WorldWideScience

Sample records for coincidence counting applied

  1. Computed neutron coincidence counting applied to passive waste assay

    Energy Technology Data Exchange (ETDEWEB)

    Bruggeman, M.; Baeten, P.; De Boeck, W.; Carchon, R. [Nuclear Research Centre, Mol (Belgium)

    1997-11-01

    Neutron coincidence counting applied for the passive assay of fissile material is generally realised with dedicated electronic circuits. This paper presents a software based neutron coincidence counting method with data acquisition via a commercial PC-based Time Interval Analyser (TIA). The TIA is used to measure and record all time intervals between successive pulses in the pulse train up to count-rates of 2 Mpulses/s. Software modules are then used to compute the coincidence count-rates and multiplicity related data. This computed neutron coincidence counting (CNCC) offers full access to all the time information contained in the pulse train. This paper will mainly concentrate on the application and advantages of CNCC for the non-destructive assay of waste. An advanced multiplicity selective Rossi-alpha method is presented and its implementation via CNCC demonstrated. 13 refs., 4 figs., 2 tabs.

  2. Computed neutron coincidence counting applied to passive waste assay

    International Nuclear Information System (INIS)

    Bruggeman, M.; Baeten, P.; De Boeck, W.; Carchon, R.

    1997-01-01

    Neutron coincidence counting applied for the passive assay of fissile material is generally realised with dedicated electronic circuits. This paper presents a software based neutron coincidence counting method with data acquisition via a commercial PC-based Time Interval Analyser (TIA). The TIA is used to measure and record all time intervals between successive pulses in the pulse train up to count-rates of 2 Mpulses/s. Software modules are then used to compute the coincidence count-rates and multiplicity related data. This computed neutron coincidence counting (CNCC) offers full access to all the time information contained in the pulse train. This paper will mainly concentrate on the application and advantages of CNCC for the non-destructive assay of waste. An advanced multiplicity selective Rossi-alpha method is presented and its implementation via CNCC demonstrated. 13 refs., 4 figs., 2 tabs

  3. Digital coincidence counting

    International Nuclear Information System (INIS)

    Buckman, S.M.; Ius, D.

    1996-01-01

    This paper reports on the development of a digital coincidence-counting system which comprises a custom-built data acquisition card and associated PC software. The system has been designed to digitise the pulse-trains from two radiation detectors at a rate of 20 MSamples/s with 12-bit resolution. Through hardware compression of the data, the system can continuously record both individual pulse-shapes and the time intervals between pulses. Software-based circuits are used to process the stored pulse trains. These circuits are constructed simply by linking together icons representing various components such as coincidence mixers, time delays, single-channel analysers, deadtimes and scalers. This system enables a pair of pulse trains to be processed repeatedly using any number of different methods. Some preliminary results are presented in order to demonstrate the versatility and efficiency of this new method. (orig.)

  4. Digital coincidence counting

    Science.gov (United States)

    Buckman, S. M.; Ius, D.

    1996-02-01

    This paper reports on the development of a digital coincidence-counting system which comprises a custom-built data acquisition card and associated PC software. The system has been designed to digitise the pulse-trains from two radiation detectors at a rate of 20 MSamples/s with 12-bit resolution. Through hardware compression of the data, the system can continuously record both individual pulse-shapes and the time intervals between pulses. Software-based circuits are used to process the stored pulse trains. These circuits are constructed simply by linking together icons representing various components such as coincidence mixers, time delays, single-channel analysers, deadtimes and scalers. This system enables a pair of pulse trains to be processed repeatedly using any number of different methods. Some preliminary results are presented in order to demonstrate the versatility and efficiency of this new method.

  5. Fast counting electronics for neutron coincidence counting

    International Nuclear Information System (INIS)

    Swansen, J.E.

    1987-01-01

    This patent describes a high speed circuit for accurate neutron coincidence counting comprising: neutron detecting means for providing an above-threshold signal upon neutron detection; amplifying means inputted by the neutron detecting means for providing a pulse output having a pulse width of about 0.5 microseconds upon the input of each above threshold signal; digital processing means inputted by the pulse output of the amplifying means for generating a pulse responsive to each input pulse from the amplifying means and having a pulse width of about 50 nanoseconds effective for processing an expected neutron event rate of about 1 Mpps: pulse stretching means inputted by the digital processing means for producing a pulse having a pulse width of several milliseconds for each pulse received form the digital processing means; visual indicating means inputted by the pulse stretching means for producing a visual output for each pulse received from the digital processing means; and derandomizing means effective to receive the 50 ns neutron event pulses from the digital processing means for storage at a rate up to the neutron event rate of 1 Mpps and having first counter means for storing the input neutron event pulses

  6. Coincidence counting corrections for dead time losses and accidental coincidences

    International Nuclear Information System (INIS)

    Wyllie, H.A.

    1987-04-01

    An equation is derived for the calculation of the radioactivity of a source from the results of coincidence counting taking into account the dead-time losses and accidental coincidences. The derivation is an extension of the method of J. Bryant [Int. J. Appl. Radiat. Isot., 14:143, 1963]. The improvement on Bryant's formula has been verified by experiment

  7. Standardization of 241Am by digital coincidence counting, liquid scintillation counting and defined solid angle counting

    International Nuclear Information System (INIS)

    Balpardo, C.; Capoulat, M.E.; Rodrigues, D.; Arenillas, P.

    2010-01-01

    The nuclide 241 Am decays by alpha emission to 237 Np. Most of the decays (84.6%) populate the excited level of 237 Np with energy of 59.54 keV. Digital coincidence counting was applied to standardize a solution of 241 Am by alpha-gamma coincidence counting with efficiency extrapolation. Electronic discrimination was implemented with a pressurized proportional counter and the results were compared with two other independent techniques: Liquid scintillation counting using the logical sum of double coincidences in a TDCR array and defined solid angle counting taking into account activity inhomogeneity in the active deposit. The results show consistency between the three methods within a limit of a 0.3%. An ampoule of this solution will be sent to the International Reference System (SIR) during 2009. Uncertainties were analysed and compared in detail for the three applied methods.

  8. Statistical data filtration in neutron coincidence counting

    International Nuclear Information System (INIS)

    Beddingfield, D.H.; Menlove, H.O.

    1992-11-01

    We assessed the effectiveness of statistical data filtration to minimize the contribution of matrix materials in 200-ell drums to the nondestructive assay of plutonium. Those matrices were examined: polyethylene, concrete, aluminum, iron, cadmium, and lead. Statistical filtration of neutron coincidence data improved the low-end sensitivity of coincidence counters. Spurious data arising from electrical noise, matrix spallation, and geometric effects were smoothed in a predictable fashion by the statistical filter. The filter effectively lowers the minimum detectable mass limit that can be achieved for plutonium assay using passive neutron coincidence counting

  9. Recent progress with digital coincidence counting

    International Nuclear Information System (INIS)

    Butcher, K.S.A.; Watt, G.C.; Alexiev, D.

    1999-01-01

    Digital Coincidence Counting (DCC) is a new technique, based on the older method of analogue coincidence counting. It has been developed by ANSTO as a faster more reliable means of determining the activity of ionising radiation samples. The technique employs a dual channel analogue to digital converter acquisition system for collecting pulse information from a 4Π beta detector and a NaI(Tl) gamma detector. The digitised pulse information is stored on a high speed hard disk and timing information for both channels is also stored. The data may subsequently be recalled and analysed using software based algorithms. The system is operational and results are now being routinely collected and analysed. Some of the early work is presented for Co-60, Na-22 and Sm-153

  10. Method and apparstus for determining random coincidence count rate in a scintillation counter utilizing the coincidence technique

    International Nuclear Information System (INIS)

    Horrocks, D.L.

    1980-01-01

    A method and apparatus for the reliable determination of a random coincidence count attributable to chance coincidences of single-photon events which are each detected in only a single detector of a scintillation counter utilizing two detectors in a coincidence counting technique are described. A firstdelay device is employed to delay output pulses from one detector, and then the delayed signal is compared with the undelayed signal from the other detector in a coincidence circuit, to obtain an approximate random coincidence count. The output of the coincidence circuit is applied to an anti-coincidence circuit, where it is corrected by elimination of pulses coincident with, and attributable to, conventionally detected real coincidences, and by elimination of pulses coincident with, and attributable to, real coincidences that have been delayed by a second delay device having the same time parameter as the first. 8 claims

  11. Standardisation of 64Cu using a software coincidence counting system

    International Nuclear Information System (INIS)

    Havelka, Miroslav; Sochorová, Jana

    2014-01-01

    The activity of the radionuclide 64 Cu was determined by the efficiency extrapolation method applied to 4π(PC)−γ coincidence counting. The standardisation was performed by software coincidence counting—a digital method for primary activity measurement that simplifies the setting of optimal coincidence parameters. The γ-ray-energy window, characterised by identical gamma detection efficiency related to the sum of EC and to the sum of beta decay branches, was found. This setting ensured a linear and zero slope extrapolation curve. - Highlights: • Standardisation realised by extrapolation method applied to 4π(PC)−γ coincidence. • Digital method for optimal setting of coincidence parameters was used. • Result with total standard uncertainty of 0.74% was obtained

  12. More accurate thermal neutron coincidence counting technique

    International Nuclear Information System (INIS)

    Baron, N.

    1978-01-01

    Using passive thermal neutron coincidence counting techniques, the accuracy of nondestructive assays of fertile material can be improved significantly using a two-ring detector. It was shown how the use of a function of the coincidence count rate ring-ratio can provide a detector response rate that is independent of variations in neutron detection efficiency caused by varying sample moderation. Furthermore, the correction for multiplication caused by SF- and (α,n)-neutrons is shown to be separable into the product of a function of the effective mass of 240 Pu (plutonium correction) and a function of the (α,n) reaction probability (matrix correction). The matrix correction is described by a function of the singles count rate ring-ratio. This correction factor is empirically observed to be identical for any combination of PuO 2 powder and matrix materials SiO 2 and MgO because of the similar relation of the (α,n)-Q value and (α,n)-reaction cross section among these matrix nuclei. However the matrix correction expression is expected to be different for matrix materials such as Na, Al, and/or Li. Nevertheless, it should be recognized that for comparison measurements among samples of similar matrix content, it is expected that some function of the singles count rate ring-ratio can be defined to account for variations in the matrix correction due to differences in the intimacy of mixture among the samples. Furthermore the magnitude of this singles count rate ring-ratio serves to identify the contaminant generating the (α,n)-neutrons. Such information is useful in process control

  13. A generalized model for coincidence counting

    International Nuclear Information System (INIS)

    Lu, Ming-Shih; Teichmann, T.

    1992-01-01

    The aim of this paper is to provide a description of the multiplicative processes associated with coincidence counting techniques, for example in the NDA of plutonium bearing materials. The model elucidates both the physical processes and the underlying mathematical formalism in a relatively simple but comprehensive way. In particular, it includes the effect of absorption by impurities or poisons, as well as that of neutron leakage on a parallel basis to the treatment of induced fission itself. The work thus parallels and generalizes the methods of Boehnel of Hage and Cifarelli, and more recently of Yanjushkin. This paper introduces the concept of a dual probability generating function to account for both the basic physical multiplication phenomena, as well as the detection phenomena. The underlying approach extends the idea of a simple probability generating function, due to De Moivre. The basic mathematical background may be found, for example, in Feller 1966

  14. Neutron coincidence counting with digital signal processing

    International Nuclear Information System (INIS)

    Bagi, Janos; Dechamp, Luc; Dransart, Pascal; Dzbikowicz, Zdzislaw; Dufour, Jean-Luc; Holzleitner, Ludwig; Huszti, Joseph; Looman, Marc; Marin Ferrer, Montserrat; Lambert, Thierry; Peerani, Paolo; Rackham, Jamie; Swinhoe, Martyn; Tobin, Steve; Weber, Anne-Laure; Wilson, Mark

    2009-01-01

    Neutron coincidence counting is a widely adopted nondestructive assay (NDA) technique used in nuclear safeguards to measure the mass of nuclear material in samples. Nowadays, most neutron-counting systems are based on the original-shift-register technology, like the (ordinary or multiplicity) Shift-Register Analyser. The analogue signal from the He-3 tubes is processed by an amplifier/single channel analyser (SCA) producing a train of TTL pulses that are fed into an electronic unit that performs the time- correlation analysis. Following the suggestion of the main inspection authorities (IAEA, Euratom and the French Ministry of Industry), several research laboratories have started to study and develop prototypes of neutron-counting systems with PC-based processing. Collaboration in this field among JRC, IRSN and LANL has been established within the framework of the ESARDA-NDA working group. Joint testing campaigns have been performed in the JRC PERLA laboratory, using different equipment provided by the three partners. One area of development is the use of high-speed PCs and pulse acquisition electronics that provide a time stamp (LIST-Mode Acquisition) for every digital pulse. The time stamp data can be processed directly during acquisition or saved on a hard disk. The latter method has the advantage that measurement data can be analysed with different values for parameters like predelay and gate width, without repeating the acquisition. Other useful diagnostic information, such as die-away time and dead time, can also be extracted from this stored data. A second area is the development of 'virtual instruments.' These devices, in which the pulse-processing system can be embedded in the neutron counter itself and sends counting data to a PC, can give increased data-acquisition speeds. Either or both of these developments could give rise to the next generation of instrumentation for improved practical neutron-correlation measurements. The paper will describe the

  15. Standardization of {sup 241}Am by digital coincidence counting, liquid scintillation counting and defined solid angle counting

    Energy Technology Data Exchange (ETDEWEB)

    Balpardo, C., E-mail: balpardo@cae.cnea.gov.a [Laboratorio de Metrologia de Radioisotopos, CNEA, Buenos Aires (Argentina); Capoulat, M.E.; Rodrigues, D.; Arenillas, P. [Laboratorio de Metrologia de Radioisotopos, CNEA, Buenos Aires (Argentina)

    2010-07-15

    The nuclide {sup 241}Am decays by alpha emission to {sup 237}Np. Most of the decays (84.6%) populate the excited level of {sup 237}Np with energy of 59.54 keV. Digital coincidence counting was applied to standardize a solution of {sup 241}Am by alpha-gamma coincidence counting with efficiency extrapolation. Electronic discrimination was implemented with a pressurized proportional counter and the results were compared with two other independent techniques: Liquid scintillation counting using the logical sum of double coincidences in a TDCR array and defined solid angle counting taking into account activity inhomogeneity in the active deposit. The results show consistency between the three methods within a limit of a 0.3%. An ampoule of this solution will be sent to the International Reference System (SIR) during 2009. Uncertainties were analysed and compared in detail for the three applied methods.

  16. Fast coincidence counting with active inspection systems

    Science.gov (United States)

    Mullens, J. A.; Neal, J. S.; Hausladen, P. A.; Pozzi, S. A.; Mihalczo, J. T.

    2005-12-01

    This paper describes 2nd and 3rd order time coincidence distributions measurements with a GHz processor that synchronously samples 5 or 10 channels of data from radiation detectors near fissile material. On-line, time coincidence distributions are measured between detectors or between detectors and an external stimulating source. Detector-to-detector correlations are useful for passive measurements also. The processor also measures the number of times n pulses occur in a selectable time window and compares this multiplet distribution to a Poisson distribution as a method of determining the occurrence of fission. The detectors respond to radiation emitted in the fission process induced internally by inherent sources or by external sources such as LINACS, DT generators either pulsed or steady state with alpha detectors, etc. Data can be acquired from prompt emission during the source pulse, prompt emissions immediately after the source pulse, or delayed emissions between source pulses. These types of time coincidence measurements (occurring on the time scale of the fission chain multiplication processes for nuclear weapons grade U and Pu) are useful for determining the presence of these fissile materials and quantifying the amount, and are useful for counter terrorism and nuclear material control and accountability. This paper presents the results for a variety of measurements.

  17. Fast coincidence counting with active inspection systems

    International Nuclear Information System (INIS)

    Mullens, J.A.; Neal, J.S.; Hausladen, P.A.; Pozzi, S.A.; Mihalczo, J.T.

    2005-01-01

    This paper describes 2nd and 3rd order time coincidence distributions measurements with a GHz processor that synchronously samples 5 or 10 channels of data from radiation detectors near fissile material. On-line, time coincidence distributions are measured between detectors or between detectors and an external stimulating source. Detector-to-detector correlations are useful for passive measurements also. The processor also measures the number of times n pulses occur in a selectable time window and compares this multiplet distribution to a Poisson distribution as a method of determining the occurrence of fission. The detectors respond to radiation emitted in the fission process induced internally by inherent sources or by external sources such as LINACS, DT generators either pulsed or steady state with alpha detectors, etc. Data can be acquired from prompt emission during the source pulse, prompt emissions immediately after the source pulse, or delayed emissions between source pulses. These types of time coincidence measurements (occurring on the time scale of the fission chain multiplication processes for nuclear weapons grade U and Pu) are useful for determining the presence of these fissile materials and quantifying the amount, and are useful for counter terrorism and nuclear material control and accountability. This paper presents the results for a variety of measurements

  18. Coincidence-counting corrections for accidental coincidences, set dead time and intrinsic dead time

    International Nuclear Information System (INIS)

    Wyllie, H.A.

    1998-01-01

    An equation is derived for calculating the radioactivity of a source from the results of coincidence counting, taking into account dead-time losses and accidental coincidences. The corrections allow for the extension of the set dead time in the p channel by the intrinsic dead time. Experimental verification shows improvement over a previous equation. (author)

  19. Some target assay uncertainties for passive neutron coincidence counting

    International Nuclear Information System (INIS)

    Ensslin, N.; Langner, D.G.; Menlove, H.O.; Miller, M.C.; Russo, P.A.

    1990-01-01

    This paper provides some target assay uncertainties for passive neutron coincidence counting of plutonium metal, oxide, mixed oxide, and scrap and waste. The target values are based in part on past user experience and in part on the estimated results from new coincidence counting techniques that are under development. The paper summarizes assay error sources and the new coincidence techniques, and recommends the technique that is likely to yield the lowest assay uncertainty for a given material type. These target assay uncertainties are intended to be useful for NDA instrument selection and assay variance propagation studies for both new and existing facilities. 14 refs., 3 tabs

  20. High rate 4π β-γ coincidence counting system

    International Nuclear Information System (INIS)

    Johnson, L.O.; Gehrke, R.J.

    1978-01-01

    A high count rate 4π β-γ coincidence counting system for the determination of absolute disintegration rates of short half-life radionuclides is described. With this system the dead time per pulse is minimized by not stretching any pulses beyond the width necessary to satisfy overlap coincidence requirements. The equations used to correct for the β, γ, and coincidence channel dead times and for accidental coincidences are presented but not rigorously developed. Experimental results are presented for a decaying source of 56 Mn initially at 2 x 10 6 d/s and a set of 60 Co sources of accurately known source strengths varying from 10 3 to 2 x 10 6 d/s. A check of the accidental coincidence equation for the case of two independent sources with varying source strengths is presented

  1. The optimum choice of gate width for neutron coincidence counting

    Energy Technology Data Exchange (ETDEWEB)

    Croft, S., E-mail: crofts@ornl.gov [Safeguards and Security Technology (SST), Global Nuclear Security Technology Divisions, PO Box 2008, Building 5700, MS-6166, Oak Ridge, TN 37831-6166 (United States); Henzlova, D.; Favalli, A.; Hauck, D.K.; Santi, P.A. [Safeguards Science and Technology Group (NEN-1), Nuclear Engineering and Nonproliferation Division, MS-E540, Los Alamos, NM 87545 (United States)

    2014-11-11

    In the measurement field of international nuclear safeguards, passive neutron coincidence counting is used to quantify the spontaneous fission rate of certain special nuclear materials. The shift register autocorrelation analysis method is the most commonly used approach. However, the Feynman-Y technique, which is more commonly applied in reactor noise analysis, provides an alternative means to extract the correlation information from a pulse train. In this work we consider how to select the optimum gate width for each of these two time-correlation analysis techniques. The optimum is considered to be that which gives the lowest fractional precision on the net doublets rate. Our theoretical approach is approximate but is instructional in terms of revealing the key functional dependence. We show that in both cases the same performance figure of merit applies so that common design criteria apply to the neutron detector head. Our prediction is that near optimal results, suitable for most practical applications, can be obtained from both techniques using a common gate width setting. The estimated precision is also comparable in the two cases. The theoretical expressions are tested experimentally using {sup 252}Cf spontaneous fission sources measured in two thermal well counters representative of the type in common use by international inspectorates. Fast accidental sampling was the favored method of acquiring the Feynman-Y data. Our experimental study confirmed the basic functional dependences predicted although experimental results when available are preferred. With an appropriate gate setting Feynman-Y analysis provides an alternative to shift register analysis for safeguards applications which is opening up new avenues of data collection and data reduction to explore.

  2. High sensitivity neutron activation analysis using coincidence counting method

    International Nuclear Information System (INIS)

    Suzuki, Shogo; Okada, Yukiko; Hirai, Shoji

    1999-01-01

    Four kinds of standard samples such as river sediment (NIES CRM No.16), Typical Japanese Diet, otoliths and river water were irradiated by TRIGA-II (100 kW, 3.7x10 12 n cm -2 s -1 ) for 6 h. After irradiation and cooling, they were analyzed by the coincidence counting method and a conventional γ-ray spectrometry. Se, Ba and Hf were determined by 75 Se 265 keV, 131 Ba 496 keV and 181 Hf 482 keV. On the river sediment sample, Ba and Hf showed the same values by two methods, but Se value contained Ta by the conventional method, although the coincidence counting method could analyze Se. On Typical Japanese Diet and otoliths, Se could be determined by two methods and Ba and Hf determined by the coincidence counting method but not determined by the conventional method. Se value in the river water agreed with the authorization value. (S.Y.)

  3. Recent Advances in Digital Coincidence Counting for Radionuclide Metrology

    International Nuclear Information System (INIS)

    Keightley, John; Bobin, Christophe; Bouchard, Jacques; Capogni, Marco; Loreti, Stefano; Roteta, Miguel

    2013-06-01

    The radioactivity measurement techniques developed within the EURAMET EMRP 'MetroFission' Joint Research Project, were aimed at performing on-site activity measurements at the primary standard level (4πβ-γ coincidence counting) for a wide range of radionuclides utilizing recent advances in high-speed digital sampling and digital signal processing. The state-of-the-art technology employed within this project provides up to 14-bit digitizer systems operating with sampling rates in the order of 10 8 to 10 9 samples-per-second, incorporating on-board FPGA devices, which greatly enhances the application of digital signal processing for the implementation of digital coincidence counting. These devices when coupled to suitable analysis software, demonstrate a significant improvement in the provision of primary standards of radioactivity. This manuscript provides a description of the systems employed, along with recommendations regarding optimization of the digital sampling of signals from photo-multiplier tubes and pre-amplifiers and compare the benefits of 'off-line' versus 'on-line' 4πβ-γ digital coincidence counting systems. (authors)

  4. Monte Carlo calculations of the neutron coincidence gate utilisation factor for passive neutron coincidence counting

    CERN Document Server

    Bourva, L C A

    1999-01-01

    The general purpose neutron-photon-electron Monte Carlo N-Particle code, MCNP sup T sup M , has been used to simulate the neutronic characteristics of the on-site laboratory passive neutron coincidence counter to be installed, under Euratom Safeguards Directorate supervision, at the Sellafield reprocessing plant in Cumbria, UK. This detector is part of a series of nondestructive assay instruments to be installed for the accurate determination of the plutonium content of nuclear materials. The present work focuses on one aspect of this task, namely, the accurate calculation of the coincidence gate utilisation factor. This parameter is an important term in the interpretative model used to analyse the passive neutron coincidence count data acquired using pulse train deconvolution electronics based on the shift register technique. It accounts for the limited proportion of neutrons detected within the time interval for which the electronics gate is open. The Monte Carlo code MCF, presented in this work, represents...

  5. Monte Carlo calculations of the neutron coincidence gate utilisation factor for passive neutron coincidence counting

    International Nuclear Information System (INIS)

    Bourva, L.C.A.; Croft, S.

    1999-01-01

    The general purpose neutron-photon-electron Monte Carlo N-Particle code, MCNP TM , has been used to simulate the neutronic characteristics of the on-site laboratory passive neutron coincidence counter to be installed, under Euratom Safeguards Directorate supervision, at the Sellafield reprocessing plant in Cumbria, UK. This detector is part of a series of nondestructive assay instruments to be installed for the accurate determination of the plutonium content of nuclear materials. The present work focuses on one aspect of this task, namely, the accurate calculation of the coincidence gate utilisation factor. This parameter is an important term in the interpretative model used to analyse the passive neutron coincidence count data acquired using pulse train deconvolution electronics based on the shift register technique. It accounts for the limited proportion of neutrons detected within the time interval for which the electronics gate is open. The Monte Carlo code MCF, presented in this work, represents a new evaluation technique for the estimation of gate utilisation factors. It uses the die-away profile of a neutron coincidence chamber generated either by MCNP TM , or by other means, to simulate the neutron detection arrival time pattern originating from independent spontaneous fission events. A shift register simulation algorithm, embedded in the MCF code, then calculates the coincidence counts scored within the electronics gate. The gate utilisation factor is then deduced by dividing the coincidence counts obtained with that obtained in the same Monte Carlo run, but for an ideal detection system with a coincidence gate utilisation factor equal to unity. The MCF code has been benchmarked against analytical results calculated for both single and double exponential die-away profiles. These results are presented along with the development of the closed form algebraic expressions for the two cases. Results of this validity check showed very good agreement. On this

  6. First principle active neutron coincidence counting measurements of uranium oxide

    Energy Technology Data Exchange (ETDEWEB)

    Goddard, Braden, E-mail: goddard.braden@gmail.com [Nuclear Security Science and Policy Institute, Texas A and M University, College Station, Texas 77843 (United States); Charlton, William [Nuclear Security Science and Policy Institute, Texas A and M University, College Station, Texas 77843 (United States); Peerani, Paolo [European Commission, EC-JRC-ITU, Ispra (Italy)

    2014-03-01

    Uranium is present in most nuclear fuel cycle facilities ranging from uranium mines, enrichment plants, fuel fabrication facilities, nuclear reactors, and reprocessing plants. The isotopic, chemical, and geometric composition of uranium can vary significantly between these facilities, depending on the application and type of facility. Examples of this variation are: enrichments varying from depleted (∼0.2 wt% {sup 235}U) to high enriched (>20 wt% {sup 235}U); compositions consisting of U{sub 3}O{sub 8}, UO{sub 2}, UF{sub 6}, metallic, and ceramic forms; geometries ranging from plates, cans, and rods; and masses which can range from a 500 kg fuel assembly down to a few grams fuel pellet. Since {sup 235}U is a fissile material, it is routinely safeguarded in these facilities. Current techniques for quantifying the {sup 235}U mass in a sample include neutron coincidence counting. One of the main disadvantages of this technique is that it requires a known standard of representative geometry and composition for calibration, which opens up a pathway for potential erroneous declarations by the State and reduces the effectiveness of safeguards. In order to address this weakness, the authors have developed a neutron coincidence counting technique which uses the first principle point-model developed by Boehnel instead of the “known standard” method. This technique was primarily tested through simulations of 1000 g U{sub 3}O{sub 8} samples using the Monte Carlo N-Particle eXtended (MCNPX) code. The results of these simulations showed good agreement between the simulated and exact {sup 235}U sample masses.

  7. Sustaining IAEA Neutron Coincidence Counting: Past, Present and Future

    International Nuclear Information System (INIS)

    Longo, J.; Schaffer, K.M.; Nordquist, H.

    2015-01-01

    Los Alamos National Laboratory's IAEA Neutron Coincidence Counting (INCC) code is the standard tool for neutron coincidence counting measurements. INCC software and its' predecessors were originally implemented in the 1970s. The measurement and analysis techniques perfected in the code arise from many years of laboratory and field experience by nuclear engineers and physicists. Covering the full arc of INCC's lifecycle, we discuss the engineering approaches used for conception, original development, worldwide deployment of the stand-alone Windows application, more than a decade of sustained maintenance support, and our recent work to carry INCC successfully into future applications. We delve into the recent re-architecture of the INCC code base, an effort to create a maintainable and extensible architecture designed to preserve the existing INCC code base while adding support for new analyzes and instruments (e.g., List Mode PTR-32 and the List Mode Multiplicity Module). INCC now consists of separate modules implementing attended instrumentation control, data file processing, statistical and Pu mass calculation and analyzes, list mode counting and analyzes, reporting functions, and a database support library. Separating functional capabilities in this architecture enables better testing, isolates development risk and enables the use of INCC features in other software systems. We discuss our approach to handling divergent data and protocol support as a result of this re-architecture. INCC has complex testing requirements; we show how the testing effort was reduced by breaking the software into separate modules. This new architecture enables integration of INCC analysis into the IAEA's new Integrated Review and Analysis Programme (iRAP) data review system. iRAP is based on the respected Euratom Comprehensive Review Inspector Software Package (CRISP) software framework, and is expected to be the future data review system for IAEA and Euratom

  8. Standardization of Ga-68 by coincidence measurements, liquid scintillation counting and 4πγ counting.

    Science.gov (United States)

    Roteta, Miguel; Peyres, Virginia; Rodríguez Barquero, Leonor; García-Toraño, Eduardo; Arenillas, Pablo; Balpardo, Christian; Rodrígues, Darío; Llovera, Roberto

    2012-09-01

    The radionuclide (68)Ga is one of the few positron emitters that can be prepared in-house without the use of a cyclotron. It disintegrates to the ground state of (68)Zn partially by positron emission (89.1%) with a maximum energy of 1899.1 keV, and partially by electron capture (10.9%). This nuclide has been standardized in the frame of a cooperation project between the Radionuclide Metrology laboratories from CIEMAT (Spain) and CNEA (Argentina). Measurements involved several techniques: 4πβ-γ coincidences, integral gamma counting and Liquid Scintillation Counting using the triple to double coincidence ratio and the CIEMAT/NIST methods. Given the short half-life of the radionuclide assayed, a direct comparison between results from both laboratories was excluded and a comparison of experimental efficiencies of similar NaI detectors was used instead. Copyright © 2012 Elsevier Ltd. All rights reserved.

  9. Coincidence and noncoincidence counting (81Rb and 43K): a comparative study

    International Nuclear Information System (INIS)

    Ikeda, S.; Duken, H.; Tillmanns, H.; Bing, R.J.

    1975-01-01

    The accuracy of imaging and resolution obtained with 81 Rb and 43 K using coincidence and noncoincidence counting was compared. Phantoms and isolated infarcted dog hearts were used. The results clearly show the superiority of coincidence counting with a resolution of 0.5 cm. Noncoincidence counting failed to reveal even sizable defects in the radioactive source. (U.S.)

  10. Standardization of Ga-68 by coincidence measurements, liquid scintillation counting and 4πγ counting

    International Nuclear Information System (INIS)

    Roteta, Miguel; Peyres, Virginia; Rodríguez Barquero, Leonor; García-Toraño, Eduardo; Arenillas, Pablo; Balpardo, Christian; Rodrígues, Darío; Llovera, Roberto

    2012-01-01

    The radionuclide 68 Ga is one of the few positron emitters that can be prepared in-house without the use of a cyclotron. It disintegrates to the ground state of 68 Zn partially by positron emission (89.1%) with a maximum energy of 1899.1 keV, and partially by electron capture (10.9%). This nuclide has been standardized in the frame of a cooperation project between the Radionuclide Metrology laboratories from CIEMAT (Spain) and CNEA (Argentina). Measurements involved several techniques: 4πβ−γ coincidences, integral gamma counting and Liquid Scintillation Counting using the triple to double coincidence ratio and the CIEMAT/NIST methods. Given the short half-life of the radionuclide assayed, a direct comparison between results from both laboratories was excluded and a comparison of experimental efficiencies of similar NaI detectors was used instead. - Highlights: ► We standardized the positron emitter Ga-68 in a bilateral cooperation. ► We used several techniques, as coincidence, integral gamma and liquid scintillation. ► An efficiency comparison replaced a direct comparison of reference materials.

  11. A new approach to beta-gamma coincidence counting. Advance report on the Samar electronic system

    International Nuclear Information System (INIS)

    Carlos, J. E. de; Granados, C. E.

    1972-01-01

    In 4π β-γ coincidence measurements, precision on the evaluation of coincidence counting losses is made difficult because of complex overlapping effects between theβ--and γ-side dead times due to pre cursive counted events. In this context the SAMAR electronic system is aimed to give a precise way of automatic counting and reduce the need for calculated corrections. This report describes its configuration and basic features. The SAMAR has been conceived in such a manner that both beta and gamma chains are sharing a common and non extending dead-time which is simultaneously applied to both channels. The shared dead time is made to be the only one inserted throughout the chains. Overlapping effects vanish and the three counting channels have identical transmission ratios. A new dead-time circuit based on fast linear gates as blocking elements has been developed. Application of the two-oscillator Muller's method evidences a fully non-extending character. Automatism is implemented by using a live timer corrective channel controlling the counting scalers. (Author) 21 refs

  12. Metrology and statistical analysis for the precise standardisation of cobalt-60 by 4πβ-γ coincidence counting

    International Nuclear Information System (INIS)

    Buckman, S.M.

    1995-03-01

    The major part of the thesis is devoted to the theoretical development of a comprehensive PC-based statistical package for the analysis of data from coincidence-counting experiments. This analysis is applied to primary standardizations of Co performed in Australia and Japan. The Australian standardisation, the accuracy of which is confirmed through international comparison, is used to re-calibrate the ionisation chamber. Both Australian and Japanese coincidence-counting systems are interfaced to personal computers to enable replicated sets of measurements to be made under computer control. Further research to confirm the validity of the statistical model includes an experimental investigation into the non-Poisson behaviour of radiation detectors due to the effect of deadtime. Experimental investigation is conducted to determine which areas are most likely to limit the ultimate accuracy achievable with coincidence counting. The thesis concludes by discussing the possibilities of digital coincidence counting and outlines the design of a prototype system presently under development. The accuracy of the Australian standardisation is confirmed by international comparison. From this result a more accurate Co calibration is obtained for the Australian working standard. Based on the work of this thesis, uncertainties in coincidence counting experiments can be better handled with resulting improvements in measurement reliability. The concept and benefits of digital coincidence counting are discussed and a proposed design is given for such a system. All of the data and software associated with this thesis is provided on computer discs. 237 refs., figs., tabs

  13. The IAEA neutron coincidence counting (INCC) and the DEMING least-squares fitting programs

    International Nuclear Information System (INIS)

    Krick, M.S.; Harker, W.C.; Rinard, P.M.; Wenz, T.R.; Lewis, W.; Pham, P.; Ridder, P. de

    1998-01-01

    Two computer programs are described: (1) the INCC (IAEA or International Neutron Coincidence Counting) program and (2) the DEMING curve-fitting program. The INCC program is an IAEA version of the Los Alamos NCC (Neutron Coincidence Counting) code. The DEMING program is an upgrade of earlier Windows reg-sign and DOS codes with the same name. The versions described are INCC 3.00 and DEMING 1.11. The INCC and DEMING codes provide inspectors with the software support needed to perform calibration and verification measurements with all of the neutron coincidence counting systems used in IAEA inspections for the nondestructive assay of plutonium and uranium

  14. Calibration of nuclides by gamma-gamma sum peak coincidence counting

    International Nuclear Information System (INIS)

    Guevara, E.A.

    1986-01-01

    The feasibility of extending sum peak coincidence counting to the direct calibration of gamma-ray emitters having particular decay schemes was investigated, also checkings of the measurement accuracy, by comparing with more precise beta-gamma coincidence counting have been performed. New theoretical studies and experiments were developed, demonstrating the reliability of the procedure. Uncertainties of less than one percent were obtained when certain radioactive sources were measured. The application of the procedure to 60 Co, 22 Na, 47 Ca and 148 Pm was studied. Theoretical bases of sum peak coincidence counting were set in order to extend it as an alternative method for absolute activity determination. In this respect, theoretical studies were performed for positive and negative beta decay, and electron capture, either accompanied or unaccompanied by coincident gamma rays. They include decay schemes containing up to three daughter nuclide excited levels, for different geometrical configurations. Equations are proposed for a possible generalization of the procedure. (M.E.L.) [es

  15. Standardization of I-125 solution by extrapolation of an efficiency wave obtained by coincidence X-(X-γ) counting method

    International Nuclear Information System (INIS)

    Iwahara, A.

    1989-01-01

    The activity concentration of 125 I was determined by X-(X-α) coincidence counting method and efficiency extrapolation curve. The measurement system consists of 2 thin NaI(T1) scintillation detectors which are horizontally movable on a track. The efficiency curve is obtained by symmetricaly changing the distance between the source and the detectors and the activity is determined by applying a linear efficiency extrapolation curve. All sum-coincidence events are included between 10 and 100 KeV window counting and the main source of uncertainty is coming from poor counting statistic around zero efficiency. The consistence of results with other methods shows that this technique can be applied to photon cascade emitters and are not discriminating by the detectors. It has been also determined the 35,5 KeV gamma-ray emission probability of 125 I by using a Gamma-X type high purity germanium detector. (author) [pt

  16. Uranium mass and neutron multiplication factor estimates from time-correlation coincidence counts

    Energy Technology Data Exchange (ETDEWEB)

    Xie, Wenxiong [China Academy of Engineering Physics, Center for Strategic Studies, Beijing 100088 (China); Li, Jiansheng [China Academy of Engineering Physics, Institute of Nuclear Physics and Chemistry, Mianyang 621900 (China); Zhu, Jianyu [China Academy of Engineering Physics, Center for Strategic Studies, Beijing 100088 (China)

    2015-10-11

    Time-correlation coincidence counts of neutrons are an important means to measure attributes of nuclear material. The main deficiency in the analysis is that an attribute of an unknown component can only be assessed by comparing it with similar known components. There is a lack of a universal method of measurement suitable for the different attributes of the components. This paper presents a new method that uses universal relations to estimate the mass and neutron multiplication factor of any uranium component with known enrichment. Based on numerical simulations and analyses of 64 highly enriched uranium components with different thicknesses and average radii, the relations between mass, multiplication and coincidence spectral features have been obtained by linear regression analysis. To examine the validity of the method in estimating the mass of uranium components with different sizes, shapes, enrichment, and shielding, the features of time-correlation coincidence-count spectra for other objects with similar attributes are simulated. Most of the masses and multiplications for these objects could also be derived by the formulation. Experimental measurements of highly enriched uranium castings have also been used to verify the formulation. The results show that for a well-designed time-dependent coincidence-count measuring system of a uranium attribute, there are a set of relations dependent on the uranium enrichment by which the mass and multiplication of the measured uranium components of any shape and size can be estimated from the features of the source-detector coincidence-count spectrum.

  17. Use of sum-peak and coincidence counting methods for activity standardization of {sup 22}Na

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira, E.M. de, E-mail: estela@ird.gov.br [Laboratorio Nacional de Metrologia das Radiacoes Ionizantes (LNMRI/IRD/CNEN), Av. Salvador Allende, s/n, Recreio, CEP 22780-160 Rio de Janeiro (Brazil); Iwahara, A.; Poledna, R. [Laboratorio Nacional de Metrologia das Radiacoes Ionizantes (LNMRI/IRD/CNEN), Av. Salvador Allende, s/n, Recreio, CEP 22780-160 Rio de Janeiro (Brazil); Silva, M.A.L. da [Coordenacao Geral de Instalacoes Nucleares/Comissao Nacional de Energia Nuclear, R. Gal. Severiano, 90 - Botafogo, CEP 22290-901 Rio de Janeiro (Brazil); Tauhata, L. [Fundacao Carlos Chagas Filho de Amparo a Pesquisa do Estado do Rio de Janeiro (FAPERJ), Av. Erasmo Braga, 118-6 Degree-Sign andar, CEP 20020-000 Centro, Rio de Janeiro (Brazil); Delgado, J.U. [Laboratorio Nacional de Metrologia das Radiacoes Ionizantes (LNMRI/IRD/CNEN), Av. Salvador Allende, s/n, Recreio, CEP 22780-160 Rio de Janeiro (Brazil); Lopes, R.T. [Laboratorio de Instrumentacao Nuclear (LIN/PEN/COPPE/UFRJ), Caixa Postal 68509, CEP 21945-970 Rio de Janeiro (Brazil)

    2012-09-21

    A solution containing the positron emitter {sup 22}Na has been absolutely standardized using the 4{pi}{beta}-{gamma} coincidence counting method and the sum-peak spectrometry counting method. In the 4{pi}{beta}-{gamma} coincidence method two ways for the activity concentration measurements were used: gating on the 1275 keV photopeak and on the 1786 keV sum-peak where the knowledge of the {beta}{sup +}-branching ratio is required. In the sum-peak method the measurements were carried out using three experimental arrangements: the first composed by a well type 5 in. Multiplication-Sign 5 in. NaI(Tl) scintillation crystal, the second by a 3 in. Multiplication-Sign 3 in. NaI(Tl) scintillation crystal placed on the top of the first, resulting in a 4{pi} counting geometry and the third arrangement is a high purity coaxial germanium detector. The results that are obtained by these two methods are compatible within the standard uncertainty values with a coverage factor of k=2 ({approx}95% of the confidence level). This means that the sum-peak counting with its more simple experimental setup than the complex coincidence 4{pi}{beta}-{gamma} counting system gives consistent results for the activity standardization of {sup 22}Na with smaller uncertainties. Besides, the time period involved to attain the result of the standardization was quite shorter than the coincidence measurements used in this work.

  18. Feynman variance-to-mean in the context of passive neutron coincidence counting

    Energy Technology Data Exchange (ETDEWEB)

    Croft, S., E-mail: scroft@lanl.gov [Los Alamos National Laboratory, PO Box 1663, Los Alamos, NM 87545 (United States); Favalli, A.; Hauck, D.K.; Henzlova, D.; Santi, P.A. [Los Alamos National Laboratory, PO Box 1663, Los Alamos, NM 87545 (United States)

    2012-09-11

    Passive Neutron Coincidence Counting (PNCC) based on shift register autocorrelation time analysis of the detected neutron pulse train is an important Nondestructive Assay (NDA) method. It is used extensively in the quantification of plutonium and other spontaneously fissile materials for purposes of nuclear materials accountancy. In addition to the totals count rate, which is also referred to as the singles, gross or trigger rate, a quantity known as the reals coincidence rate, also called the pairs or doubles, is obtained from the difference between the measured neutron multiplicities in two measurement gates triggered by the incoming events on the pulse train. The reals rate is a measure of the number of time correlated pairs present on the pulse train and this can be related to the fission rates (and hence material mass) since fissions emit neutrons in bursts which are also detected in characteristic clusters. A closely related measurement objective is the determination of the reactivity of systems as they approach criticality. In this field an alternative autocorrelation signature is popular, the so called Feynman variance-to-mean technique which makes use of the multiplicity histogram formed the periodic, or clock-triggered opening of a coincidence gate. Workers in these two application areas share common challenges and improvement opportunities but are often separated by tradition, problem focus and technical language. The purpose of this paper is to recognize the close link between the Feynman variance-to-mean metric and traditional PNCC using shift register logic applied to correlated pulse trains. We, show using relationships for the late-gate (or accidentals) histogram recorded using a multiplicity shift register, how the Feynman Y-statistic, defined as the excess variance-to-mean ratio, can be expressed in terms of the singles and doubles rates familiar to the safeguards and waste assay communities. These two specialisms now have a direct bridge between

  19. Moisture corrections in neutron coincidence counting of PuO2

    International Nuclear Information System (INIS)

    Stewart, J.E.; Menlove, H.O.

    1987-01-01

    Passive neutron coincidence counting is capable of 1% assay accuracy for pure, well-characterized PuO 2 samples that contain plutonium masses from a few tens of grams to several kilograms. Moisture in the sample can significantly bias the assay high by changing the (α,n) neutron production, the sample multiplication, and the detection efficiency. Monte Carlo calculations and an analytical model of coincidence counting have been used to quantify the individual and cumulative effects of moisture biases for two PuO 2 sample sizes and a range of moisture levels from 0 to 9 wt %. Results of the calculations suggest a simple correction procedure for moisture bias that is effective from 0 to 3 wt % H 2 O. The procedure requires that the moisture level in the sample be known before the coincidence measurement

  20. A 15 channel 2- and 3-fold coincidence counting system for radioactivity standardization

    International Nuclear Information System (INIS)

    Simpson, B.R.S.; Meyer, B.R.; Raave, D.A.

    1986-01-01

    The 4π β-γ liquid scintillation coincidence counting system which is used at the National Accelerator Centre for standardizing radioisotopes, has been extended to allow for up to fifteen data points to be measured simultaneously by introducing a 15-fold coincidence unit and a 32-channel scaler into the system. A new control / data acquisition computer program has been written and its operation explained in detail. The advantages of the new system are discussed, and the activity of a 139 Ce source as measured by the new system and the old 3-fold system is compared

  1. Passive neutron coincidence counting with plastic scintillators for the characterization of radioactive waste drums

    Energy Technology Data Exchange (ETDEWEB)

    Deyglun, C.; Simony, B.; Perot, B.; Carasco, C. [CEA, DEN, Cadarache, Nuclear Measurement Laboratory, F-13108 Saint-Paul-lez-Durance (France); Saurel, N.; Colas, S. [CEA, DAM, Valduc, F-21120 Is-sur-Tille (France); Collot, J. [Laboratoire de Physique Subatomique et de Cosmologie, Universite Grenoble Alpes, CNRS/IN2P3, Grenoble (France)

    2015-07-01

    The quantification of radioactive material is essential in the fields of safeguards, criticality control of nuclear processes, dismantling of nuclear facilities and components, or radioactive waste characterization. The Nuclear Measurement Laboratory (LMN) of CEA is involved in the development of time-correlated neutron detection techniques using plastic scintillators. Usually, 3He proportional counters are used for passive neutron coincidence counting owing to their high thermal neutron capture efficiency and gamma insensitivity. However, the global {sup 3}He shortage in the past few years has made these detectors extremely expensive. In addition, contrary to {sup 3}He counters for which a few tens of microseconds are needed to thermalize fast neutrons, in view to maximize the {sup 3}He(n,p){sup 3}H capture cross section, plastic scintillators are based on elastic scattering and therefore the light signal is formed within a few nanoseconds, correlated pulses being detected within a few dozen- or hundred nanoseconds. This time span reflects fission particles time of flight, which allows reducing accordingly the duration of the coincidence gate and thus the rate of random coincidences, which may totally blind fission coincidences when using {sup 3}He counters in case of a high (α,n) reaction rate. However, plastic scintillators are very sensitive to gamma rays, requiring the use of a thick metallic shield to reduce the corresponding background. Cross talk between detectors is also a major issue, which consists on the detection of one particle by several detectors due to elastic or inelastic scattering, leading to true but undesired coincidences. Data analysis algorithms are tested to minimize cross-talk in simultaneously activated detectors. The distinction between useful fission coincidences and the correlated background due to cross-talk, (α,n) and induced (n,2n) or (n,n'γ) reactions, is achieved by measuring 3-fold coincidences. The performances of a

  2. Pile-up correction for coincidence counting using a CAEN 1724 digitizer

    Energy Technology Data Exchange (ETDEWEB)

    Ribeiro Junior, Iberê S.; Zahn, Guilherme S.; Genezini, Frederico A., E-mail: gzahn@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2017-07-01

    In conventional gamma-ray spectrometry, the probability of pile-up effects is considered to be proportional to the dead-time, and is usually neglected for low dead-times (below 4-5%). In gamma-gamma coincidence spectrometry, though, while the dead time takes into account only events that are actually digitized, the pile-up effects are proportional to the actual gamma-ray detection rate in each detector, not only to the ones that trigger the coincidence gate. Thus, the pile-up corrections may not be so easy to assess as in single spectrometry systems. In this work, a system composed of two HPGe detectors coupled to a CAEN v1724 digitizer is studied. A 3kBq {sup 60}Co source was analyzed, both alone and in the presence of other radioactive sources ({sup 137}Cs, {sup 133}Ba and {sup 152}Eu), and the resulting coincidence peak areas were compared to assess the effectiveness of two distinct corrections: a simple normalization by the live time of acquisition and the normalization by the count rate obtained using a pulse generator. The results obtained stress the need to use the pulse generator in this specific setup in order to get accurate results. (author)

  3. Standardization of iodine-129 by the TDCR liquid scintillation method and 4π β-γ coincidence counting

    Science.gov (United States)

    Cassette, P.; Bouchard, J.; Chauvenet, B.

    1994-01-01

    Iodine-129 is a long-lived fission product, with physical and chemical properties that make it a good candidate for evaluating the environmental impact of the nuclear energy fuel cycle. To avoid solid source preparation problems, liquid scintillation has been used to standardize this nuclide for a EUROMET intercomparison. Two methods were used to measure the iodine-129 activity: triple-to-double-coincidence ratio liquid scintillation counting and 4π β-γ coincidence counting; the results are in good agreement.

  4. A Monte Carlo Model for Neutron Coincidence Counting with Fast Organic Liquid Scintillation Detectors

    International Nuclear Information System (INIS)

    Gamage, Kelum A.A.; Joyce, Malcolm J.; Cave, Frank D.

    2013-06-01

    Neutron coincidence counting is an established, nondestructive method for the qualitative and quantitative analysis of nuclear materials. Several even-numbered nuclei of the actinide isotopes, and especially even-numbered plutonium isotopes, undergo spontaneous fission, resulting in the emission of neutrons which are correlated in time. The characteristics of this i.e. the multiplicity can be used to identify each isotope in question. Similarly, the corresponding characteristics of isotopes that are susceptible to stimulated fission are somewhat isotope-related, and also dependent on the energy of the incident neutron that stimulates the fission event, and this can hence be used to identify and quantify isotopes also. Most of the neutron coincidence counters currently used are based on 3 He gas tubes. In the 3 He-filled gas proportional-counter, the (n, p) reaction is largely responsible for the detection of slow neutrons and hence neutrons have to be slowed down to thermal energies. As a result, moderator and shielding materials are essential components of many systems designed to assess quantities of fissile materials. The use of a moderator, however, extends the die-away time of the detector necessitating a larger coincidence window and, further, 3 He is now in short supply and expensive. In this paper, a simulation based on the Monte Carlo method is described which has been performed using MCNPX 2.6.0, to model the geometry of a sector-shaped liquid scintillation detector in response to coincident neutron events. The detection of neutrons from a mixed-oxide (MOX) fuel pellet using an organic liquid scintillator has been simulated for different thicknesses of scintillators. In this new neutron detector, a layer of lead has been used to reduce the gamma-ray fluence reaching the scintillator. The effect of lead for neutron detection has also been estimated by considering different thicknesses of lead layers. (authors)

  5. Performance of coincidence-based PSD on LiF/ZnS Detectors for Multiplicity Counting

    Energy Technology Data Exchange (ETDEWEB)

    Robinson, Sean M.; Stave, Sean C.; Lintereur, Azaree; Siciliano, Edward R.; Cowles, Christian C.; Kouzes, Richard T.; Behling, Richard S.

    2016-10-06

    Abstract: Mass accountancy measurement is a nuclear nonproliferation application which utilizes coincidence and multiplicity counters to verify special nuclear material declarations. With a well-designed and efficient detector system, several relevant parameters of the material can be verified simultaneously. 6LiF/ZnS scintillating sheets may be used for this purpose due to a combination of high efficiency and short die-away times in systems designed with this material, but involve choices of detector geometry and exact material composition (e.g., the addition of Ni-quenching in the material) that must be optimized for the application. Multiplicity counting for verification of declared nuclear fuel mass involves neutron detection in conditions where several neutrons arrive in a short time window, with confounding gamma rays. This paper considers coincidence-based Pulse-Shape Discrimination (PSD) techniques developed to work under conditions of high pileup, and the performance of these algorithms with different detection materials. Simulated and real data from modern LiF/ZnS scintillator systems are evaluated with these techniques and the relationship between the performance under pileup and material characteristics (e.g., neutron peak width and total light collection efficiency) are determined, to allow for an optimal choice of detector and material.

  6. Correction for variable moderation and multiplication effects associated with thermal neutron coincidence counting

    International Nuclear Information System (INIS)

    Baron, N.

    1978-01-01

    A correction is described for multiplication and moderation when doing passive thermal neutron coincidence counting nondestructive assay measurements on powder samples of PuO 2 mixed arbitrarily with MgO, SiO 2 , and moderating material. The multiplication correction expression is shown to be approximately separable into the product of two independent terms; F/sub Pu/ which depends on the mass of 240 Pu, and F/sub αn/ which depends on properties of the matrix material. Necessary assumptions for separability are (1) isotopic abundances are constant, and (2) fission cross sections are independent of incident neutron energy: both of which are reasonable for the 8% 240 Pu powder samples considered here. Furthermore since all prompt fission neutrons are expected to have nearly the same energy distributions, variations among different samples can be due only to the moderating properties of the samples. Relative energy distributions are provided by a thermal neutron well counter having two concentric rings of 3 He proportional counters placed symmetrically about the well. Measured outer-to-inner ring ratios raised to an empirically determined power for coincidences, (N/sup I//N/sup O/)/sup Z/, and singles, (T/sup O//T/sup I/)/sup delta/, provide corrections for moderation and F/sub αn/ respectively, and F/sub Pu/ is approximated by M 240 /sup X//M 240 . The exponents are calibration constants determined by a least squares fitting procedure using standards' data. System calibration is greatly simplified using the separability principle. Once appropriate models are established for F/sub Pu/ and F/sub αn/, only a few standards are necessary to determine the calibration constants associated with these terms. Since F/sub Pu/ is expressed as a function of M 240 , correction for multiplication in a subsequent assay demands only a measurement of F/sub αn/

  7. Determination of trace elements in scallop and fish otolith by instrumental neutron activation analysis using anti-coincidence and coincidence counting methods

    International Nuclear Information System (INIS)

    Suzuki, Shogo; Okada, Yukiko; Hirai, Shoji

    2005-01-01

    Trace element concentrations in scallop reference material and fish otolith certified reference materials prepared at the National Institute for Environmental Studies (NIES) of Japan were determined by instrumental neutron activation analysis (INAA). Nine aliquots of scallop sample (ca. 252∼507 mg) and five aliquots of fish otolith sample (ca. 502 ∼ 988 mg) and comparative standards were irradiated for a short time (10 s) at a thermal neutron flux of 1.5 x 10 12 n cm -2 s -1 (pneumatic transfer) and for a long time (6 h) at a thermal neutron flux of 3.7 x 10 12 n cm -2 s -1 (central thimble) in the Rikkyo University Research Reactor (100 kW). The irradiated samples were measured by conventional γ-ray spectrometry using a coaxial Ge detector, and by anti-coincidence and coincidence γ-ray spectrometry with a coaxial Ge detector and a well-type NaI (Tl) detector to determine as many trace elements as possible with high sensitivity. The concentrations of 34 elements of the NIES No.15 scallop reference material and 16 elements of the NIES No.22 fish otolith CRM were determined. Using the coincidence counting method to determine Se, Ba and Hf, the lower limit of the determination was improved by 2 times compared with the conventional counting method. (author)

  8. Application of the coincidence counting technique to DD neutron spectrometry data at the NIF, OMEGA, and Z

    Energy Technology Data Exchange (ETDEWEB)

    Lahmann, B., E-mail: lahmann@mit.edu; Milanese, L. M.; Han, W.; Gatu Johnson, M.; Séguin, F. H.; Frenje, J. A.; Petrasso, R. D. [Massachusetts Institute of Technology, Cambridge, Massachusetts 02139 (United States); Hahn, K. D.; Jones, B. [Sandia National Laboratory, Albuquerque, New Mexico 87123 (United States)

    2016-11-15

    A compact neutron spectrometer, based on a CH foil for the production of recoil protons and CR-39 detection, is being developed for the measurements of the DD-neutron spectrum at the NIF, OMEGA, and Z facilities. As a CR-39 detector will be used in the spectrometer, the principal sources of background are neutron-induced tracks and intrinsic tracks (defects in the CR-39). To reject the background to the required level for measurements of the down-scattered and primary DD-neutron components in the spectrum, the Coincidence Counting Technique (CCT) must be applied to the data. Using a piece of CR-39 exposed to 2.5-MeV protons at the MIT HEDP accelerator facility and DD-neutrons at Z, a significant improvement of a DD-neutron signal-to-background level has been demonstrated for the first time using the CCT. These results are in excellent agreement with previous work applied to DT neutrons.

  9. Application of the coincidence counting technique to DD neutron spectrometry data at the NIF, OMEGA, and Z

    International Nuclear Information System (INIS)

    Lahmann, B.; Milanese, L. M.; Han, W.; Gatu Johnson, M.; Séguin, F. H.; Frenje, J. A.; Petrasso, R. D.; Hahn, K. D.; Jones, B.

    2016-01-01

    A compact neutron spectrometer, based on a CH foil for the production of recoil protons and CR-39 detection, is being developed for the measurements of the DD-neutron spectrum at the NIF, OMEGA, and Z facilities. As a CR-39 detector will be used in the spectrometer, the principal sources of background are neutron-induced tracks and intrinsic tracks (defects in the CR-39). To reject the background to the required level for measurements of the down-scattered and primary DD-neutron components in the spectrum, the Coincidence Counting Technique (CCT) must be applied to the data. Using a piece of CR-39 exposed to 2.5-MeV protons at the MIT HEDP accelerator facility and DD-neutrons at Z, a significant improvement of a DD-neutron signal-to-background level has been demonstrated for the first time using the CCT. These results are in excellent agreement with previous work applied to DT neutrons.

  10. Application of the coincidence counting technique to DD neutron spectrometry data at the NIF, OMEGA, and Z.

    Science.gov (United States)

    Lahmann, B; Milanese, L M; Han, W; Gatu Johnson, M; Séguin, F H; Frenje, J A; Petrasso, R D; Hahn, K D; Jones, B

    2016-11-01

    A compact neutron spectrometer, based on a CH foil for the production of recoil protons and CR-39 detection, is being developed for the measurements of the DD-neutron spectrum at the NIF, OMEGA, and Z facilities. As a CR-39 detector will be used in the spectrometer, the principal sources of background are neutron-induced tracks and intrinsic tracks (defects in the CR-39). To reject the background to the required level for measurements of the down-scattered and primary DD-neutron components in the spectrum, the Coincidence Counting Technique (CCT) must be applied to the data. Using a piece of CR-39 exposed to 2.5-MeV protons at the MIT HEDP accelerator facility and DD-neutrons at Z, a significant improvement of a DD-neutron signal-to-background level has been demonstrated for the first time using the CCT. These results are in excellent agreement with previous work applied to DT neutrons.

