect particle rates much lower than the individual DCR observed in a single SPAD-based detectors (i.e. 2 to 3 orders of magnitudes lower).

  20. Development, implementation and validation of a practice-orientated method for the determination of yields of biogas or methane, respectively; Entwicklung, Implementierung und Validierung eines praxisnahen Verfahrens zur Bestimmung von Biogas- bzw. Methanertraegen

    Energy Technology Data Exchange (ETDEWEB)

    Fritz, Thomas

    2008-12-15

    The increasing number of the world population results in a pronounced ascent of the world-wide energy consumption. This problem additionally is strengthened by the release of carbon dioxide. In the contribution under consideration, the author develops a method with which the yields of fermentation gas or methane, respectively, reliably as well as practice-orientated can be determined. Different influences on the determination of these yields are described. Thus, the investigations in this area are to be standardised further. The comparability under laboratories is to be increased. (orig.) [German] Die steigende Zahl der Weltbevoelkerung fuehrt zu einem Ausgepraegten Anstieg des weltweiten Energieverbrauchs. Diese Problematik wird durch die Freisetzung von Kohlendioxid zusaetzlich verstaerkt. Im vorliegenden Beitrag entwickelt der Autor eine Methode, mit der die Ertraege von Biogas beziehungsweise Methan zuverlaesslich und praxisnah bestimmt werden koennen. Es werden verschiedene Einfluesse auf die Bestimmung dieser Ertraege dargestellt. Damit sollen die Untersuchungen auf diesem Gebiet weiter standardisiert und die Vergleichbarkeit unter Laboren erhoeht werden.

  1. Imaging photoelectron circular dichroism of chiral molecules by femtosecond multiphoton coincidence detection

    Energy Technology Data Exchange (ETDEWEB)

    Lehmann, C. Stefan; Ram, N. Bhargava; Janssen, Maurice H. M., E-mail: m.h.m.janssen@vu.nl [LaserLaB Amsterdam, VU University Amsterdam, De Boelelaan 1081, 1081 HV Amsterdam (Netherlands); Powis, Ivan [School of Chemistry, University of Nottingham, Nottingham NG7 2RD (United Kingdom)

    2013-12-21

    Here, we provide a detailed account of novel experiments employing electron-ion coincidence imaging to discriminate chiral molecules. The full three-dimensional angular scattering distribution of electrons is measured after photoexcitation with either left or right circular polarized light. The experiment is performed using a simplified photoelectron-photoion coincidence imaging setup employing only a single particle imaging detector. Results are reported applying this technique to enantiomers of the chiral molecule camphor after three-photon ionization by circularly polarized femtosecond laser pulses at 400 nm and 380 nm. The electron-ion coincidence imaging provides the photoelectron spectrum of mass-selected ions that are observed in the time-of-flight mass spectra. The coincident photoelectron spectra of the parent camphor ion and the various fragment ions are the same, so it can be concluded that fragmentation of camphor happens after ionization. We discuss the forward-backward asymmetry in the photoelectron angular distribution which is expressed in Legendre polynomials with moments up to order six. Furthermore, we present a method, similar to one-photon electron circular dichroism, to quantify the strength of the chiral electron asymmetry in a single parameter. The circular dichroism in the photoelectron angular distribution of camphor is measured to be 8% at 400 nm. The electron circular dichroism using femtosecond multiphoton excitation is of opposite sign and about 60% larger than the electron dichroism observed before in near-threshold one-photon ionization with synchrotron excitation. We interpret our multiphoton ionization as being resonant at the two-photon level with the 3s and 3p Rydberg states of camphor. Theoretical calculations are presented that model the photoelectron angular distribution from a prealigned camphor molecule using density functional theory and continuum multiple scattering X alpha photoelectron scattering calculations

  2. Coincident brane nucleation and the neutralization of Λ

    International Nuclear Information System (INIS)

    Garriga, Jaume; Megevand, Ariel

    2004-01-01

    Nucleation of branes by a four-form field has recently been considered in string motivated scenarios for the neutralization of the cosmological constant. An interesting question in this context is whether the nucleation of stacks of coincident branes is possible, and if so, at what rate does it proceed. Feng et al. have suggested that, at high ambient de Sitter temperature, the rate may be strongly enhanced, due to large degeneracy factors associated with the number of light species living on the worldsheet. This might facilitate the quick relaxation from a large effective cosmological constant down to the observed value. Here, we analyze this possibility in some detail. In four dimensions, and after the moduli are stabilized, branes interact via repulsive long range forces. Because of that, the Coleman-de Luccia (CdL) instanton for coincident brane nucleation may not exist, unless there is some short range interaction that keeps the branes together. If the CdL instanton exists, we find that the degeneracy factor depends only mildly on the ambient de Sitter temperature, and does not switch off even in the case of tunneling from flat space. This would result in catastrophic decay of the present vacuum. If, on the contrary, the CdL instanton does not exist, coincident brane nucleation may still proceed through a 'static' instanton, representing pair creation of critical bubbles--a process somewhat analogous to thermal activation in flat space. In that case, the branes may stick together due to thermal symmetry restoration, and the pair creation rate depends exponentially on the ambient de Sitter temperature, switching off sharply as the temperature approaches zero. Such a static instanton may be well suited for the 'saltatory' relaxation scenario proposed by Feng et al

  3. An evaluation of the influence of γ-γ angular correlation on the coincidence-summing corrections in γ-ray spectrometry

    International Nuclear Information System (INIS)

    Roteta, M.; Garcia-Torano, E.

    1996-01-01

    The effect of angular correlation on coincidence-summing corrections has been evaluated for three detectors (planar Ge, coaxial Ge and well NaI), at different measurement geometries and for some selected radionuclides. For the detectors and nuclides studied, it can be concluded that the effect of angular correlation on coincidence-summing corrections can be neglected if the radioactive source is measured either in contact with the detector or at large distances. (orig.)

  4. Reconstructed Image Spatial Resolution of Multiple Coincidences Compton Imager

    Science.gov (United States)

    Andreyev, Andriy; Sitek, Arkadiusz; Celler, Anna

    2010-02-01

    We study the multiple coincidences Compton imager (MCCI) which is based on a simultaneous acquisition of several photons emitted in cascade from a single nuclear decay. Theoretically, this technique should provide a major improvement in localization of a single radioactive source as compared to a standard Compton camera. In this work, we investigated the performance and limitations of MCCI using Monte Carlo computer simulations. Spatial resolutions of the reconstructed point source have been studied as a function of the MCCI parameters, including geometrical dimensions and detector characteristics such as materials, energy and spatial resolutions.

  5. High-level neutron coincidence counter maintenance manual

    International Nuclear Information System (INIS)

    Swansen, J.; Collinsworth, P.

    1983-05-01

    High-level neutron coincidence counter operational (field) calibration and usage is well known. This manual makes explicit basic (shop) check-out, calibration, and testing of new units and is a guide for repair of failed in-service units. Operational criteria for the major electronic functions are detailed, as are adjustments and calibration procedures, and recurrent mechanical/electromechanical problems are addressed. Some system tests are included for quality assurance. Data on nonstandard large-scale integrated (circuit) components and a schematic set are also included

  6. Coincident systemic lupus erythematosus and psoriasis vulgaris: a case report.

    Science.gov (United States)

    Wang, Y; Da, G; Yu, Y; Han, J; Li, H

    2015-12-01

    Psoriasis vulgaris is an autoimmune chronic inflammatory skin disease, but its association with other typical autoimmune disease such as systemic lupus erythematosus has only occasionally been reported. We presented a 25-year-old female who developed systemic lupus erythematosus associated with psoriasis vulgaris. Her conditions were in good control after she got administration of prednisolone (5 mg/day) and Tripterygium Wilfordii Hook (20 mg/day). It is necessary to integrate past history and physical examination to diagnose coincident SLE and psoriasis, and combined treatment with prednisolone and Tripterygium Wilfordii Hook proves effective.

  7. High-level neutron coincidence counter maintenance manual

    Energy Technology Data Exchange (ETDEWEB)

    Swansen, J.; Collinsworth, P.

    1983-05-01

    High-level neutron coincidence counter operational (field) calibration and usage is well known. This manual makes explicit basic (shop) check-out, calibration, and testing of new units and is a guide for repair of failed in-service units. Operational criteria for the major electronic functions are detailed, as are adjustments and calibration procedures, and recurrent mechanical/electromechanical problems are addressed. Some system tests are included for quality assurance. Data on nonstandard large-scale integrated (circuit) components and a schematic set are also included.

  8. A new 4π(LS)-γ coincidence counter at NCBJ RC POLATOM with TDCR detector in the beta channel.

    Science.gov (United States)

    Ziemek, T; Jęczmieniowski, A; Cacko, D; Broda, R; Lech, E

    2016-03-01

    A new 4π(LS)-γ coincidence system (TDCRG) was built at the NCBJ RC POLATOM. The counter consists of a TDCR detector in the beta channel and scintillation detector with NaI(Tl) crystal in the gamma channel. The system is equipped with a digital board with FPGA, which records and analyses coincidences in the TDCR detector and coincidences between the beta and gamma channels. The characteristics of the system and a scheme of the FPGA implementation with behavioral simulation are given. The TDCRG counter was validated by activity measurements on (14)C and (60)Co solutions standardized in RC POLATOM using previously validated methods. Copyright © 2015 Elsevier Ltd. All rights reserved.

  9. COINCIDENCES BETWEEN ELECTRONS AND TARGET IONS TO IDENTIFY CAPTURE CHANNELS IN COLLISIONS OF MULTIPLY CHARGED IONS ON GAS TARGETS

    NARCIS (Netherlands)

    POSTHUMUS, JH; MORGENSTERN, R

    1992-01-01

    We have investigated multielectron capture processes in collisions of Ar9+ on Ar by measuring the resulting Auger electrons in coincidence with charge-state-analyzed target ions. In this way it was possible to reconstruct partial electron energy spectra, each corresponding to a particular number of

  10. Coincidence of lung cancer and silicosis in Czechoslovak uranium miners

    International Nuclear Information System (INIS)

    Urban, S.; Urbanova, S.

    1988-01-01

    27 patients with established coincidence of lung cancer and silicosis from a group of 1607 cases of lung cancer from radioactive compounds, and 166 cases of pneumoconiosis were reported by the Occupational Diseases Ward of the works Institute of National Health in Uranium Industry in the 1962 to 1986 years. Lung cancer was found in 16% of reported silicosis patients, in 81% it was simple silicosis, in 50% of cases in was an epidermoid type of cancer. In two cases the malignant process originated in the silicotic node, in one case from a tuberculoma. Lung cancer occurred most frequently in the right lower lung region. The mean age of the silicosis group was 48.6 years and 56.0 years for the lung cancer group. No difference was thus seen from the mean age of patients with lung cancer from radioactive compounds diagnosed in the years 1976 to 1980 but it was significantly lower that the reported average age of patients with coincidence of lung cancer and pneumoconiosis in the population not exposed to ionizing radiation. (author). 2 figs., 1 tab., 18 refs

  11. Coincidence Detection Using Spiking Neurons with Application to Face Recognition

    Directory of Open Access Journals (Sweden)

    Fadhlan Kamaruzaman

    2015-01-01

    Full Text Available We elucidate the practical implementation of Spiking Neural Network (SNN as local ensembles of classifiers. Synaptic time constant τs is used as learning parameter in representing the variations learned from a set of training data at classifier level. This classifier uses coincidence detection (CD strategy trained in supervised manner using a novel supervised learning method called τs Prediction which adjusts the precise timing of output spikes towards the desired spike timing through iterative adaptation of τs. This paper also discusses the approximation of spike timing in Spike Response Model (SRM for the purpose of coincidence detection. This process significantly speeds up the whole process of learning and classification. Performance evaluations with face datasets such as AR, FERET, JAFFE, and CK+ datasets show that the proposed method delivers better face classification performance than the network trained with Supervised Synaptic-Time Dependent Plasticity (STDP. We also found that the proposed method delivers better classification accuracy than k nearest neighbor, ensembles of kNN, and Support Vector Machines. Evaluation on several types of spike codings also reveals that latency coding delivers the best result for face classification as well as for classification of other multivariate datasets.

  12. Cochlear spike synchronization and neuron coincidence detection model

    Science.gov (United States)

    Bader, Rolf

    2018-02-01

    Coincidence detection of a spike pattern fed from the cochlea into a single neuron is investigated using a physical Finite-Difference model of the cochlea and a physiologically motivated neuron model. Previous studies have shown experimental evidence of increased spike synchronization in the nucleus cochlearis and the trapezoid body [Joris et al., J. Neurophysiol. 71(3), 1022-1036 and 1037-1051 (1994)] and models show tone partial phase synchronization at the transition from mechanical waves on the basilar membrane into spike patterns [Ch. F. Babbs, J. Biophys. 2011, 435135]. Still the traveling speed of waves on the basilar membrane cause a frequency-dependent time delay of simultaneously incoming sound wavefronts up to 10 ms. The present model shows nearly perfect synchronization of multiple spike inputs as neuron outputs with interspike intervals (ISI) at the periodicity of the incoming sound for frequencies from about 30 to 300 Hz for two different amounts of afferent nerve fiber neuron inputs. Coincidence detection serves here as a fusion of multiple inputs into one single event enhancing pitch periodicity detection for low frequencies, impulse detection, or increased sound or speech intelligibility due to dereverberation.

  13. Coincidence-anticipation timing requirements are different in racket sports.

    Science.gov (United States)

    Akpinar, Selçuk; Devrilmez, Erhan; Kirazci, Sadettin

    2012-10-01

    The aim of this study was to compare the coincidence-anticipation timing accuracy of athletes of different racket sports with various stimulus velocity requirements. Ninety players (15 girls, 15 boys for each sport) from tennis (M age = 12.4 yr., SD = 1.4), badminton (M age = 12.5 yr., SD = 1.4), and table tennis (M age = 12.4 yr., SD = 1.2) participated in this study. Three different stimulus velocities, low, moderate, and high, were used to simulate the velocity requirements of these racket sports. Tennis players had higher accuracy when they performed under the low stimulus velocity compared to badminton and table tennis players. Badminton players performed better under the moderate speed comparing to tennis and table tennis players. Table tennis players had better performance than tennis and badminton players under the high stimulus velocity. Therefore, visual and motor systems of players from different racket sports may adapt to a stimulus velocity in coincidence-anticipation timing, which is specific to each type of racket sports.

  14. Calibration and performance testing of the IAEA Aquila Active Well Coincidence Counter (Unit 1)

    International Nuclear Information System (INIS)

    Menlove, H.O..; Siebelist, R.; Wenz, T.R.

    1996-01-01

    An Active Well Coincidence Counter (AWCC) and a portable shift register (PSR-B) produced by Aquila Technologies Group, Inc., have been tested and cross-calibrated with existing AWCCs used by the International Atomic Energy Agency (IAEA). This report summarizes the results of these tests and the cross-calibration of the detector. In addition, updated tables summarizing the cross-calibration of existing AWCCs and AmLi sources are also included. Using the Aquila PSR-B with existing IAEA software requires secondary software also supplied by Aquila to set up the PSR-B with the appropriate measurement parameters

  15. A note on the local cosmological constant and the dark energy coincidence problem

    International Nuclear Information System (INIS)

    Tajmar, M

    2006-01-01

    It has been suggested that the dark energy coincidence problem could be interpreted as a possible link between the cosmological constant and a massive graviton. We show that by using this link and models for the graviton mass, a dark energy density can be obtained that is indeed very close to measurements by WMAP. As a consequence of the models, the cosmological constant was found to depend on the density of matter. A brief outline of the cosmological consequences such as the effect on the black hole solution is given. (comments, replies and notes)

  16. Fluorescent atom coincidence spectroscopy of extremely neutron-deficient barium isotopes

    International Nuclear Information System (INIS)

    Wells, S.A.; Evans, D.E.; Griffith, J.A.R.; Eastham, D.A.; Groves, J.; Smith, J.R.H.; Tolfree, D.W.L.; Warner, D.D.; Billowes, J.; Grant, I.S.; Walker, P.M.

    1988-01-01

    Fluorescent atom coincidence spectroscopy (FACS) has been used to measure the nuclear mean square radii and moments of the extremely neutron-deficient isotopes 120-124 Ba. At N=65 an abrupt change in nuclear mean square charge radii is observed which can be understood in terms of the occupation of the spin-orbit partner g 7/2 5/2[413] neutron and g 9/2 9/2[404] proton orbitals and the consequent enhancement of the n-p interaction. (orig.)

  17. Deconvolution of 2D coincident Doppler broadening spectroscopy using the Richardson-Lucy algorithm

    International Nuclear Information System (INIS)

    Zhang, J.D.; Zhou, T.J.; Cheung, C.K.; Beling, C.D.; Fung, S.; Ng, M.K.

    2006-01-01

    Coincident Doppler Broadening Spectroscopy (CDBS) measurements are popular in positron solid-state studies of materials. By utilizing the instrumental resolution function obtained from a gamma line close in energy to the 511 keV annihilation line, it is possible to significantly enhance the quality of the CDBS spectra using deconvolution algorithms. In this paper, we compare two algorithms, namely the Non-Negativity Least Squares (NNLS) regularized method and the Richardson-Lucy (RL) algorithm. The latter, which is based on the method of maximum likelihood, is found to give superior results to the regularized least-squares algorithm and with significantly less computer processing time

  18. Method for improving the gamma-transition cascade spectra amplitude resolution during coincidence code computerized processing

    International Nuclear Information System (INIS)

    Sukhovoj, A.M.; Khitrov, V.A.

    1984-01-01

    A method of unfolding the differential γ-cascade spectra during radiation capture of slow neutrons based on the computeri-- zed processing of the results of measurements performed, by means of a spectrometer with two Ge(Li) detectors is suggested. The efficiency of the method is illustrated using as an example the spectrum of 35 Cl(n, γ) reaction corresponding to the 8580 keV peak. It is shown that the above approach permits to improve the resolution by 1.2-2.6 times without decrease in registration efficiency within the framework of the method of coincidence pulse amplitude summation

  19. Studies of the electron-impact double-ionisation process in magnesium using coincidence techniques

    International Nuclear Information System (INIS)

    Ford, M.J.

    1998-01-01

    This article will review recent measurements of the electron-impact double-ionisation of atomic magnesium. Results for the resonant Auger double-ionisation process with coincident detection of all three outgoing electrons, the (e, 3e) experiment, and for the direct double-ionisation process where only two outgoing electrons are detected, the (e, (3 -1)e) experiment, will be discussed. The results are analysed with reference to ionisation mechanisms and comparisons are made with calculated double-ionisation cross sections. Copyright (1998) CSIRO Australia

  20. Method for the determination of the radon entry rate inside buildings; Methodik zur Bestimmung der Radonquellstaerke in Gebaeuden

    Energy Technology Data Exchange (ETDEWEB)

    Neugebauer, T.; Hingmann, H.; Buermeyer, J.; Grimm, V.; Spruck, K.; Breckow, J. [Technische Hochschule Mittelhessen (THM), Giessen (Germany). Inst. fuer Medizinische Physik und Strahlenschutz (IMPS)

    2016-07-01

    The radon entry rate describes the radon characteristics of a building, which are defined by its constructional condition (tightness of building envelope) and the geological realities (radon soil gas concentration). All possible radon sources of a building are considered. The determination of the radon entry rate is based on the measurement of the radon concentration inside a building and the determination of the air change rate. The air change rate can be calculated via several approaches, VDI 4300-7 provides the most common methods. The main approaches are based on the use of a tracer gas, which concentration is measured over the time. In a first attempt, a one-time and punctual injection of a tracer gas was used. A disadvantage was that the air change rate could be determined only for short periods. In the follow-up, the constant injection of a tracer gas at multiple spots was executed. With this method, it is possible to calculate the air change rate over several weeks on a continuous base; the data can be used to determine the radon entry rate. Based on those series of measurements a first analysis of possible dependencies of the radon entry rate was performed.

  1. Calculating the share of process energy consumed by biomass conversion plants. Bestimmung der Anteile der Prozessenergie bei einer Biogasanlage

    Energy Technology Data Exchange (ETDEWEB)

    Goebel, W

    1984-06-01

    During the winter season the process energy consumption of biomass conversion plants is relatively high. Apart from the quantity and temperature of manures and insulation of the fermentation tank the process energy consumption depends on the efficiency of the heating system. Moreover, heat losses decide on the required quantities of process energy. Compared with the process energy consumption the electric power consumption of the engines supplying the biomass conversion plant is relatively low. Along with calculations tests and measurements in a biomass conversion plant during the winter season of 1981/1982 give access to the interrelation between process energy and electric power consumption.

  2. Fast procedures for coincidence-summing correction in γ-ray spectrometry

    International Nuclear Information System (INIS)

    De Felice, Pierino; Angelini, Paola; Fazio, Aldo; Biagini, Roberto

    2000-01-01

    Simplified and fast procedures for coincidence-summing correction in γ-ray spectrometry were investigated. These procedures are based on the usual theoretical expressions of the correction factors, but differ in the determination of the total efficiency curve based on the following approximations: (a) replacement, below the knee efficiency value, of the total efficiency by the full-energy peak efficiency; and (b) use of linear interpolations (in log-log plot) between only two experimental points above the knee efficiency value; or (c) assumption of a peak-to-total efficiency ratio independent on the counting geometry; or (d) assumption of a constant relation between the peak-to-total efficiency ratios and the photoelectric-to-total cross section ratios. The above approximations were separately assumed for determination of the coincidence-summing correction factors for nuclides with complex decay scheme ( 133 Ba, 134 Cs, 152 Eu) and for 60 Co and 88 Y measured on a 15% relative efficiency p-type coaxial HPGe detector, for three source-detector geometries: point source placed on top of and at 10 cm from the detector window, and 1 l Marinelli beaker filled with aqueous solution. The results were compared with those based on more accurate experimental determinations of the total efficiency curve from measurements of standard sources of eight different single-γ-ray emitters. The usefulness of each simplified procedure is evaluated with respect to its accuracy and to the reduction of the number of standard sources and measurement time

  3. Untersuchung vom Myonen aus semileptonischen Zo- Zerfaellen - Bestimmung der partiellen b-Quark-Breite und der Fragmentierungsfunktion

    CERN Document Server

    Ueberschaer, Stefan

    1992-01-01

    Hadronic final states in e+e- annihilation at y's ~ mz, collected 1990/91 by the DELPHI detector at LEP, have been analysed. Results about the fragmentation functions of b-quarks, the bb partial width rbb and the semileptonic branching ration BsL(b-+μ) have been obtained. The tagging of b-quark events has been performed using the semileptonic decay channel b-+ X+μ. To measure the product of the Z 0 decay width to bb and the branching fraction of the the b-quark to muons together with the mean scaled energy of the B-hadron, the observed two-dimensional PT versus p distribution of muons has been fitted. The experimental results obtained from approximately 16 000 analysed events are:...The quoted errors combine statistical and systematical uncertainties.

  4. A high-efficiency neutron coincidence counter for small samples

    International Nuclear Information System (INIS)

    Miller, M.C.; Menlove, H.O.; Russo, P.A.

