WorldWideScience

Sample records for coefficient hyperpolarized 3he-mri

  1. Validity of apparent diffusion coefficient hyperpolarized 3He-MRI using MSCT and pulmonary function tests as references

    DEFF Research Database (Denmark)

    Diaz, Sandra; Casselbrant, Ingrid; Piitulainen, Eeva

    2008-01-01

    PURPOSE: To compare apparent diffusion coefficient (ADC) measurements from hyperpolarized (HP) helium ((3)He)-magnetic resonance imaging (MRI) with quantitative data from multislice Computed Tomography (CT) (MSCT) of the whole lungs and pulmonary function tests (PFT). MATERIALS AND METHODS: Twenty......-seven subjects, 22 with established emphysema and 5 with preclinical emphysema defined by PFT criteria, were examined with HP (3)He-MRI and MSCT. Mean age was 55 (+/-12) years, 18 female and 9 male. Mean ADC from (3)He-MRI was compared with emphysema index (EI), 15th percentile and mean lung density (MLD) values...... from MSCT. Both mean ADC and MSCT data were compared to PFT, especially percent of predicted diffusing capacity of carbon monoxide (%predicted DLCO), using Pearson's correlation test. RESULTS: Mean ADC and standard deviation values were 0.392+/-0.119 cm(2)/s for the established emphysema group and 0...

  2. Hyperpolarized 3He apparent diffusion coefficient MRI of the lung: reproducibility and volume dependency in healthy volunteers and patients with emphysema

    DEFF Research Database (Denmark)

    Diaz, S.; Casselbrant, I.; Piitulainen, E.

    2008-01-01

    PURPOSE: To measure the apparent diffusion coefficient (ADC) of hyperpolarized (HP) (3)He gas using diffusion weighted MRI in healthy volunteers and patients with emphysema and examine the reproducibility and volume dependency. MATERIALS AND METHODS: A total of eight healthy volunteers and 16...... patients with emphysema were examined after inhalation of HP (3)He gas mixed with nitrogen (N(2)) during breathhold starting from functional residual capacity (FRC) in supine position. Coronal diffusion-sensitized MR images were acquired. Each subject was imaged on three separate days over a seven...... in mean ADC with increased inhaled gas volume was observed in both groups. CONCLUSION: Mean ADC and SD of HP (3)He MRI is reproducible and discriminates well between healthy controls and patients with emphysema at the higher gas volume. This method is robust and may be useful to gain new insights...

  3. Hyperpolarized 3He magnetic resonance imaging: Preliminary evaluation of phenotyping potential in chronic obstructive pulmonary disease

    International Nuclear Information System (INIS)

    Mathew, Lindsay; Kirby, Miranda; Etemad-Rezai, Roya; Wheatley, Andrew; McCormack, David G.; Parraga, Grace

    2011-01-01

    Rationale and objectives: Emphysema and small airway obstruction are the pathological hallmarks of chronic obstructive pulmonary disease (COPD). The aim of this pilot study in a small group of chronic obstructive pulmonary disease (COPD) patients was to quantify hyperpolarized helium-3 ( 3 He) magnetic resonance imaging (MRI) functional and structural measurements and to explore the potential role for 3 He MRI in detecting the lung structural and functional COPD phenotypes. Materials and methods: We evaluated 20 ex-smokers with stage I (n = 1), stage II (n = 9) and stage III COPD (n = 10). All subjects underwent same-day plethysmography, spirometry, 1 H MRI and hyperpolarized 3 He MRI at 3.0 T. 3 He ventilation defect percent (VDP) was generated from 3 He static ventilation images and 1 H thoracic images and the 3 He apparent diffusion coefficient (ADC) was derived from diffusion-weighted MRI. Results: Based on the relative contribution of normalized ADC and VDP, there was evidence of a predominant 3 He MRI measurement in seven patients (n = 3 mainly ventilation defects or VDP dominant (VD), n = 4 mainly increased ADC or ADC dominant (AD)). Analysis of variance (ANOVA) showed significantly lower ADC for subjects with predominantly elevated VDP (p = 0.02 compared to subjects with predominantly elevated ADC; p = 0.008 compared to mixed group) and significantly decreased VDP for subjects with predominantly elevated ADC (p = 0.003, compared to mixed group). Conclusion: In this small pilot study, a preliminary analysis shows the potential for 3 He MRI to categorize or phenotype COPD ex-smokers, providing good evidence of feasibility for larger prospective studies.

  4. Hyperpolarized {sup 3}He magnetic resonance imaging: Preliminary evaluation of phenotyping potential in chronic obstructive pulmonary disease

    Energy Technology Data Exchange (ETDEWEB)

    Mathew, Lindsay, E-mail: lmathew@imaging.robarts.ca [Imaging Research Laboratories, Robarts Research Institute, London (Canada); Department of Medical Biophysics, University of Western Ontario, London (Canada); Kirby, Miranda, E-mail: mkirby@imaging.robarts.ca [Imaging Research Laboratories, Robarts Research Institute, London (Canada); Department of Medical Biophysics, University of Western Ontario, London (Canada); Etemad-Rezai, Roya, E-mail: Roya.EtemadRezai@lhsc.on.ca [Department of Medical Imaging, University of Western Ontario (Canada); Wheatley, Andrew, E-mail: awheat@imaging.robarts.ca [Imaging Research Laboratories, Robarts Research Institute, London (Canada); McCormack, David G., E-mail: David.McCormack@lhsc.on.ca [Imaging Research Laboratories, Robarts Research Institute, London (Canada); Division of Respirology, Department of Medicine, University of Western Ontario, London (Canada); Lawson Health Research Institute, London (Canada); Parraga, Grace, E-mail: gep@imaging.robarts.ca [Imaging Research Laboratories, Robarts Research Institute, London (Canada); Department of Medical Biophysics, University of Western Ontario, London (Canada); Department of Medical Imaging, University of Western Ontario (Canada); Lawson Health Research Institute, London (Canada)

    2011-07-15

    Rationale and objectives: Emphysema and small airway obstruction are the pathological hallmarks of chronic obstructive pulmonary disease (COPD). The aim of this pilot study in a small group of chronic obstructive pulmonary disease (COPD) patients was to quantify hyperpolarized helium-3 ({sup 3}He) magnetic resonance imaging (MRI) functional and structural measurements and to explore the potential role for {sup 3}He MRI in detecting the lung structural and functional COPD phenotypes. Materials and methods: We evaluated 20 ex-smokers with stage I (n = 1), stage II (n = 9) and stage III COPD (n = 10). All subjects underwent same-day plethysmography, spirometry, {sup 1}H MRI and hyperpolarized {sup 3}He MRI at 3.0 T. {sup 3}He ventilation defect percent (VDP) was generated from {sup 3}He static ventilation images and {sup 1}H thoracic images and the {sup 3}He apparent diffusion coefficient (ADC) was derived from diffusion-weighted MRI. Results: Based on the relative contribution of normalized ADC and VDP, there was evidence of a predominant {sup 3}He MRI measurement in seven patients (n = 3 mainly ventilation defects or VDP dominant (VD), n = 4 mainly increased ADC or ADC dominant (AD)). Analysis of variance (ANOVA) showed significantly lower ADC for subjects with predominantly elevated VDP (p = 0.02 compared to subjects with predominantly elevated ADC; p = 0.008 compared to mixed group) and significantly decreased VDP for subjects with predominantly elevated ADC (p = 0.003, compared to mixed group). Conclusion: In this small pilot study, a preliminary analysis shows the potential for {sup 3}He MRI to categorize or phenotype COPD ex-smokers, providing good evidence of feasibility for larger prospective studies.

  5. Progression of Emphysema Evaluated by MRI Using Hyperpolarized 3He (HP 3He Measurements in Patients with Alpha-1-Antitrypsin (A1AT) Deficiency Compared with CT and Lung Function Tests

    International Nuclear Information System (INIS)

    Stavngaard, T.; Vejby Soegaard, L.; Batz, M.; Schreiber, L.M.; Dirksen, A.

    2009-01-01

    Background: The progression of emphysema is traditionally measured by pulmonary function test, with forced expiratory volume in 1 s (FEV1) being the most accepted and used measurement. However, FEV1 is insensitive in detecting mild/slow progression of emphysema because of low reproducibility as compared to yearly decline. Purpose: To investigate the progression of emphysema over a period of 2 years using diffusion-weighted hyperpolarized (HP) 3 He magnetic resonance imaging (MRI) in patients with alpha-1-antitrypsin (A1AT) deficiency. Material and Methods: Nine patients with severe A1AT deficiency were studied over a period of 2 years (baseline, year 1, and year 2) with HP 3 He MRI using apparent diffusion coefficient (ADC), lung function tests (FEV1 and carbon monoxide lung diffusion capacity [DL,CO]), and computed tomography (CT) using densitometric parameters (15th percentile density [CT-PD15] and relative area of emphysema below -910 HU [CT-RA-910]). Results: Seven patients were scanned three times, one patient two times, and one patient only at baseline. The mean increase in ADC values from first to last HP 3 He MR scanning was 3.8% (0.014 cm 2 /s [SD 0.024 cm 2 /s]; not significant). The time trends for FEV1, DL,CO, CT-PD15, and CT-RA-910 were all statistically significant. We found a high correlation between ADC and DL,CO (P 3 He MRI for monitoring the progression of emphysema. However, in the future, larger studies are needed to confirm these preliminary results

  6. An image acquisition and registration strategy for the fusion of hyperpolarized helium-3 MRI and x-ray CT images of the lung

    International Nuclear Information System (INIS)

    Ireland, Rob H; Woodhouse, Neil; Hoggard, Nigel; Swinscoe, James A; Foran, Bernadette H; Hatton, Matthew Q; Wild, Jim M

    2008-01-01

    The purpose of this ethics committee approved prospective study was to evaluate an image acquisition and registration protocol for hyperpolarized helium-3 magnetic resonance imaging ( 3 He-MRI) and x-ray computed tomography. Nine patients with non-small cell lung cancer (NSCLC) gave written informed consent to undergo a free-breathing CT, an inspiration breath-hold CT and a 3D ventilation 3 He-MRI in CT position using an elliptical birdcage radiofrequency (RF) body coil. 3 He-MRI to CT image fusion was performed using a rigid registration algorithm which was assessed by two observers using anatomical landmarks and a percentage volume overlap coefficient. Registration of 3 He-MRI to breath-hold CT was more accurate than to free-breathing CT; overlap 82.9 ± 4.2% versus 59.8 ± 9.0% (p 3 He-MRI and CT to be acquired with similar breath holds and body position through the use of a birdcage 3 He-MRI body RF coil and an inspiration breath-hold CT. Fusion of 3 He-MRI to CT may be useful for the assessment of patients with lung diseases.

  7. An image acquisition and registration strategy for the fusion of hyperpolarized helium-3 MRI and x-ray CT images of the lung

    Science.gov (United States)

    Ireland, Rob H.; Woodhouse, Neil; Hoggard, Nigel; Swinscoe, James A.; Foran, Bernadette H.; Hatton, Matthew Q.; Wild, Jim M.

    2008-11-01

    The purpose of this ethics committee approved prospective study was to evaluate an image acquisition and registration protocol for hyperpolarized helium-3 magnetic resonance imaging (3He-MRI) and x-ray computed tomography. Nine patients with non-small cell lung cancer (NSCLC) gave written informed consent to undergo a free-breathing CT, an inspiration breath-hold CT and a 3D ventilation 3He-MRI in CT position using an elliptical birdcage radiofrequency (RF) body coil. 3He-MRI to CT image fusion was performed using a rigid registration algorithm which was assessed by two observers using anatomical landmarks and a percentage volume overlap coefficient. Registration of 3He-MRI to breath-hold CT was more accurate than to free-breathing CT; overlap 82.9 ± 4.2% versus 59.8 ± 9.0% (p < 0.001) and mean landmark error 0.75 ± 0.24 cm versus 1.25 ± 0.60 cm (p = 0.002). Image registration is significantly improved by using an imaging protocol that enables both 3He-MRI and CT to be acquired with similar breath holds and body position through the use of a birdcage 3He-MRI body RF coil and an inspiration breath-hold CT. Fusion of 3He-MRI to CT may be useful for the assessment of patients with lung diseases.

  8. Hyperpolarized 3He MRI and 81mKr SPECT in chronic obstructive pulmonary disease

    DEFF Research Database (Denmark)

    Stavngaard, Trine; Søgaard, Lise; Mortensen, J

    2005-01-01

    visual defect score (r=0.80, pemphysema (pulmonary function test and HRCT). The defect scores were largest on 81mKr SPECT (the score on HP 3He MRI...... was to compare ventilation imaging methods in 26 patients with chronic obstructive pulmonary disease (COPD) and nine lung healthy volunteers. METHODS: HP 3He MRI, 81mKr single-photon emission computed tomography (SPECT), high-resolution computed tomography (HRCT) and pulmonary function tests were performed....... The three scans were scored visually as percentage of non-ventilated/diseased lung, and a computer-based objective measure of the ventilated volume in HP 3He MRI and 81mKr SPECT and an emphysema index in HRCT were calculated. RESULTS: We found a good correlation between HP 3He MRI and 81mKr SPECT for both...

  9. WE-AB-202-07: Ventilation CT: Voxel-Level Comparison with Hyperpolarized Helium-3 & Xenon-129 MRI

    Energy Technology Data Exchange (ETDEWEB)

    Tahir, B; Marshall, H; Hughes, P; Stewart, N; Horn, F; Collier, G; Norquay, G; Hart, K; Swinscoe, J; Hatton, M; Wild, J; Ireland, R [University of Sheffield, Sheffield (United Kingdom)

    2016-06-15

    Purpose: To compare the spatial correlation of ventilation surrogates computed from inspiratory and expiratory breath-hold CT with hyperpolarized Helium-3 & Xenon-129 MRI in a cohort of lung cancer patients. Methods: 5 patients underwent expiration & inspiration breath-hold CT. Xenon-129 & {sup 1}H MRI were also acquired at the same inflation state as inspiratory CT. This was followed immediately by acquisition of Helium-3 & {sup 1}H MRI in the same breath and at the same inflation state as inspiratory CT. Expiration CT was deformably registered to inspiration CT for calculation of ventilation CT from voxel-wise differences in Hounsfield units. Inspiration CT and the Xenon-129’s corresponding anatomical {sup 1}H MRI were registered to Helium-3 MRI via the same-breath anatomical {sup 1}H MRI. This enabled direct comparison of CT ventilation with Helium-3 MRI & Xenon-129 MRI for the median values in corresponding regions of interest, ranging from finer to coarser in-plane dimensions of 10 by 10, 20 by 20, 30 by 30 and 40 by 40, located within the lungs as defined by the same-breath {sup 1}H MRI lung mask. Spearman coefficients were used to assess voxel-level correlation. Results: The median Spearman’s coefficients of ventilation CT with Helium-3 & Xenon-129 MRI for ROIs of 10 by 10, 20 by 20, 30 by 30 and 40 by 40 were 0.52, 0.56, 0.60 and 0.68 and 0.40, 0.42, 0.52 and 0.70, respectively. Conclusion: This work demonstrates a method of acquiring CT & hyperpolarized gas MRI (Helium-3 & Xenon-129 MRI) in similar breath-holds to enable direct spatial comparison of ventilation maps. Initial results show moderate correlation between ventilation CT & hyperpolarized gas MRI, improving for coarser regions which could be attributable to the inherent noise in CT intensity, non-ventilatory effects and registration errors at the voxel-level. Thus, it may be more beneficial to quantify ventilation at a more regional level.

  10. Progression of emphysema evaluated by MRI using hyperpolarized (3)He (HP (3)He) measurements in patients with alpha-1-antitrypsin (A1AT) deficiency compared with CT and lung function tests

    DEFF Research Database (Denmark)

    Stavngaard, T; Søgaard, L Vejby; Batz, M

    2009-01-01

    BACKGROUND: The progression of emphysema is traditionally measured by pulmonary function test, with forced expiratory volume in 1 s (FEV(1)) being the most accepted and used measurement. However, FEV(1) is insensitive in detecting mild/slow progression of emphysema because of low reproducibility...... as compared to yearly decline. PURPOSE: To investigate the progression of emphysema over a period of 2 years using diffusion-weighted hyperpolarized (HP) (3)He magnetic resonance imaging (MRI) in patients with alpha-1-antitrypsin (A1AT) deficiency. MATERIAL AND METHODS: Nine patients with severe A1AT...... density [CT-PD15] and relative area of emphysema below -910 HU [CT-RA-910]). RESULTS: Seven patients were scanned three times, one patient two times, and one patient only at baseline. The mean increase in ADC values from first to last HP (3)He MR scanning was 3.8% (0.014 cm(2)/s [SD 0.024 cm(2)/s...

  11. Assessment of lung disease in children with cystic fibrosis using hyperpolarized 3-Helium MRI: comparison with Shwachman score, Chrispin-Norman score and spirometry

    International Nuclear Information System (INIS)

    Beek, Edwin J.R. van; Hill, Catherine; Woodhouse, Neil; Fichele, Stanislao; Fleming, Sally; Wild, Jim M.; Howe, Bridget; Bott, Sandra; Taylor, Christopher J.

    2007-01-01

    This study assesses the feasibility of hyperpolarized 3-Helium MRI in children with cystic fibrosis (CF) and correlates the findings with standard clinical parameters based on chest radiograph (CXR) and pulmonary function tests (PFT). An uncontrolled, observational study in eighteen children with cystic fibrosis aged 5 - 17 years (median 12.1 years), with different severity of disease was carried out. All subjects underwent routine clinical assessment including PFT and standard auxology; CXR was obtained and Shwachman and Chrispin-Norman scores calculated. Hyperpolarized 3-He magnetic resonance imaging (MRI) was carried out using a spin-exchange polarizer and a whole body 1.5 T scanner. Ventilation distribution images were obtained during a 21-second breath-hold and scored according to previously defined criteria. Spearman's non-parametric correlations test was performed to assess for statistical significance at the p<0.05 level. The children tolerated the procedure well. No desaturation events were observed during 3-He MRI. A significant, albeit moderate, correlation was found between MRI score and FEV1% predicted (r=-0.41; p=0.047) and FVC% predicted (r=-0.42; p=0.04), while there were trends of correlations between Shwachman score and MRI score (r=-0.38; p=0.06) and Shwachman score and FEV1% predicted (r=0.39; p=0.055). The feasibility of hyperpolarized 3-He MRI in children with CF was demonstrated. MRI appears to be able to demonstrate functional lung changes, although correlations with routine clinical tests are only moderate to poor. This non-ionising radiation technique could be useful for monitoring lung disease and assessing therapy in this patient population. (orig.)

  12. Assessment of lung disease in children with cystic fibrosis using hyperpolarized 3-Helium MRI: comparison with Shwachman score, Chrispin-Norman score and spirometry

    Energy Technology Data Exchange (ETDEWEB)

    Beek, Edwin J.R. van [University of Sheffield, Unit of Academic Radiology, Sheffield (United Kingdom); University of Iowa, Department of Radiology, Carver College of Medicine, Iowa City (United States); University of Iowa, Department of Radiology, Iowa City, IA (United States); Hill, Catherine; Woodhouse, Neil; Fichele, Stanislao; Fleming, Sally; Wild, Jim M. [University of Sheffield, Unit of Academic Radiology, Sheffield (United Kingdom); Howe, Bridget; Bott, Sandra; Taylor, Christopher J. [University of Sheffield, Academic Unit of Child Health, Sheffield (United Kingdom)

    2007-04-15

    This study assesses the feasibility of hyperpolarized 3-Helium MRI in children with cystic fibrosis (CF) and correlates the findings with standard clinical parameters based on chest radiograph (CXR) and pulmonary function tests (PFT). An uncontrolled, observational study in eighteen children with cystic fibrosis aged 5 - 17 years (median 12.1 years), with different severity of disease was carried out. All subjects underwent routine clinical assessment including PFT and standard auxology; CXR was obtained and Shwachman and Chrispin-Norman scores calculated. Hyperpolarized 3-He magnetic resonance imaging (MRI) was carried out using a spin-exchange polarizer and a whole body 1.5 T scanner. Ventilation distribution images were obtained during a 21-second breath-hold and scored according to previously defined criteria. Spearman's non-parametric correlations test was performed to assess for statistical significance at the p<0.05 level. The children tolerated the procedure well. No desaturation events were observed during 3-He MRI. A significant, albeit moderate, correlation was found between MRI score and FEV1% predicted (r=-0.41; p=0.047) and FVC% predicted (r=-0.42; p=0.04), while there were trends of correlations between Shwachman score and MRI score (r=-0.38; p=0.06) and Shwachman score and FEV1% predicted (r=0.39; p=0.055). The feasibility of hyperpolarized 3-He MRI in children with CF was demonstrated. MRI appears to be able to demonstrate functional lung changes, although correlations with routine clinical tests are only moderate to poor. This non-ionising radiation technique could be useful for monitoring lung disease and assessing therapy in this patient population. (orig.)

  13. Quantitative 1H and hyperpolarized 3He magnetic resonance imaging: Comparison in chronic obstructive pulmonary disease and healthy never-smokers

    International Nuclear Information System (INIS)

    Owrangi, Amir M.; Wang, Jian X.; Wheatley, Andrew; McCormack, David G.; Parraga, Grace

    2014-01-01

    Objective: The aim of this study was to quantitatively evaluate the relationship between short echo time pulmonary 1 H magnetic resonance imaging (MRI) signal intensity (SI) and 3 He MRI apparent diffusion coefficients (ADC), high-resolution computed tomography (CT) measurements of emphysema, and pulmonary function measurements. Materials and methods: Nine healthy never-smokers and 11 COPD subjects underwent same-day plethysmography, spirometry, short echo time ((TE) = 1.2 ms) 1 H and diffusion-weighted hyperpolarized 3 He MRI (b = 1.6 s/cm 2 ) at 3.0 T. In addition, for COPD subjects only, CT densitometry was also performed. Results: Mean 1 H SI was significantly greater for never-smokers (12.1 ± 1.1 arbitrary units (AU)) compared to COPD subjects (10.9 ± 1.3 AU, p = 0.04). The 1 H SI AP-gradient was also significantly greater for never-smokers (0.40 AU/cm, R 2 = 0.94) compared to COPD subjects (0.29 AU/cm, R 2 = 0.968, p = 0.05). There was a significant correlation between 1 H SI and 3 He ADC (r = −0.58, p = 0.008) and significant correlations between 1 H MR SI and CT measurements of emphysema (RA 950 , r = −0.69, p = 0.02 and HU 15 , r = 0.66, p = 0.03). Conclusions: The significant and moderately strong relationship between 1 H SI and 3 He ADC, as well as between 1 H SI and CT measurements of emphysema suggests that these imaging methods and measurements may be quantifying similar tissue changes in COPD and that pulmonary 1 H SI may be used to monitor emphysema as a complement to CT and noble gas MRI

  14. Validity of apparent diffusion coefficient hyperpolarized 3He-MRI using MSCT and pulmonary function tests as references

    DEFF Research Database (Denmark)

    Diaz, Sandra; Casselbrant, Ingrid; Piitulainen, Eeva

    2008-01-01

    from MSCT. Both mean ADC and MSCT data were compared to PFT, especially percent of predicted diffusing capacity of carbon monoxide (%predicted DLCO), using Pearson's correlation test. RESULTS: Mean ADC and standard deviation values were 0.392+/-0.119 cm(2)/s for the established emphysema group and 0....... Correlations between mean ADC and EI and 15th percentile were both r=0.90 and for MLD r=0.59. There was higher correlation between mean ADC and %predicted DLCO (r=0.90) than between EI and %predicted DLCO (r=0.76). CONCLUSION: HP (3)He-MRI correlates well with density measurements from MSCT and agrees better...

  15. Quantitative {sup 1}H and hyperpolarized {sup 3}He magnetic resonance imaging: Comparison in chronic obstructive pulmonary disease and healthy never-smokers

    Energy Technology Data Exchange (ETDEWEB)

    Owrangi, Amir M., E-mail: aowrangi@robats.ca [Imaging Research Laboratories, Robarts Research Institute, 100 Perth Drive, London, Canada N6A 5K8 (Canada); Graduate Program in Biomedical Engineering, The University of Western Ontario, London (Canada); Wang, Jian X., E-mail: jxwang@robats.ca [Imaging Research Laboratories, Robarts Research Institute, 100 Perth Drive, London, Canada N6A 5K8 (Canada); Applied Science Laboratories, General Electric Healthcare (Canada); Wheatley, Andrew, E-mail: awheat@imaging.robarts.ca [Imaging Research Laboratories, Robarts Research Institute, 100 Perth Drive, London, Canada N6A 5K8 (Canada); McCormack, David G., E-mail: David.Mccormack@lhsc.on.ca [Imaging Research Laboratories, Robarts Research Institute, 100 Perth Drive, London, Canada N6A 5K8 (Canada); Division of Respirology, Department of Medicine, The University of Western Ontario, London (Canada); Parraga, Grace, E-mail: gparraga@robats.ca [Imaging Research Laboratories, Robarts Research Institute, 100 Perth Drive, London, Canada N6A 5K8 (Canada); Graduate Program in Biomedical Engineering, The University of Western Ontario, London (Canada); Department of Medical Imaging, The University of Western Ontario, London (Canada); Department of Medical Biophysics, The University of Western Ontario, London (Canada)

    2014-01-15

    Objective: The aim of this study was to quantitatively evaluate the relationship between short echo time pulmonary {sup 1}H magnetic resonance imaging (MRI) signal intensity (SI) and {sup 3}He MRI apparent diffusion coefficients (ADC), high-resolution computed tomography (CT) measurements of emphysema, and pulmonary function measurements. Materials and methods: Nine healthy never-smokers and 11 COPD subjects underwent same-day plethysmography, spirometry, short echo time ((TE) = 1.2 ms) {sup 1}H and diffusion-weighted hyperpolarized {sup 3}He MRI (b = 1.6 s/cm{sup 2}) at 3.0 T. In addition, for COPD subjects only, CT densitometry was also performed. Results: Mean {sup 1}H SI was significantly greater for never-smokers (12.1 ± 1.1 arbitrary units (AU)) compared to COPD subjects (10.9 ± 1.3 AU, p = 0.04). The {sup 1}H SI AP-gradient was also significantly greater for never-smokers (0.40 AU/cm, R{sup 2} = 0.94) compared to COPD subjects (0.29 AU/cm, R{sup 2} = 0.968, p = 0.05). There was a significant correlation between {sup 1}H SI and {sup 3}He ADC (r = −0.58, p = 0.008) and significant correlations between {sup 1}H MR SI and CT measurements of emphysema (RA{sub 950}, r = −0.69, p = 0.02 and HU{sub 15}, r = 0.66, p = 0.03). Conclusions: The significant and moderately strong relationship between {sup 1}H SI and {sup 3}He ADC, as well as between {sup 1}H SI and CT measurements of emphysema suggests that these imaging methods and measurements may be quantifying similar tissue changes in COPD and that pulmonary {sup 1}H SI may be used to monitor emphysema as a complement to CT and noble gas MRI.

  16. Progression of emphysema in a 12-month hyperpolarized 3He-MRI study: lacunarity analysis provided a more sensitive measure than standard ADC analysis

    DEFF Research Database (Denmark)

    Diaz, Sandra; Casselbrant, Ingrid; Piitulainen, Eeva

    2009-01-01

    RATIONALE AND OBJECTIVES: Inhaled hyperpolarized (3)He magnetic resonance (MR) imaging has been used to measure alveolar size in patients with emphysema. The aim of this study was to test the hypothesis that (3)He MR images could be used to develop a biomarker of emphysema progression. MATERIALS...... AND METHODS: Twelve healthy controls and 18 patients with emphysema (eight current smokers, 10 ex-smokers) were imaged at baseline and 6 and 12 months. An additional nine subjects with alpha-1 antitrypsin deficiency (four with emphysema, six without symptoms) were also imaged at baseline and at 6 months. Each...... subject was imaged at two lung volumes: functional residual capacity (FRC) and FRC plus 15% of total lung capacity. Means and standard deviations of apparent diffusion coefficients (ADCs) were calculated from coronal images of the entire lung and correlated with pulmonary function test results...

  17. Phase-contrast MRI and CFD modeling of apparent 3He gas flow in rat pulmonary airways

    Science.gov (United States)

    Minard, Kevin R.; Kuprat, Andrew P.; Kabilan, Senthil; Jacob, Richard E.; Einstein, Daniel R.; Carson, James P.; Corley, Richard A.

    2012-08-01

    Phase-contrast (PC) magnetic resonance imaging (MRI) with hyperpolarized 3He is potentially useful for developing and testing patient-specific models of pulmonary airflow. One challenge, however, is that PC-MRI provides apparent values of local 3He velocity that not only depend on actual airflow but also on gas diffusion. This not only blurs laminar flow patterns in narrow airways but also introduces anomalous airflow structure that reflects gas-wall interactions. Here, both effects are predicted in a live rat using computational fluid dynamics (CFD), and for the first time, simulated patterns of apparent 3He gas velocity are compared with in vivo PC-MRI. Results show (1) that correlations (R2) between measured and simulated airflow patterns increase from 0.23 to 0.79 simply by accounting for apparent 3He transport, and (2) that remaining differences are mainly due to uncertain airway segmentation and partial volume effects stemming from relatively coarse MRI resolution. Higher-fidelity testing of pulmonary airflow predictions should therefore be possible with future imaging improvements.

  18. Hyperpolarized 3helium magnetic resonance ventilation imaging of the lung in cystic fibrosis: comparison with high resolution CT and spirometry

    International Nuclear Information System (INIS)

    McMahon, Colm J.; Dodd, Jonathan D.; Skehan, Stephen J.; Masterson, James B.; Hill, Catherine; Woodhouse, Neil; Wild, Jim M.; Fichele, Stan; Gallagher, Charles G.; Beek, Edwin J.R. van

    2006-01-01

    The purpose of this study was to compare hyperpolarized 3 helium magnetic resonance imaging ( 3 He MRI) of the lungs in adults with cystic fibrosis (CF) with high-resolution computed tomography (HRCT) and spirometry. Eight patients with stable CF prospectively underwent 3 He MRI, HRCT, and spirometry within 1 week. Three-dimensional (3D) gradient-echo sequence was used during an 18-s breath-hold following inhalation of hyperpolarized 3 He. Each lung was divided into six zones; 3 He MRI was scored as percentage ventilation per lung zone. HRCT was scored using a modified Bhalla scoring system. Univariate (Spearman rank) and multivariate correlations were performed between 3 He MRI, HRCT, and spirometry. Results are expressed as mean±SD (range). Spirometry is expressed as percent predicted. There were four men and four women, mean age=31.9±9 (20-46). Mean forced expiratory volume in 1 s (FEV) 1 =52%±29 (27-93). Mean 3 He MRI score=74%±25 (55-100). Mean HRCT score=48.8±24 (13.5-83). The correlation between 3 He MRI and HRCT was strong (R=±0.89, p 3 He MRI; 3 He MRI correlated better with FEV 1 and forced vital capacity (FVC) (R=0.86 and 0.93, p 3 He MRI correlates strongly with structural HRCT abnormalities and is a stronger correlate of spirometry than HRCT in CF. (orig.)

  19. Hyperpolarized 129Xe MRI: A viable functional lung imaging modality?

    International Nuclear Information System (INIS)

    Patz, Samuel; Hersman, F. William; Muradian, Iga; Hrovat, Mirko I.; Ruset, Iulian C.; Ketel, Stephen; Jacobson, Francine; Topulos, George P.; Hatabu, Hiroto; Butler, James P.

    2007-01-01

    The majority of researchers investigating hyperpolarized gas MRI as a candidate functional lung imaging modality have used 3 He as their imaging agent of choice rather than 129 Xe. This preference has been predominantly due to, 3 He providing stronger signals due to higher levels of polarization and higher gyromagnetic ratio, as well as its being easily available to more researchers due to availability of polarizers (USA) or ease of gas transport (Europe). Most researchers agree, however, that hyperpolarized 129 Xe will ultimately emerge as the imaging agent of choice due to its unlimited supply in nature and its falling cost. Our recent polarizer technology delivers vast improvements in hyperpolarized 129 Xe output. Using this polarizer, we have demonstrated the unique property of xenon to measure alveolar surface area noninvasively. In this article, we describe our human protocols and their safety, and our results for the measurement of the partial pressure of pulmonary oxygen (pO 2 ) by observation of 129 Xe signal decay. We note that the measurement of pO 2 by observation of 129 Xe signal decay is more complex than that for 3 He because of an additional signal loss mechanism due to interphase diffusion of 129 Xe from alveolar gas spaces to septal tissue. This results in measurements of an equivalent pO 2 that accounts for both traditional T 1 decay from pO 2 and that from interphase diffusion. We also provide an update on new technological advancements that form the foundation for an improved compact design polarizer as well as improvements that provide another order-of-magnitude scale-up in xenon polarizer output

  20. Hyperpolarized {sup 3}helium magnetic resonance ventilation imaging of the lung in cystic fibrosis: comparison with high resolution CT and spirometry

    Energy Technology Data Exchange (ETDEWEB)

    McMahon, Colm J.; Dodd, Jonathan D.; Skehan, Stephen J.; Masterson, James B. [St. Vincent' s University Hospital, Department of Radiology, Dublin (Ireland); Hill, Catherine; Woodhouse, Neil; Wild, Jim M.; Fichele, Stan [Royal Hallamshire Hospital, The Unit of Academic Radiology, University of Sheffield, Sheffield (United Kingdom); Gallagher, Charles G. [St. Vincent' s University Hospital, Department of National Referral Centre for Adult Cystic Fibrosis, Dublin (Ireland); Beek, Edwin J.R. van [Royal Hallamshire Hospital, The Unit of Academic Radiology, University of Sheffield, Sheffield (United Kingdom); University of Iowa, Department of Radiology, Carver College of Medicine, Iowa City, IA (United States)

    2006-11-15

    The purpose of this study was to compare hyperpolarized {sup 3}helium magnetic resonance imaging ({sup 3}He MRI) of the lungs in adults with cystic fibrosis (CF) with high-resolution computed tomography (HRCT) and spirometry. Eight patients with stable CF prospectively underwent {sup 3}He MRI, HRCT, and spirometry within 1 week. Three-dimensional (3D) gradient-echo sequence was used during an 18-s breath-hold following inhalation of hyperpolarized {sup 3}He. Each lung was divided into six zones; {sup 3}He MRI was scored as percentage ventilation per lung zone. HRCT was scored using a modified Bhalla scoring system. Univariate (Spearman rank) and multivariate correlations were performed between {sup 3}He MRI, HRCT, and spirometry. Results are expressed as mean{+-}SD (range). Spirometry is expressed as percent predicted. There were four men and four women, mean age=31.9{+-}9 (20-46). Mean forced expiratory volume in 1 s (FEV){sub 1}=52%{+-}29 (27-93). Mean {sup 3}He MRI score=74%{+-}25 (55-100). Mean HRCT score=48.8{+-}24 (13.5-83). The correlation between {sup 3}He MRI and HRCT was strong (R={+-}0.89, p<0.001). Bronchiectasis was the only independent predictor of {sup 3}He MRI; {sup 3}He MRI correlated better with FEV{sub 1} and forced vital capacity (FVC) (R=0.86 and 0.93, p<0.01, respectively) than HRCT (R={+-}0.72 and {+-}0.81, p<0.05, respectively). This study showed that {sup 3}He MRI correlates strongly with structural HRCT abnormalities and is a stronger correlate of spirometry than HRCT in CF. (orig.)

  1. Regional alveolar partial pressure of oxygen measurement with parallel accelerated hyperpolarized gas MRI.

    Science.gov (United States)

    Kadlecek, Stephen; Hamedani, Hooman; Xu, Yinan; Emami, Kiarash; Xin, Yi; Ishii, Masaru; Rizi, Rahim

    2013-10-01

    Alveolar oxygen tension (Pao2) is sensitive to the interplay between local ventilation, perfusion, and alveolar-capillary membrane permeability, and thus reflects physiologic heterogeneity of healthy and diseased lung function. Several hyperpolarized helium ((3)He) magnetic resonance imaging (MRI)-based Pao2 mapping techniques have been reported, and considerable effort has gone toward reducing Pao2 measurement error. We present a new Pao2 imaging scheme, using parallel accelerated MRI, which significantly reduces measurement error. The proposed Pao2 mapping scheme was computer-simulated and was tested on both phantoms and five human subjects. Where possible, correspondence between actual local oxygen concentration and derived values was assessed for both bias (deviation from the true mean) and imaging artifact (deviation from the true spatial distribution). Phantom experiments demonstrated a significantly reduced coefficient of variation using the accelerated scheme. Simulation results support this observation and predict that correspondence between the true spatial distribution and the derived map is always superior using the accelerated scheme, although the improvement becomes less significant as the signal-to-noise ratio increases. Paired measurements in the human subjects, comparing accelerated and fully sampled schemes, show a reduced Pao2 distribution width for 41 of 46 slices. In contrast to proton MRI, acceleration of hyperpolarized imaging has no signal-to-noise penalty; its use in Pao2 measurement is therefore always beneficial. Comparison of multiple schemes shows that the benefit arises from a longer time-base during which oxygen-induced depolarization modifies the signal strength. Demonstration of the accelerated technique in human studies shows the feasibility of the method and suggests that measurement error is reduced here as well, particularly at low signal-to-noise levels. Copyright © 2013 AUR. Published by Elsevier Inc. All rights reserved.

  2. Molecular MRI based on hyper-polarized xenon

    International Nuclear Information System (INIS)

    Tassali, Nawal

    2012-01-01

    Magnetic Resonance Imaging (MRI) has a high importance in medicine as it enables the observation of the organs inside the body without the use of radiative or invasive techniques. However it is known to suffer from poor sensitivity. To circumvent this limitation, a key solution resides in the use of hyper-polarized species. Among the entities with which we can drastically increase nuclear polarization, xenon has very specific properties through its interactions with its close environment that lead to a wide chemical shift bandwidth. The goal is thus to use it as a tracer. This PhD thesis focuses on the concept of 129 Xe MRI-based sensors for the detection of biological events. In this approach, hyper-polarized xenon is vectorized to biological targets via functionalized host systems, and then localized thanks to fast dedicated MRI sequences. The conception and set-up of a spin-exchange optical pumping device is first described. Then studies about the interaction of the hyper-polarized noble gas with new cryptophanes susceptible to constitute powerful host molecules are detailed. Also the implementation of recent MRI sequences optimized for the transient character of the hyper-polarization and taking profit of the xenon in-out exchange is described. Applications of this approach for the detection of metallic ions and cellular receptors are studied. Finally, our first in vivo results on a small animal model are presented. (author) [fr

  3. Signal-to-noise ratio, T2 , and T2* for hyperpolarized helium-3 MRI of the human lung at three magnetic field strengths.

    Science.gov (United States)

    Komlosi, Peter; Altes, Talissa A; Qing, Kun; Mooney, Karen E; Miller, G Wilson; Mata, Jaime F; de Lange, Eduard E; Tobias, William A; Cates, Gordon D; Mugler, John P

    2017-10-01

    To evaluate T 2 , T2*, and signal-to-noise ratio (SNR) for hyperpolarized helium-3 ( 3 He) MRI of the human lung at three magnetic field strengths ranging from 0.43T to 1.5T. Sixteen healthy volunteers were imaged using a commercial whole body scanner at 0.43T, 0.79T, and 1.5T. Whole-lung T 2 values were calculated from a Carr-Purcell-Meiboom-Gill spin-echo-train acquisition. T2* maps and SNR were determined from dual-echo and single-echo gradient-echo images, respectively. Mean whole-lung SNR values were normalized by ventilated lung volume and administered 3 He dose. As expected, T 2 and T2* values demonstrated a significant inverse relationship to field strength. Hyperpolarized 3 He images acquired at all three field strengths had comparable SNR values and thus appeared visually very similar. Nonetheless, the relatively small SNR differences among field strengths were statistically significant. Hyperpolarized 3 He images of the human lung with similar image quality were obtained at three field strengths ranging from 0.43T and 1.5T. The decrease in susceptibility effects at lower fields that are reflected in longer T 2 and T2* values may be advantageous for optimizing pulse sequences inherently sensitive to such effects. The three-fold increase in T2* at lower field strength would allow lower receiver bandwidths, providing a concomitant decrease in noise and relative increase in SNR. Magn Reson Med 78:1458-1463, 2017. © 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.

  4. 3He-MRI in follow-up of lung transplant recipients

    International Nuclear Information System (INIS)

    Gast, Klaus Kurt; Zaporozhan, Julia; Ley, Sebastian; Biedermann, Alexander; Knitz, Frank; Eberle, Balthasar; Schmiedeskamp, Joerg; Heussel, Claus-Peter; Mayer, Eckhard; Schreiber, Wolfgang Guenter; Thelen, Manfred; Kauczor, Hans-Ulrich

    2004-01-01

    The aim of this study was to evaluate the possible contribution of 3 He-MRI to detect obliterative bronchiolitis (OB) in the follow-up of lung transplant recipients. Nine single- and double-lung transplanted patients were studied by an initial and a follow-up 3 He-MRI study. Images were evaluated subjectively by estimation of ventilation defect area and quantitatively by individually adapted threshold segmentation and subsequent calculation of ventilated lung volume. Bronchiolitis obliterans syndrome (BOS) was diagnosed using pulmonary function tests. At 3 He-MRI, OB was suspected if ventilated lung volume had decreased by 10% or more at the follow-up MRI study compared with the initial study. General accordance between pulmonary function testing and 3 He-MRI was good, although subjective evaluation of 3 He-MRI underestimated improvement in ventilation as obtained by pulmonary function tests. The 3 He-MRI indicated OB in 6 cases. According to pulmonary function tests, BOS was diagnosed in 5 cases. All diagnoses of BOS were also detected by 3 He-MRI. In 2 of these 5 cases, 3 He-MRI indicated OB earlier than pulmonary function tests. The results support the hypothesis that 3 He-MRI may be sensitive for early detection of OB and emphasize the need for larger prospective follow-up studies. (orig.)

  5. Emphysematous changes and normal variation in smokers and COPD patients using diffusion 3He MRI

    International Nuclear Information System (INIS)

    Swift, Andrew J.; Wild, Jim M.; Fichele, Stan; Woodhouse, Neil; Fleming, Sally; Waterhouse, Judith; Lawson, Rod A.; Paley, Martyn N.J.; Van Beek, Edwin J.R.

    2005-01-01

    Introduction: This study aims to quantify global and regional changes of diffusive motion of 3 He gas within the lung, as determined by hyperpolarized 3 He MR apparent diffusion coefficient (ADC) measurement, in non-smokers, smokers and chronic obstructive pulmonary disease (COPD) patients. Methods: Age-matched groups of six healthy non-smokers, five healthy smokers and five patients with COPD. The experiments were performed with approval from the local Research Ethics Committee. Diffusion imaging was performed following hyperpolarized 3 He gas inhalation, producing ADC maps. Mean and standard deviation of the ADCs were used to compare the subject groups and assess regional variations within individuals. Results: The intra-individual standard deviation of ADC in the healthy smokers was significantly larger than that of the non-smoking group (P < 0.02). Compared to the non-smoking group, COPD patients had significantly higher mean and standard deviation of ADC (P < 0.01). The mean ADC in the anterior half of the chest was systematically higher than in the posterior half in the healthy non-smoking subject group. Discussion: This study suggests that there are regional trends in the ADC values of healthy volunteers that may have implications for the clinical interpretation of ADC values. Less homogeneous ADC values have been detected in asymptomatic smokers, indicative of damage to the distal air spaces

  6. Optical Pumping Spin Exchange 3He Gas Cells for Magnetic Resonance Imaging

    Science.gov (United States)

    Kim, W.; Stepanyan, S. S.; Kim, A.; Jung, Y.; Woo, S.; Yurov, M.; Jang, J.

    2009-08-01

    We present a device for spin-exchange optical pumping system to produce large quantities of polarized noble gases for Magnetic Resonance Imaging (MRI). A method and design of apparatus for pumping the polarization of noble gases is described. The method and apparatus enable production, storage and usage of hyperpolarized noble gases for different purposes, including Magnetic Resonance Imaging of human and animal subjects. Magnetic imaging agents breathed into lungs can be observed by the radio waves of the MRI scanner and report back physical and functional information about lung's health and desease. The technique known as spin exchange optical pumping is used. Nuclear magnetic resonance is implemented to measure the polarization of hyperpolarized gas. The cells prepared and sealed under high vacuum after handling Alkali metals into the cell and filling with the 3He-N2 mixture. The cells could be refilled. The 3He reaches around 50% polarization in 5-15 hours.

  7. Measurement of lung airways in three dimensions using hyperpolarized helium-3 MRI

    International Nuclear Information System (INIS)

    Peterson, Eric T; Fain, Sean B; Dai Jionghan; Holmes, James H

    2011-01-01

    Large airway measurement is clinically important in cases of airway disease and trauma. The gold standard is computed tomography (CT), which allows for airway measurement. However, the ionizing radiation dose associated with CT is a major limitation in longitudinal studies and trauma. To avoid ionizing radiation from CT, we present a method for measuring the large airway diameter in humans using hyperpolarized helium-3 (HPHe) MRI in conjunction with a dynamic 3D radial acquisition. An algorithm is introduced which utilizes the significant airway contrast for semi-automated segmentation and skeletonization which is used to derive the airway lumen diameter. The HPHe MRI method was validated with quantitative CT in an excised and desiccated porcine lung (linear regression R 2 = 0.974 and slope = 0.966 over 32 airway segments). The airway lumen diameters were then compared in 24 human subjects (22 asthmatics and 2 normals; linear regression R 2 value of 0.799 and slope = 0.768 over 309 airway segments). The feasibility for airway path analysis to areas of ventilation defect is also demonstrated.

  8. Low Cost, High-Throughput 3-D Pulmonary Imager Using Hyperpolarized Contrast Agents and Low-Field MRI

    Science.gov (United States)

    2017-10-01

    greater gas polarizations and production amounts/ throughputs- benefiting in particular from the advent of com- pact, high-power, relatively low- cost ...Award Number: W81XWH-15-1-0271 TITLE: Low- Cost , High-Throughput 3-D Pulmonary Imager Using Hyperpolarized Contrast Agents and Low-Field MRI...DISTRIBUTION STATEMENT: Approved for Public Release; Distribution Unlimited The views, opinions and/or findings contained in this report are those of the

  9. TH-CD-202-09: Free-Breathing Proton MRI Functional Lung Avoidance Maps to Guide Radiation Therapy

    International Nuclear Information System (INIS)

    Capaldi, D; Sheikh, K; Parraga, G; Hoover, D; Yaremko, B; Palma, D

    2016-01-01

    Purpose: Pulmonary functional MRI using inhaled gas contrast agents was previously investigated as a way to identify well-functioning lung in patients with NSCLC who are clinical candidates for radiotherapy. Hyperpolarized noble-gas ( 3 He and 129 Xe) MRI has also been optimized to measure functional lung information, but for a number of reasons, the clinical translation of this approach to guide radiotherapy planning has been limited. As an alternative, free-breathing pulmonary 1H MRI using clinically available MRI systems and pulse sequences provides a non-contrast-enhanced method to generate both ventilation and perfusion maps. Free-breathing 1 H MRI exploits non-rigid registration and Fourier decomposition of MRI signal intensity differences (Bauman et al., MRM, 2009) that may be generated during normal tidal breathing. Here, our objective was to generate free-breathing 1 H MRI ventilation and lung function avoidance maps in patients with NSCLC as a way to guide radiation therapy planning. Methods: Stage IIIA/IIIB NSCLC patients (n=8, 68±9yr) provided written informed consent to a randomized controlled clinical trial ( https://clinicaltrials.gov/ct2/show/NCT02002052 ) that aimed to compare outcomes related to image-guided versus conventional radiation therapy planning. Hyperpolarized 3 He/ 129 Xe and dynamic free tidal-breathing 1 H MRI were acquired as previously described (Capaldi et al., Acad Radiol, 2015). Non-rigid registration was performed using the modality-independent-neighbourhood-descriptor (MIND) deformable approach (Heinrich et al., Med Image Anal, 2012). Ventilation-defect-percent ( 3 He:VDP He , 129 Xe:VDP Xe , Free-breathing- 1 H:VDP FB ) and the corresponding ventilation maps were compared using Pearson correlation coefficients (r) and the Dice similarity coefficient (DSC). Results: VDP FB was significantly related to VDP He (r=.71; p=.04) and VDP Xe (r=.80; p=.01) and there were also strong spatial relationships (DSC He /DSC Xe =89±3%/77±11

  10. Low-Cost, High-Throughput 3-D Pulmonary Imager Using Hyperpolarized Contrast Agents and Low-Field MRI

    Science.gov (United States)

    2017-10-01

    low- cost and high-throughput was a key element proposed for this project, which we believe will be of significant benefit to the patients suffering...Award Number: W81XWH-15-1-0272 TITLE: Low- Cost , High-Throughput 3-D Pulmonary Imager Using Hyperpolarized Contrast Agents and Low-Field MRI...STATEMENT: Approved for Public Release; Distribution Unlimited The views, opinions and/or findings contained in this report are those of the author(s

  11. The role of hyperpolarized 129xenon in MR imaging of pulmonary function

    International Nuclear Information System (INIS)

    Ebner, Lukas; Kammerman, Jeff; Driehuys, Bastiaan; Schiebler, Mark L.; Cadman, Robert V.; Fain, Sean B.

    2017-01-01

    Highlights: • Recent advances in hyperpolarized 129Xe MRI are reviewed. • Xenon MRI allows for functional imaging of ventilation, diffusion, and gas exchange. • Xenon’s unique gas exchange imaging capabilities are highlighted. • Applications to obstructive and restrictive lung diseases are presented. • These advances are ready for translation to clinical applications. - Abstract: In the last two decades, functional imaging of the lungs using hyperpolarized noble gases has entered the clinical stage. Both helium ( 3 He) and xenon ( 129 Xe) gas have been thoroughly investigated for their ability to assess both the global and regional patterns of lung ventilation. With advances in polarizer technology and the current transition towards the widely available 129 Xe gas, this method is ready for translation to the clinic. Currently, hyperpolarized (HP) noble gas lung MRI is limited to selected academic institutions; yet, the promising results from initial clinical trials have drawn the attention of the pulmonary medicine community. HP 129 Xe MRI provides not only 3-dimensional ventilation imaging, but also unique capabilities for probing regional lung physiology. In this review article, we aim to (1) provide a brief overview of current ventilation MR imaging techniques, (2) emphasize the role of HP 129 Xe MRI within the array of different imaging strategies, (3) discuss the unique imaging possibilities with HP 129 Xe MRI, and (4) propose clinical applications.

  12. Oxygen-sensitive 3He-MRI in bronchiolitis obliterans after lung transplantation

    International Nuclear Information System (INIS)

    Gast, Klaus K.; Biedermann, Alexander; Herweling, Annette; Schreiber, Wolfgang G.; Schmiedeskamp, Joerg; Mayer, Eckhard; Heussel, Claus P.; Markstaller, Klaus; Eberle, Balthasar; Kauczor, Hans-Ulrich

    2008-01-01

    Oxygen-sensitive 3 He-MRI was studied for the detection of differences in intrapulmonary oxygen partial pressure (pO 2 ) between patients with normal lung transplants and those with bronchiolitis obliterans syndrome (BOS). Using software developed in-house, oxygen-sensitive 3 He-MRI datasets from patients with normal lung grafts (n = 8) and with BOS (n = 6) were evaluated quantitatively. Datasets were acquired on a 1.5-T system using a spoiled gradient echo pulse sequence. Underlying diseases were pulmonary emphysema (n 10 datasets) and fibrosis (n = 4). BOS status was verified by pulmonary function tests. Additionally, 3 He-MRI was assessed blindedly for ventilation defects. Median intrapulmonary pO 2 in patients with normal lung grafts was 146 mbar compared with 108 mbar in patients with BOS. Homogeneity of pO2 distribution was greater in normal grafts (standard deviation pO2 34 versus 43 mbar). Median oxygen decrease rate during breath hold was higher in unaffected patients (-1.75 mbar/s versus -0.38 mbar/s). Normal grafts showed fewer ventilation defects (5% versus 28%, medians). Oxygen-sensitive 3 He-MRI appears capable of demonstrating differences of intrapulmonary pO2 between normal lung grafts and grafts affected by BOS. Oxygen-sensitive 3 He-MRI may add helpful regional information to other diagnostic techniques for the assessment and follow-up of lung transplant recipients. (orig.)

  13. Transportable hyperpolarized metabolites

    Science.gov (United States)

    Ji, Xiao; Bornet, Aurélien; Vuichoud, Basile; Milani, Jonas; Gajan, David; Rossini, Aaron J.; Emsley, Lyndon; Bodenhausen, Geoffrey; Jannin, Sami

    2017-01-01

    Nuclear spin hyperpolarization of 13C-labelled metabolites by dissolution dynamic nuclear polarization can enhance the NMR signals of metabolites by several orders of magnitude, which has enabled in vivo metabolic imaging by MRI. However, because of the short lifetime of the hyperpolarized magnetization (typically <1 min), the polarization process must be carried out close to the point of use. Here we introduce a concept that markedly extends hyperpolarization lifetimes and enables the transportation of hyperpolarized metabolites. The hyperpolarized sample can thus be removed from the polarizer and stored or transported for use at remote MRI or NMR sites. We show that hyperpolarization in alanine and glycine survives 16 h storage and transport, maintaining overall polarization enhancements of up to three orders of magnitude. PMID:28072398

  14. 3D Hyperpolarized C-13 EPI with Calibrationless Parallel Imaging

    DEFF Research Database (Denmark)

    Gordon, Jeremy W.; Hansen, Rie Beck; Shin, Peter J.

    2018-01-01

    With the translation of metabolic MRI with hyperpolarized 13C agents into the clinic, imaging approaches will require large volumetric FOVs to support clinical applications. Parallel imaging techniques will be crucial to increasing volumetric scan coverage while minimizing RF requirements and tem...... strategies to accelerate and undersample hyperpolarized 13C data using 3D blipped EPI acquisitions and multichannel receive coils, and demonstrated its application in a human study of [1-13C]pyruvate metabolism....

  15. TH-CD-202-09: Free-Breathing Proton MRI Functional Lung Avoidance Maps to Guide Radiation Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Capaldi, D; Sheikh, K; Parraga, G [Robarts Research Institute, The University of Western Ontario, London, Ontario, CA (United States); Department of Medical Biophysics, The University of Western Ontario, London, Ontario, CA (United States); Hoover, D; Yaremko, B; Palma, D [Department of Medical Biophysics, The University of Western Ontario, London, Ontario, CA (United States); Department of Oncology, The University of Western Ontario, London, Ontario, CA (United States)

    2016-06-15

    Purpose: Pulmonary functional MRI using inhaled gas contrast agents was previously investigated as a way to identify well-functioning lung in patients with NSCLC who are clinical candidates for radiotherapy. Hyperpolarized noble-gas ({sup 3}He and {sup 129}Xe) MRI has also been optimized to measure functional lung information, but for a number of reasons, the clinical translation of this approach to guide radiotherapy planning has been limited. As an alternative, free-breathing pulmonary 1H MRI using clinically available MRI systems and pulse sequences provides a non-contrast-enhanced method to generate both ventilation and perfusion maps. Free-breathing {sup 1}H MRI exploits non-rigid registration and Fourier decomposition of MRI signal intensity differences (Bauman et al., MRM, 2009) that may be generated during normal tidal breathing. Here, our objective was to generate free-breathing {sup 1}H MRI ventilation and lung function avoidance maps in patients with NSCLC as a way to guide radiation therapy planning. Methods: Stage IIIA/IIIB NSCLC patients (n=8, 68±9yr) provided written informed consent to a randomized controlled clinical trial ( https://clinicaltrials.gov/ct2/show/NCT02002052 ) that aimed to compare outcomes related to image-guided versus conventional radiation therapy planning. Hyperpolarized {sup 3}He/{sup 129}Xe and dynamic free tidal-breathing {sup 1}H MRI were acquired as previously described (Capaldi et al., Acad Radiol, 2015). Non-rigid registration was performed using the modality-independent-neighbourhood-descriptor (MIND) deformable approach (Heinrich et al., Med Image Anal, 2012). Ventilation-defect-percent ({sup 3}He:VDP{sub He}, {sup 129}Xe:VDP{sub Xe}, Free-breathing-{sup 1}H:VDP{sub FB}) and the corresponding ventilation maps were compared using Pearson correlation coefficients (r) and the Dice similarity coefficient (DSC). Results: VDP{sub FB} was significantly related to VDP{sub He} (r=.71; p=.04) and VDP{sub Xe} (r=.80; p=.01) and

  16. The role of hyperpolarized {sup 129}xenon in MR imaging of pulmonary function

    Energy Technology Data Exchange (ETDEWEB)

    Ebner, Lukas [Cardiothoracic Imaging, Duke University Medical Center, Department of Radiology, Duke University, Durham, NC (United States); Kammerman, Jeff [Department of Medical Physics, University of Wisconsin, Madison, WI (United States); Driehuys, Bastiaan [Center for In Vivo Microscopy, Duke University, Durham, NC (United States); Schiebler, Mark L. [Department of Radiology, University of Wisconsin, Madison, WI (United States); Cadman, Robert V. [Department of Medical Physics, University of Wisconsin, Madison, WI (United States); Fain, Sean B., E-mail: sfain@wisc.edu [Departments of Medical Physics, Radiology, and Biomedical Engineering, University of Wisconsin, Madison, WI (United States)

    2017-01-15

    Highlights: • Recent advances in hyperpolarized 129Xe MRI are reviewed. • Xenon MRI allows for functional imaging of ventilation, diffusion, and gas exchange. • Xenon’s unique gas exchange imaging capabilities are highlighted. • Applications to obstructive and restrictive lung diseases are presented. • These advances are ready for translation to clinical applications. - Abstract: In the last two decades, functional imaging of the lungs using hyperpolarized noble gases has entered the clinical stage. Both helium ({sup 3}He) and xenon ({sup 129}Xe) gas have been thoroughly investigated for their ability to assess both the global and regional patterns of lung ventilation. With advances in polarizer technology and the current transition towards the widely available {sup 129}Xe gas, this method is ready for translation to the clinic. Currently, hyperpolarized (HP) noble gas lung MRI is limited to selected academic institutions; yet, the promising results from initial clinical trials have drawn the attention of the pulmonary medicine community. HP {sup 129}Xe MRI provides not only 3-dimensional ventilation imaging, but also unique capabilities for probing regional lung physiology. In this review article, we aim to (1) provide a brief overview of current ventilation MR imaging techniques, (2) emphasize the role of HP {sup 129}Xe MRI within the array of different imaging strategies, (3) discuss the unique imaging possibilities with HP {sup 129}Xe MRI, and (4) propose clinical applications.

  17. Visualize Diffusion Map of COPD Rat with Hyperpolarized Xenon MRI%超极化Xenon对慢阻肺的可视化加权成像

    Institute of Scientific and Technical Information of China (English)

    阮伟伟; 钟俭平; 韩叶清; 孙献平; 叶朝辉; 周欣

    2015-01-01

    Hyperpolarized3He or129Xe diffusion MRI has been demonstrated as a promising technique for the detection of microanatomical changes in chronic obstructive pulmonary disease (COPD). Compared with 3He,129Xe is more available for the potential clinical applications. However, the measurement of129Xe apparent diffusion coefficient (ADC) possesses more challenges due to the relevant low gyromagnetic ratio and spin polarization. In this present study, a singleb value (b = 14 s/cm2) diffusion-weighted hyperpolarized129Xe MRI sequence was used to image a balloon phantom, healthy rats, and the COPD rats, respectively. All COPD rats were induced by second-hand smoke and lipopolysaccharide (LPS). The lung129XeADCmaps were obtained on a 7 T MRI scanner. The mean lung parenchymal129XeADCswere 0.044 22±0.002 9 and 0.042 34±0.002 3 cm2/s (Δ = 0.8/1.2 ms) for the COPD rats, which showed significant increasements in comparison with healthy ones (0.037 7±0.002 3 and 0.036 7±0.001 3 cm2/s). Furthermore, the correspondingADChistogram of the COPD rats exhibited a broader distribution as compared with the healthy ones. Our experiments demonstrated that the alveolar airspace enlargement in the COPD rats are able to be quantitatively evaluated by hyperpolarized xenon diffusion-weighted MRI.%超极化气体3He或者129Xe扩散加权成像已经被证明了能够有效检测慢性阻塞性肺部疾病(COPD)中肺部微结构的改变.相比于3He,129Xe更便宜而且更容易获得,但是129Xe成像中较低的信噪比致使129Xe 的肺部表面扩散系数(ADC)的测量面临着许多困难.在该研究中,为了得到更高的图像信噪比,作者对气球模型,健康大鼠和COPD大鼠进行了单个b值(14 cm2/s)的扩散加权超极化129Xe磁共振成像(MRI).所有的COPD模型大鼠是通过烟熏和注射内毒素(LPS)进行诱导得到的.在7 T磁共振成像仪上面获得了大鼠肺实质的超极化129Xe ADC值分布图.COPD大鼠肺实质的129Xe

  18. Physical interactions of hyperpolarized gas in the lung

    Science.gov (United States)

    Chen, Xiu-Hao Josette

    1999-09-01

    This thesis addresses key interactions of hyperpolarized (HP) gas within the biological environment of the lung using magnetic resonance imaging (MRI). The first excised lung image was obtained in 1994 by Albert et al ., indicating the relative youth of the HP gas MRI field. Thus, there are a multitude of parameters which need to be explored to optimize contrast mechanisms and pulse sequences for in vivo applications. To perform HP gas MRI, both the production of HP gas and development of appropriate MRI pulse sequences were necessary. The apparatus for gas polarization was transferred from Princeton University, then modified and optimized to provide larger quantities and higher polarizations. It was ultimately replaced by a prototype commercial apparatus. Existing MRI pulse sequences were changed to accommodate and exploit the unique situation of non-equilibrium polarized gas. Several physical parameters of the gas relating to structure and function in the lung were investigated. It was found that using a range of excitation powers, acquisition windows, and ventilatory cycle segments yielded dramatically different types of images in the guinea pig. Spatially localized lineshapes of HP 3He showed differentiated peaks (corresponding to frequency shifts) which represent gas in major airways (2 ppm) and alveoli (1-2 ppm). Quantitative maps of the diffusion coefficient (D) showed evidence of free diffusion in the trachea (average of 2.4 cm2/s for 3He and 0.68 cm2/s for 129Xe) and restricted diffusion combined with effects of gas mixtures in the distal pulmonary airspaces (average of 0.16 cm2/s for 3He and 0.021 cm2/s for 129Xe). Experimental measurements were verified with gas mixture and porous media theory for both 3He and 129Xe. The dephasing parameter, T*2 , was mapped showing sensitivity to changes in tidal volume and oxygen level. The T*2 values ranged from 9.2 to 15.9 ms in the intrapulmonary airspaces depending on the breathing paradigm. Experimental results

  19. Characterization and optimization of the visualization performance of continuous flow overhauser DNP hyperpolarized water MRI: Inversion recovery approach.

    Science.gov (United States)

    Terekhov, Maxim; Krummenacker, Jan; Denysenkov, Vasyl; Gerz, Kathrin; Prisner, Thomas; Schreiber, Laura Maria

    2016-03-01

    Overhauser dynamic nuclear polarization (DNP) allows the production of liquid hyperpolarized substrate inside the MRI magnet bore as well as its administration in continuous flow mode to acquire MR images with enhanced signal-to-noise ratio. We implemented inversion recovery preparation in order to improve contrast-to-noise ratio and to quantify the overall imaging performance of Overhauser DNP-enhanced MRI. The negative enhancement created by DNP in combination with inversion recovery (IR) preparation allows canceling selectively the signal originated from Boltzmann magnetization and visualizing only hyperpolarized fluid. The theoretical model describing gain of MR image intensity produced by steady-state continuous flow DNP hyperpolarized magnetization was established and proved experimentally. A precise quantification of signal originated purely from DNP hyperpolarization was achieved. A temperature effect on longitudinal relaxation had to be taken into account to fit experimental results with numerical prediction. Using properly adjusted IR preparation, the complete zeroing of thermal background magnetization was achieved, providing an essential increase of contrast-to-noise ratio of DNP-hyperpolarized water images. To quantify and optimize the steady-state conditions for MRI with continuous flow DNP, an approach similar to that incorporating transient-state thermal magnetization equilibrium in spoiled fast field echo imaging sequences can be used. © 2015 Wiley Periodicals, Inc.

  20. New insights into lung diseases using hyperpolarized gas MRI.

    Science.gov (United States)

    Flors, L; Altes, T A; Mugler, J P; de Lange, E E; Miller, G W; Mata, J F; Ruset, I C; Hersman, F W

    2015-01-01

    Hyperpolarized (HP) gases are a new class of contrast agents that permit to obtain high temporal and spatial resolution magnetic resonance images (MRI) of the lung airspaces. HP gas MRI has become important research tool not only for morphological and functional evaluation of normal pulmonary physiology but also for regional quantification of pathologic changes occurring in several lung diseases. The purpose of this work is to provide an introduction to MRI using HP noble gases, describing both the basic principles of the technique and the new information about lung disease provided by clinical studies with this method. The applications of the technique in normal subjects, smoking related lung disease, asthma, and cystic fibrosis are reviewed. Copyright © 2014 SERAM. Published by Elsevier España, S.L.U. All rights reserved.

  1. Nanodiamond-enhanced MRI via in situ hyperpolarization

    Science.gov (United States)

    Waddington, David E. J.; Sarracanie, Mathieu; Zhang, Huiliang; Salameh, Najat; Glenn, David R.; Rej, Ewa; Gaebel, Torsten; Boele, Thomas; Walsworth, Ronald L.; Reilly, David J.; Rosen, Matthew S.

    2017-04-01

    Nanodiamonds are of interest as nontoxic substrates for targeted drug delivery and as highly biostable fluorescent markers for cellular tracking. Beyond optical techniques, however, options for noninvasive imaging of nanodiamonds in vivo are severely limited. Here, we demonstrate that the Overhauser effect, a proton-electron polarization transfer technique, can enable high-contrast magnetic resonance imaging (MRI) of nanodiamonds in water at room temperature and ultra-low magnetic field. The technique transfers spin polarization from paramagnetic impurities at nanodiamond surfaces to 1H spins in the surrounding water solution, creating MRI contrast on-demand. We examine the conditions required for maximum enhancement as well as the ultimate sensitivity of the technique. The ability to perform continuous in situ hyperpolarization via the Overhauser mechanism, in combination with the excellent in vivo stability of nanodiamond, raises the possibility of performing noninvasive in vivo tracking of nanodiamond over indefinitely long periods of time.

  2. A short-breath-hold technique for lung pO2 mapping with 3He MRI.

    Science.gov (United States)

    Miller, G Wilson; Mugler, John P; Altes, Talissa A; Cai, Jing; Mata, Jaime F; de Lange, Eduard E; Tobias, William A; Cates, Gordon D; Brookeman, James R

    2010-01-01

    A pulse-sequence strategy was developed for generating regional maps of alveolar oxygen partial pressure (pO2) in a single 6-sec breath hold, for use in human subjects with impaired lung function. Like previously described methods, pO2 values are obtained by measuring the oxygen-induced T1 relaxation of inhaled hyperpolarized 3He. Unlike other methods, only two 3He images are acquired: one with reverse-centric and the other with centric phase-encoding order. This phase-encoding arrangement minimizes the effects of regional flip-angle variations, so that an accurate map of instantaneous pO2 can be calculated from two images acquired a few seconds apart. By combining this phase-encoding strategy with variable flip angles, the vast majority of the hyperpolarized magnetization goes directly into the T1 measurement, minimizing noise in the resulting pO2 map. The short-breath-hold pulse sequence was tested in phantoms containing known O2 concentrations. The mean difference between measured and prepared pO2 values was 1 mm Hg. The method was also tested in four healthy volunteers and three lung-transplant patients. Maps of healthy subjects were largely uniform, whereas focal regions of abnormal pO2 were observed in diseased subjects. Mean pO2 values varied with inhaled O2 concentration. Mean pO2 was consistent with normal steady-state values in subjects who inhaled 3He diluted only with room air. Copyright (c) 2009 Wiley-Liss, Inc.

  3. Measurement of alveolar oxygen partial pressure in the rat lung using Carr-Purcell-Meiboom-Gill spin-spin relaxation times of hyperpolarized 3He and 129Xe at 74 mT.

    Science.gov (United States)

    Kraayvanger, Ryan J; Bidinosti, Christopher P; Dominguez-Viqueira, William; Parra-Robles, Juan; Fox, Matthew; Lam, Wilfred W; Santyr, Giles E

    2010-11-01

    Regional measurement of alveolar oxygen partial pressure can be obtained from the relaxation rates of hyperpolarized noble gases, (3) He and (129) Xe, in the lungs. Recently, it has been demonstrated that measurements of alveolar oxygen partial pressure can be obtained using the spin-spin relaxation rate (R(2) ) of (3) He at low magnetic field strengths (oxygen partial pressure measurements based on Carr-Purcell-Meiboom-Gill R(2) values of hyperpolarized (3) He and (129) Xe in vitro and in vivo in the rat lung at low magnetic field strength (74 mT) are presented. In vitro spin-spin relaxivity constants for (3) He and (129) Xe were determined to be (5.2 ± 0.6) × 10(-6) Pa(-1) sec(-1) and (7.3 ± 0.4) × 10(-6) Pa(-1) s(-1) compared with spin-lattice relaxivity constants of (4.0 ± 0.4) × 10(-6) Pa(-1) s(-1) and (4.3 ± 1.3) × 10(-6) Pa(-1) s(-1), respectively. In vivo experimental measurements of alveolar oxygen partial pressure using (3) He in whole rat lung show good agreement (r(2) = 0.973) with predictions based on lung volumes and ventilation parameters. For (129) Xe, multicomponent relaxation was observed with one component exhibiting an increase in R(2) with decreasing alveolar oxygen partial pressure. Copyright © 2010 Wiley-Liss, Inc.

  4. Real-time tracking of dissociation of hyperpolarized 89Y-DTPA: a model for degradation of open-chain Gd3+ MRI contrast agents

    Science.gov (United States)

    Ferguson, Sarah; Niedbalski, Peter; Parish, Christopher; Kiswandhi, Andhika; Kovacs, Zoltan; Lumata, Lloyd

    Gadolinium (Gd) complexes are widely used relaxation-based clinical contrast agents in magnetic resonance imaging (MRI). Gd-based MRI contrast agents with open-chain ligand such as Gd-DTPA, commercially known as magnevist, are less stable compared to Gd complexes with macrocyclic ligands such as GdDOTA (Dotarem). The dissociation of Gd-DPTA into Gd ion and DTPA ligand under certain biological conditions such as high zinc levels can potentially cause kidney damage. Since Gd is paramagnetic, direct NMR detection of the Gd-DTPA dissociation is quite challenging due to ultra-short relaxation times. In this work, we have investigated Y-DTPA as a model for Gd-DPTA dissociation under high zinc content solutions. Using dissolution dynamic nuclear polarization (DNP), the 89Y NMR signal is amplified by several thousand-fold. Due to the the relatively long T1 relaxation time of 89Y which translates to hyperpolarization lifetime of several minutes, the dissociation of Y-DTPA can be tracked in real-time by hyperpolarized 89Y NMR spectroscopy. Dissociation kinetic rates and implications on the degradation of open-chain Gd3+ MRI contrast agents will be discussed. This work was supported by the U.S. Department of Defense Award Number W81XWH-14-1-0048 and by the Robert A. Welch Foundation research Grant Number AT-1877.

  5. Effects of anesthesia on renal function and metabolism in rats assessed by hyperpolarized MRI

    DEFF Research Database (Denmark)

    Qi, Haiyun; Mariager, Christian Østergaard; Lindhardt, Jakob

    2018-01-01

    . In the present study, we aimed to investigate the renal functional and metabolic consequences of 3 typical rodent anesthetics used in preclinical MRI: sevoflurane, inaction, and a mixture of fentanyl, fluanisone, and midazolam (FFM). METHODS: The renal effects of 3 different classes of anesthetics (inactin......, servoflurane, and FFM) were investigated using functional and metabolic MRI. The renal glucose metabolism and hemodynamics was characterized with hyperpolarized [1-13C]pyruvate MRI and by DCE imaging. RESULTS: Rats receiving sevoflurane or FFM had blood glucose levels that were 1.3-fold to 1.4-fold higher than...... rats receiving inactin. A 2.9-fold and 4.8-fold increased13C-lactate/13C-pyruvate ratio was found in the FFM mixture anesthetized group compared with the sevoflurane and the inactin anesthetized groups. The FFM anesthesia resulted in a 50% lower renal plasma flow compared with the sevoflurane...

  6. NMR and superfluidity of 3He in 3He-4He solutions

    International Nuclear Information System (INIS)

    Ivanova, K.D.; Mejerovich, A.Eh.

    1986-01-01

    Two possibilities of determining the superfluid transition temperature for 3 He in a 3 He- 4 He solution by the NMR technique are discussed. One of the methods consists in measuring the spin diffusion coefficient in weak magnetic fields at ultralow temperatures, and the other in measuring the ratio of the spin diffusion coefficient to the spin wave absorption coefficient at not very low temperatures. The transition temperature is estimated on the basis of the available experimental data. The effect of the superfluid transition in a system of 3 He quasiparticles on the propagation of transverse spin waves and longitudinal spin-sound oscillations in 3 He- 4 He solutions is studied. It is shown that there is a range of weak magnetic field intensities restricted from both sides in which the propagation of weakly damped spin-sound waves is possible

  7. Validating excised rodent lungs for functional hyperpolarized xenon-129 MRI.

    Directory of Open Access Journals (Sweden)

    David M L Lilburn

    Full Text Available Ex vivo rodent lung models are explored for physiological measurements of respiratory function with hyperpolarized (hp (129Xe MRI. It is shown that excised lung models allow for simplification of the technical challenges involved and provide valuable physiological insights that are not feasible using in vivo MRI protocols. A custom designed breathing apparatus enables MR images of gas distribution on increasing ventilation volumes of actively inhaled hp (129Xe. Straightforward hp (129Xe MRI protocols provide residual lung volume (RV data and permit for spatially resolved tracking of small hp (129Xe probe volumes during the inhalation cycle. Hp (129Xe MRI of lung function in the excised organ demonstrates the persistence of post mortem airway responsiveness to intravenous methacholine challenges. The presented methodology enables physiology of lung function in health and disease without additional regulatory approval requirements and reduces the technical and logistical challenges with hp gas MRI experiments. The post mortem lung functional data can augment histological measurements and should be of interest for drug development studies.

  8. The role of level anti-crossings in nuclear spin hyperpolarization

    NARCIS (Netherlands)

    Ivanov, Konstantin L.; Pravdivtsev, Andrey N.; Yurkovskaya, Alexandra V.; Vieth, Hans Martin; Kaptein, R

    2014-01-01

    Nuclear spin hyperpolarization is an important resource for increasing the sensitivity of NMR spectroscopy and MRI. Signal enhancements can be as large as 3-4 orders of magnitude. In hyperpolarization experiments, it is often desirable to transfer the initial polarization to other nuclei of choice,

  9. Investigating tumor perfusion by hyperpolarized (13) C MRI with comparison to conventional gadolinium contrast-enhanced MRI and pathology in orthotopic human GBM xenografts

    DEFF Research Database (Denmark)

    Park, Ilwoo; von Morze, Cornelius; Lupo, Janine M

    2016-01-01

    glioblastoma (GBM) model for the characterization of tumor perfusion and compared with standard Gd-based dynamic susceptibility contrast (DSC) MRI data and immunohistochemical analysis from resected brains. Distinct HMCP perfusion characteristics were observed within the GBM tumors compared with contralateral...... for tumor that exhibited high levels of hyperpolarized HMCP signal. The results from this study have demonstrated that hyperpolarized HMCP data can be used as an indicator of tumor perfusion in an orthotopic xenograft model for GBM. Magn Reson Med, 2016. © 2016 Wiley Periodicals, Inc....

  10. Hyperpolarized 13C-Urea MRI for the assessment of the urea gradient in the porcine kidney

    DEFF Research Database (Denmark)

    Søvsø Szocska Hansen, Esben; Stewart, Neil James; Wild, Jim Michael

    Renal anatomical and pathophysiological alterations are directly associated with the fluid and electrolyte balance in the kidney, which is regulated by the extracellular corticomedullary osmolality gradient. We introduce a novel magnetic resonance imaging (MRI) approach to monitor...... treatment resulted in an increased urea accumulation in the cortical space. This work demonstrates intra-renal functional assessment with hyperpolarized 13C-urea MRI in multi-papillary kidneys....

  11. Simultaneous hyperpolarized 13C-pyruvate MRI and 18F-FDG-PET in cancer (hyperPET)

    DEFF Research Database (Denmark)

    Gutte, Henrik; Hansen, Adam E.; Henriksen, Sarah T.

    2015-01-01

    named this concept hyper PET. Intravenous injection of the hyperpolarized 13C-pyruvate results in an increase of 13C-lactate, 13C-alanine and 13CCO2 (13C-HCO3) resonance peaks relative to the tissue, disease and the metabolic state probed. Accordingly, with dynamic nuclear polarization (DNP) and use......In this paper we demonstrate, for the first time, the feasibility of a new imaging concept - combined hyperpolarized 13C-pyruvate magnetic resonance spectroscopic imaging (MRSI) and 18F-FDG-PET imaging. This procedure was performed in a clinical PET/MRI scanner with a canine cancer patient. We have...... of 13C-pyruvate it is now possible to directly study the Warburg Effect through the rate of conversion of 13C-pyruvate to 13C-lactate. In this study, we combined it with 18F-FDG-PET that studies uptake of glucose in the cells. A canine cancer patient with a histology verified local recurrence...