  11. A new approach to beta-gamma coincidence counting. Advance report on the Samar electronic system; Informe preliminar del sistema Samar sistema automatico de medidas absolutas de Radionucleidos

    Energy Technology Data Exchange (ETDEWEB)

    Carlos, J E. de; Granados, C E

    1972-07-01

    In 4{pi} {beta}-{gamma} coincidence measurements, precision on the evaluation of coincidence counting losses is made difficult because of complex overlapping effects between the{beta}--and {gamma}-side dead times due to pre cursive counted events. In this context the SAMAR electronic system is aimed to give a precise way of automatic counting and reduce the need for calculated corrections. This report describes its configuration and basic features. The SAMAR has been conceived in such a manner that both beta and gamma chains are sharing a common and non extending dead-time which is simultaneously applied to both channels. The shared dead time is made to be the only one inserted throughout the chains. Overlapping effects vanish and the three counting channels have identical transmission ratios. A new dead-time circuit based on fast linear gates as blocking elements has been developed. Application of the two-oscillator Muller's method evidences a fully non-extending character. Automatism is implemented by using a live timer corrective channel controlling the counting scalers. (Author) 21 refs.

  12. A new approach to beta-gamma coincidence counting. Advance report on the Samar electronic system; Informe preliminar del sistema Samar sistema automatico de medidas absolutas de Radionucleidos

    Energy Technology Data Exchange (ETDEWEB)

    Carlos, J. E. de; Granados, C. E.

    1972-07-01

    In 4{pi} {beta}-{gamma} coincidence measurements, precision on the evaluation of coincidence counting losses is made difficult because of complex overlapping effects between the{beta}--and {gamma}-side dead times due to pre cursive counted events. In this context the SAMAR electronic system is aimed to give a precise way of automatic counting and reduce the need for calculated corrections. This report describes its configuration and basic features. The SAMAR has been conceived in such a manner that both beta and gamma chains are sharing a common and non extending dead-time which is simultaneously applied to both channels. The shared dead time is made to be the only one inserted throughout the chains. Overlapping effects vanish and the three counting channels have identical transmission ratios. A new dead-time circuit based on fast linear gates as blocking elements has been developed. Application of the two-oscillator Muller's method evidences a fully non-extending character. Automatism is implemented by using a live timer corrective channel controlling the counting scalers. (Author) 21 refs.

  13. Applied categorical and count data analysis

    CERN Document Server

    Tang, Wan; Tu, Xin M

    2012-01-01

    Introduction Discrete Outcomes Data Source Outline of the BookReview of Key Statistical ResultsSoftwareContingency Tables Inference for One-Way Frequency TableInference for 2 x 2 TableInference for 2 x r TablesInference for s x r TableMeasures of AssociationSets of Contingency Tables Confounding Effects Sets of 2 x 2 TablesSets of s x r TablesRegression Models for Categorical Response Logistic Regression for Binary ResponseInference about Model ParametersGoodness of FitGeneralized Linear ModelsRegression Models for Polytomous ResponseRegression Models for Count Response Poisson Regression Mode

  14. Study and development of a spectrometer with Compton suppression and gamma coincidence counting

    International Nuclear Information System (INIS)

    Masse, D.

    1990-10-01

    This paper presents the characteristics of a spectrometer consisting of a Ge detector surrounded by a NaI(T1) detector that can operate in Compton-suppression and gamma-gamma coincidence modes. The criteria that led to this measurement configuration are discussed and the spectrometer performances are shown for 60 Co and 137 Cs gamma-ray sources. The results for the measurement of 189 Ir (Compton suppression) and for the measurement of 101 Rh (gamma-gamma coincidence) in the presence of other radioisotopes are given. 83 Rb and 105 Ag isotopes are also measured with this spectrometer [fr

  15. Primary standardization of {sup 152}Eu by 4πβ(LS) - γ (NaI) coincidence counting and CIEMAT-NIST method

    Energy Technology Data Exchange (ETDEWEB)

    Ruzzarin, A., E-mail: aruzzarin@nuclear.ufrj.br [Coordenacao de Pos-Graduacao e Pesquisa de Engenharia (LIN/PEN/COPPE/UFRJ), Rio de Janeiro, RJ (Brazil). Lab. de Instrumentação Nuclear; Cruz, P.A.L. da; Ferreira Filho, A.L.; Iwahara, A. [Instituto de Radioproteção e Dosimetria (LNMRI/IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil). Lab. Nacional de Metrologia das Radiações Ionizantes

    2017-07-01

    The 4πβ-γ coincidence counting and CIEMAT/NIST liquid scintillation method were used in the standardization of a solution of {sup 152}Eu. In CIEMAT/NIST method, measurements were performed in a Liquid Scintillation Counter model Wallac 1414. In the 4πβ-γ coincidence counting, the solution was standardized using a coincidence method with 'beta-efficiency extrapolation'. A simple 4πβ-γ coincidence system was used, with acrylic scintillation cell coupled to two coincident photomultipliers at 180° each other and NaI(Tl) detector. The activity concentrations obtained were 156.934 ± 0.722 and 157.403 ± 0.113 kBq/g, respectively, for CIEMAT/NIST and 4πβ-γ coincidence counting measurement methods. (author)

  16. Analysis of femtosecond pump-probe photoelectron-photoion coincidence measurements applying Bayesian probability theory

    Science.gov (United States)

    Rumetshofer, M.; Heim, P.; Thaler, B.; Ernst, W. E.; Koch, M.; von der Linden, W.

    2018-06-01

    Ultrafast dynamical processes in photoexcited molecules can be observed with pump-probe measurements, in which information about the dynamics is obtained from the transient signal associated with the excited state. Background signals provoked by pump and/or probe pulses alone often obscure these excited-state signals. Simple subtraction of pump-only and/or probe-only measurements from the pump-probe measurement, as commonly applied, results in a degradation of the signal-to-noise ratio and, in the case of coincidence detection, the danger of overrated background subtraction. Coincidence measurements additionally suffer from false coincidences, requiring long data-acquisition times to keep erroneous signals at an acceptable level. Here we present a probabilistic approach based on Bayesian probability theory that overcomes these problems. For a pump-probe experiment with photoelectron-photoion coincidence detection, we reconstruct the interesting excited-state spectrum from pump-probe and pump-only measurements. This approach allows us to treat background and false coincidences consistently and on the same footing. We demonstrate that the Bayesian formalism has the following advantages over simple signal subtraction: (i) the signal-to-noise ratio is significantly increased, (ii) the pump-only contribution is not overestimated, (iii) false coincidences are excluded, (iv) prior knowledge, such as positivity, is consistently incorporated, (v) confidence intervals are provided for the reconstructed spectrum, and (vi) it is applicable to any experimental situation and noise statistics. Most importantly, by accounting for false coincidences, the Bayesian approach allows us to run experiments at higher ionization rates, resulting in a significant reduction of data acquisition times. The probabilistic approach is thoroughly scrutinized by challenging mock data. The application to pump-probe coincidence measurements on acetone molecules enables quantitative interpretations

  17. Summing coincidence errors using Eu-152 lungs to calibrate a lung-counting system: are they significant?

    International Nuclear Information System (INIS)

    Kramer, Gary H.; Lynch, Timothy P.; Lopez, Maria A.; Hauck, Brian

    2004-01-01

    The use of a lung phantom containing 152Eu/241Am activity can provide a sufficient number of energy lines to generate an efficiency calibration for the in vivo measurements of radioactive materials in the lungs. However, due to the number of energy lines associated with 152Eu, coincidence summing occurs and can present a problem when using such a phantom for calibrating lung-counting systems. A Summing Peak Effect Study was conducted at three laboratories to determine the effect of using an efficiency calibration based on a 152Eu/241Am lung phantom. The measurement data at all three laboratories showed the presence of sum peaks. However, two of the three laboratories found only small biases (<5%) when using the 152Eu/241Am calibration. The third facility noted a 25% to 30% positive bias in the 140-keV to 190-keV energy range that prevents the use of the 152Eu/241Am lung phantom for routine calibrations. Although manufactured by different vendors, the three facilities use similar types of detectors (38 cm2 by 25 mm thick or 38 cm2 by 30 mm thick) for counting. These study results underscore the need to evaluate the coincidence summing effect when using a nuclide such as 152Eu for the calibration of low energy lung counting systems

  18. High Sensitivity Detection of Xe Isotopes Via Beta-Gamma Coincidence Counting

    International Nuclear Information System (INIS)

    Bowyer, Ted W.; McIntyre, Justin I.; Reeder, Paul L.

    1999-01-01

    Measurement of xenon fission product isotopes is a key element in the global network being established to monitor the Comprehensive Nuclear-Test-Ban Treaty. Pacific Northwest National Laboratory has developed an automated system for separating Xe from air which includes a beta-gamma counting system for 131mXe, 133mXe, 133Xe, and 135Xe. Betas and conversion electrons are detected in a plastic scintillation cell containing the Xe sample. The counting geometry is nearly 100% for beta and conversion electrons. The resolution in the pulse height spectrum from the plastic scintillator is sufficient to observe distinct peaks for specific conversion electrons. Gamma and X-rays are detected in a NaI(Tl) scintillation detector which surrounds the plastic scintillator sample cell. Two-dimensional pulse height spectra of gamma energy versus beta energy are obtained. Each of the four xenon isotopes has a distinctive signature in the two-dimensional energy array. The details of the counting system, examples of two-dimensional beta-gamma data, and operational experience with this counting system will be described

  19. 65Zn and 133Ba standardizing by photon-photon coincidence counting

    Science.gov (United States)

    Loureiro, Jamir S.; da Cruz, Paulo A. L.; Iwahara, Akira; Delgado, José U.; Lopes, Ricardo T.

    2018-03-01

    The LNMRI/Brazil has deployed a system using X-gamma coincidence technique for the standardizing radionuclide, which present simple and complex decay scheme with X-rays of energy below 100 keV. The work was carried on radionuclide metrology laboratory using a sodium iodide detector, for gamma photons, in combination with a high purity germanium detector for X-rays. Samples of 65Zn and 133Ba were standardized and the results for both radionuclides showed good precision and accuracy when compared with reference values. The standardization differences were 0.72 % for 65Zn and 0.48 % for 133Ba samples.

  20. 65Zn and 133Ba standardizing by photon-photon coincidence counting

    International Nuclear Information System (INIS)

    Loureiro, Jamir S.; Cruz, Paulo A.L. da; Iwahara, Akira; Delgado, José U.; Lopes, Ricardo T.

    2017-01-01

    The LNMRI/Brazil has deployed a system using X-gamma coincidence technique for the standardizing radionuclide, which present simple and complex decay scheme with X-rays of energy below 100 keV. The work was carried on radionuclide metrology laboratory using a sodium iodide detector, for gamma photons, in combination with a high purity germanium detector for X-rays. Samples of 65 Zn and 133 Ba were standardized and the results for both radionuclides showed good precision and accuracy when compared with reference values. The standardization differences were 0.72 % for 65 Zn and 0.48 % for 133 Ba samples. (author)

  1. {sup 65}Zn and {sup 133}Ba standardizing by photon-photon coincidence counting

    Energy Technology Data Exchange (ETDEWEB)

    Loureiro, Jamir S.; Cruz, Paulo A.L. da; Iwahara, Akira; Delgado, José U., E-mail: palcruz@ird.gov.br [Instituto de Radioproteção e Dosimetria (LNMRI/IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil). Lab. Nacional de Metrologia das Radiações Ionizantes; Lopes, Ricardo T. [Coordenacao de Pos-Graduacao e Pesquisa de Engenharia (PEN/COPPE/UFRJ), Rio de Janeiro, RJ (Brazil). Programa de Engenharia Nuclear

    2017-07-01

    The LNMRI/Brazil has deployed a system using X-gamma coincidence technique for the standardizing radionuclide, which present simple and complex decay scheme with X-rays of energy below 100 keV. The work was carried on radionuclide metrology laboratory using a sodium iodide detector, for gamma photons, in combination with a high purity germanium detector for X-rays. Samples of {sup 65}Zn and {sup 133}Ba were standardized and the results for both radionuclides showed good precision and accuracy when compared with reference values. The standardization differences were 0.72 % for {sup 65}Zn and 0.48 % for {sup 133}Ba samples. (author)

  2. Characterizations of double pulsing in neutron multiplicity and coincidence counting systems

    Energy Technology Data Exchange (ETDEWEB)

    Koehler, Katrina E., E-mail: kkoehler@lanl.gov [Los Alamos National Laboratory, P. O. Box 1663, Los Alamos, NM 87545 (United States); Henzl, Vladimir [Los Alamos National Laboratory, P. O. Box 1663, Los Alamos, NM 87545 (United States); Croft, Stephen S. [Oak Ridge National Laboratory, 1 Bethel Valley Rd, Oak Ridge, TN 37831 (United States); Henzlova, Daniela; Santi, Peter A. [Los Alamos National Laboratory, P. O. Box 1663, Los Alamos, NM 87545 (United States)

    2016-10-01

    Passive neutron coincidence/multiplicity counters are subject to non-ideal behavior, such as double pulsing and dead time. It has been shown in the past that double-pulsing exhibits a distinct signature in a Rossi-alpha distribution, which is not readily noticed using traditional Multiplicity Shift Register analysis. However, it has been assumed that the use of a pre-delay in shift register analysis removes any effects of double pulsing. In this work, we use high-fidelity simulations accompanied by experimental measurements to study the effects of double pulsing on multiplicity rates. By exploiting the information from the double pulsing signature peak observable in the Rossi-alpha distribution, the double pulsing fraction can be determined. Algebraic correction factors for the multiplicity rates in terms of the double pulsing fraction have been developed. We discuss the role of these corrections across a range of scenarios.

  3. Positron emission measurement with coincidence counting technic using large plastic scintillators

    International Nuclear Information System (INIS)

    Espinasse, P.; Minchella, P.

    1990-01-01

    For measuring positron emission of a large organ such as the brain for example, a device has been built with two cylindric plastic scintillators allowing the detection in coincidence of the 511 keV gamma rays without any spectrometry. The main results are for the sensitivity at the center of the field with 22 Na source in water: 240 ips/MBq; background = 12 ips, and for the countloss due to the deadtime >5% with 42 MBq. Sensitivity is almost uniform on the main axis between the probes. It falls to about 50% on the edges of a central diameter of 20 cm. The performances could certainly be improved by using modern rapid photomultipliers [fr

  4. The Absolute Standardization Method of 18F by Using 4π(PC)-γ Coincidence Counting System

    International Nuclear Information System (INIS)

    Pujadi

    2003-01-01

    The absolute standardization of 18 F radionuclide had been carried out using 4π(PC)-γ coincidence counting. The radionuclide 18 F fluoro 2 deoxyglucose (FDG) was the quantity used at nuclear medicine in diagnosis of oncology. The radionuclide 18 F had been produced by 18 O(p,n) 18 F reaction in a cyclotron. Source preparation had been done by gravimetry method after source was dissolved in aquadest. The samples have been measured using 4π(PC)-γ coincidence counting on different three window gamma energy, the gamma windows were set on 511 keV peak, 1022 keV and above 511 keV region. The result of measurement on 1022 keV peak and above 511 keV region, are fairly good with discrepancy about 0.15%, but the linearity of gamma window above 511 keV is the best with R 2 = 0.8287. The measurement on 511 keV gamma window region gave the result with difference 2.28% compared with another two region. (author)

  5. Fast digital 4πβ-4πγ coincidence counting with offline analysis at IRA.

    Science.gov (United States)

    Teresa Durán, M; Nedjadi, Youcef; Juget, Frédéric; Bochud, François; Bailat, Claude

    2018-04-01

    IRA recently launched a project to digitize all the data acquisition systems it uses for primary radionuclide standardizations. It is well-known that the digital approach presents numerous advantages over the traditional analog electronics such as information losslessness, scalability, online and/or offline data processing, and it is also a solution to the growing difficulties to repair or renew ageing modules. As a first step in this wider program, our institute set-up a 4πβ-4πγ digital coincidence counting system, with FPGA (Field Programmable Gate Array)-based commercial boards from National Instruments (NI), to perform data acquisition and offline data analysis. Choosing all components and software from the same supplier provides a full compact and consistent electronic system. To demonstrate and validate the capacity of this system to standardize the activity of radioisotopes, we compare its predictions for the activity concentration of 133 Ba, 166m Ho and 18 F solutions with the results from a coincidence counting system with analog electronics, as well as with the results from other primary methods and a secondary measurement performed with an IG11 ionization chamber (CIR, chambre d'ionization de référence) with an equivalent activity traceable to the Système International de Référence. Copyright © 2017 Elsevier Ltd. All rights reserved.

  6. Patient-dependent count-rate adaptive normalization for PET detector efficiency with delayed-window coincidence events

    International Nuclear Information System (INIS)

    Niu, Xiaofeng; Ye, Hongwei; Xia, Ting; Asma, Evren; Gagnon, Daniel; Wang, Wenli; Winkler, Mark

    2015-01-01

    Quantitative PET imaging is widely used in clinical diagnosis in oncology and neuroimaging. Accurate normalization correction for the efficiency of each line-of- response is essential for accurate quantitative PET image reconstruction. In this paper, we propose a normalization calibration method by using the delayed-window coincidence events from the scanning phantom or patient. The proposed method could dramatically reduce the ‘ring’ artifacts caused by mismatched system count-rates between the calibration and phantom/patient datasets. Moreover, a modified algorithm for mean detector efficiency estimation is proposed, which could generate crystal efficiency maps with more uniform variance. Both phantom and real patient datasets are used for evaluation. The results show that the proposed method could lead to better uniformity in reconstructed images by removing ring artifacts, and more uniform axial variance profiles, especially around the axial edge slices of the scanner. The proposed method also has the potential benefit to simplify the normalization calibration procedure, since the calibration can be performed using the on-the-fly acquired delayed-window dataset. (paper)

  7. Standardization of {sup 67}Ga, {sup 51}Cr and {sup 55}Fe by live-timed anti-coincidence counting with extending dead time

    Energy Technology Data Exchange (ETDEWEB)

    Silva, Carlos J. da [Laboratorio Nacional de Metrologia das Radiacoes Ionizantes (LNMRI), Instituto de Radioprotecao e Dosimetria (IRD), Comissao Nacional de Energia Nuclear - CNEN, Av. Salvador Allende, s/n0-Recreio, CEP 22780-160 Rio de Janeiro (Brazil) and Laboratorio de Instrumentacao Nuclear (LIN/PEN/COPPE/UFRJ), Caixa Postal 68590, CEP 21945-970 Rio de Janeiro (Brazil)], E-mail: Carlos@ird.gov.br; Iwahara, A.; Poledna, R.; Bernardes, E.M. de O; Prinzio, M.A.R.R. de [Laboratorio Nacional de Metrologia das Radiacoes Ionizantes (LNMRI), Instituto de Radioprotecao e Dosimetria (IRD), Comissao Nacional de Energia Nuclear - CNEN, Av. Salvador Allende, s/n0-Recreio, CEP 22780-160 Rio de Janeiro (Brazil); Lopes, Ricardo T. [Laboratorio de Instrumentacao Nuclear (LIN/PEN/COPPE/UFRJ), Caixa Postal 68590, CEP 21945-970 Rio de Janeiro (Brazil)

    2008-02-15

    In this work, the activity standardization of {sup 51}Cr, {sup 55}Fe and {sup 67}Ga by live-timed anti-coincidence counting with extending dead time is described. The difficulties of the method, the uncertainties of the results of the measurements and the comparison of these results with others measurement methods are discussed.

  8. A Rapid Coordinate Transformation Method Applied in Industrial Robot Calibration Based on Characteristic Line Coincidence

    Science.gov (United States)

    Liu, Bailing; Zhang, Fumin; Qu, Xinghua; Shi, Xiaojia

    2016-01-01

    Coordinate transformation plays an indispensable role in industrial measurements, including photogrammetry, geodesy, laser 3-D measurement and robotics. The widely applied methods of coordinate transformation are generally based on solving the equations of point clouds. Despite the high accuracy, this might result in no solution due to the use of ill conditioned matrices. In this paper, a novel coordinate transformation method is proposed, not based on the equation solution but based on the geometric transformation. We construct characteristic lines to represent the coordinate systems. According to the space geometry relation, the characteristic line scan is made to coincide by a series of rotations and translations. The transformation matrix can be obtained using matrix transformation theory. Experiments are designed to compare the proposed method with other methods. The results show that the proposed method has the same high accuracy, but the operation is more convenient and flexible. A multi-sensor combined measurement system is also presented to improve the position accuracy of a robot with the calibration of the robot kinematic parameters. Experimental verification shows that the position accuracy of robot manipulator is improved by 45.8% with the proposed method and robot calibration. PMID:26901203

  9. A Rapid Coordinate Transformation Method Applied in Industrial Robot Calibration Based on Characteristic Line Coincidence

    Directory of Open Access Journals (Sweden)

    Bailing Liu

    2016-02-01

    Full Text Available Coordinate transformation plays an indispensable role in industrial measurements, including photogrammetry, geodesy, laser 3-D measurement and robotics. The widely applied methods of coordinate transformation are generally based on solving the equations of point clouds. Despite the high accuracy, this might result in no solution due to the use of ill conditioned matrices. In this paper, a novel coordinate transformation method is proposed, not based on the equation solution but based on the geometric transformation. We construct characteristic lines to represent the coordinate systems. According to the space geometry relation, the characteristic line scan is made to coincide by a series of rotations and translations. The transformation matrix can be obtained using matrix transformation theory. Experiments are designed to compare the proposed method with other methods. The results show that the proposed method has the same high accuracy, but the operation is more convenient and flexible. A multi-sensor combined measurement system is also presented to improve the position accuracy of a robot with the calibration of the robot kinematic parameters. Experimental verification shows that the position accuracy of robot manipulator is improved by 45.8% with the proposed method and robot calibration.

  10. SU-G-IeP4-12: Performance of In-111 Coincident Gamma-Ray Counting: A Monte Carlo Simulation

    Energy Technology Data Exchange (ETDEWEB)

    Pahlka, R; Kappadath, S; Mawlawi, O [UT MD Anderson Cancer Center, Houston, TX (United States)

    2016-06-15

    Purpose: The decay of In-111 results in a non-isotropic gamma-ray cascade, which is normally imaged using a gamma camera. Creating images with a gamma camera using coincident gamma-rays from In-111 has not been previously studied. Our objective was to explore the feasibility of imaging this cascade as coincidence events and to determine the optimal timing resolution and source activity using Monte Carlo simulations. Methods: GEANT4 was used to simulate the decay of the In-111 nucleus and to model the gamma camera. Each photon emission was assigned a timestamp, and the time delay and angular separation for the second gamma-ray in the cascade was consistent with the known intermediate state half-life of 85ns. The gamma-rays are transported through a model of a Siemens dual head Symbia “S” gamma camera with a 5/8-inch thick crystal and medium energy collimators. A true coincident event was defined as a single 171keV gamma-ray followed by a single 245keV gamma-ray within a specified time window (or vice versa). Several source activities (ranging from 10uCi to 5mCi) with and without incorporation of background counts were then simulated. Each simulation was analyzed using varying time windows to assess random events. The noise equivalent count rate (NECR) was computed based on the number of true and random counts for each combination of activity and time window. No scatter events were assumed since sources were simulated in air. Results: As expected, increasing the timing window increased the total number of observed coincidences albeit at the expense of true coincidences. A timing window range of 200–500ns maximizes the NECR at clinically-used source activities. The background rate did not significantly alter the maximum NECR. Conclusion: This work suggests coincident measurements of In-111 gamma-ray decay can be performed with commercial gamma cameras at clinically-relevant activities. Work is ongoing to assess useful clinical applications.

  11. Instrumentation and procedures for moisture corrections to passive neutron coincidence counting assays of bulk PuO2 and MOX powders

    International Nuclear Information System (INIS)

    Stewart, J.E.; Menlove, H.O.; Ferran, R.R.; Aparo, M.; Zeppa, P.; Troiani, F.

    1993-05-01

    For passive neutron-coincidence-counting verification measurements of PuO 2 and MOX powder, assay biases have been observed that result from moisture entrained in the sample. This report describes a unique set of experiments in which MOX samples, with a range of moisture concentrations, were produced and used to calibrate and evaluate two prototype moisture monitors. A new procedure for moisture corrections to PuO 2 and MOX verification measurements yields MOX assays accurate to 1.5% (1σ) for 0.6- and 1.1-kg samples. Monte Carlo simulations were used to extend the measured moisture calibration data to higher sample masses. A conceptual design for a high-efficiency neutron coincidence counter with improved sensitivity to moisture is also presented

  12. Comparison of triple to double coincidence ratio and Quench Parameter External methods for the determination of 3H efficiency by liquid scintillation counting

    International Nuclear Information System (INIS)

    Nisti, M.B.; Saueia, C.H.R.; Mazzilli, B.P.

    2013-01-01

    The aim of this study is to determine the tritium efficiency by liquid scintillation counting using two methodologies, Quench Parameter External (QPE) and Triple to Double Coincidence Ratio (TDCR), and to compare the results. The equipment used was the HIDEX model 300-SL Liquid Scintillation Counter, composed of three photomultipliers coupled with coincidence pulses, discrimination level and Mikro Win 2000 software. The efficiency varied from 0.028 to 0.706 cps dps -1 for QPE and from 0.061 to 0.703 cps dps -1 for TDCR. Different efficiencies were obtained using both methods, in the range from 459 to 572 quenching, above this range the efficiencies were similar. The verification of the efficiencies was performed by participating in the Intercomparison National Program (PNI). (author)

  13. Reflected‑Point‑Reactor Kinetics Model for Neutron Coincidence Counting: Comments on the Equation for the Leakage Self‑Multiplication

    International Nuclear Information System (INIS)

    Croft, S.; McElroy, RD.; Favalli, A.; Hauck, D.; Henzlova, D.; Henzl, V.; Santi, PA.

    2015-01-01

    Passive neutron correlation counting is widely used, for example by international inspection agencies, for the non‑destructive assay of spontaneously fissile nuclear materials for nuclear safeguards. The mass of special nuclear material present in an item is usually estimated from the observed neutron counting rates by using equations based on mathematically describing the object as an isolated multiplying point‑like source. Calibration using representative physical standards can often adequately compensate for this theoretical oversimplification through the introduction and use of effective‑interpretational‑model‑parameters meaning that useful assay results are obtained. In this work we extend the point‑model treatment by including a simple reflector around the fissioning material. Specifically we show how the leakage self‑multiplication equation mathematically connects the traditional bare source and the reflected source cases. In doing so we explicitly demonstrate that although the presence of a simple reflector changes the leakage self‑multiplication the traditional bare‑item point model multiplicity equations retain the same mathematical form. Making and explaining this connection is important because it helps to explain and justify the practical success and use of the traditional point‑model equations even when the assumptions used to generate the key functional dependences are violated. We are not aware that this point has been recognized previously.

  14. Ultrafast photon counting applied to resonant scanning STED microscopy.

    Science.gov (United States)

    Wu, Xundong; Toro, Ligia; Stefani, Enrico; Wu, Yong

    2015-01-01

    To take full advantage of fast resonant scanning in super-resolution stimulated emission depletion (STED) microscopy, we have developed an ultrafast photon counting system based on a multigiga sample per second analogue-to-digital conversion chip that delivers an unprecedented 450 MHz pixel clock (2.2 ns pixel dwell time in each scan). The system achieves a large field of view (∼50 × 50 μm) with fast scanning that reduces photobleaching, and advances the time-gated continuous wave STED technology to the usage of resonant scanning with hardware-based time-gating. The assembled system provides superb signal-to-noise ratio and highly linear quantification of light that result in superior image quality. Also, the system design allows great flexibility in processing photon signals to further improve the dynamic range. In conclusion, we have constructed a frontier photon counting image acquisition system with ultrafast readout rate, excellent counting linearity, and with the capacity of realizing resonant-scanning continuous wave STED microscopy with online time-gated detection. © 2014 The Authors Journal of Microscopy © 2014 Royal Microscopical Society.

  15. Design of an electronic system with simultaneous registering of pulse amplitude and event time applied to the 4πβ-γ coincidence method

    International Nuclear Information System (INIS)

    Toledo, Fabio de

    2009-01-01

    The 4πβ-γ coincidence method for absolute radionuclide activity measurement has been considered for many years as a primary standard in Nuclear Metrology, because of dependence on few observable quantities and high accuracy. The Laboratorio de Metrologia Nuclear (LMN) - Nuclear Metrology Laboratory -, at Instituto de Pesquisas Energeticas e Nucleares (IPEN) - Nuclear and Energy Research Institute -, among its measurement techniques, uses the 4πβ-γ coincidence method. Recently a new technique known as 'software coincidence' has been used, with many advantages over the conventional coincidence methodology. In order to update the methodologies for radionuclide standardizations, the LMN developed a new system based on the software coincidence technique, described in the present work. This system uses the same nuclear set up for beta and gamma detection. The new software coincidence electronics uses a National Instruments (NI) acquisition card connected to a microcomputer and, through a connection panel, to the nuclear detection set up. The card configuration and controlling is accomplished by software using the LabVIEW, a NI proprietary product. This system records into disk files all the amplitudes and occurrence times for beta and gamma detected pulses. A suitable software was developed (the coincidence analysis program) to process the recorded data in order to obtain beta, gamma and coincidence counts and perform calculation of the radioactive source activity. The work also presents and discusses the results obtained with the first version of the coincidence analysis program, as well as perspectives for future works. (author)

  16. Applying Multivariate Discrete Distributions to Genetically Informative Count Data.

    Science.gov (United States)

    Kirkpatrick, Robert M; Neale, Michael C

    2016-03-01

    We present a novel method of conducting biometric analysis of twin data when the phenotypes are integer-valued counts, which often show an L-shaped distribution. Monte Carlo simulation is used to compare five likelihood-based approaches to modeling: our multivariate discrete method, when its distributional assumptions are correct, when they are incorrect, and three other methods in common use. With data simulated from a skewed discrete distribution, recovery of twin correlations and proportions of additive genetic and common environment variance was generally poor for the Normal, Lognormal and Ordinal models, but good for the two discrete models. Sex-separate applications to substance-use data from twins in the Minnesota Twin Family Study showed superior performance of two discrete models. The new methods are implemented using R and OpenMx and are freely available.

  17. The coincidence counting technique for orders of magnitude background reduction in data obtained with the magnetic recoil spectrometer at OMEGA and the NIF

    International Nuclear Information System (INIS)

    Casey, D. T.; Frenje, J. A.; Seguin, F. H.; Li, C. K.; Rosenberg, M. J.; Rinderknecht, H.; Manuel, M. J.-E.; Gatu Johnson, M.; Schaeffer, J. C.; Frankel, R.; Sinenian, N.; Childs, R. A.; Petrasso, R. D.; Glebov, V. Yu.; Sangster, T. C.; Burke, M.; Roberts, S.

    2011-01-01

    A magnetic recoil spectrometer (MRS) has been built and successfully used at OMEGA for measurements of down-scattered neutrons (DS-n), from which an areal density in both warm-capsule and cryogenic-DT implosions have been inferred. Another MRS is currently being commissioned on the National Ignition Facility (NIF) for diagnosing low-yield tritium-hydrogen-deuterium implosions and high-yield DT implosions. As CR-39 detectors are used in the MRS, the principal sources of background are neutron-induced tracks and intrinsic tracks (defects in the CR-39). The coincidence counting technique was developed to reduce these types of background tracks to the required level for the DS-n measurements at OMEGA and the NIF. Using this technique, it has been demonstrated that the number of background tracks is reduced by a couple of orders of magnitude, which exceeds the requirement for the DS-n measurements at both facilities.

  18. Cosmic-muon intensity measurement and overburden estimation in a building at surface level and in an underground facility using two BC408 scintillation detectors coincidence counting system.

    Science.gov (United States)

    Zhang, Weihua; Ungar, Kurt; Liu, Chuanlei; Mailhot, Maverick

    2016-10-01

    A series of measurements have been recently conducted to determine the cosmic-muon intensities and attenuation factors at various indoor and underground locations for a gamma spectrometer. For this purpose, a digital coincidence spectrometer was developed by using two BC408 plastic scintillation detectors and an XIA LLC Digital Gamma Finder (DGF)/Pixie-4 software and card package. The results indicate that the overburden in the building at surface level absorbs a large part of cosmic ray protons while attenuating the cosmic-muon intensity by 20-50%. The underground facility has the largest overburden of 39 m water equivalent, where the cosmic-muon intensity is reduced by a factor of 6. The study provides a cosmic-muon intensity measurement and overburden assessment, which are important parameters for analysing the background of an HPGe counting system, or for comparing the background of similar systems. Copyright © 2016 Elsevier Ltd. All rights reserved.

  19. The coincidence counting technique for orders of magnitude background reduction in data obtained with the magnetic recoil spectrometer at OMEGA and the NIF.

    Science.gov (United States)

    Casey, D T; Frenje, J A; Séguin, F H; Li, C K; Rosenberg, M J; Rinderknecht, H; Manuel, M J-E; Gatu Johnson, M; Schaeffer, J C; Frankel, R; Sinenian, N; Childs, R A; Petrasso, R D; Glebov, V Yu; Sangster, T C; Burke, M; Roberts, S

    2011-07-01

    A magnetic recoil spectrometer (MRS) has been built and successfully used at OMEGA for measurements of down-scattered neutrons (DS-n), from which an areal density in both warm-capsule and cryogenic-DT implosions have been inferred. Another MRS is currently being commissioned on the National Ignition Facility (NIF) for diagnosing low-yield tritium-hydrogen-deuterium implosions and high-yield DT implosions. As CR-39 detectors are used in the MRS, the principal sources of background are neutron-induced tracks and intrinsic tracks (defects in the CR-39). The coincidence counting technique was developed to reduce these types of background tracks to the required level for the DS-n measurements at OMEGA and the NIF. Using this technique, it has been demonstrated that the number of background tracks is reduced by a couple of orders of magnitude, which exceeds the requirement for the DS-n measurements at both facilities.

  20. Development of an analysis methodology applied to 4πβ-γ software coincidence data acquisition system

    International Nuclear Information System (INIS)

    Brancaccio, Franco; Dias, Mauro da Silva; Toledo, Fabio de

    2009-01-01

    The present work describes the new software methodology under development at the IPEN Nuclear Metrology Laboratory for radionuclide standardizations with 4πβ-γ coincidence technique. The software includes the Coincidence Graphic User Interface (GUI) and the Coincidence Analysis Program. The first results for a 60 Co sample measurement are discussed and compared to the results obtained with two different conventional coincidence systems. (author)

  1. A pulse stacking method of particle counting applied to position sensitive detection

    International Nuclear Information System (INIS)

    Basilier, E.

    1976-03-01

    A position sensitive particle counting system is described. A cyclic readout imaging device serves as an intermediate information buffer. Pulses are allowed to stack in the imager at very high counting rates. Imager noise is completely discriminated to provide very wide dynamic range. The system has been applied to a detector using cascaded microchannel plates. Pulse height spread produced by the plates causes some loss of information. The loss is comparable to the input loss of the plates. The improvement in maximum counting rate is several hundred times over previous systems that do not permit pulse stacking. (Auth.)

  2. The use of computed neutron coincidence counting with time interval analysis for the analysis of Fork-measurements on a fresh MOX-LWR fuel assembly under water

    Energy Technology Data Exchange (ETDEWEB)

    Baeten, P.; Bruggeman, M.; Carchon, R

    1998-06-01

    The objective of this study was to investigate the influence of different important parameters on measurement results for various fork-detectors. Computed Neutron Coincidence Counting (CNCC) with Time Interval Analysis (TIA) was used for this study. The performance of the electronics for the different fork-detectors was studied by investigating the deadtime perturbed zone of the Rossi-alpha distribution in TIA. The measurement revealed anomalies in the performance of the electronics of the IAEA BWR and LANL fork-detector. The IAEA PWR fork-detector functioned well and the deadtime parameter was calculated. The optimal setting for the pre delay was investigated and it was found that a pre delay of 10 micro seconds should be considered as an optimum between excluding from analysis data in the deadtime perturbed zone and keeping a high signal-to-noise ratio. For the shift register electronics used with the fork-detectors, a pre delay of only 4.5 micro seconds was used. The study of the pre delay and the deadtime showed that the calculated triples-rate is strongly dependent on these parameters. An accurate determination of the triple-rate in this type of measurements has proven to be quite difficult and requires proper operation of the electronics, a correct pre delay and an accurate deadtime correction formalism. By varying the boron concentration in water, the change of the decay time of the Rossi-alpha distribution was clearly observed. This change is due to the variation of the thermal multiplication. The variation of this decay time with the boron concentration proves that Boehnel's model for fast neutron multiplication is not valid under these measurement conditions and that a model for fast and thermal multiplication should be used in order to obtain unbiased measurement results. CNCC with TIA has proved to be a valuable tool in which parameter settings can be varied a posterori and the optimal setting can be determined for each measurement. Moreover, the

  3. The use of computed neutron coincidence counting with time interval analysis for the analysis of Fork-measurements on a fresh MOX-LWR fuel assembly under water

    International Nuclear Information System (INIS)

    Baeten, P.; Bruggeman, M.; Carchon, R.

    1998-06-01

    The objective of this study was to investigate the influence of different important parameters on measurement results for various fork-detectors. Computed Neutron Coincidence Counting (CNCC) with Time Interval Analysis (TIA) was used for this study. The performance of the electronics for the different fork-detectors was studied by investigating the deadtime perturbed zone of the Rossi-alpha distribution in TIA. The measurement revealed anomalies in the performance of the electronics of the IAEA BWR and LANL fork-detector. The IAEA PWR fork-detector functioned well and the deadtime parameter was calculated. The optimal setting for the pre delay was investigated and it was found that a pre delay of 10 micro seconds should be considered as an optimum between excluding from analysis data in the deadtime perturbed zone and keeping a high signal-to-noise ratio. For the shift register electronics used with the fork-detectors, a pre delay of only 4.5 micro seconds was used. The study of the pre delay and the deadtime showed that the calculated triples-rate is strongly dependent on these parameters. An accurate determination of the triple-rate in this type of measurements has proven to be quite difficult and requires proper operation of the electronics, a correct pre delay and an accurate deadtime correction formalism. By varying the boron concentration in water, the change of the decay time of the Rossi-alpha distribution was clearly observed. This change is due to the variation of the thermal multiplication. The variation of this decay time with the boron concentration proves that Boehnel's model for fast neutron multiplication is not valid under these measurement conditions and that a model for fast and thermal multiplication should be used in order to obtain unbiased measurement results. CNCC with TIA has proved to be a valuable tool in which parameter settings can be varied a posterori and the optimal setting can be determined for each measurement. Moreover, the

  4. A β - γ coincidence

    International Nuclear Information System (INIS)

    Agullo, F.

    1960-01-01

    A β - γ coincidence method for absolute counting is given. The fundamental principles are revised and the experimental part is detailed. The results from 1 98 Au irradiated in the JEN 1 Swimming pool reactor are given. The maximal accuracy is 1 per cent. (Author) 11 refs

  5. Neutron coincidence counting based on time interval analysis with dead time corrected one and two dimensional Rossi-alpha distributions: an application for passive neutron waste assay

    International Nuclear Information System (INIS)

    Bruggeman, M.; Baeten, P.; De Boeck, W.; Carchon, R.

    1996-03-01

    The report describes a new neutron multiplicity counting method based on Rossi-alpha distributions. The report also gives the necessary dead time correction formulas for the multiplicity counting method. The method was tested numerically using a Monte Carlo simulation of pulse trains. The use of this multiplicity method in the field of waste assay is explained: it can be used to determine the amount of fissile material in a waste drum without prior knowledge of the actual detection efficiency

  6. Determining random counts in liquid scintillation counting

    International Nuclear Information System (INIS)

    Horrocks, D.L.

    1979-01-01

    During measurements involving coincidence counting techniques, errors can arise due to the detection of chance or random coincidences in the multiple detectors used. A method and the electronic circuits necessary are here described for eliminating this source of error in liquid scintillation detectors used in coincidence counting. (UK)

  7. Measurement of disintegration rate and decay branching ratio for nuclide 192Ir with β-, EC mixing decays by using 4πβ-γ coincidence counting

    International Nuclear Information System (INIS)

    Yan Chunguang; Pei Wulang; Li Wei; Qu Decheng; Xiong Jing; Chang Yongfu

    1995-01-01

    The absolute disintegration rates for nuclide 192 Ir were measured with a 4πβ-γ (HPGe) coincidence apparatus by using parameter method and extrapolation method. The final uncertainties obtained were 0.4% and 0.5% respectively for a confidence level of 99.7%. The method with which both the disintegration rate and the decay branching ratio can be measured for nuclides with β - and EC mixing decays was proposed and described. The β - branching ratio in 192 Ir decays was measured being 0.9572. The final uncertainties of disintegration rates and β - decay branching ratio with this method were 1.5% and 1.8% respectively

  8. Standardization of {sup 241}Am, {sup 124}Sb and {sup 131}I by live-timed anti-coincidence counting with extending dead time

    Energy Technology Data Exchange (ETDEWEB)

    Silva, Carlos J. da [Laboratorio Nacional de Metrologia das Radiacoes Ionizantes (LNMRI), Instituto de Radioprotecao e Dosimetria (IRD), Comissao Nacional de Energia Nuclear - CNEN, Av. Salvador Allende, s/n-Recreio, CEP 22780-160 Rio de Janeiro (Brazil) and Laboratorio de Instrumentacao Nuclear (LIN/PEN/COPPE/UFRJ), Caixa Postal 68590, CEP 21945-970 Rio de Janeiro (Brazil)], E-mail: Carlos@ird.gov.br; Iwahara, A.; Poledna, R.; Oliveira, E.M. de; Prinzio, M.A.R.R. de; Delgado, Jose U. [Laboratorio Nacional de Metrologia das Radiacoes Ionizantes (LNMRI), Instituto de Radioprotecao e Dosimetria (IRD), Comissao Nacional de Energia Nuclear - CNEN, Av. Salvador Allende, s/n-Recreio, CEP 22780-160 Rio de Janeiro (Brazil); Lopes, Ricardo T. [Laboratorio de Instrumentacao Nuclear (LIN/PEN/COPPE/UFRJ), Caixa Postal 68590, CEP 21945-970 Rio de Janeiro (Brazil)

    2008-06-15

    The National Metrology Laboratory for Ionizing Radiation (LNMRI)/Brazil has implemented a live-timed anti-coincidence system with extending dead time to complement the existing systems in its Radionuclide Laboratory for activity measurements of radioactive sources. In this new system, the proportional counter has been replaced by a liquid-scintillation-counter for alpha and beta detection. In order to test the performance of the new system, radioactive solutions of {sup 131}I, {sup 124}Sb and {sup 241}Am have been standardized. In this work the measurement method, the results and the associated uncertainties are described and discussed.

  9. An algorithm for applying flagged Sysmex XE-2100 absolute neutrophil counts in clinical practice

    DEFF Research Database (Denmark)

    Friis-Hansen, Lennart; Saelsen, Lone; Abildstrøm, Steen Z

    2008-01-01

    BACKGROUND: Even though most differential leukocyte counts are performed by automated hematology platforms, turn-around time is often prolonged as flagging of test results trigger additional confirmatory manual procedures. However, frequently only the absolute neutrophil count (ANC) is needed. We...... therefore examined if an algorithm could be developed to identify samples in which the automated ANC is valid despite flagged test results. METHODS: During a 3-wk period, a training set consisting of 1448 consecutive flagged test-results from the Sysmex XE-2100 system and associated manual differential...... counts was collected. The training set was used to determine which alarms were associated with valid ANCs. The algorithm was then tested on a new set of 1371 test results collected during a later 3-wk period. RESULTS: Analysis of the training set data revealed that the ANC from test results flagged...

  10. Applying ultrasonographic evaluation of antral follicle count to improve reproductive management in heifers

    Science.gov (United States)

    Ultrasonography is a powerful technology that can be used to improve reproductive management in heifers. By counting the number of antral follicles observed on an ultrasound screen the practitioner can gather additional information when reproductive tract scoring, because the number of antral folli...

  11. Regression models for categorical, count, and related variables an applied approach

    CERN Document Server

    Hoffmann, John P

    2016-01-01

    Social science and behavioral science students and researchers are often confronted with data that are categorical, count a phenomenon, or have been collected over time. Sociologists examining the likelihood of interracial marriage, political scientists studying voting behavior, criminologists counting the number of offenses people commit, health scientists studying the number of suicides across neighborhoods, and psychologists modeling mental health treatment success are all interested in outcomes that are not continuous. Instead, they must measure and analyze these events and phenomena in a discrete manner.   This book provides an introduction and overview of several statistical models designed for these types of outcomes--all presented with the assumption that the reader has only a good working knowledge of elementary algebra and has taken introductory statistics and linear regression analysis.   Numerous examples from the social sciences demonstrate the practical applications of these models. The chapte...

  12. Principles of correlation counting

    International Nuclear Information System (INIS)

    Mueller, J.W.

    1975-01-01

    A review is given of the various applications which have been made of correlation techniques in the field of nuclear physics, in particular for absolute counting. Whereas in most cases the usual coincidence method will be preferable for its simplicity, correlation counting may be the only possible approach in such cases where the two radiations of the cascade cannot be well separated or when there is a longliving intermediate state. The measurement of half-lives and of count rates of spurious pulses is also briefly discussed. The various experimental situations lead to different ways the correlation method is best applied (covariance technique with one or with two detectors, application of correlation functions, etc.). Formulae are given for some simple model cases, neglecting dead-time corrections

  13. Subtraction of random coincidences in γ-ray spectroscopy: A new approach

    International Nuclear Information System (INIS)

    Pattabiraman, N.S.; Ghugre, S.S.; Basu, S.K.; Garg, U.; Ray, S.; Sinha, A.K.; Zhu, S.

    2006-01-01

    A new analytical method for estimation and subsequent subtraction of random coincidences has been developed. It utilizes the knowledge of the counts in the main diagonal of a background-subtracted symmetric data set for the estimation of the events originating from random coincidences. This procedure has been successfully applied to several data sets. It could be a valuable tool for low-fold data sets, especially for low-cross-section events

  14. Measurement of plutonium oxalate in thermal neutron coincidence counters

    International Nuclear Information System (INIS)

    Marshall, R.S.; Erkkila, B.H.

    1979-01-01

    A coincidence neutron counting method has been developed for assaying batches of plutonium oxalate. Using counting data from two concentric rings of 3 He detectors, corrections are made for the effects that water has on the coincidence neutron count rate. Batches of plutonium oxalate varying from 750 to 1000 g of plutonium and from 34 to 54% water are assayed with an average accuracy of +-3%

  15. Digital pulse-shape discrimination applied to an ultra-low-background gas-proportional counting system. First results

    International Nuclear Information System (INIS)

    Aalseth, C.E.; Day, A.R.; Fuller, E.S.; Hoppe, E.W.; Keillor, M.E.; Mace, E.K.; Myers, A.W.; Overman, C.T.; Panisko, M.E.; Seifert, A.

    2013-01-01

    A new ultra-low-background proportional counter design was recently developed at Pacific Northwest National Laboratory (PNNL). This design, along with an ultra-low-background counting system which provides passive and active shielding with radon exclusion, has been developed to complement a new shallow underground laboratory (∼30 m water-equivalent) constructed at PNNL. After these steps to mitigate dominant backgrounds (cosmic rays, external gamma-rays, radioactivity in materials), remaining background events do not exclusively arise from ionization of the proportional counter gas. Digital pulse-shape discrimination (PSD) is thus employed to further improve measurement sensitivity. In this work, a template shape is generated for each individual sample measurement of interest, a 'self-calibrating' template. Differences in event topology can also cause differences in pulse shape. In this work, the temporal region analyzed for each event is refined to maximize background discrimination while avoiding unwanted sensitivity to event topology. This digital PSD method is applied to sample and background data, and initial measurement results from a biofuel methane sample are presented in the context of low-background measurements currently being developed. (author)

  16. Integrated coincidence circuits

    International Nuclear Information System (INIS)

    Borejko, V.F.; Grebenyuk, V.M.; Zinov, V.G.

    1976-01-01

    The description is given of two coincidence units employing integral circuits in the VISHNYA standard. The units are distinguished for the coincidence selection element which is essentially a combination of a tunnel diode and microcircuits. The output fast response of the units is at least 90 MHz in the mode of the output signal unshaped in duration and 50 MHz minimum in the mode of the output signal shaping. The resolution time of the units is dependent upon the duration of input signals

  17. Coincidence method for determination of radionuclides activities

    International Nuclear Information System (INIS)

    Andrukhovich, S.K.; Berestov, A.V.; Rudak, E.A.

    2004-01-01

    The radon and radium activity measurements using six-crystal gamma-gamma coincidence, 4 -spectrometer PRIPJAT and radioactivity measurements in different samples of meat and vegetation by 32-crystal spectrometer ARGUS, are described. Radiation detector with 4 -geometry provides higher efficiency, and therefore shorter counting time than a detector without such geometry. However, its application is limited by the fact that obtained spectrum contains summing peaks of all γ-quanta registered in coincidence. Multiparameter information on coincident photon emission can be obtained only by a detection system where the 4 -geometry is made by many detectors, such are both the PRIPJAT and the ARGUS - γ-coincidence spectrometer of the Crystal Ball type in the Institute of Physics, Minsk [1,2]. There are other characteristics, as background conditions, energy and time resolution, makes it ve suitable for investigation of rare decays and interactions, cascade transitions, k intensity radiations etc. We are developing a method of 2 26R a and 2 26 Rn measurement by a multidetector 4 -spectrometer. The method is based on coincidence counting of γ-rays from two step cascade transitions that follow - decay of 2 14 Bi. Its application to the PRIPL spectrometer, which has 6 Nal(Tl) detectors, is presented here, as well as the method of the determination of radionuclide activities based on the registration of the cascades intensity of γ-rays of different multiplicity using ARGUS

  18. Coincidence measurements of FFTF breeder fuel subassemblies

    International Nuclear Information System (INIS)

    Eccleston, G.W.; Foley, J.E.; Krick, M.; Menlove, H.O.; Goris, P.; Ramalho, A.

    1984-04-01

    A prototype coincidence counter developed to assay fast breeder reactor fuel was used to measure four fast-flux test facility subassemblies at the Hanford Engineering Development Laboratory in Richland, Washington. Plutonium contents in the four subassemblies ranged between 7.4 and 9.7 kg with corresponding 240 Pu-effective contents between 0.9 and 1.2 kg. Large count rates were observed from the measurements, and plots of the data showed significant multiplication in the fuel. The measured data were corrected for deadtime and multiplication effects using established formulas. These corrections require accurate knowledge of the plutonium isotopics and 241 Am content in the fuel. Multiplication-corrected coincidence count rates agreed with the expected count rates based on spontaneous fission-neutron emission rates. These measurements indicate that breeder fuel subassemblies with 240 Pu-effective contents up to 1.2 kg can be nondestructively assayed using the shift-register electronics with the prototype counters. Measurements using the standard Los Alamos National Laboratory shift-register coincidence electronics unit can produce an assay value accurate to +-1% in 1000 s. The uncertainty results from counting statistics and deadtime-correction errors. 3 references, 8 figures, 8 tables

  19. Coincidence studies with antiprotons

    Energy Technology Data Exchange (ETDEWEB)

    McGovern, M; Walters, H R J [Department of Applied Mathematics and Theoretical Physics, Queen' s University, Belfast BT7 1NN (United Kingdom); Assafrao, D; Mohallem, J R [Laboratorio de Atomos e Moleculas Especiais, Departamento de Fisica, ICEx, Universidade Federal de Minas Gerais, P.O Box 702, 30123-970 Belo Horizonte, MG (Brazil); Whelan, Colm T, E-mail: mmcgovern06@qub.ac.u [Department of Physics, Old Dominion University, Norfolk, VA 23529-0116 (United States)

    2010-02-01

    We present a short overview of a new method for calculating fully differential cross sections that is able to describe any aspect of coincidence measurements involving heavy projectiles. The method is based upon impact parameter close coupling with pseudostates. Examples from antiproton impact ionization are shown.

  20. Experiments using coincidence methods

    International Nuclear Information System (INIS)

    Anwar Dhani.

    1978-01-01

    Experiments on γ spectroscopy using the simple coincidence techniques, including investigation of angular distribution of γ radiation from annihilation process in decay of Na 22 , γ - γ angular correlation technique in decay of Co 60 , decay scheme study of Bi 207 and life time measurement of nuclear Pb 207 excited state have been carried out. (author)

  1. Utility of electronic hand hygiene counting devices for measuring physicians' hand hygiene adherence applied to outpatient settings.

    Science.gov (United States)

    Arai, Akie; Tanabe, Masaki; Nakamura, Akiko; Yamasaki, Daisuke; Muraki, Yuichi; Kaneko, Toshihiro; Kadowaki, Ayako; Ito, Masaaki

    2016-12-01

    Our objectives were to evaluate the utility of electronic hand hygiene counting devices in outpatient settings and the impact of results feedback on physicians' hand hygiene behaviors. We installed 130 electronic hand hygiene counting devices in our redesigned outpatient department. We remotely monitored physicians' hand hygiene practices during outpatient examinations and calculated the adherence rate as follows: number of hand hygiene counts divided by the number of outpatients examined multiplied by 100. Physician individual adherence rates were also classified into 4 categories. Two hundred and eighty physicians from 28 clinical departments were monitored for 3 months. The overall hand hygiene adherence rate was 10.7% at baseline, which improved significantly after feedback to 18.2% in the third month. Of the clinical departments, 78.6% demonstrated significant improvement in hand hygiene compliance. The change in the percentage of physicians in each category before and after feedback were as follows: very low (84.3% to 72.1%), low (8.6% to 14.3%), moderate (2.9% to 8.9%), and high (4.3% to 4.6%), from the first to third month, respectively. Based on category assessment, 17.1% of physicians were classified as responders. Physicians' adherence to hand hygiene practices during outpatient examinations was successfully monitored remotely using electronic counting devices. Audit and feedback of adherence data may have a positive impact on physicians' hand hygiene compliance. Copyright © 2016 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  2. Compton suppression gamma-counting: The effect of count rate

    Science.gov (United States)

    Millard, H.T.

    1984-01-01

    Past research has shown that anti-coincidence shielded Ge(Li) spectrometers enhanced the signal-to-background ratios for gamma-photopeaks, which are situated on high Compton backgrounds. Ordinarily, an anti- or non-coincidence spectrum (A) and a coincidence spectrum (C) are collected simultaneously with these systems. To be useful in neutron activation analysis (NAA), the fractions of the photopeak counts routed to the two spectra must be constant from sample to sample to variations must be corrected quantitatively. Most Compton suppression counting has been done at low count rate, but in NAA applications, count rates may be much higher. To operate over the wider dynamic range, the effect of count rate on the ratio of the photopeak counts in the two spectra (A/C) was studied. It was found that as the count rate increases, A/C decreases for gammas not coincident with other gammas from the same decay. For gammas coincident with other gammas, A/C increases to a maximum and then decreases. These results suggest that calibration curves are required to correct photopeak areas so quantitative data can be obtained at higher count rates. ?? 1984.

  3. Coincidence summing corrections for positron emitters in germanium gamma spectrometry

    International Nuclear Information System (INIS)

    Richardson, A.E.; Sallee, W.W.; New Mexico State Univ., Las Cruces

    1990-01-01

    For positron emitters, 511 keV annihilation quanta are in coincidence with other gamma rays in the decay scheme. If the positrons are not localized at the point of decay, annihilation quanta will be produced at a site some distance from the point of emission. The magnitude of the summing coincidence effect will depend upon the position of annihilation. A method for determining the magnitude of the summing effect for a single gamma of energy E in coincidence with the annihilation gammas from non-localized positrons has been developed which makes use of the counting data for the full energy peaks for both the gamma ray (E) and the 511 keV annihilation gammas. With this data and efficiency calibration data one can determine the average total efficiency for the annihilation positions from which 511 keV gammas originate, and thereby obtain the summing correction factor, SCF, for gamma ray (E). Application of the method to a 22 Na NIST standard gave excellent agreement of observed emission rates for the 1275 keV gamma with the NIST value for wide ranging degrees of positron localization having summing correction factors ranging from 1.021 to 1.505. The method was also applied successfully to 58 Co in neutron-irradiated nickel foils. The method shows promise as a check on the accuracy of the efficiency calibration for a particular detector geometry at the 511 keV energy and energies for other gammas associated with positron emission. (orig.)

  4. Prospects in coincidence experiments

    International Nuclear Information System (INIS)

    Laget, J.M.

    1984-01-01

    The sensitivity of virtual photons to the local variations of the charge and magnetization densities is exploited to study the short-range part of the nucleon-nucleon interaction inside the nucleus. The possibility of varying energy, squared mass and longitudinal polarization of the photons independently enables us to disentangle the mechanisms related to the internal structure of the nucleon (e.g. quark interchange) and the contribution due to meson exchange. Coincidence experiments of the type (e,e'N) and (e,e'NN) are performed to suppress the meson contribution to the longitudinal part of the quasi-elastic peak. Four typical examples of coincidence experiments induced by virtual photons are discussed: experiments (1) on the spectroscopic structure of the quasi-elastic peak and the problem of deep lying hole states; (2) on the structure of the continuum; (3) on the low energy side of the quasi-elastic peak; and finally a three-arm coincidence experiment. (Auth.)

  5. Coincidence corrections for a multi-detector gamma spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Britton, R., E-mail: r.britton@surrey.ac.uk [University of Surrey, Guildford GU2 7XH (United Kingdom); AWE, Aldermaston, Reading, Berkshire RG7 4PR (United Kingdom); Burnett, J.L.; Davies, A.V. [AWE, Aldermaston, Reading, Berkshire RG7 4PR (United Kingdom); Regan, P.H. [University of Surrey, Guildford GU2 7XH (United Kingdom)

    2015-01-01

    List-mode data acquisition has been utilised in conjunction with a high-efficiency γ–γ coincidence system, allowing both the energetic and temporal information to be retained for each recorded event. Collected data is re-processed multiple times to extract any coincidence information from the γ-spectroscopy system, correct for the time-walk of low-energy events, and remove accidental coincidences from the projected coincidence spectra. The time-walk correction has resulted in a reduction in the width of the coincidence delay gate of 18.4±0.4%, and thus an equivalent removal of ‘background’ coincidences. The correction factors applied to ∼5.6% of events up to ∼500 keV for a combined {sup 137}Cs and {sup 60}Co source, and are crucial for accurate coincidence measurements of low-energy events that may otherwise be missed by a standard delay gate. By extracting both the delay gate and a representative ‘background’ region for the coincidences, a coincidence background subtracted spectrum is projected from the coincidence matrix, which effectively removes ∼100% of the accidental coincidences (up to 16.6±0.7% of the total coincidence events seen during this work). This accidental-coincidence removal is crucial for accurate characterisation of the events seen in coincidence systems, as without this correction false coincidence signatures may be incorrectly interpreted.

  6. A portable neutron coincidence counter

    Energy Technology Data Exchange (ETDEWEB)

    Peurrung, A.J.; Bowyer, S.M.; Craig, R.A.; Dudder, G.B.; Knopf, M.A.; Panisko, M.E.; Reeder, P.L.; Stromswold, D.C.; Sunberg, D.S.

