WorldWideScience

Sample records for cobalt-60 point sources

  1. An elevator for cobalt-60 source

    International Nuclear Information System (INIS)

    Tang Zaimin; Liang Donghu

    1990-07-01

    The elevator used for cobalt-60 source is a key device in the irradiation industry. It plays an important role in the safety and control of irradiation operation as well as the utilization rate of radiation source. From 1983 to 1986, Beijing Institute of Nuclear Engineering undertook designing of various size irradiation projects for different uses. Since then a kind of cobalt-60 source elevator suited for the irradiator of wet-source-storage has been chosen. It is reliable in the operation and complete in the function. An automatic control circuit brings the systems of cobalt-60 source elevator into an interlock system which ensures the irradiation operation safety. Besides introducing the structural features and performance of this elevator, the conditions of safety interlocking in raising or lowering the cobalt-60 source is also discussed. The discussion is from the safety viewpoint of operating an irradiator and irradiation technology

  2. Total quality management of cobalt-60 sources

    International Nuclear Information System (INIS)

    Malkoske, G.R.

    1999-01-01

    Total Quality Management of Cobalt-60 sources by a supplier requires a life cycle approach to source management. This covers various aspects, including design, manufacturing, installation, field inspection, source surveillance and return of cobalt-60 sources at the end of their useful life. The Total Quality Management approach demonstrates a strong industry commitment to the beneficial use of gamma technology for industrial irradiation applications in both developed nations and in those nations who are developing their infrastructure and techniques for the beneficial use of this technology. MDS Nordion continues to demonstrate its support and commitment to the industry by developing and implementing state-of-the-art standards for the safe use of cobalt-60 sources

  3. C-188 cobalt-60 sealed source integrity: source monitoring

    International Nuclear Information System (INIS)

    Defalco, G.M.; Shah, V.

    1995-01-01

    The integrity of C-188 cobalt-60 sealed sources used for radiation processing will be a key factor in the continued industrial acceptance and growth of gamma irradiation technology. Given the public's relatively poor understanding of most nuclear topics and the news media's tendency to sensationalize events, it is appropriate for suppliers and users of gamma technology to be vigilant and conservative regarding the application of cobalt-60 sources to industrial purposes. Nordion's recent decision to extend the optional warranty on its C-188 cobalt-60 sealed source from 15 years to 20 years is based on over 30 years of data generated from its on-going SOURCE SURVEILLANCE PROGRAM. This paper presents an overview of the C-188 SOURCE SURVEILLANCE PROGRAM. (author)

  4. Some safety aspects during the replacement of Cobalt-60 sources in teletherapy

    International Nuclear Information System (INIS)

    Milu, C.

    1998-01-01

    Some recent radiation protection problems arose during the replacement of the old Cobalt-60 sources in teletherapy in Romania. There are pointed out the potential radiation risks for the population and the lack of appropriate regulation for the field. (author)

  5. Exposure buildup factors for a cobalt-60 point isotropic source for single and two layer slabs

    International Nuclear Information System (INIS)

    Chakarova, R.

    1992-01-01

    Exposure buildup factors for point isotropic cobalt-60 sources are calculated by the Monte Carlo method with statistical errors ranging from 1.5 to 7% for 1-5 mean free paths (mfp) thick water and iron single slabs and for 1 and 2 mfp iron layers followed by water layers 1-5 mfp thick. The computations take into account Compton scattering. The Monte Carlo data for single slab geometries are approximated by Geometric Progression formula. Kalos's formula using the calculated single slab buildup factors may be applied to reproduce the data for two-layered slabs. The presented results and discussion may help when choosing the manner in which the radiation field gamma irradiation units will be described. (author)

  6. Cobalt-60 production in CANDU power reactors

    International Nuclear Information System (INIS)

    Slack, J.; Norton, J.L.; Malkoske, G.R.

    2003-01-01

    MDS Nordion has been supplying cobalt-60 sources to industry for industrial and medical purposes since 1946. These cobalt-60 sources are used in many market and product segments. The major application is in the health care industry where irradiators are used to sterilize single use medical products. These irradiators are designed and built by MDS Nordion and are used by manufacturers of surgical kits, gloves, gowns, drapes and other medical products. The irradiator is a large shielded room with a storage pool for the cobalt-60 sources. The medical products are circulated through the shielded room and exposed to the cobalt-60 sources. This treatment sterilizes the medical products which can then be shipped to hospitals for immediate use. Other applications for this irradiation technology include sanitisation of cosmetics, microbial reduction of pharmaceutical raw materials and food irradiation. The cobalt-60 sources are manufactured by MDS Nordion in their Cobalt Operations Facility in Kanata. More than 75,000 cobalt-60 sources for use in irradiators have been manufactured by MDS Nordion. The cobalt-60 sources are double encapsulated in stainless steel capsules, seal welded and helium leak tested. Each source may contain up to 14,000 curies. These sources are shipped to over 170 industrial irradiators around the world. This paper will focus on the MDS Nordion proprietary technology used to produce the cobalt-60 isotope in CANDU reactors. Almost 55 years ago MDS Nordion and Atomic Energy of Canada developed the process for manufacturing cobalt-60 at the Chalk River Labs, in Ontario, Canada. A cobalt-59 target was introduced into a research reactor where the cobalt-59 atom absorbed one neutron to become cobalt-60. Once the cobalt-60 material was removed from the research reactor it was encapsulated in stainless steel and seal welded using a Tungsten Inert Gas weld. The first cobalt-60 sources manufactured using material from the Chalk River Labs were used in cancer

  7. Activity distribution of a cobalt-60 teletherapy source

    International Nuclear Information System (INIS)

    Jaffray, D.A.; Munro, P.; Battista, J.J.; Fenster, A.

    1991-01-01

    In the course of quantifying the effect of radiation source size on the spatial resolution of portal images, a concentric ring structure in the activity distribution of a Cobalt-60 teletherapy source has been observed. The activity distribution was measured using a strip integral technique and confirmed independently by a contact radiograph of an identical but inactive source replica. These two techniques suggested that this concentric ring structure is due to the packing configuration of the small 60Co pellets that constitute the source. The source modulation transfer function (MTF) showed that this ring structure has a negligible influence on the spatial resolution of therapy images when compared to the effect of the large size of the 60Co source

  8. Transport of cobalt-60 industrial radiation sources

    Science.gov (United States)

    Kunstadt, Peter; Gibson, Wayne

    This paper will deal with safety aspects of the handling of Cobalt-60, the most widely used industrial radio-isotope. Cobalt-60 is a man-made radioisotope of Cobalt-59, a naturally occurring non radioactive element, that is made to order for radiation therapy and a wide range of industrial processing applications including sterilization of medical disposables, food irradiation, etc.

  9. Preliminary feasibility study on production of cobalt-60 source for industrial irradiation

    International Nuclear Information System (INIS)

    Joo, Po Kook; Park, Kyung Bae; Ahn, Yun Soo; Lee, Jong Tai; Kim, Hark Rho

    1999-05-01

    As there is a high possible demand of industrial Co-60 source in the world market, feasibility study of a project was performed to produce and to export Co-60 sources, utilizing KEPCO's Wolsung NPP for irradiation of cobalt and KAERI's hot-cells for fabrication of cobalt sources. Main concerns of the study were to understand irradiation and fabrication (encapsulation) processes and to examine related technologies, required facilities and equipment. In particular, it was examined intensively if it would be possible to modify facilities around the reactor vessel of Wolsung NPP tp substantiate the related licensing in order to irradiate cobalt in the reactor. It is expected that once, if cooperation scheme with MDS Nordion of Canada is established, main issues such as modification of facilities, related licensing, raw material procurement and technology transfer for high quality product will be solved. In order to review overall feasibility of the project, present status and prospect of the world market was surveyed and various usages of cobalt sources were reviewed with emphasis on possible demand increase per usage. Food poisoning accidents are prevailing worldwide and food irradiation with cobalt sources is considered as a promising measure to prevent them and may bring forth high increase of cobalt sources demand in the world market. Preliminary economic feasibility was studied in conservation, evaluating roughly the investment and the operating cost based on materials from various information sources. (author)