    1991-01-01

    The inventory sample coincidence counter (INVS) has been modified to enhance its performance. The new design is suitable for use with a glove box sample-well (in-line application) as well as for use in the standard at-line mode. The counter has been redesigned to count more efficiently and be less sensitive to variations in sample position. These factors lead to a higher degree of precision and accuracy in a given counting period and allow for the practical use of the INVS counter with gamma-ray isotopics to obtain a plutonium assay independent of operator declarations and time-consuming chemicals analysis. A calculation study was performed using the Los Alamos transport code MCNP to optimize the design parameters. 5 refs., 7 figs., 8 tabs

  5. Positron emission tomography with gamma camera in coincidence mode

    International Nuclear Information System (INIS)

    Hertel, A.; Hoer, G.

    1999-01-01

    Positron emission tomography using F-18 FDG has been estbalished in clinical diagnostics with first indications especially in oncology. To install a conventional PET tomography (dedicated PET) is financially costly and restricted to PET examinations only. Increasing demand for PET diagnostics on one hand and restricted financial resources in the health system on the other hand led industry to develop SPECT cameras to be operated in coincidence mode (camera PET) in order to offer nuclear medicine physicians cost-effective devices for PET diagnostic. At the same time camera PET is inferior to conventional PET regarding sensitivity and detection-efficiency for 511 keV photons. Does camera-PET offer a reliable alternative to conventional PET? The first larger comparative studies are now available, so a first apraisal about the technical clinical performance of camera-PET can be done. (orig.) [de

  6. Airborne LIDAR borsight error calibration based on surface coincide

    International Nuclear Information System (INIS)

    Yuan, Fangyan; Li, Guoqing; Zuo, Zhengli; Li, Dong; Qi, Zengying; Qiu, Wen; Tan, Junxiang

    2014-01-01

    Light Detection and Ranging (LIDAR) is a system which can directly collect three-dimensional coordinate information of ground point and laser reflection strength information. With the wide application of LIDAR system, users hope to get more accurate results. Boresight error has an important effect on data accuracy and thus, it is thought that eliminating the error is very important. In recent years, many methods have been proposed to eliminate the error. Generally, they can be categorized into tie point method and surface matching method. In this paper, we propose another method called try value method based on surface coincide that is used in actual production by many companies. The method is simple and operable. Further, the efficacy of the method was demonstrated by analyzing the data from Zhangye city

  7. On the spatial coincidence of hydroxyl and methanol masers

    Science.gov (United States)

    Hartquist, T. W.; Menten, K. M.; Lepp, S.; Dalgarno, A.

    1995-01-01

    We argue that purely gas-phase chemical models for the production of OH in hydroxyl masers around ultracompact H II regions such as W3(OH) cannot account for the CH_3OH in the methanol masers that are found to coincide with the hydroxyl masers in these sources. We suggest that the CH_3OH in the masers is injected into the gas phase by evaporation of the grain mantles, the grains being heated by the passage of weak shocks. Gas evaporation also injects H_2O into the gas. Photodissociation of H_2O, CH_3OH and OH occur at similar rates, and substantial abundances of CH_3OH and OH coexist.

  8. Optimized coincidence Doppler broadening spectroscopy using deconvolution algorithms

    International Nuclear Information System (INIS)

    Ho, K.F.; Ching, H.M.; Cheng, K.W.; Beling, C.D.; Fung, S.; Ng, K.P.

    2004-01-01

    In the last few years a number of excellent deconvolution algorithms have been developed for use in ''de-blurring'' 2D images. Here we report briefly on one such algorithm we have studied which uses the non-negativity constraint to optimize the regularization and which is applied to the 2D image like data produced in Coincidence Doppler Broadening Spectroscopy (CDBS). The system instrumental resolution functions are obtained using the 514 keV line from 85 Sr. The technique when applied to a series of well annealed polycrystalline metals gives two photon momentum data on a quality comparable to that obtainable using 1D Angular Correlation of Annihilation Radiation (ACAR). (orig.)

  9. Testable solution of the cosmological constant and coincidence problems

    International Nuclear Information System (INIS)

    Shaw, Douglas J.; Barrow, John D.

    2011-01-01

    We present a new solution to the cosmological constant (CC) and coincidence problems in which the observed value of the CC, Λ, is linked to other observable properties of the Universe. This is achieved by promoting the CC from a parameter that must be specified, to a field that can take many possible values. The observed value of Λ≅(9.3 Gyrs) -2 [≅10 -120 in Planck units] is determined by a new constraint equation which follows from the application of a causally restricted variation principle. When applied to our visible Universe, the model makes a testable prediction for the dimensionless spatial curvature of Ω k0 =-0.0056(ζ b /0.5), where ζ b ∼1/2 is a QCD parameter. Requiring that a classical history exist, our model determines the probability of observing a given Λ. The observed CC value, which we successfully predict, is typical within our model even before the effects of anthropic selection are included. When anthropic selection effects are accounted for, we find that the observed coincidence between t Λ =Λ -1/2 and the age of the Universe, t U , is a typical occurrence in our model. In contrast to multiverse explanations of the CC problems, our solution is independent of the choice of a prior weighting of different Λ values and does not rely on anthropic selection effects. Our model includes no unnatural small parameters and does not require the introduction of new dynamical scalar fields or modifications to general relativity, and it can be tested by astronomical observations in the near future.

  10. Bestimmung der fehlenden transversalen Energie auf der ersten Triggerstufe beim ATLAS-Experiment und Optimierung der Triggerselektion von supersymmetrischen Ereignissen

    CERN Document Server

    Rieke, Stefan

    2009-01-01

    The standard model (SM) of particle physics is a theory, describing three out of four fundamental forces. The prediction of the standard model are in good agreement with the results of measurement of the experiments at the CERN, the Fermi lab and other research establishments. Still, not all open questions of the particle physics could be answered with this model. For example, it is not possible to implement the fourth fundamental force, the gravity, into the SM. Another example are candidates for the dark matter, which couldn’t described by the standard model, but cosmological experiments show that the contribution of the dark matter is about 25% of the universe. The supersymmetry, which introduce a symmetry between fermions and bosons, is regarded as one of the most promising solution for these open questions. In this theory, each new particle so-called supersymmetric particles is related to one particle in the standard model. If supersymmetry is realized in nature, one possible model of this symmetry is ...

  11. Corrections for the effects of accidental coincidences, Compton scatter, and object size in positron emission mammography (PEM) imaging

    Science.gov (United States)

    Raylman, R. R.; Majewski, S.; Wojcik, R.; Weisenberger, A. G.; Kross, B.; Popov, V.

    2001-06-01

    Positron emission mammography (PEM) has begun to show promise as an effective method for the detection of breast lesions. Due to its utilization of tumor-avid radiopharmaceuticals labeled with positron-emitting radionuclides, this technique may be especially useful in imaging of women with radiodense or fibrocystic breasts. While the use of these radiotracers affords PEM unique capabilities, it also introduces some limitations. Specifically, acceptance of accidental and Compton-scattered coincidence events can decrease lesion detectability. The authors studied the effect of accidental coincidence events on PEM images produced by the presence of /sup 18/F-Fluorodeoxyglucose in the organs of a subject using an anthropomorphic phantom. A delayed-coincidence technique was tested as a method for correcting PEM images for the occurrence of accidental events. Also, a Compton scatter correction algorithm designed specifically for PEM was developed and tested using a compressed breast phantom. Finally, the effect of object size on image counts and a correction for this effect were explored. The imager used in this study consisted of two PEM detector heads mounted 20 cm apart on a Lorad biopsy apparatus. The results demonstrated that a majority of the accidental coincidence events (/spl sim/80%) detected by this system were produced by radiotracer uptake in the adipose and muscle tissue of the torso. The presence of accidental coincidence events was shown to reduce lesion detectability. Much of this effect was eliminated by correction of the images utilizing estimates of accidental-coincidence contamination acquired with delayed coincidence circuitry built into the PEM system. The Compton scatter fraction for this system was /spl sim/14%. Utilization of a new scatter correction algorithm reduced the scatter fraction to /spl sim/1.5%. Finally, reduction of count recovery due to object size was measured and a correction to the data applied. Application of correction techniques

  12. Clinical value of 18F-FDG coincidence imaging for diagnosis of nasopharyngeal carcinoma

    International Nuclear Information System (INIS)

    Ning Yanli; Lou Cen; Huang Zhongke; Shi Guohua; Chen Dongfang; Mu Da

    2012-01-01

    Objective: To investigate the value of 18 F-FDG coincidence imaging for diagnosis of nasopharyngeal carcinoma. Methods: A total of 45 patients with nasopharyngeal carcinoma (33 males and 12 females, average age (55.56 ± 13.50) years), who underwent 18 F-FDG coincidence imaging before treatment, were studied retrospectively. The images of 18 F-FDG coincidence imaging (GE Millennium VG SPECT) and MRI were analyzed. The radioactivity ratio of the accumulated regions to cerebellum (T/NT)was calculated by ROI technique. The volume of nasopharyngeal carcinoma was recorded by MRI. The positive rates of 18 F-FDG coincidence imaging and EB virus-related antibody measurements were compared by paired χ 2 test. The correlation between T/NT ratios and tumor volumes were tested by Pearson correlation, and then ROC curves were established. The T/NT ratios and tumor volumes of different groups (different first symptoms, clinical stages, T stages, pathological classification and outcomes, with or without lymph node enlargement) were compared by t-test and rank sum test. Results: The positive rate of 18 F-FDG coincidence imaging was 97.78% (44/45), and the positive rate of EB virus-related antibody measurement was 95.56% (43/45, χ 2 =1.33, P>0.05). The T/NT ratio (2.439 ±1.119) and tumor volume ((7.311 ± 8.280) cm 3 ) of primary lesions had a positive correlation (r=0.463, P<0.05). The cut-off values of T/NT ratio and the tumor volume were 2.396 and 7.348 cm 3 , respectively, by ROC curves. T/NT ratios in groups with or without first symptom of epistaxis (2.847 ± 1.254 vs 2.082 ± 0.863, t=-2.409) and groups with or without facial numbness (2.855 ± 1.261 vs 2.134 ± 0.913, t=-2.225) were both significantly different (both P<0.05). T/NT ratios of differentiated and undifferentiated cancer were 2.266 ± 0.997 and 2.971 ± 1.351, respectively (t=-2.018, P<0.05). There was a significant difference of tumor volumes between groups with or without facial numbness (t=-2.684, P<0

  13. Development of a geometric uncertainty model describing the accuracy of position-sensitive, coincidence neutron detection

    Energy Technology Data Exchange (ETDEWEB)

    Trivelpiece, Cory L., E-mail: cory@psu.ed [Department of Mechanical and Nuclear Engineering, The Pennsylvania, State University, University Park, PA 16802 (United States); Brenizer, J.S. [Department of Mechanical and Nuclear Engineering, The Pennsylvania, State University, University Park, PA 16802 (United States)

    2011-01-01

    A diameter of uncertainty (D{sub u}) was derived from a geometric uncertainty model describing the error that would be introduced into position-sensitive, coincidence neutron detection measurements by charged-particle transport phenomena and experimental setup. The transport of {alpha} and Li ions, produced by the {sup 10}B(n,{alpha}) {sup 7}Li reaction, through free-standing boro-phosphosilicate glass (BPSG) films was modeled using the Monte Carlo code SRIM, and the results of these simulations were used as input to determine D{sub u} for position-sensitive, coincidence techniques. The results of these calculations showed that D{sub u} is dependent on encoder separation, the angle of charged particle emission, and film thickness. For certain emission scenarios, the magnitude of D{sub u} is larger than the physical size of the neutron converting media that were being modeled. Spheres of uncertainty were developed that describe the difference in flight path times among the bounding-case emission scenarios that were considered in this work. It was shown the overlapping spheres represent emission angles and particle flight path lengths that would be difficult to resolve in terms of particle time-of-flight measurements. However, based on the timing resolution of current nuclear instrumentation, emission events that yield large D{sub u} can be discriminated by logical arguments during spectral deconvolution.

  14. Comparison of the Savannah River Site billet active well coincidence counter and two Californium Shufflers

    International Nuclear Information System (INIS)

    Sadowski, E.T.; Griffin, J.C.; Rinard, P.M.

    1991-01-01

    A Scrap Californium Shuffler at the Savannah River Site (SRS) was calibrated to assay the U-Al cores of billets (an intermediate step in the SRS reactor fuel fabrication cycle.) The precision of the Scrap Shuffler over several years has been approximately 0.50%. A typical total uncertainty for the assay of a core on the Scrap Shuffler is approximately 0.33% for a twelve minute assay. The precision over several months and a typical total uncertainty for the Billet Active Well (neutron) Coincidence Counter (BAWCC) are approximately 1.0% and 1.9%, respectively, for a fifteen minute assay. A new Billet Californium Shuffler specifically designed for assaying SRS billets has yielded precision (over one month) and total uncertainty results of 0.40% and 0.69%, respectively, for an eight minute assay. The introduction of a measurement point into the fuel fabrication cycle to replace estimates based upon material weight will greatly enhance material and process control in the Reactor Materials area of SRS. The use of all three instruments provides a comparison of the relative merits of Active Well (neutron) Coincidence Counters (AWCCs) and shufflers for assay of homogeneous and geometrically simple material containing 235 U. The measurement precisions, systematic and random uncertainties, as well as the procurement and operation of each instrument will be compared. 3 refs., 5 figs., 1 tab

  15. Determination of the absolute activity by the coincidences 4πβ-γ method

    International Nuclear Information System (INIS)

    Urcelay Silva, A.J.

    1975-01-01

    The 4π beta-gamma coincidence method for absolute determination of activities is extremely important in the production of high-precision radioactive sources. By means of this method it is possible to obtain absolute measurements of decay to within 0.1%. Thanks to the high efficiency of the 4π counter, most of the corrections required - background, random coincidences, dead time, decay scheme and detector efficiency - are small. The paper describes the experimental set-up showing the pulses in the two branches of the system, together with the conditions under which the 4πbeta flux detector functions. To determine whether the system was functioning satisfactorily, the activity of four cobalt-60 standards (supplied by the International Bureau of Weights and Measures based at Sevres in France) was determined and the differences obtained were less than 0.5% with respect to the certificates accompanying the sources. Alterations to the flux detector are suggested so that higher accuracy may be obtained. (author)

  16. Higgs-production at LHC. Observables for the measurements of CP properties; Produktion von Higgsbosonen am LHC. Observablen zur Bestimmung ihrer CP-Quantenzahlen

    Energy Technology Data Exchange (ETDEWEB)

    Ziethe, J.

    2007-05-22

    In this work we calculated observables which can be used to determine the CP parity of the Higgs boson. We considered the neutral Higgs bosons of the MSSM as well as CP-indefinite Higgs bosons. The calculation have been made for an application at LHC. For Higgs production we considered gluon fusion (in NLO) and b-quark annihilation (in LO) and for the Higgs decay studied the decay in tau lepton or top quark. We find that the angle between the charged particles of the tau (or top) decay are a good observable to determine CP properties of the intermediate Higgs bosons. For CP indefinite Higgs bosons we considered triplet-correlation-observables. (orig.)

  17. Study and construction of a {beta}-spectrometer of uniform axial magnetic field fitted with a {beta}-{gamma} coincidence selector. Study of the {beta} spectra of {sup 32}P, {sup 203}Hg, {sup 198}Au. Measurement of the conversion coefficients of {sup 203}Ti and of {sup 198}Hg; Etude et realisation d'un spectrometre-{beta} a champ magnetique axial uniforme, muni d'un selecteur de coincidence {beta}-{gamma}. Etude des spectres {beta} du {sup 32}p, {sup 203}Hg, {sup 198}Au. Mesure des coefficients de conversion du {sup 203}Ti et du {sup 198}Hg

    Energy Technology Data Exchange (ETDEWEB)

    Parsignault, D [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1964-06-01

    In the first part is given the principle of the beta spectrometer with uniform axial field using systematically the idea of caustics. The apparatus is described and its properties compared to those deduced from trajectory calculations. The {beta}-ray and {gamma}-ray detectors and the device for selecting coincidences with a 2 {tau} resolution of 5 nanoseconds are also presented. In the second part, the spectrometer is used for studying reference elements and the most accurate results are confirmed. The {beta} spectrum of {sup 60}Co has a statistical form with an accuracy of 1 per cent; the maximum energy E{sub 0} is 316.5 {+-} 1.5 keV. That of the 7/2 + {yields} 11/2 transition for {sup 137}Cs has a unique form, once forbidden. E{sub 0}= 522 {+-} 3 keV. Conversion coefficients {alpha}{sub k} = 96 {+-} 1 X 10{sup -3} {alpha}L + M + N = 20.9 {+-} 0.5 X 10{sup -3}. The two {beta} spectra of {sup 59}Fe, separated by coincidence with the gamma, have the statistical form E{sub 0} = 462 {+-} 2 keV (55.1 + 0,3 per cent) and E{sub 1} = 275 {+-} 4 keV (44.9 {+-} 0.3 per cent). It is then verified whether the l selection rule is apparent in the shape of the phosphorus 32 beta spectrum. It is found in fact that it is not of statistical shape and its shape coefficient is determined. For a theoretical interpretation it is necessary to have better approximations than those generally used and this interpretation will not be unique. This work has also made it possible to show that the source contains a small proportion of {sup 33}P. The study of the {sup 203}Hg {beta} spectrum followed by the 279 keV gamma spectrum is designed to determine the conversion coefficients. The interior spectrum of gold 198 is not of statistical shape either. The form coefficient is determined together with the conversion coefficients which are in slight disagreement with those calculated by Rose or Sliv. An interpretation of the spectrum is put forward which proposes an imperfect compensation for the

  18. Study and construction of a {beta}-spectrometer of uniform axial magnetic field fitted with a {beta}-{gamma} coincidence selector. Study of the {beta} spectra of {sup 32}P, {sup 203}Hg, {sup 198}Au. Measurement of the conversion coefficients of {sup 203}Ti and of {sup 198}Hg; Etude et realisation d'un spectrometre-{beta} a champ magnetique axial uniforme, muni d'un selecteur de coincidence {beta}-{gamma}. Etude des spectres {beta} du {sup 32}p, {sup 203}Hg, {sup 198}Au. Mesure des coefficients de conversion du {sup 203}Ti et du {sup 198}Hg

    Energy Technology Data Exchange (ETDEWEB)

    Parsignault, D. [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1964-06-01

    In the first part is given the principle of the beta spectrometer with uniform axial field using systematically the idea of caustics. The apparatus is described and its properties compared to those deduced from trajectory calculations. The {beta}-ray and {gamma}-ray detectors and the device for selecting coincidences with a 2 {tau} resolution of 5 nanoseconds are also presented. In the second part, the spectrometer is used for studying reference elements and the most accurate results are confirmed. The {beta} spectrum of {sup 60}Co has a statistical form with an accuracy of 1 per cent; the maximum energy E{sub 0} is 316.5 {+-} 1.5 keV. That of the 7/2 + {yields} 11/2 transition for {sup 137}Cs has a unique form, once forbidden. E{sub 0}= 522 {+-} 3 keV. Conversion coefficients {alpha}{sub k} = 96 {+-} 1 X 10{sup -3} {alpha}L + M + N = 20.9 {+-} 0.5 X 10{sup -3}. The two {beta} spectra of {sup 59}Fe, separated by coincidence with the gamma, have the statistical form E{sub 0} = 462 {+-} 2 keV (55.1 + 0,3 per cent) and E{sub 1} = 275 {+-} 4 keV (44.9 {+-} 0.3 per cent). It is then verified whether the l selection rule is apparent in the shape of the phosphorus 32 beta spectrum. It is found in fact that it is not of statistical shape and its shape coefficient is determined. For a theoretical interpretation it is necessary to have better approximations than those generally used and this interpretation will not be unique. This work has also made it possible to show that the source contains a small proportion of {sup 33}P. The study of the {sup 203}Hg {beta} spectrum followed by the 279 keV gamma spectrum is designed to determine the conversion coefficients. The interior spectrum of gold 198 is not of statistical shape either. The form coefficient is determined together with the conversion coefficients which are in slight disagreement with those calculated by Rose or Sliv. An interpretation of the spectrum is put forward which proposes an imperfect compensation for the

  19. Feynman variance-to-mean in the context of passive neutron coincidence counting

    Energy Technology Data Exchange (ETDEWEB)

    Croft, S., E-mail: scroft@lanl.gov [Los Alamos National Laboratory, PO Box 1663, Los Alamos, NM 87545 (United States); Favalli, A.; Hauck, D.K.; Henzlova, D.; Santi, P.A. [Los Alamos National Laboratory, PO Box 1663, Los Alamos, NM 87545 (United States)

    2012-09-11

    Passive Neutron Coincidence Counting (PNCC) based on shift register autocorrelation time analysis of the detected neutron pulse train is an important Nondestructive Assay (NDA) method. It is used extensively in the quantification of plutonium and other spontaneously fissile materials for purposes of nuclear materials accountancy. In addition to the totals count rate, which is also referred to as the singles, gross or trigger rate, a quantity known as the reals coincidence rate, also called the pairs or doubles, is obtained from the difference between the measured neutron multiplicities in two measurement gates triggered by the incoming events on the pulse train. The reals rate is a measure of the number of time correlated pairs present on the pulse train and this can be related to the fission rates (and hence material mass) since fissions emit neutrons in bursts which are also detected in characteristic clusters. A closely related measurement objective is the determination of the reactivity of systems as they approach criticality. In this field an alternative autocorrelation signature is popular, the so called Feynman variance-to-mean technique which makes use of the multiplicity histogram formed the periodic, or clock-triggered opening of a coincidence gate. Workers in these two application areas share common challenges and improvement opportunities but are often separated by tradition, problem focus and technical language. The purpose of this paper is to recognize the close link between the Feynman variance-to-mean metric and traditional PNCC using shift register logic applied to correlated pulse trains. We, show using relationships for the late-gate (or accidentals) histogram recorded using a multiplicity shift register, how the Feynman Y-statistic, defined as the excess variance-to-mean ratio, can be expressed in terms of the singles and doubles rates familiar to the safeguards and waste assay communities. These two specialisms now have a direct bridge between

  20. Investigating the γ decay of 65Ni from particle-γ coincidence data

    Science.gov (United States)

    Campo, L. Crespo; Larsen, A. C.; Garrote, F. L. Bello; Eriksen, T. K.; Giacoppo, F.; Görgen, A.; Guttormsen, M.; Klintefjord, M.; Renstrøm, T.; Sahin, E.; Siem, S.; Tornyi, T. G.; Tveten, G. M.

    2017-07-01

    The γ decay of 65Ni has been studied from particle-γ coincidence data on the 64Ni(d ,p γ )65Ni reaction. γ -ray spectra at excitation energies below Ex≈2 MeV have been studied and compared with previous measurements. Coincidences corresponding to Ex≈4.4 -6.1 MeV have been used to constrain the shape of the nuclear level density and γ -strength function of 65Ni by means of the Oslo method. The experimental γ -strength function presents an enhancement at γ energies below Eγ≈3 MeV . In addition, a resonance-like structure centered at Eγ≈4.6 MeV is seen together with accumulated strength at Eγ≈2.6 -3.6 MeV . The obtained results contribute to the systematic study of γ decay in the Ni isotopes, which is of great interest for the understanding of both single-particle and collective nuclear structure phenomena.