    1996-11-01

    Pacific Northwest National Laboratory has designed and constructed a prototype portable neutron coincidence counter intended for use in a variety of applications, such as the verification and inspection of weapons components, safety measurements for novel and challenging situations, portable portal deployment to prevent the transportation of fissile materials, uranium enrichment measurements in hard-to-reach locations, waste assays for objects that cannot be measured by existing measurement systems, and decontamination and decommissioning. The counting system weighs less than 40 kg and is composed of parts each weighing no more than 5 kg. In addition, the counter`s design is sufficiently flexible to allow rapid, reliable assembly around containers of nearly arbitrary size and shape. The counter is able to discern the presence of 1 kg of weapons-grade plutonium within an ALR-8 (30-gal drum) in roughly 100 seconds and 10 g in roughly 1000 seconds. The counter`s electronics are also designed for maximum adaptability, allowing operation under a wide variety of circumstances, including exposure to gamma-ray fields of 1 R/h. This report provides a detailed review of the design and construction process. Finally, preliminary experimental measurements that confirm the performance capabilities of this counter are discussed. 6 refs., 18 figs., 3 tabs.

  7. Standardization of I-125. Sum-Peak Coincidence Counting

    International Nuclear Information System (INIS)

    Grau Carles, A.; Grau Malonda, A.

    2011-01-01

    I-125 is a nuclide which presents difficulties for standardization. The sum-peak method is one of the procedures used to standardize this radionuclide. Initially NaI (Tl)detectors and then the semiconductor detectors with higher resolution have been used.This paper describes the different methods based on the sum-peak procedure and the different expressions used to calculate the activity are deduced. We describe a general procedure for obtaining all of the above equations and many more. We analyze the influence of uncertainties in the used parameters in the uncertainty of the activity. We give a complete example of the transmission of uncertainty and the effects of correlations in the uncertainty of the activity of the sample. High-resolution spectra show an unresolved doublet of 62.0 keV and 62.8 keV. The paper presents two approaches to solve this problem. One is based on the calculation of area ratio and the sum of peak areas obtained from atomic and nuclear data, in the other we modify the equations so that the sum of the peak areas doublet, rather than its components, is present. (Author) 19 refs.

  8. Standardization of I-125. Sum-Peak Coincidence Counting

    Energy Technology Data Exchange (ETDEWEB)

    Grau Carles, A.; Grau Malonda, A.

    2011-07-01

    I-125 is a nuclide which presents difficulties for standardization. The sum-peak method is one of the procedures used to standardize this radionuclide. Initially NaI (Tl)detectors and then the semiconductor detectors with higher resolution have been used.This paper describes the different methods based on the sum-peak procedure and the different expressions used to calculate the activity are deduced. We describe a general procedure for obtaining all of the above equations and many more. We analyze the influence of uncertainties in the used parameters in the uncertainty of the activity. We give a complete example of the transmission of uncertainty and the effects of correlations in the uncertainty of the activity of the sample. High-resolution spectra show an unresolved doublet of 62.0 keV and 62.8 keV. The paper presents two approaches to solve this problem. One is based on the calculation of area ratio and the sum of peak areas obtained from atomic and nuclear data, in the other we modify the equations so that the sum of the peak areas doublet, rather than its components, is present. (Author) 19 refs.

  9. Design and development of VHDL based IP core for coincidence analyzer for FPGA based TDCR system

    International Nuclear Information System (INIS)

    Agarwal, Shivam; Gupta, Ashutosh; Chaudhury, Probal; Sharma, M.K.; Kulkarni, M.S.

    2018-01-01

    The coincidence counting technique is used in activity measurement methods to determine the activity of radionuclide e.g. 4πβ-γ method and Triple to Double Coincidence Ratio (TDCR) method etc. The 4πβ-γ method requires two inputs Coincidence Analyzer (CA) whereas; TDCR method requires three inputs CA. A VHDL (Very High Speed Integrated Circuit Hardware Description Language) based IP (Intellectual Property) core for coincidence analyzer has been designed and implemented in FPGA (Field Programmable Gate Array) for TDCR system. The developed IP not only facilitates the coincidence counting of three channels simultaneously but also provides an extendable dead time feature

  10. Triple-coincidence with automatic chance coincidence correction

    International Nuclear Information System (INIS)

    Chase, R.L.

    1975-05-01

    The chance coincidences in a triple-coincidence circuit are of two types--partially correlated and entirely uncorrelated. Their relative importance depends on source strength and source and detector geometry so that the total chance correction cannot, in general, be calculated. The system described makes use of several delays and straightforward integrated circuit logic to provide independent evaluation of the two components of the chance coincidence rate. (auth)

  11. Active method of neutron time correlation coincidence measurement to authenticate mass and enrichment of uranium metal

    International Nuclear Information System (INIS)

    Zhang Songbai; Wu Jun; Zhu Jianyu; Tian Dongfeng; Xie Dong

    2011-01-01

    The active methodology of time correlation coincidence measurement of neutron is an effective verification means to authenticate uranium metal. A collimated 252 Cf neutron source was used to investigate mass and enrichment of uranium metal through the neutron transport simulation for different enrichments and different masses of uranium metal, then time correlation coincidence counts of them were obtained. By analyzing the characteristic of time correlation coincidence counts, the monotone relationships were founded between FWTH of time correlation coincidence and multiplication factor, between the total coincidence counts in FWTH for time correlation coincidence and mass of 235 U multiplied by multiplication factor, and between the ratio of neutron source penetration and mass of uranium metal. Thus the methodology to authenticate mass and enrichment of uranium metal was established with time correlation coincidence by active neutron investigation. (authors)

  12. RBC count

    Science.gov (United States)

    ... by kidney disease) RBC destruction ( hemolysis ) due to transfusion, blood vessel injury, or other cause Leukemia Malnutrition Bone ... slight risk any time the skin is broken) Alternative Names Erythrocyte count; Red blood cell count; Anemia - RBC count Images Blood test ...

  13. Introduction to Neutron Coincidence Counter Design Based on Boron-10

    Energy Technology Data Exchange (ETDEWEB)

    Kouzes, Richard T.; Ely, James H.; Lintereur, Azaree T.; Siciliano, Edward R.

    2012-01-22

    The Department of Energy Office of Nonproliferation Policy (NA-241) is supporting the project 'Coincidence Counting With Boron-Based Alternative Neutron Detection Technology' at Pacific Northwest National Laboratory (PNNL) for development of an alternative neutron coincidence counter. The goal of this project is ultimately to design, build and demonstrate a boron-lined proportional tube based alternative system in the configuration of a coincidence counter. This report, providing background information for this project, is the deliverable under Task 1 of the project.

  14. Echoes from birth--mutual benefits for physical and forensic anthropology by applying increment counts in enamel of deciduous teeth for aging.

    Science.gov (United States)

    Witzel, Carsten

    2014-01-01

    The present study aims to compare metrical and morphological features of skeletal and dental development in two skeletons of very young infants from different archeological sites in Syria with the results of the microscopic approach of age-at-death estimation based on the neonatal line (NNL). Here, the presence ofa NNL is used as an indicator of birth survival and the duration of the lifespan post partum is assessed by counting prism cross-striations (PCS) external to the NNL. In the literature, PCS have been determined to represent a circadian rhythm in human enamel formation. For both individuals, consistent results in terms of the presence of a NNL and the counts of prism cross-striations could have been obtained. In the younger individual evidence of a postnatal age at death of less than two weeks was documented. This study demonstrates that the use of the NNL as an individual landmark without the need for the reference to growth standards enables an estimation of age at death on skeletal remains of infants within much narrower ranges compared with metrical and morphological analyses. To date, presence of a NNL is the only way of documenting birth survival in skeletons of perinatal individuals. This method can be applied to forensic and bioarcheological skeletal material.

  15. A training and educational tool for neutron coincidence measurements

    International Nuclear Information System (INIS)

    Huszti, J.; Bagi, J.; Langner, D.

    2009-01-01

    Neutron coincidence counting techniques are widely used for nuclear safeguards inspection. They are based on the detection of time correlated neutrons created from spontaneous or induced fission of plutonium and some other actinides. IAEA inspectors are trained to know and to use this technique, but it is not easy to illustrate and explain the basics of the neutron coincidence counting. The traditional shift registers or multiplicity counters give only multiplicity distributions and the singles, doubles and triples count rates. Using the list mode method for the recording and evaluation of neutron coincidence data makes it easier to teach this technique. List mode acquisition is a relatively new way to collect data in neutron coincidence counting. It is based on the recording of the follow-up times of neutron pulses originating from a neutron detector into a file. The recorded pulse train can be evaluated with special software after the measurement. Hardware and software for list mode neutron coincidence acquisition have been developed in the Institute of Isotopes and is called a Pulse Train Reader. A system called Virtual Source for replaying pulse trains registered with the list mode device has also been developed. The list mode device and the pulse train 're-player' together build a good educational tool for teaching the basics of neutron coincidence counting. Some features of the follow-up time, multiplicity and Rossi-alpha distributions can be well demonstrated by replaying artificially generated or pre-recorded pulse trains. The choice of real sources is stored on DVD. There is no need to transport and maintain real sources for the training. Virtual sources also give the possibility of investigating rare sources that trainees would not have access to otherwise. (authors)

  16. Counting Possibilia

    Directory of Open Access Journals (Sweden)

    Alfredo Tomasetta

    2010-06-01

    Full Text Available Timothy Williamson supports the thesis that every possible entity necessarily exists and so he needs to explain how a possible son of Wittgenstein’s, for example, exists in our world:he exists as a merely possible object (MPO, a pure locus of potential. Williamson presents a short argument for the existence of MPOs: how many knives can be made by fitting together two blades and two handles? Four: at the most two are concrete objects, the others being merely possible knives and merely possible objects. This paper defends the idea that one can avoid reference and ontological commitment to MPOs. My proposal is that MPOs can be dispensed with by using the notion of rules of knife-making. I first present a solution according to which we count lists of instructions - selected by the rules - describing physical combinations between components. This account, however, has its own difficulties and I eventually suggest that one can find a way out by admitting possible worlds, entities which are more commonly accepted - at least by philosophers - than MPOs. I maintain that, in answering Williamson’s questions, we count classes of physically possible worlds in which the same instance of a general rule is applied.

  17. A {beta} - {gamma} coincidence; Metodo de coincidencias {beta} - {gamma}

    Energy Technology Data Exchange (ETDEWEB)

    Agullo, F

    1960-07-01

    A {beta} - {gamma} coincidence method for absolute counting is given. The fundamental principles are revised and the experimental part is detailed. The results from {sup 1}98 Au irradiated in the JEN 1 Swimming pool reactor are given. The maximal accuracy is 1 per cent. (Author) 11 refs.

  18. Counting carbohydrates

    Science.gov (United States)

    Carb counting; Carbohydrate-controlled diet; Diabetic diet; Diabetes-counting carbohydrates ... Many foods contain carbohydrates (carbs), including: Fruit and fruit juice Cereal, bread, pasta, and rice Milk and milk products, soy milk Beans, legumes, ...

  19. Channel coincidence counter: version 1

    International Nuclear Information System (INIS)

    Krick, M.S.; Menlove, H.O.

    1980-06-01

    A thermal neutron coincidence counter has been designed for the assay of fast critical assembly fuel drawers and plutonium-bearing fuel rods. The principal feature of the detector is a 7-cm by 7-cm by 97-cm detector channel, which provides a uniform neutron detection efficiency of 16% along the central 40 cm of the channel. The electronics system is identical to that used for the High-Level Neutron Coincidence Counter

  20. Permutational symmetries for coincidence rates in multimode multiphotonic interferometry

    Science.gov (United States)

    Khalid, Abdullah; Spivak, Dylan; Sanders, Barry C.; de Guise, Hubert

    2018-06-01

    We obtain coincidence rates for passive optical interferometry by exploiting the permutational symmetries of partially distinguishable input photons, and our approach elucidates qualitative features of multiphoton coincidence landscapes. We treat the interferometer input as a product state of any number of photons in each input mode with photons distinguished by their arrival time. Detectors at the output of the interferometer count photons from each output mode over a long integration time. We generalize and prove the claim of Tillmann et al. [Phys. Rev. X 5, 041015 (2015), 10.1103/PhysRevX.5.041015] that coincidence rates can be elegantly expressed in terms of immanants. Immanants are functions of matrices that exhibit permutational symmetries and the immanants appearing in our coincidence-rate expressions share permutational symmetries with the input state. Our results are obtained by employing representation theory of the symmetric group to analyze systems of an arbitrary number of photons in arbitrarily sized interferometers.

  1. Recovery and normalization of triple coincidences in PET

    Energy Technology Data Exchange (ETDEWEB)

    Lage, Eduardo, E-mail: elage@mit.edu; Parot, Vicente; Dave, Shivang R.; Herraiz, Joaquin L. [Madrid-MIT M+Visión Consortium, Massachusetts Institute of Technology, Cambridge, Massachusetts 02139 (United States); Moore, Stephen C.; Sitek, Arkadiusz; Park, Mi-Ae [Division of Nuclear Medicine, Department of Radiology, Harvard Medical School and Brigham and Women’s Hospital, Boston, Massachusetts 02115 (United States); Udías, Jose M. [Grupo de Física Nuclear, Departamento de Física Atómica Molecular y Nuclear, Universidad Complutense de Madrid, CEI Moncloa, Madrid 28040 (Spain); Vaquero, Juan J. [Departamento de Ingeniería Biomédica e Ingeniería Aeroespacial, Universidad Carlos III de Madrid, Leganés 28911 (Spain)

    2015-03-15

    Purpose: Triple coincidences in positron emission tomography (PET) are events in which three γ-rays are detected simultaneously. These events, though potentially useful for enhancing the sensitivity of PET scanners, are discarded or processed without special consideration in current systems, because there is not a clear criterion for assigning them to a unique line-of-response (LOR). Methods proposed for recovering such events usually rely on the use of highly specialized detection systems, hampering general adoption, and/or are based on Compton-scatter kinematics and, consequently, are limited in accuracy by the energy resolution of standard PET detectors. In this work, the authors propose a simple and general solution for recovering triple coincidences, which does not require specialized detectors or additional energy resolution requirements. Methods: To recover triple coincidences, the authors’ method distributes such events among their possible LORs using the relative proportions of double coincidences in these LORs. The authors show analytically that this assignment scheme represents the maximum-likelihood solution for the triple-coincidence distribution problem. The PET component of a preclinical PET/CT scanner was adapted to enable the acquisition and processing of triple coincidences. Since the efficiencies for detecting double and triple events were found to be different throughout the scanner field-of-view, a normalization procedure specific for triple coincidences was also developed. The effect of including triple coincidences using their method was compared against the cases of equally weighting the triples among their possible LORs and discarding all the triple events. The authors used as figures of merit for this comparison sensitivity, noise-equivalent count (NEC) rates and image quality calculated as described in the NEMA NU-4 protocol for the assessment of preclinical PET scanners. Results: The addition of triple-coincidence events with the

  2. Recovery and normalization of triple coincidences in PET.

    Science.gov (United States)

    Lage, Eduardo; Parot, Vicente; Moore, Stephen C; Sitek, Arkadiusz; Udías, Jose M; Dave, Shivang R; Park, Mi-Ae; Vaquero, Juan J; Herraiz, Joaquin L

    2015-03-01

    Triple coincidences in positron emission tomography (PET) are events in which three γ-rays are detected simultaneously. These events, though potentially useful for enhancing the sensitivity of PET scanners, are discarded or processed without special consideration in current systems, because there is not a clear criterion for assigning them to a unique line-of-response (LOR). Methods proposed for recovering such events usually rely on the use of highly specialized detection systems, hampering general adoption, and/or are based on Compton-scatter kinematics and, consequently, are limited in accuracy by the energy resolution of standard PET detectors. In this work, the authors propose a simple and general solution for recovering triple coincidences, which does not require specialized detectors or additional energy resolution requirements. To recover triple coincidences, the authors' method distributes such events among their possible LORs using the relative proportions of double coincidences in these LORs. The authors show analytically that this assignment scheme represents the maximum-likelihood solution for the triple-coincidence distribution problem. The PET component of a preclinical PET/CT scanner was adapted to enable the acquisition and processing of triple coincidences. Since the efficiencies for detecting double and triple events were found to be different throughout the scanner field-of-view, a normalization procedure specific for triple coincidences was also developed. The effect of including triple coincidences using their method was compared against the cases of equally weighting the triples among their possible LORs and discarding all the triple events. The authors used as figures of merit for this comparison sensitivity, noise-equivalent count (NEC) rates and image quality calculated as described in the NEMA NU-4 protocol for the assessment of preclinical PET scanners. The addition of triple-coincidence events with the authors' method increased peak

  3. Corrections for the effects of accidental coincidences, Compton scatter, and object size in positron emission mammography (PEM) imaging

    Science.gov (United States)

    Raylman, R. R.; Majewski, S.; Wojcik, R.; Weisenberger, A. G.; Kross, B.; Popov, V.

    2001-06-01

    Positron emission mammography (PEM) has begun to show promise as an effective method for the detection of breast lesions. Due to its utilization of tumor-avid radiopharmaceuticals labeled with positron-emitting radionuclides, this technique may be especially useful in imaging of women with radiodense or fibrocystic breasts. While the use of these radiotracers affords PEM unique capabilities, it also introduces some limitations. Specifically, acceptance of accidental and Compton-scattered coincidence events can decrease lesion detectability. The authors studied the effect of accidental coincidence events on PEM images produced by the presence of /sup 18/F-Fluorodeoxyglucose in the organs of a subject using an anthropomorphic phantom. A delayed-coincidence technique was tested as a method for correcting PEM images for the occurrence of accidental events. Also, a Compton scatter correction algorithm designed specifically for PEM was developed and tested using a compressed breast phantom. Finally, the effect of object size on image counts and a correction for this effect were explored. The imager used in this study consisted of two PEM detector heads mounted 20 cm apart on a Lorad biopsy apparatus. The results demonstrated that a majority of the accidental coincidence events (/spl sim/80%) detected by this system were produced by radiotracer uptake in the adipose and muscle tissue of the torso. The presence of accidental coincidence events was shown to reduce lesion detectability. Much of this effect was eliminated by correction of the images utilizing estimates of accidental-coincidence contamination acquired with delayed coincidence circuitry built into the PEM system. The Compton scatter fraction for this system was /spl sim/14%. Utilization of a new scatter correction algorithm reduced the scatter fraction to /spl sim/1.5%. Finally, reduction of count recovery due to object size was measured and a correction to the data applied. Application of correction techniques

  4. 3D Silicon Coincidence Avalanche Detector (3D-SiCAD) for charged particle detection

    Science.gov (United States)

    Vignetti, M. M.; Calmon, F.; Pittet, P.; Pares, G.; Cellier, R.; Quiquerez, L.; Chaves de Albuquerque, T.; Bechetoille, E.; Testa, E.; Lopez, J.-P.; Dauvergne, D.; Savoy-Navarro, A.

    2018-02-01

    Single-Photon Avalanche Diodes (SPADs) are p-n junctions operated in Geiger Mode by applying a reverse bias above the breakdown voltage. SPADs have the advantage of featuring single photon sensitivity with timing resolution in the picoseconds range. Nevertheless, their relatively high Dark Count Rate (DCR) is a major issue for charged particle detection, especially when it is much higher than the incoming particle rate. To tackle this issue, we have developed a 3D Silicon Coincidence Avalanche Detector (3D-SiCAD). This novel device implements two vertically aligned SPADs featuring on-chip electronics for the detection of coincident avalanche events occurring on both SPADs. Such a coincidence detection mode allows an efficient discrimination of events related to an incoming charged particle (producing a quasi-simultaneous activation of both SPADs) from dark counts occurring independently on each SPAD. A 3D-SiCAD detector prototype has been fabricated in CMOS technology adopting a 3D flip-chip integration technique, and the main results of its characterization are reported in this work. The particle detection efficiency and noise rejection capability for this novel device have been evaluated by means of a β- strontium-90 radioactive source. Moreover the impact of the main operating parameters (i.e. the hold-off time, the coincidence window duration, the SPAD excess bias voltage) over the particle detection efficiency has been studied. Measurements have been performed with different β- particles rates and show that a 3D-SiCAD device outperforms single SPAD detectors: the former is indeed capable to detect particle rates much lower than the individual DCR observed in a single SPAD-based detectors (i.e. 2 to 3 orders of magnitudes lower).

  5. On neutron activation analysis with γγ coincidence spectrometry

    International Nuclear Information System (INIS)

    Zeisler, Rolf; Danyal Turkoglu; Ibere Souza Ribeiro Junior; Shetty, M.G.

    2017-01-01

    A new γγ coincidence system has been set up at NIST. It is operated with a digital data finder supported by new software developed at NIST. The system is used to explore possible enhancements in instrumental neutron activation analysis (INAA) and study applicability to neutron capture prompt gamma activation analysis (PGAA). The performance of the system is tested with certified reference materials for efficiency calibration and quantitative performance. Comparisons of INAA results based on conventional gamma-ray spectrometry data with INAA results based on coincidence data obtained from the same samples show improvements in the counting uncertainties and demonstrates the quantitative accuracy of the new system. (author)

  6. Secondary electron emission studied by secondary electron energy loss coincidence spectroscopy (SE2ELCS)

    International Nuclear Information System (INIS)

    Khalid, R.

    2013-01-01

    Emission of secondary electrons is of importance in many branches of fundamental and applied science. It is widely applied in the electron microscope for the investigation of the structure and electronic state of solid surfaces and particle detection in electron multiplier devices, and generally it is related to the energy dissipation of energetic particles moving inside a solid. The process of secondary electron emission is a complex physical phenomenon, difficult to measure experimentally and treat theoretically with satisfactory accuracy. The secondary electron spectrum measured with single electron spectroscopy does not provide detailed information of the energy loss processes responsible for the emission of secondary electrons. This information can be accessed when two correlated electron pairs are measured in coincidence and the pair consists of a backscattered electron after a given energy loss and a resulting emitted secondary electron. To investigate the mechanisms responsible for the emission of secondary electrons, a reflection (e,2e) coincidence spectrometer named Secondary Electron Electron Energy Loss Coincidence Spectrometer (SE2ELCS) has been developed in the framework of this thesis which allows one to uncover the relation between the features in the spectra which are due to energy losses and true secondary electron emission structures. The correlated electron pairs are measured with a hemispherical mirror analyzer (HMA) and a time of flight analyzer (TOF) by employing a continuous electron beam. An effort has been made to increase the coincidence count rate by increasing the effective solid angle of the TOF analyzer and optimizing the experimental parameters to get optimum energy resolution. Double differential coincidence spectra for a number of materials namely, nearly free electron metals (Al, Si), noble metals (Ag, Au, Cu, W) and highly oriented pyrolytic graphite (HOPG) have been measured using this coincidence spectrometer. The

  7. In-situ fluorescence hybridization applied to biological dosimetry: contribution of automation to the counting of radio-induced chromosome aberrations

    International Nuclear Information System (INIS)

    Germain Thomas Roy, Laurence

    1999-01-01

    The frequency of chromosome aberrations on peripheral blood lymphocytes is a dose indicator in the case of ionizing radiations over-exposure. Stable chromosome aberrations (translocations, insertions) are visualized after labelling of some chromosomes using the fluorescence in-situ hybridization (FISH). The study of the use of the FISH technique in biological dosimetry is done with dose-effect curves. It seems that a bias is introduced during the observation of chromosome aberrations involving only 3 pairs of chromosomes. In order to avoid this bias, it would be useful to test the feasibility of using the multi-FISH technique in biological dosimetry. Moreover, this type of chromosome aberration changes with the type of irradiation. It is thus important to define the aberrations to be considered when the FISH technique is used. In order to reduce the time of image analysis, the CYTOGEN system, developed by IMSTAR company (Paris, France) has been adapted to the needs of biological dosimetry. This system allows to localize automatically the metaphases on the slide, which reduces the observation time by 2 or 4. An automatic detection protocol for chromosome aberrations has been implemented. It comprises the image capture, the contours detection and the classification of some chromosome aberrations. The different steps of this protocol have been tested in order to check that no bias is introduced by the automation. However, because radio-induced aberrations are rare events, it seems that a totally automatic system is not foreseeable. A semi-automatic analysis is more suitable. The use of the Slit-Scan technology (Laboratory of applied physics, Heidelberg, Germany) in biological dosimetry has been studied too. This technique allows to analyze rapidly a huge number of chromosomes. A good correlation has been observed between the dicentric frequency measured automatically and by manual counting. The system is under development and should be adapted to the detection of

  8. Video Histories, Memories, and Coincidences

    DEFF Research Database (Denmark)

    Kacunko, Slavko

    2012-01-01

    Looping images allows us to notice things that we have never noticed before. Looping a small but exquisite selection of the video tapes of Marcel Odenbach, Dieter Kiessling and Matthias Neuenhofer may allow the discovering of Histories, Coincidences, and Infinitesimal Aesthetics inscribed...

  9. Description and performance characteristics for the neutron Coincidence Collar for the verification of reactor fuel assemblies

    International Nuclear Information System (INIS)

    Menlove, H.O.

    1981-08-01

    An active neutron interrogation method has been developed for the measurement of 235 U content in fresh fuel assemblies. The neutron Coincidence Collar uses neutron interrogation with an AmLi neutron source and coincidence counting the induced fission reaction neutrons from the 235 U. This manual describes the system components, operation, and performance characteristics. Applications of the Coincidence Collar to PWR and BWR types of reactor fuel assemblies are described

  10. Counting cormorants

    DEFF Research Database (Denmark)

    Bregnballe, Thomas; Carss, David N; Lorentsen, Svein-Håkon

    2013-01-01

    This chapter focuses on Cormorant population counts for both summer (i.e. breeding) and winter (i.e. migration, winter roosts) seasons. It also explains differences in the data collected from undertaking ‘day’ versus ‘roost’ counts, gives some definitions of the term ‘numbers’, and presents two...

  11. Development of Coincidence Method for Determination Thermal Neutron Flux on RSG-GAS

    International Nuclear Information System (INIS)

    Bakhri, Syaiful; Hamzah, Amir

    2004-01-01

    The research to develop detection radiation system using coincidence method has been done to determine thermal neutron flux in RS1 and RS2 irradiation facilities RSG-GAS. At this research has arranged beta-gamma coincidence equipment system and parameter of measurement according to Au-198 beta-gamma spectrum. Gold foils that have irradiated for period of time, counted, and the activities of radiation is analyzed to get neutron flux. Result of research indicate that systems measurement of absolute activity with gamma beta coincidence method functioning well and can be applied at activity measurement of gold foil for irradiation facility characterization. The results show that thermal neutron flux in RS1 and RS2, respectively is 2.007E+12 n/cm 2 s and 2.147E+12 n/cm 2 s. To examine the system performance, the result was compared to measure activity using high resolution of Hp Ge detector and achieved discrepancy is about 1.26% and 6.70%. (author)

  12. Tower counts

    Science.gov (United States)

    Woody, Carol Ann; Johnson, D.H.; Shrier, Brianna M.; O'Neal, Jennifer S.; Knutzen, John A.; Augerot, Xanthippe; O'Neal, Thomas A.; Pearsons, Todd N.

    2007-01-01

    Counting towers provide an accurate, low-cost, low-maintenance, low-technology, and easily mobilized escapement estimation program compared to other methods (e.g., weirs, hydroacoustics, mark-recapture, and aerial surveys) (Thompson 1962; Siebel 1967; Cousens et al. 1982; Symons and Waldichuk 1984; Anderson 2000; Alaska Department of Fish and Game 2003). Counting tower data has been found to be consistent with that of digital video counts (Edwards 2005). Counting towers do not interfere with natural fish migration patterns, nor are fish handled or stressed; however, their use is generally limited to clear rivers that meet specific site selection criteria. The data provided by counting tower sampling allow fishery managers to determine reproductive population size, estimate total return (escapement + catch) and its uncertainty, evaluate population productivity and trends, set harvest rates, determine spawning escapement goals, and forecast future returns (Alaska Department of Fish and Game 1974-2000 and 1975-2004). The number of spawning fish is determined by subtracting subsistence, sport-caught fish, and prespawn mortality from the total estimated escapement. The methods outlined in this protocol for tower counts can be used to provide reasonable estimates ( plus or minus 6%-10%) of reproductive salmon population size and run timing in clear rivers. 

  13. Comparative study of chance coincidence correction in measuring 223Ra and 224Ra by delay coincidence method

    International Nuclear Information System (INIS)

    Yan Yongjun; Huang Derong; Zhou Jianliang; Qiu Shoukang

    2013-01-01

    The delay coincidence measurement of 220 Rn and 219 Rn has been proved to be a valid indirect method for measuring 224 Ra and 223 Ra extracted from natural water, which can provide valuable information on estuarine/ocean mixing, submarine groundwater discharge, and water/soil interactions. In practical operation chance coincidence correction must be considered, mostly Moore's correction method, but Moore's and Giffin's methods were incomplete in some ways. In this paper the modification (method 1) and a new chance coincidence correction formula (method 2) were provided. Experiments results are presented to demonstrate the conclusions. The results show that precision is improved while counting rate is less than 70 min- 1 . (authors)

  14. Multiple channel programmable coincidence counter

    Science.gov (United States)

    Arnone, Gaetano J.

    1990-01-01

    A programmable digital coincidence counter having multiple channels and featuring minimal dead time. Neutron detectors supply electrical pulses to a synchronizing circuit which in turn inputs derandomized pulses to an adding circuit. A random access memory circuit connected as a programmable length shift register receives and shifts the sum of the pulses, and outputs to a serializer. A counter is input by the adding circuit and downcounted by the seralizer, one pulse at a time. The decoded contents of the counter after each decrement is output to scalers.

  15. Numerical coincidences and 'tuning' in cosmology

    OpenAIRE

    Rees, Martin J.

    2004-01-01

    Fred Hoyle famously drew attention to the significance of apparent coincidences in the energy levels of the carbon and oxygen nucleus. This paper addresses the possible implications of other coincidences in cosmology.

  16. Coincident photoelectron spectroscopy on superconductors

    International Nuclear Information System (INIS)

    Voss, Stefan

    2011-01-01

    Aim of the performed experiments of this thesis was to attempt to detect Cooper pairs as carriers of the superconducting current directly by means of the photoelectric effect. The method of the coincident photoelectron spectroscopy aims thereby at the detection of two coherently emitted electrons by the interaction with a photon. Because electrostatic analyzers typically cover only a very small spatial angle, which goes along with very low coincidence rates, in connection with this thesis a time-of-flight projection system has been developed, which maps nearly the whole spatial angle on a position-resolving detector. The pulsed light source in form of special synchrotron radiation necessary for the measurement has been adjusted so weak, that only single photons could arrive at the sample. Spectroscoped were beside test measurements on silver layers both a lead monocrystal as representative of the classical BCS superconductors and monocrystalline Bi 2 Sr 2 CaCu 2 O 8 from the family of the high-temperature superconductors. With excitation energies up to 40 eV could be shown that sufficiently smooth and clean surfaces in the superconducting phase exhibit within the resolving power of about 0.5 eV no recognizable differences in comparison to the normally conducting phase. Beside these studies furthermore the simple photoemission at the different samples and especially in the case of the lead crystal is treated, because here no comparable results are known. Thereby the whole momentum space is discussed and the Fermi surface established as three-dimensional model, by means of which the measurement results are discussed. in the theoretical descriptions different models for the Cooper-pair production are presented, whereby to the momentum exchange with the crystal a special role is attributed, because this can only occur in direct excitations via discrete lattice vectors.

  17. Simulation approach to coincidence summing in {gamma}-ray spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Dziri, S., E-mail: samir.dziri@iphc.cnrs.fr [Groupe RaMsEs, Institut Pluridisciplinaire Hubert Curien (IPHC), University of Strasbourg, CNRS, IN2P3, UMR 7178, 23 rue de Loess, BP 28, 67037 Strasbourg Cedex 2 (France); Nourreddine, A.; Sellam, A.; Pape, A.; Baussan, E. [Groupe RaMsEs, Institut Pluridisciplinaire Hubert Curien (IPHC), University of Strasbourg, CNRS, IN2P3, UMR 7178, 23 rue de Loess, BP 28, 67037 Strasbourg Cedex 2 (France)

    2012-07-15

    Some of the radionuclides used for efficiency calibration of a HPGe spectrometer are subject to coincidence-summing (CS) and account must be taken of the phenomenon to obtain quantitative results when counting samples to determine their activity. We have used MCNPX simulations, which do not take CS into account, to obtain {gamma}-ray peak intensities that were compared to those observed experimentally. The loss or gain of a measured peak intensity relative to the simulated peak is attributed to CS. CS correction factors are compared with those of ETNA and GESPECOR. Application to a test sample prepared with known radionuclides gave values close to the published activities. - Highlights: Black-Right-Pointing-Pointer Coincidence summing occurs when the solid angle is increased. Black-Right-Pointing-Pointer The loss of counts gives rise to an approximative efficiency curves, this means a wrong quantitative data. Black-Right-Pointing-Pointer To overcome this problem we need mono-energetic source, otherwise, the MCNPX simulation allows by comparison with the experiment data to get the coincidence summing correction factors. Black-Right-Pointing-Pointer By multiplying these factors by the approximative efficiency, we obtain the accurate efficiency.

  18. Counting probe

    International Nuclear Information System (INIS)

    Matsumoto, Haruya; Kaya, Nobuyuki; Yuasa, Kazuhiro; Hayashi, Tomoaki

    1976-01-01

    Electron counting method has been devised and experimented for the purpose of measuring electron temperature and density, the most fundamental quantities to represent plasma conditions. Electron counting is a method to count the electrons in plasma directly by equipping a probe with the secondary electron multiplier. It has three advantages of adjustable sensitivity, high sensitivity of the secondary electron multiplier, and directional property. Sensitivity adjustment is performed by changing the size of collecting hole (pin hole) on the incident front of the multiplier. The probe is usable as a direct reading thermometer of electron temperature because it requires to collect very small amount of electrons, thus it doesn't disturb the surrounding plasma, and the narrow sweep width of the probe voltage is enough. Therefore it can measure anisotropy more sensitively than a Langmuir probe, and it can be used for very low density plasma. Though many problems remain on anisotropy, computer simulation has been carried out. Also it is planned to provide a Helmholtz coil in the vacuum chamber to eliminate the effect of earth magnetic field. In practical experiments, the measurement with a Langmuir probe and an emission probe mounted to the movable structure, the comparison with the results obtained in reverse magnetic field by using a Helmholtz coil, and the measurement of ionic sound wave are scheduled. (Wakatsuki, Y.)

  19. Coincident Detection Significance in Multimessenger Astronomy

    Science.gov (United States)

    Ashton, G.; Burns, E.; Dal Canton, T.; Dent, T.; Eggenstein, H.-B.; Nielsen, A. B.; Prix, R.; Was, M.; Zhu, S. J.

    2018-06-01

    We derive a Bayesian criterion for assessing whether signals observed in two separate data sets originate from a common source. The Bayes factor for a common versus unrelated origin of signals includes an overlap integral of the posterior distributions over the common-source parameters. Focusing on multimessenger gravitational-wave astronomy, we apply the method to the spatial and temporal association of independent gravitational-wave and electromagnetic (or neutrino) observations. As an example, we consider the coincidence between the recently discovered gravitational-wave signal GW170817 from a binary neutron star merger and the gamma-ray burst GRB 170817A: we find that the common-source model is enormously favored over a model describing them as unrelated signals.

  20. Regular exercise and related factors in patients with Parkinson's disease: Applying zero-inflated negative binomial modeling of exercise count data.

    Science.gov (United States)

    Lee, JuHee; Park, Chang Gi; Choi, Moonki

    2016-05-01

    This study was conducted to identify risk factors that influence regular exercise among patients with Parkinson's disease in Korea. Parkinson's disease is prevalent in the elderly, and may lead to a sedentary lifestyle. Exercise can enhance physical and psychological health. However, patients with Parkinson's disease are less likely to exercise than are other populations due to physical disability. A secondary data analysis and cross-sectional descriptive study were conducted. A convenience sample of 106 patients with Parkinson's disease was recruited at an outpatient neurology clinic of a tertiary hospital in Korea. Demographic characteristics, disease-related characteristics (including disease duration and motor symptoms), self-efficacy for exercise, balance, and exercise level were investigated. Negative binomial regression and zero-inflated negative binomial regression for exercise count data were utilized to determine factors involved in exercise. The mean age of participants was 65.85 ± 8.77 years, and the mean duration of Parkinson's disease was 7.23 ± 6.02 years. Most participants indicated that they engaged in regular exercise (80.19%). Approximately half of participants exercised at least 5 days per week for 30 min, as recommended (51.9%). Motor symptoms were a significant predictor of exercise in the count model, and self-efficacy for exercise was a significant predictor of exercise in the zero model. Severity of motor symptoms was related to frequency of exercise. Self-efficacy contributed to the probability of exercise. Symptom management and improvement of self-efficacy for exercise are important to encourage regular exercise in patients with Parkinson's disease. Copyright © 2015 Elsevier Inc. All rights reserved.

  1. Multiverse understanding of cosmological coincidences

    International Nuclear Information System (INIS)

    Bousso, Raphael; Hall, Lawrence J.; Nomura, Yasunori

    2009-01-01

    There is a deep cosmological mystery: although dependent on very different underlying physics, the time scales of structure formation, of galaxy cooling (both radiatively and against the CMB), and of vacuum domination do not differ by many orders of magnitude, but are all comparable to the present age of the universe. By scanning four landscape parameters simultaneously, we show that this quadruple coincidence is resolved. We assume only that the statistical distribution of parameter values in the multiverse grows towards certain catastrophic boundaries we identify, across which there are drastic regime changes. We find order-of-magnitude predictions for the cosmological constant, the primordial density contrast, the temperature at matter-radiation equality, the typical galaxy mass, and the age of the universe, in terms of the fine structure constant and the electron, proton and Planck masses. Our approach permits a systematic evaluation of measure proposals; with the causal patch measure, we find no runaway of the primordial density contrast and the cosmological constant to large values.

  2. Performance of a coincidence based blood activity monitor

    International Nuclear Information System (INIS)

    Moses, W.W.

    1989-12-01

    A new device has been constructed that measures the positron emitting radio-tracer concentration in arterial blood by extracting blood with a peristaltic pump, then measuring the activity concentration by detecting coincident pairs of 511 keV photons with a pair of heavy inorganic scintillators attached to photomultiplier tubes. The sensitivity of this device is experimentally determined to be 610 counts/second per μCi/ml, and has a paralyzing dead time of 1.2 μs, so is capable of measuring blood activity concentration as high as 1 mCi/ml. Its performance is compared to two other blood monitoring methods: discrete blood samples counted with a well counter and device that uses a plastic scintillator to directly detect positrons. The positron detection efficiency of this device for 18 F is greater than the plastic scintillation counter, and also eliminates the radioisotope dependent correction factors necessary to convert count rate to absolute concentration. Coincident photon detection also has the potential of reducing the background compared to direct positron detection, thereby increasing the minimum detectable isotope concentration. 10 refs., 6 figs

  3. Performance of an active well coincidence counter for HEU samples

    International Nuclear Information System (INIS)

    Ferrari, Francesca; Peerani, Paolo

    2010-01-01

    Neutron coincidence counting is the reference NDA technique used in nuclear safeguards to measure the mass of nuclear material in samples. For high-enriched uranium (HEU) samples active neutron interrogation is generally performed and the most common device used by nuclear inspectors is the Active Well Coincidence Counter (AWCC). Within her master thesis at the Polytechnic of Milan, the first author performed an intensive study on the characteristics and performances of the AWCC in order to assess the 235 U mass in HEU oxide samples at the PERLA laboratory of JRC. The work has been summarised in this paper that starts with the optimisation of the use of AWCC for nuclear safeguards, describing the calibration procedure, reporting results of a series of verification measurements, summarising the performances that can be obtained with this instruments during inspections at fuel production plants and concluding with the discussion of uncertainties related to these measurements.

  4. Computerized radioautographic grain counting

    International Nuclear Information System (INIS)

    McKanna, J.A.; Casagrande, V.A.

    1985-01-01

    In recent years, radiolabeling techniques have become fundamental assays in physiology and biochemistry experiments. They also have assumed increasingly important roles in morphologic studies. Characteristically, radioautographic analysis of structure has been qualitative rather than quantitative, however, microcomputers have opened the door to several methods for quantifying grain counts and density. The overall goal of this chapter is to describe grain counting using the Bioquant, an image analysis package based originally on the Apple II+, and now available for several popular microcomputers. The authors discuss their image analysis procedures by applying them to a study of development in the central nervous system

  5. Rainflow counting revisited

    Energy Technology Data Exchange (ETDEWEB)

    Soeker, H [Deutsches Windenergie-Institut (Germany)

    1996-09-01

    As state of the art method the rainflow counting technique is presently applied everywhere in fatigue analysis. However, the author feels that the potential of the technique is not fully recognized in wind energy industries as it is used, most of the times, as a mere data reduction technique disregarding some of the inherent information of the rainflow counting results. The ideas described in the following aim at exploitation of this information and making it available for use in the design and verification process. (au)

  6. Standardization of 18F by coincidence and LSC methods

    International Nuclear Information System (INIS)

    Roteta, Miguel; Garcia-Torano, Eduardo; Rodriguez Barquero, Leonor

    2006-01-01

    The nuclide 18 F disintegrates to 18 O by β + emission (96.86%) and electron capture (3.14%) with a half-life of 1.8288 h. It is widely used in nuclear medicine for positron emission tomography (PET). A radioactive solution of this nuclide has been standardized by two techniques: coincidence measurements with a pressurized proportional counter and liquid scintillation counting using the CIEMAT/NIST method. One ampoule containing a solution calibrated in activity was sent for measurement at the International Reference System maintained by the BIPM. Results are in excellent agreement with SIR values

  7. On the structure of the set of coincidence points

    Energy Technology Data Exchange (ETDEWEB)

    Arutyunov, A V [Peoples Friendship University of Russia, Moscow (Russian Federation); Gel' man, B D [Voronezh State University (Russian Federation)

    2015-03-31

    We consider the set of coincidence points for two maps between metric spaces. Cardinality, metric and topological properties of the coincidence set are studied. We obtain conditions which guarantee that this set (a) consists of at least two points; (b) consists of at least n points; (c) contains a countable subset; (d) is uncountable. The results are applied to study the structure of the double point set and the fixed point set for multivalued contractions. Bibliography: 12 titles.

  8. Photoion spectroscopy of atoms using coincidence techniques

    International Nuclear Information System (INIS)

    Hayaishi, Tatsuji

    1990-01-01

    Interaction of atoms or molecules with photons causes many effects which are often obscured because of many decay paths from the event. To pick up an effect in the mixed-up ones, it is necessary to observe the decay path arising the effect alone. There is a coincidence technique in one of experimental means for the purpose of observing the decay path. In this article, two coincidence measurements are presented; a photoelectron-photoion coincidence technique and a threshold photoelectron-photoion coincidence technique. Furthermore, experimental facts of rare gases atoms obtained by the techniques are reviewed. (author)

  9. A high-efficiency neutron coincidence counter for small samples

    International Nuclear Information System (INIS)

    Miller, M.C.; Menlove, H.O.; Russo, P.A.

    1991-01-01

    The inventory sample coincidence counter (INVS) has been modified to enhance its performance. The new design is suitable for use with a glove box sample-well (in-line application) as well as for use in the standard at-line mode. The counter has been redesigned to count more efficiently and be less sensitive to variations in sample position. These factors lead to a higher degree of precision and accuracy in a given counting period and allow for the practical use of the INVS counter with gamma-ray isotopics to obtain a plutonium assay independent of operator declarations and time-consuming chemicals analysis. A calculation study was performed using the Los Alamos transport code MCNP to optimize the design parameters. 5 refs., 7 figs., 8 tabs

  10. Importance of interpolation and coincidence errors in data fusion

    Science.gov (United States)

    Ceccherini, Simone; Carli, Bruno; Tirelli, Cecilia; Zoppetti, Nicola; Del Bianco, Samuele; Cortesi, Ugo; Kujanpää, Jukka; Dragani, Rossana

    2018-02-01

    The complete data fusion (CDF) method is applied to ozone profiles obtained from simulated measurements in the ultraviolet and in the thermal infrared in the framework of the Sentinel 4 mission of the Copernicus programme. We observe that the quality of the fused products is degraded when the fusing profiles are either retrieved on different vertical grids or referred to different true profiles. To address this shortcoming, a generalization of the complete data fusion method, which takes into account interpolation and coincidence errors, is presented. This upgrade overcomes the encountered problems and provides products of good quality when the fusing profiles are both retrieved on different vertical grids and referred to different true profiles. The impact of the interpolation and coincidence errors on number of degrees of freedom and errors of the fused profile is also analysed. The approach developed here to account for the interpolation and coincidence errors can also be followed to include other error components, such as forward model errors.

  11. Categorical counting.

    Science.gov (United States)

    Fetterman, J Gregor; Killeen, P Richard

    2010-09-01

    Pigeons pecked on three keys, responses to one of which could be reinforced after a few pecks, to a second key after a somewhat larger number of pecks, and to a third key after the maximum pecking requirement. The values of the pecking requirements and the proportion of trials ending with reinforcement were varied. Transits among the keys were an orderly function of peck number, and showed approximately proportional changes with changes in the pecking requirements, consistent with Weber's law. Standard deviations of the switch points between successive keys increased more slowly within a condition than across conditions. Changes in reinforcement probability produced changes in the location of the psychometric functions that were consistent with models of timing. Analyses of the number of pecks emitted and the duration of the pecking sequences demonstrated that peck number was the primary determinant of choice, but that passage of time also played some role. We capture the basic results with a standard model of counting, which we qualify to account for the secondary experiments. Copyright 2010 Elsevier B.V. All rights reserved.

  12. Sensitivity to coincidences and paranormal belief.

    Science.gov (United States)

    Hadlaczky, Gergö; Westerlund, Joakim

    2011-12-01

    Often it is difficult to find a natural explanation as to why a surprising coincidence occurs. In attempting to find one, people may be inclined to accept paranormal explanations. The objective of this study was to investigate whether people with a lower threshold for being surprised by coincidences have a greater propensity to become believers compared to those with a higher threshold. Participants were exposed to artificial coincidences, which were formally defined as less or more probable, and were asked to provide remarkability ratings. Paranormal belief was measured by the Australian Sheep-Goat Scale. An analysis of the remarkability ratings revealed a significant interaction effect between Sheep-Goat score and type of coincidence, suggesting that people with lower thresholds of surprise, when experiencing coincidences, harbor higher paranormal belief than those with a higher threshold. The theoretical aspects of these findings were discussed.

  13. Counting carbon

    DEFF Research Database (Denmark)

    Damsø, Tue; Kjær, Tyge; Christensen, Thomas Budde

    2016-01-01

    The article contains an analysis of GHG accounting methodologies applied by local governments in Denmark. Eight Danish methodologies have been identified, a Danish best practice distinguished and assessed based on the criteria for good practice in GHG accounting: Relevance, comparability, transpa...

  14. [Corrected count].

    Science.gov (United States)

    1991-11-27

    The data of the 1991 census indicated that the population count of Brazil fell short of a former estimate by 3 million people. The population reached 150 million people with an annual increase of 2%, while projections in the previous decade expected an increase of 2.48% to 153 million people. This reduction indicates more widespread use of family planning (FP) and control of fertility among families of lower social status as more information is being provided to them. However, the Ministry of Health ordered an investigation of foreign family planning organizations because it was suspected that women were forced to undergo tubal ligation during vaccination campaigns. A strange alliance of left wing politicians and the Roman Catholic Church alleges a conspiracy of international FP organizations receiving foreign funds. The FP strategies of Bemfam and Pro-Pater offer women who have little alternative the opportunity to undergo tubal ligation or to receive oral contraceptives to control fertility. The ongoing government program of distributing booklets on FP is feeble and is not backed up by an education campaign. Charges of foreign interference are leveled while the government hypocritically ignores the grave problem of 4 million abortions a year. The population is expected to continue to grow until the year 2040 and then to stabilize at a low growth rate of .4%. In 1980, the number of children per woman was 4.4 whereas the 1991 census figures indicate this has dropped to 3.5. The excess population is associated with poverty and a forsaken caste in the interior. The population actually has decreased in the interior and in cities with 15,000 people. The phenomenon of the drop of fertility associated with rural exodus is contrasted with cities and villages where the population is 20% less than expected.

  15. True coincidence-summing corrections for the coincident γ-rays measured with coplanar grid CdZnTe detectors

    International Nuclear Information System (INIS)

    Yuecel, H.; Solmaz, A.N.; Koese, E.; Bor, D.

    2010-01-01

    In this study, true coincidence-summing (TCS) correction factors have been measured for the sources 22 Na, 60 Co, 133 Ba and 152 Eu by use of three large volume coplanar grid CdZnTe (acronym: CZT) detectors. In case of a close-in detection geometry, two different TCS calculation algorithms were used to compute the required TCS correction factors. Both of the algorithms are based on the measured total-to-peak (TTP) ratio and full-energy peak (FEP) efficiency values that were obtained using almost 'single' energy and coincidence-free nuclides. The results for TCS correction factors obtained by two different algorithms were agreeable to each other. The obtained TCS factors were ranged from about 7% to 30.5% in a 2250 mm 3 CZT detector when a close counting geometry was used. For other two detectors with a volume of 1000 and 1687.5 mm 3 , the resulted TCS correction factors were relatively smaller and varied between about 0.1% and 20% at the close counting geometry condition. Therefore, the results indicate that there is a need for the estimation of TCS corrections in CZT detectors, especially when their crystal volumes are greater than 1 cm 3 and these detectors are used in the case of a close-in detection geometry.

  16. Determination of U-235 quantity in fresh fuel elements by neutron coincidence collar technique

    International Nuclear Information System (INIS)

    Almeida, M.C.M. de; Almeida, S.G. de; Marzo, M.A.S.; Moita, L.P.M.

    1990-01-01

    The U-235 quantity per lenght of fresh fuel assemblies of the Angra-I first recharge was determined by Neutron Coincidence Collar technique (N.C.C.). This technique is well-founded in fresh fuel assemblies activation by thermal neutrons from AmLi source to generate U-235 fission neutrons. These neutrons are detected by coincidence method in polyethylene structure where 18 He-3 detectors were placed. The coincidence counting results, in active mode (AmLi), showed 0,7% to standard deviation and equal to 1,49% to mass in 1000s of counting. The accuracies of different calibration methods were evaluated and compared. The results showed that the operator declared values are consistent. This evaluation was part of technical-exchange program between Safeguards Laboratory from C.N.E.N. and Los Alamos National Lab., United States. (author)

  17. Geometry-based multiplication correction for passive neutron coincidence assay of materials with variable and unknown (α,n) neutron rates

    International Nuclear Information System (INIS)

    Langner, D.G.; Russo, P.A.

    1993-02-01

    We have studied the problem of assaying impure plutonium-bearing materials using passive neutron coincidence counting. We have developed a technique to analyze neutron coincidence data from impure plutonium samples that uses the bulk geometry of the sample to correct for multiplication in samples for which the (α,n) neutron production rate is unknown. This technique can be applied to any impure plutonium-bearing material whose matrix constituents are approximately constant, whose self-multiplication is low to moderate, whose plutonium isotopic composition is known and not substantially varying, and whose bulk geometry is measurable or can be derived. This technique requires a set of reference materials that have well-characterized plutonium contents. These reference materials are measured once to derive a calibration that is specific to the neutron detector and the material. The technique has been applied to molten salt extraction residues, PuF 4 samples that have a variable salt matrix, and impure plutonium oxide samples. It is also applied to pure plutonium oxide samples for comparison. Assays accurate to 4% (1 σ) were obtained for impure samples measured in a High-Level Neutron Coincidence Counter II. The effects on the technique of variations in neutron detector efficiency with energy and the effects of neutron capture in the sample are discussed

  18. Quantitative Compton suppression spectrometry at elevated counting rates

    International Nuclear Information System (INIS)

    Westphal, G.P.; Joestl, K.; Schroeder, P.; Lauster, R.; Hausch, E.

    1999-01-01

    For quantitative Compton suppression spectrometry the decrease of coincidence efficiency with counting rate should be made negligible to avoid a virtual increase of relative peak areas of coincident isomeric transitions with counting rate. To that aim, a separate amplifier and discriminator has been used for each of the eight segments of the active shield of a new well-type Compton suppression spectrometer, together with an optimized, minimum dead-time design of the anticoincidence logic circuitry. Chance coincidence losses in the Compton suppression spectrometer are corrected instrumentally by comparing the chance coincidence rate to the counting rate of the germanium detector in a pulse-counting Busy circuit (G.P. Westphal, J. Rad. Chem. 179 (1994) 55) which is combined with the spectrometer's LFC counting loss correction system. The normally not observable chance coincidence rate is reconstructed from the rates of germanium detector and scintillation detector in an auxiliary coincidence unit, after the destruction of true coincidence by delaying one of the coincidence partners. Quantitative system response has been tested in two-source measurements with a fixed reference source of 60 Co of 14 kc/s, and various samples of 137 Cs, up to aggregate counting rates of 180 kc/s for the well-type detector, and more than 1400 kc/s for the BGO shield. In these measurements, the net peak areas of the 1173.3 keV line of 60 Co remained constant at typical values of 37 000 with and 95 000 without Compton suppression, with maximum deviations from the average of less than 1.5%

  19. Coincident effect characteristic in a thermoacoustic regenerator

    International Nuclear Information System (INIS)

    Liu Yicai; Xin Tianlong; Huang Qian; Shi Xiangnan; Chen Siming; Chen Lixin

    2011-01-01

    Many previous studies on characteristics of thermoacoustic regenerator are based on fluid micro-groups and their compression-expansion cycle. In this paper, coincident frequency is introduced to evaluate its acoustic characteristics by combining structural acoustic with structural vibration theories. The relationship among structure wave radiation and regenerator position, slab thickness, and properties of material are analyzed by numerical calculation. The results show that in the low-frequency thermoacoustic system, the coincident effect generated by higher frequency wave weakens the fundamental sound wave. While in the high-frequency thermoacoustic system, where the oscillating fundamental frequency is higher than the coincident frequency, the sound field strength is enhanced by stronger structure wave radiation because of the coincident effect.

  20. A versatile fast coincidence system with memory

    International Nuclear Information System (INIS)

    Pouthas, J.

    1976-01-01

    A versatile fast coincidence system has been studied for experiments using several detectors. In this system, all the coincidence events are produced with an associated code, and thus, different kinds of events can be processed with the same experimental set-up. Also, the classification of the logical pulses gives the possibility of using a large number of ways (30 in this system). The setting of the system is very simple: there are only two time windows to adjust. (Auth.)

  1. Simulation of triple coincidences in PET

    International Nuclear Information System (INIS)

    Cal-González, J; Herranz, E; Vicente, E; Udias, J M; Lage, E; Dave, S R; Parot, V; Herraiz, J L; Moore, S C; Park, M-A

    2015-01-01

    Although current PET scanners are designed and optimized to detect double coincidence events, there is a significant amount of triple coincidences in any PET acquisition. Triple coincidences may arise from causes such as: inter-detector scatter (IDS), random triple interactions (R T ), or the detection of prompt gamma rays in coincidence with annihilation photons when non-pure positron-emitting radionuclides are used (β + γ events). Depending on the data acquisition settings of the PET scanner, these triple events are discarded or processed as a set of double coincidences if the energy of the three detected events is within the scanner’s energy window. This latter option introduces noise in the data, as at most, only one of the possible lines-of-response defined by triple interactions corresponds to the line along which the decay occurred. Several novel works have pointed out the possibility of using triple events to increase the sensitivity of PET scanners or to expand PET imaging capabilities by allowing differentiation between radiotracers labeled with non-pure and pure positron-emitting radionuclides. In this work, we extended the Monte Carlo simulator PeneloPET to assess the proportion of triple coincidences in PET acquisitions and to evaluate their possible applications. We validated the results of the simulator against experimental data acquired with a modified version of a commercial preclinical PET/CT scanner, which was enabled to acquire and process triple-coincidence events. We used as figures of merit the energy spectra for double and triple coincidences and the triples-to-doubles ratio for different energy windows and radionuclides. After validation, the simulator was used to predict the relative quantity of triple-coincidence events in two clinical scanners assuming different acquisition settings. Good agreement between simulations and preclinical experiments was found, with differences below 10% for most of the observables considered. For

  2. Quintessence, Cosmic Coincidence, and the Cosmological Constant

    International Nuclear Information System (INIS)

    Zlatev, I.; Wang, L.; Steinhardt, P.J.; Steinhardt, P.J.

    1999-01-01

    Recent observations suggest that a large fraction of the energy density of the Universe has negative pressure. One explanation is vacuum energy density; another is quintessence in the form of a scalar field slowly evolving down a potential. In either case, a key problem is to explain why the energy density nearly coincides with the matter density today. The densities decrease at different rates as the Universe expands, so coincidence today appears to require that their ratio be set to a specific, infinitesimal value in the early Universe. In this paper, we introduce the notion of a open-quotes tracker field,close quotes a form of quintessence, and show how it may explain the coincidence, adding new motivation for the quintessence scenario. copyright 1999 The American Physical Society

  3. Slow coincidences for CAMAC multiparameter analysis

    International Nuclear Information System (INIS)

    Akimov, Yu.K.; Kalinin, A.I.; Tissol'd, E.; Fromm, V.D.; Ekstein, P.

    1978-01-01

    A coincidence circuit with controlled parameters is described. The circuit has six coincidence inputs and one input for anticoincidences. A pulse duration in channels is changed from 0.25 to 5 μs and delay time, within 8 μs. The circuit is developed for multiparameter spectrometric analysis with the use of amplitude-digital and time-digital convertors. Its introduction permits one to diminish considerably the ''dead'' time of apparatus and to select rapidly and reliably strictly correlated digital information from convertors

  4. Theoretical and Experimental Investigations of Coincidences in Poisson Distributed Pulse Trains and Spectral Distortion Caused by Pulse Pileup.