  10. Transport of radioactive source of cobalt-60 for the steel industry

    International Nuclear Information System (INIS)

    Santos, Paulo de Oliveira

    2009-01-01

    Radioactive materials are used in the fields of medicine, industry, research and nuclear power production. The use of radioactive material may involve transportation and this implies in the application of safety measures to the workers, public and the environment. Many types of radioactive material are produced all over the world and some modes of transport are involved. The IAEA regulations are based on the philosophy that radioactive material being transported should be adequately packaged to provide protection against the hazards of the material under all conditions of transport. Some Brazilian steel industries control the levels of liquid steel in continuous casting systems by means of sealed sources of cobalt-60. The Center for Development of Nuclear Technology-CDNT produces several of these sources to meet these industries and these sources must be transported in packages designed and tested as requirements of the rules of carriage of radioactive materials. For the transportation of seven sources of cobalt-60 with total activity of 1 GBq since CDNT to the applicant industries was designed, built and tested a Type A package. The thickness of the shield to meet the surface dose rate and the index of transport was calculated by MCNP (Monte Carlo N-Particle Transport Code-Version 5) and practical values were compatible. The sealed sources of cobalt-60 were tested as to leak through the tightness test conducted according to ISO 9978:1992 (E) and the tests to demonstrate the capability of resistance of packaged under normal conditions of transport were made on the facilities of CDNT. (author)

  11. Development and production of cobalt-60 sources for metallurgical application

    International Nuclear Information System (INIS)

    Oliveira, Paulo Fernando; Valente, Eduardo Sarmento; Maretti Junior, Fausto

    2002-01-01

    The CDTN has developed and produced 60 Co sources to be used in level controllers on continuous ingot casting. The sources used in these systems are sealed with a stainless steel revetment and have an useful life equivalent to one half life of the 60 Co (5.272 years). Each system of continuous ingot casting uses a source with one specified activity and different activation section. The sources have been imported with a very high cost due the special shields used to keep and transport them safety. One of its sources, with initial activity of 148 MBq, after being used for more than 5 years in one factory, was given to CDTN to carry out an activation section studies. After these studies be concluded CDTN/CNEN began the procedures to produce a new source in the IPR-R1 TRIGA Reactor, with an irradiation of one cobalt wire in the maximum flux region of the core. The same metallic cobalt wire was irradiated (10% of total activity), to determinate the necessary irradiation time to obtain the final activation. The CDTN developed too a stainless steel recipient with a aluminum nucleus, to seal and to guarantee the integrity of the source. (author)

  12. Cobalt-60 production in CANDU power reactors

    International Nuclear Information System (INIS)

    Malkoske, G.R.; Norton, J.L.; Slack, J.

    2002-01-01

    MDS Nordion has been supplying cobalt-60 sources to industry for industrial and medical purposes since 1946. These cobalt-60 sources are used in many market and product segments, but are primarily used to sterilize single-use medical products including; surgical kits, gloves, gowns, drapes, and cotton swabs. Other applications include sanitization of cosmetics, microbial reduction of pharmaceutical raw materials, and food irradiation. The technology for producing the cobalt-60 isotope was developed by MDS Nordion and Atomic Energy of Canada Limited (AECL) almost 55 years ago using research reactors at the AECL Chalk River Laboratories in Ontario, Canada. The first cobalt-60 source produced for medical applications was manufactured by MDS Nordion and used in cancer therapy. The benefits of cobalt-60 as applied to medical product manufacturing, were quickly realized and the demand for this radioisotope quickly grew. The same technology for producing cobalt-60 in research reactors was then designed and packaged such that it could be conveniently transferred to a utility/power reactor. In the early 1970's, in co-operation with Ontario Power Generation (formerly Ontario Hydro), bulk cobalt-60 production for industrial irradiation applications was initiated in the four Pickering A CANDU reactors. As the demand and acceptance of sterilization of medical products grew, MDS Nordion expanded its bulk supply by installing the proprietary Canadian technology for producing cobalt-60 in additional CANDU reactors. CANDU is unique among the power reactors of the world, being heavy water moderated and fuelled with natural uranium. They are also designed and supplied with stainless steel adjusters, the primary function of which is to shape the neutron flux to optimize reactor power and fuel bum-up, and to provide excess reactivity needed to overcome xenon-135 poisoning following a reduction of power. The reactor is designed to develop full power output with all of the adjuster

  13. Cobalt-60 production in CANDU reactors

    International Nuclear Information System (INIS)

    Ross, Michel; Lemire, Christian

    2002-01-01

    CANDU reactors can produce cobalt-60 very efficiently and with an interesting return on investment. This paper discusses what is needed to convert a CANDU reactor into a cobalt-60 producer: what are the different phases, the safety studies required, the physical modifications needed, and what is the minimum involvement of the utility owning the plant. The past ten years of experience of Hydro-Quebec as a cobalt-60 producer will be reviewed, including the management of the risk of both incident and electricity generation loss, and including the benefits for the utility and its personnel. Originally a simple metal used for centuries as a pigment, cobalt-59 today is transformed into cobalt-60, a radioactive element of unprecedented value. Well known in medicine for cancer treatment, cobalt-60 is also used to sterilize a wide range of disposable medical products used in hospitals and to sanitize pharmaceutical and cosmetic products. Cobalt-60 is proving to be a new and effective solution, in the food sector, for preserving harvests and controlling food-borne diseases, or to advantageously replace certain gases and chemical products which are suspected of being harmful or carcinogenic. There are also other applications, such as: hardening of some plastics, treatment of sewage sludge and elimination of harmful insect populations. With a half-life of 5,3 years, cobalt-60 is a metal not found in nature. It is a radioactive isotope produced by exposing stable nuclei of cobalt-59 to neutrons. One of the best places to find such an important neutron source is a nuclear reactor. High energy gamma rays are then emitted during the process of radioactive decay, where cobalt-60 seeks again its stable state

  14. Quality and security on the uses of cobalt 60 sources for industrial irradiators

    International Nuclear Information System (INIS)

    Desroches, J.

    1976-01-01

    The construction and operation of industrial irradiators using large quantities of cobalt 60 give rise to an important problem of security. The CEA Radioisotope Department which manufactures and sells sources of Co60 has created an insurance Quality System which insures the maximum of security for the user. (author)

  15. Cobalt-60 and Caesium-137 Gamma Sources; Sources de rayonnement gamma au cobalt-60 et au cesium-137; Gamma-istochniki iz kobal'ta-605 i tseziya-137; Fuentes gamma de cobalto-60 y de cesio-137

    Energy Technology Data Exchange (ETDEWEB)

    Kulish, E E; Fradkin, G M [Academy of Sciences of the USSR, Moscow, Union of Soviet Socialits Republics (Russian Federation)

    1960-07-15

    The paper gives the main technical characteristics of gamma sources produced in the USSR using cobalt-60 and caesium-137 and discusses some of the problems of their production technology. The paper contains information on the radiation spectra of Co{sup 60} and Cs{sup 137} and of the source material from which they are prepared. Data are given on the dependence of the activity of cobalt sources upon the intensity of the neutron beam and the geometrical size of the sample. The yield of caesium by uranium fission is also analyzed. The problem of hermetic sealing of the sources is discussed and a complete nomenclature of all the sources manufactured in the USSR are listed, their size and activity also being indicated. In conclusion a comparison of Co{sup 60} and Cs{sup 137} sources is made. (author) [French] Cette communication expose les caracteristiques techniques fondamentales des sources de rayonnement gamma a base de cobalt-60 et de cesium-137 pro- duites en URSS; on y examine egalement certaines questions relatives a la technologie de leur production. La communication contient des donnees sur la nature du rayonnement des isotopes {sup 60}Co et {sup 137}Cs, ainsi que sur celle des matieres brutes utilisees pour leur preparation. On donne les resultats obtenus lors de l'etude de la variation de l'activite des sources au cobalt en fonction de la valeur du flux de neutrons et des dimensions geometriques de l'echantillon, ainsi que les resultats relatifs a la valeur du rendement en isotopes de cesium lors de la fission des noyaux d'uranium. On etudie ensuite les procedes pour assurer l'hermeticite de ces sources. Suit une nomenclature complete des sources produites en URSS, comportant des indications sur leurs dimensions geometriques et sur les valeurs de leur activite. Enfin, il est procede a une comparaison des sources au {sup 60}Co et au {sup 137}Cs. (author) [Spanish] En este informe se describen las principales caracteristicas tecnicas de las fuentes gamma de

  16. Cobalt 60 gamma irradiation current status, trends and insights

    International Nuclear Information System (INIS)

    Corley, John T.

