WorldWideScience

Sample records for cochlear nerve monitoring

  1. Effect of cochlear nerve electrocautery on the adult cochlear nucleus.

    Science.gov (United States)

    Iseli, Claire E; Merwin, William H; Klatt-Cromwell, Cristine; Hutson, Kendall A; Ewend, Matthew G; Adunka, Oliver F; Fitzpatrick, Douglas C; Buchman, Craig A

    2015-04-01

    Electrocauterization and subsequent transection of the cochlear nerve induce greater injury to the cochlear nucleus than sharp transection alone. Some studies show that neurofibromatosis Type 2 (NF2) patients fit with auditory brainstem implants (ABIs) fail to achieve speech perception abilities similar to ABI recipients without NF2. Reasons for these differences remain speculative. One hypothesis posits poorer performance to surgically induced trauma to the cochlear nucleus from electrocautery. Sustained electrosurgical depolarization of the cochlear nerve may cause excitotoxic-induced postsynaptic nuclear injury. Equally plausible is that cautery in the vicinity of the cochlear nucleus induces necrosis. The cochlear nerve was transected in anesthetized adult gerbils sharply with or without bipolar electrocautery at varying intensities. Gerbils were perfused at 1, 3, 5, and 7 days postoperatively; their brainstem and cochleas were embedded in paraffin and sectioned at 10 μm. Alternate sections were stained with flourescent markers for neuronal injury or Nissl substance. In additional experiments, anterograde tracers were applied directly to a sectioned eighth nerve to verify that fluorescent-labeled profiles seen were terminating auditory nerve fibers. Cochlear nerve injury was observed from 72 hours postoperatively and was identical across cases regardless of surgical technique. Postsynaptic cochlear nucleus injury was not seen after distal transection of the nerve. By contrast, proximal transection was associated with trauma to the cochlear nucleus. Distal application of bipolar electrocautery seems safe for the cochlear nucleus. Application near the root entry zone must be used cautiously because this may compromise nuclear viability needed to support ABI stimulation.

  2. Intraoperative cochlear nerve mapping with the mobile cochlear nerve compound action potential tracer in vestibular schwannoma surgery.

    Science.gov (United States)

    Watanabe, Nobuyuki; Ishii, Takuya; Fujitsu, Kazuhiko; Kaku, Shogo; Ichikawa, Teruo; Miyahara, Kosuke; Okada, Tomu; Tanino, Shin; Uriu, Yasuhiro; Murayama, Yuichi

    2018-05-18

    OBJECTIVE The authors describe the usefulness and limitations of the cochlear nerve compound action potential (CNAP) mobile tracer (MCT) that they developed to aid in cochlear nerve mapping during vestibular schwannoma surgery (VSS) for hearing preservation. METHODS This MCT device requires no more than 2 seconds for stable placement on the nerve to obtain the CNAP and thus is able to trace the cochlear nerve instantaneously. Simultaneous bipolar and monopolar recording is possible. The authors present the outcomes of 18 consecutive patients who underwent preoperative useful hearing (defined as class I or II of the Gardner-Robertson classification system) and underwent hearing-preservation VSS with the use of the MCT. Mapping was considered successful when it was possible to detect and trace the cochlear nerve. RESULTS Mapping of the cochlear nerve was successful in 13 of 18 patients (72.2%), and useful hearing was preserved in 11 patients (61.1%). Among 8 patients with large tumors (Koos grade 3 or 4), the rate of successful mapping was 62.5% (5 patients). The rate of hearing preservation in patients with large tumors was 50% (4 patients). CONCLUSIONS In addition to microsurgical presumption of the arrangement of each nerve, frequent probing on and around an unidentified nerve and comparison of each waveform are advisable with the use of both more sensitive monopolar and more location-specific bipolar MCT. MCT proved to be useful in cochlear nerve mapping and may consequently be helpful in hearing preservation. The authors discuss some limitations and problems with this device.

  3. The cochlear nerve canal and internal auditory canal in children with normal cochlea but cochlear nerve deficiency

    International Nuclear Information System (INIS)

    Yan, Fei; Li, Jianhong; Xian, Junfang; Wang, Zhenchang; Mo, Lingyan

    2013-01-01

    Background: There is an increasing frequency of requests for cochlear implantation (CI) in deaf children and more detailed image information is necessary for selecting appropriate candidates. Cochlear nerve deficiency (CND) is a contraindication to CI. Magnetic resonance imaging (MRI) has been used to evaluate the integrity of the cochlear nerve. The abnormalities of the cochlear nerve canal (CNC) and internal auditory canal (IAC) have been reported to be associated with CND. Purpose: To correlate CNC manifestation, size, and IAC diameter on high-resolution CT (HRCT) with CND diagnosed by MRI in children. Material and Methods: HRCT images from 35 sensorineurally deaf children who had normal cochlea but bilateral or unilateral CND diagnosed by MRI were studied retrospectively. The CNC and IAC manifestation and size were assessed and correlated with CND. Results: CND was diagnosed by MRI in 54/70 ears (77.1%). Thirty-two ears had an absent cochlear nerve (59.3%), while 22 ears had a small cochlear nerve (40.7%). The CNC diameter was 2.0 mm in 11 ears (20.4%). The IAC diameter was 3.0 mm in 29 ears (53.7%). Conclusion: The hypoplastic CNC might be more highly indicative of CND than that of a narrow IAC

  4. The cochlear nerve canal and internal auditory canal in children with normal cochlea but cochlear nerve deficiency

    Energy Technology Data Exchange (ETDEWEB)

    Yan, Fei; Li, Jianhong; Xian, Junfang; Wang, Zhenchang [Dept. of Radiology, Beijing Tongren Hospital, Capital Medical Univ., Beijing (China)], e-mail: cjr.wzhch@vip.163.com; Mo, Lingyan [Dept. of Otorhinolaryngology, Beijing Tongren Hospital, Capital Medical Univ., Beijing (China)

    2013-04-15

    Background: There is an increasing frequency of requests for cochlear implantation (CI) in deaf children and more detailed image information is necessary for selecting appropriate candidates. Cochlear nerve deficiency (CND) is a contraindication to CI. Magnetic resonance imaging (MRI) has been used to evaluate the integrity of the cochlear nerve. The abnormalities of the cochlear nerve canal (CNC) and internal auditory canal (IAC) have been reported to be associated with CND. Purpose: To correlate CNC manifestation, size, and IAC diameter on high-resolution CT (HRCT) with CND diagnosed by MRI in children. Material and Methods: HRCT images from 35 sensorineurally deaf children who had normal cochlea but bilateral or unilateral CND diagnosed by MRI were studied retrospectively. The CNC and IAC manifestation and size were assessed and correlated with CND. Results: CND was diagnosed by MRI in 54/70 ears (77.1%). Thirty-two ears had an absent cochlear nerve (59.3%), while 22 ears had a small cochlear nerve (40.7%). The CNC diameter was <1.5 mm in 36 ears (66.7%). The CNC diameter ranged between 1.5 and 2.0 mm in seven ears (13.0%) and was >2.0 mm in 11 ears (20.4%). The IAC diameter was <3.0 mm in 25 ears (46.3%) and >3.0 mm in 29 ears (53.7%). Conclusion: The hypoplastic CNC might be more highly indicative of CND than that of a narrow IAC.

  5. Retrolabyrinthine approach for cochlear nerve preservation in neurofibromatosis type 2 and simultaneous cochlear implantation

    Directory of Open Access Journals (Sweden)

    Bento, Ricardo Ferreira

    2014-01-01

    Full Text Available Introduction: Few cases of cochlear implantation (CI in neurofibromatosis type 2 (NF2 patients had been reported in the literature. The approaches described were translabyrinthine, retrosigmoid or middle cranial fossa. Objectives: To describe a case of a NF2- deafened-patient who underwent to vestibular schwannoma resection via RLA with cochlear nerve preservation and CI through the round window, at the same surgical time. Resumed Report: A 36-year-old woman with severe bilateral hearing loss due to NF2 was submitted to vestibular schwannoma resection and simultaneous CI. Functional assessment of cochlear nerve was performed by electrical promontory stimulation. Complete tumor removal was accomplishment via RLA with anatomic and functional cochlear and facial nerve preservation. Cochlear electrode array was partially inserted via round window. Sound field hearing threshold improvement was achieved. Mean tonal threshold was 46.2 dB HL. The patient could only detect environmental sounds and human voice but cannot discriminate vowels, words nor do sentences at 2 years of follow-up. Conclusion: Cochlear implantation is a feasible auditory restoration option in NF2 when cochlear anatomic and functional nerve preservation is achieved. The RLA is adequate for this purpose and features as an option for hearing preservation in NF2 patients.

  6. Anomalous facial nerve canal with cochlear malformations.

    Science.gov (United States)

    Romo, L V; Curtin, H D

    2001-05-01

    Anteromedial "migration" of the first segment of the facial nerve canal has been previously identified in a patient with a non-Mondini-type cochlear malformation. In this study, several patients with the same facial nerve canal anomaly were reviewed to assess for the association and type of cochlear malformation. CT scans of the temporal bone of 15 patients with anteromedial migration of the first segment of the facial nerve canal were collected from routine departmental examinations. In seven patients, the anomalous course was bilateral, for a total of 22 cases. The migration was graded relative to normal as either mild/moderate or pronounced. The cochlea in each of these cases was examined for the presence and size of the basilar, second, and apical turns. The turns were either absent, small, normal, or enlarged. The CT scans of five patients with eight Mondini malformations were examined for comparison. The degree of the facial nerve migration was pronounced in nine cases and mild/moderate in 13. All 22 of these cases had associated cochlear abnormalities of the non-Mondini variety. These included common cavity anomalies with lack of definition between the cochlea and vestibule (five cases), cochleae with enlarged basilar turns and absent second or third turns (five cases), and cochleae with small or normal basilar turns with small or absent second or third turns (12 cases). None of the patients with Mondini-type cochlear malformations had anteromedial migration of the facial nerve canal. Anteromedial migration of the facial nerve canal occurs in association with some cochlear malformations. It did not occur in association with the Mondini malformations. A cochlea with a Mondini malformation, being similar in size to a normal cochlea, may physically prohibit such a deviation in course.

  7. The Role of MRI in Diagnosing Neurovascular Compression of the Cochlear Nerve Resulting in Typewriter Tinnitus.

    Science.gov (United States)

    Bae, Y J; Jeon, Y J; Choi, B S; Koo, J-W; Song, J-J

    2017-06-01

    Typewriter tinnitus, a symptom characterized by paroxysmal attacks of staccato sounds, has been thought to be caused by neurovascular compression of the cochlear nerve, but the correlation between radiologic evidence of neurovascular compression of the cochlear nerve and symptom presentation has not been thoroughly investigated. The purpose of this study was to examine whether radiologic evidence of neurovascular compression of the cochlear nerve is pathognomonic in typewriter tinnitus. Fifteen carbamazepine-responding patients with typewriter tinnitus and 8 control subjects were evaluated with a 3D T2-weighted volume isotropic turbo spin-echo acquisition sequence. Groups 1 (16 symptomatic sides), 2 (14 asymptomatic sides), and 3 (16 control sides) were compared with regard to the anatomic relation between the vascular loop and the internal auditory canal and the presence of neurovascular compression of the cochlear nerve with/without angulation/indentation. The anatomic location of the vascular loop was not significantly different among the 3 groups (all, P > .05). Meanwhile, neurovascular compression of the cochlear nerve on MR imaging was significantly higher in group 1 than in group 3 ( P = .032). However, considerable false-positive (no symptoms with neurovascular compression of the cochlear nerve on MR imaging) and false-negative (typewriter tinnitus without demonstrable neurovascular compression of the cochlear nerve) findings were also observed. Neurovascular compression of the cochlear nerve was more frequently detected on the symptomatic side of patients with typewriter tinnitus compared with the asymptomatic side of these patients or on both sides of control subjects on MR imaging. However, considering false-positive and false-negative findings, meticulous history-taking and the response to the initial carbamazepine trial should be regarded as more reliable diagnostic clues than radiologic evidence of neurovascular compression of the cochlear nerve.

  8. The significance of a hypoplastic bony canal for the cochlear nerve in patients with sensorineural hearing loss: CT and MRI findings

    International Nuclear Information System (INIS)

    Choi, Yoon Jung; Park, Sang Yoo; Kim, Myung Soon; Sung, Ki Jun

    2004-01-01

    The purpose of this study is to evaluate the significance of the hypoplastic canal for the cochlear nerve in patients with sensorineural hearing loss (SNHL) and the relationship between the hypoplastic bony canal and aplasia or hypoplasia of the cochlear nerve. A retrospective review of high resolution temporal CT(HRCT) and MRI findings was conducted. The narrow bony canal of the cochlear nerve and the relative size of the internal auditory canal were correlated with the cochlear nerve deficiency on MRI. The comparative size of the component nerves (facial, cochlear, superior vestibular, inferior vestibular nerve), and the relative size of the internal auditory canal and the bony canal of the cochlear nerve were measured. The clinical history and the results of the clinical examination were reviewed for each patient. High resolution MRI showed aplasia of the common vestibulocochlear nerve in one patient and a deficiency of the cochlear nerve in 9 patients. These abnormalities occurred in association with a prominent narrowing of the canal for the cochlear nerve and a stenosis of the internal auditory canal, which was observed on temporal bone CT in 9 patients with congenital SNHL. Three patients had normal IAC, despite the presence of a hypoplastic cochlear nerve on the side on which they had SNHL. In one patient, the narrowing of the canal for the cochlear nerve and internal auditory canal were not found to be associated with acquired SNHL. The hypoplastic bony canal for the cochlear nerve might be more highly indicative of congenital cochlear nerve deficiency than that of the narrow internal auditory canal, and the position of the crista falciformis should also be carefully

  9. The significance of a hypoplastic bony canal for the cochlear nerve in patients with sensorineural hearing loss: CT and MRI findings

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Yoon Jung; Park, Sang Yoo; Kim, Myung Soon; Sung, Ki Jun [College of Medicine, Yonsei Univ., Wonju (Korea, Republic of)

    2004-04-01

    The purpose of this study is to evaluate the significance of the hypoplastic canal for the cochlear nerve in patients with sensorineural hearing loss (SNHL) and the relationship between the hypoplastic bony canal and aplasia or hypoplasia of the cochlear nerve. A retrospective review of high resolution temporal CT(HRCT) and MRI findings was conducted. The narrow bony canal of the cochlear nerve and the relative size of the internal auditory canal were correlated with the cochlear nerve deficiency on MRI. The comparative size of the component nerves (facial, cochlear, superior vestibular, inferior vestibular nerve), and the relative size of the internal auditory canal and the bony canal of the cochlear nerve were measured. The clinical history and the results of the clinical examination were reviewed for each patient. High resolution MRI showed aplasia of the common vestibulocochlear nerve in one patient and a deficiency of the cochlear nerve in 9 patients. These abnormalities occurred in association with a prominent narrowing of the canal for the cochlear nerve and a stenosis of the internal auditory canal, which was observed on temporal bone CT in 9 patients with congenital SNHL. Three patients had normal IAC, despite the presence of a hypoplastic cochlear nerve on the side on which they had SNHL. In one patient, the narrowing of the canal for the cochlear nerve and internal auditory canal were not found to be associated with acquired SNHL. The hypoplastic bony canal for the cochlear nerve might be more highly indicative of congenital cochlear nerve deficiency than that of the narrow internal auditory canal, and the position of the crista falciformis should also be carefully.

  10. Neurophysiologic intraoperative monitoring of the vestibulocochlear nerve.

    Science.gov (United States)

    Simon, Mirela V

    2011-12-01

    Neurosurgical procedures involving the skull base and structures within can pose a significant risk of damage to the brain stem and cranial nerves. This can have life-threatening consequences and/or result in devastating neurologic deficits. Over the past decade, intraoperative neurophysiology has significantly evolved and currently offers a great tool for live monitoring of the integrity of nervous structures. Thus, dysfunction can be identified early and prompt modification of the surgical management or operating conditions, leads to avoidance of permanent structural damage.Along these lines, the vestibulocochlear nerve (CN VIII) and, to a greater extent, the auditory pathways as they pass through the brain stem are especially at risk during cerebelopontine angle (CPA), posterior/middle fossa, or brain stem surgery. CN VIII can be damaged by several mechanisms, from vascular compromise to mechanical injury by stretch, compression, dissection, and heat injury. Additionally, cochlea itself can be significantly damaged during temporal bone drilling, by noise, mechanical destruction, or infarction, and because of rupture, occlusion, or vasospasm of the internal auditory artery.CN VIII monitoring can be successfully achieved by live recording of the function of one of its parts, the cochlear or auditory nerve (AN), using the brain stem auditory evoked potentials (BAEPs), electrocochleography (ECochG), and compound nerve action potentials (CNAPs) of the cochlear nerve.This is a review of these techniques, their principle, applications, methodology, interpretation of the evoked responses, and their change from baseline, within the context of surgical and anesthesia environments, and finally the appropriate management of these changes.

  11. Microsurgical Decompression of the Cochlear Nerve to Treat Disabling Tinnitus via an Endoscope-Assisted Retrosigmoid Approach: The Padua Experience.

    Science.gov (United States)

    Di Stadio, Arianna; Colangeli, Roberta; Dipietro, Laura; Martini, Alessandro; Parrino, Daniela; Nardello, Ennio; D'Avella, Domenico; Zanoletti, Elisabetta

    2018-05-01

    The use of surgical cochlear nerve decompression is controversial. This study aimed at investigating the safety and validity of microsurgical decompression via an endoscope-assisted retrosigmoid approach to treat tinnitus in patients with neurovascular compression of the cochlear nerve. Three patients with disabling tinnitus resulting from a loop in the internal auditory canal were evaluated with magnetic resonance imaging and tests of pure tone auditory, tinnitus, and auditory brain response (ABR) to identify the features of the cochlear nerve involvement. We observed a loop with a caliber greater than 0.8 mm in all patients. Patients were treated via an endoscope-assisted retrosigmoid microsurgical decompression. After surgery, none of the patients reported short-term or long-term complications. After surgery, tinnitus resolved immediately in 2 patients, whereas in the other patient symptoms persisted although they improved; in all patients, hearing was preserved and ABR improved. Microsurgical decompression via endoscope-assisted retrosigmoid approach is a promising, safe, and valid procedure for treating tinnitus caused by cochlear nerve compression. This procedure should be considered in patients with disabling tinnitus who have altered ABR and a loop that has a caliber greater than 0.8 mm and is in contact with the cochlear nerve. Copyright © 2018 Elsevier Inc. All rights reserved.

  12. Facial nerve stimulation outcomes after cochlear implantation with cochlear-facial dehiscence

    Directory of Open Access Journals (Sweden)

    Christina H. Fang, MD

    2017-06-01

    Conclusion: Cochlear-facial dehiscence can predispose patients to post-implant FNS. Prior temporal bone irradiation may carry a higher risk of FNS. We recommend scrutiny for CFD in CTs of CI candidates and appropriate risk counseling for FNS if CFD is discovered and more frequent monitoring for FNS by audiology.

  13. Computed tomographic features of the bony canal of the cochlear nerve in pediatric patients with unilateral sensorineural hearing loss

    International Nuclear Information System (INIS)

    Kono, Tatsuo

    2008-01-01

    The aim of this study was to evaluate the diameters of the various bony canals of the inner ear in patients with sensorineural hearing loss (SNHL) and establish criteria for detecting hypoplasia of the bony canal of the cochlear nerve. Measurements obtained in 118 patients without inner ear malformations among 160 patients with unilateral SNHL were analyzed. The diameters of the internal auditory canal and the bony canals of the cochlear, vestibular, and facial nerves were measured on transverse or coronal computed tomographic images. Mean values (±standard deviation (SD)) were compared between the affected and unaffected ears, and statistical analysis was done. The diameter of the bony canal of the cochlear nerve was significantly smaller in affected ears than in unaffected ears (P<0.01). The affected ears could be divided into groups with (72 ears) and without (46 ears) bony canal stenosis. Most (60%) of the patients with unilateral SNHL showed a significant difference in the diameters of the bony canals of the cochlear nerve between the affected and unaffected sides; moreover, the mean value was significantly smaller in affected ears. The diameter of <1.7 mm on transverse images or <1.8 mm on coronal images suggests hypoplasia. (author)

  14. Analysis of electrically evoked compound action potential of the auditory nerve in children with bilateral cochlear implants.

    Science.gov (United States)

    Caldas, Fernanda Ferreira; Cardoso, Carolina Costa; Barreto, Monique Antunes de Souza Chelminski; Teixeira, Marina Santos; Hilgenberg, Anacléia Melo da Silva; Serra, Lucieny Silva Martins; Bahmad Junior, Fayez

    2016-01-01

    The cochlear implant device has the capacity to measure the electrically evoked compound action potential of the auditory nerve. The neural response telemetry is used in order to measure the electrically evoked compound action potential of the auditory nerve. To analyze the electrically evoked compound action potential, through the neural response telemetry, in children with bilateral cochlear implants. This is an analytical, prospective, longitudinal, historical cohort study. Six children, aged 1-4 years, with bilateral cochlear implant were assessed at five different intervals during their first year of cochlear implant use. There were significant differences in follow-up time (p=0.0082) and electrode position (p=0.0019) in the T-NRT measure. There was a significant difference in the interaction between time of follow-up and electrode position (p=0.0143) when measuring the N1-P1 wave amplitude between the three electrodes at each time of follow-up. The electrically evoked compound action potential measurement using neural response telemetry in children with bilateral cochlear implants during the first year of follow-up was effective in demonstrating the synchronized bilateral development of the peripheral auditory pathways in the studied population. Copyright © 2015 Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial. Published by Elsevier Editora Ltda. All rights reserved.

  15. Improved imaging of cochlear nerve hypoplasia using a 3-Tesla variable flip-angle turbo spin-echo sequence and a 7-cm surface coil.

    Science.gov (United States)

    Giesemann, Anja M; Raab, Peter; Lyutenski, Stefan; Dettmer, Sabine; Bültmann, Eva; Frömke, Cornelia; Lenarz, Thomas; Lanfermann, Heinrich; Goetz, Friedrich

    2014-03-01

    Magnetic resonance imaging of the temporal bone has an important role in decision making with regard to cochlea implantation, especially in children with cochlear nerve deficiency. The purpose of this study was to evaluate the usefulness of the combination of an advanced high-resolution T2-weighted sequence with a surface coil in a 3-Tesla magnetic resonance imaging scanner in cases of suspected cochlear nerve aplasia. Prospective study. Seven patients with cochlear nerve hypoplasia or aplasia were prospectively examined using a high-resolution three-dimensional variable flip-angle turbo spin-echo sequence using a surface coil, and the images were compared with the same sequence in standard resolution using a standard head coil. Three neuroradiologists evaluated the magnetic resonance images independently, rating the visibility of the nerves in diagnosing hypoplasia or aplasia. Eight ears in seven patients with hypoplasia or aplasia of the cochlear nerve were examined. The average age was 2.7 years (range, 9 months-5 years). Seven ears had accompanying malformations. The inter-rater reliability in diagnosing hypoplasia or aplasia was greater using the high-resolution three-dimensional variable flip-angle turbo spin-echo sequence (fixed-marginal kappa: 0.64) than with the same sequence in lower resolution (fixed-marginal kappa: 0.06). Examining cases of suspected cochlear nerve aplasia using the high-resolution three-dimensional variable flip-angle turbo spin-echo sequence in combination with a surface coil shows significant improvement over standard methods. © 2013 The American Laryngological, Rhinological and Otological Society, Inc.

  16. Intraoperative observation of changes in cochlear nerve action potentials during exposure to electromagnetic fields generated by mobile phones.

    Science.gov (United States)

    Colletti, Vittorio; Mandalà, Marco; Manganotti, Paolo; Ramat, Stefano; Sacchetto, Luca; Colletti, Liliana

    2011-07-01

    The rapid spread of devices generating electromagnetic fields (EMF) has raised concerns as to the possible effects of this technology on humans. The auditory system is the neural organ most frequently and directly exposed to electromagnetic activity owing to the daily use of mobile phones. In recent publications, a possible correlation between mobile phone usage and central nervous system tumours has been detected. Very recently a deterioration in otoacoustic emissions and in the auditory middle latency responses after intensive and long-term magnetic field exposure in humans has been demonstrated. To determine with objective observations if exposure to mobile phone EMF affects acoustically evoked cochlear nerve compound action potentials, seven patients suffering from Ménière's disease and undergoing retrosigmoid vestibular neurectomy were exposed to the effects of mobile phone placed over the craniotomy for 5 min. All patients showed a substantial decrease in amplitude and a significant increase in latency of cochlear nerve compound action potentials during the 5 min of exposure to EMF. These changes lasted for a period of around 5 min after exposure. The possibility that EMF can produce relatively long-lasting effects on cochlear nerve conduction is discussed and analysed in light of contrasting previous literature obtained under non-surgical conditions. Limitations of this novel approach, including the effects of the anaesthetics, craniotomy and surgical procedure, are presented in detail.

  17. Intraoperative cranial nerve monitoring.

    Science.gov (United States)

    Harper, C Michel

    2004-03-01

    The purpose of intraoperative monitoring is to preserve function and prevent injury to the nervous system at a time when clinical examination is not possible. Cranial nerves are delicate structures and are susceptible to damage by mechanical trauma or ischemia during intracranial and extracranial surgery. A number of reliable electrodiagnostic techniques, including nerve conduction studies, electromyography, and the recording of evoked potentials have been adapted to the study of cranial nerve function during surgery. A growing body of evidence supports the utility of intraoperative monitoring of cranial nerve nerves during selected surgical procedures.

  18. Importance of cochlear health for implant function.

    Science.gov (United States)

    Pfingst, Bryan E; Zhou, Ning; Colesa, Deborah J; Watts, Melissa M; Strahl, Stefan B; Garadat, Soha N; Schvartz-Leyzac, Kara C; Budenz, Cameron L; Raphael, Yehoash; Zwolan, Teresa A

    2015-04-01

    Amazing progress has been made in providing useful hearing to hearing-impaired individuals using cochlear implants, but challenges remain. One such challenge is understanding the effects of partial degeneration of the auditory nerve, the target of cochlear implant stimulation. Here we review studies from our human and animal laboratories aimed at characterizing the health of the implanted cochlea and the auditory nerve. We use the data on cochlear and neural health to guide rehabilitation strategies. The data also motivate the development of tissue-engineering procedures to preserve or build a healthy cochlea and improve performance obtained by cochlear implant recipients or eventually replace the need for a cochlear implant. This article is part of a Special Issue entitled . Copyright © 2014 Elsevier B.V. All rights reserved.

  19. Congenital malformations of the ear and cochlear implantation in children: review and temporal bone report of common cavity.

    Science.gov (United States)

    Graham, J M; Phelps, P D; Michaels, L

    2000-01-01

    The objective of this review is to analyze aspects of congenital malformation of the ear in relation to cochlear implantation in children. Having briefly described the in utero development of the ear and the classification of types of external, middle and inner ear malformation, five practical aspects of these malformations are discussed. It seems likely that the combination of bilateral profound sensorineural deafness with bilateral microtia severe enough to make a surgical approach to the cochlea difficult will be extremely uncommon. No such cases have been reported, although Klippel-Feil deformity seems the syndrome most likely to produce this set of circumstances. Abnormalities in the intratympanic course of the facial nerve have been associated with cochlear malformation, emphasizing the benefit of intra-operative facial nerve monitoring, and a technique suggested for safely avoiding an abnormally placed nerve. Fistulae of cerebrospinal fluid (CSF) and perilymph can complicate surgery and are relatively common in common cavity and Mondini malformations. Strategies for facilitating surgery in the presence of 'gushers', for measuring the pressure of a gusher and for placement of the cochlear implant electrode array are reviewed, with reports of fluctuating levels of electric current when implants lie in dysplastic cochleas. The relationship of implant performance to VIIIth nerve tissue in malformed cochleas is discussed, with a description of the histological findings in a common cavity cochlea. Techniques for identifying the absence of the cochlear nerve are reviewed. Stimulation of the facial nerve by cochlear implants has been described in cases of congenital malformation of the labyrinth but is relatively uncommon. Case reports of the benefit received by implanted children with congenital cochlear malformation have appeared since 1988. Most cases reported have not yet been followed for long enough to establish a clear picture of the outcome following

  20. Cochlear implantation in patients with bilateral cochlear trauma.

    Science.gov (United States)

    Serin, Gediz Murat; Derinsu, Ufuk; Sari, Murat; Gergin, Ozgül; Ciprut, Ayça; Akdaş, Ferda; Batman, Cağlar

    2010-01-01

    Temporal bone fracture, which involves the otic capsule, can lead to complete loss of auditory and vestibular functions, whereas the patients without fractures may experience profound sensorineural hearing loss due to cochlear concussion. Cochlear implant is indicated in profound sensorineural hearing loss due to cochlear trauma but who still have an intact auditory nerve. This is a retrospective review study. We report 5 cases of postlingually deafened patients caused by cochlear trauma, who underwent cochlear implantation. Preoperative and postoperative hearing performance will be presented. These patients are cochlear implanted after the cochlear trauma in our department between 2001 and 2006. All patients performed very well with their implants, obtained open-set speech understanding. They all became good telephone users after implantation. Their performance in speech understanding was comparable to standard postlingual adult patients implanted. Cochlear implantation is an effective aural rehabilitation in profound sensorineural hearing loss caused by temporal bone trauma. Preoperative temporal bone computed tomography, magnetic resonance imaging, and promontorium stimulation testing are necessary to make decision for the surgery and to determine the side to be implanted. Surgery could be challenging and complicated because of anatomical irregularity. Moreover, fibrosis and partial or total ossification within the cochlea must be expected. Copyright 2010. Published by Elsevier Inc.

  1. Follow-up of cochlear implant use in patients who developed bacterial meningitis following cochlear implantation.

    Science.gov (United States)

    Mancini, Patrizia; D'Elia, Chiara; Bosco, Ersilia; De Seta, Elio; Panebianco, Valeria; Vergari, Valeria; Filipo, Roberto

    2008-08-01

    The present study is a long-term follow-up of speech perception outcomes and cochlear implant use in three cases of meningitis that occurred after cochlear implantation. Case series study. Study was performed on three children implanted with different models of Clarion devices, two of them with positioner. Recognition and comprehension were assessed via the Italian adaptation of GASP (TAP) test, and phonetically balanced bi-syllabic words in open-set. High resolution computed tomography scan acquisition was performed to obtain axial coronal and oblique multiplanar reconstructions of the cochlea. Two patients were affected by enlarged cochlear acqueduct and Mondini malformation the first carrying positioner. One patient had a normal cochlea, and the positioner could have been the main cause of bacterial spread. As a consequence of meningitis the child with normal cochlea and the other with enlarged vestibular acqueduct developed cochlear ossification, increased M-level and worsening of hearing outcomes. The child with Mondini malformation developed facial nerve stimulation. Contralateral implantation was performed in the first two patients. Bacterial meningitis occurring after cochlear implantation may induce cochlear ossification, facial nerve stimulation, and permanent or temporary loss of implant use. Planned follow-up with high resolution computed tomography and evaluation of M-levels could be useful prognostic tools in the management of these patients.

  2. [Cochlear implantation through the middle fossa approach].

    Science.gov (United States)

    Szyfter, W; Colletti, V; Pruszewicz, A; Kopeć, T; Szymiec, E; Kawczyński, M; Karlik, M

    2001-01-01

    The inner part of cochlear implant is inserted into inner ear during surgery through mastoid and middle ear. It is a classical method, used in the majority cochlear centers in the world. This is not a suitable method in case of chronic otitis media and middle ear malformation. In these cases Colletti proposed the middle fossa approach and cochlear implant insertion omitting middle ear structures. In patient with bilateral chronic otitis media underwent a few ears operations without obtaining dry postoperative cavity. Cochlear implantation through the middle fossa approach was performed in this patient. The bone fenster was cut, temporal lobe was bent and petrosus pyramid upper surface was exposed. When the superficial petrosal greater nerve, facial nerve and arcuate eminence were localised, the cochlear was open in the basal turn and electrode were inserted. The patient achieves good results in the postoperative speech rehabilitation. It confirmed Colletti tesis that deeper electrode insertion in the cochlear implantation through the middle fossa approach enable use of low and middle frequencies, which are very important in speech understanding.

  3. Cell-type specific short-term plasticity at auditory nerve synapses controls feed-forward inhibition in the dorsal cochlear nucleus

    Directory of Open Access Journals (Sweden)

    Miloslav eSedlacek

    2014-07-01

    Full Text Available Feedforward inhibition represents a powerful mechanism by which control of the timing and fidelity of action potentials in local synaptic circuits of various brain regions is achieved. In the cochlear nucleus, the auditory nerve provides excitation to both principal neurons and inhibitory interneurons. Here, we investigated the synaptic circuit associated with fusiform cells (FCs, principal neurons of the dorsal cochlear nucleus (DCN that receive excitation from auditory nerve fibers and inhibition from tuberculoventral cells (TVCs on their basal dendrites in the deep layer of DCN. Despite the importance of these inputs in regulating fusiform cell firing behavior, the mechanisms determining the balance of excitation and feed-forward inhibition in this circuit are not well understood. Therefore, we examined the timing and plasticity of auditory nerve driven feed-forward inhibition (FFI onto FCs. We find that in some FCs, excitatory and inhibitory components of feed-forward inhibition had the same stimulation thresholds indicating they could be triggered by activation of the same fibers. In other FCs, excitation and inhibition exhibit different stimulus thresholds, suggesting FCs and TVCs might be activated by different sets of fibers. In addition we find that during repetitive activation, synapses formed by the auditory nerve onto TVCs and FCs exhibit distinct modes of short-term plasticity. Feed-forward inhibitory post-synaptic currents (IPSCs in FCs exhibit short-term depression because of prominent synaptic depression at the auditory nerve-TVC synapse. Depression of this feedforward inhibitory input causes a shift in the balance of fusiform cell synaptic input towards greater excitation and suggests that fusiform cell spike output will be enhanced by physiological patterns of auditory nerve activity.

  4. Cell-type specific short-term plasticity at auditory nerve synapses controls feed-forward inhibition in the dorsal cochlear nucleus.

    Science.gov (United States)

    Sedlacek, Miloslav; Brenowitz, Stephan D

    2014-01-01

    Feed-forward inhibition (FFI) represents a powerful mechanism by which control of the timing and fidelity of action potentials in local synaptic circuits of various brain regions is achieved. In the cochlear nucleus, the auditory nerve provides excitation to both principal neurons and inhibitory interneurons. Here, we investigated the synaptic circuit associated with fusiform cells (FCs), principal neurons of the dorsal cochlear nucleus (DCN) that receive excitation from auditory nerve fibers and inhibition from tuberculoventral cells (TVCs) on their basal dendrites in the deep layer of DCN. Despite the importance of these inputs in regulating fusiform cell firing behavior, the mechanisms determining the balance of excitation and FFI in this circuit are not well understood. Therefore, we examined the timing and plasticity of auditory nerve driven FFI onto FCs. We find that in some FCs, excitatory and inhibitory components of FFI had the same stimulation thresholds indicating they could be triggered by activation of the same fibers. In other FCs, excitation and inhibition exhibit different stimulus thresholds, suggesting FCs and TVCs might be activated by different sets of fibers. In addition, we find that during repetitive activation, synapses formed by the auditory nerve onto TVCs and FCs exhibit distinct modes of short-term plasticity. Feed-forward inhibitory post-synaptic currents (IPSCs) in FCs exhibit short-term depression because of prominent synaptic depression at the auditory nerve-TVC synapse. Depression of this feedforward inhibitory input causes a shift in the balance of fusiform cell synaptic input towards greater excitation and suggests that fusiform cell spike output will be enhanced by physiological patterns of auditory nerve activity.

  5. Cochlear implant: what the radiologist should know

    Directory of Open Access Journals (Sweden)

    Natalia Delage Gomes

    2013-06-01

    Full Text Available Cochlear implant is the method of choice in the treatment of deep sensorineural hypoacusis, particularly in patients where conventional amplification devices do not imply noticeable clinical improvement. Imaging findings are crucial in the indication or contraindication for such surgical procedure. In the assessment of the temporal bone, radiologists should be familiar with relative or absolute contraindication factors, as well as with factors that might significantly complicate the implantation. Some criteria such as cochlear nerve aplasia, labyrinthine and/or cochlear aplasia are still considered as absolute contraindications, in spite of studies bringing such criteria into question. Cochlear dysplasias constitute relative contraindications, among them labyrinthitis ossificans is highlighted. Other alterations may be mentioned as complicating agents in the temporal bone assessment, namely, hypoplasia of the mastoid process, aberrant facial nerve, otomastoiditis, otosclerosis, dehiscent jugular bulb, enlarged endolymphatic duct and sac. The experienced radiologist assumes an important role in the evaluation of this condition.

  6. Cochlear implant: what the radiologist should know

    International Nuclear Information System (INIS)

    Gomes, Natalia Delage; Couto, Caroline Laurita Batista; Gaiotti, Juliana Oggioni; Costa, Ana Maria Doffemond; Ribeiro, Marcelo Almeida; Diniz, Renata Lopes Furletti Caldeira

    2013-01-01

    Cochlear implant is the method of choice in the treatment of deep sensorineural hypoacusis, particularly in patients where conventional amplification devices do not imply noticeable clinical improvement. Imaging findings are crucial in the indication or contraindication for such surgical procedure. In the assessment of the temporal bone, radiologists should be familiar with relative or absolute contraindication factors, as well as with factors that might significantly complicate the implantation. Some criteria such as cochlear nerve aplasia, labyrinthine and/or cochlear aplasia are still considered as absolute contraindications, in spite of studies bringing such criteria into question. Cochlear dysplasias constitute relative contraindications, among them labyrinthitis ossificans is highlighted. Other alterations may be mentioned as complicating agents in the temporal bone assessment, namely, hypoplasia of the mastoid process, aberrant facial nerve, otomastoiditis, otosclerosis, dehiscent jugular bulb, enlarged endolymphatic duct and sac. The experienced radiologist assumes an important role in the evaluation of this condition. (author)

  7. Visualization of spiral ganglion neurites within the scala tympani with a cochlear implant in situ.

    Science.gov (United States)

    Chikar, Jennifer A; Batts, Shelley A; Pfingst, Bryan E; Raphael, Yehoash

    2009-05-15

    Current cochlear histology methods do not allow in situ processing of cochlear implants. The metal components of the implant preclude standard embedding and mid-modiolar sectioning, and whole mounts do not have the spatial resolution needed to view the implant within the scala tympani. One focus of recent auditory research is the regeneration of structures within the cochlea, particularly the ganglion cells and their processes, and there are multiple potential benefits to cochlear implant users from this work. To facilitate experimental investigations of auditory nerve regeneration performed in conjunction with cochlear implantation, it is critical to visualize the cochlear tissue and the implant together to determine if the nerve has made contact with the implant. This paper presents a novel histological technique that enables simultaneous visualization of the in situ cochlear implant and neurofilament-labeled nerve processes within the scala tympani, and the spatial relationship between them.

  8. STEREOLOGICAL ANALYSIS OF THE COCHLEAR NUCLEI OF MONKEY (MACACA FASCICULARIS AFTER DEAFFERENTATION

    Directory of Open Access Journals (Sweden)

    Ana M Insausti

    2011-05-01

    Full Text Available The cochlear nuclei (CN in the brainstem receive the input signals from the inner ear through the cochlear nerve, and transmit these signals to higher auditory centres. A variety of lesions of the cochlear nerve cause deafness. As reported in the literature, artificial removal of auditive input, or 'deafferentation', induces structural alterations in the CN. The purpose of this study was to estimate a number of relevant stereological parameters of the CN in control and deafferented Macaca fascicularis monkeys.

  9. Probabilistic Tractography of the Cranial Nerves in Vestibular Schwannoma.

    Science.gov (United States)

    Zolal, Amir; Juratli, Tareq A; Podlesek, Dino; Rieger, Bernhard; Kitzler, Hagen H; Linn, Jennifer; Schackert, Gabriele; Sobottka, Stephan B

    2017-11-01

    Multiple recent studies have reported on diffusion tensor-based fiber tracking of cranial nerves in vestibular schwannoma, with conflicting results as to the accuracy of the method and the occurrence of cochlear nerve depiction. Probabilistic nontensor-based tractography might offer advantages in terms of better extraction of directional information from the underlying data in cranial nerves, which are of subvoxel size. Twenty-one patients with large vestibular schwannomas were recruited. The probabilistic tracking was run preoperatively and the position of the potential depictions of the facial and cochlear nerves was estimated postoperatively by 3 independent observers in a blinded fashion. The true position of the nerve was determined intraoperatively by the surgeon. Thereafter, the imaging-based estimated position was compared with the intraoperatively determined position. Tumor size, cystic appearance, and postoperative House-Brackmann score were analyzed with regard to the accuracy of the depiction of the nerves. The probabilistic tracking showed a connection that correlated to the position of the facial nerve in 81% of the cases and to the position of the cochlear nerve in 33% of the cases. Altogether, the resulting depiction did not correspond to the intraoperative position of any of the nerves in 3 cases. In a majority of cases, the position of the facial nerve, but not of the cochlear nerve, could be estimated by evaluation of the probabilistic tracking results. However, false depictions not corresponding to any nerve do occur and cannot be discerned as such from the image only. Copyright © 2017 Elsevier Inc. All rights reserved.

  10. Intraoperative nerve monitoring in laryngotracheal surgery.

    Science.gov (United States)

    Bolufer, Sergio; Coves, María Dolores; Gálvez, Carlos; Villalona, Gustavo Adolfo

    Laryngotracheal surgery has an inherent risk of injury to the recurrent laryngeal nerves (RLN). These complications go from minor dysphonia to even bilateral vocal cord paralysis. The intraoperative neuromonitoring of the RLN was developed in the field of thyroid surgery, in order to preserve nerve and vocal cord function. However, tracheal surgery requires in-field intubation of the distal trachea, which limits the use of nerve monitoring using conventional endotracheal tube with surface electrodes. Given these challenges, we present an alternative method for nerve monitoring during laryngotracheal surgery through the insertion of electrodes within the endolaryngeal musculature by bilateral puncture. Copyright © 2016 AEC. Publicado por Elsevier España, S.L.U. All rights reserved.

  11. Progression of Unilateral Hearing Loss in Children With and Without Ipsilateral Cochlear Nerve Canal Stenosis: A Hazard Analysis.

    Science.gov (United States)

    Purcell, Patricia L; Shinn, Justin R; Coggeshall, Scott S; Phillips, Grace; Paladin, Angelisa; Sie, Kathleen C Y; Horn, David L

    2017-07-01

    To investigate the risk of hearing loss progression in each ear among children with unilateral hearing loss associated with ipsilateral bony cochlear nerve canal (BCNC) stenosis. Tertiary pediatric referral center. Children diagnosed with unilateral hearing loss who had undergone temporal bone computed tomography imaging and had at least 6 months of follow-up audiometric testing were identified from a prospective audiological database. Two pediatric radiologists blinded to affected ear evaluated imaging for temporal bone anomalies and measured bony cochlear canal width independently. All available audiograms were reviewed, and air conduction thresholds were documented. Progression of hearing loss was defined by a 10 dB increase in air conduction pure-tone average. One hundred twenty eight children met inclusion criteria. Of these, 54 (42%) had a temporal bone anomaly, and 22 (17%) had ipsilateral BCNC stenosis. At 12 months, rates of progression in the ipsilateral ear were as follows: 12% among those without a temporal bone anomaly, 13% among those with a temporal bone anomaly, and 17% among those with BCNC stenosis. Children with BCNC stenosis had a significantly greater risk of progression in their ipsilateral ear compared with children with no stenosis: hazard ratio (HR) 2.17, 95% confidence interval (CI) (1.01, 4.66), p value 0.046. When we compared children with BCNC stenosis to those with normal temporal bone imaging, we found that the children with stenosis had nearly two times greater risk estimate for progression, but this difference did not reach significance, HR 1.9, CI (0.8, 4.3), p = 0.1. No children with BCNC stenosis developed hearing loss in their contralateral year by 12 months of follow-up. Children with bony cochlear nerve canal stenosis may be at increased risk for progression in their ipsilateral ear. Audiometric and medical follow-up for these children should be considered.

  12. Chronic Conductive Hearing Loss Leads to Cochlear Degeneration.

    Science.gov (United States)

    Liberman, M Charles; Liberman, Leslie D; Maison, Stéphane F

    2015-01-01

    Synapses between cochlear nerve terminals and hair cells are the most vulnerable elements in the inner ear in both noise-induced and age-related hearing loss, and this neuropathy is exacerbated in the absence of efferent feedback from the olivocochlear bundle. If age-related loss is dominated by a lifetime of exposure to environmental sounds, reduction of acoustic drive to the inner ear might improve cochlear preservation throughout life. To test this, we removed the tympanic membrane unilaterally in one group of young adult mice, removed the olivocochlear bundle in another group and compared their cochlear function and innervation to age-matched controls one year later. Results showed that tympanic membrane removal, and the associated threshold elevation, was counterproductive: cochlear efferent innervation was dramatically reduced, especially the lateral olivocochlear terminals to the inner hair cell area, and there was a corresponding reduction in the number of cochlear nerve synapses. This loss led to a decrease in the amplitude of the suprathreshold cochlear neural responses. Similar results were seen in two cases with conductive hearing loss due to chronic otitis media. Outer hair cell death was increased only in ears lacking medial olivocochlear innervation following olivocochlear bundle cuts. Results suggest the novel ideas that 1) the olivocochlear efferent pathway has a dramatic use-dependent plasticity even in the adult ear and 2) a component of the lingering auditory processing disorder seen in humans after persistent middle-ear infections is cochlear in origin.

  13. Facial nerve mapping and monitoring in lymphatic malformation surgery.

    Science.gov (United States)

    Chiara, Jospeh; Kinney, Greg; Slimp, Jefferson; Lee, Gi Soo; Oliaei, Sepehr; Perkins, Jonathan A

    2009-10-01

    Establish the efficacy of preoperative facial nerve mapping and continuous intraoperative EMG monitoring in protecting the facial nerve during resection of cervicofacial lymphatic malformations. Retrospective study in which patients were clinically followed for at least 6 months postoperatively, and long-term outcome was evaluated. Patient demographics, lesion characteristics (i.e., size, stage, location) were recorded. Operative notes revealed surgical techniques, findings, and complications. Preoperative, short-/long-term postoperative facial nerve function was standardized using the House-Brackmann Classification. Mapping was done prior to incision by percutaneously stimulating the facial nerve and its branches and recording the motor responses. Intraoperative monitoring and mapping were accomplished using a four-channel, free-running EMG. Neurophysiologists continuously monitored EMG responses and blindly analyzed intraoperative findings and final EMG interpretations for abnormalities. Seven patients collectively underwent 8 lymphatic malformation surgeries. Median age was 30 months (2-105 months). Lymphatic malformation diagnosis was recorded in 6/8 surgeries. Facial nerve function was House-Brackmann grade I in 8/8 cases preoperatively. Facial nerve was abnormally elongated in 1/8 cases. EMG monitoring recorded abnormal activity in 4/8 cases--two suggesting facial nerve irritation, and two with possible facial nerve damage. Transient or long-term facial nerve paresis occurred in 1/8 cases (House-Brackmann grade II). Preoperative facial nerve mapping combined with continuous intraoperative EMG and mapping is a successful method of identifying the facial nerve course and protecting it from injury during resection of cervicofacial lymphatic malformations involving the facial nerve.

  14. The vestibulocochlear nerve (VIII).

    Science.gov (United States)

    Benoudiba, F; Toulgoat, F; Sarrazin, J-L

    2013-10-01

    The vestibulocochlear nerve (8th cranial nerve) is a sensory nerve. It is made up of two nerves, the cochlear, which transmits sound and the vestibular which controls balance. It is an intracranial nerve which runs from the sensory receptors in the internal ear to the brain stem nuclei and finally to the auditory areas: the post-central gyrus and superior temporal auditory cortex. The most common lesions responsible for damage to VIII are vestibular Schwannomas. This report reviews the anatomy and various investigations of the nerve. Copyright © 2013. Published by Elsevier Masson SAS.

  15. Cochlear neuropathy in human presbycusis: Confocal analysis of hidden hearing loss in post-mortem tissue.

    Science.gov (United States)

    Viana, Lucas M; O'Malley, Jennifer T; Burgess, Barbara J; Jones, Dianne D; Oliveira, Carlos A C P; Santos, Felipe; Merchant, Saumil N; Liberman, Leslie D; Liberman, M Charles

    2015-09-01

    Recent animal work has suggested that cochlear synapses are more vulnerable than hair cells in both noise-induced and age-related hearing loss. This synaptopathy is invisible in conventional histopathological analysis, because cochlear nerve cell bodies in the spiral ganglion survive for years, and synaptic analysis requires special immunostaining or serial-section electron microscopy. Here, we show that the same quadruple-immunostaining protocols that allow synaptic counts, hair cell counts, neuronal counts and differentiation of afferent and efferent fibers in mouse can be applied to human temporal bones, when harvested within 9 h post-mortem and prepared as dissected whole mounts of the sensory epithelium and osseous spiral lamina. Quantitative analysis of five "normal" ears, aged 54-89 yrs, without any history of otologic disease, suggests that cochlear synaptopathy and the degeneration of cochlear nerve peripheral axons, despite a near-normal hair cell population, may be an important component of human presbycusis. Although primary cochlear nerve degeneration is not expected to affect audiometric thresholds, it may be key to problems with hearing in noise that are characteristic of declining hearing abilities in the aging ear. Copyright © 2015 Elsevier B.V. All rights reserved.

  16. Cochlear implant revision surgeries in children.

    Science.gov (United States)

    Amaral, Maria Stella Arantes do; Reis, Ana Cláudia Mirândola B; Massuda, Eduardo T; Hyppolito, Miguel Angelo

    2018-02-16

    The surgery during which the cochlear implant internal device is implanted is not entirely free of risks and may produce problems that will require revision surgeries. To verify the indications for cochlear implantation revision surgery for the cochlear implant internal device, its effectiveness and its correlation with certain variables related to language and hearing. A retrospective study of patients under 18 years submitted to cochlear implant Surgery from 2004 to 2015 in a public hospital in Brazil. Data collected were: age at the time of implantation, gender, etiology of the hearing loss, audiological and oral language characteristics of each patient before and after Cochlear Implant surgery and any need for surgical revision and the reason for it. Two hundred and sixty-five surgeries were performed in 236 patients. Eight patients received a bilateral cochlear implant and 10 patients required revision surgery. Thirty-two surgeries were necessary for these 10 children (1 bilateral cochlear implant), of which 21 were revision surgeries. In 2 children, cochlear implant removal was necessary, without reimplantation, one with cochlear malformation due to incomplete partition type I and another due to trauma. With respect to the cause for revision surgery, of the 8 children who were successfully reimplanted, four had cochlear calcification following meningitis, one followed trauma, one exhibited a facial nerve malformation, one experienced a failure of the cochlear implant internal device and one revision surgery was necessary because the electrode was twisted. The incidence of the cochlear implant revision surgery was 4.23%. The period following the revision surgeries revealed an improvement in the subject's hearing and language performance, indicating that these surgeries are valid in most cases. Copyright © 2018 Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial. Published by Elsevier Editora Ltda. All rights reserved.

  17. Systematic review of compound action potentials as predictors for cochlear implant performance

    NARCIS (Netherlands)

    van Eijl, Ruben H M; Buitenhuis, Patrick J.; Stegeman, Inge; Klis, Sjaak F L; Grolman, Wilko

    2017-01-01

    Objectives/Hypothesis: The variability in speech perception between cochlear implant users is thought to result from the degeneration of the auditory nerve. Degeneration of the auditory nerve, histologically assessed, correlates with electrophysiologically acquired measures, such as electrically

  18. Immediate and delayed cochlear neuropathy after noise exposure in pubescent mice.

    Directory of Open Access Journals (Sweden)

    Jane Bjerg Jensen

    Full Text Available Moderate acoustic overexposure in adult rodents is known to cause acute loss of synapses on sensory inner hair cells (IHCs and delayed degeneration of the auditory nerve, despite the completely reversible temporary threshold shift (TTS and morphologically intact hair cells. Our objective was to determine whether a cochlear synaptopathy followed by neuropathy occurs after noise exposure in pubescence, and to define neuropathic versus non-neuropathic noise levels for pubescent mice. While exposing 6 week old CBA/CaJ mice to 8-16 kHz bandpass noise for 2 hrs, we defined 97 dB sound pressure level (SPL as the threshold for this particular type of neuropathic exposure associated with TTS, and 94 dB SPL as the highest non-neuropathic noise level associated with TTS. Exposure to 100 dB SPL caused permanent threshold shift although exposure of 16 week old mice to the same noise is reported to cause only TTS. Amplitude of wave I of the auditory brainstem response, which reflects the summed activity of the cochlear nerve, was complemented by synaptic ribbon counts in IHCs using confocal microscopy, and by stereological counts of peripheral axons and cell bodies of the cochlear nerve from 24 hours to 16 months post exposure. Mice exposed to neuropathic noise demonstrated immediate cochlear synaptopathy by 24 hours post exposure, and delayed neurodegeneration characterized by axonal retraction at 8 months, and spiral ganglion cell loss at 8-16 months post exposure. Although the damage was initially limited to the cochlear base, it progressed to also involve the cochlear apex by 8 months post exposure. Our data demonstrate a fine line between neuropathic and non-neuropathic noise levels associated with TTS in the pubescent cochlea.

  19. The Underlying Mechanism of Preventing Facial Nerve Stimulation by Triphasic Pulse Stimulation in Cochlear Implant Users Assessed With Objective Measure.

    Science.gov (United States)

    Bahmer, Andreas; Baumann, Uwe

    2016-10-01

    Triphasic pulse stimulation prevents from facial nerve stimulation (FNS) because of a different electromyographic input-output function compared with biphasic pulse stimulation. FNS is sometimes observed in cochlear implant users as an unwanted side effect of electrical stimulation of the auditory nerve. The common stimulation applied in current cochlear implant consists of biphasic pulse patterns. Two common clinical remedies to prevent unpleasant FNS caused by activation of certain electrodes are to expand their pulse phase duration or simply deactivate them. Unfortunately, in some patients these methods do not provide sufficient FNS prevention. In these patients triphasic pulse can prevent from FNS. The underlying mechanism is yet unclear. Electromyographic (EMG) recordings of muscles innervated by the facial nerve (musculi orbicularis ori and oculi) were applied to quantitatively assess the effects on FNS. Triphasic and biphasic fitting maps were compared in four subjects with severe FNS. Based on the recordings, a model is presented which intends to explain the beneficial effects of triphasic pulse application. Triphasic stimulation provided by fitting of an OPUS 2 speech processor device. For three patients, EMG was successfully recorded depending on stimulation level up to uncomfortable and intolerable FNS stimulation as upper boarder. The obtained EMG recordings demonstrated high individual variability. However, a difference between the input-output function for biphasic and triphasic pulse stimulation was visually observable. Compared with standard biphasic stimulation, triphasic pulses require higher stimulation levels to elicit an equal amount of FNS, as reflected by EMG amplitudes. In addition, we assume a steeper slope of the input-output function for biphasic pulse stimulation compared with triphasic pulse stimulation. Triphasic pulse stimulation prevents from FNS because of a smaller gradient of EMG input-output function compared with biphasic pulse

  20. Advances in cochlear implant telemetry: evoked neural responses, electrical field imaging, and technical integrity.

    NARCIS (Netherlands)

    Mens, L.H.M.

    2007-01-01

    During the last decade, cochlear implantation has evolved into a well-established treatment of deafness, predominantly because of many improvements in speech processing and the controlled excitation of the auditory nerve. Cochlear implants now also feature telemetry, which is highly useful to

  1. Aspects of temporal bone anatomy and pathology in conjunction with cochlear implant surgery

    Energy Technology Data Exchange (ETDEWEB)

    Stjernholm, Christina [Karolinska Inst., Stockholm (Sweden). Soedersjukhuset

    2003-07-01

    Cochlear implantation is a treatment for patients with severe sensorineural hearing loss/deafness, who get no help from ordinary hearing aids. The cochlear implant is surgically placed under the skin near the ear and a very thin electrode array is introduced into the cochlea of the inner ear, where it stimulates the remaining nerve fibers. The operation is complicated; it is performed with the aid of a microscope, and involves drilling very close to vital vessels and important nerves. High resolution computed tomography (CT) of the temporal bone is a part of the preoperative evaluation preceding cochlear implantation. It is a method for visualizing the bony structures of the middle and inner ear - to diagnose pathology and to describe the anatomy. The first work concerns CT of the temporal bone and cochlear implant surgery in children with CHARGE association. This is a rare condition with multiple congenital abnormalities, sometimes lethal. Children with CHARGE have different combinations of disabilities, of which impairments of vision and hearing, as well as balance problems and facial palsy can lead to developmental delay. There have been few reports of radiological temporal bone changes and none of cochlear implant surgery for this group. The work includes a report of the findings on preoperative CT and at surgery, as well as postimplant results in two children. A review of the latest diagnostic criteria of CHARGE and the temporal bone changes found in international literature is also included. The conclusion was that certain combinations of temporal bone changes in CHARGE are, if not specific, at least extremely rare in other materials. CT can visualize these changes and be used as a diagnostic tool. This is important, since some of the associated disabilities are not so obvious from the start. Early treatment is vital for the child's development. This work also shows that cochlear implantation may help some of these often very isolated children to

  2. Aspects of temporal bone anatomy and pathology in conjunction with cochlear implant surgery

    International Nuclear Information System (INIS)

    Stjernholm, Christina

    2003-01-01

    Cochlear implantation is a treatment for patients with severe sensorineural hearing loss/deafness, who get no help from ordinary hearing aids. The cochlear implant is surgically placed under the skin near the ear and a very thin electrode array is introduced into the cochlea of the inner ear, where it stimulates the remaining nerve fibers. The operation is complicated; it is performed with the aid of a microscope, and involves drilling very close to vital vessels and important nerves. High resolution computed tomography (CT) of the temporal bone is a part of the preoperative evaluation preceding cochlear implantation. It is a method for visualizing the bony structures of the middle and inner ear - to diagnose pathology and to describe the anatomy. The first work concerns CT of the temporal bone and cochlear implant surgery in children with CHARGE association. This is a rare condition with multiple congenital abnormalities, sometimes lethal. Children with CHARGE have different combinations of disabilities, of which impairments of vision and hearing, as well as balance problems and facial palsy can lead to developmental delay. There have been few reports of radiological temporal bone changes and none of cochlear implant surgery for this group. The work includes a report of the findings on preoperative CT and at surgery, as well as postimplant results in two children. A review of the latest diagnostic criteria of CHARGE and the temporal bone changes found in international literature is also included. The conclusion was that certain combinations of temporal bone changes in CHARGE are, if not specific, at least extremely rare in other materials. CT can visualize these changes and be used as a diagnostic tool. This is important, since some of the associated disabilities are not so obvious from the start. Early treatment is vital for the child's development. This work also shows that cochlear implantation may help some of these often very isolated children to communicate

  3. Reactive neurogenesis and down-regulation of the potassium-chloride cotransporter KCC2 in the cochlear nuclei after cochlear deafferentation

    Directory of Open Access Journals (Sweden)

    Brahim Tighilet

    2016-08-01

    Full Text Available While many studies have been devoted to investigating the homeostatic plasticity triggered by cochlear hearing loss, the cellular and molecular mechanisms involved in these central changes remain elusive. In the present study, we investigated the possibility of reactive neurogenesis after unilateral cochlear nerve section in the cochlear nucleus of cats. We found a strong cell proliferation in all the cochlear nucleus sub-divisions ipsilateral to the lesion. Most of the newly generated cells survive up to one month after cochlear deafferentation in all cochlear nuclei (except the dorsal cochlear nucleus and give rise to a variety of cell types, i.e. microglial cells, astrocytes and neurons. Interestingly, many of the newborn neurons had an inhibitory (GABAergic phenotype. This result is intriguing since sensory deafferentation is usually accompanied by enhanced excitation, consistent with a reduction in central inhibition. The membrane potential effect of GABA depends, however, on the intra-cellular chloride concentration, which is maintained at low levels in adults by the potassium chloride co-transporter KCC2. The KCC2 density on the plasma membrane of neurons was then assessed after cochlear deafferentation in the cochlear nuclei ipsilateral and contralateral to the lesion. Cochlear deafferentation is accompanied by a strong down-regulation of KCC2 ipsilateral to the lesion at 3 and 30 days post-lesion. This study suggests that reactive neurogenesis and downregulation of KCC2 is part of the vast repertoire involved in homeostatic plasticity triggered by hearing loss. These central changes may also play a role in the generation of tinnitus and hyperacusis.

  4. Effect of Bluetooth headset and mobile phone electromagnetic fields on the human auditory nerve.

    Science.gov (United States)

    Mandalà, Marco; Colletti, Vittorio; Sacchetto, Luca; Manganotti, Paolo; Ramat, Stefano; Marcocci, Alessandro; Colletti, Liliana

    2014-01-01

    The possibility that long-term mobile phone use increases the incidence of astrocytoma, glioma and acoustic neuroma has been investigated in several studies. Recently, our group showed that direct exposure (in a surgical setting) to cell phone electromagnetic fields (EMFs) induces deterioration of auditory evoked cochlear nerve compound action potential (CNAP) in humans. To verify whether the use of Bluetooth devices reduces these effects, we conducted the present study with the same experimental protocol. Randomized trial. Twelve patients underwent retrosigmoid vestibular neurectomy to treat definite unilateral Ménière's disease while being monitored with acoustically evoked CNAPs to assess direct mobile phone exposure or alternatively the EMF effects of Bluetooth headsets. We found no short-term effects of Bluetooth EMFs on the auditory nervous structures, whereas direct mobile phone EMF exposure confirmed a significant decrease in CNAPs amplitude and an increase in latency in all subjects. The outcomes of the present study show that, contrary to the finding that the latency and amplitude of CNAPs are very sensitive to EMFs produced by the tested mobile phone, the EMFs produced by a common Bluetooth device do not induce any significant change in cochlear nerve activity. The conditions of exposure, therefore, differ from those of everyday life, in which various biological tissues may reduce the EMF affecting the cochlear nerve. Nevertheless, these novel findings may have important safety implications. © 2013 The American Laryngological, Rhinological and Otological Society, Inc.

  5. [Does intraoperative nerve monitoring reduce the rate of recurrent nerve palsies during thyroid surgery?].

    Science.gov (United States)

    Timmermann, W; Dralle, H; Hamelmann, W; Thomusch, O; Sekulla, C; Meyer, Th; Timm, S; Thiede, A

    2002-05-01

    Two different aspects of the influence of neuromonitoring on the possible reduction of post-operative recurrent laryngeal nerve palsies require critical examination: the nerve identification and the monitoring of it's functions. Due to the additional information from the EMG signals, neuromonitoring is the best method for identifying the nerves as compared to visual identification alone. There are still no randomized studies available that compare the visual and electrophysiological recurrent laryngeal nerve detection in thyroid operations with respect to the postoperative nerve palsies. Nevertheless, comparisons with historical collectives show that a constant low nerve-palsy-rate was achieved with electrophysiological detection in comparison to visual detection. The rate of nerve identification is normally very high and amounts to 99 % in our own patients. The data obtained during the "Quality assurance of benign and malignant Goiter" study show that in hemithyreoidectomy and subtotal resection, lower nerve-palsy-rates are achieved with neuromonitoring as compared to solely visual detection. Following subtotal resection, this discrepancy becomes even statistically significant. While monitoring the nerve functions with the presently used neuromonitoring technique, it is possible to observe the EMG-signal remaining constant or decreasing in volume. Assuming that a constant neuromonitoring signal represents a normal vocal cord, our evaluation shows that there is a small percentage of false negative and positive results. Looking at the permanent recurrent nerve palsy rates, this method has a specificity of 98 %, a sensitivity of 100 %, a positive prognostic value of 10 %, and a negative prognostic value of 100 %. Although an altered neuromonitoring signal can be taken as a clear indication of eventual nerve damage, an absolutely reliable statement about the postoperative vocal cord function is presently not possible with intraoperative neuromonitoring.

  6. Diffusion tensor imaging of the auditory nerve in patients with acquired single-sided deafness

    DEFF Research Database (Denmark)

    Vos, Sjoerd; Haakma, Wieke; Versnel, Huib

    2015-01-01

    following cochlear hair cell loss, and the amount of degeneration may considerably differ between the two ears, also in patients with bilateral deafness. A measure that reflects the nerve's condition would help to assess the best of both nerves and decide accordingly which ear should be implanted......A cochlear implant (CI) can restore hearing in patients with profound sensorineural hearing loss by direct electrical stimulation of the auditory nerve. Therefore, the viability of the auditory nerve is vitally important in successful hearing recovery. However, the nerve typically degenerates...... single-sided sensorineural hearing loss. A specialized acquisition protocol was designed for a 3 T MRI scanner to image the small nerve bundle. The nerve was reconstructed using fiber tractography and DTI metrics - which reflect the nerve's microstructural properties - were computed per tract. Comparing...

  7. Cochlear implant: what the radiologist should know; Implante coclear: o que o radiologista precisa saber

    Energy Technology Data Exchange (ETDEWEB)

    Gomes, Natalia Delage; Couto, Caroline Laurita Batista; Gaiotti, Juliana Oggioni; Costa, Ana Maria Doffemond; Ribeiro, Marcelo Almeida; Diniz, Renata Lopes Furletti Caldeira, E-mail: nataliadelagegomes@gmail.com [Hospital Mater Dei, Belo Horizonte, MG (Brazil). Unidade de Radiologia e Diagnostico por Imagem

    2013-05-15

    Cochlear implant is the method of choice in the treatment of deep sensorineural hypoacusis, particularly in patients where conventional amplification devices do not imply noticeable clinical improvement. Imaging findings are crucial in the indication or contraindication for such surgical procedure. In the assessment of the temporal bone, radiologists should be familiar with relative or absolute contraindication factors, as well as with factors that might significantly complicate the implantation. Some criteria such as cochlear nerve aplasia, labyrinthine and/or cochlear aplasia are still considered as absolute contraindications, in spite of studies bringing such criteria into question. Cochlear dysplasias constitute relative contraindications, among them labyrinthitis ossificans is highlighted. Other alterations may be mentioned as complicating agents in the temporal bone assessment, namely, hypoplasia of the mastoid process, aberrant facial nerve, otomastoiditis, otosclerosis, dehiscent jugular bulb, enlarged endolymphatic duct and sac. The experienced radiologist assumes an important role in the evaluation of this condition. (author)

  8. Intraoperative Recurrent Laryngeal Nerve Monitoring in a Patient with Contralateral Vocal Fold Palsy

    Directory of Open Access Journals (Sweden)

    Bub-Se Na

    2017-10-01

    Full Text Available Recurrent laryngeal nerve injury can develop following cervical or thoracic surgery; however, few reports have described intraoperative recurrent laryngeal nerve monitoring. Consensus regarding the use of this technique during thoracic surgery is lacking. We used intraoperative recurrent laryngeal nerve monitoring in a patient with contralateral vocal cord paralysis who was scheduled for completion pneumonectomy. This case serves as an example of intraoperative recurrent laryngeal nerve monitoring during thoracic surgery and supports this indication for its use.

  9. Neurophysiological intraoperative monitoring during an optic nerve schwannoma removal.

    Science.gov (United States)

    San-Juan, Daniel; Escanio Cortés, Manuel; Tena-Suck, Martha; Orozco Garduño, Adolfo Josué; López Pizano, Jesús Alejandro; Villanueva Domínguez, Jonathan; Fernández Gónzalez-Aragón, Maricarmen; Gómez-Amador, Juan Luis

    2017-10-01

    This paper reports the case of a patient with optic nerve schwannoma and the first use of neurophysiological intraoperative monitoring of visual evoked potentials during the removal of such tumor with no postoperative visual damage. Schwannomas are benign neoplasms of the peripheral nervous system arising from the neural crest-derived Schwann cells, these tumors are rarely located in the optic nerve and the treatment consists on surgical removal leading to high risk of damage to the visual pathway. Case report of a thirty-year-old woman with an optic nerve schwannoma. The patient underwent surgery for tumor removal on the left optic nerve through a left orbitozygomatic approach with intraoperative monitoring of left II and III cranial nerves. We used Nicolet Endeavour CR IOM (Carefusion, Middleton WI, USA) to performed visual evoked potentials stimulating binocularly with LED flash goggles with the patient´s eyes closed and direct epidural optic nerve stimulation delivering rostral to the tumor a rectangular current pulse. At follow up examinations 7 months later, the left eye visual acuity was 20/60; Ishihara score was 8/8 in both eyes; the right eye photomotor reflex was normal and left eye was mydriatic and arreflectic; optokinetic reflex and ocular conjugate movements were normal. In this case, the epidural direct electrical stimulation of optic nerve provided stable waveforms during optic nerve schwannoma resection without visual loss.

  10. Outcomes and Time to Emergence of Auditory Skills After Cochlear Implantation of Children With Charge Syndrome.

    Science.gov (United States)

    Young, Nancy M; Tournis, Elizabeth; Sandy, Jenelle; Hoff, Stephen R; Ryan, Maura

    2017-09-01

    Review perioperative complications, benefits, and the timeframe over which auditory skills develop in children with CHARGE syndrome who receive a cochlear implant (CI). IRB-approved retrospective chart review of children with CHARGE syndrome who had at least 12 months of cochlear implant use. Tertiary care children's hospital. Twelve children, seven males and five females. Mean age implant = 3.5 years (1.7-8.2 yr); mean duration follow-up = 4.7 years (1.5-10.1 yr). Cochlear implantation. Auditory skills categorized into four levels, temporal bone imaging findings, perioperative complications, time to emergence of speech perception, expressive communication mode. All children imaged with magnetic resonance imaging had cochlear nerve deficiency in at least one ear. Speech awareness threshold improved with the CI compared with aided preoperative in 83% of children, with means of 51.7 dB SAT preoperative and 27.1 dB with the CI (p ≤ 0.002). Overall, four children improved to auditory Level 2 (improved detection), three obtained Level 3 (closed-set speech perception), and three had open-set speech perception with their CIs (Level 4) that was first evident at 3.5, 3.3, and 0.8 years postimplant testing. Two children had minimal or limited improvement. One child with hypoplasia of the cochlear nerve obtained open-set levels. Auditory skills may develop slowly in children with CHARGE syndrome who receive a CI but most can achieve at least improved detection. In our series, half acquired some speech perception ability. Cochlear nerve deficiency is frequent, but should not be a contraindication to implantation.

  11. Serotonin projection patterns to the cochlear nucleus.

    Science.gov (United States)

    Thompson, A M; Thompson, G C

    2001-07-13

    The cochlear nucleus is well known as an obligatory relay center for primary auditory nerve fibers. Perhaps not so well known is the neural input to the cochlear nucleus from cells containing serotonin that reside near the midline in the midbrain raphe region. Although the specific locations of the main, if not sole, sources of serotonin within the dorsal cochlear nucleus subdivision are known to be the dorsal and median raphe nuclei, sources of serotonin located within other cochlear nucleus subdivisions are not currently known. Anterograde tract tracing was used to label fibers originating from the dorsal and median raphe nuclei while fluorescence immunohistochemistry was used to simultaneously label specific serotonin fibers in cat. Biotinylated dextran amine was injected into the dorsal and median raphe nuclei and was visualized with Texas Red, while serotonin was visualized with fluorescein. Thus, double-labeled fibers were unequivocally identified as serotoninergic and originating from one of the labeled neurons within the dorsal and median raphe nuclei. Double-labeled fiber segments, typically of fine caliber with oval varicosities, were observed in many areas of the cochlear nucleus. They were found in the molecular layer of the dorsal cochlear nucleus, in the small cell cap region, and in the granule cell and external regions of the cochlear nuclei, bilaterally, of all cats. However, the density of these double-labeled fiber segments varied considerably depending upon the exact region in which they were found. Fiber segments were most dense in the dorsal cochlear nucleus (especially in the molecular layer) and the large spherical cell area of the anteroventral cochlear nucleus; they were moderately dense in the small cell cap region; and fiber segments were least dense in the octopus and multipolar cell regions of the posteroventral cochlear nucleus. Because of the presence of labeled fiber segments in subdivisions of the cochlear nucleus other than the

  12. Conductive Hearing Loss Has Long-Lasting Structural and Molecular Effects on Presynaptic and Postsynaptic Structures of Auditory Nerve Synapses in the Cochlear Nucleus.

    Science.gov (United States)

    Clarkson, Cheryl; Antunes, Flora M; Rubio, Maria E

    2016-09-28

    Sound deprivation by conductive hearing loss increases hearing thresholds, but little is known about the response of the auditory brainstem during and after conductive hearing loss. Here, we show in young adult rats that 10 d of monaural conductive hearing loss (i.e., earplugging) leads to hearing deficits that persist after sound levels are restored. Hearing thresholds in response to clicks and frequencies higher than 8 kHz remain increased after a 10 d recovery period. Neural output from the cochlear nucleus measured at 10 dB above threshold is reduced and followed by an overcompensation at the level of the lateral lemniscus. We assessed whether structural and molecular substrates at auditory nerve (endbulb of Held) synapses in the cochlear nucleus could explain these long-lasting changes in hearing processing. During earplugging, vGluT1 expression in the presynaptic terminal decreased and synaptic vesicles were smaller. Together, there was an increase in postsynaptic density (PSD) thickness and an upregulation of GluA3 AMPA receptor subunits on bushy cells. After earplug removal and a 10 d recovery period, the density of synaptic vesicles increased, vesicles were also larger, and the PSD of endbulb synapses was larger and thicker. The upregulation of the GluA3 AMPAR subunit observed during earplugging was maintained after the recovery period. This suggests that GluA3 plays a role in plasticity in the cochlear nucleus. Our study demonstrates that sound deprivation has long-lasting alterations on structural and molecular presynaptic and postsynaptic components at the level of the first auditory nerve synapse in the auditory brainstem. Despite being the second most prevalent form of hearing loss, conductive hearing loss and its effects on central synapses have received relatively little attention. Here, we show that 10 d of monaural conductive hearing loss leads to an increase in hearing thresholds, to an increased central gain upstream of the cochlear nucleus at

  13. Pre-, intra- and post-operative imaging of cochlear implants

    Energy Technology Data Exchange (ETDEWEB)

    Vogl, T.J.; Naguib, N.N.N.; Burck, I. [University Hospital Frankfurt (Germany). Inst. of Diagnostic and Interventional Radiology; Tawfik, A. [Mansoura Univ. (Egypt). Dept. of Diagnostic and Interventional Radiology; Emam, A. [University Hospital Alexandria (Egypt). Dept. of Diagnostic and Interventional Radiology; Nour-Eldin, A. [University Hospital Cairo (Egypt). Dept. of Radiology; Stoever, T. [University Hospital of Frankfurt (Germany). Dept. of Otolaryngology

    2015-11-15

    The purpose of this review is to present essential imaging aspects in patients who are candidates for a possible cochlear implant as well as in postsurgical follow-up. Imaging plays a major role in providing information on preinterventional topography, variations and possible infections. Preoperative imaging using DVT, CT, MRI or CT and MRI together is essential for candidate selection, planning of surgical approach and exclusion of contraindications like the complete absence of the cochlea or cochlear nerve, or infection. Relative contraindications are variations of the cochlea and vestibulum. Intraoperative imaging can be performed by fluoroscopy, mobile radiography or DVT. Postoperative imaging is regularly performed by conventional X-ray, DVT, or CT. In summary, radiological imaging has its essential role in the pre- and post-interventional period for patients who are candidates for cochlear implants.

  14. Cochlear Implant

    Directory of Open Access Journals (Sweden)

    Mehrnaz Karimi

    1992-04-01

    Full Text Available People with profound hearing loss are not able to use some kinds of conventional amplifiers due to the nature of their loss . In these people, hearing sense is stimulated only when the auditory nerve is activated via electrical stimulation. This stimulation is possible through cochlear implant. In fact, for the deaf people who have good mental health and can not use surgical and medical treatment and also can not benefit from air and bone conduction hearing aids, this device is used if they have normal central auditory system. The basic parts of the device included: Microphone, speech processor, transmitter, stimulator and receiver, and electrode array.

  15. Perceptual consequences of disrupted auditory nerve activity.

    Science.gov (United States)

    Zeng, Fan-Gang; Kong, Ying-Yee; Michalewski, Henry J; Starr, Arnold

    2005-06-01

    Perceptual consequences of disrupted auditory nerve activity were systematically studied in 21 subjects who had been clinically diagnosed with auditory neuropathy (AN), a recently defined disorder characterized by normal outer hair cell function but disrupted auditory nerve function. Neurological and electrophysical evidence suggests that disrupted auditory nerve activity is due to desynchronized or reduced neural activity or both. Psychophysical measures showed that the disrupted neural activity has minimal effects on intensity-related perception, such as loudness discrimination, pitch discrimination at high frequencies, and sound localization using interaural level differences. In contrast, the disrupted neural activity significantly impairs timing related perception, such as pitch discrimination at low frequencies, temporal integration, gap detection, temporal modulation detection, backward and forward masking, signal detection in noise, binaural beats, and sound localization using interaural time differences. These perceptual consequences are the opposite of what is typically observed in cochlear-impaired subjects who have impaired intensity perception but relatively normal temporal processing after taking their impaired intensity perception into account. These differences in perceptual consequences between auditory neuropathy and cochlear damage suggest the use of different neural codes in auditory perception: a suboptimal spike count code for intensity processing, a synchronized spike code for temporal processing, and a duplex code for frequency processing. We also proposed two underlying physiological models based on desynchronized and reduced discharge in the auditory nerve to successfully account for the observed neurological and behavioral data. These methods and measures cannot differentiate between these two AN models, but future studies using electric stimulation of the auditory nerve via a cochlear implant might. These results not only show the unique

  16. The acquisition of personal pronouns in cochlear-implanted children

    NARCIS (Netherlands)

    Verbist, Annemie Josee Jozef

    2010-01-01

    Today, many deaf children can be given access to oral language thanks to a cochlear implant, a surgically implanted electronic device that provides a sense of sound thanks to electric stimulation of the auditory nerve. In this study, the acquisition of personal pronouns is considered to be a measure

  17. Diffusion tensor imaging of the auditory nerve in patients with long-term single-sided deafness

    NARCIS (Netherlands)

    Vos, Sjoerd; Haakma, Wieke; Versnel, Huib; Froeling, Martijn; Speleman, Lucienne; Dik, Pieter; Viergever, Max A.; Leemans, Alexander; Grolman, Wilko

    A cochlear implant (CI) can restore hearing in patients with profound sensorineural hearing loss by direct electrical stimulation of the auditory nerve. Therefore, the viability of the auditory nerve is vitally important in successful hearing recovery. However, the nerve typically degenerates

  18. Cochlear NMDA Receptors as a Therapeutic Target of Noise-Induced Tinnitus

    Directory of Open Access Journals (Sweden)

    Dan Bing

    2015-03-01

    Full Text Available Background: Accumulating evidence suggests that tinnitus may occur despite normal auditory sensitivity, probably linked to partial degeneration of the cochlear nerve and damage of the inner hair cell (IHC synapse. Damage to the IHC synapses and deafferentation may occur even after moderate noise exposure. For both salicylate- and noise-induced tinnitus, aberrant N-methyl-d-aspartate (NMDA receptor activation and related auditory nerve excitation have been suggested as origin of cochlear tinnitus. Accordingly, NMDA receptor inhibition has been proposed as a pharmacologic approach for treatment of synaptopathic tinnitus. Methods: Round-window application of the NMDA receptor antagonist AM-101 (Esketamine hydrochloride gel; Auris Medical AG, Basel, Switzerland was tested in an animal model of tinnitus induced by acute traumatic noise. The study included the quantification of IHC ribbon synapses as a correlate for deafferentation as well as the measurement of the auditory brainstem response (ABR to close-threshold sensation level stimuli as an indication of sound-induced auditory nerve activity. Results: We have shown that AM-101 reduced the trauma-induced loss of IHC ribbons and counteracted the decline of ABR wave I amplitude generated in the cochlea/auditory nerve. Conclusion: Local round-window application of AM-101 may be a promising therapeutic intervention for the treatment of synaptopathic tinnitus.