    Science.gov (United States)

    Bristow, Quentin

    1990-01-01

    Part one of this two-part study is concerned with the multiple coincidences in pulse trains from X-ray and gamma radiation detectors which are the cause of pulse pileup. A sequence of pulses with inter-arrival times less than tau, the resolving time of the pulse-height analysis system used to acquire spectra, is called a multiple pulse string. Such strings can be classified on the basis of the number of pulses they contain, or the number of resolving times they cover. The occurrence rates of such strings are derived from theoretical considerations. Logic circuits were devised to make experimental measurements of multiple pulse string occurrence rates in the output from a NaI(Tl) scintillation detector over a wide range of count rates. Markov process theory was used to predict state transition rates in the logic circuits, enabling the experimental data to be checked rigorously for conformity with those predicted for a Poisson distribution. No fundamental discrepancies were observed. Part two of the study is concerned with a theoretical analysis of pulse pileup and the development of a discrete correction algorithm, based on the use of a function to simulate the coincidence spectrum produced by partial sums of pulses. Monte Carlo simulations, incorporating criteria for pulse pileup inherent in the operation of modern ADC's, were used to generate pileup spectra due to coincidences between two pulses, (1st order pileup) and three pulses (2nd order pileup), for different semi-Gaussian pulse shapes. Coincidences between pulses in a single channel produced a basic probability density function spectrum which can be regarded as an impulse response for a particular pulse shape. The use of a flat spectrum (identical count rates in all channels) in the simulations, and in a parallel theoretical analysis, showed the 1st order pileup distorted the spectrum to a linear ramp with a pileup tail. The correction algorithm was successfully applied to correct entire spectra for 1st and

  5. Determining chance coincidence, survival factor and decay factor in 220Rn delayed coincidence measurement

    International Nuclear Information System (INIS)

    Huang Derong; Yan Yongjun; Zhou Jianliang; Qiu Shoukang

    2013-01-01

    The method and calculation formulas to determine the chance coincidence in the 220 Rn coincidence measurement are introduced in this paper. The poisson distribution is introduced to correct the chance coincidence. The relative deviation of the true coincidence between the method and the Giffin's is within 5% after the correction of the cohance coincidence. The measurement of 220 Rn is done by comparative measurement with RAD7. The results shows that 220 Rn can be measured by the method with a relative deviation of 14%. Mean while, for the 220 Rn flow regime is difficult to meet the condition of calculation formulas, a solution to solve the survival factor and decay factor is proposed and the error come from the useage of theoretical calculation formula is avoided. (authors)

  6. Tachyon driven solution to Cosmic Coincidence Problrm

    OpenAIRE

    Srivastaca, S. K.

    2004-01-01

    Here, non-minimally coupled tachyon to gravity is considered as a source of "dark energy". It is demonstrated that with expansion of the universe, tachyon dark energy decays to "dark matter" providing a solution to "cosmic coincidence problem".Moreover, it is found that universe undergoes accelerated expansion simultaneously.

  7. Using Compton scattering for random coincidence rejection

    International Nuclear Information System (INIS)

    Kolstein, M.; Chmeissani, M.

    2016-01-01

    The Voxel Imaging PET (VIP) project presents a new approach for the design of nuclear medicine imaging devices by using highly segmented pixel CdTe sensors. CdTe detectors can achieve an energy resolution of ≈ 1% FWHM at 511 keV and can be easily segmented into submillimeter sized voxels for optimal spatial resolution. These features help in rejecting a large part of the scattered events from the PET coincidence sample in order to obtain high quality images. Another contribution to the background are random events, i.e., hits caused by two independent gammas without a common origin. Given that 60% of 511 keV photons undergo Compton scattering in CdTe (i.e. 84% of all coincidence events have at least one Compton scattering gamma), we present a simulation study on the possibility to use the Compton scattering information of at least one of the coincident gammas within the detector to reject random coincidences. The idea uses the fact that if a gamma undergoes Compton scattering in the detector, it will cause two hits in the pixel detectors. The first hit corresponds to the Compton scattering process. The second hit shall correspond to the photoelectric absorption of the remaining energy of the gamma. With the energy deposition of the first hit, one can calculate the Compton scattering angle. By measuring the hit location of the coincident gamma, we can construct the geometric angle, under the assumption that both gammas come from the same origin. Using the difference between the Compton scattering angle and the geometric angle, random events can be rejected.

  8. Low level radioactivity measurements with phoswich detectors using coincident techniques and digital pulse processing analysis.

    Science.gov (United States)

    de la Fuente, R; de Celis, B; del Canto, V; Lumbreras, J M; de Celis Alonso, B; Martín-Martín, A; Gutierrez-Villanueva, J L

    2008-10-01

    A new system has been developed for the detection of low radioactivity levels of fission products and actinides using coincidence techniques. The device combines a phoswich detector for alpha/beta/gamma-ray recognition with a fast digital card for electronic pulse analysis. The phoswich can be used in a coincident mode by identifying the composed signal produced by the simultaneous detection of alpha/beta particles and X-rays/gamma particles. The technique of coincidences with phoswich detectors was proposed recently to verify the Nuclear Test Ban Treaty (NTBT) which established the necessity of monitoring low levels of gaseous fission products produced by underground nuclear explosions. With the device proposed here it is possible to identify the coincidence events and determine the energy and type of coincident particles. The sensitivity of the system has been improved by employing liquid scintillators and a high resolution low energy germanium detector. In this case it is possible to identify simultaneously by alpha/gamma coincidence transuranic nuclides present in environmental samples without necessity of performing radiochemical separation. The minimum detectable activity was estimated to be 0.01 Bq kg(-1) for 0.1 kg of soil and 1000 min counting.

  9. Low level radioactivity measurements with phoswich detectors using coincident techniques and digital pulse processing analysis

    International Nuclear Information System (INIS)

    Fuente, R. de la; Celis, B. de; Canto, V. del; Lumbreras, J.M.; Celis, Alonso B. de; Martin-Martin, A.; Gutierrez-Villanueva, J.L.

    2008-01-01

    A new system has been developed for the detection of low radioactivity levels of fission products and actinides using coincidence techniques. The device combines a phoswich detector for α/β/γ-ray recognition with a fast digital card for electronic pulse analysis. The phoswich can be used in a coincident mode by identifying the composed signal produced by the simultaneous detection of α/β particles and X-rays/γ particles. The technique of coincidences with phoswich detectors was proposed recently to verify the Nuclear Test Ban Treaty (NTBT) which established the necessity of monitoring low levels of gaseous fission products produced by underground nuclear explosions. With the device proposed here it is possible to identify the coincidence events and determine the energy and type of coincident particles. The sensitivity of the system has been improved by employing liquid scintillators and a high resolution low energy germanium detector. In this case it is possible to identify simultaneously by α/γ coincidence transuranic nuclides present in environmental samples without necessity of performing radiochemical separation. The minimum detectable activity was estimated to be 0.01 Bq kg -1 for 0.1 kg of soil and 1000 min counting

  10. Application of neutron multiplicity counting to waste assay

    Energy Technology Data Exchange (ETDEWEB)

    Pickrell, M.M.; Ensslin, N. [Los Alamos National Lab., NM (United States); Sharpe, T.J. [North Carolina State Univ., Raleigh, NC (United States)

    1997-11-01

    This paper describes the use of a new figure of merit code that calculates both bias and precision for coincidence and multiplicity counting, and determines the optimum regions for each in waste assay applications. A {open_quotes}tunable multiplicity{close_quotes} approach is developed that uses a combination of coincidence and multiplicity counting to minimize the total assay error. An example is shown where multiplicity analysis is used to solve for mass, alpha, and multiplication and tunable multiplicity is shown to work well. The approach provides a method for selecting coincidence, multiplicity, or tunable multiplicity counting to give the best assay with the lowest total error over a broad spectrum of assay conditions. 9 refs., 6 figs.

  11. Importance of interpolation and coincidence errors in data fusion

    Directory of Open Access Journals (Sweden)

    S. Ceccherini

    2018-02-01

    Full Text Available The complete data fusion (CDF method is applied to ozone profiles obtained from simulated measurements in the ultraviolet and in the thermal infrared in the framework of the Sentinel 4 mission of the Copernicus programme. We observe that the quality of the fused products is degraded when the fusing profiles are either retrieved on different vertical grids or referred to different true profiles. To address this shortcoming, a generalization of the complete data fusion method, which takes into account interpolation and coincidence errors, is presented. This upgrade overcomes the encountered problems and provides products of good quality when the fusing profiles are both retrieved on different vertical grids and referred to different true profiles. The impact of the interpolation and coincidence errors on number of degrees of freedom and errors of the fused profile is also analysed. The approach developed here to account for the interpolation and coincidence errors can also be followed to include other error components, such as forward model errors.

  12. A method for measuring the energy spectrum of coincidence events in positron emission tomography.

    Science.gov (United States)

    Goertzen, Andrew L; Stout, David B; Thompson, Christopher J

    2010-01-21

    Positron emission tomography (PET) system energy response is typically characterized in singles detection mode, yet there are situations in which the energy spectrum of coincidence events might be different than the spectrum measured in singles mode. Examples include imaging with isotopes that emit a prompt gamma in coincidence with a positron emission, imaging with low activity in a LSO/LYSO-based cameras, in which the intrinsic activity is significant, and in high scatter situations where the two 511 keV photons have different scattering probabilities (i.e. off-center line source). The ability to accurately measure the energy spectrum of coincidence events could be used for validating simulation models, optimizing energy discriminator levels and examining scatter models and corrections. For many PET systems operating in coincidence mode, the only method available for estimating the energy spectrum is to step the lower and upper level discriminators (LLD and ULD). Simple measurement techniques such as using a narrow sliding energy window or stepping only the LLD will not yield a spectrum of coincidence events that is accurate for cases where there are different energy components contributing to the spectrum. In this work we propose a new method of measuring the energy spectrum of coincidence events in PET based on a linear combination of two sets of coincident count measurements: one made by stepping the LLD and one made by stepping the ULD. The method was tested using both Monte Carlo simulations of a Siemens microPET R4 camera and measured data acquired on a Siemens Inveon PET camera. The results show that our energy spectrum calculation method accurately measures the coincident energy spectra for cases including the beta/gamma spectrum of the (176)Lu intrinsic activity present in the LSO scintillator crystals, a (68)Ge source and an (124)I source (in which there are prompt gamma-rays emitted together with the positron).

  13. Development of coincidence processing module for PEM

    International Nuclear Information System (INIS)

    Feng Baotong; Shuai Lei; Li Ke

    2011-01-01

    For the breast cancer diagnosis and therapy, a prototype of positron emission mammography (PEM) was developed in Institute of High Energy Physics, Chinese Academy of Sciences. In this paper, the design of coincidence processing module (CPM) for this PEM was presented. Both the hardware architecture and the software logic were introduced. In this design, the CPM used the Rocket IO fast interface in FPGA and fiber technology to acquire the preprocessed data from the continuous sampling module (CSM) and then selected the valid event with the coincidence timing window method, which was performed in the FPGA on the daughter board. The CPM transmits the processed data to host computer via gigabit Ethernet. The whole system was controlled by CAN bus. The primary tests indicate that the performance of this design is good. (authors)

  14. Effect of time walk in the use of single channel analyzer/discriminator for saturated pulses in the 4πβ–γ coincidence experiments

    International Nuclear Information System (INIS)

    Kawada, Yasushi; Yunoki, Akira; Yamada, Takahiro; Hino, Yoshio

    2016-01-01

    Using the TAC technique, the timing properties of a 4πβ–γ coincidence counting system were experimentally studied with an emphasis on saturated pulses. Experiments were performed for several discriminators (integral mode of TSCA) each with different kinds of timing techniques. Timing spectra were measured at various applied voltage to the 4π proportional detector covering the entire region of the plateau. Most of timing discriminators show good timing property when the pulses remain the linear region, but suddenly deteriorate after the pulses was saturated, and the timing spectra expands seriously up to a few μs in some types of timing discriminator. To overcome this problem, two techniques were proposed. - Highlights: • Timing properties of several kinds of SCA/Discriminators were studied, including trailing edge CFT. • Focus of study on saturated pulses, using a 4πβ–γ coincidence counting system and TAC. • Validity of two novel techniques to overcome this problem was shown.

  15. New way on designing majorant coincidence circuits

    International Nuclear Information System (INIS)

    Gajdamaka, R.I.; Kalinnikov, V.A.; Nikityuk, N.M.; Shirikov, V.P.

    1982-01-01

    A new way of designing fast devices of combinatorial selection by the number of particles passing through a multichannel charged particle detector is decribed. The algorithm of their operation is based on modern algebraic coding theory. By application of analytical computational methods Boolean expressions can be obtianed for designing basic circuits for a large number of inputs. An example of computation of 15 inputs majorant coincidence circuit is considered

  16. Kinematical coincidence method in transfer reactions

    Energy Technology Data Exchange (ETDEWEB)

    Acosta, L.; Amorini, F. [INFN—Laboratori Nazionali del Sud, Via S. Sofia, Catania (Italy); Auditore, L. [INFN Gruppo Collegato di Messina and Dipartimento di Fisica, Università di Messina (Italy); Berceanu, I. [Institute for Physics and Nuclear Engineering, Bucharest (Romania); Cardella, G., E-mail: cardella@ct.infn.it [INFN—Sezione di Catania, Via S. Sofia, 95123 Catania (Italy); Chatterjiee, M.B. [Saha Institute for Nuclear Physics, Kolkata (India); De Filippo, E. [INFN—Sezione di Catania, Via S. Sofia, 95123 Catania (Italy); Francalanza, L.; Gianì, R. [INFN—Laboratori Nazionali del Sud, Via S. Sofia, Catania (Italy); Dipartimento di Fisica e Astronomia, Università di Catania, Via S. Sofia, Catania (Italy); Grassi, L. [INFN—Sezione di Catania, Via S. Sofia, 95123 Catania (Italy); Rudjer Boskovic Institute, Zagreb (Croatia); Grzeszczuk, A. [Institut of Physics, University of Silesia, Katowice (Poland); La Guidara, E. [INFN—Sezione di Catania, Via S. Sofia, 95123 Catania (Italy); Centro Siciliano di Fisica Nucleare e Struttura della Materia, Catania (Italy); Lanzalone, G. [INFN—Laboratori Nazionali del Sud, Via S. Sofia, Catania (Italy); Facoltà di Ingegneria e Architettura, Università Kore, Enna (Italy); Lombardo, I. [INFN—Laboratori Nazionali del Sud, Via S. Sofia, Catania (Italy); Dipartimento di Scienze Fisiche, Università Federico II and INFN Sezione di Napoli (Italy); Loria, D.; Minniti, T. [INFN Gruppo Collegato di Messina and Dipartimento di Fisica, Università di Messina (Italy); Pagano, E.V. [INFN—Laboratori Nazionali del Sud, Via S. Sofia, Catania (Italy); Dipartimento di Fisica e Astronomia, Università di Catania, Via S. Sofia, Catania (Italy); and others

    2013-07-01

    A new method to extract high resolution angular distributions from kinematical coincidence measurements in binary reactions is presented. Kinematics is used to extract the center of mass angular distribution from the measured energy spectrum of light particles. Results obtained in the case of {sup 10}Be+p→{sup 9}Be+d reaction measured with the CHIMERA detector are shown. An angular resolution of few degrees in the center of mass is obtained. The range of applicability of the method is discussed.

  17. Coincident-inclusive electrofission angular correlations

    International Nuclear Information System (INIS)

    Arruda Neto, J.D.T.

    1983-08-01

    A method for the joint analysis of coincident and inclusive electrofission data, in order to minimize effects of the model dependence of data interpretation, is developed. Explicit calculations of the (e,e'f) angular correlations are presented. The potentialities of the method to the study of sub- and near-barrier properties of the fission process, and to the study of the giant resonances fission mode, are discussed. (Author) [pt

  18. Timing coincidence studies with fast photomultipliers

    International Nuclear Information System (INIS)

    Raoof, M.A.; Raoof, S.A.

    1981-01-01

    The time response of RCA C70045D photomultipliers was studied using a subnanosecond light flasher. The tubes, which have an output rise time of approximately 0.5 ns, were used in coincidence to study the variations in the fwhm of the time spectrum over a certain dynamic range of pulse amplitudes for both leading edge and constant fraction discrimination. A comparison has also been made for the measured time resolutions with some of the other fast photomultipliers. (orig.)

  19. Instrumentation and data handling. I. Positron coincidence imaging with the TOKIM system

    International Nuclear Information System (INIS)

    Anon.

    1976-01-01

    In addition to the conventional singles mode of operation, the TOKIM system's two Anger-type gamma cameras may be used in the (stationary, 180 0 opposition) coincidence mode, making it possible to achieve tomographic imaging with three-dimensional spatial resolution and high detection sensitivity, utilizing β + emitting radioisotopes. This method, however, suffers from certain inherent limitations. Our efforts during this past year to improve upon the TOKIM imaging capability in the β + mode have been directed towards the reduction of the limitations by the following means: the removal of out of focal plane image contributions through a computerized iterative correction procedure, coupled with coincidence aperture limitation to achieve uniform sensitivity across a reasonable portion of the detector pair diameter, and the application of Muehllehner's graded filter approach to the TOKIM to increase the ratio of usable coincidence events versus singles count rate

  20. System for ν-ν-coincidence spectra processing with data compression

    International Nuclear Information System (INIS)

    Byalko, A.A.; Volkov, N.G.; Tsupko-Sitnikov, V.M.; Churakov, A.K.

    1982-01-01

    Calculational algorithm and program for analyzing gamma-gamma coincidence spectra based on using the method of expansion in singular values for data compression (the SVD method) are described. Results of the testing of the program during the processing of coincidence spectrum for the low-energy region of transitions corresponding to decay 164 Lu → 164 Yb are given. The program is written in the FORTRAN language and is realized by the ES-1040 computer. The counting time constitutes about 20 min. It is concluded that the use of the SVD method permits to correct the data at the expense of distortion filtration caused with statistical deviations and random interferences, at that not distorting the initial data. The data compressed correspond more to theoretical suggestions of forms of semiconductor detector lines and two-dimensional line in the coincidence spectrum

  1. Simulations of Lithium-Based Neutron Coincidence Counter for Gd-Loaded Fuel

    Energy Technology Data Exchange (ETDEWEB)

    Cowles, Christian C. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Kouzes, Richard T. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Siciliano, Edward R. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2014-10-01

    The Department of Energy Office of Nuclear Safeguards and Security (NA-241) is supporting the project Lithium-Based Alternative Neutron Detection Technology Coincidence Counting for Gd-loaded Fuels at Pacific Northwest National Laboratory for the development of a lithium-based neutron coincidence counter for nondestructively assaying Gd loaded nuclear fuel. This report provides results from MCNP simulations of a lithium-based coincidence counter for the possible measurement of Gd-loaded nuclear fuel. A comparison of lithium-based simulations and UNCL-II simulations with and without Gd loaded fuel is provided. A lithium-based model, referred to as PLNS3A-R1, showed strong promise for assaying Gd loaded fuel.

  2. Studies of weak capture-gamma-ray resonances via coincidence techniques

    CERN Document Server

    Rowland, C; Champagne, A E; Dummer, A K; Fitzgerald, R; Harley, E C T; Mosher, J; Runkle, R

    2002-01-01

    A method for measuring weak capture-gamma-ray resonances via gamma gamma-coincidence counting techniques is described. The coincidence apparatus consisted of a large-volume germanium detector and an annular NaI(Tl) crystal. The setup was tested by measuring the weak E sub R =227 keV resonance in sup 2 sup 6 Mg(p,gamma) sup 2 sup 7 Al. Absolute germanium and NaI(Tl) counting efficiencies for a range of gamma-ray energies and for different detector-target geometries are presented. Studies of the gamma-ray background in our spectra are described. Compared to previous work, our method improves the detection sensitivity for weak capture-gamma-ray resonances by a factor of approx 100. The usefulness of the present technique for investigations of interest to nuclear astrophysics is discussed.

  3. Electron emission relevant to inner-shell photoionization of condensed water studied by multi-electron coincidence spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Hikosaka, Y., E-mail: hikosaka@las.u-toyama.ac.jp [Graduate School of Medicine and Pharmaceutical Sciences, University of Toyama, Toyama 930-0194 (Japan); Mashiko, R.; Konosu, Y.; Soejima, K. [Department of Environmental Science, Niigata University, Niigata 950-2181 (Japan); Shigemasa, E. [UVSOR Facility, Institute for Molecular Science, Okazaki 444-8585 (Japan); SOKENDAI, Okazaki 444-8585 (Japan)

    2016-11-15

    Highlights: • Multi-electron coincidence spectroscopy is applied to the study of electron emissions from condensed H2O molecules. • Coincidence Auger spectra are obtained for different photoelectron energies. • The energy distribution of the slow electrons ejected in the Auger decay is deduced from three-fold coincidences. - Abstract: Multi-electron coincidence spectroscopy using a magnetic-bottle electron spectrometer has been applied to the study of the Auger decay following O1s photoionization of condensed H{sub 2}O molecules. Coincidence Auger spectra are obtained for three different photoelectron energy ranges. In addition, the energy distribution of the slow electrons ejected in the Auger decay of the O1s core hole is deduced from three-fold coincidences.

  4. Evaluation of B10Plus+* proportional detectors for neutron coincidence counting

    Energy Technology Data Exchange (ETDEWEB)

    Beddingfield, David H.; Yoon, Seokryung [International Atomic Energy Agency, Vienna International Centre, PO Box 100, 1400 Vienna, (Austria)

    2015-07-01

    GE-Reuter-Stokes (GERS) has developed a new line of neutron proportional counters, the B10Plus+* proportional counter. The detector design is intended to serve as a cost-effective alternative to traditional {sup 3}He proportional counters in a variety of applications. The detector is a hybrid design 10B-lined tube optimized with the addition of a small quantity of 3He gas to improve the detector performance and efficiency. As a demonstration of the B10Plus+* detector, GERS has constructed a Uranium Neutron Collar (UNCL) system consisting of B-10Plus+* proportional counters. GERS has designed and built a demonstration UNCL system intended to match the performance of a Type-I UNCL design in Pressurized Water Reactor (PWR) geometry operating in thermal mode. GERS offered their system on loan to the International Atomic Energy Agency (IAEA) Safeguards Division of Technical and Scientific Services for an assessment of the detector technology and the demonstration system. We have characterized the demonstration UNCL system and compared its performance with a traditional Type-I UNCL design in regular use by the IAEA. This paper summarizes our findings and observations during the characterization and testing activity. (authors)

  5. Clean Hands Count

    Medline Plus

    Full Text Available ... Like this video? Sign in to make your opinion count. Sign in 131 2 Don't like this video? Sign in to make your opinion count. Sign in 3 Loading... Loading... Transcript The ...

  6. The Big Pumpkin Count.

    Science.gov (United States)

    Coplestone-Loomis, Lenny

    1981-01-01

    Pumpkin seeds are counted after students convert pumpkins to jack-o-lanterns. Among the activities involved, pupils learn to count by 10s, make estimates, and to construct a visual representation of 1,000. (MP)

  7. Recovering the triple coincidence of non-pure positron emitters in preclinical PET

    Science.gov (United States)

    Lin, Hsin-Hon; Chuang, Keh-Shih; Chen, Szu-Yu; Jan, Meei-Ling

    2016-03-01

    Non-pure positron emitters, with their long half-lives, allow for the tracing of slow biochemical processes which cannot be adequately examined by the commonly used short-lived positron emitters. Most of these isotopes emit high-energy cascade gamma rays in addition to positron decay that can be detected and create a triple coincidence with annihilation photons. Triple coincidence is discarded in most scanners, however, the majority of the triple coincidence contains true photon pairs that can be recovered. In this study, we propose a strategy for recovering triple coincidence events to raise the sensitivity of PET imaging for non-pure positron emitters. To identify the true line of response (LOR) from a triple coincidence, a framework utilizing geometrical, energy and temporal information is proposed. The geometrical criterion is based on the assumption that the LOR with the largest radial offset among the three sub pairs of triple coincidences is least likely to be a true LOR. Then, a confidence time window is used to test the valid LOR among those within triple coincidence. Finally, a likelihood ratio discriminant rule based on the energy probability density distribution of cascade and annihilation gammas is established to identify the true LOR. An Inveon preclinical PET scanner was modeled with GATE (GEANT4 application for tomographic emission) Monte Carlo software. We evaluated the performance of the proposed method in terms of identification fraction, noise equivalent count rates (NECR), and image quality on various phantoms. With the inclusion of triple coincidence events using the proposed method, the NECR was found to increase from 11% to 26% and 19% to 29% for I-124 and Br-76, respectively, when 7.4-185 MBq of activity was used. Compared to the reconstructed images using double coincidence, this technique increased the SNR by 5.1-7.3% for I-124 and 9.3-10.3% for Br-76 within the activity range of 9.25-74 MBq, without compromising the spatial resolution or

  8. A coincidence study between photo- and Auger electrons

    International Nuclear Information System (INIS)

    Ricz, S.; Koever, A.; Varga, D.; Molnar, J.; Aksela, S.; Jurvansuu, M.

    2000-01-01

    Complete text of publication follows. The investigation of double differential cross sections of photon induced Auger electrons provides very sensitive method for studying the rearrangement process, especially when the angular correlation between photo- and Auger electrons is also studied. Such type of measurements could reveal a new aspect in studying the electron-electron, hole-electron and photoelectron - Auger electron interactions. It enables one to separate the overlapping Auger lines belonging to different initial holes. The traditional coincidence measurement is very time consuming and causes serious calibration problems. In order to overcome these experimental difficulties a new electron-spectrometer (ESA-22) was developed in ATOMKI, Debrecen in cooperation with the Electron spectroscopy group of University of Oulu, Finland. The analyzer consists of a spherical and a cylindrical part. It is very similar to the ESA-21 analyzer. The main differences is that the focal ring can be set different diameters thus either a series of channel detectors can be used to detect the electrons at different angles or a position sensitive channel plate can be applied for simultaneous angular recording of electrons. Furthermore the outer sphere and cylinder are cut into two parts so the spectrometer is capable to analyze two independent angularly resolved electron spectra (in the 0 deg - 180 deg region) at different energy regions, simultaneously. A special electronic control and data handling electronics and software was worked out to control the analyzer. The first results were presented in. In the last year the ESA-22 electron-spectrometer was transported to the I411 beam line of MAX-II synchrotron in Lund, Sweden. The advanced properties of the spectrometer was investigated by measuring coincidences between the photoelectrons originated from the Ar L 3 subshell and the Ar Auger electrons in the 203-207 eV energy region. Fig. 1 shows the single and the coincidence spectra

  9. Unattended mode monitoring of passive neutron coincidence detector systems using a commercial data logger

    International Nuclear Information System (INIS)

    Smith, B.G.R.; Outram, J.D.; Storey, M.

    1991-01-01

    A commercial Data Logger for unattended passive neutron coincidence data acquisition is described. This consists of an inexpensive commercial Data Logging equipment attached to a neutron coincidence electronics and a software package for data review. The Data Logger permits both the flexible configuration of a passive neutron coincidence measurement system for unattended mode monitoring and the storage of the measured Totals and Reals count rates. An additional feature of the Data Logger is a custom software package providing for the complete analysis of the stored data and yielding an assay of each item passing through the measurement cavity. The analysis includes an input for different isotopic compositions, the calculation of the multiplication corrected Reals rates, the inclusion of a calibration functions, and the determination of 240 Pu masses. The software package for data review displays the Totals and Reals count rates logged by the Data Logger as a function of time. In addition the custom software provides input files to the data review package to display the multiplication corrected Reals count rates and the measured 240 Pu masses as a function of time. Information on the Data Logger is presented along with the monitoring mode specifications. The analysis functions implemented are described as is the data review software. Results are presented for a specific application

  10. Coincidence logic modules for criticality alarming

    International Nuclear Information System (INIS)

    Schaief, C.C. III.

    1977-04-01

    A coincidence Logic Module and a companion contact closure Relay Module utilizing the NIM Standard have been developed for criticality alarming. The units provide an ALARM whenever two or more out of N detectors become activated. In addition, an ALERT is generated whenever one or more detectors is activated or when certain electronic component failures occur. The number of detector inputs (N) can be expanded in groups of six by adding modules. Serial and parallel redundancy were used to reduce the probability of system failure

  11. Radiation counting statistics

    Energy Technology Data Exchange (ETDEWEB)

    Suh, M. Y.; Jee, K. Y.; Park, K. K.; Park, Y. J.; Kim, W. H

    1999-08-01

    This report is intended to describe the statistical methods necessary to design and conduct radiation counting experiments and evaluate the data from the experiment. The methods are described for the evaluation of the stability of a counting system and the estimation of the precision of counting data by application of probability distribution models. The methods for the determination of the uncertainty of the results calculated from the number of counts, as well as various statistical methods for the reduction of counting error are also described. (Author). 11 refs., 8 tabs., 8 figs.

  12. Radiation counting statistics

    Energy Technology Data Exchange (ETDEWEB)

    Suh, M. Y.; Jee, K. Y.; Park, K. K. [Korea Atomic Energy Research Institute, Taejon (Korea)

    1999-08-01

    This report is intended to describe the statistical methods necessary to design and conduct radiation counting experiments and evaluate the data from the experiments. The methods are described for the evaluation of the stability of a counting system and the estimation of the precision of counting data by application of probability distribution models. The methods for the determination of the uncertainty of the results calculated from the number of counts, as well as various statistical methods for the reduction of counting error are also described. 11 refs., 6 figs., 8 tabs. (Author)

  13. Radiation counting statistics

    International Nuclear Information System (INIS)

    Suh, M. Y.; Jee, K. Y.; Park, K. K.; Park, Y. J.; Kim, W. H.

    1999-08-01

    This report is intended to describe the statistical methods necessary to design and conduct radiation counting experiments and evaluate the data from the experiment. The methods are described for the evaluation of the stability of a counting system and the estimation of the precision of counting data by application of probability distribution models. The methods for the determination of the uncertainty of the results calculated from the number of counts, as well as various statistical methods for the reduction of counting error are also described. (Author). 11 refs., 8 tabs., 8 figs

  14. Evaluation of accidental coincidences for time-differential Moessbauer-spectroscopy

    International Nuclear Information System (INIS)

    Alflen, M.; Meyer, W.

    1995-01-01

    The accidental coincidences of a measuring system based on time-to-amplitude conversion are considered in some detail for the case of low starting and high stopping rates. Two types of accidental coincidences are distinguished, those carrying time information and those without time information. Neglecting any deadtime effects of the detectors, analytical expressions for the calculation of the time distribution of the random coincidences are evaluated. The analytical expressions have been confirmed by Monte Carlo simulations. The procedure is applied to time-differential Moessbauer spectroscopy in order to extract the time spectra of true coincidences. The measured spectrum in a time channel turns out to be a superposition of the true spectrum (true coincidences), a time integral spectrum (random coincidences), and a weighted superposition of true spectra of other time channels (random but time carrying information). A measurement with a single line 57 Co/Rh-source and single line K[Fe(CN) 6 ].3H 2 O-absorber with stopping rates of 1 MBq shows agreement between the theoretical time-filtered spectra and the corrected measured spectra of true coincidences. ((orig.))

  15. Heterogeneous counting on filter support media

    International Nuclear Information System (INIS)

    Long, E.; Kohler, V.; Kelly, M.J.

    1976-01-01

    Many investigators in the biomedical research area have used filter paper as the support for radioactive samples. This means that a heterogeneous counting of sample sometimes results. The count rate of a sample on a filter will be affected by positioning, degree of dryness, sample application procedure, the type of filter, and the type of cocktail used. Positioning of the filter (up or down) in the counting vial can cause a variation of 35% or more when counting tritiated samples on filter paper. Samples of varying degrees of dryness when added to the counting cocktail can cause nonreproducible counts if handled improperly. Count rates starting at 2400 CPM initially can become 10,000 CPM in 24 hours for 3 H-DNA (deoxyribonucleic acid) samples dried on standard cellulose acetate membrane filters. Data on cellulose nitrate filters show a similar trend. Sample application procedures in which the sample is applied to the filter in a small spot or on a large amount of the surface area can cause nonreproducible or very low counting rates. A tritiated DNA sample, when applied topically, gives a count rate of 4,000 CPM. When the sample is spread over the whole filter, 13,400 CPM are obtained with a much better coefficient of variation (5% versus 20%). Adding protein carrier (bovine serum albumin-BSA) to the sample to trap more of the tritiated DNA on the filter during the filtration process causes a serious beta absorption problem. Count rates which are one-fourth the count rate applied to the filter are obtained on calibrated runs. Many of the problems encountered can be alleviated by a proper choice of filter and the use of a liquid scintillation cocktail which dissolves the filter. Filter-Solv has been used to dissolve cellulose nitrate filters and filters which are a combination of cellulose nitrate and cellulose acetate. Count rates obtained for these dissolved samples are very reproducible and highly efficient

  16. Optimized coincidence Doppler broadening spectroscopy using deconvolution algorithms

    International Nuclear Information System (INIS)

    Ho, K.F.; Ching, H.M.; Cheng, K.W.; Beling, C.D.; Fung, S.; Ng, K.P.

    2004-01-01

    In the last few years a number of excellent deconvolution algorithms have been developed for use in ''de-blurring'' 2D images. Here we report briefly on one such algorithm we have studied which uses the non-negativity constraint to optimize the regularization and which is applied to the 2D image like data produced in Coincidence Doppler Broadening Spectroscopy (CDBS). The system instrumental resolution functions are obtained using the 514 keV line from 85 Sr. The technique when applied to a series of well annealed polycrystalline metals gives two photon momentum data on a quality comparable to that obtainable using 1D Angular Correlation of Annihilation Radiation (ACAR). (orig.)

  17. A coincidence-type ion-electron converter detector for low-energy protons

    International Nuclear Information System (INIS)

    Benka, O.; Weinzierl, P.; Dobrozemsky, R.; Stratowa, C.

    1981-04-01

    A coincidence type ion-electron converter detector has been developed and used - together with an electrostatic energy-analyser - for precision measurements of the energy distribution of recoil protons from free-neutron decay. The most important aspect of the development was, besides keeping the background below 0,2 counts/sec in the presence of a certain radiation background, to achieve a high and energy-independent counting probability for protons with energies between 100 and 1000 eV. With an acceleration voltage of about 25 kV and Al-foils (20 to 35 ug/cmsup2) as converter, we obtained counting efficiences of 70 to 85 percent. The design and performance of the detector system, employing six foils with different sensitive areas, are described and discussed in detail. (author)

  18. Electron-electron coincidence spectroscopies at surfaces

    International Nuclear Information System (INIS)

    Stefani, G.; Iacobucci, S.; Ruocco, A.; Gotter, R.

    2002-01-01

    In the past 20 years, a steadily increasing number of electron-electron coincidence experiments on atoms and molecules have contributed to a deeper understanding of electron-electron correlation effects. In more recent years this technique has been extended to the study of solid surfaces. This class of one photon IN two electrons OUT experiments will be discussed with an emphasis on grazing incidence geometry, that is expected to be particularly suited for studying surfaces. The crucial question of which is the dominant mechanism that leads to ejection of pairs of electron from the surface will be addressed. It will be shown that, depending on the kinematics chosen, the correlated behaviour of the pairs of electrons detected might be singled out from independent particle one

  19. Minicomputer system for radiochemical analysis by coincidence spectrometry

    International Nuclear Information System (INIS)

    Brauer, F.P.; Fager, J.E.

    1979-01-01

    Minicomputer-based coincidence analysis methods have been developed for use in performing radiochemical analysis by high-resolution x- and gamma-ray coincidence spectrometry. This paper describes the data-acquisition and analysis methods develolped for qualitative and quantitative analyses of coincidence spectrometric data. Data-acquisition capabilities include both direct multiparameter pulse-height analysis and buffered list-mode acquisition

  20. Standardisation of {sup 18}F by a coincidence method using full solid angle detectors

    Energy Technology Data Exchange (ETDEWEB)

    Nedjadi, Youcef, E-mail: youcef.nedjadi@chuv.c [Institut de Radiophysique Appliquee, Grand Pre 1, 1007 Lausanne (Switzerland); Bailat, Claude; Caffari, Yvan; Bochud, Francois [Institut de Radiophysique Appliquee, Grand Pre 1, 1007 Lausanne (Switzerland)

    2010-07-15

    A solution of {sup 18}F was standardised with a 4{pi}{beta}-4{pi}{gamma} coincidence counting system in which the beta detector is a one-inch diameter cylindrical UPS89 plastic scintillator, positioned at the bottom of a well-type 5''x5'' NaI(Tl) gamma-ray detector. Almost full detection efficiency-which was varied downwards electronically-was achieved in the beta-channel. Aliquots of this {sup 18}F solution were also measured using 4{pi}{gamma} NaI(Tl) integral counting and Monte Carlo calculated efficiencies as well as the CIEMAT-NIST method. Secondary measurements of the same solution were also performed with an IG11 ionisation chamber whose equivalent activity is traceable to the Systeme International de Reference through the contribution IRA-METAS made to it in 2001; IRA's degree of equivalence was found to be close to the key comparison reference value (KCRV). The {sup 18}F activity predicted by this coincidence system agrees closely with the ionisation chamber measurement and is compatible within one standard deviation of the other primary measurements. This work demonstrates that our new coincidence system can standardise short-lived radionuclides used in nuclear medicine.

  1. Soudan 2 muons in coincidence with BATSE bursts

    International Nuclear Information System (INIS)

    DeMuth, D.M.; Marshak, M.L.; Wagner, G.L.

    1994-01-01

    We explore the possibilities of statistically significant temporal and spatial coincidences between underground muons at Soudan 2 and Gamma Ray Bursts at the GRO-BATSE detector. Our search uses data from the April 91 to March 92 BATSE burst catalog to seek correlations within a 100 second window of coincidence. Sixteen of 180 BATSE triggers have temporally and spatially coincident muons in the Soudan 2 detector. We estimate the chance probability of each coincidence assuming the null hypothesis on the basis of a study of the multiplicities of spatially coincident muons observed over a two day period centered on the time of burst

  2. Logistic regression for dichotomized counts.

    Science.gov (United States)

    Preisser, John S; Das, Kalyan; Benecha, Habtamu; Stamm, John W

    2016-12-01

    Sometimes there is interest in a dichotomized outcome indicating whether a count variable is positive or zero. Under this scenario, the application of ordinary logistic regression may result in efficiency loss, which is quantifiable under an assumed model for the counts. In such situations, a shared-parameter hurdle model is investigated for more efficient estimation of regression parameters relating to overall effects of covariates on the dichotomous outcome, while handling count data with many zeroes. One model part provides a logistic regression containing marginal log odds ratio effects of primary interest, while an ancillary model part describes the mean count of a Poisson or negative binomial process in terms of nuisance regression parameters. Asymptotic efficiency of the logistic model parameter estimators of the two-part models is evaluated with respect to ordinary logistic regression. Simulations are used to assess the properties of the models with respect to power and Type I error, the latter investigated under both misspecified and correctly specified models. The methods are applied to data from a randomized clinical trial of three toothpaste formulations to prevent incident dental caries in a large population of Scottish schoolchildren. © The Author(s) 2014.

  3. Platelet Count and Plateletcrit

    African Journals Online (AJOL)

    strated that neonates with late onset sepsis (bacteremia after 3 days of age) had a dramatic increase in MPV and. PDW18. We hypothesize that as the MPV and PDW increase and platelet count and PCT decrease in sick children, intui- tively, the ratio of MPV to PCT; MPV to Platelet count,. PDW to PCT, PDW to platelet ...

  4. EcoCount

    Directory of Open Access Journals (Sweden)

    Phillip P. Allen

    2014-05-01

    Full Text Available Techniques that analyze biological remains from sediment sequences for environmental reconstructions are well established and widely used. Yet, identifying, counting, and recording biological evidence such as pollen grains remain a highly skilled, demanding, and time-consuming task. Standard procedure requires the classification and recording of between 300 and 500 pollen grains from each representative sample. Recording the data from a pollen count requires significant effort and focused resources from the palynologist. However, when an adaptation to the recording procedure is utilized, efficiency and time economy improve. We describe EcoCount, which represents a development in environmental data recording procedure. EcoCount is a voice activated fully customizable digital count sheet that allows the investigator to continuously interact with a field of view during the data recording. Continuous viewing allows the palynologist the opportunity to remain engaged with the essential task, identification, for longer, making pollen counting more efficient and economical. EcoCount is a versatile software package that can be used to record a variety of environmental evidence and can be installed onto different computer platforms, making the adoption by users and laboratories simple and inexpensive. The user-friendly format of EcoCount allows any novice to be competent and functional in a very short time.

  5. Clean Hands Count

    Medline Plus

    Full Text Available ... starting stop Loading... Watch Queue Queue __count__/__total__ It’s YouTube. Uninterrupted. Loading... Want music and videos with ... ads? Get YouTube Red. Working... Not now Try it free Find out why Close Clean Hands Count ...

  6. Counting It Twice.

    Science.gov (United States)

    Schattschneider, Doris

    1991-01-01

    Provided are examples from many domains of mathematics that illustrate the Fubini Principle in its discrete version: the value of a summation over a rectangular array is independent of the order of summation. Included are: counting using partitions as in proof by pictures, combinatorial arguments, indirect counting as in the inclusion-exclusion…

  7. Evaluation of in-plant neutron coincidence counters for the measurement of molten salt extraction residues

    International Nuclear Information System (INIS)

    Langner, D.G.; Russo, P.A.; Wachter, J.R.

    1993-01-01

    Americium is extracted from plutonium by a molten salt extraction (MSE) process. The residual americium-laden salts are a significant waste stream in this pyrochemical purification process. Rapid assay of MSE residues is desirable to minimize the exposure of personnel to these often high-level emissions. However, the quantitative assay of plutonium in MSE residues is difficult. Variable, unknown (a,n) rates and variable emitted-neutron energy spectra preclude the use of standard neutron coincidence counting techniques with old-generation neutron coincidence counters. Gamma-ray assay methods have not been successful with some residues because of random lumps of plutonium metal. In this paper, we present measurements of MSE residues with two state-of-the-art neutron coincidence counters at the Los Alamos Plutonium Processing Facility: an in-line counter built for the assay of bulk waste material and the pyrochemical multiplicity counter that underwent test and evaluation at that facility. Both of these counters were designed to minimize the effects on measurements of variations in the sample geometry and variable energy spectra of emitted neutrons. These results are compared to measurements made with an HLNCII and with a 20-yr-old in-line well counter. The latter two counters are not optimized in ft sense. We conclude that the newer counters provide significantly improved assay results. The pyrochemical multiplicity counter operated in the conventional coincidence mode provided the best assays overall

  8. Performance Evaluation of the Neutron Coincidence Counter for the Advanced Spent Fuel Conditioning Process

    International Nuclear Information System (INIS)

    Lee, S.Y.; Li, T.K.; Menlove, Howard O.; Kim, H.D.; Ko, W.I.; Park, S.W.

    2005-01-01

    The Advanced Spent Fuel Conditioning Process (ACP) is a pyrochemical dry reprocessing technique to convert oxide-type spent nuclear fuel into a metallic form. The Korea Atomic Energy Research Institute (KAERI) has been developing this technology for the purpose of spent fuel management and is planning to perform a lab-scale demonstration in 2006. With this technology, a significant reduction of the volume and heat load of spent fuel is expected, which could decrease the burden of safety and economics. In this study, MCNPX code calculations were carried out to estimate the performance of a neutron coincidence counter designed for measruement of the process materials in the pilot-scale ACP facility. To verify the design requirement, the singles and doubles counting rates of the detectors were simulated with the latest coincidence capability of the MCNPX code. Then, the precision of the coincidence measurements were evaluated on various process materials from the ACP. It was verified that the performance of the neutron coincidence counter could meet the design criteria for all samples in the ACP, and the material accounting system for the pilot-scale ACP facility could meet the IAEA safeguards goals.

  9. Calculation of coincidence summing corrections for a specific small soil sample geometry

    Energy Technology Data Exchange (ETDEWEB)

    Helmer, R.G.; Gehrke, R.J.

    1996-10-01

    Previously, a system was developed at the INEL for measuring the {gamma}-ray emitting nuclides in small soil samples for the purpose of environmental monitoring. These samples were counted close to a {approx}20% Ge detector and, therefore, it was necessary to take into account the coincidence summing that occurs for some nuclides. In order to improve the technical basis for the coincidence summing corrections, the authors have carried out a study of the variation in the coincidence summing probability with position within the sample volume. A Monte Carlo electron and photon transport code (CYLTRAN) was used to compute peak and total efficiencies for various photon energies from 30 to 2,000 keV at 30 points throughout the sample volume. The geometry for these calculations included the various components of the detector and source along with the shielding. The associated coincidence summing corrections were computed at these 30 positions in the sample volume and then averaged for the whole source. The influence of the soil and the detector shielding on the efficiencies was investigated.

  10. True coincidence summing correction and mathematical efficiency modeling of a well detector

    Energy Technology Data Exchange (ETDEWEB)

    Jäderström, H., E-mail: henrik.jaderstrom@canberra.com [CANBERRA Industries Inc., 800 Research Parkway, Meriden, CT 06450 (United States); Mueller, W.F. [CANBERRA Industries Inc., 800 Research Parkway, Meriden, CT 06450 (United States); Atrashkevich, V. [Stroitely St 4-4-52, Moscow (Russian Federation); Adekola, A.S. [CANBERRA Industries Inc., 800 Research Parkway, Meriden, CT 06450 (United States)

    2015-06-01

    True coincidence summing (TCS) occurs when two or more photons are emitted from the same decay of a radioactive nuclide and are detected within the resolving time of the gamma ray detector. TCS changes the net peak areas of the affected full energy peaks in the spectrum and the nuclide activity is rendered inaccurate if no correction is performed. TCS is independent of the count rate, but it is strongly dependent on the peak and total efficiency, as well as the characteristics of a given nuclear decay. The TCS effects are very prominent for well detectors because of the high efficiencies, and make accounting for TCS a necessity. For CANBERRA's recently released Small Anode Germanium (SAGe) well detector, an extension to CANBERRA's mathematical efficiency calibration method (In Situ Object Calibration Software or ISOCS, and Laboratory SOurceless Calibration Software or LabSOCS) has been developed that allows for calculation of peak and total efficiencies for SAGe well detectors. The extension also makes it possible to calculate TCS corrections for well detectors using the standard algorithm provided with CANBERRAS's Spectroscopy software Genie 2000. The peak and total efficiencies from ISOCS/LabSOCS have been compared to MCNP with agreements within 3% for peak efficiencies and 10% for total efficiencies for energies above 30 keV. A sample containing Ra-226 daughters has been measured within the well and analyzed with and without TCS correction and applying the correction factor shows significant improvement of the activity determination for the energy range 46–2447 keV. The implementation of ISOCS/LabSOCS for well detectors offers a powerful tool for efficiency calibration for these detectors. The automated algorithm to correct for TCS effects in well detectors makes nuclide specific calibration unnecessary and offers flexibility in carrying out gamma spectral analysis.

  11. K-chameleon and the coincidence problem

    International Nuclear Information System (INIS)

    Wei Hao; Cai Ronggen

    2005-01-01

    In this paper we present a hybrid model of k-essence and chameleon, named as k-chameleon. In this model, due to the chameleon mechanism, the directly strong coupling between the k-chameleon field and matters (cold dark matters and baryons) is allowed. In the radiation-dominated epoch, the interaction between the k-chameleon field and background matters can be neglected; the behavior of the k-chameleon therefore is the same as that of the ordinary k-essence. After the onset of matter domination, the strong coupling between the k-chameleon and matters dramatically changes the result of the ordinary k-essence. We find that during the matter-dominated epoch, only two kinds of attractors may exist: one is the familiar K attractor and the other is a completely new, dubbed C attractor. Once the Universe is attracted into the C attractor, the fraction energy densities of the k-chameleon Ω φ and dust matter Ω m are fixed and comparable, and the Universe will undergo a power-law accelerated expansion. One can adjust the model so that the K attractor does not appear. Thus, the k-chameleon model provides a natural solution to the cosmological coincidence problem

  12. Coincidence orientations of grains in hexagonal materials

    International Nuclear Information System (INIS)

    Grimmer, H.; Warrington, D.H.

    1986-06-01

    The connection between the rotation matrix in hexagonal lattice coordinates and an angle-axis quadruple is given. The multiplication law of quadruples is derived. It corresponds to multiplying two matrices and gives the effect of two successive rotations. The relation is given between two quadruples that describe the same relative orientation of two lattices due to their hexagonal symmetry; a unique standard description of the relative orientation is proposed. The restrictions satisfied by rotations generating coincidence site lattices (CSLs) are derived for any value of the axial ratio rho = c/a. It is shown that the law for cubic lattices, where the multiplicity SIGMA of the CSL was equal to the least common denominator of the elements of the rotation matrix, does not always hold for hexagonal lattices. A generalisation of this law to lattices of arbitrary symmetry is given and another, quicker method to determine SIGMA for hexagonal lattices is derived. Finally, convenient algorithms are described for determining bases of the CSL and the DSC lattice. (author)

  13. Complex action support from coincidences of couplings

    International Nuclear Information System (INIS)

    Nielsen, H.B.

    2011-01-01

    Our model (Refs. 1–7) with a complex action in a functional integral formulation with path integrals extending over all times, both past and future, is reviewed. Several numerical relations between coupling constants are presented as supporting evidence. The new evidence is that several more hitherto unexplained coincidences are explained by our model: (1) The "scale problem" is solved because the Higgs field expectation value is predicted to be very small compared to say some fundamental scale, that might be the Planck scale. (2) The Higgs VEV need not be just zero, but rather is predicted to be so that the running top-quark Yukawa coupling just is about to be unity at this scale; in this way the (weak) scale easily becomes "exponentially small." Instead of the top-Yukawa we should rather say the highest flavor Yukawa coupling here. These predictions are only achieved by allowing the principle of minimization of the imaginary part of the action SI(history) to a certain extent adjust some coupling constants in addition to the initial conditions. If supersymmetric partners are not found at LHC it would strengthen the need for a "solution" to the hierarchy problem in our direction of an explanation via a fine-tuning scheme inside the Standard Model, from say minimizing "the imaginary part of the action" in our complex action model. (author)

  14. Fast-neutron coincidence-counter manual

    International Nuclear Information System (INIS)

    Ensslin, N.; Atwell, T.L.; Lee, D.M.; Erkkila, B.; Marshall, R.S.; Morgan, A.; Shonrock, C.; Tippens, B.; Van Lyssel, T.

    1982-03-01

    The fast neutron counter (FNC) described in this report is a computer-based assay system employing fast-pulse counting instrumentation. It is installed below a glove box in the metal electrorefining area of the Los Alamos National Laboratory Plutonium Processing Facility. The instrument was designed to assay plutonium salts and residues from this process and to verify the mass of electrorefined metal. Los Alamos National Laboratory Groups Q-1, Q-3, and CMB-11 carried out a joint test and evaluation plan of this instrument between May 1978 and May 1979. The results of that evaluation, a description of the FNC, and operating instructions for further use are given in this report

  15. Counting skills intervention for low-performing first graders

    Directory of Open Access Journals (Sweden)

    Riikka Mononen

    2016-09-01

    Conclusion: A relatively short counting skills intervention that applied explicit teaching showed promising effects in improving low-performing children’s mathematical performance as a supplemental instruction.

  16. Clean Hands Count

    Medline Plus

    Full Text Available ... Clean Hands Count Centers for Disease Control and Prevention (CDC) Loading... Unsubscribe from Centers for Disease Control and Prevention (CDC)? Cancel Unsubscribe Working... Subscribe Subscribed Unsubscribe 65K ...

  17. Clean Hands Count

    Medline Plus

    Full Text Available ... Clean Hands Count Centers for Disease Control and Prevention (CDC) Loading... Unsubscribe from Centers for Disease Control and Prevention (CDC)? Cancel Unsubscribe Working... Subscribe Subscribed Unsubscribe 66K ...

  18. Housing Inventory Count

    Data.gov (United States)

    Department of Housing and Urban Development — This report displays the data communities reported to HUD about the nature of their dedicated homeless inventory, referred to as their Housing Inventory Count (HIC)....

  19. Scintillation counting apparatus

    International Nuclear Information System (INIS)

    Noakes, J.E.

    1978-01-01

    Apparatus is described for the accurate measurement of radiation by means of scintillation counters and in particular for the liquid scintillation counting of both soft beta radiation and gamma radiation. Full constructional and operating details are given. (UK)

  20. Allegheny County Traffic Counts

    Data.gov (United States)

    Allegheny County / City of Pittsburgh / Western PA Regional Data Center — Traffic sensors at over 1,200 locations in Allegheny County collect vehicle counts for the Pennsylvania Department of Transportation. Data included in the Health...

  1. Counting Knights and Knaves

    Science.gov (United States)

    Levin,Oscar; Roberts, Gerri M.

    2013-01-01

    To understand better some of the classic knights and knaves puzzles, we count them. Doing so reveals a surprising connection between puzzles and solutions, and highlights some beautiful combinatorial identities.

  2. Clean Hands Count

    Medline Plus

    Full Text Available ... why Close Clean Hands Count Centers for Disease Control and Prevention (CDC) Loading... Unsubscribe from Centers for Disease Control and Prevention (CDC)? Cancel Unsubscribe Working... Subscribe Subscribed ...

  3. Clean Hands Count

    Medline Plus

    Full Text Available ... stop Loading... Watch Queue Queue __count__/__total__ It’s YouTube. Uninterrupted. Loading... Want music and videos with zero ads? Get YouTube Red. Working... Not now Try it free Find ...

  4. The Kruskal Count

    OpenAIRE

    Lagarias, Jeffrey C.; Rains, Eric; Vanderbei, Robert J.

    2001-01-01

    The Kruskal Count is a card trick invented by Martin J. Kruskal in which a magician "guesses" a card selected by a subject according to a certain counting procedure. With high probability the magician can correctly "guess" the card. The success of the trick is based on a mathematical principle related to coupling methods for Markov chains. This paper analyzes in detail two simplified variants of the trick and estimates the probability of success. The model predictions are compared with simula...

  5. Testable solution of the cosmological constant and coincidence problems

    International Nuclear Information System (INIS)

    Shaw, Douglas J.; Barrow, John D.

    2011-01-01

    We present a new solution to the cosmological constant (CC) and coincidence problems in which the observed value of the CC, Λ, is linked to other observable properties of the Universe. This is achieved by promoting the CC from a parameter that must be specified, to a field that can take many possible values. The observed value of Λ≅(9.3 Gyrs) -2 [≅10 -120 in Planck units] is determined by a new constraint equation which follows from the application of a causally restricted variation principle. When applied to our visible Universe, the model makes a testable prediction for the dimensionless spatial curvature of Ω k0 =-0.0056(ζ b /0.5), where ζ b ∼1/2 is a QCD parameter. Requiring that a classical history exist, our model determines the probability of observing a given Λ. The observed CC value, which we successfully predict, is typical within our model even before the effects of anthropic selection are included. When anthropic selection effects are accounted for, we find that the observed coincidence between t Λ =Λ -1/2 and the age of the Universe, t U , is a typical occurrence in our model. In contrast to multiverse explanations of the CC problems, our solution is independent of the choice of a prior weighting of different Λ values and does not rely on anthropic selection effects. Our model includes no unnatural small parameters and does not require the introduction of new dynamical scalar fields or modifications to general relativity, and it can be tested by astronomical observations in the near future.

  6. Fractional counts-the simulation of low probability events

    International Nuclear Information System (INIS)

    Coldwell, R.L.; Lasche, G.P.; Jadczyk, A.

    2001-01-01

    The code RobSim has been added to RobWin.1 It simulates spectra resulting from gamma rays striking an array of detectors made up of different components. These are frequently used to set coincidence and anti-coincidence windows that decide if individual events are part of the signal. The first problem addressed is the construction of the detector. Then owing to the statistical nature of the responses of these elements there is a random nature in the response that can be taken into account by including fractional counts in the output spectrum. This somewhat complicates the error analysis, as Poisson statistics are no longer applicable

  7. Algorithm for counting large directed loops

    Energy Technology Data Exchange (ETDEWEB)

    Bianconi, Ginestra [Abdus Salam International Center for Theoretical Physics, Strada Costiera 11, 34014 Trieste (Italy); Gulbahce, Natali [Theoretical Division and Center for Nonlinear Studies, Los Alamos National Laboratory, NM 87545 (United States)

    2008-06-06

    We derive a Belief-Propagation algorithm for counting large loops in a directed network. We evaluate the distribution of the number of small loops in a directed random network with given degree sequence. We apply the algorithm to a few characteristic directed networks of various network sizes and loop structures and compare the algorithm with exhaustive counting results when possible. The algorithm is adequate in estimating loop counts for large directed networks and can be used to compare the loop structure of directed networks and their randomized counterparts.

  8. Xe isotope detection and discrimination using beta spectroscopy with coincident gamma spectroscopy

    Science.gov (United States)

    Reeder, P. L.; Bowyer, T. W.

    1998-02-01

    Beta spectroscopic techniques show promise of significant improvements for a beta-gamma coincidence counter that is part of a system for analyzing Xe automatically separated from air. The previously developed counting system for 131mXe, 133mXe, 133gXe, and 135gXe can be enhanced to give additional discrimination between these Xe isotopes by using the plastic scintillation sample cell as a beta spectrometer to resolve the conversion electron peaks. The automated system will be a key factor in monitoring the Comprehensive Test Ban Treaty.

  9. Principle of coincidence method and application in activity measurement

    International Nuclear Information System (INIS)

    Li Mou; Dai Yihua; Ni Jianzhong

    2008-01-01

    The basic principle of coincidence method was discussed. The basic principle was generalized by analysing the actual example, and the condition in theory of coincidence method was brought forward. The cause of variation of efficiency curve and the effect of dead-time in activity measurement were explained using the above principle and condition. This principle of coincidence method provides the foundation in theory for activity measurement. (authors)

  10. Operations manual for the megachannel gamma-ray coincidence system

    International Nuclear Information System (INIS)

    Ruhter, W.

    1977-01-01

    To aid in the study of nuclear structures, a megachannel pulse-height coincidence analysis system on a PDP-8 computer was constructed. The system digitizes the energies of coincident gamma-rays and stores the resultant information on a moving-head disk. The system uses a minicomputer to sort and store gamma-gamma coincident information on line. The megachannel system and how to use it are described

  11. Application of coincidence Doppler-broadening spectroscopy to different carbon phases

    International Nuclear Information System (INIS)

    Ito, Y.; Djourelov, N.; Suzuki, T.; Kondo, K.; Ito, Y.; Shantarovich, V.; Onoe, J.

    2004-01-01

    Coincidence Doppler-broadening spectroscopy was applied to C60 and C70 fullerenes and other carbon phases, such as nanotubes and graphites. Remarkable differences were observed in the Doppler-broadening of the positron annihilation γ-rays in these materials, which reflect the different densities distribution of the momentum for electrons annihilated with positrons. This would be caused by the different composition of the π and σ electrons in annihilation with positrons. This result shows the sensitivity of the coincidence Doppler-broadening method to determine the density distribution of electrons sampled by positrons. (orig.)

  12. Coincidence Imaging and interference with coherent Gaussian beams

    Institute of Scientific and Technical Information of China (English)

    CAI Yang-jian; ZHU Shi-yao

    2006-01-01

    we present a theoretical study of coincidence imaging and interference with coherent Gaussian beams The equations for the coincidence image formation and interference fringes are derived,from which it is clear that the imaging is due to the corresponding focusing in the two paths .The quality and visibility of the images and fringes can be high simultaneously.The nature of the coincidence imaging and interference between quantum entangled photon pairs and coherent Gaussian beams are different .The coincidence image with coherent Gaussian beams is due to intensity-intensity correspondence,a classical nature,while that with entangled photon pairs is due to the amplitude correlation a quantum nature.