  12. Visual assessment of functional lungs parenchyma on HRCT and 3He-MRI in patients after single lung transplantation: comparison with quantitative volumetric results

    International Nuclear Information System (INIS)

    Zaporozhan, J.; Ley, S.; Gast, K.K.; Heussel, C.P.; Thelen, M.; Biedermann, A.; Eberle, B.; Mayer, E.; Kauczor, H.U.

    2005-01-01

    Purpose: Visual assessment of the ventilation using HRCT and 3 He-MRI in patients after single lung transplantation (SLTX). Analysis of specific ventilation defects found with 3 He-MRI and morphological changes found with HRCT. Materials and Methods: We evaluated 8 male patients (54±6 years) suffering from emphysema and six patients (3 males and 3 females, 58±9.5 years) suffering from idiopathic pulmonary fibrosis (IPF) after SLTX. The morphological changes at HRCT were classified and localized. In 3 He-MRI (2D FLASH), 10 to 14 slices (slice thickness 10 mm, gap 5 mm) were acquired in coronal orientation to cover the whole lung. Ventilation defects were localized and characterized. The visually estimated ventilation was recorded on a 5-point scoring system. A double threshold technique was applied to volumetric quantification in 3 He-MRI to serve as internal reference. Results: We found no correlation between morphological changes in HRCT and ventilation defects in 3 He-MRI. The visual assessment of ventilation in 3 He-MRI was sufficient in patients with emphysema, but this was not confirmed in patients with IPF. The visual assessment in HRCT did not correlate with the volumetric evaluation in both conditions. Conclusion: The various ventilation defects were not linked to specific morphological changes. For the visually assessed ventilation in patients with emphysema, 3 He-MRI is superior to HRCT. (orig.)

  13. Infrared spectra of 4HeH+, 4HeD+, 3HeH+, and 3HeD+

    International Nuclear Information System (INIS)

    Crofton, M.W.; Altman, R.S.; Haese, N.N.; Oka, T.

    1989-01-01

    Isotopic species of the HeH + molecular ion provide an excellent testing ground for studying isotopic dependence of vibration--rotation constants because of the small masses of He and H isotopes. We have observed infrared spectra of the hot band v=2 left-arrow 1 of HeH + and fundamental bands of isotopic species HeD + , 3 HeH + , and 3 HeD + , and obtained the Dunham coefficients Y kl , and the isotopically independent parameters U kl , Δ He kl , and Δ H kl

  14. Hyperpolarized 3-helium MR imaging of the lungs: testing the concept of a central production facility

    International Nuclear Information System (INIS)

    Beek, E.J.R. van; Schmiedeskamp, J.; Filbir, F.; Heil, W.; Wolf, M.; Otten, E.; Wild, J.M.; Paley, M.N.J.; Fichele, S.; Woodhouse, N.; Swift, A.; Knitz, F.; Mills, G.H.

    2003-01-01

    The aim of this study was to test the feasibility of a central production facility with distribution network for implementation of hyperpolarized 3-helium MRI. The 3-helium was hyperpolarized to 50-65% using a large-scale production facility based at a university in Germany. Using a specially designed transport box, containing a permanent low-field shielded magnet and dedicated iron-free glass cells, the hyperpolarized 3-helium gas was transported via airfreight to a university in the UK. At this location, the gas was used to perform in vivo MR experiments in normal volunteers and patients with chronic obstructive lung diseases. Following initial tests, the transport (road-air-road cargo) was successfully arranged on six occasions (approximately once per month). The duration of transport to imaging averaged 18 h (range 16-20 h), which was due mainly to organizational issues such as working times and flight connections. During the course of the project, polarization at imaging increased from 20% to more than 30%. A total of 4 healthy volunteers and 8 patients with chronic obstructive pulmonary disease were imaged. The feasibility of a central production facility for hyperpolarized 3-helium was demonstrated. This should enable a wider distribution of gas for this novel technology without the need for local start-up costs. (orig.)

  15. Hyperpolarized [1-(13) C]pyruvate MRI for noninvasive examination of placental metabolism and nutrient transport: A feasibility study in pregnant guinea pigs.

    Science.gov (United States)

    Friesen-Waldner, Lanette J; Sinclair, Kevin J; Wade, Trevor P; Michael, Banoub; Chen, Albert P; de Vrijer, Barbra; Regnault, Timothy R H; McKenzie, Charles A

    2016-03-01

    To test the feasibility of hyperpolarized [1-(13) C]pyruvate magnetic resonance imaging (MRI) for noninvasive examination of guinea pig fetoplacental metabolism and nutrient transport. Seven pregnant guinea pigs with a total of 30 placentae and fetuses were anesthetized and scanned at 3T. T1 -weighted (1) H images were obtained from the maternal abdomen. An 80 mM solution of hyperpolarized [1-(13) C]pyruvate (hereafter referred to as pyruvate) was injected into a vein in the maternal foot. Time-resolved 3D (13) C images were acquired starting 10 seconds after the beginning of bolus injection and every 10 seconds after to 50 seconds. The pregnant guinea pigs were recovered after imaging. Regions of interest (ROIs) were drawn around the maternal heart and each placenta and fetal liver in all slices in the (1) H images. These ROIs were copied to the (13) C images and were used to calculate the sum of the pyruvate and lactate signal intensities for each organ. The signal intensities were normalized by the volume of the organ and the maximum signal in the maternal heart. No adverse events were observed in the pregnant guinea pigs and natural pupping occurred at term (∼68 days). Pyruvate signal was observed in all 30 placentae, and lactate, a by-product of pyruvate metabolism, was also observed in all placentae. The maximum pyruvate and lactate signals in placentae occurred at 20 seconds. In addition to the observation of pyruvate and lactate signals in the placentae, both pyruvate and lactate signals were observed in all fetal livers. The maximum pyruvate and lactate signals in the fetal livers occurred at 10 seconds and 20 seconds, respectively. This work demonstrates the feasibility of using hyperpolarized [1-(13) C]pyruvate MRI to noninvasively examine fetoplacental metabolism and transport of pyruvate in guinea pigs. Hyperpolarized (13) C MRI may provide a novel method for longitudinal studies of fetoplacental abnormalities. © 2015 Wiley Periodicals, Inc.

  16. Molecular MRI in the Earth's Magnetic Field Using Continuous Hyperpolarization of a Biomolecule in Water.

    Science.gov (United States)

    Rovedo, Philipp; Knecht, Stephan; Bäumlisberger, Tim; Cremer, Anna Lena; Duckett, Simon B; Mewis, Ryan E; Green, Gary G R; Burns, Michael; Rayner, Peter J; Leibfritz, Dieter; Korvink, Jan G; Hennig, Jürgen; Pütz, Gerhard; von Elverfeldt, Dominik; Hövener, Jan-Bernd

    2016-06-30

    In this work, we illustrate a method to continuously hyperpolarize a biomolecule, nicotinamide, in water using parahydrogen and signal amplification by reversible exchange (SABRE). Building on the preparation procedure described recently by Truong et al. [ J. Phys. Chem. B , 2014 , 118 , 13882 - 13889 ], aqueous solutions of nicotinamide and an Ir-IMes catalyst were prepared for low-field NMR and MRI. The (1)H-polarization was continuously renewed and monitored by NMR experiments at 5.9 mT for more than 1000 s. The polarization achieved corresponds to that induced by a 46 T magnet (P = 1.6 × 10(-4)) or an enhancement of 10(4). The polarization persisted, although reduced, if cell culture medium (DPBS with Ca(2+) and Mg(2+)) or human cells (HL-60) were added, but was no longer observable after the addition of human blood. Using a portable MRI unit, fast (1)H-MRI was enabled by cycling the magnetic field between 5 mT and the Earth's field for hyperpolarization and imaging, respectively. A model describing the underlying spin physics was developed that revealed a polarization pattern depending on both contact time and magnetic field. Furthermore, the model predicts an opposite phase of the dihydrogen and substrate signal after one exchange, which is likely to result in the cancelation of some signal at low field.

  17. Hyperpolarized 129Xe as an NMR probe for functional studies

    International Nuclear Information System (INIS)

    Wolber, J.

    2000-01-01

    The nuclear spin polarization of 129 Xe can be enhanced by several orders of magnitude using optical pumping techniques, resulting in a dramatic enhancement of the 129 Xe Nuclear Magnetic Resonance (NMR) signal. The 'hyperpolarized' gas can be used for Magnetic Resonance Imaging (MRI) of the void spaces of the lungs after introduction of the gas into the respiratory system. Furthermore, the high solubility of xenon in blood and lipids suggests the use of 129 Xe NMR for studying blood flow, permeability, perfusion and blood volume. Hyperpolarized 129 Xe MRI has the potential of combining the high sensitivity and functional information of radioactive tracer studies with the high spatial and temporal resolution of MRI. The spin-lattice relaxation time T 1 of 129 Xe in blood determines the loss of polarization during transit from the lungs to the tissue of interest. A difference in the relaxation times of xenon in oxygenated and deoxygenated blood could be used as a contrast mechanism in functional Magnetic Resonance Imaging (fMRI). In this thesis, the hyperpolarized 129 Xe T 1 in human blood is measured in vitro as a function of blood oxygenation, and the relevant relaxation mechanisms are discussed. A new and unexpected finding is that the hyperpolarized 129 Xe NMR spectrum in blood is highly sensitive to blood oxygenation. Therefore, hyperpolarized 129 Xe NMR provides a powerful means of measuring blood oxygenation quantitatively and non-invasively. The interaction of xenon with hemoglobin is responsible for an oxygen-dependent shift of the 129 Xe NMR resonance of xenon in red blood cells. Injection delivery of hyperpolarized 129 Xe in solution could be a more efficient method of administrating the gas for functional NMR studies. For this purpose, suitable biocompatible carrier media have been studied. In particular, the use of perfluorocarbon emulsions, which are already in use as blood substitutes, as delivery media for hyperpolarized 129 Xe has been investigates

  18. Rapid assessment of pulmonary gas transport with hyperpolarized 129Xe MRI using a 3D radial double golden-means acquisition with variable flip angles.

    Science.gov (United States)

    Ruppert, Kai; Amzajerdian, Faraz; Hamedani, Hooman; Xin, Yi; Loza, Luis; Achekzai, Tahmina; Duncan, Ian F; Profka, Harrilla; Siddiqui, Sarmad; Pourfathi, Mehrdad; Cereda, Maurizio F; Kadlecek, Stephen; Rizi, Rahim R

    2018-04-22

    To demonstrate the feasibility of using a 3D radial double golden-means acquisition with variable flip angles to monitor pulmonary gas transport in a single breath hold with hyperpolarized xenon-129 MRI. Hyperpolarized xenon-129 MRI scans with interleaved gas-phase and dissolved-phase excitations were performed using a 3D radial double golden-means acquisition in mechanically ventilated rabbits. The flip angle was either held fixed at 15 ° or 5 °, or it was varied linearly in ascending or descending order between 5 ° and 15 ° over a sampling interval of 1000 spokes. Dissolved-phase and gas-phase images were reconstructed at high resolution (32 × 32 × 32 matrix size) using all 1000 spokes, or at low resolution (22 × 22 × 22 matrix size) using 400 spokes at a time in a sliding-window fashion. Based on these sliding-window images, relative change maps were obtained using the highest mean flip angle as the reference, and aggregated pixel-based changes were tracked. Although the signal intensities in the dissolve-phase maps were mostly constant in the fixed flip-angle acquisitions, they varied significantly as a function of average flip angle in the variable flip-angle acquisitions. The latter trend reflects the underlying changes in observed dissolve-phase magnetization distribution due to pulmonary gas uptake and transport. 3D radial double golden-means acquisitions with variable flip angles provide a robust means for rapidly assessing lung function during a single breath hold, thereby constituting a particularly valuable tool for imaging uncooperative or pediatric patient populations. © 2018 International Society for Magnetic Resonance in Medicine.

  19. Dynamic coronary MR angiography in a pig model with hyperpolarized water

    DEFF Research Database (Denmark)

    Lipsø, Hans Kasper Wigh; Hansen, Esben Søvsø Szocska; Tougaard, Rasmus Stilling

    2018-01-01

    To investigate dynamic coronary MR angiography using hyperpolarized water as a positive contrast agent. Hyperpolarization can increase the signal by several orders of magnitude, and has recently been translated to human cardiac application. The aim was to achieve large 1 H signal enhancement...... to allow high-resolution imaging of the coronary arteries. Protons in D2 O were hyperpolarized by dissolution dynamic nuclear polarization. A total of 18 mL of hyperpolarized water was injected into the coronary arteries of healthy pigs (N = 9; 3 injections in 3 animals). The MRI images were acquired...... with a gradient-echo sequence in an oblique slab covering the main left coronary arteries with 0.55 mm in-plane resolution. The acquisition time was 870 ms per frame. A more than 200-fold signal enhancement compared with thermally polarized water at 3 T was obtained. Coronary angiographic images with a signal...

  20. 4-D segmentation and normalization of 3He MR images for intrasubject assessment of ventilated lung volumes

    Science.gov (United States)

    Contrella, Benjamin; Tustison, Nicholas J.; Altes, Talissa A.; Avants, Brian B.; Mugler, John P., III; de Lange, Eduard E.

    2012-03-01

    Although 3He MRI permits compelling visualization of the pulmonary air spaces, quantitation of absolute ventilation is difficult due to confounds such as field inhomogeneity and relative intensity differences between image acquisition; the latter complicating longitudinal investigations of ventilation variation with respiratory alterations. To address these potential difficulties, we present a 4-D segmentation and normalization approach for intra-subject quantitative analysis of lung hyperpolarized 3He MRI. After normalization, which combines bias correction and relative intensity scaling between longitudinal data, partitioning of the lung volume time series is performed by iterating between modeling of the combined intensity histogram as a Gaussian mixture model and modulating the spatial heterogeneity tissue class assignments through Markov random field modeling. Evaluation of the algorithm was retrospectively applied to a cohort of 10 asthmatics between 19-25 years old in which spirometry and 3He MR ventilation images were acquired both before and after respiratory exacerbation by a bronchoconstricting agent (methacholine). Acquisition was repeated under the same conditions from 7 to 467 days (mean +/- standard deviation: 185 +/- 37.2) later. Several techniques were evaluated for matching intensities between the pre and post-methacholine images with the 95th percentile value histogram matching demonstrating superior correlations with spirometry measures. Subsequent analysis evaluated segmentation parameters for assessing ventilation change in this cohort. Current findings also support previous research that areas of poor ventilation in response to bronchoconstriction are relatively consistent over time.

  1. Visual assessment of functional lungs parenchyma on HRCT and {sup 3}He-MRI in patients after single lung transplantation: comparison with quantitative volumetric results; Visuelle Abschaetzung der funktionellen Lungenanteile in der HRCT und {sup 3}He-MRT bei Patienten nach Einzel-Lungentransplantation: Vergleich mit der absoluten Volumetrie

    Energy Technology Data Exchange (ETDEWEB)

    Zaporozhan, J.; Ley, S. [Klinik und Poliklinik fuer Radiologie, Johannes Gutenberg-Univ. Mainz (Germany); DKFZ, E010 - Radiologie, Heidelberg (Germany); Gast, K.K.; Heussel, C.P.; Thelen, M. [Klinik und Poliklinik fuer Radiologie, Johannes Gutenberg-Univ. Mainz (Germany); Biedermann, A. [III. Medizinische Klinik und Poliklinik, Johannes Gutenberg-Univ. Mainz (Germany); Eberle, B. [Klinik und Poliklinik fuer Anaesthesiologie, Univ. und Inselspital Bern (Switzerland); Mayer, E. [Klinik und Poliklinik fuer Herz-, Thorax- und Gefaesschirurgie, Johannes Gutenberg-Univ. Mainz (Germany); Kauczor, H.U. [DKFZ, E010 - Radiologie, Heidelberg (Germany)

    2005-04-01

    Purpose: Visual assessment of the ventilation using HRCT and {sup 3}He-MRI in patients after single lung transplantation (SLTX). Analysis of specific ventilation defects found with {sup 3}He-MRI and morphological changes found with HRCT. Materials and Methods: We evaluated 8 male patients (54{+-}6 years) suffering from emphysema and six patients (3 males and 3 females, 58{+-}9.5 years) suffering from idiopathic pulmonary fibrosis (IPF) after SLTX. The morphological changes at HRCT were classified and localized. In {sup 3}He-MRI (2D FLASH), 10 to 14 slices (slice thickness 10 mm, gap 5 mm) were acquired in coronal orientation to cover the whole lung. Ventilation defects were localized and characterized. The visually estimated ventilation was recorded on a 5-point scoring system. A double threshold technique was applied to volumetric quantification in {sup 3}He-MRI to serve as internal reference. Results: We found no correlation between morphological changes in HRCT and ventilation defects in {sup 3}He-MRI. The visual assessment of ventilation in {sup 3}He-MRI was sufficient in patients with emphysema, but this was not confirmed in patients with IPF. The visual assessment in HRCT did not correlate with the volumetric evaluation in both conditions. Conclusion: The various ventilation defects were not linked to specific morphological changes. For the visually assessed ventilation in patients with emphysema, {sup 3}He-MRI is superior to HRCT. (orig.)

  2. Simultaneous hyperpolarized 13C-pyruvate MRI and 18F-FDG-PET in cancer (hyperPET)

    DEFF Research Database (Denmark)

    Borgwardt, Henrik Gutte; Hansen, Adam Espe; Henriksen, Sarah T.

    2015-01-01

    have named this concept hyper PET. Intravenous injection of the hyperpolarized (13)C-pyruvate results in an increase of (13)C-lactate, (13)C-alanine and (13)C-CO2 ((13)C-HCO3) resonance peaks relative to the tissue, disease and the metabolic state probed. Accordingly, with dynamic nuclear polarization......In this paper we demonstrate, for the first time, the feasibility of a new imaging concept - combined hyperpolarized (13)C-pyruvate magnetic resonance spectroscopic imaging (MRSI) and (18)F-FDG-PET imaging. This procedure was performed in a clinical PET/MRI scanner with a canine cancer patient. We...... (DNP) and use of (13)C-pyruvate it is now possible to directly study the Warburg Effect through the rate of conversion of (13)C-pyruvate to (13)C-lactate. In this study, we combined it with (18)F-FDG-PET that studies uptake of glucose in the cells. A canine cancer patient with a histology verified...

  3. Detection of tobacco smoke deposition by hyperpolarized krypton-83 MRI.

    Science.gov (United States)

    Cleveland, Zackary I; Pavlovskaya, Galina E; Stupic, Karl F; Wooten, Jan B; Repine, John E; Meersmann, Thomas

    2008-02-01

    Despite the importance of the tobacco smoke particulate matter in the lungs to the etiology of pulmonary disease in cigarette smokers, little is currently known about the spatial distribution of particle deposition or the persistence of the resulting deposits in humans, and no satisfactory technique currently exists to directly observe tobacco smoke condensate in airways. In this proof-of-principle work, hyperpolarized (hp) 83Kr MRI and NMR spectroscopy are introduced as probes for tobacco smoke deposition in porous media. A reduction in the hp-83Kr longitudinal (T1) relaxation of up to 95% under near-ambient humidity, pressure and temperature conditions was observed when the krypton gas was brought into contact with surfaces that had been exposed to cigarette smoke. This smoke-induced acceleration of the 83Kr self-relaxation was observed for model glass surfaces that, in some experiments, were coated with bovine lung surfactant extract. However, a similar effect was not observed with hp-(129)Xe indicating that the 83Kr sensitivity to smoke deposition was not caused by paramagnetic species but rather by quadrupolar relaxation due to high adsorption affinity for the smoke deposits. The 83Kr T1 differences between smoke-treated and untreated surfaces were sufficient to produce a strong contrast in variable flip angle FLASH hp-83Kr MRI, suggesting that hp-83Kr may be a promising contrast agent for in vivo pulmonary MRI.

  4. Sub-Coulomb 3He transfer and its use to extract three-particle asymptotic normalization coefficients

    Science.gov (United States)

    Avila, M. L.; Baby, L. T.; Belarge, J.; Keeley, N.; Kemper, K. W.; Koshchiy, E.; Kuchera, A. N.; Rogachev, G. V.; Rusek, K.; Santiago-Gonzalez, D.

    2018-01-01

    Data for the 13C(6Li,t )16O reaction, obtained in inverse kinematics at a 13C incident energy of 7.72 MeV, are presented. A distorted wave Born approximation (DWBA) analysis was used to extract spectroscopic factors and asymptotic normalization coefficients (ANCs) for the 〈" close="〉6Li∣3He +3H 〉">16O∣13C +3He overlaps, subject to the assumption of a fixed ANCs as a function of various inputs to the DWBA calculations was explored. The extracted ANCs were found to vary as a cubic function of the radius of the potential well binding the transferred 3He to the 13C core while the spectroscopic factors varied as a quartic function of the radius. The ANC values could be determined to within a factor of two for this system.

  5. Observation of the Rotational Spectra of 4HeH+, 4HeD+, 3HeH+, and 3HeD+

    International Nuclear Information System (INIS)

    Matsushima, F.; Oka, T.; Takagi, K.

    1997-01-01

    Low J rotational transitions of 4 HeH + , 4 HeD + , 3 HeH + , and 3 HeD + were observed in the 2 endash 5THz region with a high-precision far-infrared spectrometer. Dunham coefficients Y kl and isotopically independent parameters U kl , Δ He kl , and Δ H kl were determined. In particular, Δ parameters with k=0 and l=1,2 were determined with unprecedented accuracy, and provide important information for breakdown of the Born-Oppenheimer approximation. The lowest J=1 left-arrow 0 transition of 4 HeH + observed at 2010.1839(2)GHz will be an important future probe for detecting this species in space. copyright 1997 The American Physical Society

  6. ROVIBRATIONAL QUENCHING RATE COEFFICIENTS OF HD IN COLLISIONS WITH He

    International Nuclear Information System (INIS)

    Nolte, J. L.; Stancil, P. C.; Lee, T.-G.; Balakrishnan, N.; Forrey, R. C.

    2012-01-01

    Along with H 2 , HD has been found to play an important role in the cooling of the primordial gas for the formation of the first stars and galaxies. It has also been observed in a variety of cool molecular astrophysical environments. The rate of cooling by HD molecules requires knowledge of collisional rate coefficients with the primary impactors, H, He, and H 2 . To improve knowledge of the collisional properties of HD, we present rate coefficients for the He-HD collision system over a range of collision energies from 10 –5 to 5 × 10 3 cm –1 . Fully quantum mechanical scattering calculations were performed for initial HD rovibrational states of j = 0 and 1 for v = 0-17 which utilized accurate diatom rovibrational wave functions. Rate coefficients of all Δv = 0, –1, and –2 transitions are reported. Significant discrepancies with previous calculations, which adopted a small basis and harmonic HD wave functions for excited vibrational levels, were found for the highest previously considered vibrational state of v = 3. Applications of the He-HD rate coefficients in various astrophysical environments are briefly discussed.

  7. Development of a hyperpolarized 129Xe system on 3T for the rat lungs

    International Nuclear Information System (INIS)

    Sato, Hiroshi; Enmi, Jun-ichiro; Hayashi, Takuya

    2004-01-01

    MRI (magnetic resonance imaging) with 129 Xe has gained much attention as a diagnostic methodology because of its affinity for lipids and possible polarization. The quantitative estimation of net detectability and stability of hyperpolarized 129 Xe in the dissolved phase in vivo is valuable to the development of clinical applications. The goal of this study was to develop a stable hyperpolarized 129 Xe experimental 3T system to statistically analyze the dissolved-phase 129 Xe signal in the rat lungs. The polarization of 129 Xe with buffer gases at the optical pumping cell was measured under adiabatic fast passage against the temperature of an oven and laser absorption at the cell. The gases were insuffiated into the lungs of Sprague-Dawley rats (n=15, 400-550 g) through an endotracheal tube under spontaneous respiration. Frequency-selective spectroscopy was performed for the gas phase and dissolved phase. We analyzed the 129 Xe signal in the dissolved phase to measure the chemical shift, T 2 * , delay and its ratio in a rat lungs on 3T. The polarizer was able to produce polarized gas (1.1±0.47%, 120 cm 3 ) hundreds of times with the laser absorption ratio (25%) kept constant at the cell. The optimal buffer gas ratio of 25-50% rendered the maximum signal in the dissolved phase. Two dominant peaks of 211.8±0.9 and 201.1±0.6 ppm were observed with a delay of 0.4±0.9 and 0.9±1.0 s from the gas phase spectra. The ratios of their average signal to that of the gas phase were 5.6±5.2% and 4.4±4.7%, respectively. The T 2 * of the air space in the lungs was 2.5±0.5 ms, which was 3.8 times shorter than that in a syringe. We developed a hyperpolarized 129 Xe experimental system using a 3T MRI scanner that yields sufficient volume and polarization and quantitatively analyzed the dissolved-phase 129 Xe signal in the rat lungs. (author)

  8. NMR and MRI of continuously dissolved hyperpolarized {sup 129}Xe by means of hollow fibers

    Energy Technology Data Exchange (ETDEWEB)

    Amor, Nadia; Kueppers, Markus; Bluemich, Bernhard [ITMC of RWTH Aachen University (Germany); Hamilton, Kathrin; Schmitz-Rode, Thomas; Steinseifer, Ulrich [HIA of RWTH Aachen University (Germany); Appelt, Stephan [Research Center Juelich (Germany)

    2011-07-01

    Various methods of hyperpolarizing (HP) spin systems have been developed during the last years to increase the intrinsically low sensitivity of NMR by several orders of magnitude. Among them is the hyperpolarization of {sup 129}Xe via Spin Exchange Optical Pumping (SEOP). NMR of HP {sup 129}Xe is of great interest because of its good solubility and its very sensitive chemical shift. The main obstacle for many applications is the efficient and continuous dissolution into carrier agents without formation of foams or bubbles. It has been overcome by the so-called ''xenonizer'' setups. They mainly consist of commercially available hollow fiber membranes typically used in clinical oxygenators. A purpose-built xenonizer setup has been developed and analyzed in detail by NMR spectroscopy and MRI for varying fiber materials as well as for different fluids, including bio-relevant fluids such as blood, plasma, and erythrocytes. As a result, the xenonizer technology could be further understood and improved, and new applications of HP {sup 129}Xe for medical NMR were explored.

  9. Novel methods and applications of NMR and MRI. Low-power RF excitation and hyperpolarized Xenon-129

    International Nuclear Information System (INIS)

    Amor, Nadia

    2012-01-01

    Since their discovery in the middle of the last century, Nuclear Magnetic Resonance (NMR) and Magnetic Resonance Imaging (MRI) have become an important and very versatile tool in industry, medicine, and basic research. The aim of this work is to explore possible improvements and new applications of NMR methods. First, a recently introduced excitation NMR pulse sequence, termed Frank sequence excitation, which allows for significant reduction of rf-excitation power, is systematically analyzed and compared to conventional NMR in detail. Furthermore, its feasibility for MRI is investigated and advantages as well as drawbacks in comparison to standard MRI are discussed. The second part focuses on new biomedical applications of hyperpolarized (HP) 129 Xe which not only offers a signal enhancement of several orders of magnitude but also provides new contrast mechanisms. A setup for continuous dissolution of HP 129 Xe gas into blood and other fluids is optimized and analyzed quantitatively by NMR and MRI. On the basis of these results, blood-dissolved HP 129 Xe is used to investigate blood-gas dynamics, as well as the rheological behavior of blood.

  10. A novel MR contrast agent for angiography and perfusion: Hyperpolarized water

    DEFF Research Database (Denmark)

    Lipsø, Hans Kasper Wigh

    , hyperpolarized by dissolution Dynamic Nuclear Polarization (d-DNP), can be applied as an MRI contrast agent for angiography and perfusion. The first part of the project focuses on development of a protocol for production of large samples of hyperpolarized protons in D2O. The samples are polarized and dissolved...

  11. He3 cryostat

    International Nuclear Information System (INIS)

    Novichkova, L.G.; Kulikov, Yu.V.; Stashkova, N.M.

    1992-01-01

    An effective cryostat featuring a one-cycle He 3 refrigerator with a cryosorption pump is described. Gaseous He 3 in contained in a low-pressure vessel having a common wall with a liquid N 2 bath. Due to this, the gas is cooled before sorption and the sorption rate increases approximately by a factor of ten. The cryostat is provided with a needle valve which cuts off the ballast volume of the pipelines from the refrigerator. As a result, the pressure of He 3 vapours increases before condensation and with refrigerator dimensions selected properly, the liquefaction coefficient reaches approximately 80%. Test results of the cryostat and its specifications are presented. (Author)

  12. Spin waves at the liquid 3He-4He interface

    International Nuclear Information System (INIS)

    Heff, A.; Candela, D.; Edwards, D.O.; Kumar, S.

    1987-01-01

    The properties of various interfaces in helium and, in particular, the interface between liquid 3 He and a solution of 3 He in 4 He, may be studied using spin waves. Assuming no transverse relaxation, the boundary condition for the transverse magnetization contains one complex kinetic coefficient, b. For the normal 3 He to 3 He- 4 He interface, b is related to the 3 He quasi-particle transmission probability antiτ, which we estimate from a simple model. A calculation of the spin wave absorption spectrum for a typical geometry shows that b and antiτ may be measured by NMR. Neither b nor antiτ is greatly affected when the pure 3 He enters the A phase, but both are strongly reduced in the B phase

  13. Novel methods and applications of NMR and MRI. Low-power RF excitation and hyperpolarized Xenon-129

    Energy Technology Data Exchange (ETDEWEB)

    Amor, Nadia

    2012-07-01

    Since their discovery in the middle of the last century, Nuclear Magnetic Resonance (NMR) and Magnetic Resonance Imaging (MRI) have become an important and very versatile tool in industry, medicine, and basic research. The aim of this work is to explore possible improvements and new applications of NMR methods. First, a recently introduced excitation NMR pulse sequence, termed Frank sequence excitation, which allows for significant reduction of rf-excitation power, is systematically analyzed and compared to conventional NMR in detail. Furthermore, its feasibility for MRI is investigated and advantages as well as drawbacks in comparison to standard MRI are discussed. The second part focuses on new biomedical applications of hyperpolarized (HP) {sup 129}Xe which not only offers a signal enhancement of several orders of magnitude but also provides new contrast mechanisms. A setup for continuous dissolution of HP {sup 129}Xe gas into blood and other fluids is optimized and analyzed quantitatively by NMR and MRI. On the basis of these results, blood-dissolved HP {sup 129}Xe is used to investigate blood-gas dynamics, as well as the rheological behavior of blood.

  14. Thermodynamic properties of 3He--4He mixtures near Tlambda

    International Nuclear Information System (INIS)

    Kakizaki, A.; Satoh, T.

    1976-01-01

    In order to investigate 3 He impurity effects on the superfluid transition, measurements were made on the thermodynamic quantities, specific heat, thermal expansion coefficients, and pressure dependence of the lambda-transition temperature of three 3 He-- 4 He mixtures and pure 4 He in the neighborhood of the lambda-transition temperature under their saturated vapor pressure. Making use of these measured quantities, it is shown that the so-called Pippard--Buckingham--Fairbank relation holds for 3 He-- 4 He mixtures as well as for pure 4 He, at least in the temperature region of 10 -4 K less than or equal to absolute value (T - T/sub lambda/) less than or equal to 10 -2 K. Based on this, the 3 He impurity effects on the behavior of the specific heat near the lambda-transition are discussed

  15. Homogeneous nucleation in phase separation of solid 3He-4He mixtures

    International Nuclear Information System (INIS)

    Poole, M.; Smith, A.; Maidanov, V.A.; Rudavskii, E.Ya.; Grigor'ev, V.N.; Slezov, V.V.; Saunders, J.; Cowan, B.

    2003-01-01

    NMR and pressure have been measured during phase separation in solid 3 He- 4 He mixtures. Spin echoes were used to observe bounded diffusion and to estimate the diffusion coefficient, size and nuclei concentration in the 3 He-enriched phase. The characteristic phase separation time constant of the mixture was found from pressure measurements. The results argue convincingly for homogeneous nucleation. The surface tension of the nuclei is found independently from NMR and from pressure measurements; the two determinations agree well and yield a surface tension coefficient of 4.9x10 -6 J m -2

  16. Passive shimming of the fringe field of a superconducting magnet for ultra-low field hyperpolarized noble gas MRI.

    Science.gov (United States)

    Parra-Robles, Juan; Cross, Albert R; Santyr, Giles E

    2005-05-01

    Hyperpolarized noble gases (HNGs) provide exciting possibilities for MR imaging at ultra-low magnetic field strengths (superconductive magnets used in clinical MR imaging can provide a stable magnetic field for this purpose. In addition to offering the benefit of HNG MR imaging alongside conventional high field proton MRI, this approach offers the other useful advantage of providing different field strengths at different distances from the magnet. However, the extremely strong field gradients associated with the fringe field present a major challenge for imaging since impractically high active shim currents would be required to achieve the necessary homogeneity. In this work, a simple passive shimming method based on the placement of a small number of ferromagnetic pieces is proposed to reduce the fringe field inhomogeneities to a level that can be corrected using standard active shims. The method explicitly takes into account the strong variations of the field over the volume of the ferromagnetic pieces used to shim. The method is used to obtain spectra in the fringe field of a high-field (1.89 T) superconducting magnet from hyperpolarized 129Xe gas samples at two different ultra-low field strengths (8.5 and 17 mT). The linewidths of spectra measured from imaging phantoms (30 Hz) indicate a homogeneity sufficient for MRI of the rat lung.

  17. Mis-estimation and bias of hyperpolarized apparent diffusion coefficient measurements due to slice profile effects.

    Science.gov (United States)

    Gordon, Jeremy W; Milshteyn, Eugene; Marco-Rius, Irene; Ohliger, Michael; Vigneron, Daniel B; Larson, Peder E Z

    2017-09-01

    The purpose of this work was to explore the impact of slice profile effects on apparent diffusion coefficient (ADC) mapping of hyperpolarized (HP) substrates. Slice profile effects were simulated using a Gaussian radiofrequency (RF) pulse with a variety of flip angle schedules and b-value ordering schemes. A long T 1 water phantom was used to validate the simulation results, and ADC mapping of HP [ 13 C, 15 N 2 ]urea was performed on the murine liver to assess these effects in vivo. Slice profile effects result in excess signal after repeated RF pulses, causing bias in HP measurements. The largest error occurs for metabolites with small ADCs, resulting in up to 10-fold overestimation for metabolites that are in more-restricted environments. A mixed b-value scheme substantially reduces this bias, whereas scaling the slice-select gradient can mitigate it completely. In vivo, the liver ADC of hyperpolarized [ 13 C, 15 N 2 ]urea is nearly 70% lower (0.99 ± 0.22 vs 1.69 ± 0.21 × 10 -3 mm 2 /s) when slice-select gradient scaling is used. Slice profile effects can lead to bias in HP ADC measurements. A mixed b-value ordering scheme can reduce this bias compared to sequential b-value ordering. Slice-select gradient scaling can also correct for this deviation, minimizing bias and providing more-precise ADC measurements of HP substrates. Magn Reson Med 78:1087-1092, 2017. © 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.

  18. Temperature dependence of He(2 3PJ) reactions: Collision-induced mixing and conversion to He2( 3Πg) molecules

    International Nuclear Information System (INIS)

    Zhao, X.; Soletsky, P.A.; Bryan, W.H.; Dunning, F.B.; Walters, G.K.

    1993-01-01

    The rate coefficients for mixing between He(2 3 P J, MJ) levels during collisions with ground-state helium atoms and for conversion of He(2 3 P J ) atoms to He 2 (b 3 Π g ) molecules via three-body reactions in helium gas have been investigated over the temperature range 1.6--300 K. The measured rate coefficients for collisionally induced P-state mixing decrease slowly with decreasing temperature, from (1.8±0.5)x10 -9 cm 3 s -1 at 300 K to (4.5±0.5)x10 -10 cm 3 s -1 at 4.2 K. The rate coefficients for the production of He 2 (b 3 Π g ) molecules via three-body reactions are observed to increase with decreasing temperature and are described by the relation k P congruent(2.5+267T -1 )x10 -32 cm 6 s -1 . This behavior, which is very different from that noted in earlier studies of the conversion of He(2 3 S 1 ) atoms to He 2 (a 3 Σ u + ) molecules through three-body reactions, suggests that the reaction is not thermally activated

  19. Heat pulses in dilute 3He-4He mixtures

    International Nuclear Information System (INIS)

    Husson, L.P.J.

    1983-01-01

    The propagation of heat pulses in dilute 3 He- 4 He mixtures under pressure along a tube, which is long compared to its diameter, is discussed. At high temperatures, where the excitations are in local equilibrium with one another, the propagation of heat pulses in the liquid is determined by the phenomenon of second sound, which is essentially a density wave in the excitation gas. The velocity and attenuation of second sound can be determined from the shape of the transmitted pulse. Measurements on the scattering and absorption of phonons are presented, together with a detailed description of the experimental technique and the electronic equipment. Measurements on the velocity and absorption of second sound are presented. From the results for the velocity of second sound in pure 4 He, values of the phonon and roton parameters are deduced. The velocity data in the mixtures have been used to calculate values of the effective mass of 3 He in superfluid 4 He. The results of these calculations have been compared with values of the effective mass obtained by other authors. The coefficient of second-sound absorption in pure 4 He is computed from theory, making use of the phonon and roton parameters calculated from the second-sound velocity data in pure 4 He. The experimental results on the scattering and absorption of phonons have been analysed. The empirical expressions for the scattering and absorption rates obtained from the diffusive phonon signals were compared with the results of the Baym-Ebner theory, and have also been used to calculate the coefficient of thermal conductivity in dilute 3 He- 4 He mixtures. (Auth.)

  20. Bulk damping of sound in superfluid 3He--4He under stagnation of the normal component

    International Nuclear Information System (INIS)

    Karchava, T.A.; Sanikidze, D.G.; Chkhaidze, N.D.

    1983-01-01

    The propagation of waves in superfluid 3 He-- 4 He solutions is considered under partial stagnation of the normal component. The wave processes in capillaries are presented as a superposition of the first sound, second sound, and viscous and diffusion waves. The damping coefficients are calculated for the modified first sound and for the thermal wave in superfluid 3 He-- 4 He solutions and related to the viscosity, thermal conductivity, diffusion, barodiffusion, and thermodiffusion coefficients

  1. Nonlinear second- and first-sound wave equations in 3He-4He mixtures

    International Nuclear Information System (INIS)

    Mohazzab, Masoud; Mulders, Norbert

    2000-01-01

    We derive nonlinear Burgers equations for first and second sound in mixtures of 3 He- 4 He, using a reductive perturbation method and obtain expressions for the nonlinear and dissipation coefficients. We further find a diffusion equation for a coupled temperature-concentration mode. The amplitude of first (second) sound generated from second (first) sound in mixtures is also derived. Our derivation includes the dependence of thermodynamical quantities on temperature, pressure, and 3 He concentration, and is valid up to a first order in terms of the isobaric expansion coefficient. We show that close to the λ line the nonlinearity of second sound in mixtures is enhanced as compared with pure 4 He

  2. Comparison of air space measurement imaged by CT, small-animal CT, and hyperpolarized Xe MRI

    Science.gov (United States)

    Madani, Aniseh; White, Steven; Santyr, Giles; Cunningham, Ian

    2005-04-01

    Lung disease is the third leading cause of death in the western world. Lung air volume measurements are thought to be early indicators of lung disease and markers in pharmaceutical research. The purpose of this work is to develop a lung phantom for assessing and comparing the quantitative accuracy of hyperpolarized xenon 129 magnetic resonance imaging (HP 129Xe MRI), conventional computed tomography (HRCT), and highresolution small-animal CT (μCT) in measuring lung gas volumes. We developed a lung phantom consisting of solid cellulose acetate spheres (1, 2, 3, 4 and 5 mm diameter) uniformly packed in circulated air or HP 129Xe gas. Air volume is estimated based on simple thresholding algorithm. Truth is calculated from the sphere diameters and validated using μCT. While this phantom is not anthropomorphic, it enables us to directly measure air space volume and compare these imaging methods as a function of sphere diameter for the first time. HP 129Xe MRI requires partial volume analysis to distinguish regions with and without 129Xe gas and results are within %5 of truth but settling of the heavy 129Xe gas complicates this analysis. Conventional CT demonstrated partial-volume artifacts for the 1mm spheres. μCT gives the most accurate air-volume results. Conventional CT and HP 129Xe MRI give similar results although non-uniform densities of 129Xe require more sophisticated algorithms than simple thresholding. The threshold required to give the true air volume in both HRCT and μCT, varies with sphere diameters calling into question the validity of thresholding method.

  3. Gradient-induced longitudinal relaxation of hyperpolarized noble gases in the fringe fields of superconducting magnets used for magnetic resonance.

    Science.gov (United States)

    Zheng, Wangzhi; Cleveland, Zackary I; Möller, Harald E; Driehuys, Bastiaan

    2011-02-01

    When hyperpolarized noble gases are brought into the bore of a superconducting magnet for magnetic resonance imaging (MRI) or spectroscopy studies, the gases must pass through substantial field gradients, which can cause rapid longitudinal relaxation. In this communication, we present a means of calculating this spatially dependent relaxation rate in the fringe field of typical magnets. We then compare these predictions to experimental measurements of (3)He relaxation at various positions near a medium-bore 2-T small animal MRI system. The calculated and measured relaxation rates on the central axis of the magnet agree well and show a maximum (3)He relaxation rate of 3.83×10(-3) s(-1) (T(1)=4.4 min) at a distance of 47 cm from the magnet isocenter. We also show that if this magnet were self-shielded, its minimum T(1) would drop to 1.2 min. In contrast, a typical self-shielded 1.5-T clinical MRI scanner will induce a minimum on-axis T(1) of 12 min. Additionally, we show that the cylindrically symmetric fields of these magnets enable gradient-induced relaxation to be calculated using only knowledge of the on-axis longitudinal field, which can either be measured directly or calculated from a simple field model. Thus, while most MRI magnets employ complex and proprietary current configurations, we show that their fringe fields and the resulting gradient-induced relaxation are well approximated by simple solenoid models. Finally, our modeling also demonstrates that relaxation rates can increase by nearly an order of magnitude at radial distances equivalent to the solenoid radius. Copyright © 2010 Elsevier Inc. All rights reserved.

  4. Hyperpolarized 2-oxoglutarate as metabolic agent in mr

    DEFF Research Database (Denmark)

    2015-01-01

    Hyperpolarized 1-13C-2-oxoglutarate as contrast agent in13C Magnetic Resonance diagnostic technique (13C-MRI) for use in the diagnosis of cancer. In particular, upon administration of said 1-13C-2-oxoglutarate, signals of 1-13C-glutamate are detected. More in particular, different MR signals from13...

  5. Application of the three-body model to the reactions 6Li(3He,t 3He)3He and 6Li(3He,3He3He)3H

    International Nuclear Information System (INIS)

    Haftel, M.I.; Allas, R.G.; Beach, L.A.; Bondelid, R.O.; Petersen, E.L.; Slaus, I.; Lambert, J.M.; Treado, P.A.

    1977-01-01

    Experimental and theoretical cross sections are presented for the 6 Li( 3 He, 3 He 3 He) 3 H and 6 Li( 3 He,t 3 He) 3 He reactions for the symmetric angle pairs 20 0 -20 0 , 28.3 0 -28.3 0 , and 35 0 -35 0 . The theoretical cross sections are calculated in a three-body model where the trions (i.e., mass-3 nuclei) are treated as elementary particles with 6 Li being a 3 He- 3 H bound state. The trion-trion interaction is represented by S wave separable potentials with the breakup cross sections calculated with the tree-body Haftel-Ebenhoeh code. the Coulomb interaction is taken into account by fitting the separable potential parameters to the trion-trion scattering data and is included approximately in the breakup code. The experimental cross sections are compared with both the plane-wave impulse approximation and the three-body model predictions. The plane-wave impulse approximation predicts both the shapes and magnitudes poorly (10 to 20 times experiment). Without Coulomb corrections the three-body model gives good agreement with experiment for the shapes of the spectra with the magnitudes generally being about 40% of experiment for 6 Li( 3 He, 3 He 3 He) 3 H and about 80% for 6 Li( 3 He,t 3 He) 3 He. The Coulomb corrections improve the magnitudes predicted by the three-body model but not the shapes. It is observed that for these reactions S wave separable potentials describe the breakup data much better than they do the two-body trion-trion scattering data. This result should encourage further three-body treatment of these and similar reactions

  6. Signal to noise comparison of metabolic imaging methods on a clinical 3T MRI

    DEFF Research Database (Denmark)

    Müller, C. A.; Hansen, Rie Beck; Skinner, J. G.

    MRI with hyperpolarized tracers has enabled new diagnostic applications, e.g. metabolic imaging in cancer research. However, the acquisition of the transient, hyperpolarized signal with spatial and frequency resolution requires dedicated imaging methods. Here, we compare three promising candidate...... for 2D MR spectroscopic imaging (MRSI): (i) multi-echo balanced steady-state free precession (me-bSSFP), 1,2 (ii) echo planar spectroscopic imaging (EPSI) sequence and (iii) phase-encoded, pulseacquisition chemical-shift imaging (CSI)...

  7. Ion permeabilities in mouse sperm reveal an external trigger for SLO3-dependent hyperpolarization.

    Directory of Open Access Journals (Sweden)

    Julio C Chávez

    Full Text Available Unlike most cells of the body which function in an ionic environment controlled within narrow limits, spermatozoa must function in a less controlled external environment. In order to better understand how sperm control their membrane potential in different ionic conditions, we measured mouse sperm membrane potentials under a variety of conditions and at different external K(+ concentrations, both before and after capacitation. Experiments were undertaken using both wild-type, and mutant mouse sperm from the knock-out strain of the sperm-specific, pH-sensitive, SLO3 K(+ channel. Membrane voltage data were fit to the Goldman-Hodgkin-Katz equation. Our study revealed a significant membrane permeability to both K(+ and Cl(- before capacitation, as well as Na(+. The permeability to both K(+ and Cl(- has the effect of preventing large changes in membrane potential when the extracellular concentration of either ion is changed. Such a mechanism may protect against undesired shifts in membrane potential in changing ionic environments. We found that a significant portion of resting membrane potassium permeability in wild-type sperm was contributed by SLO3 K(+ channels. We also found that further activation of SLO3 channels was the essential mechanism producing membrane hyperpolarization under two separate conditions, 1 elevation of external pH prior to capacitation and 2 capacitating conditions. Both conditions produced a significant membrane hyperpolarization in wild-type which was absent in SLO3 mutant sperm. Hyperpolarization in both conditions may result from activation of SLO3 channels by raising intracellular pH; however, demonstrating that SLO3-dependent hyperpolarization is achieved by an alkaline environment alone shows that SLO3 channel activation might occur independently of other events associated with capacitation. For example sperm may undergo stages of membrane hyperpolarization when reaching alkaline regions of the female genital tract

  8. Imaging regional metabolic changes in the ischemic rat heart in vivo using hyperpolarized(1-13C)Pyruvate

    DEFF Research Database (Denmark)

    Lauritzen, Mette Hauge; Magnusson, Peter; Laustsen, Christoffer

    2017-01-01

    in the in vivo rat heart in an open-chest model of ischemia reperfusion. Hyperpolarized MRI enables new possibilities for evaluating changes in cardiac metabolism noninvasively and in real time, which potentially could be used for research to evaluate new treatments and metabolic interventions for myocardial......We evaluated the use of hyperpolarized 13C magnetic resonance imaging (MRI) in an open-chest rat model of myocardial infarction to image regional changes in myocardial metabolism. In total, 10 rats were examined before and after 30 minutes of occlusion of the left anterior descending coronary...

  9. Pulmonary hyperpolarized (129) Xe morphometry for mapping xenon gas concentrations and alveolar oxygen partial pressure: Proof-of-concept demonstration in healthy and COPD subjects.

    Science.gov (United States)

    Ouriadov, A; Farag, A; Kirby, M; McCormack, D G; Parraga, G; Santyr, G E

    2015-12-01

    Diffusion-weighted (DW) hyperpolarized (129) Xe morphometry magnetic resonance imaging (MRI) can be used to map regional differences in lung tissue micro-structure. We aimed to generate absolute xenon concentration ([Xe]) and alveolar oxygen partial pressure (pA O2 ) maps by extracting the unrestricted diffusion coefficient (D0 ) of xenon as a morphometric parameter. In this proof-of-concept demonstration, morphometry was performed using multi b-value (0, 12, 20, 30 s/cm(2) ) DW hyperpolarized (129) Xe images obtained in four never-smokers and four COPD ex-smokers. Morphometric parameters and D0 maps were computed and the latter used to generate [Xe] and pA O2 maps. Xenon concentration phantoms estimating a range of values mimicking those observed in vivo were also investigated. Xenon D0 was significantly increased (P = 0.035) in COPD (0.14 ± 0.03 cm(2) /s) compared with never-smokers (0.12 ± 0.02 cm(2) /s). COPD ex-smokers also had significantly decreased [Xe] (COPD = 8 ± 7% versus never-smokers = 13 ± 8%, P = 0.012) and increased pA O2 (COPD = 18 ± 3% versus never-smokers = 15 ± 3%, P = 0.009) compared with never-smokers. Phantom measurements showed the expected dependence of D0 on [Xe] over the range of concentrations anticipated in vivo. DW hyperpolarized (129) Xe MRI morphometry can be used to simultaneously map [Xe] and pA O2 in addition to providing micro-structural biomarkers of emphysematous destruction in COPD. Phantom measurements of D0 ([Xe]) supported the hypotheses that differences in subjects may reflect differences in functional residual capacity. © 2014 Wiley Periodicals, Inc.

  10. Mass diffusion coefficient measurement for vitreous humor using FEM and MRI

    Science.gov (United States)

    Rattanakijsuntorn, Komsan; Penkova, Anita; Sadha, Satwindar S.

    2018-01-01

    In early studies, the ‘contour method’ for determining the diffusion coefficient of the vitreous humor was developed. This technique relied on careful injection of an MRI contrast agent (surrogate drug) into the vitreous humor of fresh bovine eyes, and tracking the contours of the contrast agent in time. In addition, an analytical solution was developed for the theoretical contours built on point source model for the injected surrogate drug. The match between theoretical and experimental contours as a least square fit, while floating the diffusion coefficient, led to the value of the diffusion coefficient. This method had its limitation that the initial injection of the surrogate had to be spherical or ellipsoidal because of the analytical result based on the point-source model. With a new finite element model for the analysis in this study, the technique is much less restrictive and handles irregular shapes of the initial bolus. The fresh bovine eyes were used for drug diffusion study in the vitreous and three contrast agents of different molecular masses: gadolinium-diethylenetriaminepentaacetic acid (Gd-DTPA, 938 Da), non-ionic gadoteridol (Prohance, 559 Da), and bovine albumin conjugated with gadolinium (Galbumin, 74 kDa) were used as drug surrogates to visualize the diffusion process by MRI. The 3D finite element model was developed to determine the diffusion coefficients of these surrogates with the images from MRI. This method can be used for other types of bioporous media provided the concentration profile can be visualized (by methods such as MRI or fluorescence).

  11. Polarization transfer in the 3H(rvec p,rvec n)3He reaction and the 0- level in 4He

    International Nuclear Information System (INIS)

    Walston, J.R.; Gould, C.R.; Haase, D.G.; Raichle, B.W.; Seely, M.L.; Walston, J.R.; Keith, C.D.; Gould, C.R.; Haase, D.G.; Raichle, B.W.; Seely, M.L.; Tornow, W.; Wilburn, W.S.; Keith, C.D.; Tornow, W.; Wilburn, W.S.; Hoffmann, G.W.; Penttilae, S.I.

    1998-01-01

    Longitudinal polarization-transfer coefficients for the 3 H(rvec p,rvec n) 3 He reaction have been measured at zero degrees for proton energies of 1.3 endash 2.8 MeV. The results show a striking resonance behavior for energies corresponding to excitation of the 0 - level in 4 He at 21.0 MeV. In agreement with R-matrix calculations, the value approaches unity at 1.52 MeV, the peak of the resonance. Near this same energy, at 1.62 MeV, the transverse polarization-transfer coefficient was measured to be consistent with zero. copyright 1998 The American Physical Society

  12. Spin-exchange and spin-destruction rates for the 3He-Na system

    International Nuclear Information System (INIS)

    Borel, P.I.; Soegaard, L.V.; Svendsen, W.E.; Andersen, N.

    2003-01-01

    Optically pumped Na is used as a spin-exchange partner to polarize 3 He. Polarizations around 20% have routinely been achieved in sealed spherical glass cells containing 3 He, N 2 , and a few droplets of Na. An optical technique has been developed to determine the Na- 3 He spin-exchange rate coefficient. By monitoring the Na spin relaxation ''in the dark,'' the average Na-Na spin-destruction cross section at 330 degree sign C is estimated to be around 5x10 -19 cm 2 . This value is 2-5 (15-30) times smaller than the previously reported values for the K-K (Rb-Rb) spin-relaxation cross section. In the temperature range 310-355 degree sign C the spin-exchange rate coefficient is found to be (6.1±0.6)x10 -20 cm 3 /s with no detectable temperature dependence. This value is in good agreement with a previous theoretical estimate reported by Walker and it is only slightly lower than the corresponding Rb- 3 He spin-exchange rate coefficient. The total Na- 3 He spin-destruction rate coefficient is, within errors, found to be the same as the Na- 3 He spin-exchange rate coefficient, thereby indicating that the maximum possible photon efficiency may approach unity for the Na- 3 He system. A technique, in which a charge-coupled device camera is used to take images of faint unquenched fluorescence light, has been utilized to allow for an instantaneous determination of the sodium number densities during the rate coefficient measurements

  13. Cryogenics free production of hyperpolarized 129Xe and 83Kr for biomedical MRI applications

    Science.gov (United States)

    Hughes-Riley, Theodore; Six, Joseph S.; Lilburn, David M. L.; Stupic, Karl F.; Dorkes, Alan C.; Shaw, Dominick E.; Pavlovskaya, Galina E.; Meersmann, Thomas

    2013-12-01

    As an alternative to cryogenic gas handling, hyperpolarized (hp) gas mixtures were extracted directly from the spin exchange optical pumping (SEOP) process through expansion followed by compression to ambient pressure for biomedical MRI applications. The omission of cryogenic gas separation generally requires the usage of high xenon or krypton concentrations at low SEOP gas pressures to generate hp 129Xe or hp 83Kr with sufficient MR signal intensity for imaging applications. Two different extraction schemes for the hp gasses were explored with focus on the preservation of the nuclear spin polarization. It was found that an extraction scheme based on an inflatable, pressure controlled balloon is sufficient for hp 129Xe handling, while 83Kr can efficiently be extracted through a single cycle piston pump. The extraction methods were tested for ex vivo MRI applications with excised rat lungs. Precise mixing of the hp gases with oxygen, which may be of interest for potential in vivo applications, was accomplished during the extraction process using a piston pump. The 83Kr bulk gas phase T1 relaxation in the mixtures containing more than approximately 1% O2 was found to be slower than that of 129Xe in corresponding mixtures. The experimental setup also facilitated 129Xe T1 relaxation measurements as a function of O2 concentration within excised lungs.

  14. Cryogenics free production of hyperpolarized 129Xe and 83Kr for biomedical MRI applications☆

    Science.gov (United States)

    Hughes-Riley, Theodore; Six, Joseph S.; Lilburn, David M.L.; Stupic, Karl F.; Dorkes, Alan C.; Shaw, Dominick E.; Pavlovskaya, Galina E.; Meersmann, Thomas

    2013-01-01

    As an alternative to cryogenic gas handling, hyperpolarized (hp) gas mixtures were extracted directly from the spin exchange optical pumping (SEOP) process through expansion followed by compression to ambient pressure for biomedical MRI applications. The omission of cryogenic gas separation generally requires the usage of high xenon or krypton concentrations at low SEOP gas pressures to generate hp 129Xe or hp 83Kr with sufficient MR signal intensity for imaging applications. Two different extraction schemes for the hp gasses were explored with focus on the preservation of the nuclear spin polarization. It was found that an extraction scheme based on an inflatable, pressure controlled balloon is sufficient for hp 129Xe handling, while 83Kr can efficiently be extracted through a single cycle piston pump. The extraction methods were tested for ex vivo MRI applications with excised rat lungs. Precise mixing of the hp gases with oxygen, which may be of interest for potential in vivo applications, was accomplished during the extraction process using a piston pump. The 83Kr bulk gas phase T1 relaxation in the mixtures containing more than approximately 1% O2 was found to be slower than that of 129Xe in corresponding mixtures. The experimental setup also facilitated 129Xe T1 relaxation measurements as a function of O2 concentration within excised lungs. PMID:24135800

  15. Specific features of kinetics of He3-He4 solid solution transformations at superlow temperatures

    International Nuclear Information System (INIS)

    Mikheev, V.A.; Majdanov, V.A.; Mikhin, N.P.

    1986-01-01

    The NMR data on the phase transition kinetics of 3 He- 4 He solid solutions at T=100 mK are considered. Studied are solid helium samples of a molecular volume of 20.55 cm 2 /mol with a 3 He content of 0.54 %. An unusually long phase transition time is found which is dependent on the prehistory of sample. The spin diffusion of 3 He in the transformated solution concentrated phase is found to be of a quasi-one-dimensional nature with the diffusion coefficient value typical of liquid

  16. Dimerization of 3He in 3He-4He mixture films

    International Nuclear Information System (INIS)

    Bashkin, E.

    1994-01-01

    3 He atoms dissolved in superfluid 4 He may form dimers ( 3 He) 2 in two-dimensional geometries. Dimer formation is studied in films of dilute 3 He- 4 He mixture. After designing a schematic 3 He- 3 He interaction potential, the dimer binding energy is calculated for various substrates. It is shown that 3 He impurity states localized near the substrate give rise to the highest magnitudes of the binding energy. (author). 32 refs., 6 figs.,; 1 tab

  17. T1 nuclear magnetic relaxation dispersion of hyperpolarized sodium and cesium hydrogencarbonate-13 C.

    Science.gov (United States)

    Martínez-Santiesteban, Francisco M; Dang, Thien Phuoc; Lim, Heeseung; Chen, Albert P; Scholl, Timothy J

    2017-09-01

    In vivo pH mapping in tissue using hyperpolarized hydrogencarbonate- 13 C has been proposed as a method to study tumor growth and treatment and other pathological conditions related to pH changes. The finite spin-lattice relaxation times (T 1 ) of hyperpolarized media are a significant limiting factor for in vivo imaging. Relaxation times can be measured at standard magnetic fields (1.5 T, 3.0 T etc.), but no such data are available at low fields, where T 1 values can be significantly shorter. This information is required to determine the potential loss of polarization as the agent is dispensed and transported from the polarizer to the MRI scanner. The purpose of this study is to measure T 1 dispersion from low to clinical magnetic fields (0.4 mT to 3.0 T) of different hyperpolarized hydrogencarbonate formulations previously proposed in the literature for in vivo pH measurements. 13 C-enriched cesium and sodium hydrogencarbonate preparations were hyperpolarized using dynamic nuclear polarization, and the T 1 values of different samples were measured at different magnetic field strengths using a fast field-cycling relaxometer and a 3.0 T clinical MRI system. The effects of deuterium oxide as a dissolution medium for sodium hydrogencarbonate were also analyzed. This study finds that the cesium formulation has slightly shorter T 1 values compared with the sodium preparation. However, the higher solubility of cesium hydrogencarbonate- 13 C means it can be polarized at greater concentration, using less trityl radical than sodium hydrogencarbonate- 13 C. This study also establishes that the preparation and handling of sodium hydrogencarbonate formulations in relation to cesium hydrogencarbonate is more difficult, due to the higher viscosity and lower achievable concentrations, and that deuterium oxide significantly increases the T 1 of sodium hydrogencarbonate solutions. Finally, this work also investigates the influence of pH on the spin-lattice relaxation of cesium

  18. EPR oxygen imaging and hyperpolarized 13C MRI of pyruvate metabolism as non-invasive biomarkers of tumor treatment response to a glycolysis inhibitor 3-bromopyruvate

    Science.gov (United States)

    Matsumoto, Shingo; Saito, Keita; Yasui, Hironobu; Morris, H. Douglas; Munasinghe, Jeeva P.; Lizak, Martin; Merkle, Hellmut; Ardenkjaer-Larsen, Jan Henrik; Choudhuri, Rajani; Devasahayam, Nallathamby; Subramanian, Sankaran; Koretsky, Alan P.; Mitchell, James B.; Krishna, Murali C.

    2012-01-01

    The hypoxic nature of tumors results in treatment resistance and poor prognosis. To spare limited oxygen for more crucial pathways, hypoxic cancerous cells suppress mitochondrial oxidative phosphorylation, and promote glycolysis for energy production. Thereby, inhibition of glycolysis has the potential to overcome treatment resistance of hypoxic tumors. Here, EPR imaging was used to evaluate oxygen dependent efficacy on hypoxia-sensitive drug. The small molecule 3-bromopyruvate (3-BP) blocks glycolysis pathway by inhibiting hypoxia inducible enzymes, and enhanced cytotoxicity of 3-BP under hypoxic conditions has been reported in vitro. However, the efficacy of 3-BP was substantially attenuated in hypoxic tumor regions (pO2 < 10 mmHg) in vivo using squamous cell carcinoma (SCCVII)-bearing mouse model. Metabolic MRI studies using hyperpolarized 13C-labeled pyruvate showed that monocarboxylate transporter-1 (MCT1) is the major transporter for pyruvate and the analog 3-BP in SCCVII tumor. The discrepant results between in vitro and in vivo data were attributed to biphasic oxygen dependent expression of MCT1 in vivo. Expression of MCT1 was enhanced in moderately hypoxic (8–15 mmHg) tumor regions, but down regulated in severely hypoxic (< 5 mmHg) tumor regions. These results emphasize the importance of non-invasive imaging biomarkers to confirm the action of hypoxia-activated drugs. PMID:22692861

  19. Brain Imaging Using Hyperpolarized 129Xe Magnetic Resonance Imaging.

    Science.gov (United States)

    Chahal, Simrun; Prete, Braedan R J; Wade, Alanna; Hane, Francis T; Albert, Mitchell S

    2018-01-01

    Hyperpolarized (HP) 129 Xe magnetic resonance imaging (MRI) is a novel iteration of traditional MRI that relies on detecting the spins of 1 H. Since 129 Xe is a gaseous signal source, it can be used for lung imaging. Additionally, 129 Xe dissolves in the blood stream and can therefore be detectable in the brain parenchyma and vasculature. In this work, we provide detailed information on the protocols that we have developed to image 129 Xe within the brains of both rodents and human subjects. © 2018 Elsevier Inc. All rights reserved.

  20. Bound states of 3He in 3He-4He mixture films

    International Nuclear Information System (INIS)

    Bashkin, E.; Pavloff, N.; Treiner, J.

    1995-01-01

    3 He atoms dissolved in superfluid 4 He may form dimers ( 3 He) 2 in two-dimensional (2D) geometries. We study dimer formation in films of dilute 3 He- 4 He mixture. After designing a schematic 3 He- 4 He interaction potential we calculate the dimer binding energy for various substrates. It is shown that 3 He impurity states localized near the substrate give rise to the largest magnitudes of the binding energies

  1. Spin polarized 3He: a ''new'' quantum fluid

    International Nuclear Information System (INIS)

    Lhuillier, C.; Laloe, F.

    1979-01-01

    The physical properties of a 3 He fluid are studied, in which all nuclear spins are parallel to each other (fully polarized 3 He). At low temperatures, significant differences can exist between this polarized fluid and normal 3 He. The origin of these differences is purely quantum mechanical and arises from the Pauli exclusion principle. At low densities, only the transport properties of the gas are modified. At higher densities. The equilibrium properties (virial coefficients) are also changed by the nuclear polarization. Changes of the liquid-vapour or liquid-solid equilibrium pressures, as well as modifications of the 3 He- 4 He mixture phase diagram are predicted. This article gives a preliminary theoretical study of these new effects. Experimental prospects are briefly discussed [fr

  2. Specific features of kinetics of He/sup 3/-He/sup 4/ solid solution transformations at superlow temperatures

    Energy Technology Data Exchange (ETDEWEB)

    Mikheev, V A; Majdanov, V A; Mikhin, N P

    1986-06-01

    The NMR data on the phase transition kinetics of /sup 3/He-/sup 4/He solid solutions at T=100 mK are considered. Studied are solid helium samples of a molecular volume of 20.55 cm/sup 2//mol with a /sup 3/He content of 0.54%. An unusually long phase transition time is found which is dependent on the prehistory of sample. The spin diffusion of /sup 3/He in the transformated solution concentrated phase is found to be of a quasi-one-dimensional nature with the diffusion coefficient value typical of liquid.

  3. MO-G-18C-03: Evaluation of Deformable Image Registration for Lung Motion Estimation Using Hyperpolarized Gas Tagging MRI

    International Nuclear Information System (INIS)

    Huang, Q; Zhang, Y; Liu, Y; Hu, L; Yin, F; Cai, J; Miller, W

    2014-01-01

    Purpose: Hyperpolarized gas (HP) tagging MRI is a novel imaging technique for direct measurement of lung motion during breathing. This study aims to quantitatively evaluate the accuracy of deformable image registration (DIR) in lung motion estimation using HP tagging MRI as references. Methods: Three healthy subjects were imaged using the HP MR tagging, as well as a high-resolution 3D proton MR sequence (TrueFISP) at the end-of-inhalation (EOI) and the end-of-exhalation (EOE). Ground truth of lung motion and corresponding displacement vector field (tDVF) was derived from HP tagging MRI by manually tracking the displacement of tagging grids between EOI and EOE. Seven different DIR methods were applied to the high-resolution TrueFISP MR images (EOI and EOE) to generate the DIR-based DVFs (dDVF). The DIR methods include Velocity (VEL), MIM, Mirada, multi-grid B-spline from Elastix (MGB) and 3 other algorithms from DIRART toolbox (Double Force Demons (DFD), Improved Lucas-Kanade (ILK), and Iterative Optical Flow (IOF)). All registrations were performed by independent experts. Target registration error (TRE) was calculated as tDVF – dDVF. Analysis was performed for the entire lungs, and separately for the upper and lower lungs. Results: Significant differences between tDVF and dDVF were observed. Besides the DFD and IOF algorithms, all other dDVFs showed similarity in deformation magnitude distribution but away from the ground truth. The average TRE for entire lung ranged 2.5−23.7mm (mean=8.8mm), depending on the DIR method and subject's breathing amplitude. Larger TRE (13.3–23.7mm) was found in subject with larger breathing amplitude of 45.6mm. TRE was greater in lower lung (2.5−33.9 mm, mean=12.4mm) than that in upper lung (2.5−11.9 mm, mean=5.8mm). Conclusion: Significant differences were observed in lung motion estimation between the HP gas tagging MRI method and the DIR methods, especially when lung motion is large. Large variation among different

  4. MO-G-18C-03: Evaluation of Deformable Image Registration for Lung Motion Estimation Using Hyperpolarized Gas Tagging MRI

    Energy Technology Data Exchange (ETDEWEB)

    Huang, Q; Zhang, Y [Duke University, Durham, NC (United States); Liu, Y [Duke University (United States); Hu, L; Yin, F; Cai, J [Duke University Medical Center, Durham, NC (United States); Miller, W [University of Virginia, Charlottesville, VA (United States)

    2014-06-15

    Purpose: Hyperpolarized gas (HP) tagging MRI is a novel imaging technique for direct measurement of lung motion during breathing. This study aims to quantitatively evaluate the accuracy of deformable image registration (DIR) in lung motion estimation using HP tagging MRI as references. Methods: Three healthy subjects were imaged using the HP MR tagging, as well as a high-resolution 3D proton MR sequence (TrueFISP) at the end-of-inhalation (EOI) and the end-of-exhalation (EOE). Ground truth of lung motion and corresponding displacement vector field (tDVF) was derived from HP tagging MRI by manually tracking the displacement of tagging grids between EOI and EOE. Seven different DIR methods were applied to the high-resolution TrueFISP MR images (EOI and EOE) to generate the DIR-based DVFs (dDVF). The DIR methods include Velocity (VEL), MIM, Mirada, multi-grid B-spline from Elastix (MGB) and 3 other algorithms from DIRART toolbox (Double Force Demons (DFD), Improved Lucas-Kanade (ILK), and Iterative Optical Flow (IOF)). All registrations were performed by independent experts. Target registration error (TRE) was calculated as tDVF – dDVF. Analysis was performed for the entire lungs, and separately for the upper and lower lungs. Results: Significant differences between tDVF and dDVF were observed. Besides the DFD and IOF algorithms, all other dDVFs showed similarity in deformation magnitude distribution but away from the ground truth. The average TRE for entire lung ranged 2.5−23.7mm (mean=8.8mm), depending on the DIR method and subject's breathing amplitude. Larger TRE (13.3–23.7mm) was found in subject with larger breathing amplitude of 45.6mm. TRE was greater in lower lung (2.5−33.9 mm, mean=12.4mm) than that in upper lung (2.5−11.9 mm, mean=5.8mm). Conclusion: Significant differences were observed in lung motion estimation between the HP gas tagging MRI method and the DIR methods, especially when lung motion is large. Large variation among different

  5. Polarized (3) He Spin Filters for Slow Neutron Physics.

    Science.gov (United States)

    Gentile, T R; Chen, W C; Jones, G L; Babcock, E; Walker, T G

    2005-01-01

    Polarized (3)He spin filters are needed for a variety of experiments with slow neutrons. Their demonstrated utility for highly accurate determination of neutron polarization are critical to the next generation of betadecay correlation coefficient measurements. In addition, they are broadband devices that can polarize large area and high divergence neutron beams with little gamma-ray background, and allow for an additional spin-flip for systematic tests. These attributes are relevant to all neutron sources, but are particularly well-matched to time of flight analysis at spallation sources. There are several issues in the practical use of (3)He spin filters for slow neutron physics. Besides the essential goal of maximizing the (3)He polarization, we also seek to decrease the constraints on cell lifetimes and magnetic field homogeneity. In addition, cells with highly uniform gas thickness are required to produce the spatially uniform neutron polarization needed for beta-decay correlation coefficient experiments. We are currently employing spin-exchange (SE) and metastability-exchange (ME) optical pumping to polarize (3)He, but will focus on SE. We will discuss the recent demonstration of 75 % (3)He polarization, temperature-dependent relaxation mechanism of unknown origin, cell development, spectrally narrowed lasers, and hybrid spin-exchange optical pumping.

  6. The Role of PDH Inhibition in the Development of Hypertrophy in the Hyperthyroid Rat Heart: A Combined MRI and Hyperpolarized MRS Study

    Science.gov (United States)

    Atherton, Helen J.; Dodd, Michael S.; Heather, Lisa C.; Schroeder, Marie A.; Griffin, Julian L.; Radda, George K.; Clarke, Kieran; Tyler, Damian J.

    2015-01-01

    Background Hyperthyroidism increases heart rate, contractility and cardiac output, as well as metabolic rate. It is also accompanied by alterations in the regulation of cardiac substrate utilisation. Specifically, hyperthyroidism increases the ex vivo activity of pyruvate dehydrogenase kinase (PDK), thereby inhibiting glucose oxidation via pyruvate dehydrogenase (PDH). Cardiac hypertrophy is another effect of hyperthyroidism, with an increase in the abundance of mitochondria. Although the hypertrophy is initially beneficial, it can eventually lead to heart failure. The aim of this study was to use hyperpolarized magnetic resonance spectroscopy (MRS) to investigate the rate and regulation of in vivo pyruvate dehydrogenase (PDH) flux in the hyperthyroid heart, and to establish whether modulation of flux through PDH would alter cardiac hypertrophy. Methods & Results Hyperthyroidism was induced in 18 male Wistar rats with 7 daily intraperitoneal injections of freshly prepared triiodothyronine (T3; 0.2 mg/kg/day). In vivo PDH flux, assessed using hyperpolarized MRS, was reduced by 59% in hyperthyroid animals (0.0022 ± 0.0002 s−1 vs 0.0055 ± 0.0005 s−1, P = 0.0003) and this reduction was completely reversed by both acute and chronic delivery of the PDK inhibitor, dichloroacetic acid (DCA). Hyperpolarized [2-13C]pyruvate was also used to evaluate Krebs cycle metabolism and demonstrated a unique marker of anaplerosis, the level of which was significantly increased in the hyperthyroid heart. Cine MRI showed that chronic DCA treatment significantly reduced the hypertrophy observed in hyperthyroid animals (100 ± 20 mg vs 200 ± 30 mg; P = 0.04) despite no change to the increase observed in cardiac output. Conclusions This work has demonstrated that inhibition of glucose oxidation in the hyperthyroid heart in vivo is PDK mediated. Relieving this inhibition can increase the metabolic flexibility of the hyperthyroid heart and reduce the level of hypertrophy that develops

  7. MRI

    DEFF Research Database (Denmark)

    Schroeter, Aileen; Rudin, Markus; Gianolio, Eliana

    2017-01-01

    This chapter discusses principles of nuclear magnetic resonance (NMR) and MRI followed by a survey on the major classes of MRI contrast agents (CA), their modes of action, and some of the most significative applications. The two more established classes of MRI-CA are represented by paramagnetic...... been attained that markedly increase the number and typology of systems with CEST properties. Currently much attention is also devoted to hyperpolarized molecules that display a sensitivity enhancement sufficient for their direct exploitation for the formation of the MR image. A real breakthrough...

  8. Large-space cluster model calculations for the 3He(3He,2p)4He and 3H(3H,2n)4He reactions

    International Nuclear Information System (INIS)

    Csoto, Attila; Langanke, Karlheinz

    1999-01-01

    The 3 He( 3 He, 2p) 4 He and 3 H( 3 H, 2n) 4 He reactions are studied in a microscopic cluster model. We search for resonances in the 3 He+ 3 He and 4 He + p + p channels using methods that treat the two- and three-body resonance asymptotics correctly. Our results show that the existence of a low-energy resonance or virtual state, which could influence the 7 Be and 8 B solar neutrino fluxes, is rather unlikely. Our calculated 3 He( 3 He, 2p) 4 He and 3 H( 3 H, 2n) 4 He cross sections are in a good general agreement with the experimental data

  9. Specific features of concentrated phase under decomposition of weak solid /sup 3/He-/sup 4/He solution

    Energy Technology Data Exchange (ETDEWEB)

    Mikheev, V A; Majdamov, V A; Kal' noj, S E; Omelaenko, N I

    1988-06-01

    The decomposition of solid /sup 3/He-/sup 4/He solutuions is studied on the samples 0.54% /sup 3/He(V=20.55 cm/sup 3//mole) and 0.60% /sup 4/He (V=24.04-24.93 cm/sup 3//mole) using pulse NMR method. At T=100 mK the decomposition of a weak solution proceeds more than for 30 h, the decomposition rate and temperature being dependent on the sample prehistory. In the concentrated phase of the decomposed weak solution the spin diffraction of /sup 3/He is of the quasi-one-dimensional character with the diffusion coefficient D /similar to/ 10/sup -5/ cm/sup 2//sec typical of liquid /sup 3/He and exceeding that bulk solid /sup 3/He by two orders of magnitude. The longitudinal relaxation time in the quasi-one-dimensional phase (/similar to/ 1 sec) is characteristic of the solid state and coinsides with data for bulk /sup 3/He. The temperature behaviour of magnetization in the quasi-one-dimensional phase is well described by the Curie law.

  10. Apparent diffusion coefficients of normal uterus in premenopausal women with 3 T MRI

    International Nuclear Information System (INIS)

    Kuang, F.; Chen, Z.; Zhong, Q.; Fu, L.; Ma, M.

    2013-01-01

    Aim: To investigate the apparent diffusion coefficient (ADC) values of the normal uterine cervical zonal structures (cervical epithelium, the junctional zone, and myometrium) during different phases of the menstrual cycle among premenopausal women in different age groups. Materials and methods: Seventy healthy women, who were divided into three age groups (group A, 24 women in their twenties; group B, 23 women in their thirties; group C, 23 women in their forties), underwent 3 T magnetic resonance imaging (MRI) with T2-weighted and diffusion-weighted imaging (DWI) during the mid-proliferative and the mid-secretory phases. Results: The ADC values of each cervical zonal structure were significantly different from one another (p 0.05). Conclusion: ADC values of normal cervical epithelium and the junctional zone change with different phases of the menstrual cycle, which should be taken into consideration when early cervical disease is detected, when monitoring treatment response, and differentiating early tumour recurrence

  11. Superfluid 3He dynamcs in 3He - 4He solutions

    International Nuclear Information System (INIS)

    Mejerovich, A.Eh.

    1984-01-01

    The dynamics of a 3 He- 4 He superfluid solution with two condensates ( 3 He and 4 He) is investigated. Despite the fact that the hydrodynamics of the system is a three-velocity one (two superfluid and one normal velocity), all the thermo- and hydrodynamic functions are determined by the value of only a single linear combination of the velocities. 0n the basis of an analogy between a moving solution and a BCS system with coupling with a non-zero momentum, the dependence of the thermodynamic quantities on the velocities and critical velocities can easily be calculated for both homogeneous and inhomogeneous phases of the solution. In a magnetic field the temperature oscillations (analogue of second sound for a superfluid solution) are accompanied by oscillations of the magnetic moment. The velocity and damping of the spin-temperature waves are determined. The orienting action of a current on the inhomogeneous phases of the solution is discussed. It is shown that the energy and size of the vortexes in a superfluid solution are, due to drag effects, oscillating functions of the effective mass of the 3 He quasirartictes (pressure). At a pressure of the order of 10 atm a first order transition should take place in the vortex line which is accompanied by an abrupt change of the circulations of superfluid velocity of 3 He for a fixed circulation of the 4 He velocity

  12. Collisional energy transfer in Na(4p--3d)--He,H2 collisions

    International Nuclear Information System (INIS)

    Kleiber, P.D.; Wong, T.H.; Bililign, S.

