  1. Systematic review: Radiological and histological evidence of cochlear implant insertion trauma in adult patients.

    Science.gov (United States)

    Hoskison, Emma; Mitchell, Scott; Coulson, Chris

    2017-07-01

    Cochlear implantation (CI) has developed from its origins in the 1980s. Initially, CI was for profound bilateral hearing impairment. However, candidacy for CI have become more widespread in recent years with unilateral implantation and an emphasis on hearing preservation. Evidence supports full electrode insertion in an atraumatic fashion into the scala tympani (ST) provides optimal hearing outcomes. The main aim of this systematic review was to elucidate the degree of trauma associated with CI insertion. A systematic literature search was undertaken using PubMed Medline. A grading system described by Eshraghi was used to classify cochlear trauma. Both radiological and histological studies were included. Twenty one papers were identified which were relevant to our search. In total, 653 implants were inserted and 115 (17.6%) showed evidence of trauma. The cochleas with trauma had basilar membrane elevation in 5.2%, ruptured in 5.2%, the electrode passed from the ST to the SV in 84.4% and there was grade 4 trauma in 5.2%. The studies used a variety of histological and radiological methods to assess for evidence of trauma in both cadaveric temporal bones and live recipients. Minimizing cochlear trauma during implant insertion is important to preserve residual hearing and optimize audiological performance. An overall 17.6% trauma rate suggests that CI insertion could be improved with more accurate and consistent electrode insertion such as in the form of robotic guidance. The correlation of cochlea trauma with post-operative hearing has yet to be determined.

  2. An image database structure for pediatric radiology

    International Nuclear Information System (INIS)

    Mankovich, N.J.

    1987-01-01

    The operation of the Clinical Radiology Imaging System (CRIS) in Pediatric Radiology at UCLA relies on the orderly flow of text and image data among the three basic subsystems including acquisition, storage, and display. CRIS provides the radiologist, clinician, and technician with data at clinical image workstations by maintaining comprehensive database. CRIS is made up of sub-systems, each composed of one more programs or tasks which operate in parallel on a VAX-11/750 microcomputer in Pediatric Radiology. Tasks are coordinated through dynamic data structures that include system event flags and disk-resident queues. This report outlines: (1) the CRIS data model, (2) the flow of information among CRIS components, (3) the underlying database structures which support the acquisition, display, and storage of text and image information, and (4) current database statistics

  3. Evaluating cochlear implant trauma to the scala vestibuli.

    Science.gov (United States)

    Adunka, O; Kiefer, J; Unkelbach, M H; Radeloff, A; Gstoettner, W

    2005-04-01

    Placement of cochlear implant electrodes into the scala vestibuli may be intentional, e.g. in case of blocked scala tympani or unintentional as a result of trauma to the basilar membrane or erroneous location of the cochieostomy. The aim of this study was to evaluate the morphological consequences and cochlear trauma after implantation of different cochlear implant electrode arrays in the scala vestibuli. Human temporal bone study with histological and radiological evaluation. Twelve human cadaver temporal bones were implanted with different cochlear implant electrodes. Implanted bones were processed using a special method to section undecalcified bone. Cochlear trauma and intracochlear positions. All implanted electrodes were implanted into the scala vestibuli using a special approach that allows direct scala vestibuli insertions. Fractures of the osseous spiral lamina were evaluated in some bones in the basal cochlear regions. In most electrodes, delicate structures of the organ of Corti were left intact, however, Reissner's membrane was destroyed in all specimens and the electrode lay upon the tectorial membrane. In some bones the organ of Corti was destroyed. Scala vestibuli insertions did not cause severe trauma to osseous or neural structures, thus preserving the basis for electrostimulation of the cochlea. However, destruction of Reissner's membrane and impact on the Organ of Corti can be assumed to destroy residual hearing.

  4. Radiology

    International Nuclear Information System (INIS)

    Bigot, J.M.; Moreau, J.F.; Nahum, H.; Bellet, M.

    1990-01-01

    The 17th International Congress of Radiology was conducted in two separate scientific sessions, one for radiodiagnosis and one for radiation oncology. Topics covered are: Radiobiology -radioprotection; imaging and data processing; contrast media; MRI; nuclear medicine; radiology and disasters; radiology of tropical diseases; cardiovascular radiology; interventional radiology; imaging of trauma; imaging of chest, gastro-intestinal tract, breast and genito-urinary tract; imaging in gynecology;imaging in oncology; bone and joint radiology; head and neck-radiology; neuro-radiology. (H.W.). refs.; fig.; tabs

  5. Radiologic and functional evaluation of electrode dislocation from the scala tympani to the scala vestibuli in patients with cochlear implants.

    Science.gov (United States)

    Fischer, N; Pinggera, L; Weichbold, V; Dejaco, D; Schmutzhard, J; Widmann, G

    2015-02-01

    Localization of the electrode after cochlear implantation seems to have an impact on auditory outcome, and conebeam CT has emerged as a reliable method for visualizing the electrode array position within the cochlea. The aim of this retrospective study was to evaluate the frequency and clinical impact of scalar dislocation of various electrodes and surgical approaches and to evaluate its influence on auditory outcome. This retrospective single-center study analyzed a consecutive series of 63 cochlear implantations with various straight electrodes. The placement of the electrode array was evaluated by using multiplanar reconstructed conebeam CT images. For the auditory outcome, we compared the aided hearing thresholds and the charge units of maximum comfortable loudness level at weeks 6, 12, and 24 after implantation. In 7.9% of the cases, the electrode array showed scalar dislocation. In all cases, the electrode array penetrated the basal membrane within 45° of the electrode insertion. All 3 cases of cochleostomy were dislocated in the first 45° segment. No hearing differences were noted, but the charge units of maximum comfortable loudness level seemed to increase with time in patients with dislocations. The intracochlear dislocation rate of various straight electrodes detected by conebeam CT images is relatively low. Scalar dislocation may not negatively influence the hearing threshold but may require an increase of the necessary stimulus charge and should be reported by the radiologist. © 2015 by American Journal of Neuroradiology.

  6. Improving Communication of Diagnostic Radiology Findings through Structured Reporting

    Science.gov (United States)

    Panicek, David M.; Berk, Alexandra R.; Li, Yuelin; Hricak, Hedvig

    2011-01-01

    Purpose: To compare the content, clarity, and clinical usefulness of conventional (ie, free-form) and structured radiology reports of body computed tomographic (CT) scans, as evaluated by referring physicians, attending radiologists, and radiology fellows at a tertiary care cancer center. Materials and Methods: The institutional review board approved the study as a quality improvement initiative; no written consent was required. Three radiologists, three radiology fellows, three surgeons, and two medical oncologists evaluated 330 randomly selected conventional and structured radiology reports of body CT scans. For nonradiologists, reports were randomly selected from patients with diagnoses relevant to the physician’s area of specialization. Each physician read 15 reports in each format and rated both the content and clarity of each report from 1 (very dissatisfied or very confusing) to 10 (very satisfied or very clear). By using a previously published radiology report grading scale, physicians graded each report’s effectiveness in advancing the patient’s position on the clinical spectrum. Mixed-effects models were used to test differences between report types. Results: Mean content satisfaction ratings were 7.61 (95% confidence interval [CI]: 7.12, 8.16) for conventional reports and 8.33 (95% CI: 7.82, 8.86) for structured reports, and the difference was significant (P radiology.rsna.org/lookup/suppl/doi:10.1148/radiol.11101913/-/DC1 PMID:21518775

  7. Radiology

    International Nuclear Information System (INIS)

    Edholm, P.R.

    1990-01-01

    This is a report describing diagnostic techniques used in radiology. It describes the equipment necessary for, and the operation of a radiological department. Also is described the standard methods used in radiodiagnosis. (K.A.E.)

  8. Incorporating intelligence into structured radiology reports

    Science.gov (United States)

    Kahn, Charles E.

    2014-03-01

    The new standard for radiology reporting templates being developed through the Integrating the Healthcare Enterprise (IHE) and DICOM organizations defines the storage and exchange of reporting templates as Hypertext Markup Language version 5 (HTML5) documents. The use of HTML5 enables the incorporation of "dynamic HTML," in which documents can be altered in response to their content. HTML5 documents can employ JavaScript, the HTML Document Object Model (DOM), and external web services to create intelligent reporting templates. Several reporting templates were created to demonstrate the use of scripts to perform in-template calculations and decision support. For example, a template for adrenal CT was created to compute contrast washout percentage from input values of precontrast, dynamic postcontrast, and delayed adrenal nodule attenuation values; the washout value can used to classify an adrenal nodule as a benign cortical adenoma. Dynamic templates were developed to compute volumes and apply diagnostic criteria, such as those for determination of internal carotid artery stenosis. Although reporting systems need not use a web browser to render the templates or their contents, the use of JavaScript creates innumerable opportunities to construct highly sophisticated HTML5 reporting templates. This report demonstrates the ability to incorporate dynamic content to enhance the use of radiology reporting templates.

  9. Radiology

    International Nuclear Information System (INIS)

    Lissner, J.

    1985-01-01

    Diagnostic radiology is still the foremost of all innovative medical disciplines. This has many advantages but also some handicaps, e.g. the siting problem of medical equipment whose clinical potential is not fully known. This applies in particular to nuclear spin tomography, where the Laender governments and the Scientific Council seen to agree that all universities should have the appropriate equipment as soon as possible in order to intensify interdisciplinary research. Formerly, in the case of computerized tomography, there was less readiness. As a result, the siting of CT equipment is less organically structured. A special handicap of innovative fields is the problem of training and advanced training. The Chamber of Medicine and the Association of Doctors Participating in the Health Insurance Plan have issued regulations aimed at a better standardisation in this field. (orig.) [de

  10. Impaired perception of temporal fine structure and musical timbre in cochlear implant users.

    Science.gov (United States)

    Heng, Joseph; Cantarero, Gabriela; Elhilali, Mounya; Limb, Charles J

    2011-10-01

    Cochlear implant (CI) users demonstrate severe limitations in perceiving musical timbre, a psychoacoustic feature of sound responsible for 'tone color' and one's ability to identify a musical instrument. The reasons for this limitation remain poorly understood. In this study, we sought to examine the relative contributions of temporal envelope and fine structure for timbre judgments, in light of the fact that speech processing strategies employed by CI systems typically employ envelope extraction algorithms. We synthesized "instrumental chimeras" that systematically combined variable amounts of envelope and fine structure in 25% increments from two different source instruments with either sustained or percussive envelopes. CI users and normal hearing (NH) subjects were presented with 150 chimeras and asked to determine which instrument the chimera more closely resembled in a single-interval two-alternative forced choice task. By combining instruments with similar and dissimilar envelopes, we controlled the valence of envelope for timbre identification and compensated for envelope reconstruction from fine structure information. Our results show that NH subjects utilize envelope and fine structure interchangeably, whereas CI subjects demonstrate overwhelming reliance on temporal envelope. When chimeras were created from dissimilar envelope instrument pairs, NH subjects utilized a combination of envelope (p = 0.008) and fine structure information (p = 0.009) to make timbre judgments. In contrast, CI users utilized envelope information almost exclusively to make timbre judgments (p < 0.001) and ignored fine structure information (p = 0.908). Interestingly, when the value of envelope as a cue was reduced, both NH subjects and CI users utilized fine structure information to make timbre judgments (p < 0.001), although the effect was quite weak in CI users. Our findings confirm that impairments in fine structure processing underlie poor perception of musical timbre in CI

  11. A database structure for radiological optimization analyses of decommissioning operations

    International Nuclear Information System (INIS)

    Zeevaert, T.; Van de Walle, B.

    1995-09-01

    The structure of a database for decommissioning experiences is described. Radiological optimization is a major radiation protection principle in practices and interventions, involving radiological protection factors, economic costs, social factors. An important lack of knowledge with respect to these factors exists in the domain of the decommissioning of nuclear power plants, due to the low number of decommissioning operations already performed. Moreover, decommissioning takes place only once for a installation. Tasks, techniques, and procedures are in most cases rather specific, limiting the use of past experiences in the radiological optimization analyses of new decommissioning operations. Therefore, it is important that relevant data or information be acquired from decommissioning experiences. These data have to be stored in a database in a way they can be used efficiently in ALARA analyses of future decommissioning activities

  12. Radiology

    International Nuclear Information System (INIS)

    Sykora, A.

    2006-01-01

    In this text-book basic knowledge about radiology, biomedical diagnostic methods (radiography, computer tomography), nuclear medicine and safety and radiation protection of personnel on the radiodiagnostic place of work are presented

  13. Cochlear Implants

    Science.gov (United States)

    ... NIDCD A cochlear implant is a small, complex electronic device that can help to provide a sense ... Hearing Aids Retinitis Pigmentosa - National Eye Institute Telecommunications Relay Services Usher Syndrome Your Baby's Hearing Screening News ...

  14. Radiology

    International Nuclear Information System (INIS)

    Meyers, M.A.

    1989-01-01

    This paper reports on disease processes originating within the alimentary tract, may extend through the extraperitoneal spaces, and abnormalities primarily arising within other extraperitoneal sites may significantly affect the bowel. Symptoms and signs may be obscure, delayed, or nonspecific, and the area is generally not accessible to auscultation, palpation, or percussion. Radiologic evaluation thus plays a critical role

  15. Imaging and radiology

    Science.gov (United States)

    Interventional radiology; Diagnostic radiology; X-ray imaging ... DIAGNOSTIC RADIOLOGY Diagnostic radiology helps health care professionals see structures inside your body. Doctors that specialize in the interpretation ...

  16. Conductive Hearing Loss Has Long-Lasting Structural and Molecular Effects on Presynaptic and Postsynaptic Structures of Auditory Nerve Synapses in the Cochlear Nucleus.

    Science.gov (United States)

    Clarkson, Cheryl; Antunes, Flora M; Rubio, Maria E

    2016-09-28

    Sound deprivation by conductive hearing loss increases hearing thresholds, but little is known about the response of the auditory brainstem during and after conductive hearing loss. Here, we show in young adult rats that 10 d of monaural conductive hearing loss (i.e., earplugging) leads to hearing deficits that persist after sound levels are restored. Hearing thresholds in response to clicks and frequencies higher than 8 kHz remain increased after a 10 d recovery period. Neural output from the cochlear nucleus measured at 10 dB above threshold is reduced and followed by an overcompensation at the level of the lateral lemniscus. We assessed whether structural and molecular substrates at auditory nerve (endbulb of Held) synapses in the cochlear nucleus could explain these long-lasting changes in hearing processing. During earplugging, vGluT1 expression in the presynaptic terminal decreased and synaptic vesicles were smaller. Together, there was an increase in postsynaptic density (PSD) thickness and an upregulation of GluA3 AMPA receptor subunits on bushy cells. After earplug removal and a 10 d recovery period, the density of synaptic vesicles increased, vesicles were also larger, and the PSD of endbulb synapses was larger and thicker. The upregulation of the GluA3 AMPAR subunit observed during earplugging was maintained after the recovery period. This suggests that GluA3 plays a role in plasticity in the cochlear nucleus. Our study demonstrates that sound deprivation has long-lasting alterations on structural and molecular presynaptic and postsynaptic components at the level of the first auditory nerve synapse in the auditory brainstem. Despite being the second most prevalent form of hearing loss, conductive hearing loss and its effects on central synapses have received relatively little attention. Here, we show that 10 d of monaural conductive hearing loss leads to an increase in hearing thresholds, to an increased central gain upstream of the cochlear nucleus at

  17. Radiologic imaging of the renal parenchyma structure and function.

    Science.gov (United States)

    Grenier, Nicolas; Merville, Pierre; Combe, Christian

    2016-06-01

    Radiologic imaging has the potential to identify several functional and/or structural biomarkers of acute and chronic kidney diseases that are useful diagnostics to guide patient management. A renal ultrasound examination can provide information regarding the gross anatomy and macrostructure of the renal parenchyma, and ultrasound imaging modalities based on Doppler or elastography techniques can provide haemodynamic and structural information, respectively. CT is also able to combine morphological and functional information, but the use of CT is limited due to the required exposure to X-ray irradiation and a risk of contrast-induced nephropathy following intravenous injection of a radio-contrast agent. MRI can be used to identify a wide range of anatomical and physiological parameters at the tissue and even cellular level, such as tissue perfusion, oxygenation, water diffusion, cellular phagocytic activity, tissue stiffness, and level of renal filtration. The ability of MRI to provide valuable information for most of these parameters within a renal context is still in development and requires more clinical experience, harmonization of technical procedures, and an evaluation of reliability and validity on a large scale.

  18. Cochlear Implant

    Directory of Open Access Journals (Sweden)

    Mehrnaz Karimi

    1992-04-01

    Full Text Available People with profound hearing loss are not able to use some kinds of conventional amplifiers due to the nature of their loss . In these people, hearing sense is stimulated only when the auditory nerve is activated via electrical stimulation. This stimulation is possible through cochlear implant. In fact, for the deaf people who have good mental health and can not use surgical and medical treatment and also can not benefit from air and bone conduction hearing aids, this device is used if they have normal central auditory system. The basic parts of the device included: Microphone, speech processor, transmitter, stimulator and receiver, and electrode array.

  19. Fine structure of long-term changes in the cochlear nucleus after acoustic overstimulation: chronic degeneration and new growth of synaptic endings.

    Science.gov (United States)

    Kim, J J; Gross, J; Potashner, S J; Morest, D K

    2004-09-15

    The companion study showed that acoustic overstimulation of adult chinchillas, with a noise level sufficient to damage the cochlea, led to cytological changes and degeneration of synaptic endings in the cochlear nucleus within 1-16 weeks. In the present study, the same stimulus was used to study the long-term effects on the fine structure of synaptic endings in the cochlear nucleus. For periods of 6 and 8 months after a single exposure to a damaging noise level, there ensued a chronic, continuing process of neurodegeneration involving excitatory and inhibitory synaptic endings. Electron microscopic observations demonstrated freshly occurring degeneration even as late as 8 months. Degeneration was widespread in the neuropil and included the synapses on the globular bushy cell, which forms part of the main ascending auditory pathway. Neurodegeneration was accompanied by newly formed synaptic endings, which repopulated some of the sites vacated previously by axosomatic endings on globular bushy cells. Many of these synaptic endings must arise from central interneurons. The findings suggest that overstimulation can induce a self-sustaining condition of progressive neurodegeneration accompanied by a new growth of synaptic endings. Noise-induced hearing loss thus may progress as a neurodegenerative disease with the capacity for synaptic reorganization within the cochlear nucleus.

  20. Motion of organ of Corti structures in the gerbil cochlear apex, measured with a commercial optical coherence tomography (OCT) system

    Science.gov (United States)

    Ravicz, Michael E.; Cho, Nam-Hyun; Maftoon, Nima; Puria, Sunil

    2018-05-01

    Recent developments in Optical Coherence Tomography (OCT) allow measurements of cochlear motions through the bony cochlear wall without holes at spatial resolutions approaching about 10 µm. Measurements to date have been made with custom OCT systems with long development times. We present measurements made with a commercial OCT system driven by custom software (VibOCT) that facilitates near real-time frequency response measurements. The 905-nm wavelength laser and high-speed (100 kHz) camera provide higher axial resolution (3 µm in air) and temporal resolution than previous studies and a sub-nanometer noise floor in air. We gathered anatomical images of the gerbil cochlear apex in vivo at higher resolution than available previously, sufficient to resolve individual outer hair cells, pillar cells, tunnel of Corti and inner sulcus regions. Images from the 3rd apical turn show a bulging of Reissners membrane in vivo that flattened post-mortem with a concomitant reduction in the distance between the Henson cell border and the stria vascularis wall. Vibrometry of the organ of Corti shows a low-pass characteristic in-vivo and post-mortem with a traveling wave-like phase delay similar to a recent study rather than the sharp tuning seen more basally. This system can provide valuable information on cochlear function, which is also useful for the development of detailed cochlear models of the passive and active gerbil apex.

  1. Consensus conference on core radiological parameters to describe lumbar stenosis - an initiative for structured reporting

    Energy Technology Data Exchange (ETDEWEB)

    Andreisek, Gustav; Winklhofer, Sebastian F.X. [University Hospital Zurich, Department of Radiology, Zurich (Switzerland); Deyo, Richard A. [Oregon Health and Science University, Portland, OR (United States); Jarvik, Jeffrey G. [University of Washington, Seattle, WA (United States); Porchet, Francois [Schulthess Klinik, Zuerich (Switzerland); Steurer, Johann [University Hospital Zurich, Horten Center for patient oriented research and knowledge transfer, Zurich (Switzerland); Collaboration: On behalf of the LSOS working group

    2014-12-15

    To define radiological criteria and parameters as a minimum standard in a structured radiological report for patients with lumbar spinal stenosis (LSS) and to identify criteria and parameters for research purposes. All available radiological criteria and parameters for LSS were identified using systematic literature reviews and a Delphi survey. We invited to the consensus meeting, and provided data, to 15 internationally renowned experts from different countries. During the meeting, these experts reached consensus in a structured and systematic discussion about a core list of radiological criteria and parameters for standard reporting. We identified a total of 27 radiological criteria and parameters for LSS. During the meeting, the experts identified five of these as core items for a structured report. For central stenosis, these were ''compromise of the central zone'' and ''relation between fluid and cauda equina''. For lateral stenosis, the group agreed that ''nerve root compression in the lateral recess'' was a core item. For foraminal stenosis, we included ''nerve root impingement'' and ''compromise of the foraminal zone''. As a minimum standard, five radiological criteria should be used in a structured radiological report in LSS. Other parameters are well suited for research. (orig.)

  2. Scala vestibuli cochlear implantation in patients with partially ossified cochleas.

    Science.gov (United States)

    Berrettini, Stefano; Forli, Francesca; Neri, Emanuele; Segnini, Giovanni; Franceschini, Stefano Sellari

    2002-11-01

    Partial cochlear obstruction is a relatively common finding in candidates for cochlear implants and frequently involves the inferior segment of the scala tympani in the basal turn of the cochlea. In such patients, the scala vestibuli is often patent and offers an alternative site for implantation. The current report describes two patients with such partial obstruction of the inferior segment of the basal cochlear turn, caused in one case by systemic vasculitis (Takayasu's disease) and in the other by obliterative otosclerosis. A scala vestibuli implantation allowed for complete insertion of the electrode array. No problems were encountered during the surgical procedures and the good post-operative hearing and communicative outcomes achieved were similar to those reported in patients without cochlear ossification. The importance of accurate pre-operative radiological study of the inner ear is underscored, to disclose the presence and define the features of the cochlear ossification and ultimately to properly plan the surgical approach.

  3. Language structures used by kindergartners with cochlear implants: relationship to phonological awareness, lexical knowledge and hearing loss.

    Science.gov (United States)

    Nittrouer, Susan; Sansom, Emily; Low, Keri; Rice, Caitlin; Caldwell-Tarr, Amanda

    2014-01-01

    Listeners use their knowledge of how language is structured to aid speech recognition in everyday communication. When it comes to children with congenital hearing loss severe enough to warrant cochlear implants (CIs), the question arises of whether these children can acquire the language knowledge needed to aid speech recognition, in spite of only having spectrally degraded signals available to them. That question was addressed in the present study. Specifically, there were three goals: (1) to compare the language structures used by children with CIs to those of children with normal hearing (NH); (2) to assess the amount of variance in the language measures explained by phonological awareness and lexical knowledge; and (3) to assess the amount of variance in the language measures explained by factors related to the hearing loss itself and subsequent treatment. Language samples were obtained and transcribed for 40 children who had just completed kindergarten: 19 with NH and 21 with CIs. Five measures were derived from Systematic Analysis of Language Transcripts: (1) mean length of utterance in morphemes, (2) number of conjunctions, excluding and, (3) number of personal pronouns, (4) number of bound morphemes, and (5) number of different words. Measures were also collected on phonological awareness and lexical knowledge. Statistics examined group differences, as well as the amount of variance in the language measures explained by phonological awareness, lexical knowledge, and factors related to hearing loss and its treatment for children with CIs. Mean scores of children with CIs were roughly one standard deviation below those of children with NH on all language measures, including lexical knowledge, matching outcomes of other studies. Mean scores of children with CIs were closer to two standard deviations below those of children with NH on two out of three measures of phonological awareness (specifically those related to phonemic structure). Lexical knowledge

  4. Radiology as part of an objective structured clinical examination on clinical skills

    Energy Technology Data Exchange (ETDEWEB)

    Berk, I.A.H. van den, E-mail: i.a.h.van_den_berk@lumc.nl [Department of Radiology, Leiden University Medical Centre, Postbus 9600, 2300 RC Leiden (Netherlands); Ridder, J.M.M. van de, E-mail: J.M.M.vandeRidder@umcutrecht.nl [School of Medical Sciences, University Medical Centre Utrecht, Heidelberglaan 100, 3584 CX Utrecht (Netherlands); Schaik, J.P.J. van, E-mail: J.P.J.vanSchaik@umcutrecht.nl [Department of Radiology, University Medical Centre Utrecht, Heidelberglaan 100 E01-132, 3584 CX Utrecht (Netherlands)

    2011-06-15

    Introduction: An objective structured clinical examination (OSCE) assessess clinical competence in a standardised and context related manner. Compared with written tests, OSCE's are more susceptible to reliability errors because of the use of multiple cases and multiple examiners. In the pre-clinical phase of the medical curriculum of the University Medical Centre Utrecht, an OSCE is organised as a medical consult. We evaluated the radiology station. Method: Four questions were formulated: {center_dot}What is the internal consistency of the items of the radiology station? {center_dot}How do the scores on the radiology station compare with the scores on the test excluding radiology? {center_dot}How do different cases differ in scores? {center_dot}What are the differences in score between the examiners? We analysed the OSCE results of second year medical students in 2004. Results: Two hundred and sixty-five students were examined in the OSCE in 2004. Ninty-three Students were examined in the radiology station. Cronbach's alpha coefficient for the radiology station was 0.92. The average score for the radiology station was 3.8 (0.87). The average score for the test without radiology was 3.9 (0.32). The range of the average scores for the six different cases was 0.5 (3.6-4.1). The range of the average scores for the five examiners was 1.0 (3.3-4.3). Conclusion: The internal consistency of the items in the radiology station is good. The average score for the radiology station is similar to that of the other stations. The range of the scores between the different cases was relatively small. The range of the scores between the different examiners was clearly larger.

  5. Radiology as part of an objective structured clinical examination on clinical skills

    International Nuclear Information System (INIS)

    Berk, I.A.H. van den; Ridder, J.M.M. van de; Schaik, J.P.J. van

    2011-01-01

    Introduction: An objective structured clinical examination (OSCE) assessess clinical competence in a standardised and context related manner. Compared with written tests, OSCE's are more susceptible to reliability errors because of the use of multiple cases and multiple examiners. In the pre-clinical phase of the medical curriculum of the University Medical Centre Utrecht, an OSCE is organised as a medical consult. We evaluated the radiology station. Method: Four questions were formulated: ·What is the internal consistency of the items of the radiology station? ·How do the scores on the radiology station compare with the scores on the test excluding radiology? ·How do different cases differ in scores? ·What are the differences in score between the examiners? We analysed the OSCE results of second year medical students in 2004. Results: Two hundred and sixty-five students were examined in the OSCE in 2004. Ninty-three Students were examined in the radiology station. Cronbach's alpha coefficient for the radiology station was 0.92. The average score for the radiology station was 3.8 (0.87). The average score for the test without radiology was 3.9 (0.32). The range of the average scores for the six different cases was 0.5 (3.6-4.1). The range of the average scores for the five examiners was 1.0 (3.3-4.3). Conclusion: The internal consistency of the items in the radiology station is good. The average score for the radiology station is similar to that of the other stations. The range of the scores between the different cases was relatively small. The range of the scores between the different examiners was clearly larger.

  6. [Multi-channel cochlear implants in patients with Mondini malformation].

    Science.gov (United States)

    Li, Yong-xin; Han, De-min; Zhao, Xiao-tian; Chen, Xue-qing; Kong, Ying; Zheng, Jun; Liu, Bo; Liu, Sha; Mo, Ling-yan; Zhang, Hua; Wang, Shuo

    2004-02-01

    To describe clinical experiences with multi-channel cochlear implantation in patients with Mondini malformation. Among 300 patients who received multi-channel cochlear implants from 1996 to 2002 in Beijing Tongren Hospital, 15 patients were diagnosed with Mondini malformation. A retrospective analysis was performed dealing with the surgical techniques, mapping and rehabilitations characteristics after surgery. 15 patients with normal cochlear structure are consider as control group. Gusher is found more common than the normal cochlear implantation, most of them are serious. The electrodes are inserted in the "cochleostomy" in full length of 13 Patients, 2 pairs of electrodes remains outside of "cochleostomy" in 2 patients. No serious complications occurred after implantation. All patients have auditory sensations. The impedance of the electrodes, the T level, C level and the hearing threshold are similar with the normal cochlear implantation group. The results have no significant difference in compare with normal cochlear group(P > 0.05). Multi-channel cochlear implantation could be performed safely in patients with Mondini malformation. The primary outcome for patients with Mondini malformation are similar to those with normal cochlear structure following the multi-channel cochlear implantation.

  7. [Cochlear implantation through the middle fossa approach].

    Science.gov (United States)

    Szyfter, W; Colletti, V; Pruszewicz, A; Kopeć, T; Szymiec, E; Kawczyński, M; Karlik, M

    2001-01-01

    The inner part of cochlear implant is inserted into inner ear during surgery through mastoid and middle ear. It is a classical method, used in the majority cochlear centers in the world. This is not a suitable method in case of chronic otitis media and middle ear malformation. In these cases Colletti proposed the middle fossa approach and cochlear implant insertion omitting middle ear structures. In patient with bilateral chronic otitis media underwent a few ears operations without obtaining dry postoperative cavity. Cochlear implantation through the middle fossa approach was performed in this patient. The bone fenster was cut, temporal lobe was bent and petrosus pyramid upper surface was exposed. When the superficial petrosal greater nerve, facial nerve and arcuate eminence were localised, the cochlear was open in the basal turn and electrode were inserted. The patient achieves good results in the postoperative speech rehabilitation. It confirmed Colletti tesis that deeper electrode insertion in the cochlear implantation through the middle fossa approach enable use of low and middle frequencies, which are very important in speech understanding.

  8. Technology as an Occasion for Structuring: Evidence from Observations of CT Scanners and the Social Order of Radiology Departments.

    Science.gov (United States)

    Barley, Stephen R.

    1986-01-01

    New technologies such as the CT scanner are challenging traditional role relations among radiology workers and may be altering the organizational and occupational structure of radiological work. This paper expands recent sociological thought by showing how identical CT scanners occasion similar structuring processes and created divergent forms of…

  9. Usage of structured reporting in radiological practice: results from an Italian online survey.

    Science.gov (United States)

    Faggioni, Lorenzo; Coppola, Francesca; Ferrari, Riccardo; Neri, Emanuele; Regge, Daniele

    2017-05-01

    To assess the opinion on structured reporting (SR) and its usage by radiologist members of the Italian Society of Medical Radiology (SIRM) via an online survey. All members received an email invitation to join the survey as an initiative by the SIRM Imaging Informatics Chapter. The survey included 10 questions about demographic information, definition of radiological SR, its usage in everyday practice, perceived advantages and disadvantages over conventional reporting and overall opinion about SR. 1159 SIRM members participated in the survey. 40.3 % of respondents gave a correct definition of radiological SR, but as many as 56 % of them never used it at work. Compared with conventional reporting, the most appreciated advantages of SR were higher reproducibility (70.5 %), better interaction with referring clinicians (58.3 %) and the option to link metadata (36.7 %). Risk of excessive simplification (59.8 %), template rigidity (56.1 %) and poor user compliance (42.1 %) were the most significant disadvantages. Overall, most respondents (87.0 %) were in favour of the adoption of radiological SR. Most radiologists were interested in radiological SR and in favour of its adoption. However, concerns about semantic, technical and professional issues limited its diffusion in real working life, encouraging efforts towards improved SR standardisation and engineering. • Despite radiologists' awareness, radiological SR is little used in working practice. • Perceived SR advantages are reproducibility, better clinico-radiological interaction and link to metadata. • Perceived SR disadvantages are excessive simplification, template rigidity and poor user compliance. • Improved standardisation and engineering may be helpful to boost SR diffusion.

  10. Usage of structured reporting in radiological practice: results from an Italian online survey

    Energy Technology Data Exchange (ETDEWEB)

    Faggioni, Lorenzo [University of Pisa, UO Radiodiagnostica 1, Department of Diagnostic and Interventional Radiology, Pisa (Italy); Coppola, Francesca [Sant' Orsola-Malpighi University Hospital, Malpighi Radiology Unit, Department of Diagnostic and Preventive Medicine, Bologna (Italy); Ferrari, Riccardo [Urgenza Emergenza, UOC Diagnostica per Immagini 1, Rome (Italy); Neri, Emanuele [Dipartimento di Ricerca Traslazionale, Universita di Pisa, Sezione Dipartimentale Radiodiagnostica 3, Azienda Ospedaliera Universitaria Pisana, Pisa (Italy); Regge, Daniele [Universita di Torino, Dipartimento di Scienze Chirurgiche, Candiolo Cancer Institute - FPO, IRCCS, Candiolo (Italy)

    2017-05-15

    To assess the opinion on structured reporting (SR) and its usage by radiologist members of the Italian Society of Medical Radiology (SIRM) via an online survey. All members received an email invitation to join the survey as an initiative by the SIRM Imaging Informatics Chapter. The survey included 10 questions about demographic information, definition of radiological SR, its usage in everyday practice, perceived advantages and disadvantages over conventional reporting and overall opinion about SR. 1159 SIRM members participated in the survey. 40.3 % of respondents gave a correct definition of radiological SR, but as many as 56 % of them never used it at work. Compared with conventional reporting, the most appreciated advantages of SR were higher reproducibility (70.5 %), better interaction with referring clinicians (58.3 %) and the option to link metadata (36.7 %). Risk of excessive simplification (59.8 %), template rigidity (56.1 %) and poor user compliance (42.1 %) were the most significant disadvantages. Overall, most respondents (87.0 %) were in favour of the adoption of radiological SR. Most radiologists were interested in radiological SR and in favour of its adoption. However, concerns about semantic, technical and professional issues limited its diffusion in real working life, encouraging efforts towards improved SR standardisation and engineering. (orig.)

  11. Trends in cochlear implants.

    Science.gov (United States)

    Zeng, Fan-Gang

    2004-01-01

    More than 60,000 people worldwide use cochlear implants as a means to restore functional hearing. Although individual performance variability is still high, an average implant user can talk on the phone in a quiet environment. Cochlear-implant research has also matured as a field, as evidenced by the exponential growth in both the patient population and scientific publication. The present report examines current issues related to audiologic, clinical, engineering, anatomic, and physiologic aspects of cochlear implants, focusing on their psychophysical, speech, music, and cognitive performance. This report also forecasts clinical and research trends related to presurgical evaluation, fitting protocols, signal processing, and postsurgical rehabilitation in cochlear implants. Finally, a future landscape in amplification is presented that requires a unique, yet complementary, contribution from hearing aids, middle ear implants, and cochlear implants to achieve a total solution to the entire spectrum of hearing loss treatment and management.

  12. Avaliação por imagem nos candidatos ao implante coclear: correlação radiológico-cirúrgica Evaluation by imaging methods of cochlear implant candidates: radiological and surgical correlation

    Directory of Open Access Journals (Sweden)

    Luiz Rodolpho Pena Lima Júnior

    2008-06-01

    Full Text Available No pré-operatório da cirurgia de Implante Coclear (IC o estudo por imagem adquire importância fundamental, proporcionando ao cirurgião segurança na indicação e realização da cirurgia. A avaliação ideal compreende a associação entre Tomografia Computadorizada (TC e Ressonância Nuclear Magnética (RNM. OBJETIVO: Avaliar a acurácia dos exames de imagem como preditores de possíveis complicações durante o ato cirúrgico. Desenho do Estudo: Corte transversal. MATERIAL E MÉTODOS: Foram avaliados por prontuários, 104 pacientes submetidos à cirurgia de IC de maio de 2003 a outubro de 2006. Estes passaram por uma seleção multidisciplinar pré-operatória, e radiológica por TC associada ou não à RNM. RESULTADOS: Excluiu-se 4 pacientes sem registro de exames radiológicos, resultando 100 pacientes. Estes foram divididos em dois grupos: grupo A (TC apresentou acurácia 69,69%, sensibilidade 36,36%; especificidade 86,36%; Valor Preditivo Positivo (VPP 57,14%; Valor Preditivo Negativo (VPN 73,07% e o B (TC e RNM acurácia 80,59%, sensibilidade 38,46%; especificidade 90,74%; VPP 50,0%; VPN 85,96%. CONCLUSÕES: A avaliação radiológica pré-operatória do IC mostrou-se importante, sendo capaz de identificar alterações anatômicas, evitando, ou ao menos, preparando o cirurgião para possíveis complicações. Esse estudo demonstrou que a avaliação associada com TC e RNM pôde ser considerada superior à TC isoladamente.Evaluation by imaging methods is critical in the preoperative care of cochlear implant (CI surgery, providing safety to surgeons when indicating and performing this procedure. The ideal imaging study consists of an association between Computed Tomography (CT and Magnetic Resonance Imaging (MRI. AIM: To investigate the accuracy of imaging studies as predictors of possible complications of surgery. Study Design: A cross-sectional investigation. MATERIAL AND METHOD: The medical records of 104 patients undergoing CI

  13. Microanatomy of the cochlear hook

    Science.gov (United States)

    Kwan, Changyow Claire; Tan, Xiaodong; Stock, Stuart R.; Soriano, Carmen; Xiao, Xianghui; Richter, Claus-Peter

    2017-09-01

    Communication among humans occurs through coding and decoding of acoustic information. The inner ear or cochlea acts as a frequency analyzer and divides the acoustic signal into small frequency bands, which are processed at different sites along the cochlea. The mechano-electrical conversion is accomplished by the soft tissue structures in the cochlea. While the anatomy for most of the cochlea has been well described, a detailed description of the very high frequency and vulnerable cochlear hook region is missing. To study the cochlear hook, mice cochleae were imaged with synchrotron radiation and high-resolution reconstructions have been made from the tomographic scans. This is the first detailed description of the bony and soft tissues of the hook region of the mammalian cochlea.

  14. Aspects of temporal bone anatomy and pathology in conjunction with cochlear implant surgery

    Energy Technology Data Exchange (ETDEWEB)

    Stjernholm, Christina [Karolinska Inst., Stockholm (Sweden). Soedersjukhuset

    2003-07-01

    Cochlear implantation is a treatment for patients with severe sensorineural hearing loss/deafness, who get no help from ordinary hearing aids. The cochlear implant is surgically placed under the skin near the ear and a very thin electrode array is introduced into the cochlea of the inner ear, where it stimulates the remaining nerve fibers. The operation is complicated; it is performed with the aid of a microscope, and involves drilling very close to vital vessels and important nerves. High resolution computed tomography (CT) of the temporal bone is a part of the preoperative evaluation preceding cochlear implantation. It is a method for visualizing the bony structures of the middle and inner ear - to diagnose pathology and to describe the anatomy. The first work concerns CT of the temporal bone and cochlear implant surgery in children with CHARGE association. This is a rare condition with multiple congenital abnormalities, sometimes lethal. Children with CHARGE have different combinations of disabilities, of which impairments of vision and hearing, as well as balance problems and facial palsy can lead to developmental delay. There have been few reports of radiological temporal bone changes and none of cochlear implant surgery for this group. The work includes a report of the findings on preoperative CT and at surgery, as well as postimplant results in two children. A review of the latest diagnostic criteria of CHARGE and the temporal bone changes found in international literature is also included. The conclusion was that certain combinations of temporal bone changes in CHARGE are, if not specific, at least extremely rare in other materials. CT can visualize these changes and be used as a diagnostic tool. This is important, since some of the associated disabilities are not so obvious from the start. Early treatment is vital for the child's development. This work also shows that cochlear implantation may help some of these often very isolated children to

  15. Aspects of temporal bone anatomy and pathology in conjunction with cochlear implant surgery

    International Nuclear Information System (INIS)

    Stjernholm, Christina

    2003-01-01

    Cochlear implantation is a treatment for patients with severe sensorineural hearing loss/deafness, who get no help from ordinary hearing aids. The cochlear implant is surgically placed under the skin near the ear and a very thin electrode array is introduced into the cochlea of the inner ear, where it stimulates the remaining nerve fibers. The operation is complicated; it is performed with the aid of a microscope, and involves drilling very close to vital vessels and important nerves. High resolution computed tomography (CT) of the temporal bone is a part of the preoperative evaluation preceding cochlear implantation. It is a method for visualizing the bony structures of the middle and inner ear - to diagnose pathology and to describe the anatomy. The first work concerns CT of the temporal bone and cochlear implant surgery in children with CHARGE association. This is a rare condition with multiple congenital abnormalities, sometimes lethal. Children with CHARGE have different combinations of disabilities, of which impairments of vision and hearing, as well as balance problems and facial palsy can lead to developmental delay. There have been few reports of radiological temporal bone changes and none of cochlear implant surgery for this group. The work includes a report of the findings on preoperative CT and at surgery, as well as postimplant results in two children. A review of the latest diagnostic criteria of CHARGE and the temporal bone changes found in international literature is also included. The conclusion was that certain combinations of temporal bone changes in CHARGE are, if not specific, at least extremely rare in other materials. CT can visualize these changes and be used as a diagnostic tool. This is important, since some of the associated disabilities are not so obvious from the start. Early treatment is vital for the child's development. This work also shows that cochlear implantation may help some of these often very isolated children to communicate

  16. Radiologic evaluation of structural abnormalities of the foot

    International Nuclear Information System (INIS)

    Adler, Y.T.; Tolliver, R.A.; Stern, D.S.; Fruin, M.E.

    1987-01-01

    This exhibit concentrates on often overlooked, unfamiliar biomechanical or structural abnormalities of the foot. Pericalcaneal pathology and its correlation with the presence of heel spurs is illustrated. In the tarsal area, coalitions, prehallux, and their relationships to abnormalities of the longitudinal arch are discussed. Distally, medial, dorsal and tailor's bunions are demonstrated. Pain and disability often precede obvious deformity, and a radiologist familiar with the early findings on x-ray studies may be the first member of the medical team to identify structural abnormalities. Diagnosis allows prompt institution of appropriate therapy, reducing the period of patient discomfort and disability

  17. Benefits and Risks of Cochlear Implants

    Science.gov (United States)

    ... and Medical Procedures Implants and Prosthetics Cochlear Implants Benefits and Risks of Cochlear Implants Share Tweet Linkedin ... the Use of Cochlear Implants What are the Benefits of Cochlear Implants? For people with implants: Hearing ...

  18. Evaluating two-dimensional skeletal structure parameters using radiological bone morphometric analysis

    International Nuclear Information System (INIS)

    Asa, Kensuke; Sakurai, Takashi; Kashima, Isamu; Kumasaka, Satsuki

    2005-01-01

    The objectives of this study was to investigate the reliability of two-dimensional (2D) skeletal structure parameters obtained using radiological bone morphometric analysis. The 2D skeletal parameters in the regions of interest (ROIs) were measured on computed radiography (CR) images of first phalanges from racehorses, using radiological bone morphometric analysis. Cancellous bone blocks were made from the phalanges in the same position as the ROI determined on CR images. Three-dimensional (3D) trabecular parameters were measured using micro-computed tomography (μCT). The correlations between the 2D skeletal parameters and 3D trabecular parameters were evaluated in relation to the measured bone strength. The following 2D skeletal structure parameters were correlated with bone strength (r=0.61-0.69): skeletal perimeter (Sk.Pm), skeletal number (Sk.N), skeletal separation (Sk.Sp), skeletal spacing (Sk.Spac), fractal dimension (FD), and skeletal pattern factor (SkPf). The 3D trabecular structure parameters were closely correlated with bone strength (r=0.74-0.86). The 2D skeletal parameters Sk.N, Sk.Pm, FD, SkPf, and Sk.Spac were correlated with the 3D trabecular parameters (r=0.61-0.70). The 2D skeletal parameters obtained using radiological bone morphometric analysis may be useful indicators of trabecular strength. (author)

  19. Trends in Cochlear Implants

    OpenAIRE

    Zeng, Fan-Gang

    2004-01-01

    More than 60,000 people worldwide use cochlear implants as a means to restore functional hearing. Although individual performance variability is still high, an average implant user can talk on the phone in a quiet environment. Cochlear-implant research has also matured as a field, as evidenced by the exponential growth in both the patient population and scientific publication. The present report examines current issues related to audiologic, clinical, engineering, anatomic, and physiologic as...

  20. Informatics in radiology: automated structured reporting of imaging findings using the AIM standard and XML.

    Science.gov (United States)

    Zimmerman, Stefan L; Kim, Woojin; Boonn, William W

    2011-01-01

    Quantitative and descriptive imaging data are a vital component of the radiology report and are frequently of paramount importance to the ordering physician. Unfortunately, current methods of recording these data in the report are both inefficient and error prone. In addition, the free-text, unstructured format of a radiology report makes aggregate analysis of data from multiple reports difficult or even impossible without manual intervention. A structured reporting work flow has been developed that allows quantitative data created at an advanced imaging workstation to be seamlessly integrated into the radiology report with minimal radiologist intervention. As an intermediary step between the workstation and the reporting software, quantitative and descriptive data are converted into an extensible markup language (XML) file in a standardized format specified by the Annotation and Image Markup (AIM) project of the National Institutes of Health Cancer Biomedical Informatics Grid. The AIM standard was created to allow image annotation data to be stored in a uniform machine-readable format. These XML files containing imaging data can also be stored on a local database for data mining and analysis. This structured work flow solution has the potential to improve radiologist efficiency, reduce errors, and facilitate storage of quantitative and descriptive imaging data for research. Copyright © RSNA, 2011.

  1. Technological and operational structure of the National Automatic Network for Environmental Radiological Monitoring (RENAMORA)

    International Nuclear Information System (INIS)

    Martinez G, E.; Lopez G, M.; Aguirre G, J.; Fabian O, R.; Hernandez A, Y.

    2015-09-01

    The Comision Nacional de Seguridad Nuclear y Salvaguardias (CNSNS) in Mexico is a decentralized body, under the Secretaria de Energia whose main mission is to ensure that activities involving nuclear and radioactive materials as well as ionizing radiation sources are carried out with maximum security, considering the current technological developments. In order to monitor the levels of environmental radiation to which the population is exposed, the CNSNS has established a series of radiological monitoring programs that allow characterize the environmental radiation levels in each zone or region in the country; to identify the occurrence of natural or artificial radiological events, such as nuclear tests and accidents in radioactive or nuclear facilities. The National Automatic Network for Environmental Radiological Monitoring (RENAMORA) project was initiated with the support of the IAEA through MEX9/049 project and its purpose is to have a network of instruments that automatically and in real time, transmit information of the gamma radiological environmental status of the national territory and changes occurring in it. This network provides data such as the speed of ambient dose equivalent, temperature and humidity in different regions of the country. The network is composed of 92 stations that are distributed throughout the national territory. The structure of the stations has evolved since its inception, now allowing detection tasks, data transmission and managing them remotely from the main server, which is located in the CNSNS, which is performed a statistical dose for each monitoring station. Each monitoring station is formed in its current structure by a probe detection of gamma radiation, a communication module and associated electronics, a mini Web server DataGATE, a cellular modem and an interface converter. (Author)

  2. Structure and content of radiology reports, a quantitative and qualitative study in eight medical centers

    International Nuclear Information System (INIS)

    Bosmans, Jan M.L.; Weyler, Joost J.; Parizel, Paul M.

    2009-01-01

    Rationale and objectives: In order to determine how the quality of the radiology report can be improved, the variation in content, form and length of the report needs to be examined. The purpose of the present study was to investigate and compare the length and structure of radiology reports (reports of abdominal CT examinations) in eight hospitals in the Netherlands and Flanders, the Dutch speaking part of Belgium. Materials and methods: Eight hundred reports - 100 from each collaborating center - were collected. After exclusion of the reports that did not fulfill the criteria for a standard CT examination of the abdomen, 525 were retained for further study. The structure of each report was analyzed and the constituting parts (technical information, description of the findings, conclusion, advice, remark, note) were determined. The character and word count of the report and its constituting parts were measured and the results were grouped according to the country (Netherlands vs. Belgium/Flanders), the qualification of the radiologist (staff members vs. residents.) and the nature of the hospital (university medical centers vs. community hospitals). Results: Statistically significant differences were found between the Netherlands and Flanders, and between staff members and residents. The authors also found a wide variety in the lay-out and the overall content of the radiology report. Conclusion: While most of the differences we found are probably rooted in local tradition, a standard model for the radiology report in centers sharing the same language may be a means to avoid interpretation mistakes by referring physicians, and to promote better care.

  3. The Role of MRI in Diagnosing Neurovascular Compression of the Cochlear Nerve Resulting in Typewriter Tinnitus.

    Science.gov (United States)

    Bae, Y J; Jeon, Y J; Choi, B S; Koo, J-W; Song, J-J

    2017-06-01

    Typewriter tinnitus, a symptom characterized by paroxysmal attacks of staccato sounds, has been thought to be caused by neurovascular compression of the cochlear nerve, but the correlation between radiologic evidence of neurovascular compression of the cochlear nerve and symptom presentation has not been thoroughly investigated. The purpose of this study was to examine whether radiologic evidence of neurovascular compression of the cochlear nerve is pathognomonic in typewriter tinnitus. Fifteen carbamazepine-responding patients with typewriter tinnitus and 8 control subjects were evaluated with a 3D T2-weighted volume isotropic turbo spin-echo acquisition sequence. Groups 1 (16 symptomatic sides), 2 (14 asymptomatic sides), and 3 (16 control sides) were compared with regard to the anatomic relation between the vascular loop and the internal auditory canal and the presence of neurovascular compression of the cochlear nerve with/without angulation/indentation. The anatomic location of the vascular loop was not significantly different among the 3 groups (all, P > .05). Meanwhile, neurovascular compression of the cochlear nerve on MR imaging was significantly higher in group 1 than in group 3 ( P = .032). However, considerable false-positive (no symptoms with neurovascular compression of the cochlear nerve on MR imaging) and false-negative (typewriter tinnitus without demonstrable neurovascular compression of the cochlear nerve) findings were also observed. Neurovascular compression of the cochlear nerve was more frequently detected on the symptomatic side of patients with typewriter tinnitus compared with the asymptomatic side of these patients or on both sides of control subjects on MR imaging. However, considering false-positive and false-negative findings, meticulous history-taking and the response to the initial carbamazepine trial should be regarded as more reliable diagnostic clues than radiologic evidence of neurovascular compression of the cochlear nerve.

  4. Rehabilitation of deaf persons with cochlear implants

    International Nuclear Information System (INIS)

    Gstoettner, W.; Hamzavi, J.; Czerny, C.

    1997-01-01

    In the last decade, the rehabilitation of postlingually deaf adults and prelingually deaf children with cochlear implants has been established as a treatment of deafness. The technological development of the implant devices and improvement of the surgical technique have led to a considerable increase of hearing performance during the last years. The postlingually deaf adults are able to use the telephone and may be integrated in their original job. Prelingually deaf children can even visit normal schools after cochlear implantation and hearing rehabilitation training. In order to preoperatively establish the state of the cochlear, radiological diagnosis of the temporal bone is necessary. High resolution computerized tomography imaging of the temporal bone with coronar and axial 1 mm slices and MRI with thin slice technique (three dimensional, T2 weighted turbo-spinecho sequence with 0.7 mm slices) have proved to be valuable according to our experience. Furthermore a postoperative synoptical X-ray, in a modified Chausse III projection, offers good information about the position of the implant and insertion of the stimulating electrode into the cochlea. (orig.) [de

  5. Pre-, intra- and post-operative imaging of cochlear implants

    Energy Technology Data Exchange (ETDEWEB)

    Vogl, T.J.; Naguib, N.N.N.; Burck, I. [University Hospital Frankfurt (Germany). Inst. of Diagnostic and Interventional Radiology; Tawfik, A. [Mansoura Univ. (Egypt). Dept. of Diagnostic and Interventional Radiology; Emam, A. [University Hospital Alexandria (Egypt). Dept. of Diagnostic and Interventional Radiology; Nour-Eldin, A. [University Hospital Cairo (Egypt). Dept. of Radiology; Stoever, T. [University Hospital of Frankfurt (Germany). Dept. of Otolaryngology

    2015-11-15

    The purpose of this review is to present essential imaging aspects in patients who are candidates for a possible cochlear implant as well as in postsurgical follow-up. Imaging plays a major role in providing information on preinterventional topography, variations and possible infections. Preoperative imaging using DVT, CT, MRI or CT and MRI together is essential for candidate selection, planning of surgical approach and exclusion of contraindications like the complete absence of the cochlea or cochlear nerve, or infection. Relative contraindications are variations of the cochlea and vestibulum. Intraoperative imaging can be performed by fluoroscopy, mobile radiography or DVT. Postoperative imaging is regularly performed by conventional X-ray, DVT, or CT. In summary, radiological imaging has its essential role in the pre- and post-interventional period for patients who are candidates for cochlear implants.

  6. Outcomes and special considerations of cochlear implantation in waardenburg syndrome.

    Science.gov (United States)

    Kontorinis, Georgios; Lenarz, Thomas; Giourgas, Alexandros; Durisin, Martin; Lesinski-Schiedat, Anke

    2011-08-01

    The objective of this study was a state-of-the-art analysis of cochlear implantation in patients with Waardenburg syndrome (WS). Twenty-five patients with WS treated with cochlear implants in our department from 1990 to 2010. The 25 patients with WS underwent 35 cochlear implantations. Hearing outcome was evaluated using HSM sentence test in 65 dB in quiet, Freiburg Monosyllabic Test, and categories of auditory performance for children and compared with that of a control group. Anatomic abnormalities of the inner ear were examined using magnetic resonance imaging and computed tomography of the temporal bones. The mean follow-up time was 8.3 years (range, 0.3-18.3 yr). The majority achieved favorable postimplantation performance with mean HSM scores of 75.3% (range, 22.6%-99%) and Freiburg Monosyllabic Test scores of 67.8% (range, 14%-95%). However, in 4 cases, the results were less satisfactory. The comparison with the control group did not reveal any statistical significance (p = 0.56). In 6 patients (24%), behavioral disorders caused temporary difficulties during the rehabilitation procedure. Except of isolated large vestibule in 1 patient, the radiological assessment of the 50 temporal bones did not reveal any temporal bone abnormalities. Most patients with WS performed well with cochlear implants. However, WS is related to behavioral disorders that may cause temporary rehabilitation difficulties. Finally, temporal bone malformations that could affect cochlear implantation are notcharacteristic of WS.

  7. Effect of cochlear nerve electrocautery on the adult cochlear nucleus.

    Science.gov (United States)

    Iseli, Claire E; Merwin, William H; Klatt-Cromwell, Cristine; Hutson, Kendall A; Ewend, Matthew G; Adunka, Oliver F; Fitzpatrick, Douglas C; Buchman, Craig A

    2015-04-01

    Electrocauterization and subsequent transection of the cochlear nerve induce greater injury to the cochlear nucleus than sharp transection alone. Some studies show that neurofibromatosis Type 2 (NF2) patients fit with auditory brainstem implants (ABIs) fail to achieve speech perception abilities similar to ABI recipients without NF2. Reasons for these differences remain speculative. One hypothesis posits poorer performance to surgically induced trauma to the cochlear nucleus from electrocautery. Sustained electrosurgical depolarization of the cochlear nerve may cause excitotoxic-induced postsynaptic nuclear injury. Equally plausible is that cautery in the vicinity of the cochlear nucleus induces necrosis. The cochlear nerve was transected in anesthetized adult gerbils sharply with or without bipolar electrocautery at varying intensities. Gerbils were perfused at 1, 3, 5, and 7 days postoperatively; their brainstem and cochleas were embedded in paraffin and sectioned at 10 μm. Alternate sections were stained with flourescent markers for neuronal injury or Nissl substance. In additional experiments, anterograde tracers were applied directly to a sectioned eighth nerve to verify that fluorescent-labeled profiles seen were terminating auditory nerve fibers. Cochlear nerve injury was observed from 72 hours postoperatively and was identical across cases regardless of surgical technique. Postsynaptic cochlear nucleus injury was not seen after distal transection of the nerve. By contrast, proximal transection was associated with trauma to the cochlear nucleus. Distal application of bipolar electrocautery seems safe for the cochlear nucleus. Application near the root entry zone must be used cautiously because this may compromise nuclear viability needed to support ABI stimulation.

  8. STEREOLOGICAL ANALYSIS OF THE COCHLEAR NUCLEI OF MONKEY (MACACA FASCICULARIS AFTER DEAFFERENTATION

    Directory of Open Access Journals (Sweden)

    Ana M Insausti

    2011-05-01

    Full Text Available The cochlear nuclei (CN in the brainstem receive the input signals from the inner ear through the cochlear nerve, and transmit these signals to higher auditory centres. A variety of lesions of the cochlear nerve cause deafness. As reported in the literature, artificial removal of auditive input, or 'deafferentation', induces structural alterations in the CN. The purpose of this study was to estimate a number of relevant stereological parameters of the CN in control and deafferented Macaca fascicularis monkeys.

  9. Cochlear implant: the family's perspective.

    Science.gov (United States)

    Vieira, Sheila de Souza; Dupas, Giselle; Chiari, Brasilia Maria

    2018-07-01

    To understand the family's experience of a child who uses a cochlear implant (CI). Specifically, to identify the difficulties, changes, and feelings entailed by deafness and the use of the CI; the coping strategies; and to understand the role of the family for the child with a CI. Qualitative research, using Symbolic Interactionism and Straussian Grounded Theory as the theoretical and methodological frameworks, respectively. Data collection instrument: semi-structured interview. A total of 9 families (32 individuals) participated in the study. The children's ages ranged from 6 to 11 years old (mean = 8.9 years old). Their experience is described in the following categories: Having to fight for results, Coping with difficult situations, Recognizing that you are not alone, Learning to overcome, and Having one's life restored by the implant. Cochlear implantation changes the direction of the child and the family's life by restoring the child's opportunity to hear and to obtain good results in her personal, social, and academic development. Even after implantation, the child continues to experience difficulties and requires the family's mobilization in order to be successful. The family is the principal actor in the process of the child's rehabilitation.

  10. Auditory Mechanics of the Tectorial Membrane and the Cochlear Spiral

    Science.gov (United States)

    Gavara, Núria; Manoussaki, Daphne; Chadwick, Richard S.

    2012-01-01

    Purpose of review This review is timely and relevant since new experimental and theoretical findings suggest that cochlear mechanics from the nanoscale to the macroscale are affected by mechanical properties of the tectorial membrane and the spiral shape. Recent findings Main tectorial membrane themes covered are i) composition and morphology, ii) nanoscale mechanical interactions with the outer hair cell bundle, iii) macroscale longitudinal coupling, iv) fluid interaction with inner hair cell bundles, v) macroscale dynamics and waves. Main cochlear spiral themes are macroscale low-frequency energy focusing and microscale organ of Corti shear gain. Implications Findings from new experimental and theoretical models reveal exquisite sensitivity of cochlear mechanical performance to tectorial membrane structural organization, mechanics, and its positioning with respect to hair bundles. The cochlear spiral geometry is a major determinant of low frequency hearing. Suggestions are made for future research directions. PMID:21785353

  11. Exemplary design of a DICOM structured report template for CBIR integration into radiological routine

    Science.gov (United States)

    Welter, Petra; Deserno, Thomas M.; Gülpers, Ralph; Wein, Berthold B.; Grouls, Christoph; Günther, Rolf W.

    2010-03-01

    The large and continuously growing amount of medical image data demands access methods with regards to content rather than simple text-based queries. The potential benefits of content-based image retrieval (CBIR) systems for computer-aided diagnosis (CAD) are evident and have been approved. Still, CBIR is not a well-established part of daily routine of radiologists. We have already presented a concept of CBIR integration for the radiology workflow in accordance with the Integrating the Healthcare Enterprise (IHE) framework. The retrieval result is composed as a Digital Imaging and Communication in Medicine (DICOM) Structured Reporting (SR) document. The use of DICOM SR provides interchange with PACS archive and image viewer. It offers the possibility of further data mining and automatic interpretation of CBIR results. However, existing standard templates do not address the domain of CBIR. We present a design of a SR template customized for CBIR. Our approach is based on the DICOM standard templates and makes use of the mammography and chest CAD SR templates. Reuse of approved SR sub-trees promises a reliable design which is further adopted to the CBIR domain. We analyze the special CBIR requirements and integrate the new concept of similar images into our template. Our approach also includes the new concept of a set of selected images for defining the processed images for CBIR. A commonly accepted pre-defined template for the presentation and exchange of results in a standardized format promotes the widespread application of CBIR in radiological routine.

  12. Visualization of spiral ganglion neurites within the scala tympani with a cochlear implant in situ.

    Science.gov (United States)

    Chikar, Jennifer A; Batts, Shelley A; Pfingst, Bryan E; Raphael, Yehoash

    2009-05-15

    Current cochlear histology methods do not allow in situ processing of cochlear implants. The metal components of the implant preclude standard embedding and mid-modiolar sectioning, and whole mounts do not have the spatial resolution needed to view the implant within the scala tympani. One focus of recent auditory research is the regeneration of structures within the cochlea, particularly the ganglion cells and their processes, and there are multiple potential benefits to cochlear implant users from this work. To facilitate experimental investigations of auditory nerve regeneration performed in conjunction with cochlear implantation, it is critical to visualize the cochlear tissue and the implant together to determine if the nerve has made contact with the implant. This paper presents a novel histological technique that enables simultaneous visualization of the in situ cochlear implant and neurofilament-labeled nerve processes within the scala tympani, and the spatial relationship between them.

  13. Cochlear implantation in Mondini dysplasia.

    Science.gov (United States)

    Daneshi, Ahmad; Hassanzadeh, Saeid; Abasalipour, Parvaneh; Emamdjomeh, Hessamaddin; Farhadi, Mohammad

    2003-01-01

    The use of cochlear implantation to treat patients with inner ear malformations such as Mondini dysplasia has been increasingly successful. Until now, conventional hearing aids in these patients have not performed well. Consequently, the hearing problem for patients with this condition has been somewhat improved with the use of cochlear implants. Various results of cochlear implantation have been reported in these patients so far. This is a report of 5 patients with Mondini malformation who have undergone cochlear implant surgery. Copyright 2003 S. Karger AG, Basel

  14. Reflective type objective based spectral-domain phase-sensitive optical coherence tomography for high-sensitive structural and functional imaging of cochlear microstructures through intact bone of an excised guinea pig cochlea

    Science.gov (United States)

    Subhash, Hrebesh M.; Wang, Ruikang K.; Chen, Fangyi; Nuttall, Alfred L.