  13. Field test and evaluation of the passive neutron coincidence collar for prototype fast reactor fuel subassemblies

    International Nuclear Information System (INIS)

    Menlove, H.O.; Keddar, A.

    1982-08-01

    The passive neutron Coincidence Collar, which was developed for the verification of plutonium content in fast reactor fuel subassemblies, has been field tested using Prototype Fast Reactor fuel. For passive applications, the system measures the 240 Pu-effective mass from the spontaneous fission rate, and in addition, a self-interrogation technique is used to determine the fissile content in the subassembly. Both the passive and active modes were evaluated at the Windscale Works in the United Kingdom. The results of the tests gave a standard deviation 0.75% for the passive count and 3 to 7% for the active measurement for a 1000-s counting time. The unit will be used in the future for the verification of plutonium in fresh fuel assemblies

  14. Low White Blood Cell Count

    Science.gov (United States)

    Symptoms Low white blood cell count By Mayo Clinic Staff A low white blood cell count (leukopenia) is a decrease ... of white blood cell (neutrophil). The definition of low white blood cell count varies from one medical ...

  15. Determination of true coincidence correction factors using Monte-Carlo simulation techniques

    Directory of Open Access Journals (Sweden)

    Chionis Dionysios A.

    2014-01-01

    Full Text Available Aim of this work is the numerical calculation of the true coincidence correction factors by means of Monte-Carlo simulation techniques. For this purpose, the Monte Carlo computer code PENELOPE was used and the main program PENMAIN was properly modified in order to include the effect of the true coincidence phenomenon. The modified main program that takes into consideration the true coincidence phenomenon was used for the full energy peak efficiency determination of an XtRa Ge detector with relative efficiency 104% and the results obtained for the 1173 keV and 1332 keV photons of 60Co were found consistent with respective experimental ones. The true coincidence correction factors were calculated as the ratio of the full energy peak efficiencies was determined from the original main program PENMAIN and the modified main program PENMAIN. The developed technique was applied for 57Co, 88Y, and 134Cs and for two source-to-detector geometries. The results obtained were compared with true coincidence correction factors calculated from the "TrueCoinc" program and the relative bias was found to be less than 2%, 4%, and 8% for 57Co, 88Y, and 134Cs, respectively.

  16. A practical method for determining γ-ray full-energy peak efficiency considering coincidence-summing and self-absorption corrections for the measurement of environmental samples after the Fukushima reactor accident

    Energy Technology Data Exchange (ETDEWEB)

    Shizuma, Kiyoshi, E-mail: shizuma@hiroshima-u.ac.jp [Graduate School of Engineering, Hiroshima University, Higashi-Hiroshima 739-8527 (Japan); Oba, Yurika; Takada, Momo [Graduate School of Integrated Arts and Sciences, Hiroshima University, Higashi-Hiroshima 739-8521 (Japan)

    2016-09-15

    A method for determining the γ-ray full-energy peak efficiency at positions close to three Ge detectors and at the well port of a well-type detector was developed for measuring environmental volume samples containing {sup 137}Cs, {sup 134}Cs and {sup 40}K. The efficiency was estimated by considering two correction factors: coincidence-summing and self-absorption corrections. The coincidence-summing correction for a cascade transition nuclide was estimated by an experimental method involving measuring a sample at the far and close positions of a detector. The derived coincidence-summing correction factors were compared with those of analytical and Monte Carlo simulation methods and good agreements were obtained. Differences in the matrix of the calibration source and the environmental sample resulted in an increase or decrease of the full-energy peak counts due to the self-absorption of γ-rays in the sample. The correction factor was derived as a function of the densities of several matrix materials. The present method was applied to the measurement of environmental samples and also low-level radioactivity measurements of water samples using the well-type detector.

  17. A gamma-gamma coincidence/anticoincidence spectrometer for low-level cosmogenic (22)Na/(7)Be activity ratio measurement.

    Science.gov (United States)

    Zhang, Weihua; Ungar, Kurt; Stukel, Matthew; Mekarski, Pawel

    2014-04-01

    In this study, a digital gamma-gamma coincidence/anticoincidence spectrometer was developed and examined for low-level cosmogenic (22)Na and (7)Be in air-filter sample monitoring. The spectrometer consists of two bismuth germanate scintillators (BGO) and an XIA LLC Digital Gamma Finder (DGF)/Pixie-4 software and card package. The spectrometer design allows a more selective measurement of (22)Na with a significant background reduction by gamma-gamma coincidence events processing. Hence, the system provides a more sensitive way to quantify trace amounts of (22)Na than normal high resolution gamma spectrometry providing a critical limit of 3 mBq within a 20 h count. The use of a list-mode data acquisition technique enabled simultaneous determination of (22)Na and (7)Be activity concentrations using a single measurement by coincidence and anticoincidence mode respectively. Copyright © 2014 Elsevier Ltd. All rights reserved.

  18. Alpha scintillation radon counting

    International Nuclear Information System (INIS)

    Lucas, H.F. Jr.

    1977-01-01

    Radon counting chambers which utilize the alpha-scintillation properties of silver activated zinc sulfide are simple to construct, have a high efficiency, and, with proper design, may be relatively insensitive to variations in the pressure or purity of the counter filling. Chambers which were constructed from glass, metal, or plastic in a wide variety of shapes and sizes were evaluated for the accuracy and the precision of the radon counting. The principles affecting the alpha-scintillation radon counting chamber design and an analytic system suitable for a large scale study of the 222 Rn and 226 Ra content of either air or other environmental samples are described. Particular note is taken of those factors which affect the accuracy and the precision of the method for monitoring radioactivity around uranium mines

  19. Interpretation of galaxy counts

    International Nuclear Information System (INIS)

    Tinsely, B.M.

    1980-01-01

    New models are presented for the interpretation of recent counts of galaxies to 24th magnitude, and predictions are shown to 28th magnitude for future comparison with data from the Space Telescope. The results supersede earlier, more schematic models by the author. Tyson and Jarvis found in their counts a ''local'' density enhancement at 17th magnitude, on comparison with the earlier models; the excess is no longer significant when a more realistic mixture of galaxy colors is used. Bruzual and Kron's conclusion that Kron's counts show evidence for evolution at faint magnitudes is confirmed, and it is predicted that some 23d magnitude galaxies have redshifts greater than unity. These may include spheroidal systems, elliptical galaxies, and the bulges of early-type spirals and S0's, seen during their primeval rapid star formation

  20. A magnetic-lens - mini-orange coincidence spectrometer

    International Nuclear Information System (INIS)

    Bargholtz, C.; Holmberg, L.; Ruus, N.; Tegner, P.E.; Weiss, G.

    1997-04-01

    A coincidence spectrometer consisting of a Gerholm type magnetic lens and a permanent magnet mini-orange spectrometer is described. Electron-electron or electron-positron coincidences may be registered in various angular settings. The spectrometer has been developed mainly to search for anomalous contributions to Bhabha scattering or positrons and is at present used for such studies. 6 refs

  1. An Inexpensive Coincidence Circuit for the Pasco Geiger Sensors

    CERN Document Server

    Fichera, F; Librizzi, F; Riggi, F

    2005-01-01

    A simple coincidence circuit was devised to carry out educational coincidence experiments involving the use of Geiger counters. The system was tested by commercially available Geiger sensors from PASCO, and is intended to be used in collaboration with high school students and teachers

  2. Identification of peaks in multidimensional coincidence {gamma}-ray spectra

    Energy Technology Data Exchange (ETDEWEB)

    Morhac, Miroslav E-mail: fyzimiro@savba.sk; Kliman, Jan; Matousek, Vladislav; Veselsky, Martin; Turzo, Ivan

    2000-03-21

    In the paper a new algorithm to find peaks in two, three and multidimensional spectra, measured in large multidetector {gamma}-ray arrays, is derived. Given the dimension m, the algorithm is selective to m-fold coincidence peaks. It is insensitive to intersections of lower-fold coincidences, hereinafter called ridges.

  3. Identification of peaks in multidimensional coincidence γ-ray spectra

    International Nuclear Information System (INIS)

    Morhac, Miroslav; Kliman, Jan; Matousek, Vladislav; Veselsky, Martin; Turzo, Ivan

    2000-01-01

    In the paper a new algorithm to find peaks in two, three and multidimensional spectra, measured in large multidetector γ-ray arrays, is derived. Given the dimension m, the algorithm is selective to m-fold coincidence peaks. It is insensitive to intersections of lower-fold coincidences, hereinafter called ridges

  4. Development of the software dead time methodology for the 4πβ-γ software coincidence system analysis program

    International Nuclear Information System (INIS)

    Toledo, Fabio de; Brancaccio, Franco; Dias, Mauro da Silva

    2009-01-01

    The Laboratorio de Metrologia Nuclear - LMN, Nuclear Metrology Laboratory -, at IPEN-CNEN/SP, Sao Paulo, Brazil, developed a new Software Coincidence System (SCS) for 4πβ-γ radioisotope standardization. SCS is composed by the data acquisition hardware, for the coincidence data recording, and the coincidence data analysis program that performs the radioactive activity calculation for the target sample. Due to hardware intrinsic signal sampling characteristics, multiple undesired data recording occurs from a single saturated pulse. Also pulse pileup leads to bad data recording. As the beta counting rates are much greater than the gamma ones, due to the high 4π geometry beta detecting efficiencies, the beta counting significantly increases because of multiple pulse recordings, resulting in a respective increasing in the calculated activity value. In order to minimize such bad recordings effect, a software dead time value was introduced in the coincidence analysis program, under development at LMN, discarding multiple recordings, due to pulse pileup or saturation. This work presents the methodology developed to determine the optimal software dead time data value, for better accuracy results attaining, and discusses the results, pointing to software improvement possibilities. (author)

  5. Cerenkov counting and Cerenkov-scintillation counting with high refractive index organic liquids using a liquid scintillation counter

    Energy Technology Data Exchange (ETDEWEB)

    Wiebe, L I; Helus, F; Maier-Borst, W [Deutsches Krebsforschungszentrum, Heidelberg (Germany, F.R.). Inst. fuer Nuklearmedizin

    1978-06-01

    /sup 18/F and /sup 14/C radioactivity was measured in methyl salicylate (MS), a high refractive index hybrid Cherenkov-scintillation generating medium, using a liquid scintillation counter. At concentrations of up to 21.4%, in MS, dimethyl sulfoxide (DMSO) quenched /sup 14/C fluorescence, and with a 10-fold excess of DMSO over MS, /sup 18/F count rates were reduced below that for DMSO alone, probably as a result of concentration-independent self-quenching due to 'dark-complex' formation. DMSO in lower concentrations did not reduce the counting efficiency of /sup 18/F in MS. Nitrobenzene was a concentration-dependent quencher for both /sup 14/C and /sup 18/F in MS. Chlorobenzene (CB) and DMSO were both found to be weak Cherenkov generators with /sup 18/F. Counting efficiencies for /sup 18/F in MS, CB, and DMSO were 50.3, 7.8 and 4.3% respectively in the coincidence counting mode, and 58.1, 13.0 and 6.8% in the singles mode. /sup 14/C efficiencies were 14.4 and 22.3% for coincidence and singles respectively, and 15.3 and 42.0% using a modern counter designed for coincidence and single photon counting. The high /sup 14/C and /sup 18/F counting efficiency in MS are discussed with respect to excitation mechanism, on the basis of quench and channels ratios changes observed. It is proposed that MS functions as an efficient Cherenkov-scintillation generator for high-energy beta emitters such as /sup 18/F, and as a low-efficiency scintillator for weak beta emitting radionuclides such as /sup 14/C.

  6. Cerenkov counting and Cerenkov-scintillation counting with high refractive index organic liquids using a liquid scintillation counter

    International Nuclear Information System (INIS)

    Wiebe, L.I.; Helus, F.; Maier-Borst, W.

    1978-01-01

    18 F and 14 C radioactivity was measured in methyl salicylate (MS), a high refractive index hybrid Cherenkov-scintillation generating medium, using a liquid scintillation counter. At concentrations of up to 21.4%, in MS, dimethyl sulfoxide (DMSO) quenched 14 C fluorescence, and with a 10-fold excess of DMSO over MS, 18 F count rates were reduced below that for DMSO alone, probably as a result of concentration-independent self-quenching due to 'dark-complex' formation. DMSO in lower concentrations did not reduce the counting efficiency of 18 F in MS. Nitrobenzene was a concentration-dependent quencher for both 14 C and 18 F in MS. Chlorobenzene (CB) and DMSO were both found to be weak Cherenkov generators with 18 F. Counting efficiencies for 18 F in MS, CB, and DMSO were 50.3, 7.8 and 4.3% respectively in the coincidence counting mode, and 58.1, 13.0 and 6.8% in the singles mode. 14 C efficiencies were 14.4 and 22.3% for coincidence and singles respectively, and 15.3 and 42.0% using a modern counter designed for coincidence and single photon counting. The high 14 C and 18 F counting efficiency in MS are discussed with respect to excitation mechanism, on the basis of quench and channels ratios changes observed. It is proposed that MS functions as an efficient Cherenkov-scintillation generator for high-energy beta emitters such as 18 F, and as a low-efficiency scintillator for weak beta emitting radionuclides such as 14 C. (author)

  7. Accuracy in activation analysis: count rate effects

    International Nuclear Information System (INIS)

    Lindstrom, R.M.; Fleming, R.F.

    1980-01-01

    The accuracy inherent in activation analysis is ultimately limited by the uncertainty of counting statistics. When careful attention is paid to detail, several workers have shown that all systematic errors can be reduced to an insignificant fraction of the total uncertainty, even when the statistical limit is well below one percent. A matter of particular importance is the reduction of errors due to high counting rate. The loss of counts due to random coincidence (pulse pileup) in the amplifier and to digitization time in the ADC may be treated as a series combination of extending and non-extending dead times, respectively. The two effects are experimentally distinct. Live timer circuits in commercial multi-channel analyzers compensate properly for ADC dead time for long-lived sources, but not for pileup. Several satisfactory solutions are available, including pileup rejection and dead time correction circuits, loss-free ADCs, and computed corrections in a calibrated system. These methods are sufficiently reliable and well understood that a decaying source can be measured routinely with acceptably small errors at a dead time as high as 20 percent

  8. Continuous monitoring α-activity on aerosol filters by the pseudo-coincidence-technique. Explicitly taking into account the short lived Po-218 activity; Kontinuierliche Ueberwachung der α-Aktivitaet eines Aerosolfilters mit der Pseudokoinzidenzmesstechnik. Explizite Beruecksichtigung der kurzlebigen Po-218 Aktivitaetsbeitraaege

    Energy Technology Data Exchange (ETDEWEB)

    Kraut, W.; Schwarz, W. [Duale Hochschule Baden-Wuerttemberg (DHBW), Karlsruhe (Germany). Studiengang Sicherheitswesen; Kraut, B. [Berthold Technologies GmbH und Co.KG, Bad Wildbad (Germany)

    2015-07-01

    Pseudo-coincidence-technique is applied to continuous monitoring of α-activity on aerosolfilters by proportional counters. Filter activity can markedly increase or decrease by changing air conditions especially by the amount of short lived Po-218 activity. Conditions of constant proportions of activity concentrations for the short lived species for operating this technique are seldom fulfilled. The dynamic behavior of artificial (long lived) and natural (short lived) activity is mathematically modelled and the measured moving count rates are analyzed under this model by a multivariate regression analysis for activity concentrations of artificial resp. short lived activity. Results are compared to standard recommendations of DIN ISO 11929.

  9. Clean Hands Count

    Medline Plus

    Full Text Available ... Queue __count__/__total__ It’s YouTube. Uninterrupted. Loading... Want music and videos with zero ads? Get YouTube Red. ... 824 views 1:36 Wash 'Em - Hand Hygiene Music Video - Duration: 5:46. Jefferson Health 409,492 ...

  10. Clean Hands Count

    Medline Plus

    Full Text Available ... Queue __count__/__total__ It’s YouTube. Uninterrupted. Loading... Want music and videos with zero ads? Get YouTube Red. ... 786 views 1:36 Wash 'Em - Hand Hygiene Music Video - Duration: 5:46. Jefferson Health 413,702 ...

  11. Clean Hands Count

    Medline Plus

    Full Text Available ... Queue __count__/__total__ It’s YouTube. Uninterrupted. Loading... Want music and videos with zero ads? Get YouTube Red. ... 414 views 3:10 Wash 'Em - Hand Hygiene Music Video - Duration: 5:46. Thomas Jefferson University & Jefferson ...

  12. Clean Hands Count

    Medline Plus

    Full Text Available ... Queue __count__/__total__ It’s YouTube. Uninterrupted. Loading... Want music and videos with zero ads? Get YouTube Red. ... 869 views 1:36 Wash 'Em - Hand Hygiene Music Video - Duration: 5:46. Jefferson Health 410,052 ...

  13. Clean Hands Count

    Medline Plus

    Full Text Available ... Queue __count__/__total__ It’s YouTube. Uninterrupted. Loading... Want music and videos with zero ads? Get YouTube Red. ... 460 views 3:10 Wash 'Em - Hand Hygiene Music Video - Duration: 5:46. Thomas Jefferson University & Jefferson ...

  14. Clean Hands Count

    Medline Plus

    Full Text Available ... Queue __count__/__total__ It’s YouTube. Uninterrupted. Loading... Want music and videos with zero ads? Get YouTube Red. ... 741 views 3:10 Wash 'Em - Hand Hygiene Music Video - Duration: 5:46. Jefferson Health 410,052 ...

  15. Clean Hands Count

    Medline Plus

    Full Text Available ... Queue __count__/__total__ It’s YouTube. Uninterrupted. Loading... Want music and videos with zero ads? Get YouTube Red. ... 029 views 3:10 Wash 'Em - Hand Hygiene Music Video - Duration: 5:46. Jefferson Health 411,974 ...

  16. Clean Hands Count

    Medline Plus

    Full Text Available ... Queue __count__/__total__ It’s YouTube. Uninterrupted. Loading... Want music and videos with zero ads? Get YouTube Red. ... 396 views 3:10 Wash 'Em - Hand Hygiene Music Video - Duration: 5:46. Thomas Jefferson University & Jefferson ...

  17. Clean Hands Count

    Medline Plus

    Full Text Available ... Queue __count__/__total__ It’s YouTube. Uninterrupted. Loading... Want music and videos with zero ads? Get YouTube Red. ... 094 views 1:19 Wash 'Em - Hand Hygiene Music Video - Duration: 5:46. Jefferson Health 411,974 ...

  18. Clean Hands Count

    Medline Plus

    Full Text Available ... Queue __count__/__total__ It’s YouTube. Uninterrupted. Loading... Want music and videos with zero ads? Get YouTube Red. ... 319 views 3:10 Wash 'Em - Hand Hygiene Music Video - Duration: 5:46. Jefferson Health 410,052 ...

  19. Clean Hands Count

    Medline Plus

    Full Text Available ... Queue __count__/__total__ It’s YouTube. Uninterrupted. Loading... Want music and videos with zero ads? Get YouTube Red. ... 585 views 3:10 Wash 'Em - Hand Hygiene Music Video - Duration: 5:46. Jefferson Health 413,097 ...

  20. Detection and counting systems

    International Nuclear Information System (INIS)

    Abreu, M.A.N. de

    1976-01-01

    Detection devices based on gaseous ionization are analysed, such as: electroscopes ionization chambers, proportional counters and Geiger-Mueller counters. Scintillation methods are also commented. A revision of the basic concepts in electronics is done and the main equipment for counting is detailed. In the study of gama spectrometry, scintillation and semiconductor detectors are analysed [pt

  1. Clean Hands Count

    Medline Plus

    Full Text Available ... Queue __count__/__total__ It’s YouTube. Uninterrupted. Loading... Want music and videos with zero ads? Get YouTube Red. ... 384 views 1:19 Wash 'Em - Hand Hygiene Music Video - Duration: 5:46. Thomas Jefferson University & Jefferson ...

  2. Clean Hands Count

    Medline Plus

    Full Text Available ... Queue __count__/__total__ It’s YouTube. Uninterrupted. Loading... Want music and videos with zero ads? Get YouTube Red. ... 285 views 1:36 Wash 'Em - Hand Hygiene Music Video - Duration: 5:46. Jefferson Health 410,052 ...

  3. Clean Hands Count

    Medline Plus

    Full Text Available ... Queue __count__/__total__ It’s YouTube. Uninterrupted. Loading... Want music and videos with zero ads? Get YouTube Red. ... 033 views 1:36 Wash 'Em - Hand Hygiene Music Video - Duration: 5:46. Jefferson Health 410,052 ...

  4. Reticulocyte Count Test

    Science.gov (United States)

    ... htm. (2004 Summer). Immature Reticulocyte Fraction(IRF). The Pathology Center Newsletter v9(1). [On-line information]. Available ... Company, Philadelphia, PA [18th Edition]. Levin, M. (2007 March 8, Updated). Reticulocyte Count. MedlinePlus Medical Encyclopedia [On- ...

  5. Clean Hands Count

    Medline Plus

    Full Text Available ... is starting stop Loading... Watch Queue Queue __count__/__total__ It’s YouTube. Uninterrupted. Loading... Want music and videos ... empower patients to play a role in their care by asking or reminding healthcare providers to clean ...

  6. Radiation intensity counting system

    International Nuclear Information System (INIS)

    Peterson, R.J.

    1982-01-01

    A method is described of excluding the natural dead time of the radiation detector (or eg Geiger-Mueller counter) in a ratemeter counting circuit, thus eliminating the need for dead time corrections. Using a pulse generator an artificial dead time is introduced which is longer than the natural dead time of the detector. (U.K.)

  7. Clean Hands Count

    Medline Plus

    Full Text Available ... Queue __count__/__total__ It’s YouTube. Uninterrupted. Loading... Want music and videos with zero ads? Get YouTube Red. ... 043 views 1:36 Wash 'Em - Hand Hygiene Music Video - Duration: 5:46. Jefferson Health 411,292 ...

  8. Calorie count - fast food

    Science.gov (United States)

    ... GO About MedlinePlus Site Map FAQs Customer Support Health Topics Drugs & Supplements Videos & Tools Español You Are Here: Home → Medical Encyclopedia → Calorie count - fast food URL of this page: //medlineplus.gov/ency/patientinstructions/ ...

  9. Measurement of the neutron lifetime by counting trapped protons

    International Nuclear Information System (INIS)

    Byrne, J.; Dawber, P.G.; Spain, J.A.; Williams, A.P.; Dewey, M.S.; Gilliam, D.M.; Greene, G.L.; Lamaze, G.P.; Scott, R.D.; Pauwels, J.; Eykens, R.; Lamberty, A.

    1990-01-01

    The neutron lifetime τ n has been measured by counting decay protons stored in a Penning trap whose magnetic axis coincided with a neutron-beam axis. The result of the measurement is τ n =893.6±5.3 s, which agrees well with the value predicted by precise measurements of the β-decay asymmetry parameter A and the standard model

  10. Line identification studies using traditional techniques and wavelength coincidence statistics

    International Nuclear Information System (INIS)

    Cowley, C.R.; Adelman, S.J.

    1990-01-01

    Traditional line identification techniques result in the assignment of individual lines to an atomic or ionic species. These methods may be supplemented by wavelength coincidence statistics (WCS). The strength and weakness of these methods are discussed using spectra of a number of normal and peculiar B and A stars that have been studied independently by both methods. The present results support the overall findings of some earlier studies. WCS would be most useful in a first survey, before traditional methods have been applied. WCS can quickly make a global search for all species and in this way may enable identifications of an unexpected spectrum that could easily be omitted entirely from a traditional study. This is illustrated by O I. WCS is a subject to well known weakness of any statistical technique, for example, a predictable number of spurious results are to be expected. The danger of small number statistics are illustrated. WCS is at its best relative to traditional methods in finding a line-rich atomic species that is only weakly present in a complicated stellar spectrum

  11. Low level GAMMA0 spectrometry by beta-gamma coincidence

    International Nuclear Information System (INIS)

    Grigorescu, E.L.; Luca, A.; Razdolescu, A.C.; Ivan, C.

    1999-01-01

    Low level gamma spectrometry has a wide application, especially in environmental monitoring. Two variants, based on a beta-gamma coincidence technique, were studied. The equipment was composed of a beta detector and a Ge(Li) gamma detector (6% - relative efficiency), with the associated electronics. The gamma rays are recorded by the multichannel analyzer (4096 channels) only if the associated beta particles, which precede the gamma transitions, are registered in coincidence. Two types of beta detectors were used: plastic and liquid scintillators. In both cases, an external lead shield of 5 cm thick was used. The integral gamma background (50-1700 KeV) was reduced about 85 and 50 times, respectively. The corresponding MDA (Minimum Detectable Activity) values decreased about 1.5 and (3-7) times, respectively. The 2π sr plastic beta detector was placed on top the Ge(Li). The sample was inserted between the two detectors. The measurement time was 10 4 s. A 4π sr detector, built of the same material, was also studied, but it proved to be less advantageous because the background was reduced only 16 times; for a MDA reduction similar with that of the 2π sr variant, a longer measurement was needed (3.10 4 s). The other type of beta detector used, was a liquid scintillator. The dissolving of the samples in scintillator ensures a 4π sr measurement geometry. The vials with scintillator (10 ml volume) were placed on top the Ge(Li) and visualised by the photocathode of a phototube. This setup was surrounded by an enclosure which prevent the light penetration. The measurement time was 10 4 s. The only difficulty encountered in this low level measurement method is the accurate determination of the beta efficiency. A limitation is the possibility to measure only small mass samples. These variants are more simple and cheaper than others, previously studied. The advantage of the method is obvious when, instead of low MDA values, shorter measurement times are preferred. The

  12. Software correction of scatter coincidence in positron CT

    International Nuclear Information System (INIS)

    Endo, M.; Iinuma, T.A.

    1984-01-01

    This paper describes a software correction of scatter coincidence in positron CT which is based on an estimation of scatter projections from true projections by an integral transform. Kernels for the integral transform are projected distributions of scatter coincidences for a line source at different positions in a water phantom and are calculated by Klein-Nishina's formula. True projections of any composite object can be determined from measured projections by iterative applications of the integral transform. The correction method was tested in computer simulations and phantom experiments with Positologica. The results showed that effects of scatter coincidence are not negligible in the quantitation of images, but the correction reduces them significantly. (orig.)

  13. Low-resource synchronous coincidence processor for positron emission tomography

    International Nuclear Information System (INIS)

    Sportelli, Giancarlo; Belcari, Nicola; Guerra, Pedro; Santos, Andres

    2011-01-01

    We developed a new FPGA-based method for coincidence detection in positron emission tomography. The method requires low device resources and no specific peripherals in order to resolve coincident digital pulses within a time window of a few nanoseconds. This method has been validated with a low-end Xilinx Spartan-3E and provided coincidence resolutions lower than 6 ns. This resolution depends directly on the signal propagation properties of the target device and the maximum available clock frequency, therefore it is expected to improve considerably on higher-end FPGAs.

  14. Dynamic imaging with coincidence gamma camera

    International Nuclear Information System (INIS)

    Elhmassi, Ahmed

    2008-01-01

    In this paper we develop a technique to calculate dynamic parameters from data acquired using gamma-camera PET (gc PET). Our method is based on an algorithm development for dynamic SPECT, which processes all decency projection data simultaneously instead of reconstructing a series of static images individually. The algorithm was modified to account for the extra data that is obtained with gc PET (compared with SPEC). The method was tested using simulated projection data for both a SPECT and a gc PET geometry. These studies showed the ability of the code to reconstruct simulated data with a varying range of half-lives. The accuracy of the algorithm was measured in terms of the reconstructed half-life and initial activity for the simulated object. The reconstruction of gc PET data showed improvement in half-life and activity compared to SPECT data of 23% and 20%, respectively (at 50 iterations). The gc PET algorithm was also tested using data from an experimental phantom and finally, applied to a clinical dataset, where the algorithm was further modified to deal with the situation where the activity in certain pixels decreases and then increases during the acquisition. (author)

  15. Calculation of the n-th coincidences frequency

    International Nuclear Information System (INIS)

    Mercier, C.

    1959-01-01

    Events can occur randomly with a given frequency. Each event lasts a Θ-time. During this Θ-time other events can occur. A coincidence beginning of order n at a t-time is when an event occurs while n other events already occurred between t-Θ and t. In this work the frequency of coincidence beginnings with an order greater than or equal to n is established

  16. Determination iodine in biological materials using instrumental neutron activation and anti-coincidence gamma-ray spectrometry

    International Nuclear Information System (INIS)

    Zhang, W.H.; Chatt, A.

    1997-01-01

    Iodine is an element of interest in nutritional research. Its lower limit of safe and adequate daily dietary intake for adults varies between 150 and 200 micrograms per day. In the present study, an epithermal instrumental neutron activation analysis (EINAA) method in conjunction with anti-coincidence counting has been developed for the determination of ppb levels of iodine in individual food items. Typically 200-300 mg of a sample are irradiated for 10 or 20 minutes at the Dalhousie University SLOWPOKE-2 reactor in an epithermal flux of 1x10 11 n cm -2 s -1 , followed by 1 min decay and then counting for 30 min. The 443-keV gamma-ray of 128 I is used for measuring iodine content by anti-coincidence counting. The anti-coincidence spectrometer consists of a 25% HPGe detector surrounded by a 10''x10'' NaI(TI) annulus and a 3''x3'' NaI(TI) plug. This system has a peak-to-Compton ratio of about 650 to 1 for the 661.6-keV photopeak of 137 Cs. The Compton background resulting from the scattering of many gamma-rays of energies higher than 443 keV can be reduced by a factor of about 4 using anti-coincidence counting compared to conventional counting. The detection limit for iodine can be improved by a factor of 2 to 5 depending on the sample matrix, dead time, position of the annulus and counting geometry among several other factors.The lowest detection limit of 5 ppb can be achieved for low-salt foods. This limit is comparable to that obtained by a preconcentration NAA (PNAA) method. However, a detection limit of 20 ppb is more realistic for samples containing high amounts of Na, Cl and Al. The results obtained for many reference materials are in good agreement with the certified values and those reported by the PNAA method. Details of the methods and results will be reported

  17. Determination iodine in biological materials using instrumental neutron activation and anti-coincidence gamma-ray spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, W.H.; Chatt, A. [Dalhousie University, Halifax, Nova Scotia (Canada). Radiochemistry Research Laboratory

    1997-10-01

    Iodine is an element of interest in nutritional research. Its lower limit of safe and adequate daily dietary intake for adults varies between 150 and 200 micrograms per day. In the present study, an epithermal instrumental neutron activation analysis (EINAA) method in conjunction with anti-coincidence counting has been developed for the determination of ppb levels of iodine in individual food items. Typically 200-300 mg of a sample are irradiated for 10 or 20 minutes at the Dalhousie University SLOWPOKE-2 reactor in an epithermal flux of 1x10{sup 11} n cm{sup -2} s{sup -1}, followed by 1 min decay and then counting for 30 min. The 443-keV gamma-ray of {sup 128}I is used for measuring iodine content by anti-coincidence counting. The anti-coincidence spectrometer consists of a 25% HPGe detector surrounded by a 10``x10`` NaI(TI) annulus and a 3``x3`` NaI(TI) plug. This system has a peak-to-Compton ratio of about 650 to 1 for the 661.6-keV photopeak of {sup 137}Cs. The Compton background resulting from the scattering of many gamma-rays of energies higher than 443 keV can be reduced by a factor of about 4 using anti-coincidence counting compared to conventional counting. The detection limit for iodine can be improved by a factor of 2 to 5 depending on the sample matrix, dead time, position of the annulus and counting geometry among several other factors.The lowest detection limit of 5 ppb can be achieved for low-salt foods. This limit is comparable to that obtained by a preconcentration NAA (PNAA) method. However, a detection limit of 20 ppb is more realistic for samples containing high amounts of Na, Cl and Al. The results obtained for many reference materials are in good agreement with the certified values and those reported by the PNAA method. Details of the methods and results will be reported 6 refs., 2 tabs.

  18. It counts who counts: an experimental evaluation of the importance of observer effects on spotlight count estimates

    DEFF Research Database (Denmark)

    Sunde, Peter; Jessen, Lonnie

    2013-01-01

    observers with respect to their ability to detect and estimate distance to realistic animal silhouettes at different distances. Detection probabilities were higher for observers experienced in spotlighting mammals than for inexperienced observers, higher for observers with a hunting background compared...... with non-hunters and decreased as function of age but were independent of sex or educational background. If observer-specific detection probabilities were applied to real counting routes, point count estimates from inexperienced observers without a hunting background would only be 43 % (95 % CI, 39...

  19. Analysis of General Power Counting Rules in Effective Field Theory

    CERN Document Server

    Gavela, B M; Manohar, A V; Merlo, L

    2016-01-01

    We derive the general counting rules for a quantum effective field theory (EFT) in $\\mathsf{d}$ dimensions. The rules are valid for strongly and weakly coupled theories, and predict that all kinetic energy terms are canonically normalized. They determine the energy dependence of scattering cross sections in the range of validity of the EFT expansion. The size of cross sections is controlled by the $\\Lambda$ power counting of EFT, not by chiral counting, even for chiral perturbation theory ($\\chi$PT). The relation between $\\Lambda$ and $f$ is generalized to $\\mathsf{d}$ dimensions. We show that the naive dimensional analysis $4\\pi$ counting is related to $\\hbar$ counting. The EFT counting rules are applied to $\\chi$PT, to Standard Model EFT and to the non-trivial case of Higgs EFT, which combines the $\\Lambda$ and chiral counting rules within a single theory.

  20. CalCOFI Egg Counts

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Fish egg counts and standardized counts for eggs captured in CalCOFI icthyoplankton nets (primarily vertical [Calvet or Pairovet], oblique [bongo or ring nets], and...

  1. Results obtained with LEGe detectors applied for partial-body counting in the low-energy range (3-150 keV); Erfahrungen mit LEGe-Detektoren bei Teilkoerpermessungen im Bereich niedriger Energien (3-150 keV)

    Energy Technology Data Exchange (ETDEWEB)

    Dettmann, K. [Bundesamt fuer Strahlenschutz, Berlin (Germany)

    1997-12-01

    Due to a change in the field of duties, the Phoswich detector hitherto used for organ and partial-body scanning for measuring low-energy {gamma} radiation and X-radiation had to be replaced by a modern detector system. A key application of the new system is detection and in vivo measurement of {sup 210}Pb in the human skeleton. This method of measuring {sup 210}Pb as a long-lived daughter product of radon is applied for retrospective assessment of radiation doses emanatingfrom the radon decay chain, applied to former uranium miners (WISMUT) and members of the population living or having lived in houses with high radon concentrations. The bone activities to be expected from relevant exposures are only slightly above those of the normal {sup 210}Pb content in the bones (10-30 Bq), and the Phoswich detector system was not able to detect incorporated activity down to these low levels. The new system was also tested for its suitability and efficiency in detecting radionuclide depositions in body organs, particularly the actinides that are difficult to identify, in compliance with the relevant regulatory guide. (orig./CB) [Deutsch] In der Inkorporationsmessstelle musste auf Grund neuer Aufgabenstellungen der fuer Organ- und Teilkoerpermessungen zum Nachweis niederenergetischer {gamma}- und Roentgenstrahlung eingesetzte Phoswich-Detektor durch ein modernes Detektorsystem ersetzt werden. Ein wichtiges Einsatzgebiet des neuen Systems ist die Bestimmung von {sup 210}Pb im menschlichen Skelett ueber In-vivo-Messungen. Diese Methode der Bestimmung von {sup 210}Pb als langlebiges Folgeprodukt des Radons dient der retrospektiven Ermittlung der Exposition durch Radon-Zerfallsprodukte bei ehemaligen Uranbergleuten (WISMUT) und Personen aus der Bevoelkerung, die in Wohnhaeusern mit hohen Radonkonzentrationen leben bzw. gelebt haben. Die fuer relevante Expositionen zu erwartenden Skelettaktivitaeten liegen nur wenig ueber dem {sup 210}Pb-Normalgehalt (10-30 Bq). Mit einer

  2. Counting statistics in radioactivity measurements

    International Nuclear Information System (INIS)

    Martin, J.

    1975-01-01

    The application of statistical methods to radioactivity measurement problems is analyzed in several chapters devoted successively to: the statistical nature of radioactivity counts; the application to radioactive counting of two theoretical probability distributions, Poisson's distribution law and the Laplace-Gauss law; true counting laws; corrections related to the nature of the apparatus; statistical techniques in gamma spectrometry [fr

  3. Do your syringes count?

    International Nuclear Information System (INIS)

    Brewster, K.

    2002-01-01

    Full text: This study was designed to investigate anecdotal evidence that residual Sestamibi (MIBI) activity vaned in certain situations. For rest studies different brands of syringes were tested to see if the residuals varied. The period of time MIBI doses remained in the syringe between dispensing and injection was also considered as a possible source of increased residual counts. Stress Mibi syringe residual activities were measured to assess if the method of stress test affected residual activity. MIBI was reconstituted using 13 Gbq of Technetium in 3mls of normal saline then boiled for 10 minutes. Doses were dispensed according to department protocol and injected via cannula. Residual syringes were collected for three syringe types. In each case the barrel and plunger were measured separately. As the syringe is flushed during the exercise stress test and not the pharmacological stress test the chosen method was recorded. No relationship was demonstrated between the time MIBI remained in a syringe prior to injection and residual activity. Residual activity was not affected by method of stress test used. Actual injected activity can be calculated if the amount of activity remaining in the syringe post injection is known. Imaging time can be adjusted for residual activity to optimise count statistics. Preliminary results in this study indicate there is no difference in residual activity between syringe brands.Copyright (2002) The Australian and New Zealand Society of Nuclear Medicine Inc

  4. Analysis of spatial count data using Kalman smoothing

    DEFF Research Database (Denmark)

    Dethlefsen, Claus

    2007-01-01

    We consider spatial count data from an agricultural field experiment. Counts of weed plants in a field have been recorded in a project on precision farming. Interest is in mapping the weed intensity so that the dose of herbicide applied at any location can be adjusted to the amount of weed present...

  5. CDL, a Precise, Low-Cost Coincidence Detector Latch

    Directory of Open Access Journals (Sweden)

    Ralf Joost

    2015-12-01

    Full Text Available The electronic detection of the coincidence of two events is still a key ingredient for high-performance applications, such as Positron Emission Tomography and Quantum Optics. Such applications are demanding, since the precision of their calculations and thus their conclusions directly depend on the duration of the interval in which two events are considered coincidental. This paper proposes a new circuitry, called coincidence detector latch (CDL, which is derived from standard RS latches. The CDL has the following advantages: low complexity, fully synthesizable, and high scalability. Even in its simple implementation, it achieves a coincidence window width as short as 115 ps, which is more than 10 times better than that reported by recent research.

  6. Photoion Auger-electron coincidence measurements near threshold

    International Nuclear Information System (INIS)

    Levin, J.C.; Biedermann, C.; Keller, N.; Liljeby, L.; Short, R.T.; Sellin, I.A.; Lindle, D.W.

    1990-01-01

    The vacancy cascade which fills an atomic inner-shell hole is a complex process which can proceed by a variety of paths, often resulting in a broad distribution of photoion charge states. We have measured simplified argon photoion charge distributions by requiring a coincidence with a K-LL or K-LM Auger electron, following K excitation with synchrotron radiation, as a function of photon energy, and report here in detail the argon charge distributions coincident with K-L 1 L 23 Auger electrons. The distributions exhibit a much more pronounced photon-energy dependence than do the more complicated non-coincident spectra. Resonant excitation of the K electron to np levels, shakeoff of these np electrons by subsequent decay processes, double-Auger decay, and recapture of the K photoelectron through postcollision interaction occur with significant probability. 17 refs

  7. True coincidence summing correction determination for 214Bi principal gamma lines in NORM samples

    International Nuclear Information System (INIS)

    Haddad, Kh.

    2014-01-01

    The gamma lines 609.3 and 1,120.3 keV are two of the most intensive γ emissions of 214 Bi, but they have serious true coincidence summing (TCS) effects due to the complex decay schemes with multi-cascading transitions. TCS effects cause inaccurate count rate and hence erroneous results. A simple and easy experimental method for determination of TCS correction of 214 Bi gamma lines was developed in this work using naturally occurring radioactive material samples. Height efficiency and self attenuation corrections were determined as well. The developed method has been formulated theoretically and validated experimentally. The corrections problems were solved simply with neither additional standard source nor simulation skills. (author)

  8. The underwater coincidence counter for plutonium measurements in mixed-oxide fuel assemblies manual

    International Nuclear Information System (INIS)

    Eccleston, G.W.; Menlove, H.O.; Abhold, M.; Baker, M.; Pecos, J.

    1999-01-01

    This manual describes the Underwater Coincidence Counter (UWCC) that has been designed for the measurement of plutonium in mixed-oxide (MOX) fuel assemblies prior to irradiation. The UWCC uses high-efficiency 3 He neutron detectors to measure the spontaneous-fission and induced-fission rates in the fuel assembly. Measurements can be made on MOX fuel assemblies in air or underwater. The neutron counting rate is analyzed for singles, doubles, and triples time correlations to determine the 240 Pu effective mass per unit length of the fuel assembly. The system can verify the plutonium loading per unit length to a precision of less than 1% in a measurement time of 2 to 3 minutes. System design, components, performance tests, and operational characteristics are described in this manual

  9. Digital data recording system for the 4 πβ-γ coincidence apparatus

    International Nuclear Information System (INIS)

    Shaha, V.V.; Srivastava, P.K.

    1975-01-01

    The data recording system for the 4πβ-γ coincidence apparatus consists of three scalers, a timer, a day-clock, a print control unit and a Hewlett-Packard printer. The print control unit serves as an interface unit as well as generates necessary electronic commands for starting, scanning, recycling and actuating the printer. It also generates the run number and identification number. It has made the data recording and recycling completely automatic. The report describes the data recording system which has been in continuous use since March 1973. Brief description of the scalers, the timer, the day-clock and the printer is given. The print control unit is described and the working of the data handling, scanning and cycle counting sections is explained. (author)

  10. Quantification of 235U and 238U activity concentrations for undeclared nuclear materials by a digital gamma-gamma coincidence spectroscopy.

    Science.gov (United States)

    Zhang, Weihua; Yi, Jing; Mekarski, Pawel; Ungar, Kurt; Hauck, Barry; Kramer, Gary H

    2011-06-01

    The purpose of this study is to investigate the possibility of verifying depleted uranium (DU), natural uranium (NU), low enriched uranium (LEU) and high enriched uranium (HEU) by a developed digital gamma-gamma coincidence spectroscopy. The spectroscopy consists of two NaI(Tl) scintillators and XIA LLC Digital Gamma Finder (DGF)/Pixie-4 software and card package. The results demonstrate that the spectroscopy provides an effective method of (235)U and (238)U quantification based on the count rate of their gamma-gamma coincidence counting signatures. The main advantages of this approach over the conventional gamma spectrometry include the facts of low background continuum near coincident signatures of (235)U and (238)U, less interference from other radionuclides by the gamma-gamma coincidence counting, and region-of-interest (ROI) imagine analysis for uranium enrichment determination. Compared to conventional gamma spectrometry, the method offers additional advantage of requiring minimal calibrations for (235)U and (238)U quantification at different sample geometries. Crown Copyright © 2011. Published by Elsevier Ltd. All rights reserved.

  11. Modal Logics with Counting

    Science.gov (United States)

    Areces, Carlos; Hoffmann, Guillaume; Denis, Alexandre

    We present a modal language that includes explicit operators to count the number of elements that a model might include in the extension of a formula, and we discuss how this logic has been previously investigated under different guises. We show that the language is related to graded modalities and to hybrid logics. We illustrate a possible application of the language to the treatment of plural objects and queries in natural language. We investigate the expressive power of this logic via bisimulations, discuss the complexity of its satisfiability problem, define a new reasoning task that retrieves the cardinality bound of the extension of a given input formula, and provide an algorithm to solve it.

  12. Data acquisition and processing system for coincidence measurements

    International Nuclear Information System (INIS)

    Li Xu

    1990-07-01

    An instrument has been designed for the absolute measurement of radioactivity with 4πβ(PC)-γ coincidence. The instrument can be used as a standard device for the radioactivity measurement in metrology laboratories. Also it can be used in the nuclear science and engineering research for absolute measurement of nuclear decay rate. The control of the system dead time and coincidence resolving time is digitized. The precision can reach ±2 ns. For data acquisition and communication the normalizing GPIB interface system technique is adopted. The measuring error caused by this instrument itself can be better than ±0.02%

  13. Standardization of portable assay instrumentation: the neutron-coincidence tree

    International Nuclear Information System (INIS)

    Menlove, H.O.

    1983-01-01

    Standardization of portable neutron assay instrumentation has been achieved by using the neutron coincidence technique as a common basis for a wide range of instruments and applications. The electronics originally developed for the High-Level Neutron Coincidence Counter has been adapted to both passive- and active-assay instrumentation for field verification of bulk plutonium, inventory samples, pellets, powders, nitrates, high-enriched uranium, and materials-testing-reactor, light-water-reactor, and mixed-oxide fuel assemblies. The family of detectors developed at Los Alamos National Laboratory and their performance under in-field conditions are described. 16 figures, 3 tables

  14. Automatic classification of gammas-gamma coincidence matrices

    International Nuclear Information System (INIS)

    Los Arcos Merino, J. M.; Gonzalez, J. A.

    1978-01-01

    The information obtained during a coincidence experiment, recorded on magnetic tape by a MULTI-8 minicomputer, is transferred to a new tape in 36 bit words, using the program LEC0M8. The classification in two dimensional matrix form is carried out off-line, on a magnetic disk file, by the program CLAFI. On finishing classification one obtains a copy of the coincidence matrix on the second magnetic tape. Both programs are written to be processed in that order with the UNIVAC 1106 computer of J.E.N. (Author) 4 refs

  15. Automatic classification of gamma-gamma coincidence matrices

    International Nuclear Information System (INIS)

    Los Arcos Merino, J.M.; Gonzalez Gonzalez, J.A.

    1978-01-01

    The information obtained during a coincidence experiment, recorded on magnetic tape by a Multi-8 minicomputer, is transferred to a new tape in 36 bit words, using the program Lecom8. The classification in two dimensional matrix form is carried out off-line, on a magnetic disk file, by the program Clafi. On finishing classification one obtains a copy of the coincidence matrix on the second magnetic tape. Both programs are written to be processed in that order with the Univac 1106 computer of J.E.N. (author)

  16. Disintegration rate of Tc -99m and In -111 radioactive solutions in coincidence systems

    International Nuclear Information System (INIS)

    Brito, Andreia Barreto de

    2011-01-01

    The 111 In and 99 mTc standardization in a 4πβ-γ coincidence system is described. The 111 In was produced by the reaction of 111 Cd (p, n) 111 In in the cyclotron. The 111 In decays with a half life of 2.8 days by electron capture process, populating the excited levels of 111 Cd, emitting two main gamma rays with energies of 171 keV and 245 keV. The 99m Tc decay with a half life of 6.007 h for isomeric transition, from the radioactive decay of 99 Mo. 111 In standardization was carried out in a 4πβ-γ system, consisted of a gas flow proportional counter with 4π geometry coupled to a pair of NaI(Tl) scintillation counter with conventional electronics. The gamma window was set comprising the (171 keV + 245 keV) total absorption energy peaks. The choice of the window was based on the analysis of the extrapolation curves prediction, obtained by Monte Carlo simulation. The 99 mTc standardization has been accomplished by the 4πβ-γ coincidence method using a thin window proportional counter in a 4π geometry coupled to a single NaI(Tl) scintillation counter. The beta efficiency was varied by electronic discrimination using a software coincidence counting system (SCS). Two windows were selected for the gamma channel: one at 140 keV gamma ray and the other at 20 keV X ray total absorption peaks. The result of the experimental activity of 111 In two solutions agree with the results obtained by Monte Carlo simulation. The experimental activities of 99m Tc for the two gamma windows are in agreement within the experimental uncertainty, indicating that the adopted methodology is adequate. (author)

  17. Fast procedures for coincidence-summing correction in γ-ray spectrometry

    International Nuclear Information System (INIS)

    De Felice, Pierino; Angelini, Paola; Fazio, Aldo; Biagini, Roberto

    2000-01-01

    Simplified and fast procedures for coincidence-summing correction in γ-ray spectrometry were investigated. These procedures are based on the usual theoretical expressions of the correction factors, but differ in the determination of the total efficiency curve based on the following approximations: (a) replacement, below the knee efficiency value, of the total efficiency by the full-energy peak efficiency; and (b) use of linear interpolations (in log-log plot) between only two experimental points above the knee efficiency value; or (c) assumption of a peak-to-total efficiency ratio independent on the counting geometry; or (d) assumption of a constant relation between the peak-to-total efficiency ratios and the photoelectric-to-total cross section ratios. The above approximations were separately assumed for determination of the coincidence-summing correction factors for nuclides with complex decay scheme ( 133 Ba, 134 Cs, 152 Eu) and for 60 Co and 88 Y measured on a 15% relative efficiency p-type coaxial HPGe detector, for three source-detector geometries: point source placed on top of and at 10 cm from the detector window, and 1 l Marinelli beaker filled with aqueous solution. The results were compared with those based on more accurate experimental determinations of the total efficiency curve from measurements of standard sources of eight different single-γ-ray emitters. The usefulness of each simplified procedure is evaluated with respect to its accuracy and to the reduction of the number of standard sources and measurement time

  18. Counting statistics in low level radioactivity measurements fluctuating counting efficiency

    International Nuclear Information System (INIS)

    Pazdur, M.F.

    1976-01-01

    A divergence between the probability distribution of the number of nuclear disintegrations and the number of observed counts, caused by counting efficiency fluctuation, is discussed. The negative binominal distribution is proposed to describe the probability distribution of the number of counts, instead of Poisson distribution, which is assumed to hold for the number of nuclear disintegrations only. From actual measurements the r.m.s. amplitude of counting efficiency fluctuation is estimated. Some consequences of counting efficiency fluctuation are investigated and the corresponding formulae are derived: (1) for detection limit as a function of the number of partial measurements and the relative amplitude of counting efficiency fluctuation, and (2) for optimum allocation of the number of partial measurements between sample and background. (author)

  19. Field test and evaluation of the IAEA coincidence collar for the measurement of unirradiated BWR fuel assemblies

    International Nuclear Information System (INIS)

    Menlove, H.O.; Keddar, A.

    1982-12-01

    The neutron coincidence counter has been field tested and evaluated for the measurement of boiling-water-reactor (BWR) fuel assemblies at the ASEA-ATOM Fuel Fabrication Facility. The system measures the 235 U content per unit length of full fuel assemblies using neutron interrogation and coincidence counting. The 238 U content is measured in the passive mode without the AmLi neutron interrogatioin source. The field tests included both standard production movable fuel rods to investigate enrichment and absorber variations. Results gave a response standard deviation of 0.9% for the active case and 2.1% for the passive case in 1000-s measurement times. 10 figures, 2 tables

  20. An Optimized Design of Single-Channel Beta-Gamma Coincidence Phoswich Detector by Geant4 Monte Carlo Simulations

    Directory of Open Access Journals (Sweden)

    Weihua Zhang

    2011-01-01

    Full Text Available An optimized single-channel phoswich well detector design has been proposed and assessed in order to improve beta-gamma coincidence measurement sensitivity of xenon radioisotopes. This newly designed phoswich well detector consists of a plastic beta counting cell (BC404 embedded in a CsI(Tl crystal coupled to a photomultiplier tube. The BC404 is configured in a cylindrical pipe shape to minimise light collection deterioration. The CsI(Tl crystal consists of a rectangular part and a semicylindrical scintillation part as a light reflector to increase light gathering. Compared with a PhosWatch detector, the final optimized detector geometry showed 15% improvement in the energy resolution of a 131mXe 129.4 keV conversion electron peak. The predicted beta-gamma coincidence efficiencies of xenon radioisotopes have also been improved accordingly.

  1. Method of summation of amplitudes of coinciding pulses from Ge(Li) detectors used to study cascades of gamma-transitions in (n,#betta#) reaction

    International Nuclear Information System (INIS)

    Bogdzel', A.A.; Vasil'eva, Eh.V.; Elizarov, O.I.

    1982-01-01

    Main performanes and peculiarities of spectrometer based on the coincidence pulse amplitude total-count method and containing two Ge(La) detectors with transmission neutron spectrometer - IBR-30 pulse reactor are considered. It is shown on the 35 Cl(n, #betta#) reaction that the method of summalion of amplitudes of coinciding pulses from the Ge(Li) detector can be used to study the cascades of two #betta#-transitions with a total energy similar to the neutron binding energy. The shape of the response function of this spectrometer was studied versus the energies of #betta#-transition cascades

  2. IMPECC, new 4 π β γ coincidence system

    International Nuclear Information System (INIS)

    Bouchard, J.; Chauvenet, B.; Vatin, R.

    1988-05-01

    The new 4 π β γ coincidence system IMPECC which uses an extensible dead time circuit common to both channels is described. Correction formulae which take into account the particularities of the electronics are also presented. The use of two ADC's and the symmetry in the two channels gives us a very powerful instrument when measuring complex decay scheme radionuclides [fr

  3. Optical Co-Incidence Gate | Srinivasulu | African Journal of Science ...

    African Journals Online (AJOL)

    The paper explains Optical co-incidence gate, realized using Unijunction transistors (UJT), Light emitting diodes (LED) and Photo-resistors (LDR), which works on 1.8Vdc instead of 3Vdc. The power dissipation of the designed gate is only 3 mW. This optical gate finds application in the field of Mechatronics, Instrumentation ...

  4. Positron two-photon annihilation coincidence technique: difference mode

    Energy Technology Data Exchange (ETDEWEB)

    Karol, P J; Klobuchar, R L [Carnegie-Mellon Univ., Pittsburgh, Pa. (USA). Dept. of Chemistry

    1978-05-01

    A difference (or comparative) mode in the measurement of two-photon coincidences from positron or positronium annihilation has been developed. The method can be used to advantage, particularly in gases, in determining annihilation parameters such as quenching cross sections for low concentration strongly quenching chemical species in a reference medium which is relatively non-quenching.

  5. Analysis of (HI, xnγ) coincidence spectra

    International Nuclear Information System (INIS)

    Pattabiraman, N.S.; Ghugre, S.S.; Chintalapudi, S.N.

    2000-01-01

    The increase in the sensitivity and the detection limits of the modern third generation gamma detector arrays, has made it necessary to properly understand and estimate the observed background in such experiments. The present paper extends the two algorithms to improve the genuine photo-peak-photo-peak coincident events of interest

  6. Chemical application of positron annihilation through triple coincidence measurement

    International Nuclear Information System (INIS)

    Yegnasubramanian, S.; Gangadharan, S.

    1982-01-01

    This report summarises the work on the application of triple coincidence measurement of annihilation radiation for providing chemical state information; the observations have been corroborated by angular correlation and Doppler broadening measurements and supplemented by the magnetic quenching in the angular correlation and peak-to-valley ratio in the Ge(Li) singles spectrum for the 511 keV line. (author)

  7. Beta-gamma counting system for Xe fission products

    International Nuclear Information System (INIS)

    Reeder, P.L.; Bowyer, T.W.; Perkins, R.W.

    1998-01-01

    A beta-gamma coincidence counting system has been developed for automated analysis of Xe gas samples separated from air. The Xe gas samples are contained in a cylindrical plastic scintillator cell located between two NaI(Tl) scintillation detectors. The X-ray and gamma spectra gated by coincident events in the plastic scintillator cell are recorded for each NaI(Tl) crystal. The characteristic signatures of the 131m Xe, 133g Xe, 133m Xe, and 135g Xe isotopes of interest for nuclear test-ban verification as well as the procedures and results of absolute efficiency measurements are described. A NaI(Tl) crystal with provision for 4 sample cells has been implemented for the system to be deployed in the field. Examples of data on ambient air samples in New York City obtained with the field prototype are presented. (author)

  8. Let's Make Data Count

    Science.gov (United States)

    Budden, A. E.; Abrams, S.; Chodacki, J.; Cruse, P.; Fenner, M.; Jones, M. B.; Lowenberg, D.; Rueda, L.; Vieglais, D.

    2017-12-01

    The impact of research has traditionally been measured by citations to journal publications and used extensively for evaluation and assessment in academia, but this process misses the impact and reach of data and software as first-class scientific products. For traditional publications, Article-Level Metrics (ALM) capture the multitude of ways in which research is disseminated and used, such as references and citations within social media and other journal articles. Here we present on the extension of usage and citation metrics collection to include other artifacts of research, namely datasets. The Make Data Count (MDC) project will enable measuring the impact of research data in a manner similar to what is currently done with publications. Data-level metrics (DLM) are a multidimensional suite of indicators measuring the broad reach and use of data as legitimate research outputs. By making data metrics openly available for reuse in a number of different ways, the MDC project represents an important first step on the path towards the full integration of data metrics into the research data management ecosystem. By assuring researchers that their contributions to scholarly progress represented by data corpora are acknowledged, data level metrics provide a foundation for streamlining the advancement of knowledge by actively promoting desirable best practices regarding research data management, publication, and sharing.

  9. LAWRENCE RADIATION LABORATORY COUNTING HANDBOOK

    Energy Technology Data Exchange (ETDEWEB)

    Group, Nuclear Instrumentation

    1966-10-01

    The Counting Handbook is a compilation of operational techniques and performance specifications on counting equipment in use at the Lawrence Radiation Laboratory, Berkeley. Counting notes have been written from the viewpoint of the user rather than that of the designer or maintenance man. The only maintenance instructions that have been included are those that can easily be performed by the experimenter to assure that the equipment is operating properly.

  10. Accurate disintegration-rate measurement of 55Fe by liquid scintillation counting

    International Nuclear Information System (INIS)

    Steyn, J.; Oberholzer, P.; Botha, S.M.

    1979-01-01

    A method involving liquid scintillation counting is described for the accurate measurement of disintegration rate of 55 Fe. The method is based on the use of calculated efficiency functions together with either of the nuclides 54 Mn and 51 Cr as internal standards for measurement of counting efficiencies by coincidence counting. The method was used by the NAC during a recent international intercomparison of radioactivity measurements, and a summary of the results obtained by nine participating laboratories is presented. A spread in results of several percent is evident [af

  11. SUMS Counts-Related Projects

    Data.gov (United States)

    Social Security Administration — Staging Instance for all SUMs Counts related projects including: Redeterminations/Limited Issue, Continuing Disability Resolution, CDR Performance Measures, Initial...