    1993-01-01

    We have investigated the direct collisional energy transfer process Na*(4p)+M→Na*(3d)+M, where M=He,H 2 under gas cell conditions. We have measured the temporal profiles of the Na(3d--3p) sensitized fluorescence as a function of quenching gas pressure and fit the profiles to a two-state rate equation model to obtain the quenching rate coefficients from the Na*(4p) state. The total energy transfer rate coefficient out of the 4p state for He is small [(0.5±0.2)x10 -10 cm 3 /s]. The total quenching rate coefficient out of the 4p state is much larger for H 2 [(3.9±0.5)x10 -10 cm 3 /s]. Evidence suggests that the energy transfer rate coefficient for the 4p--3d process is ∼2.0x10 -10 cm 3 /s with the remainder of the 4p quenching being predominantly reactive. We also compare the far-red wing absorption line shapes for the NaHe and NaH 2 systems

  13. Hyperpolarized Porous Silicon Nanoparticles: Potential Theragnostic Material for ²⁹Si Magnetic Resonance Imaging.

    Science.gov (United States)

    Seo, Hyeonglim; Choi, Ikjang; Whiting, Nicholas; Hu, Jingzhe; Luu, Quy Son; Pudakalakatti, Shivanand; McCowan, Caitlin; Kim, Yaewon; Zacharias, Niki; Lee, Seunghyun; Bhattacharya, Pratip; Lee, Youngbok

    2018-05-20

    Porous silicon nanoparticles have recently garnered attention as potentially-promising biomedical platforms for drug delivery and medical diagnostics. Here, we demonstrate porous silicon nanoparticles as contrast agents for ²⁹Si magnetic resonance imaging. Size-controlled porous silicon nanoparticles were synthesized by magnesiothermic reduction of silica nanoparticles and were surface activated for further functionalization. Particles were hyperpolarized via dynamic nuclear polarization to enhance their ²⁹Si MR signals; the particles demonstrated long ²⁹Si spin-lattice relaxation (T₁) times (~ 25 mins), which suggests potential applicability for medical imaging. Furthermore, ²⁹Si hyperpolarization levels were sufficient to allow ²⁹Si MRI in phantoms. These results underscore the potential of porous silicon nanoparticles that, when combined with hyperpolarized magnetic resonance imaging, can be a powerful theragnostic deep tissue imaging platform to interrogate various biomolecular processes in vivo. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  14. A validation of the 3H/3He method for determining groundwater recharge

    Science.gov (United States)

    Solomon, D. K.; Schiff, S. L.; Poreda, R. J.; Clarke, W. B.

    1993-09-01

    Tritium and He isotopes have been measured at a site where groundwater flow is nearly vertical for a travel time of 100 years and where recharge rates are spatially variable. Because the mid-1960s 3H peak (arising from aboveground testing of thermonuclear devices) is well-defined, the vertical groundwater velocity is known with unusual accuracy at this site. Utilizing 3H and its stable daughter 3He to determine groundwater ages, we compute a recharge rate of 0.16 m/yr, which agrees to within about 5% of the value based on the depth of the 3H peak (measured both in 1986 and 1991) and two-dimensional modeling in an area of high recharge. Zero 3H/3He age occurs at a depth that is approximately equal to the average depth of the annual low water table, even though the capillary fringe extends to land surface during most of the year at the study site. In an area of low recharge (0.05 m/yr) where the 3H peak (and hence the vertical velocity) is also well-defined, the 3H/3He results could not be used to compute recharge because samples were not collected sufficiently far above the 3H peak; however, modeling indicates that the 3H/3He age gradient near the water table is an accurate measure of vertical velocities in the low-recharge area. Because 3H and 3He have different diffusion coefficients, and because the amount of mechanical mixing is different in the area of high recharge than in the low-recharge area, we have separated the dispersive effects of mechanical mixing from molecular diffusion. We estimate a longitudinal dispersivity of 0.07 m and effective diffusion coefficients for 3H (3HHO) and 3He of 2.4×10-5 and 1.3×10-4 m2/day, respectively. Although the 3H/3He age gradient is an excellent indicator of vertical groundwater velocities above the mid-1960s 3H peak, dispersive mixing and diffusive loss of 3He perturb the age gradient near and below the 3H peak.

  15. Regional Ventilation Changes in the Lung: Treatment Response Mapping by Using Hyperpolarized Gas MR Imaging as a Quantitative Biomarker.

    Science.gov (United States)

    Horn, Felix C; Marshall, Helen; Collier, Guilhem J; Kay, Richard; Siddiqui, Salman; Brightling, Christopher E; Parra-Robles, Juan; Wild, Jim M

    2017-09-01

    Purpose To assess the magnitude of regional response to respiratory therapeutic agents in the lungs by using treatment response mapping (TRM) with hyperpolarized gas magnetic resonance (MR) imaging. TRM was used to quantify regional physiologic response in adults with asthma who underwent a bronchodilator challenge. Materials and Methods This study was approved by the national research ethics committee and was performed with informed consent. Imaging was performed in 20 adult patients with asthma by using hyperpolarized helium 3 ( 3 He) ventilation MR imaging. Two sets of baseline images were acquired before inhalation of a bronchodilating agent (salbutamol 400 μg), and one set was acquired after. All images were registered for voxelwise comparison. Regional treatment response, ΔR(r), was calculated as the difference in regional gas distribution (R[r] = ratio of inhaled gas to total volume of a voxel when normalized for lung inflation volume) before and after intervention. A voxelwise activation threshold from the variability of the baseline images was applied to ΔR(r) maps. The summed global treatment response map (ΔR net ) was then used as a global lung index for comparison with metrics of bronchodilator response measured by using spirometry and the global imaging metric percentage ventilated volume (%VV). Results ΔR net showed significant correlation (P treatment effect was detected with all metrics; however, ΔR net showed a lower intersubject coefficient of variation (64%) than all of the other tests (coefficient of variation, ≥99%). Conclusion TRM provides regional quantitative information on changes in inhaled gas ventilation in response to therapy. This method could be used as a sensitive regional outcome metric for novel respiratory interventions. © RSNA, 2017 Online supplemental material is available for this article.

  16. The sup(40,44,48)Ca(3He, 3He) and (3He, 4He) reactions at 50 MeV

    International Nuclear Information System (INIS)

    Griffiths, R.J.; Duggan, F.; Clarke, N.M.

    1981-01-01

    Measurements have been made of the ( 3 He, 3 He) and ( 3 He, 4 He) reactions on the isotopes of calcium 40 Ca, 44 Ca and 48 Ca at an energy of 50.4 MeV. The results have been analysed with conventional optical potentials and DWBA. The adequacy of the former and inadequacy of the latter for reactions with composite particles is discussed. (author)

  17. Combined He3 cryostats and He3-He4 dilution refrigerators

    International Nuclear Information System (INIS)

    Kovac, L.; Balla, J.

    1974-07-01

    A modular set of equipment was designed, which consists of a 4 He Dewar vessel with a very low evaporation rate, having a pumped 4 He bath in which either a 3 He cryostat or a dilution refrigerator within removable inserts can be placed. Any of them can be simply and rapidly connected to the versatile Dewar, auxiliary 4 He-, vacuum; and 3 He- 4 He systems. Two such sets have already been completed and can be used at temperatures from 1.5K to 0.05K for thermodynamic and neutron diffraction measurements. The performance of all inserts was stable and reliable, differences between the cryostats and runs were small - nearly all within the accuracy of temperature determination. The construction of a lot of parts is identical, allowing rapid manufacture. Assembling and repairs are simple, all parts are easily accessible. (K.A.)

  18. X-ray-induced thinning of 3He and 3He/4He mixture films

    International Nuclear Information System (INIS)

    Penanen, Konstantin; Fukuto, Masafumi; Silvera, Isaac F.; Pershan, Peter

    2000-01-01

    Films of isotopic mixtures of helium have been studied using x-ray specular reflectivity techniques. In contrast with superfluid 4 He films, x-ray exposure causes a reduction in the thickness of 4 He films above the superfluid transition as well as films of pure 3 He and 3 He/ 4 He mixtures. One proposed model that could account for this effect is a charging model, in which thinning is caused by electrostatic pressure of free charges that accumulate on the helium surface. Unfortunately, this model is not fully consistent with all of the experimental observations. A localized heating model, in which indirect heating of the film causes it to thin would explain the data if there were dissipative film flow in the 3 He/ 4 He mixtures at temperatures where the bulk is superfluid. We argue that various published experimental results suggest such an effect. In this model, film thinning data for dilute 3 He/ 4 He films indicates dissipation that is linear in 3 He content of the film over two orders of magnitude

  19. The relation between temperature and concentration gradients in superfluid sup 3 He- sup 4 He solutions

    CERN Document Server

    Zadorozhko, A A; Rudavskij, E Y; Chagovets, V K; Sheshin, G A

    2003-01-01

    The temperature and concentration gradients nabla T and nabla x in a superfluid sup 3 He- sup 4 He mixture with an initial concentration 9,8 % of sup 3 He are measured in a temperature range 70-500 mK. The gradients are produced by a steady thermal flow with heating from below. It is shown that the value of nabla x/nabla T observed in the experiment is in good agreement with the theoretical model derived from the temperature and concentration dependences of osmotic pressure. The experimental data permitted us to obtain a thermal diffusion ratio of the solution responsible for the thermal diffusion coefficient.

  20. Hyperpolarized krypton-83 as a contrast agent for magnetic resonance imaging.

    Science.gov (United States)

    Pavlovskaya, Galina E; Cleveland, Zackary I; Stupic, Karl F; Basaraba, Randall J; Meersmann, Thomas

    2005-12-20

    For the first time, magnetic resonance imaging (MRI) with hyperpolarized (hp) krypton-83 (83Kr) has become available. The relaxation of the nuclear spin of 83Kr atoms (I = 9/2) is driven by quadrupolar interactions during brief adsorption periods on surrounding material interfaces. Experiments in model systems reveal that the longitudinal relaxation of hp 83Kr gas strongly depends on the chemical composition of the materials. The relaxation-weighted contrast in hp 83Kr MRI allows for the distinction between hydrophobic and hydrophilic surfaces. The feasibility of hp 83Kr MRI of airways is tested in canine lung tissue by using krypton gas with natural abundance isotopic distribution. Additionally, the influence of magnetic field strength and the presence of a breathable concentration of molecular oxygen on longitudinal relaxation are investigated.

  1. Low-field MRI can be more sensitive than high-field MRI

    Science.gov (United States)

    Coffey, Aaron M.; Truong, Milton L.; Chekmenev, Eduard Y.

    2013-12-01

    MRI signal-to-noise ratio (SNR) is the key factor for image quality. Conventionally, SNR is proportional to nuclear spin polarization, which scales linearly with magnetic field strength. Yet ever-stronger magnets present numerous technical and financial limitations. Low-field MRI can mitigate these constraints with equivalent SNR from non-equilibrium ‘hyperpolarization' schemes, which increase polarization by orders of magnitude independently of the magnetic field. Here, theory and experimental validation demonstrate that combination of field independent polarization (e.g. hyperpolarization) with frequency optimized MRI detection coils (i.e. multi-turn coils using the maximum allowed conductor length) results in low-field MRI sensitivity approaching and even rivaling that of high-field MRI. Four read-out frequencies were tested using samples with identical numbers of 1H and 13C spins. Experimental SNRs at 0.0475 T were ∼40% of those obtained at 4.7 T. Conservatively, theoretical SNRs at 0.0475 T 1.13-fold higher than those at 4.7 T were possible despite an ∼100-fold lower detection frequency, indicating feasibility of high-sensitivity MRI without technically challenging, expensive high-field magnets. The data at 4.7 T and 0.0475 T was obtained from different spectrometers with different RF probes. The SNR comparison between the two field strengths accounted for many differences in parameters such as system noise figures and variations in the probe detection coils including Q factors and coil diameters.

  2. Irreversible Catalyst Activation Enables Hyperpolarization and Water Solubility for NMR Signal Amplification by Reversible Exchange

    Science.gov (United States)

    2016-09-12

    G. R.; Duckett, S. B.; Spiess , H. W.; Schreiber, L. M.; Münnemann, K. Continuous Proton Hyperpolarization Via SABRE and Hollow Fibre Membranes. Proc...M.; Kindervater, P.; Raich, H.-P.; Bargon, J.; Spiess , H. W.; Muennemann, K. Continuous H-1 and C-13 Signal Enhancement in NMR Spectroscopy and MRI

  3. Influence of the intermediate bcc phase on the evolution of superfluid inclusions in hcp matrix 3He-4He

    International Nuclear Information System (INIS)

    Birchenko, A.P.; Mikhin, N.P.; Neoneta, A.S.; Rudavskij, Eh.Ya.; Fisun, Ya.Yu.

    2016-01-01

    The evolution of liquid inclusions which are formed in the hcp matrix by rapid cooling of the 3 He- 4 He solution containing 1.05% 3 He was studied by pulse NMR. The diffusion coefficient of 3 He in the liquid was measured by two-pulses spin-echo method during evolution of the inclusions. Measurements were carried out at 1.67 K which corresponds to the bcc phase existence in the phase diagram, as well as at 1.38 K, where the bcc phase is absent. It is found that in the process of the evolution, in both cases the size of the liquid inclusions is less than diffusion length and so the diffusion is restricted. The measured restricted dif-fusion coefficient allowed to find the characteristic size of the inclusions. In the first case, during the evolution of liquid inclusions, dendrites of intermediate bcc phase is forming and the inclusions are separating into a lot of smaller droplets. Due to the rapid growth of the bcc dendrites, the droplet size decreases rapidly, and the process comes to disappearance of bcc phase and an amorphous state appearance. The results obtained by measuring the diffusion coefficient, correlated with the behavior of the spin-lattice relaxation time in such a system. In the second case at a lower temperature bcc phase is not formed, and the size of the liquid inclusions decreases very slow until the completion of their solidification.

  4. In vivo single-shot (13)C spectroscopic imaging of hyperpolarized metabolites by spatiotemporal encoding

    DEFF Research Database (Denmark)

    Schmidt, Rita; Laustsen, Christoffer; Dumez, Jean-Nicolas

    2014-01-01

    are necessary. Several approaches have been customized for hyperpolarized (13)C MRI, including CSI with a center-out k-space encoding, EPSI, and spectrally selective pulses in combination with spiral EPI acquisitions. Recent studies have described the potential of single-shot alternatives based...... temporal) data sets were obtained at 7T from a murine lymphoma tumor model....

  5. Dynamically Decoupled 13C Spins in Hyperpolarized Nanodiamond

    Science.gov (United States)

    Rej, Ewa; Gaebel, Torsten; Boele, Thomas; Waddington, David; Reilly, David

    The spin-spin relaxation time, T2, which determines how long a quantum state remains coherent, is an important factor for many applications ranging from MRI to quantum computing. A common technique used in quantum information technology to extend the T2, involves averaging out certain noise spectra via dynamical decoupling sequences. Depending on the nature of the noise in the system, specific sequences, such as CPMG, UDD or KDD, can be tailored to optimize T2. Here we combine hyperpolarization techniques and dynamical decoupling sequences to extend the T2 of 13C nuclear spins in nanodiamond by three orders of magnitude.

  6. Calculations of long-range three-body interactions for He(n0λS )-He(n0λS )-He(n0'λL )

    Science.gov (United States)

    Yan, Pei-Gen; Tang, Li-Yan; Yan, Zong-Chao; Babb, James F.

    2018-04-01

    We theoretically investigate long-range interactions between an excited L -state He atom and two identical S -state He atoms for the cases of the three atoms all in spin-singlet states or all in spin-triplet states, denoted by He(n0λS )-He(n0λS )-He(n0'λL ), with n0 and n0' principal quantum numbers, λ =1 or 3 the spin multiplicity, and L the orbital angular momentum of a He atom. Using degenerate perturbation theory for the energies up to second-order, we evaluate the coefficients C3 of the first-order dipolar interactions and the coefficients C6 and C8 of the second-order additive and nonadditive interactions. Both the dipolar and dispersion interaction coefficients, for these three-body degenerate systems, show dependences on the geometrical configurations of the three atoms. The nonadditive interactions start to appear in second-order. To demonstrate the results and for applications, the obtained coefficients Cn are evaluated with highly accurate variationally generated nonrelativistic wave functions in Hylleraas coordinates for He(1 1S ) -He(1 1S ) -He(2 1S ) , He(1 1S ) -He(1 1S ) -He(2 1P ) , He(2 1S ) -He(2 1S ) -He(2 1P ) , and He(2 3S ) -He(2 3S ) -He(2 3P ) . The calculations are given for three like nuclei for the cases of hypothetical infinite mass He nuclei, and of real finite mass 4He or 3He nuclei. The special cases of the three atoms in equilateral triangle configurations are explored in detail, and for the cases in which one of the atoms is in a P state, we also present results for the atoms in an isosceles right triangle configuration or in an equally spaced collinear configuration. The results can be applied to construct potential energy surfaces for three helium atom systems.

  7. Thermal transport properties in dilute 3He-4He mixtures near the superfluid transition

    International Nuclear Information System (INIS)

    Tuttle, J.G.

    1991-01-01

    The author describes measurements of various transport properties of dilute liquid 3 He- 4 He mixtures in two different sample cells. One cell was designed to measure the temperature drop ΔT across a fluid layer due to an applied heat flux Q, and the other allowed measurement of both ΔT and ΔX, the molar concentration drop. He studied the anomalous boundary resistance, ΔR b , in superfluid 4 He near T λ for Q between 4 and 100μW/cm 2 . He presents results for both the weakly divergent and the heat dependent, more strongly divergent contributions. He compares his data with those of Duncan and Ahlers and with theoretical predictions by Frank and Dohm. He also presents similar R b data for a mixture with X = 2.5 x 10 -6 . He determined the relaxation time τ for transients observed during thermal conductivity κ eff and thermal diffusion k T * measurements in superfluid mixtures between 1.7K and T λ with X ranging from 10 -6 to 5 x 10 -2 . He compares these results, taken with a fluid layer thickness h = 1.81 mm, with theoretical predictions and with earlier data for h = 1.47 mm. He shows the mass diffusion coefficient D computed both from τ and from κ eff data for 0.001 λ , and he compares the results of these two different determinations. In addition, he presents the 3 He-roton scattering cross section calculated using D results. In the normal phase he measured the thermal diffusion ratio k T and the thermal conductivity κ for 0.009 ≤ X ≤ 0.05 near T λ , and he compares these results with predictions by Dohm and Folk

  8. Polarisation and compression of 3He for Magnetic Resonance Imaging purposes

    International Nuclear Information System (INIS)

    Geurts, D. G.; Brand, J. F. J. van den; Bulten, H. J.; Poolman, H. R.; Ferro-Luzzi, M.; Nicolay, K.

    1998-01-01

    Magnetic Resonance Imaging is often used in medical science as a diagnostic tool for the human body. Conventional MRI uses the NMR signal from the protons of water molecules in tissue to image the interior of the patient's body. However, for certain areas such as the lungs and airways, the usage of a highly polarised gas yields better results. We are currently constructing an apparatus that uses polarised 3 He gas to produce detailed images of those signal-deficient moyeties. We also plan to study possible uptake of polarised 3 He gas by the circulatory system to image other organs

  9. Specific heat of amorphous 3He films and confined liquid 3He

    International Nuclear Information System (INIS)

    Golov, A.; Pobell, F.

    1995-01-01

    We have measured the heat capacities of 3 He films and liquid 3 He in porous Vycor glass at 10 to 600 mK. With increasing the film thickness front 1 to 3 atomic layers , the specific heat evolves gradually from that typical to solid to that of liquid 3 He. At about 2 atomic layers, however, its low-temperature part is nearly temperature-independent; we interpret this as a result of gradual freezing of spins in an amorphous solid 3 He film with decreasing the temperature. The contribution of liquid 3 He in the center of the Vycor pores can be described as the specific heat of bulk liquid 3 He at corresponding pressures in the range 0 to 28 bar. The thickness of amorphous solid on the pore walls increases with external pressure roughly linearly. Preplating the walls with 4 He allows to determine the positions of 3 He atoms contributing to the surface specific heat at 10 to 50 mK. In addition, the contribution from the specific heat of 3 He- 4 He mixing at 100 to 600 mK is discussed as a function of pressure and amount of 4 He

  10. Improved results for the 2H(d, n)3He transverse vector polarization-transfer coefficient Kyy'(0o) at low energies

    International Nuclear Information System (INIS)

    Roper, C.D.; Dunham, J.D.; Clegg, T.B.; Mendez, A.J.; Tornow, W.; Walter, R.L.

    2010-01-01

    Measurements of the 2 H(d, n) 3 He transverse vector polarization-transfer coefficient K y y' at 0 o . are reported for 29 outgoing neutron energies between 3.94 and 8.47 MeV. Our new results determine K y y' (0 o ) more accurately than previous data, especially for neutron energies below 5 MeV. Low-energy data for this reaction are important both as a high-intensity source of highly polarized neutrons for nuclear physics studies with polarized neutron beams, and as a test of the emerging theoretical descriptions of the four-body system, where recently substantial progress has been made. (author)

  11. MR imaging of the stomach and relaxation measurement with intraluminal hyperpolarized 129Xenon gas

    International Nuclear Information System (INIS)

    Yanagawa, Yasuhiro; Kimura, Atsuomi; Fujiwara, Hideaki; Kinoshita, Yoshimasa; Hattori, Mineyuki; Hiraga, Takashi; Iida, Hidehiro

    2001-01-01

    Using laser optical pumping, the nuclear spin polarization of noble gases can be strongly enhanced. The purpose of this study was to make a simple apparatus that can provide hyperpolarized 129 Xe gas, which can then be used in an attempt to obtain magnetic resonance imaging (MRI). We would also like to study the relaxation behavior of hyperpolarized 129 Xe gas through the measurement of the relaxation time. First, we demonstrated that hyperpolarized 129 Xe gas can be applied to magnetic resonance imaging of the stomach, by using a rat as a model. This was performed under a 4.7 T magnet field using the following imaging parameters for the hyperpolarized 129 Xe gas: TR=50 ms, TE=15 ms, FOV=10 x 10 cm 2 , matrix size 64 x 64, THK=2.54 cm. By using these parameters, we were able to obtain a hyperpolarized image of the stomach in rats for the first time. Next, we measured the relaxation times of the hyperpolarized 129 Xe gas enclosed in cavities such as the stomach of rats as well as in phantoms created by glass and gelatin bulbs. The cavity size dependency of the relaxation time was analyzed on the basis of the kinetic theory of gases. This analysis showed a linear relationship between the relaxation rate (1/T 1 ) and a square inverse of the cavity diameter (1/d 2 ). From this relationship, the wall effect on the 129 Xe relaxation can be estimated in the novel parameter t 1 , wall . This shows drastic dependency on the material of the wall, suggesting a potential use of the relaxation experiment as a diagnostic tool for organ surfaces in the future. (author)

  12. Binary and ternary recombination of D3+ ions with electrons in He-D2 plasma

    International Nuclear Information System (INIS)

    Glosik, J.; Korolov, I.; Plasil, R.; Kotrik, T.; Dohnal, P.; Novotny, O.; Varju, J.; Roucka, S.; Greene, Chris H.; Kokoouline, V.

    2009-01-01

    An experimental study is reported about the recombination of D 3 + ions with electrons in a low-temperature plasma (200-300 K) consisting of He with a small admixture of D 2 . At several temperatures, the pressure dependence of the apparent binary recombination rate coefficient (α eff ) was measured over a broad range of helium pressures (200-2000 Pa). The binary and ternary recombination rate coefficients were obtained from measured pressure dependences of α eff . The binary recombination rate coefficient obtained α bin (300 K)=(2.7±0.9)x10 -8 cm 3 s -1 is in agreement with recent theory. The ternary recombination rate coefficient obtained is K He (300 K)=(1.8±0.6)x10 -25 cm 6 s -1 . In analogy with the recently described process of helium-assisted ternary recombination of H 3 + ions, it is suggested that the ternary helium-assisted recombination of D 3 + ions proceeds through the formation of a neutral long-lived highly excited Rydberg molecule D 3 followed by a collision with a He atom.

  13. Cold collisions of SH- with He: Potential energy surface and rate coefficients

    Science.gov (United States)

    Bop, C. T.; Trabelsi, T.; Hammami, K.; Mogren Al Mogren, M.; Lique, F.; Hochlaf, M.

    2017-09-01

    Collisional energy transfer under cold conditions is of great importance from the fundamental and applicative point of view. Here, we investigate low temperature collisions of the SH- anion with He. We have generated a three-dimensional potential energy surface (PES) for the SH-(X1Σ+)-He(1S) van der Waals complex. The ab initio multi-dimensional interaction PES was computed using the explicitly correlated coupled cluster approach with simple, double, and perturbative triple excitation in conjunction with the augmented-correlation consistent-polarized valence triple zeta Gaussian basis set. The PES presents two minima located at linear geometries. Then, the PES was averaged over the ground vibrational wave function of the SH- molecule and the resulting two-dimensional PES was incorporated into exact quantum mechanical close coupling calculations to study the collisional excitation of SH- by He. We have computed inelastic cross sections among the 11 first rotational levels of SH- for energies up to 2500 cm-1. (De-)excitation rate coefficients were deduced for temperatures ranging from 1 to 300 K by thermally averaging the cross sections. We also performed calculations using the new PES for a fixed internuclear SH- distance. Both sets of results were found to be in reasonable agreement despite differences existing at low temperatures confirming that accurate predictions require the consideration of all internal degrees of freedom in the case of molecular hydrides. The rate coefficients presented here may be useful in interpreting future experimental work on the SH- negative ion colliding with He as those recently done for the OH--He collisional system as well as for possible astrophysical applications in case SH- would be detected in the interstellar medium.

  14. Attractive well of He--He from 3He--4He differential elastic scattering measurements

    International Nuclear Information System (INIS)

    Burgmans, A.L.J.; Farrar, J.M.; Lee, Y.T.

    1976-01-01

    The elastic differential cross section for 3 He-- 4 He was measured at a relative collision energy of 0.799x10 -14 erg, approximately five times the well depth. The data are fitted to a multiparameter potential form with epsilon/k=10.57 degreeK and r/subm/=2.97 A. Comparisons with recent experimental and theoretical helium potentials are made. No evidence for a significant isotope effect in the 3 He-- 4 He and 4 He-- 4 He interactomic potentials is found in this work

  15. Superfluidity of a dilute 3He-4He solution

    International Nuclear Information System (INIS)

    Soda, Toshio

    1993-01-01

    The interaction between two 3 He atoms is calculated by taking into account the backflow effect of 3 He by the 4 He in the 3 He- 4 He mixture. The effect contributes solely to the P wave part of the interaction. The repulsive S wave part of the contact interaction contributes to the exchange interaction between the 3 He atoms, while the direct one phonon exchange interaction contributes both to the S and P wave attractive interactions. The overall contribution to the attractive interaction is dominated by the P wave part and the superfluidity in the P wave is more predominant than in the S wave for the 5 % dilute 3 He- 4 He solution, and vice versa for the 1.3 % solution. (author)

  16. 3He flow in dilute 3He-4He mixtures at temperatures between 10 and 150 mK

    International Nuclear Information System (INIS)

    Castelijns, C.A.M.; Kuerten, J.G.M.; de Waele, A.T.A.M.; Gijsman, H.M.

    1985-01-01

    The mutual friction between 3 He and 4 He II below 150 mK has been studied. Empirical relations for the adiabatic and the nonadiabatic flow properties of 3 He moving through 4 He have been determined using a dilution refrigerator with a single mixing chamber. The validity of the relations is verified by osmotic-pressure measurements and by measuring the properties of a double-mixing-chamber system. It is shown that superleak shunts have a strong effect on the flow characteristics. From the nonadiabatic flow properties an expression is derived for the mutual-friction-force density between 3 He and 4 He II. This has a strong resemblance to the Gorter-Mellink mutual-friction-force density between the normal and the superfluid components in pure 4 He II. It is speculated that the 3 He flow in our systems generates a 4 He vortex tangle, which leads to the observed mutual friction between 3 He and 4 He and also to a strong clamping of the 4 He to the walls

  17. Structure and dynamics of molecular complex He2*(a3Σu+) in condensed phases of helium

    International Nuclear Information System (INIS)

    Kafanov, S.G.; Parshin, A.Ya.; Tadoshchenko, I.A.

    2000-01-01

    The absorption spectra of the helium triplet metastable molecules in the a 3 Σ u + states in the liquid 4 He and 3 He by various pressures and in the 3 He dense gas are studied. The analysis of the spectrum, corresponding to the a 3 Σ u + → c 3 Σ g + transition, proves the conclusion on the availability of a microscopic bubble, surrounding the molecule in the liquid helium. Simple approximation of the wave function of the molecule valent electron is proposed and the bubble parameters under various experimental conditions are determined. The coefficient conditions are determined. The coefficient of the molecular recombination in the liquid 3 He and 4 He by different pressures and in the 3 He cold gas is experimentally determined. The obtained results agree well with the mutual recombination theory. It is shown, that molecular polarization in the helium condensed phases under the magnetic field effect does not lead to their mutual recombination [ru

  18. 4He-impurity effects on normal liquid 3He at low temperatures I - preliminary ideas and calculations

    International Nuclear Information System (INIS)

    Ghassib, H.B.; Chatterjee, S.

    1982-02-01

    The effects of 4 He impurities on the low-temperature properties of normal liquid 3 He are explored. It is argued that these effects should manifest themselves in, among other properties, the liquid structure factor at very low temperatures and momentum transfers, the acoustic impedance near the transition region from the zero- to the first-sound regime, the propagation of sound, the phase diagram, and the magnetic properties - including the magnetokinetic coefficients of the spin-polarized system. Several experiments are suggested to detect these macroscopic manifestations. (author)

  19. [MRI methods for pulmonary ventilation and perfusion imaging].

    Science.gov (United States)

    Sommer, G; Bauman, G

    2016-02-01

    Separate assessment of respiratory mechanics, gas exchange and pulmonary circulation is essential for the diagnosis and therapy of pulmonary diseases. Due to the global character of the information obtained clinical lung function tests are often not sufficiently specific in the differential diagnosis or have a limited sensitivity in the detection of early pathological changes. The standard procedures of pulmonary imaging are computed tomography (CT) for depiction of the morphology as well as perfusion/ventilation scintigraphy and single photon emission computed tomography (SPECT) for functional assessment. Magnetic resonance imaging (MRI) with hyperpolarized gases, O2-enhanced MRI, MRI with fluorinated gases and Fourier decomposition MRI (FD-MRI) are available for assessment of pulmonary ventilation. For assessment of pulmonary perfusion dynamic contrast-enhanced MRI (DCE-MRI), arterial spin labeling (ASL) and FD-MRI can be used. Imaging provides a more precise insight into the pathophysiology of pulmonary function on a regional level. The advantages of MRI are a lack of ionizing radiation, which allows a protective acquisition of dynamic data as well as the high number of available contrasts and therefore accessible lung function parameters. Sufficient clinical data exist only for certain applications of DCE-MRI. For the other techniques, only feasibility studies and case series of different sizes are available. The clinical applicability of hyperpolarized gases is limited for technical reasons. The clinical application of the techniques described, except for DCE-MRI, should be restricted to scientific studies.

  20. MRI methods for pulmonary ventilation and perfusion imaging

    International Nuclear Information System (INIS)

    Sommer, G.; Bauman, G.

    2016-01-01

    Separate assessment of respiratory mechanics, gas exchange and pulmonary circulation is essential for the diagnosis and therapy of pulmonary diseases. Due to the global character of the information obtained clinical lung function tests are often not sufficiently specific in the differential diagnosis or have a limited sensitivity in the detection of early pathological changes. The standard procedures of pulmonary imaging are computed tomography (CT) for depiction of the morphology as well as perfusion/ventilation scintigraphy and single photon emission computed tomography (SPECT) for functional assessment. Magnetic resonance imaging (MRI) with hyperpolarized gases, O 2 -enhanced MRI, MRI with fluorinated gases and Fourier decomposition MRI (FD-MRI) are available for assessment of pulmonary ventilation. For assessment of pulmonary perfusion dynamic contrast-enhanced MRI (DCE-MRI), arterial spin labeling (ASL) and FD-MRI can be used. Imaging provides a more precise insight into the pathophysiology of pulmonary function on a regional level. The advantages of MRI are a lack of ionizing radiation, which allows a protective acquisition of dynamic data as well as the high number of available contrasts and therefore accessible lung function parameters. Sufficient clinical data exist only for certain applications of DCE-MRI. For the other techniques, only feasibility studies and case series of different sizes are available. The clinical applicability of hyperpolarized gases is limited for technical reasons. The clinical application of the techniques described, except for DCE-MRI, should be restricted to scientific studies. (orig.) [de

  1. The cross section of 3He(3He,2p)4He measured at solar energies

    International Nuclear Information System (INIS)

    Junker, M.; Arpesella, C.; Bellotti, E.; Broggini, C.; Corvisiero, P.; D'Alessandro, A.; Fiorentini, G.; Fubini, A.; Gervino, G.; Greife, U.; Gustavino, C.; Lambert, J.; Prati, P.; Rodney, W.S.; Rolfs, C.; Trautvetter, H.P.; Zavatarelli, S.

    1999-01-01

    We report on the status of the 3 He( 3 He,2p) 4 He experiment at the underground accelerator facility LUNA (Gran Sasso). The lowest projectile energies for the measured cross section correspond already to energies below the center of the solar Gamow peak (E 0 =22 keV). The data provide no evidence for the existence of a hypothetical resonance in the energy range investigated. Although no extrapolation is needed anymore (except for energies at the low-energy tail of the Gamow peak), the data must be corrected for the effects of electron screening, clearly observed the first time for the 3 He( 3 He,2p) 4 He reaction. The effects are however larger than expected and not understood, leading presently to the largest uncertainty on the quoted S(0) value for bare nuclides (= 5.40 MeVb)

  2. Fast dynamic ventilation MRI of hyperpolarized 129 Xe using spiral imaging.

    Science.gov (United States)

    Doganay, Ozkan; Matin, Tahreema N; Mcintyre, Anthony; Burns, Brian; Schulte, Rolf F; Gleeson, Fergus V; Bulte, Daniel

    2018-05-01

    To develop and optimize a rapid dynamic hyperpolarized 129 Xe ventilation (DXeV) MRI protocol and investigate the feasibility of capturing pulmonary signal-time curves in human lungs. Spiral k-space trajectories were designed with the number of interleaves N int  = 1, 2, 4, and 8 corresponding to voxel sizes of 8 mm, 5 mm, 4 mm, and 2.5 mm, respectively, for field of view = 15 cm. DXeV images were acquired from a gas-flow phantom to investigate the ability of N int  = 1, 2, 4, and 8 to capture signal-time curves. A finite element model was constructed to investigate gas-flow dynamics corroborating the experimental signal-time curves. DXeV images were also carried out in six subjects (three healthy and three chronic obstructive pulmonary disease subjects). DXeV images and numerical modelling of signal-time curves permitted the quantification of temporal and spatial resolutions for different numbers of spiral interleaves. The two-interleaved spiral (N int  = 2) was found to be the most time-efficient to obtain DXeV images and signal-time curves of whole lungs with a temporal resolution of 624 ms for 13 slices. Signal-time curves were well matched in three healthy volunteers. The Spearman's correlations of chronic obstructive pulmonary disease subjects were statistically different from three healthy subjects (P spiral demonstrates the successful acquisition of DXeV images and signal-time curves in healthy subjects and chronic obstructive pulmonary disease patients. Magn Reson Med 79:2597-2606, 2018. © 2017 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine. This is an open access article under the terms of the Creative Commons Attribution License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited. © 2017 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc

  3. Experimental measurements of 3He and 4He mobility in olivine and clinopyroxene at magmatic temperatures

    Science.gov (United States)

    Trull, T. W.; Kurz, M. D.

    1993-03-01

    In-vacuo heating of 0.5 -0.7 mm olivine and clinopyroxene grains separated from Hawaiian ultramafic xenoliths leads to complete He loss within hours to days for temperatures of 700-1400°C. Diffusivities calculated from the observed release rates assuming spherical grains and initially homogeneous He distributions define Arrhenius relations with activation energies of 420 ± 20 and 290 ± 40 Kj/mol and log 10D0 of +5.1 ± .7 and +2.1 ± 1.2 cm 2/s in olivine and pyroxene, respectively. Values at 1350°C are 5.3 × 10 -9 cm 2/s in olivine and 10 times faster in pyroxene (4.7 × 10 -8 cm 2/s). These values include small corrections for grain size variations and, in the case of olivine, about 15% prior diffusive He loss. However, an important factor that has not been considered in previous studies of this type, is that the xenolith He resides predominantly within CO 2 rich fluid inclusions. Theoretical description of He loss in such a case demonstrates that the diffusivities calculated using the standard approach actually represent the product of the true volume diffusivity ( D) and the helium solubility, as represented by the distribution coefficient KDv (defined by C crystal/C fluid). Although He solubility in crystals is not well determined, estimates based on the CO 2 concentrations in these samples suggest that it is very low ( KDv of 3 × 10 -4 for pyroxene and 6 × 10 -6 for olivine; which also implies low crystal-melt distribution coefficients of .05 and .001). The resultant corrected diffusion rates are significantly faster than those obtained by the standard approach (~ 10 -4 cm 2/s at 1350°C and are thus higher than basaltic melt values). The most reasonable interpretation of this result is that He release is enhanced by internal grain fractures, including the planar healed cracks along which most fluid inclusions are arrayed. This treatment illustrates the difficulties involved in extrapolating laboratory He release measurements to nature, in particular

  4. Kinetic energy of He atoms in liquid 4He-3He mixtures

    International Nuclear Information System (INIS)

    Senesi, R.; Andreani, C.; Fielding, A.L.; Mayers, J.; Stirling, W.G.

    2003-01-01

    Deep inelastic neutron scattering measurements on liquid 3 He- 4 He mixtures in the normal phase have been performed on the VESUVIO spectrometer at the ISIS pulsed neutron source at exchanged wave vectors of about q≅120.0 A -1 . The neutron Compton profiles J(y) of the mixtures were measured along the T=1.96 K isotherm for 3 He concentrations, x, ranging from 0.1 to 1.0 at saturated vapor pressures. Values of kinetic energies of 3 He and 4 He atoms as a function of x, (x), were extracted from the second moment of J(y). The present determinations of (x) confirm previous experimental findings for both isotopes and, in the case of 3 He, a substantial disagreement with theory is found. In particular (x) for the 3 He atoms is found to be independent of concentration yielding a value 3 (x=0.1)≅12 K, much lower than the value suggested by the most recent theoretical estimates of approximately 19 K

  5. 3T MRI induced post-traumatic stress disorder: a case report

    Directory of Open Access Journals (Sweden)

    Lakhan Shaheen E

    2012-10-01

    Full Text Available Abstract Introduction MRI is considered a safe and well tolerated imaging technique with risks largely limited to heating and/or displacement of implanted ferromagnetic metal in the patient’s body, worsening anxiety, triggering claustrophobia, and gadolinium induced nephrogenic systemic fibrosis. Case presentation We present a case of a 26 year old Asian American man with no significant past medical or psychiatric history and two months of left T4 radicular pain. During 3T-MRI of the whole spine, the patient experienced acute agitation, fear, anxiety, tachypnea, tachycardia with palpitations, and dizziness. He felt intense surface heat over segments of his body and very loud noises. He perceived impending serious bodily harm by the scanner. The scan was aborted at the lumbar spine, and cervical and thoracic spine was unremarkable. The patient’s pain resolved in the weeks following with over the counter analgesics, however, he developed increased arousal, re-experiencing the event, persistent avoidance, and significant psychosocial impairment consistent with DSM-IV-TR criteria for post-traumatic stress disorder (PTSD. Conclusion This is the first reported case of MRI induced PTSD. Theoretically, the high-magnetic field of the 3T scanner may have contributed to the development of symptoms.

  6. Study of charge symmetry in 4He by simultaneous 4He(e,e'p)3H and 4He(e,e'n)3He measurements

    International Nuclear Information System (INIS)

    Spahn, M.; Kihm, T.; Knopfle, K.T.; Friedrich, J.; Voegler, N.; Schmitt, C.; Walther, V.H.; Unkelbach, M.; Hofmann, H.M.

    1989-01-01

    We have measured the ( 3 H+p) and ( 3 He+n) breakup of 4 He by 4 He(e,e'c) coincidence experiments at low momentum transfer (q∼0.39 fm -1 ) in the excitation energy region 22≤E x ≤36 MeV. Both channels were studied simultaneously by detecting the charged fragments c=p, 3 H, and 3 He in the same detector system. The measured 4 He(e,e'p) 3 H and 4 He(e,e'n) 3 He angular correlations as well as the deduced total 4 He(e,e'p) 3 H and 4 He(e,e'n) 3 He cross sections are reproduced by microscopic model calculations with a charge-symmetric nuclear Hamiltonian

  7. Feasibility, tolerability and safety of pediatric hyperpolarized {sup 129}Xe magnetic resonance imaging in healthy volunteers and children with cystic fibrosis

    Energy Technology Data Exchange (ETDEWEB)

    Walkup, Laura L.; Watters, Erin; Ruppert, Kai [Cincinnati Children' s Hospital Medical Center, Center for Pulmonary Imaging Research, Division of Pulmonary Medicine and Department of Radiology, Cincinnati, OH (United States); Thomen, Robert P.; Woods, Jason C. [Cincinnati Children' s Hospital Medical Center, Center for Pulmonary Imaging Research, Division of Pulmonary Medicine and Department of Radiology, Cincinnati, OH (United States); Washington University in St. Louis, Department of Physics, St. Louis, MO (United States); Akinyi, Teckla G.; Cleveland, Zackary I. [Cincinnati Children' s Hospital Medical Center, Center for Pulmonary Imaging Research, Division of Pulmonary Medicine and Department of Radiology, Cincinnati, OH (United States); University of Cincinnati, Biomedical Engineering Program, Cincinnati, OH (United States); Clancy, John P. [Cincinnati Children' s Hospital Medical Center, Division of Pulmonary Medicine, Cincinnati, OH (United States)

    2016-11-15

    Hyperpolarized {sup 129}Xe is a promising contrast agent for MRI of pediatric lung function, but its safety and tolerability in children have not been rigorously assessed. To assess the feasibility, safety and tolerability of hyperpolarized {sup 129}Xe gas as an inhaled contrast agent for pediatric pulmonary MRI in healthy control subjects and in children with cystic fibrosis. Seventeen healthy control subjects (ages 6-15 years, 11 boys) and 11 children with cystic fibrosis (ages 8-16 years, 4 boys) underwent {sup 129}Xe MRI, receiving up to three doses of {sup 129}Xe gas prepared by either a commercially available or a homebuilt {sup 129}Xe polarizer. Subject heart rate and SpO{sub 2} were monitored for 2 min post inhalation and compared to resting baseline values. Adverse events were reported via follow-up phone call at days 1 and 30 (range ±7 days) post-MRI. All children tolerated multiple doses of {sup 129}Xe, and no children withdrew from the study. Relative to baseline, most children who received a full dose of gas for imaging (10 of 12 controls and 8 of 11 children with cystic fibrosis) experienced a nadir in SpO{sub 2} (mean -6.0 ± standard deviation 7.2%, P≤0.001); however within 2 min post inhalation SpO{sub 2} values showed no significant difference from baseline (P=0.11). There was a slight elevation in heart rate (mean +6.6 ± 13.9 beats per minute [bpm], P=0.021), which returned from baseline within 2 min post inhalation (P=0.35). Brief side effects related to the anesthetic properties of xenon were mild and quickly resolved without intervention. No serious or severe adverse events were observed; in total, four minor adverse events (14.3%) were reported following {sup 129}Xe MRI, but all were deemed unrelated to the study. The feasibility, safety and tolerability of {sup 129}Xe MRI has been assessed in a small group of children as young as 6 years. SpO{sub 2} changes were consistent with the expected physiological effects of a short anoxic breath

  8. Rotational spectrum of the NH3He van der Waals complex

    Directory of Open Access Journals (Sweden)

    Surin L.

    2017-01-01

    Full Text Available The interaction between ammonia and helium has attracted considerable interest over many years, partly because of the observation of interstellar ammonia. The rate coefficients of NH3He scattering are an important ingredient for numerical modeling of astrochemical environments. Another, though quite different application in which the NH3He interaction can play an important role is the doping of helium clusters with NH3 molecules to perform high-resolution spectroscopy. Such experiments are directed on the detection of non-classical response of molecular rotation in helium clusters addressing fundamental questions related to the microscopic nature of superfluidity. High-resolution spectroscopy on the NH3He complex is an important tool for increasing our understanding of intermolecular forces between NH3 and He.

  9. Integrated B1+ Mapping for Hyperpolarized 13C MRI in a Clinical Setup using Multi-Channel Receive Arrays

    DEFF Research Database (Denmark)

    Hansen, Rie Beck; Shin, Peter J.; Gordon, Jeremy W.

    inhomogeneous transmit coils, and because kinetic modeling based on incorrect flip angles can lead to incorrect rate constant estimations. This study demonstrates the feasibility of integrated B1+ mapping for large volume thermal and hyperpolarized phantoms in a clinical setup using a clamshell transmit coil...... and a 16-channel receive array, and a 3D stack-of-spirals sequence. Phase-sensitive coil-combination was achieved using ESPIRiT....

  10. CH3CO + O2 + M (M = He, N2) Reaction Rate Coefficient Measurements and Implications for the OH Radical Product Yield.

    Science.gov (United States)

    Papadimitriou, Vassileios C; Karafas, Emmanuel S; Gierczak, Tomasz; Burkholder, James B

    2015-07-16

    The gas-phase CH3CO + O2 reaction is known to proceed via a chemical activation mechanism leading to the formation of OH and CH3C(O)OO radicals via bimolecular and termolecular reactive channels, respectively. In this work, rate coefficients, k, for the CH3CO + O2 reaction were measured over a range of temperature (241-373 K) and pressure (0.009-600 Torr) with He and N2 as the bath gas and used to characterize the bi- and ter-molecular reaction channels. Three independent experimental methods (pulsed laser photolysis-laser-induced fluorescence (PLP-LIF), pulsed laser photolysis-cavity ring-down spectroscopy (PLP-CRDS), and a very low-pressure reactor (VLPR)) were used to characterize k(T,M). PLP-LIF was the primary method used to measure k(T,M) in the high-pressure regime under pseudo-first-order conditions. CH3CO was produced by PLP, and LIF was used to monitor the OH radical bimolecular channel reaction product. CRDS, a complementary high-pressure method, measured k(295 K,M) over the pressure range 25-600 Torr (He) by monitoring the temporal CH3CO radical absorption following its production via PLP in the presence of excess O2. The VLPR technique was used in a relative rate mode to measure k(296 K,M) in the low-pressure regime (9-32 mTorr) with CH3CO + Cl2 used as the reference reaction. A kinetic mechanism analysis of the combined kinetic data set yielded a zero pressure limit rate coefficient, kint(T), of (6.4 ± 4) × 10(-14) exp((820 ± 150)/T) cm(3) molecule(-1) s(-1) (with kint(296 K) measured to be (9.94 ± 1.3) × 10(-13) cm(3) molecule(-1) s(-1)), k0(T) = (7.39 ± 0.3) × 10(-30) (T/300)(-2.2±0.3) cm(6) molecule(-2) s(-1), and k∞(T) = (4.88 ± 0.05) × 10(-12) (T/300)(-0.85±0.07) cm(3) molecule(-1) s(-1) with Fc = 0.8 and M = N2. A He/N2 collision efficiency ratio of 0.60 ± 0.05 was determined. The phenomenological kinetic results were used to define the pressure and temperature dependence of the OH radical yield in the CH3CO + O2 reaction. The

  11. Renal MR angiography and perfusion in the pig using hyperpolarized water

    DEFF Research Database (Denmark)

    Lipsø, Hans Kasper Wigh; Hansen, Esben Søvsø Szocska; Tougaard, Rasmus Stilling

    2016-01-01

    at 3 Tesla (T). Approximately 15 mL of hyperpolar-ized water was injected in the renal artery by hand over 4–5 s.Results: A liquid state polarization of 5.3 6 0.9% of 3.8 M pro-tons in 15 mL of deuterium oxide was achieved with a T1of24 6 1 s. This allowed injection through an arterial catheterinto...

  12. Hyperpolarized Nanodiamond Surfaces.

    Science.gov (United States)

    Rej, Ewa; Gaebel, Torsten; Waddington, David E J; Reilly, David J

    2017-01-11

    The widespread use of nanodiamond as a biomedical platform for drug-delivery, imaging, and subcellular tracking applications stems from its nontoxicity and unique quantum mechanical properties. Here, we extend this functionality to the domain of magnetic resonance, by demonstrating that the intrinsic electron spins on the nanodiamond surface can be used to hyperpolarize adsorbed liquid compounds at low fields and room temperature. By combining relaxation measurements with hyperpolarization, spins on the surface of the nanodiamond can be distinguished from those in the bulk liquid. These results are likely of use in signaling the controlled release of pharmaceutical payloads.

  13. Specific-heat measurements on dilute 3He-4He mixtures

    International Nuclear Information System (INIS)

    Zeeuw, H.C.M. van der.

    1985-01-01

    The author measured the specific heat of dilute 3 He- 4 He mixtures in the concentration range from X = 1 x 10 -3 to X = 3 x 10 -3 and in the temperature range from 100 mK to 600 mK. This has been done by means of a thermal relaxation method. This method provides some interesting features and is applied, to our knowledge, for the first time to dilute 3 He- 4 He mixtures. To reach the required temperature range for our experiments a 4 He circulating 3 He- 4 He dilution refrigerator has been constructed. The results confirm the deviation of the 3 He contribution to the specific heat from the ideal Fermi gas behaviour. (Auth.)

  14. A microscopic calculation of the fourth-rank shear viscosity tensors of superfluid phases of 3He

    International Nuclear Information System (INIS)

    Shahzamanian, M.A.

    1988-01-01

    The fourth-rank shear viscosity tensor of the superfluid phases of 3 He is obtained by using the Kubo formula approach. The viscosity coefficients of 3 He-A, and shear viscosity of 3 He-B are calculated with two different relaxation time approximations. The results for the temperature- and energy-independent relaxation times are in agreement with existing experimental data. (author)

  15. Hyperpolarized NMR Probes for Biological Assays

    Directory of Open Access Journals (Sweden)

    Sebastian Meier

    2014-01-01

    Full Text Available During the last decade, the development of nuclear spin polarization enhanced (hyperpolarized molecular probes has opened up new opportunities for studying the inner workings of living cells in real time. The hyperpolarized probes are produced ex situ, introduced into biological systems and detected with high sensitivity and contrast against background signals using high resolution NMR spectroscopy. A variety of natural, derivatized and designed hyperpolarized probes has emerged for diverse biological studies including assays of intracellular reaction progression, pathway kinetics, probe uptake and export, pH, redox state, reactive oxygen species, ion concentrations, drug efficacy or oncogenic signaling. These probes are readily used directly under natural conditions in biofluids and are often directly developed and optimized for cellular assays, thus leaving little doubt about their specificity and utility under biologically relevant conditions. Hyperpolarized molecular probes for biological NMR spectroscopy enable the unbiased detection of complex processes by virtue of the high spectral resolution, structural specificity and quantifiability of NMR signals. Here, we provide a survey of strategies used for the selection, design and use of hyperpolarized NMR probes in biological assays, and describe current limitations and developments.

  16. Improved Results for the H-2(d, n)(3) He Transverse Vector Polarization- Transfer Coefficient K-y(y)' (0 degrees) at Low Energies

    International Nuclear Information System (INIS)

    Roper, C.D.; Clegg, T.; Dunham, J.D.; Mendez, Anthony J. II; Tornow, W.; Walter, R.L.

    2010-01-01

    Measurements of the H-2(d, n)(3) He transverse vector polarization-transfer coefficient K-y(y)' at 0 degrees. are reported for 29 outgoing neutron energies between 3.94 and 8.47MeV. Our new results determine K-y(y)' (0 degrees) more accurately than previous data, especially for neutron energies below 5MeV. Low-energy data for this reaction are important both as a high-intensity source of highly polarized neutrons for nuclear physics studies with polarized neutron beams, and as a test of the emerging theoretical descriptions of the four-body system, where recently substantial progress has been made.

  17. Feasibility, tolerability and safety of pediatric hyperpolarized "1"2"9Xe magnetic resonance imaging in healthy volunteers and children with cystic fibrosis

    International Nuclear Information System (INIS)

    Walkup, Laura L.; Watters, Erin; Ruppert, Kai; Thomen, Robert P.; Woods, Jason C.; Akinyi, Teckla G.; Cleveland, Zackary I.; Clancy, John P.

    2016-01-01

    Hyperpolarized "1"2"9Xe is a promising contrast agent for MRI of pediatric lung function, but its safety and tolerability in children have not been rigorously assessed. To assess the feasibility, safety and tolerability of hyperpolarized "1"2"9Xe gas as an inhaled contrast agent for pediatric pulmonary MRI in healthy control subjects and in children with cystic fibrosis. Seventeen healthy control subjects (ages 6-15 years, 11 boys) and 11 children with cystic fibrosis (ages 8-16 years, 4 boys) underwent "1"2"9Xe MRI, receiving up to three doses of "1"2"9Xe gas prepared by either a commercially available or a homebuilt "1"2"9Xe polarizer. Subject heart rate and SpO_2 were monitored for 2 min post inhalation and compared to resting baseline values. Adverse events were reported via follow-up phone call at days 1 and 30 (range ±7 days) post-MRI. All children tolerated multiple doses of "1"2"9Xe, and no children withdrew from the study. Relative to baseline, most children who received a full dose of gas for imaging (10 of 12 controls and 8 of 11 children with cystic fibrosis) experienced a nadir in SpO_2 (mean -6.0 ± standard deviation 7.2%, P≤0.001); however within 2 min post inhalation SpO_2 values showed no significant difference from baseline (P=0.11). There was a slight elevation in heart rate (mean +6.6 ± 13.9 beats per minute [bpm], P=0.021), which returned from baseline within 2 min post inhalation (P=0.35). Brief side effects related to the anesthetic properties of xenon were mild and quickly resolved without intervention. No serious or severe adverse events were observed; in total, four minor adverse events (14.3%) were reported following "1"2"9Xe MRI, but all were deemed unrelated to the study. The feasibility, safety and tolerability of "1"2"9Xe MRI has been assessed in a small group of children as young as 6 years. SpO_2 changes were consistent with the expected physiological effects of a short anoxic breath-hold, and other mild side effects were

  18. Correlation of apparent diffusion coefficient ratio on 3.0 T MRI with prostate cancer Gleason score.

    Science.gov (United States)

    Jyoti, Rajeev; Jain, Tarun Pankaj; Haxhimolla, Hodo; Liddell, Heath; Barrett, Sean Edward

    2018-01-01

    The purpose was to investigate the usefulness of ADC ratio on Diffusion MRI to discriminate between benign and malignant lesions of Prostate. Images of patients who underwent in-gantry MRI guided prostate lesion biopsy were retrospectively analyzed. Prostate Cancers with 20% or more Gleason score (GS) pattern 3 + 3 = 6 in each core or any volume of higher Gleason score pattern were included. ADC ratio was calculated by two reviewers for each lesion. The ADC ratio was calculated for each lesion by dividing the lowest ADC value in a lesion and highest ADC value in normal prostate in peripheral zone (PZ). ADC ratio values were compared with the biopsy result. Data was analysed using independent samples T-test, Spearman correlation, intra-class correlation coefficient (ICC) and Receiver operating characteristic (ROC) curve. 45 lesions in 33 patients were analyzed. 12 lesions were in transitional zone (TZ) and 33 in perpheral zone PZ. All lesions demonstrated an ADC ratio of 0.45 or lower. GS demonstrated a negative correlation with both the ADC value and ADC ratio . However, ADC ratio (p correlation compared to ADC value alone (p = 0.014). There was no significant statistical difference between GS 3 + 4 and GS 4 + 3 mean ADC tumour value (p = 0.167). However when using ADC ratio , there was a significant difference (p = 0.032). ROC curve analysis demonstrated an area under the curve of 0.83 using ADC ratio and 0.76 when using ADC tumour value when discriminating Gleason 6 from Gleason ≥7 tumours. Inter-observer reliability in the calculation of ADC ratios was excellent, with ICC of 0.964. ADC ratio is a reliable and reproducible tool in quantification of diffusion restriction for clinically significant prostate cancer foci.

  19. Galactic evolution of D and 3He including stellar production of 3He

    International Nuclear Information System (INIS)

    Dearborn, D.S.; Steigman, G.; Tosi, M.

    1996-01-01

    New stellar models which track the production and destruction of 3 He (and D) have been evolved for a range of stellar masses (0.65≤M/M circle-dot ≤100), metallicities (0.01≤Z/Z circle-dot ≤1), and initial (main-sequence) 3 He mass fractions (10 -5 ≤X 3,MS ≤10 -3 ). Armed with the 3 He yields from these stellar models we have followed the evolution of D and 3 He using a variety of chemical evolution models with and without infall of primordial or processed material. Production of new 3 He by the lower mass stars overwhelms any reasonable primordial contributions and leads to predicted abundances in the presolar nebula and/or the present interstellar medium in excess of the observationally inferred values. This result, which obtains even for zero primordial D and 3 He, and was anticipated by Rood, Steigman, ampersand Tinsley is insensitive to the choice of chemical evolution model; it is driven by the large 3 He yields from low-mass stars. In an attempt to ameliorate this problem we have considered a number of nonstandard models in which the yields from low-mass stars have been modified. Although several of these nonstandard models may be consistent with the 3 He data, they may be inconsistent with observations of 12 C/ 13 C, 18 O, and, most seriously the super- 3 He rich planetary nebulae. Even using the most extreme of these nonstandard models we obtain a generous upper bound to pregalactic 3 He:X 3P ≤3.2x10 -5 which, nonetheless, leads to a stringent lower bound to the universal density of nucleons. copyright 1996 The American Astronomical Society

  20. Hyperpolarized nanodiamond with long spin-relaxation times

    Science.gov (United States)

    Rej, Ewa; Gaebel, Torsten; Boele, Thomas; Waddington, David E. J.; Reilly, David J.

    2015-10-01

    The use of hyperpolarized agents in magnetic resonance, such as 13C-labelled compounds, enables powerful new imaging and detection modalities that stem from a 10,000-fold boost in signal. A major challenge for the future of the hyperpolarization technique is the inherently short spin-relaxation times, typically nanodiamond can be hyperpolarized at cryogenic and room temperature without the use of free radicals, and, owing to their solid-state environment, exhibit relaxation times exceeding 1 h. Combined with the already established applications of nanodiamonds in the life sciences as inexpensive fluorescent markers and non-cytotoxic substrates for gene and drug delivery, these results extend the theranostic capabilities of nanoscale diamonds into the domain of hyperpolarized magnetic resonance.

  1. Hyperpolarized 13C-MRSI and PET (hyperPET) in an Osteomyelitis Pig Model

    DEFF Research Database (Denmark)

    Rahbek, Sofie; Gutte, Henrik; Johannesen, Helle H

    2017-01-01

    -PET for imaging of infection. METHODS: Three pigs were inoculated with S. aureusbacteria in the right tibia and saline in the left tibial bone. FDG-PET, 1H-MRI and 13C-MRSI was performed using a clinical whole-body PET/MR system (Siemens Biograph mMR, Erlangen, Germany). Hyperpolarized13C-pyruvate was prepared...... was observed outside the right (infected bone) on 1H-MRI and confirmed by histopathology. In the abscess the 13C-lactate to 13C-pyruvate ratio was increased as compared to the inflammatory region of the control leg. 18F-FDG uptake showed no clear trend when comparing abscess versus inflammation, but showed...

  2. Energy dependence of the 3He(3He,π+)6Li reaction

    International Nuclear Information System (INIS)

    Le Bornec, Y.; Hibou, F.; Bimbot, L.; Hennino, T.; Jourdain, J.C.; Reide, F.; Tatischeff, B.; Willis, N.; Aslanides, E.; Bergdolt, G.; Fassnacht, P.; Racca, C.; Boudard, A.; Bruge, G.; Lugol, J.C.

    1983-01-01

    The 3 He( 3 He, π + ) 6 Li reaction has been studied as a function of energy using the 3 He beam at SATURNE. Cross sections for the 6 Li ground state (1 + ) and 2.18 MeV (3 + ) levels have been obtained at 350, 420, 500 and 600 MeV incident energies at angles THETAsub(π)(lab)=15 0 and 40 0 . These results are compared with two theoretical predictions. (orig.)

  3. Recombination of H+3 ions in the afterglow of a He-Ar-H2 plasma

    International Nuclear Information System (INIS)

    Glosik, J; Korolov, I; Plasil, R; Novotny, O; Kotrik, T; Hlavenka, P; Varju, J; Mikhailov, I A; Kokoouline, V; Greene, Chris H

    2008-01-01

    Recombination of H + 3 with electrons is studied in a low-temperature plasma containing He, H 2 and Ar at different He and H 2 densities. The effective plasma recombination rate is driven by binary, H + 3 + e - , and ternary, H + 3 + e - + He, processes with the rate coefficients 7.5 x 10 -8 cm 3 s -1 and 2.8 x 10 -25 cm 6 s -1 respectively at 260 K. We suggest that the ternary recombination involves formation of neutral highly excited Rydberg H 3 followed by an l-changing collision with He. The difference between recombination of para- and ortho-H + 3 is discussed. (fast track communication)

  4. The search for high-energy deuterons in the 3He +3He reaction

    International Nuclear Information System (INIS)

    Pigeon, R.; Slobodrian, R.J.

    1979-01-01

    High-energy deuterons have been detected from the 3 He + 3 He reaction with a system sensitive to cross-sections of 0.6 nb sr -1 . Several tests have permitted to evaluate the small contribution of spurious events. The deuterons are kenematically consistent with the reaction 3 He + 3 He→ 2 H + 4 He + e + +ν, but the measured cross-section at 20deg laboratory is too high for a weak-interaction process; (1.3 +- 0.2) nb sr -1 . It might be due to an interaction of intermediate strength causing the decay of pp pairs ( 3 He) into deuterons. Other alternatives and the implications concerning fusion processes and the production of neutrinos in the sun are discussed in the text

  5. Multi-slice Fractional Ventilation Imaging in Large Animals with Hyperpolarized Gas MRI

    Science.gov (United States)

    Emami, Kiarash; Xu, Yinan; Hamedani, Hooman; Xin, Yi; Profka, Harrilla; Rajaei, Jennia; Kadlecek, Stephen; Ishii, Masaru; Rizi, Rahim R.

    2012-01-01

    Noninvasive assessment of regional lung ventilation is of critical importance in quantifying the severity of disease and evaluating response to therapy in many pulmonary diseases. This work presents for the first time the implementation of a hyperpolarized (HP) gas MRI technique for measuring whole-lung regional fractional ventilation (r) in Yorkshire pigs (n = 5) through the use of a gas mixing and delivery device in supine position. The proposed technique utilizes a series of back-to-back HP gas breaths with images acquired during short end-inspiratory breath-holds. In order to decouple the RF pulse decay effect from ventilatory signal build-up in the airways, regional distribution of flip angle (α) was estimated in the imaged slices by acquiring a series of back-to-back images with no inter-scan time delay during a breath-hold at the tail-end of the ventilation sequence. Analysis was performed to assess the multi-slice ventilation model sensitivity to noise, oxygen and number of flip angle images. The optimal α value was determined based on minimizing the error in r estimation; αopt = 5–6° for the set of acquisition parameters in pigs. The mean r values for the group of pigs were 0.27±0.09, 0.35±0.06, 0.40±0.04 for ventral, middle and dorsal slices, respectively, (excluding conductive airways r > 0.9). A positive gravitational (ventral-dorsal) ventilation gradient effect was present in all animals. The trachea and major conductive airways showed a uniform near-unity r value, with progressively smaller values corresponding to smaller diameter airways, and ultimately leading to lung parenchyma. Results demonstrate the feasibility of measurements of fractional ventilation in large species, and provides a platform to address technical challenges associated with long breathing time scales through the optimization of acquisition parameters in species with a pulmonary physiology very similar to that of human beings. PMID:22290603

  6. Quenching of 4He(21S,21P) and 3He(21S,21P) states by collisions with Ne(1S0) atoms

    International Nuclear Information System (INIS)

    Blagoev, K.B.; Dimova, E.; Petrov, G.M.

    2004-01-01

    The cross sections and rate constants for quenching 4 He(2 1 S), 4 He(2 1 P), 3 He(2 1 S) and 3 He(2 1 P) states by collisions with ground state Ne atoms are measured by a time-resolved method in a He-Ne electron beam excited plasma at low pressure. These rate constants at T g =600 K are: k 4 He(2 1 S) =(1.6±0.2)x10 -10 , k 4 He(2 1 P) =(3.4±2.5)x10 -10 , k 3 He(2 1 S) =(1.6±0.2)x10 -10 and k 3 He(2 1 P) =(5.7±1.2)x10 -10 cm 3 s -1 . The cross sections derived from the rate constant are σ 4 He(2 1 S) =(8.4±0.8)x10 -16 , σ 4 He(2 1 P) =(1.8±1.3)x10 -15 , σ 3 He(2 1 S) =(7.1±0.9)x10 -16 and σ 3 He(2 1 P) =(2.6±0.5)x10 -15 cm 2 , respectively. The diffusion coefficient of 3 He(2 1 S) in 3 He is estimated to be D 3 He(2 1 S)- 3 He =1.9D 4 He(2 1 S)- 4 He , based on comparison with 4 He. A time-dependent collisional radiative model for an e-beam sustained He-Ne plasma is developed and the predicted line intensity of NeI λ=6328 A line is compared with the experimental data. The influence of different processes involved in population and depopulation dynamics of He(2 1 S) state are evaluated

  7. Binary and ternary recombination of D3+ ions with electrons in He-D2 plasma

    Science.gov (United States)

    Glosík, J.; Korolov, I.; Plašil, R.; Kotrík, T.; Dohnal, P.; Novotný, O.; Varju, J.; Roučka, Š.; Greene, Chris H.; Kokoouline, V.

    2009-10-01

    An experimental study is reported about the recombination of D3+ ions with electrons in a low-temperature plasma (200-300 K) consisting of He with a small admixture of D2 . At several temperatures, the pressure dependence of the apparent binary recombination rate coefficient (αeff) was measured over a broad range of helium pressures (200-2000 Pa). The binary and ternary recombination rate coefficients were obtained from measured pressure dependences of αeff . The binary recombination rate coefficient obtained αbin(300K)=(2.7±0.9)×10-8cm3s-1 is in agreement with recent theory. The ternary recombination rate coefficient obtained is KHe(300K)=(1.8±0.6)×10-25cm6s-1 . In analogy with the recently described process of helium-assisted ternary recombination of H3+ ions, it is suggested that the ternary helium-assisted recombination of D3+ ions proceeds through the formation of a neutral long-lived highly excited Rydberg molecule D3 followed by a collision with a He atom.

  8. Simultaneous PET/MRI with 13C magnetic resonance spectroscopic imaging (hyperPET): phantom-based evaluation of PET quantification

    DEFF Research Database (Denmark)

    Hansen, Adam E.; Andersen, Flemming L.; Henriksen, Sarah T.

    2016-01-01

    Background: Integrated PET/MRI with hyperpolarized 13C magnetic resonance spectroscopic imaging (13C-MRSI) offers simultaneous, dual-modality metabolic imaging. A prerequisite for the use of simultaneous imaging is the absence of interference between the two modalities. This has been documented...... for a clinical whole-body system using simultaneous 1 H-MRI and PET but never for 13C-MRSI and PET. Here, the feasibility of simultaneous PET and 13C-MRSI as well as hyperpolarized 13C-MRSI in an integrated whole-body PET/MRI hybrid scanner is evaluated using phantom experiments. Methods: Combined PET and 13C......-MRSI phantoms including a NEMA [18F]-FDG phantom, 13C-acetate and 13C-urea sources, and hyperpolarized 13C-pyruvate were imaged repeatedly with PET and/or 13C-MRSI. Measurements evaluated for interference effects included PET activity values in the largest sphere and a background region; total number of PET...

  9. Echo-planar MR imaging of dissolved hyperpolarized 129Xe. Potential for M angiography

    International Nuclear Information System (INIS)

    Maansson, S.

    2002-01-01

    Purpose: The feasibility of hyperpolarized 129 Xe for fast MR angiography (MRA) was evaluated using the echo-planar imaging (EPI) technique. Material and Methods: Hyperpolarized Xe gas was dissolved in ethanol; a carrier agent with high solubility for Xe (Ostwald solubility coefficient 2.5) and long relaxation times. The dissolved Xe was injected as a bolus into a flow phantom where the mean flow velocity was 15 cm/s. Ultrafast EPI images with 44 ms scan time were acquired of the flowing bolus and the signal-to-noise ratios (SNR) were measured. Results: The relaxation times of hyperpolarized Xe in ethanol were measured to T1=160±11 s and T2 ≅ 20 s. The resulting images of the flowing liquid were of reasonable quality and had an SNR of about 70. Conclusion: Based on the SNR of the obtained Xe EPI images; it was estimated that rapid in vivo MRA with 129 Xe may be feasible; provided that an efficient; biologically acceptable carrier for Xe can be found and polarization levels of more than 25% can be achieved in isotopically enriched 129 Xe

  10. Contactless friction and the {sup 3}He-{sup 4}He dimer. Studies with the atomic-beam spin-echo spectrometer; Kontaktlose Reibung und das {sup 3}He-{sup 4}He-Dimer. Untersuchungen mit dem Atomstrahlspinechospektrometer

    Energy Technology Data Exchange (ETDEWEB)

    Janke, Matthias

    2016-04-20

    In this thesis the time of flight resolved atomic beam spin echo method (SEToF) is applied to a {sup 3}He-beam for the first time and studied systematically. This method is shown to be superior to the usual atomic beam spin echo technique. With SEToF it is possible to almost completely remove unpolarized background and to reach a beam polarisation close to 100%. The SEToF technique is shown to be crucial for the first experimental proof of the existence of the {sup 3}He-{sup 4}He dimer. This dimer is the weakest bound van-der-Waals-molecule known to date. Furthermore, a drag force between an atom and a dielectric surface is detected originating from the fluctuating dipole moment of the atom. Not only the measured friction coefficients match their theoretical predictions perfectly, but our data also shows the correct temperature dependence. A great many technological renewals and improvements were installed in the apparatus during this thesis work. They have become necessary or sensible due to the relocation of the physics institute. A few of them are documented and motivated in this thesis.

  11. Efficient 3He/4He separation in a nanoporous graphenylene membrane.

    Science.gov (United States)

    Qu, Yuanyuan; Li, Feng; Zhao, Mingwen

    2017-08-16

    Helium-3 is a precious noble gas, which is essential in many advanced technologies such as cryogenics, isotope labeling and nuclear weapons. The current imbalance of 3 He demand and supply shortage leads to the search for an efficient membrane with high performance for 3 He separation. In this study, based on first-principles calculations, we demonstrated that highly efficient 3 He harvesting can be achieved in a nanoporous graphenylene membrane with industrially-acceptable selectivity and permeance. The quantum tunneling effect leads to 3 He harvesting with high efficiency via kinetic sieving. Both the quantum tunneling effect and zero-point energy (ZPE) determine the 3 He/ 4 He separation via thermally-driven equilibrium sieving, where the ZPE effect dominates efficient 3 He/ 4 He separation between two reservoirs. The quantum effects revealed in this work suggest that the nanoporous graphenylene membrane is promising for efficient 3 He harvesting that can be exploited for industrial applications.

  12. Second sound velocities in superfluid 3He-4He solutions

    International Nuclear Information System (INIS)

    Dikina, L.S.; Kotenev, G.Ya.; Rudavskij, Eh.Ya.

    1978-01-01

    The velocities of the second sound in the superfluid He 3 -He 4 solutions were measured by the pulse method in the range of temperatures from 1.3 K to Tsub(lambda) and for He 3 concentrations up to 13%.The results obtained supplemented by those available before give the complete description of the concentration and temperature dependences of the second sound velocity in superfluid He 3 -He 4 solutions. The comprehensive comparison of the experimental data on the velocity of the second sound with the theoretical calculations for the superfluid solutions with arbitrary content of He 3 is performed. The good agreement is found between experiment and the theory. The experimental data obtained are used for determination of the potential, which determines the properties of the superfluid solutions

  13. Spin-polarized electron capture for the Na+3He2+ system at a 3He2+ impact energy of 5.33--9.33 keV/amu

    International Nuclear Information System (INIS)

    Tanaka, M.; Shimakura, N.; Ohshima, T.; Katori, K.; Fujiwara, M.; Ogata, H.; Kondo, M.

    1994-01-01

    3 He + atomic polarizations following the spin-polarized electron capture process for the N rvec a(3s)+ 3 He 2+ system were measured at 3 He 2+ impact energies from 5.33 to 9.33 keV/amu. The magnitude of the 3 He + atomic polarizations was deduced from the 3 He + nuclear polarization measured by means of beam-foil spectroscopy. The observed polarization transfer coefficient P T defined by the ratio of the 3 He + atomic polarization to the sodium one showed a pronounced reduction from unity, which was qualitatively explained by the prediction of a simple cascade photon decay model. Evidence for a further reduction of P T from the above model and a possible impact energy dependence of P T suggested an excessive depolarization due to the presence of the collision alignment parameter A 0 col of 3 He + formed by the electron capture process. In order to see this more closely, the observed P T 's were examined theoretically using the semiclassical impact parameter method, in which an 18-state molecular expansion was employed, and atomic-type electron translation effects were rigorously taken into account. Ensuring that both the absolute values and the impact energy dependence of the observed capture cross sections were remarkably well reproduced by the calculations in which the states up to 4f in 3 He + were introduced, it was demonstrated that the calculated results for P T qualitatively reproduced not only the absolute values of the observed P T 's but also their gentle decrease with increasing impact energy. Production of nuclear polarizations resulting from the polarized electron capture processes between multicharged heavy ions and alkaline-earth-metal atoms is an example of one use of the future project of universal polarized heavy-ion sources

  14. Energy Reflection Coefficients for 5-10 keV He Ions Incident on Au, Ag, and Cu

    DEFF Research Database (Denmark)

    Schou, Jørgen; Sørensen, H.; Littmark, U.

    1978-01-01

    The calorimetric deuterium-film method was used for measurements of the energy reflection coefficient γ for normal incidence of 5-10 keV He ions on Cu, Ag and Au. A theoretical calculation of γ by means of transport theory gives fair agreement with the experimental results. The experimental data...... the experimental and theoretical results for the He ions are in acceptable agreement with other experimental and theoretical results. For He ions, the experimental γ-values are 20-30% above the values for hydrogen ions for the same value of ε...

  15. Renal MR angiography and perfusion in the pig using hyperpolarized water.

    Science.gov (United States)

    Wigh Lipsø, Kasper; Hansen, Esben Søvsø Szocska; Tougaard, Rasmus Stilling; Laustsen, Christoffer; Ardenkjaer-Larsen, Jan Henrik

    2017-09-01

    To study hyperpolarized water as an angiography and perfusion tracer in a large animal model. Protons dissolved in deuterium oxide (D 2 O) were hyperpolarized in a SPINlab dissolution dynamic nuclear polarization (dDNP) polarizer and subsequently investigated in vivo in a pig model at 3 Tesla (T). Approximately 15 mL of hyperpolarized water was injected in the renal artery by hand over 4-5 s. A liquid state polarization of 5.3 ± 0.9% of 3.8 M protons in 15 mL of deuterium oxide was achieved with a T 1 of 24 ± 1 s. This allowed injection through an arterial catheter into the renal artery and subsequently high-contrast imaging of the entire kidney parenchyma over several seconds. The dynamic images allow quantification of tissue perfusion, with a mean cortical perfusion of 504 ± 123 mL/100 mL/min. Hyperpolarized water MR imaging was successfully demonstrated as a renal angiography and perfusion method. Quantitative perfusion maps of the kidney were obtained in agreement with literature and control experiments with gadolinium contrast. Magn Reson Med 78:1131-1135, 2017. © 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.

  16. Calculation of the dispersion-dipole coefficients for interactions between H, He, and H2

    International Nuclear Information System (INIS)

    Bishop, D.M.; Pipin, J.

    1993-01-01

    Collisions between atoms and molecules create an induced dipole moment which, at long range separations, stems, in part, from the van der Waals interactions between the colliding species. This contribution is known as the dispersion dipole moment and is of the order R -7 , where R is the separation between particles. Although there have been several approximate calculations of the dispersion-dipole coefficients which govern this contribution, and are the counterparts to the van der Waals dispersion-energy coefficients, there have been few ab initio calculations. In this article we present highly accurate results, based on explicitly electron-correlated wave functions, for the dispersion-dipole coefficients pertaining to interactions between pairs chosen from H, He, and H 2 . We also obtain values with some of the currently used approximate formulas. A comparison shows that these values differ, in general, by a significant amount (∼20--∼40 %) from the accurate ones. We also tabulate values of the dipole--dipole-quadrupole polarizability tensor (B) for imaginary frequency (iω) for a range of frequencies appropriate to a 64-point Gauss--Legendre quadrature for H, He, and H 2 . These values were used in certain numerical integrations we made to verify our original results which had been obtained by analytic integration---they may, however, be useful in other contexts. For H--H 2 and H 2 --H 2 , these are the only ab initio calculations of the dispersion-dipole coefficients of which we are aware

  17. Third sound resonance studies of 3He-4He mixture films

    International Nuclear Information System (INIS)

    Heinrichs, R.M.