  19. Parotid tumours: clinical and oncologic outcomes after microscope-assisted parotidectomy with intraoperative nerve monitoring

    OpenAIRE

    Carta, F.; N., Chuchueva; C., Gerosa; S., Sionis; R.A., Caria; R., Puxeddu

    2017-01-01

    SUMMARY Temporary and permanent facial nerve dysfunctions can be observed after parotidectomy for benign and malignant lesions. Intraoperative nerve monitoring is a recognised tool for the preservation of the nerve, while the efficacy of the operative microscope has been rarely stated. The authors report their experience on 198 consecutive parotidectomies performed on 196 patients with the aid of the operative microscope and intraoperative nerve monitoring. 145 parotidectomies were performed ...

  20. Monitoring of recurrent and superior laryngeal nerve function using an Airwayscope™ during thyroid surgery.

    Science.gov (United States)

    Ijichi, Kei; Sasano, Hiroshi; Harima, Megumi; Murakami, Shingo

    2017-10-01

    In thyroid surgery, intraoperative identification and preservation of the recurrent laryngeal nerve (RLN) and superior laryngeal nerve external branch (SLNEB) are crucial. Several reports have proposed that electromyography (EMG) monitoring is an acceptable adjunct for identification and preservation of the RLN. However, a limited number of hospitals have access to an EMG monitoring system. Therefore, the development of another viable monitoring method is required. The aim of the present study was to design a new RLN and SLNEB monitoring method combining an Airwayscope™ (AWS) and a facial nerve stimulator. The facial nerve-stimulating electrode stimulates the RLN or SLNEB, so that the movement of the vocal cord may be observed with an AWS. This monitoring method was performed on 10 patients with a thyroid tumor. In all the cases, RLN and SLNEB were identified and vocal cord function was preserved. All the patients exhibited normal vocal cord function following surgery. Thus, the new RLN and SLNEB monitoring method using an AWS and a facial nerve stimulator is useful in thyroid surgery, and this method may be used as a reliable and available alternative to EMG monitoring to ensure the normal function of the vocal cord.

  1. Intraoperative monitoring of lower cranial nerves in skull base surgery: technical report and review of 123 monitored cases.

    Science.gov (United States)

    Topsakal, Cahide; Al-Mefty, Ossama; Bulsara, Ketan R; Williford, Veronica S

    2008-01-01

    The fundamental goal of skull base surgery is tumor removal with preservation of neurological function. Injury to the lower cranial nerves (LCN; CN 9-12) profoundly affects a patient's quality of life. Although intraoperative cranial nerve monitoring (IOM) is widely practiced for other cranial nerves, literature addressing the LCN is scant. We examined the utility of IOM of the LCN in a large patient series. One hundred twelve patients underwent 123 skull base operations with IOM between January 1994 to December 1999. The vagus nerve (n=37), spinal accessory nerve (n=118), and the hypoglossal nerve (n=83) were monitored intraoperatively. Electromyography (EMG) and compound muscle action potentials (CMAP) were recorded from the relevant muscles after electrical stimulation. This data was evaluated retrospectively. Patients who underwent IOM tended to have larger tumors with more intricate involvement of the lower cranial nerves. Worsening of preoperative lower cranial nerve function was seen in the monitored and unmonitored groups. With the use of IOM in the high risk group, LCN injury was reduced to a rate equivalent to that of the lower risk group (p>0.05). The immediate feedback obtained with IOM may prevent injury to the LCN due to surgical manipulation. It can also help identify the course of a nerve in patients with severely distorted anatomy. These factors may facilitate gross total tumor resection with cranial nerve preservation. The incidence of high false positive and negative CMAP and the variability in CMAP amplitude and threshold can vary depending on individual and technical factors.

  2. MRI enhancement of the facial nerve with Gd-DTPA, 2; Investigation of enhanced nerve portions in patients with facial palsy

    Energy Technology Data Exchange (ETDEWEB)

    Yanagida, Masahiro [Kansai Medical School, Moriguchi, Osaka (Japan)

    1993-08-01

    We performed enhanced MRI using Gd-DTPA in 84 patients with facial palsy. After assessing enhancement of the normal facial nerve, we examined enhancement in patients with Bell's palsy and Ramsay Hunt syndrome. In 95% of patients with Bell's palsy, enhancement was obtained in the distal IAC and labyrinthine portions. In 72%, enhancement was significant from the distal IAC portion through the vertical portion. In some of the patients who underwent enhanced MRI twice, increased signal intensity was observed in distal portions such as the vertical portion. In many cases of Ramsay Hunt syndrome, enhancement was seen extensively in the IAC portion through the vertical portion. In the subjects with internal auditory symptoms such as vertigo and tinnitus, enhancement of the IAC portion was seen not only in the facial nerve but also in the vestibular and the cochlear nerves. These results suggest that the vascular permeability of lesions in Bell's palsy may be increased from the distal IAC portion to the vertical portion. Judging from the present findings with Ramsay Hunt syndrome, symptoms related to the enhanced portions suggest that accompanying internal auditory symptoms occur due to inflammation of the IAC portions of cochlear and vestibular nerves. (author).

  3. [Cochlear implant in patients with congenital malformation of the inner ear].

    Science.gov (United States)

    Wan, Liang-cai; Guo, Meng-he; Qian, Yu-hong; Liu, Shuang-xiu; Zhang, Hong-zheng; Chen, Shuai-jun; Chen, Hao; Gong, Jian

    2009-10-01

    To summarize the clinical experience with multi-channel cochlear implantation in patients with inner ear malformations and evaluate and the outcomes of speech rehabilitation. A retrospective study was conducted in 295 patients receiving cochlear implantation from 1998 to 2007, including 25 patients with large vestibular aqueduct syndrome (LVAS), 9 with Modini malformation, and 5 with common cavity deformity. All the patients received the Nucleus24 cochlear implants. In LVAS cases, 4 had Nucleus 24R (ST) implants, 8 had Contuor implants, 10 had Contuor Advance, and the remaining cases used Nucleus24(M) straight-electrode implants. Severe gusher appeared in 3 cases of LVAS, and perilymph fluctuation were seen in other 15 cases. Four patients with Mondini malformation and 2 with common cavity malformation also experienced severe gusher, but the electrodes were inserted smoothly in all the patients without postoperative facial paralysis or cerebrospinal fluid leakage. The hearing threshold in these patients was similar to that in patients with normal cochlear structure. After speech rehabilitation for over 6 months, the abilities of speech discrimination and spoken language improved in all the cases in comparison with the preoperative lingual functions. Multi-channel cochlear implantation can be performed in patients with inner ear malformation, but should not be attempted in patients with poor cochlear and cochlear nerve development. A comprehensive pre-operative radiographic and audiological evaluation is essential.

  4. [Vestibulo-cochlear disturbances in the course of vaso-neural conflict of vestibule-cochlear nerve--diagnostic and therapeutic problems].

    Science.gov (United States)

    Orendorz-Fraczkowska, Krystyna; Jaworska, Marzena; Gawron, Wojciech; Badowski, Roman; Nadolska, Beata

    2007-01-01

    Symptoms encompassing sensorineural hearing loss, tinnitus and vertigo occur in many diseases of various origin. The diagnostics in such cases is especially difficult and often requires interdisciplinary cooperation. Despite of that many cases remain unexplained. The two cases with above mentioned symptoms (52 year-old woman and 46 year-old man) with differentiated clinical course were presented. The woman for one year experienced left sided, extreme tinnitus with paroxysmal vertigo and dizziness. The man with sudden monolateral hearing loss and tinnitus that disappeared after corticosteroid therapy, complained about recurrence of fluctuating hearing loss and tinnitus accompanied by chronic instability. The diagnostics of hearing and balance organs was performed (pure tone audiometry, impedance audiometry, DPOAE, ABR, ENG) complemented with computed tomography and Nuclear Resonance. Female patient presented bilateral mild sensorineural hearing loss, more intensive on the left side, male patient right sided sensorineural hearing loss in the frequencies from 250 to 1500 Hz. The elongation of some peak values in ABR test (with bilaterally proper otoacoustic emissions) as well as partial canal paresis on the hearing loss side suggested primary diagnosis of neoplasmatic process. It was an indication to perform radiological diagnostics. The radiologic findings revealed the contact of vestibulo-cochlear nerve with the loop of cerebellar inferior anterior artery within the internal acoustic canal. The course of the disease and diagnostic tests do not provide characteristic data that let diagnose neuro-vascular conflict. One has to be aware of such possibility in patients with intensive vertigo and dizziness that do not improve after treatment when other causes do not justify the symptoms.

  5. Parotid tumours: clinical and oncologic outcomes after microscope-assisted parotidectomy with intraoperative nerve monitoring.

    Science.gov (United States)

    Carta, F; Chuchueva, N; Gerosa, C; Sionis, S; Caria, R A; Puxeddu, R

    2017-10-01

    Temporary and permanent facial nerve dysfunctions can be observed after parotidectomy for benign and malignant lesions. Intraoperative nerve monitoring is a recognised tool for the preservation of the nerve, while the efficacy of the operative microscope has been rarely stated. The authors report their experience on 198 consecutive parotidectomies performed on 196 patients with the aid of the operative microscope and intraoperative nerve monitoring. 145 parotidectomies were performed for benign lesions and 53 for malignancies. Thirteen patients treated for benign tumours experienced temporary (11 cases) or permanent facial palsy (2 cases, both of House-Brackmann grade II). Ten patients with malignant tumour presented with preoperative facial nerve weakness that did not improve after treatment. Five and 6 patients with malignant lesion without preoperative facial nerve deficit experienced postoperative temporary and permanent weakness respectively (the sacrifice of a branch of the nerve was decided intraoperatively in 2 cases). Long-term facial nerve weakness after parotidectomy for lesions not directly involving or originating from the facial nerve (n = 185) was 2.7%. Patients treated for benign tumours of the extra facial portion of the gland without inflammatory behaviour (n = 91) had 4.4% facial nerve temporary weakness rate and no permanent palsy. The combined use of the operative microscope and intraoperative nerve monitoring seems to guarantee facial nerve preservation during parotidectomy. © Copyright by Società Italiana di Otorinolaringologia e Chirurgia Cervico-Facciale, Rome, Italy.

  6. Intraoperative Electrocochleographic Characteristics of Auditory Neuropathy Spectrum Disorder in Cochlear Implant Subjects

    Directory of Open Access Journals (Sweden)

    William J. Riggs

    2017-07-01

    Full Text Available Auditory neuropathy spectrum disorder (ANSD is characterized by an apparent discrepancy between measures of cochlear and neural function based on auditory brainstem response (ABR testing. Clinical indicators of ANSD are a present cochlear microphonic (CM with small or absent wave V. Many identified ANSD patients have speech impairment severe enough that cochlear implantation (CI is indicated. To better understand the cochleae identified with ANSD that lead to a CI, we performed intraoperative round window electrocochleography (ECochG to tone bursts in children (n = 167 and adults (n = 163. Magnitudes of the responses to tones of different frequencies were summed to measure the “total response” (ECochG-TR, a metric often dominated by hair cell activity, and auditory nerve activity was estimated visually from the compound action potential (CAP and auditory nerve neurophonic (ANN as a ranked “Nerve Score”. Subjects identified as ANSD (45 ears in children, 3 in adults had higher values of ECochG-TR than adult and pediatric subjects also receiving CIs not identified as ANSD. However, nerve scores of the ANSD group were similar to the other cohorts, although dominated by the ANN to low frequencies more than in the non-ANSD groups. To high frequencies, the common morphology of ANSD cases was a large CM and summating potential, and small or absent CAP. Common morphologies in other groups were either only a CM, or a combination of CM and CAP. These results indicate that responses to high frequencies, derived primarily from hair cells, are the main source of the CM used to evaluate ANSD in the clinical setting. However, the clinical tests do not capture the wide range of neural activity seen to low frequency sounds.

  7. Complications in cochlear implantation at the Clinical Center of Vojvodina

    Directory of Open Access Journals (Sweden)

    Dankuc Dragan

    2015-01-01

    Full Text Available Introduction. The first modern cochlear implantation in Serbia was performed on November 26, 2002 at the Center for Cochlear Implantation of the Clinic for Ear, Nose and Throat Diseases, Clinical Center of Vojvodina. Objective. The aim of the paper is the analysis of intraoperative and postoperative complications. Major complications include those resulting in the necessity for revision surgery, explantation, reimplantation, severe disease or even lethal outcomes. Minor complications resolve spontaneously or can be managed by conservative therapy and do not require any prolonged hospitalization of the patient. Methods. In the 2002-2013 period, 99 patients underwent surgical procedures and 100 cochlear implants were placed. Both intraoperative and postoperative complications were analyzed in the investigated patient population. Results. The analysis encompassed 99 patients, the youngest and the oldest ones being one year old and 61 years old, respectively. The complications were noticed in 11 patients, i.e. in 10.5% of 105 surgical procedures. The majority of procedures (89.5% were not accompanied by any post-surgical complications. Unsuccessful implantation in a single-step procedure (4.04% and transient facial nerve paralysis can be considered most frequent among our patients, whereas cochlear ossification (1.01% and transient ataxia (2.02% occurred rarely. Stimulation of the facial nerve (1.01%, intraoperative perilymph liquid gusher (1.01%, device failure and late infections (1.01% were recorded extremely rarely. Conclusion. Complications such as electrode extrusion, skin necrosis over the implant or meningitis, which is considered the most severe postoperative complication, have not been recorded at our Center since the very beginning. Absence of postoperative meningitis in patients treated at the Center can be attributed to timely pneumococcal vaccination of children.

  8. Intraoperative monitoring of marginal mandibular nerve during neck dissection.

    Science.gov (United States)

    Tirelli, Giancarlo; Bergamini, Pier Riccardo; Scardoni, Alessandro; Gatto, Annalisa; Boscolo Nata, Francesca; Marcuzzo, Alberto Vito

    2018-05-01

    The purpose of this study was to assess the efficacy of intraoperative nerve integrity monitoring (NIM) to prevent marginal mandibular nerve injuries during neck dissection. This prospective study compared 36 patients undergoing NIM-assisted neck dissection from July 2014 to March 2015 to a cohort of 35 patients subjected to neck dissection over an identical period of time before the technique was introduced. We also assessed possible correlations between marginal mandibular nerve injuries and other factors, such as anthropometric measurements, presence of clinical neck metastases, type of neck dissection, and site of primary tumor. The incidence of marginal mandibular nerve paralyses was significantly lower among the group of patients undergoing NIM-assisted neck dissection (P = .021). There was no significant difference in the duration of the procedure, and the technique resulted in a limited increase of cost. No other factor seemed to influence the onset of marginal mandibular nerve palsy. In our opinion, NIM is a valuable aid for preventing marginal mandibular nerve injuries during neck dissection. © 2018 Wiley Periodicals, Inc.

  9. MRI enhancement of the facial nerve with Gd-DTPA, 2; Investigation of enhanced nerve portions in patients with facial palsy

    Energy Technology Data Exchange (ETDEWEB)

    Yanagida, Masahiro (Kansai Medical School, Moriguchi, Osaka (Japan))

    1993-08-01

    We performed enhanced MRI using Gd-DTPA in 84 patients with facial palsy. After assessing enhancement of the normal facial nerve, we examined enhancement in patients with Bell's palsy and Ramsay Hunt syndrome. In 95% of patients with Bell's palsy, enhancement was obtained in the distal IAC and labyrinthine portions. In 72%, enhancement was significant from the distal IAC portion through the vertical portion. In some of the patients who underwent enhanced MRI twice, increased signal intensity was observed in distal portions such as the vertical portion. In many cases of Ramsay Hunt syndrome, enhancement was seen extensively in the IAC portion through the vertical portion. In the subjects with internal auditory symptoms such as vertigo and tinnitus, enhancement of the IAC portion was seen not only in the facial nerve but also in the vestibular and the cochlear nerves. These results suggest that the vascular permeability of lesions in Bell's palsy may be increased from the distal IAC portion to the vertical portion. Judging from the present findings with Ramsay Hunt syndrome, symptoms related to the enhanced portions suggest that accompanying internal auditory symptoms occur due to inflammation of the IAC portions of cochlear and vestibular nerves. (author).

  10. Cadaveric feasibility study of da Vinci Si-assisted cochlear implant with augmented visual navigation for otologic surgery.

    Science.gov (United States)

    Liu, Wen P; Azizian, Mahdi; Sorger, Jonathan; Taylor, Russell H; Reilly, Brian K; Cleary, Kevin; Preciado, Diego

    2014-03-01

    To our knowledge, this is the first reported cadaveric feasibility study of a master-slave-assisted cochlear implant procedure in the otolaryngology-head and neck surgery field using the da Vinci Si system (da Vinci Surgical System; Intuitive Surgical, Inc). We describe the surgical workflow adaptations using a minimally invasive system and image guidance integrating intraoperative cone beam computed tomography through augmented reality. To test the feasibility of da Vinci Si-assisted cochlear implant surgery with augmented reality, with visualization of critical structures and facilitation with precise cochleostomy for electrode insertion. Cadaveric case study of bilateral cochlear implant approaches conducted at Intuitive Surgical Inc, Sunnyvale, California. Bilateral cadaveric mastoidectomies, posterior tympanostomies, and cochleostomies were performed using the da Vinci Si system on a single adult human donor cadaveric specimen. Radiographic confirmation of successful cochleostomies, placement of a phantom cochlear implant wire, and visual confirmation of critical anatomic structures (facial nerve, cochlea, and round window) in augmented stereoendoscopy. With a surgical mean time of 160 minutes per side, complete bilateral cochlear implant procedures were successfully performed with no violation of critical structures, notably the facial nerve, chorda tympani, sigmoid sinus, dura, or ossicles. Augmented reality image overlay of the facial nerve, round window position, and basal turn of the cochlea was precise. Postoperative cone beam computed tomography scans confirmed successful placement of the phantom implant electrode array into the basal turn of the cochlea. To our knowledge, this is the first study in the otolaryngology-head and neck surgery literature examining the use of master-slave-assisted cochleostomy with augmented reality for cochlear implants using the da Vinci Si system. The described system for cochleostomy has the potential to improve the

  11. Speech Rate Normalization and Phonemic Boundary Perception in Cochlear-Implant Users

    Science.gov (United States)

    Jaekel, Brittany N.; Newman, Rochelle S.; Goupell, Matthew J.

    2017-01-01

    Purpose: Normal-hearing (NH) listeners rate normalize, temporarily remapping phonemic category boundaries to account for a talker's speech rate. It is unknown if adults who use auditory prostheses called cochlear implants (CI) can rate normalize, as CIs transmit degraded speech signals to the auditory nerve. Ineffective adjustment to rate…

  12. Our experience with facial nerve monitoring in vestibular schwannoma surgery under partial neuromuscular blockade.

    Science.gov (United States)

    Vega-Céliz, Jorge; Amilibia-Cabeza, Emili; Prades-Martí, José; Miró-Castillo, Nuria; Pérez-Grau, Marta; Pintanel Rius, Teresa; Roca-Ribas Serdà, Francesc

    2015-01-01

    Facial nerve monitoring is fundamental in the preservation of the facial nerve in vestibular schwannoma surgery. Our objective was to analyse the usefulness of facial nerve monitoring under partial neuromuscular blockade. This was a retrospective analysis of 69 patients operated in a tertiary hospital. We monitored 100% of the cases. In 75% of the cases, we could measure an electromyographic response after tumour resection. In 17 cases, there was an absence of electromyographic response. Fifteen of them had an anatomic lesion with loss of continuity of the facial nerve and, in 2 cases, there was a lesion with preservation of the nerve. Preoperative facial palsy (29% 7%; P=.0349), large tumour size (88 vs. 38%; P=.0276), and a non-functional audition (88 vs. 51%; P=.0276) were significantly related with an absence of electromyographic response. Facial nerve monitoring under neuromuscular blockade is possible and safe in patients without previous facial palsy. If the patient had an electromyographic response after tumour excision, they developed better facial function in the postoperative period and after a year of follow up. Copyright © 2014 Elsevier España, S.L.U. and Sociedad Española de Otorrinolaringología y Patología Cérvico-Facial. All rights reserved.

  13. Pre-operative Screening and Manual Drilling Strategies to Reduce the Risk of Thermal Injury During Minimally Invasive Cochlear Implantation Surgery.

    Science.gov (United States)

    Dillon, Neal P; Fichera, Loris; Kesler, Kyle; Zuniga, M Geraldine; Mitchell, Jason E; Webster, Robert J; Labadie, Robert F

    2017-09-01

    This article presents the development and experimental validation of a methodology to reduce the risk of thermal injury to the facial nerve during minimally invasive cochlear implantation surgery. The first step in this methodology is a pre-operative screening process, in which medical imaging is used to identify those patients that present a significant risk of developing high temperatures at the facial nerve during the drilling phase of the procedure. Such a risk is calculated based on the density of the bone along the drilling path and the thermal conductance between the drilling path and the nerve, and provides a criterion to exclude high-risk patients from receiving the minimally invasive procedure. The second component of the methodology is a drilling strategy for manually-guided drilling near the facial nerve. The strategy utilizes interval drilling and mechanical constraints to enable better control over the procedure and the resulting generation of heat. The approach is tested in fresh cadaver temporal bones using a thermal camera to monitor temperature near the facial nerve. Results indicate that pre-operative screening may successfully exclude high-risk patients and that the proposed drilling strategy enables safe drilling for low-to-moderate risk patients.

  14. [Applied anatomy of scala tympani inlet related to cochlear implantation].

    Science.gov (United States)

    Zou, Tuanming; Guo, Menghe; Zhang, Hongzheng; Shu, Fan; Xie, Nanping

    2012-06-01

    To investigate the related parameters of the temporal bone structure for determining the position of implanting electrode into the scala tympani in cochlear implantation surgery through the facial recess and epitympanum approach. In a surgical simulation experiment, 20 human temporal bones were studied and measured to determine the related parameters of the temporal bone structure. The distance 5.91∓0.29 mm between the short process of the incus and the round window niche, 2.11∓0.18 mm between the stapes and the round window niche, 6.70∓0.19 mm between the facial nerve in the perpendicular paragraph and the round window niche, 2.22∓0.21 mm from the pyramidal eminence to the round window, and 2.16∓0.14 mm between the stapes and the round window. The minimal distance between the implanting electrode and the vestibular window was 2.12∓0.19 mm. The distance between the cochleariform process and the round window niche was 3.79∓0.17 mm. The position of the cochlear electrode array insertion into the second cochlear turn was 2.25∓0.13 mm under the stapes. The location of the cochlear electrode array insertion into the second cochlear turn was 2.28∓0.20 mm inferior to the pyramidal eminence. These parameters provide a reference value to determine the different positions of cochlear electrode array insertion into the scale tympani in different patients.

  15. Cochlear Implantation in Patients with Neurofibromatosis Type 2 and Patients with Vestibular Schwannoma in the Only Hearing Ear

    Directory of Open Access Journals (Sweden)

    Erika Celis-Aguilar

    2012-01-01

    Full Text Available Cochlear implants are a new surgical option in the hearing rehabilitation of patients with neurofibromatosis type 2 (NF2 and patients with vestibular schwannoma (VS in the only hearing ear. Auditory brainstem implant (ABI has been the standard surgical treatment for these patients. We performed a literature review of patients with NF2 and patients with VS in the only hearing ear. Cochlear implantation (CI provided some auditory benefit in all patients. Preservation of cochlear nerve integrity is crucial after VS resection. Results ranged from environmental sound awareness to excellent benefit with telephone use. Promontory stimulation is recommended although not crucial. MRI can be performed safely in cochlear implanted patients.

  16. Spinal accessory nerve schwannomas masquerading as a fourth ventricular lesion

    Directory of Open Access Journals (Sweden)

    Shyam Sundar Krishnan

    2015-01-01

    Full Text Available Schwannomas are benign lesions that arise from the nerve sheath of cranial nerves. The most common schwannomas arise from the 8 th cranial nerve (the vestibulo-cochlear nerve followed by trigeminal and facial nerves and then from glossopharyngeal, vagus, and spinal accessory nerves. Schwannomas involving the oculomotor, trochlear, abducens and hypoglossal nerves are very rare. We report a very unusual spinal accessory nerve schwannoma which occupied the fourth ventricle and extended inferiorly to the upper cervical canal. The radiological features have been detailed. The diagnostic dilemma was due to its midline posterior location mimicking a fourth ventricular lesion like medulloblastoma and ependymoma. Total excision is the ideal treatment for these tumors. A brief review of literature with tabulations of the variants has been listed.

  17. Optic nerve sheath diameter: A novel way to monitor the brain

    Directory of Open Access Journals (Sweden)

    Seelora Sahu

    2017-01-01

    Full Text Available Measurement and monitoring of intracranial pressure is pivotal in management of brain injured patients. As a rapid and easily done bed side measurement, ultrasonography of the optic nerve sheath diameter presents itself as a possible replacement of the conventional invasive methods of intracranial pressure management. In this review we go through the evolution of optic nerve sheath diameter measurement as a novel marker of predicting raised intracranial pressure, the modalities by which it can be measured as well as its correlation with the invasive methods of intracranial pressure monitoring.

  18. MRI enhancement of the facial nerve with Gd-DTPA, 2

    International Nuclear Information System (INIS)

    Yanagida, Masahiro

    1993-01-01

    We performed enhanced MRI using Gd-DTPA in 84 patients with facial palsy. After assessing enhancement of the normal facial nerve, we examined enhancement in patients with Bell's palsy and Ramsay Hunt syndrome. In 95% of patients with Bell's palsy, enhancement was obtained in the distal IAC and labyrinthine portions. In 72%, enhancement was significant from the distal IAC portion through the vertical portion. In some of the patients who underwent enhanced MRI twice, increased signal intensity was observed in distal portions such as the vertical portion. In many cases of Ramsay Hunt syndrome, enhancement was seen extensively in the IAC portion through the vertical portion. In the subjects with internal auditory symptoms such as vertigo and tinnitus, enhancement of the IAC portion was seen not only in the facial nerve but also in the vestibular and the cochlear nerves. These results suggest that the vascular permeability of lesions in Bell's palsy may be increased from the distal IAC portion to the vertical portion. Judging from the present findings with Ramsay Hunt syndrome, symptoms related to the enhanced portions suggest that accompanying internal auditory symptoms occur due to inflammation of the IAC portions of cochlear and vestibular nerves. (author)

  19. A model of auditory nerve responses to electrical stimulation

    DEFF Research Database (Denmark)

    Joshi, Suyash Narendra; Dau, Torsten; Epp, Bastian

    Cochlear implants (CI) stimulate the auditory nerve (AN) with a train of symmetric biphasic current pulses comprising of a cathodic and an anodic phase. The cathodic phase is intended to depolarize the membrane of the neuron and to initiate an action potential (AP) and the anodic phase to neutral......Cochlear implants (CI) stimulate the auditory nerve (AN) with a train of symmetric biphasic current pulses comprising of a cathodic and an anodic phase. The cathodic phase is intended to depolarize the membrane of the neuron and to initiate an action potential (AP) and the anodic phase......-and-fire neuron with two partitions responding individually to anodic and cathodic stimulation. Membrane noise was parameterized based on reported relative spread of AN neurons. Firing efficiency curves and spike-latency distributions were simulated for monophasic and symmetric biphasic stimulation...

  20. Analog Integrated Circuit and System Design for a Compact, Low-Power Cochlear Implant

    NARCIS (Netherlands)

    Ngamkham, W.

    2015-01-01

    Cochlear Implants (CIs) are prosthetic devices that restore hearing in profoundly deaf patients by bypassing the damaged parts of the inner ear and directly stimulating the remaining auditory nerve fibers in the cochlea with electrical pulses. This thesis describs the electronic circuit design of

  1. Three-dimensional-fast imaging employing steady-state acquisition and T2-weighted fast spin-echo magnetic resonance sequences on visualization of cranial nerves Ⅲ-Ⅻ

    Institute of Scientific and Technical Information of China (English)

    2008-01-01

    @@ Because of the small diameter and complex anatomic course of the cranial nerves except for the optic nerve,mgeminal nerve,facial nerve,and cochlear and vestibular nerve,other cranial nerves are difficult to be visualized in magnetic resonance imaging (MRI) scanning with conventional thickness (5-10 mm).

  2. Influence of neural monitoring during thyroid surgery on nerve integrity and postoperative vocal function.

    Science.gov (United States)

    Engelsman, A F; Warhurst, S; Fraser, S; Novakovic, D; Sidhu, S B

    2018-06-01

    Integrity of the recurrent laryngeal nerve (RLN) and the external branch of the superior laryngeal nerve (EBSLN) can be checked by intraoperative nerve monitoring (IONM) after visualization. The aim of this study was to determine the prevalence and nature of voice dysfunction following thyroid surgery with routine IONM. Thyroidectomies were performed with routine division of strap muscles and nerve monitoring to confirm integrity of the RLN and EBSLN following dissection. Patients were assessed for vocal function before surgery and at 1 and 3 months after operation. Assessment included use of the Voice Handicap Index (VHI) 10, maximum phonation time, fundamental frequency, pitch range, harmonic to noise ratio, cepstral peak prominence and smoothed cepstral peak prominence. A total of 172 nerves at risk were analysed in 102 consecutive patients undergoing elective thyroid surgery. In 23·3 per cent of EBSLNs and 0·6 per cent of RLNs nerve identification required the assistance of IONM in addition to visualization. Nerve integrity was confirmed during surgery for 98·8 per cent of EBSLNs and 98·3 per cent of RLNs. There were no differences between preoperative and postoperative VHI-10 scores. Acoustic voice assessment showed small changes in maximum phonation time at 1 and 3 months after surgery. Where there is routine division of strap muscles, thyroidectomy using nerve monitoring confirmation of RLN and EBSLN function following dissection results in no clinically significant voice change.

  3. Sirviendo a los estudiantes sordos que tienen Los implantes cocleares. Hoja de consejos de PEPNet (Serving Deaf Students Who Have Cochlear Implants. PEPNet Tipsheet)

    Science.gov (United States)

    Clark, Catherine

    2010-01-01

    This version of "Serving Deaf Students Who Have Cochlear Implants. PEPNet Tipsheet," written in Spanish, describes how cochlear implants (CIs) work. CIs are complex electronic devices surgically implanted under the skin behind the ear. These devices utilize electrodes placed in the inner ear (the cochlea) to stimulate the auditory nerve of…

  4. Subclavian vein pacing and venous pressure waveform measurement for phrenic nerve monitoring during cryoballoon ablation of atrial fibrillation.

    Science.gov (United States)

    Ghosh, Justin; Singarayar, Suresh; Kabunga, Peter; McGuire, Mark A

    2015-06-01

    The phrenic nerves may be damaged during catheter ablation of atrial fibrillation. Phrenic nerve function is routinely monitored during ablation by stimulating the right phrenic nerve from a site in the superior vena cava (SVC) and manually assessing the strength of diaphragmatic contraction. However the optimal stimulation site, method of assessing diaphragmatic contraction, and techniques for monitoring the left phrenic nerve have not been established. We assessed novel techniques to monitor phrenic nerve function during cryoablation procedures. Pacing threshold and stability of phrenic nerve capture were assessed when pacing from the SVC, left and right subclavian veins. Femoral venous pressure waveforms were used to monitor the strength of diaphragmatic contraction. Stable capture of the left phrenic nerve by stimulation in the left subclavian vein was achieved in 96 of 100 patients, with a median capture threshold of 2.5 mA [inter-quartile range (IQR) 1.4-5.0 mA]. Stimulation of the right phrenic nerve from the subclavian vein was superior to stimulation from the SVC with lower pacing thresholds (1.8 mA IQR 1.4-3.3 vs. 6.0 mA IQR 3.4-8.0, P phrenic nerve palsy. The left phrenic nerve can be stimulated from the left subclavian vein. The subclavian veins are the optimal sites for phrenic nerve stimulation. Monitoring the femoral venous pressure waveform is a novel technique for detecting impending phrenic nerve damage. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2014. For permissions please email: journals.permissions@oup.com.

  5. The impact on post-operative shoulder function of intraoperative nerve monitoring of cranial nerve XI during modified radical neck dissection.

    Science.gov (United States)

    Lanišnik, Boštjan; Žitnik, Lidija; Levart, Primož; Žargi, Miha; Rodi, Zoran

    2016-12-01

    Intraoperative monitoring of the cranial nerve XI (CN XI) may decrease shoulder disability following modified radical neck dissection. Prospective study was designed comparing results of Constant Shoulder Score (CSS), Shoulder Pain and Disability Index (SPADI) and EMG score of the trapezius muscle (mT) before and after surgery. One side of the neck was monitored during surgery with intraoperative nerve monitor. EMG scores of the mT 6 months postoperatively were statistically better on monitored as compared to the non-monitored side of the neck (p = 0.041), while the differences of the CSS and SPADI were not statistically significant. Patients with better EMG scores of the mT at 6 weeks recuperated better and with smaller decrease of the CSS. Intraoperative monitoring is beneficial at the beginning of the surgeon's learning curve and in the process of familiarizing with anatomical variation of the CN XI.

  6. A two-microphone noise reduction system for cochlear implant users with nearby microphones. Part II: Performance Evaluation

    OpenAIRE

    Kompis, Martin; Bertram, Matthias; Senn, Pascal; Müller, Joachim; Pelizzone, Marco; Häusler, Rudolf

    2008-01-01

    Users of cochlear implants (auditory aids, which stimulate the auditory nerve electrically at the inner ear) often suffer from poor speech understanding in noise. We evaluate a small (intermicrophone distance 7 mm) and computationally inexpensive adaptive noise reduction system suitable for behind-the-ear cochlear implant speech processors. The system is evaluated in simulated and real, anechoic and reverberant environments. Results from simulations show improvements of 3.4 to 9.3 dB in signa...

  7. A comparison between neural response telemetry via cochleostomy or the round window approach in cochlear implantation.

    Science.gov (United States)

    Hamerschmidt, Rogério; Schuch, Luiz Henrique; Rezende, Rodrigo Kopp; Wiemes, Gislaine Richter Minhoto; Oliveira, Adriana Kosma Pires de; Mocellin, Marcos

    2012-01-01

    There are two techniques for cochlear implant (CI) electrode placement: cochleostomy and the round window (RW) approach. This study aims to compare neural response telemetry (NRT) results immediately after surgery to check for possible differences on auditory nerve stimulation between these two techniques. This is a prospective cross-sectional study. Twenty-three patients were enrolled. Six patients underwent surgery by cochleostomy and 17 had it through the RW approach. Mean charge units (MCU) for high frequency sounds: patients submitted to the RW approach had a mean value of 190.4 (± 29.2) while cochleostomy patients averaged 187.8 (± 32.7); p = 0.71. MCU for mid frequency sounds: patients submitted to the RW approach had a mean value of 192.5 (± 22) while cochleostomy patients averaged 178.5 (± 18.5); p = 0.23. MCU for low frequency sounds: patients submitted to the RW approach had a mean value of 183.3 (± 25) while cochleostomy patients averaged 163.8 (± 19.3); p = 0.19. This study showed no differences in the action potential of the distal portion of the auditory nerve in patients with multichannel cochlear implants submitted to surgery by cochleostomy or through the RW approach, using the implant itself to generate stimuli and record responses. Both techniques equally stimulate the cochlear nerve. Therefore, the choice of approach can be made based on the surgeon's own preference and experience.

  8. Automatic Model Generation Framework for Computational Simulation of Cochlear Implantation.

    Science.gov (United States)

    Mangado, Nerea; Ceresa, Mario; Duchateau, Nicolas; Kjer, Hans Martin; Vera, Sergio; Dejea Velardo, Hector; Mistrik, Pavel; Paulsen, Rasmus R; Fagertun, Jens; Noailly, Jérôme; Piella, Gemma; González Ballester, Miguel Ángel

    2016-08-01

    Recent developments in computational modeling of cochlear implantation are promising to study in silico the performance of the implant before surgery. However, creating a complete computational model of the patient's anatomy while including an external device geometry remains challenging. To address such a challenge, we propose an automatic framework for the generation of patient-specific meshes for finite element modeling of the implanted cochlea. First, a statistical shape model is constructed from high-resolution anatomical μCT images. Then, by fitting the statistical model to a patient's CT image, an accurate model of the patient-specific cochlea anatomy is obtained. An algorithm based on the parallel transport frame is employed to perform the virtual insertion of the cochlear implant. Our automatic framework also incorporates the surrounding bone and nerve fibers and assigns constitutive parameters to all components of the finite element model. This model can then be used to study in silico the effects of the electrical stimulation of the cochlear implant. Results are shown on a total of 25 models of patients. In all cases, a final mesh suitable for finite element simulations was obtained, in an average time of 94 s. The framework has proven to be fast and robust, and is promising for a detailed prognosis of the cochlear implantation surgery.

  9. Nerve canals at the fundus of the internal auditory canal on high-resolution temporal bone CT

    International Nuclear Information System (INIS)

    Ji, Yoon Ha; Youn, Eun Kyung; Kim, Seung Chul

    2001-01-01

    To identify and evaluate the normal anatomy of nerve canals in the fundus of the internal auditory canal which can be visualized on high-resolution temporal bone CT. We retrospectively reviewed high-resolution (1 mm thickness and interval contiguous scan) temporal bone CT images of 253 ears in 150 patients who had not suffered trauma or undergone surgery. Those with a history of uncomplicated inflammatory disease were included, but those with symptoms of vertigo, sensorineural hearing loss, or facial nerve palsy were excluded. Three radiologists determined the detectability and location of canals for the labyrinthine segment of the facial, superior vestibular and cochlear nerve, and the saccular branch and posterior ampullary nerve of the inferior vestibular nerve. Five bony canals in the fundus of the internal auditory canal were identified as nerve canals. Four canals were identified on axial CT images in 100% of cases; the so-called singular canal was identified in only 68%. On coronal CT images, canals for the labyrinthine segment of the facial and superior vestibular nerve were seen in 100% of cases, but those for the cochlear nerve, the saccular branch of the inferior vestibular nerve, and the singular canal were seen in 90.1%, 87.4% and 78% of cases, respectiveIy. In all detectable cases, the canal for the labyrinthine segment of the facial nerve was revealed as one which traversed anterolateralIy, from the anterosuperior portion of the fundus of the internal auditory canal. The canal for the cochlear nerve was located just below that for the labyrinthine segment of the facial nerve, while that canal for the superior vestibular nerve was seen at the posterior aspect of these two canals. The canal for the saccular branch of the inferior vestibular nerve was located just below the canal for the superior vestibular nerve, and that for the posterior ampullary nerve, the so-called singular canal, ran laterally or posteolateralIy from the posteroinferior aspect of

  10. Nerve canals at the fundus of the internal auditory canal on high-resolution temporal bone CT

    Energy Technology Data Exchange (ETDEWEB)

    Ji, Yoon Ha; Youn, Eun Kyung; Kim, Seung Chul [Sungkyunkwan Univ., School of Medicine, Seoul (Korea, Republic of)

    2001-12-01

    To identify and evaluate the normal anatomy of nerve canals in the fundus of the internal auditory canal which can be visualized on high-resolution temporal bone CT. We retrospectively reviewed high-resolution (1 mm thickness and interval contiguous scan) temporal bone CT images of 253 ears in 150 patients who had not suffered trauma or undergone surgery. Those with a history of uncomplicated inflammatory disease were included, but those with symptoms of vertigo, sensorineural hearing loss, or facial nerve palsy were excluded. Three radiologists determined the detectability and location of canals for the labyrinthine segment of the facial, superior vestibular and cochlear nerve, and the saccular branch and posterior ampullary nerve of the inferior vestibular nerve. Five bony canals in the fundus of the internal auditory canal were identified as nerve canals. Four canals were identified on axial CT images in 100% of cases; the so-called singular canal was identified in only 68%. On coronal CT images, canals for the labyrinthine segment of the facial and superior vestibular nerve were seen in 100% of cases, but those for the cochlear nerve, the saccular branch of the inferior vestibular nerve, and the singular canal were seen in 90.1%, 87.4% and 78% of cases, respectiveIy. In all detectable cases, the canal for the labyrinthine segment of the facial nerve was revealed as one which traversed anterolateralIy, from the anterosuperior portion of the fundus of the internal auditory canal. The canal for the cochlear nerve was located just below that for the labyrinthine segment of the facial nerve, while that canal for the superior vestibular nerve was seen at the posterior aspect of these two canals. The canal for the saccular branch of the inferior vestibular nerve was located just below the canal for the superior vestibular nerve, and that for the posterior ampullary nerve, the so-called singular canal, ran laterally or posteolateralIy from the posteroinferior aspect of

  11. Visualization of cranial nerves by MR cisternography using 3D FASE. Comparison with 2D FSE

    Energy Technology Data Exchange (ETDEWEB)

    Asakura, Hirofumi; Nakano, Satoru; Togami, Taro [Kagawa Medical School, Miki (Japan)] (and others)

    2001-03-01

    MR cisternography using 3D FASE was compared with that of 2D FSE in regard to visualization of normal cranial nerves. In a phantom study, contrast-to-noise ratio (C/N) of fine structures was better in 3D FASE images than in 2D FSE. In clinical cases, visualization of trigeminal nerve, abducent nerve, and facial/vestibulo-cochlear nerve were evaluated. Each cranial nerve was visualized better in 3D FASE images than in 2D FSE, with a significant difference (p<0.05). (author)

  12. Visualization of cranial nerves by MR cisternography using 3D FASE. Comparison with 2D FSE

    International Nuclear Information System (INIS)

    Asakura, Hirofumi; Nakano, Satoru; Togami, Taro

    2001-01-01

    MR cisternography using 3D FASE was compared with that of 2D FSE in regard to visualization of normal cranial nerves. In a phantom study, contrast-to-noise ratio (C/N) of fine structures was better in 3D FASE images than in 2D FSE. In clinical cases, visualization of trigeminal nerve, abducent nerve, and facial/vestibulo-cochlear nerve were evaluated. Each cranial nerve was visualized better in 3D FASE images than in 2D FSE, with a significant difference (p<0.05). (author)

  13. Automatic Model Generation Framework for Computational Simulation of Cochlear Implantation

    DEFF Research Database (Denmark)

    Mangado Lopez, Nerea; Ceresa, Mario; Duchateau, Nicolas

    2016-01-01

    . To address such a challenge, we propose an automatic framework for the generation of patient-specific meshes for finite element modeling of the implanted cochlea. First, a statistical shape model is constructed from high-resolution anatomical μCT images. Then, by fitting the statistical model to a patient......'s CT image, an accurate model of the patient-specific cochlea anatomy is obtained. An algorithm based on the parallel transport frame is employed to perform the virtual insertion of the cochlear implant. Our automatic framework also incorporates the surrounding bone and nerve fibers and assigns......Recent developments in computational modeling of cochlear implantation are promising to study in silico the performance of the implant before surgery. However, creating a complete computational model of the patient's anatomy while including an external device geometry remains challenging...

  14. In-vitro characterization of a cochlear implant system for recording of evoked compound action potentials

    Science.gov (United States)

    2012-01-01

    Background Modern cochlear implants have integrated recording systems for measuring electrically evoked compound action potentials of the auditory nerve. The characterization of such recording systems is important for establishing a reliable basis for the interpretation of signals acquired in vivo. In this study we investigated the characteristics of the recording system integrated into the MED-EL PULSARCI100 cochlear implant, especially its linearity and resolution, in order to develop a mathematical model describing the recording system. Methods In-vitro setup: The cochlear implant, including all attached electrodes, was fixed in a tank of physiologic saline solution. Sinusoidal signals of the same frequency but with different amplitudes were delivered via a signal generator for measuring and recording on a single electrode. Computer simulations: A basic mathematical model including the main elements of the recording system, i.e. amplification and digitalization stage, was developed. For this, digital output for sinusoidal input signals of different amplitudes were calculated using in-vitro recordings as reference. Results Using an averaging of 100 measurements the recording system behaved linearly down to approximately -60 dB of the input signal range. Using the same method, a system resolution of 10 μV was determined for sinusoidal signals. The simulation results were in very good agreement with the results obtained from in-vitro experiments. Conclusions The recording system implemented in the MED-EL PULSARCI100 cochlear implant for measuring the evoked compound action potential of the auditory nerve operates reliably. The developed mathematical model provides a good approximation of the recording system. PMID:22531599

  15. A Model-Based Approach for Separating the Cochlear Microphonic from the Auditory Nerve Neurophonic in the Ongoing Response Using Electrocochleography

    Directory of Open Access Journals (Sweden)

    Tatyana E. Fontenot

    2017-10-01

    Full Text Available Electrocochleography (ECochG is a potential clinically valuable technique for predicting speech perception outcomes in cochlear implant (CI recipients, among other uses. Current analysis is limited by an inability to quantify hair cell and neural contributions which are mixed in the ongoing part of the response to low frequency tones. Here, we used a model based on source properties to account for recorded waveform shapes and to separate the combined signal into its components. The model for the cochlear microphonic (CM was a sinusoid with parameters for independent saturation of the peaks and the troughs of the responses. The model for the auditory nerve neurophonic (ANN was the convolution of a unit potential and population cycle histogram with a parameter for spread of excitation. Phases of the ANN and CM were additional parameters. The average cycle from the ongoing response was the input, and adaptive fitting identified CM and ANN parameters that best reproduced the waveform shape. Test datasets were responses recorded from the round windows of CI recipients, from the round window of gerbils before and after application of neurotoxins, and with simulated signals where each parameter could be manipulated in isolation. Waveforms recorded from 284 CI recipients had a variety of morphologies that the model fit with an average r2 of 0.97 ± 0.058 (standard deviation. With simulated signals, small systematic differences between outputs and inputs were seen with some variable combinations, but in general there were limited interactions among the parameters. In gerbils, the CM reported was relatively unaffected by the neurotoxins. In contrast, the ANN was strongly reduced and the reduction was limited to frequencies of 1,000 Hz and lower, consistent with the range of strong neural phase-locking. Across human CI subjects, the ANN contribution was variable, ranging from nearly none to larger than the CM. Development of this model could provide a

  16. Preventing lower cranial nerve injuries during fourth ventricle tumor resection by utilizing intraoperative neurophysiological monitoring.

    Science.gov (United States)

    Jahangiri, Faisal R; Minhas, Mazhar; Jane, John

    2012-12-01

    We present two cases illustrating the benefit of utilizing intraoperative neurophysiological monitoring (IONM) for prevention of injuries to the lower cranial nerves during fourth ventricle tumor resection surgeries. Multiple cranial nerve nuclei are located on the floor of the fourth ventricle with a high risk of permanent damage. Two male patients (ages 8 and 10 years) presented to the emergency department and had brain magnetic resonance imaging (MRI) scans showing brainstem/fourth ventricle tumors. During surgery, bilateral posterior tibial and median nerve somatosensory evoked potentials (SSEPs); four-limb and cranial nerves transcranial electrical motor evoked potentials (TCeMEPs); brainstem auditory evoked responses (BAERs); and spontaneous electromyography (s-EMG) were recorded. Electromyography (EMG) was monitored bilaterally from cranial nerves V VII, IX, X, XI, and XII. Total intravenous anesthesia was used. Neuromuscular blockade was used only for initial intubation. Pre-incision baselines were obtained with good morphology of waveforms. After exposure the floor of the fourth ventricle was mapped by triggered-EMG (t-EMG) using 0.4 to 1.0 mA. In both patients the tumor was entangled with cranial nerves VII to XII on the floor of the fourth ventricle. The surgeon made the decision not to resect the tumor in one case and limited the resection to 70% of the tumor in the second case on the basis of neurophysiological monitoring. This decision was made to minimize any post-operative neurological deficits due to surgical manipulation of the tumor involving the lower cranial nerves. Intraoperative spontaneous and triggered EMG was effectively utilized in preventing injuries to cranial nerves during surgical procedures. All signals remained stable during the surgical procedure. Postoperatively both patients were well with no additional cranial nerve weakness. At three months follow-up, the patients continued to have no deficits.

  17. [Cochlear implant in children: rational, indications and cost/efficacy].

    Science.gov (United States)

    Martini, A; Bovo, R; Trevisi, P; Forli, F; Berrettini, S

    2013-06-01

    A cochlear implant (CI) is a partially implanted electronic device that can help to provide a sense of sound and support speech to severely to profoundly hearing impaired patients. It is constituted by an external portion, that usually sits behind the ear and an internal portion surgically placed under the skin. The external components include a microphone connected to a speech processor that selects and arranges sounds pucked up by the microphone. This is connected to a transmitter coil, worn on the side of the head, which transmits data to an internal receiver coil placed under the skin. The received data are delivered to an array of electrodes that are surgically implanted within the cochlea. The primary neural targets of the electrodes are the spiral ganglion cells which innervate fibers of the auditory nerve. When the electrodes are activated by the signal, they send a current along the auditory nerve and auditory pathways to the auditory cortex. Children and adults who are profoundly or severely hearing impaired can be fitted with cochlear implants. According to the Food and Drug Administration, approximately 188,000 people worldwide have received implants. In Italy it is extimated that there are about 6-7000 implanted patients, with an average of 700 CI surgeries per year. Cochlear implantation, followed by intensive postimplantation speech therapy, can help young children to acquire speech, language, and social skills. Early implantation provides exposure to sounds that can be helpful during the critical period when children learn speech and language skills. In 2000, the Food and Drug Administration lowered the age of eligibility to 12 months for one type of CI. With regard to the results after cochlear implantation in relation to early implantation, better linguistic results are reported in children implanted before 12 months of life, even if no sufficient data exist regarding the relation between this advantage and the duration of implant use and how long

  18. Prospective Evaluation of Electromyography-Guided Phrenic Nerve Monitoring During Superior Vena Cava Isolation to Anticipate Phrenic Nerve Injury.

    Science.gov (United States)

    Miyazaki, Shinsuke; Ichihara, Noboru; Nakamura, Hiroaki; Taniguchi, Hiroshi; Hachiya, Hitoshi; Araki, Makoto; Takagi, Takamitsu; Iwasawa, Jin; Kuroi, Akio; Hirao, Kenzo; Iesaka, Yoshito

    2016-04-01

    Right phrenic nerve injury (PNI) is a major concern during superior vena cava (SVC) isolation due to the anatomical close proximity. The functional and histological severity of PNI parallels the degree of the reduction in the compound motor action potential (CMAP) amplitude. This study aimed to evaluate the feasibility of monitoring CMAPs during SVC isolation to anticipate PNI during atrial fibrillation (AF) ablation. Thirty-nine paroxysmal AF patients were prospectively enrolled. Radiofrequency energy was delivered point-by-point for 30 seconds with 20 W until eliminating all SVC potentials after the pulmonary vein isolation. Right diaphragmatic CMAPs were obtained from modified surface electrodes by pacing from the right subclavian vein. Radiofrequency applications were applied without fluoroscopy under CMAP monitoring at sites with phrenic nerve capture by high output pacing. Electrical SVC isolation was successfully achieved with a mean of 9.4 ± 3.3 applications in all patients. In 3 (7.5%) patients, the SVC was isolated without radiofrequency delivery at phrenic nerve capture sites. Among a total of 346 applications in the remaining 36 patients, 71 (20.5%) were delivered while monitoring CMAPs. In 1 (1.4%) application, the RF application was interrupted due to a decrease in the CMAP amplitude. However, no PNI was detected on fluoroscopy, and the decreased amplitude recovered spontaneously. The remaining 70 (98.6%) applications exhibited no significant changes in the CMAP amplitude throughout the applications (from 1.01 ± 0.47 to 0.98 ± 0.45 mV, P = 0.383). Stable right diaphragmatic CMAPs could be obtained, and monitoring CMAPs might be useful for anticipating right PNI during SVC isolation. © 2016 Wiley Periodicals, Inc.

  19. Technological, biological, and acoustical constraints to music perception in cochlear implant users.

    Science.gov (United States)

    Limb, Charles J; Roy, Alexis T

    2014-02-01

    Despite advances in technology, the ability to perceive music remains limited for many cochlear implant users. This paper reviews the technological, biological, and acoustical constraints that make music an especially challenging stimulus for cochlear implant users, while highlighting recent research efforts to overcome these shortcomings. The limitations of cochlear implant devices, which have been optimized for speech comprehension, become evident when applied to music, particularly with regards to inadequate spectral, fine-temporal, and dynamic range representation. Beyond the impoverished information transmitted by the device itself, both peripheral and central auditory nervous system deficits are seen in the presence of sensorineural hearing loss, such as auditory nerve degeneration and abnormal auditory cortex activation. These technological and biological constraints to effective music perception are further compounded by the complexity of the acoustical features of music itself that require the perceptual integration of varying rhythmic, melodic, harmonic, and timbral elements of sound. Cochlear implant users not only have difficulty perceiving spectral components individually (leading to fundamental disruptions in perception of pitch, melody, and harmony) but also display deficits with higher perceptual integration tasks required for music perception, such as auditory stream segregation. Despite these current limitations, focused musical training programs, new assessment methods, and improvements in the representation and transmission of the complex acoustical features of music through technological innovation offer the potential for significant advancements in cochlear implant-mediated music perception. Copyright © 2013 Elsevier B.V. All rights reserved.

  20. Neurotrophic treatment of the degenerating auditory nerve; cochlear implants in deafened guinea pigs

    NARCIS (Netherlands)

    Agterberg, M.J.H.

    2009-01-01

    To date, the cochlear implant is the most successful sensorineural prosthesis. The device consists of a small array with a number of electrodes implanted in the cochlea of profoundly hearing impaired people. Some people with an implant are able to use the telephone. Unfortunately, others hardly

  1. Development of micro-electromechanical system (MEMS) cochlear biomodel

    Energy Technology Data Exchange (ETDEWEB)

    Ngelayang, Thailis Bounya Anak; Latif, Rhonira [Faculty of Electronic and Computer Engineering, Universiti Teknikal Malaysia Melaka, Hang Tuah Jaya, 76100 Durian Tunggal, Melaka (Malaysia)

    2015-05-15

    Human cochlear is undeniably one of the most amazing organs in human body. The functional mechanism is very unique in terms of its ability to convert the sound waves in the form of mechanical vibrations into the electrical nerve impulses. It is known that the normal human auditory system can perceive the audible frequency range between 20 Hz to 20 kHz. Scientists have conducted several researches trying to build the artificial basilar membrane in the human cochlea (cochlear biomodel). Micro-electromechanical system (MEMS) is one of the potential inventions that have the ability to mimic the active behavior of the basilar membrane. In this paper, an array of MEMS bridge beams that are mechanically sensitive to the perceived audible frequency has been proposed. An array of bridge bridge beams with 0.5 µm thickness and length varying from 200 µm to 2000 µm have been designed operate within the audible frequency range. In the bridge beams design, aluminium (Al), copper (Cu), tantalum (Ta) and platinum (Pt) have considered as the material for the bridge beam structure. From the finite element (FE) and lumped element (LE) models of the MEMS bridge beams, platinum has been found to be the best material for the cochlear biomodel design, closely mimicking the basilar membrane.

  2. Development of micro-electromechanical system (MEMS) cochlear biomodel

    International Nuclear Information System (INIS)

    Ngelayang, Thailis Bounya Anak; Latif, Rhonira

    2015-01-01

    Human cochlear is undeniably one of the most amazing organs in human body. The functional mechanism is very unique in terms of its ability to convert the sound waves in the form of mechanical vibrations into the electrical nerve impulses. It is known that the normal human auditory system can perceive the audible frequency range between 20 Hz to 20 kHz. Scientists have conducted several researches trying to build the artificial basilar membrane in the human cochlea (cochlear biomodel). Micro-electromechanical system (MEMS) is one of the potential inventions that have the ability to mimic the active behavior of the basilar membrane. In this paper, an array of MEMS bridge beams that are mechanically sensitive to the perceived audible frequency has been proposed. An array of bridge bridge beams with 0.5 µm thickness and length varying from 200 µm to 2000 µm have been designed operate within the audible frequency range. In the bridge beams design, aluminium (Al), copper (Cu), tantalum (Ta) and platinum (Pt) have considered as the material for the bridge beam structure. From the finite element (FE) and lumped element (LE) models of the MEMS bridge beams, platinum has been found to be the best material for the cochlear biomodel design, closely mimicking the basilar membrane

  3. A Case of Cochlear Implantation in Bromate-Induced Bilateral Sudden Deafness.

    Science.gov (United States)

    Eom, Tae-Ho; Lee, Sungsu; Cho, Hyong-Ho; Cho, Yong-Beom

    2015-04-01

    Despite the well-established nature of bromate-induced ototoxicity, cochlear implantation after bromate intoxication has been rarely documented. We hereby present a case of a 51-year-old female deafened completely after bromate ingestion. Her hearing was not restored by systemic steroid treatment and hearing aids were of no use. A cochlear implantation was performed on her right ear 3 months after the bromate ingestion. In bromate intoxication cases, early monitoring of hearing level is necessary and other drugs with potential ototoxicity should be avoided. The outcome of cochlear implantation was excellent in this case of bromate-induced deafness.

  4. Children using Cochlear Implants Capitalize on Acoustical Hearing for Music Perception

    Directory of Open Access Journals (Sweden)

    Talar eHopyan

    2012-10-01

    Full Text Available Cochlear implants (CIs electrically stimulate the auditory nerve providing children who are deaf with access to speech and music. Because of device limitations, it was hypothesized that children using CIs develop abnormal perception of musical cues. Perception of pitch and rhythm as well as memory for music was measured by the children’s version of the Montreal Battery of Amusia (MBEA in 23 unilateral CI users and 22 age-matched children with normal hearing. Children with CIs were less accurate than their normal hearing peers (p<0.05. CI users were best able to discern rhythm changes (p < .01 and to remember musical pieces (p < .01. Contrary to expectations, abilities to hear cues in music improved as the age at implantation increased (p < .01. Further analyses revealed that this was because the children implanted at older ages also had better low frequency hearing prior to cochlear implantation and were able to use this hearing prior to cochlear implantation by wearing hearing aids. Access to early acoustical hearing in the lower frequency ranges appears to establish a base for music perception, which can be accessed with later electrical CI hearing.

  5. Cranial nerve monitoring during subpial dissection in temporomesial surgery.

    Science.gov (United States)

    Ortler, Martin; Fiegele, Thomas; Walser, Gerald; Trinka, Eugen; Eisner, Wilhelm

    2011-06-01

    Cranial nerves (CNs) crossing between the brainstem and skull base at the level of the tentorial hiatus may be at risk in temporomesial surgery involving subpial dissection and/or tumorous growth leading to distorted anatomy. We aimed to identify the surgical steps most likely to result in CN damage in this type of surgery. Electromyographic responses obtained with standard neuromonitoring techniques and a continuous free-running EMG were graded as either contact activity or pathological spontaneous activity (PSA) during subpial resection of temporomesial structures in 16 selective amygdalohippocampectomy cases. Integrity of peripheral motor axons was tested by transpial/transarachnoidal electrical stimulation while recording compound muscle action potentials from distal muscle(s). Continuous EMG showed pathological activity in five (31.2%) patients. Nine events with PSA (slight activity, n = 8; strong temporary activity, n = 1) were recorded. The oculomotor nerve was involved three times, the trochlear nerve twice, the facial nerve once, and all monitored nerves on three occasions. Surgical maneuvers associated with PSA were the resection of deep parts of the hippocampus and parahippocampal gyrus (CN IV, twice; CN III, once), lining with or removing cotton patties from the resection cavity (III, twice; all channels, once) and indirect exertion of tension on the intact pia/arachnoid of the uncal region while mobilizing the hippocampus and parahippocampal gyrus en bloc (all channels, once; III, once). CMAPs were observed at 0.3 mA in two patients and at 0.6 mA in one patient, and without registering the exact amount of intensity in three patients. The most dangerous steps leading to cranial nerve damage during mesial temporal lobe surgery are the final stages of the intervention while the resection is being completed in the deep posterior part and the resection cavity is being lined with patties. Distant traction may act on nerves crossing the tentorial

  6. α-Synuclein deficiency and efferent nerve degeneration in the mouse cochlea: a possible cause of early-onset presbycusis.

    Science.gov (United States)

    Park, S N; Back, S A; Choung, Y H; Kim, H L; Akil, O; Lustig, L R; Park, K H; Yeo, S W

    2011-11-01

    Efferent nerves under the outer hair cells (OHCs) play a role in the protection of these cells from loud stimuli. Previously, we showed that cochlear α-synuclein expression is localized to efferent auditory synapses at the base of the OHCs. To prove our hypothesis that α-synuclein deficiency and efferent auditory deficit might be a cause of hearing loss, we compared the morphology of efferent nerve endings and α-synuclein expression within the cochleae of two mouse models of presbycusis. Comparative animal study of presbycusis. The C57BL/6J(C57) mouse strain, a well-known model of early-onset hearing loss, and the CBA mouse strain, a model of relatively late-onset hearing loss, were examined. Auditory brainstem responses and distortion product otoacoustic emissions were recorded, and cochlear morphology with efferent nerve ending was compared. Western blotting was used to examine α-synuclein expression in the cochlea. Compared with CBA mice, C57 mice showed earlier onset high-frequency hearing loss and decreased function in OHCs, especially within high-frequency regions. C57 mice demonstrated more severe pathologic changes within the cochlea, particularly within the basal turn, than CBA mice of the same age. Weaker α-synuclein and synaptophysin expression in the efferent nerve endings and cochlear homogenates in C57 mice was observed. Our results support the hypothesis that efferent nerve degeneration, possibly due to differential α-synuclein expression, is a potential cause of early-onset presbycusis. Further studies at the cellular level are necessary to verify our results. Copyright © 2011 Elsevier Ireland Ltd and the Japan Neuroscience Society. All rights reserved.

  7. Anterior Inferior Cerebellar Arteries Juxtaposed with the Internal Acoustic Meatus and Their Relationship to the Cranial Nerve VII/VIII Complex.

    Science.gov (United States)

    Alonso, Fernando; Kassem, Mohammad W; Iwanaga, Joe; Oskouian, Rod J; Loukas, Marios; Demerdash, Amin; Tubbs, R Shane

    2017-08-16

    Vascular loops in the cerebellopontine angle (CPA) and their relationship to cranial nerves have been used to explain neurological symptoms. The anterior inferior cerebellar artery (AICA) has variable branches producing vascular loops that can compress the facial cranial nerve (CN) VII and vestibulocochlear (CN VIII) nerves. AICA compression of the facial-vestibulocochlear nerve complex can lead to various clinical presentations, including hemifacial spasm (HFS), tinnitus, and hemiataxia. The formation of arterial loops inside or outside of the internal auditory meatus (IAM) can cause abutment or compression of CN VII and CN VIII. Twenty-five (50 sides) fresh adult cadavers underwent dissection of the cerebellopontine angle in the supine position. In regard to relationships between the AICA and the nerves of the facial/vestibulocochlear complex, 33 arteries (66%) traveled in a plane between the facial/nervus intermedius nerves and the cochlear and vestibular nerves. Five arteries (10%) traveled below the CN VII/VIII complex, six (12%) traveled posterior to the nerve complex, four (8%) formed a semi-circle around the upper half of the nerve complex, and two (4%) traveled between and partially separated the nervus intermedius and facial nerve proper. Our study found that the majority of AICA will travel in a plane between the facial/nervus intermedius nerves and the cochlear and vestibular nerves. Although the relationship between the AICA and porus acusticus and AICA and the nerves of the CN VII/VIII complex are variable, based on our findings, some themes exist. Surgeons should consider these with approaches to the cerebellopontine angle.

  8. [Dynamics of lagophthalmos depending on facial nerve repair and its intraoperative monitoring in neurosurgical patients].

    Science.gov (United States)

    Tabachnikova, T V; Serova, N K; Shimansky, V N

    2014-01-01

    Over 200 patients with acoustic neuromas and over 100 patients with posterior cranial fossa meningiomas are annually operated on at the N.N. Burdenko Neurosurgical Institute. Intraoperative monitoring of the facial nerve function is used in most patients with tumors of the posterior cranial fossa to identify the facial nerve in the surgical wound. If the anatomical integrity of the facial nerve in the cranial cavity cannot be retained, facial nerve repair is performed to restore the facial muscle function. Intraoperative electrical stimulation of the facial nerve has a great prognostic significance to evaluate the dynamics of lagophthalmos in the late postoperative period and to select the proper method for lagophthalmos correction. When the facial nerve was reinnervated by the descending branch or trunk of the hypoglossal nerve, sufficient eyelid closure was observed only in 3 patients out of 17.

  9. Demonstration of ipsilateral brain activation by noise in patients profoundly deaf with cochlear implant, or unilaterally deaf

    International Nuclear Information System (INIS)

    Herzog, H.; Wieler, H.; Morgenstern, C.; Lipman, J.; Langen, K.-J.; Schmid, A.; Rota, E.; Patton, D.; Feinendegen, L.F.

    1986-01-01

    Two groups of patients with hearing handicaps have been investigated with PET and F-18-2-FDG. Since these patients were unilaterally deaf or profoundly deaf with a cochlear implant installed, monaural stimulation was possible excluding any effects of bone conduction to the contralateral ear. White noise was used as acoustic stimulus in unilaterally deaf patients. The peripheral auditory nerve of cochlear implant patients was stimulated by electrical impulses which were encoded from music or a 4-tone mixture by an electronic speech processor. The non-music stimuli were chosen to avoid associative cortical reactions. In both groups response to the stimuli by increase of glucose consumption (LCMRglc) was found not only in the contralateral primary auditory cortex as expected from neuroanatomical knowledge, but also in the ipsilateral auditory cortex. Furthermore there was no correlation between the hemisphere showing increased LCMRglc and the side of stimulation or the type of stimulus. The similarity of results obtained in both groups by acoustical and electrical stimulation of the auditory nerve suggests that this kind of measurement might be a tool to predict or check the performance of a cochlear implant in a profoundly deaf patient. The finding of increased LCMRglc in the area of the normal auditory cortex in patients profoundly deaf since birth contradicts the hypothesis of degeneration of this cortical center in such patients. (Author)

  10. 3D CISS, 3D MP-PAGE and 2D TSE for MRI prior to Cochlear implantation

    International Nuclear Information System (INIS)

    Seitz, J.; Held, P.; Voelk, M.; Lenhart, M.; Strotzer, M.; Waldeck, A.

    2000-01-01

    Purpose: The aim of this study was to determine the presurgical predictive value of high resolution MRI in patients scheduled for chochlear implantation. Method and material: The presurgical MRI (3D CISS, 3D MP-RAGE with and without i.v. contrast medium, 2D TSE) findings of 54 patients and the intraoperative situation reported by the surgeon were compared retrospectively. The surgical and functional success of the cochlear implantation was evaluated. Results: We found a high degree of correlation between MRI and intraoperative findings concerning the patency of the whole cochlea and anomalies as well as in the diagnosis of pathology of the cochlear, vestibular and facial nerves and in anomalies of the internal auditory canal. However, in four out of 54 patients there was a false negative prediction regarding the patency of the cochlea. The sensitivity was 50% (4/8), the specificity 100% (46/46). Concerning the surgical success the accuracy was 100%. In all patients MRI gave sufficient anatomical information to the surgeon concerning the jugular bulb and the facial nerve. Conclusion: A high-resolution MRI protocol consisting of coronal 2D T2w TSE, 3D T2*w transverse CISS; plain and contrast enhanced sagittal T1w 3D MP-RAGE is recommended for the evaluation of candidates scheduled for cochlear implantation. (orig.) [de

  11. The consequences of neural degeneration regarding optimal cochlear implant position in scala tympani: a model approach.

    Science.gov (United States)

    Briaire, Jeroen J; Frijns, Johan H M

    2006-04-01

    Cochlear implant research endeavors to optimize the spatial selectivity, threshold and dynamic range with the objective of improving the speech perception performance of the implant user. One of the ways to achieve some of these goals is by electrode design. New cochlear implant electrode designs strive to bring the electrode contacts into close proximity to the nerve fibers in the modiolus: this is done by placing the contacts on the medial side of the array and positioning the implant against the medial wall of scala tympani. The question remains whether this is the optimal position for a cochlea with intact neural fibers and, if so, whether it is also true for a cochlea with degenerated neural fibers. In this study a computational model of the implanted human cochlea is used to investigate the optimal position of the array with respect to threshold, dynamic range and spatial selectivity for a cochlea with intact nerve fibers and for degenerated nerve fibers. In addition, the model is used to evaluate the predictive value of eCAP measurements for obtaining peri-operative information on the neural status. The model predicts improved threshold, dynamic range and spatial selectivity for the peri-modiolar position at the basal end of the cochlea, with minimal influence of neural degeneration. At the apical end of the array (1.5 cochlear turns), the dynamic range and the spatial selectivity are limited due to the occurrence of cross-turn stimulation, with the exception of the condition without neural degeneration and with the electrode array along the lateral wall of scala tympani. The eCAP simulations indicate that a large P(0) peak occurs before the N(1)P(1) complex when the fibers are not degenerated. The absence of this peak might be used as an indicator for neural degeneration.

  12. Comparison between bilateral cochlear implants and Neurelec Digisonic(®) SP Binaural cochlear implant: speech perception, sound localization and patient self-assessment.

    Science.gov (United States)

    Bonnard, Damien; Lautissier, Sylvie; Bosset-Audoit, Amélie; Coriat, Géraldine; Beraha, Max; Maunoury, Antoine; Martel, Jacques; Darrouzet, Vincent; Bébéar, Jean-Pierre; Dauman, René

    2013-01-01

    An alternative to bilateral cochlear implantation is offered by the Neurelec Digisonic(®) SP Binaural cochlear implant, which allows stimulation of both cochleae within a single device. The purpose of this prospective study was to compare a group of Neurelec Digisonic(®) SP Binaural implant users (denoted BINAURAL group, n = 7) with a group of bilateral adult cochlear implant users (denoted BILATERAL group, n = 6) in terms of speech perception, sound localization, and self-assessment of health status and hearing disability. Speech perception was assessed using word recognition at 60 dB SPL in quiet and in a 'cocktail party' noise delivered through five loudspeakers in the hemi-sound field facing the patient (signal-to-noise ratio = +10 dB). The sound localization task was to determine the source of a sound stimulus among five speakers positioned between -90° and +90° from midline. Change in health status was assessed using the Glasgow Benefit Inventory and hearing disability was evaluated with the Abbreviated Profile of Hearing Aid Benefit. Speech perception was not statistically different between the two groups, even though there was a trend in favor of the BINAURAL group (mean percent word recognition in the BINAURAL and BILATERAL groups: 70 vs. 56.7% in quiet, 55.7 vs. 43.3% in noise). There was also no significant difference with regard to performance in sound localization and self-assessment of health status and hearing disability. On the basis of the BINAURAL group's performance in hearing tasks involving the detection of interaural differences, implantation with the Neurelec Digisonic(®) SP Binaural implant may be considered to restore effective binaural hearing. Based on these first comparative results, this device seems to provide benefits similar to those of traditional bilateral cochlear implantation, with a new approach to stimulate both auditory nerves. Copyright © 2013 S. Karger AG, Basel.

  13. Diversity in cochlear morphology and its influence on cochlear implant electrode position

    NARCIS (Netherlands)

    Marel, K.S. van der; Briaire, J.J.; Wolterbeek, R..; Snel-Bongers, J.; Verbist, B.M.; Frijns, J.H.

    2014-01-01

    To define a minimal set of descriptive parameters for cochlear morphology and study its influence on the cochlear implant electrode position in relation to surgical insertion distance.Cochlear morphology and electrode position were analyzed using multiplanar reconstructions of the pre- and

  14. Experience of monitoring the recurrent laryngeal nerve in thyroid surgery with endotracheal intubation

    Directory of Open Access Journals (Sweden)

    Liang Feng

    2017-01-01

    Full Text Available Purpose:To analysis clinical experience of applying recurrent laryngeal monitoring endotracheal tube (NIM EMG Endotracheal Tube in the surgery of thyroid. Method: A retrospective analysis of 84 patients who underwent endotracheal intubation laryngeal nerve monitoring by thyroid surgery in the Chinese-Japanese Friendship Hospital of Jilin University from March to December in 2015. To summarize the experience of intubation with NIM EMG Endotracheal Tube. Result 77 (91.7%had initial intubation achievement in the 84 patients.FROM the 77 cases we had gotten s atisfactory nerve monitoring signal.Whereas there are 7 cases (8.3% appear abnormal EMG or signal missing, in the 7 cases there is one which being intubated too deep, 3 cases which being intubated too shallow and 3 cases with malrotation intubation.Conclusion: We got the satisfactory signals after adjust1ing the tube by using the visual laryngoscope.

  15. Usefulness of intraoperative electromyographic monitoring of oculomotor and abducens nerves during skull base surgery.

    Science.gov (United States)

    Li, Zi-Yi; Li, Ming-Chu; Liang, Jian-Tao; Bao, Yu-Hai; Chen, Ge; Guo, Hong-Chuan; Ling, Feng

    2017-10-01

    Intraoperative neurophysiologic monitoring of the extraocular cranial nerve (EOCN) is not commonly performed because of technical difficulty and risk, reliability of the result and predictability of the postoperative function of the EOCN. We performed oculomotor nerve (CN III) and abducens nerve (CN VI) intraoperative monitoring in patients with skull base surgery by recording the spontaneous muscle activity (SMA) and compound muscle action potential (CMAP). Two types of needle electrodes of different length were percutaneously inserted into the extraocular muscles with the free-hand technique. We studied the relationships between the SMA and CMAP and postoperative function of CN III and CN VI. A total of 23 patients were included. Nineteen oculomotor nerves and 22 abducens nerves were monitored during surgery, respectively. Neurotonic discharge had a positive predictive value of less than 50% and negative predictive value of more than 80% for postoperative CN III and CN VI dysfunction. The latency of patients with postoperative CN III dysfunction was 2.79 ± 0.13 ms, longer than that with intact CN III function (1.73 ± 0.11 ms). One patient had transient CN VI dysfunction, whose CMAP latency (2.54 ms) was longer than that of intact CN VI function (2.11 ± 0.38 ms). There was no statistically significant difference between patients with paresis and with intact function. The method of intraoperative monitoring of EOCNs described here is safe and useful to record responses of SMA and CMAP. Neurotonic discharge seems to have limited value in predicting the postoperative function of CN III and CN VI. The onset latency of CMAP longer than 2.5 ms after tumor removal is probably relevant to postoperative CN III and CN VI dysfunction. However, a definite quantitative relationship has not been found between the amplitude and stimulation intensity of CMAP and the postoperative outcome of CN III and CN VI.

  16. Auditory brainstem activity and development evoked by apical versus basal cochlear implant electrode stimulation in children.

    Science.gov (United States)

    Gordon, K A; Papsin, B C; Harrison, R V

    2007-08-01

    The role of apical versus basal cochlear implant electrode stimulation on central auditory development was examined. We hypothesized that, in children with early onset deafness, auditory development evoked by basal electrode stimulation would differ from that evoked more apically. Responses of the auditory nerve and brainstem, evoked by an apical and a basal implant electrode, were measured over the first year of cochlear implant use in 50 children with early onset severe to profound deafness who used hearing aids prior to implantation. Responses at initial stimulation were of larger amplitude and shorter latency when evoked by the apical electrode. No significant effects of residual hearing or age were found on initial response amplitudes or latencies. With implant use, responses evoked by both electrodes showed decreases in wave and interwave latencies reflecting decreased neural conduction time through the brainstem. Apical versus basal differences persisted with implant experience with one exception; eIII-eV interlatency differences decreased with implant use. Acute stimulation shows prolongation of basally versus apically evoked auditory nerve and brainstem responses in children with severe to profound deafness. Interwave latencies reflecting neural conduction along the caudal and rostral portions of the brainstem decreased over the first year of implant use. Differences in neural conduction times evoked by apical versus basal electrode stimulation persisted in the caudal but not rostral brainstem. Activity-dependent changes of the auditory brainstem occur in response to both apical and basal cochlear implant electrode stimulation.

  17. REMOTE BIOSENSOR FOR IN SITU MONITORING OF ORGANOPHOSPHATE NERVE AGENTS. (R823663)

    Science.gov (United States)

    A remote electrochemical biosensor for field monitoring of organophosphate nerve agents is described. The new sensor relies on the coupling of the effective biocatalytic action of organophosphorus hydrolase (OPH) with a submersible amperometric probe design. This combination resu...

  18. Intra-operative monitoring of the common peroneal nerve during total knee replacement.

    Science.gov (United States)

    Unwin, A J; Thomas, M

    1994-01-01

    We present a method allowing intra-operative monitoring of the common peroneal nerve during total knee arthroplasty using a magnetic stimulator. Previous reports have shown no pre-operative method successful in selecting those patients prone to develop a post-operative palsy. The device, placed beneath the lumbar spine, stimulates the cauda equina; common peroneal nerve function is assessed via the response in extensor digitorum brevis. There is a loss of signal from the nerve with the use of a tourniquet 25 min following its application. The protocol therefore requires that a tourniquet is used at least only for fixation of the prosthetic components. The method is quick, safe, non-invasive and reproducible, and is of use both in at-risk patients and in research work. Images Figure 6. PMID:7837197

  19. Noise-induced cochlear synaptopathy in rhesus monkeys (Macaca mulatta).

    Science.gov (United States)

    Valero, M D; Burton, J A; Hauser, S N; Hackett, T A; Ramachandran, R; Liberman, M C

    2017-09-01

    Cochlear synaptopathy can result from various insults, including acoustic trauma, aging, ototoxicity, or chronic conductive hearing loss. For example, moderate noise exposure in mice can destroy up to ∼50% of synapses between auditory nerve fibers (ANFs) and inner hair cells (IHCs) without affecting outer hair cells (OHCs) or thresholds, because the synaptopathy occurs first in high-threshold ANFs. However, the fiber loss likely impairs temporal processing and hearing-in-noise, a classic complaint of those with sensorineural hearing loss. Non-human primates appear to be less vulnerable to noise-induced hair-cell loss than rodents, but their susceptibility to synaptopathy has not been studied. Because establishing a non-human primate model may be important in the development of diagnostics and therapeutics, we examined cochlear innervation and the damaging effects of acoustic overexposure in young adult rhesus macaques. Anesthetized animals were exposed bilaterally to narrow-band noise centered at 2 kHz at various sound-pressure levels for 4 h. Cochlear function was assayed for up to 8 weeks following exposure via auditory brainstem responses (ABRs) and otoacoustic emissions (OAEs). A moderate loss of synaptic connections (mean of 12-27% in the basal half of the cochlea) followed temporary threshold shifts (TTS), despite minimal hair-cell loss. A dramatic loss of synapses (mean of 50-75% in the basal half of the cochlea) was seen on IHCs surviving noise exposures that produced permanent threshold shifts (PTS) and widespread hair-cell loss. Higher noise levels were required to produce PTS in macaques compared to rodents, suggesting that primates are less vulnerable to hair-cell loss. However, the phenomenon of noise-induced cochlear synaptopathy in primates is similar to that seen in rodents. Copyright © 2017 Elsevier B.V. All rights reserved.