  1. Development of Simultaneous Beta-and-Coincidence-Gamma Imager for Plant Imaging Research

    Energy Technology Data Exchange (ETDEWEB)

    Tai, Yuan-Chuan [Washington Univ., St. Louis, MO (United States). School of Medicine

    2016-09-30

    The goal of this project is to develop a novel imaging system that can simultaneously acquire beta and coincidence gamma images of positron sources in thin objects such as leaves of plants. This hybrid imager can be used to measure carbon assimilation in plants quantitatively and in real-time after C-11 labeled carbon-dioxide is administered. A better understanding of carbon assimilation, particularly under the increasingly elevated atmospheric CO2 level, is extremely critical for plant scientists who study food crop and biofuel production. Phase 1 of this project is focused on the technology development with 3 specific aims: (1) develop a hybrid detector that can detect beta and gamma rays simultaneously; (2) develop an imaging system that can differentiate these two types of radiation and acquire beta and coincidence gamma images in real-time; (3) develop techniques to quantify radiotracer distribution using beta and gamma images. Phase 2 of this project is to apply technologies developed in phase 1 to study plants using positron-emitting radionuclide such as 11C to study carbon assimilation in biofuel plants.

  2. A new approach to beta-gamma coincidence counting. Advance report on the Samar electronic system

    International Nuclear Information System (INIS)

    Carlos, J. E. de; Granados, C. E.

    1972-01-01

    In 4π β-γ coincidence measurements, precision on the evaluation of coincidence counting losses is made difficult because of complex overlapping effects between theβ--and γ-side dead times due to pre cursive counted events. In this context the SAMAR electronic system is aimed to give a precise way of automatic counting and reduce the need for calculated corrections. This report describes its configuration and basic features. The SAMAR has been conceived in such a manner that both beta and gamma chains are sharing a common and non extending dead-time which is simultaneously applied to both channels. The shared dead time is made to be the only one inserted throughout the chains. Overlapping effects vanish and the three counting channels have identical transmission ratios. A new dead-time circuit based on fast linear gates as blocking elements has been developed. Application of the two-oscillator Muller's method evidences a fully non-extending character. Automatism is implemented by using a live timer corrective channel controlling the counting scalers. (Author) 21 refs

  3. Evidence of sequential interatomic decay in argon trimers obtained by electron-triple-ion coincidence spectroscopy

    International Nuclear Information System (INIS)

    Liu, X-J; Saito, N; Fukuzawa, H; Morishita, Y; Stoychev, S; Kuleff, A; Suzuki, I H; Tamenori, Y; Richter, R; Pruemper, G; Ueda, K

    2007-01-01

    Sequential interatomic decay, where the first step is an Auger decay with interatomic character and the second step is a pure interatomic Coulombic decay (ICD), is identified in Ar trimers Ar 3 . The 2p hole state in Ar 3 decays via the L 2,3 M 1 M 2,3 Auger to the one-site two-hole states Ar ++ (3s -1 3p -1 )-Ar-Ar that couples to the two-site satellite states Ar + (3p -2 nl)-Ar + (3p -1 )-Ar. These states are subject to ICD to the states Ar + (3p -1 )-Ar + (3p -1 )-Ar + (3p -1 ), in which the nl electron fills the 3p hole in the same Ar site and one of the 3p electrons in the third Ar site is emitted as a slow ICD electron. This ICD process is identified unambiguously by electron-ion-ion-ion coincidence spectroscopy in which the kinetic energy of the slow ICD electron and the kinetic energy release among the three Ar + ions are measured in coincidence. (fast track communication)

  4. Performance of coincidence-based PSD on LiF/ZnS Detectors for Multiplicity Counting

    Energy Technology Data Exchange (ETDEWEB)

    Robinson, Sean M.; Stave, Sean C.; Lintereur, Azaree; Siciliano, Edward R.; Cowles, Christian C.; Kouzes, Richard T.; Behling, Richard S.

    2016-10-06

    Abstract: Mass accountancy measurement is a nuclear nonproliferation application which utilizes coincidence and multiplicity counters to verify special nuclear material declarations. With a well-designed and efficient detector system, several relevant parameters of the material can be verified simultaneously. 6LiF/ZnS scintillating sheets may be used for this purpose due to a combination of high efficiency and short die-away times in systems designed with this material, but involve choices of detector geometry and exact material composition (e.g., the addition of Ni-quenching in the material) that must be optimized for the application. Multiplicity counting for verification of declared nuclear fuel mass involves neutron detection in conditions where several neutrons arrive in a short time window, with confounding gamma rays. This paper considers coincidence-based Pulse-Shape Discrimination (PSD) techniques developed to work under conditions of high pileup, and the performance of these algorithms with different detection materials. Simulated and real data from modern LiF/ZnS scintillator systems are evaluated with these techniques and the relationship between the performance under pileup and material characteristics (e.g., neutron peak width and total light collection efficiency) are determined, to allow for an optimal choice of detector and material.

  5. Field test and evaluation of the passive neutron coincidence collar for prototype fast reactor fuel subassemblies

    International Nuclear Information System (INIS)

    Menlove, H.O.; Keddar, A.

    1982-08-01

    The passive neutron Coincidence Collar, which was developed for the verification of plutonium content in fast reactor fuel subassemblies, has been field tested using Prototype Fast Reactor fuel. For passive applications, the system measures the 240 Pu-effective mass from the spontaneous fission rate, and in addition, a self-interrogation technique is used to determine the fissile content in the subassembly. Both the passive and active modes were evaluated at the Windscale Works in the United Kingdom. The results of the tests gave a standard deviation 0.75% for the passive count and 3 to 7% for the active measurement for a 1000-s counting time. The unit will be used in the future for the verification of plutonium in fresh fuel assemblies

  6. Coincidence of asthma and bronchospasm during anesthesia in tympanomastoidectomy.

    Science.gov (United States)

    Hosseinzadeh, Nima; Samadi, Shahram; Amali, Amin; Jafari Javid, Mihan

    2014-01-01

    High prevalence of asthma and bronchospasm was observed during induction of anesthesia in patients with chronic suppurative otitis mMedia (CSOM) who underwent tympanomastoidectomy. Although several studies have proposed association of allergic diseases with CSOM but no consensus about it has been established. Current study was designed to determine the coincidence of asthma in CSOM patients. In a cross-sectional study, authors investigated medical records of 106 CSOM patients underwent tympanomastoidectomy, aged 15 to 65 years, and 95 controls, which were matched by age and sex. Participants were admitted to Valiasr Hospital, Tehran, Iran, from April of 2011 to March of 2013. Required information, such as demographic characteristics and history of allergic rhinitis (AR) and asthma were obtained from patients' medical records. The prevalence of AR in the CSOM group was higher than controls' group (19.8% and 15.8%, respectively) (P>0.05). Asthma prevalence was significantly higher in patients with CSOM (P=0.03) (OR=7.67, 95% CI:  0.9-62.5). No significant association was found between history of AR and chronic ear infections. However, asthma was significantly more common in CSOM patients. Current study indicates that asthma and risk of bronchospasm need particular attention in patients with CSOM underwent tympanomastoidectomy before and during anesthesia.

  7. Coincidence of asthma and bronchospasm during anesthesia in tympanomastoidectomy.

    Directory of Open Access Journals (Sweden)

    Nima Hosseinzadeh

    2014-12-01

    Full Text Available High prevalence of asthma and bronchospasm was observed during induction of anesthesia in patients with chronic suppurative otitis mMedia (CSOM who underwent tympanomastoidectomy. Although several studies have proposed association of allergic diseases with CSOM but no consensus about it has been established. Current study was designed to determine the coincidence of asthma in CSOM patients. In a cross-sectional study, authors investigated medical records of 106 CSOM patients underwent tympanomastoidectomy, aged 15 to 65 years, and 95 controls, which were matched by age and sex. Participants were admitted to Valiasr Hospital, Tehran, Iran, from April of 2011 to March of 2013. Required information, such as demographic characteristics and history of allergic rhinitis (AR and asthma were obtained from patients' medical records. The prevalence of AR in the CSOM group was higher than controls' group (19.8% and 15.8%, respectively (P>0.05. Asthma prevalence was significantly higher in patients with CSOM (P=0.03 (OR=7.67, 95% CI:  0.9-62.5. No significant association was found between history of AR and chronic ear infections. However, asthma was significantly more common in CSOM patients. Current study indicates that asthma and risk of bronchospasm need particular attention in patients with CSOM underwent tympanomastoidectomy before and during anesthesia.

  8. Line identification studies using traditional techniques and wavelength coincidence statistics

    International Nuclear Information System (INIS)

    Cowley, C.R.; Adelman, S.J.

    1990-01-01

    Traditional line identification techniques result in the assignment of individual lines to an atomic or ionic species. These methods may be supplemented by wavelength coincidence statistics (WCS). The strength and weakness of these methods are discussed using spectra of a number of normal and peculiar B and A stars that have been studied independently by both methods. The present results support the overall findings of some earlier studies. WCS would be most useful in a first survey, before traditional methods have been applied. WCS can quickly make a global search for all species and in this way may enable identifications of an unexpected spectrum that could easily be omitted entirely from a traditional study. This is illustrated by O I. WCS is a subject to well known weakness of any statistical technique, for example, a predictable number of spurious results are to be expected. The danger of small number statistics are illustrated. WCS is at its best relative to traditional methods in finding a line-rich atomic species that is only weakly present in a complicated stellar spectrum

  9. Energy and angle resolved studies of double photo-ionisation of helium by electron time-of-flight coincidence spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Viefhaus, J.; Avaldi, L.; Heiser, F.; Hentges, R.; Gessner, O.; Ruedel, A.; Wiedenhoeft, M.; Wieliczek, K.; Becker, U. [Fritz-Haber-Institut der Max-Planck-Gesellschaft, Berlin (Germany)

    1996-10-28

    Helium double photo-ionization is studied by a novel coincidence technique which employs time-of-flight spectrometers. Using this technique it is possible to collect simultaneously all the electron pairs, with different energy sharing, emitted by the absorption of a single energetic incident photon. The measurements, in a configuration where the two electrons emerge at 180{sup o} relative angle, provide the more complete information on the contribution of the ungerade amplitude to the triple differential cross section and allow the establishment of a relative scale for the full coincidence angular distribution measured by other experiments at the same photon energies, but only for a few selected energy-sharing conditions. (author).

  10. Revised Correlation between Odin/OSIRIS PMC Properties and Coincident TIMED/SABER Mesospheric Temperatures

    Science.gov (United States)

    Feofilov, A. G.; Petelina, S. V.; Kutepov, A. A.; Pesnell, W. D.; Goldberg, R. A.; Llewellyn, E. J.; Russell, J. M.

    2006-01-01

    The Optical Spectrograph and Infrared Imaging System (OSIRIS) instrument on board the Odin satellite detects Polar Mesospheric Clouds (PMCs) through the enhancement in the limb-scattered solar radiance. The Sounding of the Atmosphere using the Broadband Emission Radiometry (SABER) instrument on board the TIMED satellite is a limb scanning infrared radiometer that measures temperature and vertical profiles and energetic parameters for minor constituents in the mesosphere and lower thermosphere. The combination of OSIRIS and SABER data has been previously used to statistically derive thermal conditions for PMC existence [Petelina et al., 2005]. a, A.A. Kutepov, W.D. Pesnell, In this work, we employ the simultaneous common volume measurements of PMCs by OSIRIS and temperature profiles measured by SABER for the Northern Hemisphere summers of 2002-2005 and corrected in the polar region by accounting for the vibrational-vibrational energy exchange among the CO2 isotopes [Kutepov et al., 2006]. For each of 20 coincidences identified within plus or minus 1 degree latitude, plus or minus 2 degrees longitude and less than 1 hour time the frost point temperatures were calculated using the corresponding SABER temperature profile and water vapor densities of 1,3, and 10 ppmv. We found that the PMC presence and brightness correlated only with the temperature threshold that corresponds to the frost point. The absolute value of the temperature below the frost point, however, didn't play a significant role in the intensity of PMC signal for the majority of selected coincidences. The presence of several bright clouds at temperatures above the frost point is obviously related to the limitation of the limb geometry when some near- or far-field PMCs located at higher (and warmer) altitudes appear to be at lower altitudes.

  11. Correction for variable moderation and multiplication effects associated with thermal neutron coincidence counting

    International Nuclear Information System (INIS)

    Baron, N.

    1978-01-01

    A correction is described for multiplication and moderation when doing passive thermal neutron coincidence counting nondestructive assay measurements on powder samples of PuO 2 mixed arbitrarily with MgO, SiO 2 , and moderating material. The multiplication correction expression is shown to be approximately separable into the product of two independent terms; F/sub Pu/ which depends on the mass of 240 Pu, and F/sub αn/ which depends on properties of the matrix material. Necessary assumptions for separability are (1) isotopic abundances are constant, and (2) fission cross sections are independent of incident neutron energy: both of which are reasonable for the 8% 240 Pu powder samples considered here. Furthermore since all prompt fission neutrons are expected to have nearly the same energy distributions, variations among different samples can be due only to the moderating properties of the samples. Relative energy distributions are provided by a thermal neutron well counter having two concentric rings of 3 He proportional counters placed symmetrically about the well. Measured outer-to-inner ring ratios raised to an empirically determined power for coincidences, (N/sup I//N/sup O/)/sup Z/, and singles, (T/sup O//T/sup I/)/sup delta/, provide corrections for moderation and F/sub αn/ respectively, and F/sub Pu/ is approximated by M 240 /sup X//M 240 . The exponents are calibration constants determined by a least squares fitting procedure using standards' data. System calibration is greatly simplified using the separability principle. Once appropriate models are established for F/sub Pu/ and F/sub αn/, only a few standards are necessary to determine the calibration constants associated with these terms. Since F/sub Pu/ is expressed as a function of M 240 , correction for multiplication in a subsequent assay demands only a measurement of F/sub αn/

  12. Sliding bearing diagnosis with magnetic field measuring; Gleitlagerdiagnose mittels Magnetfeldmessungen

    Energy Technology Data Exchange (ETDEWEB)

    Bittner, H. [HWTS Zittau (Germany). Fachgebiet Instandhaltung/Technische Diagnostik; Kluth, T. [HWTS Zittau (Germany). Fachgebiet Instandhaltung/Technische Diagnostik

    1995-09-01

    Account of their properties sliding bearings are in high demanded and important aggregats. The destruction of a bearing will be almost followed by the destruction of the aggregate. Various methods are existing for sliding bearing diagnosis. This methods often not permit the condition recognition. A new electromagnetical method will be developed. This method permits the condition recognition during working time of the aggregate. It also permits the recognition of wear. The method bases on a measuring of leak current over measuring the generated magnetic fields with Rogowski-coils. (orig.) [Deutsch] Gleitlager befinden sich wegen ihrer Eigenschaften in hoch beanspruchten und exponierten Aggregaten. Die Zerstoerung eines Gleitlagers fuehrt meist auch zur Zerstoerung des gefuehrten Aggregats. Zur Gleitlagerdiagnose existiert eine Reihe Verfahren. Ihnen wird ein elektromagnetisches Verfahren gegenuebergestellt. Damit koennen Gleitlagerzustaende waehrend des Aggregatebetriebs identifiziert werden. Das Verfahren erlaubt gleichermassen die Bestimmung des Lagerverschleisses. Es basiert auf der Ableitstrommessung, bei der sich ausbildende Magnetfelder durch Rogowskispulen ausgemessen werden. (orig.)

  13. Improving the singles rate method for modeling accidental coincidences in high-resolution PET

    International Nuclear Information System (INIS)

    Oliver, Josep F; Rafecas, Magdalena

    2010-01-01

    Random coincidences ('randoms') are one of the main sources of image degradation in PET imaging. In order to correct for this effect, an accurate method to estimate the contribution of random events is necessary. This aspect becomes especially relevant for high-resolution PET scanners where the highest image quality is sought and accurate quantitative analysis is undertaken. One common approach to estimate randoms is the so-called singles rate method (SR) widely used because of its good statistical properties. SR is based on the measurement of the singles rate in each detector element. However, recent studies suggest that SR systematically overestimates the correct random rate. This overestimation can be particularly marked for low energy thresholds, below 250 keV used in some applications and could entail a significant image degradation. In this work, we investigate the performance of SR as a function of the activity, geometry of the source and energy acceptance window used. We also investigate the performance of an alternative method, which we call 'singles trues' (ST) that improves SR by properly modeling the presence of true coincidences in the sample. Nevertheless, in any real data acquisition the knowledge of which singles are members of a true coincidence is lost. Therefore, we propose an iterative method, STi, that provides an estimation based on ST but which only requires the knowledge of measurable quantities: prompts and singles. Due to inter-crystal scatter, for wide energy windows ST only partially corrects SR overestimations. While SR deviations are in the range 86-300% (depending on the source geometry), the ST deviations are systematically smaller and contained in the range 4-60%. STi fails to reproduce the ST results, although for not too high activities the deviation with respect to ST is only a few percent. For conventional energy windows, i.e. those without inter-crystal scatter, the ST method corrects the SR overestimations, and deviations from

  14. It takes two—coincidence coding within the dual olfactory pathway of the honeybee

    OpenAIRE

    Brill, Martin F.; Meyer, Anneke; Rössler, Wolfgang

    2015-01-01

    To rapidly process biologically relevant stimuli, sensory systems have developed a broad variety of coding mechanisms like parallel processing and coincidence detection. Parallel processing (e.g., in the visual system), increases both computational capacity and processing speed by simultaneously coding different aspects of the same stimulus. Coincidence detection is an efficient way to integrate information from different sources. Coincidence has been shown to promote associative learning and...

  15. Differential coincidence circuit in the 10-10 second region (1960)

    International Nuclear Information System (INIS)

    Van Zurk, R.; Grenoble-1 Univ., 38; Commissariat a l'Energie Atomique, Saclay

    1960-01-01

    A coincidence circuit of low resolution time using the differential coincidence Bay principle is described. It uses three 6BN6 tubes ordered to chronotron structure. Results with Radiotechnique 56 AVP photomultipliers and for 60 Co γ-γ coincidences are 4,6.10 -10 s (full width at half maximum) if the efficiency is ε = 40 per cent and also 7,2.10 -10 s if ε = 85 per cent. (author) [fr

  16. Design and performance of the Savannah River Site Billet Active Well Coincidence Counter

    International Nuclear Information System (INIS)

    Griffin, J.C.; Sadowski, E.T.

    1991-01-01

    The Savannah River Site (SRS) has acquired, installed, and tested a custom-built Billet Active Well (neutron) Coincidence Counter (BAWCC). The BAWCC is used to make accountability measurements of the 235 U content of U-Al coextrusion billets in the SRS fuel fabrication facility. The instrument design incorporates a unique center-source configuration, with two moderated americium-lithium (AmLi) neutron sources located in a central spindle that inserts through the center hole of the U-Al billets. This configuration, a result of earlier experimental studies at SRS, yields improved response and precision for billet assay when compared to the standard AWCC source arrangement. Initial tests of the BAWCC at SRS have yielded one-sigma uncertainties of 0.8--1.0% for a fifteen-minute assay. This paper will describe the design, testing program and performance characteristics of the BAWCC

  17. A coincidence-type ion-electron converter detector for low-energy protons

    International Nuclear Information System (INIS)

    Benka, O.; Weinzierl, P.; Dobrozemsky, R.; Stratowa, C.

    1981-04-01

    A coincidence type ion-electron converter detector has been developed and used - together with an electrostatic energy-analyser - for precision measurements of the energy distribution of recoil protons from free-neutron decay. The most important aspect of the development was, besides keeping the background below 0,2 counts/sec in the presence of a certain radiation background, to achieve a high and energy-independent counting probability for protons with energies between 100 and 1000 eV. With an acceleration voltage of about 25 kV and Al-foils (20 to 35 ug/cmsup2) as converter, we obtained counting efficiences of 70 to 85 percent. The design and performance of the detector system, employing six foils with different sensitive areas, are described and discussed in detail. (author)

  18. PLUMEX II: A second set of coincident radar and rocket observations of equatorial spread-F

    International Nuclear Information System (INIS)

    Szuszczewicz, E.P.; Tsunoda, R.T.; Narcisi, R.; Holmes, J.C.

    1981-01-01

    PLUMEX II, the second rocket in a two-rocket operation that successfully executed coincident rocket and radar measurements of backscatter plumes and plasma depletions, was launched into the mid-phase of well-developed equatorial spread-F. In contrast with the first operation, the PLUMEX II results show large scale F-region irregularities only on the bottomside gradient with smaller scale irregularities (i.e., small scale structure imbedded in larger scale features) less intense than corresponding observations in PLUMEX I. The latter result could support current interpretations of east-west plume asymmetry which suggests that during initial upwelling the western wall of a plume (the PLUMEX I case) is more unstable than its eastern counterpart (the PLUMEX II case). In addition, ion mass spectrometer results are found to provide further support for an ion transport model which ''captures'' bottomside ions in an upwelling bubble and transports them to high altitudes

  19. True coincidence summing corrections for an extended energy range HPGe detector

    Energy Technology Data Exchange (ETDEWEB)

    Venegas-Argumedo, Y. [Centro de Investigación en Materiales Avanzados (CIMAV), Miguel de Cervantes 120, Chihuahua, Chih 31109 (Mexico); M.S. Student at CIMAV (Mexico); Montero-Cabrera, M. E., E-mail: elena.montero@cimav.edu.mx [Centro de Investigación en Materiales Avanzados (CIMAV), Miguel de Cervantes 120, Chihuahua, Chih 31109 (Mexico)

    2015-07-23

    True coincidence summing (TCS) effect for natural radioactive families of U-238 and Th-232 represents a problem when an environmental sample with a close source-detector geometry measurement is performed. By using a certified multi-nuclide standard source to calibrate an energy extended range (XtRa) HPGe detector, it is possible to obtain an intensity spectrum slightly affected by the TCS effect with energies from 46 to 1836 keV. In this work, the equations and some other considerations required to calculate the TCS correction factor for isotopes of natural radioactive chains are described. It is projected a validation of the calibration, performed with the IAEA-CU-2006-03 samples (soil and water)

  20. Characterizations of double pulsing in neutron multiplicity and coincidence counting systems

    Energy Technology Data Exchange (ETDEWEB)

    Koehler, Katrina E., E-mail: kkoehler@lanl.gov [Los Alamos National Laboratory, P. O. Box 1663, Los Alamos, NM 87545 (United States); Henzl, Vladimir [Los Alamos National Laboratory, P. O. Box 1663, Los Alamos, NM 87545 (United States); Croft, Stephen S. [Oak Ridge National Laboratory, 1 Bethel Valley Rd, Oak Ridge, TN 37831 (United States); Henzlova, Daniela; Santi, Peter A. [Los Alamos National Laboratory, P. O. Box 1663, Los Alamos, NM 87545 (United States)

    2016-10-01

    Passive neutron coincidence/multiplicity counters are subject to non-ideal behavior, such as double pulsing and dead time. It has been shown in the past that double-pulsing exhibits a distinct signature in a Rossi-alpha distribution, which is not readily noticed using traditional Multiplicity Shift Register analysis. However, it has been assumed that the use of a pre-delay in shift register analysis removes any effects of double pulsing. In this work, we use high-fidelity simulations accompanied by experimental measurements to study the effects of double pulsing on multiplicity rates. By exploiting the information from the double pulsing signature peak observable in the Rossi-alpha distribution, the double pulsing fraction can be determined. Algebraic correction factors for the multiplicity rates in terms of the double pulsing fraction have been developed. We discuss the role of these corrections across a range of scenarios.