    1998-01-01

    This paper discusses the current status, trends and insights into the continued, safe use of cobalt 60 gamma irradiation. Also presented are some of the many initiatives undertaken at MDS Nordion. Topics covered include our investment for the future supply of raw materials and the latest news from source production. Briefly presented are the tasks associated with the safe transport of cobalt 60 around the world. Discussed is cobalt 60 usage at the customer site; more specifically maintaining source integrity, source utilization and irradiator design trends. Highlighted are industry trends for North America, Europe and the rest of the world. Finally presented are the challenges and opportunities for the industry. Stressed in the paper is the need to work together

  17. Evaluation of skyshine dose due to gamma-rays from a cobalt-60 irradiation facility

    International Nuclear Information System (INIS)

    Kanazawa, Tamotsu; Okamoto, Shinichi; Ohnishi, Tokuhiro; Tsujii, Yukio

    1991-01-01

    We attempted to evaluate skyshine dose due to gamma-rays from a cobalt-60 irradiation facility. As the first step, the results of measurements and calculations were compared of the skyshine dose due to gamma-rays from the cobalt-60 source of 1.45 PBq set in the No.4 irradiation room of our laboratory. Distances of measuring points from the cobalt source were in the range from 17 m to about 100 m in the site of our office. Calculation was carried out with simplified single scattering method. The calculated values of the skyshine dose were higher than the measured values. For more precise evaluation of the skyshine dose, the following factors are to be considered; the dose rate distribution on the roof above the source and the attenuation of gamma-rays by air. (author)

  18. The cobalt-60 container scanner

    International Nuclear Information System (INIS)

    Jigang, A.; Liye, Z.; Yisi, L.; Haifeng, W.; Zhifang, W.; Liqiang, W.; Yuanshi, Z.; Xincheng, X.; Furong, L.; Baozeng, G.; Chunfa, S.

    1997-01-01

    The Institute of Nuclear Energy Technology (INET) has successfully designed and constructed a container (cargo) scanner, which uses cobalt-60 of 100-300 Ci as radiation source. The following performances of the Cobalt-60 container scanner have been achieved at INET: a) IQI (Image Quality Indicator) - 2.5% behind 100 mm of steel; b) CI (Contrast Indicator) - 0.7% behind 100 mm of steel; c) SP (Steel Penetration) - 240 mm of steel; d) Maximum Dose per Scanning - 0.02mGy; e) Throughput - twenty 40-foot containers per hour. These performances are equal or similar to those of the accelerator scanners. Besides these nice enough inspection properties, the Cobalt-60 scanner possesses many other special features which are better than accelerator scanners: a) cheap price - it will be only or two tenths of the accelerator scanner's; b) low radiation intensity - the radiation protection problem is much easier to solve and a lot of money can be saved on the radiation shielding building; c) much smaller area for installation and operation; d) simple operation and convenient maintenance; e) high reliability and stability. The Cobalt-60 container (or cargo) scanner is satisfied for boundary customs, seaports, airports and railway stations etc. Because of the nice special features said above, it is more suitable to be applied widely. Its high properties and low price will make it have much better application prospects

  19. Cobalt 60 availability for radiation processing

    International Nuclear Information System (INIS)

    Fraser, F.M.

    1986-01-01

    In the last 20 years, the steady and significant growth in the application of radiation processing to industrial sterilization has been seen. The principal application of this technology is the sterilization of disposable medical products, food irradiation, the irradiation of personal care goods and so on. At present, more than 70 million curies of cobalt-60 supplied by Atomic Energy of Canada Ltd. have been used for gamma processing in these applications. This is estimated to be more than 80 % of the total cobalt-60 in service in the world. Commercial food irradiation has an exciting future, and as to the impact of food irradiation on the availability of cobalt-60 over the next ten years, two principal factors must be examined, namely, the anticipated demand for cobalt-60 in all radiation processing applications, and the supply of cobalt-60 to reliably meet the expected demand. As for the cobalt-60 in service today, 90 % is used for the sterilization of disposable medical products, 5 % for food irradiation, and 5 % for other application. The demand for up to 30 million curies of cobalt-60 is expected over the next 10 years. Today, it is estimated that over 150,000 tons of spices, fruit and fish are irradiated. The potential cobalt-60 production could exceed 110 million curies per year. Gamma processing application will demand nearly 50 million curies in 1990. (Kako, I.)

  20. Activation of cobalt 60 in the LVR-15 reactor core

    International Nuclear Information System (INIS)

    Melichar, F.

    1995-12-01

    Cobalt disks were irradiated in the LVR-15 reactor and the relevant cobalt-60 production parameters, particularly the formation rate, were measured. The data were compared with those from previous work by other authors and some discrepancies were found. It is concluded that additional experiments have to be performed in order to obtain reliable data, usable in economic balance assessment with respect to the use of hot chambers for the production of sealed cobalt-60 sources. (P.A.). 4 tabs., 3 refs., 10 annexes

  1. National Low-Level Waste Management Program Radionuclide Report Series: Volume 12, Cobalt-60

    International Nuclear Information System (INIS)

    Adams, J.P.

    1995-06-01

    This report outlines the basic radiological and chemical characteristics of cobalt-60 ( 60 Co) and examines how these characteristics affect the behavior of 60 Co in various environmental media, such as soils, groundwater, plants, animals, the atmosphere, and the human body. Discussions also include methods of 60 Co production, waste types, and waste forms that contain 60 Co. All cobalt atoms contain 27 protons (Z = 27) and various numbers of neutrons (typically N = 27 to 37 neutrons) within the atom's nucleus. There is only one stable isotope of cobalt, namely 59 Co. All other cobalt isotopes, including 60 Co, are radioactive. The radioactive isotopes of cobalt have half-lives ranging from less than a second ( 54 Co-0.19 s) to 5.2 years ( 60 Co). The radioactive isotopes of cobalt are not a normal constituent of the natural environment and are generated as a result of human activities. The primary source of 60 Co in the environment has been low-level radioactive waste material generated as a result of neutron activation of stable 59 Co that is present in the structural components of nuclear reactor vessels. This isotope is also intentionally produced, usually in reactors but also to some degree in accelerators for industrial and medical uses, such as for radiation sources for cancer treatment and nondestructive testing of metals and welds. 60 Co may enter the environment as a result of the activities associated with nuclear reactor operations and decommissioning and when industrial and medical sources are being used, manufactured, or disposed

  2. Preparation of very small point sources for high resolution radiography

    International Nuclear Information System (INIS)

    Case, F.N.