    1985-01-01

    Third sound velocity and dissipation measurements were performed on 3 He- 4 He mixture films of 3.6 and 5.3 layers 4 He and up to 3 added layers 3 He in the temperature range 0.05-0.3 K using third sound resonance techniques. The 3 He concentration dependence of the velocity was in excellent agreement with a simple layered film model down to the lowest concentrations studied. At the higher 3 He concentrations, the velocity began to deviate from the model, rising above it. The concentration dependence of the dissipation showed some unique structure with a maximum at 0.3-0.5 layers added 3 He for both 4 He coverages. The third sound velocity in the low concentration mixture films had very little temperature dependence in the range studied. The dissipation, however, had some definite temperature dependent structure that evolved with concentration. This evolution was most pronounced at concentrations near the dissipation maximum and eventually became exponential at the higher coverages. Fitting these exponentials produced estimates of the difference in binding energy for the 3 He states in and on the film. In this higher 3 He concentration regime, a temperature dependence of the velocity was observed that began as a small peak at about 0.15 K and eventually became a step at the highest concentrations studied. The exponential nature of the dissipation became clouded when the velocity evolved into this last behavior

  18. Simultaneous PET/MRI with (13)C magnetic resonance spectroscopic imaging (hyperPET): phantom-based evaluation of PET quantification.

    Science.gov (United States)

    Hansen, Adam E; Andersen, Flemming L; Henriksen, Sarah T; Vignaud, Alexandre; Ardenkjaer-Larsen, Jan H; Højgaard, Liselotte; Kjaer, Andreas; Klausen, Thomas L

    2016-12-01

    Integrated PET/MRI with hyperpolarized (13)C magnetic resonance spectroscopic imaging ((13)C-MRSI) offers simultaneous, dual-modality metabolic imaging. A prerequisite for the use of simultaneous imaging is the absence of interference between the two modalities. This has been documented for a clinical whole-body system using simultaneous (1)H-MRI and PET but never for (13)C-MRSI and PET. Here, the feasibility of simultaneous PET and (13)C-MRSI as well as hyperpolarized (13)C-MRSI in an integrated whole-body PET/MRI hybrid scanner is evaluated using phantom experiments. Combined PET and (13)C-MRSI phantoms including a NEMA [(18)F]-FDG phantom, (13)C-acetate and (13)C-urea sources, and hyperpolarized (13)C-pyruvate were imaged repeatedly with PET and/or (13)C-MRSI. Measurements evaluated for interference effects included PET activity values in the largest sphere and a background region; total number of PET trues; and (13)C-MRSI signal-to-noise ratio (SNR) for urea and acetate phantoms. Differences between measurement conditions were evaluated using t tests. PET and (13)C-MRSI data acquisition could be performed simultaneously without any discernible artifacts. The average difference in PET activity between acquisitions with and without simultaneous (13)C-MRSI was 0.83 (largest sphere) and -0.76 % (background). The average difference in net trues was -0.01 %. The average difference in (13)C-MRSI SNR between acquisitions with and without simultaneous PET ranged from -2.28 to 1.21 % for all phantoms and measurement conditions. No differences were significant. The system was capable of (13)C-MRSI of hyperpolarized (13)C-pyruvate. Simultaneous PET and (13)C-MRSI in an integrated whole-body PET/MRI hybrid scanner is feasible. Phantom experiments showed that possible interference effects introduced by acquiring data from the two modalities simultaneously are small and non-significant. Further experiments can now investigate the benefits of simultaneous PET and

  19. A magnetic tunnel to shelter hyperpolarized fluids

    International Nuclear Information System (INIS)

    Milani, Jonas; Vuichoud, Basile; Bornet, Aurélien; Miéville, Pascal; Mottier, Roger; Jannin, Sami; Bodenhausen, Geoffrey

    2015-01-01

    To shield solutions carrying hyperpolarized nuclear magnetization from rapid relaxation during transfer through low fields, the transfer duct can be threaded through an array of permanent magnets. The advantages are illustrated for solutions containing hyperpolarized 1 H and 13 C nuclei in a variety of molecules

  20. A magnetic tunnel to shelter hyperpolarized fluids

    Energy Technology Data Exchange (ETDEWEB)

    Milani, Jonas, E-mail: jonas.milani@epfl.ch; Vuichoud, Basile; Bornet, Aurélien; Miéville, Pascal; Mottier, Roger [Institut des Sciences et Ingénierie Chimiques, Ecole Polytechnique Fédérale de Lausanne (EPFL), Batochime, CH-1015 Lausanne (Switzerland); Jannin, Sami [Institut des Sciences et Ingénierie Chimiques, Ecole Polytechnique Fédérale de Lausanne (EPFL), Batochime, CH-1015 Lausanne (Switzerland); Bruker BioSpin AG, Industriestrasse 26, CH-8117 Fällanden (Switzerland); Bodenhausen, Geoffrey [Institut des Sciences et Ingénierie Chimiques, Ecole Polytechnique Fédérale de Lausanne (EPFL), Batochime, CH-1015 Lausanne (Switzerland); Département de Chimie, École Normale Supérieure-PSL Research University, 24 rue Lhomond, F-75005 Paris (France); Sorbonne Universités, UPMC Univ Paris 06, LBM, 4 place Jussieu, F-75005 Paris (France); CNRS, UMR 7203 LBM, F-75005 Paris (France)

    2015-02-15

    To shield solutions carrying hyperpolarized nuclear magnetization from rapid relaxation during transfer through low fields, the transfer duct can be threaded through an array of permanent magnets. The advantages are illustrated for solutions containing hyperpolarized {sup 1}H and {sup 13}C nuclei in a variety of molecules.

  1. Pathway to cryogen free production of hyperpolarized Krypton-83 and Xenon-129.

    Directory of Open Access Journals (Sweden)

    Joseph S Six

    Full Text Available Hyperpolarized (hp (129Xe and hp (83Kr for magnetic resonance imaging (MRI are typically obtained through spin-exchange optical pumping (SEOP in gas mixtures with dilute concentrations of the respective noble gas. The usage of dilute noble gases mixtures requires cryogenic gas separation after SEOP, a step that makes clinical and preclinical applications of hp (129Xe MRI cumbersome. For hp (83Kr MRI, cryogenic concentration is not practical due to depolarization that is caused by quadrupolar relaxation in the condensed phase. In this work, the concept of stopped flow SEOP with concentrated noble gas mixtures at low pressures was explored using a laser with 23.3 W of output power and 0.25 nm linewidth. For (129Xe SEOP without cryogenic separation, the highest obtained MR signal intensity from the hp xenon-nitrogen gas mixture was equivalent to that arising from 15.5±1.9% spin polarized (129Xe in pure xenon gas. The production rate of the hp gas mixture, measured at 298 K, was 1.8 cm(3/min. For hp (83Kr, the equivalent of 4.4±0.5% spin polarization in pure krypton at a production rate of 2 cm(3/min was produced. The general dependency of spin polarization upon gas pressure obtained in stopped flow SEOP is reported for various noble gas concentrations. Aspects of SEOP specific to the two noble gas isotopes are discussed and compared with current theoretical opinions. A non-linear pressure broadening of the Rb D(1 transition was observed and taken into account for the qualitative description of the SEOP process.

  2. Pathway to cryogen free production of hyperpolarized Krypton-83 and Xenon-129.

    Science.gov (United States)

    Six, Joseph S; Hughes-Riley, Theodore; Stupic, Karl F; Pavlovskaya, Galina E; Meersmann, Thomas

    2012-01-01

    Hyperpolarized (hp) (129)Xe and hp (83)Kr for magnetic resonance imaging (MRI) are typically obtained through spin-exchange optical pumping (SEOP) in gas mixtures with dilute concentrations of the respective noble gas. The usage of dilute noble gases mixtures requires cryogenic gas separation after SEOP, a step that makes clinical and preclinical applications of hp (129)Xe MRI cumbersome. For hp (83)Kr MRI, cryogenic concentration is not practical due to depolarization that is caused by quadrupolar relaxation in the condensed phase. In this work, the concept of stopped flow SEOP with concentrated noble gas mixtures at low pressures was explored using a laser with 23.3 W of output power and 0.25 nm linewidth. For (129)Xe SEOP without cryogenic separation, the highest obtained MR signal intensity from the hp xenon-nitrogen gas mixture was equivalent to that arising from 15.5±1.9% spin polarized (129)Xe in pure xenon gas. The production rate of the hp gas mixture, measured at 298 K, was 1.8 cm(3)/min. For hp (83)Kr, the equivalent of 4.4±0.5% spin polarization in pure krypton at a production rate of 2 cm(3)/min was produced. The general dependency of spin polarization upon gas pressure obtained in stopped flow SEOP is reported for various noble gas concentrations. Aspects of SEOP specific to the two noble gas isotopes are discussed and compared with current theoretical opinions. A non-linear pressure broadening of the Rb D(1) transition was observed and taken into account for the qualitative description of the SEOP process.

  3. Hyperpolarized H2O MR angiography

    DEFF Research Database (Denmark)

    Ardenkjær-Larsen, Jan Henrik; Laustsen, Christoffer; Bowen, Sean

    2014-01-01

    polarization followed by dissolution in D2O. A water 1H signal enhancement of 77 times compared with 4.7 Tesla was obtained. This corresponds to a polarization of 3.5% for the 3.9 mol/L 1H in D2O . Moreover, a T1 in excess of 20 s was achieved. The use of hyperpolarized water as a contrast agent presents a new...

  4. Photodisintegration of 3H and 3He

    International Nuclear Information System (INIS)

    Faul, D.D.

    1980-09-01

    The photoneutron cross sections for 3 H and 3 He have been measured from threshold to approx. 25 MeV with monoenergetic photons from the annihilation in flight of fast positrons at the LLL Electron-Positron Linear Accelerator facility. These reactions include the two-body breakup of 3 H and the three-body breakup of both 3 H and 3 He; these measurements for 3 H are the first to span the energy region across the peaks of the cross sections. An efficient BF 3 -tube-and-paraffin neutron detector and high-pressure gaseous samples of several moles each (the activity of the 3 H sample was approx. 200,000 Ci) were employed in these measurements. Measurements on 16 O and 2 H also were performed to verify the absolute cross-section scale. The results, when compared with each other and with results for the two-body breakup cross section for 3 He from the literature, show that the two-body breakup cross sections for 3 H and 3 He have nearly the same shape, but the one for 3 He lies lower in magnitude; the three-body breakup cross section for 3 He lies higher in magnitude and is broader in the peak region and also rises less sharply from threshold than that for 3 H; and these measured differences between the cross sections for the breakup modes largely compensate in their sum, so that the total photon absorption cross sections for 3 H and 3 He are nearly the same in both size and shape at energies near and above their peaks. Theoretical results from the literature disagree with the experimental results to a certain extent over the entire photon-energy region for which the photoneutron cross sections were measured. 50 figures, 7 tables

  5. A hybrid multibreath wash-in wash-out lung function quantification scheme in human subjects using hyperpolarized 3 He MRI for simultaneous assessment of specific ventilation, alveolar oxygen tension, oxygen uptake, and air trapping.

    Science.gov (United States)

    Hamedani, Hooman; Kadlecek, Stephen; Xin, Yi; Siddiqui, Sarmad; Gatens, Heather; Naji, Joseph; Ishii, Masaru; Cereda, Maurizio; Rossman, Milton; Rizi, Rahim

    2017-08-01

    To present a method for simultaneous acquisition of alveolar oxygen tension (P A O 2 ), specific ventilation (SV), and apparent diffusion coefficient (ADC) of hyperpolarized (HP) gas in the human lung, allowing reinterpretation of the P A O 2 and SV maps to produce a map of oxygen uptake (R). An imaging scheme was designed with a series of identical normoxic HP gas wash-in breaths to measure ADC, SV, P A O 2 , and R in less than 2 min. Signal dynamics were fit to an iterative recursive model that regionally solved for these parameters. This measurement was successfully performed in 12 subjects classified in three healthy, smoker, and chronic obstructive pulmonary disease (COPD) cohorts. The overall whole lung ADC, SV, P A O 2 , and R in healthy, smoker, and COPD subjects was 0.20 ± 0.03 cm 2 /s, 0.39 ± 0.06,113 ± 2 Torr, and 1.55 ± 0.35 Torr/s, respectively, in healthy subjects; 0.21 ± 0.03 cm 2 /s, 0.33 ± 0.06, 115.9 ± 4 Torr, and 0.97 ± 0.2 Torr/s, respectively, in smokers; and 0.25 ± 0.06 cm 2 /s, 0.23 ± 0.08, 114.8 ± 6.0Torr, and 0.94 ± 0.12 Torr/s, respectively, in subjects with COPD. Hetrogeneity of SV, P A O 2 , and R were indicators of both smoking-related changes and disease, and the severity of the disease correlated with the degree of this heterogeneity. Subjects with symptoms showed reduced oxygen uptake and specific ventilation. High-resolution, nearly coregistered and quantitative measures of lung function and structure were obtained with less than 1 L of HP gas. This hybrid multibreath technique produced measures of lung function that revealed clear differences among the cohorts and subjects and were confirmed by correlations with global lung measurements. Magn Reson Med 78:611-624, 2017. © 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.

  6. The 3He Supply Problem

    Energy Technology Data Exchange (ETDEWEB)

    Kouzes, Richard T.

    2009-05-01

    One of the main uses for 3He is in gas proportional counters for neutron detection. Radiation portal monitors deployed for homeland security and non-proliferation use such detectors. Other uses of 3He are for research detectors, commercial instruments, well logging detectors, dilution refrigerators, for targets or cooling in nuclear research, and for basic research in condensed matter physics. The US supply of 3He comes almost entirely from the decay of tritium used in nuclear weapons by the US and Russia. A few other countries contribute a small amount to the world’s 3He supply. Due to the large increase in use of 3He for homeland security, the supply has dwindled, and can no longer meet the demand. This white paper reviews the problems of supply, utilization, and alternatives.

  7. Lung morphometry using hyperpolarized 129 Xe multi-b diffusion MRI with compressed sensing in healthy subjects and patients with COPD.

    Science.gov (United States)

    Zhang, Huiting; Xie, Junshuai; Xiao, Sa; Zhao, Xiuchao; Zhang, Ming; Shi, Lei; Wang, Ke; Wu, Guangyao; Sun, Xianping; Ye, Chaohui; Zhou, Xin

    2018-05-04

    To demonstrate the feasibility of compressed sensing (CS) to accelerate the acquisition of hyperpolarized (HP) 129 Xe multi-b diffusion MRI for quantitative assessments of lung microstructural morphometry. Six healthy subjects and six chronic obstructive pulmonary disease (COPD) subjects underwent HP 129 Xe multi-b diffusion MRI (b = 0, 10, 20, 30, and 40 s/cm 2 ). First, a fully sampled (FS) acquisition of HP 129 Xe multi-b diffusion MRI was conducted in one healthy subject. The acquired FS dataset was retrospectively undersampled in the phase encoding direction, and an optimal twofold undersampled pattern was then obtained by minimizing mean absolute error (MAE) between retrospective CS (rCS) and FS MR images. Next, the FS and CS acquisitions during separate breath holds were performed on five healthy subjects (including the above one). Additionally, the FS and CS synchronous acquisitions during a single breath hold were performed on the sixth healthy subject and one COPD subject. However, only CS acquisitions were conducted in the rest of the five COPD subjects. Finally, all the acquired FS, rCS and CS MR images were used to obtain morphometric parameters, including acinar duct radius (R), acinar lumen radius (r), alveolar sleeve depth (h), mean linear intercept (L m ), and surface-to-volume ratio (SVR). The Wilcoxon signed-rank test and the Bland-Altman plot were employed to assess the fidelity of the CS reconstruction. Moreover, the t-test was used to demonstrate the effectiveness of the multi-b diffusion MRI with CS in clinical applications. The retrospective results demonstrated that there was no statistically significant difference between rCS and FS measurements using the Wilcoxon signed-rank test (P > 0.05). Good agreement between measurements obtained with the CS and FS acquisitions during separate breath holds was demonstrated in Bland-Altman plots of slice differences. Specifically, the mean biases of the R, r, h, L m , and SVR between the CS and

  8. Dynamics of phase-separated 3He-4He films

    International Nuclear Information System (INIS)

    Kurihara, Susumu

    1982-01-01

    A froehlich-type Hamiltonian is derived for third sound and 3 He quasi particles in phase-separated double layer of superfluid 4 He and normal 3 He liquid. It is stressed that our system is unique and valuable in that characteristic parameters can be varied in a wide range, simply by adjusting the film thickness. The effect of fermion-boson coupling on the velocity and damping of the third sound is examined. It is predicted that a rather drastic change in the third sound spectrum will occur when the Fermi velocity of 3 He system and the third sound velocity are nearly the same. It is pointed out that the system under consideration may show a variety of interesting phenomena, in addition to the softening of the third sound. (author)

  9. Analyzing Power of 3He(n, n)3He Between 1.60 and 5.54 MeV

    International Nuclear Information System (INIS)

    Esterline, J.; Tornow, W.

    2013-01-01

    We report the measurements of the analyzing power A y (θ) of n- 3 He elastic scattering with unprecedented accuracy and angular coverage at five incident neutron energies between 1.60 and 5.54 MeV. To this end, we employed the polarization-transfer reactions 3 H(p, n) 3 He and 2 H(d, n) 3 He at 0 ° for neutron generation and a recently developed high-pressure 3 He gas scintillator as an active target, enabling neutron-time-of-flight and 3 He recoil-energy determinations. We obtained simultaneously the neutron polarization with a 4 He-based polarimeter, capitalizing on the well-known n- 4 He A y (θ). Our n- 3 He A y (θ) data are compared to rigorous four-nucleon calculations using high-precision nucleon–nucleon potential models. The agreement between data and calculations is fair at the lower energies and becomes less satisfactory with increasing neutron energy. However, in comparison to the pure isotriplet p- 3 He system in the same energy region, the agreement between measured and calculated A y is much better for the mixed (isotriplet and isosinglet) n- 3 He system, indicating large and somewhat counterintuitive isospin effects. We note that the incorporation of a Δ-mediated three-nucleon force in calculations of n- 3 He scattering was found to affect A y (θ) negligibly, suggesting the need for the reconsideration of fundamental interactions in resolving the four-nucleon analyzing power puzzle first established about a decade ago in p- 3 He scattering. (author)

  10. Cosmogenic 3He in detrital gold

    Science.gov (United States)

    Stuart, Finlay; Yakubovich, Olga; Caracedo, Ana; Nesterenok, Alexander

    2017-04-01

    Since the measurement of cosmogenic He in an alluvial diamond by McConville and Reynolds (1996) the application of cosmogenic noble gases to individual detrital grains to quantify surface processes has not been vigorously pursued. The likely low rate of diffusion of cosmogenic He in native metals, and their resistance to weathering and disintegration during erosion and transport, makes them a potential record of long-term Earth surface processes. In an effort to assess the extent that detrital refractory metals record the exposure history during transport and storage we have undertaken a reconnaissance study of the He isotope composition in 18 grains (2-200 mg) of native gold, copper, silver, and PtPd, Pt3Fe and OsIr alloys from alluvial placer deposits from around the world. 4He is dominantly the result of U and Th decay within the grains, or decay of 190Pt in the Pt-rich alloys. 3He is measurable in 13 grains, concentrations range up to 2.7E+6 atoms/g. 3He/4He are always in excess of the crustal radiogenic ratio, up to 306 Ra. Although nucleogenic 3He produced by (n,α) reactions on 6Li, and 3He from trapped hydrothermal fluids, are present, the majority of the 3He is cosmogenic in origin. Using newly calculated cosmogenic 3He production rates in heavy metals, and a determination of the effect of implantation based on the stopping distances of spallogenic 3He and 3H, the grains have 3Hecos concentrations that are equivalent to 0.35 to 1.5 Ma exposure at Earth's surface. In a study of detrital gold grains from several sites in Scotland we have found that 10 % have 3He concentrations that are significantly in excess of that generated since the Last Glacial Maximum. These studies demonstrate that, with refinement, cosmogenic 3He in refractory detrital minerals can be used to quantify sediment transport and storage on the 1-10 Ma timescale. P. McConville & J.H. Reynolds (1989). Geochim. Cosmochim. Acta, 53, 2365-75.

  11. Annihilation of antiprotons at rest in 3He and 4He

    International Nuclear Information System (INIS)

    Balestra, F.; Bossolasco, S.; Bussa, M.P.; Busso, L.; Fava, L.; Ferrero, L.; Panzieri, D.; Piragino, G.; Tosello, F.; Bendiscioli, G.; Rotondi, R.; Salvini, P.; Zenoni, A.; Batusov, Y.A.; Bunyatov, S.A.; Falomkin, I.V.; Nichitiu, F.; Pontecorvo, G.B.; Sapozhnikov, M.G.; Tretyak, V.I.; Guaraldo, C.; Maggiora, A.; Haatuft, A.; Halsteinslid, A.; Myklebost, K.; Olsen, J.M.; Breivik, F.O.; Jacobsen, T.; Sorensen, S.O.

    1987-01-01

    At LEAR of CERN the annihilation of antiprotons stopping in 3 He and 4 He filling a self shunted streamer chamber in magnetic field has been studied. The relative probabilities of π - production in anti p 3 He and anti p 4 He annihilation events have been obtained. The ratio between the anti p annihilation probability on the neutron and on the proton for 3 He and 4 He has been deduced to be about half the value obtained for 2 H in bubble chamber experiments. The analysis of the results shows this difference cannot be ascribed only to the pion final state interaction or to the shadow effect of the nucleons in the nuclei. 9 refs.; 2 figs

  12. (3He,xn), (3He,pxn) and (3He, fission) reactions on 206Pb between 80 and 200MeV

    International Nuclear Information System (INIS)

    Andre, C.; Gauvin, H.; Le Beyec, Y.; Porile, N.T.

    1976-01-01

    The reactions induced in 206 Pb by 3 He particles having energies between 80 and 200MeV have been studied. Excitation functions for ( 3 He,xn) with x=3 to 14 and for ( 3 He,pxn) with x=2 to 5 have been obtained. Angular distributions of fission fragments were measured at 100, 125, 150 and 175MeV and total fission cross-sections were deduced from the data. On the basis of these results, analysis is attempted to examine the characteristics of reaction mechanisms. From these results it is concluded that non-compound processes play an important role in the reactions. Two features are characteristic of these processes: large cross-sections for charged particle emission and angular distribution of fission fragments closed to isotropy in the laboratory system. In the energy range 25 to 45MeV/nucleon, a comparison was made between the present results and those from an experimental study of α-particle induced reactions on 206 Pb. Also a comparison was made with an α-nucleus collision model applied to 206 Pb. All the observations strongly suggest a breakup of the projectile 3 He followed by the interactions of the fragments with the target nucleus [fr

  13. Reflection and transformation of acoustic waves at the interface in superfluid 3He-A

    International Nuclear Information System (INIS)

    Kekutiya, Sh.E.; Chkhaidze, N.D.

    1997-01-01

    Reflection and transformation of acoustic waves in 3 He-A and 3 He-A 1 are considered for two cases: (1) at the boundary with a solid impermeable wall at an arbitrary angle of incidence of a wave and (2) for normal incidence of waves on the interface between a free liquid and a system of periodic plane-parallel capillaries filling the semi-space. For the first case we have calculated the reflection coefficients of the first and the second sounds and spin and spin-temperature waves as well as the coefficients of transformation of these waves into each other. It is shown that the longitudinal wave undergoes no transformation into other waves, there occurs instead its complete reflection from the solid wall. The angle of incidence at which the energy attenuation coefficient of the first sound is maximum, and the interval of angles corresponding to the attenuation and the total interval reflection of the second sound are estimated. For the second case we have obtained: the coefficients of excitation of the fourth sound and the magneto-acoustic wave by the first and the second sounds; the reflection coefficients for the first and the second sounds and the longitudinal spin wave; the coefficient of transformation of the first sound into the second one and vice versa; the coefficient of reflection of the fourth sound from the capillary system - free liquid interface; the coefficient of excitation of longitudinal spin wave in free helium by the same wave in a capillary

  14. FAST TRACK COMMUNICATION: Recombination of H+3 ions in the afterglow of a He Ar H2 plasma

    Science.gov (United States)

    Glosik, J.; Korolov, I.; Plasil, R.; Novotny, O.; Kotrik, T.; Hlavenka, P.; Varju, J.; Mikhailov, I. A.; Kokoouline, V.; Greene, Chris H.

    2008-10-01

    Recombination of H+3 with electrons is studied in a low-temperature plasma containing He, H2 and Ar at different He and H2 densities. The effective plasma recombination rate is driven by binary, H+3 + e-, and ternary, H+3 + e-+ He, processes with the rate coefficients 7.5 × 10-8 cm3 s-1 and 2.8 × 10-25 cm6 s-1 respectively at 260 K. We suggest that the ternary recombination involves formation of neutral highly excited Rydberg H3 followed by an l-changing collision with He. The difference between recombination of para- and ortho-H+3 is discussed.

  15. Study of the sup 3 H( sup 3 H, 2n) sup 4 He and sup 3 He( sup 3 He, 2p) sup 4 He reactions in the framework of three-cluster microscopic model

    CERN Document Server

    Vasilevsky, V S; Arickx, F; Broeckhove, J

    2002-01-01

    The reactions sup 3 H( sup 3 H, 2n) sup 4 He and sup 3 He( sup 3 He, 2p) sup 4 He are investigated within a fully microscopic cluster model featuring a three-cluster exit channel. A Hyperspherical Harmonics basis is used to describe the three-cluster continuum. The resulting astrophysical s-factor of both reactions is in good agreement with experimental data. Analysis of the low-energy scattering parameters reveals no evidence for a hidden resonance state would increase the cross-section of the reactions, and would help to resolve the solar neutrino problem.

  16. Multiparametric and molecular imaging of breast tumors with MRI and PET/MRI

    International Nuclear Information System (INIS)

    Pinker, K.; Marino, M.A.; Meyer-Baese, A.; Helbich, T.H.

    2016-01-01

    Magnetic resonance imaging (MRI) of the breast is an indispensable tool in breast imaging for many indications. Several functional parameters with MRI and positron emission tomography (PET) have been assessed for imaging of breast tumors and their combined application is defined as multiparametric imaging. Available data suggest that multiparametric imaging using different functional MRI and PET parameters can provide detailed information about the hallmarks of cancer and may provide additional specificity. Multiparametric and molecular imaging of the breast comprises established MRI parameters, such as dynamic contrast-enhanced MRI, diffusion-weighted imaging (DWI), MR proton spectroscopy ( 1 H-MRSI) as well as combinations of radiological and MRI techniques (e.g. PET/CT and PET/MRI) using radiotracers, such as fluorodeoxyglucose (FDG). Multiparametric and molecular imaging of the breast can be performed at different field-strengths (range 1.5-7 T). Emerging parameters comprise novel promising techniques, such as sodium imaging ( 23 Na MRI), phosphorus spectroscopy ( 31 P-MRSI), chemical exchange saturation transfer (CEST) imaging, blood oxygen level-dependent (BOLD) and hyperpolarized MRI as well as various specific radiotracers. Multiparametric and molecular imaging has multiple applications in breast imaging. Multiparametric and molecular imaging of the breast is an evolving field that will enable improved detection, characterization, staging and monitoring for personalized medicine in breast cancer. (orig.) [de

  17. Thermometry in 3He

    International Nuclear Information System (INIS)

    Richardson, R.C.

    1977-01-01

    Some of the methods used in measuring the temperatures of the transitions in 3 He are reviewed. Although noise thermometers, γ-ray anisotropy thermometers and even Pt NMR thermometers are satisfactory for furnishing temperature standards, they are not satisfactory secondary thermometers. The susceptibility of CMN and various 3 He properties make more precise and quicker thermometric indications. (Auth.)

  18. Simultaneous Hyperpolarized 13C-Pyruvate MRI and 18F-FDG PET (HyperPET) in 10 Dogs with Cancer

    DEFF Research Database (Denmark)

    Gutte, Henrik; Hansen, Adam E; Larsen, Majbrit M E

    2015-01-01

    with biopsy-verified spontaneous malignant tumors were included for imaging. All dogs underwent a protocol of simultaneous (18)F-FDG PET, anatomic MR, and hyperpolarized dynamic nuclear polarization with (13)C-pyruvate imaging. The data were acquired using a combined clinical PET/MR imaging scanner. We found...... that combined (18)F-FDG PET and (13)C-pyruvate MRS imaging was possible in a single session of approximately 2 h. A continuous workflow was obtained with the injection of (18)F-FDG when the dogs was placed in the PET/MR scanner. (13)C-MRS dynamic acquisition demonstrated in an axial slab increased (13)C......With the introduction of combined PET/MR spectroscopic (MRS) imaging, it is now possible to directly and indirectly image the Warburg effect with hyperpolarized (13)C-pyruvate and (18)F-FDG PET imaging, respectively, via a technique we have named hyperPET. The main purpose of this present study...

  19. Δ excitation in 3He and 4He by photons

    International Nuclear Information System (INIS)

    Maruyama, Koichi.

    1993-06-01

    The use of the 3 He and 4 He photodisintegration reactions in the study of the excitation, propagation, and decay of the Δ (1232) in these nuclei is proposed. By using the data obtained with TAGX for both photon absorption on neutron-proton pairs and complete photodisintegration, we find no compelling evidence for the change of the Δ property in the 3 He and 4 He nuclei. It is also proposed to use nuclear photodisintegration in the search for the excitation of the higher-mass nucleon resonances whose absence in the total photon-absorption cross sections in nuclei is reported recently. (author)

  20. MRI-based 3D pelvic autonomous innervation: a first step towards image-guided pelvic surgery

    Energy Technology Data Exchange (ETDEWEB)

    Bertrand, M.M. [University Montpellier I, Laboratory of Experimental Anatomy Faculty of Medicine Montpellier-Nimes, Montpellier (France); Macri, F.; Beregi, J.P. [Nimes University Hospital, University Montpellier 1, Radiology Department, Nimes (France); Mazars, R.; Prudhomme, M. [University Montpellier I, Laboratory of Experimental Anatomy Faculty of Medicine Montpellier-Nimes, Montpellier (France); Nimes University Hospital, University Montpellier 1, Digestive Surgery Department, Nimes (France); Droupy, S. [Nimes University Hospital, University Montpellier 1, Urology-Andrology Department, Nimes (France)

    2014-08-15

    To analyse pelvic autonomous innervation with magnetic resonance imaging (MRI) in comparison with anatomical macroscopic dissection on cadavers. Pelvic MRI was performed in eight adult human cadavers (five men and three women) using a total of four sequences each: T1, T1 fat saturation, T2, diffusion weighed. Images were analysed with segmentation software in order to extract nervous tissue. Key height points of the pelvis autonomous innervation were located in every specimen. Standardised pelvis dissections were then performed. Distances between the same key points and the three anatomical references forming a coordinate system were measured on MRIs and dissections. Concordance (Lin's concordance correlation coefficient) between MRI and dissection was calculated. MRI acquisition allowed an adequate visualization of the autonomous innervation. Comparison between 3D MRI images and dissection showed concordant pictures. The statistical analysis showed a mean difference of less than 1 cm between MRI and dissection measures and a correct concordance correlation coefficient on at least two coordinates for each point. Our acquisition and post-processing method demonstrated that MRI is suitable for detection of autonomous pelvic innervations and can offer a preoperative nerve cartography. (orig.)

  1. The Gini coefficient: a methodological pilot study to assess fetal brain development employing postmortem diffusion MRI

    International Nuclear Information System (INIS)

    Viehweger, Adrian; Sorge, Ina; Hirsch, Wolfgang; Riffert, Till; Dhital, Bibek; Knoesche, Thomas R.; Anwander, Alfred; Stepan, Holger

    2014-01-01

    Diffusion-weighted imaging (DWI) is important in the assessment of fetal brain development. However, it is clinically challenging and time-consuming to prepare neuromorphological examinations to assess real brain age and to detect abnormalities. To demonstrate that the Gini coefficient can be a simple, intuitive parameter for modelling fetal brain development. Postmortem fetal specimens(n = 28) were evaluated by diffusion-weighted imaging (DWI) on a 3-T MRI scanner using 60 directions, 0.7-mm isotropic voxels and b-values of 0, 150, 1,600 s/mm 2 . Constrained spherical deconvolution (CSD) was used as the local diffusion model. Fractional anisotropy (FA), apparent diffusion coefficient (ADC) and complexity (CX) maps were generated. CX was defined as a novel diffusion metric. On the basis of those three parameters, the Gini coefficient was calculated. Study of fetal brain development in postmortem specimens was feasible using DWI. The Gini coefficient could be calculated for the combination of the three diffusion parameters. This multidimensional Gini coefficient correlated well with age (Adjusted R 2 = 0.59) between the ages of 17 and 26 gestational weeks. We propose a new method that uses an economics concept, the Gini coefficient, to describe the whole brain with one simple and intuitive measure, which can be used to assess the brain's developmental state. (orig.)

  2. Rate Coefficient Measurements and Theoretical Analysis of the OH + ( E) CF3CH=CHCF3 Reaction.

    Science.gov (United States)

    Baasandorj, Munkhbayar; Marshall, Paul; Waterland, Robert L; Ravishankara, Akkihebbal R; Burkholder, James B

    2018-04-25

    Rate coefficients, k, for the gas-phase reaction of the OH radical with (E) CF3CH=CHCF3 ((E)-1,1,14,4,4-hexafluoro-2-butene, HFO-1336mzz(E)) were measured over a range of temperature (211-374 K) and bath gas pressure (20-300 Torr; He, N2) using a pulsed laser photolysis-laser induced fluorescence (PLP-LIF) technique. k1(T) was independent of pressure over this range of conditions with k1(296 K) = (1.31 ± 0.15) × 10 13 cm3 molecule 1 s 1 and k1(T) = (6.94 ± 0.80) × 10 13 exp[ (496 ± 10)/T] cm3 molecule 1 s 1, where the uncertainties are 2 and the pre-exponential term includes estimated systematic error. Rate coefficients for the OD reaction were also determined over a range of temperature (262-374 K) at 100 Torr (He). The OD rate coefficients were ~15% greater than the OH values and showed similar temperature dependent behavior with k2(T) = (7.52 ± 0.44) × 10 13 exp[ (476 ± 20)/T] and k2(296 K) = (1.53 ± 0.15) × 10 13 cm3 molecule 1 s 1. The rate coefficients for reaction 1 were also measured using a relative rate technique between 296 and 375 K with k1(296 K) measured to be (1.22 ± 0.1) × 10 13 cm3 molecule 1 s 1 in agreement with the PLP-LIF results. In addition, the 296 K rate coefficient for the O3 + (E) CF3CH=CHCF3 reaction was determined to be reaction and the significant decrease in OH reactivity compared to the (Z) CF3CH=CHCF3 stereoisomer reaction. The estimated atmospheric lifetime of (E) CF3CH=CHCF3, due to loss by reaction with OH, is estimated to be ~90 days, while the actual lifetime will depend on the location and season of its emission. Infrared absorption spectra of (E) CF3CH=CHCF3 were measured and used to estimate the 100-year time horizon global warming potentials (GWP) of 32 (atmospherically well-mixed) and 14 (lifetime-adjusted).

  3. Specific heat of 4He and 3He--4He mixtures at their lambda transition

    International Nuclear Information System (INIS)

    Gasparini, F.M.; Moldover, M.R.

    1975-01-01

    We have measured the specific heat near the lambda transition of pure 4 He and of five 3 He-- 4 He mixtures up to a mole fraction of 0.39 3 He in 4 He. Our data for 4 He confirm the results of Ahlers revealing an asymmetry in the exponents above and below T/sub lambda/ when the specific heat is represented by a simple-power-law temperature dependence. Our results for these exponents (α = 0.012 plus-or-minus 0.002 and α' = -0.012 plus-or-minus 0.004) differ somewhat from Ahlers's. Our results can be reconciled with the requirement of scaling (α = α') only by supposing substantial contributions to C/sub p/ are made by singular correction terms to a simple power law. The measured specific heat of the mixtures richest in 3 He appears to be finite, continuous, and cusped at the lambda line. These qualitative features have been termed ''renormalization'' by Fisher. An analysis of our mixture data with a power-law temperature dependence does not yield a fully renormalized exponent, but rather an effective exponent. Derivatives at the lambda line were used to calculate the specific heat along paths of constant pressure and constant relative chemical potential.This specific heat behaves very much like C/sub p/ of pure 4 He, this behavior supporting the idea of universality for the specific-heat exponents. It is also true that the same asymmetry in the branches above and below T/sub lambda/ which is []bserved in pure 4 He is retained in the mixtures. The persistence of the asymmetry of C/subp//sub phi/ as one moves along the lambda line towards increasing 3 He concentration (at the saturated vapor pressure of the mixtures) is analogous to the persistence of the asymmetry of C/subp/ as one moves along the lambda line towards increasing pressure in pure 4 He

  4. Annihilation of antiprotons at rest in 3He and 4He

    International Nuclear Information System (INIS)

    Balestra, F.; Bossolasco, S.; Bussa, M.P.; Busso, L.; Fava, L.; Ferrero, L.; Panzieri, D.; Piragino, G.; Tosello, F.; Bendiscioli, G.; Rotondi, A.; Salvini, P.; Zenoni, A.; Batusov, Yu.A.; Bunyatov, S.A.; Falomkin, I.V.; Nichitiu, F.; Pontecorvo, G.B.; Sapozhnikov, M.G.; Tretyak, V.I.; Guaraldo, C.; Maggiora, A.; Haatuft, A.; Halsteinslid, A.; Myklebost, K.; Olsen, J.M.; Breivik, F.O.; Jacobsen, T.; Soerensen, S.O.

    1987-01-01

    At LEAR of CERN the annihilation of antiprotons, stopping in 3 He and 4 He filling a self-shunted streamer chamber in a magnetic field, has been studied. The charged-particle multiplicities have been measured and the relative probabilities of π - production in anti p 3 He and anti p 4 He annihilation events have been obtained. The ratio between the anti p annihilation probability on the neutron and the proton for 3 He and 4 He has been deduced to be about half the value obtained for 2 H in bubble chamber experiments. The analysis of the results shows that this difference cannot be due only to the pion final-state interaction or to the shadow effect of the nucleons of the nuclei. The probability of anti p annihilation at rest on a proton bound in the nucleus results to be twice as high as that on a bound neutron, showing the dominance of annihilation in the I=0 isospin states. (orig.)

  5. Correlation of human papillomavirus status with apparent diffusion coefficient of diffusion-weighted MRI in head and neck squamous cell carcinomas.

    Science.gov (United States)

    Driessen, Juliette P; van Bemmel, Alexander J M; van Kempen, Pauline M W; Janssen, Luuk M; Terhaard, Chris H J; Pameijer, Frank A; Willems, Stefan M; Stegeman, Inge; Grolman, Wilko; Philippens, Marielle E P

    2016-04-01

    Identification of prognostic patient characteristics in head and neck squamous cell carcinoma (HNSCC) is of great importance. Human papillomavirus (HPV)-positive HNSCCs have favorable response to (chemo)radiotherapy. Apparent diffusion coefficient, derived from diffusion-weighted MRI, has also shown to predict treatment response. The purpose of this study was to evaluate the correlation between HPV status and apparent diffusion coefficient. Seventy-three patients with histologically proven HNSCC were retrospectively analyzed. Mean pretreatment apparent diffusion coefficient was calculated by delineation of total tumor volume on diffusion-weighted MRI. HPV status was analyzed and correlated to apparent diffusion coefficient. Six HNSCCs were HPV-positive. HPV-positive HNSCC showed significantly lower apparent diffusion coefficient compared to HPV-negative. This correlation was independent of other patient characteristics. In HNSCC, positive HPV status correlates with low mean apparent diffusion coefficient. The favorable prognostic value of low pretreatment apparent diffusion coefficient might be partially attributed to patients with a positive HPV status. © 2015 Wiley Periodicals, Inc. Head Neck 38: E613-E618, 2016. © 2015 Wiley Periodicals, Inc.

  6. Measurement of the Electrical Conductivity of He3 Plasma Induced by Neutron Irradiation

    International Nuclear Information System (INIS)

    Braun, J.; Nygaard, K.

    1966-03-01

    The conductivity of a He plasma created by the inelastic reaction with thermal neutrons: 3 He + n th -> 3 H + p + 0.76 MeV is studied as a function of neutron flux, gas temperature and gas density. Using reported values of the electron mobility the electron density is calculated from experimental conductivity values. Further, by accepting a reasonable value for the mean energy lost in creating one ion-pair, the recombination coefficient is estimated. The measurements performed so far cover temperatures between 300 - 1600 K and densities between 0.25 - 1 times the density at atmospheric pressure and 300 K. The neutron flux is varied between 10 10 - 10 11 n/cm 2 /s. As a sample of results achieved at 1600 K and the lowest density (corresponding to about atmospheric pressure) and the highest neutron flux the following values are obtained for the conductivity, the electron density and the recombination coefficient respectively: σ 0.2 S/m, n e 6x10 11 /cm 3 , α = 2xl0 -10 cm 3 /s. An extrapolation of data obtained shows that the concept of neutron induced conductivity should be attractive for MHD power generation

  7. Regional and temporal variations in CO2/3He, 3He/4He and δ13C along the North Anatolian Fault Zone, Turkey

    International Nuclear Information System (INIS)

    Leeuw, G.A.M. de; Hilton, D.R.; Guelec, N.; Mutlu, H.

    2010-01-01

    New He and C relative abundance, isotope and concentration results from nine geothermal locations situated along an 800-km transect of the North Anatolian Fault Zone (NAFZ), Turkey, that were monitored during the period November 2001-November 2004, are reported. The geothermal waters were collected every 3-6 months to study possible links between temporal geochemical variations and seismic activity along the NAFZ. At the nine sample locations, the He isotope ratios range from 0.24 to 2.3R A , δ 13 C values range from -4.5 to +5.8 per mille, and CO 2 / 3 He ratios range from 5 x 10 9 to 5 x 10 14 . The following geochemical observations are noted: (1) the highest 3 He/ 4 He ratios are found near the Galatean volcanic region, in the central section of the NAFZ, (2) at each of the nine sample locations, the 3 He/ 4 He ratios are generally constant; however, CO 2 / 3 He ratios and He contents both show one order of magnitude variability, and δ 13 C values show up to ∼4 per mille variability, and (3) at all locations (except Resadiye), δ 13 C values show positive correlations with CO 2 contents. The results indicate that at least three processes are necessary to account for the geochemical variations: (1) binary mixing between crustal and mantle-derived volatiles can explain the general characteristics of 3 He/ 4 He ratios, δ 13 C values, and CO 2 / 3 He ratios at the nine sample locations; (2) preferential degassing of He from the geothermal waters is responsible for variations in CO 2 / 3 He values and He contents at each sample location; and (3) CO 2 dissolution followed by calcite precipitation is responsible for variations in CO 2 contents and δ 13 C values at most locations. For each of the geochemical parameters, anomalies are defined in the temporal record by values that fall outside two standard deviations of average values at each specific location. Geochemical anomalies that may be related to seismic activity are recorded on June 28, 2004 at Yalova

  8. Accelerated Fractional Ventilation Imaging with Hyperpolarized Gas MRI

    Science.gov (United States)

    Emami, Kiarash; Xu, Yinan; Hamedani, Hooman; Profka, Harrilla; Kadlecek, Stephen; Xin, Yi; Ishii, Masaru; Rizi, Rahim R.

    2013-01-01

    PURPOSE To investigate the utility of accelerated imaging to enhance multi-breath fractional ventilation (r) measurement accuracy using HP gas MRI. Undersampling shortens the breath-hold time, thereby reducing the O2-induced signal decay and allows subjects to maintain a more physiologically relevant breathing pattern. Additionally it may improve r estimation accuracy by reducing RF destruction of HP gas. METHODS Image acceleration was achieved by using an 8-channel phased array coil. Undersampled image acquisition was simulated in a series of ventilation images and images were reconstructed for various matrix sizes (48–128) using GRAPPA. Parallel accelerated r imaging was also performed on five mechanically ventilated pigs. RESULTS Optimal acceleration factor was fairly invariable (2.0–2.2×) over the range of simulated resolutions. Estimation accuracy progressively improved with higher resolutions (39–51% error reduction). In vivo r values were not significantly different between the two methods: 0.27±0.09, 0.35±0.06, 0.40±0.04 (standard) versus 0.23±0.05, 0.34±0.03, 0.37±0.02 (accelerated); for anterior, medial and posterior slices, respectively, whereas the corresponding vertical r gradients were significant (P fractional ventilation measurement with HP gas MRI. PMID:23400938

  9. 3He(d,p)4He reaction calculation with three-body Faddeev equations

    International Nuclear Information System (INIS)

    Oryu, S.; Uzu, E.; Sunahara, H.; Yamada, T.; Tabaru, G.; Hino, T.

    1998-01-01

    In order to investigate the 3 He-n-p system as a three-body problem, we have formulated 3 He-n and 3 H-p effective potentials using both a microscopic treatment and a phenomenological approach. In the microscopic treatment, potentials are generated by means of the resonating group method (RGM) based on the Minnesota nucleon-nucleon potential. These potentials are converted into separable form by means of the microscopic Pauli correct (MPC) method. The MPC potentials are properly formulated to avoid Pauli forbidden states. The phenomenological potentials are obtained by modifying parameters of the EST approximation to the Paris nucleon-nucleon potential, such that they fit the low-energy 3 He-n, 3 H-p, and 3 He-p phase shifts. Therefore, they describe the 3 He-n differential cross section, the polarization observables, and the energy levels of 4 He. The 3 He-n-p Faddeev equations are solved numerically. We reproduce correctly the ground state and the first excited state of 5 Li. Furthermore, the Paris-type potential is used to investigate the 3 He(d,p) 4 He reaction at a deuteron bombarding energy of 270 MeV, where the system is treated as a three-body problem. Results for the polarized and unpolarized differential cross sections demonstrate convergence of the Born series. (orig.)

  10. Mobility of ions trapped on vortex lines in pure 4He and 3He--4He solutions

    International Nuclear Information System (INIS)

    Ostermeier, R.M.; Glaberson, W.I.

    1976-01-01

    Measurements have been made of the mobility of positive and negative ions trapped on vortex lines in pure 4 He and dilute 3 He-- 4 He solutions over the temperature range 1.6 greater than T greater than 0.3 K. In pure 4 He below about 0.7 K, several new effects not seen at higher temperatures are observed and are not easily explained with existing theories. Most notable are an enhanced broadening of the ion pulse and a rapid increase in the mobility with decreasing temperature. Measurements of the electric field dependence of the drift velocity in pure 4 He at low temperatures show a limiting velocity for sufficiently large fields. This behavior can be explained using a simple resonance theory. The inverse mobility data for solutions show sharp increases at certain critical temperatures, which are interpreted as being associated with the condensation of 3 He atoms onto the vortex cores. The dependence of the critical temperature on the bulk 3 He concentration is found to be in good agreement with a simple condensation theory. An extension of arguments used in this theory to lower temperatures leads to the picture of a 3 He-rich core growing with decreasing temperature, consistent with our lower temperature experimental data

  11. Determination of electron impact ionization and excitation coefficients in He-Xe gas mixtures. He-Xe kongo gas ni okeru denshi shototsu denri keisu oyobi reiki keisu no sokutei to kaiseki

    Energy Technology Data Exchange (ETDEWEB)

    Takahashi, K.; Tachibana, K. (Kyoto Inst. of Technology, Kyoto (Japan))

    1991-03-20

    The rare gas discharge gives a stable discharge and light emission characteristics at low temperature in comparison with the discharge of the vapor of such a metal as Hg. The present barrier for the commercialization of the color PDP lies in the lower level of its emission intensity and efficiency in comparison with that of CRT. In this report, an electron impact ionization coefficient in a gas mixture and an electron impact excitation coefficient for a XeIs {sub 4} level were analyzed using a Boltzmann equation by means of a steady state Townsend method using a drift tube. By comparing both, the elementary process in the gas mixture is investiagted to discuss the respective contributions for the effective ionization coefficient and the excitation coefficient. As a result, it was found that the ionization process in the He-Xe gas mixture could be described by the processes of direct ionization of Xe and He, and an indirect ionization (Penning effect) by an active helium. 37 refs., 12 figs.

  12. Atmospheric chemistry of (Z)-CF3CH═CHCF3: OH radical reaction rate coefficient and global warming potential.

    Science.gov (United States)

    Baasandorj, Munkhbayar; Ravishankara, A R; Burkholder, James B

    2011-09-29

    Rate coefficients, k, for the gas-phase reaction of the OH radical with (Z)-CF(3)CH═CHCF(3) (cis-1,1,1,4,4,4-hexafluoro-2-butene) were measured under pseudo-first-order conditions in OH using pulsed laser photolysis (PLP) to produce OH and laser-induced fluorescence (LIF) to detect it. Rate coefficients were measured over a range of temperatures (212-374 K) and bath gas pressures (20-200 Torr; He, N(2)) and found to be independent of pressure over this range of conditions. The rate coefficient has a non-Arrhenius behavior that is well-described by the expression k(1)(T) = (5.73 ± 0.60) × 10(-19) × T(2) × exp[(678 ± 10)/T] cm(3) molecule(-1) s(-1) where k(1)(296 K) was measured to be (4.91 ± 0.50) × 10(-13) cm(3) molecule(-1) s(-1) and the uncertainties are at the 2σ level and include estimated systematic errors. Rate coefficients for the analogous OD radical reaction were determined over a range of temperatures (262-374 K) at 100 Torr (He) to be k(2)(T) = (4.81 ± 0.20) × 10(-19) × T(2) × exp[(776 ± 15)/T], with k(2)(296 K) = (5.73 ± 0.50) × 10(-13) cm(3) molecule(-1) s(-1). OH radical rate coefficients were also measured at 296, 345, and 375 K using a relative rate technique and found to be in good agreement with the PLP-LIF results. A room-temperature rate coefficient for the O(3) + (Z)-CF(3)CH═CHCF(3) reaction was measured using an absolute method with O(3) in excess to be reaction was estimated to be ~20 days. Infrared absorption spectra of (Z)-CF(3)CH═CHCF(3) measured in this work were used to determine a (Z)-CF(3)CH═CHCF(3) global warming potential (GWP) of ~9 for the 100 year time horizon. A comparison of the OH reactivity of (Z)-CF(3)CH═CHCF(3) with other unsaturated fluorinated compounds is presented.

  13. Effective interactions in dilute mixtures of 3He in 4He

    International Nuclear Information System (INIS)

    Hsu, W.; Pines, D.

    1985-01-01

    Nonlocal pseudopotentials which describe the effective interaction between 3 He quasiparticles, and between these quasiparticles and the background 4 He liquid, are obtained as a function of concentration and pressure by generalizing the Aldrich--Pines pseudopotentials for pure 3 He and 4 He to dilute mixtures. The hierarchy of physical effects which determine these pseudopotentials is established. Interaction-induced short-range correlations are the dominant physical feature; next in order of importance is the greater zero point motion associated with the replacement of a 4 He atom by a 3 He atom, while spin-duced ''Pauli principle'' correlations play a significantly smaller, albeit still important role. We find a consistent trend in the change of the effective direct quasiparticle interactions with increasing concentration, and show how the Aldrich-Pines pseudopotentials for pure 3 He quasiparticles represent a natural extension of our results for dilute mixtures. Our calculated nonlocal pseudopotential for 3 He quasiparticles is qualitatively similar to that proposed by Bardeen, Baym, and Pines; it changes sign at somewhat lower momentum transfers than the BBP result, varies little with concentration, and provides a physical basis for understanding the BBP result. The effective interaction between quasiparticles of parallel spin, here determined for the first time, is essentially repulsive in the very dilute limit; as the concentration increases, it becomes increasingly attractive at low momentum transfers, and resembles closely that between antiparallel spin quasiparticles at 5% concentration. The concentration-dependent transport properties calculated from these pseudopotentials (which involve only one phenomenological parameter) are in good agreement with experiment at saturated vapor pressure (SVP), 10 atm, and 20 atm

  14. The Gini coefficient: a methodological pilot study to assess fetal brain development employing postmortem diffusion MRI

    Energy Technology Data Exchange (ETDEWEB)

    Viehweger, Adrian; Sorge, Ina; Hirsch, Wolfgang [University Hospital Leipzig, Department of Pediatric Radiology, Leipzig (Germany); Riffert, Till; Dhital, Bibek; Knoesche, Thomas R.; Anwander, Alfred [Max Planck Institute for Human Cognitive and Brain Sciences, Leipzig (Germany); Stepan, Holger [University Leipzig, Department of Obstetrics, Leipzig (Germany)

    2014-10-15

    Diffusion-weighted imaging (DWI) is important in the assessment of fetal brain development. However, it is clinically challenging and time-consuming to prepare neuromorphological examinations to assess real brain age and to detect abnormalities. To demonstrate that the Gini coefficient can be a simple, intuitive parameter for modelling fetal brain development. Postmortem fetal specimens(n = 28) were evaluated by diffusion-weighted imaging (DWI) on a 3-T MRI scanner using 60 directions, 0.7-mm isotropic voxels and b-values of 0, 150, 1,600 s/mm{sup 2}. Constrained spherical deconvolution (CSD) was used as the local diffusion model. Fractional anisotropy (FA), apparent diffusion coefficient (ADC) and complexity (CX) maps were generated. CX was defined as a novel diffusion metric. On the basis of those three parameters, the Gini coefficient was calculated. Study of fetal brain development in postmortem specimens was feasible using DWI. The Gini coefficient could be calculated for the combination of the three diffusion parameters. This multidimensional Gini coefficient correlated well with age (Adjusted R{sup 2} = 0.59) between the ages of 17 and 26 gestational weeks. We propose a new method that uses an economics concept, the Gini coefficient, to describe the whole brain with one simple and intuitive measure, which can be used to assess the brain's developmental state. (orig.)

  15. Fast-GPU-PCC: A GPU-Based Technique to Compute Pairwise Pearson's Correlation Coefficients for Time Series Data-fMRI Study.

    Science.gov (United States)

    Eslami, Taban; Saeed, Fahad

    2018-04-20

    Functional magnetic resonance imaging (fMRI) is a non-invasive brain imaging technique, which has been regularly used for studying brain’s functional activities in the past few years. A very well-used measure for capturing functional associations in brain is Pearson’s correlation coefficient. Pearson’s correlation is widely used for constructing functional network and studying dynamic functional connectivity of the brain. These are useful measures for understanding the effects of brain disorders on connectivities among brain regions. The fMRI scanners produce huge number of voxels and using traditional central processing unit (CPU)-based techniques for computing pairwise correlations is very time consuming especially when large number of subjects are being studied. In this paper, we propose a graphics processing unit (GPU)-based algorithm called Fast-GPU-PCC for computing pairwise Pearson’s correlation coefficient. Based on the symmetric property of Pearson’s correlation, this approach returns N ( N − 1 ) / 2 correlation coefficients located at strictly upper triangle part of the correlation matrix. Storing correlations in a one-dimensional array with the order as proposed in this paper is useful for further usage. Our experiments on real and synthetic fMRI data for different number of voxels and varying length of time series show that the proposed approach outperformed state of the art GPU-based techniques as well as the sequential CPU-based versions. We show that Fast-GPU-PCC runs 62 times faster than CPU-based version and about 2 to 3 times faster than two other state of the art GPU-based methods.

  16. Atomic interaction with quantum fluid clusters: cross-jet deflection of 3He- and 4He-clusters

    International Nuclear Information System (INIS)

    Gspann, J.; Vollmar, H.

    1977-01-01

    The authors have studied earlier the velocity dependence of the total scattering of Cs atomic beams by 4 He-cluster beams, in comparison with corresponding experiments with N 2 - and Ne-cluster beams. Only with the 4 He-cluster beams a deficiency in the effective total scattering compared to the expected behaviour has been observed which was largest near 200 m/s of relative velocity. However, it is difficult to estimate, and therefore still a matter of investigation, to which extent this effect could be attributed to the presence of a small amount of uncondensed helium atoms in the cluster beam. In this paper a first account is given on an experimental study of the drag coefficients in free molecular flow of helium clusters of either isotope. The drag coefficients describe the respective efficiencies of linear momentum transfer onto the clusters and are found to be appreciably lower for helium than for nitrogen clusters which is ascribed to the fluidity of the helium clusters. (Auth.)

  17. Computerized liver volumetry on MRI by using 3D geodesic active contour segmentation.

    Science.gov (United States)

    Huynh, Hieu Trung; Karademir, Ibrahim; Oto, Aytekin; Suzuki, Kenji

    2014-01-01

    Our purpose was to develop an accurate automated 3D liver segmentation scheme for measuring liver volumes on MRI. Our scheme for MRI liver volumetry consisted of three main stages. First, the preprocessing stage was applied to T1-weighted MRI of the liver in the portal venous phase to reduce noise and produce the boundary-enhanced image. This boundary-enhanced image was used as a speed function for a 3D fast-marching algorithm to generate an initial surface that roughly approximated the shape of the liver. A 3D geodesic-active-contour segmentation algorithm refined the initial surface to precisely determine the liver boundaries. The liver volumes determined by our scheme were compared with those manually traced by a radiologist, used as the reference standard. The two volumetric methods reached excellent agreement (intraclass correlation coefficient, 0.98) without statistical significance (p = 0.42). The average (± SD) accuracy was 99.4% ± 0.14%, and the average Dice overlap coefficient was 93.6% ± 1.7%. The mean processing time for our automated scheme was 1.03 ± 0.13 minutes, whereas that for manual volumetry was 24.0 ± 4.4 minutes (p volumetry based on our automated scheme agreed excellently with reference-standard volumetry, and it required substantially less completion time.

  18. Coupling between Solid 3He on Aerogel and Superfluid 3He in the Low Temperature Limit

    International Nuclear Information System (INIS)

    Bradley, D. I.; Fisher, S. N.; Guenault, A. M.; Haley, R. P.; Pickett, G. R.; Tsepelin, V.; Whitehead, R. C. V.; Skyba, P.

    2006-01-01

    We have cooled liquid 3He contained in a 98% open aerogel sample surrounded by bulk superfluid 3He-B at zero pressure to below 120 μK. The aerogel sample is placed in a quasiparticle blackbody radiator cooled by a Lancaster-style nuclear cooling stage to ∼200 μK. We monitor the temperature of the 3He inside the blackbody radiator using a vibrating wire resonator. We find that reducing the magnetic field on the aerogel sample causes substantial cooling of all the superfluid inside the blackbody radiator. We believe this is due to the demagnetization of the solid 3He layers on the aerogel strands. This system has potential for achieving extremely low temperatures in the confined fluid

  19. Effects of Δ-isobar degrees of freedom on the reactions 3He(n,γ)4He and 3He(p,e+νe)4He at low-energy

    International Nuclear Information System (INIS)

    Schiavilla, R.

    1991-01-01

    The cross sections of the radiative 3 He(n,γ) 4 He and weak 3 He(p,e + ν e ) 4 He capture reactions at thermal neutron and keV proton energies have been calculated with the Variational Monte Carlo method. The ground state and low-energy continuum wave functions have been determined variationally from a realistic Hamiltonian, and include both nucleon and Δ-isobar degrees of freedom. The electroweak transition operator contains one- and two-body components in the N + Δ Hilbert space

  20. Hyperpolarized 89Y NMR spectroscopic detection of yttrium ion and DOTA macrocyclic ligand complexation: pH dependence and Y-DOTA intermediates

    Science.gov (United States)

    Ferguson, Sarah; Kiswandhi, Andhika; Niedbalski, Peter; Parish, Christopher; Kovacs, Zoltan; Lumata, Lloyd

    Dissolution dynamic nuclear polarization (DNP) is a rapidly emerging physics technique used to enhance the signal strength in nuclear magnetic resonance (NMR) and imaging (MRI) experiments for nuclear spins such as yttrium-89 by >10,000-fold. One of the most common and stable MRI contrast agents used in the clinic is Gd-DOTA. In this work, we have investigated the binding of the yttrium and DOTA ligand as a model for complexation of Gd ion and DOTA ligand. The macrocyclic ligand DOTA is special because its complexation with lanthanide ions such as Gd3+ or Y3+ is highly pH dependent. Using this physics technology, we have tracked the complexation kinetics of hyperpolarized Y-triflate and DOTA ligand in real-time and detected the Y-DOTA intermediates. Different kinds of buffers were used (lactate, acetate, citrate, oxalate) and the pseudo-first order complexation kinetic calculations will be discussed. The authors would like to acknowledge the support by US Dept of Defense Award No. W81XWH-14-1-0048 and Robert A. Welch Foundation Grant No. AT-1877.

  1. Recombination of H{sup +}{sub 3} ions in the afterglow of a He-Ar-H{sub 2} plasma

    Energy Technology Data Exchange (ETDEWEB)

    Glosik, J; Korolov, I; Plasil, R; Novotny, O; Kotrik, T; Hlavenka, P; Varju, J [Mathematics and Physics Faculty, Charles University in Prague, Prague 8 (Czech Republic); Mikhailov, I A; Kokoouline, V [Department of Physics, University of Central Florida, Orlando, FL 32816 (United States); Greene, Chris H [Department of Physics and JILA, University of Colorado, Boulder, CO 80309-0440 (United States)], E-mail: Juraj.Glosik@mff.cuni.cz

    2008-10-14

    Recombination of H{sup +}{sub 3} with electrons is studied in a low-temperature plasma containing He, H{sub 2} and Ar at different He and H{sub 2} densities. The effective plasma recombination rate is driven by binary, H{sup +}{sub 3} + e{sup -}, and ternary, H{sup +}{sub 3} + e{sup -}+ He, processes with the rate coefficients 7.5 x 10{sup -8} cm{sup 3} s{sup -1} and 2.8 x 10{sup -25} cm{sup 6} s{sup -1} respectively at 260 K. We suggest that the ternary recombination involves formation of neutral highly excited Rydberg H{sub 3} followed by an l-changing collision with He. The difference between recombination of para- and ortho-H{sup +}{sub 3} is discussed. (fast track communication)

  2. Single-Shot-RARE for rapid 3D hyperpolarized metabolic ex vivo tissue imaging: RF-pulse design for semi-dense spectra

    DEFF Research Database (Denmark)

    Magnusson, P.O.; Jensen, Pernille Rose; Dyrby, Tim Bjørn

    MRS of hyperpolarized (HP) 13C-enriched compounds is a promising method for in vivo cancer diagnosis . Sentinel lymph node ex vivo tissue sample histology used in clinical routine for breast cancer metastasis diagnosis requires time consuming sample analysis. 3D-HP-MRSI can potentially speed up...

  3. Low energy electron capture in collisions of C3+ with He

    International Nuclear Information System (INIS)

    Wu, Y.; Qi, Y.Y.; Yan, J.; Wang, J.G.; Li, Y.; Buenker, R.J.; Kato, D.

    2009-06-01

    Charge transfer processes due to collisions of ground state C 3+ (1s 2 2s 2 S) ions with He atom are investigated using the quantum-mechanical molecular-orbital close-coupling (QMOCC) method for energies between 10 -4 eV/u and 10 3 eV/u. The ab initio adiabatic potential and radial coupling utilized in the QMOCC calculations are obtained from the multi-reference single- and double-excitation configuration interaction (MRD-CI) approach. Total and state-selective single electron capture (SEC) cross sections and rate coefficients are obtained and compared with the available experimental and theoretical data. Good agreement between the measured SEC cross sections and the present calculation is found, but the previous calculation of total rate coefficient using the Landau-Zener model is one or two orders of magnitude smaller than the present result. (author)

  4. Quantitative 3D ultrashort time-to-echo (UTE) MRI and micro-CT (μCT) evaluation of the temporomandibular joint (TMJ) condylar morphology

    Energy Technology Data Exchange (ETDEWEB)

    Geiger, Daniel [Sapienza University of Rome, Department of Radiological, Oncological and Pathological Sciences, Rome (Italy); Bae, Won C.; Statum, Sheronda; Du, Jiang; Chung, Christine B. [University of California-San Diego, Department of Radiology, San Diego, CA (United States)

    2014-01-15

    Temporomandibular dysfunction involves osteoarthritis of the TMJ, including degeneration and morphologic changes of the mandibular condyle. The purpose of this study was to determine the accuracy of novel 3D-UTE MRI versus micro-CT (μCT) for quantitative evaluation of mandibular condyle morphology. Nine TMJ condyle specimens were harvested from cadavers (2 M, 3 F; age 85 ± 10 years, mean ± SD). 3D-UTE MRI (TR = 50 ms, TE = 0.05 ms, 104-μm isotropic-voxel) was performed using a 3-T MR scanner and μCT (18-μm isotropic-voxel) was also performed. MR datasets were spatially registered with a μCT dataset. Two observers segmented bony contours of the condyles. Fibrocartilage was segmented on the MR dataset. Using a custom program, bone and fibrocartilage surface coordinates, Gaussian curvature, volume of segmented regions, and fibrocartilage thickness were determined for quantitative evaluation of joint morphology. Agreement between techniques (MRI vs. μCT) and observers (MRI vs. MRI) for Gaussian curvature, mean curvature, and segmented volume of the bone were determined using intraclass correlation coefficient (ICC) analysis. Between MRI and μCT, the average deviation of surface coordinates was 0.19 ± 0.15 mm, slightly higher than the spatial resolution of MRI. Average deviation of the Gaussian curvature and volume of segmented regions, from MRI to μCT, was 5.7 ± 6.5 % and 6.6 ± 6.2 %, respectively. ICC coefficients (MRI vs. μCT) for Gaussian curvature, mean curvature, and segmented volumes were 0.892, 0.893, and 0.972, respectively. Between observers (MRI vs. MRI), the ICC coefficients were 0.998, 0.999, and 0.997, respectively. Fibrocartilage thickness was 0.55 ± 0.11 mm, as previously described in the literature for grossly normal TMJ samples. 3D-UTE MR quantitative evaluation of TMJ condyle morphology ex-vivo, including surface, curvature, and segmented volume, shows high correlation against μCT and between observers. In addition, UTE MRI allows

  5. Giant asymmetry of separation and homogenization processes in solid 3He-4He solutions

    International Nuclear Information System (INIS)

    Grigor'ev, V.N.; Majdanov, V.A.; Penzev, A.A.; Polev, A.V.; Rubets, S.P.; Rudavskij, Eh.Ya.; Rybalko, A.S.; Syrnikov, E.V.

    2005-01-01

    The kinetics of the processes of separation and homogenization of solid 3 He- 4 He solutions is compared by using the precision barometry. The experiments were made with the initial specimens of three types: weak 3 He- 4 He and 4 He- 3 He solutions and concentrated 3 He- 4 He ones. It is found that the homogenization rate at the initial stage may be more than 500 times higher that the rate of separation. This is the case for all types of the solutions studied. The appreciable rate of phase separation in the concentrated solutions where, according to the modern concepts, impurity atoms in quantum crystals should be localized, suggests that in such conditions there is a new unknown mechanism of mass-transfer, while the fast homogenization points to a nondiffusion nature of the process

  6. Diffusion of He interstitial and di-He cluster at grain boundaries in α-Fe

    International Nuclear Information System (INIS)

    Gao, F.; Heinisch, H.L.; Kurtz, R.J.

    2007-01-01

    A systematic molecular dynamics study of the diffusion mechanisms of He interstitial and di-He cluster at two representative interfaces has been carried out in α-Fe. The diffusion coefficient of a He interstitial and the effective migration energies were determined. The He atom diffuses along the Σ11 grain boundary one-dimensionally along specific directions, while it migrates two-dimensionally at low temperatures, and three-dimensionally at higher temperatures, in the Σ3 grain boundary. The di-He interstitial cluster can migrate rapidly along the Σ3 interface at low temperatures, but not at the Σ11 interface. It has been observed that a di-He interstitial cluster can kick out a self interstitial atom (SIA) at high temperatures, forming a He 2 V complex. The SIA migrates rapidly near interfaces, whereas the He 2 V complex is immobile at the temperatures considered. This small cluster may serve as the smallest nucleation for the formation of helium bubbles at interfaces

  7. Overlap integrals of model wave functions of 4He and 3He,3H nuclei

    International Nuclear Information System (INIS)

    Voloshin, N.I.; Levshin, E.B.; Fursa, A.D.

    1990-01-01

    Overlap integrals of wave functions 4 He nucleus and 3 He and 3 H nuclei are calculated. Two types of model wave functions are used to describe the structure of nuclei. The wace function is taken as a product of the one-particle Gaussian functions of the Gaussian type in the second case

  8. Hyperpolarized singlet NMR on a small animal imaging system

    DEFF Research Database (Denmark)

    Laustsen, Christoffer; Pileio, Giuseppe; Tayler, Michael C. D.

    2012-01-01

    Nuclear spin hyperpolarization makes a significant advance toward overcoming the sensitivity limitations of in vivo magnetic resonance imaging, particularly in the case of low-gamma nuclei. The sensitivity may be improved further by storing the hyperpolarization in slowly relaxing singlet...... populations of spin- 1/2 pairs. Here, we report hyperpolarized 13C spin order transferred into and retrieved from singlet spin order using a small animal magnetic resonance imaging scanner. For spins in sites with very similar chemical shifts, singlet spin order is sustained in high magnetic field without...... requiring strong radiofrequency irradiation. The demonstration of robust singlet-to-magnetization conversion, and vice versa, on a small animal scanner, is promising for future in vivo and clinical deployments....

  9. Hyperpolarized [1-13C]Pyruvate MRI identifies metabolic differences pertaining to the fasted and fed state in porcine cardiac metabolism

    DEFF Research Database (Denmark)

    Tougaard, Rasmus Stilling; Søvsø Szocska Hansen, Esben; Laustsen, Christoffer

    Standardized large animal models for cardiac hyperpolarized MR metabolic studies are becoming increasingly important as translation into human trials progresses. We employed a porcine (n=17) model of fasting/feeding to study these two states and to examine normal feeding as a standardized model f...

  10. Determination of the π3He3H coupling constant

    International Nuclear Information System (INIS)

    Nichitiu, F.; Sapozhnikov, M.G.

    1977-01-01

    Despersion relations for the real part of the antisymmetric amplitude of the π +-3 He scattering have been used in order to determine the π 3 He 3 H coupling constant. The coupling constant value determined by this method is larger than the elementary pion-nucleon coupling constant, but is in good agreement with the value obtained by another method. The obtained value is f 2 sub(π 3 He 3 H) = 0.12+-0.01. Shown is the importance of using the Coulomb corrections for dispersion relation calculations because the value of π 3 He 3 H coupling constant obtained with corrected total cross sections is larger by about 0.014 than the one obtained without these corrections. The best energy ranges for future π 3 He experiments are commented

  11. Predicting and monitoring response to chemotherapy by 1,3-bis(2-chloroethyl)-1-nitrosourea in subcutaneously implanted 9L glioma using the apparent diffusion coefficient of water and 23Na MRI.

    Science.gov (United States)

    Babsky, Andriy M; Hekmatyar, S K; Zhang, Hong; Solomon, James L; Bansal, Navin

    2006-07-01

    To examine the effects of the alkylating anticancer drug 1,3-bis(2-chloroethyl)-1-nitrosourea (BCNU) on (23)Na MRI and the water apparent diffusion coefficient (ADC) in subcutaneously- (sc-) implanted 9L glioma in rats. (23)Na MRI and (1)H water ADC measurements were performed on sham-treated control (N = 6) and BCNU-treated (N = 15) Fisher rats one day before BCNU injection and then one, three, and five days after BCNU injection. The BCNU-treated tumors were divided into BCNU-responsive (R(BCNU)) and BCNU-nonresponsive (NR(BCNU)) groups depending on the tumor volume changes that occurred after therapy. The pretreatment (23)Na MRI signal intensity (SI) and water ADC values were higher in R(BCNU) tumors compared to NR(BCNU) tumors. (23)Na MRI SI and water ADC increased with tumor growth in control and NR(BCNU) groups, but these changes were interrupted by BCNU therapy in R(BCNU) group. (23)Na MRI and water ADC measurements may be useful for predicting and monitoring response to chemotherapy in some tumors. However, the changes that occurred in (23)Na MRI SI and water ADC in sc-implanted 9L tumors are in contrast to previously published results for BCNU therapy of orthotopic 9L tumors. This may have important implications for monitoring therapy response in tumors. (c) 2006 Wiley-Liss, Inc.

  12. 3D Super-Resolution Motion-Corrected MRI: Validation of Fetal Posterior Fossa Measurements.

    Science.gov (United States)

    Pier, Danielle B; Gholipour, Ali; Afacan, Onur; Velasco-Annis, Clemente; Clancy, Sean; Kapur, Kush; Estroff, Judy A; Warfield, Simon K

    2016-09-01

    Current diagnosis of fetal posterior fossa anomalies by sonography and conventional MRI is limited by fetal position, motion, and by two-dimensional (2D), rather than three-dimensional (3D), representation. In this study, we aimed to validate the use of a novel magnetic resonance imaging (MRI) technique, 3D super-resolution motion-corrected MRI, to image the fetal posterior fossa. From a database of pregnant women who received fetal MRIs at our institution, images of 49 normal fetal brains were reconstructed. Six measurements of the cerebellum, vermis, and pons were obtained for all cases on 2D conventional and 3D reconstructed MRI, and the agreement between the two methods was determined using concordance correlation coefficients. Concordance of axial and coronal measurements of the transcerebellar diameter was also assessed within each method. Between the two methods, the concordance of measurements was high for all six structures (P fetal motion and orthogonal slice acquisition. This technique will facilitate further study of fetal abnormalities of the posterior fossa. Copyright © 2016 by the American Society of Neuroimaging.

  13. Phase equilibrium in a polarized saturated 3He-4He mixture

    International Nuclear Information System (INIS)

    Rodrigues, A.; Vermeulen, G.

    1997-01-01

    We present experimental results on the phase equilibrium of a saturated 3 He- 4 He mixture, which has been cooled to a temperature of 10-15 mK and polarized in a 4 He circulating dilution refrigerator to a stationary polarization of 15 %, 7 times higher than the equilibrium polarization in the external field of 7 T. The pressure dependence of the polarization enhancement in the refrigerator shows that the molar susceptibilities of the concentrated and dilute phase of a saturated 3 He- 4 He mixture are equal at p = 2.60 ± 0.04 bar. This result affects the Fermi liquid parameters of the dilute phase. The osmotic pressure in the dilute phase has been measured as a function of the polarization of the coexisting concentrated phase up to 15 %. We find that the osmotic pressure at low polarization ( < 7 % ) agrees well with thermodynamics using the new Fermi liquid parameters of the dilute phase

  14. Hyperpolarized metabolic MR in the study of cardiac function and disease

    DEFF Research Database (Denmark)

    Lauritzen, M. H.; Søgaard, L. V.; Madsen, Pia Lisbeth

    2014-01-01

    Several diseases of the heart have been linked to an insufficient ability to generate enough energy (ATP) to sustain proper heart function. Hyperpolarized magnetic resonance (MR) is a novel technique that can visualize and quantify myocardial energy metabolism. Hyperpolarization enhances the MR...... signal from a biological molecule of interest by more than 10,000 times, making it possible to measure its cellular uptake and conversion in specific enzymatic pathways in real time. We review the role of hyperpolarized MR in identifying changes in cardiac metabolism in vivo, and present the extensive...... literature on hyperpolarized pyruvate that has been used to characterize cardiac disease in various in vivo models, such as myocardial ischemia, hypertension, diabetes, hyperthyroidism and heart failure. The technical aspects of the technique are presented as well as the challenges of translating...

  15. Long-range interactions of excited He atoms with ground-state noble-gas atoms

    KAUST Repository

    Zhang, J.-Y.

    2013-10-09

    The dispersion coefficients C6, C8, and C10 for long-range interactions of He(n1,3S) and He(n1,3P), 2≤n≤10, with the ground-state noble-gas atoms Ne, Ar, Kr, and Xe are calculated by summing over the reduced matrix elements of multipole transition operators. The large-n expansions for the sums over the He oscillator strength divided by the corresponding transition energy are presented for these series. Using the expansions, the C6 coefficients for the systems involving He(131,3S) and He(131,3P) are calculated and found to be in good agreement with directly calculated values.

  16. Structure properties of the 3He-4He mixture at T = O K

    International Nuclear Information System (INIS)

    Boronat, J.; Polls, A.; Fabrocini, A.

    1993-01-01

    The spatial structure properties of 3 He- 4 He mixtures at T = O K are investigated using the hypernetted-chain formalism. The variational wave function used to describe the ground-state of the mixture is a simple generalization of the trial wave functions for pure phases and contains two- and three-body correlations. The elementary diagrams are taken into account by means of an extension of the scaling approximation to the mixtures. The two-body distribution (g (α,β) (r)) and the structure functions (S (α,β) (k)) together with the different spin-spin distribution functions for the 3 He component in the mixture are analyzed for several concentrations of 3 He. Two sum-rules, for the direct and the exchange part of the g (3,3) (r), are used to ascertain the importance of the full treatment of the Fermi statistics in the calculation. The statistical correlations are found responsible for the main differences between the several components of the distribution function. Due to its low concentration, 3 He behaves as a quasi-free Fermi gas, as far as the statistical correlations are concerned, although it is strongly correlated with the 4 He atoms through the interatomic potential

  17. On friction of Nb-Nb pair in He1 and He2

    International Nuclear Information System (INIS)

    Zinenko, S.A.; Karapetyan, S.S.; Silin, A.A.