  1. Obesidade e asma: associação ou coincidência? Obesity and asthma: association or coincidence?

    Directory of Open Access Journals (Sweden)

    Daniella Fernandes Camilo

    2010-02-01

    Full Text Available OBJETIVO: A asma e a obesidade estão entre as maiores causas de morbidade na infância e adolescência. A obesidade precoce aumenta as chances de doenças crônicas degenerativas no adulto. Embora a concomitância de ambas as situações clínicas vem sendo demonstrada em vários estudos, os mecanismos intrínsecos dessa associação ainda são pouco conhecidos. Portanto, o objetivo deste artigo foi revisar os principais trabalhos sobre a associação de obesidade e asma e verificar se existe relação de causa e efeito entre ambas. FONTES DOS DADOS: Revisão sistemática baseada em bases de dados indexadas MEDLINE (PubMed e SciELO. Foram revisados artigos originais (transversal, caso-controle e prospectivo e meta-análises publicados no período de janeiro de 1998 a janeiro de 2008. Foram pesquisados estudos divulgados em língua inglesa, espanhola e portuguesa. SÍNTESE DOS DADOS: Embora existam muitos estudos sobre as crescentes prevalências da asma e da obesidade, poucos estabelecem relações de causa e efeito entre ambas. Os mecanismos fisiopatológicos e os fatores envolvidos nesse processo ainda são pouco conhecidos. CONCLUSÃO: O rigor metodológico em estudos futuros deverá buscar respostas para melhor entender se existe associação entre asma e obesidade, ou se a relação entre ambas as doenças é coincidência.OBJECTIVE: Asthma and obesity are among the major causes of morbidity in childhood and adolescence. Early obesity increases the chances of chronic degenerative diseases in adults. Although the concomitance or both clinical situations are being demonstrated in various studies, the intrinsic mechanisms of this association are still very little known. Therefore, the objective of this article was to review the main studies on the association of obesity and asthma and check if there is a cause-effect relation between them. SOURCES: Systematic review based on indexed data bases MEDLINE (PubMed and SciELO. Original articles

  2. Raman non-coincidence effect of boroxol ring: The interplay between repulsion and attraction forces in the glassy, supercooled and liquid state

    Science.gov (United States)

    Kalampounias, Angelos G.; Papatheodorou, George N.

    2018-06-01

    Temperature dependent Raman spectra of boric oxide have been measured in a temperature range covering the glassy, supercooled and liquid state. The shift of the isotropic band assigned to boroxol rings relative to the anisotropic component upon heating the glass is measured and attributed to the Raman non-coincidence effect. The measured shift is associated with the competition between attraction and repulsion forces with increasing temperature. The relation of dephasing and orientational relaxation times to the non-coincidence effect of the condensed phases has been examined. We discuss our results in the framework of the current phenomenological status of the field in an attempt to separate the attraction and repulsion contributions corresponding to the observed non-coincidence effect.

  3. Suitability study of using a coincidence monitor for room air radioactivity monitoring in a PET center

    International Nuclear Information System (INIS)

    Roellig, D.; Reichelt, C.; Iwatschenko-Borho, M.

    2001-01-01

    The application of radioactive nuclides in medicine may cause as well radioactive exposure of personnel (Medical Technical Assistants). In the present case the exposure of personnel in the area of medical positron-emission tomography (PET) within the Research Center of Rossendorf due to exhalation of the injected activity by the patient shall be investigated. For this purpose it is necessary to measure the activity concentration of the room air. Conventional methods such as collecting samples on special filters are not suitable due to the short half-life time of the used nuclides. Standard type continuous monitors are hardly suitable as well, because the injected activity of the patient and various radioactive sources required for the calibration of the PET-Camera produce an increased gamma background. In order to eliminate these disturbing influences a monitor has been constructed which uses CCM (cobalt coincidence method) developed by the company Thermo Eberline ESM. This method is specially suitable because upon each radioactive decay of PET nuclides positrons are emitted which in turn annihilate via the simultaneous emission of two 511 keV gamma quanta under an angle of 180 . The air to be measured is sucked through a cavity with two scintillation detectors on opposite sides. The coincident pulses produced by annihilating positrons inside the cavity are counted by a suitable electronic. Gamma quanta from outside the cavity can produce a pulse only in one detector and are rejected. Therefore no heavy lead shielding is required. Besides the mechanical construction of the monitor optimization and calibration for different PET-nuclides had to be performed. Special attention was paid to the sampling system. The air intake had to be close to the breathing zone of the MTA. The hose to the monitor had to be as short as possible. The target of the work was to design a model for an industrial monitor. (orig.) [de

  4. Standardization of {sup 67}Ga, {sup 51}Cr and {sup 55}Fe by live-timed anti-coincidence counting with extending dead time

    Energy Technology Data Exchange (ETDEWEB)

    Silva, Carlos J. da [Laboratorio Nacional de Metrologia das Radiacoes Ionizantes (LNMRI), Instituto de Radioprotecao e Dosimetria (IRD), Comissao Nacional de Energia Nuclear - CNEN, Av. Salvador Allende, s/n0-Recreio, CEP 22780-160 Rio de Janeiro (Brazil) and Laboratorio de Instrumentacao Nuclear (LIN/PEN/COPPE/UFRJ), Caixa Postal 68590, CEP 21945-970 Rio de Janeiro (Brazil)], E-mail: Carlos@ird.gov.br; Iwahara, A.; Poledna, R.; Bernardes, E.M. de O; Prinzio, M.A.R.R. de [Laboratorio Nacional de Metrologia das Radiacoes Ionizantes (LNMRI), Instituto de Radioprotecao e Dosimetria (IRD), Comissao Nacional de Energia Nuclear - CNEN, Av. Salvador Allende, s/n0-Recreio, CEP 22780-160 Rio de Janeiro (Brazil); Lopes, Ricardo T. [Laboratorio de Instrumentacao Nuclear (LIN/PEN/COPPE/UFRJ), Caixa Postal 68590, CEP 21945-970 Rio de Janeiro (Brazil)

    2008-02-15

    In this work, the activity standardization of {sup 51}Cr, {sup 55}Fe and {sup 67}Ga by live-timed anti-coincidence counting with extending dead time is described. The difficulties of the method, the uncertainties of the results of the measurements and the comparison of these results with others measurement methods are discussed.

  5. Standardization of I-125 solution by extrapolation of an efficiency wave obtained by coincidence X-(X-γ) counting method

    International Nuclear Information System (INIS)

    Iwahara, A.

    1989-01-01

    The activity concentration of 125 I was determined by X-(X-α) coincidence counting method and efficiency extrapolation curve. The measurement system consists of 2 thin NaI(T1) scintillation detectors which are horizontally movable on a track. The efficiency curve is obtained by symmetricaly changing the distance between the source and the detectors and the activity is determined by applying a linear efficiency extrapolation curve. All sum-coincidence events are included between 10 and 100 KeV window counting and the main source of uncertainty is coming from poor counting statistic around zero efficiency. The consistence of results with other methods shows that this technique can be applied to photon cascade emitters and are not discriminating by the detectors. It has been also determined the 35,5 KeV gamma-ray emission probability of 125 I by using a Gamma-X type high purity germanium detector. (author) [pt

  6. The influence of radiation and light on Ps formation in PMMA and PE studied by coincidence Doppler-broadening spectroscopy

    CERN Document Server

    Suzuki, T; Shantarovich, V; Kondo, K; Hamada, E; Matso, M; Ma Li; Ito, Y

    2003-01-01

    Using two Ge detectors, the high-resolution Doppler-broadening energy spectra of positron annihilation gamma rays has been obtained by measuring the coincidences of the two photons. Light bleaching and oxygen effects on positron annihilation were investigated in this way. A large enhancement of the high-momentum part of the coincidence Doppler spectra was observed in poly(methylmethacrylate) (PMMA), which contains oxygen atoms in the polymer structure. Bleaching experiments in PMMA and in copolymer ethylene-methylmethacrylate EMMA (LDPE+MMA 3 mol%) have demonstrated that the enhancement effect may be due to the trapping of positrons by the polar -C sup + 6-O sup - groups, followed by positron annihilation with the electrons belonging to oxygen.

  7. Dissociation and ionization of molecular ions by ultra-short intense laser pulses probed by coincidence 3D momentum imaging

    International Nuclear Information System (INIS)

    Ben-Itzhak, Itzik; Wang, Pengqian; Xia, Jiangfan; Max Sayler, A.; Smith, Mark A.; Maseberg, J.W.; Carnes, Kevin D.; Esry, Brett D.

    2005-01-01

    We have experimentally explored laser-induced dissociation and ionization of diatomic molecular ions using coincidence 3D momentum imaging. The vibrationally excited molecular ion beam (4-8 keV) is crossed by an ultrafast intense laser beam (28-200 fs, 10 13 -10 14 W/cm 2 ). The resulting fragments are recorded in coincidence by a time and position-sensitive detector. Complete angular distributions and kinetic energy release maps are reconstructed from the measured dissociation-momentum vectors. The angular distribution of the H + + H fragments was found to be strongly correlated to their kinetic energy release upon dissociation. Low KER was associated with very narrow angular distributions and high KER with distributions peaking away from the laser polarization. Ionization was found to be smaller than dissociation and increased with laser intensity. The H + + H + fragments have a very narrow angular distribution along the laser polarization

  8. An Optimized Design of Single-Channel Beta-Gamma Coincidence Phoswich Detector by Geant4 Monte Carlo Simulations

    Directory of Open Access Journals (Sweden)

    Weihua Zhang

    2011-01-01

    Full Text Available An optimized single-channel phoswich well detector design has been proposed and assessed in order to improve beta-gamma coincidence measurement sensitivity of xenon radioisotopes. This newly designed phoswich well detector consists of a plastic beta counting cell (BC404 embedded in a CsI(Tl crystal coupled to a photomultiplier tube. The BC404 is configured in a cylindrical pipe shape to minimise light collection deterioration. The CsI(Tl crystal consists of a rectangular part and a semicylindrical scintillation part as a light reflector to increase light gathering. Compared with a PhosWatch detector, the final optimized detector geometry showed 15% improvement in the energy resolution of a 131mXe 129.4 keV conversion electron peak. The predicted beta-gamma coincidence efficiencies of xenon radioisotopes have also been improved accordingly.

  9. Using anisotropies in prompt fission neutron coincidences to assess the neutron multiplication of highly multiplying subcritical plutonium assemblies

    Energy Technology Data Exchange (ETDEWEB)

    Mueller, J.M., E-mail: jonathan_mueller@ncsu.edu; Mattingly, J.

    2016-07-21

    There is a significant and well-known anisotropy between the prompt neutrons emitted from a single fission event; these neutrons are most likely to be observed at angles near 0° or 180° relative to each other. However, the propagation of this anisotropy through different generations of a fission chain reaction has not been previously studied. We have measured this anisotropy in neutron–neutron coincidences from a subcritical highly-multiplying assembly of plutonium metal. The assembly was a 4.5 kg α-phase plutonium metal sphere composed of 94% {sup 239}Pu and 6% {sup 240}Pu by mass. Data were collected using two EJ-309 liquid scintillators and two EJ-299 plastic scintillators. The angular distribution of neutron–neutron coincidences was measured at 90° and 180° and found to be largely isotropic. Simulations were performed using MCNPX-PoliMi of similar plutonium metal spheres of varying sizes and a correlation between the neutron multiplication of the assembly and the anisotropy of neutron–neutron coincidences was observed. In principle, this correlation could be used to assess the neutron multiplication of an unknown assembly.

  10. Interaction of multicharged ions with molecules (CO{sub 2}, C{sub 60}) by coincident electron spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Moretto-Capelle, P.; Bordenave-Montesquieu, D.; Bordenave-Montesquieu, A. [Universite Paul Sabatier, Toulouse (France). Lab. CAR-IRSAMC

    2001-07-01

    First results for the investigation of electron capture processes in collisions between multicharged ions and molecule targets using electron spectroscopy in coincidence with charged fragments, are presented. It is shown that a much more detailed investigation of the capture reaction can be achieved using molecular instead of heavy atomic targets provided that an analysis of the target dissociation is made. The collisional systems {sup 18}O{sup 8+}+Ar, CO{sub 2} and C{sub 60} have been studied at 80 keV. Non coincident electron spectra as well as first results of double or triple coincidence experiments are discussed. Kinetic energy distributions of the C{sub n}{sup +} fragments (n=1 to 8) produced in multiple capture processes from C{sub 60} target are given. A detailed investigation of the double capture process with CO{sub 2} molecule allows the measurement of kinetic energy release distributions (KERD) which characterize the dissociation of CO{sub 2}{sup 2+} molecular ions; our results are found to be very similar to those measured in double photoionisation experiments. (orig.)

  11. Improvements of low-level radioxenon detection sensitivity by a state-of-the art coincidence setup.

    Science.gov (United States)

    Cagniant, A; Le Petit, G; Gross, P; Douysset, G; Richard-Bressand, H; Fontaine, J-P

    2014-05-01

    The ability to quantify isotopic ratios of 135, 133 m, 133 and 131 m radioxenon is essential for the verification of the Comprehensive Nuclear-Test Ban Treaty (CTBT). In order to improve detection limits, CEA has developed a new on-site setup using photon/electron coincidence (Le Petit et al., 2013. J. Radioanal. Nucl. Chem., DOI : 10.1007/s 10697-013-2525-8.). Alternatively, the electron detection cell equipped with large silicon chips (PIPS) can be used with HPGe detector for laboratory analysis purpose. This setup allows the measurement of β/γ coincidences for the detection of (133)Xe and (135)Xe; and K-shell Conversion Electrons (K-CE)/X-ray coincidences for the detection of (131m)Xe, (133m)Xe and (133)Xe as well. Good energy resolution of 11 keV at 130 keV and low energy threshold of 29 keV for the electron detection were obtained. This provides direct discrimination between K-CE from (133)Xe, (133m)Xe and (131m)Xe. Estimation of Minimum Detectable Activity (MDA) for (131m)Xe is in the order of 1mBq over a 4 day measurement. An analysis of an environmental radioxenon sample using this method is shown. © 2013 The Authors. Published by Elsevier Ltd All rights reserved.

  12. Health effects of measures and technologies of the energy transition. The views expressed in this paper need not necessarily coincide with those of the Environment Agency; Gesundheitliche Auswirkungen von Massnahmen und Technologien der Energiewende. Die in diesem Beitrag geaeusserten Ansichten muessen nicht notwendigerweise mit denen des Umweltbundesamtes uebereinstimmen

    Energy Technology Data Exchange (ETDEWEB)

    Plass, Dietrich [Umweltbundesamt, Berlin (Germany). Fachrichtung: Expositionsschaetzung, gesundheitsbezogene Indikatoren; Conrad, Andre

    2017-06-01

    A sustainable supply of future generations with energy is not possible on the basis of fossil and nuclear energy sources. With the measures and technologies used, energy transition offers the opportunity to gradually reduce the use of these energy sources and to convert the energy supply system to the use of renewable energies. This chapter has shown that the departure from the existing system can contribute to a significant improvement in the health of the population. However, it is important parallel to the nationwide implementation of measures and technologies of the energy transition to ensure a continuous monitoring of possible health effects in order to be able to respond to potential risks at an early stage and to take adequate measures to reduce them. [German] Eine nachhaltige Versorgung zukuenftiger Generationen mit Energie ist auf Basis fossiler und nuklearer Energiequellen nicht moeglich. Die Energiewende bietet mit den eingesetzten Massnahmen und Technologien die Moeglichkeit, die Nutzung dieser Energiequellen sukzessiv abzubauen und das Energieversorgungssystem auf die Verwendung erneuerbarer Energien umzustellen. Das vorliegende Kapitel hat aufgezeigt, dass die Abkehr vom bestehenden System zu einer deutlichen Verbesserung der Bevoelkerungsgesundheit beitragen kann. Es ist jedoch wichtig, bei der flaechendeckenden Einfuehrung von Massnahmen und Technologien der Energiewende eine kontinuierliche Beobachtung moeglicher Effekte auf die Gesundheit sicherzustellen, um fruehzeitig auf potenzielle Risiken reagieren zu koennen und adaequate Massnahmen zu ihrer Reduktion zu ergreifen.

  13. Alpha particle spectra in coincidence with normal and superdeformed states in {sup 150}Tb

    Energy Technology Data Exchange (ETDEWEB)

    Viesti, G.; Lunardon, M.; Bazzacco, D. [dell`Universita, Padova (Italy)]|[INFN, Padova (Italy)] [and others

    1996-12-31

    The study of correlations between particle evaporation from highly excited compound nuclei at large angular momenta and the states in the final evaporation residues (ER) is a field of investigation which has been opened, in the last years, with the advent of the new large {gamma}-ray arrays. It is now possible to correlate the evaporation spectra to various bands with shapes ranging from spherical to superdeformed (SD) in the same final nucleus. It is generally accepted that the particle evaporation from the compound nucleus is chaotic and that only in the near-yrast {gamma} cascade, where the feeding of different classes of states takes place, the ordered motion is restored. The sensitivity of the particle spectra on the feeding of specific states in the residual nuclei can be taken as an indication that additional degrees of freedom might be important in the evaporation process or that particular regions of the phase space open to the decay populate preferentially some selected structures in the final cold nucleus. This latter point is important for the understanding of the feeding mechanism of SD states. Several experiments performed so far did not find a clear dependence of the shapes of the particle spectra on the excited states having different deformations in the ER. For example, the proton spectra in coincidence with transitions in the SD bands of {sup 133}Nd and {sup 152}Dy nuclei were found to be similar to those in coincidence with transitions in the normal deformed (ND) bands. Alpha particles have been proposed since long as a sensitive probe of the deformation of the emitting nucleus. Results are presented here of an experiment in which the authors have measured the energy spectra of alpha particles associated with different classes of states (ND and SD) in the {sup 150}Tb nucleus populated in the reaction {sup 37}Cl({sup 120}Sn, {alpha}3n{gamma}){sup 150}Tb.

  14. The IFIN-HH triple coincidence liquid scintillation counter

    CSIR Research Space (South Africa)

    Razdolescu, AC

    2006-10-01

    Full Text Available at IFIN-HH using a 3 H standard. The performances of the IFIN-HH TDCR counter was checked against the measurement results of the TDCR counters of CSIR NML (South Africa), RC (Poland) and LNHB (France). A set of ready-to-measure Ni-63 sources in liquid...

  15. New technique for determination of long-lived radioisotopes, Iodine-129, using multiparameter coincidence spectrometry

    International Nuclear Information System (INIS)

    Hatsukawa, Yuichi; Oshima, Masumi; Toh, Yosuke; Shinohara, Nobuo; Kushita, Kosuke; Ueno, Takashi

    2003-01-01

    Multiparameter coincidence γ-ray spectrometry based on g-g coincidence is widely used in the field of nuclear structure studies, and has produced many successful results. In this study, feasibility of the method for neutron activation analysis of long lived iodine isotope, 129 I, was investigated. (author)

  16. Coincidence and noncoincidence counting (81Rb and 43K): a comparative study

    International Nuclear Information System (INIS)

    Ikeda, S.; Duken, H.; Tillmanns, H.; Bing, R.J.

    1975-01-01

    The accuracy of imaging and resolution obtained with 81 Rb and 43 K using coincidence and noncoincidence counting was compared. Phantoms and isolated infarcted dog hearts were used. The results clearly show the superiority of coincidence counting with a resolution of 0.5 cm. Noncoincidence counting failed to reveal even sizable defects in the radioactive source. (U.S.)

  17. A new apparatus for electron-ion multiple coincidence momentum imaging spectroscopy

    International Nuclear Information System (INIS)

    Morishita, Y.; Kato, M.; Pruemper, G.; Liu, X.-J.; Lischke, T.; Ueda, K.; Tamenori, Y.; Oura, M.; Yamaoka, H.; Suzuki, I.H.; Saito, N.

    2006-01-01

    We have developed a new experimental apparatus for the electron-ion multiple coincidence momentum imaging spectroscopy in order to obtain the angular distributions of vibration-resolved photoelectrons from molecules fixed in space. The apparatus consists of a four-stage molecular supersonic jet and a spectrometer analyzing three-dimensional momenta of fragment ions and electrons in coincidence

  18. Differential coincidence circuit in the 10{sup -10} second region (1960); Circuit de coincidence differentiel dans le domaine de 10{sup -10} seconde (1960)

    Energy Technology Data Exchange (ETDEWEB)

    Van Zurk, R [Commissariat a l' Energie Atomique, Lab. de Physique Nucleaire, Grenoble (France).Centre d' Etudes Nucleaires; [Grenoble-1 Univ., 38 (France); [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1960-07-01

    A coincidence circuit of low resolution time using the differential coincidence Bay principle is described. It uses three 6BN6 tubes ordered to chronotron structure. Results with Radiotechnique 56 AVP photomultipliers and for {sup 60}Co {gamma}-{gamma} coincidences are 4,6.10{sup -10} s (full width at half maximum) if the efficiency is {epsilon} = 40 per cent and also 7,2.10{sup -10} s if {epsilon} = 85 per cent. (author) [French] Un circuit de coincidence differentiel du type de Bay, utilise en selecteur en temps a canal mobile, a ete construit pour la mesure des periodes {gamma} et des periodes d'annihilation du positon dans differents materiaux. Il comporte trois tubes 6BN6 disposes en structure chronotron. On a utilise les nouveaux photomultiplicateurs 56 AVP avec scintillateur plastique. Avec les coincidences {gamma}-{gamma} du {sup 60}Co, on obtient 2T 4,6.10{sup -10} s avec une efficacite de 40 pour cent et 2T = 7,2.10{sup -10} s avec une efficacite de 85 pour cent. (auteur)

  19. Studies on the decay of 160Tb to levels in 160Dy by Ge (Li)-Ge(Li)-coincidence system

    International Nuclear Information System (INIS)

    Hassan, A.M.; Abou-Zeid, M.A.; Mekamer, M.