  12. Anthropology that counts

    DEFF Research Database (Denmark)

    Vaaben, Nana Katrine

    and is expected to deliver “practice oriented” research, preferably evidence based and ready to “apply” - or sometimes even in the case of action research supposedly “applied in the process”. The development opens the question of where the borders are between anthropology and consulting business, whether...... professional practices in schools, hospitals, and other welfare institutions that has to “apply research”, or could it also be the political levels, that were subject to “applications”? In any case, anthropology becomes extremely political, and has to find a position between different ideological knowledge...

  13. Development of an Apparatus for High-Resolution Auger Photoelectron Coincidence Spectroscopy (APECS) and Electron Ion Coincidence (EICO) Spectroscopy

    Science.gov (United States)

    Kakiuchi, Takuhiro; Hashimoto, Shogo; Fujita, Narihiko; Mase, Kazuhiko; Tanaka, Masatoshi; Okusawa, Makoto

    We have developed an electron electron ion coincidence (EEICO) apparatus for high-resolution Auger photoelectron coincidence spectroscopy (APECS) and electron ion coincidence (EICO) spectroscopy. It consists of a coaxially symmetric mirror electron energy analyzer (ASMA), a miniature double-pass cylindrical mirror electron energy analyzer (DP-CMA), a miniature time-of-flight ion mass spectrometer (TOF-MS), a magnetic shield, an xyz stage, a tilt-adjustment mechanism, and a conflat flange with an outer diameter of 203 mm. A sample surface was irradiated by synchrotron radiation, and emitted electrons were energy-analyzed and detected by the ASMA and the DP-CMA, while desorbed ions were mass-analyzed and detected by the TOF-MS. The performance of the new EEICO analyzer was evaluated by measuring Si 2p photoelectron spectra of clean Si(001)-2×1 and Si(111)-7×7, and by measuring Si-L23VV-Si-2p Auger photoelectron coincidence spectra (Si-L23VV-Si-2p APECS) of clean Si(001)-2×1.

  14. Liquid scintillation counting

    International Nuclear Information System (INIS)

    Bunge, F.

    1986-01-01

    The methods applied for quench corrections in LSC rely on radioactivity standard sources as reference materials. For determining the quenching effect effect, there are methods based on the sample channel ratio, or the spectral quench parameter determination, or determination of the H-number. Currently available LSC equipment is briefly described. (DG) [de

  15. Cascaded systems analysis of photon counting detectors.

    Science.gov (United States)

    Xu, J; Zbijewski, W; Gang, G; Stayman, J W; Taguchi, K; Lundqvist, M; Fredenberg, E; Carrino, J A; Siewerdsen, J H

    2014-10-01

    Photon counting detectors (PCDs) are an emerging technology with applications in spectral and low-dose radiographic and tomographic imaging. This paper develops an analytical model of PCD imaging performance, including the system gain, modulation transfer function (MTF), noise-power spectrum (NPS), and detective quantum efficiency (DQE). A cascaded systems analysis model describing the propagation of quanta through the imaging chain was developed. The model was validated in comparison to the physical performance of a silicon-strip PCD implemented on an experimental imaging bench. The signal response, MTF, and NPS were measured and compared to theory as a function of exposure conditions (70 kVp, 1-7 mA), detector threshold, and readout mode (i.e., the option for coincidence detection). The model sheds new light on the dependence of spatial resolution, charge sharing, and additive noise effects on threshold selection and was used to investigate the factors governing PCD performance, including the fundamental advantages and limitations of PCDs in comparison to energy-integrating detectors (EIDs) in the linear regime for which pulse pileup can be ignored. The detector exhibited highly linear mean signal response across the system operating range and agreed well with theoretical prediction, as did the system MTF and NPS. The DQE analyzed as a function of kilovolt (peak), exposure, detector threshold, and readout mode revealed important considerations for system optimization. The model also demonstrated the important implications of false counts from both additive electronic noise and charge sharing and highlighted the system design and operational parameters that most affect detector performance in the presence of such factors: for example, increasing the detector threshold from 0 to 100 (arbitrary units of pulse height threshold roughly equivalent to 0.5 and 6 keV energy threshold, respectively), increased the f50 (spatial-frequency at which the MTF falls to a value of

  16. Cascaded systems analysis of photon counting detectors

    International Nuclear Information System (INIS)

    Xu, J.; Zbijewski, W.; Gang, G.; Stayman, J. W.; Taguchi, K.; Carrino, J. A.; Lundqvist, M.; Fredenberg, E.; Siewerdsen, J. H.

    2014-01-01

    Purpose: Photon counting detectors (PCDs) are an emerging technology with applications in spectral and low-dose radiographic and tomographic imaging. This paper develops an analytical model of PCD imaging performance, including the system gain, modulation transfer function (MTF), noise-power spectrum (NPS), and detective quantum efficiency (DQE). Methods: A cascaded systems analysis model describing the propagation of quanta through the imaging chain was developed. The model was validated in comparison to the physical performance of a silicon-strip PCD implemented on an experimental imaging bench. The signal response, MTF, and NPS were measured and compared to theory as a function of exposure conditions (70 kVp, 1–7 mA), detector threshold, and readout mode (i.e., the option for coincidence detection). The model sheds new light on the dependence of spatial resolution, charge sharing, and additive noise effects on threshold selection and was used to investigate the factors governing PCD performance, including the fundamental advantages and limitations of PCDs in comparison to energy-integrating detectors (EIDs) in the linear regime for which pulse pileup can be ignored. Results: The detector exhibited highly linear mean signal response across the system operating range and agreed well with theoretical prediction, as did the system MTF and NPS. The DQE analyzed as a function of kilovolt (peak), exposure, detector threshold, and readout mode revealed important considerations for system optimization. The model also demonstrated the important implications of false counts from both additive electronic noise and charge sharing and highlighted the system design and operational parameters that most affect detector performance in the presence of such factors: for example, increasing the detector threshold from 0 to 100 (arbitrary units of pulse height threshold roughly equivalent to 0.5 and 6 keV energy threshold, respectively), increased the f 50 (spatial-frequency at

  17. Cascaded systems analysis of photon counting detectors

    Energy Technology Data Exchange (ETDEWEB)

    Xu, J.; Zbijewski, W.; Gang, G.; Stayman, J. W. [Department of Biomedical Engineering, Johns Hopkins University, Baltimore, Maryland 21205 (United States); Taguchi, K.; Carrino, J. A. [Russell H. Morgan Department of Radiology, Johns Hopkins University, Baltimore, Maryland 21205 (United States); Lundqvist, M.; Fredenberg, E. [Philips Healthcare, Solna 171 41 (Sweden); Siewerdsen, J. H., E-mail: jeff.siewerdsen@jhu.edu [Department of Biomedical Engineering, Johns Hopkins University, Baltimore, Maryland 21205 (United States); Russell H. Morgan Department of Radiology, Johns Hopkins University, Baltimore, Maryland 21205 (United States)

    2014-10-15

    Purpose: Photon counting detectors (PCDs) are an emerging technology with applications in spectral and low-dose radiographic and tomographic imaging. This paper develops an analytical model of PCD imaging performance, including the system gain, modulation transfer function (MTF), noise-power spectrum (NPS), and detective quantum efficiency (DQE). Methods: A cascaded systems analysis model describing the propagation of quanta through the imaging chain was developed. The model was validated in comparison to the physical performance of a silicon-strip PCD implemented on an experimental imaging bench. The signal response, MTF, and NPS were measured and compared to theory as a function of exposure conditions (70 kVp, 1–7 mA), detector threshold, and readout mode (i.e., the option for coincidence detection). The model sheds new light on the dependence of spatial resolution, charge sharing, and additive noise effects on threshold selection and was used to investigate the factors governing PCD performance, including the fundamental advantages and limitations of PCDs in comparison to energy-integrating detectors (EIDs) in the linear regime for which pulse pileup can be ignored. Results: The detector exhibited highly linear mean signal response across the system operating range and agreed well with theoretical prediction, as did the system MTF and NPS. The DQE analyzed as a function of kilovolt (peak), exposure, detector threshold, and readout mode revealed important considerations for system optimization. The model also demonstrated the important implications of false counts from both additive electronic noise and charge sharing and highlighted the system design and operational parameters that most affect detector performance in the presence of such factors: for example, increasing the detector threshold from 0 to 100 (arbitrary units of pulse height threshold roughly equivalent to 0.5 and 6 keV energy threshold, respectively), increased the f{sub 50} (spatial

  18. Track counting in radon dosimetry

    International Nuclear Information System (INIS)

    Fesenbeck, Ingo; Koehler, Bernd; Reichert, Klaus-Martin

    2013-01-01

    The newly developed, computer-controlled track counting system is capable of imaging and analyzing the entire area of nuclear track detectors. The high optical resolution allows a new analysis approach for the process of automated counting using digital image processing technologies. This way, higher exposed detectors can be evaluated reliably by an automated process as well. (orig.)

  19. An application of the coincidence Doppler spectroscopy for substances of chemical interest: phthalocyanine and acetylacetonate complexes

    International Nuclear Information System (INIS)

    Ito, Y.; Suzuki, T.

    2000-01-01

    Coincidence Doppler spectroscopy, which is particularly powerful when one is concerned with high momentum components of positron annihilation gamma-rays, has been applied to two different kinds of organo-metallic ligands: metal phthalocyanines and metal acetylacetonates. The energy (momentum) profiles of the annihilation gamma-rays were the same for metal phthalocyanines indicating that positron and/or positronium are not interacting with the metal ions. However, the profiles for the metal acetylacetonates evidently showed a dependence on the kind of metal ions. Discussion is made on the features of positron interaction which are different for phthalocyanines and acetylacetonates.

  20. Hall effects on unsteady MHD flow between two rotating disks with non-coincident parallel axes

    Energy Technology Data Exchange (ETDEWEB)

    Barik, R.N., E-mail: barik.rabinarayan@rediffmail.com [Department of Mathematics, Trident Academy of Technology, Bhubaneswar (India); Dash, G.C., E-mail: gcdash@indiatimes.com [Department of Mathematics, S.O.A. University, Bhubaneswar (India); Rath, P.K., E-mail: pkrath_1967@yahoo.in [Department of Mathematics, B.R.M. International Institute of Technology, Bhubaneswar (India)

    2013-01-15

    Hall effects on the unsteady MHD rotating flow of a viscous incompressible electrically conducting fluid between two rotating disks with non-coincident parallel axes have been studied. There exists an axisymmetric solution to this problem. The governing equations are solved by applying Laplace transform method. It is found that the torque experienced by the disks decreases with an increase in either the Hall parameter, m or the rotation parameter, S{sup 2}. Further, the axis of rotation has no effect on the fluid flow. (author)

  1. Hall effects on unsteady MHD flow between two rotating disks with non-coincident parallel axes

    International Nuclear Information System (INIS)

    Barik, R.N.; Dash, G.C.; Rath, P.K.

    2013-01-01

    Hall effects on the unsteady MHD rotating flow of a viscous incompressible electrically conducting fluid between two rotating disks with non-coincident parallel axes have been studied. There exists an axisymmetric solution to this problem. The governing equations are solved by applying Laplace transform method. It is found that the torque experienced by the disks decreases with an increase in either the Hall parameter, m or the rotation parameter, S 2 . Further, the axis of rotation has no effect on the fluid flow. (author)

  2. Simplified slow anti-coincidence circuit for Compton suppression systems

    International Nuclear Information System (INIS)

    Al-Azmi, Darwish

    2008-01-01

    Slow coincidence circuits for the anti-coincidence measurements have been considered for use in Compton suppression technique. The simplified version of the slow circuit has been found to be fast enough, satisfactory and allows an easy system setup, particularly with the advantage of the automatic threshold setting of the low-level discrimination. A well-type NaI detector as the main detector surrounded by plastic guard detector has been arranged to investigate the performance of the Compton suppression spectrometer using the simplified slow circuit. The system has been tested to observe the improvement in the energy spectra for medium to high-energy gamma-ray photons from terrestrial and environmental samples

  3. Device for multi-dimensional γ-γ-coincidence study

    International Nuclear Information System (INIS)

    Gruzinova, T.M.; Erokhina, K.I.; Kutuzov, V.I.; Lemberg, I.Kh.; Petrov, S.A.; Revenko, V.S.; Senin, A.T.; Chugunov, I.N.; Shishlinov, V.M.

    1977-01-01

    A device for studying multi-dimensional γ-γ coincidences is described which operates on-line with the BESM-4 computer. The device comprises Ge(Li) detectors, analog-to-digital converters, shaper discriminators and fast amplifiers. To control the device operation as a whole and to elaborate necessary commands, an information distributor has been developed. The following specific features of the device operation are noted: the device may operate both in the regime of recording spectra of direct γ radiation in the block memory of multi-channel analyzer, and in the regime of data transfer to the computer memory; the device performs registration of coincidences; it transfers information to the computer which has a channel of direct access to the memory. The procedure of data processing is considered, the data being recorded on a magnetic tape. Partial spectra obtained are in a good agreement with data obtained elsewhere

  4. Using CHIMERA detector at LNS for gamma-particle coincidences

    Directory of Open Access Journals (Sweden)

    Cardella G.

    2016-01-01

    Full Text Available We have recently evaluated the quality of γ-ray angular distributions that can be extracted in particle-gamma coincidence measurements using the CHIMERA detector at LNS. γ-rays have been detected using the CsI(Tl detectors of the spherical part of the CHIMERA array. Very clean γ-rays angular distributions were extracted in reactions induced by different stable beams impinging on 12C thin targets. The results evidenced an effect of projectile spin flip on the γ-rays angular distributions. γ-particle coincidence measurements were also performed in reactions induced by neutron rich exotic beams produced through in-flight fragmentation at LNS. In recent experiments also the Farcos array was used to improve energy and angular resolution measurements of the detected charged particles. Results obtained with both stable and radioactive beams are reported.

  5. Alpha-Photon Coincidence Spectroscopy Along Element 115 Decay Chains

    Energy Technology Data Exchange (ETDEWEB)

    Rudolph, D. [Lund Univ., Lund (Sweden); Forsberg, U. [Lund Univ., Lund (Sweden); Golubev, P. [Lund Univ., Lund (Sweden); Sarmiento, L. G. [Lund Univ., Lund (Sweden); Yakushev, A. [GSI Helmholtzzentrum fur Schwerionenforschung GmbH, Darmstadt (Germany); Andersson, L. -L. [Helmholtz Institute Mainz, Mainz (Germany); Di Nitto, A. [Johannes Gutenberg-Univ. Mainz, Mainz (Germany); Dullmann, Ch. E. [GSI Helmholtzzentrum fur Schwerionenforschung GmbH, Darmstadt (Germany); Helmholtz Institute Mainz, Mainz (Germany); Johannes Gutenberg-Univ. Mainz, Mainz (Germany); Gates, J. M. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Gregorich, K. E. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Gross, C. J. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Herzberg, R. -D. [Univ. of Liverpool, Liverpool (United Kingdom); Hessberger, F. P. [GSI Helmholtzzentrum fur Schwerionenforschung GmbH, Darmstadt (Germany); Helmholtz Institute Mainz, Mainz (Germany); Khuyagbaatar, J. [Helmholtz Institute Mainz, Mainz (Germany); Kratz, J. V. [Johannes Gutenberg-Univ. Mainz, Mainz (Germany); Rykaczewski, K. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Schadel, M. [GSI Helmholtzzentrum fur Schwerionenforschung GmbH, Darmstadt (Germany); Japan Atomic Energy Agency, Tokai (Japan); Aberg, S. [Lund Univ., Lund (Sweden); Ackermann, D. [GSI Helmholtzzentrum fur Schwerionenforschung GmbH, Darmstadt (Germany); Block, M. [GSI Helmholtzzentrum fur Schwerionenforschung GmbH, Darmstadt (Germany); Brand, H. [GSI Helmholtzzentrum fur Schwerionenforschung GmbH, Darmstadt (Germany); Carlsson, B. G. [Lund Univ., Lund (Sweden); Cox, D. [Univ. of Liverpool, Liverpool (United Kingdom); Derkx, X. [Helmholtz Institute Mainz, Mainz (Germany); Johannes Gutenberg-Univ. Mainz, Mainz (Germany); Eberhardt, K. [Helmholtz Institute Mainz, Mainz (Germany); Johannes Gutenberg-Univ. Mainz, Mainz (Germany); Even, J. [Helmholtz Institute Mainz, Mainz (Germany); Fahlander, C. [Lund Univ., Lund (Sweden); Gerl, J. [GSI Helmholtzzentrum fur Schwerionenforschung GmbH, Darmstadt (Germany); Jager, E. [GSI Helmholtzzentrum fur Schwerionenforschung GmbH, Darmstadt (Germany); Kindler, B. [GSI Helmholtzzentrum fur Schwerionenforschung GmbH, Darmstadt (Germany); Krier, J. [GSI Helmholtzzentrum fur Schwerionenforschung GmbH, Darmstadt (Germany); Kojouharov, I. [GSI Helmholtzzentrum fur Schwerionenforschung GmbH, Darmstadt (Germany); Kurz, N. [GSI Helmholtzzentrum fur Schwerionenforschung GmbH, Darmstadt (Germany); Lommel, B. [GSI Helmholtzzentrum fur Schwerionenforschung GmbH, Darmstadt (Germany); Mistry, A. [Univ. of Liverpool, Liverpool (United Kingdom); Mokry, C. [Helmholtz Institute Mainz, Mainz (Germany); Johannes Gutenberg-Univ. Mainz, Mainz (Germany); Nitsche, H. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Omtvedt, J. P. [Univ. of Oslo, Oslo (Norway); Papadakis, P. [Univ. of Liverpool, Liverpool (United Kingdom); Ragnarsson, I. [Lund Univ., Lund (Sweden); Runke, J. [GSI Helmholtzzentrum fur Schwerionenforschung GmbH, Darmstadt (Germany); Schaffner, H. [GSI Helmholtzzentrum fur Schwerionenforschung GmbH, Darmstadt (Germany); Schausten, B. [GSI Helmholtzzentrum fur Schwerionenforschung GmbH, Darmstadt (Germany); Thorle-Pospiech, P. [Helmholtz Institute Mainz, Mainz (Germany); Johannes Gutenberg-Univ. Mainz, Mainz (Germany); Torres, T. [GSI Helmholtzzentrum fur Schwerionenforschung GmbH, Darmstadt (Germany); Traut, T. [Johannes Gutenberg-Univ. Mainz, Mainz (Germany); Trautmann, N. [Johannes Gutenberg-Univ. Mainz, Mainz (Germany); Turler, A. [Paul Scherrer Institute and Univ. of Bern, Villigen (Switzerland); Ward, A. [Univ. of Liverpool, Liverpool (United Kingdom); Ward, D. E. [Lund Univ., Lund (Sweden); Wiehl, N. [Helmholtz Institute Mainz, Mainz (Germany); Johannes Gutenberg-Univ. Mainz, Mainz (Germany)

    2014-01-01

    Produced in the reaction 48Ca+ 243Am, thirty correlated α-decay chains were observed in an experiment conducted at the GSI Helmholzzentrum für Schwerionenforschung, Darmstadt, Germany. The decay chains are basically consistent with previous findings and are considered to originate from isotopes of element 115 with mass numbers 287, 288, and 289. A set-up aiming specifically for high-resolution charged particle and photon coincidence spectroscopy was placed behind the gas-filled separator TASCA. For the first time, γ rays as well as X-ray candidates were observed in prompt coincidence with the α-decay chains of element 115.

  6. Data Acquisition System for Electron Energy Loss Coincident Spectrometers

    International Nuclear Information System (INIS)

    Zhang Chi; Yu Xiaoqi; Yang Tao

    2005-01-01

    A Data Acquisition System (DAQ) for electron energy loss coincident spectrometers (EELCS) has been developed. The system is composed of a Multiplex Time-Digital Converter (TDC) that measures the flying time of positive and negative ions and a one-dimension position-sensitive detector that records the energy loss of scattering electrons. The experimental data are buffered in a first-in-first-out (FIFO) memory module, then transferred from the FIFO memory to PC by the USB interface. The DAQ system can record the flying time of several ions in one collision, and allows of different data collection modes. The system has been demonstrated at the Electron Energy Loss Coincident Spectrometers at the Laboratory of Atomic and Molecular Physics, USTC. A detail description of the whole system is given and experimental results shown

  7. Galaxy number counts: Pt. 2

    International Nuclear Information System (INIS)

    Metcalfe, N.; Shanks, T.; Fong, R.; Jones, L.R.

    1991-01-01

    Using the Prime Focus CCD Camera at the Isaac Newton Telescope we have determined the form of the B and R galaxy number-magnitude count relations in 12 independent fields for 21 m ccd m and 19 m ccd m 5. The average galaxy count relations lie in the middle of the wide range previously encompassed by photographic data. The field-to-field variation of the counts is small enough to define the faint (B m 5) galaxy count to ±10 per cent and this variation is consistent with that expected from galaxy clustering considerations. Our new data confirm that the B, and also the R, galaxy counts show evidence for strong galaxy luminosity evolution, and that the majority of the evolving galaxies are of moderately blue colour. (author)

  8. Hanford whole body counting manual

    International Nuclear Information System (INIS)

    Palmer, H.E.; Brim, C.P.; Rieksts, G.A.; Rhoads, M.C.

    1987-05-01

    This document, a reprint of the Whole Body Counting Manual, was compiled to train personnel, document operation procedures, and outline quality assurance procedures. The current manual contains information on: the location, availability, and scope of services of Hanford's whole body counting facilities; the administrative aspect of the whole body counting operation; Hanford's whole body counting facilities; the step-by-step procedure involved in the different types of in vivo measurements; the detectors, preamplifiers and amplifiers, and spectroscopy equipment; the quality assurance aspect of equipment calibration and recordkeeping; data processing, record storage, results verification, report preparation, count summaries, and unit cost accounting; and the topics of minimum detectable amount and measurement accuracy and precision. 12 refs., 13 tabs

  9. High-level neutron coincidence counter (HLNCC): users' manual

    International Nuclear Information System (INIS)

    Krick, M.S.; Menlove, H.O.

    1979-06-01

    This manual describes the portable High-Level Neutron Coincidence Counter (HLNCC) developed at the Los Alamos Scientific Laboratory (LASL) for the assay of plutonium, particularly by inspectors of the International Atomic Energy Agency (IAEA). The counter is designed for the measurement of the effective 240 Pu mass in plutonium samples which may have a high plutonium content. The following topics are discussed: principle of operation, description of the system, operating procedures, and applications

  10. Coincidence of asthma and bronchospasm during anesthesia in tympanomastoidectomy.

    OpenAIRE

    Nima Hosseinzadeh; Shahram Samadi; Amin Amali; Mihan Jafari Javid

    2014-01-01

    High prevalence of asthma and bronchospasm was observed during induction of anesthesia in patients with chronic suppurative otitis mMedia (CSOM) who underwent tympanomastoidectomy. Although several studies have proposed association of allergic diseases with CSOM but no consensus about it has been established. Current study was designed to determine the coincidence of asthma in CSOM patients. In a cross-sectional study, authors investigated medical records of 106 CSOM patients underwent tympan...

  11. Energy and depth resolution in elastic recoil coincidence spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Szilagyi, E., E-mail: szilagyi@rmki.kfki.h [KFKI Research Institute for Particle and Nuclear Physics, P.O. Box 49, H-1525 Budapest (Hungary)

    2010-06-15

    Elastic recoil coincidence spectrometry was implemented into the analytical ion beam simulation program DEPTH. In the calculations, effective detector geometry and multiple scattering effects are considered. Mott's cross section for the identical, spin zero particles is included. Spectra based on the individual detector signal and summing the energy of the recoiled and scattered particles originating from the same scattering events can also be calculated. To calculate this latter case, the dependency of the energy spread contributions had to be reconsidered.

  12. Energy and depth resolution in elastic recoil coincidence spectrometry

    International Nuclear Information System (INIS)

    Szilagyi, E.

    2010-01-01

    Elastic recoil coincidence spectrometry was implemented into the analytical ion beam simulation program DEPTH. In the calculations, effective detector geometry and multiple scattering effects are considered. Mott's cross section for the identical, spin zero particles is included. Spectra based on the individual detector signal and summing the energy of the recoiled and scattered particles originating from the same scattering events can also be calculated. To calculate this latter case, the dependency of the energy spread contributions had to be reconsidered.

  13. X-ray line coincidence photopumping in a solar flare

    Science.gov (United States)

    Keenan, F. P.; Poppenhaeger, K.; Mathioudakis, M.; Rose, S. J.; Flowerdew, J.; Hynes, D.; Christian, D. J.; Nilsen, J.; Johnson, W. R.

    2018-03-01

    Line coincidence photopumping is a process where the electrons of an atomic or molecular species are radiatively excited through the absorption of line emission from another species at a coincident wavelength. There are many instances of line coincidence photopumping in astrophysical sources at optical and ultraviolet wavelengths, with the most famous example being Bowen fluorescence (pumping of O III 303.80 Å by He II), but none to our knowledge in X-rays. However, here we report on a scheme where a He-like line of Ne IX at 11.000 Å is photopumped by He-like Na X at 11.003 Å, which predicts significant intensity enhancement in the Ne IX 82.76 Å transition under physical conditions found in solar flare plasmas. A comparison of our theoretical models with published X-ray observations of a solar flare obtained during a rocket flight provides evidence for line enhancement, with the measured degree of enhancement being consistent with that expected from theory, a truly surprising result. Observations of this enhancement during flares on stars other than the Sun would provide a powerful new diagnostic tool for determining the sizes of flare loops in these distant, spatially unresolved, astronomical sources.

  14. Post training REMs coincident auditory stimulation enhances memory in humans.

    Science.gov (United States)

    Smith, C; Weeden, K

    1990-06-01

    Sleep activity was monitored in 20 freshman college students for two consecutive nights. Subjects were assigned to 4 equal groups and all were asked to learn a complex logic task before bed on the second night. Two groups of subjects learned the task with a constant clicking noise in the background (cued groups), while two groups simply learned the task (non cued). During the night, one cued and one non cued group were presented with auditory clicks during REM sleep such as to coincide with all REMs of at least 100 microvolts. The second cued group was given auditory clicks during REM sleep, but only during the REMs "quiet" times. The second non-cued control group was never given any nighttime auditory stimulations. The cued REMs coincident group showed a significant 23% improvement in task performance when tested one week later. The non cued REMs coincident group showed only an 8.8% improvement which was not significant. The cued REMs quiet and non-stimulated control groups showed no change in task performance when retested. The results were interpreted as support for the idea that the cued auditory stimulation induced a "recall" of the learned material during the REM sleep state in order for further memory processing to take place.

  15. Imaging photoelectron circular dichroism of chiral molecules by femtosecond multiphoton coincidence detection

    Energy Technology Data Exchange (ETDEWEB)

    Lehmann, C. Stefan; Ram, N. Bhargava; Janssen, Maurice H. M., E-mail: m.h.m.janssen@vu.nl [LaserLaB Amsterdam, VU University Amsterdam, De Boelelaan 1081, 1081 HV Amsterdam (Netherlands); Powis, Ivan [School of Chemistry, University of Nottingham, Nottingham NG7 2RD (United Kingdom)

    2013-12-21

    Here, we provide a detailed account of novel experiments employing electron-ion coincidence imaging to discriminate chiral molecules. The full three-dimensional angular scattering distribution of electrons is measured after photoexcitation with either left or right circular polarized light. The experiment is performed using a simplified photoelectron-photoion coincidence imaging setup employing only a single particle imaging detector. Results are reported applying this technique to enantiomers of the chiral molecule camphor after three-photon ionization by circularly polarized femtosecond laser pulses at 400 nm and 380 nm. The electron-ion coincidence imaging provides the photoelectron spectrum of mass-selected ions that are observed in the time-of-flight mass spectra. The coincident photoelectron spectra of the parent camphor ion and the various fragment ions are the same, so it can be concluded that fragmentation of camphor happens after ionization. We discuss the forward-backward asymmetry in the photoelectron angular distribution which is expressed in Legendre polynomials with moments up to order six. Furthermore, we present a method, similar to one-photon electron circular dichroism, to quantify the strength of the chiral electron asymmetry in a single parameter. The circular dichroism in the photoelectron angular distribution of camphor is measured to be 8% at 400 nm. The electron circular dichroism using femtosecond multiphoton excitation is of opposite sign and about 60% larger than the electron dichroism observed before in near-threshold one-photon ionization with synchrotron excitation. We interpret our multiphoton ionization as being resonant at the two-photon level with the 3s and 3p Rydberg states of camphor. Theoretical calculations are presented that model the photoelectron angular distribution from a prealigned camphor molecule using density functional theory and continuum multiple scattering X alpha photoelectron scattering calculations

  16. Use of pliable bags in liquid scintillation counting

    International Nuclear Information System (INIS)

    Simonnet, G.; Jacquet, M.A.; Sharif, A.; Engler, R.

    1981-01-01

    Pliable plastic bags have been used to replace glass or plastic vials for liquid scintillation counting. The two major advantages of this method are the lower cost of the plastic bags and the fact that, per sample, the radioactive waste is significantly reduced. The following parameters have been checked: the impermeability of the bags to various scintillator mixtures and the fact that neither the irregular shape of the bags nor their position in the counting chamber had any effect on the results of the counting. The latter was also constant with time, at least over a period of 10 days. The technique has been used to count the radioactivity of 3 H-DNA precipitates prepared from bacteria and lymphocytes and deposited on filters impregnated with only 200 μl scintillator. It is a method that can be applied to the counting of any samples deposited on filters and insoluble in scintillator. (author)

  17. Real-Time, Fast Neutron Coincidence Assay of Plutonium With a 4-Channel Multiplexed Analyzer and Organic Scintillators

    Science.gov (United States)

    Joyce, Malcolm J.; Gamage, Kelum A. A.; Aspinall, M. D.; Cave, F. D.; Lavietes, A.

    2014-06-01

    The design, principle of operation and the results of measurements made with a four-channel organic scintillator system are described. The system comprises four detectors and a multiplexed analyzer for the real-time parallel processing of fast neutron events. The function of the real-time, digital multiple-channel pulse-shape discrimination analyzer is described together with the results of laboratory-based measurements with 252Cf, 241Am-Li and plutonium. The analyzer is based on a single-board solution with integrated high-voltage supplies and graphical user interface. It has been developed to meet the requirements of nuclear materials assay of relevance to safeguards and security. Data are presented for the real-time coincidence assay of plutonium in terms of doubles count rate versus mass. This includes an assessment of the limiting mass uncertainty for coincidence assay based on a 100 s measurement period and samples in the range 0-50 g. Measurements of count rate versus order of multiplicity for 252Cf and 241Am-Li and combinations of both are also presented.

  18. In vivo counting of uranium

    International Nuclear Information System (INIS)

    Palmer, H.E.

    1985-03-01

    A state-of-the-art radiation detector system consisting of six individually mounted intrinsic germanium planar detectors, each 20 cm 2 by 13 mm thick, mounted together such that the angle of the whole system can be changed to match the slope of the chest of the person being counted, is described. The sensitivity of the system for counting uranium and plutonium in vivo and the precedures used in calibrating the system are also described. Some results of counts done on uranium mill workers are presented. 15 figs., 2 tabs

  19. Poissonian and binomial models in radionuclide metrology by liquid scintillation counting

    International Nuclear Information System (INIS)

    Grau Malonda, A.

    1990-01-01

    Binomial and Poissonian models developed for calculating the counting efficiency from a free parameter is analysed in this paper. This model have been applied to liquid scintillator counting systems with two or three photomultipliers. It is mathematically demostrated that both models are equivalent and that the counting efficiencies calculated either from one or the other model are identical. (Author)

  20. Radon Daughters Background Reduction in Alpha Particles Counting System

    International Nuclear Information System (INIS)

    Dadon, S. S.; Pelled, O.; Orion, I.

    2014-01-01

    The ABPC method is using a serially occurring events of the beta decay of the 214Bi fallow by alpha decay of the 214Po that take place almost simultaneously to detect the Pseudo Coincidence Event (PCE) from the RDP, and to subtract them from the gross alpha counts. 267 This work showed that it is possible to improve the efficiency of RDP background reduction, including subtracting the 218Po contribution by using the ABPC method based on a single solid state silicon PIPS detector. False counts percentage obtained at the output of the PCE circuit were smaller than 0.1%. The results show that the PCE circuit was not influenced by non RDP alpha emitters. The PCE system did not reduce the non PCE of the 218Po. After 20 minutes the 218Po was strongly decayed, and its contribution became negligible. In order to overcome this disadvantage, a mathematical matching calculations for the 214Po and the 218Po decay equations were employed, and a constant ratio of the APo214(0) / APo218(0) was obtained. This ratio can be used to estimate the count rate of the 218Po at the first 20 minutes, and to subtract it from the total count rate in order to obtain correct RDP reduction

  1. Suitability study of using a coincidence monitor for room air radioactivity monitoring in a PET center

    International Nuclear Information System (INIS)

    Roellig, D.; Reichelt, C.; Iwatschenko-Borho, M.

    2001-01-01

    The application of radioactive nuclides in medicine may cause as well radioactive exposure of personnel (Medical Technical Assistants). In the present case the exposure of personnel in the area of medical positron-emission tomography (PET) within the Research Center of Rossendorf due to exhalation of the injected activity by the patient shall be investigated. For this purpose it is necessary to measure the activity concentration of the room air. Conventional methods such as collecting samples on special filters are not suitable due to the short half-life time of the used nuclides. Standard type continuous monitors are hardly suitable as well, because the injected activity of the patient and various radioactive sources required for the calibration of the PET-Camera produce an increased gamma background. In order to eliminate these disturbing influences a monitor has been constructed which uses CCM (cobalt coincidence method) developed by the company Thermo Eberline ESM. This method is specially suitable because upon each radioactive decay of PET nuclides positrons are emitted which in turn annihilate via the simultaneous emission of two 511 keV gamma quanta under an angle of 180 . The air to be measured is sucked through a cavity with two scintillation detectors on opposite sides. The coincident pulses produced by annihilating positrons inside the cavity are counted by a suitable electronic. Gamma quanta from outside the cavity can produce a pulse only in one detector and are rejected. Therefore no heavy lead shielding is required. Besides the mechanical construction of the monitor optimization and calibration for different PET-nuclides had to be performed. Special attention was paid to the sampling system. The air intake had to be close to the breathing zone of the MTA. The hose to the monitor had to be as short as possible. The target of the work was to design a model for an industrial monitor. (orig.) [de

  2. Monte Carlo simulation of {beta}-{gamma} coincidence system using plastic scintillators in 4{pi} geometry

    Energy Technology Data Exchange (ETDEWEB)

    Dias, M.S. [Instituto de Pesquisas Energeticas e Nucleares: IPEN-CNEN/SP, Av. Prof. Lineu Prestes 2242, 05508-000 Sao Paulo, SP (Brazil)], E-mail: msdias@ipen.br; Piuvezam-Filho, H. [Instituto de Pesquisas Energeticas e Nucleares: IPEN-CNEN/SP, Av. Prof. Lineu Prestes 2242, 05508-000 Sao Paulo, SP (Brazil); Baccarelli, A.M. [Departamento de Fisica-PUC/SP-Rua Marques de Paranagua 111, 01303-050 Sao Paulo, SP (Brazil); Takeda, M.N. [Universidade Santo Amaro, UNISA-Rua Prof. Eneas da Siqueira Neto 340, 04829-300 Sao Paulo, SP (Brazil); Koskinas, M.F. [Instituto de Pesquisas Energeticas e Nucleares: IPEN-CNEN/SP, Av. Prof. Lineu Prestes 2242, 05508-000 Sao Paulo, SP (Brazil)

    2007-09-21

    A modified version of a Monte Carlo code called Esquema, developed at the Nuclear Metrology Laboratory in IPEN, Sao Paulo, Brazil, has been applied for simulating a 4{pi}{beta}(PS)-{gamma} coincidence system designed for primary radionuclide standardisation. This system consists of a plastic scintillator in 4{pi} geometry, for alpha or electron detection, coupled to a NaI(Tl) counter for gamma-ray detection. The response curves for monoenergetic electrons and photons have been calculated previously by Penelope code and applied as input data to code Esquema. The latter code simulates all the disintegration processes, from the precursor nucleus to the ground state of the daughter radionuclide. As a result, the curve between the observed disintegration rate as a function of the beta efficiency parameter can be simulated. A least-squares fit between the experimental activity values and the Monte Carlo calculation provided the actual radioactive source activity, without need of conventional extrapolation procedures. Application of this methodology to {sup 60}Co and {sup 133}Ba radioactive sources is presented and showed results in good agreement with a conventional proportional counter 4{pi}{beta}(PC)-{gamma} coincidence system.

  3. Monte Carlo simulation of β-γ coincidence system using plastic scintillators in 4π geometry

    International Nuclear Information System (INIS)

    Dias, M.S.; Piuvezam-Filho, H.; Baccarelli, A.M.; Takeda, M.N.; Koskinas, M.F.

    2007-01-01

    A modified version of a Monte Carlo code called Esquema, developed at the Nuclear Metrology Laboratory in IPEN, Sao Paulo, Brazil, has been applied for simulating a 4πβ(PS)-γ coincidence system designed for primary radionuclide standardisation. This system consists of a plastic scintillator in 4π geometry, for alpha or electron detection, coupled to a NaI(Tl) counter for gamma-ray detection. The response curves for monoenergetic electrons and photons have been calculated previously by Penelope code and applied as input data to code Esquema. The latter code simulates all the disintegration processes, from the precursor nucleus to the ground state of the daughter radionuclide. As a result, the curve between the observed disintegration rate as a function of the beta efficiency parameter can be simulated. A least-squares fit between the experimental activity values and the Monte Carlo calculation provided the actual radioactive source activity, without need of conventional extrapolation procedures. Application of this methodology to 60 Co and 133 Ba radioactive sources is presented and showed results in good agreement with a conventional proportional counter 4πβ(PC)-γ coincidence system

  4. Complete Blood Count (For Parents)

    Science.gov (United States)

    ... Kids Deal With Injections and Blood Tests Blood Culture Anemia Blood Test: Basic Metabolic Panel (BMP) Blood Test: Hemoglobin Basic Blood Chemistry Tests Word! Complete Blood Count (CBC) Medical Tests and Procedures ( ...

  5. Make My Trip Count 2015

    Data.gov (United States)

    Allegheny County / City of Pittsburgh / Western PA Regional Data Center — The Make My Trip Count (MMTC) commuter survey, conducted in September and October 2015 by GBA, the Pittsburgh 2030 District, and 10 other regional transportation...

  6. Counting Triangles to Sum Squares

    Science.gov (United States)

    DeMaio, Joe

    2012-01-01

    Counting complete subgraphs of three vertices in complete graphs, yields combinatorial arguments for identities for sums of squares of integers, odd integers, even integers and sums of the triangular numbers.

  7. Counting the clouds

    International Nuclear Information System (INIS)

    Randall, David A

    2005-01-01

    Cloud processes are very important for the global circulation of the atmosphere. It is now possible, though very expensive, to simulate the global circulation of the atmosphere using a model with resolution fine enough to explicitly represent the larger individual clouds. An impressive preliminary calculation of this type has already been performed by Japanese scientists, using the Earth Simulator. Within the next few years, such global cloud-resolving models (GCRMs) will be applied to weather prediction, and later they will be used in climatechange simulations. The tremendous advantage of GCRMs, relative to conventional lowerresolution global models, is that GCRMs can avoid many of the questionable 'parameterizations' used to represent cloud effects in lower-resolution global models. Although cloud microphysics, turbulence, and radiation must still be parameterized in GCRMs, the high resolution of a GCRM simplifies these problems considerably, relative to conventional models. The United States currently has no project to develop a GCRM, although we have both the computer power and the expertise to do it. A research program aimed at development and applications of GCRMs is outlined

  8. Counting Word Frequencies with Python

    Directory of Open Access Journals (Sweden)

    William J. Turkel

    2012-07-01

    Full Text Available Your list is now clean enough that you can begin analyzing its contents in meaningful ways. Counting the frequency of specific words in the list can provide illustrative data. Python has an easy way to count frequencies, but it requires the use of a new type of variable: the dictionary. Before you begin working with a dictionary, consider the processes used to calculate frequencies in a list.

  9. Liquid scintillation counting of chlorophyll

    International Nuclear Information System (INIS)

    Fric, F.; Horickova, B.; Haspel-Horvatovic, E.

    1975-01-01

    A precise and reproducible method of liquid scintillation counting was worked out for measuring the radioactivity of 14 C-labelled chlorophyll a and chlorophyll b solutions without previous bleaching. The spurious count rate caused by luminescence of the scintillant-chlorophyll system is eliminated by using a suitable scintillant and by measuring the radioactivity at 4 to 8 0 C after an appropriate time of dark adaptation. Bleaching of the chlorophyll solutions is necessary only for measuring of very low radioactivity. (author)

  10. Coincident brane nucleation and the neutralization of Λ

    International Nuclear Information System (INIS)

    Garriga, Jaume; Megevand, Ariel

    2004-01-01

    Nucleation of branes by a four-form field has recently been considered in string motivated scenarios for the neutralization of the cosmological constant. An interesting question in this context is whether the nucleation of stacks of coincident branes is possible, and if so, at what rate does it proceed. Feng et al. have suggested that, at high ambient de Sitter temperature, the rate may be strongly enhanced, due to large degeneracy factors associated with the number of light species living on the worldsheet. This might facilitate the quick relaxation from a large effective cosmological constant down to the observed value. Here, we analyze this possibility in some detail. In four dimensions, and after the moduli are stabilized, branes interact via repulsive long range forces. Because of that, the Coleman-de Luccia (CdL) instanton for coincident brane nucleation may not exist, unless there is some short range interaction that keeps the branes together. If the CdL instanton exists, we find that the degeneracy factor depends only mildly on the ambient de Sitter temperature, and does not switch off even in the case of tunneling from flat space. This would result in catastrophic decay of the present vacuum. If, on the contrary, the CdL instanton does not exist, coincident brane nucleation may still proceed through a 'static' instanton, representing pair creation of critical bubbles--a process somewhat analogous to thermal activation in flat space. In that case, the branes may stick together due to thermal symmetry restoration, and the pair creation rate depends exponentially on the ambient de Sitter temperature, switching off sharply as the temperature approaches zero. Such a static instanton may be well suited for the 'saltatory' relaxation scenario proposed by Feng et al

  11. Improving Quality Of Spectrum Measurement By Event - Event Coincidence Technique

    International Nuclear Information System (INIS)

    Pham Dinh Khang; Doan Trong Thu; Nguyen Duc Hoa; Nguyen An Son; Nguyen Xuan Hai; Ho Huu Thang

    2011-01-01

    To improve the quality of measurement data for the research levels density and gamma strength function in intermediate energy region below the neutron binding energy (B n ), a new method was developed at the Dalat Nuclear Research Institute. This method improve the ratio of the count of peak per compton background more times. This results are evaluated, compared with other methods. (author)

  12. Bell's inequalities and the four-coincidence experiment

    International Nuclear Information System (INIS)

    Garuccio, A.; Rapisarda, V.A.

    1981-01-01

    The four-coincidence experiment, in which two correlated particles interact, each, with a dichotomic-detection apparatus, is formally described. Some care is devoted to analyze what is due to the structure of the experiment, and what can really be measured. Some of the questions which the experiment can answer are posed in a general probabilistic hidden-variable frame and, for the QM point of view, in the specific case of the 0-1-0 calcium atomic cascade. Besides, a new method to treat discriminating inequalities is shown which allows, in our opinion, a deeper insight into the theoretical assumptions together with a better experimental reliability. (author)

  13. Reconstructed Image Spatial Resolution of Multiple Coincidences Compton Imager

    Science.gov (United States)

    Andreyev, Andriy; Sitek, Arkadiusz; Celler, Anna

    2010-02-01

    We study the multiple coincidences Compton imager (MCCI) which is based on a simultaneous acquisition of several photons emitted in cascade from a single nuclear decay. Theoretically, this technique should provide a major improvement in localization of a single radioactive source as compared to a standard Compton camera. In this work, we investigated the performance and limitations of MCCI using Monte Carlo computer simulations. Spatial resolutions of the reconstructed point source have been studied as a function of the MCCI parameters, including geometrical dimensions and detector characteristics such as materials, energy and spatial resolutions.

  14. High-level neutron coincidence counter maintenance manual

    International Nuclear Information System (INIS)

    Swansen, J.; Collinsworth, P.

    1983-05-01

    High-level neutron coincidence counter operational (field) calibration and usage is well known. This manual makes explicit basic (shop) check-out, calibration, and testing of new units and is a guide for repair of failed in-service units. Operational criteria for the major electronic functions are detailed, as are adjustments and calibration procedures, and recurrent mechanical/electromechanical problems are addressed. Some system tests are included for quality assurance. Data on nonstandard large-scale integrated (circuit) components and a schematic set are also included

  15. Coincident systemic lupus erythematosus and psoriasis vulgaris: a case report.

    Science.gov (United States)

    Wang, Y; Da, G; Yu, Y; Han, J; Li, H

    2015-12-01

    Psoriasis vulgaris is an autoimmune chronic inflammatory skin disease, but its association with other typical autoimmune disease such as systemic lupus erythematosus has only occasionally been reported. We presented a 25-year-old female who developed systemic lupus erythematosus associated with psoriasis vulgaris. Her conditions were in good control after she got administration of prednisolone (5 mg/day) and Tripterygium Wilfordii Hook (20 mg/day). It is necessary to integrate past history and physical examination to diagnose coincident SLE and psoriasis, and combined treatment with prednisolone and Tripterygium Wilfordii Hook proves effective.

  16. Coincidence corrected efficiency calibration of Compton-suppressed HPGe detectors

    Energy Technology Data Exchange (ETDEWEB)

    Aucott, Timothy [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Brand, Alexander [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); DiPrete, David [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2015-04-20

    The authors present a reliable method to calibrate the full-energy efficiency and the coincidence correction factors using a commonly-available mixed source gamma standard. This is accomplished by measuring the peak areas from both summing and non-summing decay schemes and simultaneously fitting both the full-energy efficiency, as well as the total efficiency, as functions of energy. By using known decay schemes, these functions can then be used to provide correction factors for other nuclides not included in the calibration standard.

  17. High-level neutron coincidence counter maintenance manual

    Energy Technology Data Exchange (ETDEWEB)

    Swansen, J.; Collinsworth, P.

    1983-05-01

    High-level neutron coincidence counter operational (field) calibration and usage is well known. This manual makes explicit basic (shop) check-out, calibration, and testing of new units and is a guide for repair of failed in-service units. Operational criteria for the major electronic functions are detailed, as are adjustments and calibration procedures, and recurrent mechanical/electromechanical problems are addressed. Some system tests are included for quality assurance. Data on nonstandard large-scale integrated (circuit) components and a schematic set are also included.

  18. Preliminary results of a neutron-gamma coincidence experiment

    International Nuclear Information System (INIS)

    Piercey, R.B.; Dunnam, F.E.; Muga, M.L.; Rester, A.C.; Ramayya, A.V.; Hamilton, J.H.; Eberth, J.; Zganjar, E.F.

    1984-01-01

    The recently completed neutron multiplicity detector dubbed PANDA (Pentagonal Annular Neutron Detector Array) is fully described later in this report. The new detector was recently used for the first time on-line at the Holifield Heavy Ion Research Facility to measure neutron-gamma coincidence in the 24 Mg( 58 Ni,xαypzn) reaction. The detector configuration for the experiment is shown. The PANDA was situated in the forward direction, coaxial to the beam line with five gamma-ray detectors placed at +/- 90 0 , +/- 135 0 , and 0 0 . 2 figures

  19. Count-rate analysis from clinical scans in PET with LSO detectors

    International Nuclear Information System (INIS)

    Bonutti, F.; Cattaruzzi, E.; Cragnolini, E.; Floreani, M.; Foti, C.; Malisan, M. R.; Moretti, E.; Geatti, O.; Padovani, R.

    2008-01-01

    The purpose of optimising the acquisition parameters in positron emission tomography is to improve the quality of the diagnostic images. Optimisation can be done by maximising the noise equivalent count rate (NECR) that in turn depends on the coincidence rate. For each bed position the scanner records coincidences and singles rates. For each patient, the true, random and scattered coincidences as functions of the single count rate(s) are determined by fitting the NEMA (National Electrical Manufacturers Association) 70 cm phantom count rate curves to measured clinical points. This enables analytical calculation of the personalised PNECR [pseudo NECR(s)] curve, linked to the NECR curve. For central bed positions, missing activity of ∼70% is estimated to get maximum PNECR (PNECR max ), but the improvement in terms of signal-to-noise ratio would be ∼15%. The correlation between patient weight and PNECR max is also estimated to determine the optimal scan duration of a single bed position as a function of patient weight at the same PNEC. Normalising the counts at PNECR max for the 70 kg patient, the bed duration for a 90 kg patient should be 230 s, which is ∼30% longer. Although the analysis indicates that the fast scanner electronics allow using higher administered activities, this would involve poor improvement in terms of NECR. Instead, attending to higher bed duration for heavier patients may be more useful. (authors)

  20. Evaluation of Deterministic and Stochastic Components of Traffic Counts

    Directory of Open Access Journals (Sweden)

    Ivan Bošnjak

    2012-10-01

    Full Text Available Traffic counts or statistical evidence of the traffic processare often a characteristic of time-series data. In this paper fundamentalproblem of estimating deterministic and stochasticcomponents of a traffic process are considered, in the context of"generalised traffic modelling". Different methods for identificationand/or elimination of the trend and seasonal componentsare applied for concrete traffic counts. Further investigationsand applications of ARIMA models, Hilbert space formulationsand state-space representations are suggested.

  1. Coincidence measurements with the use of detectors measuring the energy of the radiances (proportional meters and scintillation counter); Mesures de coincidences avec utilisation de detecteurs mesurant l'energie des rayonnements (compteurs proportionnels et compteur a scintillations)

    Energy Technology Data Exchange (ETDEWEB)

    Sartory, M [Commissariat a l' Energie Atomique, Saclay(France). Centre d' Etudes Nucleaires

    1953-07-01

    In the setting of the realization of a set of installations permitting of the measures of coincidences between sorted radiances according to their energies, an installation understanding a proportional counter and a scintillation counter has been constructed and optimized. It has been used to do some measures of coincidences between X{sub K} photons and photons {gamma} issued at the time of the radioactive transformation of the selenium 75 (electronic capture). The efficiency of the proportional meter has been determined roughly. Besides, a proportional counter of solid angle neighboring of 4{pi} was able to achieve measures of coincidences while only doing one selection of amplitudes: indeed, the simultaneity of the detection of two radiances appear by an impulse whose amplitude is the sum of the amplitudes of the impulses resulting from each of the studied radiations. This method, applied to the coincidences between X-rays, permitted to bring the information on the diagram of decay of the arsenic 73. Besides, the coefficient of internal conversion of a consecutive transition to this decay has been valued. (author) [French] Dans le cadre de la realisation d'une serie de montages permettant des mesures de coincidences entre rayonnements tries d'apres leurs energies, un montage comprenant un compteur proportionnel et un compteur a scintillations a ete construit et mis au point. Il a ete utilise pour effectuer quelques mesures de coincidences entre photons X{sub K} et photons {gamma} emis lors de la transformation radioactive du selenium 75 (capture electronique). L'efficacite du compteur proportionnel a ete approximativement determinee. De plus, un compteur proportionnel d'angle solide voisin de 4{pi} a pu etre utilise pour realiser des mesures de coincidences en n'effectuant qu'une selection d'amplitudes: en effet, la simultaneite de la detection de deux rayonnements se manifeste par une impulsion dont l'amplitude est la somme des amplitudes des impulsions

  2. Coincidence of lung cancer and silicosis in Czechoslovak uranium miners

    International Nuclear Information System (INIS)

    Urban, S.; Urbanova, S.

    1988-01-01

    27 patients with established coincidence of lung cancer and silicosis from a group of 1607 cases of lung cancer from radioactive compounds, and 166 cases of pneumoconiosis were reported by the Occupational Diseases Ward of the works Institute of National Health in Uranium Industry in the 1962 to 1986 years. Lung cancer was found in 16% of reported silicosis patients, in 81% it was simple silicosis, in 50% of cases in was an epidermoid type of cancer. In two cases the malignant process originated in the silicotic node, in one case from a tuberculoma. Lung cancer occurred most frequently in the right lower lung region. The mean age of the silicosis group was 48.6 years and 56.0 years for the lung cancer group. No difference was thus seen from the mean age of patients with lung cancer from radioactive compounds diagnosed in the years 1976 to 1980 but it was significantly lower that the reported average age of patients with coincidence of lung cancer and pneumoconiosis in the population not exposed to ionizing radiation. (author). 2 figs., 1 tab., 18 refs

  3. Coincidence Detection Using Spiking Neurons with Application to Face Recognition

    Directory of Open Access Journals (Sweden)

    Fadhlan Kamaruzaman

    2015-01-01

    Full Text Available We elucidate the practical implementation of Spiking Neural Network (SNN as local ensembles of classifiers. Synaptic time constant τs is used as learning parameter in representing the variations learned from a set of training data at classifier level. This classifier uses coincidence detection (CD strategy trained in supervised manner using a novel supervised learning method called τs Prediction which adjusts the precise timing of output spikes towards the desired spike timing through iterative adaptation of τs. This paper also discusses the approximation of spike timing in Spike Response Model (SRM for the purpose of coincidence detection. This process significantly speeds up the whole process of learning and classification. Performance evaluations with face datasets such as AR, FERET, JAFFE, and CK+ datasets show that the proposed method delivers better face classification performance than the network trained with Supervised Synaptic-Time Dependent Plasticity (STDP. We also found that the proposed method delivers better classification accuracy than k nearest neighbor, ensembles of kNN, and Support Vector Machines. Evaluation on several types of spike codings also reveals that latency coding delivers the best result for face classification as well as for classification of other multivariate datasets.

  4. Cochlear spike synchronization and neuron coincidence detection model

    Science.gov (United States)

    Bader, Rolf

    2018-02-01

    Coincidence detection of a spike pattern fed from the cochlea into a single neuron is investigated using a physical Finite-Difference model of the cochlea and a physiologically motivated neuron model. Previous studies have shown experimental evidence of increased spike synchronization in the nucleus cochlearis and the trapezoid body [Joris et al., J. Neurophysiol. 71(3), 1022-1036 and 1037-1051 (1994)] and models show tone partial phase synchronization at the transition from mechanical waves on the basilar membrane into spike patterns [Ch. F. Babbs, J. Biophys. 2011, 435135]. Still the traveling speed of waves on the basilar membrane cause a frequency-dependent time delay of simultaneously incoming sound wavefronts up to 10 ms. The present model shows nearly perfect synchronization of multiple spike inputs as neuron outputs with interspike intervals (ISI) at the periodicity of the incoming sound for frequencies from about 30 to 300 Hz for two different amounts of afferent nerve fiber neuron inputs. Coincidence detection serves here as a fusion of multiple inputs into one single event enhancing pitch periodicity detection for low frequencies, impulse detection, or increased sound or speech intelligibility due to dereverberation.

  5. Coincidence-anticipation timing requirements are different in racket sports.

    Science.gov (United States)

    Akpinar, Selçuk; Devrilmez, Erhan; Kirazci, Sadettin

    2012-10-01

    The aim of this study was to compare the coincidence-anticipation timing accuracy of athletes of different racket sports with various stimulus velocity requirements. Ninety players (15 girls, 15 boys for each sport) from tennis (M age = 12.4 yr., SD = 1.4), badminton (M age = 12.5 yr., SD = 1.4), and table tennis (M age = 12.4 yr., SD = 1.2) participated in this study. Three different stimulus velocities, low, moderate, and high, were used to simulate the velocity requirements of these racket sports. Tennis players had higher accuracy when they performed under the low stimulus velocity compared to badminton and table tennis players. Badminton players performed better under the moderate speed comparing to tennis and table tennis players. Table tennis players had better performance than tennis and badminton players under the high stimulus velocity. Therefore, visual and motor systems of players from different racket sports may adapt to a stimulus velocity in coincidence-anticipation timing, which is specific to each type of racket sports.

  6. Imaging photoelectron photoion coincidence spectroscopy with velocity focusing electron optics

    International Nuclear Information System (INIS)

    Bodi, Andras; Johnson, Melanie; Gerber, Thomas; Gengeliczki, Zsolt; Sztaray, Balint; Baer, Tomas

    2009-01-01

    An imaging photoelectron photoion coincidence spectrometer at the vacuum ultraviolet (VUV) beamline of the Swiss Light Source is presented and a few initial measurements are reported. Monochromatic synchrotron VUV radiation ionizes the cooled or thermal gas-phase sample. Photoelectrons are velocity focused, with better than 1 meV resolution for threshold electrons, and also act as start signal for the ion time-of-flight analysis. The ions are accelerated in a relatively low, 40-80 V cm -1 field, which enables the direct measurement of rate constants in the 10 3 -10 7 s -1 range. All electron and ion events are recorded in a triggerless multiple-start/multiple-stop setup, which makes it possible to carry out coincidence experiments at >100 kHz event frequencies. As examples, the threshold photoelectron spectrum of the argon dimer and the breakdown diagrams for hydrogen atom loss in room temperature methane and the chlorine atom loss in cold chlorobenzene are shown and discussed.

  7. Electron irradiation effect of polyurethane using coincidence doppler-broadening spectroscopy

    International Nuclear Information System (INIS)

    Yang, D.J.; Zhang, J.D.; Leung, J.K.C.; Beling, C.D.; Liu, L.B.

    2006-01-01

    Full text: To understand the electron irradiation effects on polymer, polyether-urethane (ETPU) samples of 2m m in thickness and 1 0 m m in diameter were irradiated by a 1.8M eV electron beam with beam current of 3 ma at room temperature. The irradiated doses are 5 kGy, 10 kGy, 15 kGy, 30 kGy, 100 kGy and 150 kGy. ETPU was manufactured by mixing PTMG-100, TDI-100 and MOCA. The momentum density distributions (MMDs) of electrons taking part in the annihilation processes of positron-electron pairs in ETPU have been measured by coincidence Doppler-broadening spectroscopy (CDBS). By presenting the ratio of the counts in every channel of the measured CDB spectrum to the corresponding counts from a reference spectrum (pristine ETPU), we observed that the change in MMDs is not significant for doses lower than 10 kGy. However, high momentum part of MMDs exhibit an obvious decrease for dose exceeding 15 kGy and then slowly down to steady with doses until 150 kGy. This valley occurs at around 15 x1 0 3m οc and is well known as oxygen-specific, indicative of a less positron trapping by oxygen atoms in some samples of higher dose radiation. It is postulated that the radiation will break the crosslinkings, allowing the trace water and oxygen molecules to be released from the sample surface. Excess NCO groups in ETPU would crosslink with urethane and urea groups to produce allophanate and biuret groups. After receiving a certain amount of electron irradiation, crosslinked allophanate and biuret groups would produce degradation. Thus, residual water and oxygen trapped in ETPU by the crosslinking would diffuse out. However, the irradiation doses up to 150 kGy in this experiment are still not large enough to induce strong degradation of urethane and urea groups

  8. Statistical Methods for Unusual Count Data

    DEFF Research Database (Denmark)

    Guthrie, Katherine A.; Gammill, Hilary S.; Kamper-Jørgensen, Mads

    2016-01-01

    microchimerism data present challenges for statistical analysis, including a skewed distribution, excess zero values, and occasional large values. Methods for comparing microchimerism levels across groups while controlling for covariates are not well established. We compared statistical models for quantitative...... microchimerism values, applied to simulated data sets and 2 observed data sets, to make recommendations for analytic practice. Modeling the level of quantitative microchimerism as a rate via Poisson or negative binomial model with the rate of detection defined as a count of microchimerism genome equivalents per...