  20. Spatial channel interactions in cochlear implants

    Science.gov (United States)

    Tang, Qing; Benítez, Raul; Zeng, Fan-Gang

    2011-08-01

    The modern multi-channel cochlear implant is widely considered to be the most successful neural prosthesis owing to its ability to restore partial hearing to post-lingually deafened adults and to allow essentially normal language development in pre-lingually deafened children. However, the implant performance varies greatly in individuals and is still limited in background noise, tonal language understanding, and music perception. One main cause for the individual variability and the limited performance in cochlear implants is spatial channel interaction from the stimulating electrodes to the auditory nerve and brain. Here we systematically examined spatial channel interactions at the physical, physiological, and perceptual levels in the same five modern cochlear implant subjects. The physical interaction was examined using an electric field imaging technique, which measured the voltage distribution as a function of the electrode position in the cochlea in response to the stimulation of a single electrode. The physiological interaction was examined by recording electrically evoked compound action potentials as a function of the electrode position in response to the stimulation of the same single electrode position. The perceptual interactions were characterized by changes in detection threshold as well as loudness summation in response to in-phase or out-of-phase dual-electrode stimulation. To minimize potentially confounding effects of temporal factors on spatial channel interactions, stimulus rates were limited to 100 Hz or less in all measurements. Several quantitative channel interaction indexes were developed to define and compare the width, slope and symmetry of the spatial excitation patterns derived from these physical, physiological and perceptual measures. The electric field imaging data revealed a broad but uniformly asymmetrical intracochlear electric field pattern, with the apical side producing a wider half-width and shallower slope than the basal

  1. Immediate and delayed cochlear neuropathy after noise exposure in pubescent mice

    DEFF Research Database (Denmark)

    Jensen, Jane Bjerg; Lysaght, Andrew C; Liberman, M Charles

    2015-01-01

    Moderate acoustic overexposure in adult rodents is known to cause acute loss of synapses on sensory inner hair cells (IHCs) and delayed degeneration of the auditory nerve, despite the completely reversible temporary threshold shift (TTS) and morphologically intact hair cells. Our objective...... to 16 months post exposure. Mice exposed to neuropathic noise demonstrated immediate cochlear synaptopathy by 24 hours post exposure, and delayed neurodegeneration characterized by axonal retraction at 8 months, and spiral ganglion cell loss at 8-16 months post exposure. Although the damage...

  2. Design of a new electrode array for cochlear implants

    International Nuclear Information System (INIS)

    Kha, H.; Chen, B.

    2010-01-01

    Full text: This study aims to design a new electrode array which can be precisely located beneath the basilar membrane within the cochlear scala tympani. This placement of the electrode array is beneficial for increasing the effectiveness of the electrical stimulation of the audi tory nerves and maximising the growth factors delivered into the cochlea for regenerating the progressively lost auditory neurons, thereby significantly improving performance of the cochlear implant systems. Methods The design process involved two steps. First, the biocom patible nitinol-based shape memory alloy, of which mechanical deformation can be controlled using electrical cUTents/fields act vated by body temperature, was selected. Second, five different designs of the electrode array with embedded nitinol actuators were studied (Table I). The finite element method was employed to predict final positions of these electrode arrays. Results The electrode array with three 6 mm actuators at 2-8, 8-J4 and 14-20 mm from the tip (Fig. I) was found to be located most closely to the basilar membrane, compared with those in the other four cases. Conclusions A new nitinol cochlear implant electrode array with three embedded nitinol actuators has been designed. This electrode array is expected to be located beneath the basilar membrane for maximising the delivery of growth factors. Future research will involve the manufacturing of a prototype of this electrode array for use in insertion experiments and neurotrophin release tests.

  3. Ototoxicity of paclitaxel in rat cochlear organotypic cultures

    International Nuclear Information System (INIS)

    Dong, Yang; Ding, Dalian; Jiang, Haiyan; Shi, Jian-rong; Salvi, Richard; Roth, Jerome A.

    2014-01-01

    Paclitaxel (taxol) is a widely used antineoplastic drug employed alone or in combination to treat many forms of cancer. Paclitaxel blocks microtubule depolymerization thereby stabilizing microtubules and suppressing cell proliferation and other cellular processes. Previous reports indicate that paclitaxel can cause mild to moderate sensorineural hearing loss and some histopathologic changes in the mouse cochlea; however, damage to the neurons and the underlying cell death mechanisms are poorly understood. To evaluate the ototoxicity of paclitaxel in more detail, cochlear organotypic cultures from postnatal day 3 rats were treated with paclitaxel for 24 or 48 h with doses ranging from 1 to 30 μM. No obvious histopathologies were observed after 24 h treatment with any of the paclitaxel doses employed, but with 48 h treatment, paclitaxel damaged cochlear hair cells in a dose-dependent manner and also damaged auditory nerve fibers and spiral ganglion neurons (SGN) near the base of the cochlea. TUNEL labeling was negative in the organ of Corti, but positive in SGN with karyorrhexis 48 h after 30 μM paclitaxel treatment. In addition, caspase-6, caspase-8 and caspase-9 labeling was present in SGN treated with 30 μM paclitaxel for 48 h. These results suggest that caspase-dependent apoptotic pathways are involved in paclitaxel-induced damage of SGN, but not hair cells in cochlea. - Highlights: • Paclitaxel was toxic to cochlear hair cells and spiral ganglion neurons. • Paclitaxel-induced spiral ganglion degeneration was apoptotic. • Paclitaxel activated caspase-6, -8 and -8 in spiral ganglion neurons

  4. "COCHLEAR IMPLANTATION IN PATIENTS WITH INNER EAR MALFORMATIONS"

    Directory of Open Access Journals (Sweden)

    P. Borghei S. Abdi

    2004-08-01

    Full Text Available Performing cochlear implantation in patients with inner ear malformation has always been a matter of dispute. This study was designed to analyze the operative findings,complications, and postoperative performance of patients with inner ear anomalies who underwent cochlear implantation. Six patients with inner ear malformations underwent implantation in our academic tertiary referral center from 1997 to 2002. The average follow-up period was 27 months. Malformations included one incomplete partition, one common cavity, one narrow internal acoustic canal (IAC in a patient with Riley-Day syndrome and 3 cases of large vestibular aqueduct. All received multi-channel implants either Nucleus 22 or Clarion device. Facial nerve was anomalous in 2 cases. CSF gusher occurred in 4 patients, which was controlled with packing the cochleostomy site. In all cases, the full length of electrode array was inserted, except one with Mondini's dysplasia where insertion failed in the first operation and was referred to another center for a successful surgery on the opposite ear. No other surgical complications were encountered. In 4 cases, all the 22 electrodes could be activated. All patients showed improved hearing performance after implantation. Four showed open-set speech recognition. The one with narrow IAC showed improved awareness to environmental sounds. In the other case (common cavity, the perception tests could not be performed because of very young age. Cochlear implantation in patients with inner ear malformations is a successful way of rehabilitation, although complications should be expected and auditory responses may be highly variable and relatively moderate.

  5. Ototoxicity of paclitaxel in rat cochlear organotypic cultures

    Energy Technology Data Exchange (ETDEWEB)

    Dong, Yang [Shanghai University of Traditional Chinese Medicine, Shanghai 201203 (China); Center for Hearing and Deafness, University at Buffalo, NY 14214 (United States); Ding, Dalian; Jiang, Haiyan [Center for Hearing and Deafness, University at Buffalo, NY 14214 (United States); Shi, Jian-rong [Shanghai University of Traditional Chinese Medicine, Shanghai 201203 (China); Salvi, Richard [Center for Hearing and Deafness, University at Buffalo, NY 14214 (United States); Roth, Jerome A., E-mail: jaroth@buffalo.edu [Department of Pharmacology and Toxicology, University at Buffalo, NY 14214 (United States)

    2014-11-01

    Paclitaxel (taxol) is a widely used antineoplastic drug employed alone or in combination to treat many forms of cancer. Paclitaxel blocks microtubule depolymerization thereby stabilizing microtubules and suppressing cell proliferation and other cellular processes. Previous reports indicate that paclitaxel can cause mild to moderate sensorineural hearing loss and some histopathologic changes in the mouse cochlea; however, damage to the neurons and the underlying cell death mechanisms are poorly understood. To evaluate the ototoxicity of paclitaxel in more detail, cochlear organotypic cultures from postnatal day 3 rats were treated with paclitaxel for 24 or 48 h with doses ranging from 1 to 30 μM. No obvious histopathologies were observed after 24 h treatment with any of the paclitaxel doses employed, but with 48 h treatment, paclitaxel damaged cochlear hair cells in a dose-dependent manner and also damaged auditory nerve fibers and spiral ganglion neurons (SGN) near the base of the cochlea. TUNEL labeling was negative in the organ of Corti, but positive in SGN with karyorrhexis 48 h after 30 μM paclitaxel treatment. In addition, caspase-6, caspase-8 and caspase-9 labeling was present in SGN treated with 30 μM paclitaxel for 48 h. These results suggest that caspase-dependent apoptotic pathways are involved in paclitaxel-induced damage of SGN, but not hair cells in cochlea. - Highlights: • Paclitaxel was toxic to cochlear hair cells and spiral ganglion neurons. • Paclitaxel-induced spiral ganglion degeneration was apoptotic. • Paclitaxel activated caspase-6, -8 and -8 in spiral ganglion neurons.

  6. Analysis of Changes in Auditory Nerve Signals Following Simulated Tinnitus for the Verification of Cochlear Model

    National Research Council Canada - National Science Library

    Yi, Y

    2001-01-01

    For an interpretation of the tinnitus phenomenon, reticular lamina which transmits energy in a cochlear was assumed as a mass and the components for the stiffness and control were added to the model...

  7. Electromyographic monitoring for prevention of phrenic nerve palsy in second-generation cryoballoon procedures.

    Science.gov (United States)

    Franceschi, Frédéric; Koutbi, Linda; Gitenay, Edouard; Hourdain, Jérome; Maille, Baptiste; Trévisan, Lory; Deharo, Jean-Claude

    2015-04-01

    Electromyography-guided phrenic nerve (PN) monitoring using a catheter positioned in a hepatic vein can aid in preventing phrenic nerve palsy (PNP) during cryoballoon ablation for atrial fibrillation. We wanted to evaluate the feasibility and efficacy of PN monitoring during procedures using second-generation cryoballoons. This study included 140 patients (43 women) in whom pulmonary vein isolation was performed using a second-generation cryoballoon. Electromyography-guided PN monitoring was performed by pacing the right PN at 60 per minute and recording diaphragmatic compound motor action potential (CMAP) via a quadripolar catheter positioned in a hepatic vein. If a 30% decrease in CMAP amplitude was observed, cryoapplication was discontinued with forced deflation to avoid a PNP. Monitoring was unfeasible in 8 of 140 patients (5.7%), PNP occurred in 1. Stable CMAP amplitudes were achieved before ablation in 132 of 140 patients (94.3%). In 18 of 132 patients (13.6%), a 30% decrease in CMAP amplitude occurred and cryoablation was discontinued. Each time, recovery of CMAP amplitude took <60 s. In 9 of 18 cases, a second cryoapplication in the same pulmonary vein was safely performed. We observed no PNP or complication related to electromyography-guided PN monitoring. Electromyography-guided PN monitoring using a catheter positioned in a hepatic vein seems feasible and effective to prevent PNP during cryoballoon ablation using second-generation cryoballoon. © 2015 American Heart Association, Inc.

  8. A surgical approach appropriate for targeted cochlear gene therapy in the mouse.

    Science.gov (United States)

    Jero, J; Tseng, C J; Mhatre, A N; Lalwani, A K

    2001-01-01

    Therapeutic manipulations of the mammalian cochlea, including cochlear gene transfer, have been predominantly studied using the guinea pig as the experimental model. With the significant developments in mouse genomics and the availability of mutant strains of mice with well-characterized hearing loss, the mouse justifiably will be the preferred animal model for therapeutic manipulations. However, the potential advantages of the mouse model have not been fully realized due to the surgical difficulty of accessing its small cochlea. This study describes a ventral approach, instead of the routinely used postauricular approach in other rodents, for accessing the mouse middle and inner ear, and its application in cochlear gene transfer. This ventral approach enabled rapid and direct delivery of liposome-transgene complex to the mouse inner ear while avoiding blood loss, facial nerve morbidity, and mortality. Transgene expression at 3 days was detected in Reissner's membrane, spiral limbus, spiral ligament, and spiral ganglion cells, in a pattern similar to that previously described in the guinea pig. The successful access and delivery of material to the mouse cochlea and the replication of gene expression seen in the guinea pig demonstrated in this study should promote the use of the mouse in future studies investigating targeted cochlear therapy.

  9. Benefits and Risks of Cochlear Implants

    Science.gov (United States)

    ... and Medical Procedures Implants and Prosthetics Cochlear Implants Benefits and Risks of Cochlear Implants Share Tweet Linkedin ... the Use of Cochlear Implants What are the Benefits of Cochlear Implants? For people with implants: Hearing ...

  10. Effect of age at cochlear implantation on auditory and speech development of children with auditory neuropathy spectrum disorder.

    Science.gov (United States)

    Liu, Yuying; Dong, Ruijuan; Li, Yuling; Xu, Tianqiu; Li, Yongxin; Chen, Xueqing; Gong, Shusheng

    2014-12-01

    To evaluate the auditory and speech abilities in children with auditory neuropathy spectrum disorder (ANSD) after cochlear implantation (CI) and determine the role of age at implantation. Ten children participated in this retrospective case series study. All children had evidence of ANSD. All subjects had no cochlear nerve deficiency on magnetic resonance imaging and had used the cochlear implants for a period of 12-84 months. We divided our children into two groups: children who underwent implantation before 24 months of age and children who underwent implantation after 24 months of age. Their auditory and speech abilities were evaluated using the following: behavioral audiometry, the Categories of Auditory Performance (CAP), the Meaningful Auditory Integration Scale (MAIS), the Infant-Toddler Meaningful Auditory Integration Scale (IT-MAIS), the Standard-Chinese version of the Monosyllabic Lexical Neighborhood Test (LNT), the Multisyllabic Lexical Neighborhood Test (MLNT), the Speech Intelligibility Rating (SIR) and the Meaningful Use of Speech Scale (MUSS). All children showed progress in their auditory and language abilities. The 4-frequency average hearing level (HL) (500Hz, 1000Hz, 2000Hz and 4000Hz) of aided hearing thresholds ranged from 17.5 to 57.5dB HL. All children developed time-related auditory perception and speech skills. Scores of children with ANSD who received cochlear implants before 24 months tended to be better than those of children who received cochlear implants after 24 months. Seven children completed the Mandarin Lexical Neighborhood Test. Approximately half of the children showed improved open-set speech recognition. Cochlear implantation is helpful for children with ANSD and may be a good optional treatment for many ANSD children. In addition, children with ANSD fitted with cochlear implants before 24 months tended to acquire auditory and speech skills better than children fitted with cochlear implants after 24 months. Copyright © 2014

  11. Assessment of Cochlear Function during Cochlear Implantation by Extra- and Intracochlear Electrocochleography

    OpenAIRE

    Dalbert, Adrian; Pfiffner, Flurin; Hoesli, Marco; Koka, Kanthaiah; Veraguth, Dorothe; Roosli, Christof; Huber, Alexander

    2018-01-01

    Objective: The aims of this study were: (1) To investigate the correlation between electrophysiological changes during cochlear implantation and postoperative hearing loss, and (2) to detect the time points that electrophysiological changes occur during cochlear implantation. Material and Methods: Extra- and intracochlear electrocochleography (ECoG) were used to detect electrophysiological changes during cochlear implantation. Extracochlear ECoG recordings were conducted through a needle elec...

  12. Value of free-run electromyographic monitoring of lower cranial nerves in endoscopic endonasal approach to skull base surgeries.

    Science.gov (United States)

    Thirumala, Parthasarathy D; Mohanraj, Santhosh Kumar; Habeych, Miguel; Wichman, Kelley; Chang, Yue-Fang; Gardner, Paul; Snyderman, Carl; Crammond, Donald J; Balzer, Jeffrey

    2012-08-01

    Objective The main objective of this study was to evaluate the value of free-run electromyography (f-EMG) monitoring of cranial nerves (CNs) VII, IX, X, XI, and XII in skull base surgeries performed using endoscopic endonasal approach (EEA) to reduce iatrogenic CN deficits. Design We retrospectively identified 73 patients out of 990 patients who had EEA in our institution who had at least one CN monitored. In each CN group, we classified patients who had significant (SG) f-EMG activity as group I and those who did not as group II. Results We monitored a total of 342 CNs. A total of 62 nerves had SG f-EMG activity including CN VII = 18, CN IX = 16, CN X = 13, CN XI = 5, and CN XII = 10. No nerve deficit was found in the nerves that had significant activity during procedure. A total of five nerve deficits including (CN IX = 1, CN X = 2, CN XII = 2) were observed in the group that did not display SG f-EMG activity during surgery. Conclusions f-EMG seems highly sensitive to surgical manipulations and in locating CNs. It seems to have limited value in predicting postoperative neurological deficits. Future studies to evaluate the EMG of lower CNs during EEA procedures need to be done with both f-EMG and triggered EMG.

  13. Trends in cochlear implants.

    Science.gov (United States)

    Zeng, Fan-Gang

    2004-01-01

    More than 60,000 people worldwide use cochlear implants as a means to restore functional hearing. Although individual performance variability is still high, an average implant user can talk on the phone in a quiet environment. Cochlear-implant research has also matured as a field, as evidenced by the exponential growth in both the patient population and scientific publication. The present report examines current issues related to audiologic, clinical, engineering, anatomic, and physiologic aspects of cochlear implants, focusing on their psychophysical, speech, music, and cognitive performance. This report also forecasts clinical and research trends related to presurgical evaluation, fitting protocols, signal processing, and postsurgical rehabilitation in cochlear implants. Finally, a future landscape in amplification is presented that requires a unique, yet complementary, contribution from hearing aids, middle ear implants, and cochlear implants to achieve a total solution to the entire spectrum of hearing loss treatment and management.

  14. Communication between cochlear perilymph and cerebrospinal fluid through the cochlear modiolus visualized after intratympanic administration of Gd-DTPA

    International Nuclear Information System (INIS)

    Naganawa, Shinji; Satake, Hiroko; Iwano, Shingo; Sone, Michihiko; Nakashima, Tsutomu

    2008-01-01

    Intratympanic injection of gadolinium diethylenetriaminepentaacetic acid (Gd-DTPA) has been reported as a procedure to visualize endolymphatic hydrops of Meniere's disease. We frequently noted that cerebrospinal fluid (CSF) in the internal auditory canal (IAC) was also enhanced after this procedure. The purpose of this study was to evaluate how frequently this occurs and to investigate the specific features of patients who lack this communication. A total of 25 patients with clinically suspected endolymphatic hydrops underwent the procedure. After 24 h, three-dimensional fluid-attenuated inversion recovery (3D-FLAIR) and 3D constructive interference in steady state (3D-CISS) were performed. The presence of contrast enhancement in the CSF space of the fundus of the IAC was evaluated. The contrast ratio between CSF of the IAC fundus and cerebellar white matter on the injected side was 1.49±0.65, and that of the noninjected side was 0.32±0.16 (P<0.01). Enhancement of the CSF space in the IAC fundus was seen in all but two subjects: one had enlarged endolymphatic duct and sac syndrome (EEDS), and the other had cochlear nerve agenesis. In these two patients, the cochlear modiolus seemed to be normal. Intratympanic Gd-DTPA administration can reveal permeability of the modiolus and might facilitate evaluation of functional abnormalities of the modiolus not detected by conventional imaging tests. (author)

  15. Congenitally Deafblind Children and Cochlear Implants

    DEFF Research Database (Denmark)

    Dammeyer, Jesper Herup

    2008-01-01

    There has been much research conducted demonstrating the positive benefits of cochlear implantation (CI) in children who are deaf. Research on cochlear implantation in children who are both deaf and blind, however, is lacking. The purpose of this article is to present a study of 5 congenitally...... deafblind children who received cochlear implants between 2.2 and 4.2 years of age.  Ratings of video observations were used to measure the children's early communication development with and without the use of their cochlear implants. In addition, parental interviews were used to assess the benefits...... parents perceived regarding their children's cochlear implants. Two examples are included in this article to illustrate the parents' perspectives about cochlear implantation in their deafblind children. Benefits of cochlear implantation in this cohort of children included improved attention and emotional...

  16. Auditory-nerve single-neuron thresholds to electrical stimulation from scala tympani electrodes.

    Science.gov (United States)

    Parkins, C W; Colombo, J

    1987-12-31

    Single auditory-nerve neuron thresholds were studied in sensory-deafened squirrel monkeys to determine the effects of electrical stimulus shape and frequency on single-neuron thresholds. Frequency was separated into its components, pulse width and pulse rate, which were analyzed separately. Square and sinusoidal pulse shapes were compared. There were no or questionably significant threshold differences in charge per phase between sinusoidal and square pulses of the same pulse width. There was a small (less than 0.5 dB) but significant threshold advantage for 200 microseconds/phase pulses delivered at low pulse rates (156 pps) compared to higher pulse rates (625 pps and 2500 pps). Pulse width was demonstrated to be the prime determinant of single-neuron threshold, resulting in strength-duration curves similar to other mammalian myelinated neurons, but with longer chronaxies. The most efficient electrical stimulus pulse width to use for cochlear implant stimulation was determined to be 100 microseconds/phase. This pulse width delivers the lowest charge/phase at threshold. The single-neuron strength-duration curves were compared to strength-duration curves of a computer model based on the specific anatomy of auditory-nerve neurons. The membrane capacitance and resulting chronaxie of the model can be varied by altering the length of the unmyelinated termination of the neuron, representing the unmyelinated portion of the neuron between the habenula perforata and the hair cell. This unmyelinated segment of the auditory-nerve neuron may be subject to aminoglycoside damage. Simulating a 10 micron unmyelinated termination for this model neuron produces a strength-duration curve that closely fits the single-neuron data obtained from aminoglycoside deafened animals. Both the model and the single-neuron strength-duration curves differ significantly from behavioral threshold data obtained from monkeys and humans with cochlear implants. This discrepancy can best be explained by

  17. Characterization of Cochlear, Vestibular and Cochlear-Vestibular Electrically Evoked Compound Action Potentials in Patients with a Vestibulo-Cochlear Implant

    Directory of Open Access Journals (Sweden)

    T. A. K. Nguyen

    2017-11-01

    Full Text Available The peripheral vestibular system is critical for the execution of activities of daily life as it provides movement and orientation information to motor and sensory systems. Patients with bilateral vestibular hypofunction experience a significant decrease in quality of life and have currently no viable treatment option. Vestibular implants could eventually restore vestibular function. Most vestibular implant prototypes to date are modified cochlear implants to fast-track development. These use various objective measurements, such as the electrically evoked compound action potential (eCAP, to supplement behavioral information. We investigated whether eCAPs could be recorded in patients with a vestibulo-cochlear implant. Specifically, eCAPs were successfully recorded for cochlear and vestibular setups, as well as for mixed cochlear-vestibular setups. Similarities and slight differences were found for the recordings of the three setups. These findings demonstrated the feasibility of eCAP recording with a vestibulo-cochlear implant. They could be used in the short term to reduce current spread and avoid activation of non-targeted neurons. More research is warranted to better understand the neural origin of vestibular eCAPs and to utilize them for clinical applications.

  18. Cochlear implantation in Mondini dysplasia.

    Science.gov (United States)

    Daneshi, Ahmad; Hassanzadeh, Saeid; Abasalipour, Parvaneh; Emamdjomeh, Hessamaddin; Farhadi, Mohammad

    2003-01-01

    The use of cochlear implantation to treat patients with inner ear malformations such as Mondini dysplasia has been increasingly successful. Until now, conventional hearing aids in these patients have not performed well. Consequently, the hearing problem for patients with this condition has been somewhat improved with the use of cochlear implants. Various results of cochlear implantation have been reported in these patients so far. This is a report of 5 patients with Mondini malformation who have undergone cochlear implant surgery. Copyright 2003 S. Karger AG, Basel

  19. Challenging aspects of contemporary cochlear implant electrode array design.

    Science.gov (United States)

    Mistrík, Pavel; Jolly, Claude; Sieber, Daniel; Hochmair, Ingeborg

    2017-12-01

    A design comparison of current perimodiolar and lateral wall electrode arrays of the cochlear implant (CI) is provided. The focus is on functional features such as acoustic frequency coverage and tonotopic mapping, battery consumption and dynamic range. A traumacity of their insertion is also evaluated. Review of up-to-date literature. Perimodiolar electrode arrays are positioned in the basal turn of the cochlea near the modiolus. They are designed to initiate the action potential in the proximity to the neural soma located in spiral ganglion. On the other hand, lateral wall electrode arrays can be inserted deeper inside the cochlea, as they are located along the lateral wall and such insertion trajectory is less traumatic. This class of arrays targets primarily surviving neural peripheral processes. Due to their larger insertion depth, lateral wall arrays can deliver lower acoustic frequencies in manner better corresponding to cochlear tonotopicity. In fact, spiral ganglion sections containing auditory nerve fibres tuned to low acoustic frequencies are located deeper than 1 and half turn inside the cochlea. For this reason, a significant frequency mismatch might be occurring for apical electrodes in perimodiolar arrays, detrimental to speech perception. Tonal languages such as Mandarin might be therefore better treated with lateral wall arrays. On the other hand, closer proximity to target tissue results in lower psychophysical threshold levels for perimodiolar arrays. However, the maximal comfort level is also lower, paradoxically resulting in narrower dynamic range than that of lateral wall arrays. Battery consumption is comparable for both types of arrays. Lateral wall arrays are less likely to cause trauma to cochlear structures. As the current trend in cochlear implantation is the maximal protection of residual acoustic hearing, the lateral wall arrays seem more suitable for hearing preservation CI surgeries. Future development could focus on combining the

  20. Cochlear vertebral entrapment syndrome: a case report

    Energy Technology Data Exchange (ETDEWEB)

    Liu Chinghsiung; Lin Shinnkuang E-mail: sk1943@adm.cgmh.org.tw; Chang Yeujhy

    2001-11-01

    The authors describe a patient with isolated involvement of vestibulocochlear nerve by a huge vascular loop from vertebral dolichoectasia. No other neurological deficit was found except for unilateral hearing loss. Abnormal brainstem auditory evoked potential study indicated a retrocochlear lesion. The brain computed tomography (CT) and magnetic resonance imaging (MRI) studies demonstrated an abnormally enhanced vascular lesion impinged on the left porus acusticus with a displacement of the brainstem to the right. There was no infarction in the brainstem. A cerebral angiography demonstrated a megadolichoectatic horizontal loop at the intracranial portion of the left vertebral artery. There was no thrombus or atherosclerosis in the vertebrobasilar system. A mechanical compression by a vascular loop is the only possible pathogenesis for hearing loss. The authors diagnose this condition as cochlear vertebral entrapment syndrome.

  1. [Morphologic feature and cochlear implant surgical approach for cochlear modiolus deficiency].

    Science.gov (United States)

    Zhang, Daoxing

    2014-09-01

    To review the classification of cochlear modiolus deficiency and decision on surgical approach for above case,in order to provide mastery for cochlear implant (CI) indication. Basing on temporal bone HRCT pre-operation, CI subjects with modiolus deficiency were defined as following groups: (1) deficiency caused by cochlear dysplasia (Mondini malformation); (2) deficiency caused by dysplasia of cochlear and vestibule (Common cavity malformation); (3) deficiency caused by absence of internal acoustic meatus fundus (IP-III malformation). Three types of surgical approach were utilized: type I, electrode array was introduced through facial recess, enlarged the round window, type II, opened the surface of chchlea, electrode array was introduced through facial recess, fenestration on posterior promontory and then inserted around lateral wall of inner-cochlear cavity. type III, electrode array was introduce through fenestration of lateral semicircular canal and then placed close to the bony wall of common cavity. One hundred and sixty-six cochlear modiolus deficiency cases were identified into 3 groups as following: 135 Mondini malformation cases into group a, 18 common cavity malformation cases into group b, and 13 IP-III malformation cases into group c. Surgical approach: type I were used in 136 cases (123 Mondini cases and 13 IP-III cases), while approach type II in 12 cases (12 Mondini cases), and approach type III in 18 cases (18 common cavity cases). Income post-operation of CI: For group a (Mondini malformation), post-activation mean hearing threshold in sound field was 65 dB, speech recognition score is 95% (single finals test) and 25% (signal initials test), while it was 80 dB, 60% and 0 for group b (Conmon cavity malformation), and it was 55 dB, 100% and 45% for group c (IP-III malformation). The income of speech recognition score for cochlear modiolus deficiency was relatively poor, group b was worst and group c was best, while group a moderate.

  2. COCHLEAR IMPLANTATION PREVALENCE IN ELDERLY

    Directory of Open Access Journals (Sweden)

    A. V. Starokha

    2014-01-01

    Full Text Available Current paper describes an experience of cochlear implantation in elderly. Cochlear implantation has become a widely accepted intervention in the treatment of individuals with severe-to-profound sensorineural hearing loss. Cochlear implants are now accepted as a standard of care to optimize hearing and subsequent speech development in children and adults with deafness. But cochlear implantation affects not only hearing abilities, speech perception and speech production; it also has an outstanding impact on the social life, activities and self-esteem of each patient. The aim of this study was to evaluate the cochlear implantation efficacy in elderly with severe to profound sensorineural hearing loss. There were 5 patients under our observation. Surgery was performed according to traditional posterior tympanotomy and cochleostomy for cochlear implant electrode insertion for all observed patients. The study was conducted in two stages: before speech processor’s activation and 3 months later. Pure tone free field audiometry was performed to each patient to assess the efficiency of cochlear implantation in dynamics. The aim of the study was also to evaluate quality of life in elderly with severe to profound sensorineural hearing loss after unilateral cochlear implantation. Each patient underwent questioning with 36 Item Short Form Health Survey (SF-36. SF-36 is a set of generic, coherent, and easily administered quality-of-life measures. The SF-36 consists of eight scaled scores, which are the weighted sums of the questions in their section. Each scale is directly transformed into a 0-100 scale on the assumption that each question carries equal weight. The eight sections are: physical functioning; physical role functioning; emotional role functioning; vitality; emotional well-being; social role functioning; bodily pain; general health perceptions. Our results demonstrate that cochlear implantation in elderly consistently improved quality of life

  3. Selective pelvic autonomic nerve stimulation with simultaneous intraoperative monitoring of internal anal sphincter and bladder innervation.

    Science.gov (United States)

    Kneist, W; Kauff, D W; Koch, K P; Schmidtmann, I; Heimann, A; Hoffmann, K P; Lang, H

    2011-01-01

    Pelvic autonomic nerve preservation avoids postoperative functional disturbances. The aim of this feasibility study was to develop a neuromonitoring system with simultaneous intraoperative verification of internal anal sphincter (IAS) activity and intravesical pressure. 14 pigs underwent low anterior rectal resection. During intermittent bipolar electric stimulation of the inferior hypogastric plexus (IHP) and the pelvic splanchnic nerves (PSN), electromyographic signals of the IAS and manometry of the urinary bladder were observed simultaneously. Stimulation of IHP and PSN as well as simultaneous intraoperative monitoring could be realized with an adapted neuromonitoring device. Neurostimulation resulted in either bladder or IAS activation or concerted activation of both. Intravesical pressure increase as well as amplitude increase of the IAS neuromonitoring signal did not differ significantly between stimulation of IHP and PSN [6.0 cm H(2)O (interquartile range [IQR] 3.5-9.0) vs. 6.0 cm H(2)O (IQR 3.0-10.0) and 12.1 μV (IQR 3.0-36.7) vs. 40.1 μV (IQR 9.0-64.3)] (p > 0.05). Pelvic autonomic nerve stimulation with simultaneous intraoperative monitoring of IAS and bladder innervation is feasible. The method may enable neuromonitoring with increasing selectivity for pelvic autonomic nerve preservation. Copyright © 2011 S. Karger AG, Basel.

  4. Role of motor-evoked potential monitoring in conjunction with temporary clipping of spinal nerve roots in posterior thoracic spine tumor surgery.

    Science.gov (United States)

    Eleraky, Mohammed A; Setzer, Matthias; Papanastassiou, Ioannis D; Baaj, Ali A; Tran, Nam D; Katsares, Kiesha M; Vrionis, Frank D

    2010-05-01

    The vascular supply of the thoracic spinal cord depends on the thoracolumbar segmental arteries. Because of the small size and ventral course of these arteries in relation to the dorsal root ganglion and ventral root, they cannot be reliably identified during surgery by anatomic or morphologic criteria. Sacrificing them will most likely result in paraplegia. The goal of this study was to evaluate a novel method of intraoperative testing of a nerve root's contribution to the blood supply of the thoracic spinal cord. This is a clinical retrospective study of 49 patients diagnosed with thoracic spine tumors. Temporary nerve root clipping combined with motor-evoked potential (MEP) and somatosensory-evoked potential (SSEP) monitoring was performed; additionally, postoperative clinical evaluation was done and reported in all cases. All cases were monitored by SSEP and MEPs. The nerve root to be sacrificed was temporarily clipped using standard aneurysm clips, and SSEP/MEP were assessed before and after clipping. Four nerve roots were sacrificed in four cases, three nerve roots in eight cases, and two nerve roots in 22 cases. Nerve roots were sacrificed bilaterally in 12 cases. Most patients (47/49) had no changes in MEP/SSEP and had no neurological deficit postoperatively. One case of a spinal sarcoma demonstrated changes in MEP after temporary clipping of the left T11 nerve root. The nerve was not sacrificed, and the patient was neurologically intact after surgery. In another case of a sarcoma, MEPs changed in the lower limbs after ligation of left T9 nerve root. It was felt that it was a global event because of anesthesia. Postoperatively, the patient had complete paraplegia but recovered almost completely after 6 months. Temporary nerve root clipping combined with MEP and SSEP monitoring may enhance the impact of neuromonitoring in the intraoperative management of patients with thoracic spine tumors and favorably influence neurological outcome. Copyright 2010 Elsevier

  5. Congenital malformations of the inner ear and the vestibulocochlear nerve in children with sensorineural hearing loss: evaluation with CT and MRI.

    Science.gov (United States)

    Westerhof, J P; Rademaker, J; Weber, B P; Becker, H

    2001-01-01

    The purpose of this work was to study the diagnostic value of CT and MRI in children with sensorineural hearing loss and to analyze anatomic abnormalities of the inner ear and the vestibulocochlear nerve in this patient group. We evaluated 42 inner ears in 21 children with congenital deafness who had congenital inner ear malformations and who were candidates for cochlear implants. All patients were studied with high resolution MR and helical CT examinations. The MR study included a T2-weighted 3D fast SE sequence. We describe and tabulate the anatomic abnormalities. Special attention was given to abnormalities of the vestibulocochlear nerve. The field of view in the plane according to the length axis of the internal auditory canal (IAC) was 4 cm. Additional continuous parasagittal reformations perpendicular to the length axis of the IAC were studied with a field of view of 3 cm. CT and MRI allowed accurate identification of malformations of the inner ear in children with congenital deafness. We identified 99 malformations, with a majority of patients demonstrating multiple abnormalities. Common imaging findings were Mondini abnormality and Mondini variants (12/42) and fusion of the lateral or superior semicircular canal with the vestibule (12/42). MRI demonstrated in 9 of 21 patients a rudimentary or absent vestibulocochlear nerve in the auditory canal. CT and MRI are important modalities to analyze the inner ear in children who are candidates for cochlear implants. MRI with an extremely small field of view should be used to study possible abnormalities of the vestibulocochlear nerves. This may alter clinical care and allow cochlear implant placement in patients whose electrodiagnostic studies suggest that the implant should not be performed. The detailed analysis of abnormalities of the inner ear might establish prognostic factors.

  6. Cochlear implants in Waardenburg syndrome.

    Science.gov (United States)

    Cullen, Robert D; Zdanski, Carlton; Roush, Patricia; Brown, Carolyn; Teagle, Holly; Pillsbury, Harold C; Buchman, Craig

    2006-07-01

    Waardenburg syndrome is an autosomal-dominant syndrome characterized by dystopia canthorum, hyperplasia of the eyebrows, heterochromia irides, a white forelock, and sensorineural hearing loss in 20% to 55% of patients. This patient population accounts for approximately 2% of congenitally deaf children. The purpose of this retrospective case review was to describe the outcomes for those children with Waardenburg syndrome who have undergone cochlear implantation. Pediatric cochlear implant recipients with documented evidence of Waardenburg syndrome underwent retrospective case review. All patients received their cochlear implants at the study institution followed by outpatient auditory habilitation. Charts were reviewed for etiology and duration of deafness, age at time of cochlear implantation, perioperative complications, duration of use, and performance outcomes. Results of standard tests batteries for speech perception and production administered as a part of the patients' auditory habilitation were reviewed. Seven patients with Waardenburg syndrome and cochlear implants were identified. The average age at implantation was 37 months (range, 18-64 months) and the average duration of use was 69 months (range, 12-143 months). All of these patients are active users of their devices and perform very well after implantation. There were no major complications in this small group of patients. Children with congenital sensorineural hearing loss without other comorbidities (e.g., developmental delay, inner ear malformations) perform well when they receive cochlear implantation and auditory habilitation. Patients with Waardenburg syndrome can be expected to have above-average performance after cochlear implantation.

  7. CT evaluation of preoperative cochlear implantation cochlear implantation

    International Nuclear Information System (INIS)

    Tan Xiuzhong; Zhong Lansheng; Lan Bowen; Huang Yaosheng; Du Baowen; Zhu Jian

    2004-01-01

    Objective: To evaluate CT scan as a preoperative evaluation for cochlear implantation candidates. Methods: Axial high-resolution temporal bone CT and three-dimensional reconstruction of inner ear were performed in 93 patients with sensorineural hearing loss. results: Among 81 patients with congenital sensorineural deafness, Mondini malformation was seen in 7 case (13 ears); large vestibular aqueduct syndrome (LVAS) was revealed in 5 cases (8 ears); and inner ear ossification was found in 1 case (2 ears). In 1 case (2 ears) of inner ear fibrosis, reduced cochlear signal was noted on MRI but no unremarkable findings was shown on CT scan, however, in the operation, the device could not inserted into the basal circle of the cochlea, due to fibrous obliteration. In 12 patients with post-speech deafness, chronic suppurative tympanitis was seen in 2 cases (4 ears), and inner ear ossification was revealed in 1 case (2 ears). Conclusion: CT plays an indispensable role in the pre-operative evaluation of cochlear implantation. T 2 -weighted FSE-MRI of the inner ear is a useful complementary to CT scan. (authors)

  8. Neuro-otological and peripheral nerve involvement in Fabry disease

    Directory of Open Access Journals (Sweden)

    Sergio Carmona

    2017-07-01

    Full Text Available Fabry disease (FD is an X-linked lysosomal storage disease, with multisystemic glycosphingolipids deposits. Neuro-otological involvement leading to hearing loss and vestibular dysfunctions has been described, but there is limited information about the frequency, site of lesion, or the relationship with peripheral neuropathy. The aim was to evaluate the presence of auditory and vestibular symptoms, and assess neurophysiological involvement of the VIII cranial nerve, correlating these findings with clinical and neurophysiological features of peripheral neuropathy. We studied 36 patients with FD with a complete neurological and neuro-otological evaluation including nerve conduction studies, quantitative sensory testing (to evaluate small fiber by warm and cold threshold detection and cold and heat pain, vestibular evoked myogenic potentials, videonistagmography, audiometry and brainstem auditory evoked potentials. Neuro-otologic symptoms included hearing loss (22.2%, vertigo (27.8% or both (25%. An involvement of either cochlear or vestibular function was identified in most patients (75%. In 70% of our patients the involvement of both cochlear and vestibular function could not be explained by a neural or vascular mechanism. Small fiber neuropathy was identified in 77.7%. There were no significant associations between neurootological and QST abnormalities. Neuro-otologic involvement is frequent and most likely under-recognized in patients with FD. It lacks a specific neural or vascular pattern, suggesting multi-systemic, end organ damage. Small fiber neuropathy is an earlier manifestation of FD, but there is no correlation between the development of neuropathy and neuro-otological abnormalities.

  9. Audiovisual segregation in cochlear implant users.

    Directory of Open Access Journals (Sweden)

    Simon Landry

    Full Text Available It has traditionally been assumed that cochlear implant users de facto perform atypically in audiovisual tasks. However, a recent study that combined an auditory task with visual distractors suggests that only those cochlear implant users that are not proficient at recognizing speech sounds might show abnormal audiovisual interactions. The present study aims at reinforcing this notion by investigating the audiovisual segregation abilities of cochlear implant users in a visual task with auditory distractors. Speechreading was assessed in two groups of cochlear implant users (proficient and non-proficient at sound recognition, as well as in normal controls. A visual speech recognition task (i.e. speechreading was administered either in silence or in combination with three types of auditory distractors: i noise ii reverse speech sound and iii non-altered speech sound. Cochlear implant users proficient at speech recognition performed like normal controls in all conditions, whereas non-proficient users showed significantly different audiovisual segregation patterns in both speech conditions. These results confirm that normal-like audiovisual segregation is possible in highly skilled cochlear implant users and, consequently, that proficient and non-proficient CI users cannot be lumped into a single group. This important feature must be taken into account in further studies of audiovisual interactions in cochlear implant users.

  10. Noise Stress Induces an Epidermal Growth Factor Receptor/Xeroderma Pigmentosum-A Response in the Auditory Nerve.

    Science.gov (United States)

    Guthrie, O'neil W

    2017-03-01

    In response to toxic stressors, cancer cells defend themselves by mobilizing one or more epidermal growth factor receptor (EGFR) cascades that employ xeroderma pigmentosum-A (XPA) to repair damaged genes. Recent experiments discovered that neurons within the auditory nerve exhibit basal levels of EGFR+XPA co-expression. This finding implied that auditory neurons in particular or neurons in general have the capacity to mobilize an EGFR+XPA defense. Therefore, the current study tested the hypothesis that noise stress would alter the expression pattern of EGFR/XPA within the auditory nerve. Design-based stereology was used to quantify the proportion of neurons that expressed EGFR, XPA, and EGFR+XPA with and without noise stress. The results revealed an intricate neuronal response that is suggestive of alterations to both co-expression and individual expression of EGFR and XPA. In both the apical and middle cochlear coils, the noise stress depleted EGFR+XPA expression. Furthermore, there was a reduction in the proportion of neurons that expressed XPA-alone in the middle coils. However, the noise stress caused a significant increase in the proportion of neurons that expressed EGFR-alone in the middle coils. The basal cochlear coils failed to mobilize a significant response to the noise stress. These results suggest that EGFR and XPA might be part of the molecular defense repertoire of the auditory nerve.

  11. Noise Stress Induces an Epidermal Growth Factor Receptor/Xeroderma Pigmentosum–A Response in the Auditory Nerve

    Science.gov (United States)

    Guthrie, O’neil W.

    2017-01-01

    In response to toxic stressors, cancer cells defend themselves by mobilizing one or more epidermal growth factor receptor (EGFR) cascades that employ xeroderma pigmentosum–A (XPA) to repair damaged genes. Recent experiments discovered that neurons within the auditory nerve exhibit basal levels of EGFR+XPA co-expression. This finding implied that auditory neurons in particular or neurons in general have the capacity to mobilize an EGFR+XPA defense. Therefore, the current study tested the hypothesis that noise stress would alter the expression pattern of EGFR/XPA within the auditory nerve. Design-based stereology was used to quantify the proportion of neurons that expressed EGFR, XPA, and EGFR+XPA with and without noise stress. The results revealed an intricate neuronal response that is suggestive of alterations to both co-expression and individual expression of EGFR and XPA. In both the apical and middle cochlear coils, the noise stress depleted EGFR+XPA expression. Furthermore, there was a reduction in the proportion of neurons that expressed XPA-alone in the middle coils. However, the noise stress caused a significant increase in the proportion of neurons that expressed EGFR-alone in the middle coils. The basal cochlear coils failed to mobilize a significant response to the noise stress. These results suggest that EGFR and XPA might be part of the molecular defense repertoire of the auditory nerve. PMID:28056182

  12. Value of Free-Run Electromyographic Monitoring of Extraocular Cranial Nerves during Expanded Endonasal Surgery (EES) of the Skull Base.

    Science.gov (United States)

    Thirumala, Parthasarathy D; Mohanraj, Santhosh Kumar; Habeych, Miguel; Wichman, Kelley; Chang, Yue-Fang; Gardner, Paul; Snyderman, Carl; Crammond, Donald J; Balzer, Jeffrey

    2013-06-01

    Objective To evaluate the value of free-run electromyography (f-EMG) monitoring of extraocular cranial nerves (EOCN) III, IV, and VI during expanded endonasal surgery (EES) of the skull base in reducing iatrogenic cranial nerve (CN) deficits. Design We retrospectively identified 200 patients out of 990 who had at least one EOCN monitored during EES. We further separated patients into groups according to the specific CN monitored. In each CN group, we classified patients who had significant (SG) f-EMG activity as Group I and those who did not as Group II. Results A total of 696 EOCNs were monitored. The number of muscles supplied by EOCNs that had SG f-EMG activity was 88, including CN III = 46, CN IV = 21, and CN VI = 21. There were two deficits involving CN VI in patients who had SG f-EMG activity during surgery. There were 14 deficits observed, including CN III = 3, CN IV = 2, and CN VI = 9 in patients who did not have SG f-EMG activity during surgery. Conclusions f-EMG monitoring of EOCN during EES can be useful in identifying the location of the nerve. It seems to have limited value in predicting postoperative neurological deficits. Future studies to evaluate the EMG of EOCN during EES need to be done with both f-EMG and triggered EMG.

  13. Cochlear implants and medical tourism.

    Science.gov (United States)

    McKinnon, Brian J; Bhatt, Nishant

    2010-09-01

    To compare the costs of medical tourism in cochlear implant surgery performed in India as compared to the United States. In addition, the cost savings of obtaining cochlear implant surgery in India were compare d to those of other surgical interventions obtained as a medical tourist. Searches were conducted on Medline and Google using the search terms: 'medical tourism', 'medical offshoring', 'medical outsourcing', 'cochlear implants' and 'cochlear implantation'. The information regarding cost of medical treatment was obtained from personal communication with individuals familiar with India's cochlear implantation medical tourism industry. The range of cost depended on length of stay as well as the device chosen. Generally the cost, inclusive of travel, surgery and device, was in the range of $21,000-30,000, as compared to a cost range of $40,000-$60,000 in the US. With the escalating cost of healthcare in the United States, it is not surprising that some patients would seek to obtain surgical care overseas at a fraction of the cost. Participants in medical tourism often have financial resources, but lack health insurance coverage. While cardiovascular and orthopedic surgery performed outside the United States in India at centers that cater to medical tourists are often performed at one-quarter to one-third of the cost that would have been paid in the United States, the cost differential for cochlear implants is not nearly as favorable.

  14. Site of cochlear stimulation and its effect on electrically evoked compound action potentials using the MED-EL standard electrode array

    Directory of Open Access Journals (Sweden)

    Helbig Silke

    2009-12-01

    Full Text Available Abstract Background The standard electrode array for the MED-EL MAESTRO cochlear implant system is 31 mm in length which allows an insertion angle of approximately 720°. When fully inserted, this long electrode array is capable of stimulating the most apical region of the cochlea. No investigation has explored Electrically Evoked Compound Action Potential (ECAP recordings in this region with a large number of subjects using a commercially available cochlear implant system. The aim of this study is to determine if certain properties of ECAP recordings vary, depending on the stimulation site in the cochlea. Methods Recordings of auditory nerve responses were conducted in 67 subjects to demonstrate the feasibility of ECAP recordings using the Auditory Nerve Response Telemetry (ART™ feature of the MED-EL MAESTRO system software. These recordings were then analyzed based on the site of cochlear stimulation defined as basal, middle and apical to determine if the amplitude, threshold and slope of the amplitude growth function and the refractory time differs depending on the region of stimulation. Results Findings show significant differences in the ECAP recordings depending on the stimulation site. Comparing the apical with the basal region, on average higher amplitudes, lower thresholds and steeper slopes of the amplitude growth function have been observed. The refractory time shows an overall dependence on cochlear region; however post-hoc tests showed no significant effect between individual regions. Conclusions Obtaining ECAP recordings is also possible in the most apical region of the cochlea. However, differences can be observed depending on the region of the cochlea stimulated. Specifically, significant higher ECAP amplitude, lower thresholds and steeper amplitude growth function slopes have been observed in the apical region. These differences could be explained by the location of the stimulating electrode with respect to the neural tissue

  15. Neurovascular compression syndrome of the eighth cranial nerve

    International Nuclear Information System (INIS)

    Itoh, Akinori

    2010-01-01

    Neurovascular compression syndrome (NVCS) involves neuropathy due to intracranial blood vessels compressing the cranial nerves. NVCS of the eighth cranial nerve is less reportedly established as a clinical entity than that of the fifth and seventh cranial nerves. We report 17 cases of NVCS of the eighth cranial nerve and their clinical features. Clinical symptoms and test findings among our subjects indicated that most were aged more than 65 years, were unilateral, had intermittent tinnitus, suffered attacks lasting a few seconds dozens of times a day, experienced dizziness concomitantly with tinnitus, aggravated tinnitus and dizziness when tilting the head toward the affected side and looking downward (positional tinnitus, positional dizziness), heard specific tinnitus sounds such as crackling differing from those in cochlear tinnitus, had mild or no hearing loss, were diagnosed with retrocochlear hearing disturbance due to an interpeak latency delay between waves I and III of the auditory brainstem response (ABR), often had no nystagmus or canal paresis (CP), were found in constructive interference steady state magnetic resonance imaging (CISS MRI) to have compression of the eighth cranial nerve by the vertebral artery (VA) or the anterior inferior cerebellar artery (AICA), rarely had concomitant facial spasms, and had tinnitus and dizziness markedly suppressed by carbamazepine. With the number of elderly individuals continuing to increase, cases of NVCS due to arteriosclerotic changes in cerebral blood vessels are expected to increase, making it necessary to consider NVCS in elderly subjects with dizziness, tinnitus, and hearing loss. (author)

  16. Neurovascular compression syndrome of the eighth cranial nerve

    Energy Technology Data Exchange (ETDEWEB)

    Itoh, Akinori [Saitama Medical Univ., Faculty of Medicine, Moroyama, Saitama (Japan)

    2010-04-15

    Neurovascular compression syndrome (NVCS) involves neuropathy due to intracranial blood vessels compressing the cranial nerves. NVCS of the eighth cranial nerve is less reportedly established as a clinical entity than that of the fifth and seventh cranial nerves. We report 17 cases of NVCS of the eighth cranial nerve and their clinical features. Clinical symptoms and test findings among our subjects indicated that most were aged more than 65 years, were unilateral, had intermittent tinnitus, suffered attacks lasting a few seconds dozens of times a day, experienced dizziness concomitantly with tinnitus, aggravated tinnitus and dizziness when tilting the head toward the affected side and looking downward (positional tinnitus, positional dizziness), heard specific tinnitus sounds such as crackling differing from those in cochlear tinnitus, had mild or no hearing loss, were diagnosed with retrocochlear hearing disturbance due to an interpeak latency delay between waves I and III of the auditory brainstem response (ABR), often had no nystagmus or canal paresis (CP), were found in constructive interference steady state magnetic resonance imaging (CISS MRI) to have compression of the eighth cranial nerve by the vertebral artery (VA) or the anterior inferior cerebellar artery (AICA), rarely had concomitant facial spasms, and had tinnitus and dizziness markedly suppressed by carbamazepine. With the number of elderly individuals continuing to increase, cases of NVCS due to arteriosclerotic changes in cerebral blood vessels are expected to increase, making it necessary to consider NVCS in elderly subjects with dizziness, tinnitus, and hearing loss. (author)

  17. Surgery for traumatic facial nerve paralysis: does intraoperative monitoring have a role?

    Science.gov (United States)

    Ashram, Yasmine A; Badr-El-Dine, Mohamed M K

    2014-09-01

    The use of intraoperative facial nerve (FN) monitoring during surgical decompression of the FN is underscored because surgery is indicated when the FN shows more than 90 % axonal degeneration. The present study proposes including intraoperative monitoring to facilitate decision taking and provide prognostication with more accuracy. This prospective study was conducted on ten patients presenting with complete FN paralysis due to temporal bone fracture. They were referred after variable time intervals for FN exploration and decompression. Intraoperative supramaximal electric stimulation (2-3 mA) of the FN was attempted in all patients both proximal and distal to the site of injury. Postoperative FN function was assessed using House-Brackmann (HB) scale. All patients had follow-up period ranging from 7 to 42 months. Three different patterns of neurophysiological responses were characterized. Responses were recorded proximal and distal to the lesion in five patients (pattern 1); only distal to the lesion in two patients (pattern 2); and neither proximal nor distal to the lesion in three patients (pattern 3). Sporadic, mechanically elicited EMG activity was recorded in eight out of ten patients. Patients with pattern 1 had favorable prognosis with postoperative function ranging between grade I and III. Pattern 3 patients showing no mechanically elicited activity had poor prognosis. Intraoperative monitoring affects decision taking during surgery for traumatic FN paralysis and provides prognostication with sufficient accuracy. The detection of mechanically elicited EMG activity is an additional sign predicting favorable outcome. However, absence of responses did not alter surgeon decision when the nerve was found evidently intact.

  18. Parental expectations and outcomes of pediatric cochlear implantation.

    Science.gov (United States)

    Piazza, Elizabeth; Kandathil, Cherian; Carron, Jeffrey D

    2009-10-01

    Cochlear implants have been used with increasing frequency over the past twenty years, including very young patients. To determine if parents are satisfied with their children's performance after cochlear implantation. Survey mailed to parents of children receiving cochlear implants. 31 questionnaires were returned out of 69 mailed (45 %). The vast majority of responding parents felt that their children benefited substantially from cochlear implant surgery. Cochlear implantation is effective in helping children develop auditory-oral communication skills. Access to auditory/oral communication programs in this state remains an obstacle in postoperative habilitation.

  19. Benefits and detriments of unilateral cochlear implant use on bilateral auditory development in children who are deaf

    Directory of Open Access Journals (Sweden)

    Karen A. Gordon

    2013-10-01

    Full Text Available We have explored both the benefits and detriments of providing electrical input through a cochlear implant in one ear to the auditory system of young children. A cochlear implant delivers electrical pulses to stimulate the auditory nerve, providing children who are deaf with access to sound. The goals of implantation are to restrict reorganization of the deprived immature auditory brain and promote development of hearing and spoken language. It is clear that limiting the duration of deprivation is a key factor. Additional considerations are the onset, etiology, and use of residual hearing as each of these can have unique effects on auditory development in the pre-implant period. New findings show that many children receiving unilateral cochlear implants are developing mature-like brainstem and thalamo-cortical responses to sound with long term use despite these sources of variability; however, there remain considerable abnormalities in cortical function. The most apparent, determined by implanting the other ear and measuring responses to acute stimulation, is a loss of normal cortical response from the deprived ear. Recent data reveal that this can be avoided in children by early implantation of both ears simultaneously or with limited delay. We conclude that auditory development requires input early in development and from both ears.

  20. A two-microphone noise reduction system for cochlear implant users with nearby microphones. Part I: Signal processing algorithm design and development

    OpenAIRE

    Kompis, Martin; Bertram, Matthias; François, Jacques; Pelizzone, Marco

    2008-01-01

    Users of cochlear implant systems, that is, of auditory aids which stimulate the auditory nerve at the cochlea electrically, often complain about poor speech understanding in noisy environments. Despite the proven advantages of multimicrophone directional noise reduction systems for conventional hearing aids, only one major manufacturer has so far implemented such a system in a product, presumably because of the added power consumption and size. We present a physically small (intermicrophone ...

  1. Intraoperative facial motor evoked potentials monitoring with transcranial electrical stimulation for preservation of facial nerve function in patients with large acoustic neuroma

    Institute of Scientific and Technical Information of China (English)

    LIU Bai-yun; TIAN Yong-ji; LIU Wen; LIU Shu-ling; QIAO Hui; ZHANG Jun-ting; JIA Gui-jun

    2007-01-01

    Background Although various monitoring techniques have been used routinely in the treatment of the lesions in the skull base, iatrogenic facial paresis or paralysis remains a significant clinical problem. The aim of this study was to investigate the effect of intraoperative facial motor evoked potentials monitoring with transcranial electrical stimulation on preservation of facial nerve function.Method From January to November 2005, 19 patients with large acoustic neuroma were treated using intraoperative facial motor evoked potentials monitoring with transcranial electrical stimulation (TCEMEP) for preservation of facial nerve function. The relationship between the decrease of MEP amplitude after tumor removal and the postoperative function of the facial nerve was analyzed.Results MEP amplitude decreased more than 75% in 11 patients, of which 6 presented significant facial paralysis (H-B grade 3), and 5 had mild facial paralysis (H-B grade 2). In the other 8 patients, whose MEP amplitude decreased less than 75%, 1 experienced significant facial paralysis, 5 had mild facial paralysis, and 2 were normal.Conclusions Intraoperative TCEMEP can be used to predict postoperative function of the facial nerve. The decreased MEP amplitude above 75 % is an alarm point for possible severe facial paralysis.

  2. Retrograde transport of [3H]-D-aspartate label by cochlear and vestibular efferent neurons

    International Nuclear Information System (INIS)

    Schwarz, D.W.; Schwarz, I.E.

    1988-01-01

    [ 3 H]-D-aspartic acid was injected into the inner ear of rats. After a six hour survival time, labeled cells were found at all locations known to contain efferent cochlear or vestibular neurons. Most labeled neurons were found in the ipsilateral lateral superior olivary nucleus (LSO), although both ventral nuclei of the trapezoid body (VTB), group E, and the caudal pontine reticular nucleus (CPR) just adjacent to the ascending limb of the facial nerve also contained labeled cells. Because not all efferent neurons in the rat could be previously shown to be cholinergic, aspartate and glutamate are efferent transmitter candidates

  3. A Two-Microphone Noise Reduction System for Cochlear Implant Users with Nearby Microphones—Part II: Performance Evaluation

    Directory of Open Access Journals (Sweden)

    Rudolf Häusler

    2008-06-01

    Full Text Available Users of cochlear implants (auditory aids, which stimulate the auditory nerve electrically at the inner ear often suffer from poor speech understanding in noise. We evaluate a small (intermicrophone distance 7 mm and computationally inexpensive adaptive noise reduction system suitable for behind-the-ear cochlear implant speech processors. The system is evaluated in simulated and real, anechoic and reverberant environments. Results from simulations show improvements of 3.4 to 9.3 dB in signal to noise ratio for rooms with realistic reverberation and more than 18 dB under anechoic conditions. Speech understanding in noise is measured in 6 adult cochlear implant users in a reverberant room, showing average improvements of 7.9–9.6 dB, when compared to a single omnidirectional microphone or 1.3–5.6 dB, when compared to a simple directional two-microphone device. Subjective evaluation in a cafeteria at lunchtime shows a preference of the cochlear implant users for the evaluated device in terms of speech understanding and sound quality.

  4. Quantitative relations between the eyeball, the optic nerve, and the optic canal important for intracranial pressure monitoring.

    Science.gov (United States)

    Vaiman, Michael; Gottlieb, Paul; Bekerman, Inessa

    2014-08-17

    To find correlations between diameters of the optic nerve sheath (ONSD), the eyeball, and the optic canal that might be important for intracranial pressure monitoring. In a prospective cohort study, the CT data of consecutive 400 adults (18+) with healthy eyes and optic nerves and absence of neurological diseases were collected and analyzed. When the CT scans were obtained, the diameters of the optic nerve sheath, the eyeball, and the optic canal were measured and statistically analyzed. The data obtained from the left and from the right eyeballs and optic nerves were compared. The correlation analysis was performed within these variables, with the gender, and the age. In healthy persons, the ONSD varies from 3.65 mm to 5.17 mm in different locations within the intraorbital space with no significant difference between sexes and age groups. There is a strong correlation between the eyeball transverse diameter (ETD) and ONSD that can be presented as ONSD/ETD index. In healthy subjects, the ONSD/ETD index equals 0.19. The calculation of an index when ONSD is divided by the ETD of the eyeball presents precise normative database for ONSD intracranial pressure measurement technique. When the ONSD is measured for intracranial pressure monitoring, the most stable results can be obtained if the diameter is measured 10 mm from the globe. These data might serve as a normative database at emergency departments and in general neurological practice.

  5. [Multi-channel cochlear implants in patients with Mondini malformation].

    Science.gov (United States)

    Li, Yong-xin; Han, De-min; Zhao, Xiao-tian; Chen, Xue-qing; Kong, Ying; Zheng, Jun; Liu, Bo; Liu, Sha; Mo, Ling-yan; Zhang, Hua; Wang, Shuo

    2004-02-01

    To describe clinical experiences with multi-channel cochlear implantation in patients with Mondini malformation. Among 300 patients who received multi-channel cochlear implants from 1996 to 2002 in Beijing Tongren Hospital, 15 patients were diagnosed with Mondini malformation. A retrospective analysis was performed dealing with the surgical techniques, mapping and rehabilitations characteristics after surgery. 15 patients with normal cochlear structure are consider as control group. Gusher is found more common than the normal cochlear implantation, most of them are serious. The electrodes are inserted in the "cochleostomy" in full length of 13 Patients, 2 pairs of electrodes remains outside of "cochleostomy" in 2 patients. No serious complications occurred after implantation. All patients have auditory sensations. The impedance of the electrodes, the T level, C level and the hearing threshold are similar with the normal cochlear implantation group. The results have no significant difference in compare with normal cochlear group(P > 0.05). Multi-channel cochlear implantation could be performed safely in patients with Mondini malformation. The primary outcome for patients with Mondini malformation are similar to those with normal cochlear structure following the multi-channel cochlear implantation.

  6. Cochlear implantation in a bilateral Mondini dysplasia.

    Science.gov (United States)

    Turrini, M; Orzan, E; Gabana, M; Genovese, E; Arslan, E; Fisch, U

    1997-01-01

    We report the speech perception progress and programming procedures of a case of congenital profound deafness and bilateral Mondini dysplasia implanted with a Nucleus 20 + 2 cochlear implant at the age of six. Unclear relations between electrodes array and cochlear partition made implant programming difficult and non-standard procedures were set. Cochlear implantation may give excellent rehabilitative results also in cochleae with malformation.

  7. Trends in Cochlear Implants

    OpenAIRE

    Zeng, Fan-Gang

    2004-01-01

    More than 60,000 people worldwide use cochlear implants as a means to restore functional hearing. Although individual performance variability is still high, an average implant user can talk on the phone in a quiet environment. Cochlear-implant research has also matured as a field, as evidenced by the exponential growth in both the patient population and scientific publication. The present report examines current issues related to audiologic, clinical, engineering, anatomic, and physiologic as...

  8. Modeling the electrode-neuron interface of cochlear implants: effects of neural survival, electrode placement, and the partial tripolar configuration.

    Science.gov (United States)

    Goldwyn, Joshua H; Bierer, Steven M; Bierer, Julie Arenberg

    2010-09-01

    The partial tripolar electrode configuration is a relatively novel stimulation strategy that can generate more spatially focused electric fields than the commonly used monopolar configuration. Focused stimulation strategies should improve spectral resolution in cochlear implant users, but may also be more sensitive to local irregularities in the electrode-neuron interface. In this study, we develop a practical computer model of cochlear implant stimulation that can simulate neural activation in a simplified cochlear geometry and we relate the resulting patterns of neural activity to basic psychophysical measures. We examine how two types of local irregularities in the electrode-neuron interface, variations in spiral ganglion nerve density and electrode position within the scala tympani, affect the simulated neural activation patterns and how these patterns change with electrode configuration. The model shows that higher partial tripolar fractions activate more spatially restricted populations of neurons at all current levels and require higher current levels to excite a given number of neurons. We find that threshold levels are more sensitive at high partial tripolar fractions to both types of irregularities, but these effects are not independent. In particular, at close electrode-neuron distances, activation is typically more spatially localized which leads to a greater influence of neural dead regions. Copyright (c) 2010 Elsevier B.V. All rights reserved.

  9. What Does Music Sound Like for a Cochlear Implant User?

    Science.gov (United States)

    Jiam, Nicole T; Caldwell, Meredith T; Limb, Charles J

    2017-09-01

    Cochlear implant research and product development over the past 40 years have been heavily focused on speech comprehension with little emphasis on music listening and enjoyment. The relatively little understanding of how music sounds in a cochlear implant user stands in stark contrast to the overall degree of importance the public places on music and quality of life. The purpose of this article is to describe what music sounds like to cochlear implant users, using a combination of existing research studies and listener descriptions. We examined the published literature on music perception in cochlear implant users, particularly postlingual cochlear implant users, with an emphasis on the primary elements of music and recorded music. Additionally, we administered an informal survey to cochlear implant users to gather first-hand descriptions of music listening experience and satisfaction from the cochlear implant population. Limitations in cochlear implant technology lead to a music listening experience that is significantly distorted compared with that of normal hearing listeners. On the basis of many studies and sources, we describe how music is frequently perceived as out-of-tune, dissonant, indistinct, emotionless, and weak in bass frequencies, especially for postlingual cochlear implant users-which may in part explain why music enjoyment and participation levels are lower after implantation. Additionally, cochlear implant users report difficulty in specific musical contexts based on factors including but not limited to genre, presence of lyrics, timbres (woodwinds, brass, instrument families), and complexity of the perceived music. Future research and cochlear implant development should target these areas as parameters for improvement in cochlear implant-mediated music perception.

  10. [The development of musicality in children after cochlear implantation].

    Science.gov (United States)

    Zheng, Yan; Liu, Bo; Dong, Ruijuan; Xu, Tianqiu; Chen, Jing; Chen, Xuejing; Zhong, Yan; Meng, Chao; Wang, Hong; Chen, Xueqing

    2014-08-01

    The purpose of this study is to analyze the development of musicality in children after cochlear implantation, and provide a clinical database for the evaluation of their musicality. Twenty-six children with cochlear implants (CI group) participated in this research. They received cochlear implants at the age of 11 to 68 months with a mean of 35.6 months. Seventy-six infants as a control group aged from 1 to 24 months with a mean of 6.1 months participated in this study, whose hearing were considered normal by passing the case history collection, high-risk registers for hearing loss and hearing screening using DPOAE. The music and young children with CIs: Musicality Rating Scale was used to evaluate their musicality. The evaluation was performed before cochlear implantation and 1, 3, 6, 9, 12, 24 months after cochlear implantation for children with cochlear implants. The evaluation was also performed at 1, 3, 6, 9, 12, 24 months for children with normal hearing. The mean scores of musicality showed significant improvements with time of CI use for CI group (Pmusicality also showed significant improvements with time for control group (P0.05). Significant difference was noted between the two groups at 24 months (Pmusicality of children with cochlear implants improved significantly with time after cochlear implantation. The most rapid growth was found in the first year after cochlear implantation.

  11. New Criteria of Indication and Selection of Patients to Cochlear Implant

    Directory of Open Access Journals (Sweden)

    André L. L. Sampaio

    2011-01-01

    Full Text Available Numerous changes continue to occur in cochlear implant candidacy. In general, these have been accompanied by concomitant and satisfactory changes in surgical techniques. Together, this has advanced the utility and safety of cochlear implantation. Most devices are now approved for use in patients with severe to profound unilateral hearing loss rather then the prior requirement of a bilateral profound loss. Furthermore, studies have begun utilizing short electrode arrays for shallow insertion in patients with considerable low-frequency residual hearing. This technique will allow the recipient to continue to use acoustically amplified hearing for the low frequencies simultaneously with a cochlear implant for the high frequencies. The advances in design of, and indications for, cochlear implants have been matched by improvements in surgical techniques and decrease in complications. The resulting improvements in safety and efficacy have further encouraged the use of these devices. This paper will review the new concepts in the candidacy of cochlear implant. Medline data base was used to search articles dealing with the following topics: cochlear implant in younger children, cochlear implant and hearing preservation, cochlear implant for unilateral deafness and tinnitus, genetic hearing loss and cochlear implant, bilateral cochlear implant, neuropathy and cochlear implant and neural plasticity, and the selection of patients for cochlear implant.

  12. Remote programming of cochlear implants: a telecommunications model.

    Science.gov (United States)

    McElveen, John T; Blackburn, Erin L; Green, J Douglas; McLear, Patrick W; Thimsen, Donald J; Wilson, Blake S

    2010-09-01

    Evaluate the effectiveness of remote programming for cochlear implants. Retrospective review of the cochlear implant performance for patients who had undergone mapping and programming of their cochlear implant via remote connection through the Internet. Postoperative Hearing in Noise Test and Consonant/Nucleus/Consonant word scores for 7 patients who had undergone remote mapping and programming of their cochlear implant were compared with the mean scores of 7 patients who had been programmed by the same audiologist over a 12-month period. Times required for remote and direct programming were also compared. The quality of the Internet connection was assessed using standardized measures. Remote programming was performed via a virtual private network with a separate software program used for video and audio linkage. All 7 patients were programmed successfully via remote connectivity. No untoward patient experiences were encountered. No statistically significant differences could be found in comparing postoperative Hearing in Noise Test and Consonant/Nucleus/Consonant word scores for patients who had undergone remote programming versus a similar group of patients who had their cochlear implant programmed directly. Remote programming did not require a significantly longer programming time for the audiologist with these 7 patients. Remote programming of a cochlear implant can be performed safely without any deterioration in the quality of the programming. This ability to remotely program cochlear implant patients gives the potential to extend cochlear implantation to underserved areas in the United States and elsewhere.

  13. Response properties of the refractory auditory nerve fiber.

    Science.gov (United States)

    Miller, C A; Abbas, P J; Robinson, B K

    2001-09-01

    The refractory characteristics of auditory nerve fibers limit their ability to accurately encode temporal information. Therefore, they are relevant to the design of cochlear prostheses. It is also possible that the refractory property could be exploited by prosthetic devices to improve information transfer, as refractoriness may enhance the nerve's stochastic properties. Furthermore, refractory data are needed for the development of accurate computational models of auditory nerve fibers. We applied a two-pulse forward-masking paradigm to a feline model of the human auditory nerve to assess refractory properties of single fibers. Each fiber was driven to refractoriness by a single (masker) current pulse delivered intracochlearly. Properties of firing efficiency, latency, jitter, spike amplitude, and relative spread (a measure of dynamic range and stochasticity) were examined by exciting fibers with a second (probe) pulse and systematically varying the masker-probe interval (MPI). Responses to monophasic cathodic current pulses were analyzed. We estimated the mean absolute refractory period to be about 330 micros and the mean recovery time constant to be about 410 micros. A significant proportion of fibers (13 of 34) responded to the probe pulse with MPIs as short as 500 micros. Spike amplitude decreased with decreasing MPI, a finding relevant to the development of computational nerve-fiber models, interpretation of gross evoked potentials, and models of more central neural processing. A small mean decrement in spike jitter was noted at small MPI values. Some trends (such as spike latency-vs-MPI) varied across fibers, suggesting that sites of excitation varied across fibers. Relative spread was found to increase with decreasing MPI values, providing direct evidence that stochastic properties of fibers are altered under conditions of refractoriness.

  14. Cochlear Implants

    Science.gov (United States)

    ... NIDCD A cochlear implant is a small, complex electronic device that can help to provide a sense ... Hearing Aids Retinitis Pigmentosa - National Eye Institute Telecommunications Relay Services Usher Syndrome Your Baby's Hearing Screening News ...

  15. Electrophysiology of Extraocular Cranial Nerves: Oculomotor, Trochlear, and Abducens Nerve.

    Science.gov (United States)

    Hariharan, Praveen; Balzer, Jeffery R; Anetakis, Katherine; Crammond, Donald J; Thirumala, Parthasarathy D

    2018-01-01

    The utility of extraocular cranial nerve electrophysiologic recordings lies primarily in the operating room during skull base surgeries. Surgical manipulation during skull base surgeries poses a risk of injury to multiple cranial nerves, including those innervating extraocular muscles. Because tumors distort normal anatomic relationships, it becomes particularly challenging to identify cranial nerve structures. Studies have reported the benefits of using intraoperative spontaneous electromyographic recordings and compound muscle action potentials evoked by electrical stimulation in preventing postoperative neurologic deficits. Apart from surgical applications, electromyography of extraocular muscles has also been used to guide botulinum toxin injections in patients with strabismus and as an adjuvant diagnostic test in myasthenia gravis. In this article, we briefly review the rationale, current available techniques to monitor extraocular cranial nerves, technical difficulties, clinical and surgical applications, as well as future directions for research.

  16. Evaluation of the Slope of Amplitude Growth Function Changes of the Electrically Evoked Action Potential in Three Months after Receiving the Device in Children with Cochlear Implant

    Directory of Open Access Journals (Sweden)

    Ali Reza Pourjavid

    2012-04-01

    Full Text Available Objective: In neural response telemetry, intracochlear electrodes stimulate the auditory nerve and record the neural responses. The electrical stimulation is sent to the auditory nerve by an electrode and the resulted response, called electrically evoked compound action potential, is recorded by an adjacent electrode. The most important clinical applications of this test are evaluation and monitoring the intra and postoperative responses of auditory nerve and help to primary setting of speech processor. The aim of this study was evaluating the potential's slope of amplitude growth function changes three monthes after receiving the devise in pediatric cochlear implant recipients. Materials & Methods: This longitudinal study evaluated the potentials' slope of amplitude growth function changes in four given electrodes in four sessions after receiving the devise by approximately one month's intervals in all of the children who implanted in Amir Alam and Hazrat-e-Rasoul hospitals in 2007, July to December. Friedman test was used to analyse the results. Results: Electrically evoked compound action potential's mean slope of each electrode was more in later sessions relative to first session, while there was significant difference between the 1st and the other electrodes’ responses in every session (P<0.05. Conclusion: The reliabiliy of the responses results in more assurance of clinician to fit the speech processor for along time. Better responses in apical electrodes may lead to develope an effective coding strategy.

  17. [Cochlear implant treatment in Germany].

    Science.gov (United States)

    Jacob, R; Stelzig, Y

    2013-01-01

    Restoration of impaired auditory function through cochlear implant is possible, with high reliably and great success. Nevertheless, there are regular disputes between patients and insurance companies due to high costs. In Germany, approx. 1.9 Mio. people are severely hearing impaired. It can be estimated that for adequate hearing rehabilitation about 30,000 cochlear implants/year are necessary. Currently, less than 10% of those affected are offered cochlear implant. A handicap is defined if there is deviation from normal hearing for more than 6 months. This sets a time frame for the supply with cochlear implant after sudden deafness. The professional code requires to advice all medical options to a person seeking help for hearing loss. This includes benefit-risk consideration. At this point, the economic aspect plays no role. The indication for medical treatment is only subject to the treating physician and should not be modified by non-physicians or organizations. It should be noted that a supply of hearing aids is qualitatively different to the help from a cochlear implant, which provides a restoration of lost function. In social law (SGB V and IX) doctors are requested to advise and recommend all measures which contribute to normal hearing (both sides). This indicates that doctors may be prosecuted for not offering help when medically possible, just because health insurance employees did not approve the cost balance. The current situation, with insufficient medical care for the hearing impaired, needs clarifying. To do this, patients, health insurance companies, the political institutions, legislation and professional societies need to accept their responsibilities.

  18. Deafblind People's Experiences of Cochlear Implantation

    Science.gov (United States)

    Soper, Janet

    2006-01-01

    Cochlear implants are electronic devices that create the sensation of hearing in those who cannot obtain any benefit from conventional hearing aids. This article examines the experience of cochlear implantation in a select group of individuals with acquired deafblindness, focusing on three key themes: access to communication, information and…

  19. Activity patterns of cochlear ganglion neurones in the starling.

    Science.gov (United States)

    Manley, G A; Gleich, O; Leppelsack, H J; Oeckinghaus, H

    1985-09-01

    Spontaneous activity and responses to simple tonal stimuli were studied in cochlear ganglion neurones of the starling. Both regular and irregular spontaneous activity were recorded. Non-auditory cells have their origin in the macula lagenae. Mean spontaneous rate for auditory cells (all irregularly spiking) was 45 spikes s-1. In half the units having characteristic frequencies (CFs) less than 1.5 kHz, time-interval histograms (TIHs) of spontaneous activity showed regularly-spaced peaks or 'preferred' intervals. The spacing of the peak intervals was, on average, 15% greater than the CF-period interval of the respective units. In TIH of lower-frequency cells without preferred intervals, the modal interval was also on average about 15% longer than the CF-period interval. Apparently, the resting oscillation frequency of these cells lies below their CF. Tuning curves (TCs) of neurones to short tone bursts show no systematic asymmetry as in mammals. Below CF 1 kHz, the low-frequency flanks of the TCs are, on average, steeper than the high-frequency flanks. Above CF 1 kHz, the reverse is true. The cochlear ganglion and nerve are tonotopically organized. Low-frequency fibres arise apically in the papilla basilaris and are found near non-auditory (lagenar) fibres. Discharge rates to short tones were monotonically related to sound pressure level. Saturation rates often exceeded 300 spikes s-1. 'On-off' responses and primary suppression of spontaneous activity were observed. A direct comparison of spontaneous activity and tuning-curve symmetry revealed that, apart from quantitative differences, fundamental qualitative differences exist between starling and guinea-pig primary afferents.

  20. [Cochlear implantation in patients with Waardenburg syndrome type II].

    Science.gov (United States)

    Wan, Liangcai; Guo, Menghe; Chen, Shuaijun; Liu, Shuangriu; Chen, Hao; Gong, Jian

    2010-05-01

    To describe the multi-channel cochlear implantation in patients with Waardenburg syndrome including surgeries, pre and postoperative hearing assessments as well as outcomes of speech recognition. Multi-channel cochlear implantation surgeries have been performed in 12 cases with Waardenburg syndrome type II in our department from 2000 to 2008. All the patients received multi-channel cochlear implantation through transmastoid facial recess approach. The postoperative outcomes of 12 cases were compared with 12 cases with no inner ear malformation as a control group. The electrodes were totally inserted into the cochlear successfully, there was no facial paralysis and cerebrospinal fluid leakage occurred after operation. The hearing threshold in this series were similar to that of the normal cochlear implantation. After more than half a year of speech rehabilitation, the abilities of speech discrimination and spoken language of all the patients were improved compared with that of preoperation. Multi-channel cochlear implantation could be performed in the cases with Waardenburg syndrome, preoperative hearing and images assessments should be done.