    1990-01-01

    Peculiarities of manifestation of the effect of anomalous friction of superconductors (AFS) in He1 and He2 are studied. Helium thermodynamic state effect on the character of friction interaction of Nb-Nb pair velocity and reduction ratio for friction coefficient is studied. The intensity of heat removal released from friction contact region is estimated, the necessary and sufficient conditions for AFC effect manifestation are ascertained using characteristic relaxation time concept. Dependences for Nb-Nb pair friction coefficient in a superconducting state on the time of friction interaction in gaseous helium, He1, He2 are presented

  18. Quantification of regional early stage gas exchange changes using hyperpolarized {sup 129}Xe MRI in a rat model of radiation-induced lung injury

    Energy Technology Data Exchange (ETDEWEB)

    Doganay, Ozkan, E-mail: ozkan.doganay@oncology.ox.ac.uk [Department of Medical Biophysics, Western University, London, Ontario N6A5C1 (Canada); Imaging Research Laboratories, Robarts Research Institute, London, Ontario N6A5C1 (Canada); Department of Oncology, University of Oxford, Old Road Campus Research Building, Roosevelt Drive, Oxford OX3 7DQ (United Kingdom); Stirrat, Elaine [Peter Gilgan Centre for Research and Learning, The Hospital for Sick Children, 555 University Avenue, Toronto, Ontario M5G1X8 (Canada); McKenzie, Charles [Department of Medical Biophysics, Western University, London, Ontario N6A5C1 (Canada); Imaging Research Laboratories, Robarts Research Institute, London, Ontario N6A5C1 (Canada); Schulte, Rolf F. [General Electric Global Research, Munich 85748 (Germany); Santyr, Giles E. [Department of Medical Biophysics, Western University, London, Ontario N6A5C1 (Canada); Imaging Research Laboratories, Robarts Research Institute, London, Ontario N6A5C1 (Canada); Peter Gilgan Centre for Research and Learning, The Hospital for Sick Children, 555 University Avenue, Toronto, Ontario M5G1X8 (Canada); Department of Medical Biophysics, University of Toronto, Toronto, Ontario M5G1L7 (Canada)

    2016-05-15

    Purpose: To assess the feasibility of hyperpolarized (HP) {sup 129}Xe MRI for detection of early stage radiation-induced lung injury (RILI) in a rat model involving unilateral irradiation by assessing differences in gas exchange dynamics between irradiated and unirradiated lungs. Methods: The dynamics of gas exchange between alveolar air space and pulmonary tissue (PT), PT and red blood cells (RBCs) was measured using single-shot spiral iterative decomposition of water and fat with echo asymmetry and least-squares estimation images of the right and left lungs of two age-matched cohorts of Sprague Dawley rats. The first cohort (n = 5) received 18 Gy irradiation to the right lung using a {sup 60}Co source and the second cohort (n = 5) was not irradiated and served as the healthy control. Both groups were imaged two weeks following irradiation when radiation pneumonitis (RP) was expected to be present. The gas exchange data were fit to a theoretical gas exchange model to extract measurements of pulmonary tissue thickness (L{sub PT}) and relative blood volume (V{sub RBC}) from each of the right and left lungs of both cohorts. Following imaging, lung specimens were retrieved and percent tissue area (PTA) was assessed histologically to confirm RP and correlate with MRI measurements. Results: Statistically significant differences in L{sub PT} and V{sub RBC} were observed between the irradiated and non-irradiated cohorts. In particular, L{sub PT} of the right and left lungs was increased approximately 8.2% and 5.0% respectively in the irradiated cohort. Additionally, V{sub RBC} of the right and left lungs was decreased approximately 36.1% and 11.7% respectively for the irradiated cohort compared to the non-irradiated cohort. PTA measurements in both right and left lungs were increased in the irradiated group compared to the non-irradiated cohort for both the left (P < 0.05) and right lungs (P < 0.01) confirming the presence of RP. PTA measurements also correlated with the

  19. Experimental considerations on producing highly polarized liquid 3He in a matrix of solid 4He

    International Nuclear Information System (INIS)

    Greenberg, A.S.; Hebral, B.; Papoular, M.; Beal-Monod, M.T.

    1980-01-01

    Two experiments are briefly reviewed in which droplets of 3 He were formed in solid 4 He. These experiments indicate such conditions are favorable for the production of quasi-stable highly polarized liquid 3 He. A solid solution of dilute 3 He in 4 He is proposed as a promising system to produce experimentally realizable highly polarized liquid 3 He using the Castaing-Nozieres decompression

  20. Anomalous Quasiparticle Reflection from the Surface of a ^{3}He-^{4}He Dilute Solution.

    Science.gov (United States)

    Ikegami, Hiroki; Kim, Kitak; Sato, Daisuke; Kono, Kimitoshi; Choi, Hyoungsoon; Monarkha, Yuriy P

    2017-11-10

    A free surface of a dilute ^{3}He-^{4}He liquid mixture is a unique system where two Fermi liquids with distinct dimensions coexist: a three-dimensional (3D) ^{3}He Fermi liquid in the bulk and a two-dimensional (2D) ^{3}He Fermi liquid at the surface. To investigate a novel effect generated by the interaction between the two Fermi liquids, the mobility of a Wigner crystal of electrons formed on the free surface of the mixture is studied. An anomalous enhancement of the mobility, compared with the case where the 3D and 2D systems do not interact with each other, is observed. The enhancement is explained by the nontrivial reflection of 3D quasiparticles from the surface covered with the 2D ^{3}He system.

  1. WE-AB-202-12: Voxel-Wise Analysis of Apparent Diffusion Coefficient and Perfusion Maps in Multi-Parametric MRI of Prostate Cancer

    International Nuclear Information System (INIS)

    Engstroem, K; Casares-Magaz, O; Muren, L; Roervik, J; Andersen, E

    2016-01-01

    Purpose: Multi-parametric MRI (mp-MRI) is being introduced in radiotherapy (RT) of prostate cancer, including for tumour delineation in focal boosting strategies. We recently developed an image-based tumour control probability model, based on cell density distributions derived from apparent diffusion coefficient (ADC) maps. Beyond tumour volume and cell densities, tumour hypoxia is also an important determinant of RT response. Since tissue perfusion from mp-MRI has been related to hypoxia we have explored the patterns of ADC and perfusion maps, and the relations between them, inside and outside prostate index lesions. Methods: ADC and perfusion maps from 20 prostate cancer patients were used, with the prostate and index lesion delineated by a dedicated uro-radiologist. To reduce noise, the maps were averaged over a 3×3×3 voxel cube. Associations between different ADC and perfusion histogram parameters within the prostate, inside and outside the index lesion, were evaluated with the Pearson’s correlation coefficient. In the voxel-wise analysis, scatter plots of ADC vs perfusion were analysed for voxels in the prostate, inside and outside of the index lesion, again with the associations quantified with the Pearson’s correlation coefficient. Results: Overall ADC was lower inside the index lesion than in the normal prostate as opposed to ktrans that was higher inside the index lesion than outside. In the histogram analysis, the minimum ktrans was significantly correlated with the maximum ADC (Pearson=0.47; p=0.03). At the voxel level, 15 of the 20 cases had a statistically significant inverse correlation between ADC and perfusion inside the index lesion; ten of the cases had a Pearson < −0.4. Conclusion: The minimum value of ktrans across the tumour was correlated to the maximum ADC. However, on the voxel level, the ‘local’ ktrans in the index lesion is inversely (i.e. negatively) correlated to the ‘local’ ADC in most patients. Research agreement with

  2. 3He Abundances in Planetary Nebulae

    Science.gov (United States)

    Guzman-Ramirez, Lizette

    2017-10-01

    Determination of the 3He isotope is important to many fields of astrophysics, including stellar evolution, chemical evolution, and cosmology. The isotope is produced in stars which evolve through the planetary nebula phase. Planetary nebulae are the final evolutionary phase of low- and intermediate-mass stars, where the extensive mass lost by the star on the asymptotic giant branch is ionised by the emerging white dwarf. This ejecta quickly disperses and merges with the surrounding ISM. 3He abundances in planetary nebulae have been derived from the hyperfine transition of the ionised 3He, 3He+, at the radio rest frequency 8.665 GHz. 3He abundances in PNe can help test models of the chemical evolution of the Galaxy. Many hours have been put into trying to detect this line, using telescopes like the Effelsberg 100m dish of the Max Planck Institute for Radio Astronomy, the National Radio Astronomy Observatory (NRAO) 140-foot telescope, the NRAO Very Large Array, the Arecibo antenna, the Green Bank Telescope, and only just recently, the Deep Space Station 63 antenna from the Madrid Deep Space Communications Complex.

  3. Incidentally detected enhancing lesions found in breast MRI: analysis of apparent diffusion coefficient and T2 signal intensity significantly improves specificity

    Energy Technology Data Exchange (ETDEWEB)

    Arponen, Otso; Masarwah, Amro; Taina, Mikko [Kuopio University Hospital, Kuopio University Hospital, Diagnostic Imaging Centre, Department of Clinical Radiology, PO Box 1777, Kuopio (Finland); Kuopio University Hospital, University of Eastern Finland, Institute of Clinical Medicine, School of Medicine, Department of Clinical Radiology, PO Box 1777, Kuopio (Finland); Sutela, Anna; Koenoenen, Mervi; Hakumaeki, Juhana; Sudah, Mazen [Kuopio University Hospital, Kuopio University Hospital, Diagnostic Imaging Centre, Department of Clinical Radiology, PO Box 1777, Kuopio (Finland); Sironen, Reijo [Kuopio University Hospital, Kuopio University Hospital, Department of Pathology, PO Box 1777, Kuopio (Finland); Kuopio University Hospital, University of Eastern Finland, Institute of Clinical Medicine, School of Medicine, Clinical Pathology and Forensic Medicine, PO Box 1777, Kuopio (Finland); University of Eastern Finland, Cancer Center of Eastern Finland, Kuopio (Finland); Vanninen, Ritva [Kuopio University Hospital, Kuopio University Hospital, Diagnostic Imaging Centre, Department of Clinical Radiology, PO Box 1777, Kuopio (Finland); Kuopio University Hospital, University of Eastern Finland, Institute of Clinical Medicine, School of Medicine, Department of Clinical Radiology, PO Box 1777, Kuopio (Finland); University of Eastern Finland, Cancer Center of Eastern Finland, Kuopio (Finland)

    2016-12-15

    To evaluate the value of adding T2- and diffusion-weighted imaging (DWI) to the BI-RADS registered classification in MRI-detected lesions. This retrospective study included 112 consecutive patients who underwent 3.0T structural breast MRI with T2- and DWI on the basis of EUSOMA recommendations. Morphological and kinetic features, T2 signal intensity (T2 SI) and apparent diffusion coefficient (ADC) findings were assessed. Thirty-three (29.5 %) patients (mean age 57.0 ± 12.7 years) had 36 primarily MRI-detected incidental lesions of which 16 (44.4 %) proved to be malignant. No single morphological or kinetic feature was associated with malignancy. Both low T2 SI (P = 0.009) and low ADC values (≤0.87 x 10{sup -3} mm{sup 2}s{sup -1}, P < 0.001) yielded high specificity (80.0 %/80.0 %). The BI-RADS classification supplemented with information from DWI and T2-WI improved the diagnostic performance of the BI-RADS classification as sensitivity remained 100 % and specificity improved from 30 % to 65.0 %. The numbers of false positive lesions declined from 39 % (N = 14) to 19 % (N = 7). MRI-detected incidental lesions may be challenging to characterize as they have few specific malignancy indicating features. The specificity of MRI can be improved by incorporating T2 SI and ADC values into the BI-RADS assessment. (orig.)

  4. Performance of a mass spectrometer for determining low tritium levels from 3He/4He measurements

    International Nuclear Information System (INIS)

    Lynch, M.C.F.; Kay, D.J.

    1981-01-01

    The Micromass 3000 mass spectrometer is based on Clarke's 3 He/ 4 He instrument of McMaster University. The principal special features of the MM3000 are: (i) The double collector system, which uses an electron multiplier for the small 3 He + ion beams and a conventional Faraday detector for 4 He + ; (ii) The high sensitivity ion source; and (iii) The low-volume analyser tube employing static vacuum techniques. The sensitivity, resolution and background of the system are designed to permit measurement of 3 He and 4 He levels of the order of 10 -12 cm 3 STP and 10 -6 cm 3 STP, respectively, with a precision of 0.5%, although smaller quantities are detectable. The inherent resolution of the instrument is well in excess of 2000, but a resolution of 600-1000 is normally used for the 3 He + collector as this is sufficient to separate 3 He + from any interfering HD + or H + 3 ions. At this resolution 900 ions per second of 3 He + ions are obtained from 10 -12 cm 3 STP of 3 He. This is the size of 3 He samples obtained from water samples containing tritium at levels around 200 tritium units (1 tritium unit (TU) = IT/10 18 H). At lower tritium levels the 3 He + signal is correspondingly reduced, but the same techniques (described below) allow signals from 1-TU samples (5 ions/s) to be measured with good precision. The limit of detection is reached with quantities of 3 He in the region of 10 -15 cm 3 STP and tritium levels of around 0.1 TU. (author)

  5. Growth and dissolution of liquid 3He droplets in solid 4He matrix

    International Nuclear Information System (INIS)

    Gan'shin, A.N.; Grigor'ev, V.N.; Majdanov, V.A.; Penzev, A.A.; Rudavskij, Eh.Ya.; Rybalko, A.S.

    2000-01-01

    The phase separation kinetics of solid 3 He - 4 He mixtures was investigated using pressure measurements in the conditions when the two-phase system formed consists of concentrated phase liquid droplets (almost pure 3 He) in the dilute phase crystal matrix (almost pure 4 He). It is shown that the liquid droplet growth may be described by a sum of two exponential processes with small and large time contacts as cooling down step by step. This is a result of the strong influence of strains which appear in the crystal at the phase separation due to a large difference in molar volume between the phases and probably give rise to plastic deformation of the matrix and to non-equilibrium 3 He concentration in it. The 3 He atom transfer occurs only to the extent of strain relaxation. It is found that the cyclic growth and dissolution of the liquid droplets affect the crystal quality and lead to pressure increase. The coexistence of liquid and solid phases in droplets is speculated to be possible

  6. Correlation between standardized uptake value and apparent diffusion coefficient of neoplastic lesions evaluated with whole-body simultaneous hybrid PET/MRI.

    Science.gov (United States)

    Rakheja, Rajan; Chandarana, Hersh; DeMello, Linda; Jackson, Kimberly; Geppert, Christian; Faul, David; Glielmi, Christopher; Friedman, Kent P

    2013-11-01

    The purpose of this study was to assess the correlation between standardized uptake value (SUV) and apparent diffusion coefficient (ADC) of neoplastic lesions in the use of a simultaneous PET/MRI hybrid system. Twenty-four patients with known primary malignancies underwent FDG PET/CT. They then underwent whole-body PET/MRI. Diffusion-weighted imaging was performed with free breathing and a single-shot spin-echo echo-planar imaging sequence with b values of 0, 350, and 750 s/mm(2). Regions of interest were manually drawn along the contours of neoplastic lesions larger than 1 cm, which were clearly identified on PET and diffusion-weighted images. Maximum SUV (SUVmax) on PET/MRI and PET/CT images, mean SUV (SUVmean), minimum ADC (ADCmin), and mean ADC (ADCmean) were recorded on PET/MR images for each FDG-avid neoplastic soft-tissue lesion with a maximum of three lesions per patient. Pearson correlation coefficient was used to asses the following relations: SUVmax versus ADCmin on PET/MR and PET/CT images, SUVmean versus ADCmean, and ratio of SUVmax to mean liver SUV (SUV ratio) versus ADCmin. A subanalysis of patients with progressive disease versus partial treatment response was performed with the ratio of SUVmax to ADCmin for the most metabolically active lesion. Sixty-nine neoplastic lesions (52 nonosseous lesions, 17 bone metastatic lesions) were evaluated. The mean SUVmax from PET/MRI was 7.0 ± 6.0; SUVmean, 5.6 ± 4.6; mean ADCmin, 1.10 ± 0.58; and mean ADCmean, 1.48 ± 0.72. A significant inverse Pearson correlation coefficient was found between PET/MRI SUVmax and ADCmin (r = -0.21, p = 0.04), between SUVmean and ADCmean (r = -0.18, p = 0.07), and between SUV ratio and ADCmin (r = -0.27, p = 0.01). A similar inverse Pearson correlation coefficient was found between the PET/CT SUVmax and ADCmin. Twenty of 24 patients had previously undergone PET/CT; five patients had a partial treatment response, and six had progressive disease according to Response Evaluation

  7. Measurement of the Electrical Conductivity of He{sup 3} Plasma Induced by Neutron Irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Braun, J; Nygaard, K

    1966-03-15

    The conductivity of a He plasma created by the inelastic reaction with thermal neutrons: {sup 3}He + n{sub th} -> {sup 3}H + p + 0.76 MeV is studied as a function of neutron flux, gas temperature and gas density. Using reported values of the electron mobility the electron density is calculated from experimental conductivity values. Further, by accepting a reasonable value for the mean energy lost in creating one ion-pair, the recombination coefficient is estimated. The measurements performed so far cover temperatures between 300 - 1600 K and densities between 0.25 - 1 times the density at atmospheric pressure and 300 K. The neutron flux is varied between 10{sup 10} - 10{sup 11} n/cm{sup 2}/s. As a sample of results achieved at 1600 K and the lowest density (corresponding to about atmospheric pressure) and the highest neutron flux the following values are obtained for the conductivity, the electron density and the recombination coefficient respectively: {sigma} 0.2 S/m, n{sub e} 6x10{sup 11}/cm{sup 3}, {alpha} = 2xl0{sup -10} cm{sup 3}/s. An extrapolation of data obtained shows that the concept of neutron induced conductivity should be attractive for MHD power generation.

  8. Dynamic nuclear polarization and optimal control spatial-selective 13C MRI and MRS

    DEFF Research Database (Denmark)

    Vinding, Mads Sloth; Laustsen, Christoffer; Maximov, Ivan I.

    2013-01-01

    . This is achieved through the development of spatial-selective single-shot spiral-readout MRI and MRS experiments combined with dynamic nuclear polarization hyperpolarized [1-13C]pyruvate on a 4.7T pre-clinical MR scanner. The method stands out from related techniques by facilitating anatomic shaped region...

  9. Dispersion coefficients for H and He interactions with alkali-metal and alkaline-earth-metal atoms

    International Nuclear Information System (INIS)

    Mitroy, J.; Bromley, M.W.J.

    2003-01-01

    The van der Waals coefficients C 6 , C 8 , and C 10 for H and He interactions with the alkali-metal (Li, Na, K, and Rb) and alkaline-earth-metal (Be, Mg, Ca, and Sr) atoms are determined from oscillator strength sum rules. The oscillator strengths were computed using a combination of ab initio and semiempirical methods. The dispersion parameters generally agree with close to exact variational calculations for Li-H and Li-He at the 0.1% level of accuracy. For larger systems, there is agreement with relativistic many-body perturbation theory estimates of C 6 at the 1% level. These validations for selected systems attest to the reliability of the present dispersion parameters. About half the present parameters lie within the recommended bounds of the Standard and Certain compilation [J. Chem. Phys. 83, 3002 (1985)

  10. Variations of 3/He/4He isotope ratios within the Broadlands geothermal field, New Zealand

    International Nuclear Information System (INIS)

    Hulston, John; Lupton, John; University of California, Santa Barbara; Rosenberg, Nina

    1986-01-01

    The Broadlands-Ohaaki geothermal field is located 20 km NE of Wairakei on the Central Volcanic Zone of New Zealand. It falls within a resistivity low extending 4 km by 3 km. A study of 3 He/ 4 He ratios within this field has shown R/R A ratios close to 6.0 in the Ohaaki production area (NW). In contrast the production area to the SE on the east bank of the Waikato River has R/R A values close to 3.5. Differences in chemical ratios reported previously are found to correlate with the 3 He/ 4 He measurements. A tentative interpretation of the results indicate that there is a contribution of 3 He from the mantle and that the variations in the 3 He/ 4 He ratios are probably related to differences in the geochemistry of the rocks through which the geothermal fluids flow to the surface. Preliminary measurements of the argon isotopes also show a contribution from radiogenic rocks at depth

  11. Angular dependence of the sup(6)Li(πsup(+),sup(3)He)sup(3)He reaction

    International Nuclear Information System (INIS)

    McParland, B.J.; Auld, E.G.; Couvert, P.

    1985-02-01

    Angular distributions of the differential cross sections for the pionic fission sup(6)Li(πsup(+),sup(3)He)sup(3)He have been measured at pion energies of 60 and 80 MeV. The differential cross section is found to decrease monotonically with cossup(2)thetasup(*) and is compared with a theoretical prediction

  12. Accurate 3He polarimetry using the Rb Zeeman frequency shift due to the Rb-3He spin-exchange collisions

    International Nuclear Information System (INIS)

    Romalis, M.V.; Cates, G.D.

    1998-01-01

    We describe a method of 3 He polarimetry relying on the polarization-dependent frequency shift of the Rb Zeeman resonance. Our method is ideally suited for on-line measurements of the 3 He polarization produced by spin-exchange optical pumping. To calibrate the frequency shift we performed an accurate measurement of the imaginary part of the Rb- 3 He spin-exchange cross section in the temperature range typical for spin-exchange optical pumping of 3 He. We also present a detailed study of possible systematic errors in the frequency shift polarimetry. copyright 1998 The American Physical Society

  13. A sensitive zinc-activated 129Xe MRI probe

    International Nuclear Information System (INIS)

    Kotera, N.; Delacour, L.; Traore, T.; Buisson, D.A.; Taran, F.; Coudert, S.; Rousseau, B.; Tassali, N.; Leonce, E.; Boutin, C.; Berthault, P.; Brotin, T.; Dutasta, J.P.

    2012-01-01

    Herein we propose the use of hyper-polarized 129 Xe nuclear magnetic resonance (NMR) spectroscopy for the sensitive detection of Zn 2+ ions. To achieve this goal, the noble gas is encapsulated in dedicated host systems bearing a ligand that chelates the Zn 2+ ions. Cryptophanes, aromatic cage molecules made of cyclotriveratrylene groups, are perfectly suited to this purpose as 1) they can easily be rendered water-soluble, 2) the noble gas has a high affinity for their cavity, 3) when xenon is encapsulated, it takes a specific NMR frequency, and 4) xenon exchange in and out of the cavity insures a continuous refreshment of the Xe-cryptophane environment in hyper-polarization. We constructed a powerful 129 Xe NMR-based sensor of Zn 2+ ions, which enables for the first time measurement of Zn 2+ concentrations as low as 100 nm. This high sensitivity was achieved thanks to a smart 129 Xe MRI sensor, where the binding of the ion to the target is accompanied by a change in NMR parameters. We have also demonstrated the importance of working with enantiopure cryptophane derivatives. (O.M.)

  14. Neutron scattering lengths of 3He

    International Nuclear Information System (INIS)

    Alfimenkov, V.P.; Akopian, G.G.; Wierzbicki, J.; Govorov, A.M.; Pikelner, L.B.; Sharapov, E.I.

    1976-01-01

    The total neutron scattering cross-section of 3 He has been measured in the neutron energy range from 20 meV to 2 eV. Together with the known value of coherent scattering amplitude it leads to the two sts of n 3 He scattering lengths

  15. X-ray Debye-Waller factor measurements of solid 3He and 4He

    International Nuclear Information System (INIS)

    Arms, D.A.; Shah, R.S.; Simmons, R.O.

    2003-01-01

    X-ray synchrotron radiation was used to measure Debye-Waller factors of helium crystals for both 3 He and 4 He in both hcp and fcc phases. To our knowledge, there are no previous measurements for 3 He. The ranges studied for 3 He and 4 He crystals were 11.52-12.82 and 10.95-12.13 cm 3 , respectively, and 11.5-18.2 and 12.0-20.3 K. With small uncertainty, only a Gaussian dependence upon momentum transfer Q was found, and no anisotropy was detected in the hcp phase. Mean square atomic deviations, 2 >, and Lindemann ratios were obtained. Large Lindemann ratios confirm that these solids are highly anharmonic. The 2 > values agree within an average 1% with computations of Draeger and Ceperley from path integral Monte Carlo methods including unusual extrapolations to the thermodynamic limit. Because the path-integral Monte Carlo (PIMC) computations exhibit a T 3 dependence for 2 >, which also depends upon molar volume, an empirical analysis was made of the present data as well as of published x-ray and neutron data on hcp 4 He. The volume dependencies are similar to those found from calorimetry, over a large volume range, and the temperature dependencies show similar systematic variations with molar volume both in x-ray data and PIMC results

  16. Apparent violation of isospin symmetry in the 3H(3He,2H)4He reaction

    International Nuclear Information System (INIS)

    Rai, G.; Blyth, C.O.; England, J.B.A.; Farooq, A.; Karban, O.; Rawas, E.; Roman, S.; Vlastou, R.

    1988-01-01

    Angular distributions of the vector analyzing powers for the 3 H( 3 He, 2 H) 4 He reaction have been measured over the incident energy range 18--33 MeV. The measurements centered about 18 MeV display a deviation from the antisymmetric shape expected from isospin symmetry. Concentrating on the explanation of the 90 0 analyzing powers, we report the results of a distorted-wave Born approximation (DWBA) analysis which includes the direct and exchange processes and the spin-orbit potential. It is shown that the anomalous behavior of the 90 0 vector analyzing powers can be largely explained by the effect of a single F-wave potential resonance which leads to the magnification of the short-range differences between the 3 He and 3 H wave functions

  17. 12C(3He,3He n)11C cross section at 910 MeV

    International Nuclear Information System (INIS)

    Aslanides, E.; Fassnacht, P.; Dellacasa, G.; Gallio, M.; Tuyn, J.W.N.

    1981-01-01

    The 12 C( 3 He, 3 He n) 11 C cross section at 910 MeV was measured by using a Ge(Li) gamma spectrometer to determine the disintegration rate and measuring the incident flux by means of a scintillator telescope. Cross sections for the production of 7 Be in C and Al and for the production of 24 Na in Al are then determined using the measured cross section as a monitor

  18. On the thermophysical and transport properties of 3He and 4He: A bubble interaction potential versus state of the art.

    Science.gov (United States)

    Chrysos, Michael; Piel, Henri

    2017-07-21

    Three keynote thermophysical and transport properties of 3 He and 4 He, namely, the second virial coefficient, the shear viscosity, and the thermal conductivity, are reported for the "extended Dirac bubble potential" (EDbp), a novel model for He-He [M. Chrysos, J. Chem. Phys. 146, 024106 (2017)]. Comparisons with the experiment as well as with potentials with a proven track record and with the oversimplified Dbp are being made in the range 0.1-500 K to analyze the performance of the EDbp, which is shown here to emerge as a promising analytic model for He-He. A flowchart of how to treat the "buffer" in scattering cross section measurements is designed and conducted, offering a route to EDbp optimization. An impressive consistency with state-of-the-art calculations (which is just striking for such a simple analytic model) is found, essentially thanks to the performance of the phase-shift expression cotδ l  = λkr 0 ξ l y l (kr 0 )-y l (kr c )λkr 0 ξ l j l (kr 0 )-j l (kr c ), ξ l =j l (kr 0 )y l (kr c )-j l (kr c )y l (kr 0 ). A Multimedia view of δ l (k,r c ) versus k and r c is part of the material presented in this article. Data for the "best" r c (k) is given as a supplementary material.

  19. Final results for the excitation function and angular distributions of the 3H(d,n)4He reaction

    International Nuclear Information System (INIS)

    Tang Hongqing; Zhou Zuying; Qi Bujia; Zhou Chenwei; Du Yanfeng; Xia Haihong; Chen Zemin; Chen Zhenpeng; Chen Yingtang

    1998-01-01

    The final relative excitation function of the 3 H(d,n) 4 He rection at 0 degree is shown out. For comparison, a curve calculated from Drosg's HI-13 tandem is in progressplotted. The angular distributions of the 3 H(d,n) 4 He reaction at E d =13.36, 16.50 and 19.50 Mev in the center-of-mass system are shown out. A comparison of the legendre polynomial coefficients obtained from the present angular distribution data with Drosg's evaluation are reported

  20. 3He impurities on liquid 4He: possible existence of excited states

    International Nuclear Information System (INIS)

    Pavloff, N.; Treiner, J.

    1989-01-01

    We study, using a density functional approach, the properties of the two dimensional system formed by 3 He atoms on the surface of liquid 4 He, as a function of 3 He coverage N s . We find that the excited state recently proposed by Dalfovo and Stringari in the case of infinite dilution does survive when the number of surface 3 He atoms increases. For small values of N s , the surface tension σ is, as expected, linear in N s 2 . For N s ≅0.035 atom per square-Angstrom, i.e. half a monolayer, a new type of surface state starts being occupied, and this feature manifests itself by a change in the slope of σ as a function of N s 2 and, more clearly, by a discontinuity in the surface specific heat, which increases by a factor of almost 2. These predictions call for experimental investigations

  1. Quantification of regional early stage gas exchange changes using hyperpolarized "1"2"9Xe MRI in a rat model of radiation-induced lung injury

    International Nuclear Information System (INIS)

    Doganay, Ozkan; Stirrat, Elaine; McKenzie, Charles; Schulte, Rolf F.; Santyr, Giles E.

    2016-01-01

    Purpose: To assess the feasibility of hyperpolarized (HP) "1"2"9Xe MRI for detection of early stage radiation-induced lung injury (RILI) in a rat model involving unilateral irradiation by assessing differences in gas exchange dynamics between irradiated and unirradiated lungs. Methods: The dynamics of gas exchange between alveolar air space and pulmonary tissue (PT), PT and red blood cells (RBCs) was measured using single-shot spiral iterative decomposition of water and fat with echo asymmetry and least-squares estimation images of the right and left lungs of two age-matched cohorts of Sprague Dawley rats. The first cohort (n = 5) received 18 Gy irradiation to the right lung using a "6"0Co source and the second cohort (n = 5) was not irradiated and served as the healthy control. Both groups were imaged two weeks following irradiation when radiation pneumonitis (RP) was expected to be present. The gas exchange data were fit to a theoretical gas exchange model to extract measurements of pulmonary tissue thickness (L_P_T) and relative blood volume (V_R_B_C) from each of the right and left lungs of both cohorts. Following imaging, lung specimens were retrieved and percent tissue area (PTA) was assessed histologically to confirm RP and correlate with MRI measurements. Results: Statistically significant differences in L_P_T and V_R_B_C were observed between the irradiated and non-irradiated cohorts. In particular, L_P_T of the right and left lungs was increased approximately 8.2% and 5.0% respectively in the irradiated cohort. Additionally, V_R_B_C of the right and left lungs was decreased approximately 36.1% and 11.7% respectively for the irradiated cohort compared to the non-irradiated cohort. PTA measurements in both right and left lungs were increased in the irradiated group compared to the non-irradiated cohort for both the left (P < 0.05) and right lungs (P < 0.01) confirming the presence of RP. PTA measurements also correlated with the MRI measurements for both

  2. Radiogenic 3He/4He Estimates and Their Effect on Calculating Plio-Pleistocene Cosmogenic 3He Ages of Alluvial-Fan Terraces in the Lower Colorado River Basin, USA

    Science.gov (United States)

    Fenton, C.; Pelletier, J.

    2005-12-01

    Several alluvial-fan terraces near Topock, AZ were created by successive entrenchment of Pliocene and Pleistocene alluvial-fan gravels shed from the adjacent Black Mountains along the lower Colorado River corridor below Hoover Dam. These fans interfinger with and overlie main-stem Colorado River sands and gravels and grade to terrace levels that correspond with pre-existing elevations of the Colorado River. Absolute dates for the ages of Quaternary deposits on the lower Colorado River are rare and cosmogenic 3He age estimates of these surfaces would help constrain the timing of aggradation and incision in the lower Colorado River corridor. We analyzed individual basalt boulders from several terrace surfaces for total 3He/4He concentrations to calculate cosmogenic 3He ages of each fan terrace; 3He/4He values, expressed as R/Ra where Ra is the 3He/4He of air, range from 0.29 to 590. Black Mountain volcanic rocks have reported K-Ar ages between 15 and 30 Ma and basalt samples from adjacent alluvial fans contain 0.42 to 47× 1012 at/g of 4He, which has likely accumulated due to nuclear processes. The amount of radiogenic 3He/4He can be significant in old rocks with young exposure ages and can complicate determination of cosmogenic 3 He content. Alpha-decay of U, Th, and their daughter isotopes produces large amounts of 4He, whereas significant amounts of radiogenic 3He are only produced through the neutron bombardment of Li and subsequent beta-decay of tritium. We measured Li, U, Th, major and rare-earth element concentrations in whole-rock basalts and mineral separates. These concentrations are used to estimate the ratio of radiogenic helium contributed to the total helium system in our samples. Li concentrations typically range from 6 to 17 ppm, with one outlier of 62 ppm. U contents range from calculations predict that the average radiogenic helium (R/Ra) contributed to the total helium in Black Mountain basalt samples is 0.011. Other noble gas studies have shown

  3. Field dependence of T1 for hyperpolarized [1-13C]pyruvate

    DEFF Research Database (Denmark)

    Chattergoon, N.; Martnez-Santiesteban, F.; Handler, W. B.

    2013-01-01

    conformation and properties of the dissolution media such as buffer composition, solution pH, temperature and magnetic field. We have measured the magnetic field dependence of the spin–lattice relaxation time of hyperpolarized [1-13C]pyruvate using field-cycled relaxometry. [1-13C]pyruvate was hyperpolarized...

  4. Spin effects in medium-energy electron-3He scattering

    International Nuclear Information System (INIS)

    van den Brand, J.F.J.; Alarcon, R.; Bauer, T.

    1998-01-01

    New physics can be accessed by scattering polarized electrons from a polarized 3 He internal gas target. It is discussed how the asymmetries for the reactions 3 vector He(vector e,e'), 3 vector He(vector e,e'p), 3 vector He(vector e,e'n), 3 vector He(vector e,e'd), and 3 vector He(vector e,e'pn) may provide precise information on the S' and the D-wave parts of the 3 He ground-state wave function, the neutron form factors, and the role of spin-dependent reaction mechanism effects. The experiment uses up to 900 MeV (polarized) electrons from the AmPS storage ring in Amsterdam, Netherlands, in combination with large acceptance electron and hadron detectors. (orig.)

  5. Non-contrast 3D black blood MRI for abdominal aortic aneurysm surveillance: comparison with CT angiography

    Energy Technology Data Exchange (ETDEWEB)

    Zhu, Chengcheng; Leach, Joseph R.; Hope, Michael D. [University of California San Francisco, Department of Radiology and Biomedical Imaging, San Francisco, CA (United States); Tian, Bing; Liu, Qi; Lu, Jianping; Chen, Luguang [Changhai Hospital, Department of Radiology, Shanghai (China); Saloner, David [University of California San Francisco, Department of Radiology and Biomedical Imaging, San Francisco, CA (United States); Radiology Service, VA Medical Center, San Francisco, CA (United States)

    2017-05-15

    Management of abdominal aortic aneurysms (AAAs) is based on diameter. CT angiography (CTA) is commonly used, but requires radiation and iodinated contrast. Non-contrast MRI is an appealing alternative that may allow better characterization of intraluminal thrombus (ILT). This study aims to 1) validate non-contrast MRI for measuring AAA diameter, and 2) to assess ILT with CTA and MRI. 28 patients with AAAs (diameter 50.7 ± 12.3 mm) underwent CTA and non-contrast MRI. MRI was acquired at 3 T using 1) a conventional 3D gradient echo (GRE) sequence and 2) a 3D T{sub 1}-weighted black blood fast-spin-echo sequence. Two radiologists independently measured the AAA diameter. The ratio of signal of ILT and adjacent psoas muscle (ILT{sub r} = signal{sub ILT}/signal{sub Muscle}) was quantified. Strong agreement between CTA and non-contrast MRI was shown for AAA diameter (intra-class coefficient > 0.99). Both approaches had excellent inter-observer reproducibility (ICC > 0.99). ILT appeared homogenous on CTA, whereas MRI revealed compositional variations. Patients with AAAs ≥5.5 cm and <5.5 cm had a variety of distributions of old/fresh ILT types. Non-contrast 3D black blood MRI provides accurate and reproducible AAA diameter measurements as validated by CTA. It also provides unique information about ILT composition, which may be linked with elevated risk for disease progression. (orig.)

  6. Non-contrast 3D black blood MRI for abdominal aortic aneurysm surveillance: comparison with CT angiography

    International Nuclear Information System (INIS)

    Zhu, Chengcheng; Leach, Joseph R.; Hope, Michael D.; Tian, Bing; Liu, Qi; Lu, Jianping; Chen, Luguang; Saloner, David

    2017-01-01

    Management of abdominal aortic aneurysms (AAAs) is based on diameter. CT angiography (CTA) is commonly used, but requires radiation and iodinated contrast. Non-contrast MRI is an appealing alternative that may allow better characterization of intraluminal thrombus (ILT). This study aims to 1) validate non-contrast MRI for measuring AAA diameter, and 2) to assess ILT with CTA and MRI. 28 patients with AAAs (diameter 50.7 ± 12.3 mm) underwent CTA and non-contrast MRI. MRI was acquired at 3 T using 1) a conventional 3D gradient echo (GRE) sequence and 2) a 3D T_1-weighted black blood fast-spin-echo sequence. Two radiologists independently measured the AAA diameter. The ratio of signal of ILT and adjacent psoas muscle (ILT_r = signal_I_L_T/signal_M_u_s_c_l_e) was quantified. Strong agreement between CTA and non-contrast MRI was shown for AAA diameter (intra-class coefficient > 0.99). Both approaches had excellent inter-observer reproducibility (ICC > 0.99). ILT appeared homogenous on CTA, whereas MRI revealed compositional variations. Patients with AAAs ≥5.5 cm and <5.5 cm had a variety of distributions of old/fresh ILT types. Non-contrast 3D black blood MRI provides accurate and reproducible AAA diameter measurements as validated by CTA. It also provides unique information about ILT composition, which may be linked with elevated risk for disease progression. (orig.)

  7. Correlation between 3 T apparent diffusion coefficient values and grading of invasive breast carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Cipolla, Valentina, E-mail: valentina.cipolla@yahoo.it [Department of Radiological Sciences, University of Rome “Sapienza”, Viale del Policlinico 155, 00161 Rome (Italy); Santucci, Domiziana; Guerrieri, Daniele; Drudi, Francesco Maria [Department of Radiological Sciences, University of Rome “Sapienza”, Viale del Policlinico 155, 00161 Rome (Italy); Meggiorini, Maria Letizia [Department of Gynaecological Sciences, University of Rome “Sapienza”, Viale del Policlinico 155, 00161 Rome (Italy); Felice, Carlo de [Department of Radiological Sciences, University of Rome “Sapienza”, Viale del Policlinico 155, 00161 Rome (Italy)

    2014-12-15

    Highlights: • Apparent diffusion coefficient is a quantitative parameter which reflects molecular water movement. • Grading is an independent prognostic factor which correlates with other histopathological features. • Apparent diffusion coefficient values were significantly different between G1 and G3 classes. - Abstract: Purpose: The aim of this study was to evaluate whether the apparent diffusion coefficient (ADC) provided by 3.0 T (3 T) magnetic resonance diffusion-weighted imaging (DWI) varied according to the grading of invasive breast carcinoma. Materials and methods: A total of 92 patients with 96 invasive breast cancer lesions were enrolled; all had undergone 3 T magnetic resonance imaging (MRI) for local staging. All lesions were confirmed by histological analysis, and tumor grade was established according to the Nottingham Grading System (NGS). MRI included both dynamic contrast-enhanced and DWI sequences, and ADC value was calculated for each lesion. ADC values were compared with NGS classification using the Mann–Whitney U and the Kruskal–Wallis H tests. Grading was considered as a comprehensive prognostic factor, and Rho Spearman test was performed to determine correlation between grading and tumor size, hormonal receptor status, HER2 expression and Ki67 index. Pearson's Chi square test was carried out to compare grading with the other prognostic factors. Results: ADC values were significantly higher in G1 than in G3 tumors. No significant difference was observed when G1 and G3 were compared with G2. Tumor size, hormonal receptor status, HER2 expression and Ki67 index correlated significantly with grading but there was a significant difference only between G1 and G3 related to the ER and PR status, HER2 expression and Ki67 index. There was no statistically significant difference in lesion size between the two groups. Conclusion: ADC values obtained on 3 T DWI correlated with low-grade (G1) and high-grade (G3) invasive breast carcinoma. 3

  8. The 3H–3He Charge Radii Difference

    Directory of Open Access Journals (Sweden)

    Myers L. S.

    2016-01-01

    Full Text Available The upcoming E12-14-009 [1] experiment at Jefferson Lab will determine the ratio of the electric form factors for the A=3 mirror nuclei 3He and 3H. The measurement will use a 1.1 GeV electron beam, a special collimator plate to allow for simultaneous optics measurements, and the low-activity tritium target being prepared for Jefferson Lab. By observing the dependence of the form factor ratio as a function of Q2 over 0.05–0.09 GeV2, the dependence of the radii extraction on the shape of the form factors is minimized. As a result, we anticipate the uncertainty of the extracted charge radii difference to be 0.03 fm, a reduction of 70% from the current measurement. Using precise measurements of the 3He charge radius from isotopic shift or μHe measurements [2–4], we can deduce the absolute 3H charge radius. The results will provide a direct comparison to recent calculations of the charge radii.

  9. Oxygen-enhanced MRI of the lungs. Intraindividual comparison between 1.5 and 3 Tesla

    International Nuclear Information System (INIS)

    Dietrich, Olaf; Thieme, S.F.; Maxien, D.; Nikolaou, K.; Reiser, M.; Schoenberg, S.O.; Fink, C.

    2011-01-01

    Purpose: To assess the feasibility of oxygen-enhanced MRI of the lung at 3 Tesla and to compare signal characteristics with 1.5 Tesla. Materials and Methods: 13 volunteers underwent oxygen-enhanced lung MRI at 1.5 and 3 T with a T 1-weighted single-slice non-selective inversion-recovery single-shot half-Fourier fast-spin-echo sequence with simultaneous respiratory and cardiac triggering in coronal orientation. 40 measurements were acquired during room air breathing and subsequently during oxygen breathing (15 L/min, close-fitting face-mask). The signal-to-noise ratio (SNR) of the lung tissue was determined with a difference image method. The image quality of all acquisitions was visually assessed. The mean values of the oxygen-induced relative signal enhancement and its regional coefficient of variation were calculated and the signal enhancement was displayed as color-coded parameter maps. Oxygen-enhancement maps were visually assessed with respect to the distribution and heterogeneity of the oxygen-related signal enhancement at both field strengths. Results: The mean relative signal enhancement due to oxygen breathing was 13 % (± 5.6 %) at 1.5 T and of 9.0 % (± 8.0 %) at 3 T. The regional coefficient of variation was significantly higher at 3 T. Visual and quantitative assessment of the enhancement maps showed considerably less homogeneous distribution of the signal enhancement at 3 T. The SNR was not significantly different but showed a trend to slightly higher values (increase of about 10 %) at 3 T. Conclusion: Oxygen-enhanced pulmonary MRI is feasible at 3 Tesla. However, signal enhancement is currently more heterogeneous and slightly lower at 3 T. (orig.)

  10. Fine-structure relaxation of O(3P) induced by collisions with He, H and H2

    Science.gov (United States)

    Lique, F.; Kłos, J.; Alexander, M. H.; Le Picard, S. D.; Dagdigian, P. J.

    2018-02-01

    The excitation of fine-structure levels of O(3P) by collisions is an important cooling process in the interstellar medium (ISM). We investigate here spin-orbit (de-)excitation of O(3Pj, j = 0, 1, 2) induced by collisions with He, H and H2 based on quantum scattering calculations of the relevant rate coefficients in the 10-1000 K temperature range. The underlying potential energy surfaces are derived from highly correlated abinitio calculations. Significant differences were found with the rate coefficients currently used in astrophysical applications. In particular, our new rate coefficients for collisions with H are up to a factor of 5 lower. Radiative transfer computations allow the assessment of the astrophysical impact of these new rate coefficients. In the case of molecular clouds, the new data are found to increase slightly the flux of the 3P1 → 3P2, while decreasing the flux of the 3P0 → 3P1 line. In the case of atomic clouds, the flux of both lines is predicted to decrease. The new rate coefficients are expected to impact significantly the modelling of cooling in astrophysical environments while also allowing new insights into oxygen chemistry in the ISM.

  11. Study of the 6Li + p → 3He + 4He reaction in inverse kinematics

    International Nuclear Information System (INIS)

    Betsou, C.; Pakou, A.; Aslanoglou, X.; Nicolis, N.G.; Sgouros, O.; Soukeras, V.; Cappuzzello, F.; Acosta, L.; Agodi, C.; Carbone, D.; Cavallaro, M.; Di Pietro, A.; Fernandez-Garcia, J.P.; Figuera, P.; Fisichella, M.; Foti, A.; Keeley, N.; Marquinez-Duran, G.; Martel, I.; Mazzocco, M.; Strano, E.; Torresi, D.; Pierroutsakou, D.; Rusek, K.; Stiliaris, E.

    2015-01-01

    Angular distribution measurements were performed for the 6 Li + p → 3 He + 4 He reaction in inverse kinematics at incident energies of 2.7, 3.3, 4.2 and 4.8 MeV/u. The detection of both recoils ( 3 He and 4 He) over the laboratory angle range θ lab = 16 circle to 34 circle allowed the determination of the angular distribution over a wide angular range in the center-of-mass frame (θ c.m. ∝ 40 circle to 140 circle ). The results clarify inconsistencies between existing data sets and are consistent with compound nucleus model calculations. (orig.)

  12. Opportunities for Polarized He-3 in RHIC and EIC

    Energy Technology Data Exchange (ETDEWEB)

    Aschenauer E.; Deshpande, A.; Fischer, W.; Derbenev, S.; Milner, R.; Roser, T.; Zelenski, A.

    2011-10-01

    The workshop on opportunities for polarized He-3 in RHIC and EIC was targeted at finding practical ways of implementing and using polarized He-3 beams. Polarized He-3 beams will provide the unique opportunity for first measurements, i.e, to a full quark flavor separation measuring single spin asymmetries for p{sup +}, p{sup -} and p{sup 0} in hadron-hadron collisions. In electron ion collisions the combination of data recorded with polarized electron proton/He-3 beams allows to determine the quark flavor separated helicity and transverse momentum distributions. The workshop had sessions on polarized He-3 sources, the physics of colliding polarized He-3 beams, polarimetry, and beam acceleration in the AGS Booster, AGS, RHIC, and ELIC. The material presented at the workshop will allow making plans for the implementation of polarized He-3 beams in RHIC.

  13. Backward elastic p3He-scattering and high momentum components of 3He wave function

    International Nuclear Information System (INIS)

    Uzikov, Yu.N.

    1998-01-01

    It is shown that owing to a dominance of np-pair transfer mechanism of backward elastic p 3 He-scattering for incident proton kinetic energies T p > 1 GeV the cross section of this process is defined mainly by the values of the Faddeev component of the wave function of 3 He nucleus, φ 23 (q 23 , p 1 ), at high relative momenta q 23 > 0.6 GeV/c of the NN-pair in the 1 S 0 -state and at low spectator momenta p 1 ∼ 0 - 0.2 GeV/c

  14. Electric dipole moment of 3He

    International Nuclear Information System (INIS)

    Avishai, Y.; Fabre de la Ripelle, M.

    1987-01-01

    The contribution of CP violating nucleon-nucleon interaction to the electric dipole moment of 3 He is evaluated following a recent proposal for its experimental detection. Two models of CP violating interactions are used, namely, the Kobayashi-Maskawa mechanism and the occurrence of the Θ term in the QCD lagrangian. These CP violating interactions are combined with realistic strong nucleon-nucleon interactions to induce a CP forbidden component of the 3 He wave function. The matrix element of the electric dipole operator is then evaluated between CP allowed and CP forbidden components yielding the observable electric dipole moment. Using the parameters emerging from the penguin terms in the Kobaysashi-Maskawa model we obtain a result much larger than the electric dipole moment of the neutron in the same model. On the other hand, no enhancement is found for the Θ-term mechanism. A possible explanation for this difference is discussed. Numerical estimates can be given only in the Kobayashi-Maskawa model, giving d( 3 He) ≅ 10 30 e . cm. In the second mechanism, the estimate give d ( 3 He) ≅ 10 16 anti Θ. (orig.)

  15. Superfluidity in two-dimensions. A thermal conductivity study of 4He and 3He- 4He mixture films

    International Nuclear Information System (INIS)

    Finotello, D.

    1992-01-01

    We review measurement of the thermal transport of 4 He films and 3 He- 4 He mixture films near the superfluid transition. These measurements were performed on helium films of thickness ranging from 12 to 156 A and mixture films with 3 He concentration up to 2%. The superfluid transition temperature for these films ranged from 1.2 to 2.2. K. We discuss universal features of the data as well as the behavior of the ratio of the vortex diffusion constant to vortex core-parameter, the sharpness of the transition and the superfluid transition temperature as a function of thickness and concentration. We also describe new experiments that will contribute to a better understanding of the observed behavior (Author)

  16. Quantitative multiparametric MRI in uveal melanoma: increased tumor permeability may predict monosomy 3

    Energy Technology Data Exchange (ETDEWEB)

    Kamrava, Mitchell; Wang, Pin-Chieh; Roberts, Kristofer; Demanes, D.J. [University of California Los Angeles, Department of Radiation Oncology, Los Angeles, CA (United States); Sepahdari, Ali R.; Leu, Kevin; Ellingson, Benjamin M. [University of California Los Angeles, Department of Radiological Sciences, Los Angeles, CA (United States); McCannel, Tara [University of California Los Angeles, Department of Ophthalmology, Los Angeles, CA (United States)

    2015-08-15

    Uveal melanoma is a rare intraocular tumor with heterogeneous biological behavior, and additional noninvasive markers that may predict outcome are needed. Diffusion- and perfusion-weighted imaging may prove useful but have previously been limited in their ability to evaluate ocular tumors. Our purpose was to show the feasibility and potential value of a multiparametric (mp-) MRI protocol employing state of the art diffusion- and perfusion-weighted imaging techniques. Sixteen patients with uveal melanoma were imaged with mp-MRI. Multishot readout-segmented echoplanar diffusion-weighted imaging, quantitative dynamic contrast-enhanced (DCE) MR perfusion imaging, and anatomic sequences were obtained. Regions of interest (ROIs) were drawn around tumors for calculation of apparent diffusion coefficient (ADC) and perfusion metrics (K{sup trans}, v{sub e}, k{sub ep}, and v{sub p}). A generalized linear fit model was used to compare various MRI values with the American Joint Commission on Cancer (AJCC) tumor group and monosomy 3 status with significance set at P < 0.05. mp-MRI was performed successfully in all cases. MRI tumor height (mean [standard deviation]) was 6.5 mm (3.0). ROI volume was 278 mm{sup 3} (222). ADC was 1.07 (0.27) x 10-3 mm{sup 2}/s. DCE metrics were K{sup trans} 0.085/min (0.063), v{sub e} 0.060 (0.052), k{sub ep} 1.20/min (0.32), and v{sub p} 1.48 % (0.82). Patients with >33 % monosomy 3 had higher K{sup trans} and higher v{sub e} values than those with disomy 3 or ≤33 % monosomy (P < 0.01). There were no significant differences between ADC (P = 0.07), k{sub ep} (P = 0.37), and v{sub p} with respect to monosomy 3. mp-MRI for ocular tumor imaging using multishot EPI DWI and quantitative DCE perfusion is technically feasible. mp-MRI may help predict monosomy 3 in uveal melanoma. (orig.)

  17. Three-critical phenomena in the He3-He4 mixture

    International Nuclear Information System (INIS)

    Carvalho Filho, C.A.A. de.

    1976-07-01

    A review of the phenomenology of tricritical behaviour in He 3 -He 4 mixtures is made. Starting from a model proposed by Blume, Emery and Griffiths the tricritical transition is investigated by means of the Renormalization Group making use of the Callan-Symanzik equation and usual perturbative methods of Relativistic Quantum Field Theory. Mean-field tricritical exponents and logarithmic corrections are found in a sup(n) unified context. The structure of scaling laws is also studied. (author) [pt

  18. 3He functions in tokamak-pumped laser systems

    International Nuclear Information System (INIS)

    Jassby, D.L.

    1986-10-01

    3 He placed in an annular cell around a tokamak fusion generator can convert moderated fusion neutrons to energetic ions by the 3 He(n,p)T reaction, and thereby excite gaseous lasants mixed with the 3 He while simultaneously breeding tritium. The total 3 He inventory is about 4 kg for large tokamak devices. Special configurations of toroidal-field magnets, neutron moderators and beryllium reflectors are required to permit nearly uniform neutron current into the laser cell with minimal attenuation. The annular laser radiation can be combined into a single output beam at the top of the tokamak

  19. Diagnostic performance of conventional MRI parameters and apparent diffusion coefficient values in differentiating between benign and malignant soft-tissue tumours.

    Science.gov (United States)

    Song, Y; Yoon, Y C; Chong, Y; Seo, S W; Choi, Y-L; Sohn, I; Kim, M-J

    2017-08-01

    To compare the abilities of conventional magnetic resonance imaging (MRI) and apparent diffusion coefficient (ADC) in differentiating between benign and malignant soft-tissue tumours (STT). A total of 123 patients with STT who underwent 3 T MRI, including diffusion-weighted imaging (DWI), were retrospectively analysed using variate conventional MRI parameters, ADC mean and ADC min . For the all-STT group, the correlation between the malignant STT conventional MRI parameters, except deep compartment involvement, compared to those of benign STT were statistically significant with univariate analysis. Maximum diameter of the tumour (p=0.001; odds ratio [OR], 8.97) and ADC mean (p=0.020; OR, 4.30) were independent factors with multivariate analysis. For the non-myxoid non-haemosiderin STT group, signal heterogeneity on axial T1-weighted imaging (T1WI; p=0.017), ADC mean , and ADC min (p=0.001, p=0.001), showed significant differences with univariate analysis between malignancy and benignity. Signal heterogeneity in axial T1WI (p=0.025; OR, 12.64) and ADC mean (p=0.004; OR, 33.15) were independent factors with multivariate analysis. ADC values as well as conventional MRI parameters were useful in differentiating between benign and malignant STT. The ADC mean was the most powerful diagnostic parameter in non-myxoid non-haemosiderin STT. Copyright © 2017 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  20. Experimental Study of Photon Induced Reactions on 3He and 4He at Low Energies

    International Nuclear Information System (INIS)

    Tornow, W.

    2011-01-01

    Data are reported for the photodisintegration cross section of the reaction 3 He(γ, p) 2 H at ten energies between 7.0 and 16.0 MeV. Very preliminary data are presented for the reaction 4 He(γ, p) 3 H between 22.0 and 29.5 MeV in 0.5 MeV energy steps, and for the reaction 4 He(γ, n) 3 He at three energies around 28.0 MeV. High-pressure He/Xe gas scintillators served as target and detector. Our data are in better agreement with recent theoretical calculations than the majority of the existing data for all three reactions, but differ significantly from recent data taken with a mono-energetic photon beam and a time-projection chamber. (author)

  1. Neutron polarization in polarized 3He targets

    International Nuclear Information System (INIS)

    Friar, J.L.; Gibson, B.F.; Payne, G.L.; Bernstein, A.M.; Chupp, T.E.

    1990-01-01

    Simple formulas for the neutron and proton polarizations in polarized 3 He targets are derived assuming (1) quasielastic final states; (2) no final-state interactions; (3) no meson-exchange currents; (4) large momentum transfers; (5) factorizability of 3 He SU(4) response-function components. Numerical results from a wide variety of bound-state solutions of the Faddeev equations are presented. It is found that this simple model predicts the polarization of neutrons in a fully polarized 3 He target to be 87%, while protons should have a slight residual polarization of -2.7%. Numerical studies show that this model works very well for quasielastic electron scattering

  2. The osmotic pressure of 3He-4He mixtures along the phase separation curve

    NARCIS (Netherlands)

    van de Klundert, L.J.M.; Bos, M.R.E.; van der Meij, J.A.M.; Steffens, H.A.

    1977-01-01

    The osmotic pressure of 3He-4He mixtures was measured along the phase separation curve at temperatures up to 500 mK by balancing it with the fountain pressure of pure 4He. The usefullness of the secondary osmotic pressure thermometer was reinvestigated.

  3. The osmotic pressure of 3He-4He mixtures along the phase separation curve

    International Nuclear Information System (INIS)

    Klundert, L.J.M. van de; Bos, M.R.E.; Meij, J.A.M. van der; Steffens, H.A.

    1977-01-01

    The osmotic pressure of 3 He- 4 He mixtures was measured along the phase separation curve at temperatures up to 500 mK by balancing it with the fountain pressure of pure 4 He. The usefullness of the secondary osmotic pressure thermometer was reinvestigated. (Auth.)

  4. Exchange currents in low-energy nucleon capture by 3He

    International Nuclear Information System (INIS)

    Wervelman, Rob.

    1991-01-01

    The studies described in this thesis concern absolute cross-section measurements of the radiative neutron capture reactions 3 He (n,γ) 4 He and 3 He(n,γγ) 4 He, and are complements with shell-model calculations on the radiative thermal neutron capture reaction by 3 He and on the weak 3 He(p,e + ν e ) 4 He reaction. The experiments have been performed at two neutron energies, with sub-thermal neutrons where s-wave capture is dominant, and with a quasi-monochromatic 24.5 keV neutron beam (p-wave capture). It has been found that the thermal neutron capture cross section of 3 He is 55±3 μb. Measured at 24.5 keV-neutron energy, the radiative capture cross section for p-wave neutrons turned out to be 9.1±0.8 μb. A measurement on the double-photon reaction 3 He(n th ,γγ) has yielded a cross-section value of 30±80 μb. In the theoretical part of the work a standard model of nuclear weak and electromagnetic interaction currents, consisting of a one-body impulse approximation and a two-body meson-exchange current part, has been applied to the process of nucleon capture by 3 He. Within the framework of a (0+2) (h/2π)ω shell-model calculation, using Sussex matrix elements for the 3 He and 4 He ground state wave functions, the empirical radiative cross sections for thermal neutrons of 3 He could be reproduced with satisfactory agreement. The total MEC correction to the radiative thermal neutron capture cross section is rather small because large cancellations occur between the various contributions. In the 3 He(p,e + ν e ) 4 He reaction meson-exchange contributions enlarge the astrophysical S-factor by more than a factor two. The matrix element ratio of the weak 3 He+p and the electromagnetic 3 He+n reaction is calculated to be (4.3±0.6)g A C 0 . This ratio has been found to be fairly insensitive to the percentage D-state admixtures in the 3 He and 4 He ground state wave functions. (author). 129 refs.; 24 figs.; 5 tabs

  5. The (3He,t) and (d,2He)reactions at intermediate energies

    International Nuclear Information System (INIS)

    Brockstedt, A.

    1987-09-01

    The ( 3 He,t) reaction has been studied at 0.6-2.3 GeV at small scattering angles, 0-7 degrees, on various nuclei ( 12 C, 13 C, 26 Mg, 40 Ca, 48 Ca, 54 Fe, 90 Zr, 159 Tb, 208 Pb) including a proton target. The reaction is a single-step reaction and selects the spin-isospin channel. Angular distributions for low-lying states in 12 N are well described by DWIA calculations. From 13 C to 13 N transitions the ratio J στ /J τ , at momentum transfer, q, close to zero, is derived. The ratio remains roughly constant in the region 300 - 700 MeV/nucleon. The position of the quasi-free peak is shifted compared with free nucleon-nucleon scattering. The shift is towards higher excitation energies at q approx 1.4 fm -1 , and towards lower excitation energies at q approx 2.5 fm -1 . The p( 3 He,t)Δ ++ reaction is analysed as one-pion exchange and the ( 3 He,t) form factor is extracted. The shape and position of the Δ resonance seem to be independent of target mass for the targets studied. Compared with the p to Δ ++ transition the position is shifted towards lower excitation energy in nuclei. The (d,2p[ 1 S 0 ]) reaction, with the two protons in an 1 S 0 state labelled 2 He, is studied at 0.65 and 2.0 GeV at small angles, 0-4 degrees, on some of the targets used in the ( 3 He,t) experiment (p, 12 C, 40 Ca, 54 Fe). This reaction is also a one-step reaction that can be used for studies of spin-isospin excitations. Cross sections and tensor analysing powers are determined for the p(d, 2 He)n reaction. These results are compared with PWIA calculations. The Δ resonance in carbon is also here shifted down in excitation energy compared with the proton target. (author)

  6. Development of high-performance alkali-hybrid polarized 3He targets for electron scattering

    Science.gov (United States)

    Singh, Jaideep T.; Dolph, P. A. M.; Tobias, W. A.; Averett, T. D.; Kelleher, A.; Mooney, K. E.; Nelyubin, V. V.; Wang, Yunxiao; Zheng, Yuan; Cates, G. D.

    2015-05-01

    Background: Polarized 3He targets have been used as effective polarized neutron targets for electron scattering experiments for over twenty years. Over the last ten years, the effective luminosity of polarized 3He targets based on spin-exchange optical pumping has increased by over an order of magnitude. This has come about because of improvements in commercially-available lasers and an improved understanding of the physics behind the polarization process. Purpose: We present the development of high-performance polarized 3He targets for use in electron scattering experiments. Improvements in the performance of polarized 3He targets, target properties, and operating parameters are documented. Methods: We utilize the technique of alkali-hybrid spin-exchange optical pumping to polarize the 3He targets. Spectrally narrowed diode lasers used for the optical pumping greatly improved the performance. A simulation of the alkali-hybrid spin-exchange optical pumping process was developed to provide guidance in the design of the targets. Data was collected during the characterization of 24 separate glass target cells, each of which was constructed while preparing for one of four experiments at Jefferson Laboratory in Newport News, Virginia. Results: From the data obtained we made determinations of the so-called X -factors that quantify a temperature-dependent and as-yet poorly understood spin-relaxation mechanism that limits the maximum achievable 3He polarization to well under 100%. The presence of the X -factor spin-relaxation mechanism was clearly evident in our data. Good agreement between the simulation and the actual target performance was obtained by including details such as off-resonant optical pumping. Included in our results is a measurement of the K -3He spin-exchange rate coefficient kseK=(7.46 ±0.62 ) ×10-20cm3/s over the temperature range 503 K to 563 K. Conclusions: In order to achieve high performance under the operating conditions described in this paper

  7. A miniature adsorption3HE refrigerator

    International Nuclear Information System (INIS)

    Duband, L.; Ravex, A.; Lange, A.

    1991-01-01

    A self-contained, recyclable laboratory 3 He refrigerator has been developed. The refrigerator is very compact, portable and is designed to be safe and reliable. The unit can easily be installed on the cold plate of a superfluid 4 He cryostat. Once bolted on the cold plate, operation of the refrigerator is controlled by a single heater. In this new design the refrigerator has a cylindrical geometry. The adsorption pump is placed above the condensation point to prevent convection during the condensation phase and to improve the pumping speed. The inhibition of convection reduces the load on the 4 He bath and increases the condensation efficiency. This refrigeration technique has great potential for space applications. The absence of moving parts makes the system reliable and vibration free. Its simplicity and the absence of external components facilitate its integration on a cryostat. In fact, a rocket-borne 3 He refrigerator has already been successfully flown and has demonstrated the feasibility of this method

  8. Primary populations of metastable antiprotonic $^{4}He$ and $^{3}He$ atoms

    CERN Document Server

    Hori, Masaki; Hayano, R S; Ishikawa, T; Sakuguchi, J; Tasaki, T; Widmann, E; Yamaguchi, H; Torii, H A; Juhász, B; Horváth, D; Yamazaki, T

    2002-01-01

    Initial population distributions of metastable antiprotonic **4He and **3He atoms over principal and angular momentum quantum numbers were investigated using laser spectroscopy. The total fractions of antiprotons captured into the metastable states of the atoms were deduced. Cascade calculations were performed using the measure populations to reproduce the delayed annihilation time spectrum. Results showed agreement between the simulated and measured spectra. (Edited abstract) 30 Refs.

  9. Effects of {Delta}-isobar degrees of freedom on the reactions {sup 3}He(n,{gamma}){sup 4}He and {sup 3}He(p,e{sup +}{nu}{sub e}){sup 4}He at low-energy

    Energy Technology Data Exchange (ETDEWEB)

    Schiavilla, R.

    1991-12-31

    The cross sections of the radiative {sup 3}He(n,{gamma}){sup 4}He and weak {sup 3}He(p,e{sup +}{nu}{sub e}){sup 4}He capture reactions at thermal neutron and keV proton energies have been calculated with the Variational Monte Carlo method. The ground state and low-energy continuum wave functions have been determined variationally from a realistic Hamiltonian, and include both nucleon and {Delta}-isobar degrees of freedom. The electroweak transition operator contains one- and two-body components in the N + {Delta} Hilbert space.

  10. Effects of. Delta. -isobar degrees of freedom on the reactions sup 3 He(n,. gamma. ) sup 4 He and sup 3 He(p,e sup +. nu. sub e ) sup 4 He at low-energy

    Energy Technology Data Exchange (ETDEWEB)

    Schiavilla, R.

    1991-01-01

    The cross sections of the radiative {sup 3}He(n,{gamma}){sup 4}He and weak {sup 3}He(p,e{sup +}{nu}{sub e}){sup 4}He capture reactions at thermal neutron and keV proton energies have been calculated with the Variational Monte Carlo method. The ground state and low-energy continuum wave functions have been determined variationally from a realistic Hamiltonian, and include both nucleon and {Delta}-isobar degrees of freedom. The electroweak transition operator contains one- and two-body components in the N + {Delta} Hilbert space.

  11. MRI findings in acute Hendra virus meningoencephalitis

    Energy Technology Data Exchange (ETDEWEB)

    Nakka, P.; Amos, G.J. [Department of Diagnostic Radiology, Princess Alexandra Hospital, Woolloongabba, Qld 4102 (Australia); Saad, N., E-mail: nivena100@hotmail.com [Department of Diagnostic Radiology, Princess Alexandra Hospital, Woolloongabba, Qld 4102 (Australia); Jeavons, S. [Department of Diagnostic Radiology, Princess Alexandra Hospital, Woolloongabba, Qld 4102 (Australia)

    2012-05-15

    Aim: To describe serial changes in brain magnetic resonance imaging (MRI) in acute human infection from two outbreaks of Hendra virus (HeV), relate these changes to disease prognosis, and compare HeV encephalitis to reported cases of Nipah virus encephalitis. Materials and methods: The MRI images of three human cases (two of which were fatal) of acute HeV meningoencephalitis were reviewed. Results: Cortical selectivity early in the disease is evident in all three patients, while deep white matter involvement appears to be a late and possibly premorbid finding. This apparent early grey matter selectivity may be related to viral biology or ribavirin pharmacokinetics. Neuronal loss is evident at MRI, and the rate of progression of MRI abnormalities can predict the outcome of the infection. In both fatal cases, the serial changes in the MRI picture mirrored the clinical course. Conclusion: This is the first comprehensive report of serial MRI findings in acute human cerebral HeV infection from two outbreaks. The cortical selectivity appears to be an early finding while deep white matter involvement a late, and possibly premorbid, finding. In both fatal cases, the serial changes in MRI mirrored the clinical course.

  12. MRI findings in acute Hendra virus meningoencephalitis

    International Nuclear Information System (INIS)

    Nakka, P.; Amos, G.J.; Saad, N.; Jeavons, S.

    2012-01-01

    Aim: To describe serial changes in brain magnetic resonance imaging (MRI) in acute human infection from two outbreaks of Hendra virus (HeV), relate these changes to disease prognosis, and compare HeV encephalitis to reported cases of Nipah virus encephalitis. Materials and methods: The MRI images of three human cases (two of which were fatal) of acute HeV meningoencephalitis were reviewed. Results: Cortical selectivity early in the disease is evident in all three patients, while deep white matter involvement appears to be a late and possibly premorbid finding. This apparent early grey matter selectivity may be related to viral biology or ribavirin pharmacokinetics. Neuronal loss is evident at MRI, and the rate of progression of MRI abnormalities can predict the outcome of the infection. In both fatal cases, the serial changes in the MRI picture mirrored the clinical course. Conclusion: This is the first comprehensive report of serial MRI findings in acute human cerebral HeV infection from two outbreaks. The cortical selectivity appears to be an early finding while deep white matter involvement a late, and possibly premorbid, finding. In both fatal cases, the serial changes in MRI mirrored the clinical course.

  13. Geometrical aspects of reaction cross sections for 3He, 4He and 12C projectiles

    International Nuclear Information System (INIS)

    Ingemarsson, A.; Lantz, M.

    2003-04-01

    A black-disc model combined with accurate matter densities has been used for an investigation of reaction cross sections for 3 He, 4 He and 12 C projectiles. A simple relation is derived between the energy dependence of the reaction cross sections and the strength of the nucleon-nucleon interaction. A comparison is also made of the reaction cross sections for 3 He and 4 He for six different nuclei 12 C, 16 O, 40 Ca, 58,60 Ni and 208 Pb

  14. Monitoring mammary tumor progression and effect of tamoxifen treatment in MMTV-PymT using MRI and magnetic resonance spectroscopy with hyperpolarized [1-13C]pyruvate

    DEFF Research Database (Denmark)

    Asghar Butt, Sadia; Søgaard, Lise V.; Ardenkjær-Larsen, Jan Henrik

    2015-01-01

    Purpose: To use dynamic magnetic resonance spectroscopy (MRS) of hyperpolarized 13C-pyruvate to follow the progress over time in vivo of breast cancer metabolism in the MMTV-PymT model, and to follow the response to the anti-estrogen drug tamoxifen. Methods: Tumor growth was monitored by anatomical...... significantly in the treated group. Conclusion: These hyperpolarized 13C MRS findings indicate that tumor metabolic changes affects kP. The measured kp did not relate to treatment response to the same extent as did tumor growth, histological evaluation, and in vitro determination of LDH activity. © 2014 Wiley...

  15. 186Os and 187Os enrichments and high-3He/4He sources in the Earth's mantle

    DEFF Research Database (Denmark)

    Brandon, A.D.; Graham, D.W.; Waight, Tod Earle

    2007-01-01

    at present remains core-mantle interaction. While some plumes with high 3He/4He, such as Hawaii, appear to have been subjected to detectable addition of Os (and possibly He) from the outer core, others such as Iceland do not. A positive correlation between 187Os/188Os and 3He/4He from 9.6 to 19 Ra in Iceland...

  16. Diagnosis of rotator cuff tears using 3-Tesla MRI versus 3-Tesla MRA: a systematic review and meta-analysis.

    Science.gov (United States)

    McGarvey, Ciaran; Harb, Ziad; Smith, Christian; Houghton, Russell; Corbett, Steven; Ajuied, Adil

    2016-02-01

    To compare the diagnostic accuracy of magnetic resonance imaging (MRI), 2-dimensional magnetic resonance arthrogram (MRA) and 3-dimensional isotropic MRA in the diagnosis of rotator cuff tears when performed exclusively at 3-T. A systematic review was undertaken of the Cochrane, MEDLINE and PubMed databases in accordance with the PRISMA guidelines. Studies comparing 3-T MRI or 3-T MRA (index tests) to arthroscopic surgical findings (reference test) were included. Methodological appraisal was performed using QUADAS 2. Pooled sensitivity and specificity were calculated and summary receiver-operating curves generated. Kappa coefficients quantified inter-observer reliability. Fourteen studies comprising 1332 patients were identified for inclusion. Twelve studies were retrospective and there were concerns regarding index test bias and applicability in nine and six studies respectively. Reference test bias was a concern in all studies. Both 3-T MRI and 3-T MRA showed similar excellent diagnostic accuracy for full-thickness supraspinatus tears. Concerning partial-thickness supraspinatus tears, 3-T 2D MRA was significantly more sensitive (86.6 vs. 80.5 %, p = 0.014) but significantly less specific (95.2 vs. 100 %, p Tesla 3D isotropic MRA showed similar accuracy to 3-T conventional 2D MRA. Three-Tesla MRI appeared equivalent to 3-T MRA in the diagnosis of full- and partial-thickness tears, although there was a trend towards greater accuracy in the diagnosis of subscapularis tears with 3-T MRA. Three-Tesla 3D isotropic MRA appears equivalent to 3-T 2D MRA for all types of tears.

  17. Direct harvesting of Helium-3 (3He) from heavy water nuclear reactors

    International Nuclear Information System (INIS)

    Bentoumi, G.; Didsbury, R.; Jonkmans, G.; Rodrigo, L.; Sur, B.

    2013-01-01

    The thermal neutron activation of deuterium inside a heavy-water-moderated or -cooled nuclear reactor produces a build-up of tritium in the heavy water. The in situ decay of tritium can, for certain reactor types and operating conditions, produce potentially useable amounts of 3 He, which can be directly extracted via the heavy-water cover gas without first separating, collecting and storing tritium outside the reactor. It is estimated that the amount of 3 He available for recovery from the moderator cover gas of a 700 MWe class Pressurized Heavy Water Reactor (PHWR) ranges from 0.1 to 0.7 m 3 (STP) per annum, varying with the tritium activity buildup in the moderator. The harvesting of 3 He would generate approximately 12.7 m 3 (STP) of 3 He, worth more than $30M at current market rates, over a typical 25-year operating cycle of the PHWR. This paper discusses the production of 3 He in the moderator of a PHWR and its extraction from the 4 He moderator cover gas system using conventional methods. (author)

  18. The helium flux from the continents and ubiquity of low-3He/4He recycled crust and lithosphere

    Science.gov (United States)

    Day, James M. D.; Barry, Peter H.; Hilton, David R.; Burgess, Ray; Pearson, D. Graham; Taylor, Lawrence A.

    2015-03-01

    New helium isotope and trace-element abundance data are reported for pyroxenites and eclogites from South Africa, Siberia, and the Beni Bousera Massif, Morocco that are widely interpreted to form from recycled oceanic crustal protoliths. The first He isotope data are also presented for Archaean peridotites from the Kaapvaal (South Africa), Slave (Canada), and Siberian cratons, along with recently emplaced off-craton peridotite xenoliths from Kilbourne Hole, San Carlos (USA) and Vitim (Siberia), to complement existing 3He/4He values obtained for continental and oceanic peridotites. Helium isotope compositions of peridotite xenoliths vary from 7.3 to 9.6 RA in recently (volcanics that contain a contribution from asthenospheric sources. Using the new He isotope data for cratonic peridotites and assuming that significant portions (>50%) of the Archaean and Proterozoic continental lithospheric mantle are stable and unaffected by melt or fluid infiltration on geological timescales (>0.1 Ga), and that U and Th contents vary between cratonic lithosphere and non-cratonic lithosphere, calculations yield a 3He flux of 0.25-2.2 atoms/s/cm2 for the continental lithospheric mantle. These estimates differ by a factor of ten from non-cratonic lithospheric mantle and are closer to the observed 3He flux from the continents (<1 atoms/s/cm2). Pyroxenites and eclogites from the continental regions are all characterized by 3He/4He (0.03-5.6 RA) less than the depleted upper mantle, and relatively high U and Th contents. Together with oceanic and continental lithospheric peridotites, these materials represent reservoirs with low time-integrated 3He/(U + Th) in the mantle. Pyroxenites and eclogites are also characterized by higher Fe/Mg, more radiogenic Os-Pb isotope compositions, and more variable δ18O values (∼3‰ to 7‰), compared with peridotitic mantle. These xenoliths are widely interpreted to be the metamorphic/metasomatic equivalents of recycled oceanic crustal protoliths. The

  19. DW MRI at 3.0 T versus FDG PET/CT for detection of malignant pulmonary tumors.

    Science.gov (United States)

    Zhang, Jian; Cui, Long-Biao; Tang, Xing; Ren, Xin-Ling; Shi, Jie-Ran; Yang, Hai-Nan; Zhang, Yan; Li, Zhi-Kui; Wu, Chang-Gui; Jian, Wen; Zhao, Feng; Ti, Xin-Yu; Yin, Hong

    2014-02-01

    Emerging evidence suggests that diffusion-weighted magnetic resonance imaging (DW MRI) could be useful for tumor detection with N and M staging of lung cancer in place of fluorine 18 fluorodeoxyglucose positron emission tomography/computed tomography (FDG PET/CT). DW MRI at 3.0 T and FDG PET/CT were performed before therapy in 113 patients with pulmonary nodules. Mean apparent diffusion coefficient (ADC), maximal standardized uptake value (SUVmax ) and Ki-67 scores were assessed. Quantitatively, specificity and accuracy of ADC (91.7 and 92.9%, respectively) were significantly higher than those of SUVmax (66.7 and 77.9% respectively, p 0.05). Qualitatively, sensitivity, specificity and accuracy of DW MRI (96.1, 83.3 and 92.0%, respectively) were also not significantly different from that of FDG PET/CT (88.3, 83.3 and 86.7%, respectively, p > 0.05). Significant negative correlation was found between Ki-67 score and ADC (r = -0.66, p 0.05). In conclusion, quantitative and qualitative assessments for detection of malignant pulmonary tumors with DW MRI at 3.0 T are superior to those with FDG PET/CT. Furthermore, ADC could predict the malignancy of lung cancer. © 2013 UICC.

  20. Low-temperature H2-4He and H2-3He targets for operation on an electron beam

    International Nuclear Information System (INIS)

    Gol'dshtejn, V.A.; Lubyanyj, V.V.