    2013-03-01

    Most of the optical coherence tomographic (OCT) systems for high resolution imaging of biological specimens are based on refractive type microscope objectives, which are optimized for specific wave length of the optical source. In this study, we present the feasibility of using commercially available reflective type objective for high sensitive and high resolution structural and functional imaging of cochlear microstructures of an excised guinea pig through intact temporal bone. Unlike conventional refractive type microscopic objective, reflective objective are free from chromatic aberrations due to their all-reflecting nature and can support a broadband of spectrum with very high light collection efficiency.

  15. Efter cochlear implant

    DEFF Research Database (Denmark)

    Højen, Anders

    Dit barn har netop fået et cochlear implant. Hvad nu? Skal barnet fokusere udelukkende på at lære talt sprog, eller skal det også lære/fortsætte med tegnsprog eller støttetegn? Det er et vanskeligt spørgsmål, og før valget foretages, er det vigtigt at vurdere hvilke konsekvenser valget har, dels...... for den sproglige udvikling isoleret set, og dels for barnets udvikling ud fra en helhedsbetragtning. Dette indlæg fokuserer på, hvilke forventninger man kan have til cochlear implant-brugeres sproglige udvikling med talt sprog alene, hhv. med to sprog (tale og tegn). Disse forventninger er baseret på...

  16. Modelling Cochlear Mechanics

    Directory of Open Access Journals (Sweden)

    Guangjian Ni

    2014-01-01

    Full Text Available The cochlea plays a crucial role in mammal hearing. The basic function of the cochlea is to map sounds of different frequencies onto corresponding characteristic positions on the basilar membrane (BM. Sounds enter the fluid-filled cochlea and cause deflection of the BM due to pressure differences between the cochlear fluid chambers. These deflections travel along the cochlea, increasing in amplitude, until a frequency-dependent characteristic position and then decay away rapidly. The hair cells can detect these deflections and encode them as neural signals. Modelling the mechanics of the cochlea is of help in interpreting experimental observations and also can provide predictions of the results of experiments that cannot currently be performed due to technical limitations. This paper focuses on reviewing the numerical modelling of the mechanical and electrical processes in the cochlea, which include fluid coupling, micromechanics, the cochlear amplifier, nonlinearity, and electrical coupling.

  17. Cochlear implantation in patients with bilateral cochlear trauma.

    Science.gov (United States)

    Serin, Gediz Murat; Derinsu, Ufuk; Sari, Murat; Gergin, Ozgül; Ciprut, Ayça; Akdaş, Ferda; Batman, Cağlar

    2010-01-01

    Temporal bone fracture, which involves the otic capsule, can lead to complete loss of auditory and vestibular functions, whereas the patients without fractures may experience profound sensorineural hearing loss due to cochlear concussion. Cochlear implant is indicated in profound sensorineural hearing loss due to cochlear trauma but who still have an intact auditory nerve. This is a retrospective review study. We report 5 cases of postlingually deafened patients caused by cochlear trauma, who underwent cochlear implantation. Preoperative and postoperative hearing performance will be presented. These patients are cochlear implanted after the cochlear trauma in our department between 2001 and 2006. All patients performed very well with their implants, obtained open-set speech understanding. They all became good telephone users after implantation. Their performance in speech understanding was comparable to standard postlingual adult patients implanted. Cochlear implantation is an effective aural rehabilitation in profound sensorineural hearing loss caused by temporal bone trauma. Preoperative temporal bone computed tomography, magnetic resonance imaging, and promontorium stimulation testing are necessary to make decision for the surgery and to determine the side to be implanted. Surgery could be challenging and complicated because of anatomical irregularity. Moreover, fibrosis and partial or total ossification within the cochlea must be expected. Copyright 2010. Published by Elsevier Inc.

  18. Cochlear implantation in Waardenburg syndrome: The Indian scenario.

    Science.gov (United States)

    Deka, Ramesh Chandra; Sikka, Kapil; Chaturvedy, Gaurav; Singh, Chirom Amit; Venkat Karthikeyan, C; Kumar, Rakesh; Agarwal, Shivani

    2010-10-01

    Children with Waardenburg syndrome (WS) exhibiting normal inner ear anatomy, like those included in our cohort, derive significant benefit from cochlear implantation and results are comparable to those reported for the general population of implanted children. The patient population of WS accounts for approximately 2% of congenitally deaf children. The purpose of this retrospective case review was to describe the outcomes for those children with WS who have undergone cochlear implantation. On retrospective chart review, there were four cases with WS who underwent cochlear implantation. These cases were assessed for age at implantation, clinical and radiological features, operative and perioperative course, and performance outcomes. Auditory perception and speech production ability were evaluated using categories of auditory performance (CAP), meaningful auditory integration scales (MAIS), and speech intelligibility rating (SIR) during the follow-up period. In this group of children with WS, with a minimum follow-up of 12 months, the CAP score ranged from 3 to 5, MAIS from 25 to 30, and SIR was 3. These scores are comparable with those of other cochlear implantees.

  19. Cochlear pathology: CT and MRI findings

    International Nuclear Information System (INIS)

    Martinez, Manuel; Bruno, Claudio; Martin, Eduardo; Canale, Nancy; De Luca, Laura; Spina, Juan C. h

    2002-01-01

    The authors present a retrospective analysis of 50 patients with perceptive hearing loss. The neuro physiological work-up (evoked potentials, audiometric tests and otoemissions) identified the cochlea as the site of origin of the hearing loss. The imaging studies (high resolution CT and MR, including 3D volumes) showed petrous bone trauma (n=5) infections (bacterial or viral origin) (n=12) otosclerosis (n=8), Paget disease (n=3), and labyrinthine neurinomas (n=2). The other 20 cases showed development-linked disorders (Mitchel's, Mondini, Scheibe, Alexander, and hypoplasia of the cochlear canal). Imaging with CT and MR can identify in detail the structural abnormality affecting the cochlea and occasionally the immediate peri-cochlear region (otic capsule); the affected portion of the cochlea may thus be determined. (author)

  20. A correlational method to concurrently measure envelope and temporal fine structure weights: effects of age, cochlear pathology, and spectral shaping.

    Science.gov (United States)

    Fogerty, Daniel; Humes, Larry E

    2012-09-01

    The speech signal may be divided into spectral frequency-bands, each band containing temporal properties of the envelope and fine structure. This study measured the perceptual weights for the envelope and fine structure in each of three frequency bands for sentence materials in young normal-hearing listeners, older normal-hearing listeners, aided older hearing-impaired listeners, and spectrally matched young normal-hearing listeners. The availability of each acoustic property was independently varied through noisy signal extraction. Thus, the full speech stimulus was presented with noise used to mask six different auditory channels. Perceptual weights were determined by correlating a listener's performance with the signal-to-noise ratio of each acoustic property on a trial-by-trial basis. Results demonstrate that temporal fine structure perceptual weights remain stable across the four listener groups. However, a different weighting typography was observed across the listener groups for envelope cues. Results suggest that spectral shaping used to preserve the audibility of the speech stimulus may alter the allocation of perceptual resources. The relative perceptual weighting of envelope cues may also change with age. Concurrent testing of sentences repeated once on a previous day demonstrated that weighting strategies for all listener groups can change, suggesting an initial stabilization period or susceptibility to auditory training.

  1. Cochlear pathology in chronic suppurative otitis media.

    Science.gov (United States)

    Walby, A P; Barrera, A; Schuknecht, H F

    1983-01-01

    Chronic suppurative otitis media (COM) is reported to cause elevation of bone-conduction thresholds either by damage to cochlear sensorineural structures or by alteration in the mechanics of sound transmission in the ear. A retrospective study was made of the medical records of 87 patients with unilateral uncomplicated COM to document that abnormality in bone conduction does exist. In a separate study the cochlear pathology in 12 pairs of temporal bones with unilateral COM was studied by light microscopy. Infected ears showed higher than normal mean bone-conduction thresholds by amounts ranging from 1 dB at 500 Hz to 9.5 dB at 4,000 Hz. The temporal bones showed no greater loss of specialized sensorineural structures in infected ears than in normal control ears. Because there is no evidence that COM caused destruction of hair cells or cochlear neurons, alteration in the mechanics of sound transmission becomes a more plausible explanation for the hearing losses.

  2. Radiological diagnostics in hyperparathyroidism

    International Nuclear Information System (INIS)

    Moedder, U.; Kuhn, F.P.; Gruetzner, G.

    1991-01-01

    The most important radiologically detectable effects of the primary and secondary hyperparathyroidism of the skeletal system and the periarticular soft tissue structures are presented. In the following sensitivity and specificity of radiological imaging - sonography, scintigraphy, computed tomography, magnetic resonance imaging, arteriography and selective venous sampling - in the preoperative diagnostic of the parathyroid adenomas are discussed. Therefore, radiological imaging can be omitted before primary surgery. It was only in secondary surgery that radiological process proved useful and a guide during surgical intervention. (orig.) [de

  3. Cochlear implant magnet retrofit.

    Science.gov (United States)

    Cohen, N L; Breda, S D; Hoffman, R A

    1988-06-01

    An implantable magnet is now available for patients who have received the standard Nucleus 22-channel cochlear implant and who are not able to wear the headband satisfactorily. This magnet is attached in piggy-back fashion to the previously implanted receiver/stimulator by means of a brief operation under local anesthesia. Two patients have received this magnet retrofit, and are now wearing the headset with greater comfort and satisfaction. It is felt that the availability of this magnet will increase patient compliance in regard to hours of implant usage.

  4. Cochlear implants in Waardenburg syndrome.

    Science.gov (United States)

    Cullen, Robert D; Zdanski, Carlton; Roush, Patricia; Brown, Carolyn; Teagle, Holly; Pillsbury, Harold C; Buchman, Craig

    2006-07-01

    Waardenburg syndrome is an autosomal-dominant syndrome characterized by dystopia canthorum, hyperplasia of the eyebrows, heterochromia irides, a white forelock, and sensorineural hearing loss in 20% to 55% of patients. This patient population accounts for approximately 2% of congenitally deaf children. The purpose of this retrospective case review was to describe the outcomes for those children with Waardenburg syndrome who have undergone cochlear implantation. Pediatric cochlear implant recipients with documented evidence of Waardenburg syndrome underwent retrospective case review. All patients received their cochlear implants at the study institution followed by outpatient auditory habilitation. Charts were reviewed for etiology and duration of deafness, age at time of cochlear implantation, perioperative complications, duration of use, and performance outcomes. Results of standard tests batteries for speech perception and production administered as a part of the patients' auditory habilitation were reviewed. Seven patients with Waardenburg syndrome and cochlear implants were identified. The average age at implantation was 37 months (range, 18-64 months) and the average duration of use was 69 months (range, 12-143 months). All of these patients are active users of their devices and perform very well after implantation. There were no major complications in this small group of patients. Children with congenital sensorineural hearing loss without other comorbidities (e.g., developmental delay, inner ear malformations) perform well when they receive cochlear implantation and auditory habilitation. Patients with Waardenburg syndrome can be expected to have above-average performance after cochlear implantation.

  5. COCHLEAR IMPLANTATION PREVALENCE IN ELDERLY

    Directory of Open Access Journals (Sweden)

    A. V. Starokha

    2014-01-01

    Full Text Available Current paper describes an experience of cochlear implantation in elderly. Cochlear implantation has become a widely accepted intervention in the treatment of individuals with severe-to-profound sensorineural hearing loss. Cochlear implants are now accepted as a standard of care to optimize hearing and subsequent speech development in children and adults with deafness. But cochlear implantation affects not only hearing abilities, speech perception and speech production; it also has an outstanding impact on the social life, activities and self-esteem of each patient. The aim of this study was to evaluate the cochlear implantation efficacy in elderly with severe to profound sensorineural hearing loss. There were 5 patients under our observation. Surgery was performed according to traditional posterior tympanotomy and cochleostomy for cochlear implant electrode insertion for all observed patients. The study was conducted in two stages: before speech processor’s activation and 3 months later. Pure tone free field audiometry was performed to each patient to assess the efficiency of cochlear implantation in dynamics. The aim of the study was also to evaluate quality of life in elderly with severe to profound sensorineural hearing loss after unilateral cochlear implantation. Each patient underwent questioning with 36 Item Short Form Health Survey (SF-36. SF-36 is a set of generic, coherent, and easily administered quality-of-life measures. The SF-36 consists of eight scaled scores, which are the weighted sums of the questions in their section. Each scale is directly transformed into a 0-100 scale on the assumption that each question carries equal weight. The eight sections are: physical functioning; physical role functioning; emotional role functioning; vitality; emotional well-being; social role functioning; bodily pain; general health perceptions. Our results demonstrate that cochlear implantation in elderly consistently improved quality of life

  6. Labyrinthectomy with cochlear implantation.

    Science.gov (United States)

    Zwolan, T A; Shepard, N T; Niparko, J K

    1993-05-01

    Numerous reports indicate that the cochlea remains responsive to electrical stimulation following labyrinthectomy. We report a case of a 47-year-old woman with a severe to profound sensorineural hearing loss from birth, who developed episodic vertigo with symptoms suggestive of delayed onset endolymphatic hydrops. Following 8 months of failed medical and vestibular rehabilitation management, a right-sided labyrinthectomy combined with cochlear implantation was performed without complication. Postoperatively the patient was free of vertigo. Attempts to activate the patient's device between 4 to 12 weeks after surgery were unsuccessful as stimulation of the electrodes resulted in discomfort. However, all 20 electrodes elicited comfortable hearing sensations 16 weeks postsurgery. One year after the successful activation, the patient demonstrated improved sound awareness and speech recognition with the implant when compared with preoperative performance with a hearing aid. This case study suggests that electrical detection thresholds with prosthetic stimulation may be unstable in the recently labyrinthectomized ear but supports and extends prior observations of preserved cochlear responsiveness after labyrinthectomy.

  7. Radiology today

    International Nuclear Information System (INIS)

    Donner, M.W.; Heuck, F.H.W.

    1981-01-01

    The book encompasses the proceedings of a postgraduate course held in Salzburg in June 1980. 230 radiologists from 17 countries discussed here the important and practical advances of diagnostic radiology, nuclear medicine and ultrasound as they contribute to gastrointestinal, urologic, skeletal, cardiovascular, pediatric, and neuroradiology. The book contains 55 single contributions of different authors to the following main themes: Cardiovascular, Radiology, pulmonary radiology, gastrointestinal radiology, urinary tract radiology, skeletal radiology, mammography, lymphography, ultrasound, ENT radiology, and neuroradiology. (orig./MG)

  8. Exploring the experiences of teenagers with cochlear implants.

    Science.gov (United States)

    Watson, Victoria; Verschuur, Carl; Lathlean, Judith

    2016-11-01

    Teenage cochlear implant users' perceptions of deafness, surgery, fitting of the device and life as a cochlear implant wearer were explored in order to gain a more comprehensive understanding of teenagers' experiences of living with the device. Semi-structured in-depth interviews were undertaken and analysed using thematic analysis. Ten teenagers aged 14-16 years with at least one cochlear implant were interviewed. Seven teenagers experienced great pre-operative anxiety and two reported significant post-operative pain. Four of the teenagers described a mismatch between their expectations and the disappointing reality of adjusting to the device. However, all the teenagers reported an enhanced sense of well-being as a result of being able to interact more easily with their world around them. The teenagers differed in the extent to which they identified with the hearing and deaf world. Despite the early challenges, over time the teenagers experienced many functional and psychosocial benefits. Most felt their lives were now easier as a result of the cochlear implant(s). They described complex, flexible identities. By giving prominence to the teenagers' voices this study has added new knowledge concerning their experience of surgery. The findings also more fully revealed the challenges of adjusting to the device and the impact of having a cochlear implant on the teenagers' identities. Clinical recommendations are made to address the gaps in service highlighted by these findings.

  9. Cochlear implants and medical tourism.

    Science.gov (United States)

    McKinnon, Brian J; Bhatt, Nishant

    2010-09-01

    To compare the costs of medical tourism in cochlear implant surgery performed in India as compared to the United States. In addition, the cost savings of obtaining cochlear implant surgery in India were compare d to those of other surgical interventions obtained as a medical tourist. Searches were conducted on Medline and Google using the search terms: 'medical tourism', 'medical offshoring', 'medical outsourcing', 'cochlear implants' and 'cochlear implantation'. The information regarding cost of medical treatment was obtained from personal communication with individuals familiar with India's cochlear implantation medical tourism industry. The range of cost depended on length of stay as well as the device chosen. Generally the cost, inclusive of travel, surgery and device, was in the range of $21,000-30,000, as compared to a cost range of $40,000-$60,000 in the US. With the escalating cost of healthcare in the United States, it is not surprising that some patients would seek to obtain surgical care overseas at a fraction of the cost. Participants in medical tourism often have financial resources, but lack health insurance coverage. While cardiovascular and orthopedic surgery performed outside the United States in India at centers that cater to medical tourists are often performed at one-quarter to one-third of the cost that would have been paid in the United States, the cost differential for cochlear implants is not nearly as favorable.

  10. [Applied anatomy of scala tympani inlet related to cochlear implantation].

    Science.gov (United States)

    Zou, Tuanming; Guo, Menghe; Zhang, Hongzheng; Shu, Fan; Xie, Nanping

    2012-06-01

    To investigate the related parameters of the temporal bone structure for determining the position of implanting electrode into the scala tympani in cochlear implantation surgery through the facial recess and epitympanum approach. In a surgical simulation experiment, 20 human temporal bones were studied and measured to determine the related parameters of the temporal bone structure. The distance 5.91∓0.29 mm between the short process of the incus and the round window niche, 2.11∓0.18 mm between the stapes and the round window niche, 6.70∓0.19 mm between the facial nerve in the perpendicular paragraph and the round window niche, 2.22∓0.21 mm from the pyramidal eminence to the round window, and 2.16∓0.14 mm between the stapes and the round window. The minimal distance between the implanting electrode and the vestibular window was 2.12∓0.19 mm. The distance between the cochleariform process and the round window niche was 3.79∓0.17 mm. The position of the cochlear electrode array insertion into the second cochlear turn was 2.25∓0.13 mm under the stapes. The location of the cochlear electrode array insertion into the second cochlear turn was 2.28∓0.20 mm inferior to the pyramidal eminence. These parameters provide a reference value to determine the different positions of cochlear electrode array insertion into the scale tympani in different patients.

  11. Racemic alkaloids from the fungus Ganoderma cochlear.

    Science.gov (United States)

    Wang, Xin-Long; Dou, Man; Luo, Qi; Cheng, Li-Zhi; Yan, Yong-Ming; Li, Rong-Tao; Cheng, Yong-Xian

    2017-01-01

    Seven pairs of new alkaloid enantiomers, ganocochlearines C-I (1, 3-8), and three pairs of known alkaloids were isolated from the fruiting bodies of Ganoderma cochlear. The chemical structures of new compounds were elucidated on the basis of 1D and 2D NMR data. The absolute configurations of compounds 1, 3-10 were assigned by ECD calculations. Biological activities of these isolates against renal fibrosis were accessed in rat normal or diseased renal interstitial fibroblast cells. Importantly, the plausible biosynthetic pathway for this class of alkaloids was originally proposed. Copyright © 2016 Elsevier B.V. All rights reserved.

  12. Cochlear implantation in a bilateral Mondini dysplasia.

    Science.gov (United States)

    Turrini, M; Orzan, E; Gabana, M; Genovese, E; Arslan, E; Fisch, U

    1997-01-01

    We report the speech perception progress and programming procedures of a case of congenital profound deafness and bilateral Mondini dysplasia implanted with a Nucleus 20 + 2 cochlear implant at the age of six. Unclear relations between electrodes array and cochlear partition made implant programming difficult and non-standard procedures were set. Cochlear implantation may give excellent rehabilitative results also in cochleae with malformation.

  13. Radiological evaluation of dysphagia

    Energy Technology Data Exchange (ETDEWEB)

    Ott, D.J.; Gelfand, D.W.; Wu, W.C.; Chen, Y.M.

    1986-11-21

    Dysphagia is a common complaint in patients presenting for radiological or endoscopic examination of the esophagus and is usually due to functional or structural abnormalities of the esophageal body or esophagogastric region. The authors review the radiological evaluation of the esophagus and esophagogastric region in patients with esophageal dysphagia and discuss the roentgenographic techniques used, radiological efficacy for common structural disorders, and evaluation of esophageal motor function. Comparison is made with endoscopy in assessing dysphagia, with the conclusion that the radiological examination be used initially in patients with this complaint.

  14. Radiological evaluation of dysphagia

    International Nuclear Information System (INIS)

    Ott, D.J.; Gelfand, D.W.; Wu, W.C.; Chen, Y.M.

    1986-01-01

    Dysphagia is a common complaint in patients presenting for radiological or endoscopic examination of the esophagus and is usually due to functional or structural abnormalities of the esophageal body or esophagogastric region. The authors review the radiological evaluation of the esophagus and esophagogastric region in patients with esophageal dysphagia and discuss the roentgenographic techniques used, radiological efficacy for common structural disorders, and evaluation of esophageal motor function. Comparison is made with endoscopy in assessing dysphagia, with the conclusion that the radiological examination be used initially in patients with this complaint

  15. Evidence for the distortion product frequency place as a source of distortion product otoacoustic emission (DPOAE) fine structure in humans : II. Fine structure for different shapes of cochlear hearing loss

    NARCIS (Netherlands)

    Mauermann, M; Uppenkamp, S; van Hengel, P.W.J.; Kollmeier, B

    1999-01-01

    Distortion product otoacoustic emissions (DPOAE) were recorded from eight human subjects with mild to moderate cochlear hearing loss, using a frequency spacing of 48 primary pairs per octave and at a level L(1) = L(2) = 60 dBSPL and with a fixed ratio f(2)/f(1). Subjects with different shapes of

  16. Pannus inflammation in sacroiliitis following immune pathological injury and radiological structural damage: a study of 193 patients with spondyloarthritis.

    Science.gov (United States)

    Wang, Dan Min; Lin, Ling; Peng, Jian Hua; Gong, Yao; Hou, Zhi Duo; Chen, Su Biao; Xiao, Zheng Yu

    2018-06-08

    The pathogenesis of sacroiliitis is unclear; therefore, we aimed to systematically study the immunopathology of sacroiliitis in patients with axial spondyloarthritis (axSpA), and explore the relationship between pannus formation, inflammation, and the structural damage caused by sacroiliitis. Fine needle aspiration biopsy of the sacroiliac joint (SIJ) was performed in 193 patients with axSpA. Clinical, laboratory, and imaging data were collected at baseline and during the follow up. Immunohistochemistry analysis was performed to detect CD34+ microvessels, CD68+ osteoclasts/macrophages, vascular endothelial growth factor (VEGF), metalloproteinase-3 (MMP-3), tumor necrosis factor-α (TNF-α), and caspase-3. Autopsy subjects were used as controls. In early sacroiliitis (grade 0-1) all pathological features could be observed, with the most common being subchondral pannus formation. Among the 193 patients, 98 were followed up for 1-13 years (mean 3.6 years); 63.3% had radiological progression at the endpoint. Multiple regression analysis showed that cartilage pannus invasion (OR 2.99, P = 0.010) and endochondral ossification (OR 3.97, P = 0.049) at baseline were risk factors for radiological structural damage. Compared to SIJ controls, the subchondral microvessel density, number of CD68+ multinuclear osteoclasts, and the levels of VEGF, caspase-3, MMP-3, and TNF-α expressed at the interface of the bone and cartilage were significantly higher in patients with sacroiliitis. Subchondral fibrovascular tissue formation is the most important pathological feature in early sacroiliitis. The existence of cartilage pannus invasion or endochondral ossification at baseline can predict radiological structural damage during the follow up.

  17. Congenitally Deafblind Children and Cochlear Implants

    DEFF Research Database (Denmark)

    Dammeyer, Jesper Herup

    2008-01-01

    There has been much research conducted demonstrating the positive benefits of cochlear implantation (CI) in children who are deaf. Research on cochlear implantation in children who are both deaf and blind, however, is lacking. The purpose of this article is to present a study of 5 congenitally...... deafblind children who received cochlear implants between 2.2 and 4.2 years of age.  Ratings of video observations were used to measure the children's early communication development with and without the use of their cochlear implants. In addition, parental interviews were used to assess the benefits...... parents perceived regarding their children's cochlear implants. Two examples are included in this article to illustrate the parents' perspectives about cochlear implantation in their deafblind children. Benefits of cochlear implantation in this cohort of children included improved attention and emotional...

  18. [Bilateral cochlear implants].

    Science.gov (United States)

    Müller, J

    2017-07-01

    Cochlear implants (CI) are standard for the hearing rehabilitation of severe to profound deafness. Nowadays, if bilaterally indicated, bilateral implantation is usually recommended (in accordance with German guidelines). Bilateral implantation enables better speech discrimination in quiet and in noise, and restores directional and spatial hearing. Children with bilateral CI are able to undergo hearing-based hearing and speech development. Within the scope of their individual possibilities, bilaterally implanted children develop faster than children with unilateral CI and attain, e.g., a larger vocabulary within a certain time interval. Only bilateral implantation allows "binaural hearing," with all the benefits that people with normal hearing profit from, namely: better speech discrimination in quiet and in noise, as well as directional and spatial hearing. Naturally, the developments take time. Binaural CI users benefit from the same effects as normal hearing persons: head shadow effect, squelch effect, and summation and redundancy effects. Sequential CI fitting is not necessarily disadvantageous-both simultaneously and sequentially fitted patients benefit in a similar way. For children, earliest possible fitting and shortest possible interval between the two surgeries seems to positively influence the outcome if bilateral CI are indicated.

  19. [Cochlear implant in patients with congenital malformation of the inner ear].

    Science.gov (United States)

    Wan, Liang-cai; Guo, Meng-he; Qian, Yu-hong; Liu, Shuang-xiu; Zhang, Hong-zheng; Chen, Shuai-jun; Chen, Hao; Gong, Jian

    2009-10-01

    To summarize the clinical experience with multi-channel cochlear implantation in patients with inner ear malformations and evaluate and the outcomes of speech rehabilitation. A retrospective study was conducted in 295 patients receiving cochlear implantation from 1998 to 2007, including 25 patients with large vestibular aqueduct syndrome (LVAS), 9 with Modini malformation, and 5 with common cavity deformity. All the patients received the Nucleus24 cochlear implants. In LVAS cases, 4 had Nucleus 24R (ST) implants, 8 had Contuor implants, 10 had Contuor Advance, and the remaining cases used Nucleus24(M) straight-electrode implants. Severe gusher appeared in 3 cases of LVAS, and perilymph fluctuation were seen in other 15 cases. Four patients with Mondini malformation and 2 with common cavity malformation also experienced severe gusher, but the electrodes were inserted smoothly in all the patients without postoperative facial paralysis or cerebrospinal fluid leakage. The hearing threshold in these patients was similar to that in patients with normal cochlear structure. After speech rehabilitation for over 6 months, the abilities of speech discrimination and spoken language improved in all the cases in comparison with the preoperative lingual functions. Multi-channel cochlear implantation can be performed in patients with inner ear malformation, but should not be attempted in patients with poor cochlear and cochlear nerve development. A comprehensive pre-operative radiographic and audiological evaluation is essential.

  20. The application of improved, structured and interactive group learning methods in diagnostic radiology

    International Nuclear Information System (INIS)

    Ivarsson, Jonas; Rystedt, Hans; Baath, Magnus; Asplund, Sara; Allansdotter Johnsson, Aase

    2016-01-01

    This study provides an example on how it is possible to design environments in a diagnostic radiology department that could meet learning demands implied by the introduction of new imaging technologies. The innovative aspect of the design does not result from the implementation of any specific tool for learning. Instead, advancement is achieved by a novel set-up of existing technologies and an interactive format that allows for focussed discussions between learners with different levels of expertise. Consequently, the study points to what is seen as the under-explored possibilities of tailoring basic and specialist training that meet the new demands given by leading-edge technologies. (authors)

  1. Occupational safety and health textbook for radiological personnel employed in structural material testing

    International Nuclear Information System (INIS)

    Abraham, J.

    1981-01-01

    The comprehensive textbook for X-ray and radiological testing personnel includes requirements and rules of occupational safety and health on the basis of Hungarian and international (mainly German) literature. In the chapter Fundamentals, X-ray and radioactive radiations, their measurements and biological effects, doses etc are described. In the chapter Occupational safety and health, the jobs representing radiation hazards are listed and safety regulations for them are reported. Finally, information for prevention and first aid is presented. Control questions are added to each part. The Appendix contains safety standards and regulations, information on legal aspects of safety and radiation protection as well as recommendations. (Sz.J.)

  2. Reading skills after cochlear implantation

    NARCIS (Netherlands)

    Vermeulen, A.M.

    2007-01-01

    It has frequently been found that profoundly deaf children with conventional hearing aids have difficulties with the comprehension of written text. Cochlear Implants (CIs) were expected to enhance the reading comprehension of these profoundly deaf children because they provide auditory access to

  3. Advancing Binaural Cochlear Implant Technology

    Directory of Open Access Journals (Sweden)

    Mathias Dietz

    2015-12-01

    Full Text Available This special issue contains a collection of 13 papers highlighting the collaborative research and engineering project entitled Advancing Binaural Cochlear Implant Technology—ABCIT—as well as research spin-offs from the project. In this introductory editorial, a brief history of the project is provided, alongside an overview of the studies.

  4. [Cochlear implant treatment in Germany].

    Science.gov (United States)

    Jacob, R; Stelzig, Y

    2013-01-01

    Restoration of impaired auditory function through cochlear implant is possible, with high reliably and great success. Nevertheless, there are regular disputes between patients and insurance companies due to high costs. In Germany, approx. 1.9 Mio. people are severely hearing impaired. It can be estimated that for adequate hearing rehabilitation about 30,000 cochlear implants/year are necessary. Currently, less than 10% of those affected are offered cochlear implant. A handicap is defined if there is deviation from normal hearing for more than 6 months. This sets a time frame for the supply with cochlear implant after sudden deafness. The professional code requires to advice all medical options to a person seeking help for hearing loss. This includes benefit-risk consideration. At this point, the economic aspect plays no role. The indication for medical treatment is only subject to the treating physician and should not be modified by non-physicians or organizations. It should be noted that a supply of hearing aids is qualitatively different to the help from a cochlear implant, which provides a restoration of lost function. In social law (SGB V and IX) doctors are requested to advise and recommend all measures which contribute to normal hearing (both sides). This indicates that doctors may be prosecuted for not offering help when medically possible, just because health insurance employees did not approve the cost balance. The current situation, with insufficient medical care for the hearing impaired, needs clarifying. To do this, patients, health insurance companies, the political institutions, legislation and professional societies need to accept their responsibilities.

  5. [Pre-operation evaluation and intra-operation management of cochlear implantation].

    Science.gov (United States)

    Zhang, Dao-xing; Hu, Bao-hua; Xiao, Yu-li; Shi, Bo-ning

    2004-10-01

    To summarize pre-operation evaluation experiences in cochlear implantation. Performing auditory evaluation and image analysis seriously in 158 severe hearing loss or total deaf cases before cochlear implantation, comparing their performance with the findings during and post operation. Among the total 158 cases, 116 cases with normal structure, 42 cases with the abnormal findings of the inner or middle ear. Stapedial gusher happened in 6 cases, 1 case was not predicted before operation. Except 1 case with serious malformation, the findings of other 157 cases in operation were consistent with the pre-operation evaluation. We helped all patients reconstruct auditory conduction with cochlear implantation, and the average hearing level up to 37.6 dB SPL. Performing image analysis seriously before operation and planning for operation according to HRCT can do great help to cochlear implantation. The operation under the HRCT instruction has less complications.

  6. Diversity in cochlear morphology and its influence on cochlear implant electrode position

    NARCIS (Netherlands)

    Marel, K.S. van der; Briaire, J.J.; Wolterbeek, R..; Snel-Bongers, J.; Verbist, B.M.; Frijns, J.H.

    2014-01-01

    To define a minimal set of descriptive parameters for cochlear morphology and study its influence on the cochlear implant electrode position in relation to surgical insertion distance.Cochlear morphology and electrode position were analyzed using multiplanar reconstructions of the pre- and

  7. Radiological English

    Energy Technology Data Exchange (ETDEWEB)

    Ribes, R. [Hospital Reina Sofia, Cordoba (Spain). Servicio de Radiologia; Ros, P.R. [Harvard Medical School, Boston, MA (United States). Div. of Radiology

    2007-07-01

    The book is an introductory book to radiological English on the basis that there are a lot of radiologists, radiology residents, radiology nurses, radiology students, and radiographers worldwide whose English level is indeterminate because their reading skills are much higher than their fluency. It is intended to help those health care professionals who need English for their work but do not speak English on a day-to-day basis. (orig.)

  8. Radiological English

    International Nuclear Information System (INIS)

    Ribes, R.; Ros, P.R.

    2007-01-01

    The book is an introductory book to radiological English on the basis that there are a lot of radiologists, radiology residents, radiology nurses, radiology students, and radiographers worldwide whose English level is indeterminate because their reading skills are much higher than their fluency. It is intended to help those health care professionals who need English for their work but do not speak English on a day-to-day basis. (orig.)

  9. Factors contributing to communication skills development in cochlear implanted children.

    Science.gov (United States)

    Ostojić, Sanja; Djoković, Sanja; Radić-šestić, Marina; Nikolić, Mina; Mikić, Branka; Mirić, Danica

    2015-08-01

    Over the last 10 years more than 300 persons received cochlear implant in Serbia and more than 90% of the recipients were children under 10 years of age. The program of cochlear implantation includes postoperative rehabilitation in which cognitive, integrative and developmental methods are used. The study was conducted to reveal factors affecting communication performance (CP) of cochlear implanted (Cl) children. Special attention was focused on the influence of the duration and intensity of rehabilitation and hearing age on further development of communication skills. A group of 30 CI children (13 boys and 17 girls) aged 2 to 5 years was enrolled in the study. All of the children had average intelligence and no other developmental disorder. They lived in families and attended rehabilitative seances 3 to 5 times a week. Their parents/caregivers answered structured questionnaire about functioning after pediatric cochlear implantation (FAPCI) and the results were the subject of detailed statistical analysis. Analysis of variance did not show any difference between the boys and the girls regarding FAPCI achievements (F(1, 28) = 2.909; p = 0.099) and age aberration in CP score (F(1,28) = 0.114, p = 0.738). Correlation analysis showed a statistically significant difference in FAPCI scores related to hearing age and duration of rehabilitation. Regression analysis (enter method) showed that model consisting of indipendent variables significantly contributed to prediction of overall FAPCI scores and Adjusted R2 value could explain 32% difference in communication skills of participants in this study. Communication skills of CI children evaluated by FAPCI are falling behind normatives for normal hearing children 18.6 months on the average. Hearing age, duration and intensity of rehabilitation have positive predictive value for communication skills development. Later identification of hearing loss and later cochlear implantation lead to delayed development of communication

  10. Cochlear implant revision surgeries in children.

    Science.gov (United States)

    Amaral, Maria Stella Arantes do; Reis, Ana Cláudia Mirândola B; Massuda, Eduardo T; Hyppolito, Miguel Angelo

    2018-02-16

    The surgery during which the cochlear implant internal device is implanted is not entirely free of risks and may produce problems that will require revision surgeries. To verify the indications for cochlear implantation revision surgery for the cochlear implant internal device, its effectiveness and its correlation with certain variables related to language and hearing. A retrospective study of patients under 18 years submitted to cochlear implant Surgery from 2004 to 2015 in a public hospital in Brazil. Data collected were: age at the time of implantation, gender, etiology of the hearing loss, audiological and oral language characteristics of each patient before and after Cochlear Implant surgery and any need for surgical revision and the reason for it. Two hundred and sixty-five surgeries were performed in 236 patients. Eight patients received a bilateral cochlear implant and 10 patients required revision surgery. Thirty-two surgeries were necessary for these 10 children (1 bilateral cochlear implant), of which 21 were revision surgeries. In 2 children, cochlear implant removal was necessary, without reimplantation, one with cochlear malformation due to incomplete partition type I and another due to trauma. With respect to the cause for revision surgery, of the 8 children who were successfully reimplanted, four had cochlear calcification following meningitis, one followed trauma, one exhibited a facial nerve malformation, one experienced a failure of the cochlear implant internal device and one revision surgery was necessary because the electrode was twisted. The incidence of the cochlear implant revision surgery was 4.23%. The period following the revision surgeries revealed an improvement in the subject's hearing and language performance, indicating that these surgeries are valid in most cases. Copyright © 2018 Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial. Published by Elsevier Editora Ltda. All rights reserved.

  11. New data on structure and radiological age of formations of Lapland granulite belt (Kandalaksha Shore of the White Sea)

    Energy Technology Data Exchange (ETDEWEB)

    Sukhanov, M K; Terekhov, E N; Levitskij, V I

    1987-01-01

    The structure and radiological age of granulite belt rocks along the White Sea shore from West to East have been investigated by the uranium-lead thermoisochronous method. The age of granulite metamorphism in the White Sea shore and Kola blocks, which separate the granulite belt, is estimated as 2.5-2.7 milliard years; the boundary for metamorphic transformations (1.8 milliard years) is distinctly fixed for granulite belt rocks. The most ancient values for ages have been obtained by zircons of biotite gneisses -2.7-2.8 milliard years, and from granite shingles in conglomerates, in zircons of which the value of 2.9 milliard years is fixed.

  12. Radiology fundamentals

    CERN Document Server

    Singh, Harjit

    2011-01-01

    ""Radiology Fundamentals"" is a concise introduction to the dynamic field of radiology for medical students, non-radiology house staff, physician assistants, nurse practitioners, radiology assistants, and other allied health professionals. The goal of the book is to provide readers with general examples and brief discussions of basic radiographic principles and to serve as a curriculum guide, supplementing a radiology education and providing a solid foundation for further learning. Introductory chapters provide readers with the fundamental scientific concepts underlying the medical use of imag

  13. RSVP radiology

    International Nuclear Information System (INIS)

    Kirks, D.R.; Chaffee, D.J.

    1990-01-01

    This paper develops a relative scale of value for pediatric radiology (RSVPR). Neither the HCFA/ACA Relative Value Scale nor the Workload Measurement System developed by Health and Welfare Canada specifically addressed pediatric radiologic examinations. Technical and professional charges for examinations at Children's Hospital Medical Center were reviewed and compared with time and cost analysis. A scale was developed with chest radiography (PA and lateral views) assigned a value of 1. After review by pediatric radiologic technologists, radiologic administrators, pediatric radiologists, and chairs of departments of children's hospitals, this proposed scale was modified to reflect more accurately relative value components of pediatric radiologic and imaging examinations

  14. CT evaluation of preoperative cochlear implantation cochlear implantation

    International Nuclear Information System (INIS)

    Tan Xiuzhong; Zhong Lansheng; Lan Bowen; Huang Yaosheng; Du Baowen; Zhu Jian

    2004-01-01

    Objective: To evaluate CT scan as a preoperative evaluation for cochlear implantation candidates. Methods: Axial high-resolution temporal bone CT and three-dimensional reconstruction of inner ear were performed in 93 patients with sensorineural hearing loss. results: Among 81 patients with congenital sensorineural deafness, Mondini malformation was seen in 7 case (13 ears); large vestibular aqueduct syndrome (LVAS) was revealed in 5 cases (8 ears); and inner ear ossification was found in 1 case (2 ears). In 1 case (2 ears) of inner ear fibrosis, reduced cochlear signal was noted on MRI but no unremarkable findings was shown on CT scan, however, in the operation, the device could not inserted into the basal circle of the cochlea, due to fibrous obliteration. In 12 patients with post-speech deafness, chronic suppurative tympanitis was seen in 2 cases (4 ears), and inner ear ossification was revealed in 1 case (2 ears). Conclusion: CT plays an indispensable role in the pre-operative evaluation of cochlear implantation. T 2 -weighted FSE-MRI of the inner ear is a useful complementary to CT scan. (authors)

  15. Serotonin projection patterns to the cochlear nucleus.

    Science.gov (United States)

    Thompson, A M; Thompson, G C

    2001-07-13

    The cochlear nucleus is well known as an obligatory relay center for primary auditory nerve fibers. Perhaps not so well known is the neural input to the cochlear nucleus from cells containing serotonin that reside near the midline in the midbrain raphe region. Although the specific locations of the main, if not sole, sources of serotonin within the dorsal cochlear nucleus subdivision are known to be the dorsal and median raphe nuclei, sources of serotonin located within other cochlear nucleus subdivisions are not currently known. Anterograde tract tracing was used to label fibers originating from the dorsal and median raphe nuclei while fluorescence immunohistochemistry was used to simultaneously label specific serotonin fibers in cat. Biotinylated dextran amine was injected into the dorsal and median raphe nuclei and was visualized with Texas Red, while serotonin was visualized with fluorescein. Thus, double-labeled fibers were unequivocally identified as serotoninergic and originating from one of the labeled neurons within the dorsal and median raphe nuclei. Double-labeled fiber segments, typically of fine caliber with oval varicosities, were observed in many areas of the cochlear nucleus. They were found in the molecular layer of the dorsal cochlear nucleus, in the small cell cap region, and in the granule cell and external regions of the cochlear nuclei, bilaterally, of all cats. However, the density of these double-labeled fiber segments varied considerably depending upon the exact region in which they were found. Fiber segments were most dense in the dorsal cochlear nucleus (especially in the molecular layer) and the large spherical cell area of the anteroventral cochlear nucleus; they were moderately dense in the small cell cap region; and fiber segments were least dense in the octopus and multipolar cell regions of the posteroventral cochlear nucleus. Because of the presence of labeled fiber segments in subdivisions of the cochlear nucleus other than the

  16. Radiology illustrated. Pediatric radiology

    Energy Technology Data Exchange (ETDEWEB)

    Kim, In-One (ed.) [Seoul National Univ. College of Medicine (Korea, Republic of). Dept. of Radiology

    2014-11-01

    Depicts characteristic imaging findings of common and uncommon diseases in the pediatric age group. Will serve as an ideal diagnostic reference in daily practice. Offers an excellent teaching aid, with numerous high-quality illustrations. This case-based atlas presents images depicting the findings typically observed when imaging a variety of common and uncommon diseases in the pediatric age group. The cases are organized according to anatomic region, covering disorders of the brain, spinal cord, head and neck, chest, cardiovascular system, gastrointestinal system, genitourinary system, and musculoskeletal system. Cases are presented in a form resembling teaching files, and the images are accompanied by concise informative text. The goal is to provide a diagnostic reference suitable for use in daily routine by both practicing radiologists and radiology residents or fellows. The atlas will also serve as a teaching aide and a study resource, and will offer pediatricians and surgeons guidance on the clinical applications of pediatric imaging.

  17. Essential items for structured reporting of rectal cancer MRI: 2016 consensus recommendation from the Korean society of abdominal radiology

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2017-01-15

    High-resolution rectal MRI plays a crucial role in evaluating rectal cancer by providing multiple prognostic findings and imaging features that guide proper patient management. Quality reporting is critical for accurate effective communication of the information among multiple disciplines, for which a systematic structured approach is beneficial. Existing guides on reporting of rectal MRI are divergent on some issues, largely reflecting the differences in overall management of rectal cancer patients between the United States and Europe. The Korean Society of Abdominal Radiology (KSAR) study group for rectal cancer has developed an expert consensus recommendation regarding essential items for structured reporting of rectal cancer MRI using a modified Delphi method. This recommendation aims at presenting an up-to-date, evidence-based, practical, structured reporting template that can be readily adopted in daily clinical practice. In addition, a thorough explanation of the clinical and scientific rationale underlying the reporting items and their formats is provided. This KSAR recommendation may serve as a useful tool to help achieve more standardized optimal care for rectal cancer patients using rectal MRI.

  18. Essential items for structured reporting of rectal cancer MRI: 2016 consensus recommendation from the Korean society of abdominal radiology

    International Nuclear Information System (INIS)

    2017-01-01

    High-resolution rectal MRI plays a crucial role in evaluating rectal cancer by providing multiple prognostic findings and imaging features that guide proper patient management. Quality reporting is critical for accurate effective communication of the information among multiple disciplines, for which a systematic structured approach is beneficial. Existing guides on reporting of rectal MRI are divergent on some issues, largely reflecting the differences in overall management of rectal cancer patients between the United States and Europe. The Korean Society of Abdominal Radiology (KSAR) study group for rectal cancer has developed an expert consensus recommendation regarding essential items for structured reporting of rectal cancer MRI using a modified Delphi method. This recommendation aims at presenting an up-to-date, evidence-based, practical, structured reporting template that can be readily adopted in daily clinical practice. In addition, a thorough explanation of the clinical and scientific rationale underlying the reporting items and their formats is provided. This KSAR recommendation may serve as a useful tool to help achieve more standardized optimal care for rectal cancer patients using rectal MRI

  19. 3D Models of Female Pelvis Structures Reconstructed and Represented in Combination with Anatomical and Radiological Sections.

    Science.gov (United States)

    Asensio Romero, L; Asensio Gómez, M; Prats-Galino, A; Juanes Méndez, J A

    2018-01-15

    We present a computer program designed to visualize and interact with three-dimensional models of the main anatomical structures of the female pelvis. They are reconstructed from serial sections of corpse, from the Visible Human project of the Medical Library of the United States and from serial sections of high-resolution magnetic resonance. It is possible to represent these three-dimensional structures in any spatial orientation, together with sectional images of corpse and magnetic resonance imaging, in the three planes of space (axial, coronal and sagittal) that facilitates the anatomical understanding and the identification of the set of visceral structures of this body region. Actually, there are few studies that analysze in detail the radiological anatomy of the female pelvis using three-dimensional models together with sectional images, making use of open applications for the representation of virtual scenes on low cost Windows® platforms. Our technological development allows the observation of the main female pelvis viscera in three dimensions with a very intuitive graphic interface. This computer application represents an important training tool for both medical students and specialists in gynecology and as a preliminary step in the planning of pelvic floor surgery.

  20. The development of auditory skills in young children with Mondini dysplasia after cochlear implantation.

    Directory of Open Access Journals (Sweden)

    Xueqing Chen

    Full Text Available The aim of this study is to survey and compare the development of auditory skills in young children with Mondini dysplasia and profoundly-deaf young children with radiologically normal inner ears over a period of 3 years after cochlear implantation. A total of 545 young children (age 7 to 36 months with prelingual, severe to profound hearing loss participated in this study. All children received cochlear implantation. Based on whether or not there was a Mondini dysplasia as diagnosed with CT scanning, the subjects were divided into 2 groups: (A 514 young children with radiologically normal inner ears and (B 31 young children with Mondini dysplasia. The Infant-Toddler Meaningful Auditory Integration Scale (IT-MAIS was used to assess the children's auditory skills that include vocalization changes, spontaneous alerting to sounds in everyday living environments, and the ability to derive meaning from sounds. The assessment was performed prior to surgery and at 1, 3, 6, 9, 12, 24, and 36 months after implant device switch-on. The mean scores for overall auditory skills were not significantly different between groups A and B at pre-surgery, 1, 12, 24, and 36 months post-surgery, but were significantly different at 3, 6, and 9 months post-surgery. The mean scores for all auditory skills in children with Mondini dysplasia showed significant improvement over time. The mean scores for the three subcategories of auditory skills in children with Mondini dysplasia also showed significant differences at pre-surgery, 1, 3, 6, and 9 months, however, there were no significant differences at 12, 24, and 36 months. Overall, the auditory skills of young children with Mondini dysplasia developed rapidly after cochlear implantation, in a similar manner to that of young children with radiologically normal inner ears. Cochlear implantation is an effective intervention for young children with Mondini dysplasia.

  1. Deafblind People's Experiences of Cochlear Implantation

    Science.gov (United States)

    Soper, Janet

    2006-01-01

    Cochlear implants are electronic devices that create the sensation of hearing in those who cannot obtain any benefit from conventional hearing aids. This article examines the experience of cochlear implantation in a select group of individuals with acquired deafblindness, focusing on three key themes: access to communication, information and…

  2. Referral expectations of radiology

    International Nuclear Information System (INIS)

    Smith, W.L.; Altmaier, E.; Berberoglu, L.; Morris, K.

    1989-01-01

    The expectation of the referring physician are key to developing a successful practice in radiology. Structured interviews with 17 clinicians in both community care and academic practice documented that accuracy of the radiologic report was the single most important factor in clinician satisfaction. Data intercorrelation showed that accuracy of report correlated with frequency of referral (r = .49). Overall satisfaction of the referring physician with radiology correlated with accuracy (r = .69), patient satisfaction (r = .36), and efficiency in archiving (r = .42). These data may be weighted by departmental managers to allocate resources for improving referring physician satisfaction

  3. [Controlling instruments in radiology].

    Science.gov (United States)

    Maurer, M

    2013-10-01

    Due to the rising costs and competitive pressures radiological clinics and practices are now facing, controlling instruments are gaining importance in the optimization of structures and processes of the various diagnostic examinations and interventional procedures. It will be shown how the use of selected controlling instruments can secure and improve the performance of radiological facilities. A definition of the concept of controlling will be provided. It will be shown which controlling instruments can be applied in radiological departments and practices. As an example, two of the controlling instruments, material cost analysis and benchmarking, will be illustrated.

  4. Importance of cochlear health for implant function.

    Science.gov (United States)

    Pfingst, Bryan E; Zhou, Ning; Colesa, Deborah J; Watts, Melissa M; Strahl, Stefan B; Garadat, Soha N; Schvartz-Leyzac, Kara C; Budenz, Cameron L; Raphael, Yehoash; Zwolan, Teresa A

    2015-04-01

    Amazing progress has been made in providing useful hearing to hearing-impaired individuals using cochlear implants, but challenges remain. One such challenge is understanding the effects of partial degeneration of the auditory nerve, the target of cochlear implant stimulation. Here we review studies from our human and animal laboratories aimed at characterizing the health of the implanted cochlea and the auditory nerve. We use the data on cochlear and neural health to guide rehabilitation strategies. The data also motivate the development of tissue-engineering procedures to preserve or build a healthy cochlea and improve performance obtained by cochlear implant recipients or eventually replace the need for a cochlear implant. This article is part of a Special Issue entitled . Copyright © 2014 Elsevier B.V. All rights reserved.

  5. Temporal and spectral contributions to musical instrument identification and discrimination among cochlear implant users.

    Science.gov (United States)

    Prentiss, Sandra M; Friedland, David R; Fullmer, Tanner; Crane, Alison; Stoddard, Timothy; Runge, Christina L

    2016-09-01

    To investigate the contributions of envelope and fine-structure to the perception of timbre by cochlear implant (CI) users as compared to normal hearing (NH) listeners. This was a prospective cohort comparison study. Normal hearing and cochlear implant patients were tested. Three experiments were performed in sound field using musical notes altered to affect the characteristic pitch of an instrument and the acoustic envelope. Experiment 1 assessed the ability to identify the instrument playing each note, while experiments 2 and 3 assessed the ability to discriminate the different stimuli. Normal hearing subjects performed better than CI subjects in all instrument identification tasks, reaching statistical significance for 4 of 5 stimulus conditions. Within the CI population, acoustic envelope modifications did not significantly affect instrument identification or discrimination. With envelope and pitch cues removed, fine structure discrimination performance was similar between normal hearing and CI users for the majority of conditions, but some specific instrument comparisons were significantly more challenging for CI users. Cochlear implant users perform significantly worse than normal hearing listeners on tasks of instrument identification. However, cochlear implant listeners can discriminate differences in envelope and some fine structure components of musical instrument sounds as well as normal hearing listeners. The results indicated that certain fine structure cues are important for cochlear implant users to make discrimination judgments, and therefore may affect interpretation toward associating with a specific instrument for identification.

  6. Temporal and spectral contributions to musical instrument identification and discrimination among cochlear implant users

    Institute of Scientific and Technical Information of China (English)

    Sandra M. Prentiss; David R. Friedland; Tanner Fullmer; Alison Crane; Timothy Stoddard; Christina L. Runge

    2016-01-01

    Objective:To investigate the contributions of envelope and fine-structure to the perception of timbre by cochlear implant (CI) users as compared to normal hearing (NH) lis-teners. Methods: This was a prospective cohort comparison study. Normal hearing and cochlear implant patients were tested. Three experiments were performed in sound field using musical notes altered to affect the characteristic pitch of an instrument and the acoustic envelope. Experiment 1 assessed the ability to identify the instrument playing each note, while experi-ments 2 and 3 assessed the ability to discriminate the different stimuli. Results:Normal hearing subjects performed better than CI subjects in all instrument identifi-cation tasks, reaching statistical significance for 4 of 5 stimulus conditions. Within the CI pop-ulation, acoustic envelope modifications did not significantly affect instrument identification or discrimination. With envelope and pitch cues removed, fine structure discrimination perfor-mance was similar between normal hearing and CI users for the majority of conditions, but some specific instrument comparisons were significantly more challenging for CI users. Conclusions:Cochlear implant users perform significantly worse than normal hearing listeners on tasks of instrument identification. However, cochlear implant listeners can discriminate differences in envelope and some fine structure components of musical instrument sounds as well as normal hearing listeners. The results indicated that certain fine structure cues are important for cochlear implant users to make discrimination judgments, and therefore may affect interpretation toward associating with a specific instrument for identification.

  7. Chronicle of pediatric radiology

    International Nuclear Information System (INIS)

    Benz-Bohm, Gabriele; Richter, Ernst

    2012-01-01

    The chronicle of pediatric radiology covers the following issues: Development of pediatric radiology in Germany (BRD, DDR, pediatric radiological accommodations); development of pediatric radiology in the Netherlands (chronology and pediatric radiological accommodations); development of pediatric radiology in Austria (chronology and pediatric radiological accommodations); development of pediatric radiology in Switzerland (chronology and pediatric radiological accommodations).

  8. Aspects of Music with Cochlear Implants – Music Listening Habits and Appreciation in Danish Cochlear Implant Users

    DEFF Research Database (Denmark)

    Petersen, Bjørn; Hansen, Mads; Sørensen, Stine Derdau

    Cochlear implant users differ significantly from their normal hearing peers when it comes to perception of music. Several studies have shown that structural features – such as rhythm, timbre, and pitch – are transmitted less accurately through an implant. However, we cannot predict personal...... music less post-implantation than prior to their hearing loss. Nevertheless, a large majority of CI listeners either prefer music over not hearing music at all or find music as pleasant as they recall it before their hearing loss, or more so....... enjoyment of music solely as a function of accuracy of perception. But can music be pleasant with a cochlear implant at all? Our aim here was to gather information of both music enjoyment and listening habits before the onset of hearing loss and post-operation from a large, representative sample of Danish...

  9. Dental radiology

    International Nuclear Information System (INIS)

    Bhaskar, S.N.

    1982-01-01

    The book presents the radiological manifestations of the maxillodental region in a suitable manner for fast detection and correct diagnosing of diseases of the teeth, soft tissue, and jaws. Classification therefore is made according to the radiological manifestations of the diseases and not according to etiology. (orig./MG) [de

  10. Audiovisual segregation in cochlear implant users.

    Directory of Open Access Journals (Sweden)

    Simon Landry

    Full Text Available It has traditionally been assumed that cochlear implant users de facto perform atypically in audiovisual tasks. However, a recent study that combined an auditory task with visual distractors suggests that only those cochlear implant users that are not proficient at recognizing speech sounds might show abnormal audiovisual interactions. The present study aims at reinforcing this notion by investigating the audiovisual segregation abilities of cochlear implant users in a visual task with auditory distractors. Speechreading was assessed in two groups of cochlear implant users (proficient and non-proficient at sound recognition, as well as in normal controls. A visual speech recognition task (i.e. speechreading was administered either in silence or in combination with three types of auditory distractors: i noise ii reverse speech sound and iii non-altered speech sound. Cochlear implant users proficient at speech recognition performed like normal controls in all conditions, whereas non-proficient users showed significantly different audiovisual segregation patterns in both speech conditions. These results confirm that normal-like audiovisual segregation is possible in highly skilled cochlear implant users and, consequently, that proficient and non-proficient CI users cannot be lumped into a single group. This important feature must be taken into account in further studies of audiovisual interactions in cochlear implant users.

  11. Assessment of Cochlear Function during Cochlear Implantation by Extra- and Intracochlear Electrocochleography

    OpenAIRE

    Dalbert, Adrian; Pfiffner, Flurin; Hoesli, Marco; Koka, Kanthaiah; Veraguth, Dorothe; Roosli, Christof; Huber, Alexander

    2018-01-01

    Objective: The aims of this study were: (1) To investigate the correlation between electrophysiological changes during cochlear implantation and postoperative hearing loss, and (2) to detect the time points that electrophysiological changes occur during cochlear implantation. Material and Methods: Extra- and intracochlear electrocochleography (ECoG) were used to detect electrophysiological changes during cochlear implantation. Extracochlear ECoG recordings were conducted through a needle elec...

  12. Development of micro-electromechanical system (MEMS) cochlear biomodel

    Energy Technology Data Exchange (ETDEWEB)

    Ngelayang, Thailis Bounya Anak; Latif, Rhonira [Faculty of Electronic and Computer Engineering, Universiti Teknikal Malaysia Melaka, Hang Tuah Jaya, 76100 Durian Tunggal, Melaka (Malaysia)

    2015-05-15

    Human cochlear is undeniably one of the most amazing organs in human body. The functional mechanism is very unique in terms of its ability to convert the sound waves in the form of mechanical vibrations into the electrical nerve impulses. It is known that the normal human auditory system can perceive the audible frequency range between 20 Hz to 20 kHz. Scientists have conducted several researches trying to build the artificial basilar membrane in the human cochlea (cochlear biomodel). Micro-electromechanical system (MEMS) is one of the potential inventions that have the ability to mimic the active behavior of the basilar membrane. In this paper, an array of MEMS bridge beams that are mechanically sensitive to the perceived audible frequency has been proposed. An array of bridge bridge beams with 0.5 µm thickness and length varying from 200 µm to 2000 µm have been designed operate within the audible frequency range. In the bridge beams design, aluminium (Al), copper (Cu), tantalum (Ta) and platinum (Pt) have considered as the material for the bridge beam structure. From the finite element (FE) and lumped element (LE) models of the MEMS bridge beams, platinum has been found to be the best material for the cochlear biomodel design, closely mimicking the basilar membrane.

  13. Development of micro-electromechanical system (MEMS) cochlear biomodel

    International Nuclear Information System (INIS)

    Ngelayang, Thailis Bounya Anak; Latif, Rhonira

    2015-01-01

    Human cochlear is undeniably one of the most amazing organs in human body. The functional mechanism is very unique in terms of its ability to convert the sound waves in the form of mechanical vibrations into the electrical nerve impulses. It is known that the normal human auditory system can perceive the audible frequency range between 20 Hz to 20 kHz. Scientists have conducted several researches trying to build the artificial basilar membrane in the human cochlea (cochlear biomodel). Micro-electromechanical system (MEMS) is one of the potential inventions that have the ability to mimic the active behavior of the basilar membrane. In this paper, an array of MEMS bridge beams that are mechanically sensitive to the perceived audible frequency has been proposed. An array of bridge bridge beams with 0.5 µm thickness and length varying from 200 µm to 2000 µm have been designed operate within the audible frequency range. In the bridge beams design, aluminium (Al), copper (Cu), tantalum (Ta) and platinum (Pt) have considered as the material for the bridge beam structure. From the finite element (FE) and lumped element (LE) models of the MEMS bridge beams, platinum has been found to be the best material for the cochlear biomodel design, closely mimicking the basilar membrane

  14. Cochlear implantation in patient with Dandy-walker syndrome.

    Science.gov (United States)

    de Oliveira, Adriana Kosma Pires; Hamerschmidt, Rogerio; Mocelin, Marcos; Rezende, Rodrigo K

    2012-07-01

     Dandy Walker Syndrome is a congenital abnormality in the central nervous system, characterized by a deficiency in the development of middle cerebelar structures, cystic dilatation of the posterior pit communicating with the fourth ventricle and upward shift of the transverse sinuses, tentorium and dyes. Among the clinical signs are occipital protuberances, a progressive increase of the skull, bowing before the fontanels, papilledema, ataxia, gait disturbances, nystagmus, and intellectual impairment.  To describe a case of female patient, 13 years old with a diagnosis of this syndrome and bilateral hearing loss underwent cochlear implant surgery under local anesthesia and sedation.  CGS, 13 years old female was referred to the Otolaryngological Department of Otolaryngology Institute of Parana with a diagnosis of "Dandy-Walker syndrome" for Otolaryngological evaluation for bilateral hearing loss with no response to the use of hearing aids. Final Comments: The field of cochlear implants is growing rapidly. We believe that the presence of Dandy-Walker syndrome cannot be considered a contraindication to the performance of cochlear implant surgery, and there were no surgical complications due to neurological disorders with very favorable results for the patient who exhibits excellent discrimination. It has less need for lip reading with improvement in speech quality.

  15. Cochlear implantation in patient with Dandy-walker syndrome

    Directory of Open Access Journals (Sweden)

    Oliveira, Adriana Kosma Pires de

    2012-01-01

    Full Text Available Introduction: Dandy Walker Syndrome is a congenital abnormality in the central nervous system, characterized by a deficiency in the development of middle cerebelar structures, cystic dilatation of the posterior pit communicating with the fourth ventricle and upward shift of the transverse sinuses, tentorium and dyes. Among the clinical signs are occipital protuberances, a progressive increase of the skull, bowing before the fontanels, papilledema, ataxia, gait disturbances, nystagmus, and intellectual impairment. Objectives: To describe a case of female patient, 13 years old with a diagnosis of this syndrome and bilateral hearing loss underwent cochlear implant surgery under local anesthesia and sedation. Case Report: CGS, 13 years old female was referred to the Otolaryngological Department of Otolaryngology Institute of Parana with a diagnosis of "Dandy-Walker syndrome" for Otolaryngological evaluation for bilateral hearing loss with no response to the use of hearing aids. Final Comments: The field of cochlear implants is growing rapidly. We believe that the presence of Dandy-Walker syndrome cannot be considered a contraindication to the performance of cochlear implant surgery, and there were no surgical complications due to neurological disorders with very favorable results for the patient who exhibits excellent discrimination. It has less need for lip reading with improvement in speech quality.