    1976-01-01

    The need for very small point sources of high specific activity 192 Ir, 169 Yb, 170 Tm, and 60 Co in non-destructive testing has motivated the development of techniques for the fabrication of these sources. To prepare 192 Ir point sources for use in examination of tube sheet welds in LMFBR heat exchangers, 191 Ir enriched to greater than 90 percent was melted in a helium blanketed arc to form spheres as small as 0.38 mm in diameter. Methods were developed to form the roughly spherical shaped arc product into nearly symmetrical spheres that could be used for high resolution radiography. Similar methods were used for spherical shaped sources of 169 Yb and 170 Tm. The oxides were arc melted to form rough spheres followed by grinding to precise dimensions, neutron irradiation of the spheres at a flux of 2 to 3 x 10 15 nv, and use of enriched 168 Yb to provide the maximum specific activity. Cobalt-60 with a specific activity of greater than 1100 Ci/g was prepared by processing 59 Co that had been neutron irradiated to nearly complete burnup of the 59 Co target to produce 60 Co, 61 Ni, and 62 Ni. Ion exchange methods were used to separate the cobalt from the nickel. The cobalt was reduced to metal by plating either onto aluminum foil which was dissolved away from the cobalt plate, or by plating onto mercury to prepare amalgam that could be easily formed into a pellet of cobalt with exclusion of the mercury. Both methods are discussed

  3. Ultrasonography-guided cobalt-60 brachytherapy for malignant glioma

    International Nuclear Information System (INIS)

    Sakai, Noboru; Takenaka, Katsunobu; Ueda, Tatsuya

    1989-01-01

    Brachytherapy with cobalt-60 source is reported. In this method it is characterized that the source is inserted interstitially with remote control system by after-loading method via outer catheter (using tandem tube), which was established in the center of residual tumor, using ultrasonography guide with trepanation, or intraoperatively put within the dead space after tumor resection. Six cases of deep-seated and recurrent malignant glioma, were treated with this method. A total dose of 20 to 45 Gy (10 to 15 Gy/day for 2 to 3 days) was delivered to the target. Additionally conventional external irradiation was followed. The effect of cobalt-60 brachytherapy on such tumors were favorable especially for well-circumscribed glioma less than 3 cm on CT scan. (author)

  4. An Economic Analysis of Electron Accelerators and Cobalt-60 for Irradiating Food

    OpenAIRE

    Morrison, Rosanna Mentzer

    1989-01-01

    Average costs per pound of irradiating food are similar for the electron accelerator and cobalt-60 irradiators analyzed in this study, but initial investment costs can vary by $1 million. Irradiation costs range from 0.5 to 7 cents per pound and decrease as annual volumes treated increase. Cobalt-60 is less expensive than electron beams for annual volumes below 50 million pounds. For radiation source requirements above the equivalent of 1 million curies of cobalt-60, electron beams are more e...

  5. National Low-Level Waste Management Program Radionuclide Report Series: Volume 12, Cobalt-60

    Energy Technology Data Exchange (ETDEWEB)

    Adams, J.P.

    1995-06-01

    This report outlines the basic radiological and chemical characteristics of cobalt-60 ({sup 60}Co) and examines how these characteristics affect the behavior of {sup 60}Co in various environmental media, such as soils, groundwater, plants, animals, the atmosphere, and the human body. Discussions also include methods of {sup 60}Co production, waste types, and waste forms that contain {sup 60}Co. All cobalt atoms contain 27 protons (Z = 27) and various numbers of neutrons (typically N = 27 to 37 neutrons) within the atom`s nucleus. There is only one stable isotope of cobalt, namely {sup 59}Co. All other cobalt isotopes, including {sup 60}Co, are radioactive. The radioactive isotopes of cobalt have half-lives ranging from less than a second ({sup 54}Co-0.19 s) to 5.2 years ({sup 60}Co). The radioactive isotopes of cobalt are not a normal constituent of the natural environment and are generated as a result of human activities. The primary source of {sup 60}Co in the environment has been low-level radioactive waste material generated as a result of neutron activation of stable {sup 59}Co that is present in the structural components of nuclear reactor vessels. This isotope is also intentionally produced, usually in reactors but also to some degree in accelerators for industrial and medical uses, such as for radiation sources for cancer treatment and nondestructive testing of metals and welds. {sup 60}Co may enter the environment as a result of the activities associated with nuclear reactor operations and decommissioning and when industrial and medical sources are being used, manufactured, or disposed.

  6. Sci-Thur PM – Brachytherapy 04: Commissioning and Implementation of a Cobalt-60 High Dose Rate Brachytherapy Source

    Energy Technology Data Exchange (ETDEWEB)

    Dysart, Jonathan [Horizon Health Network (Canada)

    2016-08-15

    An Eckert & Ziegler Bebig Co0.A86 cobalt 60 high dose rate (HDR) brachytherapy source was commissioned for clinical use. Long-lived Co-60 HDR sources offer potential logistical and economic advantages over Ir-192 sources, and should be considered for low to medium workload brachytherapy departments where modest increases in treatment times are not a factor. In optimized plans, the Co-60 source provides a similar dose distribution to Ir-192 despite the difference in radiation energy. By switching to Co-60, source exchange frequency can be reduced by a factor of 20, resulting in overall financial savings of more than 50% compared to Ir-192 sources. In addition, a reduction in Physicist QA workload of roughly 200 hours over the 5 year life of the Co-60 source is also expected. These benefits should be considered against the modest increases in average treatment time compared to those of Ir-192 sources, as well as the centre-specific needs for operating room shielding modification.

  7. Transport of Cobalt 60 from the Argentine Nuclear Power Plant in Embalse

    International Nuclear Information System (INIS)

    Lopez Vietri, J.R.

    2011-01-01

    Full text: The purpose of this presentation is to point out some relevant issues related to the transport of cobalt 60 for domestic uses and export from the Argentine Nuclear Power Plant located in Embalse (ENPP). It is remarked that in last 22 years, ENPP produced about 2600 PBq (70 MCi) of Co-60, and that Argentina is the third Co-60 producer, after Canada and Russia. It is mentioned that in Argentina there are facilities which manufacture Zircaloy seamless tubes and reactivity control bars containing cobalt 59 to be used in ENPP, the operation of Candu reactor at ENPP including cobalt-related activities, and the manufacture and commercialization of Co-60 sealed sources. The Argentine Nuclear Regulatory Authority verifies the compliance of nuclear activities with regulatory standards, including those related to the transport of radioactive material. Then, it is described the process for obtaining Co-60 at ENPP with an activity concentration to allow its use in medicine and industry. After that, is considered in detail the type of package used for the transport of Co-60 from ENPP: it is to say, Type B(U) package designs that must be approved by the Competent Authority origin of the design, and they are able to withstand routine, normal and accident conditions of transport, including severe impacts, fires and immersion in water. The overall dimensions of packages are about 1.0 m to 1.5 m diameter by 1.2 m to 1.8 m high, as well as the gross mass could vary from 6500 kg to 9500 kg. Radioactive contents consist of Co-60 sealed sources (called pencils), with an activity range from 8 PBq to 16 PBq. Then, it is considered activities prior to dispatch of Type B(U) packages at ENPP, including the preparation of radioactive contents, packaging and package (labelling and marking) as well as necessary tests and documentation for transport in order to fulfil pertinent requirements of package design operation manual of the package and related standards. Finally, it is pointed

  8. Fission product gamma-ray sources as an alternative to cobalt-60 sources for sewage sludge sterilization

    International Nuclear Information System (INIS)

    Herrnberger, V.R.D.

    1975-01-01

    The sterilization of sewage sludge is now performed successfully using 60 Co gamma-ray sources. The question arises whether more economic gamma-ray sources exist that could replace the 60 Co source. The following types of sources are considered: Spent fuel elements; mixtures of solidified fission products; and isolated solidified fission products such as 134 / 137 Cs. For a particular irradiation plant the specific source costs (S.Fr./Ci) and their contribution to the irradiation costs for 1 m 3 of sewage irradiated to a dose of 250 krad(S.Fr./m 3 ) are determined and compared with the costs of a plant using a 60 Co source. The encapsulation costs and the effect of the gamma absorption of the source are taken into account. Different encapsulation and source management techniques are reviewed to find the most economic for each source type. A spent fuel element irradiation facility is recommended for use either in combination with a sewage water purification plant or as part of a power reactor station where it replaces the storage water pool for the spent fuel elements. Additional source capsules are not envisaged, as long as double-walled source containers are used. The fission product mixtures are enclosed in double-walled capsules of two different forms: Small cylindrical rods and hollow cylinders. For caesium and cobalt cylindrical rods only are used. The main conclusions of the study are that the highest irradiation costs arise from the use of a fission product mixture source. The costs are, however, only 15% above those of a 60 Co plant. To be competitive the flow-rate has to be adapted to the decreasing activity of the source, resulting in a reduction to 20% within ten years of source utilization. The integrated irradiation plant with a spent fuel element source offers irradiation costs comparable with those of a 60 Co plant, if the flow-rate is constant during one year of source utilization. The irradiation costs are reduced to 25% of those of a 60 Co plant

  9. Cobalt Blues The Story of Leonard Grimmett, the Man Behind the First Cobalt-60 Unit in the United States

    CERN Document Server

    Almond, Peter R

    2013-01-01

    For the latter half of the 20th century, cobalt-60 units were the mainstay of radiation treatments for cancer. Cobalt Blues describes the development of the first cobalt-60 unit in the United States and the man behind it, Leonard Grimmett. Conceptually conceived before World War II, it only became possible because of the development of nuclear reactors during the war. Although Grimmett conceived of and published his ideas first, the Canadians built the first units because of the capability of their reactor to produce more suitable cobalt-60 sources. This book tells the story of how Grimmett and others came together at the time that the U S Atomic Energy Agency was pushing the use of radioactivity in medicine. Due to his sudden death, very little information about Grimmett was known until recently, when various documents have come to light, allowing the full story to be told.