    1981-01-01

    This work concerned with the study of the energy levels and the properties of gamma-ray transitions in 160 Dy resulting from the B-decay of the parent radioactive isotope 160 Tb (72 d.). These studies have been done by means of, single and gamma-gamma coincidence measurements. Log(ft). Internal Conversion Coefficient (ICC) values and the branching ratios have been calculated. The construction and testes of the Ge(Li)-Ge(Li) gamma-gamma coincidence spectrometer are presented. In addition to the previously reported transitions in three new transitions of energies 203, 420 and 1048 keV have been observed for the first time. The energy level at 1288.60 keV is confirmed, due to the presence of the 246 keV and 1005 keV gamma-ray transitions in the singles and gamma-gamma coincidence spectra. Furthermore the B-intensity feeding this level was calculated for the first time to be 0.08%. The log(ft) values of the energy level at 1288.6 keV was calculated for the first time to be 10.79. The energy level diagram of 160 Dy as summerised in the present work consists of 12 excited states, the levels at 581(6 + ) and 1391 keV reported by some authors were not encluded, since no transitions populated or depopulated these levels could be observed

  20. A Rapid Coordinate Transformation Method Applied in Industrial Robot Calibration Based on Characteristic Line Coincidence

    Science.gov (United States)

    Liu, Bailing; Zhang, Fumin; Qu, Xinghua; Shi, Xiaojia

    2016-01-01

    Coordinate transformation plays an indispensable role in industrial measurements, including photogrammetry, geodesy, laser 3-D measurement and robotics. The widely applied methods of coordinate transformation are generally based on solving the equations of point clouds. Despite the high accuracy, this might result in no solution due to the use of ill conditioned matrices. In this paper, a novel coordinate transformation method is proposed, not based on the equation solution but based on the geometric transformation. We construct characteristic lines to represent the coordinate systems. According to the space geometry relation, the characteristic line scan is made to coincide by a series of rotations and translations. The transformation matrix can be obtained using matrix transformation theory. Experiments are designed to compare the proposed method with other methods. The results show that the proposed method has the same high accuracy, but the operation is more convenient and flexible. A multi-sensor combined measurement system is also presented to improve the position accuracy of a robot with the calibration of the robot kinematic parameters. Experimental verification shows that the position accuracy of robot manipulator is improved by 45.8% with the proposed method and robot calibration. PMID:26901203

  1. Unbiased estimators of coincidence and correlation in non-analogous Monte Carlo particle transport

    International Nuclear Information System (INIS)

    Szieberth, M.; Kloosterman, J.L.

    2014-01-01

    Highlights: • The history splitting method was developed for non-Boltzmann Monte Carlo estimators. • The method allows variance reduction for pulse-height and higher moment estimators. • It works in highly multiplicative problems but Russian roulette has to be replaced. • Estimation of higher moments allows the simulation of neutron noise measurements. • Biased sampling of fission helps the effective simulation of neutron noise methods. - Abstract: The conventional non-analogous Monte Carlo methods are optimized to preserve the mean value of the distributions. Therefore, they are not suited to non-Boltzmann problems such as the estimation of coincidences or correlations. This paper presents a general method called history splitting for the non-analogous estimation of such quantities. The basic principle of the method is that a non-analogous particle history can be interpreted as a collection of analogous histories with different weights according to the probability of their realization. Calculations with a simple Monte Carlo program for a pulse-height-type estimator prove that the method is feasible and provides unbiased estimation. Different variance reduction techniques have been tried with the method and Russian roulette turned out to be ineffective in high multiplicity systems. An alternative history control method is applied instead. Simulation results of an auto-correlation (Rossi-α) measurement show that even the reconstruction of the higher moments is possible with the history splitting method, which makes the simulation of neutron noise measurements feasible

  2. A Rapid Coordinate Transformation Method Applied in Industrial Robot Calibration Based on Characteristic Line Coincidence

    Directory of Open Access Journals (Sweden)

    Bailing Liu

    2016-02-01

    Full Text Available Coordinate transformation plays an indispensable role in industrial measurements, including photogrammetry, geodesy, laser 3-D measurement and robotics. The widely applied methods of coordinate transformation are generally based on solving the equations of point clouds. Despite the high accuracy, this might result in no solution due to the use of ill conditioned matrices. In this paper, a novel coordinate transformation method is proposed, not based on the equation solution but based on the geometric transformation. We construct characteristic lines to represent the coordinate systems. According to the space geometry relation, the characteristic line scan is made to coincide by a series of rotations and translations. The transformation matrix can be obtained using matrix transformation theory. Experiments are designed to compare the proposed method with other methods. The results show that the proposed method has the same high accuracy, but the operation is more convenient and flexible. A multi-sensor combined measurement system is also presented to improve the position accuracy of a robot with the calibration of the robot kinematic parameters. Experimental verification shows that the position accuracy of robot manipulator is improved by 45.8% with the proposed method and robot calibration.

  3. Testing gravitational parity violation with coincident gravitational waves and short gamma-ray bursts

    International Nuclear Information System (INIS)

    Yunes, Nicolas; O'Shaughnessy, Richard; Owen, Benjamin J.; Alexander, Stephon

    2010-01-01

    Gravitational parity violation is a possibility motivated by particle physics, string theory, and loop quantum gravity. One effect of it is amplitude birefringence of gravitational waves, whereby left and right circularly polarized waves propagate at the same speed but with different amplitude evolution. Here we propose a test of this effect through coincident observations of gravitational waves and short gamma-ray bursts from binary mergers involving neutron stars. Such gravitational waves are highly left or right circularly polarized due to the geometry of the merger. Using localization information from the gamma-ray burst, ground-based gravitational wave detectors can measure the distance to the source with reasonable accuracy. An electromagnetic determination of the redshift from an afterglow or host galaxy yields an independent measure of this distance. Gravitational parity violation would manifest itself as a discrepancy between these two distance measurements. We exemplify such a test by considering one specific effective theory that leads to such gravitational parity violation, Chern-Simons gravity. We show that the advanced LIGO-Virgo network and all-sky gamma-ray telescopes can be sensitive to the propagating sector of Chern-Simons gravitational parity violation to a level roughly 2 orders of magnitude better than current stationary constraints from the LAGEOS satellites.

  4. Visual verification of linac light and radiation fields coincidence

    International Nuclear Information System (INIS)

    Monti, Angelo F.; Frigerio, Milena; Frigerio, Giovanna

    2003-01-01

    X-ray and light field alignment evaluation is carried out during linac quality assurance programs. In this paper, we compare the size of the light field measured by a photodiode and by a more traditional visual observation with the size of the x-ray field. The comparison between actual light field size, measured with the photodiode, and light field size measured by human eye allow us to verify the reliability of human eye in the evaluation of this parameter. The visual field is always larger than real light field; however, it agrees better with the x-ray field. It matches the light field if we take into account the 25% (± 1%) of the decrement line of the maximum central lightening; however, this method simulates better the actual field employed in radiation treatments

  5. Fast-slow coincidence systems with very high time resolution

    International Nuclear Information System (INIS)

    Naday, I.; Kajcsos, Zs.; Kozma, Gy.; Kanyo, M.

    1981-02-01

    The measuring of very short times has recently become increasingly important. In this paper the authors describe their studies on the various parts of a timing system in an attempt to improve its parameters. The detector system, i.e. the transit time differences of the photomultipliers, the construction of the divider network, the various types of timing discriminators, the time-to-pulse height converters and the gating system were investigated. Two types of constant fraction discriminators are introduced: one for general timing applications, the other placed inside the detector head for positron lifetime measurements. (author)

  6. Multitracer studies for determining seepage water and anion movement in four types of soil using lysimeters with different functions and designs; Multitracer-Untersuchungen zur Bestimmung der Sickerwasser- und Anionenbewegung in vier Bodenformen bei Lysimetern unterschiedlicher Nutzung und Bauart

    Energy Technology Data Exchange (ETDEWEB)

    Knappe, S.; Russow, R. [UFZ - Umweltforschungszentrum Leipzig-Halle GmbH, Bad Lauchstaedt (Germany). Sektion Bodenforschung; Seeger, J. [Lysimeterstation Falkenberg (Germany)

    1999-02-01

    Lysimeter experiments based on the stable isotope tracer technique are a suitable means of examining the complex relationships governing water and material transport processes in the soil. The present paper reports on experiments in which water and nitrate movement was traced directly by means of lysimeters placed at different depths and using deuterium water and [{sup 15}N]N-nitrate for pulse marking. Extensive investigations carried out during the dissection of soil monoliths that had been used for many years in lysimeters offered an opportunity for stable isotope tracer studies aimed at determining seepage water and anion movement in undisturbed soils and, after dismantling the lysimeters, conducting soil analyses to find out more about the fate of nonpercolated tracers at various soil depths. Following other authors, bromide anions were additionally used as conservative tracers. [Deutsch] Zur Untersuchung der komplexen Zusammenhaenge des Wasser- und Stofftransportes im Boden bieten sich Lysimeterversuche unter Nutzung der stabilisotopen Tracertechnik an. In der vorliegenden Arbeit wird zunaechst ueber die direkte Verfolgung der Wasser- und Nitrat-Bewegung in tiefengestaffelten Lysimetern durch Pulsmarkierung mit Deuteriumwasser und [{sup 15}N]Nitrat berichtet. Im Rahmen von umfangreichen Untersuchungen bei der Zerlegung von langjaehrig in Lysimetern genutzten Bodenmonolithen bestand des weiteren die Moeglichkeit, stabilisotope Traceruntersuchungen zur Bestimmung der Sickerwasser- und Anionenbewegung an ungestoerten Boeden durchzufuehren und nach der Zerlegung der Lysimeter ueber entsprechende Analysen des Bodens Aussagen zum Verbleib der nicht perkolierten Tracer in verschiedenen Bodentiefen zu treffen. Zusaetzlich wurde dabei das von anderen Autoren bereits genutzte Bromid-Anion als sogenannter konservativer Tracer eingesetzt. (orig.)

  7. Background elimination methods for multidimensional coincidence γ-ray spectra

    International Nuclear Information System (INIS)

    Morhac, M.

    1997-01-01

    In the paper new methods to separate useful information from background in one, two, three and multidimensional spectra (histograms) measured in large multidetector γ-ray arrays are derived. The sensitive nonlinear peak clipping algorithm is the basis of the methods for estimation of the background in multidimensional spectra. The derived procedures are simple and therefore have a very low cost in terms of computing time. (orig.)

  8. Intrinsic coincident linear polarimetry using stacked organic photovoltaics.

    Science.gov (United States)

    Roy, S Gupta; Awartani, O M; Sen, P; O'Connor, B T; Kudenov, M W

    2016-06-27

    Polarimetry has widespread applications within atmospheric sensing, telecommunications, biomedical imaging, and target detection. Several existing methods of imaging polarimetry trade off the sensor's spatial resolution for polarimetric resolution, and often have some form of spatial registration error. To mitigate these issues, we have developed a system using oriented polymer-based organic photovoltaics (OPVs) that can preferentially absorb linearly polarized light. Additionally, the OPV cells can be made semitransparent, enabling multiple detectors to be cascaded along the same optical axis. Since each device performs a partial polarization measurement of the same incident beam, high temporal resolution is maintained with the potential for inherent spatial registration. In this paper, a Mueller matrix model of the stacked OPV design is provided. Based on this model, a calibration technique is developed and presented. This calibration technique and model are validated with experimental data, taken with a cascaded three cell OPV Stokes polarimeter, capable of measuring incident linear polarization states. Our results indicate polarization measurement error of 1.2% RMS and an average absolute radiometric accuracy of 2.2% for the demonstrated polarimeter.

  9. Testing the Cosmic Coincidence Problem and the Nature of Dark Energy

    International Nuclear Information System (INIS)

    Dalal, Neal; Abazajian, Kevork; Jenkins, Elizabeth; Manohar, Aneesh V.

    2001-01-01

    Dark energy models which alter the relative scaling behavior of dark energy and matter could provide a natural solution to the cosmic coincidence problem -- why the densities of dark energy and dark matter are comparable today. A generalized class of dark energy models is introduced which allows noncanonical scaling of the ratio of dark matter and dark energy with the Robertson-Walker scale factor a(t) . We show that determining whether there is a coincidence problem, and the extent of cosmic coincidence, can be addressed by several forthcoming experiments

  10. Spectral lines and coincidence tables for the determination of zirconium, niobium and tantalum with the ICP

    International Nuclear Information System (INIS)

    Wuensch, G.; Wennemer, A.

    1987-01-01

    Coincidence tables for ICP-AES are given for 20 Zr lines, 9 Nb lines and 7 Ta lines. They include 582 interferent lines of 49 elements. The specified interference data (IEC and CCR) hold for a bandwidth FWHM = 16 pm and an interferent concentration of 1,000 mg/l. For trace determinations of Zr, Nb, Ta in a matrix of Fe, Z, Zr, Nb, Ta the dependence of the interference on the matrix concentration is specified up to 10,000 mg/l. Interference data CCR calculated for the ICP from the NBS tables often differ from the measured data by several orders of magnitude. The spectrum of Zr measured at a high concentration shows many weak lines most of which are not even listed in the MIT tables. They give rise to a quasi-continuous background the intensity of which increases nearly linearly with the matrix concentration. Therefore, an increase of sample concentration will not lead to an improved detection limit. The line intensities found in our investigations match well with those listed in the Wohlers tables. (orig.)

  11. Estimation of coincidence and correlation in non-analogous Monte Carlo particle transport - 159

    International Nuclear Information System (INIS)

    Szieberth, M.; Leen Kloosterman, J.

    2010-01-01

    The conventional non-analogous Monte Carlo methods are optimized to preserve the mean value of the distributions and therefore they are not suited for non-Boltzmann problems like the estimation of coincidences or correlations. This paper presents a general method called history splitting for the non-analogous estimation of such quantities. The basic principle of the method is that a non-analogous particle history can be interpreted as a collection of analogous histories with different weights according to the probability of their realization. Calculations with a simple Monte Carlo program for a pulse-height-type estimator prove that the method is feasible and provides unbiased estimation. Different variance reduction techniques have been tried with the method and Russian roulette turned out to be ineffective in high multiplicity systems. An alternative history control method is applied instead. Simulation results of a Feynman-α measurement shows that even the reconstruction of the higher moments is possible with the history splitting method, which makes the simulation of neutron noise measurements feasible. (authors)

  12. Intrinsic coincident full-Stokes polarimeter using stacked organic photovoltaics and architectural comparison of polarimeter techniques

    Science.gov (United States)

    Yang, Ruonan; Sen, Pratik; O'Connor, B. T.; Kudenov, M. W.

    2017-08-01

    An intrinsic coincident full-Stokes polarimeter is demonstrated by using stain-aligned polymer-based organic photovoltaics (OPVs) which can preferentially absorb certain polarized states of incident light. The photovoltaic-based polarimeter is capable of measuring four stokes parameters by cascading four semitransparent OPVs in series along the same optical axis. Two wave plates were incorporated into the system to modulate the S3 stokes parameter so as to reduce the condition number of the measurement matrix. The model for the full-Stokes polarimeter was established and validated, demonstrating an average RMS error of 0.84%. The optimization, based on minimizing the condition number of the 4-cell OPV design, showed that a condition number of 2.4 is possible. Performance of this in-line polarimeter concept was compared to other polarimeter architectures, including Division of Time (DoT), Division of Amplitude (DoAm), Division of Focal Plane (DoFP), and Division of Aperture (DoA) from signal-to-noise ratio (SNR) perspective. This in-line polarimeter concept has the potential to enable both high temporal (as compared with a DoT polarimeter) and high spatial resolution (as compared with DoFP and DoA polarimeters). We conclude that the intrinsic design has the same √2 SNR advantage as the DoAm polarimeter, but with greater compactness.

  13. Spectroscopy of {sup 189,187}Pb from gamma-FMA coincidences

    Energy Technology Data Exchange (ETDEWEB)

    Janssens, R.V.F.; Davids, C.N.; Blumenthal, D. [and others

    1995-08-01

    The very neutron-deficient Pb isotopes are of much current interest because they exhibit shape coexistence between a spherical groundstate and a deformed prolate excited configuration located very low in excitation energy. Last year the nucleus {sup 186}Pb was studied at the FMA in an FMA-{gamma}-{gamma} coincidence experiment. The purpose of the present measurement was to delineate, for the first time, the groundstate and near groundstate excitations in the odd Pb isotopes {sup 189,187}Pb in order to identify the orbitals which have an important role in driving the nuclear shape. The experiment was performed only very recently at the FMA with 10 Compton-suppressed Ge detectors from the Argonne Notre Dame BGO Gamma-Ray facility. {sup 187}Pb was studied with the {sup 155}Gd({sup 36}Ar,4n) reaction at 179 MeV, while {sup 189}Pb was reached with the {sup 158}Gd({sup 36}Ar,5n) reaction at the same beam energy. The analysis just began. It can already be stated that transitions in both Pb isotopes were identified and that it should be possible to establish level schemes. The presence of possible isomeric states in {sup 189}Pb will be checked in a follow-up experiment planned in Canberra. A similar measurement on {sup 187}Pb appears very difficult because of the very small cross section involved.

  14. Radioisotope studies of the farmville meteorite using γγ-coincidence spectrometry.

    Science.gov (United States)

    Howard, Chris; Ferm, Megan; Cesaratto, John; Daigle, Stephen; Iliadis, Christian

    2014-12-01

    Radionuclides are cosmogenically produced in meteorites before they fall to the surface of the Earth. Measurement of the radioactive decay of such nuclides provides a wealth of information on the irradiation conditions of the meteorite fragment, the intensity of cosmic rays in the inner solar system, and the magnetic activity of the Sun. We report here on the detection of (26)Al using a sophisticated spectrometer consisting of a HPGe detector and a NaI(Tl) annulus. It is shown that modern γ-ray spectrometers represent an interesting alternative to other detection techniques. Data are obtained for a fragment of the Farmville meteorite and compared to results from Geant4 simulations. In particular, we report on optimizing the detection sensitivity by using suitable coincidence gates for deposited energy and event multiplicity. We measured an (26)Al activity of 48.5±3.5dpm/kg for the Farmville meteorite, in agreement with previously reported values for other H chondrites. Copyright © 2014 Elsevier Ltd. All rights reserved.

  15. Position coincidence optical identifications using Texas interferometer radio positions

    International Nuclear Information System (INIS)

    Bozyan, E.P.

    1979-01-01

    1048 radio source positions measured with the Texas Interferometer were searched for optical identifications on glass copies of the Palomar Sky Survey E and O plates, resulting in 242 identifications and 806 blank fields. Finding charts are presented for 124 of the 125 new identifications not previously reported in the literature, and for 73 blank fields containing nearby optical objects which may be real identifications. This brings the cumulative number of Texas radio positions searched to 2015, producing 864 optical identifications and 1151 blank fields

  16. Chemical analysis using coincidence Doppler broadening and supporting first-principles theory: Applications to vacancy defects in compound semiconductors

    International Nuclear Information System (INIS)

    Makkonen, I.; Rauch, C.; Mäki, J.-M.; Tuomisto, F.

    2012-01-01

    The Doppler broadening of the positron annihilation radiation contains information on the chemical environment of vacancy defects trapping positrons in solids. The measured signal can, for instance, reveal impurity atoms situated next to vacancies. As compared to integrated quantities such as the positron annihilation rate or the annihilation line shape parameters, the full Doppler spectrum measured in the coincidence mode contains much more useful information for defect identification. This information, however, is indirect and complementary understanding is needed to fully interpret the results. First-principles calculations are a valuable tool in the analysis of measured spectra. One can construct an atomic-scale model for a given candidate defect, calculate from first principles the corresponding Doppler spectrum, and directly compare results between experiment and theory. In this paper we discuss recent examples of successful combinations of coincidence Doppler broadening measurements and supporting first-principles calculations. These demonstrate the predictive power of state-of-the-art calculations and the usefulness of such an approach in the chemical analysis of vacancy defects.

  17. Real-Time, Fast Neutron Coincidence Assay of Plutonium With a 4-Channel Multiplexed Analyzer and Organic Scintillators

    Science.gov (United States)

    Joyce, Malcolm J.; Gamage, Kelum A. A.; Aspinall, M. D.; Cave, F. D.; Lavietes, A.

    2014-06-01

    The design, principle of operation and the results of measurements made with a four-channel organic scintillator system are described. The system comprises four detectors and a multiplexed analyzer for the real-time parallel processing of fast neutron events. The function of the real-time, digital multiple-channel pulse-shape discrimination analyzer is described together with the results of laboratory-based measurements with 252Cf, 241Am-Li and plutonium. The analyzer is based on a single-board solution with integrated high-voltage supplies and graphical user interface. It has been developed to meet the requirements of nuclear materials assay of relevance to safeguards and security. Data are presented for the real-time coincidence assay of plutonium in terms of doubles count rate versus mass. This includes an assessment of the limiting mass uncertainty for coincidence assay based on a 100 s measurement period and samples in the range 0-50 g. Measurements of count rate versus order of multiplicity for 252Cf and 241Am-Li and combinations of both are also presented.

  18. Comparison of satellite reflectance algorithms for estimating chlorophyll-a in a temperate reservoir using coincident hyperspectral aircraft imagery and dense coincident surface observations

    Science.gov (United States)

    We analyzed 10 established and 4 new satellite reflectance algorithms for estimating chlorophyll-a (Chl-a) in a temperate reservoir in southwest Ohio using coincident hyperspectral aircraft imagery and dense water truth collected within one hour of image acquisition to develop si...

  19. The resolving limit of a three-diode coincidence circuit; Limite de resolution d'un circuit de coincidence a trois diodes; Predel razreshayushchej sposobnosti trekhdiodnoj skhemy sovpadeniya; Poder de resolucion de un circuito de coincidencia de tres diodos

    Energy Technology Data Exchange (ETDEWEB)

    De Vries, H [University of Marburg, Marburg, Federal Republic of Germany (Germany)

    1962-04-15

    To investigate the resolving limit of a three-diode coincidence circuit according to De Benedetti and Richings, a complete coincidence device, consisting of diode stage, amplifier, amplitude discriminator, and Univibrator was tested with pulses of 10{sup -9} s risetime and 2 x 10{sup -9} s basal duration. The amplitudes were measured and also the integrals of the pulses received at the amplifier output as well as the resolution curve dependent on the interesting parameters-amplitude of the input pulses, input resistance of the amplifier, operating conditions of the diodes, etc. In order to explain the measurements certain investigations were made. The resolution curve of the coincidence device was deduced and the resolving time calculated. It was calculated how the diode stage, the amplifier noise and the matching of the amplifier to the diode stage determine the resolving time of the coincidence device. An analysis of the measurements and theoretical results yielded 10{sup -11} s as the lowest resolving time-limit which can be realized with a three-diode coincidence device under optimum conditions. The derivation of the resolution curve is given and the measurements are reported. It is shown that experimental and theoretical results are in good agreement. (author) [French] Pour etudier la limite de resolution d'un circuit de coincidence a trois diodes, selon la methode de De Benedetti et Richings, l'auteur a essaye un systeme a coincidences complet comportant un ensemble de diodes, un amplificateur, un selecteur d'amplitude et un univibrateur, pour des impulsions d'un temps de montee de 10{sup -9} s et d'une duree de base de 2 x 10{sup -9} s. Il a mesure les amplitudes et les integrales des impulsions recues a la sortie de l'amplificateur ainsi que la courbe de resolution en fonction des parametres interessants (amplitude des impulsions d'entree, resistance d'entree de l'amplificateur, regime de fonctionnement des diodes, etc.). L'auteur a cherche a expliquer les

  20. A coincidence method for the simultaneous measurement of the photoionization of several masses

    International Nuclear Information System (INIS)

    Broeker, G.