  16. Challenging aspects of contemporary cochlear implant electrode array design.

    Science.gov (United States)

    Mistrík, Pavel; Jolly, Claude; Sieber, Daniel; Hochmair, Ingeborg

    2017-12-01

    A design comparison of current perimodiolar and lateral wall electrode arrays of the cochlear implant (CI) is provided. The focus is on functional features such as acoustic frequency coverage and tonotopic mapping, battery consumption and dynamic range. A traumacity of their insertion is also evaluated. Review of up-to-date literature. Perimodiolar electrode arrays are positioned in the basal turn of the cochlea near the modiolus. They are designed to initiate the action potential in the proximity to the neural soma located in spiral ganglion. On the other hand, lateral wall electrode arrays can be inserted deeper inside the cochlea, as they are located along the lateral wall and such insertion trajectory is less traumatic. This class of arrays targets primarily surviving neural peripheral processes. Due to their larger insertion depth, lateral wall arrays can deliver lower acoustic frequencies in manner better corresponding to cochlear tonotopicity. In fact, spiral ganglion sections containing auditory nerve fibres tuned to low acoustic frequencies are located deeper than 1 and half turn inside the cochlea. For this reason, a significant frequency mismatch might be occurring for apical electrodes in perimodiolar arrays, detrimental to speech perception. Tonal languages such as Mandarin might be therefore better treated with lateral wall arrays. On the other hand, closer proximity to target tissue results in lower psychophysical threshold levels for perimodiolar arrays. However, the maximal comfort level is also lower, paradoxically resulting in narrower dynamic range than that of lateral wall arrays. Battery consumption is comparable for both types of arrays. Lateral wall arrays are less likely to cause trauma to cochlear structures. As the current trend in cochlear implantation is the maximal protection of residual acoustic hearing, the lateral wall arrays seem more suitable for hearing preservation CI surgeries. Future development could focus on combining the

  17. Complications Requiring Cochlear Reimplantation

    Directory of Open Access Journals (Sweden)

    Seied Basir Hashemi

    2011-01-01

    Conclusion:  In view of the fact that a significant proportion of the patients who complained of otalgia had no pathologies in the ear, thorough physical examination in adjacent structures especially teeth should be performed and malignancies should be considered as a possible etiology of otalgia.

  18. Handbook of radiologic procedures

    International Nuclear Information System (INIS)

    Hedgcock, M.

    1986-01-01

    This book is organized around radiologic procedures with each discussed from the points of view of: indications, contraindications, materials, method of procedures and complications. Covered in this book are: emergency radiology chest radiology, bone radiology, gastrointestinal radiology, GU radiology, pediatric radiology, computerized tomography, neuroradiology, visceral and peripheral angiography, cardiovascular radiology, nuclear medicine, lymphangiography, and mammography

  19. Prevention and management of cochlear implant infections.

    Science.gov (United States)

    Gluth, Michael B; Singh, Rajesh; Atlas, Marcus D

    2011-11-01

    Understanding the issues of infection related to an implantable medical device is crucial to all cochlear implant teams. Furthermore, given the risk of central nervous system complications and the relatively high quantity of underlying resource investment associated with cochlear implantation, the stakes of infection are high. The optimal strategies to prevent and manage such infections are still evolving as good-quality prospective data to guide such management decisions are not yet abundant within the medical literature and many recommendations are based on retrospective reviews or anecdotal evidence. We will outline a general strategy to deal with cochlear implant-related infection based on both the authors' experience and the published literature.

  20. Is All Human Hearing Cochlear?

    Directory of Open Access Journals (Sweden)

    Seyede Faranak Emami

    2013-01-01

    Full Text Available The objective of this cross-sectional study was to investigate the possibility that the saccule may contribute to human hearing. The forty participants included twenty healthy people and twenty other subjects selected from patients who presented with benign paroxysmal positional vertigo to Audiology Department of Hazrat Rasoul Akram hospital (Tehran, Iran. Assessments comprised of audiological evaluations, cervical vestibular evoked myogenic potentials (cVEMPs, recognition of spoken phonemes in white noise (Rsp in wn, and auditory brainstem response to 500 Hz tone burst (ABR500 HZ. Twenty affected ears with decreased vestibular excitability as detected by abnormal cVEMPs revealed decreased scores of Rsp in wn and abnormal findings of ABR500 HZ. Both unaffected and normal ears had normal results. Multiple comparisons of mean values of cVEMPs and ABR500 HZ between three groups were significant (P<0.05, ANOVA. The correlation between RSP in wn and p13 latencies was significant. The peak-to-peak amplitudes showed significant correlation to RSP in wn. The correlation between RSP in wn and the latencies of n23 was significant. In high-level of noisy competing situations, healthy human saccular sensation can mediate the detection of low frequencies and possibly help in cochlear hearing for frequency and intensity discrimination. So, all human hearing is not cochlear.

  1. A new computed tomography method to identify meningitis-related cochlear ossification and fibrosis before cochlear implantation.

    Science.gov (United States)

    Ichikawa, Kazunori; Kashio, Akinori; Mori, Harushi; Ochi, Atushi; Karino, Shotaro; Sakamoto, Takashi; Kakigi, Akinobu; Yamasoba, Tatsuya

    2014-04-01

    To develop a new method to determine the presence of intracochlear ossification and/or fibrosis in cochlear implantation candidates with bilateral profound deafness following meningitis. Diagnostic test assessment. A university hospital. This study involved 15 ears from 13 patients with profound deafness following meningitis who underwent cochlear implantation. These ears showed normal structures, soft tissue, partial bony occlusion, and complete bony occlusion in 4, 3, 2, and 6 ears, respectively. We measured radiodensity in Hounsfield units (HU) using 0.5-mm-thick axial high-resolution computed tomography image slices at 3 different levels in the basal turn, the fenestration, and inferior and ascending segment sites, located along the electrode-insertion path. Pixel-level analysis on the DICOM viewer yielded actual computed tomography values of intracochlear soft tissues by eliminating the partial volume effect. The values were compared with the intraoperative findings. Values for ossification (n = 12) ranged from +547 HU to +1137 HU; for fibrosis (n = 11), from +154 HU to +574 HU; and for fluid (n = 22), from -49 HU to +255 HU. From these values, we developed 2 presets of window width (WW) and window level (WL): (1) WW: 1800, WL: 1100 (200 HU to 2000 HU) and (2) WW: 1500, WL: 1250 (500 HU to 2000 HU). The results using these 2 presets corresponded well to the intraoperative findings. Our new method is easy and feasible for preoperative determination of the presence of cochlear ossification and/or fibrosis that develops following meningitis.

  2. Selective deletion of cochlear hair cells causes rapid age-dependent changes in spiral ganglion and cochlear nucleus neurons.

    Science.gov (United States)

    Tong, Ling; Strong, Melissa K; Kaur, Tejbeer; Juiz, Jose M; Oesterle, Elizabeth C; Hume, Clifford; Warchol, Mark E; Palmiter, Richard D; Rubel, Edwin W

    2015-05-20

    During nervous system development, critical periods are usually defined as early periods during which manipulations dramatically change neuronal structure or function, whereas the same manipulations in mature animals have little or no effect on the same property. Neurons in the ventral cochlear nucleus (CN) are dependent on excitatory afferent input for survival during a critical period of development. Cochlear removal in young mammals and birds results in rapid death of target neurons in the CN. Cochlear removal in older animals results in little or no neuron death. However, the extent to which hair-cell-specific afferent activity prevents neuronal death in the neonatal brain is unknown. We further explore this phenomenon using a new mouse model that allows temporal control of cochlear hair cell deletion. Hair cells express the human diphtheria toxin (DT) receptor behind the Pou4f3 promoter. Injections of DT resulted in nearly complete loss of organ of Corti hair cells within 1 week of injection regardless of the age of injection. Injection of DT did not influence surrounding supporting cells directly in the sensory epithelium or spiral ganglion neurons (SGNs). Loss of hair cells in neonates resulted in rapid and profound neuronal loss in the ventral CN, but not when hair cells were eliminated at a more mature age. In addition, normal survival of SGNs was dependent on hair cell integrity early in development and less so in mature animals. This defines a previously undocumented critical period for SGN survival. Copyright © 2015 the authors 0270-6474/15/357878-14$15.00/0.

  3. Radiological optimization

    International Nuclear Information System (INIS)

    Zeevaert, T.

    1998-01-01

    Radiological optimization is one of the basic principles in each radiation-protection system and it is a basic requirement in the safety standards for radiation protection in the European Communities. The objectives of the research, performed in this field at the Belgian Nuclear Research Centre SCK-CEN, are: (1) to implement the ALARA principles in activities with radiological consequences; (2) to develop methodologies for optimization techniques in decision-aiding; (3) to optimize radiological assessment models by validation and intercomparison; (4) to improve methods to assess in real time the radiological hazards in the environment in case of an accident; (5) to develop methods and programmes to assist decision-makers during a nuclear emergency; (6) to support the policy of radioactive waste management authorities in the field of radiation protection; (7) to investigate existing software programmes in the domain of multi criteria analysis. The main achievements for 1997 are given

  4. MEMO radiology

    International Nuclear Information System (INIS)

    Wagner-Manslau, C.

    1989-01-01

    This radiology volume is a concise handbook of imaging techniques, nuclear medicine, and radiation therapy, albeit that the main emphasis is on classic radiology. It offers, for instance, a survey of radiological findings for the most frequent pathological conditions, many overviews of differential diagnosis, a glossary of the technical bases of radiology and so forth. The contents are divided into the following chapters: Physical and biological bases; skeleton; thorax with the subdivisions lungs, heart, mediastinum, and pleura; gastrointestinal tract with the subsections esophagus, small and large intestine; liver; biliary tract; pancreas; retroperitoneal space; kidney; suprarenal glands; bladder; blood vessels, lymph nodes, spleen; mammary glands; female genitals; prostate and scrotum, epididymis and seminal vesicle. (orig./MG) With 23 figs [de

  5. Diagnostic and interventional radiology

    Energy Technology Data Exchange (ETDEWEB)

    Vogl, Thomas J. [Klinikum der Johann Wolfgang Goethe-Universitaet, Frankfurt am Main (Germany). Inst. fuer Diagnostische und Interventionelle Radiologie; Reith, Wolfgang [Universitaetsklinikum des Saarlandes, Homburg/Saar (Germany). Klinik fuer Diagnostische und Interventionelle Neuroradiologie; Rummeny, Ernst J. (ed.) [Technische Univ. Muenchen Klinikum rechts der Isar, Muenchen (Germany). Inst. fuer Radiologie

    2016-08-01

    This exceptional book covers all aspects of diagnostic and interventional radiology within one volume, at a level appropriate for the specialist. From the basics through diagnosis to intervention: the reader will find a complete overview of all areas of radiology. The clear, uniform structure, with chapters organized according to organ system, facilitates the rapid retrieval of information. Features include: Presentation of the normal radiological anatomy Classification of the different imaging procedures according to their diagnostic relevance Imaging diagnosis with many reference images Precise description of the interventional options The inclusion of many instructive aids will be of particular value to novices in decision making: Important take home messages and summaries of key radiological findings smooth the path through the jungle of facts Numerous tables on differential diagnosis and typical findings in the most common diseases offer a rapid overview and orientation Diagnostic flow charts outline the sequence of diagnostic evaluation All standard procedures within the field of interventional radiology are presented in a clinically relevant and readily understandable way, with an abundance of illustrations. This is a textbook, atlas, and reference in one: with more than 2500 images for comparison with the reader's own findings. This comprehensive and totally up-to-date book provides a superb overview of everything that the radiology specialist of today needs to know.

  6. Cochlear implant: what the radiologist should know

    International Nuclear Information System (INIS)

    Gomes, Natalia Delage; Couto, Caroline Laurita Batista; Gaiotti, Juliana Oggioni; Costa, Ana Maria Doffemond; Ribeiro, Marcelo Almeida; Diniz, Renata Lopes Furletti Caldeira

    2013-01-01

    Cochlear implant is the method of choice in the treatment of deep sensorineural hypoacusis, particularly in patients where conventional amplification devices do not imply noticeable clinical improvement. Imaging findings are crucial in the indication or contraindication for such surgical procedure. In the assessment of the temporal bone, radiologists should be familiar with relative or absolute contraindication factors, as well as with factors that might significantly complicate the implantation. Some criteria such as cochlear nerve aplasia, labyrinthine and/or cochlear aplasia are still considered as absolute contraindications, in spite of studies bringing such criteria into question. Cochlear dysplasias constitute relative contraindications, among them labyrinthitis ossificans is highlighted. Other alterations may be mentioned as complicating agents in the temporal bone assessment, namely, hypoplasia of the mastoid process, aberrant facial nerve, otomastoiditis, otosclerosis, dehiscent jugular bulb, enlarged endolymphatic duct and sac. The experienced radiologist assumes an important role in the evaluation of this condition. (author)

  7. Cochlear implant: what the radiologist should know

    Directory of Open Access Journals (Sweden)

    Natalia Delage Gomes

    2013-06-01

    Full Text Available Cochlear implant is the method of choice in the treatment of deep sensorineural hypoacusis, particularly in patients where conventional amplification devices do not imply noticeable clinical improvement. Imaging findings are crucial in the indication or contraindication for such surgical procedure. In the assessment of the temporal bone, radiologists should be familiar with relative or absolute contraindication factors, as well as with factors that might significantly complicate the implantation. Some criteria such as cochlear nerve aplasia, labyrinthine and/or cochlear aplasia are still considered as absolute contraindications, in spite of studies bringing such criteria into question. Cochlear dysplasias constitute relative contraindications, among them labyrinthitis ossificans is highlighted. Other alterations may be mentioned as complicating agents in the temporal bone assessment, namely, hypoplasia of the mastoid process, aberrant facial nerve, otomastoiditis, otosclerosis, dehiscent jugular bulb, enlarged endolymphatic duct and sac. The experienced radiologist assumes an important role in the evaluation of this condition.

  8. Cochlear anatomy: CT and MR imaging

    International Nuclear Information System (INIS)

    Martinez, Manuel; Bruno, Claudio; Martin, Eduardo; Canale, Nancy; De Luca, Laura; Spina, Juan C. h

    2002-01-01

    The authors present a brief overview of the normal cochlear anatomy with CT and MR images in order to allow a more complete identification of the pathological findings in patients with perceptive hipoacusia. (author)

  9. Radiological hazards

    International Nuclear Information System (INIS)

    Hamilton, M.

    1984-01-01

    The work of the (United Kingdom) National Radiological Protection Board is discussed. The following topics are mentioned: relative contributions to genetically significant doses of radiation from various sources; radon gas in non-coal mines and in dwelling houses; effects of radiation accidents; radioactive waste disposal; radiological protection of the patient in medicine; microwaves, infrared radiation and cataracts; guidance notes for use with forthcoming Ionising Radiations Regulations; training courses; personal dosimetry service; work related to European Communities. (U.K.)

  10. Intracochlear pressure measurements in scala media inform models of cochlear mechanics

    Science.gov (United States)

    Kale, Sushrut; Olson, Elizabeth S.

    2015-12-01

    In the classic view of cochlear mechanics, the cochlea is comprised of two identical fluid chambers separated by the cochlear partition (CP). In this view the traveling wave pressures in the two chambers mirror each other; they are equal in magnitude and opposite in phase. A fast pressure mode adds approximately uniformly. More recent models of cochlear mechanics take into account the structural complexity of the CP and the resulting additional mechanical modes would lead to distinct (non-symmetric) patterns of pressure and motion on the two sides of the CP. However, there was little to no physiological data that explored these predictions. To this aim, we measured intracochlear fluid pressure in scala media (SM), including measurements close to the sensory tissue, using miniaturized pressure sensors (˜ 80 μm outer diameter). Measurements were made in-vivo from the basal cochlear turn in gerbils. SM pressure was measured at two longitudinal locations in different preparations. In a subset of the experiments SM and ST (scala tympani) pressures were measured at the same longitudinal location. Traveling wave pressures were observed in both SM and ST, and showed the relative phase predicted by the classical theory. In addition, SM pressure showed spatial variations that had not been observed in ST, which points to a relatively complex CP motion on the SM side. These data both underscore the first-order validity of the classic cochlear traveling wave model, and open a new view to CP mechanics.

  11. Breaking the sound barrier: exploring parents' decision-making process of cochlear implants for their children.

    Science.gov (United States)

    Chang, Pamara F

    2017-08-01

    To understand the dynamic experiences of parents undergoing the decision-making process regarding cochlear implants for their child(ren). Thirty-three parents of d/Deaf children participated in semi-structured interviews. Interviews were digitally recorded, transcribed, and coded using iterative and thematic coding. The results from this study reveal four salient topics related to parents' decision-making process regarding cochlear implantation: 1) factors parents considered when making the decision to get the cochlear implant for their child (e.g., desire to acculturate child into one community), 2) the extent to which parents' communities influence their decision-making (e.g., norms), 3) information sources parents seek and value when decision-making (e.g., parents value other parent's experiences the most compared to medical or online sources), and 4) personal experiences with stigma affecting their decision to not get the cochlear implant for their child. This study provides insights into values and perspectives that can be utilized to improve informed decision-making, when making risky medical decisions with long-term implications. With thorough information provisions, delineation of addressing parents' concerns and encompassing all aspects of the decision (i.e., medical, social and cultural), health professional teams could reduce the uncertainty and anxiety for parents in this decision-making process for cochlear implantation. Copyright © 2017 Elsevier B.V. All rights reserved.

  12. Parametric model of the scala tympani for haptic-rendered cochlear implantation.

    Science.gov (United States)

    Todd, Catherine; Naghdy, Fazel

    2005-01-01

    A parametric model of the human scala tympani has been designed for use in a haptic-rendered computer simulation of cochlear implant surgery. It will be the first surgical simulator of this kind. A geometric model of the Scala Tympani has been derived from measured data for this purpose. The model is compared with two existing descriptions of the cochlear spiral. A first approximation of the basilar membrane is also produced. The structures are imported into a force-rendering software application for system development.

  13. Cortical Plasticity after Cochlear Implantation

    DEFF Research Database (Denmark)

    Petersen, Bjørn; Gjedde, Albert; Wallentin, Mikkel

    2013-01-01

    recently implanted adult implant recipients listened to running speech or speech-like noise in four sequential PET sessions at each milestone. CI listeners with postlingual hearing loss showed differential activation of left superior temporal gyrus during speech and speech-like stimuli, unlike CI listeners...... with prelingual hearing loss. Furthermore, Broca's area was activated as an effect of time, but only in CI listeners with postlingual hearing loss. The study demonstrates that adaptation to the cochlear implant is highly related to the history of hearing loss. Speech processing in patients whose hearing loss...... occurred after the acquisition of language involves brain areas associated with speech comprehension, which is not the case for patients whose hearing loss occurred before the acquisition of language. Finally, the findings confirm the key role of Broca's area in restoration of speech perception, but only...

  14. Music enjoyment with cochlear implantation.

    Science.gov (United States)

    Prevoteau, Charlotte; Chen, Stephanie Y; Lalwani, Anil K

    2018-10-01

    Since the advent of cochlear implant (CI) surgery in the 1960s, there have been remarkable technological and surgical advances enabling excellent speech perception in quiet with many CI users able to use the telephone. However, many CI users struggle with music perception, particularly with the pitch-based and melodic elements of music. Yet remarkably, despite poor music perception, many CI users enjoy listening to music based on self-report questionnaires, and prospective studies have suggested a disassociation between music perception and enjoyment. Music enjoyment is arguably a more functional measure of one's listening experience, and thus enhancing one's listening experience is a worthy goal. Recent studies have shown that re-engineering music to reduce its complexity may enhance enjoyment in CI users and also delineate differences in musical preferences from normal hearing listeners. Copyright © 2017 Elsevier B.V. All rights reserved.

  15. The Human Cochlear Mechanical Nonlinearity Inferred via Psychometric Functions

    Directory of Open Access Journals (Sweden)

    Nizami Lance

    2013-12-01

    Extension of the model of Schairer and colleagues results in credible cochlear nonlinearities in man, suggesting that forward-masking provides a non-invasive way to infer the human mechanical cochlear nonlinearity.

  16. Radiological protection

    International Nuclear Information System (INIS)

    Azorin N, J.; Azorin V, J. C.

    2010-01-01

    This work is directed to all those people related with the exercise of the radiological protection and has the purpose of providing them a base of knowledge in this discipline so that they can make decisions documented on technical and scientist factors for the protection of the personnel occupationally exposed, the people in general and the environment during the work with ionizing radiations. Before de lack of a text on this matter, this work seeks to cover the specific necessities of our country, providing a solid presentation of the radiological protection, included the bases of the radiations physics, the detection and radiation dosimetry, the radiobiology, the normative and operational procedures associates, the radioactive wastes, the emergencies and the transport of the radioactive material through the medical and industrial applications of the radiations, making emphasis in the relative particular aspects to the radiological protection in Mexico. The book have 16 chapters and with the purpose of supplementing the given information, are included at the end four appendixes: 1) the radioactive waste management in Mexico, 2-3) the Mexican official standards related with the radiological protection, 4) a terms glossary used in radiological protection. We hope this book will be of utility for those people that work in the investigation and the applications of the ionizing radiations. (Author)

  17. Technological and operational structure of the National Automatic Network for Environmental Radiological Monitoring (RENAMORA); Estructura tecnologica y operativa de la Red Nacional Automatica de Monitoreo Radiologico Ambiental RENAMORA

    Energy Technology Data Exchange (ETDEWEB)

    Martinez G, E.; Lopez G, M.; Aguirre G, J.; Fabian O, R.; Hernandez A, Y., E-mail: elias.martinez@cnsns.gob.mx [Comision Nacional de Seguridad Nuclear y Salvaguardias, Dr. Barragan 779, Col. Narvarte, 03020 Ciudad de Mexico (Mexico)

    2015-09-15

    The Comision Nacional de Seguridad Nuclear y Salvaguardias (CNSNS) in Mexico is a decentralized body, under the Secretaria de Energia whose main mission is to ensure that activities involving nuclear and radioactive materials as well as ionizing radiation sources are carried out with maximum security, considering the current technological developments. In order to monitor the levels of environmental radiation to which the population is exposed, the CNSNS has established a series of radiological monitoring programs that allow characterize the environmental radiation levels in each zone or region in the country; to identify the occurrence of natural or artificial radiological events, such as nuclear tests and accidents in radioactive or nuclear facilities. The National Automatic Network for Environmental Radiological Monitoring (RENAMORA) project was initiated with the support of the IAEA through MEX9/049 project and its purpose is to have a network of instruments that automatically and in real time, transmit information of the gamma radiological environmental status of the national territory and changes occurring in it. This network provides data such as the speed of ambient dose equivalent, temperature and humidity in different regions of the country. The network is composed of 92 stations that are distributed throughout the national territory. The structure of the stations has evolved since its inception, now allowing detection tasks, data transmission and managing them remotely from the main server, which is located in the CNSNS, which is performed a statistical dose for each monitoring station. Each monitoring station is formed in its current structure by a probe detection of gamma radiation, a communication module and associated electronics, a mini Web server DataGATE, a cellular modem and an interface converter. (Author)

  18. White Paper: Curriculum in Interventional Radiology.

    Science.gov (United States)

    Mahnken, Andreas H; Bücker, Arno; Hohl, Christian; Berlis, Ansgar

    2017-04-01

    Purpose  Scope and clinical importance of interventional radiology markedly evolved over the last decades. Consequently it was acknowledged as independent subspecialty by the "European Union of Medical Specialists" (UEMS). Based on radiological imaging techniques Interventional Radiology is an integral part of Radiology. Materials und Methods  In 2009 the German Society for Interventional Radiology and minimally-invasive therapy (DeGIR) developed a structured training in Interventional Radiology. In cooperation with the German Society of Neuroradiology (DGNR) this training was extended to also cover Interventional Neuroradiology in 2012. Tailored for this training in Interventional Radiology a structured curriculum was developed, covering the scope of this modular training. Results  The curriculum is based on the DeGIR/DGNR modular training concept in Interventional Radiology. There is also an European Curriculum and Syllabus for Interventional Radiology developed by the "Cardiovascular and Interventional Radiological Society of Europe" (CIRSE). The presented curriculum in Interventional Radiology is designed to provide a uniform base for the training in Interventional Radiology in Germany, based on the competencies obtained during residency. Conclusion  This curriculum can be used as a basis for training in Interventional Radiology by all training sites. Key Points: · Interventional Radiology is an integral part of clinical radiology. · The German Society for Interventional Radiology and minimally-invasive therapy (DeGIR) developed a curriculum in Interventional Radiology. · This curriculum is an integrative basis for the training in interventional. Citation Format · Mahnken AH, Bücker A, Hohl C et al. White Paper: Curriculum in Interventional Radiology. Fortschr Röntgenstr 2017; 189: 309 - 311. © Georg Thieme Verlag KG Stuttgart · New York.

  19. The structure and peculiarities of lung involvement in children and teenagers with lupus erythematosus according to radiological studies

    International Nuclear Information System (INIS)

    Churilyin, R.Yu.

    2004-01-01

    The state of the lungs, pleura, diaphragm and heart in children (36 patients) with lupus erythematosus using radiological studies was defined. The study allowed to work out the scheme of main morphofunctional, x-ray, and ultrasound changes in the respiratory and cardiovascular systems

  20. Migration of cochlear lateral wall cells.

    Science.gov (United States)

    Dunaway, George; Mhaskar, Yashanad; Armour, Gary; Whitworth, Craig; Rybak, Leonard

    2003-03-01

    The role of apoptosis and proliferation in maintenance of cochlear lateral wall cells was examined. The methods employed for detection of apoptosis were the Hoechst fluorescence stain and TUNEL (TdT-mediated dUTP-biotin nick-end-labeling) assay, and proliferations were 5-bromo-2'-deoxyuridine (BrdU) incorporation and presence of the proliferating cell nuclear antigen. The incidence of apoptosis in the strial marginal cell was 50% greater (32.9+/-3.7%) than strial intermediate and basal cells but similar to spiral ligament cells. Although division of marginal strial cells was rarely detected, a significant number of proliferating cells in the remaining stria vascularis and spiral ligament were observed. These data implied that replacement of marginal cells arose elsewhere and could be followed by a BrdU-deoxythymidine pulse-chase study. At 2 h post injection, nuclear BrdU in marginal cells was not detected; however, by 24 h post injection, 20-25% of marginal cell nuclei were BrdU-positive. These observations are consistent with the hypothesis that marginal cells were replaced by underlying cells. Cell migration appears to be an important mechanism for preserving the function and structure of the stria vascularis.

  1. Radionuclide radiology

    International Nuclear Information System (INIS)

    Scarsbrook, A.F.; Graham, R.N.J.; Perriss, R.W.; Bradley, K.M.

    2006-01-01

    This is the fourth in a series of short reviews of internet-based radiological educational resources, and will focus on radionuclide radiology and nuclear medicine. What follows is a list of carefully selected websites to save time in searching them out. Most of the sites cater for trainee or non-specialist radiologists, but may also be of interest to specialists for use in teaching. This article may be particularly useful to radiologists interested in the rapidly expanding field of positron emission tomography computed tomography (PET-CT). Hyperlinks are available in the electronic version of this article and were all active at the time of going to press (February 2006)

  2. Emergency radiology

    International Nuclear Information System (INIS)

    Keats, T.E.

    1986-01-01

    This book is the German, translated version of the original published in 1984 in the U.S.A., entitled 'Emergency Radiology'. The publication for the most part is made up as an atlas of the radiological images presenting the findings required for assessment of the emergency cases and their first treatment. The test parts' function is to explain the images and give the necessary information. The material is arranged in seven sections dealing with the skull, the facial part of the skull, the spine, thorax, abdominal region, the pelvis and the hip, and the limbs. With 690 figs [de

  3. Postoperative radiology

    International Nuclear Information System (INIS)

    Burhenne, H.J.

    1989-01-01

    This paper reports on the importance of postoperative radiology. Most surgical procedures on the alimentary tract are successful, but postoperative complications remain a common occurrence. The radiologist must be familiar with a large variety of possible surgical complications, because it is this specialty that is most commonly called on to render a definitive diagnosis. The decision for reoperation, for instance, is usually based on results from radiologic imaging techniques. These now include ultrasonography, CT scanning, needle biopsy, and interventional techniques in addition to contrast studies and nuclear medicine investigation

  4. Radiology of chest diseases

    International Nuclear Information System (INIS)

    Lange, S.; Stark, P.

    1990-01-01

    This book is divided into three parts: The first part - 'Technology and normal findings' - explains current radiological diagnostic methods. The indications for particular examinations are given, with the techniques and possible errors. The second part of the book - 'Diseases of the lung' - gives a systematic description of basic knowledge needed for diagnosis. Each chapter begins with a definition of the disease and a discussion of the diagnostic information that can be expected from the various radiological methods. This is followed by the pathological morphology and pathological physiology and the clinical symptoms. The third part of the book - 'Radiological signs and differential diagnosis' - deals with image patterns, such as segmental opacities, calcification, localized hyperlucency, etc. It begins where the diagnostician must begin - immediate confrontation with the radiograph, analysis of the details, recognition of structures and understanding the image. (orig./DGD) With 381 figs., 42 tabs

  5. Recognition of "real-world" musical excerpts by cochlear implant recipients and normal-hearing adults.

    Science.gov (United States)

    Gfeller, Kate; Olszewski, Carol; Rychener, Marly; Sena, Kimberly; Knutson, John F; Witt, Shelley; Macpherson, Beth

    2005-06-01

    The purposes of this study were (a) to compare recognition of "real-world" music excerpts by postlingually deafened adults using cochlear implants and normal-hearing adults; (b) to compare the performance of cochlear implant recipients using different devices and processing strategies; and (c) to examine the variability among implant recipients in recognition of musical selections in relation to performance on speech perception tests, performance on cognitive tests, and demographic variables. Seventy-nine cochlear implant users and 30 normal-hearing adults were tested on open-set recognition of systematically selected excerpts from musical recordings heard in real life. The recognition accuracy of the two groups was compared for three musical genre: classical, country, and pop. Recognition accuracy was correlated with speech recognition scores, cognitive measures, and demographic measures, including musical background. Cochlear implant recipients were significantly less accurate in recognition of previously familiar (known before hearing loss) musical excerpts than normal-hearing adults (p genre. Implant recipients were most accurate in the recognition of country items and least accurate in the recognition of classical items. There were no significant differences among implant recipients due to implant type (Nucleus, Clarion, or Ineraid), or programming strategy (SPEAK, CIS, or ACE). For cochlear implant recipients, correlations between melody recognition and other measures were moderate to weak in strength; those with statistically significant correlations included age at time of testing (negatively correlated), performance on selected speech perception tests, and the amount of focused music listening following implantation. Current-day cochlear implants are not effective in transmitting several key structural features (i.e., pitch, harmony, timbral blends) of music essential to open-set recognition of well-known musical selections. Consequently, implant

  6. Retrolabyrinthine approach for cochlear nerve preservation in neurofibromatosis type 2 and simultaneous cochlear implantation

    Directory of Open Access Journals (Sweden)

    Bento, Ricardo Ferreira

    2014-01-01

    Full Text Available Introduction: Few cases of cochlear implantation (CI in neurofibromatosis type 2 (NF2 patients had been reported in the literature. The approaches described were translabyrinthine, retrosigmoid or middle cranial fossa. Objectives: To describe a case of a NF2- deafened-patient who underwent to vestibular schwannoma resection via RLA with cochlear nerve preservation and CI through the round window, at the same surgical time. Resumed Report: A 36-year-old woman with severe bilateral hearing loss due to NF2 was submitted to vestibular schwannoma resection and simultaneous CI. Functional assessment of cochlear nerve was performed by electrical promontory stimulation. Complete tumor removal was accomplishment via RLA with anatomic and functional cochlear and facial nerve preservation. Cochlear electrode array was partially inserted via round window. Sound field hearing threshold improvement was achieved. Mean tonal threshold was 46.2 dB HL. The patient could only detect environmental sounds and human voice but cannot discriminate vowels, words nor do sentences at 2 years of follow-up. Conclusion: Cochlear implantation is a feasible auditory restoration option in NF2 when cochlear anatomic and functional nerve preservation is achieved. The RLA is adequate for this purpose and features as an option for hearing preservation in NF2 patients.

  7. Radiological protection in interventional radiology

    International Nuclear Information System (INIS)

    Padovani, R.

    2001-01-01

    Interventional radiology (IR) reduces the need for many traditional interventions, particularly surgery, so reducing the discomfort and risk for patients compared with traditional systems. IR procedures are frequently performed by non-radiologist physicians, often without the proper radiological equipment and sufficient knowledge of radiation protection. Levels of doses to patients and staff in IR vary enormously. A poor correlation exists between patient and staff dose, and large variations of dose are reported for the same procedure. The occurrence of deterministic effects in patients is another peculiar aspect of IR owing to the potentially high skin doses of some procedures. The paper reviews the use of IR and the radiological protection of patients and staff, and examines the need for new standards for IR equipment and the training of personnel. (author)

  8. The cochlear implant as a tinnitus treatment.

    Science.gov (United States)

    Vallés-Varela, Héctor; Royo-López, Juan; Carmen-Sampériz, Luis; Sebastián-Cortés, José M; Alfonso-Collado, Ignacio

    2013-01-01

    Tinnitus is a symptom of high prevalence in patients with cochlear pathology. We studied the evolution of tinnitus in patients undergoing unilateral cochlear implantation for treatment of profound hearing loss. This was a longitudinal, retrospective study of patients that underwent unilateral cochlear implantation and who had bilateral tinnitus. Tinnitus was assessed quantitatively and qualitatively before surgery and at 6 and 12 months after surgery. We evaluated 20 patients that underwent unilateral cochlear implantation with a Nucleus(®) CI24RE Contour Advance™ electrode device. During the periods in which the device was in operation, improvement or disappearance of tinnitus was evidenced in the ipsilateral ear in 65% of patients, and in the contralateral ear, in 50%. In periods in which the device was disconnected, improvement or disappearance of tinnitus was found in the ipsilateral ear in 50% of patients, and in the ear contralateral to the implant in 45% of the patients. In 10% of the patients, a new tinnitus appeared in the ipsilateral ear. The patients with profound hearing loss and bilateral tinnitus treated with unilateral cochlear implantation improved in a high percentage of cases, in the ipsilateral ear and in the contralateral ear. Copyright © 2012 Elsevier España, S.L. All rights reserved.

  9. Pediatric radiology

    International Nuclear Information System (INIS)

    Benz-Bohm, G.

    1997-01-01

    Pediatric radiology is an important subsection of diagnostic radiology involving specific difficulties, but unfortunately is quite too often neglected as a subject of further education and training. The book therefore is not intended for specialists in the field, but for radiologists wishing to plunge deeper into the matter of pediatric radiology and to acquire a sound, basic knowledge and information about well-proven modalities, the resulting diagnostic images, and interpretation of results. The book is a compact guide and a helpful source of reference and information required for every-day work, or in special cases. With patients who are babies or children, the challenges are different. The book offers all the information needed, including important experience from pediatric hospital units that may be helpful in diagnostic evaluation, information about specific dissimilarities in anatomy and physiology which affect the imaging results, hints for radiology planning and performance, as well as information about the various techniques and their indication and achievements. The book presents a wide spectrum of informative and annotated images. (orig./CB) [de

  10. Radiologic considerations

    International Nuclear Information System (INIS)

    Judge, L.O.

    1987-01-01

    An increasing variety of imaging modalities as well as refinements of interventional techniques have led to a resurgence of radiologic interest and participation in urolithiasis management. Judicious selection of the diagnostic examination, close monitoring during the procedure, consultation with urologic colleagues, and a careful regard for radiation safety guidelines define the role of the radiologist in renal stone disease

  11. Usher syndrome and cochlear implantation.

    Science.gov (United States)

    Loundon, Natalie; Marlin, Sandrine; Busquet, Denise; Denoyelle, Françoise; Roger, Gilles; Renaud, Francis; Garabedian, Erea Noel

    2003-03-01

    To evaluate the symptoms leading to diagnosis and the quality of rehabilitation after cochlear implantation in Usher syndrome. Retrospective cohort study. ENT department of a tertiary referral hospital. Among 210 patients given an implantation in the Ear, Nose, and Throat department, 185 were congenitally deaf and 13 had Usher syndrome (7.0%). Five had a family history of Usher, and eight were sporadic cases. Eleven cases were Usher type I, one was Usher type III, and one was not classified. The age at implantation ranged from 18 months to 44 years (mean, 6 years 1 month). The mean follow-up was 52 months (range, 9 months to 9 years). All patients had audiophonological and clinical examination, computed tomography scan of the temporal bones, ophthalmologic examination with fundoscopy, and an electroretinogram. Cerebral magnetic resonance imaging and vestibular examination were performed in 9 of 13 and 10 of 13 cases, respectively. Logopedic outcome measured preimplant and postimplant closed- and open-set word recognition and oral expression at follow-up. The most frequent initial sign of Usher syndrome was delayed walking, with a mean age of 20 months. Among the 172 other congenitally deaf children with implants, when deafness was not associated with other neurologic disorders, the mean age at walking was 14 months (p < 0.001). The fundoscopy was always abnormal after the age of 5 years, and the electroretinogram was abnormal in all cases. Vestibular function was abnormal in all but one case (nonclassified). The computed tomography scan and the magnetic resonance imaging were always normal. Logopedic results with cochlear implants showed good perception skills in all but one case. The best perceptive results were obtained in children implanted before the age of 9 years. Oral language had significantly progressed in 9 of 13 at follow-up. There was no relation between the visual acuity and the logopedic results. The earliest clinical sign associated with deafness

  12. Subcortical amplitude modulation encoding deficits suggest evidence of cochlear synaptopathy in normal-hearing 18-19 year olds with higher lifetime noise exposure.

    Science.gov (United States)

    Paul, Brandon T; Waheed, Sajal; Bruce, Ian C; Roberts, Larry E

    2017-11-01

    Noise exposure and aging can damage cochlear synapses required for suprathreshold listening, even when cochlear structures needed for hearing at threshold remain unaffected. To control for effects of aging, behavioral amplitude modulation (AM) detection and subcortical envelope following responses (EFRs) to AM tones in 25 age-restricted (18-19 years) participants with normal thresholds, but different self-reported noise exposure histories were studied. Participants with more noise exposure had smaller EFRs and tended to have poorer AM detection than less-exposed individuals. Simulations of the EFR using a well-established cochlear model were consistent with more synaptopathy in participants reporting greater noise exposure.

  13. Parental expectations and outcomes of pediatric cochlear implantation.

    Science.gov (United States)

    Piazza, Elizabeth; Kandathil, Cherian; Carron, Jeffrey D

    2009-10-01

    Cochlear implants have been used with increasing frequency over the past twenty years, including very young patients. To determine if parents are satisfied with their children's performance after cochlear implantation. Survey mailed to parents of children receiving cochlear implants. 31 questionnaires were returned out of 69 mailed (45 %). The vast majority of responding parents felt that their children benefited substantially from cochlear implant surgery. Cochlear implantation is effective in helping children develop auditory-oral communication skills. Access to auditory/oral communication programs in this state remains an obstacle in postoperative habilitation.

  14. Dual Coding of Frequency Modulation in the Ventral Cochlear Nucleus.

    Science.gov (United States)

    Paraouty, Nihaad; Stasiak, Arkadiusz; Lorenzi, Christian; Varnet, Léo; Winter, Ian M

    2018-04-25

    Frequency modulation (FM) is a common acoustic feature of natural sounds and is known to play a role in robust sound source recognition. Auditory neurons show precise stimulus-synchronized discharge patterns that may be used for the representation of low-rate FM. However, it remains unclear whether this representation is based on synchronization to slow temporal envelope (ENV) cues resulting from cochlear filtering or phase locking to faster temporal fine structure (TFS) cues. To investigate the plausibility of those encoding schemes, single units of the ventral cochlear nucleus of guinea pigs of either sex were recorded in response to sine FM tones centered at the unit's best frequency (BF). The results show that, in contrast to high-BF units, for modulation depths within the receptive field, low-BF units (modulation depths extending beyond the receptive field, the discharge patterns follow the ENV and fluctuate at the modulation rate. The receptive field proved to be a good predictor of the ENV responses for most primary-like and chopper units. The current in vivo data also reveal a high level of diversity in responses across unit types. TFS cues are mainly conveyed by low-frequency and primary-like units and ENV cues by chopper and onset units. The diversity of responses exhibited by cochlear nucleus neurons provides a neural basis for a dual-coding scheme of FM in the brainstem based on both ENV and TFS cues. SIGNIFICANCE STATEMENT Natural sounds, including speech, convey informative temporal modulations in frequency. Understanding how the auditory system represents those frequency modulations (FM) has important implications as robust sound source recognition depends crucially on the reception of low-rate FM cues. Here, we recorded 115 single-unit responses from the ventral cochlear nucleus in response to FM and provide the first physiological evidence of a dual-coding mechanism of FM via synchronization to temporal envelope cues and phase locking to temporal

  15. The nuclear medicine department in the emergency management plan: a referent structure for the nuclear and radiological risks

    International Nuclear Information System (INIS)

    Barat, J.L.; Ducassou, D.; Lesgourgues, P.; Zamaron, S.; Boulard, G.

    2006-01-01

    Each french public or private hospital has to establish guidelines for an immediate response to mass casualties (Emergency Management Plan or 'White' Plan). For a nuclear accident or terrorist attack, the staff of the Nuclear Medicine Department may be adequately prepared and equipped. This paper presents the nuclear and radiological risks section of the final draft of the White Plan developed at Bordeaux University Hospital. (author)

  16. Cochlear implant after bacterial meningitis.

    Science.gov (United States)

    Bille, Jesper; Ovesen, Therese

    2014-06-01

    The aim of this retrospective case study at a tertiary referral center was to investigate the outcome of cochlear implantation (CI) in children with sensorineural hearing loss due to meningitis compared to CI in children with deafness due to other reasons. This post-meningial group (PMG) consisted of 22 children undergoing CI due to deafness induced by meningitis, between December 1996 and January 2012. Five children had bilateral simultaneous implantation. None was excluded and the children were followed for at least 3 years. Operations were carried out by one of two surgeons using similar techniques in all cases. Each patient from the PMG was matched 2:1 with children having implantation for other reasons according to age and follow up (control group). Overall, the median category of auditory performance (CAP) and speech intelligibility rating (SIR) score were not statistically significantly different between the two groups. The presence of additional central nervous system (CNS) disorders (post-meningeal sequelae), however, correlated significantly with poorer outcome CI was a safe procedure without surgical complications in the present study. It is possible to restore auditory capacity and speech performance to a degree comparable to children undergoing implantation for other reasons. A statistically important variable is secondary CNS involvement. The rehabilitation program after CI should be adjusted according to these additional handicaps. It is recommended to screen meningitis patients as fast as possible to identify those with hearing loss and initiate treatment with hearing aids or CI. © 2013 The Authors. Pediatrics International © 2013 Japan Pediatric Society.

  17. Tinnitus and Sleep Difficulties After Cochlear Implantation.

    Science.gov (United States)

    Pierzycki, Robert H; Edmondson-Jones, Mark; Dawes, Piers; Munro, Kevin J; Moore, David R; Kitterick, Pádraig T

    To estimate and compare the prevalence of and associations between tinnitus and sleep difficulties in a sample of UK adult cochlear implant users and those identified as potential candidates for cochlear implantation. The study was conducted using the UK Biobank resource, a population-based cohort of 40- to 69-year olds. Self-report data on hearing, tinnitus, sleep difficulties, and demographic variables were collected from cochlear implant users (n = 194) and individuals identified as potential candidates for cochlear implantation (n = 211). These "candidates" were selected based on (i) impaired hearing sensitivity, inferred from self-reported hearing aid use and (ii) impaired hearing function, inferred from an inability to report words accurately at negative signal to noise ratios on an unaided closed-set test of speech perception. Data on tinnitus (presence, persistence, and related distress) and on sleep difficulties were analyzed using logistic regression models controlling for gender, age, deprivation, and neuroticism. The prevalence of tinnitus was similar among implant users (50%) and candidates (52%; p = 0.39). However, implant users were less likely to report that their tinnitus was distressing at its worst (41%) compared with candidates (63%; p = 0.02). The logistic regression model suggested that this difference between the two groups could be explained by the fact that tinnitus was less persistent in implant users (46%) compared with candidates (72%; p reported difficulties with sleep were similar among implant users (75%) and candidates (82%; p = 0.28), but participants with tinnitus were more likely to report sleep difficulties than those without (p explanation is supported by the similar prevalence of sleep problems among implant users and potential candidates for cochlear implantation, despite differences between the groups in tinnitus persistence and related emotional distress. Cochlear implantation may therefore not be an appropriate intervention

  18. Cytomegalovirus (CMV) Infection Causes Degeneration of Cochlear Vasculature and Hearing Loss in a Mouse Model.

    Science.gov (United States)

    Carraro, Mattia; Almishaal, Ali; Hillas, Elaine; Firpo, Matthew; Park, Albert; Harrison, Robert V

    2017-04-01

    Cytomegalovirus (CMV) infection is one of the most common causes of congenital hearing loss in children. We have used a murine model of CMV infection to reveal functional and structural cochlear pathogenesis. The cerebral cortex of Balb/c mice (Mus musculus) was inoculated with 2000 pfu (plaque forming units) of murine CMV on postnatal day 3. At 6 weeks of age, cochlear function was monitored using auditory brainstem response (ABR) and distortion product otoacoustic emission (DPOAE) measures. Histological assessment of cochlear vasculature using a corrosion cast technique was made at 8 weeks. Vascular casts of mCMV-damaged cochleas, and those of untreated control animals, were examined using scanning electron microscopy. We find very large variations in the degree of vascular damage in animals given identical viral injections (2000 pfu). The primary lesion caused by CMV infection is to the stria vascularis and to the adjacent spiral limbus capillary network. Capillary beds of the spiral ligament are generally less affected. The initial vascular damage is found in the mid-apical turn and appears to progress to more basal cochlear regions. After viral migration to the inner ear, the stria vascularis is the primary affected structure. We suggest that initial auditory threshold losses may relate to the poor development or maintenance of the endocochlear potential caused by strial dysfunction. Our increased understanding of the pathogenesis of CMV-related hearing loss is important for defining methods for early detection and treatment.

  19. Study of the Carrier-Aided Thin Film Electrode Array Design for Cochlear Insertion

    Directory of Open Access Journals (Sweden)

    Yuchen Xu

    2018-04-01

    Full Text Available The micro-fabricated thin film electrode array (TFEA has been a promising design for cochlear implants (CIs because of its cost-effectiveness and fabrication precision. The latest polymer-based cochlear TFEAs have faced difficulties for cochlear insertion due to the lack of structural stiffness. To stiffen the TFEA, dissolvable stiffening materials, TFEAs with different structures, and TFEAs with commercial CIs as carriers have been invested. In this work, the concept of enhancing a Parylene TFEA with Kapton tape as a simpler carrier for cochlear insertion has been proved to be feasible. The bending stiffness of the Kapton-aided TFEA was characterized with an analytical model, a finite element model, and a cantilever bending experiment, respectively. While the Kapton tape increased the bending stiffness of the Parylene TFEA by 103 times, the 6-μm-thick TFEA with a similar Young’s modulus, as a polyimide, in turn significantly increased the bending stiffness of the 170-μm-thick Kapton carrier by 60%. This result indicated that even the TFEA is ultra-flexible and that its bending stiffness should not be neglected in the design or selection of its carrier.

  20. Music Therapy for Preschool Cochlear Implant Recipients

    Science.gov (United States)

    Gfeller, Kate; Driscoll, Virginia; Kenworthy, Maura; Van Voorst, Tanya

    2010-01-01

    This paper provides research and clinical information relevant to music therapy for preschool children who use cochlear implants (CI). It consolidates information from various disciplinary sources regarding (a) cochlear implantation of young prelingually-deaf children (~age 2-5), (b) patterns of auditory and speech-language development, and (c) research regarding music perception of children with CIs. This information serves as a foundation for the final portion of the article, which describes typical music therapy goals and examples of interventions suitable for preschool children. PMID:23904691

  1. Chest radiology

    International Nuclear Information System (INIS)

    Reed, J.C.

    1990-01-01

    This book is a reference in plain chest film diagnosis provides a thorough background in the differential diagnosis of 22 of the most common radiologic patterns of chest disease. Each chapter is introduced with problem cases and a set of questions, followed by a tabular listing of the appropriate differential considerations. The book emphasizes plain films, CT and some MR scans are integrated to demonstrate how these modalities enhance the work of a case

  2. Follow-up of cochlear implant use in patients who developed bacterial meningitis following cochlear implantation.

    Science.gov (United States)

    Mancini, Patrizia; D'Elia, Chiara; Bosco, Ersilia; De Seta, Elio; Panebianco, Valeria; Vergari, Valeria; Filipo, Roberto

    2008-08-01

    The present study is a long-term follow-up of speech perception outcomes and cochlear implant use in three cases of meningitis that occurred after cochlear implantation. Case series study. Study was performed on three children implanted with different models of Clarion devices, two of them with positioner. Recognition and comprehension were assessed via the Italian adaptation of GASP (TAP) test, and phonetically balanced bi-syllabic words in open-set. High resolution computed tomography scan acquisition was performed to obtain axial coronal and oblique multiplanar reconstructions of the cochlea. Two patients were affected by enlarged cochlear acqueduct and Mondini malformation the first carrying positioner. One patient had a normal cochlea, and the positioner could have been the main cause of bacterial spread. As a consequence of meningitis the child with normal cochlea and the other with enlarged vestibular acqueduct developed cochlear ossification, increased M-level and worsening of hearing outcomes. The child with Mondini malformation developed facial nerve stimulation. Contralateral implantation was performed in the first two patients. Bacterial meningitis occurring after cochlear implantation may induce cochlear ossification, facial nerve stimulation, and permanent or temporary loss of implant use. Planned follow-up with high resolution computed tomography and evaluation of M-levels could be useful prognostic tools in the management of these patients.

  3. Modeling and segmentation of intra-cochlear anatomy in conventional CT

    Science.gov (United States)

    Noble, Jack H.; Rutherford, Robert B.; Labadie, Robert F.; Majdani, Omid; Dawant, Benoit M.

    2010-03-01

    Cochlear implant surgery is a procedure performed to treat profound hearing loss. Since the cochlea is not visible in surgery, the physician uses anatomical landmarks to estimate the pose of the cochlea. Research has indicated that implanting the electrode in a particular cavity of the cochlea, the scala tympani, results in better hearing restoration. The success of the scala tympani implantation is largely dependent on the point of entry and angle of electrode insertion. Errors can occur due to the imprecise nature of landmark-based, manual navigation as well as inter-patient variations between scala tympani and the anatomical landmarks. In this work, we use point distribution models of the intra-cochlear anatomy to study the inter-patient variations between the cochlea and the typical anatomic landmarks, and we implement an active shape model technique to automatically localize intra-cochlear anatomy in conventional CT images, where intra-cochlear structures are not visible. This fully automatic segmentation could aid the surgeon to choose the point of entry and angle of approach to maximize the likelihood of scala tympani insertion, resulting in more substantial hearing restoration.

  4. [Meta-analysis of the efficacy of cochlear implantation in deaf patients with inner ear malformation].

    Science.gov (United States)

    Xu, Qingqing; Zhai, Suoqiang; Han, Dongyi; Yang, Shiming; Shen, Weidong

    2014-04-01

    Assess and compare the clinical efficacy and safety of cochlear implantation in deaf patients with inner ear malformation and in the ones with normal inner ear structure, so that to clarify whether it is effective to restore hearing for the deaf patients with inner ear malformation. The literature with relevant key words were retrieved in the databases including PubMed, YZ365. com, WANFANG data, CMJD, CHKD and CNKI with language limited to Chinese and English. Extracted data included author, year of publication, diagnosis, treatment, et al. The clinical efficacy of cochlear implantation was assessed by the complications, electrode impedance, behavior T-level, hearing abilities and speech discrimination. Meta-analysis was performed using random or fixed effects model according to the heterogeneity of data. There were 11 randomized control studies involving 655 patients included in this study. There was no statistically significant difference among the deaf patients in mixed inner ear-malformation group, Mondini group and large vestibular aqueduct syndrome group in the aspects of postoperative complications, electrode impedance, behavior T-level, hearing abilities and speech discrimination. Cochlear implantation could be the way of treatment and rehabilitation for deaf patients with inner ear malformation. Further controlled studies with longer follow-up periods and more multiracial cases included may help to evaluate the efficacy of cochlear implantation for deaf patients with inner ear malformation more reliably.

  5. The hearing benefit of cochlear implantation for individuals with unilateral hearing loss, but no tinnitus.

    Science.gov (United States)

    Skarzynski, Henryk; Lorens, Artur; Kruszynska, Marika; Obrycka, Anita; Pastuszak, Dorota; Skarzynski, Piotr Henryk

    2017-07-01

    Cochlear implants improve the hearing abilities of individuals with unilateral hearing loss and no tinnitus. The benefit is no different from that seen in patients with unilateral hearing loss and incapacitating tinnitus. To evaluate hearing outcomes after cochlear implantation in individuals with unilateral hearing loss and no tinnitus and compare them to those obtained in a similar group who had incapacitating tinnitus. Six cases who did not experience tinnitus before operation and 15 subjects with pre-operative tinnitus were evaluated with a structured interview, a monosyllabic word test under difficult listening situations, a sound localization test, and an APHAB (abbreviated profile of hearing aid benefit) questionnaire. All subjects used their cochlear implant more than 8 hours a day, 7 days a week. In 'no tinnitus' patients, mean benefit of cochlear implantation was 19% for quiet speech, 15% for speech in noise (with the same signal-to-noise ratio in the implanted and non-implanted ear), and 16% for a more favourable signal-to-noise ratio at the implanted ear. Sound localization error improved by an average of 19°. The global score of APHAB improved by 16%. The benefits across all evaluations did not differ significantly between the 'no tinnitus' and 'tinnitus' groups.

  6. Cochlear Implantation in Siblings With Refsum's Disease.

    Science.gov (United States)

    Stähr, Kerstin; Kuechler, Alma; Gencik, Martin; Arnolds, Judith; Dendy, Meaghan; Lang, Stephan; Arweiler-Harbeck, Diana

    2017-08-01

    Whether the origin of severe hearing loss in Refsum's syndrome is caused by cochlear impairment or retrocochlear degeneration remains unclear. This case report aims to investigate hearing performance before and after cochlear implantation to shed light on this question. Also, identification of new mutations causing Refsum's syndrome would be helpful in generating additional means of diagnosis. A family of 4 individuals was subjected to genetic testing. Two siblings (56 and 61 years old) suffered from severe hearing and vision loss and received bilateral cochlear implants. Genetic analysis, audiological outcome, and clinical examinations were performed. One new mutation in the PHYH gene (c.768del63bp) causing Refsum's disease was found. Preoperative distortion product otoacoustic emissions (DPAOEs) were absent. Postoperative speech perception in Freiburger speech test was 100% for bisyllabic words and 85% (patient No. 1) and 65% (patient No. 2), respectively, for monosyllabic words. Five years after implantation, speech perception remained stable for bisyllabic words but showed decreasing capabilities for monosyllabic words. A new mutation causing Refsum's disease is presented. Cochlear implantation in case of severe hearing loss leads to an improvement in speech perception and should be recommended for patients with Refsum's disease, especially when the hearing loss is combined with a severe loss of vision. Decrease of speech perception in the long-term follow-up could indicate an additional retrocochlear degeneration.

  7. Libyan cochlear implant programme: achievements, difficulties, and ...

    African Journals Online (AJOL)

    Data relating to the patients who received cochlear implantation at Tripoli Medical Centre between October 2007 and February 2010 were analysed. Implant operations were performed on 37 patients. All patients received Med-El SONATATI100 devices. Thirty-four (91.9%) of these patients were children, whilst three (8.1%) ...

  8. Environmental Sound Training in Cochlear Implant Users

    Science.gov (United States)

    Shafiro, Valeriy; Sheft, Stanley; Kuvadia, Sejal; Gygi, Brian

    2015-01-01

    Purpose: The study investigated the effect of a short computer-based environmental sound training regimen on the perception of environmental sounds and speech in experienced cochlear implant (CI) patients. Method: Fourteen CI patients with the average of 5 years of CI experience participated. The protocol consisted of 2 pretests, 1 week apart,…

  9. Multichannel cochlear implantation in the scala vestibuli.

    Science.gov (United States)

    Lin, Karen; Marrinan, Michelle S; Waltzman, Susan B; Roland, J Thomas

    2006-08-01

    Sensorineural hearing loss resulting from otosclerosis, meningitis, chronic otitis media, autoimmune ear disease, and trauma can be associated with partial or total obstruction of the cochlear scalae. Multichannel cochlear implantation may be difficult in a cochlea with an obstructed scala tympani. The purpose of this study is to determine the safety and efficacy of scala tympani electrode insertion. Retrospective chart review. Academic medical center. Eight children and adults with profound sensorineural hearing loss who underwent cochlear implantation with known scala vestibuli electrode array insertion were subjects for this study. Eight study subjects underwent implantation: five with the Nucleus 24RCS (Contour) device and three with the Nucleus 24M device. Imaging findings, operative findings, and age-appropriate speech perception testing. All patients had full electrode insertion. Various obstructive patterns on computed tomography and magnetic resonance imaging were found, and there was a range of speech perception results. All but one patient improved based on age-appropriate monosyllabic word and sentence tests. Scala vestibuli multielectrode insertion is a viable alternative when scala tympani insertion is not possible because of abnormal anatomy or anatomical changes secondary to disease or previous implantation. We will also present an algorithm of options for decision making for implantation when encountering cochlear obstruction and difficult electrode insertion.

  10. Gender Categorization in Cochlear Implant Users

    Science.gov (United States)

    Massida, Zoe; Marx, Mathieu; Belin, Pascal; James, Christopher; Fraysse, Bernard; Barone, Pascal; Deguine, Olivier

    2013-01-01

    Purpose: In this study, the authors examined the ability of subjects with cochlear implants (CIs) to discriminate voice gender and how this ability evolved as a function of CI experience. Method: The authors presented a continuum of voice samples created by voice morphing, with 9 intermediate acoustic parameter steps between a typical male and a…

  11. Simplifying cochlear implant speech processor fitting

    NARCIS (Netherlands)

    Willeboer, C.

    2008-01-01

    Conventional fittings of the speech processor of a cochlear implant (CI) rely to a large extent on the implant recipient's subjective responses. For each of the 22 intracochlear electrodes the recipient has to indicate the threshold level (T-level) and comfortable loudness level (C-level) while

  12. The preoperative imaging evaluation for cochlear implantation

    International Nuclear Information System (INIS)

    Liu Zhonglin; Wang Zhenchang; Fu Lin; Li Yong; Xian Junfang; Yang Bentao; Lan Baosen; Li Yongxin; Zheng Jun; Song Yan; Liu Bo; Chen Xueqing; He Haili

    2006-01-01

    Objective: To analyze CT and MRI findings of temporal bone and to evaluate preoperative diagnostic value for cochlear implantation. Methods: One hundred and sixty candidates for cochlear implantation were examined with axial CT scan, 64 of them also with coronal CT scan, and 119 patients with MRI. Results: All of 320 ears were well-aerated, and 206 ears had mastoid cavities extended posteriorly to the sigmoid sinus. The length from posterior-lateral tympanic wall to the outer cortex was (2.34±0.42) mm (left side) and (2.25±0.40) mm (right side) (U=1.887, P 1 and T 2 signal on MRI. The congenital malformations of inner ear occurred in 67 ears, including complete dysplasia in 1 ear, cochlear hypodysplasia in 6 ears, Mondini deformation in 5 ears, enlarged vestibular aqueduct in 40 ears, dysplastic semicircular canal and the vestibulae in 10 ears, and narrowing of internal auditory canal in 5 ears. Conclusion: Preoperative imaging examinations can provide critical information to ensure successful cochlear' implantation. (authors)

  13. Listening Effort With Cochlear Implant Simulations

    NARCIS (Netherlands)

    Pals, Carina; Sarampalis, Anastasios; Başkent, Deniz

    2013-01-01

    Purpose: Fitting a cochlear implant (CI) for optimal speech perception does not necessarily optimize listening effort. This study aimed to show that listening effort may change between CI processing conditions for which speech intelligibility remains constant. Method: Nineteen normal-hearing

  14. Cochlear implant-related three-dimensional characteristics determined by micro-computed tomography reconstruction.

    Science.gov (United States)

    Ni, Yusu; Dai, Peidong; Dai, Chunfu; Li, Huawei

    2017-01-01

    To explore the structural characteristics of the cochlea in three-dimensional (3D) detail using 3D micro-computed tomography (mCT) image reconstruction of the osseous labyrinth, with the aim of improving the structural design of electrodes, the selection of stimulation sites, and the effectiveness of cochlear implantation. Three temporal bones were selected from among adult donors' temporal bone specimens. A micro-CT apparatus (GE eXplore) was used to scan three specimens with a voxel resolution of 45 μm. We obtained about 460 slices/specimen, which produced abundant data. The osseous labyrinth images of three specimens were reconstructed from mCT. The cochlea and its spiral characteristics were measured precisely using Able Software 3D-DOCTOR. The 3D images of the osseous labyrinth, including the cochlea, vestibule, and semicircular canals, were reconstructed. The 3D models of the cochlea showed the spatial relationships and surface structural characteristics. Quantitative data concerning the cochlea and its spiral structural characteristics were analyzed with regard to cochlear implantation. The 3D reconstruction of mCT images clearly displayed the detailed spiral structural characteristics of the osseous labyrinth. Quantitative data regarding the cochlea and its spiral structural characteristics could help to improve electrode structural design, signal processing, and the effectiveness of cochlear implantation. Clin. Anat. 30:39-43, 2017. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  15. Diagnostic radiology 1987

    International Nuclear Information System (INIS)

    Margulis, A.R.; Gooding, C.A.

    1987-01-01

    This is the latest version of the continuing education course on diagnostic radiology given yearly by the Department of Radiology at the University of California, San Francisco. The lectures are grouped into sections on gastrointestinal radiology, mammography, uroradiology, magnetic resonance, hepatobiliary radiology, pediatric radiology, ultrasound, interventional radiology, chest radiology, nuclear medicine, cardiovascular radiology, and skeletal radiology. Each section contains four to eight topics. Each of these consists of text that represents highlights in narrative form, selected illustrations, and a short bibliography. The presentation gives a general idea of what points were made in the lecture

  16. Cardiothoracic radiology

    International Nuclear Information System (INIS)

    Scarsbrook, A.F.; Graham, R.N.J.; Perriss, R.W.