  9. Comparison of least-squares vs. maximum likelihood estimation for standard spectrum technique of β−γ coincidence spectrum analysis

    International Nuclear Information System (INIS)

    Lowrey, Justin D.; Biegalski, Steven R.F.

    2012-01-01

    The spectrum deconvolution analysis tool (SDAT) software code was written and tested at The University of Texas at Austin utilizing the standard spectrum technique to determine activity levels of Xe-131m, Xe-133m, Xe-133, and Xe-135 in β–γ coincidence spectra. SDAT was originally written to utilize the method of least-squares to calculate the activity of each radionuclide component in the spectrum. Recently, maximum likelihood estimation was also incorporated into the SDAT tool. This is a robust statistical technique to determine the parameters that maximize the Poisson distribution likelihood function of the sample data. In this case it is used to parameterize the activity level of each of the radioxenon components in the spectra. A new test dataset was constructed utilizing Xe-131m placed on a Xe-133 background to compare the robustness of the least-squares and maximum likelihood estimation methods for low counting statistics data. The Xe-131m spectra were collected independently from the Xe-133 spectra and added to generate the spectra in the test dataset. The true independent counts of Xe-131m and Xe-133 are known, as they were calculated before the spectra were added together. Spectra with both high and low counting statistics are analyzed. Studies are also performed by analyzing only the 30 keV X-ray region of the β–γ coincidence spectra. Results show that maximum likelihood estimation slightly outperforms least-squares for low counting statistics data.

  10. Empirical Derivation of Correction Factors for Human Spiral Ganglion Cell Nucleus and Nucleolus Count Units.

    Science.gov (United States)

    Robert, Mark E; Linthicum, Fred H

    2016-01-01

    Profile count method for estimating cell number in sectioned tissue applies a correction factor for double count (resulting from transection during sectioning) of count units selected to represent the cell. For human spiral ganglion cell counts, we attempted to address apparent confusion between published correction factors for nucleus and nucleolus count units that are identical despite the role of count unit diameter in a commonly used correction factor formula. We examined a portion of human cochlea to empirically derive correction factors for the 2 count units, using 3-dimensional reconstruction software to identify double counts. The Neurotology and House Histological Temporal Bone Laboratory at University of California at Los Angeles. Using a fully sectioned and stained human temporal bone, we identified and generated digital images of sections of the modiolar region of the lower first turn of cochlea, identified count units with a light microscope, labeled them on corresponding digital sections, and used 3-dimensional reconstruction software to identify double-counted count units. For 25 consecutive sections, we determined that double-count correction factors for nucleus count unit (0.91) and nucleolus count unit (0.92) matched the published factors. We discovered that nuclei and, therefore, spiral ganglion cells were undercounted by 6.3% when using nucleolus count units. We determined that correction factors for count units must include an element for undercounting spiral ganglion cells as well as the double-count element. We recommend a correction factor of 0.91 for the nucleus count unit and 0.98 for the nucleolus count unit when using 20-µm sections. © American Academy of Otolaryngology—Head and Neck Surgery Foundation 2015.

  11. Hanford whole body counting manual

    International Nuclear Information System (INIS)

    Palmer, H.E.; Rieksts, G.A.; Lynch, T.P.

    1990-06-01

    This document describes the Hanford Whole Body Counting Program as it is administered by Pacific Northwest Laboratory (PNL) in support of the US Department of Energy--Richland Operations Office (DOE-RL) and its Hanford contractors. Program services include providing in vivo measurements of internally deposited radioactivity in Hanford employees (or visitors). Specific chapters of this manual deal with the following subjects: program operational charter, authority, administration, and practices, including interpreting applicable DOE Orders, regulations, and guidance into criteria for in vivo measurement frequency, etc., for the plant-wide whole body counting services; state-of-the-art facilities and equipment used to provide the best in vivo measurement results possible for the approximately 11,000 measurements made annually; procedures for performing the various in vivo measurements at the Whole Body Counter (WBC) and related facilities including whole body counts; operation and maintenance of counting equipment, quality assurance provisions of the program, WBC data processing functions, statistical aspects of in vivo measurements, and whole body counting records and associated guidance documents. 16 refs., 48 figs., 22 tabs

  12. Study of a 4πβ-γ coincidence system for absolute radionuclide activity measurement using plastic scintillators

    International Nuclear Information System (INIS)

    Piuvezam Filho, Helio

    2007-01-01

    The present work was intended to study a coincidence system 4π(PS)β-γ for absolute activity measurement using plastic scintillators in 4π geometry. Along with experiments on the coincidence system, simulations were also performed applying the Monte Carlo Method, by means of codes PENELOPE and ESQUEMA. These simulations were performed in order to calculate the extrapolation curve of the coincidence system 4π(PS)β-γ and compare it to experimental data. A new geometry was proposed to the coincidence system adding up a second photomultiplier tube to the previous system for improving light collection from the plastic scintillator, as this system presented limitations in the minimum detected energy due to the presence of electronic noise and low gain. The results show that an improvement in the signal-to-noise ratio was obtained, as well as in the minimum detected energy. Moreover, there was an increase in the detection efficiency. With these modifications, it is now possible to calibrate radionuclides which emit low energy electrons or X-rays, increasing the number of radionuclides that can be standardized with this type of system.(author)

  13. Temporal trends in sperm count

    DEFF Research Database (Denmark)

    Levine, Hagai; Jørgensen, Niels; Martino-Andrade, Anderson

    2017-01-01

    a predefined protocol 7518 abstracts were screened and 2510 full articles reporting primary data on SC were reviewed. A total of 244 estimates of SC and TSC from 185 studies of 42 935 men who provided semen samples in 1973-2011 were extracted for meta-regression analysis, as well as information on years.......006, respectively). WIDER IMPLICATIONS: This comprehensive meta-regression analysis reports a significant decline in sperm counts (as measured by SC and TSC) between 1973 and 2011, driven by a 50-60% decline among men unselected by fertility from North America, Europe, Australia and New Zealand. Because......BACKGROUND: Reported declines in sperm counts remain controversial today and recent trends are unknown. A definitive meta-analysis is critical given the predictive value of sperm count for fertility, morbidity and mortality. OBJECTIVE AND RATIONALE: To provide a systematic review and meta-regression...

  14. Performances evaluation of the coincidence detection on a gamma-camera

    International Nuclear Information System (INIS)

    Dreuille, O. de; Gaillard, J.F.; Brasse, D.; Bendriem, B.; Groiselle, C.; Rocchisani, J.M.; Moretti, J.L.

    2000-01-01

    The performance of the VERTEX gamma-camera (ADAC) working in coincidence mode are investigated using a protocol derived from the NEMA and IEC recommendations. With a field of view determined by two rectangular detectors (50.8 cm x 40 cm) composed of NaI crystal, this camera allows a 3-D acquisition with different energy window configurations: photopeak-photopeak only (PP) and photopeak-photopeak + photopeak-Compton (PC). An energy resolution of 11% and a scatter fraction of 27% and 33% for the 3D-PP and 3D-PC mode respectively are the main significant results of our study. The spatial resolution equals 5.9 mm and the limit of the detectability ranges from 16 mm to 13 mm for a contrast of 2.5: as a function of the random estimation, the maximum of the Noise Equivalent Count rate varies from 3 kcps to 4.5 kcps for the PP mode and from 3.85 kcps to 6.1 kcps for the PC mode. These maxima are reached for a concentration of 8 kBq/ml for the PP mode and 5 kBq/ml for the PC mode. These values are compared with the results obtained by other groups for the VERTEX gamma camera and several dedicated PET systems. (authors)

  15. Development of Simultaneous Beta-and-Coincidence-Gamma Imager for Plant Imaging Research

    Energy Technology Data Exchange (ETDEWEB)

    Tai, Yuan-Chuan [Washington Univ., St. Louis, MO (United States). School of Medicine

    2016-09-30

    The goal of this project is to develop a novel imaging system that can simultaneously acquire beta and coincidence gamma images of positron sources in thin objects such as leaves of plants. This hybrid imager can be used to measure carbon assimilation in plants quantitatively and in real-time after C-11 labeled carbon-dioxide is administered. A better understanding of carbon assimilation, particularly under the increasingly elevated atmospheric CO2 level, is extremely critical for plant scientists who study food crop and biofuel production. Phase 1 of this project is focused on the technology development with 3 specific aims: (1) develop a hybrid detector that can detect beta and gamma rays simultaneously; (2) develop an imaging system that can differentiate these two types of radiation and acquire beta and coincidence gamma images in real-time; (3) develop techniques to quantify radiotracer distribution using beta and gamma images. Phase 2 of this project is to apply technologies developed in phase 1 to study plants using positron-emitting radionuclide such as 11C to study carbon assimilation in biofuel plants.

  16. Monte Carlo simulation of activity measurements by means of 4πβ-γ coincidence system

    International Nuclear Information System (INIS)

    Takeda, Mauro N.; Dias, Mauro S.; Koskinas, Marina F.

    2004-01-01

    The methodology for simulating all detection processes in a 4πβ-γ coincidence system by means of the Monte Carlo technique is described. The goal is to predict the behavior of the observed activity as a function of the 4πβ detector efficiency. In this approach, the information contained in the decay scheme is used for determining the contribution of all radiations emitted by the selected radionuclide, to the measured spectra by each detector. This simulation yields the shape of the coincidence spectrum, allowing the choice of suitable gamma-ray windows for which the activity can be obtained with maximum accuracy. The simulation can predict a detailed description of the extrapolation curve, mainly in the region where the 4πβ detector efficiency approaches 100%, which is experimentally unreachable due to self absorption of low energy electrons in the radioactive source substrate. The theoretical work is being developed with MCNP Monte Carlo code, applied to a gas-flow proportional counter of 4π geometry, coupled to a pair of NaI(Tl) crystals. The calculated efficiencies are compared to experimental results. The extrapolation curve can be obtained by means of another Monte Carlo algorithm, being developed in the present work, to take into account fundamental characteristics of a complex decay scheme, including different types of radiation and transitions. The present paper shows preliminary calculated values obtained by the simulation and compared to predicted analytical values for a simple decay scheme. (author)

  17. Photon-counting image sensors

    CERN Document Server

    Teranishi, Nobukazu; Theuwissen, Albert; Stoppa, David; Charbon, Edoardo

    2017-01-01

    The field of photon-counting image sensors is advancing rapidly with the development of various solid-state image sensor technologies including single photon avalanche detectors (SPADs) and deep-sub-electron read noise CMOS image sensor pixels. This foundational platform technology will enable opportunities for new imaging modalities and instrumentation for science and industry, as well as new consumer applications. Papers discussing various photon-counting image sensor technologies and selected new applications are presented in this all-invited Special Issue.

  18. Analysis of 125Xe electron-photon coincidence decay

    International Nuclear Information System (INIS)

    Klingberg, F.J.; Biegalski, S.R.

    2016-01-01

    As part of the verification component of the Comprehensive Nuclear-Test-Ban Treaty (CTBT), environmental gas samples originating from nuclear fission are analyzed for the presence of 131m Xe, 133m Xe, 133 Xe, and 135 Xe. In this work, the non-traditional radioxenon isotope 125 Xe was investigated. The isotope was produced as an isotopically pure sample via neutron activation of 124 Xe at the University of Texas at Austin Nuclear Engineering Teaching Lab's TRIGA MARK II Reactor. The sample was then measured using a HPGe detector as well as an ARSA-style b-c coincidence detector. Potential sources and sensitivities for production of 125 Xe are also considered for relevance to the CTBT verification mission. (author)

  19. Positron emission tomography with gamma camera in coincidence mode

    International Nuclear Information System (INIS)

    Hertel, A.; Hoer, G.

    1999-01-01

    Positron emission tomography using F-18 FDG has been estbalished in clinical diagnostics with first indications especially in oncology. To install a conventional PET tomography (dedicated PET) is financially costly and restricted to PET examinations only. Increasing demand for PET diagnostics on one hand and restricted financial resources in the health system on the other hand led industry to develop SPECT cameras to be operated in coincidence mode (camera PET) in order to offer nuclear medicine physicians cost-effective devices for PET diagnostic. At the same time camera PET is inferior to conventional PET regarding sensitivity and detection-efficiency for 511 keV photons. Does camera-PET offer a reliable alternative to conventional PET? The first larger comparative studies are now available, so a first apraisal about the technical clinical performance of camera-PET can be done. (orig.) [de

  20. Airborne LIDAR borsight error calibration based on surface coincide

    International Nuclear Information System (INIS)

    Yuan, Fangyan; Li, Guoqing; Zuo, Zhengli; Li, Dong; Qi, Zengying; Qiu, Wen; Tan, Junxiang

    2014-01-01

    Light Detection and Ranging (LIDAR) is a system which can directly collect three-dimensional coordinate information of ground point and laser reflection strength information. With the wide application of LIDAR system, users hope to get more accurate results. Boresight error has an important effect on data accuracy and thus, it is thought that eliminating the error is very important. In recent years, many methods have been proposed to eliminate the error. Generally, they can be categorized into tie point method and surface matching method. In this paper, we propose another method called try value method based on surface coincide that is used in actual production by many companies. The method is simple and operable. Further, the efficacy of the method was demonstrated by analyzing the data from Zhangye city

  1. On the spatial coincidence of hydroxyl and methanol masers

    Science.gov (United States)

    Hartquist, T. W.; Menten, K. M.; Lepp, S.; Dalgarno, A.

    1995-01-01

    We argue that purely gas-phase chemical models for the production of OH in hydroxyl masers around ultracompact H II regions such as W3(OH) cannot account for the CH_3OH in the methanol masers that are found to coincide with the hydroxyl masers in these sources. We suggest that the CH_3OH in the masers is injected into the gas phase by evaporation of the grain mantles, the grains being heated by the passage of weak shocks. Gas evaporation also injects H_2O into the gas. Photodissociation of H_2O, CH_3OH and OH occur at similar rates, and substantial abundances of CH_3OH and OH coexist.

  2. The spallation in reverse kinematics: what for a coincidence measurement?

    International Nuclear Information System (INIS)

    Ducret, J.E.

    2006-07-01

    The Spaladin installation has been designed to study spallation reactions in reverse kinematics. Furthermore, the heavy and light fragments are detected by coincidence which allows us to get an instantaneous picture of the reaction at a level of accuracy better than that obtained through inclusive measurement. The first part is dedicated to the theoretical description of the different mechanisms involved in the spallation reactions. In the second part we describe the Spaladin installation and report some results on the reaction: Fe 56 + p at an energy of 1 GeV/nucleon. In the third part we expose the performance of the installation through its simulation with the Geant-IV model. We present a study about the sensitivity of the Spaladin installation to theoretical predictions. The fourth part is dedicated to the future experiments that will be performed with the Spaladin installation. (A.C.)

  3. Passive Time Coincidence Measurements with HEU and DU Metal Castings

    International Nuclear Information System (INIS)

    McConchie, Seth M.; Hausladen, Paul; Mihalczo, John T.; Wright, Michael C.; Archer, Daniel E.

    2008-01-01

    A Department of Energy sponsored Oak Ridge National Laboratory/Y-12 National Security Complex program of passive time coincidence measurements has been initiated at Y-12 to evaluate the ability to determine the presence of high enriched uranium (HEU) and distinguish it from depleted uranium (DU). This program uses the Nuclear Materials Identification System (NMIS) without an active interrogation source. Previous passive NMIS measurements with Pu metal and Pu oxide have been successful in determining the Pu mass, assuming a known 240Pu content. The spontaneous fission of uranium metal is considerably lower than Pu and measurements of this type have been performed at Lawrence Livermore National Laboratory. This work presents results of measurements of HEU and DU metal castings using moderated 3He detectors.

  4. Coincident photoelectron spectroscopy on superconductors; Koinzidente Photoelektronenspektroskopie an Supraleitern

    Energy Technology Data Exchange (ETDEWEB)

    Voss, Stefan

    2011-07-01

    Aim of the performed experiments of this thesis was to attempt to detect Cooper pairs as carriers of the superconducting current directly by means of the photoelectric effect. The method of the coincident photoelectron spectroscopy aims thereby at the detection of two coherently emitted electrons by the interaction with a photon. Because electrostatic analyzers typically cover only a very small spatial angle, which goes along with very low coincidence rates, in connection with this thesis a time-of-flight projection system has been developed, which maps nearly the whole spatial angle on a position-resolving detector. The pulsed light source in form of special synchrotron radiation necessary for the measurement has been adjusted so weak, that only single photons could arrive at the sample. Spectroscoped were beside test measurements on silver layers both a lead monocrystal as representative of the classical BCS superconductors and monocrystalline Bi{sub 2}Sr{sub 2}CaCu{sub 2}O{sub 8} from the family of the high-temperature superconductors. With excitation energies up to 40 eV could be shown that sufficiently smooth and clean surfaces in the superconducting phase exhibit within the resolving power of about 0.5 eV no recognizable differences in comparison to the normally conducting phase. Beside these studies furthermore the simple photoemission at the different samples and especially in the case of the lead crystal is treated, because here no comparable results are known. Thereby the whole momentum space is discussed and the Fermi surface established as three-dimensional model, by means of which the measurement results are discussed. in the theoretical descriptions different models for the Cooper-pair production are presented, whereby to the momentum exchange with the crystal a special role is attributed, because this can only occur in direct excitations via discrete lattice vectors.

  5. Determination of cosmic ray produced radionuclides by means of background radiation counting system, 3

    International Nuclear Information System (INIS)

    1976-01-01

    This is the third report of the progress report series on studies of cosmic ray produced radionuclides by means of low background radiation counting system. In Part I some characteristics of a low beta-gamma coincidence spectrometer are described -- counter system, electronics, background spectra, counting efficiencies -- and studies on radioactive impurities in materials for scientific research are also described. In Part II, suitable solvents for a large scale liquid scintillation counter were examined and best combinations of solvents, solutes and naphthalene are shown. In Part III, miscellaneous topics are reported. (auth.)

  6. Automation system for optical counting of nuclear tracks

    Energy Technology Data Exchange (ETDEWEB)

    Boulyga, S.F.; Boulyga, E.G.; Lomonosova, E.M.; Zhuk, I.V

    1999-06-01

    An automation system consisting of the microscope, video camera and Pentium PC with frame recorder was created. The system provides counting of nuclear tracks on the SSNTD surface with a resolution of 752 x 582 points, determination of the surface area and main axis of the track. The pattern recognition program was developed for operation in Windows 3.1 (or higher) ensuring a convenient interface with the user. In a comparison of the results on automatic track counting with the more accurate hand mode it was shown that the program enables the tracks to be detected even on images with a rather high noise level. It ensures a high accuracy of track counting being comparable with the accuracy of manual counting for densities of tracks in the range of up to 2{center_dot}10{sup 5} tracks/cm{sup 2}. The automatic system was applied in the experimental investigation of uranium and transuranium elements.

  7. Automation system for optical counting of nuclear tracks

    International Nuclear Information System (INIS)

    Boulyga, S.F.; Boulyga, E.G.; Lomonosova, E.M.; Zhuk, I.V.

    1999-01-01

    An automation system consisting of the microscope, video camera and Pentium PC with frame recorder was created. The system provides counting of nuclear tracks on the SSNTD surface with a resolution of 752 x 582 points, determination of the surface area and main axis of the track. The pattern recognition program was developed for operation in Windows 3.1 (or higher) ensuring a convenient interface with the user. In a comparison of the results on automatic track counting with the more accurate hand mode it was shown that the program enables the tracks to be detected even on images with a rather high noise level. It ensures a high accuracy of track counting being comparable with the accuracy of manual counting for densities of tracks in the range of up to 2·10 5 tracks/cm 2 . The automatic system was applied in the experimental investigation of uranium and transuranium elements

  8. Automation system for optical counting of nuclear tracks

    CERN Document Server

    Boulyga, S F; Lomonosova, E M; Zhuk, I V

    1999-01-01

    An automation system consisting of the microscope, video camera and Pentium PC with frame recorder was created. The system provides counting of nuclear tracks on the SSNTD surface with a resolution of 752 x 582 points, determination of the surface area and main axis of the track. The pattern recognition program was developed for operation in Windows 3.1 (or higher) ensuring a convenient interface with the user. In a comparison of the results on automatic track counting with the more accurate hand mode it was shown that the program enables the tracks to be detected even on images with a rather high noise level. It ensures a high accuracy of track counting being comparable with the accuracy of manual counting for densities of tracks in the range of up to 2 centre dot 10 sup 5 tracks/cm sup 2. The automatic system was applied in the experimental investigation of uranium and transuranium elements.

  9. Pedestrian count estimation using texture feature with spatial distribution

    Directory of Open Access Journals (Sweden)

    Hongyu Hu

    2016-12-01

    Full Text Available We present a novel pedestrian count estimation approach based on global image descriptors formed from multi-scale texture features that considers spatial distribution. For regions of interest, local texture features are represented based on histograms of multi-scale block local binary pattern, which jointly constitute the feature vector of the whole image. Therefore, to achieve an effective estimation of pedestrian count, principal component analysis is used to reduce the dimension of the global representation features, and a fitting model between image global features and pedestrian count is constructed via support vector regression. The experimental result shows that the proposed method exhibits high accuracy on pedestrian count estimation and can be applied well in the real world.

  10. Daily variability of strongyle fecal egg counts in horses

    DEFF Research Database (Denmark)

    Carstensen, Helena; Larsen, Lene; Ritz, Christian

    2013-01-01

    Strongyle parasites are ubiquitous in grazing horses and constitute a potential threat to equine health. Feces were collected from six horses four times daily over a period of 5 days. Fecal egg counts (FECs) were performed to identify any diurnal rhythms in strongyle egg shedding and to quantify...... variability at the different levels: individual horses, repeated counts, repeated subsamples, different time points, and different days. No significant differences in FECs were found between the different time points (P = .11). The variables-horse, day, subsample, and egg count-accounted for a variance of 104...... subsamples and repeated egg counts on the same subsamples, whereas the variability of FECs between following days can be considered negligible. The findings of this study have implication for designing and performing field surveillance of strongyle FEC levels and applying the FEC reduction test...

  11. Liquid scintillation, counting, and compositions

    International Nuclear Information System (INIS)

    Sena, E.A.; Tolbert, B.M.; Sutula, C.L.

    1975-01-01

    The emissions of radioactive isotopes in both aqueous and organic samples can be measured by liquid scintillation counting in micellar systems. The micellar systems are made up of scintillation solvent, scintillation solute and a mixture of surfactants, preferably at least one of which is relatively oil-soluble water-insoluble and another which is relatively water-soluble oil-insoluble

  12. Phase space quark counting rule

    International Nuclear Information System (INIS)

    Wei-gin, C.; Lo, S.

    1980-01-01

    A simple quark counting rule based on phase space consideration suggested before is used to fit all 39 recent experimental data points on inclusive reactions. Parameter free relations are found to agree with experiments. Excellent detail fits are obtained for 11 inclusive reactions

  13. Counting a Culture of Mealworms

    Science.gov (United States)

    Ashbrook, Peggy

    2007-01-01

    Math is not the only topic that will be discussed when young children are asked to care for and count "mealworms," a type of insect larvae (just as caterpillars are the babies of butterflies, these larvae are babies of beetles). The following activity can take place over two months as the beetles undergo metamorphosis from larvae to adults. As the…

  14. Counting problems for number rings

    NARCIS (Netherlands)

    Brakenhoff, Johannes Franciscus

    2009-01-01

    In this thesis we look at three counting problems connected to orders in number fields. First we study the probability that for a random polynomial f in Z[X] the ring Z[X]/f is the maximal order in Q[X]/f. Connected to this is the probability that a random polynomial has a squarefree

  15. On Counting the Rational Numbers

    Science.gov (United States)

    Almada, Carlos

    2010-01-01

    In this study, we show how to construct a function from the set N of natural numbers that explicitly counts the set Q[superscript +] of all positive rational numbers using a very intuitive approach. The function has the appeal of Cantor's function and it has the advantage that any high school student can understand the main idea at a glance…

  16. Vote Counting as Mathematical Proof

    DEFF Research Database (Denmark)

    Schürmann, Carsten; Pattinson, Dirk

    2015-01-01

    then consists of a sequence (or tree) of rule applications and provides an independently checkable certificate of the validity of the result. This reduces the need to trust, or otherwise verify, the correctness of the vote counting software once the certificate has been validated. Using a rule...

  17. Counting SET-free sets

    OpenAIRE

    Harman, Nate

    2016-01-01

    We consider the following counting problem related to the card game SET: How many $k$-element SET-free sets are there in an $n$-dimensional SET deck? Through a series of algebraic reformulations and reinterpretations, we show the answer to this question satisfies two polynomiality conditions.

  18. Repeatability of differential goat bulk milk culture and associations with somatic cell count, total bacterial count, and standard plate count

    OpenAIRE

    Koop, G.; Dik, N.; Nielen, M.; Lipman, L.J.A.

    2010-01-01

    The aims of this study were to assess how different bacterial groups in bulk milk are related to bulk milk somatic cell count (SCC), bulk milk total bacterial count (TBC), and bulk milk standard plate count (SPC) and to measure the repeatability of bulk milk culturing. On 53 Dutch dairy goat farms, 3 bulk milk samples were collected at intervals of 2 wk. The samples were cultured for SPC, coliform count, and staphylococcal count and for the presence of Staphylococcus aureus. Furthermore, SCC ...

  19. Analysis method for beta-gamma coincidence spectra from radio-xenon isotopes

    International Nuclear Information System (INIS)

    Yang Wenjing; Yin Jingpeng; Huang Xiongliang; Cheng Zhiwei; Shen Maoquan; Zhang Yang

    2012-01-01

    Radio-xenon isotopes monitoring is one important method for the verification of CTBT, what includes the measurement methods of HPGe γ spectrometer and β-γ coincidence. The article describes the analytic flowchart and method of three-dimensional beta-gamma coincidence spectra from β-γ systems, and analyses in detail the principles and methods of the regions of interest of coincidence spectra and subtracting the interference, finally gives the formula of radioactivity of Xenon isotopes and minimum detectable concentrations. Studying on the principles of three-dimensional beta-gamma coincidence spectra, which can supply the foundation for designing the software of β-γ coincidence systems. (authors)

  20. Application of RI-counting method for posttraumatic CSF rhinorrhea

    International Nuclear Information System (INIS)

    Itoh, Takahiko; Terai, Yoshinori; Fujimoto, Shunichiro; Kawauchi, Masamitsu.

    1987-01-01

    Numerous techniques and procedures have been reported for the evaluation of CSF fistulas. Especially metrizamide CT cisternography and radioisotope (RI) cisternography have been reported to be reliable for localizing the site of CSF leakage, however, it has been difficult to diagnose the existence and the site of CSF leakages in some cases. RI-counting method, measuring RI-count of intranasal cotton pledgets after the intrathecal injection of RI ( 111 In-DTPA) is thought to be the most reliable method for detecting the presence of CSF leakage in these cases. We used six cotton pledgets which were inserted into upper, middle, and lower meatuses on both side. Because the site of pledgets with ghest RI-count has anatomical relationship to the opening of the paranasal sinus, we can surmise the leakage of dural defect and CSF leakage. RI counting method was applied to two patients in whom it was difficult to diagnose the presence of CSF leakage with other procedures. The patients were free in position for four hours after the intrathecal injection of RI, and in the prone position for 30 minutes before RI-counting of intranasal cotton pledgets. After measuring the RI-counts of six pledgets, the counts were compared with each other. The cotton pledget inserted into left middle meatus showed the highest count in both cases. From this result and finding of conventional skull tomography we speculated the site of CSF leakage to be frontal sinus or ethmoid sinus. Operation demonstrated the opening of dura into the frontal sinus in one case, and ethmoid sinus in another case. As mentioned above, RI-counting method has the advantages of detecting the existence and the site of CSF leakage. (author)

  1. Modular routing interface for simoultaneous list mode and histogramming mode storage of coincident data

    International Nuclear Information System (INIS)

    D'Achard van Eschut, J.F.M.; Nationaal Inst. voor Kernfysica en Hoge-Energiefysica

    1985-01-01

    A routing interface has been developed and built for successive storage of the digital output of four 13-bit ADCs, within 6 μs, into selected parts of two 16K CAMAC histogramming modules and, if an event trigger is applied, simultaneously into four 64-words deep (16-bit) first-in first-out (FIFO) CAMAC modules. In this way it is possible to accumulate on-line single spectra and, at the same time, write coincident data in list mode to magnetic tape under control of a computer. Additional routing interfaces can be used in parallel so that extensive data-collecting systems can be set up to store multi-parameter events. (orig.)

  2. Coincidence Doppler broadening study on hydrocarbons with pi and sigma valence electrons: positronium correction

    International Nuclear Information System (INIS)

    Djourelov, N.; Suzuki, T.; Yu, R.S.; Ito, Y.

    2005-01-01

    The coincidence Doppler broadening (CDB) technique was applied to study the electron momentum distribution in anthracene, diphenyl, naphthalene, and polystyrene. A method for separation of the positron and positronium (Ps) components from the Doppler-broadened annihilation line (DBAL) was developed further to be applicable to hydrocarbons with different π and σ valence electron distributions. This method allows extraction of the electron momentum distribution (EMD) from DBAL for samples when Ps formation occurs. The annihilation on π valence electrons was detected as broadening of the EMD compared to that obtained for a polymer sample only with σ valence electrons. The broadening appeared as a significant change in the shape of the CDB ratio of the corresponding positronium-corrected curves: a slight enhancement above the unity line in the low-momentum region and a drop in the momentum region, 10-20x10 -3 m o c

  3. Coincidence of asthma and bronchospasm during anesthesia in tympanomastoidectomy.

    Science.gov (United States)

    Hosseinzadeh, Nima; Samadi, Shahram; Amali, Amin; Jafari Javid, Mihan

    2014-01-01

    High prevalence of asthma and bronchospasm was observed during induction of anesthesia in patients with chronic suppurative otitis mMedia (CSOM) who underwent tympanomastoidectomy. Although several studies have proposed association of allergic diseases with CSOM but no consensus about it has been established. Current study was designed to determine the coincidence of asthma in CSOM patients. In a cross-sectional study, authors investigated medical records of 106 CSOM patients underwent tympanomastoidectomy, aged 15 to 65 years, and 95 controls, which were matched by age and sex. Participants were admitted to Valiasr Hospital, Tehran, Iran, from April of 2011 to March of 2013. Required information, such as demographic characteristics and history of allergic rhinitis (AR) and asthma were obtained from patients' medical records. The prevalence of AR in the CSOM group was higher than controls' group (19.8% and 15.8%, respectively) (P>0.05). Asthma prevalence was significantly higher in patients with CSOM (P=0.03) (OR=7.67, 95% CI:  0.9-62.5). No significant association was found between history of AR and chronic ear infections. However, asthma was significantly more common in CSOM patients. Current study indicates that asthma and risk of bronchospasm need particular attention in patients with CSOM underwent tympanomastoidectomy before and during anesthesia.

  4. Coincidence of asthma and bronchospasm during anesthesia in tympanomastoidectomy.

    Directory of Open Access Journals (Sweden)

    Nima Hosseinzadeh

    2014-12-01

    Full Text Available High prevalence of asthma and bronchospasm was observed during induction of anesthesia in patients with chronic suppurative otitis mMedia (CSOM who underwent tympanomastoidectomy. Although several studies have proposed association of allergic diseases with CSOM but no consensus about it has been established. Current study was designed to determine the coincidence of asthma in CSOM patients. In a cross-sectional study, authors investigated medical records of 106 CSOM patients underwent tympanomastoidectomy, aged 15 to 65 years, and 95 controls, which were matched by age and sex. Participants were admitted to Valiasr Hospital, Tehran, Iran, from April of 2011 to March of 2013. Required information, such as demographic characteristics and history of allergic rhinitis (AR and asthma were obtained from patients' medical records. The prevalence of AR in the CSOM group was higher than controls' group (19.8% and 15.8%, respectively (P>0.05. Asthma prevalence was significantly higher in patients with CSOM (P=0.03 (OR=7.67, 95% CI:  0.9-62.5. No significant association was found between history of AR and chronic ear infections. However, asthma was significantly more common in CSOM patients. Current study indicates that asthma and risk of bronchospasm need particular attention in patients with CSOM underwent tympanomastoidectomy before and during anesthesia.

  5. Intrinsic coincident full-Stokes polarimeter using stacked organic photovoltaics.

    Science.gov (United States)

    Yang, Ruonan; Sen, Pratik; O'Connor, B T; Kudenov, M W

    2017-02-20

    An intrinsic coincident full-Stokes polarimeter is demonstrated by using strain-aligned polymer-based organic photovoltaics (OPVs) that can preferentially absorb certain polarized states of incident light. The photovoltaic-based polarimeter is capable of measuring four Stokes parameters by cascading four semitransparent OPVs in series along the same optical axis. This in-line polarimeter concept potentially ensures high temporal and spatial resolution with higher radiometric efficiency as compared to the existing polarimeter architecture. Two wave plates were incorporated into the system to modulate the S3 Stokes parameter so as to reduce the condition number of the measurement matrix and maximize the measured signal-to-noise ratio. Radiometric calibration was carried out to determine the measurement matrix. The polarimeter presented in this paper demonstrated an average RMS error of 0.84% for reconstructed Stokes vectors after normalized to S0. A theoretical analysis of the minimum condition number of the four-cell OPV design showed that for individually optimized OPV cells, a condition number of 2.4 is possible.

  6. Theory of photoelectron counting statistics

    International Nuclear Information System (INIS)

    Blake, J.

    1980-01-01

    The purpose of the present essay is to provide a detailed analysis of those theoretical aspects of photoelectron counting which are capable of experimental verification. Most of our interest is in the physical phenomena themselves, while part is in the mathematical techniques. Many of the mathematical methods used in the analysis of the photoelectron counting problem are generally unfamiliar to physicists interested in the subject. For this reason we have developed the essay in such a fashion that, although primary interest is focused on the physical phenomena, we have also taken pains to carry out enough of the analysis so that the reader can follow the main details. We have chosen to present a consistently quantum mechanical version of the subject, in that we follow the Glauber theory throughout. (orig./WL)

  7. Bayesian Kernel Mixtures for Counts.

    Science.gov (United States)

    Canale, Antonio; Dunson, David B

    2011-12-01

    Although Bayesian nonparametric mixture models for continuous data are well developed, there is a limited literature on related approaches for count data. A common strategy is to use a mixture of Poissons, which unfortunately is quite restrictive in not accounting for distributions having variance less than the mean. Other approaches include mixing multinomials, which requires finite support, and using a Dirichlet process prior with a Poisson base measure, which does not allow smooth deviations from the Poisson. As a broad class of alternative models, we propose to use nonparametric mixtures of rounded continuous kernels. An efficient Gibbs sampler is developed for posterior computation, and a simulation study is performed to assess performance. Focusing on the rounded Gaussian case, we generalize the modeling framework to account for multivariate count data, joint modeling with continuous and categorical variables, and other complications. The methods are illustrated through applications to a developmental toxicity study and marketing data. This article has supplementary material online.

  8. Card counting in continuous time

    OpenAIRE

    Andersson, Patrik

    2012-01-01

    We consider the problem of finding an optimal betting strategy for a house-banked casino card game that is played for several coups before reshuffling. The sampling without replacement makes it possible to take advantage of the changes in the expected value as the deck is depleted, making large bets when the game is advantageous. Using such a strategy, which is easy to implement, is known as card counting. We consider the case of a large number of decks, making an approximat...

  9. Monitoring Milk Somatic Cell Counts

    Directory of Open Access Journals (Sweden)

    Gheorghe Şteţca

    2014-11-01

    Full Text Available The presence of somatic cells in milk is a widely disputed issue in milk production sector. The somatic cell counts in raw milk are a marker for the specific cow diseases such as mastitis or swollen udder. The high level of somatic cells causes physical and chemical changes to milk composition and nutritional value, and as well to milk products. Also, the mastitic milk is not proper for human consumption due to its contribution to spreading of certain diseases and food poisoning. According to these effects, EU Regulations established the maximum threshold of admitted somatic cells in raw milk to 400000 cells / mL starting with 2014. The purpose of this study was carried out in order to examine the raw milk samples provided from small farms, industrial type farms and milk processing units. There are several ways to count somatic cells in milk but the reference accepted method is the microscopic method described by the SR EN ISO 13366-1/2008. Generally samples registered values in accordance with the admissible limit. By periodical monitoring of the somatic cell count, certain technological process issues are being avoided and consumer’s health ensured.

  10. The Spectra Count Label-free Quantitation in Cancer Proteomics

    OpenAIRE

    Zhou, Weidong; Liotta, Lance A.; Petricoin, Emanuel F.

    2012-01-01

    Mass spectrometry is used routinely for large-scale protein identification from complex biological mixtures. Recently, relative quantitation approach on the basis of spectra count has been applied in several cancer proteomic studies. In this review, we examine the mechanism of this technique and highlight several important parameters associated with its application.

  11. Data process of liquid scintillation counting

    International Nuclear Information System (INIS)

    Ishikawa, Hiroaki; Kuwajima, Susumu.

    1975-01-01

    The use of liquid scintillation counting system has been significantly spread because automatic sample changers and printers have recently come to be incorporated. However, the system will be systematized completely if automatic data processing and the sample preparation of radioactive materials to be measured are realized. Dry or wet oxidation method is applied to the sample preparation when radioactive materials are hard to dissolve into scintillator solution. Since these several years, the automatic sample combustion system, in which the dry oxidation is automated, has been rapidly spread and serves greatly to labor saving. Since the printers generally indicate only counted number, data processing system has been developed, and speeded up calculating process, which automatically corrects quenching of samples for obtaining the final radioactivity required. The data processing system is roughly divided into on-line and off-line systems according to whether computers are connected directly or indirectly, while its hardware is classified to input, calculating and output devices. Also, the calculation to determine sample activity by external standard method is explained. (Wakatsuki, Y.)

  12. Upper limits from counting experiments with multiple pipelines

    International Nuclear Information System (INIS)

    Sutton, Patrick J

    2009-01-01

    In counting experiments, one can set an upper limit on the rate of a Poisson process based on a count of the number of events observed due to the process. In some experiments, one makes several counts of the number of events, using different instruments, different event detection algorithms or observations over multiple time intervals. We demonstrate how to generalize the classical frequentist upper limit calculation to the case where multiple counts of events are made over one or more time intervals using several (not necessarily independent) procedures. We show how different choices of the rank ordering of possible outcomes in the space of counts correspond to applying different levels of significance to the various measurements. We propose an ordering that is matched to the sensitivity of the different measurement procedures and show that in typical cases it gives stronger upper limits than other choices. As an example, we show how this method can be applied to searches for gravitational-wave bursts, where multiple burst-detection algorithms analyse the same data set, and demonstrate how a single combined upper limit can be set on the gravitational-wave burst rate.

  13. Coincident Observations of Surface Ozone and NMVOCs over Abu Dhabi

    Science.gov (United States)

    Abbasi, Naveed; Majeed, Tariq; Iqbal, Mazhar; Tarasick, David; Davies, Jonathan; Riemer, Daniel; Apel, Eric

    2016-07-01

    The vertical profiles of ozone are measured coincidently with non-methane volatile organic compounds (NMVOCs) at the meteorological site located at the Abu Dhabi international airport (latitude 24.45N; longitude 54.22E) during the years 2012 - 2014. Some of the profiles show elevated surface ozone >95 ppbv during the winter months (December, January and February). The ground-level NMVOCs obtained from the gas chromatography-flame ionization detection/mass spectrometry system also show elevated values of acetylene, ethane, propane, butane, pentane, benzene, and toluene. NMVOCs and ozone abundances in other seasons are much lower than the values in winter season. NMVOCs are emitted from an extensive number of sources in urban environments including fuel production, distribution, and consumption, and serve as precursor of ozone. Transport sources contribute a substantial portion of the NMVOC burden to the urban atmosphere in developed regions. Abu Dhabi is located at the edge of the Arabian Gulf and is highly affected by emissions from petrochemical industries in the neighboring Gulf region. The preliminary results indicate that wintertime enhancement in ozone is associated with large values of NMVOCs at Abu Dhabi. The domestic production of surface ozone is estimated from the combination of oxygen recombination and NMVOCs and compared with the data. It is estimated that about 40-50% of ozone in Abu Dhabi is transported from the neighbouring petrochemical industries. We will present ozone sounding and NMVOCs data and our model estimates of surface ozone, including a discussion on the high levels of the tropospheric ozone responsible for contaminating the air quality in the UAE. This work is supported by National Research Foundation, UAE.

  14. The value of attenuation correction in dual-head coincidence imaging

    International Nuclear Information System (INIS)

    Shi Yiping; Huang Gang; Liu Jianjun

    2004-01-01

    Objective: To elucidate the value of attenuation correction (AC) in dual-head coincidence imaging by comparison of phantom and patients images with and without AC. Methods: We used a 20-cm-diameter cylindrical phantom, which contains four spheres of inside diameters of 1.4-2.9 cm for phantom study (1.4 cm, n=2; 2.0 cm, n=l; 2.9 cm, n=1). The axial length of the phantom was 30 cm. The wall thickness of the spheres was 1 mm. Both the phantom and spheres were filled with a solution that contained 18F-FDG. Three acquisitions were performed with the concentrations adjusted to provide a ratio of sphere-to-background activity of 3:1, 5:1 and 10:1. There were 38 patients (30 men and 8 women, age range 31 to 78 years) with suspected lung cancer included in clinical study. All patients were performed pneumonectomies and verified by histopathology. The histological tumor types were adenocarcinoma (n=11), squamous carcinoma (n=8), adenosquamous carcinoma (n=4), large cell carcinoma (n=2), neuroendocrine carcinoma (n=l), metastatic carcinoma (n=4), bronchiolo-alveolar carcinoma (n=1) and benign mass (n=7). The patients were fasted for at least 6 hours before the start of the study. Sixty minutes after intravenous administration of 111-185MBq (3-5mCi) 18F-FDG, emission scanning was performed using a dual-head gamma camera with a 128x128x16 matrix, with energy windows of 511 keV, 180 degree rotation, 32 steps and an acquisition time of 40 s per step. Subsequently, transmission scanning was performed with energy windows of 662 keV, 360 degree rotation, 96 steps and an acquisition time of 2s per step. The coincidence gamma camera imaging data were reconstructed by MCD iterative Methods with a Wiener filter (noise factor 0.75, pixel size 3.95 mm 3 ). Visual analysis and semiquantitative analysis were performed in AC and NAC images. For visual interpretation, a positive lesion was defined as any activity above local background. The count ratio of tumor to surrounded normal tissue (T

  15. Coincidence and coherent data analysis methods for gravitational wave bursts in a network of interferometric detectors

    International Nuclear Information System (INIS)

    Arnaud, Nicolas; Barsuglia, Matteo; Bizouard, Marie-Anne; Brisson, Violette; Cavalier, Fabien; Davier, Michel; Hello, Patrice; Kreckelbergh, Stephane; Porter, Edward K.

    2003-01-01

    Network data analysis methods are the only way to properly separate real gravitational wave (GW) transient events from detector noise. They can be divided into two generic classes: the coincidence method and the coherent analysis. The former uses lists of selected events provided by each interferometer belonging to the network and tries to correlate them in time to identify a physical signal. Instead of this binary treatment of detector outputs (signal present or absent), the latter method involves first the merging of the interferometer data and looks for a common pattern, consistent with an assumed GW waveform and a given source location in the sky. The thresholds are only applied later, to validate or not the hypothesis made. As coherent algorithms use more complete information than coincidence methods, they are expected to provide better detection performances, but at a higher computational cost. An efficient filter must yield a good compromise between a low false alarm rate (hence triggering on data at a manageable rate) and a high detection efficiency. Therefore, the comparison of the two approaches is achieved using so-called receiving operating characteristics (ROC), giving the relationship between the false alarm rate and the detection efficiency for a given method. This paper investigates this question via Monte Carlo simulations, using the network model developed in a previous article. Its main conclusions are the following. First, a three-interferometer network such as Virgo-LIGO is found to be too small to reach good detection efficiencies at low false alarm rates: larger configurations are suitable to reach a confidence level high enough to validate as true GW a detected event. In addition, an efficient network must contain interferometers with comparable sensitivities: studying the three-interferometer LIGO network shows that the 2-km interferometer with half sensitivity leads to a strong reduction of performances as compared to a network of three

  16. Coincidence and covariance data acquisition in photoelectron and -ion spectroscopy. II. Analysis and applications

    Science.gov (United States)

    Mikosch, Jochen; Patchkovskii, Serguei

    2013-10-01

    We use an analytical theory of noisy Poisson processes, developed in the preceding companion publication, to compare coincidence and covariance measurement approaches in photoelectron and -ion spectroscopy. For non-unit detection efficiencies, coincidence data acquisition (DAQ) suffers from false coincidences. The rate of false coincidences grows quadratically with the rate of elementary ionization events. To minimize false coincidences for rare event outcomes, very low event rates may hence be required. Coincidence measurements exhibit high tolerance to noise introduced by unstable experimental conditions. Covariance DAQ on the other hand is free of systematic errors as long as stable experimental conditions are maintained. In the presence of noise, all channels in a covariance measurement become correlated. Under favourable conditions, covariance DAQ may allow orders of magnitude reduction in measurement times. Finally, we use experimental data for strong-field ionization of 1,3-butadiene to illustrate how fluctuations in experimental conditions can contaminate a covariance measurement, and how such contamination can be detected.

  17. An automated approach for annual layer counting in ice cores

    Science.gov (United States)

    Winstrup, M.; Svensson, A.; Rasmussen, S. O.; Winther, O.; Steig, E.; Axelrod, A.

    2012-04-01

    The temporal resolution of some ice cores is sufficient to preserve seasonal information in the ice core record. In such cases, annual layer counting represents one of the most accurate methods to produce a chronology for the core. Yet, manual layer counting is a tedious and sometimes ambiguous job. As reliable layer recognition becomes more difficult, a manual approach increasingly relies on human interpretation of the available data. Thus, much may be gained by an automated and therefore objective approach for annual layer identification in ice cores. We have developed a novel method for automated annual layer counting in ice cores, which relies on Bayesian statistics. It uses algorithms from the statistical framework of Hidden Markov Models (HMM), originally developed for use in machine speech recognition. The strength of this layer detection algorithm lies in the way it is able to imitate the manual procedures for annual layer counting, while being based on purely objective criteria for annual layer identification. With this methodology, it is possible to determine the most likely position of multiple layer boundaries in an entire section of ice core data at once. It provides a probabilistic uncertainty estimate of the resulting layer count, hence ensuring a proper treatment of ambiguous layer boundaries in the data. Furthermore multiple data series can be incorporated to be used at once, hence allowing for a full multi-parameter annual layer counting method similar to a manual approach. In this study, the automated layer counting algorithm has been applied to data from the NGRIP ice core, Greenland. The NGRIP ice core has very high temporal resolution with depth, and hence the potential to be dated by annual layer counting far back in time. In previous studies [Andersen et al., 2006; Svensson et al., 2008], manual layer counting has been carried out back to 60 kyr BP. A comparison between the counted annual layers based on the two approaches will be presented

  18. Repeatability of differential goat bulk milk culture and associations with somatic cell count, total bacterial count, and standard plate count

    NARCIS (Netherlands)

    Koop, G.; Dik, N.; Nielen, M.; Lipman, L.J.A.

    2010-01-01

    The aims of this study were to assess how different bacterial groups in bulk milk are related to bulk milk somatic cell count (SCC), bulk milk total bacterial count (TBC), and bulk milk standard plate count (SPC) and to measure the repeatability of bulk milk culturing. On 53 Dutch dairy goat farms,

  19. It takes two—coincidence coding within the dual olfactory pathway of the honeybee

    OpenAIRE

    Brill, Martin F.; Meyer, Anneke; Rössler, Wolfgang

    2015-01-01

    To rapidly process biologically relevant stimuli, sensory systems have developed a broad variety of coding mechanisms like parallel processing and coincidence detection. Parallel processing (e.g., in the visual system), increases both computational capacity and processing speed by simultaneously coding different aspects of the same stimulus. Coincidence detection is an efficient way to integrate information from different sources. Coincidence has been shown to promote associative learning and...

  20. Quantifying radionuclide signatures from a γ–γ coincidence system

    International Nuclear Information System (INIS)

    Britton, Richard; Jackson, Mark J.; Davies, Ashley V.

    2015-01-01

    A method for quantifying gamma coincidence signatures has been developed, and tested in conjunction with a high-efficiency multi-detector system to quickly identify trace amounts of radioactive material. The γ–γ system utilises fully digital electronics and list-mode acquisition to time–stamp each event, allowing coincidence matrices to be easily produced alongside typical ‘singles’ spectra. To quantify the coincidence signatures a software package has been developed to calculate efficiency and cascade summing corrected branching ratios. This utilises ENSDF records as an input, and can be fully automated, allowing the user to quickly and easily create/update a coincidence library that contains all possible γ and conversion electron cascades, associated cascade emission probabilities, and true-coincidence summing corrected γ cascade detection probabilities. It is also fully searchable by energy, nuclide, coincidence pair, γ multiplicity, cascade probability and half-life of the cascade. The probabilities calculated were tested using measurements performed on the γ–γ system, and found to provide accurate results for the nuclides investigated. Given the flexibility of the method, (it only relies on evaluated nuclear data, and accurate efficiency characterisations), the software can now be utilised for a variety of systems, quickly and easily calculating coincidence signature probabilities. - Highlights: • Monte-Carlo based software developed to easily create/update a coincidence signal library for environmental radionuclides. • Coincidence library utilised to accurately quantify gamma coincidence signatures. • All coincidence signature probabilities are corrected for cascade summing, conversion electron emission and pair production. • Key CTBTO relevant radionuclides have been tested to verify the calculated correction factors. • Accurately quantifying coincidence signals during routine analysis will allow dramatically improved detection

  1. Differential coincidence circuit in the 10-10 second region (1960)

    International Nuclear Information System (INIS)

    Van Zurk, R.; Grenoble-1 Univ., 38; Commissariat a l'Energie Atomique, Saclay

    1960-01-01

    A coincidence circuit of low resolution time using the differential coincidence Bay principle is described. It uses three 6BN6 tubes ordered to chronotron structure. Results with Radiotechnique 56 AVP photomultipliers and for 60 Co γ-γ coincidences are 4,6.10 -10 s (full width at half maximum) if the efficiency is ε = 40 per cent and also 7,2.10 -10 s if ε = 85 per cent. (author) [fr

  2. Nearest neighbors by neighborhood counting.

    Science.gov (United States)

    Wang, Hui

    2006-06-01

    Finding nearest neighbors is a general idea that underlies many artificial intelligence tasks, including machine learning, data mining, natural language understanding, and information retrieval. This idea is explicitly used in the k-nearest neighbors algorithm (kNN), a popular classification method. In this paper, this idea is adopted in the development of a general methodology, neighborhood counting, for devising similarity functions. We turn our focus from neighbors to neighborhoods, a region in the data space covering the data point in question. To measure the similarity between two data points, we consider all neighborhoods that cover both data points. We propose to use the number of such neighborhoods as a measure of similarity. Neighborhood can be defined for different types of data in different ways. Here, we consider one definition of neighborhood for multivariate data and derive a formula for such similarity, called neighborhood counting measure or NCM. NCM was tested experimentally in the framework of kNN. Experiments show that NCM is generally comparable to VDM and its variants, the state-of-the-art distance functions for multivariate data, and, at the same time, is consistently better for relatively large k values. Additionally, NCM consistently outperforms HEOM (a mixture of Euclidean and Hamming distances), the "standard" and most widely used distance function for multivariate data. NCM has a computational complexity in the same order as the standard Euclidean distance function and NCM is task independent and works for numerical and categorical data in a conceptually uniform way. The neighborhood counting methodology is proven sound for multivariate data experimentally. We hope it will work for other types of data.

  3. Applied physics

    International Nuclear Information System (INIS)

    Anon.

    1980-01-01

    The Physics Division research program that is dedicated primarily to applied research goals involves the interaction of energetic particles with solids. This applied research is carried out in conjunction with the basic research studies from which it evolved

  4. Examining secular trend  and seasonality in count data using dynamic generalized linear modelling

    DEFF Research Database (Denmark)

    Lundbye-Christensen, Søren; Dethlefsen, Claus; Gorst-Rasmussen, Anders

    series regression model for Poisson counts. It differs in allowing the regression coefficients to vary gradually over time in a random fashion. Data  In the period January 1980 to 1999, 17,989 incidents of acute myocardial infarction were recorded in the county of Northern Jutland, Denmark. Records were......Aims  Time series of incidence counts often show secular trends and seasonal patterns. We present a model for incidence counts capable of handling a possible gradual change in growth rates and seasonal patterns, serial correlation and overdispersion. Methods  The model resembles an ordinary time...... updated daily. Results  The model with a seasonal pattern and an approximately linear trend was fitted to the data, and diagnostic plots indicate a good model fit. The analysis with the dynamic model revealed peaks coinciding with influenza epidemics. On average the peak-to-trough ratio is estimated...

  5. CalCOFI Egg Counts Positive Tows

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Fish egg counts and standardized counts for eggs captured in CalCOFI icthyoplankton nets (primarily vertical [Calvet or Pairovet], oblique [bongo or ring nets], and...

  6. CalCOFI Larvae Counts Positive Tows

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Fish larvae counts and standardized counts for eggs captured in CalCOFI icthyoplankton nets (primarily vertical [Calvet or Pairovet], oblique [bongo or ring nets],...

  7. Alaska Steller Sea Lion Pup Count Database

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This database contains counts of Steller sea lion pups on rookeries in Alaska made between 1961 and 2015. Pup counts are conducted in late June-July. Pups are...

  8. Obesidade e asma: associação ou coincidência? Obesity and asthma: association or coincidence?

    Directory of Open Access Journals (Sweden)

    Daniella Fernandes Camilo

    2010-02-01

    Full Text Available OBJETIVO: A asma e a obesidade estão entre as maiores causas de morbidade na infância e adolescência. A obesidade precoce aumenta as chances de doenças crônicas degenerativas no adulto. Embora a concomitância de ambas as situações clínicas vem sendo demonstrada em vários estudos, os mecanismos intrínsecos dessa associação ainda são pouco conhecidos. Portanto, o objetivo deste artigo foi revisar os principais trabalhos sobre a associação de obesidade e asma e verificar se existe relação de causa e efeito entre ambas. FONTES DOS DADOS: Revisão sistemática baseada em bases de dados indexadas MEDLINE (PubMed e SciELO. Foram revisados artigos originais (transversal, caso-controle e prospectivo e meta-análises publicados no período de janeiro de 1998 a janeiro de 2008. Foram pesquisados estudos divulgados em língua inglesa, espanhola e portuguesa. SÍNTESE DOS DADOS: Embora existam muitos estudos sobre as crescentes prevalências da asma e da obesidade, poucos estabelecem relações de causa e efeito entre ambas. Os mecanismos fisiopatológicos e os fatores envolvidos nesse processo ainda são pouco conhecidos. CONCLUSÃO: O rigor metodológico em estudos futuros deverá buscar respostas para melhor entender se existe associação entre asma e obesidade, ou se a relação entre ambas as doenças é coincidência.OBJECTIVE: Asthma and obesity are among the major causes of morbidity in childhood and adolescence. Early obesity increases the chances of chronic degenerative diseases in adults. Although the concomitance or both clinical situations are being demonstrated in various studies, the intrinsic mechanisms of this association are still very little known. Therefore, the objective of this article was to review the main studies on the association of obesity and asthma and check if there is a cause-effect relation between them. SOURCES: Systematic review based on indexed data bases MEDLINE (PubMed and SciELO. Original articles

  9. Bioassay method for Uranium in urine by Delay Neutron counting

    International Nuclear Information System (INIS)

    Suratman; Purwanto; Sukarman-Aminjoyo

    1996-01-01

    A bioassay method for uranium in urine by neutron counting has been studied. The aim of this research is to obtain a bioassay method for uranium in urine which is used for the determination of internal dose of radiation workers. The bioassay was applied to the artificially uranium contaminated urine. The weight of the contaminant was varied. The uranium in the urine was irradiated in the Kartini reactor core, through pneumatic system. The delayed neutron was counted by BF3 neutron counter. Recovery of the bioassay was between 69.8-88.8 %, standard deviation was less than 10 % and the minimum detection was 0.387 μg

  10. Design and test of 4πβ-γ coincidence measurement device based on DSP technology

    International Nuclear Information System (INIS)

    Zeng Herong; Feng Qijie; Leng Jun; Qian Dazhi; Bai Lixin; Zhang Yiyun

    2012-01-01

    The paper illustrates the hardware and software of the 4πβ-γ coincidence measurement device based on DSP technology in detail. In such device, the single-channel analyzer, gate generator, coincidence circuit and scalar in the traditional coincidence measurement device are replaced by the digital coincidence acquirer which is researched and manufactured by ourselves. Doing so, the measurement efficiency will be respectively improved, and the hardware cost will be lowered. The comparison experiment shows that the design of such device is a success. (authors)

  11. Studies on the true coincidence correction in measuring filter samples by gamma spectrometry

    CERN Document Server

    Lian Qi; Chang Yong Fu; Xia Bing

    2002-01-01

    The true coincidence correction in measuring filter samples has been studied by high efficiency HPGe gamma detectors. The true coincidence correction for a specific three excited levels de-excitation case has been analyzed, and the typical analytical expressions of true coincidence correction factors have been given. According to the measured relative efficiency on the detector surface with 8 'single' energy gamma emitters and efficiency of filter samples, the peak and total efficiency surfaces are fitted. The true coincidence correction factors of sup 6 sup 0 Co and sup 1 sup 5 sup 2 Eu calculated by the efficiency surfaces agree well with experimental results

  12. The development and application of a coincidence measurement apparatus with micro-computer system

    International Nuclear Information System (INIS)

    Du Hongshan; Zhou Youpu; Gao Junlin; Qin Deming; Cao Yunzheng; Zhao Shiping

    1987-01-01

    A coincidence measurement apparatus with micro-computer system is developed. Automatic data acquisition and processing are achieved. Results of its application for radioactive measurement are satisfactory

  13. SPERM COUNT DISTRIBUTIONS IN FERTILE MEN

    Science.gov (United States)

    Sperm concentration and count are often used as indicators of environmental impacts on male reproductive health. Existing clinical databases may be biased towards subfertile men with low sperm counts and less is known about expected sperm count distributions in cohorts of fertil...

