WorldWideScience

Sample records for coherent optical photons

  1. Coherent conversion between optical and microwave photons in Rydberg gases

    CERN Document Server

    Kiffner, Martin; Kaczmarek, Krzysztof T; Jaksch, Dieter; Nunn, Joshua

    2016-01-01

    Quantum information encoded in optical photons can be transmitted over long distances with very high information density, and suffers from negligible thermal noise at room temperature. On the other hand, microwave photons at cryogenic temperatures can be confined in high quality resonators and strongly coupled to solid-state qubits, providing a quantum bus to connect qubits and a route to deterministic photonic non-linearities. The coherent interconversion of microwave and optical photons has therefore recently emerged as a highly desirable capability that would enable freely-scalable networks of optically-linked qubits, or large-scale photonic information processing with multi-photon interactions mediated by microwaves. Here, we propose a route to efficient and coherent microwave-optical conversion based on frequency mixing in Rydberg atoms. The interaction requires no microfabricated components or cavities, and is tunable, broadband, and both spatially and spectrally multimode.

  2. Quantum-optical coherence tomography with collinear entangled photons.

    Science.gov (United States)

    Lopez-Mago, Dorilian; Novotny, Lukas

    2012-10-01

    Quantum-optical coherence tomography (QOCT) combines the principles of classical OCT with the correlation properties of entangled photon pairs [Phys. Rev. A 65, 053817 (2002)]. The standard QOCT configuration is based on the Hong-Ou-Mandel interferometer, which uses entangled photons propagating in separate interferometer arms. This noncollinear configuration imposes practical limitations, e.g., misalignment due to drift and low signal-to-noise. Here, we introduce and implement QOCT based on collinear entangled photons. It makes use of a two-photon Michelson interferometer and offers several advantages, such as simplicity, robustness, and adaptability.

  3. Optical phase estimation via coherent state and displaced photon counting

    CERN Document Server

    Izumi, Shuro; Wakui, Kentaro; Fujiwara, Mikio; Ema, Kazuhiro; Sasaki, Masahide

    2016-01-01

    We consider the phase sensing via weak optical coherent state at quantum limit precision. A new detection scheme for the phase estimation is proposed which is inspired by the suboptimal quantum measurement in coherent optical communication. We theoretically analyze a performance of our detection scheme, which we call the displaced-photon counting, for phase sensing in terms of the Fisher information and show that the displaced-photon counting outperforms the static homodyne and heterodyne detections in wide range of the target phase. The proof-of-principle experiment is performed with linear optics and a superconducting nanowire single photon detector. The result shows that our scheme overcomes the limit of the ideal homodyne measurement even under practical imperfections.

  4. Few-photon coherent nonlinear optics with a single molecule

    CERN Document Server

    Maser, Andreas; Utikal, Tobias; Götzinger, Stephan; Sandoghdar, Vahid

    2015-01-01

    The pioneering experiments of linear spectroscopy were performed using flames in the 1800s, but nonlinear optical measurements had to wait until lasers became available in the twentieth century. Because the nonlinear cross section of materials is very small, usually macroscopic bulk samples and pulsed lasers are used. Numerous efforts have explored coherent nonlinear signal generation from individual nanoparticles or small atomic ensembles with millions of atoms. Experiments on a single semiconductor quantum dot have also been reported, albeit with a very small yield. Here, we report on coherent nonlinear spectroscopy of a single molecule under continuous-wave single-pass illumination, where efficient photon-molecule coupling in a tight focus allows switching of a laser beam by less than a handful of pump photons nearly resonant with the sharp molecular transition. Aside from their fundamental importance, our results emphasize the potential of organic molecules for applications such as quantum information pro...

  5. Miniature optical coherence tomography system based on silicon photonics

    Science.gov (United States)

    Margallo-Balbás, Eduardo; Pandraud, Gregory; French, Patrick J.

    2008-02-01

    Optical Coherence Tomography (OCT) is a promising medical imaging technique. It has found applications in many fields of medicine and has a large potential for the optical biopsy of tumours. One of the technological challenges impairing faster adoption of OCT is the relative complexity of the optical instrumentation required, which translates into expensive and bulky setups. In this paper we report an implementation of Time Domain OCT (TD-OCT) based on a silicon photonic platform. The devices are fabricated using Silicon-On-Insulator (SOI) wafers, on which rib waveguides are defined. While most of the components needed are well-known in this technology, a fast delay line with sufficient scanning range is a specific requirement of TD-OCT. In the system reported, this was obtained making use of the thermo-optical effect of silicon. By modulating the thermal resistance of the waveguide to the substrate, it is possible to establish a trade-off between maximum working frequency and power dissipation. Within this trade-off, the systems obtained can be operated in the kHz range, and they achieve temperature shifts corresponding to scanning ranges of over 2mm. Though the current implementation still requires external sources and detectors to be coupled to the Planar Lightwave Circuit (PLC), future work will include three-dimensional integration of these components onto the substrate. With the potential to include the read-out and driving electronics on the same die, the reported approach can yield extremely compact and low-cost TD-OCT systems, enabling a wealth of new applications, including gastrointestinal pills with optical biopsy capabilities.

  6. Optical coherent and envelope detection for photonic wireless communication links

    DEFF Research Database (Denmark)

    Prince, Kamau; Zibar, Darko; Yu, Xianbin;

    We present two novel optical detection techniques for radio over fiber (RoF) communication links. Firstly, we present recent results obtained with optical digital coherent detection of optical phase-modulated ROF signals supporting error-free transmission over 25 km standard SMF with BPSK and QPSK...

  7. Photonic integrated circuits for the generation of coherent optical signals

    OpenAIRE

    Morrissey, Padraic E.

    2014-01-01

    The demand for optical bandwidth continues to increase year on year and is being driven primarily by entertainment services and video streaming to the home. Current photonic systems are coping with this demand by increasing data rates through faster modulation techniques, spectrally efficient transmission systems and by increasing the number of modulated optical channels per fibre strand. Such photonic systems are large and power hungry due to the high number of discrete components required i...

  8. Ultrafast coherent dynamics of a photonic crystal all-optical switch

    DEFF Research Database (Denmark)

    Colman, Pierre; Hansen, Per Lunnemann; Yu, Yi

    2016-01-01

    We present pump-probe measurements of an all-optical photonic crystal switch based on a nanocavity, resolving fast coherent temporal dynamics. The measurements demonstrate the importance of coherent effects typically neglected when considering nanocavity dynamics. In particular, we report...

  9. Coherent optical photons from shock waves in crystals.

    Science.gov (United States)

    Reed, Evan J; Soljacić, Marin; Gee, Richard; Joannopoulos, J D

    2006-01-13

    We predict that coherent electromagnetic radiation in the 1-100 THz frequency range can be generated in crystalline materials when subject to a shock wave or soliton-like propagating excitation. To our knowledge, this phenomenon represents a fundamentally new form of coherent optical radiation source that is distinct from lasers and free-electron lasers. The radiation is generated by the synchronized motion of large numbers of atoms when a shock wave propagates through a crystal. General analytical theory and NaCl molecular dynamics simulations demonstrate coherence lengths on the order of mm (around 20 THz) and potentially greater. The emission frequencies are determined by the shock speed and the lattice constants of the crystal and can potentially be used to determine atomic-scale properties of the shocked material.

  10. Ultrafast coherent dynamics of a photonic crystal all-optical switch

    CERN Document Server

    Colman, Pierre; Yu, Yi; Mørk, Jesper

    2016-01-01

    We present pump-probe measurements of an all-optical photonic crystal switch based on a nanocavity, resolving fast coherent temporal dynamics. The measurements demonstrate the importance of coherent effects typically neglected when considering nanocavity dynamics. In particular, we report the observation of an idler pulse. The measurements are in good agreement with a theoretical model that allows us to ascribe the observation to oscillations of the free carrier population in the nanocavity. The effect opens perspectives for the realization of new all-optical photonic crystal switches with unprecedented switching contrast.

  11. Self-trapping Characteristics of Partially Coherent Optical Beam in Photonic Crystal Fiber under Compton Scattering

    Institute of Scientific and Technical Information of China (English)

    HAO Dong-shan; LI Ji-zhou

    2007-01-01

    Using the mutually coherent function, the self-trapping of the circle partially coherent optical beam in the total internal reflective photonic crystal fiber(TIRPCF) under Compton scattering is studied.The study shows that the composition of the non-coherent optical beam in the optical spectrum and the diffraction effect are decreased by Compton scattering,and the probability of forming the soliton is greatly increased.The vibration peak value in the propagation,compressed degree,changed cycle,and radius of the soliton are all smaller than those before the scattering,but its coherent radius is larger than that before the scattering.In this propagation,the self-focusing plays a key role.

  12. Quantum optical coherence tomography using three time-energy entangled photons

    Science.gov (United States)

    Lopez-Mago, Dorilian; Burguete, Arturo; Campos, Eernesto

    2016-09-01

    Quantum Optical Coherence Tomography can achieve a greater image resolution compared to its classical counterpart, due to the entanglement of the photon pairs. Following the idea that higher the number of entangled photons, higher the resolution, we study the physical underpinnings that appear when using photon triplets. Unlike the usual Hong-Ou-Mandel interferometer used for QOCT, a much simpler implementation in the form of a Michelson interferometer is used in this work. We find that axial resolution can be improved by a factor of four. Additionally, we provide the numerical method to reconstruct the image given the triple coincidence rate.

  13. Generating single-photon catalyzed coherent states with quantum-optical catalysis

    Energy Technology Data Exchange (ETDEWEB)

    Xu, Xue-xiang, E-mail: xuxuexiang@jxnu.edu.cn [Center for Quantum Science and Technology, Jiangxi Normal University, Nanchang 330022 (China); Yuan, Hong-chun [College of Electrical and Optoelectronic Engineering, Changzhou Institute of Technology, Changzhou 213002 (China)

    2016-07-15

    We theoretically generate single-photon catalyzed coherent states (SPCCSs) by means of quantum-optical catalysis based on the beam splitter (BS) or the parametric amplifier (PA). These states are obtained in one of the BS (or PA) output channels if a coherent state and a single-photon Fock state are present in two input ports and a single photon is registered in the other output port. The success probabilities of the detection (also the normalization factors) are discussed, which is different for BS and PA catalysis. In addition, we prove that the generated states catalyzed by BS and PA devices are actually the same quantum states after analyzing photon number distribution of the SPCCSs. The quantum properties of the SPCCSs, such as sub-Poissonian distribution, anti-bunching effect, quadrature squeezing effect, and the negativity of the Wigner function are investigated in detail. The results show that the SPCCSs are non-Gaussian states with an abundance of nonclassicality. - Highlights: • We generate single-photon catalyzed coherent states with quantum-optical catalysis. • We prove the equivalent effects of the lossless beam splitter and the non-degenerate parametric amplifier. • Some nonclassical properties of the generated states are investigated in detail.

  14. A proposed fibre optic time domain optical coherence tomography system using a micro-photonic stationary optical delay line

    Science.gov (United States)

    Jansz, Paul Vernon; Wild, Graham; Hinckley, Steven

    2008-04-01

    Conventional time domain Optical Coherence Tomography (OCT) relies on a reference Optical Delay Line (ODL). These reference ODLs require the physical movement of a mirror to scan a given depth range. This movement results in instrument degradation. We propose a new optical fibre based time domain OCT system that makes use of a micro-photonic structure as a stationary ODL. The proposed system uses an in-fibre interferometer, either a Michelson or a Mach-Zhender. The reference ODL makes use of a collimator to expand the light from the optical fibre. This is them expanded in one dimension via planar optics, that is, a cylindrical lens based telescope, using a concave and convex lens. The expanded beam is them passed through a transmissive Spatial Light Modulator (SLM), specifically a liquid crystal light valve used as an optical switch. Light is then reflected back through the system off the micro-photonic structure. The micro-photonic structure is a one dimensional array of stagged mirror steps, called a Stepped Mirror Structure (SMS). The system enables the selection of discrete optical delay lengths. The proposed ODL is capable of depth hoping and multicasting. We discuss the fabrication of the SMS, which consists of eight steps, each approximately 150 μm high. A change in notch frequency using an in-fibre Mach Zhender interferometer was used to gauge the average step height. The results gave an average step height of 146 μm.

  15. Deterministic Photon Pairs and Coherent Optical Control of a Single Quantum Dot

    Science.gov (United States)

    Jayakumar, Harishankar; Predojević, Ana; Huber, Tobias; Kauten, Thomas; Solomon, Glenn S.; Weihs, Gregor

    2013-03-01

    The strong confinement of semiconductor excitons in a quantum dot gives rise to atomlike behavior. The full benefit of such a structure is best observed in resonant excitation where the excited state can be deterministically populated and coherently manipulated. Because of the large refractive index and device geometry it remains challenging to observe resonantly excited emission that is free from laser scattering in III/V self-assembled quantum dots. Here we exploit the biexciton binding energy to create an extremely clean single photon source via two-photon resonant excitation of an InAs/GaAs quantum dot. We observe complete suppression of the excitation laser and multiphoton emissions. Additionally, we perform full coherent control of the ground-biexciton state qubit and observe an extended coherence time using an all-optical echo technique. The deterministic coherent photon pair creation makes this system suitable for the generation of time-bin entanglement and experiments on the interaction of photons from dissimilar sources.

  16. Coherent optical propagation and ultrahigh resolution mass sensor based on photonic molecules optomechanics

    Science.gov (United States)

    Chen, Hua-Jun; Chen, Chang-Zhao; Li, Yang; Fang, Xian-Wen; Tang, Xu-Dong

    2017-01-01

    We theoretically demonstrate the coherent optical propagation properties based on a photonic molecules optomechanics. With choosing a suitable detuning of the pump field from optomechanical cavity resonance, both the slow- and fast-light effect of the probe field appear in the system. The coupling strength of the two cavities play a key role, which affords a quantum channel and influences the width of the transparency window. Based on the photonic molecules optomechanical system, a high resolution mass sensor is also proposed. The mass of external nanoparticles deposited onto the cavity can be measured straightforward via tracking the mechanical resonance frequency shifts due to mass changes in the probe transmission spectrum. Compared with the single-cavity optomechanics mass sensors, the mass resolution is improved significantly due to the cavity-cavity coupling. The photonic molecules optomechanics provide a new platform for on-chip applications in quantum information processing and ultrahigh resolution sensor devices.

  17. Optical Coherency Matrix Tomography

    Science.gov (United States)

    2015-10-19

    optics has been studied theoretically11, but has not been demonstrated experimentally heretofore. Even in the simplest case of two binary DoFs6 (e.g...coherency matrix G spanning these DoFs. This optical coherency matrix has not been measured in its entirety to date—even in the simplest case of two...dense coding, etc. CREOL, The College of Optics & Photonics, University of Central Florida, Orlando , Florida 32816, USA. Correspondence and requests

  18. Photonic Imaging with Optical Coherence Tomography for Quality Monitoring in the Poultry Industry: a Preliminary Study

    Directory of Open Access Journals (Sweden)

    M Sabuncu

    2015-09-01

    Full Text Available ABSTRACTA photonic imaging method that gives the possibility to measure egg quality was applied. Since the method is non-contact and non-destructive we believe that this photonic imaging method may be successfully integrated in the automated inspection systems in the poultry industry. The method involves scanning an invisible infrared light beam over the eggshell, allowing to detect possible cracks and reveal information about the structure of the eggshell. The high resolution, high quality measurements obtained through optical coherence tomography (OCT make it feasible to be utilized as part of an automated inspection system. In this paper we present an OCT scan image of the egg tip and reconstructed volumetric images of the eggshell surface. The method enables the detection of small cracks on eggs and reveals the detailed inner structures of the cracks.

  19. 0.54 {\\mu}m resolution two-photon interference with dispersion cancellation for quantum optical coherence tomography

    CERN Document Server

    Okano, Masayuki; Okamoto, Ryo; Nishizawa, Norihiko; Kurimura, Sunao; Takeuchi, Shigeki

    2016-01-01

    Quantum information technologies harness the intrinsic nature of quantum theory to beat the limitations of the classical methods for information processing and communication. Recently, the application of quantum features to metrology has attracted much attention. Quantum optical coherence tomography (QOCT), which utilizes two-photon interference between entangled photon pairs, is a promising approach to overcome the problem with optical coherence tomography (OCT): As the resolution of OCT becomes higher, degradation of the resolution due to dispersion within the medium becomes more critical. Here we report on the realization of 0.54 $\\mu$m resolution two-photon interference, which surpasses the current record resolution 0.75 $\\mu$m of low-coherence interference for OCT. In addition, the resolution for QOCT showed almost no change against the dispersion of a 1 mm thickness of water inserted in the optical path, whereas the resolution for OCT dramatically degrades. For this experiment, a highly-efficient chirpe...

  20. Coherent light transmission properties of commercial photonic crystal hollow core optical fiber.

    Science.gov (United States)

    Cranch, G A; Miller, G A

    2015-11-01

    Photonic crystal hollow core fiber (PC-HCF) has enabled many exciting new applications in nonlinear optics and spectroscopy. However, to date there has been less impact in coherent applications where preservation of optical phase over long fiber lengths is crucial. This paper presents characteristics of three commercially available PC-HCFs relevant to coherent applications including higher-order mode analysis, birefringence and polarization-dependent loss, and their impact on coherent light transmission in PC-HCF. Multipath interference due to higher-order mode propagation and Fresnel reflection is shown to generate excess intensity noise in transmission, which can be suppressed by up to 20 dB through high frequency phase modulation of the source laser. To demonstrate the potential of PC-HCF in high performance sensing, a Mach-Zehnder interferometer (MZI) incorporating 10 m of PC-HCF in each arm is characterized and demonstrates a phase resolution (59×10(-9)  rad/Hz(1/2) at 30 kHz) close to the shot noise limit, which is better than can be achieved in a MZI made with the same length of single mode solid core fiber because of the limit set by fundamental thermodynamic noise (74×10(-9)  rad/Hz(1/2) at 30 kHz).

  1. Backward Secondary-Wave Coherence Errors in Photonic Bandgap Fiber Optic Gyroscopes

    Science.gov (United States)

    Xu, Xiaobin; Song, Ningfang; Zhang, Zuchen; Jin, Jing

    2016-01-01

    Photonic bandgap fiber optic gyroscope (PBFOG) is a novel fiber optic gyroscope (FOG) with excellent environment adaptability performance compared to a conventional FOG. In this work we find and investigate the backward secondary-wave coherence (BSC) error, which is a bias error unique to the PBFOG and caused by the interference between back-reflection-induced and backscatter-induced secondary waves. Our theoretical and experimental results show a maximum BSC error of ~4.7°/h for a 300-m PBF coil with a diameter of 10 cm. The BSC error is an important error source contributing to bias instability in the PBFOG and has to be addressed before practical applications of the PBFOG can be implemented. PMID:27338388

  2. Sequential and coherent, optical and x-ray two-photon processes in atoms and molecules

    Science.gov (United States)

    Mills, Jeffrey Dean

    1997-09-01

    Vibronic and rovibronic implementations of conventional semiclassical theories, employing a phenomenological lineshape and descriptive of the absorption of a single photon by isolated chemical particles, are used to account for the absolute magnitude of the highly structured, broadband optical absorption, emission, radiation transfer, and refractive index of high- temperature (T ≈ 2000K), rare-gas-buffered, and locally equilibrated atomic and diatomic metal vapors (Li, Na, Al, and Li/Al). The polarized, resonant, inelastic scattering of x-rays (hν /approx 2.5 keV) from the K-edges of unoriented, chlorine- and sulfur- containing molecular gases (CH3Cl, H2S, and Cl2) is also modeled by means of the fully quantum- mechanical, time-independent Kramers-Heisenberg formalism applied in electronic and vibronic resolution. This accounts for the energy, polarization, and direction dependence of the anisotropic signal, concretely treats the demise of core-excited states by Auger-electron emission within the Feshbach-Fano theory of resonance- continuum mixing, and is in general valid for resonant, nonresonant, inelastic, and 'distinguishable' elastic scattering. Unusual, coherent interference phenomena within and between vibronic and electronic channels and related novel, otherwise-forbidden nondipole features expected to arise in molecules with equivalent atomic centers and recently observed in the chlorine molecule are explored along with their implications for common conceptions of 'localized, equivalent core-hole excited states.' Transition coherence, especially as manifested within the quantum-mechanical treatment of the spectral lineshape, is shown to provide the key to unifying the present single-step interpretation of two-photon x-ray scattering with that involving a pair of successive absorption and emission transitions generally regarded as two independent single-photon processes of the type described in the first portion of the work.

  3. Soliton fission and supercontinuum generation in photonic crystal fibre for optical coherence tomography application

    Indian Academy of Sciences (India)

    K Porsezian; R Vasantha Jayakantha Raja

    2015-11-01

    We present a practical design of novel photonic crystal fibre (PCF) to investigate the nonlinear propagation of femtosecond pulses for the application of optical coherence tomography (OCT) based on supercontinuum generation (SCG) process. In addition, this paper contains a brief introduction of the physical phenomena of soliton and SCG. Typically, here we discuss how the ultrabroadband radiation in PCF can be generated by SCG through various nonlinear effects of the fibre. To accomplish the proposed aim, we put forth liquid core PCF (LCPCF) structure filled with chloroform for OCT measurements of the eye. From the proposed design, we observe that proposed LCPCFs with liquid material exhibit significant broadened wavelength spectrum with low input pulse energy over small propagation distances for the OCT application.

  4. Coherent terahertz photonics.

    Science.gov (United States)

    Seeds, Alwyn J; Fice, Martyn J; Balakier, Katarzyna; Natrella, Michele; Mitrofanov, Oleg; Lamponi, Marco; Chtioui, Mourad; van Dijk, Frederic; Pepper, Michael; Aeppli, Gabriel; Davies, A Giles; Dean, Paul; Linfield, Edmund; Renaud, Cyril C

    2013-09-23

    We present a review of recent developments in THz coherent systems based on photonic local oscillators. We show that such techniques can enable the creation of highly coherent, thus highly sensitive, systems for frequencies ranging from 100 GHz to 5 THz, within an energy efficient integrated platform. We suggest that such systems could enable the THz spectrum to realize its full applications potential. To demonstrate how photonics-enabled THz systems can be realized, we review the performance of key components, show recent demonstrations of integrated platforms, and give examples of applications.

  5. Discrimination of optical coherent states using a photon number resolving detector

    DEFF Research Database (Denmark)

    Wittmann, C.; Andersen, Ulrik Lund; Leuchs, G.

    2010-01-01

    The discrimination of non-orthogonal quantum states with reduced or without errors is a fundamental task in quantum measurement theory. In this work, we investigate a quantum measurement strategy capable of discriminating two coherent states probabilistically with significantly smaller error...... probabilities than can be obtained using non-probabilistic state discrimination. We find that appropriate postselection of the measurement data of a photon number resolving detector can be used to discriminate two coherent states with small error probability. We compare our new receiver to an optimal...

  6. Progress in hollow core photonic crystal fiber for atomic vapour based coherent optics

    Science.gov (United States)

    Bradley, T. D.; Wang, Y. Y.; Alharbi, M.; Fourcade Dutin, C.; Mangan, B. J.; Wheeler, N. V.; Benabid, F.

    2012-03-01

    We report on progress in different hollow core photonic crystal fiber (HC-PCF) design and fabrication for atomic vapor based applications. We have fabricated a Photonic bandgap (PBG) guiding HC-PCF with a record loss of 107dB/km at 785nm in this class of fiber. A double photonic bandgap (DPBG) guiding HC-PCF with guidance bands centred at 780nm and 1064nm is reported. A 7-cell 3-ring Kagome HC-PCF with hypocycloid core is reported, the optical loss at 780nm has been reduced to 70dB/km which to the best of our knowledge is the lowest optical loss reported at this wavelength using HC-PCF. Details on experimental loading of alkali metal vapours using a far off red detuned laser are reported. This optical loading has been shown to decrease the necessary loading time for Rb into the hollow core of a fiber. The quantity of Rb within the fiber core has been enhanced by a maximum of 14% through this loading procedure.

  7. Large-core photonic microcells for coherent optics and laser metrology

    Science.gov (United States)

    Wheeler, N. V.; Grogan, M. D. W.; Wang, Y. Y.; Murphy, D. F.; Birks, T. A.; Benabid, F.

    2011-03-01

    A photonic microcell (PMC) is a length of gas-filled hollow core-photonic crystal fiber (HC-PCF) which is hermetically sealed at both ends by splicing to standard single mode fiber. We describe advances in the fabrication technique of PMCs which enable large core Kagome-lattice HC-PCFs to be integrated into PMC form. The modified fabrication technique uses fiber-tapering to accommodate the large dimensions of the fiber and enables low loss splices with single mode fiber by reducing mode field mismatch. Splice losses as low as 0.6 dB are achieved between 1-cell defect Kagome HC-PCF and single mode fiber. Relative to the previously reported PMCs, which were based on photonic bandgap HC-PCF, the present Kagome HC-PCF based PMC provides broad optical transmission, surface mode-free guidance and larger core at the cost of slightly increased fiber attenuation (~0.2 dB/m). Therefore, the integration of this fiber into PMC form opens up new applications for PMC-based devices. The advantage of the large core dimensions and surface mode free guidance for quantum optics in gas-filled HC-PCF are demonstrated by generation of narrow sub-Doppler features in an acetylenefilled large core PMC.

  8. Ultrahigh resolution optical coherence tomography with femtosecond Ti:sapphire laser and photonic crystal fiber

    Institute of Scientific and Technical Information of China (English)

    XUE Ping; James G FUJIMOTO

    2008-01-01

    Optical coherence tomography (OCT) with ultrahigh axial resolution was achieved by the super-contin- uum generated by coupling femtosecond pulses from a commercial Ti :sapphire laser into an air-silica microstructure fiber. The visible spectrum of the super-continuum from 450 to 700 nm centered at 540 nm can be generated. A free-space axial OCT resolution of 0.64 IJm was achieved. The sensitivity of OCT system was 108 dB with incident light power 3 mW at sample, only 7dB below the theoretical limit. Subcellular OCT imaging was also demonstrated, showing great potential for biomedical application.

  9. Quantum optical coherence can survive photon losses: a continuous-variable quantum erasure correcting code

    CERN Document Server

    Lassen, Mikael; Huck, Alexander; Niset, Julien; Leuchs, Gerd; Cerf, Nicolas J; Andersen, Ulrik L

    2010-01-01

    A fundamental requirement for enabling fault-tolerant quantum information processing is an efficient quantum error-correcting code (QECC) that robustly protects the involved fragile quantum states from their environment. Just as classical error-correcting codes are indispensible in today's information technologies, it is believed that QECC will play a similarly crucial role in tomorrow's quantum information systems. Here, we report on the first experimental demonstration of a quantum erasure-correcting code that overcomes the devastating effect of photon losses. Whereas {\\it errors} translate, in an information theoretic language, the noise affecting a transmission line, {\\it erasures} correspond to the in-line probabilistic loss of photons. Our quantum code protects a four-mode entangled mesoscopic state of light against erasures, and its associated encoding and decoding operations only require linear optics and Gaussian resources. Since in-line attenuation is generally the strongest limitation to quantum co...

  10. Plant photonics: application of optical coherence tomography to monitor defects and rots in onion

    Science.gov (United States)

    Meglinski, I. V.; Buranachai, C.; Terry, L. A.

    2010-04-01

    The incidence of physiological and/or pathological defects in many fresh produce types is still unacceptably high and accounts for a large proportion of waste. With increasing interest in food security their remains strong demand in developing reliable and cost effective technologies for non-destructive screening of internal defects and rots, these being deemed unacceptable by consumers. It is well recognized that the internal defects and structure of turbid scattering media can be effectively visualized by using optical coherence tomography (OCT). In the present study, the high spatial resolution and advantages of OCT have been demonstrated for imaging the skins and outer laminae (concentric tissue layers) of intact whole onion bulbs with a view to non-invasively visualizing potential incidence/severity of internal defects.

  11. Coherent amplified optical coherence tomography

    Science.gov (United States)

    Zhang, Jun; Rao, Bin; Chen, Zhongping

    2007-07-01

    A technique to improve the signal-to-noise ratio (SNR) of a high speed 1300 nm swept source optical coherence tomography (SSOCT) system was demonstrated. A semiconductor optical amplifier (SOA) was employed in the sample arm to coherently amplify the weak light back-scattered from sample tissue without increasing laser power illuminated on the sample. The image quality improvement was visualized and quantified by imaging the anterior segment of a rabbit eye at imaging speed of 20,000 A-lines per second. The theory analysis of SNR gain is given followed by the discussion on the technologies that can further improve the SNR gain.

  12. Photonic integrated Mach-Zehnder interferometer with an on-chip reference arm for optical coherence tomography.

    Science.gov (United States)

    Yurtsever, Günay; Považay, Boris; Alex, Aneesh; Zabihian, Behrooz; Drexler, Wolfgang; Baets, Roel

    2014-04-01

    Optical coherence tomography (OCT) is a noninvasive, three-dimensional imaging modality with several medical and industrial applications. Integrated photonics has the potential to enable mass production of OCT devices to significantly reduce size and cost, which can increase its use in established fields as well as enable new applications. Using silicon nitride (Si3N4) and silicon dioxide (SiO2) waveguides, we fabricated an integrated interferometer for spectrometer-based OCT. The integrated photonic circuit consists of four splitters and a 190 mm long reference arm with a foot-print of only 10 × 33 mm(2). It is used as the core of a spectral domain OCT system consisting of a superluminescent diode centered at 1320 nm with 100 nm bandwidth, a spectrometer with 1024 channels, and an x-y scanner. The sensitivity of the system was measured at 0.25 mm depth to be 65 dB with 0.1 mW on the sample. Using the system, we imaged human skin in vivo. With further optimization in design and fabrication technology, Si3N4/SiO2 waveguides have a potential to serve as a platform for passive photonic integrated circuits for OCT.

  13. Quantum optical coherence can survive photon losses using a continuous-variable quantum erasure-correcting code

    DEFF Research Database (Denmark)

    Lassen, Mikael Østergaard; Sabuncu, Metin; Huck, Alexander

    2010-01-01

    A fundamental requirement for enabling fault-tolerant quantum information processing is an efficient quantum error-correcting code that robustly protects the involved fragile quantum states from their environment. Just as classical error-correcting codes are indispensible in today's information t...... is generally the strongest limitation to quantum communication, such an erasure-correcting code provides a new tool for establishing quantum optical coherence over longer distances.......A fundamental requirement for enabling fault-tolerant quantum information processing is an efficient quantum error-correcting code that robustly protects the involved fragile quantum states from their environment. Just as classical error-correcting codes are indispensible in today's information...... technologies, it is believed that quantum error-correcting code will play a similarly crucial role in tomorrow's quantum information systems. Here, we report on the experimental demonstration of a quantum erasure-correcting code that overcomes the devastating effect of photon losses. Our quantum code is based...

  14. Low coherence technique to interrogate optical sensors based on selectively filled double-core photonic crystal fiber for temperature measurement

    Science.gov (United States)

    Li, Kun; Jiang, Meng; Zhao, Zhongze; Wang, Zeming

    2017-04-01

    In this paper, an optical fiber sensing system based on low coherence interferometry (LCI) is proposed and demonstrated to interrogate sensors comprised of selectively filled double-core photonic crystal fiber (SFDC-PCF). The sensor used here is made by selectively filling about 1/3 area of air holes in the cladding of photonic crystal fiber with distilled water. So the dual-core in the sensor has different effective refractive indices, resulting in a phase delay between two lights transmitting in the fiber. The phase delay of the sensor can be compensated by a Mach-Zehnder interferometer with a scanning optical tunable delay line in one arm of the interferometer, namely temporal interrogation. By tracking the value of phase delay, the change of the measurand can be detected. Temperature measurement is carried out to testify the system performance. An average sensitivity of 0.9 μm/°C is achieved within the temperature range of 29-92 °C. This work provides a new thinking for fiber sensing technology based on LCI. The proposed all-fiber sensing system, with the merits of cost-effective, stability, and flexibility, can demodulate the SFDC-PCF sensor signals well. Further improvements such as better sensitivity, larger measurement range and multiplexing efficiency can be realized by tailoring the PCF sensor's structure.

  15. A chip-integrated coherent photonic-phononic memory

    CERN Document Server

    Merklein, Moritz; Vu, Khu; Madden, Stephen J; Eggleton, Benjamin J

    2016-01-01

    Controlling and manipulating quanta of coherent acoustic vibrations - phonons - in integrated circuits has recently drawn a lot of attention, as phonons can function as unique links between radiofrequency and optical signals and access quantum regimes. It has been shown that radiofrequency signals can be controlled and stored via piezo-electrically actuated coherent phonons. Coherent phonons, however, can also be directly excited by optical photons through strong acousto-optic coupling in integrated circuits that guide photons as well as phonons. These hypersound phonons have similar wavelength as the exciting optical field but travel at a 5-orders of magnitude lower velocity. This allows the realization of a coherent optical buffer, a long time desired yet elusive device for on-chip optical signal processing. In this letter we demonstrate a coherent on-chip memory storing the entire coherent information carried by light, phase and amplitude, as acoustic phonons. The photonic-phononic memory provides GHz-band...

  16. Efficient quantum computing using coherent photon conversion.

    Science.gov (United States)

    Langford, N K; Ramelow, S; Prevedel, R; Munro, W J; Milburn, G J; Zeilinger, A

    2011-10-12

    Single photons are excellent quantum information carriers: they were used in the earliest demonstrations of entanglement and in the production of the highest-quality entanglement reported so far. However, current schemes for preparing, processing and measuring them are inefficient. For example, down-conversion provides heralded, but randomly timed, single photons, and linear optics gates are inherently probabilistic. Here we introduce a deterministic process--coherent photon conversion (CPC)--that provides a new way to generate and process complex, multiquanta states for photonic quantum information applications. The technique uses classically pumped nonlinearities to induce coherent oscillations between orthogonal states of multiple quantum excitations. One example of CPC, based on a pumped four-wave-mixing interaction, is shown to yield a single, versatile process that provides a full set of photonic quantum processing tools. This set satisfies the DiVincenzo criteria for a scalable quantum computing architecture, including deterministic multiqubit entanglement gates (based on a novel form of photon-photon interaction), high-quality heralded single- and multiphoton states free from higher-order imperfections, and robust, high-efficiency detection. It can also be used to produce heralded multiphoton entanglement, create optically switchable quantum circuits and implement an improved form of down-conversion with reduced higher-order effects. Such tools are valuable building blocks for many quantum-enabled technologies. Finally, using photonic crystal fibres we experimentally demonstrate quantum correlations arising from a four-colour nonlinear process suitable for CPC and use these measurements to study the feasibility of reaching the deterministic regime with current technology. Our scheme, which is based on interacting bosonic fields, is not restricted to optical systems but could also be implemented in optomechanical, electromechanical and superconducting

  17. Optical Coherence and Quantum Optics

    CERN Document Server

    Mandel, Leonard

    1995-01-01

    This book presents a systematic account of optical coherence theory within the framework of classical optics, as applied to such topics as radiation from sources of different states of coherence, foundations of radiometry, effects of source coherence on the spectra of radiated fields, coherence theory of laser modes, and scattering of partially coherent light by random media. The book starts with a full mathematical introduction to the subject area and each chapter concludes with a set of exercises. The authors are renowned scientists and have made substantial contributions to many of the topi

  18. Coherent Cherenkov radiation and laser oscillation in a photonic crystal

    CERN Document Server

    Denis, T; Lee, J H H; van der Meer, R; Strooisma, A; van der Slot, P J M; Vos, W L; Boller, K J

    2016-01-01

    We demonstrate that photonic crystals can be used to generate powerful and highly coherent laser radiation when injecting a beam of free electrons. Using theoretical investigations we present the startup dynamics and coherence properties of such laser, in which gain is provided by matching the optical phase velocity in the photonic crystal to the velocity of the electron beam.

  19. Optical Coherent Receiver Enables THz Wireless Bridge

    DEFF Research Database (Denmark)

    Yu, Xianbin; Liu, Kexin; Zhang, Hangkai

    2016-01-01

    We experimentally demonstrated a 45 Gbit/s 400 GHz photonic wireless communication system enabled by an optical coherent receiver, which has a high potential in fast recovery of high data rate connections, for example, in disaster....

  20. Maxwell equation simulations of coherent optical photon emission from shock waves in crystals.

    Science.gov (United States)

    Reed, Evan J; Soljacić, Marin; Joannopoulos, J D

    2007-05-01

    We have predicted that weak coherent radiation in the 1-100 THz frequency regime can be emitted under some circumstances when a shock wave propagates through a polarizable crystal, like NaCl [Reed, Phys. Rev. Lett. 96, 013904 (2006)]. In this work, we present and analyze a new model of a shocked polarizable crystal that is amenable to systematic analytical study and direct numerical solution of Maxwell's equations to predict emitted coherent field amplitudes and properties. Our simulations and analysis indicate that the field amplitude of the effect decreases rapidly with increasing shock front rise distance. These models establish a fundamental limit of the ratio of emitted terahertz amplitude to the static polarization of a material. While this effect is treated classically in our previous work, we present a quantum perturbation analysis showing that it can also occur in the low-amplitude emission quantum limit.

  1. Supercontinuum generation in optimized photonic crystal fiber at 1.3 μm for optical coherence tomography

    Directory of Open Access Journals (Sweden)

    Ferhat M. L.

    2016-01-01

    Full Text Available In this paper, we have designed a high nonlinear photonic crystal fiber (HN-PCF based on square-lattice geometry with the zero dispersion wavelength (ZDW around 1300 nm. The exploitation of different nonlinear mechanisms in the pulse propagation allows supercontinuum generation, which is used to enhance the axial resolution of the optical coherence tomography (OCT systems. First mechanism demonstrated is the soliton self-compression, we came up to realize pulse compression of 28.4 fs around 1300 nm by the generation of solitons of different orders to obtain ultrashort pulses of about 4 fs pulses in a PCF length of 66cm, then, we improved the pulse compression until 1.2 fs in a PCF length of 26 cm.The exploitation of the interplay between many nonlinear effects as self-phase modulation, intrapulse Raman scattering and self-steepening as second mechanism allows a generation of supercontinuum with a spectral bandwith of SBW=260 nm. The obtained spectral bandwidth could contribute to enhance the OCwith OCT imaging axial resolution which can be evaluated to 2.8 μm in air, working at 1.3 μm center wavelength which is widely used in several fields.

  2. Optical binding of cylinder photonic molecules in the near-field of partially coherent fluctuating Gaussian Schell model sources. A coherent mode representation

    CERN Document Server

    Auñón, Juan Miguel; Nieto-Vesperinas, Manuel

    2014-01-01

    We present a theory and computation method of radiation pressure from partially coherent light by establishing a coherent mode representation of the radiation forces. This is illustrated with the near field emitted from a Gaussian Schell model source, mechanically acting on a single cylinder with magnetodielectric behavior, or on a photonic molecule constituted by a pair of such cylinders. Thus after studying the force produced by a single particle, we address the effects of the spatial coherence on the bonding and anti-bonding states of two particles. The coherence length manifests the critical limitation of the contribution of evanescent modes to the scattered fields, and hence to the nature and strength of the electromagnetic fores, even when electric and/or magnetic partial wave resonances are excited.

  3. Photonic Astronomy and Quantum Optics

    CERN Document Server

    Dravins, Dainis

    2015-01-01

    Quantum optics potentially offers an information channel from the Universe beyond the established ones of imaging and spectroscopy. All existing cameras and all spectrometers measure aspects of the first-order spatial and/or temporal coherence of light. However, light has additional degrees of freedom, manifest in the statistics of photon arrival times, or in the amount of photon orbital angular momentum. Such quantum-optical measures may carry information on how the light was created at the source, and whether it reached the observer directly or via some intermediate process. Astronomical quantum optics may help to clarify emission processes in natural laser sources and in the environments of compact objects, while high-speed photon-counting with digital signal handling enables multi-element and long-baseline versions of the intensity interferometer. Time resolutions of nanoseconds are required, as are large photon fluxes, making photonic astronomy very timely in an era of large telescopes.

  4. Single photon emission based on coherent state preparation

    Science.gov (United States)

    Ester, P.; Lackmann, L.; Michaelis de Vasconcellos, S.; Hübner, M. C.; Zrenner, A.; Bichler, M.

    2007-09-01

    The authors report here on deterministic single photon emission after coherent optical state preparation in the p-shell of a single InGaAs /GaAs quantum dot. In the approach, they use p-shell Rabi flopping followed by relaxation to the s-shell ground state with subsequent spontaneous single photon emission. Pulsed photon correlation experiments show complete suppression of the correlation peak at zero time delay and hence demonstrate clean single photon emission.

  5. Silicon photonic integrated circuit swept-source optical coherence tomography receiver with dual polarization, dual balanced, in-phase and quadrature detection.

    Science.gov (United States)

    Wang, Zhao; Lee, Hsiang-Chieh; Vermeulen, Diedrik; Chen, Long; Nielsen, Torben; Park, Seo Yeon; Ghaemi, Allan; Swanson, Eric; Doerr, Chris; Fujimoto, James

    2015-07-01

    Optical coherence tomography (OCT) is a widely used three-dimensional (3D) optical imaging method with many biomedical and non-medical applications. Miniaturization, cost reduction, and increased functionality of OCT systems will be critical for future emerging clinical applications. We present a silicon photonic integrated circuit swept-source OCT (SS-OCT) coherent receiver with dual polarization, dual balanced, in-phase and quadrature (IQ) detection. We demonstrate multiple functional capabilities of IQ polarization resolved detection including: complex-conjugate suppressed full-range OCT, polarization diversity detection, and polarization-sensitive OCT. To our knowledge, this is the first demonstration of a silicon photonic integrated receiver for OCT. The integrated coherent receiver provides a miniaturized, low-cost solution for SS-OCT, and is also a key step towards a fully integrated high speed SS-OCT system with good performance and multi-functional capabilities. With further performance improvement and cost reduction, photonic integrated technology promises to greatly increase penetration of OCT systems in existing applications and enable new applications.

  6. Coherent optical pumping of semiconductor lasers

    Energy Technology Data Exchange (ETDEWEB)

    Pfister, M.; Dupertuis, M.A. [Inst. de Micro- et Optoelectronique, Lausanne (Switzerland). Dept. de Physique

    1995-01-01

    The influence of coherent optical pumping in semiconductor lasers is investigated theoretically. In particular the mathematical conditions under which an optically pumped system behaves like an electrically (incoherently) pumped system are derived. The authors show that it is practically impossible to reach the interesting regime where coherent effects are important because of the inherent constraints to absorb photons at the pump frequency and to reach threshold gain at the lasing frequency. The effects of changing the temperature and of reduced dimensionality are discussed.

  7. Dental Optical Coherence Tomography

    Directory of Open Access Journals (Sweden)

    Kun-Feng Lin

    2013-07-01

    Full Text Available This review paper describes the applications of dental optical coherence tomography (OCT in oral tissue images, caries, periodontal disease and oral cancer. The background of OCT, including basic theory, system setup, light sources, spatial resolution and system limitations, is provided. The comparisons between OCT and other clinical oral diagnostic methods are also discussed.

  8. Optical Coherence Tomography

    DEFF Research Database (Denmark)

    Andersen, Peter E.

    2015-01-01

    Optical coherence tomography (OCT) is a noninvasive imaging technique that provides real-time two- and three-dimensional images of scattering samples with micrometer resolution. Mapping the local reflectivity, OCT visualizes the morphology of the sample, in real time or at video rate. In addition...

  9. Optical Magnetometer Incorporating Photonic Crystals

    Science.gov (United States)

    Kulikov, Igor; Florescu, Lucia

    2007-01-01

    According to a proposal, photonic crystals would be used to greatly increase the sensitivities of optical magnetometers that are already regarded as ultrasensitive. The proposal applies, more specifically, to a state-of-the-art type of quantum coherent magnetometer that exploits the electromagnetically-induced-transparency (EIT) method for determining a small change in a magnetic field indirectly via measurement of the shift, induced by that change, in the hyperfine levels of resonant atoms exposed to the field.

  10. Optical coherence in astrophysics

    CERN Document Server

    Moret-Bailly, Jacques

    2013-01-01

    Many physicists and most astrophysicists assume that the photon is a small particle which, in a very low pressure gas can only interact with a single molecule. Thus, the interaction of light with this gas is incoherent. W. E.Lamb Jr, W. P. Schleich, M. O. Scully and C. H. Townes (Reviews of Modern Physics 71, S263, 1999) have criticized this view: In accordance with quantum electrodynamics the photon is a pseudo-particle resulting from the quantization of a deterministic exchange of energy between identical molecules and a normal mode of electromagnetic field. Following Lamb et al., we study models in which some variables have an unusual value for a spectroscopist: extremely low pressure hydrogen, but huge light paths, extremely hot sources. However, the magnitudes of the spectral radiances and column densities can be similar in astrophysics and in a laboratory using lasers. Thus, several coherent effects must be taken into account: superradiance, multiphoton interactions, impulsive stimulated Raman scatterin...

  11. Linear-optic heralded photon source

    Science.gov (United States)

    Ferreira da Silva, Thiago; Amaral, Gustavo C.; Temporão, Guilherme P.; von der Weid, Jean Pierre

    2015-09-01

    We present a heralded photon source based only on linear optics and weak coherent states. By time-tuning a Hong-Ou-Mandel interferometer fed with frequency-displaced coherent states, the output photons can be synchronously heralded following sub-Poisson statistics, which is indicated by the second-order correlation function [ g2(0 )=0.556 ]. The absence of phase-matching restrictions makes the source widely tunable, with 100-nm spectral tunability on the telecom bands. The technique presents yield comparable to state-of-the-art spontaneous parametric down-conversion-based sources, with high coherence and fiber-optic quantum communication compatibility.

  12. Nonlinear optics and photonics

    CERN Document Server

    He, Guang S

    2015-01-01

    This book provides a comprehensive presentation on most of the major topics in nonlinear optics and photonics, with equal emphasis on principles, experiments, techniques, and applications. It covers many major new topics including optical solitons, multi-photon effects, nonlinear photoelectric effects, fast and slow light , and Terahertz photonics. Chapters 1-10 present the fundamentals of modern nonlinear optics, and could be used as a textbook with problems provided at the end of each chapter. Chapters 11-17 cover the more advanced topics of techniques and applications of nonlinear optics and photonics, serving as a highly informative reference for researchers and experts working in related areas. There are also 16 pages of color photographs to illustrate the visual appearances of some typical nonlinear optical effects and phenomena. The book could be adopted as a textbook for both undergraduates and graduate students, and serve as a useful reference work for researchers and experts in the fields of physics...

  13. Photonics

    CERN Document Server

    Andrews, David L

    2015-01-01

    This book covers modern photonics accessibly and discusses the basic physical principles underlying all the applications and technology of photonicsThis volume covers the basic physical principles underlying the technology and all applications of photonics from statistical optics to quantum optics. The topics discussed in this volume are: Photons in perspective; Coherence and Statistical Optics; Complex Light and Singular Optics; Electrodynamics of Dielectric Media; Fast and slow Light; Holography; Multiphoton Processes; Optical Angular Momentum; Optical Forces, Trapping and Manipulation; Pol

  14. Optical Coherence Tomography

    Science.gov (United States)

    Huang, David

    Optical coherence tomography (OCT) is a new method for noninvasive cross-sectional imaging in biological systems. In OCT, the longitudinal locations of tissue structures are determined by measuring the time-of-flight delays of light backscattered from these structures. The optical delays are measured by low coherence interferometry. Information on lateral position is provided by transverse scanning of the probe beam. The two dimensional map of optical scattering from internal tissue microstructures is then represented in a false-color or grayscale image. OCT is the optical analog of ultrasonic pulse-echo imaging, but with greatly improved spatial resolutions (a few microns). This thesis describes the development of this new high resolution tomographic imaging technology and the demonstration of its use in a variety of tissues under both in vitro and in vivo conditions. In vitro OCT ranging and imaging studies were performed using human ocular and arterial tissues, two clinically relevant examples of transparent and turbid media, respectively. In the anterior eye, precise measurements of cornea and anterior chamber dimensions were made. In the arterial specimens, the differentiation between fatty -calcified and fibromuscular tissues was demonstrated. In vivo OCT imaging in the retina and optic nerve head in human subjects was also performed. The delineation of retinal layers, which has not been possible with other noninvasive imaging techniques, is demonstrated in these OCT images. OCT has high spatial resolution but limited penetration into turbid tissue. It has potential for diagnostic applications where high resolution is needed and optical access is available, such as in the eye, skin, surgically exposed tissues, and surfaces that can be reached by various catheters and endoscopic probes. In particular, the measurement of fine retinal structures promises improvements in the diagnosis and management of glaucoma, macular edema and other vitreo-retinal diseases

  15. Photonic crystal optical memory

    Science.gov (United States)

    Lima, A. Wirth; Sombra, A. S. B.

    2011-06-01

    After several decades pushing the technology and the development of the world, the electronics is giving space for technologies that use light. We propose and analyze an optical memory embedded in a nonlinear photonic crystal (PhC), whose system of writing and reading data is controlled by an external command signal. This optical memory is based on optical directional couplers connected to a shared optical ring. Such a device can work over the C-Band of ITU (International Telecommunication Union).

  16. Controlling light with high-Q silicon photonic crystal nanocavities: Photon confinement, nonlinearity and coherence

    Science.gov (United States)

    Yang, Xiaodong

    The strong light localization and long photon lifetimes in two-dimensional silicon photonic crystal nanocavities with high quality factor (Q ) and subwavelength modal volume (V) significantly enhance the light-matter interactions, presenting many opportunities to explore new functionalities in silicon nanophotonic integrated circuits for on-chip all-optical information processing, optical computation and optical communications. This thesis will focus on the design, nanofabrication, and experimental characterization of both passive and active silicon nanophotonic devices based on two-dimensional high-Q silicon photonic crystal nanocavities. Three topics of controlling light with these high-Q nanocavities will be presented, including (1) photon confinement mechanism and cavity resonance tuning, (2) enhancement of optical nonlinearities, and (3) all-optical analogue to coherent interferences. The first topic is photon confinement in two-dimensional high- Q silicon photonic crystal nanocavities. In Chapter 2, the role of Q/V as the figure of merit for the enhanced light-matter interaction in optical microcavities and nanocavities is explained and different types of high-Q optical microcavities and nanocavities are reviewed with an emphasis on two-dimensional photonic crystal nanocavities. Then the nanofabrication process and the Q characterization are illustrated for the two-dimensional silicon photonic crystal nanocavities. In Chapter 3, the post-fabrication digital resonance tuning of high-Q silicon photonic crystal nanocavities using atomic layer deposition is proposed and demonstrated, with wide tuning range and precise control of cavity resonances while preserving high quality factors. The second topic is the enhancement of optical nonlinearities in two-dimensional high-Q silicon photonic crystal nanocavities, including stimulated Raman scattering and thermo-optical nonlinearities. In Chapter 4, the enhanced stimulated Raman scattering for low threshold Raman

  17. Diffraction coherence in optics

    CERN Document Server

    Françon, M; Green, L L

    2013-01-01

    Diffraction: Coherence in Optics presents a detailed account of the course on Fraunhofer diffraction phenomena, studied at the Faculty of Science in Paris. The publication first elaborates on Huygens' principle and diffraction phenomena for a monochromatic point source and diffraction by an aperture of simple form. Discussions focus on diffraction at infinity and at a finite distance, simplified expressions for the field, calculation of the path difference, diffraction by a rectangular aperture, narrow slit, and circular aperture, and distribution of luminous flux in the airy spot. The book th

  18. Silicon photonics: optical modulators

    Science.gov (United States)

    Reed, G. T.; Gardes, F. Y.; Hu, Youfang; Thomson, D.; Lever, L.; Kelsall, R.; Ikonic, Z.

    2010-01-01

    Silicon Photonics has the potential to revolutionise a whole raft of application areas. Currently, the main focus is on various forms of optical interconnects as this is a near term bottleneck for the computing industry, and hence a number of companies have also released products onto the market place. The adoption of silicon photonics for mass production will significantly benefit a range of other application areas. One of the key components that will enable silicon photonics to flourish in all of the potential application areas is a high performance optical modulator. An overview is given of the major Si photonics modulator research that has been pursued at the University of Surrey to date as well as a worldwide state of the art showing the trend and technology available. We will show the trend taken toward integration of optical and electronic components with the difficulties that are inherent in such a technology.

  19. Coherent optical pulse sequencer for quantum applications.

    Science.gov (United States)

    Hosseini, Mahdi; Sparkes, Ben M; Hétet, Gabriel; Longdell, Jevon J; Lam, Ping Koy; Buchler, Ben C

    2009-09-10

    The bandwidth and versatility of optical devices have revolutionized information technology systems and communication networks. Precise and arbitrary control of an optical field that preserves optical coherence is an important requisite for many proposed photonic technologies. For quantum information applications, a device that allows storage and on-demand retrieval of arbitrary quantum states of light would form an ideal quantum optical memory. Recently, significant progress has been made in implementing atomic quantum memories using electromagnetically induced transparency, photon echo spectroscopy, off-resonance Raman spectroscopy and other atom-light interaction processes. Single-photon and bright-optical-field storage with quantum states have both been successfully demonstrated. Here we present a coherent optical memory based on photon echoes induced through controlled reversible inhomogeneous broadening. Our scheme allows storage of multiple pulses of light within a chosen frequency bandwidth, and stored pulses can be recalled in arbitrary order with any chosen delay between each recalled pulse. Furthermore, pulses can be time-compressed, time-stretched or split into multiple smaller pulses and recalled in several pieces at chosen times. Although our experimental results are so far limited to classical light pulses, our technique should enable the construction of an optical random-access memory for time-bin quantum information, and have potential applications in quantum information processing.

  20. Optical Coherence Tomography

    DEFF Research Database (Denmark)

    Mogensen, Mette; Themstrup, Lotte; Banzhaf, Christina

    2014-01-01

    as the optical analogue to ultrasound. The inherent safety of the technology allows for in vivo use of OCT in patients. The main strength of OCT is the depth resolution. In dermatology, most OCT research has turned on non-melanoma skin cancer (NMSC) and non-invasive monitoring of morphological changes......Optical coherence tomography (OCT) has developed rapidly since its first realisation in medicine and is currently an emerging technology in the diagnosis of skin disease. OCT is an interferometric technique that detects reflected and backscattered light from tissue and is often described...... in a number of skin diseases based on pattern recognition, and studies have found good agreement between OCT images and histopathological architecture. OCT has shown high accuracy in distinguishing lesions from normal skin, which is of great importance in identifying tumour borders or residual neoplastic...

  1. Photonic downconversion for coherent phase-modulated radio-over-fiber links using free-running local oscillator

    DEFF Research Database (Denmark)

    Caballero Jambrina, Antonio; Zibar, Darko; Schäffer, Christian G.

    2011-01-01

    A digital coherent receiver employing photonic downconversion is presented and experimentally demonstrated for phase-modulated radio-over-fiber optical links. Photonic downconversion adds additional advantages to optical phase modulated links by allowing demodulation of signals with RF carrier...

  2. Interaction of electron beams with optical nanostructures and metamaterials: from coherent photon sources towards shaping the wave function

    Science.gov (United States)

    Talebi, Nahid

    2017-10-01

    Investigating the interaction of electron beams with materials and light has been a field of research for more than a century. The field was advanced theoretically by the rise of quantum mechanics and technically by the introduction of electron microscopes and accelerators. It is possible nowadays to uncover a multitude of information from electron-induced excitations in matter by means of advanced techniques like holography, tomography, and, most recently, photon-induced near-field electron microscopy. The question is whether the interaction can be controlled in an even, more efficient way in order to unravel important questions like modal decomposition of the electron-induced polarization by performing experiments with better spatial, temporal, and energy resolutions. This review discusses recent advances in controlling electron and light interactions at the nanoscale. Theoretical and numerical aspects of the interaction of electrons with nanostructures and metamaterials will be discussed with the aim of understanding the mechanisms of radiation in the interaction of electrons with even more sophisticated structures. Based on these mechanisms of radiation, state-of-the art and novel electron-driven few-photon sources will be discussed. Applications of such sources to gain an understanding of quantum optical effects and also to perform spectral interferometry with electron microscopes will be covered. In an inverse approach, as in the case of the inverse Smith–Purcell effect, laser-induced excitations of nanostructures can cause electron beams traveling in the near-field of such structures to accelerate, provided a synchronization criterion is satisfied. This effect is the basis for linear dielectric and metallic electron accelerators. Moreover, acceleration is accompanied by bunching of the electrons. When single electrons are considered, an efficient design of nanostructures can lead to the shaping of the electron wave function travelling adjacent to them, for

  3. Observation of transverse coherent backscattering in disordered photonic structures

    CERN Document Server

    Brake, Sebastian; Leykam, Daniel; Desyatnikov, Anton; Denz, Cornelia

    2015-01-01

    We report on the experimental observation of weak localization in an optically induced disordered (2+1)-dimensional photonic structure. Our flexible method of optical induction is applied with a nondiffracting random intensity distribution. We focus on the analysis of a statistical output spectrum for many probe events with variance of the incoming beam's transverse spatial frequency. For particular spatial frequencies we find considerable signatures of transverse coherent backscattering.