    2005-01-01

    A wealth of cardiothoracic websites exist on the internet. What follows is a list of the higher quality resources currently available which should save you time searching them out for yourself. Many of the sites listed cater for undergraduates and trainee or non-specialist radiologists, nevertheless these may also be of interest to specialists in thoracic radiology, particularly for use in teaching. Hyperlinks are available in the electronic version of this article and were all active at the time of going to press (April 2005)

  17. Pediatric radiology

    International Nuclear Information System (INIS)

    Silverman, F.N.

    1982-01-01

    A literature review with 186 references of diagnostic pediatric radiology, a speciality restricted to an age group rather than to an organ system or technique of examination, is presented. In the present chapter topics follow the basic organ system divisions with discussions of special techniques within these divisions. The diagnosis of congenital malformations, infectious diseases and neoplasms are a few of the topics discussed for the head and neck region, the vertebrae, the cardiovascular system, the respiratory system, the gastrointestinal tract, the urinary tract, and the skeleton

  18. Anomalous facial nerve canal with cochlear malformations.

    Science.gov (United States)

    Romo, L V; Curtin, H D

    2001-05-01

    Anteromedial "migration" of the first segment of the facial nerve canal has been previously identified in a patient with a non-Mondini-type cochlear malformation. In this study, several patients with the same facial nerve canal anomaly were reviewed to assess for the association and type of cochlear malformation. CT scans of the temporal bone of 15 patients with anteromedial migration of the first segment of the facial nerve canal were collected from routine departmental examinations. In seven patients, the anomalous course was bilateral, for a total of 22 cases. The migration was graded relative to normal as either mild/moderate or pronounced. The cochlea in each of these cases was examined for the presence and size of the basilar, second, and apical turns. The turns were either absent, small, normal, or enlarged. The CT scans of five patients with eight Mondini malformations were examined for comparison. The degree of the facial nerve migration was pronounced in nine cases and mild/moderate in 13. All 22 of these cases had associated cochlear abnormalities of the non-Mondini variety. These included common cavity anomalies with lack of definition between the cochlea and vestibule (five cases), cochleae with enlarged basilar turns and absent second or third turns (five cases), and cochleae with small or normal basilar turns with small or absent second or third turns (12 cases). None of the patients with Mondini-type cochlear malformations had anteromedial migration of the facial nerve canal. Anteromedial migration of the facial nerve canal occurs in association with some cochlear malformations. It did not occur in association with the Mondini malformations. A cochlea with a Mondini malformation, being similar in size to a normal cochlea, may physically prohibit such a deviation in course.

  19. [Morphologic feature and cochlear implant surgical approach for cochlear modiolus deficiency].

    Science.gov (United States)

    Zhang, Daoxing

    2014-09-01

    To review the classification of cochlear modiolus deficiency and decision on surgical approach for above case,in order to provide mastery for cochlear implant (CI) indication. Basing on temporal bone HRCT pre-operation, CI subjects with modiolus deficiency were defined as following groups: (1) deficiency caused by cochlear dysplasia (Mondini malformation); (2) deficiency caused by dysplasia of cochlear and vestibule (Common cavity malformation); (3) deficiency caused by absence of internal acoustic meatus fundus (IP-III malformation). Three types of surgical approach were utilized: type I, electrode array was introduced through facial recess, enlarged the round window, type II, opened the surface of chchlea, electrode array was introduced through facial recess, fenestration on posterior promontory and then inserted around lateral wall of inner-cochlear cavity. type III, electrode array was introduce through fenestration of lateral semicircular canal and then placed close to the bony wall of common cavity. One hundred and sixty-six cochlear modiolus deficiency cases were identified into 3 groups as following: 135 Mondini malformation cases into group a, 18 common cavity malformation cases into group b, and 13 IP-III malformation cases into group c. Surgical approach: type I were used in 136 cases (123 Mondini cases and 13 IP-III cases), while approach type II in 12 cases (12 Mondini cases), and approach type III in 18 cases (18 common cavity cases). Income post-operation of CI: For group a (Mondini malformation), post-activation mean hearing threshold in sound field was 65 dB, speech recognition score is 95% (single finals test) and 25% (signal initials test), while it was 80 dB, 60% and 0 for group b (Conmon cavity malformation), and it was 55 dB, 100% and 45% for group c (IP-III malformation). The income of speech recognition score for cochlear modiolus deficiency was relatively poor, group b was worst and group c was best, while group a moderate.

  20. Radiological effects

    International Nuclear Information System (INIS)

    Anon.

    1978-01-01

    Environmental monitoring in the vicinity of the Calvert Cliffs Nuclear Power Plant has been shown the radiation dose to the public from plant operation to be quite small. Calculations from the reported release rates yield 0.2 mrem whole body dose and 0.6 mrem skin dose for the calendar quarter of maximum release. Radioactivity discharges to the Chesapeake Bay have resulted in detectable concentrations of /sup 110m/Ag, 58 Co, and 60 Co in sediments and shellfish. The area yielding samples with detectable concentrations of plant effluents extends for roughly six miles up and down the western shore, with maximum values found at the plant discharge area. The radiation dose to an individual eating 29 doz oysters and 15 doz crabs (5 kg of each) taken from the plant discharge area would be about 4/1000 mrem whole body dose and 0.2 mrem gastrointestinal tract dose (about 0.007% and 0.5% of the applicable guidelines, respectively.) Comparison of these power plant-induced doses with the fluctuations in natural radiation dose already experienced by the public indicates that the power plant effects are insignificant. The natural variations are tens of times greater than the maximum doses resulting from Calvert Cliffs Power Plant. Although operations to date provide an insufficient basis to predict radiological impact of the Calvert Cliffs Plant over its operational lifetime, available data indicate that the plant should continue to operate with insignificant radiological impact, well within all applicable guidelines

  1. Pediatric radiology

    International Nuclear Information System (INIS)

    Kirkpatrick, J.A. Jr.

    1985-01-01

    Computed tomography has made possible the excellent and basic work having to do with the characteristics of the trachea, its caliber, shape, and length in children. Another group of articles has to do with interventional pediatric radiology. This year there were a number of articles of which only a sample is included, dealing with therapeutic procedures involving drainage of abscesses, angioplasty, nephrostomy, therapeutic embolization, and the removal of esophageal foreign bodies. Obviously, there is no reason to think that techniques developed for the adult may not be applicable to the infant or child; also, there is no reason to believe that processes peculiar to the child should not be amenable to intervention, for instance, use of embolization of hepatic hemangioma and transluminal balloon valvuloplasty for pulmonary valvular stenosis. Among the reports and reviews, the author would add that sonography remains a basic imaging technique in pediatric radiology and each year its application broadens. For example, there is an excellent article having to do with sonography of the neonatal and infant hip and evaluation of the inferior vena cava and the gallbladder. Nuclear medicine continues to play a significant role in diagnosis, which is featured in two articles concerned with problems of the hip

  2. Radiological malpractice

    International Nuclear Information System (INIS)

    Bauer, G.

    1987-01-01

    As medico-legal statistics show, compared with other branches of medicine, cases of liability of the radiologist or his assistants are relatively rare. The duty to exercise due care as set out in Paragraph 6 of the Austrian penal code or Paragraph 276 of the German civil code, respectively, provide a basic rule of law also for radiology. Due to the risk inherent in the investigation method, incidents in angiography cannot be totally excluded. Therefore, it is of utmost importance that all steps be taken with regard to staff, equipment and drugs to be able to deal with any complications and incidents that may arise. The courts of law require the employer to produce strongest exonerating evidence to prove that the duty to exercise due care in the selection and supervision of the assistants has been duly fulfilled. For the practical execution of radiological investigations of the digestive tract, also the RTA is responsible; her liability when performing an irrigoscopy is particularly great, as perforation of the intestine is often lethal. The introduction of the rectal tube into the vagina by mistake, with resultant injury or death of the patient, will regularly lead to conviction under penal law. (orig.) [de

  3. Procedures in diagnostic radiology

    International Nuclear Information System (INIS)

    Doyle, T.; Hare, W.S.C.; Thomson, K.; Tess, B.

    1989-01-01

    This book outlines the various procedures necessary for the successful practice of diagnostic radiology. Topics covered are: general principles, imaging of the urinary and gastrointestinal tracts, vascular radiology, arthrography, and miscellaneous diagnostic radiologic procedures

  4. What Does Music Sound Like for a Cochlear Implant User?

    Science.gov (United States)

    Jiam, Nicole T; Caldwell, Meredith T; Limb, Charles J

    2017-09-01

    Cochlear implant research and product development over the past 40 years have been heavily focused on speech comprehension with little emphasis on music listening and enjoyment. The relatively little understanding of how music sounds in a cochlear implant user stands in stark contrast to the overall degree of importance the public places on music and quality of life. The purpose of this article is to describe what music sounds like to cochlear implant users, using a combination of existing research studies and listener descriptions. We examined the published literature on music perception in cochlear implant users, particularly postlingual cochlear implant users, with an emphasis on the primary elements of music and recorded music. Additionally, we administered an informal survey to cochlear implant users to gather first-hand descriptions of music listening experience and satisfaction from the cochlear implant population. Limitations in cochlear implant technology lead to a music listening experience that is significantly distorted compared with that of normal hearing listeners. On the basis of many studies and sources, we describe how music is frequently perceived as out-of-tune, dissonant, indistinct, emotionless, and weak in bass frequencies, especially for postlingual cochlear implant users-which may in part explain why music enjoyment and participation levels are lower after implantation. Additionally, cochlear implant users report difficulty in specific musical contexts based on factors including but not limited to genre, presence of lyrics, timbres (woodwinds, brass, instrument families), and complexity of the perceived music. Future research and cochlear implant development should target these areas as parameters for improvement in cochlear implant-mediated music perception.

  5. [The development of musicality in children after cochlear implantation].

    Science.gov (United States)

    Zheng, Yan; Liu, Bo; Dong, Ruijuan; Xu, Tianqiu; Chen, Jing; Chen, Xuejing; Zhong, Yan; Meng, Chao; Wang, Hong; Chen, Xueqing

    2014-08-01

    The purpose of this study is to analyze the development of musicality in children after cochlear implantation, and provide a clinical database for the evaluation of their musicality. Twenty-six children with cochlear implants (CI group) participated in this research. They received cochlear implants at the age of 11 to 68 months with a mean of 35.6 months. Seventy-six infants as a control group aged from 1 to 24 months with a mean of 6.1 months participated in this study, whose hearing were considered normal by passing the case history collection, high-risk registers for hearing loss and hearing screening using DPOAE. The music and young children with CIs: Musicality Rating Scale was used to evaluate their musicality. The evaluation was performed before cochlear implantation and 1, 3, 6, 9, 12, 24 months after cochlear implantation for children with cochlear implants. The evaluation was also performed at 1, 3, 6, 9, 12, 24 months for children with normal hearing. The mean scores of musicality showed significant improvements with time of CI use for CI group (Pmusicality also showed significant improvements with time for control group (P0.05). Significant difference was noted between the two groups at 24 months (Pmusicality of children with cochlear implants improved significantly with time after cochlear implantation. The most rapid growth was found in the first year after cochlear implantation.

  6. Management of Radiological emergencies

    International Nuclear Information System (INIS)

    Lentijo, J. C.; Gil, E.; San Nicolas, J.; Lazuen, J. A.

    2004-01-01

    Spain has a system of planning and response to emergency situations that is structured and coordinated by the General Directorship of civil Defense of the Ministry of the Interior and in which all levels of the Public Administration. state, autonomous and municipal-and owners of potentially hazardous activities participate. Activities involving a nuclear or radiological risk have specific emergency plans whose general principles are based on the general emergency system and whose technical bases are consistent with international practices and recommendations. The Consejo de Seguridad Nuclear actively participates in the design, implementation and activation of these plans, and for this purpose has an organization superimposed on its ordinary working organization that is activated in the event of an accident, as well as an Emergency Room specifically designed to deal with nuclear and radiological emergencies. (Author)

  7. Radiologic diagnostics of dementia

    International Nuclear Information System (INIS)

    Essig, M.; Schoenberg, S.O.

    2003-01-01

    Dementia is one of the most common diseases in the elderly population and is getting more and more important with the ageing of the population. A radiologic structural examination with CT or MRI is meanwhile a standard procedure in the diagnostic work up of patients with dementia syndrome. Radiology enables an early diagnosis and a differential diagnosis between different causes of dementia. Because structural changes occur only late in the disease process, a more detailed structural analysis using volumetric techniques or the use of functional imaging techniques is mandatory. These days, structural imaging uses MRI which enables to detect early atrophic changes at the medial temporal lobe with focus on the amygdala hippocampal complex. These changes are also present in the normal ageing process. In patients with Alzheimer's disease, however, they are more rapid and more pronounced. The use of functional imaging methods such as perfusion MRI, diffusion MRI or fMRI allow new insights into the pathophysiologic changes of dementia. The article gives an overview of the current status of structural imaging and an outlook into the potential of functional imaging methods. Detailed results of structural and functional imaging are presented in other articles of this issue. (orig.) [de

  8. Digital radiology

    International Nuclear Information System (INIS)

    Dallas, W.J.

    1990-01-01

    Radiology is vital to the life-saving efforts of surgeons and other physicians, but precious time can be lost generating the images and transferring them to and from the operating room. Furthermore, hospitals are straining under the task of storing and managing the deluge of diagnostic films produced every year. A 300-bed hospital generates about 1 gigabyte (8 x 10 9 bits) of picture information every day and is legally bound to hold it for three to seven years--30 years in the case of silicosis or black lung disease, illnesses that may have relevance to future lawsuits. Consequently, hospital warehouses are filling with x-ray film and written reports that are important for analysis of patient histories, for comparison between patients, and for analyzing the progress of disease. Yet only a fraction of the information's potential is being used because access is so complicated. What is more, films are easily lost, erasing valuable medical histories

  9. Partial corrosion casting to assess cochlear vasculature in mouse models of presbycusis and CMV infection.

    Science.gov (United States)

    Carraro, Mattia; Park, Albert H; Harrison, Robert V

    2016-02-01

    Some forms of sensorineural hearing loss involve damage or degenerative changes to the stria vascularis and/or other vascular structures in the cochlea. In animal models, many methods for anatomical assessment of cochlear vasculature exist, each with advantages and limitations. One methodology, corrosion casting, has proved useful in some species, however in the mouse model this technique is difficult to achieve because digestion of non vascular tissue results in collapse of the delicate cast specimen. We have developed a partial corrosion cast method that allows visualization of vasculature along much of the cochlear length but maintains some structural integrity of the specimen. We provide a detailed step-by-step description of this novel technique. We give some illustrative examples of the use of the method in mouse models of presbycusis and cytomegalovirus (CMV) infection. Copyright © 2015 Elsevier B.V. All rights reserved.

  10. Meningitis after cochlear implantation in Mondini malformation.

    Science.gov (United States)

    Page, E L; Eby, T L

    1997-01-01

    Although the potential for CSF leakage and subsequent meningitis after cochlear implantation in the malformed cochlea has been recognized, this complication has not been previously reported. We report a case of CSF otorhinorrhea and meningitis after minor head trauma developing 2 years after cochlear implantation in a child with Mondini malformation. Leakage of CSF was identified from the cochleostomy around the electrode of the implant, and this leak was sealed with a temporalis fascia and muscle plug. Although this complication appears to be rare, care must be taken to seal the cochleostomy in children with inner ear malformations at the initial surgery, and any episode of meningitis after surgery must be thoroughly investigated to rule out CSF leakage from the labyrinth.

  11. Prevention of Noise Damage to Cochlear Synapses

    Science.gov (United States)

    2017-10-01

    Assessment of synapse regeneration : Twelve week old CBA/CaJ mice are exposed to a moderate noise that destroys synapses on inner hair cells (IHCs) but spares...result of excitotoxic trauma to cochlear synapses due to glutamate released from the hair cells . Excitotoxic trauma damages the postsynaptic cell by...components ............................................. 12 d) Quantitative analysis of effects of neurotrophic factors on synapse regeneration in vitro

  12. Radiologic protection in dental radiology

    International Nuclear Information System (INIS)

    Pacheco Jimenez, R.E.; Bermudez Jimenez, L.A.

    2000-01-01

    With this work and employing the radioprotection criterion, the authors pretend to minimize the risks associated to this practice; without losing the quality of the radiologic image. Odontology should perform the following criterions: 1. Justification: all operation of practice that implies exposition to radiations, should be reweighed, through an analysis of risks versus benefits, with the purpose to assure, that the total detriment will be small, compared to resultant benefit of this activity. 2. Optimization: all of the exposures should be maintained as low as reasonable possible, considering the social and economic factors. 3. Dose limit: any dose limit system should be considered as a top condition, nota as an admissible level. (S. Grainger)

  13. Do Adults with Cochlear Implants Rely on Different Acoustic Cues for Phoneme Perception than Adults with Normal Hearing?

    Science.gov (United States)

    Moberly, Aaron C.; Lowenstein, Joanna H.; Tarr, Eric; Caldwell-Tarr, Amanda; Welling, D. Bradley; Shahin, Antoine J.; Nittrouer, Susan

    2014-01-01

    Purpose: Several acoustic cues specify any single phonemic contrast. Nonetheless, adult, native speakers of a language share weighting strategies, showing preferential attention to some properties over others. Cochlear implant (CI) signal processing disrupts the salience of some cues: In general, amplitude structure remains readily available, but…

  14. Hearing Preservation in Cochlear Implant Surgery

    Directory of Open Access Journals (Sweden)

    Priscila Carvalho Miranda

    2014-01-01

    Full Text Available In the past, it was thought that hearing loss patients with residual low-frequency hearing would not be good candidates for cochlear implantation since insertion was expected to induce inner ear trauma. Recent advances in electrode design and surgical techniques have made the preservation of residual low-frequency hearing achievable and desirable. The importance of preserving residual low-frequency hearing cannot be underestimated in light of the added benefit of hearing in noisy atmospheres and in music quality. The concept of electrical and acoustic stimulation involves electrically stimulating the nonfunctional, high-frequency region of the cochlea with a cochlear implant and applying a hearing aid in the low-frequency range. The principle of preserving low-frequency hearing by a “soft surgery” cochlear implantation could also be useful to the population of children who might profit from regenerative hair cell therapy in the future. Main aspects of low-frequency hearing preservation surgery are discussed in this review: its brief history, electrode design, principles and advantages of electric-acoustic stimulation, surgical technique, and further implications of this new treatment possibility for hearing impaired patients.

  15. Pitfalls in diagnostic radiology

    Energy Technology Data Exchange (ETDEWEB)

    Peh, Wilfred C.G. (ed.) [Khoo Teck Puat Hospital (Singapore). Dept. of Diagnostic Radiology

    2015-04-01

    Only textbook to focus primarily on the topic of pitfalls in diagnostic radiology. Highlights the pitfalls in a comprehensive and systematic manner. Written by experts in different imaging modalities and subspecialties from reputable centers across the world. The practice of diagnostic radiology has become increasingly complex, with the use of numerous imaging modalities and division into many subspecialty areas. It is becoming ever more difficult for subspecialist radiologists, general radiologists, and residents to keep up with the advances that are occurring year on year, and this is particularly true for less familiar topics. Failure to appreciate imaging pitfalls often leads to diagnostic error and misinterpretation, and potential medicolegal problems. Diagnostic errors may be due to various factors such as inadequate imaging technique, imaging artifacts, failure to recognize normal structures or variants, lack of correlation with clinical and other imaging findings, and poor training or inexperience. Many, if not most, of these factors are potentially recognizable, preventable, or correctable. This textbook, written by experts from reputable centers across the world, systematically and comprehensively highlights the pitfalls that may occur in diagnostic radiology. Both pitfalls specific to different modalities and techniques and those specific to particular organ systems are described with the help of numerous high-quality illustrations. Recognition of these pitfalls is crucial in helping the practicing radiologist to achieve a more accurate diagnosis.

  16. Pitfalls in diagnostic radiology

    International Nuclear Information System (INIS)

    Peh, Wilfred C.G.

    2015-01-01

    Only textbook to focus primarily on the topic of pitfalls in diagnostic radiology. Highlights the pitfalls in a comprehensive and systematic manner. Written by experts in different imaging modalities and subspecialties from reputable centers across the world. The practice of diagnostic radiology has become increasingly complex, with the use of numerous imaging modalities and division into many subspecialty areas. It is becoming ever more difficult for subspecialist radiologists, general radiologists, and residents to keep up with the advances that are occurring year on year, and this is particularly true for less familiar topics. Failure to appreciate imaging pitfalls often leads to diagnostic error and misinterpretation, and potential medicolegal problems. Diagnostic errors may be due to various factors such as inadequate imaging technique, imaging artifacts, failure to recognize normal structures or variants, lack of correlation with clinical and other imaging findings, and poor training or inexperience. Many, if not most, of these factors are potentially recognizable, preventable, or correctable. This textbook, written by experts from reputable centers across the world, systematically and comprehensively highlights the pitfalls that may occur in diagnostic radiology. Both pitfalls specific to different modalities and techniques and those specific to particular organ systems are described with the help of numerous high-quality illustrations. Recognition of these pitfalls is crucial in helping the practicing radiologist to achieve a more accurate diagnosis.

  17. Current radiology. Volume 5

    International Nuclear Information System (INIS)

    Wilson, G.H.; Hanafee, W.N.

    1984-01-01

    This book contains 10 selections. They are: Nuclear Magnetic Resonance Imaging, Interventional Vascular Radiology, Genitourinary Radiology, Skeletal Radiology, Digital Subtraction Angiography, Neuroradiology, Computed Tomographic Evaluation of Degenerative Diseases of the Lumbar Spine, The Lung, Otolaringology and Opthalmology, and Pediatric Radiology: Cranial, Facial, Cervical, Vertebral, and Appendicular

  18. Preservation of cell structures in a medieval infant brain: a paleohistological, paleogenetic, radiological and physico-chemical study.

    Science.gov (United States)

    Papageorgopoulou, Christina; Rentsch, Katharina; Raghavan, Maanasa; Hofmann, Maria Ines; Colacicco, Giovanni; Gallien, Véronique; Bianucci, Raffaella; Rühli, Frank

    2010-04-15

    Cerebral tissues from archaeological human remains are extremely rare findings. Hereby, we report a multidisciplinary study of a unique case of a left cerebral hemisphere from a 13th century AD child, found in north-western France. The cerebral tissue-reduced by ca. 80% of its original weight-had been fixed in formalin since its discovery. However, it fully retained its gross anatomical characteristics such as sulci, and gyri; the frontal, temporal and occipital lobe as well as grey and white matter could be readily recognised. Neuronal remains near the hippocampus area and Nissl bodies from the motor cortex area were observed (Nissl, Klüver-Barrera staining). Also, computed tomography (CT) and magnetic resonance imaging (T1, proton density, ultra short echo time sequences) were feasible. They produced high quality morpho-diagnostic images. Both histological and radiological examinations could not confirm the pathologist's previously suggested diagnosis of cerebral haemorrhage as the cause of death. Reproducible cloned mtDNA sequences were recovered from the skeleton but not from the brain itself. This was most likely due to the combined effect of formaldehyde driven DNA-DNA and/or DNA-protein cross-linking, plus hydrolytic fragmentation of the DNA. The chemical profile of the brain tissue, from gas-chromatography/mass-spectroscopy analysis, suggested adipocerous formation as the main aetiology of the mummification process. The hereby presented child brain is a unique paleo-case of well-preserved neuronal cellular tissue, which is a conditio sine qua non for any subsequent study addressing wider perspectives in neuroscience research, such as the evolution of brain morphology and pathology. Copyright 2010 Elsevier Inc. All rights reserved.

  19. Radiological Control Manual

    Energy Technology Data Exchange (ETDEWEB)

    1993-04-01

    This manual has been prepared by Lawrence Berkeley Laboratory to provide guidance for site-specific additions, supplements, and clarifications to the DOE Radiological Control Manual. The guidance provided in this manual is based on the requirements given in Title 10 Code of Federal Regulations Part 835, Radiation Protection for Occupational Workers, DOE Order 5480.11, Radiation Protection for Occupational Workers, and the DOE Radiological Control Manual. The topics covered are (1) excellence in radiological control, (2) radiological standards, (3) conduct of radiological work, (4) radioactive materials, (5) radiological health support operations, (6) training and qualification, and (7) radiological records.

  20. Radiological Control Manual

    International Nuclear Information System (INIS)

    1993-04-01

    This manual has been prepared by Lawrence Berkeley Laboratory to provide guidance for site-specific additions, supplements, and clarifications to the DOE Radiological Control Manual. The guidance provided in this manual is based on the requirements given in Title 10 Code of Federal Regulations Part 835, Radiation Protection for Occupational Workers, DOE Order 5480.11, Radiation Protection for Occupational Workers, and the DOE Radiological Control Manual. The topics covered are (1) excellence in radiological control, (2) radiological standards, (3) conduct of radiological work, (4) radioactive materials, (5) radiological health support operations, (6) training and qualification, and (7) radiological records

  1. The long-term concerns post cochlear implantation as experienced ...

    African Journals Online (AJOL)

    Background. Cochlear implantation aims to provide an effective means of spoken communication for prelingually deaf children. However, studies in this field are mostly clinically orientated, with little focus on the experiences and long-term concerns of families post cochlear implantation (CI). Objective. To describe the ...

  2. Emotion Understanding in Deaf Children with a Cochlear Implant

    Science.gov (United States)

    Wiefferink, Carin H.; Rieffe, Carolien; Ketelaar, Lizet; De Raeve, Leo; Frijns, Johan H. M.

    2013-01-01

    It is still largely unknown how receiving a cochlear implant affects the emotion understanding in deaf children. We examined indices for emotion understanding and their associations with communication skills in children aged 2.5-5 years, both hearing children (n = 52) and deaf children with a cochlear implant (n = 57). 2 aspects of emotion…

  3. Remote programming of cochlear implants: a telecommunications model.

    Science.gov (United States)

    McElveen, John T; Blackburn, Erin L; Green, J Douglas; McLear, Patrick W; Thimsen, Donald J; Wilson, Blake S

    2010-09-01

    Evaluate the effectiveness of remote programming for cochlear implants. Retrospective review of the cochlear implant performance for patients who had undergone mapping and programming of their cochlear implant via remote connection through the Internet. Postoperative Hearing in Noise Test and Consonant/Nucleus/Consonant word scores for 7 patients who had undergone remote mapping and programming of their cochlear implant were compared with the mean scores of 7 patients who had been programmed by the same audiologist over a 12-month period. Times required for remote and direct programming were also compared. The quality of the Internet connection was assessed using standardized measures. Remote programming was performed via a virtual private network with a separate software program used for video and audio linkage. All 7 patients were programmed successfully via remote connectivity. No untoward patient experiences were encountered. No statistically significant differences could be found in comparing postoperative Hearing in Noise Test and Consonant/Nucleus/Consonant word scores for patients who had undergone remote programming versus a similar group of patients who had their cochlear implant programmed directly. Remote programming did not require a significantly longer programming time for the audiologist with these 7 patients. Remote programming of a cochlear implant can be performed safely without any deterioration in the quality of the programming. This ability to remotely program cochlear implant patients gives the potential to extend cochlear implantation to underserved areas in the United States and elsewhere.

  4. A case report: the first successful cochlear implant in Uganda.

    African Journals Online (AJOL)

    A case report: the first successful cochlear implant in Uganda. Richard Byaruhanga1, J. ... The patient was a 23 year old male whose presenting com- plaint was inability to .... Custom Sound by Cochlear (the company that manu- factures the ...

  5. Verbal Working Memory in Children with Cochlear Implants

    Science.gov (United States)

    Nittrouer, Susan; Caldwell-Tarr, Amanda; Low, Keri E.; Lowenstein, Joanna H.

    2017-01-01

    Purpose: Verbal working memory in children with cochlear implants and children with normal hearing was examined. Participants: Ninety-three fourth graders (47 with normal hearing, 46 with cochlear implants) participated, all of whom were in a longitudinal study and had working memory assessed 2 years earlier. Method: A dual-component model of…

  6. Are parents of children with cochlear implants coping?: research ...

    African Journals Online (AJOL)

    Many variables must be considered during the evaluation and rehabilitation of children for cochlear implantation, one of which is parental influence (for the duration of this report the parents, caregivers and guardians of children with cochlear implants and / or hearing impairments will be referred to as 'parents'). The aim of ...

  7. Congenitally Deafblind Children and Cochlear Implants: Effects on Communication

    Science.gov (United States)

    Dammeyer, Jesper

    2009-01-01

    There has been much research conducted demonstrating the positive benefits of cochlear implantation (CI) in children who are deaf. Research on CI in children who are both deaf and blind, however, is lacking. The purpose of this article is to present a study of five congenitally deafblind children who received cochlear implants between 2.2 and 4.2…

  8. Cochlear implantation in X-linked deafness - How to manage the surgical challenges.

    Science.gov (United States)

    Saeed, Haroon; Powell, Harry R F; Saeed, Shakeel R

    2016-07-01

    In children with X-linked deafness, cochlear malformations challenge the implant surgeon to avoid electrode insertion into the internal auditory meatus and prevent a continuous cerebrospinal fluid (CSF) leak. We describe our experience of cochlear implantation (CI) in two children with profound hearing loss secondary to X-linked deafness, highlighting safer operative techniques to avoid potential complications. Descriptive cases of two children with X-linked deafness (patient 1 and patient 2) undergoing CI. Peri-operative imaging and work-up to surgery are discussed. Specific operative considerations, post-operative complications and subsequent audiological performance are highlighted. In each case, intra-operative fluoroscopic imaging ensured intra-cochlear insertion of electrodes. Expected CSF gusher was seen in each case which was initially controlled by packing around the cochleostomy and array with temporalis muscle and fascia. Patient 1 developed post-operative meningitis secondary to continuous CSF leak. We avoided further significant CSF leak by planning staged procedures for patient 2, with obliteration of the middle ear cleft and external ear canal (EAC) at the time of implantation. In both patients, bilateral implantation successfully provided hearing thresholds of less than 35 dB in both ears at routine follow up. When planning for CI in children with radiological features of X-linked deafness, intra-operative imaging should be utilized to ensure correct electrode positioning. Traditional methods of stopping a CSF gusher may not suffice. We therefore encourage additional surgical obliteration of the middle ear space and EAC to avoid persistent CSF leak and its associated complications.

  9. Rehabilitation of deaf persons with cochlear implants; Rehabilitation Hoergeschaedigter mit Cochlearimplantaten

    Energy Technology Data Exchange (ETDEWEB)

    Gstoettner, W.; Hamzavi, J. [Universitaetsklinik fuer Hals-Nasen-Ohrenheilkunde, Wien (Austria); Czerny, C. [Universitaetsklinik fuer Radiologie, Wien (Austria)

    1997-12-01

    In the last decade, the rehabilitation of postlingually deaf adults and prelingually deaf children with cochlear implants has been established as a treatment of deafness. The technological development of the implant devices and improvement of the surgical technique have led to a considerable increase of hearing performance during the last years. The postlingually deaf adults are able to use the telephone and may be integrated in their original job. Prelingually deaf children can even visit normal schools after cochlear implantation and hearing rehabilitation training. In order to preoperatively establish the state of the cochlear, radiological diagnosis of the temporal bone is necessary. High resolution computerized tomography imaging of the temporal bone with coronar and axial 1 mm slices and MRI with thin slice technique (three dimensional, T2 weighted turbo-spinecho sequence with 0.7 mm slices) have proved to be valuable according to our experience. Furthermore a postoperative synoptical X-ray, in a modified Chausse III projection, offers good information about the position of the implant and insertion of the stimulating electrode into the cochlea. (orig.) [Deutsch] In der letzten Dekade hat sich der operative Einsatz von Cochlearimplantaten fuer die Rehabilitation taubgeborener Kinder und ertaubter Erwachsenen als erfolgreiche Therapie etabliert. Durch technische Weiterentwicklung der Implantatsysteme und Verbesserung der Operationstechnik konnten in den letzten Jahren die Hoerleistungen der Patienten deutlich verbessert werden. Postlingual ertaubte Erwachsene koennen nun oftmals wieder ins Berufsleben eingegliedert werden und praelingual ertaubte Kinder koennen regulaere Schulen besuchen. Im Rahmen der Voruntersuchung fuer die Cochlearimplantation ist die radiologische Felsenbeindiagnostik von besonderer Bedeutung. Hochaufloesendes CT des Felsenbeins in koronaren und axialen Ebenen mit 1 mm Schichtdicke und MRT in Duennschichttechnik (dreidimensionale, T2

  10. Gain and frequency tuning within the mouse cochlear apex

    Energy Technology Data Exchange (ETDEWEB)

    Oghalai, John S.; Raphael, Patrick D. [Department of Otolaryngology, Stanford University School of Medicine, Stanford, California (United States); Gao, Simon [Department of Otolaryngology, Stanford University School of Medicine, Stanford, California (United States); Department of Bioengineering, Rice University, Houston, Texas (United States); Lee, Hee Yoon [Department of Otolaryngology, Stanford University School of Medicine, Stanford, California (United States); Department of Electrical Engineering, Stanford University, Stanford, California (United States); Groves, Andrew K. [Department of Neuroscience, Department of Molecular and Human Genetics, and Program in Developmental Biology, Baylor College of Medicine, Houston, Texas (United States); Zuo, Jian [Department of Developmental Neurobiology, St. Jude Children’s Research Hospital, Memphis, Tennessee (United States); Applegate, Brian E. [Department of Biomedical Engineering, Texas A& M University, College Station, Texas (United States)

    2015-12-31

    Normal mammalian hearing requires cochlear outer hair cell active processes that amplify the traveling wave with high gain and sharp tuning, termed cochlear amplification. We have used optical coherence tomography to study cochlear amplification within the apical turn of the mouse cochlea. We measured not only classical basilar membrane vibratory tuning curves but also vibratory responses from the rest of the tissues that compose the organ of Corti. Basilar membrane tuning was sharp in live mice and broad in dead mice, whereas other regions of the organ of Corti demonstrated phase shifts consistent with additional filtering beyond that provided by basilar membrane mechanics. We use these experimental data to support a conceptual framework of how cochlear amplification is tuned within the mouse cochlear apex. We will also study transgenic mice with targeted mutations that affect different biomechanical aspects of the organ of Corti in an effort to localize the underlying processes that produce this additional filtering.

  11. The Hearing Outcomes of Cochlear Implantation in Waardenburg Syndrome.

    Science.gov (United States)

    Koyama, Hajime; Kashio, Akinori; Sakata, Aki; Tsutsumiuchi, Katsuhiro; Matsumoto, Yu; Karino, Shotaro; Kakigi, Akinobu; Iwasaki, Shinichi; Yamasoba, Tatsuya

    2016-01-01

    Objectives. This study aimed to determine the feasibility of cochlear implantation for sensorineural hearing loss in patients with Waardenburg syndrome. Method. A retrospective chart review was performed on patients who underwent cochlear implantation at the University of Tokyo Hospital. Clinical classification, genetic mutation, clinical course, preoperative hearing threshold, high-resolution computed tomography of the temporal bone, and postoperative hearing outcome were assessed. Result. Five children with Waardenburg syndrome underwent cochlear implantation. The average age at implantation was 2 years 11 months (ranging from 1 year 9 months to 6 years 3 months). Four patients had congenital profound hearing loss and one patient had progressive hearing loss. Two patients had an inner ear malformation of cochlear incomplete partition type 2. No surgical complication or difficulty was seen in any patient. All patients showed good hearing outcome postoperatively. Conclusion. Cochlear implantation could be a good treatment option for Waardenburg syndrome.

  12. The Hearing Outcomes of Cochlear Implantation in Waardenburg Syndrome

    Directory of Open Access Journals (Sweden)

    Hajime Koyama

    2016-01-01

    Full Text Available Objectives. This study aimed to determine the feasibility of cochlear implantation for sensorineural hearing loss in patients with Waardenburg syndrome. Method. A retrospective chart review was performed on patients who underwent cochlear implantation at the University of Tokyo Hospital. Clinical classification, genetic mutation, clinical course, preoperative hearing threshold, high-resolution computed tomography of the temporal bone, and postoperative hearing outcome were assessed. Result. Five children with Waardenburg syndrome underwent cochlear implantation. The average age at implantation was 2 years 11 months (ranging from 1 year 9 months to 6 years 3 months. Four patients had congenital profound hearing loss and one patient had progressive hearing loss. Two patients had an inner ear malformation of cochlear incomplete partition type 2. No surgical complication or difficulty was seen in any patient. All patients showed good hearing outcome postoperatively. Conclusion. Cochlear implantation could be a good treatment option for Waardenburg syndrome.

  13. Gain and frequency tuning within the mouse cochlear apex

    International Nuclear Information System (INIS)

    Oghalai, John S.; Raphael, Patrick D.; Gao, Simon; Lee, Hee Yoon; Groves, Andrew K.; Zuo, Jian; Applegate, Brian E.

    2015-01-01

    Normal mammalian hearing requires cochlear outer hair cell active processes that amplify the traveling wave with high gain and sharp tuning, termed cochlear amplification. We have used optical coherence tomography to study cochlear amplification within the apical turn of the mouse cochlea. We measured not only classical basilar membrane vibratory tuning curves but also vibratory responses from the rest of the tissues that compose the organ of Corti. Basilar membrane tuning was sharp in live mice and broad in dead mice, whereas other regions of the organ of Corti demonstrated phase shifts consistent with additional filtering beyond that provided by basilar membrane mechanics. We use these experimental data to support a conceptual framework of how cochlear amplification is tuned within the mouse cochlear apex. We will also study transgenic mice with targeted mutations that affect different biomechanical aspects of the organ of Corti in an effort to localize the underlying processes that produce this additional filtering

  14. An image guidance system for positioning robotic cochlear implant insertion tools

    Science.gov (United States)

    Bruns, Trevor L.; Webster, Robert J.

    2017-03-01

    Cochlear implants must be inserted carefully to avoid damaging the delicate anatomical structures of the inner ear. This has motivated several approaches to improve the safety and efficacy of electrode array insertion by automating the process with specialized robotic or manual insertion tools. When such tools are used, they must be positioned at the entry point to the cochlea and aligned with the desired entry vector. This paper presents an image guidance system capable of accurately positioning a cochlear implant insertion tool. An optical tracking system localizes the insertion tool in physical space while a graphical user interface incorporates this with patient- specific anatomical data to provide error information to the surgeon in real-time. Guided by this interface, novice users successfully aligned the tool with an mean accuracy of 0.31 mm.

  15. Facial nerve stimulation outcomes after cochlear implantation with cochlear-facial dehiscence

    Directory of Open Access Journals (Sweden)

    Christina H. Fang, MD

    2017-06-01

    Conclusion: Cochlear-facial dehiscence can predispose patients to post-implant FNS. Prior temporal bone irradiation may carry a higher risk of FNS. We recommend scrutiny for CFD in CTs of CI candidates and appropriate risk counseling for FNS if CFD is discovered and more frequent monitoring for FNS by audiology.

  16. The Society for Radiological Protection - 40 years on from 1963

    International Nuclear Information System (INIS)

    Dunster, H John

    2003-01-01

    The Society for Radiological Protection was created in 1963 at a time when the structure of radiological protection in the United Kingdom was already well established. From its creation 40 years ago to the present, most of the features of British radiological protection stem from the recommendations of the International Commission on Radiological Protection. This review of the development of radiological protection has been produced to celebrate the 40 years of the Society's support of radiological protection, both in the United Kingdom and internationally. (review)

  17. Radiological Protection Science and Application

    International Nuclear Information System (INIS)

    Janssens, Augustin; ); Mossman, Ken; Morgan, Bill

    2016-01-01

    Since the discovery of radiation at the end of the 19. century, the health effects of exposure to radiation have been studied more than almost any other factor with potential effects on human health. The NEA has long been involved in discussions on the effects of radiation exposure, releasing two reports in 1994 and 2007 on radiological protection science. This report is the third in this state-of-the-art series, examining recent advances in the understanding of radiation risks and effects, particularly at low doses. It focuses on radiobiology and epidemiology, and also addresses the social science aspects of stakeholder involvement in radiological protection decision making. The report summarises the status of, and issues arising from, the application of the International System of Radiological Protection to different types of prevailing circumstances. Reports published by the NEA Committee on Radiation Protection and Public Health (CRPPH) in 1998 and 2007 provided an overview of the scientific knowledge available at that time, as well as the expected results from further research. They also discussed the policy implications that these results could have for the radiological protection system. The 2007 report highlighted challenges posed by developments in relation to medical exposure and by intentions to include the environment (i.e. non-human species), within the scope of the radiological protection system. It also addressed the need to be able to respond to a radiological terrorist attack. This report picks up on where the 1998 and 2007 reports left off, and addresses the state of the art in radiological prevention science and application today. It is divided into five chapters. Firstly, following broadly the structural topics from the 1998 and 2007 reports, the more purely scientific aspects of radiological protection are presented. These include cancer risk of low dose and dose rates, non-cancer effects and individual sensitivity. In view of the increasing

  18. Educational treasures in Radiology: The Radiology Olympics - striving for gold in Radiology education

    OpenAIRE

    Talanow, Roland

    2010-01-01

    This article focuses on Radiology Olympics (www.RadiologyOlympics.com) - a collaboration with the international Radiology community for Radiology education, Radiolopolis (www.Radiolopolis.com). The Radiology Olympics honour the movers and shakers in Radiology education and offer an easy to use platform for educating medical professionals based on Radiology cases.

  19. Spatial channel interactions in cochlear implants

    Science.gov (United States)

    Tang, Qing; Benítez, Raul; Zeng, Fan-Gang

    2011-08-01

    The modern multi-channel cochlear implant is widely considered to be the most successful neural prosthesis owing to its ability to restore partial hearing to post-lingually deafened adults and to allow essentially normal language development in pre-lingually deafened children. However, the implant performance varies greatly in individuals and is still limited in background noise, tonal language understanding, and music perception. One main cause for the individual variability and the limited performance in cochlear implants is spatial channel interaction from the stimulating electrodes to the auditory nerve and brain. Here we systematically examined spatial channel interactions at the physical, physiological, and perceptual levels in the same five modern cochlear implant subjects. The physical interaction was examined using an electric field imaging technique, which measured the voltage distribution as a function of the electrode position in the cochlea in response to the stimulation of a single electrode. The physiological interaction was examined by recording electrically evoked compound action potentials as a function of the electrode position in response to the stimulation of the same single electrode position. The perceptual interactions were characterized by changes in detection threshold as well as loudness summation in response to in-phase or out-of-phase dual-electrode stimulation. To minimize potentially confounding effects of temporal factors on spatial channel interactions, stimulus rates were limited to 100 Hz or less in all measurements. Several quantitative channel interaction indexes were developed to define and compare the width, slope and symmetry of the spatial excitation patterns derived from these physical, physiological and perceptual measures. The electric field imaging data revealed a broad but uniformly asymmetrical intracochlear electric field pattern, with the apical side producing a wider half-width and shallower slope than the basal

  20. IAEA Perspectives on Radiological Characterisation

    International Nuclear Information System (INIS)

    O'Sullivan, Patrick; Ljubenov, Vladan

    2012-01-01

    Requirements for characterization of radiological and other hazards in nuclear facilities are reflected in the IAEA Safety Standards. WS-R-5, Safety Requirements for Decommissioning of Facilities using Radioactive Material, includes a requirement that 'During the preparation of the final decommissioning plan, the extent and type of radioactive material (irradiated and contaminated structures and components) at the facility shall be determined by means of a detailed characterization survey and on the basis of records collected during the operational period'. The subsidiary Safety Guide WS-G-2.1, Decommissioning of Nuclear Power Plants and Research Reactors, further elaborates that 'A survey of radiological and non-radiological hazards provides an important input for the safety assessment and for implementing a safe approach during the work'. Although the characterisation requirements addressed in the Safety Standards relate primarily to the detailed survey activities undertaken following the shutdown of the facility, it is evident that radiological characterization is of relevance to all major phases of the lifetime of a nuclear facility, including: - the siting phase - baseline surveys are undertaken to determine background radiation levels; - the construction phase - construction materials are retained to support future calculations of radioactivity distributions; - the operational phase - surveys are done regularly, with additional surveys being required following incidents involving plant contamination; - the transition phase - detailed radiological surveys are required to support the development of the final decommissioning plan; and - the closure phase - a final survey of the site and any remaining structures will be needed to support an application for release of the site from regulatory control. In the case of facilities that are already shut down, the main purpose of radiological characterisation is to provide a reliable database of information on the

  1. Chronic Conductive Hearing Loss Leads to Cochlear Degeneration.

    Science.gov (United States)

    Liberman, M Charles; Liberman, Leslie D; Maison, Stéphane F

    2015-01-01

    Synapses between cochlear nerve terminals and hair cells are the most vulnerable elements in the inner ear in both noise-induced and age-related hearing loss, and this neuropathy is exacerbated in the absence of efferent feedback from the olivocochlear bundle. If age-related loss is dominated by a lifetime of exposure to environmental sounds, reduction of acoustic drive to the inner ear might improve cochlear preservation throughout life. To test this, we removed the tympanic membrane unilaterally in one group of young adult mice, removed the olivocochlear bundle in another group and compared their cochlear function and innervation to age-matched controls one year later. Results showed that tympanic membrane removal, and the associated threshold elevation, was counterproductive: cochlear efferent innervation was dramatically reduced, especially the lateral olivocochlear terminals to the inner hair cell area, and there was a corresponding reduction in the number of cochlear nerve synapses. This loss led to a decrease in the amplitude of the suprathreshold cochlear neural responses. Similar results were seen in two cases with conductive hearing loss due to chronic otitis media. Outer hair cell death was increased only in ears lacking medial olivocochlear innervation following olivocochlear bundle cuts. Results suggest the novel ideas that 1) the olivocochlear efferent pathway has a dramatic use-dependent plasticity even in the adult ear and 2) a component of the lingering auditory processing disorder seen in humans after persistent middle-ear infections is cochlear in origin.

  2. Cadaveric feasibility study of da Vinci Si-assisted cochlear implant with augmented visual navigation for otologic surgery.

    Science.gov (United States)

    Liu, Wen P; Azizian, Mahdi; Sorger, Jonathan; Taylor, Russell H; Reilly, Brian K; Cleary, Kevin; Preciado, Diego

    2014-03-01

    To our knowledge, this is the first reported cadaveric feasibility study of a master-slave-assisted cochlear implant procedure in the otolaryngology-head and neck surgery field using the da Vinci Si system (da Vinci Surgical System; Intuitive Surgical, Inc). We describe the surgical workflow adaptations using a minimally invasive system and image guidance integrating intraoperative cone beam computed tomography through augmented reality. To test the feasibility of da Vinci Si-assisted cochlear implant surgery with augmented reality, with visualization of critical structures and facilitation with precise cochleostomy for electrode insertion. Cadaveric case study of bilateral cochlear implant approaches conducted at Intuitive Surgical Inc, Sunnyvale, California. Bilateral cadaveric mastoidectomies, posterior tympanostomies, and cochleostomies were performed using the da Vinci Si system on a single adult human donor cadaveric specimen. Radiographic confirmation of successful cochleostomies, placement of a phantom cochlear implant wire, and visual confirmation of critical anatomic structures (facial nerve, cochlea, and round window) in augmented stereoendoscopy. With a surgical mean time of 160 minutes per side, complete bilateral cochlear implant procedures were successfully performed with no violation of critical structures, notably the facial nerve, chorda tympani, sigmoid sinus, dura, or ossicles. Augmented reality image overlay of the facial nerve, round window position, and basal turn of the cochlea was precise. Postoperative cone beam computed tomography scans confirmed successful placement of the phantom implant electrode array into the basal turn of the cochlea. To our knowledge, this is the first study in the otolaryngology-head and neck surgery literature examining the use of master-slave-assisted cochleostomy with augmented reality for cochlear implants using the da Vinci Si system. The described system for cochleostomy has the potential to improve the

  3. Cochlear implants in children implanted in Jordan: A parental overview.

    Science.gov (United States)

    Alkhamra, Rana A

    2015-07-01

    Exploring the perspective of parents on the cochlear implant process in Jordan. Sixty parents of deaf children were surveyed on the information gathering process prior to cochlear implant surgery, and their implant outcome expectations post-surgery. Whether child or parent characteristics may impact parents' post-surgical expectations was explored. Although parents used a variety of information sources when considering a cochlear implant, the ear, nose and throat doctor comprised their major source of information (60%). Parents received a range of information prior to cochlear implant but agreed (93.3%) on the need for a multidisciplinary team approach. Post-surgically, parents' expected major developments in the areas of spoken language (97%), and auditory skills (100%). Receiving education in mainstream schools (92%) was expected too. Parents perceived the cochlear implant decision as the best decision they can make for their child (98.3%). A significant correlation was found between parents contentment with the cochlear implant decision and expecting developments in the area of reading and writing (r=0.7). Child's age at implantation and age at hearing loss diagnosis significantly affected parents' post-implant outcome expectations (pparents agree on the need for a comprehensive multidisciplinary team approach during the different stages of the cochlear implant process. Parents' education about cochlear implants prior to the surgery can affect their post-surgical outcome expectations. The parental perspective presented in this study can help professionals develop better understanding of parents' needs and expectations and henceforth improve their services and support during the different stages of the cochlear implant process. Copyright © 2015. Published by Elsevier Ireland Ltd.

  4. Qualitative case studies of five cochlear implant recipients' experience with music.

    Science.gov (United States)

    Bartel, Lee R; Greenberg, Simon; Friesen, Lendra M; Ostroff, Jodi; Bodmer, Daniel; Shipp, David; Chen, Joseph M

    2011-02-01

    Cochlear implantation has revolutionized the management of those who suffer from severe-to-profound hearing loss because many patients now achieve excellent speech understanding with objective testing. Nevertheless, speech understanding in noisy conditions and music appreciation remain significant challenges to cochlear implant (CI) users. Music appreciation is an extremely complex experience that is difficult to quantify through a conventional outcome study. This paper aims at documenting the experience of five CI patients with regard to music appreciation using qualitative techniques. This information was obtained through a semi-structured interview process. The interviews were then transcribed and analysed using a constant comparative method of qualitative description. The results together with medical case records were used to identify emerging themes. The common themes that evolved were: musical background, the experience of receiving the implant, current experience with music, attention, musical prediction ability, internal hearing, hedonic vs. critical listening, determination, and timbre perception. By documenting their experiences in this manner, novel insights into the patient perspective are provided that are unique to the literature. These descriptions will aid clinicians and researchers who work in the area of cochlear implantation to better understand the needs of their patients.

  5. Hearing preservation cochlear implantation in children: The HEARRING Group consensus and practice guide.

    Science.gov (United States)

    Rajan, Gunesh; Tavora-Vieira, Dayse; Baumgartner, Wolf-Dieter; Godey, Benoit; Müller, Joachim; O'Driscoll, Martin; Skarzynski, Henryk; Skarzynski, Piotr; Usami, Shin-Ichi; Adunka, Oliver; Agrawal, Sumit; Bruce, Iain; De Bodt, Marc; Caversaccio, Marco; Pilsbury, Harold; Gavilán, Javier; Hagen, Rudolf; Hagr, Abdulrahman; Kameswaran, Mohan; Karltorp, Eva; Kompis, Martin; Kuzovkov, Vlad; Lassaletta, Luis; Yongxin, Li; Lorens, Artur; Manoj, Manikoth; Martin, Jane; Mertens, Griet; Mlynski, Robert; Parnes, Lorne; Pulibalathingal, Sasidharan; Radeloff, Andreas; Raine, Christopher H; Rajeswaran, Ranjith; Schmutzhard, Joachim; Sprinzl, Georg; Staecker, Hinrich; Stephan, Kurt; Sugarova, Serafima; Zernotti, Mario; Zorowka, Patrick; Van de Heyning, Paul

    2018-01-01

    To provide multidisciplinary cochlear implant teams with a current consensus statement to support hearing preservation cochlear implantation (HPCI) in children, including those children with symptomatic partial deafness (PD) where the intention is to use electric-acoustic stimulation (EAS). The main objectives are to provide guidelines on who is a candidate, how to assess these children and when to implant if Med-El Flex electrode arrays are chosen for implantation. The HEARRING group reviewed the current evidence and practice regarding the management of children to be considered for HPCI surgery emphasizing the assessment needed prior to implantation in order to demonstrate the benefits in these children over time. The consensus statement addresses following three key questions: (1) Should these children be treated? (2) How to identify these children? (3) How to manage these children? The HEARRING group concludes that irrespective of the degree of residual hearing present, the concepts of hearing and structure preservation should be applied in every child undergoing cochlear implantation and that HPCI is a safe and reliable treatment option. Early detection and multidisciplinary assessment are key to the identification of children with symptomatic PD, these children should undergo HPCI as early as possible.

  6. Radiology trainer. Musculoskeletal system

    International Nuclear Information System (INIS)

    Staebler, A.; Erlt-Wagner, B.

    2006-01-01

    This book enables students to simulate examinations. The Radiology Trainer series comprises the whole knowledge of radiology in the form of case studies for self-testing. It is based on the best-sorted German-language collection of radiological examinations of all organ regions. Step by step, radiological knowledge is trained in order to make diagnoses more efficient. The book series ensures optimal preparation for the final medical examinations and is also a valuable tool for practical training. (orig.)

  7. Effects of maternal sensitivity and cognitive and linguistic stimulation on cochlear implant users' language development over four years.

    Science.gov (United States)

    Quittner, Alexandra L; Cruz, Ivette; Barker, David H; Tobey, Emily; Eisenberg, Laurie S; Niparko, John K

    2013-02-01

    To examine the effects of observed maternal sensitivity (MS), cognitive stimulation (CS), and linguistic stimulation on the 4-year growth of oral language in young, deaf children receiving a cochlear implant. Previous studies of cochlear implants have not considered the effects of parental behaviors on language outcomes. In this prospective, multisite study, we evaluated parent-child interactions during structured and unstructured play tasks and their effects on oral language development in 188 deaf children receiving a cochlear implant and 97 normal-hearing children as controls. Parent-child interactions were rated on a 7-point scale using the National Institute of Child Health and Human Development's Early Childcare Study codes, which have well-established psychometric properties. Language was assessed using the MacArthur Bates Communicative Development Inventories, the Reynell Developmental Language Scales, and the Comprehensive Assessment of Spoken Language. We used mixed longitudinal modeling to test our hypotheses. After accounting for early hearing experience and child and family demographics, MS and CS predicted significant increases in the growth of oral language. Linguistic stimulation was related to language growth only in the context of high MS. The magnitude of effects of MS and CS on the growth of language was similar to that found for age at cochlear implantation, suggesting that addressing parenting behaviors is a critical target for early language learning after implantation. Copyright © 2013 Mosby, Inc. All rights reserved.

  8. Radiological instrument

    International Nuclear Information System (INIS)

    Kronenberg, S.; McLaughlin, W.L.; Seibentritt, C.R. Jr.

    1986-01-01

    An instrument is described for measuring radiation, particularly nuclear radiation, comprising: a radiation sensitive structure pivoted toward one end and including a pair of elongated solid members contiguously joined together along their length dimensions and having a common planar interface therebetween. One of the pairs of members is comprised of radiochromic material whose index of refraction changes due to anomolous dispersion as a result of being exposed to nuclear radiation. The pair of members further has mutually different indices of refraction with the member having the larger index of refraction further being transparent for the passage of light and of energy therethrough; means located toward the other end of the structure for varying the angle of longitudinal elevation of the pair of members; means for generating and projecting a beam of light into one end of the member having the larger index of refraction. The beam of light is projected toward the planar interface where it is reflected out of the other end of the same member as a first output beam; means projecting a portion of the beam of light into one end of the member having the larger index of refraction where it traverses therethrough without reflection and out of the other end of the same member as a second output beam; and means adjacent the structure for receiving the first and second output beams, whereby a calibrated change in the angle of elevation of the structure between positions of equal intensity of the first and second output beams prior to and following exposure provides a measure of the radiation sensed due to a change of refraction of the radiochromic material

  9. Optimizing the structure and function of the 50-plus radiology organizations, part 2: a unified strategic plan-a summary of the 2011 Intersociety Conference.

    Science.gov (United States)

    Dodd, Gerald D

    2012-05-01

    The member organizations of the Intersociety Conference have agreed that radiology would benefit from consolidation and collaboration of the 50-plus radiology organizations. At this year's annual meeting, the participants concluded that the educational and research missions of the organizations would benefit from the creation of a unified strategic plan that addressed the coordination of annual meetings, online educational materials, research infrastructure, and the creation of a direct relationship between the research initiatives of the organizations and the patient advocacy groups of the Academy of Radiology Research. The socioeconomic mission of the organizations would be enhanced through the creation of a formal communication network with the ACR, and certification could be enhanced by the orchestration of the creation of educational materials related to the maintenance of certification. Copyright © 2012 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  10. Trends in Intraoperative Testing During Cochlear Implantation.

    Science.gov (United States)

    Page, Joshua Cody; Cox, Matthew D; Hollowoa, Blake; Bonilla-Velez, Juliana; Trinidade, Aaron; Dornhoffer, John L

    2018-03-01

    No consensus guidelines exist regarding intraoperative testing during cochlear implantation and wide variation in practice habits exists. The objective of this observational study was to survey otologists/neurotologists to understand practice habits and overall opinion of usefulness of intraoperative testing. Cross-sectional survey. A web-based survey was sent to 194 practicing Otologists/Neurotologists. Questions included practice setting and experience, habits with respect to electrodes used, intraoperative testing modalities used, overall opinion of intraoperative testing, and practice habits in various scenarios. Thirty-nine of 194 (20%) completed the survey. For routine patients, ECAPs and EIs were most commonly used together (38%) while 33% do not perform testing at all. Eighty-nine percent note that testing "rarely" or "never" changes management. Fifty-one percent marked the most important reason for testing is the reassurance provided to the family and/or the surgeon. Intraoperative testing habits and opinions regarding testing during cochlear implantation vary widely among otologic surgeons. The majority of surgeons use testing but many think there is minimal benefit and that surgical decision-making is rarely impacted. The importance of testing may change as electrodes continue to evolve.

  11. Hearing Preservation after Cochlear Implantation: UNICAMP Outcomes

    Directory of Open Access Journals (Sweden)

    Guilherme Machado de Carvalho

    2013-01-01

    Full Text Available Background. Electric-acoustic stimulation (EAS is an excellent choice for people with residual hearing in low frequencies but not high frequencies and who derive insufficient benefit from hearing aids. For EAS to be effective, subjects' residual hearing must be preserved during cochlear implant (CI surgery. Methods. We implanted 6 subjects with a CI. We used a special surgical technique and an electrode designed to be atraumatic. Subjects' rates of residual hearing preservation were measured 3 times postoperatively, lastly after at least a year of implant experience. Subjects' aided speech perception was tested pre- and postoperatively with a sentence test in quiet. Subjects' subjective responses assessed after a year of EAS or CI experience. Results. 4 subjects had total or partial residual hearing preservation; 2 subjects had total residual hearing loss. All subjects' hearing and speech perception benefited from cochlear implantation. CI diminished or eliminated tinnitus in all 4 subjects who had it preoperatively. 5 subjects reported great satisfaction with their new device. Conclusions. When we have more experience with our surgical technique we are confident we will be able to report increased rates of residual hearing preservation. Hopefully, our study will raise the profile of EAS in Brazil and Latin/South America.

  12. Radiology systems architecture.

    Science.gov (United States)

    Deibel, S R; Greenes, R A

    1996-05-01

    This article focuses on the software requirements for enterprise integration in radiology. The needs of a future radiology systems architecture are examined, both at a concrete functional level and at an abstract system-properties level. A component-based approach to software development is described and is validated in the context of each of the abstract system requirements for future radiology computing environments.

  13. Reduction in spread of excitation from current focusing at multiple cochlear locations in cochlear implant users.

    Science.gov (United States)

    Padilla, Monica; Landsberger, David M

    2016-03-01

    Channel interaction from a broad spread of excitation is likely to be a limiting factor in performance by cochlear implant users. Although partial tripolar stimulation has been shown to reduce spread of excitation, the magnitude of the reduction is highly variable across subjects. Because the reduction in spread of excitation is typically only measured at one electrode for a given subject, the degree of variability across cochlear locations is unknown. The first goal of the present study was to determine if the reduction in spread of excitation observed from partial tripolar current focusing systematically varies across the cochlea. The second goal was to measure the variability in reduction of spread of excitation relative to monopolar stimulation across the cochlea. The third goal was to expand upon previous results that suggest that scaling of verbal descriptors can be used to predict the reduction in spread of excitation, by increasing the limited number of sites previously evaluated and verify the relationships remain with the larger dataset. The spread of excitation for monopolar and partial tripolar stimulation was measured at 5 cochlear locations using a psychophysical forward masking task. Results of the present study suggest that although partial tripolar stimulation typically reduces spread of excitation, the degree of reduction in spread of excitation was found to be highly variable and no effect of cochlear location was found. Additionally, subjective scaling of certain verbal descriptors (Clean/Dirty, Pure/Noisy) correlated with the reduction in spread of excitation suggesting sound quality scaling might be used as a quick clinical estimate of channels providing a reduction in spread of excitation. This quick scaling technique might help clinicians determine which patients would be most likely to benefit from a focused strategy. Copyright © 2016 Elsevier B.V. All rights reserved.

  14. The long-term concerns post cochlear implantation as experienced ...

    African Journals Online (AJOL)

    quality of life of families with children who have a hearing loss or who are fitted with cochlear implants. .... term going into the work force with a severe disability will he be .... balance between professional caution and urgency of treatment.

  15. Cochlear Implants Keep Twin Sisters Learning, Discovering Together

    Science.gov (United States)

    ... Current Issue Past Issues Special Section: Focus on Communication Cochlear Implants Past Issues / Fall 2008 Table of ... in noisy environments—a critical ability in a classroom. Before the second implant, Mia was pulling back ...

  16. Planning new basic guideline to the radiological risk. Content, radiological criteria and implementation

    International Nuclear Information System (INIS)

    Calvin Cuartero, M.; Vega Riber, R. de la; Martin Calvarro, J. M.