  14. Platelet counting using the Coulter electronic counter.

    Science.gov (United States)

    Eggleton, M J; Sharp, A A

    1963-03-01

    A method for counting platelets in dilutions of platelet-rich plasm using the Coulter electronic counter is described.(1) The results obtained show that such platelet counts are at least as accurate as the best methods of visual counting. The various technical difficulties encountered are discussed.

  15. Count-doubling time safety circuit

    International Nuclear Information System (INIS)

    Keefe, D.J.; McDowell, W.P.; Rusch, G.K.

    1981-01-01

    There is provided a nuclear reactor count-factor-increase time monitoring circuit which includes a pulse-type neutron detector, and means for counting the number of detected pulses during specific time periods. Counts are compared and the comparison is utilized to develop a reactor scram signal, if necessary

  16. Count-doubling time safety circuit

    Science.gov (United States)

    Rusch, Gordon K.; Keefe, Donald J.; McDowell, William P.

    1981-01-01

    There is provided a nuclear reactor count-factor-increase time monitoring circuit which includes a pulse-type neutron detector, and means for counting the number of detected pulses during specific time periods. Counts are compared and the comparison is utilized to develop a reactor scram signal, if necessary.

  17. DC KIDS COUNT e-Databook Indicators

    Science.gov (United States)

    DC Action for Children, 2012

    2012-01-01

    This report presents indicators that are included in DC Action for Children's 2012 KIDS COUNT e-databook, their definitions and sources and the rationale for their selection. The indicators for DC KIDS COUNT represent a mix of traditional KIDS COUNT indicators of child well-being, such as the number of children living in poverty, and indicators of…

  18. How much do women count if they not counted?

    Directory of Open Access Journals (Sweden)

    Federica Taddia

    2006-01-01

    Full Text Available The condition of women throughout the world is marked by countless injustices and violations of the most fundamental rights established by the Universal Declaration of human rights and every culture is potentially prone to commit discrimination against women in various forms. Women are worse fed, more exposed to physical violence, more exposed to diseases and less educated; they have less access to, or are excluded from, vocational training paths; they are the most vulnerable among prisoners of conscience, refugees and immigrants and the least considered within ethnic minorities; from their very childhood, women are humiliated, undernourished, sold, raped and killed; their work is generally less paid compared to men’s work and in some countries they are victims of forced marriages. Such condition is the result of old traditions that implicit gender-differentiated education has long promoted through cultural models based on theories, practices and policies marked by discrimination and structured differentially for men and women. Within these cultural models, the basic educational institutions have played and still play a major role in perpetuating such traditions. Nevertheless, if we want to overcome inequalities and provide women with empowerment, we have to start right from the educational institutions and in particular from school, through the adoption of an intercultural approach to education: an approach based on active pedagogy and on methods of analysis, exchange and enhancement typical of socio-educational animation. The intercultural approach to education is attentive to promote the realisation of each individual and the dignity and right of everyone to express himself/herself in his/her own way. Such an approach will give women the opportunity to become actual agents of collective change and to get the strength and wellbeing necessary to count and be counted as human beings entitled to freedom and equality, and to have access to all

  19. Low-level flow counting of liquid chromatography column eluates

    International Nuclear Information System (INIS)

    Harding, N.G.L.; Farid, Y.; Stewart, M.J.

    1982-01-01

    The principal parameters which determine the operation of a high-resolution, high-sensitivity radioactive flow monitor are described: a) Sample preparation to ensure adequate recovery of radiolabelled sample, metabolites and internal standard. b) The instrument background count rate, when no sample or radiolabel is present in the flow cell, is a function of shielding and a reduction in noise obtained with a coincidence time below one microsecond. c) The minimum detectable amount of label depends upon the machine background, HPLC eluent and scintillator flow, whether or not packed flow cells are used, flow cell geometry, and the scintillator used. d) Three types of flow cell have been designed to cover the majority of HPLC and isotope applications. e) The performance of solid and liquid scintillators. It is shown that an instrument has been designed taking account of these parameters. The resulting design satisfies present high sensitivity counting requirements and maintains the resolution of current HPLC procedures when detection is by simultaneous flow radioassay and by optical methods. (orig.)

  20. Resonant count diagram and solar g mode oscillations

    International Nuclear Information System (INIS)

    Guenther, D.B.; Demarque, P.

    1984-01-01

    Evidence is provided to support the hypothesis that, because of the particular frequency separations of the solar g modes, resonant three-wave interactions stimulate only a selected few g modes. A resonant count diagram was obtained by plotting the total number of possible resonant three-wave interactions or a given beat frequency against the inverse of the beat frequency (the beat period), within a given frequency tolerance. The 1 = 1, 2, 3, 4 g modes calculated by Christensen-Dalsgaard, Gough and Morgan (1979) for a standard model of the Sun were used. The diagram has a significant peak at 160 minutes as well as other peaks at longer periods. The g modes that Delache and Scherrer (1983) tentatively identified from the Crimea-Stanford data were also plotted. These modes were found to correspond with the other peaks in the diagram. This coincidence between the observed g modes and the peaks in the resonant count diagram suggest that the observed g modes do owe their observability to resonant three-wave interactions

  1. Realisation of a {beta} spectrometer solenoidal and a double {beta} spectrometer at coincidence; Realisation d'un spectrometre {beta} solenoidal et d'un double spectrometre {beta} a coincidence

    Energy Technology Data Exchange (ETDEWEB)

    Moreau, J [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1955-06-15

    The two spectrometers have been achieved to tackle numerous problems of nuclear spectrometry. They possess different fields of application that complete themselves. The solenoidal spectrometer permits the determination of the energy limits of {beta} spectra and of their shape; it also permits the determination of the coefficients of internal conversion and reports {alpha}{sub K} / {alpha}{sub L} and it is especially efficient for the accurate energy levels of the {gamma} rays by photoelectric effect. The double coincidence spectrometer has been conceived to get a good efficiency in coincidence: indeed, the sum of the solid angles used for the {beta} and {gamma} emission is rather little lower to 4{pi} steradians. To get this efficiency, one should have sacrificed a little the resolution that is lower to the one obtained with the solenoidal spectrometer for a same brightness. Each of the elements of the double spectrometer can also be adapted to the study of angular correlations {beta}{gamma} and e{sup -}{gamma}. In this use, it is superior to the thin magnetic lens used up to here. The double spectrometer also permits the survey of the coincidences e{sup -}e{sup -}, e{sup -}{beta} of a equivalent way to a double lens; it can also be consider some adaptation for the survey of the angular correlations e{sup -}e{sup -}, e{sup -}{beta}. Finally, we applied the methods by simple spectrometry and by coincidence spectrometry, to the study of the radiances of the following radioelements: {sup 76}As (26 h), {sup 122}Sb (2,8 j), {sup 124}Sb (60 j), {sup 125}Sb (2,7 years). (M.B.) [French] Les deux spectrometres qui ont ete realises permettent d'aborder un grand nombre de problemes de spectrometrie nucleaire. Ils possedent des champs d'application tres differents qui se completent. Le spectrometre solenoidal permet la determination des energies limites des spectres {beta} et de leur forme; il permet aussi la determination des coefficients de conversion interne et des rapports

  2. Standard test method for nondestructive assay of nuclear material in scrap and waste by passive-Active neutron counting using 252Cf shuffler

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2008-01-01

    1.1 This test method covers the nondestructive assay of scrap and waste items for U, Pu, or both, using a 252Cf shuffler. Shuffler measurements have been applied to a variety of matrix materials in containers of up to several 100 L. Corrections are made for the effects of matrix material. Applications of this test method include measurements for safeguards, accountability, TRU, and U waste segregation, disposal, and process control purposes (1, 2, 3). 1.1.1 This test method uses passive neutron coincidence counting (4) to measure the 240Pu-effective mass. It has been used to assay items with total Pu contents between 0.03 g and 1000 g. It could be used to measure other spontaneously fissioning isotopes such as Cm and Cf. It specifically describes the approach used with shift register electronics; however, it can be adapted to other electronics. 1.1.2 This test method uses neutron irradiation with a moveable Cf source and counting of the delayed neutrons from the induced fissions to measure the 235U equiva...

  3. Counting statistics and loss corrections for the APS

    International Nuclear Information System (INIS)

    Lee, W.K.; Mills, D.M.

    1992-01-01

    It has been suggested that for timing experiments, it might be advantageous to arrange the bunches in the storage ring in an asymmetrical mode. In this paper, we determine the counting losses from pulsed x-ray sources from basic probabilistic arguments and from Poisson statistics. In particular the impact on single-photon counting losses of a variety of possible filling modes for the Advanced Photon Source (APS) is examined. For bunches of equal current, a loss of 10% occurs whenever the count rate exceeds 21% of the bunch repetition rate. This changes slightly when bunches containing unequal numbers of particles are considered. The results are applied to several common detector/electronics systems

  4. Counting statistics and loss corrections for the APS

    International Nuclear Information System (INIS)

    Lee, W.K.; Mills, D.M.

    1992-01-01

    It has been suggested that for timing experiments, it might be advantageous to arrange the bunches in the storage ring in an asymmetrical mode. In this paper, we determine the counting losses from pulsed x-ray sources from basic probabilistic arguments and from Poisson statistics. In particular the impact on single photon counting losses of a variety of possible filling modes for the Advanced Photon Source (APS) is examined. For bunches of equal current, a loss of 10% occurs whenever the count rate exceeds 21% of the bunch repetition rate. This changes slightly when bunches containing unequal numbers of particles are considered. The results are applied to several common detector/electronics systems

  5. Photon Counting Using Edge-Detection Algorithm

    Science.gov (United States)

    Gin, Jonathan W.; Nguyen, Danh H.; Farr, William H.

    2010-01-01

    New applications such as high-datarate, photon-starved, free-space optical communications require photon counting at flux rates into gigaphoton-per-second regimes coupled with subnanosecond timing accuracy. Current single-photon detectors that are capable of handling such operating conditions are designed in an array format and produce output pulses that span multiple sample times. In order to discern one pulse from another and not to overcount the number of incoming photons, a detection algorithm must be applied to the sampled detector output pulses. As flux rates increase, the ability to implement such a detection algorithm becomes difficult within a digital processor that may reside within a field-programmable gate array (FPGA). Systems have been developed and implemented to both characterize gigahertz bandwidth single-photon detectors, as well as process photon count signals at rates into gigaphotons per second in order to implement communications links at SCPPM (serial concatenated pulse position modulation) encoded data rates exceeding 100 megabits per second with efficiencies greater than two bits per detected photon. A hardware edge-detection algorithm and corresponding signal combining and deserialization hardware were developed to meet these requirements at sample rates up to 10 GHz. The photon discriminator deserializer hardware board accepts four inputs, which allows for the ability to take inputs from a quadphoton counting detector, to support requirements for optical tracking with a reduced number of hardware components. The four inputs are hardware leading-edge detected independently. After leading-edge detection, the resultant samples are ORed together prior to deserialization. The deserialization is performed to reduce the rate at which data is passed to a digital signal processor, perhaps residing within an FPGA. The hardware implements four separate analog inputs that are connected through RF connectors. Each analog input is fed to a high-speed 1

  6. Absolute standardization of {sup 65}Zn through anti-coincidence method 4πβ-γ; Padronização absoluta do {sup 65}Zn pelo método de anticoincidência 4πβ-γ

    Energy Technology Data Exchange (ETDEWEB)

    Santos, A.R.L.; Silva, C.J. da; Delgado, J.U.; Silva, R.L. da; Poledna, R.; Iwahara, A., E-mail: aleiras@ird.gov.br [Instituto de Radioproteção e Dosimetria (LNMRI/IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil); Tavares, D.Y.S. [Instituto de Engenharia Nuclear (IEN/CNEN-RJ), Rio de Janeiro, RJ (Brazil)

    2017-07-01

    The {sup 65}Zn solution was standardized using the absolute 4πβ(LS)-γ(NaI) anticoincidence counting method and beta efficiency extrapolation technique by the National Laboratory of Ionizing Radiation Metrology at the Institute of Radioprotection and Dosimetry (LNMRI/IRD). The result of the present standardization was consistent with the standardization previously performed by the coincidence counting method 4πβ(LS)-γ(NaI) in 2010. The combined uncertainty of the activity obtained was 0.37%, showing that the method is suitable for the standardization of {sup 65}Zn. (author)

  7. Single electron counting using a dual MCP assembly

    International Nuclear Information System (INIS)

    Yang, Yuzhen; Liu, Shulin; Zhao, Tianchi; Yan, Baojun; Wang, Peiliang; Yu, Yang; Lei, Xiangcui; Yang, Luping; Wen, Kaile; Qi, Ming

    2016-01-01

    The gain, pulse height resolution and peak-to-valley ratio of single electrons detected by using a Chevron configured Microchannel Plate (MCP) assembly are studied. The two MCPs are separated by a 280 µm gap and are biased by four electrodes. The purpose of the study is to determine the optimum bias voltage arrangements for single electron counting. By comparing the results of various bias voltage combinations, we conclude that good performance for the electron counting can be achieved by operating the MCP assembly in saturation mode. In addition, by applying a small reverse bias voltage across the gap while adjusting the bias voltages of the MCPs, optimum performance of electron counting can be obtained. - Highlights: • Dual MCPs assembly with four electrodes using different voltage combinations has been investigated for single electron counting. • Both the MCP voltages and the gap voltage can affect the gain, pulse height resolution and P/V ratio. • A high gain of the first stage MCP, a saturation mode of the second stage MCP and an appropriately reverse gap voltage can improve the resolution greatly. • The optimum voltage arrangements is significant for the design of MCP detectors in single electron counting applications.

  8. An automated approach for annual layer counting in ice cores

    Directory of Open Access Journals (Sweden)

    M. Winstrup

    2012-11-01

    Full Text Available A novel method for automated annual layer counting in seasonally-resolved paleoclimate records has been developed. It relies on algorithms from the statistical framework of hidden Markov models (HMMs, which originally was developed for use in machine speech recognition. The strength of the layer detection algorithm lies in the way it is able to imitate the manual procedures for annual layer counting, while being based on statistical criteria for annual layer identification. The most likely positions of multiple layer boundaries in a section of ice core data are determined simultaneously, and a probabilistic uncertainty estimate of the resulting layer count is provided, ensuring an objective treatment of ambiguous layers in the data. Furthermore, multiple data series can be incorporated and used simultaneously. In this study, the automated layer counting algorithm has been applied to two ice core records from Greenland: one displaying a distinct annual signal and one which is more challenging. The algorithm shows high skill in reproducing the results from manual layer counts, and the resulting timescale compares well to absolute-dated volcanic marker horizons where these exist.

  9. Radon counting statistics - a Monte Carlo investigation

    International Nuclear Information System (INIS)

    Scott, A.G.

    1996-01-01

    Radioactive decay is a Poisson process, and so the Coefficient of Variation (COV) of open-quotes nclose quotes counts of a single nuclide is usually estimated as 1/√n. This is only true if the count duration is much shorter than the half-life of the nuclide. At longer count durations, the COV is smaller than the Poisson estimate. Most radon measurement methods count the alpha decays of 222 Rn, plus the progeny 218 Po and 214 Po, and estimate the 222 Rn activity from the sum of the counts. At long count durations, the chain decay of these nuclides means that every 222 Rn decay must be followed by two other alpha decays. The total number of decays is open-quotes 3Nclose quotes, where N is the number of radon decays, and the true COV of the radon concentration estimate is 1/√(N), √3 larger than the Poisson total count estimate of 1/√3N. Most count periods are comparable to the half lives of the progeny, so the relationship between COV and count time is complex. A Monte-Carlo estimate of the ratio of true COV to Poisson estimate was carried out for a range of count periods from 1 min to 16 h and three common radon measurement methods: liquid scintillation, scintillation cell, and electrostatic precipitation of progeny. The Poisson approximation underestimates COV by less than 20% for count durations of less than 60 min

  10. Discrete calculus methods for counting

    CERN Document Server

    Mariconda, Carlo

    2016-01-01

    This book provides an introduction to combinatorics, finite calculus, formal series, recurrences, and approximations of sums. Readers will find not only coverage of the basic elements of the subjects but also deep insights into a range of less common topics rarely considered within a single book, such as counting with occupancy constraints, a clear distinction between algebraic and analytical properties of formal power series, an introduction to discrete dynamical systems with a thorough description of Sarkovskii’s theorem, symbolic calculus, and a complete description of the Euler-Maclaurin formulas and their applications. Although several books touch on one or more of these aspects, precious few cover all of them. The authors, both pure mathematicians, have attempted to develop methods that will allow the student to formulate a given problem in a precise mathematical framework. The aim is to equip readers with a sound strategy for classifying and solving problems by pursuing a mathematically rigorous yet ...

  11. Counting paths with Schur transitions

    Energy Technology Data Exchange (ETDEWEB)

    Díaz, Pablo [Department of Physics and Astronomy, University of Lethbridge, Lethbridge, Alberta, T1K 3M4 (Canada); Kemp, Garreth [Department of Physics, University of Johannesburg, P.O. Box 524, Auckland Park 2006 (South Africa); Véliz-Osorio, Alvaro, E-mail: aveliz@gmail.com [Mandelstam Institute for Theoretical Physics, University of the Witwatersrand, WITS 2050, Johannesburg (South Africa); School of Physics and Astronomy, Queen Mary, University of London, Mile End Road, London E1 4NS (United Kingdom)

    2016-10-15

    In this work we explore the structure of the branching graph of the unitary group using Schur transitions. We find that these transitions suggest a new combinatorial expression for counting paths in the branching graph. This formula, which is valid for any rank of the unitary group, reproduces known asymptotic results. We proceed to establish the general validity of this expression by a formal proof. The form of this equation strongly hints towards a quantum generalization. Thus, we introduce a notion of quantum relative dimension and subject it to the appropriate consistency tests. This new quantity finds its natural environment in the context of RCFTs and fractional statistics; where the already established notion of quantum dimension has proven to be of great physical importance.

  12. Mass counting of radioactivity samples

    International Nuclear Information System (INIS)

    Oesterlin, D.L.; Obrycki, R.F.

    1977-01-01

    A method and apparatus for concurrently counting a plurality of radioactive samples is claimed. The position sensitive circuitry of a scintillation camera is employed to sort electrical pulses resulting from scintillations according to the geometrical locations of scintillations causing those pulses. A scintillation means, in the form of a scintillating crystal material or a liquid scintillator, is positioned proximate to an array of radioactive samples. Improvement in the accuracy of pulse classification may be obtained by employing collimating means. If a plurality of scintillation crystals are employed to measure the iodine-125 content of samples, a method and means are provided for correcting for variations in crystal light transmission properties, sample volume, and sample container radiation absorption. 2 claims, 7 drawing figures

  13. New technique for determination of long-lived radioisotopes, Iodine-129, using multiparameter coincidence spectrometry

    International Nuclear Information System (INIS)

    Hatsukawa, Yuichi; Oshima, Masumi; Toh, Yosuke; Shinohara, Nobuo; Kushita, Kosuke; Ueno, Takashi

    2003-01-01

    Multiparameter coincidence γ-ray spectrometry based on g-g coincidence is widely used in the field of nuclear structure studies, and has produced many successful results. In this study, feasibility of the method for neutron activation analysis of long lived iodine isotope, 129 I, was investigated. (author)

  14. It Takes Two – Coincidence coding within the dual olfactory pathway of the honeybee

    Directory of Open Access Journals (Sweden)

    Martin F. Brill

    2015-07-01

    Full Text Available To rapidly process biologically relevant stimuli, sensory systems have developed a broad variety of coding mechanisms like parallel processing and coincidence detection. Parallel processing (e.g. in the visual system, increases both computational capacity and processing speed by simultaneously coding different aspects of the same stimulus. Coincidence detection is an efficient way to integrateinformation from different sources. Coincidence has been shown to promote associative learning and memory or stimulus feature detection (e.g. in auditory delay lines. Within the dual olfactory pathway of the honeybee both of these mechanisms might be implemented by uniglomerular projection neurons (PNs that transfer information from the primary olfactory centers, the antennal lobe (AL, to a multimodal integration center, the mushroom body (MB. PNs from anatomically distinct tracts respond to the same stimulus space, but have different physiological properties, characteristics that are prerequisites for parallel processing of different stimulus aspects. However, the PN pathways also display mirror-imaged like anatomical trajectories that resemble neuronal coincidence detectors as known from auditory delay lines. To investigate temporal processing of olfactory information, we recorded PN odor responses simultaneously from both tracts and measured coincident activity of PNs within and between tracts. Our results show that coincidence levels are different within each of the two tracts. Coincidence also occurs between tracts, but to a minor extent compared to coincidence within tracts. Taken together our findings support the relevance of spike timing in coding of olfactory information (temporal code.

  15. It takes two-coincidence coding within the dual olfactory pathway of the honeybee.

    Science.gov (United States)

    Brill, Martin F; Meyer, Anneke; Rössler, Wolfgang

    2015-01-01

    To rapidly process biologically relevant stimuli, sensory systems have developed a broad variety of coding mechanisms like parallel processing and coincidence detection. Parallel processing (e.g., in the visual system), increases both computational capacity and processing speed by simultaneously coding different aspects of the same stimulus. Coincidence detection is an efficient way to integrate information from different sources. Coincidence has been shown to promote associative learning and memory or stimulus feature detection (e.g., in auditory delay lines). Within the dual olfactory pathway of the honeybee both of these mechanisms might be implemented by uniglomerular projection neurons (PNs) that transfer information from the primary olfactory centers, the antennal lobe (AL), to a multimodal integration center, the mushroom body (MB). PNs from anatomically distinct tracts respond to the same stimulus space, but have different physiological properties, characteristics that are prerequisites for parallel processing of different stimulus aspects. However, the PN pathways also display mirror-imaged like anatomical trajectories that resemble neuronal coincidence detectors as known from auditory delay lines. To investigate temporal processing of olfactory information, we recorded PN odor responses simultaneously from both tracts and measured coincident activity of PNs within and between tracts. Our results show that coincidence levels are different within each of the two tracts. Coincidence also occurs between tracts, but to a minor extent compared to coincidence within tracts. Taken together our findings support the relevance of spike timing in coding of olfactory information (temporal code).

  16. Coincidence imaging of polyatomic molecules via laser-induced Coulomb explosion

    International Nuclear Information System (INIS)

    Gagnon, J; Corkum, P B; Bhardwaj, V R; Lee, Kevin F; Rayner, D M

    2008-01-01

    We extend laser-induced Coulomb explosion imaging to retrieve the structure of the five-atom dichloromethane (CH 2 Cl 2 ) molecule by developing coincidence imaging and geometry optimization techniques. By detecting all five atoms in coincidence, we show that, from the measured velocity vectors, the geometry of the molecules can be reconstructed.

  17. A new apparatus for electron-ion multiple coincidence momentum imaging spectroscopy

    International Nuclear Information System (INIS)

    Morishita, Y.; Kato, M.; Pruemper, G.; Liu, X.-J.; Lischke, T.; Ueda, K.; Tamenori, Y.; Oura, M.; Yamaoka, H.; Suzuki, I.H.; Saito, N.

    2006-01-01

    We have developed a new experimental apparatus for the electron-ion multiple coincidence momentum imaging spectroscopy in order to obtain the angular distributions of vibration-resolved photoelectrons from molecules fixed in space. The apparatus consists of a four-stage molecular supersonic jet and a spectrometer analyzing three-dimensional momenta of fragment ions and electrons in coincidence

  18. Dissociative photoionization of the NO molecule studied by photoelectron-photon coincidence technique

    International Nuclear Information System (INIS)

    Kivimaeki, A.; Alvarez-Ruiz, J.; Coreno, M.; Simone, M. de; Moise, A.; Partanen, L.; Richter, R.; Stankiewicz, M.

    2010-01-01

    Low-energy photoelectron-vacuum ultraviolet (VUV) photon coincidences have been measured using synchrotron radiation excitation in the inner-valence region of the nitric oxide molecule. The capabilities of the coincidence set-up were demonstrated by detecting the 2s -1 → 2p -1 radiative transitions in coincidence with the 2s photoelectron emission in Ne. In NO, the observed coincidence events are attributed to dissociative photoionization with excitation, whereby photoelectron emission is followed by fragmentation of excited NO + ions into O + + N* or N + + O* and VUV emission from an excited neutral fragment. The highest coincidence rate occurs with the opening of ionization channels which are due to correlation satellites of the 3σ photoionization. The decay time of VUV photon emission was also measured, implying that specific excited states of N atoms contribute significantly to observed VUV emission.

  19. Operation voltage of the counting system of nuclear traces in solids

    International Nuclear Information System (INIS)

    Garcia, M.L.; Quirino, L.L.; Mireles, F.; Davila, J.I.; Pinedo, J.L.; Lugo, J.F.; Vadillo, V.E.

    2002-01-01

    The semi-automatic counting system based on electric spark and used for traces reading in solid state detectors is evaluated for obtaining its counting voltage and also the breaking voltage of material. In the treatment of the solid state detectors it is continued the NTD methodology for concluding with the individual counting of the films, whose graphics offer the existing relationship among the applied voltage and the traces number. From each film a counting and breaking voltages are obtained. Finally, an average voltage of all them is estimated. (Author)

  20. Generating ActiGraph counts from raw acceleration recorded by an alternative monitor

    DEFF Research Database (Denmark)

    Brønd, Jan Christian; Andersen, Lars Bo; Arvidsson, Daniel

    2017-01-01

    Introduction: Raw acceleration data collected by the ActiGraph accelerometer is aggregated using a proprietary method into arbitrary physical activity intensity units called counts, which has been extensively calibrated and validated against energy expenditure. Generating ActiGraph counts from any...... second across all rotational frequencies compared to the original ActiGraph method. Applying the aggregation method to the 24-hour free-living recordings resulted in an epoch level bias ranging from -16.2 to 0.9 counts per 10 second, a relative difference in the averaged physical activity (counts per...

  1. Applied Electromagnetics

    Energy Technology Data Exchange (ETDEWEB)

    Yamashita, H; Marinova, I; Cingoski, V [eds.

    2002-07-01

    These proceedings contain papers relating to the 3rd Japanese-Bulgarian-Macedonian Joint Seminar on Applied Electromagnetics. Included are the following groups: Numerical Methods I; Electrical and Mechanical System Analysis and Simulations; Inverse Problems and Optimizations; Software Methodology; Numerical Methods II; Applied Electromagnetics.

  2. Applied Electromagnetics

    International Nuclear Information System (INIS)

    Yamashita, H.; Marinova, I.; Cingoski, V.

    2002-01-01

    These proceedings contain papers relating to the 3rd Japanese-Bulgarian-Macedonian Joint Seminar on Applied Electromagnetics. Included are the following groups: Numerical Methods I; Electrical and Mechanical System Analysis and Simulations; Inverse Problems and Optimizations; Software Methodology; Numerical Methods II; Applied Electromagnetics

  3. Differential coincidence circuit in the 10{sup -10} second region (1960); Circuit de coincidence differentiel dans le domaine de 10{sup -10} seconde (1960)

    Energy Technology Data Exchange (ETDEWEB)

    Van Zurk, R [Commissariat a l' Energie Atomique, Lab. de Physique Nucleaire, Grenoble (France).Centre d' Etudes Nucleaires; [Grenoble-1 Univ., 38 (France); [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1960-07-01

    A coincidence circuit of low resolution time using the differential coincidence Bay principle is described. It uses three 6BN6 tubes ordered to chronotron structure. Results with Radiotechnique 56 AVP photomultipliers and for {sup 60}Co {gamma}-{gamma} coincidences are 4,6.10{sup -10} s (full width at half maximum) if the efficiency is {epsilon} = 40 per cent and also 7,2.10{sup -10} s if {epsilon} = 85 per cent. (author) [French] Un circuit de coincidence differentiel du type de Bay, utilise en selecteur en temps a canal mobile, a ete construit pour la mesure des periodes {gamma} et des periodes d'annihilation du positon dans differents materiaux. Il comporte trois tubes 6BN6 disposes en structure chronotron. On a utilise les nouveaux photomultiplicateurs 56 AVP avec scintillateur plastique. Avec les coincidences {gamma}-{gamma} du {sup 60}Co, on obtient 2T 4,6.10{sup -10} s avec une efficacite de 40 pour cent et 2T = 7,2.10{sup -10} s avec une efficacite de 85 pour cent. (auteur)

  4. Investigation on Carbohydrate Counting Method in Type 1 Diabetic Patients

    Directory of Open Access Journals (Sweden)

    Osman Son

    2014-01-01

    Full Text Available Objective. The results from Diabetes Control and Complications Trial (DCCT have propounded the importance of the approach of treatment by medical nutrition when treating diabetes mellitus (DM. During this study, we tried to inquire carbohydrate (Kh count method’s positive effects on the type 1 DM treatment’s success as well as on the life quality of the patients. Methods. 22 of 37 type 1 DM patients who applied to Eskişehir Osmangazi University, Faculty of Medicine Hospital, Department of Endocrinology and Metabolism, had been treated by Kh count method and 15 of them are treated by multiple dosage intensive insulin treatment with applying standard diabetic diet as a control group and both of groups were under close follow-up for 6 months. Required approval was taken from the Ethical Committee of Eskişehir Osmangazi University, Medical Faculty, as well as informed consent from the patients. The body weight of patients who are treated by carbohydrate count method and multiple dosage intensive insulin treatment during the study beginning and after 6-month term, body mass index, and body compositions are analyzed. A short life quality and medical research survey applied. At statistical analysis, t-test, chi-squared test, and Mann-Whitney U test were used. Results. There had been no significant change determined at glycemic control indicators between the Kh counting group and the standard diabetic diet and multiple dosage insulin treatment group in our study. Conclusion. As a result, Kh counting method which offers a flexible nutrition plan to diabetic individuals is a functional method.

  5. The coincidence problem in holographic f(R) gravity

    Energy Technology Data Exchange (ETDEWEB)

    Bisabr, Yousef, E-mail: y-bisabr@srttu.edu [Department of Physics, Shahid Rajaee Teacher Training University, Lavizan, Tehran 16788 (Iran, Islamic Republic of)

    2011-09-15

    It is well known that f(R) gravity models formulated in the Einstein conformal frame are equivalent to Einstein gravity together with a minimally coupled scalar field. In this case, the scalar field couples with the matter sector and the coupling term is given by the conformal factor. We apply the holographic principle to such interacting models. In a spatially flat universe, we show that the Einstein frame representation of f(R) models leads to a constant ratio of energy densities of dark matter to dark energy.

  6. Quality control methods in accelerometer data processing: identifying extreme counts.

    Directory of Open Access Journals (Sweden)

    Carly Rich

    Full Text Available Accelerometers are designed to measure plausible human activity, however extremely high count values (EHCV have been recorded in large-scale studies. Using population data, we develop methodological principles for establishing an EHCV threshold, propose a threshold to define EHCV in the ActiGraph GT1M, determine occurrences of EHCV in a large-scale study, identify device-specific error values, and investigate the influence of varying EHCV thresholds on daily vigorous PA (VPA.We estimated quantiles to analyse the distribution of all accelerometer positive count values obtained from 9005 seven-year old children participating in the UK Millennium Cohort Study. A threshold to identify EHCV was derived by differentiating the quantile function. Data were screened for device-specific error count values and EHCV, and a sensitivity analysis conducted to compare daily VPA estimates using three approaches to accounting for EHCV.Using our proposed threshold of ≥ 11,715 counts/minute to identify EHCV, we found that only 0.7% of all non-zero counts measured in MCS children were EHCV; in 99.7% of these children, EHCV comprised < 1% of total non-zero counts. Only 11 MCS children (0.12% of sample returned accelerometers that contained negative counts; out of 237 such values, 211 counts were equal to -32,768 in one child. The medians of daily minutes spent in VPA obtained without excluding EHCV, and when using a higher threshold (≥19,442 counts/minute were, respectively, 6.2% and 4.6% higher than when using our threshold (6.5 minutes; p<0.0001.Quality control processes should be undertaken during accelerometer fieldwork and prior to analysing data to identify monitors recording error values and EHCV. The proposed threshold will improve the validity of VPA estimates in children's studies using the ActiGraph GT1M by ensuring only plausible data are analysed. These methods can be applied to define appropriate EHCV thresholds for different accelerometer models.

  7. Investigating the impact of LSO on the count rate of wholebody PET tomographs

    International Nuclear Information System (INIS)

    Douglas, J.L.; Moisan, C.; Rogers, J.G.

    1996-05-01

    We investigated the impact of using detectors made of lutetium oxyorthosilicate (LSO) on the count rate performances of wholebody PET tomographs. To that end, we used a single computational model that predicts the prompt and random contributions to the total event rate in septaless PET tomographs. Dead time factors at all stages of a typical event acquisition stream are calculated from specified values of their respective processing clock cycle. We validated our approach by fitting the true, random and multiple count rates measured with the ECAT-953B and the EXACT HR PLUS scanners for a standard 20 x 20 cm cylindrical phantom. We then investigated the implications of using position encoding detectors made of LSO in the EXACT HR PLUS scanner geometry. The results in indicate that only replacing BGO by the faster LSO incurs no appreciable change in the maximum noise-equivalent-count (NEC) rate of the scanner. However, one could realistically increase the NEC by a factor 2.5 using a 4 nsec coincidence window width with the detector processing front-end operating on a 128 nsec clock cycle. Further reducing the coincidence window width to 600 psec and the front-end clock cycle to 64 nsec leads to an increase of the NEC by a factor 7.5. To sustain the operation of an HR Plus with these specifications, the saturation bandwidth of the data acquisition system would have to be increased to no more than 4.5 MHz. (authors)

  8. Development of a coincidence system for radio-nuclide standardization using surface barrier detectors

    International Nuclear Information System (INIS)

    Koskinas, M.F.

    1988-01-01

    A system for the standardization of alpha-gamma or electron-X radionuclide emitters has been developed in the present work. The system consists of one or two surface barrier detectors for alpha or electron detection which are coupled to thin-window NaI (T1) crystals suitable for low energy X or gamma ray detection. The performance of the system has been verified by means of the standardization of 241 Am, 137 Cs and 109 Cd solutions. The activity has been obtained using the extrapolation method applied to the 4Πα-γ and 2Πe c -X coincidence technique. The surface barrier detection efficiency was varied by placing absorbers over the radioactive sources or by changing the source to detector distance. The results were compared to those obtained using conventional absolute systems based on gas-flow and pressurized 4Π proportional counters, or using radioactive solutions standardized in international comparisons spondored by the Bureau International des Poids et Mesures. The expect and measured activities agree within the experimental uncertainties which were: 0.2 % for 241 Am, 0.7% for 137 Cs and 0.6% for 109 Cd. The ratio between the probabilities of (electron capture + internal conversion) and internal conversion for the K-shell of 109 Cd has been determined. The result is: 2.8883 ± 0.016. (author) [pt

  9. Estimation of coincidence and correlation in non-analogous Monte Carlo particle transport - 159

    International Nuclear Information System (INIS)

    Szieberth, M.; Leen Kloosterman, J.

    2010-01-01

    The conventional non-analogous Monte Carlo methods are optimized to preserve the mean value of the distributions and therefore they are not suited for non-Boltzmann problems like the estimation of coincidences or correlations. This paper presents a general method called history splitting for the non-analogous estimation of such quantities. The basic principle of the method is that a non-analogous particle history can be interpreted as a collection of analogous histories with different weights according to the probability of their realization. Calculations with a simple Monte Carlo program for a pulse-height-type estimator prove that the method is feasible and provides unbiased estimation. Different variance reduction techniques have been tried with the method and Russian roulette turned out to be ineffective in high multiplicity systems. An alternative history control method is applied instead. Simulation results of a Feynman-α measurement shows that even the reconstruction of the higher moments is possible with the history splitting method, which makes the simulation of neutron noise measurements feasible. (authors)

  10. Unbiased estimators of coincidence and correlation in non-analogous Monte Carlo particle transport

    International Nuclear Information System (INIS)

    Szieberth, M.; Kloosterman, J.L.

    2014-01-01

    Highlights: • The history splitting method was developed for non-Boltzmann Monte Carlo estimators. • The method allows variance reduction for pulse-height and higher moment estimators. • It works in highly multiplicative problems but Russian roulette has to be replaced. • Estimation of higher moments allows the simulation of neutron noise measurements. • Biased sampling of fission helps the effective simulation of neutron noise methods. - Abstract: The conventional non-analogous Monte Carlo methods are optimized to preserve the mean value of the distributions. Therefore, they are not suited to non-Boltzmann problems such as the estimation of coincidences or correlations. This paper presents a general method called history splitting for the non-analogous estimation of such quantities. The basic principle of the method is that a non-analogous particle history can be interpreted as a collection of analogous histories with different weights according to the probability of their realization. Calculations with a simple Monte Carlo program for a pulse-height-type estimator prove that the method is feasible and provides unbiased estimation. Different variance reduction techniques have been tried with the method and Russian roulette turned out to be ineffective in high multiplicity systems. An alternative history control method is applied instead. Simulation results of an auto-correlation (Rossi-α) measurement show that even the reconstruction of the higher moments is possible with the history splitting method, which makes the simulation of neutron noise measurements feasible

  11. Maximum entropy deconvolution of low count nuclear medicine images

    International Nuclear Information System (INIS)

    McGrath, D.M.

    1998-12-01

    Maximum entropy is applied to the problem of deconvolving nuclear medicine images, with special consideration for very low count data. The physics of the formation of scintigraphic images is described, illustrating the phenomena which degrade planar estimates of the tracer distribution. Various techniques which are used to restore these images are reviewed, outlining the relative merits of each. The development and theoretical justification of maximum entropy as an image processing technique is discussed. Maximum entropy is then applied to the problem of planar deconvolution, highlighting the question of the choice of error parameters for low count data. A novel iterative version of the algorithm is suggested which allows the errors to be estimated from the predicted Poisson mean values. This method is shown to produce the exact results predicted by combining Poisson statistics and a Bayesian interpretation of the maximum entropy approach. A facility for total count preservation has also been incorporated, leading to improved quantification. In order to evaluate this iterative maximum entropy technique, two comparable methods, Wiener filtering and a novel Bayesian maximum likelihood expectation maximisation technique, were implemented. The comparison of results obtained indicated that this maximum entropy approach may produce equivalent or better measures of image quality than the compared methods, depending upon the accuracy of the system model used. The novel Bayesian maximum likelihood expectation maximisation technique was shown to be preferable over many existing maximum a posteriori methods due to its simplicity of implementation. A single parameter is required to define the Bayesian prior, which suppresses noise in the solution and may reduce the processing time substantially. Finally, maximum entropy deconvolution was applied as a pre-processing step in single photon emission computed tomography reconstruction of low count data. Higher contrast results were

  12. Applied superconductivity

    CERN Document Server

    Newhouse, Vernon L

    1975-01-01

    Applied Superconductivity, Volume II, is part of a two-volume series on applied superconductivity. The first volume dealt with electronic applications and radiation detection, and contains a chapter on liquid helium refrigeration. The present volume discusses magnets, electromechanical applications, accelerators, and microwave and rf devices. The book opens with a chapter on high-field superconducting magnets, covering applications and magnet design. Subsequent chapters discuss superconductive machinery such as superconductive bearings and motors; rf superconducting devices; and future prospec

  13. The ionization quench factor in liquid-scintillation counting standardizations

    CERN Document Server

    Grau-Malonda, A

    1999-01-01

    We present a new detailed analysis of the ionization quench function Q(E) used in calculating the counting efficiency in liquid-scintillation counting (LSC), which shows that Q(0)=1, and permits one to derive Q(E) as a function of the electron energy and the parameter kB. The coefficients are tabulated by applying a new empirical formula of Q(E) for kB values in the range between 0.001 and 0.20 gMeV sup - sup 1 cm sup - sup 2. We demonstrate the convenience of applying sup 3 H and sup 5 sup 4 Mn for beta-ray and electron capture standardizations, respectively.

  14. Covariance methodology applied to 35S disintegration rate measurements by the CIEMAT/NIST method

    International Nuclear Information System (INIS)

    Koskinas, M.F.; Nascimento, T.S.; Yamazaki, I.M.; Dias, M.S.

    2014-01-01

    The Nuclear Metrology Laboratory (LMN) at IPEN is carrying out measurements in a LSC (Liquid Scintillation Counting system), applying the CIEMAT/NIST method. In this context 35 S is an important radionuclide for medical applications and it is difficult to be standardized by other primary methods due to low beta ray energy. The CIEMAT/NIST is a standard technique used by most metrology laboratories in order to improve accuracy and speed up beta emitter standardization. The focus of the present work was to apply the covariance methodology for determining the overall uncertainty in the 35 S disintegration rate. All partial uncertainties involved in the measurements were considered, taking into account all possible correlations between each pair of them. - Highlights: ► 35 S disintegration rate measured in Liquid Scintillator system using CIEMAT/NIST method. ► Covariance methodology applied to the overall uncertainty in the 35 S disintegration rate. ► Monte Carlo simulation was applied to determine 35 S activity in the 4πβ(PC)-γ coincidence system

  15. Tight bounds for the Pearle-Braunstein-Caves chained inequality without the fair-coincidence assumption

    Science.gov (United States)

    Jogenfors, Jonathan; Larsson, Jan-Åke

    2017-08-01

    In any Bell test, loopholes can cause issues in the interpretation of the results, since an apparent violation of the inequality may not correspond to a violation of local realism. An important example is the coincidence-time loophole that arises when detector settings might influence the time when detection will occur. This effect can be observed in many experiments where measurement outcomes are to be compared between remote stations because the interpretation of an ostensible Bell violation strongly depends on the method used to decide coincidence. The coincidence-time loophole has previously been studied for the Clauser-Horne-Shimony-Holt and Clauser-Horne inequalities, but recent experiments have shown the need for a generalization. Here, we study the generalized "chained" inequality by Pearle, Braunstein, and Caves (PBC) with N ≥2 settings per observer. This inequality has applications in, for instance, quantum key distribution where it has been used to reestablish security. In this paper we give the minimum coincidence probability for the PBC inequality for all N ≥2 and show that this bound is tight for a violation free of the fair-coincidence assumption. Thus, if an experiment has a coincidence probability exceeding the critical value derived here, the coincidence-time loophole is eliminated.

  16. Counting Zero: Rethinking Feminist Epistemologies

    Directory of Open Access Journals (Sweden)

    Xin Liu

    2017-10-01

    Full Text Available This article concerns feminist engagements with epistemologies. Feminist epistemologies have revealed and challenged the exclusions and denigrations at work in knowledge production processes. And yet, the emphasis on the partiality of knowledge and the non-innocence of any subject position also cast doubt on the possibility of feminist political communities. In view of this, it has been argued that the very parameter of epistemology poses limitations for feminism, for it leads to either political paralysis or prescriptive politics that in fact undoes the political of politics. From a different perspective, decolonial feminists argue for radical epistemic disobedience and delinking the move beyond the confines of Western systems of knowledge and its extractive knowledge economy. Nevertheless, the oppositional logic informs both feminist epistemologies and its critiques, which I argue is symptomatic of the epistemic habits of academic feminism. This article ends with a preliminary reconsideration of the question of origin through the figure of zero. It asks whether it might be possible to conceive of feminist epistemologies as performing the task of counting zero – accounting for origin, wholeness, and universality – that takes into account specificities without forfeiting coalition and claims to knowledge.

  17. Leveraging multiple datasets for deep leaf counting

    OpenAIRE

    Dobrescu, Andrei; Giuffrida, Mario Valerio; Tsaftaris, Sotirios A

    2017-01-01

    The number of leaves a plant has is one of the key traits (phenotypes) describing its development and growth. Here, we propose an automated, deep learning based approach for counting leaves in model rosette plants. While state-of-the-art results on leaf counting with deep learning methods have recently been reported, they obtain the count as a result of leaf segmentation and thus require per-leaf (instance) segmentation to train the models (a rather strong annotation). Instead, our method tre...

  18. Arraycount, an algorithm for automatic cell counting in microwell arrays

    OpenAIRE

    Kachouie, Nezamoddin N.; Kang, Lifeng; Khademhosseini, Ali

    2009-01-01

    Microscale technologies have emerged as a powerful tool for studying and manipulating biological systems and miniaturizing experiments. However, the lack of software complementing these techniques has made it difficult to apply them for many high-throughput experiments. This work establishes Arraycount, an approach to automatically count cells in microwell arrays. The procedure consists of fluorescent microscope imaging of cells that are seeded in microwells of a microarray system and then an...

  19. Chemical and colour quenching in liquid scintillation counting

    International Nuclear Information System (INIS)

    Scott G, P. E.; Grau M, A.

    1987-01-01

    Chemical and colour quenching for H-3 and C-14 was studied. The method includes spectral analysis of colouring agents; methyl red, (4'-dimethylamine-azobenzene 2-carboxylic acid) dimethyl yellow (4'-dimethylamine-azobenzene) and malachite green (methane, bis .(4-dimethyl aminophenyl) - (phenyl)). External standard channels ratio was applied for the liquid scintillation counting of samples. The introduction of an isolated external standard seems to be a strong tool for the correction of chemical and colour quenching curves. (Author) 12 refs

  20. Learning word vector representations based on acoustic counts

    OpenAIRE

    Ribeiro, Sam; Watts, Oliver; Yamagishi, Junichi

    2017-01-01

    This paper presents a simple count-based approach to learning word vector representations by leveraging statistics of cooccurrences between text and speech. This type of representation requires two discrete sequences of units defined across modalities. Two possible methods for the discretization of an acoustic signal are presented, which are then applied to fundamental frequency and energy contours of a transcribed corpus of speech, yielding a sequence of textual objects (e.g. words, syllable...

  1. Resonance ionization spectroscopy: Counting noble gas atoms

    International Nuclear Information System (INIS)

    Hurst, G.S.; Payne, M.G.; Chen, C.H.; Willis, R.D.; Lehmann, B.E.; Kramer, S.D.

    1981-01-01

    The purpose of this paper is to describe new work on the counting of noble gas atoms, using lasers for the selective ionization and detectors for counting individual particles (electrons or positive ions). When positive ions are counted, various kinds of mass analyzers (magnetic, quadrupole, or time-of-flight) can be incorporated to provide A selectivity. We show that a variety of interesting and important applications can be made with atom-counting techniques which are both atomic number (Z) and mass number (A) selective. (orig./FKS)

  2. Instrument limitation of accuracy of absolute measurement by method of 4π beta-gamma coincidence

    International Nuclear Information System (INIS)

    Plkh, J.

    1979-01-01

    Accuracy is discussed of determination of coincidence channels dead-time in 4π β-γ installation and determination of coincidence resolution time as well as conditions for determination and accuracy of these parameters. Conditions are considered under which these parameters have not been determined and there is wrong performance of the installation. Special attention was paid to the electronic circuit of the γ-channel. It has been shown that as a result of wrong performance of electronic circuit a new type of wrong coincidence appeared [ru

  3. Testing the Cosmic Coincidence Problem and the Nature of Dark Energy

    International Nuclear Information System (INIS)

    Dalal, Neal; Abazajian, Kevork; Jenkins, Elizabeth; Manohar, Aneesh V.

    2001-01-01

    Dark energy models which alter the relative scaling behavior of dark energy and matter could provide a natural solution to the cosmic coincidence problem -- why the densities of dark energy and dark matter are comparable today. A generalized class of dark energy models is introduced which allows noncanonical scaling of the ratio of dark matter and dark energy with the Robertson-Walker scale factor a(t) . We show that determining whether there is a coincidence problem, and the extent of cosmic coincidence, can be addressed by several forthcoming experiments

  4. Counting the cost of housing

    NARCIS (Netherlands)

    Michiel Ras; Evelien Eggink; Edwin van Gameren; Ingrid Ooms

    2006-01-01

    Original title: Uitgerekend wonen. The Dutch government exerts a great influence on the housing costs incurred by households. Tenants can apply for housing subsidy, while owner-occupiers can set their mortgage interest against their income tax. These measures have existed for a long time, but

  5. Whole-body counting 1990

    International Nuclear Information System (INIS)

    Strand, P.; Selnaes, T.D.

    1990-01-01

    In order to determine the doses from radiocesium in foods after the Chernobyl accident, four groups were chosen in 1987. Two groups, presumed to have a large consumption of food items with a high radiocesium content, were selected. These were Lapp reindeer breeders from central parts of Norway, and hunters a.o. from the municipality of Oeystre Slidre. Two other groups were randomly selected, one from the municipality of Sel, and one from Oslo. The persons in these two groups were presumed to have an average diet. The fall-out in Sel was fairly large (100 kBq/m 2 ), whereas in Oslo the fall-out level was low (2 kBq/m 2 ). The persons in each group were monitored once a year with whole-body counters, and in connection with these countings dietary surveys were preformed. In 1990 the Sel-group and the Lapps in central parts of Norway were followed. Average whole-body activity in each group is compared to earlier years's results, and an average yearly effective dose equivalent is computed. The Sel-group has an average whole-body activity of 2800 Bq for men, and 690 Bq for women. Compared to earlier years, there is a steady but slow decrease in whole-body activities. Yearly dose is calculated to 0.06 mSv for 1990. The Lapps in central parts of Norway have an average whole-body content of 23800 Bq for men and 13600 Bq for women. This results in an average yearly dose of 0.9 mSv for the individuals in the group. Compared to earlier years, the Lapp group show a decrease in whole-body contents since 1988. This decrease is larger among men than women. 5 refs., 8 figs., 6 tabs

  6. Applied mathematics

    CERN Document Server

    Logan, J David

    2013-01-01

    Praise for the Third Edition"Future mathematicians, scientists, and engineers should find the book to be an excellent introductory text for coursework or self-study as well as worth its shelf space for reference." -MAA Reviews Applied Mathematics, Fourth Edition is a thoroughly updated and revised edition on the applications of modeling and analyzing natural, social, and technological processes. The book covers a wide range of key topics in mathematical methods and modeling and highlights the connections between mathematics and the applied and nat

  7. Comparison of satellite reflectance algorithms for estimating chlorophyll-a in a temperate reservoir using coincident hyperspectral aircraft imagery and dense coincident surface observations

    Science.gov (United States)

    We analyzed 10 established and 4 new satellite reflectance algorithms for estimating chlorophyll-a (Chl-a) in a temperate reservoir in southwest Ohio using coincident hyperspectral aircraft imagery and dense water truth collected within one hour of image acquisition to develop si...

  8. Measurement of scintillation decay curves by a single photon counting technique

    International Nuclear Information System (INIS)

    Noguchi, Tsutomu

    1978-01-01

    An improved apparatus suitable for the measurement of spectroscopic scintillation decay curves has been developed by combination of a single photon counting technique and a delayed coincidence method. The time resolution of the apparatus is improved up to 1.16 nsec (FWHM), which is obtained from the resolution function of the system for very weak Cherenkov light flashes. Systematic measurement of scintillation decay curves is made for liquid and crystal scintillators including PPO-toluene, PBD-xylene, PPO-POPOP-toluene, anthracene and stilbene. (auth.)

  9. Single-photon counting in the 1550-nm wavelength region for quantum cryptography

    International Nuclear Information System (INIS)

    Park, Chul-Woo; Park, Jun-Bum; Park, Young-Soo; Lee, Seung-Hun; Shin, Hyun-Jun; Bae, Byung-Seong; Moon, Sung; Han, Sang-Kook

    2006-01-01

    In this paper, we report the measured performance of an InGaAs avalanche photodiode (APD) Module fabricated for single-photon counting. We measured the dark current noise, the after-pulse noise, and the quantum efficiency of the single- photon detector for different temperatures. We then examined our single-photon source and detection system by measuring the coincident probability. From our measurement, we observed that the after-pulse effect of the APD at temperatures below 105 .deg. C caused cascade noise build-up on the succeeding electrical signals.

  10. Applied Enzymology.

    Science.gov (United States)

    Manoharan, Asha; Dreisbach, Joseph H.

    1988-01-01

    Describes some examples of chemical and industrial applications of enzymes. Includes a background, a discussion of structure and reactivity, enzymes as therapeutic agents, enzyme replacement, enzymes used in diagnosis, industrial applications of enzymes, and immobilizing enzymes. Concludes that applied enzymology is an important factor in…

  11. X-ray fluorescence/Auger-electron coincidence spectroscopy of vacancy cascades in atomic argon

    International Nuclear Information System (INIS)

    Arp, U.

    1996-01-01

    Argon L 2.3 -M 2.3 M 2.3 Auger-electron spectra were measured in coincidence with Kα fluorescent x-rays in studies of Ar K-shell vacancy decays at several photon energies above the K-threshold and on the 1s-4p resonance in atomic argon. The complex spectra recorded by conventional electron spectroscopy are greatly simplified when recorded in coincidence with fluorescent x-rays, allowing a more detailed analysis of the vacancy cascade process. The resulting coincidence spectra are compared with Hartree-Fock calculations which include shake-up transitions in the resonant case. Small energy shifts of the coincidence electron spectra are attributed to post-collision interaction with 1s photoelectrons

  12. Reproduction of the coincidence effect in gamma ray spectrometry by using Monte Carlo method

    International Nuclear Information System (INIS)

    Park, S. H.; Kim, J. K.; Lee, S. H.

    2001-01-01

    Scintillation detector such as NaI(TI), or semiconductor detector, such as HPGe, are used for Measurement/Assessment of the radiation type and radiation activity. The measured energy spectrum are used for measuring the radiation type and activity. Corrections for true coincidence due to emit more than 2 photons at the same time and random coincidence due to measuring system when increasing of the radiation intensity. For accurate assessment, measurement with adequate measure system is performed, and corrections for coincidence are performed in the hardware aspect and software aspect. In general, there are limitations or difficulties in measurement of radiation assessment, computational simulation is instead used. In simulation, it has much advantages than measurement in technically, timely, and financially, it is widely used instead of measurement. In this study, the method to reproduce of the coincidence effect was proposed by using monte carlo method

  13. High proportion of smaller ranged hummingbird species coincides with ecological specialization across the Americas

    DEFF Research Database (Denmark)

    Sonne, Jesper; Martín González, Ana M.; Maruyama, Pietro K.

    2016-01-01

    Ecological communities that experience stable climate conditions have been speculated to preserve more specialized interspecific associations and have higher proportions of smaller ranged species (SRS). Thus, areas with disproportionally large numbers of SRS are expected to coincide geographicall...

  14. On the extension of (e,2e) theory to coincidence studies of ion-atom collisions

    International Nuclear Information System (INIS)

    Godunov, A.L.; Kampp, Marco; Sulik, B.; Walters, H.R.J.; Whelan, Colm T.

    2007-01-01

    The extension of (e,2e) theory to the coincidence studies of ion-atom collisions is considered. The simultaneous ionization of projectile and target is discussed and results are presented for transfer ionization

  15. Angular correlations of coincident electron-positron pairs in heavy ion collisions

    International Nuclear Information System (INIS)

    Graf, O.

    1988-10-01

    In the present thesis angular correlations of coincident electron-positron pairsnin heavy ion collisions are studied. It is meant as a contribution to the answer of fundamental questions in the quantum electrodynamics of strong fields. (orig./HSI) [de

  16. A data acquisition system for coincidence imaging using a conventional dual head gamma camera

    Science.gov (United States)

    Lewellen, T. K.; Miyaoka, R. S.; Jansen, F.; Kaplan, M. S.

    1997-06-01

    A low cost data acquisition system (DAS) was developed to acquire coincidence data from an unmodified General Electric Maxxus dual head scintillation camera. A high impedance pick-off circuit provides position and energy signals to the DAS without interfering with normal camera operation. The signals are pulse-clipped to reduce pileup effects. Coincidence is determined with fast timing signals derived from constant fraction discriminators. A charge-integrating FERA 16 channel ADC feeds position and energy data to two CAMAC FERA memories operated as ping-pong buffers. A Macintosh PowerPC running Labview controls the system and reads the CAMAC memories. A CAMAC 12-channel scaler records singles and coincidence rate data. The system dead-time is approximately 10% at a coincidence rate of 4.0 kHz.

  17. A data acquisition system for coincidence imaging using a conventional dual head gamma camera

    International Nuclear Information System (INIS)

    Lewellen, T.K.; Miyaoka, R.S.; Kaplan, M.S.

    1996-01-01

    A low cost data acquisition system (DAS) was developed to acquire coincidence data from an unmodified General Electric Maxxus dual head scintillation camera. A high impedance pick-off circuit provides position and energy signals to the DAS without interfering with normal camera operation. The signals are pulse-clipped to reduce pileup effects. Coincidence is determined with fast timing signals derived from constant fraction discriminators. A charge-integrating FERA 16 channel ADC feeds position and energy data to two CAMAC FERA memories operated as ping-pong buffers. A Macintosh PowerPC running Labview controls the system and reads the CAMAC memories. A CAMAC 12-channel scaler records singles and coincidence rate data. The system dead-time is approximately 10% at a coincidence rate of 4.0 kHz

  18. A Case Study Using CRA to Teach Students with Disabilities to Count Using Flexible Numbers: Applying Skip Counting to Multiplication

    Science.gov (United States)

    Gibbs, Anna S.; Hinton, Vanessa M.; Flores, Margaret M.

    2018-01-01

    Children who struggle in mathematics have a limited understanding of the foundational processes of mathematics. A lack of conceptual understanding causes students to fall behind as they progress through the core curriculum. Children at high risk for developing mathematics disabilities fail to gain numeracy knowledge. The purpose of this case study…

  19. Coincidence and covariance data acquisition in photoelectron and -ion spectroscopy. I. Formal theory

    Science.gov (United States)

    Mikosch, Jochen; Patchkovskii, Serguei

    2013-10-01

    We derive a formal theory of noisy Poisson processes with multiple outcomes. We obtain simple, compact expressions for the probability distribution function of arbitrarily complex composite events and its moments. We illustrate the utility of the theory by analyzing properties of coincidence and covariance photoelectron-photoion detection involving single-ionization events. The results and techniques introduced in this work are directly applicable to more general coincidence and covariance experiments, including multiple ionization and multiple-ion fragmentation pathways.

  20. Multidimensional coincidence point results for generalized $(\\psi ,\\theta ,\\varphi$-contraction on ordered metric spaces

    Directory of Open Access Journals (Sweden)

    Bhavana Deshpande

    2017-11-01

    Full Text Available The main objective of this research article is to establish some coincidence point theorem for $g$-non-decreasing mappings under generalized $(\\psi ,\\theta ,\\varphi $-contraction on a partially ordered metric space. Furthermore, we show how multidimensional results can be seen as a simple consequences of our unidimensional coincidence point theorem. Our results modify, improve, sharpen, enrich and generalize various known results.