  10. Operational Qualification (OQ) Of MINTEC-Sinagama After Cobalt-60 Sources Replenishment

    International Nuclear Information System (INIS)

    Ruzalina Baharin; Hasan Sham; Ahsanulkhaliqin Abdul Wahab

    2014-01-01

    Activity on cobalt-60 sources replenishment at MINTec-Sinagama had been held in May 2014 with total strength of gamma as 440,000 Ci. Therefore, operational qualification (OQ) needs to be done in order to ensure that Sinagama plant is operating well and deliver suitable doses to the customer's products. In this work, three dose mapping exercises were carried out to establish dose distributions and dose reproducibility of plant, which are corresponded to the density of irradiator container (tote) and absorbed dose at normal operation. Dosimeters used were ceric cerous produced by SSDL, Malaysian Nuclear Agency and placed on three planes that represent three-dimensional array. They were located at certain intervals throughout the tote. This paper describes the OQ process and a bit touch on replenishment activity. (author)

  11. Point kernel technique for calculating dose rates due to cobalt-60 hot particles

    International Nuclear Information System (INIS)

    Thornhill, M.J.; McCarthy, J.T.; Morrissette, R.R.; Leach, B.N.

    1989-01-01

    This paper reports on a computer code called BETA that has been developed by health physicists at the Vermont Yankee Nuclear Power Station which accounts for the mass and size of hot particles of Cobalt-60, and therefore corrects the Loevinger-based dose calculation for self-absorption

  12. Effect of antioxidants on thiobarbituric acid reactive substances of mechanically de boned chicken meat irradiated with ionizing radiation: cobalt-60 and electron beam sources

    Energy Technology Data Exchange (ETDEWEB)

    Brito, Poliana de Paula; Azevedo, Heliana de; Pomarico Neto, Walter; Roque, Claudio Vitor; Brusqui, Armando Luiz, E-mail: hgomes@cnen.gov.b, E-mail: pbrito@cnen.gov.b, E-mail: cvroque@cnen.gov.b, E-mail: abrusqui@cnen.gov.b [Brazilian Nuclear Energy Commission (LAPOC/CNEN), Pocos de Caldas, MG (Brazil); Haguiwara, Marcia Mayumi Harada; Miyagusku, Luciana, E-mail: marciamh@ital.gov.b, E-mail: lucianam@ital.gov.b [Food Technology Institute (ITAL), SP (Brazil). Meat Technology Center

    2011-07-01

    Samples of MDCM with skin were divided into three groups: control (without antioxidants), Antioxidant 1 - A1 (0.3% Sodium Polyphosphate and Sodium Erythorbate 0.05%) and Antioxidant 2 - A2 (Rosemary Extract 0.02% and {alpha}-Tocopherol 0.01%). The three batches of samples were divided into nine groups: no antioxidant and non-irradiated (Cn/I), with antioxidant A1 and non-irradiated (A1n/I), with antioxidant A2 and non-irradiated (A2n/I) without antioxidant and irradiated in Cobalt-60 source (CCo), with antioxidant A1 irradiated in Cobalt 60 source (A1Co) with antioxidant A2 irradiated in Cobalt-60 source (A2Co) with antioxidant A1 irradiated in Electron beam (A1Eb) and with antioxidant A2 irradiated in Electron beam (A2Eb). Each 100 g sample was conditioned in a transparent, low density polyethylene oxygen permeable bag, frozen overnight at a temperature of -18 +- 1 deg C in a chamber, and irradiated in this state, maintaining the temperature low with dry ice. The samples were irradiated with a dose of 3.0 kGy, used two sources of radiation: Cobalt-60 (3.1 kGy.h{sup -1}) and electron beam (2.9 kGy.s{sup -1}). After this process, the samples were evaluated during the refrigeration period (2 +- 1 deg C) for 11 days for the following analysis: total psychotropic bacteria count, thiobarbituric acid reactive substances (TBARS). The addition of antioxidants was able to reduce lipid oxidation caused by the irradiation. There were no differences between the radiation sources used in the same parameters. The better antioxidants mixture in the TBARS reducing it was rosemary extract and {alpha}-tocopherol (A2). (author)

  13. Effect of antioxidants on thiobarbituric acid reactive substances of mechanically de boned chicken meat irradiated with ionizing radiation: cobalt-60 and electron beam sources

    International Nuclear Information System (INIS)

    Brito, Poliana de Paula; Azevedo, Heliana de; Pomarico Neto, Walter; Roque, Claudio Vitor; Brusqui, Armando Luiz; Haguiwara, Marcia Mayumi Harada; Miyagusku, Luciana

    2011-01-01

    Samples of MDCM with skin were divided into three groups: control (without antioxidants), Antioxidant 1 - A1 (0.3% Sodium Polyphosphate and Sodium Erythorbate 0.05%) and Antioxidant 2 - A2 (Rosemary Extract 0.02% and α-Tocopherol 0.01%). The three batches of samples were divided into nine groups: no antioxidant and non-irradiated (Cn/I), with antioxidant A1 and non-irradiated (A1n/I), with antioxidant A2 and non-irradiated (A2n/I) without antioxidant and irradiated in Cobalt-60 source (CCo), with antioxidant A1 irradiated in Cobalt 60 source (A1Co) with antioxidant A2 irradiated in Cobalt-60 source (A2Co) with antioxidant A1 irradiated in Electron beam (A1Eb) and with antioxidant A2 irradiated in Electron beam (A2Eb). Each 100 g sample was conditioned in a transparent, low density polyethylene oxygen permeable bag, frozen overnight at a temperature of -18 +- 1 deg C in a chamber, and irradiated in this state, maintaining the temperature low with dry ice. The samples were irradiated with a dose of 3.0 kGy, used two sources of radiation: Cobalt-60 (3.1 kGy.h -1 ) and electron beam (2.9 kGy.s -1 ). After this process, the samples were evaluated during the refrigeration period (2 +- 1 deg C) for 11 days for the following analysis: total psychotropic bacteria count, thiobarbituric acid reactive substances (TBARS). The addition of antioxidants was able to reduce lipid oxidation caused by the irradiation. There were no differences between the radiation sources used in the same parameters. The better antioxidants mixture in the TBARS reducing it was rosemary extract and α-tocopherol (A2). (author)

  14. Nationwide survey of cobalt-60 teletherapy. Final report

    International Nuclear Information System (INIS)

    Thompson, D.L.; Kearly, F.E.; Wyckoff, H.O.; Gitlin, J.N.; Reffit, E.B.; Shangold, E.J.

    1980-08-01

    The Bureau of Radiological Health and the National Bureau of Standards conducted a nationwide survey of cobalt-60 teletherapy facilities to determine their accuracy in delivery of a prescribed dose to a phantom. Participation was obtained from 684 respondents or 75 percent of US facilities. For each cobalt-60 unit the average dose recorded on five dosimeters was within 5 percent of the prescribed value for 83 percent of the respondents and only exceeded a 10 percent difference for 3 percent of the respondents. Sufficient information for reconstruction of dose calculations was available for 87 percent of the participating facilities. Of these reconstructed calculations, 56 percent were within 1 percent of the prescribed dose of 300 rads. The analysis of data from the survey showed that better performance were related to a number of factors. Among these were expressing the machine calibration in terms of dose rate, performing the machine calibration on an annual basis, and correcting for source decay on a monthly basis. Larger facilities achieved better results than smaller facilities when calculating the absorbed dose rate. Also, each 4 machine characteristics (isocentric mounting, short exposure time, high normalized output, and long treatment distance) were related to better performance with regard to both dosimeter readings and calculated doses. Larger facilities were more likely to be using a cobalt-60 unit having those characteristics

  15. Programme of hot points eradication (Co-60) led on French PWR type reactors

    International Nuclear Information System (INIS)

    Rocher, A.; Ridoux, P.; Anthoni, S.; Brun, C.