    2011-01-01

    The most important aspects of the Basic Guideline focus on their area of planning, groups of potential radiological emergencies in the type of activity associated with the levels of response planning and responsible organizations, structure and functions for each level, radiological criteria, implementation and maintenance of the effectiveness of the level of response plans abroad.

  17. Radiology and fine art.

    Science.gov (United States)

    Marinković, Slobodan; Stošić-Opinćal, Tatjana; Tomić, Oliver

    2012-07-01

    The radiologic aesthetics of some body parts and internal organs have inspired certain artists to create specific works of art. Our aim was to describe the link between radiology and fine art. We explored 13,625 artworks in the literature produced by 2049 artists and found several thousand photographs in an online image search. The examination revealed 271 radiologic artworks (1.99%) created by 59 artists (2.88%) who mainly applied radiography, sonography, CT, and MRI. Some authors produced radiologic artistic photographs, and others used radiologic images to create artful compositions, specific sculptures, or digital works. Many radiologic artworks have symbolic, metaphoric, or conceptual connotations. Radiology is clearly becoming an original and important field of modern art.

  18. COCHLEAR IMPLANTATION IN A PATIENT WITH USHER'S SYNDROME

    OpenAIRE

    Derinsu, Ufuk; Ciprut, Ayca

    2016-01-01

    Usher's Syndrome is an autosomal recessive disorder characterized by congenital hearing loss and retinitis pigmentosa. Usher’s Syndrome patients with severe to profound sensorineural hearing loss can be considered as candidates for cochlear implantation.This case study reports a deaf-blind with Usher's Syndrome who received a cochlear implant, the audiological evaluation is presented and the therapy sessions are discussed. The patient demonstrated good performance overtime after the...

  19. Language understanding and vocabulary of early cochlear implanted children

    DEFF Research Database (Denmark)

    Percy-Smith, L; Busch, GW; Sandahl, M

    2013-01-01

    The aim of the study was to identify factors associated with the level of language understanding, the level of receptive and active vocabulary, and to estimate effect-related odds ratios for cochlear implanted children's language level.......The aim of the study was to identify factors associated with the level of language understanding, the level of receptive and active vocabulary, and to estimate effect-related odds ratios for cochlear implanted children's language level....

  20. Computational tool for postoperative evaluation of cochlear implant patients

    International Nuclear Information System (INIS)

    Giacomini, Guilherme; Pavan, Ana Luiza M.; Pina, Diana R. de; Altemani, Joao M.C.; Castilho, Arthur M.

    2016-01-01

    The aim of this study was to develop a tool to calculate the insertion depth angle of cochlear implants, from computed tomography exams. The tool uses different image processing techniques, such as thresholding and active contour. Then, we compared the average insertion depth angle of three different implant manufacturers. The developed tool can be used, in the future, to compare the insertion depth angle of the cochlear implant with postoperative response of patient's hearing. (author)

  1. Cochlear implantation in the Mondini inner ear malformation.

    Science.gov (United States)

    Miyamoto, R T; Robbins, A J; Myres, W A; Pope, M L

    1986-07-01

    We report the case of a profoundly deaf 4-year-old boy with congenital deafness as a result of Mondini's dysplasia. The Mondini inner ear malformation is the result of arrested labyrinthine development during embryogenesis and is characterized by both bony and membranous anomalies of the inner ear. The dysplastic cochlear anatomy does not preclude successful cochlear implantation, and electrical threshold measurements are similar to those recorded in pediatric subjects deafened as a result of other causes.

  2. Psycholinguistic abilities in cochlear implant and hearing impaired children

    OpenAIRE

    Hassan, Hatem Ezzeldin; Eldin, Sally Taher Kheir; Al Kasaby, Rasha Mohamed

    2014-01-01

    Background: Many congenitally sensorineural hearing loss (SNHL) children and cochlear implant (CI) recipients develop near-normal language skills. However, there is a wide variation in individual outcomes following cochlear implantation, or using hearing aids. Some CI recipients or Hearing aids users never develop useable speech and oral language skills. The causes of this enormous variation in outcomes are only partly understood at the present time. So, the aim of this study was to assess th...

  3. The Hearing Outcomes of Cochlear Implantation in Waardenburg Syndrome

    OpenAIRE

    Koyama, Hajime; Kashio, Akinori; Sakata, Aki; Tsutsumiuchi, Katsuhiro; Matsumoto, Yu; Karino, Shotaro; Kakigi, Akinobu; Iwasaki, Shinichi; Yamasoba, Tatsuya

    2016-01-01

    Objectives. This study aimed to determine the feasibility of cochlear implantation for sensorineural hearing loss in patients with Waardenburg syndrome. Method. A retrospective chart review was performed on patients who underwent cochlear implantation at the University of Tokyo Hospital. Clinical classification, genetic mutation, clinical course, preoperative hearing threshold, high-resolution computed tomography of the temporal bone, and postoperative hearing outcome were assessed. Result. F...

  4. Characterization of Cochlear, Vestibular and Cochlear-Vestibular Electrically Evoked Compound Action Potentials in Patients with a Vestibulo-Cochlear Implant

    Directory of Open Access Journals (Sweden)

    T. A. K. Nguyen

    2017-11-01

    Full Text Available The peripheral vestibular system is critical for the execution of activities of daily life as it provides movement and orientation information to motor and sensory systems. Patients with bilateral vestibular hypofunction experience a significant decrease in quality of life and have currently no viable treatment option. Vestibular implants could eventually restore vestibular function. Most vestibular implant prototypes to date are modified cochlear implants to fast-track development. These use various objective measurements, such as the electrically evoked compound action potential (eCAP, to supplement behavioral information. We investigated whether eCAPs could be recorded in patients with a vestibulo-cochlear implant. Specifically, eCAPs were successfully recorded for cochlear and vestibular setups, as well as for mixed cochlear-vestibular setups. Similarities and slight differences were found for the recordings of the three setups. These findings demonstrated the feasibility of eCAP recording with a vestibulo-cochlear implant. They could be used in the short term to reduce current spread and avoid activation of non-targeted neurons. More research is warranted to better understand the neural origin of vestibular eCAPs and to utilize them for clinical applications.

  5. Bilateral Cochlear Implants: Maximizing Expected Outcomes.

    Science.gov (United States)

    Wallis, Kate E; Blum, Nathan J; Waryasz, Stephanie A; Augustyn, Marilyn

    Sonia is a 4 years 1 month-year-old girl with Waardenburg syndrome and bilateral sensorineural hearing loss who had bilateral cochlear implants at 2 years 7 months years of age. She is referred to Developmental-Behavioral Pediatrics by her speech/language pathologist because of concerns that her language skills are not progressing as expected after the cochlear implant. At the time of the implant, she communicated using approximately 20 signs and 1 spoken word (mama). At the time of the evaluation (18 months after the implant) she had approximately 70 spoken words (English and Spanish) and innumerable signs that she used to communicate. She could follow 1-step directions in English but had more difficulty after 2-step directions.Sonia was born in Puerto Rico at 40 weeks gestation after an uncomplicated pregnancy. She failed her newborn hearing test and was given hearing aids that did not seem to help.At age 2 years, Sonia, her mother, and younger sister moved to the United States where she was diagnosed with bilateral severe-to-profound hearing loss. Genetic testing led to a diagnosis of Waardenburg syndrome (group of genetic conditions that can cause hearing loss and changes in coloring [pigmentation] of the hair, skin, and eyes). She received bilateral cochlear implants 6 months later.Sonia's mother is primarily Spanish-speaking and mostly communicates with her in Spanish or with gestures but has recently begun to learn American Sign Language (ASL). In a preschool program at a specialized school for the deaf, Sonia is learning both English and ASL. Sonia seems to prefer to use ASL to communicate.Sonia receives speech and language therapy (SLT) 3 times per week (90 minutes total) individually in school and once per week within a group. She is also receiving outpatient SLT once per week. Therapy sessions are completed in English, with the aid of an ASL interpreter. Sonia's language scores remain low, with her receptive skills in the first percentile, and her

  6. [Cochlear implantation in patients with Waardenburg syndrome type II].

    Science.gov (United States)

    Wan, Liangcai; Guo, Menghe; Chen, Shuaijun; Liu, Shuangriu; Chen, Hao; Gong, Jian

    2010-05-01

    To describe the multi-channel cochlear implantation in patients with Waardenburg syndrome including surgeries, pre and postoperative hearing assessments as well as outcomes of speech recognition. Multi-channel cochlear implantation surgeries have been performed in 12 cases with Waardenburg syndrome type II in our department from 2000 to 2008. All the patients received multi-channel cochlear implantation through transmastoid facial recess approach. The postoperative outcomes of 12 cases were compared with 12 cases with no inner ear malformation as a control group. The electrodes were totally inserted into the cochlear successfully, there was no facial paralysis and cerebrospinal fluid leakage occurred after operation. The hearing threshold in this series were similar to that of the normal cochlear implantation. After more than half a year of speech rehabilitation, the abilities of speech discrimination and spoken language of all the patients were improved compared with that of preoperation. Multi-channel cochlear implantation could be performed in the cases with Waardenburg syndrome, preoperative hearing and images assessments should be done.

  7. Production of verb tenses in children with cochlear implants

    Directory of Open Access Journals (Sweden)

    Sokolovac Ivana

    2016-01-01

    Full Text Available The production of verb tenses leads to better language development of children with cochlear implants. The aim of this study was to assess the acquisition of verb tenses in children with cochlear implants. The sample included 60 children, aged from 9 to 15, with average intellectual abilities. The study group consisted of 30 patients with cochlear implants, with no additional disabilities. The control group consisted of 30 subjects with typical speech - language development and preserved hearing. The acquisition of basic tenses was assessed by 'Corpus for the Assessment of the Use of Tenses' (Dimić, 2003. Significant statistical differences were found in the use of the present tense in children with cochlear implants and hearing children (t=-4.385; p<0.001 as well as in the use of the past tense (t=-4.650; p<0.001, and the future tense (t=-4.269; p<0.001. There was also a significant difference in the use of irregular verb 'go' (t=-3.958; p<0.001, as well as in the combination of the present and the past tense (t=-5.806; p<0.001. The present tense was used correctly by most children with cochlear implants (70%, followed by the past tense (53%, and finally the future tense (23%. Children with cochlear implants, even after several years of re/habilitation, do not reach the grammatical development of children with normal hearing.

  8. United Kingdom national paediatric bilateral cochlear implant audit: preliminary results.

    Science.gov (United States)

    Cullington, Helen; Bele, Devyanee; Brinton, Julie; Lutman, Mark

    2013-11-01

    Prior to 2009, United Kingdom (UK) public funding was mainly only available for children to receive unilateral cochlear implants. In 2009, the National Institute for Health and Care Excellence published guidance for cochlear implantation following their review. According to these guidelines, all suitable children are eligible to have simultaneous bilateral cochlear implants or a sequential bilateral cochlear implant if they had received the first before the guidelines were published. Fifteen UK cochlear implant centres formed a consortium to carry out a multi-centre audit. The audit involves collecting data from simultaneously and sequentially implanted children at four intervals: before bilateral cochlear implants or before the sequential implant, 1, 2, and 3 years after bilateral implants. The measures include localization, speech recognition in quiet and background noise, speech production, listening, vocabulary, parental perception, quality of life, and surgical data including complications. The audit has now passed the 2-year point, and data have been received on 850 children. This article provides a first view of some data received up until March 2012.

  9. Cochlear implantation for single-sided deafness and tinnitus suppression.

    Science.gov (United States)

    Holder, Jourdan T; O'Connell, Brendan; Hedley-Williams, Andrea; Wanna, George

    To quantify the potential effectiveness of cochlear implantation for tinnitus suppression in patients with single-sided deafness using the Tinnitus Handicap Inventory. The study included 12 patients with unilateral tinnitus who were undergoing cochlear implantation for single-sided deafness. The Tinnitus Handicap Inventory was administered at the patient's cochlear implant candidacy evaluation appointment prior to implantation and every cochlear implant follow-up appointment, except activation, following implantation. Patient demographics and speech recognition scores were also retrospectively recorded using the electronic medical record. A significant reduction was found when comparing Tinnitus Handicap Inventory score preoperatively (61.2±27.5) to the Tinnitus Handicap Inventory score after three months of cochlear implant use (24.6±28.2, p=0.004) and the Tinnitus Handicap Inventory score beyond 6months of CI use (13.3±18.9, p=0.008). Further, 45% of patients reported total tinnitus suppression. Mean CNC word recognition score improved from 2.9% (SD 9.4) pre-operatively to 40.8% (SD 31.7) by 6months post-activation, which was significantly improved from pre-operative scores (p=0.008). The present data is in agreement with previously published studies that have shown an improvement in tinnitus following cochlear implantation for the large majority of patients with single-sided deafness. Copyright © 2017 Elsevier Inc. All rights reserved.

  10. Occupational radiological protection in diagnostic radiology

    International Nuclear Information System (INIS)

    Mota, H.C.

    1983-01-01

    The following topics are discussed: occupational expossure (the ALARA principle, dose-equivalent limit, ICRP justification); radiological protection planning (general aspects, barrier estimation) and determination of the occupational expossures (individual monitoring). (M.A.) [pt

  11. Radiology of oesophageal dysphagia

    International Nuclear Information System (INIS)

    Phillips, A.J.; Nolan, D.J.

    1995-01-01

    Dysphagia is defined as the sensation of difficulty in swallowing. The causes of dysphagia can be oropharyngeal or oesophageal. Oesophageal dysphagia develops as a result of mechanical obstruction or motility disorders and frequently causes distressing symptoms. Patients who develop oesophageal dysphagia can be easily and rapidly examined by routine barium techniques. The barium swallow remains a safe, accurate and widely available method for showing structural and functional oesophageal lesions, and for identifying those patients who require urgent endoscopic assessment and treatment. Computed tomography (CT), magnetic resonance imaging (MRI)) and endoscopic ultrasonography are available for the preoperative staging of oesophageal neoplasms. This article discusses the radiological appearances of the main oesophageal disorders that cause dysphagia in adults. (author). 15 refs., 20 figs., 1 tab

  12. Radiology in Medical Education: A Pediatric Radiology Elective as a Template for Other Radiology Courses.

    Science.gov (United States)

    Hilmes, Melissa A; Hyatt, Eddie; Penrod, Cody H; Fleming, Amy E; Singh, Sudha P

    2016-03-01

    Traditionally, the pediatric radiology elective for medical students and pediatric residents constituted a morning teaching session focused mainly on radiography and fluoroscopy. A more structured elective was desired to broaden the exposure to more imaging modalities, create a more uniform educational experience, and include assessment tools. In 2012, an introductory e-mail and formal syllabus, including required reading assignments, were sent to participants before the start date. A rotating weekly schedule was expanded to include cross-sectional imaging (ultrasound, CT, MR) and nuclear medicine. The schedule could accommodate specific goals of the pediatric resident or medical student, as requested. Starting in 2013, an online pre-test and post-test were developed, as well as an online end-of-rotation survey specific to the pediatric radiology elective. Taking the Image Gently pledge was required. A scavenger hunt tool, cue cards, and electronic modules were added. Pre-test and post-test scores, averaged over 2 years, showed improvement in radiology knowledge, with scores increasing by 27% for medical students and 21% for pediatric residents. Surveys at the end of the elective were overwhelmingly positive, with constructive criticism and complimentary comments. We have successfully created an elective experience in radiology that dedicates time to education while preserving the workflow of radiologists. We have developed tools to provide a customized experience with many self-directed learning opportunities. Our tools and techniques are easily translatable to a general or adult radiology elective. Copyright © 2016 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  13. Binaural enhancement for bilateral cochlear implant users.

    Science.gov (United States)

    Brown, Christopher A

    2014-01-01

    Bilateral cochlear implant (BCI) users receive limited binaural cues and, thus, show little improvement to speech intelligibility from spatial cues. The feasibility of a method for enhancing the binaural cues available to BCI users is investigated. This involved extending interaural differences of levels, which typically are restricted to high frequencies, into the low-frequency region. Speech intelligibility was measured in BCI users listening over headphones and with direct stimulation, with a target talker presented to one side of the head in the presence of a masker talker on the other side. Spatial separation was achieved by applying either naturally occurring binaural cues or enhanced cues. In this listening configuration, BCI patients showed greater speech intelligibility with the enhanced binaural cues than with naturally occurring binaural cues. In some situations, it is possible for BCI users to achieve greater speech intelligibility when binaural cues are enhanced by applying interaural differences of levels in the low-frequency region.

  14. Accurate guitar tuning by cochlear implant musicians.

    Directory of Open Access Journals (Sweden)

    Thomas Lu

    Full Text Available Modern cochlear implant (CI users understand speech but find difficulty in music appreciation due to poor pitch perception. Still, some deaf musicians continue to perform with their CI. Here we show unexpected results that CI musicians can reliably tune a guitar by CI alone and, under controlled conditions, match simultaneously presented tones to <0.5 Hz. One subject had normal contralateral hearing and produced more accurate tuning with CI than his normal ear. To understand these counterintuitive findings, we presented tones sequentially and found that tuning error was larger at ∼ 30 Hz for both subjects. A third subject, a non-musician CI user with normal contralateral hearing, showed similar trends in performance between CI and normal hearing ears but with less precision. This difference, along with electric analysis, showed that accurate tuning was achieved by listening to beats rather than discriminating pitch, effectively turning a spectral task into a temporal discrimination task.

  15. Ultra-Wideband Transceivers for Cochlear Implants

    Directory of Open Access Journals (Sweden)

    Reisenzahn Alexander

    2005-01-01

    Full Text Available Ultra-wideband (UWB radio offers low power consumption, low power spectral density, high immunity against interference, and other benefits, not only for consumer electronics, but also for medical devices. A cochlear implant (CI is an electronic hearing apparatus, requiring a wireless link through human tissue. In this paper we propose an UWB link for a data rate of Mbps and a propagation distance up to 500 mm. Transmitters with step recovery diode and transistor pulse generators are proposed. Two types of antennas and their filter characteristics in the UWB spectrum will be discussed. An ultra-low-power back tunnel diode receiver prototype is described and compared with conventional detector receivers.

  16. Cochlear vertebral entrapment syndrome: a case report

    Energy Technology Data Exchange (ETDEWEB)

    Liu Chinghsiung; Lin Shinnkuang E-mail: sk1943@adm.cgmh.org.tw; Chang Yeujhy

    2001-11-01

    The authors describe a patient with isolated involvement of vestibulocochlear nerve by a huge vascular loop from vertebral dolichoectasia. No other neurological deficit was found except for unilateral hearing loss. Abnormal brainstem auditory evoked potential study indicated a retrocochlear lesion. The brain computed tomography (CT) and magnetic resonance imaging (MRI) studies demonstrated an abnormally enhanced vascular lesion impinged on the left porus acusticus with a displacement of the brainstem to the right. There was no infarction in the brainstem. A cerebral angiography demonstrated a megadolichoectatic horizontal loop at the intracranial portion of the left vertebral artery. There was no thrombus or atherosclerosis in the vertebrobasilar system. A mechanical compression by a vascular loop is the only possible pathogenesis for hearing loss. The authors diagnose this condition as cochlear vertebral entrapment syndrome.

  17. The cochlear nerve canal and internal auditory canal in children with normal cochlea but cochlear nerve deficiency

    Energy Technology Data Exchange (ETDEWEB)

    Yan, Fei; Li, Jianhong; Xian, Junfang; Wang, Zhenchang [Dept. of Radiology, Beijing Tongren Hospital, Capital Medical Univ., Beijing (China)], e-mail: cjr.wzhch@vip.163.com; Mo, Lingyan [Dept. of Otorhinolaryngology, Beijing Tongren Hospital, Capital Medical Univ., Beijing (China)

    2013-04-15

    Background: There is an increasing frequency of requests for cochlear implantation (CI) in deaf children and more detailed image information is necessary for selecting appropriate candidates. Cochlear nerve deficiency (CND) is a contraindication to CI. Magnetic resonance imaging (MRI) has been used to evaluate the integrity of the cochlear nerve. The abnormalities of the cochlear nerve canal (CNC) and internal auditory canal (IAC) have been reported to be associated with CND. Purpose: To correlate CNC manifestation, size, and IAC diameter on high-resolution CT (HRCT) with CND diagnosed by MRI in children. Material and Methods: HRCT images from 35 sensorineurally deaf children who had normal cochlea but bilateral or unilateral CND diagnosed by MRI were studied retrospectively. The CNC and IAC manifestation and size were assessed and correlated with CND. Results: CND was diagnosed by MRI in 54/70 ears (77.1%). Thirty-two ears had an absent cochlear nerve (59.3%), while 22 ears had a small cochlear nerve (40.7%). The CNC diameter was <1.5 mm in 36 ears (66.7%). The CNC diameter ranged between 1.5 and 2.0 mm in seven ears (13.0%) and was >2.0 mm in 11 ears (20.4%). The IAC diameter was <3.0 mm in 25 ears (46.3%) and >3.0 mm in 29 ears (53.7%). Conclusion: The hypoplastic CNC might be more highly indicative of CND than that of a narrow IAC.

  18. The cochlear nerve canal and internal auditory canal in children with normal cochlea but cochlear nerve deficiency

    International Nuclear Information System (INIS)

    Yan, Fei; Li, Jianhong; Xian, Junfang; Wang, Zhenchang; Mo, Lingyan

    2013-01-01

    Background: There is an increasing frequency of requests for cochlear implantation (CI) in deaf children and more detailed image information is necessary for selecting appropriate candidates. Cochlear nerve deficiency (CND) is a contraindication to CI. Magnetic resonance imaging (MRI) has been used to evaluate the integrity of the cochlear nerve. The abnormalities of the cochlear nerve canal (CNC) and internal auditory canal (IAC) have been reported to be associated with CND. Purpose: To correlate CNC manifestation, size, and IAC diameter on high-resolution CT (HRCT) with CND diagnosed by MRI in children. Material and Methods: HRCT images from 35 sensorineurally deaf children who had normal cochlea but bilateral or unilateral CND diagnosed by MRI were studied retrospectively. The CNC and IAC manifestation and size were assessed and correlated with CND. Results: CND was diagnosed by MRI in 54/70 ears (77.1%). Thirty-two ears had an absent cochlear nerve (59.3%), while 22 ears had a small cochlear nerve (40.7%). The CNC diameter was 2.0 mm in 11 ears (20.4%). The IAC diameter was 3.0 mm in 29 ears (53.7%). Conclusion: The hypoplastic CNC might be more highly indicative of CND than that of a narrow IAC

  19. [Cochlear implants in the social courts].

    Science.gov (United States)

    Lottner, A; Iro, H; Schützenberger, A; Hoppe, U

    2018-02-01

    Since the indication for receiving a cochlear implant (CI) has widened (single-sided deafness [SSD], electric acoustic stimulation [EAS], bilateral CI, CI for long-term deafness), more and more patients come into consideration for such a treatment. Hence, disputes increasingly arise between patients and their insurance companies concerning the question of whether surgery and follow-up treatment have to be paid for by statutory health insurance. This work provides an overview of judgments rendered by the German social courts. We investigated whether and in which cases it is advisable for a patient to go to court, and how long the proceedings may take. We looked for judgments in the two biggest commercial legal databases and in the database of the German social courts, using combinations of the search parameters "Cochlear," "Cochlea," "Implant," and "Implantat." Three verdicts were attained by directly contacting the court; another one was mentioned in an article. The reviewed judgements were issued between 2003 and 2017. A total of 12 judgments were found. The patients won in all but one of the main proceedings. The case that was lost concerned exceptional circumstances. One patient didn't get the desired interim measure, but won in the main proceedings. The proceedings took between 1 year and 8 months, and 9 years and 5 months. Despite the amount of time the patient has to invest, taking legal action is worthwhile. The proceedings at the social courts are generally exempt from charges. In most cases, the statutory health insurance is ordered to pay for a CI.

  20. Parental perspectives of children using cochlear implant.

    Science.gov (United States)

    Stefanini, Marcela Roselin; Morettin, Marina; Zabeu, Julia Speranza; Bevilacqua, Maria Cecília; Moret, Adriane Lima Mortari

    2014-01-01

    To evaluate the parents' perspective with regard to evolution of their child with cochlear implant (CI). This was a cross-sectional prospective study conducted at the Centro de Pesquisas Audiológicas of Hospital de Reabilitação de Anomalias Craniofaciais of Universidade de São Paulo. The selection of the sample was performed from the spontaneous demand, among the months from July to December 2011. The final sample comprised 50 parents or guardians of children using CI, with minimum 1 year and maximum of 3 years of device use. The translated and adapted to Brazilian Portuguese version of the questionnaire "Perspectives of parents of children with cochlear implants" was applied. This instrument consists of 74 questions and allows quantification of the parents' perspective on subscales that illustrate the situation of the child and family. Each question has five options scored from one to five responses. The Spearman test for comparison of results between the subscales was applied. The social relationships, self-sufficiency, and communication subscales showed the highest mean score, whereas the worst score was for child support subscale, reflecting the independence and autonomy of the patients. The correlation between the child subscales was realized, and the results showed themselves significant and positive for communication subscale of communication with all others subscales. The family subscales also had a positive correlation with the communication, education, and self-sufficiency. These results demonstrate that parents have good expectations regarding communication, independence, and social participation of children after CI surgery, and this questionnaire is a useful tool for use in clinical practice.

  1. Effect of unilateral and simultaneous bilateral cochlear implantation on tinnitus : A Prospective Study

    NARCIS (Netherlands)

    van Zon, Alice; Smulders, Yvette E.; Ramakers, Geerte G. J.; Stegeman, Inge; Smit, Adriana L.; Van Zanten, Gijsbert A.; Stokroos, Robert J.; Hendrice, Nadia; Free, Rolien H.; Maat, Bert; Frijns, Johan H. M.; Mylanus, Emmanuel A. M.; Huinck, Wendy J.; Topsakal, Vedat; Tange, Rinze A.; Grolman, Wilko

    Objectives/HypothesisTo determine the effect of cochlear implantation on tinnitus perception in patients with severe bilateral postlingual sensorineural hearing loss and to demonstrate possible differences between unilateral and bilateral cochlear implantation. Study DesignProspective study.

  2. Poul Erik Andersen's radiological work on Osteochondrodysplasias and interventional radiology

    DEFF Research Database (Denmark)

    Andersen, Poul Erik

    2011-01-01

    Hospital. His significant experience and extensive scientific work has led to many posts in the Danish Society of Interventional Radiology, the European Society of Radiology and the Cardiovascular and Interventional Radiological Society of Europe, where he is a fellow and has passed the European Board...... of Interventional Radiology - The European qualification in Interventional Radiology....

  3. Image Quality in Vascular Radiology

    International Nuclear Information System (INIS)

    Vanhavere, F.; Struelens, L.

    2005-01-01

    In vascular radiology, the radiologists use the radiological image to diagnose or treat a specific vascular structure. From literature, we know that related doses are high and that large dose variability exists between different hospitals. The application of the optimization principle is therefore necessary and is obliged by the new legislation. So far, very little fieldwork has been performed and no practical instructions are available to do the necessary work. It's indisputable that obtaining quantitative data is of great interest for optimization purposes. In order to gain insight into these doses and the possible measures for dose reduction, we performed a comparative study in 7 hospitals. Patient doses will be measured and calculated for specific procedures in vascular radiology and evaluated against their most influencing parameters. In view of optimization purposes, a protocol for dose audit will be set-up. From the results and conclusions in this study, experimentally based guidelines will be proposed, in order to improve clinical practice in vascular radiology

  4. Socioeconomic trends in radiology

    International Nuclear Information System (INIS)

    Barneveld Binkhuysen, F.H.

    1998-01-01

    For radiology the socioeconomic environment is a topic of increasing importance. In addition to the well-known important scientific developments in radiology such as interventional MRI, several other major trends can be recognized: (1) changes in the delivery of health care, in which all kinds of managed care are developing and will influence the practice of radiology, and (2) the process of computerization and digitization. The socioeconomic environment of radiology will be transformed by the developments in managed care, teleradiology and the integration of information systems. If radiologists want to manage future radiology departments they must have an understanding of the changes in the fields of economics and politics that are taking place and that will increasingly influence radiology. Some important and recognizable aspects of these changes will be described here. (orig.)

  5. The radiology report - Are we getting the message across?

    International Nuclear Information System (INIS)

    Wallis, A.; McCoubrie, P.

    2011-01-01

    The radiology report is the primary method of communication between radiologist and referrer. Despite this, radiologists receive very little formal training regarding the structure of the radiology report and also its importance as a medico-legal document. We present a review of radiology reporting, highlighting the importance of report structure and language with the purpose of helping radiologists improve the clarity, brevity, pertinence, and readability of reports. We encourage radiologists to avoid hedging and strive to improve communication with referring clinicians.

  6. Cochlear implantation in autistic children with profound sensorineural hearing loss.

    Science.gov (United States)

    Lachowska, Magdalena; Pastuszka, Agnieszka; Łukaszewicz-Moszyńska, Zuzanna; Mikołajewska, Lidia; Niemczyk, Kazimierz

    2016-11-19

    Cochlear implants have become the method of choice for the treatment of severe-to-profound hearing loss in both children and adults. Its benefits are well documented in the pediatric and adult population. Also deaf children with additional needs, including autism, have been covered by this treatment. The aim of this study was to assess the benefits from cochlear implantation in deafened children with autism as the only additional disability. This study analyzes data of six children. The follow-up time was at least 43 months. The following data were analyzed: medical history, reaction to music and sound, Ling's six sounds test, onomatopoeic word test, reaction to spoken child's name, response to requests, questionnaire given to parents, sound processor fitting sessions and data. After cochlear implantation each child presented other communication skills. In some children, the symptoms of speech understanding were observed. No increased hyperactivity associated with daily use cochlear implant was observed. The study showed that in autistic children the perception is very important for a child's sense of security and makes contact with parents easier. Our study showed that oral communication is not likely to be a realistic goal in children with cochlear implants and autism. The implantation results showed benefits that varied among those children. The traditional methods of evaluating the results of cochlear implantation in children with autism are usually insufficient to fully assess the functional benefits. These benefits should be assessed in a more comprehensive manner taking into account the limitations of communication resulting from the essence of autism. It is important that we share knowledge about these complex children with cochlear implants. Copyright © 2016 Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial. Published by Elsevier Editora Ltda. All rights reserved.

  7. Costs involved in using a cochlear implant in South Africa

    Directory of Open Access Journals (Sweden)

    Gillian Robyn Kerr

    2012-12-01

    Full Text Available Cochlear implantation is an expensive but effective lifelong intervention for individuals with a severe-to-profound hearing loss. The primary aim of this study was to survey the short- and long-term costs of cochlear implantation. Individuals (N=154 using cochlear implants obtained from the University of Stellenbosch-Tygerberg Hospital Cochlear Implant Unit in Cape Town, South Africa were surveyed using a questionnaire and patient record review. The questionnaire used a combination of closed and open-ended questions to gather both quantitative and qualitative information. Costs were categorised as short- and long-term costs. All costs were converted to constant rands (June 2010 using the Consumer Price Index to allow for comparison in real terms over time. In the first 10 years of implantation the average estimated costs incurred by adults totalled R379 626, and by children R455 225. The initial purchase of the implant system was the most substantial cost, followed by upgrading of the processor. Travel and accommodation costs peaked in the first 2 years. On average the participants spent R2 550 per year on batteries and spares. Rehabilitation for children cost an average of R7 200. Insurance costs averaged R4 040 per year, and processor repairs R3 000 each. In addition to the upfront expense of obtaining the cochlear implant system, individuals using a cochlear implant in South Africa should be prepared for the long-term costs of maintenance, accessing the unit, support services and additional costs associated with use. Knowledge of these costs is important to ensure that individuals are successful users of their cochlear implants in the long term.

  8. Radiological Emergency Response Data

    Data.gov (United States)

    U.S. Environmental Protection Agency — Quality Data Asset includes all current and historical emergency radiological response event and incident of national significance data and surveillance, monitoring,...

  9. Machine Learning and Radiology

    Science.gov (United States)

    Wang, Shijun; Summers, Ronald M.

    2012-01-01

    In this paper, we give a short introduction to machine learning and survey its applications in radiology. We focused on six categories of applications in radiology: medical image segmentation, registration, computer aided detection and diagnosis, brain function or activity analysis and neurological disease diagnosis from fMR images, content-based image retrieval systems for CT or MRI images, and text analysis of radiology reports using natural language processing (NLP) and natural language understanding (NLU). This survey shows that machine learning plays a key role in many radiology applications. Machine learning identifies complex patterns automatically and helps radiologists make intelligent decisions on radiology data such as conventional radiographs, CT, MRI, and PET images and radiology reports. In many applications, the performance of machine learning-based automatic detection and diagnosis systems has shown to be comparable to that of a well-trained and experienced radiologist. Technology development in machine learning and radiology will benefit from each other in the long run. Key contributions and common characteristics of machine learning techniques in radiology are discussed. We also discuss the problem of translating machine learning applications to the radiology clinical setting, including advantages and potential barriers. PMID:22465077

  10. Machine learning and radiology.

    Science.gov (United States)

    Wang, Shijun; Summers, Ronald M

    2012-07-01

    In this paper, we give a short introduction to machine learning and survey its applications in radiology. We focused on six categories of applications in radiology: medical image segmentation, registration, computer aided detection and diagnosis, brain function or activity analysis and neurological disease diagnosis from fMR images, content-based image retrieval systems for CT or MRI images, and text analysis of radiology reports using natural language processing (NLP) and natural language understanding (NLU). This survey shows that machine learning plays a key role in many radiology applications. Machine learning identifies complex patterns automatically and helps radiologists make intelligent decisions on radiology data such as conventional radiographs, CT, MRI, and PET images and radiology reports. In many applications, the performance of machine learning-based automatic detection and diagnosis systems has shown to be comparable to that of a well-trained and experienced radiologist. Technology development in machine learning and radiology will benefit from each other in the long run. Key contributions and common characteristics of machine learning techniques in radiology are discussed. We also discuss the problem of translating machine learning applications to the radiology clinical setting, including advantages and potential barriers. Copyright © 2012. Published by Elsevier B.V.

  11. Cochlearoids F-K: Phenolic meroterpenoids from the fungus Ganoderma cochlear and their renoprotective activity.

    Science.gov (United States)

    Wang, Xin-Long; Zhou, Feng-Jiao; Dou, Man; Yan, Yong-Ming; Wang, Shu-Mei; Di, Lei; Cheng, Yong-Xian

    2016-11-15

    Ganoderma mushrooms are of great nutritious and medicinal values. This study was designed to characterize compounds from the fruiting bodies of Ganoderma cochlear and investigate their protective effects against kidney disorders. Six novel meroterpenoids cochlearoids F-K (1-6) were isolated by utilizing phytochemical approaches. Their structures were identified on the basis of extensive spectroscopic data and calculation methods. Biological evaluation shows that compounds 1-4 and 6 exhibit potent inhibitory activity on fibronectin overproduction in TGF-β1-induced HKC-8 cells. Copyright © 2016 Elsevier Ltd. All rights reserved.

  12. A Stereo Music Preprocessing Scheme for Cochlear Implant Users.

    Science.gov (United States)

    Buyens, Wim; van Dijk, Bas; Wouters, Jan; Moonen, Marc

    2015-10-01

    Listening to music is still one of the more challenging aspects of using a cochlear implant (CI) for most users. Simple musical structures, a clear rhythm/beat, and lyrics that are easy to follow are among the top factors contributing to music appreciation for CI users. Modifying the audio mix of complex music potentially improves music enjoyment in CI users. A stereo music preprocessing scheme is described in which vocals, drums, and bass are emphasized based on the representation of the harmonic and the percussive components in the input spectrogram, combined with the spatial allocation of instruments in typical stereo recordings. The scheme is assessed with postlingually deafened CI subjects (N = 7) using pop/rock music excerpts with different complexity levels. The scheme is capable of modifying relative instrument level settings, with the aim of improving music appreciation in CI users, and allows individual preference adjustments. The assessment with CI subjects confirms the preference for more emphasis on vocals, drums, and bass as offered by the preprocessing scheme, especially for songs with higher complexity. The stereo music preprocessing scheme has the potential to improve music enjoyment in CI users by modifying the audio mix in widespread (stereo) music recordings. Since music enjoyment in CI users is generally poor, this scheme can assist the music listening experience of CI users as a training or rehabilitation tool.

  13. Image Registration of Cochlear µCT Data Using Heat Distribution Similarity

    DEFF Research Database (Denmark)

    Kjer, Hans Martin; Vera, Sergio; Fagertun, Jens

    2015-01-01

    Better understanding of the anatomical variability of the human cochlear is important for the design and function of Cochlear Implants. Good non-rigid alignment of high-resolution cochlear μCT data is a challenging task. In this paper we study the use of heat distribution similarity between sampl...

  14. New Criteria of Indication and Selection of Patients to Cochlear Implant

    Directory of Open Access Journals (Sweden)

    André L. L. Sampaio

    2011-01-01

    Full Text Available Numerous changes continue to occur in cochlear implant candidacy. In general, these have been accompanied by concomitant and satisfactory changes in surgical techniques. Together, this has advanced the utility and safety of cochlear implantation. Most devices are now approved for use in patients with severe to profound unilateral hearing loss rather then the prior requirement of a bilateral profound loss. Furthermore, studies have begun utilizing short electrode arrays for shallow insertion in patients with considerable low-frequency residual hearing. This technique will allow the recipient to continue to use acoustically amplified hearing for the low frequencies simultaneously with a cochlear implant for the high frequencies. The advances in design of, and indications for, cochlear implants have been matched by improvements in surgical techniques and decrease in complications. The resulting improvements in safety and efficacy have further encouraged the use of these devices. This paper will review the new concepts in the candidacy of cochlear implant. Medline data base was used to search articles dealing with the following topics: cochlear implant in younger children, cochlear implant and hearing preservation, cochlear implant for unilateral deafness and tinnitus, genetic hearing loss and cochlear implant, bilateral cochlear implant, neuropathy and cochlear implant and neural plasticity, and the selection of patients for cochlear implant.

  15. Trophic structure and biomass distribution of macrobenthos on ...

    African Journals Online (AJOL)

    The trophic structure and biomass of macrobenthos on both wave-sheltered, rocky intertidal shores and semi-exposed ones at seven localities in the Tsitsikamma Marine Protected Area were compared. In the Cochlear zone and entire intertidal (Cochlear- and Balanoid zones combined) biomass values of invertebrates and ...

  16. Factors associated with hearing loss in a normal-hearing guinea pig model of Hybrid cochlear implants.

    Science.gov (United States)

    Tanaka, Chiemi; Nguyen-Huynh, Anh; Loera, Katherine; Stark, Gemaine; Reiss, Lina

    2014-10-01

    The Hybrid cochlear implant (CI), also known as Electro-Acoustic Stimulation (EAS), is a new type of CI that preserves residual acoustic hearing and enables combined cochlear implant and hearing aid use in the same ear. However, 30-55% of patients experience acoustic hearing loss within days to months after activation, suggesting that both surgical trauma and electrical stimulation may cause hearing loss. The goals of this study were to: 1) determine the contributions of both implantation surgery and EAS to hearing loss in a normal-hearing guinea pig model; 2) determine which cochlear structural changes are associated with hearing loss after surgery and EAS. Two groups of animals were implanted (n = 6 per group), with one group receiving chronic acoustic and electric stimulation for 10 weeks, and the other group receiving no direct acoustic or electric stimulation during this time frame. A third group (n = 6) was not implanted, but received chronic acoustic stimulation. Auditory brainstem response thresholds were followed over time at 1, 2, 6, and 16 kHz. At the end of the study, the following cochlear measures were quantified: hair cells, spiral ganglion neuron density, fibrous tissue density, and stria vascularis blood vessel density; the presence or absence of ossification around the electrode entry was also noted. After surgery, implanted animals experienced a range of 0-55 dB of threshold shifts in the vicinity of the electrode at 6 and 16 kHz. The degree of hearing loss was significantly correlated with reduced stria vascularis vessel density and with the presence of ossification, but not with hair cell counts, spiral ganglion neuron density, or fibrosis area. After 10 weeks of stimulation, 67% of implanted, stimulated animals had more than 10 dB of additional threshold shift at 1 kHz, compared to 17% of implanted, non-stimulated animals and 0% of non-implanted animals. This 1-kHz hearing loss was not associated with changes in any of the cochlear measures

  17. [Reporting initiatives. An update on treatment in radiology].

    Science.gov (United States)

    Hempel, J-M; Pinto dos Santos, D; Kloeckner, R; Dueber, C; Mildenberger, P

    2014-07-01

    The written radiological report is the most important means of communication between the radiologist and the referring medical doctor. There is no universal definition of a radiological report concerning its structure and content. The majority of clinicians and radiologists prefer structured reporting rather than free text reports of findings. Structured reporting does not increase the quality of a radiological report but has many advantages in research, teaching and quality management. Using standard RadLex terms facilitates translation and ontological assignment of a report. The Reporting Initiative of the Radiological Society of North America (RSNA) offers free and freely available extensively validated best practices radiology report templates in the new management of radiology report templates (MRRT) format according to the guidelines of the Integrating the Healthcare Enterprise (IHE).

  18. Transcanal labyrinthectomy for intractable vertigo after unilateral cochlear implantation.

    Science.gov (United States)

    Heidenreich, Katherine D; Basura, Gregory J; Zwolan, Teresa A; El-Kashlan, Hussam K; Telian, Steven A

    2011-10-01

    Document the use of transcanal labyrinthectomy to treat disabling attacks of vertigo after unilateral cochlear implantation. A 46-year-old woman with severe-profound bilateral sensorineural hearing loss secondary to enlarged vestibular aqueducts underwent cochlear implantation for her right ear with a Nucleus Freedom device. The surgery was uneventful, and postoperative imaging confirmed that the electrode was positioned properly. She developed episodic vertigo 10 to 14 days after the implant surgery, which failed to improve with aggressive vestibular rehabilitation therapy. Plugging of the round window for possible perilymphatic fistula did not relieve her symptoms. Right transcanal labyrinthectomy supplemented by filling the vestibule with gentamicin-soaked Gelfoam and then a customized vestibular rehabilitation program. Comparison of vestibular symptoms and cochlear implant performance before and after transcanal labyrinthectomy. The patient had immediate relief of symptoms, and the function of the cochlear implant was not adversely affected. Transcanal labyrinthectomy may be an effective method to ablate the vestibular end organ after unilateral cochlear implantation. It can offer relief of disabling vertigo without adversely affecting the performance of the implant.

  19. Hyperbaric oxygen upregulates cochlear constitutive nitric oxide synthase

    Directory of Open Access Journals (Sweden)

    Kao Ming-Ching

    2011-02-01

    Full Text Available Abstract Background Hyperbaric oxygen therapy (HBOT is a known adjuvant for treating ischemia-related inner ear diseases. Controversies still exist in the role of HBOT in cochlear diseases. Few studies to date have investigated the cellular changes that occur in inner ears after HBOT. Nitric oxide, which is synthesized by nitric oxide synthase (NOS, is an important signaling molecule in cochlear physiology and pathology. Here we investigated the effects of hyperbaric oxygen on eardrum morphology, cochlear function and expression of NOS isoforms in cochlear substructures after repetitive HBOT in guinea pigs. Results Minor changes in the eardrum were observed after repetitive HBOT, which did not result in a significant hearing threshold shift by tone burst auditory brainstem responses. A differential effect of HBOT on the expression of NOS isoforms was identified. Upregulation of constitutive NOS (nNOS and eNOS was found in the substructures of the cochlea after HBOT, but inducible NOS was not found in normal or HBOT animals, as shown by immunohistochemistry. There was no obvious DNA fragmentation present in this HBOT animal model. Conclusions The present evidence indicates that the customary HBOT protocol may increase constitutive NOS expression but such upregulation did not cause cell death in the treated cochlea. The cochlear morphology and auditory function are consequently not changed through the protocol.

  20. Verbal Working Memory in Children With Cochlear Implants

    Science.gov (United States)

    Caldwell-Tarr, Amanda; Low, Keri E.; Lowenstein, Joanna H.

    2017-01-01

    Purpose Verbal working memory in children with cochlear implants and children with normal hearing was examined. Participants Ninety-three fourth graders (47 with normal hearing, 46 with cochlear implants) participated, all of whom were in a longitudinal study and had working memory assessed 2 years earlier. Method A dual-component model of working memory was adopted, and a serial recall task measured storage and processing. Potential predictor variables were phonological awareness, vocabulary knowledge, nonverbal IQ, and several treatment variables. Potential dependent functions were literacy, expressive language, and speech-in-noise recognition. Results Children with cochlear implants showed deficits in storage and processing, similar in size to those at second grade. Predictors of verbal working memory differed across groups: Phonological awareness explained the most variance in children with normal hearing; vocabulary explained the most variance in children with cochlear implants. Treatment variables explained little of the variance. Where potentially dependent functions were concerned, verbal working memory accounted for little variance once the variance explained by other predictors was removed. Conclusions The verbal working memory deficits of children with cochlear implants arise due to signal degradation, which limits their abilities to acquire phonological awareness. That hinders their abilities to store items using a phonological code. PMID:29075747

  1. Prevalence of inner ear anomalies among cochlear implant candidates.

    Science.gov (United States)

    Aldhafeeri, Ahmad M; Alsanosi, Abdulrahman A

    2016-10-01

    To determine the prevalence of inner ear anomalies and the frequency of different anomaly types among cochlear implant recipients. This study included a retrospective chart review of all patients who received cochlear implants between January 2009 and January 2013 in King Abdulaziz University Hospital cochlear implant program in Riyadh, Saudi Arabia. All subjects underwent thin-cut CT of the temporal bone and MRI. The collected data included age, gender, and CT and MRI findings regarding temporal bone anomalies. Patients with any identified congenital inner ear anomalies were included in the study.  In total, 316 patients' cases were reviewed. Inner ear malformations were identified in 24 patients, which represented a prevalence of 7.5%. Among these 24 patients, 8 (33.3%) presented with a large vestibular aqueduct (LVA), 8 (33.3%) semicircular canal (SCC) dysplasia, 7 (29.1%) classical Mondini deformity, and one (4.1%) cochlear hypoplasia. The prevalence of inner ear anomalies among cochlear implant recipients was 7.5%. This result is consistent with findings worldwide. The most common anomalies were LVA and SCC hypoplasia; by contrast, in other regions, the most common anomaly is either the Mondini deformity, or LVA.

  2. Fourteen-years experience with cochlear implantation in Ramathibodi Hospital.

    Science.gov (United States)

    Kasemsuwan, Lalida; Cheewaruangroj, Wichit; Tungkeeratichai, Jumroon; Bhongmakapat, Thongchai; Thawin, Cheamchit; Lertsukprasert, Krisna; Tiravanitchakul, Rattinan; Dara, Rada; Laothamatas, Jiraporn

    2010-12-01

    To review the cochlear implant program in Ramathibodi Hospital and share experience of cochlear implantation emphasized on clinical and surgical outcomes. Retrospective review of 143 ears (140 patients) operated with cochlear implant between 1995 and 2009. The demographic data including etiology of deafness and findings from temporal bone CTscans were reviewed. The authors' experience with cochlear implant surgery in terms of patient selection, patient advisory clinic, necessary equipment, pre- and postoperative evaluations, surgical techniques and complications were discussed. Most congenital origin was unknown etiology and congenital rubella was the most common known cause. From the CT scans of congenital deafness, vestibular aqueduct dilatation was the most common and found in 29.31% while Mondini malformation was shown to be 16.37%. The authors' surgical technique of using the pocket method and designed bony ridge at cortical mastoid rim had helped stabilizing the implant and electrode fancoil. During the last two years, no complication or revision surgery was detected. Cochlear implant surgery in both children and adults can result in good surgical outcome and fewer complications under experienced surgeons and a good team.

  3. Cochlear injury and adaptive plasticity of the auditory cortex

    Directory of Open Access Journals (Sweden)

    ANNA R. eFETONI

    2015-02-01

    Full Text Available Growing evidence suggests that cochlear stressors as noise exposure and aging can induce homeostatic/maladaptive changes in the central auditory system from the brainstem to the cortex. Studies centered on such changes have revealed several mechanisms that operate in the context of sensory disruption after insult (noise trauma, drug- or age-related injury. The oxidative stress is central to current theories of induced sensory neural hearing loss and aging, and interventions to attenuate the hearing loss are based on antioxidant agent. The present review addresses the recent literature on the alterations in hair cells and spiral ganglion neurons due to noise-induced oxidative stress in the cochlea, as well on the impact of cochlear damage on the auditory cortex neurons. The emerging image emphasizes that noise-induced deafferentation and upward spread of cochlear damage is associated with the altered dendritic architecture of auditory pyramidal neurons. The cortical modifications may be reversed by treatment with antioxidants counteracting the cochlear redox imbalance. These findings open new therapeutic approaches to treat the functional consequences of the cortical reorganization following cochlear damage.

  4. Cochlear Implants and Psychiatric Assessments: a Norrie Disease Case Report.

    Science.gov (United States)

    Jacques, Denis; Dubois, Thomas; Zdanowicz, Nicolas; Gilain, Chantal; Garin, Pierre

    2017-09-01

    It is important to perform psychiatric assessments of adult patients who are candidates for cochlear implants both to screen them for psychiatric disorders and to assess their understanding and compliance with the procedure. Deafness is a factor of difficulty for conducting in-depth psychiatric interviews, but concomitant blindness may make it impossible. After a description of Norrie disease, a rare disease in which blindness and deafness may occur together, we propose a case report of a patient suffering from the disease and who consulted in view of a cochlear implant. Early information on cochlear implants appears to be necessary before total deafness occurs in patients suffering from Norrie disease. An inventory of digital communication tools that can be used by the patient is also highly valuable. Research should be supported for a more systematic use of psychiatric assessments prior to cochlear implants. In the special case of Norrie disease, we recommend early screening for mental retardation and related psychotic disorders and, depending on the patient's level of understanding, preventive information on the benefits and limits of cochlear implants before total deafness occurs.

  5. Influence of cochlear implantation on peripheral vestibular receptor function.

    Science.gov (United States)

    Krause, Eike; Louza, Julia P R; Wechtenbruch, Juliane; Gürkov, Robert

    2010-06-01

    The objectives of this study were 1) to assess the influence of a cochlear implantation on peripheral vestibular receptor function in the inner ear in the implant and in the nonimplant side, and 2) to analyze a possible correlation with resulting vertigo symptoms. Prospective clinical study. Cochlear implant center at tertiary referral hospital. A total of 32 patients, aged 15 to 83 years, undergoing cochlear implantation were assessed pre- and postoperatively for caloric horizontal semicircular canal response and vestibular-evoked myogenic potentials of the sacculus, and postoperatively for subjective vertigo symptoms. Patients with vertigo were compared with patients without symptoms with regard to the findings of the vestibular function tests. Cochlear implantation represents a significant risk factor for horizontal semicircular canal impairment (P 0.05). Cochlear implantation is a relevant risk factor for damage of peripheral vestibular receptor function. Therefore, preservation not only of residual hearing function but also of vestibular function should be aimed for, by using minimally invasive surgical techniques. Copyright 2010 American Academy of Otolaryngology-Head and Neck Surgery Foundation. Published by Mosby, Inc. All rights reserved.

  6. Disrupted bone remodeling leads to cochlear overgrowth and hearing loss in a mouse model of fibrous dysplasia.

    Directory of Open Access Journals (Sweden)

    Omar Akil

    Full Text Available Normal hearing requires exquisite cooperation between bony and sensorineural structures within the cochlea. For example, the inner ear secretes proteins such as osteoprotegrin (OPG that can prevent cochlear bone remodeling. Accordingly, diseases that affect bone regulation can also result in hearing loss. Patients with fibrous dysplasia develop trabecular bone overgrowth resulting in hearing loss if the lesions affect the temporal bones. Unfortunately, the mechanisms responsible for this hearing loss, which could be sensorineural and/or conductive, remain unclear. In this study, we used a unique transgenic mouse model of increased Gs G-protein coupled receptor (GPCR signaling induced by expression of an engineered receptor, Rs1, in osteoblastic cells. These ColI(2.3+/Rs1+ mice showed dramatic bone lesions that histologically and radiologically resembled fibrous dysplasia. We found that ColI(2.3+/Rs1+ mice showed progressive and severe conductive hearing loss. Ossicular chain impingement increased with the size and number of dysplastic lesions. While sensorineural structures were unaffected, ColI(2.3+/Rs1+ cochleae had abnormally high osteoclast activity, together with elevated tartrate resistant acid phosphatase (TRAP activity and receptor activator of nuclear factor kappa-B ligand (Rankl mRNA expression. ColI(2.3+/Rs1+ cochleae also showed decreased expression of Sclerostin (Sost, an antagonist of the Wnt signaling pathway that normally increases bone formation. The osteocyte canalicular networks of ColI(2.3+/Rs1+ cochleae were disrupted and showed abnormal osteocyte morphology. The osteocytes in the ColI(2.3+/Rs1+ cochleae showed increased expression of matrix metalloproteinase 13 (MMP-13 and TRAP, both of which can support osteocyte-mediated peri-lacunar remodeling. Thus, while the ossicular chain impingement is sufficient to account for the progressive hearing loss in fibrous dysplasia, the deregulation of bone remodeling extends to the

  7. [Instruction in dental radiology

    NARCIS (Netherlands)

    Sanden, W.J.M. van der; Kreulen, C.M.; Berkhout, W.E.

    2016-01-01

    The diagnostic use of oral radiology is an essential part of daily dental practice. Due to the potentially harmful nature of ionising radiation, the clinical use of oral radiology in the Netherlands is framed by clinical practice guidelines and regulatory requirements. Undergraduate students receive

  8. Medical Ethics in Radiology

    International Nuclear Information System (INIS)

    Kim, Kyung Won; Park, Jae Hyung; Yoon, Soon Ho

    2010-01-01

    According to the recent developments in radiological techniques, the role of radiology in the clinical management of patients is ever increasing and in turn, so is the importance of radiology in patient management. Thus far, there have been few open discussions about medical ethics related to radiology in Korea. Hence, concern about medical ethics as an essential field of radiology should be part of an improved resident training program and patient management. The categories of medical ethics related with radiology are ethics in the radiological management of patient, the relationship of radiologists with other medical professionals or companies, the hazard level of radiation for patients and radiologists, quality assurance of image products and modalities, research ethics, and other ethics issues related to teleradiology and fusion imaging. In order to achieve the goal of respectful progress in radiology as well as minimizing any adverse reaction from other medical professions or society, we should establish a strong basis of medical ethics through the continuous concern and self education

  9. Physics of Radiology

    CERN Document Server

    Johns, Harold Elford

    1983-01-01

    Authority, comprehensivity and a consummate manner of presentation have been hallmarks of The Physics of Radiology since it first saw publication some three decades past. This Fourth Edition adheres to that tradition but again updates the context. It thoroughly integrates ideas recently advanced and practices lately effected. Students and professionals alike will continue to view it, in essence, as the bible of radiological physics.

  10. Gout. Radiological aspects

    International Nuclear Information System (INIS)

    Restrepo Suarez, Jose Felix; Pena Cortes, Mario; Rondon Herrera, Federico; Iglesias Gamarra, Antonio; Calvo Paramo, Enrique

    2000-01-01

    In this paper we reviewed the clinical and radiological aspects of gout, showing the most frequent radiological findings that can guide to the correct diagnosis of the disease. The cases that we presented here have been analyzed for many years in our rheumatology service, Universidad Nacional de Colombia, Hospital San Juan de Dios, Bogota

  11. [Vestibulo-cochlear disturbances in the course of vaso-neural conflict of vestibule-cochlear nerve--diagnostic and therapeutic problems].

    Science.gov (United States)

    Orendorz-Fraczkowska, Krystyna; Jaworska, Marzena; Gawron, Wojciech; Badowski, Roman; Nadolska, Beata

    2007-01-01

    Symptoms encompassing sensorineural hearing loss, tinnitus and vertigo occur in many diseases of various origin. The diagnostics in such cases is especially difficult and often requires interdisciplinary cooperation. Despite of that many cases remain unexplained. The two cases with above mentioned symptoms (52 year-old woman and 46 year-old man) with differentiated clinical course were presented. The woman for one year experienced left sided, extreme tinnitus with paroxysmal vertigo and dizziness. The man with sudden monolateral hearing loss and tinnitus that disappeared after corticosteroid therapy, complained about recurrence of fluctuating hearing loss and tinnitus accompanied by chronic instability. The diagnostics of hearing and balance organs was performed (pure tone audiometry, impedance audiometry, DPOAE, ABR, ENG) complemented with computed tomography and Nuclear Resonance. Female patient presented bilateral mild sensorineural hearing loss, more intensive on the left side, male patient right sided sensorineural hearing loss in the frequencies from 250 to 1500 Hz. The elongation of some peak values in ABR test (with bilaterally proper otoacoustic emissions) as well as partial canal paresis on the hearing loss side suggested primary diagnosis of neoplasmatic process. It was an indication to perform radiological diagnostics. The radiologic findings revealed the contact of vestibulo-cochlear nerve with the loop of cerebellar inferior anterior artery within the internal acoustic canal. The course of the disease and diagnostic tests do not provide characteristic data that let diagnose neuro-vascular conflict. One has to be aware of such possibility in patients with intensive vertigo and dizziness that do not improve after treatment when other causes do not justify the symptoms.

  12. Assessment of radiological protection systems among diagnostic radiology facilities in North East India.

    Science.gov (United States)

    Singh, Thokchom Dewan; Jayaraman, T; Arunkumar Sharma, B

    2017-03-01

    This study aims to assess the adequacy level of radiological protection systems available in the diagnostic radiology facilities located in three capital cities of North East (NE) India. It further attempts to understand, using a multi-disciplinary approach, how the safety codes/standards in diagnostic radiology framed by the Atomic Energy Regulatory Board (AERB) and the International Atomic Energy Agency (IAEA) to achieve adequate radiological protection in facilities, have been perceived, conceptualized, and applied accordingly in these facilities. About 30 diagnostic radiology facilities were randomly selected from three capitals of states in NE India; namely Imphal (Manipur), Shillong (Meghalaya) and Guwahati (Assam). A semi-structured questionnaire developed based on a multi-disciplinary approach was used for this study. It was observed that radiological practices undertaken in these facilities were not exactly in line with safety codes/standards in diagnostic radiology of the AERB and the IAEA. About 50% of the facilities had registered/licensed x-ray equipment with the AERB. More than 80% of the workers did not use radiation protective devices, although these devices were available in the facilities. About 85% of facilities had no institutional risk management system. About 70% of the facilities did not carry out periodic quality assurance testing of their x-ray equipment or surveys of radiation leakage around the x-ray room, and did not display radiation safety indicators in the x-ray rooms. Workers in these facilities exhibited low risk perception about the risks associated with these practices. The majority of diagnostic radiology facilities in NE India did not comply with the radiological safety codes/standards framed by the AERB and IAEA. The study found inadequate levels of radiological protection systems in the majority of facilities. This study suggests a need to establish firm measures that comply with the radiological safety codes/standards of the

  13. Image processing in radiology

    International Nuclear Information System (INIS)

    Dammann, F.

    2002-01-01

    Medical imaging processing and analysis methods have significantly improved during recent years and are now being increasingly used in clinical applications. Preprocessing algorithms are used to influence image contrast and noise. Three-dimensional visualization techniques including volume rendering and virtual endoscopy are increasingly available to evaluate sectional imaging data sets. Registration techniques have been developed to merge different examination modalities. Structures of interest can be extracted from the image data sets by various segmentation methods. Segmented structures are used for automated quantification analysis as well as for three-dimensional therapy planning, simulation and intervention guidance, including medical modelling, virtual reality environments, surgical robots and navigation systems. These newly developed methods require specialized skills for the production and postprocessing of radiological imaging data as well as new definitions of the roles of the traditional specialities. The aim of this article is to give an overview of the state-of-the-art of medical imaging processing methods, practical implications for the ragiologist's daily work and future aspects. (orig.) [de

  14. Effects of chronic furosemide on central neural hyperactivity and cochlear thresholds after cochlear trauma in guinea pig

    Directory of Open Access Journals (Sweden)

    Wilhelmina eMulders

    2014-08-01

    Full Text Available Increased neuronal spontaneous firing rates have been observed throughout the central auditory system after trauma to the cochlea and this hyperactivity is believed to be associated with the phantom perception of tinnitus. Previously we have shown in an animal model of hearing loss, that an acute injection with furosemide can significantly decrease hyperactivity after cochlear trauma and eliminate behavioural evidence of tinnitus of early onset. However, furosemide also has the potential to affect cochlear thresholds. In this paper we measured the effects of a chronic (daily injections for 7 days furosemide treatment on the spontaneous firing rate of inferior colliculus neurons and on cochlear thresholds in order to establish whether a beneficial effect on hyperactivity can be obtained without causing additional hearing loss. Guinea pigs were exposed to a 10 kHz, 124dB, 2 hour acoustic trauma, and after 5 days of recovery, were given daily i.p. injections of 80mg/kg furosemide or an equivalent amount of saline. The activity of single IC neurons was recorded 24 hours following the last injection. The furosemide treatment had no effect on cochlear thresholds compared to saline injections but did result in significant reductions in spontaneous firing rates recorded in inferior colliculus. These results that suggest a long term beneficial effect of furosemide on hyperactivity after cochlear trauma may be achievable without detrimental effects on hearing, which is important when considering therapeutic potential.

  15. High resolution micro-CT scanning as an innovative tool for evaluation of the surgical positioning of cochlear implant electrodes.

    Science.gov (United States)

    Postnov, A; Zarowski, A; De Clerck, N; Vanpoucke, F; Offeciers, F E; Van Dyck, D; Peeters, S

    2006-05-01

    X-ray microtomography (micro-CT) is a new technique allowing for visualization of the internal structure of opaque specimens with a quasi-histological quality. Among multiple potential applications, the use of this technique in otology is very promising. Micro-CT appears to be ideally suited for in vitro visualization of the inner ear tissues as well as for evaluation of the electrode damage and/or surgical insertion trauma during implantation of the cochlear implant electrodes. This technique can greatly aid in design and development of new cochlear implant electrodes and is applicable for temporal bone studies. The main advantage of micro-CT is the practically artefact-free preparation of the samples and the possibility of evaluation of the interesting parameters along the whole insertion depth of the electrode. This paper presents the results of the first application of micro-CT for visualization of the inner ear structures in human temporal bones and for evaluation of the surgical positioning of the cochlear implant electrodes relative to the intracochlear soft tissues.