    1989-11-01

    This study was made in the working team Ding (Hahn-Meitner Institute Berlin) in the framework of photoionization experiments on Van-der-Waals clusters. The experiments were performed at the Berlin electron storage ring (BESSY). In a molecular-beam source clusters are produced and ionized by monochromatic light. The mass of the ions arising hereby is determined with a time-of-flight mass spectrometer. Within this thesis a method and an electronic device was developed, by which it is made possible to gather simultaneously the wave-length dependence of several masses. (orig.) With 27 refs [de

  1. A position sensitive parallel plate avalanche fission detector for use in particle induced fission coincidence measurements

    NARCIS (Netherlands)

    Plicht, J. van der

    1980-01-01

    A parallel plate avalanche detector developed for the detection of fission fragments in particle induced fission reactions is described. The active area is 6 × 10 cm2; it is position sensitive in one dimension with a resolution of 2.5 mm. The detector can withstand a count rate of 25000 fission

  2. Scattering recoil coincidence spectrometry: a new experimental technique for profiling hydrogen isotopes in LOW-Z thin films

    International Nuclear Information System (INIS)

    Forster, J.S.; Leslie, J.R.; Laursen, T.

    1990-01-01

    The new technique for profiling light elements in thin, self-supporting foils, which uses a coincidence measurement over very large solid angles, has been demonstrated experimentally. A beam of 2.0 MeV 4 He particles was used to bombard films of (i) cracked ethylene and (ii) evaporated carbon which was subsequently implanted with 7.5 keV 1 H + ions to a concentration of 10 17 /cm 2 . Plots of E α vs E p clearly show the 1 H distributions in the foil. (author)

  3. High proportion of smaller ranged hummingbird species coincides with ecological specialization across the Americas

    DEFF Research Database (Denmark)

    Sonne, Jesper; Martín González, Ana M.; Maruyama, Pietro K.

    2016-01-01

    Ecological communities that experience stable climate conditions have been speculated to preserve more specialized interspecific associations and have higher proportions of smaller ranged species (SRS). Thus, areas with disproportionally large numbers of SRS are expected to coincide geographicall...

  4. On the extension of (e,2e) theory to coincidence studies of ion-atom collisions

    International Nuclear Information System (INIS)

    Godunov, A.L.; Kampp, Marco; Sulik, B.; Walters, H.R.J.; Whelan, Colm T.

    2007-01-01

    The extension of (e,2e) theory to the coincidence studies of ion-atom collisions is considered. The simultaneous ionization of projectile and target is discussed and results are presented for transfer ionization

  5. Angular correlations of coincident electron-positron pairs in heavy ion collisions

    International Nuclear Information System (INIS)

    Graf, O.

    1988-10-01

    In the present thesis angular correlations of coincident electron-positron pairsnin heavy ion collisions are studied. It is meant as a contribution to the answer of fundamental questions in the quantum electrodynamics of strong fields. (orig./HSI) [de

  6. A data acquisition system for coincidence imaging using a conventional dual head gamma camera

    Science.gov (United States)

    Lewellen, T. K.; Miyaoka, R. S.; Jansen, F.; Kaplan, M. S.

    1997-06-01

    A low cost data acquisition system (DAS) was developed to acquire coincidence data from an unmodified General Electric Maxxus dual head scintillation camera. A high impedance pick-off circuit provides position and energy signals to the DAS without interfering with normal camera operation. The signals are pulse-clipped to reduce pileup effects. Coincidence is determined with fast timing signals derived from constant fraction discriminators. A charge-integrating FERA 16 channel ADC feeds position and energy data to two CAMAC FERA memories operated as ping-pong buffers. A Macintosh PowerPC running Labview controls the system and reads the CAMAC memories. A CAMAC 12-channel scaler records singles and coincidence rate data. The system dead-time is approximately 10% at a coincidence rate of 4.0 kHz.

  7. A data acquisition system for coincidence imaging using a conventional dual head gamma camera

    International Nuclear Information System (INIS)

    Lewellen, T.K.; Miyaoka, R.S.; Kaplan, M.S.

    1996-01-01

    A low cost data acquisition system (DAS) was developed to acquire coincidence data from an unmodified General Electric Maxxus dual head scintillation camera. A high impedance pick-off circuit provides position and energy signals to the DAS without interfering with normal camera operation. The signals are pulse-clipped to reduce pileup effects. Coincidence is determined with fast timing signals derived from constant fraction discriminators. A charge-integrating FERA 16 channel ADC feeds position and energy data to two CAMAC FERA memories operated as ping-pong buffers. A Macintosh PowerPC running Labview controls the system and reads the CAMAC memories. A CAMAC 12-channel scaler records singles and coincidence rate data. The system dead-time is approximately 10% at a coincidence rate of 4.0 kHz

  8. Measurements with high spectral resolution of backscattered radiation over clouds in the spectral range {Delta}{lambda} = 0.2 - 4.5 {mu}m. Final report; Spektral hochaufloesende Messungen rueckgestreuter Strahlung ueb Wolken im Spektralbereich {Delta}{lambda} = 0.2 - 4.5 {mu}m. Endbericht

    Energy Technology Data Exchange (ETDEWEB)

    Grassl, H [World Meteorological Organization (WMO), Geneva (Switzerland); Fischer, J [Freie Univ. Berlin (Germany). Inst. fuer Weltraumwissenschaften; Bakan, S [Max-Planck-Institut fuer Meteorologie, Hamburg (Germany); Armbruster, W [Freie Univ. Berlin (Germany). Inst. fuer Weltraumwissenschaften; Bartsch, B [Max-Planck-Institut fuer Meteorologie, Hamburg (Germany); Betancor, M [Hamburg Univ. (Germany). Meteorologisches Inst.; Kollewe, M [Hamburg Univ. (Germany). Meteorologisches Inst.; Schueller, L [Freie Univ. Berlin (Germany). Inst. fuer Weltraumwissenschaften

    1996-12-31

    The following five problems were to be investigated: 1. Explanation of the discrepancies between measured and calculated data for the absorption of solar radiation by clouds. 2. Verification and application of remote measuring methods for determining cloud height and optical density, droplet size distribution and liquid water concentrations within clouds, and cloud phases. 3. Derivation and verification of a remote measuring method for determining the total atmospheric vapour concentration. 4. Remote measuring of aerosol type and optical density. 5. Remote measurement of the total concentration of atmospheric trace gases (O{sub 3}, CO, SO{sub 2}, NO{sub 2}). (orig./KW) [Deutsch] Es sollten fuenf Teilziele untersucht werden: 1. Erklaerung der Diskrepanzen bei der Absorption der Sonnenstrahlung in Wolken, die im Vergleich von Messung und Strahlungstransportrechnung auftreten. 2. Verifizierung und Anwendung von Fernerkundungsverfahren zur Bestimmung von: - Wolkenhoehe und optischer Dicke der Wolken - Troepfchengroessenverteilung und Fluessigwassergehalt von Wolken - Wolkenphase. 3. Herleitung und Verifizierung eines Fernerkundungsverfahrens zur Bestimmung des Gesamtwasserdampfgehalts der Atmosphaere. 4. Fernerkundung von Aerosoltyp und optischer Dicke der Aerosole. 5. Fernerkundung des Gesamtgehalts atmosphaerischer Spurengase (O{sub 3}, CO, SO{sub 2} und NO{sub 2}). (orig./KW)

  9. Coincidence and covariance data acquisition in photoelectron and -ion spectroscopy. I. Formal theory

    Science.gov (United States)

    Mikosch, Jochen; Patchkovskii, Serguei

    2013-10-01

    We derive a formal theory of noisy Poisson processes with multiple outcomes. We obtain simple, compact expressions for the probability distribution function of arbitrarily complex composite events and its moments. We illustrate the utility of the theory by analyzing properties of coincidence and covariance photoelectron-photoion detection involving single-ionization events. The results and techniques introduced in this work are directly applicable to more general coincidence and covariance experiments, including multiple ionization and multiple-ion fragmentation pathways.

  10. Multidimensional coincidence point results for generalized $(\\psi ,\\theta ,\\varphi$-contraction on ordered metric spaces

    Directory of Open Access Journals (Sweden)

    Bhavana Deshpande

    2017-11-01

    Full Text Available The main objective of this research article is to establish some coincidence point theorem for $g$-non-decreasing mappings under generalized $(\\psi ,\\theta ,\\varphi $-contraction on a partially ordered metric space. Furthermore, we show how multidimensional results can be seen as a simple consequences of our unidimensional coincidence point theorem. Our results modify, improve, sharpen, enrich and generalize various known results.

  11. Subtraction of random coincidences in γ-ray spectroscopy: A new approach

    International Nuclear Information System (INIS)

    Pattabiraman, N.S.; Ghugre, S.S.; Basu, S.K.; Garg, U.; Ray, S.; Sinha, A.K.; Zhu, S.

    2006-01-01

    A new analytical method for estimation and subsequent subtraction of random coincidences has been developed. It utilizes the knowledge of the counts in the main diagonal of a background-subtracted symmetric data set for the estimation of the events originating from random coincidences. This procedure has been successfully applied to several data sets. It could be a valuable tool for low-fold data sets, especially for low-cross-section events

  12. The Absolute Standardization Method of 18F by Using 4π(PC)-γ Coincidence Counting System

    International Nuclear Information System (INIS)

    Pujadi

    2003-01-01

    The absolute standardization of 18 F radionuclide had been carried out using 4π(PC)-γ coincidence counting. The radionuclide 18 F fluoro 2 deoxyglucose (FDG) was the quantity used at nuclear medicine in diagnosis of oncology. The radionuclide 18 F had been produced by 18 O(p,n) 18 F reaction in a cyclotron. Source preparation had been done by gravimetry method after source was dissolved in aquadest. The samples have been measured using 4π(PC)-γ coincidence counting on different three window gamma energy, the gamma windows were set on 511 keV peak, 1022 keV and above 511 keV region. The result of measurement on 1022 keV peak and above 511 keV region, are fairly good with discrepancy about 0.15%, but the linearity of gamma window above 511 keV is the best with R 2 = 0.8287. The measurement on 511 keV gamma window region gave the result with difference 2.28% compared with another two region. (author)

  13. Coincidence (e,e'p) Scattering on 40Ar and 48Ti to Aid Precision Neutrino Oscillation Experiments

    Science.gov (United States)

    Abrams, Dan; E12-14-012 Collaboration

    2017-09-01

    Neutrino oscillations are an active area of research, with experiments such as DUNE (Deep Underground Neutrino Experiment). DUNE will make use of large liquid argon detectors to perform a precision measurement of the CP violating phase. Hence, an understanding of the argon nuclear ground state and its response to (anti-)neutrino interactions is of paramount importance. Information about the nuclear ground state is encapsulated in the spectral function, S (k , E) , the joint probability of removing a nucleon of momentum k = |k | from the ground state leaving the residual (A-1) system with excitation energy E. E12-14-012 at Jefferson Lab ran in early 2017 and has measured the argon spectral function through coincidence (e ,e' p) scattering on 40Ar and 48Ti. The results of E12-14-012 are important to both the neutrino and nuclear physics communities. A direct measurement of the coincidence (e ,e' p) cross section from 40Ar and 48Ti will provide valuable information about the argon nucleus, as well as the experimental input necessary to constrain theoretical models used to calculate S (k , E) , paving the way for reliable estimates of the neutrino cross sections. Data from E12-14-012 is currently being analyzed at UVA and Va. Tech. Supported in part by the Department of Energy Grant No: DE-FG02-96ER40950.

  14. The ancient Egyptian civilization: maximum and minimum in coincidence with solar activity

    Science.gov (United States)

    Shaltout, M.

    It is proved from the last 22 years observations of the total solar irradiance (TSI) from space by artificial satellites, that TSI shows negative correlation with the solar activity (sunspots, flares, and 10.7cm Radio emissions) from day to day, but shows positive correlations with the same activity from year to year (on the base of the annual average for each of them). Also, the solar constant, which estimated fromth ground stations for beam solar radiations observations during the 20 century indicate coincidence with the phases of the 11- year cycles. It is known from sunspot observations (250 years) , and from C14 analysis, that there are another long-term cycles for the solar activity larger than 11-year cycle. The variability of the total solar irradiance affecting on the climate, and the Nile flooding, where there is a periodicities in the Nile flooding similar to that of solar activity, from the analysis of about 1300 years of the Nile level observations atth Cairo. The secular variations of the Nile levels, regularly measured from the 7 toth 15 century A.D., clearly correlate with the solar variations, which suggests evidence for solar influence on the climatic changes in the East African tropics The civilization of the ancient Egyptian was highly correlated with the Nile flooding , where the river Nile was and still yet, the source of the life in the Valley and Delta inside high dry desert area. The study depends on long -time historical data for Carbon 14 (more than five thousands years), and chronical scanning for all the elements of the ancient Egyptian civilization starting from the firs t dynasty to the twenty six dynasty. The result shows coincidence between the ancient Egyptian civilization and solar activity. For example, the period of pyramids building, which is one of the Brilliant periods, is corresponding to maximum solar activity, where the periods of occupation of Egypt by Foreign Peoples corresponding to minimum solar activity. The decline

  15. A Web-based Google-Earth Coincident Imaging Tool for Satellite Calibration and Validation

    Science.gov (United States)

    Killough, B. D.; Chander, G.; Gowda, S.

    2009-12-01

    The Group on Earth Observations (GEO) is coordinating international efforts to build a Global Earth Observation System of Systems (GEOSS) to meet the needs of its nine “Societal Benefit Areas”, of which the most demanding, in terms of accuracy, is climate. To accomplish this vision, satellite on-orbit and ground-based data calibration and validation (Cal/Val) of Earth observation measurements are critical to our scientific understanding of the Earth system. Existing tools supporting space mission Cal/Val are often developed for specific campaigns or events with little desire for broad application. This paper describes a web-based Google-Earth based tool for the calculation of coincident satellite observations with the intention to support a diverse international group of satellite missions to improve data continuity, interoperability and data fusion. The Committee on Earth Observing Satellites (CEOS), which includes 28 space agencies and 20 other national and international organizations, are currently operating and planning over 240 Earth observation satellites in the next 15 years. The technology described here will better enable the use of multiple sensors to promote increased coordination toward a GEOSS. The CEOS Systems Engineering Office (SEO) and the Working Group on Calibration and Validation (WGCV) support the development of the CEOS Visualization Environment (COVE) tool to enhance international coordination of data exchange, mission planning and Cal/Val events. The objective is to develop a simple and intuitive application tool that leverages the capabilities of Google-Earth web to display satellite sensor coverage areas and for the identification of coincident scene locations along with dynamic menus for flexibility and content display. Key features and capabilities include user-defined evaluation periods (start and end dates) and regions of interest (rectangular areas) and multi-user collaboration. Users can select two or more CEOS missions from a

  16. Development of a coincidence system for radio-nuclide standardization using surface barrier detectors

    International Nuclear Information System (INIS)

    Koskinas, M.F.

    1988-01-01

    A system for the standardization of alpha-gamma or electron-X radionuclide emitters has been developed in the present work. The system consists of one or two surface barrier detectors for alpha or electron detection which are coupled to thin-window NaI (T1) crystals suitable for low energy X or gamma ray detection. The performance of the system has been verified by means of the standardization of 241 Am, 137 Cs and 109 Cd solutions. The activity has been obtained using the extrapolation method applied to the 4Πα-γ and 2Πe c -X coincidence technique. The surface barrier detection efficiency was varied by placing absorbers over the radioactive sources or by changing the source to detector distance. The results were compared to those obtained using conventional absolute systems based on gas-flow and pressurized 4Π proportional counters, or using radioactive solutions standardized in international comparisons spondored by the Bureau International des Poids et Mesures. The expect and measured activities agree within the experimental uncertainties which were: 0.2 % for 241 Am, 0.7% for 137 Cs and 0.6% for 109 Cd. The ratio between the probabilities of (electron capture + internal conversion) and internal conversion for the K-shell of 109 Cd has been determined. The result is: 2.8883 ± 0.016. (author) [pt

  17. Coincidence of the alpine-nival ecotone with the summer snowline

    International Nuclear Information System (INIS)

    Gottfried, M; Toechterle, R; Grabherr, G; Hantel, M; Maurer, C; Pauli, H

    2011-01-01

    The alpine-nival ecotone is the transition between the lower located alpine grassland/tundra zone and the upper located sparsely vegetated nival zone in the mountains. Its characteristics are qualitatively known. Here we study the dynamics of the ecotone through a quantitative approach based on plant data (from Mt Schrankogel, 3497 m, observations 1994 and 2004) and snow data (from 268 routine climate stations in the Alps, observations 1975-2004). We introduce the nivality index as the area ratio of nival and alpine plants, and the snow duration as the length of the summer snow cover. We fit a nonlinear probabilistic model to our field data; it yields state functions of both quantities. The nivality index curve comprises the entire information of the plant data in one analytical function; the snow duration curve represents the equivalent for the full snow data set. Thus all relevant parameters of both quantities follow from the respective state function. We find that the analytical profile of the alpine-nival ecotone at Mt Schrankogel (based on nivality index observations from the altitude interval 2910-3090 m) happens to sit right in the center of the independently determined summer snow profile across the entire Alps; specifically, the central altitude of the Schrankogel ecotone coincides almost perfectly with the central altitude of Alpine snow duration. Both state functions show extreme temperature sensitivity at 2967 m (vegetation) and 2897 m (snow), and both altitudes exhibit a positive trend during the measurement period.

  18. Coincidence of the alpine-nival ecotone with the summer snowline

    Energy Technology Data Exchange (ETDEWEB)

    Gottfried, M; Toechterle, R; Grabherr, G [Research Platform Mountain Limits, University of Vienna, Faculty Center of Biodiversity, Rennweg 14, Wien 1030 (Austria); Hantel, M; Maurer, C [Research Platform Mountain Limits, University of Vienna, Theoretical Meteorology Research Forum, Berggasse 11, Wien 1090 (Austria); Pauli, H, E-mail: michael.hantel@univie.ac.at [Institute of Mountain Research (IGF), Austrian Academy of Sciences, c/o Faculty Center of Biodiversity, University of Vienna, Rennweg 14, 1030 Wien (Austria)

    2011-01-15

    The alpine-nival ecotone is the transition between the lower located alpine grassland/tundra zone and the upper located sparsely vegetated nival zone in the mountains. Its characteristics are qualitatively known. Here we study the dynamics of the ecotone through a quantitative approach based on plant data (from Mt Schrankogel, 3497 m, observations 1994 and 2004) and snow data (from 268 routine climate stations in the Alps, observations 1975-2004). We introduce the nivality index as the area ratio of nival and alpine plants, and the snow duration as the length of the summer snow cover. We fit a nonlinear probabilistic model to our field data; it yields state functions of both quantities. The nivality index curve comprises the entire information of the plant data in one analytical function; the snow duration curve represents the equivalent for the full snow data set. Thus all relevant parameters of both quantities follow from the respective state function. We find that the analytical profile of the alpine-nival ecotone at Mt Schrankogel (based on nivality index observations from the altitude interval 2910-3090 m) happens to sit right in the center of the independently determined summer snow profile across the entire Alps; specifically, the central altitude of the Schrankogel ecotone coincides almost perfectly with the central altitude of Alpine snow duration. Both state functions show extreme temperature sensitivity at 2967 m (vegetation) and 2897 m (snow), and both altitudes exhibit a positive trend during the measurement period.

  19. A beta ray spectrometer based on a two-, or three-element silicon detector coincidence telescope

    International Nuclear Information System (INIS)

    Horowitz, Y.S.; Weizman, Y.; Hirning, C.R.

    1995-01-01

    The operation of a beta ray energy spectrometer based on a two-or three-element silicon detector telescope is described. The front detector (A) is a thin, totally depleted, silicon surface barrier detector either 40 μm, 72 μm or 98 μm thick. The back detector (C) is a Li compensated silicon detector, 5000 μm thick. An additional thin detector can be inserted between these two detectors when additional photon rejection capability is required in intense photon fields. The capability of the spectrometer to reject photons is based on the fact that incident photons will have a small probability of simultaneously losing detectable energy in two detectors and an even smaller probability of losing detectable energy in all three detectors. Electrons, however, above a low energy threshold, will always record simultaneous, events in all three detectors. The spectrometer is capable of measuring electron energies from a lower energy coincidence threshold of 70 keV with 60% efficiency increasing to 100% efficiency in the energy region between 150 keV and 2.5 MeV. (Author)

  20. Summing coincidence errors using Eu-152 lungs to calibrate a lung-counting system: are they significant?

    International Nuclear Information System (INIS)

    Kramer, Gary H.; Lynch, Timothy P.; Lopez, Maria A.; Hauck, Brian

    2004-01-01

    The use of a lung phantom containing 152Eu/241Am activity can provide a sufficient number of energy lines to generate an efficiency calibration for the in vivo measurements of radioactive materials in the lungs. However, due to the number of energy lines associated with 152Eu, coincidence summing occurs and can present a problem when using such a phantom for calibrating lung-counting systems. A Summing Peak Effect Study was conducted at three laboratories to determine the effect of using an efficiency calibration based on a 152Eu/241Am lung phantom. The measurement data at all three laboratories showed the presence of sum peaks. However, two of the three laboratories found only small biases (<5%) when using the 152Eu/241Am calibration. The third facility noted a 25% to 30% positive bias in the 140-keV to 190-keV energy range that prevents the use of the 152Eu/241Am lung phantom for routine calibrations. Although manufactured by different vendors, the three facilities use similar types of detectors (38 cm2 by 25 mm thick or 38 cm2 by 30 mm thick) for counting. These study results underscore the need to evaluate the coincidence summing effect when using a nuclide such as 152Eu for the calibration of low energy lung counting systems

  1. Visuo-perceptual capabilities predict sensitivity for coinciding auditory and visual transients in multi-element displays.

    Science.gov (United States)

    Meyerhoff, Hauke S; Gehrer, Nina A

    2017-01-01

    In order to obtain a coherent representation of the outside world, auditory and visual information are integrated during human information processing. There is remarkable variance among observers in the capability to integrate auditory and visual information. Here, we propose that visuo-perceptual capabilities predict detection performance for audiovisually coinciding transients in multi-element displays due to severe capacity limitations in audiovisual integration. In the reported experiment, we employed an individual differences approach in order to investigate this hypothesis. Therefore, we measured performance in a useful-field-of-view task that captures detection performance for briefly presented stimuli across a large perceptual field. Furthermore, we measured sensitivity for visual direction changes that coincide with tones within the same participants. Our results show that individual differences in visuo-perceptual capabilities predicted sensitivity for the presence of audiovisually synchronous events among competing visual stimuli. To ensure that this correlation does not stem from superordinate factors, we also tested performance in an unrelated working memory task. Performance in this task was independent of sensitivity for the presence of audiovisually synchronous events. Our findings strengthen the proposed link between visuo-perceptual capabilities and audiovisual integration. The results also suggest that basic visuo-perceptual capabilities provide the basis for the subsequent integration of auditory and visual information.