    1998-01-01

    The question of hot points (pellets rich in cobalt 59 or in cobalt 60 in a PWR type reactor), is studied from the radiation protection point of view. The purpose is to see how to optimize the radiation protection, the elimination of these hot points can bring an improvement. (N.C.)

  16. Dosimetry of normal and wedge fields for a cobalt-60 teletherapy unit

    International Nuclear Information System (INIS)

    Tripathi, U.B.; Kelkar, N.Y.

    1980-01-01

    A simple analytical method for computation of dose distributions for normal and wedge fields is described and the use of the method in planning radiation treatment is outlined. Formulas has been given to compute: (1) depth dose along central axis of cobalt-60 beam, (2) dose to off-axis points, and (3) dose distribution for a wedge field. Good agreement has been found between theoretical and experimental values. With the help of these formulae, the dose at any point can be easily and accurately calculated and radiotherapy can be planned for tumours of very odd shape and sizes. The limitation of the method is that the formulae have been derived for 50% field definition. For cobalt-60 machine having any other field definition, appropriate correction factors have to be applied. (M.G.B.)

  17. PENYERAPAN COBALT-60 DARI AIR OLEH TANAMAN KIAPU (Pistia stratiotes L.)

    OpenAIRE

    Lailatul Nuzzulul Safitri; Poppy Intan Tjahaja; Ida Bagus Made Suryatika

    2015-01-01

    Has conducted research Cobalt-60 radionuclide uptake by plants kiapu (Pistia stratiotes L.) found in many waters. The purpose of the study was to determine the value of the transfer factor on plant kiapu to Cobalt-60 in water. The study was conducted by growing plants on media kiapu gutter water in pots with the height 35 cm and diameter 11,5 cm containing Cobalt-60. The amount of Cobalt - 60 is absorbed and accumulated by the plant parts, i.e. roots and leaves, was observed by measuring the ...

  18. Contamination of steel produced in the Czech Republic by cobalt 60

    International Nuclear Information System (INIS)

    Malatova, I.; Foltanova, S.; Rulik, P.

    1999-01-01

    In recent years, the metal recycling industry has become aware of the presence of radioactive materials in scrap metal. While the problem has historical roots dating to the earliest days of the use of radium, the use of radioactive materials in industrial devices, coupled with incorrect disposal of those devices led to many cases where radioactive sources were unintentionally smelted in the course of recycling. A survey was made of the steel contamination produced during file years 1993 to 1996 in nine steel producing plants. Altogether 721 steel samples were measured by semiconductor gamma spectrometry. In 62% of the samples, no cobalt 60 activity was detected, i.e. the activity was below the minimum significant activity. In 95.5% of the samples, activity concentration of cobalt 60 was below 10 Bq/kg and in 3.4% of the samples, the activity concentration was between 100 and 1000 Bq/kg. The samples were collected according to a scheme which ensured a random choice. In addition, eight samples collected in plants where file investigation was performed were measured, following the melting of contaminated scrap. These samples had activity concentration of cobalt 60 greater than 1000 Bq/kg. (author)

  19. Feasibility Study for Cobalt Bundle Loading to CANDU Reactor Core

    International Nuclear Information System (INIS)

    Park, Donghwan; Kim, Youngae; Kim, Sungmin

    2016-01-01

    CANDU units are generally used to produce cobalt-60 at Bruce and Point Lepreau in Canada and Embalse in Argentina. China has started production of cobalt-60 using its CANDU 6 Qinshan Phase III nuclear power plant in 2009. For cobalt-60 production, the reactor’s full complement of stainless steel adjusters is replaced with neutronically equivalent cobalt-59 adjusters, which are essentially invisible to reactor operation. With its very high neutron flux and optimized fuel burn-up, the CANDU has a very high cobalt-60 production rate in a relatively short time. This makes CANDU an excellent vehicle for bulk cobalt-60 production. Several studies have been performed to produce cobalt-60 using adjuster rod at Wolsong nuclear power plant. This study proposed new concept for producing cobalt-60 and performed the feasibility study. Bundle typed cobalt loading concept is proposed and evaluated the feasibility to fuel management without physics and system design change. The requirement to load cobalt bundle to the core was considered and several channels are nominated. The production of cobalt-60 source is very depend on the flux level and burnup directly. But the neutron absorption characteristic of cobalt bundle is too high, so optimizing design study is needed in the future

  20. Feasibility Study for Cobalt Bundle Loading to CANDU Reactor Core

    Energy Technology Data Exchange (ETDEWEB)

    Park, Donghwan; Kim, Youngae; Kim, Sungmin [KHNP Central Research Institute, Daejeon (Korea, Republic of)

    2016-10-15

    CANDU units are generally used to produce cobalt-60 at Bruce and Point Lepreau in Canada and Embalse in Argentina. China has started production of cobalt-60 using its CANDU 6 Qinshan Phase III nuclear power plant in 2009. For cobalt-60 production, the reactor’s full complement of stainless steel adjusters is replaced with neutronically equivalent cobalt-59 adjusters, which are essentially invisible to reactor operation. With its very high neutron flux and optimized fuel burn-up, the CANDU has a very high cobalt-60 production rate in a relatively short time. This makes CANDU an excellent vehicle for bulk cobalt-60 production. Several studies have been performed to produce cobalt-60 using adjuster rod at Wolsong nuclear power plant. This study proposed new concept for producing cobalt-60 and performed the feasibility study. Bundle typed cobalt loading concept is proposed and evaluated the feasibility to fuel management without physics and system design change. The requirement to load cobalt bundle to the core was considered and several channels are nominated. The production of cobalt-60 source is very depend on the flux level and burnup directly. But the neutron absorption characteristic of cobalt bundle is too high, so optimizing design study is needed in the future.

  1. Cobalt-60 Machines and Medical Linear Accelerators: Competing Technologies for External Beam Radiotherapy.

    Science.gov (United States)

    Healy, B J; van der Merwe, D; Christaki, K E; Meghzifene, A

    2017-02-01

    Medical linear accelerators (linacs) and cobalt-60 machines are both mature technologies for external beam radiotherapy. A comparison is made between these two technologies in terms of infrastructure and maintenance, dosimetry, shielding requirements, staffing, costs, security, patient throughput and clinical use. Infrastructure and maintenance are more demanding for linacs due to the complex electric componentry. In dosimetry, a higher beam energy, modulated dose rate and smaller focal spot size mean that it is easier to create an optimised treatment with a linac for conformal dose coverage of the tumour while sparing healthy organs at risk. In shielding, the requirements for a concrete bunker are similar for cobalt-60 machines and linacs but extra shielding and protection from neutrons are required for linacs. Staffing levels can be higher for linacs and more staff training is required for linacs. Life cycle costs are higher for linacs, especially multi-energy linacs. Security is more complex for cobalt-60 machines because of the high activity radioactive source. Patient throughput can be affected by source decay for cobalt-60 machines but poor maintenance and breakdowns can severely affect patient throughput for linacs. In clinical use, more complex treatment techniques are easier to achieve with linacs, and the availability of electron beams on high-energy linacs can be useful for certain treatments. In summary, there is no simple answer to the question of the choice of either cobalt-60 machines or linacs for radiotherapy in low- and middle-income countries. In fact a radiotherapy department with a combination of technologies, including orthovoltage X-ray units, may be an option. Local needs, conditions and resources will have to be factored into any decision on technology taking into account the characteristics of both forms of teletherapy, with the primary goal being the sustainability of the radiotherapy service over the useful lifetime of the equipment

  2. Cobalt-60 control in Ontario Hydro reactors

    International Nuclear Information System (INIS)

    Lacy, C.S.