  4. Coherent dynamics of a telecom-wavelength entangled photon source

    Science.gov (United States)

    Ward, M. B.; Dean, M. C.; Stevenson, R. M.; Bennett, A. J.; Ellis, D. J. P.; Cooper, K.; Farrer, I.; Nicoll, C. A.; Ritchie, D. A.; Shields, A. J.

    2014-02-01

    Quantum networks can interconnect remote quantum information processors, allowing interaction between different architectures and increasing net computational power. Fibre-optic telecommunications technology offers a practical platform for routing weakly interacting photonic qubits, allowing quantum correlations and entanglement to be established between distant nodes. Although entangled photons have been produced at telecommunications wavelengths using spontaneous parametric downconversion in nonlinear media, as system complexity increases their inherent excess photon generation will become limiting. Here we demonstrate entangled photon pair generation from a semiconductor quantum dot at a telecommunications wavelength. Emitted photons are intrinsically anti-bunched and violate Bell’s inequality by 17 standard deviations High-visibility oscillations of the biphoton polarization reveal the time evolution of the emitted state with exceptional clarity, exposing long coherence times. Furthermore, we introduce a method to evaluate the fidelity to a time-evolving Bell state, revealing entanglement between photons emitted up to 5 ns apart, exceeding the exciton lifetime.

  5. Ultrafast photonic crystal optical switching

    Institute of Scientific and Technical Information of China (English)

    GONG Qi-huang; HU Xiao-yong

    2006-01-01

    Photonic crystal,a novel and artificial photonic material with periodic dielectric distribution,possesses photonic bandgap and can control the propagation states of photons.Photonic crystal has been considered to be a promising candidate for the future integrated photonic devices.The properties and the fabrication method of photonic crystal are expounded.The progresses of the study of ultrafast photonic crystal optical switching are discussed in detail.

  6. Coherent optics in students' laboratories

    Science.gov (United States)

    Senderáková, Dagmar; Mesaros, Vladimir; Drzik, Milan

    2014-12-01

    Lasers provide us with unique kind of light - coherent light. Besides being the keystone of historical interferometric measuring methods, coherent waves, now accessible in a very easy way, become a base of new optical measuring and information processing methods. Moreover, holographic recording seems today to have become a common term, even among common, not especially optically educated people. The presentation deals with our attempt to take our students' interest in the coherence of light and getting them familiar with the phenomenon, indeed.

  7. Noncommutative $q$-photon added coherent states

    CERN Document Server

    Dey, Sanjib

    2016-01-01

    We construct the photon added coherent states of a noncommutative harmonic oscillator associated to a $q$-deformed oscillator algebra. Various nonclassical properties of the corresponding system are explored, first, by studying two different types of higher order quadrature squeezing, namely the Hillery-type and the Hong--Mandel-type and, second, by testing the sub-Poissonian nature of photon statistics in higher order with the help of the correlation function and the Mandel parameter. By comparing our results with those of the usual harmonic oscillator, we notice that the quadratures and photon number distributions in noncommutative case are more squeezed for the same values of the parameters and, thus, the photon added coherent states of noncommutative harmonic oscillator may be more nonclassical in comparison to the ordinary harmonic oscillator.

  8. Noncommutative q -photon-added coherent states

    Science.gov (United States)

    Dey, Sanjib; Hussin, Véronique

    2016-05-01

    We construct the photon-added coherent states of a noncommutative harmonic oscillator associated to a q -deformed oscillator algebra. Various nonclassical properties of the corresponding system are explored, first, by studying two different types of higher-order quadrature squeezing, namely, the Hillery type and the Hong-Mandel type, and second, by testing the sub-Poissonian nature of photon statistics in higher order with the help of the correlation function and the Mandel parameter. Also, we compare the behavior of different types of quadrature and photon number squeezing of our system with those of the ordinary harmonic oscillator by considering the same set of parameters.

  9. Advances in information optics and photonics

    CERN Document Server

    Friberg, Ari T

    2008-01-01

    This volume is the sixth in a series of books initiated in 1989 by the International Commission for Optics (ICO). These books highlight the advances and trends in the research and development of optical sciences, technologies, and applications at the time of their publication. In this age of the photon, information optics and photonics represent the key technologies to sustain our knowledge-based society. New concepts in classical and quantum-entangled light, coherent interaction with matter, and novel materials and processes have led to remarkable advances in today's information science and t

  10. Linear-Optic Heralded Photon Source

    OpenAIRE

    da Silva, Thiago Ferreira; Amaral, Gustavo C; Temporão, Guilherme P.; von der Weid, Jean Pierre

    2015-01-01

    We present a Heralded Photon Source based only on linear optics and weak coherent states. By time-tuning a Hong-Ou-Mandel interferometer fed with frequency-displaced coherent states, the output photons can be synchronously heralded following sub-Poisson statistics, which is indicated by the second-order correlation function ($g^2\\left(0\\right)=0.556$). The absence of phase-matching restrictions makes the source widely tunable, with 100-nm spectral tunability on the telecom bands. The techniqu...

  11. Optical Coherence Tomography

    Directory of Open Access Journals (Sweden)

    Pier Alberto Testoni

    2007-01-01

    Full Text Available Optical coherence tomography (OCT is an optical imaging modality that performs high-resolution, cross-sectional, subsurface tomographic imaging of the microstructure of tissues. The physical principle of OCT is similar to that of B-mode ultrasound imaging, except that it uses infrared light waves rather than acoustic waves. The in vivo resolution is 10–25 times better (about 10 µm than with high-frequency ultrasound imaging, but the depth of penetration is limited to 1–3 mm, depending on tissue structure, depth of focus of the probe used, and pressure applied to the tissue surface. In the last decade, OCT technology has evolved from an experimental laboratory tool to a new diagnostic imaging modality with a wide spectrum of clinical applications in medical practice, including the gastrointestinal tract and pancreatico-biliary ductal system. OCT imaging from the gastrointestinal tract can be done in humans by using narrow-diameter, catheter-based probes that can be inserted through the accessory channel of either a conventional front-view endoscope, for investigating the epithelial structure of the gastrointestinal tract, or a side-view endoscope, inside a standard transparent ERCP (endoscopic retrograde cholangiopancreatography catheter, for investigating the pancreatico-biliary ductal system. The esophagus and esophagogastric junction have been the most widely investigated organs so far; more recently, duodenum, colon, and the pancreatico-biliary ductal system have also been extensively investigated. OCT imaging of the gastrointestinal wall structure is characterized by a multiple-layer architecture that permits an accurate evaluation of the mucosa, lamina propria, muscularis mucosae, and part of the submucosa. The technique may therefore be used to identify preneoplastic conditions of the gastrointestinal tract, such as Barrett's epithelium and dysplasia, and evaluate the depth of penetration of early-stage neoplastic lesions. OCT imaging

  12. Coherent perfect absorption in photonic structures

    CERN Document Server

    Baldacci, Lorenzo; Tredicucci, Alessandro

    2016-01-01

    The ability to drive a system with an external input is a fundamental aspect of light-matter interaction. The coherent perfect absorption (CPA) phenomenon extends to the general multibeam interference phenomenology the well known critical coupling concepts. This interferometric control of absorption can be employed to reach full delivery of optical energy to nanoscale systems such as plasmonic nanoparticles, and multi-port interference can be used to enhance the absorption of a nanoscale device when it is embedded in a strongly scattering system, with potential applications to nanoscale sensing. Here we review the two-port CPA in reference to photonic structures which can resonantly couple to the external fields. A revised two-port theory of CPA is illustrated, which relies on the Scattering Matrix formalism and is valid for all linear two-port systems with reciprocity. Through a semiclassical approach, treating two-port critical coupling conditions in a non-perturbative regime, it is demonstrated that the st...

  13. Photonic Crystal Optical Tweezers

    CERN Document Server

    Wilson, Benjamin K; Bachar, Stephanie; Knouf, Emily; Bendoraite, Ausra; Tewari, Muneesh; Pun, Suzie H; Lin, Lih Y

    2009-01-01

    Non-invasive optical manipulation of particles has emerged as a powerful and versatile tool for biological study and nanotechnology. In particular, trapping and rotation of cells, cell nuclei and sub-micron particles enables unique functionality for various applications such as tissue engineering, cancer research and nanofabrication. We propose and demonstrate a purely optical approach to rotate and align particles using the interaction of polarized light with photonic crystal nanostructures to generate enhanced trapping force. With a weakly focused laser beam we observed efficient trapping and transportation of polystyrene beads with sizes ranging from 10 um down to 190 nm as well as cancer cell nuclei. In addition, we demonstrated alignment of non-spherical particles using a 1-D photonic crystal structure. Bacterial cells were trapped, rotated and aligned with optical intensity as low as 17 uW/um^2. Finite-difference time domain (FDTD) simulations of the optical near-field and far-field above the photonic c...

  14. Absence of Long-Range Coherence in the Parametric Emission from Photonic Wires

    OpenAIRE

    Wouters, M.; Carusotto, I.

    2005-01-01

    We analytically investigate the spatial coherence properties of the signal emission from one-dimensional optical parametric oscillators. Because of the reduced dimensionality, quantum fluctuations are able to destroy the long-range phase coherence even far above threshold. The spatial decay of coherence is exponential and, for realistic parameters of semiconductor photonic wires in the strong exciton-photon coupling regime, it is predicted to occur on an experimentally accessible length scale.

  15. Coherent resonant Ka-band photonic microwave receiver

    CERN Document Server

    Ilchenko, Vladimir S; Savchenkov, Anatoliy A; Seidel, David; Matsko, Andrey B; Maleki, Lute

    2008-01-01

    We propose theoretically and demonstrate experimentally a coherent microwave photonic receiver operating at 35 GHz carrier frequency. The device is based on a lithium niobate or lithium tantalate optical whispering gallery mode resonator coupled to a microwave strip line resonator. Microwave local oscillator is fed into the microwave resonator along with the microwave signal. We show that the sensitivity of this receiver significantly exceeds the sensitivity of the incoherent quadratic receiver based on the same technology. The coherent receiver can possess a dynamic range in excess of 100 dB in 5 MHz band if a low noise laser is utilized.

  16. Second harmonic optical coherence tomography

    OpenAIRE

    Jiang,Yi; Tomov, Ivan; Wang, Yimin; Chen, Zhongping

    2004-01-01

    Second harmonic optical coherence tomography, which uses coherence gating of second-order nonlinear optical response of biological tissues for imaging, is described and demonstrated. Femtosecond laser pulses were used to excite second harmonic waves from collagen harvested from rat tail tendon and a reference nonlinear crystal. Second harmonic interference fringe signals were detected and used for image construction. Because of the strong dependence of second harmonic generation on molecular ...

  17. Quantum nonlinear optics without photons

    Science.gov (United States)

    Stassi, Roberto; Macrı, Vincenzo; Kockum, Anton Frisk; Di Stefano, Omar; Miranowicz, Adam; Savasta, Salvatore; Nori, Franco

    2017-08-01

    Spontaneous parametric down-conversion is a well-known process in quantum nonlinear optics in which a photon incident on a nonlinear crystal spontaneously splits into two photons. Here we propose an analogous physical process where one excited atom directly transfers its excitation to a pair of spatially separated atoms with probability approaching 1. The interaction is mediated by the exchange of virtual rather than real photons. This nonlinear atomic process is coherent and reversible, so the pair of excited atoms can transfer the excitation back to the first one: the atomic analog of sum-frequency generation of light. The parameters used to investigate this process correspond to experimentally demonstrated values in ultrastrong circuit quantum electrodynamics. This approach can be extended to realize other nonlinear interatomic processes, such as four-atom mixing, and is an attractive architecture for the realization of quantum devices on a chip. We show that four-qubit mixing can efficiently implement quantum repetition codes and, thus, can be used for error-correction codes.

  18. Partial angular coherence and the angular Schmidt spectrum of entangled two-photon fields

    Energy Technology Data Exchange (ETDEWEB)

    Jha, Anand Kumar; Boyd, Robert W. [Institute of Optics, University of Rochester, Rochester, New York 14627 (United States); Agarwal, Girish S. [Department of Physics, Oklahoma State University, Stillwater, Oklahoma 74078 (United States)

    2011-12-15

    We study partially coherent fields that have a coherent-mode representation in the orbital-angular-momentum-mode basis. For such fields, we introduce the concepts of the angular coherence function and the coherence angle. Such fields are naturally produced by the process of parametric down-conversion--a second-order nonlinear optical process in which a pump photon breaks up into two entangled photons, known as the signal and idler photons. We show that the angular coherence functions of the signal and idler fields are directly related to the angular Schmidt (spiral) spectrum of the down-converted two-photon field and thus that the angular Schmidt spectrum can be measured directly by measuring the angular coherence function of either the signal or the idler field, without requiring coincidence detection.

  19. Two-point optical coherency matrix tomography.

    Science.gov (United States)

    Abouraddy, Ayman F; Kagalwala, Kumel H; Saleh, Bahaa E A

    2014-04-15

    The two-point coherence of an electromagnetic field is represented completely by a 4×4 coherency matrix G that encodes the joint polarization-spatial-field correlations. Here, we describe a systematic sequence of cascaded spatial and polarization projective measurements that are sufficient to tomographically reconstruct G--a task that, to the best of our knowledge, has not yet been realized. Our approach benefits from the correspondence between this reconstruction problem in classical optics and that of quantum state tomography for two-photon states in quantum optics. Identifying G uniquely determines all the measurable correlation characteristics of the field and, thus, lifts ambiguities that arise from reliance on traditional scalar descriptors, especially when the field's degrees of freedom are correlated or classically entangled.

  20. Semiconductor quantum optics with tailored photonic nanostructures

    Energy Technology Data Exchange (ETDEWEB)

    Laucht, Arne

    2011-06-15

    This thesis describes detailed investigations of the effects of photonic nanostructures on the light emission properties of self-assembled InGaAs quantum dots. Nanoscale optical cavities and waveguides are employed to enhance the interaction between light and matter, i.e. photons and excitons, up to the point where optical non-linearities appear at the quantum (single photon) level. Such non-linearities are an essential component for the realization of hardware for photon based quantum computing since they can be used for the creation and detection of non-classical states of light and may open the way to new genres of quantum optoelectronic devices such as optical modulators and optical transistors. For single semiconductor quantum dots in photonic crystal nanocavities we investigate the coupling between excitonic transitions and the highly localized mode of the optical cavity. We explore the non-resonant coupling mechanisms which allow excitons to couple to the cavity mode, even when they are not spectrally in resonance. This effect is not observed for atomic cavity quantum electrodynamics experiments and its origin is traced to phonon-assisted scattering for small detunings ({delta}E<{proportional_to}5 meV) and a multi-exciton-based, Auger-like process for larger detunings ({delta}E >{proportional_to}5 meV). For quantum dots in high-Q cavities we observe the coherent coupling between exciton and cavity mode in the strong coupling regime of light-matter interaction, probe the influence of pure dephasing on the coherent interaction at high excitation levels and high lattice temperatures, and examine the coupling of two spatially separated quantum dots via the exchange of real and virtual photons mediated by the cavity mode. Furthermore, we study the spontaneous emission properties of quantum dots in photonic crystal waveguide structures, estimate the fraction of all photons emitted into the propagating waveguide mode, and demonstrate the on-chip generation of

  1. Few-photon optical diode

    CERN Document Server

    Roy, Dibyendu

    2010-01-01

    We propose a novel scheme of realizing an optical diode at the few-photon level. The system consists of a one-dimensional waveguide coupled asymmetrically to a two-level system. The two or multi-photon transport in this system is strongly correlated. We derive exactly the single and two-photon current and show that the two-photon current is asymmetric for the asymmetric coupling. Thus the system serves as an optical diode which allows transmission of photons in one direction much more efficiently than the opposite.

  2. Few-photon optical diode

    OpenAIRE

    Roy, Dibyendu

    2010-01-01

    We propose a novel scheme of realizing an optical diode at the few-photon level. The system consists of a one-dimensional waveguide coupled asymmetrically to a two-level system. The two or multi-photon transport in this system is strongly correlated. We derive exactly the single and two-photon current and show that the two-photon current is asymmetric for the asymmetric coupling. Thus the system serves as an optical diode which allows transmission of photons in one direction much more efficie...

  3. Few-photon optical diode

    OpenAIRE

    Roy, Dibyendu

    2010-01-01

    We propose a novel scheme of realizing an optical diode at the few-photon level. The system consists of a one-dimensional waveguide coupled asymmetrically to a two-level system. The two or multi-photon transport in this system is strongly correlated. We derive exactly the single and two-photon current and show that the two-photon current is asymmetric for the asymmetric coupling. Thus the system serves as an optical diode which allows transmission of photons in one direction much more efficie...

  4. Experimental generation of optical coherence lattices

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Yahong; Cai, Yangjian, E-mail: serpo@dal.ca, E-mail: yangjiancai@suda.edu.cn [College of Physics, Optoelectronics and Energy and Collaborative Innovation Center of Suzhou Nano Science and Technology, Soochow University, Suzhou 215006 (China); Key Lab of Advanced Optical Manufacturing Technologies of Jiangsu Province and Key Lab of Modern Optical Technologies of Education Ministry of China, Soochow University, Suzhou 215006 (China); Ponomarenko, Sergey A., E-mail: serpo@dal.ca, E-mail: yangjiancai@suda.edu.cn [Department of Electrical and Computer Engineering, Dalhousie University, Halifax, Nova Scotia B3J 2X4 (Canada)

    2016-08-08

    We report experimental generation and measurement of recently introduced optical coherence lattices. The presented optical coherence lattice realization technique hinges on a superposition of mutually uncorrelated partially coherent Schell-model beams with tailored coherence properties. We show theoretically that information can be encoded into and, in principle, recovered from the lattice degree of coherence. Our results can find applications to image transmission and optical encryption.

  5. Optical coherence refractometry.

    Science.gov (United States)

    Tomlins, Peter H; Woolliams, Peter; Hart, Christian; Beaumont, Andrew; Tedaldi, Matthew

    2008-10-01

    We introduce a novel approach to refractometry using a low coherence interferometer at multiple angles of incidence. We show that for plane parallel samples it is possible to measure their phase refractive index rather than the group index that is usually measured by interferometric methods. This is a significant development because it enables bulk refractive index measurement of scattering and soft samples, not relying on surface measurements that can be prone to error. Our technique is also noncontact and compatible with in situ refractive index measurements. Here, we demonstrate this new technique on a pure silica test piece and a highly scattering resin slab, comparing the results with standard critical angle refractometry.

  6. Cubic meter volume optical coherence tomography

    Science.gov (United States)

    WANG, ZHAO; POTSAID, BENJAMIN; CHEN, LONG; DOERR, CHRIS; LEE, HSIANG-CHIEH; NIELSON, TORBEN; JAYARAMAN, VIJAYSEKHAR; CABLE, ALEX E.; SWANSON, ERIC; FUJIMOTO, JAMES G.

    2017-01-01

    Optical coherence tomography (OCT) is a powerful three-dimensional (3D) imaging modality with micrometer-scale axial resolution and up to multi-GigaVoxel/s imaging speed. However, the imaging range of high-speed OCT has been limited. Here, we report 3D OCT over cubic meter volumes using a long coherence length, 1310 nm vertical-cavity surface-emitting laser and silicon photonic integrated circuit dual-quadrature receiver technology combined with enhanced signal processing. We achieved 15 µm depth resolution for tomographic imaging at a 100 kHz axial scan rate over a 1.5 m range. We show 3D macroscopic imaging examples of a human mannequin, bicycle, machine shop gauge blocks, and a human skull/brain model. High-bandwidth, meter-range OCT demonstrates new capabilities that promise to enable a wide range of biomedical, scientific, industrial, and research applications. PMID:28239628

  7. All-optical information processing in photonic crystals

    Science.gov (United States)

    Yanik, Mehmet Fatih

    This thesis covers coherent and incoherent all-optical information processing using photonic bandgap nanostructures and microcavities. The first 3 chapters introduce all-optical bistable switching, transistor and memory elements with sub-micron scale dimensions. A strategy for large scale integration without optical isolators is also described. In chapters 4 and 5, dynamically modulated photonic crystal structures are introduced. It is shown that light pulses can be stopped and stored all-optically without requiring any coherent or resonant light-matter interaction. In chapter 6, it is shown that light pulses can be coherently time-reversed by using only index modulations and linear optics. In chapter 7, a supercomputer implementation of an object oriented finite difference time domain simulation is described to simulate photonic nanostructures with arbitrary material & geometric features.

  8. Integrated-optics-based optical coherence tomography

    NARCIS (Netherlands)

    Nguyen, D.V.

    2013-01-01

    Optical coherence tomography (OCT) is a high resolution, imaging technique that has developed over the last 20 years from a complicated laboratory setup into a ready-to-use commercially available device. Instead of using electronic time gating as being used by ultrasound (US) imaging, in OCT, the op

  9. Coherent signal processing in optical coherence tomography

    Science.gov (United States)

    Kulkarni, Manish Dinkarrao

    1999-09-01

    Optical coherence tomography (OCT) is a novel method for non-invasive sub-surface imaging of biological tissue micro-structures. OCT achieves high spatial resolution ( ~ 15 m m in three dimensions) using a fiber-optically integrated system which is suitable for application in minimally invasive diagnostics, including endoscopy. OCT uses an optical heterodyne detection technique based on white light interferometry. Therefore extremely faint reflections ( ~ 10 fW) are routinely detected with high spatial localization. The goal of this thesis is twofold. The first is to present a theoretical model for describing image formation in OCT, and attempt to enhance the current level of understanding of this new modality. The second objective is to present signal processing methods for improving OCT image quality. We present deconvolution algorithms to obtain improved longitudinal resolution in OCT. This technique may be implemented without increasing system complexity as compared to current clinical OCT systems. Since the spectrum of the light backscattered from bio-scatterers is closely associated with ultrastructural variations in tissue, we propose a new technique for measuring spectra as a function of depth. This advance may assist OCT in differentiating various tissue types and detecting abnormalities within a tissue. In addition to depth resolved spectroscopy, Doppler processing of OCT signals can also improve OCT image contrast. We present a new technique, termed color Doppler OCT (CDOCT). It is an innovative extension of OCT for performing spatially localized optical Doppler velocimetry. Micron-resolution imaging of blood flow in sub-surface vessels in living tissue using CDOCT is demonstrated. The fundamental issues regarding the trade- off between the velocity estimation precision and image acquisition rate are presented. We also present novel algorithms for high accuracy velocity estimation. In many blood vessels velocities tend to be on the order of a few cm

  10. Optical Coherence Tomography

    DEFF Research Database (Denmark)

    Fercher, A.F.; Andersen, Peter E.

    2017-01-01

    with a resolution comparable to conventional histology, but in real time, it can be used as a biopsy technique in a wide range of biological systems to detect diseases. These include the tomographic imaging of the internal microstructure of in vivo atherosclerotic plaques, the tomographic real-time diagnostics...... for intraoperative monitoring, and in microsurgical intervention. Optical biopsy based on OCT also provides diagnostic information by differentiating the architectural morphology of urological tissue, gastrointestinal tissue, and respiratory tissue....

  11. Coherent control of optical polarization effects in metamaterials

    Science.gov (United States)

    Mousavi, Seyedmohammad A.; Plum, Eric; Shi, Jinhui; Zheludev, Nikolay I.

    2015-01-01

    Processing of photonic information usually relies on electronics. Aiming to avoid the conversion between photonic and electronic signals, modulation of light with light based on optical nonlinearity has become a major research field and coherent optical effects on the nanoscale are emerging as new means of handling and distributing signals. Here we demonstrate that in slabs of linear material of sub-wavelength thickness optical manifestations of birefringence and optical activity (linear and circular birefringence and dichroism) can be controlled by a wave coherent with the wave probing the polarization effect. We demonstrate this in proof-of-principle experiments for chiral and anisotropic microwave metamaterials, where we show that the large parameter space of polarization characteristics may be accessed at will by coherent control. Such control can be exerted at arbitrarily low intensities, thus arguably allowing for fast handling of electromagnetic signals without facing thermal management and energy challenges. PMID:25755071

  12. Reversible quantum optical data storage based on resonant Raman optical field excited spin coherence.

    Science.gov (United States)

    Ham, Byoung S

    2008-09-01

    A method of reversible quantum optical data storage is presented using resonant Raman field excited spin coherence, where the spin coherence is stored in an inhomogeneously broadened spin ensemble. Unlike the photon echo method, in the present technique, a 2pi Raman optical rephasing pulse area is used and multimode (parallel) optical channels are available in which the multimode access gives a great benefit to quantum information processors such as quantum repeaters.

  13. Internal Defect Measurement of Scattering Media by Optical Coherence Microscopy

    Institute of Scientific and Technical Information of China (English)

    ZHU Yong-kai; ZHAO Hong; WANG Zhao; WANG Jun-li

    2005-01-01

    Optical coherence microscopy is applied to measure scattering media's internal defect, which based on low coherence interferometry and confocal microscopy. Optical coherence microscopy is more effective in the rejection of out of focus and multiple scattered photons originating further away of the focal plane. With the three-dimension scanning, the internal defect is detected by measuring the thickness of different points on the sample. The axial resolution is 6 μm and lateral resolution is 1.2 μm. This method is possessed of the advantages over the other measurement method of scattering media, such as non-destruction and highresolution.

  14. Coherent optical methods for metallography

    Energy Technology Data Exchange (ETDEWEB)

    Pechersky, M.J.

    1991-01-01

    Numerous methods based on coherent optical techniques have been developed over the past two decades for nondestructive evaluation, vibration analysis and experimental mechanics. These methods have a great deal of potential for the enhancement of metallographic evaluations and for materials characterization in general. One such technique described in this paper is the determination of the material damping factors in metals. Damping loss factors as low as 10-5 were measured on bronze and aluminum specimens using a technique based on laser vibrometry. Differences between cast and wrought bronze were easily distinguishable as well as the difference between the bronze and aluminum. Other coherent optical techniques may be used to evaluate residual stresses and to locate and identify microcracking, subsurface voids and other imperfections. These techniques and others can serve as a bridge between microstructural investigations and the macroscopic behavior of materials.

  15. Coherent optical methods for metallography

    Energy Technology Data Exchange (ETDEWEB)

    Pechersky, M.J.

    1991-12-31

    Numerous methods based on coherent optical techniques have been developed over the past two decades for nondestructive evaluation, vibration analysis and experimental mechanics. These methods have a great deal of potential for the enhancement of metallographic evaluations and for materials characterization in general. One such technique described in this paper is the determination of the material damping factors in metals. Damping loss factors as low as 10-5 were measured on bronze and aluminum specimens using a technique based on laser vibrometry. Differences between cast and wrought bronze were easily distinguishable as well as the difference between the bronze and aluminum. Other coherent optical techniques may be used to evaluate residual stresses and to locate and identify microcracking, subsurface voids and other imperfections. These techniques and others can serve as a bridge between microstructural investigations and the macroscopic behavior of materials.

  16. Wavefront sensing reveals optical coherence.

    Science.gov (United States)

    Stoklasa, B; Motka, L; Rehacek, J; Hradil, Z; Sánchez-Soto, L L

    2014-01-01

    Wavefront sensing is a set of techniques providing efficient means to ascertain the shape of an optical wavefront or its deviation from an ideal reference. Owing to its wide dynamical range and high optical efficiency, the Shack-Hartmann wavefront sensor is nowadays the most widely used of these sensors. Here we show that it actually performs a simultaneous measurement of position and angular spectrum of the incident radiation and, therefore, when combined with tomographic techniques previously developed for quantum information processing, the Shack-Hartmann wavefront sensor can be instrumental in reconstructing the complete coherence properties of the signal. We confirm these predictions with an experimental characterization of partially coherent vortex beams, a case that cannot be treated with the standard tools. This seems to indicate that classical methods employed hitherto do not fully exploit the potential of the registered data.

  17. Coherence Constraints and the Last Hidden Optical Coherence

    CERN Document Server

    Qian, Xiao-Feng; Vamivakas, A Nick; Eberly, Joseph H

    2016-01-01

    We have discovered a new domain of optical coherence, and show that it is the third and last member of a previously unreported fundamental triad of coherences. These are unified by our derivation of a parallel triad of coherence constraints that take the form of complementarity relations. We have been able to enter this new coherence domain experimentally and we describe the novel tomographic approach devised for that purpose.

  18. Hyperfine Coherence in the Presence of Spontaneous Photon Scattering

    CERN Document Server

    Ozeri, R; Jost, J D; De Marco, B L; Ben-Kish, A; Blakestad, B R; Britton, J L; Chiaverini, J; Itano, W M; Hume, D; Leibfried, D; Rosenband, T; Schmidt, P; Wineland, D J

    2005-01-01

    The coherence of a hyperfine-state superposition of a trapped $^{9}$Be$^+$ ion in the presence of off-resonant light is experimentally studied. It is shown that Rayleigh elastic scattering of photons that does not change state populations also does not affect coherence. Coherence times exceeding the average scattering time of 19 photons are observed. This result implies that, with sufficient control over its parameters, laser light can be used to manipulate hyperfine-state superpositions with very little decoherence.

  19. Coherent storage and phase modulation of single hard-x-ray photons using nuclear excitons.

    Science.gov (United States)

    Liao, Wen-Te; Pálffy, Adriana; Keitel, Christoph H

    2012-11-09

    The coherent storage and phase modulation of x-ray single-photon wave packets in the resonant scattering of light off nuclei is theoretically investigated. We show that by switching off and on again the magnetic field in the nuclear sample, phase-sensitive storage of photons in the keV regime can be achieved. Corresponding π phase modulation of the stored photon can be accomplished if the retrieving magnetic field is rotated by 180°. The development of such x-ray single-photon control techniques is a first step towards forwarding quantum optics and quantum information to shorter wavelengths and more compact photonic devices.

  20. Nonlinear optics with coherent free electron lasers

    Science.gov (United States)

    Bencivenga, F.; Capotondi, F.; Mincigrucci, R.; Cucini, R.; Manfredda, M.; Pedersoli, E.; Principi, E.; Simoncig, A.; Masciovecchio, C.

    2016-12-01

    We interpreted the recent construction of free electron laser (FELs) facilities worldwide as an unprecedented opportunity to bring concepts and methods from the scientific community working with optical lasers into the domain of x-ray science. This motivated our efforts towards the realization of FEL-based wave-mixing applications. In this article we present new extreme ultraviolet transient grating (X-TG) data from vitreous SiO2, collected using two crossed FEL pulses (photon frequency 38 eV) to generate the X-TG and a phase matched optical probing pulse (photon frequency 3.1 eV). This experiment extends our previous investigation, which was carried out on a nominally identical sample using a different FEL photon frequency (45 eV) to excite the X-TG. The present data are featured by a peak intensity of the X-TG signal substantially larger than that previously reported and by slower modulations of the X-TG signal at positive delays. These differences could be ascribed to the different FEL photon energy used in the two experiments or to differences in the sample properties. A systematic X-TG study on the same sample as a function of the FEL wavelength is needed to draw a consistent conclusion. We also discuss how the advances in the performance of the FELs, in terms of generation of fully coherent photon pulses and multi-color FEL emission, may push the development of original experimental strategies to study matter at the femtosecond-nanometer time-length scales, with the unique option of element and chemical state specificity. This would allow the development of advanced experimental tools based on wave-mixing processes, which may have a tremendous impact in the study of a large array of phenomena, ranging from nano-dynamics in complex materials to charge and energy transfer processes.

  1. Optical Photon Reassignment Microscopy (OPRA)

    CERN Document Server

    Roth, Stephan; Wicker, Kai; Heintzmann, Rainer

    2013-01-01

    To enhance the resolution of a confocal laser scanning microscope the additional information of a pinhole plane image taken at every excitation scan position can be used [C. J. R. Sheppard, Super-resolution in confocal imaging, Optik 80, 5354 (1988)]. This photon reassignment principle is based on the fact that the most probable position of an emitter is at half way between the nominal focus of the excitation laser and the position corresponding to the (off centre) detection position. Therefore, by reassigning the detected photons to this place, an image with enhanced detection efficiency and resolution is obtained. Here we present optical photon reassignment microscopy (OPRA) which realises this concept in an all-optical way obviating the need for image-processing. With the help of an additional intermediate optical beam expansion between descanning and a further rescanning of the detected light, an image with the advantages of photon reassignment can be acquired. Due to its simplicity and flexibility this m...

  2. Integrated Photonic Comb Generation: Applications in Coherent Communication and Sensing

    Science.gov (United States)

    Parker, John S.

    Integrated photonics combines many optical components including lasers, modulators, waveguides, and detectors in close proximity via homogeneous (monolithic) or heterogeneous (using multiple materials) integration. This improves stability for interferometers and lasers, reduces the occurrence of unwanted reflections, and it avoids coupling losses between different components as they are on the same chip. Thus, less power is needed to compensate for these added losses, and less heat needs to be removed due to these power savings. In addition, integration allows the many components that comprise a system to be fabricated together, thereby reducing the cost per system and allowing rapid scaling in production throughput. Integrated optical combs have many applications including: metrology, THz frequency generation, arbitrary waveform generation, optical clocks, photonic analog-to-digital converters, sensing (imaging), spectroscopy, and data communication. A comb is a set of optical sources evenly spaced in frequency. Several methods of comb generation including mode-locking and optical parametric oscillation produce phase-matched optical outputs with a fixed phase relationship between the frequency lines. When the absolute frequency of a single comb line is stabilized along with the frequency spacing between comb lines, absolute phase and frequency precision can be achieved over the entire comb bandwidth. This functionality provides tremendous benefits to many applications such as coherent communication and optical sensing. The goals for this work were achieving a broad comb bandwidth and noise reduction, i.e., frequency and phase stability. Integrated mode-locked lasers on the InGaAsP/InP material platform were chosen, as they could be monolithically integrated with the wide range of highly functional and versatile photonic integrated circuits (PICs) previously demonstrated on this platform at UCSB. Gain flattening filters were implemented to increase the comb

  3. Control of coherent information via on chip photonic-phononic emitter-receivers

    CERN Document Server

    Shin, Heedeuk; Jarecki, Robert; Starbuck, Andrew; Wang, Zheng; Rakich, Peter T

    2014-01-01

    Rapid progress in silicon photonics has fostered numerous chip-scale sensing, computing, and signal processing technologies. However, many crucial filtering and signal delay operations are difficult to perform with all-optical devices. Unlike photons propagating at luminal speeds, GHz-acoustic phonons with slow velocity allow information to be stored, filtered, and delayed over comparatively smaller length-scales with remarkable fidelity. Hence, controllable and efficient coupling between coherent photons and phonons enables new signal processing technologies that greatly enhance the performance and potential impact of silicon photonics. Here, we demonstrate a novel mechanism for coherent information processing based on traveling-wave photon-phonon transduction, which achieves a phonon emit-and-receive process between distinct nanophotonic waveguides. Using this device physics-which can support 1-20GHz frequencies-we create wavelength-insensitive radio-frequency photonic filters with an unrivaled combination ...

  4. Dynamic Optical Coherence Tomography Capillaroscopy

    DEFF Research Database (Denmark)

    Ring, Hans Christian; Themstrup, Lotte; Banzhaf, Christina Alette

    2016-01-01

    status, or morphology of the deeper dermal vessels. Dynamic optical coherence tomography (D-OCT) is a recently developed OCT technique that enables detection of high-speed changes in back-scattered light caused by moving cells in vessels. The high resolution of OCT enables the detection of the papillary...... loops. OBJECTIVE To explore the potential for OCT capillaroscopy of the nailfolds using D-OCT. DESIGN, SETTING, AND PARTICIPANTS In this case series study of 4 participants, the nailfolds in 2 patients with systemic sclerosis, 1 patient with dermatomyositis, and a healthy volunteer were scanned using D...

  5. Optical micromachines for photonic networks

    Science.gov (United States)

    Katagiri, Yoshitada

    2001-10-01

    The optical micromachines controlling the light in spatial and wavelength domains are based on the micro- optomechatronics which handles small objects in micrometers and covers the fields from monolithic fabrication and control techniques. Their advantageous features include quick response, high mechanical stability, and low driving power because of the small inertia effects. A wide variety of functions such as wavelength tuning and optical path switching has been realized. This paper describes typical applications corresponding to these functions and their possible implementations: optical manipulation for small optical components based on momentum transfer of photons, micro lenses fabricated monolithically on a substrate for optical integration circuits, tunable filters with moving mirrors driven by the electrostatic force fro pulse shaping, and optical switches based on thermo capillary for cross connect or add/drop multiplexing operations in network systems. These applications are useful for next-generation photonic reconfigurable networks.

  6. Optical Generation of Single- or Two-Mode Excited Entangled Coherent States

    Institute of Scientific and Technical Information of China (English)

    REN Zhen-Zhong; JING Hui; ZHANG Xian-Zhou

    2008-01-01

    With nonlinear Mach-Zehnder interferometer (NLMZI) and a type-Ⅰ beta-barium borate (BBO) crystal, we optically generate single-mode excited entangled coherent states. This scheme can be easily generalized to generate two-mode excited entangled coherent states. We simply analyse different influences of single- and two-mode photon excitations on entangled coherent states.

  7. Tomography of a Mode-Tunable Coherent Single-Photon Subtractor

    Science.gov (United States)

    Ra, Young-Sik; Jacquard, Clément; Dufour, Adrien; Fabre, Claude; Treps, Nicolas

    2017-07-01

    Single-photon subtraction plays important roles in optical quantum information processing as it provides a non-Gaussian characteristic in continuous-variable quantum information. While the conventional way of implementing single-photon subtraction based on a low-reflectance beam splitter works properly for a single-mode quantum state, it is unsuitable for a multimode quantum state because a single photon is subtracted from all multiple modes without maintaining their mode coherence. Here, we experimentally implement and characterize a mode-tunable coherent single-photon subtractor based on sum-frequency generation. It can subtract a single photon exclusively from one desired time-frequency mode of light or from a coherent superposition of multiple time-frequency modes. To experimentally characterize the time-frequency modes of the single-photon subtractor, we employ quantum process tomography based on coherent states. The mode-tunable coherent single-photon subtractor will be an essential element for realizing non-Gaussian quantum networks necessary to get a quantum advantage in information processing.

  8. Magnetic-field control of photon echo from the electron-trion system in a CdTe quantum well: shuffling coherence between optically accessible and inaccessible states.

    Science.gov (United States)

    Langer, L; Poltavtsev, S V; Yugova, I A; Yakovlev, D R; Karczewski, G; Wojtowicz, T; Kossut, J; Akimov, I A; Bayer, M

    2012-10-12

    We report on magnetic field-induced oscillations of the photon echo signal from negatively charged excitons in a CdTe/(Cd,Mg)Te semiconductor quantum well. The oscillatory signal is due to Larmor precession of the electron spin about a transverse magnetic field and depends sensitively on the polarization configuration of the exciting and refocusing pulses. The echo amplitude can be fully tuned from the maximum down to zero depending on the time delay between the two pulses and the magnetic-field strength. The results are explained in terms of the optical Bloch equations accounting for the spin level structure of electrons and trions.

  9. Optical Coherence Tomography: Advanced Modeling

    DEFF Research Database (Denmark)

    Andersen, Peter E.; Thrane, Lars; Yura, Harold T.;

    2013-01-01

    Analytical and numerical models for describing and understanding the light propagation in samples imaged by optical coherence tomography (OCT) systems are presented. An analytical model for calculating the OCT signal based on the extended Huygens-Fresnel principle valid both for the single......- and multiple-scattering regimes is derived. An advanced Monte Carlo model for calculating the OCT signal is also derived, and the validity of this model is shown through a mathematical proof based on the extended Huygens-Fresnel principle. From the analytical model, an algorithm for enhancing OCT images...... is developed, the so-called true-reflection algorithm in which the OCT signal may be corrected for the attenuation caused by scattering. The algorithm is verified experimentally and by using the Monte Carlo model as a numerical tissue phantom. Applications of extraction of optical properties from tissue...

  10. Coherent control of a strongly driven silicon vacancy optical transition in diamond

    CERN Document Server

    Zhou, Yu; Li, Ke; Xiong, Qihua; Aharonovich, Igor; Gao, Wei-bo

    2016-01-01

    The ability to prepare, optically read out and coherently control single quantum states is a key requirement for quantum information processing. Optically active solid state emitters have emerged as promising candidates with their prospects for on chip integration as quantum nodes and sources of coherent photons for connecting these nodes. Under strongly driving resonant laser field, such quantum emitter can exhibit quantum behavior such as Autler-Townes splitting and Mollow triplet spectrum. Here we demonstrate coherent control of a strongly driven optical transition in silicon vacancy (SiV) center in diamond. Rapid optical detection of photons enabled the observation of time resolved coherent Rabi oscillations and the Mollow triplet from an optical transition of a single SiV defect. Detection with a probing transition further confirmed Autler-Townes splitting generated by a strong laser field. Coherence time of the emitted photons is shown to be comparable to its lifetime and robust under very strong drivin...

  11. Optical coherent technologies in next generation access networks

    Science.gov (United States)

    Iwatsuki, Katsumi; Tsukamoto, Katsutoshi

    2012-01-01

    This paper reviews optical coherent technologies in next generation access networks with the use of radio over fiber (RoF), which offer key enabling technologies of wired and wireless integrated and/or converged broadband access networks to accommodate rapidly widespread cloud computing services. We describe technical issues on conventional RoF based on subcarrier modulation (SCM) and their countermeasures. Two examples of RoF access networks with optical coherent technologies to solve the technical issues are introduced; a video distribution system with FM conversion and wired and wireless integrated wide-area access network with photonic up- and down-conversion.

  12. Photonic Nanojet in Optical Tweezers

    CERN Document Server

    Neves, Antonio Alvaro Ranha

    2015-01-01

    Photonic nanojets has been brought into attention ten years ago for potential application as ultramicroscopy technique, using its sub-wavelength resolution to enhance detection and interaction with matter. For these novel applications under development, optically trapping a sphere, acts as an ideal framework to employ these nanojets. In this case, the nanojet is generated by a highly focused incident beam contrary to the traditional plane wave. It inherits the advantage from optical trapping, with the microsphere in equilibrium on the beam propagation axis, and be positioned arbitrarily in space, especially for intracellular applications. Moreover, due to optical scattering forces, when in equilibrium, there is a shift of the sphere centre with respect to the beam focus. However, within the stable equilibrium of an optical tweezers configuration, it does not allow the formation of a photonic nanojet. To overcome this, a double optical tweezers, in an unorthodox configuration of two collinearly and co-propagat...

  13. Increasing Entanglement between Gaussian States by Coherent Photon Subtraction

    DEFF Research Database (Denmark)

    Ourjoumtsev, Alexei; Dantan, Aurelien Romain; Tualle Brouri, Rosa

    2007-01-01

    We experimentally demonstrate that the entanglement between Gaussian entangled states can be increased by non-Gaussian operations. Coherent subtraction of single photons from Gaussian quadrature-entangled light pulses, created by a nondegenerate parametric amplifier, produces delocalized states w...

  14. Retinal Optical Coherence Tomography Imaging

    Science.gov (United States)

    Drexler, Wolfgang; Fujimoto, James G.

    The eye is essentially transparent, transmitting light with only minimal optical attenuation and scattering providing easy optical access to the anterior segment as well as the retina. For this reason, ophthalmic and especially retinal imaging has been not only the first but also most successful clinical application for optical coherence tomography (OCT). This chapter focuses on the development of OCT technology for retinal imaging. OCT has significantly improved the potential for early diagnosis, understanding of retinal disease pathogenesis, as well as monitoring disease progression and response to therapy. Development of ultrabroad bandwidth light sources and high-speed detection techniques has enabled significant improvements in ophthalmic OCT imaging performance, demonstrating the potential of three-dimensional, ultrahigh-resolution OCT (UHR OCT) to perform noninvasive optical biopsy of the living human retina, i.e., the in vivo visualization of microstructural, intraretinal morphology in situ approaching the resolution of conventional histopathology. Significant improvements in axial resolution and speed not only enable three-dimensional rendering of retinal volumes but also high-definition, two-dimensional tomograms, topographic thickness maps of all major intraretinal layers, as well as volumetric quantification of pathologic intraretinal changes. These advances in OCT technology have also been successfully applied in several animal models of retinal pathologies. The development of light sources emitting at alternative wavelengths, e.g., around #1,060 nm, not only enabled three-dimensional OCT imaging with enhanced choroidal visualization but also improved OCT performance in cataract patients due to reduced scattering losses in this wavelength region. Adaptive optics using deformable mirror technology, with unique high stroke to correct higher-order ocular aberrations, with specially designed optics to compensate chromatic aberration of the human eye, in

  15. Optical Microangiography Based on Optical Coherence Tomography

    Science.gov (United States)

    Reif, Roberto; Wang, Ruikang K.

    Proper homeostasis regulation of in vivo biological systems requires microvascular blood perfusion, which is the process of delivering blood into the tissue's capillary beds. Abnormal tissue vascularization has been associated with various diseases such as cancer, diabetes, neurological disorders, wounds, and inflammation. Understanding the changes in the vascular network or microangiography will have an important role in determining the causes and developing potential treatments for these diseases. Optical coherence tomography (OCT) is a noninvasive method for imaging three-dimensional biological tissues with high resolution (~10 µm) and without requiring the use of contrast agents. In this chapter we review several techniques for using OCT to determine blood flow velocities and the vessel morphology (optical microangiography). Different techniques will be discussed with a brief explanation of their limitations. Also, methods for quantifying these images are presented, as well as the depiction of several applications.

  16. Quantum theory of optical coherence selected papers and lectures

    CERN Document Server

    Glauber, Roy J

    2007-01-01

    A summary of the pioneering work of Glauber in the field of optical coherence phenomena and photon statistics, this book describes the fundamental ideas of modern quantum optics and photonics in a tutorial style. It is thus not only intended as a reference for researchers in the field, but also to give graduate students an insight into the basic theories of the field. Written by the Nobel Laureate himself, the concepts described in this book have formed the basis for three further Nobel Prizes in Physics within the last decade

  17. Coherent Cherenkov radiation and laser oscillation in a photonic crystal

    NARCIS (Netherlands)

    Denis, T.; van Dijk, M.W.; Lee, J.H.H.; van der Meer, R.; Strooisma, A.; van der Slot, Petrus J.M.; Vos, Willem L.; Boller, Klaus J.

    2016-01-01

    We demonstrate that photonic crystals can be used to generate powerful and highly coherent Cherenkov radiation that is excited by the injection of a beam of free electrons. Using theoretical and numerical investigations we present the startup dynamics and coherence properties of such a laser, in

  18. From optical MEMS to photonic crystal

    Science.gov (United States)

    Lee, Sukhan; Kim, Jideog; Lee, Hong-Seok; Moon, Il-Kwon; Won, JongHwa; Ku, Janam; Choi, Hyung; Shin, Hyungjae

    2002-10-01

    This paper presents the emergence of photonic crystals as significant optomechatronics components, following optical MEMS. It is predicted that, in the coming years, optical MEMS and photonic crystals may go through dynamic interactions leading to synergy as well as competition. First, we present the Structured Defect Photonic Crystal (SDPCTM) devised by the authors for providing the freedom of designing photonic bandgap structures, such that the application of photonic crystals be greatly extended. Then, we present the applications of optical MEMS and photonic crystals to displays and telecommunications. It is shown that many of the applications that optical MEMS can contribute to telecommunications and displays may be implemented by photonic crystals.

  19. Imaging granulomatous lesions with optical coherence tomography

    DEFF Research Database (Denmark)

    Banzhaf, Christina; Jemec, Gregor B E

    2012-01-01

    To investigate and compare the presentation of granulomatous lesions in optical coherence tomography (OCT) images and compare this to previous studies of nonmelanoma skin tumors.......To investigate and compare the presentation of granulomatous lesions in optical coherence tomography (OCT) images and compare this to previous studies of nonmelanoma skin tumors....

  20. Optical Properties of Photonic Crystals

    CERN Document Server

    Sakoda, Kazuaki

    2005-01-01

    This is the first comprehensive textbook on the optical properties of photonic crystals. It deals not only with the properties of the radiation modes inside the crystals but also with their peculiar optical response to external fields. A general theory of linear and nonlinear optical response is developed in a clear and detailed fashion using the Green's function method. The symmetry of the eigenmodes is treated systematically using group theory to show how it affects the optical properties of photonic crystals. Important recent developments such as the enhancement of stimulated emission, second harmonic generation, quadrature-phase squeezing, and low-threshold lasing are also treated in detail and made understandable. Numerical methods are also emphasized. Thus this book provides both an introduction for graduate and undergraduate students and also key information for researchers in this field. This second edition has been updated and includes a new chapter on superfluorescence.

  1. Coherent and incoherent spectral broadening in a photonic crystal fiber.

    Science.gov (United States)

    Gross, C; Best, Th; van Oosten, D; Bloch, I

    2007-07-01

    The coherence of the spectral broadening process is the key requisite for the application of supercontinua in frequency combs. We investigate the coherence of two subsequent supercontinuum pulses created in a photonic crystal fiber pumped by a femtosecond laser. We measure Young interference fringes from a Michelson-type interferometer at different wavelengths of the output spectrum and analyze their dependence on pump intensity and polarization. The visibility of these fringes is a direct measure of the coherence of the spectral broadening processes.

  2. Optical coherence tomography in dermatology

    Science.gov (United States)

    Sattler, Elke; Kästle, Raphaela; Welzel, Julia

    2013-06-01

    Optical coherence tomography (OCT) is a noninvasive diagnostic method that offers a view into the superficial layers of the skin in vivo in real-time. An infrared broadband light source allows the investigation of skin architecture and changes up to a depth of 1 to 2 mm with a resolution between 15 and 3 μm, depending on the system used. Thus OCT enables evaluation of skin lesions, especially nonmelanoma skin cancers and inflammatory diseases, quantification of skin changes, visualization of parasitic infestations, and examination of other indications such as the investigation of nails. OCT provides a quick and useful diagnostic imaging technique for a number of clinical questions and is a valuable addition or complement to other noninvasive imaging tools such as dermoscopy, high-frequency ultrasound, and confocal laser scan microscopy.

  3. Monte Carlo Simulations of Arterial Imaging with Optical Coherence Tomography

    Energy Technology Data Exchange (ETDEWEB)

    Amendt, P.; Estabrook, K.; Everett, M.; London, R.A.; Maitland, D.; Zimmerman, G.; Colston, B.; da Silva, L.; Sathyam, U.

    2000-02-01

    The laser-tissue interaction code LATIS [London et al., Appl. Optics 36, 9068 ( 1998)] is used to analyze photon scattering histories representative of optical coherence tomography (OCT) experiment performed at Lawrence Livermore National Laboratory. Monte Carlo photonics with Henyey-Greenstein anisotropic scattering is implemented and used to simulate signal discrimination of intravascular structure. An analytic model is developed and used to obtain a scaling law relation for optimization of the OCT signal and to validate Monte Carlo photonics. The appropriateness of the Henyey-Greenstein phase function is studied by direct comparison with more detailed Mie scattering theory using an ensemble of spherical dielectric scatterers. Modest differences are found between the two prescriptions for describing photon angular scattering in tissue. In particular, the Mie scattering phase functions provide less overall reflectance signal but more signal contrast compared to the Henyey-Greenstein formulation.

  4. Coherence length of photons from a single quantum system

    Science.gov (United States)

    Jelezko, F.; Volkmer, A.; Popa, I.; Rebane, K. K.; Wrachtrup, J.

    2003-04-01

    We present a methodology that allows recording the coherence length of photons emitted by a single quantum system in a solid. The feasibility of this approach is experimentally demonstrated by measuring the self-interference of photons from the zero-phonon line emission of a single nitrogen-vacancy defect in diamond at 1.6 K. The first-order correlation function has been recorded and analyzed in terms of a single exponential decay time. A coherence time of ˜5 ps has been obtained, which is in good agreement with the corresponding spectral line width and demonstrates the feasibility of the Fourier-transform spectroscopy with single photons.

  5. Optically Reconfigurable Photonic Devices

    CERN Document Server

    Wang, Qian; Gholipour, Behrad; Wang, Chih-Ming; Yuan, Guanghui; Teng, Jinghua; Zheludev, Nikolay I

    2015-01-01

    Optoelectronic components with adjustable parameters, from variable-focal-length lenses to spectral filters that can change functionality upon stimulation, have enormous technological importance. Tuning of such components is conventionally achieved by either micro- or nano-mechanical actuation of their consitutive parts, stretching or application of thermal stimuli. Here we report a new dielectric metasurface platform for reconfigurable optical components that are created with light in a non-volatile and reversible fashion. Such components are written, erased and re-written as two-dimensional binary or grey-scale patterns into a nanoscale film of phase change material by inducing a refractive-index-changing phase-transition with tailored trains of femtosecond pulses. We combine germanium-antimony-tellurium-based films optimized for high-optical-contrast ovonic switching with a sub-wavelength-resolution optical writing process to demonstrate technologically relevant devices: visible-range reconfigurable bi-chr...

  6. Optically switchable photonic metasurfaces

    Energy Technology Data Exchange (ETDEWEB)

    Waters, R. F.; MacDonald, K. F. [Centre for Photonic Metamaterials and Optoelectronics Research Centre, University of Southampton, Southampton SO17 1BJ (United Kingdom); Hobson, P. A. [QinetiQ Ltd., Cody Technology Park, Farnborough, Hampshire GU14 0LX (United Kingdom); Zheludev, N. I. [Centre for Photonic Metamaterials and Optoelectronics Research Centre, University of Southampton, Southampton SO17 1BJ (United Kingdom); Centre for Disruptive Photonic Technologies and The Photonics Institute, Nanyang Technological University, Singapore 637371 (Singapore)

    2015-08-24

    We experimentally demonstrate an optically switchable gallium-based metasurface, in which a reversible light-induced transition between solid and liquid phases occurring in a confined nanoscale surface layer of the metal drives significant changes in reflectivity and absorption. The metasurface architecture resonantly enhances the metal's “active plasmonic” phase-change nonlinearity by an order of magnitude, offering high contrast all-optical switching in the near-infrared range at low, μW μm{sup −2}, excitation intensities.

  7. Coherent control of optical activity and optical anisotropy of thin metamaterials

    CERN Document Server

    Mousavi, Seyedmohammad A; Shi, Jinhui; Zheludev, Nikolay I

    2013-01-01

    The future fibre optic communications network will rely on photons as carriers of information, which may be stored in intensity, polarization or phase of light. However, processing of such optical information usually relies on electronics. Aiming to avoid the conversion between optical and electronic signals, modulation of light with light based on optical nonlinearity has become a major research field, but real integrated all-optical systems face thermal management and energy challenges. On the other hand, it has recently been demonstrated that the interaction of two coherent light beams on a thin, lossy, linear material can lead to large and ultrafast intensity modulation at arbitrarily low power resulting from coherent absorption. Here we demonstrate that birefringence and optical activity (linear and circular birefringence and dichroism) of functional materials can be coherently controlled by placing a thin material slab into a standing wave formed by the signal and control waves. Efficient control of the...

  8. All-optical photon echo on a chip

    Science.gov (United States)

    Moiseev, E. S.; Moiseev, S. A.

    2017-01-01

    We demonstrate that a photon echo can be implemented by all-optical means using an array of on-chip high-finesse ring cavities whose parameters are chirped in such a way as to support equidistant spectra of cavity modes. When launched into such a system, a classical or quantum optical signal—even a single-photon field—becomes distributed between individual cavities, giving rise to prominent coherence echo revivals at well-defined delay times, controlled by the chirp of cavity parameters. This effect enables long storage times for high-throughput broadband optical delay and quantum memory.