  16. Role of Radiology in Forensic Dentistry

    Directory of Open Access Journals (Sweden)

    T Chandrasekhar

    2011-01-01

    Full Text Available Forensic radiology is a specialized area of medical imaging utilizing radiological techniques to assist physicians and pathologists in matter pertaining to the law. Postmortem dental radiographs are the most consistent part of the antemortem records that can be transmitted during the forensic examination procedures. Pathologists regularly use radiographic images during the course of autopsy to assist them in identification of foreign bodies or determination of death. Forensic radiology can be used in suspicious death or murder, in analysis of adverse medical events, solving legal matters, to detect child abuse, drug trafficking, body identification and disease identification. Using the possibilities of radiology, special characteristics of the internal structures of the dentomaxillofacial region can be revealed. We can also detect endodontic treatments, healing extraction sockets, implants or even tooth colored restoration. Therefore, we can give answers to problems dealing with identification procedures, mass disaster and dental age estimation.

  17. Radiological protection report 2016

    International Nuclear Information System (INIS)

    2017-06-01

    on the basis of international recommendations. ENSI uses inspections and comparative measurements to ensure that the necessary calibrated radiological protection measurement equipment is available and that it is used for its intended purpose in order to determine correct values. For this purpose, it operates a test centre accredited to ISO 17025. The network operated by ENSI for automatically monitoring the dose rate in the vicinity of nuclear power plants measures dose rates in the vicinity of nuclear power stations all year round and 24 hours a day. The 10-minute, hourly and daily mean rates measured can be viewed on ENSI's web site in real time. This monitoring network serves to secure evidence for the authorities and in dealings with the public. No local increases in dose rates that could be attributed to discharges from nuclear power plants were detected in the reporting year. Sporadic, locally high measurements are due to fluctuations in natural background radiation, e.g. after rainfall. The programme JRODOS (Java-based Realtime Online DecisiOn Support system) has been used since the beginning of 2016 to model atmospheric spread and calculate the dose, should an event occur. JRODOS allows the direct use of 3D weather forecast data from the COSMO-1 model routinely used by MeteoSwiss with a grid size of 1 km. The COSMO-1 model supplies forecasts stretching up to 24 hours into the future with high spatial and temporal resolution. In order to reflect the small scale structure of the Swiss countryside and that of southern Germany, JRODOS uses the very high resolution elevation model from the Swiss Federal Office of Topography. This means that together with the aerial radiometric equipment, there are invaluable, precise instruments available at all times for making current assessments (diagnoses) as well as forecasts of the radiological situation. In the reporting year, all thresholds contained in the Federal Ordinance on radiation protection were met. There

  18. The scala vestibuli for cochlear implantation. An anatomic study.

    Science.gov (United States)

    Gulya, A J; Steenerson, R L

    1996-02-01

    Traditionally, cochlear implantation has used the scala tympani (ST) for electrode insertion. When faced with ST ossification, the surgeon may elect to drill out the cochlea to accomplish partial electrode insertion. Theoretically, another option in this situation is to insert the electrode into the scala vestibuli (SV). To determine whether or not the dimensions of the SV are sufficient to accommodate an electrode array so as to assess the feasibility of SV cochlear implantation. The study of 20 normal human temporal bones, comparing the maximum diameter and surface area of the ST with those of the combined SV and scala media. The dimensions of the SV and scala media were comparable to those of the ST and appeared sufficient to accommodate a cochlear implant electrode array. It appears that the combination of SV and scala media is a viable alternative route for electrode insertion, at least on the basis of anatomic dimensions, in those cases in which the ST is obliterated.

  19. Cochlear changes in presbycusis with tinnitus.

    Science.gov (United States)

    Terao, Kyoichi; Cureoglu, Sebahattin; Schachern, Patricia A; Morita, Norimasa; Nomiya, Shigenobu; Deroee, Armin F; Doi, Katsumi; Mori, Kazunori; Murata, Kiyotaka; Paparella, Michael M

    2011-01-01

    The pathophysiology of tinnitus is obscure and its treatment is therefore elusive. Significant progress in this field can only be achieved by determining the mechanisms of tinnitus generation, and thus, histopathologic findings of the cochlea in presbycusis with tinnitus become crucial. We revealed the histopathologic findings of the cochlea in subjects with presbycusis and tinnitus. The subjects were divided into 2 groups, presbycusis with tinnitus (tinnitus) group and presbycusis without tinnitus (control) group, with each group comprising 8 temporal bones from 8 subjects. We quantitatively analyzed the number of spiral ganglion cells, loss of cochlear inner and outer hair cells, and areas of the stria vascularis and spiral ligament. There was a significantly greater loss of outer hair cells in the tinnitus group compared with the control group in the basal and upper middle turns. The stria vascularis was more atrophic in the tinnitus group compared with the control group in the basal turn. Tinnitus is more common in patients with presbycusis who have more severe degeneration of outer hair cells and stria vascularis. Copyright © 2011 Elsevier Inc. All rights reserved.

  20. Cochlear implant users' spectral ripple resolution.

    Science.gov (United States)

    Jeon, Eun Kyung; Turner, Christopher W; Karsten, Sue A; Henry, Belinda A; Gantz, Bruce J

    2015-10-01

    This study revisits the issue of the spectral ripple resolution abilities of cochlear implant (CI) users. The spectral ripple resolution of recently implanted CI recipients (implanted during the last 10 years) were compared to those of CI recipients implanted 15 to 20 years ago, as well as those of normal-hearing and hearing-impaired listeners from previously published data from Henry, Turner, and Behrens [J. Acoust. Soc. Am. 118, 1111-1121 (2005)]. More recently, implanted CI recipients showed significantly better spectral ripple resolution. There is no significant difference in spectral ripple resolution for these recently implanted subjects compared to hearing-impaired (acoustic) listeners. The more recently implanted CI users had significantly better pre-operative speech perception than previously reported CI users. These better pre-operative speech perception scores in CI users from the current study may be related to better performance on the spectral ripple discrimination task; however, other possible factors such as improvements in internal and external devices cannot be excluded.

  1. Cochlear nucleus neuron analysis in individuals with presbycusis.

    Science.gov (United States)

    Hinojosa, Raul; Nelson, Erik G

    2011-12-01

    The aim of this study was to analyze the cochlear nucleus neuron population in individuals with normal hearing and presbycusis. Retrospective study of archival human temporal bone and brain stem tissues. Using strict inclusion criteria, the temporal bones and cochlear nuclei from six normal hearing individuals and four individuals with presbycusis were selected for analysis. The spiral ganglion cell population, the cochlear nucleus neuron population, and the cell body size of the neurons were quantified in these cases. A relationship was not observed between age and the spiral ganglion cell population in the normal hearing group. Presbycusis subjects exhibited a reduced spiral ganglion cell population. The mean cochlear nucleus neuron population was observed to be significantly higher in the presbycusis group (mean ± standard deviation: 114,170 ± 10,570) compared to the normal hearing group (91,470 ± 9,510) (P = .019). This difference was predominantly the result of greater multipolar and granule cell neuron populations. Only the fusiform neuron type exhibited a significantly different mean cell body cross-sectional area between the normal hearing group (242 ± 27) and the presbycusis group (300 ± 37) (P = .033). This investigation is the first time, to our knowledge, that the populations of the eight neuron types in the cochlear nucleus have been quantified in both normal hearing individuals and individuals with presbycusis. The data support the concept that presbycusis is not an effect of aging alone but instead may be a condition that predisposes one to hearing loss with advancing age and is characterized by a congenitally elevated cochlear nucleus neuron population. Copyright © 2011 The American Laryngological, Rhinological, and Otological Society, Inc.

  2. Tinnitus after Simultaneous and Sequential Bilateral Cochlear Implantation.

    Science.gov (United States)

    Ramakers, Geerte G J; Kraaijenga, Véronique J C; Smulders, Yvette E; van Zon, Alice; Stegeman, Inge; Stokroos, Robert J; Free, Rolien H; Frijns, Johan H M; Huinck, Wendy J; Van Zanten, Gijsbert A; Grolman, Wilko

    2017-01-01

    There is an ongoing global discussion on whether or not bilateral cochlear implantation should be standard care for bilateral deafness. Contrary to unilateral cochlear implantation, however, little is known about the effect of bilateral cochlear implantation on tinnitus. To investigate tinnitus outcomes 1 year after bilateral cochlear implantation. Secondarily, to compare tinnitus outcomes between simultaneous and sequential bilateral cochlear implantation and to investigate long-term follow-up (3 years). This study is a secondary analysis as part of a multicenter randomized controlled trial. Thirty-eight postlingually deafened adults were included in the original trial, in which the presence of tinnitus was not an inclusion criterion. All participants received cochlear implants (CIs) because of profound hearing loss. Nineteen participants received bilateral CIs simultaneously and 19 participants received bilateral CIs sequentially with an inter-implant interval of 2 years. The prevalence and severity of tinnitus before and after simultaneous and sequential bilateral cochlear implantation were measured preoperatively and each year after implantation with the Tinnitus Handicap Inventory (THI) and Tinnitus Questionnaire (TQ). The prevalence of preoperative tinnitus was 42% (16/38). One year after bilateral implantation, there was a median difference of -8 (inter-quartile range (IQR): -28 to 4) in THI score and -9 (IQR: -17 to -9) in TQ score in the participants with preoperative tinnitus. Induction of tinnitus occurred in five participants, all in the simultaneous group, in the year after bilateral implantation. Although the preoperative and also the postoperative median THI and TQ scores were higher in the simultaneous group, the median difference scores were equal in both groups. In the simultaneous group, tinnitus scores fluctuated in the 3 years after implantation. In the sequential group, four patients had an additional benefit of the second CI: a total

  3. Tinnitus after Simultaneous and Sequential Bilateral Cochlear Implantation

    Directory of Open Access Journals (Sweden)

    Geerte G. J. Ramakers

    2017-11-01

    Full Text Available ImportanceThere is an ongoing global discussion on whether or not bilateral cochlear implantation should be standard care for bilateral deafness. Contrary to unilateral cochlear implantation, however, little is known about the effect of bilateral cochlear implantation on tinnitus.ObjectiveTo investigate tinnitus outcomes 1 year after bilateral cochlear implantation. Secondarily, to compare tinnitus outcomes between simultaneous and sequential bilateral cochlear implantation and to investigate long-term follow-up (3 years.Study designThis study is a secondary analysis as part of a multicenter randomized controlled trial.MethodsThirty-eight postlingually deafened adults were included in the original trial, in which the presence of tinnitus was not an inclusion criterion. All participants received cochlear implants (CIs because of profound hearing loss. Nineteen participants received bilateral CIs simultaneously and 19 participants received bilateral CIs sequentially with an inter-implant interval of 2 years. The prevalence and severity of tinnitus before and after simultaneous and sequential bilateral cochlear implantation were measured preoperatively and each year after implantation with the Tinnitus Handicap Inventory (THI and Tinnitus Questionnaire (TQ.ResultsThe prevalence of preoperative tinnitus was 42% (16/38. One year after bilateral implantation, there was a median difference of −8 (inter-quartile range (IQR: −28 to 4 in THI score and −9 (IQR: −17 to −9 in TQ score in the participants with preoperative tinnitus. Induction of tinnitus occurred in five participants, all in the simultaneous group, in the year after bilateral implantation. Although the preoperative and also the postoperative median THI and TQ scores were higher in the simultaneous group, the median difference scores were equal in both groups. In the simultaneous group, tinnitus scores fluctuated in the 3 years after implantation. In the sequential group

  4. Staphylococcus lugdunensis: novel organism causing cochlear implant infection

    Directory of Open Access Journals (Sweden)

    Samina Bhumbra

    2014-06-01

    Full Text Available A majority of cochlear implant infections are caused by Staphylococcus aureus or Pseudomonas aeruginosa. Reported here is a pediatric patient with a cochlear implant infection caused by methicillin-resistant Staphylococcus lugdunensis, a coagulase-negative Staphylococcus that has only recently been determined to be clinically relevant (1988. Unlike other coagulase-negative Staphylococcus, it is more aggressive, carrying a greater potential for tissue destruction. In pediatrics, the organism is uncommon, poorly described, and generally pan-susceptible. Described herein is the presentation and management of this unusual organism in a pediatric setting.

  5. Dislocation of cochlear implant magnet as a complication following MRI.

    Science.gov (United States)

    Murtojärvi, Sarita; Salonen, Jaakko

    According to current best knowledge, an MRI scan can be performed for patients with cochlear implants. The warnings and recommendations of the implant manufacturers must be followed strictly to prevent complications, such as overheating, migration or demagnetization of the magnet in the implant. We report on a case of cochlear implant magnet dislocation as a complication for an MRI scan. The patient had a tight bandage around the head to hold the magnet in place as recommended by the manufacturer, but apparently the bandage was not in the correct place.

  6. Cochlear implantation outcomes in children with common cavity deformity; a retrospective study.

    Science.gov (United States)

    Zhang, Li; Qiu, Jianxin; Qin, Feifei; Zhong, Mei; Shah, Gyanendra

    2017-09-01

    A common cavity deformity (CCD) is a deformed inner ear in which the cochlea and vestibule are confluent forming a common rudimentary cystic cavity that results in profound hearing loss. There are few studies paying attention to common cavity. Our group is engrossed in observing the improvement of auditory and verbal abilities in children who have received cochlear implantation (CI), and comparing these targets between children with common cavity and normal inner ear structure. A retrospective study was conducted in 12 patients with profound hearing loss that were divided into a common cavity group and a control group, six in each group matched in sex, age and time of implantation, based on inner ear structure. Categories of Auditory Performance (CAP) and speech intelligibility rating (SIR) scores and aided hearing thresholds were collected and compared between the two groups. All patients wore CI for more than 1 year at the Cochlear Center of Anhui Medical University from 2011 to 2015. Postoperative CAP and SIR scores were higher than before operation in both groups (p good as in those without CCD, CI provides benefits in auditory perception and communication skills in these children.

  7. Marketing a Radiology Practice.

    Science.gov (United States)

    Levin, David C; Rao, Vijay M; Flanders, Adam E; Sundaram, Baskaran; Colarossi, Margaret

    2016-10-01

    In addition to being a profession, the practice of radiology is a business, and marketing is an important part of that business. There are many facets to marketing a radiology practice. The authors present a number of ideas on how to go about doing this. Some marketing methods can be directed to both patients and referring physicians. Others should be directed just to patients, while still others should be directed just to referring physicians. Aside from marketing, many of them provide value to both target audiences. Copyright © 2016 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  8. Guidelines for radiological interventions

    International Nuclear Information System (INIS)

    Kauffmann, G.W.

    1998-01-01

    The German Radiological Society, in cooperation with other German professional bodies, set up draft Guidelines for Radiological Interventions and submitted them to the professional community for discussion. The Guidelines are meant to assess the potential of radiological interventions as treatment alternatives to surgery or aggressive therapy such as chemotherapy. In fact, technical practicability on its own is insufficient to warrant intervention. The Guidelines are systematically compiled notions and recommendations whose aim it is to provide support to physicians and patients in choosing suitable medical care provisions (prevention, diagnosis, therapy, aftertreatment) in specific circumstances. A complete Czech translation of the Guidelines is given. (P.A.)

  9. Interventional Radiology in Paediatrics.

    Science.gov (United States)

    Chippington, Samantha J; Goodwin, Susie J

    2015-01-01

    As in adult practice, there is a growing role for paediatric interventional radiology expertise in the management of paediatric pathologies. This review is targeted for clinicians who may refer their patients to paediatric interventional radiology services, or who are responsible for patients who are undergoing paediatric interventional radiology procedures. The article includes a brief overview of the indications for intervention, techniques involved and the commonest complications. Although some of the procedures described are most commonly performed in a tertiary paediatric centre, many are performed in most Children's hospitals.

  10. Intraoperative cochlear nerve mapping with the mobile cochlear nerve compound action potential tracer in vestibular schwannoma surgery.

    Science.gov (United States)

    Watanabe, Nobuyuki; Ishii, Takuya; Fujitsu, Kazuhiko; Kaku, Shogo; Ichikawa, Teruo; Miyahara, Kosuke; Okada, Tomu; Tanino, Shin; Uriu, Yasuhiro; Murayama, Yuichi

    2018-05-18

    OBJECTIVE The authors describe the usefulness and limitations of the cochlear nerve compound action potential (CNAP) mobile tracer (MCT) that they developed to aid in cochlear nerve mapping during vestibular schwannoma surgery (VSS) for hearing preservation. METHODS This MCT device requires no more than 2 seconds for stable placement on the nerve to obtain the CNAP and thus is able to trace the cochlear nerve instantaneously. Simultaneous bipolar and monopolar recording is possible. The authors present the outcomes of 18 consecutive patients who underwent preoperative useful hearing (defined as class I or II of the Gardner-Robertson classification system) and underwent hearing-preservation VSS with the use of the MCT. Mapping was considered successful when it was possible to detect and trace the cochlear nerve. RESULTS Mapping of the cochlear nerve was successful in 13 of 18 patients (72.2%), and useful hearing was preserved in 11 patients (61.1%). Among 8 patients with large tumors (Koos grade 3 or 4), the rate of successful mapping was 62.5% (5 patients). The rate of hearing preservation in patients with large tumors was 50% (4 patients). CONCLUSIONS In addition to microsurgical presumption of the arrangement of each nerve, frequent probing on and around an unidentified nerve and comparison of each waveform are advisable with the use of both more sensitive monopolar and more location-specific bipolar MCT. MCT proved to be useful in cochlear nerve mapping and may consequently be helpful in hearing preservation. The authors discuss some limitations and problems with this device.

  11. Advanced radiology information system.

    Science.gov (United States)

    Kolovou, L; Vatousi, M; Lymperopoulos, D; Koukias, M

    2005-01-01

    The innovative features of an advanced Radiology Information System (RIS) are presented in this paper. The interoperability of RIS with the other Intra-hospital Information Systems that interacts with, dealing with the compatibility and open architecture issues, are accomplished by two novel mechanisms [1]. The first one is the particular message handling system that is applied for the exchange of information, according to the Health Level Seven (HL7) protocol's specifications and serves the transfer of medical and administrative data among the RIS applications and data store unit. The same mechanism allows the secure and HL7-compatible interactions with the Hospital Information System (HIS) too. The second one implements the translation of information between the formats that HL7 and Digital Imaging and Communication in Medicine (DICOM) protocols specify, providing the communication between RIS and Picture and Archive Communication System (PACS). The whole structure ensures the automation of the every-day procedures that the ;medical protocol' specifies and provides its services through a friendly and easy to manage graphical user interface.

  12. Epilepsy and radiological investigations

    International Nuclear Information System (INIS)

    Tomberg, T.

    2005-01-01

    Epilepsy is a heterogenous group of disorders with multiple causes. Clinical management of epilepsy patients requires knowledge of seizure syndromes, causes, and imaging features. The aim of radiological investigations is to recognize the underlying cause of epilepsy. The main indications for neuroimaging studies are partial and secondarily generalized seizures, patients with neurological signs and intractable seizures, and patients with focal signs on EEG. Partial seizures of any type are more likely to be associated with a focus that may be identified on neuroimaging. MRI is the method of choice for evaluating structural abnormalities of the brain. High resolution MRI and dedicated imaging technique are needed for detection of subtle pathological changes as cortical dysplasias and temporal medial sclerosis. Other lesions that may be detected include neoplasms, vascular malformations, destructive lesions following brain injury, stroke, infection, etc. CT continues to be the technique for the investigation of patients with seizures under certain conditions. New techniques such as functional MRI, MR spectroscopy, SPECT, receptor PET and magnetic source imaging are becoming clinical tools for improving diagnosis [et

  13. Bilateral cochlear implants in infants: a new approach--Nucleus Hybrid S12 project.

    Science.gov (United States)

    Gantz, Bruce J; Dunn, Camille C; Walker, Elizabeth A; Kenworthy, Maura; Van Voorst, Tanya; Tomblin, Bruce; Turner, Chris

    2010-10-01

    The purpose of this feasibility study was to evaluate whether the use of a shorter-length cochlear implant (10 mm) on one ear and a standard electrode (24 mm) on the contralateral ear is a viable bilateral option for children with profound bilateral sensorineural hearing loss. A secondary purpose of this study was to determine whether the ear with the shorter-length electrode performs similarly to the standard-length electrode. Our goal was to provide an option of electrical stimulation that theoretically might preserve the structures of the scala media and organ of Corti. The study is being conducted as a repeated-measure, single-subject experiment. University of Iowa-Department of Otolaryngology. Eight pediatric patients with profound bilateral sensorineural hearing loss between the ages of 12 and 24 months. Nucleus Hybrid S12 10-mm electrode and a Nucleus Freedom implant in the contralateral ear. The Infant-Toddler Meaningful Auditory Integration Scale (IT-MAIS) parent questionnaire, Early Speech Perception, Glendonald Auditory Screening Procedure word test, and Children's Vowel tests will be used to evaluate speech perception and the Minnesota Child Development Inventory and Preschool Language Scales 3 test will be used to evaluate language growth. Preliminary results for 8 children have been collected before and after the operation using the IT-MAIS. All 3 children showed incremental improvements in their IT-MAIS scores overtime. Early Speech Perception, Glendonald Auditory Screening Procedure word test, and Children's Vowel word perception results indicated no difference between the individual ears for the 2 children tested. Performance compared with age-matched children implanted with standard bilateral cochlear implants showed similar results to the children implanted with Nucleus Hybrid S12 10-mm electrode and a Nucleus Freedom implant in contralateral ears. The use of a shorter-length cochlear implant on one ear and a standard-length electrode on the

  14. Bilateral Cochlear Implants in Infants: A New Approach—Nucleus Hybrid S12 Project

    Science.gov (United States)

    Gantz, Bruce J.; Dunn, Camille C.; Walker, Elizabeth A.; Kenworthy, Maura; Van Voorst, Tanya; Tomblin, Bruce; Turner, Chris

    2010-01-01

    Objective The purpose of this feasibility study was to evaluate whether the use of a shorter-length cochlear implant (10 mm) on one ear and a standard electrode (24 mm) on the contralateral ear is a viable bilateral option for children with profound bilateral sensorineural hearing loss. A secondary purpose of this study was to determine whether the ear with the shorter-length electrode performs similarly to the standard-length electrode. Our goal was to provide an option of electrical stimulation that theoretically might preserve the structures of the scala media and organ of Corti. Study Design The study is being conducted as a repeated-measure, single-subject experiment. Setting University of Iowa—Department of Otolaryngology. Patients Eight pediatric patients with profound bilateral sensorineural hearing loss between the ages of 12 and 24 months. Interventions Nucleus Hybrid S12 10-mm electrode and a Nucleus Freedom implant in the contralateral ear. Main Outcome Measures The Infant-Toddler Meaningful Auditory Integration Scale (IT-MAIS) parent questionnaire, Early Speech Perception, Glendonald Auditory Screening Procedure word test, and Children’s Vowel tests will be used to evaluate speech perception and the Minnesota Child Development Inventory and Preschool Language Scales 3 test will be used to evaluate language growth. Results Preliminary results for 8 children have been collected before and after the operation using the IT-MAIS. All 3 children showed incremental improvements in their IT-MAIS scores overtime. Early Speech Perception, Glendonald Auditory Screening Procedure word test, and Children’s Vowel word perception results indicated no difference between the individual ears for the 2 children tested. Performance compared with age-matched children implanted with standard bilateral cochlear implants showed similar results to the children implanted with Nucleus Hybrid S12 10-mm electrode and a Nucleus Freedom implant in contralateral ears

  15. Pediatric radiology for medical-technical radiology assistants/radiologists

    International Nuclear Information System (INIS)

    Oppelt, Birgit

    2010-01-01

    The book on pediatric radiology includes the following chapter: differences between adults and children; psycho-social aspects concerning the patient child in radiology; relevant radiation doses in radiology; help for self-help: simple phantoms for image quality estimation in pediatric radiology; general information; immobilization of the patient; pediatric features for radiological settings; traumatology; contrast agents; biomedical radiography; computerized tomography; NMR imaging; diagnostic ultrasonography; handling of stress practical recommendations; medical displays.

  16. Radiological assessment and optimization

    International Nuclear Information System (INIS)

    Zeevaert, T.; Sohier, A.

    1998-01-01

    The objectives of SCK-CEN's research in the field of radiological assessment and optimization are (1) to implement ALARA principles in activities with radiological consequences; (2) to develop methodologies for radiological optimization in decision-aiding; (3) to improve methods to assess in real time the radiological hazards in the environment in case of an accident; (4) to develop methods and programmes to assist decision-makers during a nuclear emergency; (5) to support the policy of radioactive waste management authorities in the field of radiation protection; (6) to investigate computer codes in the area of multi criteria analysis; (7) to organise courses on off-site emergency response to nuclear accidents. Main achievements in these areas for 1997 are summarised

  17. Laenderyggens degeneration og radiologi

    DEFF Research Database (Denmark)

    Jacobsen, Steffen; Gosvig, Kasper Kjaerulf; Sonne-Holm, Stig

    2006-01-01

    Low back pain (LBP) is one of the most common conditions, and at the same time one of the most complex nosological entities. The lifetime prevalence is approximately 80%, and radiological features of lumbar degeneration are almost universal in adults. The individual risk factors for LBP and signi......Low back pain (LBP) is one of the most common conditions, and at the same time one of the most complex nosological entities. The lifetime prevalence is approximately 80%, and radiological features of lumbar degeneration are almost universal in adults. The individual risk factors for LBP...... and significant relationships between radiological findings and subjective symptoms have both been notoriously difficult to identify. The lack of consensus on clinical criteria and radiological definitions has hampered the undertaking of properly executed epidemiological studies. The natural history of LBP...

  18. Diagnostic radiology: I

    International Nuclear Information System (INIS)

    Anon.

    1993-01-01

    This chapter describes the historic development of diagnostic equipment for radiology. The problems associated with fluoroscope design are detailed and the current uses of updated technology, particularly digitization, are considered. Numerous historical photographs are included. 13 refs

  19. Ergonomics in radiology

    Energy Technology Data Exchange (ETDEWEB)

    Goyal, N. [Department of Radiology, University Hospital of Wales, Cardiff (United Kingdom)], E-mail: nimitgoyal@doctors.org.uk; Jain, N.; Rachapalli, V. [Department of Radiology, University Hospital of Wales, Cardiff (United Kingdom)

    2009-02-15

    The use of computers is increasing in every field of medicine, especially radiology. Filmless radiology departments, speech recognition software, electronic request forms and teleradiology are some of the recent developments that have substantially increased the amount of time a radiologist spends in front of a computer monitor. Computers are also needed for searching literature on the internet, communicating via e-mails, and preparing for lectures and presentations. It is well known that regular computer users can suffer musculoskeletal injuries due to repetitive stress. The role of ergonomics in radiology is to ensure that working conditions are optimized in order to avoid injury and fatigue. Adequate workplace ergonomics can go a long way in increasing productivity, efficiency, and job satisfaction. We review the current literature pertaining to the role of ergonomics in modern-day radiology especially with the development of picture archiving and communication systems (PACS) workstations.

  20. SA Journal of Radiology

    African Journals Online (AJOL)

    SA Journal of Radiology. Journal Home · ABOUT THIS JOURNAL · Advanced Search · Current Issue · Archives · Journal Home > Vol 19, No 2 (2015) >. Log in or Register to get access to full text downloads.

  1. SA Journal of Radiology

    African Journals Online (AJOL)

    SA Journal of Radiology. Journal Home · ABOUT THIS JOURNAL · Advanced Search · Current Issue · Archives · Journal Home > Vol 21, No 1 (2017) >. Log in or Register to get access to full text downloads.

  2. Ergonomics in radiology

    International Nuclear Information System (INIS)

    Goyal, N.; Jain, N.; Rachapalli, V.

    2009-01-01

    The use of computers is increasing in every field of medicine, especially radiology. Filmless radiology departments, speech recognition software, electronic request forms and teleradiology are some of the recent developments that have substantially increased the amount of time a radiologist spends in front of a computer monitor. Computers are also needed for searching literature on the internet, communicating via e-mails, and preparing for lectures and presentations. It is well known that regular computer users can suffer musculoskeletal injuries due to repetitive stress. The role of ergonomics in radiology is to ensure that working conditions are optimized in order to avoid injury and fatigue. Adequate workplace ergonomics can go a long way in increasing productivity, efficiency, and job satisfaction. We review the current literature pertaining to the role of ergonomics in modern-day radiology especially with the development of picture archiving and communication systems (PACS) workstations

  3. Society of Interventional Radiology

    Science.gov (United States)

    ... Picture yourself in L.A. Register now SIR Essentials Purchase/register Search SIR's entire catalog for educational ... Quality Improvement Clinical practice MACRA Matters Health Policy, Economics, Coding Toolkits Society of Interventional Radiology 3975 Fair ...

  4. Radiology Architecture Project Primer.

    Science.gov (United States)

    Sze, Raymond W; Hogan, Laurie; Teshima, Satoshi; Davidson, Scott

    2017-12-19

    The rapid pace of technologic advancement and increasing expectations for patient- and family-friendly environments make it common for radiology leaders to be involved in imaging remodel and construction projects. Most radiologists and business directors lack formal training in architectural and construction processes but are expected to play significant and often leading roles in all phases of an imaging construction project. Avoidable mistakes can result in significant increased costs and scheduling delays; knowledgeable participation and communication can result in a final product that enhances staff workflow and morale and improves patient care and experience. This article presents practical guidelines for preparing for and leading a new imaging architectural and construction project. We share principles derived from the radiology and nonradiology literature and our own experience over the past decade completely remodeling a large pediatric radiology department and building a full-service outpatient imaging center. Copyright © 2017 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  5. Radiology and the law

    International Nuclear Information System (INIS)

    Bundy, A.L.

    1988-01-01

    This book contains 12 chapters. Some of the chapter titles are: The Law of Medical Malpractice: An Overview; The Radiologist as Defendant; The Radiologist as an Expert Witness; The Missed Diagnosis; Legalities of the Radiograph; and Angiography and Interventional Radiology

  6. Worker radiological protection: occupational medical aspects

    International Nuclear Information System (INIS)

    Cardenas Herrera, Juan; Fernandez Gomez, Isis Maria

    2008-01-01

    Radiation exposures experienced by workers are widely explained. The first evidences of biological effects, the implications for human health and the radiological protection have been covered. The conceptual structure that covers the radiological protection and adequate protection without limiting benefits, the scientific basis of radiology, the benefits and risks of the radiological protection are specified. The effective per capita doses are exposed in medical uses both for Latin America and for other regions in the average radiology, dental radiology, nuclear medicine and radiotherapy. The manners of occupational exposures in the medicine are presented. Industrial uses have also its average effective dose in the industrial irradiation, industrial radiography and radioisotopes production. Within the natural radiation the natural sources can significantly contribute to occupational exposure and have their average effective dose. Occupational medical surveillance to be taken into industrial sites is detailed. In addition, the plan of international action for the solution of dilemmas of occupational exposures is mentioned and the different dilemmas of radioactive exposure are showed. The external irradiation, the acute diseases by radiations, the cutaneous syndrome of the chronic radiation, the radioactive contamination, the internal radioactive contamination, the combined lesion and accidental exposures are also treated [es

  7. Radiological clerkships as a critical curriculum component in radiology education

    International Nuclear Information System (INIS)

    Kourdioukova, Elena V.; Verstraete, Koenraad L.; Valcke, Martin

    2011-01-01

    Objective: The aim of this research was to explore the perceived value of clinical clerkships in the radiology curriculum as well as the impact of radiology clerkship on students' beliefs about the profession of radiology as a whole and as a career. Methods: This study is a sequel to a previous survey in which student perceptions about radiology curriculum components were investigated. The present study focuses on a further analysis of a subsection in this study, based on 14 statements about radiology clerkship and two statements about radiology as a career. Results: Perceived usefulness of the aspects of radiology clerkship as 'radiology examination', 'skills development' and 'diagnosis focus' were awarded the highest scores. The predict value of the subscale 'radiology examination' on the level of performance was very high (adjusted R 2 = 0.19, p < .001). Conclusion: Students expressed highly favorable evaluation of clerkship as a learning environment to learn to order and to interpret imaging studies as well as an unique possibility to attend various radiological examinations and to access to specific radiology software systems, as well as to get a better view on radiology and to improve image interpretation skills. This positive attitude towards clerkship is closely tied to students' beliefs about the profession of radiology as a whole. These aspects of dedicated radiology clerkship are crucial for effective and high-quality education as well as for the choice of radiology as a career.

  8. Radiologic science for technologists

    International Nuclear Information System (INIS)

    Bushong, S.C.

    1988-01-01

    This book provides in-depth coverage of physics, biology and protection for the radiologic technology student. It presents a significant portion of all of the science required of radiologic technology students under one cover. Chapter content reflects a readable and practical organization with outlines listed on the first page of each chapter and sample problems at the end. New to this edition are: new and expanded sections on radiation techniques, digital imaging, and magnetic resonance imaging and ultrasound

  9. Hygiene in radiology

    International Nuclear Information System (INIS)

    Kapp-Schwoerer, A.; Daschner, F.

    1987-01-01

    A survey is given of the hygienic management in radiological departments with special regard to the handling of injections and infusions. It includes prevention of bacterial as well as viral infections. In radiological departments disinfection of X-ray tables is necessary only in exceptional cases. A special proposal for disinfection is added. A safe method of sterilisation of flexible catheders is included, which proved to prevent bacterial infection. (orig.) [de

  10. Radiological protection act, 1991

    International Nuclear Information System (INIS)

    1991-01-01

    This Act provides for the establishment of the Radiological Protection Institute of Ireland and dissolves An Bord Fuinnimh Nuicleigh (the Board), transferring its assets and liabilities to the Institute. It sets out a range of radiation protection measures to be taken by various Ministers in the event of a radiological emergency and gives effect at national level to the Assistance Convention, the Early Notification Convention and the Physical Protection Convention. The Institute is the competent Irish authority for the three Conventions. (NEA) [fr

  11. Textbook of radiology

    International Nuclear Information System (INIS)

    Putman, C.E.; Ravin, C.E.

    1987-01-01

    This book is presented in two volumes, standard textbook of imaging, conclusive and totally up-to-date. This provides information organized by major topics covering the state-of-the-art for all imaging procedures. The volume 1 presents radiologic physics and technology by discussing roentgenography, ultrasound, CT, nuclear medicine, MRI, and positron emission tomography. The volume 2 studies pulmonary radiology, imaging of the skeletal and central nervous systems, uroradiology, abdominal and cardiac imaging, and imaging of the pelvis

  12. Laenderyggens degeneration og radiologi

    DEFF Research Database (Denmark)

    Jacobsen, Steffen; Gosvig, Kasper Kjaerulf; Sonne-Holm, Stig

    2006-01-01

    and significant relationships between radiological findings and subjective symptoms have both been notoriously difficult to identify. The lack of consensus on clinical criteria and radiological definitions has hampered the undertaking of properly executed epidemiological studies. The natural history of LBP...... is cyclic: exacerbations relieved by asymptomatic periods. New imaging modalities, including the combination of MR imaging and multiplanar 3-D CT scans, have broadened our awareness of possible pain-generating degenerative processes of the lumbar spine other than disc degeneration....

  13. Multisensory Integration in Cochlear Implant Recipients.

    Science.gov (United States)

    Stevenson, Ryan A; Sheffield, Sterling W; Butera, Iliza M; Gifford, René H; Wallace, Mark T

    Speech perception is inherently a multisensory process involving integration of auditory and visual cues. Multisensory integration in cochlear implant (CI) recipients is a unique circumstance in that the integration occurs after auditory deprivation and the provision of hearing via the CI. Despite the clear importance of multisensory cues for perception, in general, and for speech intelligibility, specifically, the topic of multisensory perceptual benefits in CI users has only recently begun to emerge as an area of inquiry. We review the research that has been conducted on multisensory integration in CI users to date and suggest a number of areas needing further research. The overall pattern of results indicates that many CI recipients show at least some perceptual gain that can be attributable to multisensory integration. The extent of this gain, however, varies based on a number of factors, including age of implantation and specific task being assessed (e.g., stimulus detection, phoneme perception, word recognition). Although both children and adults with CIs obtain audiovisual benefits for phoneme, word, and sentence stimuli, neither group shows demonstrable gain for suprasegmental feature perception. Additionally, only early-implanted children and the highest performing adults obtain audiovisual integration benefits similar to individuals with normal hearing. Increasing age of implantation in children is associated with poorer gains resultant from audiovisual integration, suggesting a sensitive period in development for the brain networks that subserve these integrative functions, as well as length of auditory experience. This finding highlights the need for early detection of and intervention for hearing loss, not only in terms of auditory perception, but also in terms of the behavioral and perceptual benefits of audiovisual processing. Importantly, patterns of auditory, visual, and audiovisual responses suggest that underlying integrative processes may be

  14. Cochlear neuropathy and the coding of supra-threshold sound.

    Science.gov (United States)

    Bharadwaj, Hari M; Verhulst, Sarah; Shaheen, Luke; Liberman, M Charles; Shinn-Cunningham, Barbara G

    2014-01-01

    Many listeners with hearing thresholds within the clinically normal range nonetheless complain of difficulty hearing in everyday settings and understanding speech in noise. Converging evidence from human and animal studies points to one potential source of such difficulties: differences in the fidelity with which supra-threshold sound is encoded in the early portions of the auditory pathway. Measures of auditory subcortical steady-state responses (SSSRs) in humans and animals support the idea that the temporal precision of the early auditory representation can be poor even when hearing thresholds are normal. In humans with normal hearing thresholds (NHTs), paradigms that require listeners to make use of the detailed spectro-temporal structure of supra-threshold sound, such as selective attention and discrimination of frequency modulation (FM), reveal individual differences that correlate with subcortical temporal coding precision. Animal studies show that noise exposure and aging can cause a loss of a large percentage of auditory nerve fibers (ANFs) without any significant change in measured audiograms. Here, we argue that cochlear neuropathy may reduce encoding precision of supra-threshold sound, and that this manifests both behaviorally and in SSSRs in humans. Furthermore, recent studies suggest that noise-induced neuropathy may be selective for higher-threshold, lower-spontaneous-rate nerve fibers. Based on our hypothesis, we suggest some approaches that may yield particularly sensitive, objective measures of supra-threshold coding deficits that arise due to neuropathy. Finally, we comment on the potential clinical significance of these ideas and identify areas for future investigation.

  15. Cochlear Neuropathy and the Coding of Supra-threshold Sound

    Directory of Open Access Journals (Sweden)

    Hari M Bharadwaj

    2014-02-01

    Full Text Available Many listeners with hearing thresholds within the clinically normal range nonetheless complain of difficulty hearing in everyday settings and understanding speech in noise. Converging evidence from human and animal studies points to one potential source of such difficulties: differences in the fidelity with which supra-threshold sound is encoded in the early portions of the auditory pathway. Measures of auditory subcortical steady-state responses in humans and animals support the idea that the temporal precision of the early auditory representation can be poor even when hearing thresholds are normal. In humans with normal hearing thresholds, behavioral ability in paradigms that require listeners to make use of the detailed spectro-temporal structure of supra-threshold sound, such as selective attention and discrimination of frequency modulation, correlate with subcortical temporal coding precision. Animal studies show that noise exposure and aging can cause a loss of a large percentage of auditory nerve fibers without any significant change in measured audiograms. Here, we argue that cochlear neuropathy may reduce encoding precision of supra-threshold sound, and that this manifests both behaviorally and in subcortical steady-state responses in humans. Furthermore, recent studies suggest that noise-induced neuropathy may be selective for higher-threshold, lower-spontaneous-rate nerve fibers. Based on our hypothesis, we suggest some approaches that may yield particularly sensitive, objective measures of supra-threshold coding deficits that arise due to neuropathy. Finally, we comment on the potential clinical significance of these ideas and identify areas for future investigation.

  16. The Phonemic Awareness Skills of Cochlear Implant Children and Children with Normal Hearing in Primary School

    Directory of Open Access Journals (Sweden)

    Aliakbar Dashtelei

    2015-12-01

    Full Text Available Objectives: Phonemic awareness skills have a significant impact on children speech and language. The purpose of this study was investigating the phonemic awareness skills of children with cochlear implant and normal hearing peers in primary school. Methods: phonemic awareness subscales of phonological awareness test were administered to 30 children with cochlear implantation at the first to sixth grades of primary school and 30 children with normal hearing who were matched in age with cochlear implant group. All of children were between 6 to 11 years old. Children with cochlear implant had at least 1 to 2 years of implant experience and they were over 5 years when they receive implantation. Children with cochlear implant were selected from Special education centers in Tehran and children with normal hearing were recruited from primary schools in Tehran. The phonemic awareness skills were assessed in both groups. Results: The results showed that the Mean scores of phonemic awareness skills in cochlear implant children were significantly lower than children with normal hearing (P<.0001. Discussion: children with cochlear implant, despite Cochlear implantation prosthesis, had lower performance in phonemic awareness when compared with normal hearing children. Therefore, due to importance of phonemic awareness skills in learning of literacy skills, and defects of these skills in children with cochlear implant, these skills should be assessed carefully in children with cochlear implant and rehabilitative interventions should be considered.

  17. Strategies for Working with Children with Cochlear Implants

    Science.gov (United States)

    Schraer-Joiner, Lyn; Prause-Weber, Manuela

    2009-01-01

    According to the National Institute on Deafness and Other Communication Disorders, 23,000 individuals in the United States, including 10,000 children, have a cochlear implant. This biomedical electronic device has been a breakthrough in the auditory rehabilitation of individuals diagnosed with severe or profound sensorineural hearing losses who…

  18. Cochlear implantation and change in quality of life

    DEFF Research Database (Denmark)

    Faber, Christian; Grøntved, Ågot Møller

    2000-01-01

    The aim of this study was to assess the benefits of cochlear implantation (CI) in adults and to evaluate the average implant usage per day. Ten profoundly deaf adults were implanted during the period April 1994 to September 1997. The patients answered questionnaires 1 year or more after receiving...

  19. The influence of cochlear implant electrode position on performance

    NARCIS (Netherlands)

    Marel, K.S. van der; Briaire, J.J.; Verbist, B.M.; Muurling, T.J.; Frijns, J.H.M.

    2015-01-01

    To study the relation between variables related to cochlear implant electrode position and speech perception performance scores in a large patient population.The study sample consisted of 203 patients implanted with a CII or HiRes90K implant with a HiFocus 1 or 1J electrode of Advanced Bionics.

  20. Pneumococcal meningitis post-cochlear implantation: preventative measures.

    Science.gov (United States)

    Wei, Benjamin P C; Shepherd, Robert K; Robins-Browne, Roy M; Clark, Graeme M; O'Leary, Stephen J

    2010-11-01

    Both clinical data and laboratory studies demonstrated the risk of pneumococcal meningitis post-cochlear implantation. This review examines strategies to prevent post-implant meningitis. Medline/PubMed database; English articles after 1980. Search terms: cochlear implants, pneumococcus meningitis, streptococcus pneumonia, immunization, prevention. Narrative review. All articles relating to post-implant meningitis without any restriction in study designs were assessed and information extracted. The presence of inner ear trauma as a result of surgical technique or cochlear implant electrode array design was associated with a higher risk of post-implant meningitis. Laboratory data demonstrated the effectiveness of pneumococcal vaccination in preventing meningitis induced via the hematogenous route of infection. Fibrous sealing around the electrode array at the cochleostomy site, and the use of antibiotic-coated electrode array reduced the risk of meningitis induced via an otogenic route. The recent scientific data support the U.S. Food and Drug Administration recommendation of pneumococcal vaccination for the prevention of meningitis in implant recipients. Nontraumatic cochlear implant design, surgical technique, and an adequate fibrous seal around the cochleostomy site further reduce the risk of meningitis. Copyright © 2010 American Academy of Otolaryngology–Head and Neck Surgery Foundation. Published by Mosby, Inc. All rights reserved.

  1. Identification and Multiplicity of Double Vowels in Cochlear Implant Users

    Science.gov (United States)

    Kwon, Bomjun J.; Perry, Trevor T.

    2014-01-01

    Purpose: The present study examined cochlear implant (CI) users' perception of vowels presented concurrently (i.e., "double vowels") to further our understanding of auditory grouping in electric hearing. Method: Identification of double vowels and single vowels was measured with 10 CI subjects. Fundamental frequencies (F0s) of…

  2. Automatic Model Generation Framework for Computational Simulation of Cochlear Implantation.

    Science.gov (United States)

    Mangado, Nerea; Ceresa, Mario; Duchateau, Nicolas; Kjer, Hans Martin; Vera, Sergio; Dejea Velardo, Hector; Mistrik, Pavel; Paulsen, Rasmus R; Fagertun, Jens; Noailly, Jérôme; Piella, Gemma; González Ballester, Miguel Ángel

    2016-08-01

    Recent developments in computational modeling of cochlear implantation are promising to study in silico the performance of the implant before surgery. However, creating a complete computational model of the patient's anatomy while including an external device geometry remains challenging. To address such a challenge, we propose an automatic framework for the generation of patient-specific meshes for finite element modeling of the implanted cochlea. First, a statistical shape model is constructed from high-resolution anatomical μCT images. Then, by fitting the statistical model to a patient's CT image, an accurate model of the patient-specific cochlea anatomy is obtained. An algorithm based on the parallel transport frame is employed to perform the virtual insertion of the cochlear implant. Our automatic framework also incorporates the surrounding bone and nerve fibers and assigns constitutive parameters to all components of the finite element model. This model can then be used to study in silico the effects of the electrical stimulation of the cochlear implant. Results are shown on a total of 25 models of patients. In all cases, a final mesh suitable for finite element simulations was obtained, in an average time of 94 s. The framework has proven to be fast and robust, and is promising for a detailed prognosis of the cochlear implantation surgery.

  3. Speech Recognition and Cognitive Skills in Bimodal Cochlear Implant Users

    Science.gov (United States)

    Hua, Håkan; Johansson, Björn; Magnusson, Lennart; Lyxell, Björn; Ellis, Rachel J.

    2017-01-01

    Purpose: To examine the relation between speech recognition and cognitive skills in bimodal cochlear implant (CI) and hearing aid users. Method: Seventeen bimodal CI users (28-74 years) were recruited to the study. Speech recognition tests were carried out in quiet and in noise. The cognitive tests employed included the Reading Span Test and the…

  4. Libyan cochlear implant programme: achievements, difficulties, and future goals

    Directory of Open Access Journals (Sweden)

    Samya El-Ogbi

    2011-05-01

    Full Text Available Cochlear implantation has become established worldwide as a safe and effective method of auditory rehabilitation of selected severely and profound deaf children and adults. Over 100,000 patients have received cochlear implants worldwide with the paediatric population proving to be the main beneficiaries. The Libyan cochlear implant programme was set up in 2004. Data relating to the patients who received cochlear implantation at Tripoli Medical Centre between October 2007 and February 2010 were analysed. Implant operations were performed on 37 patients. All patients received Med-El SONATATI 100 devices. Thirty-four (91.9% of these patients were children, whilst three (8.1% were adults. Combined, congenital hearing loss (56.8% and perinatal/neonatal (29.7% were the two main aetiological factors in children. Seventeen patients (45.9% had a positive family history of deafness. Sixteen patients (43.2% were born to blood-related parents. The overall rate of minor and major complications was 16.2%, which is comparable to previous studies.

  5. Libyan cochlear implant programme: achievements, difficulties, and future goals.

    Science.gov (United States)

    Salamat, Ali; Esriti, Anwer; Ehtuish, Asia; El-Ogbi, Samya

    2011-01-01

    Cochlear implantation has become established worldwide as a safe and effective method of auditory rehabilitation of selected severely and profound deaf children and adults. Over 100,000 patients have received cochlear implants worldwide with the paediatric population proving to be the main beneficiaries. The Libyan cochlear implant programme was set up in 2004. Data relating to the patients who received cochlear implantation at Tripoli Medical Centre between October 2007 and February 2010 were analysed. Implant operations were performed on 37 patients. All patients received Med-El SONATA(TI) (100) devices. Thirty-four (91.9%) of these patients were children, whilst three (8.1%) were adults. Combined, congenital hearing loss (56.8%) and perinatal/neonatal (29.7%) were the two main aetiological factors in children. Seventeen patients (45.9%) had a positive family history of deafness. Sixteen patients (43.2%) were born to blood-related parents. The overall rate of minor and major complications was 16.2%, which is comparable to previous studies.

  6. Modulation of cochlear tuning by low-frequency sound

    NARCIS (Netherlands)

    Klis, J.F.L.; Prijs, V.F.; Latour, J.B.; Smoorenburg, G.F.

    1988-01-01

    An intense, low-frequency tone (about 30 Hz) modulates the sensitivity of the inner ear to high-frequency stimulation. This modulation is correlated with the displacement of the basilar membrane. The findings suggest that the modulation may also affect cochlear tuning. We have investigated

  7. The Acceptance of Background Noise in Adult Cochlear Implant Users

    Science.gov (United States)

    Plyler, Patrick N.; Bahng, Junghwa; von Hapsburg, Deborah

    2008-01-01

    Purpose: The purpose of this study was to determine (a) if acceptable noise levels (ANLs) are different in cochlear implant (CI) users than in listeners with normal hearing, (b) if ANLs are related to sentence reception thresholds in noise in CI users, and (c) if ANLs and subjective outcome measures are related in CI users. Method: ANLs and the…

  8. A software tool for analyzing multichannel cochlear implant signals.

    Science.gov (United States)

    Lai, Wai Kong; Bögli, Hans; Dillier, Norbert

    2003-10-01

    A useful and convenient means to analyze the radio frequency (RF) signals being sent by a speech processor to a cochlear implant would be to actually capture and display them with appropriate software. This is particularly useful for development or diagnostic purposes. sCILab (Swiss Cochlear Implant Laboratory) is such a PC-based software tool intended for the Nucleus family of Multichannel Cochlear Implants. Its graphical user interface provides a convenient and intuitive means for visualizing and analyzing the signals encoding speech information. Both numerical and graphic displays are available for detailed examination of the captured CI signals, as well as an acoustic simulation of these CI signals. sCILab has been used in the design and verification of new speech coding strategies, and has also been applied as an analytical tool in studies of how different parameter settings of existing speech coding strategies affect speech perception. As a diagnostic tool, it is also useful for troubleshooting problems with the external equipment of the cochlear implant systems.

  9. The acquisition of personal pronouns in cochlear-implanted children

    NARCIS (Netherlands)

    Verbist, Annemie Josee Jozef

    2010-01-01

    Today, many deaf children can be given access to oral language thanks to a cochlear implant, a surgically implanted electronic device that provides a sense of sound thanks to electric stimulation of the auditory nerve. In this study, the acquisition of personal pronouns is considered to be a measure

  10. Predictors of Spoken Language Development Following Pediatric Cochlear Implantation

    NARCIS (Netherlands)

    Johan Frijns; prof. Dr. Louis Peeraer; van Wieringen; Ingeborg Dhooge; Vermeulen; Jan Brokx; Tinne Boons; Wouters

    2012-01-01

    Objectives: Although deaf children with cochlear implants (CIs) are able to develop good language skills, the large variability in outcomes remains a significant concern. The first aim of this study was to evaluate language skills in children with CIs to establish benchmarks. The second aim was to

  11. Imaging of acquired non-traumatic cochlear lesions: iconographic essay

    International Nuclear Information System (INIS)

    Garcia, Marcelo de Mattos; Gonzaga, Juliana Gontijo

    2006-01-01

    Different non-traumatic acquired cochlear lesions are shown in this article with imaging methods. They may be responsible for neuro sensorial hearing loss or vertigo. The method of choice is computed tomography when evaluating the osseous labyrinth whereas magnetic resonance imaging has superior resolution in the studies of the membranaceous labyrinth. (author)

  12. Challenges in Improving Cochlear Implant Performance and Accessibility.

    Science.gov (United States)

    Zeng, Fan-Gang

    2017-08-01

    Here I identify two gaps in cochlear implants that have been limiting their performance and acceptance. First, cochlear implant performance has remained largely unchanged, despite the number of publications tripling per decade in the last 30 years. Little has been done so far to address a fundamental limitation in the electrode-to-neuron interface, with the electrode size being a thousand times larger than the neuron diameter while the number of electrodes being a thousand times less. Both the small number and the large size of electrodes produce broad spatial activation and poor frequency resolution that limit current cochlear implant performance. Second, a similarly rapid growth in cochlear implant volume has not produced an expected decrease in unit price in the same period. The high cost contributes to low market penetration rate, which is about 20% in developed countries and less than 1% in developing countries. I will discuss changes needed in both research strategy and business practice to close the gap between prosthetic and normal hearing as well as that between haves and have-nots.

  13. Theory of Mind and Language in Children with Cochlear Implants

    Science.gov (United States)

    Remmel, Ethan; Peters, Kimberly

    2009-01-01

    Thirty children with cochlear implants (CI children), age range 3-12 years, and 30 children with normal hearing (NH children), age range 4-6 years, were tested on theory of mind and language measures. The CI children showed little to no delay on either theory of mind, relative to the NH children, or spoken language, relative to hearing norms. The…

  14. Reading comprehension of deaf children with cochlear implants

    NARCIS (Netherlands)

    Vermeulen, A.M.; Bon, W.H.J. van; Schreuder, R.; Knoors, H.E.T.; Snik, A.F.M.

    2007-01-01

    The reading comprehension and visual word recognition in 50 deaf children and adolescents with at least 3 years of cochlear implant (0) use were evaluated. Their skills were contrasted with reference data of 500 deaf children without CIs. The reading comprehension level in children with CIs was

  15. The Relationship Between Cochlear Implants and Deaf Identity

    DEFF Research Database (Denmark)

    Chapman, Madeleine; Dammeyer, Jesper

    2017-01-01

    from a Danish national survey of deaf adults, the authors examined the significance of having (or not having) a CI in regard to identity (categorized as deaf, hearing, bicultural, and marginal) and various related factors concerning social participation and experiences of being deaf. Cochlear...

  16. Motor Development of Deaf Children with and without Cochlear Implants

    Science.gov (United States)

    Gheysen, Freja; Loots, Gerrit; Van Waelvelde, Hilde

    2008-01-01

    The purpose of this study was to investigate the impact of a cochlear implant (CI) on the motor development of deaf children. The study involved 36 mainstreamed deaf children (15 boys, 21 girls; 4- to 12-years old) without any developmental problems. Of these children, 20 had been implanted. Forty-three hearing children constituted a comparison…

  17. [Cochlear implant in patients with congenital malformation of inner ear].

    Science.gov (United States)

    Han, Dong-yi; Wu, Wen-ming; Xi, Xin; Huang, De-liang; Yang, Wei-yan

    2004-02-01

    To study surgical difficulty and key of the cochlear implant in patients with congenital malformation of inner ear. The cochlear implantations were performed in our department from Jan. 2001 to Apr. 2003 for 18 patients with the malformation of inner ear. In this series, there were 11 cases of large vestibular aqueduct syndrome (LVAS), 3 cases of Waardenberg syndrome, 3 cases of Mondini malformation, and 1 case of Usher syndrome. All 18 patients accepted the Nucleus 24-channel cochlear implantations, including Nucleus straight electrode in 13 cases but Contour implantation in 5 cases of LVAS. During operations, leakage of perilymph but not cerebrospinal fluid (CSF) from the open of scala tympani occurred in 11 cases of LVAS, however, the electrode was inserted successfully. The abnormalities of round window occurred in one of 3 cases of Waardenberg syndrome and 3 cases of Mondini malformation, respectively. The cochlear implant could be conducted successfully for the LVAS, and the postoperative effect was same as the ones for the deafness persons with normal development of inner ear. However, for the patients with Mondini syndrome and common cavity, it is important to accurately assess the extent of abnormalities in the inner ear and accompanied malformation before operation, and to evaluate the full extent of difficulties of the operation in order to minimize the risk of CSF leakage and meningitis.

  18. Mismatch Negativity Based Neurofeedback for Cochlear Implant Users

    NARCIS (Netherlands)

    Luckmann, Annika; Başkent, Deniz; Jolij, Jacob

    2015-01-01

    Cochlear implant (CI) users experience great difficulty when it comes to pitch discrimination. This leads to problems during daily interactions, due to poor speech perception, but also a very low pleasure ratings for music. Improving pitch perception and discrimination in CI users would improve

  19. Cochlear Damage Affects Neurotransmitter Chemistry in the Central Auditory System

    Directory of Open Access Journals (Sweden)

    Donald Albert Godfrey

    2014-11-01

    Full Text Available Tinnitus, the perception of a monotonous sound not actually present in the environment, affects nearly 20% of the population of the United States. Although there has been great progress in tinnitus research over the past 25 years, the neurochemical basis of tinnitus is still poorly understood. We review current research about the effects of various types of cochlear damage on the neurotransmitter chemistry in the central auditory system and document evidence that different changes in this chemistry can underlie similar behaviorally measured tinnitus symptoms. Most available data have been obtained from rodents following cochlear damage produced by cochlear ablation, loud sound, or ototoxic drugs. Effects on neurotransmitter systems have been measured as changes in neurotransmitter level, synthesis, release, uptake, and receptors. In this review, magnitudes of changes are presented for neurotransmitter-related amino acids, acetylcholine, and serotonin. A variety of effects have been found in these studies that may be related to animal model, survival time, type of cochlear damage, or methodology. The overall impression from the evidence presented is that any imbalance of neurotransmitter-related chemistry could disrupt auditory processing in such a way as to produce tinnitus.

  20. Age at implantation and auditory memory in cochlear implanted children.

    Science.gov (United States)

    Mikic, B; Miric, D; Nikolic-Mikic, M; Ostojic, S; Asanovic, M

    2014-05-01

    Early cochlear implantation, before the age of 3 years, provides the best outcome regarding listening, speech, cognition an memory due to maximal central nervous system plasticity. Intensive postoperative training improves not only auditory performance and language, but affects auditory memory as well. The aim of this study was to discover if the age at implantation affects auditory memory function in cochlear implanted children. A total of 50 cochlear implanted children aged 4 to 8 years were enrolled in this study: early implanted (1-3y) n = 27 and late implanted (4-6y) n = 23. Two types of memory tests were used: Immediate Verbal Memory Test and Forward and Backward Digit Span Test. Early implanted children performed better on both verbal and numeric tasks of auditory memory. The difference was statistically significant, especially on the complex tasks. Early cochlear implantation, before the age of 3 years, significantly improve auditory memory and contribute to better cognitive and education outcomes.

  1. Classroom performance of children with cochlear implants in mainstream education.

    NARCIS (Netherlands)

    Damen, G.W.J.A.; Oever-Goltstein, M.H. van den; Langereis, M.C.; Chute, P.M.; Mylanus, E.A.M.

    2006-01-01

    OBJECTIVES: We compared classroom performance of children with a cochlear implant (CI) with that of their normal-hearing peers in mainstream education. METHODS: Thirty-two CI children in mainstream education, congenitally or prelingually deaf, participated in this study, as did 37 hearing

  2. Interaction of tinnitus suppression and hearing ability after cochlear implantation.

    Science.gov (United States)

    Wang, Qian; Li, Jia-Nan; Lei, Guan-Xiong; Chen, Dai-Shi; Wang, Wei-Ze; Chen, Ai-Ting; Mong, Meng-Di; Li, Sun; Jiao, Qing-Shan; Yang, Shi-Ming

    2017-10-01

    To study the postoperative impact of cochlear implants (CIs) on tinnitus, as well as the impact of tinnitus on speech recognition with CI switched on. Fifty-two postlingual deafened CI recipients (21 males and 31 females) were assessed using an established Tinnitus Characteristics Questionnaire and Tinnitus Handicap Inventory (THI) before and after cochlear implantation. The tinnitus loudness was investigated when CI was switched on and off in CI recipients with persistent tinnitus. The relation between tinnitus loudness and recipients' satisfaction of cochlear implantation was analyzed by the visual analogue scale (VAS) score. With CI 'OFF', 42 CI recipients experienced tinnitus postimplant ipsilaterally and 44 contralaterally. Tinnitus was totally suppressed ipsilateral to the CI with CI 'ON' in 42.9%, partially suppressed in 42.9%, unchanged in 11.9% and aggravated in 2.4%. Tinnitus was totally suppressed contralaterally with CI 'ON' in 31.8% of CI recipients, partially suppressed in 47.7%, unchanged in 20.5%. Pearson correlation analysis showed that tinnitus loudness and the results of cochlear implant patients satisfaction was negatively correlated (r = .674, p tinnitus. The tinnitus loudness may affect patients' satisfaction with the use of CI.

  3. Simultaneous Communication and Cochlear Implants in the Classroom?

    NARCIS (Netherlands)

    Blom, H.C.; Marschark, M.

    2015-01-01

    This study was designed to evaluate the potential of simultaneous communication (sign and speech together) to support classroom learning by college students who use cochlear implants (CIs). Metacognitive awareness of learning also was evaluated. A within-subjects design involving 40 implant users

  4. Simultaneous communication supports learning in noise by cochlear implant users

    NARCIS (Netherlands)

    Blom, H.C.; Marschark, M.; Machmer, E.

    2017-01-01

    Objectives: This study sought to evaluate the potential of using spoken language and signing together (simultaneous communication, SimCom, sign-supported speech) as a means of improving speech recognition, comprehension, and learning by cochlear implant (CI) users in noisy contexts.Methods: Forty

  5. Perception of Cantonese Lexical Tones by Pediatric Cochlear Implant Users

    Science.gov (United States)

    Holt, Colleen M.; Lee, Kathy Y. S.; Dowell, Richard C.; Vogel, Adam P.