  1. Tinnitus with a normal audiogram: Relation to noise exposure but no evidence for cochlear synaptopathy.

    Science.gov (United States)

    Guest, Hannah; Munro, Kevin J; Prendergast, Garreth; Howe, Simon; Plack, Christopher J

    2017-02-01

    In rodents, exposure to high-level noise can destroy synapses between inner hair cells and auditory nerve fibers, without causing hair cell loss or permanent threshold elevation. Such "cochlear synaptopathy" is associated with amplitude reductions in wave I of the auditory brainstem response (ABR) at moderate-to-high sound levels. Similar ABR results have been reported in humans with tinnitus and normal audiometric thresholds, leading to the suggestion that tinnitus in these cases might be a consequence of synaptopathy. However, the ABR is an indirect measure of synaptopathy and it is unclear whether the results in humans reflect the same mechanisms demonstrated in rodents. Measures of noise exposure were not obtained in the human studies, and high frequency audiometric loss may have impacted ABR amplitudes. To clarify the role of cochlear synaptopathy in tinnitus with a normal audiogram, we recorded ABRs, envelope following responses (EFRs), and noise exposure histories in young adults with tinnitus and matched controls. Tinnitus was associated with significantly greater lifetime noise exposure, despite close matching for age, sex, and audiometric thresholds up to 14 kHz. However, tinnitus was not associated with reduced ABR wave I amplitude, nor with significant effects on EFR measures of synaptopathy. These electrophysiological measures were also uncorrelated with lifetime noise exposure, providing no evidence of noise-induced synaptopathy in this cohort, despite a wide range of exposures. In young adults with normal audiograms, tinnitus may be related not to cochlear synaptopathy but to other effects of noise exposure. Copyright © 2016 The Authors. Published by Elsevier B.V. All rights reserved.

  2. Efter cochlear implant

    DEFF Research Database (Denmark)

    Højen, Anders

    Dit barn har netop fået et cochlear implant. Hvad nu? Skal barnet fokusere udelukkende på at lære talt sprog, eller skal det også lære/fortsætte med tegnsprog eller støttetegn? Det er et vanskeligt spørgsmål, og før valget foretages, er det vigtigt at vurdere hvilke konsekvenser valget har, dels...... for den sproglige udvikling isoleret set, og dels for barnets udvikling ud fra en helhedsbetragtning. Dette indlæg fokuserer på, hvilke forventninger man kan have til cochlear implant-brugeres sproglige udvikling med talt sprog alene, hhv. med to sprog (tale og tegn). Disse forventninger er baseret på...

  3. Polymer Coatings of Cochlear Implant Electrode Surface - An Option for Improving Electrode-Nerve-Interface by Blocking Fibroblast Overgrowth.

    Directory of Open Access Journals (Sweden)

    C Hadler

    Full Text Available Overgrowth of connective tissue and scar formation induced by the electrode array insertion increase the impedance and, thus, diminish the interactions between neural probes as like cochlear implants (CI and the target tissue. Therefore, it is of great clinical interest to modify the carrier material of the electrodes to improve the electrode nerve interface for selective cell adhesion. On one side connective tissue growth needs to be reduced to avoid electrode array encapsulation, on the other side the carrier material should not compromise the interaction with neuronal cells. The present in vitro-study qualitatively and quantitatively characterises the interaction of fibroblasts, glial cells and spiral ganglion neurons (SGN with ultrathin poly(N,N-dimethylacrylamide (PDMAA, poly(2-ethyloxazoline (PEtOx and poly([2-methacryloyloxyethyl]trimethylammoniumchlorid (PMTA films immobilised onto glass surfaces using a photoreactive anchor layer. The layer thickness and hydrophilicity of the polymer films were characterised by ellipsometric and water contact angle measurement. Moreover the topography of the surfaces was investigated using atomic force microscopy (AFM. The neuronal and non-neuronal cells were dissociated from spiral ganglions of postnatal rats and cultivated for 48 h on top of the polymer coatings. Immunocytochemical staining of neuronal and intermediary filaments revealed that glial cells predominantly attached on PMTA films, but not on PDMAA and PEtOx monolayers. Hereby, strong survival rates and neurite outgrowth were only found on PMTA, whereas PDMAA and PEtOx coatings significantly reduced the SG neuron survival and neuritogenesis. As also shown by scanning electron microscopy (SEM SGN strongly survived and retained their differentiated phenotype only on PMTA. In conclusion, survival and neuritogenesis of SGN may be associated with the extent of the glial cell growth. Since PMTA was the only of the polar polymers used in this study

  4. Malformation of the eighth cranial nerve in children.

    Science.gov (United States)

    de Paula-Vernetta, Carlos; Muñoz-Fernández, Noelia; Mas-Estellés, Fernando; Guzmán-Calvete, Abel; Cavallé-Garrido, Laura; Morera-Pérez, Constantino

    2016-01-01

    Prevalence of congenital sensorineural hearing loss (SNHL) is approximately 1.5-6 in every 1,000 newborns. Dysfunction of the auditory nerve (auditory neuropathy) may be involved in up to 1%-10% of cases; hearing losses because of vestibulocochlear nerve (VCN) aplasia are less frequent. The objectives of this study were to describe clinical manifestations, hearing thresholds and aetiology of children with SNHL and VCN aplasia. We present 34 children (mean age 20 months) with auditory nerve malformation and profound HL taken from a sample of 385 children implanted in a 10-year period. We studied demographic characteristics, hearing, genetics, risk factors and associated malformations (Casselman's and Sennaroglu's classifications). Data were processed using a bivariate descriptive statistical analysis (P<.05). Of all the cases, 58.8% were bilateral (IIa/IIa and I/I were the most common). Of the unilateral cases, IIb was the most frequent. Auditory screening showed a sensitivity of 77.4%. A relationship among bilateral cases and systemic pathology was observed. We found a statistically significant difference when comparing hearing loss impairment and patients with different types of aplasia as defined by Casselman's classification. Computed tomography (CT) scan yielded a sensitivity of 46.3% and a specificity of 85.7%. However, magnetic resonance imaging (MRI) was the most sensitive imaging test. Ten percent of the children in a cochlear implant study had aplasia or hypoplasia of the auditory nerve. The degree of auditory loss was directly related to the different types of aplasia (Casselman's classification) Although CT scan and MRI are complementary, the MRI is the test of choice for detecting auditory nerve malformation. Copyright © 2016 Elsevier España, S.L.U. and Sociedad Española de Otorrinolaringología y Cirugía de Cabeza y Cuello. All rights reserved.

  5. Evaluating cochlear implant trauma to the scala vestibuli.

    Science.gov (United States)

    Adunka, O; Kiefer, J; Unkelbach, M H; Radeloff, A; Gstoettner, W

    2005-04-01

    Placement of cochlear implant electrodes into the scala vestibuli may be intentional, e.g. in case of blocked scala tympani or unintentional as a result of trauma to the basilar membrane or erroneous location of the cochieostomy. The aim of this study was to evaluate the morphological consequences and cochlear trauma after implantation of different cochlear implant electrode arrays in the scala vestibuli. Human temporal bone study with histological and radiological evaluation. Twelve human cadaver temporal bones were implanted with different cochlear implant electrodes. Implanted bones were processed using a special method to section undecalcified bone. Cochlear trauma and intracochlear positions. All implanted electrodes were implanted into the scala vestibuli using a special approach that allows direct scala vestibuli insertions. Fractures of the osseous spiral lamina were evaluated in some bones in the basal cochlear regions. In most electrodes, delicate structures of the organ of Corti were left intact, however, Reissner's membrane was destroyed in all specimens and the electrode lay upon the tectorial membrane. In some bones the organ of Corti was destroyed. Scala vestibuli insertions did not cause severe trauma to osseous or neural structures, thus preserving the basis for electrostimulation of the cochlea. However, destruction of Reissner's membrane and impact on the Organ of Corti can be assumed to destroy residual hearing.

  6. The Summating Potential Is a Reliable Marker of Electrode Position in Electrocochleography: Cochlear Implant as a Theragnostic Probe.

    Science.gov (United States)

    Helmstaedter, Victor; Lenarz, Thomas; Erfurt, Peter; Kral, Andrej; Baumhoff, Peter

    2017-12-14

    For the increasing number of cochlear implantations in subjects with residual hearing, hearing preservation, and thus the prevention of implantation trauma, is crucial. A method for monitoring the intracochlear position of a cochlear implant (CI) and early indication of imminent cochlear trauma would help to assist the surgeon to achieve this goal. The aim of this study was to evaluate the reliability of the different electric components recorded by an intracochlear electrocochleography (ECochG) as markers for the cochleotopic position of a CI. The measurements were made directly from the CI, combining intrasurgical diagnostics with the therapeutical use of the CI, thus, turning the CI into a "theragnostic probe." Intracochlear ECochGs were measured in 10 Dunkin Hartley guinea pigs of either sex, with normal auditory brainstem response thresholds. All subjects were fully implanted (4 to 5 mm) with a custom six contact CI. The ECochG was recorded simultaneously from all six contacts with monopolar configuration (retroauricular reference electrode). The gross ECochG signal was filtered off-line to separate three of its main components: compound action potential, cochlear microphonic, and summating potential (SP). Additionally, five cochleae were harvested and histologically processed to access the spatial position of the CI contacts. Both ECochG data and histological reconstructions of the electrode position were fitted with the Greenwood function to verify the reliability of the deduced cochleotopic position of the CI. SPs could be used as suitable markers for the frequency position of the recording electrode with an accuracy of ±1/4 octave in the functioning cochlea, verified by histology. Cochlear microphonics showed a dependency on electrode position but were less reliable as positional markers. Compound action potentials were not suitable for CI position information but were sensitive to "cochlear health" (e.g., insertion trauma). SPs directly recorded from

  7. A Two-Microphone Noise Reduction System for Cochlear Implant Users with Nearby Microphones—Part I: Signal Processing Algorithm Design and Development

    Directory of Open Access Journals (Sweden)

    Marco Pelizzone

    2008-06-01

    Full Text Available Users of cochlear implant systems, that is, of auditory aids which stimulate the auditory nerve at the cochlea electrically, often complain about poor speech understanding in noisy environments. Despite the proven advantages of multimicrophone directional noise reduction systems for conventional hearing aids, only one major manufacturer has so far implemented such a system in a product, presumably because of the added power consumption and size. We present a physically small (intermicrophone distance 7 mm and computationally inexpensive adaptive noise reduction system suitable for behind-the-ear cochlear implant speech processors. Supporting algorithms, which allow the adjustment of the opening angle and the maximum noise suppression, are proposed and evaluated. A portable real-time device for test in real acoustic environments is presented.

  8. Effects of chronic furosemide on central neural hyperactivity and cochlear thresholds after cochlear trauma in guinea pig

    Directory of Open Access Journals (Sweden)

    Wilhelmina eMulders

    2014-08-01

    Full Text Available Increased neuronal spontaneous firing rates have been observed throughout the central auditory system after trauma to the cochlea and this hyperactivity is believed to be associated with the phantom perception of tinnitus. Previously we have shown in an animal model of hearing loss, that an acute injection with furosemide can significantly decrease hyperactivity after cochlear trauma and eliminate behavioural evidence of tinnitus of early onset. However, furosemide also has the potential to affect cochlear thresholds. In this paper we measured the effects of a chronic (daily injections for 7 days furosemide treatment on the spontaneous firing rate of inferior colliculus neurons and on cochlear thresholds in order to establish whether a beneficial effect on hyperactivity can be obtained without causing additional hearing loss. Guinea pigs were exposed to a 10 kHz, 124dB, 2 hour acoustic trauma, and after 5 days of recovery, were given daily i.p. injections of 80mg/kg furosemide or an equivalent amount of saline. The activity of single IC neurons was recorded 24 hours following the last injection. The furosemide treatment had no effect on cochlear thresholds compared to saline injections but did result in significant reductions in spontaneous firing rates recorded in inferior colliculus. These results that suggest a long term beneficial effect of furosemide on hyperactivity after cochlear trauma may be achievable without detrimental effects on hearing, which is important when considering therapeutic potential.

  9. The cochlear implant as a tinnitus treatment.

    Science.gov (United States)

    Vallés-Varela, Héctor; Royo-López, Juan; Carmen-Sampériz, Luis; Sebastián-Cortés, José M; Alfonso-Collado, Ignacio

    2013-01-01

    Tinnitus is a symptom of high prevalence in patients with cochlear pathology. We studied the evolution of tinnitus in patients undergoing unilateral cochlear implantation for treatment of profound hearing loss. This was a longitudinal, retrospective study of patients that underwent unilateral cochlear implantation and who had bilateral tinnitus. Tinnitus was assessed quantitatively and qualitatively before surgery and at 6 and 12 months after surgery. We evaluated 20 patients that underwent unilateral cochlear implantation with a Nucleus(®) CI24RE Contour Advance™ electrode device. During the periods in which the device was in operation, improvement or disappearance of tinnitus was evidenced in the ipsilateral ear in 65% of patients, and in the contralateral ear, in 50%. In periods in which the device was disconnected, improvement or disappearance of tinnitus was found in the ipsilateral ear in 50% of patients, and in the ear contralateral to the implant in 45% of the patients. In 10% of the patients, a new tinnitus appeared in the ipsilateral ear. The patients with profound hearing loss and bilateral tinnitus treated with unilateral cochlear implantation improved in a high percentage of cases, in the ipsilateral ear and in the contralateral ear. Copyright © 2012 Elsevier España, S.L. All rights reserved.

  10. Cochlear implants in children implanted in Jordan: A parental overview.

    Science.gov (United States)

    Alkhamra, Rana A

    2015-07-01

    Exploring the perspective of parents on the cochlear implant process in Jordan. Sixty parents of deaf children were surveyed on the information gathering process prior to cochlear implant surgery, and their implant outcome expectations post-surgery. Whether child or parent characteristics may impact parents' post-surgical expectations was explored. Although parents used a variety of information sources when considering a cochlear implant, the ear, nose and throat doctor comprised their major source of information (60%). Parents received a range of information prior to cochlear implant but agreed (93.3%) on the need for a multidisciplinary team approach. Post-surgically, parents' expected major developments in the areas of spoken language (97%), and auditory skills (100%). Receiving education in mainstream schools (92%) was expected too. Parents perceived the cochlear implant decision as the best decision they can make for their child (98.3%). A significant correlation was found between parents contentment with the cochlear implant decision and expecting developments in the area of reading and writing (r=0.7). Child's age at implantation and age at hearing loss diagnosis significantly affected parents' post-implant outcome expectations (pparents agree on the need for a comprehensive multidisciplinary team approach during the different stages of the cochlear implant process. Parents' education about cochlear implants prior to the surgery can affect their post-surgical outcome expectations. The parental perspective presented in this study can help professionals develop better understanding of parents' needs and expectations and henceforth improve their services and support during the different stages of the cochlear implant process. Copyright © 2015. Published by Elsevier Ireland Ltd.

  11. Comparison of outcomes in a case of bilateral cochlear implantation using devices manufactured by two different implant companies (Cochlear Corporation and Med-El).

    Science.gov (United States)

    Withers, S J; Gibson, W P; Greenberg, S L; Bray, M

    2011-05-01

    This paper reports a case of a patient who has had bilateral cochlear implants that have been manufactured by different cochlear implant companies (Cochlear Corporation and Med-El). Comparison of speech perception tests following single implant insertion and bilateral insertion (3 and 12 months). The patient was also interviewed to obtain a subjective opinion on their quality of hearing. The patient reported that their Med-El implant had better sound quality than their Cochlear Corporation implant. The speech perception tests however failed to show any difference. Despite no difference found with the objective tests hearing is very subjective and therefore the patient's opinion on the quality of sound is important. It is only a matter of time before other patients are fitted with bilateral cochlear implants from different companies and this information should be collated to allow comparison between manufacturers.

  12. [Inspecting the cochlear scala tympanic with flexible and semi-flexible micro-endoscope].

    Science.gov (United States)

    Zhang, Daoxcing; Zhang, Yankun

    2006-02-01

    Flexible and semi-flexible micro-endoscopes were used in cochlear scala tympani inspection , to explore their application in inner ear examination. Fifteen profound hearing loss patients preparing for cochlear implant were included in this study. During the operation, micro-endoscopy was performed after opening the cochlear scala tympani. And 1 mm diameter semi-flexible micro-endoscope could go as deep as 9 mm into the cochlear scala tympani, while 0. 5 mm diameter flexible micro-endoscope could go as deep as 25 mm. The inspecting results were compared with video recording. Using 0.5 mm flexible micro-endoscope, we canould check cochlear scala tympani with depth range of 15-25 mm, but the video imaging was not clear enough to examine the microstructure in the cochlear. With 1 mm diameter semi-flexible micro-endoscope, we could reach 9 mm deep into the cochlear. During the examination, we found 3 cases with calcification deposit in osseous spiral lamina, l case with granulation tissue in the lateral wall of scala tympani, no abnormal findings in the other 11 cases. Inspecting the cochlear scala tympani with 0.5 mm flexible micro-endoscope, even though we can reach the second circuit of the cochlear, it is difficult to find the pathology in the cochlear because of the poor video imaging. With 1 mm semi-flexible micro-endoscope, we can identify the microstructure of the cochlear clearly and find the pathologic changes, but the inserting depth was limited to 9 mm with limitation to examine the whole cochlear.

  13. Relationship Between Peripheral and Psychophysical Measures of Amplitude Modulation Detection in Cochlear Implant Users.

    Science.gov (United States)

    Tejani, Viral D; Abbas, Paul J; Brown, Carolyn J

    This study investigates the relationship between electrophysiological and psychophysical measures of amplitude modulation (AM) detection. Prior studies have reported both measures of AM detection recorded separately from cochlear implant (CI) users and acutely deafened animals, but no study has made both measures in the same CI users. Animal studies suggest a progressive loss of high-frequency encoding as one ascends the auditory pathway from the auditory nerve to the cortex. Because the CI speech processor uses the envelope of an ongoing acoustic signal to modulate pulse trains that are subsequently delivered to the intracochlear electrodes, it is of interest to explore auditory nerve responses to modulated stimuli. In addition, psychophysical AM detection abilities have been correlated with speech perception outcomes. Thus, the goal was to explore how the auditory nerve responds to AM stimuli and to relate those physiologic measures to perception. Eight patients using Cochlear Ltd. Implants participated in this study. Electrically evoked compound action potentials (ECAPs) were recorded using a 4000 pps pulse train that was sinusoidally amplitude modulated at 125, 250, 500, and 1000 Hz rates. Responses were measured for each pulse over at least one modulation cycle for an apical, medial, and basal electrode. Psychophysical modulation detection thresholds (MDTs) were also measured via a three-alternative forced choice, two-down, one-up adaptive procedure using the same modulation frequencies and electrodes. ECAPs were recorded from individual pulses in the AM pulse train. ECAP amplitudes varied sinusoidally, reflecting the sinusoidal variation in the stimulus. A modulated response amplitude (MRA) metric was calculated as the difference in the maximal and minimum ECAP amplitudes over the modulation cycles. MRA increased as modulation frequency increased, with no apparent cutoff (up to 1000 Hz). In contrast, MDTs increased as the modulation frequency increased. This

  14. Tinnitus after Simultaneous and Sequential Bilateral Cochlear Implantation.

    Science.gov (United States)

    Ramakers, Geerte G J; Kraaijenga, Véronique J C; Smulders, Yvette E; van Zon, Alice; Stegeman, Inge; Stokroos, Robert J; Free, Rolien H; Frijns, Johan H M; Huinck, Wendy J; Van Zanten, Gijsbert A; Grolman, Wilko

    2017-01-01

    There is an ongoing global discussion on whether or not bilateral cochlear implantation should be standard care for bilateral deafness. Contrary to unilateral cochlear implantation, however, little is known about the effect of bilateral cochlear implantation on tinnitus. To investigate tinnitus outcomes 1 year after bilateral cochlear implantation. Secondarily, to compare tinnitus outcomes between simultaneous and sequential bilateral cochlear implantation and to investigate long-term follow-up (3 years). This study is a secondary analysis as part of a multicenter randomized controlled trial. Thirty-eight postlingually deafened adults were included in the original trial, in which the presence of tinnitus was not an inclusion criterion. All participants received cochlear implants (CIs) because of profound hearing loss. Nineteen participants received bilateral CIs simultaneously and 19 participants received bilateral CIs sequentially with an inter-implant interval of 2 years. The prevalence and severity of tinnitus before and after simultaneous and sequential bilateral cochlear implantation were measured preoperatively and each year after implantation with the Tinnitus Handicap Inventory (THI) and Tinnitus Questionnaire (TQ). The prevalence of preoperative tinnitus was 42% (16/38). One year after bilateral implantation, there was a median difference of -8 (inter-quartile range (IQR): -28 to 4) in THI score and -9 (IQR: -17 to -9) in TQ score in the participants with preoperative tinnitus. Induction of tinnitus occurred in five participants, all in the simultaneous group, in the year after bilateral implantation. Although the preoperative and also the postoperative median THI and TQ scores were higher in the simultaneous group, the median difference scores were equal in both groups. In the simultaneous group, tinnitus scores fluctuated in the 3 years after implantation. In the sequential group, four patients had an additional benefit of the second CI: a total

  15. Exercise training improves functional recovery and motor nerve conduction velocity after sciatic nerve crush lesion in the rat

    NARCIS (Netherlands)

    Gispen, W.H.; Meeteren, N.L.U.; Brakkee, J.H.; Hamers, F.P.T.; Helders, P.J.M.

    1997-01-01

    Objective: To observe the effects of exercise training on recuperation of sensorimotor function in the early phase of regeneration, and to monitor the long-term effects of exercise on electrophysiological aspects of the regenerating nerve. Design: After sciatic nerve crush in 20 male Wistar rats,

  16. The Hearing Outcomes of Cochlear Implantation in Waardenburg Syndrome.

    Science.gov (United States)

    Koyama, Hajime; Kashio, Akinori; Sakata, Aki; Tsutsumiuchi, Katsuhiro; Matsumoto, Yu; Karino, Shotaro; Kakigi, Akinobu; Iwasaki, Shinichi; Yamasoba, Tatsuya

    2016-01-01

    Objectives. This study aimed to determine the feasibility of cochlear implantation for sensorineural hearing loss in patients with Waardenburg syndrome. Method. A retrospective chart review was performed on patients who underwent cochlear implantation at the University of Tokyo Hospital. Clinical classification, genetic mutation, clinical course, preoperative hearing threshold, high-resolution computed tomography of the temporal bone, and postoperative hearing outcome were assessed. Result. Five children with Waardenburg syndrome underwent cochlear implantation. The average age at implantation was 2 years 11 months (ranging from 1 year 9 months to 6 years 3 months). Four patients had congenital profound hearing loss and one patient had progressive hearing loss. Two patients had an inner ear malformation of cochlear incomplete partition type 2. No surgical complication or difficulty was seen in any patient. All patients showed good hearing outcome postoperatively. Conclusion. Cochlear implantation could be a good treatment option for Waardenburg syndrome.

  17. The Hearing Outcomes of Cochlear Implantation in Waardenburg Syndrome

    Directory of Open Access Journals (Sweden)

    Hajime Koyama

    2016-01-01

    Full Text Available Objectives. This study aimed to determine the feasibility of cochlear implantation for sensorineural hearing loss in patients with Waardenburg syndrome. Method. A retrospective chart review was performed on patients who underwent cochlear implantation at the University of Tokyo Hospital. Clinical classification, genetic mutation, clinical course, preoperative hearing threshold, high-resolution computed tomography of the temporal bone, and postoperative hearing outcome were assessed. Result. Five children with Waardenburg syndrome underwent cochlear implantation. The average age at implantation was 2 years 11 months (ranging from 1 year 9 months to 6 years 3 months. Four patients had congenital profound hearing loss and one patient had progressive hearing loss. Two patients had an inner ear malformation of cochlear incomplete partition type 2. No surgical complication or difficulty was seen in any patient. All patients showed good hearing outcome postoperatively. Conclusion. Cochlear implantation could be a good treatment option for Waardenburg syndrome.

  18. Histopathology of cryoballoon ablation-induced phrenic nerve injury.

    Science.gov (United States)

    Andrade, Jason G; Dubuc, Marc; Ferreira, Jose; Guerra, Peter G; Landry, Evelyn; Coulombe, Nicolas; Rivard, Lena; Macle, Laurent; Thibault, Bernard; Talajic, Mario; Roy, Denis; Khairy, Paul

    2014-02-01

    Hemi-diaphragmatic paralysis is the most common complication associated with cryoballoon ablation for atrial fibrillation, yet the histopathology of phrenic nerve injury has not been well described. A preclinical randomized study was conducted to characterize the histopathology of phrenic nerve injury induced by cryoballoon ablation and assess the potential for electromyographic (EMG) monitoring to limit phrenic nerve damage. Thirty-two dogs underwent cryoballoon ablation of the right superior pulmonary vein with the objective of inducing phrenic nerve injury. Animals were randomized 1:1 to standard monitoring (i.e., interruption of ablation upon reduction in diaphragmatic motion) versus EMG guidance (i.e., cessation of ablation upon a 30% reduction in the diaphragmatic compound motor action potential [CMAP] amplitude). The acute procedural endpoint was achieved in all dogs. Phrenic nerve injury was characterized by Wallerian degeneration, with subperineural injury to large myelinated axons and evidence of axonal regeneration. The degree of phrenic nerve injury paralleled the reduction in CMAP amplitude (P = 0.007). Animals randomized to EMG guidance had a lower incidence of acute hemi-diaphragmatic paralysis (50% vs 100%; P = 0.001), persistent paralysis at 30 days (21% vs 75%; multivariate odds ratio 0.12, 95% confidence interval [0.02, 0.69], P = 0.017), and a lesser severity of histologic injury (P = 0.001). Mature pulmonary vein ablation lesion characteristics, including circumferentiality and transmurality, were similar in both groups. Phrenic nerve injury induced by cryoballoon ablation is axonal in nature and characterized by Wallerian degeneration, with potential for recovery. An EMG-guided approach is superior to standard monitoring in limiting phrenic nerve damage. © 2013 Wiley Periodicals, Inc.

  19. Outcomes of cochlear implantation in deaf children of deaf parents: comparative study.

    Science.gov (United States)

    Hassanzadeh, S

    2012-10-01

    This retrospective study compared the cochlear implantation outcomes of first- and second-generation deaf children. The study group consisted of seven deaf, cochlear-implanted children with deaf parents. An equal number of deaf children with normal-hearing parents were selected by matched sampling as a reference group. Participants were matched based on onset and severity of deafness, duration of deafness, age at cochlear implantation, duration of cochlear implantation, gender, and cochlear implant model. We used the Persian Auditory Perception Test for the Hearing Impaired, the Speech Intelligibility Rating scale, and the Sentence Imitation Test, in order to measure participants' speech perception, speech production and language development, respectively. Both groups of children showed auditory and speech development. However, the second-generation deaf children (i.e. deaf children of deaf parents) exceeded the cochlear implantation performance of the deaf children with hearing parents. This study confirms that second-generation deaf children exceed deaf children of hearing parents in terms of cochlear implantation performance. Encouraging deaf children to communicate in sign language from a very early age, before cochlear implantation, appears to improve their ability to learn spoken language after cochlear implantation.

  20. Prevention and management of cochlear implant infections.

    Science.gov (United States)

    Gluth, Michael B; Singh, Rajesh; Atlas, Marcus D

    2011-11-01

    Understanding the issues of infection related to an implantable medical device is crucial to all cochlear implant teams. Furthermore, given the risk of central nervous system complications and the relatively high quantity of underlying resource investment associated with cochlear implantation, the stakes of infection are high. The optimal strategies to prevent and manage such infections are still evolving as good-quality prospective data to guide such management decisions are not yet abundant within the medical literature and many recommendations are based on retrospective reviews or anecdotal evidence. We will outline a general strategy to deal with cochlear implant-related infection based on both the authors' experience and the published literature.

  1. The group delay and suppression pattern of the cochlear microphonic potential recorded at the round window.

    Directory of Open Access Journals (Sweden)

    Wenxuan He

    Full Text Available BACKGROUND: It is commonly assumed that the cochlear microphonic potential (CM recorded from the round window (RW is generated at the cochlear base. Based on this assumption, the low-frequency RW CM has been measured for evaluating the integrity of mechanoelectrical transduction of outer hair cells at the cochlear base and for studying sound propagation inside the cochlea. However, the group delay and the origin of the low-frequency RW CM have not been demonstrated experimentally. METHODOLOGY/PRINCIPAL FINDINGS: This study quantified the intra-cochlear group delay of the RW CM by measuring RW CM and vibrations at the stapes and basilar membrane in gerbils. At low sound levels, the RW CM showed a significant group delay and a nonlinear growth at frequencies below 2 kHz. However, at high sound levels or at frequencies above 2 kHz, the RW CM magnitude increased proportionally with sound pressure, and the CM phase in respect to the stapes showed no significant group delay. After the local application of tetrodotoxin the RW CM below 2 kHz became linear and showed a negligible group delay. In contrast to RW CM phase, the BM vibration measured at location ∼2.5 mm from the base showed high sensitivity, sharp tuning, and nonlinearity with a frequency-dependent group delay. At low or intermediate sound levels, low-frequency RW CMs were suppressed by an additional tone near the probe-tone frequency while, at high sound levels, they were partially suppressed only at high frequencies. CONCLUSIONS/SIGNIFICANCE: We conclude that the group delay of the RW CM provides no temporal information on the wave propagation inside the cochlea, and that significant group delay of low-frequency CMs results from the auditory nerve neurophonic potential. Suppression data demonstrate that the generation site of the low-frequency RW CM shifts from apex to base as the probe-tone level increases.

  2. Gain and frequency tuning within the mouse cochlear apex

    Energy Technology Data Exchange (ETDEWEB)

    Oghalai, John S.; Raphael, Patrick D. [Department of Otolaryngology, Stanford University School of Medicine, Stanford, California (United States); Gao, Simon [Department of Otolaryngology, Stanford University School of Medicine, Stanford, California (United States); Department of Bioengineering, Rice University, Houston, Texas (United States); Lee, Hee Yoon [Department of Otolaryngology, Stanford University School of Medicine, Stanford, California (United States); Department of Electrical Engineering, Stanford University, Stanford, California (United States); Groves, Andrew K. [Department of Neuroscience, Department of Molecular and Human Genetics, and Program in Developmental Biology, Baylor College of Medicine, Houston, Texas (United States); Zuo, Jian [Department of Developmental Neurobiology, St. Jude Children’s Research Hospital, Memphis, Tennessee (United States); Applegate, Brian E. [Department of Biomedical Engineering, Texas A& M University, College Station, Texas (United States)

    2015-12-31

    Normal mammalian hearing requires cochlear outer hair cell active processes that amplify the traveling wave with high gain and sharp tuning, termed cochlear amplification. We have used optical coherence tomography to study cochlear amplification within the apical turn of the mouse cochlea. We measured not only classical basilar membrane vibratory tuning curves but also vibratory responses from the rest of the tissues that compose the organ of Corti. Basilar membrane tuning was sharp in live mice and broad in dead mice, whereas other regions of the organ of Corti demonstrated phase shifts consistent with additional filtering beyond that provided by basilar membrane mechanics. We use these experimental data to support a conceptual framework of how cochlear amplification is tuned within the mouse cochlear apex. We will also study transgenic mice with targeted mutations that affect different biomechanical aspects of the organ of Corti in an effort to localize the underlying processes that produce this additional filtering.

  3. Gain and frequency tuning within the mouse cochlear apex

    International Nuclear Information System (INIS)

    Oghalai, John S.; Raphael, Patrick D.; Gao, Simon; Lee, Hee Yoon; Groves, Andrew K.; Zuo, Jian; Applegate, Brian E.

    2015-01-01

    Normal mammalian hearing requires cochlear outer hair cell active processes that amplify the traveling wave with high gain and sharp tuning, termed cochlear amplification. We have used optical coherence tomography to study cochlear amplification within the apical turn of the mouse cochlea. We measured not only classical basilar membrane vibratory tuning curves but also vibratory responses from the rest of the tissues that compose the organ of Corti. Basilar membrane tuning was sharp in live mice and broad in dead mice, whereas other regions of the organ of Corti demonstrated phase shifts consistent with additional filtering beyond that provided by basilar membrane mechanics. We use these experimental data to support a conceptual framework of how cochlear amplification is tuned within the mouse cochlear apex. We will also study transgenic mice with targeted mutations that affect different biomechanical aspects of the organ of Corti in an effort to localize the underlying processes that produce this additional filtering

  4. A true minimally invasive approach for cochlear implantation: high accuracy in cranial base navigation through flat-panel-based volume computed tomography.

    Science.gov (United States)

    Majdani, Omid; Bartling, Soenke H; Leinung, Martin; Stöver, Timo; Lenarz, Minoo; Dullin, Christian; Lenarz, Thomas

    2008-02-01

    High-precision intraoperative navigation using high-resolution flat-panel volume computed tomography makes feasible the possibility of minimally invasive cochlear implant surgery, including cochleostomy. Conventional cochlear implant surgery is typically performed via mastoidectomy with facial recess to identify and avoid damage to vital anatomic landmarks. To accomplish this procedure via a minimally invasive approach--without performing mastoidectomy--in a precise fashion, image-guided technology is necessary. With such an approach, surgical time and expertise may be reduced, and hearing preservation may be improved. Flat-panel volume computed tomography was used to scan 4 human temporal bones. A drilling channel was planned preoperatively from the mastoid surface to the round window niche, providing a margin of safety to all functional important structures (e.g., facial nerve, chorda tympani, incus). Postoperatively, computed tomographic imaging and conventional surgical exploration of the drilled route to the cochlea were performed. All 4 specimens showed a cochleostomy located at the scala tympani anterior inferior to the round window. The chorda tympani was damaged in 1 specimen--this was preoperatively planned as a narrow facial recess was encountered. Using flat-panel volume computed tomography for image-guided surgical navigation, we were able to perform minimally invasive cochlear implant surgery defined as a narrow, single-channel mastoidotomy with cochleostomy. Although this finding is preliminary, it is technologically achievable.

  5. Neuronal differentiation of hair-follicle-bulge-derived stem cells co-cultured with mouse cochlear modiolus explants.

    Directory of Open Access Journals (Sweden)

    Timo Schomann

    Full Text Available Stem-cell-based repair of auditory neurons may represent an attractive therapeutic option to restore sensorineural hearing loss. Hair-follicle-bulge-derived stem cells (HFBSCs are promising candidates for this type of therapy, because they (1 have migratory properties, enabling migration after transplantation, (2 can differentiate into sensory neurons and glial cells, and (3 can easily be harvested in relatively high numbers. However, HFBSCs have never been used for this purpose. We hypothesized that HFBSCs can be used for cell-based repair of the auditory nerve and we have examined their migration and incorporation into cochlear modiolus explants and their subsequent differentiation. Modiolus explants obtained from adult wild-type mice were cultured in the presence of EF1α-copGFP-transduced HFBSCs, constitutively expressing copepod green fluorescent protein (copGFP. Also, modiolus explants without hair cells were co-cultured with DCX-copGFP-transduced HFBSCs, which demonstrate copGFP upon doublecortin expression during neuronal differentiation. Velocity of HFBSC migration towards modiolus explants was calculated, and after two weeks, co-cultures were fixed and processed for immunohistochemical staining. EF1α-copGFP HFBSC migration velocity was fast: 80.5 ± 6.1 μm/h. After arrival in the explant, the cells formed a fascicular pattern and changed their phenotype into an ATOH1-positive neuronal cell type. DCX-copGFP HFBSCs became green-fluorescent after integration into the explants, confirming neuronal differentiation of the cells. These results show that HFBSC-derived neuronal progenitors are migratory and can integrate into cochlear modiolus explants, while adapting their phenotype depending on this micro-environment. Thus, HFBSCs show potential to be employed in cell-based therapies for auditory nerve repair.

  6. [Emotional response to music by postlingually-deafened adult cochlear implant users].

    Science.gov (United States)

    Wang, Shuo; Dong, Ruijuan; Zhou, Yun; Li, Jing; Qi, Beier; Liu, Bo

    2012-10-01

    To assess the emotional response to music by postlingually-deafened adult cochlear implant users. Munich music questionnaire (MUMU) was used to match the music experience and the motivation of use of music between 12 normal-hearing and 12 cochlear implant subjects. Emotion rating test in Musical Sounds in Cochlear Implants (MuSIC) test battery was used to assess the emotion perception ability for both normal-hearing and cochlear implant subjects. A total of 15 pieces of music phases were used. Responses were given by selecting the rating scales from 1 to 10. "1" represents "very sad" feeling, and "10" represents "very happy feeling. In comparison with normal-hearing subjects, 12 cochlear implant subjects made less active use of music for emotional purpose. The emotion ratings for cochlear implant subjects were similar to normal-hearing subjects, but with large variability. Post-lingually deafened cochlear implant subjects on average performed similarly in emotion rating tasks relative to normal-hearing subjects, but their active use of music for emotional purpose was obviously less than normal-hearing subjects.

  7. United Kingdom national paediatric bilateral cochlear implant audit: preliminary results.

    Science.gov (United States)

    Cullington, Helen; Bele, Devyanee; Brinton, Julie; Lutman, Mark

    2013-11-01

    Prior to 2009, United Kingdom (UK) public funding was mainly only available for children to receive unilateral cochlear implants. In 2009, the National Institute for Health and Care Excellence published guidance for cochlear implantation following their review. According to these guidelines, all suitable children are eligible to have simultaneous bilateral cochlear implants or a sequential bilateral cochlear implant if they had received the first before the guidelines were published. Fifteen UK cochlear implant centres formed a consortium to carry out a multi-centre audit. The audit involves collecting data from simultaneously and sequentially implanted children at four intervals: before bilateral cochlear implants or before the sequential implant, 1, 2, and 3 years after bilateral implants. The measures include localization, speech recognition in quiet and background noise, speech production, listening, vocabulary, parental perception, quality of life, and surgical data including complications. The audit has now passed the 2-year point, and data have been received on 850 children. This article provides a first view of some data received up until March 2012.

  8. Tinnitus and Sleep Difficulties After Cochlear Implantation.

    Science.gov (United States)

    Pierzycki, Robert H; Edmondson-Jones, Mark; Dawes, Piers; Munro, Kevin J; Moore, David R; Kitterick, Pádraig T

    To estimate and compare the prevalence of and associations between tinnitus and sleep difficulties in a sample of UK adult cochlear implant users and those identified as potential candidates for cochlear implantation. The study was conducted using the UK Biobank resource, a population-based cohort of 40- to 69-year olds. Self-report data on hearing, tinnitus, sleep difficulties, and demographic variables were collected from cochlear implant users (n = 194) and individuals identified as potential candidates for cochlear implantation (n = 211). These "candidates" were selected based on (i) impaired hearing sensitivity, inferred from self-reported hearing aid use and (ii) impaired hearing function, inferred from an inability to report words accurately at negative signal to noise ratios on an unaided closed-set test of speech perception. Data on tinnitus (presence, persistence, and related distress) and on sleep difficulties were analyzed using logistic regression models controlling for gender, age, deprivation, and neuroticism. The prevalence of tinnitus was similar among implant users (50%) and candidates (52%; p = 0.39). However, implant users were less likely to report that their tinnitus was distressing at its worst (41%) compared with candidates (63%; p = 0.02). The logistic regression model suggested that this difference between the two groups could be explained by the fact that tinnitus was less persistent in implant users (46%) compared with candidates (72%; p reported difficulties with sleep were similar among implant users (75%) and candidates (82%; p = 0.28), but participants with tinnitus were more likely to report sleep difficulties than those without (p explanation is supported by the similar prevalence of sleep problems among implant users and potential candidates for cochlear implantation, despite differences between the groups in tinnitus persistence and related emotional distress. Cochlear implantation may therefore not be an appropriate intervention

  9. The preoperative imaging evaluation for cochlear implantation

    International Nuclear Information System (INIS)

    Liu Zhonglin; Wang Zhenchang; Fu Lin; Li Yong; Xian Junfang; Yang Bentao; Lan Baosen; Li Yongxin; Zheng Jun; Song Yan; Liu Bo; Chen Xueqing; He Haili

    2006-01-01

    Objective: To analyze CT and MRI findings of temporal bone and to evaluate preoperative diagnostic value for cochlear implantation. Methods: One hundred and sixty candidates for cochlear implantation were examined with axial CT scan, 64 of them also with coronal CT scan, and 119 patients with MRI. Results: All of 320 ears were well-aerated, and 206 ears had mastoid cavities extended posteriorly to the sigmoid sinus. The length from posterior-lateral tympanic wall to the outer cortex was (2.34±0.42) mm (left side) and (2.25±0.40) mm (right side) (U=1.887, P 1 and T 2 signal on MRI. The congenital malformations of inner ear occurred in 67 ears, including complete dysplasia in 1 ear, cochlear hypodysplasia in 6 ears, Mondini deformation in 5 ears, enlarged vestibular aqueduct in 40 ears, dysplastic semicircular canal and the vestibulae in 10 ears, and narrowing of internal auditory canal in 5 ears. Conclusion: Preoperative imaging examinations can provide critical information to ensure successful cochlear' implantation. (authors)

  10. Effects of cochlear compression and frequency selectivity on pitch discrimination of complex tones with unresolved harmonics

    DEFF Research Database (Denmark)

    Bianchi, Federica; Fereczkowski, Michal; Zaar, Johannes

    2015-01-01

    Physiological studies have shown that noise-induced sensorineural hearing loss (SNHL) enhances the amplitude of envelope coding in auditory-nerve fibers. As pitch coding of unresolved complex tones is assumed to rely on temporal envelope coding mechanisms, this study investigated...... for the RP condition. Overall, these findings suggest that both reduced cochlear compression and auditory filter broadening alter the envelope representation of unresolved complex tones, leading to changes in pitch-discrimination performance....... pitchdiscrimination performance in listeners with SNHL. Pitch-discrimination thresholds were obtained in 14 normal-hearing (NH) and 10 hearingimpaired (HI) listeners for sine-phase (SP) and random-phase (RP) unresolved complex tones. The HI listeners performed, on average, similarly as the NH listeners in the SP...

  11. Evaluation of the tripolar electrode stimulation method by numerical analysis and animal experiments for cochlear implants.

    Science.gov (United States)

    Miyoshi, S; Sakajiri, M; Ifukube, T; Matsushima, J

    1997-01-01

    We have proposed the Tripolar Electrode Stimulation Method (TESM) which may enable us to narrow the stimulation region and to move continuously the stimulation site for the cochlear implants. We evaluated whether or not TESM works according to a theory based on numerical analysis using the auditory nerve fiber model. In this simulation, the sum of the excited model fibers were compared with the compound actions potentials obtained from animal experiments. As a result, this experiment showed that TESM could narrow a stimulation region by controlling the sum of the currents emitted from the electrodes on both sides, and continuously move a stimulation site by changing the ratio of the currents emitted from the electrodes on both sides.

  12. Tinnitus after Simultaneous and Sequential Bilateral Cochlear Implantation

    Directory of Open Access Journals (Sweden)

    Geerte G. J. Ramakers

    2017-11-01

    Full Text Available ImportanceThere is an ongoing global discussion on whether or not bilateral cochlear implantation should be standard care for bilateral deafness. Contrary to unilateral cochlear implantation, however, little is known about the effect of bilateral cochlear implantation on tinnitus.ObjectiveTo investigate tinnitus outcomes 1 year after bilateral cochlear implantation. Secondarily, to compare tinnitus outcomes between simultaneous and sequential bilateral cochlear implantation and to investigate long-term follow-up (3 years.Study designThis study is a secondary analysis as part of a multicenter randomized controlled trial.MethodsThirty-eight postlingually deafened adults were included in the original trial, in which the presence of tinnitus was not an inclusion criterion. All participants received cochlear implants (CIs because of profound hearing loss. Nineteen participants received bilateral CIs simultaneously and 19 participants received bilateral CIs sequentially with an inter-implant interval of 2 years. The prevalence and severity of tinnitus before and after simultaneous and sequential bilateral cochlear implantation were measured preoperatively and each year after implantation with the Tinnitus Handicap Inventory (THI and Tinnitus Questionnaire (TQ.ResultsThe prevalence of preoperative tinnitus was 42% (16/38. One year after bilateral implantation, there was a median difference of −8 (inter-quartile range (IQR: −28 to 4 in THI score and −9 (IQR: −17 to −9 in TQ score in the participants with preoperative tinnitus. Induction of tinnitus occurred in five participants, all in the simultaneous group, in the year after bilateral implantation. Although the preoperative and also the postoperative median THI and TQ scores were higher in the simultaneous group, the median difference scores were equal in both groups. In the simultaneous group, tinnitus scores fluctuated in the 3 years after implantation. In the sequential group

  13. A prospective study evaluating cochlear implant management skills: development and validation of the Cochlear Implant Management Skills survey.

    Science.gov (United States)

    Bennett, R J; Jayakody, D M P; Eikelboom, R H; Taljaard, D S; Atlas, M D

    2016-02-01

    To investigate the ability of cochlear implant (CI) recipients to physically handle and care for their hearing implant device(s) and to identify factors that may influence skills. To assess device management skills, a clinical survey was developed and validated on a clinical cohort of CI recipients. Survey development and validation. A prospective convenience cohort design study. Specialist hearing implant clinic. Forty-nine post-lingually deafened, adult CI recipients, at least 12 months postoperative. Survey test-retest reliability, interobserver reliability and responsiveness. Correlations between management skills and participant demographic, audiometric, clinical outcomes and device factors. The Cochlear Implant Management Skills survey was developed, demonstrating high test-retest reliability (0.878), interobserver reliability (0.972) and responsiveness to intervention (skills training) [t(20) = -3.913, P = 0.001]. Cochlear Implant Management Skills survey scores range from 54.69% to 100% (mean: 83.45%, sd: 12.47). No associations were found between handling skills and participant factors. This is the first study to demonstrate a range in cochlear implant device handling skills in CI recipients and offers clinicians and researchers a tool to systematically and objectively identify shortcomings in CI recipients' device handling skills. © 2015 John Wiley & Sons Ltd.

  14. The Human Cochlear Mechanical Nonlinearity Inferred via Psychometric Functions

    Directory of Open Access Journals (Sweden)

    Nizami Lance

    2013-12-01

    Extension of the model of Schairer and colleagues results in credible cochlear nonlinearities in man, suggesting that forward-masking provides a non-invasive way to infer the human mechanical cochlear nonlinearity.

  15. Cytomegalovirus (CMV) Infection Causes Degeneration of Cochlear Vasculature and Hearing Loss in a Mouse Model.

    Science.gov (United States)

    Carraro, Mattia; Almishaal, Ali; Hillas, Elaine; Firpo, Matthew; Park, Albert; Harrison, Robert V

    2017-04-01

    Cytomegalovirus (CMV) infection is one of the most common causes of congenital hearing loss in children. We have used a murine model of CMV infection to reveal functional and structural cochlear pathogenesis. The cerebral cortex of Balb/c mice (Mus musculus) was inoculated with 2000 pfu (plaque forming units) of murine CMV on postnatal day 3. At 6 weeks of age, cochlear function was monitored using auditory brainstem response (ABR) and distortion product otoacoustic emission (DPOAE) measures. Histological assessment of cochlear vasculature using a corrosion cast technique was made at 8 weeks. Vascular casts of mCMV-damaged cochleas, and those of untreated control animals, were examined using scanning electron microscopy. We find very large variations in the degree of vascular damage in animals given identical viral injections (2000 pfu). The primary lesion caused by CMV infection is to the stria vascularis and to the adjacent spiral limbus capillary network. Capillary beds of the spiral ligament are generally less affected. The initial vascular damage is found in the mid-apical turn and appears to progress to more basal cochlear regions. After viral migration to the inner ear, the stria vascularis is the primary affected structure. We suggest that initial auditory threshold losses may relate to the poor development or maintenance of the endocochlear potential caused by strial dysfunction. Our increased understanding of the pathogenesis of CMV-related hearing loss is important for defining methods for early detection and treatment.

  16. Transcanal labyrinthectomy for intractable vertigo after unilateral cochlear implantation.

    Science.gov (United States)

    Heidenreich, Katherine D; Basura, Gregory J; Zwolan, Teresa A; El-Kashlan, Hussam K; Telian, Steven A

    2011-10-01

    Document the use of transcanal labyrinthectomy to treat disabling attacks of vertigo after unilateral cochlear implantation. A 46-year-old woman with severe-profound bilateral sensorineural hearing loss secondary to enlarged vestibular aqueducts underwent cochlear implantation for her right ear with a Nucleus Freedom device. The surgery was uneventful, and postoperative imaging confirmed that the electrode was positioned properly. She developed episodic vertigo 10 to 14 days after the implant surgery, which failed to improve with aggressive vestibular rehabilitation therapy. Plugging of the round window for possible perilymphatic fistula did not relieve her symptoms. Right transcanal labyrinthectomy supplemented by filling the vestibule with gentamicin-soaked Gelfoam and then a customized vestibular rehabilitation program. Comparison of vestibular symptoms and cochlear implant performance before and after transcanal labyrinthectomy. The patient had immediate relief of symptoms, and the function of the cochlear implant was not adversely affected. Transcanal labyrinthectomy may be an effective method to ablate the vestibular end organ after unilateral cochlear implantation. It can offer relief of disabling vertigo without adversely affecting the performance of the implant.

  17. Fourteen-years experience with cochlear implantation in Ramathibodi Hospital.

    Science.gov (United States)

    Kasemsuwan, Lalida; Cheewaruangroj, Wichit; Tungkeeratichai, Jumroon; Bhongmakapat, Thongchai; Thawin, Cheamchit; Lertsukprasert, Krisna; Tiravanitchakul, Rattinan; Dara, Rada; Laothamatas, Jiraporn

    2010-12-01

    To review the cochlear implant program in Ramathibodi Hospital and share experience of cochlear implantation emphasized on clinical and surgical outcomes. Retrospective review of 143 ears (140 patients) operated with cochlear implant between 1995 and 2009. The demographic data including etiology of deafness and findings from temporal bone CTscans were reviewed. The authors' experience with cochlear implant surgery in terms of patient selection, patient advisory clinic, necessary equipment, pre- and postoperative evaluations, surgical techniques and complications were discussed. Most congenital origin was unknown etiology and congenital rubella was the most common known cause. From the CT scans of congenital deafness, vestibular aqueduct dilatation was the most common and found in 29.31% while Mondini malformation was shown to be 16.37%. The authors' surgical technique of using the pocket method and designed bony ridge at cortical mastoid rim had helped stabilizing the implant and electrode fancoil. During the last two years, no complication or revision surgery was detected. Cochlear implant surgery in both children and adults can result in good surgical outcome and fewer complications under experienced surgeons and a good team.

  18. Cochlear injury and adaptive plasticity of the auditory cortex

    Directory of Open Access Journals (Sweden)

    ANNA R. eFETONI

    2015-02-01

    Full Text Available Growing evidence suggests that cochlear stressors as noise exposure and aging can induce homeostatic/maladaptive changes in the central auditory system from the brainstem to the cortex. Studies centered on such changes have revealed several mechanisms that operate in the context of sensory disruption after insult (noise trauma, drug- or age-related injury. The oxidative stress is central to current theories of induced sensory neural hearing loss and aging, and interventions to attenuate the hearing loss are based on antioxidant agent. The present review addresses the recent literature on the alterations in hair cells and spiral ganglion neurons due to noise-induced oxidative stress in the cochlea, as well on the impact of cochlear damage on the auditory cortex neurons. The emerging image emphasizes that noise-induced deafferentation and upward spread of cochlear damage is associated with the altered dendritic architecture of auditory pyramidal neurons. The cortical modifications may be reversed by treatment with antioxidants counteracting the cochlear redox imbalance. These findings open new therapeutic approaches to treat the functional consequences of the cortical reorganization following cochlear damage.

  19. Influence of cochlear implantation on peripheral vestibular receptor function.

    Science.gov (United States)

    Krause, Eike; Louza, Julia P R; Wechtenbruch, Juliane; Gürkov, Robert

    2010-06-01

    The objectives of this study were 1) to assess the influence of a cochlear implantation on peripheral vestibular receptor function in the inner ear in the implant and in the nonimplant side, and 2) to analyze a possible correlation with resulting vertigo symptoms. Prospective clinical study. Cochlear implant center at tertiary referral hospital. A total of 32 patients, aged 15 to 83 years, undergoing cochlear implantation were assessed pre- and postoperatively for caloric horizontal semicircular canal response and vestibular-evoked myogenic potentials of the sacculus, and postoperatively for subjective vertigo symptoms. Patients with vertigo were compared with patients without symptoms with regard to the findings of the vestibular function tests. Cochlear implantation represents a significant risk factor for horizontal semicircular canal impairment (P 0.05). Cochlear implantation is a relevant risk factor for damage of peripheral vestibular receptor function. Therefore, preservation not only of residual hearing function but also of vestibular function should be aimed for, by using minimally invasive surgical techniques. Copyright 2010 American Academy of Otolaryngology-Head and Neck Surgery Foundation. Published by Mosby, Inc. All rights reserved.

  20. Verbal Working Memory in Children With Cochlear Implants

    Science.gov (United States)

    Caldwell-Tarr, Amanda; Low, Keri E.; Lowenstein, Joanna H.

    2017-01-01

    Purpose Verbal working memory in children with cochlear implants and children with normal hearing was examined. Participants Ninety-three fourth graders (47 with normal hearing, 46 with cochlear implants) participated, all of whom were in a longitudinal study and had working memory assessed 2 years earlier. Method A dual-component model of working memory was adopted, and a serial recall task measured storage and processing. Potential predictor variables were phonological awareness, vocabulary knowledge, nonverbal IQ, and several treatment variables. Potential dependent functions were literacy, expressive language, and speech-in-noise recognition. Results Children with cochlear implants showed deficits in storage and processing, similar in size to those at second grade. Predictors of verbal working memory differed across groups: Phonological awareness explained the most variance in children with normal hearing; vocabulary explained the most variance in children with cochlear implants. Treatment variables explained little of the variance. Where potentially dependent functions were concerned, verbal working memory accounted for little variance once the variance explained by other predictors was removed. Conclusions The verbal working memory deficits of children with cochlear implants arise due to signal degradation, which limits their abilities to acquire phonological awareness. That hinders their abilities to store items using a phonological code. PMID:29075747

  1. Cochlear implantation for single-sided deafness and tinnitus suppression.

    Science.gov (United States)

    Holder, Jourdan T; O'Connell, Brendan; Hedley-Williams, Andrea; Wanna, George

    To quantify the potential effectiveness of cochlear implantation for tinnitus suppression in patients with single-sided deafness using the Tinnitus Handicap Inventory. The study included 12 patients with unilateral tinnitus who were undergoing cochlear implantation for single-sided deafness. The Tinnitus Handicap Inventory was administered at the patient's cochlear implant candidacy evaluation appointment prior to implantation and every cochlear implant follow-up appointment, except activation, following implantation. Patient demographics and speech recognition scores were also retrospectively recorded using the electronic medical record. A significant reduction was found when comparing Tinnitus Handicap Inventory score preoperatively (61.2±27.5) to the Tinnitus Handicap Inventory score after three months of cochlear implant use (24.6±28.2, p=0.004) and the Tinnitus Handicap Inventory score beyond 6months of CI use (13.3±18.9, p=0.008). Further, 45% of patients reported total tinnitus suppression. Mean CNC word recognition score improved from 2.9% (SD 9.4) pre-operatively to 40.8% (SD 31.7) by 6months post-activation, which was significantly improved from pre-operative scores (p=0.008). The present data is in agreement with previously published studies that have shown an improvement in tinnitus following cochlear implantation for the large majority of patients with single-sided deafness. Copyright © 2017 Elsevier Inc. All rights reserved.

  2. Schwannoma Originating From the Periphereral Intercostal Nerves

    Directory of Open Access Journals (Sweden)

    Yunus Aksoy

    2017-06-01

    Full Text Available Schwannomas are usually solitary, encapsulated, and asymptomatic, benign neurogenic tumors originating from the nerve sheath. Schwannomas rarely show malignant transformation, however, require close monitoring. They are primarily located in the thorax in the costovertebral sulcus, may rarely originate from peripheral intercostal nerves. Less than 10% of primary thoracic neurogenic tumors originate from the peripheral intercostal nerves. The main treatment and diagnosis of schwannomas are complete surgical resection. We report a rare case of a 40-year-old male with asymptomatic schwannoma originating from an intercostal nerve which was found incidentally on his chest X-ray and was treated with surgery.

  3. Image Registration of Cochlear µCT Data Using Heat Distribution Similarity

    DEFF Research Database (Denmark)

    Kjer, Hans Martin; Vera, Sergio; Fagertun, Jens

    2015-01-01

    Better understanding of the anatomical variability of the human cochlear is important for the design and function of Cochlear Implants. Good non-rigid alignment of high-resolution cochlear μCT data is a challenging task. In this paper we study the use of heat distribution similarity between sampl...

  4. Modelling Cochlear Mechanics

    Directory of Open Access Journals (Sweden)

    Guangjian Ni

    2014-01-01

    Full Text Available The cochlea plays a crucial role in mammal hearing. The basic function of the cochlea is to map sounds of different frequencies onto corresponding characteristic positions on the basilar membrane (BM. Sounds enter the fluid-filled cochlea and cause deflection of the BM due to pressure differences between the cochlear fluid chambers. These deflections travel along the cochlea, increasing in amplitude, until a frequency-dependent characteristic position and then decay away rapidly. The hair cells can detect these deflections and encode them as neural signals. Modelling the mechanics of the cochlea is of help in interpreting experimental observations and also can provide predictions of the results of experiments that cannot currently be performed due to technical limitations. This paper focuses on reviewing the numerical modelling of the mechanical and electrical processes in the cochlea, which include fluid coupling, micromechanics, the cochlear amplifier, nonlinearity, and electrical coupling.

  5. Bilateral cochlear implantation in a patient with bilateral temporal bone fractures.

    Science.gov (United States)

    Chung, Jae Ho; Shin, Myung Chul; Min, Hyun Jung; Park, Chul Won; Lee, Seung Hwan

    2011-01-01

    With the emphasis on bilateral hearing nowadays, bilateral cochlear implantation has been tried out for bilateral aural rehabilitation. Bilateral sensorineural hearing loss caused by head trauma can get help from cochlear implantation. We present the case of a 44-year-old man with bilateral otic capsule violating temporal bone fractures due to head trauma. The patient demonstrated much improved audiometric and psychoacoustic performance after bilateral cochlear implantation. We believe bilateral cochlear implantation in such patient can be a very effective tool for rehabilitation. Copyright © 2011 Elsevier Inc. All rights reserved.

  6. Cochlear nucleus neuron analysis in individuals with presbycusis.

    Science.gov (United States)

    Hinojosa, Raul; Nelson, Erik G

    2011-12-01

    The aim of this study was to analyze the cochlear nucleus neuron population in individuals with normal hearing and presbycusis. Retrospective study of archival human temporal bone and brain stem tissues. Using strict inclusion criteria, the temporal bones and cochlear nuclei from six normal hearing individuals and four individuals with presbycusis were selected for analysis. The spiral ganglion cell population, the cochlear nucleus neuron population, and the cell body size of the neurons were quantified in these cases. A relationship was not observed between age and the spiral ganglion cell population in the normal hearing group. Presbycusis subjects exhibited a reduced spiral ganglion cell population. The mean cochlear nucleus neuron population was observed to be significantly higher in the presbycusis group (mean ± standard deviation: 114,170 ± 10,570) compared to the normal hearing group (91,470 ± 9,510) (P = .019). This difference was predominantly the result of greater multipolar and granule cell neuron populations. Only the fusiform neuron type exhibited a significantly different mean cell body cross-sectional area between the normal hearing group (242 ± 27) and the presbycusis group (300 ± 37) (P = .033). This investigation is the first time, to our knowledge, that the populations of the eight neuron types in the cochlear nucleus have been quantified in both normal hearing individuals and individuals with presbycusis. The data support the concept that presbycusis is not an effect of aging alone but instead may be a condition that predisposes one to hearing loss with advancing age and is characterized by a congenitally elevated cochlear nucleus neuron population. Copyright © 2011 The American Laryngological, Rhinological, and Otological Society, Inc.

  7. Threshold shift: effects of cochlear implantation on the risk of pneumococcal meningitis.

    Science.gov (United States)

    Wei, Benjamin P C; Shepherd, Robert K; Robins-Browne, Roy M; Clark, Graeme M; O'Leary, Stephen J

    2007-04-01

    The study goals were to examine whether cochlear implantation increases the risk of meningitis in the absence of other risk factors and to understand the pathogenesis of pneumococcal meningitis post cochlear implantation. Four weeks following surgery, 54 rats (18 of which received a cochleostomy alone, 18 of which received a cochleostomy and acute cochlear implantation using standard surgical techniques, and 18 of which received a cochlear implant) were infected with Streptococcus pneumoniae via three different routes of bacterial inoculation (middle ear, inner ear, and intraperitoneal) to represent all potential routes of bacterial infection from the upper respiratory tract to the meninges. The presence of a cochlear implant reduced the threshold of bacteria required to cause pneumococcal meningitis from all routes of infection in healthy animals. The presence of a cochlear implant increases the risk of pneumococcal meningitis regardless of the route of bacterial infection. Early detection and treatment of pneumococcal infection such as otitis media may be required, as cochlear implantation may lead to a reduction of infectious threshold for meningitis.

  8. Cochlear Implantation in Patients with Keratitis-Ichthyosis-Deafness Syndrome: A Report of Two Cases

    Directory of Open Access Journals (Sweden)

    Birgul Gumus

    2017-01-01

    Full Text Available Background. Keratitis-ichthyosis-deafness (KID syndrome is a syndrome which presents with hearing loss and visual and keratinization disorders. In such patients, hearing aids cannot be effectively used in the rehabilitation of hearing loss because of the frequent blockage of the external ear canal with epithelial debris and due to dry and tense skin of the external ear canal. Moreover, severe or profound hearing loss also limits the benefits gained from the conventional hearing aids. On the other hand, cochlear implantation is a method that has been used in limited cases in the literature. Case Report. This study presents the results of cochlear implantation applied in our clinic to two children who had been diagnosed with KID. Audiological assessments before and after the cochlear implant operation were performed using pure-tone audiometry, immittance audiometry, and auditory brainstem response (ABR, and the postoperative follow-up was conducted using pure-tone audiometry. Conclusion. Skin problems, visual disturbances, and other additional problems complicate the short-term and long-term rehabilitation after implantation in individuals with KID syndrome. Close monitoring should be exercised due to possible skin complications that may develop during the postoperative period. The families and rehabilitation teams should be warned about the possible visual disturbances and skin complications.

  9. Cochlear neuropathy and the coding of supra-threshold sound.

    Science.gov (United States)

    Bharadwaj, Hari M; Verhulst, Sarah; Shaheen, Luke; Liberman, M Charles; Shinn-Cunningham, Barbara G

    2014-01-01

    Many listeners with hearing thresholds within the clinically normal range nonetheless complain of difficulty hearing in everyday settings and understanding speech in noise. Converging evidence from human and animal studies points to one potential source of such difficulties: differences in the fidelity with which supra-threshold sound is encoded in the early portions of the auditory pathway. Measures of auditory subcortical steady-state responses (SSSRs) in humans and animals support the idea that the temporal precision of the early auditory representation can be poor even when hearing thresholds are normal. In humans with normal hearing thresholds (NHTs), paradigms that require listeners to make use of the detailed spectro-temporal structure of supra-threshold sound, such as selective attention and discrimination of frequency modulation (FM), reveal individual differences that correlate with subcortical temporal coding precision. Animal studies show that noise exposure and aging can cause a loss of a large percentage of auditory nerve fibers (ANFs) without any significant change in measured audiograms. Here, we argue that cochlear neuropathy may reduce encoding precision of supra-threshold sound, and that this manifests both behaviorally and in SSSRs in humans. Furthermore, recent studies suggest that noise-induced neuropathy may be selective for higher-threshold, lower-spontaneous-rate nerve fibers. Based on our hypothesis, we suggest some approaches that may yield particularly sensitive, objective measures of supra-threshold coding deficits that arise due to neuropathy. Finally, we comment on the potential clinical significance of these ideas and identify areas for future investigation.

  10. Cochlear Neuropathy and the Coding of Supra-threshold Sound

    Directory of Open Access Journals (Sweden)

    Hari M Bharadwaj

    2014-02-01

    Full Text Available Many listeners with hearing thresholds within the clinically normal range nonetheless complain of difficulty hearing in everyday settings and understanding speech in noise. Converging evidence from human and animal studies points to one potential source of such difficulties: differences in the fidelity with which supra-threshold sound is encoded in the early portions of the auditory pathway. Measures of auditory subcortical steady-state responses in humans and animals support the idea that the temporal precision of the early auditory representation can be poor even when hearing thresholds are normal. In humans with normal hearing thresholds, behavioral ability in paradigms that require listeners to make use of the detailed spectro-temporal structure of supra-threshold sound, such as selective attention and discrimination of frequency modulation, correlate with subcortical temporal coding precision. Animal studies show that noise exposure and aging can cause a loss of a large percentage of auditory nerve fibers without any significant change in measured audiograms. Here, we argue that cochlear neuropathy may reduce encoding precision of supra-threshold sound, and that this manifests both behaviorally and in subcortical steady-state responses in humans. Furthermore, recent studies suggest that noise-induced neuropathy may be selective for higher-threshold, lower-spontaneous-rate nerve fibers. Based on our hypothesis, we suggest some approaches that may yield particularly sensitive, objective measures of supra-threshold coding deficits that arise due to neuropathy. Finally, we comment on the potential clinical significance of these ideas and identify areas for future investigation.

  11. Scala vestibuli cochlear implantation in patients with partially ossified cochleas.

    Science.gov (United States)

    Berrettini, Stefano; Forli, Francesca; Neri, Emanuele; Segnini, Giovanni; Franceschini, Stefano Sellari

    2002-11-01

    Partial cochlear obstruction is a relatively common finding in candidates for cochlear implants and frequently involves the inferior segment of the scala tympani in the basal turn of the cochlea. In such patients, the scala vestibuli is often patent and offers an alternative site for implantation. The current report describes two patients with such partial obstruction of the inferior segment of the basal cochlear turn, caused in one case by systemic vasculitis (Takayasu's disease) and in the other by obliterative otosclerosis. A scala vestibuli implantation allowed for complete insertion of the electrode array. No problems were encountered during the surgical procedures and the good post-operative hearing and communicative outcomes achieved were similar to those reported in patients without cochlear ossification. The importance of accurate pre-operative radiological study of the inner ear is underscored, to disclose the presence and define the features of the cochlear ossification and ultimately to properly plan the surgical approach.

  12. Production of verb tenses in children with cochlear implants

    Directory of Open Access Journals (Sweden)

    Sokolovac Ivana

    2016-01-01

    Full Text Available The production of verb tenses leads to better language development of children with cochlear implants. The aim of this study was to assess the acquisition of verb tenses in children with cochlear implants. The sample included 60 children, aged from 9 to 15, with average intellectual abilities. The study group consisted of 30 patients with cochlear implants, with no additional disabilities. The control group consisted of 30 subjects with typical speech - language development and preserved hearing. The acquisition of basic tenses was assessed by 'Corpus for the Assessment of the Use of Tenses' (Dimić, 2003. Significant statistical differences were found in the use of the present tense in children with cochlear implants and hearing children (t=-4.385; p<0.001 as well as in the use of the past tense (t=-4.650; p<0.001, and the future tense (t=-4.269; p<0.001. There was also a significant difference in the use of irregular verb 'go' (t=-3.958; p<0.001, as well as in the combination of the present and the past tense (t=-5.806; p<0.001. The present tense was used correctly by most children with cochlear implants (70%, followed by the past tense (53%, and finally the future tense (23%. Children with cochlear implants, even after several years of re/habilitation, do not reach the grammatical development of children with normal hearing.

  13. Hair Barrette Induced Cochlear Implant Receiver Stimulator Site Infection with Extrusion

    Directory of Open Access Journals (Sweden)

    Trung N. Le

    2015-01-01

    Full Text Available Background. Cochlear implant infections and extrusion are uncommon but potentially devastating complications. Recent literature suggests conservative management can be employed. Local measures inclusive of aggressive surgical debridement with vascularized flaps and parenteral antibiotics represent a viable option and often permit device salvage. However, explantation should be considered if there is evidence of systemic, intracranial, or intractable infection. Method. A Case report and literature review. Case Report. This case illustrates a complicated local wound infection associated with cochlear implantation due to transcutaneous adherence of a ferrous hair barrette to a cochlear implant magnet. Reconstruction of computed tomography (CT data with 3D volume rendering significantly improved the value of the images and facilitated patient counseling as well as operative planning. Conclusion. Cochlear implant infections can be associated with foreign bodies. CT images are beneficial in the evaluation of cochlear implant complications. 3D CT images provide a comprehensive view of the site of interest, displaying the relationship of the hardware to the skull and soft tissues, while minimizing associated artifacts. Cochlear implant patients should consider use of nonmetallic hair devices.

  14. Prevalence of inner ear anomalies among cochlear implant candidates.

    Science.gov (United States)

    Aldhafeeri, Ahmad M; Alsanosi, Abdulrahman A

    2016-10-01

    To determine the prevalence of inner ear anomalies and the frequency of different anomaly types among cochlear implant recipients. This study included a retrospective chart review of all patients who received cochlear implants between January 2009 and January 2013 in King Abdulaziz University Hospital cochlear implant program in Riyadh, Saudi Arabia. All subjects underwent thin-cut CT of the temporal bone and MRI. The collected data included age, gender, and CT and MRI findings regarding temporal bone anomalies. Patients with any identified congenital inner ear anomalies were included in the study.  In total, 316 patients' cases were reviewed. Inner ear malformations were identified in 24 patients, which represented a prevalence of 7.5%. Among these 24 patients, 8 (33.3%) presented with a large vestibular aqueduct (LVA), 8 (33.3%) semicircular canal (SCC) dysplasia, 7 (29.1%) classical Mondini deformity, and one (4.1%) cochlear hypoplasia. The prevalence of inner ear anomalies among cochlear implant recipients was 7.5%. This result is consistent with findings worldwide. The most common anomalies were LVA and SCC hypoplasia; by contrast, in other regions, the most common anomaly is either the Mondini deformity, or LVA.

  15. Hyperbaric oxygen upregulates cochlear constitutive nitric oxide synthase

    Directory of Open Access Journals (Sweden)

    Kao Ming-Ching

    2011-02-01

    Full Text Available Abstract Background Hyperbaric oxygen therapy (HBOT is a known adjuvant for treating ischemia-related inner ear diseases. Controversies still exist in the role of HBOT in cochlear diseases. Few studies to date have investigated the cellular changes that occur in inner ears after HBOT. Nitric oxide, which is synthesized by nitric oxide synthase (NOS, is an important signaling molecule in cochlear physiology and pathology. Here we investigated the effects of hyperbaric oxygen on eardrum morphology, cochlear function and expression of NOS isoforms in cochlear substructures after repetitive HBOT in guinea pigs. Results Minor changes in the eardrum were observed after repetitive HBOT, which did not result in a significant hearing threshold shift by tone burst auditory brainstem responses. A differential effect of HBOT on the expression of NOS isoforms was identified. Upregulation of constitutive NOS (nNOS and eNOS was found in the substructures of the cochlea after HBOT, but inducible NOS was not found in normal or HBOT animals, as shown by immunohistochemistry. There was no obvious DNA fragmentation present in this HBOT animal model. Conclusions The present evidence indicates that the customary HBOT protocol may increase constitutive NOS expression but such upregulation did not cause cell death in the treated cochlea. The cochlear morphology and auditory function are consequently not changed through the protocol.

  16. Exploring the experiences of teenagers with cochlear implants.

    Science.gov (United States)

    Watson, Victoria; Verschuur, Carl; Lathlean, Judith

    2016-11-01

    Teenage cochlear implant users' perceptions of deafness, surgery, fitting of the device and life as a cochlear implant wearer were explored in order to gain a more comprehensive understanding of teenagers' experiences of living with the device. Semi-structured in-depth interviews were undertaken and analysed using thematic analysis. Ten teenagers aged 14-16 years with at least one cochlear implant were interviewed. Seven teenagers experienced great pre-operative anxiety and two reported significant post-operative pain. Four of the teenagers described a mismatch between their expectations and the disappointing reality of adjusting to the device. However, all the teenagers reported an enhanced sense of well-being as a result of being able to interact more easily with their world around them. The teenagers differed in the extent to which they identified with the hearing and deaf world. Despite the early challenges, over time the teenagers experienced many functional and psychosocial benefits. Most felt their lives were now easier as a result of the cochlear implant(s). They described complex, flexible identities. By giving prominence to the teenagers' voices this study has added new knowledge concerning their experience of surgery. The findings also more fully revealed the challenges of adjusting to the device and the impact of having a cochlear implant on the teenagers' identities. Clinical recommendations are made to address the gaps in service highlighted by these findings.

  17. Label-free photoacoustic microscopy of peripheral nerves

    Science.gov (United States)

    Matthews, Thomas Paul; Zhang, Chi; Yao, Da-Kang; Maslov, Konstantin; Wang, Lihong V.

    2014-01-01

    Peripheral neuropathy is a common neurological problem that affects millions of people worldwide. Diagnosis and treatment of this condition are often hindered by the difficulties in making objective, noninvasive measurements of nerve fibers. Photoacoustic microscopy (PAM) has the ability to obtain high resolution, specific images of peripheral nerves without exogenous contrast. We demonstrated the first proof-of-concept imaging of peripheral nerves using PAM. As validated by both standard histology and photoacoustic spectroscopy, the origin of photoacoustic signals is myelin, the primary source of lipids in the nerves. An extracted sciatic nerve sandwiched between two layers of chicken tissue was imaged by PAM to mimic the in vivo case. Ordered fibrous structures inside the nerve, caused by the bundles of myelin-coated axons, could be observed clearly. With further technical improvements, PAM can potentially be applied to monitor and diagnose peripheral neuropathies.

  18. Verbal Working Memory in Children with Cochlear Implants

    Science.gov (United States)

    Nittrouer, Susan; Caldwell-Tarr, Amanda; Low, Keri E.; Lowenstein, Joanna H.

    2017-01-01

    Purpose: Verbal working memory in children with cochlear implants and children with normal hearing was examined. Participants: Ninety-three fourth graders (47 with normal hearing, 46 with cochlear implants) participated, all of whom were in a longitudinal study and had working memory assessed 2 years earlier. Method: A dual-component model of…

  19. Modeling auditory-nerve responses to electrical stimulation

    DEFF Research Database (Denmark)

    Joshi, Suyash Narendra; Dau, Torsten; Epp, Bastian

    2014-01-01

    μs, which is large enough to affect the temporal coding of sounds and hence, potentially, the communication abilities of the CI listener. In the present study, two recently proposed models of electric stimulation of the AN [1,2] were considered in terms of their efficacy to predict the spike timing...... for anodic and cathodic stimulation of the AN of cat [3]. The models’ responses to the electrical pulses of various shapes [4,5,6] were also analyzed. It was found that, while the models can account for the firing rates in response to various biphasic pulse shapes, they fail to correctly describe the timing......Cochlear implants (CI) directly stimulate the auditory nerve (AN), bypassing the mechano-electrical transduction in the inner ear. Trains of biphasic, charge balanced pulses (anodic and cathodic) are used as stimuli to avoid damage of the tissue. The pulses of either polarity are capable...

  20. Working memory in Farsi-speaking children with normal development and cochlear implant.

    Science.gov (United States)

    Soleymani, Zahra; Amidfar, Meysam; Dadgar, Hooshang; Jalaie, Shohre

    2014-04-01

    Working memory has an important role in language acquisition and development of cognition skills. The ability of encoding, storage and retrieval of phonological codes, as activities of working memory, acquired by audition sense. Children with cochlear implant experience a period that they are not able to perceive sounds. In order to assess the effect of hearing on working memory, we investigated working memory as a cognition skill in children with normal development and cochlear implant. Fifty students with normal hearing and 50 students with cochlear implant aged 5-7 years participated in this study. Children educated in the preschool, the first and second grades. Children with normal development were matched based on age, gender, and grade of education with cochlear implant. Two components of working memory including phonological loop and central executive were compared between two groups. Phonological loop assessed by nonword repetition task and forward digit span. To assess central executive component backward digit span was used. The developmental trend was studied in children with normal development and cochlear implant as well. The effect of age at implantation in children with cochlear implants on components of working memory was investigated. There are significant differences between children with normal development and cochlear implant in all tasks that assess working memory (p memory between different grades showed significant differences both in children with normal development and in children with cochlear implant (p implied that children with cochlear implant may experience difficulties in working memory. Therefore, these children have problems in encoding, practicing, and repeating phonological units. The results also suggested working memory develops when the child grows up. In cochlear implant children, with decreasing age at implantation and increasing their experience in perceiving sound, working memory skills improved. Copyright © 2014 Elsevier

  1. Patient-specific estimation of detailed cochlear shape from clinical CT images

    DEFF Research Database (Denmark)

    Kjer, H Martin; Fagertun, Jens; Wimmer, Wilhelm

    2018-01-01

    of the detailed patient-specific cochlear shape from CT images. From a collection of temporal bone [Formula: see text]CT images, we build a cochlear statistical deformation model (SDM), which is a description of how a human cochlea deforms to represent the observed anatomical variability. The model is used...... for regularization of a non-rigid image registration procedure between a patient CT scan and a [Formula: see text]CT image, allowing us to estimate the detailed patient-specific cochlear shape. We test the accuracy and precision of the predicted cochlear shape using both [Formula: see text]CT and CT images...

  2. [Threefold intraoperative electrophysiological monitoring of vestibular neurectomy].

    Science.gov (United States)

    Hausler, R; Kasper, A

    1991-01-01

    A threefold intraoperative monitoring of facial nerve, auditory nerve and vestibular nerve function was performed in 14 cases of retrosigmoidal neurectomy. The facial nerve was monitoring with a pressure transducer placed against the cheek (Opalarm system). The auditory nerve was monitored with acoustically (click) evoked early potentials and the vestibular nerve was monitored with electrically evoked vestibular potentials obtained by direct stimulation (biphasic current pulses of 0.75-mA p-p, 100 us, 20/s) of the exposed vestibular nerve in the cerebellopontine angle before, during and after neurectomy. A characteristic vertex negative peak having a latency of approximately 2 ms and approximately 0.5 uV amplitude was obtained between a forehead and an ipsilateral ear lobe electrode (2 x 1,000 averaged responses over 10 ms) before the neurectomy. This response disappeared after selective vestibular nerve section proximal to the stimulation site. A diminished response amplitude was measured after incomplete nerve section. Simultaneous acoustic masking had no influence on the vestibular potential. The 14 operated patients became all free of vertiginous spells and drop-attacks except one patient who developed a contralateral Menière's. Facial nerve function remained normal in all. Hearing preservation was obtained in 12 patients (86%). The threefold intraoperative monitoring has turned out to be an additional safety factor for facial and auditory nerve preservation and, thanks to the recording of vestibular potentials, it increased the efficiency of vestibular neurectomy.