  9. Coherent integrated receiver for highly linear microwave photonic links

    Science.gov (United States)

    Klamkin, Jonathan

    Phase modulation can be used to improve the signal-to-noise ratio and spurfree dynamic range (SFDR) of microwave photonic links because phase modulation is not limited in input modulation swing and is inherently linear using certain electro-optic devices. Traditional interferometer-based phase demodulators have a sinusoidal response therefore a novel approach is required for achieving linear coherent detection at the receive end of a photonic link employing phase modulation. In this work, a balanced receiver with feedback to a reference tracking phase modulator was developed. With sufficient feedback loop gain, the received signal phase is closely tracked and the phase detection falls within the linear regime of the interferometer response. For stable operation at high frequency the delay of the feedback loop must be kept short, therefore a monolithic approach is required to realize a compact receiver architecture. The monolithic photonic integrated circuit (PIC) developed here consists of a high power balanced uni-traveling-carrier photodiode (UTC-PD), a compact 2x2 multimode interference (MMI) coupler, and multi-quantum well reference phase modulators. This PIC is hybrid integrated with an electronic IC that provides transconductance amplification of the feedback signal for increased loop gain. Novel concepts such as charge compensation, partially depleted absorption, and absorption profile modification were incorporated into the design of the waveguide UTCPDs resulting in record output saturation current and linearity. Both general interference surface ridge (SR) MMI couplers and restricted interference deep ridge (DR) MMI couplers were explored, the latter for reducing the loop delay. Current injection tuning was incorporated into the MMI couplers for fine tuning the output power splitting ratio. The quantum well design of the reference phase modulators was optimized for realizing low Vpi, low insertion loss, low absorption modulation, and improved linearity

  10. Quantum Interference between a Single-Photon Fock State and a Coherent State

    CERN Document Server

    Windhager, Armin; Pacher, Christoph; Peev, Momtchil; Poppe, Andreas

    2010-01-01

    We derive analytical expressions for the single mode quantum field state at the individual output ports of a beam splitter when a single-photon Fock state and a coherent state are incident on the input ports. The output states turn out to be a statistical mixture between a displaced Fock state and a coherent state. Consequently we are able to find an analytical expression for the corresponding Wigner function. Because of the generality of our calculations the obtained results are valid for all passive and lossless optical four port devices. We show further how the results can be adapted to the case of the Mach-Zehnder interferometer. In addition we consider the case for which the single-photon Fock state is replaced with a general input state: a coherent input state displaces each general quantum state at the output port of a beam splitter with the displacement parameter being the amplitude of the coherent state.

  11. Quantum interference between a single-photon Fock state and a coherent state

    Science.gov (United States)

    Windhager, A.; Suda, M.; Pacher, C.; Peev, M.; Poppe, A.

    2011-04-01

    We derive analytical expressions for the single mode quantum field state at the individual output ports of a beam splitter when a single-photon Fock state and a coherent state are incident on the input ports. The output states turn out to be a statistical mixture between a displaced Fock state and a coherent state. Consequently we are able to find an analytical expression for the corresponding Wigner function. Because of the generality of our calculations the obtained results are valid for all passive and lossless optical four port devices. We show further how the results can be adapted to the case of the Mach-Zehnder interferometer. In addition we consider the case for which the single-photon Fock state is replaced with a general input state: a coherent input state displaces each general quantum state at the output port of a beam splitter with the displacement parameter being the amplitude of the coherent state.

  12. Coherent backscattering of inelastic photons from atoms and their mirror images

    CERN Document Server

    Moriya, P H; Teixeira, R Celistrino; Máximo, C E; Piovella, N; Bachelard, R; Kaiser, R; Courteille, Ph W

    2016-01-01

    Coherent backscattering is a coherence effect in the propagation of waves through disordered media involving two or more scattering events. Here, we report on the observation of coherent backscattering from individual atoms and their mirror images. This system displays two important advantages: First, the effect can be observed at low optical densities, which allows to work in very dilute clouds or far from resonance. Second, due to the fact that the radiation of an atom interferes constructively with that of its own image, the phenomenon is much more robust to dephasing induced by strong saturation. In particular, the contribution of inelastically scattered photons to the interference process is demonstrated.

  13. Optical Coherence Tomography in Tissue Engineering

    Science.gov (United States)

    Zhao, Youbo; Yang, Ying; Wang, Ruikang K.; Boppart, Stephen A.

    Tissue engineering holds the promise for a therapeutic solution in regenerative medicine. The primary goal of tissue engineering is the development of physiologically functional and biocompatible tissues/organs being implanted for the repair and replacement of damaged or diseased ones. Given the complexity in the developing processes of engineered tissues, which involves multi-dimensional interactions among cells of different types, three-dimensionally constructed scaffolds, and actively intervening bioreactors, a capable real-time imaging tool is critically required for expanding our knowledge about the developing process of desired tissues or organs. It has been recognized that optical coherence tomography (OCT), an emerging noninvasive imaging technique that provides high spatial resolution (up to the cellular level) and three-dimensional imaging capability, is a promising investigative tool for tissue engineering. This chapter discusses the existing and potential applications of OCT in tissue engineering. Example OCT investigations of the three major components of tissue engineering, i.e., cells, scaffolds, and bioreactors are overviewed. Imaging examples of OCT and its enabling functions and variants, e.g., Doppler OCT, polarization-sensitive OCT, optical coherence microscopy are emphasized. Remaining challenges in the application of OCT to tissue engineering are discussed, and the prospective solutions including the combination of OCT with other high-contrast and high-resolution modalities such as two-photon fluorescence microscopy are suggested as well. It is expected that OCT, along with its functional variants, will make important contributions toward revealing the complex cellular dynamics in engineered tissues as well as help us culture demanding tissue/organ implants that will advance regenerative medicine.

  14. Polarization-Sensitive Quantum Optical Coherence Tomography: Experiment

    CERN Document Server

    Booth, Mark C; Teich, Malvin Carl

    2010-01-01

    Polarization-sensitive quantum optical coherence tomography (PS-QOCT) makes use of a Type-II twin-photon light source for carrying out optical sectioning with polarization sensitivity. A BBO nonlinear optical crystal pumped by a Ti:sapphire psec-pulsed laser is used to confirm the theoretical underpinnings of this imaging paradigm. PS-QOCT offers even-order dispersion cancellation with simultaneous access to the group-velocity dispersion characteristics of the interstitial medium between the reflecting surfaces of the sample.

  15. Second-harmonic optical coherence tomography

    Science.gov (United States)

    Jiang, Yi; Tomov, Ivan; Wang, Yimin; Chen, Zhongping

    2004-05-01

    Second-harmonic optical coherence tomography, which uses coherence gating of second-order nonlinear optical responses of biological tissues for imaging, is described and demonstrated. Femtosecond laser pulses were used to excite second-harmonic waves from collagen harvested from rat tail tendon and a reference nonlinear crystal. Second-harmonic interference fringe signals were detected and used for image construction. Because of the strong dependence of second-harmonic generation on molecular and tissue structures, this technique imparts contrast and resolution enhancement to conventional optical coherence tomography.

  16. Coherence-Gated Sensorless Adaptive Optics Multiphoton Retinal Imaging

    Science.gov (United States)

    Cua, Michelle; Wahl, Daniel J.; Zhao, Yuan; Lee, Sujin; Bonora, Stefano; Zawadzki, Robert J.; Jian, Yifan; Sarunic, Marinko V.

    2016-09-01

    Multiphoton microscopy enables imaging deep into scattering tissues. The efficient generation of non-linear optical effects is related to both the pulse duration (typically on the order of femtoseconds) and the size of the focused spot. Aberrations introduced by refractive index inhomogeneity in the sample distort the wavefront and enlarge the focal spot, which reduces the multiphoton signal. Traditional approaches to adaptive optics wavefront correction are not effective in thick or multi-layered scattering media. In this report, we present sensorless adaptive optics (SAO) using low-coherence interferometric detection of the excitation light for depth-resolved aberration correction of two-photon excited fluorescence (TPEF) in biological tissue. We demonstrate coherence-gated SAO TPEF using a transmissive multi-actuator adaptive lens for in vivo imaging in a mouse retina. This configuration has significant potential for reducing the laser power required for adaptive optics multiphoton imaging, and for facilitating integration with existing systems.

  17. Coherence-Gated Sensorless Adaptive Optics Multiphoton Retinal Imaging.

    Science.gov (United States)

    Cua, Michelle; Wahl, Daniel J; Zhao, Yuan; Lee, Sujin; Bonora, Stefano; Zawadzki, Robert J; Jian, Yifan; Sarunic, Marinko V

    2016-09-07

    Multiphoton microscopy enables imaging deep into scattering tissues. The efficient generation of non-linear optical effects is related to both the pulse duration (typically on the order of femtoseconds) and the size of the focused spot. Aberrations introduced by refractive index inhomogeneity in the sample distort the wavefront and enlarge the focal spot, which reduces the multiphoton signal. Traditional approaches to adaptive optics wavefront correction are not effective in thick or multi-layered scattering media. In this report, we present sensorless adaptive optics (SAO) using low-coherence interferometric detection of the excitation light for depth-resolved aberration correction of two-photon excited fluorescence (TPEF) in biological tissue. We demonstrate coherence-gated SAO TPEF using a transmissive multi-actuator adaptive lens for in vivo imaging in a mouse retina. This configuration has significant potential for reducing the laser power required for adaptive optics multiphoton imaging, and for facilitating integration with existing systems.

  18. Dental optical coherence domain reflectometry explorer

    Energy Technology Data Exchange (ETDEWEB)

    Everett, Matthew J. (Livermore, CA); Colston, Jr., Billy W. (Livermore, CA); Sathyam, Ujwal S. (Livermore, CA); Da Silva, Luiz B. (Pleasanton, CA)

    2001-01-01

    A hand-held, fiber optic based dental device with optical coherence domain reflectometry (OCDR) sensing capabilities provides a profile of optical scattering as a function of depth in the tissue at the point where the tip of the dental explorer touches the tissue. This system provides information on the internal structure of the dental tissue, which is then used to detect caries and periodontal disease. A series of profiles of optical scattering or tissue microstructure are generated by moving the explorer across the tooth or other tissue. The profiles are combined to form a cross-sectional, or optical coherence tomography (OCT), image.

  19. Integrated structural and functional optical imaging combining spectral-domain optical coherence and multiphoton microscopy

    CERN Document Server

    Vinegoni, C; Luo, W; Marks, D L; Ralston, T; Tan, W

    2005-01-01

    An integrated microscope that combines different optical techniques for simultaneous imaging is demonstrated. The microscope enables spectral-domain optical coherence microscopy based on optical backscatter, and multi-photon microscopy for the detection of two-photon fluorescence and second harmonic generation signals. The unique configuration of this integrated microscope allows for the simultaneous acquisition of both anatomical (structural) and functional imaging information with particular emphasis for applications in the fields of tissue engineering and cell biology. In addition, the contemporary analysis of the spectroscopic features can enhance contrast by differentiating among different tissue components.

  20. All-optical coherent control of vacuum Rabi oscillations

    CERN Document Server

    Bose, Ranojoy; Choudhury, Kaushik Roy; Solomon, Glenn S; Waks, Edo

    2014-01-01

    When an atom strongly couples to a cavity, it can undergo coherent vacuum Rabi oscillations. Controlling these oscillatory dynamics quickly relative to the vacuum Rabi frequency enables remarkable capabilities such as Fock state generation and deterministic synthesis of quantum states of light, as demonstrated using microwave frequency devices. At optical frequencies, however, dynamical control of single-atom vacuum Rabi oscillations remains challenging. Here, we demonstrate coherent transfer of optical frequency excitation between a single quantum dot and a cavity by controlling vacuum Rabi oscillations. We utilize a photonic molecule to simultaneously attain strong coupling and a cavity-enhanced AC Stark shift. The Stark shift modulates the detuning between the two systems on picosecond timescales, faster than the vacuum Rabi frequency. We demonstrate the ability to add and remove excitation from the cavity, and perform coherent control of light-matter states. These results enable ultra-fast control of atom...

  1. Sub-THz photonic frequency conversion using optoelectronic transistors for future fully coherent access network systems

    Science.gov (United States)

    Otsuji, Taiichi; Sugawara, Kenta; Tamamushi, Gen; Dobroiu, Adrian; Suemitsu, Tetsuya; Ryzhii, Victor; Iwatsuki, Katsumi; Kuwano, Shigeru; Kani, Jun-ichi; Terada, Jun

    2016-02-01

    This paper reviews advances in sub-THz photonic frequency conversion using optoelectronic transistors for future fully coherent access network systems. Graphene-channel field effect transistors (G-FETs) and InP-based high electron mobility transistors (inP-HEMT) are experimentally examined as photonic frequency converters. Optoelectronic properties and three-terminal functionalities of the G-FETs and InP-HEMTs are exploited to perform single-chip photonic double-mixing operation over the 120 GHz wireless communication band. A single transistor can photomix the optical subcarriers to generate LO and mix down the RF data on the sub-THz carrier to the IF band.

  2. Photon propagation in a discrete fiber network: An interplay of coherence and losses

    CERN Document Server

    Regensburger, Alois; Hinrichs, Benjamin; Onishchukov, Georgy; Schreiber, Andreas; Silberhorn, Christine; Peschel, Ulf

    2011-01-01

    We study light propagation in a photonic system that shows stepwise evolution in a discretized environment. It resembles a discrete-time version of photonic waveguide arrays or quantum walks. By introducing controlled photon losses to our experimental setup, we observe unexpected effects like sub-exponential energy decay and formation of complex fractal patterns. This demonstrates that the interplay of linear losses, discreteness and energy gradients leads to genuinely new coherent phenomena in classical and quantum optical experiments. Moreover, the influence of decoherence is investigated.

  3. Photon propagation in a discrete fiber network: an interplay of coherence and losses.

    Science.gov (United States)

    Regensburger, Alois; Bersch, Christoph; Hinrichs, Benjamin; Onishchukov, Georgy; Schreiber, Andreas; Silberhorn, Christine; Peschel, Ulf

    2011-12-02

    We study light propagation in a photonic system that shows stepwise evolution in a discretized environment. It resembles a discrete-time version of photonic waveguide arrays or quantum walks. By introducing controlled photon losses to our experimental setup, we observe unexpected effects like subexponential energy decay and formation of complex fractal patterns. This demonstrates that the interplay of linear losses, discreteness and energy gradients leads to genuinely new coherent phenomena in classical and quantum optical experiments. Moreover, the influence of decoherence is investigated. © 2011 American Physical Society

  4. Adaptive optics optical coherence tomography in glaucoma.

    Science.gov (United States)

    Dong, Zachary M; Wollstein, Gadi; Wang, Bo; Schuman, Joel S

    2017-03-01

    Since the introduction of commercial optical coherence tomography (OCT) systems, the ophthalmic imaging modality has rapidly expanded and it has since changed the paradigm of visualization of the retina and revolutionized the management and diagnosis of neuro-retinal diseases, including glaucoma. OCT remains a dynamic and evolving imaging modality, growing from time-domain OCT to the improved spectral-domain OCT, adapting novel image analysis and processing methods, and onto the newer swept-source OCT and the implementation of adaptive optics (AO) into OCT. The incorporation of AO into ophthalmic imaging modalities has enhanced OCT by improving image resolution and quality, particularly in the posterior segment of the eye. Although OCT previously captured in-vivo cross-sectional images with unparalleled high resolution in the axial direction, monochromatic aberrations of the eye limit transverse or lateral resolution to about 15-20 μm and reduce overall image quality. In pairing AO technology with OCT, it is now possible to obtain diffraction-limited resolution images of the optic nerve head and retina in three-dimensions, increasing resolution down to a theoretical 3 μm(3). It is now possible to visualize discrete structures within the posterior eye, such as photoreceptors, retinal nerve fiber layer bundles, the lamina cribrosa, and other structures relevant to glaucoma. Despite its limitations and barriers to widespread commercialization, the expanding role of AO in OCT is propelling this technology into clinical trials and onto becoming an invaluable modality in the clinician's arsenal. Copyright © 2016 Elsevier Ltd. All rights reserved.

  5. Optical Coherence Tomography (OCT) in ophthalmology: introduction.

    Science.gov (United States)

    Fujimoto, James G; Drexler, Wolfgang; Schuman, Joel S; Hitzenberger, Christoph K

    2009-03-02

    The Optical Society (OSA) is pleased to present this special issue of Optics Express on "Optical Coherence Tomography (OCT) in Ophthalmology" as part of the new Interactive Science Publishing (ISP) project. The project is being performed in collaboration with the National Library of Medicine and represents a new paradigm for the publication of digital image and large dataset information.

  6. Coherence and incoherence in an optical comb.

    Science.gov (United States)

    Viktorov, Evgeny A; Habruseva, Tatiana; Hegarty, Stephen P; Huyet, Guillaume; Kelleher, Bryan

    2014-06-06

    We demonstrate a coexistence of coherent and incoherent modes in the optical comb generated by a passively mode-locked quantum dot laser. This is experimentally achieved by means of optical linewidth, radio frequency spectrum, and optical spectrum measurements and confirmed numerically by a delay-differential equation model showing excellent agreement with the experiment. We interpret the state as a chimera state.

  7. [Optical coherence tomography in solar eclipse retinopathy].

    Science.gov (United States)

    Calvo-González, C; Reche-Frutos, J; Santos-Bueso, E; Díaz-Valle, D; Benítez-del-Castillo, J M; García-Sánchez, J

    2006-05-01

    We describe the case of a patient suffering from acute visual loss soon after watching a solar eclipse. Optical coherence tomography was the main diagnostic tool used. Solar retinopathy is now an unusual cause of visual loss, although there are still some cases diagnosed, especially after viewing solar eclipses. Optical coherence tomography is suitable for detecting permanent retinal injuries related to solar exposure, with the outer retinal layers being typically affected.

  8. Rabi oscillations of two-photon states in nonlinear optical resonators

    Science.gov (United States)

    Sherkunov, Y.; Whittaker, David M.; Fal'ko, Vladimir

    2016-02-01

    We demonstrate that four-wave mixing processes in high-quality nonlinear resonators can lead to Rabi-like oscillations in photon occupation numbers and second-order correlation functions, being a characteristic feature of the presence of entangled photon pairs in the optical signal. In the case of a system driven by a continuous coherent pump, the oscillations occur in the transient regime. We show that driving the system with pulsed coherent pumping would generate strongly antibunched photon states.

  9. Coherent broadband light source for parallel optical coherence tomography

    NARCIS (Netherlands)

    Rivier, S.; Laversenne, L.; Bourquin, S.; Salathé, R.P.; Pollnau, M.; Grivas, C.; Shepherd, D.P.; Eason, R.W.; Flury, M.; Philipoussis, I.; Herzig, H.P.

    2004-01-01

    A Ti:sapphire planar waveguide is rib structured by Ar ion milling to provide parallel channel waveguides. By coupling high-power pump light through a microlens array into the waveguides, a novel broadband luminescent parallel emitter is demonstrated as a light source for parallel optical coherence

  10. Coherent Photon Mapping on the Intel MIC Architecture

    Institute of Scientific and Technical Information of China (English)

    Chun-Meng Kang; Lu Wang; Pei Wang; Yan-Ning Xu; Xiang-Xu Meng

    2015-01-01

    Photon mapping is a global illumination algorithm which is composed of two steps: photon tracing and photon searching. During photon searching step, each shading point needs to search the photon-tree to find k-neighbouring photons for reflected radiance estimation. As the number of shading points and the size of photon-tree are dramatically large, the photon searching step is time consuming. We propose a parallel photon searching algorithm by using radiance estimation approach for coherent shading points on the Intelr Many Integrated Core (MIC) Architecture. In order to efficiently use single instruction multiple data (SIMD) units, shading points are clustered by similarity first (every cluster contains 16 shading-points), and an initial neighbouring scope is searched from the photon-tree for each cluster. Then we use 16-wide SIMD units by performing k-NN searching from the initial neighbouring scope for those 16 shading-points in a cluster in parallel. We use the method to simulate some global illumination scenes on Intelr Xeonr processors and Intelr Xeonr PhiTM coprocessors. The comparison results with existing photon mapping techniques indicate that our method gives significant improvement in speed with the same accuracy.

  11. Theoretical study of Acousto-optical coherence tomography using random phase jumps on US and light

    CERN Document Server

    Gross, Michel; Ramaz, François; Farahi, Salma; Boccara, A C

    2011-01-01

    Acousto-optical coherence tomography (AOCT) is a variant of acousto-optic imaging (also called ultrasonic modulation imaging) that makes it possible to get the z resolution with acoustic and optic continuous wave beams. We describe here theoretically the AOCT effect, and we show that the acousto-optic "tagged photons" remain coherent if they are generated within a specific z region of the sample. We quantify the z selectivity for both the "tagged photon" field and for the Lesaffre et al. [Opt. Express 17, 18211 (2009)] photorefractive signal.

  12. Controlling light with light using coherent meta-devices: all-optical transistor, summator and invertor

    CERN Document Server

    Fang, Xu; Zheludev, Nikolay I

    2014-01-01

    Vast amounts of information are conveyed by photons in optical fibres, but most data processing is performed electronically, creating the infamous 'information bottleneck' and consuming energy at an increasingly unsustainable rate. The potential for photonic devices to manipulate light themselves remains unfulfilled, largely due to the absence of materials with strong, fast optical nonlinearities. Here we show that small-signal amplifier, summator and invertor functions for optical signals may all be realized with a 4-port device exploiting the coherent interaction of beams on a planar plasmonic metamaterial, assuming no intrinsic nonlinearity. We show that coherently controlled redistribution of energy among ports can deliver various forms of optical switching. Such devices can operate even at the single photon level, with THz bandwidth, and without introducing signal distortion, presenting powerful opportunities for novel optical data processing architectures, complexity oracles and the locally coherent net...

  13. Overlapped optics induced perfect coherent effects

    Science.gov (United States)

    Li, Jian Jie; Zang, Xiao Fei; Mao, Jun Fa; Tang, Min; Zhu, Yi Ming; Zhuang, Song Lin

    2013-12-01

    For traditional coherent effects, two separated identical point sources can be interfered with each other only when the optical path difference is integer number of wavelengths, leading to alternate dark and bright fringes for different optical path difference. For hundreds of years, such a perfect coherent condition seems insurmountable. However, in this paper, based on transformation optics, two separated in-phase identical point sources can induce perfect interference with each other without satisfying the traditional coherent condition. This shifting illusion media is realized by inductor-capacitor transmission line network. Theoretical analysis, numerical simulations and experimental results are performed to confirm such a kind of perfect coherent effect and it is found that the total radiation power of multiple elements system can be greatly enhanced. Our investigation may be applicable to National Ignition Facility (NIF), Inertial Confined Fusion (ICF) of China, LED lighting technology, terahertz communication, and so on.

  14. Observation of detection-dependent multi-photon coherence times

    DEFF Research Database (Denmark)

    Ra, Young-Sik; Tichy, Malte C.; Lim, Hyang-Tag;

    2013-01-01

    in which the multi-photon coherence time, defined by the width of the interference signal, depends on the number of interfering photons and on the measurement scheme chosen to detect the particles. A theoretical analysis reveals that all multi-photon interferences with more than two particles feature...... this dependence, which can be attributed to higher-order effects in the mutual indistinguishability of the particles. As a striking consequence, a single, well-defined many-particle quantum state can exhibit qualitatively different degrees of interference, depending on the chosen observable. Therefore, optimal...... sensitivity in many-particle quantum interferometry can only be achieved by choosing a suitable detection scheme....

  15. Observation of detection-dependent multi-photon coherence times

    DEFF Research Database (Denmark)

    Ra, Young-Sik; Tichy, Malte C.; Lim, Hyang-Tag

    2013-01-01

    The coherence time constitutes one of the most critical parameters that determines whether or not interference is observed in an experiment. For photons, it is traditionally determined by the effective spectral bandwidth of the photon. Here we report on multi-photon interference experiments...... this dependence, which can be attributed to higher-order effects in the mutual indistinguishability of the particles. As a striking consequence, a single, well-defined many-particle quantum state can exhibit qualitatively different degrees of interference, depending on the chosen observable. Therefore, optimal...

  16. Coherent analysis of quantum optical sideband modes

    CERN Document Server

    Huntington, E H; Robilliard, C; Ralph, T C

    2005-01-01

    We demonstrate a device that allows for the coherent analysis of a pair of optical frequency sidebands in an arbitrary basis. We show that our device is quantum noise limited and hence applications for this scheme may be found in discrete and continuous variable optical quantum information experiments.

  17. Coherence-Multiplexed Optical RF Feeder Networks

    NARCIS (Netherlands)

    Meijerink, Arjan; Taniman, Robert O.; Etten, van Wim

    2007-01-01

    An optical RF feeding system for wireless access is proposed, in which the radio access points are distinguished by means of coherence multiplexing (CM). CM is a rather unknown and potentially inexpensive optical code division multiple access technique, which is particularly suitable for relatively

  18. On-chip coherent conversion of photonic quantum signals between different degrees of freedom

    CERN Document Server

    Feng, Lan-Tian; Zhou, Zhi-Yuan; Li, Ming; Xiong, Xiao; Yu, Le; Shi, Bao-Sen; Guo, Guo-Ping; Dai, Dao-Xin; Ren, Xi-Feng; Guo, Guang-Can

    2016-01-01

    In quantum information process, a single quantum particle can have various degrees of freedom and with coherent coupling among them. To control multiple degrees of freedom simultaneously is necessary to describe the particle fully and, therefore, to use it more efficiently. As for photons, polarization, frequency, time, orbital angular momentum, and even transverse mode have been used in free-space and fiber quantum systems. Compared with free space and fiber optics, photonic integrated circuits (PICs) have attracted considerable attention owing to their small footprints, scalability, reduced power consumption, and enhanced processing stability, thus many quantum computation and quantum simulation protocols have been realized on quantum PICs (QPICs). It should be noted that, usually only one degree of freedom, for example, path or polarization, was used in those works. Here we demonstrate the coherent conversion of photonic quantum signals between different degrees of freedom on a single chip. By using mode m...

  19. Digital coherent receiver employing photonic downconversion for phase modulated radio-over-fibre links

    DEFF Research Database (Denmark)

    Zibar, Darko; Caballero Jambrina, Antonio; Guerrero Gonzalez, Neil

    2009-01-01

    A digital coherent receiver employing photonic downconversion is presented and experimentally demonstrated for phase-modulated radio-over-fibre optical links. The receiver is capable of operating at frequencies exceeding the bandwidth of electrical analog-to-digital converter by using photonic...... downconversion to translate the high-frequency input RF signal to the operating frequency range of the analog-to-digital converter. First, using linear digital demodulation scheme we measure SFDR of the link at microwave frequency of 5 GHz. Thereafter, successful signal demodulation of 50 Mbit/s binary phase...... shift keying (BPSK) modulated data signal at 5 GHz RF carrier frequency is experimentally demonstrated by using an analog-to-digital converter with only 1 GHz bandwidth. We successfully demonstrate signal demodulation, using the proposed digital coherent receiver with photonic downconversion, after 40...

  20. PREFACE: XVIII International Youth Scientific School "Coherent Optics and Optical Spectroscopy"

    Science.gov (United States)

    Salakhov, M. Kh; Samartsev, V. V.; Gainutdinov, R. Kh

    2015-05-01

    Kazan Federal University has held the annual International Youth School "Coherent Optics and Optical Spectroscopy" since 1997. The choice of the topic is not accidental. Kazan is the home of photon echo which was predicted at Kazan Physical-Technical Institute in 1963 by Prof. U.G. Kopvil'em and V.R. Nagibarov and observed in Columbia University by N.A. Kurnit, I.D. Abella, and S.R. Hartmann in 1964. Since then, photon echo has become a powerful tool of coherent optical spectroscopy and optical information processing, which have been developed here in Kazan in close collaboration between Kazan Physical-Technical Institute and Kazan Federal University. The main subjects of the XVIII International Youth School are: Nonlinear and coherent optics; Atomic and molecular spectroscopy; Coherent laser spectroscopy; Problems of quantum optics; Quantum theory of radiation; and Nanophotonics and Scanning Probe Microscopy. The unchallenged organizers of that school are Kazan Federal University and Kazan E.K. Zavoisky Physical-Technical Institute. The rector of the School is Professor Myakzyum Salakhov, and the vice-rector is Professor Vitaly Samartsev. The International Youth Scientific School "Coherent Optics and Optical Spectroscopy" follows the global pattern of comprehensive studies of matter properties and their interaction with electromagnetic fields. Since 1997 more than 100 famous scientists from the USA, Germany, Ukraine, Belarus and Russia have given plenary lecture presentations. Here over 1000 young scientists had an opportunity to participate in lively discussions about the latest scientific news. Many young people have submitted interesting reports on photonics, quantum electronics, laser physics, quantum optics, traditional optical and laser spectroscopy, non-linear optics, material science and nanotechnology. Here we are publishing the fullsize papers prepared from the most interesting lectures and reports selected by the Program Committee of the School. The

  1. Interfacing superconducting qubits and single optical photons

    CERN Document Server

    Das, Sumanta; Sørensen, Anders S

    2016-01-01

    We propose an efficient light-matter interface at optical frequencies between a superconducting qubit and a single photon. The desired interface is based on a hybrid architecture composed of an organic molecule embedded inside an optical waveguide and electrically coupled to a superconducting qubit far from the optical axis. We show that high fidelity, photon-mediated, entanglement between distant superconducting qubits can be achieved with incident pulses at the single photon level. Such low light level is highly sought for to overcome the decoherence of the superconducting qubit caused by absorption of optical photons.

  2. Nonlinear Photonics and Novel Optical Phenomena

    CERN Document Server

    Morandotti, Roberto

    2012-01-01

    Nonlinear Photonics and Novel Optical Phenomena contains contributed chapters from leading experts in nonlinear optics and photonics, and provides a comprehensive survey of fundamental concepts as well as hot topics in current research on nonlinear optical waves and related novel phenomena. The book covers self-accelerating airy beams, integrated photonics based on high index doped-silica glass, linear and nonlinear spatial beam dynamics in photonic lattices and waveguide arrays, polariton solitons and localized structures in semiconductor microcavities, terahertz waves, and other novel phenomena in different nanophotonic and optical systems.

  3. Photonic crystal negative refractive optics.

    Science.gov (United States)

    Baba, Toshihiko; Abe, Hiroshi; Asatsuma, Tomohiko; Matsumoto, Takashi

    2010-03-01

    Photonic crystals (PCs) are multi-dimensional periodic gratings, in which the light propagation is dominated by Bragg diffraction that appears to be refraction at the flat surfaces of the PC. The refraction angle from positive to negative, perfectly or only partially obeying Snell's law, can be tailored using photonic band theory. The negative refraction enables novel prism, collimation, and lens effects. Because PCs usually consist of two transparent media, these effects occur at absorption-free frequencies, affording significant design flexibility for free-space optics. The PC slab, a high-index membrane with a two-dimensional airhole array, must be carefully designed to avoid reflection and diffraction losses. Light focusing based on negative refraction forms a parallel image of a light source, facilitating optical couplers and condenser lenses for wavelength demultiplexing. A compact wavelength demultiplexer can be designed by combining the prism and lens effects. The collimation effect is obtainable not only inside but also outside of the PC by optimizing negative refractive condition.

  4. Optical biopsy of epithelial cancers by optical coherence tomography

    NARCIS (Netherlands)

    Wessels, R.; Wessels, R.; de Bruin, D.M.; Faber, D.J.; van Leeuwen, Ton; van Beurden, M.F.B.; Ruers, Theo J.M.

    2014-01-01

    Optical coherence tomography (OCT) is an optical technique that measures the backscattering of near-infrared light by tissue. OCT yields in 2D and 3D images at micrometer-scale resolution, thus providing optical biopsies, approaching the resolution of histopathological imaging. The technique has

  5. Optical coherent control in semiconductors

    DEFF Research Database (Denmark)

    Østergaard, John Erland; Vadim, Lyssenko; Hvam, Jørn Märcher

    2001-01-01

    of quantum control including the recent applications to semiconductors and nanostructures. We study the influence of inhomogeneous broadening in semiconductors on CC results. Photoluminescence (PL) and the coherent emission in four-wave mixing (FWM) is recorded after resonant excitation with phase...

  6. Photonics and Fiber Optics Processor Lab

    Data.gov (United States)

    Federal Laboratory Consortium — The Photonics and Fiber Optics Processor Lab develops, tests and evaluates high speed fiber optic network components as well as network protocols. In addition, this...

  7. Protecting an optical qubit against photon loss

    CERN Document Server

    Wasilewski, W; Wasilewski, Wojciech; Banaszek, Konrad

    2007-01-01

    We consider quantum error-correction codes for multimode bosonic systems, such as optical fields, that are affected by amplitude damping. Such a process is a generalization of an erasure channel. We demonstrate that the most accessible method of transforming optical systems with the help of passive linear networks has limited usefulness in preparing and manipulating such codes. These limitations stem directly from the recoverability condition for one-photon loss. We introduce a three-photon code protecting against the first order of amplitude damping, i.e. a single photon loss, and discuss its preparation using linear optics with single-photon sources and conditional detection. Quantum state and process tomography in the code subspace can be implemented using passive linear optics and photon counting. An experimental proof-of-principle demonstration of elements of the proposed quantum error correction scheme for a one-photon erasure lies well within present technological capabilites.

  8. Audio frequency in vivo optical coherence elastography

    Energy Technology Data Exchange (ETDEWEB)

    Adie, Steven G; Kennedy, Brendan F; Armstrong, Julian J; Alexandrov, Sergey A; Sampson, David D [Optical-Biomedical Engineering Laboratory (OBEL), School of Electrical, Electronic and Computer Engineering, University of Western Australia, 35 Stirling Highway, Crawley, Western Australia 6009 (Australia)], E-mail: dsampson@ee.uwa.edu.au

    2009-05-21

    We present a new approach to optical coherence elastography (OCE), which probes the local elastic properties of tissue by using optical coherence tomography to measure the effect of an applied stimulus in the audio frequency range. We describe the approach, based on analysis of the Bessel frequency spectrum of the interferometric signal detected from scatterers undergoing periodic motion in response to an applied stimulus. We present quantitative results of sub-micron excitation at 820 Hz in a layered phantom and the first such measurements in human skin in vivo.

  9. Optical coherence tomography in late solar retinopathy

    Directory of Open Access Journals (Sweden)

    Janković Aleksandar

    2011-01-01

    Full Text Available Introduction. Solar retinopathy refers to retinal injury induced by direct or indirect solar viewing. Case report. We presented a patient who had observed partial solar eclipse 51 year before. He had bilaterally decreased vision and scar of the macular region at the time of presentation. The basic diagnostic tool applied in the presented patient, optical coherence tomography, showed hyporeflexivity of the outer retina in the segment of retinal pigment epithelialphotoreceptors complex with atrophy and thinning of the foveolar region. Conclusion. Optical coherence tomography is a powerful, non-invasive diagnostic tool which can ease the diagnosis and estimate the level and nature of the macular region damage.

  10. Optics for coherent X-ray applications

    OpenAIRE

    2014-01-01

    Developments of X-ray optics for full utilization of diffraction-limited storage rings (DLSRs) are presented. The expected performance of DLSRs is introduced using the design parameters of SPring-8 II. To develop optical elements applicable to manipulation of coherent X-rays, advanced technologies on precise processing and metrology were invented. With propagation-based coherent X-rays at the 1 km beamline of SPring-8, a beryllium window fabricated with the physical-vapour-deposition method w...

  11. All-optical tunable photonic crystal cavity

    DEFF Research Database (Denmark)

    Pu, Minhao; Liu, Liu; Ou, Haiyan

    2010-01-01

    We demonstrate an ultra-small photonic crystal cavity with two resonant modes. An all-optical tuning operation based on the free-carrier plasma effect is, for the first time, realized utilizing a continuous wave light source. The termo-optical effect is minimized by isoproponal infiltration...... of the photonic crystal structure....

  12. All-optical tunable photonic crystal cavity

    DEFF Research Database (Denmark)

    Pu, Minhao; Liu, Liu; Ou, Haiyan;

    2010-01-01

    We demonstrate an ultra-small photonic crystal cavity with two resonant modes. An all-optical tuning operation based on the free-carrier plasma effect is, for the first time, realized utilizing a continuous wave light source. The termo-optical effect is minimized by isoproponal infiltration...... of the photonic crystal structure....

  13. Demonstrational Optics Part 2: Coherent and Statistical Optics

    CERN Document Server

    Marchenko, Oleg; Windholz, Laurentius

    2007-01-01

    Demonstrational Optics presents a new didactical approach to the study of optics. Emphasizing the importance of elaborate new experimental demonstrations, pictorial illustrations, computer simulations and models of optical phenomena in order to ensure a deeper understanding of wave and geometric optics. It includes problems focused on the pragmatic needs of students, secondary school teachers, university professors and optical engineers. Part 2, Coherent and Statistical Optics, contains chapters on interference, diffraction, Fourier optics, light quanta, thermal radiation (Shot noise and Gaussian light), Correlation of light fields and Correlation of light intensities. A substantial part of this volume is devoted to thermal radiation and its properties, especially with partial coherence. A detailed treatment of the photo-effect with respect to statistical properties leads to the basics of statistical optics. To illustrate the phenomena covered by this volume, a large number of demonstration experiments are de...

  14. Temporal coherence and correlation of counterpropagating twin photons

    CERN Document Server

    Gatti, Alessandra; Brambilla, Enrico

    2015-01-01

    This work analyses the temporal coherence and correlation of counterpropagating twin photons generated in a quasi-phase matched nonlinear cristal by spontaneous parametric-down conversion. We find out different pictures depending on the pump pulse duration relative to two characteristic temporal scales, determined respectively by the temporal separation between the counter-propagating and the co-propagating wavepackets. When the pump duration is intermediate between the two scales, we show a transition from a highly entangled state to an almost separable state, with strongly asymmetric spectral properties of the photons.

  15. Entangled-photon Fourier optics

    CERN Document Server

    Abouraddy, A F; Sergienko, A V; Teich, M C; Abouraddy, Ayman F.; Saleh, Bahaa E. A.; Sergienko, Alexander V.; Teich, Malvin C.

    2002-01-01

    Entangled photons, generated by spontaneous parametric down-conversion from a second-order nonlinear crystal, present a rich potential for imaging and image-processing applications. Since this source is an example of a three-wave mixing process, there is more flexibility in the choices of illumination and detection wavelengths and in the placement of object(s) to be imaged. Moreover, this source is entangled, a fact that allows for imaging configurations and capabilities that cannot be achieved using classical sources of light. In this paper we examine a number of imaging and image-processing configurations that can be realized using this source. The formalism that we utilize facilitates the determination of the dependence of imaging resolution on the physical parameters of the optical arrangement.

  16. Topological photonics: an observation of Landau levels for optical photons

    Science.gov (United States)

    Schine, Nathan; Ryou, Albert; Sommer, Ariel; Simon, Jonathan

    Creating photonic materials with nontrivial topological characteristics has seen burgeoning interest in recent years; however, a major route to topology, a magnetic field for continuum photons, has remained elusive. We present the first experimental realization of a bulk magnetic field for optical photons. By using a non-planar ring resonator, we induce an image rotation on each round trip through the resonator. This results in a Coriolis/Lorentz force and a centrifugal anticonfining force, the latter of which is cancelled by mirror curvature. Spatial- and energy- resolved spectroscopy tracks photonic eigenstates as residual trapping is reduced, and we observe photonic Landau levels as the eigenstates become degenerate. We will discuss the conical geometry of the resulting manifold for photon dynamics and present a measurement of the local density of states that is consistent with Landau levels on a cone. While our work already demonstrates an integer quantum Hall material composed of photons, we have ensured compatibility with strong photon-photon interactions, which will allow quantum optical studies of entanglement and correlation in manybody systems including fractional quantum Hall fluids. This work was supported by DOE, DARPA, and AFOSR.

  17. Free-space coherent optical communication with orbital angular, momentum multiplexing/demultiplexing using a hybrid 3D photonic integrated circuit.

    Science.gov (United States)

    Guan, Binbin; Scott, Ryan P; Qin, Chuan; Fontaine, Nicolas K; Su, Tiehui; Ferrari, Carlo; Cappuzzo, Mark; Klemens, Fred; Keller, Bob; Earnshaw, Mark; Yoo, S J B

    2014-01-13

    We demonstrate free-space space-division-multiplexing (SDM) with 15 orbital angular momentum (OAM) states using a three-dimensional (3D) photonic integrated circuit (PIC). The hybrid device consists of a silica planar lightwave circuit (PLC) coupled to a 3D waveguide circuit to multiplex/demultiplex OAM states. The low excess loss hybrid device is used in individual and two simultaneous OAM states multiplexing and demultiplexing link experiments with a 20 Gb/s, 1.67 b/s/Hz quadrature phase shift keyed (QPSK) signal, which shows error-free performance for 379,960 tested bits for all OAM states.

  18. Optical coherence tomography: Technique and applications

    DEFF Research Database (Denmark)

    Thomsen, Jakob Borup; Sander, Birgit; Mogensen, Mette;

    2009-01-01

    Optical coherence tomography (OCT) is a noninvasive optical imaging modality providing real-time video rate images in two and three dimensions of biological tissues with micrometer resolution. OCT fills the gap between ultrasound and confocal microscopy, since it has a higher resolution than ultr...... of retinal diseases. The potential of OCT in many other applications is currently being explored, such as in developmental biology, skin cancer diagnostics, vulnerable plaque detection in cardiology, esophageal diagnostics and a number of other applications within oncology....

  19. Increasing entanglement between Gaussian states by coherent photon subtraction.

    Science.gov (United States)

    Ourjoumtsev, Alexei; Dantan, Aurélien; Tualle-Brouri, Rosa; Grangier, Philippe

    2007-01-19

    We experimentally demonstrate that the entanglement between Gaussian entangled states can be increased by non-Gaussian operations. Coherent subtraction of single photons from Gaussian quadrature-entangled light pulses, created by a nondegenerate parametric amplifier, produces delocalized states with negative Wigner functions and complex structures more entangled than the initial states in terms of negativity. The experimental results are in very good agreement with the theoretical predictions.

  20. Increasing entanglement between Gaussian states by coherent photon subtraction

    CERN Document Server

    Ourjoumtsev, A; Tualle-Brouri, R; Grangier, P; Ourjoumtsev, Alexei; Dantan, Aurelien; Tualle-Brouri, Rosa; Grangier, Philippe

    2006-01-01

    We experimentally demonstrate that the entanglement between Gaussian entangled states can be increased by non-Gaussian operations. Coherent subtraction of single photons from Gaussian quadrature-entangled light pulses, created by a non-degenerate parametric amplifier, produces delocalized "Schroedinger kitten" states with complex negative Wigner functions, more entangled than the initial states in terms of negativity. The experimental results are in very good agreement with the theoretical predictions.

  1. Application of optical coherence tomography based microangiography for cerebral imaging

    Science.gov (United States)

    Baran, Utku; Wang, Ruikang K.

    2016-03-01

    Requirements of in vivo rodent brain imaging are hard to satisfy using traditional technologies such as magnetic resonance imaging and two-photon microscopy. Optical coherence tomography (OCT) is an emerging tool that can easily reach at high speeds and provide high resolution volumetric images with a relatively large field of view for rodent brain imaging. Here, we provide the overview of recent developments of functional OCT based imaging techniques for neuroscience applications on rodents. Moreover, a summary of OCT-based microangiography (OMAG) studies for stroke and traumatic brain injury cases on rodents are provided.

  2. Requirement of optical coherence for continuous-variable quantum teleportation.

    Science.gov (United States)

    Rudolph, T; Sanders, B C

    2001-08-13

    We show that the sender and the receiver each require coherent devices in order to achieve unconditional continuous variable quantum teleportation (CVQT), and this requirement cannot be achieved with conventional laser sources, linear optics, ideal photon detectors, and perfect Fock state sources. The appearance of successful CVQT in recent experiments is due to interpreting the measurement record fallaciously in terms of one preferred ensemble (or decomposition) of the correct density matrix describing the state. Our analysis is unrelated to technical problems such as laser phase drift or finite squeezing bandwidth.

  3. Evaluation of a cheap ultrasonic stage for light source coherence function measurement, optical coherence tomography, optical coherence microscopy, and dynamic focusing

    NARCIS (Netherlands)

    Krstajic, Nikola; Matcher, Stephen J.; Childs, David; Hogg, Richard; Smallwood, Rod; Steenbergen, Wiendelt; Andersen, Peter E.; Bouma, Brett E.

    2009-01-01

    We evaluate the performance of a cheap ultrasonic stage in setups related to optical coherence tomography. The stage was used in several configurations: 1) optical delay line in optical coherence tomography (OCT) setup; 2) as a delay line measuring coherence function of a low coherence source (e.g.

  4. Optical coherence tomography in conjunction with bronchoscopy

    Energy Technology Data Exchange (ETDEWEB)

    Rodrigues, Ascedio Jose; Takimura, Celso Kiyochi; Lemos Neto, Pedro Alves; Figueiredo, Viviane Rossi, E-mail: ascedio@gmail.com [Servico de Endoscopia Respiratoria, Hospital das Clinicas, Universidade de Sao Paulo (FM/USP), SP (Brazil)

    2012-07-01

    To evaluate the feasibility of and the potential for using optical coherence tomography in conjunction with conventional bronchoscopy in the evaluation of the airways. Methods: This was a pilot study based on an ex vivo experimental model involving three animals: one adult New Zealand rabbit and two Landrace pigs. An optical coherence tomography imaging catheter was inserted through the working channel of a flexible bronchoscope in order to reach the distal trachea of the animals. Images of the walls of the trachea were systematically taken along its entire length, from the distal to the proximal portion. Results: The imaging catheter was easily adapted to the working channel of the bronchoscope. High-resolution images of cross sections of the trachea were taken in real time, precisely delineating microstructures, such as the epithelium, submucosa, and cartilage, as well as the adventitia of the anterior and lateral tracheal walls. The corresponding layers of the epithelium, mucosa, and cartilage were clearly differentiated. The mucosa, submucosa, and trachealis muscle were clearly identified in the posterior wall. Conclusions: It is feasible to use an optical coherence tomography imaging catheter in combination with a flexible bronchoscope. Optical coherence tomography produces high resolution images that reveal the microanatomy of the trachea, including structures that are typically seen only on images produced by conventional histology. (author)

  5. Optical Coherence Tomography for Material Characterization

    NARCIS (Netherlands)

    Liu, P.

    2014-01-01

    Optical coherence tomography (OCT) is a non-invasive, contactless and high resolution imaging method, which allows the reconstruction of two or three dimensional depth-resolved images in turbid media. In the past 20 years, OCT has been extensively developed in the field of biomedical diagnostics, wh

  6. Gabor fusion master slave optical coherence tomography

    DEFF Research Database (Denmark)

    Cernat, Ramona; Bradu, Adrian; Israelsen, Niels Møller

    2017-01-01

    This paper describes the application of the Gabor filtering protocol to a Master/Slave (MS) swept source optical coherence tomography (SS)-OCT system at 1300 nm. The MS-OCT system delivers information from selected depths, a property that allows operation similar to that of a time domain OCT syst...

  7. Functional optical coherence tomography of pigmented lesions

    NARCIS (Netherlands)

    Wessels, R.; Bruin, de D.M.; Relyveld, G.N.; Faber, D.J.; Vincent, A.D.; Sanders, J.; Leeuwen, van T.G.; Ruers, T.J.M.

    2015-01-01

    Background Cutaneous melanomas are diagnosed worldwide in 231 130 patients per year. The sensitivity and specificity of melanoma diagnosis expresses the need for an additional diagnostic method. Optical coherence tomography (OCT) has shown that it allows morphological (qualitative) description of im

  8. Optical coherence tomography as a diagnostic tool

    CSIR Research Space (South Africa)

    Singh, A

    2011-07-01

    Full Text Available Optical Coherence Tomography (OCT) has been used in biomedical applications as a method to non-invasively detect changes occurring in tissue such as the detection of skin cancer. The effect of skin tone on detection of skin cancer has however...

  9. Dynamic Optical Coherence Tomography in Dermatology

    DEFF Research Database (Denmark)

    Ulrich, Martina; Themstrup, Lotte; De Carvalho, Nathalie

    2016-01-01

    Optical coherence tomography (OCT) represents a non-invasive imaging technology, which may be applied to the diagnosis of non-melanoma skin cancer and which has recently been shown to improve the diagnostic accuracy of basal cell carcinoma. Technical developments of OCT continue to expand the app...

  10. Multiple photon-echo rephasing of coherent matter waves

    Energy Technology Data Exchange (ETDEWEB)

    Pan, Ruizhi; Yue, Xuguang; Xu, Xia; Lu, Haichang; Zhou, Xiaoji, E-mail: xjzhou@pku.edu.cn

    2015-03-20

    We investigate the multiple photon echo processes in a Bose–Einstein condensate (BEC) with inhomogeneous momentum broadening. By applying Bragg pulses with adjusted frequency mismatch to induce multiple rephasing, the BEC satisfies the coherence condition for successive superradiance. The atomic system can be efficiently transferred to a high momentum state step by step and emits multiple photon echo signals. These echo signals as a sequence show increasing widths and descending peaks, reflecting a residual dephasing effect due to kinetic-energy phase discrepancy during the population inversions. Our work may contribute to the coherence maintenance for ultracold atomic gas in the quantum information area and the high-precision measurement of atomic momentum width. - Highlights: • A multipulse protocol to induce multiple photon echo rephasing of a BEC is proposed. • Our method is a new and efficient way to transfer the BEC to high momentum modes. • Our method can extend a BEC's coherence time. • The echo sequence is analyzed to study the residual dephasing effect. • The echo decaying is useful in high-precision measurement of BEC's momentum width.

  11. Spin squeezing, entanglement, and coherence in two driven, dissipative, nonlinear cavities coupled with single- and two-photon exchange

    OpenAIRE

    Müstecaplıoğlu, Özgür; Hardal, Ali Ümit

    2014-01-01

    We investigate spin squeezing, quantum entanglement, and second-order coherence in two coupled, driven, dissipative, nonlinear cavities. We compare these quantum statistical properties for the cavities coupled with either single- or two-photon exchange. Solving the quantum optical master equation of the system numerically in the steady state, we calculate the zero-time delay second-order correlation function for the coherent, genuine two-mode entanglement parameters, an optimal spin squeezing...

  12. Optical technologies for extreme-ultraviolet and soft X-ray coherent sources

    Energy Technology Data Exchange (ETDEWEB)

    Canova, Federico [Amplitude Technologies, Evry (France); Poletto, Luca (ed.) [National Research Council, Padova (Italy). Inst. of Photonics and Nanotechnology

    2015-07-01

    The book reviews the most recent achievements in optical technologies for XUV and X-ray coherent sources. Particular attention is given to free-electron-laser facilities, but also to other sources available at present, such as synchrotrons, high-order laser harmonics and X-ray lasers. The optical technologies relevant to each type of source are discussed. In addition, the main technologies used for photon handling and conditioning, namely multilayer mirrors, adaptive optics, crystals and gratings are explained. Experiments using coherent light received during the last decades a lot of attention for the X-ray regime. Strong efforts were taken for the realization of almost fully coherent sources, e.g. the free-electron lasers, both as independent sources in the femtosecond and attosecond regimes and as seeding sources for free-electron-lasers and X-ray gas lasers. In parallel to the development of sources, optical technologies for photon handling and conditioning of such coherent and intense X-ray beams advanced. New problems were faced for the realization of optical components of beamlines demanding to manage coherent X-ray photons, e.g. the preservation of coherence and time structure of ultra short pulses.

  13. Homodyne en face optical coherence tomography

    OpenAIRE

    Yaqoob, Zahid; Fingler, Jeff; Heng, Xin; Yang, Changhuei

    2006-01-01

    We demonstrate, for what we believe to be the first time, the use of a 3×3 fiber-optic coupler to realize a homodyne optical coherence tomography (OCT) system for en face imaging of highly scattering tissues and turbid media. The homodyne OCT setup exploits the inherent phase shifts between different output ports of a 3×3 fiber-optic coupler to extract amplitude information of a sample. Our homodyne en face OCT system features a measured resolution of 14 μm axially and 9.4 μm laterally with a...

  14. Observation of optical-fiber Kerr nonlinearity at the single-photon level

    CERN Document Server

    Matsuda, Nobuyuki; Mitsumori, Yasuyoshi; Kosaka, Hideo; Edamatsu, Keiichi; 10.1038/nphoton.2008.292

    2012-01-01

    Optical fibers have been enabling numerous distinguished applications involving the operation and generation of light, such as soliton transmission, light amplification, all-optical switching and supercontinuum generation. The active function of optical fibers in the quantum regime is expected to be applicable to ultralow-power all-optical signal processing and quantum information processing. Here we demonstrate the first experimental observation of optical nonlinearity at the single-photon level in an optical fiber. Taking advantage of large nonlinearity and managed dispersion of a photonic crystal fiber, we have successfully measured very small (10^(-7) ~ 10^(-8)) conditional phase shifts induced by weak coherent pulses that contain one or less than one photon per pulse on average. In spite of its tininess, the phase shift was measurable using much (~10^6 times) stronger coherent probe pulses than the pump pulses. We discuss the feasibility of quantum information processing using optical fibers, taking into...

  15. Coherent phonon optics in a chip with an electrically controlled active device.

    Science.gov (United States)

    Poyser, Caroline L; Akimov, Andrey V; Campion, Richard P; Kent, Anthony J

    2015-02-05

    Phonon optics concerns operations with high-frequency acoustic waves in solid media in a similar way to how traditional optics operates with the light beams (i.e. photons). Phonon optics experiments with coherent terahertz and sub-terahertz phonons promise a revolution in various technical applications related to high-frequency acoustics, imaging, and heat transport. Previously, phonon optics used passive methods for manipulations with propagating phonon beams that did not enable their external control. Here we fabricate a phononic chip, which includes a generator of coherent monochromatic phonons with frequency 378 GHz, a sensitive coherent phonon detector, and an active layer: a doped semiconductor superlattice, with electrical contacts, inserted into the phonon propagation path. In the experiments, we demonstrate the modulation of the coherent phonon flux by an external electrical bias applied to the active layer. Phonon optics using external control broadens the spectrum of prospective applications of phononics on the nanometer scale.

  16. Generation of high-photon flux-coherent soft x-ray radiation with few-cycle pulses.

    Science.gov (United States)

    Demmler, Stefan; Rothhardt, Jan; Hädrich, Steffen; Krebs, Manuel; Hage, Arvid; Limpert, Jens; Tünnermann, Andreas

    2013-12-01

    We present a tabletop source of coherent soft x-ray radiation with high-photon flux. Two-cycle pulses delivered by a fiber-laser-pumped optical parametric chirped-pulse amplifier operating at 180 kHz repetition rate are upconverted via high harmonic generation in neon to photon energies beyond 200 eV. A maximum photon flux of 1.3·10(8) photons/s is achieved within a 1% bandwidth at 125 eV photon energy. This corresponds to a conversion efficiency of ~10(-9), which can be reached due to a gas jet simultaneously providing a high target density and phase matching. Further scaling potential toward higher photon flux as well as higher photon energies are discussed.

  17. Extreme optical confinement in a slotted photonic crystal waveguide

    Energy Technology Data Exchange (ETDEWEB)

    Caër, Charles; Le Roux, Xavier; Cassan, Eric, E-mail: eric.cassan@u-psud.fr [Institut d' Électronique Fondamentale, Université Paris-Sud CNRS UMR 8622 Bat. 220, Centre scientifique d' Orsay, 91405 Orsay (France); Combrié, Sylvain, E-mail: sylvain.combrie@thalesgroup.com; De Rossi, Alfredo [Thales Research and Technology, 1 Av. Augustin Fresnel, 91767 Palaiseau (France)

    2014-09-22

    Using Optical Coherence Tomography, we measure the attenuation of slow light modes in slotted photonic crystal waveguides. When the group index is close to 20, the attenuation is below 300 dB cm{sup −1}. Here, the optical confinement in the empty slot is very strong, corresponding to an ultra-small effective cross section of 0.02 μm{sup 2}. This is nearly 10 times below the diffraction limit at λ = 1.5 μm, and it enables an effective interaction with a very small volume of functionalized matter.

  18. Lasers and holography an introduction to coherent optics

    CERN Document Server

    KOCK, Winston

    1972-01-01

    Science Study Series No. 39: Lasers and Holography: An Introduction to Coherent Optics focuses on the processes, methodologies, and techniques involved in optics, including wave diffraction and patterns, zone plates, holograms, and diffraction. The publication first ponders on holograms as wave patterns, coherence, and lasers. Topics include reflectors and resonators, natural line width, semiconductor lasers, reflectors and spatial coherence, energy conservation with reflectors, frequency coherence and stability, coherent waves from small sources, photographic grating, and properties o

  19. Optics for coherent X-ray applications

    Energy Technology Data Exchange (ETDEWEB)

    Yabashi, Makina, E-mail: yabashi@spring8.or.jp [RIKEN SPring-8 Center, Kouto 1-1-1, Sayo, Hyogo 679-5148 (Japan); Tono, Kensuke [Japan Synchrotron Radiation Research Institute (JASRI), Kouto 1-1-1, Sayo, Hyogo 679-5198 (Japan); Mimura, Hidekazu [The University of Tokyo, Hongo 7-3-1, Bunkyo-ku, Tokyo 113-8656 (Japan); Matsuyama, Satoshi; Yamauchi, Kazuto [Osaka University, 2-1 Yamada-oka, Suita, Osaka 565-0871 (Japan); Tanaka, Takashi; Tanaka, Hitoshi; Tamasaku, Kenji [RIKEN SPring-8 Center, Kouto 1-1-1, Sayo, Hyogo 679-5148 (Japan); Ohashi, Haruhiko; Goto, Shunji [Japan Synchrotron Radiation Research Institute (JASRI), Kouto 1-1-1, Sayo, Hyogo 679-5198 (Japan); Ishikawa, Tetsuya [RIKEN SPring-8 Center, Kouto 1-1-1, Sayo, Hyogo 679-5148 (Japan)

    2014-08-27

    Developments of optics for coherent X-ray applications and their role in diffraction-limited storage rings are described. Developments of X-ray optics for full utilization of diffraction-limited storage rings (DLSRs) are presented. The expected performance of DLSRs is introduced using the design parameters of SPring-8 II. To develop optical elements applicable to manipulation of coherent X-rays, advanced technologies on precise processing and metrology were invented. With propagation-based coherent X-rays at the 1 km beamline of SPring-8, a beryllium window fabricated with the physical-vapour-deposition method was found to have ideal speckle-free properties. The elastic emission machining method was utilized for developing reflective mirrors without distortion of the wavefronts. The method was further applied to production of diffraction-limited focusing mirrors generating the smallest spot size in the sub-10 nm regime. To enable production of ultra-intense nanobeams at DLSRs, a low-vibration cooling system for a high-heat-load monochromator and advanced diagnostic systems to characterize X-ray beam properties precisely were developed. Finally, new experimental schemes for combinative nano-analysis and spectroscopy realised with novel X-ray optics are discussed.