    1981-01-01

    Structures and basic characteristics of H 2 - 4 He and H 2 - 3 He low temperature targets are given. Technique of 3 He target filling is described. Initial target cooling up to liquid 4 He temperature and its filling up take near approximately 1 h, at that 4 He flow rate equals 15 l. Repeated filling up of 4 He takes 20 min, and target filling up with 3 He - 10-15 min. Good thermal insulation of a cryostat and targets permits the 4 He target to be operated with an electron beam of a mean current of up to 0.5 μA without filling up 4 He for 70 h. At that flow rate of liquid 4 He amounts to 0.2 l/h, and liquid hydrogen - 0.04 l/h. It is concluded that H 2 - 4 He and H 2 - 3 He targets are reliable and simple in operation and permit to work with accelerated particle beams of intensity corresponding to power release >= 0.5 W without corrections for density change [ru

  1. Long-term follow-up of lung biodistribution and effect of instilled SWCNTs using multiscale imaging techniques

    International Nuclear Information System (INIS)

    Al Faraj, Achraf; Bessaad, Amine; Cieslar, Katarzyna; Canet-Soulas, Emmanuelle; Cremillieux, Yannick; Lacroix, Ghislaine

    2010-01-01

    Due to their distinctive properties, single-walled carbon nanotubes (SWCNTs) are being more and more extensively used in nanotechnology, with prospects in nanomedicine. It would therefore appear essential to develop and apply appropriate imaging tools for detecting and evaluating their biological impacts with the prospect of medical applications or in the situation of accidental occupational exposure. It has been shown recently that raw SWCNTs with metallic impurities can be noninvasively detected in the lungs by hyperpolarized 3 helium (HP- 3 He) MRI. Moreover raw and purified SWCNTs had no acute biological effect. The purpose of the present longitudinal study was to investigate long-term follow-up by imaging, as well as chronic lung effects. In a 3-month follow-up study, multiscale imaging techniques combining noninvasive HP- 3 He and proton (H) MRI to ex vivo light (histopathological analysis) and transmission electron microscopy (TEM) were used to assess the biodistribution and biological effects of intrapulmonary instilled raw SWCNTs. Specific in vivo detection of carbon nanotubes with MRI relied on their intrinsic metal impurities. MRI also has the ability to evaluate tissue inflammation by the follow-up of local changes in signal intensity. MRI and ex vivo microscopy techniques showed that granulomatous and inflammatory reactions were produced in a time and dose dependent manner by instilled raw SWCNTs.

  2. Probing HeII Reionization at z>3.5 with Resolved HeII Lyman Alpha Forest Spectra

    Science.gov (United States)

    Worseck, Gabor

    2017-08-01

    The advent of GALEX and COS have revolutionized our view of HeII reionization, the final major phase transition of the intergalactic medium. COS spectra of the HeII Lyman alpha forest have confirmed with high confidence the high HeII transmission that signifies the completion of HeII reionization at z 2.7. However, the handful of z>3.5 quasars observed to date show a set of HeII transmission 'spikes' and larger regions with non-zero transmission that suggest HeII reionization was well underway by z=4. This is in striking conflict with predictions from state-of-the-art radiative transfer simulations of a HeII reionization driven by bright quasars. Explaining these measurements may require either faint quasars or more exotic sources of hard photons at z>4, with concomitant implications for HI reionization. However, many of the observed spikes are unresolved in G140L spectra and are significantly impacted by Poisson noise. Current data cannot reliably probe the ionization state of helium at z>3.5.We request 41 orbits to obtain science-grade G130M spectra of the two UV-brightest HeII-transmitting QSOs at z>3.5 to confirm and resolve their HeII transmission spikes as an unequivocal test of early HeII reionization. These spectra are complemented by recently obtained data from 8m telescopes: (1) Echelle spectra of the coeval HI Lya forest to map the underlying density field that modulates the HeII absorption, and (2) Our dedicated survey for foreground QSOs that may source the HeII transmission. Our recent HST programs revealed the only two viable targets to resolve the z>3.5 HeII Lyman alpha forest, and to conclusively solve this riddle.

  3. A method for the accurate determination of the polarization of a neutron beam using a polarized 3He spin filter

    International Nuclear Information System (INIS)

    Greene, G.L.; Thompson, A.K.; Dewey, M.S.

    1995-01-01

    A new method for the accurate determination of the degree of polarization of a neutron beam which has been polarized by transmission through a spin polarized 3 He cell is given. The method does not require the use of an analyzer or spin flipper nor does it require an accurate independent determination of the 3 He polarization. The method provides a continuous on-line determination of the neutron polarization. The method may be of use in the accurate determination of correlation coefficients in neutron beta decay which provide a test of the standard model for the electroweak interaction. The method may also provide an accurate procedure for the calibration of polarized 3 He targets used in medium and high energy scattering experiments. ((orig.))

  4. Evaluation of heterogeneous metabolic profile in an orthotopic human glioblastoma xenograft model using compressed sensing hyperpolarized 3D 13C magnetic resonance spectroscopic imaging.

    Science.gov (United States)

    Park, Ilwoo; Hu, Simon; Bok, Robert; Ozawa, Tomoko; Ito, Motokazu; Mukherjee, Joydeep; Phillips, Joanna J; James, C David; Pieper, Russell O; Ronen, Sabrina M; Vigneron, Daniel B; Nelson, Sarah J

    2013-07-01

    High resolution compressed sensing hyperpolarized (13)C magnetic resonance spectroscopic imaging was applied in orthotopic human glioblastoma xenografts for quantitative assessment of spatial variations in (13)C metabolic profiles and comparison with histopathology. A new compressed sensing sampling design with a factor of 3.72 acceleration was implemented to enable a factor of 4 increase in spatial resolution. Compressed sensing 3D (13)C magnetic resonance spectroscopic imaging data were acquired from a phantom and 10 tumor-bearing rats following injection of hyperpolarized [1-(13)C]-pyruvate using a 3T scanner. The (13)C metabolic profiles were compared with hematoxylin and eosin staining and carbonic anhydrase 9 staining. The high-resolution compressed sensing (13)C magnetic resonance spectroscopic imaging data enabled the differentiation of distinct (13)C metabolite patterns within abnormal tissues with high specificity in similar scan times compared to the fully sampled method. The results from pathology confirmed the different characteristics of (13)C metabolic profiles between viable, non-necrotic, nonhypoxic tumor, and necrotic, hypoxic tissue. Copyright © 2012 Wiley Periodicals, Inc.

  5. The effect of Demkov coupling in the rotational predissociation of 3He4He+, ch. 4

    International Nuclear Information System (INIS)

    Asselt, N.P.F.B. van; Maas, J.G.; Los, J.

    1976-01-01

    The momentum distribution of the 3 He + and the 4 He + fragments, both originating from rotational predissociation of 3 He 4 He + has been measured. There is a pronounced difference between the intensity distributions in both spectra. This difference is explained as the result of a Demkov coupling between the two lowest electronic states of the molecular ion. The rotational quantum numbers of the states involved are calculated from the spectra

  6. CO2-, He- and H2-broadening coefficients of SO2 for ν1 band and ground state transitions for astrophysical applications

    Science.gov (United States)

    Ceselin, Giorgia; Tasinato, Nicola; Puzzarini, Cristina; Pietropolli Charmet, Andrea; Stoppa, Paolo; Giorgianni, Santi

    2017-12-01

    The discovery of the Universe and of the interstellar medium (ISM) is based on the knowledge of the molecules that are present in those places. Most of our understanding about the composition of the ISM and planetary atmospheres has been made possible almost entirely thanks to spectroscopic observations. Sulfur dioxide, SO2, is one of the about 200 molecules that have been detected in the ISM or circumstellar shells. In addition to its astrophysical relevance, SO2 has a proved role in the Earth's atmosphere. It origins from biomass burning and volcanic eruptions and directly enters in the sulfur cycle. In this work high-resolution tunable diode laser (TDL) infrared (IR) spectroscopy and mm-/sub-mm wave spectroscopy are exploited to retrieve the broadening parameters of sulfur dioxide perturbed by H2, He and CO2. IR measurements are carried out for ν1 band transitions around 9 μm by using He and CO2 as damping gases. As far as the vibrational ground state is concerned, about 20 rotational transitions are analyzed by means of the speed dependent Voigt profile to retrieve H2- and He-broadening coefficients. From the experimental results some conclusions about the quantum number dependence of the H2-, CO2- and He-collisional cross sections are drawn. Both IR and MW experiments highlight a very weak dependence of He broadening parameters on the Ka and J rotational quantum numbers. In a similar way, also SO2-H2 broadening coefficients show a negligible dependence on the rotational quantum numbers. Conversely, when CO2 is employed as perturbing species, the observed collisional cross sections tend to decrease with increasing Ka values and to increase against J, at least over the range of quantum numbers considered. The present results provide the first systematic determination of line-by-line SO2-CO2 broadening coefficients and they are of relevance to increase the potential use of spectroscopic databases for astronomical applications.

  7. Energy dependence and temporal evolution of the 3He/4He ratios in heavy-ion-rich energetic particle events

    International Nuclear Information System (INIS)

    Moebius, E.; Hovestadt, D.; Klecker, B.; Gloeckler, G.

    1980-01-01

    The energy dependence of the 3 He/ 4 He ratio between 0.44 and 4.1 MeV per nucleon has been studied for six heavy-ion--rich events observed in 1974 and 1976 using the low-energy dE/dx versus E Ultralow-Energy Particle telescope (ULET) on IMP 8. We find that all selected heavy-ion--rich events are also enriched in 3 He, that the 3 He/ 4 He He ratio decreases with decreasing energies, and that a rapid temporal evolution of the 3 He/ 4 He and the Fe/(H+He) ratios is strongly correlated during one event with the maximum value at the onset. These results are discussed in terms of a model which is based on preferential injection of 3 He and Fe resulting from turbulent ion heating and subsequent Fermi acceleration

  8. The production of He-3 and heavy ion enrichment in He-3-rich flares by electromagnetic hydrogen cyclotron waves

    Science.gov (United States)

    Temerin, M.; Roth, I.

    1992-01-01

    A new model is presented for the production of He-3 and heavy ion enrichments in He-3-rich flares using a direct single-stage mechanism. In analogy with the production of electromagnetic hydrogen cyclotron waves in earth's aurora by electron beams, it is suggested that such waves should exist in the electron acceleration region of impulsive solar flares. Both analytic and test-particle models of the effect of such waves in a nonuniform magnetic field show that these waves can selectively accelerate He-3 and heavy ions to MeV energies in a single-stage process, in contrast to other models which require a two-stage mechanism.

  9. Thermal convection and nonlinear effects of a superfluid 3He-4He mixture in a porous medium

    International Nuclear Information System (INIS)

    Chien, L.C.L.

    1986-01-01

    The convective instability of one-component classical fluids in a porous medium confined between two unbounded slabs was studied. This system behaves like a high Prandtl number bulk fluid. It has boundary conditions similar to the stress-free boundary conditions of bulk one-component classical fluids. Both the amplitude expansion method and the Galerkin method were used to investigate the nonlinear steady convection. Two dimensional rolls are the only stable motion at the onset of convection. Beyond threshold, the steady convection rolls become unstable to formation of cross-roll and zigzag instabilities. Applying the phase-dynamics approach for the zigzag instability, the author obtained the diffusion coefficient D, which can signal the onset of instability. Also investigated was the convective instability of superfluid 3 He- 4 He mixtures in porous media. Assuming no interaction between the average superflow and the porous medium and treating the normal flow in the equation of motion like a classical fluid in a porous medium, it was found that the superfluid mixtures in a porous medium. To investigate the effects of a lateral boundary, the convective instability of classical one-component fluids in porous media inside a box was studied. The zigzag instability does not exist because of the boundary conditions at the side of the box

  10. Lagrangian of superfluid 3He

    International Nuclear Information System (INIS)

    Theodorakis, S.

    1988-01-01

    This paper presents a phenomenological Lagrangian that fully describes the dynamics of any homogeneous phase of superfluid 3 He, unitary or not, omitting relaxation. This Lagrangian is built by using the concept of a local SO(3) x SO(3) x U(1) symmetry. The spin and angular momentum play the role of gauge fields. We derive the Leggett equations for spin and orbital dynamics from the equations of motion, for both the A and the B phase. This Lagrangian not only enables us to describe both the spin and orbital dynamics of superfluid 3 He in a unified fashion, but can also be used for finding the dynamics in any experimental situation. Furthermore, it can describe the dynamics of the magnitude, as well as of the orientation of the order parameter, and thus it can be used to describe the dynamics of the A-B phase transition

  11. The Cosmic Abundance of 3He: Green Bank Telescope Observations

    Science.gov (United States)

    Balser, Dana; Bania, Thomas

    2018-01-01

    The Big Bang theory for the origin of the Universe predicts that during the first ~1,000 seconds significant amounts of the light elements (2H, 3He, 4He, and 7Li) were produced. Many generations of stellar evolution in the Galaxy modifies these primordial abundances. Observations of the 3He+ hyperfine transition in Galactic HII regions reveals a 3He/H abundance ratio that is constant with Galactocentric radius to within the uncertainties, and is consistent with the primordial value as determined from cosmic microwave background experiments (e.g., WMAP). This "3He Plateau" indicates that the net production and destruction of 3He in stars is approximately zero. Recent stellar evolution models that include thermohaline mixing, however, predict that 3He/H abundance ratios should slightly decrease with Galactocentric radius, or in places in the Galaxy with lower star formation rates. Here we discuss sensitive Green Bank Telescope (GBT) observations of 3He+ at 3.46 cm in a subset of our HII region sample. We develop HII region models and derive accurate 3He/H abundance ratios to better constrain these new stellar evolution models.

  12. Transmit-Only/Receive-Only Radiofrequency System for Hyperpolarized 13C MRS Cardiac Metabolism Studies in Pigs

    DEFF Research Database (Denmark)

    Giovannetti, G.; Frijia, F.; Hartwig, V.

    2013-01-01

    Hyperpolarized 13C magnetic resonance spectroscopy in pig models enables metabolic activity mapping, providing a powerful tool for the study of the heart physiology, but requires the development of dedicated radiofrequency coils, capable of providing large field of view with high signal......-to-noise ratio (SNR) data. This work describes the simulations and the tests of a transmit-only (TX) volume coil/receive-only (RX) surface coil both designed for hyperpolarized studies of pig heart with a clinical 3T scanner. The coil characterization is performed by developing an SNR model for coil performance...

  13. Design of a 15N Molecular Unit to Achieve Long Retention of Hyperpolarized Spin State

    Science.gov (United States)

    Nonaka, Hiroshi; Hirano, Masashi; Imakura, Yuki; Takakusagi, Yoichi; Ichikawa, Kazuhiro; Sando, Shinsuke

    2017-01-01

    Nuclear hyperpolarization is a phenomenon that can be used to improve the sensitivity of magnetic resonance molecular sensors. However, such sensors typically suffer from short hyperpolarization lifetime. Herein we report that [15N, D14]trimethylphenylammonium (TMPA) has a remarkably long spin-lattice relaxation time (1128 s, 14.1 T, 30 °C, D2O) on its 15N nuclei and achieves a long retention of the hyperpolarized state. [15N, D14]TMPA-based hyperpolarized sensor for carboxylesterase allowed the highly sensitive analysis of enzymatic reaction by 15N NMR for over 40 min in phophate-buffered saline (H2O, pH 7.4, 37 °C).

  14. Modelling DW-MRI data from primary and metastatic ovarian tumours

    Energy Technology Data Exchange (ETDEWEB)

    Winfield, Jessica M. [Institute of Cancer Research, CRUK and EPSRC Cancer Imaging Centre, Division of Radiotherapy and Imaging, Surrey (United Kingdom); Royal Marsden NHS Foundation Trust, Surrey (United Kingdom); Institute of Cancer Research and Royal Marsden Hospital, MRI Unit, Surrey (United Kingdom); DeSouza, Nandita M.; Collins, David J. [Institute of Cancer Research, CRUK and EPSRC Cancer Imaging Centre, Division of Radiotherapy and Imaging, Surrey (United Kingdom); Royal Marsden NHS Foundation Trust, Surrey (United Kingdom); Priest, Andrew N.; Hodgkin, Charlotte; Freeman, Susan [University of Cambridge, Department of Radiology, Addenbrooke' s Hospital, Cambridge (United Kingdom); Wakefield, Jennifer C.; Orton, Matthew R. [Institute of Cancer Research, CRUK and EPSRC Cancer Imaging Centre, Division of Radiotherapy and Imaging, Surrey (United Kingdom)

    2015-07-15

    To assess goodness-of-fit and repeatability of mono-exponential, stretched exponential and bi-exponential models of diffusion-weighted MRI (DW-MRI) data in primary and metastatic ovarian cancer. Thirty-nine primary and metastatic lesions from thirty-one patients with stage III or IV ovarian cancer were examined before and after chemotherapy using DW-MRI with ten diffusion-weightings. The data were fitted with (a) a mono-exponential model to give the apparent diffusion coefficient (ADC), (b) a stretched exponential model to give the distributed diffusion coefficient (DDC) and stretching parameter (α), and (c) a bi-exponential model to give the diffusion coefficient (D), perfusion fraction (f) and pseudodiffusion coefficient (D*). Coefficients of variation, established from repeated baseline measurements, were: ADC 3.1 %, DDC 4.3 %, α 7.0 %, D 13.2 %, f 44.0 %, D* 165.1 %. The bi-exponential model was unsuitable in these data owing to poor repeatability. After excluding the bi-exponential model, analysis using Akaike Information Criteria showed that the stretched exponential model provided the better fit to the majority of pixels in 64 % of lesions. The stretched exponential model provides the optimal fit to DW-MRI data from ovarian, omental and peritoneal lesions and lymph nodes in pre-treatment and post-treatment measurements with good repeatability. (orig.)

  15. Lung MRI for experimental drug research

    International Nuclear Information System (INIS)

    Beckmann, Nicolau; Cannet, Catherine; Karmouty-Quintana, Harry; Tigani, Bruno; Zurbruegg, Stefan; Ble, Francois-Xavier; Cremillieux, Yannick; Trifilieff, Alexandre

    2007-01-01

    Current techniques to evaluate the efficacy of potential treatments for airways diseases in preclinical models are generally invasive and terminal. In the past few years, the flexibility of magnetic resonance imaging (MRI) to obtain anatomical and functional information of the lung has been explored with the scope of developing a non-invasive approach for the routine testing of drugs in models of airways diseases in small rodents. With MRI, the disease progression can be followed in the same animal. Thus, a significant reduction in the number of animals used for experimentation is achieved, as well as minimal interference with their well-being and physiological status. In addition, under certain circumstances the duration of the observation period after disease onset can be shortened since the technique is able to detect changes before these are reflected in parameters of inflammation determined using invasive procedures. The objective of this article is to briefly address MRI techniques that are being used in experimental lung research, with special emphasis on applications. Following an introduction on proton techniques and MRI of hyperpolarized gases, the attention is shifted to the MRI analysis of several aspects of lung disease models, including inflammation, ventilation, emphysema, fibrosis and sensory nerve activation. The next subject concerns the use of MRI in pharmacological studies within the context of experimental lung research. A final discussion points towards advantages and limitations of MRI in this area

  16. Calculations of static properties of spin-polarized 3He--4He mixtures

    International Nuclear Information System (INIS)

    Owers-Bradley, J.R.; Bowley, R.M.; Main, P.C.

    1985-01-01

    The theory of dilute mixtures of 3 He in 4 He that have been polarized by a strong magnetic field is developed. The interaction between the quasiparticles is taken to be constant, an approximation valid at low temperatures. The polarization of the mixture depends on the strength of the interaction. The internal energy, the specific heat, the osmotic pressure, and the velocity of second sound are also calculated. The specific heat is relatively insensitive to the interaction, but it does change significantly with magnetic field. The osmotic pressure is more sensitive to the effects of the interaction for some 3 He concentrations and temperatures. The velocity of second sound behaves qualitatively like the osmotic pressure. The measurement of these quantities as a function of temperature and magnetic field is discussed with a view to obtaining the strength of the interaction between quasiparticles

  17. Diagnosis of rotator cuff tears using 3-Tesla MRI versus 3-Tesla MRA: a systematic review and meta-analysis

    Energy Technology Data Exchange (ETDEWEB)

    McGarvey, Ciaran; Harb, Ziad; Smith, Christian; Ajuied, Adil [Guy' s and St Thomas' Hospital, King' s Health Partners, Department of Trauma and Orthopaedics, London (United Kingdom); Houghton, Russell [Guy' s and St Thomas' Hospital, King' s Health Partners, Department of Radiology, London (United Kingdom); Corbett, Steven [Guy' s and St Thomas' Hospital, King' s Health Partners, Department of Trauma and Orthopaedics, London (United Kingdom); Fortius Clinic, London (United Kingdom)

    2016-02-15

    To compare the diagnostic accuracy of magnetic resonance imaging (MRI), 2-dimensional magnetic resonance arthrogram (MRA) and 3-dimensional isotropic MRA in the diagnosis of rotator cuff tears when performed exclusively at 3-T. A systematic review was undertaken of the Cochrane, MEDLINE and PubMed databases in accordance with the PRISMA guidelines. Studies comparing 3-T MRI or 3-T MRA (index tests) to arthroscopic surgical findings (reference test) were included. Methodological appraisal was performed using QUADAS 2. Pooled sensitivity and specificity were calculated and summary receiver-operating curves generated. Kappa coefficients quantified inter-observer reliability. Fourteen studies comprising 1332 patients were identified for inclusion. Twelve studies were retrospective and there were concerns regarding index test bias and applicability in nine and six studies respectively. Reference test bias was a concern in all studies. Both 3-T MRI and 3-T MRA showed similar excellent diagnostic accuracy for full-thickness supraspinatus tears. Concerning partial-thickness supraspinatus tears, 3-T 2D MRA was significantly more sensitive (86.6 vs. 80.5 %, p = 0.014) but significantly less specific (95.2 vs. 100 %, p < 0.001). There was a trend towards greater accuracy in the diagnosis of subscapularis tears with 3-T MRA. Three-Tesla 3D isotropic MRA showed similar accuracy to 3-T conventional 2D MRA. Three-Tesla MRI appeared equivalent to 3-T MRA in the diagnosis of full- and partial-thickness tears, although there was a trend towards greater accuracy in the diagnosis of subscapularis tears with 3-T MRA. Three-Tesla 3D isotropic MRA appears equivalent to 3-T 2D MRA for all types of tears. (orig.)

  18. Diagnosis of rotator cuff tears using 3-Tesla MRI versus 3-Tesla MRA: a systematic review and meta-analysis

    International Nuclear Information System (INIS)

    McGarvey, Ciaran; Harb, Ziad; Smith, Christian; Ajuied, Adil; Houghton, Russell; Corbett, Steven

    2016-01-01

    To compare the diagnostic accuracy of magnetic resonance imaging (MRI), 2-dimensional magnetic resonance arthrogram (MRA) and 3-dimensional isotropic MRA in the diagnosis of rotator cuff tears when performed exclusively at 3-T. A systematic review was undertaken of the Cochrane, MEDLINE and PubMed databases in accordance with the PRISMA guidelines. Studies comparing 3-T MRI or 3-T MRA (index tests) to arthroscopic surgical findings (reference test) were included. Methodological appraisal was performed using QUADAS 2. Pooled sensitivity and specificity were calculated and summary receiver-operating curves generated. Kappa coefficients quantified inter-observer reliability. Fourteen studies comprising 1332 patients were identified for inclusion. Twelve studies were retrospective and there were concerns regarding index test bias and applicability in nine and six studies respectively. Reference test bias was a concern in all studies. Both 3-T MRI and 3-T MRA showed similar excellent diagnostic accuracy for full-thickness supraspinatus tears. Concerning partial-thickness supraspinatus tears, 3-T 2D MRA was significantly more sensitive (86.6 vs. 80.5 %, p = 0.014) but significantly less specific (95.2 vs. 100 %, p < 0.001). There was a trend towards greater accuracy in the diagnosis of subscapularis tears with 3-T MRA. Three-Tesla 3D isotropic MRA showed similar accuracy to 3-T conventional 2D MRA. Three-Tesla MRI appeared equivalent to 3-T MRA in the diagnosis of full- and partial-thickness tears, although there was a trend towards greater accuracy in the diagnosis of subscapularis tears with 3-T MRA. Three-Tesla 3D isotropic MRA appears equivalent to 3-T 2D MRA for all types of tears. (orig.)

  19. Simulated radiographic bone and joint modeling from 3D ankle MRI: feasibility and comparison with radiographs and 2D MRI

    Energy Technology Data Exchange (ETDEWEB)

    Nordeck, Shaun M. [University of Texas Southwestern Medical College, Dallas, TX (United States); University of Texas Southwestern Medical Center, Musculoskeletal Radiology, Dallas, TX (United States); Koerper, Conrad E.; Adler, Aaron [University of Texas Southwestern Medical College, Dallas, TX (United States); Malhotra, Vidur; Xi, Yin [University of Texas Southwestern Medical Center, Musculoskeletal Radiology, Dallas, TX (United States); Liu, George T. [University of Texas Southwestern Medical Center, Orthopaedic Surgery, Dallas, TX (United States); Chhabra, Avneesh [University of Texas Southwestern Medical Center, Musculoskeletal Radiology, Dallas, TX (United States); University of Texas Southwestern Medical Center, Orthopaedic Surgery, Dallas, TX (United States)

    2017-05-15

    The purpose of this work is to simulate radiographs from isotropic 3D MRI data, compare relationship of angle and joint space measurements on simulated radiographs with corresponding 2D MRIs and real radiographs (XR), and compare measurement times among the three modalities. Twenty-four consecutive ankles were included, eight males and 16 females, with a mean age of 46 years. Segmented joint models simulating radiographs were created from 3D MRI data sets. Three readers independently performed blinded angle and joint space measurements on the models, corresponding 2D MRIs, and XRs at two time points. Linear mixed models and the intraclass correlation coefficient (ICC) was ascertained, with p values less than 0.05 considered significant. Simulated radiograph models were successfully created in all cases. Good agreement (ICC > 0.65) was noted among all readers across all modalities and among most measurements. Absolute measurement values differed between modalities. Measurement time was significantly greater (p < 0.05) on 2D versus simulated radiographs for most measurements and on XR versus simulated radiographs (p < 0.05) for nearly half the measurements. Simulated radiographs can be successfully generated from 3D MRI data; however, measurements differ. Good inter-reader and moderate-to-good intra-reader reliability was observed and measurements obtained on simulated radiograph models took significantly less time compared to measurements with 2D and generally less time than XR. (orig.)

  20. (3He,α) reaction mechanism at high energy and neutron inner shell structure

    International Nuclear Information System (INIS)

    Wiele, J. van de.

    1980-01-01

    The ( 3 He,α) reaction on 12 C, 16 O, 28 Si, 58 Ni, 90 Zr, 118 Sn, 124 Sn and 208 Pb targets has been studied at Esub( 3 He) = 217 MeV (or 205 MeV) in order to investigate the reaction mechanism at high energy and large momentum transfer. The reaction yields large cross sections at very forward angles and strongly enhances the largest orbital momentum transfer. The angular distribution shapes are well reproduced in the frame-work of the Z-R- D.W.B.A. analysis if we use a unique empirical α-potential: Vsub(α)(Esub(α)) = Vsub( 3 He)(3/4 Esub(α)) + Vsub(n)(1/4 Esub(α)). The excitation energy spectra have been measured up to 100 MeV in the residual light and medium nuclei and up to about 16 MeV in heavy nuclei. In addition to the well-known low-lying levels, peaks or broad structures are observed for each nucleus at higher excitation energies. They are attributed to pick up from inner shells: 1s( 11 C and 15 O), 1p( 27 Si), 1d5/2 + 1p( 57 Ni), 1f7/2( 89 Zr) 1g9/2 117 Sn, 123 Sn and 1h11/2( 207 Pb). Selectivity and localization of direct and indirect pick up ( 3 He,α) reactions were studied. Finite range calculations show that this reaction is not very sensitive to the details of the range from function but only to D 0 coefficient and range R. A microscopic α-nucleus optical potential calculated with n-n dependent and independent density forces is able to reproduce both elastic scattering and pick up reaction angular distributions [fr

  1. On the 3He anomaly in hot subdwarf B stars

    Science.gov (United States)

    Schneider, David; Irrgang, Andreas; Heber, Ulrich; Nieva, Maria F.; Przybilla, Norbert

    2017-12-01

    Decades ago, 3He isotope enrichment in helium-weak B-type main-sequence, in blue horizontal branch and in hot subdwarf B (sdB) stars, i.e., helium-core burning stars of the extreme horizontal branch, were discovered. Diffusion processes in the atmosphere of these stars lead to the observed abundance anomalies. Quantitative spectral analyses of high-resolution spectra to derive photospheric isotopic helium abundance ratios for known 3He sdBs have not been performed yet. We present preliminary results of high-resolution and high S/N spectra to determine the 3He and 4He abundances of nine known 3He sdBs. We used a hybrid local/non-local thermodynamic equilibrium (LTE/NLTE) approach for B-type stars investigating multiple He i lines, including λ4922 Å and λ6678 Å, which show the strongest isotopic shifts in the optical spectral range.We also report the discovery of four new 3He sdBs from the ESO Supernova Progenitor survey. Most of the 3He sdBs cluster in a narrow temperature strip between ˜ 26000 K and ˜ 30000 K and have almost no atmospheric 4He at all. Interestingly, three 3He sdBs show evidence for vertical helium stratification.

  2. On the 3He anomaly in hot subdwarf B stars

    Directory of Open Access Journals (Sweden)

    Schneider David

    2017-12-01

    Full Text Available Decades ago, 3He isotope enrichment in helium-weak B-type main-sequence, in blue horizontal branch and in hot subdwarf B (sdB stars, i.e., helium-core burning stars of the extreme horizontal branch, were discovered. Diffusion processes in the atmosphere of these stars lead to the observed abundance anomalies. Quantitative spectral analyses of high-resolution spectra to derive photospheric isotopic helium abundance ratios for known 3He sdBs have not been performed yet. We present preliminary results of high-resolution and high S/N spectra to determine the 3He and 4He abundances of nine known 3He sdBs. We used a hybrid local/non-local thermodynamic equilibrium (LTE/NLTE approach for B-type stars investigating multiple He i lines, including λ4922 Å and λ6678 Å, which show the strongest isotopic shifts in the optical spectral range.We also report the discovery of four new 3He sdBs from the ESO Supernova Progenitor survey. Most of the 3He sdBs cluster in a narrow temperature strip between ∼ 26000 K and ∼ 30000 K and have almost no atmospheric 4He at all. Interestingly, three 3He sdBs show evidence for vertical helium stratification.

  3. Reduction in 14 MeV neutron generation rate by ICRF injection in D-3He burning plasmas

    International Nuclear Information System (INIS)

    Matsuura, Hideaki; Nakao, Yasuyuki

    2004-01-01

    The triton distribution function during ion cyclotron range of frequency (ICRF) waves injection in D- 3 He plasmas is examined by solving the 2-dimensional Fokker-Planck equation. Triton distribution function originally has a non-Maxwellian (tail) component around 1.01 MeV birth energy range due to D(d,p)T fusion reaction. Owing to the extension of the original tail by ICRF injection, the high-energy resonance tritons further increase, and the velocity-averaged T(d,n) 4 He fusion reaction rate coefficient, i.e. 14 MeV neutron generation rate, decreases from the values when triton is assumed to be Maxwellian. It is shown that when tritons absorb ∼1/200 of the fusion power from the waves in typical D- 3 He plasma, i.e. T=80 keV, n D =2x10 20 m -3 , τ E0 =3 sec and B=6T, the 14 MeV neutron generation rate is reduced by about ∼20% from the values for Maxwellian plasmas. (author)

  4. Hyperpolarized Water Perfusion in the Porcine Brain – a Pilot Study

    DEFF Research Database (Denmark)

    Søvsø Szocska Hansen, Esben; Lipsø, Hans Kasper Wigh; Tougaard, Rasmus Stilling

    2017-01-01

    Dynamic Contrast-Enhanced MR (DCE-MR) perfusion assessment with gadolinium contrast agents is currently the most widely used cerebral perfusion MR method. Hyperpolarized water has recently been shown to succeed 13C probes as angiography probe. In this study, we demonstrate the feasibility...... of hyperpolarized water for visualizing the brain vasculature of a large animal in a clinically relevant setting. In detail, reference perfusion values were obtained and large to small arteries could be identified....

  5. /sup 3/He functions in tokamak-pumped laser systems

    Energy Technology Data Exchange (ETDEWEB)

    Jassby, D.L.

    1986-10-01

    /sup 3/He placed in an annular cell around a tokamak fusion generator can convert moderated fusion neutrons to energetic ions by the /sup 3/He(n,p)T reaction, and thereby excite gaseous lasants mixed with the /sup 3/He while simultaneously breeding tritium. The total /sup 3/He inventory is about 4 kg for large tokamak devices. Special configurations of toroidal-field magnets, neutron moderators and beryllium reflectors are required to permit nearly uniform neutron current into the laser cell with minimal attenuation. The annular laser radiation can be combined into a single output beam at the top of the tokamak.

  6. The new phases of liquid 3He

    International Nuclear Information System (INIS)

    Leggett, A.J.

    1976-01-01

    Comments are made on two new phases of liquid 3 He, referred to as 3 He-A and 3 He-B, discovered in the temperature region below 3 mk. It has been assumed that these new phases are anisotropic superfluids, and a general picture of them is presented, which has been successful in explaining at least qualitatively, many of the static, dynamic and transport properties of the new phases. Whilst the qualitative behaviour is in good agreement with theory there are, however, some quantitative discrepancies. In many cases these may be due to orientational and geometric effects not yet understood. One of the most fruitful areas for comparison of theory and experiment is the NMR behaviour and the dynamic nuclear magnetism. The anomalous behaviour observed arises because the nuclear dipole energy, although very small, can act coherently in the superfluid state. (U.K.)

  7. Apparent diffusion coefficient measurements of bilateral kidneys at 3 T MRI: Effects of age, gender, and laterality in healthy adults

    International Nuclear Information System (INIS)

    Suo, S.-T.; Cao, M.-Q.; Ding, Y.-Z.; Yao, Q.-Y.; Wu, G.-Y.; Xu, J.-R.

    2014-01-01

    Aim: To investigate the effects of age and gender on apparent diffusion coefficient (ADC) measurements of bilateral kidneys at 3 T MRI, and compare the ADC values of left and right kidneys. Materials and methods: In all, 137 healthy participants (mean age 42.8 ± 14.7 years; age range 16–75 years) comprising 68 male and 69 female participants were enrolled. Three Tesla echo-planar diffusion-weighted imaging (DWI) of bilateral kidneys was performed and ADC values were measured in the cortex, medulla, and whole parenchyma. Pearson correlation analysis and linear regression were performed to determine the associations between the ADC values in each region and age. Effects of age and gender on ADC values were analysed using two-factor analysis of variance (ANOVA). The paired-samples t-test was established to compare the ADC values between left and right kidneys. Results: ADC values were significantly higher in the young group (≤50 years) than in the old group (>50 years), and correlated inversely with the age in all regions. Male participants had higher ADC values than female participants in all regions except left medulla. Two-factor ANOVA of age × gender showed no significant interactions between the variables age and gender were found. No significant differences in ADC values between left and right kidneys were observed. Conclusion: Renal ADC values are age- and gender-dependent, and show no significant difference between left and right kidneys. Age- and gender-related effects should be taken into consideration in future renal DWI studies when using normal ADC values from health controls. - Highlights: • Renal apparent diffusion coefficient (ADC) values decrease with ageing. • Men tend to have higher renal ADC values than women. • Bilateral kidneys seem to have no significantly different ADC values

  8. MRI of 'brain death'

    International Nuclear Information System (INIS)

    Nishino, Shigeki; Itoh, Takahiko; Tuchida, Shohei; Kinugasa, Kazushi; Asari, Shoji; Nishimoto, Akira; Sanou, Kazuo.

    1990-01-01

    Magnetic resonance imaging (MRI) was undertaken for two patients who suffered from severe cerebrovascular diseases and were clinically brain dead. The MRI system we used was Resona (Yokogawa Medical Systems, superconductive system 0.5 T) and the CT apparatus was Toshiba TCT-300. Initial CT and MRI were undertaken as soon as possible after admission, and repeated sequentially. After diagnosis of brain death, we performed angiography to determine cerebral circulatory arrest, and MRI obtained at the same time was compared with the angiogram and CT. Case 1 was a 77-year-old man who was admitted in an unconscious state. CT and MRI on the second day after hospitalization revealed cerebellar infarction. He was diagnosed as brain dead on day 4. Case 2 was a 35-year-old man. When he was transferred to our hospital, he was in cardiorespiratory arrested. Cardiac resuscitation was successful but no spontaneous respiration appeared. CT and MRI on admission revealed right intracerebral hemorrhage. Angiography revealed cessation of contrast medium in intracranial vessels in both of the patients. We found no 'flow signal void sign' in the bilateral internal carotid and basilar arteries on MRI images in both cases after brain death. MRI, showing us the anatomical changes of the brain, clearly revealed brain herniations, even though only nuclear findings of 'brain tamponade' were seen on CT. But in Case 1, we could not see the infarct lesions in the cerebellum on MR images obtained after brain death. This phenomenon was caused by the whole brain ischemia masking the initial ischemic lesions. We concluded that MRI was useful not only the anatomical display of lesions and brain herniation with high contrast resolution but for obtaining information on cerebral circulation of brain death. (author)

  9. Metabolic Imaging of Patients with Prostate Cancer Using Hyperpolarized [1-13C]Pyruvate

    Science.gov (United States)

    Nelson, Sarah J.; Kurhanewicz, John; Vigneron, Daniel B.; Larson, Peder E. Z.; Harzstark, Andrea L.; Ferrone, Marcus; van Criekinge, Mark; Chang, Jose W.; Bok, Robert; Park, Ilwoo; Reed, Galen; Carvajal, Lucas; Small, Eric J.; Munster, Pamela; Weinberg, Vivian K.; Ardenkjaer-Larsen, Jan Henrik; Chen, Albert P.; Hurd, Ralph E.; Odegardstuen, Liv-Ingrid; Robb, Fraser J.; Tropp, James; Murray, Jonathan A.

    2014-01-01

    This first-in-man imaging study evaluated the safety and feasibility of hyperpolarized [1-13C]pyruvate as an agent for noninvasively characterizing alterations in tumor metabolism for patients with prostate cancer. Imaging living systems with hyperpolarized agents can result in more than 10,000-fold enhancement in signal relative to conventional magnetic resonance (MR) imaging. When combined with the rapid acquisition of in vivo 13C MR data, it is possible to evaluate the distribution of agents such as [1-13C]pyruvate and its metabolic products lactate, alanine, and bicarbonate in a matter of seconds. Preclinical studies in cancer models have detected elevated levels of hyperpolarized [1-13C]lactate in tumor, with the ratio of [1-13C]lactate/[1-13C]pyruvate being increased in high-grade tumors and decreased after successful treatment. Translation of this technology into humans was achieved by modifying the instrument that generates the hyperpolarized agent, constructing specialized radio frequency coils to detect 13C nuclei, and developing new pulse sequences to efficiently capture the signal. The study population comprised patients with biopsy-proven prostate cancer, with 31 subjects being injected with hyperpolarized [1-13C]pyruvate. The median time to deliver the agent was 66 s, and uptake was observed about 20 s after injection. No dose-limiting toxicities were observed, and the highest dose (0.43 ml/kg of 230 mM agent) gave the best signal-to-noise ratio for hyperpolarized [1-13C]pyruvate. The results were extremely promising in not only confirming the safety of the agent but also showing elevated [1-13C]lactate/[1-13C]pyruvate in regions of biopsy-proven cancer. These findings will be valuable for noninvasive cancer diagnosis and treatment monitoring in future clinical trials. PMID:23946197

  10. Observation of flow dissipation in 3He-B

    International Nuclear Information System (INIS)

    Eisenstein, J.P.; Packard, R.E.

    1982-01-01

    Anomalous dissipation is observed in 3 He-B flowing in a U-tube device. The dissipation is of unknown origin and persists to the lowest measured velocity. The position of this result in the framework of other 3 He-B flow experiments is discussed

  11. Functional MRI of the patellofemoral joint: comparison of ultrafast MRI, motion-triggered cine MRI and static MRI

    Energy Technology Data Exchange (ETDEWEB)

    Muhle, C. [Klinik fuer Radiologische Diagnostik, Univ. Kiel (Germany); Brossmann, J. [Klinik fuer Radiologische Diagnostik, Univ. Kiel (Germany); Melchert, U.H. [Klinik fuer Radiologische Diagnostik, Univ. Kiel (Germany); Schroeder, C. [Radiologische Abt., Universitaets-Kinderklinik, Christian-Albrechts-Universitaet, Kiel (Germany); Boer, R. de [Philips Medical Systems, Best (Netherlands); Spielmann, R.P. [Klinik fuer Radiologische Diagnostik, Univ. Kiel (Germany); Heller, M. [Klinik fuer Radiologische Diagnostik, Univ. Kiel (Germany)

    1995-12-31

    To evaluate the feasibility and usefulness of ultrafast MRI (u), patellar tracking from 30 of flexion to knee extension (0 ) was analysed and compared with motion-triggered cine MRI (m) and a static MRI technique (s). The different imaging methods were compared in respect of the patellofemoral relationship, the examination time and image quality. Eight healthy subjects and four patients (in total 18 joints) with patellar subluxation or luxation were examined. Significant differences between the static MRI series without quadriceps contraction and the functional MRI studies (motion-triggered cine MRI and ultrafast MRI) were found for the patellar tilt angle. In the dynamic joint studies there was no statistical difference of the regression coefficients between the motion-triggered cine MRI studies and the ultrafast MRI studies. The findings of the functional MRI studies compared with the static MRI images were significantly different for the lateralisation of the patella, expressed by the lateral patellar displacement and bisect offset. No significant differences in patellar lateralisation were found between motion-triggered cine MRI and ultrafast MRI. Ultrafast MRI was superior to motion-triggered cine MRI in terms of the reduction in imaging time and improvement of the image quality. (orig.)

  12. Functional MRI of the patellofemoral joint: comparison of ultrafast MRI, motion-triggered cine MRI and static MRI

    International Nuclear Information System (INIS)

    Muhle, C.; Brossmann, J.; Melchert, U.H.; Schroeder, C.; Boer, R. de; Spielmann, R.P.; Heller, M.

    1995-01-01

    To evaluate the feasibility and usefulness of ultrafast MRI (u), patellar tracking from 30 of flexion to knee extension (0 ) was analysed and compared with motion-triggered cine MRI (m) and a static MRI technique (s). The different imaging methods were compared in respect of the patellofemoral relationship, the examination time and image quality. Eight healthy subjects and four patients (in total 18 joints) with patellar subluxation or luxation were examined. Significant differences between the static MRI series without quadriceps contraction and the functional MRI studies (motion-triggered cine MRI and ultrafast MRI) were found for the patellar tilt angle. In the dynamic joint studies there was no statistical difference of the regression coefficients between the motion-triggered cine MRI studies and the ultrafast MRI studies. The findings of the functional MRI studies compared with the static MRI images were significantly different for the lateralisation of the patella, expressed by the lateral patellar displacement and bisect offset. No significant differences in patellar lateralisation were found between motion-triggered cine MRI and ultrafast MRI. Ultrafast MRI was superior to motion-triggered cine MRI in terms of the reduction in imaging time and improvement of the image quality. (orig.)

  13. Capture of ions by vortex lines in pure 4He and 3He--4He solutions

    International Nuclear Information System (INIS)

    Ostermeier, R.M.; Glaberson, W.I.

    1975-01-01

    Measurements of the capture cross section for the negative ion by vortex lines in pure 4 He and a 0.94 percent solution of 3 He in 4 He are presented. A measurable capture of positive ions was not observed in either system. In pure 4 He the departure of the experimental data from the predictions of stochastic theory at lower temperatures is explained in terms of a simple breakdown in that theory, and lifetime effects are shown to be of only secondary importance. The decrease in cross section with decreasing temperature, due essentially to a reduced number density of rotons, is predicted by the results of a Monte Carlo calculation. The cross section in the solution follows stochastic theory to significantly lower temperatures, but at about 1 K there again occurs a marked discrepancy. Measurements of the ion trapping lifetime at low temperatures indicate that it is the finite lifetime that accounts for this discrepancy. Elimination of lifetime effects results in fair agreement between the cross section data in the solution and the predictions of stochastic theory. (11 figures) (auth)

  14. Technique development of 3D dynamic CS-EPSI for hyperpolarized 13 C pyruvate MR molecular imaging of human prostate cancer.

    Science.gov (United States)

    Chen, Hsin-Yu; Larson, Peder E Z; Gordon, Jeremy W; Bok, Robert A; Ferrone, Marcus; van Criekinge, Mark; Carvajal, Lucas; Cao, Peng; Pauly, John M; Kerr, Adam B; Park, Ilwoo; Slater, James B; Nelson, Sarah J; Munster, Pamela N; Aggarwal, Rahul; Kurhanewicz, John; Vigneron, Daniel B

    2018-03-25

    The purpose of this study was to develop a new 3D dynamic carbon-13 compressed sensing echoplanar spectroscopic imaging (EPSI) MR sequence and test it in phantoms, animal models, and then in prostate cancer patients to image the metabolic conversion of hyperpolarized [1- 13 C]pyruvate to [1- 13 C]lactate with whole gland coverage at high spatial and temporal resolution. A 3D dynamic compressed sensing (CS)-EPSI sequence with spectral-spatial excitation was designed to meet the required spatial coverage, time and spatial resolution, and RF limitations of the 3T MR scanner for its clinical translation for prostate cancer patient imaging. After phantom testing, animal studies were performed in rats and transgenic mice with prostate cancers. For patient studies, a GE SPINlab polarizer (GE Healthcare, Waukesha, WI) was used to produce hyperpolarized sterile GMP [1- 13 C]pyruvate. 3D dynamic 13 C CS-EPSI data were acquired starting 5 s after injection throughout the gland with a spatial resolution of 0.5 cm 3 , 18 time frames, 2-s temporal resolution, and 36 s total acquisition time. Through preclinical testing, the 3D CS-EPSI sequence developed in this project was shown to provide the desired spectral, temporal, and spatial 5D HP 13 C MR data. In human studies, the 3D dynamic HP CS-EPSI approach provided first-ever simultaneously volumetric and dynamic images of the LDH-catalyzed conversion of [1- 13 C]pyruvate to [1- 13 C]lactate in a biopsy-proven prostate cancer patient with full gland coverage. The results demonstrate the feasibility to characterize prostate cancer metabolism in animals, and now patients using this new 3D dynamic HP MR technique to measure k PL , the kinetic rate constant of [1- 13 C]pyruvate to [1- 13 C]lactate conversion. © 2018 International Society for Magnetic Resonance in Medicine.

  15. Synthesis of new host molecules and applications for imaging by NMR Xe

    International Nuclear Information System (INIS)

    Traore, T.

    2011-01-01

    Magnetic Resonance Imaging (MRI) is widely used today for early medical diagnosis. During the MRI examination, the use of contrast agent allows the obtention of well resolved images. However the lack of sensibility of this technic lead to the utilization of hyper-polarized species ( 3 He, 13 C, 129 Xe) in MRI. The xenon (Xe) is the more promising but due to its weak selectivity, it cannot be used in molecular imaging. So, the development and utilization of host molecules able to encapsulate the xenon and bring it to a targeted biological tissue or organ is necessary. In these conditions, during this thesis, we worked on the elaboration of such molecules, and particularly, in cryptophanes since these compounds have strong affinity for xenon and could be used as tools for MRI by hyper-polarized xenon (Hp Xe). A new route synthesis of cryptophane-111, that has the highest affinity for xenon, was developed; first functionalized derivatives of this compound have been also obtained in order to obtain the first biosensors based on cryptophane-111. The coating of specific ligand on these functionalized compounds could allow targeted MRI. A probe for hydrogen peroxide (H 2 O 2 ) detection was synthesized. Hydrogen peroxide is implicated in cellular oxidative stress and present in case of neuro-degenerative diseases (Parkinson, Alzheimer). The probe obtained allowed the imaging of H 2 O 2 by MRI Xe for the first time. nano-tubes functionalized with strong concentration of cryptophane have been synthesized in order to increase the sensitivity of the imaging technic that uses xenon. (author) [fr

  16. Continuous hyperpolarization with parahydrogen in a membrane reactor

    Science.gov (United States)

    Lehmkuhl, Sören; Wiese, Martin; Schubert, Lukas; Held, Mathias; Küppers, Markus; Wessling, Matthias; Blümich, Bernhard

    2018-06-01

    Hyperpolarization methods entail a high potential to boost the sensitivity of NMR. Even though the "Signal Amplification by Reversible Exchange" (SABRE) approach uses para-enriched hydrogen, p-H2, to repeatedly achieve high polarization levels on target molecules without altering their chemical structure, such studies are often limited to batch experiments in NMR tubes. Alternatively, this work introduces a continuous flow setup including a membrane reactor for the p-H2, supply and consecutive detection in a 1 T NMR spectrometer. Two SABRE substrates pyridine and nicotinamide were hyperpolarized, and more than 1000-fold signal enhancement was found. Our strategy combines low-field NMR spectrometry and a membrane flow reactor. This enables precise control of the experimental conditions such as liquid and gas pressures, and volume flow for ensuring repeatable maximum polarization.

  17. Metabolic imaging of patients with prostate cancer using hyperpolarized [1-¹³C]pyruvate

    DEFF Research Database (Denmark)

    Nelson, Sarah J; Kurhanewicz, John; Vigneron, Daniel B

    2013-01-01

    This first-in-man imaging study evaluated the safety and feasibility of hyperpolarized [1-¹³C]pyruvate as an agent for noninvasively characterizing alterations in tumor metabolism for patients with prostate cancer. Imaging living systems with hyperpolarized agents can result in more than 10,000-f...

  18. Ab initio study of small He cluster ions Hen+, n=2, 3, 4, 5, and low-lying Rydberg states of He4

    International Nuclear Information System (INIS)

    Staemmler, V.

    1990-01-01

    SCF and CEPA calculations are applied to study the structure of small He cluster ions, He n 3 , n=2, 3, 4, 5 and some low-lying Rydberg states of He 4 . The effect of electron correlation upon the equilibrium structures and binding energies is discussed. He 3 + has a linear symmetric equilibrium geometry with a bond length of 2.35 a 0 and a binding energy D e =0.165 eV with respect to He 2 + +He (experimentally: D 0 =0.17 eV which corresponds to D e ≅0.20 eV). He 4 + is a very floppy molecular ion with several energetically very similar geometrical configurations. Our CEPA calculations yield a T-shaped form with a He 3 + centre (R e =2.35 a 0 ) and one inductively bound He atom (4.39 a 0 from the central He atom of He 3 + ) as equilibrium structure. Its binding energy with respect to He 3 + +He is 0.031 eV. A linear symmetric configuration consisting of a He 2 + centre with a bond length of 2.10 a 0 and two inductively bound He atoms (4.20 a 0 from the centre of He 2 + ) is only 0.02-0.03 eV higher in energy. We expect that in larger He cluster ions structures with He 2 + and He 3 + centres and n-2 or n-3 inductively bound He atoms have nearly the same energies. In He 4 a low-lying metastable Rydberg state ( 3 π symmetry for linear He 4 * , 3 B 1 for the T-shaped form) exists which is slightly stronger bound with respect to He 3 * +He than the corresponding ion. (orig.)

  19. 3He/4He production ratios by tetrahedral symmetric condensation

    International Nuclear Information System (INIS)

    Takahashi, Akito

    2006-01-01

    The present paper treats application of the Electronic Quasi-Particle Expansion Theory (EQPET) model for Tetrahedral Symmetric Condensate (TSC) of H/D mixed systems for Pd host metal. Production ratios of 3 He/ 4 He for multi-body fusion reactions in H/D mixed TSC systems are calculated as a function of H/D mixing ratio. The model is further extended to treat direct nuclear interactions between host-metal nucleus and TSC of pure four protons (or four deuterons), since TSC can become very small (far less than 1 pm radius) charge-neutral pseudo-particle. Results for the case of Ni + 4p/TSC are discussed with Ni + p capture reactions and Ni + 4p fission reactions. (authors)

  20. Studies to enhance the hyperpolarization level in PHIP-SAH-produced C13-pyruvate

    Science.gov (United States)

    Cavallari, Eleonora; Carrera, Carla; Aime, Silvio; Reineri, Francesca

    2018-04-01

    The use of [1-13C]pyruvate, hyperpolarized by dissolution-Dynamic Nuclear Polarization (d-DNP), in in vivo metabolic studies has developed quickly, thanks to the imaging probe's diagnostic relevance. Nevertheless, the cost of a d-DNP polarizer is quite high and the speed of hyperpolarization process is relatively slow, meaning that its use is limited to few research laboratories. ParaHydrogen Induced Polarization Side Arm Hydrogenation (PHIP-SAH) (Reineri et al., 2015) is a cost effective and easy-to-handle method that produces 13C-MR hyperpolarization in [1-13C]pyruvate and other metabolites. This work aims to identify the main determinants of the hyperpolarization levels observed in C13-pyruvate using this method. By dissecting the various steps of the PHIP-SAH procedure, it has been possible to assess the role of several experimental parameters whose optimization must be pursued if this method is to be made suitable for future translational steps. The search for possible solutions has led to improvements in the polarization of sodium [1-13C]pyruvate from 2% to 5%. Moreover, these results suggest that observed polarization levels could be increased considerably by an automatized procedure which would reduce the time required for the work-up passages that are currently carried out manually. The results reported herein mean that the attainment of polarization levels suitable for the metabolic imaging applications of these hyperpolarized substrates show significant promise.

  1. A comparison of exogenous and endogenous CEST MRI methods for evaluating in vivo pH.

    Science.gov (United States)

    Lindeman, Leila R; Randtke, Edward A; High, Rachel A; Jones, Kyle M; Howison, Christine M; Pagel, Mark D

    2018-05-01

    Extracellular pH (pHe) is an important biomarker for cancer cell metabolism. Acido-chemical exchange saturation transfer (CEST) MRI uses the contrast agent iopamidol to create spatial maps of pHe. Measurements of amide proton transfer exchange rates (k ex ) from endogenous CEST MRI were compared to pHe measurements by exogenous acido-CEST MRI to determine whether endogenous k ex could be used as a proxy for pHe measurements. Spatial maps of pHe and k ex were obtained using exogenous acidoCEST MRI and an endogenous CEST MRI analyzed with the omega plot method, respectively, to evaluate mouse kidney, a flank tumor model, and a spontaneous lung tumor model. The pHe and k ex results were evaluated using pixelwise comparisons. The k ex values obtained from endogenous CEST measurements did not correlate with the pHe results from exogenous CEST measurements. The k ex measurements were limited to fewer pixels and had a limited dynamic range relative to pHe measurements. Measurements of k ex with endogenous CEST MRI cannot substitute for pHe measurements with acidoCEST MRI. Whereas endogenous CEST MRI may still have good utility for evaluating some specific pathologies, exogenous acido-CEST MRI is more appropriate when evaluating pathologies based on pHe values. Magn Reson Med 79:2766-2772, 2018. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.

  2. Automated pulmonary lobar ventilation measurements using volume-matched thoracic CT and MRI

    Science.gov (United States)

    Guo, F.; Svenningsen, S.; Bluemke, E.; Rajchl, M.; Yuan, J.; Fenster, A.; Parraga, G.

    2015-03-01

    Objectives: To develop and evaluate an automated registration and segmentation pipeline for regional lobar pulmonary structure-function measurements, using volume-matched thoracic CT and MRI in order to guide therapy. Methods: Ten subjects underwent pulmonary function tests and volume-matched 1H and 3He MRI and thoracic CT during a single 2-hr visit. CT was registered to 1H MRI using an affine method that incorporated block-matching and this was followed by a deformable step using free-form deformation. The resultant deformation field was used to deform the associated CT lobe mask that was generated using commercial software. 3He-1H image registration used the same two-step registration method and 3He ventilation was segmented using hierarchical k-means clustering. Whole lung and lobar 3He ventilation and ventilation defect percent (VDP) were generated by mapping ventilation defects to CT-defined whole lung and lobe volumes. Target CT-3He registration accuracy was evaluated using region- , surface distance- and volume-based metrics. Automated whole lung and lobar VDP was compared with semi-automated and manual results using paired t-tests. Results: The proposed pipeline yielded regional spatial agreement of 88.0+/-0.9% and surface distance error of 3.9+/-0.5 mm. Automated and manual whole lung and lobar ventilation and VDP were not significantly different and they were significantly correlated (r = 0.77, p pulmonary structural-functional maps with high accuracy and robustness, providing an important tool for image-guided pulmonary interventions.

  3. 6 Ma age of carving Westernmost Grand Canyon: Reconciling geologic data with combined AFT, (U-Th)/He, and 4He/3He thermochronologic data

    Science.gov (United States)

    Winn, Carmen; Karlstrom, Karl E.; Shuster, David L.; Kelley, Shari; Fox, Matthew

    2017-09-01

    Conflicting hypotheses about the timing of carving of the Grand Canyon involve either a 70 Ma (;old;) or conflict with these lines of evidence, but are reconciled in this paper via the integration of three methods of analyses on the same sample: apatite (U-Th)/He ages (AHe), 4He/3He thermochronometry (4He/3He), and apatite fission-track ages and lengths (AFT). HeFTy software was used to generate time-temperature (t-T) paths that predict all new and published 4He/3He, AHe, and AFT data to within assumed uncertainties. These t-T paths show cooling from ∼100 °C to 40-60 °C in the Laramide (70-50 Ma), long-term residence at 40-60 °C in the mid-Tertiary (50-10 Ma), and cooling to near-surface temperatures after 10 Ma, and thus support young incision of the westernmost Grand Canyon. A subset of AHe data, when interpreted alone (i.e. without 4He/3He or AFT data), are better predicted by t-T paths that cool to surface temperatures during the Laramide, consistent with an ;old; Grand Canyon. However, the combined AFT, AHe, and 4He/3He analysis of a key sample from Separation Canyon can only be reconciled by a ;young; Canyon. Additional new AFT (5 samples) and AHe data (3 samples) in several locations along the canyon corridor also support a ;young; Canyon. This inconsistency, which mimics the overall controversy of the age of the Grand Canyon, is reconciled here by optimizing cooling paths so they are most consistent with multiple thermochronometers from the same rocks. To do this, we adjusted model parameters and uncertainties to account for uncertainty in the rate of radiation damage annealing in these apatites during sedimentary burial and the resulting variations in He retentivity. In westernmost Grand Canyon, peak burial conditions (temperature and duration) during the Laramide were likely insufficient to fully anneal radiation damage that accumulated during prolonged, near-surface residence since the Proterozoic. We conclude that application of multiple

  4. Production of d, t, 3He, anti d, anti t and anti 3He by 200 GeV protons

    International Nuclear Information System (INIS)

    Bozzoli, W.; Giacomelli, G.; Rimondi, F.; Zylberajch, S.; Lesquoy, E.; Meunier, R.; Moscoso, L.; Muller, A.; Bussiere, A.

    1978-01-01

    Data are presented on the yields of d, t, 3 He, anti d, anti t, and anti 3 He with laboratory momenta between 12 and 37 GeV/c produced by 200 GeV protons on beryllium and aluminium. The production yield of nuclei depends significantly on the target nucleus, while the anti d production is independent of target material. The mass dependence of the production cross section is exponential for both nuclei and antinuclei

  5. Analysis of the collagen birefringence and the relative attenuation coefficient of health and burned skin irradiated with linearly polarized He-Ne laser

    International Nuclear Information System (INIS)

    Silva, Daniela de Fatima Teixeira da

    2002-01-01

    Low-intensity laser therapy is characterized by its ability to induce athermic effects and nondestructive photobiological processes. Although it has been in use for more than 40 years, this phototherapy is still not an established therapeutic modality. The objectives of this study were: to quantify the collagen fibers organization by polarized light microscopy in normal and burned skin samples at day 17 post-injury considering preferential axis as the animal's spinal column and aligning the linear laser polarization in two directions of polarization, parallel or perpendicular to this axis; to determine the relative attenuation coefficient for the intensity light by the technique of imaging the light distribution in normal and burned skin during wound healing process taking only parallel direction of polarization. To reach the objectives, burns about 6 mm in diameter were created with liquid N 2 on the back of the rats and the lesions were irradiated on days 3, 7, 10 and 14 post-wounding, D= 1 J/cm 2 , to investigate the effects of low-intensity linearly polarized He-Ne laser beam on skin wounds healing. Control lesions were not irradiated. The results have demonstrated that: the skin samples irradiated with linearly parallel polarized He-Ne laser beam showed collagen fibers more organized; burned skin samples presents a higher attenuation coefficient than normal skin samples. These results are important to optimize low intensity laser therapy dosimetry on acceleration wound healing. (author)

  6. Coherent photoproduction of π+ on 3He in the (3,3) resonance region

    International Nuclear Information System (INIS)

    Boyard, J.-L.

    1975-01-01

    An experimental study of the 3 He(γ,π + ) 3 H reaction has been performed in the (3,3) resonance region with a bremsstrahlung photon beam and a liquid 3 He target. A magnetic spectrometer followed by a wire chamber analyzed the momentum of the outgoing pions and defined their emission angle. The tritons were detected in coincidence with the pions by two methods: a telescope of thin plastic scintillators below 40MeV; or a magnetic spectrometer followed by a series of plastic scintillators for higher energies. The experiment shows two main features: at a fixed four-momentum transfer q 2 , the resonance is shifted towards lower energies, this shift increasing with q 2 ; at a fixed angle, but variable q 2 , the minimum of the charge form factor observed in the elastic scattering of electrons on 3 He does not appear. Calculations explain partly these two effects [fr

  7. POLARIZED-LIGHT EMISSION IN KEV HE2++NA(3S) COLLISIONS

    NARCIS (Netherlands)

    BODUCH, P; VANBUCHEM, J; BLIEK, FW; HOEKSTRA, R; MORGENSTERN, R; OLSON, RE

    1995-01-01

    We investigated l and m-distributions of He II (n = 4) states formed during 2-13.3 keV amu(-1) He2+ + Na(3s) collisions by measuring profiles and the linear polarization of the He II (4 --> 3) emission. We found that at these energies capture into He+(4f) dominates over capture into other He+(4l)

  8. He++ transport in the PDX tokamak

    International Nuclear Information System (INIS)

    Fonck, R.J.; Hulse, R.A.

    1983-12-01

    A powerful new approach to the study of particle transport and helium ash confinement in high-temperature fusion plasmas is demonstrated by charge-exchange recombination spectroscopy of He ++ in ohmically heated PDX discharges. Time and space resolved measurements of He ++ density following a short puff of helium gas into the plasma edge are fitted using a diffusive/convective transport model with coefficients D = (2.1 +- 0.9) x 10 4 cm 2 s -1 and v(r)/D = (0.8 +- 0.3) delta (ln n/sub e/)/deltar

  9. Development of 3He-BOCA power ramping facility, 1

    International Nuclear Information System (INIS)

    Nakata, Hirokatsu; Ishii, Tadahiko; Itoh, Haruhiko; Abe, Hiroshi; Nakazaki, Chozaburo

    1979-11-01

    Development of a He-3 power controlled boiling water capsule, 3 He-BOCS, for LWR fuels power ramping test in JMTR has been carried out since 1978 on a five-year program; in the reactor, irradiation tests of various fuels and structual materials have been made since 1969. Using stagnant-pressurized water as a thermal medium, the capsule provides pressure and temperature conditions similar to those in LWRs. Heat generation of a fuel pin can be controlled by a He-3 gas screen surrounding the capsule. The facility is capable of testing numbers of both fresh and irradiated fuel pins under LWR operating conditions for power ramping and cycling. After explaining the operating priciples of 3 He-BOCA and the development program, the following are described: the results of preliminary out-of-pile test on heat conductive characteristics of the capsule and a conceptual design of the 3 He-BOCA for power ramping of a short fuel pin from 250 W/cm to 500 W/cm under BWR conditions. (author)

  10. Expectation values of the e+He(3Se) system

    International Nuclear Information System (INIS)

    Mitroy, J.

    2005-01-01

    Close to converged energies and expectation values for e + He( 3 S e ) are computed using a ground state wave function consisting of 1500 explicitly correlated Gaussians. The best estimate of the e + He( 3 S e ) energy was -2.250 595 08 hartree, which has a binding energy of 0.000 595 08 hartree against dissociation into Ps+He + . The 2γ annihilation rate for the spin doublet state was 5.713x10 9 s -1 . The estimated annihilation rate with the core He + electron was 2.506x10 6 s -1 . The derived enhancement factor for annihilation with the He + (1s) core was 2.29, just over 10% smaller than the enhancement factor derived from analyses of annihilation during e + -He + scattering. The diffuse nature of the wave function, with well separated He + and Ps subsystems, is demonstarted to be on the threshold of satisfying the formal criteria that define a quantum halo state

  11. WE-G-BRD-06: Volumetric Cine MRI (VC-MRI) Estimated Based On Prior Knowledge for On-Board Target Localization

    International Nuclear Information System (INIS)

    Harris, W; Yin, F; Cai, J; Zhang, Y; Ren, L

    2015-01-01

    Purpose: To develop a technique to generate on-board VC-MRI using patient prior 4D-MRI, motion modeling and on-board 2D-cine MRI for real-time 3D target verification of liver and lung radiotherapy. Methods: The end-expiration phase images of a 4D-MRI acquired during patient simulation are used as patient prior images. Principal component analysis (PCA) is used to extract 3 major respiratory deformation patterns from the Deformation Field Maps (DFMs) generated between end-expiration phase and all other phases. On-board 2D-cine MRI images are acquired in the axial view. The on-board VC-MRI at any instant is considered as a deformation of the prior MRI at the end-expiration phase. The DFM is represented as a linear combination of the 3 major deformation patterns. The coefficients of the deformation patterns are solved by matching the corresponding 2D slice of the estimated VC-MRI with the acquired single 2D-cine MRI. The method was evaluated using both XCAT (a computerized patient model) simulation of lung cancer patients and MRI data from a real liver cancer patient. The 3D-MRI at every phase except end-expiration phase was used to simulate the ground-truth on-board VC-MRI at different instances, and the center-tumor slice was selected to simulate the on-board 2D-cine images. Results: Image subtraction of ground truth with estimated on-board VC-MRI shows fewer differences than image subtraction of ground truth with prior image. Excellent agreement between profiles was achieved. The normalized cross correlation coefficients between the estimated and ground-truth in the axial, coronal and sagittal views for each time step were >= 0.982, 0.905, 0.961 for XCAT data and >= 0.998, 0.911, 0.9541 for patient data. For XCAT data, the maximum-Volume-Percent-Difference between ground-truth and estimated tumor volumes was 1.6% and the maximum-Center-of-Mass-Shift was 0.9 mm. Conclusion: Preliminary studies demonstrated the feasibility to estimate real-time VC-MRI for on

  12. WE-G-BRD-06: Volumetric Cine MRI (VC-MRI) Estimated Based On Prior Knowledge for On-Board Target Localization

    Energy Technology Data Exchange (ETDEWEB)

    Harris, W; Yin, F; Cai, J; Zhang, Y; Ren, L [Duke University Medical Center, Durham, NC (United States)

    2015-06-15

    Purpose: To develop a technique to generate on-board VC-MRI using patient prior 4D-MRI, motion modeling and on-board 2D-cine MRI for real-time 3D target verification of liver and lung radiotherapy. Methods: The end-expiration phase images of a 4D-MRI acquired during patient simulation are used as patient prior images. Principal component analysis (PCA) is used to extract 3 major respiratory deformation patterns from the Deformation Field Maps (DFMs) generated between end-expiration phase and all other phases. On-board 2D-cine MRI images are acquired in the axial view. The on-board VC-MRI at any instant is considered as a deformation of the prior MRI at the end-expiration phase. The DFM is represented as a linear combination of the 3 major deformation patterns. The coefficients of the deformation patterns are solved by matching the corresponding 2D slice of the estimated VC-MRI with the acquired single 2D-cine MRI. The method was evaluated using both XCAT (a computerized patient model) simulation of lung cancer patients and MRI data from a real liver cancer patient. The 3D-MRI at every phase except end-expiration phase was used to simulate the ground-truth on-board VC-MRI at different instances, and the center-tumor slice was selected to simulate the on-board 2D-cine images. Results: Image subtraction of ground truth with estimated on-board VC-MRI shows fewer differences than image subtraction of ground truth with prior image. Excellent agreement between profiles was achieved. The normalized cross correlation coefficients between the estimated and ground-truth in the axial, coronal and sagittal views for each time step were >= 0.982, 0.905, 0.961 for XCAT data and >= 0.998, 0.911, 0.9541 for patient data. For XCAT data, the maximum-Volume-Percent-Difference between ground-truth and estimated tumor volumes was 1.6% and the maximum-Center-of-Mass-Shift was 0.9 mm. Conclusion: Preliminary studies demonstrated the feasibility to estimate real-time VC-MRI for on

  13. 3He and chlorofluorocarbons (CFC) in the Southern Ocean

    International Nuclear Information System (INIS)

    Jean-Baptiste, P.; Jamous, D.; Mantisi, F.; Memery, L.; Universite Paris 6

    1991-01-01

    The distribution of 3 He across the Southern Ocean is depicted on the basis of a meridional section between Antarctica and South Africa measured during the INDIGO-3 survey (1988). A core of δ 3 He values above 10% is observed south of the Polar Front, associated with very low CFC concentrations. This 3 He enriched layer is documented from the GEOSECS and INDIGO 3 He data in the Southern Ocean. It is found at a density level around θ σ =27.8 in all the waters close to Antarctica (i.e. south of 50 degS). Its zonal distribution suggests that it is likely that it originates from the central/eastern Pacific. Hence, it provides an indication of the deep Pacific waters in the Antarctic Circumpolar Current, which are not easily detectable from the standard hydrographic parameters. (author). 19 refs.; 8 figs

  14. Hyperpolarized Amino Acid Derivatives as Multivalent Magnetic Resonance pH Sensor Molecules

    Directory of Open Access Journals (Sweden)

    Christian Hundshammer

    2018-02-01

    Full Text Available pH is a tightly regulated physiological parameter that is often altered in diseased states like cancer. The development of biosensors that can be used to non-invasively image pH with hyperpolarized (HP magnetic resonance spectroscopic imaging has therefore recently gained tremendous interest. However, most of the known HP-sensors have only individually and not comprehensively been analyzed for their biocompatibility, their pH sensitivity under physiological conditions, and the effects of chemical derivatization on their logarithmic acid dissociation constant (pKa. Proteinogenic amino acids are biocompatible, can be hyperpolarized and have at least two pH sensitive moieties. However, they do not exhibit a pH sensitivity in the physiologically relevant pH range. Here, we developed a systematic approach to tailor the pKa of molecules using modifications of carbon chain length and derivatization rendering these molecules interesting for pH biosensing. Notably, we identified several derivatives such as [1-13C]serine amide and [1-13C]-2,3-diaminopropionic acid as novel pH sensors. They bear several spin-1/2 nuclei (13C, 15N, 31P with high sensitivity up to 4.8 ppm/pH and we show that 13C spins can be hyperpolarized with dissolution dynamic polarization (DNP. Our findings elucidate the molecular mechanisms of chemical shift pH sensors that might help to design tailored probes for specific pH in vivo imaging applications.

  15. Hyperpolarized Amino Acid Derivatives as Multivalent Magnetic Resonance pH Sensor Molecules.

    Science.gov (United States)

    Hundshammer, Christian; Düwel, Stephan; Ruseckas, David; Topping, Geoffrey; Dzien, Piotr; Müller, Christoph; Feuerecker, Benedikt; Hövener, Jan B; Haase, Axel; Schwaiger, Markus; Glaser, Steffen J; Schilling, Franz

    2018-02-15

    pH is a tightly regulated physiological parameter that is often altered in diseased states like cancer. The development of biosensors that can be used to non-invasively image pH with hyperpolarized (HP) magnetic resonance spectroscopic imaging has therefore recently gained tremendous interest. However, most of the known HP-sensors have only individually and not comprehensively been analyzed for their biocompatibility, their pH sensitivity under physiological conditions, and the effects of chemical derivatization on their logarithmic acid dissociation constant (p K a ). Proteinogenic amino acids are biocompatible, can be hyperpolarized and have at least two pH sensitive moieties. However, they do not exhibit a pH sensitivity in the physiologically relevant pH range. Here, we developed a systematic approach to tailor the p K a of molecules using modifications of carbon chain length and derivatization rendering these molecules interesting for pH biosensing. Notably, we identified several derivatives such as [1- 13 C]serine amide and [1- 13 C]-2,3-diaminopropionic acid as novel pH sensors. They bear several spin-1/2 nuclei ( 13 C, 15 N, 31 P) with high sensitivity up to 4.8 ppm/pH and we show that 13 C spins can be hyperpolarized with dissolution dynamic polarization (DNP). Our findings elucidate the molecular mechanisms of chemical shift pH sensors that might help to design tailored probes for specific pH in vivo imaging applications.

  16. Effect of membrane hyperpolarization induced by a K+ channel opener on histamine-induced Ca2+ mobilization in rabbit arterial smooth muscle.

    Science.gov (United States)

    Watanabe, Y; Suzuki, A; Suzuki, H; Itoh, T

    1996-03-01

    1. The role of membrane hyperpolarization on agonist-induced contraction was investigated in intact and alpha-toxin-skinned smooth muscles of rabbit mesenteric artery by use of the ATP-sensitive K+ channel opener, (-)-(3S,4R)-4-(N-acetyl-N-hydroxyamino)-6-cyano-3,4-dihydro-2,2- dimethyl-2H-1-benzopyran-3-ol (Y-26763), and either histamine (Hist) or noradrenaline (NA). 2. Hist (3 microM) and NA (10 microM) both produced a phasic, followed by a tonic increase in intracellular Ca2+ concentration ([Ca2+]i) and force. Y-26763 (10 microM) potently inhibited the NA-induced phasic and tonic increase in [Ca2+]i and force. In contrast, Y-26763 attenuated the Hist-induced phasic increase in [Ca2+]i and force but had almost no effect on the tonic response. However, ryanodine-treatment of muscles in order to inhibit the function of intracellular Ca2+ storage sites altered the action of Y-26763 which now attenuated the Hist-induced tonic increase in [Ca2+]i and force in a concentration-dependent manner (at concentrations > 1 microM). Glibenclamide (10 microM) attenuated the inhibitory action of Y-26763. 3. Hist (3 microM) depolarized the smooth muscle cells to the same extent as NA (10 microM). In the absence of either agonist, Y-26763 (over 30 nM) hyperpolarized the membrane and glibenclamide inhibited this hyperpolarization. Y-26763 (10 microM) almost abolished the NA-induced membrane depolarization, but only slightly attenuated the Hist-induced membrane depolarization in which the delta (delta) value (the difference before and after application of Hist) was not modified by any concentration of Y-26763. In ryanodine-treated smooth muscle cells, Y-26763 hyperpolarized the membrane and potently inhibited the membrane depolarization induced by Hist. 4. In ryanodine-treated muscle, Y-26763 had no measurable effect on the Hist-induced [Ca2+]i-force relationship. Y-26763 also had no apparent effect on the myofilament Ca(2+)-sensitivity in the presence of Hist in alpha

  17. Saffold Virus Type 3 (SAFV-3) Persists in HeLa Cells

    Science.gov (United States)

    Himeda, Toshiki; Hosomi, Takushi; Okuwa, Takako; Muraki, Yasushi; Ohara, Yoshiro

    2013-01-01

    Saffold virus (SAFV) was identified as a human cardiovirus in 2007. Although several epidemiological studies have been reported, they have failed to provide a clear picture of the relationship between SAFV and human diseases. SAFV genotype 3 has been isolated from the cerebrospinal fluid specimen of patient with aseptic meningitis. This finding is of interest since Theiler’s murine encephalomyelitis virus (TMEV), which is the closely related virus, is known to cause a multiple sclerosis-like syndrome in mice. TMEV persistently infects in mouse macrophage cells in vivo and in vitro, and the viral persistence is essential in TMEV-induced demyelinating disease. The precise mechanism(s) of SAFV infection still remain unclear. In order to clarify the SAFV pathogenicity, in the present study, we studied the possibilities of the in vitro persistent infection of SAFV. The two distinct phenotypes of HeLa cells, HeLa-N and HeLa-R, were identified. In these cells, the type of SAFV-3 infection was clearly different. HeLa-N cells were lyticly infected with SAFV-3 and the host suitable for the efficient growth. On the other hand, HeLa-R cells were persistently infected with SAFV-3. In addition, the SAFV persistence in HeLa-R cells is independent of type I IFN response of host cells although the TMEV persistence in mouse macrophage cells depends on the response. Furthermore, it was suggested that SAFV persistence may be influenced by the expression of receptor(s) for SAFV infection on the host cells. The present findings on SAFV persistence will provide the important information to encourage the research of SAFV pathogenicity. PMID:23308162

  18. Research progress of BOLD-functional MRI of hepatic encephalopathy

    International Nuclear Information System (INIS)

    Ni Ling; Zhang Longjiang; Lu Guangming

    2013-01-01

    Hepatic encephalopathy (HE), characterized by a wide spectrum of clinical manifestations, ranging from behavior abnormality, conscious disorder and even coma, is a consequence of liver dysfunction in both acute and chronic hepatic diseases. Minimal hepatic encephalopathy (MHE) refers to a subgroup of cirrhotic patients without clinical overt hepatic encephalopathy symptoms hut with abnormalities in neuro -cognitive functions. HE/MHE can have a far-reaching impact on quality of life and prognosis. The exact neuropathology mechanism was still unclear. Recently, functional MRI (fMRI) has been increasingly applied for investigating the neuro-pathophysiological mechanism of HE. This paper will review the fMRI research applied on uncovering the neuropathology mechanism of HE. (authors)

  19. Analysis of the reaction 3He + p → p + p + d at 2,5 GeV/c 3He nucleus momentum

    International Nuclear Information System (INIS)

    Blinov, A.V.; Chuvilo, I.V.; Drobot, V.V.