  3. Challenges in Improving Cochlear Implant Performance and Accessibility.

    Science.gov (United States)

    Zeng, Fan-Gang

    2017-08-01

    Here I identify two gaps in cochlear implants that have been limiting their performance and acceptance. First, cochlear implant performance has remained largely unchanged, despite the number of publications tripling per decade in the last 30 years. Little has been done so far to address a fundamental limitation in the electrode-to-neuron interface, with the electrode size being a thousand times larger than the neuron diameter while the number of electrodes being a thousand times less. Both the small number and the large size of electrodes produce broad spatial activation and poor frequency resolution that limit current cochlear implant performance. Second, a similarly rapid growth in cochlear implant volume has not produced an expected decrease in unit price in the same period. The high cost contributes to low market penetration rate, which is about 20% in developed countries and less than 1% in developing countries. I will discuss changes needed in both research strategy and business practice to close the gap between prosthetic and normal hearing as well as that between haves and have-nots.

  4. Cochlear implantation in Waardenburg syndrome: The Indian scenario.

    Science.gov (United States)

    Deka, Ramesh Chandra; Sikka, Kapil; Chaturvedy, Gaurav; Singh, Chirom Amit; Venkat Karthikeyan, C; Kumar, Rakesh; Agarwal, Shivani

    2010-10-01

    Children with Waardenburg syndrome (WS) exhibiting normal inner ear anatomy, like those included in our cohort, derive significant benefit from cochlear implantation and results are comparable to those reported for the general population of implanted children. The patient population of WS accounts for approximately 2% of congenitally deaf children. The purpose of this retrospective case review was to describe the outcomes for those children with WS who have undergone cochlear implantation. On retrospective chart review, there were four cases with WS who underwent cochlear implantation. These cases were assessed for age at implantation, clinical and radiological features, operative and perioperative course, and performance outcomes. Auditory perception and speech production ability were evaluated using categories of auditory performance (CAP), meaningful auditory integration scales (MAIS), and speech intelligibility rating (SIR) during the follow-up period. In this group of children with WS, with a minimum follow-up of 12 months, the CAP score ranged from 3 to 5, MAIS from 25 to 30, and SIR was 3. These scores are comparable with those of other cochlear implantees.

  5. Pneumococcal meningitis post-cochlear implantation: preventative measures.

    Science.gov (United States)

    Wei, Benjamin P C; Shepherd, Robert K; Robins-Browne, Roy M; Clark, Graeme M; O'Leary, Stephen J

    2010-11-01

    Both clinical data and laboratory studies demonstrated the risk of pneumococcal meningitis post-cochlear implantation. This review examines strategies to prevent post-implant meningitis. Medline/PubMed database; English articles after 1980. Search terms: cochlear implants, pneumococcus meningitis, streptococcus pneumonia, immunization, prevention. Narrative review. All articles relating to post-implant meningitis without any restriction in study designs were assessed and information extracted. The presence of inner ear trauma as a result of surgical technique or cochlear implant electrode array design was associated with a higher risk of post-implant meningitis. Laboratory data demonstrated the effectiveness of pneumococcal vaccination in preventing meningitis induced via the hematogenous route of infection. Fibrous sealing around the electrode array at the cochleostomy site, and the use of antibiotic-coated electrode array reduced the risk of meningitis induced via an otogenic route. The recent scientific data support the U.S. Food and Drug Administration recommendation of pneumococcal vaccination for the prevention of meningitis in implant recipients. Nontraumatic cochlear implant design, surgical technique, and an adequate fibrous seal around the cochleostomy site further reduce the risk of meningitis. Copyright © 2010 American Academy of Otolaryngology–Head and Neck Surgery Foundation. Published by Mosby, Inc. All rights reserved.

  6. Multichannel cochlear implantation in the scala vestibuli.

    Science.gov (United States)

    Lin, Karen; Marrinan, Michelle S; Waltzman, Susan B; Roland, J Thomas

    2006-08-01

    Sensorineural hearing loss resulting from otosclerosis, meningitis, chronic otitis media, autoimmune ear disease, and trauma can be associated with partial or total obstruction of the cochlear scalae. Multichannel cochlear implantation may be difficult in a cochlea with an obstructed scala tympani. The purpose of this study is to determine the safety and efficacy of scala tympani electrode insertion. Retrospective chart review. Academic medical center. Eight children and adults with profound sensorineural hearing loss who underwent cochlear implantation with known scala vestibuli electrode array insertion were subjects for this study. Eight study subjects underwent implantation: five with the Nucleus 24RCS (Contour) device and three with the Nucleus 24M device. Imaging findings, operative findings, and age-appropriate speech perception testing. All patients had full electrode insertion. Various obstructive patterns on computed tomography and magnetic resonance imaging were found, and there was a range of speech perception results. All but one patient improved based on age-appropriate monosyllabic word and sentence tests. Scala vestibuli multielectrode insertion is a viable alternative when scala tympani insertion is not possible because of abnormal anatomy or anatomical changes secondary to disease or previous implantation. We will also present an algorithm of options for decision making for implantation when encountering cochlear obstruction and difficult electrode insertion.

  7. Cochlear Implants and Psychiatric Assessments: a Norrie Disease Case Report.

    Science.gov (United States)

    Jacques, Denis; Dubois, Thomas; Zdanowicz, Nicolas; Gilain, Chantal; Garin, Pierre

    2017-09-01

    It is important to perform psychiatric assessments of adult patients who are candidates for cochlear implants both to screen them for psychiatric disorders and to assess their understanding and compliance with the procedure. Deafness is a factor of difficulty for conducting in-depth psychiatric interviews, but concomitant blindness may make it impossible. After a description of Norrie disease, a rare disease in which blindness and deafness may occur together, we propose a case report of a patient suffering from the disease and who consulted in view of a cochlear implant. Early information on cochlear implants appears to be necessary before total deafness occurs in patients suffering from Norrie disease. An inventory of digital communication tools that can be used by the patient is also highly valuable. Research should be supported for a more systematic use of psychiatric assessments prior to cochlear implants. In the special case of Norrie disease, we recommend early screening for mental retardation and related psychotic disorders and, depending on the patient's level of understanding, preventive information on the benefits and limits of cochlear implants before total deafness occurs.

  8. Comparisons between detection threshold and loudness perception for individual cochlear implant channels

    Science.gov (United States)

    Bierer, Julie Arenberg; Nye, Amberly D

    2014-01-01

    Objective The objective of the present study, performed in cochlear implant listeners, was to examine how the level of current required to detect single-channel electrical pulse trains relates to loudness perception on the same channel. The working hypothesis was that channels with relatively high thresholds, when measured with a focused current pattern, interface poorly to the auditory nerve. For such channels a smaller dynamic range between perceptual threshold and the most comfortable loudness would result, in part, from a greater sensitivity to changes in electrical field spread compared to low-threshold channels. The narrower range of comfortable listening levels may have important implications for speech perception. Design Data were collected from eight, adult cochlear implant listeners implanted with the HiRes90k cochlear implant (Advanced Bionics Corp.). The partial tripolar (pTP) electrode configuration, consisting of one intracochlear active electrode, two flanking electrodes carrying a fraction (σ) of the return current, and an extracochlear ground, was used for stimulation. Single-channel detection thresholds and most comfortable listening levels were acquired using the most focused pTP configuration possible (σ ≥ 0.8) to identify three channels for further testing – those with the highest, median, and lowest thresholds – for each subject. Threshold, equal-loudness contours (at 50% of the monopolar dynamic range), and loudness growth functions were measured for each of these three test channels using various partial tripolar fractions. Results For all test channels, thresholds increased as the electrode configuration became more focused. The rate of increase with the focusing parameter σ was greatest for the high-threshold channel compared to the median- and low-threshold channels. The 50% equal-loudness contours exhibited similar rates of increase in level across test channels and subjects. Additionally, test channels with the highest

  9. Costs involved in using a cochlear implant in South Africa

    Directory of Open Access Journals (Sweden)

    Gillian Robyn Kerr

    2012-12-01

    Full Text Available Cochlear implantation is an expensive but effective lifelong intervention for individuals with a severe-to-profound hearing loss. The primary aim of this study was to survey the short- and long-term costs of cochlear implantation. Individuals (N=154 using cochlear implants obtained from the University of Stellenbosch-Tygerberg Hospital Cochlear Implant Unit in Cape Town, South Africa were surveyed using a questionnaire and patient record review. The questionnaire used a combination of closed and open-ended questions to gather both quantitative and qualitative information. Costs were categorised as short- and long-term costs. All costs were converted to constant rands (June 2010 using the Consumer Price Index to allow for comparison in real terms over time. In the first 10 years of implantation the average estimated costs incurred by adults totalled R379 626, and by children R455 225. The initial purchase of the implant system was the most substantial cost, followed by upgrading of the processor. Travel and accommodation costs peaked in the first 2 years. On average the participants spent R2 550 per year on batteries and spares. Rehabilitation for children cost an average of R7 200. Insurance costs averaged R4 040 per year, and processor repairs R3 000 each. In addition to the upfront expense of obtaining the cochlear implant system, individuals using a cochlear implant in South Africa should be prepared for the long-term costs of maintenance, accessing the unit, support services and additional costs associated with use. Knowledge of these costs is important to ensure that individuals are successful users of their cochlear implants in the long term.

  10. Waveform efficiency analysis of auditory nerve fiber stimulation for cochlear implants

    International Nuclear Information System (INIS)

    Navaii, Mehdi Lotfi; Sadhedi, Hamed; Jalali, Mohsen

    2013-01-01

    Evaluation of the electrical stimulation efficiency of various stimulating waveforms is an important issue for efficient neural stimulator design. Concerning the implantable micro devices design, it is also necessary to consider the feasibility of hardware implementation of the desired waveforms. In this paper, the charge, power and energy efficiency of four waveforms (i.e. square, rising ramp, triangular and rising ramp-decaying exponential) in various durations have been simulated and evaluated based on the computational model of the auditory nerve fibers. Moreover, for a fair comparison of their feasibility, a fully integrated current generator circuit has been developed so that the desired stimulating waveforms can be generated. The simulation results show that stimulation with the square waveforms is a proper choice in short and intermediate durations while the rising ramp-decaying exponential or triangular waveforms can be employed for long durations.

  11. Is cochlear implantation a good treatment method for profoundly deafened elderly?

    Directory of Open Access Journals (Sweden)

    Lachowska M

    2013-10-01

    Full Text Available Magdalena Lachowska, Agnieszka Pastuszka, Paulina Glinka, Kazimierz Niemczyk Department of Otolaryngology, Hearing Implant Center, Medical University of Warsaw, Warsaw, Poland Purpose: To assess the benefits of cochlear implantation in the elderly. Patients and methods: A retrospective analysis of 31 postlingually deafened elderly (≥60 years of age with unilateral cochlear implants was conducted. Audiological testing included preoperative and postoperative pure-tone audiometry and a monosyllabic word recognition test presented from recorded material in free field. Speech perception tests included Ling's six sound test (sound detection, discrimination, and identification, syllable discrimination, and monosyllabic and multisyllabic word recognition (open set without lip-reading. Everyday life benefits from cochlear implantation were also evaluated. Results: The mean age at the time of cochlear implantation was 72.4 years old. The mean post-implantation follow-up time was 2.34 years. All patients significantly improved their audiological and speech understanding performances. The preoperative mean pure-tone average threshold for 500 Hz, 1,000 Hz, 2,000 Hz, and 4,000 Hz was 110.17 dB HL. Before cochlear implantation, all patients scored 0% on the monosyllabic word recognition test in free field at 70 dB SPL intensity level. The postoperative pure-tone average was 37.14 dB HL (the best mean threshold was 17.50 dB HL, the worst was 58.75 dB HL. After the surgery, mean monosyllabic word recognition reached 47.25%. Speech perception tests showed statistically significant improvement in speech recognition. Conclusion: The results of this study showed that cochlear implantation is indeed a successful treatment for improving speech recognition and offers a great help in everyday life to deafened elderly patients. Therefore, they can be good candidates for cochlear implantation and their age alone should not be a relevant or excluding factor when choosing

  12. Auditory system physiology (CNS) : behavioral studies psychoacoustics

    CERN Document Server

    Neff, William

    1975-01-01

    nerve; subsequently, however, they concluded that the recordings had been from aberrant cells of the cochlear nucleus lying central to the glial margin of the VIII nerve (GALAMBOS and DAVIS, 1948). The first successful recordmgs from fibres of the cochlear nerve were made by TASAKI (1954) in the guinea pig. These classical but necessarily limited results were greatly extended by ROSE, GALAMBOS, and HUGHES (1959) in the cat cochlear nucleus and by KATSUKI and co-workers (KATSUKI et at. , 1958, 1961, 1962) in the cat and monkey cochlear nerve. Perhaps the most significant developments have been the introduction of techniques for precise control of the acoustic stimulus and the quantitative analysis of neuronal response patterns, notably by the laboratories of KIANG (e. g. GERSTEIN and KIANG, 1960; KIANG et at. , 1962b, 1965a, 1967) and ROSE (e. g. ROSE et at. , 1967; HIND et at. , 1967). These developments have made possible a large number of quanti­ tative investigations of the behaviour of representative num...

  13. The long-term concerns post cochlear implantation as experienced ...

    African Journals Online (AJOL)

    Background. Cochlear implantation aims to provide an effective means of spoken communication for prelingually deaf children. However, studies in this field are mostly clinically orientated, with little focus on the experiences and long-term concerns of families post cochlear implantation (CI). Objective. To describe the ...

  14. A software tool for analyzing multichannel cochlear implant signals.

    Science.gov (United States)

    Lai, Wai Kong; Bögli, Hans; Dillier, Norbert

    2003-10-01

    A useful and convenient means to analyze the radio frequency (RF) signals being sent by a speech processor to a cochlear implant would be to actually capture and display them with appropriate software. This is particularly useful for development or diagnostic purposes. sCILab (Swiss Cochlear Implant Laboratory) is such a PC-based software tool intended for the Nucleus family of Multichannel Cochlear Implants. Its graphical user interface provides a convenient and intuitive means for visualizing and analyzing the signals encoding speech information. Both numerical and graphic displays are available for detailed examination of the captured CI signals, as well as an acoustic simulation of these CI signals. sCILab has been used in the design and verification of new speech coding strategies, and has also been applied as an analytical tool in studies of how different parameter settings of existing speech coding strategies affect speech perception. As a diagnostic tool, it is also useful for troubleshooting problems with the external equipment of the cochlear implant systems.

  15. Libyan cochlear implant programme: achievements, difficulties, and future goals

    Directory of Open Access Journals (Sweden)

    Samya El-Ogbi

    2011-05-01

    Full Text Available Cochlear implantation has become established worldwide as a safe and effective method of auditory rehabilitation of selected severely and profound deaf children and adults. Over 100,000 patients have received cochlear implants worldwide with the paediatric population proving to be the main beneficiaries. The Libyan cochlear implant programme was set up in 2004. Data relating to the patients who received cochlear implantation at Tripoli Medical Centre between October 2007 and February 2010 were analysed. Implant operations were performed on 37 patients. All patients received Med-El SONATATI 100 devices. Thirty-four (91.9% of these patients were children, whilst three (8.1% were adults. Combined, congenital hearing loss (56.8% and perinatal/neonatal (29.7% were the two main aetiological factors in children. Seventeen patients (45.9% had a positive family history of deafness. Sixteen patients (43.2% were born to blood-related parents. The overall rate of minor and major complications was 16.2%, which is comparable to previous studies.

  16. Libyan cochlear implant programme: achievements, difficulties, and future goals.

    Science.gov (United States)

    Salamat, Ali; Esriti, Anwer; Ehtuish, Asia; El-Ogbi, Samya

    2011-01-01

    Cochlear implantation has become established worldwide as a safe and effective method of auditory rehabilitation of selected severely and profound deaf children and adults. Over 100,000 patients have received cochlear implants worldwide with the paediatric population proving to be the main beneficiaries. The Libyan cochlear implant programme was set up in 2004. Data relating to the patients who received cochlear implantation at Tripoli Medical Centre between October 2007 and February 2010 were analysed. Implant operations were performed on 37 patients. All patients received Med-El SONATA(TI) (100) devices. Thirty-four (91.9%) of these patients were children, whilst three (8.1%) were adults. Combined, congenital hearing loss (56.8%) and perinatal/neonatal (29.7%) were the two main aetiological factors in children. Seventeen patients (45.9%) had a positive family history of deafness. Sixteen patients (43.2%) were born to blood-related parents. The overall rate of minor and major complications was 16.2%, which is comparable to previous studies.

  17. Phrenic nerve stimulation during neck dissection for advanced thyroid cancer involving level IV: is it worth doing it?

    Science.gov (United States)

    Duque, Carlos S; Dueñas, Juan P; Marulanda, Marcela; Pérez, Diana; Londoňo, Andres; Roy, Soham; Khadem, Mai Al

    2017-03-01

    During thyroidectomy and neck dissection surgery for advanced or recurrent metastatic thyroid cancer under intraoperative monitoring, we used the available technology to assess the feasibility of such an intervention to monitor those patients with phrenic nerves at risk. A retrospective review of patients operated on from January 2009 to December 2015 by a single surgeon (CSD) was conducted. Patients who had neck and mediastinal dissection, with or without total thyroidectomy, due to advanced or recurrent metastatic disease to the neck were selected. The procedures were done under intraoperative nerve monitoring using nerve monitoring systems (NIM 2.0 or 3.0; Medtronic, Jacksonville, FL, USA). A total of 19 patients were included in the study, with a mean age of 57.6 years ± 16.3 and a male/female ratio of 10:9. Overall, all patients had an intact phrenic nerve at the conclusion of the surgery. One patient had an aggressive tumor that precluded sacrifice of the left recurrent laryngeal nerve and ipsilateral thoracic duct. The procedure was complicated by a temporary impairment of the diaphragm contraction with intraoperative nerve monitoring as well as a chyle fistula. This was due to the manipulation of the tissue surrounding the phrenic nerve. Intraoperative nerve monitoring of the phrenic nerve offers the surgeon a "potential" method of ensuring phrenic nerve integrity in cases of advanced thyroid cancers with gross level IV metastatic disease. Further prospective studies are needed to assess the risks of this intervention and evaluate the method of recording diaphragm contraction movement.

  18. Microphone directionality, pre-emphasis filter, and wind noise in cochlear implants.

    Science.gov (United States)

    Chung, King; McKibben, Nicholas

    2011-10-01

    Wind noise can be a nuisance or a debilitating masker for cochlear implant users in outdoor environments. Previous studies indicated that wind noise at the microphone/hearing aid output had high levels of low-frequency energy and the amount of noise generated is related to the microphone directionality. Currently, cochlear implants only offer either directional microphones or omnidirectional microphones for users at-large. As all cochlear implants utilize pre-emphasis filters to reduce low-frequency energy before the signal is encoded, effective wind noise reduction algorithms for hearing aids might not be applicable for cochlear implants. The purposes of this study were to investigate the effect of microphone directionality on speech recognition and perceived sound quality of cochlear implant users in wind noise and to derive effective wind noise reduction strategies for cochlear implants. A repeated-measure design was used to examine the effects of spectral and temporal masking created by wind noise recorded through directional and omnidirectional microphones and the effects of pre-emphasis filters on cochlear implant performance. A digital hearing aid was programmed to have linear amplification and relatively flat in-situ frequency responses for the directional and omnidirectional modes. The hearing aid output was then recorded from 0 to 360° at flow velocities of 4.5 and 13.5 m/sec in a quiet wind tunnel. Sixteen postlingually deafened adult cochlear implant listeners who reported to be able to communicate on the phone with friends and family without text messages participated in the study. Cochlear implant users listened to speech in wind noise recorded at locations that the directional and omnidirectional microphones yielded the lowest noise levels. Cochlear implant listeners repeated the sentences and rated the sound quality of the testing materials. Spectral and temporal characteristics of flow noise, as well as speech and/or noise characteristics before

  19. Normal and sonographic anatomy of selected peripheral nerves. Part II: Peripheral nerves of the upper limb

    Directory of Open Access Journals (Sweden)

    Berta Kowalska

    2012-06-01

    Full Text Available The ultrasonographic examination is frequently used for imaging peripheral nerves. It serves to supplement the physical examination, electromyography, and magnetic resonance imaging. As in the case of other USG imaging studies, the examination of peripheral nerves is non-invasive, well-tolerated by patients, and relatively inexpensive. Part I of this article series described in detail the characteristic USG picture of peripheral nerves and the proper examination technique, following the example of the median nerve. This nerve is among the most often examined peripheral nerves of the upper limb. This part presents describes the normal anatomy and ultrasound picture of the remaining large nerve branches in the upper extremity and neck – the spinal accessory nerve, the brachial plexus, the suprascapular, axillary, musculocutaneous, radial and ulnar nerves. Their normal anatomy and ultrasonographic appearance have been described, including the division into individual branches. For each of them, specific reference points have been presented, to facilitate the location of the set trunk and its further monitoring. Sites for the application of the ultrasonographic probe at each reference point have been indicated. In the case of the ulnar nerve, the dynamic component of the examination was emphasized. The text is illustrated with images of probe positioning, diagrams of the normal course of the nerves as well as a series of ultrasonographic pictures of normal nerves of the upper limb. This article aims to serve as a guide in the ultrasound examination of the peripheral nerves of the upper extremity. It should be remembered that a thorough knowledge of the area’s topographic anatomy is required for this type of examination.

  20. Cochlear implantation in autistic children with profound sensorineural hearing loss.

    Science.gov (United States)

    Lachowska, Magdalena; Pastuszka, Agnieszka; Łukaszewicz-Moszyńska, Zuzanna; Mikołajewska, Lidia; Niemczyk, Kazimierz

    2016-11-19

    Cochlear implants have become the method of choice for the treatment of severe-to-profound hearing loss in both children and adults. Its benefits are well documented in the pediatric and adult population. Also deaf children with additional needs, including autism, have been covered by this treatment. The aim of this study was to assess the benefits from cochlear implantation in deafened children with autism as the only additional disability. This study analyzes data of six children. The follow-up time was at least 43 months. The following data were analyzed: medical history, reaction to music and sound, Ling's six sounds test, onomatopoeic word test, reaction to spoken child's name, response to requests, questionnaire given to parents, sound processor fitting sessions and data. After cochlear implantation each child presented other communication skills. In some children, the symptoms of speech understanding were observed. No increased hyperactivity associated with daily use cochlear implant was observed. The study showed that in autistic children the perception is very important for a child's sense of security and makes contact with parents easier. Our study showed that oral communication is not likely to be a realistic goal in children with cochlear implants and autism. The implantation results showed benefits that varied among those children. The traditional methods of evaluating the results of cochlear implantation in children with autism are usually insufficient to fully assess the functional benefits. These benefits should be assessed in a more comprehensive manner taking into account the limitations of communication resulting from the essence of autism. It is important that we share knowledge about these complex children with cochlear implants. Copyright © 2016 Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial. Published by Elsevier Editora Ltda. All rights reserved.

  1. Conductive component after cochlear implantation in patients with residual hearing conservation.

    Science.gov (United States)

    Chole, Richard A; Hullar, Timothy E; Potts, Lisa G

    2014-12-01

    Changes in auditory thresholds following cochlear implantation are generally assumed to be due to damage to neural elements. Theoretical studies have suggested that placement of a cochlear implant can cause a conductive hearing loss. Identification of a conductive component following cochlear implantation could guide improvements in surgical techniques or device designs. The purpose of this study is to characterize new-onset conductive hearing losses after cochlear implantation. In a prospective study, air- and bone-conduction audiometric testing were completed on cochlear implant recipients. An air-bone gap equal to or greater than 15 dB HL at 2 frequencies determined the presence of a conductive component. Of the 32 patients with preoperative bone-conduction hearing, 4 patients had a new-onset conductive component resulting in a mixed hearing loss, with air-conduction thresholds ranging from moderate to profound and an average air-bone gap of 30 dB HL. One had been implanted through the round window, 2 had an extended round window, and 1 had a separate cochleostomy. Loss of residual hearing following cochlear implantation may be due in part to a conductive component. Identifying the mechanism for this conductive component may help minimize hearing loss. Postoperative hearing evaluation should measure both air- and bone-conduction thresholds.

  2. Cochlear Implantation in Siblings With Refsum's Disease.

    Science.gov (United States)

    Stähr, Kerstin; Kuechler, Alma; Gencik, Martin; Arnolds, Judith; Dendy, Meaghan; Lang, Stephan; Arweiler-Harbeck, Diana

    2017-08-01

    Whether the origin of severe hearing loss in Refsum's syndrome is caused by cochlear impairment or retrocochlear degeneration remains unclear. This case report aims to investigate hearing performance before and after cochlear implantation to shed light on this question. Also, identification of new mutations causing Refsum's syndrome would be helpful in generating additional means of diagnosis. A family of 4 individuals was subjected to genetic testing. Two siblings (56 and 61 years old) suffered from severe hearing and vision loss and received bilateral cochlear implants. Genetic analysis, audiological outcome, and clinical examinations were performed. One new mutation in the PHYH gene (c.768del63bp) causing Refsum's disease was found. Preoperative distortion product otoacoustic emissions (DPAOEs) were absent. Postoperative speech perception in Freiburger speech test was 100% for bisyllabic words and 85% (patient No. 1) and 65% (patient No. 2), respectively, for monosyllabic words. Five years after implantation, speech perception remained stable for bisyllabic words but showed decreasing capabilities for monosyllabic words. A new mutation causing Refsum's disease is presented. Cochlear implantation in case of severe hearing loss leads to an improvement in speech perception and should be recommended for patients with Refsum's disease, especially when the hearing loss is combined with a severe loss of vision. Decrease of speech perception in the long-term follow-up could indicate an additional retrocochlear degeneration.

  3. Are parents of children with cochlear implants coping?: research ...

    African Journals Online (AJOL)

    Many variables must be considered during the evaluation and rehabilitation of children for cochlear implantation, one of which is parental influence (for the duration of this report the parents, caregivers and guardians of children with cochlear implants and / or hearing impairments will be referred to as 'parents'). The aim of ...

  4. Stronger efferent suppression of cochlear neural potentials by contralateral acoustic stimulation in awake than in anesthetized chinchilla

    Directory of Open Access Journals (Sweden)

    Cristian eAedo

    2015-03-01

    Full Text Available There are two types of sensory cells in the mammalian cochlea, inner hair cells, which make synaptic contact with auditory-nerve afferent fibers, and outer hair cells that are innervated by crossed and uncrossed medial olivocochlear (MOC efferent fibers. Contralateral acoustic stimulation activates the uncrossed efferent MOC fibers reducing cochlear neural responses, thus modifying the input to the central auditory system. The chinchilla, among all studied mammals, displays the lowest percentage of uncrossed MOC fibers raising questions about the strength and frequency distribution of the contralateral-sound effect in this species. On the other hand, MOC effects on cochlear sensitivity have been mainly studied in anesthetized animals and since the MOC-neuron activity depends on the level of anesthesia, it is important to assess the influence of anesthesia in the strength of efferent effects. Seven adult chinchillas (Chinchilla laniger were chronically implanted with round-window electrodes in both cochleae. We compared the effect of contralateral sound in awake and anesthetized condition. Compound action potentials (CAP and cochlear microphonics (CM were measured in the ipsilateral cochlea in response to tones in absence and presence of contralateral sound. Control measurements performed after middle-ear muscles section in one animal discarded any possible middle-ear reflex activation. Contralateral sound produced CAP amplitude reductions in all chinchillas, with suppression effects greater by about 1-3 dB in awake than in anesthetized animals. In contrast, CM amplitude increases of up to 1.9 dB were found in only three awake chinchillas. In both conditions the strongest efferent effects were produced by contralateral tones at frequencies equal or close to those of ipsilateral tones. Contralateral CAP suppressions for 1-6 kHz ipsilateral tones corresponded to a span of uncrossed MOC fiber innervation reaching at least the central third of the

  5. Stronger efferent suppression of cochlear neural potentials by contralateral acoustic stimulation in awake than in anesthetized chinchilla.

    Science.gov (United States)

    Aedo, Cristian; Tapia, Eduardo; Pavez, Elizabeth; Elgueda, Diego; Delano, Paul H; Robles, Luis

    2015-01-01

    There are two types of sensory cells in the mammalian cochlea, inner hair cells, which make synaptic contact with auditory-nerve afferent fibers, and outer hair cells that are innervated by crossed and uncrossed medial olivocochlear (MOC) efferent fibers. Contralateral acoustic stimulation activates the uncrossed efferent MOC fibers reducing cochlear neural responses, thus modifying the input to the central auditory system. The chinchilla, among all studied mammals, displays the lowest percentage of uncrossed MOC fibers raising questions about the strength and frequency distribution of the contralateral-sound effect in this species. On the other hand, MOC effects on cochlear sensitivity have been mainly studied in anesthetized animals and since the MOC-neuron activity depends on the level of anesthesia, it is important to assess the influence of anesthesia in the strength of efferent effects. Seven adult chinchillas (Chinchilla laniger) were chronically implanted with round-window electrodes in both cochleae. We compared the effect of contralateral sound in awake and anesthetized condition. Compound action potentials (CAP) and cochlear microphonics (CM) were measured in the ipsilateral cochlea in response to tones in absence and presence of contralateral sound. Control measurements performed after middle-ear muscles section in one animal discarded any possible middle-ear reflex activation. Contralateral sound produced CAP amplitude reductions in all chinchillas, with suppression effects greater by about 1-3 dB in awake than in anesthetized animals. In contrast, CM amplitude increases of up to 1.9 dB were found in only three awake chinchillas. In both conditions the strongest efferent effects were produced by contralateral tones at frequencies equal or close to those of ipsilateral tones. Contralateral CAP suppressions for 1-6 kHz ipsilateral tones corresponded to a span of uncrossed MOC fiber innervation reaching at least the central third of the chinchilla cochlea.

  6. A case report: the first successful cochlear implant in Uganda.

    African Journals Online (AJOL)

    A case report: the first successful cochlear implant in Uganda. Richard Byaruhanga1, J. ... The patient was a 23 year old male whose presenting com- plaint was inability to .... Custom Sound by Cochlear (the company that manu- factures the ...

  7. The role of eABR with intracochlear test electrode in decision making between cochlear and brainstem implants: preliminary results.

    Science.gov (United States)

    Cinar, Betul Cicek; Yarali, Mehmet; Atay, Gamze; Bajin, Munir Demir; Sennaroglu, Gonca; Sennaroglu, Levent

    2017-09-01

    The objective of the study was to discuss the findings of intraoperative electrically evoked auditory brainstem response (eABR) test results with a recently designed intracochlear test electrode (ITE) in terms of their relation to decisions of cochlear or auditory brainstem implantation. This clinical study was conducted in Hacettepe University, Department of Otolaryngology, Head and Neck Surgery and Department of Audiology. Subjects were selected from inner ear malformation (IEM) database. Eleven subjects with profound sensorineural hearing loss were included in the current study with age range from 1 year 3 months to 4 years 3 months for children with prelingual hearing loss. There was only one 42-year-old post-lingual subject. eABR was recorded with an ITE and intraoperatively with an original cochlear implant (CI) electrode in 11 cases with different IEMs. Findings of eABR with ITE and their relation to the decision for CI or auditory brainstem implant (ABI) are discussed. Positive eABR test results were found to be dependent on close to normal cochlear structures and auditory nerve. The probability of positive result decreases with increasing degree of malformation severity. The prediction value of eABR via ITE on decision for hearing restoration was found to be questionable in this study. The results of eABR with ITE have predictive value on what we will get with the actual CI electrode. ITE appears to stimulate the cochlea like an actual CI. If the eABR is positive, the results are reliable. However, if eABR is negative, the results should be evaluated with preoperative audiological testing and MRI findings.

  8. Cochlear pathology in chronic suppurative otitis media.

    Science.gov (United States)

    Walby, A P; Barrera, A; Schuknecht, H F

    1983-01-01

    Chronic suppurative otitis media (COM) is reported to cause elevation of bone-conduction thresholds either by damage to cochlear sensorineural structures or by alteration in the mechanics of sound transmission in the ear. A retrospective study was made of the medical records of 87 patients with unilateral uncomplicated COM to document that abnormality in bone conduction does exist. In a separate study the cochlear pathology in 12 pairs of temporal bones with unilateral COM was studied by light microscopy. Infected ears showed higher than normal mean bone-conduction thresholds by amounts ranging from 1 dB at 500 Hz to 9.5 dB at 4,000 Hz. The temporal bones showed no greater loss of specialized sensorineural structures in infected ears than in normal control ears. Because there is no evidence that COM caused destruction of hair cells or cochlear neurons, alteration in the mechanics of sound transmission becomes a more plausible explanation for the hearing losses.

  9. Microanatomy of the cochlear hook

    Science.gov (United States)

    Kwan, Changyow Claire; Tan, Xiaodong; Stock, Stuart R.; Soriano, Carmen; Xiao, Xianghui; Richter, Claus-Peter

    2017-09-01

    Communication among humans occurs through coding and decoding of acoustic information. The inner ear or cochlea acts as a frequency analyzer and divides the acoustic signal into small frequency bands, which are processed at different sites along the cochlea. The mechano-electrical conversion is accomplished by the soft tissue structures in the cochlea. While the anatomy for most of the cochlea has been well described, a detailed description of the very high frequency and vulnerable cochlear hook region is missing. To study the cochlear hook, mice cochleae were imaged with synchrotron radiation and high-resolution reconstructions have been made from the tomographic scans. This is the first detailed description of the bony and soft tissues of the hook region of the mammalian cochlea.

  10. The feasibility of sugammadex for general anesthesia and facial nerve monitoring in patients undergoing parotid surgery.

    Science.gov (United States)

    Lu, I-Cheng; Chang, Pi-Ying; Su, Miao-Pei; Chen, Po-Nien; Chen, Hsiu-Ya; Chiang, Feng-Yu; Wu, Che-Wei

    2017-08-01

    The use of neuromuscular blocking agent (NMBA) during anesthesia may interfere with facial nerve monitoring (FNM) during parotid surgery. Sugammadex has been reported to be an effective and safe reversal of rocuronium-induced neuromuscular block (NMB) during surgery. This study investigated the feasibility and clinical effectiveness of sugammadex for NMB reversal during FNM in Parotid surgery. Fifty patients undergoing parotid surgery were randomized allocated into conventional anesthesia group (Group C, n = 25) and sugammadex group (Group S, n = 25). Group C did not receive any NMBA. Group S received rocuronium 0.6 mg/kg at anesthesia induction and sugammadex 2 mg/kg at skin incision. The intubating condition and influence on FNM evoked EMG results were compared between groups. The intubation condition showed significantly better in group S patients than C group patients (excellent in 96% v.s. 24%). In group S, rapid reverse of NMB was found and the twitch (%) recovered from 0 to >90% within 10 min. Positive and high EMG signals were obtained in all patients at the time point of initial facial nerve stimulation in both groups. There was no significant difference as comparing the EMG amplitudes detected at the time point of initial and final facial nerve stimulation in both groups. Implementation of sugammadex in anesthesia protocol is feasible and reliable for successful FNM during parotid surgery. Copyright © 2017. Published by Elsevier Taiwan.

  11. Intraoperative Mapping and Monitoring for Rootlets of the Lower Cranial Nerves Related to Vocal Cord Movement.

    Science.gov (United States)

    Wanibuchi, Masahiko; Akiyama, Yukinori; Mikami, Takeshi; Komatsu, Katsuya; Sugino, Toshiya; Suzuki, Kengo; Kanno, Aya; Ohtaki, Shunya; Noshiro, Shouhei; Mikuni, Nobuhiro

    2016-06-01

    Damage to the motor division of the lower cranial nerves that run into the jugular foramen leads to hoarseness, dysphagia, and the risk of aspiration pneumonia; therefore, its functional preservation during surgical procedures is important. Intraoperative mapping and monitoring of the motor rootlets at the cerebellomedullary cistern using endotracheal tube electrodes is a safe and effective procedure to prevent its injury. To study the location of the somatic and autonomic motor fibers of the lower cranial nerves related to vocal cord movement. Twenty-four patients with pathologies at the cerebellopontine lesion were studied. General anesthesia was maintained with fentanyl and propofol. A monopolar stimulator was used at amplitudes of 0.05 to 0.1 mA. Both acoustic and visual signals were displayed as vocalis muscle electromyographic activity using endotracheal tube surface electrodes. The average number of rootlets was 7.4 (range, 5-10); 75% of patients had 7 or 8 rootlets. As many as 6 rootlets (2-4 in most cases) were responsive in each patient. In 23 of the 24 patients, the responding rootlets congregated on the caudal side. The maximum electromyographic response was predominantly in the most caudal or second most caudal rootlet in 79%. The majority of motor fibers of the lower cranial nerves run through the caudal part of the rootlets at the cerebellomedullary cistern, and the maximal electromyographic response was elicited at the most caudal or second most caudal rootlet. EMG, electromyographic.

  12. Emotion Understanding in Deaf Children with a Cochlear Implant

    Science.gov (United States)

    Wiefferink, Carin H.; Rieffe, Carolien; Ketelaar, Lizet; De Raeve, Leo; Frijns, Johan H. M.

    2013-01-01

    It is still largely unknown how receiving a cochlear implant affects the emotion understanding in deaf children. We examined indices for emotion understanding and their associations with communication skills in children aged 2.5-5 years, both hearing children (n = 52) and deaf children with a cochlear implant (n = 57). 2 aspects of emotion…

  13. COCHLEAR IMPLANTATION IN A PATIENT WITH USHER'S SYNDROME

    OpenAIRE

    Derinsu, Ufuk; Ciprut, Ayca

    2016-01-01

    Usher's Syndrome is an autosomal recessive disorder characterized by congenital hearing loss and retinitis pigmentosa. Usher’s Syndrome patients with severe to profound sensorineural hearing loss can be considered as candidates for cochlear implantation.This case study reports a deaf-blind with Usher's Syndrome who received a cochlear implant, the audiological evaluation is presented and the therapy sessions are discussed. The patient demonstrated good performance overtime after the...

  14. Auditory Mechanics of the Tectorial Membrane and the Cochlear Spiral

    Science.gov (United States)

    Gavara, Núria; Manoussaki, Daphne; Chadwick, Richard S.

    2012-01-01

    Purpose of review This review is timely and relevant since new experimental and theoretical findings suggest that cochlear mechanics from the nanoscale to the macroscale are affected by mechanical properties of the tectorial membrane and the spiral shape. Recent findings Main tectorial membrane themes covered are i) composition and morphology, ii) nanoscale mechanical interactions with the outer hair cell bundle, iii) macroscale longitudinal coupling, iv) fluid interaction with inner hair cell bundles, v) macroscale dynamics and waves. Main cochlear spiral themes are macroscale low-frequency energy focusing and microscale organ of Corti shear gain. Implications Findings from new experimental and theoretical models reveal exquisite sensitivity of cochlear mechanical performance to tectorial membrane structural organization, mechanics, and its positioning with respect to hair bundles. The cochlear spiral geometry is a major determinant of low frequency hearing. Suggestions are made for future research directions. PMID:21785353

  15. [Pre-operation evaluation and intra-operation management of cochlear implantation].

    Science.gov (United States)

    Zhang, Dao-xing; Hu, Bao-hua; Xiao, Yu-li; Shi, Bo-ning

    2004-10-01

    To summarize pre-operation evaluation experiences in cochlear implantation. Performing auditory evaluation and image analysis seriously in 158 severe hearing loss or total deaf cases before cochlear implantation, comparing their performance with the findings during and post operation. Among the total 158 cases, 116 cases with normal structure, 42 cases with the abnormal findings of the inner or middle ear. Stapedial gusher happened in 6 cases, 1 case was not predicted before operation. Except 1 case with serious malformation, the findings of other 157 cases in operation were consistent with the pre-operation evaluation. We helped all patients reconstruct auditory conduction with cochlear implantation, and the average hearing level up to 37.6 dB SPL. Performing image analysis seriously before operation and planning for operation according to HRCT can do great help to cochlear implantation. The operation under the HRCT instruction has less complications.

  16. Combined KHFAC + DC nerve block without onset or reduced nerve conductivity after block

    Science.gov (United States)

    Franke, Manfred; Vrabec, Tina; Wainright, Jesse; Bhadra, Niloy; Bhadra, Narendra; Kilgore, Kevin

    2014-10-01

    Objective. Kilohertz frequency alternating current (KHFAC) waveforms have been shown to provide peripheral nerve conductivity block in many acute and chronic animal models. KHFAC nerve block could be used to address multiple disorders caused by neural over-activity, including blocking pain and spasticity. However, one drawback of KHFAC block is a transient activation of nerve fibers during the initiation of the nerve block, called the onset response. The objective of this study is to evaluate the feasibility of using charge balanced direct current (CBDC) waveforms to temporarily block motor nerve conductivity distally to the KHFAC electrodes to mitigate the block onset-response. Approach. A total of eight animals were used in this study. A set of four animals were used to assess feasibility and reproducibility of a combined KHFAC + CBDC block. A following randomized study, conducted on a second set of four animals, compared the onset response resulting from KHFAC alone and combined KHFAC + CBDC waveforms. To quantify the onset, peak forces and the force-time integral were measured during KHFAC block initiation. Nerve conductivity was monitored throughout the study by comparing muscle twitch forces evoked by supra-maximal stimulation proximal and distal to the block electrodes. Each animal of the randomized study received at least 300 s (range: 318-1563 s) of cumulative dc to investigate the impact of combined KHFAC + CBDC on nerve viability. Main results. The peak onset force was reduced significantly from 20.73 N (range: 18.6-26.5 N) with KHFAC alone to 0.45 N (range: 0.2-0.7 N) with the combined CBDC and KHFAC block waveform (p conductivity was observed after application of the combined KHFAC + CBDC block relative to KHFAC waveforms. Significance. The distal application of CBDC can significantly reduce or even completely prevent the KHFAC onset response without a change in nerve conductivity.

  17. Music Therapy for Preschool Cochlear Implant Recipients

    Science.gov (United States)

    Gfeller, Kate; Driscoll, Virginia; Kenworthy, Maura; Van Voorst, Tanya

    2010-01-01

    This paper provides research and clinical information relevant to music therapy for preschool children who use cochlear implants (CI). It consolidates information from various disciplinary sources regarding (a) cochlear implantation of young prelingually-deaf children (~age 2-5), (b) patterns of auditory and speech-language development, and (c) research regarding music perception of children with CIs. This information serves as a foundation for the final portion of the article, which describes typical music therapy goals and examples of interventions suitable for preschool children. PMID:23904691

  18. Facial Nerve Schwannoma: A Case Report, Radiological Features and Literature Review.

    Science.gov (United States)

    Pilloni, Giulia; Mico, Barbara Massa; Altieri, Roberto; Zenga, Francesco; Ducati, Alessandro; Garbossa, Diego; Tartara, Fulvio

    2017-12-22

    Facial nerve schwannoma localized in the middle fossa is a rare lesion. We report a case of a facial nerve schwannoma in a 30-year-old male presenting with facial nerve palsy. Magnetic resonance imaging (MRI) showed a 3 cm diameter tumor of the right middle fossa. The tumor was removed using a sub-temporal approach. Intraoperative monitoring allowed for identification of the facial nerve, so it was not damaged during the surgical excision. Neurological clinical examination at discharge demonstrated moderate facial nerve improvement (Grade III House-Brackmann).

  19. Effects of residual hearing on cochlear implant outcomes in children: A systematic-review.

    Science.gov (United States)

    Chiossi, Julia Santos Costa; Hyppolito, Miguel Angelo

    2017-09-01

    to investigate if preoperative residual hearing in prelingually deafened children can interfere on cochlear implant indication and outcomes. a systematic-review was conducted in five international databases up to November-2016, to locate articles that evaluated cochlear implantation in children with some degree of preoperative residual hearing. Outcomes were auditory, language and cognition performances after cochlear implant. The quality of the studies was assessed and classified according to the Oxford Levels of Evidence table - 2011. Risk of biases were also described. From the 30 articles reviewed, two types of questions were identified: (a) what are the benefits of cochlear implantation in children with residual hearing? (b) is the preoperative residual hearing a predictor of cochlear implant outcome? Studies ranged from 04 to 188 subjects, evaluating populations between 1.8 and 10.3 years old. The definition of residual hearing varied between studies. The majority of articles (n = 22) evaluated speech perception as the outcome and 14 also assessed language and speech production. There is evidence that cochlear implant is beneficial to children with residual hearing. Preoperative residual hearing seems to be valuable to predict speech perception outcomes after cochlear implantation, even though the mechanism of how it happens is not clear. More extensive researches must be conducted in order to make recommendations and to set prognosis for cochlear implants based on children preoperative residual hearing. Copyright © 2017 Elsevier B.V. All rights reserved.

  20. Hearing Preservation in Cochlear Implant Surgery

    Directory of Open Access Journals (Sweden)

    Priscila Carvalho Miranda

    2014-01-01

    Full Text Available In the past, it was thought that hearing loss patients with residual low-frequency hearing would not be good candidates for cochlear implantation since insertion was expected to induce inner ear trauma. Recent advances in electrode design and surgical techniques have made the preservation of residual low-frequency hearing achievable and desirable. The importance of preserving residual low-frequency hearing cannot be underestimated in light of the added benefit of hearing in noisy atmospheres and in music quality. The concept of electrical and acoustic stimulation involves electrically stimulating the nonfunctional, high-frequency region of the cochlea with a cochlear implant and applying a hearing aid in the low-frequency range. The principle of preserving low-frequency hearing by a “soft surgery” cochlear implantation could also be useful to the population of children who might profit from regenerative hair cell therapy in the future. Main aspects of low-frequency hearing preservation surgery are discussed in this review: its brief history, electrode design, principles and advantages of electric-acoustic stimulation, surgical technique, and further implications of this new treatment possibility for hearing impaired patients.

  1. Congenitally Deafblind Children and Cochlear Implants: Effects on Communication

    Science.gov (United States)

    Dammeyer, Jesper

    2009-01-01

    There has been much research conducted demonstrating the positive benefits of cochlear implantation (CI) in children who are deaf. Research on CI in children who are both deaf and blind, however, is lacking. The purpose of this article is to present a study of five congenitally deafblind children who received cochlear implants between 2.2 and 4.2…

  2. Reduction in spread of excitation from current focusing at multiple cochlear locations in cochlear implant users.

    Science.gov (United States)

    Padilla, Monica; Landsberger, David M

    2016-03-01

    Channel interaction from a broad spread of excitation is likely to be a limiting factor in performance by cochlear implant users. Although partial tripolar stimulation has been shown to reduce spread of excitation, the magnitude of the reduction is highly variable across subjects. Because the reduction in spread of excitation is typically only measured at one electrode for a given subject, the degree of variability across cochlear locations is unknown. The first goal of the present study was to determine if the reduction in spread of excitation observed from partial tripolar current focusing systematically varies across the cochlea. The second goal was to measure the variability in reduction of spread of excitation relative to monopolar stimulation across the cochlea. The third goal was to expand upon previous results that suggest that scaling of verbal descriptors can be used to predict the reduction in spread of excitation, by increasing the limited number of sites previously evaluated and verify the relationships remain with the larger dataset. The spread of excitation for monopolar and partial tripolar stimulation was measured at 5 cochlear locations using a psychophysical forward masking task. Results of the present study suggest that although partial tripolar stimulation typically reduces spread of excitation, the degree of reduction in spread of excitation was found to be highly variable and no effect of cochlear location was found. Additionally, subjective scaling of certain verbal descriptors (Clean/Dirty, Pure/Noisy) correlated with the reduction in spread of excitation suggesting sound quality scaling might be used as a quick clinical estimate of channels providing a reduction in spread of excitation. This quick scaling technique might help clinicians determine which patients would be most likely to benefit from a focused strategy. Copyright © 2016 Elsevier B.V. All rights reserved.

  3. Audiological outcomes of cochlear implantation in Waardenburg Syndrome

    Directory of Open Access Journals (Sweden)

    Magalhães, Ana Tereza de Matos

    2014-01-01

    Full Text Available Introduction: The most relevant clinical symptom in Waardenburg syndrome is profound bilateral sensorioneural hearing loss. Aim: To characterize and describe hearing outcomes after cochlear implantation in patients with Waardenburg syndrome to improve preoperative expectations. Method: This was an observational and retrospective study of a series of cases. Children who were diagnosed with Waardenburg syndrome and who received a multichannel cochlear implant between March 1999 and July 2012 were included in the study. Intraoperative neural response telemetry, hearing evaluation, speech perception, and speech production data before and after surgery were assessed. Results: During this period, 806 patients received a cochlear implant and 10 of these (1.2% were diagnosed with Waardenburg syndrome. Eight of the children received a Nucleus 24® implant and 1 child and 1 adult received a DigiSonic SP implant. The mean age at implantation was 44 months among the children. The average duration of use of a cochlear implant at the time of the study was 43 months. Intraoperative neural responses were present in all cases. Patients who could use the speech processor effectively had a pure tone average of 31 dB in free-field conditions. In addition, the MUSS and MAIS questionnaires revealed improvements in speech perception and production. Four patients did not have a good outcome, which might have been associated with ineffective use of the speech processor. Conclusion: Despite the heterogeneity of the group, patients with Waardenburg syndrome who received cochlear implants were found to have hearing thresholds that allowed access to speech sounds. However, patients who received early intervention and rehabilitation showed better evolution of auditory perception.

  4. Audiological outcomes of cochlear implantation in Waardenburg Syndrome.

    Science.gov (United States)

    Magalhães, Ana Tereza de Matos; Samuel, Paola Angélica; Goffi-Gomez, Maria Valeria Schimdt; Tsuji, Robinson Koji; Brito, Rubens; Bento, Ricardo Ferreira

    2013-07-01

     The most relevant clinical symptom in Waardenburg syndrome is profound bilateral sensorioneural hearing loss.  To characterize and describe hearing outcomes after cochlear implantation in patients with Waardenburg syndrome to improve preoperative expectations.  This was an observational and retrospective study of a series of cases. Children who were diagnosed with Waardenburg syndrome and who received a multichannel cochlear implant between March 1999 and July 2012 were included in the study. Intraoperative neural response telemetry, hearing evaluation, speech perception, and speech production data before and after surgery were assessed.  During this period, 806 patients received a cochlear implant and 10 of these (1.2%) were diagnosed with Waardenburg syndrome. Eight of the children received a Nucleus 24(®) implant and 1 child and 1 adult received a DigiSonic SP implant. The mean age at implantation was 44 months among the children. The average duration of use of a cochlear implant at the time of the study was 43 months. Intraoperative neural responses were present in all cases. Patients who could use the speech processor effectively had a pure tone average of 31 dB in free-field conditions. In addition, the MUSS and MAIS questionnaires revealed improvements in speech perception and production. Four patients did not have a good outcome, which might have been associated with ineffective use of the speech processor.  Despite the heterogeneity of the group, patients with Waardenburg syndrome who received cochlear implants were found to have hearing thresholds that allowed access to speech sounds. However, patients who received early intervention and rehabilitation showed better evolution of auditory perception.

  5. Barriers to pediatric cochlear implantation: A parental survey.

    Science.gov (United States)

    Yang, Charles Q; Reilly, Brian K; Preciado, Diego A

    2018-01-01

    This study aims to (1) determine barriers in the pediatric cochlear implantation process specific to publicly insured patients, wherein delayed implantation has been reported, and (2) compare the perceived barriers between publicly and privately insured patients. Tertiary care cochlear implantation center at academic pediatric hospital. Cross-sectional survey, retrospective chart review. The validated, 39 item Barriers to Care Questionnaire was administered to the parents of 80 recipients of cochlear implantation by two surgeons between 2013 and 2016. Survey results and diagnosis to implant interval were compared based on public or private insurance status. Two-tailed Mann-Whitney and Fisher's exact test was used for statistical analysis. Of 110 cochlear implants, 27 of 80 (34%) English-speaking parents completed the survey. 15 were privately insured and 12 were publicly insured. 23 of 27 respondents received cochlear implantation for pre-lingual sensorineural hearing loss. Publicly insured patients had significantly longer median time from diagnosis to implant than privately insured (19 vs. 8 mo, p = 0.01). The three worst scoring barrier categories for privately insured families in order were Pragmatics, Expectations, and Marginalization, whereas for publicly insured families it was Pragmatics, Skills, and Expectations. The worst scoring question for privately insured patients was "Having to take time off work". For the publicly insured, it was "Lack of communication." Privately insured patients reported more barriers on the Barriers to Care Questionnaire than publicly insured patients did. Although pragmatics was the worst-scoring barrier category for both groups, difficulties found on the survey ranked differently for each group. This information can help providers address disparities and access barriers for vulnerable patients. Published by Elsevier B.V.

  6. MRI of the labyrinth with volume rendering for cochlear implants candidates

    International Nuclear Information System (INIS)

    Sakata, Motomichi; Harada, Kuniaki; Shirase, Ryuji; Suzuki, Junpei; Nagahama, Hiroshi

    2009-01-01

    We demonstrated three-dimensional models of the labyrinth by volume rendering (VR) in preoperative assessment for cochlear implantation. MRI data sets were acquired in selected subjects using three-dimensional-fast spin echo sequences (3D-FSE). We produced the three-dimensional models of the labyrinth from axial heavily T2-weighted images. The three-dimensional models distinguished the scala tympani and scala vestibuli and provided multidirectional images. The optimal threshold three-dimensional models clearly showed the focal region of signal loss in the cochlear turns (47.1%) and the presence of inner ear anomalies (17.3%) in our series of patients. This study was concluded that these three-dimensional models by VR provide the oto-surgeon with precise, detailed, and easily interpreted information about the cochlear turns for cochlear implants candidates. (author)

  7. Terminal nerve: cranial nerve zero

    Directory of Open Access Journals (Sweden)

    Jorge Eduardo Duque Parra

    2006-12-01

    Full Text Available It has been stated, in different types of texts, that there are only twelve pairs of cranial nerves. Such texts exclude the existence of another cranial pair, the terminal nerve or even cranial zero. This paper considers the mentioned nerve like a cranial pair, specifying both its connections and its functional role in the migration of liberating neurons of the gonadotropic hormone (Gn RH. In this paper is also stated the hypothesis of the phylogenetic existence of a cerebral sector and a common nerve that integrates the terminal nerve with the olfactory nerves and the vomeronasals nerves which seem to carry out the odors detection function as well as in the food search, pheromone detection and nasal vascular regulation.

  8. Selective deletion of cochlear hair cells causes rapid age-dependent changes in spiral ganglion and cochlear nucleus neurons.

    Science.gov (United States)

    Tong, Ling; Strong, Melissa K; Kaur, Tejbeer; Juiz, Jose M; Oesterle, Elizabeth C; Hume, Clifford; Warchol, Mark E; Palmiter, Richard D; Rubel, Edwin W

    2015-05-20

    During nervous system development, critical periods are usually defined as early periods during which manipulations dramatically change neuronal structure or function, whereas the same manipulations in mature animals have little or no effect on the same property. Neurons in the ventral cochlear nucleus (CN) are dependent on excitatory afferent input for survival during a critical period of development. Cochlear removal in young mammals and birds results in rapid death of target neurons in the CN. Cochlear removal in older animals results in little or no neuron death. However, the extent to which hair-cell-specific afferent activity prevents neuronal death in the neonatal brain is unknown. We further explore this phenomenon using a new mouse model that allows temporal control of cochlear hair cell deletion. Hair cells express the human diphtheria toxin (DT) receptor behind the Pou4f3 promoter. Injections of DT resulted in nearly complete loss of organ of Corti hair cells within 1 week of injection regardless of the age of injection. Injection of DT did not influence surrounding supporting cells directly in the sensory epithelium or spiral ganglion neurons (SGNs). Loss of hair cells in neonates resulted in rapid and profound neuronal loss in the ventral CN, but not when hair cells were eliminated at a more mature age. In addition, normal survival of SGNs was dependent on hair cell integrity early in development and less so in mature animals. This defines a previously undocumented critical period for SGN survival. Copyright © 2015 the authors 0270-6474/15/357878-14$15.00/0.

  9. Age at implantation and auditory memory in cochlear implanted children.

    Science.gov (United States)

    Mikic, B; Miric, D; Nikolic-Mikic, M; Ostojic, S; Asanovic, M

    2014-05-01

    Early cochlear implantation, before the age of 3 years, provides the best outcome regarding listening, speech, cognition an memory due to maximal central nervous system plasticity. Intensive postoperative training improves not only auditory performance and language, but affects auditory memory as well. The aim of this study was to discover if the age at implantation affects auditory memory function in cochlear implanted children. A total of 50 cochlear implanted children aged 4 to 8 years were enrolled in this study: early implanted (1-3y) n = 27 and late implanted (4-6y) n = 23. Two types of memory tests were used: Immediate Verbal Memory Test and Forward and Backward Digit Span Test. Early implanted children performed better on both verbal and numeric tasks of auditory memory. The difference was statistically significant, especially on the complex tasks. Early cochlear implantation, before the age of 3 years, significantly improve auditory memory and contribute to better cognitive and education outcomes.

  10. Labyrinthectomy with cochlear implantation.

    Science.gov (United States)

    Zwolan, T A; Shepard, N T; Niparko, J K

    1993-05-01

    Numerous reports indicate that the cochlea remains responsive to electrical stimulation following labyrinthectomy. We report a case of a 47-year-old woman with a severe to profound sensorineural hearing loss from birth, who developed episodic vertigo with symptoms suggestive of delayed onset endolymphatic hydrops. Following 8 months of failed medical and vestibular rehabilitation management, a right-sided labyrinthectomy combined with cochlear implantation was performed without complication. Postoperatively the patient was free of vertigo. Attempts to activate the patient's device between 4 to 12 weeks after surgery were unsuccessful as stimulation of the electrodes resulted in discomfort. However, all 20 electrodes elicited comfortable hearing sensations 16 weeks postsurgery. One year after the successful activation, the patient demonstrated improved sound awareness and speech recognition with the implant when compared with preoperative performance with a hearing aid. This case study suggests that electrical detection thresholds with prosthetic stimulation may be unstable in the recently labyrinthectomized ear but supports and extends prior observations of preserved cochlear responsiveness after labyrinthectomy.

  11. 4-aminopyridine in scala media reversibly alters the cochlear potentials and suppresses electrically evoked oto-acoustic emissions.

    Science.gov (United States)

    Kirk, D L; Yates, G K

    1998-01-01

    Iontophoresis of 4-aminopyridine into scala media of the guinea pig cochlea caused elevation of the thresholds of the compound action potential of the auditory nerve, loss of amplitude of the extracellular cochlear microphonic response (CM), increase in the endocochlear potential (EP) and reduction in the amplitude of electrically evoked oto-acoustic emissions (EEOAEs). These changes were reversible over 10-20 min. The reciprocity of the changes in the CM and the EP was consistent with an interruption of both DC and AC currents through outer hair cells (OHCs), probably by blockade of mechano-electrical transduction (MET) channels in OHCs. Reductions in EEOAEs were consistent with the extrinsically applied generating current entering the OHC via the MET channels. Implications for the activation of OHC electromotility in vivo are discussed.

  12. MR imaging of the cochlear modiolus after intratympanic administration of Gd-DTPA

    International Nuclear Information System (INIS)

    Kawai, Hisashi; Naganawa, Shinji; Ishihara, Shunichi; Sone, Michihiko; Nakashima, Tsutomu

    2010-01-01

    We evaluated whether enhancement of the cochlear modiolus could be visualized 24 hours after intratympanic injection of gadolinium diethylenetriamine penta-acetic acid (Gd-DTPA) using a 3-dimensional real inversion recovery sequence combined with a 32-channel head coil at 3 tesla. Intratympanic injection of Gd-DTPA has been reported for visualizing endolymphatic hydrops in Meniere's disease, and its use has shown communication between the cochlear perilymph and cerebrospinal fluid in the internal auditory canal. Although the cochlear modiolus has been considered the route for this communication, this has not been confirmed through direct visualization of its enhancement. We qualitatively and quantitatively evaluated the presence of contrast enhancement in the modiolus in 19 patients with clinically suspected endolymphatic hydrops or hearing loss who underwent imaging as described above. The contrast ratio (CR) between the cochlear modiolus and cerebellar white matter on the injected side was 1.09±1.23, and that on the non-injected side was -0.48±0.38 (P<0.01). In all subjects, the CR value was larger on the injected than non-injected side, and enhancement of the cochlear modiolus was also recognized visually. Intratympanic Gd-DTPA can be administered to visualize enhancement of the cochlear modiolus and may thereby reveal its functional anatomy. (author)

  13. Effects of a Word-Learning Training on Children With Cochlear Implants

    Science.gov (United States)

    Lund, Emily

    2014-01-01

    Preschool children with hearing loss who use cochlear implants demonstrate vocabulary delays when compared to their peers without hearing loss. These delays may be a result of deficient word-learning abilities; children with cochlear implants perform more poorly on rapid word-learning tasks than children with normal hearing. This study explored the malleability of rapid word learning of preschoolers with cochlear implants by evaluating the effects of a word-learning training on rapid word learning. A single-subject, multiple probe design across participants measured the impact of the training on children’s rapid word-learning performance. Participants included 5 preschool children with cochlear implants who had an expressive lexicon of less than 150 words. An investigator guided children to identify, repeat, and learn about unknown sets of words in 2-weekly sessions across 10 weeks. The probe measure, a rapid word-learning task with a different set of words than those taught during training, was collected in the baseline, training, and maintenance conditions. All participants improved their receptive rapid word-learning performance in the training condition. The functional relation indicates that the receptive rapid word-learning performance of children with cochlear implants is malleable. PMID:23981321

  14. Cochlear implantation in the Mondini inner ear malformation.

    Science.gov (United States)

    Miyamoto, R T; Robbins, A J; Myres, W A; Pope, M L

    1986-07-01

    We report the case of a profoundly deaf 4-year-old boy with congenital deafness as a result of Mondini's dysplasia. The Mondini inner ear malformation is the result of arrested labyrinthine development during embryogenesis and is characterized by both bony and membranous anomalies of the inner ear. The dysplastic cochlear anatomy does not preclude successful cochlear implantation, and electrical threshold measurements are similar to those recorded in pediatric subjects deafened as a result of other causes.

  15. Spectral-Temporal Modulated Ripple Discrimination by Children With Cochlear Implants.

    Science.gov (United States)

    Landsberger, David M; Padilla, Monica; Martinez, Amy S; Eisenberg, Laurie S

    A postlingually implanted adult typically develops hearing with an intact auditory system, followed by periods of deafness (or near deafness) and adaptation to the implant. For an early implanted child whose brain is highly plastic, the auditory system matures with consistent input from a cochlear implant. It is likely that the auditory system of early implanted cochlear implant users is fundamentally different than postlingually implanted adults. The purpose of this study is to compare the basic psychophysical capabilities and limitations of these two populations on a spectral resolution task to determine potential effects of early deprivation and plasticity. Performance on a spectral resolution task (Spectral-temporally Modulated Ripple Test [SMRT]) was measured for 20 bilaterally implanted, prelingually deafened children (between 5 and 13 years of age) and 20 hearing children within the same age range. Additionally, 15 bilaterally implanted, postlingually deafened adults, and 10 hearing adults were tested on the same task. Cochlear implant users (adults and children) were tested bilaterally, and with each ear alone. Hearing listeners (adults and children) were tested with the unprocessed SMRT and with a vocoded version that simulates an 8-channel cochlear implant. For children with normal hearing, a positive correlation was found between age and SMRT score for both the unprocessed and vocoded versions. Older hearing children performed similarly to hearing adults in both the unprocessed and vocoded test conditions. However, for children with cochlear implants, no significant relationship was found between SMRT score and chronological age, age at implantation, or years of implant experience. Performance by children with cochlear implants was poorer than performance by cochlear implanted adults. It was also found that children implanted sequentially tended to have better scores with the first implant compared with the second implant. This difference was not

  16. Rehabilitation of deaf persons with cochlear implants

    International Nuclear Information System (INIS)

    Gstoettner, W.; Hamzavi, J.; Czerny, C.

    1997-01-01

    In the last decade, the rehabilitation of postlingually deaf adults and prelingually deaf children with cochlear implants has been established as a treatment of deafness. The technological development of the implant devices and improvement of the surgical technique have led to a considerable increase of hearing performance during the last years. The postlingually deaf adults are able to use the telephone and may be integrated in their original job. Prelingually deaf children can even visit normal schools after cochlear implantation and hearing rehabilitation training. In order to preoperatively establish the state of the cochlear, radiological diagnosis of the temporal bone is necessary. High resolution computerized tomography imaging of the temporal bone with coronar and axial 1 mm slices and MRI with thin slice technique (three dimensional, T2 weighted turbo-spinecho sequence with 0.7 mm slices) have proved to be valuable according to our experience. Furthermore a postoperative synoptical X-ray, in a modified Chausse III projection, offers good information about the position of the implant and insertion of the stimulating electrode into the cochlea. (orig.) [de

  17. 部分肌松下多组颅神经监护在小脑桥脑角区肿瘤切除术患者中的应用%Intraoperative cranial nerves monitoring under partial neuromuscular relaxation during cerebellopontine angle tumor resection

    Institute of Scientific and Technical Information of China (English)

    张军; 杨程; 顾华华; 梁伟民

    2008-01-01

    Objective To evaluate the efficacy of multiple cranial nerves monitoring under partial neuromuscular relaxation during cerebellopontine angle(CPA)tumor resection.Methods Seventy elective patients undergoing CPA tumor resection via microneurosurgery were randomly allocated to 2 equal groups: Group FN receiving intraoperative facial nerve(NF)monitoring and Group MN receiving monitoring of multiple nerves:trigeminal nerve,glossopharyngeal nerve,accessory nerve or hypoglossal nerve other than the FN which were considered at risk by the neurosurgeon preoperatively.The manipulation procedure were modified according to cranial nerves monitoring and neuromuscular relaxation was maintained at train of four stimulation(TOF)=3 by continuous vencronium infusion during the acoustic neuroma resection.The function of the cranial nerves monitored were evaluated preoperatively and 8 days postoperativelv.Results Discernable and legible images of electromyographic wave complex were obtained during cranial nerve mapping and monitoring under intraoperative partial neuromuscular relaxation form all the patients.The facial nerve function of 4 patients exacerbated(from H-B grade Ⅰ-Ⅱ to gradeⅢ-Ⅳ)in both groups,and one new glossopharyngeal nerve function deficiency was found in Group FN,and one new hypoglossal nerve function deficiency was found in Group MN postoperatively.Conclusion Intraoperative cranial nenves monitoring under partial neuromuscular relaxation is feasible.Multiple cranial nerves combined with facial nerve monitoring seems unable to increase the short-term protective effects of nerve function after CPA tumor resection.%目的 评价全身麻醉下小脑桥脑角区肿瘤切除术患者中,在部分肌松条件下多组颅神经监护的效率.方法 70例择期行小脑桥脑角区肿瘤显微手术患者,随机分为两组,一组术中只进行面神经监护(FN组,n=35),

  18. MRI of the optic nerve in benign intracranial hypertension

    International Nuclear Information System (INIS)

    Gass, A.; Barker, G.J.; Riordan-Eva, P.; MacManus, D.; Sanders, M.; Tofts, P.S.; McDonald, W.I.; Moseley, I.F.; Miller, D.H.

    1996-01-01

    We investigated the MRI appearance of the optic nerve and its cerebrospinal-fluid-containing sheath in 17 patients with benign intracranial hypertension (BIH) and 15 normal controls. Using phased-array local coils, 3-mm coronal T2-weighted fat-suppressed fast spin-echo images were obtained with an in-plane resolution of < 0.39 mm. The optic nerve and its sheath were clearly differentiated. An enlarged, elongated subarachnoid space around the optic nerve was demonstrated in patients with BIH. High-resolution MRI of the optic nerve offers additional information which may be of value for diagnosis and in planning and monitoring treatment. (orig.). With 5 figs

  19. The Hearing Outcomes of Cochlear Implantation in Waardenburg Syndrome

    OpenAIRE

    Koyama, Hajime; Kashio, Akinori; Sakata, Aki; Tsutsumiuchi, Katsuhiro; Matsumoto, Yu; Karino, Shotaro; Kakigi, Akinobu; Iwasaki, Shinichi; Yamasoba, Tatsuya

    2016-01-01

    Objectives. This study aimed to determine the feasibility of cochlear implantation for sensorineural hearing loss in patients with Waardenburg syndrome. Method. A retrospective chart review was performed on patients who underwent cochlear implantation at the University of Tokyo Hospital. Clinical classification, genetic mutation, clinical course, preoperative hearing threshold, high-resolution computed tomography of the temporal bone, and postoperative hearing outcome were assessed. Result. F...

  20. The Phonemic Awareness Skills of Cochlear Implant Children and Children with Normal Hearing in Primary School

    Directory of Open Access Journals (Sweden)

    Aliakbar Dashtelei

    2015-12-01

    Full Text Available Objectives: Phonemic awareness skills have a significant impact on children speech and language. The purpose of this study was investigating the phonemic awareness skills of children with cochlear implant and normal hearing peers in primary school. Methods: phonemic awareness subscales of phonological awareness test were administered to 30 children with cochlear implantation at the first to sixth grades of primary school and 30 children with normal hearing who were matched in age with cochlear implant group. All of children were between 6 to 11 years old. Children with cochlear implant had at least 1 to 2 years of implant experience and they were over 5 years when they receive implantation. Children with cochlear implant were selected from Special education centers in Tehran and children with normal hearing were recruited from primary schools in Tehran. The phonemic awareness skills were assessed in both groups. Results: The results showed that the Mean scores of phonemic awareness skills in cochlear implant children were significantly lower than children with normal hearing (P<.0001. Discussion: children with cochlear implant, despite Cochlear implantation prosthesis, had lower performance in phonemic awareness when compared with normal hearing children. Therefore, due to importance of phonemic awareness skills in learning of literacy skills, and defects of these skills in children with cochlear implant, these skills should be assessed carefully in children with cochlear implant and rehabilitative interventions should be considered.

  1. Interest of Electrostimulation of Peripheral Motor Nerves during Percutaneous Thermal Ablation

    International Nuclear Information System (INIS)

    Tsoumakidou, Georgia; Garnon, Julien; Ramamurthy, Nitin; Buy, Xavier; Gangi, Afshin

    2013-01-01

    Purpose: We present our experience of utilizing peripheral nerve electrostimulation as a complementary monitoring technique during percutaneous thermal ablation procedures; and we highlight its utility and feasibility in the prevention of iatrogenic neurologic thermal injury. Methods: Peripheral motor nerve electrostimulation was performed in 12 patients undergoing percutaneous image-guided thermal ablations of spinal/pelvic lesions in close proximity to the spinal cord and nerve roots. Electrostimulation was used in addition to existing insulation (active warming/cooling with hydrodissection, passive insulation with CO 2 insufflation) and temperature monitoring (thermocouples) techniques. Impending neurologic deficit was defined as a visual reduction of muscle response or need for a stronger electric current to evoke muscle contraction, compared with baseline. Results: Significant reduction of the muscle response to electrostimulation was observed in three patients during the ablation, necessitating temporary interruption, followed by injection of warm/cool saline. This resulted in complete recovery of the muscle response in two cases, while for the third patient the response did not improve and the procedure was terminated. No patient experienced postoperative motor deficit. Conclusion: Peripheral motor nerve electrostimulation is a simple, easily accessible technique allowing early detection of impending neurologic injury during percutaneous image-guided thermal ablation. It complements existing monitoring techniques and provides a functional assessment along the whole length of the nerve

  2. Interest of Electrostimulation of Peripheral Motor Nerves during Percutaneous Thermal Ablation

    Energy Technology Data Exchange (ETDEWEB)

    Tsoumakidou, Georgia, E-mail: gtsoumakidou@yahoo.com; Garnon, Julien, E-mail: juliengarnon@gmail.com; Ramamurthy, Nitin, E-mail: nitin_ramamurthy@hotmail.com; Buy, Xavier, E-mail: xbuy@ymail.com; Gangi, Afshin, E-mail: gangi@unistra.fr [University Hospital of Strasbourg (France)

    2013-12-15

    Purpose: We present our experience of utilizing peripheral nerve electrostimulation as a complementary monitoring technique during percutaneous thermal ablation procedures; and we highlight its utility and feasibility in the prevention of iatrogenic neurologic thermal injury. Methods: Peripheral motor nerve electrostimulation was performed in 12 patients undergoing percutaneous image-guided thermal ablations of spinal/pelvic lesions in close proximity to the spinal cord and nerve roots. Electrostimulation was used in addition to existing insulation (active warming/cooling with hydrodissection, passive insulation with CO{sub 2} insufflation) and temperature monitoring (thermocouples) techniques. Impending neurologic deficit was defined as a visual reduction of muscle response or need for a stronger electric current to evoke muscle contraction, compared with baseline. Results: Significant reduction of the muscle response to electrostimulation was observed in three patients during the ablation, necessitating temporary interruption, followed by injection of warm/cool saline. This resulted in complete recovery of the muscle response in two cases, while for the third patient the response did not improve and the procedure was terminated. No patient experienced postoperative motor deficit. Conclusion: Peripheral motor nerve electrostimulation is a simple, easily accessible technique allowing early detection of impending neurologic injury during percutaneous image-guided thermal ablation. It complements existing monitoring techniques and provides a functional assessment along the whole length of the nerve.

  3. Probing the Electrode–Neuron Interface With Focused Cochlear Implant Stimulation

    Science.gov (United States)

    Bierer, Julie Arenberg

    2010-01-01

    Cochlear implants are highly successful neural prostheses for persons with severe or profound hearing loss who gain little benefit from hearing aid amplification. Although implants are capable of providing important spectral and temporal cues for speech perception, performance on speech tests is variable across listeners. Psychophysical measures obtained from individual implant subjects can also be highly variable across implant channels. This review discusses evidence that such variability reflects deviations in the electrode–neuron interface, which refers to an implant channel's ability to effectively stimulate the auditory nerve. It is proposed that focused electrical stimulation is ideally suited to assess channel-to-channel irregularities in the electrode–neuron interface. In implant listeners, it is demonstrated that channels with relatively high thresholds, as measured with the tripolar configuration, exhibit broader psychophysical tuning curves and smaller dynamic ranges than channels with relatively low thresholds. Broader tuning implies that frequency-specific information intended for one population of neurons in the cochlea may activate more distant neurons, and a compressed dynamic range could make it more difficult to resolve intensity-based information, particularly in the presence of competing noise. Degradation of both types of cues would negatively affect speech perception. PMID:20724356

  4. End-to-side neurorrhaphy repairs peripheral nerve injury: sensory nerve induces motor nerve regeneration.

    Science.gov (United States)

    Yu, Qing; Zhang, She-Hong; Wang, Tao; Peng, Feng; Han, Dong; Gu, Yu-Dong

    2017-10-01

    End-to-side neurorrhaphy is an option in the treatment of the long segment defects of a nerve. It involves suturing the distal stump of the disconnected nerve (recipient nerve) to the side of the intimate adjacent nerve (donor nerve). However, the motor-sensory specificity after end-to-side neurorrhaphy remains unclear. This study sought to evaluate whether cutaneous sensory nerve regeneration induces motor nerves after end-to-side neurorrhaphy. Thirty rats were randomized into three groups: (1) end-to-side neurorrhaphy using the ulnar nerve (mixed sensory and motor) as the donor nerve and the cutaneous antebrachii medialis nerve as the recipient nerve; (2) the sham group: ulnar nerve and cutaneous antebrachii medialis nerve were just exposed; and (3) the transected nerve group: cutaneous antebrachii medialis nerve was transected and the stumps were turned over and tied. At 5 months, acetylcholinesterase staining results showed that 34% ± 16% of the myelinated axons were stained in the end-to-side group, and none of the myelinated axons were stained in either the sham or transected nerve groups. Retrograde fluorescent tracing of spinal motor neurons and dorsal root ganglion showed the proportion of motor neurons from the cutaneous antebrachii medialis nerve of the end-to-side group was 21% ± 5%. In contrast, no motor neurons from the cutaneous antebrachii medialis nerve of the sham group and transected nerve group were found in the spinal cord segment. These results confirmed that motor neuron regeneration occurred after cutaneous nerve end-to-side neurorrhaphy.

  5. Is there a best side for cochlear implants in post-lingual patients?

    Science.gov (United States)

    Amaral, Maria Stella Arantes do; Damico, Thiago A; Gonçales, Alina S; Reis, Ana C M B; Isaac, Myriam de Lima; Massuda, Eduardo T; Hyppolito, Miguel Angelo

    2017-07-29

    Cochlear Implant is a sensory prosthesis capable of restoring hearing in patients with severe or profound bilateral sensorineural hearing loss. To evaluate if there is a better side to be implanted in post-lingual patients. Retrospective longitudinal study. Participants were 40 subjects, of both sex, mean age of 47 years, with post-lingual hearing loss, users of unilateral cochlear implant for more than 12 months and less than 24 months, with asymmetric auditor reserve between the ears (difference of 10dBNA, In at least one of the frequencies with a response, between the ears), divided into two groups. Group A was composed of individuals with cochlear implant in the ear with better auditory reserve and Group B with auditory reserve lower in relation to the contralateral side. There was no statistical difference for the tonal auditory threshold before and after cochlear implant. A better speech perception in pre-cochlear implant tests was present in B (20%), but the final results are similar in both groups. The cochlear implant in the ear with the worst auditory residue favors a bimodal hearing, which would allow the binaural summation, without compromising the improvement of the audiometric threshold and the speech perception. Copyright © 2017 Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial. Published by Elsevier Editora Ltda. All rights reserved.

  6. Sequential bilateral cochlear implantation in children: parents' perspective and device use.

    NARCIS (Netherlands)

    Sparreboom, M.; Leeuw, A.R.; Snik, A.F.M.; Mylanus, E.A.M.

    2012-01-01

    OBJECTIVE: The purpose of this study was (1) to measure parental expectations before surgery of a sequentially placed second cochlear implant and compare these results with parental observations postoperatively and (2) to measure device use of the second cochlear implant and compare to unilateral

  7. Topics in Modeling of Cochlear Dynamics: Computation, Response and Stability Analysis

    Science.gov (United States)

    Filo, Maurice G.

    This thesis touches upon several topics in cochlear modeling. Throughout the literature, mathematical models of the cochlea vary according to the degree of biological realism to be incorporated. This thesis casts the cochlear model as a continuous space-time dynamical system using operator language. This framework encompasses a wider class of cochlear models and makes the dynamics more transparent and easier to analyze before applying any numerical method to discretize space. In fact, several numerical methods are investigated to study the computational efficiency of the finite dimensional realizations in space. Furthermore, we study the effects of the active gain perturbations on the stability of the linearized dynamics. The stability analysis is used to explain possible mechanisms underlying spontaneous otoacoustic emissions and tinnitus. Dynamic Mode Decomposition (DMD) is introduced as a useful tool to analyze the response of nonlinear cochlear models. Cochlear response features are illustrated using DMD which has the advantage of explicitly revealing the spatial modes of vibrations occurring in the Basilar Membrane (BM). Finally, we address the dynamic estimation problem of BM vibrations using Extended Kalman Filters (EKF). Due to the limitations of noninvasive sensing schemes, such algorithms are inevitable to estimate the dynamic behavior of a living cochlea.