  20. Frequency-time coherence for all-optical sampling without optical pulse source

    Science.gov (United States)

    Preußler, Stefan; Raoof Mehrpoor, Gilda; Schneider, Thomas

    2016-09-01

    Sampling is the first step to convert an analogue optical signal into a digital electrical signal. The latter can be further processed and analysed by well-known electrical signal processing methods. Optical pulse sources like mode-locked lasers are commonly incorporated for all-optical sampling, but have several drawbacks. A novel approach for a simple all-optical sampling is to utilise the frequency-time coherence of each signal. The method is based on only using two coupled modulators driven with an electrical sine wave. Since no optical source is required, a simple integration in appropriate platforms, such as Silicon Photonics might be possible. The presented method grants all-optical sampling with electrically tunable bandwidth, repetition rate and time shift.

  1. Storage and recall of weak coherent optical pulses with an efficiency of 25%

    CERN Document Server

    Sabooni, M; Walther, A; Lin, N; Amari, A; Huang, M; Kröll, S

    2009-01-01

    We demonstrate experimentally a quantum memory scheme for the storage of weak coherent light pulses in an inhomogeneously broadened optical transition in a Pr^{3+}: YSO crystal at 2.1 K. Precise optical pumping using a frequency stable (about 1kHz linewidth) laser is employed to create a highly controllable Atomic Frequency Comb (AFC) structure. We report single photon storage and retrieval efficiencies of 25%, based on coherent photon echo type re-emission in the forward direction. The coherence property of the quantum memory is proved through interference between a super Gaussian pulse and the emitted echo. Backward retrieval of the photon echo emission has potential for increasing storage and recall efficiency.

  2. Optical coherence tomographic findings in optic nerve hypoplasia

    Directory of Open Access Journals (Sweden)

    Daruchi Moon

    2013-01-01

    Full Text Available We investigated a case of unilateral optic nerve hypoplasia using spectral domain optical coherence tomography (SDOCT. Optical coherence tomography was done on both eyes using 5-line Raster scan for the fovea to analyze the retinal nerve fiber layer thickness, inner retinal layer thickness, outer retinal layer thickness, and optic disc cube scan for the disc. Retinal nerve fiber layer thickness, inner retinal layer thickness, and outer retinal layer thickness were manually measured at 21-points of each five lines, and results were compared between both eyes. Retinal nerve fiber layer thickness and inner retinal layer thickness of optic nerve hypoplasia were significantly thinner than the opposite eye, but there was no significant difference in the thickness of the outer retinal layer between both eyes.

  3. PLANAR OPTICAL WAVEGUIDES WITH PHOTONIC CRYSTAL STRUCTURE

    DEFF Research Database (Denmark)

    2003-01-01

    Planar optical waveguide comprising a core region and a cladding region comprising a photonic crystal material, said photonic crystal material having a lattice of column elements, wherein at least a number of said column elements are elongated substantially in an axial direction for said core reg...

  4. Optical experiments on 3D photonic crystals

    NARCIS (Netherlands)

    Koenderink, F.; Vos, W.

    2003-01-01

    Photonic crystals are optical materials that have an intricate structure with length scales of the order of the wavelength of light. The flow of photons is controlled in a manner analogous to how electrons propagate through semiconductor crystals, i.e., by Bragg diffraction and the formation of band

  5. Photonic aided bandpass sampling in coherent phase modulated radio-over-fiber links

    Science.gov (United States)

    Cao, Minghua; Li, Jianqiang; Dai, Jian; Dai, Yitang; Yin, Feifei; Zhou, Yue; Xu, Kun

    2016-06-01

    We have experimentally presented a digital coherent receiver employing photonic aided bandpass sampling technology for phase-modulated radio-over-fiber (RoF) links. An optical intensity modulator (IM) is utilized as the bandpass sampler which performs encoded on-off keyed pulse sequence on the optical local oscillator. Quaternary Phase Shift Keying (QPSK) modulated data signal with 20 MHz bandwidth at 5.2 GHz, 10.2 GHz and 15.2 GHz RF carrier frequency is experimentally demonstrated to be successfully detected by using balanced photodiodes (BPDs) with only 800 MHz analog bandwidth. It demonstrates that the required analog bandwidth of BPDs and ADCs can be dramatically reduced in a direct sampled coherent RoF communications system.

  6. High photon flux table-top coherent extreme ultraviolet source

    CERN Document Server

    Hädrich, Steffen; Rothhardt, Jan; Krebs, Manuel; Hoffmann, Armin; Pronin, Oleg; Pervak, Vladimir; Limpert, Jens; Tünnermann, Andreas

    2014-01-01

    High harmonic generation (HHG) enables extreme ultraviolet radiation with table-top setups. Its exceptional properties, such as coherence and (sub)-femtosecond pulse durations, have led to a diversity of applications. Some of these require a high photon flux and megahertz repetition rates, e.g. to avoid space charge effects in photoelectron spectroscopy. To date this has only been achieved with enhancement cavities. Here, we establish a novel route towards powerful HHG sources. By achieving phase-matched HHG of a megahertz fibre laser we generate a broad plateau (25 eV - 40 eV) of strong harmonics, each containing more than $10^{12}$ photons/s, which constitutes an increase by more than one order of magnitude in that wavelength range. The strongest harmonic (H25, 30 eV) has an average power of 143 $\\mu$W ($3\\cdot10^{13}$ photons/s). This concept will greatly advance and facilitate applications in photoelectron or coincidence spectroscopy, coherent diffractive imaging or (multidimensional) surface science.

  7. All-optical initialization, readout, and coherent preparation of single silicon-vacancy spins in diamond.

    Science.gov (United States)

    Rogers, Lachlan J; Jahnke, Kay D; Metsch, Mathias H; Sipahigil, Alp; Binder, Jan M; Teraji, Tokuyuki; Sumiya, Hitoshi; Isoya, Junichi; Lukin, Mikhail D; Hemmer, Philip; Jelezko, Fedor

    2014-12-31

    The silicon-vacancy (SiV-) color center in diamond has attracted attention because of its unique optical properties. It exhibits spectral stability and indistinguishability that facilitate efficient generation of photons capable of demonstrating quantum interference. Here we show optical initialization and readout of electronic spin in a single SiV- center with a spin relaxation time of T1=2.4±0.2  ms. Coherent population trapping (CPT) is used to demonstrate coherent preparation of dark superposition states with a spin coherence time of T2⋆=35±3  ns. This is fundamentally limited by orbital relaxation, and an understanding of this process opens the way to extend coherence by engineering interactions with phonons. Hyperfine structure is observed in CPT measurements with the 29Si isotope which allows access to nuclear spin. These results establish the SiV- center as a solid-state spin-photon interface.

  8. Ultrahigh Resolution Optical Coherence Tomography

    Science.gov (United States)

    Drexler, Wolfgang; Chen, Yu; Aguirre, Aaron D.; Považay, Boris; Unterhuber, Angelika; Fujimoto, James G.

    Since its invention in the late 1980s [1-4] and early 1990s [5-7], the original idea of OCT was to enable noninvasive optical biopsy, i.e., the in situ imaging of tissue microstructure with a resolution approaching that of histology, but without the need for tissue excision and post-processing. An important advance toward this goal was the introduction of ultrahigh-resolution OCT (UHR OCT). By improving axial OCT resolution by one order of magnitude from the 10 to 15 μm to the sub-μm region [8-11], UHR OCT enables superior visualization of tissue microstructure, including all major intraretinal layers in ophthalmic applications as well as cellular resolution OCT imaging in nontransparent tissue. This chapter reviews state-of-the-art technology that enables ultrahigh-resolution OCT covering the entire wavelength region from 500 to 1,600 nm and discusses fundamental limitations of OCT image resolution.

  9. Optical Coherence Tomography Velocimetry with Complex Fluids

    Science.gov (United States)

    Malm, A.; Waigh, T. A.; Jaradat, S.; Tomlin, R.

    2015-04-01

    We present recent results obtained with an Optical Coherence Tomography Velocimetry technique. An optical interferometer measures the velocity of a sheared fluid at specific depths of the sample using the coherence length of the light source. The technique allows the dynamics of 3 pico liter volumes to be probed inside opaque complex fluids. In a study of opaque starch suspensions, classical bulk rheology experiments show non-linear shear thickening, whereas observations of the velocity profiles as a function of distance across the gap show Newtonian behavior. The ability of the technique to measure velocity fluctuations is also discussed for the case of polyacrylamide samples which were observed to display shear banding behavior. A relationship between the viscoelasticity of the sample and the size of the apparent fluctuations is observed.

  10. High performance photonic reservoir computer based on a coherently driven passive cavity

    CERN Document Server

    Vinckier, Quentin; Smerieri, Anteo; Vandoorne, Kristof; Bienstman, Peter; Haelterman, Marc; Massar, Serge

    2015-01-01

    Reservoir computing is a recent bio-inspired approach for processing time-dependent signals. It has enabled a breakthrough in analog information processing, with several experiments, both electronic and optical, demonstrating state-of-the-art performances for hard tasks such as speech recognition, time series prediction and nonlinear channel equalization. A proof-of-principle experiment using a linear optical circuit on a photonic chip to process digital signals was recently reported. Here we present the first implementation of a photonic reservoir computer based on a coherently driven passive fiber cavity processing analog signals. Our experiment surpasses all previous experiments on a wide variety of tasks, and also has lower power consumption. Furthermore, the analytical model describing our experiment is also of interest, as it arguably constitutes the simplest high performance reservoir computer algorithm introduced so far. The present experiment, given its remarkable performances, low energy consumption...

  11. The Choroid and Optical Coherence Tomography

    OpenAIRE

    Taha Sezer; Muhammet Altınışık; İbrahim Arif Koytak

    2016-01-01

    The choroid is the most vascular tissue in the eye and it plays an important role in the pathophysiology of various common chorioretinal diseases such as central serous retinopathy, age-related macular degeneration and degenerative myopia. Quantitative assessment of the choroid has been quite challenging with traditional imaging modalities such as indocyanine green angiography and ultrasonography due to limited resolution and repeatability. With the advent of optical coherence tomography (OCT...

  12. Two-Photon Micromaser with Initial Atomic Coherence

    Institute of Scientific and Technical Information of China (English)

    SUN Wei-Hui; DU Si-De; CHEN Xiao-Shuang

    2005-01-01

    @@ We investigate the quantum dynamics ora two-photon micromaser pumped by atoms injected in the superpositionstate of the upper and intermediate levels. We simulate a master equation governing the system by the MonteCarlo wavefunction approach and analyse the steady-state behaviour as a function of the atomic transit time.The atomic coherence can effectively enhance the intensity and sub-Poissonian of the cavity field as comparedwith the atomic mixture. It is also discovered that the phase of the cavity field can be shifted by adjusting thedetuning between the atom and field. This result shows that it is possible to manipulate the phase of the cavityfield by detuning, due to atomic coherence.

  13. Coherent scattering of high-energy photon in a medium

    CERN Document Server

    Baier, V N

    2001-01-01

    The coherent scattering of photon in the Coulomb field (the Delbr\\"uck scattering) is considered for the momentum transfer $\\Delta \\ll m$ in the frame of the quasiclassical operator method. In high-energy region this process occurs over rather long distance. The process amplitude is calculated taking into account the multiple scattering of particles of the intermediate electron-positron pair in a medium. The result is the suppression of the process. Limiting cases of weak and strong effects of the multiple scattering are analyzed. The approach used is the generalization of the method developed by authors for consideration of the Landau-Pomeranchuk-Migdal effect.

  14. Angular Distribution of Photons in Coherent Bremsstrahlung in Deformed Crystals

    CERN Document Server

    Parazian, V V

    2010-01-01

    We investigate the angular distribution of photons in the coherent bremsstrahlung process by high-energy electrons in a periodically deformed single crystal with a complex base. The formula for the corresponding differential cross-section is derived for an arbitrary deformation field. The case is considered in detail when the electron enters into the crystal at small angles with respect to a crystallographic axis. The results of the numerical calculations are presented for SiO2 single crystal and Moliere parameterization of the screened atomic potentials in the case of the deformation field generated by the acoustic wave of S -type.

  15. Optical microscope using an interferometric source of two-color, two-beam entangled photons

    Science.gov (United States)

    Dress, William B.; Kisner, Roger A.; Richards, Roger K.

    2004-07-13

    Systems and methods are described for an optical microscope using an interferometric source of multi-color, multi-beam entangled photons. A method includes: downconverting a beam of coherent energy to provide a beam of multi-color entangled photons; converging two spatially resolved portions of the beam of multi-color entangled photons into a converged multi-color entangled photon beam; transforming at least a portion of the converged multi-color entangled photon beam by interaction with a sample to generate an entangled photon specimen beam; and combining the entangled photon specimen beam with an entangled photon reference beam within a single beamsplitter. An apparatus includes: a multi-refringent device providing a beam of multi-color entangled photons; a condenser device optically coupled to the multi-refringent device, the condenser device converging two spatially resolved portions of the beam of multi-color entangled photons into a converged multi-color entangled photon beam; a beam probe director and specimen assembly optically coupled to the condenser device; and a beam splitter optically coupled to the beam probe director and specimen assembly, the beam splitter combining an entangled photon specimen beam from the beam probe director and specimen assembly with an entangled photon reference beam.

  16. Polarization Drift Channel Model for Coherent Fibre-Optic Systems

    CERN Document Server

    Czegledi, Cristian B; Agrell, Erik; Johannisson, Pontus

    2015-01-01

    A theoretical framework is introduced to model the dynamical changes of the state of polarization during transmission in coherent fibre-optic systems. The model generalizes the one-dimensional phase noise random walk to higher dimensions, accounting for random polarization drifts. The model is described in the Jones, Stokes and real 4-dimensional formalisms, and the mapping between them is derived. Such a model will be increasingly important in simulating and optimizing future optical systems, which to a higher and higher degree rely on transmission and detection on both polarizations jointly using sophisticated digital signal processing. Such analysis cannot be carried out using the more rudimentary polarization drift models in use today, which only account for deterministic effects. The proposed polarization drift model is the first of its kind and will likely be useful in a wide-range of photonics applications where stochastic polarization fluctuation is an issue.

  17. Gauss-Bonnet gravity, relic coherent gravitons and optical chaos

    CERN Document Server

    Crowell, Lawrence B

    2011-01-01

    We discuss the production of massive relic coherent gravitons in Gauss-Bonnet gravity and their possible imprint in Cosmic Microwave Background. In fact, in the very early universe these relic gravitons could have acted as slow gravity waves. They may have then acted to focus the geodesics of radiation and matter. Therefore, their imprint on the later evolution of the universe could appear as filaments and domain wall in the Universe today. In that case, the effect on Cosmic Microwave Background should be analogous to the effect of water waves, which, in focusing light, create optical caustics which are commonly seen on the bottom of swimming pools. We analyze this important issue by showing how relic massive GWs perturb the trajectories of Cosmic Microwave Background photons (gravitational lensing by relic GWs). The consequence of the type of physics discussed is outlined by illustrating an amplification of what might be called optical chaos.

  18. Photonic nanowires for quantum optics

    DEFF Research Database (Denmark)

    Munsch, M.; Claudon, J.; Bleuse, J.;

    Photonic nanowires (PWs) are simple dielectric structures for which a very efficient and broadband spontaneous emission (SE) control has been predicted [1]. Recently, a single photon source featuring a record high efficiency was demonstrated using this geometry [2]. Using time-resolved micro......-photoluminescence, we investigate directly the SE of single InAs quantum dots (QDs) embedded in GaAs PWs and demonstrate performances that fully confirm the theoretical predictions [3]. In addition, we discuss recent results obtained on elliptical wires that ensure an efficient control of the photon polarization [4......, equivalent to the one obtained in state-of-the-art 2D photonic crystals, is measured. Moreover, a PW featuring an elliptical section provides a very efficient control over the polarization of the emitted photon. In that case, only one guided mode, with a linear polarization oriented along the major axis...

  19. Harnessing optical forces in integrated photonic circuits.

    Science.gov (United States)

    Li, Mo; Pernice, W H P; Xiong, C; Baehr-Jones, T; Hochberg, M; Tang, H X

    2008-11-27

    The force exerted by photons is of fundamental importance in light-matter interactions. For example, in free space, optical tweezers have been widely used to manipulate atoms and microscale dielectric particles. This optical force is expected to be greatly enhanced in integrated photonic circuits in which light is highly concentrated at the nanoscale. Harnessing the optical force on a semiconductor chip will allow solid state devices, such as electromechanical systems, to operate under new physical principles. Indeed, recent experiments have elucidated the radiation forces of light in high-finesse optical microcavities, but the large footprint of these devices ultimately prevents scaling down to nanoscale dimensions. Recent theoretical work has predicted that a transverse optical force can be generated and used directly for electromechanical actuation without the need for a high-finesse cavity. However, on-chip exploitation of this force has been a significant challenge, primarily owing to the lack of efficient nanoscale mechanical transducers in the photonics domain. Here we report the direct detection and exploitation of transverse optical forces in an integrated silicon photonic circuit through an embedded nanomechanical resonator. The nanomechanical device, a free-standing waveguide, is driven by the optical force and read out through evanescent coupling of the guided light to the dielectric substrate. This new optical force enables all-optical operation of nanomechanical systems on a CMOS (complementary metal-oxide-semiconductor)-compatible platform, with substantial bandwidth and design flexibility compared to conventional electrical-based schemes.

  20. Smart optical coherence tomography for ultra-deep imaging through highly scattering media

    CERN Document Server

    Badon, Amaury; Lerosey, Geoffroy; Boccara, Albert C; Fink, Mathias; Aubry, Alexandre

    2015-01-01

    Multiple scattering of waves in disordered media is a nightmare whether it be for detection or imaging purposes. The best approach so far to get rid of multiple scattering is optical coherence tomography. It basically combines confocal microscopy and coherence time-gating to discriminate ballistic photons from a predominant multiple scattering background. Nevertheless, the imaging depth range remains limited to 1 mm at best in human soft tissues. Here we propose a matrix approach of optical imaging to push back this fundamental limit. By combining a matrix discrimination of ballistic waves and iterative time-reversal, we show both theoretically and experimentally an extension of the imaging-depth limit by at least a factor two compared to optical coherence tomography. In particular, the reported experiment demonstrates imaging through a strongly scattering layer from which only one reflected photon over 1000 billion is ballistic. This approach opens a new route towards ultra-deep tissue imaging.

  1. Frequency-time coherence for all-optical sampling without optical pulse source

    CERN Document Server

    Preussler, Stefan; Schneider, Thomas

    2016-01-01

    Sampling is the first step to convert an analogue optical signal into a digital electrical signal. The latter can be further processed and analysed by well-known electrical signal processing methods. Optical pulse sources like mode-locked lasers are commonly incorporated for all-optical sampling, but have several drawbacks. A novel approach for a simple all-optical sampling is to utilise the frequency-time coherence of each signal. The method is based on only using two coupled modulators driven with an electrical sine wave, allowing simple integration in appropriate platforms, such as Silicon Photonics. The presented method grants all-optical sampling with electrically tunable bandwidth, repetition rate and time shift.

  2. Optical devices based on liquid crystal photonic bandgap fibers

    DEFF Research Database (Denmark)

    Alkeskjold, Thomas Tanggaard

    2005-01-01

    In this ph.d. work, an experimental and theoretical study on Liquid Crystal (LC) infiltrated Photonic Crystal Fibers (PCFs) has been carried out. PCFs usually, consists of an air/silica microstructure of air holes arranged in a triangular lattice surrounding a core defect defined by a missing air...... hole. The presence of a LC in the holes of the PCF transforms the fiber from a Total Internal Reflection (TIR) guiding type into a Photonic BandGap (PBG) guiding type, where light is confined to the silica core by coherent scattering from the LC-billed holes. The high dielectric and optical anisotropy...... of LCs combined with the unique waveguiding features of PBG fibers gives the LC filled PCFs unique tunable properties. PBG guidance has been demonstrated for different mesophases of LCs and various functional compact fibers has been demonstrated, which utilitzes the high thermo-optical and electro...

  3. Coherent coupling between radio frequency, optical, and acoustic waves in piezo-optomechanical circuits

    CERN Document Server

    Balram, Krishna C; Song, Jin Dong; Srinivasan, Kartik

    2015-01-01

    The interaction of optical and mechanical modes in nanoscale optomechanical systems has been widely studied for applications ranging from sensing to quantum information science. Here, we develop a platform for cavity optomechanical circuits in which localized and interacting 1550 nm photons and 2.4 GHz phonons are combined with photonic and phononic waveguides. Working in GaAs facilitates manipulation of the localized mechanical mode either with a radio frequency field through the piezo-electric effect, or optically through the strong photoelastic effect. We use this to demonstrate a novel acoustic wave interference effect, analogous to coherent population trapping in atomic systems, in which the coherent mechanical motion induced by the electrical drive can be completely cancelled out by the optically-driven motion. The ability to manipulate cavity optomechanical systems with equal facility through either photonic or phononic channels enables new device and system architectures for signal transduction betwee...

  4. Coherent coupling between radio frequency, optical, and acoustic waves in piezo-optomechanical circuits.

    Science.gov (United States)

    Balram, Krishna C; Davanço, Marcelo I; Song, Jin Dong; Srinivasan, Kartik

    2016-05-01

    Optomechanical cavities have been studied for applications ranging from sensing to quantum information science. Here, we develop a platform for nanoscale cavity optomechanical circuits in which optomechanical cavities supporting co-localized 1550 nm photons and 2.4 GHz phonons are combined with photonic and phononic waveguides. Working in GaAs facilitates manipulation of the localized mechanical mode either with a radio frequency (RF) field through the piezo-electric effect, which produces acoustic waves that are routed and coupled to the optomechanical cavity by phononic crystal waveguides, or optically through the strong photoelastic effect. Along with mechanical state preparation and sensitive readout, we use this to demonstrate an acoustic wave interference effect, similar to atomic coherent population trapping, in which RF-driven coherent mechanical motion is cancelled by optically-driven motion. Manipulating cavity optomechanical systems with equal facility through both photonic and phononic channels enables new architectures for signal transduction between the optical, electrical, and mechanical domains.

  5. Mitigating Photon Jitter in Optical PPM Communication

    Science.gov (United States)

    Moision, Bruce

    2008-01-01

    A theoretical analysis of photon-arrival jitter in an optical pulse-position-modulation (PPM) communication channel has been performed, and now constitutes the basis of a methodology for designing receivers to compensate so that errors attributable to photon-arrival jitter would be minimized or nearly minimized. Photon-arrival jitter is an uncertainty in the estimated time of arrival of a photon relative to the boundaries of a PPM time slot. Photon-arrival jitter is attributable to two main causes: (1) receiver synchronization error [error in the receiver operation of partitioning time into PPM slots] and (2) random delay between the time of arrival of a photon at a detector and the generation, by the detector circuitry, of a pulse in response to the photon. For channels with sufficiently long time slots, photon-arrival jitter is negligible. However, as durations of PPM time slots are reduced in efforts to increase throughputs of optical PPM communication channels, photon-arrival jitter becomes a significant source of error, leading to significant degradation of performance if not taken into account in design. For the purpose of the analysis, a receiver was assumed to operate in a photon- starved regime, in which photon counts follow a Poisson distribution. The analysis included derivation of exact equations for symbol likelihoods in the presence of photon-arrival jitter. These equations describe what is well known in the art as a matched filter for a channel containing Gaussian noise. These equations would yield an optimum receiver if they could be implemented in practice. Because the exact equations may be too complex to implement in practice, approximations that would yield suboptimal receivers were also derived.

  6. Integrated optical devices for photonics instrumentation systems

    Energy Technology Data Exchange (ETDEWEB)

    McWright, G.M.; Lafaw, D.A.; Lowry, M.; Tindall, W.

    1990-01-01

    We discuss the design, fabrication, and evaluation of high speed integrated optical devices for application to photonics instrumentation systems. Specifically, we have demonstrated integrated optical devices with bandwidths in excess of 25 GHz and implemented these devices in single-shot, streak camera based recording schemes. 5 refs., 6 figs.

  7. Photonic crystal nanostructures for optical biosensing applications

    DEFF Research Database (Denmark)

    Dorfner, D.; Zabel, T.; Hürlimann, T.;

    2009-01-01

    We present the design, fabrication and optical investigation of photonic crystal (PhC) nanocavity drop filters for use as optical biosensors. The resonant cavity mode wavelength and Q-factor are studied as a function of the ambient refractive index and as a function of adsorbed proteins (bovine s...

  8. Picosecond Photon Echoes Detected by Optical Mixing

    NARCIS (Netherlands)

    Hesselink, Wim H.; Wiersma, Douwe A.

    1978-01-01

    Picosecond photon echoes are shown to be easily detected by optical mixing. The synchronized picosecond excitation and probe pulses are generated by amplifying pulses from two dye lasers, synchronously pumped by a mode-locked argon-ion laser. The technique is used to study optical dephasing in the o

  9. Interfacing superconducting qubits and single optical photons

    NARCIS (Netherlands)

    Das, Sumanta; Faez, Sanli; Sørensen, Anders S.

    2016-01-01

    We propose an efficient light-matter interface at optical frequencies between a superconducting qubit and a single photon. The desired interface is based on a hybrid architecture composed of an organic molecule embedded inside an optical waveguide and electrically coupled to a superconducting qubit

  10. Quantum-coherent coupling of a mechanical oscillator to an optical cavity mode.

    Science.gov (United States)

    Verhagen, E; Deléglise, S; Weis, S; Schliesser, A; Kippenberg, T J

    2012-02-01

    Optical laser fields have been widely used to achieve quantum control over the motional and internal degrees of freedom of atoms and ions, molecules and atomic gases. A route to controlling the quantum states of macroscopic mechanical oscillators in a similar fashion is to exploit the parametric coupling between optical and mechanical degrees of freedom through radiation pressure in suitably engineered optical cavities. If the optomechanical coupling is 'quantum coherent'--that is, if the coherent coupling rate exceeds both the optical and the mechanical decoherence rate--quantum states are transferred from the optical field to the mechanical oscillator and vice versa. This transfer allows control of the mechanical oscillator state using the wide range of available quantum optical techniques. So far, however, quantum-coherent coupling of micromechanical oscillators has only been achieved using microwave fields at millikelvin temperatures. Optical experiments have not attained this regime owing to the large mechanical decoherence rates and the difficulty of overcoming optical dissipation. Here we achieve quantum-coherent coupling between optical photons and a micromechanical oscillator. Simultaneously, coupling to the cold photon bath cools the mechanical oscillator to an average occupancy of 1.7 ± 0.1 motional quanta. Excitation with weak classical light pulses reveals the exchange of energy between the optical light field and the micromechanical oscillator in the time domain at the level of less than one quantum on average. This optomechanical system establishes an efficient quantum interface between mechanical oscillators and optical photons, which can provide decoherence-free transport of quantum states through optical fibres. Our results offer a route towards the use of mechanical oscillators as quantum transducers or in microwave-to-optical quantum links.

  11. Functional Doppler optical coherence tomography for cortical blood flow imaging

    Science.gov (United States)

    Yu, Lingfeng; Liu, Gangjun; Nguyen, Elaine; Choi, Bernard; Chen, Zhongping

    2010-02-01

    Optical methods have been widely used in basic neuroscience research to study the cerebral blood flow dynamics in order to overcome the low spatial resolution associated with magnetic resonance imaging and positron emission tomography. Although laser Doppler imaging and laser speckle imaging can map out en face cortical hemodynamics and columns, depth resolution is not available. Two-photon microscopy has been used for mapping cortical activity. However, flow measurement requires fluorescent dye injection, which can be problematic. The noninvasive and high resolution tomographic capabilities of optical coherence tomography make it a promising technique for mapping depth resolved cortical blood flow. Here, we present a functional Doppler optical coherence tomography (OCT) imaging modality for quantitative evaluation of cortical blood flow in a mouse model. Fast, repeated, Doppler OCT scans across a vessel of interest were performed to record flow dynamic information with a high temporal resolution of the cardiac cycles. Spectral Doppler analysis of continuous Doppler images demonstrates how the velocity components and longitudinally projected flow-volume-rate change over time, thereby providing complementary temporal flow information to the spatially distributed flow information of Doppler OCT. The proposed functional Doppler OCT imaging modality can be used to diagnose vessel stenosis/blockage or monitor blood flow changes due to pharmacological agents/neuronal activities. Non-invasive in-vivo mice experiments were performed to verify the capabilities of function Doppler OCT.

  12. Optical interference coatings for optics and photonics [Invited].

    Science.gov (United States)

    Lee, Cheng-Chung

    2013-01-01

    Optical interference coatings play as an important role in the progress in optics and photonics. In this article we give a minireview of the evolution of optical interference coatings from the theory, the design, to the manufacture. Some interesting but challenging topics for the future are also discussed.

  13. Optical trapping apparatus, methods and applications using photonic crystal resonators

    Science.gov (United States)

    Erickson, David; Chen, Yih-Fan

    2015-06-16

    A plurality of photonic crystal resonator optical trapping apparatuses and a plurality optical trapping methods using the plurality of photonic crystal resonator optical trapping apparatuses include located and formed over a substrate a photonic waveguide that is coupled (i.e., either separately coupled or integrally coupled) with a photonic crystal resonator. In a particular embodiment, the photonic waveguide and the photonic crystal resonator comprise a monocrystalline silicon (or other) photonic material absent any chemical functionalization. In another particular embodiment, the photonic waveguide and the photonic crystal resonator comprise a silicon nitride material which when actuating the photonic crystal resonator optical trapping apparatus with a 1064 nanometer resonant photonic radiation wavelength (or other resonant photonic radiation wavelength in a range from about 700 to about 1200 nanometers) provides no appreciable heating of an aqueous sample fluid that is analyzed by the photonic crystal resonator optical trapping apparatus.

  14. Optical coherence tomography findings of quinine poisoning

    Directory of Open Access Journals (Sweden)

    John Christoforidis

    2011-01-01

    Full Text Available John Christoforidis, Robert Ricketts, Theodore Loizos, Susie ChangThe Ohio State University College of Medicine, Columbus, OH, USAPurpose: To report a case of acute quinine poisoning, document acute and chronic macular changes with optical coherence tomography imaging and fluorescein angiography (FA, and to review the literature on ocular toxicity of quinine.Methods: A 32-year-old white female presented to our Emergency Department after ingesting over 7.5 g of quinine. She underwent a complete ophthalmologic examination, fluorescein angiography, Stratus time-domain optical coherence tomography (OCT, and electroretinography at 72 hours and 15 months postingestion. Stratus time-domain and Cirrus spectral-domain OCT, fundus autofluorescence, and FA were obtained at 28 months postingestion.Results: Fluorescein angiography at 72 hours postingestion revealed normal filling times and vasculature. OCT showed marked thickening of the inner retina bilaterally. At 15 and 28 months follow-up, fundus photography and fluorescein angiography demonstrated optic nerve pallor, severely attenuated retinal vessels while OCT showed inner retinal atrophy. Fundus autofluorescence did not reveal any retinal pigmentary abnormalities.Conclusions: Quinine toxicity as seen by OCT reveals increased thickness with inner retinal hyperreflectivity acutely with development of significant retinal atrophy in the long-term. Fundus autofluorescence reveals an intact retinal pigment epithelial layer at 28 months. These findings suggest that quinine poisoning may produce a direct toxic effect on the inner retina in the acute phase resulting in long-term retinal atrophy.Keywords: retinal, optical coherence tomography, quinine toxicity 

  15. Coherent beam control through inhomogeneous media in multi-photon microscopy

    Science.gov (United States)

    Paudel, Hari Prasad

    Multi-photon fluorescence microscopy has become a primary tool for high-resolution deep tissue imaging because of its sensitivity to ballistic excitation photons in comparison to scattered excitation photons. The imaging depth of multi-photon microscopes in tissue imaging is limited primarily by background fluorescence that is generated by scattered light due to the random fluctuations in refractive index inside the media, and by reduced intensity in the ballistic focal volume due to aberrations within the tissue and at its interface. We built two multi-photon adaptive optics (AO) correction systems, one for combating scattering and aberration problems, and another for compensating interface aberrations. For scattering correction a MEMS segmented deformable mirror (SDM) was inserted at a plane conjugate to the objective back-pupil plane. The SDM can pre-compensate for light scattering by coherent combination of the scattered light to make an apparent focus even at a depths where negligible ballistic light remains (i.e. ballistic limit). This problem was approached by investigating the spatial and temporal focusing characteristics of a broad-band light source through strongly scattering media. A new model was developed for coherent focus enhancement through or inside the strongly media based on the initial speckle contrast. A layer of fluorescent beads under a mouse skull was imaged using an iterative coherent beam control method in the prototype two-photon microscope to demonstrate the technique. We also adapted an AO correction system to an existing in three-photon microscope in a collaborator lab at Cornell University. In the second AO correction approach a continuous deformable mirror (CDM) is placed at a plane conjugate to the plane of an interface aberration. We demonstrated that this "Conjugate AO" technique yields a large field-of-view (FOV) advantage in comparison to Pupil AO. Further, we showed that the extended FOV in conjugate AO is maintained over a

  16. Dental diagnostics using optical coherence techniques

    Energy Technology Data Exchange (ETDEWEB)

    Nathel, H. [Lawrence Livermore National Lab., CA (United States); Colston, B. [Univ. of California, San Francisco, CA (United States); Armitage, G. [Univ. of California, Davis, CA (United States)] [and others

    1994-11-15

    Optical radiation can be used for diagnostic purposes in oral medicine. However, due to the turbid, amorphous, and inhomogeneous nature of dental tissue conventional techniques used to transilluminate materials are not well suited to dental tissues. Optical coherence techniques either in the time- of frequency-domain offer the capabilities of discriminating scattered from unscattered light, thus allowing for imaging through turbid tissue. Currently, using optical time-domain reflectometry we are able to discriminate specular from diffuse reflections occurring at tissue boundaries. We have determined the specular reflectivity of enamel and dentin to be approximately 6.6 x 10{sup -5} and 1.3 x 10{sup -6}, respectively. Implications to periodontal imaging will be discussed.

  17. Research and Development for X-Ray Optics and Diagnostics on the Linac Coherent Source (LCLS)

    Energy Technology Data Exchange (ETDEWEB)

    Bionta, R M; Arthur, J; Chapman, H; Craig, B; Klingmann, J; Kuba, J; London, R A; Ott, L; Ryutov, D; Shepherd, R; Shlyaptsev, V; Wootton, A

    2002-09-24

    The Linac Coherent Light Source (LCLS) is a 1.5 to 15 {angstrom} wavelength Free-Electron Laser (PEL), under development at the Stanford Linear Accelerator Center (SLAC). The photon output consists of high brightness, transversely coherent pulses with duration < 300 fs, together with a broad spontaneous spectrum. The output energy density per unit area, pulse duration, repetition rate, and small FEL spot size pose special challenges for optical components and diagnostics downstream of the undulator. Planning for the photon beam transport, manipulation and diagnostics downstream of the undulator has begun.

  18. Coherent ultrafast measurement of time-bin encoded photons

    CERN Document Server

    Donohue, John M; Lavoie, Jonathan; Resch, Kevin J

    2013-01-01

    Time-bin encoding is a robust form of optical quantum information, especially for transmission in optical fibers. To read out the information, the separation of the time bins must be larger than the detector time resolution, typically on the order of nanoseconds for photon counters. In the present work, we demonstrate a technique using a nonlinear interaction between chirped entangled time-bin photons and shaped laser pulses to perform projective measurements on arbitrary time-bin states with picosecond-scale separations. We demonstrate a tomographically-complete set of time-bin qubit projective measurements and show the fidelity of operations is sufficiently high to violate the CHSH-Bell inequality by more than 6 standard deviations.

  19. Concept of coherence of learning physical optics

    Science.gov (United States)

    Colombo, Elisa M.; Jaen, Mirta; de Cudmani, Leonor C.

    1995-10-01

    The aim of the actual paper is to enhance achievements of the text 'Optica Fisica Basica: estructurada alrededor del concepto de coherencia luminosa' (in English 'Basic Physical Optics centered in the concept of coherence'). We consider that this book is a very worth tool when one has to learn or to teach some fundamental concepts of physical optics. It is well known that the topics of physical optics present not easy understanding for students. Even more they also present some difficulties for the teachers when they have to introduce them to the class. First, we think that different phenomena like diffraction and polarization could be well understood if the starting point is a deep comprehension of the concept of interference of light and, associated with this, the fundamental and nothing intuitive concept of coherence of the light. In the reference text the authors propose the use of expression 'stable interference pattern of no uniform intensity' instead of 'pattern of interference' and 'average pattern of uniform untested' instead of 'lack of interference' to make reference that light always interfere but just under restrictive conditions it can be got temporal and spatial stability of the pattern. Another idea we want to stand out is that the ability to observe a 'stable interference pattern of no uniform intensity' is associated not only with the coherence of the source but also with the dimensions of the experimental system and with the temporal and spatial characteristics of the detector used - human eye, photographic film, etc. The proposal is well support by quantitative relations. With an alternate model: a train of waves with a finite length of coherence, it is possible to get range of validity of models, to decide when a source could be considered a 'point' or 'monochromatic' or 'remote', an 'infinite' wave or a train of waves, etc. Using this concept it is possible to achieve a better understanding of phenomena like the polarization of light. Here, it

  20. Optics for coherent X-ray applications.

    Science.gov (United States)

    Yabashi, Makina; Tono, Kensuke; Mimura, Hidekazu; Matsuyama, Satoshi; Yamauchi, Kazuto; Tanaka, Takashi; Tanaka, Hitoshi; Tamasaku, Kenji; Ohashi, Haruhiko; Goto, Shunji; Ishikawa, Tetsuya

    2014-09-01

    Developments of X-ray optics for full utilization of diffraction-limited storage rings (DLSRs) are presented. The expected performance of DLSRs is introduced using the design parameters of SPring-8 II. To develop optical elements applicable to manipulation of coherent X-rays, advanced technologies on precise processing and metrology were invented. With propagation-based coherent X-rays at the 1 km beamline of SPring-8, a beryllium window fabricated with the physical-vapour-deposition method was found to have ideal speckle-free properties. The elastic emission machining method was utilized for developing reflective mirrors without distortion of the wavefronts. The method was further applied to production of diffraction-limited focusing mirrors generating the smallest spot size in the sub-10 nm regime. To enable production of ultra-intense nanobeams at DLSRs, a low-vibration cooling system for a high-heat-load monochromator and advanced diagnostic systems to characterize X-ray beam properties precisely were developed. Finally, new experimental schemes for combinative nano-analysis and spectroscopy realised with novel X-ray optics are discussed.

  1. Coherent optical array receiver for PPM signals under atmospheric turbulence

    Science.gov (United States)

    Munoz Fernandez, Michela

    The performance of a coherent free-space optical communications system operating in the presence of turbulence is investigated. Maximum Likelihood Detection techniques are employed to optimally detect Pulse Position Modulated signals with a focal-plane detector array and to reconstruct the turbulence-degraded signals. Laboratory equipment and experimental setup used to carry out these experiments at the Jet Propulsion Laboratory are described. The key components include two lasers operating at 1064 nm wavelength for use with coherent detection, a 16 element (4 X 4) InGaAs focal-plane detector array, and a data-acquisition and signal-processing assembly needed to sample and collect the data and analyze the results. The detected signals are combined using the least-mean-square (LMS) algorithm. In the first part of the experimental results we show convergence of the algorithm for experimentally obtained signal tones in the presence of atmospheric turbulence. The second part of the experimental results shows adaptive combining of experimentally obtained heterodyned pulse position modulated (PPM) signals with pulse-to-pulse coherence in the presence of simulated spatial distortions resembling atmospheric turbulence. The adaptively combined PPM signals are phased up via an LMS algorithm suitably optimized to operate with PPM in the presence of additive shot noise. A convergence analysis of the algorithm is presented, and results with both computer-simulated and experimentally obtained PPM signals are analyzed. The third part of the experimental results, in which the main goal of this thesis is achieved, includes an investigation of the performance of the Coherent Optical Receiver Experiment (CORE) at JPL. Bit Error Rate (BER) results are presented for single and multichannel optical receivers where quasi shot noise-limited performance is achieved under simulated turbulence conditions using noncoherent postdetection processing techniques. Theoretical BER expressions are

  2. Optical properties of photonic crystals

    CERN Document Server

    Sakoda, Kazuaki

    2001-01-01

    The interaction between the radiation field and matter is the most fundamen­ tal source of dynamics in nature. It brings about the absorption and emission of photons, elastic and inelastic light scattering, the radiative lifetime of elec­ tronic excited states, and so on. The huge amount of energy carried from the sun by photons is the source of all activities of creatures on the earth. The absorption of photons by chlorophylls and the successive electronic excita­ tion initiate a series of chemical reactions that are known as photosynthesis, which support all life on the earth. Radiative energy is also the main source of all meteorological phenomena. The fundamentals of the radiation field and its interaction with matter were clarified by classical electromagnetism and quantum electrodynamics. These theories, we believe, explain all electromagnetic phenomena. They not only provide a firm basis for contemporary physics but also generate a vast range of technological applications. These include television, ...

  3. Optical coherence tomography investigations of ceramic lumineers

    Science.gov (United States)

    Fernandes, Luana O.; Graça, Natalia D. R. L.; Melo, Luciana S. A.; Silva, Claudio H. V.; Gomes, Anderson S. L.

    2016-02-01

    Lumineers are veneer laminates used as an alternative for aesthetic dental solutions of the highest quality, but the only current means of its performance assessment is visual inspection. The objective of this study was to use the Optical Coherence Tomography (OCT) technique working in spectral domain to analyze in vivo in a single patient, 14 lumineers 180 days after cementation. It was possible to observe images in various kinds of changes in the cementing line and the laminate. It was concluded that the OCT is an effective and promising method to clinical evaluation of the cementing line in lumineers.

  4. Optical Coherence Tomography Angiography in Fovea Plana.

    Science.gov (United States)

    Dolz-Marco, Rosa; Phasukkijwatana, Nopasak; Sarraf, David; Freund, K Bailey

    2016-07-01

    Fovea plana is characterized by the anatomical absence of the foveal pit in eyes with normal visual function. The authors have analyzed three cases of idiopathic fovea plana with optical coherence tomography angiography (OCTA). As previously reported, the authors found the absence of a foveal avascular zone in all cases with OCTA; however, a preserved fusion of both the superficial and the deep capillary plexuses was found around the foveal center. This novel observation cannot be detected with conventional dye-based angiography, in which the deep capillary plexus is not visualized. [Ophthalmic Surg Lasers Imaging Retina. 2016;47:670-673.].

  5. Visualization of two-photon Rabi oscillations in evanescently coupled optical waveguides

    Energy Technology Data Exchange (ETDEWEB)

    Ornigotti, M; Valle, G Della; Fernandez, T Toney; Laporta, P; Longhi, S [Dipartimento di Fisica and Istituto di Fotonica e Nanotecnologie del CNR, Politecnico di Milano, Piazza L. da Vinci 32, I-20133 Milano (Italy); Coppa, A; Foglietti, V [Istituto di Fotonica e Nanotecnologie del CNR, sezione di Roma, Via Cineto Romano 42, 00156 Roma (Italy)], E-mail: longhi@fisi.polimi.it

    2008-04-28

    An optical analogue of two-photon Rabi oscillations, occurring in a three-level atomic or molecular system coherently driven by two detuned laser fields, is theoretically proposed and experimentally demonstrated using three evanescently coupled optical waveguides realized on an active glass substrate. The optical analogue stems from the formal analogy between spatial propagation of light waves in the three-waveguide structure and the coherent temporal evolution of populations in a three-level atomic medium driven by two laser fields under two-photon resonance. In our optical experiment, two-photon Rabi oscillations are thus visualized as a slow spatial oscillatory exchange of light power between the two outer waveguides of the structure with a small excitation of the central waveguide.

  6. Digital processing optical transmission and coherent receiving techniques

    CERN Document Server

    Binh, Le Nguyen

    2013-01-01

    With coherent mixing in the optical domain and processing in the digital domain, advanced receiving techniques employing ultra-high speed sampling rates have progressed tremendously over the last few years. These advances have brought coherent reception systems for lightwave-carried information to the next stage, resulting in ultra-high capacity global internetworking. Digital Processing: Optical Transmission and Coherent Receiving Techniques describes modern coherent receiving techniques for optical transmission and aspects of modern digital optical communications in the most basic lines. The

  7. Snapshot Spectral Domain Optical Coherence Tomography

    Science.gov (United States)

    Valdez, Ashley

    Optical coherence tomography systems are used to image the retina in 3D to allow ophthalmologists diagnose ocular disease. These systems yield large data sets that are often labor-intensive to analyze and require significant expertise in order to draw conclusions, especially when used over time to monitor disease progression. Spectral Domain Optical Coherence Tomography (SD-OCT) instantly acquires depth profiles at a single location with a broadband source. These systems require mechanical scanning to generate two- or three-dimensional images. Instead of mechanically scanning, a beamlet array was used to permit multiple depth measurements on the retina with a single snapshot using a 3x 3 beamlet array. This multi-channel system was designed, assembled, and tested using a 1 x 2 beamlet lens array instead of a 3 x 3 beamlet array as a proof of concept prototype. The source was a superluminescent diode centered at 840nm with a 45nm bandwidth. Theoretical axial resolution was 6.92um and depth of focus was 3.45mm. Glass samples of varying thickness ranging from 0.18mm to 1.14mm were measured with the system to validate that correct depth profiles can be acquired for each channel. The results demonstrated the prototype system performed as expected, and is ready to be modified for in vivo applicability.

  8. Evaluation of microfluidic channels with optical coherence tomography

    KAUST Repository

    Czajkowski, J.

    2010-06-25

    Application of time domain, ultra high resolution optical coherence tomography (UHR-OCT) in evaluation of microfluidic channels is demonstrated. Presented study was done using experimental UHR-OCT device based on a Kerr-lens mode locked Ti:sapphire femtosecond laser, a photonic crystal fibre and modified, free-space Michelson interferometer. To show potential of the technique, microfluidic chip fabricated by VTT Center for Printed Intelligence (Oulu, Finland) was measured. Ability for full volumetric reconstruction in non-contact manner enabled complete characterization of closed entity of a microfluidic channel without contamination and harm for the sample. Measurement, occurring problems, and methods of postprocessing for raw data are described. Results present completely resolved physical structure of the channel, its spatial dimensions, draft angles and evaluation of lamination quality.

  9. Spatial coherence of thermal photons favors photosynthetic life

    CERN Document Server

    Manrique, Pedro; Caycedo-Soler, Felipe; Rodríguez, Ferney; Quiroga, Luis; Johnson, Neil

    2015-01-01

    Harvesting of sunlight underpins Life on Earth as well as driving novel energy device design. Though several experiments suggest that excitation energy transport and charge separation within a photosynthetic membrane may benefit from the quantum nature of their dynamics, the effects of spatial coherences in the incident light have been largely ignored. Here we show that spatial correlations in the incident light likely play an important role in trapping light and adding robustness, as well as providing a driving mechanism for an organism's adaptation toward more ordered structures. Our theory is grounded by empirical inputs, while its output is validated against testable predictions. Our results suggest that spatiotemporal correlations between photons, a fundamental property of the quantum world, should play a key role in our understanding of early Life and in improving the design of artificial photosynthetic systems.

  10. Coherent thermal conductance of 1-D photonic crystals

    Energy Technology Data Exchange (ETDEWEB)

    Tschikin, Maria [Institut für Physik, Carl von Ossietzky Universität, D-26111 Oldenburg (Germany); Ben-Abdallah, Philippe [Laboratoire Charles Fabry, UMR 8501, Institut d' Optique, CNRS, Université Paris-Sud, 2, Avenue Augustin Fresnel, RD128, 91127 Palaiseau Cedex (France); Biehs, Svend-Age, E-mail: biehs@theorie.physik.uni-oldenburg.de [Institut für Physik, Carl von Ossietzky Universität, D-26111 Oldenburg (Germany)

    2012-10-01

    We present an exact calculation of coherent thermal conductance in 1-D multilayer photonic crystals using the S-matrix method. In particular, we study the thermal conductance in a bilayer structure of Si/vacuum or Al{sub 2}O{sub 3}/vacuum slabs by means of the exact radiative heat flux expression. Based on the results obtained for the Al{sub 2}O{sub 3}/vacuum structure we show by comparison with previous works that the material losses and (localized) surface modes supported by the inner layers play a fundamental role and cannot be omitted in the definition of thermal conductance. Our results could have significant implications in the conception of efficient thermal barriers.

  11. Fiber optic based optical coherence tomography (OCT) for dental applications

    Energy Technology Data Exchange (ETDEWEB)

    Everett, M. J., LLNL

    1998-06-02

    We have developed a hand-held fiber optic based optical coherence tomography (OCT) system for scanning of the oral cavity We have produced, using this scanning device, in viva cross-sectional images of hard and soft dental tissues in human volunteers Clinically relevant anatomical structures, including the gingival margin, periodontal sulcus, and dento-enamel junction, were visible in all the images The dento-enamel junction and the alveolar bone were identifiable in approximately two thirds of the images These images represent, to our knowledge, the first in viva OCT images of human dental tissue.

  12. Adaptive optics optical coherence tomography for retina imaging

    Institute of Scientific and Technical Information of China (English)

    Guohua Shi; Yun Dai; Ling Wang; Zhihua Ding; Xuejun Rao; Yudong Zhang

    2008-01-01

    When optical coherence tomography (OCT) is used for human retina imaging, its transverse resolution is limited by the aberrations of human eyes. To overcome this disadvantage, a high resolution imaging system for living human retina, which consists of a time domain OCT system and a 37-elements adaptive optics (AO) system, has been developed. The AO closed loop rate is 20 frames per second, and the OCT has a 6.7-μm axial resolution. In this paper, this system is introduced and the high resolution imaging results for retina are presented.

  13. Universal discrete Fourier optics RF photonic integrated circuit architecture.

    Science.gov (United States)

    Hall, Trevor J; Hasan, Mehedi

    2016-04-04

    This paper describes a coherent electro-optic circuit architecture that generates a frequency comb consisting of N spatially separated orders using a generalised Mach-Zenhder interferometer (MZI) with its N × 1 combiner replaced by an optical N × N Discrete Fourier Transform (DFT). Advantage may be taken of the tight optical path-length control, component and circuit symmetries and emerging trimming algorithms offered by photonic integration in any platform that offers linear electro-optic phase modulation such as LiNbO3, silicon, III-V or hybrid technology. The circuit architecture subsumes all MZI-based RF photonic circuit architectures in the prior art given an appropriate choice of output port(s) and dimension N although the principal application envisaged is phase correlated subcarrier generation for all optical orthogonal frequency division multiplexing. A transfer matrix approach is used to model the operation of the architecture. The predictions of the model are validated by simulations performed using an industry standard software tool. Implementation is found to be practical.

  14. Ex vivo imaging of human thyroid pathology using integrated optical coherence tomography and optical coherence microscopy

    Science.gov (United States)

    Zhou, Chao; Wang, Yihong; Aguirre, Aaron D.; Tsai, Tsung-Han; Cohen, David W.; Connolly, James L.; Fujimoto, James G.

    2010-01-01

    We evaluate the feasibility of optical coherence tomography (OCT) and optical coherence microscopy (OCM) for imaging of benign and malignant thyroid lesions ex vivo using intrinsic optical contrast. 34 thyroid gland specimens are imaged from 17 patients, covering a spectrum of pathology ranging from normal thyroid to benign disease/neoplasms (multinodular colloid goiter, Hashimoto's thyroiditis, and follicular adenoma) and malignant thyroid tumors (papillary carcinoma and medullary carcinoma). Imaging is performed using an integrated OCT and OCM system, with sections. Characteristic features that suggest malignant lesions, such as complex papillary architecture, microfollicules, psammomatous calcifications, or replacement of normal follicular architecture with sheets/nests of tumor cells, can be identified from OCT and OCM images and are clearly differentiable from normal or benign thyroid tissues. With further development of needle-based imaging probes, OCT and OCM could be promising techniques to use for the screening of thyroid nodules and to improve the diagnostic specificity of fine needle aspiration evaluation.

  15. Erbium doped tellurite photonic crystal optical fiber

    Science.gov (United States)

    Osorio, Sergio P.; Fernandez, Enver; Rodriguez, Eugenio; Cesar, Carlos L.; Barbosa, Luiz C.

    2005-04-01

    In this work we present the fabrication of tellurite glass photonic crystal fiber doped with a very large erbium concentration. Tellurite glasses are important hosts for rare earth ions due to its very high solubility, which allows up to 10,000 ppm Er3+ concentrations. The photonic crystal optical fibers and tellurite glasses can be, therefore, combined in an efficient way to produce doped fibers for large bandwidth optical amplifiers. The preform was made of a 10 mm external diameter tellurite tube filled with an array of non-periodic tellurite capillaries and an erbium-doped telluride rod that constitute the fiber core. The preform was drawn in a Heathway Drawing Tower, producing fibers with diameters between 120 - 140 μm. We show optical microscope photography of the fiber"s transverse section. The ASE spectra obtained with a spectra analyzer show a red shift as the length of the optical fiber increases.

  16. Optical Coherence Tomography in a Needle Format

    Science.gov (United States)

    Lorenser, Dirk; McLaughlin, Robert A.; Sampson, David D.

    In this chapter, we review the technology and applications of needle probes for optical coherence tomography (OCT). Needle probes are miniaturized fiber-optic probes that can be mounted inside hypodermic needles, allowing them to be inserted deep into the body during OCT imaging. This overcomes the very limited imaging depth of OCT of only 2-3 mm in biological tissue, enabling access to deep-tissue locations that are beyond the reach of free-space optical scan heads or catheters. This chapter provides an in-depth review of the current state-of-the art in needle probe technology, including optical design and fabrication, scan mechanisms (including three-dimensional scanning), and integration into OCT systems. It also provides an overview of emerging applications of this fascinating new imaging tool in areas such as cancer diagnosis, pulmonary imaging, imaging of the eye and imaging of the brain. Finally, two case studies are presented, illustrating needle-based OCT imaging in breast cancer and lungs.

  17. Optical coherence tomography technology and applications

    CERN Document Server

    Fujimoto, James

    2015-01-01

    Optical coherence tomography (OCT) is the optical analog of ultrasound imaging and is a powerful imaging technique that enables non-invasive, in vivo, high resolution, cross-sectional imaging in biological tissue.  Between 30 to 40 Million OCT imaging procedures are performed per year in ophthalmology.  The overall market is estimated at more than 0.5 Billion USD.  A new generation OCT technology was developed, dramatically increasing resolution and speed, achieving in vivo optical biopsy, i.e. the visualization of tissue architectural morphology in situ and in real time.  Functional extensions of OCT technology enable non-invasive, depth resolved functional assessment and imaging of tissue.  The book introduces OCT technology and applications not only from an optical and technological viewpoint, but also from the biomedical and clinical perspective. This second edition is widely extended and covers significantly more topics then the first edition of this book. The chapters are written leading intern...

  18. All-Optical Formation of Coherent Dark States of Silicon-Vacancy Spins in Diamond

    Science.gov (United States)

    Pingault, Benjamin; Becker, Jonas N.; Schulte, Carsten H. H.; Arend, Carsten; Hepp, Christian; Godde, Tillmann; Tartakovskii, Alexander I.; Markham, Matthew; Becher, Christoph; Atatüre, Mete

    2014-12-01

    Spin impurities in diamond can be versatile tools for a wide range of solid-state-based quantum technologies, but finding spin impurities that offer sufficient quality in both photonic and spin properties remains a challenge for this pursuit. The silicon-vacancy center has recently attracted much interest because of its spin-accessible optical transitions and the quality of its optical spectrum. Complementing these properties, spin coherence is essential for the suitability of this center as a spin-photon quantum interface. Here, we report all-optical generation of coherent superpositions of spin states in the ground state of a negatively charged silicon-vacancy center using coherent population trapping. Our measurements reveal a characteristic spin coherence time, T2* , exceeding 45 nanoseconds at 4 K. We further investigate the role of phonon-mediated coupling between orbital states as a source of irreversible decoherence. Our results indicate the feasibility of all-optical coherent control of silicon-vacancy spins using ultrafast laser pulses.