    1984-01-01

    The experimental data on the reaction 3 He+p → p+p+d obtained by the exposition of an 80 cm liquid hydrogen bubble chamber to the 3 He nucleus beam at 2.5 GeV/c momentum are considered. The angular, momentum and invariant mass distributions, which have been measured, are compared with theoretical calculations performed using the pole model. On the whole a satisfactory agreement between theoretical and experimental data is found in the kinematical region, where pd- rescattering effects are negligible. It is concluded, that 3 He nuclear wave function calculated by means of nonrelativistic potential models falls too sharply with the spectator momenta as compared with the data

  20. Technic and economic viability study on exploitation of lunar 3He resource

    International Nuclear Information System (INIS)

    Deng Baiquan

    1995-01-01

    From the energetics point of view, the technic and economic viability study on exploitation of lunar 3 He for fuelling the fusion reactor burning D- 3 He has been carried out. This study is divided into the following sections: analysis of solar wind parameters and estimation of potential quantity 3 He in the lunar regolith, the cost evaluation of mining He of lunar soil; the energy cost calculation of He extraction by vacuum heating degassing during lunar day, the cost calculation of cryogenic isotopic separation 3 He/ 4 He during the lunar night, the energy cost for earth/moon transportation of liquid 3 He, the energy payback calculation of fusion power burning 3 He based lunar source, and finally the comparison of the energy multiplication with that for 235 U production of nuclear fuel and for coal mining. The comparisons of cost of electricity between D- 3 He and D-T fuel cycle for different reactor types have been discussed

  1. Free-breathing quantification of hepatic fat in healthy children and children with nonalcoholic fatty liver disease using a multi-echo 3-D stack-of-radial MRI technique.

    Science.gov (United States)

    Armstrong, Tess; Ly, Karrie V; Murthy, Smruthi; Ghahremani, Shahnaz; Kim, Grace Hyun J; Calkins, Kara L; Wu, Holden H

    2018-05-04

    In adults, noninvasive chemical shift encoded Cartesian magnetic resonance imaging (MRI) and single-voxel magnetic resonance (MR) spectroscopy (SVS) accurately quantify hepatic steatosis but require breath-holding. In children, especially young and sick children, breath-holding is often limited or not feasible. Sedation can facilitate breath-holding but is highly undesirable. For these reasons, there is a need to develop free-breathing MRI technology that accurately quantifies steatosis in all children. This study aimed to compare non-sedated free-breathing multi-echo 3-D stack-of-radial (radial) MRI versus standard breath-holding MRI and SVS techniques in a group of children for fat quantification with respect to image quality, accuracy and repeatability. Healthy children (n=10, median age [±interquartile range]: 10.9 [±3.3] years) and overweight children with nonalcoholic fatty liver disease (NAFLD) (n=9, median age: 15.2 [±3.2] years) were imaged at 3 Tesla using free-breathing radial MRI, breath-holding Cartesian MRI and breath-holding SVS. Acquisitions were performed twice to assess repeatability (within-subject mean difference, MD within ). Images and hepatic proton-density fat fraction (PDFF) maps were scored for image quality. Free-breathing and breath-holding PDFF were compared using linear regression (correlation coefficient, r and concordance correlation coefficient, ρ c ) and Bland-Altman analysis (mean difference). Phepatic PDFF measurements and improved image quality, compared to standard breath-holding MR techniques.

  2. Spin Superfluidity and Magnone BEC in He-3

    Science.gov (United States)

    Bunkov, Yury

    2011-03-01

    The spin superfluidity -- superfluidity in the magnetic subsystem of a condensed matter -- is manifested as the spontaneous phase-coherent precession of spins first discovered in 1984 in 3 He-B. This superfluid current of spins -- spin supercurrent -- is one more representative of superfluid currents known or discussed in other systems, such as the superfluid current of mass and atoms in superfluid 4 He; superfluid current of electric charge in superconductors; superfluid current of hypercharge in Standard Model of particle physics; superfluid baryonic current and current of chiral charge in quark matter; etc. Spin superfluidity can be described in terms of the Bose condensation of spin waves -- magnons. We discuss different states of magnon superfluidity with different types of spin-orbit coupling: in bulk 3 He-B; magnetically traped `` Q -balls'' at very low temperatures; in 3 He-A and 3 He-B immerged in deformed aerogel; etc. Some effects in normal 3 He can also be treated as a magnetic BEC of fermi liquid. A very similar phenomena can be observed also in a magnetic systems with dinamical frequensy shift, like MnC03 . We will discuss the main experimental signatures of magnons superfluidity: (i) spin supercurrent, which transports the magnetization on a macroscopic distance more than 1 cm long; (ii) spin current Josephson effect which shows interference between two condensates; (iii) spin current vortex -- a topological defect which is an analog of a quantized vortex in superfluids, of an Abrikosov vortex in superconductors, and cosmic strings in relativistic theories; (iv) Goldstone modes related to the broken U (1) symmetry -- phonons in the spin-superfluid magnon gas; etc. For recent review see Yu. M. Bunkov and G. E. Volovik J. Phys. Cond. Matter. 22, 164210 (2010) This work is partly supported by the Ministry of Education and Science of the Russian Federation (contract N 02.740.11.5217).

  3. Second sound, osmotic pressure, and Fermi-liquid parameters in 3He-4He solutions

    International Nuclear Information System (INIS)

    Corruccini, L.R.

    1984-01-01

    Second-sound velocities and osmotic pressures are analyzed to obtain the first experimental values for the Landau compressibility parameter F 0 /sup s/ in 3 He- 4 He solutions. Data are presented as a function of pressure and 3 He concentration, and are compared to theoretical predictions. The square of the second-sound velocity at finite temperature is found to be accurately proportional to the internal energy of a perfect Fermi gas. Using inertial effective masses given by the Landau-Pomeranchuk theory, the square of the velocity is found to separate into two parts: a temperature-dependent part characterized completely by ideal Fermi-gas behavior and a temperature-independent part containing all the Fermi-liquid corrections. This is related to a similar separation found in the osmotic pressure

  4. 3He electron scattering sum rules

    International Nuclear Information System (INIS)

    Kim, Y.E.; Tornow, V.

    1982-01-01

    Electron scattering sum rules for 3 He are derived with a realistic ground-state wave function. The theoretical results are compared with the experimentally measured integrated cross sections. (author)

  5. Lowest vibrational states of 4He3He+: Non-Born-Oppenheimer calculations

    International Nuclear Information System (INIS)

    Stanke, Monika; Bubin, Sergiy; Kedziera, Dariusz; Molski, Marcin; Adamowicz, Ludwik

    2007-01-01

    Very accurate quantum mechanical calculations of the first five vibrational states of the 4 He 3 He + molecular ion are reported. The calculations have been performed explicitly including the coupling of the electronic and nuclear motions [i.e., without assuming the Born-Oppenheimer (BO) approximation]. The nonrelativistic non-BO wave functions were used to calculate the α 2 relativistic mass velocity, Darwin, and spin-spin interaction corrections. For the lowest vibrational transition, whose experimental energy is established with high precision, the calculated and the experimental results differ by only 0.16 cm -1

  6. Development of polarized {sup 3}He filter for polarized neutron experiment

    Energy Technology Data Exchange (ETDEWEB)

    Sakai, K.; Sato, H.; Yoshimi, A.; Asahi, K. [Tokyo Inst. of Tech. (Japan). Faculty of Science; Masuda, Y.; Muto, S.; Ishimoto, S.; Morimoto, K.

    1996-08-01

    A high-pressure polarized {sup 3}He gas cell, pumped with two diode lasers, has been developed at KEK for use as a polarizer and a spin analyzer for low energy neutrons. The polarization attained of {sup 3}He was determined through the measurement of the transmission of the unpolarized neutrons through the {sup 3}He cell. So far we obtained P{sub He}=18% at 10 atm and P{sub He}=12% at 20 atm. (author)

  7. Local staging of sigmoid colon cancer using MRI

    DEFF Research Database (Denmark)

    Dam, Claus; Lindebjerg, Jan; Jakobsen, Anders

    2017-01-01

    BACKGROUND: An accurate radiological staging of colon cancer is crucial to select patients who may benefit from neoadjuvant chemotherapy. PURPOSE: To evaluate the diagnostic accuracy of preoperative magnetic resonance imaging (MRI) in identifying locally advanced sigmoid colon cancer, poor...... prognostic factors, and the inter-observer variation of the tumor apparent diffusion coefficient (ADC) values of diffusion-weighted imaging (DWI). MATERIAL AND METHODS: Using 1.5 T MRI with high resolution T2-weighted (T2W) imaging, DWI, and no contrast enhancement, 35 patients with sigmoid colon cancer were...... the measured mean ADC values were below 1.0 × 10(-3) mm(2)/s with an intra-class correlation coefficient in T3cd-T4 tumors of 0.85. CONCLUSION: Preoperative MRI can identify locally advanced sigmoid colon cancer and has potential as the imaging of choice to select patients for neoadjuvant chemotherapy. Initial...

  8. Study of the {sup 6}Li + p → {sup 3}He + {sup 4}He reaction in inverse kinematics

    Energy Technology Data Exchange (ETDEWEB)

    Betsou, C.; Pakou, A.; Aslanoglou, X.; Nicolis, N.G.; Sgouros, O.; Soukeras, V. [The University of Ioannina, Department of Physics and HINP, Ioannina (Greece); Cappuzzello, F. [Laboratori Nazionali del Sud, INFN, Catania (Italy); Universita di Catania, Dipartimento di Fisica e Astronomia, Catania (Italy); Acosta, L. [Universidad Nacional Autonoma de Mexico, Instituto de Fisica, Mexico Distrito Federal (Mexico); INFN, Catania (Italy); Agodi, C.; Carbone, D.; Cavallaro, M.; Di Pietro, A.; Fernandez-Garcia, J.P.; Figuera, P.; Fisichella, M. [Laboratori Nazionali del Sud, INFN, Catania (Italy); Foti, A. [Universita di Catania, Dipartimento di Fisica e Astronomia, Catania (Italy); INFN, Catania (Italy); Keeley, N. [National Centre for Nuclear Research, Otwock (Poland); Marquinez-Duran, G.; Martel, I. [Universidad de Huelva, Departamento de Fisica Aplicada, Huelva (Spain); Mazzocco, M.; Strano, E.; Torresi, D. [Universita di Padova, Departimento di Fisica e Astronomia, Padova (Italy); INFN, Padova (Italy); Pierroutsakou, D. [INFN, Napoli (Italy); Rusek, K. [University of Warsaw, Heavy Ion Laboratory, Warsaw (Poland); Stiliaris, E. [University of Athens, Institute of Accelerating Systems and Applications and Department of Physics, Athens (Greece)

    2015-07-15

    Angular distribution measurements were performed for the {sup 6}Li + p → {sup 3}He + {sup 4}He reaction in inverse kinematics at incident energies of 2.7, 3.3, 4.2 and 4.8 MeV/u. The detection of both recoils ({sup 3}He and {sup 4}He) over the laboratory angle range θ{sub lab} = 16 {sup circle} to 34 {sup circle} allowed the determination of the angular distribution over a wide angular range in the center-of-mass frame (θ{sub c.m.} ∝ 40 {sup circle} to 140 {sup circle}). The results clarify inconsistencies between existing data sets and are consistent with compound nucleus model calculations. (orig.)

  9. New Insights into Signed Path Coefficient Granger Causality Analysis.

    Science.gov (United States)

    Zhang, Jian; Li, Chong; Jiang, Tianzi

    2016-01-01

    Granger causality analysis, as a time series analysis technique derived from econometrics, has been applied in an ever-increasing number of publications in the field of neuroscience, including fMRI, EEG/MEG, and fNIRS. The present study mainly focuses on the validity of "signed path coefficient Granger causality," a Granger-causality-derived analysis method that has been adopted by many fMRI researches in the last few years. This method generally estimates the causality effect among the time series by an order-1 autoregression, and defines a positive or negative coefficient as an "excitatory" or "inhibitory" influence. In the current work we conducted a series of computations from resting-state fMRI data and simulation experiments to illustrate the signed path coefficient method was flawed and untenable, due to the fact that the autoregressive coefficients were not always consistent with the real causal relationships and this would inevitablely lead to erroneous conclusions. Overall our findings suggested that the applicability of this kind of causality analysis was rather limited, hence researchers should be more cautious in applying the signed path coefficient Granger causality to fMRI data to avoid misinterpretation.

  10. Pionic annihilation of antiprotons stopped on 3He

    International Nuclear Information System (INIS)

    Bendiscioli, G.; Filippini, V.; Rotondi, A.; Salvini, P.; Venaglioni, A.; Bossolasco, S.; Bussa, M.P.; Busso, L.; Fava, L.; Ferrero, L.; Maggiora, A.; Panzieri, D.; Piragino, G.; Piragino, R.; Tosello, F.; Batusov, Yu.A.; Falomkin, I.V.; Pontecorvo, G.B.; Rozhdestvensky, A.M.; Sapozhnikov, M.G.; Tretyak, V.I.; Guaraldo, C.; Haatuft, A.; Halsteinslid, A.; Myklebost, K.; Olsen, J.M.; Zenoni, A.

    1990-01-01

    The pionic annihilation of antiprotons stopped on 3 He nuclei in a self-shunted streamer chamber exposed to the antiproton beam of LEAR is studied. The data concern charged-particle multiplicity distributions, branching ratios for different final states, the probability of final-state interaction, π - , π + , p and d momentum spectra, like and unlike pion angular correlations, π and other charged-particle angular correlations. The comparison of the 3 He data with those obtained on 1 H, 2 H and 4 He does not reveal relevant effects due to the increase of the nucleon number; the small differences can be seen as due to a weak final-state interaction. (orig.)

  11. 4He(γ,n)3He photodisintegration and the properties of O+-resonance of 4He by the resonating group method

    International Nuclear Information System (INIS)

    Filippov, G.F.; Vasilevsky, V.S.; Kovalenko, T.P.

    1984-01-01

    The reaction of 4 He electrodisintegration at small momenta transfered to the nucleus by electrons is considered on the basis of an algebraic version of the resonating group method. The calculated matrix element of the monopole transition from the ground state of 4 He into the O + -resonance state and the calculated monopole energy weighted sum rules confirm the assumption on the cluster nature of O + -resonance. In the dipole approximation the photonuclear reaction of 4 He(γ, n)He 3 at small energies of γ-quanta is studied. The obtained values of the electric dipole transition probabilities and the effective cross sections reveal a good agreement with experimental data

  12. Optical hyperpolarization of 13C nuclear spins in nanodiamond ensembles

    Science.gov (United States)

    Chen, Q.; Schwarz, I.; Jelezko, F.; Retzker, A.; Plenio, M. B.

    2015-11-01

    Dynamical nuclear polarization holds the key for orders of magnitude enhancements of nuclear magnetic resonance signals which, in turn, would enable a wide range of novel applications in biomedical sciences. However, current implementations of DNP require cryogenic temperatures and long times for achieving high polarization. Here we propose and analyze in detail protocols that can achieve rapid hyperpolarization of 13C nuclear spins in randomly oriented ensembles of nanodiamonds at room temperature. Our protocols exploit a combination of optical polarization of electron spins in nitrogen-vacancy centers and the transfer of this polarization to 13C nuclei by means of microwave control to overcome the severe challenges that are posed by the random orientation of the nanodiamonds and their nitrogen-vacancy centers. Specifically, these random orientations result in exceedingly large energy variations of the electron spin levels that render the polarization and coherent control of the nitrogen-vacancy center electron spins as well as the control of their coherent interaction with the surrounding 13C nuclear spins highly inefficient. We address these challenges by a combination of an off-resonant microwave double resonance scheme in conjunction with a realization of the integrated solid effect which, together with adiabatic rotations of external magnetic fields or rotations of nanodiamonds, leads to a protocol that achieves high levels of hyperpolarization of the entire nuclear-spin bath in a randomly oriented ensemble of nanodiamonds even at room temperature. This hyperpolarization together with the long nuclear-spin polarization lifetimes in nanodiamonds and the relatively high density of 13C nuclei has the potential to result in a major signal enhancement in 13C nuclear magnetic resonance imaging and suggests functionalized and hyperpolarized nanodiamonds as a unique probe for molecular imaging both in vitro and in vivo.

  13. Long-range interactions of excited He atoms with ground-state noble-gas atoms

    KAUST Repository

    Zhang, J.-Y.; Qian, Ying; Schwingenschlö gl, Udo; Yan, Z.-C.

    2013-01-01

    The dispersion coefficients C6, C8, and C10 for long-range interactions of He(n1,3S) and He(n1,3P), 2≤n≤10, with the ground-state noble-gas atoms Ne, Ar, Kr, and Xe are calculated by summing over the reduced matrix elements of multipole transition

  14. 16-Channel surface coil for 13C-hyperpolarized spectroscopic imaging of cardiac metabolism in pig heart

    DEFF Research Database (Denmark)

    Frijia, Francesca; Santarelli, Maria Filomena; Koellisch, Ulrich

    2016-01-01

    Magnetic resonance spectroscopy (MRS) of hyperpolarized 13C pyruvate and its metabolites in large animal models is a powerful tool for assessing cardiac metabolism in patho-physiological conditions. In 13C studies, a high signal-to-noise ratio (SNR) is crucial to overcome the intrinsic data quality...... both targets. In this study, a 16-channel receive surface coil was designed for 13C hyperpolarized studies of the pig heart with a clinical 3-T scanner. The coil performance was characterized by phantom experiments and compared with that of a birdcage coil used in transmit/receive mode. Segmental...... of the 16-channel coil is recommended for studies of septal and anterior LV walls....

  15. Long-range interactions of excited He atoms with the alkaline earth atoms Mg, Ca, and Sr

    KAUST Repository

    Zhang, J.-Y.; Babb, J. F.; Mitroy, J.; Sadeghpour, H. R.; Schwingenschlö gl, Udo; Yan, Z.-C.

    2013-01-01

    Dispersion coefficients for the long-range interactions of the first four excited states of He, i.e., He(2 1, 3 S) and He(2 1, 3 P), with the low-lying states of the alkaline earth atoms Mg, Ca, and Sr are calculated by summing over the reduced matrix elements of multipole transition operators.

  16. Long-range interactions of excited He atoms with the alkaline earth atoms Mg, Ca, and Sr

    KAUST Repository

    Zhang, J.-Y.

    2013-04-05

    Dispersion coefficients for the long-range interactions of the first four excited states of He, i.e., He(2 1, 3 S) and He(2 1, 3 P), with the low-lying states of the alkaline earth atoms Mg, Ca, and Sr are calculated by summing over the reduced matrix elements of multipole transition operators.

  17. Non-uniform 3He polarization formed by multiple collisions of a fast 3He+ ion with polarized Rb vapor in a strong magnetic field

    International Nuclear Information System (INIS)

    Arimoto, Y.; Yonehara, K.; Yamagata, T.; Tanaka, M.

    2001-01-01

    We investigated the spatial distribution of a polarization in 3 He beam expected from a novel polarized 3 He ion source based on electron pumping, i.e., multiple electron capture and stripping collisions of an incident fast 3 He + ion with a polarized Rb vapor in a strong axial magnetic field. For this purpose, a Monte Carlo simulation was carried out for 19 keV 3 He + ions with varying Rb vapor thickness, magnetic field, and beam emittance. The calculated results showed a distribution of the 3 He polarization that we call a 'polarization hole', which has a low polarization area around the beam axis. The parameters characterizing the polarization hole, i.e., the polarization and radius of the hole, were found to depend on the Rb vapor thickness, the magnetic field, the beam size, and the angular divergence of the initial beam. These parameters were successfully reproduced with analytical functions deduced from a probability density function prescription. This provides a powerful tool to treat complex phenomena of multiple collisions in strong magnetic fields without performing time-consuming Monte Carlo calculations

  18. D-3He fuel cycles for neutron lean reactors

    International Nuclear Information System (INIS)

    Kernbichler, W.; Miley, G.H.; Heindler, M.

    1989-01-01

    The intrinsic potential of D-3He as a reactor fuel is investigated for a large range of 3He to D density ratios. A steady-state zero-dimensional reactor model is developed in which much care is attributed to a proper treatment of fast fusion products. Useful ranges of reactor parameters as well as temperature-density windows for driven and ignited operation are identified. Various figures of merit are calculated, such as power densities, net power production, neutron production, tritium load and radiative power. These results suggest several optimistic conclusions about the performance of D-3He as a reactor fuel

  19. Geometrical aspects of reaction cross sections for {sup 3}He, {sup 4}He and {sup 12}C projectiles

    Energy Technology Data Exchange (ETDEWEB)

    Ingemarsson, A. [Uppsala Univ. (Sweden). Dept. of Radiation Sciences; Lantz, M. [Uppsala Univ. (Sweden). The Svedberg Laboratory

    2003-04-01

    A black-disc model combined with accurate matter densities has been used for an investigation of reaction cross sections for {sup 3}He, {sup 4}He and {sup 12}C projectiles. A simple relation is derived between the energy dependence of the reaction cross sections and the strength of the nucleon-nucleon interaction. A comparison is also made of the reaction cross sections for {sup 3}He and {sup 4}He for six different nuclei {sup 12}C, {sup 16}O, {sup 40}Ca, {sup 58,60}Ni and {sup 208}Pb.

  20. Differentiation between benign and malignant breast lesions using quantitative diffusion-weighted sequence on 3 T MRI

    International Nuclear Information System (INIS)

    Tan, S.L.L.; Rahmat, K.; Rozalli, F.I.; Mohd-Shah, M.N.; Aziz, Y.F.A.; Yip, C.H.; Vijayananthan, A.; Ng, K.H.

    2014-01-01

    Aim: To investigate the capability and diagnostic accuracy of diffusion-weighted imaging (DWI) in differentiating benign from malignant breast lesions using 3 T magnetic resonance imaging (MRI). Materials and methods: Women with suspicious or indeterminate breast lesions detected at MRI, mammogram and/or ultrasound were recruited for dynamic contrast-enhanced (DCE)-MRI and DWI prior to their biopsy. Image fusion of DCE-MRI with apparent diffusion coefficient (ADC) map was utilized to select the region of interest (ROI) for ADC calculation in the area that showed the most avid enhancement. DWI was performed using two sets of b-values at 500 and 1000 s/mm 2 , respectively. Results: Fifty women were recruited and the final analysis comprised 44 breast lesions, 31 of which were malignant and 13 were benign. Significant results were obtained between ADC values of benign and malignant lesions (p −3 mm 2 /s for b = 500 s/mm 2 and 1.22 × 10 −3 mm 2 /s for b = 1000 s/mm 2 , respectively. The sensitivity of DCE-MRI alone was 100% with a specificity of 66.7%. When DCE-MRI was combined with b = 1000 s/mm 2 , the specificity rose to 100%, while only mildly affecting sensitivity (90.6%). No significant correlation was found between ADC values and prognostic factors, such as lymph node metastasis, tumour size, oestrogen receptor (ER), progesterone receptor (PR), and human epidermal growth factor receptor 2 (HER2) status, and tumour grades. Conclusion: The present study provides consistent evidence to support DWI as a diagnostic tool for breast lesion characterization. A combination of DCE-MRI with DWI is suggested to improve the sensitivity and specificity of lesion characterization

  1. Functional and molecular imaging with MRI: potential applications in paediatric radiology

    International Nuclear Information System (INIS)

    Arthurs, Owen J.; Gallagher, Ferdia A.

    2011-01-01

    MRI is a very versatile tool for noninvasive imaging and it is particularly attractive as an imaging technique in paediatric patients given the absence of ionizing radiation. Recent advances in the field of MRI have enabled tissue function to be probed noninvasively, and increasingly MRI is being used to assess cellular and molecular processes. For example, dynamic contrast-enhanced MRI has been used to assess tissue vascularity, diffusion-weighted imaging can quantify molecular movements of water in tissue compartments and MR spectroscopy provides a quantitative assessment of metabolite levels. A number of targeted contrast agents have been developed that bind specifically to receptors on the vascular endothelium or cell surface and there are several MR methods for labelling cells and tracking cellular movements. Hyperpolarization techniques have the capability of massively increasing the sensitivity of MRI and these have been used to image tissue pH, successful response to drug treatment as well as imaging the microstructure of the lungs. Although there are many challenges to be overcome before these techniques can be translated into routine paediatric imaging, they could potentially be used to aid diagnosis, predict disease outcome, target biopsies and determine treatment response noninvasively. (orig.)

  2. Conceptual design of D-3He FRC reactor 'ARTEMIS'

    International Nuclear Information System (INIS)

    Momota, H.; Ishida, A.; Kohzaki, Y.

    1991-07-01

    A comprehensive design study of the D- 3 He fueled field-reversed configuration (FRC) reactor 'ARTEMIS' is carried out for the purpose of proving its attractive characteristics and clarifying the critical issues for a commercial fusion reactor. The FRC burning plasma is stabilized and sustained in a steady equilibrium by means of a preferential trapping of D- 3 He fusion-produced energetic protons. A novel direct energy converter for 15MeV protons is also presented. On the bases of a consistent scenario of the fusion plasma production and simple engineering, a compact and simple reactor concept is presented. The design of the D- 3 He FRC power plant definitely offers the most attractive prospect for energy development. It is environmentally acceptable in view of radio-activity and fuel resources; and the estimated cost of electricity is low compared to a light water reactor. Critical issues concerning physics or engineering for the development of the D- 3 He FRC reactor are clarified. (author)

  3. The influence of (n-n')-mixing processes in He*(n)+He(1s2) collisions on He*(n) atoms' populations in weakly ionized helium plasmas

    International Nuclear Information System (INIS)

    Mihajlov, A.A.; Ignjatovic, Lj.M.; Sreckovic, V.A.; Djuric, Z.

    2008-01-01

    The results of semi-classical calculations of rate coefficients of (n-n ' )-mixing processes due to collisions of Rydberg atoms He*(n) with He(1s 2 ) atoms are presented. It is assumed that these processes are caused by the resonant energy exchange within the electron component of He*(n)+He collision system. The method is realized through the numerical simulation of the (n-n ' )-mixing processes, and is applied for calculations of the corresponding rate coefficients. The calculations are performed for the principal quantum numbers n,n ' in ranges 4≤n ' ≤10, and the atom and electron temperatures, T a ,T e , in domains 5000K≤T a ≤T e ≤20000K. It is shown that the (n-n ' )-mixing processes can significantly influence the populations of Rydberg atoms in non-equilibrium weakly ionized helium plasmas with ionization degree ∼10 -4 . Therefore, these processes have to be included in the appropriate models of such plasmas

  4. Elastic and charge-exchange scattering of pions from 3He and 3H

    International Nuclear Information System (INIS)

    Gibson, B.F.; Hess, A.T.

    1976-04-01

    We have examined (1) the elastic scattering of pions from the isodoublet 3 He and 3 H and (2) the single charge-exchange reaction 3 H(π + ,π 0 ) 3 He using a formalism which incorporates the π-N multiple scattering to all orders. Emphasis is placed on numerical results which illustrate those features of the differential cross sections that are expected to be of interest to the experimentalist. Realistic nuclear densities corresponding to the form factors of elastic electron scattering were used. Charge-exchange cross sections are presented in terms of angular distributions for both the π 0 and the recoil nucleus. In elastic scattering, Coulomb-nuclear interference effects are significant at incident pion kinetic energies of less than 100 MeV; form factor effects are apparent at large momentum transfer. Comparison of data and theory for π + - 3 He with that for π - - 3 He (or the conjugate π + - 3 H) will provide a test of the convergence of the fixed scatterer, multiple-scattering formalism utilized in this report. 21 figures

  5. Modeling non-linear kinetics of hyperpolarized [1-(13)C] pyruvate in the crystalloid-perfused rat heart

    NARCIS (Netherlands)

    Mariotti, E.; Orton, M. R.; Eerbeek, O.; Ashruf, J. F.; Zuurbier, C. J.; Southworth, R.; Eykyn, T. R.

    2016-01-01

    Hyperpolarized (13)C MR measurements have the potential to display non-linear kinetics. We have developed an approach to describe possible non-first-order kinetics of hyperpolarized [1-(13)C] pyruvate employing a system of differential equations that agrees with the principle of conservation of mass

  6. Recent {sup 3}He radio frequency heating experiments on JET

    Energy Technology Data Exchange (ETDEWEB)

    Van Eester, D. [Association Euratom-Belgian State, LPP-ERM/KMS, TEC, Brussels (Belgium); Imbeaux, F.; Joffrin, E. [Association Euratom-CEA Cadarache, 13 - Saint-Paul-lez-Durance (France)] [and others

    2003-07-01

    Various ITER relevant experiments using {sup 3}He in a majority D plasma were performed in the recent JET campaigns. Two types can be distinguished: dedicated studies of the various RF heating scenarios which rely on the presence of {sup 3}He, and physics studies using RF heating as a working tool to provide a tunable heat source. As the success of a number of these experiments depended on the capability to keep the {sup 3}He concentration fixed, real time control of the {sup 3}He concentration was developed and used. This paper presents a brief overview of the results obtained, zooms in on some of the more interesting recent findings and discusses some of the theoretical background. (authors)

  7. One-body density matrix and the momentum density in 4He and 3He

    International Nuclear Information System (INIS)

    Whitlock, P.A.; Panoff, R.M.

    1984-01-01

    The one-body density matrix and the momentum density for liquid and solid 4 He, determined from Green's Function Monte Carlo calculations using the HFDHE2 pair potential, are described. Values for the condensate fraction and the kinetic energy derived from these calculations are given and compared to recent experimental results. Preliminary results from variational Monte Carlo calculations on n(r) and n(k) for liquid 3 He are also reported

  8. Vantage TitanTM 3T 3-tesla MRI system with enhanced serviceability and comfort

    International Nuclear Information System (INIS)

    Kanazawa, Hitoshi; Okamoto, Kazuya; Yamamoto, Takao

    2011-01-01

    Since 3-tesla magnetic resonance imaging (MRI) systems appeared on the market, in addition to their clinical usefulness a variety of issues have been pointed out in the clinical setting. The 3-tesla MRI system has therefore gained a reputation as a difficult system suitable only for hospital facilities including university hospitals that specialize in medical research. To rectify this situation, Toshiba Medical Systems Corporation has developed the Vantage Titan TM 3T, which is expected to not only improve the MRI examination environment, but also to be applicable to patients with claustrophobia and those with large physiques for whom MRI examination has not been appropriate until now, while maintaining the clinical usefulness of the 3-tesla MRI system. The Vantage Titan 3T system also incorporates the Pianissimo TM noise reduction mechanism, which has already been introduced in our 1.5-tesla MRI system and has been highly evaluated by the market. This reduces the stress of patients by providing a quieter and more open examination environment compared with conventional MRI systems. (author)

  9. Measurement of fast minority /sub 3/He/sup + +/ energy distribution during ICRF heating

    Science.gov (United States)

    Post, D.E. Jr.; Grisham, L.R.; Medley, S.S.

    A method and means for measuring the fast /sub 3/He/sup + +/ distribution during /sub 3/He/sup + +/ minority Ion Cyclotron Resonance Frequency (ICRF) heating is disclosed. The present invention involves the use of 10 to 100 keV beams of neutral helium atoms to neutralize the fast /sub 3/He/sup + +/ ions in a heated plasma by double charge exchange (/sub 3/He/sup + +/ + /sub 4/He/sup 0/ ..-->.. /sub 3/He/sup 0/ + /sub 4/He/sup + +/). The neutralized fast /sub 3/He/sup 0/ atoms then escape from the hot plasma confined by a magnetic field and are detected by conventional neutral particle analyzing means. This technique permits the effectiveness of the coupling of the ion cyclotron waves to the /sub 3/He/sup + +/ minority ions to be accurately measured. The present invention is particularly adapted for use in evaluating the effectiveness of the intermediate coupling between the RF heating and the /sub 3/He/sup + +/ in an energetic toroidal plasma.

  10. Dysfunctional Hyperpolarization-Activated Cyclic Nucleotide-gated Ion Channels in Cardiac Diseases

    Directory of Open Access Journals (Sweden)

    Xiaoqi Zhao

    Full Text Available Abstract Hyperpolarization-activated cyclic nucleotide-gated (HCN channels are reverse voltage-dependent, and their activation depends on the hyperpolarization of the membrane and may be directly or indirectly regulated by the cyclic adenosine monophosphate (cAMP or other signal-transduction cascades. The distribution, quantity and activation states of HCN channels differ in tissues throughout the body. Evidence exhibits that HCN channels play critical roles in the generation and conduction of the electrical impulse and the physiopathological process of some cardiac diseases. They may constitute promising drug targets in the treatment of these cardiac diseases. Pharmacological treatment targeting HCN channels is of benefit to these cardiac conditions.

  11. MRI of 'brain death'

    Energy Technology Data Exchange (ETDEWEB)

    Nishino, Shigeki; Itoh, Takahiko; Tuchida, Shohei; Kinugasa, Kazushi; Asari, Shoji; Nishimoto, Akira (Okayama Univ. (Japan). School of Medicine); Sanou, Kazuo

    1990-12-01

    Magnetic resonance imaging (MRI) was undertaken for two patients who suffered from severe cerebrovascular diseases and were clinically brain dead. The MRI system we used was Resona (Yokogawa Medical Systems, superconductive system 0.5 T) and the CT apparatus was Toshiba TCT-300. Initial CT and MRI were undertaken as soon as possible after admission, and repeated sequentially. After diagnosis of brain death, we performed angiography to determine cerebral circulatory arrest, and MRI obtained at the same time was compared with the angiogram and CT. Case 1 was a 77-year-old man who was admitted in an unconscious state. CT and MRI on the second day after hospitalization revealed cerebellar infarction. He was diagnosed as brain dead on day 4. Case 2 was a 35-year-old man. When he was transferred to our hospital, he was in cardiorespiratory arrested. Cardiac resuscitation was successful but no spontaneous respiration appeared. CT and MRI on admission revealed right intracerebral hemorrhage. Angiography revealed cessation of contrast medium in intracranial vessels in both of the patients. We found no 'flow signal void sign' in the bilateral internal carotid and basilar arteries on MRI images in both cases after brain death. MRI, showing us the anatomical changes of the brain, clearly revealed brain herniations, even though only nuclear findings of 'brain tamponade' were seen on CT. But in Case 1, we could not see the infarct lesions in the cerebellum on MR images obtained after brain death. This phenomenon was caused by the whole brain ischemia masking the initial ischemic lesions. We concluded that MRI was useful not only the anatomical display of lesions and brain herniation with high contrast resolution but for obtaining information on cerebral circulation of brain death. (author).

  12. Development of Laser-Polarized Noble Gas Magnetic Resonance Imaging (MRI) Technology

    Science.gov (United States)

    Walsworth, Ronald L.

    2004-01-01

    We are developing technology for laser-polarized noble gas nuclear magnetic resonance (NMR), with the aim of enabling it as a novel biomedical imaging tool for ground-based and eventually space-based application. This emerging multidisciplinary technology enables high-resolution gas-space magnetic resonance imaging (MRI)-e.g., of lung ventilation, perfusion, and gas-exchange. In addition, laser-polarized noble gases (3He and 1BXe) do not require a large magnetic field for sensitive NMR detection, opening the door to practical MRI with novel, open-access magnet designs at very low magnetic fields (and hence in confined spaces). We are pursuing two specific aims in this technology development program. The first aim is to develop an open-access, low-field (less than 0.01 T) instrument for MRI studies of human gas inhalation as a function of subject orientation, and the second aim is to develop functional imaging of the lung using laser-polarized He-3 and Xe-129.

  13. H-, He-like recombination spectra - II. l-changing collisions for He Rydberg states

    Science.gov (United States)

    Guzmán, F.; Badnell, N. R.; Williams, R. J. R.; van Hoof, P. A. M.; Chatzikos, M.; Ferland, G. J.

    2017-01-01

    Cosmological models can be constrained by determining primordial abundances. Accurate predictions of the He I spectrum are needed to determine the primordial helium abundance to a precision of big bang nucleosynthesis models. Theoretical line emissivities at least this accurate are needed if this precision is to be achieved. In the first paper of this series, which focused on H I, we showed that differences in l-changing collisional rate coefficients predicted by three different theories can translate into 10 per cent changes in predictions for H I spectra. Here, we consider the more complicated case of He atoms, where low-l subshells are not energy degenerate. A criterion for deciding when the energy separation between l subshells is small enough to apply energy-degenerate collisional theories is given. Moreover, for certain conditions, the Bethe approximation originally proposed by Pengelly & Seaton is not sufficiently accurate. We introduce a simple modification of this theory which leads to rate coefficients which agree well with those obtained from pure quantal calculations using the approach of Vrinceanu et al. We show that the l-changing rate coefficients from the different theoretical approaches lead to differences of ˜10 per cent in He I emissivities in simulations of H II regions using spectral code CLOUDY.

  14. Surface study of liquid 3He using surface state electrons

    International Nuclear Information System (INIS)

    Shirahama, K.; Ito, S.; Suto, H.; Kono, K.

    1995-01-01

    We have measured the mobility of surface state electrons (SSE) on liquid 3 He, μ 3 , aiming to study the elementary surface excitations of the Fermi liquid. A gradual increase of μ 3 below 300 mK is attributed to the scattering of electrons by ripplons. Ripplons do exist in 3 He down to 100 mK. We observe an abrupt decrease of μ 3 , due to the transition to the Wigner solid (WS). The dependences of the WS conductivity and mobility on temperature and magnetic field differ from the SSE behavior on liquid 4 He

  15. Apparent CFC and 3H/ 3He age differences in water from Floridan Aquifer springs

    Science.gov (United States)

    Happell, James D.; Opsahl, Stephen; Top, Zafer; Chanton, Jeffrey P.

    2006-03-01

    The apparent CFC-11, -12 and -113 ages of Upper Floridan Aquifer water discharged from 31 springs located in Florida and Georgia ranged from 11 to 44 years when samples were collected in 2002 and 2003. Apparent 3H/ 3He ages in these springs ranged from 12 to 66 years. Some of the springs sampled did not yield valid CFC ages because one or more of the CFCs were contaminated by non-atmospheric sources. Of the 31 springs sampled, six were contaminated with all three CFCs and nine were contaminated with one or two CFCs. Of the remaining 16 springs, the CFC distributions of four could be modeled assuming a single source of water, and 11 were best modeled by assuming two sources of water, with one of the water sources >60 years old. The CFC and 3H/ 3He apparent ages and the simple mixing models applied to these ages suggest that past impacts to the water quality of water recharging the sampled springs may take anywhere from 0 to ˜60 years or more to appear in the discharging spring water. In 27 springs where both 3H/ 3He ages and CFC ages were available, five springs gave similar results between the two techniques, while in the other 22 cases the 3H/ 3He apparent ages were 8-40 years greater than the CFC ages. Large excesses of 4He were observed in many of the springs, consistent with a source of older water. This older water may also carry an additional and unaccounted for source of 3He, which may be responsible for the greater 3H/ 3He ages relative to the CFC ages. We believe that the large excess 3He and 4He values and apparent age differences are related to regional climate variations because our samples were obtained at the end of a 4-year drought.

  16. A Technique for Generating Volumetric Cine MRI (VC-MRI)

    Science.gov (United States)

    Harris, Wendy; Ren, Lei; Cai, Jing; Zhang, You; Chang, Zheng; Yin, Fang-Fang

    2016-01-01

    Purpose To develop a technique to generate on-board volumetric-cine MRI (VC-MRI) using patient prior images, motion modeling and on-board 2D-cine MRI. Methods One phase of a 4D-MRI acquired during patient simulation is used as patient prior images. 3 major respiratory deformation patterns of the patient are extracted from 4D-MRI based on principal-component-analysis. The on-board VC-MRI at any instant is considered as a deformation of the prior MRI. The deformation field is represented as a linear combination of the 3 major deformation patterns. The coefficients of the deformation patterns are solved by the data fidelity constraint using the acquired on-board single 2D-cine MRI. The method was evaluated using both XCAT simulation of lung cancer patients and MRI data from four real liver cancer patients. The accuracy of the estimated VC-MRI was quantitatively evaluated using Volume-Percent-Difference(VPD), Center-of-Mass-Shift(COMS), and target tracking errors. Effects of acquisition orientation, region-of-interest(ROI) selection, patient breathing pattern change and noise on the estimation accuracy were also evaluated. Results Image subtraction of ground-truth with estimated on-board VC-MRI shows fewer differences than image subtraction of ground-truth with prior image. Agreement between profiles in the estimated and ground-truth VC-MRI was achieved with less than 6% error for both XCAT and patient data. Among all XCAT scenarios, the VPD between ground-truth and estimated lesion volumes was on average 8.43±1.52% and the COMS was on average 0.93±0.58mm across all time-steps for estimation based on the ROI region in the sagittal cine images. Matching to ROI in the sagittal view achieved better accuracy when there was substantial breathing pattern change. The technique was robust against noise levels up to SNR=20. For patient data, average tracking errors were less than 2 mm in all directions for all patients. Conclusions Preliminary studies demonstrated the

  17. Acute hypertensive stress imaged by cardiac hyperpolarized [1-C]pyruvate magnetic resonance

    DEFF Research Database (Denmark)

    Tougaard, Rasmus Stilling; Hansen, Esben Søvsø Szocska; Laustsen, Christoffer

    2018-01-01

    PURPOSE: Deranged metabolism is now recognized as a key causal factor in a variety of heart diseases, and is being studied extensively. However, invasive methods may alter metabolism, and conventional imaging techniques measure tracer uptake but not downstream metabolism. These challenges may...... be overcome by hyperpolarized MR, a noninvasive technique currently crossing the threshold into human trials. The aim of this study was to image metabolic changes in the heart in response to endogastric glucose bolus and to acute hypertension. METHODS: Five postprandial pigs were scanned with hyperpolarized.......008) and ejection fraction decreased from 54 ± 2% to 47 ± 6% (P = 0.03) The hemodynamic changes were accompanied by increases in the hyperpolarized [1-13C]pyruvate MR derived ratios of lactate/alanine (from 0.58 ± 0.13 to 0.78 ± 0.06, P = 0.03) and bicarbonate/alanine (from 0.55 ± 0.12 to 0.91 ± 0.14, P = 0...

  18. X-radiation effect on the hyperpolarization of cells, the adeninenucleotide content and the distribution of sodium and potassium ions

    Energy Technology Data Exchange (ETDEWEB)

    Frol' kis, V V [Akademiya Meditsinskikh Nauk Ukrainskoj SSR, Kiev. Inst. Gerontologii

    1975-03-01

    X-radiation prevents the progress of hyperpolarization of muscle and liver cells caused by hormones (estradioldipropyonate, deoxycorticosteron-acetate and insulin) and by the loss of blood. X-radiation offsets the redistribution of K/sup +/ and Na/sup +/ ions caused by hyperpolarization and does not change the level of ATP, ADP, CP and Pi. X-radiation is suggested to affect the hyperpolarization and the ionic shifts via the system of protein biosynthesis.

  19. Terrestrial cosmogenic 3He: where are we 30 years after its discovery?

    Science.gov (United States)

    Blard, Pierre-Henri; Pik, Raphaël; Farley, Kenneth A.; Lavé, Jérôme; Marrocchi, Yves

    2016-04-01

    It is now 30 years since cosmogenic 3He has been detected for the first time in a terrestrial sample (Kurz, 1986). 3He is now a widely used geochemical tool in many fields of Earth sciences: volcanology, tectonics, paleoclimatology. 3He has the advantage to have a high "production rate" to "detection limit" ratio, allowing surfaces as young as hundred of years to be dated. Although its nuclear stability implies several limitations, it moreover represents a useful alternative to 10Be in mafic environments. This contribution is a review of the progresses that have been accomplished since this discovery, and discuss strategies to improve both the accuracy and the precision of this geochronometer. 1) Measurement of cosmogenic 3He Correction of magmatic 3He. To estimate the non-cosmogenic magmatic 3He, Kurz (1986) invented a two steps method involving crushing of phenocrysts (to analyze the isotopic ratio of the magmatic component), followed by a subsequent melting of the sample, to extract the remaining components, including the cosmogenic 3He: 3Hec = 3Hemelt -4Hemelt x (3He/4He)magmatic (1) Several studies suggested that the preliminary crushing may induce a loss of cosmogenic 3He (Hilton et al., 1993; Yokochi et al., 2005; Blard et al., 2006), implying an underestimate of the cosmogenic 3He measurement. However, subsequent work did not replicate these observations (Blard et al., 2008; Goerhing et al., 2010), suggesting an influence of the used apparatus. An isochron method (by directly melting several phenocrysts aliquots) is an alternative to avoid the preliminary crushing step (Blard and Pik, 2008). Atmospheric contamination. Protin et al. (in press) provides robust evidences for a large and irreversible contamination of atmospheric helium on silicate surfaces. This unexpected behavior may reconcile the contrasted observations about the amplitude of crushing loss. This undesirable atmospheric contamination is negligible if grain fractions smaller than 150 mm are

  20. Ionic channels and membrane hyperpolarization in human macrophages

    NARCIS (Netherlands)

    Ince, C.; van Duijn, B.; Ypey, D. L.; van Bavel, E.; Weidema, F.; Leijh, P. C.

    1987-01-01

    Microelectrode impalement of human macrophages evokes a transient hyperpolarizing response (HR) of the membrane potential. This HR was found to be dependent on the extracellular concentration of K+ but not on that of Na+ or Cl-. It was not influenced by low temperature (12 degrees C) or by 0.2 mM

  1. Experimental investigation and numerical simulation of 3He gas diffusion in simple geometries: implications for analytical models of 3He MR lung morphometry.

    Science.gov (United States)

    Parra-Robles, J; Ajraoui, S; Deppe, M H; Parnell, S R; Wild, J M

    2010-06-01

    Models of lung acinar geometry have been proposed to analytically describe the diffusion of (3)He in the lung (as measured with pulsed gradient spin echo (PGSE) methods) as a possible means of characterizing lung microstructure from measurement of the (3)He ADC. In this work, major limitations in these analytical models are highlighted in simple diffusion weighted experiments with (3)He in cylindrical models of known geometry. The findings are substantiated with numerical simulations based on the same geometry using finite difference representation of the Bloch-Torrey equation. The validity of the existing "cylinder model" is discussed in terms of the physical diffusion regimes experienced and the basic reliance of the cylinder model and other ADC-based approaches on a Gaussian diffusion behaviour is highlighted. The results presented here demonstrate that physical assumptions of the cylinder model are not valid for large diffusion gradient strengths (above approximately 15 mT/m), which are commonly used for (3)He ADC measurements in human lungs. (c) 2010 Elsevier Inc. All rights reserved.

  2. The πHe3H3 coupling constant estimation using the Chew-Low equation

    International Nuclear Information System (INIS)

    Mach, R.; Nichitiu, F.

    1976-01-01

    A semi-phenomenological analysis of the π +- He 3 elastic scattering at 98, 120, 135 and 156 Mev is presented. An information of the πHe 3 H 3 coupling constant using the Chew-Low plot for the P 33 partial wave is obtained. (author)

  3. The πHe3H3 coupling constant estimation using the Chew-Low equation

    International Nuclear Information System (INIS)

    Mach, R.; Nichitiu, F.

    1975-01-01

    In this paper it is presented an estimation of the πHe 3 H 3 coupling constant using the Chew-Low equation and a semi-phenomenological analysis of the π -+ He 3 elastic differential cross sections at 98, 120, 135 and 156 MeV

  4. Mechanisms of hyperpolarization in regenerated mature motor axons in cat

    DEFF Research Database (Denmark)

    Moldovan, Mihai; Krarup, Christian

    2004-01-01

    We found persistent abnormalities in the recovery of membrane excitability in long-term regenerated motor nerve fibres in the cat as indicated in the companion paper. These abnormalities could partly be explained by membrane hyperpolarization. To further investigate this possibility, we compared...... the changes in excitability in control nerves and long-term regenerated cat nerves (3-5 years after tibial nerve crush) during manoeuvres known to alter axonal membrane Na(+)-K(+) pump function: polarization, cooling to 20 degrees C, reperfusion after 10 min ischaemia, and up to 60 s of repetitive stimulation...

  5. Development of a 3He nuclear spin flip system on an in-situ SEOP 3He spin filter and demonstration for a neutron reflectometer and magnetic imaging technique

    International Nuclear Information System (INIS)

    Hayashida, H; Kira, H; Miyata, N; Akutsu, K; Mizusawa, M; Parker, J D; Matsumoto, Y; Oku, T; Sakai, K; Hiroi, K; Shinohara, T; Takeda, M; Yamazaki, D; Oikawa, K; Harada, M; Ino, T; Imagawa, T; Ohkawara, M; Ohoyama, K; Kakurai, K

    2016-01-01

    We have been developing a 3 He neutron spin filter (NSF) using the spin exchange optical pumping (SEOP) technique. The 3 He NSF provides a high-energy polarized neutron beam with large beam size. Moreover the 3 He NSF can work as a π-flipper for a polarized neutron beam by flipping the 3 He nuclear spin using a nuclear magnetic resonance (NMR) technique. For NMR with the in-situ SEOP technique, the polarization of the laser must be reversed simultaneously because a non-reversed laser reduces the polarization of the spin-flipped 3 He. To change the polarity of the laser, a half-wavelength plate was installed. The rotation angle of the half-wavelength plate was optimized, and a polarization of 97% was obtained for the circularly polarized laser. The 3 He polarization reached 70% and was stable over one week. A demonstration of the 3 He nuclear spin flip system was performed at the polarized neutron reflectometer SHARAKU (BL17) and NOBORU (BL10) at J-PARC. Off-specular measurement from a magnetic Fe/Cr thin film and magnetic imaging of a magnetic steel sheet were performed at BL17 and BL10, respectively. (paper)

  6. Magnetic Resonance Angiography in the Pig using Hyperpolarized Water

    DEFF Research Database (Denmark)

    Lipsø, Hans Kasper Wigh; Bowen, Sean; Laustsen, Christoffer

    , the magnetization achievable with hyperpolarized water is superior to other nuclei. Methods A 1 mL sample of 50% water and 50% glycerol with 30 mM TEMPO is polarized in a Spinlab (GE Healthcare) at 5 T, 0.9 K, 139.9 GHz for an hour. The sample is rapidly dissolved in 16 mL deoxygenized dissolution medium (DM......Introduction Magnetic Resonance Angiography (MRA) is an important tool in diagnostics of medical conditions such as emboli, stenosis and aneurysms. Sub-millimetre resolution can be obtained with proton imaging, and further optimization can be obtained with Gd-based blood pool agents1. However......, the acquisition time is several minutes, and conventional MRA methods thus fail to image within a single respiration or heartbeat and therefore suffers from motion artefacts. We demonstrate that hyperpolarized (HP) water can be used as an imaging agent to provide subsecond angiographies in pigs. Previous work...

  7. Assessment of the cervical spine denticulate ligament using MRI volumetric sequence: Comparison between 1.5 Tesla and 3.0 Tesla.

    Science.gov (United States)

    Seragioli, Rafael; Simao, Marcelo Novelino; Simao, Gustavo Novelino; Herrero, Carlos Fernando P S; Nogueira-Barbosa, Marcello H

    2018-03-01

    Denticulate ligaments (DLs) are pial extensions on each side of the spinal cord, comprising about 20 to 21 pairs of fibrous structures connecting the dura mater to the spinal cord. These ligaments are significant anatomical landmarks in the surgical approach to intradural structures. To our knowledge, there is no previous study on the detection of DLs using MRI. After IRB approval, we retrospectively evaluated 116 consecutive MRI scans of the cervical spine, using the volumetric sequence 3D COSMIC, 65 and 51 studies with 1.5T and 3.0T respectively. We did not include trauma and tumor cases. Two independent radiologists assessed the detection of cervical spine DLs independently and blinded for each cervical vertebral level. We compared the frequency of detection of these ligaments in 1.5 Tesla and 3.0 Tesla MRI using Fisher exact test considering P<0.05 as significant. We evaluated interobserver agreement with Kappa coefficient. We observed high detection frequency of the cervical spine DLs using both 1.5T (70 to 91%) and 3.0T (68 to 98%). We found no statistically significant difference in the detection frequency of ligaments between the 1.5T and 3.0T MRI in all vertebral levels. Using 3.0T, radiologists identified ligaments better in higher vertebral levels than for lower cervical levels (P=0.0003). Interobserver agreement on the identification of DL was poor both for 1.5T (k=0.3744; CI 95% 0.28-0.46) and 3.0T (k=0.3044; CI 95% 0.18-0.42) MRI. Radiologists identified most of the cervical DLs using volumetric MRI acquisition. Our results suggest 1.5T and 3.0T MRI performed similarly in the detection of DLs. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  8. Quasi-free and sequential processes in the 9Be(3He,αα)4He reaction at 2,8 MeV

    International Nuclear Information System (INIS)

    Barbarino, S.; Lattuada, M.; Riggi, F.; Spitaleri, C.; Vinciguerra, D.

    1979-01-01

    The quasi-free contribution to the 9 Be( 3 He,αα) 4 He reaction at low incident energy is studied under various detection configurations. The measurements performed at quasi-free angles (symmetrical and non-symmetrical configurations) furter confirm that a large region in the energy spectra is dominated by the quasi-free 5 He( 3 He,α) 4 He process. From a comparison of these results with those taken at symmetrical angles where the minimum accepted momentum of the spectator is around 70 MeV/c, the conclusion is drawn that no significant distortion is introduced by the sequential peak tails in the deduced 5 He- 4 He momentum distribution

  9. Spin-polarized 3He nuclear targets and metastable 4He atoms by optical pumping with a tunable, Nd:YAP laser

    International Nuclear Information System (INIS)

    Bohler, C.L.; Schearer, L.D.; Leduc, M.; Nacher, P.J.; Zachorowski, L.; Milner, R.G.; McKeown, R.D.; Woodward, C.E.

    1988-01-01

    Several Nd:YAP lasers were constructed which could be broadly tuned in the 1083-nm region which includes the helium 2 3 S-2 3 P transition, using a Lyot filter and thin, uncoated etalons within the laser cavity. 1 W of power could be extracted at 1083 nm through a 1% transmitting output coupler. This laser beam was used to optically pump metastable 4 He and 3 He 2 3 S helium atoms in a weak discharge cell, spin polarizing the metastable ensemble. In a 3 He cell the polarization is transferred to the nuclear spin system. A 3 He target cell at 0.3 Torr was polarized to 52% in a few minutes. We describe the application of this system to the design of polarized targets for experiments in nuclear physics

  10. Spin structure of the 3He from the dd → 3Hen reaction

    International Nuclear Information System (INIS)

    Ladygin, V.P.; Ladygina, N.B.

    1995-01-01

    The polarization observables in the reaction dd → 3 Hen are considered. Their high sensitivity to the 3 He wave function at short distances is shown. Using of both polarized target and beam allows to extend sufficiently the number of possible experiments and to separate 3 He structure from the reaction mechanisms using different relative orientations of initial deuteron spins. 27 refs., 5 figs

  11. Small objects in superfluid 3He

    International Nuclear Information System (INIS)

    Rainer, D.; Vuorio, M.

    1977-02-01

    Distortions in the superfluid order parameter around a small object in 3 He are calculated together with the supercurrents and the angular momentum induced by it in the liquid. The forces acting on the impurity by the liquid texture structure are also considered. (author)

  12. A polarized solid {sup 3}He target for neutron transmission experiments

    Energy Technology Data Exchange (ETDEWEB)

    Keith, C.D. [North Carolina State Univ., Raleigh, NC (United States)]|[Triangle Universities Nuclear Laboratory, Durham, NC 27708-0308 (United States); Gould, C.R. [North Carolina State Univ., Raleigh, NC (United States)]|[Triangle Universities Nuclear Laboratory, Durham, NC 27708-0308 (United States); Haase, D.G. [North Carolina State Univ., Raleigh, NC (United States)]|[Triangle Universities Nuclear Laboratory, Durham, NC 27708-0308 (United States); Huffman, P.R. [Duke University, Durham, NC 27708-0308 (United States)]|[Triangle Universities Nuclear Laboratory, Durham, NC 27708-0308 (United States); Roberson, N.R. [Duke University, Durham, NC 27708-0308 (United States)]|[Triangle Universities Nuclear Laboratory, Durham, NC 27708-0308 (United States); Seely, M.L. [North Carolina State Univ., Raleigh, NC (United States)]|[Triangle Universities Nuclear Laboratory, Durham, NC 27708-0308 (United States); Tornow, W. [Duke University, Durham, NC 27708-0308 (United States)]|[Triangle Universities Nuclear Laboratory, Durham, NC 27708-0308 (United States); Wilburn, W.S. [Duke University, Durham, NC 27708-0308 (United States)]|[Triangle Universities Nuclear Laboratory, Durham, NC 27708-0308 (United States)

    1995-04-01

    We describe the construction and operation of a solid {sup 3}He polarized nuclear target which we have used for measurements of the spin dependence of the n-{sup 3}He interaction at MeV energies. The target, which contains 0.4 mole of {sup 3}He was polarized to 38% at 12 mK in a field of 7 T. The target is suitable for nuclear physics measurements which are insensitive to the large magnetic field and produce beam heating of tenths of microwatts.We discuss refinements and paths to improved solid {sup 3}He targets at higher polarizations and lower fields. ((orig.)).

  13. Accelerating volumetric cine MRI (VC-MRI) using undersampling for real-time 3D target localization/tracking in radiation therapy: a feasibility study

    Science.gov (United States)

    Harris, Wendy; Yin, Fang-Fang; Wang, Chunhao; Zhang, You; Cai, Jing; Ren, Lei

    2018-01-01

    Purpose. To accelerate volumetric cine MRI (VC-MRI) using undersampled 2D-cine MRI to provide real-time 3D guidance for gating/target tracking in radiotherapy. Methods. 4D-MRI is acquired during patient simulation. One phase of the prior 4D-MRI is selected as the prior images, designated as MRIprior. The on-board VC-MRI at each time-step is considered a deformation of the MRIprior. The deformation field map is represented as a linear combination of the motion components extracted by principal component analysis from the prior 4D-MRI. The weighting coefficients of the motion components are solved by matching the corresponding 2D-slice of the VC-MRI with the on-board undersampled 2D-cine MRI acquired. Undersampled Cartesian and radial k-space acquisition strategies were investigated. The effects of k-space sampling percentage (SP) and distribution, tumor sizes and noise on the VC-MRI estimation were studied. The VC-MRI estimation was evaluated using XCAT simulation of lung cancer patients and data from liver cancer patients. Volume percent difference (VPD) and Center of Mass Shift (COMS) of the tumor volumes and tumor tracking errors were calculated. Results. For XCAT, VPD/COMS were 11.93  ±  2.37%/0.90  ±  0.27 mm and 11.53  ±  1.47%/0.85  ±  0.20 mm among all scenarios with Cartesian sampling (SP  =  10%) and radial sampling (21 spokes, SP  =  5.2%), respectively. When tumor size decreased, higher sampling rate achieved more accurate VC-MRI than lower sampling rate. VC-MRI was robust against noise levels up to SNR  =  20. For patient data, the tumor tracking errors in superior-inferior, anterior-posterior and lateral (LAT) directions were 0.46  ±  0.20 mm, 0.56  ±  0.17 mm and 0.23  ±  0.16 mm, respectively, for Cartesian-based sampling with SP  =  20% and 0.60  ±  0.19 mm, 0.56  ±  0.22 mm and 0.42  ±  0.15 mm, respectively, for

  14. HE3 outgassing from four working palladium and uranium beds

    International Nuclear Information System (INIS)

    Souers, P. C.; Coronado, P. R.; Fearon, F. M.; Garza, R. G.; Shaw , J. F.; Stump, R. K.; Tsugawa, R. T.

    1988-01-01

    The He 3 output from two palladium and two uranium beds storing T 2 and D-T was studied as a function of time. Three of the beds were started new and watched for a year; the fourth bed was twelve years old. All four were beds used in routine tritium handling. Initial stoichiometries were PdT/sub 0.3/ and UT/sub 0.7/ so that both operated at similar 1 to 130 kPa pressures. The He 3 from palladium ranged from the 0.002 mo1% lower level of sensitivity to 0.01% for PdT 2 at one year of age. The UT system showed 0.1% He 3 at 4 to 62 days and 0.1 to 10% at longer times, with the first cuts being high in He 3 . The palladium bed with 95 to 97% pure T 2 enriches the output to as high as 97 to 99%. 9 refs., 1 fig., 2 tabs

  15. Hyperpolarized 13C MR Markers of Renal Tumor Aggressiveness

    Science.gov (United States)

    2015-12-01

    production in the presence of oxygen (11, 12). Increased glycolysis facilitates the uptake and incorporation of nutrients and biomass needed for cell... shell coil; (d) Hyperpolarized lactate images overlaid on T2 weighted anatomical images, clearly depicting the tumor voxels (Figure 5). As shown in

  16. Hyperpolarized C-13 MRS Cardiac Metabolism Studies in Pigs

    DEFF Research Database (Denmark)

    Giovannetti, G.; Hartwig, V.; Frijia, F.

    2012-01-01

    Cardiac metabolism assessment with hyperpolarized 13C magnetic resonance spectroscopy in pig models requires the design of dedicated coils capable of providing large field of view with high signal-to-noise ratio (SNR) data. This work presents a comparison between a commercial 13C quadrature...

  17. Ab initio calculations of 3H(d,n)4He fusion

    International Nuclear Information System (INIS)

    Navratil, Petr; Quaglioni, Sofia

    2012-01-01

    We build a new ab initio many-body approach capable of describing simultaneously both bound and scattering states in light nuclei, by combining the resonating-group method with the ab initio no-core shell model. In this way, we complement a microscopic-cluster technique with the use of realistic interactions, and a microscopic and consistent description of the nucleon clusters. We will present the first results of the d- 3 H and d- 3 He fusion calculation obtained within our ab initio approach. We will also discuss our d- 4 He, 3 H- 4 He and 3 H- 3 H scattering calculations and the outline of the extension of the formalism to include three-cluster final states with the goal to calculate the 3 H( 3 H,2n) 4 He cross section

  18. Imaging Human Brain Perfusion with Inhaled Hyperpolarized 129Xe MR Imaging.

    Science.gov (United States)

    Rao, Madhwesha R; Stewart, Neil J; Griffiths, Paul D; Norquay, Graham; Wild, Jim M

    2018-02-01

    Purpose To evaluate the feasibility of directly imaging perfusion of human brain tissue by using magnetic resonance (MR) imaging with inhaled hyperpolarized xenon 129 ( 129 Xe). Materials and Methods In vivo imaging with 129 Xe was performed in three healthy participants. The combination of a high-yield spin-exchange optical pumping 129 Xe polarizer, custom-built radiofrequency coils, and an optimized gradient-echo MR imaging protocol was used to achieve signal sensitivity sufficient to directly image hyperpolarized 129 Xe dissolved in the human brain. Conventional T1-weighted proton (hydrogen 1 [ 1 H]) images and perfusion images by using arterial spin labeling were obtained for comparison. Results Images of 129 Xe uptake were obtained with a signal-to-noise ratio of 31 ± 9 and demonstrated structural similarities to the gray matter distribution on conventional T1-weighted 1 H images and to perfusion images from arterial spin labeling. Conclusion Hyperpolarized 129 Xe MR imaging is an injection-free means of imaging the perfusion of cerebral tissue. The proposed method images the uptake of inhaled xenon gas to the extravascular brain tissue compartment across the intact blood-brain barrier. This level of sensitivity is not readily available with contemporary MR imaging methods. © RSNA, 2017.

  19. Biochemical and structural analysis of the hyperpolarization-activated K(+) channel MVP.

    Science.gov (United States)

    Randich, Amelia M; Cuello, Luis G; Wanderling, Sherry S; Perozo, Eduardo

    2014-03-18

    In contrast to the majority of voltage-gated ion channels, hyperpolarization-activated channels remain closed at depolarizing potentials and are activated at hyperpolarizing potentials. The basis for this reverse polarity is thought to be a result of differences in the way the voltage-sensing domain (VSD) couples to the pore domain. In the absence of structural data, the molecular mechanism of this reverse polarity coupling remains poorly characterized. Here we report the characterization of the structure and local dynamics of the closed activation gate (lower S6 region) of MVP, a hyperpolarization-activated potassium channel from Methanococcus jannaschii, by electron paramagnetic resonance (EPR) spectroscopy. We show that a codon-optimized version of MVP has high expression levels in Escherichia coli, is purified as a stable tetramer, and exhibits expected voltage-dependent activity when reconstituted in liposomes. EPR analysis of the mid to lower S6 region revealed positions exhibiting strong spin-spin coupling, indicating that the activation gate of MVP is closed at 0 mV. A comparison of local environmental parameters along the activation gate for MVP and KcsA indicates that MVP adopts a different closed conformation. These structural details set the stage for future evaluations of reverse electromechanical coupling in MVP.

  20. Biochemical and Structural Analysis of the Hyperpolarization-Activated K+ Channel MVP

    Science.gov (United States)

    2015-01-01

    In contrast to the majority of voltage-gated ion channels, hyperpolarization-activated channels remain closed at depolarizing potentials and are activated at hyperpolarizing potentials. The basis for this reverse polarity is thought to be a result of differences in the way the voltage-sensing domain (VSD) couples to the pore domain. In the absence of structural data, the molecular mechanism of this reverse polarity coupling remains poorly characterized. Here we report the characterization of the structure and local dynamics of the closed activation gate (lower S6 region) of MVP, a hyperpolarization-activated potassium channel from Methanococcus jannaschii, by electron paramagnetic resonance (EPR) spectroscopy. We show that a codon-optimized version of MVP has high expression levels in Escherichia coli, is purified as a stable tetramer, and exhibits expected voltage-dependent activity when reconstituted in liposomes. EPR analysis of the mid to lower S6 region revealed positions exhibiting strong spin–spin coupling, indicating that the activation gate of MVP is closed at 0 mV. A comparison of local environmental parameters along the activation gate for MVP and KcsA indicates that MVP adopts a different closed conformation. These structural details set the stage for future evaluations of reverse electromechanical coupling in MVP. PMID:24490868

  1. Progress in Polarized 3He Ion Source at RCNP

    International Nuclear Information System (INIS)

    Tanaka, M.; Takahashi, Y.; Shimoda, T.; Yasui, S.; Yosoi, M.; Takahisa, K.; Shimakura, N.; Plis, Yu. A.; Donets, E. D.

    2007-01-01

    A long history on the polarized 3He ion source developed at RCNP is presented. We started with an 'OPPIS' (Optical Pumping Polarized Ion Source) and later found the fundamental difficulties in the OPPIS. To overcome them an 'EPPIS' (Electron Pumping Polarized Ion Source) was proposed and its validity was experimentally proven. However, a serious technical disadvantage was also found in the EPPIS. To avoid this disadvantage we proposed a new concept, 'SEPIS' (Spin Exchange Polarized Ion Source), which uses an enhanced spin-exchange cross section theoretically expected at low 3He+ incident energies in the 3He+ + Rb system. Next, we describe the present status of the SEPIS development: construction of a bench test device allowing the measurements of not only the spin-exchange cross sections σse but also the electron capture cross sections σec for the 3He+ + Rb system. The latest experimental data on σec are presented and compared with other previous experimental data and the theoretical calculations.Finally, a design study of the SEPIS for practical use in nuclear (cyclotron) and particle physics (synchrotron) is shortly mentioned

  2. Study on the mechanism of the 3He+p→p+p+d reaction at 3He momentum of 5 GeV/c

    International Nuclear Information System (INIS)

    Blinov, A.V.; Chuvilo, I.V.; Drobot, V.V.

    1985-01-01

    The mechanism of the reaction 3 He+p → p+p+d is studied making use of the ITEP 80-cm liquid-hydrogen bubble chamber exposed to the beam of 5 GeV/c 3 He nuclei. The reaction cross sections is equal to 20.6+-0.3 mb. The phase space regions associated with quasi-free scattering (QFS) and final state interaction (FSI) are selected. Angular, mass and momentum distributions of the reaction products are obtained in the entire kinematically allowed range. The experimental data in the QFS region are compared with theoretical calculations based on the simplest pole diagram approximation. The 3 He and deuteron wave functions (WF) correspond to the realistic Reid potential. The D-wave components of these WF are taken into account. The absolute value of the cross section and shape of the distributions are described as a whole reasonably enough in the frame of the considered model in the kinematical region where FSI may be neglected

  3. Dissipation of flow in superfluid 3He-A

    International Nuclear Information System (INIS)

    Paalanen, M.A.; Osheroff, D.D.

    1980-01-01

    The first direct measurements of the dissipation due to flow are performed and the effects of that flow on the NMR properties of 3 He-A are studied. A temperature-independent critical velocity v/sub c/=0.52 mm/s is observed, above which a pressure difference proportional to v/sub s/-v/sub c/ developes across our flow orifice. simultaneously, the NMR frequency in 3 He-A is lowered by an amount also proportional to v/sub s/-v/sub c/, in contrast to current theoretical predictions

  4. A Pilot Comparative Study of Quantitative Ultrasound, Conventional Ultrasound, and MRI for Predicting Histology-Determined Steatosis Grade in Adult Nonalcoholic Fatty Liver Disease.

    Science.gov (United States)

    Paige, Jeremy S; Bernstein, Gregory S; Heba, Elhamy; Costa, Eduardo A C; Fereirra, Marilia; Wolfson, Tanya; Gamst, Anthony C; Valasek, Mark A; Lin, Grace Y; Han, Aiguo; Erdman, John W; O'Brien, William D; Andre, Michael P; Loomba, Rohit; Sirlin, Claude B

    2017-05-01

    The purpose of this study is to explore the diagnostic performance of two investigational quantitative ultrasound (QUS) parameters, attenuation coefficient and backscatter coefficient, in comparison with conventional ultrasound (CUS) and MRI-estimated proton density fat fraction (PDFF) for predicting histology-confirmed steatosis grade in adults with nonalcoholic fatty liver disease (NAFLD). In this prospectively designed pilot study, 61 adults with histology-confirmed NAFLD were enrolled from September 2012 to February 2014. Subjects underwent QUS, CUS, and MRI examinations within 100 days of clinical-care liver biopsy. QUS parameters (attenuation coefficient and backscatter coefficient) were estimated using a reference phantom technique by two analysts independently. Three-point ordinal CUS scores intended to predict steatosis grade (1, 2, or 3) were generated independently by two radiologists on the basis of QUS features. PDFF was estimated using an advanced chemical shift-based MRI technique. Using histologic examination as the reference standard, ROC analysis was performed. Optimal attenuation coefficient, backscatter coefficient, and PDFF cutoff thresholds were identified, and the accuracy of attenuation coefficient, backscatter coefficient, PDFF, and CUS to predict steatosis grade was determined. Interobserver agreement for attenuation coefficient, backscatter coefficient, and CUS was analyzed. CUS had 51.7% grading accuracy. The raw and cross-validated steatosis grading accuracies were 61.7% and 55.0%, respectively, for attenuation coefficient, 68.3% and 68.3% for backscatter coefficient, and 76.7% and 71.3% for MRI-estimated PDFF. Interobserver agreements were 53.3% for CUS (κ = 0.61), 90.0% for attenuation coefficient (κ = 0.87), and 71.7% for backscatter coefficient (κ = 0.82) (p hepatic steatosis grade in patients with NAFLD.

  5. Genealogical series method. Hyperpolar points screen effect

    International Nuclear Information System (INIS)

    Gorbatov, A.M.

    1991-01-01

    The fundamental values of the genealogical series method -the genealogical integrals (sandwiches) have been investigated. The hyperpolar points screen effect has been found. It allows one to calculate the sandwiches for the Fermion systems with large number of particles and to ascertain the validity of the iterated-potential method as well. For the first time the genealogical-series method has been realized numerically for the central spin-independent potential

  6. Optimizing moderation of He-3 neutron detectors for shielded fission sources

    Energy Technology Data Exchange (ETDEWEB)

    Rees, Lawrence B., E-mail: Lawrence_Rees@byu.edu [Department of Physics and Astronomy, Brigham Young University, Provo, UT 84602 (United States); Czirr, J. Bart, E-mail: czirr@juno.com [Department of Physics and Astronomy, Brigham Young University, Provo, UT 84602 (United States)

    2012-11-01

    The response of a {sup 3}He neutron detector is highly dependent on the amount of moderator incorporated into the detector system. If there is too little moderation, neutrons will not react with the {sup 3}He. If there is too much moderation, neutrons will not reach the {sup 3}He. In applications for portal or border monitors where {sup 3}He detectors are used to interdict illicit importation of plutonium, the fission source is always shielded to some extent. Since the energy distribution of neutrons emitted from the source depends on the amount and type of shielding present, the optimum placement of moderating material around {sup 3}He tubes is a function of shielding. In this paper, we use Monte Carlo techniques to model the response of {sup 3}He tubes placed in polyethylene boxes for moderation. To model the shielded fission neutron source, we use a point {sup 252}Cf source placed in the center of polyethylene spheres of varying radius. Detector efficiency as a function of box geometry and shielding is explored. We find that increasing the amount of moderator behind and to the sides of the detector generally improves the detector response, but that incremental benefits are minimal if the thickness of the polyethylene moderator is greater than about 5-7 cm. The thickness of the moderator in front of the {sup 3}He tubes, however, is very important. For bare sources, about 4-5 cm of moderator is optimum, but as the shielding increases, the optimum thickness of this moderator decreases to 0.5-1 cm. Similar conclusions can be applied to polyethylene boxes employing two {sup 3}He tubes. Two-tube boxes with front moderators of non-uniform thickness may be useful for detecting neutrons over a wide energy range.

  7. Combined 3 Tesla MRI Biomarkers Improve the Differentiation between Benign vs Malignant Single Ring Enhancing Brain Masses.

    Directory of Open Access Journals (Sweden)

    Simone Salice

    Full Text Available To evaluate whether the combination of imaging biomarkers obtained by means of different 3 Tesla (3T Magnetic Resonance Imaging (MRI advanced techniques can improve the diagnostic accuracy in the differentiation between benign and malignant single ring-enhancing brain masses.14 patients presenting at conventional 3T MRI single brain mass with similar appearance as regard ring enhancement, presence of peri-lesional edema and absence of hemorrhage signs were included in the study. All lesions were histologically proven: 5 pyogenic abscesses, 6 glioblastomas, and 3 metastases. MRI was performed at 3 Tesla and included Diffusion Weighted Imaging (DWI, Dynamic Susceptibility Contrast -Perfusion Weighted Imaging (DSC-PWI, Magnetic Resonance Spectroscopy (MRS, and Diffusion Tensor Imaging (DTI. Imaging biomarkers derived by those advanced techniques [Cerebral Blood Flow (CBF, relative Cerebral Blood Volume (rCBV, relative Main Transit Time (rMTT, Choline (Cho, Creatine (Cr, Succinate, N-Acetyl Aspartate (NAA, Lactate (Lac, Lipids, relative Apparent Diffusion Coefficient (rADC, and Fractional Anisotropy (FA] were detected by two experienced neuroradiologists in joint session in 4 areas: Internal Cavity (IC, Ring Enhancement (RE, Peri-Lesional edema (PL, and Contralateral Normal Appearing White Matter (CNAWM. Significant differences between benign (n = 5 and malignant (n = 9 ring enhancing lesions were tested with Mann-Withney U test. The diagnostic accuracy of MRI biomarkers taken alone and MRI biomarkers ratios were tested with Receiver Operating Characteristic (ROC analysis with an Area Under the Curve (AUC ≥ 0.9 indicating a very good diagnostic accuracy of the variable.Five MRI biomarker ratios achieved excellent accuracy: IC-rADC/PL-NAA (AUC = 1, IC-rADC/IC-FA (AUC = 0.978, RE-rCBV/RE-FA (AUC = 0.933, IC-rADC/RE-FA (AUC = 0.911, and IC-rADC/PL-FA (AUC = 0.911. Only IC-rADC achieved a very good diagnostic accuracy (AUC = 0.909 among MRI biomarkers

  8. Progress on pebble bed experimental activity for the HE-FUS3 mock-ups

    International Nuclear Information System (INIS)

    Dell'Orco, G.; Sansone, L.; Simoncini, M.; Zito, D.

    2002-01-01

    The EU Long Term for DEMO Programme foresees the qualification of the reference design of the helium cooled pebble bed (HCPB) - test blanket module (TBM) to be tested in ITER Reactor. In this frame, FZK and ENEA have launched many experimental activities for the evaluation of the interactions between the Tritium breeder and neutron multiplier pebble beds and the steel containment walls. Main aim of these activities is the measuring the pebble bed effective thermal conductivity, the wall heat transfer coefficient as well as their dependency from the mechanical constraints. The paper presents the progress of the testing activity and results of the tests on two mock-up, called Tazza and Helichetta, carried out on the HE-FUS3 facility at ENEA Brasimone. (orig.)

  9. Proton magnetic resonance with parahydrogen induced polarization. Imaging strategies and continuous generation

    International Nuclear Information System (INIS)

    Dechent, Jan Falk Frederik

    2012-01-01

    A major challenge in imaging is the detection of small amounts of molecules of interest. In the case of magnetic resonance imaging (MRI) their signals are typically concealed by the large background signal of e.g. the tissue of the body. This problem can be tackled by hyperpolarization which increases the NMR signals up to several orders of magnitude. However, this strategy is limited for 1 H, the most widely used nucleus in NMR and MRI, because the enormous number of protons in the body screen the small amount of hyperpolarized ones. Here, I describe a method giving rise to high 1 H MRI contrast for hyperpolarized molecules against a large background signal. The contrast is based on the J-coupling induced rephasing of the NMR signal of molecules hyperpolarized via parahydrogen induce polarization (PHIP) and it can easily be implemented in common pulse sequences. Hyperpolarization methods typically require expensive technical equipment (e.g. lasers or microwaves) and most techniques work only in batch mode, thus the limited lifetime of the hyperpolarization is limiting its applications. Therefore, the second part of my thesis deals with the simple and efficient generation of an hyperpolarization. These two achievements open up alternative opportunities to use the standard MRI nucleus 1 H for e.g. metabolic imaging in the future.