  2. Development of an ultrahigh-resolution Si-PM-based dual-head GAGG coincidence imaging system

    Science.gov (United States)

    Yamamoto, Seiichi; Watabe, Hiroshi; Kanai, Yasukazu; Kato, Katsuhiko; Hatazawa, Jun

    2013-03-01

    A silicon photomultiplier (Si-PM) is a promising photodetector for high resolution PET systems due to its small channel size and high gain. Using Si-PMs, it will be possible to develop a high resolution imaging systems. For this purpose, we developed a small field-of-view (FOV) ultrahigh-resolution Si-PM-based dual-head coincidence imaging system for small animals and plant research. A new scintillator, Ce doped Gd3Al12Ga3O12 (GAGG), was selected because of its high light output and its emission wavelength matched with the Si-PM arrays and contained no radioactivity. Each coincidence imaging block detector consists of 0.5×0.5×5 mm3 GAGG pixels combined with a 0.1-mm thick reflector to form a 20×17 matrix that was optically coupled to a Si-PM array (Hamamatsu MPPC S11064-050P) with a 1.5-mm thick light guide. The GAGG block size was 12.0×10.2 mm2. Two GAGG block detectors were positioned face to face and set on a flexible arm based detector stand. All 0.5 mm GAGG pixels in the block detectors were clearly resolved in the 2-dimensional position histogram. The energy resolution was 14.4% FWHM for the Cs-137 gamma ray. The spatial resolution was 0.7 mm FWHM measured using a 0.25 mm diameter Na-22 point source. Small animal and plant images were successfully obtained. We conclude that our developed ultrahigh-resolution Si-PM-based dual-head coincidence imaging system is promising for small animal and plant imaging research.

  3. Electron irradiation effect of polyurethane using coincidence doppler-broadening spectroscopy

    International Nuclear Information System (INIS)

    Yang, D.J.; Zhang, J.D.; Leung, J.K.C.; Beling, C.D.; Liu, L.B.

    2006-01-01

    Full text: To understand the electron irradiation effects on polymer, polyether-urethane (ETPU) samples of 2m m in thickness and 1 0 m m in diameter were irradiated by a 1.8M eV electron beam with beam current of 3 ma at room temperature. The irradiated doses are 5 kGy, 10 kGy, 15 kGy, 30 kGy, 100 kGy and 150 kGy. ETPU was manufactured by mixing PTMG-100, TDI-100 and MOCA. The momentum density distributions (MMDs) of electrons taking part in the annihilation processes of positron-electron pairs in ETPU have been measured by coincidence Doppler-broadening spectroscopy (CDBS). By presenting the ratio of the counts in every channel of the measured CDB spectrum to the corresponding counts from a reference spectrum (pristine ETPU), we observed that the change in MMDs is not significant for doses lower than 10 kGy. However, high momentum part of MMDs exhibit an obvious decrease for dose exceeding 15 kGy and then slowly down to steady with doses until 150 kGy. This valley occurs at around 15 x1 0 3m οc and is well known as oxygen-specific, indicative of a less positron trapping by oxygen atoms in some samples of higher dose radiation. It is postulated that the radiation will break the crosslinkings, allowing the trace water and oxygen molecules to be released from the sample surface. Excess NCO groups in ETPU would crosslink with urethane and urea groups to produce allophanate and biuret groups. After receiving a certain amount of electron irradiation, crosslinked allophanate and biuret groups would produce degradation. Thus, residual water and oxygen trapped in ETPU by the crosslinking would diffuse out. However, the irradiation doses up to 150 kGy in this experiment are still not large enough to induce strong degradation of urethane and urea groups

  4. Isotope analytics for the evaluation of the feeding influence on the isotope ratio in beef samples; Isotopenanalytik zur Bestimmung des Einflusses der Ernaehrung auf die Isotopenzusammensetzung in Rinderproben

    Energy Technology Data Exchange (ETDEWEB)

    Herwig, Nadine

    2010-11-17

    Information about the origin of food and associated production systems has a high significance for food control. An extremely promising approach to obtain such information is the determination of isotope ratios of different elements. In this study the correlation of the isotope ratios C-13/C-12, N-15/N-14, Mg-25/Mg-24, and Sr-87/Sr-86 in bovine samples (milk and urine) and the corresponding isotope ratios in feed was investigated. It was shown that in the bovine samples all four isotope ratios correlate with the isotope composition of the feed. The isotope ratios of strontium and magnesium have the advantage that they directly reflect the isotope ratios of the ingested feed since there is no isotope fractionation in the bovine organism which is in contrast to the case of carbon and nitrogen isotope ratios. From the present feeding study it is evident, that a feed change leads to a significant change in the delta C-13 values in milk and urine within 10 days already. For the deltaN-15 values the feed change was only visible in the bovine urine after 49 days. Investigations of cows from two different regions (Berlin/Germany and Goestling/Austria) kept at different feeding regimes revealed no differences in the N-15/N-14 and Mg-26/Mg-24 isotope ratios. The strongest correlation between the isotope ratio of the bovine samples and the kind of ingested feed was observed for the carbon isotope ratio. With this ratio even smallest differences in the feed composition were traceable in the bovine samples. Since different regions usually coincide with different feeding regimes, carbon isotope ratios can be used to distinguish bovine samples from different regions if the delta C-13 values of the ingested feed are different. Furthermore, the determination of strontium isotope ratios revealed significant differences between bovine and feed samples of Berlin and Goestling due to the different geologic realities. Hence the carbon and strontium isotope ratios allow the best

  5. Recovering the triple coincidence of non-pure positron emitters in preclinical PET

    Science.gov (United States)

    Lin, Hsin-Hon; Chuang, Keh-Shih; Chen, Szu-Yu; Jan, Meei-Ling

    2016-03-01

    Non-pure positron emitters, with their long half-lives, allow for the tracing of slow biochemical processes which cannot be adequately examined by the commonly used short-lived positron emitters. Most of these isotopes emit high-energy cascade gamma rays in addition to positron decay that can be detected and create a triple coincidence with annihilation photons. Triple coincidence is discarded in most scanners, however, the majority of the triple coincidence contains true photon pairs that can be recovered. In this study, we propose a strategy for recovering triple coincidence events to raise the sensitivity of PET imaging for non-pure positron emitters. To identify the true line of response (LOR) from a triple coincidence, a framework utilizing geometrical, energy and temporal information is proposed. The geometrical criterion is based on the assumption that the LOR with the largest radial offset among the three sub pairs of triple coincidences is least likely to be a true LOR. Then, a confidence time window is used to test the valid LOR among those within triple coincidence. Finally, a likelihood ratio discriminant rule based on the energy probability density distribution of cascade and annihilation gammas is established to identify the true LOR. An Inveon preclinical PET scanner was modeled with GATE (GEANT4 application for tomographic emission) Monte Carlo software. We evaluated the performance of the proposed method in terms of identification fraction, noise equivalent count rates (NECR), and image quality on various phantoms. With the inclusion of triple coincidence events using the proposed method, the NECR was found to increase from 11% to 26% and 19% to 29% for I-124 and Br-76, respectively, when 7.4-185 MBq of activity was used. Compared to the reconstructed images using double coincidence, this technique increased the SNR by 5.1-7.3% for I-124 and 9.3-10.3% for Br-76 within the activity range of 9.25-74 MBq, without compromising the spatial resolution or

  6. Determination of true coincidence correction factors using Monte-Carlo simulation techniques

    Directory of Open Access Journals (Sweden)

    Chionis Dionysios A.

    2014-01-01

    Full Text Available Aim of this work is the numerical calculation of the true coincidence correction factors by means of Monte-Carlo simulation techniques. For this purpose, the Monte Carlo computer code PENELOPE was used and the main program PENMAIN was properly modified in order to include the effect of the true coincidence phenomenon. The modified main program that takes into consideration the true coincidence phenomenon was used for the full energy peak efficiency determination of an XtRa Ge detector with relative efficiency 104% and the results obtained for the 1173 keV and 1332 keV photons of 60Co were found consistent with respective experimental ones. The true coincidence correction factors were calculated as the ratio of the full energy peak efficiencies was determined from the original main program PENMAIN and the modified main program PENMAIN. The developed technique was applied for 57Co, 88Y, and 134Cs and for two source-to-detector geometries. The results obtained were compared with true coincidence correction factors calculated from the "TrueCoinc" program and the relative bias was found to be less than 2%, 4%, and 8% for 57Co, 88Y, and 134Cs, respectively.

  7. Instrumentation and procedures for moisture corrections to passive neutron coincidence counting assays of bulk PuO2 and MOX powders

    International Nuclear Information System (INIS)

    Stewart, J.E.; Menlove, H.O.; Ferran, R.R.; Aparo, M.; Zeppa, P.; Troiani, F.

    1993-05-01

    For passive neutron-coincidence-counting verification measurements of PuO 2 and MOX powder, assay biases have been observed that result from moisture entrained in the sample. This report describes a unique set of experiments in which MOX samples, with a range of moisture concentrations, were produced and used to calibrate and evaluate two prototype moisture monitors. A new procedure for moisture corrections to PuO 2 and MOX verification measurements yields MOX assays accurate to 1.5% (1σ) for 0.6- and 1.1-kg samples. Monte Carlo simulations were used to extend the measured moisture calibration data to higher sample masses. A conceptual design for a high-efficiency neutron coincidence counter with improved sensitivity to moisture is also presented

  8. Numerical expressions for the computation of coincidence-summing correction factors in gamma-ray spectrometry with HPGe detectors

    International Nuclear Information System (INIS)

    Rizzo, S.; Tomarchio, E.

    2008-01-01

    Full text: The analytical relations used to compute the coincidence-summing effects on spectral response of Ge semiconductor detectors are quite complex and involve full-energy peak and total efficiencies. For point-sources, a general method for calculating the correction factors for gamma ray coincidences has been formulated by Andreev et al. and used by Schima and Hoppes to obtain γ-X K coincidence correction expressions for 17 nuclides. However, because the higher-order terms are neglected, the expressions supplied do not give reliable results in the case of short sample-detector distances. Using the formulae given by Morel et al.[3] and Lepy et al.[4], we have developed a computer program able to get numerical expressions to compute γ-γ e γ-X K coincidence summing corrections for point sources. Only full-energy peak and total efficiencies are needed. Alternatively, values of peak-to-total ratio can be introduced. For extended sources, the same expressions can be always considered with the introduction of 'effective efficiencies' as defined by Arnold and Sima, i.e. an average over the source volume of the spatial distribution of the elementary photon source total efficiency, weighted by the corresponding peak efficiency. We have considered the most used calibration radioisotopes as well as fission products, activation products and environmental isotopes. All decay data were taken from the most recent volumes of 'Table of Radionuclides', CEA Monographie BIPM-5 and a suitable matrix representation of a decay scheme was adopted. For the sake of brevity, we provide for each nuclide a set of expressions for the more intense gamma emissions, considered sufficient for most applications. However, numerical expressions are available for all the stored gamma transitions and can be obtained on request. As examples of the use of the expressions, the evaluation of correction values for point sources and a particulate sample reduced to a 6x6x0.7 cm packet - with reference

  9. Determination iodine in biological materials using instrumental neutron activation and anti-coincidence gamma-ray spectrometry

    International Nuclear Information System (INIS)

    Zhang, W.H.; Chatt, A.

    1997-01-01

    Iodine is an element of interest in nutritional research. Its lower limit of safe and adequate daily dietary intake for adults varies between 150 and 200 micrograms per day. In the present study, an epithermal instrumental neutron activation analysis (EINAA) method in conjunction with anti-coincidence counting has been developed for the determination of ppb levels of iodine in individual food items. Typically 200-300 mg of a sample are irradiated for 10 or 20 minutes at the Dalhousie University SLOWPOKE-2 reactor in an epithermal flux of 1x10 11 n cm -2 s -1 , followed by 1 min decay and then counting for 30 min. The 443-keV gamma-ray of 128 I is used for measuring iodine content by anti-coincidence counting. The anti-coincidence spectrometer consists of a 25% HPGe detector surrounded by a 10''x10'' NaI(TI) annulus and a 3''x3'' NaI(TI) plug. This system has a peak-to-Compton ratio of about 650 to 1 for the 661.6-keV photopeak of 137 Cs. The Compton background resulting from the scattering of many gamma-rays of energies higher than 443 keV can be reduced by a factor of about 4 using anti-coincidence counting compared to conventional counting. The detection limit for iodine can be improved by a factor of 2 to 5 depending on the sample matrix, dead time, position of the annulus and counting geometry among several other factors.The lowest detection limit of 5 ppb can be achieved for low-salt foods. This limit is comparable to that obtained by a preconcentration NAA (PNAA) method. However, a detection limit of 20 ppb is more realistic for samples containing high amounts of Na, Cl and Al. The results obtained for many reference materials are in good agreement with the certified values and those reported by the PNAA method. Details of the methods and results will be reported

  10. Determination iodine in biological materials using instrumental neutron activation and anti-coincidence gamma-ray spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, W.H.; Chatt, A. [Dalhousie University, Halifax, Nova Scotia (Canada). Radiochemistry Research Laboratory

    1997-10-01

    Iodine is an element of interest in nutritional research. Its lower limit of safe and adequate daily dietary intake for adults varies between 150 and 200 micrograms per day. In the present study, an epithermal instrumental neutron activation analysis (EINAA) method in conjunction with anti-coincidence counting has been developed for the determination of ppb levels of iodine in individual food items. Typically 200-300 mg of a sample are irradiated for 10 or 20 minutes at the Dalhousie University SLOWPOKE-2 reactor in an epithermal flux of 1x10{sup 11} n cm{sup -2} s{sup -1}, followed by 1 min decay and then counting for 30 min. The 443-keV gamma-ray of {sup 128}I is used for measuring iodine content by anti-coincidence counting. The anti-coincidence spectrometer consists of a 25% HPGe detector surrounded by a 10``x10`` NaI(TI) annulus and a 3``x3`` NaI(TI) plug. This system has a peak-to-Compton ratio of about 650 to 1 for the 661.6-keV photopeak of {sup 137}Cs. The Compton background resulting from the scattering of many gamma-rays of energies higher than 443 keV can be reduced by a factor of about 4 using anti-coincidence counting compared to conventional counting. The detection limit for iodine can be improved by a factor of 2 to 5 depending on the sample matrix, dead time, position of the annulus and counting geometry among several other factors.The lowest detection limit of 5 ppb can be achieved for low-salt foods. This limit is comparable to that obtained by a preconcentration NAA (PNAA) method. However, a detection limit of 20 ppb is more realistic for samples containing high amounts of Na, Cl and Al. The results obtained for many reference materials are in good agreement with the certified values and those reported by the PNAA method. Details of the methods and results will be reported 6 refs., 2 tabs.

  11. Theoretical and Experimental Investigations of Coincidences in Poisson Distributed Pulse Trains and Spectral Distortion Caused by Pulse Pileup.

    Science.gov (United States)

    Bristow, Quentin

    1990-01-01

    Part one of this two-part study is concerned with the multiple coincidences in pulse trains from X-ray and gamma radiation detectors which are the cause of pulse pileup. A sequence of pulses with inter-arrival times less than tau, the resolving time of the pulse-height analysis system used to acquire spectra, is called a multiple pulse string. Such strings can be classified on the basis of the number of pulses they contain, or the number of resolving times they cover. The occurrence rates of such strings are derived from theoretical considerations. Logic circuits were devised to make experimental measurements of multiple pulse string occurrence rates in the output from a NaI(Tl) scintillation detector over a wide range of count rates. Markov process theory was used to predict state transition rates in the logic circuits, enabling the experimental data to be checked rigorously for conformity with those predicted for a Poisson distribution. No fundamental discrepancies were observed. Part two of the study is concerned with a theoretical analysis of pulse pileup and the development of a discrete correction algorithm, based on the use of a function to simulate the coincidence spectrum produced by partial sums of pulses. Monte Carlo simulations, incorporating criteria for pulse pileup inherent in the operation of modern ADC's, were used to generate pileup spectra due to coincidences between two pulses, (1st order pileup) and three pulses (2nd order pileup), for different semi-Gaussian pulse shapes. Coincidences between pulses in a single channel produced a basic probability density function spectrum which can be regarded as an impulse response for a particular pulse shape. The use of a flat spectrum (identical count rates in all channels) in the simulations, and in a parallel theoretical analysis, showed the 1st order pileup distorted the spectrum to a linear ramp with a pileup tail. The correction algorithm was successfully applied to correct entire spectra for 1st and

  12. Efficiency calibration and coincidence summing correction for large arrays of NaI(Tl) detectors in soccer-ball and castle geometries

    International Nuclear Information System (INIS)

    Anil Kumar, G.; Mazumdar, I.; Gothe, D.A.

    2009-01-01

    Efficiency calibration and coincidence summing correction have been performed for two large arrays of NaI(Tl) detectors in two different configurations. They are, a compact array of 32 conical detectors of pentagonal and hexagonal shapes in soccer-ball geometry and an array of 14 straight hexagonal NaI(Tl) detectors in castle geometry. Both of these arrays provide a large solid angle of detection, leading to considerable coincidence summing of gamma rays. The present work aims to understand the effect of coincidence summing of gamma rays while determining the energy dependence of efficiencies of these two arrays. We have carried out extensive GEANT4 simulations with radio-nuclides that decay with a two-step cascade, considering both arrays in their realistic geometries. The absolute efficiencies have been simulated for gamma energies from 700 to 2800 keV using four different double-photon emitters, namely, 60 Co, 46 Sc, 94 Nb and 24 Na. The efficiencies so obtained have been corrected for coincidence summing using the method proposed by Vidmar et al. . The simulations have also been carried out for the same energies assuming mono-energetic point sources, for comparison. Experimental measurements have also been carried out using calibrated point sources of 137 Cs and 60 Co. The simulated and the experimental results are found to be in good agreement. This demonstrates the reliability of the correction method for efficiency calibration of two large arrays in very different configurations.

  13. Efficiency calibration and coincidence summing correction for large arrays of NaI(Tl) detectors in soccer-ball and castle geometries

    Energy Technology Data Exchange (ETDEWEB)

    Anil Kumar, G., E-mail: anilg@tifr.res.i [Department of Nuclear and Atomic Physics, Tata Institute of Fundamental Research, Homi Bhabha Road, Colaba, Mumbai 400005 (India); Mazumdar, I.; Gothe, D.A. [Department of Nuclear and Atomic Physics, Tata Institute of Fundamental Research, Homi Bhabha Road, Colaba, Mumbai 400005 (India)

    2009-11-21

    Efficiency calibration and coincidence summing correction have been performed for two large arrays of NaI(Tl) detectors in two different configurations. They are, a compact array of 32 conical detectors of pentagonal and hexagonal shapes in soccer-ball geometry and an array of 14 straight hexagonal NaI(Tl) detectors in castle geometry. Both of these arrays provide a large solid angle of detection, leading to considerable coincidence summing of gamma rays. The present work aims to understand the effect of coincidence summing of gamma rays while determining the energy dependence of efficiencies of these two arrays. We have carried out extensive GEANT4 simulations with radio-nuclides that decay with a two-step cascade, considering both arrays in their realistic geometries. The absolute efficiencies have been simulated for gamma energies from 700 to 2800 keV using four different double-photon emitters, namely, {sup 60}Co, {sup 46}Sc, {sup 94}Nb and {sup 24}Na. The efficiencies so obtained have been corrected for coincidence summing using the method proposed by Vidmar et al. . The simulations have also been carried out for the same energies assuming mono-energetic point sources, for comparison. Experimental measurements have also been carried out using calibrated point sources of {sup 137}Cs and {sup 60}Co. The simulated and the experimental results are found to be in good agreement. This demonstrates the reliability of the correction method for efficiency calibration of two large arrays in very different configurations.

  14. A theoretical basis for the analysis of multiversion software subject to coincident errors

    Science.gov (United States)

    Eckhardt, D. E., Jr.; Lee, L. D.

    1985-01-01

    Fundamental to the development of redundant software techniques (known as fault-tolerant software) is an understanding of the impact of multiple joint occurrences of errors, referred to here as coincident errors. A theoretical basis for the study of redundant software is developed which: (1) provides a probabilistic framework for empirically evaluating the effectiveness of a general multiversion strategy when component versions are subject to coincident errors, and (2) permits an analytical study of the effects of these errors. An intensity function, called the intensity of coincident errors, has a central role in this analysis. This function describes the propensity of programmers to introduce design faults in such a way that software components fail together when executing in the application environment. A condition under which a multiversion system is a better strategy than relying on a single version is given.

  15. Standardization of 241Am by digital coincidence counting, liquid scintillation counting and defined solid angle counting

    International Nuclear Information System (INIS)

    Balpardo, C.; Capoulat, M.E.; Rodrigues, D.; Arenillas, P.

    2010-01-01

    The nuclide 241 Am decays by alpha emission to 237 Np. Most of the decays (84.6%) populate the excited level of 237 Np with energy of 59.54 keV. Digital coincidence counting was applied to standardize a solution of 241 Am by alpha-gamma coincidence counting with efficiency extrapolation. Electronic discrimination was implemented with a pressurized proportional counter and the results were compared with two other independent techniques: Liquid scintillation counting using the logical sum of double coincidences in a TDCR array and defined solid angle counting taking into account activity inhomogeneity in the active deposit. The results show consistency between the three methods within a limit of a 0.3%. An ampoule of this solution will be sent to the International Reference System (SIR) during 2009. Uncertainties were analysed and compared in detail for the three applied methods.

  16. Instrumentation and data handling. I. Positron coincidence imaging with the TOKIM system

    International Nuclear Information System (INIS)

    Anon.

    1976-01-01

    In addition to the conventional singles mode of operation, the TOKIM system's two Anger-type gamma cameras may be used in the (stationary, 180 0 opposition) coincidence mode, making it possible to achieve tomographic imaging with three-dimensional spatial resolution and high detection sensitivity, utilizing β + emitting radioisotopes. This method, however, suffers from certain inherent limitations. Our efforts during this past year to improve upon the TOKIM imaging capability in the β + mode have been directed towards the reduction of the limitations by the following means: the removal of out of focal plane image contributions through a computerized iterative correction procedure, coupled with coincidence aperture limitation to achieve uniform sensitivity across a reasonable portion of the detector pair diameter, and the application of Muehllehner's graded filter approach to the TOKIM to increase the ratio of usable coincidence events versus singles count rate

  17. System for ν-ν-coincidence spectra processing with data compression

    International Nuclear Information System (INIS)

    Byalko, A.A.; Volkov, N.G.; Tsupko-Sitnikov, V.M.; Churakov, A.K.

    1982-01-01

    Calculational algorithm and program for analyzing gamma-gamma coincidence spectra based on using the method of expansion in singular values for data compression (the SVD method) are described. Results of the testing of the program during the processing of coincidence spectrum for the low-energy region of transitions corresponding to decay 164 Lu → 164 Yb are given. The program is written in the FORTRAN language and is realized by the ES-1040 computer. The counting time constitutes about 20 min. It is concluded that the use of the SVD method permits to correct the data at the expense of distortion filtration caused with statistical deviations and random interferences, at that not distorting the initial data. The data compressed correspond more to theoretical suggestions of forms of semiconductor detector lines and two-dimensional line in the coincidence spectrum

  18. Determination of U-235 quantity in fresh fuel elements by neutron coincidence collar technique

    International Nuclear Information System (INIS)

    Almeida, M.C.M. de; Almeida, S.G. de; Marzo, M.A.S.; Moita, L.P.M.