  19. Secured Optical Communications Using Quantum Entangled Two-Photon Transparency Modulation

    Science.gov (United States)

    Kojima, Jun (Inventor); Nguyen, Quang-Viet (Inventor); Lekki, John (Inventor)

    2015-01-01

    A system and method is disclosed wherein optical signals are coded in a transmitter by tuning or modulating the interbeam delay time (which modulates the fourth-order coherence) between pairs of entangled photons. The photon pairs are either absorbed or not absorbed (transparent) by an atomic or molecular fluorescer in a receiver, depending on the inter-beam delay that is introduced in the entangled photon pairs. Upon the absorption, corresponding fluorescent optical emissions follow at a certain wavelength, which are then detected by a photon detector. The advantage of the disclosed system is that it eliminates a need of a coincidence counter to realize the entanglement-based secure optical communications because the absorber acts as a coincidence counter for entangled photon pairs.

  20. Evaluation of a cheap ultrasonic stage for light source coherence function measurement, optical coherence tomography and dynamic focusing

    NARCIS (Netherlands)

    Krstajic, Nikola; Matcher, Stephen J.; Childs, David; Steenbergen, Wiendelt; Hogg, Richard; Smallwood, Rod

    2009-01-01

    We evaluate the performance of a cheap ultrasonic stage in setups related to optical coherence tomography. The stage was used in several configurations: (1) optical delay line in an optical coherence tomography (OCT) setup; (2) as a delay line measuring coherence function of a low coherence source (

  1. Experimental Study on Coherence Time of a Light Field with Single Photon Counting

    Institute of Scientific and Technical Information of China (English)

    LI Yuan; ZHANG Yu-Chi; ZHANG Peng-Fei; GUO Yan-Qiang; LI Gang; WANG Jun-Min; ZHANG Tian-Cai

    2009-01-01

    The second-order degree of coherence of pseudo-thermal light and coherence time are experimentally studied via the Hanbruy-Brown-Twiss (HBT) scheme. The system consists of two non-photon-number-resolving single-photon-counting modules (SPCMs) operating in the Geiger mode. We investigate the coherence time of the incident beam for different spot sizes on a ground glass and speeds of a rotating ground glass. The corresponding coherence time can be obtained from Gaussian fitting for the measured second-order degree of coherence. The results show that the coherence time of measured pseudo-thermal fight depends on the spot sizes and the rotating speeds of the ground glass. The maximum value of the second-order degree of coherence is reduced as the rotating speed decreases. This result can be well explained by the model of mixed thermal and coherent fields with different ratios.

  2. In vivo cellular visualization of the human retina using optical coherence tomography and adaptive optics

    Energy Technology Data Exchange (ETDEWEB)

    Olivier, S S; Jones, S M; Chen, D C; Zawadzki, R J; Choi, S S; Laut, S P; Werner, J S

    2006-01-05

    Optical coherence tomography (OCT) sees the human retina sharply with adaptive optics. In vivo cellular visualization of the human retina at micrometer-scale resolution is possible by enhancing Fourier-domain optical-coherence tomography with adaptive optics, which compensate for the eye's optical aberrations.

  3. Digital Photonic Receivers for Wireless and Wireline Optical Fiber Transmission Links

    DEFF Research Database (Denmark)

    Guerrero Gonzalez, Neil

    investigations on the performance of data-aided optical channel estimation based on constant-amplitude zero-autocorrelation (CAZAC) sequences for 112 Gb/s polarization-diversity coherent optical fiber transmission links. The benefits of introducing digital signal processing functions in optically envelope......This PhD thesis addresses the design and performance evaluation of digital photonic receivers in hybrid optical fiber-wireless transmission systems. The research results presented in this thesis are pioneering in two areas. First, it is shown the first experimental demonstration of automatic...... demodulation of signals with mixed modulation formats and bit rates in a single digital coherent photonic receiver. The demodulated signals were generated on baseband and optical phase-modulated (PM) radio-over-fiber (RoF) systems. Secondly, it is presented the first known analytical and numerical...

  4. Angle-resolved optical coherence tomography

    Science.gov (United States)

    Desjardins, Adrien Emmanuel

    Optical coherence tomography (OCT) has emerged as a powerful tool for probing the microstructure of biological tissue non-invasively at high-speed. OCT measures depth-resolved reflectance of infrared light, generating cross-sectional images non-invasively with micron-scale resolution. As with other imaging modalities that employ coherent detection, OCT images are confounded by speckle noise. Speckle imposes a grainy texture on images that reduces the signal-to-noise ratio to near unity values. As a result, it conceals subtle differences in scattering properties known to be crucial for differentiating normal from diseased tissue states. In this thesis, we developed a novel OCT modality called "Angle-Resolved OCT" in which depth scans (A-lines) are obtained simultaneously from a broad range of backscattering angles. We demonstrated that high levels of speckle reduction can be achieved by averaging the magnitudes of A-lines corresponding to the same transverse locations. With both experimental and analytic approaches, we demonstrated that this averaging method does not lead to a substantial loss in spatial resolution. We developed two different imaging systems for performing Angle-Resolved OCT. With the first system, angular data was acquired simultaneously; with the second, it was acquired sequentially. The first system had superior speckle-reduction capabilities but image quality degraded significantly with small sample movements. The second system allowed for in vivo imaging, as demonstrated with Resolved OCT systems, the speckle-reduced images showed hitherto unprecedented delineation of tissue microstructure.

  5. Quantitative contrast-enhanced optical coherence tomography

    Energy Technology Data Exchange (ETDEWEB)

    Winetraub, Yonatan; SoRelle, Elliott D. [Molecular Imaging Program at Stanford, Stanford University, 299 Campus Drive, Stanford, California 94305 (United States); Bio-X Program, Stanford University, 299 Campus Drive, Stanford, California 94305 (United States); Biophysics Program, Stanford University, 299 Campus Drive, Stanford, California 94305 (United States); Department of Structural Biology, Stanford University, 299 Campus Drive, Stanford, California 94305 (United States); Liba, Orly [Molecular Imaging Program at Stanford, Stanford University, 299 Campus Drive, Stanford, California 94305 (United States); Bio-X Program, Stanford University, 299 Campus Drive, Stanford, California 94305 (United States); Department of Structural Biology, Stanford University, 299 Campus Drive, Stanford, California 94305 (United States); Department of Electrical Engineering, Stanford University, 299 Campus Drive, Stanford, California 94305 (United States); Zerda, Adam de la [Molecular Imaging Program at Stanford, Stanford University, 299 Campus Drive, Stanford, California 94305 (United States); Bio-X Program, Stanford University, 299 Campus Drive, Stanford, California 94305 (United States); Biophysics Program, Stanford University, 299 Campus Drive, Stanford, California 94305 (United States); Department of Structural Biology, Stanford University, 299 Campus Drive, Stanford, California 94305 (United States); Department of Electrical Engineering, Stanford University, 299 Campus Drive, Stanford, California 94305 (United States)

    2016-01-11

    We have developed a model to accurately quantify the signals produced by exogenous scattering agents used for contrast-enhanced Optical Coherence Tomography (OCT). This model predicts distinct concentration-dependent signal trends that arise from the underlying physics of OCT detection. Accordingly, we show that real scattering particles can be described as simplified ideal scatterers with modified scattering intensity and concentration. The relation between OCT signal and particle concentration is approximately linear at concentrations lower than 0.8 particle per imaging voxel. However, at higher concentrations, interference effects cause signal to increase with a square root dependence on the number of particles within a voxel. Finally, high particle concentrations cause enough light attenuation to saturate the detected signal. Predictions were validated by comparison with measured OCT signals from gold nanorods (GNRs) prepared in water at concentrations ranging over five orders of magnitude (50 fM to 5 nM). In addition, we validated that our model accurately predicts the signal responses of GNRs in highly heterogeneous scattering environments including whole blood and living animals. By enabling particle quantification, this work provides a valuable tool for current and future contrast-enhanced in vivo OCT studies. More generally, the model described herein may inform the interpretation of detected signals in modalities that rely on coherence-based detection or are susceptible to interference effects.

  6. Pure down-conversion photons through sub-coherence-length domain engineering

    Science.gov (United States)

    Graffitti, Francesco; Kundys, Dmytro; Reid, Derryck T.; Brańczyk, Agata M.; Fedrizzi, Alessandro

    2017-09-01

    Photonic quantum technology relies on efficient sources of coherent single photons, the ideal carriers of quantum information. Heralded single photons from parametric down-conversion can approximate on-demand single photons to a desired degree, with high spectral purities achieved through group-velocity matching and tailored crystal nonlinearities. Here we propose crystal-nonlinearity-engineering techniques with sub-coherence-length domains. We first introduce a combination of two existing methods: a deterministic approach with coherence-length domains and probabilistic domain-width annealing. We then show how the same deterministic domain-flip approach can be implemented with sub-coherence-length domains. Both of these complementary techniques create highly pure photons, outperforming previous methods, in particular for short nonlinear crystals matched to femtosecond lasers.

  7. Optical coherence tomography for diagnosing periodontal disease

    Science.gov (United States)

    Colston, Bill W., Jr.; Everett, Matthew J.; Da Silva, Luiz B.; Otis, Linda L.; Nathel, Howard

    1997-05-01

    We have, in this preliminary study, investigated the use of optical coherence tomography for diagnosis of periodontal disease. We took in vitro OCT images of the dental and periodontal tissues from a young pig and compared them to histological sections. These images distinguish tooth and soft tissue relationships that are important in diagnosing and assessing periodontal disease. We have imaged the attachment of gingiva to the tooth surface and located the cemento-enamel junction. This junction is an important reference point for defining attachment level in the diagnosis of periodontal disease. the boundary between enamel and dentin is also visible for most of the length of the anatomical crown, allowing quantitation of enamel thickness and character.

  8. The Choroid and Optical Coherence Tomography

    Directory of Open Access Journals (Sweden)

    Taha Sezer

    2016-01-01

    Full Text Available The choroid is the most vascular tissue in the eye and it plays an important role in the pathophysiology of various common chorioretinal diseases such as central serous retinopathy, age-related macular degeneration and degenerative myopia. Quantitative assessment of the choroid has been quite challenging with traditional imaging modalities such as indocyanine green angiography and ultrasonography due to limited resolution and repeatability. With the advent of optical coherence tomography (OCT technology, detailed visualization of the choroid in vivo is now possible. Measurements of choroidal thickness have also enabled new directions in research to study normal and pathological processes within the choroid. The aim of the present study is to review the current literature on choroidal imaging using OCT

  9. The Choroid and Optical Coherence Tomography

    Science.gov (United States)

    Sezer, Taha; Altınışık, Muhammet; Koytak, İbrahim Arif; Özdemir, Mehmet Hakan

    2016-01-01

    The choroid is the most vascular tissue in the eye and it plays an important role in the pathophysiology of various common chorioretinal diseases such as central serous retinopathy, age-related macular degeneration and degenerative myopia. Quantitative assessment of the choroid has been quite challenging with traditional imaging modalities such as indocyanine green angiography and ultrasonography due to limited resolution and repeatability. With the advent of optical coherence tomography (OCT) technology, detailed visualization of the choroid in vivo is now possible. Measurements of choroidal thickness have also enabled new directions in research to study normal and pathological processes within the choroid. The aim of the present study is to review the current literature on choroidal imaging using OCT. PMID:27800255

  10. Advanced modelling of optical coherence tomography systems

    DEFF Research Database (Denmark)

    Andersen, Peter E.; Thrane, L.; Yura, H.T.;

    2004-01-01

    Analytical and numerical models for describing and understanding the light propagation in samples imaged by optical coherence tomography (OCT) systems are presented. An analytical model for calculating the OCT signal based on the extended Huygens–Fresnel principle valid both for the single...... and multiple scattering regimes is reviewed. An advanced Monte Carlo model for calculating the OCT signal is also reviewed, and the validity of this model is shown through a mathematical proof based on the extended Huygens–Fresnel principle. Moreover, for the first time the model is verified experimentally....... From the analytical model, an algorithm for enhancing OCT images is developed; the so-called true-reflection algorithm in which the OCT signal may be corrected for the attenuation caused by scattering. For the first time, the algorithm is demonstrated by using the Monte Carlo model as a numerical...

  11. Image Distortion of Optical Coherence Tomography

    Institute of Scientific and Technical Information of China (English)

    安源; 姚建铨

    2004-01-01

    A kind of image distortion in Optical Coherence Tomography (OCT) resulted from average refractive index changes between structures of bio-tissue is discussed for the first time.Analysis is given on following situations:1) Exact refraction index changes between microstructures;2)The gradient of average refractive index change between different tissue layers is parallel to the probe beam;3) The gradient of average refractive index change is vertical to the probe beam.The results show that the image distortion of situation 1) is usually negligible;in situation 2) there is a spread or shrink effect without relative location error; however,in situation 3) there is a significant image error inducing relative location displacement between different structures.Preliminary design to eliminate the distortion is presented,the method of which mainly based on the image classification and pixel array re-arrangement.

  12. Generating multi-mode entangled coherent W and GHZ states via optical system based fusion mechanism

    Science.gov (United States)

    Zang, Xue-Ping; Yang, Ming; Wu, Wei-Feng; Fan, Hong-Yi

    2017-05-01

    Fusion technology has been demonstrated to be a good method for generating a large-scale entangled coherent W or GHZ state from two small ones in QED system. It is of importance to study how to fuse small-scale entangled coherent W or GHZ states via optical system. In this paper, we present a scheme for generating larger entangled coherent W or GHZ state in an optical system by virtue of fusion technology. The key fusion mechanism is realized by photon detectors and a Mach-Zehnder interferometer with its two arms immersed in Kerr media, by which an n-mode entangled coherent W state and an m-mode entangled coherent W state can be probabilistically fused into an (n+m-2)-mode entangled coherent W state. This fusion scheme applies to entangled coherent GHZ state too but with a unit probability of success. Feasibility analysis indicates that our fusion scheme may be realized with current experimental technology. Large-scale entangled coherent W and GHZ states may find new applications in quantum communication.

  13. Coherent manipulation of a solid-state artificial atom with few photons.

    Science.gov (United States)

    Giesz, V; Somaschi, N; Hornecker, G; Grange, T; Reznychenko, B; De Santis, L; Demory, J; Gomez, C; Sagnes, I; Lemaître, A; Krebs, O; Lanzillotti-Kimura, N D; Lanco, L; Auffeves, A; Senellart, P

    2016-06-17

    In a quantum network based on atoms and photons, a single atom should control the photon state and, reciprocally, a single photon should allow the coherent manipulation of the atom. Both operations require controlling the atom environment and developing efficient atom-photon interfaces, for instance by coupling the natural or artificial atom to cavities. So far, much attention has been drown on manipulating the light field with atomic transitions, recently at the few-photon limit. Here we report on the reciprocal operation and demonstrate the coherent manipulation of an artificial atom by few photons. We study a quantum dot-cavity system with a record cooperativity of 13. Incident photons interact with the atom with probability 0.95, which radiates back in the cavity mode with probability 0.96. Inversion of the atomic transition is achieved for 3.8 photons on average, showing that our artificial atom performs as if fully isolated from the solid-state environment.

  14. Entanglement distribution schemes employing coherent photon-to-spin conversion in semiconductor quantum dot circuits

    Science.gov (United States)

    Gaudreau, Louis; Bogan, Alex; Korkusinski, Marek; Studenikin, Sergei; Austing, D. Guy; Sachrajda, Andrew S.

    2017-09-01

    Long distance entanglement distribution is an important problem for quantum information technologies to solve. Current optical schemes are known to have fundamental limitations. A coherent photon-to-spin interface built with quantum dots (QDs) in a direct bandgap semiconductor can provide a solution for efficient entanglement distribution. QD circuits offer integrated spin processing for full Bell state measurement (BSM) analysis and spin quantum memory. Crucially the photo-generated spins can be heralded by non-destructive charge detection techniques. We review current schemes to transfer a polarization-encoded state or a time-bin-encoded state of a photon to the state of a spin in a QD. The spin may be that of an electron or that of a hole. We describe adaptations of the original schemes to employ heavy holes which have a number of attractive properties including a g-factor that is tunable to zero for QDs in an appropriately oriented external magnetic field. We also introduce simple throughput scaling models to demonstrate the potential performance advantage of full BSM capability in a QD scheme, even when the quantum memory is imperfect, over optical schemes relying on linear optical elements and ensemble quantum memories.

  15. Optical Coherence Tomography: Modeling and Applications

    DEFF Research Database (Denmark)

    Thrane, Lars

    in previous theoretical models of OCT systems. It is demonstrated that the shower curtain effect is of utmost importance in the theoretical description of an OCT system. The analytical model, together with proper noise analysis of the OCT system, enables calculation of the SNR, where the optical properties...... geometry, i.e., reflection geometry, is developed. As in the new OCT model, multiple scattered photons has been taken into account together with multiple scattering effects. As an important result, a novel method of creating images based on measurements of the momentum width of the Wigner phase......An analytical model is presented that is able to describe the performance of OCT systems in both the single and multiple scattering regimes simultaneously. This model inherently includes the shower curtain effect, well-known for light propagation through the atmosphere. This effect has been omitted...

  16. Coherent Light induced in Optical Fiber by a Charged Particle

    Science.gov (United States)

    Artru, Xavier; Ray, Cédric

    2016-07-01

    Coherent light production in an optical fiber by a charged particle (named PIGL, for particle-induced guided, light) is reviewed. From the microscopic point of view, light is emitted by transient electric dipoles induced in the fiber medium by the Coulomb field of the particle. The phenomenon can also considered as the capture of virtual photons of the particle field by the fiber. Two types of captures are distinguished. Type-I takes place in a uniform part of the fiber; then the photon keeps its longitudinal momentum pz . Type-II takes place near an end or in a non-uniform part of the fiber; then pz is not conserved. Type-I PIGL is not affected by background lights external to the fiber. At grazing incidence it becomes nearly monochromatic. Its circular polarization depends on the angular momentum of the particle about the fiber and on the relative velocity between the particle and the guided wave. A general formula for the yield of Type-II radiation, based on the reciprocity theorem, is proposed. This radiation can be assisted by metallic objects stuck to the fiber, via plasmon excitation. A periodic structure leads to a guided Smith-Purcell radiation. Applications of PIGL in beam diagnostics are considered.

  17. Photonic encryption using all optical logic.

    Energy Technology Data Exchange (ETDEWEB)

    Blansett, Ethan L.; Schroeppel, Richard Crabtree; Tang, Jason D.; Robertson, Perry J.; Vawter, Gregory Allen; Tarman, Thomas David; Pierson, Lyndon George

    2003-12-01

    With the build-out of large transport networks utilizing optical technologies, more and more capacity is being made available. Innovations in Dense Wave Division Multiplexing (DWDM) and the elimination of optical-electrical-optical conversions have brought on advances in communication speeds as we move into 10 Gigabit Ethernet and above. Of course, there is a need to encrypt data on these optical links as the data traverses public and private network backbones. Unfortunately, as the communications infrastructure becomes increasingly optical, advances in encryption (done electronically) have failed to keep up. This project examines the use of optical logic for implementing encryption in the photonic domain to achieve the requisite encryption rates. In order to realize photonic encryption designs, technology developed for electrical logic circuits must be translated to the photonic regime. This paper examines two classes of all optical logic (SEED, gain competition) and how each discrete logic element can be interconnected and cascaded to form an optical circuit. Because there is no known software that can model these devices at a circuit level, the functionality of the SEED and gain competition devices in an optical circuit were modeled in PSpice. PSpice allows modeling of the macro characteristics of the devices in context of a logic element as opposed to device level computational modeling. By representing light intensity as voltage, 'black box' models are generated that accurately represent the intensity response and logic levels in both technologies. By modeling the behavior at the systems level, one can incorporate systems design tools and a simulation environment to aid in the overall functional design. Each black box model of the SEED or gain competition device takes certain parameters (reflectance, intensity, input response), and models the optical ripple and time delay characteristics. These 'black box' models are interconnected and

  18. Optical coherence tomography for endodontic imaging

    Science.gov (United States)

    van Soest, G.; Shemesh, H.; Wu, M.-K.; van der Sluis, L. W. M.; Wesselink, P. R.

    2008-02-01

    In root canal therapy, complications frequently arise as a result of root fracture or imperfect cleaning of fins and invaginations. To date, there is no imaging method for nondestructive in vivo evaluation of the condition of the root canal, during or after treatment. There is a clinical need for a technique to detect defects before they give rise to complications. In this study we evaluate the ability of optical coherence tomography (OCT) to image root canal walls, and its capacity to identify complicating factors in root canal treatment. While the potential of OCT to identify caries has been explored before, endodontic imaging has not been reported. We imaged extracted lower front teeth after endodontic preparation and correlated these images to histological sections. A 3D OCT pullback scan was made with an endoscopic rotating optical fiber probe inside the root canal. All oval canals, uncleaned fins, risk zones, and one perforation that were detected by histology were also imaged by OCT. As an example of an area where OCT has clinical potential, we present a study of vertical root fracture identification with OCT.

  19. Optical coherence tomography used for internal biometrics

    Science.gov (United States)

    Chang, Shoude; Sherif, Sherif; Mao, Youxin; Flueraru, Costel

    2007-06-01

    Traditional biometric technologies used for security and person identification essentially deal with fingerprints, hand geometry and face images. However, because all these technologies use external features of human body, they can be easily fooled and tampered with by distorting, modifying or counterfeiting these features. Nowadays, internal biometrics which detects the internal ID features of an object is becoming increasingly important. Being capable of exploring under-skin structure, optical coherence tomography (OCT) system can be used as a powerful tool for internal biometrics. We have applied fiber-optic and full-field OCT systems to detect the multiple-layer 2D images and 3D profile of the fingerprints, which eventually result in a higher discrimination than the traditional 2D recognition methods. More importantly, the OCT based fingerprint recognition has the ability to easily distinguish artificial fingerprint dummies by analyzing the extracted layered surfaces. Experiments show that our OCT systems successfully detected the dummy, which was made of plasticene and was used to bypass the commercially available fingerprint scanning system with a false accept rate (FAR) of 100%.

  20. Hybrid materials for optics and photonics.

    Science.gov (United States)

    Lebeau, Benedicte; Innocenzi, Plinio

    2011-02-01

    The interest in organic-inorganic hybrids as materials for optics and photonics started more than 25 years ago and since then has known a continuous and strong growth. The high versatility of sol-gel processing offers a wide range of possibilities to design tailor-made materials in terms of structure, texture, functionality, properties and shape modelling. From the first hybrid material with optical functional properties that has been obtained by incorporation of an organic dye in a silica matrix, the research in the field has quickly evolved towards more sophisticated systems, such as multifunctional and/or multicomponent materials, nanoscale and self-assembled hybrids and devices for integrated optics. In the present critical review, we have focused our attention on three main research areas: passive and active optical hybrid sol-gel materials, and integrated optics. This is far from exhaustive but enough to give an overview of the huge potential of these materials in photonics and optics (254 references).

  1. Optical technologies for extreme-ultraviolet and soft X-ray coherent sources

    CERN Document Server

    Poletto, Luca

    2015-01-01

    The book reviews the most recent achievements in optical technologies for XUV and X-ray coherent sources. Particular attention is given to free-electron-laser facilities, but also to other sources available at present, such as synchrotrons, high-order laser harmonics and X-ray lasers. The optical technologies relevant to each type of source are discussed. In addition, the main technologies used for photon handling and conditioning, namely multilayer mirrors, adaptive optics, crystals and gratings are explained. Experiments using coherent light received during the last decades a lot of attention for the X-ray regime. Strong efforts were taken for the realization of almost fully coherent sources, e.g. the free-electron lasers, both as independent sources in the femtosecond and attosecond regimes and as seeding sources for free-electron-lasers and X-ray gas lasers. In parallel to the development of sources, optical technologies for photon handling and conditioning of such coherent and intense X-ray beams advance...

  2. Digital coherent transceiver for optical communications: from design to implementation

    OpenAIRE

    Anzuola Valencia, Esdras

    2012-01-01

    Establishing the basis of optical coherent transmission and detection which exploit digital signal processing (DSP) to optimize the performance of optical communication systems. [ANGLÈS] In this project we analyze the theoretical models of optical coherent communication systems as well as the front-end arquitectures used to implement them. Key concepts as balanced photo detection and quantum limit are explained and studied. Complex modulation schemes maximize spectral efficiency and power ...

  3. Optical generation and control of quantum coherence in semiconductor nanostructures

    CERN Document Server

    Slavcheva, Gabriela

    2010-01-01

    The unprecedented control of coherence that can be exercised in quantum optics of atoms and molecules has stimulated increasing efforts in extending it to solid-state systems. One motivation to exploit the coherent phenomena comes from the emergence of the quantum information paradigm, however many more potential device applications ranging from novel lasers to spintronics are all bound up with issues in coherence. The book focuses on recent advances in the optical control of coherence in excitonic and polaritonic systems as model systems for the complex semiconductor dynamics towards the goal

  4. Optical coherent control in semiconductors: Fringe contrast and inhomogeneous broadening

    DEFF Research Database (Denmark)

    Østergaard, John Erland; Vadim, Lyssenko; Hvam, Jørn Märcher

    2001-01-01

    Optical coherent control experiments in semiconductors reveal how inhomogeneous broadening must be taken into account in contrast to previous coherent control experiments in atomic and molecular systems. With spectral resolution elf the coherent control signal, the optical phases involved...... is observed in the four-wave mixing spectra as a function of phase-delay representing coherent control in the spectral domain. The spectral phase change of this modulation provides a spectroscopic tool to analyze contributions of inhomogeneous broadening to electronic resonances in semiconductor structures....

  5. Collective, Coherent, and Ultrastrong Coupling of 2D Electrons with Terahertz Cavity Photons

    CERN Document Server

    Zhang, Qi; Li, Xinwei; Reno, John L; Pan, Wei; Watson, John D; Manfra, Michael J; Kono, Junichiro

    2016-01-01

    Nonperturbative coupling of light with condensed matter in an optical cavity is expected to reveal a host of coherent many-body phenomena and states. In addition, strong coherent light-matter interaction in a solid-state environment is of great interest to emerging quantum-based technologies. However, creating a system that combines a long electronic coherence time, a large dipole moment, and a high cavity quality ($Q$) factor has been a challenging goal. Here, we report collective ultrastrong light-matter coupling in an ultrahigh-mobility two-dimensional electron gas in a high-$Q$ terahertz photonic-crystal cavity in a quantizing magnetic field, demonstrating a cooperativity of $\\sim$360. The splitting of cyclotron resonance (CR) into the lower and upper polariton branches exhibited a $\\sqrt{n_\\mathrm{e}}$-dependence on the electron density ($n_\\mathrm{e}$), a hallmark of collective vacuum Rabi splitting. Furthermore, a small but definite blue shift was observed for the polariton frequencies due to the norma...

  6. Characterization and Analysis of Relative Intensity Noise in Broadband Optical Sources for Optical Coherence Tomography

    Science.gov (United States)

    Shin, Sunghwan; Sharma, Utkarsh; Tu, Haohua; Jung, Woonggyu; Boppart, Stephen A.

    2011-01-01

    Relative intensity noise (RIN) is one of the most significant factors limiting the sensitivity of an optical coherence tomography (OCT) system. The existing and prevalent theory being used for estimating RIN for various light sources in OCT is questionable, and cannot be applied uniformly for different types of sources. The origin of noise in various sources differs significantly, owing to the different physical nature of photon generation. In this study, we characterize and compare RIN of several OCT light sources including superluminescent diodes (SLDs), an erbium-doped fiber amplifier, multiplexed SLDs, and a continuous-wave laser. We also report a method for reduction of RIN by amplifying the SLD light output by using a gain-saturated semiconductor optical amplifier. PMID:22090794

  7. Deterministic quantum nonlinear optics with single atoms and virtual photons

    Science.gov (United States)

    Kockum, Anton Frisk; Miranowicz, Adam; Macrı, Vincenzo; Savasta, Salvatore; Nori, Franco

    2017-06-01

    We show how analogs of a large number of well-known nonlinear-optics phenomena can be realized with one or more two-level atoms coupled to one or more resonator modes. Through higher-order processes, where virtual photons are created and annihilated, an effective deterministic coupling between two states of such a system can be created. In this way, analogs of three-wave mixing, four-wave mixing, higher-harmonic and -subharmonic generation (i.e., up- and down-conversion), multiphoton absorption, parametric amplification, Raman and hyper-Raman scattering, the Kerr effect, and other nonlinear processes can be realized. In contrast to most conventional implementations of nonlinear optics, these analogs can reach unit efficiency, only use a minimal number of photons (they do not require any strong external drive), and do not require more than two atomic levels. The strength of the effective coupling in our proposed setups becomes weaker the more intermediate transition steps are needed. However, given the recent experimental progress in ultrastrong light-matter coupling and improvement of coherence times for engineered quantum systems, especially in the field of circuit quantum electrodynamics, we estimate that many of these nonlinear-optics analogs can be realized with currently available technology.

  8. Active learning in optics and photonics

    Science.gov (United States)

    Niemela, Joseph J.

    2016-09-01

    Active learning in optics and photonics (ALOP) is a program of the International Basic Sciences Program at UNESCO, in collaboration with the Abdus Salam International Centre for Theoretical Physics (ICTP) and supported by SPIE, which is designed to help teachers in the developing world attract and retain students in the physical sciences. Using optics and photonics, it naturally attracts the interest of students and can be implemented using relatively low cost technologies, so that it can be more easily reproduced locally. The active learning methodology is student-centered, meaning the teachers give up the role of lecturer in favor of guiding and facilitating a learning process in which students engage in hands-on activities and active peer-peer discussions, and is shown to effectively enhance basic conceptual understanding of physics.

  9. Ultrathin lensed fiber-optic probe for optical coherence tomography.

    Science.gov (United States)

    Qiu, Y; Wang, Y; Belfield, K D; Liu, X

    2016-06-01

    We investigated and validated a novel method to develop ultrathin lensed fiber-optic (LFO) probes for optical coherence tomography (OCT) imaging. We made the LFO probe by attaching a segment of no core fiber (NCF) to the distal end of a single mode fiber (SMF) and generating a curved surface at the tip of the NCF using the electric arc of a fusion splicer. The novel fabrication approach enabled us to control the length of the NCF and the radius of the fiber lens independently. By strategically choosing these two parameters, the LFO probe could achieve a broad range of working distance and depth of focus for different OCT applications. A probe with 125μm diameter and lateral resolution up to 10μm was demonstrated. The low-cost, disposable and robust LFO probe is expected to have great potential for interstitial OCT imaging.

  10. Transsynaptic retinal degeneration in optic neuropathies: optical coherence tomography study.

    Science.gov (United States)

    Sriram, Prema; Graham, Stuart L; Wang, Chenyu; Yiannikas, Con; Garrick, Raymond; Klistorner, Alexander

    2012-03-09

    Recently demonstrated neuronal loss in the inner nuclear layer of the retina in multiple sclerosis (MS) and glaucoma raises the question of a primary (possibly immune-mediated) or secondary (transsynaptic) mechanism of retinal damage in these diseases. In the present study we used optical coherence tomography to investigate retrograde retinal transsynaptic degeneration in patients with long-standing and severe loss of ganglion cells due to optic neuropathy. Fifteen eyes of glaucoma patients with visual field defect limited to upper hemifield and 15 eyes of MS patients with previous episode of optic neuritis (ON) and extensive loss of ganglion cells were imaged using spectral-domain optical coherence tomography and compared with two groups of age-matched controls. Combined retinal ganglion cell layer/inner plexiform layer (GCL/IPL) thickness and inner nuclear layer (INL) thickness were analyzed. In the glaucoma group there was a significant (P = 0.0005) reduction of GCL/IPL thickness in the lower (affected) retina compared with normal controls; however INL thickness was not statistically reduced (P = 0.49). In the MS group reduction of GCL/IPL thickness in both hemifields of ON eyes was also significant (P = 0.0001 and P < 0.0001 for inferior and superior retina respectively). However, similar to the glaucomatous eyes, there was no significant reduction of INL thickness in both hemifields (P = 0.25 and P = 0.45). This study demonstrates no significant loss of INL thickness in parts of the retina with long-standing and severe loss of retinal ganglion cells.

  11. Integrated optical coherence tomography and optical coherence microscopy imaging of human pathology

    Science.gov (United States)

    Lee, Hsiang-Chieh; Zhou, Chao; Wang, Yihong; Aquirre, Aaron D.; Tsai, Tsung-Han; Cohen, David W.; Connolly, James L.; Fujimoto, James G.

    2010-02-01

    Excisional biopsy is the current gold standard for disease diagnosis; however, it requires a relatively long processing time and it may also suffer from unacceptable false negative rates due to sampling errors. Optical coherence tomography (OCT) is a promising imaging technique that provide real-time, high resolution and three-dimensional (3D) images of tissue morphology. Optical coherence microscopy (OCM) is an extension of OCT, combining both the coherence gating and the confocal gating techniques. OCM imaging achieves cellular resolution with deeper imaging depth compared to confocal microscopy. An integrated OCT/OCM imaging system can provide co-registered multiscale imaging of tissue morphology. 3D-OCT provides architectural information with a large field of view and can be used to find regions of interest; while OCM provides high magnification to enable cellular imaging. The integrated OCT/OCM system has an axial resolution of kidney (19), were imaged with OCT and OCM within 2 to 6 hours after excision. The images were compared with H & E histology to identify characteristic features useful for disease diagnosis. The feasibility of visualizing human pathology using integrated OCT/OCM was demonstrated in the pathology laboratory settings.

  12. Multimodal full-field optical coherence tomography on biological tissue: toward all optical digital pathology

    Science.gov (United States)

    Harms, F.; Dalimier, E.; Vermeulen, P.; Fragola, A.; Boccara, A. C.

    2012-03-01

    Optical Coherence Tomography (OCT) is an efficient technique for in-depth optical biopsy of biological tissues, relying on interferometric selection of ballistic photons. Full-Field Optical Coherence Tomography (FF-OCT) is an alternative approach to Fourier-domain OCT (spectral or swept-source), allowing parallel acquisition of en-face optical sections. Using medium numerical aperture objective, it is possible to reach an isotropic resolution of about 1x1x1 ìm. After stitching a grid of acquired images, FF-OCT gives access to the architecture of the tissue, for both macroscopic and microscopic structures, in a non-invasive process, which makes the technique particularly suitable for applications in pathology. Here we report a multimodal approach to FF-OCT, combining two Full-Field techniques for collecting a backscattered endogeneous OCT image and a fluorescence exogeneous image in parallel. Considering pathological diagnosis of cancer, visualization of cell nuclei is of paramount importance. OCT images, even for the highest resolution, usually fail to identify individual nuclei due to the nature of the optical contrast used. We have built a multimodal optical microscope based on the combination of FF-OCT and Structured Illumination Microscopy (SIM). We used x30 immersion objectives, with a numerical aperture of 1.05, allowing for sub-micron transverse resolution. Fluorescent staining of nuclei was obtained using specific fluorescent dyes such as acridine orange. We present multimodal images of healthy and pathological skin tissue at various scales. This instrumental development paves the way for improvements of standard pathology procedures, as a faster, non sacrificial, operator independent digital optical method compared to frozen sections.

  13. Optical isolation via unidirectional resonant photon tunneling

    CERN Document Server

    Moccia, Massimo; Galdi, Vincenzo; Alu', Andrea; Engheta, Nader

    2013-01-01

    We show that tri-layer structures combining epsilon-negative and magneto-optical material layers can exhibit unidirectional resonant photon tunneling phenomena that can discriminate between circularly-polarized (CP) waves of given handedness impinging from opposite directions, or between CP waves with different handedness impinging from the same direction. This physical principle may be utilized to design compact optical isolators for CP waves. Within this framework, we derive simple analytical conditions and design formulae, and quantitatively assess the isolation performance, also taking into account the unavoidable imperfections and nonidealities.

  14. Photonic crystal surface waves for optical biosensors.

    Science.gov (United States)

    Konopsky, Valery N; Alieva, Elena V

    2007-06-15

    We present a new optical biosensor technique based on registration of dual optical s-polarized modes on a photonic crystal surface. The simultaneous registration of two optical surface waves with different evanescent depths from the same surface spot permits the segregation of the volume and the surface contributions from an analyte, while the absence of metal damping permits an increase in the propagation length of the optical surface waves and the sensitivity of the biosensor. Our technique was tested with the binding of biotin molecules to a streptavidin monolayer that has been detected with signal/noise ratio of approximately 15 at 1-s signal accumulation time. The detection limit is approximately 20 fg of the analyte on the probed spot of the surface.

  15. The current trends of optics and photonics

    CERN Document Server

    2015-01-01

    Optics and photonics offer new and vibrant approaches to meeting the challenges of the 21st century concerning energy conservation, education, agriculture, personal health and the environment. One of the most effective ways to address these global problems is to provide updated and reliable content on light-based technologies. Optical thin films and meta-materials, lasers, optical communications, light-emitting diodes, solar cells, liquid crystal technology, nanophotonics and biophotonics all play vital roles in enriching our lives. We hope to raise readers’ awareness of how optical technologies are now promoting sustainable development and providing reliable solutions to basic human needs. Furthermore, in order to broaden new research fields, we hope to inspire them to pursue further cutting-edge breakthroughs on the basis of the accomplishments that have already been made.

  16. Photonics technology development for optical fuzing

    Science.gov (United States)

    Geib, K. M.; Serkland, D. K.; Keeler, G. A.; Peake, G. M.; Mar, A.; von der Lippe, C. M.; Liu, J. J.

    2005-09-01

    This paper describes the photonic component development taking place at Sandia National Laboratories, ARDEC and the Army Research Laboratory in support of an effort to develop a robust, compact, and affordable photonic proximity sensor for munitions fuzing applications. Successful implementation of this sensor will provide a new capability for direct fire applications. The technologies under investigation for the optical fuze design covered in this paper are vertical-cavity surface-emitting lasers (VCSELs), vertical-external-cavity surface-emitting lasers (VECSELs), integrated resonant-cavity photodetectors (RCPDs), and refractive micro-optics. The culmination of this work will be low cost, robust, fully integrated, g-hardened components suitable for proximity fuzing applications. The use of advanced photonic components will enable replacement of costly assemblies that employ discrete lasers, photodetectors, and bulk optics. The integrated devices will be mass produced and impart huge savings for a variety of Army applications. The specific application under investigation is for gun-fired munitions. Nevertheless, numerous civilian uses exist for this proximity sensor in automotive, robotics and aerospace applications. This technology is also applicable to robotic ladar and short-range 3-D imaging.

  17. Coherent supercontinuum generation in a silicon photonic wire in the telecommunication wavelength range.

    Science.gov (United States)

    Leo, François; Gorza, Simon-Pierre; Coen, Stéphane; Kuyken, Bart; Roelkens, Gunther

    2015-01-01

    We demonstrate a fully coherent supercontinuum spectrum spanning 500 nm from a silicon-on-insulator photonic wire waveguide pumped at 1575 nm wavelength. An excellent agreement with numerical simulations is reported. The simulations also show that a high level of two-photon absorption can essentially enforce the coherence of the spectral broadening process irrespective of the pump pulse duration.

  18. ƒ(R Gravity, Relic Coherent Gravitons and Optical Chaos

    Directory of Open Access Journals (Sweden)

    Lawrence B. Crowell

    2014-03-01

    Full Text Available We discuss the production of massive relic coherent gravitons in a particular class of ƒ(R gravity, which arises from string theory, and their possible imprint in the Cosmic Microwave Background. In fact, in the very early Universe, these relic gravitons could have acted as slow gravity waves. They may have then acted to focus the geodesics of radiation and matter. Therefore, their imprint on the later evolution of the Universe could appear as filaments and a domain wall in the Universe today. In that case, the effect on the Cosmic Microwave Background should be analogous to the effect of water waves, which, in focusing light, create optical caustics, which are commonly seen on the bottom of swimming pools. We analyze this important issue by showing how relic massive gravity waves (GWs perturb the trajectories of the Cosmic Microwave Background photons (gravitational lensing by relic GWs. The consequence of the type of physics discussed is outlined by illustrating an amplification of what might be called optical chaos.

  19. Coherence properties of supercontinuum generated in highly nonlinear photonic crystal fibers

    Science.gov (United States)

    Zhang, Yuji

    In this dissertation, experimentally measured spectral and coherence evolution of supercontinuum (SC) is presented. Highly nonlinear soft-glass photonic crystal fibers (PCF) were used for SC generation, including lead-silicate (Schott SF6) PCFs of a few different lengths: 10.5 cm, 4.7 mm, and 3.9 mm, and a tellurite PCF of 2.7 cm. The pump is an optical parametric oscillator (OPO) at 1550 nm with pulse energy in the order of nanojoule (nJ) and pulse duration of 105 femtosecond (fs). The coherence of SC was measured using the delayed-pulse method, where the interferometric signal was sent into an optical spectrum analyzer (OSA) and spectral fringes were recorded. By tuning the pump power, power-dependent evolution of spectrum and coherence was obtained. Numerical simulations based on the generalized nonlinear Schrodinger equation (GNLSE) were performed. To match the measured data, the simulated spectral evolution was optimized by iteratively tuning parameters and comparing features. To further match the simulated coherence evolution with the measurement, shot noise and pulse-to-pulse power fluctuation were added in the pump, and the standard deviation of the fluctuation was tuned. Good agreement was obtained between the simulated and the measured spectral evolution, in spite of the unavailability of some physical parameters for simulation. It is demonstrated in principle that, given a measured spectral evolution, the fiber length, and the average power of SC, all other parameters can be determined unambiguously, and the spectral evolution can be reproduced in the simulations. Most importantly, the soliton fission length can be simulated accurately. The spectral evolution using the 4.7- and the 3.9-mm SF6 PCFs shows a pattern dominated by self phase modulation (SPM). This indicates that, these fiber lengths are close to the soliton fission length at the maximum power. The spectral evolution using the 10.5-cm SF6 PCF and the 2.7-cm tellurite PCF shows a soliton

  20. Partially coherent sources which produce the same far zone optical force as a laser beam

    CERN Document Server

    Auñon, Juan Miguel

    2013-01-01

    On applying a theorem previously derived by Wolf and Collett, we demonstrate that partially coherent Gaussian Schell model uctuating sources (GSMS) produce exactly the same optical forces as a fully coherent laser beam. We also show that this kind of sources helps to control the light-matter interaction in biological samples which are very sensitive to thermal heating induced by higher power intensities; and hence the invasiveness of the manipulation. This is a consequence of the fact that the same photonic force can be obtained with a low intensity GSMS as with a high intensity laser beam.

  1. Coherent perfect absorption in deeply subwavelength films in the single photon regime

    CERN Document Server

    Roger, Thomas; Bolduc, Eliot; Valente, Joao; Heitz, Julius J F; Jeffers, John; Soci, Cesare; Leach, Jonathan; Couteau, Christophe; Zheludev, Nikolay; Faccio, Daniele

    2016-01-01

    The technologies of heating, photovoltaics, water photocatalysis and artificial photosynthesis depend on the absorption of light and novel approaches such as coherent absorption from a standing wave promise total dissipation of energy. Extending the control of absorption down to very low light levels and eventually to the single photon regime is of great interest yet remains largely unexplored. Here we demonstrate the coherent absorption of single photons in a deeply sub-wavelength 50% absorber. We show that while absorption of photons from a travelling wave is probabilistic, standing wave absorption can be observed deterministically, with nearly unitary probability of coupling a photon into a mode of the material, e.g. a localised plasmon when this is a metamaterial excited at the plasmon resonance. These results bring a better understanding of the coherent absorption process, which is of central importance for light harvesting, detection, sensing and photonic data processing applications.

  2. Efficiency and Coherence of Quantum-Dot Single-Photon Sources

    DEFF Research Database (Denmark)

    Madsen, Marta Arcari

    The main goal of the project has been to realize an efficient source of coherent single photons by coupling a self-assembled quantum dot to a photonic crystal waveguide. Such a source would have a wide range of applications in the field of quantum information processing. By studying the coupling...... on this result, we improved the design of the photonic crystal waveguide, and we characterized in detail the efficiency of the device and the coherence of the emitted single photons. We investigate the decoherence mechanisms affecting the quantum dots by performing resonance fluorescence experiments on emitters...... of a single charge. A very high degree of coherence can be achieved by embedding quantum dots in electrically gated samples. We show that a single quantum dot behaves like a nearly-ideal two-level system in a sample with electrical gates, and single photons emitted up to 1 μs apart show indistinguishability...

  3. Evaluating the Use of Optical Coherence Tomography in Optic Neuritis

    Directory of Open Access Journals (Sweden)

    Fiona Costello

    2011-01-01

    Full Text Available Optic neuritis (ON is an inflammatory optic nerve injury, which is strongly associated with multiple sclerosis (MS. Axonal damage in the optic nerve manifests as retinal nerve fiber layer (RNFL deficits, which can be readily quantified with optical coherence tomography (OCT. The RNFL represents the most proximal region of the afferent visual pathway; and, as such, is a unique region of the central nervous system (CNS because it lacks myelin. Changes in retinal integrity can be correlated with reliable and quantifiable visual outcomes to provide a structural-functional paradigm of CNS injury. Because the eye provides a unique “view” into the effects of CNS inflammation, the ON “system model” may provide greater understanding about disease mechanisms, which underpin disability in MS. This review addresses the applications of OCT in study of ON patients, with specific reference to the published reports to date. The future role of OCT is discussed, both in terms of the potential gains and certain challenges associated with this evolving technology.

  4. Optical Biopsy Using Tissue Spectroscopy and Optical Coherence Tomography

    Directory of Open Access Journals (Sweden)

    Norman S Nishioka

    2003-01-01

    Full Text Available ‘Optical biopsy’ or ‘optical diagnostics’ is a technique whereby light energy is used to obtain information about the structure and function of tissues without disrupting them. In fluorescence spectroscopy, light energy (usually provided by a laser is used to excite tissues and the resulting fluorescence provides information about the target tissue. Its major gastrointestinal application has been in the evaluation of colonic polyps, in which it can reliably distinguish malignant from benign lesions. Optical coherence tomography (OCT has been used in the investigation of Barrett’s epithelium (and dysplasia, although a variety of other applications are feasible. For example, OCT could assist in the identification and staging of mucosal and submucosal neoplasms, the grading of inflammation in the stomach and intestine, the diagnosis of biliary tumours and the assessment of villous architecture. OCT differs from endoscopic ultrasound, a complementary modality, in that it has a much higher resolution but lesser depth of penetration. The images correlate with the histopathological appearance of tissues, and the addition of Doppler methods may enable it to evaluate the vascularity of tumours and the amount of blood flow in varices. Refinements in these new optical techniques will likely make them valuable in clinical practice, although their specific roles have yet to be determined.

  5. Special Polymer Optical Fibres and Devices for Photonic Applications

    Institute of Scientific and Technical Information of China (English)

    Gang-Ding Peng

    2003-01-01

    Remarkable progresses have been made in developing special polymer optical fibres and devices for photonic applications in recent years. This presentation will mainly report on the development of electro-optic, photosensitive and photorefractive polymer optical fibres and related devices.

  6. Experimental demonstration of coherent feedback control on optical field squeezing

    CERN Document Server

    Iida, Sanae; Yonezawa, Hidehiro; Yamamoto, Naoki; Furusawa, Akira

    2011-01-01

    Coherent feedback is a non-measurement based, hence a back-action free, method of control for quantum systems. A typical application of this control scheme is squeezing enhancement, a purely non-classical effect in quantum optics. In this paper we report its first experimental demonstration that well agrees with the theory taking into account time delays and losses in the coherent feedback loop. The results clarify both the benefit and the limitation of coherent feedback control in a practical situation.

  7. Motion contrast using optical coherence tomography

    Science.gov (United States)

    Fingler, Jeffrey Paul

    Diagnosis of ophthalmic diseases like age-related macular degeneration is very important for treatment of the disease as well as the development of future treatments. Optical coherence tomography (OCT) is an optical interference technique which can measure the three-dimensional structural information of the reflecting layers within a sample. In retinal imaging, OCT is used as the primary diagnostic tool for structural abnormalities such as retinal holes and detachments. The contrast within the images of this technique is based upon reflectivity changes from different regions of the retina. This thesis demonstrates the developments of methods used to produce additional contrast to the structural OCT images based on the tiny fluctuations of motion experienced by the mobile scatterers within a sample. Motion contrast was observed for motions smaller than 50 nm in images of a variety of samples. Initial contrast method demonstrations used Brownian motion differences to separate regions of a mobile Intralipid solution from a static agarose gel, chosen in concentration to minimize reflectivity contrast. Zebrafish embryos in the range of 3-4 days post fertilization were imaged using several motion contrast methods to determine the capabilities of identifying regions of vascular flow. Vasculature identification was demonstrated in zebrafish for blood vessels of all orientations as small as 10 microns in diameter. Mouse retinal imaging utilized the same motion contrast methods to determine the contrast capabilities for motions associated with vasculature within the retina. Improved contrast imaging techniques demonstrated comparable images to fluorescein angiography, the gold standard of retinal vascular imaging. Future studies can improve the demonstrated contrast analysis techniques and apply them towards human retinal motion contrast imaging for ophthalmic diagnostic purposes.

  8. Complete denture analyzed by optical coherence tomography

    Science.gov (United States)

    Negrutiu, Meda L.; Sinescu, Cosmin; Todea, Carmen; Podoleanu, Adrian G.

    2008-02-01

    The complete dentures are currently made using different technologies. In order to avoid deficiencies of the prostheses made using the classical technique, several alternative systems and procedures were imagined, directly related to the material used and also to the manufacturing technology. Thus, at the present time, there are several injecting systems and technologies on the market, that use chemoplastic materials, which are heat cured (90-100°C), in dry or wet environment, or cold cured (below 60°C). There are also technologies that plasticize a hard cured material by thermoplastic processing (without any chemical changes) and then inject it into a mold. The purpose of this study was to analyze the existence of possible defects in several dental prostheses using a non invasive method, before their insertion in the mouth. Different dental prostheses, fabricated from various materials were investigated using en-face optical coherence tomography. In order to discover the defects, the scanning was made in three planes, obtaining images at different depths, from 0,01 μm to 2 mm. In several of the investigated prostheses we found defects which may cause their fracture. These defects are totally included in the prostheses material and can not be vizualised with other imagistic methods. In conclusion, en-face OCT is an important investigative tool for the dental practice.

  9. Optical coherence tomography angiography in retinal diseases

    Directory of Open Access Journals (Sweden)

    K V Chalam

    2016-01-01

    Full Text Available Optical coherence tomography angiography (OCTA is a new, non-invasive imaging system that generates volumetric data of retinal and choroidal layers. It has the ability to show both structural and blood flow information. Split-spectrum amplitude-decorrelation angiography (SSADA algorithm (a vital component of OCTA software helps to decrease the signal to noise ratio of flow detection thus enhancing visualization of retinal vasculature using motion contrast. Published studies describe potential efficacy for OCTA in the evaluation of common ophthalmologic diseases such as diabetic retinopathy, age related macular degeneration (AMD, retinal vascular occlusions and sickle cell disease. OCTA provides a detailed view of the retinal vasculature, which allows accurate delineation of microvascular abnormalities in diabetic eyes and vascular occlusions. It helps quantify vascular compromise depending upon the severity of diabetic retinopathy. OCTA can also elucidate the presence of choroidal neovascularization (CNV in wet AMD. In this paper, we review the knowledge, available in English language publications regarding OCTA, and compare it with the conventional angiographic standard, fluorescein angiography (FA. Finally, we summarize its potential applications to retinal vascular diseases. Its current limitations include a relatively small field of view, inability to show leakage, and tendency for image artifacts. Further larger studies will define OCTA's utility in clinical settings and establish if the technology may offer a non-invasive option of visualizing the retinal vasculature, enabling us to decrease morbidity through early detection and intervention in retinal diseases.

  10. International Conference on Coherence and Quantum Optics

    CERN Document Server

    RECENT DEVELOPMENTS IN QUANTUM OPTICS

    1993-01-01

    This volume is composed of papers (invited and contributed) presented at the International Conference on Coherence and Quantum Optics held at the University of Hyderabad January 5-January 10, 1991. It has been organized by Professor Girish Agarwal and his colleagues at the School of Physics, University of Hyderabad, Hyder­ abad, India under partial support from the Department of Science and Technology, Government of India, International Center for Theoretical Physics, Trieste, Italy and the National Science Foundation, USA. Without the untiring efforts of Prof. Girish Agarwal and the members of his quantum office group, the Conference and the present volume would not have been possible. Some extraordinary circumstances resulted in a delay of the publication of the present volume. Our sincere apologies to all the authors. We deeply regret the inconvenience caused due to the delay. A debt of gratitude is due to Ms. Kim Bella for the excellent typing job of the different versions and the final version of the ma...

  11. Anatomic Optical Coherence Tomography of Upper Airways

    Science.gov (United States)

    Chin Loy, Anthony; Jing, Joseph; Zhang, Jun; Wang, Yong; Elghobashi, Said; Chen, Zhongping; Wong, Brian J. F.

    The upper airway is a complex and intricate system responsible for respiration, phonation, and deglutition. Obstruction of the upper airways afflicts an estimated 12-18 million Americans. Pharyngeal size and shape are important factors in the pathogenesis of airway obstructions. In addition, nocturnal loss in pharyngeal muscular tone combined with high pharyngeal resistance can lead to collapse of the airway and periodic partial or complete upper airway obstruction. Anatomical optical coherence tomography (OCT) has the potential to provide high-speed three-dimensional tomographic images of the airway lumen without the use of ionizing radiation. In this chapter we describe the methods behind endoscopic OCT imaging and processing to generate full three dimensional anatomical models of the human airway which can be used in conjunction with numerical simulation methods to assess areas of airway obstruction. Combining this structural information with flow dynamic simulations, we can better estimate the site and causes of airway obstruction and better select and design surgery for patients with obstructive sleep apnea.

  12. Ultrahigh-resolution endoscopic optical coherence tomography

    Science.gov (United States)

    Chen, Yu; Herz, Paul R.; Hsiung, Pei-Lin; Aguirre, Aaron D.; Mashimo, Hiroshi; Desai, Saleem; Pedrosa, Macos; Koski, Amanda; Schmitt, Joseph M.; Fujimoto, James G.

    2005-01-01

    Early detection of gastrointestinal cancer is essential for the patient treatment and medical care. Endoscopically guided biopsy is currently the gold standard for the diagnosis of early esophageal cancer, but can suffer from high false negative rates due to sampling errors. Optical coherence tomography (OCT) is an emerging medical imaging technology which can generate high resolution, cross-sectional images of tissue in situ and in real time, without the removal of tissue specimen. Although endoscopic OCT has been used successfully to identify certain pathologies in the gastrointestinal tract, the resolution of current endoscopic OCT systems has been limited to 10 - 15 m for clinical procedures. In this study, in vivo imaging of the gastrointestinal tract is demonstrated at a three-fold higher resolution (gastro-esophageal junction and colon on animal model display tissue microstructures and architectural details at high resolution, and the features observed in the OCT images are well-matched with histology. The clinical feasibility study is conducted through delivering OCT imaging catheter using standard endoscope. OCT images of normal esophagus, Barrett's esophagus, and esophageal cancers are demonstrated with distinct features. The ability of high resolution endoscopic OCT to image tissue morphology at an unprecedented resolution in vivo would facilitate the development of OCT as a potential imaging modality for early detection of neoplastic changes.

  13. Optical Coherence Tomography Angiography in Retinal Diseases.

    Science.gov (United States)

    Chalam, K V; Sambhav, Kumar

    2016-01-01

    Optical coherence tomography angiography (OCTA) is a new, non-invasive imaging system that generates volumetric data of retinal and choroidal layers. It has the ability to show both structural and blood flow information. Split-spectrum amplitude-decorrelation angiography (SSADA) algorithm (a vital component of OCTA software) helps to decrease the signal to noise ratio of flow detection thus enhancing visualization of retinal vasculature using motion contrast. Published studies describe potential efficacy for OCTA in the evaluation of common ophthalmologic diseases such as diabetic retinopathy, age related macular degeneration (AMD), retinal vascular occlusions and sickle cell disease. OCTA provides a detailed view of the retinal vasculature, which allows accurate delineation of microvascular abnormalities in diabetic eyes and vascular occlusions. It helps quantify vascular compromise depending upon the severity of diabetic retinopathy. OCTA can also elucidate the presence of choroidal neovascularization (CNV) in wet AMD. In this paper, we review the knowledge, available in English language publications regarding OCTA, and compare it with the conventional angiographic standard, fluorescein angiography (FA). Finally, we summarize its potential applications to retinal vascular diseases. Its current limitations include a relatively small field of view, inability to show leakage, and tendency for image artifacts. Further larger studies will define OCTA's utility in clinical settings and establish if the technology may offer a non-invasive option of visualizing the retinal vasculature, enabling us to decrease morbidity through early detection and intervention in retinal diseases.