  8. Evidence of across-channel processing for spectral-ripple discrimination in cochlear implant listeners.

    Science.gov (United States)

    Won, Jong Ho; Jones, Gary L; Drennan, Ward R; Jameyson, Elyse M; Rubinstein, Jay T

    2011-10-01

    Spectral-ripple discrimination has been used widely for psychoacoustical studies in normal-hearing, hearing-impaired, and cochlear implant listeners. The present study investigated the perceptual mechanism for spectral-ripple discrimination in cochlear implant listeners. The main goal of this study was to determine whether cochlear implant listeners use a local intensity cue or global spectral shape for spectral-ripple discrimination. The effect of electrode separation on spectral-ripple discrimination was also evaluated. Results showed that it is highly unlikely that cochlear implant listeners depend on a local intensity cue for spectral-ripple discrimination. A phenomenological model of spectral-ripple discrimination, as an "ideal observer," showed that a perceptual mechanism based on discrimination of a single intensity difference cannot account for performance of cochlear implant listeners. Spectral modulation depth and electrode separation were found to significantly affect spectral-ripple discrimination. The evidence supports the hypothesis that spectral-ripple discrimination involves integrating information from multiple channels. © 2011 Acoustical Society of America

  9. Protective role of hydrogen sulfide against noise-induced cochlear damage: a chronic intracochlear infusion model.

    Directory of Open Access Journals (Sweden)

    Xu Li

    Full Text Available BACKGROUND: A reduction in cochlear blood flow plays an essential role in noise-induced hearing loss (NIHL. The timely regulation of cochlear perfusion determines the progression and prognosis of NIHL. Hydrogen sulfide (H(2S has attracted increasing interest as a vasodilator in cardiovascular systems. This study identified the role of H(2S in cochlear blood flow regulation and noise protection. METHODOLOGY/PRINCIPAL FINDINGS: The gene and protein expression of the H(2S synthetase cystathionine-γ-lyase (CSE in the rat cochlea was examined using immunofluorescence and real-time PCR. Cochlear CSE mRNA levels varied according to the duration of noise exposure. A chronic intracochlear infusion model was built and artificial perilymph (AP, NaHS or DL-propargylglycine (PPG were locally administered. Local sodium hydrosulfide (NaHS significantly increased cochlear perfusion post-noise exposure. Cochlear morphological damage and hearing loss were alleviated in the NaHS group as measured by conventional auditory brainstem response (ABR, cochlear scanning electron microscope (SEM and outer hair cell (OHC count. The highest percentage of OHC loss occurred in the PPG group. CONCLUSIONS/SIGNIFICANCE: Our results suggest that H(2S plays an important role in the regulation of cochlear blood flow and the protection against noise. Further studies may identify a new preventive and therapeutic perspective on NIHL and other blood supply-related inner ear diseases.

  10. Cochlear pathology: CT and MRI findings

    International Nuclear Information System (INIS)

    Martinez, Manuel; Bruno, Claudio; Martin, Eduardo; Canale, Nancy; De Luca, Laura; Spina, Juan C. h

    2002-01-01

    The authors present a retrospective analysis of 50 patients with perceptive hearing loss. The neuro physiological work-up (evoked potentials, audiometric tests and otoemissions) identified the cochlea as the site of origin of the hearing loss. The imaging studies (high resolution CT and MR, including 3D volumes) showed petrous bone trauma (n=5) infections (bacterial or viral origin) (n=12) otosclerosis (n=8), Paget disease (n=3), and labyrinthine neurinomas (n=2). The other 20 cases showed development-linked disorders (Mitchel's, Mondini, Scheibe, Alexander, and hypoplasia of the cochlear canal). Imaging with CT and MR can identify in detail the structural abnormality affecting the cochlea and occasionally the immediate peri-cochlear region (otic capsule); the affected portion of the cochlea may thus be determined. (author)

  11. Outcomes and special considerations of cochlear implantation in waardenburg syndrome.

    Science.gov (United States)

    Kontorinis, Georgios; Lenarz, Thomas; Giourgas, Alexandros; Durisin, Martin; Lesinski-Schiedat, Anke

    2011-08-01

    The objective of this study was a state-of-the-art analysis of cochlear implantation in patients with Waardenburg syndrome (WS). Twenty-five patients with WS treated with cochlear implants in our department from 1990 to 2010. The 25 patients with WS underwent 35 cochlear implantations. Hearing outcome was evaluated using HSM sentence test in 65 dB in quiet, Freiburg Monosyllabic Test, and categories of auditory performance for children and compared with that of a control group. Anatomic abnormalities of the inner ear were examined using magnetic resonance imaging and computed tomography of the temporal bones. The mean follow-up time was 8.3 years (range, 0.3-18.3 yr). The majority achieved favorable postimplantation performance with mean HSM scores of 75.3% (range, 22.6%-99%) and Freiburg Monosyllabic Test scores of 67.8% (range, 14%-95%). However, in 4 cases, the results were less satisfactory. The comparison with the control group did not reveal any statistical significance (p = 0.56). In 6 patients (24%), behavioral disorders caused temporary difficulties during the rehabilitation procedure. Except of isolated large vestibule in 1 patient, the radiological assessment of the 50 temporal bones did not reveal any temporal bone abnormalities. Most patients with WS performed well with cochlear implants. However, WS is related to behavioral disorders that may cause temporary rehabilitation difficulties. Finally, temporal bone malformations that could affect cochlear implantation are notcharacteristic of WS.

  12. Reading skills after cochlear implantation

    NARCIS (Netherlands)

    Vermeulen, A.M.

    2007-01-01

    It has frequently been found that profoundly deaf children with conventional hearing aids have difficulties with the comprehension of written text. Cochlear Implants (CIs) were expected to enhance the reading comprehension of these profoundly deaf children because they provide auditory access to

  13. Learning and Memory Processes Following Cochlear Implantation:The Missing Piece of the Puzzle

    Directory of Open Access Journals (Sweden)

    David B. Pisoni

    2016-04-01

    Full Text Available At the present time, there is no question that cochlear implants work and often work very well in quiet listening conditions for many profoundly deaf children and adults. The speech and language outcomes data published over the last two decades document quite extensively the clinically significant benefits of cochlear implants. Although there now is a large body of evidence supporting the efficacy of cochlear implants as a medical intervention for profound hearing loss in both children and adults, there still remain a number of challenging unresolved clinical and theoretical issues that deal with the effectiveness of cochlear implants in individual patients that have not yet been successfully resolved. In this paper, we review recent findings on learning and memory, two central topics in the field of cognition that have been seriously neglected in research on cochlear implants. Our research findings on sequence learning, memory and organization processes, and retrieval strategies used in verbal learning and memory of categorized word lists suggests that basic domain-general learning abilities may be the missing piece of the puzzle in terms of understanding the cognitive factors that underlie the enormous individual differences and variability routinely observed in speech and language outcomes following cochlear implantation.

  14. Language understanding and vocabulary of early cochlear implanted children

    DEFF Research Database (Denmark)

    Percy-Smith, L; Busch, GW; Sandahl, M

    2013-01-01

    The aim of the study was to identify factors associated with the level of language understanding, the level of receptive and active vocabulary, and to estimate effect-related odds ratios for cochlear implanted children's language level.......The aim of the study was to identify factors associated with the level of language understanding, the level of receptive and active vocabulary, and to estimate effect-related odds ratios for cochlear implanted children's language level....

  15. Computational tool for postoperative evaluation of cochlear implant patients

    International Nuclear Information System (INIS)

    Giacomini, Guilherme; Pavan, Ana Luiza M.; Pina, Diana R. de; Altemani, Joao M.C.; Castilho, Arthur M.

    2016-01-01

    The aim of this study was to develop a tool to calculate the insertion depth angle of cochlear implants, from computed tomography exams. The tool uses different image processing techniques, such as thresholding and active contour. Then, we compared the average insertion depth angle of three different implant manufacturers. The developed tool can be used, in the future, to compare the insertion depth angle of the cochlear implant with postoperative response of patient's hearing. (author)

  16. Psycholinguistic abilities in cochlear implant and hearing impaired children

    OpenAIRE

    Hassan, Hatem Ezzeldin; Eldin, Sally Taher Kheir; Al Kasaby, Rasha Mohamed

    2014-01-01

    Background: Many congenitally sensorineural hearing loss (SNHL) children and cochlear implant (CI) recipients develop near-normal language skills. However, there is a wide variation in individual outcomes following cochlear implantation, or using hearing aids. Some CI recipients or Hearing aids users never develop useable speech and oral language skills. The causes of this enormous variation in outcomes are only partly understood at the present time. So, the aim of this study was to assess th...

  17. Quality of life and cochlear implantation in Usher syndrome type I.

    NARCIS (Netherlands)

    Damen, G.W.J.A.; Pennings, R.J.E.; Snik, A.F.M.; Mylanus, E.A.M.

    2006-01-01

    OBJECTIVES: The objectives of this descriptive, retrospective study were to evaluate quality of life, hearing, and vision in patients with Usher syndrome type I with and without cochlear implant. METHODS: Quality of life (QoL) of 14 patients with Usher type I (USH1) with a cochlear implant (CI)

  18. Staphylococcus lugdunensis: novel organism causing cochlear implant infection

    Directory of Open Access Journals (Sweden)

    Samina Bhumbra

    2014-06-01

    Full Text Available A majority of cochlear implant infections are caused by Staphylococcus aureus or Pseudomonas aeruginosa. Reported here is a pediatric patient with a cochlear implant infection caused by methicillin-resistant Staphylococcus lugdunensis, a coagulase-negative Staphylococcus that has only recently been determined to be clinically relevant (1988. Unlike other coagulase-negative Staphylococcus, it is more aggressive, carrying a greater potential for tissue destruction. In pediatrics, the organism is uncommon, poorly described, and generally pan-susceptible. Described herein is the presentation and management of this unusual organism in a pediatric setting.

  19. Modeling and segmentation of intra-cochlear anatomy in conventional CT

    Science.gov (United States)

    Noble, Jack H.; Rutherford, Robert B.; Labadie, Robert F.; Majdani, Omid; Dawant, Benoit M.

    2010-03-01

    Cochlear implant surgery is a procedure performed to treat profound hearing loss. Since the cochlea is not visible in surgery, the physician uses anatomical landmarks to estimate the pose of the cochlea. Research has indicated that implanting the electrode in a particular cavity of the cochlea, the scala tympani, results in better hearing restoration. The success of the scala tympani implantation is largely dependent on the point of entry and angle of electrode insertion. Errors can occur due to the imprecise nature of landmark-based, manual navigation as well as inter-patient variations between scala tympani and the anatomical landmarks. In this work, we use point distribution models of the intra-cochlear anatomy to study the inter-patient variations between the cochlea and the typical anatomic landmarks, and we implement an active shape model technique to automatically localize intra-cochlear anatomy in conventional CT images, where intra-cochlear structures are not visible. This fully automatic segmentation could aid the surgeon to choose the point of entry and angle of approach to maximize the likelihood of scala tympani insertion, resulting in more substantial hearing restoration.

  20. Cochlear Damage Affects Neurotransmitter Chemistry in the Central Auditory System

    Directory of Open Access Journals (Sweden)

    Donald Albert Godfrey

    2014-11-01

    Full Text Available Tinnitus, the perception of a monotonous sound not actually present in the environment, affects nearly 20% of the population of the United States. Although there has been great progress in tinnitus research over the past 25 years, the neurochemical basis of tinnitus is still poorly understood. We review current research about the effects of various types of cochlear damage on the neurotransmitter chemistry in the central auditory system and document evidence that different changes in this chemistry can underlie similar behaviorally measured tinnitus symptoms. Most available data have been obtained from rodents following cochlear damage produced by cochlear ablation, loud sound, or ototoxic drugs. Effects on neurotransmitter systems have been measured as changes in neurotransmitter level, synthesis, release, uptake, and receptors. In this review, magnitudes of changes are presented for neurotransmitter-related amino acids, acetylcholine, and serotonin. A variety of effects have been found in these studies that may be related to animal model, survival time, type of cochlear damage, or methodology. The overall impression from the evidence presented is that any imbalance of neurotransmitter-related chemistry could disrupt auditory processing in such a way as to produce tinnitus.

  1. Interaction of tinnitus suppression and hearing ability after cochlear implantation.

    Science.gov (United States)

    Wang, Qian; Li, Jia-Nan; Lei, Guan-Xiong; Chen, Dai-Shi; Wang, Wei-Ze; Chen, Ai-Ting; Mong, Meng-Di; Li, Sun; Jiao, Qing-Shan; Yang, Shi-Ming

    2017-10-01

    To study the postoperative impact of cochlear implants (CIs) on tinnitus, as well as the impact of tinnitus on speech recognition with CI switched on. Fifty-two postlingual deafened CI recipients (21 males and 31 females) were assessed using an established Tinnitus Characteristics Questionnaire and Tinnitus Handicap Inventory (THI) before and after cochlear implantation. The tinnitus loudness was investigated when CI was switched on and off in CI recipients with persistent tinnitus. The relation between tinnitus loudness and recipients' satisfaction of cochlear implantation was analyzed by the visual analogue scale (VAS) score. With CI 'OFF', 42 CI recipients experienced tinnitus postimplant ipsilaterally and 44 contralaterally. Tinnitus was totally suppressed ipsilateral to the CI with CI 'ON' in 42.9%, partially suppressed in 42.9%, unchanged in 11.9% and aggravated in 2.4%. Tinnitus was totally suppressed contralaterally with CI 'ON' in 31.8% of CI recipients, partially suppressed in 47.7%, unchanged in 20.5%. Pearson correlation analysis showed that tinnitus loudness and the results of cochlear implant patients satisfaction was negatively correlated (r = .674, p tinnitus. The tinnitus loudness may affect patients' satisfaction with the use of CI.

  2. Improving Access for Pediatric and Adult Cochlear Implant Candidates in Ontario

    Directory of Open Access Journals (Sweden)

    Yvonne Emily James

    2016-10-01

    Full Text Available In 2011, the Ontario Ministry of Health and Long-Term Care announced the one-time allocation of $5.9 million to be shared by cochlear implant programs at five Ontario hospitals. The primary goal of this reform was to address cochlear implant wait times. More specifically, this funding was aimed at reducing adult wait times by 50% and to completely eliminate pediatric waiting lists. Prior to this funding, wait times for pediatric and adult cochlear implants were known to exceed four years. The funding was provided in response to a growing body of research that demonstrates increased speech perception and vocabulary among pediatric recipients, and pressure from parents of children on cochlear implant waiting lists, surgeons and other involved healthcare providers (e.g., auditory verbal therapists, audiologists, and speech language pathologists. The decision to increase funding was also influenced by government stakeholders who believed this one-time investment would be returned as pediatric patients reach adulthood and are better equipped to participate in mainstream (i.e., hearing society. While this one-time funding model has the potential to eliminate wait times for pediatric patients, thereby ensuring these children can access therapeutic services as early as possible, it does not address the future of cochlear implant waiting lists or the capacity of health human resources to absorb this sudden and unprecedented influx of pediatric patients.

  3. Narrow, duplicated internal auditory canal

    Energy Technology Data Exchange (ETDEWEB)

    Ferreira, T. [Servico de Neurorradiologia, Hospital Garcia de Orta, Avenida Torrado da Silva, 2801-951, Almada (Portugal); Shayestehfar, B. [Department of Radiology, UCLA Oliveview School of Medicine, Los Angeles, California (United States); Lufkin, R. [Department of Radiology, UCLA School of Medicine, Los Angeles, California (United States)

    2003-05-01

    A narrow internal auditory canal (IAC) constitutes a relative contraindication to cochlear implantation because it is associated with aplasia or hypoplasia of the vestibulocochlear nerve or its cochlear branch. We report an unusual case of a narrow, duplicated IAC, divided by a bony septum into a superior relatively large portion and an inferior stenotic portion, in which we could identify only the facial nerve. This case adds support to the association between a narrow IAC and aplasia or hypoplasia of the vestibulocochlear nerve. The normal facial nerve argues against the hypothesis that the narrow IAC is the result of a primary bony defect which inhibits the growth of the vestibulocochlear nerve. (orig.)

  4. A new computed tomography method to identify meningitis-related cochlear ossification and fibrosis before cochlear implantation.

    Science.gov (United States)

    Ichikawa, Kazunori; Kashio, Akinori; Mori, Harushi; Ochi, Atushi; Karino, Shotaro; Sakamoto, Takashi; Kakigi, Akinobu; Yamasoba, Tatsuya

    2014-04-01

    To develop a new method to determine the presence of intracochlear ossification and/or fibrosis in cochlear implantation candidates with bilateral profound deafness following meningitis. Diagnostic test assessment. A university hospital. This study involved 15 ears from 13 patients with profound deafness following meningitis who underwent cochlear implantation. These ears showed normal structures, soft tissue, partial bony occlusion, and complete bony occlusion in 4, 3, 2, and 6 ears, respectively. We measured radiodensity in Hounsfield units (HU) using 0.5-mm-thick axial high-resolution computed tomography image slices at 3 different levels in the basal turn, the fenestration, and inferior and ascending segment sites, located along the electrode-insertion path. Pixel-level analysis on the DICOM viewer yielded actual computed tomography values of intracochlear soft tissues by eliminating the partial volume effect. The values were compared with the intraoperative findings. Values for ossification (n = 12) ranged from +547 HU to +1137 HU; for fibrosis (n = 11), from +154 HU to +574 HU; and for fluid (n = 22), from -49 HU to +255 HU. From these values, we developed 2 presets of window width (WW) and window level (WL): (1) WW: 1800, WL: 1100 (200 HU to 2000 HU) and (2) WW: 1500, WL: 1250 (500 HU to 2000 HU). The results using these 2 presets corresponded well to the intraoperative findings. Our new method is easy and feasible for preoperative determination of the presence of cochlear ossification and/or fibrosis that develops following meningitis.

  5. Cochlear anatomy: CT and MR imaging

    International Nuclear Information System (INIS)

    Martinez, Manuel; Bruno, Claudio; Martin, Eduardo; Canale, Nancy; De Luca, Laura; Spina, Juan C. h

    2002-01-01

    The authors present a brief overview of the normal cochlear anatomy with CT and MR images in order to allow a more complete identification of the pathological findings in patients with perceptive hipoacusia. (author)

  6. Outcomes of short-gap sensory nerve injuries reconstructed with processed nerve allografts from a multicenter registry study.

    Science.gov (United States)

    Rinker, Brian D; Ingari, John V; Greenberg, Jeffrey A; Thayer, Wesley P; Safa, Bauback; Buncke, Gregory M

    2015-06-01

    Short-gap digital nerve injuries are a common surgical problem, but the optimal treatment modality is unknown. A multicenter database was queried and analyzed to determine the outcomes of nerve gap reconstructions between 5 and 15 mm with processed nerve allograft. The current RANGER registry is designed to continuously monitor and compile injury, repair, safety, and outcomes data. Centers followed their own standard of care for treatment and follow-up. The database was queried for digital nerve injuries with a gap between 5 and 15 mm reporting sufficient follow-up data to complete outcomes analysis. Available quantitative outcome measures were reviewed and reported. Meaningful recovery was defined by the Medical Research Council Classification (MRCC) scale at S3-S4 for sensory function. Sufficient follow-up data were available for 24 subjects (37 repairs) in the prescribed gap range. Mean age was 43 years (range, 23-81). Mean gap was 11 ± 3 (5-15) mm. Time to repair was 13 ± 42 (0-215) days. There were 25 lacerations, 8 avulsion/amputations, 2 gunshots, 1 crush injury, and 1 injury of unknown mechanism. Meaningful recovery, defined as S3-S4 on the MRCC scales, was reported in 92% of repairs. Sensory recovery of S3+ or S4 was observed in 84% of repairs. Static 2PD was 7.1 ± 2.9 mm (n = 19). Return to light touch was observed in 23 out of 32 repairs reporting Semmes-Weinstein monofilament outcomes (SWMF). There were no reported nerve adverse events. Sensory outcomes for processed nerve allografts were equivalent to historical controls for nerve autograft and exceed those of conduit. Processed nerve allografts provide an effective solution for short-gap digital nerve reconstructions. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  7. Spelling in Written Stories by School-Age Children with Cochlear Implants

    Science.gov (United States)

    Straley, Sara G.; Werfel, Krystal L.; Hendricks, Alison Eisel

    2016-01-01

    This study evaluated the spelling of 3rd to 6th grade children with cochlear implants in written stories. Spelling was analysed using traditional correct/incorrect scoring as well as the Spelling Sensitivity Score, which provides linguistic information about spelling attempts. Children with cochlear implants spelled 86 per cent of words in stories…

  8. Expressive Language Development in 45 Cochlear Implanted Children Following 2 Years of Implantation

    Directory of Open Access Journals (Sweden)

    Seyed Basir Hashemi

    2011-10-01

    Full Text Available Objectives: Profound hearing loss encounters children with delay in speech and language. As it is known language acquisition in young deaf children is a lengthy process, but cochlear implanted children have better spoken language skills than if they had not received the device. According to the importance of cochlear implant in deaf child's language development, this study evaluates the effect of different variables on child's language performance. Methods: 45 cochlear implanted children were tested, all of whom had used the device for at least 2 years. In order to evaluate the children, the NEWSHA test which is fitted for Persian speaking children was performed and language development of the children was compared through stepwise discriminant analysis. Results: After evaluation of the effect of different variables like child's age of implantation, participating in rehabilitation classes, parent's cooperation and their level of education, we came to a conclusion that the child's age of implantation and rehabilitation program significantly develop the child's language performance. Discussion: The value of cochlear implant in improvement of deaf children in speech, language perception, production and comprehension is confirmed by different studies which have been done on cochlear implanted children. Also, the present study indicates that language development in cochlear implanted children is highly related to their age of implantation and rehabilitation program.

  9. Extracellular pH monitoring for use in closed-loop vagus nerve stimulation

    Science.gov (United States)

    Cork, Simon C.; Eftekhar, Amir; Mirza, Khalid B.; Zuliani, Claudio; Nikolic, Konstantin; Gardiner, James V.; Bloom, Stephen R.; Toumazou, Christofer

    2018-02-01

    Objective. Vagal nerve stimulation (VNS) has shown potential benefits for obesity treatment; however, current devices lack physiological feedback, which limit their efficacy. Changes in extracellular pH (pHe) have shown to be correlated with neural activity, but have traditionally been measured with glass microelectrodes, which limit their in vivo applicability. Approach. Iridium oxide has previously been shown to be sensitive to fluctuations in pH and is biocompatible. Iridium oxide microelectrodes were inserted into the subdiaphragmatic vagus nerve of anaesthetised rats. Introduction of the gut hormone cholecystokinin (CCK) or distension of the stomach was used to elicit vagal nerve activity. Main results. Iridium oxide microelectrodes have sufficient pH sensitivity to readily detect changes in pHe associated with both CCK and gastric distension. Furthermore, a custom-made Matlab script was able to use these changes in pHe to automatically trigger an implanted VNS device. Significance. This is the first study to show pHe changes in peripheral nerves in vivo. In addition, the demonstration that iridium oxide microelectrodes are sufficiently pH sensitive as to measure changes in pHe associated with physiological stimuli means they have the potential to be integrated into closed-loop neurostimulating devices.

  10. Deriving cochlear delays in humans using otoacoustic emissions and auditory evoked potentials

    DEFF Research Database (Denmark)

    Pigasse, Gilles

    A great deal of the processing of incoming sounds to the auditory system occurs within the cochlear. The organ of Corti within the cochlea has differing mechanical properties along its length that broadly gives rise to frequency selectivity. Its stiffness is at maximum at the base and decreases...... relation between frequency and travel time in the cochlea defines the cochlear delay. This delay is directly associated with the signal analysis occurring in the inner ear and is therefore of primary interest to get a better knowledge of this organ. It is possible to estimate the cochlear delay by direct...... and invasive techniques, but these disrupt the normal functioning of the cochlea and are usually conducted in animals. In order to obtain an estimate of the cochlear delay that is closer to the normally functioning human cochlea, the present project investigates non-invasive methods in normal hearing adults...

  11. Speech Perception Outcomes after Cochlear Implantation in Children with GJB2/DFNB1 associated Deafness

    Directory of Open Access Journals (Sweden)

    Marina Davcheva-Chakar

    2014-03-01

    Full Text Available Background: Cochlear implants (CI for the rehabilitation of patients with profound or total bilateral sensorineural hypoacusis represent the initial use of electrical fields to provide audibility in cases where the use of sound amplifiers does not provide satisfactory results. Aims: To compare speech perception performance after cochlear implantation in children with connexin 26-associated deafness with that of a control group of children with deafness of unknown etiology. Study Design: Retrospective comparative study. Methods: During the period from 2006 to , cochlear implantation was performed on 26 children. Eighteen of these children had undergone genetic tests for mutation of the Gap Junction Protein Beta 2 (GJB2 gene. Bi-allelic GJB2 mutations were confirmed in 7 out of 18 examined children. In order to confirm whether genetic factors have influence on speech perception after cochlear implantation, we compared the post-implantation speech performance of seven children with mutations of the GBJ2 (connexin 26 gene with seven other children who had the wild type version of this particular gene. The latter were carefully matched according to the age at cochlear implantation. Speech perception performance was measured before cochlear implantation, and one and two years after implantation. All the patients were arranged in line with the appropriate speech perception category (SPC. Non-parametric tests, Friedman ANOVA and Mann-Whitney’s U test were used for statistical analysis. Results: Both groups showed similar improvements in speech perception scores after cochlear implantation. Statistical analysis did not confirm significant differences between the groups 12 and 24 months after cochlear implantation. Conclusion: The results obtained in this study showed an absence of apparent distinctions in the scores of speech perception between the two examined groups and therefore might have significant implications in selecting prognostic indicators

  12. Comparative Evaluation of Chitosan Nerve Guides with Regular or Increased Bendability for Acute and Delayed Peripheral Nerve Repair: A Comprehensive Comparison with Autologous Nerve Grafts and Muscle-in-Vein Grafts.

    Science.gov (United States)

    Stößel, Maria; Wildhagen, Vivien M; Helmecke, Olaf; Metzen, Jennifer; Pfund, Charlotte B; Freier, Thomas; Haastert-Talini, Kirsten

    2018-05-08

    Reconstruction of joint-crossing digital nerves requires the application of nerve guides with a much higher flexibility than used for peripheral nerve repair along larger bones. Nevertheless, collapse-resistance should be preserved to avoid secondary damage to the regrowing nerve tissue. In recent years, we presented chitosan nerve guides (CNGs) to be highly supportive for the regeneration of critical gap length peripheral nerve defects in the rat. Now, we evidently increased the bendability of regular CNGs (regCNGs) by developing a wavy wall structure, that is, corrugated CNGs (corrCNGs). In a comprehensive in vivo study, we compared both types of CNGs with clinical gold standard autologous nerve grafts (ANGs) and muscle-in-vein grafts (MVGs) that have recently been highlighted in the literature as a suitable alternative to ANGs. We reconstructed rat sciatic nerves over a critical gap length of 15 mm either immediately upon transection or after a delay period of 45 days. Electrodiagnostic measurements were applied to monitor functional motor recovery at 60, 90, 120, and 150 (only delayed repair) days postreconstruction. Upon explanation, tube properties were analyzed. Furthermore, distal nerve ends were evaluated using histomorphometry, while connective tissue specimens were subjected to immunohistological stainings. After 120 days (acute repair) or 150 days (delayed repair), respectively, compression-stability of regCNGs was slightly increased while it remained stable in corrCNGs. In both substudies, regCNGs and corrCNGs supported functional recovery of distal plantar muscles in a similar way and to a greater extent when compared with MVGs, while ANGs demonstrated the best support of regeneration. Anat Rec, 2018. © 2018 Wiley Periodicals, Inc. © 2018 Wiley Periodicals, Inc.

  13. Preoperative percutaneous cranial nerve mapping in head and neck surgery.

    Science.gov (United States)

    Park, Jung I

    2003-01-01

    To identify and map the course of the peripheral branches of the cranial nerve preoperatively and percutaneously. Prospective study. Preoperative percutaneous nerve mapping performed prior to the operation under deep sedation or general anesthesia without muscle paralysis. Private office surgery suite, freestanding surgery center, and regional medical centers. A total of 142 patients undergoing head and neck surgery and facial plastic surgery between August 1994 and July 1999. Monopolar probe was used for nerve stimulation. Electromyographic reading was done through intramuscular bipolar recording electrodes. The equipment used was a nerve monitor. The mandibular divisions were tested in 142 cases, the frontal division in 60 cases, the accessory nerve in 12 cases, and the hypoglossal nerve in 3 cases. Satisfactory mappings were obtained in 115 cases of the mandibular division, 49 cases of the frontal division, 8 cases of the accessory division, and 1 case of the hypoglossal nerve. Preoperative percutaneous nerve mapping is a new method of identifying the location of the peripheral branches of the cranial nerves. Identifying and mapping the course of peripheral branches of the cranial nerves safely assists the head and neck surgeon in the placement of incisions in a favorable location and in the dissection of the area involving the nerves. Mapping alerts the surgeon to an area containing a nerve and allows the surgeon to avoid just the specific area where a nerve is present, preventing large-scale abandonment of unmapped areas for fear of potential nerve damage.

  14. Evidence of across-channel processing for spectral-ripple discrimination in cochlear implant listeners a

    Science.gov (United States)

    Ho Won, Jong; Jones, Gary L.; Drennan, Ward R.; Jameyson, Elyse M.; Rubinstein, Jay T.

    2011-01-01

    Spectral-ripple discrimination has been used widely for psychoacoustical studies in normal-hearing, hearing-impaired, and cochlear implant listeners. The present study investigated the perceptual mechanism for spectral-ripple discrimination in cochlear implant listeners. The main goal of this study was to determine whether cochlear implant listeners use a local intensity cue or global spectral shape for spectral-ripple discrimination. The effect of electrode separation on spectral-ripple discrimination was also evaluated. Results showed that it is highly unlikely that cochlear implant listeners depend on a local intensity cue for spectral-ripple discrimination. A phenomenological model of spectral-ripple discrimination, as an “ideal observer,” showed that a perceptual mechanism based on discrimination of a single intensity difference cannot account for performance of cochlear implant listeners. Spectral modulation depth and electrode separation were found to significantly affect spectral-ripple discrimination. The evidence supports the hypothesis that spectral-ripple discrimination involves integrating information from multiple channels. PMID:21973363

  15. AUDITORY REHABILITATION AND BILATERAL COCHLEAR IMPLANT ON CHILD WHITH CEREBRAL PALSY

    Directory of Open Access Journals (Sweden)

    Anacléia Melo da Silva Hilgenberg

    2013-01-01

    Full Text Available OBJECTIVE: To describe the hearing and language improvement in children with cerebral palsy submitted to cochlear implantation bilaterally. METHODS: Prospective, analytical descriptive. Study case and a broad bibliographical analysis in MEDLINE/PUBMED and EMBASE including detailed analysis of the rehabilitation techniques as serial phonoaudiological appointments; Sessions of phonoterapy recorded and criterious analysis of the tests such as IT-MAIS and MacArthur analysis. The teste were applied after Bilateral Cochlear Implantation: 15, 20, 22, 31 e 38 months.RESULTS: The results obtained and bibliographical analysis showed that cochlear implantation in children with cerebral palsy and profound hearing loss is the best option at the moment to perform hearing rehabilitation. The IT-MAIS and MacArthur tests showed a big improvement at 15 and 38 months after use of the cochlear implants. The IT-MAIS test showed 40% score in the beggining and 75% at the end. Mac Arthur test revealed a big evolution at vocabulary comprehension (58 to 342 and linguistic repertory (54 to 289.

  16. Cyborgization: Deaf Education for Young Children in the Cochlear Implantation Era

    Science.gov (United States)

    Valente, Joseph Michael

    2011-01-01

    The author, who was raised oral deaf himself, recounts a visit to a school for young deaf children and discovers that young d/Deaf children and their rights are subverted by the cochlear implantation empire. The hypercapitalist, techno-manic times of cochlear implantation has wreaked havoc to the lives of not only young children with deafness but…

  17. The scala vestibuli for cochlear implantation. An anatomic study.

    Science.gov (United States)

    Gulya, A J; Steenerson, R L

    1996-02-01

    Traditionally, cochlear implantation has used the scala tympani (ST) for electrode insertion. When faced with ST ossification, the surgeon may elect to drill out the cochlea to accomplish partial electrode insertion. Theoretically, another option in this situation is to insert the electrode into the scala vestibuli (SV). To determine whether or not the dimensions of the SV are sufficient to accommodate an electrode array so as to assess the feasibility of SV cochlear implantation. The study of 20 normal human temporal bones, comparing the maximum diameter and surface area of the ST with those of the combined SV and scala media. The dimensions of the SV and scala media were comparable to those of the ST and appeared sufficient to accommodate a cochlear implant electrode array. It appears that the combination of SV and scala media is a viable alternative route for electrode insertion, at least on the basis of anatomic dimensions, in those cases in which the ST is obliterated.

  18. Effect of unilateral and simultaneous bilateral cochlear implantation on tinnitus : A Prospective Study

    NARCIS (Netherlands)

    van Zon, Alice; Smulders, Yvette E.; Ramakers, Geerte G. J.; Stegeman, Inge; Smit, Adriana L.; Van Zanten, Gijsbert A.; Stokroos, Robert J.; Hendrice, Nadia; Free, Rolien H.; Maat, Bert; Frijns, Johan H. M.; Mylanus, Emmanuel A. M.; Huinck, Wendy J.; Topsakal, Vedat; Tange, Rinze A.; Grolman, Wilko

    Objectives/HypothesisTo determine the effect of cochlear implantation on tinnitus perception in patients with severe bilateral postlingual sensorineural hearing loss and to demonstrate possible differences between unilateral and bilateral cochlear implantation. Study DesignProspective study.

  19. Free-form image registration of human cochlear μCT data using skeleton similarity as anatomical prior

    DEFF Research Database (Denmark)

    Kjer, Hans Martin; Fagertun, Jens; Vera, Sergio

    2016-01-01

    Better understanding of the anatomical variability of the human cochlear is important for the design and function of Cochlear Implants. Proper non-rigid alignment of high-resolution cochlear μCT data is a challenge for the typical cubic B-spline registration model. In this paper we study one way ...

  20. Cochlear Implantation and Single-sided Deafness: A Systematic Review of the Literature

    Directory of Open Access Journals (Sweden)

    Cabral Junior, Francisco

    2015-07-01

    Full Text Available Introduction Current data show that binaural hearing is superior to unilateral hearing, specifically in the understanding of speech in noisy environments. Furthermore, unilateral hearing reduce onés ability to localize sound. Objectives This study provides a systematic review of recent studies to evaluate the outcomes of cochlear implantation in patients with single-sided deafness (SSD with regards to speech discrimination, sound localization and tinnitus suppression. Data Synthesis We performed a search in the PubMed, Cochrane Library and Lilacs databases to assess studies related to cochlear implantation in patients with unilateral deafness. After critical appraisal, eleven studies were selected for data extraction and analysis of demographic, study design and outcome data. Conclusion Although some studies have shown encouraging results on cochlear implantation and SSD, all fail to provide a high level of evidence. Larger studies are necessary to define the tangible benefits of cochlear implantation in patients with SSD.

  1. A phone-assistive device based on Bluetooth technology for cochlear implant users.

    Science.gov (United States)

    Qian, Haifeng; Loizou, Philipos C; Dorman, Michael F

    2003-09-01

    Hearing-impaired people, and particularly hearing-aid and cochlear-implant users, often have difficulty communicating over the telephone. The intelligibility of telephone speech is considerably lower than the intelligibility of face-to-face speech. This is partly because of lack of visual cues, limited telephone bandwidth, and background noise. In addition, cellphones may cause interference with the hearing aid or cochlear implant. To address these problems that hearing-impaired people experience with telephones, this paper proposes a wireless phone adapter that can be used to route the audio signal directly to the hearing aid or cochlear implant processor. This adapter is based on Bluetooth technology. The favorable features of this new wireless technology make the adapter superior to traditional assistive listening devices. A hardware prototype was built and software programs were written to implement the headset profile in the Bluetooth specification. Three cochlear implant users were tested with the proposed phone-adapter and reported good speech quality.

  2. Long latency auditory evoked potentials in children with cochlear implants: systematic review.

    Science.gov (United States)

    Silva, Liliane Aparecida Fagundes; Couto, Maria Inês Vieira; Matas, Carla Gentile; Carvalho, Ana Claudia Martinho de

    2013-11-25

    The aim of this study was to analyze the findings on Cortical Auditory Evoked Potentials in children with cochlear implant through a systematic literature review. After formulation of research question and search of studies in four data bases with the following descriptors: electrophysiology (eletrofisiologia), cochlear implantation (implante coclear), child (criança), neuronal plasticity (plasticidade neuronal) and audiology (audiologia), were selected articles (original and complete) published between 2002 and 2013 in Brazilian Portuguese or English. A total of 208 studies were found; however, only 13 contemplated the established criteria and were further analyzed; was made data extraction for analysis of methodology and content of the studies. The results described suggest rapid changes in P1 component of Cortical Auditory Evoked Potentials in children with cochlear implants. Although there are few studies on the theme, cochlear implant has been shown to produce effective changes in central auditory path ways especially in children implanted before 3 years and 6 months of age.

  3. Intracochlear pressure measurements in scala media inform models of cochlear mechanics

    Science.gov (United States)

    Kale, Sushrut; Olson, Elizabeth S.

    2015-12-01

    In the classic view of cochlear mechanics, the cochlea is comprised of two identical fluid chambers separated by the cochlear partition (CP). In this view the traveling wave pressures in the two chambers mirror each other; they are equal in magnitude and opposite in phase. A fast pressure mode adds approximately uniformly. More recent models of cochlear mechanics take into account the structural complexity of the CP and the resulting additional mechanical modes would lead to distinct (non-symmetric) patterns of pressure and motion on the two sides of the CP. However, there was little to no physiological data that explored these predictions. To this aim, we measured intracochlear fluid pressure in scala media (SM), including measurements close to the sensory tissue, using miniaturized pressure sensors (˜ 80 μm outer diameter). Measurements were made in-vivo from the basal cochlear turn in gerbils. SM pressure was measured at two longitudinal locations in different preparations. In a subset of the experiments SM and ST (scala tympani) pressures were measured at the same longitudinal location. Traveling wave pressures were observed in both SM and ST, and showed the relative phase predicted by the classical theory. In addition, SM pressure showed spatial variations that had not been observed in ST, which points to a relatively complex CP motion on the SM side. These data both underscore the first-order validity of the classic cochlear traveling wave model, and open a new view to CP mechanics.

  4. Assessment of nerve ultrastructure by fibre-optic confocal microscopy.

    Science.gov (United States)

    Cushway, T R; Lanzetta, M; Cox, G; Trickett, R; Owen, E R

    1996-01-01

    Fibre-optic technology combined with confocality produces a microscope capable of optical thin sectioning. In this original study, tibial nerves have been stained in a rat model with a vital dye, 4-(4-diethylaminostyryl)-N-methylpyridinium iodide, and analysed by fibre-optic confocal microscopy to produce detailed images of nerve ultrastructure. Schwann cells, nodes of Ranvier and longitudinal myelinated sheaths enclosing axons were clearly visible. Single axons appeared as brightly staining longitudinal structures. This allowed easy tracing of multiple signal axons within the nerve tissue. An accurate measurement of internodal lengths was easily accomplished. This technique is comparable to current histological techniques, but does not require biopsy, thin sectioning or tissue fixing. This study offers a standard for further in vivo microscopy, including the possibility of monitoring the progression of nerve regeneration following microsurgical neurorraphy.

  5. Assessment of morphological-functional state of children with cochlear implants

    Directory of Open Access Journals (Sweden)

    V.M. Pysanko

    2016-10-01

    Full Text Available Purpose: assessment of morphological-functional state of pre-school age children with cochlear implants and substantiation of need in post-operative rehabilitation in period of preparation for comprehensive school. Material: we tested weakly hearing children with cochlear implants (n=127, age - 5.6±0.6 years. They were the main group. Control group consisted of children with normal hearing (n=70, age - 5.7±0.4 years. Morphological-functional state was assessed by indicators of physical and biological condition, visual analyzer, posture parameters and foot arch, muscular system and level of coordination. We calculated index of integral morphological-functional state assessment. Results: Morphological functional state of most of children (with cochlear implants was characterized by low physical condition indicators and disharmony. We observed delay in biological development. Index of morphological-functional state integral assessment witnesses, that such child can not study in comprehensive school. Rehabilitation program can reduce the gap between children with normal hearing and those with cochlear implants. Conclusions: Rehabilitation program facilitates quicker domestic and social rehabilitation of children at the account of widening the circle of communication, learning new actions and conceptions. It can permit for such children to study at school together with their healthy peers.

  6. Nerve Blocks

    Science.gov (United States)

    ... News Physician Resources Professions Site Index A-Z Nerve Blocks A nerve block is an injection to ... the limitations of Nerve Block? What is a Nerve Block? A nerve block is an anesthetic and/ ...

  7. Selective Vulnerability of the Cochlear Basal Turn to Acrylonitrile and Noise

    International Nuclear Information System (INIS)

    Pouyatos, B.; Gearhart, C.A.; Miller, A.N.; Fulton, S.; Fechter, L.D.; Pouyatos, B.

    2009-01-01

    Exposure to acrylonitrile, a high-production industrial chemical, can promote noise-induced hearing loss (NIHL) in the rat even though this agent does not itself produce permanent hearing loss. The mechanism by which acrylonitrile promotes NIHL includes oxidative stress as antioxidant drugs can partially protect the cochlea from acrylonitrile + noise. Acrylonitrile depletes glutathione levels while noise can increase the formation of reactive oxygen species. It was previously noted that the high-frequency or basal turn of the cochlea was particularly vulnerable to the combined effects of acrylonitrile and noise when the octave band noise (OBN) was centered at 8 k Hz. Normally, such a noise would be expected to yield damage at a more apical region of the cochlea. The present study was designed to determine whether the basal cochlea is selectively sensitive to acrylonitrile or whether, by adjusting the frequency of the noise band, it would be possible to control the region of the auditory impairment. Rats were exposed to one of three different OBNs centered at different frequencies (4 k Hz, 110 dB and 8 or 16 k Hz at 97 dB) for 5 days, with and without administration of acrylonitrile (50 mg/kg/day). The noise was set to cause limited NIHL by itself. Auditory function was monitored by recording distortion products, by compound action potentials, and by performing cochlear histology. While the ACN-only and noise-only exposures induced no or little permanent auditory loss, the three exposures to acrylonitrile + noise produced similar auditory and cochlear impairments above 16 k Hz, despite the fact that the noise exposures covered 2 octaves. These observations show that the basal cochlea is much more sensitive to acrylonitrile + noise than the apical partition. They provide an initial basis for distinguishing the pattern of cochlear injury that results from noise exposure from that which occurs due to the combined effects of noise and a chemical contaminant.

  8. Clinical outcomes of scala vestibuli cochlear implantation in children with partial labyrinthine ossification.

    Science.gov (United States)

    Lin, Yung-Song

    2009-03-01

    Cochlear implantation via the scala vestibuli is a viable approach in those with ossification in the scala tympani. With extended cochlear implant experience, there is no significant difference in the mapping parameters and auditory performance between those implanted via scala vestibuli and via scala tympani. To assess the clinical outcomes of cochlear implantation via scala vestibuli. In a cohort follow-up study, 11 prelingually deafened children who received cochlear implantation between age 3 and 10 years through the scala vestibuli served as participants. The mapping parameters (i.e. comfortable level (C), threshold level (T), dynamic range) and auditory performance of each participant were evaluated following initial cochlear implant stimulation, then at 3 month intervals for 2 years, then semi-annually. The follow-up period lasted for 9 years 9 months on average, with a minimum of 8 years 3 months. The clinical results of the mapping parameters and auditory performance of children implanted via the scala vestibuli were comparative to those who were implanted via the scala tympani. No balance problem was reported by any of these patients. One child exhibited residual low frequency hearing after implantation.

  9. Cochlear implants and spoken language processing abilities: review and assessment of the literature.

    Science.gov (United States)

    Peterson, Nathaniel R; Pisoni, David B; Miyamoto, Richard T

    2010-01-01

    Cochlear implants (CIs) process sounds electronically and then transmit electric stimulation to the cochlea of individuals with sensorineural deafness, restoring some sensation of auditory perception. Many congenitally deaf CI recipients achieve a high degree of accuracy in speech perception and develop near-normal language skills. Post-lingually deafened implant recipients often regain the ability to understand and use spoken language with or without the aid of visual input (i.e. lip reading). However, there is wide variation in individual outcomes following cochlear implantation, and some CI recipients never develop useable speech and oral language skills. The causes of this enormous variation in outcomes are only partly understood at the present time. The variables most strongly associated with language outcomes are age at implantation and mode of communication in rehabilitation. Thus, some of the more important factors determining success of cochlear implantation are broadly related to neural plasticity that appears to be transiently present in deaf individuals. In this article we review the expected outcomes of cochlear implantation, potential predictors of those outcomes, the basic science regarding critical and sensitive periods, and several new research directions in the field of cochlear implantation.

  10. The contribution of short-term memory capacity to reading ability in adolescents with cochlear implants.

    Science.gov (United States)

    Edwards, Lindsey; Aitkenhead, Lynne; Langdon, Dawn

    2016-11-01

    This study aimed to establish the relationship between short-term memory capacity and reading skills in adolescents with cochlear implants. A between-groups design compared a group of young people with cochlear implants with a group of hearing peers on measures of reading, and auditory and visual short-term memory capacity. The groups were matched for non-verbal IQ and age. The adolescents with cochlear implants were recruited from the Cochlear Implant Programme at a specialist children's hospital. The hearing participants were recruited from the same schools as those attended by the implanted adolescents. Participants were 18 cochlear implant users and 14 hearing controls, aged between 12 and 18 years. All used English as their main language and had no significant learning disability or neuro-developmental disorder. Short-term memory capacity was assessed in the auditory modality using Forward and Reverse Digit Span from the WISC IV UK, and visually using Forward and Reverse Memory from the Leiter-R. Individual word reading, reading comprehension and pseudoword decoding were assessed using the WIAT II UK. A series of ANOVAs revealed that the adolescents with cochlear implants had significantly poorer auditory short-term memory capacity and reading skills (on all measures) compared with their hearing peers. However, when Forward Digit Span was entered into the analyses as a covariate, none of the differences remained statistically significant. Deficits in immediate auditory memory persist into adolescence in deaf children with cochlear implants. Short-term auditory memory capacity is an important neurocognitive process in the development of reading skills after cochlear implantation in childhood that remains evident in later adolescence. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  11. Aspects of Music with Cochlear Implants – Music Listening Habits and Appreciation in Danish Cochlear Implant Users

    DEFF Research Database (Denmark)

    Petersen, Bjørn; Hansen, Mads; Sørensen, Stine Derdau

    Cochlear implant users differ significantly from their normal hearing peers when it comes to perception of music. Several studies have shown that structural features – such as rhythm, timbre, and pitch – are transmitted less accurately through an implant. However, we cannot predict personal...... music less post-implantation than prior to their hearing loss. Nevertheless, a large majority of CI listeners either prefer music over not hearing music at all or find music as pleasant as they recall it before their hearing loss, or more so....... enjoyment of music solely as a function of accuracy of perception. But can music be pleasant with a cochlear implant at all? Our aim here was to gather information of both music enjoyment and listening habits before the onset of hearing loss and post-operation from a large, representative sample of Danish...

  12. Morphological correlates of hearing loss after cochlear implantation and electro-acoustic stimulation in a hearing-impaired Guinea pig model.

    Science.gov (United States)

    Reiss, Lina A J; Stark, Gemaine; Nguyen-Huynh, Anh T; Spear, Kayce A; Zhang, Hongzheng; Tanaka, Chiemi; Li, Hongzhe

    2015-09-01

    Hybrid or electro-acoustic stimulation (EAS) cochlear implants (CIs) are designed to provide high-frequency electric hearing together with residual low-frequency acoustic hearing. However, 30-50% of EAS CI recipients lose residual hearing after implantation. The objective of this study was to determine the mechanisms of EAS-induced hearing loss in an animal model with high-frequency hearing loss. Guinea pigs were exposed to 24 h of noise (12-24 kHz at 116 dB) to induce a high-frequency hearing loss. After recovery, two groups of animals were implanted (n = 6 per group), with one group receiving chronic acoustic and electric stimulation for 10 weeks, and the other group receiving no stimulation during this time frame. A third group (n = 6) was not implanted, but received chronic acoustic stimulation. Auditory brainstem responses were recorded biweekly to monitor changes in hearing. The organ of Corti was immunolabeled with phalloidin, anti-CtBP2, and anti-GluR2 to quantify hair cells, ribbons and post-synaptic receptors. The lateral wall was immunolabeled with phalloidin and lectin to quantify stria vascularis capillary diameters. Bimodal or trimodal diameter distributions were observed; the number and location of peaks were objectively determined using the Aikake Information Criterion and Expectation Maximization algorithm. Noise exposure led to immediate hearing loss at 16-32 kHz for all groups. Cochlear implantation led to additional hearing loss at 4-8 kHz; this hearing loss was negatively and positively correlated with minimum and maximum peaks of the bimodal or trimodal distributions of stria vascularis capillary diameters, respectively. After chronic stimulation, no significant group changes in thresholds were seen; however, elevated thresholds at 1 kHz in implanted, stimulated animals were significantly correlated with decreased presynaptic ribbon and postsynaptic receptor counts. Inner and outer hair cell counts did not differ between groups and

  13. Quantifying Demyelination in NK venom treated nerve using its electric circuit model.

    Science.gov (United States)

    Das, H K; Das, D; Doley, R; Sahu, P P

    2016-03-02

    Reduction of myelin in peripheral nerve causes critical demyelinating diseases such as chronic inflammatory demyelinating polyneuropathy, Guillain-Barre syndrome, etc. Clinical monitoring of these diseases requires rapid and non-invasive quantification of demyelination. Here we have developed formulation of nerve conduction velocity (NCV) in terms of demyelination considering electric circuit model of a nerve having bundle of axons for its quantification from NCV measurements. This approach has been validated and demonstrated with toad nerve model treated with crude Naja kaouthia (NK) venom and also shows the effect of Phospholipase A2 and three finger neurotoxin from NK-venom on peripheral nerve. This opens future scope for non-invasive clinical measurement of demyelination.

  14. Quantifying Demyelination in NK venom treated nerve using its electric circuit model

    Science.gov (United States)

    Das, H. K.; Das, D.; Doley, R.; Sahu, P. P.

    2016-03-01

    Reduction of myelin in peripheral nerve causes critical demyelinating diseases such as chronic inflammatory demyelinating polyneuropathy, Guillain-Barre syndrome, etc. Clinical monitoring of these diseases requires rapid and non-invasive quantification of demyelination. Here we have developed formulation of nerve conduction velocity (NCV) in terms of demyelination considering electric circuit model of a nerve having bundle of axons for its quantification from NCV measurements. This approach has been validated and demonstrated with toad nerve model treated with crude Naja kaouthia (NK) venom and also shows the effect of Phospholipase A2 and three finger neurotoxin from NK-venom on peripheral nerve. This opens future scope for non-invasive clinical measurement of demyelination.

  15. Listening Effort With Cochlear Implant Simulations

    NARCIS (Netherlands)

    Pals, Carina; Sarampalis, Anastasios; Başkent, Deniz

    2013-01-01

    Purpose: Fitting a cochlear implant (CI) for optimal speech perception does not necessarily optimize listening effort. This study aimed to show that listening effort may change between CI processing conditions for which speech intelligibility remains constant. Method: Nineteen normal-hearing

  16. Advancing Binaural Cochlear Implant Technology

    Directory of Open Access Journals (Sweden)

    Mathias Dietz

    2015-12-01

    Full Text Available This special issue contains a collection of 13 papers highlighting the collaborative research and engineering project entitled Advancing Binaural Cochlear Implant Technology—ABCIT—as well as research spin-offs from the project. In this introductory editorial, a brief history of the project is provided, alongside an overview of the studies.

  17. Meningitis after cochlear implantation in Mondini malformation.

    Science.gov (United States)

    Page, E L; Eby, T L

    1997-01-01

    Although the potential for CSF leakage and subsequent meningitis after cochlear implantation in the malformed cochlea has been recognized, this complication has not been previously reported. We report a case of CSF otorhinorrhea and meningitis after minor head trauma developing 2 years after cochlear implantation in a child with Mondini malformation. Leakage of CSF was identified from the cochleostomy around the electrode of the implant, and this leak was sealed with a temporalis fascia and muscle plug. Although this complication appears to be rare, care must be taken to seal the cochleostomy in children with inner ear malformations at the initial surgery, and any episode of meningitis after surgery must be thoroughly investigated to rule out CSF leakage from the labyrinth.

  18. Case study of physiotherapeutic treatment of patient with diagnosis facial nerve peripheral palsy

    OpenAIRE

    Zahrádková, Tereza

    2015-01-01

    Title of Bachelorʼs thesis: Case study of physiotherapeutic treatment of patient with diagnosis facial nerve peripheral palsy. Aim of thesis: Summary of theoretical findings of patientʼs diagnosis, study metodology of physiotherapeutic care, treatment design, monitoring of treatment, and evaluate the effect of patient with diagnosis facial nerve peripheral palsy. Summary: This thesis comprehensively summarizes the findings of of peripheral facial nerve palsy and it's treatment with physiotera...

  19. Phonological working memory and its relationship with language abilities in children with cochlear implants

    Directory of Open Access Journals (Sweden)

    Fatemeh Haresabadi

    2014-12-01

    Full Text Available Background and Aim: Many studies have demonstrated a close relationship between phonological working memory and language abilities in normal children and children with language developmental disorders, such as those with cochlear implants. A review of these studies would clarify communication and learning in such children and provide more comprehensive information regarding their education and treatment. In this study, the characteristics of phonological working memory and its relationship with language abilities in children with cochlear implants was examined.Recent Findings: In this study, the authors studied the characteristics of phonological working memory and its relationship with language abilities of children with cochlear implants. These studies showed that in addition to demographic variables, phonological working memory is a factor that affects language development in children with cochlear implants. Children with cochlear implants typically have a shorter memory span.Conclusion: It is thought that the deficiency in primary auditory sensory input and language stimulation caused by difficulties in the processing and rehearsal of auditory information in phonological working memory is the main cause of the short memory span in such children. Conversely, phonological working memory problems may have adverse effects on the language abilities in such children. Therefore, to provide comprehensive and appropriate treatment for children with cochlear implants, the reciprocal relationship between language abilities and phonological working memory should be considered.

  20. Raman spectroscopic detection of peripheral nerves towards nerve-sparing surgery

    Science.gov (United States)

    Minamikawa, Takeo; Harada, Yoshinori; Takamatsu, Tetsuro

    2017-02-01

    The peripheral nervous system plays an important role in motility, sensory, and autonomic functions of the human body. Preservation of peripheral nerves in surgery, namely nerve-sparing surgery, is now promising technique to avoid functional deficits of the limbs and organs following surgery as an aspect of the improvement of quality of life of patients. Detection of peripheral nerves including myelinated and unmyelinated nerves is required for the nerve-sparing surgery; however, conventional nerve identification scheme is sometimes difficult to identify peripheral nerves due to similarity of shape and color to non-nerve tissues or its limited application to only motor peripheral nerves. To overcome these issues, we proposed a label-free detection technique of peripheral nerves by means of Raman spectroscopy. We found several fingerprints of peripheral myelinated and unmyelinated nerves by employing a modified principal component analysis of typical spectra including myelinated nerve, unmyelinated nerve, and adjacent tissues. We finally realized the sensitivity of 94.2% and the selectivity of 92.0% for peripheral nerves including myelinated and unmyelinated nerves against adjacent tissues. Although further development of an intraoperative Raman spectroscopy system is required for clinical use, our proposed approach will serve as a unique and powerful tool for peripheral nerve detection for nerve-sparing surgery in the future.

  1. Simultaneous Bilateral Cochlear Implantation for a 6-Month Child with a History of Meningitis

    Directory of Open Access Journals (Sweden)

    Kh. M. Diab

    2015-01-01

    Full Text Available The article presents the first case of simultaneous bilateral cochlear implantation for a 6-month child with IV degree sensorineural hearing loss after meningocephalitis in Russia. Despite partial ossification of the cochlear basal turns, the early timing of implantation allowed to fully implant active electrodes to both ears. The simultaneous bilateral cochlear implantation in young children, who had meningitis, is a minimally invasive and highly efficient procedure with good long-term results of oral-aural after-care.

  2. The intensity-pitch relation revisited: monopolar versus bipolar cochlear stimulation.

    Science.gov (United States)

    Arnoldner, Christoph; Riss, Dominik; Kaider, Alexandra; Mair, Alois; Wagenblast, Jens; Baumgartner, Wolf-Dieter; Gstöttner, Wolfgang; Hamzavi, Jafar-Sasan

    2008-09-01

    The very high speech perception scores now being achieved with cochlear implants have led to demands for similar levels of achievement in music perception and perception in noisy environments. One of the crucial factors in these fields is pitch perception. The aim of the present study was to investigate the extent to which pitch perception is influenced by the intensity of the stimulus, through the use of different stimulation modes (monopolar, bipolar) and different electrodes (lateral and perimodiolar). Sixteen postlingually deafened patients with an average implant use of 3.1 years were included in this study. All patients were using a Cochlear (CI24M, CI24R, CI24RE) cochlear implant. Subjects were asked to compare the pitch of an intensity-constant reference tone with the pitch of a test tone of varying intensity. The test was repeated for apical, mediocochlear, and basal channel locations, and also for monopolar and bipolar stimulation. It was found that in monopolar stimulation 87.5% and in bipolar stimulation 85.7% of the patients perceived a clear pitch change with changing intensity of the stimulus (Spearman correlation coefficients r 0.3, respectively). A total of 73.1% of these patients perceived lower pitches with increasing intensity, 26.9% reported the opposite effect. No statistically significant difference in the intensity-pitch correlation could be found between mono- and bipolar stimulation. Neither the mean dynamic range nor the type of electrode used was found to be related to the correlation coefficient. Although the majority of today's cochlear implant recipients perform well and the intensity-pitch relation in cochlear implant recipients is still poorly understood, rising demands on speech-coding strategies may soon make a compensation of the pitch shifts desirable. Although the results of our study tend to argue against a peripheral mechanism, the exact origin of this phenomenon remains unclear.

  3. Factors contributing to communication skills development in cochlear implanted children.

    Science.gov (United States)

    Ostojić, Sanja; Djoković, Sanja; Radić-šestić, Marina; Nikolić, Mina; Mikić, Branka; Mirić, Danica

    2015-08-01

    Over the last 10 years more than 300 persons received cochlear implant in Serbia and more than 90% of the recipients were children under 10 years of age. The program of cochlear implantation includes postoperative rehabilitation in which cognitive, integrative and developmental methods are used. The study was conducted to reveal factors affecting communication performance (CP) of cochlear implanted (Cl) children. Special attention was focused on the influence of the duration and intensity of rehabilitation and hearing age on further development of communication skills. A group of 30 CI children (13 boys and 17 girls) aged 2 to 5 years was enrolled in the study. All of the children had average intelligence and no other developmental disorder. They lived in families and attended rehabilitative seances 3 to 5 times a week. Their parents/caregivers answered structured questionnaire about functioning after pediatric cochlear implantation (FAPCI) and the results were the subject of detailed statistical analysis. Analysis of variance did not show any difference between the boys and the girls regarding FAPCI achievements (F(1, 28) = 2.909; p = 0.099) and age aberration in CP score (F(1,28) = 0.114, p = 0.738). Correlation analysis showed a statistically significant difference in FAPCI scores related to hearing age and duration of rehabilitation. Regression analysis (enter method) showed that model consisting of indipendent variables significantly contributed to prediction of overall FAPCI scores and Adjusted R2 value could explain 32% difference in communication skills of participants in this study. Communication skills of CI children evaluated by FAPCI are falling behind normatives for normal hearing children 18.6 months on the average. Hearing age, duration and intensity of rehabilitation have positive predictive value for communication skills development. Later identification of hearing loss and later cochlear implantation lead to delayed development of communication

  4. Cochlear implant with a non-removable magnet: preliminary research at 3-T MRI.

    Science.gov (United States)

    Dubrulle, F; Sufana Iancu, A; Vincent, C; Tourrel, G; Ernst, O

    2013-06-01

    To perform preliminary tests in vitro and with healthy volunteers to determine the 3-T MRI compatibility of a cochlear implant with a non-removable magnet. In the in vitro phase, we tested six implants for temperature changes and internal malfunctioning. We measured the demagnetisation of 65 internal magnets with different tilt angles between the implant's magnetic field (bi) and the main magnetic field (b0). In the in vivo phase, we tested 28 operational implants attached to the scalps of volunteers with the head in three different positions. The study did not find significant temperature changes or electronic malfunction in the implants tested in vitro. We found considerable demagnetisation of the cochlear implant magnets in the in vitro and in vivo testing influenced by the position of the magnet in the main magnetic field. We found that if the bi/b0 angle is 90°, there is demagnetisation in almost 60 % of the cases. When the angle is around 90°, the risk of demagnetisation is low (6.6 %). The preliminary results on cochlear implants with non-removable magnets indicate the need to maintain the contraindication of passage through 3-T MRI. • Magnetic resonance imaging can affect cochlear implants and vice versa. • Demagnetisation of cochlear implant correlates with the angle between bi and b0. • The position of the head in the MRI influences the demagnetisation. • Three-Tesla MRI for cochlear implants is still contraindicated. • However some future solutions are discussed.

  5. Prevention and management of vascular complications in middle ear and cochlear implant surgery.

    Science.gov (United States)

    Di Lella, Filippo; Falcioni, Maurizio; Piccinini, Silvia; Iaccarino, Ilaria; Bacciu, Andrea; Pasanisi, Enrico; Cerasti, Davide; Vincenti, Vincenzo

    2017-11-01

    The objective of this study is to illustrate prevention strategies and management of vascular complications from the jugular bulb (JB) and internal carotid artery (ICA) during middle ear surgery or cochlear implantation. The study design is retrospective case series. The setting is tertiary referral university hospital. Patients were included if presented pre- or intraoperative evidence of high-risk anatomical anomalies of ICA or JB during middle ear or cochlear implant surgery, intraoperative vascular injury, or revision surgery after the previous iatrogenic vascular lesions. The main outcome measures are surgical outcomes and complications rate. Ten subjects were identified: three underwent cochlear implant surgery and seven underwent middle ear surgery. Among the cochlear implant patients, two presented with anomalies of the JB impeding access to the cochlear lumen and one underwent revision surgery for incorrect positioning of the array in the carotid canal. Subtotal petrosectomy was performed in all cases. Anomalies of the JB were preoperatively identified in two patients with attic and external auditory canal cholesteatoma, respectively. In a patient, a high and dehiscent JB was found during myringoplasty, while another underwent revision surgery after iatrogenic injury of the JB. A dehiscent ICA complicated middle ear effusion in one case, while in another case, a carotid aneurysm determined a cholesterol granuloma. Rupture of a pseudoaneurysm of the ICA occurred in a child during second-stage surgery and required permanent balloon occlusion without neurological complications. Knowledge of normal anatomy and its variants and preoperative imaging are the basis for prevention of vascular complications during middle ear or cochlear implant surgery.

  6. Selecting electrode configurations for image-guided cochlear implant programming using template matching.

    Science.gov (United States)

    Zhang, Dongqing; Zhao, Yiyuan; Noble, Jack H; Dawant, Benoit M

    2018-04-01

    Cochlear implants (CIs) are neural prostheses that restore hearing using an electrode array implanted in the cochlea. After implantation, the CI processor is programmed by an audiologist. One factor that negatively impacts outcomes and can be addressed by programming is cross-electrode neural stimulation overlap (NSO). We have proposed a system to assist the audiologist in programming the CI that we call image-guided CI programming (IGCIP). IGCIP permits using CT images to detect NSO and recommend deactivation of a subset of electrodes to avoid NSO. We have shown that IGCIP significantly improves hearing outcomes. Most of the IGCIP steps are robustly automated but electrode configuration selection still sometimes requires manual intervention. With expertise, distance-versus-frequency curves, which are a way to visualize the spatial relationship learned from CT between the electrodes and the nerves they stimulate, can be used to select the electrode configuration. We propose an automated technique for electrode configuration selection. A comparison between this approach and one we have previously proposed shows that our method produces results that are as good as those obtained with our previous method while being generic and requiring fewer parameters.

  7. American parent perspectives on quality of life in pediatric cochlear implant recipients.

    Science.gov (United States)

    Kumar, Roshini; Warner-Czyz, Andrea; Silver, Cheryl H; Loy, Betty; Tobey, Emily

    2015-01-01

    Cochlear implantation influences not only communication but also psychosocial outcomes in children with severe to profound hearing loss. Focusing on issues specific to cochlear implantation (e.g., self-reliance, social relations, education, effects of implantation, and supporting the child) may provide a more accurate and relative view of functional status of pediatric cochlear implant (CI) recipients. The present study analyzes parental perspectives of CI-specific health-related quality of life (HRQoL) in children with CIs to determine (a) if parents differentially rate their child's quality of life according to psychosocial domain (e.g., communication, self-reliance, education); (b) if associations exist between quality of life domains specific to cochlear implantation in pediatric implant recipients; and (c) if demographic variables (i.e., chronologic age, age at cochlear implantation, duration of device experience) mediate parent ratings of quality of life in pediatric CI recipients. Parents of 33 children with CIs (mean age, 9.85 years; mean age of CI activation, 2.47 years; mean device experience, 7.47 years) completed a validated condition-specific questionnaire, Children With Cochlear Implants: Parental Perspectives. Parents positively rated most HRQoL domains, although education and effects of implantation received significantly less positive ratings (p self-reliance, and well-being) significantly correlated with at least 5 other domains, suggesting that positivity in one domain co-occurs with positivity in other domains. Demographic variables (chronologic age, CI activation age, and duration of CI use) did not correlate significantly with psychosocial outcomes; rather, parents reported positive HRQoL and successful functional use of CI across demographic variables. Parents of children and adolescents with CIs rate overall HRQoL positively across psychosocial domains. Significantly less positive ratings of education and effects of implantation may result

  8. Acellular Nerve Allografts in Peripheral Nerve Regeneration: A Comparative Study

    Science.gov (United States)

    Moore, Amy M.; MacEwan, Matthew; Santosa, Katherine B.; Chenard, Kristofer E.; Ray, Wilson Z.; Hunter, Daniel A.; Mackinnon, Susan E.; Johnson, Philip J.

    2011-01-01

    Background Processed nerve allografts offer a promising alternative to nerve autografts in the surgical management of peripheral nerve injuries where short deficits exist. Methods Three established models of acellular nerve allograft (cold-preserved, detergent-processed, and AxoGen® -processed nerve allografts) were compared to nerve isografts and silicone nerve guidance conduits in a 14 mm rat sciatic nerve defect. Results All acellular nerve grafts were superior to silicone nerve conduits in support of nerve regeneration. Detergent-processed allografts were similar to isografts at 6 weeks post-operatively, while AxoGen®-processed and cold-preserved allografts supported significantly fewer regenerating nerve fibers. Measurement of muscle force confirmed that detergent-processed allografts promoted isograft-equivalent levels of motor recovery 16 weeks post-operatively. All acellular allografts promoted greater amounts of motor recovery compared to silicone conduits. Conclusions These findings provide evidence that differential processing for removal of cellular constituents in preparing acellular nerve allografts affects recovery in vivo. PMID:21660979

  9. Pectoral nerves (PECS) and intercostal nerve block for cardiac resynchronization therapy device implantation.

    Science.gov (United States)

    Fujiwara, Atsushi; Komasawa, Nobuyasu; Minami, Toshiaki

    2014-01-01

    A 71-year-old man was scheduled to undergo cardiac resynchronization therapy device (CRTD) implantation. He was combined with severe chronic heart failure due to ischemic heart disease. NYHA class was 3 to 4 and electrocardiogram showed non-sustained ventricular. Ejection fraction was about 20% revealed by transthoracic echocardiogram. He was also on several anticoagulation medications. We planned to implant the device under the greater pectoral muscle. As general anesthesia was considered risky, monitored anesthesia care utilizing peripheral nerve block and slight sedation was scheduled. Pectoral nerves (PECS) block and intercostal block was performed under ultrasonography with ropivacaine. For sedation during the procedure, continuous infusion of dexmedetomidine without a loading dose was performed. The procedure lasted about 3 hours, but the patient showed no pain or restlessness. Combination of PECS block and intercostal block may provide effective analgesia for CRTD implantation.

  10. Assessment of auditory cortical function in cochlear implant patients using 15O PET

    International Nuclear Information System (INIS)

    Young, J.P.; O'Sullivan, B.T.; Gibson, W.P.; Sefton, A.E.; Mitchell, T.E.; Sanli, H.; Cervantes, R.; Withall, A.; Royal Prince Alfred Hospital, Sydney,

    1998-01-01

    Full text: Cochlear implantation has been an extraordinarily successful method of restoring hearing and the potential for full language development in pre-lingually and post-lingually deaf individuals (Gibson 1996). Post-lingually deaf patients, who develop their hearing loss later in life, respond best to cochlear implantation within the first few years of their deafness, but are less responsive to implantation after several years of deafness (Gibson 1996). In pre-lingually deaf children, cochlear implantation is most effect in allowing the full development language skills when performed within a critical period, in the first 8 years of life. These clinical observations suggest considerable neural plasticity of the human auditory cortex in acquiring and retaining language skills (Gibson 1996, Buchwald 1990). Currently, electrocochleography is used to determine the integrity of the auditory pathways to the auditory cortex. However, the functional integrity of the auditory cortex cannot be determined by this method. We have defined the extent of activation of the auditory cortex and auditory association cortex in 6 normal controls and 6 cochlear implant patients using 15 O PET functional brain imaging methods. Preliminary results have indicated the potential clinical utility of 15 O PET cortical mapping in the pre-surgical assessment and post-surgical follow up of cochlear implant patients. Copyright (1998) Australian Neuroscience Society

  11. A longitudinal study of the bilateral benefit in children with bilateral cochlear implants.

    Science.gov (United States)

    Asp, Filip; Mäki-Torkko, Elina; Karltorp, Eva; Harder, Henrik; Hergils, Leif; Eskilsson, Gunnar; Stenfelt, Stefan

    2015-02-01

    To study the development of the bilateral benefit in children using bilateral cochlear implants by measurements of speech recognition and sound localization. Bilateral and unilateral speech recognition in quiet, in multi-source noise, and horizontal sound localization was measured at three occasions during a two-year period, without controlling for age or implant experience. Longitudinal and cross-sectional analyses were performed. Results were compared to cross-sectional data from children with normal hearing. Seventy-eight children aged 5.1-11.9 years, with a mean bilateral cochlear implant experience of 3.3 years and a mean age of 7.8 years, at inclusion in the study. Thirty children with normal hearing aged 4.8-9.0 years provided normative data. For children with cochlear implants, bilateral and unilateral speech recognition in quiet was comparable whereas a bilateral benefit for speech recognition in noise and sound localization was found at all three test occasions. Absolute performance was lower than in children with normal hearing. Early bilateral implantation facilitated sound localization. A bilateral benefit for speech recognition in noise and sound localization continues to exist over time for children with bilateral cochlear implants, but no relative improvement is found after three years of bilateral cochlear implant experience.

  12. Cavernous malformations isolated from cranial nerves: Unexpected diagnosis?

    Science.gov (United States)

    Rotondo, Michele; Natale, Massimo; D'Avanzo, Raffaele; Pascale, Michela; Scuotto, Assunta

    2014-11-01

    Cranial nerves (CN) cavernous malformations (CMs) are lesions that are isolated from the CNs. The authors present three cases of CN CMs, for which MR was demonstrated to be critical for management, and surgical resection produced good outcomes for the patients. Surgical removal is the recommended course of action to restore or preserve neurological function and to eliminate the risk of future haemorrhage. However, the anatomical location and the complexity of nearby neural structures can make these lesions difficult to access and remove. In this study, the authors review the literature of reported cases of CN CMs to analyse the clinical and radiographic presentations, surgical approaches and neurological outcomes. A MEDLINE/Pub Med search was performed and revealed 86 cases of CN CMs. The authors report three additional cases in this study for a total of 89 cases. CMs affecting the optic nerve (CN II), oculomotor nerve (CN III), facial/vestibule-cochlear nerves (CN VII, CN VIII) have been described. The records of three patients were reviewed with respect to the lesion locations, symptoms, surgical approaches and therapeutic considerations. Clinical and radiological follow-up results are reported. Three patients (2 females, 1 male; age range 21-37 year) presented with three CN lesions. One lesion involved CN III, one lesion involved CN VII-CN VIII, and one involved CN II. The patient with the CN III lesion had a one-month history of mild right ptosis and diplopia. The patient with the CN VII-CN VIII lesion exhibited acute hearing loss and on the left and left facial paresis. The patient with the opticchiasmatic lesion presented with acute visual deterioration on the right and a left temporal field deficit in the left eye. Pterional and orbitozygomatic craniotomies were performed for the CN III lesion and the CN II lesion, and retrosigmoid craniotomy was performed for the cerebello-pontine angle lesion. All patients experienced symptom improvement after surgery. On

  13. [Cochlear implant in patients with congenital malformation of inner ear].

    Science.gov (United States)

    Han, Dong-yi; Wu, Wen-ming; Xi, Xin; Huang, De-liang; Yang, Wei-yan

    2004-02-01

    To study surgical difficulty and key of the cochlear implant in patients with congenital malformation of inner ear. The cochlear implantations were performed in our department from Jan. 2001 to Apr. 2003 for 18 patients with the malformation of inner ear. In this series, there were 11 cases of large vestibular aqueduct syndrome (LVAS), 3 cases of Waardenberg syndrome, 3 cases of Mondini malformation, and 1 case of Usher syndrome. All 18 patients accepted the Nucleus 24-channel cochlear implantations, including Nucleus straight electrode in 13 cases but Contour implantation in 5 cases of LVAS. During operations, leakage of perilymph but not cerebrospinal fluid (CSF) from the open of scala tympani occurred in 11 cases of LVAS, however, the electrode was inserted successfully. The abnormalities of round window occurred in one of 3 cases of Waardenberg syndrome and 3 cases of Mondini malformation, respectively. The cochlear implant could be conducted successfully for the LVAS, and the postoperative effect was same as the ones for the deafness persons with normal development of inner ear. However, for the patients with Mondini syndrome and common cavity, it is important to accurately assess the extent of abnormalities in the inner ear and accompanied malformation before operation, and to evaluate the full extent of difficulties of the operation in order to minimize the risk of CSF leakage and meningitis.

  14. Vascularized nerve grafts for lower extremity nerve reconstruction.

    Science.gov (United States)

    Terzis, Julia K; Kostopoulos, Vasileios K

    2010-02-01

    Vascularized nerve grafts (VNG) were introduced in 1976 but since then, there have been no reports of their usage in lower extremity reconstruction systematically. The factors influencing outcomes as well as a comparison with conventional nerve grafts will be presented.Since 1981, 14 lower extremity nerve injuries in 12 patients have been reconstructed with VNG. Common peroneal nerve was injured in 12 and posterior tibial nerve in 5 patients. The level of the injury was at the knee or thigh. Twelve sural nerves were used as VNG with or without concomitant vascularized posterior calf fascia.All patients regained improved sensibility and adequate posterior tibial nerve function. For common peroneal nerve reconstructions, all patients with denervation time less than 6 months regained muscle strength of grade at least 4, even when long grafts were used for defects of 20 cm or more. Late cases, yielded inadequate muscle function even with the use of VNG.Denervation time of 6 months or less was critical for reconstruction with vascularized nerve graft. Not only the results were statistically significant compared with late cases, but also all early operated patients achieved excellent results. VNG are strongly recommended in traction avulsion injuries of the lower extremity with lengthy nerve damage.

  15. Cochlear pathology following reimplantation of a multichannel scala tympani electrode array in the macaque.

    Science.gov (United States)

    Shepherd, R K; Clark, G M; Xu, S A; Pyman, B C

    1995-03-01

    The histopathologic consequence of removing and reimplanting intracochlear electrode arrays on residual auditory nerve fibers is an important issue when evaluating the safety of cochlear prostheses. The authors have examined this issue by implanting multichannel intracochlear electrodes in macaque monkeys. Macaques were selected because of the similarity of the surgical technique used to insert electrodes into the cochlea compared to that in humans, in particular the ability to insert the arrays into the upper basal turn. Five macaques were bilaterally implanted with the Melbourne/Cochlear banded electrode array. Following a minimum implant period of 5 months, the electrode array on one side of each animal was removed and another immediately implanted. The animals were sacrificed a minimum of 5 months following the reinsertion procedure, and the cochleas prepared for histopathologic analysis. Long-term implantation of the electrode resulted in a relatively mild tissue response within the cochlea. Results also showed that inner and outer hair cell survival, although significantly reduced adjacent to the array, was normal in 8 of the 10 cochleas apicalward. Moreover, the electrode reinsertion procedure did not appear to adversely affect this apical hair cell population. Significant new bone formation was frequently observed in both control and reimplanted cochleas close to the electrode fenestration site and was associated with trauma to the endosteum and/or the introduction of bone chips into the cochlea at the time of surgery. Electrode insertion trauma, involving the osseous spiral lamina or basilar membrane, was more commonly observed in reimplanted cochleas. This damage was usually restricted to the lower basal turn and resulted in a more extensive ganglion cell loss. Finally, in a number of cochleas part of the electrode array was located within the scala media or scala vestibuli. These electrodes did not appear to evoke a more extensive tissue response or

  16. Cochlear implantation in the world's largest medical device market: utilization and awareness of cochlear implants in the United States.

    Science.gov (United States)

    Sorkin, Donna L

    2013-03-01

    Provision of cochlear implants (CIs) for those within the criteria for implantation remains lower in the United States than in some other developed nations. When adults and children are grouped together, the rate of utilization/provision remains low at around 6%. For children, the provision rate is about 50% of those who could benefit from an implant, compared with figures of about 90% for the Flanders part of Belgium, the United Kingdom and other European countries. The probable reasons for this underprovision include: low awareness of the benefits of CIs among the population; low awareness among health-care professionals; the lack of specific referral pathways; some political issues relating to the Deaf Community; and financial issues related to health provision. Such financial issues result in situations which either fail to provide for access to implants or provide too low a level of the necessary funding, especially for low-income individuals covered by public health-care programs such as Medicaid. These issues might be mitigated by adoption and publication of standards for best clinical practices for CI provision, availability of current cost-effectiveness data, and the existence of an organization dedicated to cochlear implantation. Such an organization, the American Cochlear Implant Alliance (ACI Alliance), was recently organized and is described in the paper by Niparko et al. in this Supplement.