    1990-01-01

    The U-235 quantity per lenght of fresh fuel assemblies of the Angra-I first recharge was determined by Neutron Coincidence Collar technique (N.C.C.). This technique is well-founded in fresh fuel assemblies activation by thermal neutrons from AmLi source to generate U-235 fission neutrons. These neutrons are detected by coincidence method in polyethylene structure where 18 He-3 detectors were placed. The coincidence counting results, in active mode (AmLi), showed 0,7% to standard deviation and equal to 1,49% to mass in 1000s of counting. The accuracies of different calibration methods were evaluated and compared. The results showed that the operator declared values are consistent. This evaluation was part of technical-exchange program between Safeguards Laboratory from C.N.E.N. and Los Alamos National Lab., United States. (author)

  19. Development of a photometric measuring method for soot analysis in flames. Final report; Entwicklung eines photometrischen Messverfahrens zur Russanalyse in Flammen. Abschlussbericht

    Energy Technology Data Exchange (ETDEWEB)

    Weichert, R.; Niemann, J.

    1995-12-31

    The present photometric measuring method for soot analysis in flames meets the following specifications: determination of the volume concentration of soot particles from 2 x 10{sup -7} upwards by means of extinction measurement at three different wavelengths; determination of the particle size distribution of soot particles by means of nephelometry in the range betwenn 20 and 400 nm; contactless measurements on the particle collective in the flame; no need for calibration of the photometric measuring method on the basis of particles of known size and concentration. (orig./SR) [Deutsch] Es ergeben sich fuer das entwickelte photometrische Messverfahren zur Russanalyse in Flammen folgende Spezifikationen: - Bestimmung der Volumenkonzentration der Russpartikel ab 2 x 10{sup -7} mittels Extinktionsmessungen bei drei Lichtwellenlaengen, - Ermittlung der Partikelgroessenverteilung der Russpartikel aus Streulichtmessungen im Bereich von 20 bis 400 nm, - beruehrungsfreie Messung in der Flamme am Partikelkollektiv und, - keine Kalibrierung des photometrischen Messverfahrens mit Partikeln bekannter Groesse bzw. bekannter Konzentration erforderlich. (orig./SR)

  20. Study of rare neutron induced processes and coincidence analyses to identify and reduce background contributions in the COBRA experiment

    International Nuclear Information System (INIS)

    Timm, Jan Horst Karl

    2015-11-01

    The aim of the COBRA experiment is the observation of neutrinoless double-beta decay, primarily of the isotope 116 Cd. The applied semiconductor detectors of cadmium zinc telluride that are 90% to be enriched enable both the detection and the source of this decay. The half-lives of decays of this kind are expected in the range of more than 10 26 years. Therefore, the reduction of contributions to the background is of decisive importance. The main subjects of this work are, on the one hand, the time synchronization of the data, which provides the basis for coincidence analysis. This analysis method has access not only to identification of contributions to the background, but also to observe decays involving positron annihilation and decays into excited states. In this study, the intrinsic detector contamination of some decay products of 238 U and 232 Th was measured and sensitivities to the half-lives of the decays like 120 Te and 128 Te in each case to the first excited state of daughter products are given. On the other hand, qualitative studies on the importance of neutrons in the COBRA experiment were conducted. These have shown that fast neutrons, thus with energies greater than 10 keV, only result in an insignificant contribution to the background for the detection of neutrinoless double-beta decay of the 116 Cd. Previous studies have also shown that the thermal neutron flux can be in situ determined by coincidence analysis.

  1. Fast digital 4πβ-4πγ coincidence counting with offline analysis at IRA.

    Science.gov (United States)

    Teresa Durán, M; Nedjadi, Youcef; Juget, Frédéric; Bochud, François; Bailat, Claude

    2018-04-01

    IRA recently launched a project to digitize all the data acquisition systems it uses for primary radionuclide standardizations. It is well-known that the digital approach presents numerous advantages over the traditional analog electronics such as information losslessness, scalability, online and/or offline data processing, and it is also a solution to the growing difficulties to repair or renew ageing modules. As a first step in this wider program, our institute set-up a 4πβ-4πγ digital coincidence counting system, with FPGA (Field Programmable Gate Array)-based commercial boards from National Instruments (NI), to perform data acquisition and offline data analysis. Choosing all components and software from the same supplier provides a full compact and consistent electronic system. To demonstrate and validate the capacity of this system to standardize the activity of radioisotopes, we compare its predictions for the activity concentration of 133 Ba, 166m Ho and 18 F solutions with the results from a coincidence counting system with analog electronics, as well as with the results from other primary methods and a secondary measurement performed with an IG11 ionization chamber (CIR, chambre d'ionization de référence) with an equivalent activity traceable to the Système International de Référence. Copyright © 2017 Elsevier Ltd. All rights reserved.

  2. On the determination of iridium in diverse geological samples employing HPGe-coincidence/NaI(Tl)-anticoincidence spectrometry

    Science.gov (United States)

    Murali, A. V.; Parekh, P. P.; Cumming, J. B.

    1990-01-01

    This paper reports the Ir content of a variety of geological samples determined by the high-purity Ge-coincidence/NaI(Tl)-anticoincidence gamma-ray spectrometry (henceforth referred to as coincidence/anticoincidence technique) and by the conventional INAA. The advantages of this technique are: (1) the Ir content of the samples is obtained (ppm to a fraction of ppb ranges) not only by the 468.1 keV peak as in the conventional INAA but also by the 784.6 keV and 920.9 keV sum peaks, which gives more confidence in the values obtained; and (2) it is well suited for the samples with high Compton background for which it is difficult to measure the Ir content by the conventional INAA technique. The practical sensitivity of this technique depends on the sample matrix. Under present experimental conditions, it varied from 0.1 ng for Mn nodules and 0.004 ng for Libyan Desert Glass. Iridium values obtained on small (about 1 microg) olivine grains demonstrate the potential application of this new technique to microsamples. The principle and methodology of this new technique as well as its advantages and disadvantages over the conventional INAA are discussed.

  3. Wavelength dependent photoelectron circular dichroism of limonene studied by femtosecond multiphoton laser ionization and electron-ion coincidence imaging

    Science.gov (United States)

    Rafiee Fanood, Mohammad M.; Janssen, Maurice H. M.; Powis, Ivan

    2016-09-01

    Enantiomers of the monoterpene limonene have been investigated by (2 + 1) resonance enhanced multiphoton ionization and photoelectron circular dichroism employing tuneable, circularly polarized femtosecond laser pulses. Electron imaging detection provides 3D momentum measurement while electron-ion coincidence detection can be used to mass-tag individual electrons. Additional filtering, by accepting only parent ion tagged electrons, can be then used to provide discrimination against higher energy dissociative ionization mechanisms where more than three photons are absorbed to better delineate the two photon resonant, one photon ionization pathway. The promotion of different vibrational levels and, tentatively, different electronic ion core configurations in the intermediate Rydberg states can be achieved with different laser excitation wavelengths (420 nm, 412 nm, and 392 nm), in turn producing different state distributions in the resulting cations. Strong chiral asymmetries in the lab frame photoelectron angular distributions are quantified, and a comparison made with a single photon (synchrotron radiation) measurement at an equivalent photon energy.

  4. Application of coincidence Doppler-broadening spectroscopy to different carbon phases

    International Nuclear Information System (INIS)

    Ito, Y.; Djourelov, N.; Suzuki, T.; Kondo, K.; Ito, Y.; Shantarovich, V.; Onoe, J.

    2004-01-01

    Coincidence Doppler-broadening spectroscopy was applied to C60 and C70 fullerenes and other carbon phases, such as nanotubes and graphites. Remarkable differences were observed in the Doppler-broadening of the positron annihilation γ-rays in these materials, which reflect the different densities distribution of the momentum for electrons annihilated with positrons. This would be caused by the different composition of the π and σ electrons in annihilation with positrons. This result shows the sensitivity of the coincidence Doppler-broadening method to determine the density distribution of electrons sampled by positrons. (orig.)

  5. Boron-Coated Straw Collar for Uranium Neutron Coincidence Collar Replacement

    International Nuclear Information System (INIS)

    Hu, Jianwei; Croft, Stephen; McElroy, Robert Dennis

    2017-01-01

    The objective of this project was to design and optimize, in simulation space, an active neutron coincidence counter (or collar) using boron-coated straws (BCSs) as a non- 3 He replacement to the Uranium Neutron Coincidence Collar (UNCL). UNCL has been used by the International Atomic Energy Agency (IAEA) and European Atomic Energy Community (Euratom) since the 1980s to verify the 235 U content in fresh light water reactor fuel assemblies for safeguards purposes. This report documents the design and optimization of the BCS collar.

  6. Boron-Coated Straw Collar for Uranium Neutron Coincidence Collar Replacement

    Energy Technology Data Exchange (ETDEWEB)

    Hu, Jianwei [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Croft, Stephen [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); McElroy, Robert Dennis [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2017-01-01

    The objective of this project was to design and optimize, in simulation space, an active neutron coincidence counter (or collar) using boron-coated straws (BCSs) as a non-3He replacement to the Uranium Neutron Coincidence Collar (UNCL). UNCL has been used by the International Atomic Energy Agency (IAEA) and European Atomic Energy Community (Euratom) since the 1980s to verify the 235U content in fresh light water reactor fuel assemblies for safeguards purposes. This report documents the design and optimization of the BCS collar.

  7. True coincidence summing correction and mathematical efficiency modeling of a well detector

    Energy Technology Data Exchange (ETDEWEB)

    Jäderström, H., E-mail: henrik.jaderstrom@canberra.com [CANBERRA Industries Inc., 800 Research Parkway, Meriden, CT 06450 (United States); Mueller, W.F. [CANBERRA Industries Inc., 800 Research Parkway, Meriden, CT 06450 (United States); Atrashkevich, V. [Stroitely St 4-4-52, Moscow (Russian Federation); Adekola, A.S. [CANBERRA Industries Inc., 800 Research Parkway, Meriden, CT 06450 (United States)

    2015-06-01

    True coincidence summing (TCS) occurs when two or more photons are emitted from the same decay of a radioactive nuclide and are detected within the resolving time of the gamma ray detector. TCS changes the net peak areas of the affected full energy peaks in the spectrum and the nuclide activity is rendered inaccurate if no correction is performed. TCS is independent of the count rate, but it is strongly dependent on the peak and total efficiency, as well as the characteristics of a given nuclear decay. The TCS effects are very prominent for well detectors because of the high efficiencies, and make accounting for TCS a necessity. For CANBERRA's recently released Small Anode Germanium (SAGe) well detector, an extension to CANBERRA's mathematical efficiency calibration method (In Situ Object Calibration Software or ISOCS, and Laboratory SOurceless Calibration Software or LabSOCS) has been developed that allows for calculation of peak and total efficiencies for SAGe well detectors. The extension also makes it possible to calculate TCS corrections for well detectors using the standard algorithm provided with CANBERRAS's Spectroscopy software Genie 2000. The peak and total efficiencies from ISOCS/LabSOCS have been compared to MCNP with agreements within 3% for peak efficiencies and 10% for total efficiencies for energies above 30 keV. A sample containing Ra-226 daughters has been measured within the well and analyzed with and without TCS correction and applying the correction factor shows significant improvement of the activity determination for the energy range 46–2447 keV. The implementation of ISOCS/LabSOCS for well detectors offers a powerful tool for efficiency calibration for these detectors. The automated algorithm to correct for TCS effects in well detectors makes nuclide specific calibration unnecessary and offers flexibility in carrying out gamma spectral analysis.

  8. DMSA-scintigraphy in paediatrics: is the evaluation of the geometric mean necessary for the calculation of the differential renal function?; Partialfunktionsberechnung der Nieren mit DMSA in der Paediatrie: ist fuer die Bestimmung das geometrische Mittel notwendig?

    Energy Technology Data Exchange (ETDEWEB)

    Porn, U.; Alalp, S.; Fischer, S.; Dresel, S. [Klinik und Poliklinik fuer Nuklearmedizin, Klinikum der Ludwig-Maximilians-Univ. Muenchen (Germany); Rossmueller, B. [Inst. fuer Radiologische Diagnostik, Klinikum der Ludwig-Maximilians-Univ. Muenchen (Germany); Hahn, K. [Klinik und Poliklinik fuer Nuklearmedizin, Klinikum der Ludwig-Maximilians-Univ. Muenchen (Germany); Inst. fuer Radiologische Diagnostik, Klinikum der Ludwig-Maximilians-Univ. Muenchen (Germany)

    2001-08-01

    cases with an obvious anatomical abnormality. (orig.) [German] Bei der statischen Nierenfunktionsszintigraphie mit Tc-99m-Dimercaptobernsteinsaeure (DMSA) wird zur moeglichst exakten Bestimmung der seitengetrennten Partialfunktion (PF) die Berechnung des geometrischen Mittels aus dorsaler und ventraler Projektion empfohlen. Ziel unserer Untersuchung war es, die allein aus der dorsalen Projektion ermittelte Partialfunktion (PF{sub dors}) mit der aus dem geometrischen Mittel berechneten PF (PF{sub geom}) zu vergleichen, um die Notwendigkeit der zusaetzlichen ventralen Projektion zu ueberpruefen. Methode: Es wurden 164 DMSA-Untersuchungen von 151 Kindern (86 w, 65 m) mit einem Alter von 16 d bis 16 a (4,7 {+-} 3,9 a) ausgewertet. Die Akquisition erfolgte mit einer Doppelkopfkamera aus ventraler und dorsaler Projektion (Picker Prism 2000 XP, LEUHR, Matrix: 256 x 256, 300 kcts/view, Zoom: 1,6-2,0). Mittels ROI-Auswertung wurden die Hintergrund-korrigierten Zaehlraten der beiden Nieren von ventral und dorsal bestimmt und die dorsalen Zaehlratenverhaeltnisse mit dem geometrischen Mittel (SQR[Cts{sub dors} x Cts{sub ventr}]) verglichen. Ergebnisse: Die PF{sub dors} ergab statistisch signifikant niedrigere Werte fuer die rechte Niere (bzw. entsprechend hoehere Werte fuer die linke Niere) im Vergleich zur PF{sub geom} (p<0,01). Die mittlere Differenz zwischen der PF{sub geom} und der PF{sub dors} betrug 1,5 {+-} 1,4%. Nur in 6/164 Faellen (3,7%) ergab sich ein Unterschied von {>=}5% (5,0-9,5%). Bei 3 dieser 6 Faelle lag die mit der PF{sub dors} unterschaetzte Niere (2 x links, 1 x rechts) kaudal dystop. Die uebrigen 3 Patienten mit einer Differenz von >5% zeigten keine Lage- oder Strukturanomalie. Schlussfolgerung: Die Berechnung der Partialfunktion ausschliesslich aus den dorsalen Projektionen fuehrt im Vgl. zur Berechnung durch das geometrische Mittel zu einer Unterschaetzung der PF der rechten Niere im Vergleich zur linken Niere. Dieser Effekt fuehrt jedoch bei orthotop

  9. VUV photoionization of acetamide studied by electron/ion coincidence spectroscopy in the 8–24 eV photon energy range

    International Nuclear Information System (INIS)

    Schwell, Martin; Bénilan, Yves; Fray, Nicolas; Gazeau, Marie-Claire; Es-Sebbar, Et.; Garcia, Gustavo A.; Nahon, Laurent; Champion, Norbert; Leach, Sydney

    2012-01-01

    Highlights: ► We study the VUV photoionization of acetamide in the 8–24 eV photon energy range. ► Electron/ion coincidence measurements are performed using synchrotron radiation. ► The adiabatic ionization energy of acetamide is determined by TPEPICO measurements. ► VUV induced fragmentation pathways of acetamide are assigned and discussed. - Abstract: A VUV photoionization study of acetamide was carried out over the 8–24 eV photon energy range using synchrotron radiation and photoelectron/photoion coincidence (PEPICO) spectroscopy. Threshold photoelectron photoion coincidence (TPEPICO) measurements were also made. Photoion yield curves and branching ratios were measured for the parent ion and six fragment ions. The adiabatic ionization energy of acetamide was determined as I.E. (1 2 A′) = (9.71 ± 0.02) eV, in agreement with an earlier reported photoionization mass spectrometry (PIMS) value. The adiabatic energy of the first excited state of the ion, 1 2 A″, was determined to be ≈10.1 eV. Assignments of the fragment ions and the pathways of their formation by dissociative photoionization were made. The neutral species lost in the principal dissociative photoionization processes are CH 3 , NH 2 , NH 3 , CO, HCCO and NH 2 CO. Heats of formation are derived for all ions detected and are compared with literature values. Some astrophysical implications of these results are discussed.

  10. THE LIMITED EFFECT OF COINCIDENT ORIENTATION ON THE CHOICE OF INTRINSIC AXIS (.).

    Science.gov (United States)

    Li, Jing; Su, Wei

    2015-06-01

    The allocentric system computes and represents general object-to-object spatial relationships to provide a spatial frame of reference other than the egocentric system. The intrinsic frame-of-reference system theory, which suggests people learn the locations of objects based upon an intrinsic axis, is important in research about the allocentric system. The purpose of the current study was to determine whether the effect of coincident orientation on the choice of intrinsic axis was limited. Two groups of participants (24 men, 24 women; M age = 24 yr., SD = 2) encoded different spatial layouts in which the objects shared the coincident orientation of 315° and 225° separately at learning perspective (0°). The response pattern of partial-scene-recognition task following learning reflected different strategies for choosing the intrinsic axis under different conditions. Under the 315° object-orientation condition, the objects' coincident orientation was as important as the symmetric axis in the choice of the intrinsic axis. However, participants were more likely to choose the symmetric axis as the intrinsic axis under the 225° object-orientation condition. The results suggest the effect of coincident orientation on the choice of intrinsic axis is limited.

  11. Constructing coincident indices of economic activity for the Latin American economy

    Directory of Open Access Journals (Sweden)

    João Victor Issler

    2013-03-01

    Full Text Available This paper has three main contributions. The first is to propose an individual coincident indicator for the following Latin American countries: Argentina, Brazil, Chile, Colombia and Mexico. In order to obtain similar series to those traditionally used in business-cycle research in constructing coincident indices (output, sales, income and employment we were forced to back-cast several individual country series which were not available in a long time-series span. The second contribution is to establish a chronology of recessions for these countries, covering the period from 1980 to 2012 on a monthly basis. Based on this chronology, the countries are compared in several respects. The final contribution is to propose an aggregate coincident indicator for the Latin American economy, which weights individual-country composite indices. Finally, this indicator is compared with the coincident indicator (The Conference Board - TCB of the U.S. economy. We find that the U.S. indicator Granger-causes the Latin American indicator in statistical tests

  12. Increased coincidence detection for quantum versus pseudo-generated random numbers

    NARCIS (Netherlands)

    Boshoff, Lieze; Jolij, Jacob

    2015-01-01

    People often see meaning in stimuli that are typically considered meaningless. According to Von Lucadou’s idea of Generalized Quantum Teory (GQT), such perceived coincidences, or examples of synchronicity, may be the result of entanglement between a conscious observer and the physical world. Here we

  13. Study of Thermal Equilibrium in Heavy Ion Collisions via the Ma Coincidence Method - Test of Applicability

    International Nuclear Information System (INIS)

    Kirejczyk, M.

    2002-01-01

    The coincidence method of judging whether a system reached thermal equilibrium is shortly presented. It is used on the model data to test, whether it is applicable in the low-relativistic energy range. Also, the cuts corresponding to real detectors are introduced and their influence is briefly discussed. (author)

  14. Pre-coincidence brain activity predicts the perceptual outcome of streaming/bouncing motion display.

    Science.gov (United States)

    Zhao, Song; Wang, Yajie; Jia, Lina; Feng, Chengzhi; Liao, Yu; Feng, Wenfeng

    2017-08-18

    When two identical visual discs move toward each other on a two-dimensional visual display, they can be perceived as either "streaming through" or "bouncing off" each other after their coincidence. Previous studies have observed a strong bias toward the streaming percept. Additionally, the incidence of the bouncing percept in this ambiguous display could be increased by various factors, such as a brief sound at the moment of coincidence and a momentary pause of the two discs. The streaming/bouncing bistable motion phenomenon has been studied intensively since its discovery. However, little is known regarding the neural basis underling the perceptual ambiguity in the classic version of the streaming/bouncing motion display. The present study investigated the neural basis of the perception disambiguating underling the processing of the streaming/bouncing bistable motion display using event-related potential (ERP) recordings. Surprisingly, the amplitude of frontal central P2 (220-260 ms) that was elicited by the moving discs ~200 ms before the coincidence of the two discs was observed to be predictive of subsequent streaming or bouncing percept. A larger P2 amplitude was observed for streaming percept than the bouncing percept. These findings suggest that the streaming/bouncing bistable perception may have been disambiguated unconsciously ~200 ms before the coincidence of the two discs.

  15. Pulse shaping for fast coincidence with NaI(Tl) detectors

    International Nuclear Information System (INIS)

    Bose, S.; Sinha, B.K.; Bhattacharya, R.

    1983-01-01

    The effect of multiple limiting of the anode pulses of the photomultiplier tubes on the resolving time of an NaI(Tl)-NaI(Tl) fast coincidence set up is investigated with the help of a simple transistored limiter circuit. The performance of the set up for different energy ranges selected in the side channels is also investigated. (orig.)

  16. Metformin and lactic acidosis : cause or coincidence? A review of case reports

    NARCIS (Netherlands)

    Stades, AME; Heikens, JT; Erkelens, DW; Holleman, F; Hoekstra, JBL

    Objective. Metformin has been associated with the serious side-effect lactic acidosis. However, it remains unclear whether the use of metformin was a cause or a coincidence in lactic acidosis. Design. A literature search of the Index Medicus (1959-66) and of the databases Embase, Medline, Medline

  17. Metformin and lactic acidosis: cause or coincidence? A review of case reports

    NARCIS (Netherlands)

    Stades, A. M. E.; Heikens, J. T.; Erkelens, D. W.; Holleman, F.; Hoekstra, J. B. L.

    2004-01-01

    Objective. Metformin has been associated with the serious side-effect lactic acidosis. However, it remains unclear whether the use of metformin was a cause or a coincidence in lactic acidosis. Design. A literature search of the Index Medicus (1959-66) and of the databases Embase, Medline, Medline

  18. Field test and calibration of neutron coincidence counters for high-mass plutonium samples

    International Nuclear Information System (INIS)

    Menlove, H.O.; Dickinson, R.J.; Douglas, I.

    1987-02-01

    Five different neutron coincidence systems were evaluated and calibrated for high-mass PuO 2 samples. The samples were from 2 to 7.2 kg of PuO 2 in mass, with a large range of burnup. This report compares the equipment and the results, with an evaluation of deadtime and multiplication corrections

  19. Interacting dark sector and the coincidence problem within the scope of LRS Bianchi type I model

    Science.gov (United States)

    Muharlyamov, Ruslan K.; Pankratyeva, Tatiana N.

    2018-05-01

    It is shown that a suitable interaction between dark energy and dark matter in locally rotationally symmetric (LRS) Bianchi-I space-time can solve the coincidence problem and not contradict the accelerated expansion of present Universe. The interaction parameters are estimated from observational data.

  20. The memory coincidence system (CALI). Principle and use for the multidetector experiments in nuclear physics

    International Nuclear Information System (INIS)

    Pouthas, J.

    1984-01-01

    In an experimental set up, the main function of the ''CALI system'' is to achieve ''coincidence'' between logic channels. This system also provides a fast selection of the events and their identification by a digital word, and the connection to the data acquisition system [fr