  14. Anterior Eye Imaging with Optical Coherence Tomography

    Science.gov (United States)

    Huang, David; Li, Yan; Tang, Maolong

    The development of corneal and anterior segment optical coherence tomography (OCT) technology has advanced rapidly in recently years. The scan geometry and imaging wavelength are both important choices to make in designing anterior segment OCT systems. Rectangular scan geometry offers the least image distortion and is now used in most anterior OCT systems. The wavelength of OCT light source affects resolution and penetration. An optimal choice of the OCT imaging wavelength (840, 1,050, or 1,310 nm) depends on the application of interest. Newer generation Fourier-domain OCT technology can provide scan speed 100-1000 times faster than the time-domain technology. Various commercial anterior OCT systems are available on the market. A wide spectrum of diagnostic and surgical applications using anterior segment OCT had been investigated, including mapping of corneal and epithelial thicknesses, keratoconus screening, measuring corneal refractive power, corneal surgery planning and evaluation in LASIK, intracorneal ring implantation, assessment of angle closure glaucoma, anterior chamber biometry and intraocular lens implants, intraocular lens power calculation, and eye bank donor cornea screening.

  15. Photodynamic therapy monitoring with optical coherence angiography

    Science.gov (United States)

    Sirotkina, M. A.; Matveev, L. A.; Shirmanova, M. V.; Zaitsev, V. Y.; Buyanova, N. L.; Elagin, V. V.; Gelikonov, G. V.; Kuznetsov, S. S.; Kiseleva, E. B.; Moiseev, A. A.; Gamayunov, S. V.; Zagaynova, E. V.; Feldchtein, F. I.; Vitkin, A.; Gladkova, N. D.

    2017-01-01

    Photodynamic therapy (PDT) is a promising modern approach for cancer therapy with low normal tissue toxicity. This study was focused on a vascular-targeting Chlorine E6 mediated PDT. A new angiographic imaging approach known as M-mode-like optical coherence angiography (MML-OCA) was able to sensitively detect PDT-induced microvascular alterations in the mouse ear tumour model CT26. Histological analysis showed that the main mechanisms of vascular PDT was thrombosis of blood vessels and hemorrhage, which agrees with angiographic imaging by MML-OCA. Relationship between MML-OCA-detected early microvascular damage post PDT (within 24 hours) and tumour regression/regrowth was confirmed by histology. The advantages of MML-OCA such as direct image acquisition, fast processing, robust and affordable system opto-electronics, and label-free high contrast 3D visualization of the microvasculature suggest attractive possibilities of this method in practical clinical monitoring of cancer therapies with microvascular involvement. PMID:28148963

  16. Polarization sensitive optical coherence tomography detection method

    Energy Technology Data Exchange (ETDEWEB)

    Everett, M J; Sathyam, U S; Colston, B W; DaSilva, L B; Fried, D; Ragadio, J N; Featherstone, J D B

    1999-05-12

    This study demonstrates the potential of polarization sensitive optical coherence tomography (PS-OCT) for non-invasive in vivo detection and characterization of early, incipient caries lesions. PS-OCT generates cross-sectional images of biological tissue while measuring the effect of the tissue on the polarization state of incident light. Clear discrimination between regions of normal and demineralized enamel is first shown in PS-OCT images of bovine enamel blocks containing well-characterized artificial lesions. High-resolution, cross-sectional images of extracted human teeth are then generated that clearly discriminate between the normal and carious regions on both the smooth and occlusal surfaces. Regions of the teeth that appeared to be demineralized in the PS-OCT images were verified using histological thin sections examined under polarized light microscopy. The PS-OCT system discriminates between normal and carious regions by measuring the polarization state of the back-scattered 1310 nm light, which is affected by the state of demineralization of the enamel. Demineralization of enamel increases the scattereing coefficient, thus depolarizing the incident light. This study shows that PS-OCT has great potential for the detection, characterization, and monitoring of incipient caries lesions.

  17. Spatial coherence at the output of multimode optical fibers.

    Science.gov (United States)

    Efimov, Anatoly

    2014-06-30

    The modulus of the complex degree of coherence is directly measured at the output of a step-index multimode optical fiber using lateral-sheering, delay-dithering Mach-Zehnder interferometer. Pumping the multimode fiber with monochromatic light always results in spatially-coherent output, whereas for the broadband pumping the modal dispersion of the fiber leads to a partially coherent output. While the coherence radius is a function of the numerical aperture only, the residual coherence outside the main peak is an interesting function of two dimensionless parameters: the number of non-degenerate modes and the ratio of the modal dispersion to the coherence time of the source. We develop a simple model describing this residual coherence and verify its predictions experimentally.

  18. Quantum Entanglement and Correlation of Two Qubit Atoms Interacting with the Coherent State Optical Field

    Science.gov (United States)

    Liu, Tang-Kun; Tao, Yu; Shan, Chuan-Jia; Liu, Ji-bing

    2017-10-01

    Using the three criterions of the concurrence, the negative eigenvalue and the geometric quantum discord, we investigate the quantum entanglement and quantum correlation dynamics of two two-level atoms interacting with the coherent state optical field. We discuss the influence of different photon number of the mean square fluctuations on the temporal evolution of the concurrence, the negative eigenvalue and the geometric quantum discord between two atoms when the two atoms are initially in specific three states. The results show that different photon number of the mean square fluctuations can lead to different effects of quantum entanglement and quantum correlation dynamics.

  19. Quantum Entanglement and Correlation of Two Qubit Atoms Interacting with the Coherent State Optical Field

    Science.gov (United States)

    Liu, Tang-Kun; Tao, Yu; Shan, Chuan-Jia; Liu, Ji-bing

    2017-08-01

    Using the three criterions of the concurrence, the negative eigenvalue and the geometric quantum discord, we investigate the quantum entanglement and quantum correlation dynamics of two two-level atoms interacting with the coherent state optical field. We discuss the influence of different photon number of the mean square fluctuations on the temporal evolution of the concurrence, the negative eigenvalue and the geometric quantum discord between two atoms when the two atoms are initially in specific three states. The results show that different photon number of the mean square fluctuations can lead to different effects of quantum entanglement and quantum correlation dynamics.

  20. Editorial . Quantum fluctuations and coherence in optical and atomic structures

    Science.gov (United States)

    Eschner, Jürgen; Gatti, Alessandra; Maître, Agnès; Morigi, Giovanna

    2003-03-01

    From simple interference fringes, over molecular wave packets, to nonlinear optical patterns - the fundamental interaction between light and matter leads to the formation of structures in many areas of atomic and optical physics. Sophisticated technology in experimental quantum optics, as well as modern computational tools available to theorists, have led to spectacular achievements in the investigation of quantum structures. This special issue is dedicated to recent developments in this area. It presents a selection of examples where quantum dynamics, fluctuations, and coherence generate structures in time or in space or where such structures are observed experimentally. The examples range from coherence phenomena in condensed matter, over atoms in optical structures, entanglement in light and matter, to quantum patterns in nonlinear optics and quantum imaging. The combination of such seemingly diverse subjects formed the basis of a successful European TMR network, "Quantum Structures" (visit http://cnqo.phys.strath.ac.uk/~gianluca/QSTRUCT/). This special issue partly re.ects the results and collaborations of the network, going however well beyond its scope by including contributions from a global community and from many related topics which were not addressed directly in the network. The aim of this issue is to present side by side these di.erent topics, all of which are loosely summarized under quantum structures, to highlight their common aspects, their di.erences, and the progress which resulted from the mutual exchange of results, methods, and knowledge. To guide the reader, we have organized the articles into subsections which follow a rough division into structures in material systems and structures in optical .elds. Nevertheless, in the following introduction we point out connections between the contributions which go beyond these usual criteria, thus highlighting the truly interdisciplinary nature of quantum structures. Much of the progress in atom optics

  1. Physical-layer network coding in coherent optical OFDM systems.

    Science.gov (United States)

    Guan, Xun; Chan, Chun-Kit

    2015-04-20

    We present the first experimental demonstration and characterization of the application of optical physical-layer network coding in coherent optical OFDM systems. It combines two optical OFDM frames to share the same link so as to enhance system throughput, while individual OFDM frames can be recovered with digital signal processing at the destined node.

  2. On-chip microwave-to-optical quantum coherent converter based on a superconducting resonator coupled to an electro-optic microresonator

    Science.gov (United States)

    Javerzac-Galy, C.; Plekhanov, K.; Bernier, N. R.; Toth, L. D.; Feofanov, A. K.; Kippenberg, T. J.

    2016-11-01

    We propose a device architecture capable of direct quantum coherent electro-optical conversion of microwave-to-optical photons. The hybrid system consists of a planar superconducting microwave circuit coupled to an integrated whispering-gallery-mode microresonator made from an electro-optical material. We show that by exploiting the large vacuum electric field of the planar microwave resonator, electro-optical (vacuum) coupling strengths g0 as large as ˜2 π O (10 -100 ) kHz are achievable with currently available technology—a more than 3 orders of magnitude improvement over prior designs and realizations. Operating at millikelvin temperatures, such a converter would enable high-efficiency conversion of microwave-to-optical photons. We analyze the added noise and show that maximum quantum coherent conversion efficiency is achieved for a multiphoton cooperativity of unity which can be reached with optical power as low as O (1 ) mW.

  3. Optical coherence tomography and Doppler optical coherence tomography in the gastrointestinal tract

    Institute of Scientific and Technical Information of China (English)

    Eugen Osiac; Adrian S(a)ftoiu; Dan Ionut Gheonea; Ion Mandrila; Radu Angelescu

    2011-01-01

    Optical coherence tomography(OCT)is a noninvasive,high-resolution,high-potential imaging method that has recently been introduced into medical investigations.A growing number of studies have used this technique in the field of gastroenterology in order to assist classical analyses.Lately,3D-imaging and Doppler capabilities have been developed in different configurations,which make this type of investigation more attractive.This paper reviews the principles and characteristics of OCT and Doppler-OCT in connection with analyses of the detection of normal and pathological structures,and with the possibility to investigate angiogenesis in the gastrointestinal tract.

  4. Quantum dot-micropillars: a bright source of coherent single photons

    DEFF Research Database (Denmark)

    Unsleber, Sebastian; He, Yu-Ming; Maier, Sebastian

    2016-01-01

    We present the efficient generation of coherent single photons based on quantum dots in micropillars. We utilize a scalable lithography scheme leading to quantum dot-micropillar devices with 74% extraction efficiency. Via pulsed strict resonant pumping, we show an indistinguishability...... of consecutively emitted photons up to 98.5%....

  5. Three-Dimensional Optical Coherence Tomography (3D OCT) Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Applied Science Innovations, Inc. proposes to develop a new tool of 3D optical coherence tomography (OCT) for cellular level imaging at video frame rates and...

  6. Three-Dimensional Optical Coherence Tomography (3D OCT) Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Applied Science Innovations, Inc. proposes a new tool of 3D optical coherence tomography (OCT) for cellular level imaging at video frame rates and dramatically...

  7. Depth profilometry via multiplexed optical high-coherence interferometry

    National Research Council Canada - National Science Library

    Kazemzadeh, Farnoud; Wong, Alexander; Behr, Bradford B; Hajian, Arsen R

    2015-01-01

    ... such as defect detection, corrosion assessment, and dental assessment to name a few. In this study, we investigate the feasibility of depth profilometry using an Multiplexed Optical High-coherence Interferometry MOHI instrument...

  8. Realization of non-linear coherent states by photonic lattices

    Directory of Open Access Journals (Sweden)

    Shahram Dehdashti

    2015-06-01

    Full Text Available In this paper, first, by introducing Holstein-Primakoff representation of α-deformed algebra, we achieve the associated non-linear coherent states, including su(2 and su(1, 1 coherent states. Second, by using waveguide lattices with specific coupling coefficients between neighbouring channels, we generate these non-linear coherent states. In the case of positive values of α, we indicate that the Hilbert size space is finite; therefore, we construct this coherent state with finite channels of waveguide lattices. Finally, we study the field distribution behaviours of these coherent states, by using Mandel Q parameter.

  9. Realization of non-linear coherent states by photonic lattices

    Energy Technology Data Exchange (ETDEWEB)

    Dehdashti, Shahram, E-mail: shdehdashti@zju.edu.cn; Li, Rujiang; Chen, Hongsheng, E-mail: hansomchen@zju.edu.cn [State Key Laboratory of Modern Optical Instrumentations, Zhejiang University, Hangzhou 310027 (China); The Electromagnetics Academy at Zhejiang University, Zhejiang University, Hangzhou 310027 (China); Liu, Jiarui, E-mail: jrliu@zju.edu.cn; Yu, Faxin [School of Aeronautics and Astronautics, Zhejiang University, Hangzhou 310027 (China)

    2015-06-15

    In this paper, first, by introducing Holstein-Primakoff representation of α-deformed algebra, we achieve the associated non-linear coherent states, including su(2) and su(1, 1) coherent states. Second, by using waveguide lattices with specific coupling coefficients between neighbouring channels, we generate these non-linear coherent states. In the case of positive values of α, we indicate that the Hilbert size space is finite; therefore, we construct this coherent state with finite channels of waveguide lattices. Finally, we study the field distribution behaviours of these coherent states, by using Mandel Q parameter.

  10. Fiber-diffraction Interferometer using Coherent Fiber Optic Taper

    CERN Document Server

    Kihm, Hagyong

    2010-01-01

    We present a fiber-diffraction interferometer using a coherent fiber optic taper for optical testing in an uncontrolled environment. We use a coherent fiber optic taper and a single-mode fiber having thermally-expanded core. Part of the measurement wave coming from a test target is condensed through a fiber optic taper and spatially filtered from a single-mode fiber to be reference wave. Vibration of the cavity between the target and the interferometer probe is common to both reference and measurement waves, thus the interference fringe is stabilized in an optical way. Generation of the reference wave is stable even with the target movement. Focus shift of the input measurement wave is desensitized by a coherent fiber optic taper.

  11. On-chip coherent conversion of photonic quantum entanglement between different degrees of freedom.

    Science.gov (United States)

    Feng, Lan-Tian; Zhang, Ming; Zhou, Zhi-Yuan; Li, Ming; Xiong, Xiao; Yu, Le; Shi, Bao-Sen; Guo, Guo-Ping; Dai, Dao-Xin; Ren, Xi-Feng; Guo, Guang-Can

    2016-06-20

    In the quantum world, a single particle can have various degrees of freedom to encode quantum information. Controlling multiple degrees of freedom simultaneously is necessary to describe a particle fully and, therefore, to use it more efficiently. Here we introduce the transverse waveguide-mode degree of freedom to quantum photonic integrated circuits, and demonstrate the coherent conversion of a photonic quantum state between path, polarization and transverse waveguide-mode degrees of freedom on a single chip. The preservation of quantum coherence in these conversion processes is proven by single-photon and two-photon quantum interference using a fibre beam splitter or on-chip beam splitters. These results provide us with the ability to control and convert multiple degrees of freedom of photons for quantum photonic integrated circuit-based quantum information process.

  12. On-chip coherent conversion of photonic quantum entanglement between different degrees of freedom

    Science.gov (United States)

    Feng, Lan-Tian; Zhang, Ming; Zhou, Zhi-Yuan; Li, Ming; Xiong, Xiao; Yu, Le; Shi, Bao-Sen; Guo, Guo-Ping; Dai, Dao-Xin; Ren, Xi-Feng; Guo, Guang-Can

    2016-01-01

    In the quantum world, a single particle can have various degrees of freedom to encode quantum information. Controlling multiple degrees of freedom simultaneously is necessary to describe a particle fully and, therefore, to use it more efficiently. Here we introduce the transverse waveguide-mode degree of freedom to quantum photonic integrated circuits, and demonstrate the coherent conversion of a photonic quantum state between path, polarization and transverse waveguide-mode degrees of freedom on a single chip. The preservation of quantum coherence in these conversion processes is proven by single-photon and two-photon quantum interference using a fibre beam splitter or on-chip beam splitters. These results provide us with the ability to control and convert multiple degrees of freedom of photons for quantum photonic integrated circuit-based quantum information process. PMID:27321821

  13. Volumetric optical coherence microscopy enabled by aberrated optics (Conference Presentation)

    Science.gov (United States)

    Mulligan, Jeffrey A.; Liu, Siyang; Adie, Steven G.

    2017-02-01

    Optical coherence microscopy (OCM) is an interferometric imaging technique that enables high resolution, non-invasive imaging of 3D cell cultures and biological tissues. Volumetric imaging with OCM suffers a trade-off between high transverse resolution and poor depth-of-field resulting from defocus, optical aberrations, and reduced signal collection away from the focal plane. While defocus and aberrations can be compensated with computational methods such as interferometric synthetic aperture microscopy (ISAM) or computational adaptive optics (CAO), reduced signal collection must be physically addressed through optical hardware. Axial scanning of the focus is one approach, but comes at the cost of longer acquisition times, larger datasets, and greater image reconstruction times. Given the capabilities of CAO to compensate for general phase aberrations, we present an alternative method to address the signal collection problem without axial scanning by using intentionally aberrated optical hardware. We demonstrate the use of an astigmatic spectral domain (SD-)OCM imaging system to enable single-acquisition volumetric OCM in 3D cell culture over an extended depth range, compared to a non-aberrated SD-OCM system. The transverse resolution of the non-aberrated and astigmatic imaging systems after application of CAO were 2 um and 2.2 um, respectively. The depth-range of effective signal collection about the nominal focal plane was increased from 100 um in the non-aberrated system to over 300 um in the astigmatic system, extending the range over which useful data may be acquired in a single OCM dataset. We anticipate that this method will enable high-throughput cellular-resolution imaging of dynamic biological systems over extended volumes.

  14. Adaptive optics optical coherence tomography at 1 MHz.

    Science.gov (United States)

    Kocaoglu, Omer P; Turner, Timothy L; Liu, Zhuolin; Miller, Donald T

    2014-12-01

    Image acquisition speed of optical coherence tomography (OCT) remains a fundamental barrier that limits its scientific and clinical utility. Here we demonstrate a novel multi-camera adaptive optics (AO-)OCT system for ophthalmologic use that operates at 1 million A-lines/s at a wavelength of 790 nm with 5.3 μm axial resolution in retinal tissue. Central to the spectral-domain design is a novel detection channel based on four high-speed spectrometers that receive light sequentially from a 1 × 4 optical switch assembly. Absence of moving parts enables ultra-fast (50ns) and precise switching with low insertion loss (-0.18 dB per channel). This manner of control makes use of all available light in the detection channel and avoids camera dead-time, both critical for imaging at high speeds. Additional benefit in signal-to-noise accrues from the larger numerical aperture afforded by the use of AO and yields retinal images of comparable dynamic range to that of clinical OCT. We validated system performance by a series of experiments that included imaging in both model and human eyes. We demonstrated the performance of our MHz AO-OCT system to capture detailed images of individual retinal nerve fiber bundles and cone photoreceptors. This is the fastest ophthalmic OCT system we know of in the 700 to 915 nm spectral band.

  15. Machine learning concepts in coherent optical communication systems

    DEFF Research Database (Denmark)

    Zibar, Darko; Schäffer, Christian G.

    2014-01-01

    Powerful statistical signal processing methods, used by the machine learning community, are addressed and linked to current problems in coherent optical communication. Bayesian filtering methods are presented and applied for nonlinear dynamic state tracking. © 2014 OSA.......Powerful statistical signal processing methods, used by the machine learning community, are addressed and linked to current problems in coherent optical communication. Bayesian filtering methods are presented and applied for nonlinear dynamic state tracking. © 2014 OSA....

  16. Experimental Demonstration of Spectral Intensity Optical Coherence Tomography

    CERN Document Server

    Ryczkowski, Piotr; Friberg, Ari T; Genty, Goëry

    2015-01-01

    We demonstrate experimentally quantum-inspired, spectral-domain intensity optical coherence tomography. We show that the technique allows for both axial resolution improvement and dispersion cancellation compared to conventional optical coherence tomography. The method does not involve scanning and it works with classical light sources and standard photodetectors. The measurements are in excellent agreement with the theoretical predictions. We also propose an approach that enables the elimination of potential artifacts arising from multiple interfaces.

  17. Machine learning concepts in coherent optical communication systems

    DEFF Research Database (Denmark)

    Zibar, Darko; Schäffer, Christian G.

    2014-01-01

    Powerful statistical signal processing methods, used by the machine learning community, are addressed and linked to current problems in coherent optical communication. Bayesian filtering methods are presented and applied for nonlinear dynamic state tracking. © 2014 OSA.......Powerful statistical signal processing methods, used by the machine learning community, are addressed and linked to current problems in coherent optical communication. Bayesian filtering methods are presented and applied for nonlinear dynamic state tracking. © 2014 OSA....

  18. Atomic coherence control on the entanglement of two atoms in two-photon processes

    Institute of Scientific and Technical Information of China (English)

    Hu Yao-Hua; Fang Mao-Fa; Wu Qin

    2007-01-01

    Considering two identical two-level atoms interacting with a single-mode thermal field through two-photon processes, this paper studies the atomic coherence control on the entanglement between two two-level atoms, and finds that the entanglement is greatly enhanced due to the initial atomic coherence. The results show that the entanglement can be manipulated by changing the initial parameters of the system, such as the superposition coefficients and the relative phases of the initial atomic coherent state and the mean photon number of the cavity field.

  19. Quantum optics with quantum dots in photonic nanowires

    DEFF Research Database (Denmark)

    We will review recent studies performed on InAs quantum dots embedded in GaAs photonic wires, which highlight the strong interest of the photonic wire geometry for quantum optics experiments and quantum optoelectronic devices.......We will review recent studies performed on InAs quantum dots embedded in GaAs photonic wires, which highlight the strong interest of the photonic wire geometry for quantum optics experiments and quantum optoelectronic devices....

  20. Quantum Optics with Quantum Dots in Photonic Nanowires

    DEFF Research Database (Denmark)

    Gérard, J.-M.; Claudon, J.; Bleuse, J.;

    2011-01-01

    We review recent studies performed on InAs quantum dots embedded in GaAs photonic wires, which highlight the strong interest of the photonic wire geometry for quantum optics experiments and quantum optoelectronic devices.......We review recent studies performed on InAs quantum dots embedded in GaAs photonic wires, which highlight the strong interest of the photonic wire geometry for quantum optics experiments and quantum optoelectronic devices....

  1. A new type of photon-added squeezed coherent state and its statistical properties

    Institute of Scientific and Technical Information of China (English)

    Zhou Jun; Fan Hong-Yi; Song Jun

    2012-01-01

    We construct a new type of photon-added squeezed coherent state generated by repeatedly operating the bosonic creation operator on a new type of squeezed coherent state [Fan H Y and Xiao M 1996 Phys.Lett.A 220 81].We find that its normalization factor is related to single-variable Hermite polynomials.Furthermore,we investigate its statistical properties,such as Mandel's Q parameter,photon-number distribution,and Wigner function.The nonclassicality is displayed in terms of the intense oscillation of photon-number distribution and the negativity of the Wigner function.

  2. Coherent photon scattering background in sub-GeV /c2 direct dark matter searches

    Science.gov (United States)

    Robinson, Alan E.

    2017-01-01

    Proposed dark matter detectors with eV-scale sensitivities will detect a large background of atomic (nuclear) recoils from coherent photon scattering of MeV-scale photons. This background climbs steeply below ˜10 eV , far exceeding the declining rate of low-energy Compton recoils. The upcoming generation of dark matter detectors will not be limited by this background, but further development of eV-scale and sub-eV detectors will require strategies, including the use of low nuclear mass target materials, to maximize dark matter sensitivity while minimizing the coherent photon scattering background.

  3. Anterior Segment Tomography with the Cirrus Optical Coherence Tomography

    Directory of Open Access Journals (Sweden)

    Eduardo B. Rodrigues

    2012-01-01

    Full Text Available Optical coherence tomography (OCT is an optical acquisition method to examine biological tissues. In recent years, OCT has become an important imaging technology used in diagnosing and following macular pathologies. Further development enabled application of optical coherence tomography in evaluation of the integrity of the nerve fiber layer, optic nerve cupping, anterior chamber angle, or corneal topography. In this manuscript we overview the use of OCT in the clinical practice to enable corneal, iris, ciliary body, and angle evaluation and diagnostics.

  4. Bandpass sampling in heterodyne receivers for coherent optical access networks.

    Science.gov (United States)

    Bakopoulos, Paraskevas; Dris, Stefanos; Schrenk, Bernhard; Lazarou, Ioannis; Avramopoulos, Hercules

    2012-12-31

    A novel digital receiver architecture for coherent heterodyne-detected optical signals is presented. It demonstrates the application of bandpass sampling in an optical communications context, to overcome the high sampling rate requirement of conventional receivers (more than twice the signal bandwidth). The concept is targeted for WDM coherent optical access networks, where applying heterodyne detection constitutes a promising approach to reducing optical hardware complexity. The validity of the concept is experimentally assessed in a 76 km WDM-PON scenario, where the developed DSP achieves a 50% ADC rate reduction with penalty-free operation.

  5. Optical Coherence Tomography and Optical Coherence Tomography Angiography in Monitoring Coats’ Disease

    Directory of Open Access Journals (Sweden)

    Wojciech Hautz

    2017-01-01

    Full Text Available Purpose. The aim of this study was to evaluate the usefulness of optical coherence tomography (OCT and optical coherence tomography angiography (OCTA in monitoring pediatric patients with Coats’ disease. Material and Methods. This retrospective study included 9 Caucasian patients receiving treatment for Coats’ disease at the Children’s Memorial Health Institute Ophthalmology Department between December 2014 and May 2016. The course of the disease was monitored with OCTA in combination with OCT and fluorescein angiography (FA. Results. OCT B-scans obtained in all patients correlated with FA findings. Reliable OCTA images were obtained in 8 patients. In one patient, numerous artifacts due to poor visual acuity and retinal detachment confounded the interpretation of findings. Conclusions. OCTA and OCT, in combination with FA, are useful in Coats’ disease diagnostics and treatment monitoring. As noninvasive methods, OCT and OCTA may be performed more often than FA, which enable precise monitoring of the disease and making decisions as to its further treatment.

  6. Imaging Granulomatous Lesions with Optical Coherence Tomography

    Directory of Open Access Journals (Sweden)

    Christina Banzhaf

    2012-01-01

    Full Text Available Aim: To investigate and compare the presentation of granulomatous lesions in optical coherence tomography (OCT images and compare this to previous studies of nonmelanoma skin tumors. Methods: Two patients with granulomas, tophi and granuloma annulare (GA, respectively, were photographed digitally, OCT-scanned and biopsied in the said order. Normal skin was OCT-scanned for comparison, but not biopsied. The OCT images from each lesion were compared with their histologic images as well as with OCT images with similar characteristics obtained from nonmelanoma skin tumors. Results: The OCT images of the tophi showed hyperreflective, rounded cloud-like structures in dermis, their upper part sharply delineated by a hyporeflective fringe. The deeper areas appeared blurred. The crystalline structures were delineated by a hyporeflective fringe. OCT images of GA showed two different structures in dermis: a hyporeflective rounded one, and one that was lobulated and wing-like. Conclusion: Granulomatous tissue surrounding urate deposits appeared as a clear hyporeflective fringe surrounding a light, hyperreflective area. The urate crystals appeared as hyperreflective areas, shielding the deeper part of dermis, meaning OCT could only visualize the upper part of the lesions. The lobulated, wing-like structure in GA may resemble diffuse GA or a dense lymphocytic infiltrate as seen on histology. The rounded structure in GA may represent an actual granuloma or either diffuse GA or a dense lymphocytic infiltrate as described above. This case suggests that OCT images granulomatous tissue as absorbent, hyporeflective areas, and urate crystals appear as reflective areas, obscuring the underlying tissue. In GA a new image shape looking like a wing has been found. The frequency, specificity and sensitivity of this new pattern in OCT imaging will require further studies.

  7. En-face optical coherence tomography revival

    Science.gov (United States)

    Bradu, Adrian; Kapinchev, Konstantin; Barnes, Frederick; Podoleanu, Adrian Gh.

    2016-03-01

    Quite recently, we introduced a novel Optical Coherence Tomography (OCT) method, termed as Master Slave OCT (MS-OCT), especially to deliver en-face images. MS-OCT operates like a time domain OCT, selecting signal from a selected depth only while scanning the laser beam across the sample. Time domain OCT allows real time production of an en-face image, although relatively slowly. As a major advance, the Master Slave method allows collection of signals from any number of depths, as required by the user. MS-OCT is an OCT method that does not require resampling of data and can be used to deliver en-face images from several depths simultaneously. However, as the MS-OCT method requires important computational resources, the number of multiple depth en-face images produced in real-time is limited. Here, we demonstrate that taking advantage of the parallel processing feature of the MS-OCT technology by harnessing the capabilities of graphics processing units (GPU)s, information from 384 depth positions is acquired in one raster with real time display of 40 en-face OCT images. These exhibit comparable resolution and sensitivity to the images produced using the traditional Fourier domain based method. The GPU facilitates versatile real time selection of parameters, such as the depth positions of the 40 images out of a set of 384 depth locations, as well as their axial resolution. Here, we present in parallel with the 40 en-face OCT images of a human tooth, a confocal microscopy lookalike image, together with two B-scan OCT images along rectangular directions.

  8. Self-Optical Coherence Tomography and Angiography

    Directory of Open Access Journals (Sweden)

    Ahmad M. Mansour

    2017-02-01

    Full Text Available Purpose: To present a new concept of self-optical coherence tomography (OCT and self-OCT angiography. Methods: The operator sits in the patient seat and manipulates the instrument body via the joystick with the dominant hand, while the dominant index is ready to press the capture button and while focusing on the fixation target. One senior ophthalmologist judged various OCT machines for ease of self-scan during a major ophthalmic convention. Separately, self-scans were also captured using a single OCT machine by one senior ophthalmologist and 5 junior optometrists and the scans were analyzed for both centration and image quality value (IQV, and compared to regular scans done by an operator. Results: Ten available OCT machines were tested for their ability to allow self-OCT. Machines that had one or more features of auto-alignment, auto-focus, and auto-shoot were ideal for self-OCT or self-OCT angiography. Self-scans done by the ophthalmologist (total 27 scans of right eye, mean IQV = 32.6, and 24 left eyes, mean IQV = 37.3, done over 9 months and 5 optometrists (total 24 scans, mean 34.8 done in one session were comparable to scans (total 11, mean IQV = 38.1 done by an operator for image quality. Decentration was very common in self-scans of the macula (37% right eye and 46% left eye versus 0% for scans of the right eye done by an operator. Conclusions: Self-OCT scans of the macular region can be done with good image quality but are often decentered. Advantages include privacy, potential use by ophthalmic health professionals, airspace station officers, and possible future home self-imaging of macula.

  9. Carious growth monitoring with optical coherence tomography

    Science.gov (United States)

    Freitas, A. Z.; Zezell, D. M.; Mayer, M. P. A.; Ribeiro, A. C.; Gomes, A. S. L.; Vieira, N. D., Jr.

    2006-02-01

    Optical Coherence Tomography was used to monitor subsurface caries evolution process in vitro. Human tooth was used and bacteria were employed to induce caries lesions. Twenty-five human third molars, were used in this study. The teeth were cut longitudinally at mesio-distal direction; the surfaces were coated with nail varnish except for two squared windows (2x4 mm); at the cement-enamel junction. Artificial lesions were induced by a S. Mutans microbiological culture. The samples (N = 50) were divided into groups according to the demineralization time: 3, 5, 7, 9 and 11 days. The culture medium, was changed each 48 hours. After the demineralization process the samples were rinsed with double-deionized water and stored in a humid environment. The OCT system was implemented with average power of 96 μW in the sample arm, providing a 23 μm of axial resolution. The images were produced with lateral scans step of 10 μm. The detection system was composed by a detector, a demodulator and a computer. With the images generated by OCT it was possible to determine the lesion depth as function of sample exposition time to microbiological culture. We observed that the depth of the lesion in the root dentine increased from 70 μm to 230 μm, depending of exposure time, and follows the bacterial population growth law. This OCT system accurately depicts hard dental tissue and it was able to detect early caries in its structure, providing a powerful contactless high resolution image of lesions.

  10. Optical forces on small particles from partially coherent light

    CERN Document Server

    Auñón, Juan Miguel

    2012-01-01

    We put forward a theory on the optical force exerted upon a dipolar particle by a stationary and ergodic partially coherent light ?eld. We show through a rigorous analysis that the ensemble averaged electromagnetic force is given in terms of a partial gradient of the space variable diagonal elements of the coherence tensor. Further, by following this result we characterize the conservative and non-conservative components of this force. In addition, we establish the propagation law for the optical force in terms of the coherence function of light at a di?raction plane. This permits us to evaluate the e?ect of the degree of coherence on the force components by using the archetypical con?guration of Young's two apertures di?raction pattern, so often employed to characterize coherence of waves.

  11. Applications of Doppler optical coherence tomography

    Science.gov (United States)

    Xu, Zhiqiang

    A major development in biomedical imaging in the last decade has been optical coherence tomography (OCT). This technique enables microscale resolution, depth resolved imaging of the detailed morphology of transparent and nontransparent biological tissue in a noncontact and quasi-noninvasive way. In the first part of this dissertation, we will describe the development and the performance of our home-made OCT systems working with different wavelength regions based on free-space and optical fiber Michelson interferometers. The second part will focus on Doppler OCT (DOCT), an important extension of OCT, which enables the simultaneous evaluation of the structural information and of the fluid flow distribution at a localized position beneath the sample surface. Much effort has been spent during the past few years in our laboratory aimed at providing more accurate velocity measurements with an extended dynamic range. We also applied our technique in different research areas such as microfluidics and hemodynamics. Investigations on the optical properties of the biological tissues (such as absorption and scattering) corresponding to different center wavelengths, have been performed in our laboratory. We used a 10 femtosecond Ti:sapphire laser centered at about 810 nm associated with a free-space Michelson interferometer. The infrared sources were centered at about 1310 and 1560 nm with all-fiber interferometers. Comparative studies using three different sources for several in vitro biological tissues based on a graphical method illustrated how the optical properties affect the quality of the OCT images in terms of the penetration depth and backscattering intensity. We have shown the advantage of working with 810-nm emission wavelength for good backscattering amplitude and contrast, while sources emitting at 1570 nm give good penetration depth. The 1330-nm sources provide a good compromise between the two. Therefore, the choice of the source will ultimately determine the

  12. Digital Signal Processing for Optical Coherent Communication Systems

    DEFF Research Database (Denmark)

    Zhang, Xu

    In this thesis, digital signal processing (DSP) algorithms are studied to compensate for physical layer impairments in optical fiber coherent communication systems. The physical layer impairments investigated in this thesis include optical fiber chromatic dispersion, polarization demultiplexing......, light sources frequency and phase offset and phase noise. The studied DSP algorithms are considered as key building blocks in digital coherent receivers for the next generation of optical communication systems such as 112-Gb/s dual polarization (DP) quadrature phase shift keying (QPSK) optical...... spectrum narrowing tolerance 112-Gb/s DP-QPSK optical coherent systems using digital adaptive equalizer. The demonstrated results show that off-line DSP algorithms are able to reduce the bit error rate (BER) penalty induced by signal spectrum narrowing. Third, we also investigate bi...

  13. Coupled cavity QED for coherent control of photon transmission (I): Green function approach for hybrid systems with two-level doping

    CERN Document Server

    Hu, F M; Sun, C P; Zhou, L; Shi, Tao; Zhou, Lan

    2006-01-01

    This is the first one of a series of our papers theoretically studying the coherent control of photon transmission along the coupled resonator optical waveguide (CROW) by doping artificial atoms for various hybrid structures. We will provide the several approaches correspondingly based on Green function, the mean field method and spin wave theory et al. In the present paper we adopt the two-time Green function approach to study the coherent transmission photon in a CROW with homogeneous couplings, each cavity of which is doped by a two-level artificial atom. We calculate the two-time correlation function for photon in the weak-coupling case. Its poles predict the exact dispersion relation, which results in the group velocity coherently controlled by the collective excitation of the doping atoms. We emphasize the role of the population inversion of doping atoms induced by some polarization mechanism.

  14. Classifying murine glomerulonephritis using optical coherence tomography and optical coherence elastography.

    Science.gov (United States)

    Liu, Chih-Hao; Du, Yong; Singh, Manmohan; Wu, Chen; Han, Zhaolong; Li, Jiasong; Chang, Anthony; Mohan, Chandra; Larin, Kirill V

    2016-08-01

    Acute glomerulonephritis caused by antiglomerular basement membrane marked by high mortality. The primary reason for this is delayed diagnosis via blood examination, urine analysis, tissue biopsy, or ultrasound and X-ray computed tomography imaging. Blood, urine, and tissue-based diagnoses can be time consuming, while ultrasound and CT imaging have relatively low spatial resolution, with reduced sensitivity. Optical coherence tomography is a noninvasive and high-resolution imaging technique that provides superior spatial resolution (micrometer scale) as compared to ultrasound and CT. Changes in tissue properties can be detected based on the optical metrics analyzed from the OCT signals, such as optical attenuation and speckle variance. Furthermore, OCT does not rely on ionizing radiation as with CT imaging. In addition to structural changes, the elasticity of the kidney can significantly change due to nephritis. In this work, OCT has been utilized to quantify the difference in tissue properties between healthy and nephritic murine kidneys. Although OCT imaging could identify the diseased tissue, its classification accuracy is clinically inadequate. By combining optical metrics with elasticity, the classification accuracy improves from 76% to 95%. These results show that OCT combined with OCE can be a powerful tool for identifying and classifying nephritis. Therefore, the OCT/OCE method could potentially be used as a minimally invasive tool for longitudinal studies during the progression and therapy of glomerulonephritis as well as complement and, perhaps, substitute highly invasive tissue biopsies. Elastic-wave propagation in mouse healthy and nephritic kidneys.

  15. Coherent Optical Memory with High Storage Efficiency and Large Fractional Delay

    CERN Document Server

    Chen, Yi-Hsin; Wang, I-Chung; Du, Shengwang; Chen, Yong-Fan; Chen, Ying-Cheng; Yu, Ite A

    2012-01-01

    A high-storage efficiency and long-live quantum memory for photons is an essential component in long-distance quantum communication and optical quantum computation. Here, we report a 78% storage efficiency of light pulses in a cold atomic medium based on the effect of electromagnetically induced transparency (EIT). At 50% storage efficiency, we obtain a fractional delay of 74, which is the best up-to-date record. The classical fidelity of the recalled pulse is better than 90% and nearly independent of the storage time, as confirmed by the direct measurement of phase evolution of the output light pulse with a beat-note interferometer. Such excellent phase coherence between the stored and recalled light pulses suggests that the current result can be readily applied to single photon wave packets. Our work significantly advances the technology of EIT-based optical memory and may find practical applications in long-distance quantum communication and optical quantum computation.

  16. High performance fiber-based optical coherent detection

    Science.gov (United States)

    Chen, Youming

    The sensitivity of signal detection is of major interest for optical high speed communication systems and LIght Detection And Ranging (lidar) systems. Sensitive receivers in fiber-optical networks can reduce transmitter power or amplifier amplification requirements and extend link spans. High receiver sensitivity allows links to be established over long distances in deep space satellite communication systems and large atmospheric attenuation to be overcome in terrestrial free space communications. For lidar systems, the sensitivity of signal detection determines how far and how accurately the lidar can detect the remote objects. Optical receivers employ either coherent or direct detection. In addition to amplitude, coherent detection extracts frequency and phase information from received signals, whereas direct detection extracts the received pulse amplitude only. In theory, coherent detection should yield the highest receiver sensitivity. Another possible technique to improve detection sensitivity is to employ a fiber preamplifier. This technique has been successfully demonstrated in direct detection systems but not in the coherent detection systems. Due to the existence of amplified spontaneous emission (ASE) inside the amplifier, the sensitivity of coherent detection varies with the data rate or pulse rate. For this reason, optically preamplified coherent detection is not used in applications as commonly as optically preamplified direct detection. We investigate the performance of coherent detection employing a fiber amplifier and time-domain-filter. The fiber amplifier is used as the optical preamplifier of the coherent detection system. To reduce the noise induced by the preamplifier to a maximum extent, we investigate the noise properties for both a single pass amplifier and a double pass amplifier. The relative intensity noise and linewidth broadening caused by ASE have been experimentally characterized. The results show that the double pass amplifier has

  17. Controllable Photonic Band Gap and Defect Mode in a 1D CO2-Laser Optical Lattice

    Institute of Scientific and Technical Information of China (English)

    ZHOU Qi; YIN Jian-Ping

    2008-01-01

    We Dropose a new method to form a novel controllable photonic crystal with cold atoms and study the photonic band gap(PBG)of an infinite 1D CO2-laser optical lattice of 85Rb atoms under the condition of quantum coherence.A significant gap generated near the resonant frequency of the atom is founded and its dependence on physical parameters is also discussed.Using the eigenquation of defect mode,we calculate the defect mode when a defect is introduced into such a lattice.Our study shows that the proposed new method can be used to optically probe optical lattice in situ and to design some novel and controllable photonic crystals.

  18. Optomechanical measurement of photon spin angular momentum and optical torque in integrated photonic devices.

    Science.gov (United States)

    He, Li; Li, Huan; Li, Mo

    2016-09-01

    Photons carry linear momentum and spin angular momentum when circularly or elliptically polarized. During light-matter interaction, transfer of linear momentum leads to optical forces, whereas transfer of angular momentum induces optical torque. Optical forces including radiation pressure and gradient forces have long been used in optical tweezers and laser cooling. In nanophotonic devices, optical forces can be significantly enhanced, leading to unprecedented optomechanical effects in both classical and quantum regimes. In contrast, to date, the angular momentum of light and the optical torque effect have only been used in optical tweezers but remain unexplored in integrated photonics. We demonstrate the measurement of the spin angular momentum of photons propagating in a birefringent waveguide and the use of optical torque to actuate rotational motion of an optomechanical device. We show that the sign and magnitude of the optical torque are determined by the photon polarization states that are synthesized on the chip. Our study reveals the mechanical effect of photon's polarization degree of freedom and demonstrates its control in integrated photonic devices. Exploiting optical torque and optomechanical interaction with photon angular momentum can lead to torsional cavity optomechanics and optomechanical photon spin-orbit coupling, as well as applications such as optomechanical gyroscopes and torsional magnetometry.

  19. Spectral-domain optical coherence tomography on a silicon chip

    NARCIS (Netherlands)

    Akca, Bakiye Imran

    2012-01-01

    Optical coherence tomography (OCT) is a non-invasive optical technique for high-resolution cross-sectional imaging of specimens, with many applications in clinical medicine and industry (e.g. materials testing, quality assurance, and process control). Current state-of-the-art OCT systems operate in

  20. Phase-coherent all-optical frequency division by three

    NARCIS (Netherlands)

    Lee, Dong-Hoon; Klein, M.E.; Meyn, Jan-Peter; Wallenstein, Richard; Gross, P.; Boller, Klaus J.

    2003-01-01

    The properties of all-optical phase-coherent frequency division by 3, based on a self-phase-locked continuous-wave (cw) optical parametric oscillator (OPO), are investigated theoretically and experimentally. The frequency to be divided is provided by a diode laser master-oscillator power-amplifier

  1. OPTICAL COHERENCE TOMOGRAPHY IN JUVENILE NEURONAL CEROID LIPOFUSCINOSIS

    DEFF Research Database (Denmark)

    Hansen, Michael S.; Hove, Marianne N; Jensen, Hanne;

    2016-01-01

    PURPOSE: To report optical coherence tomography findings obtained in two patients with juvenile neuronal ceroid lipofuscinosis. METHODS: Two case reports. RESULTS: Two 7-year-old girls presented with decreased visual acuity, clumsiness, night blindness, and behavioral problems. Optical coherence...... tomography showed an overall reduction in thickness of the central retina, as well as the outer and the inner retinal layers. The degenerative retinal changes were the same, despite different mutations in the CLN3 gene. CONCLUSION: In these rare cases of juvenile neuronal ceroid lipofuscinosis, optical...

  2. Amplifier Noise Based Optical Steganography with Coherent Detection

    Science.gov (United States)

    Wu, Ben; Chang, Matthew P.; Caldwell, Naomi R.; Caldwell, Myles E.; Prucnal, Paul R.

    2014-12-01

    We summarize the principle and experimental setup of optical steganography based on amplified spontaneous emission (ASE) noise. Using ASE noise as the signal carrier, optical steganography effectively hides a stealth channel in both the time domain and the frequency domain. Coherent detection is used at the receiver of the stealth channel. Because ASE noise has short coherence length and random phase, it only interferes with itself within a very short range. Coherent detection requires the stealth transmitter and stealth receiver to precisely match the optical delay,which generates a large key space for the stealth channel. Several methods to further improve optical steganography, signal to noise ratio, compatibility with the public channel, and applications of the stealth channel are also summarized in this review paper.

  3. Coherence and statistics of a one-atom laser in a photonic crystal microcavity

    Energy Technology Data Exchange (ETDEWEB)

    Guo, Xiaoyong; Ren, Zhongzhou [Department of Physics, Nanjing University, Nanjing 210008 (China); Lue, Shuchen, E-mail: lushuchen63@yahoo.com.c [Province Key Laboratory of Nanosize Functional Materials, School of Physics and Electronic Engineering, Harbin Normal University, Harbin 150080 (China)

    2010-11-28

    Through calculating the quantum degree of second-order coherence and photon number distribution numerically, we investigate the coherence and statistics of a one-atom laser where a coherently driven two-level atom is coupled to a photonic crystal microcavity. By going beyond the previous theoretical studies, we show that in the presence of non-secular terms the cavity field displays a variable degree of second-order coherence as a function of discontinuities in the photonic density of states. The cavity field is characterized by photon antibunching and sub-Poissonian statistics for large discontinuities. In the case of a vanishing photonic density of states on the lower Mollow sideband, we can obtain only weak antibunching. If the jump in the photonic density of states is small, the bunching and super-Poissonian statistics field is generated in the cavity. Consequently, the cavity field exhibits certain non-classical features when non-secular interaction is included into the dynamics of the system. The theoretical analysis and numerical calculations presented here coincide with recent experimental observations.

  4. Access to long-term optical memories using photon echoes retrieved from electron spins in semiconductor quantum wells

    Science.gov (United States)

    Poltavtsev, S. V.; Langer, L.; Yugova, I. A.; Salewski, M.; Kapitonov, Y. V.; Yakovlev, D. R.; Karczewski, G.; Wojtowicz, T.; Akimov, I. A.; Bayer, M.

    2016-10-01

    We use spontaneous (two-pulse) and stimulated (three-pulse) photon echoes for studying the coherent evolution of optically excited ensemble of trions which are localized in semiconductor CdTe/CdMgTe quantum well. Application of transverse magnetic field leads to the Larmor precession of the resident electron spins, which shuffles optically induced polarization between optically accessible and inaccessible states. This results in several spectacular phenomena. First, magnetic field induces oscillations of spontaneous photon echo amplitude. Second, in three-pulse excitation scheme, the photon echo decay is extended by several orders of magnitude. In this study, short-lived optical excitation which is created by the first pulse is coherently transferred into a long-lived electron spin state using the second optical pulse. This coherent spin state of electron ensemble persists much longer than any optical excitation in the system, preserving information on initial optical field, which can be retrieved as a photon echo by means of third optical pulse.

  5. Quantum fuel with multilevel atomic coherence for ultrahigh specific work in a photonic Carnot engine

    Science.gov (United States)

    Türkpençe, Deniz; Müstecaplıoǧlu, Özgür E.

    2016-01-01

    We investigate scaling of work and efficiency of a photonic Carnot engine with a number of quantum coherent resources. Specifically, we consider a generalization of the "phaseonium fuel" for the photonic Carnot engine, which was first introduced as a three-level atom with two lower states in a quantum coherent superposition by M. O. Scully, M. Suhail Zubairy, G. S. Agarwal, and H. Walther [Science 299, 862 (2003), 10.1126/science.1078955], to the case of N +1 level atoms with N coherent lower levels. We take into account atomic relaxation and dephasing as well as the cavity loss and derive a coarse-grained master equation to evaluate the work and efficiency analytically. Analytical results are verified by microscopic numerical examination of the thermalization dynamics. We find that efficiency and work scale quadratically with the number of quantum coherent levels. Quantum coherence boost to the specific energy (work output per unit mass of the resource) is a profound fundamental difference of quantum fuel from classical resources. We consider typical modern resonator set ups and conclude that multilevel phaseonium fuel can be utilized to overcome the decoherence in available systems. Preparation of the atomic coherences and the associated cost of coherence are analyzed and the engine operation within the bounds of the second law is verified. Our results bring the photonic Carnot engines much closer to the capabilities of current resonator technologies.

  6. Quantum fuel with multilevel atomic coherence for ultrahigh specific work in a photonic Carnot engine.

    Science.gov (United States)

    Türkpençe, Deniz; Müstecaplıoğlu, Özgür E

    2016-01-01

    We investigate scaling of work and efficiency of a photonic Carnot engine with a number of quantum coherent resources. Specifically, we consider a generalization of the "phaseonium fuel" for the photonic Carnot engine, which was first introduced as a three-level atom with two lower states in a quantum coherent superposition by M. O. Scully, M. Suhail Zubairy, G. S. Agarwal, and H. Walther [Science 299, 862 (2003)SCIEAS0036-807510.1126/science.1078955], to the case of N+1 level atoms with N coherent lower levels. We take into account atomic relaxation and dephasing as well as the cavity loss and derive a coarse-grained master equation to evaluate the work and efficiency analytically. Analytical results are verified by microscopic numerical examination of the thermalization dynamics. We find that efficiency and work scale quadratically with the number of quantum coherent levels. Quantum coherence boost to the specific energy (work output per unit mass of the resource) is a profound fundamental difference of quantum fuel from classical resources. We consider typical modern resonator set ups and conclude that multilevel phaseonium fuel can be utilized to overcome the decoherence in available systems. Preparation of the atomic coherences and the associated cost of coherence are analyzed and the engine operation within the bounds of the second law is verified. Our results bring the photonic Carnot engines much closer to the capabilities of current resonator technologies.

  7. Optomechanical measurement of photon spin angular momentum and optical torque in integrated photonic devices

    CERN Document Server

    He, Li; Li, Mo

    2016-01-01

    Photons carry linear momentum, and spin angular momentum when circularly or elliptically polarized. During light-matter interaction, transfer of linear momentum leads to optical forces, while angular momentum transfer induces optical torque. Optical forces including radiation pressure and gradient forces have long been utilized in optical tweezers and laser cooling. In nanophotonic devices optical forces can be significantly enhanced, leading to unprecedented optomechanical effects in both classical and quantum regimes. In contrast, to date, the angular momentum of light and the optical torque effect remain unexplored in integrated photonics. Here, we demonstrate the measurement of the spin angular momentum of photons propagating in a birefringent waveguide and the use of optical torque to actuate rotational motion of an optomechanical device. We show that the sign and magnitude of the optical torque are determined by the photon polarization states that are synthesized on the chip. Our study reveals the mecha...

  8. Analysis of optical amplifier noise in coherent optical communication systems with optical image rejection receivers

    DEFF Research Database (Denmark)

    Jørgensen, Bo Foged; Mikkelsen, Benny; Mahon, Cathal J.

    1992-01-01

    performance. Two types of optical image rejection receivers are investigated: a novel, all-optical configuration and the conventional, microwave-based configuration. The analysis shows that local oscillator-spontaneous emission beat noise (LO-SP), signal-spontaneous emission beat noise (S-SP), and spontaneous......A detailed theoretical analysis of optical amplifier noise in coherent optical communication systems with heterodyne receivers is presented. The analysis quantifies in particular how optical image rejection receiver configurations reduce the influence of optical amplifier noise on system......-spontaneous beat noise (SP-SP) can all be reduced by 3 dB, thereby doubling the dynamic range of the optical amplifier. A 2.5-dB improvement in dynamic range has been demonstrated experimentally with the all-optical image rejection configuration. The implications of the increased dynamic range thus obtained...

  9. Coherent optical communication using polarization multiple-input-multiple-output.

    Science.gov (United States)

    Han, Yan; Li, Guifang

    2005-09-19

    Polarization-division multiplexed (PDM) optical signals can potentially be demultiplexed by coherent detection and digital signal processing without using optical dynamic polarization control at the receiver. In this paper, we show that optical communications using PDM is analogous to wireless communications using multiple-input-multiple-output (MIMO) antennae and thus algorithms for channel estimation in wireless MIMO can be ready applied to optical polarization MIMO (PMIMO). Combined with frequency offset and phase estimation algorithms, simulations show that PDM quadrature phase-shift keying signals can be coherently detected by the proposed scheme using commercial semiconductor lasers while no optical phase locking and polarization control are required. This analogy further suggests the potential application of space-time coding in wireless communications to optical polarization MIMO systems and relates the problem of polarization-mode dispersion in fiber transmission to the multi-path propagation in wireless communications.

  10. Digital coherent detection of multi-gigabit 40 GHz carrier frequency radio-over-fiber signals using photonic downconversion

    DEFF Research Database (Denmark)

    Caballero Jambrina, Antonio; Zibar, Darko; Tafur Monroy, Idelfonso

    Detection of high speed radio signals is a challenge for next generation radio-over-fiber links, requiring high bandwidth and linearity in the receiver. By using photonic downconversion in a coherent receiver, it is possible to detect signals exceeding the electrical bandwidth of the receiver......, by performing the mixing of the radio signal with a free-running local oscillator in the optical domain. In this paper we present the experimental emonstration of high bitrate 16-QAM signal detection, up to 4 Gb/s, at 40 GHz carrier frequency, using low bandwidth electronics....

  11. CHOROIDAL IMAGING USING SPECTRAL-DOMAIN OPTICAL COHERENCE TOMOGRAPHY

    Science.gov (United States)

    Regatieri, Caio V.; Branchini, Lauren; Fujimoto, James G.; Duker, Jay S.

    2012-01-01

    Background A structurally and functionally normal choroidal vasculature is essential for retinal function. Therefore, a precise clinical understanding of choroidal morphology should be important for understanding many retinal and choroidal diseases. Methods PUBMED (http://www.ncbi.nlm.nih.gov/sites/entrez?db=pubmed) was used for most of the literature search for this article. The criterion for inclusion of an article in the references for this review was that it included materials about both the clinical and the basic properties of choroidal imaging using spectral-domain optical coherence tomography. Results Recent reports show successful examination and accurate measurement of choroidal thickness in normal and pathologic states using spectral-domain optical coherence tomography systems. This review focuses on the principles of the new technology that make choroidal imaging using optical coherence tomography possible and on the changes that subsequently have been documented to occur in the choroid in various diseases. Additionally, it outlines future directions in choroidal imaging. Conclusion Optical coherence tomography is now proven to be an effective noninvasive tool to evaluate the choroid and to detect choroidal changes in pathologic states. Additionally, choroidal evaluation using optical coherence tomography can be used as a parameter for diagnosis and follow-up. PMID:22487582

  12. Enhancing quantum entanglement for continuous variables by a coherent superposition of photon subtraction and addition

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Su-Yong; Kim, Ho-Joon [Department of Physics, Texas A and M University at Qatar, P.O. Box 23874, Doha (Qatar); Ji, Se-Wan [School of Computational Sciences, Korea Institute for Advanced Study, Seoul 130-012 (Korea, Republic of); Nha, Hyunchul [Department of Physics, Texas A and M University at Qatar, P.O. Box 23874, Doha (Qatar); Institute fuer Quantenphysik, Universitaet Ulm, D-89069 Ulm (Germany)

    2011-07-15

    We investigate how the entanglement properties of a two-mode state can be improved by performing a coherent superposition operation ta+ra{sup {dagger}} of photon subtraction and addition, proposed by Lee and Nha [Phys. Rev. A 82, 053812 (2010)], on each mode. We show that the degree of entanglement, the Einstein-Podolsky-Rosen-type correlation, and the performance of quantum teleportation can be all enhanced for the output state when the coherent operation is applied to a two-mode squeezed state. The effects of the coherent operation are more prominent than those of the mere photon subtraction a and the addition a{sup {dagger}} particularly in the small-squeezing regime, whereas the optimal operation becomes the photon subtraction (case of r=0) in the large-squeezing regime.

  13. Accuracy of optical navigation systems for automatic head surgery: optical tracking versus optical coherence tomography

    Science.gov (United States)

    Díaz Díaz, Jesús; Riva, Mauro H.; Majdani, Omid; Ortmaier, Tobias

    2014-03-01

    The choice of a navigation system highly depends on the medical intervention and its accuracy demands. The most commonly used systems for image guided surgery (IGS) are based on optical and magnetic tracking systems. This paper compares two optical systems in terms of accuracy: state of the art triangulation-based optical tracking (OT) and optical coherence tomography (OCT). We use an experimental setup with a combined OCT and cutting laser, and an external OT. We simulate a robotic assisted surgical intervention, including planning, navigation, and processing, and compare the accuracies reached at a specific target with each navigation system.