  17. CT study of 17 cases of congenital cochlear abnormality. Embryologic and anatomo-functional relationship

    OpenAIRE

    Maurício, JC; Biscoito, L; Branco, G

    1993-01-01

    In this review of cochlear malformations, 17 cases were studied by CT scan (high resolution-target program) including 10 males and 7 females. The anomaly was bilateral in 12 cases and unilateral in 7 (the latter included 2 Mondini type aplasias and one Michel). The cochlear malformation (whose most frequent expression was the cochlear hypoplasia with 1 or 1 1/2 spires-65% of the cases) was associated to semicircular canals and/or vestibular aqueduct anomaly in 82% of the patients; it was excl...

  18. Cochlear ossification in patients with profound hearing loss following bacterial meningitis

    DEFF Research Database (Denmark)

    Caye-Thomasen, Per; Dam, Mikkel Seidelin; Omland, Silje Haukali

    2012-01-01

    Cochlear ossification following bacterial meningitis is related to causative pathogen, but not age at disease or time point of evaluation. However, progression may occur over time, especially in case of primary signs of ossification.......Cochlear ossification following bacterial meningitis is related to causative pathogen, but not age at disease or time point of evaluation. However, progression may occur over time, especially in case of primary signs of ossification....

  19. Nerve Cross-Bridging to Enhance Nerve Regeneration in a Rat Model of Delayed Nerve Repair

    Science.gov (United States)

    2015-01-01

    There are currently no available options to promote nerve regeneration through chronically denervated distal nerve stumps. Here we used a rat model of delayed nerve repair asking of prior insertion of side-to-side cross-bridges between a donor tibial (TIB) nerve and a recipient denervated common peroneal (CP) nerve stump ameliorates poor nerve regeneration. First, numbers of retrogradely-labelled TIB neurons that grew axons into the nerve stump within three months, increased with the size of the perineurial windows opened in the TIB and CP nerves. Equal numbers of donor TIB axons regenerated into CP stumps either side of the cross-bridges, not being affected by target neurotrophic effects, or by removing the perineurium to insert 5-9 cross-bridges. Second, CP nerve stumps were coapted three months after inserting 0-9 cross-bridges and the number of 1) CP neurons that regenerated their axons within three months or 2) CP motor nerves that reinnervated the extensor digitorum longus (EDL) muscle within five months was determined by counting and motor unit number estimation (MUNE), respectively. We found that three but not more cross-bridges promoted the regeneration of axons and reinnervation of EDL muscle by all the CP motoneurons as compared to only 33% regenerating their axons when no cross-bridges were inserted. The same 3-fold increase in sensory nerve regeneration was found. In conclusion, side-to-side cross-bridges ameliorate poor regeneration after delayed nerve repair possibly by sustaining the growth-permissive state of denervated nerve stumps. Such autografts may be used in human repair surgery to improve outcomes after unavoidable delays. PMID:26016986

  20. Comparison of self-esteem level of adolescents with cochlear implant and normal hearing.

    Science.gov (United States)

    Sahli, Sanem; Belgin, Erol

    2006-09-01

    The purpose of this study is to compare the levels of self-esteem of adolescents with cochlear implants (before and after cochlear implantation) and the ones who have normal hearing. For this purpose, Rosenberg self-esteem scale is applied upon the study group which consists of 30 adolescents with cochlear implant between the ages of 12-19 and upon the control group which consists of 60 adolescents having the similar characteristics. The scale is used to evaluate the level of self-esteem of adolescents with cochlear implant and with normal hearing. At the end of the application, the scores of these two groups which they got according to their answers were compared statistically. When the results were examined, there seemed to be no significant difference statistically between the self-esteem values of the cochlear implant group and the control group. Apart from this, there seemed to be significant difference statistically between the self-esteem values of the before cochlear implantation and control group. In this study, we examined changes in the level of self-esteem according to different variables. As a result, it was found out that in both groups levels of self-esteem was higher for adolescents who had had preschool education, had brothers/sisters, high level of income, whose mother was working and whose father and mother had higher levels of education. On the other hand, the birth sequence and the child's father's profession did not seem to have any effect on the child's level of self-esteem. As a result of these findings, it was thought that cochlear implantation had a positive effect on life quality and it was suggested that the adolescents and their families should get assistance from experts about the characteristics and principles of approaching the child in this period. The adolescent should be directed towards social activities and courses, their positive sides should be supported and further studies should be carried out with different case groups on

  1. Cochlear Implant Outcomes and Genetic Mutations in Children with Ear and Brain Anomalies

    Directory of Open Access Journals (Sweden)

    Micol Busi

    2015-01-01

    Full Text Available Background. Specific clinical conditions could compromise cochlear implantation outcomes and drastically reduce the chance of an acceptable development of perceptual and linguistic capabilities. These conditions should certainly include the presence of inner ear malformations or brain abnormalities. The aims of this work were to study the diagnostic value of high resolution computed tomography (HRCT and magnetic resonance imaging (MRI in children with sensorineural hearing loss who were candidates for cochlear implants and to analyse the anatomic abnormalities of the ear and brain in patients who underwent cochlear implantation. We also analysed the effects of ear malformations and brain anomalies on the CI outcomes, speculating on their potential role in the management of language developmental disorders. Methods. The present study is a retrospective observational review of cochlear implant outcomes among hearing-impaired children who presented ear and/or brain anomalies at neuroimaging investigations with MRI and HRCT. Furthermore, genetic results from molecular genetic investigations (GJB2/GJB6 and, additionally, in selected cases, SLC26A4 or mitochondrial-DNA mutations on this study group were herein described. Longitudinal and cross-sectional analysis was conducted using statistical tests. Results. Between January 1, 1996 and April 1, 2012, at the ENT-Audiology Department of the University Hospital of Ferrara, 620 cochlear implantations were performed. There were 426 implanted children at the time of the present study (who were <18 years. Among these, 143 patients (64 females and 79 males presented ear and/or brain anomalies/lesions/malformations at neuroimaging investigations with MRI and HRCT. The age of the main study group (143 implanted children ranged from 9 months and 16 years (average = 4.4; median = 3.0. Conclusions. Good outcomes with cochlear implants are possible in patients who present with inner ear or brain abnormalities

  2. Nerve conduction and excitability studies in peripheral nerve disorders

    DEFF Research Database (Denmark)

    Krarup, Christian; Moldovan, Mihai

    2009-01-01

    counterparts in the peripheral nervous system, in some instances without peripheral nervous system symptoms. Both hereditary and acquired demyelinating neuropathies have been studied and the effects on nerve pathophysiology have been compared with degeneration and regeneration of axons. SUMMARY: Excitability......PURPOSE OF REVIEW: The review is aimed at providing information about the role of nerve excitability studies in peripheral nerve disorders. It has been known for many years that the insight into peripheral nerve pathophysiology provided by conventional nerve conduction studies is limited. Nerve...... excitability studies are relatively novel but are acquiring an increasingly important role in the study of peripheral nerves. RECENT FINDINGS: By measuring responses in nerve that are related to nodal function (strength-duration time constant, rheobase and recovery cycle) and internodal function (threshold...

  3. Simplifying cochlear implant speech processor fitting

    NARCIS (Netherlands)

    Willeboer, C.

    2008-01-01

    Conventional fittings of the speech processor of a cochlear implant (CI) rely to a large extent on the implant recipient's subjective responses. For each of the 22 intracochlear electrodes the recipient has to indicate the threshold level (T-level) and comfortable loudness level (C-level) while

  4. Value of MR cisternography using three-dimensional half-fourier single-shot fast spin-echo sequences in the diagnosis of diseases related to cranial nerves VII and VIII

    Energy Technology Data Exchange (ETDEWEB)

    Yamakami, Norio [Kyorin Univ., Mitaka, Tokyo (Japan). School of Medicine

    1999-05-01

    The purpose of this study was to evaluate the value of MR cisternography using three-dimensional half-Fourier single-shot fast spin-echo sequences in the diagnosis of diseasea related to cranial nerves VII and VIII. With a 0.5-T imager, the most appropriate setting of echo time and section thickness was first assessed in five volunteers. This resulted in echo time of 250 msec and section thickness of 2 mm as the most effective parameters. Second, using echo time of 120 msec and section thickness of 1.5 mm that were available from the beginning of this study, the demonstration of four nerves within the audistory canal was assessed in seven volunteers. In all of the volunteers, the facial, cochlear, and vestibular nerves were determined with demonstration of each of superior and inferior vestibular nerves in four of them. Next, MR cisternography using the same echo time and section thickness was applied in 368 patients with suspicion of acoustic neurinoma and 14 with hemifacial spasm. In 28 of the 368 patients, MR cisternograms depicted an acoustic neurinoma that was confirmed on postcontrast T1-weighted images. Meanwhile, in five of the 14 patients with hemifacial spasm, MR cisternograms revealed a vessel compressing the root exit zone of the affected facial nerve. It is concluded that MR cisternography using three-dimensional half-Fourier single-shot fast spin-echo sequences can be a useful means for demonstrating nerves within the auditory nerve as well as for the screening of acoustic neurionoma. (author)

  5. Value of MR cisternography using three-dimensional half-fourier single-shot fast spin-echo sequences in the diagnosis of diseases related to cranial nerves VII and VIII

    International Nuclear Information System (INIS)

    Yamakami, Norio

    1999-01-01

    The purpose of this study was to evaluate the value of MR cisternography using three-dimensional half-Fourier single-shot fast spin-echo sequences in the diagnosis of diseasea related to cranial nerves VII and VIII. With a 0.5-T imager, the most appropriate setting of echo time and section thickness was first assessed in five volunteers. This resulted in echo time of 250 msec and section thickness of 2 mm as the most effective parameters. Second, using echo time of 120 msec and section thickness of 1.5 mm that were available from the beginning of this study, the demonstration of four nerves within the audistory canal was assessed in seven volunteers. In all of the volunteers, the facial, cochlear, and vestibular nerves were determined with demonstration of each of superior and inferior vestibular nerves in four of them. Next, MR cisternography using the same echo time and section thickness was applied in 368 patients with suspicion of acoustic neurinoma and 14 with hemifacial spasm. In 28 of the 368 patients, MR cisternograms depicted an acoustic neurinoma that was confirmed on postcontrast T1-weighted images. Meanwhile, in five of the 14 patients with hemifacial spasm, MR cisternograms revealed a vessel compressing the root exit zone of the affected facial nerve. It is concluded that MR cisternography using three-dimensional half-Fourier single-shot fast spin-echo sequences can be a useful means for demonstrating nerves within the auditory nerve as well as for the screening of acoustic neurionoma. (author)

  6. Improving surgical results in complex nerve anatomy during implantation of selective upper airway stimulation.

    Science.gov (United States)

    Zhu, Zhaojun; Hofauer, Benedikt; Heiser, Clemens

    2018-06-01

    The following report presents a case of two late embedded hypoglossus branches during implantation of an upper airway stimulation device that caused a mixed activation of the tongue when included in the stimulation cuff. In the end, correct cuff placement could be achieved by careful examination of the hypoglossal nerve anatomy, precise nerve dissection, tongue motion analysis and intraoperative nerve monitoring. Copyright © 2018 Elsevier B.V. All rights reserved.

  7. Projections from the cochlear nuclei in the mustache bat, Pteronotus parnellii

    International Nuclear Information System (INIS)

    Zook, J.M.; Casseday, J.H.

    1985-01-01

    Ascending projections of the cochlear nuclei in the mustache bat were analyzed by anterograde transport of [ 3 H]-leucine and by retrograde transport of HRP. The authors were particularly interested in pathways to two parts of the system: (1) to the medial superior olive, because this nucleus is missing in most echolocating bats, but appears to be present in the mustache bat, and (2) to the intermediate and ventral nuclei of the lateral lemniscus, because these nuclei are hypertrophied and highly differentiated in all echolocating bats that we have examined. The results show a highly systematic projection from the anteroventral cochlear nucleus to all of the auditory nuclei in the brain stem. After an injection of [ 3 H]-leucine in the anterior and dorsal part of the anteroventral cochlear nucleus, presumably in a region sensitive to low frequencies, label is seen in the following locations: ipsilateral to the injection in the lateral part of the lateral superior olive; bilaterally in the dorsal part of the medial superior olive; contralateral to the injection in the dorsal parts of the intermediate and ventral nuclei of the lateral lemniscus; and in the anterolateral part of the central nucleus of the inferior colliculus. After an injection of [ 3 H]-leucine in a posterior part of the anteroventral cochlear nucleus, presumably in a region sensitive to high frequencies, labeling is in the same set of nuclei, but within each nucleus the label is now in a different location. Projections from the entire anteroventral cochlear nucleus to the inferior colliculus are confined to the ventral two-thirds of the central nucleus

  8. Hearing Preservation Outcomes With a Mid-Scala Electrode in Cochlear Implantation.

    Science.gov (United States)

    Hunter, Jacob B; Gifford, René H; Wanna, George B; Labadie, Robert F; Bennett, Marc L; Haynes, David S; Rivas, Alejandro

    2016-03-01

    To evaluate hearing preservation (HP) outcomes in adult cochlear implant recipients with a mid-scala electrode. Tertiary academic center. Adult patients implanted with a mid-scala electrode between May 2013 and July 2015. Cochlear implantation. Age, sex, surgical approach, residual hearing changes post cochlear implantation, HP rates using different published classifications, and speech perception scores. Fifty ears for 47 patients (mean age, 58.2 yr; range, 23-86) were implanted with the electrode. Recognizing that not all patients were true HP candidates and/or underwent generally accepted HP surgical techniques, 39 ears had preoperative low-frequency hearing (audiometric threshold ≤ 85dB HL at 250Hz), 24 preserved acoustic hearing postoperatively (75.0%). Patients who had preserved acoustic hearing were implanted via round window (N = 18), extended round window (N = 4), or via cochleostomy (N = 2) approaches. Mean threshold elevation for low-frequency pure-tone average (125, 250, and 500  Hz) was 20.2  dB after surgery. 43.8% of patients had aidable low-frequency hearing at activation, 30.0% at 6-months postoperatively, and 30.8% 1-year postopera tively. Using a formula outlined by Skarzynski and colleagues, at 6-months postoperatively, 15.0% of patients had complete HP, whereas 40.0% had partial HP. At 1-year, these percentages decreased to 0% and 38.5%, respectively. Age, type of approach, and perioperative steroid use were not correlated with HP outcomes at activation and 6-months postoperatively (p > 0.05). The mid-scala electrode evaluated allows preservation of low-frequency hearing in patients undergoing cochlear implantation at rates and degrees of preservation close to other reports in the cochlear implant literature.

  9. Productivity of lexical categories in French-speaking children with cochlear implants.

    Science.gov (United States)

    Le Normand, M-T; Ouellet, C; Cohen, H

    2003-11-01

    The productivity of lexical categories was studied longitudinally in a sample of 17 young hearing-impaired French-speaking children with cochlear implants. Age of implantation ranged from 22 months to 76 months. Spontaneous speech samples were collected at six-month intervals over a period of 36 months, starting at the one-word stage. Four general measures of their linguistic production (number of utterances, verbal fluency, vocabulary, and grammatical production) as well as 36 specific lexical categories, according to the CHILDES codes, were computed in terms of tokens, i.e., total number of words. Cochlear-implanted children (CI) were compared to a French database of normally hearing children aged 2-4 compiled by the first author. Follow-up results indicate that, at the two-year post-implantation follow-up, noun, and verb morphology was significantly impaired. At the three-year follow-up, the cochlear-implanted group had recovered on adjectives, determiners and nouns, main verbs, and auxiliaries. The two groups differed significantly in processing locative adverbs, prepositions, pronouns, and verbs (infinitive verb, modal, and modal lexical), but individual variability within the cochlear-implanted group was substantial. Results are discussed in terms of recovery and developmental trends and variability in the acquisition of lexical categories by French children two years and three years post-implantation.

  10. Cochlear implantation in patient with Dandy-walker syndrome.

    Science.gov (United States)

    de Oliveira, Adriana Kosma Pires; Hamerschmidt, Rogerio; Mocelin, Marcos; Rezende, Rodrigo K

    2012-07-01

     Dandy Walker Syndrome is a congenital abnormality in the central nervous system, characterized by a deficiency in the development of middle cerebelar structures, cystic dilatation of the posterior pit communicating with the fourth ventricle and upward shift of the transverse sinuses, tentorium and dyes. Among the clinical signs are occipital protuberances, a progressive increase of the skull, bowing before the fontanels, papilledema, ataxia, gait disturbances, nystagmus, and intellectual impairment.  To describe a case of female patient, 13 years old with a diagnosis of this syndrome and bilateral hearing loss underwent cochlear implant surgery under local anesthesia and sedation.  CGS, 13 years old female was referred to the Otolaryngological Department of Otolaryngology Institute of Parana with a diagnosis of "Dandy-Walker syndrome" for Otolaryngological evaluation for bilateral hearing loss with no response to the use of hearing aids. Final Comments: The field of cochlear implants is growing rapidly. We believe that the presence of Dandy-Walker syndrome cannot be considered a contraindication to the performance of cochlear implant surgery, and there were no surgical complications due to neurological disorders with very favorable results for the patient who exhibits excellent discrimination. It has less need for lip reading with improvement in speech quality.

  11. Cochlear implantation in patient with Dandy-walker syndrome

    Directory of Open Access Journals (Sweden)

    Oliveira, Adriana Kosma Pires de

    2012-01-01

    Full Text Available Introduction: Dandy Walker Syndrome is a congenital abnormality in the central nervous system, characterized by a deficiency in the development of middle cerebelar structures, cystic dilatation of the posterior pit communicating with the fourth ventricle and upward shift of the transverse sinuses, tentorium and dyes. Among the clinical signs are occipital protuberances, a progressive increase of the skull, bowing before the fontanels, papilledema, ataxia, gait disturbances, nystagmus, and intellectual impairment. Objectives: To describe a case of female patient, 13 years old with a diagnosis of this syndrome and bilateral hearing loss underwent cochlear implant surgery under local anesthesia and sedation. Case Report: CGS, 13 years old female was referred to the Otolaryngological Department of Otolaryngology Institute of Parana with a diagnosis of "Dandy-Walker syndrome" for Otolaryngological evaluation for bilateral hearing loss with no response to the use of hearing aids. Final Comments: The field of cochlear implants is growing rapidly. We believe that the presence of Dandy-Walker syndrome cannot be considered a contraindication to the performance of cochlear implant surgery, and there were no surgical complications due to neurological disorders with very favorable results for the patient who exhibits excellent discrimination. It has less need for lip reading with improvement in speech quality.

  12. External laryngeal nerve in thyroid surgery: is the nerve stimulator necessary?

    Science.gov (United States)

    Aina, E N; Hisham, A N

    2001-09-01

    To find out the incidence and type of external laryngeal nerves during operations on the thyroid, and to assess the role of a nerve stimulator in detecting them. Prospective, non-randomised study. Teaching hospital, Malaysia. 317 patients who had 447 dissections between early January 1998 and late November 1999. Number and type of nerves crossing the cricothyroid space, and the usefulness of the nerve stimulator in finding them. The nerve stimulator was used in 206/447 dissections (46%). 392 external laryngeal nerves were seen (88%), of which 196/206 (95%) were detected with the stimulator. However, without the stimulator 196 nerves were detected out of 241 dissections (81%). The stimulator detected 47 (23%) Type I nerves (nerve > 1 cm from the upper edge of superior pole); 86 (42%) Type IIa nerves (nerve edge of superior pole); and 63 (31%) Type IIb nerves (nerve below upper edge of superior pole). 10 nerves were not detected. When the stimulator was not used the corresponding figures were 32 (13%), 113 (47%), and 51 (21%), and 45 nerves were not seen. If the nerve cannot be found we recommend dissection of capsule close to the medial border of the upper pole of the thyroid to avoid injury to the nerve. Although the use of the nerve stimulator seems desirable, it confers no added advantage in finding the nerve. In the event of uncertainty about whether a structure is the nerve, the stimulator may help to confirm it. However, exposure of the cricothyroid space is most important for good exposure in searching for the external laryngeal nerve.

  13. Forward Masking in Cochlear Implant Users: Electrophysiological and Psychophysical Data Using Pulse Train Maskers.

    Science.gov (United States)

    Adel, Youssef; Hilkhuysen, Gaston; Noreña, Arnaud; Cazals, Yves; Roman, Stéphane; Macherey, Olivier

    2017-06-01

    Electrical stimulation of auditory nerve fibers using cochlear implants (CI) shows psychophysical forward masking (pFM) up to several hundreds of milliseconds. By contrast, recovery of electrically evoked compound action potentials (eCAPs) from forward masking (eFM) was shown to be more rapid, with time constants no greater than a few milliseconds. These discrepancies suggested two main contributors to pFM: a rapid-recovery process due to refractory properties of the auditory nerve and a slow-recovery process arising from more central structures. In the present study, we investigate whether the use of different maskers between eCAP and psychophysical measures, specifically single-pulse versus pulse train maskers, may have been a source of confound.In experiment 1, we measured eFM using the following: a single-pulse masker, a 300-ms low-rate pulse train masker (LTM, 250 pps), and a 300-ms high-rate pulse train masker (HTM, 5000 pps). The maskers were presented either at same physical current (Φ) or at same perceptual (Ψ) level corresponding to comfortable loudness. Responses to a single-pulse probe were measured for masker-probe intervals ranging from 1 to 512 ms. Recovery from masking was much slower for pulse trains than for the single-pulse masker. When presented at Φ level, HTM produced more and longer-lasting masking than LTM. However, results were inconsistent when LTM and HTM were compared at Ψ level. In experiment 2, masked detection thresholds of single-pulse probes were measured using the same pulse train masker conditions. In line with our eFM findings, masked thresholds for HTM were higher than those for LTM at Φ level. However, the opposite result was found when the pulse trains were presented at Ψ level.Our results confirm the presence of slow-recovery phenomena at the level of the auditory nerve in CI users, as previously shown in animal studies. Inconsistencies between eFM and pFM results, despite using the same masking conditions, further

  14. Audiological findings after multichannel cochlear implantation in patients with Mondini dysplasia.

    Science.gov (United States)

    Munro, K J; George, C R; Haacke, N P

    1996-12-01

    Mondini dysplasia is a congenital malformation of the inner ear. To date, five individuals with this malformation have received cochlear implants at the South of England Cochlear Implant Centre. The aim of this study was to review the audiological findings of these individuals after implantation. The soundfield thresholds after implantation are in the region of 30-40 dB (A). The results of suprathreshold speech recognition tasks show substantial variability in performance but this is no greater than that obtained from implant users with no malformation. All individuals were able to detect and recognize a variety of environmental sounds that would previously have been inaudible. These findings, along with the reported improvement in quality of life, mean that Mondini dysplasia is not a contra-indication for multichannel cochlear implantation. This information will be useful to other centres when considering implantation in similar patients.

  15. Use of a single bipolar electrode in the posterior arytenoid muscles for bilateral monitoring of the recurrent laryngeal nerves in thyroid surgery.

    Science.gov (United States)

    Haerle, Stephan; Sidler, D; Linder, Th; Mueller, W

    2008-12-01

    The aims were to assess the technical feasibility of using a single electrode in the posterior arytenoid muscles (PAM) for intraoperative monitoring of the recurrent laryngeal nerve (RLN) in thyroid surgery, to validate the new method against the insertion of electrodes placed in the vocal cord muscle, and to report the results of the clinical application of the new concept. A total of 52 patients were enrolled. The handling and safety of RLN monitoring was tested by simultaneous registration of the EMG response from vocal fold electrodes and PAM electrodes. Acoustically and electromyographically we found nearly the same values for the arytenoid muscles as for the vocal folds, although the signals taken from the vocal folds were slightly stronger. PAM recording using a single bipolar electrode is technically feasible and as reliable compared to the standard vocal cord monitoring.

  16. Motor evoked potential monitoring of the vagus nerve with transcranial electrical stimulation during skull base surgeries.

    Science.gov (United States)

    Ito, Eiji; Ichikawa, Masahiro; Itakura, Takeshi; Ando, Hitoshi; Matsumoto, Yuka; Oda, Keiko; Sato, Taku; Watanabe, Tadashi; Sakuma, Jun; Saito, Kiyoshi

    2013-01-01

    Dysphasia is one of the most serious complications of skull base surgeries and results from damage to the brainstem and/or cranial nerves involved in swallowing. Here, the authors propose a method to monitor the function of the vagus nerve using endotracheal tube surface electrodes and transcranial electrical stimulation during skull base surgeries. Fifteen patients with skull base or brainstem tumors were enrolled. The authors used surface electrodes of an endotracheal tube to record compound electromyographic responses from the vocalis muscle. Motor neurons were stimulated using corkscrew electrodes placed subdermally on the scalp at C3 and C4. During surgery, the operator received a warning when the amplitude of the vagal motor evoked potential (MEP) decreased to less than 50% of the control level. After surgery, swallowing function was assessed clinically using grading criteria. In 5 patients, vagal MEP amplitude permanently deteriorated to less than 50% of the control level on the right side when meningiomas were dissected from the pons or basilar artery, or when a schwannoma was dissected from the vagal rootlets. These 5 patients had postoperative dysphagia. At 4 weeks after surgery, 2 patients still had dysphagia. In 2 patients, vagal MEPs of one side transiently disappeared when the tumors were dissected from the brainstem or the vagal rootlets. After surgery, both patients had dysphagia, which recovered in 4 weeks. In 7 patients, MEP amplitude was consistent, maintaining more than 50% of the control level throughout the operative procedures. After surgery all 7 patients were neurologically intact with normal swallowing function. Vagal MEP monitoring with transcranial electrical stimulation and endotracheal tube electrode recording was a safe and effective method to provide continuous real-time information on the integrity of both the supranuclear and infranuclear vagal pathway. This method is useful to prevent intraoperative injury of the brainstem

  17. Chitin biological absorbable catheters bridging sural nerve grafts transplanted into sciatic nerve defects promote nerve regeneration.

    Science.gov (United States)

    Wang, Zhi-Yong; Wang, Jian-Wei; Qin, Li-Hua; Zhang, Wei-Guang; Zhang, Pei-Xun; Jiang, Bao-Guo

    2018-06-01

    To investigate the efficacy of chitin biological absorbable catheters in a rat model of autologous nerve transplantation. A segment of sciatic nerve was removed to produce a sciatic nerve defect, and the sural nerve was cut from the ipsilateral leg and used as a graft to bridge the defect, with or without use of a chitin biological absorbable catheter surrounding the graft. The number and morphology of regenerating myelinated fibers, nerve conduction velocity, nerve function index, triceps surae muscle morphology, and sensory function were evaluated at 9 and 12 months after surgery. All of the above parameters were improved in rats in which the nerve graft was bridged with chitin biological absorbable catheters compared with rats without catheters. The results of this study indicate that use of chitin biological absorbable catheters to surround sural nerve grafts bridging sciatic nerve defects promotes recovery of structural, motor, and sensory function and improves muscle fiber morphology. © 2018 John Wiley & Sons Ltd.

  18. A novel method of lengthening the accessory nerve for direct coaptation during nerve repair and nerve transfer procedures.

    Science.gov (United States)

    Tubbs, R Shane; Maldonado, Andrés A; Stoves, Yolanda; Fries, Fabian N; Li, Rong; Loukas, Marios; Oskouian, Rod J; Spinner, Robert J

    2018-01-01

    OBJECTIVE The accessory nerve is frequently repaired or used for nerve transfer. The length of accessory nerve available is often insufficient or marginal (under tension) for allowing direct coaptation during nerve repair or nerve transfer (neurotization), necessitating an interpositional graft. An attractive maneuver would facilitate lengthening of the accessory nerve for direct coaptation. The aim of the present study was to identify an anatomical method for such lengthening. METHODS In 20 adult cadavers, the C-2 or C-3 connections to the accessory nerve were identified medial to the sternocleidomastoid (SCM) muscle and the anatomy of the accessory nerve/cervical nerve fibers within the SCM was documented. The cervical nerve connections were cut. Lengths of the accessory nerve were measured. Samples of the cut C-2 and C-3 nerves were examined using immunohistochemistry. RESULTS The anatomy and adjacent neural connections within the SCM are complicated. However, after the accessory nerve was "detethered" from within the SCM and following transection, the additional length of the accessory nerve increased from a mean of 6 cm to a mean of 10.5 cm (increase of 4.5 cm) after cutting the C-2 connections, and from a mean of 6 cm to a mean length of 9 cm (increase of 3.5 cm) after cutting the C-3 connections. The additional length of accessory nerve even allowed direct repair of an infraclavicular target (i.e., the proximal musculocutaneous nerve). The cervical nerve connections were shown not to contain motor fibers. CONCLUSIONS An additional length of the accessory nerve made available in the posterior cervical triangle can facilitate direct repair or neurotization procedures, thus eliminating the need for an interpositional nerve graft, decreasing the time/distance for regeneration and potentially improving clinical outcomes.

  19. Influence of hearing age and understanding verbal instructions in children with cochlear implants

    Directory of Open Access Journals (Sweden)

    Đoković Sanja

    2013-01-01

    Full Text Available Hearing age is defined as a period of using any amplification. Most researches indicate that hearing age influences the developmental rate of auditory and speech-language abilities in deaf children, especially when cochlear implantation was performed before the age of three. This research is aimed at analyzing the influence of hearing age on understanding verbal instructions in children with cochlear implants. The sample consists of 23 children with cochlear implants and 21 children with normal hearing, aged between 4 and 10. Hearing age of children with cochlear implants was between 2 and 7 years. Token Test with toys, adapted for children with hearing impairments, was used to analyze understanding verbal instructions. The results indicate that there are statistically significant differences between children with cochlear implants and children with normal hearing, aged between 4 and 7, on all subtests and the total score regardless of the hearing age (sub1 p<0.001, sub2 p<0.000, sub3 p<0.001, total score p<0.000. No statistically significant differences were determined on any of the subtests in children aged between 7.1 and 10, regardless of the hearing age. Comparative results analysis within the experimental group of children with different hearing age indicates that the difference in understanding verbal instructions between these two groups is not statistically significant.

  20. Removal of vestibular schwannoma and facial nerve preservation using small suboccipital retrosigmoid craniotomy

    Institute of Scientific and Technical Information of China (English)

    CHEN Ling; CHEN Li-hua; LING Feng; LIU Yun-sheng; Madjid Samii; Amir Samii

    2010-01-01

    Background Vestibular schwannoma, the commonest form of intracranial schwannoma, arises from the Schwann cells investing the vestibular nerve. At present, the surgery for vestibular schwannoma remains one of the most complicated operations demanding for surgical skills in neurosurgery. And the trend of minimal invasion should also be the major influence on the management of patients with vestibular schwannomas. We summarized the microsurgical removal experience in a recent series of vestibular schwannomas and presented the operative technique and cranial nerve preservation in order to improve the rates of total tumor removal and facial nerve preservation.Methods A retrospective analysis was performed in 145 patients over a 7-year period who suffered from vestibular schwannomas that had been microsurgicaily removed by suboccipital retrosigmoid transmeatus approach with small craniotomy. CT thinner scans revealed the tumor size in the internal auditory meatus and the relationship of the posterior wall of the internal acoustic meatus to the bone labyrinths preoperatively. Brain stem evoked potential was monitored intraoperatively. The posterior wall of the internal acoustic meatus was designedly drilled off. Patient records and operative reports, including data from the electrophysiological monitoring, follow-up audiometric examinations, and neuroradiological findings were analyzed.Results Total tumor resection was achieved in 140 cases (96.6%) and subtotal resection in 5 cases. The anatomical integrity of the facial nerve was preserved in 91.0% (132/145) of the cases. Intracranial end-to-end anastomosis of the facial nerve was performed in 7 cases. Functional preservation of the facial nerve was achieved in 115 patients (Grade Ⅰ and Grade Ⅱ, 79.3%). No patient died in this series. Preservation of nerves and vessels were as important as tumor removal dudng the operation. CT thinner scan could show the relationship between the posterior wall of the internal

  1. Hypoglossal-facial-jump-anastomosis without an interposition nerve graft.

    Science.gov (United States)

    Beutner, Dirk; Luers, Jan C; Grosheva, Maria

    2013-10-01

    The hypoglossal-facial-anastomosis is the most often applied procedure for the reanimation of a long lasting peripheral facial nerve paralysis. The use of an interposition graft and its end-to-side anastomosis to the hypoglossal nerve allows the preservation of the tongue function and also requires two anastomosis sites and a free second donor nerve. We describe the modified technique of the hypoglossal-facial-jump-anastomosis without an interposition and present the first results. Retrospective case study. We performed the facial nerve reconstruction in five patients. The indication for the surgery was a long-standing facial paralysis with preserved portion distal to geniculate ganglion, absent voluntary activity in the needle facial electromyography, and an intact bilateral hypoglossal nerve. Following mastoidectomy, the facial nerve was mobilized in the fallopian canal down to its bifurcation in the parotid gland and cut in its tympanic portion distal to the lesion. Then, a tensionless end-to-side suture to the hypoglossal nerve was performed. The facial function was monitored up to 16 months postoperatively. The reconstruction technique succeeded in all patients: The facial function improved within the average time period of 10 months to the House-Brackmann score 3. This modified technique of the hypoglossal-facial reanimation is a valid method with good clinical results, especially in cases of a preserved intramastoidal facial nerve. Level 4. Copyright © 2013 The American Laryngological, Rhinological and Otological Society, Inc.

  2. Hearing experience and receptive vocabulary development in deaf children with cochlear implants.

    Science.gov (United States)

    Fagan, Mary K; Pisoni, David B

    2010-01-01

    This study investigated receptive vocabulary delay in deaf children with cochlear implants. Participants were 23 children with profound hearing loss, ages 6-14 years, who received a cochlear implant between ages 1.4 and 6 years. Duration of cochlear implant use ranged from 3.7 to 11.8 years. Peabody Picture Vocabulary Test, Third Edition (PPVT-III) data were analyzed first by examining children's errors for evidence of difficulty in specific lexical content areas, and second by calculating standard scores with reference to hearing age (HA) (i.e., chronological age [CA]--age at implantation) rather than CA. Participants showed evidence of vocabulary understanding across all PPVT-III content categories with no strong evidence of disproportionate numbers of errors in any specific content area despite below-average mean standard scores. However, whereas mean standard scores were below the test mean established for hearing children when based on CA, they were within the average range for hearing children when calculated based on HA. Thus, children's vocabulary knowledge was commensurate with years of cochlear implant experience, providing support for the role of spoken language experience in vocabulary acquisition.

  3. Cochlear implant: the family's perspective.

    Science.gov (United States)

    Vieira, Sheila de Souza; Dupas, Giselle; Chiari, Brasilia Maria

    2018-07-01

    To understand the family's experience of a child who uses a cochlear implant (CI). Specifically, to identify the difficulties, changes, and feelings entailed by deafness and the use of the CI; the coping strategies; and to understand the role of the family for the child with a CI. Qualitative research, using Symbolic Interactionism and Straussian Grounded Theory as the theoretical and methodological frameworks, respectively. Data collection instrument: semi-structured interview. A total of 9 families (32 individuals) participated in the study. The children's ages ranged from 6 to 11 years old (mean = 8.9 years old). Their experience is described in the following categories: Having to fight for results, Coping with difficult situations, Recognizing that you are not alone, Learning to overcome, and Having one's life restored by the implant. Cochlear implantation changes the direction of the child and the family's life by restoring the child's opportunity to hear and to obtain good results in her personal, social, and academic development. Even after implantation, the child continues to experience difficulties and requires the family's mobilization in order to be successful. The family is the principal actor in the process of the child's rehabilitation.

  4. The comparison of balance performance among children with cochlear implantation, post-aural aid and normal children

    Directory of Open Access Journals (Sweden)

    Arezoo Ahmad pour

    2014-11-01

    Full Text Available Background: This cross-sectional study was carried out to compare balance performance between children with cochlear implants and post-aural aid and normal children. Methods: The present study was done on 67 severe to profound hearing impaired children. Of these, 21 children with an average age of 7 years and 4 months (±1.7 wore cochlear implant, 46 children with an average age of 7 years and 7 months (±1.7 wore post-aural aid and 60 children with an average 8 years and one month (±11 months were considered as a control group. All of the children were tested with the 9-stage balance subtest of Bruininks-Oseretsky Test of Motor Proficiency2 (BOT2. Results: The mean total BOT2 score of hearing impaired children was significantly lower than the normal group (P≤0.001. The mean total BOT2 score among children with cochlear implant, post-aural aids and normal group showed that cochlear implant group significantly performed weaker than the other two groups (P≤0.001. Conclusion: Hearing impaired children particularly children with cochlear implant are exposed to the risk of balance deficit. Hearing impaired children specially those who wear cochlear implants must be screened for vestibular hypofunction.

  5. Dislocation of cochlear implant magnet as a complication following MRI.

    Science.gov (United States)

    Murtojärvi, Sarita; Salonen, Jaakko

    According to current best knowledge, an MRI scan can be performed for patients with cochlear implants. The warnings and recommendations of the implant manufacturers must be followed strictly to prevent complications, such as overheating, migration or demagnetization of the magnet in the implant. We report on a case of cochlear implant magnet dislocation as a complication for an MRI scan. The patient had a tight bandage around the head to hold the magnet in place as recommended by the manufacturer, but apparently the bandage was not in the correct place.

  6. Nanofiber Nerve Guide for Peripheral Nerve Repair and Regeneration

    Science.gov (United States)

    2016-04-01

    1 Award Number: W81XWH-11-2-0047 TITLE: Nanofiber Nerve Guide for Peripheral Nerve Repair and Regeneration PRINCIPAL INVESTIGATOR: Ahmet Höke...TITLE AND SUBTITLE 5a. CONTRACT NUMBER W81XWH-11-2-0047 Nanofiber nerve guide for peripheral nerve repair and regeneration 5b. GRANT NUMBER...goal of this collaborative research project was to develop next generation engineered nerve guide conduits (NGCs) with aligned nanofibers and

  7. Continued expression of GATA3 is necessary for cochlear neurosensory development.

    Directory of Open Access Journals (Sweden)

    Jeremy S Duncan

    Full Text Available Hair cells of the developing mammalian inner ear are progressively defined through cell fate restriction. This process culminates in the expression of the bHLH transcription factor Atoh1, which is necessary for differentiation of hair cells, but not for their specification. Loss of several genes will disrupt ear morphogenesis or arrest of neurosensory epithelia development. We previously showed in null mutants that the loss of the transcription factor, Gata3, results specifically in the loss of all cochlear neurosensory development. Temporal expression of Gata3 is broad from the otic placode stage through the postnatal ear. It therefore remains unclear at which stage in development Gata3 exerts its effect. To better understand the stage specific effects of Gata3, we investigated the role of Gata3 in cochlear neurosensory specification and differentiation utilizing a LoxP targeted Gata3 line and two Cre lines. Foxg1(Cre∶Gata3(f/f mice show recombination of Gata3 around E8.5 but continue to develop a cochlear duct without differentiated hair cells and spiral ganglion neurons. qRT-PCR data show that Atoh1 was down-regulated but not absent in the duct whereas other hair cell specific genes such as Pou4f3 were completely absent. In addition, while Sox2 levels were lower in the Foxg1(Cre:Gata3(f/f cochlea, Eya1 levels remained normal. We conclude that Eya1 is unable to fully upregulate Atoh1 or Pou4f3, and drive differentiation of hair cells without Gata3. Pax2-Cre∶Gata3(f/f mice show a delayed recombination of Gata3 in the ear relative to Foxg1(Cre:Gata3(f/f . These mice exhibited a cochlear duct containing patches of partially differentiated hair cells and developed only few and incorrectly projecting spiral ganglion neurons. Our conditional deletion studies reveal a major role of Gata3 in the signaling of prosensory genes and in the differentiation of cochlear neurosenory cells. We suggest that Gata3 may act in combination with Eya1, Six1, and

  8. Cochlear implant benefits in deafness rehabilitation: PET study of temporal voice Activations

    Energy Technology Data Exchange (ETDEWEB)

    Coez, A.; Zilbovicius, M. [CEA, Serv Hosp Frederic Joliot, INSERM, Res Unit Neuroimaging and Psychiat, U797, IFR49, F-91406 Orsay (France); Zilbovicius, M.; Syrota, A.; Samson, Y. [CEA, DSV, DRM, Serv Hosp Frederic Joliot, F-91406 Orsay (France); Bizaguet, E. [Lab Correct Audit, Paris (France); Coez, A. [Univ Paris Sud 11, Paris (France); Ferrary, E.; Bouccara, D.; Mosnier, I.; Sterkers, O. [INSERM, Unit M 867, Paris (France); Ambert-Dahan, E. [Hop Beaujon, Serv ORL Chirurg Cervicofaciale, AP-HP, Clichy (France); Ferrary, E.; Bouccara, D.; Mosnier, I.; Sterkers, O. [Inst Fed Rech Claude Bernard Physiol et Pathol, IFR02, Paris (France); Samson, Y. [Hop La Pitie Salpetriere, Serv Urgences Cerebro-vasc, AP-HP, Paris (France); Samson, Y. [Univ Paris 06, Paris (France); Sterkers, O. [Univ Denis Diderot Paris 7, Paris (France)

    2008-07-01

    Cochlear implants may improve the medical and social prognosis of profound deafness. Nevertheless, some patients have experienced poor results without any clear explanations. One correlate may be an alteration in cortical voice processing. To test this hypothesis, we studied the activation of human temporal voice areas (TVA) using a well-standardized PET paradigm adapted from previous functional MRI (fMRI) studies. Methods: A PET H{sub 2}{sup 15}O activation study was performed on 3 groups of adult volunteers: normal-hearing control subjects (n 6) and cochlear-implanted post-lingually deaf patients with {>=}2 y of cochlear implant experience, with intelligibility scores in the 'Lafon monosyllabic task' {>=}80% (Good group; n 6) or {<=}20% (Poor group; n 6). Relative cerebral blood flow was measured in 3 conditions: rest, passive listening to human voice, and non-voice stimuli. Results: Compared with silence, the activations induced by non-voice stimuli were bilaterally located in the superior temporal regions in all groups. However these activations were significantly and similarly reduced in both cochlear implant groups, whereas control subjects showed supplementary activations. Compared with non-voice, the voice stimuli induced bilateral activation of the TVA along the superior temporal sulcus (STS) in both the control and the Good groups. In contrast, these activations were not detected in the Poor group, which showed only left unilateral middle STS activation. Conclusion: These results suggest that PET is an adequate method to explore cochlear implant benefits and that this benefit could be linked to the activation of the TVA. (authors)

  9. Cochlear implant benefits in deafness rehabilitation: PET study of temporal voice Activations

    International Nuclear Information System (INIS)

    Coez, A.; Zilbovicius, M.; Zilbovicius, M.; Syrota, A.; Samson, Y.; Bizaguet, E.; Coez, A.; Ferrary, E.; Bouccara, D.; Mosnier, I.; Sterkers, O.; Ambert-Dahan, E.; Ferrary, E.; Bouccara, D.; Mosnier, I.; Sterkers, O.; Samson, Y.; Samson, Y.; Sterkers, O.

    2008-01-01

    Cochlear implants may improve the medical and social prognosis of profound deafness. Nevertheless, some patients have experienced poor results without any clear explanations. One correlate may be an alteration in cortical voice processing. To test this hypothesis, we studied the activation of human temporal voice areas (TVA) using a well-standardized PET paradigm adapted from previous functional MRI (fMRI) studies. Methods: A PET H 2 15 O activation study was performed on 3 groups of adult volunteers: normal-hearing control subjects (n 6) and cochlear-implanted post-lingually deaf patients with ≥2 y of cochlear implant experience, with intelligibility scores in the 'Lafon monosyllabic task' ≥80% (Good group; n 6) or ≤20% (Poor group; n 6). Relative cerebral blood flow was measured in 3 conditions: rest, passive listening to human voice, and non-voice stimuli. Results: Compared with silence, the activations induced by non-voice stimuli were bilaterally located in the superior temporal regions in all groups. However these activations were significantly and similarly reduced in both cochlear implant groups, whereas control subjects showed supplementary activations. Compared with non-voice, the voice stimuli induced bilateral activation of the TVA along the superior temporal sulcus (STS) in both the control and the Good groups. In contrast, these activations were not detected in the Poor group, which showed only left unilateral middle STS activation. Conclusion: These results suggest that PET is an adequate method to explore cochlear implant benefits and that this benefit could be linked to the activation of the TVA. (authors)

  10. Establishment of Peripheral Nerve Injury Data Repository to Monitor and Support Population Health Decisions

    Science.gov (United States)

    2017-07-01

    Military Medical Center (WRNMMC) for Peripheral Nerve Injury (PNI) treatment. A database , the Peripheral Nerve Injury Database (PNIDB), will be established...to catalog and describe the characteristics, mechanisms, management, and outcomes of PNIs using both retrospective chart review and prospective...decisions for patients with PNIs. These outcomes could be used in future study to further characterize PNIs and delineate which management

  11. Cochlear function tests in estimation of speech dynamic range.

    Science.gov (United States)

    Han, Jung Ju; Park, So Young; Park, Shi Nae; Na, Mi Sun; Lee, Philip; Han, Jae Sang

    2016-10-01

    The loss of active cochlear mechanics causes elevated thresholds, loudness recruitment, and reduced frequency selectivity. The problems faced by hearing-impaired listeners are largely related with reduced dynamic range (DR). The aim of this study was to determine which index of the cochlear function tests correlates best with the DR to speech stimuli. Audiological data on 516 ears with pure tone average (PTA) of ≤55 dB and word recognition score of ≥70% were analyzed. PTA, speech recognition threshold (SRT), uncomfortable loudness (UCL), and distortion product otoacoustic emission (DPOAE) were explored as the indices of cochlear function. Audiometric configurations were classified. Correlation between each index and the DR was assessed and multiple regression analysis was done. PTA and SRT demonstrated strong negative correlations with the DR (r = -0.788 and -0.860, respectively), while DPOAE sum was moderately correlated (r = 0.587). UCLs remained quite constant for the total range of the DR. The regression equation was Y (DR) = 75.238 - 0.719 × SRT (R(2 )=( )0.721, p equation.

  12. Radial nerve dysfunction

    Science.gov (United States)

    Neuropathy - radial nerve; Radial nerve palsy; Mononeuropathy ... Damage to one nerve group, such as the radial nerve, is called mononeuropathy . Mononeuropathy means there is damage to a single nerve. Both ...

  13. Malignant peripheral nerve sheath tumor of the oculomotor nerve

    DEFF Research Database (Denmark)

    Kozic, D; Nagulic, M; Ostojic, J

    2006-01-01

    We present the short-term follow-up magnetic resonance (MR) studies and 1H-MR spectroscopy in a child with malignant peripheral nerve sheath tumor of the oculomotor nerve associated with other less aggressive cranial nerve schwannomas. The tumor revealed perineural extension and diffuse nerve...

  14. Scaffoldless tissue-engineered nerve conduit promotes peripheral nerve regeneration and functional recovery after tibial nerve injury in rats

    Institute of Scientific and Technical Information of China (English)

    Aaron M. Adams; Keith W. VanDusen; Tatiana Y. Kostrominova; Jacob P. Mertens; Lisa M. Larkin

    2017-01-01

    Damage to peripheral nerve tissue may cause loss of function in both the nerve and the targeted muscles it innervates. This study compared the repair capability of engineered nerve conduit (ENC), engineered fibroblast conduit (EFC), and autograft in a 10-mm tibial nerve gap. ENCs were fabricated utilizing primary fibroblasts and the nerve cells of rats on embryonic day 15 (E15). EFCs were fabricated utilizing primary fi-broblasts only. Following a 12-week recovery, nerve repair was assessed by measuring contractile properties in the medial gastrocnemius muscle, distal motor nerve conduction velocity in the lateral gastrocnemius, and histology of muscle and nerve. The autografts, ENCs and EFCs reestablished 96%, 87% and 84% of native distal motor nerve conduction velocity in the lateral gastrocnemius, 100%, 44% and 44% of native specific force of medical gastrocnemius, and 63%, 61% and 67% of native medial gastrocnemius mass, re-spectively. Histology of the repaired nerve revealed large axons in the autograft, larger but fewer axons in the ENC repair, and many smaller axons in the EFC repair. Muscle histology revealed similar muscle fiber cross-sectional areas among autograft, ENC and EFC repairs. In conclusion, both ENCs and EFCs promot-ed nerve regeneration in a 10-mm tibial nerve gap repair, suggesting that the E15 rat nerve cells may not be necessary for nerve regeneration, and EFC alone can suffice for peripheral nerve injury repair.

  15. Electroacoustic verification of frequency modulation systems in cochlear implant users.

    Science.gov (United States)

    Fidêncio, Vanessa Luisa Destro; Jacob, Regina Tangerino de Souza; Tanamati, Liége Franzini; Bucuvic, Érika Cristina; Moret, Adriane Lima Mortari

    2017-12-26

    The frequency modulation system is a device that helps to improve speech perception in noise and is considered the most beneficial approach to improve speech recognition in noise in cochlear implant users. According to guidelines, there is a need to perform a check before fitting the frequency modulation system. Although there are recommendations regarding the behavioral tests that should be performed at the fitting of the frequency modulation system to cochlear implant users, there are no published recommendations regarding the electroacoustic test that should be performed. Perform and determine the validity of an electroacoustic verification test for frequency modulation systems coupled to different cochlear implant speech processors. The sample included 40 participants between 5 and 18 year's users of four different models of speech processors. For the electroacoustic evaluation, we used the Audioscan Verifit device with the HA-1 coupler and the listening check devices corresponding to each speech processor model. In cases where the transparency was not achieved, a modification was made in the frequency modulation gain adjustment and we used the Brazilian version of the "Phrases in Noise Test" to evaluate the speech perception in competitive noise. It was observed that there was transparency between the frequency modulation system and the cochlear implant in 85% of the participants evaluated. After adjusting the gain of the frequency modulation receiver in the other participants, the devices showed transparency when the electroacoustic verification test was repeated. It was also observed that patients demonstrated better performance in speech perception in noise after a new adjustment, that is, in these cases; the electroacoustic transparency caused behavioral transparency. The electroacoustic evaluation protocol suggested was effective in evaluation of transparency between the frequency modulation system and the cochlear implant. Performing the adjustment of

  16. Communication between radial nerve and medial cutaneous nerve of forearm

    Directory of Open Access Journals (Sweden)

    R R Marathe

    2010-01-01

    Full Text Available Radial nerve is usually a branch of the posterior cord of the brachial plexus. It innervates triceps, anconeous, brachialis, brachioradialis, extensor carpi radialis longus muscles and gives the posterior cutaneous nerve of the arm, lower lateral cutaneous nerve of arm, posterior cutaneous nerve of forearm; without exhibiting any communication with the medial cutaneous nerve of forearm or any other nerve. We report communication between the radial nerve and medial cutaneous nerve of forearm on the left side in a 58-year-old male cadaver. The right sided structures were found to be normal. Neurosurgeons should keep such variations in mind while performing the surgeries of axilla and upper arm.

  17. A case of improved hearing with cochlear implantation in Gaucher disease type 1.

    Science.gov (United States)

    Endo, Shiori; Mizuta, Kunihiro; Yamatodani, Takashi; Nakanishi, Hiroshi; Hosokawa, Kumiko; Misawa, Kiyoshi; Hosokawa, Seiji; Mineta, Hiroyuki

    2018-06-01

    Gaucher disease is a lysosomal storage disorder that is caused by congenital defective function of the enzyme glucocerebrosidase. Glucocerebroside that is not hydrolyzed by glucocerebrosidase mainly accumulates in the reticular tissue. We describe a Japanese boy with Gaucher disease type 1 who developed bilateral profound sensorineural hearing loss within approximately 4years. We performed cochlear implantation initially on his right ear and again on his left ear 5 months later. The cochlear implants were successfully utilized with a speech discrimination score of 95% on a Japanese sentence recognition test. There are many reports of central hearing loss in Gaucher disease type 2 or 3. However, to the best of our knowledge, this is the first report of profound inner ear hearing loss with Gaucher disease. It also appears to be the first record of cochlear implantation for Gaucher disease. Cochlear implants may be useful for sensorineural hearing loss in patients with Gaucher disease without neurological symptoms other than hearing loss. Copyright © 2017 Elsevier B.V. All rights reserved.

  18. Electrode selection for hearing preservation in cochlear implantation: A review of the evidence

    Directory of Open Access Journals (Sweden)

    Jason A. Brant

    2016-09-01

    Full Text Available Objective: To review and assess the ideal length of electrode in cochlear implant patients for hearing preservation. Methods: The English language literature was reviewed for studies including hearing preservation and speech understanding for electrodes of different lengths. Results: One prospective trial was found, and there were no studies that randomized patients into different length electrodes with an intent to preserve hearing. Eight studies total included multiple length electrodes and contained data regarding hearing preservation. Conclusions: Although there is some evidence that indicates that shorter electrodes may improve both short and long-term hearing preservation rates in cochlear implant patients, no study has directly compared implant length on hearing preservation in a similar patient population. A randomized trial of short and standard length electrodes for hearing preservation is warranted. In the interim, utilization of current electrodes measuring 20–25 mm could seem to be a prudent approach when seeking to preserve residual hearing without unduly compromising cochlear coverage. Keywords: Electrode, Length, Hearing preservation, Cochlear implantation

  19. EEG frontal asymmetry related to pleasantness of music perception in healthy children and cochlear implanted users.

    Science.gov (United States)

    Vecchiato, G; Maglione, A G; Scorpecci, A; Malerba, P; Marsella, P; Di Francesco, G; Vitiello, S; Colosimo, A; Babiloni, Fabio

    2012-01-01

    Interestingly, the international debate about the quality of music fruition for cochlear implanted users does not take into account the hypothesis that bilateral users could perceive music in a more pleasant way with respect to monolateral users. In this scenario, the aim of the present study was to investigate if cerebral signs of pleasantness during music perception in healthy child are similar to those observed in monolateral and in bilateral cochlear implanted users. In fact, previous observations in literature on healthy subjects have indicated that variations of the frontal EEG alpha activity are correlated with the perceived pleasantness of the sensory stimulation received (approach-withdrawal theory). In particular, here we described differences between cortical activities estimated in the alpha frequency band for a healthy child and in patients having a monolateral or a bilateral cochlear implant during the fruition of a musical cartoon. The results of the present analysis showed that the alpha EEG asymmetry patterns observed in a healthy child and that of a bilateral cochlear implanted patient are congruent with the approach-withdrawal theory. Conversely, the scalp topographic distribution of EEG power spectra in the alpha band resulting from the monolateral cochlear user presents a different EEG pattern from the normal and bilateral implanted patients. Such differences could be explained at the light of the approach-withdrawal theory. In fact, the present findings support the hypothesis that a monolateral cochlear implanted user could perceive the music in a less pleasant way when compared to a healthy subject or to a bilateral cochlear user.

  20. Degradation of labial information modifies audiovisual speech perception in cochlear-implanted children.

    Science.gov (United States)

    Huyse, Aurélie; Berthommier, Frédéric; Leybaert, Jacqueline

    2013-01-01

    The aim of the present study was to examine audiovisual speech integration in cochlear-implanted children and in normally hearing children exposed to degraded auditory stimuli. Previous studies have shown that speech perception in cochlear-implanted users is biased toward the visual modality when audition and vision provide conflicting information. Our main question was whether an experimentally designed degradation of the visual speech cue would increase the importance of audition in the response pattern. The impact of auditory proficiency was also investigated. A group of 31 children with cochlear implants and a group of 31 normally hearing children matched for chronological age were recruited. All children with cochlear implants had profound congenital deafness and had used their implants for at least 2 years. Participants had to perform an /aCa/ consonant-identification task in which stimuli were presented randomly in three conditions: auditory only, visual only, and audiovisual (congruent and incongruent McGurk stimuli). In half of the experiment, the visual speech cue was normal; in the other half (visual reduction) a degraded visual signal was presented, aimed at preventing lipreading of good quality. The normally hearing children received a spectrally reduced speech signal (simulating the input delivered by the cochlear implant). First, performance in visual-only and in congruent audiovisual modalities were decreased, showing that the visual reduction technique used here was efficient at degrading lipreading. Second, in the incongruent audiovisual trials, visual reduction led to a major increase in the number of auditory based responses in both groups. Differences between proficient and nonproficient children were found in both groups, with nonproficient children's responses being more visual and less auditory than those of proficient children. Further analysis revealed that differences between visually clear and visually reduced conditions and between

  1. Ulnar nerve dysfunction

    Science.gov (United States)

    Neuropathy - ulnar nerve; Ulnar nerve palsy; Mononeuropathy; Cubital tunnel syndrome ... Damage to one nerve group, such as the ulnar nerve, is called mononeuropathy . Mononeuropathy means there is damage to a single nerve. Both ...

  2. Routes, dynamics, and correlates of cochlear inflammation in terminal and recovering experimental meningitis

    DEFF Research Database (Denmark)

    Cayé-Thomasen, Per; Worsøe, Lise; Brandt, Christian Thomas

    2009-01-01

    OBJECTIVES/HYPOTHESIS: To examine the routes, dynamics and correlates of cochlear inflammation in meningitis to provide information on the pathogenesis of the associated hearing loss and indications for rational pharmacotherapeutical intervention. STUDY DESIGN: A well-established rat model...... with inflammatory cells via cochlear aqueduct, whereas the endolymphatic space was infiltrated from the spiral ligament. Rosenthal's canal was infiltrated through osseous spiral lamina canaliculi. In the untreated group, the degree of inflammation correlated with time of death, whereas antibiotic treatment reversed...... this development. Perilymphatic inflammation correlated significantly with the CSF leukocyte count, whereas endolymphatic inflammation correlated with spiral ligament inflammation. CONCLUSIONS: Meningogenic inflammation of the rat cochlea occurs via the cochlear aqueduct and the spiral ligament capillary bed...

  3. Baseline effects of lysophosphatidylcholine and nerve growth factor in a rat model of sciatic nerve regeneration after crush injury

    Directory of Open Access Journals (Sweden)

    Ryan L Wood

    2018-01-01

    Full Text Available Schwann cells play a major role in helping heal injured nerves. They help clear debris, produce neurotrophins, upregulate neurotrophin receptors, and form bands of Büngner to guide the healing nerve. But nerves do not always produce enough neurotrophins and neurotrophin receptors to repair themselves. Nerve growth factor (NGF is an important neurotrophin for promoting nerve healing and lysophosphatidylcholine (LPC has been shown to stimulate NGF receptors (NGFR. This study tested the administration of a single intraneural injection of LPC (1 mg/mL for single LPC injection and 10 mg/mL for multiple LPC injections at day 0 and one (day 7, two (days 5 and 7, or three (days 5, 7, and 9 injections of NGF (160 ng/mL for single injections and 80 ng/mL for multiple injections to determine baseline effects on crushed sciatic nerves in rats. The rats were randomly divided into four groups: control, crush, crush-NGF, and crush-LPC-NGF. The healing of the nerves was measured weekly by monitoring gait; electrophysiological parameters: compound muscle action potential (CMAP amplitudes; and morphological parameters: total fascicle areas, myelinated fiber counts, fiber densities, fiber packing, and mean g-ratio values at weeks 3 and 6. The crush, crush-NGF, and crush-LPC-NGF groups statistically differed from the control group for all six weeks for the electrophysiological parameters but only differed from the control group at week 3 for the morphological parameters. The crush, crush-NGF, and crush-LPC-NGF groups did not differ from each other over the course of the study. Single injections of LPC and NGF one week apart or multiple treatments of NGF at 5, 7 and 9 days post-injury did not alter the healing rate of the sciatic nerves during weeks 1-6 of the study. These findings are important to define the baseline effects of NGF and LPC injections, as part of a larger effort to determine the minimal dose regimen of NGF to regenerate peripheral nerves.

  4. Predicting social functioning in children with a cochlear implant and in normal-hearing children: the role of emotion regulation.

    Science.gov (United States)

    Wiefferink, Carin H; Rieffe, Carolien; Ketelaar, Lizet; Frijns, Johan H M

    2012-06-01

    The purpose of the present study was to compare children with a cochlear implant and normal hearing children on aspects of emotion regulation (emotion expression and coping strategies) and social functioning (social competence and externalizing behaviors) and the relation between emotion regulation and social functioning. Participants were 69 children with cochlear implants (CI children) and 67 normal hearing children (NH children) aged 1.5-5 years. Parents answered questionnaires about their children's language skills, social functioning, and emotion regulation. Children also completed simple tasks to measure their emotion regulation abilities. Cochlear implant children had fewer adequate emotion regulation strategies and were less socially competent than normal hearing children. The parents of cochlear implant children did not report fewer externalizing behaviors than those of normal hearing children. While social competence in normal hearing children was strongly related to emotion regulation, cochlear implant children regulated their emotions in ways that were unrelated with social competence. On the other hand, emotion regulation explained externalizing behaviors better in cochlear implant children than in normal hearing children. While better language skills were related to higher social competence in both groups, they were related to fewer externalizing behaviors only in cochlear implant children. Our results indicate that cochlear implant children have less adequate emotion-regulation strategies and less social competence than normal hearing children. Since they received their implants relatively recently, they might eventually catch up with their hearing peers. Longitudinal studies should further explore the development of emotion regulation and social functioning in cochlear implant children. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  5. Effect of rocuronium on the level and mode of pre-synaptic acetylcholine release by facial and somatic nerves, and changes following facial nerve injury in rabbits.

    Science.gov (United States)

    Tan, Jinghua; Xu, Jing; Xing, Yian; Chen, Lianhua; Li, Shitong

    2015-01-01

    Muscles innervated by the facial nerve show differential sensitivities to muscle relaxants than muscles innervated by somatic nerves. The evoked electromyography (EEMG) response is also proportionally reduced after facial nerve injury. This forms the theoretical basis for proper utilization of muscle relaxants to balance EEMG monitoring and immobility under general anesthesia. (1) To observe the relationships between the level and mode of acetylcholine (ACh) release and the duration of facial nerve injury, and the influence of rocuronium in an in vitro rabbit model. (2) To explore the pre-synaptic mechanisms of discrepant responses to a muscle relaxant. Quantal and non-quantal ACh release were measured by using intracellular microelectrode recording in the orbicularis oris 1 to 42 days after graded facial nerve injury and in the gastrocnemius with/without rocuronium. Quantal ACh release was significantly decreased by rocuronium in the orbicularis oris and gastrocnemius, but significantly more so in gastrocnemius. Quantal release was reduced after facial nerve injury, which was significantly correlated with the severity of nerve injury in the absence but not in the presence of rocuronium. Non-quantal ACh release was reduced after facial nerve injury, with many relationships observed depending on the extent of the injury. The extent of inhibition of non-quantal release by rocuronium correlated with the grade of facial nerve injury. These findings may explain why EEMG amplitude might be diminished after acute facial nerve injury but relatively preserved after chronic injury and differential responses in sensitivity to rocuronium.

  6. Electrophysiological evidence for altered visual, but not auditory, selective attention in adolescent cochlear implant users.

    Science.gov (United States)

    Harris, Jill; Kamke, Marc R

    2014-11-01

    Selective attention fundamentally alters sensory perception, but little is known about the functioning of attention in individuals who use a cochlear implant. This study aimed to investigate visual and auditory attention in adolescent cochlear implant users. Event related potentials were used to investigate the influence of attention on visual and auditory evoked potentials in six cochlear implant users and age-matched normally-hearing children. Participants were presented with streams of alternating visual and auditory stimuli in an oddball paradigm: each modality contained frequently presented 'standard' and infrequent 'deviant' stimuli. Across different blocks attention was directed to either the visual or auditory modality. For the visual stimuli attention boosted the early N1 potential, but this effect was larger for cochlear implant users. Attention was also associated with a later P3 component for the visual deviant stimulus, but there was no difference between groups in the later attention effects. For the auditory stimuli, attention was associated with a decrease in N1 latency as well as a robust P3 for the deviant tone. Importantly, there was no difference between groups in these auditory attention effects. The results suggest that basic mechanisms of auditory attention are largely normal in children who are proficient cochlear implant users, but that visual attention may be altered. Ultimately, a better understanding of how selective attention influences sensory perception in cochlear implant users will be important for optimising habilitation strategies. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  7. Ethical considerations in resource allocation in a cochlear implant program.

    Science.gov (United States)

    Westerberg, Brian D; Pijl, Sipke; McDonald, Michael

    2008-04-01

    To review processes of resource allocation and the ethical considerations relevant to the fair allocation of a limited number of cochlear implants to increasing numbers of potential recipients. Review of relevant considerations. Tertiary referral hospital. Editorial discussion of the ethical issues of resource allocation. Heterogeneity of audiometric thresholds, self-reported disability of hearing loss, age of the potential cochlear implant recipient, cost-effectiveness, access to resources, compliance with follow-up, social support available to the recipient, social consequences of hearing impairment, and other recipient-related factors. In a publicly funded health care system, there will always be a need for decision-making processes for allocation of finite fiscal resources. All candidates for cochlear implantation deserve fair consideration. However, they are a heterogeneous group in terms of needs and expected outcomes consisting of traditional and marginal candidates, with a wide range of benefit from acoustic amplification. We argue that implant programs should thoughtfully prioritize treatment on the basis of need and potential benefit. We reject queuing on the basis of "first-come, first-served" or on the basis of perceived social worth.

  8. The First Experience of Triple Nerve Transfer in Proximal Radial Nerve Palsy.

    Science.gov (United States)

    Emamhadi, Mohammadreza; Andalib, Sasan

    2018-01-01

    Injury to distal portion of posterior cord of brachial plexus leads to palsy of radial and axillary nerves. Symptoms are usually motor deficits of the deltoid muscle; triceps brachii muscle; and extensor muscles of the wrist, thumb, and fingers. Tendon transfers, nerve grafts, and nerve transfers are options for surgical treatment of proximal radial nerve palsy to restore some motor functions. Tendon transfer is painful, requires a long immobilization, and decreases donor muscle strength; nevertheless, nerve transfer produces promising outcomes. We present a patient with proximal radial nerve palsy following a blunt injury undergoing triple nerve transfer. The patient was involved in a motorcycle accident with complete palsy of the radial and axillary nerves. After 6 months, on admission, he showed spontaneous recovery of axillary nerve palsy, but radial nerve palsy remained. We performed triple nerve transfer, fascicle of ulnar nerve to long head of the triceps branch of radial nerve, flexor digitorum superficialis branch of median nerve to extensor carpi radialis brevis branch of radial nerve, and flexor carpi radialis branch of median nerve to posterior interosseous nerve, for restoration of elbow, wrist, and finger extensions, respectively. Our experience confirmed functional elbow, wrist, and finger extensions in the patient. Triple nerve transfer restores functions of the upper limb in patients with debilitating radial nerve palsy after blunt injuries. Copyright © 2017 Elsevier Inc. All rights reserved.

  9. Standardization of reliability reporting for cochlear implants: an interim report.

    Science.gov (United States)

    Backous, Douglas D; Watson, Stacey D

    2007-04-01

    To propose a standard definition of "out of specification" for cochlear implants and a paradigm for inclusion of category C of the ISO standard 5841-2:2000 for reporting in cumulative survival statistics. A standard definition of "out of specification" and consistent reporting by manufacturers of cochlear implants will create a fair and consistent representation of cumulative survival. This will allow discernment of differences between manufacturers for reliability and for detection of trends in reliability between model types from the same manufacturer. Three separate meetings with representatives of the three manufacturers of cochlear implants marketed in the United States were staged over a 13-mo period. Standard questions, created by the authors, were addressed by each representative to determine the current state of device reliability reporting. Results were presented to clinicians at the William House Cochlear Implant study Group and the Implantable devices sub-committee of the American Academy of Otolaryngology (2004, 2005) and at the 8th International Cochlear Implant Conference (2004) for feedback. After assimilation of feedback by all parties, the standard was written and reviewed by representatives from each manufacturer for accuracy of data. A complaint-driven standard was developed. A "cochlear implant" as an internal device placed and skin closed in surgery. An internal device is "out of specification" when one or more technical characteristics is outside the limits of normal function and results in explantation or non-use by the patient." Children will be reported separately from adults, each model of device will be reported on annually, a minimum of 200 devices must be in each model group for Cumulative Survival Reporting (CSR). Confidence limits are set at 95%. Explants will be determined to be "biological" or "technical." Technical explants are included in CSR reports. Devices failing to meet specifications set by the manufacturer, not in use but

  10. Wired to freedom: Life science, public politics, and the case of Cochlear Implantation.

    Science.gov (United States)

    Jepsen, Kim Sune; Bertilsson, T Margareta

    2017-02-01

    Cochlear Implantation is now regarded as the most successful medical technology. It carries promises to provide deaf/hearing impaired individuals with a technological sense of hearing and an access to participate on a more equal level in social life. In this article, we explore the adoption of cochlear implantations among Danish users in order to shed more light on their social and political implications. We situate cochlear implantation in a framework of new life science advances, politics, and user experiences. Analytically, we draw upon the notion of social imaginary and explore the social dimension of life science through a notion of public politics adopted from the political theory of John Dewey. We show how cochlear implantation engages different social imaginaries on the collective and individual levels and we suggest that users share an imaginary of being "wired to freedom" that involves new access to social life, continuous communicative challenges, common practices, and experiences. In looking at their lives as "wired to freedom," we hope to promote a wider spectrum of civic participation in the benefit of future life science developments within and beyond the field of Cochlear Implantation. As our empirical observations are largely based in the Scandinavian countries (notably Denmark), we also provide some reflections on the character of the technology-friendly Scandinavian welfare states and the unintended consequences that may follow in the wake of rapid technology implementation of life science in society.

  11. Speech recognition and communication outcomes with cochlear implantation in Usher syndrome type 3.

    Science.gov (United States)

    Pietola, Laura; Aarnisalo, Antti A; Abdel-Rahman, Akram; Västinsalo, Hanna; Isosomppi, Juha; Löppönen, Heikki; Kentala, Erna; Johansson, Reijo; Valtonen, Hannu; Vasama, Juha-Pekka; Sankila, Eeva-Marja; Jero, Jussi

    2012-01-01

    Usher syndrome Type 3 (USH3) is an autosomal recessive disorder characterized by variable type and degree of progressive sensorineural hearing loss and retinitis pigmentosa. Cochlear implants are widely used among these patients. To evaluate the results and benefits of cochlear implantation in patients with USH3. A nationwide multicenter retrospective review. During the years 1995-2005, in 5 Finnish university hospitals, 19 patients with USH3 received a cochlear implant. Saliva samples were collected to verify the USH3 genotype. Patients answered to 3 questionnaires: Glasgow Benefit Inventory, Glasgow Health Status Inventory, and a self-made questionnaire. Audiological data were collected from patient records. All the patients with USH3 in the study were homozygous for the Finnish major mutation (p.Y176X). Either they had severe sensorineural hearing loss or they were profoundly deaf. The mean preoperative hearing level (pure-tone average, 0.5-4 kHz) was 110 ± 8 dB hearing loss (HL) and the mean aided hearing level was 58 ± 11 dB HL. The postoperative hearing level (34 ± 9 dB HL) and word recognition scores were significantly better than before surgery. According to the Glasgow Benefit Inventory scores and Glasgow Health Status Inventory data related to hearing, the cochlear implantation was beneficial to patients with USH3. Cochlear implantation is beneficial to patients with USH3, and patients learn to use the implant without assistance.

  12. Modifying cochlear implant design: advantages of placing a return electrode in the modiolus.

    Science.gov (United States)

    Ho, Steven Y; Wiet, Richard J; Richter, Claus-Peter

    2004-07-01

    A modiolar return electrode significantly increases the current flow across spiral ganglion cells into the modiolus, and may decrease the cochlear implant's power requirements. Ideal cochlear implants should maximize current flow into the modiolus to stimulate auditory neurons. Previous efforts to facilitate current flow through the modiolus included the fabrication and use of precurved electrodes designed to "hug" the modiolus and silastic positioners designed to place the electrodes closer to the modiolus. In contrast to earlier efforts, this study explores the effects of return electrode placement on current distributions in the modiolus. The effects of return electrode positioning on current flow in the modiolus were studied in a Plexiglas model of the cochlea. Results of model measurements were confirmed by measurements in the modiolus of human temporal bones. The return electrode was placed either within the modiolus, or remotely, outside the temporal bone, simulating contemporary cochlear implant configurations using monopolar stimulation. Cochlear model results clearly show that modiolar current amplitudes can be influenced significantly by the location of the return electrode, being larger when placed into the modiolus. Temporal bone data show similar findings. Voltages recorded in the modiolus are, on average, 2.8 times higher with the return electrode in the modiolus compared with return electrode locations outside the temporal bone. Placing a cochlear implant's return electrode in the modiolus should significantly reduce its power consumption. Reducing power requirements should lead to improved efficiency, safer long-term use, and longer device life.

  13. Sirt3 confers protection against acrolein-induced oxidative stress in cochlear nucleus neurons.

    Science.gov (United States)

    Qu, Juan; Wu, Yong-Xiang; Zhang, Ting; Qiu, Yang; Ding, Zhong-Jia; Zha, Ding-Jun

    2018-03-01

    Acrolein is a ubiquitous dietary and environmental pollutant, which can also be generated endogenously during cellular stress. However, the molecular mechanisms underlying acrolein-induced neurotoxicity, especially in ototoxicity conditions, have not been fully determined. In this study, we investigated the mechanisms on acrolein-induced toxicity in primary cultured cochlear nucleus neurons with focus on Sirt3, a mitochondrial deacetylase. We found that acrolein treatment induced neuronal injury and programmed cell death (PCD) in a dose dependent manner in cochlear nucleus neurons, which was accompanied by increased intracellular reactive oxygen species (ROS) generation and lipid peroxidation. Acrolein exposure also significantly reduced the mitochondrial membrane potential (MMP) levels, promoted cytochrome c release and decreased mitochondrial ATP production. In addition, increased ER tracker fluorescence and activation of ER stress factors were observed after acrolein treatment, and the ER stress inhibitors were shown to attenuate acrolein-induced toxicity in cochlear nucleus neurons. The results of western blot and RT-PCR showed that acrolein markedly decreased the expression of Sirt3 at both mRNA and protein levels, and reduced the activity of downstream mitochondrial enzymes. Furthermore, overexpression of Sirt3 by lentivirus transfection partially prevented acrolein-induced neuronal injury in cochlear nucleus neurons. These results demonstrated that acrolein induces mitochondrial dysfunction and ER stress in cochlear nucleus neurons, and Sirt3 acts as an endogenous protective factor in acrolein-induced ototoxicity. Copyright © 2017. Published by Elsevier Ltd.

  14. One-stage human acellular nerve allograft reconstruction for digital nerve defects

    Directory of Open Access Journals (Sweden)

    Xue-yuan Li

    2015-01-01

    Full Text Available Human acellular nerve allografts have a wide range of donor origin and can effectively avoid nerve injury in the donor area. Very little is known about one-stage reconstruction of digital nerve defects. The present study observed the feasibility and effectiveness of human acellular nerve allograft in the reconstruction of < 5-cm digital nerve defects within 6 hours after injury. A total of 15 cases of nerve injury, combined with nerve defects in 18 digits from the Department of Emergency were enrolled in this study. After debridement, digital nerves were reconstructed using human acellular nerve allografts. The patients were followed up for 6-24 months after reconstruction. Mackinnon-Dellon static two-point discrimination results showed excellent and good rates of 89%. Semmes-Weinstein monofilament test demonstrated that light touch was normal, with an obvious improvement rate of 78%. These findings confirmed that human acellular nerve allograft for one-stage reconstruction of digital nerve defect after hand injury is feasible, which provides a novel trend for peripheral nerve reconstruction.

  15. Nerves and nerve endings in the skin of tropical cattle.

    Science.gov (United States)

    Amakiri, S F; Ozoya, S E; Ogunnaike, P O

    1978-01-01

    The nerves and nerve endings in the skin of tropical cattle were studied using histological and histochemical techniques. Many nerve trunks and fibres were present in the reticular and papillary dermis in both hairy and non-hairy skin sites. In non-hairy skin locations such as the muzzle and lower lip, encapsulated endings akin to Krause and Ruffini end bulbs, which arise from myelinated nerve trunks situated lower down the dermis were observed at the upper papillary layer level. Some fibre trunks seen at this level extended upwards to terminate within dermal papillae as bulb-shaped longitudinally lamellated Pacinian-type endings, while other onion-shaped lamellated nerve structures were located either within dermal papillae or near the dermo-epidermal area. Intraepidermal free-ending nerve fibres, appearing non-myelinated were observed in areas with thick epidermis. Intraepidermal free-ending nerve fibres, appearing non-myelinated were observed in areas with thick epidermis. On hairy skin sites, however, organized nerve endings or intraepidermal nerve endings were not readily identifiable.

  16. Diagnostic nerve ultrasonography

    International Nuclear Information System (INIS)

    Baeumer, T.; Grimm, A.; Schelle, T.

    2017-01-01

    For the diagnostics of nerve lesions an imaging method is necessary to visualize peripheral nerves and their surrounding structures for an etiological classification. Clinical neurological and electrophysiological investigations provide functional information about nerve lesions. The information provided by a standard magnetic resonance imaging (MRI) examination is inadequate for peripheral nerve diagnostics; however, MRI neurography is suitable but on the other hand a resource and time-consuming method. Using ultrasonography for peripheral nerve diagnostics. With ultrasonography reliable diagnostics of entrapment neuropathies and traumatic nerve lesions are possible. The use of ultrasonography for neuropathies shows that a differentiation between different forms is possible. Nerve ultrasonography is an established diagnostic tool. In addition to the clinical examination and clinical electrophysiology, structural information can be obtained, which results in a clear improvement in the diagnostics. Ultrasonography has become an integral part of the diagnostic work-up of peripheral nerve lesions in neurophysiological departments. Nerve ultrasonography is recommended for the diagnostic work-up of peripheral nerve lesions in addition to clinical and electrophysiological investigations. It should be used in the clinical work-up of entrapment neuropathies, traumatic nerve lesions and spacy-occupying lesions of nerves. (orig.) [de

  17. Nerve ultrasound shows subclinical peripheral nerve involvement in neurofibromatosis type 2.

    Science.gov (United States)

    Telleman, Johan A; Stellingwerff, Menno D; Brekelmans, Geert J; Visser, Leo H

    2018-02-01

    Neurofibromatosis type 2 (NF2) is mainly associated with central nervous system (CNS) tumors. Peripheral nerve involvement is described in symptomatic patients, but evidence of subclinical peripheral nerve involvement is scarce. We conducted a cross-sectional pilot study in 2 asymptomatic and 3 minimally symptomatic patients with NF2 to detect subclinical peripheral nerve involvement. Patients underwent clinical examination, nerve conduction studies (NCS), and high-resolution ultrasonography (HRUS). A total of 30 schwannomas were found, divided over 20 nerve segments (33.9% of all investigated nerve segments). All patients had at least 1 schwannoma. Schwannomas were identified with HRUS in 37% of clinically unaffected nerve segments and 50% of nerve segments with normal NCS findings. HRUS shows frequent subclinical peripheral nerve involvement in NF2. Clinicians should consider peripheral nerve involvement as a cause of weakness and sensory loss in the extremities in patients with this disease. Muscle Nerve 57: 312-316, 2018. © 2017 Wiley Periodicals, Inc.