    1988-01-01

    This paper discusses the impact of specifying reduced Cobalt-59 in the primary heat transport circuit materials of construction on the radiation fields developed around the primary circuit. An eight-fold reduction in steam generator radiation fields due to Cobalt-60 has been observed for two identical sets of reactors, one with and one without Cobalt-59 control. The comparison is between eight reactors at the Pickering Nuclear Generating Station (PNGS). Units 5 to 8 (PNGS-B) are identical to Units 1 to 4 (PNGS-A) except that PNGS-B has reduced impurity Cobalt-59 in the alloys of construction and a reduced use of stellite. The effects of chemistry control are also discussed

  3. A laboratory and field evaluation of the mobility of cobalt-60/EDTA

    International Nuclear Information System (INIS)

    Jones, T.L.; Gee, G.W.; Kirkham, R.R.; Swanson, J.L.

    1983-01-01

    We have observed a time and soil type dependence in the ability of the organic complexant EDTA to keep cobalt-60 in solution. Test results indicate that short-term adsorption tests lasting 5 days or less can be misleading. In short-term tests using cobalt-60/EDTA and soil from the Hanford site, low sorption in batch tests and high mobility in column tests were observed. During long-term batch test using cobalt-60/EDTA, the percentage of cobalt remaining in solution decreased from 90% after 7 days to less than 10% after 500 days. In laboratory and field column tests where low water flow rates allowed long contact time, virtually no cobalt movement was observed even though in the field test tritium was transported over 4 meters. Long-term batch tests using cobalt-60/EDTA and soil from Savannah River burial grounds showed that cobalt remainin in solution dropped to 30% of the total cobalt added after 5 days and to less than 1% after 15 days. Batch tests using soil from Oak Ridge burial grounds were less dramatic showing cobalt in solution decreasing from 90% after 5 days to 70% after 35 days. The cobalt-60/EDTA complex appears to be dissociating and leaving uncomplexed cobalt which is readily sorbed. The dissociation seems to be rather complete in Hanford and Savannah River soil but limited in the Oak Ridge soil. The implication to waste management is that the potential for transport of cobalt by EDTA may not be as serious at all burial sites as once thought

  4. The role of Cobalt-60 in modern radiation therapy: Dose delivery and image guidance

    Directory of Open Access Journals (Sweden)

    Schreiner L

    2009-01-01

    Full Text Available The advances in modern radiation therapy with techniques such as intensity-modulated radiation therapy and image-guid-ed radiation therapy (IMRT and IGRT have been limited almost exclusively to linear accel-erators. Investigations of modern Cobalt-60 (Co-60 radiation delivery in the context of IMRT and IGRT have been very sparse, and have been limited mainly to computer-modeling and treatment-planning exercises. In this paper, we report on the results of experiments using a tomotherapy benchtop apparatus attached to a conventional Co-60 unit. We show that conformal dose delivery is possible and also that Co-60 can be used as the radiation source in megavoltage computed tomography imaging. These results complement our modeling studies of Co-60 tomotherapy and provide a strong motivation for continuing development of modern Cobalt-60 treatment devices.

  5. Cobalt60 plaques in recurrent retinoblastoma

    Energy Technology Data Exchange (ETDEWEB)

    Fass, D.; McCormick, B.; Abramson, D.; Ellsworth, R. (Department of Radiation Oncology, Memorial Sloan-Kettering Cancer Center, NY, NY (USA))

    1991-08-01

    Cobalt60 plaque irradiation is one treatment option for patients with recurrent retinoblastoma following conventional external beam irradiation (ERT). Tumorocidal doses can be delivered without excessive risk of normal tissue injury. In patients not considered candidates for xenon arc or cryotherapy, 60Co is an alternative to enucleation. Between 1968 and 1987, 85 patients were treated with 60Co plaques, 72 of whom had failed prior ERT. Age at diagnosis ranged from 1 week to 4 years. There are 37 males and 35 females. Seventy-one patients had bilateral disease and one had unilateral. Three patients had both eyes plaqued. Prior ERT ranged from 30 to 70 Gy (mean 4200 Gy). Time from initial therapy to failure ranged from 13 to 60 months. Cobalt plaques of 10 mm, 15 mm, or 10 {times} 15 mm were used depending on tumor size and location. Dose prescribed to the apex of the tumor ranged from 30 to 50 Gy (median 40 Gy) given over 3 to 8 days. Twelve patients had two plaque applications; three patients had three plaque applications. All patients were followed with routine ophthalmoscopic examinations. Follow-up ranged from 2 to 22 years (mean 8.7). Seven patients died of metastatic disease; 10 patients developed non-ocular second tumors. Thirty patients required enucleation. Twenty-two patients had clear tumor progression, two patients had radiation complications, and six patients had a combination of tumor growth and complications. Cobalt60 can salvage eyes in retinoblastoma patients failing ERT. Currently, the authors are using I125 in an attempt to spare normal ocular tissue and reduce subsequent complications.

  6. Cobalt60 plaques in recurrent retinoblastoma

    International Nuclear Information System (INIS)

    Fass, D.; McCormick, B.; Abramson, D.; Ellsworth, R.

    1991-01-01

    Cobalt60 plaque irradiation is one treatment option for patients with recurrent retinoblastoma following conventional external beam irradiation (ERT). Tumorocidal doses can be delivered without excessive risk of normal tissue injury. In patients not considered candidates for xenon arc or cryotherapy, 60Co is an alternative to enucleation. Between 1968 and 1987, 85 patients were treated with 60Co plaques, 72 of whom had failed prior ERT. Age at diagnosis ranged from 1 week to 4 years. There are 37 males and 35 females. Seventy-one patients had bilateral disease and one had unilateral. Three patients had both eyes plaqued. Prior ERT ranged from 30 to 70 Gy (mean 4200 Gy). Time from initial therapy to failure ranged from 13 to 60 months. Cobalt plaques of 10 mm, 15 mm, or 10 x 15 mm were used depending on tumor size and location. Dose prescribed to the apex of the tumor ranged from 30 to 50 Gy (median 40 Gy) given over 3 to 8 days. Twelve patients had two plaque applications; three patients had three plaque applications. All patients were followed with routine ophthalmoscopic examinations. Follow-up ranged from 2 to 22 years (mean 8.7). Seven patients died of metastatic disease; 10 patients developed non-ocular second tumors. Thirty patients required enucleation. Twenty-two patients had clear tumor progression, two patients had radiation complications, and six patients had a combination of tumor growth and complications. Cobalt60 can salvage eyes in retinoblastoma patients failing ERT. Currently, the authors are using I125 in an attempt to spare normal ocular tissue and reduce subsequent complications

  7. C-188 Co-60 sources installation and source rack loading optimization processes in a gamma irradiation facility

    Energy Technology Data Exchange (ETDEWEB)

    Santos, Paulo de S.; Vasquez, Pablo A.S., E-mail: psantos@ipen.br, E-mail: pavsalva@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2017-11-01

    Since 2004, the Multipurpose Gamma Facility at the Nuclear and Energy Research Institute has been providing services on radiation processing for disinfection and sterilization of health care and disposable medical products as well to support research studies on modification of physical, chemical and biological properties of several materials. Recently, there was an increment in irradiation of the Cultural Heritages. This facility uses C-188 double-encapsulated radioactive Cobalt-60 sources known as pencils from manufactures outside of country. The activity of the cobalt sources decays into a stable nickel isotope with a half-life around 5.27 years, which means a loss of 12.3% annually. Then, additional pencils of Cobalt-60 are added periodically to the source rack to maintain the required capacity or installed activity of the facility. The manufacturer makes shipping of the radioactive sources inside a high density container type B(U) , by sea. This one involves many administrative, transport and radiation safety procedures. Once in the facility, the container is opened inside a deep pool water to remove the pencils. The required source geometry of the facility is obtained by loading these source pencils into predetermined diagram or positions in source modules and distributing these modules over the source rack of the facility. The dose variation can be reduced placing the higher activity source pencils near the periphery of the source rack. In this work are presented the procedures for perform the boiling leaching tests applied to the container, the Cobalt-60 sources installation, the loading processes and the source rack loading optimization. (author)

  8. A Vision Controlled Robot to Detect and Collect Fallen Hot Cobalt60 Capsules inside Wet Storage Pool of Cobalt60 Irradiators

    International Nuclear Information System (INIS)

    Solyman, A.E.M.