    2018-01-01

    Purpose: The purpose of this study is to assess Cantonese word recognition and the discrimination of Cantonese tones with manipulated contours by child and adolescent cochlear implant (CI) users and a group of peers with normal hearing (NH). It was hypothesized that the CI users would perform more poorly than their counterparts with NH in both…

  6. Audiological outcomes of cochlear implantation in Waardenburg Syndrome

    Directory of Open Access Journals (Sweden)

    Magalhães, Ana Tereza de Matos

    2014-01-01

    Full Text Available Introduction: The most relevant clinical symptom in Waardenburg syndrome is profound bilateral sensorioneural hearing loss. Aim: To characterize and describe hearing outcomes after cochlear implantation in patients with Waardenburg syndrome to improve preoperative expectations. Method: This was an observational and retrospective study of a series of cases. Children who were diagnosed with Waardenburg syndrome and who received a multichannel cochlear implant between March 1999 and July 2012 were included in the study. Intraoperative neural response telemetry, hearing evaluation, speech perception, and speech production data before and after surgery were assessed. Results: During this period, 806 patients received a cochlear implant and 10 of these (1.2% were diagnosed with Waardenburg syndrome. Eight of the children received a Nucleus 24® implant and 1 child and 1 adult received a DigiSonic SP implant. The mean age at implantation was 44 months among the children. The average duration of use of a cochlear implant at the time of the study was 43 months. Intraoperative neural responses were present in all cases. Patients who could use the speech processor effectively had a pure tone average of 31 dB in free-field conditions. In addition, the MUSS and MAIS questionnaires revealed improvements in speech perception and production. Four patients did not have a good outcome, which might have been associated with ineffective use of the speech processor. Conclusion: Despite the heterogeneity of the group, patients with Waardenburg syndrome who received cochlear implants were found to have hearing thresholds that allowed access to speech sounds. However, patients who received early intervention and rehabilitation showed better evolution of auditory perception.

  7. Audiological outcomes of cochlear implantation in Waardenburg Syndrome.

    Science.gov (United States)

    Magalhães, Ana Tereza de Matos; Samuel, Paola Angélica; Goffi-Gomez, Maria Valeria Schimdt; Tsuji, Robinson Koji; Brito, Rubens; Bento, Ricardo Ferreira

    2013-07-01

     The most relevant clinical symptom in Waardenburg syndrome is profound bilateral sensorioneural hearing loss.  To characterize and describe hearing outcomes after cochlear implantation in patients with Waardenburg syndrome to improve preoperative expectations.  This was an observational and retrospective study of a series of cases. Children who were diagnosed with Waardenburg syndrome and who received a multichannel cochlear implant between March 1999 and July 2012 were included in the study. Intraoperative neural response telemetry, hearing evaluation, speech perception, and speech production data before and after surgery were assessed.  During this period, 806 patients received a cochlear implant and 10 of these (1.2%) were diagnosed with Waardenburg syndrome. Eight of the children received a Nucleus 24(®) implant and 1 child and 1 adult received a DigiSonic SP implant. The mean age at implantation was 44 months among the children. The average duration of use of a cochlear implant at the time of the study was 43 months. Intraoperative neural responses were present in all cases. Patients who could use the speech processor effectively had a pure tone average of 31 dB in free-field conditions. In addition, the MUSS and MAIS questionnaires revealed improvements in speech perception and production. Four patients did not have a good outcome, which might have been associated with ineffective use of the speech processor.  Despite the heterogeneity of the group, patients with Waardenburg syndrome who received cochlear implants were found to have hearing thresholds that allowed access to speech sounds. However, patients who received early intervention and rehabilitation showed better evolution of auditory perception.

  8. Electroacoustic verification of frequency modulation systems in cochlear implant users.

    Science.gov (United States)

    Fidêncio, Vanessa Luisa Destro; Jacob, Regina Tangerino de Souza; Tanamati, Liége Franzini; Bucuvic, Érika Cristina; Moret, Adriane Lima Mortari

    2017-12-26

    The frequency modulation system is a device that helps to improve speech perception in noise and is considered the most beneficial approach to improve speech recognition in noise in cochlear implant users. According to guidelines, there is a need to perform a check before fitting the frequency modulation system. Although there are recommendations regarding the behavioral tests that should be performed at the fitting of the frequency modulation system to cochlear implant users, there are no published recommendations regarding the electroacoustic test that should be performed. Perform and determine the validity of an electroacoustic verification test for frequency modulation systems coupled to different cochlear implant speech processors. The sample included 40 participants between 5 and 18 year's users of four different models of speech processors. For the electroacoustic evaluation, we used the Audioscan Verifit device with the HA-1 coupler and the listening check devices corresponding to each speech processor model. In cases where the transparency was not achieved, a modification was made in the frequency modulation gain adjustment and we used the Brazilian version of the "Phrases in Noise Test" to evaluate the speech perception in competitive noise. It was observed that there was transparency between the frequency modulation system and the cochlear implant in 85% of the participants evaluated. After adjusting the gain of the frequency modulation receiver in the other participants, the devices showed transparency when the electroacoustic verification test was repeated. It was also observed that patients demonstrated better performance in speech perception in noise after a new adjustment, that is, in these cases; the electroacoustic transparency caused behavioral transparency. The electroacoustic evaluation protocol suggested was effective in evaluation of transparency between the frequency modulation system and the cochlear implant. Performing the adjustment of

  9. Barriers to pediatric cochlear implantation: A parental survey.

    Science.gov (United States)

    Yang, Charles Q; Reilly, Brian K; Preciado, Diego A

    2018-01-01

    This study aims to (1) determine barriers in the pediatric cochlear implantation process specific to publicly insured patients, wherein delayed implantation has been reported, and (2) compare the perceived barriers between publicly and privately insured patients. Tertiary care cochlear implantation center at academic pediatric hospital. Cross-sectional survey, retrospective chart review. The validated, 39 item Barriers to Care Questionnaire was administered to the parents of 80 recipients of cochlear implantation by two surgeons between 2013 and 2016. Survey results and diagnosis to implant interval were compared based on public or private insurance status. Two-tailed Mann-Whitney and Fisher's exact test was used for statistical analysis. Of 110 cochlear implants, 27 of 80 (34%) English-speaking parents completed the survey. 15 were privately insured and 12 were publicly insured. 23 of 27 respondents received cochlear implantation for pre-lingual sensorineural hearing loss. Publicly insured patients had significantly longer median time from diagnosis to implant than privately insured (19 vs. 8 mo, p = 0.01). The three worst scoring barrier categories for privately insured families in order were Pragmatics, Expectations, and Marginalization, whereas for publicly insured families it was Pragmatics, Skills, and Expectations. The worst scoring question for privately insured patients was "Having to take time off work". For the publicly insured, it was "Lack of communication." Privately insured patients reported more barriers on the Barriers to Care Questionnaire than publicly insured patients did. Although pragmatics was the worst-scoring barrier category for both groups, difficulties found on the survey ranked differently for each group. This information can help providers address disparities and access barriers for vulnerable patients. Published by Elsevier B.V.

  10. A prospective study evaluating cochlear implant management skills: development and validation of the Cochlear Implant Management Skills survey.

    Science.gov (United States)

    Bennett, R J; Jayakody, D M P; Eikelboom, R H; Taljaard, D S; Atlas, M D

    2016-02-01

    To investigate the ability of cochlear implant (CI) recipients to physically handle and care for their hearing implant device(s) and to identify factors that may influence skills. To assess device management skills, a clinical survey was developed and validated on a clinical cohort of CI recipients. Survey development and validation. A prospective convenience cohort design study. Specialist hearing implant clinic. Forty-nine post-lingually deafened, adult CI recipients, at least 12 months postoperative. Survey test-retest reliability, interobserver reliability and responsiveness. Correlations between management skills and participant demographic, audiometric, clinical outcomes and device factors. The Cochlear Implant Management Skills survey was developed, demonstrating high test-retest reliability (0.878), interobserver reliability (0.972) and responsiveness to intervention (skills training) [t(20) = -3.913, P = 0.001]. Cochlear Implant Management Skills survey scores range from 54.69% to 100% (mean: 83.45%, sd: 12.47). No associations were found between handling skills and participant factors. This is the first study to demonstrate a range in cochlear implant device handling skills in CI recipients and offers clinicians and researchers a tool to systematically and objectively identify shortcomings in CI recipients' device handling skills. © 2015 John Wiley & Sons Ltd.

  11. Eponyms in cardiothoracic radiology: Part I. Neoplasms.

    Science.gov (United States)

    Mohammed, Tan-Lucien H; Saettele, Megan R; Saettele, Timothy; Patel, Vikas; Kanne, Jeffrey P

    2014-01-01

    Eponyms serve the purpose of honoring individuals who have made important observations and discoveries. As with other fields of medicine, eponyms are frequently encountered in radiology, particularly in chest radiology. However, inappropriate use of an eponym may lead to potentially dangerous miscommunication. Moreover, an eponym may honor the incorrect person or a person who falls into disrepute. Despite their limitations, eponyms are still widespread in medical literature. Furthermore, in some circumstances, more than one individual may have contributed to the description or discovery of a particular anatomical structure or disease, whereas in others, an eponym may have been incorrectly applied initially and propagated for years in medical literature. Nevertheless, radiologic eponyms are a means of honoring those who have made lasting contributions to the field of radiology, and familiarity with these eponyms is critical for proper reporting and accurate communication. In addition, the acquisition of some historical knowledge about those whose names are associated with various structures or pathologic conditions conveys a sense of humanity in the field of medicine. In this article, the first of a multipart series, the authors discuss a number of chest radiology eponyms as they relate to neoplasms, including relevant clinical and imaging features, as well biographic information of the respective eponym׳s namesake. Copyright © 2014 Elsevier Inc. All rights reserved.

  12. Comparison of outcomes in a case of bilateral cochlear implantation using devices manufactured by two different implant companies (Cochlear Corporation and Med-El).

    Science.gov (United States)

    Withers, S J; Gibson, W P; Greenberg, S L; Bray, M

    2011-05-01

    This paper reports a case of a patient who has had bilateral cochlear implants that have been manufactured by different cochlear implant companies (Cochlear Corporation and Med-El). Comparison of speech perception tests following single implant insertion and bilateral insertion (3 and 12 months). The patient was also interviewed to obtain a subjective opinion on their quality of hearing. The patient reported that their Med-El implant had better sound quality than their Cochlear Corporation implant. The speech perception tests however failed to show any difference. Despite no difference found with the objective tests hearing is very subjective and therefore the patient's opinion on the quality of sound is important. It is only a matter of time before other patients are fitted with bilateral cochlear implants from different companies and this information should be collated to allow comparison between manufacturers.

  13. Research on photoconductor radiological sensors

    International Nuclear Information System (INIS)

    Beaumont, Francois

    1989-01-01

    Because of the evolution of medical imaging techniques to digital systems, it is necessary to replace radiological film which has many drawbacks, by a detector quite as efficient and quickly giving a digitable signal. The purpose of this thesis is to find new X-ray digital imaging processes using photoconductor materials such as amorphous selenium. After reviewing the principle of direct radiology and functions to be served by the X-ray sensor (i e. detection, memory, assignment, visualization), we explain specification. We especially show the constraints due to the object to be radio-graphed (condition of minimal exposure), and to the reading signal (electronic noise detection associated with a reading frequency). As a result of this study, a first photoconductor sensor could be designed. Its principle is based on photo carrier trapping at dielectric-photoconductor structure interface. The reading system needs the scanning of a laser beam upon the sensor surface. The dielectric-photoconductor structure enabled us to estimate the possibilities offered by the sensor and to build a complete x-ray imaging system. The originality of thermos-dielectric sensor, that was next studied, is to allow a thermal assignment reading. The chosen system consists in varying the ferroelectric polymer capacity whose dielectric permittivity is weak at room temperature. The thermo-dielectric material was studied by thermal or Joule effect stimulation. During our experiments, trapping was found in a sensor made of amorphous selenium between two electrodes. This new effect was performed and enabled us to expose a first interpretation. Eventually, the comparison of these new sensor concepts with radiological film shows the advantage of the proposed solution. (author) [fr

  14. The Future of Radiology

    Directory of Open Access Journals (Sweden)

    Alexander R. Margulis

    2011-07-01

    Full Text Available It has been my good fortune to live and practice radiology during a long period of momentous change – to see the transformation of the discipline from a supportive service into a mainstream, essential branch of clinical medicine. I remember wearing red goggles to adapt my vision before performing fluoroscopy; observing the horrible, now thankfully obsolete, practice of ventriculography, which was considered advanced neuroradiology; and performing other, now rarely prescribed procedures, such as double-contrast barium enemas and intravenous pyelography. Witnessing the beginnings of interventional radiology, I suggested its name in an editorial. I also had the good fortune to see the introduction of computed tomography (CT and a technology first known as nuclear magnetic resonance imaging. Together with fellow members of a committee of the American College of Radiology and editors of prestigious radiological journals, I took part in changing the name of the latter modality to MRI, freeing it from threatening implications. Looking back on these experiences, one lesson stands out above all: Innovation and transformation never cease. Looking forward, it is clear that radiology, along with the rest of medicine, is now undergoing further momentous changes that will affect the future of all those already practicing as well as those yet to start their careers.

  15. [Digital signal processing of a novel neuron discharge model stimulation strategy for cochlear implants].

    Science.gov (United States)

    Yang, Yiwei; Xu, Yuejin; Miu, Jichang; Zhou, Linghong; Xiao, Zhongju

    2012-10-01

    To apply the classic leakage integrate-and-fire models, based on the mechanism of the generation of physiological auditory stimulation, in the information processing coding of cochlear implants to improve the auditory result. The results of algorithm simulation in digital signal processor (DSP) were imported into Matlab for a comparative analysis. Compared with CIS coding, the algorithm of membrane potential integrate-and-fire (MPIF) allowed more natural pulse discharge in a pseudo-random manner to better fit the physiological structures. The MPIF algorithm can effectively solve the problem of the dynamic structure of the delivered auditory information sequence issued in the auditory center and allowed integration of the stimulating pulses and time coding to ensure the coherence and relevance of the stimulating pulse time.

  16. Emergency radiological monitoring and analysis: Federal Radiological Monitoring and Assessment Center

    International Nuclear Information System (INIS)

    Thome, D.J.

    1995-01-01

    The US Federal Radiological Emergency Response Plan (FRERP) provides the framework for integrating the various Federal agencies responding to a major radiological emergency. The FRERP authorizes the creation of the Federal Radiological Monitoring and Assessment Center (FRMAC), which is established to coordinate all Federal agencies involved in the monitoring and assessment of the off-site radiological conditions in support of the impacted State(s) and the Lead Federal Agency (LFA). Within the FRMAC, the Monitoring and Analysis Division (M ampersand A) is responsible for coordinating all FRMAC assets involved in conducting a comprehensive program of environmental monitoring, sampling, radioanalysis, and quality assurance. To assure consistency, completeness, and the quality of the data produced, a methodology and procedures manual is being developed. This paper discusses the structure, assets, and operations of the FRMAC M ampersand A and the content and preparation of the manual

  17. Comparison of bimodal and bilateral cochlear implant users on speech recognition with competing talker, music perception, affective prosody discrimination, and talker identification.

    Science.gov (United States)

    Cullington, Helen E; Zeng, Fan-Gang

    2011-02-01

    Despite excellent performance in speech recognition in quiet, most cochlear implant users have great difficulty with speech recognition in noise, music perception, identifying tone of voice, and discriminating different talkers. This may be partly due to the pitch coding in cochlear implant speech processing. Most current speech processing strategies use only the envelope information; the temporal fine structure is discarded. One way to improve electric pitch perception is to use residual acoustic hearing via a hearing aid on the nonimplanted ear (bimodal hearing). This study aimed to test the hypothesis that bimodal users would perform better than bilateral cochlear implant users on tasks requiring good pitch perception. Four pitch-related tasks were used. 1. Hearing in Noise Test (HINT) sentences spoken by a male talker with a competing female, male, or child talker. 2. Montreal Battery of Evaluation of Amusia. This is a music test with six subtests examining pitch, rhythm and timing perception, and musical memory. 3. Aprosodia Battery. This has five subtests evaluating aspects of affective prosody and recognition of sarcasm. 4. Talker identification using vowels spoken by 10 different talkers (three men, three women, two boys, and two girls). Bilateral cochlear implant users were chosen as the comparison group. Thirteen bimodal and 13 bilateral adult cochlear implant users were recruited; all had good speech perception in quiet. There were no significant differences between the mean scores of the bimodal and bilateral groups on any of the tests, although the bimodal group did perform better than the bilateral group on almost all tests. Performance on the different pitch-related tasks was not correlated, meaning that if a subject performed one task well they would not necessarily perform well on another. The correlation between the bimodal users' hearing threshold levels in the aided ear and their performance on these tasks was weak. Although the bimodal cochlear

  18. Reactive neurogenesis and down-regulation of the potassium-chloride cotransporter KCC2 in the cochlear nuclei after cochlear deafferentation

    Directory of Open Access Journals (Sweden)

    Brahim Tighilet

    2016-08-01

    Full Text Available While many studies have been devoted to investigating the homeostatic plasticity triggered by cochlear hearing loss, the cellular and molecular mechanisms involved in these central changes remain elusive. In the present study, we investigated the possibility of reactive neurogenesis after unilateral cochlear nerve section in the cochlear nucleus of cats. We found a strong cell proliferation in all the cochlear nucleus sub-divisions ipsilateral to the lesion. Most of the newly generated cells survive up to one month after cochlear deafferentation in all cochlear nuclei (except the dorsal cochlear nucleus and give rise to a variety of cell types, i.e. microglial cells, astrocytes and neurons. Interestingly, many of the newborn neurons had an inhibitory (GABAergic phenotype. This result is intriguing since sensory deafferentation is usually accompanied by enhanced excitation, consistent with a reduction in central inhibition. The membrane potential effect of GABA depends, however, on the intra-cellular chloride concentration, which is maintained at low levels in adults by the potassium chloride co-transporter KCC2. The KCC2 density on the plasma membrane of neurons was then assessed after cochlear deafferentation in the cochlear nuclei ipsilateral and contralateral to the lesion. Cochlear deafferentation is accompanied by a strong down-regulation of KCC2 ipsilateral to the lesion at 3 and 30 days post-lesion. This study suggests that reactive neurogenesis and downregulation of KCC2 is part of the vast repertoire involved in homeostatic plasticity triggered by hearing loss. These central changes may also play a role in the generation of tinnitus and hyperacusis.

  19. [Inspecting the cochlear scala tympanic with flexible and semi-flexible micro-endoscope].

    Science.gov (United States)

    Zhang, Daoxcing; Zhang, Yankun

    2006-02-01

    Flexible and semi-flexible micro-endoscopes were used in cochlear scala tympani inspection , to explore their application in inner ear examination. Fifteen profound hearing loss patients preparing for cochlear implant were included in this study. During the operation, micro-endoscopy was performed after opening the cochlear scala tympani. And 1 mm diameter semi-flexible micro-endoscope could go as deep as 9 mm into the cochlear scala tympani, while 0. 5 mm diameter flexible micro-endoscope could go as deep as 25 mm. The inspecting results were compared with video recording. Using 0.5 mm flexible micro-endoscope, we canould check cochlear scala tympani with depth range of 15-25 mm, but the video imaging was not clear enough to examine the microstructure in the cochlear. With 1 mm diameter semi-flexible micro-endoscope, we could reach 9 mm deep into the cochlear. During the examination, we found 3 cases with calcification deposit in osseous spiral lamina, l case with granulation tissue in the lateral wall of scala tympani, no abnormal findings in the other 11 cases. Inspecting the cochlear scala tympani with 0.5 mm flexible micro-endoscope, even though we can reach the second circuit of the cochlear, it is difficult to find the pathology in the cochlear because of the poor video imaging. With 1 mm semi-flexible micro-endoscope, we can identify the microstructure of the cochlear clearly and find the pathologic changes, but the inserting depth was limited to 9 mm with limitation to examine the whole cochlear.

  20. Implementation of a remote system for monitoring of radiological areas of radiological areas

    International Nuclear Information System (INIS)

    Velazquez E, Walter; Galuppo G, Emiliano; Gutierrez G, Jorge; Reyes R, Jerson

    2008-01-01

    use of radioactive sources, for instance, the level nuclear test, nuclear densimeter and other of this kinds of instruments are growing up in the industrial process, the reason for this selection is the long life time, the precision of his measures, and the low maintenance. The use of these instruments in industries or mining where the workspace is limited, and people are working in the place, it's established the necessity of the radiological supervisor on plant, and radiological protection do it. In this context since 2006, the Chilean Nuclear Commission has been development a structural system and introduced this system called Sistema de Monitoreo de Area Radiologico Remoto (Remote Radiological Area Monitoring System english) SMARR-CCHEN, on Chilean Mining and industries for to help to radiological protection and work together with the supervisors on plants in emergency case. The SMARR system works on pyramidal structure, where the areas on the plant are the base of the recollect information. The HW monitoring the static sources on areas from called monitoring points, and SW based on LabView shows the radiological variables 'on line' for each radioactive source on the monitor in the area control room respective, the information is replicated on the SMARR data center on CCHEN, and the official of radiological protect interview on line with the supervisor plant in the data analysis. Conclusion: Resulting monitoring indicates a reasonable radiological profile for each facility under survey; The development of SMARR system for the next years, will optimized the radiation protection, the process of data acquisition, and to development of some important tools for to that help to radiological safety; The final results are used for reference levels for facilities; The introduction of SMARR system in the industry to allow the radiological emergencies control, it's showing at user on-line the radiological variables. (author)

  1. Anesthesia for radiologic procedures

    International Nuclear Information System (INIS)

    Forestner, J.E.

    1987-01-01

    Anesthetic techniques for neurodiagnostic studies and radiation therapy have been recently reviewed, but anesthetic involvement in thoracic and abdominal radiology has received little attention. Patient reactions to radiologic contrast media may be of concern to the anesthesiologist, who is often responsible for injecting these agents during diagnostic procedures, and thus is included in this discussion. Finally, the difficulties of administering anesthesia for magnetic resonance imaging (MRI) scans are outlined, in an effort to help anesthesiologist to anticipate problems with this new technologic development. Although there are very few indications for the use of general anesthesia for diagnostic radiologic studies in adults, most procedures performed with children, the mentally retarded, or the combative adult require either heavy sedation or general anesthesia. In selecting an anesthetic technique for a specific procedure, both the patient's disease process and the requirements of the radiologist must be carefully balanced

  2. Organizational decentralization in radiology.

    Science.gov (United States)

    Aas, I H Monrad

    2006-01-01

    At present, most hospitals have a department of radiology where images are captured and interpreted. Decentralization is the opposite of centralization and means 'away from the centre'. With a Picture Archiving and Communication System (PACS) and broadband communications, transmitting radiology images between sites will be far easier than before. Qualitative interviews of 26 resource persons were performed in Norway. There was a response rate of 90%. Decentralization of radiology interpretations seems less relevant than centralization, but several forms of decentralization have a role to play. The respondents mentioned several advantages, including exploitation of capacity and competence. They also mentioned several disadvantages, including splitting professional communities and reduced contact between radiologists and clinicians. With the new technology decentralization and centralization of image interpretation are important possibilities in organizational change. This will be important for the future of teleradiology.

  3. Radiology education: a radiology curriculum for all medical students?

    NARCIS (Netherlands)

    Zwaan, Laura; Kok, E.M.; van der Gijp, Anouk

    2017-01-01

    Diagnostic errors in radiology are frequent and can cause severe patient harm. Despite large performance differences between radiologists and non-radiology physicians, the latter often interpret medical images because electronic health records make images available throughout the hospital. Some

  4. Radiological incidents in radiotherapy

    International Nuclear Information System (INIS)

    Hobzova, L.; Novotny, J.

    2008-01-01

    In many countries a reporting system of radiological incidents to national regulatory body exists and providers of radiotherapy treatment are obliged to report all major and/or in some countries all incidents occurring in institution. State Office for Nuclear Safety (SONS) is providing a systematic guidance for radiotherapy departments from 1997 by requiring inclusion of radiation safety problems into Quality assurance manual, which is the basic document for obtaining a license of SONS for handling with sources of ionizing radiation. For that purpose SONS also issued the recommendation 'Introduction of QA system for important sources in radiotherapy-radiological incidents' in which the radiological incidents are defined and the basic guidance for their classification (category A, B, C, D), investigation and reporting are given. At regular periods the SONS in co-operation with radiotherapy centers is making a survey of all radiological incidents occurring in institutions and it is presenting obtained information in synoptic communication (2003 Motolske dny, 2005 Novy Jicin). This presentation is another summary report of radiological incidents that occurred in our radiotherapy institutions during last 3 years. Emphasis is given not only to survey and statistics, but also to analysis of reasons of the radiological incidents and to their detection and prevention. Analyses of incidents in radiotherapy have led to a much broader understanding of incident causation. Information about the error should be shared as early as possible during or after investigation by all radiotherapy centers. Learning from incidents, errors and near misses should be a part of improvement of the QA system in institutions. Generally, it is recommended that all radiotherapy facilities should participate in the reporting, analyzing and learning system to facilitate the dissemination of knowledge throughout the whole country to prevent errors in radiotherapy.(authors)

  5. Radiology's value chain.

    Science.gov (United States)

    Enzmann, Dieter R

    2012-04-01

    A diagnostic radiology value chain is constructed to define its main components, all of which are vulnerable to change, because digitization has caused disaggregation of the chain. Some components afford opportunities to improve productivity, some add value, while some face outsourcing to lower labor cost and to information technology substitutes, raising commoditization risks. Digital image information, because it can be competitive at smaller economies of scale, allows faster, differential rates of technological innovation of components, initiating a centralization-to-decentralization technology trend. Digitization, having triggered disaggregation of radiology's professional service model, may soon usher in an information business model. This means moving from a mind-set of "reading images" to an orientation of creating and organizing information for greater accuracy, faster speed, and lower cost in medical decision making. Information businesses view value chain investments differently than do small professional services. In the former model, producing a better business product will extend image interpretation beyond a radiologist's personal fund of knowledge to encompass expanding external imaging databases. A follow-on expansion with integration of image and molecular information into a report will offer new value in medical decision making. Improved interpretation plus new integration will enrich and diversify radiology's key service products, the report and consultation. A more robust, information-rich report derived from a "systems" and "computational" radiology approach will be facilitated by a transition from a professional service to an information business. Under health care reform, radiology will transition its emphasis from volume to greater value. Radiology's future brightens with the adoption of a philosophy of offering information rather than "reads" for decision making. Staunchly defending the status quo via turf wars is unlikely to constitute a

  6. Radiologic protection in pediatric radiology: ICRP recommendations

    International Nuclear Information System (INIS)

    Sanchez, Ramon; Khong, Pek-Lan; Ringertz, Hans

    2013-01-01

    ICRP has provided an updated overview of radiation protection principles in pediatric radiology. The authors recommend that staff, radiologists, medical physicists and vendors involved in pediatric radiology read this document. For conventional radiography, the report gives advice on patient positioning, immobilization, shielding and appropriate exposure conditions. It describes extensively the use of pulsed fluoroscopy, the importance of limiting fluoroscopy time, and how shielding and geometry must be used to avoid unnecessary radiation to the patient and operator. Furthermore, the use of fluoroscopy in interventional procedures with emphasis on dose reduction to patients and staff is discussed in light of the increasing frequency, complexity and length ofthe procedures. CT is the main reason that medical imaging in several developed countries is the highest annual per capita effective radiation dose from man-made sources. The ICRP report gives extensive descriptions of how CT protocols can be optimized to minimize radiation exposure in pediatric patients. The importance of balancing image quality with acceptable noise in pediatric imaging and the controversies regarding the use of protective shielding in CT are also discussed.

  7. Radiology illustrated. Hepatobiliary and pancreatic radiology

    International Nuclear Information System (INIS)

    Choi, Byung Ihn

    2014-01-01

    Clear, practical guide to the diagnostic imaging of diseases of the liver, biliary tree, gallbladder, pancreas, and spleen. A wealth of carefully selected and categorized illustrations. Highlighted key points to facilitate rapid review. Aid to differential diagnosis. Radiology Illustrated: Hepatobiliary and Pancreatic Radiology is the first of two volumes that will serve as a clear, practical guide to the diagnostic imaging of abdominal diseases. This volume, devoted to diseases of the liver, biliary tree, gallbladder, pancreas, and spleen, covers congenital disorders, vascular diseases, benign and malignant tumors, and infectious conditions. Liver transplantation, evaluation of the therapeutic response of hepatocellular carcinoma, trauma, and post-treatment complications are also addressed. The book presents approximately 560 cases with more than 2100 carefully selected and categorized illustrations, along with key text messages and tables, that will allow the reader easily to recall the relevant images as an aid to differential diagnosis. At the end of each text message, key points are summarized to facilitate rapid review and learning. In addition, brief descriptions of each clinical problem are provided, followed by both common and uncommon case studies that illustrate the role of different imaging modalities, such as ultrasound, radiography, CT, and MRI.

  8. Radiology illustrated. Hepatobiliary and pancreatic radiology

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Byung Ihn (ed.) [Seoul National Univ. Hospital (Korea, Republic of). Dept. of Radiology

    2014-04-01

    Clear, practical guide to the diagnostic imaging of diseases of the liver, biliary tree, gallbladder, pancreas, and spleen. A wealth of carefully selected and categorized illustrations. Highlighted key points to facilitate rapid review. Aid to differential diagnosis. Radiology Illustrated: Hepatobiliary and Pancreatic Radiology is the first of two volumes that will serve as a clear, practical guide to the diagnostic imaging of abdominal diseases. This volume, devoted to diseases of the liver, biliary tree, gallbladder, pancreas, and spleen, covers congenital disorders, vascular diseases, benign and malignant tumors, and infectious conditions. Liver transplantation, evaluation of the therapeutic response of hepatocellular carcinoma, trauma, and post-treatment complications are also addressed. The book presents approximately 560 cases with more than 2100 carefully selected and categorized illustrations, along with key text messages and tables, that will allow the reader easily to recall the relevant images as an aid to differential diagnosis. At the end of each text message, key points are summarized to facilitate rapid review and learning. In addition, brief descriptions of each clinical problem are provided, followed by both common and uncommon case studies that illustrate the role of different imaging modalities, such as ultrasound, radiography, CT, and MRI.

  9. Bilateral cochlear implantation in a patient with bilateral temporal bone fractures.

    Science.gov (United States)

    Chung, Jae Ho; Shin, Myung Chul; Min, Hyun Jung; Park, Chul Won; Lee, Seung Hwan

    2011-01-01

    With the emphasis on bilateral hearing nowadays, bilateral cochlear implantation has been tried out for bilateral aural rehabilitation. Bilateral sensorineural hearing loss caused by head trauma can get help from cochlear implantation. We present the case of a 44-year-old man with bilateral otic capsule violating temporal bone fractures due to head trauma. The patient demonstrated much improved audiometric and psychoacoustic performance after bilateral cochlear implantation. We believe bilateral cochlear implantation in such patient can be a very effective tool for rehabilitation. Copyright © 2011 Elsevier Inc. All rights reserved.

  10. Outcomes of cochlear implantation in deaf children of deaf parents: comparative study.

    Science.gov (United States)

    Hassanzadeh, S

    2012-10-01

    This retrospective study compared the cochlear implantation outcomes of first- and second-generation deaf children. The study group consisted of seven deaf, cochlear-implanted children with deaf parents. An equal number of deaf children with normal-hearing parents were selected by matched sampling as a reference group. Participants were matched based on onset and severity of deafness, duration of deafness, age at cochlear implantation, duration of cochlear implantation, gender, and cochlear implant model. We used the Persian Auditory Perception Test for the Hearing Impaired, the Speech Intelligibility Rating scale, and the Sentence Imitation Test, in order to measure participants' speech perception, speech production and language development, respectively. Both groups of children showed auditory and speech development. However, the second-generation deaf children (i.e. deaf children of deaf parents) exceeded the cochlear implantation performance of the deaf children with hearing parents. This study confirms that second-generation deaf children exceed deaf children of hearing parents in terms of cochlear implantation performance. Encouraging deaf children to communicate in sign language from a very early age, before cochlear implantation, appears to improve their ability to learn spoken language after cochlear implantation.

  11. Patient-specific estimation of detailed cochlear shape from clinical CT images

    DEFF Research Database (Denmark)

    Kjer, H Martin; Fagertun, Jens; Wimmer, Wilhelm

    2018-01-01

    of the detailed patient-specific cochlear shape from CT images. From a collection of temporal bone [Formula: see text]CT images, we build a cochlear statistical deformation model (SDM), which is a description of how a human cochlea deforms to represent the observed anatomical variability. The model is used...... for regularization of a non-rigid image registration procedure between a patient CT scan and a [Formula: see text]CT image, allowing us to estimate the detailed patient-specific cochlear shape. We test the accuracy and precision of the predicted cochlear shape using both [Formula: see text]CT and CT images...

  12. Arthritis: Conventional and Advanced Radiological Imaging

    Directory of Open Access Journals (Sweden)

    Adviye Ergun

    2014-06-01

    Full Text Available Arthritides are acute or chronic inflammation of one or more joints. The most common types of arthritis are osteoarthritis and rheumatoid arthritis, but there are more than 100 different forms. Right and early diagnosis is extremely important for the prevention of eventual structural and functional disability of the affected joint. Imaging findings, especially those of advanced level imaging, play a major role in diagnosis and monitor the progression of arthritis or its response to therapy. The objective of the review is to discuss the findings of conventional and advanced radiological imaging of most common arthritides and to present a simplified approach for their radiological evaluation.

  13. Digital image information systems in radiology

    International Nuclear Information System (INIS)

    Greinacher, C.F.C.; Luetke, B.; Seufert, G.

    1987-01-01

    About 25% of all patient examinations are performed digitally in a today's radiological department. A computerized system is described that supports generation, transport, interpretation and archiving of digital radiological images (Picture Archiving and Communication System PACS). The technical features concerning image communication via local area networks, image storage on magnetic and optical media and digital workstations for image display and manipulation are described. A structured system architecture is introduced. It allows flexible adaption to individual organizations and minimizes the requirements of the communication network. (orig.) [de

  14. Ewing sarcoma of the foot. Radiological findings

    International Nuclear Information System (INIS)

    Albisinni, U.; Capanna, R.; Nigrisoli, M.

    1987-01-01

    Ewing's Sarcoma (ES) is the most frequent malignant bone tumor of the foot. The radiological picture is characterized, in 14 patients, by a pure osteolytic lesion (9 cases) or by a mixed one (5 cases); the interruption of the cortical bone and swelling of the soft tissues were always present; the periostal reaction was occasional. The radiological aspects cannot be considered typical of the ES and it is suggested that biopsies should always be performed in the presence of structural alteration of the bone

  15. Music perception and appraisal: cochlear implant users and simulated cochlear implant listening.

    Science.gov (United States)

    Wright, Rose; Uchanski, Rosalie M

    2012-05-01

    The inability to hear music well may contribute to decreased quality of life for cochlear implant (CI) users. Researchers have reported recently on the generally poor ability of CI users to perceive music, and a few researchers have reported on the enjoyment of music by CI users. However, the relation between music perception skills and music enjoyment is much less explored. Only one study has attempted to predict CI users' enjoyment and perception of music from the users' demographic variables and other perceptual skills (Gfeller et al, 2008). Gfeller's results yielded different predictive relationships for music perception and music enjoyment, and the relationships were weak, at best. The first goal of this study is to clarify the nature and relationship between music perception skills and musical enjoyment for CI users, by employing a battery of music tests. The second goal is to determine whether normal hearing (NH) subjects, listening with a CI simulation, can be used as a model to represent actual CI users for either music enjoyment ratings or music perception tasks. A prospective, cross-sectional observational study. Original music stimuli (unprocessed) were presented to CI users, and music stimuli processed with CI-simulation software were presented to 20 NH listeners (CIsim). As a control, original music stimuli were also presented to five other NH listeners. All listeners appraised 24 musical excerpts, performed music perception tests, and filled out a musical background questionnaire. Music perception tests were the Appreciation of Music in Cochlear Implantees (AMICI), Montreal Battery for Evaluation of Amusia (MBEA), Melodic Contour Identification (MCI), and University of Washington Clinical Assessment of Music Perception (UW-CAMP). Twenty-five NH adults (22-56 yr old), recruited from the local and research communities, participated in the study. Ten adult CI users (46-80 yr old), recruited from the patient population of the local adult cochlear implant

  16. Gastrointestinal and hepatobiliary radiology

    International Nuclear Information System (INIS)

    Graham, R.N.J.; Perriss, R.W.; Scarsbrook, A.F.

    2006-01-01

    This is the fifth in the series of short reviews of internet-based radiological learning resources and will focus on gastrointestinal (GI) and hepatobiliary radiology. Below are details of a few of the higher quality resources currently available. Most of the sites cater for medical students and trainee or non-specialist radiologists, but may be also be of interest to specialists, especially for use in teaching. Hyperlinks are available in the electronic version of this article and were all active at the time of going to press (May 2006)

  17. Genitourinary and breast radiology

    International Nuclear Information System (INIS)

    Perriss, R.W.; Graham, R.N.J.; Scarsbrook, A.F.

    2006-01-01

    This is the sixth in a series of short reviews of internet-based radiological learning resources and will focus on genitourinary (GU) and breast radiology. Below are details of a few of the higher quality resources currently available. Most of the sites cater for medical students and trainee or non-specialist radiologists, but may be also be of interest to specialists, especially for use in teaching. Hyperlinks are available in the electronic version of this article and were all active at the time of going to press (July 2006)

  18. Practical interventional radiology

    International Nuclear Information System (INIS)

    Lammer, J.; Schreyer, H.

    1991-01-01

    The book is intended as a practical guide and manual for interventional radiology applications. Main emphasis is placed on the performance of the various techniques, with explanations of the various steps to be taken, illustrated by drawings or pictures. Indications, contra-indications and clinical achievements are given in brief. There is one chapter each for the following techniques: angioplasty - intra-arterial fibrinolysis - vascular stents - neuroembolisation - embolisation of other vessels - biliary interventions - abscess drainage - nephrostomy and ureteral manipulations -percutaneous fine-needle biopsy - vena cava filters - interventional radiology in infants. (orig.)

  19. Dosimetry in Radiology

    International Nuclear Information System (INIS)

    Andisco, D.; Blanco, S.; Buzzi, A.E

    2014-01-01

    The steady growth in the use of ionizing radiation in diagnostic imaging requires to maintain a proper management of patient’s dose. Dosimetry in Radiology is a difficult topic to address, but vital for proper estimation of the dose the patient is receiving. The awareness that every day is perceived in our country on these issues is the appropriate response to this problem. This article describes the main dosimetric units used and easily exemplifies doses in radiology through internationally known reference values. (authors) [es

  20. Westinghouse radiological containment guide

    International Nuclear Information System (INIS)

    Aitken, S.B.; Brown, R.L.; Cantrell, J.R.; Wilcox, D.P.

    1994-03-01

    This document provides uniform guidance for Westinghouse contractors on the implementation of radiological containments. This document reflects standard industry practices and is provided as a guide. The guidance presented herein is consistent with the requirements of the DOE Radiological Control Manual (DOE N 5480.6). This guidance should further serve to enable and encourage the use of containments for contamination control and to accomplish the following: Minimize personnel contamination; Prevent the spread of contamination; Minimize the required use of protective clothing and personal protective equipment; Minimize the generation of waste

  1. Synopsis of radiologic anatomy

    International Nuclear Information System (INIS)

    Meschan, I.

    1987-01-01

    The book is a compact version of earlier publications that appeared in 1975 as a one- and a two-volume issue under the title 'Atlas of Radiologic Anatomy'. A chapter on computed tomography has been added as this novel technique requires a new approach to radiologic anatomy. The radiologist will find all the information on the anatomic conditions he needs for analysing radiographs and CT pictures. More than 600 radiographs and CT pictures are given that illustrate typical and rare findings. The book also is useful as a source of reference for making good radiographs and evaluating the quality of radiographs or CT pictures. With 1413 figs., 18 tabs [de

  2. Radiological worker training

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-10-01

    This Handbook describes an implementation process for core training as recommended in Implementation Guide G441.12, Radiation Safety Training, and as outlined in the DOE Radiological Control Standard (RCS). The Handbook is meant to assist those individuals within the Department of Energy, Managing and Operating contractors, and Managing and Integrating contractors identified as having responsibility for implementing core training recommended by the RCS. This training is intended for radiological workers to assist in meeting their job-specific training requirements of 10 CFR 835. While this Handbook addresses many requirements of 10 CFR 835 Subpart J, it must be supplemented with facility-specific information to achieve full compliance.

  3. Radiological sciences dictionary

    CERN Document Server

    Dowsett, David

    2009-01-01

    The Radiological Sciences Dictionary is a rapid reference guide for all hospital staff employed in diagnostic imaging, providing definitions of over 3000 keywords as applied to the technology of diagnostic radiology.Written in a concise and easy to digest form, the dictionary covers a wide variety of subject matter, including:· radiation legislation and measurement · computing and digital imaging terminology· nuclear medicine radionuclides and radiopharmaceuticals· radiographic contrast agents (x-ray, MRI and ultrasound)· definitions used in ultrasound and MRI technology· statistical exp

  4. Westinghouse radiological containment guide

    Energy Technology Data Exchange (ETDEWEB)

    Aitken, S.B. [Idaho National Engineering Lab., Idaho Falls, ID (United States); Brown, R.L. [Westinghouse Hanford Co., Richland, WA (United States); Cantrell, J.R. [Westinghouse Savannah River Co., Aiken, SC (United States); Wilcox, D.P. [West Valley Nuclear Services Co., Inc., West Valley, NY (United States)

    1994-03-01

    This document provides uniform guidance for Westinghouse contractors on the implementation of radiological containments. This document reflects standard industry practices and is provided as a guide. The guidance presented herein is consistent with the requirements of the DOE Radiological Control Manual (DOE N 5480.6). This guidance should further serve to enable and encourage the use of containments for contamination control and to accomplish the following: Minimize personnel contamination; Prevent the spread of contamination; Minimize the required use of protective clothing and personal protective equipment; Minimize the generation of waste.

  5. Radiological worker training

    International Nuclear Information System (INIS)

    1998-10-01

    This Handbook describes an implementation process for core training as recommended in Implementation Guide G441.12, Radiation Safety Training, and as outlined in the DOE Radiological Control Standard (RCS). The Handbook is meant to assist those individuals within the Department of Energy, Managing and Operating contractors, and Managing and Integrating contractors identified as having responsibility for implementing core training recommended by the RCS. This training is intended for radiological workers to assist in meeting their job-specific training requirements of 10 CFR 835. While this Handbook addresses many requirements of 10 CFR 835 Subpart J, it must be supplemented with facility-specific information to achieve full compliance

  6. Radiology of thoracic trauma

    International Nuclear Information System (INIS)

    Stark, P.

    1987-01-01

    This course provides an overview of the radiologic manifestations of trauma to the chest. The basic mechanisms of injury are discussed. The effect of trauma on the chest wall, the lung parenchyma, and the pleural space is described. Rib fractures, sternal fractures, lung contusion, lung hematoma, lung laceration, post-traumatic atelectasis, hemothorax, chylothorax, pneumothorax, and adult respiratory distress syndrome are discussed and illustrated. Injuries to the tracheobronchial tree, the aorta and brachiocephalic vessels, the esophagus, the diaphragm, and the heart are also presented. The purpose of the lecture is to familiarize the audience with common and unusual radiologic presentations of traumatic injury to the thorax

  7. Anesthesia for interventional radiology

    International Nuclear Information System (INIS)

    van Sonnenberg, E.; Casola, G.; Varney, R.R.; D'Agostino, H.B.; Zornow, M.; Mazzie, W.

    1989-01-01

    We recognized that the complexity and surgical nature of many interventional radiology procedures dictate essential radiologic involvement into traditional anesthesiologic areas. They reviewed our experience with a variety of interventional procedures to document complications and problems related to anesthetic use (or misuse) and compile recommendations for rational monitoring and control for these procedures. In particular, the authors have studied complications of drug therapies and the treatment of these complications; use of complex anesthesia procedures (e.g., epidural anesthesia, succinylcholine blockage); reasons for choice of drugs (e.g., fentanyl vs meperidine vs morphine); and medico-legal aspects of radiologist performing traditional anesthesiology-type procedures

  8. Sampling on radiological protection training in diagnostic radiology

    International Nuclear Information System (INIS)

    Gaona, E.

    2001-01-01

    Radiological security aspects were evaluated in radiology departments from Mexico City. The study was carried out in two stages, the first one evaluated 40 departments just before the implementation of the new Official Mexican Standards related to Radiological Security and Quality Control in Radiology; in the second stage 33 departments were evaluated 2 years after those standards were implanted, showing a favorable impact of the training programs for the type of answers obtained [es

  9. Introduction of radiological protection; Pengenalan kepada perlindungan radiologi

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1988-12-31

    The chapter briefly discussed the following subjects: basic principles of radiological protection , dose limit which was suggested, stochastic and nonstochastic effects, equivalent dose and alternative of it`s calculation, limit for the publics, ICRP (International Commission for Radiological Protection) recommendations, and the principles of radiological protection. Dangerous radiation sources also briefly summarized i.e. x-ray generators, reactor nucleus.

  10. Radiological monitoring of food in Cuba

    International Nuclear Information System (INIS)

    Jerez V, S.F.

    1996-01-01

    The appearing of the problem for protecting the environment from radioactive contamination is not an accidental matter. The introduction into the earth crust of radioactive material coming from nuclear weapons, accidents, wastes, etc, has caused, as a consequence, the contamination of the biosphere. The extensive trade of food in our country has made necessary the establishment of radiological monitoring in food, which was organized by the Department of Public Health. The structure, functions, characteristics and aspects related to radiological monitoring of food in Cuba are shown in the present paper. The organization and resources for performing the monitoring program, both for normal conditions and for nuclear and/or radiological emergency cases, are detailed. (author). 12 refs., 2 figs

  11. Guidelines for a radiology department

    International Nuclear Information System (INIS)

    1981-05-01

    This manual presents guidelines for hospitals on a radiology quality assurance and dose measurement audit program and a system of planned actions that monitor and record the performance and effectiveness of the radiological service

  12. Radiological Approach to Forefoot Pain

    Directory of Open Access Journals (Sweden)

    Sai Chung Ho

    2015-06-01

    Full Text Available Forefoot pain is a common clinical complaint in orthopaedic practice. In this article, we discuss the anatomy of the forefoot, clinical and radiological approaches to forefoot pain, and common painful forefoot disorders and their associated radiological features.

  13. 324 Building Baseline Radiological Characterization

    Energy Technology Data Exchange (ETDEWEB)

    R.J. Reeder, J.C. Cooper

    2010-06-24

    This report documents the analysis of radiological data collected as part of the characterization study performed in 1998. The study was performed to create a baseline of the radiological conditions in the 324 Building.

  14. Radiological controls integrated into design

    Energy Technology Data Exchange (ETDEWEB)

    Kindred, G.W. [Cleveland Electric Illuminating Co., Perry, OH (United States)

    1995-03-01

    Radiological controls are required by law in the design of commercial nuclear power reactor facilities. These controls can be relatively minor or significant, relative to cost. To ensure that radiological controls are designed into a project, the health physicist (radiological engineer) must be involved from the beginning. This is especially true regarding keeping costs down. For every radiological engineer at a nuclear power plant there must be fifty engineers of other disciplines. The radiological engineer cannot be an expert on every discipline of engineering. However, he must be knowledgeable to the degree of how a design will impact the facility from a radiological perspective. This paper will address how to effectively perform radiological analyses with the goal of radiological controls integrated into the design package.

  15. Program of environmental radiological monitoring

    International Nuclear Information System (INIS)

    2005-11-01

    This Regulation refers to the requirement of the Regulation CNEN-NN.3.01, 'Basic Act of Radiological Protection', as expressed in the section 5.14, related to the Program of Environmental Radiological Monitoring (PMRA)

  16. Semitone frequency mapping to improve music representation for nucleus cochlear implants

    Directory of Open Access Journals (Sweden)

    Omran Sherif

    2011-01-01

    Full Text Available Abstract The frequency-to-channel mapping for Cochlear implant (CI signal processors was originally designed to optimize speech perception and generally does not preserve the harmonic structure of music sounds. An algorithm aimed at restoring the harmonic relationship of frequency components based on semitone mapping is presented in this article. Two semitone (Smt based mappings in different frequency ranges were investigated. The first, Smt-LF, covers a range from 130 to 1502 Hz which encompasses the fundamental frequency of most musical instruments. The second, Smt-MF, covers a range from 440 to 5040 Hz, allocating frequency bands of sounds close to their characteristic tonotopical sites according to Greenwood's function. Smt-LF, in contrast, transposes the input frequencies onto locations with higher characteristic frequencies. A sequence of 36 synthetic complex tones (C3 to B5, each consisting of a fundamental and 4 harmonic overtones, was processed using the standard (Std, Smt-LF and Smt-MF mappings. The analysis of output signals showed that the harmonic structure between overtones of all complex tones was preserved using Smt mapping. Semitone mapping preserves the harmonic structure and may in turn improve music representation for Nucleus cochlear implants. The proposed semitone mappings incorporate the use of virtual channels to allow frequencies spanning three and a half octaves to be mapped to 43 stimulation channels. A pitch difference limen test was done with normal hearing subjects discriminating pairs of pure tones with different semitone intervals which were processed by a vocoder type simulator of CI sound processing. The results showed better performance with wider semitone intervals. However, no significant difference was found between 22 and 43 channels maps.

  17. Reversing the polarity of a cochlear implant magnet after magnetic resonance imaging.

    Science.gov (United States)

    Jeon, Ju Hyun; Bae, Mi Ran; Chang, Jae Won; Choi, Jae Young

    2012-08-01

    The number of patients with cochlear implant (CI) has been rapidly increasing in recent years, and these patients show a growing need of examination by magnetic resonance imaging (MRI). However, the use of MRI on patients with CI is restricted by the internal magnet of the CI. Many studies have investigated the safety of performing 1.5T MRI on patients with CI, which is now being practiced in a clinical setting. We experienced a case in which the polarity of the cochlear implant magnet was reversed after the patient was examined using 1.5T MRI. The external device was attached to the internal device oppositely. We could not find displacement of the internal device, magnet, or electrode upon radiological evaluation. We came up with two possible mechanisms by which the polarity of the magnet reversed. The first possibility was that the magnetic field of MRI reversed the polarity of the magnet. The second was that the internal magnet was physically realigned while interacting with the MRI. We believe the second hypothesis to be more reliable. A removable magnet and a loose magnet boundary of a CI device may have allowed for physical reorientation of the internal magnet. Therefore, in order to avoid these complications, first, the internal magnet must not be aligned anti-parallel with the magnetic polarity of MRI. In the Siemens MRI, the vector of the magnetic field is downward, so implant site should be placed in facing upwards to minimize demagnetization. In the GE Medical Systems MRI, the vector of the magnetic field is upward, so the implant site should be placed facing downwards. Second, wearing of a commercial mold which is fixed to the internal device before performing MRI can be helpful. In addition, any removable internal magnets in a CI device should be removed before MRI, especially in the trunk. However, to ultimately solve this problem, the pocket of the internal magnet should be redesigned for safety. Copyright © 2011. Published by Elsevier Ireland Ltd.

  18. SA Journal of Radiology

    African Journals Online (AJOL)

    Radiology examination as a diagnostic aid in presentations with wide differential diagnoses: Case report of new Hodgkin's lymphoma on a background of poorly controlled HIV · EMAIL FREE FULL TEXT EMAIL FREE FULL TEXT · DOWNLOAD FULL TEXT DOWNLOAD FULL TEXT. Rachel Hubbard, Jalpa Kotecha, Thomas ...

  19. Classification of radiological procedures

    International Nuclear Information System (INIS)

    1989-01-01

    A classification for departments in Danish hospitals which use radiological procedures. The classification codes consist of 4 digits, where the first 2 are the codes for the main groups. The first digit represents the procedure's topographical object and the second the techniques. The last 2 digits describe individual procedures. (CLS)

  20. Radiology of the pancreas

    International Nuclear Information System (INIS)

    Baert, A.L.; Delorme, G.

    1994-01-01

    This book, written by internationally recognized experts, fully illustrates the diagnosis of both common and rarer diseases of the pancreas, the latest technical developments in relevant imaging modalities are thoroughly discussed and appraised with respect to the pancreas. The book will appeal to both clinicians and researchers in radiology and oncology. (orig.)

  1. ERC Radiological Glovebag Program

    International Nuclear Information System (INIS)

    Nellesen, A.L.

    1997-07-01

    This document establishes the requirements and responsibilities for the standardized methods for installation, use, and dismantlement of glovebags within the Hanford Site Environmental Contractor Radiological Glovebag Program. This document addresses the following topics: Containment selection and fabrication, Glovebag fabrication, Containment installation and inspection, General glovebag containment work practices, Emergency situations, and Containment removal

  2. German radiological congress 1983

    International Nuclear Information System (INIS)

    Haubitz, B.; Stender, H.S.

    1983-01-01

    The publication contains the abstracts of the 261 papers read at the meeting and the 82 further papers announced, and 37 brief descriptions of the contributions to the scientific exhibition. The papers were on the subjects of radiology, nuclear medicine and to a certain extent, also radiobiology. (MG) [de

  3. Medical radiology terminology

    International Nuclear Information System (INIS)

    1986-01-01

    Standardization achievements in the field of radiology induced the IEC to compile the terminology used in its safety and application standards and present it in publication 788 (1984 issue), entitled 'Medical radiology terminology'. The objective pursued is to foster the use of standard terminology in the radiology standards. The value of publication 788 lies in the fact that it presents definitions of terms used in the French and English versions of IEC standards in the field of radiology, and thus facilitates adequate translation of these terms into other languages. In the glossary in hand, German-language definitions have been adopted from the DIN standards in cases where the French or English versions of definitions are identical with the German wording or meaning. The numbers of DIN standards or sections are then given without brackets, ahead of the text of the definition. In cases where correspondance of the various texts is not so good, or reference should be made to a term in a DIN standard, the numbers are given in brackets. (orig./HP) [de

  4. Collaborative Radiological Response Planning

    Science.gov (United States)

    2013-12-01

    DOE and EPA national laboratories .55 Additionally, the GAO conducted a survey of emergency management officials in cities, states and federal...for Biosecurity of UPMC, (2012). After fukushima: Managing the consequences of a radiological release. Retrieved from : http://issuu.com

  5. Radiological protective screen

    International Nuclear Information System (INIS)

    Flaugnatti, R.B.

    1976-01-01

    A radiological screen for placing on a patient's skin is discussed, comprising a flat jacket containing a fine particulate filler and a settable resin binder, the fine particulate filler being of a material which absorbs medical radiation, and the jacket including a window to transmit such radiation through the flat jacket. 16 claims, 4 drawing figures

  6. Radiology of spinal curvature

    International Nuclear Information System (INIS)

    De Smet, A.A.

    1985-01-01

    This book offers the only comprehensive, concise summary of both the clinical and radiologic features of thoracic and lumbar spine deformity. Emphasis is placed on idiopathic scoliosis, which represents 85% of all patients with scoliosis, but less common areas of secondary scoliosis, kyphosis and lordosis are also covered

  7. Radiological safety by design

    International Nuclear Information System (INIS)

    Gundaker, W.E.

    1977-01-01

    Under the Radiation Control for Health and Safety Act enacted by the U.S. Congress in 1968, the Food and Drug Administration's Bureau of Radiological Health may prescribe performance standards for products that emit radiation. A description is given of the development of these standards and outlines the administrative procedures by which they are enforced. (author)

  8. Radiology in emergency medicine

    International Nuclear Information System (INIS)

    Levy, R.; Barsan, W.G.

    1986-01-01

    This book gives a discussion of radiologic modalities currently being used in emergency situations. Radiographs, echocardiographs, radionuclide scans and CT scans are systematically analyzed and evaluated to provide a step-by-step diagnostic process for emergency physicians to follow when a radiologist is not present

  9. Cardiovascular and interventional radiology

    International Nuclear Information System (INIS)

    White, R.I. Jr.

    1985-01-01

    A symposium of eight short but complete papers giving an overview of interventional radiology is presented. Organized by Dr. William Casarella, this symposium is certainly the most current review of the subject available. This year's cardiovascular section is again heavily weighted toward interventional radiology. Abrams and Doubilet's article on the underutilization of angioplasty is important because it describes the cost effectiveness of this method. Most health planners, right or wrong, have complained about overutilization of diagnostic radiology procedures. In general, the opposite is true for interventional procedures - they are underutilized. If the authors draw the attention of their hospital administrators to these approaches and also produce the data on long-term follow-up for our medical colleagues, interventional radiology may realize its full potential. Articles on cardiac magnetic resonance imaging are beginning to appear and this technique seems to have great potential. An important article, which is the first prospective study comparing lung scintigraphy and pulmonary angiography in the diagnosis of pulmonary embolism, supports the increased use of pulmonary angiography. Finally, an article on complications of percutaneous biliary drainage provokes some discussion of its value for routine preoperative use

  10. The radiological technologist

    International Nuclear Information System (INIS)

    Bundy, A.L.

    1988-01-01

    Radiologists rely upon the talents of the technologists with whom they work. Indeed, a good technologist will only enhance the radiologist's performance. Radiological technologists no longer solely take radiographs, but are involved in many more detailed areas of imaging, such as computered tomography, magnetic resonance imaging, nuclear radiology, ultrasound, angiography, and special procedures. They are also required to make decisions that affect the radiological examination. Besides the degree in radiological technology (RT), advanced degrees in nuclear medicine technology (NMT) and diagnostic medical sonography (RDMS) are attainable. The liability of the technologist is not the same as the radiologist involved, but the liability is potentially real and governed by a subdivision of jurisprudence known as agency law. Since plaintiffs and attorneys are constantly searching for new frontiers of medical liability, it is wise for the radiologist and technologist to be aware of the legalities governing their working relationship and to behave accordingly. The legal principles that apply to this working relationship are discussed in this chapter, followed by a presentation of some relevant and interesting cases that have been litigated

  11. Automatic Model Generation Framework for Computational Simulation of Cochlear Implantation

    DEFF Research Database (Denmark)

    Mangado Lopez, Nerea; Ceresa, Mario; Duchateau, Nicolas

    2016-01-01

    . To address such a challenge, we propose an automatic framework for the generation of patient-specific meshes for finite element modeling of the implanted cochlea. First, a statistical shape model is constructed from high-resolution anatomical μCT images. Then, by fitting the statistical model to a patient......'s CT image, an accurate model of the patient-specific cochlea anatomy is obtained. An algorithm based on the parallel transport frame is employed to perform the virtual insertion of the cochlear implant. Our automatic framework also incorporates the surrounding bone and nerve fibers and assigns......Recent developments in computational modeling of cochlear implantation are promising to study in silico the performance of the implant before surgery. However, creating a complete computational model of the patient's anatomy while including an external device geometry remains challenging...

  12. Evidence of echoic memory with a multichannel cochlear prosthesis.

    Science.gov (United States)

    Jerger, S; Watkins, M J

    1988-10-01

    Short-term memory was examined in a subject with a multichannel cochlear prosthesis. Serial recall for lists of digits revealed what are widely regarded as the principal hallmarks of echoic memory, namely the recency effect and the suffix effect. Thus, probability of recall increased for the last one or two digits, except when a nominally irrelevant but spoken item was appended to the to-be-remembered list. It appears, therefore, that a multichannel cochlear implant can give rise to not only the perception of, but also an echoic memory for, speech. As with normal subjects, the suffix effect did not occur with a nonspeech suffix, implying that the echoic memory from the prosthesis shows normal sensitivity to the distinction between speech and nonspeech.

  13. Piezoelectric materials mimic the function of the cochlear sensory epithelium.

    Science.gov (United States)

    Inaoka, Takatoshi; Shintaku, Hirofumi; Nakagawa, Takayuki; Kawano, Satoyuki; Ogita, Hideaki; Sakamoto, Tatsunori; Hamanishi, Shinji; Wada, Hiroshi; Ito, Juichi

    2011-11-08

    Cochlear hair cells convert sound vibration into electrical potential, and loss of these cells diminishes auditory function. In response to mechanical stimuli, piezoelectric materials generate electricity, suggesting that they could be used in place of hair cells to create an artificial cochlear epithelium. Here, we report that a piezoelectric membrane generated electrical potentials in response to sound stimuli that were able to induce auditory brainstem responses in deafened guinea pigs, indicating its capacity to mimic basilar membrane function. In addition, sound stimuli were transmitted through the external auditory canal to a piezoelectric membrane implanted in the cochlea, inducing it to vibrate. The application of sound to the middle ear ossicle induced voltage output from the implanted piezoelectric membrane. These findings establish the fundamental principles for the development of hearing devices using piezoelectric materials, although there are many problems to be overcome before practical application.

  14. [Cochlear implant in children: rational, indications and cost/efficacy].

    Science.gov (United States)

    Martini, A; Bovo, R; Trevisi, P; Forli, F; Berrettini, S

    2013-06-01

    A cochlear implant (CI) is a partially implanted electronic device that can help to provide a sense of sound and support speech to severely to profoundly hearing impaired patients. It is constituted by an external portion, that usually sits behind the ear and an internal portion surgically placed under the skin. The external components include a microphone connected to a speech processor that selects and arranges sounds pucked up by the microphone. This is connected to a transmitter coil, worn on the side of the head, which transmits data to an internal receiver coil placed under the skin. The received data are delivered to an array of electrodes that are surgically implanted within the cochlea. The primary neural targets of the electrodes are the spiral ganglion cells which innervate fibers of the auditory nerve. When the electrodes are activated by the signal, they send a current along the auditory nerve and auditory pathways to the auditory cortex. Children and adults who are profoundly or severely hearing impaired can be fitted with cochlear implants. According to the Food and Drug Administration, approximately 188,000 people worldwide have received implants. In Italy it is extimated that there are about 6-7000 implanted patients, with an average of 700 CI surgeries per year. Cochlear implantation, followed by intensive postimplantation speech therapy, can help young children to acquire speech, language, and social skills. Early implantation provides exposure to sounds that can be helpful during the critical period when children learn speech and language skills. In 2000, the Food and Drug Administration lowered the age of eligibility to 12 months for one type of CI. With regard to the results after cochlear implantation in relation to early implantation, better linguistic results are reported in children implanted before 12 months of life, even if no sufficient data exist regarding the relation between this advantage and the duration of implant use and how long

  15. Emergency radiological monitoring and analysis United States Federal Radiological Monitoring and Assessment Center

    International Nuclear Information System (INIS)

    Thome, D.J.