  10. Proton magnetic resonance with parahydrogen induced polarization. Imaging strategies and continuous generation

    Energy Technology Data Exchange (ETDEWEB)

    Dechent, Jan Falk Frederik

    2012-12-17

    A major challenge in imaging is the detection of small amounts of molecules of interest. In the case of magnetic resonance imaging (MRI) their signals are typically concealed by the large background signal of e.g. the tissue of the body. This problem can be tackled by hyperpolarization which increases the NMR signals up to several orders of magnitude. However, this strategy is limited for {sup 1}H, the most widely used nucleus in NMR and MRI, because the enormous number of protons in the body screen the small amount of hyperpolarized ones. Here, I describe a method giving rise to high {sup 1}H MRI contrast for hyperpolarized molecules against a large background signal. The contrast is based on the J-coupling induced rephasing of the NMR signal of molecules hyperpolarized via parahydrogen induce polarization (PHIP) and it can easily be implemented in common pulse sequences. Hyperpolarization methods typically require expensive technical equipment (e.g. lasers or microwaves) and most techniques work only in batch mode, thus the limited lifetime of the hyperpolarization is limiting its applications. Therefore, the second part of my thesis deals with the simple and efficient generation of an hyperpolarization. These two achievements open up alternative opportunities to use the standard MRI nucleus {sup 1}H for e.g. metabolic imaging in the future.

  11. Results on Double-polarization Asymmetries in Quasielastic Scattering from Polarized 3He

    Directory of Open Access Journals (Sweden)

    Sulkosky Vincent A.

    2016-01-01

    Full Text Available The 3He nucleus has become extremely important in the investigation of the neutron’s spin structure. When polarized, 3He acts as an effective polarized neutron target and hence facilitates our understanding of the neutron’s internal structure. However, to be used in this manner, our understanding of the internal structure of 3He is of extreme importance. As the precision of experiments has improved, the extraction of polarized neutron information from 3He leads to an ever larger share of the systematic uncertainty for these experiments. In these proceedings, I present a precise measurement of beam-target asymmetries in the He→3(e→ ,e′d${}^3\\overrightarrow {He} (\\vec e,e'd$ and He→3(e→,e′p${}^3\\overrightarrow {He} (\\vec e,e'p$ reactions. The former process is a uniquely sensitive probe of hadron dynamics in 3He and the structure of the underlying electromagnetic currents. The measurements have been performed around the quasi-elastic peak at Q2 = 0.25 (GeV/c2 and 0.35 (GeV/c2 for recoil momenta up to 270 MeV/c. The experimental apparatus, analysis and results were presented together with a comparison to state-of-the art Faddeev calculations.

  12. Differentiation of benign and malignant lesions of the tongue by using diffusion-weighted MRI at 3.0 T.

    Science.gov (United States)

    Li, S; Cheng, J; Zhang, Y; Zhang, Z

    2015-01-01

    Diffusion-weighted MRI (DWI) has been introduced in head and neck lesions and adds important information to the findings obtained through conventional MRI. The purpose of this study was to assess the role of DWI in differentiating benign and malignant lesions of the tongue at 3.0-T field strength imaging. 78 patients with 78 lingual lesions underwent conventional MRI and DWI with b-values of 0 and 1000 s mm(-2) before therapy. The apparent diffusion coefficient (ADC) maps were reconstructed, and the ADC values of the lingual lesions were calculated and compared between benign and malignant lesions of the tongue. The mean ADC values of the malignant tumours, benign solid lesions and cystic lesions were (1.08±0.16)×10(-3), (1.68±0.33)×10(-3) and (2.21±0.35)×10(-3) mm2 s(-1), respectively. The mean ADC values of malignant tumours were significantly lower (pbenign and malignant lesions are significantly different at 3.0-T imaging. DWI can be applied as a complementary tool in the differentiation of benign and malignant lesions of the tongue.

  13. 3He release characteristics of metal tritides and scandium--tritium solid solutions

    International Nuclear Information System (INIS)

    Perkins, W.G.; Kass, W.J.; Beavis, L.C.

    1976-01-01

    Tritides of such metals as Sc, Ti, and Er are useful materials for determining the effects of He accumulation in metallic solids, for example, CTR first wall materials. Such effects include lattice strain and gross deformation which are related to 3 He retention and ultimate release. Long term gas release studies have indicated that, during the early life of a metal ditritide, a large fraction of the 3 He is retained in the solid. At more advanced ages, the 3 He release rate becomes comparable to the generation rate. Statistical analysis of the data indicates that the acceleration in 3 He release rate depends on accumulated 3 He concentration rather than strictly on age. 3 He outgassing results are presented for thin films of ScT 2 , TiT 2 , and ErT 2 , and the critical 3 He concentrations are discussed in terms of a percolation model. Phase transformations which occur on tritide formation cast some doubt on the validity of extrapolating results obtained for metal tritides to predictions regarding the accumulation of helium in metals. Sc is unique among the early transition and rare-earth metals in that the metal exhibits a very high room temperature T solubility (T/Sc = 0.4) with no phase transformation. Indeed, even the lattice parameters of the hcp Sc lattice are only minimally changed by T solution. Single crystal ScT/sub 0.3/ samples in two crystallographic orientations were obtained. Using a very sensitive technique, 3 He emission was measured from both these samples, as well as from fine-grained thin film Sc--T solid solution samples (ScT/sub 0.3-0.4/). The fine-grained film samples release 3 He at 2-3 percent of the generation rate, while the emission rate from the single-crystal samples is approximately 0.05 percent of the generation rate, indicating a strong grain size effect

  14. Validity and reliability of 3D US for the detection of erosions in patients with rheumatoid arthritis using MRI as the gold standard

    DEFF Research Database (Denmark)

    Ellegaard, K; Bliddal, H; Møller Døhn, U

    2014-01-01

    PURPOSE: To test the reliability and validity of a 3D US erosion score in RA using MRI as the gold standard. MATERIALS AND METHODS: RA patients were examined with 3D US and 3 T MRI over the 2nd and 3rd metacarpophalangeal joints. 3D blocks were evaluated by two investigators. The erosions were...... estimated according to a semi-quantitative score (SQS) (0 - 3) and a quantitative score (QS) (mm²). MRI was evaluated according to the RAMRIS score. For the estimation of reliability, intra-class correlation coefficients (ICC) were used. Validity was tested using Spearman's rho (rs). The sensitivity...... and specificity were also calculated. RESULTS: 28 patients with RA were included. The ICC for the inter-observer reliability in the QS was 0.41 and 0.13 for the metacarpal bone and phalangeal bone, respectively, and 0.86 and 0.16, respectively, in the SQS.  The ICC for the intra-observer reliability in the QS...

  15. Hyperfine Structure Measurements of Antiprotonic $^3$He using Microwave Spectroscopy

    CERN Document Server

    Friedreich, Susanne

    The goal of this project was to measure the hyperfine structure of $\\overline{\\text{p}}^3$He$^+$ using the technique of laser-microwave-laser spectroscopy. Antiprotonic helium ($\\overline{\\text{p}}$He$^+$) is a neutral exotic atom, consisting of a helium nucleus, an electron and an antiproton. The interactions of the angular momenta of its constituents cause a hyperfine splitting ({HFS}) within the energy states of this new atom. The 3\\% of formed antiprotonic helium atoms which remain in a metastable, radiative decay-dominated state have a lifetime of about 1-3~$\\mu$s. This time window is used to do spectroscopic studies. The hyperfine structure of $\\overline{\\text{p}}^4$He$^+$ was already extensively investigated before. From these measurements the spin magnetic moment of the antiproton can be determined. A comparison of the result to the proton magnetic moment provides a test of {CPT} invariance. Due to its higher complexity the new exotic three-body system of $\\overline{\\text{p}}^3$He$^+$ is a cross-check...

  16. The ground state energy of 3He droplet in the LOCV framework

    International Nuclear Information System (INIS)

    Modarres, M.; Motahari, S.; Rajabi, A.

    2012-01-01

    The (extended) lowest order constrained variational method was used to calculate the ground state energy of liquid helium 3 ( 3 He) droplets at zero temperature. Different types of density distribution profiles, such as the Gaussian, the Quasi-Gaussian and the Woods-Saxon were used. It was shown that at least, on average, near 20 3 He atoms are needed to get the bound state for 3 He liquid droplet. Depending on the choice of the density profiles and the atomic radius of 3 He, the above estimate can increase to 300. Our calculated ground state energy and the number of atoms in liquid 3 He droplet were compared with those of Variational Monte Carlo method, Diffusion Monte Carlo method and Density Functional Theory, for which a reasonable agreement was found.

  17. The 3He spectral function in light-front dynamics

    Directory of Open Access Journals (Sweden)

    Rinaldi Matteo

    2016-01-01

    Full Text Available A distorted spin-dependent spectral function for 3He is considered for the extraction of the transverse-momentum dependent parton distributions in the neutron from semi-inclusive deep inelastic electron scattering off polarized 3He at finite momentum transfers, where final state interactions are taken into account. The generalization of the analysis to a Poincaré covariant framework within the light-front dynamics is outlined.

  18. Pionic annihilation of antiprotons stopped on sup 3 He

    Energy Technology Data Exchange (ETDEWEB)

    Bendiscioli, G.; Filippini, V.; Rotondi, A.; Salvini, P.; Venaglioni, A. (Pavia Univ. (Italy). Dipt. di Fisica Nucleare e Teorica Istituto Nazionale di Fisica Nucleare, Pavia (Italy)); Bossolasco, S.; Bussa, M.P.; Busso, L.; Fava, L.; Ferrero, L.; Maggiora, A.; Panzieri, D.; Piragino, G.; Piragino, R.; Tosello, F. (Turin Univ. (Italy). Ist. di Fisica Generale Istituto Nazionale di Fisica Nucleare, Turin (Italy)); Batusov, Yu.A.; Falomkin, I.V.; Pontecorvo, G.B.; Rozhdestvensky, A.M.; Sapozhnikov, M.G.; Tretyak, V.I. (Joint Inst. for Nuclear Research, Dubna (USSR)); Guaraldo, C. (Istituto Nazionale di Fisica Nucleare, Frascati (Italy). Lab. Nazionale di Frascati); Lodi Rizzini, E. (Brescia Univ. (Italy). Dipt. di Automazione Industriale Istituto Nazionale di Fisica Nucleare, Turin (Italy)); Haatuft, A.; Halsteinslid, A.; Myklebost, K.; Olsen, J.M. (Bergen Univ. (Norway). Dept. of Physics); Breivik, F.O.; Jacobsen, T.; Soerensen, S.O. (Oslo Univ. (Norway). Physics Dept.); Balestra

    1990-11-26

    The pionic annihilation of antiprotons stopped on {sup 3}He nuclei in a self-shunted streamer chamber exposed to the antiproton beam of LEAR is studied. The data concern charged-particle multiplicity distributions, branching ratios for different final states, the probability of final-state interaction, {pi}{sup -}, {pi}{sup +}, p and d momentum spectra, like and unlike pion angular correlations, {pi} and other charged-particle angular correlations. The comparison of the {sup 3}He data with those obtained on {sup 1}H, {sup 2}H and {sup 4}He does not reveal relevant effects due to the increase of the nucleon number; the small differences can be seen as due to a weak final-state interaction. (orig.).

  19. Theoretical charge-exchange total cross sections for B+3 + He and C+4 + He collisions

    International Nuclear Information System (INIS)

    Shipsey, E.J.; Browne, J.C.; Olson, R.E.

    1977-01-01

    Charge-exchange total cross sections for the B +3 + He and C +4 + He systems have been calculated in the velocity range v = (1--10) x 10 7 cm/sec. Ab initio potential-energy curves and coupling-matrix elements were computed and employed in the impact-parameter classical-coupled equations that describe the collision to obtain the cross sections. For the B +3 + He system, our calculations are in excellent agreement with experimental results with the finding that the single-electron-transfer cross section rises rapidly to a maximum of 1.45 x 10 -15 cm 2 at v = 5.5 x 10 7 cm/sec. For the C +4 + He system, however, we find that the double-electron-transfer process is more important than the single-electron-transfer process. For example, at v = 5 x 10 7 cm/sec, the double-electron-transfer cross section is found to be 0.6 x 10 -16 cm 2 vs 5.5 x 10 -17 for the single-electron transfer. This is in disagreement with an experiment of Crandall which gave the single-charge-transfer process as dominant. However, the more recent experiment reported by Crandall, Olson, Browne, and Shipsey verifies the double charge transfer as the dominant process for low energies

  20. On some properties of SU(3 fusion coefficients

    Directory of Open Access Journals (Sweden)

    Robert Coquereaux

    2016-11-01

    Full Text Available Three aspects of the SU(3 fusion coefficients are revisited: the generating polynomials of fusion coefficients are written explicitly; some curious identities generalizing the classical Freudenthal–de Vries formula are derived; and the properties of the fusion coefficients under conjugation of one of the factors, previously analyzed in the classical case, are extended to the affine algebra suˆ(3 at finite level.

  1. Production of e(+)e(-) pairs in proton-deuteron capture to He-3

    NARCIS (Netherlands)

    Korchin, AY; Van Neck, D; Waroquier, M; Scholten, O; Dieperink, AEL

    1998-01-01

    The process p + d He-3 + gamma * at intermediate energies is described using a covariant and gauge-invariant model, and a realistic pd(3)He vertex, Both photodisintegration of He-3 and proton-deuteron capture with production of e(+)e(-) pairs are studied, and results for cross sections and response

  2. Towards the observation of the magnetic structure of solid 3He

    International Nuclear Information System (INIS)

    Rufin, D.

    1982-03-01

    Experiments involving neutron scattering by 3 He for which thermalization problems have been solved, along with the development of novel measurement techniques (density, magnetization, temperature) by polarized neutron transmission, crystallization experiments with 3 He and 4 He: a single crystal of helium have been obtained within a sintered metal in which the pore size is less than a micron are presented [fr

  3. Preconceptual engineering design for the APT 3He Target/Blanket concept

    International Nuclear Information System (INIS)

    Mensink, D.L.

    1994-01-01

    A preconceptual engineering design has been developed for the 3 He Target/Blanket (T/B) System for the Accelerator Production of Tritium Project. This concept uses an array of pressure tubes containing tungsten rods for the neutron spallation source and 3 He gas contained in a metal tank and blanket tubes as the tritium production material. The engineering design is based on a physics model optimized for efficient tritium production. Principle engineering consideration were: provisions for cooling all materials including the 3 He gas; containment of the gas and radionuclides; remote handling; material compatibility; minimization of 3 He, D 2 O, and activated waste; modularity; and manufacturability. The design provides a basis for estimating the cost to implement the system

  4. Phase transition of two-dimensional 3He from a dilute to a dense phase

    International Nuclear Information System (INIS)

    Bhattacharyya, B.K.; Gasparini, F.M.

    1985-01-01

    We have measured the heat capacity of 3 He in films of 4 He as thin as 10 A formed on a Nuclepore filter substrate. At low temperatures, where the 3 He is in the lowest state as far as motion perpendicular to the film surface, we find that the 3 He undergoes a transition from a dilute phase to a dense phase. We have observed this transition for films of 4 He of 12.3- and 10-A thickness and for coverages of 3 He below about 0.2 atomic layers. For thicker 4 He films, and higher 3 He coverages, the 3 He remains homogeneously spread out over the surface of the 4 He. The striking characteristic of the transition is the sudden onset of linear temperature dependence with a slope which is proportional to the amount of 3 He in the calorimeter. This is consistent with the formation of islands of a dense two-dimensional phase which grows in extent proportionately to the amount of 3 He. Two puzzling aspects of our results are the lack of a significant heat-capacity jump at the transition and, based on a linear extrapolation of the data to zero temperature, a substantial amount of missing entropy

  5. Study of the (3He,t) reaction on 48Ca at 82 MeV

    International Nuclear Information System (INIS)

    Tanabe, T.; Yasue, M.; Sato, K.; Soga, F.; Igarashi, M.; Ogino, K.; Kadota, Y.; Saito, Y.; Shimokoshi, F.

    1978-01-01

    The reactions ( 3 He,t), ( 3 He, 3 He), ( 3 He,α) and ( 3 He,d) on 48 Ca have been studied at an incident energy of 82 MeV. The obtained angular distributions for the ( 3 He,t) reaction have been analyzed in terms of second-order DWBA theory, using a zero-range approximation. The relative ratio of the cross sections for the excitation of the fsub(7/2)f -1 sub(7/2) multiplets of 48 Sc could not be explained consistently by the one-step charge-exchange process only. However, the ratio was reproduced in order of magnitude by second-order DWBA calculations including the effect of two-step processes, such as ( 3 He-α-t) and ( 3 He-d-t) channels. The effects of the d- and α-channels on the elastic scattering of 3 He from 48 Ca were also examined in the framework of second-order full finite-range DWBA. (Auth.)

  6. 3He/4He ratio, noble gas abundance and K-Ar dating of diamonds - an attempt to search for the records of early terrestrial history

    International Nuclear Information System (INIS)

    Ozima, M.; Zashu, S.; Nitoh, O.

    1983-01-01

    The 3 He/ 4 He ratios measured in 27 Southern Africa diamond stones, four from Premier Mine and the rest of unidentified origin, range from 4.2 x 10 -8 to 3.2 x 10 -4 , with three stones above 1 x 10 -4 . We conclude that the initial helium isotopic ratio ( 3 He/ 4 He) 0 in the earth was significantly higher than that of the planetary helium-A ( 3 He/ 4 He = 1.42 x 10 -4 ), but close to the solar helium ( 3 He/ 4 He = approx. 4 x 10 -4 ). The apparent K-Ar ages for the twelve diamonds of unidentified origin show enormously old age, indicating excess argon-40. 3 He/ 4 He evolution in diamonds suggests that the diamonds with the high 3 He/ 4 He ratio (> 2 x 10 -4 ) may be as old as the earth. Noble gas elemental abundance in the diamonds relative to the air noble gas abundance shows monotonic decrease with a decreasing mass number. This paper discusses the implications of these observations on the early solar system and the origin of diamonds. (author)

  7. A catalyzing phantom for reproducible dynamic conversion of hyperpolarized [1-¹³C]-pyruvate.

    Science.gov (United States)

    Walker, Christopher M; Lee, Jaehyuk; Ramirez, Marc S; Schellingerhout, Dawid; Millward, Steven; Bankson, James A

    2013-01-01

    In vivo real time spectroscopic imaging of hyperpolarized ¹³C labeled metabolites shows substantial promise for the assessment of physiological processes that were previously inaccessible. However, reliable and reproducible methods of measurement are necessary to maximize the effectiveness of imaging biomarkers that may one day guide personalized care for diseases such as cancer. Animal models of human disease serve as poor reference standards due to the complexity, heterogeneity, and transient nature of advancing disease. In this study, we describe the reproducible conversion of hyperpolarized [1-¹³C]-pyruvate to [1-¹³C]-lactate using a novel synthetic enzyme phantom system. The rate of reaction can be controlled and tuned to mimic normal or pathologic conditions of varying degree. Variations observed in the use of this phantom compare favorably against within-group variations observed in recent animal studies. This novel phantom system provides crucial capabilities as a reference standard for the optimization, comparison, and certification of quantitative imaging strategies for hyperpolarized tracers.

  8. A catalyzing phantom for reproducible dynamic conversion of hyperpolarized [1-¹³C]-pyruvate.

    Directory of Open Access Journals (Sweden)

    Christopher M Walker

    Full Text Available In vivo real time spectroscopic imaging of hyperpolarized ¹³C labeled metabolites shows substantial promise for the assessment of physiological processes that were previously inaccessible. However, reliable and reproducible methods of measurement are necessary to maximize the effectiveness of imaging biomarkers that may one day guide personalized care for diseases such as cancer. Animal models of human disease serve as poor reference standards due to the complexity, heterogeneity, and transient nature of advancing disease. In this study, we describe the reproducible conversion of hyperpolarized [1-¹³C]-pyruvate to [1-¹³C]-lactate using a novel synthetic enzyme phantom system. The rate of reaction can be controlled and tuned to mimic normal or pathologic conditions of varying degree. Variations observed in the use of this phantom compare favorably against within-group variations observed in recent animal studies. This novel phantom system provides crucial capabilities as a reference standard for the optimization, comparison, and certification of quantitative imaging strategies for hyperpolarized tracers.

  9. A new type of liquid-3He target system using small mechanical refrigerators

    International Nuclear Information System (INIS)

    Kato, S.; Kobayashi, K.; Maruyama, K.; Okuno, H.; Konno, O.; Suda, T.; Maki, T.; Asami, H.; Koizumi, T.

    1991-04-01

    A new type of liquid- 3 He target has been developed for photoabsorption experiments at intermediate energies. Using the cooling power of liquid 4 He at reduced vapour pressure, 3 He gas is liquefied into a cylindrical target cell of 180 ml and is maintained at 2.0 K during the experiment. Evaporated 4 He gas is evacuated by a rotary pump and returned into the 4 He bath in the cryostat, where two small mechanical refrigerators with cooling capacities of 3 W at 4.3 K and 10 W at 20 K are operated for the purpose of 4 He recondensation. A maintenance-free operation of more than 1,000 hours has become possible by adopting the 4 He circulation system. (author)

  10. Recent Spin Pump Experiments on Superfluid 3He-A1

    Science.gov (United States)

    Yamaguchi, A.; Kamada, N.; Motoyama, G.; Sumiyama, A.; Aoki, Y.; Okuda, Y.; Kubota, M.; Kojima, H.

    2013-05-01

    The superfluid 3He A1 phase, containing a spin-polarized condensate allows us to explore the dynamics of superfluid spin current. In the mechano-spin effect (MSE), a mechanically applied pressure gradient and a superleak-spin filter enable one to directly boost spin polarization of 3He in a small chamber. We are developing new apparatus for achieving greater enhancement of spin density. A development of a new-type 3He-hydraulic actuator has been already reported. We present here the construction of new-type of superleak-spin-filter made of packed powder aluminum oxide (referred as PAP-SL). The PAP-SL is popular in the study of superfluid 4He, but has not been established for that of the superfluid 3He. The attempt to construct the PAP-SL for the spin pump experiment was made by using aluminum oxide powder with nominal 1 μm powder diameter and with packing fraction of 40 %. Before executing the experiment, the nuclear demagnetization cryostat of ISSP, Univ. Tokyo which has been used for this experimental activity, was heavily damaged by the 2011 Great East Japan (Higashi Nihon) Earthquake. The repair work and earthquake damage protection strengthening has just been accomplished.

  11. Designing an Epithermal Neutron Beam for Boron Neutron Capture Therapy for the Fusion Reactions 2H(d,n)3He and 3H(d,n)4He1

    International Nuclear Information System (INIS)

    Verbeke, J.M.; Costes, S.V.; Bleuel, D.; Vujic, J.; Leung, K.N.

    1998-01-01

    A beam shaping assembly has been designed to moderate high energy neutrons from the fusion reactions 2 H(d,N) 3 He and 3 H(d,n) 4 He for use fin boron neutron capture therapy. The low neutron yield of the 2 H(d,n) 3 He reaction led to unacceptably long treatment times. However, a 160 mA deuteron beam of energy 400 keV led to a treatment time of 120 minutes with the reaction 3 H(d,n) 4 He. Equivalent doses of 9.6 Gy-Eq and 21.9 Gy-Eq to the skin and to a 8 cm deep tumor respectively have been computed

  12. Dimension effect in impuriton gas of 3He -4He superfluid mixture

    International Nuclear Information System (INIS)

    Adamenko, I.N.; Bortnik, L.N.; Chervanev, A.I.

    1999-01-01

    The flow of quasiparticle gas forced by the gradients of thermodynamical values in the volume filled with a powder is considered. The exact solution of the kinetic equation is obtained. It is expressed in terms of matrix elements of the collision integral and partial scattering cross-sections of quasiparticles at the powder. The condition describing the steady non-equilibrium state of the quasiparticles gas in the volume filled with a porous material is obtained. The results obtained are valid for arbitrary relations of frequencies of quasiparticle-quasiparticle and quasiparticle-powder collisions. The transitions from the Knudsen regime of quasiparticle gas flow to the hydrodynamic one is investigated. The Knudsen effect in degenerated quantum gas is studied. The steady non-equilibrium state of 3 He- 4 He superfluid mixture impuriton gas is studied in confined geometry

  13. Investigating tumor perfusion and metabolism using multiple hyperpolarized 13C compounds: HP001, pyruvate and urea

    DEFF Research Database (Denmark)

    von Morze, Cornelius; Larson, Peder E.Z.; Hu, Simon

    2012-01-01

    The metabolically inactive hyperpolarized agents HP001 (bis-1,1-(hydroxymethyl)-[1-13C]cyclopropane-d8) and urea enable a new type of perfusion magnetic resonance imaging based on a direct signal source that is background-free. The addition of perfusion information to metabolic information obtained...... (T1=95 s ex vivo, 32 s in vivo at 3 T) using a pulse sequence with balanced steady-state free precession and ramped flip angle over time for efficient utilization of the hyperpolarized magnetization and three-dimensional echo-planar spectroscopic imaging of urea copolarized with [1-13C...... of separate dynamic HP001 imaging and copolarized pyruvate/urea imaging were compared. A strong and significant correlation (R=0.73, P=.02) detected between the urea and HP001 data confirmed the value of copolarizing urea with pyruvate for simultaneous assessment of perfusion and metabolism....

  14. Fluconazole treatment hyperpolarizes the plasma membrane of Candida cells

    Czech Academy of Sciences Publication Activity Database

    Elicharová, Hana; Sychrová, Hana

    2013-01-01

    Roč. 51, č. 8 (2013), s. 785-798 ISSN 1369-3786 R&D Projects: GA ČR GAP302/12/1151 Institutional research plan: CEZ:AV0Z50110509 Institutional support: RVO:67985823 Keywords : drug resistance * fluconazol * yeast * hyperpolarization Subject RIV: EE - Microbiology, Virology Impact factor: 2.261, year: 2013

  15. Development of data acquisition system for CSNS 3He detector

    International Nuclear Information System (INIS)

    Zhao Dongxu; Zhang Hongyu

    2012-01-01

    This paper introduces the research and development of data acquisition system of CSNS 3 He detector prototype. This system provides high performance data acquisition capability of CSNS 3 He detector, as well as several performance tests of electronics prototype. This data acquisition system establishes foundation for the later data acquisition development. (authors)

  16. 3D printing from MRI Data: Harnessing strengths and minimizing weaknesses.

    Science.gov (United States)

    Ripley, Beth; Levin, Dmitry; Kelil, Tatiana; Hermsen, Joshua L; Kim, Sooah; Maki, Jeffrey H; Wilson, Gregory J

    2017-03-01

    3D printing facilitates the creation of accurate physical models of patient-specific anatomy from medical imaging datasets. While the majority of models to date are created from computed tomography (CT) data, there is increasing interest in creating models from other datasets, such as ultrasound and magnetic resonance imaging (MRI). MRI, in particular, holds great potential for 3D printing, given its excellent tissue characterization and lack of ionizing radiation. There are, however, challenges to 3D printing from MRI data as well. Here we review the basics of 3D printing, explore the current strengths and weaknesses of printing from MRI data as they pertain to model accuracy, and discuss considerations in the design of MRI sequences for 3D printing. Finally, we explore the future of 3D printing and MRI, including creative applications and new materials. 5 J. Magn. Reson. Imaging 2017;45:635-645. © 2016 International Society for Magnetic Resonance in Medicine.

  17. Characterization of Chemical Exchange Using Relaxation Dispersion of Hyperpolarized Nuclear Spins.

    Science.gov (United States)

    Liu, Mengxiao; Kim, Yaewon; Hilty, Christian

    2017-09-05

    Chemical exchange phenomena are ubiquitous in macromolecules, which undergo conformational change or ligand complexation. NMR relaxation dispersion (RD) spectroscopy based on a Carr-Purcell-Meiboom-Gill pulse sequence is widely applied to identify the exchange and measure the lifetime of intermediate states on the millisecond time scale. Advances in hyperpolarization methods improve the applicability of NMR spectroscopy when rapid acquisitions or low concentrations are required, through an increase in signal strength by several orders of magnitude. Here, we demonstrate the measurement of chemical exchange from a single aliquot of a ligand hyperpolarized by dissolution dynamic nuclear polarization (D-DNP). Transverse relaxation rates are measured simultaneously at different pulsing delays by dual-channel 19 F NMR spectroscopy. This two-point measurement is shown to allow the determination of the exchange term in the relaxation rate expression. For the ligand 4-(trifluoromethyl)benzene-1-carboximidamide binding to the protein trypsin, the exchange term is found to be equal within error limits in neutral and acidic environments from D-DNP NMR spectroscopy, corresponding to a pre-equilibrium of trypsin deprotonation. This finding illustrates the capability for determination of binding mechanisms using D-DNP RD. Taking advantage of hyperpolarization, the ligand concentration in the exchange measurements can reach on the order of tens of μM and protein concentration can be below 1 μM, i.e., conditions typically accessible in drug discovery.

  18. 3He release characteristics of metal tritides and scandium--tritium solid solutions

    International Nuclear Information System (INIS)

    Perkins, W.G.; Kass, W.J.; Beavis, L.C.

    1975-01-01

    Tritides of such metals as scandium, titanium, and erbium are useful materials for determining the effects of helium accumulation in metallic solids, for example, CTR first wall materials. Such effects include lattice strain and gross deformation, as reported elsewhere, which are related to 3 He retention and ultimate release. Long term gas release studies have indicated that, during the early life of a metal ditritide, a large fraction of the 3 He is retained in the solid. At more advanced ages (2 to 4 years, depending on the parent metal), the 3 He release rate becomes comparable to the generation rate. Statistical analysis of the data indicates that the acceleration in 3 He release rate depends on accumulated 3 He concentration rather than strictly on age. 3 He outgassing results are presented for thin films of ScT 2 , TiT 2 , and ErT 2 , and the critical 3 He concentrations are discussed in terms of a percolation model. Phase transformations which occur on tritide formation cast some doubt on the validity of extrapolating results obtained for metal tritides to predictions regarding the accumulation of helium in metals. Scandium is unique among the early transition and rare-earth metals in that the metal exhibits a very high room temperature tritium solubility (T/Sc = 0.4) with no phase transformation. Indeed, even the lattice parameters of the hcp scandium lattice are only minimally changed by tritium solution, and we have succeeded in obtaining single crystal ScT 0 . 3 samples in two crystallographic orientations. Using a very sensitive technique, we have measured 3 He emission from both these samples, as well as from fine-grained thin film scandium-tritium solid solution samples (ScT 0 . 3 - 0 . 4 ). The fine-grained film samples release 3 He at 2 to 3 percent of the generation rate, while the emission rate from the single-crystal samples is approximately 0.05 percent of the generation rate, indicating a strong grain size effect

  19. Feasibility study on 3D image reconstruction from 2D orthogonal cine-MRI for MRI-guided radiotherapy.

    Science.gov (United States)

    Paganelli, Chiara; Lee, Danny; Kipritidis, John; Whelan, Brendan; Greer, Peter B; Baroni, Guido; Riboldi, Marco; Keall, Paul

    2018-02-11

    In-room MRI is a promising image guidance strategy in external beam radiotherapy to acquire volumetric information for moving targets. However, limitations in spatio-temporal resolution led several authors to use 2D orthogonal images for guidance. The aim of this work is to present a method to concurrently compensate for non-rigid tumour motion and provide an approach for 3D reconstruction from 2D orthogonal cine-MRI slices for MRI-guided treatments. Free-breathing sagittal/coronal interleaved 2D cine-MRI were acquired in addition to a pre-treatment 3D volume in two patients. We performed deformable image registration (DIR) between cine-MRI slices and corresponding slices in the pre-treatment 3D volume. Based on an extrapolation of the interleaved 2D motion fields, the 3D motion field was estimated and used to warp the pre-treatment volume. Due to the lack of a ground truth for patients, the method was validated on a digital 4D lung phantom. On the phantom, the 3D reconstruction method was able to compensate for tumour motion and compared favourably to the results of previously adopted strategies. The difference in the 3D motion fields between the phantom and the extrapolated motion was 0.4 ± 0.3 mm for tumour and 0.8 ± 1.5 mm for whole anatomy, demonstrating feasibility of performing a 3D volumetric reconstruction directly from 2D orthogonal cine-MRI slices. Application of the method to patient data confirmed the feasibility of utilizing this method in real world scenarios. Preliminary results on phantom and patient cases confirm the feasibility of the proposed approach in an MRI-guided scenario, especially for non-rigid tumour motion compensation. © 2018 The Royal Australian and New Zealand College of Radiologists.

  20. Positive ion mobilities in normal liquid 3He at ultralow temperatures

    International Nuclear Information System (INIS)

    Alexander, P.W.

    1978-11-01

    The mobility has been measured of positive ions in liquid 3 he in the range 2.5 mK 3 sub(m)/sup(V) 5 sub(m)/sup(V). The effects of 500 p.p.m. 4 He in the 3 He were investigated. It was found that, at low temperatures, several stable ion species could be produced for 3 He pressures of 23 bar and above and, between 25 mK and 60 mK, time dependent conversion from one species of ion to another was observed at all pressures. The creation mechanism, mobility and stability of multiple positive ions were studied. Possible explanations of the phenomena are discussed. The measured drift field dependence of mobility is used to test the quasiparticle scattering model assumed for the liquid. (U.K.)

  1. The SLAC high-density gaseous polarized 3He target

    International Nuclear Information System (INIS)

    Johnson, J.R.; Chupp, T.E.; Smith, T.B.; Cates, G.D.; Driehuys, B.; Middleton, H.; Newbury, N.R.; Hughes, E.W.; Meyer, W.

    1995-01-01

    A large-scale high-pressure gaseous 3 He polarized target has been developed for use with a high-intensity polarized electron beam at the Stanford Linear Accelerator Center. This target was used successfully in an experiment to study the spin structure of the neutron. The target provided an areal density of about 7x10 21 nuclei/cm 2 and operated at 3 He polarizations between about 30% and 40% for the six-week duration of the experiment. ((orig.))

  2. Apparent rate constant mapping using hyperpolarized [1-(13) C]pyruvate

    DEFF Research Database (Denmark)

    Khegai, O.; Schulte, R. F.; Janich, M. A.

    2014-01-01

    Hyperpolarization of [1-13C]pyruvate in solution allows real-time measurement of uptake and metabolism using MR spectroscopic methods. After injection and perfusion, pyruvate is taken up by the cells and enzymatically metabolized into downstream metabolites such as lactate, alanine, and bicarbona...

  3. Theory of the surface-induced magnetism in liquid 3He

    International Nuclear Information System (INIS)

    Jichu, Hisao; Kuroda, Yoshihiro

    1982-01-01

    A theory of the surface-induced magnetism of liquid 3 He confined in a restricted geometry is presented. In a general model, three different types of contributions to the effective exchange interactions among spins of the 3 He atoms in a solid layer adsorbed on a substrate are distinguished on the basis of the second order perturbation theory; one is from a direct process and the others are mediated by the spins of the 3 He atoms in the remaining bulk liquid. By using a simplified model, the exchange constants are calculated to find that an RKKY-type indirect exchange interaction appears to be most dominant and to explain the observed ferromagnetic tendency. (author)

  4. Direct elastic and inelastic processes produced in the case of He+-He for 3 KeV00

    International Nuclear Information System (INIS)

    Bordenave-Montesquieu, Daniele.

    1980-12-01

    The He + on He collision has been studied by the energy loss method in the 3 to 50 KeV energy range and 0.25 to 3 0 angle range. A detailed description of the experimental device, which has been built for this purpose, is made. Direct elastic and inelastic cross sections are then obtained by integration. A single theoretical model is given, which explains the main features of the elastic differential cross section behaviour [fr

  5. Analysis of Cancer Metabolism by Imaging Hyperpolarized Nuclei: Prospects for Translation to Clinical Research

    Directory of Open Access Journals (Sweden)

    John Kurhanewicz

    2011-02-01

    Full Text Available A major challenge in cancer biology is to monitor and understand cancer metabolism in vivo with the goal of improved diagnosis and perhaps therapy. Because of the complexity of biochemical pathways, tracer methods are required for detecting specific enzyme-catalyzed reactions. Stable isotopes such as 13C or 15N with detection by nuclear magnetic resonance provide the necessary information about tissue biochemistry, but the crucial metabolites are present in low concentration and therefore are beyond the detection threshold of traditional magnetic resonance methods. A solution is to improve sensitivity by a factor of 10,000 or more by temporarily redistributing the populations of nuclear spins in a magnetic field, a process termed hyperpolarization. Although this effect is short-lived, hyperpolarized molecules can be generated in an aqueous solution and infused in vivo where metabolism generates products that can be imaged. This discovery lifts the primary constraint on magnetic resonance imaging for monitoring metabolism—poor sensitivity—while preserving the advantage of biochemical information. The purpose of this report was to briefly summarize the known abnormalities in cancer metabolism, the value and limitations of current imaging methods for metabolism, and the principles of hyperpolarization. Recent preclinical applications are described. Hyperpolarization technology is still in its infancy, and current polarizer equipment and methods are suboptimal. Nevertheless, there are no fundamental barriers to rapid translation of this exciting technology to clinical research and perhaps clinical care.

  6. Polarized 3He Neutron Spin Filters

    Energy Technology Data Exchange (ETDEWEB)

    Sno, William Michael [Indiana Univ., Bloomington, IN (United States)

    2016-01-12

    The goal of this grant to Indiana University and subcontractors at Hamilton College and Wisconsin and the associated Interagency Agreement with NIST was to extend the technique of polarized neutron scattering by the development and application of polarized 3He-based neutron spin filters. This effort was blessed with long-term support from the DOE Office of Science, which started in 2003 and continued until the end of a final no-cost extension of the last 3-year period of support in 2013. The steady support from the DOE Office of Science for this long-term development project was essential to its eventual success. Further 3He neutron spin filter development is now sited at NIST and ORNL.

  7. 3 telsa MRI: successful results with higher field strengths

    International Nuclear Information System (INIS)

    Schmitt, F.; Grosu, D.; Purdy, D.; Salem, K.; Scott, K.T.; Stoeckel, B.; Mohr, C.

    2004-01-01

    The recent development of 3Telsa MRI (3T MRI) has been fueled by the promise of increased signal-to-noise ratio (SNR). Many are excited about the opportunity to no only use the increased SNR for clearer images, but also the change to exchange it for better resolution or faster scans. These possibilities have caused a rapid increase in the market for 3T MRI, where the faster scanning tips an already advantageous economic outlook in favor of the user. As a result, the global market for 3T has grown from a research only market just a few years ago to an ever-increasing clinically oriented customer base. There are, however, significant obstacles to 3T MRI presented by the physics at higher field strength. For example the T1 relaxation times are prolongued with increasing magnet field strength. Further, the increased RF-energy deposition (ASR), the larger chemical shift and the stronger susceptibility effect have to be considered as challenges. It is critical that one looks at both the advantages and disadvantages of using 3T. While there are many issues to address and a number of different methods for doing so, to properly tackle each of these concerns will take time and effort on the part of researchers and clinicians. The optimization of 3T MRI scanning will have to be combined effort, though much work has already been done. The most active area of work to date has been in neuroimaging. Multiple applications have been explored in addition to clinical anatomical imaging, where resolutions is improved showing structure in the brain never before seen in human MRI

  8. Separable interactions and liquid 3He

    International Nuclear Information System (INIS)

    Nijhoff, F.W.

    1984-01-01

    In this thesis, the different phases of liquid 3 He are studied in the presence and absence of magnetic field. It offers microscopic calculations starting from BCS hamiltonians with some additional terms (Zeeman-term to include the magnetic field; an Hubbard-term to include spin fluctuations). A systematic determination of the phase diagram is presented. (Auth.)

  9. Spatial Distortion in MRI-Guided Stereotactic Procedures: Evaluation in 1.5-, 3- and 7-Tesla MRI Scanners.

    Science.gov (United States)

    Neumann, Jan-Oliver; Giese, Henrik; Biller, Armin; Nagel, Armin M; Kiening, Karl

    2015-01-01

    Magnetic resonance imaging (MRI) is replacing computed tomography (CT) as the main imaging modality for stereotactic transformations. MRI is prone to spatial distortion artifacts, which can lead to inaccuracy in stereotactic procedures. Modern MRI systems provide distortion correction algorithms that may ameliorate this problem. This study investigates the different options of distortion correction using standard 1.5-, 3- and 7-tesla MRI scanners. A phantom was mounted on a stereotactic frame. One CT scan and three MRI scans were performed. At all three field strengths, two 3-dimensional sequences, volumetric interpolated breath-hold examination (VIBE) and magnetization-prepared rapid acquisition with gradient echo, were acquired, and automatic distortion correction was performed. Global stereotactic transformation of all 13 datasets was performed and two stereotactic planning workflows (MRI only vs. CT/MR image fusion) were subsequently analysed. Distortion correction on the 1.5- and 3-tesla scanners caused a considerable reduction in positional error. The effect was more pronounced when using the VIBE sequences. By using co-registration (CT/MR image fusion), even a lower positional error could be obtained. In ultra-high-field (7 T) MR imaging, distortion correction introduced even higher errors. However, the accuracy of non-corrected 7-tesla sequences was comparable to CT/MR image fusion 3-tesla imaging. MRI distortion correction algorithms can reduce positional errors by up to 60%. For stereotactic applications of utmost precision, we recommend a co-registration to an additional CT dataset. © 2015 S. Karger AG, Basel.

  10. Comment on "Deep mixing of 3He: reconciling Big Bang and stellar nucleosynthesis".

    Science.gov (United States)

    Balser, Dana S; Rood, Robert T; Bania, T M

    2007-08-31

    Eggleton et al. (Reports, 8 December 2006, p. 1580) reported on a deep-mixing mechanism in low-mass stars caused by a Rayleigh-Taylor instability that destroys all of the helium isotope 3He produced during the star's lifetime. Observations of 3He in planetary nebulae, however, indicate that some stars produce prodigious amounts of 3He. This is inconsistent with the claim that all low-mass stars should destroy 3He.

  11. Measurement of double polarized asymmetries in quasi-elastic processes ${}^3\\vec{He}(\\vec{e},e' d)$ and ${}^3\\vec{He}(\\vec{e},e' p)$

    Energy Technology Data Exchange (ETDEWEB)

    Mihovilovic, Miha [Univ. of Ljubljana (Slovenia)

    2012-01-01

    This thesis is dedicated to a study of a spin-isospin structure of the polarized 3He. First, an introduction to the spin structure of 3He is given, followed by a brief overview of past experiments. The main focus of the thesis is the E05-102 experiment at Jefferson Lab, in which the reactions ${}^3\\vec{He}(\\vec{e},e' d)$ and ${}^3\\vec{He}(\\vec{e},e' p)$ in the quasi-elastic region were studied. The purpose of this experiment was to better understand the effects of the S'- and D-state contributions to the 3He ground-state wave-functions by a precise measurement of beam-target asymmetries Ax and Az in the range of recoil momenta from 0 to about 300 MeV/c. The experimental equipment utilized in these measurements is described, with special attention devoted to the calibration of the hadron spectrometer, BigBite. Results on the measured asymmetries are presented, together with first attempts at their comparison to the state-of-the art Faddeev calculations. The remaining open problems and challenges for future work are also discussed.

  12. 3D printing of MRI compatible components: why every MRI research group should have a low-budget 3D printer.

    Science.gov (United States)

    Herrmann, Karl-Heinz; Gärtner, Clemens; Güllmar, Daniel; Krämer, Martin; Reichenbach, Jürgen R

    2014-10-01

    To evaluate low budget 3D printing technology to create MRI compatible components. A 3D printer is used to create customized MRI compatible components, a loop-coil platform and a multipart mouse fixation. The mouse fixation is custom fit for a dedicated coil and facilitates head fixation with bite bar, anesthetic gas supply and biomonitoring sensors. The mouse fixation was tested in a clinical 3T scanner. All parts were successfully printed and proved MR compatible. Both design and printing were accomplished within a few days and the final print results were functional with well defined details and accurate dimensions (Δ3D printer can be used to quickly progress from a concept to a functional device at very low production cost. While 3D printing technology does impose some restrictions on model geometry, additive printing technology can create objects with complex internal structures that can otherwise not be created by using lathe technology. Thus, we consider a 3D printer a valuable asset for MRI research groups. Copyright © 2014 IPEM. Published by Elsevier Ltd. All rights reserved.

  13. A Bacterial Toxin with Analgesic Properties: Hyperpolarization of DRG Neurons by Mycolactone.

    Science.gov (United States)

    Song, Ok-Ryul; Kim, Han-Byul; Jouny, Samuel; Ricard, Isabelle; Vandeputte, Alexandre; Deboosere, Nathalie; Marion, Estelle; Queval, Christophe J; Lesport, Pierre; Bourinet, Emmanuel; Henrion, Daniel; Oh, Seog Bae; Lebon, Guillaume; Sandoz, Guillaume; Yeramian, Edouard; Marsollier, Laurent; Brodin, Priscille

    2017-07-18

    Mycolactone, a polyketide molecule produced by Mycobacterium ulcerans , is the etiological agent of Buruli ulcer. This lipid toxin is endowed with pleiotropic effects, presents cytotoxic effects at high doses, and notably plays a pivotal role in host response upon colonization by the bacillus. Most remarkably, mycolactone displays intriguing analgesic capabilities: the toxin suppresses or alleviates the pain of the skin lesions it inflicts. We demonstrated that the analgesic capability of mycolactone was not attributable to nerve damage, but instead resulted from the triggering of a cellular pathway targeting AT₂ receptors (angiotensin II type 2 receptors; AT₂R), and leading to potassium-dependent hyperpolarization. This demonstration paves the way to new nature-inspired analgesic protocols. In this direction, we assess here the hyperpolarizing properties of mycolactone on nociceptive neurons. We developed a dedicated medium-throughput assay based on membrane potential changes, and visualized by confocal microscopy of bis-oxonol-loaded Dorsal Root Ganglion (DRG) neurons. We demonstrate that mycolactone at non-cytotoxic doses triggers the hyperpolarization of DRG neurons through AT₂R, with this action being not affected by known ligands of AT₂R. This result points towards novel AT₂R-dependent signaling pathways in DRG neurons underlying the analgesic effect of mycolactone, with the perspective for the development of new types of nature-inspired analgesics.

  14. The cosmic-ray He-3/He-4 ratio from 200 MeV per nucleon(-1) to 3.7 GeV per nucleon(-1)

    DEFF Research Database (Denmark)

    Reimer, O.; Menn, W.; Hof, M.

    1998-01-01

    by their mass using the velocity versus magnetic rigidity technique. The measured He-3/He-4 ratios are corrected to the top of the atmosphere, and a comparison with previous data is given. The observed isotopic composition is found to be generally consistent with the predictions of a standard leaky box model...

  15. Effective mass of liquid 3He using the melting curve data

    International Nuclear Information System (INIS)

    Chaddah, P.; Simmons, R.O.; Illinois Univ., Urbana

    1980-01-01

    Measurements of dp/dt and of the liquid and solid molar volumes along the melting curve of 3 He can be used to obtain information about the Fermi liquid parameter Esub(f) = p 2 sub(f)/2m* of liquid 3 He. Data at temperatures reasonably far above the Neel temperature of the solid, but low enough so that the first finite-temperature correction term in Fermi liquid theory is not large are used. It is shown that in spite of uncertainties in the solid 3 He entropy because of uncertainties in the knowledge of the exchange mechanism, the melting curve data provide a check on the different sets of values for m* quoted in literature. The possible effect of ground state vacancies, whose existence in BCC 3 He has been speculated on this analysis is also discussed. (author)

  16. The nuclear reaction n + 3He -> 1H + 3H as proximity reaction

    International Nuclear Information System (INIS)

    Hilber, H.C.

    1982-01-01

    The present thesis tries to give by means of the nuclear reaction n + 3 He -> 1 H + 3 H as proximity reaction on the three-particle system 3 He + 9 Be -> 1 H + 3 H + 8 Be an experimental verification to the second term of a multiple scattering series. The study of these rescattering effects is of great interest for the present theory of the final-state interaction. At three incident energies (7.08 MeV, 8.98 MeV, and 6.37 MeV) to detector telescopes identify the exit channel of the three-particle system in list-mode coincidence experiments according to protons and tritons. Peaks on the kinematical curves occur. The detailed study of their kinematic behaviour allows to exclude the inconcurrence to the proximity reaction lying cascade decays via intermediate states in 4 He, 9 B, and 11 B. Regarding the Coulomb interaction the experimental results can be also explained in the sense of the classical kinematics by the proximity model. (orig.) [de

  17. A liquid He-3 target system for use at intermediate energies

    International Nuclear Information System (INIS)

    Hassell, D.K.; Abegg, R.; Murdoch, B.T.; van Oers, W.J.H.; Soukup, J.

    1981-04-01

    A liquid 3 He target system with remote instrumentation and handling capabilities has been developed for experiments using the 180-525 MeV TRIUMF cyclotron. Helium-3 gas is liquefied by means of a 4 He cryostat into a cylindrical target cell (4.4 cm diameter, 1.6 cm thick) and maintained during operation at approximately 1.6 K. This provides an areal target density of approximately 2.7 x 10 22 He-3 nuclei/cm 2 (128 mg/cm 2 ), suitable for intermediate energy proton scattering. (author)

  18. Realization of a broad band neutron spin filter with compressed, polarized 3He gas

    International Nuclear Information System (INIS)

    Surkau, R.; Otten, E.W.; Steiner, M.; Tasset, F.; Trautmann, N.

    1997-01-01

    The strongly spin dependent absorption of neutrons in nuclear spin polarized 3 -2pt vector He opens the possibility to polarize beams of thermal and epithermal neutrons. An effective 3 He neutron spin filter (NSF) requires high 3 He nuclear polarization as well as a filter thickness corresponding to a gas amount of the order of 1 bar l. We realized such a filter using direct optical pumping of metastable 3 He * atoms in a 3 He plasma at 1 mbar. Metastable exchange scattering transfers the angular momentum to the whole ensemble of 3 He atoms. At present 3 x 10 18 3 He-atoms/s are polarized up to 64%. Subsequent polarization preserving compression by a two stage compressor system enables to prepare NSF cells of about 300 cm 3 volume with 3 bar of polarized 3 He within 2 h. 3 He polarizations up to 53% were measured in a cell with a filter length of about 15 cm. By this cell a thermal neutron beam from the Mainz TRIGA reactor was polarized. A wavelength selective polarization analysis by means of Bragg scattering revealed a neutron polarization of 84% at a total transmission of 12% for a neutron wavelength of 1 A. (orig.)

  19. Rotational cross sections and rate coefficients of aluminium monoxide AlO(X2Σ+) induced by its collision with He(1 S) at low temperature

    Science.gov (United States)

    Tchakoua, Théophile; Nkot Nkot, Pierre René; Fifen, Jean Jules; Nsangou, Mama; Motapon, Ousmanou

    2018-06-01

    We present the first potential energy surface (PES) for the AlO(X2Σ+)-He(1 S) van der Waals complex. This PES has been calculated at the RCCSD(T) level of theory. The mixed Gaussian/Exponential Extrapolation Scheme of complete basis set [CBS(D,T,Q)] was employed. The PES was fitted using global analytical method. This fitted PES was used subsequently in the close-coupling approach for the computation of the state-to-state collisional excitation cross sections of the fine-structure levels of the AlO-He complex. Collision energies were taken up to 2500 cm-1 and they yield after thermal averaging, state-to-state rate coefficients up to 300 K. The propensity rules between the lowest fine-structure levels were studied. These rules show, on one hand, a strong propensity in favour of odd ΔN transitions, and on the other hand, that cross sections and collisional rate coefficients for Δj = ΔN transitions are larger than those for Δj ≠ ΔN transitions.

  20. A hyperpolarized equilibrium for magnetic resonance.

    Science.gov (United States)

    Hövener, Jan-Bernd; Schwaderlapp, Niels; Lickert, Thomas; Duckett, Simon B; Mewis, Ryan E; Highton, Louise A R; Kenny, Stephen M; Green, Gary G R; Leibfritz, Dieter; Korvink, Jan G; Hennig, Jürgen; von Elverfeldt, Dominik

    2013-01-01

    Nuclear magnetic resonance spectroscopy and imaging (MRI) play an indispensable role in science and healthcare but use only a tiny fraction of their potential. No more than ≈10 p.p.m. of all ¹H nuclei are effectively detected in a 3-Tesla clinical MRI system. Thus, a vast array of new applications lays dormant, awaiting improved sensitivity. Here we demonstrate the continuous polarization of small molecules in solution to a level that cannot be achieved in a viable magnet. The magnetization does not decay and is effectively reinitialized within seconds after being measured. This effect depends on the long-lived, entangled spin-order of parahydrogen and an exchange reaction in a low magnetic field of 10⁻³ Tesla. We demonstrate the potential of this method by fast MRI and envision the catalysis of new applications such as cancer screening or indeed low-field MRI for routine use and remote application.

  1. Plate Tectonic Cycling and Whole Mantle Convection Modulate Earth's 3He/22Ne Ratio

    Science.gov (United States)

    Dygert, N. J.; Jackson, C.; Hesse, M. A.; Tremblay, M. M.; Shuster, D. L.; Gu, J.

    2016-12-01

    3He and 22Ne are not produced in the mantle or fractionated by partial melting, and neither isotope is recycled back into the mantle by subduction of oceanic basalt or sediment. Thus, it is a surprise that large 3He/22Ne variations exist within the mantle and that the mantle has a net elevated 3He/22Ne ratio compared to volatile-rich planetary precursor materials. Depleted subcontinental lithospheric mantle and mid-ocean ridge basalt (MORB) mantle have distinctly higher 3He/22Ne compared to ocean island basalt (OIB) sources ( 4-12.5 vs. 2.5-4.5, respectively) [1,2]. The low 3He/22Ne of OIBs approaches chondritic ( 1) and solar nebula values ( 1.5). The high 3He/22Ne of the MORB mantle is not similar to solar sources or any known family of meteorites, requiring a mechanism for fractionating He from Ne in the mantle and suggesting isolation of distinct mantle reservoirs throughout geologic time. We model the formation of a MORB source with elevated and variable 3He/22Ne though diffusive exchange between dunite channel-hosted basaltic liquids and harzburgite wallrock beneath mid-ocean ridges. Over timescales relevant to mantle upwelling beneath spreading centers, He may diffuse tens to hundreds of meters into wallrock while Ne is relatively immobile, producing a regassed, depleted mantle lithosphere with elevated 3He/22Ne. Subduction of high 3He/22Ne mantle would generate a MORB source with high 3He/22Ne. Regassed, high 3He/22Ne mantle lithosphere has He concentrations 2-3 orders of magnitude lower than undegassed mantle. To preserve the large volumes of high 3He/22Ne mantle required by the MORB source, mixing between subducted and undegassed mantle reservoirs must have been limited throughout geologic time. Using the new 3He/22Ne constraints, we ran a model similar to [3] to quantify mantle mixing timescales, finding they are on the order of Gyr assuming physically reasonable seafloor spreading rates, and that Earth's convecting mantle has lost >99% of its primordial

  2. The mobility of negative ions in superfluid 3He

    International Nuclear Information System (INIS)

    Solomaa, M.

    1982-01-01

    This article reviews recent experimental and theoretical work on the mobility of negative ions in the superfluid A and B phases of liquid 3 He. In the normal Fermi liquid at temperatures below approximately 50 mK and also in the superfluid close to the superfluid transition temperature, Tsub(c), the mobility of a negative ion may simply be considered as limited by the elastic scattering of 3 He quasiparticles. This explains the constancy of the ion mobility in the normal phase. However, underlying the rapid increase of the measured mobility in the superfluid phases there is a subtle quantum-mechanical scattering effect. Detailed solutions of the 3 He quasiparticle-negative ion scattering process in the pair-correlated state provide a simple physical picture of an energy-dependent forward-peaking phenomenon. This yields quantitative theoretical results for the ion mobility in the quasi-isotropic B phase and for the ion mobility tensor in the anisotropic A phase which agree with the experimental data. (author)

  3. T2 Mapping of the Sacroiliac Joints With 3-T MRI: A Preliminary Study.

    Science.gov (United States)

    Lefebvre, Guillaume; Bergère, Antonin; Rafei, Mazen El; Duhamel, Alain; Teixeira, Pedro; Cotten, Anne

    2017-08-01

    The objective of this study was to assess the feasibility of T2 relaxation time measurements of the sacroiliac joints. The sacroiliac joints of 40 patients were imaged by 3-T MRI using an oblique axial multislice multiecho spin-echo T2-weighted sequence. Manual plotting and automatic subdivision of ROIs allowed us to obtain T2 values for up to 48 different areas per patient (posterior and anterior parts, sacral, intermediate, and iliac parts). Intraand interobserver reproducibility of T2 values were calculated after independent assessment by two musculoskeletal radiologists. A total of 1656 measurement sites could be analyzed. Mean (± SD) T2 values were 40.6 ± 6.7 ms and 41.2 ± 6.3 ms for observer 1 and 39.9 ± 6.6 ms for observer 2. The intraobserver intraclass correlation coefficient was 0.72 (95% CI, 0.70-0.74), and the interobserver intraclass correlation coefficient was 0.71 (95% CI, 0.68-0.72). Our study shows the feasibility of T2 relaxation time measurements at the sacroiliac joints.

  4. 4He(γ,dd and 3He(γ,pd reactions in nonlocal covariant model

    Directory of Open Access Journals (Sweden)

    Kasatkin Yu. A.

    2014-03-01

    Full Text Available Photonuclear reaction research is of great interest to obtain information about the structure of nuclei. The investigation of structural effects requires certain insights into the reaction mechanisms, that have to be identified on the basis of the fundamental principles of covariance and gauge invariance. The major achievement of the chosen model is the ability to reproduce the cross-section dependence using the minimal necessary set of parameters. We analyze the two-particle disintegration of 3He nuclei by photons. Our interest was raised by the fact that 3He is the simplest many-particle system which admits an exact solutions. We also consider the process 4He(γ, dd. This process comes at the expense of the quadrupole absorption of γ-rays, while the dipole transition is suppressed. This property is a consequence of the isospin selection as well as the identity of the particles in the final state. Obtained results describe the energy range from threshold (20 MeV to 140 MeV. Therefore, the model mentioned in the paper has the peculiarity to be valid not only for the low-energy regime, but also for higher energies. Present paper is devoted to determine the roles of different reaction mechanisms and to solve problems above.

  5. 3-Tesla MRI: Beneficial visualization of the meniscofemoral ligaments?

    Science.gov (United States)

    Ebrecht, Johanna; Krasny, Andrej; Hartmann, Dinah Maria; Rückbeil, Marcia Viviane; Ritz, Thomas; Prescher, Andreas

    2017-10-01

    Recent investigations have confirmed an important stabilizing and protective function of the meniscofemoral ligaments (MFLs) to the knee joint and suggest a clinical relevance. Concerning their incidences, however, there have been discrepancies between data acquired from cadaveric studies and MRI data using 0.3- to 1.5-Tesla field strengths probably due to lower resolution. This study aims to investigate whether imaging with 3-Tesla magnetic resonance imaging (3-T MRI) is beneficial in gaining information regarding the ligaments' incidence, length, width and anatomic variation. 3-T MRI images of 448 patients (224 males, 224 females, with, respectively, 32 patients of each sex in the age groups: 0-20, 21-30, 31-40, 41-50, 51-60, 61-70, >70years) were retrospectively reviewed. The influence of the parameters 'sex' and 'age' was determined. Whereas 71% of the patients had at least one MFL, 22% had an anterior MFL (aMFL), 53% had a posterior MFL (pMFL) and five percent had coexisting ligaments. The pMFLs were more likely to be present in female patients (P<0.05) but if so, they were longer in the males (P<0.05). The pMFL was categorized according to its insertion on the medial femoral condyle. 3-T MRI enables an excellent illustration of the anatomic variations of pMFLs. By modifying an anatomic classification for radiological use we measured lengths and widths of the MFLs without any difficulties. Despite its increased resolution, 3-T MRI lends no diagnostic benefit in visualizing the course of the aMFL or filigree coexisting ligaments as compared to MRI at lower field strengths. Copyright © 2017 Elsevier B.V. All rights reserved.

  6. Prospective comparison of T2w-MRI and dynamic-contrast-enhanced MRI, 3D-MR spectroscopic imaging or diffusion-weighted MRI in repeat TRUS-guided biopsies

    Energy Technology Data Exchange (ETDEWEB)

    Portalez, Daniel [Clinique Pasteur, 45, Department of Radiology, Toulouse (France); Rollin, Gautier; Mouly, Patrick; Jonca, Frederic; Malavaud, Bernard [Hopital de Rangueil, Department of Urology, Toulouse Cedex 9 (France); Leandri, Pierre [Clinique Saint Jean, 20, Department of Urology, Toulouse (France); Elman, Benjamin [Clinique Pasteur, 45, Department of Urology, Toulouse (France)

    2010-12-15

    To compare T2-weighted MRI and functional MRI techniques in guiding repeat prostate biopsies. Sixty-eight patients with a history of negative biopsies, negative digital rectal examination and elevated PSA were imaged before repeat biopsies. Dichotomous criteria were used with visual validation of T2-weighted MRI, dynamic contrast-enhanced MRI and literature-derived cut-offs for 3D-spectroscopy MRI (choline-creatine-to-citrate ratio >0.86) and diffusion-weighted imaging (ADC x 10{sup 3} mm{sup 2}/s < 1.24). For each segment and MRI technique, results were rendered as being suspicious/non-suspicious for malignancy. Sextant biopsies, transition zone biopsies and at least two additional biopsies of suspicious areas were taken. In the peripheral zones, 105/408 segments and in the transition zones 19/136 segments were suspicious according to at least one MRI technique. A total of 28/68 (41.2%) patients were found to have cancer. Diffusion-weighted imaging exhibited the highest positive predictive value (0.52) compared with T2-weighted MRI (0.29), dynamic contrast-enhanced MRI (0.33) and 3D-spectroscopy MRI (0.25). Logistic regression showed the probability of cancer in a segment increasing 12-fold when T2-weighted and diffusion-weighted imaging MRI were both suspicious (63.4%) compared with both being non-suspicious (5.2%). The proposed system of analysis and reporting could prove clinically relevant in the decision whether to repeat targeted biopsies. (orig.)

  7. HD 185330 — chemically peculiar 3He star in the Kepler field

    Science.gov (United States)

    Niemczura, E.; Vennes, S.; Różański, T.; Pigulski, A.; Hełminiak, K.; Lehmann, H.

    2018-01-01

    We analyzed high-resolution spectra of the chemically peculiar 3He star HD 185330. We determined its atmospheric parameters (Teff, log g, ξ) and constrained its rotation velocity and abundance pattern. In particular, we found a large (×100) phosphorus abundance excess and evidence of 3He and 4He abundance stratification in the atmosphere.

  8. Metastability-exchange optical pumping of 3He for neutron polarizers

    International Nuclear Information System (INIS)

    Gentile, T.R.; Thompson, A.K.; Snow, W.M.

    1995-01-01

    Research is underway at NIST and IU to develop neutron polarizers that are based on polarized 3 He. Such polarizers rely on the strong spin dependence of the cross section for neutron capture by polarized 3 He. Two methods can produce the high density of polarized 3 He gas (10 19 -10 20 cm -3 ) required for an effective neutron polarizer: spin-exchange optical pumping, which is performed directly at high pressure (1-10 bar), and metastability-exchange optical pumping, in which the gas is polarized at low pressure (1 mbar) and then compressed. While we are pursuing both methods, progress in the metastable method will be discussed. The features of the metastable method are the high rate at which the gas can be polarized and the inherent separation of the optical pumping and target cells. In a landmark achievement, researchers at the Univ. of Mainz have developed a piston compressor that can fill a 130 cm 3 cell to a pressure of 7 bar of 45% polarized 3 He gas in 2 hours. We plan to develop a compressor and test it at the NIST Cold Neutron Research Facility. We have constructed a metastable-pumping apparatus at NIST and have obtained 76% polarization with a pumping rate of 1.2 x 10 18 atoms/sec in a 0.4 mbar, 270 cm 3 cell

  9. The electrodisintegration of 3He studied with the 3He(e,e'p)2H and 3He(e,e'd)1H reactions

    International Nuclear Information System (INIS)

    Keizer, P.H.M.

    1986-01-01

    The author presents a survey of experimental and theoretical results for the ground-state properties of 3 He. The formalism of the (e,e'p) and (e,e'd) reactions is presented. A short description of the instrumentation, in particular those elements which are typical for the present study, and of the data analysis is given. This includes a description of the elements required in the 'recoil detection' technique. The kinematics of the experiments and the results are presented. The results are discussed and compared with calculations. (Auth.)

  10. Is e+e- pair emission important in the determination of the 3He+4He S factor?

    Science.gov (United States)

    Snover, K. A.; Hurd, A. E.

    2003-05-01

    We show that the cross section for direct E0 pair emission is related to the cross section for direct E2 photon emission, and is a negligible contribution to the total capture cross section for 3He+4He→7Be. E0 resonance emission, E1 pair emission, and internal conversion are also negligible. Thus there cannot be significant contributions to the 3He+4He→7Be capture cross section at low energies from electromagnetic emission processes other than single photon emission.

  11. The influence of (n-n{sup '})-mixing processes in He*(n)+He(1s{sup 2}) collisions on He*(n) atoms' populations in weakly ionized helium plasmas

    Energy Technology Data Exchange (ETDEWEB)

    Mihajlov, A.A. [Institute of Physics, P.O. Box 57, 11001 Belgrade (Serbia and Montenegro); Ignjatovic, Lj.M. [Institute of Physics, P.O. Box 57, 11001 Belgrade (Serbia)], E-mail: ljuba@phy.bg.ac.yu; Sreckovic, V.A. [Institute of Physics, P.O. Box 57, 11001 Belgrade (Serbia); Djuric, Z. [Silvaco Data Systems, Compass Point, St Ives PE27 5JL (United Kingdom)

    2008-03-15

    The results of semi-classical calculations of rate coefficients of (n-n{sup '})-mixing processes due to collisions of Rydberg atoms He*(n) with He(1s{sup 2}) atoms are presented. It is assumed that these processes are caused by the resonant energy exchange within the electron component of He*(n)+He collision system. The method is realized through the numerical simulation of the (n-n{sup '})-mixing processes, and is applied for calculations of the corresponding rate coefficients. The calculations are performed for the principal quantum numbers n,n{sup '} in ranges 4{<=}n

  12. Energy spectrum of surface electrons over a {sup 3}He – {sup 4}He solution with a spatially non-uniform distribution of the light isotope

    Energy Technology Data Exchange (ETDEWEB)

    Bezsmolnyy, Ya.Yu.; Sokolova, E.S.; Sokolov, S.S. [B.Verkin Institute for Low Temperature Physics and Engineering of the National Academy of Sciences of Ukraine, 47 Prospekt Nauky, 61103 Kharkov (Ukraine); Studart, Nelson [Centro de Ciências Naturais e Humanas, Universidade Federal do ABC, Av. dos Estados, 5001, 09210-580 Santo André, São Paulo (Brazil); Departamento de Física, Universidade Federal de São Carlos, via Washington Luís, km 235, 13565-905 Säo Carlos, São Paulo (Brazil)

    2017-02-15

    The energy gap between the ground and first excited energy levels of surface electrons deposited over a dilute {sup 3}He - {sup 4}He solution is evaluated. Two spatial distributions of {sup 3}He atoms near the free surface solution are considered. One consists of a thin though macroscopic {sup 3}He film and in the other the {sup 3}He concentration varies continuously from the surface inside the liquid. The energy gap is calculated as a function of the parameters of the {sup 3}He spatial distribution for these distributions. It is shown that the energy gap dependence on the distribution parameters allows using measurements of intersubband transitions of the surface electrons to determine the {sup 3}He concentration distribution and, in principle, the nature of the spatial distribution of the light isotope near the surface of the solution.

  13. Structural and functional abnormalities of default mode network in minimal hepatic encephalopathy: a study combining DTI and fMRI.

    Directory of Open Access Journals (Sweden)

    Rongfeng Qi

    Full Text Available BACKGROUND AND PURPOSE: Live failure can cause brain edema and aberrant brain function in cirrhotic patients. In particular, decreased functional connectivity within the brain default-mode network (DMN has been recently reported in overt hepatic encephalopathy (HE patients. However, so far, little is known about the connectivity among the DMN in the minimal HE (MHE, the mildest form of HE. Here, we combined diffusion tensor imaging (DTI and resting-state functional MRI (rs-fMRI to test our hypothesis that both structural and functional connectivity within the DMN were disturbed in MHE. MATERIALS AND METHODS: Twenty MHE patients and 20 healthy controls participated in the study. We explored the changes of structural (path length, tracts count, fractional anisotropy [FA] and mean diffusivity [MD] derived from DTI tractography and functional (temporal correlation coefficient derived from rs-fMRI connectivity of the DMN in MHE patients. Pearson correlation analysis was performed between the structural/functional indices and venous blood ammonia levels/neuropsychological tests scores of patients. All thresholds were set at P<0.05, Bonferroni corrected. RESULTS: Compared to the healthy controls, MHE patients showed both decreased FA and increased MD in the tract connecting the posterior cingulate cortex/precuneus (PCC/PCUN to left parahippocampal gyrus (PHG, and decreased functional connectivity between the PCC/PCUN and left PHG, and medial prefrontal cortex (MPFC. MD values of the tract connecting PCC/PCUN to the left PHG positively correlated to the ammonia levels, the temporal correlation coefficients between the PCC/PCUN and the MPFC showed positive correlation to the digital symbol tests scores of patients. CONCLUSION: MHE patients have both disturbed structural and functional connectivity within the DMN. The decreased functional connectivity was also detected between some regions without abnormal structural connectivity, suggesting that the

  14. Prediction of (n, 3He) cross sections around 14 MeV

    International Nuclear Information System (INIS)

    Atasoy, H.; Doekmen, S.

    1995-01-01

    A comprehensive review of the neutron-induced cross-reactions for (n, 3 He) reactions has been made for the interval of 14 ≤ Z ≤ 84 around 14 MeV neutron energy. For practical purposes, an empirical expression has been found by using the experimental (n, 3 He) cross section values as a function of (N - Z) and (E n - E th ) where (N - Z) is the neutron excess of the target nucleus, E n and E th are the incident neutron energy and the (n, 3 He) threshold energy, respectively. The derived empirical relation gives a good fit with the experimental values

  15. Assessing the transport rate of hyperpolarized pyruvate and lactate from the intra- to the extracellular space.

    Science.gov (United States)

    Reineri, Francesca; Daniele, Valeria; Cavallari, Eleonora; Aime, Silvio

    2016-08-01

    The use of [1-(13) C]pyruvate hyperpolarized by means of dynamic nuclear polarization provides a direct way to track the metabolic transformations of this metabolite in vivo and in cell cultures. The identification of the intra- and extracellular contributions to the (13) C NMR resonances is not straightforward. In order to obtain information about the rate of pyruvate and lactate transport through the cellular membrane, we set up a method that relies on the sudden 'quenching' of the extracellular metabolites' signal. The paramagnetic Gd-tetraazacyclododecane triacetic acid (Gd-DO3A) complex was used to dramatically decrease the longitudinal relaxation time constants of the (13) C-carboxylate resonances of both pyruvate and lactate. When Gd-DO3A was added to an MCF-7 cellular culture, which had previously received a dose of hyperpolarized [1-(13) C]pyruvate, the contributions of the extracellular pyruvate and lactate signals were deleted. From the analysis of the decay curves of the (13) C-carboxylate resonances of pyruvate and lactate it was possible to extract information about the exchange rate of the two metabolites across the cellular membrane. In particular, it was found that, in the reported experimental conditions, the lactate transport from the intra- to the extracellular space is not much lower than the rate of lactate formation. The method reported herein is non-destructive and it could be translated to in vivo studies. It opens a route for the use of hyperpolarized pyruvate to assess altered activity of carboxylate transporter proteins that may occur in pathological conditions. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  16. A comparison of quantitative methods for clinical imaging with hyperpolarized (13)C-pyruvate.

    Science.gov (United States)

    Daniels, Charlie J; McLean, Mary A; Schulte, Rolf F; Robb, Fraser J; Gill, Andrew B; McGlashan, Nicholas; Graves, Martin J; Schwaiger, Markus; Lomas, David J; Brindle, Kevin M; Gallagher, Ferdia A

    2016-04-01

    Dissolution dynamic nuclear polarization (DNP) enables the metabolism of hyperpolarized (13)C-labelled molecules, such as the conversion of [1-(13)C]pyruvate to [1-(13)C]lactate, to be dynamically and non-invasively imaged in tissue. Imaging of this exchange reaction in animal models has been shown to detect early treatment response and correlate with tumour grade. The first human DNP study has recently been completed, and, for widespread clinical translation, simple and reliable methods are necessary to accurately probe the reaction in patients. However, there is currently no consensus on the most appropriate method to quantify this exchange reaction. In this study, an in vitro system was used to compare several kinetic models, as well as simple model-free methods. Experiments were performed using a clinical hyperpolarizer, a human 3 T MR system, and spectroscopic imaging sequences. The quantitative methods were compared in vivo by using subcutaneous breast tumours in rats to examine the effect of pyruvate inflow. The two-way kinetic model was the most accurate method for characterizing the exchange reaction in vitro, and the incorporation of a Heaviside step inflow profile was best able to describe the in vivo data. The lactate time-to-peak and the lactate-to-pyruvate area under the curve ratio were simple model-free approaches that accurately represented the full reaction, with the time-to-peak method performing indistinguishably from the best kinetic model. Finally, extracting data from a single pixel was a robust and reliable surrogate of the whole region of interest. This work has identified appropriate quantitative methods for future work in the analysis of human hyperpolarized (13)C data. © 2016 The Authors. NMR in Biomedicine published by John Wiley & Sons Ltd.

  17. Measurements of the osmotic pressure in liquid mixtures of 3He and 4He near the lambda line and tricritical point

    International Nuclear Information System (INIS)

    Gearhart, C.A. Jr.

    1977-01-01

    Values of the concentration susceptibility (par. deltax/par. deltaΔ)/sub T,P/ near the lambda line and tricritical point in liquid mixtures of 3He and 4 He were calculated from measurements of osmotic pressure differences. Measurements were made by inducing a small 3 He mole fraction difference Δx between two chambrs separated by a pressure transducer, and measuring the resulting osmotic pressure difference as a function of temperature

  18. Measurements of linestrengths, N2-, Ar-, He- and self-broadening coefficients of acetylene in the ν4+ν5 combination band using a cw quantum cascade laser

    KAUST Repository

    Sajid, Muhammad Bilal; Es-sebbar, Et-touhami; Farooq, Aamir

    2014-01-01

    Linestrengths, N2-, Ar-, He- and self-broadening coefficients of acetylene have been measured at 296K in the P branch of the ν4+ν5 combination band for 25 rotational transitions. The effect of gas temperature is studied over 296-683K for five

  19. Removing gaseous contaminants in 3He by cryogenic stripping

    International Nuclear Information System (INIS)

    Benapfl, M.; Biltoft, P.; Coombs, A.

    1995-01-01

    The Tritium Operations Group at LLNL, Tritium Facility has recently developed a 3 He recovery system to remove argon, xenon, neon, hydrogen, and all other contaminants from the 3 He stream in an Accelerator Production of Tritium (APT) experimental apparatus. In this paper the authors will describe in detail the background information, technical requirements, the design approach, and the results of their experimental tests. The authors believe this gas purification system may have other applications as it provides at a reasonable cost an efficient method for purification of gaseous helium

  20. Clinical utility of apparent diffusion coefficient values obtained using high b-value when diagnosing prostate cancer using 3 tesla MRI: comparison between ultra-high b-value (2000 s/mm²) and standard high b-value (1000 s/mm²).

    Science.gov (United States)

    Kitajima, Kazuhiro; Takahashi, Satoru; Ueno, Yoshiko; Yoshikawa, Takeshi; Ohno, Yoshiharu; Obara, Makoto; Miyake, Hideaki; Fujisawa, Masato; Sugimura, Kazuro

    2012-07-01

    To determine whether the apparent diffusion coefficient (ADC) obtained using b = 2000 s/mm(2) upon 3 Tesla (T) diffusion-weighted MRI is superior to b = 1000 s/mm(2) for discriminating malignant from normal prostate tissue and predicting the aggressiveness of prostate cancer, using histopathological findings of radical prostatectomy as a reference. Eighty prostate cancer patients underwent preoperative 3T MRI including diffusion weighted imaging with b-values of 0, 1000, and 2000 s/mm(2) . ADCs were measured for malignant lesions and normal sites on three sets of ADC maps calculated with monoexponential fitting between b = 0 and 1000, 0 and 2000, and 1000 and 2000, respectively. The relationship between the ADC and Gleason score was evaluated. The areas under the ROC curves for b = 0,1000, b = 0,2000, and b = 1000,2000 were 0.896, 0.937, and 0.857, respectively, in the peripheral zone (PZ) and 0.877, 0.889, and 0.731, respectively, in the transition zone (TZ). The difference between b = 0,1000 and b = 0,2000 was significant in PZ (P = 0.033), but not in TZ (P = 0.84). Weak but significant negative correlations were identified between ADCs and Gleason score in both PZ and TZ cancer at b = 0,1000 and b = 0,2000 (r = -0.323 to -0.341). For 3T MRI, ADCs using b = 0,2000 are more accurate than b = 0,1000 for diagnosing PZ cancer, and as accurate for TZ cancer. Copyright © 2012 Wiley Periodicals, Inc.