  18. Gender Categorization in Cochlear Implant Users

    Science.gov (United States)

    Massida, Zoe; Marx, Mathieu; Belin, Pascal; James, Christopher; Fraysse, Bernard; Barone, Pascal; Deguine, Olivier

    2013-01-01

    Purpose: In this study, the authors examined the ability of subjects with cochlear implants (CIs) to discriminate voice gender and how this ability evolved as a function of CI experience. Method: The authors presented a continuum of voice samples created by voice morphing, with 9 intermediate acoustic parameter steps between a typical male and a…

  19. Fibro-vascular coupling in the control of cochlear blood flow.

    Directory of Open Access Journals (Sweden)

    Min Dai

    Full Text Available Transduction of sound in the cochlea is metabolically demanding. The lateral wall and hair cells are critically vulnerable to hypoxia, especially at high sound levels, and tight control over cochlear blood flow (CBF is a physiological necessity. Yet despite the importance of CBF for hearing, consensus on what mechanisms are involved has not been obtained.We report on a local control mechanism for regulating inner ear blood flow involving fibrocyte signaling. Fibrocytes in the super-strial region are spatially distributed near pre-capillaries of the spiral ligament of the albino guinea pig cochlear lateral wall, as demonstrably shown in transmission electron microscope and confocal images. Immunohistochemical techniques reveal the inter-connected fibrocytes to be positive for Na+/K+ ATPase β1 and S100. The connected fibrocytes display more Ca(2+ signaling than other cells in the cochlear lateral wall as indicated by fluorescence of a Ca(2+ sensor, fluo-4. Elevation of Ca(2+ in fibrocytes, induced by photolytic uncaging of the divalent ion chelator o-nitrophenyl EGTA, results in propagation of a Ca(2+ signal to neighboring vascular cells and vasodilation in capillaries. Of more physiological significance, fibrocyte to vascular cell coupled signaling was found to mediate the sound stimulated increase in cochlear blood flow (CBF. Cyclooxygenase-1 (COX-1 was required for capillary dilation.The findings provide the first evidence that signaling between fibrocytes and vascular cells modulates CBF and is a key mechanism for meeting the cellular metabolic demand of increased sound activity.

  20. Anatomical variations of the facial nerve in first branchial cleft anomalies.

    Science.gov (United States)

    Solares, C Arturo; Chan, James; Koltai, Peter J

    2003-03-01

    To review our experience with branchial cleft anomalies, with special attention to their subtypes and anatomical relationship to the facial nerve. Case series. Tertiary care center. Ten patients who underwent resection for anomalies of the first branchial cleft, with at least 1 year of follow-up, were included in the study. The data from all cases were collected in a prospective fashion, including immediate postoperative diagrams. Complete resection of the branchial cleft anomaly was performed in all cases. Wide exposure of the facial nerve was achieved using a modified Blair incision and superficial parotidectomy. Facial nerve monitoring was used in every case. The primary outcome measurements were facial nerve function and incidence of recurrence after resection of the branchial cleft anomaly. Ten patients, 6 females and 4 males,with a mean age of 9 years at presentation, were treated by the senior author (P.J.K.) between 1989 and 2001. The lesions were characterized as sinus tracts (n = 5), fistulous tracts (n = 3), and cysts (n = 2). Seven lesions were medial to the facial nerve, 2 were lateral to the facial nerve, and 1 was between branches of the facial nerve. There were no complications related to facial nerve paresis or paralysis, and none of the patients has had a recurrence. The successful treatment of branchial cleft anomalies requires a complete resection. A safe complete resection requires a full exposure of the facial nerve, as the lesions can be variably associated with the nerve.

  1. Communication, Psychosocial, and Educational Outcomes of Children with Cochlear Implants and Challenges Remaining for Professionals and Parents

    Directory of Open Access Journals (Sweden)

    Renée Punch

    2011-01-01

    Full Text Available This paper provides an overview and a synthesis of the findings of a large, multifaceted study investigating outcomes from paediatric cochlear implantation. The study included children implanted at several Australian implant clinics and attending a variety of early intervention and educational settings across a range of locations in eastern Australia. It investigated three major aspects of childhood cochlear implantation: (1 parental expectations of their children's implantation, (2 families' decision-making processes, and (3 the communication, social, and educational outcomes of cochlear implantation for deaf children. It employed a mixed-methods approach in which quantitative survey data were gathered from 247 parents and 151 teachers, and qualitative data from semistructured interviews with 27 parents, 15 teachers, and 11 children and adolescents with cochlear implants. The summarised findings highlight several areas where challenges remain for implant clinics, parents, and educators if children with cochlear implants are to reach their full potential personally, educationally, and socially.

  2. Cochlear Implants Keep Twin Sisters Learning, Discovering Together

    Science.gov (United States)

    ... Current Issue Past Issues Special Section: Focus on Communication Cochlear Implants Past Issues / Fall 2008 Table of ... in noisy environments—a critical ability in a classroom. Before the second implant, Mia was pulling back ...

  3. Pharmacokinetic Properties of Adenosine Amine Congener in Cochlear Perilymph after Systemic Administration

    Directory of Open Access Journals (Sweden)

    Hao Chang

    2017-01-01

    Full Text Available Noise-induced hearing loss (NIHL is a global health problem affecting over 5% of the population worldwide. We have shown previously that acute noise-induced cochlear injury can be ameliorated by administration of drugs acting on adenosine receptors in the inner ear, and a selective A1 adenosine receptor agonist adenosine amine congener (ADAC has emerged as a potentially effective treatment for cochlear injury and resulting hearing loss. This study investigated pharmacokinetic properties of ADAC in rat perilymph after systemic (intravenous administration using a newly developed liquid chromatography-tandem mass spectrometry detection method. The method was developed and validated in accordance with the USA FDA guidelines including accuracy, precision, specificity, and linearity. Perilymph was sampled from the apical turn of the cochlea to prevent contamination with the cerebrospinal fluid. ADAC was detected in cochlear perilymph within two minutes following intravenous administration and remained in perilymph above its minimal effective concentration for at least two hours. The pharmacokinetic pattern of ADAC was significantly altered by exposure to noise, suggesting transient changes in permeability of the blood-labyrinth barrier and/or cochlear blood flow. This study supports ADAC development as a potential clinical otological treatment for acute sensorineural hearing loss caused by exposure to traumatic noise.

  4. Auditory Neural Prostheses – A Window to the Future

    Directory of Open Access Journals (Sweden)

    Mohan Kameshwaran

    2015-06-01

    Full Text Available Hearing loss is one of the commonest congenital anomalies to affect children world-over. The incidence of congenital hearing loss is more pronounced in developing countries like the Indian sub-continent, especially with the problems of consanguinity. Hearing loss is a double tragedy, as it leads to not only deafness but also language deprivation. However, hearing loss is the only truly remediable handicap, due to remarkable advances in biomedical engineering and surgical techniques. Auditory neural prostheses help to augment or restore hearing by integration of an external circuitry with the peripheral hearing apparatus and the central circuitry of the brain. A cochlear implant (CI is a surgically implantable device that helps restore hearing in patients with severe-profound hearing loss, unresponsive to amplification by conventional hearing aids. CIs are electronic devices designed to detect mechanical sound energy and convert it into electrical signals that can be delivered to the coch­lear nerve, bypassing the damaged hair cells of the coch­lea. The only true prerequisite is an intact auditory nerve. The emphasis is on implantation as early as possible to maximize speech understanding and perception. Bilateral CI has significant benefits which include improved speech perception in noisy environments and improved sound localization. Presently, the indications for CI have widened and these expanded indications for implantation are related to age, additional handicaps, residual hearing, and special etiologies of deafness. Combined electric and acoustic stimulation (EAS / hybrid device is designed for individuals with binaural low-frequency hearing and severe-to-profound high-frequency hearing loss. Auditory brainstem implantation (ABI is a safe and effective means of hearing rehabilitation in patients with retrocochlear disorders, such as neurofibromatosis type 2 (NF2 or congenital cochlear nerve aplasia, wherein the cochlear nerve is damaged

  5. Polymeric Nerve Conduits with Contact Guidance Cues Used in Nerve Repair

    Institute of Scientific and Technical Information of China (English)

    G DAI; X NIU; J YIN

    2016-01-01

    In the modern life, the nerve injury frequently happens due to mechanical, chemical or thermal accidents. In the trivial injuries, the peripheral nerves can regenerate on their own; however, in most of the cases the clinical treatments are required, where relatively large nerve injury gaps are formed. Currently, the nerve repair can be accomplished by direct suture when the injury gap is not too large;while the autologous nerve graft working as the gold standard of peripheral nerve injury treatment for nerve injuries with larger gaps. However, the direct suture is limited by heavy tension at the suture sites, and the autologous nerve graft also has the drawbacks of donor site morbidity and insufifcient donor tissue. Recently, artiifcial nerve conduits have been developed as an alternative for clinical nerve repair to overcome the limitations associated with the above treatments. In order to further improve the efifciency of nerve conduits, various guidance cues are incorporated, including physical cues, biochemical signals, as well as support cells. First, this paper reviewed the contact guidance cues applied in nerve conduits, such as lumen ifllers, multi-channels and micro-patterns on the inner surface. Then, the paper focused on the polymeric nerve conduits with micro inner grooves. The polymeric nerve conduits were fabricated using the phase inversion-based ifber spinning techniques. The smart spinneret with grooved die was designed in the spinning platform, while different spinning conditions, including flow rates, air-gap distances, and polymer concentrations, were adjusted to investigate the inlfuence of fabrication conditions on the geometry of nerve conduits. The inner groove size in the nerve conduits can be precisely controlled in our hollow ifber spinning process, which can work as the efifcient contact guidance cue for nerve regeneration.

  6. Temporal and spectral contributions to musical instrument identification and discrimination among cochlear implant users.

    Science.gov (United States)

    Prentiss, Sandra M; Friedland, David R; Fullmer, Tanner; Crane, Alison; Stoddard, Timothy; Runge, Christina L

    2016-09-01

    To investigate the contributions of envelope and fine-structure to the perception of timbre by cochlear implant (CI) users as compared to normal hearing (NH) listeners. This was a prospective cohort comparison study. Normal hearing and cochlear implant patients were tested. Three experiments were performed in sound field using musical notes altered to affect the characteristic pitch of an instrument and the acoustic envelope. Experiment 1 assessed the ability to identify the instrument playing each note, while experiments 2 and 3 assessed the ability to discriminate the different stimuli. Normal hearing subjects performed better than CI subjects in all instrument identification tasks, reaching statistical significance for 4 of 5 stimulus conditions. Within the CI population, acoustic envelope modifications did not significantly affect instrument identification or discrimination. With envelope and pitch cues removed, fine structure discrimination performance was similar between normal hearing and CI users for the majority of conditions, but some specific instrument comparisons were significantly more challenging for CI users. Cochlear implant users perform significantly worse than normal hearing listeners on tasks of instrument identification. However, cochlear implant listeners can discriminate differences in envelope and some fine structure components of musical instrument sounds as well as normal hearing listeners. The results indicated that certain fine structure cues are important for cochlear implant users to make discrimination judgments, and therefore may affect interpretation toward associating with a specific instrument for identification.

  7. Tissue-engineered spiral nerve guidance conduit for peripheral nerve regeneration.

    Science.gov (United States)

    Chang, Wei; Shah, Munish B; Lee, Paul; Yu, Xiaojun

    2018-06-01

    Recently in peripheral nerve regeneration, preclinical studies have shown that the use of nerve guidance conduits (NGCs) with multiple longitudinally channels and intra-luminal topography enhance the functional outcomes when bridging a nerve gap caused by traumatic injury. These features not only provide guidance cues for regenerating nerve, but also become the essential approaches for developing a novel NGC. In this study, a novel spiral NGC with aligned nanofibers and wrapped with an outer nanofibrous tube was first developed and investigated. Using the common rat sciatic 10-mm nerve defect model, the in vivo study showed that a novel spiral NGC (with and without inner nanofibers) increased the successful rate of nerve regeneration after 6 weeks recovery. Substantial improvements in nerve regeneration were achieved by combining the spiral NGC with inner nanofibers and outer nanofibrous tube, based on the results of walking track analysis, electrophysiology, nerve histological assessment, and gastrocnemius muscle measurement. This demonstrated that the novel spiral NGC with inner aligned nanofibers and wrapped with an outer nanofibrous tube provided a better environment for peripheral nerve regeneration than standard tubular NGCs. Results from this study will benefit for future NGC design to optimize tissue-engineering strategies for peripheral nerve regeneration. We developed a novel spiral nerve guidance conduit (NGC) with coated aligned nanofibers. The spiral structure increases surface area by 4.5 fold relative to a tubular NGC. Furthermore, the aligned nanofibers was coated on the spiral walls, providing cues for guiding neurite extension. Finally, the outside of spiral NGC was wrapped with randomly nanofibers to enhance mechanical strength that can stabilize the spiral NGC. Our nerve histological data have shown that the spiral NGC had 50% more myelinated axons than a tubular structure for nerve regeneration across a 10 mm gap in a rat sciatic nerve

  8. The Construct Validity and Reliability of an Assessment Tool for Competency in Cochlear Implant Surgery

    Directory of Open Access Journals (Sweden)

    Patorn Piromchai

    2014-01-01

    Full Text Available Introduction. We introduce a rating tool that objectively evaluates the skills of surgical trainees performing cochlear implant surgery. Methods. Seven residents and seven experts performed cochlear implant surgery sessions from mastoidectomy to cochleostomy on a standardized virtual reality temporal bone. A total of twenty-eight assessment videos were recorded and two consultant otolaryngologists evaluated the performance of each participant using these videos. Results. Interrater reliability was calculated using the intraclass correlation coefficient for both the global and checklist components of the assessment instrument. The overall agreement was high. The construct validity of this instrument was strongly supported by the significantly higher scores in the expert group for both components. Conclusion. Our results indicate that the proposed assessment tool for cochlear implant surgery is reliable, accurate, and easy to use. This instrument can thus be used to provide objective feedback on overall and task-specific competency in cochlear implantation.

  9. Parametric model of the scala tympani for haptic-rendered cochlear implantation.

    Science.gov (United States)

    Todd, Catherine; Naghdy, Fazel

    2005-01-01

    A parametric model of the human scala tympani has been designed for use in a haptic-rendered computer simulation of cochlear implant surgery. It will be the first surgical simulator of this kind. A geometric model of the Scala Tympani has been derived from measured data for this purpose. The model is compared with two existing descriptions of the cochlear spiral. A first approximation of the basilar membrane is also produced. The structures are imported into a force-rendering software application for system development.

  10. Neural tissue engineering options for peripheral nerve regeneration.

    Science.gov (United States)

    Gu, Xiaosong; Ding, Fei; Williams, David F

    2014-08-01

    Tissue engineered nerve grafts (TENGs) have emerged as a potential alternative to autologous nerve grafts, the gold standard for peripheral nerve repair. Typically, TENGs are composed of a biomaterial-based template that incorporates biochemical cues. A number of TENGs have been used experimentally to bridge long peripheral nerve gaps in various animal models, where the desired outcome is nerve tissue regeneration and functional recovery. So far, the translation of TENGs to the clinic for use in humans has met with a certain degree of success. In order to optimize the TENG design and further approach the matching of TENGs with autologous nerve grafts, many new cues, beyond the traditional ones, will have to be integrated into TENGs. Furthermore, there is a strong requirement for monitoring the real-time dynamic information related to the construction of TENGs. The aim of this opinion paper is to specifically and critically describe the latest advances in the field of neural tissue engineering for peripheral nerve regeneration. Here we delineate new attempts in the design of template (or scaffold) materials, especially in the context of biocompatibility, the choice and handling of support cells, and growth factor release systems. We further discuss the significance of RNAi for peripheral nerve regeneration, anticipate the potential application of RNAi reagents for TENGs, and speculate on the possible contributions of additional elements, including angiogenesis, electrical stimulation, molecular inflammatory mediators, bioactive peptides, antioxidant reagents, and cultured biological constructs, to TENGs. Finally, we consider that a diverse array of physicochemical and biological cues must be orchestrated within a TENG to create a self-consistent coordinated system with a close proximity to the regenerative microenvironment of the peripheral nervous system. Copyright © 2014 Elsevier Ltd. All rights reserved.

  11. Sensation, mechanoreceptor, and nerve fiber function after nerve regeneration

    DEFF Research Database (Denmark)

    Krarup, Christian; Rosén, Birgitta; Boeckstyns, Michel

    2017-01-01

    Objective: Sensation is essential for recovery after peripheral nerve injury. However, the relationship between sensory modalities and function of regenerated fibers is uncertain. We have investigated the relationships between touch threshold, tactile gnosis, and mechanoreceptor and sensory fiber...... function after nerve regeneration. Methods: Twenty-one median or ulnar nerve lesions were repaired by a collagen nerve conduit or direct suture. Quantitative sensory hand function and sensory conduction studies by near-nerve technique, including tactile stimulation of mechanoreceptors, were followed for 2...... years, and results were compared to noninjured hands. Results: At both repair methods, touch thresholds at the finger tips recovered to 81 ± 3% and tactile gnosis only to 20 ± 4% (p nerve action potentials (SNAPs) remained dispersed and areas recovered to 23 ± 2...

  12. The role of great auricular-facial nerve neurorrhaphy in facial nerve damage

    OpenAIRE

    Sun, Yan; Liu, Limei; Han, Yuechen; Xu, Lei; Zhang, Daogong; Wang, Haibo

    2015-01-01

    Background: Facial nerve is easy to be damaged, and there are many reconstructive methods for facial nerve reconstructive, such as facial nerve end to end anastomosis, the great auricular nerve graft, the sural nerve graft, or hypoglossal-facial nerve anastomosis. However, there is still little study about great auricular-facial nerve neurorrhaphy. The aim of the present study was to identify the role of great auricular-facial nerve neurorrhaphy and the mechanism. Methods: Rat models of facia...

  13. Modeling of Auditory Neuron Response Thresholds with Cochlear Implants

    Directory of Open Access Journals (Sweden)

    Frederic Venail

    2015-01-01

    Full Text Available The quality of the prosthetic-neural interface is a critical point for cochlear implant efficiency. It depends not only on technical and anatomical factors such as electrode position into the cochlea (depth and scalar placement, electrode impedance, and distance between the electrode and the stimulated auditory neurons, but also on the number of functional auditory neurons. The efficiency of electrical stimulation can be assessed by the measurement of e-CAP in cochlear implant users. In the present study, we modeled the activation of auditory neurons in cochlear implant recipients (nucleus device. The electrical response, measured using auto-NRT (neural responses telemetry algorithm, has been analyzed using multivariate regression with cubic splines in order to take into account the variations of insertion depth of electrodes amongst subjects as well as the other technical and anatomical factors listed above. NRT thresholds depend on the electrode squared impedance (β = −0.11 ± 0.02, P<0.01, the scalar placement of the electrodes (β = −8.50 ± 1.97, P<0.01, and the depth of insertion calculated as the characteristic frequency of auditory neurons (CNF. Distribution of NRT residues according to CNF could provide a proxy of auditory neurons functioning in implanted cochleas.

  14. Cochlear implantation in children with Jervell and Lange-Nielsen syndrome - a cautionary tale.

    Science.gov (United States)

    Broomfield, Stephen J; Bruce, Iain A; Henderson, Lise; Ramsden, Richard T; Green, Kevin M J

    2012-08-01

    Jervell and Lange-Nielsen (JLN) syndrome is a rare cause of congenital profound hearing loss associated with a prolonged QT interval on the electrocardiogram. Children presenting for cochlear implantation with this condition may be asymptomatic but are at risk of sudden death. SCREENING AND SUBSEQUENT: careful management is therefore required to ensure a successful outcome. We present our experience of cochlear implantation in children with JLN syndrome, including two who died unexpectedly, and suggest a protocol for management of such cases. Clinical presentation Four cases of cochlear implantation in JLN syndrome are described. None had any previous cardiological family history. Two were diagnosed pre-operatively but, despite appropriate management under a cardiologist, died from cardiac arrest; the first in the perioperative period following reimplantation for infection, and the second unrelated to his cochlear implant surgery. The other two patients were diagnosed only subsequent to their implantation and continue to use their implants successfully. These cases highlight the variation in presentation of JLN syndrome, and the spectrum of disease severity that exists. Our protocol stresses the importance of careful assessment and counselling of parents by an experienced implant team.

  15. Study of the Carrier-Aided Thin Film Electrode Array Design for Cochlear Insertion

    Directory of Open Access Journals (Sweden)

    Yuchen Xu

    2018-04-01

    Full Text Available The micro-fabricated thin film electrode array (TFEA has been a promising design for cochlear implants (CIs because of its cost-effectiveness and fabrication precision. The latest polymer-based cochlear TFEAs have faced difficulties for cochlear insertion due to the lack of structural stiffness. To stiffen the TFEA, dissolvable stiffening materials, TFEAs with different structures, and TFEAs with commercial CIs as carriers have been invested. In this work, the concept of enhancing a Parylene TFEA with Kapton tape as a simpler carrier for cochlear insertion has been proved to be feasible. The bending stiffness of the Kapton-aided TFEA was characterized with an analytical model, a finite element model, and a cantilever bending experiment, respectively. While the Kapton tape increased the bending stiffness of the Parylene TFEA by 103 times, the 6-μm-thick TFEA with a similar Young’s modulus, as a polyimide, in turn significantly increased the bending stiffness of the 170-μm-thick Kapton carrier by 60%. This result indicated that even the TFEA is ultra-flexible and that its bending stiffness should not be neglected in the design or selection of its carrier.

  16. Speech and language development in cognitively delayed children with cochlear implants.

    Science.gov (United States)

    Holt, Rachael Frush; Kirk, Karen Iler

    2005-04-01

    The primary goals of this investigation were to examine the speech and language development of deaf children with cochlear implants and mild cognitive delay and to compare their gains with those of children with cochlear implants who do not have this additional impairment. We retrospectively examined the speech and language development of 69 children with pre-lingual deafness. The experimental group consisted of 19 children with cognitive delays and no other disabilities (mean age at implantation = 38 months). The control group consisted of 50 children who did not have cognitive delays or any other identified disability. The control group was stratified by primary communication mode: half used total communication (mean age at implantation = 32 months) and the other half used oral communication (mean age at implantation = 26 months). Children were tested on a variety of standard speech and language measures and one test of auditory skill development at 6-month intervals. The results from each test were collapsed from blocks of two consecutive 6-month intervals to calculate group mean scores before implantation and at 1-year intervals after implantation. The children with cognitive delays and those without such delays demonstrated significant improvement in their speech and language skills over time on every test administered. Children with cognitive delays had significantly lower scores than typically developing children on two of the three measures of receptive and expressive language and had significantly slower rates of auditory-only sentence recognition development. Finally, there were no significant group differences in auditory skill development based on parental reports or in auditory-only or multimodal word recognition. The results suggest that deaf children with mild cognitive impairments benefit from cochlear implantation. Specifically, improvements are evident in their ability to perceive speech and in their reception and use of language. However, it may

  17. The role of great auricular-facial nerve neurorrhaphy in facial nerve damage.

    Science.gov (United States)

    Sun, Yan; Liu, Limei; Han, Yuechen; Xu, Lei; Zhang, Daogong; Wang, Haibo

    2015-01-01

    Facial nerve is easy to be damaged, and there are many reconstructive methods for facial nerve reconstructive, such as facial nerve end to end anastomosis, the great auricular nerve graft, the sural nerve graft, or hypoglossal-facial nerve anastomosis. However, there is still little study about great auricular-facial nerve neurorrhaphy. The aim of the present study was to identify the role of great auricular-facial nerve neurorrhaphy and the mechanism. Rat models of facial nerve cut (FC), facial nerve end to end anastomosis (FF), facial-great auricular neurorrhaphy (FG), and control (Ctrl) were established. Apex nasi amesiality observation, electrophysiology and immunofluorescence assays were employed to investigate the function and mechanism. In apex nasi amesiality observation, it was found apex nasi amesiality of FG group was partly recovered. Additionally, electrophysiology and immunofluorescence assays revealed that facial-great auricular neurorrhaphy could transfer nerve impulse and express AChR which was better than facial nerve cut and worse than facial nerve end to end anastomosis. The present study indicated that great auricular-facial nerve neurorrhaphy is a substantial solution for facial lesion repair, as it is efficiently preventing facial muscles atrophy by generating neurotransmitter like ACh.

  18. Pinched Nerve

    Science.gov (United States)

    ... You are here Home » Disorders » All Disorders Pinched Nerve Information Page Pinched Nerve Information Page What research is being done? Within the NINDS research programs, pinched nerves are addressed primarily through studies associated with pain ...

  19. Can cochlear implantation improve neurocognition in the aging population?

    Directory of Open Access Journals (Sweden)

    Völter C

    2018-04-01

    Full Text Available Christiane Völter,1 Lisa Götze,1 Stefan Dazert,1 Michael Falkenstein,2,3 Jan Peter Thomas1 1Department of Otorhinolaryngology, Head and Neck Surgery, Ruhr University Bochum, St. Elisabeth-Hospital, Bochum, Germany; 2Institute for Work, Learning and Ageing (ALA, Bochum, Germany; 3Leibniz Research Centre for Working Environment and Human Factors, Dortmund, Germany Introduction: The relationship between cognition and the ability to hear is well known. Due to changes in demographics, the number of people with sensorineural hearing loss and cognitive impairment is increasing. The aim of this study was to identify the impact of hearing rehabilitation via cochlear implantation on cognitive decline among the aging population. Patients and methods: This prospective study included 60 subjects aged between 50 and 84 years (mean 65.8 years, SD=8.9 with a severe to profound bilateral hearing impairment. A computer-based evaluation of short- and long-term memory, processing speed, attention, working memory and inhibition was performed prior to surgery as well as 6 and 12 months after cochlear implantation. Additionally, speech perception at 65 and 80 dB (Freiburger monosyllabic speech test as well as disease-related (Nijmegen Cochlear Implant Questionnaire and general (WHOQOL-OLD quality of life were assessed. Results: Six months postimplantation, speech perception, quality of life and also neurocognitive abilities significantly increased. The most remarkable improvement after 6 months was detected in executive functions such as attention (p<0.001, inhibition (p=0.025 and working memory (n-back: p=0.002; operation span task: p=0.008, followed by delayed recall (p=0.03. In contrast, long-term memory showed a significant change of performance only after 12 months (p=0.021. After 6 months, most cognitive domains remained stable, except working memory assessed by the operation span task, which significantly improved between 6 and 12 months (p<0.001. No

  20. Recognition of "real-world" musical excerpts by cochlear implant recipients and normal-hearing adults.

    Science.gov (United States)

    Gfeller, Kate; Olszewski, Carol; Rychener, Marly; Sena, Kimberly; Knutson, John F; Witt, Shelley; Macpherson, Beth

    2005-06-01

    The purposes of this study were (a) to compare recognition of "real-world" music excerpts by postlingually deafened adults using cochlear implants and normal-hearing adults; (b) to compare the performance of cochlear implant recipients using different devices and processing strategies; and (c) to examine the variability among implant recipients in recognition of musical selections in relation to performance on speech perception tests, performance on cognitive tests, and demographic variables. Seventy-nine cochlear implant users and 30 normal-hearing adults were tested on open-set recognition of systematically selected excerpts from musical recordings heard in real life. The recognition accuracy of the two groups was compared for three musical genre: classical, country, and pop. Recognition accuracy was correlated with speech recognition scores, cognitive measures, and demographic measures, including musical background. Cochlear implant recipients were significantly less accurate in recognition of previously familiar (known before hearing loss) musical excerpts than normal-hearing adults (p genre. Implant recipients were most accurate in the recognition of country items and least accurate in the recognition of classical items. There were no significant differences among implant recipients due to implant type (Nucleus, Clarion, or Ineraid), or programming strategy (SPEAK, CIS, or ACE). For cochlear implant recipients, correlations between melody recognition and other measures were moderate to weak in strength; those with statistically significant correlations included age at time of testing (negatively correlated), performance on selected speech perception tests, and the amount of focused music listening following implantation. Current-day cochlear implants are not effective in transmitting several key structural features (i.e., pitch, harmony, timbral blends) of music essential to open-set recognition of well-known musical selections. Consequently, implant

  1. Surgical complications following cochlear implantation in adults based on a proposed reporting consensus

    DEFF Research Database (Denmark)

    Jeppesen, Jonas; Faber, Christian Emil

    2013-01-01

    Abstract Conclusion: The rate of severe complications was low and cochlear implantation is a relatively safe procedure. Standardization is crucial when reporting on cochlear implant complications to ensure comparability between studies. A consensus on the reporting of complications proposed by a ...... occurred following one implantation (0.3%). Transient chorda tympani syndrome (30.8%), vertigo/dizziness (29.5%) and tinnitus (4.9%) were the most frequent minor complications....

  2. Assessment of nerve regeneration across nerve allografts treated with tacrolimus.

    Science.gov (United States)

    Haisheng, Han; Songjie, Zuo; Xin, Li

    2008-01-01

    Although regeneration of nerve allotransplant is a major concern in the clinic, there have been few papers quantitatively assessing functional recovery of animals' nerve allografts in the long term. In this study, functional recovery, histopathological study, and immunohistochemistry changes of rat nerve allograft with FK506 were investigated up to 12 weeks without slaughtering. C57 and SD rats were used for transplantation. The donor's nerve was sliced and transplanted into the recipient. The sciatic nerve was epineurally sutured with 10-0 nylon. In total, 30 models of transplantation were performed and divided into 3 groups that were either treated with FK506 or not. Functional recovery of the grafted nerve was serially assessed by the pin click test, walking track analysis and electrophysiological evaluations. A histopathological study and immunohistochemistry study were done in the all of the models. Nerve allografts treated with FK506 have no immune rejection through 12 weeks. Sensibility had similarly improved in both isografts and allografts. There has been no difference in each graft. Walk track analysis demonstrates significant recovery of motor function of the nerve graft. No histological results of difference were found up to 12 weeks in each graft. In the rodent nerve graft model, FK506 prevented nerve allograft rejection across a major histocompatibility barrier. Sensory recovery seems to be superior to motor function. Nerve isograft and allograft treated with FK506 have no significant difference in function recovery, histopathological result, and immunohistochemistry changes.

  3. Functional Nerve Preservation in Extracranial Head and Neck Schwannoma Surgery.

    Science.gov (United States)

    Ijichi, Kei; Kawakita, Daisuke; Maseki, Shinichiro; Beppu, Shintaro; Takano, Gaku; Murakami, Shingo

    2016-05-01

    A schwannoma is an uncommon, benign neurogenic tumor of Schwann cells. Tumor enucleation is the recommended surgical method to preserve function of the original nerve, although enucleation does not guarantee completely intact nerve function after the operation. To establish a strategy for functional preservation in extracranial head and neck schwannoma treatment by using an electromyographic (EMG) system during tumor resection. A retrospective cohort study was conducted of 15 patients who underwent surgery for removal of schwannoma tumors between April 1, 2006, and March 31, 2015, at an academic tertiary referral center. Data analysis was conducted from April 3, 2006, to September 15, 2015. Neurogenic tumors were diagnosed according to preoperative findings, and during surgery tumors were exposed and given EMG-controlled electrical stimulation to analyze their origins. In motor nerve cases, the electrical activity of the muscle was measured and recorded by EMG. The tumor was then enucleated by incision along tumor fibers mapped using EMG stimulation. If a nerve bundle was visible, we incised along there and enucleated the tumor. A strategy using electrical stimulation to improve preservation of nerve function in extracranial head and neck schwannoma operations. Frequency and duration of postoperative neurologic complications associated with functional preservation surgery with tumor enucleation was evaluated using EMG monitoring according to tumor origin. Of the 15 patients with extracranial schwannoma, 9 (60%) were women (mean [SD] age, 36.3 [15.3] years). All 15 patients underwent surgery using a transcervical approach. The most common nerves of origin were the vagus nerve and the sympathetic chain. In sensory or sympathetic nerve cases, the EMG response was absent. Two of 5 patients with vagus schwannoma had postoperative temporary vocal nerve palsy. These symptoms showed improvement after 1 year. There was no tumor recurrence during the follow-up period in any

  4. Cochlear implant magnet retrofit.

    Science.gov (United States)

    Cohen, N L; Breda, S D; Hoffman, R A

    1988-06-01

    An implantable magnet is now available for patients who have received the standard Nucleus 22-channel cochlear implant and who are not able to wear the headband satisfactorily. This magnet is attached in piggy-back fashion to the previously implanted receiver/stimulator by means of a brief operation under local anesthesia. Two patients have received this magnet retrofit, and are now wearing the headset with greater comfort and satisfaction. It is felt that the availability of this magnet will increase patient compliance in regard to hours of implant usage.

  5. Self-esteem and social well-being of children with cochlear implant compared to normal-hearing children

    DEFF Research Database (Denmark)

    Percy-Smith, L.; Caye-Thomasen, P.; Gudman, M.

    2008-01-01

    Objective: The purpose of this study was to make a quantitative comparison of parameters of self-esteem and social well-being between children with cochlear implants and normal-hearing children. Material and methods: Data were obtained from 164 children with cochlear implant (CI) and 2169 normal......-hearing children (NH). Parental questionnaires, used in a national survey assessing the self-esteem and well-being of normal-hearing children, were applied to the cochlear implanted group, in order to allow direct comparisons. Results: The children in the CI group rated significantly higher on questions about well...... overall self-esteem or number of friends. The two groups of children scored similarly on being confident, independent, social, not worried and happy. Conclusion: Children with cochlear implant score equal to or better than their normal-hearing peers on matters of self-esteem and social well-being. (C...

  6. Simultaneous bilateral cochlear implantation in a five-month-old child with Usher syndrome.

    Science.gov (United States)

    Alsanosi, A A

    2015-09-01

    To report a rare case of simultaneous bilateral cochlear implantation in a five-month-old child with Usher syndrome. Case report. A five-month-old boy with Usher syndrome and congenital profound bilateral deafness underwent simultaneous bilateral cochlear implantation. The decision to perform implantation in such a young child was based on his having a supportive family and the desire to foster his audiological development before his vision deteriorated. The subject experienced easily resolvable intra- and post-operative adverse events, and was first fitted with an externally worn audio processor four weeks after implantation. At 14 months of age, his audiological development was age-appropriate. Simultaneous bilateral cochlear implantation is possible, and even advisable, in children as young as five months old when performed by an experienced implantation team.

  7. Paediatric Cochlear Implantation in Patients with Waardenburg Syndrome.

    Science.gov (United States)

    van Nierop, Josephine W I; Snabel, Rebecca R; Langereis, Margreet; Pennings, Ronald J E; Admiraal, Ronald J C; Mylanus, Emmanuel A M; Kunst, Henricus P M

    2016-01-01

    To analyse the benefit of cochlear implantation in young deaf children with Waardenburg syndrome (WS) compared to a reference group of young deaf children without additional disabilities. A retrospective study was conducted on children with WS who underwent cochlear implantation at the age of 2 years or younger. The post-operative results for speech perception (phonetically balanced standard Dutch consonant-vocal-consonant word lists) and language comprehension (the Reynell Developmental Language Scales, RDLS), expressed as a language quotient (LQ), were compared between the WS group and the reference group by using multiple linear regression analysis. A total of 14 children were diagnosed with WS, and 6 of them had additional disabilities. The WS children were implanted at a mean age of 1.6 years and the 48 children of the reference group at a mean age of 1.3 years. The WS children had a mean phoneme score of 80% and a mean LQ of 0.74 at 3 years post-implantation, and these results were comparable to those of the reference group. Only the factor additional disabilities had a significant negative influence on auditory perception and language comprehension. Children with WS performed similarly to the reference group in the present study, and these outcomes are in line with the previous literature. Although good counselling about additional disabilities concomitant to the syndrome is relevant, cochlear implantation is a good rehabilitation method for children with WS. © 2016 S. Karger AG, Basel.

  8. Balance Performance of Deaf Children With and Without Cochlear Implants

    Directory of Open Access Journals (Sweden)

    Amir-Abbas Ebrahimi

    2016-12-01

    Full Text Available  The aim of this study was to compare the static and dynamic balance performance of deaf children with and without cochlear implants. This is a cross-sectional study of 145 school children, aged between 7 and 12 years comprising 85 children with congenital or early acquired bilateral profound sensorineural hearing loss (the hearing loss group and 60 normal hearing aged-matched control counterparts were assessed using the balance subtest of Bruininks-Oseretsky test of Motor Proficiency (BOTMP. The hearing loss group, 50 without cochlear implants (the non-implant group and 35 of them with unilateral cochlear implants (the implant group were recruited from schools for the deaf and normal hearing children (the control group randomly selected from two randomly selected elementary schools of Tehran city. The scores were analyzed using one-way ANOVA. The total score of deaf children especially the implant group were significantly lower than the control group P<0.001. The balance performance of the control group was better than the implant group in all of the items as well as the non-implant group except the fourth tested item (walking forward on a line (P<0.05. The balance score of the implant group was significantly lower than the non-implant group except for the third tested item (standing on the preferred leg on a balance beam with eyes closed. The findings suggested that deaf children, specifically those with cochlear implants are at risk for motor and balance deficits. Thus, vestibular and motor evaluations, as well as interventions to improve balance and motor skills, should be prioritized for this population.

  9. Intraoperative Cochlear Implant Device Testing Utilizing an Automated Remote System: A Prospective Pilot Study.

    Science.gov (United States)

    Lohmann, Amanda R; Carlson, Matthew L; Sladen, Douglas P

    2018-03-01

    Intraoperative cochlear implant device testing provides valuable information regarding device integrity, electrode position, and may assist with determining initial stimulation settings. Manual intraoperative device testing during cochlear implantation requires the time and expertise of a trained audiologist. The purpose of the current study is to investigate the feasibility of using automated remote intraoperative cochlear implant reverse telemetry testing as an alternative to standard testing. Prospective pilot study evaluating intraoperative remote automated impedance and Automatic Neural Response Telemetry (AutoNRT) testing in 34 consecutive cochlear implant surgeries using the Intraoperative Remote Assistant (Cochlear Nucleus CR120). In all cases, remote intraoperative device testing was performed by trained operating room staff. A comparison was made to the "gold standard" of manual testing by an experienced cochlear implant audiologist. Electrode position and absence of tip fold-over was confirmed using plain film x-ray. Automated remote reverse telemetry testing was successfully completed in all patients. Intraoperative x-ray demonstrated normal electrode position without tip fold-over. Average impedance values were significantly higher using standard testing versus CR120 remote testing (standard mean 10.7 kΩ, SD 1.2 vs. CR120 mean 7.5 kΩ, SD 0.7, p automated testing with regard to the presence of open or short circuits along the array. There were, however, two cases in which standard testing identified an open circuit, when CR120 testing showed the circuit to be closed. Neural responses were successfully obtained in all patients using both systems. There was no difference in basal electrode responses (standard mean 195.0 μV, SD 14.10 vs. CR120 194.5 μV, SD 14.23; p = 0.7814); however, more favorable (lower μV amplitude) results were obtained with the remote automated system in the apical 10 electrodes (standard 185.4 μV, SD 11.69 vs. CR

  10. A speech processing study using an acoustic model of a multiple-channel cochlear implant

    Science.gov (United States)

    Xu, Ying

    1998-10-01

    A cochlear implant is an electronic device designed to provide sound information for adults and children who have bilateral profound hearing loss. The task of representing speech signals as electrical stimuli is central to the design and performance of cochlear implants. Studies have shown that the current speech- processing strategies provide significant benefits to cochlear implant users. However, the evaluation and development of speech-processing strategies have been complicated by hardware limitations and large variability in user performance. To alleviate these problems, an acoustic model of a cochlear implant with the SPEAK strategy is implemented in this study, in which a set of acoustic stimuli whose psychophysical characteristics are as close as possible to those produced by a cochlear implant are presented on normal-hearing subjects. To test the effectiveness and feasibility of this acoustic model, a psychophysical experiment was conducted to match the performance of a normal-hearing listener using model- processed signals to that of a cochlear implant user. Good agreement was found between an implanted patient and an age-matched normal-hearing subject in a dynamic signal discrimination experiment, indicating that this acoustic model is a reasonably good approximation of a cochlear implant with the SPEAK strategy. The acoustic model was then used to examine the potential of the SPEAK strategy in terms of its temporal and frequency encoding of speech. It was hypothesized that better temporal and frequency encoding of speech can be accomplished by higher stimulation rates and a larger number of activated channels. Vowel and consonant recognition tests were conducted on normal-hearing subjects using speech tokens processed by the acoustic model, with different combinations of stimulation rate and number of activated channels. The results showed that vowel recognition was best at 600 pps and 8 activated channels, but further increases in stimulation rate and

  11. Peripheral nerve regeneration through P(DLLA-epsilon-CL) nerve guides

    NARCIS (Netherlands)

    Den Dunnen, WFA; Meek, MF; Robinson, PH; Schakernraad, JM

    1998-01-01

    P(DLLA-epsilon-CL) nerve guides can be used perfectly for short nerve gaps in rats, and are even better than short autologous nerve grafts. The tube dimensions, such as the internal diameter and wall thickness, are very important for the final outcome of peripheral nerve regeneration, as well as the

  12. Central transport and distribution of labelled glutamic and aspartic acids to the cochlear nucleus in cats

    International Nuclear Information System (INIS)

    Kane, E.S.

    1979-01-01

    Tritiated L-glutamic acid or L-aspartic acid was injected unilaterally into the cochleas of adult cats, and 4 h-7 days later the localization of label was studied by light-microscopic autoradiography in sections of the brain stem. Consistent differences in labelling after glutamate and after aspartate suggest differences in their uptake, metabolic conversion and/or transport to the cochlear nucleus by cochlear fibers. The morphological differences shown here agree with the distribution of those two amino acids in the cat cochlear nucleus as shown by microchemical analyses. (author)

  13. Identifying cochlear implant channels with poor electrode-neuron interface: electrically-evoked auditory brainstem responses measured with the partial tripolar configuration

    Science.gov (United States)

    Bierer, Julie Arenberg; Faulkner, Kathleen F.; Tremblay, Kelly L.

    2011-01-01

    Objectives The goal of this study was to compare cochlear implant behavioral measures and electrically-evoked auditory brainstem responses (EABRs) obtained with a spatially focused electrode configuration. It has been shown previously that channels with high thresholds, when measured with the tripolar configuration, exhibit relatively broad psychophysical tuning curves (Bierer and Faulkner, 2010). The elevated threshold and degraded spatial/spectral selectivity of such channels are consistent with a poor electrode-neuron interface, such as suboptimal electrode placement or reduced nerve survival. However, the psychophysical methods required to obtain these data are time intensive and may not be practical during a clinical mapping procedure, especially for young children. Here we have extended the previous investigation to determine if a physiological approach could provide a similar assessment of channel functionality. We hypothesized that, in accordance with the perceptual measures, higher EABR thresholds would correlate with steeper EABR amplitude growth functions, reflecting a degraded electrode-neuron interface. Design Data were collected from six cochlear implant listeners implanted with the HiRes 90k cochlear implant (Advanced Bionics). Single-channel thresholds and most comfortable listening levels were obtained for stimuli that varied in presumed electrical field size by using the partial tripolar configuration, for which a fraction of current (σ) from a center active electrode returns through two neighboring electrodes and the remainder through a distant indifferent electrode. EABRs were obtained in each subject for the two channels having the highest and lowest tripolar (σ=1 or 0.9) behavioral threshold. Evoked potentials were measured with both the monopolar (σ=0) and a more focused partial tripolar (σ ≥ 0.50) configuration. Results Consistent with previous studies, EABR thresholds were highly and positively correlated with behavioral thresholds

  14. 小儿脑神经发育监测的临床分析研究%Study of clinical analysis for the monitoring of nerve development in infants

    Institute of Scientific and Technical Information of China (English)

    吴胜兰; 韩璐; 马丙慧; 毛芳慧

    2012-01-01

    Objective: To understand the importance of early detection and intervention or rehabilitation therapy of abnormal infants , through systematic monitoring pediatric cranial nerve development, to guarantee the normal growth of pediatric cranial nerve and to protect infants from being handicapped. Methods; File cases 28 days after babies' birth and monitor the growth of cranial nerve of infants aged 0-3 with NBNA and heart scale. After monitoring, make a special management of abnormal infants' cases and record information about intervention and rehabilitation. Randomly choose files set from 2007 to 2009 as samples to make a contrast study. Consequences : Through contrasting the monitoring results, we learn that there exists a great difference between the developing level of cranial nerve of normal infants and that of the abnormal. More abnormal infants fall behind. What's more, there also exists a great difference between the intervened infants and those haven't been intervened. More of the latter lag behind in intelligence. Conclusion; The systematic monitoring of pediatric cranial nerve development, proved to be the first preventing step, is of great importance to the brain damage detection and the early diagnose intervention, and rehabilitation of unbalanced growth of abnormal infants. In addition, it is the key measure to reduce the incidence rate of handicapped children.%目的 通过对小儿脑神经发育系统监测的研究,了解早期发现高危异常儿并早期干预或康复治疗,对保障小儿脑神经生正常生长发育以及防止残障的重要作用.方法 本院出生后的婴儿从28天开始建档,采用NBNA和儿心量表进行0-3岁系统脑神经发育监测,高危儿专案管理,对干预康复治疗小儿做好记录,本研究选取2007 - 2009年监测档案随机抽样做对照研究.结果

  15. Hearing loss patterns after cochlear implantation via the round window in an animal model.

    Science.gov (United States)

    Attias, Joseph; Hod, Roy; Raveh, Eyal; Mizrachi, Aviram; Avraham, Karen B; Lenz, Danielle R; Nageris, Ben I

    2016-01-01

    The mechanism and the type of hearing loss induced by cochlear implants are mostly unknown. Therefore, this study evaluated the impact and type of hearing loss induced by each stage of cochlear implantation surgery in an animal model. Original basic research animal study. The study was conducted in a tertiary, university-affiliated medical center in accordance with the guidelines of the Institutional Animal Care and Use Committee. Cochlear implant electrode array was inserted via the round window membrane in 17 ears of 9 adult-size fat sand rats. In 7 ears of 5 additional animals round window incision only was performed, followed by patching with a small piece of periosteum (control). Hearing thresholds to air (AC) and bone conduction (BC), clicks, 1 kHz and 6 kHz tone bursts were measured by auditory brainstem evoked potential, before, during each stage of surgery and one week post-operatively. In addition, inner ear histology was performed. The degree of hearing loss increased significantly from baseline throughout the stages of cochlear implantation surgery and up to one week after (plosses were found for 1-kHz and 6-kHz frequencies. The hearing loss was not associated with significant changes in inner ear histology. Hearing loss following cochlear implantation in normal hearing animals is progressive and of mixed type, but mainly conductive. Changes in the inner-ear mechanism are most likely responsible for the conductive hearing loss. Copyright © 2016 Elsevier Inc. All rights reserved.

  16. Temporal and spectral contributions to musical instrument identification and discrimination among cochlear implant users

    Institute of Scientific and Technical Information of China (English)

    Sandra M. Prentiss; David R. Friedland; Tanner Fullmer; Alison Crane; Timothy Stoddard; Christina L. Runge

    2016-01-01

    Objective:To investigate the contributions of envelope and fine-structure to the perception of timbre by cochlear implant (CI) users as compared to normal hearing (NH) lis-teners. Methods: This was a prospective cohort comparison study. Normal hearing and cochlear implant patients were tested. Three experiments were performed in sound field using musical notes altered to affect the characteristic pitch of an instrument and the acoustic envelope. Experiment 1 assessed the ability to identify the instrument playing each note, while experi-ments 2 and 3 assessed the ability to discriminate the different stimuli. Results:Normal hearing subjects performed better than CI subjects in all instrument identifi-cation tasks, reaching statistical significance for 4 of 5 stimulus conditions. Within the CI pop-ulation, acoustic envelope modifications did not significantly affect instrument identification or discrimination. With envelope and pitch cues removed, fine structure discrimination perfor-mance was similar between normal hearing and CI users for the majority of conditions, but some specific instrument comparisons were significantly more challenging for CI users. Conclusions:Cochlear implant users perform significantly worse than normal hearing listeners on tasks of instrument identification. However, cochlear implant listeners can discriminate differences in envelope and some fine structure components of musical instrument sounds as well as normal hearing listeners. The results indicated that certain fine structure cues are important for cochlear implant users to make discrimination judgments, and therefore may affect interpretation toward associating with a specific instrument for identification.

  17. Across-frequency combination of interaural time difference in bilateral cochlear implant listeners

    Directory of Open Access Journals (Sweden)

    Antje eIhlefeld

    2014-03-01

    Full Text Available The current study examined how cochlear implant (CI listeners combine temporally interleaved envelope-ITD information across two sites of stimulation. When two cochlear sites jointly transmit ITD information, one possibility is that CI listeners can extract the most reliable ITD cues available. As a result, ITD sensitivity would be sustained or enhanced compared to single-site stimulation. Alternatively, mutual interference across multiple sites of ITD stimulation could worsen dual-site performance compared to listening to the better of two electrode pairs. Two experiments used direct stimulation to examine how CI users can integrate ITDs across two pairs of electrodes. Experiment 1 tested ITD discrimination for two stimulation sites using 100-Hz sinusoidally modulated 1000-pps-carrier pulse trains. Experiment 2 used the same stimuli ramped with 100 ms windows, as a control condition with minimized onset cues. For all stimuli, performance improved monotonically with increasing modulation depth. Results show that when CI listeners are stimulated with electrode pairs at two cochlear sites, sensitivity to ITDs was similar to that seen when only the electrode pair with better sensitivity was activated. None of the listeners showed a decrement in performance from the worse electrode pair. This could be achieved either by listening to the better electrode pair or by truly integrating the information across cochlear sites.

  18. Comparison of Persian Simple Vowels Production in Cochlear Implanted Children Based on Implantation Age

    Directory of Open Access Journals (Sweden)

    Peiman Zamani

    2008-07-01

    Full Text Available Objective: Age at implantation is one of the most important factors in improving speech and language skills in children with cochlear implants. Moreover, good vowel articulation is very important in the speech. So, the purpose of this research was to determine whether age at cochlear implantation influences the production of Persian simple vowels when cochlear implantation is undertaken below the age of 2 years as compared with cochlear implantation later in life. Materials & Methods: This research was a comparative and cross-sectional study. Based on inclusive and exclusive criteria (i.e., have physical and mental health, monolingual or bilingual, have 9±1 months post-surgery rehabilitation, no hearing handicapped parents and no medical problems history, 140 children who cochlear implanted in Amir-Alam and Hazrate Rasool hospital of Tehran city were selected by convenient sampling and assigned to two groups, children implanted under the age of 2 years and those implanted above the age of 2 years Also 238 normally hearing children were selected for control group by randomized sampling. The first and second formant frequency (F1 & F2 of the Persian simple vowels /i, e, æ, a, o, u/ were evaluated by the version of 1.2 of SFSwin software. Data were analyzed by Independent T test. Results: The findings indicated that there were significant differences between two groups in the mean of F2/i/ (P=0.046, F1/e/ (P=0.011, F2/e/ (P=0.005, F2/æ/ (P=0.039, F2/a/ (P=0.012, F2/o/ (P=0.012 and F2/u/ (P=0.006, but there was no significant difference between then in the mean of F1/i/, F1/æ/, F2/a/, F1/o/, F1/u/ (P>0.05. According to these results, no significant difference was seen between normal group and children who received their cochlear implants under the age of 2 years in the mean of variables (P>0.05. Conclusion: Observing significant differences in the quality of the production of Persian simple vowels between children implanted under the age of 2

  19. Evidence of echoic memory with a multichannel cochlear prosthesis.

    Science.gov (United States)

    Jerger, S; Watkins, M J

    1988-10-01

    Short-term memory was examined in a subject with a multichannel cochlear prosthesis. Serial recall for lists of digits revealed what are widely regarded as the principal hallmarks of echoic memory, namely the recency effect and the suffix effect. Thus, probability of recall increased for the last one or two digits, except when a nominally irrelevant but spoken item was appended to the to-be-remembered list. It appears, therefore, that a multichannel cochlear implant can give rise to not only the perception of, but also an echoic memory for, speech. As with normal subjects, the suffix effect did not occur with a nonspeech suffix, implying that the echoic memory from the prosthesis shows normal sensitivity to the distinction between speech and nonspeech.

  20. Libyan cochlear implant programme: achievements, difficulties, and ...

    African Journals Online (AJOL)

    Data relating to the patients who received cochlear implantation at Tripoli Medical Centre between October 2007 and February 2010 were analysed. Implant operations were performed on 37 patients. All patients received Med-El SONATATI100 devices. Thirty-four (91.9%) of these patients were children, whilst three (8.1%) ...

  1. Classification and Current Management of Inner Ear Malformations

    Directory of Open Access Journals (Sweden)

    Levent Sennaroğlu

    2017-10-01

    Full Text Available Morphologically congenital sensorineural hearing loss can be investigated under two categories. Majority of the congenital hearing loss (80% are membranous malformations. Here the pathology involves inner ear hair cells. There is no gross bony abnormality and therefore, in these cases, high resolution computerized tomography and MRI of the temporal bone reveal normal findings. Remaining 20% have various malformations involving the bony labyrinth and therefore, can be radiologically demonstrated by CT and MRI. The latter group involves surgical challenges as well as problems in decision making. Some cases may be managed by hearing aid, some need cochlear implantation while some cases are candidates for an auditory brainstem implantation. During cochlear implantation, there may be facial nerve abnormalities, cerebrospinal fluid leakage, electrode misplacement or difficulty in finding the cochlea itself. During the surgery for inner ear malformations, surgeon must be ready to modify the surgical approach or choose special electrodes for surgery. In the present review article inner ear malformations are classified according to the differences observed in the cochlea. Hearing and language outcome after various implantation methods is closely related to the status of cochlear nerve and a practical classification of the cochlear nerve deficiency is also provided

  2. Noninvasive transcranial stimulation of rat abducens nerve by focused ultrasound.

    Science.gov (United States)

    Kim, Hyungmin; Taghados, Seyed Javid; Fischer, Krisztina; Maeng, Lee-So; Park, Shinsuk; Yoo, Seung-Schik

    2012-09-01

    Nonpharmacologic and nonsurgical transcranial modulation of the nerve function may provide new opportunities in evaluation and treatment of cranial nerve diseases. This study investigates the possibility of using low-intensity transcranial focused ultrasound (FUS) to selectively stimulate the rat abducens nerve located above the base of the skull. FUS (frequencies of 350 kHz and 650 kHz) operating in a pulsed mode was applied to the abducens nerve of Sprague-Dawley rats under stereotactic guidance. The abductive eyeball movement ipsilateral to the side of sonication was observed at 350 kHz, using the 0.36-msec tone burst duration (TBD), 1.5-kHz pulse repetition frequency (PRF), and the overall sonication duration of 200 msec. Histologic and behavioral monitoring showed no signs of disruption in the blood brain barrier (BBB), as well as no damage to the nerves and adjacent brain tissue resulting from the sonication. As a novel functional neuro-modulatory modality, the pulsed application of FUS has potential for diagnostic and therapeutic applications in diseases of the peripheral nervous system. Copyright © 2012 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  3. Cochlear implant: Speech and language development in deaf and hard of hearing children following implantation

    Directory of Open Access Journals (Sweden)

    Ostojić Sanja

    2011-01-01

    Full Text Available Bacground/Aim. Almost 200 cochlear implantations were done in the four centers (two in Belgrade, per one in Novi Sad and Niš in Serbia from 2002 to 2009. Less than 10% of implantees were postlingually deaf adults. The vast majority, i.e. 90% were pre- and perilingually profoundly deaf children. The aim of this study was to assess the influence of improved auditory perception due to cochlear implantation on comprehension of abstract words in children as compared with hearing impaired children with conventional hearing aids and normal hearing children. Methods. Thirty children were enrolled in this study: 20 hearing impaired and 10 normal hearing. The vocabulary test was used. Results. The overall results for the whole test (100 words showed a significant difference in favor of the normal hearing as compared with hearing impaired children. The normal hearing children successfully described or defined 77.93% of a total of 100 words. Success rate for the cochlear implanted children was 26.87% and for the hearing impaired children with conventional hearing aids 20.32%. Conclusion. Testing for abstract words showed a statistically significant difference between the cochlear implanted and the hearing impaired children with hearing aids (Mann- Whitney U-test, p = 0.019 implying considerable advantage of cochlear implants over hearing aids regarding successful speech development in prelingually deaf children.

  4. Breaking the sound barrier: exploring parents' decision-making process of cochlear implants for their children.

    Science.gov (United States)

    Chang, Pamara F

    2017-08-01

    To understand the dynamic experiences of parents undergoing the decision-making process regarding cochlear implants for their child(ren). Thirty-three parents of d/Deaf children participated in semi-structured interviews. Interviews were digitally recorded, transcribed, and coded using iterative and thematic coding. The results from this study reveal four salient topics related to parents' decision-making process regarding cochlear implantation: 1) factors parents considered when making the decision to get the cochlear implant for their child (e.g., desire to acculturate child into one community), 2) the extent to which parents' communities influence their decision-making (e.g., norms), 3) information sources parents seek and value when decision-making (e.g., parents value other parent's experiences the most compared to medical or online sources), and 4) personal experiences with stigma affecting their decision to not get the cochlear implant for their child. This study provides insights into values and perspectives that can be utilized to improve informed decision-making, when making risky medical decisions with long-term implications. With thorough information provisions, delineation of addressing parents' concerns and encompassing all aspects of the decision (i.e., medical, social and cultural), health professional teams could reduce the uncertainty and anxiety for parents in this decision-making process for cochlear implantation. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. Comparison of the fastest regenerating motor and sensory myelinated axons in the same peripheral nerve

    DEFF Research Database (Denmark)

    Moldovan, Mihai; Sørensen, Jesper; Krarup, Christian

    2006-01-01

    Functional outcome after peripheral nerve regeneration is often poor, particularly involving nerve injuries far from their targets. Comparison of sensory and motor axon regeneration before target reinnervation is not possible in the clinical setting, and previous experimental studies addressing...... the question of differences in growth rates of different nerve fibre populations led to conflicting results. We developed an animal model to compare growth and maturation of the fastest growing sensory and motor fibres within the same mixed nerve after Wallerian degeneration. Regeneration of cat tibial nerve...... after crush (n = 13) and section (n = 7) was monitored for up to 140 days, using implanted cuff electrodes placed around the sciatic and tibial nerves and wire electrodes at plantar muscles. To distinguish between sensory and motor fibres, recordings were carried out from L6-S2 spinal roots using cuff...

  6. Different Perception of Musical Stimuli in Patients with Monolateral and Bilateral Cochlear Implants

    Science.gov (United States)

    Maglione, Anton Giulio; Leone, Carlo Antonio; Grassia, Rosa; Mosca, Franco; Colosimo, Alfredo; Malerba, Paolo

    2014-01-01

    The aim of the present study is to measure the perceived pleasantness during the observation of a musical video clip in a group of cochlear implanted adult patients when compared to a group of normal hearing subjects. This comparison was performed by using the imbalance of the EEG power spectra in alpha band over frontal areas as a metric for the perceived pleasantness. Subjects were asked to watch a musical video clip in three different experimental conditions: with the original audio included (Norm), with a distorted version of the audio (Dist), and without the audio (Mute). The frontal EEG imbalance between the estimated power spectra for the left and right prefrontal areas has been calculated to investigate the differences among the two populations. Results suggested that the perceived pleasantness of the musical video clip in the normal hearing population and in the bilateral cochlear implanted populations has similar range of variation across the different stimulations (Norm, Dist, and Mute), when compared to the range of variation of video clip's pleasantness for the monolateral cochlear implanted population. A similarity exists in the trends of the perceived pleasantness across the different experimental conditions in the mono- and bilaterally cochlear implanted patients. PMID:25180046

  7. Electrophysiology of Cranial Nerve Testing: Spinal Accessory and Hypoglossal Nerves.

    Science.gov (United States)

    Stino, Amro M; Smith, Benn E

    2018-01-01

    Multiple techniques have been developed for the electrodiagnostic evaluation of cranial nerves XI and XII. Each of these carries both benefits and limitations, with more techniques and data being available in the literature for spinal accessory than hypoglossal nerve evaluation. Spinal accessory and hypoglossal neuropathy are relatively uncommon cranial mononeuropathies that may be evaluated in the outpatient electrodiagnostic laboratory setting. A review of available literature using PubMed was conducted regarding electrodiagnostic technique in the evaluation of spinal accessory and hypoglossal nerves searching for both routine nerve conduction studies and repetitive nerve conduction studies. The review provided herein provides a resource by which clinical neurophysiologists may develop and implement clinical and research protocols for the evaluation of both of these lower cranial nerves in the outpatient setting.

  8. Educational, employment, and social participation of young adult graduates from the paediatric Southern Cochlear Implant Programme, New Zealand.

    Science.gov (United States)

    Goh, Terence; Bird, Philip; Pearson, John; Mustard, Jill

    2016-01-01

    The purpose of this study is to observe the education and vocational achievements and social participation of cochlear implant recipients as they graduate from a paediatric cochlear implant programme and identify any significant associations that might exist. This study identified 56 patients from the Southern Cochlear Implant Programme (SCIP) who received cochlear implants before the age of 19 (paediatric) and are now over the age of 19 (adult). A questionnaire investigated their education, employment, and identity with the hearing and deaf communities. Also included were the satisfaction with life scale and Hearing Participation Scale (HPS). Subjects ranged in age from 19 to 32. Twenty-six patients responded to the questionnaire, including one non-user. Twenty identified strongly or very strongly with the hearing community. There was weak evidence of a linear association between strong identity with the hearing community and a higher HPS score. No other statistically significant associations were detected. Interestingly, 12 out of 26 participants found employment through family. Positive outcome trends in education and employment were seen in this study although no statistical significance was achieved. There is a strong bias for those who use their cochlear implants regularly, and there are no data available for those who do not use their cochlear implants for comparison as only one non-user completed the survey, despite efforts to include this group. This study shows that there is perceived benefit in implantation for patients who use it regularly but further research is needed with a more diverse group of cochlear implant recipients.

  9. Efeitos do potencial de ação neural sobre a percepção de fala em usuários de implante coclear Influence of evoked compound action potential on speech perception in cochlear implant users

    Directory of Open Access Journals (Sweden)

    Mariana Cardoso Guedes

    2007-08-01

    Full Text Available O Potencial de Ação Composto Evocado Eletricamente reflete a atividade do nervo auditivo, podendo ser registrado através dos eletrodos do implante coclear. A determinação dos elementos neurais estimuláveis pode contribuir para explicar a variabilidade de desempenho entre indivíduos implantados. OBJETIVO: Comparar o desempenho nos testes de percepção da fala entre pacientes que apresentaram e que não apresentaram potencial de ação composto evocado eletricamente no momento intra-operatório. MATERIAL E MÉTODO: Estudo prospectivo no qual 100 indivíduos usuários do implante coclear Nucleus 24 foram divididos em dois grupos de acordo com a presença ou ausência do potencial de ação intra-operatório. Após 6 meses de uso do dispositivo, os resultados dos testes de percepção de fala foram comparados entre os grupos. RESULTADOS: O potencial foi observado em 72% dos pacientes. A percepção no teste de frases em formato aberto foi melhor nos indivíduos com presença de potencial (média 82,8% contra 41,0%, p = 0,005. Houve associação entre ausência do potencial e etiologia da surdez por meningite. CONCLUSÃO: Ausência de potencial neural intraoperatório esteve associada ao pior desempenho na percepção da fala e à etiologia da surdez por meningite. Por outro lado, a presença do potencial de ação intraoperatório sugere ótimo prognóstico.Electrically Evoked Compound Action Potential is a measure of synchronous cochlear nerve fibers activity elicited by electrical stimulation of the cochlear implant. The electrophysiological nerve responses may contribute to explain the variability in individual performance of cochlear implant recipients. AIM: To compare speech perception tests’ performances of cochlear implant users according to the presence or absence of intraoperative neural telemetry responses. MATERIAL AND METHOD: Prospective study design with 100 "Nucleus 24" cochlear implant users divided in two groups according

  10. Environmental Sound Training in Cochlear Implant Users

    Science.gov (United States)

    Shafiro, Valeriy; Sheft, Stanley; Kuvadia, Sejal; Gygi, Brian

    2015-01-01

    Purpose: The study investigated the effect of a short computer-based environmental sound training regimen on the perception of environmental sounds and speech in experienced cochlear implant (CI) patients. Method: Fourteen CI patients with the average of 5 years of CI experience participated. The protocol consisted of 2 pretests, 1 week apart,…

  11. Evaluation of Morphological and Functional Nerve Recovery of Rat Sciatic Nerve with a Hyaff11-Based Nerve Guide

    Directory of Open Access Journals (Sweden)

    K. Jansen

    2006-01-01

    Full Text Available Application of a Hyaff11-based nerve guide was studied in rats. Functional tests were performed to study motor nerve recovery. A withdrawal reflex test was performed to test sensory recovery. Morphology was studied by means of histology on explanted tissue samples. Motor nerve recovery was established within 7 weeks. Hereafter, some behavioral parameters like alternating steps showed an increase in occurence, while others remained stable. Sensory function was observed within the 7 weeks time frame. Nerve tissue had bridged the 10-mm gap within 7 weeks. The average nerve fiber surface area increased significantly in time. In situ degradation of the nerve conduit was fully going on at week 7 and tubes had collapsed by then. At weeks 15 and 21, the knitted tube wall structure was completely surrounded by macrophages and giant cells, and matrix was penetrating the tube wall. We conclude that a Hyaff11-based nerve guide can be used to bridge short peripheral nerve defects in rat. However, adaptations need to be made.

  12. [Facial nerve neurinomas].

    Science.gov (United States)

    Sokołowski, Jacek; Bartoszewicz, Robert; Morawski, Krzysztof; Jamróz, Barbara; Niemczyk, Kazimierz

    2013-01-01

    Evaluation of diagnostic, surgical technique, treatment results facial nerve neurinomas and its comparison with literature was the main purpose of this study. Seven cases of patients (2005-2011) with facial nerve schwannomas were included to retrospective analysis in the Department of Otolaryngology, Medical University of Warsaw. All patients were assessed with history of the disease, physical examination, hearing tests, computed tomography and/or magnetic resonance imaging, electronystagmography. Cases were observed in the direction of potential complications and recurrences. Neurinoma of the facial nerve occurred in the vertical segment (n=2), facial nerve geniculum (n=1) and the internal auditory canal (n=4). The symptoms observed in patients were analyzed: facial nerve paresis (n=3), hearing loss (n=2), dizziness (n=1). Magnetic resonance imaging and computed tomography allowed to confirm the presence of the tumor and to assess its staging. Schwannoma of the facial nerve has been surgically removed using the middle fossa approach (n=5) and by antromastoidectomy (n=2). Anatomical continuity of the facial nerve was achieved in 3 cases. In the twelve months after surgery, facial nerve paresis was rated at level II-III° HB. There was no recurrence of the tumor in radiological observation. Facial nerve neurinoma is a rare tumor. Currently surgical techniques allow in most cases, the radical removing of the lesion and reconstruction of the VII nerve function. The rate of recurrence is low. A tumor of the facial nerve should be considered in the differential diagnosis of nerve VII paresis. Copyright © 2013 Polish Otorhinolaryngology - Head and Neck Surgery Society. Published by Elsevier Urban & Partner Sp. z.o.o. All rights reserved.

  13. Simultaneous Communication and Cochlear Implants in the Classroom?

    NARCIS (Netherlands)

    Blom, H.C.; Marschark, M.

    2015-01-01

    This study was designed to evaluate the potential of simultaneous communication (sign and speech together) to support classroom learning by college students who use cochlear implants (CIs). Metacognitive awareness of learning also was evaluated. A within-subjects design involving 40 implant users

  14. Clinical experience with a novel electromyographic approach to preventing phrenic nerve injury during cryoballoon ablation in atrial fibrillation.

    Science.gov (United States)

    Mondésert, Blandine; Andrade, Jason G; Khairy, Paul; Guerra, Peter G; Dyrda, Katia; Macle, Laurent; Rivard, Léna; Thibault, Bernard; Talajic, Mario; Roy, Denis; Dubuc, Marc; Shohoudi, Azadeh

    2014-08-01

    Phrenic nerve palsy remains the most frequent complication associated with cryoballoon-based pulmonary vein (PV) isolation. We sought to characterize our experience using a novel monitoring technique for the prevention of phrenic nerve palsy. Two hundred consecutive cryoballoon-based PV isolation procedures between October 2010 and October 2013 were studied. In addition to standard abdominal palpation during right phrenic nerve pacing from the superior vena cava, all patients underwent diaphragmatic electromyographic monitoring using surface electrodes. Cryoablation was terminated on any perceived reduction in diaphragmatic motion or a 30% decrease in the compound motor action potential (CMAP). During right-sided ablation, a ≥30% reduction in CMAP amplitude occurred in 49 patients (24.5%). Diaphragmatic motion decreased in 30 of 49 patients and was preceded by a 30% reduction in CMAP amplitude in all. In 82% of cases, this reduction in CMAP amplitude occurred during right superior PV isolation. The baseline CMAP amplitude was 946.5±609.2 mV and decreased by 13.8±13.8% at the end of application. This decrease was more marked in the 33 PVs with a reduction in diaphragmatic motion than in those without (40.9±15.3% versus 11.3±10.5%; Pphrenic nerve palsy persisted beyond the end of the procedure, with all cases recovering within 6 months. Despite the shortened application all veins were isolated. At repeat procedure the right-sided PVs reconnected less frequently than the left-sided PVs in those with phrenic nerve palsy. Electromyographic phrenic nerve monitoring using the surface CMAP is reliable, easy to perform, and offers an early warning to impending phrenic nerve injury. © 2014 American Heart Association, Inc.

  15. Contrast enhancement of the cochlear aqueduct in MR imaging: its frequency and clinical significance

    International Nuclear Information System (INIS)

    Nakamura, T.; Naganawa, S.; Fukatsu, H.; Sakurai, Y.; Ishigaki, T.; Aoki, I.; Ninomiya, A.; Nakashima, T.

    2003-01-01

    There have been no previous reports on contrast enhancement of the cochlear aqueduct in magnetic resonance imaging. The purpose of the present study was to evaluate the frequency and significance of this finding. Thirty-one patients (15 men and 16 women; age range 18-81 years) with otologic symptoms (sudden sensorineural hearing loss, vertigo, or tinnitus) were examined using contrast-enhanced imaging on a 1.5-T MR scanner. The normal ear served as the control. Two radiologists evaluated contrast enhancement in the area of the cochlear aqueduct. Forty-eight of 62 ears (77.4%) showed contrast enhancement of the cochlear aqueduct, but no significant differences in the frequency of contrast enhancement were observed between patients with and patients without vertigo, tinnitus, sensorineural hearing loss, cerebellopontine angle tumors, or a high-riding jugular bulb. In addition, no gender- or age-related differences were noted. Contrast enhancement of the cochlear aqueduct was frequently observed, but the frequency of enhancement in symptomatic ears was not significantly higher than in control ears. The results of this study may prove helpful in avoiding unnecessary examinations and potential diagnostic confusion. (orig.)

  16. Contrast enhancement of the cochlear aqueduct in MR imaging: its frequency and clinical significance

    Energy Technology Data Exchange (ETDEWEB)

    Nakamura, T; Naganawa, S; Fukatsu, H; Sakurai, Y; Ishigaki, T [Department of Radiology, Nagoya University School of Medicine, 65 Tsurumai-cho, 466-8550, Shouwa-ku, Nagoya (Japan); Aoki, I; Ninomiya, A [Medical Systems Company, Toshiba Corporation, Nasu Operations, Otawara-shi, Tochigi (Japan); Nakashima, T [Department of Otorhinolaryngology, Nagoya University School of Medicine, Shouwa-ku, Nagoya (Japan)

    2003-09-01

    There have been no previous reports on contrast enhancement of the cochlear aqueduct in magnetic resonance imaging. The purpose of the present study was to evaluate the frequency and significance of this finding. Thirty-one patients (15 men and 16 women; age range 18-81 years) with otologic symptoms (sudden sensorineural hearing loss, vertigo, or tinnitus) were examined using contrast-enhanced imaging on a 1.5-T MR scanner. The normal ear served as the control. Two radiologists evaluated contrast enhancement in the area of the cochlear aqueduct. Forty-eight of 62 ears (77.4%) showed contrast enhancement of the cochlear aqueduct, but no significant differences in the frequency of contrast enhancement were observed between patients with and patients without vertigo, tinnitus, sensorineural hearing loss, cerebellopontine angle tumors, or a high-riding jugular bulb. In addition, no gender- or age-related differences were noted. Contrast enhancement of the cochlear aqueduct was frequently observed, but the frequency of enhancement in symptomatic ears was not significantly higher than in control ears. The results of this study may prove helpful in avoiding unnecessary examinations and potential diagnostic confusion. (orig.)

  17. Use of superficial peroneal nerve graft for treating peripheral nerve injuries

    Directory of Open Access Journals (Sweden)

    Samuel Ribak

    2016-02-01

    Full Text Available ABSTRACT OBJECTIVE: To evaluate the clinical results from treating chronic peripheral nerve injuries using the superficial peroneal nerve as a graft donor source. METHODS: This was a study on eleven patients with peripheral nerve injuries in the upper limbs that were treated with grafts from the sensitive branch of the superficial peroneal nerve. The mean time interval between the dates of the injury and surgery was 93 days. The ulnar nerve was injured in eight cases and the median nerve in six. There were three cases of injury to both nerves. In the surgery, a longitudinal incision was made on the anterolateral face of the ankle, thus viewing the superficial peroneal nerve, which was located anteriorly to the extensor digitorum longus muscle. Proximally, the deep fascia between the extensor digitorum longus and the peroneal longus muscles was dissected. Next, the motor branch of the short peroneal muscle (one of the branches of the superficial peroneal nerve was identified. The proximal limit of the sensitive branch was found at this point. RESULTS: The average space between the nerve stumps was 3.8 cm. The average length of the grafts was 16.44 cm. The number of segments used was two to four cables. In evaluating the recovery of sensitivity, 27.2% evolved to S2+, 54.5% to S3 and 18.1% to S3+. Regarding motor recovery, 72.7% presented grade 4 and 27.2% grade 3. There was no motor deficit in the donor area. A sensitive deficit in the lateral dorsal region of the ankle and the dorsal region of the foot was observed. None of the patients presented complaints in relation to walking. CONCLUSIONS: Use of the superficial peroneal nerve as a graft source for treating peripheral nerve injuries is safe and provides good clinical results similar to those from other nerve graft sources.

  18. Activity-dependent intracellular Ca2+ transients in unmyelinated nerve fibres of the isolated adult rat vagus nerve.

    Science.gov (United States)

    Wächtler, J; Mayer, C; Grafe, P

    1998-04-01

    Confocal laser scanning microscopy was used to follow changes in the free intracellular calcium concentration ([Ca2+]i) in nerve fibres and adjacent Schwann cells in isolated rat vagus nerves. [Ca2+]i was monitored by the Ca2+-sensitive fluorescent dyes Calcium Green-1 and Fura Red. Intracellular Ca2+ transients were observed during repetitive (1-50 Hz) supramaximal electrical stimulation or by bath application of ATP. Trains of action potentials were more effective at elongated, fibre-like structures of the vagus nerves, whereas ATP-induced Ca2+ transients were found predominantly in regions of Schwann cell bodies. Activity-induced Ca2+ signals were unaffected by pharmacological manipulation of intracellular Ca2+ stores, during long-lasting application of purinergic receptor agonists, or by substitution of extracellular Na+ with Li+. However, they were abolished in the presence of Ca2+-free bathing solution or after the blocking of Ca2+ channels with Cd2+. Ca2+ transients were also observed during Ca2+ action potentials. Such "Ca2+ spikes" were elicited by electrical stimulation in the presence of a combination of tetrodotoxin and K+ channel blockers. These data suggest that voltage-dependent Ca2+ channels, activated during short trains of Na+ action potentials, produce an increase in intra-axonal [Ca2+] of rat vagus nerves. We did not find evidence for activity-dependent Ca2+ transients in the Schwann cells surrounding the unmyelinated axons.

  19. Is All Human Hearing Cochlear?

    Directory of Open Access Journals (Sweden)

    Seyede Faranak Emami

    2013-01-01

    Full Text Available The objective of this cross-sectional study was to investigate the possibility that the saccule may contribute to human hearing. The forty participants included twenty healthy people and twenty other subjects selected from patients who presented with benign paroxysmal positional vertigo to Audiology Department of Hazrat Rasoul Akram hospital (Tehran, Iran. Assessments comprised of audiological evaluations, cervical vestibular evoked myogenic potentials (cVEMPs, recognition of spoken phonemes in white noise (Rsp in wn, and auditory brainstem response to 500 Hz tone burst (ABR500 HZ. Twenty affected ears with decreased vestibular excitability as detected by abnormal cVEMPs revealed decreased scores of Rsp in wn and abnormal findings of ABR500 HZ. Both unaffected and normal ears had normal results. Multiple comparisons of mean values of cVEMPs and ABR500 HZ between three groups were significant (P<0.05, ANOVA. The correlation between RSP in wn and p13 latencies was significant. The peak-to-peak amplitudes showed significant correlation to RSP in wn. The correlation between RSP in wn and the latencies of n23 was significant. In high-level of noisy competing situations, healthy human saccular sensation can mediate the detection of low frequencies and possibly help in cochlear hearing for frequency and intensity discrimination. So, all human hearing is not cochlear.

  20. The cochlear implant and possibilities for narrowing the remaining gaps between prosthetic and normal hearing

    Directory of Open Access Journals (Sweden)

    Blake S. Wilson

    2017-12-01

    Full Text Available Background: The cochlear implant has become the standard of care for severe or worse losses in hearing and indeed has produced the first substantial restoration of a lost or absent human sense using a medical intervention. However, the devices are not perfect and many efforts to narrow the remaining gaps between prosthetic and normal hearing are underway. Objective: To assess the present status of cochlear implants and to describe possibilities for improving them. Results: The present-day devices work well in quiet conditions for the great majority of users. However, not all users have high levels of speech reception in quiet and nearly all users struggle with speech reception in typically noisy acoustic environments. In addition, perception of sounds more complex than speech, such as most music, is generally poor unless residual hearing at low frequencies can be stimulated acoustically in conjunction with the electrical stimuli provided by the implant. Possibilities for improving the present devices include increasing the spatial specificity of neural excitation by reducing masking effects or with new stimulus modes; prudent pruning of interfering or otherwise detrimental electrodes from the stimulation map; a further relaxation in the criteria for implant candidacy, based on recent evidence from persons with high levels of residual hearing and to allow many more people to benefit from cochlear implants; and “top down” or “brain centric” approaches to implant designs and applications. Conclusions: Progress in the development of the cochlear implant and related treatments has been remarkable but room remains for improvements. The future looks bright as there are multiple promising possibilities for improvements and many talented teams are pursuing them. Keywords: Auditory prosthesis, Cochlear implant, Cochlear prosthesis, Deafness, Neural prosthesis