    1994-01-01

    The United States Federal Radiological Emergency Response Plan (FRERP) provides the framework for integrating the various Federal agencies responding to a major radiological emergency. Following a major radiological incident the FRERP authorizes the creation of the Federal Radiological Monitoring and Assessment Center (FRMAC). The FRMAC is established to coordinate all Federal agencies involved in the monitoring and assessment of the off-site radiological conditions in support of the impacted states and the Lead Federal Agency (LFA). Within the FRMAC, the Monitoring and Analysis Division is responsible for coordinating all FRMAC assets involved in conducting a comprehensive program of environmental monitoring, sampling, radioanalysis and quality assurance. This program includes: (1) Aerial Radiological Monitoring - Fixed Wing and Helicopter, (2) Field Monitoring and Sampling, (3) Radioanalysis - Mobile and Fixed Laboratories, (4) Radiation Detection Instrumentation - Calibration and Maintenance, (5) Environmental Dosimetry, and (6) An integrated program of Quality Assurance. To assure consistency, completeness and the quality of the data produced, a methodology and procedures handbook is being developed. This paper discusses the structure, assets and operations of FRMAC monitoring and analysis and the content and preparation of this handbook

  16. Radiologic technology educators and andragogy.

    Science.gov (United States)

    Galbraith, M W; Simon-Galbraith, J A

    1984-01-01

    Radiologic technology educators are in constant contact with adult learners. However, the theoretical framework that radiologic educators use to guide their instruction may not be appropriate for adults. This article examines the assumptions of the standard instructional theory and the most modern approach to adult education-- andragogy . It also shows how these assumptions affect the adult learner in a radiologic education setting.

  17. Recent trend of diagnostic radiology

    International Nuclear Information System (INIS)

    Kim, S.Y.; Kim, H.K.

    1979-01-01

    Present status and recent trend of diagnostic radiology have been reviewed. The interrelationships and Characteristics of various fields of radiology such as computed tomography, X-ray radiology, and nuclear medicine were discussed. The mevit of computed tomography and the promising use of short lived, accelerator produced radionuclides, and radiotherapy in nuclear medicine were emphasized. (author)

  18. [Hierarchical structure of authors collaboration. An analysis of papers on imaging diagnosis published by hospital radiology departments in Comunidad Valenciana (1994-2001)].

    Science.gov (United States)

    Miguel-Dasit, A; Martí-Bonmatí, L; Sanfeliu, P; Aleixandre, R; Valderrama, J C

    2005-06-01

    Analyze the different contribution of hierarchical categories in the papers published by radiologists of hospitals belonging to Comunidad Valenciana along the period 1994-2001, as well as their distribution in the different journals. For the recovery of the papers sample we have designed specific search profiles for EMI and Medline databases. Hierarchical category of the authors was identified through personal interviews. We have analyzed 417 works, with 1,321 authors distributed in the following form: chief of service, 8.8%; chief of section, 12.4%; assistant physician, 50.7%, and resident, 28%. Hierarchical groupings with participation of residents were more consistent for publishing papers along all the study period (1994-2001). Higher percentage of papers (21%) corresponded to grouping. Radiología was the most productive journal (42% papers). All results were statistically significant (p Comunidad Valenciana hospitals showed an active participation in research papers published along the period 1994-2001, in collaboration with the rest of the hierarchical categories, basically with the assistant physician. Assistant physicians contributed most of papers. Chief of section and chief of department contributed fifth of papers.

  19. Ethical problems in radiology: radiological consumerism.

    Science.gov (United States)

    Magnavita, N; Bergamaschi, A

    2009-10-01

    One of the causes of the increasing request for radiological examinations occurring in all economically developed countries is the active role played by the patient-consumer. Consumerism places the radiologist in an ethical dilemma, between the principle of autonomy on the one hand and the ethical principles of beneficence, nonmaleficence and justice on the other. The choice made by radiologists in moral dilemmas is inspired by an adherence to moral principles, which in Italy and elsewhere refer to the Judaeo-Christian tradition or to neo-Darwinian relativism. Whatever the choice, the radiologist is bound to adhere to that choice and to provide the patient with all the relevant information regarding his or her state of health.

  20. Radiological Worker Training: Radiological Worker 2 study guides

    International Nuclear Information System (INIS)

    1992-10-01

    Upon completion of this training course, the participant will have the knowledge to work safely in areas controlled for radiological purposes using proper radiological practices. Radiological Worker H Training, for the worker whose job assignment involves entry into Radiological Buffer Areas and all types of Radiation Contamination and Airborne Radioactivity Areas. This course is designed to prepare the worker to work safely in and around radiological areas and present methods to use to ensure individual radiation exposure is maintained As Low As Reasonably Achievable

  1. Computer technique for correction of nonhomogeneous distribution in radiologic images

    International Nuclear Information System (INIS)

    Florian, Rogerio V.; Frere, Annie F.; Schiable, Homero; Marques, Paulo M.A.; Marques, Marcio A.

    1996-01-01

    An image processing technique to provide a 'Heel' effect compensation on medical images is presented. It is reported that the technique can improve the structures detection due to background homogeneity and can be used for any radiologic system

  2. National inquiry system of radiological events: a viable proposal

    International Nuclear Information System (INIS)

    Xavier, Ana Maria; Cavalcante, Vera Lucia.

    1996-01-01

    The SINAER- National Inquiry System of Radiological Events is a supportive structure devised to deal with the request of help or complaints that involve sources of ionizing radiations in the national territory

  3. Complications in cochlear implantation at the Clinical Center of Vojvodina

    Directory of Open Access Journals (Sweden)

    Dankuc Dragan

    2015-01-01

    Full Text Available Introduction. The first modern cochlear implantation in Serbia was performed on November 26, 2002 at the Center for Cochlear Implantation of the Clinic for Ear, Nose and Throat Diseases, Clinical Center of Vojvodina. Objective. The aim of the paper is the analysis of intraoperative and postoperative complications. Major complications include those resulting in the necessity for revision surgery, explantation, reimplantation, severe disease or even lethal outcomes. Minor complications resolve spontaneously or can be managed by conservative therapy and do not require any prolonged hospitalization of the patient. Methods. In the 2002-2013 period, 99 patients underwent surgical procedures and 100 cochlear implants were placed. Both intraoperative and postoperative complications were analyzed in the investigated patient population. Results. The analysis encompassed 99 patients, the youngest and the oldest ones being one year old and 61 years old, respectively. The complications were noticed in 11 patients, i.e. in 10.5% of 105 surgical procedures. The majority of procedures (89.5% were not accompanied by any post-surgical complications. Unsuccessful implantation in a single-step procedure (4.04% and transient facial nerve paralysis can be considered most frequent among our patients, whereas cochlear ossification (1.01% and transient ataxia (2.02% occurred rarely. Stimulation of the facial nerve (1.01%, intraoperative perilymph liquid gusher (1.01%, device failure and late infections (1.01% were recorded extremely rarely. Conclusion. Complications such as electrode extrusion, skin necrosis over the implant or meningitis, which is considered the most severe postoperative complication, have not been recorded at our Center since the very beginning. Absence of postoperative meningitis in patients treated at the Center can be attributed to timely pneumococcal vaccination of children.

  4. Noise-induced cochlear synaptopathy in rhesus monkeys (Macaca mulatta).

    Science.gov (United States)

    Valero, M D; Burton, J A; Hauser, S N; Hackett, T A; Ramachandran, R; Liberman, M C

    2017-09-01

    Cochlear synaptopathy can result from various insults, including acoustic trauma, aging, ototoxicity, or chronic conductive hearing loss. For example, moderate noise exposure in mice can destroy up to ∼50% of synapses between auditory nerve fibers (ANFs) and inner hair cells (IHCs) without affecting outer hair cells (OHCs) or thresholds, because the synaptopathy occurs first in high-threshold ANFs. However, the fiber loss likely impairs temporal processing and hearing-in-noise, a classic complaint of those with sensorineural hearing loss. Non-human primates appear to be less vulnerable to noise-induced hair-cell loss than rodents, but their susceptibility to synaptopathy has not been studied. Because establishing a non-human primate model may be important in the development of diagnostics and therapeutics, we examined cochlear innervation and the damaging effects of acoustic overexposure in young adult rhesus macaques. Anesthetized animals were exposed bilaterally to narrow-band noise centered at 2 kHz at various sound-pressure levels for 4 h. Cochlear function was assayed for up to 8 weeks following exposure via auditory brainstem responses (ABRs) and otoacoustic emissions (OAEs). A moderate loss of synaptic connections (mean of 12-27% in the basal half of the cochlea) followed temporary threshold shifts (TTS), despite minimal hair-cell loss. A dramatic loss of synapses (mean of 50-75% in the basal half of the cochlea) was seen on IHCs surviving noise exposures that produced permanent threshold shifts (PTS) and widespread hair-cell loss. Higher noise levels were required to produce PTS in macaques compared to rodents, suggesting that primates are less vulnerable to hair-cell loss. However, the phenomenon of noise-induced cochlear synaptopathy in primates is similar to that seen in rodents. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. Balance Performance of Deaf Children With and Without Cochlear Implants

    Directory of Open Access Journals (Sweden)

    Amir-Abbas Ebrahimi

    2016-12-01

    Full Text Available  The aim of this study was to compare the static and dynamic balance performance of deaf children with and without cochlear implants. This is a cross-sectional study of 145 school children, aged between 7 and 12 years comprising 85 children with congenital or early acquired bilateral profound sensorineural hearing loss (the hearing loss group and 60 normal hearing aged-matched control counterparts were assessed using the balance subtest of Bruininks-Oseretsky test of Motor Proficiency (BOTMP. The hearing loss group, 50 without cochlear implants (the non-implant group and 35 of them with unilateral cochlear implants (the implant group were recruited from schools for the deaf and normal hearing children (the control group randomly selected from two randomly selected elementary schools of Tehran city. The scores were analyzed using one-way ANOVA. The total score of deaf children especially the implant group were significantly lower than the control group P<0.001. The balance performance of the control group was better than the implant group in all of the items as well as the non-implant group except the fourth tested item (walking forward on a line (P<0.05. The balance score of the implant group was significantly lower than the non-implant group except for the third tested item (standing on the preferred leg on a balance beam with eyes closed. The findings suggested that deaf children, specifically those with cochlear implants are at risk for motor and balance deficits. Thus, vestibular and motor evaluations, as well as interventions to improve balance and motor skills, should be prioritized for this population.

  6. Cochlear implantation in children and adults in Switzerland

    OpenAIRE

    Brand, Yves; Senn, Pascal; Kompis, Martin; Dillier, Norbert; Allum, John H. J.

    2014-01-01

    The cochlear implant (CI) is one of the most successful neural prostheses developed to date. It offers artificial hearing to individuals with profound sensorineural hearing loss and with insufficient benefit from conventional hearing aids. The first implants available some 30 years ago provided a limited sensation of sound. The benefit for users of these early systems was mostly a facilitation of lip-reading based communication rather than an understanding of speech. Considerable progress has...

  7. Concept Formation Skills in Long-Term Cochlear Implant Users

    OpenAIRE

    Castellanos, Irina; Kronenberger, William G.; Beer, Jessica; Colson, Bethany G.; Henning, Shirley C.; Ditmars, Allison; Pisoni, David B.

    2014-01-01

    This study investigated if a period of auditory sensory deprivation followed by degraded auditory input and related language delays affects visual concept formation skills in long-term prelingually deaf cochlear implant (CI) users. We also examined if concept formation skills are mediated or moderated by other neurocognitive domains (i.e., language, working memory, and executive control). Relative to normally hearing (NH) peers, CI users displayed significantly poorer performance in several s...

  8. Lessons learned in radiology

    International Nuclear Information System (INIS)

    Goodenough, D.J.

    2001-01-01

    The paper reviews aspects of the history of radiology with the goal of identifying lessons learned, particularly in the area of radiological protection of the patient in diagnostic and interventional radiology, nuclear medicine and radiotherapy. It is pointed out that since the days of Roentgen there has been a need not only to control and quantify the amount of radiation reaching the patient but also to optimize the imaging process to offer the greatest diagnostic benefit within allowable levels of patient dose. To this end, in diagnostic radiology, one finds the development of better films, X rays tubes, grids, screens and processing techniques, while in fluoroscopy, one sees the increased luminance of calcium tungstate. In interventional radiology, one finds an improvement in catheterization techniques and contrast agents. In nuclear medicine, the development of tracer techniques into modern cameras and isotopes such as technetium can be followed. In radiotherapy, one sees the early superficial X rays and radium sources gradually replaced with radon seeds, supervoltage, 60 Co and today's linear accelerators. Along with the incredible advances in imaging and therapeutic technologies comes the growing realization of the potential danger of radiation and the need to protect the patient (as well as physicians, ancillary personnel and the general population) from unnecessary radiation. The important lesson learned is that we must walk a tightrope, balancing the benefits and risks of any technology utilizing radiation to produce the greatest benefits at the lowest acceptable risk. The alternative techniques using non-ionizing radiation will have to be considered as part of the general armamentarium for medical imaging whenever radiation consequences are unacceptable. (author)

  9. Free-form image registration of human cochlear μCT data using skeleton similarity as anatomical prior

    DEFF Research Database (Denmark)

    Kjer, Hans Martin; Fagertun, Jens; Vera, Sergio

    2016-01-01

    Better understanding of the anatomical variability of the human cochlear is important for the design and function of Cochlear Implants. Proper non-rigid alignment of high-resolution cochlear μCT data is a challenge for the typical cubic B-spline registration model. In this paper we study one way ...

  10. Cochlear function tests in estimation of speech dynamic range.

    Science.gov (United States)

    Han, Jung Ju; Park, So Young; Park, Shi Nae; Na, Mi Sun; Lee, Philip; Han, Jae Sang

    2016-10-01

    The loss of active cochlear mechanics causes elevated thresholds, loudness recruitment, and reduced frequency selectivity. The problems faced by hearing-impaired listeners are largely related with reduced dynamic range (DR). The aim of this study was to determine which index of the cochlear function tests correlates best with the DR to speech stimuli. Audiological data on 516 ears with pure tone average (PTA) of ≤55 dB and word recognition score of ≥70% were analyzed. PTA, speech recognition threshold (SRT), uncomfortable loudness (UCL), and distortion product otoacoustic emission (DPOAE) were explored as the indices of cochlear function. Audiometric configurations were classified. Correlation between each index and the DR was assessed and multiple regression analysis was done. PTA and SRT demonstrated strong negative correlations with the DR (r = -0.788 and -0.860, respectively), while DPOAE sum was moderately correlated (r = 0.587). UCLs remained quite constant for the total range of the DR. The regression equation was Y (DR) = 75.238 - 0.719 × SRT (R(2 )=( )0.721, p equation.

  11. Paediatric Cochlear Implantation in Patients with Waardenburg Syndrome.

    Science.gov (United States)

    van Nierop, Josephine W I; Snabel, Rebecca R; Langereis, Margreet; Pennings, Ronald J E; Admiraal, Ronald J C; Mylanus, Emmanuel A M; Kunst, Henricus P M

    2016-01-01

    To analyse the benefit of cochlear implantation in young deaf children with Waardenburg syndrome (WS) compared to a reference group of young deaf children without additional disabilities. A retrospective study was conducted on children with WS who underwent cochlear implantation at the age of 2 years or younger. The post-operative results for speech perception (phonetically balanced standard Dutch consonant-vocal-consonant word lists) and language comprehension (the Reynell Developmental Language Scales, RDLS), expressed as a language quotient (LQ), were compared between the WS group and the reference group by using multiple linear regression analysis. A total of 14 children were diagnosed with WS, and 6 of them had additional disabilities. The WS children were implanted at a mean age of 1.6 years and the 48 children of the reference group at a mean age of 1.3 years. The WS children had a mean phoneme score of 80% and a mean LQ of 0.74 at 3 years post-implantation, and these results were comparable to those of the reference group. Only the factor additional disabilities had a significant negative influence on auditory perception and language comprehension. Children with WS performed similarly to the reference group in the present study, and these outcomes are in line with the previous literature. Although good counselling about additional disabilities concomitant to the syndrome is relevant, cochlear implantation is a good rehabilitation method for children with WS. © 2016 S. Karger AG, Basel.

  12. Design of a new electrode array for cochlear implants

    International Nuclear Information System (INIS)

    Kha, H.; Chen, B.

    2010-01-01

    Full text: This study aims to design a new electrode array which can be precisely located beneath the basilar membrane within the cochlear scala tympani. This placement of the electrode array is beneficial for increasing the effectiveness of the electrical stimulation of the audi tory nerves and maximising the growth factors delivered into the cochlea for regenerating the progressively lost auditory neurons, thereby significantly improving performance of the cochlear implant systems. Methods The design process involved two steps. First, the biocom patible nitinol-based shape memory alloy, of which mechanical deformation can be controlled using electrical cUTents/fields act vated by body temperature, was selected. Second, five different designs of the electrode array with embedded nitinol actuators were studied (Table I). The finite element method was employed to predict final positions of these electrode arrays. Results The electrode array with three 6 mm actuators at 2-8, 8-J4 and 14-20 mm from the tip (Fig. I) was found to be located most closely to the basilar membrane, compared with those in the other four cases. Conclusions A new nitinol cochlear implant electrode array with three embedded nitinol actuators has been designed. This electrode array is expected to be located beneath the basilar membrane for maximising the delivery of growth factors. Future research will involve the manufacturing of a prototype of this electrode array for use in insertion experiments and neurotrophin release tests.

  13. Modeling of Auditory Neuron Response Thresholds with Cochlear Implants

    Directory of Open Access Journals (Sweden)

    Frederic Venail

    2015-01-01

    Full Text Available The quality of the prosthetic-neural interface is a critical point for cochlear implant efficiency. It depends not only on technical and anatomical factors such as electrode position into the cochlea (depth and scalar placement, electrode impedance, and distance between the electrode and the stimulated auditory neurons, but also on the number of functional auditory neurons. The efficiency of electrical stimulation can be assessed by the measurement of e-CAP in cochlear implant users. In the present study, we modeled the activation of auditory neurons in cochlear implant recipients (nucleus device. The electrical response, measured using auto-NRT (neural responses telemetry algorithm, has been analyzed using multivariate regression with cubic splines in order to take into account the variations of insertion depth of electrodes amongst subjects as well as the other technical and anatomical factors listed above. NRT thresholds depend on the electrode squared impedance (β = −0.11 ± 0.02, P<0.01, the scalar placement of the electrodes (β = −8.50 ± 1.97, P<0.01, and the depth of insertion calculated as the characteristic frequency of auditory neurons (CNF. Distribution of NRT residues according to CNF could provide a proxy of auditory neurons functioning in implanted cochleas.

  14. Ethical considerations in resource allocation in a cochlear implant program.

    Science.gov (United States)

    Westerberg, Brian D; Pijl, Sipke; McDonald, Michael

    2008-04-01

    To review processes of resource allocation and the ethical considerations relevant to the fair allocation of a limited number of cochlear implants to increasing numbers of potential recipients. Review of relevant considerations. Tertiary referral hospital. Editorial discussion of the ethical issues of resource allocation. Heterogeneity of audiometric thresholds, self-reported disability of hearing loss, age of the potential cochlear implant recipient, cost-effectiveness, access to resources, compliance with follow-up, social support available to the recipient, social consequences of hearing impairment, and other recipient-related factors. In a publicly funded health care system, there will always be a need for decision-making processes for allocation of finite fiscal resources. All candidates for cochlear implantation deserve fair consideration. However, they are a heterogeneous group in terms of needs and expected outcomes consisting of traditional and marginal candidates, with a wide range of benefit from acoustic amplification. We argue that implant programs should thoughtfully prioritize treatment on the basis of need and potential benefit. We reject queuing on the basis of "first-come, first-served" or on the basis of perceived social worth.

  15. Cochlear pathology following reimplantation of a multichannel scala tympani electrode array in the macaque.

    Science.gov (United States)

    Shepherd, R K; Clark, G M; Xu, S A; Pyman, B C

    1995-03-01

    result in more extensive neural degeneration compared with electrodes located within the scala tympani. In conclusion, the present study has shown that the reimplantation of a multichannel scala, tympani electrode array can be achieved with minimal damage to the majority of cochlear structures. Increased insertion trauma, resulting in new bone formation and spiral ganglion cell loss, can occur in the lower basal turn in cases where the electrode entry point is difficult to identify due to proliferation of granulation and fibrous tissue.

  16. The Repeatable Battery for the Assessment of Neuropsychological Status for Hearing Impaired Individuals (RBANS-H) before and after Cochlear Implantation: A Protocol for a Prospective, Longitudinal Cohort Study.

    Science.gov (United States)

    Claes, Annes J; Mertens, Griet; Gilles, Annick; Hofkens-Van den Brandt, Anouk; Fransen, Erik; Van Rompaey, Vincent; Van de Heyning, Paul

    2016-01-01

    Background: Currently, an independent relationship between hearing loss and cognitive decline in older adults is suggested by large prospective studies. In general, cochlear implants improve hearing and the quality of life in severely to profoundly hearing impaired older persons. However, little is known about the effects of cochlear implantation on the cognitive evolution in this population. Aim of the study: The primary goal of this prospective, longitudinal cohort study is to explore the cognitive profile of severely to profoundly postlingually hearing impaired subjects before and after cochlear implantation. In addition, the current study aims to investigate the relationship between the cognitive function, audiometric performances, quality of life, and self-reliance in these patients. Methods: Twenty-five patients aged 55 or older, scheduled for cochlear implantation, will be enrolled in the study. They will be examined prior to implantation, at 6 and 12 months after implantation and annually thereafter. The test battery consists of (1) a cognitive examination, using the Repeatable Battery for the Assessment of Neuropsychological Status adapted for Hearing impaired persons (RBANS-H), (2) an audiological examination, including unaided and aided pure tone audiometry, speech audiometry in quiet and speech audiometry in noise, (3) the administration of four questionnaires evaluating quality of life and subjective hearing benefit and (4) a semi-structured interview about the self-reliance of the participant. Discussion: Up until now only one study has been conducted on this topic, focusing on the short-term effects of cochlear implantation on cognition in older adults. The present study is the first study to apply a comprehensive neuropsychological assessment adapted for severely to profoundly hearing impaired subjects in order to investigate the cognitive capabilities before and after cochlear implantation. Trial registration: The present protocol is

  17. Can cochlear implantation improve neurocognition in the aging population?

    Directory of Open Access Journals (Sweden)

    Völter C

    2018-04-01

    Full Text Available Christiane Völter,1 Lisa Götze,1 Stefan Dazert,1 Michael Falkenstein,2,3 Jan Peter Thomas1 1Department of Otorhinolaryngology, Head and Neck Surgery, Ruhr University Bochum, St. Elisabeth-Hospital, Bochum, Germany; 2Institute for Work, Learning and Ageing (ALA, Bochum, Germany; 3Leibniz Research Centre for Working Environment and Human Factors, Dortmund, Germany Introduction: The relationship between cognition and the ability to hear is well known. Due to changes in demographics, the number of people with sensorineural hearing loss and cognitive impairment is increasing. The aim of this study was to identify the impact of hearing rehabilitation via cochlear implantation on cognitive decline among the aging population. Patients and methods: This prospective study included 60 subjects aged between 50 and 84 years (mean 65.8 years, SD=8.9 with a severe to profound bilateral hearing impairment. A computer-based evaluation of short- and long-term memory, processing speed, attention, working memory and inhibition was performed prior to surgery as well as 6 and 12 months after cochlear implantation. Additionally, speech perception at 65 and 80 dB (Freiburger monosyllabic speech test as well as disease-related (Nijmegen Cochlear Implant Questionnaire and general (WHOQOL-OLD quality of life were assessed. Results: Six months postimplantation, speech perception, quality of life and also neurocognitive abilities significantly increased. The most remarkable improvement after 6 months was detected in executive functions such as attention (p<0.001, inhibition (p=0.025 and working memory (n-back: p=0.002; operation span task: p=0.008, followed by delayed recall (p=0.03. In contrast, long-term memory showed a significant change of performance only after 12 months (p=0.021. After 6 months, most cognitive domains remained stable, except working memory assessed by the operation span task, which significantly improved between 6 and 12 months (p<0.001. No

  18. Parental mode of communication is essential for speech and language outcomes in cochlear implanted children

    DEFF Research Database (Denmark)

    Percy-Smith, Lone; Cayé-Thomasen, Per; Breinegaard, Nina

    2010-01-01

    The present study demonstrates a very strong effect of the parental communication mode on the auditory capabilities and speech/language outcome for cochlear implanted children. The children exposed to spoken language had higher odds of scoring high in all tests applied and the findings suggest...... a very clear benefit of spoken language communication with a cochlear implanted child....

  19. Cyborgization: Deaf Education for Young Children in the Cochlear Implantation Era

    Science.gov (United States)

    Valente, Joseph Michael

    2011-01-01

    The author, who was raised oral deaf himself, recounts a visit to a school for young deaf children and discovers that young d/Deaf children and their rights are subverted by the cochlear implantation empire. The hypercapitalist, techno-manic times of cochlear implantation has wreaked havoc to the lives of not only young children with deafness but…

  20. Effects of residual hearing on cochlear implant outcomes in children: A systematic-review.

    Science.gov (United States)

    Chiossi, Julia Santos Costa; Hyppolito, Miguel Angelo

    2017-09-01

    to investigate if preoperative residual hearing in prelingually deafened children can interfere on cochlear implant indication and outcomes. a systematic-review was conducted in five international databases up to November-2016, to locate articles that evaluated cochlear implantation in children with some degree of preoperative residual hearing. Outcomes were auditory, language and cognition performances after cochlear implant. The quality of the studies was assessed and classified according to the Oxford Levels of Evidence table - 2011. Risk of biases were also described. From the 30 articles reviewed, two types of questions were identified: (a) what are the benefits of cochlear implantation in children with residual hearing? (b) is the preoperative residual hearing a predictor of cochlear implant outcome? Studies ranged from 04 to 188 subjects, evaluating populations between 1.8 and 10.3 years old. The definition of residual hearing varied between studies. The majority of articles (n = 22) evaluated speech perception as the outcome and 14 also assessed language and speech production. There is evidence that cochlear implant is beneficial to children with residual hearing. Preoperative residual hearing seems to be valuable to predict speech perception outcomes after cochlear implantation, even though the mechanism of how it happens is not clear. More extensive researches must be conducted in order to make recommendations and to set prognosis for cochlear implants based on children preoperative residual hearing. Copyright © 2017 Elsevier B.V. All rights reserved.

  1. Spelling in Written Stories by School-Age Children with Cochlear Implants

    Science.gov (United States)

    Straley, Sara G.; Werfel, Krystal L.; Hendricks, Alison Eisel

    2016-01-01

    This study evaluated the spelling of 3rd to 6th grade children with cochlear implants in written stories. Spelling was analysed using traditional correct/incorrect scoring as well as the Spelling Sensitivity Score, which provides linguistic information about spelling attempts. Children with cochlear implants spelled 86 per cent of words in stories…

  2. Sequential bilateral cochlear implantation in children: parents' perspective and device use.

    NARCIS (Netherlands)

    Sparreboom, M.; Leeuw, A.R.; Snik, A.F.M.; Mylanus, E.A.M.

    2012-01-01

    OBJECTIVE: The purpose of this study was (1) to measure parental expectations before surgery of a sequentially placed second cochlear implant and compare these results with parental observations postoperatively and (2) to measure device use of the second cochlear implant and compare to unilateral

  3. Quality of life and cochlear implantation in Usher syndrome type I.

    NARCIS (Netherlands)

    Damen, G.W.J.A.; Pennings, R.J.E.; Snik, A.F.M.; Mylanus, E.A.M.

    2006-01-01

    OBJECTIVES: The objectives of this descriptive, retrospective study were to evaluate quality of life, hearing, and vision in patients with Usher syndrome type I with and without cochlear implant. METHODS: Quality of life (QoL) of 14 patients with Usher type I (USH1) with a cochlear implant (CI)

  4. Advances in cochlear implant telemetry: evoked neural responses, electrical field imaging, and technical integrity.

    NARCIS (Netherlands)

    Mens, L.H.M.

    2007-01-01

    During the last decade, cochlear implantation has evolved into a well-established treatment of deafness, predominantly because of many improvements in speech processing and the controlled excitation of the auditory nerve. Cochlear implants now also feature telemetry, which is highly useful to

  5. Protective role of hydrogen sulfide against noise-induced cochlear damage: a chronic intracochlear infusion model.

    Directory of Open Access Journals (Sweden)

    Xu Li

    Full Text Available BACKGROUND: A reduction in cochlear blood flow plays an essential role in noise-induced hearing loss (NIHL. The timely regulation of cochlear perfusion determines the progression and prognosis of NIHL. Hydrogen sulfide (H(2S has attracted increasing interest as a vasodilator in cardiovascular systems. This study identified the role of H(2S in cochlear blood flow regulation and noise protection. METHODOLOGY/PRINCIPAL FINDINGS: The gene and protein expression of the H(2S synthetase cystathionine-γ-lyase (CSE in the rat cochlea was examined using immunofluorescence and real-time PCR. Cochlear CSE mRNA levels varied according to the duration of noise exposure. A chronic intracochlear infusion model was built and artificial perilymph (AP, NaHS or DL-propargylglycine (PPG were locally administered. Local sodium hydrosulfide (NaHS significantly increased cochlear perfusion post-noise exposure. Cochlear morphological damage and hearing loss were alleviated in the NaHS group as measured by conventional auditory brainstem response (ABR, cochlear scanning electron microscope (SEM and outer hair cell (OHC count. The highest percentage of OHC loss occurred in the PPG group. CONCLUSIONS/SIGNIFICANCE: Our results suggest that H(2S plays an important role in the regulation of cochlear blood flow and the protection against noise. Further studies may identify a new preventive and therapeutic perspective on NIHL and other blood supply-related inner ear diseases.

  6. Rational use of diagnostic radiology

    International Nuclear Information System (INIS)

    Racoveanu, N.T.; Volodin, V.

    1992-01-01

    The escalating number of radiodiagnostic investigations has, as a consequence, an increase in medical irradiation of patients and of cost of radiological services. Radiologists in USA and UK have since early 1970 questioned the efficacy of various radiological investigations and produced substantial evidence that more rational approaches are necessary. WHO initiated, in 1977, a programme in this direction which has issued four technical reports which give practical recommendations on how to rationalize the use of radiological examinations. Three main directions are considered: (1) Abandonment of routine radiological examinations, as procedures with no clinical or epidemiologic significance and which represent a waste of resources and patient dose. (2) Patient selection for various radiological investigations based on clinical criteria (high, intermediate, low yield). Selected patients have an increased prevalence of the given disease and the predictive value of radiological investigation is much higher. (3) Use of diagnostic algorithms with higher cost/efficiency and risk/benefit ratios, improving the outcome of radiological examinations

  7. Cochlear implantation in the world's largest medical device market: utilization and awareness of cochlear implants in the United States.

    Science.gov (United States)

    Sorkin, Donna L

    2013-03-01

    Provision of cochlear implants (CIs) for those within the criteria for implantation remains lower in the United States than in some other developed nations. When adults and children are grouped together, the rate of utilization/provision remains low at around 6%. For children, the provision rate is about 50% of those who could benefit from an implant, compared with figures of about 90% for the Flanders part of Belgium, the United Kingdom and other European countries. The probable reasons for this underprovision include: low awareness of the benefits of CIs among the population; low awareness among health-care professionals; the lack of specific referral pathways; some political issues relating to the Deaf Community; and financial issues related to health provision. Such financial issues result in situations which either fail to provide for access to implants or provide too low a level of the necessary funding, especially for low-income individuals covered by public health-care programs such as Medicaid. These issues might be mitigated by adoption and publication of standards for best clinical practices for CI provision, availability of current cost-effectiveness data, and the existence of an organization dedicated to cochlear implantation. Such an organization, the American Cochlear Implant Alliance (ACI Alliance), was recently organized and is described in the paper by Niparko et al. in this Supplement.

  8. Standardization of reliability reporting for cochlear implants: an interim report.

    Science.gov (United States)

    Backous, Douglas D; Watson, Stacey D

    2007-04-01

    To propose a standard definition of "out of specification" for cochlear implants and a paradigm for inclusion of category C of the ISO standard 5841-2:2000 for reporting in cumulative survival statistics. A standard definition of "out of specification" and consistent reporting by manufacturers of cochlear implants will create a fair and consistent representation of cumulative survival. This will allow discernment of differences between manufacturers for reliability and for detection of trends in reliability between model types from the same manufacturer. Three separate meetings with representatives of the three manufacturers of cochlear implants marketed in the United States were staged over a 13-mo period. Standard questions, created by the authors, were addressed by each representative to determine the current state of device reliability reporting. Results were presented to clinicians at the William House Cochlear Implant study Group and the Implantable devices sub-committee of the American Academy of Otolaryngology (2004, 2005) and at the 8th International Cochlear Implant Conference (2004) for feedback. After assimilation of feedback by all parties, the standard was written and reviewed by representatives from each manufacturer for accuracy of data. A complaint-driven standard was developed. A "cochlear implant" as an internal device placed and skin closed in surgery. An internal device is "out of specification" when one or more technical characteristics is outside the limits of normal function and results in explantation or non-use by the patient." Children will be reported separately from adults, each model of device will be reported on annually, a minimum of 200 devices must be in each model group for Cumulative Survival Reporting (CSR). Confidence limits are set at 95%. Explants will be determined to be "biological" or "technical." Technical explants are included in CSR reports. Devices failing to meet specifications set by the manufacturer, not in use but

  9. Radiological diagnosis in traumatology

    International Nuclear Information System (INIS)

    Frahm, R.

    2001-01-01

    This loose-leaf publication covers all radiological problems that may possibly occur in accident surgery. The focus is on conventional radiological diagnosis. The physical and technical fundamentals of diagnostic examination methods are discussed, followed by practical hints on radiation protection, technical equipment and quality assurance, as well as accurate information on the procedure of taking and interpreting standard X-ray pictures. The indications for standard X-raying, tomography, CT and MRT are presented in consideration of the radiation exposure incurred by the patient. The reader is also informed on the dynamics and varying morphology of bone fracture healing, potential disturbances of callus formation and reconstruction, as well as on possible complications. The main section of the book discusses injuries of the skull, spinal cord, pectoral girdle, upper arm, elbow and lower arm, wrist and hands, pelvis, hip joint, knee and upper and lower leg, ankle joint and foot, thorax and abdomen. (orig.)

  10. Radiology for veterinarians

    International Nuclear Information System (INIS)

    Tempel, K.

    1983-01-01

    The author has made an attempt to comprise the extensive and heterogenic area of radiological topics in the sense of a studying support for the second part of the veterinary examination and as an introduction to the entire area. Numerous details, exact physical derivations and more extensive radiological tables and graphs had to be left out to achieve the brief and understandable form. On the other hand, in addition to the test subjects, at least a few of the particularly up-to-date problems of this branch had to be emphasized and the data necessary to assess them had to be given. This explains the extensive form of the manuscript and the frequent occurrence of numbers, especially in the chapters radioecology, radiobiology and radiotoxicology. (orig./MG) With 65 figs., 76 tabs [de

  11. Paediatric interventional radiology

    International Nuclear Information System (INIS)

    McLaren, Clare

    2014-01-01

    Paediatric interventional radiology (PIR) is a rapidly-growing subspecialty, which offers a wide range of procedures applicable to almost all areas of hospital paediatrics. There are many important differences between paediatric and adult practice in interventional radiology, including disease processes and treatment goals, anatomical considerations, periprocedural patient management, radiation exposure optimisation and legal aspects. The use of retrievable or absorbable interventional devices such as stents will probably become more widespread in PIR practice. Recent advances in the technology of imaging equipment have been accompanied by an increase in the complexity of the work done by the radiographer. These developments present challenges and opportunities related to training and maintenance of skills, staffing arrangements, and the potential for advanced practice. It is likely that specialisation in PIR will become a more common role for radiographers in the future

  12. Computer assisted radiology

    International Nuclear Information System (INIS)

    Lemke, H.U.; Jaffe, C.C.; Felix, R.

    1993-01-01

    The proceedings of the CAR'93 symposium present the 126 oral papers and the 58 posters contributed to the four Technical Sessions entitled: (1) Image Management, (2) Medical Workstations, (3) Digital Image Generation - DIG, and (4) Application Systems - AS. Topics discussed in Session (1) are: picture archiving and communication systems, teleradiology, hospital information systems and radiological information systems, technology assessment and implications, standards, and data bases. Session (2) deals with computer vision, computer graphics, design and application, man computer interaction. Session (3) goes into the details of the diagnostic examination methods such as digital radiography, MRI, CT, nuclear medicine, ultrasound, digital angiography, and multimodality imaging. Session (4) is devoted to computer-assisted techniques, as there are: computer assisted radiological diagnosis, knowledge based systems, computer assisted radiation therapy and computer assisted surgical planning. (UWA). 266 figs [de

  13. Radiology and Ethics Education.

    Science.gov (United States)

    Camargo, Aline; Liu, Li; Yousem, David M

    2017-09-01

    The purpose of this study is to assess medical ethics knowledge among trainees and practicing radiologists through an online survey that included questions about the American College of Radiology Code of Ethics and the American Medical Association Code of Medical Ethics. Most survey respondents reported that they had never read the American Medical Association Code of Medical Ethics or the American College of Radiology Code of Ethics (77.2% and 67.4% of respondents, respectively). With regard to ethics education during medical school and residency, 57.3% and 70.0% of respondents, respectively, found such education to be insufficient. Medical ethics training should be highlighted during residency, at specialty society meetings, and in journals and online resources for radiologists.

  14. Safeness of radiological machinery

    International Nuclear Information System (INIS)

    Yokoyama, Shun

    1979-01-01

    The human factors affecting the safeness of radiological machinery, which are often very big and complicated machines, are described from the stand point of handling. 20 to 50% of the troubles on equipments seem to be caused by men. This percentage will become even higher in highly developed equipments. Human factors have a great influence on the safeness of radiological equipments. As the human factors, there are sensory factors and knowledge factors as well as psychological factors, and the combination of these factors causes mishandling and danger. Medical services at present are divided in various areas, and consist of the teamwork of the people in various professions. Good human relationship, education and control are highly required to secure the safeness. (Kobatake, H.)

  15. Artificial intelligence in radiology.

    Science.gov (United States)

    Hosny, Ahmed; Parmar, Chintan; Quackenbush, John; Schwartz, Lawrence H; Aerts, Hugo J W L

    2018-05-17

    Artificial intelligence (AI) algorithms, particularly deep learning, have demonstrated remarkable progress in image-recognition tasks. Methods ranging from convolutional neural networks to variational autoencoders have found myriad applications in the medical image analysis field, propelling it forward at a rapid pace. Historically, in radiology practice, trained physicians visually assessed medical images for the detection, characterization and monitoring of diseases. AI methods excel at automatically recognizing complex patterns in imaging data and providing quantitative, rather than qualitative, assessments of radiographic characteristics. In this Opinion article, we establish a general understanding of AI methods, particularly those pertaining to image-based tasks. We explore how these methods could impact multiple facets of radiology, with a general focus on applications in oncology, and demonstrate ways in which these methods are advancing the field. Finally, we discuss the challenges facing clinical implementation and provide our perspective on how the domain could be advanced.

  16. Radiological control implementation guide

    International Nuclear Information System (INIS)

    Hamley, S.A.

    1993-01-01

    A manual is being developed to explain to line managers how radiological controls are designed and implemented. The manual also fills a gap in the Health Physics literature between textbooks and on-the-floor procedures. It may be helpful to new Health Physicists with little practical experience and to those wishing to improve self-assessment, audit, and appraisal processes. Many audits, appraisals, and evaluations have indicated a need for cultural change, increased vigor and example, and more effective oversight by line management. Inadequate work controls are a frequent and recurring problem identified in occurrence reports and accident investigations. Closer study frequently indicates that many line managers are willing to change and want to achieve excellence, but no effective guidance exists that will enable them to understand and implement a modern radiological control program

  17. Water radiological surveillance (II)

    International Nuclear Information System (INIS)

    Pablo San Martin de, M.

    2008-01-01

    This paper summarizes the characteristics of the Environmental Surveillance Radiological Networks (ESRN) currently operating in CEDEX. In the first part, the Spanish Continental Waters ESRN has been presented. This second one describes Spanish Costal Waters ESRN and the High Sensitivity Networks in Continental and Marine Waters. It also presents the Radiological Surveillance of Drinking Waters that CEDEX carries out in waters of public consumption management by the Canal de Isabel II (CYII) and by the Mancomunity of Canals Taibilla (M.C.T.). The legislation applicable in each case is reviewed as well. Due to its extension the article has been divided into two parts. As Spanish Continental Waters ESRN has been reviewed in the first part, the others ESRN are discussed in this second one. (Author) 10 refs

  18. Digital radiology and ultrasound

    International Nuclear Information System (INIS)

    Todd-Pokropek, A.

    1991-01-01

    With the access to digital methods for handling and processing images in general, many medical imaging methods are becoming more effectively handled digitally. This applies in particular to basically digital techniques such as CT and MR but also now includes Nuclear Medicine (NM), Ultrasound (US) and a variety of radiological procedures such as Digital Subtraction Angiography (DSA) and Fluoroscopy (DF). The access to conventional projection images by stimulatable plates (CR) or by digitization of film makes all of radiology potentially accessible, and the management of such images by a network is the basic aim of Picture Archiving and Communication Systems (PACS). However, it is suggested that in order for such systems to be of greater value, that way in which such images are treated needs to change, that is, digital images can be used to derive additional clinical value by appropriate processing

  19. Data mining in radiology

    International Nuclear Information System (INIS)

    Kharat, Amit T; Singh, Amarjit; Kulkarni, Vilas M; Shah, Digish

    2014-01-01

    Data mining facilitates the study of radiology data in various dimensions. It converts large patient image and text datasets into useful information that helps in improving patient care and provides informative reports. Data mining technology analyzes data within the Radiology Information System and Hospital Information System using specialized software which assesses relationships and agreement in available information. By using similar data analysis tools, radiologists can make informed decisions and predict the future outcome of a particular imaging finding. Data, information and knowledge are the components of data mining. Classes, Clusters, Associations, Sequential patterns, Classification, Prediction and Decision tree are the various types of data mining. Data mining has the potential to make delivery of health care affordable and ensure that the best imaging practices are followed. It is a tool for academic research. Data mining is considered to be ethically neutral, however concerns regarding privacy and legality exists which need to be addressed to ensure success of data mining

  20. Radiological safety and control

    International Nuclear Information System (INIS)

    Kim, Jang Hee; Kim, Ki Sub

    1995-01-01

    The practical objective of radiological safety control is intended for achievement and maintenance of appropreately safe condition in environmental control for activities involving exposure from the use of radiation. In order to establish these objectives, we should be to prevent deterministic effects and to limit the occurrence stochastic effects to level deemed to be acceptable by the application of general principles of radiation protection and systems of dose limitation based on ICRP recommendations. 34 tabs., 19 figs., 11 refs. (Author) .new

  1. "Patient care in radiology"

    DEFF Research Database (Denmark)

    Bro Brask, Kirsten; Birkelund, Regner

    2014-01-01

    The aim of this study was to research how the staff experience care expressed during the brief encounter with the patients in a diagnostic imaging department. This was a qualitative study with a phenomenological and hermeneutical frame of reference. The data were collected using field observation...... was electronically forwarded. And, care expressed in between was perceived as care in the traditional sense and termed as “patient care in radiology.”...

  2. Fundamentals of radiological protection

    International Nuclear Information System (INIS)

    Wells, J.; Mill, A.J.; Charles, M.W.

    1978-05-01

    The basic processes of living cells which are relevant to an understanding of the interaction of ionizing radiation with man are described. Particular reference is made to cell death, cancer induction and genetic effects. This is the second of a series of reports which present the fundamentals necessary for an understanding of the bases of regulatory criteria such as those recommended by the International Commision on Radiological Protection (ICRP). Others consider basic radiation physics and the biological effects of ionizing radiation. (author)

  3. Radiological containment handbook

    International Nuclear Information System (INIS)

    1982-10-01

    The purpose of this NUREG is to be used as a reference text. It is meant to be used by the working personnel as a guide for using temporary radiological containments. The installing group and health physics group may vary among organizations but responsibilities and duties will not change. It covers installation and inspection containments; working and operating guidelines; operating requirement; emergency procedures; and removal of containments

  4. Microcephaly: a radiological review

    Energy Technology Data Exchange (ETDEWEB)

    Tarrant, Ailbhe; Garel, Catherine; Germanaud, David; Lenoir, Marion; Pointe, Hubert Ducou le [Universite Paris VI Pierre et Marie Curie, Radiology Department, Hopital d' Enfants Armand-Trousseau, Paris (France); Villemeur, Thierry Billette de; Mignot, Cyril [Universite Paris V Rene Descartes, CNRS (UMR 8104), Inserm, U567, Institut Cochin, Paris (France); Universite Paris VI Pierre et Marie Curie, Paediatric Neurology Department, Hopital d' Enfants Armand-Trousseau, Paris (France)

    2009-08-15

    Microcephaly results from inadequate brain growth during development. It may develop in utero, and therefore be present at birth, or may develop later as a result of perinatal events or postnatal conditions. The aetiology of microcephaly may be congenital (secondary to cerebral malformations or metabolic abnormalities) or acquired, most frequently following an ischaemic insult. This distinct radiological and pathological entity is reviewed with a specific focus on aetiology. (orig.)

  5. Training in radiological protection

    International Nuclear Information System (INIS)

    Medina G, E.

    2014-08-01

    In the Peru, according to the current regulations, people that work with ionizing radiations should have an authorization (individual license), which is granted by the Technical Office of the National Authority that is the technical body of the Instituto Peruano de Energia Nuclear (IPEN) manager of the control of ionizing radiations in the country. The individual license is obtained after the applicant fulfills the requested requirements, as having safety knowledge and radiological protection. Since its founding in 1972, the Centro Superior de Estudios Nucleares (CSEN) of the IPEN has carried out diverse training courses in order to that people can work in a safe way with ionizing radiations in medicine, industry and research, until the year 2013 have been organized 2231 courses that have allowed the training of 26213 people. The courses are organized according to the specific work that is carried out with radiations (medical radio-diagnostic, dental radiology, nuclear medicine, radiotherapy, industrial radiography, nuclear meters, logging while drilling, etc.). In their majority the courses are directed to people that will make use of radiations for first time, but refresher courses are also granted in the topic. The CSEN also carries out the Master degree programs highlighting the Second Professional Specialization in Radiological Protection carried out from the year 2004 with the support of the National University of Engineering. To the present has been carried out 2 programs and there is other being developed. In this work is shown the historical evolution of the radiological protection courses as well as the important thing that they are to work in a safe way in the country. (Author)

  6. Radiologic findings of dwarfism

    Energy Technology Data Exchange (ETDEWEB)

    Hwang, M. S.; Oh, K. K.; Park, C. Y.; Kim, D. H. [Yonsei University, College of Medicine, Seoul (Korea, Republic of); Kim, D. H. [Yonsei Univ., Seoul (Korea, Republic of)

    1981-06-15

    The stature of human is very important factor in human-being, especially in childhood. The stature depends on various different conditions, such as familial factor, constitutional factor, chromosomal anomalies, skeletal disorders, or endocrinopathies. The early diagnosis of dwarfism is very important problem, because if appropriate treatment is delayed, the complication or sequales are more increased. The survey of familial history or patient's past history, detail check up of physical examination, radiological evaluation, and other laboratory examinations are essentially needed for the accurate diagnosis of dwarfism. Among the patients admitted to Yonsei University college of Medicine, Severance Hospital since 1963, with chief complaint of short stature or other associated diseases, an analysis of radiological findings were made for the 72 cases of chromosomal anomalies, skeletal dysplasia, and cretinism in which radiologic evaluation was available. The conclusions are as follows; 1. The cause of short stature are chromosomal anomalies (48 cases), skeletal dysplasia (14 cases) and cretinism (10 cases). 2. in chromosomal anomalies, 43 cases of mongolism and 5 cease of Turner's syndrome are noted. In mongolism, 18 cases among the 30 cases below 1 year old are distributed below the 10 percentile of height. On radiologic findings, 11 paired ribs (22/43), congenital heart disease (14/43), decreased iliac index (8/12), and associated anomalies or diseases, such as pneumonia (14 cases), C1-C2 dislocation (1 case), imperforated anus (1 case), Morgagni's hernia (1 case) and leukemia with sepsis (1 case). In Turner's syndrome, decreased bone density (5/5), positive metacarpal sign (2/5), positive carpal sign (1/5), change of knee joint (3/5), hypoplasia of (1/3), and increased carrying angle of elbows (1/3) are noted.

  7. Radiologic findings of dwarfism

    International Nuclear Information System (INIS)

    Hwang, M. S.; Oh, K. K.; Park, C. Y.; Kim, D. H.; Kim, D. H.

    1981-01-01

    The stature of human is very important factor in human-being, especially in childhood. The stature depends on various different conditions, such as familial factor, constitutional factor, chromosomal anomalies, skeletal disorders, or endocrinopathies. The early diagnosis of dwarfism is very important problem, because if appropriate treatment is delayed, the complication or sequales are more increased. The survey of familial history or patient's past history, detail check up of physical examination, radiological evaluation, and other laboratory examinations are essentially needed for the accurate diagnosis of dwarfism. Among the patients admitted to Yonsei University college of Medicine, Severance Hospital since 1963, with chief complaint of short stature or other associated diseases, an analysis of radiological findings were made for the 72 cases of chromosomal anomalies, skeletal dysplasia, and cretinism in which radiologic evaluation was available. The conclusions are as follows; 1. The cause of short stature are chromosomal anomalies (48 cases), skeletal dysplasia (14 cases) and cretinism (10 cases). 2. in chromosomal anomalies, 43 cases of mongolism and 5 cease of Turner's syndrome are noted. In mongolism, 18 cases among the 30 cases below 1 year old are distributed below the 10 percentile of height. On radiologic findings, 11 paired ribs (22/43), congenital heart disease (14/43), decreased iliac index (8/12), and associated anomalies or diseases, such as pneumonia (14 cases), C1-C2 dislocation (1 case), imperforated anus (1 case), Morgagni's hernia (1 case) and leukemia with sepsis (1 case). In Turner's syndrome, decreased bone density (5/5), positive metacarpal sign (2/5), positive carpal sign (1/5), change of knee joint (3/5), hypoplasia of (1/3), and increased carrying angle of elbows (1/3) are noted

  8. Radiological safety and control

    Energy Technology Data Exchange (ETDEWEB)

    Chang, Sea Young; Yoo, Y S; Lee, J C; Lee, T Y; Lee, J L; Kim, B W; Lee, B J; Chung, K K; Chung, R I; Kim, J S; Lee, H S; Han, Y D; Lee, J I; Lee, K C; Yoon, J H; Sul, C W; Kim, C K; Yoon, K S; Seo, K W; Yoon, Y C [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of)

    1996-01-01

    This report describes the annual results of radiological safety and control program of 1995. This program consists of working area monitoring including HANARO, personnel radiation monitoring, education for radiation protection. As a result, the objectives of radiation protection have been achieved satisfactorily through the activities mentioned above. Also, the calibration services were provided to insure accurate radiation measurement in the radiation working places. 21 figs., 39 tabs., 5 refs. (Author) .new.

  9. Radiological physics in Sweden

    International Nuclear Information System (INIS)

    Walstam, Rune

    1980-01-01

    Development of radiological or radiation physics as a separate discipline in Sweden is outlined. Growth in number of hospital physicists is compared with that of some other countries for the period 1950-1975. The main duties of hospital physicists are described. Undergraduate and postgraduate courses in radiation physics in Sweden are discussed. A microtron and a multi-source cobalt-60 unit are described. (M.G.B.)

  10. Computer-assisted radiology

    International Nuclear Information System (INIS)

    Lemke, H.U.

    1988-01-01

    New digital imaging modalities and more sophisticated image processing systems will have a profound effect on those areas of medicine concerned with imaging. This mainly means computer-assisted radiology (CAR) and implies a transition from analog film systems to digital imaging systems, integration of digital imaging modalities through picture archiving and communication systems (PACS) and the graduated employment of image-oriented medical work stations (MWS) for computer-assisted representation, communication, diagnosis, and therapy planning. (orig.) [de

  11. Fundamentals of radiological protection

    International Nuclear Information System (INIS)

    Mill, A.J.; Charles, M.W.; Wells, J.

    1978-04-01

    A review is presented of basic radiation physics with particular relevance to radiological protection. The processes leading to the production and absorption of ionising radiation are outlined, and the important dosimetric quantities and their units of measurements. The review is the first of a series of reports presenting the fundamentals necessary for an understanding of the basis of regulatory criteria such as those recommended by the ICRP. (author)

  12. Radiological diagnosis of fractures

    International Nuclear Information System (INIS)

    Finlay, D.B.L.; Allen, M.J.

    1984-01-01

    This book is about radiology of fractures. While it contains sections of clinical features it is not intended that readers should rely entirely upon these for the diagnosis and management of the injured patient. As in the diagnosis and treatment of all medical problems, fracture management must be carried out in a logical step-by-step fashion - namely, history, examination, investigation, differential diagnosis, diagnosis and then treatment. Each section deals with a specific anatomical area and begins with line drawings of the normal radiographs demonstrating the anatomy. Accessory views that may be requested, and the indications for these, are included. Any radiological pitfalls for the area in general are then described. The fractures in adults are then examined in turn, their radiological features described, and any pitfalls in their diagnosis discussed. A brief note of important clinical findings is included. A brief mention is made of pediatric fractures which are of significance and their differences to the adult pattern indicated. Although fractures can be classified into types with different characteristics, in life every fracture is individual. Fractures by and large follow common patterns, but many have variations

  13. Deep Learning in Radiology.

    Science.gov (United States)

    McBee, Morgan P; Awan, Omer A; Colucci, Andrew T; Ghobadi, Comeron W; Kadom, Nadja; Kansagra, Akash P; Tridandapani, Srini; Auffermann, William F

    2018-03-29

    As radiology is inherently a data-driven specialty, it is especially conducive to utilizing data processing techniques. One such technique, deep learning (DL), has become a remarkably powerful tool for image processing in recent years. In this work, the Association of University Radiologists Radiology Research Alliance Task Force on Deep Learning provides an overview of DL for the radiologist. This article aims to present an overview of DL in a manner that is understandable to radiologists; to examine past, present, and future applications; as well as to evaluate how radiologists may benefit from this remarkable new tool. We describe several areas within radiology in which DL techniques are having the most significant impact: lesion or disease detection, classification, quantification, and segmentation. The legal and ethical hurdles to implementation are also discussed. By taking advantage of this powerful tool, radiologists can become increasingly more accurate in their interpretations with fewer errors and spend more time to focus on patient care. Copyright © 2018 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.

  14. Safety aspects in radiology

    International Nuclear Information System (INIS)

    Silva, D.C. da.

    1991-05-01

    The development of a program for the evaluation of the physical installations and operational procedures in diagnostic radiology with respect to radiation-safety is described. In addition, a proposal for the quality analysis of X-ray equipment and film-processing is presented. The purpose is both to ensure quality and safety of the radiology service, as well as to aid in the initial and in-service training of the staff. Interviews with patients, staff practicing radiology at a wide range of levels and the controlling authorities were carried out in the State of Rio de Janeiro in order to investigate the existence and the effective use of personal radioprotection equipment as well as user's and staff's concern for radiation safety. Additionally physical measurements were carried out in University Hospitals in Rio de Janeiro to assess the quality of equipment in day-to-day use. It was found that in the locations which did not have routine maintenance the equipment was generally in a poor state which lead to a high incidence of repetition of examinations and the consequent financial loss. (author)

  15. Radiological findings in angiofibroma

    Energy Technology Data Exchange (ETDEWEB)

    Schick, B. [Univ. of Marburg (Germany). Dept. of Ear, Nose and Throat Diseases; Kahle, G. [Univ. of Marburg, (Germany). Inst.of Radiology

    2000-11-01

    Surgery after pre-operative embolization has become the main treatment modality in angiofibroma therapy. As surgical planning is based on precise pre-operative tumour evaluation, knowledge of the characteristic growth patterns is of great interest. Analysis of tumour extension and blood supply, as well as methods of controlling intra-operative bleeding, help in determining the appropriate surgical approach. Though benign, angiofibroma demonstrates a locally aggressive nature. This fibrovascular tumour is characterised by typical radiological findings and by predictable growth patterns. The tumour extension and blood supply can be accurately determined by CT, MR imaging and angiography. With classic radiological findings, no pre-operative biopsy is necessary in most angiofibromas. Advances in radiological imaging have contributed to improved surgical planning and tumour resection. The surgeon is able to select the least traumatic approach with secure haemostatic control, which is also critical for avoiding the disturbance of facial skeletal growth in this group of young patients. Embolization, pre-operative autologous donation and the cell saver system for immediate retransfusion of the collected blood after filtration, are important tools for dealing with blood loss in angiofibroma surgery as they minimize homologous blood transfusion.

  16. Radiological Research Accelerator Facility

    International Nuclear Information System (INIS)

    Goldhagen, P.; Marino, S.A.; Randers-Pehrson, G.; Hall, E.J.

    1986-01-01

    The Radiological Research Accelerator Facility (RARAF) is based on a 4-MV Van de Graaff accelerator, which can be used to generate a variety of well-characterized radiation beams for research in radiobiology and radiological physics. It is part of the Radiological Research Laboratory (RRL), and its operation is supported as a National Facility by the US Department of Energy. RARAF is available to all potential users on an equal basis, with priorities based on the recommendations of a Scientific Advisory Committee. Facilities and services are provided to users, but the research projects themselves must be supported separately. This chapter presents a brief description of current experiments being carried out at RARAF and of the operation of the Facility from January through June, 1986. Operation of the Facility for all of 1985 was described in the 1985 Progress Report for RARAF. The experiments described here were supported by various Grants and Contracts from NIH and DOE and by the Statens Stralskyddsinstitut of Sweden

  17. Radiological manifestations of melioidosis

    International Nuclear Information System (INIS)

    Lim, K.S.; Chong, V.H.

    2010-01-01

    Melioidosis is a serious infection that is associated with high mortality. It is due to a Gram-negative bacterium, Burkholderia pseudomallei which is an environmental saprophyte found in wet soils. Melioidosis is endemic to northern Australia and the Southeast Asia. However, there is now increasing number of reports of imported cases to regions where this infection has not been previously encountered. Almost any organ can be affected. Like many other conditions, radiological imaging is an integral part of the diagnostic workup of melioidosis. Awareness of the various radiological manifestations can help direct appropriate investigations to achieve early diagnosis and the initiation of appropriate treatment. Generally, there are no known characteristic features on imaging that can specifically differentiate melioidosis from other infections. However, the 'honeycomb' appearance has been described to be characteristic for large melioidosis liver abscesses. Simultaneous involvement of various organs is also characteristics. To date, there are few data available on the radiological manifestations of melioidosis. The present pictorial essay describes melioidosis affecting the various organs.

  18. Working memory in Farsi-speaking children with normal development and cochlear implant.

    Science.gov (United States)

    Soleymani, Zahra; Amidfar, Meysam; Dadgar, Hooshang; Jalaie, Shohre

    2014-04-01

    Working memory has an important role in language acquisition and development of cognition skills. The ability of encoding, storage and retrieval of phonological codes, as activities of working memory, acquired by audition sense. Children with cochlear implant experience a period that they are not able to perceive sounds. In order to assess the effect of hearing on working memory, we investigated working memory as a cognition skill in children with normal development and cochlear implant. Fifty students with normal hearing and 50 students with cochlear implant aged 5-7 years participated in this study. Children educated in the preschool, the first and second grades. Children with normal development were matched based on age, gender, and grade of education with cochlear implant. Two components of working memory including phonological loop and central executive were compared between two groups. Phonological loop assessed by nonword repetition task and forward digit span. To assess central executive component backward digit span was used. The developmental trend was studied in children with normal development and cochlear implant as well. The effect of age at implantation in children with cochlear implants on components of working memory was investigated. There are significant differences between children with normal development and cochlear implant in all tasks that assess working memory (p memory between different grades showed significant differences both in children with normal development and in children with cochlear implant (p implied that children with cochlear implant may experience difficulties in working memory. Therefore, these children have problems in encoding, practicing, and repeating phonological units. The results also suggested working memory develops when the child grows up. In cochlear implant children, with decreasing age at implantation and increasing their experience in perceiving sound, working memory skills improved. Copyright © 2014 Elsevier

  19. The role of eABR with intracochlear test electrode in decision making between cochlear and brainstem implants: preliminary results.

    Science.gov (United States)

    Cinar, Betul Cicek; Yarali, Mehmet; Atay, Gamze; Bajin, Munir Demir; Sennaroglu, Gonca; Sennaroglu, Levent

    2017-09-01

    The objective of the study was to discuss the findings of intraoperative electrically evoked auditory brainstem response (eABR) test results with a recently designed intracochlear test electrode (ITE) in terms of their relation to decisions of cochlear or auditory brainstem implantation. This clinical study was conducted in Hacettepe University, Department of Otolaryngology, Head and Neck Surgery and Department of Audiology. Subjects were selected from inner ear malformation (IEM) database. Eleven subjects with profound sensorineural hearing loss were included in the current study with age range from 1 year 3 months to 4 years 3 months for children with prelingual hearing loss. There was only one 42-year-old post-lingual subject. eABR was recorded with an ITE and intraoperatively with an original cochlear implant (CI) electrode in 11 cases with different IEMs. Findings of eABR with ITE and their relation to the decision for CI or auditory brainstem implant (ABI) are discussed. Positive eABR test results were found to be dependent on close to normal cochlear structures and auditory nerve. The probability of positive result decreases with increasing degree of malformation severity. The prediction value of eABR via ITE on decision for hearing restoration was found to be questionable in this study. The results of eABR with ITE have predictive value on what we will get with the actual CI electrode. ITE appears to stimulate the cochlea like an actual CI. If the eABR is positive, the results are reliable. However, if eABR is negative, the results should be evaluated with preoperative audiological testing and MRI findings.

  20. The radiological diagnosis of bone tumors

    International Nuclear Information System (INIS)

    Freyschmidt, J.

    1979-01-01

    Since the definitive diagnosis of very many bone tumors is not only histological but also radiological it is important that the latter examination be of high quality. Prior to biopsy the differential diagnosis should be narrowed down as far as possible radiologically. The radiological procedures include conventional X-ray examination in two projections, tomography, angiography, and computerized tomography. Tomography can reveal the borders of the tumor and minute clacifications within the tumor. Angiography may show atypically vascularized areas and thus be helpful in choosing the best site for biopsy and in making a prognosis. It might reveal, for example, unusual vascularization or penetration of tumor into blood vessels. Computerized tomography allows precise delineation of the intraosseous and extraosseous borders of the tumor, and is particularly useful in this respect in regions in which angiography has its technical limitations, such as the pelvis and the spine. The radiological assessment of a tumor or tumor-like lesion should take account of the structural changes, the site of the lesion, and the age and sex of the patient. The report should include a statement about the malignancy of the lesion. (orig.) [de