  14. Using single photons to improve fiber optic communication systems

    Science.gov (United States)

    Pinto, Armando N.; Silva, Nuno A.; Almeida, Álvaro J.; Muga, Nelson J.

    2014-08-01

    We show how to generate, encode, transmit and detect single photons. By using single photons we can address two of the more challenging problems that communication engineers face nowadays: capacity and security. Indeed, by decreasing the number of photons used to encode each bit, we can efficiently explore the full capacity to carry information of optical fibers, and we can guarantee privacy at the physical layer. We present results for single and entangled photon generation. We encode information in the photons polarization and after transmission we retrieve that information. We discuss the impact of fiber birefringence on the photons polarization.

  15. Quantum Optics with Quantum Dots in Photonic Nanowires

    DEFF Research Database (Denmark)

    Gérard, J. M.; Claudon, J.; Bleuse, J.;

    2012-01-01

    We review recent experimental and theoretical results, which highlight the strong interest of the photonic wire geometry for solid-state quantum optics and quantum optoelectronic devices.......We review recent experimental and theoretical results, which highlight the strong interest of the photonic wire geometry for solid-state quantum optics and quantum optoelectronic devices....

  16. Linear-optics manipulations of photon-loss codes

    CERN Document Server

    Banaszek, K; Banaszek, Konrad; Wasilewski, Wojciech

    2007-01-01

    We discuss codes for protecting logical qubits carried by optical fields from the effects of amplitude damping, i.e. linear photon loss. We demonstrate that the correctability condition for one-photon loss imposes limitations on the range of manipulations than can be implemented with passive linear-optics networks.

  17. Optical probe design with extended depth-of-focus for optical coherence microscopy and optical coherence tomography

    Science.gov (United States)

    Lee, Seungwan; Choi, Minseog; Lee, Eunsung; Jung, Kyu-Dong; Chang, Jong-hyeon; Kim, Woonbae

    2013-03-01

    In this report, Optical probe system for modality, optical coherence tomography (OCT) and optical coherence microscope (OCM), is presented. In order to control the back focal length from 2.2 mm to 27 mm, optical probe is designed using two liquid lenses and several lenses. The narrow depth of focus (DOF) in microscope is extended by phase filter such as cubic filter. The filter is modified so that DOF is extended only In the OCM mode. The section for the extended DOF of probe is controlled by iris. Therefore in OCT mode, the phase filter does not affect on the DOF of lens. In OCM mode, the Gaussian light and modified light will affect the DOF. The probe dimension is less than 4 mm diameter and less than 60 mm long. The scan range of system is 0.88 mm wide, 1 mm deep in the OCT and 510 μm wide, 1 mm deep in the OCM mode. The lens curvature and iris aperture are operated by digital microelectrofluidic lens and iris.

  18. Coupling of erbium dopants to yttrium orthosilicate photonic crystal cavities for on-chip optical quantum memories

    Energy Technology Data Exchange (ETDEWEB)

    Miyazono, Evan; Zhong, Tian; Craiciu, Ioana; Kindem, Jonathan M.; Faraon, Andrei, E-mail: faraon@caltech.edu [T. J. Watson Laboratory of Applied Physics, California Institute of Technology, 1200 E California Blvd, Pasadena, California 91125 (United States)

    2016-01-04

    Erbium dopants in crystals exhibit highly coherent optical transitions well suited for solid-state optical quantum memories operating in the telecom band. Here, we demonstrate coupling of erbium dopant ions in yttrium orthosilicate to a photonic crystal cavity fabricated directly in the host crystal using focused ion beam milling. The coupling leads to reduction of the photoluminescence lifetime and enhancement of the optical depth in microns-long devices, which will enable on-chip quantum memories.

  19. Coupling of erbium dopants to yttrium orthosilicate photonic crystal cavities for on-chip optical quantum memories

    CERN Document Server

    Miyazono, Evan; Craiciu, Ioana; Kindem, Jonathan M; Faraon, Andrei

    2016-01-01

    Erbium dopants in crystals exhibit highly coherent optical transitions well suited for solid-state optical quantum memories operating in the telecom band. Here we demonstrate coupling of erbium dopant ions in yttrium orthosilicate to a photonic crystal cavity fabricated directly in the host crystal using focused ion beam milling. The coupling leads to reduction of the photoluminescence lifetime and enhancement of the optical depth in microns-long devices, which will enable on-chip quantum memories.

  20. Optical coherence tomography of the prostate nerves

    Science.gov (United States)

    Chitchian, Shahab

    Preservation of the cavernous nerves during prostate cancer surgery is critical in preserving a man's ability to have spontaneous erections following surgery. These microscopic nerves course along the surface of the prostate within a few millimeters of the prostate capsule, and they vary in size and location from one patient to another, making preservation of the nerves difficult during dissection and removal of a cancerous prostate gland. These observations may explain in part the wide variability in reported sexual potency rates (9--86%) following prostate cancer surgery. Any technology capable of providing improved identification, imaging, and visualization of the cavernous nerves during prostate cancer surgery would be of great assistance in improving sexual function after surgery, and result in direct patient benefit. Optical coherence tomography (OCT) is a noninvasive optical imaging technique capable of performing high-resolution cross-sectional in vivo and in situ imaging of microstructures in biological tissues. OCT imaging of the cavernous nerves in the rat and human prostate has recently been demonstrated. However, improvements in the OCT system and the quality of the images for identification of the cavernous nerves is necessary before clinical use. The following chapters describe complementary approaches to improving identification and imaging of the cavernous nerves during OCT of the prostate gland. After the introduction to OCT imaging of the prostate gland, the optimal wavelength for deep imaging of the prostate is studied in Chapter 2. An oblique-incidence single point measurement technique using a normal-detector scanning system was implemented to determine the absorption and reduced scattering coefficients, mua and m's , of fresh canine prostate tissue, ex vivo, from the diffuse reflectance profile of near-IR light as a function of source-detector distance. The effective attenuation coefficient, mueff, and the Optical Penetration Depth (OPD) were

  1. Coherent optical transitions in implanted nitrogen vacancy centers.

    Science.gov (United States)

    Chu, Y; de Leon, N P; Shields, B J; Hausmann, B; Evans, R; Togan, E; Burek, M J; Markham, M; Stacey, A; Zibrov, A S; Yacoby, A; Twitchen, D J; Loncar, M; Park, H; Maletinsky, P; Lukin, M D

    2014-01-01

    We report the observation of stable optical transitions in nitrogen-vacancy (NV) centers created by ion implantation. Using a combination of high temperature annealing and subsequent surface treatment, we reproducibly create NV centers with zero-phonon lines (ZPL) exhibiting spectral diffusion that is close to the lifetime-limited optical line width. The residual spectral diffusion is further reduced by using resonant optical pumping to maintain the NV(-) charge state. This approach allows for placement of NV centers with excellent optical coherence in a well-defined device layer, which is a crucial step in the development of diamond-based devices for quantum optics, nanophotonics, and quantum information science.

  2. Coherent feedback control of multipartite quantum entanglement for optical fields

    Energy Technology Data Exchange (ETDEWEB)

    Yan, Zhihui; Jia, Xiaojun; Xie, Changde; Peng, Kunchi [State Key Laboratory of Quantum Optics and Quantum Optics Devices, Institute of Opto-Electronics, Shanxi University, Taiyuan, 030006 (China)

    2011-12-15

    Coherent feedback control (CFC) of multipartite optical entangled states produced by a nondegenerate optical parametric amplifier is theoretically studied. The features of the quantum correlations of amplitude and phase quadratures among more than two entangled optical modes can be controlled by tuning the transmissivity of the optical beam splitter in the CFC loop. The physical conditions to enhance continuous variable multipartite entanglement of optical fields utilizing the CFC loop are obtained. The numeric calculations based on feasible physical parameters of realistic systems provide direct references for the design of experimental devices.

  3. Demonstration of coherent emission from high-$\\beta$ photonic crystal nanolasers at room temperature

    CERN Document Server

    Hostein, Richard; Gratiet, Luc Le; Talneau, Anne; Beaudoin, Gregoire; Robert-Philip, Isabelle; Sagnes, Isabelle; Beveratos, Alexios

    2010-01-01

    We report on lasing at room temperature and at telecommunications wavelength from photonic crystal nanocavities based on InAsP/InP quantum dots. Such laser cavities with a small modal volume and high quality factor display a high spontaneous emission coupling factor beta. Lasing is confirmed by measuring the second order autocorrelation function. A smooth transition from chaotic to coherent emission is observed, and coherent emission is obtained at 8 times the threshold power.

  4. Demonstration of coherent emission from high-beta photonic crystal nanolasers at room temperature.

    Science.gov (United States)

    Hostein, R; Braive, R; Le Gratiet, L; Talneau, A; Beaudoin, G; Robert-Philip, I; Sagnes, I; Beveratos, A

    2010-04-15

    We report on lasing at room temperature and at telecommunications wavelength from photonic crystal nanocavities based on InAsP/InP quantum dots. Such laser cavities with a small modal volume and high quality factor display a high spontaneous emission coupling factor (beta). Lasing is confirmed by measuring the second-order autocorrelation function. A smooth transition from chaotic to coherent emission is observed, and coherent emission is obtained at eight times the threshold power.

  5. Information Optics and Photonics Algorithms, Systems, and Applications

    CERN Document Server

    Javidi, Bahram

    2010-01-01

    This book addresses applications, recent advances, and emerging areas in fields with applications in information optics and photonics systems. The objective of this book is to illustrate and discuss novel approaches, analytical techniques, models, and technologies that enhance sensing, measurement, processing, interpretation, and visualization of information using free space optics and photonics. The material in this book concentrates on integration of diverse fields for cross-disciplinary applications including bio-photonics, digitally enhanced sensing and imaging systems, multi-dimensional optical imaging and image processing, bio-inspired imaging, 3D visualization, 3D displays, imaging on the nano-scale, quantum optics, super resolution imaging, photonics for biological applications, and holographic information systems. As a result, this book is a useful resource for researchers, engineers, and graduate students who work in the diverse fields comprising information optics and photonics.

  6. The Coherent Photon Scattering Background in Sub-GeV/$c^2$ Direct Dark Matter Searches

    Energy Technology Data Exchange (ETDEWEB)

    Robinson, Alan E. [Fermilab

    2016-10-24

    Proposed dark matter detectors with eV-scale sensitivities will detect a large background of atomic (nuclear) recoils from coherent photon scattering. This background climbs steeply below $\\sim10$~eVnr, far exceeding the declining rate of low-energy Compton recoils. The upcoming generation of dark matter detectors will not be limited by this background, but further development of eV-scale and sub-eV detectors will require the use of low-$Z$ target materials, such as helium, to avoid a large rate of coherent photon scattering.

  7. The coherent photon scattering background in sub-GeV/$c^2$ direct dark matter searches

    CERN Document Server

    Robinson, Alan E

    2016-01-01

    Proposed dark matter detectors with eV-scale sensitivities will detect a large background of atomic (nuclear) recoils from coherent photon scattering. This background climbs steeply below $\\sim10$~eVnr, far exceeding the declining rate of low-energy Compton recoils. The upcoming generation of dark matter detectors will not be limited by this background, but further development of eV-scale and sub-eV detectors will require the use of low-$Z$ target materials, such as helium, to avoid a large rate of coherent photon scattering.

  8. Cavity-photon-switched coherent transient transport in a double quantum waveguide

    Energy Technology Data Exchange (ETDEWEB)

    Abdullah, Nzar Rauf, E-mail: nra1@hi.is; Gudmundsson, Vidar, E-mail: vidar@raunvis.hi.is [Science Institute, University of Iceland, Dunhaga 3, IS-107 Reykjavik (Iceland); Tang, Chi-Shung [Department of Mechanical Engineering, National United University, 1, Lienda, 36003 Miaoli, Taiwan (China); Manolescu, Andrei [School of Science and Engineering, Reykjavik University, Menntavegur 1, IS-101 Reykjavik (Iceland)

    2014-12-21

    We study a cavity-photon-switched coherent electron transport in a symmetric double quantum waveguide. The waveguide system is weakly connected to two electron reservoirs, but strongly coupled to a single quantized photon cavity mode. A coupling window is placed between the waveguides to allow electron interference or inter-waveguide transport. The transient electron transport in the system is investigated using a quantum master equation. We present a cavity-photon tunable semiconductor quantum waveguide implementation of an inverter quantum gate, in which the output of the waveguide system may be selected via the selection of an appropriate photon number or “photon frequency” of the cavity. In addition, the importance of the photon polarization in the cavity, that is, either parallel or perpendicular to the direction of electron propagation in the waveguide system is demonstrated.

  9. The Development, Commercialization, and Impact of Optical Coherence Tomography.

    Science.gov (United States)

    Fujimoto, James; Swanson, Eric

    2016-07-01

    This review was written for the special issue of IOVS to describe the history of optical coherence tomography (OCT) and its evolution from a nonscientific, historic perspective. Optical coherence tomography has become a standard of care in ophthalmology, providing real-time information on structure and function - diagnosing disease, evaluating progression, and assessing response to therapy, as well as helping to understand disease pathogenesis and create new therapies. Optical coherence tomography also has applications in multiple clinical specialties, fundamental research, and manufacturing. We review the early history of OCT describing how research and development evolves and the important role of multidisciplinary collaboration and expertise. Optical coherence tomography had its origin in femtosecond optics, but used optical communications technologies and required advanced engineering for early OCT prototypes, clinical feasibility studies, entrepreneurship, and corporate development in order to achieve clinical acceptance and clinical impact. Critical advances were made by early career researchers, clinician scientists, engineering experts, and business leaders, which enabled OCT to have a worldwide impact on health care. We introduce the concept of an "ecosystem" consisting of research, government funding, collaboration and competition, clinical studies, innovation, entrepreneurship and industry, and impact - all of which must work synergistically. The process that we recount is long and challenging, but it is our hope that it might inspire early career professionals in science, engineering, and medicine, and that the clinical and research community will find this review of interest.

  10. Coherent Dynamics of Quantum Dots in Photonic-Crystal Cavities

    DEFF Research Database (Denmark)

    Madsen, Kristian Høeg

    deviations. Similar measurements on a quantum dot in a photonic-crystal cavity sow a Rabi splitting on resonance, while time-resolved measurements prove that the system is in the weak coupling regime. Whle tuning the quantum dot through resonance of the high-Q mode we observe a strong and surprisingly...... Successfully model the decay rates with a microscopic model that allows us to for the first time extract the effective phonon density of states, which we can model with bulk phonons. Studies on a quantum dot detuned from a low-Q mode of a photonic-crystal cavity show a high collection efficiency at the first......In this thesis we have performed quantum-electrodynamics experiments on quantum dots embedded in photonic-crystal cavities. We perform a quantitative comparison of the decay dynamics and emission spectra of quantum dots embedded in a micropillar cavity and a photonic-crystal cavity. The light...

  11. Generation and Photonic Guidance of Multi-Octave Optical-Frequency Combs

    DEFF Research Database (Denmark)

    Couny, F.; Benabid, F.; Roberts, John;

    2007-01-01

    crystal fiber. The waveguidance results not from a photonic band gap but from the inhibited coupling between the core and cladding modes. The spectrum consists of up to 45 high-order Stokes and anti-Stokes lines and is generated by driving the confined gas with a single, moderately powerful (10-kilowatt......Ultrabroad coherent comb-like optical spectra spanning several octaves are a chief ingredient in the emerging field of attoscience. We demonstrate generation and guidance of a three-octave spectral comb, spanning wavelengths from 325 to 2300 nanometers, in a hydrogen-filled hollow-core photonic...

  12. Optical wave propagation in photonic crystal metamaterials

    Science.gov (United States)

    Khan, Kaisar; Mnaymneh, Khaled; Awad, Hazem; Hasan, Imad; Hall, Trevor

    2014-09-01

    Metamaterials that provide negative refraction can be implemented in photonic crystals (PhCs) through careful design of the devices. Theoretically, we demonstrate that the dispersion can be altered to achieve negative refraction. This can be done through engineering the geometry of the device as well as selecting appropriate materials. The PhC also demonstrates slow light that facilitate sensing chemicals or biological agents. Using metallic materials such as gold nano-particle enables PhCs to guide optical waves in desired pathways. Also using magnetic materials such as highly doped n-GaAs, we can tune the band gap by changing magnetic field. The simulated results are consistent with some of the previously reported experimental results and give us guidance for future experiments.

  13. Photonics

    CERN Document Server

    Andrews, David L

    2015-01-01

    Discusses the basic physical principles underlying the technology instrumentation of photonics This volume discusses photonics technology and instrumentation. The topics discussed in this volume are: Communication Networks; Data Buffers; Defense and Security Applications; Detectors; Fiber Optics and Amplifiers; Green Photonics; Instrumentation and Metrology; Interferometers; Light-Harvesting Materials; Logic Devices; Optical Communications; Remote Sensing; Solar Energy; Solid-State Lighting; Wavelength Conversion Comprehensive and accessible coverage of the whole of modern photonics Emphas

  14. Photonics

    CERN Document Server

    Andrews, David L

    2015-01-01

    Discusses the basic physical principles underlying Biomedical Photonics, spectroscopy and microscopy This volume discusses biomedical photonics, spectroscopy and microscopy, the basic physical principles underlying the technology and its applications. The topics discussed in this volume are: Biophotonics; Fluorescence and Phosphorescence; Medical Photonics; Microscopy; Nonlinear Optics; Ophthalmic Technology; Optical Tomography; Optofluidics; Photodynamic Therapy; Image Processing; Imaging Systems; Sensors; Single Molecule Detection; Futurology in Photonics. Comprehensive and accessible cov

  15. Efficient out-coupling of high-purity single photons from a coherent quantum dot in a photonic-crystal cavity

    CERN Document Server

    Madsen, K H; Liu, J; Javadi, A; Albrecht, S M; Yeo, I; Stobbe, S; Lodahl, P

    2014-01-01

    We demonstrate a single-photon collection efficiency of $(44.3\\pm2.1)\\%$ from a quantum dot in a low-Q mode of a photonic-crystal cavity with a single-photon purity of $g^{(2)}(0)=(4\\pm5)\\%$ and directly detect up to $962\\pm46$ kilocounts per second on a single-photon detector. The high collection efficiency is found to be broadband, as is confirmed by detailed numerical simulations. Cavity-enhanced efficient excitation of quantum dots is obtained through phonon-mediated excitation and under these conditions, single-photon indistinguishability measurements reveal long coherence times of up to $0.77\\pm0.19$ ns. Our work demonstrates that photonic crystals provide a very promising platform for highly integrated generation of coherent single photons including the efficient outcoupling of the photons from the photonic chip.

  16. A photon-photon quantum gate based on a single atom in an optical resonator.

    Science.gov (United States)

    Hacker, Bastian; Welte, Stephan; Rempe, Gerhard; Ritter, Stephan

    2016-08-11

    That two photons pass each other undisturbed in free space is ideal for the faithful transmission of information, but prohibits an interaction between the photons. Such an interaction is, however, required for a plethora of applications in optical quantum information processing. The long-standing challenge here is to realize a deterministic photon-photon gate, that is, a mutually controlled logic operation on the quantum states of the photons. This requires an interaction so strong that each of the two photons can shift the other's phase by π radians. For polarization qubits, this amounts to the conditional flipping of one photon's polarization to an orthogonal state. So far, only probabilistic gates based on linear optics and photon detectors have been realized, because "no known or foreseen material has an optical nonlinearity strong enough to implement this conditional phase shift''. Meanwhile, tremendous progress in the development of quantum-nonlinear systems has opened up new possibilities for single-photon experiments. Platforms range from Rydberg blockade in atomic ensembles to single-atom cavity quantum electrodynamics. Applications such as single-photon switches and transistors, two-photon gateways, nondestructive photon detectors, photon routers and nonlinear phase shifters have been demonstrated, but none of them with the ideal information carriers: optical qubits in discriminable modes. Here we use the strong light-matter coupling provided by a single atom in a high-finesse optical resonator to realize the Duan-Kimble protocol of a universal controlled phase flip (π phase shift) photon-photon quantum gate. We achieve an average gate fidelity of (76.2 ± 3.6) per cent and specifically demonstrate the capability of conditional polarization flipping as well as entanglement generation between independent input photons. This photon-photon quantum gate is a universal quantum logic element, and therefore could perform most existing two-photon operations

  17. High-resolution second harmonic optical coherence tomography

    Science.gov (United States)

    Jiang, Yi; Tomov, Ivan V.; Wang, Yimin; Chen, Zhongping

    2005-04-01

    A high-resolution Second Harmonic Optical Coherence Tomography (SH-OCT) system is demonstrated using a spectrum broadened femtosecond Ti:sapphire laser. An axial resolution of 4.2 μm at the second harmonic wave center wavelength of 400 nm has been achieved. Because the SH-OCT system uses the second harmonic generation signals that strongly depend on the orientation, polarization and local symmetry properties of chiral molecules, this technique provides unique contrast enhancement to conventional optical coherence tomography. The system is applied to image biological tissues like the rat-tail tendon. Images of highly organized collagen fibrils in the rat-tail tendon have been demonstrated.

  18. Two-photon interference and coherent control of single InAs quantum dot emissions in an Ag-embedded structure

    Energy Technology Data Exchange (ETDEWEB)

    Liu, X., E-mail: iu.xiangming@nims.go.jp [Research Institute for Electronic Science, Hokkaido University, Sapporo 001-0021 (Japan); National Institute for Materials Science, 1-1 Namiki, Tsukuba 305-0044 (Japan); Kumano, H.; Nakajima, H.; Odashima, S.; Asano, T.; Suemune, I. [Research Institute for Electronic Science, Hokkaido University, Sapporo 001-0021 (Japan); Kuroda, T. [National Institute for Materials Science, 1-1 Namiki, Tsukuba 305-0044 (Japan)

    2014-07-28

    We have recently reported the successful fabrication of bright single-photon sources based on Ag-embedded nanocone structures that incorporate InAs quantum dots. The source had a photon collection efficiency as high as 24.6%. Here, we show the results of various types of photonic characterizations of the Ag-embedded nanocone structures that confirm their versatility as regards a broad range of quantum optical applications. We measure the first-order autocorrelation function to evaluate the coherence time of emitted photons, and the second-order correlation function, which reveals the strong suppression of multiple photon generation. The high indistinguishability of emitted photons is shown by the Hong-Ou-Mandel-type two-photon interference. With quasi-resonant excitation, coherent population flopping is demonstrated through Rabi oscillations. Extremely high single-photon purity with a g{sup (2)}(0) value of 0.008 is achieved with π-pulse quasi-resonant excitation.

  19. [Applications of optical coherence tomography (OCT) in neuro-ophthalmology].

    Science.gov (United States)

    Kernstock, C; Friebe, K; Tonagel, F

    2013-11-01

    Optical coherence tomography (OCT) has revolutionised ophthalmology. Due to modern instruments with extremely high resolution there are more and more applications also in neuro-ophthalmological disorders. This review gives an overview on typical changes in OCT for the following diseases: autosomal dominant optic atrophy, Leber hereditary optic neuropathy, toxic, traumatic and compressive optic neuropathy, optic nerve drusen, anterior ischaemic optic neuropathy, optic disc pit, papilledema, optic neuritis (isolated or associated with multiple sclerosis or neuromyelitis optica), neurodegenerative diseases and hereditary retinal diseases. A diagnosis exclusively based on an OCT examination is not always possible, but in several diseases there are pathognomonic changes that directly lead to the correct diagnosis. Particularly with the often complex settings in neuro-ophtalmology the OCT should be seen as a supplementary modality and not as a replacement for other techniques.

  20. A photon-photon quantum gate based on a single atom in an optical resonator

    Science.gov (United States)

    Hacker, Bastian; Welte, Stephan; Rempe, Gerhard; Ritter, Stephan

    2016-08-01

    That two photons pass each other undisturbed in free space is ideal for the faithful transmission of information, but prohibits an interaction between the photons. Such an interaction is, however, required for a plethora of applications in optical quantum information processing. The long-standing challenge here is to realize a deterministic photon-photon gate, that is, a mutually controlled logic operation on the quantum states of the photons. This requires an interaction so strong that each of the two photons can shift the other’s phase by π radians. For polarization qubits, this amounts to the conditional flipping of one photon’s polarization to an orthogonal state. So far, only probabilistic gates based on linear optics and photon detectors have been realized, because “no known or foreseen material has an optical nonlinearity strong enough to implement this conditional phase shift”. Meanwhile, tremendous progress in the development of quantum-nonlinear systems has opened up new possibilities for single-photon experiments. Platforms range from Rydberg blockade in atomic ensembles to single-atom cavity quantum electrodynamics. Applications such as single-photon switches and transistors, two-photon gateways, nondestructive photon detectors, photon routers and nonlinear phase shifters have been demonstrated, but none of them with the ideal information carriers: optical qubits in discriminable modes. Here we use the strong light-matter coupling provided by a single atom in a high-finesse optical resonator to realize the Duan-Kimble protocol of a universal controlled phase flip (π phase shift) photon-photon quantum gate. We achieve an average gate fidelity of (76.2 ± 3.6) per cent and specifically demonstrate the capability of conditional polarization flipping as well as entanglement generation between independent input photons. This photon-photon quantum gate is a universal quantum logic element, and therefore could perform most existing two-photon

  1. Quantum Optics with Photonic Nanowires and Photonic Trumpets: Basics and Applications

    DEFF Research Database (Denmark)

    Gerard, J.; Claudon, J.; Munsch, M.

    Optimizing the coupling between a localized quantum emitter and a single-mode optical channel represents a powerful route to realise bright sources of non-classical light states. Reversibly, the e±cient absorption of a photon impinging on the emitter is key to realise a spin-photon interface......, the node of future quantum networks. Besides optical microcavities [1], photonic wires have recently demonstrated in this context an appealing potential [2, 3]. For instance, single photon sources (SPS) based on a single quantum dot in a vertical photonic wire with integrated bottom mirror and tapered tip...... have enabled for the ¯rst time to achieve simultaneously a very high e±ciency (0.72 photon per pulse) and a very pure single photon emission (g(2)(0)

  2. Electrophysiological and Anatomical Correlates of Spinal Cord Optical Coherence Tomography.

    Directory of Open Access Journals (Sweden)

    Mario E Giardini

    Full Text Available Despite the continuous improvement in medical imaging technology, visualizing the spinal cord poses severe problems due to structural or incidental causes, such as small access space and motion artifacts. In addition, positional guidance on the spinal cord is not commonly available during surgery, with the exception of neuronavigation techniques based on static pre-surgical data and of radiation-based methods, such as fluoroscopy. A fast, bedside, intraoperative real-time imaging, particularly necessary during the positioning of endoscopic probes or tools, is an unsolved issue. The objective of our work, performed on experimental rats, is to demonstrate potential intraoperative spinal cord imaging and probe guidance by optical coherence tomography (OCT. Concurrently, we aimed to demonstrate that the electromagnetic OCT irradiation exerted no particular effect at the neuronal and synaptic levels. OCT is a user-friendly, low-cost and endoscopy-compatible photonics-based imaging technique. In particular, by using a Fourier-domain OCT imager, operating at 850 nm wavelength and scanning transversally with respect to the spinal cord, we have been able to: 1 accurately image tissue structures in an animal model (muscle, spine bone, cerebro-spinal fluid, dura mater and spinal cord, and 2 identify the position of a recording microelectrode approaching and inserting into the cord tissue 3 check that the infrared radiation has no actual effect on the electrophysiological activity of spinal neurons. The technique, potentially extendable to full three-dimensional image reconstruction, shows prospective further application not only in endoscopic intraoperative analyses and for probe insertion guidance, but also in emergency and adverse situations (e.g. after trauma for damage recognition, diagnosis and fast image-guided intervention.

  3. Coherent properties of single quantum dot transitions and single photon emission

    Energy Technology Data Exchange (ETDEWEB)

    Ester, Patrick

    2008-04-23

    In this work, the properties and the different dephasing mechanisms of single QD transitions are analyzed. In addition, some applications are presented which arise due to the properties of the confined exciton. The isolation of a single QD out of the ensemble is achieved via near field shadow masks, which restricts excitation and QD luminescence to a single QD. The integration of a QD-layer into a diode structure allows for an analysis of various dephasing mechanisms of a confined electron hole pair. The single QD is characterized regarding the energy of nearly all possible transitions, e.g. the ground state, excited states, charged states, multiple occupations, and phonon assisted absorptions. A very important issue in this content is the voltage dependence of the transition energy and thereby the ability of tunneling processes of charge carriers in and out of the QD. The QD-states, which are subject of investigation here, are the single exciton ground state, the first excited state (p-shell), and the (GaAs-) LO (longitudinal optical) phonon assisted absorption. By applying a suitable voltage, the resonantly excited ground state exciton is able to decay by a tunneling process, which reflects the transition energy in the photocurrent spectra. The p-shell transition decays by a relaxation process into the ground state, followed by an optical recombination process. The phonon assisted absorption differs from the p-shell transition. The resonant excitation energy fits to the exciton ground state energy plus the energy of a GaAs LO phonon. In this case, the single exciton (ground state) is generated as well as a GaAs LO phonon. These three states are investigated in different respects, such as different applied voltages, excitation polarizations, excitation intensities, and coherent properties. The LO-assisted absorption shows also a saturation behavior. The exciton in the QD is able to interfere with the second laser pulse due to the storage of the phase information

  4. Quantum noise in large-scale coherent nonlinear photonic circuits

    CERN Document Server

    Santori, Charles; Beausoleil, Raymond G; Tezak, Nikolas; Hamerly, Ryan; Mabuchi, Hideo

    2014-01-01

    A semiclassical simulation approach is presented for studying quantum noise in large-scale photonic circuits incorporating an ideal Kerr nonlinearity. A netlist-based circuit solver is used to generate matrices defining a set of stochastic differential equations, in which the resonator field variables represent random samplings of the Wigner quasi-probability distributions. Although the semiclassical approach involves making a large-photon-number approximation, tests on one- and two-resonator circuits indicate satisfactory agreement between the semiclassical and full-quantum simulation results in the parameter regime of interest. The semiclassical model is used to simulate random errors in a large-scale circuit that contains 88 resonators and hundreds of components in total, and functions as a 4-bit ripple counter. The error rate as a function of on-state photon number is examined, and it is observed that the quantum fluctuation amplitudes do not increase as signals propagate through the circuit, an important...

  5. Optical limiter based on two-dimensional nonlinear photonic crystals

    Science.gov (United States)

    Belabbas, Amirouche; Lazoul, Mohamed

    2016-04-01

    The aim behind this work is to investigate the capabilities of nonlinear photonic crystals to achieve ultra-fast optical limiters based on third order nonlinear effects. The purpose is to combine the actions of nonlinear effects with the properties of photonic crystals in order to activate the photonic band according to the magnitude of the nonlinear effects, themselves a function of incident laser power. We are interested in designing an optical limiter based nonlinear photonic crystal operating around 1064 nm and its second harmonic at 532 nm. Indeed, a very powerful solid-state laser that can blind or destroy optical sensors and is widely available and easy to handle. In this work, we perform design and optimization by numerical simulations to determine the better structure for the nonlinear photonic crystal to achieve compact and efficient integrated optical limiter. The approach consists to analyze the band structures in Kerr-nonlinear two-dimensional photonic crystals as a function of the optical intensity. We confirm that these bands are dynamically red-shifted with regard to the bands observed in linear photonic crystals or in the case of weak nonlinear effects. The implemented approach will help to understand such phenomena as intensitydriven optical limiting with Kerr-nonlinear photonic crystals.

  6. Recent advances in liquid-crystal fiber optics and photonics

    Science.gov (United States)

    Woliński, T. R.; Siarkowska, A.; Budaszewski, D.; Chychłowski, M.; Czapla, A.; Ertman, S.; Lesiak, P.; Rutkowska, K. A.; Orzechowski, K.; Sala-Tefelska, M.; Sierakowski, M.; DÄ browski, R.; Bartosewicz, B.; Jankiewicz, B.; Nowinowski-Kruszelnicki, E.; Mergo, P.

    2017-02-01

    Liquid crystals over the last two decades have been successfully used to infiltrate fiber-optic and photonic structures initially including hollow-core fibers and recently micro-structured photonic crystal fibers (PCFs). As a result photonic liquid crystal fibers (PLCFs) have been created as a new type of micro-structured fibers that benefit from a merge of "passive" PCF host structures with "active" LC guest materials and are responsible for diversity of new and uncommon spectral, propagation, and polarization properties. This combination has simultaneously boosted research activities in both fields of Liquid Crystals Photonics and Fiber Optics by demonstrating that optical fibers can be more "special" than previously thought. Simultaneously, photonic liquid crystal fibers create a new class of fiber-optic devices that utilize unique properties of the photonic crystal fibers and tunable properties of LCs. Compared to "classical" photonic crystal fibers, PLCFs can demonstrate greatly improved control over their optical properties. The paper discusses the latest advances in this field comprising PLCFs that are based on nanoparticles-doped LCs. Doping of LCs with nanoparticles has recently become a common method of improving their optical, magnetic, electrical, and physical properties. Such a combination of nanoparticles-based liquid crystals and photonic crystal fibers can be considered as a next milestone in developing a new class of fiber-based optofluidic systems.

  7. Coherent destruction of tunneling in two-level system driven across avoided crossing via photon statistics.

    Science.gov (United States)

    Miao, Qiang; Zheng, Yujun

    2016-06-29

    In this paper, the nature of the multi-order resonance and coherent destruction of tunneling (CDT) for two-level system driven cross avoided crossing is investigated by employing the emitted photons 〈N〉 and the Mandel's Q parameter based on the photon counting statistics. An asymmetric feature of CDT is shown in the spectrum of Mandel's Q parameter. Also, the CDT can be employed to suppress the spontaneous decay and prolong waiting time noticeably. The photon emission pattern is of monotonicity in strong relaxation, and homogeneity in pure dephasing regime, respectively.

  8. Coherent destruction of tunneling in two-level system driven across avoided crossing via photon statistics

    Science.gov (United States)

    Miao, Qiang; Zheng, Yujun

    2016-06-01

    In this paper, the nature of the multi-order resonance and coherent destruction of tunneling (CDT) for two-level system driven cross avoided crossing is investigated by employing the emitted photons and the Mandel’s Q parameter based on the photon counting statistics. An asymmetric feature of CDT is shown in the spectrum of Mandel’s Q parameter. Also, the CDT can be employed to suppress the spontaneous decay and prolong waiting time noticeably. The photon emission pattern is of monotonicity in strong relaxation, and homogeneity in pure dephasing regime, respectively.

  9. Dicke Coherent Narrowing in Two-Photon and Raman Spectroscopy of Thin Vapour Cells

    CERN Document Server

    Dutier, G; Hamdi, I; Maurin, I; Saltiel, S; Bloch, D; Ducloy, M; Dutier, Gabriel; Todorov, Petko; Hamdi, Ismah\\`{e}ne; Maurin, Isabelle; Saltiel, Solomon; Bloch, Daniel; Ducloy, Martial

    2005-01-01

    The principle of coherent Dicke narrowing in a thin vapour cell, in which sub-Doppler spectral lineshapes are observed under a normal irradiation for a l/2 thickness, is generalized to two-photon spectroscopy. Only the sum of the two wave vectors must be normal to the cell, making the two-photon scheme highly versatile. A comparison is provided between the Dicke narrowing with copropagating fields, and the residual Doppler-broadening occurring with counterpropagating geometries. The experimental feasibility is discussed on the basis of a first observation of a two-photon resonance in a 300 nm-thick Cs cell. Extension to the Raman situation is finally considered.

  10. Investigation of optical currents in coherent and partially coherent vector fields

    DEFF Research Database (Denmark)

    Angelsky, O. V.; Gorsky, M. P.; Maksimyak, P. P.

    2011-01-01

    in the arrangements of two-wave and four-wave superposition on the characteris-tics of the microparticle’s motion has been analyzed. The prospects of stud-ying temporal coherence using the proposed approach are made. For the first time, the possibility of diagnostics of optical currents in liquids caused...

  11. Microcontrollers and optical sensors for education in optics and photonics

    Science.gov (United States)

    Dressler, Paul; Wielage, Heinz; Haiss, Ulrich; Vauderwange, Oliver; Wozniak, P.; Curticapean, Dan

    2014-09-01

    The digital revolution is going full steam ahead, with a constantly growing number of new devices providing a steady increase in complexity and power. Most of the success is based on one important invention: the microprocessor/microcontroller. In this paper the authors present how to integrate microcontrollers and optical sensors in the curricula of media engineering by combining subjects of media technology, optics, information technology and media design. Hereby the aim is not to teach these topics separate from each other, but to bring them together in interdisciplinary lectures, projects and applications. Microcontrollers can be applied in various ways to teach content from the fields of optics and photonics. They can be used to control LEDs, displays, light detectors and infrared sensors, which makes it possible to build measuring instruments like e.g. a lux meter, a light barrier or an optical distance meter. The learning goals are to stimulate the student's interest in the multiplicity of subjects related to this course and to support a deeper understanding of the close connections between them. The teaching method that the authors describe in their paper turned out to be very successful, as the participants are motivated to bring in their own ideas for projects, they spend more time than requested and as many students return to the courses as tutors. It is an example for effectual knowledge transfer and exchange of ideas among students.

  12. Storage and control of optical photons using Rydberg polaritons.

    Science.gov (United States)

    Maxwell, D; Szwer, D J; Paredes-Barato, D; Busche, H; Pritchard, J D; Gauguet, A; Weatherill, K J; Jones, M P A; Adams, C S

    2013-03-08

    We use a microwave field to control the quantum state of optical photons stored in a cold atomic cloud. The photons are stored in highly excited collective states (Rydberg polaritons) enabling both fast qubit rotations and control of photon-photon interactions. Through the collective read-out of these pseudospin rotations it is shown that the microwave field modifies the long-range interactions between polaritons. This technique provides a powerful interface between the microwave and optical domains, with applications in quantum simulations of spin liquids, quantum metrology and quantum networks.

  13. Optical Realization of Deterministic Entanglement Concentration of Polarized Photons

    Institute of Scientific and Technical Information of China (English)

    GU Yong-Jian; XIAN Liang; LI Wen-Dong; MA Li-Zhen

    2008-01-01

    @@ We propose a scheme for optical realization of deterministic entanglement concentration of polarized photons.To overcome the difficulty due to the lack of sufficiently strong interactions between photons, teleportation is employed to transfer the polarization states of two photons onto the path and polarization states of a third photon, which is made possible by the recent experimental realization of the deterministic and complete Bell state measurement. Then the required positive operator-valued measurement and further operations can be implemented deterministically by using a linear optical setup. All these are within the reach of current technology.

  14. Photon counts modulation in optical time domain reflectometry

    Institute of Scientific and Technical Information of China (English)

    Wang Xiao-Bo; Wang Jing-Jing; Zhang Guo-Feng; Xiao Lian-Tuan; Jia Suo-Tang

    2011-01-01

    The quantum fluctuation of photon counting limits the field application of optical time domain reflection. A method of photon counts modulation optics time domain reflection with single photon detection at 1.55 un is presented. The influence of quantum fluctuation can be effectively controlled by demodulation technology since quantum fluctuation shows a uniform distribution in the frequency domain. Combined with the changing of the integration time of the lock-in amplifier, the signal to noise ratio is significantly enhanced. Accordingly the signal to noise improvement ratio reaches 31.7 dB compared with the direct photon counting measurement.

  15. Interconnection of polarization properties and coherence of optical fields.

    Science.gov (United States)

    Zenkova, Claudia Yu

    2014-04-01

    Theoretical and experimental approaches to diagnosing internal spin and orbital optical flows and the corresponding optical forces caused by these flows are offered. These approaches are based on the investigation of the motion of the particles tested in the formed optical field. The dependence of the above-mentioned forces upon the size and optical properties of the particles is demonstrated. The possibility of using kinematic values defining the motion dynamics of particles of the Rayleigh light scattering mechanism to make a quantitative assessment of the degree of coherence of mutually orthogonal waves that are linearly polarized in the incidence plane is demonstrated. The feasibility of using the above mentioned approach, its shortcomings, and its advantages over the interfering method for estimating the degree of coherence are analyzed.

  16. Analog signal processing for optical coherence imaging systems

    Science.gov (United States)

    Xu, Wei

    Optical coherence tomography (OCT) and optical coherence microscopy (OCM) are non-invasive optical coherence imaging techniques, which enable micron-scale resolution, depth resolved imaging capability. Both OCT and OCM are based on Michelson interferometer theory. They are widely used in ophthalmology, gastroenterology and dermatology, because of their high resolution, safety and low cost. OCT creates cross sectional images whereas OCM obtains en face images. In this dissertation, the design and development of three increasingly complicated analog signal processing (ASP) solutions for optical coherence imaging are presented. The first ASP solution was implemented for a time domain OCT system with a Rapid Scanning Optical Delay line (RSOD)-based optical signal modulation and logarithmic amplifier (Log amp) based demodulation. This OCT system can acquire up to 1600 A-scans per second. The measured dynamic range is 106dB at 200A-scan per second. This OCT signal processing electronics includes an off-the-shelf filter box with a Log amp circuit implemented on a PCB board. The second ASP solution was developed for an OCM system with synchronized modulation and demodulation and compensation for interferometer phase drift. This OCM acquired micron-scale resolution, high dynamic range images at acquisition speeds up to 45,000 pixels/second. This OCM ASP solution is fully custom designed on a perforated circuit board. The third ASP solution was implemented on a single 2.2 mm x 2.2 mm complementary metal oxide semiconductor (CMOS) chip. This design is expandable to a multiple channel OCT system. A single on-chip CMOS photodetector and ASP channel was used for coherent demodulation in a time domain OCT system. Cross-sectional images were acquired with a dynamic range of 76dB (limited by photodetector responsivity). When incorporated with a bump-bonded InGaAs photodiode with higher responsivity, the expected dynamic range is close to 100dB.

  17. Demonstration of Coherent-State Discrimination Using a Displacement-Controlled Photon-Number-Resolving Detector

    DEFF Research Database (Denmark)

    Wittmann, C.; Andersen, Ulrik Lund; Takeoka, M.

    2010-01-01

    We experimentally demonstrate a new measurement scheme for the discrimination of two coherent states. The measurement scheme is based on a displacement operation followed by a photon-number-resolving detector, and we show that it outperforms the standard homodyne detector which we, in addition...

  18. Coherent anti-Stokes Raman scattering microscopy with a photonic crystal fiber based light source

    DEFF Research Database (Denmark)

    Paulsen, H.N.; Hilligsøe, Karen Marie; Thøgersen, J.

    2003-01-01

    A coherent anti-Stokes Raman scattering microscope based on a Ti:sapphire femtosecond oscillator and a photonic crystal fiber is demonstrated. The nonlinear response of the fiber is used to generate the additional wavelength needed in the Raman process. The applicability of the setup is demonstra...... is demonstrated by imaging of micrometer-sized polystyrene beads....

  19. Path length distribution of multiple-scattered photons by low coherence Doppler interferometry

    NARCIS (Netherlands)

    Petoukhova, Anna; Steenbergen, Wiendelt; de Mul, F.F.M.; Tuchin, V.V.; Izatt, J.A.; Fujimoto, J.G.

    2002-01-01

    We report results of measurements by low coherence Doppler interferometry of the path length distribution of photons undergoing multiple scattering in a highly turbid medium. We use a Mach-Zehnder interferometer with multimode graded index fibers and a superluminescent diode as light source. The pat

  20. Broadband multiplex coherent anti-Stokes Raman scattering microscopy employing photonic-crystal fibers

    DEFF Research Database (Denmark)

    Andresen, Esben Ravn; Paulsen, Henrik Nørgaard; Birkedal, Victoria;

    2006-01-01

    We demonstrate spectral multiplex coherent anti-Stokes Raman scattering (CARS) spectroscopy and microscopy based on a single Ti:sapphire oscillator and a nonlinear photonic-crystal fiber (PCF). The Stokes pulse is generated by spectral conversion of the laser pulse in a PCF. The pump pulse...

  1. Quantum filtering of optical coherent states

    DEFF Research Database (Denmark)

    Wittmann, C.; Elser, D.; Andersen, Ulrik Lund

    2008-01-01

    We propose and experimentally demonstrate nondestructive and noiseless removal (filtering) of vacuum states from an arbitrary set of coherent states of continuous variable systems. Errors, i.e., vacuum states in the quantum information are diagnosed through a weak measurement, and on that basis......, probabilistically filtered out. We consider three different filters based on on-off detection, phase stabilized, and phase randomized homodyne detection. We find that on-off detection, optimal in the ideal theoretical setting, is superior to the homodyne strategy also in a practical setting....

  2. Photon-assisted Landau-Zener transition: Role of coherent superposition states

    CERN Document Server

    Sun, Zhe; Wang, Xiaoguang; Nori, Franco

    2012-01-01

    We investigate a Landau-Zener (LZ) transition process modelled by a quantum two-level system (TLS) coupled to a photon mode when the bias energy is varied linearly in time. The initial state of the photon field is assumed to be a superposition of coherent states, leading to a more intricate LZ transition. Applying the rotating-wave approximation (RWA), analytical results are obtained revealing the enhancement of the LZ probability by increasing the average photon number. We also consider the creation of entanglement and the change of photon statistics during the LZ process. When without the RWA, we find some qualitative differences of the LZ dynamics from the RWA results, e.g., the average photon number no longer monotonically enhances the LZ probability.

  3. Research and development for X-ray optics and diagnostics on the linac coherent light source (LCLS)

    CERN Document Server

    Wootton, A; Barbee, T W; Bionta, R; Jankowski, A; London, R; Ryutov, D; Shepherd, R; Shlyaptsev, V; Tatchyn, R; Toor, A

    2002-01-01

    The Linac Coherent Light Source is a 1.5-15 A-wavelength free-electron laser (FEL), currently proposed for the Stanford Linear Accelerator Center. The photon output consists of high brightness, transversely coherent pulses with duration <300 fs, together with a broad spontaneous spectrum with total power comparable to the coherent output. The output fluence, and pulse duration, pose special challenges for optical component and diagnostic designs. We first discuss the specific requirements for the initial scientific experiments, and our proposed solutions. We then describe the supporting research and development program that includes: experimental and theoretical material damage studies; high-resolution multilayer design, fabrication, and testing; replicated closed-form optics design and manufacturing; BeB manufacturing; and low-Z Fresnel lens design, fabrication and testing. Finally, some novel concepts for optical components are presented.

  4. Slow light enhanced correlated photon pair generation in photonic-crystal coupled-resonator optical waveguides

    CERN Document Server

    Matsuda, Nobuyuki; Shimizu, Kaoru; Tokura, Yasuhiro; Kuramochi, Eiichi; Notomi, Masaya; 10.1364/OE.21.008596

    2013-01-01

    We demonstrate the generation of quantum-correlated photon pairs from a Si photonic-crystal coupled-resonator optical waveguide. A slow-light supermode realized by the collective resonance of high-Q and small-mode-volume photonic-crystal cavities successfully enhanced the efficiency of the spontaneous four-wave mixing process. The generation rate of photon pairs was improved by two orders of magnitude compared with that of a photonic-crystal line defect waveguide without a slow-light effect.

  5. Slow light enhanced correlated photon pair generation in photonic-crystal coupled-resonator optical waveguides.

    Science.gov (United States)

    Matsuda, Nobuyuki; Takesue, Hiroki; Shimizu, Kaoru; Tokura, Yasuhiro; Kuramochi, Eiichi; Notomi, Masaya

    2013-04-08

    We demonstrate the generation of quantum-correlated photon pairs from a Si photonic-crystal coupled-resonator optical waveguide. A slow-light supermode realized by the collective resonance of high-Q and small-mode-volume photonic-crystal cavities successfully enhanced the efficiency of the spontaneous four-wave mixing process. The generation rate of photon pairs was improved by two orders of magnitude compared with that of a photonic-crystal line defect waveguide without a slow-light effect.

  6. Enhancement of Optical Coherence Tomography Axial Resolution by Spectral Shaping

    Institute of Scientific and Technical Information of China (English)

    孙汕; 郭继华; 高湔松; 薛平

    2002-01-01

    We propose a new method of changing the spectrum shape to improve the axial resolution of optical coherencetomography (OCT). Theoretical analysis shows that certain spectral shaping can shorten the coherence length.Comparisons of the simulation and experimental measurements of spectral shape and axial resolution of OCTare given, showing that the axial resolution of OCT is enhanced by a factor of 1.4.

  7. Optical coherent tomography in diagnoses of peripheral retinal degenarations

    Directory of Open Access Journals (Sweden)

    O. G. Pozdeyeva

    2013-01-01

    Full Text Available Purpose: Studying the capabilities of optical coherence tomography (RTVue-100, OPTOVUE, USA in evaluation of peripheral retinal degenerations, vitreoretinal adhesions, adjacent vitreous body as well as measurement of morphometric data.Methods: The study included 189 patients (239 eyes with peripheral retinal degeneration. 77 men and 112 women aged 18 to 84 underwent an ophthalmologic examination since November 2012 until October 2013. The peripheral retina was visualized with the help of optical coherence tomography («RTVue-100,» USA. The fundography was carried out using a Nikon NF505‑AF (Japan fundus camera. All patients were examined with a Goldmann lens.Results: Optical coherence tomography was used to evaluate different kinds of peripheral retinal degenerations, such as lattice and snail track degeneration, isolated retinal tears, cystoid retinal degeneration, pathological hyperpigmentation, retinoschisis and cobblestone degeneration. The following morphometric data were studied: dimensions of the lesion (average length, retinal thickness along the edge of the lesion, retinal thickness at the base of the lesion and the vitreoretinal interface.Conclusion: Optical coherence tomography is a promising in vivo visualization method which is useful in evaluation of peripheral retinal degenerations, vitreoretinal adhesions and tractions. It also provides a comprehensive protocolling system and monitoring. It will enable ophthalmologists to better define laser and surgical treatment indications and evaluate therapy effectiveness.

  8. Optical coherent tomography in diagnoses of peripheral retinal degenarations

    Directory of Open Access Journals (Sweden)

    O. G. Pozdeyeva

    2014-07-01

    Full Text Available Purpose: Studying the capabilities of optical coherence tomography (RTVue-100, OPTOVUE, USA in evaluation of peripheral retinal degenerations, vitreoretinal adhesions, adjacent vitreous body as well as measurement of morphometric data.Methods: The study included 189 patients (239 eyes with peripheral retinal degeneration. 77 men and 112 women aged 18 to 84 underwent an ophthalmologic examination since November 2012 until October 2013. The peripheral retina was visualized with the help of optical coherence tomography («RTVue-100,» USA. The fundography was carried out using a Nikon NF505‑AF (Japan fundus camera. All patients were examined with a Goldmann lens.Results: Optical coherence tomography was used to evaluate different kinds of peripheral retinal degenerations, such as lattice and snail track degeneration, isolated retinal tears, cystoid retinal degeneration, pathological hyperpigmentation, retinoschisis and cobblestone degeneration. The following morphometric data were studied: dimensions of the lesion (average length, retinal thickness along the edge of the lesion, retinal thickness at the base of the lesion and the vitreoretinal interface.Conclusion: Optical coherence tomography is a promising in vivo visualization method which is useful in evaluation of peripheral retinal degenerations, vitreoretinal adhesions and tractions. It also provides a comprehensive protocolling system and monitoring. It will enable ophthalmologists to better define laser and surgical treatment indications and evaluate therapy effectiveness.

  9. Complex sine-Gordon Equation in Coherent Optical Pulse Propagation

    CERN Document Server

    Park, Q H

    1999-01-01

    It is shown that the McCall-Hahn theory of self-induced transparency in coherent optical pulse propagation can be identified with the complex sine-Gordon theory in the sharp line limit. We reformulate the theory in terms of the deformed gauged Wess-Zumino-Witten sigma model and address various new aspects of self-induced transparency.

  10. Heartbeat OCT: In vivo intravascular megahertz-optical coherence tomography

    NARCIS (Netherlands)

    T. Wang (Tianshi); A.F.H. Pfeiffer (Andreas); E.S. Regar (Eveline); W. Wieser (Wolfgang); H.M.M. van Beusekom (Heleen); C.T. Lancée (Charles); T. Springeling (Tirza); I. Krabbendam (Ilona); A.F.W. van der Steen (Ton); R. Huber (Roman); G. van Soest (Gijs)

    2015-01-01

    textabstractCardiac motion artifacts, non-uniform rotational distortion and undersampling affect the image quality and the diagnostic impact of intravascular optical coherence tomography (IV-OCT). In this study we demonstrate how these limitations of IV-OCT can be addressed by using an imaging syste

  11. Generation of optical coherent state superpositions for quantum information processing

    DEFF Research Database (Denmark)

    Tipsmark, Anders

    2012-01-01

    I dette projektarbejde med titlen “Generation of optical coherent state superpositions for quantum information processing” har målet været at generere optiske kat-tilstande. Dette er en kvantemekanisk superpositions tilstand af to koherente tilstande med stor amplitude. Sådan en tilstand er...

  12. Internal fingerprint zone detection in optical coherence tomography fingertip scans

    CSIR Research Space (South Africa)

    Darlow, LN

    2015-04-01

    Full Text Available Optical coherence tomography (OCT) is a high-resolution imaging technology capable of capturing a three-dimensional (3-D) representation of fingertip skin. The papillary junction—a junction layer of skin containing the same topographical features...

  13. Ultrahigh resolution optical coherence tomography using a superluminescent light source

    NARCIS (Netherlands)

    Kowalevicz, Andrew M.; Ko, Tony; Hartl, Ingmar; Fujimoto, James G.; Pollnau, Markus; Salathé, René P.

    2002-01-01

    A superluminescent Ti:Al2O3 crystal is demonstrated as a light source for ultrahigh resolution optical coherence tomography (OCT). Single spatial mode, fiber coupled output powers of ~40 μW can be generated with 138 nm bandwidth using a 5 W frequency doubled, diode pumped laser, pumping a thin Ti:Al

  14. Spectral domain optical coherence tomography and microperimetry in foveal hypoplasia

    Directory of Open Access Journals (Sweden)

    Swakshyar Saumya Pal

    2011-01-01

    Full Text Available A case of foveal hypoplasia associated with ocular albinism with anatomic and functional changes by various techniques using spectral domain optical coherence tomography (SD-OCT, microperimeter and confocal scanning laser ophthalmoscope is described. This case highlights the importance of microperimeter in detecting the functional abnormalities of vision and SD-OCT in identifying the retinal laminar abnormalities in foveal hypoplasia.

  15. Optics and photonics: essential technologies for our nation (technology & engineering)

    CERN Document Server

    Research, Committee on Harnessing Light: Capitalizing on Optical Science Trends and Challenges for Future; Sciences, Division on Engineering and Physical; Council, National Research

    2013-01-01

    Optics and photonics technologies are ubiquitous: they are responsible for the displays on smart phones and computing devices, optical fiber that carries the information in the internet, advanced precision manufacturing, enhanced defense capabilities, and a plethora of medical diagnostics tools. The opportunities arising from optics and photonics offer the potential for even greater societal impact in the next few decades, including solar power generation and new efficient lighting that could transform the nation's energy landscape and new optical capabilities that will be essential to support the continued exponential growth of the Internet. As described in the National Research Council report Optics and Photonics: Essential Technologies for our Nation, it is critical for the United States to take advantage of these emerging optical technologies for creating new industries and generating job growth. The report assesses the current state of optical science and engineering in the United States and abroad--incl...

  16. Double-clad hollow core photonic crystal fiber for coherent Raman endoscope.

    Science.gov (United States)

    Brustlein, Sophie; Berto, Pascal; Hostein, Richard; Ferrand, Patrick; Billaudeau, Cyrille; Marguet, Didier; Muir, Alistair; Knight, Jonathan; Rigneault, Hervé

    2011-06-20

    Performing label free coherent anti-Stokes Raman scattering (CARS) and stimulated Raman scattering (SRS) in endoscope imaging is a challenge, with huge potential clinical benefit. To date, this goal has remained inaccessible because of the inherent coherent Raman noise that is generated in the fiber itself. By developing double-clad hollow core photonic crystal fiber, we demonstrate coherent anti-Stokes Raman scattering and stimulated Raman scattering in an 'endoscope-like' scheme. Both the excitation beams and the collected CARS and SRS signals travel through the same fiber. No CARS and SRS signals are generated within the hollow core fiber even for temporally overlapping pump and Stokes beams, leading to excellent image quality. The CARS and SRS signals generated in the sample are coupled back into a high numerical aperture multimode cladding surrounding the central photonic crystal cladding. We demonstrate this scheme by imaging molecular vibrational bonds of organic crystal deposited on a glass surface.

  17. Simultaneous measurement of group refractive index and thickness of optical samples using optical coherence tomography.

    Science.gov (United States)

    Cheng, Hsu-Chih; Liu, Yi-Cheng

    2010-02-10

    Optical coherence tomography (OCT), based on a Michelson interferometer and utilizing low coherence light as the optical source, is a novel technique for the noninvasive imaging of optical scattering media. A simple OCT scheme based on a 3 x 3 fiber coupler is presented for the simultaneous measurement of the refractive index and thickness of optical samples. The proposed system enables the refractive index and thickness to be determined without any prior knowledge of the sample parameters and is characterized by a simple and compact configuration, a straightforward measurement procedure, and a low cost. The feasibility of the proposed approach is demonstrated experimentally using BK7 and B270 optical glass samples.

  18. Simultaneous measurement of group refractive index and thickness of optical samples using optical coherence tomography

    Energy Technology Data Exchange (ETDEWEB)

    Cheng, Hsu-Chih; Liu, Yi-Cheng

    2010-02-10

    Optical coherence tomography (OCT), based on a Michelson interferometer and utilizing low coherence light as the optical source, is a novel technique for the noninvasive imaging of optical scattering media. A simple OCT scheme based on a 3x3 fiber coupler is presented for the simultaneous measurement of the refractive index and thickness of optical samples. The proposed system enables the refractive index and thickness to be determined without any prior knowledge of the sample parameters and is characterized by a simple and compact configuration, a straightforward measurement procedure, and a low cost. The feasibility of the proposed approach is demonstrated experimentally using BK7 and B270 optical glass samples.

  19. Statistical Properties of Photon-Added Two-Mode Squeezed Coherent States

    Science.gov (United States)

    Wang, Zhen; Li, Heng-Mei; Yuan, Hong-Chun; Wan, Zhi-Long; Meng, Xiang-Guo

    2016-12-01

    The nonclassical and non-Gaussian quantum states—photon-added two-mode squeezed coherent states have been theoretically introduced by adding multiple photons to each mode of the two-mode squeezed coherent states. Starting from the new expression of two-mode squeezing operator in entangled states representation, the normalization factor is obtained, which is directly related to bivariate Hermite polynomials. The sub-Poissonian photon statistics, cross-correlation between two modes, partial negative Wigner function are observed, which fully reflect the nonclassicality of the target states. The negative Wigner function often display non-Gaussian distribution meanwhile. The investigations may provide experimentalists with some better references in quantum engineering.

  20. Optical characterication of probes for photon scanning tunnelling microscopy

    DEFF Research Database (Denmark)

    Vohnsen, Brian; Bozhevolnyi, Sergey I.

    1999-01-01

    The photon scanning tunnelling microscope is a well-established member of the family of scanning near-field optical microscopes used for optical imaging at the sub-wavelength scale. The quality of the probes, typically pointed uncoated optical fibres, used is however difficult to evaluate...

  1. Design and characterization of SiON integrated optics components for optical coherence tomography

    NARCIS (Netherlands)

    Nguyen, V. Duc; Kalkman, J.; Ismail, N.; Sun, F.; Worhoff, Kerstin; Driessen, A.; Pollnau, Markus; van Leeuwen, Ton

    2009-01-01

    Optical coherence tomography (OCT) is a technique for high resolution imaging of biological tissues with a depth range of a few millimeters. OCT is based on interferometry to enable depth ranging. Currently, optical components for OCT are rather bulky and expensive; the use of integrated optical

  2. Coherent Effects in Tiny Optics: Tunneling Through the Looking Glass

    Science.gov (United States)

    Smith, David D.

    2003-01-01

    I will discuss two types of one-dimensional photonic bandgap (PBG) effects that can arise in systems of coupled spherical resonators: (1) nearly-free-photon Fabry-Perot photonic bands that arise in quarter-wave concentrically stratified spheres and, (2) tight- binding photonic bands that arise in weakly-coupled mutually-resonant spheres as a result of whispering-gallery mode splitting. These effects can be derived directly from Mie theory, in a more straightforward manner, by exploiting an analogy with stratified planar systems. For odd numbers of mutually-resonant lossless coupled ring resonators, the circulating intensity can increase exponentially with the number of resonators, which can potentially be exploited for the development of advanced sensors. For even numbers of resonators, mode splitting and classical destructive interference lead to a cancellation of absorption and slow light on-resonance, reminiscent of electromagnetic induced transparency. The analogy between these coherent photon trapping effects and population trapping in an atomic system will be explored.

  3. Coherent DWDM technology for high speed optical communications

    Science.gov (United States)

    Saunders, Ross

    2011-10-01

    The introduction of coherent digital optical transmission enables a new generation of high speed optical data transport and fiber impairment mitigation. An initial implementation of 40 Gb/s coherent systems using Dual Polarization Quadrature Phase Shift Keying (DP-QPSK) is already being installed in carrier networks. New systems running at 100 Gb/s DP-QPSK data rate are in development and early technology lab and field trial phase. Significant investment in the 100 Gb/s ecosystem (optical components, ASICs, transponders and systems) bodes well for commercial application in 2012 and beyond. Following in the footsteps of other telecommunications fields such as wireless and DSL, we can expect coherent optical transmission to evolve from QPSK to higher order modulations schemes such as Mary PSK and/or QAM. This will be an interesting area of research in coming years and poses significant challenges in terms of electro-optic, DSP, ADC/DAC design and fiber nonlinearity mitigation to reach practical implementation ready for real network deployments.

  4. Evaluation of dental enamel caries assessment using Quantitative Light Induced Fluorescence and Optical Coherence Tomography.

    Science.gov (United States)

    Maia, Ana Marly Araújo; de Freitas, Anderson Zanardi; de L Campello, Sergio; Gomes, Anderson Stevens Leônidas; Karlsson, Lena

    2016-06-01

    An in vitro study of morphological alterations between sound dental structure and artificially induced white spot lesions in human teeth, was performed through the loss of fluorescence by Quantitative Light-Induced Fluorescence (QLF) and the alterations of the light attenuation coefficient by Optical Coherence Tomography (OCT). To analyze the OCT images using a commercially available system, a special algorithm was applied, whereas the QLF images were analyzed using the software available in the commercial system employed. When analyzing the sound region against white spot lesions region by QLF, a reduction in the fluorescence intensity was observed, whilst an increase of light attenuation by the OCT system occurred. Comparison of the percentage of alteration between optical properties of sound and artificial enamel caries regions showed that OCT processed images through the attenuation of light enhanced the tooth optical alterations more than fluorescence detected by QLF System. QLF versus OCT imaging of enamel caries: a photonics assessment.

  5. Investigations of Optical Coherence Properties in an Erbium-doped Silicate Fiber for Quantum State Storage

    CERN Document Server

    Staudt, M U; Afzelius, M; Jaccard, D; Tittel, W; Gisin, Nicolas; Staudt, Matthias U.; Hastings-Simon, Sara R.; Afzelius, Mikael; Jaccard, Didier; Tittel, Wolfgang; Gisin, Nicolas

    2006-01-01

    We studied optical coherence properties of the 1.53 $\\mu$m telecommunication transition in an Er$^{3+}$-doped silicate optical fiber through spectral holeburning and photon echoes. We find decoherence times of up to 3.8 $\\mu$s at a magnetic field of 2.2 Tesla and a temperature of 150 mK. A strong magnetic-field dependent optical dephasing was observed and is believed to arise from an interaction between the electronic Er$^{3+}$ spin and the magnetic moment of tunneling modes in the glass. Furthermore, we observed fine-structure in the Erbium holeburning spectrum originating from superhyperfine interaction with $^{27}$Al host nuclei. Our results show that Er$^{3+}$-doped silicate fibers are promising material candidates for quantum state storage.

  6. Characterization of the dental pulp using optical coherence tomography

    Science.gov (United States)

    Kauffman, C. M. F.; Carvalho, M. T.; Araujo, R. E.; Freitas, A. Z.; Zezell, D. M.; Gomes, A. S. L.

    2006-02-01

    The inner structure of teeth, i.e. the root canal anatomy, is very complex. However a good knowledge of endodontic architecture is the first step towards successful endodontic treatment. Optical coherence tomography (OCT) is a powerful technique to generate images of hard and soft tissue. Its images show dependency on the optical properties of the tissue under analysis. Changes in the scattering and absorption of tissues can be observed through the OCT images. In this work, we used optical coherence tomography to perform in vitro studies of the inner structure of the first molar of albino rats (Rattus norvegicus). Focusing on the pulp chamber and in the root canal, we compare the images generated with the OCT technique to the histology. We are analyzing the feasibility of OCT to help on the diagnostic of endodontic diseases.

  7. Quantum optical coherence in cytoskeletal microtubules: implications for brain function.

    Science.gov (United States)

    Jibu, M; Hagan, S; Hameroff, S R; Pribram, K H; Yasue, K

    1994-01-01

    'Laser-like,' long-range coherent quantum phenomena may occur biologically within cytoskeletal microtubules. This paper presents a theoretical prediction of the occurrence in biological media of the phenomena which we term 'superradiance' and 'self-induced transparency'. Interactions between the electric dipole field of water molecules confined within the hollow core of microtubules and the quantized electromagnetic radiation field are considered, and microtubules are theorized to play the roles of non-linear coherent optical devices. Superradiance is a specific quantum mechanical ordering phenomenon with characteristic times much shorter than those of thermal interaction. Consequently, optical signalling (and computation) in microtubules would be free from both thermal noise and loss. Superradiant optical computing in networks of microtubules and other cytoskeletal structures may provide a basis for biomolecular cognition and a substrate for consciousness.

  8. Coherent broadband mid-infrared supercontinuum generation in As2Se3 photonic crystal fiber

    CERN Document Server

    Yuan, Wu

    2013-01-01

    The generation of fully coherent broadband mid-infrared (MIR) supercontinuum (SC) from 2.3 um to 8.3 um is demonstrated by using a 4.1 um pump and an As2Se3 photonic crystal fiber (PCF).By introducing the random quantum noise and the power instability on the input pulse and by numerically implementing the Young,s double slits experiment, we examine the coherence properties across the SC spectrum. It is found that the coherence of this MIR SC source depends strongly on the input pulse duration, the peak power, the power stability, and the zero-dispersion wavelength (ZDW) of the As2Se3 PCF.The optimal conditions for the MIR SC with a maximal coherent bandwidth are identified.

  9. Optical Coherence Tomography to Assess Neurodegeneration in Multiple Sclerosis.

    Science.gov (United States)

    Petzold, Axel

    2016-01-01

    Retinal spectral domain optical coherence tomography (OCT) has emerged as a clinical and research tool in multiple sclerosis (MS) and optic neuritis (ON). This chapter summarizes a short OCT protocol as included in international consensus guidelines. The protocol was written for hands-on style such that both clinicians and OCT technicians can make use of it. The protocol is suitable for imaging of the optic nerve head and macular regions as a baseline for follow-up investigations, individual layer segmentation, and diagnostic assessment.

  10. Multi-aperture digital coherent combining for free-space optical communication receivers.

    Science.gov (United States)

    Geisler, David J; Yarnall, Timothy M; Stevens, Mark L; Schieler, Curt M; Robinson, Bryan S; Hamilton, Scott A

    2016-06-13

    Space-to-ground optical communication systems can benefit from reducing the size, weight, and power profiles of space terminals. One way of reducing the required power-aperture product on a space platform is to implement effective, but costly, single-aperture ground terminals with large collection areas. In contrast, we present a ground terminal receiver architecture in which many small less-expensive apertures are efficiently combined to create a large effective aperture while maintaining excellent receiver sensitivity. This is accomplished via coherent detection behind each aperture followed by digitization. The digitized signals are then combined in a digital signal processing chain. Experimental results demonstrate lossless coherent combining of four lasercom signals, at power levels below 0.1 photons/bit/aperture.

  11. Measurement of tissue optical properties with optical coherence tomography: Implication for noninvasive blood glucose concentration monitoring

    Science.gov (United States)

    Larin, Kirill V.

    Approximately 14 million people in the USA and more than 140 million people worldwide suffer from diabetes mellitus. The current glucose sensing technique involves a finger puncture several times a day to obtain a droplet of blood for analysis. There have been enormous efforts by many scientific groups and companies to quantify glucose concentration noninvasively using different optical techniques. However, these techniques face limitations associated with low sensitivity, accuracy, and insufficient specificity of glucose concentrations over a physiological range. Optical coherence tomography (OCT), a new technology, is being applied for noninvasive imaging in tissues with high resolution. OCT utilizes sensitive detection of photons coherently scattered from tissue. The high resolution of this technique allows for exceptionally accurate measurement of tissue scattering from a specific layer of skin compared with other optical techniques and, therefore, may provide noninvasive and continuous monitoring of blood glucose concentration with high accuracy. In this dissertation work I experimentally and theoretically investigate feasibility of noninvasive, real-time, sensitive, and specific monitoring of blood glucose concentration using an OCT-based biosensor. The studies were performed in scattering media with stable optical properties (aqueous suspensions of polystyrene microspheres and milk), animals (New Zealand white rabbits and Yucatan micropigs), and normal subjects (during oral glucose tolerance tests). The results of these studies demonstrated: (1) capability of the OCT technique to detect changes in scattering coefficient with the accuracy of about 1.5%; (2) a sharp and linear decrease of the OCT signal slope in the dermis with the increase of blood glucose concentration; (3) the change in the OCT signal slope measured during bolus glucose injection experiments (characterized by a sharp increase of blood glucose concentration) is higher than that measured in

  12. Ultra-fast coherent optical system for active remote sensing applications

    Science.gov (United States)

    Datta, Shubhashish; Becker, Don; Joshi, Abhay; Howard, Roy

    2008-04-01

    Active optical remote sensing has numerous applications including battlefield target recognition and tracking, atmospheric monitoring, structural monitoring, collision avoidance systems, and terrestrial mapping. The maximum propagation distance in LIDAR sensors is limited by the signal attenuation. Sensor range could be improved by increasing the transmitted pulse energy, at the expense of reduced resolution and information bandwidth. Coherent detection can operate at low optical power levels without sacrificing sensor bandwidth. Utilizing a high power LO laser to increase the receiver gain, coherent systems provide shot noise-limited gain thereby increasing the sensing range. To fully exploit high LO powers without incurring performance penalties due to the RIN of the LO, high power handling balanced photodiodes are used. The coherent system has superior dynamic range, bandwidth, and noise performance than small-signal APD-based systems. Coherent detection is a linear process that is sensitive to the amplitude, phase and polarization of the received signal. Therefore, Doppler shifts and vibration signatures can be easily recovered. RF adaptive filtering following photodetection enables channel equalization, atmospheric turbulence compensation, and efficient background light filtering. We demonstrate a coherent optical transmission system using 15mA high power handling balanced photodetectors. This system has an IF linewidth <1Hz, employing a proprietary phase locked loop design. Data is presented for 100ps pulsed transmission. We have demonstrated amplitude and phase modulated 10Gb/s communication links with sensitivities of 132 and 72 photons per bit respectively. Investigations into system performance in the presence of laboratory induced atmospheric turbulence are shown.

  13. Fourier phase in Fourier-domain optical coherence tomography.

    Science.gov (United States)

    Uttam, Shikhar; Liu, Yang

    2015-12-01

    Phase of an electromagnetic wave propagating through a sample-of-interest is well understood in the context of quantitative phase imaging in transmission-mode microscopy. In the past decade, Fourier-domain optical coherence tomography has been used to extend quantitative phase imaging to the reflection-mode. Unlike transmission-mode electromagnetic phase, however, the origin and characteristics of reflection-mode Fourier phase are poorly understood, especially in samples with a slowly varying refractive index. In this paper, the general theory of Fourier phase from first principles is presented, and it is shown that Fourier phase is a joint estimate of subresolution offset and mean spatial frequency of the coherence-gated sample refractive index. It is also shown that both spectral-domain phase microscopy and depth-resolved spatial-domain low-coherence quantitative phase microscopy are special cases of this general theory. Analytical expressions are provided for both, and simulations are presented to explain and support the theoretical results. These results are further used to show how Fourier phase allows the estimation of an axial mean spatial frequency profile of the sample, along with depth-resolved characterization of localized optical density change and sample heterogeneity. Finally, a Fourier phase-based explanation of Doppler optical coherence tomography is also provided.

  14. Multiple Scattering Model for Optical Coherence Tomography with Rytov Approximation

    KAUST Repository

    Li, Muxingzi

    2017-04-24

    Optical Coherence Tomography (OCT) is a coherence-gated, micrometer-resolution imaging technique that focuses a broadband near-infrared laser beam to penetrate into optical scattering media, e.g. biological tissues. The OCT resolution is split into two parts, with the axial resolution defined by half the coherence length, and the depth-dependent lateral resolution determined by the beam geometry, which is well described by a Gaussian beam model. The depth dependence of lateral resolution directly results in the defocusing effect outside the confocal region and restricts current OCT probes to small numerical aperture (NA) at the expense of lateral resolution near the focus. Another limitation on OCT development is the presence of a mixture of speckles due to multiple scatterers within the coherence length, and other random noise. Motivated by the above two challenges, a multiple scattering model based on Rytov approximation and Gaussian beam optics is proposed for the OCT setup. Some previous papers have adopted the first Born approximation with the assumption of small perturbation of the incident field in inhomogeneous media. The Rytov method of the same order with smooth phase perturbation assumption benefits from a wider spatial range of validity. A deconvolution method for solving the inverse problem associated with the first Rytov approximation is developed, significantly reducing the defocusing effect through depth and therefore extending the feasible range of NA.

  15. Fast Cherenkov model of optical photons generation and transportation

    CERN Document Server

    The ATLAS collaboration

    2017-01-01

    This note describes the technical details of Fast Cherenkov model of optical photons generation and transportation: in particular, the mechanism of Cherenkov photons transportation through the straight bar geometry. As an example of usage, the implemetation of the method inside Quartic detector simulation in GEANT4 will be presented and compared to the nominal results.

  16. All-optical gates based on photonic crystal resonators

    Science.gov (United States)

    Moille, Grégory; De Rossi, Alfredo; Combrié, Sylvain

    2016-04-01

    We briefly review the technology of advanced nonlinear resonators for all-optical gating with a specific focus on the application of high-performance signal sampling and on the properties of III-V semiconductor photonic crystals

  17. Efficient out-coupling of high-purity single photons from a coherent quantum dot in a photonic-crystal cavity

    DEFF Research Database (Denmark)

    Madsen, Kristian Høeg; Ates, Serkan; Liu, J.

    2014-01-01

    We demonstrate a single-photon collection efficiency of (44.3 ± 2.1)% from a quantum dot in a low-Q mode of a photonic-crystal cavity with a single-photon purity of g(2)(0) = (4 ± 5)% recorded above the saturation power. The high efficiency is directly confirmed by detecting up to 962 ± 46...... kilocounts per second on a single-photon detector on another quantum dot coupled to the cavity mode. The high collection efficiency is found to be broadband, as is explained by detailed numerical simulations. Cavity-enhanced efficient excitation of quantum dots is obtained through phonon-mediated excitation...... and under these conditions, single-photon indistinguishability measurements reveal long coherence times reaching 0.77 ± 0.19 ns in a weak-excitation regime. Our work demonstrates that photonic crystals provide a very promising platform for highly integrated generation of coherent single photons including...

  18. Evaluation of effective noise bandwidth for broadband optical coherence tomography operation.

    Science.gov (United States)

    Cernat, Ramona; Dobre, George M; Bradu, Adrian; Podoleanu, Adrian Gh

    2009-04-01

    Key noise parameters in optical coherence tomography (OCT) systems employing splitters with a nonflat spectral response are evaluated using a supercontinuum fiber laser source with a spectrum of 450 nm-1700 nm and a time domain OCT architecture based on 1300 nm fiber splitters. The spectral behavior of the splitter leading to balanced detection is measured over a range of 300 nm. Because of spectrally different signals at the balanced detector input a residual excess photon noise term results. A rigorous treatment of this noise term [Appl. Opt.43, 4802 (2004)] introduced two new quantities that take into account the spectral properties of the coupler. In this report, we have evaluated these two noise bandwidth quantities and comparatively assessed the noise behavior predicted by the classical theory with the theory based on the two new noise bandwidths. We show that under certain operating parameters, the additional excess photon noise is twice that predicted for a coupler with a flat spectral response.

  19. Optical properties of active photonic materials

    OpenAIRE

    Zeng, Yong

    2007-01-01

    Because of the generation of polaritons, which are quasiparticles possessing the characteristics of both photonics and electronics, active photonic materials offer a possible solution to transfer electromagnetic energy below the diffraction limit and further increase the density of photonic integrated circuits. A theoretical investigation of these exciting materials is, therefore, very important for practical applications. Four different kinds of polaritons have been studied in this thesis, (...

  20. Generation of optical Schr\\"odinger cat states by number-resolved photon subtraction from squeezed vacuum

    CERN Document Server

    Gerrits, Thomas; Clement, Tracy S; Calkins, Brice; Lita, Adriana E; Miller, Aaron J; Migdall, Alan L; Nam, Sae Woo; Mirin, Richard P; Knill, Emanuel

    2010-01-01

    Optical Schr\\"odinger cat states will have many applications in the fields of quantum information and high precision metrology in the future. Also, quantum states that cannot be characterized or measured by means of coincidence measurements require characterization with high efficiency and real photon-number resolving detectors. Here we report results from experiments creating heralded photonic cat states by subtracting up to three photons from a squeezed vacuum light pulse. We utilized our photon-number-resolving transition edge sensor with a quantum efficiency of 85% to detect the number of heralding photons. This is the first experiment utilizing the full photon-number-resolving capabilities of this photon detector. The optical cat state that was produced when subtracting three photons had a mean photon number of 2.75 and a fidelity of 0.59 +0.04/-0.14 compared to an ideal cat state consisting of an equal superposition of two optical coherent states. Furthermore, we observe an increase of the cat states si...

  1. Coherent pulse implementations of quantum cryptography protocols resistant to photon number splitting attacks

    CERN Document Server

    Acin, A; Scarani, V; Acin, Antonio; Gisin, Nicolas; Scarani, Valerio

    2004-01-01

    A new class of quantum cryptography (QC) protocols that are robust against the most general photon number splitting attacks in a weak coherent pulse implementation has been recently proposed. In this article we give a quite exhaustive analysis of several eavesdropping attacks on these schemes. The eavesdropper (Eve) is supposed to have unlimited technological power while the honest parties (Alice and Bob) use present day technology, in particular an attenuated laser as an approximation of a single-photon source. They exploit the nonorthogonality of quantum states for decreasing the information accessible to Eve in the multi-photon pulses accidentally produced by the imperfect source. An implementation of some of these protocols using present day technology allow for a secure key distribution up to distances of $\\sim$ 150 km. We also show that strong-pulse implementations, where a strong pulse is included as a reference, allow for key distribution robust against photon number splitting attacks.

  2. Probing myocardium biomechanics using quantitative optical coherence elastography

    Science.gov (United States)

    Wang, Shang; Lopez, Andrew L.; Morikawa, Yuka; Tao, Ge; Li, Jiasong; Larina, Irina V.; Martin, James F.; Larin, Kirill V.

    2015-03-01

    We present a quantitative optical coherence elastographic method for noncontact assessment of the myocardium elasticity. The method is based on shear wave imaging optical coherence tomography (SWI-OCT), where a focused air-puff system is used to induce localized tissue deformation through a low-pressure short-duration air stream and a phase-sensitive OCT system is utilized to monitor the propagation of the induced tissue displacement with nanoscale sensitivity. The 1-D scanning of M-mode OCT imaging and the application of optical phase retrieval and mapping techniques enable the reconstruction and visualization of 2-D depth-resolved shear wave propagation in tissue with ultra-high frame rate. The feasibility of this method in quantitative elasticity measurement is demonstrated on tissue-mimicking phantoms with the estimated Young's modulus compared with uniaxial compression tests. We also performed pilot experiments on ex vivo mouse cardiac muscle tissues with normal and genetically altered cardiomyocytes. Our results indicate this noncontact quantitative optical coherence elastographic method can be a useful tool for the cardiac muscle research and studies.

  3. Proposal for generating a two-photon added coherent state via down-conversion with a single crystal

    Energy Technology Data Exchange (ETDEWEB)

    Kalamidas, Demetrios [Institute for Ultrafast Spectroscopy and Lasers, City College of the City University of New York, 138th Street and Convent Avenue, New York, NY 10031 (United States); Gerry, Christopher C. [Department of Physics and Astronomy, Lehman College, City University of New York, Bronx, NY 10468-1589 (United States)], E-mail: christopher.gerry@lehman.cuny.edu; Benmoussa, Adil [Department of Physics and Astronomy, Lehman College, City University of New York, Bronx, NY 10468-1589 (United States)

    2008-03-10

    Zavatta et al. [A. Zavatta, S. Viciani, M. Bellini, Science 306 (2004) 660; A. Zavatta, S. Viciani, M. Bellini, Phys. Rev. A 72 (2006) 023820], using parametric down-conversion, have carried out experiments to conditionally generate a single-photon added coherent state. In this Letter, we propose an extension of their method in order to generate the two-photon added coherent state, and point the way toward generating m-photon added coherent states for m>2, all using only one down-conversion crystal.

  4. Gabor-based fusion technique for Optical Coherence Microscopy.

    Science.gov (United States)

    Rolland, Jannick P; Meemon, Panomsak; Murali, Supraja; Thompson, Kevin P; Lee, Kye-sung

    2010-02-15

    We recently reported on an Optical Coherence Microscopy technique, whose innovation intrinsically builds on a recently reported - 2 microm invariant lateral resolution by design throughout a 2 mm cubic full-field of view - liquid-lens-based dynamic focusing optical probe [Murali et al., Optics Letters 34, 145-147, 2009]. We shall report in this paper on the image acquisition enabled by this optical probe when combined with an automatic data fusion method developed and described here to produce an in-focus high resolution image throughout the imaging depth of the sample. An African frog tadpole (Xenopus laevis) was imaged with the novel probe and the Gabor-based fusion technique, demonstrating subcellular resolution in a 0.5 mm (lateral) x 0.5 mm (axial) without the need, for the first time, for x-y translation stages, depth scanning, high-cost adaptive optics, or manual intervention. In vivo images of human skin are also presented.

  5. Digital signal processing techniques for coherent optical communication

    Science.gov (United States)

    Goldfarb, Gilad

    Coherent detection with subsequent digital signal processing (DSP) is developed, analyzed theoretically and numerically and experimentally demonstrated in various fiber-optic transmission scenarios. The use of DSP in conjunction with coherent detection unleashes the benefits of coherent detection which rely on the preservaton of full information of the incoming field. These benefits include high receiver sensitivity, the ability to achieve high spectral-efficiency and the use of advanced modulation formats. With the immense advancements in DSP speeds, many of the problems hindering the use of coherent detection in optical transmission systems have been eliminated. Most notably, DSP alleviates the need for hardware phase-locking and polarization tracking, which can now be achieved in the digital domain. The complexity previously associated with coherent detection is hence significantly diminished and coherent detection is once gain considered a feasible detection alternative. In this thesis, several aspects of coherent detection (with or without subsequent DSP) are addressed. Coherent detection is presented as a means to extend the dispersion limit of a duobinary signal using an analog decision-directed phase-lock loop. Analytical bit-error ratio estimation for quadrature phase-shift keying signals is derived. To validate the promise for high spectral efficiency, the orthogonal-wavelength-division multiplexing scheme is suggested. In this scheme the WDM channels are spaced at the symbol rate, thus achieving the spectral efficiency limit. Theory, simulation and experimental results demonstrate the feasibility of this approach. Infinite impulse response filtering is shown to be an efficient alternative to finite impulse response filtering for chromatic dispersion compensation. Theory, design considerations, simulation and experimental results relating to this topic are presented. Interaction between fiber dispersion and nonlinearity remains the last major challenge

  6. Generation of three-mode W-type entangled coherent states in free-travelling optical fields

    Institute of Scientific and Technical Information of China (English)

    Yu Guo; Leman Kuang

    2008-01-01

    @@ We propose a scheme for generation of three-mode W-type entangled coherent states (ECSs) in freetravelling optical fields by using a single-photon source, coherent state sources, beam splitters, photodetectors, and three-mode cross-Kerr media. The scheme consists of a Mach-Zehnder interferometer (MZI)in which each arm contains a cross-Kerr medium. We calculate the success probability of the generated W-type ECSs, and the total success probability is unity under the ideal conditions.

  7. Negative Avalanche Feedback Detectors for Photon-Counting Optical Communications

    Science.gov (United States)

    Farr, William H.

    2009-01-01

    Negative Avalanche Feedback photon counting detectors with near-infrared spectral sensitivity offer an alternative to conventional Geiger mode avalanche photodiode or phototube detectors for free space communications links at 1 and 1.55 microns. These devices demonstrate linear mode photon counting without requiring any external reset circuitry and may even be operated at room temperature. We have now characterized the detection efficiency, dark count rate, after-pulsing, and single photon jitter for three variants of this new detector class, as well as operated these uniquely simple to use devices in actual photon starved free space optical communications links.

  8. Negative Avalanche Feedback Detectors for Photon-Counting Optical Communications

    Science.gov (United States)

    Farr, William H.

    2009-01-01

    Negative Avalanche Feedback photon counting detectors with near-infrared spectral sensitivity offer an alternative to conventional Geiger mode avalanche photodiode or phototube detectors for free space communications links at 1 and 1.55 microns. These devices demonstrate linear mode photon counting without requiring any external reset circuitry and may even be operated at room temperature. We have now characterized the detection efficiency, dark count rate, after-pulsing, and single photon jitter for three variants of this new detector class, as well as operated these uniquely simple to use devices in actual photon starved free space optical communications links.

  9. Construction of photon-added spin coherent states and their statistical properties

    Energy Technology Data Exchange (ETDEWEB)

    Berrada, K., E-mail: kberrada@ictp.it [Al Imam Mohammad Ibn Saud Islamic University (IMSIU), College of Science, Department of Physics, Riyadh (Saudi Arabia); The Abdus Salam International Centre for Theoretical Physics, Strada Costiera 11, Miramare-Trieste (Italy)

    2015-07-15

    In the present work, we construct and investigate some properties of the photon-added spin coherent states (PA-SCSs). The Klauder’s minimal set of conditions required to obtain coherent states are discussed. We give the analytical form for the positive weight function in the resolution of unity. Finally, we examine the statistical properties of the PA-SCSs in terms of different parameters using the Mandel’s Q-parameter. All these quantities are expressed in terms of hypergeometric and Meijer G-functions, and so, the PA-SCSs are a new field of application for these functions.

  10. Theory of Interferometric Photon-Correlation Measurements: Differentiating Coherent from Chaotic Light

    CERN Document Server

    Lebreton, A; Braive, R; Sagnes, I; Robert-Philip, I; Beveratos, A

    2013-01-01

    Interferometric photon-correlation measurements, which correspond to the second-order intensity cross-correlations between the two output ports of an unbalanced Michelson interferometer, are sensitive to both amplitude and phase fluctuations of an incoming beam of light. Here, we present the theoretical framework behind these measurements and show that they can be used to unambiguously differentiate a coherent wave undergoing dynamical amplitude and phase fluctuations from a chaotic state of light. This technique may thus be used to characterize the output of nanolasers and monitor the onset of coherent emission.

  11. Direct Observation of the Coherent Nuclear Response after the Absorption of a Photon

    Science.gov (United States)

    Liebel, M.; Schnedermann, C.; Bassolino, G.; Taylor, G.; Watts, A.; Kukura, P.

    2014-06-01

    How molecules convert light energy to perform a specific transformation is a fundamental question in photophysics. Ultrafast spectroscopy reveals the kinetics associated with electronic energy flow, but little is known about how absorbed photon energy drives nuclear motion. Here we used ultrabroadband transient absorption spectroscopy to monitor coherent vibrational energy flow after photoexcitation of the retinal chromophore. In the proton pump bacteriorhodopsin, we observed coherent activation of hydrogen-out-of-plane wagging and backbone torsional modes that were replaced by unreactive coordinates in the solution environment, concomitant with a deactivation of the reactive relaxation pathway.

  12. Direct observation of the coherent nuclear response after the absorption of a photon.

    Science.gov (United States)

    Liebel, M; Schnedermann, C; Bassolino, G; Taylor, G; Watts, A; Kukura, P

    2014-06-13

    How molecules convert light energy to perform a specific transformation is a fundamental question in photophysics. Ultrafast spectroscopy reveals the kinetics associated with electronic energy flow, but little is known about how absorbed photon energy drives nuclear motion. Here we used ultrabroadband transient absorption spectroscopy to monitor coherent vibrational energy flow after photoexcitation of the retinal chromophore. In the proton pump bacteriorhodopsin, we observed coherent activation of hydrogen-out-of-plane wagging and backbone torsional modes that were replaced by unreactive coordinates in the solution environment, concomitant with a deactivation of the reactive relaxation pathway.

  13. Coherence Loss of Two-Photon Jaynes-Cummings Model in Dispersive Approximation

    Institute of Scientific and Technical Information of China (English)

    ZHOU Ling; GUO Yan-Qing; SONG He-Shan; LI Chong

    2004-01-01

    Completely solving the dissipative dynamics of nonlinear Jaynes-Cumming model is a very difficult task.In our recent work (Phys. Lett. A284 (2001) 156), we just obtained analytical results of the field dissipative dynamics of the nonlinear JCM. In the present paper, employing the perturbative expansion of master equation, we obtain the density operator of the system (field +atom). The coherence losses of the system and of the atom are investigated when two-photon process is involved. We also study the effect of different atomic initial states and the influence of the field amplitude on the atomic coherence loss.

  14. Quantum Interference between a Single-Photon Fock State and a Coherent State

    OpenAIRE

    Windhager, Armin; Suda, Martin; Pacher, Christoph; Peev, Momtchil; Poppe, Andreas

    2010-01-01

    We derive analytical expressions for the single mode quantum field state at the individual output ports of a beam splitter when a single-photon Fock state and a coherent state are incident on the input ports. The output states turn out to be a statistical mixture between a displaced Fock state and a coherent state. Consequently we are able to find an analytical expression for the corresponding Wigner function. Because of the generality of our calculations the obtained results are valid for al...

  15. Direct observation of the coherent nuclear response after the absorption of a photon

    CERN Document Server

    Liebel, Matz; Bassolino, Giovanni; Taylor, Garrick; Watts, Anthony; Kukura, Philipp

    2014-01-01

    How molecules convert light energy to perform a specific transformation is a fundamental question in photophysics. Ultrafast spectroscopy reveals the kinetics associated with electronic energy flow, but little is known about how absorbed photon energy drives nuclear or electronic motion. Here, we used ultrabroadband transient absorption spectroscopy to monitor coherent vibrational energy flow after photoexcitation of the retinal chromophore. In the proton pump bacteriorhodopsin we observed coherent activation of hydrogen wagging and backbone torsional modes that were replaced by unreactive coordinates in the solution environment, concomitant with a deactivation of the reactive relaxation pathway.

  16. Field Theory for Coherent Optical Pulse Propagation

    CERN Document Server

    Park, Q H

    1997-01-01

    We introduce a new notion of "matrix potential" to nonlinear optical systems. In terms of a matrix potential $g$, we present a gauge field theoretic formulation of the Maxwell-Bloch equation that provides a semiclassical description of the propagation of optical pulses through resonant multi-level media. We show that the Bloch part of the equation can solved identically through $g$ and the remaining Maxwell equation becomes a second order differential equation with reduced set of variables due to the gauge invariance of the system. Our formulation clarifies the (nonabelian) symmetry structure of the Maxwell-Bloch equations for various multi-level media in association with symmetric spaces $G/H$. In particular, we associate nondegenerate two-level system for self-induced transparency with $G/H=SU(2)/U(1)$ and three-level $\\L $- or V-systems with $G/H = SU(3)/U(2)$. We give a detailed analysis for the two-level case in the matrix potential formalism, and address various new properties of the system including so...

  17. Tomography of photon-added and photon-subtracted states

    NARCIS (Netherlands)

    Bazrafkan, MR; Man'ko, [No Value

    2003-01-01

    The purpose of this paper is to introduce symplectic and optical tomograms of photon-added and photon-subtracted quantum states. Explicit relations for the tomograms of photon-added and photon-subtracted squeezed coherent states and squeezed number states are obtained. Generating functions for the m

  18. Tomography of photon-added and photon-subtracted states

    NARCIS (Netherlands)

    Bazrafkan, MR; Man'ko, [No Value

    The purpose of this paper is to introduce symplectic and optical tomograms of photon-added and photon-subtracted quantum states. Explicit relations for the tomograms of photon-added and photon-subtracted squeezed coherent states and squeezed number states are obtained. Generating functions for the

  19. Tunnelling of Two-Level Atoms in Two-Photon Mazer:Atomic Coherence Effect and Statistics of Cavity Fields

    Institute of Scientific and Technical Information of China (English)

    何小灵; 杜四德; 周鲁卫; 汪启胜; 陈灏

    2004-01-01

    Tunnelling of a two-level atom is investigated in the two-photon mazer when the atom is initially prepared in a coherent superposition state and the cavity in various quantum states. For a strong coherent field, the tunnelling exhibits more regular oscillations but less remarkable switch effect than that in the one-photon mazer. It is discovered that in the presence of atomic coherence, the transmission probabilities in the ultracold regime are significantly different when the cavity field is initially in coherent, squeezed vacuum, even cat and odd cat states,respectively.

  20. Snapshot coherence-gated direct wavefront sensing for multi-photon microscopy

    NARCIS (Netherlands)

    Van Werkhoven, T.I.M.; Antonello, J.; Truong, H.H.; Verhaegen, M.; Gerritsen, H.C.; Keller, C.U.

    2014-01-01

    Deep imaging in turbid media such as biological tissue is challenging due to scattering and optical aberrations. Adaptive optics has the potential to compensate the tissue aberrations. We present a wavefront sensing scheme for multi-photon scanning microscopes using the pulsed, near-infrared light r

  1. Optical diode based on the chirality of guided photons

    CERN Document Server

    Sayrin, C; Mitsch, R; Albrecht, B; O'Shea, D; Schneeweiss, P; Volz, J; Rauschenbeutel, A

    2015-01-01

    Photons are nonchiral particles: their handedness can be both left and right. However, when light is transversely confined, it can locally exhibit a transverse spin whose orientation is fixed by the propagation direction of the photons. Confined photons thus have chiral character. Here, we employ this to demonstrate nonreciprocal transmission of light at the single-photon level through a silica nanofibre in two experimental schemes. We either use an ensemble of spin-polarised atoms that is weakly coupled to the nanofibre-guided mode or a single spin-polarised atom strongly coupled to the nanofibre via a whispering-gallery-mode resonator. We simultaneously achieve high optical isolation and high forward transmission. Both are controlled by the internal atomic state. The resulting optical diode is the first example of a new class of nonreciprocal nanophotonic devices which exploit the chirality of confined photons and which are, in principle, suitable for quantum information processing and future quantum optica...

  2. Results on the Coherent Interaction of High Energy Electrons and Photons in Oriented Single Crystals

    CERN Document Server

    Apyan, A; Badelek, B; Ballestrero, S; Biino, C; Birol, I; Cenci, P; Connell, S H; Eichblatt, S; Fonseca, T; Freund, A; Gorini, B; Groess, R; Ispirian, K; Ketel, T; Kononets, Y V; López, A; Mangiarotti, A; Van Rens, B; Sellschop, J P Friedel; Shieh, M; Sona, P; Strakhovenko, V M; Uggerhøj, Erik; Uggerhøj, U; Ünel, G; Velasco, M; Vilakazi, Z Z; Wessely, O; Kononets, Yu.V.

    2005-01-01

    The CERN-NA-59 experiment examined a wide range of electromagnetic processes for multi-GeV electrons and photons interacting with oriented single crystals. The various types of crystals and their orientations were used for producing photon beams and for converting and measuring their polarisation. The radiation emitted by 178 GeV unpolarised electrons incident on a 1.5 cm thick Si crystal oriented in the Coherent Bremsstrahlung (CB) and the String-of-Strings (SOS) modes was used to obtain multi-GeV linearly polarised photon beams. A new crystal polarimetry technique was established for measuring the linear polarisation of the photon beam. The polarimeter is based on the dependence of the Coherent Pair Production (CPP) cross section in oriented single crystals on the direction of the photon polarisation with respect to the crystal plane. Both a 1 mm thick single crystal of Germanium and a 4 mm thick multi-tile set of synthetic Diamond crystals were used as analyzers of the linear polarisation. A birefringence ...

  3. Optical fibers and photonics applications: topical tracks at Wilga conferences

    Science.gov (United States)

    Romaniuk, Ryszard S.

    2013-01-01

    This paper is a research survey of WILGA Symposium work, 2010-2012 Editions, concerned with Optical Fibers, Optoelectronic Devices, Sensors, Communication and Photonics Applications. It presents a digest of chosen technical work results shown by young researchers from different technical universities from this country during the three recent Wilga Symposia on Photonics and Web Engineering. Topical tracks of the symposia embraced, among others, nanomaterials and nanotechnologies for photonics, sensory and nonlinear optical fibers, object oriented design of hardware, photonic metrology, optoelectronics and photonics applications, photonics-electronics co-design, optoelectronic and electronic systems for astronomy and high energy physics experiments, photonic equipment for JET tokamak and pi-of-the sky experiments development. The symposium is an annual summary in the development of numerable Ph.D. theses carried out in this country in the area of advanced electronic and photonic systems. It is also a great occasion for SPIE, IEEE, OSA and PSP students to meet together in a large group spanning the whole country with guests from this part of Europe. A digest of Wilga references is presented [1-274]. Wilga Symposia play a role of an universal integrator of young science in photonics and related areas in this country and also in this part of Europe. More than 5000 young scientists participated in scientific Wilga meetings and discussions during the last nearly two decades. Over 2500 papers were published, including over 1000 in Proc. SPIE.

  4. Optical Coherence Tomography in Pulmonary Medicine

    Science.gov (United States)

    Murgu, Septimiu Dan; Brenner, Matthew; Chen, Zhongping; Suter, Melissa J.

    Advances in pulmonary diagnostics and therapeutics offer a major potential for optical imaging applications both in clinical practice and research settings. Complexities of pulmonary structures and function have restricted widespread OCT investigations and clinical applications, but these will likely be overcome by developments in OCT technology [1]. Some factors that have limited adaptation of OCT into the pulmonary setting in the past have been the shallow depth of penetration, resolution limitations, relatively slow access times, need to examine large surface areas with numerous branching airways, motion artifacts, as well as a need for development of practical imaging probes to reach the relevant locations in a minimally invasive way. Considerable recent engineering and analytical advances in OCT technology [2-8] have already overcome several of these obstacles and will enable much more extensive investigations into the role for structural and functional pulmonary OCT imaging [1].

  5. Oscillation behaviour in the photon-number distribution of squeezed coherent states

    Institute of Scientific and Technical Information of China (English)

    Wang Shuai; Zhang Xiao-Yan; Fan Hong-Yi

    2012-01-01

    From the normally ordered form of the density operator of a squeezed coherent state(SCS),we directly derive the compact expression of the SCS's photon-number distribution(PND).Besides the known oscillation characteristics,we find that the PND is a periodic function with a period of π and extremely sensitive to phase.If the squeezing is strong enough,and the compound phase which is relevant to the complex squeezing and displacement parameters are assigned appropriate values,different oscillation behaviours in PND for even and odd photon numbers appear,respectively.

  6. "Either-or" two-slit interference: stable coherent propagation of individual photons through separate slits.

    Science.gov (United States)

    Alkon, D L

    2001-05-01

    In quantum theory, nothing that is observable, be it physical, chemical, or biological, is separable from the observer. Furthermore, ". all possible knowledge concerning that object is given by its wave function" (Wigner, E. 1967. Symmetries and Reflections. Indiana University Press, Bloomington, IN), which can only describe probabilities of future events. In physical systems, quantum mechanical probabilistic events that are microscopic must, in turn, account for macroscopic events that are associated with a greater degree of certainty. In biological systems, probabilistic statistical mechanical events, such as secretion of microscopic synaptic vesicles, must account for macroscopic postsynaptic potentials; probabilistic single-channel events sum to produce a macroscopic ionic current across a cell membrane; and bleaching of rhodopsin molecules (responsible for quantal potential "bumps") produces a photoreceptor generator potential. Among physical systems, a paradigmatic example of how quantum theory applies to the observation of events concerns the interactions of particles (e.g., photons, electrons) with the two-slit apparatus to generate an interference pattern from a single common light source. For two-slit systems that use two independent laser sources with brief (<1 ms) intervals of mutual coherence (Paul, H. 1986. Rev. Modern Phys. 58:209-231), each photon has been considered to arise from both beams and has a probability amplitude to pass through each of the two slits. Here, a single laser source two-slit interference system was constructed so that each photon has a probability amplitude to pass through only one or the other, but not both slits. Furthermore, all photons passing through one slit could be distinguished from all photons passing through the other slit before their passage. This "either-or" system produced a stable interference pattern indistinguishable from the interference produced when both slits were accessible to each photon. Because this

  7. Strain-optic active control for quantum integrated photonics

    CERN Document Server

    Humphreys, Peter C; Spring, Justin B; Moore, Merritt; Salter, Patrick S; Booth, Martin J; Kolthammer, W Steven; Walmsley, Ian A

    2014-01-01

    We present a practical method for active phase control on a photonic chip that has immediate applications in quantum photonics. Our approach uses strain-optic modification of the refractive index of individual waveguides, effected by a millimeter-scale mechanical actuator. The resulting phase change of propagating optical fields is rapid and polarization-dependent, enabling quantum applications that require active control and polarization encoding. We demonstrate strain-optic control of non-classical states of light in silica, showing the generation of 2-photon polarisation N00N states by manipulating Hong-Ou-Mandel interference. We also demonstrate switching times of a few microseconds, which are sufficient for silica-based feed-forward control of photonic quantum states.

  8. Linear Amplification of Optical Signal in Coupled Photonic Crystal Waveguides

    CERN Document Server

    Jandieri, Vakhtang

    2015-01-01

    We introduce a weakly coupled photonic crystal waveguide as a promising and realistic model for all-optical amplification. A symmetric pillar type coupled photonic crystal waveguide consisting of dielectric rods periodically distributed in a free space is proposed as all-optical amplifier. Using the unique features of the photonic crystals to control and guide the light, we have properly chosen the frequency at which only one mode (odd mode) becomes the propagating mode in the coupled photonic crystal waveguide, whereas another mode (even mode) is completely reflected from the guiding structure. Under this condition, the all-optical amplification is fully realized. The amplification coefficient for the continuous signal and the Gaussian pulse is calculated.

  9. Parametric imaging of viscoelasticity using optical coherence elastography

    Science.gov (United States)

    Wijesinghe, Philip; McLaughlin, Robert A.; Sampson, David D.; Kennedy, Brendan F.

    2015-03-01

    We demonstrate imaging of soft tissue viscoelasticity using optical coherence elastography. Viscoelastic creep deformation is induced in tissue using step-like compressive loading and the resulting time-varying deformation is measured using phase-sensitive optical coherence tomography. From a series of co-located B-scans, we estimate the local strain rate as a function of time, and parameterize it using a four-parameter Kelvin-Voigt model of viscoelastic creep. The estimated viscoelastic strain and time constant are used to visualize viscoelastic creep in 2D, dual-parameter viscoelastograms. We demonstrate our technique on six silicone tissue-simulating phantoms spanning a range of viscoelastic parameters. As an example in soft tissue, we report viscoelastic contrast between muscle and connective tissue in fresh, ex vivo rat gastrocnemius muscle and mouse abdominal transection. Imaging viscoelastic creep deformation has the potential to provide complementary contrast to existing imaging modalities, and may provide greater insight into disease pathology.

  10. Optical Coherence Tomography in Spontaneous Resolution of Vitreomacular Traction Syndrome

    Directory of Open Access Journals (Sweden)

    Kuo-Hsuan Hung

    2010-06-01

    Full Text Available Vitreomacular traction syndrome (VTS is a vitreoretinal interface abnormality. The disorder is caused by incomplete posterior vitreous detachment with persistent traction on the macula that produces symptoms and decreased vision. Most symptomatic eyes with VTS undergo a further decrease in visual acuity. Spontaneous complete vitreomacular separation occurs infrequently in eyes with VTS. Surgical intervention may be considered if severe metamorphopsia and decreased visual quality occur. Herein, we report 2 typical cases of idiopathic VTS with spontaneous resolution of vitreo-retinal traction demonstrated by optical coherence tomography. Optical coherence tomography is a sensitive and useful tool for the confirmation of diagnosis and for the serial anatomical evaluation of patients with VTS.

  11. Control of coherent backscattering by breaking optical reciprocity

    CERN Document Server

    Bromberg, Y; Popoff, S M; Cao, H

    2015-01-01

    Reciprocity is a universal principle that has a profound impact on many areas of physics. A fundamental phenomenon in condensed-matter physics, optical physics and acoustics, arising from reciprocity, is the constructive interference of quantum or classical waves which propagate along time-reversed paths in disordered media, leading to, for example, weak localization and metal-insulator transition. Previous studies have shown that such coherent effects are suppressed when reciprocity is broken. Here we show that by breaking reciprocity in a controlled manner, we can tune, rather than simply suppress, these phenomena. In particular, we manipulate coherent backscattering of light, also known as weak localization. By utilizing a non-reciprocal magneto-optical effect, we control the interference between time-reversed paths inside a multimode fiber with strong mode mixing, and realize a continuous transition from the well-known peak to a dip in the backscattered intensity. Our results may open new possibilities fo...

  12. Optical coherence tomography a clinical and technical update

    CERN Document Server

    Cunha-Vaz, José

    2012-01-01

    Optical Coherence Tomography represents the ultimate noninvasive  ocular imaging technique although being in the field for over two-decades. This book encompasses both medical and technical developments and recent achievements. Here, the authors cover the field of application from the anterior to the posterior ocular segments (Part I) and present a comprehensive review on the development of OCT. Important developments towards  clinical applications are covered in Part II, ranging from the adaptive optics to the integration on a slit-lamp, and passing through new structural  and functional information extraction from OCT data. The book is intended to be informative, coherent and comprehensive for both the medical and technical communities and aims at easing the communication between the two fields and bridging the gap between the two scientific communities.

  13. Imaging cutaneous T-Cell lymphoma with optical coherence tomography

    DEFF Research Database (Denmark)

    Ring, H.C.; Hansen Stamp, I.M.; Jemec, G.B.E.

    2012-01-01

    Aim: To investigate the presentation of a patch-stage cutaneous T-cell lymphoma (CTCL) using optical coherence tomography (OCT). Methods: A patient with a patch caused by CTCL was photographed digitally, OCT-scanned and biopsied. A normal skin area adjacent to the patch was OCT-scanned for compar......Aim: To investigate the presentation of a patch-stage cutaneous T-cell lymphoma (CTCL) using optical coherence tomography (OCT). Methods: A patient with a patch caused by CTCL was photographed digitally, OCT-scanned and biopsied. A normal skin area adjacent to the patch was OCT.......13 mm. A good immediate correlation was found between histology and OCT imaging of the sample. Conclusion: The aetiology of the elongated structures is thought to be lymphomatous infiltrates. Similar findings have been described in ocular lymphoma and may therefore be an important characteristic...

  14. Topology optimization for optical microlithography with partially coherent illumination

    DEFF Research Database (Denmark)

    Zhou, Mingdong; Lazarov, Boyan Stefanov; Sigmund, Ole

    2017-01-01

    This article revisits a topology optimization design approach for micro-manufacturing and extends it to optical microlithography with partially coherent illumination. The solution is based on a combination of two technologies, the topology optimization and the proximity error correction in microl......This article revisits a topology optimization design approach for micro-manufacturing and extends it to optical microlithography with partially coherent illumination. The solution is based on a combination of two technologies, the topology optimization and the proximity error correction...... in microlithography/nanolithography. The key steps include (i) modeling the physical inputs of the fabrication process, including the ultraviolet light illumination source and the mask, as the design variables in optimization and (ii) applying physical filtering and heaviside projection for topology optimization...

  15. Passive thermo-optic feedback for robust athermal photonic systems

    Science.gov (United States)

    Rakich, Peter T.; Watts, Michael R.; Nielson, Gregory N.

    2015-06-23

    Thermal control devices, photonic systems and methods of stabilizing a temperature of a photonic system are provided. A thermal control device thermally coupled to a substrate includes a waveguide for receiving light, an absorption element optically coupled to the waveguide for converting the received light to heat and an optical filter. The optical filter is optically coupled to the waveguide and thermally coupled to the absorption element. An operating point of the optical filter is tuned responsive to the heat from the absorption element. When the operating point is less than a predetermined temperature, the received light is passed to the absorption element via the optical filter. When the operating point is greater than or equal to the predetermined temperature, the received light is transmitted out of the thermal control device via the optical filter, without being passed to the absorption element.

  16. All-optically integrated multimodality imaging system: combined photoacoustic microscopy, optical coherence tomography, and fluorescence imaging

    Science.gov (United States)

    Chen, Zhongjiang; Yang, Sihua; Xing, Da

    2016-10-01

    We have developed a multimodality imaging system by optically integrating all-optical photoacoustic microscopy (AOPAM), optical coherence tomography (OCT) and fluorescence microscopy (FLM) to provide complementary information including optical absorption, optical back-scattering and fluorescence contrast of biological tissue. By sharing the same low-coherence Michelson interferometer, AOPAM and OCT could be organically optically combined to obtain the absorption and scattering information of the biological tissues. Also, owing to using the same laser source and objective lens, intrinsically registered photoacoustic and fluorescence signals are obtained to present the radiative and nonradiative transition process of absorption. Simultaneously photoacoustic angiography, tissue structure and fluorescence molecular in vivo images of mouse ear were acquired to demonstrate the capabilities of the optically integrated trimodality imaging system, which can present more information to study tumor angiogenesis, vasculature, anatomical structure and microenvironments in vivo.

  17. Strong electronic correlation effects in coherent multidimensional nonlinear optical spectroscopy.

    Science.gov (United States)

    Karadimitriou, M E; Kavousanaki, E G; Dani, K M; Fromer, N A; Perakis, I E

    2011-05-12

    We discuss a many-body theory of the coherent ultrafast nonlinear optical response of systems with a strongly correlated electronic ground state that responds unadiabatically to photoexcitation. We introduce a truncation of quantum kinetic density matrix equations of motion that does not rely on an expansion in terms of the interactions and thus applies to strongly correlated systems. For this we expand in terms of the optical field, separate out contributions to the time-evolved many-body state due to correlated and uncorrelated multiple optical transitions, and use "Hubbard operator" density matrices to describe the exact dynamics of the individual contributions within a subspace of strongly coupled states, including "pure dephasing". Our purpose is to develop a quantum mechanical tool capable of exploring how, by coherently photoexciting selected modes, one can trigger nonlinear dynamics of strongly coupled degrees of freedom. Such dynamics could lead to photoinduced phase transitions. We apply our theory to the nonlinear response of a two-dimensional electron gas (2DEG) in a magnetic field. We coherently photoexcite the two lowest Landau level (LL) excitations using three time-delayed optical pulses. We identify some striking temporal and spectral features due to dynamical coupling of the two LLs facilitated by inter-Landau-level magnetoplasmon and magnetoroton excitations and compare to three-pulse four-wave-mixing (FWM) experiments. We show that these features depend sensitively on the dynamics of four-particle correlations between an electron-hole pair and a magnetoplasmon/magnetoroton, reminiscent of exciton-exciton correlations in undoped semiconductors. Our results shed light into unexplored coherent dynamics and relaxation of the quantum Hall system (QHS) and can provide new insight into non-equilibrium co-operative phenomena in strongly correlated systems.

  18. Multifocal cysticercosis with optical coherence tomography findings in a child

    Directory of Open Access Journals (Sweden)

    Manisha Agarwal

    2012-01-01

    Full Text Available We herein report a case with multifocal cysticercosis - sub-conjunctival cysticercus cyst, sub-retinal cysticercosis, and neurocysticercosis in a child. The optical coherence tomography (OCT findings of the sub-retinal cysticercus cyst are reported. He was treated with anti-helminthic drugs and oral prednisolone followed by surgical removal of the sub-retinal cyst. He subsequently underwent silicone oil removal with lens aspiration and intraocular lens implantation maintaining stable vision

  19. Demonstration of Near-Optimal Discrimination of Optical Coherent States

    DEFF Research Database (Denmark)

    Wittmann, Christoffer; Takeoka, Masahiro; Cassemiro, Katiuscia N

    2008-01-01

    The optimal discrimination of nonorthogonal quantum states with minimum error probability is a fundamental task in quantum measurement theory as well as an important primitive in optical communication. In this work, we propose and experimentally realize a new and simple quantum measurement strategy...... capable of discriminating two coherent states with smaller error probabilities than can be obtained using the standard measurement devices: the Kennedy receiver and the homodyne receiver....

  20. Submicron Resolution Spectral-Domain Optical Coherence Tomography

    KAUST Repository

    Alarousu, Erkki

    2013-11-14

    Apparatuses and systems for submicron resolution spectral-domain optical coherence tomography (OCT) are disclosed. The system may use white light sources having wavelengths within 400-1000 nanometers, and achieve resolution below 1 .mu.m. The apparatus is aggregated into a unitary piece, and a user can connect the apparatus to a user provided controller and/or light source. The light source may be a supercontinuum source.