    2015-01-01

    In a typical irradiator that use radioactive cobalt-60 capsules source is one of the peaceful uses of atomic energy, it originated strategy in terms of its importance in the sterilization of medical products and food processing from bacteria and fungi before being exported. However, there are several well-known problems related to the fall of the cobalt-60 capsules inside the wet storage pool as a result of manufacturing defects, defects welds or a problem occurs in the vertical movement of the radioactive source rack. Therefore it is necessary to study this problem and solve it in a scientific way so as to keep the human as much as possible from radiation exposure, according to the principles of radiation protection and safety issued by the International Atomic Energy Agency. The present work considers the possibility to use a vision based control arm robot to collect fallen hot cobalt-60 capsules inside wet storage pool. A 5-DOF arm robot is designed and vision algorithms are established to pick the fallen capsule on the bottom surface of the storage pool, read the information printed on its edge (cap) and move it to a safe storage place. Two object detection approaches are studied; RGB-based filter and background subtraction technique. Vision algorithms and camera calibration are done using MATLAB/SIMULINK program. Robot arm forward and inverse kinematics are developed and programmed using an embedded micro controller system. Experiments show the validity of the proposed system and prove its success. The collecting process will be done without interference of operators, so radiation safety will be increased. The results showed camera calibration equations accuracy. And also the presence of vibrations in the hands of the movement of the robot and thus were seized motor rotation speed to 10 degrees per second to avoid these vibrations.This scientific application keeps the operators as much as possible from radiation exposure so it leads to increase radiation

  9. Key technology studies of GY-20 and GY-40 High-capacity cobalt-60 transport casks

    International Nuclear Information System (INIS)

    Liu Huifang; Zhang Xin

    2012-01-01

    GY-20 and GY-40 high-capacity cobalt-60 transport casks are used to transport cobalt-60 industrial irradiators and cobalt-60 bundles. The radioactive contents have special features of high-activity and high residual heat, so only a few countries such as Canada, England and Russia have design capacity. The key technologies and corresponding solutions were studied for the design and manufacture of the cask taking into account the structural, thermal, mechanics and shield requests. A series of tests prove that the cask structure design, design criteria for lead coating structure and quality control measurements are reasonable and effective, and the cask shield integrity can be ensured for all conditions. The casks have ability to transport high-activity sealed sources safely, and the design of cask satisfies the requirement of design code and standard. It can provide reference for other B type package. (authors)

  10. Economics of gamma processing in cobalt-60 irradiation facilities

    International Nuclear Information System (INIS)

    Gay, H. G.; Kotler, J. G.

    1985-01-01

    Gamma processing by cobalt-60 is well established. However, since irradiation of food is relatively new from the commercial point of view, it is important to assess costs of gamma irradiation in the context of food processing. Five different types of AECL-RCC irradiation equipment are examined in terms of their throughputs, and capital and operating costs. Using these figures, costs of irradiation of nine types of food products are presented. In general, these represent about 2-10% of the wholesale cost of these products

  11. Cobalt 60 commercial irradiation facilities

    International Nuclear Information System (INIS)

    West, G.

    1985-01-01

    The advantage of using cobalt 60 for ionizing treatment is that it has excellent penetration. Gamma plants are also very efficient, in as much as there is very little mechanical or electrical equipment in a gamma irradiation facility. The average efficiency of a gamma plant is usually around 95% of all available processing time

  12. Cobalt source calibration

    International Nuclear Information System (INIS)

    Rizvi, H.M.

    1999-01-01

    The data obtained from these tests determine the dose rate of the two cobalt sources in SRTC. Building 774-A houses one of these sources while the other resides in room C-067 of Building 773-A. The data from this experiment shows the following: (1) The dose rate of the No.2 cobalt source in Building 774-A measured 1.073 x 10 5 rad/h (June 17, 1999). The dose rate of the Shepherd Model 109 Gamma cobalt source in Building 773-A measured 9.27 x 10 5 rad/h (June 25, 1999). These rates come from placing the graduated cylinder containing the dosimeter solution in the center of the irradiation chamber. (2) Two calibration tests in the 774-A source placed the graduated cylinder with the dosimeter solution approximately 1.5 inches off center in the axial direction. This movement of the sample reduced the measured dose rate 0.92% from 1.083 x 10 5 rad/h to 1.073 x 10 5 rad/h. and (3) A similar test in the cobalt source in 773-A placed the graduated cylinder approximately 2.0 inches off center in the axial direction. This change in position reduced the measured dose rate by 10.34% from 1.036 x 10 6 to 9.27 x 10 5 . This testing used chemical dosimetry to measure the dose rate of a radioactive source. In this method, one determines the dose by the chemical change that takes place in the dosimeter. For this calibration experiment, the author used a Fricke (ferrous ammonium sulfate) dosimeter. This solution works well for dose rates to 10 7 rad/h. During irradiation of the Fricke dosimeter solution the Fe 2+ ions ionize to Fe 3+ . When this occurs, the solution acquires a slightly darker tint (not visible to the human eye). To determine the magnitude of the change in Fe ions, one places the solution in an UV-VIS Spectrophotometer. The UV-VIS Spectrophotometer measures the absorbency of the solution. Dividing the absorbency by the total time (in minutes) of exposure yields the dose rate

  13. Set of devices for producing radioactive 60Co-sources

    International Nuclear Information System (INIS)

    Eichhorn, P.; Tobisch, F.

    1982-01-01

    A set of devices for producing radioactive 60 Co-sources was developed. A single source has a radioactivity of 445x10 10 GBq. It consists of a double envelope of stainless steel filled with a mixture of small pieces of cobalt and stainless steel wire. The diameter of a source is 11 mm; the length 80 mm. Cobalt wires of different radioactivity with a length of about 110 mm and 0,8 mm diameter are the raw material. The set is located in a hot cell. Construction, functions and operation of the set are described in detail. (author)

  14. New avenues in cobalt-60 production at Ontario Hydro

    International Nuclear Information System (INIS)

    Mylvaganam, C.K.; Ronchka, R.A.

    1990-01-01

    Ontario Hydro produces cobalt-60 in the control rods of twelve power reactors. These reactors have a typical flux of 2 x 10 14 neutrons/cm 2 /s, making them efficient producers of cobalt-60. Current annual production is 45 million curies. Since the primary function of these reactors is the production of electricity, their flexibility to meet the needs of commercial cobalt production by the control rod route is limited. Ontario Hydro is therefore developing innovative production techniques, making use of the CANDU reactor's unique ability to be fuelled on-power. These techniques will enable production to better respond to the market's requirements for quantity and specific activity. As it is supplementary to control rod production, annual supply could potentially reach 165 million curies. (author)

  15. HAW simulation experiments with cobalt-60 radiation sources in the Asse salt mine

    International Nuclear Information System (INIS)

    Rothfuchs, T.; Wieczorek, K.; Feddersen, H.K.

    1986-01-01

    The report describes the experimental work and the measured data of the joint German-American project for the HAW simulation experiment with cobalt-60 radiation sources in the Asse salt mine, covering the period up to the end of the third quarter 1986. The experiment is intended to yield information on the synergistic effects of heat and ionizing radiation on the salt rock under representative waste repository conditions. The investigations aim at the migration, release, and radiolytic decomposition of the water and gas components in the rock salt, and at the thermally induced strain and deformation processes. In addition, corrosion tests are planned to be made on various container test materials, and analyses of salt rock core samples for assessing the effect of heat and radiation on the rock. The report in hand presents all data obtained during the experiment. The results of the subsequent evaluation and verification studies will be presented in another report, the programme being given in an annex to the report in hand. (orig./RB) [de

  16. Research about combination of Gamma Knife and cobalt-60 radiation therapy to treat hypophysoma

    International Nuclear Information System (INIS)

    Xing Yueming; Zhao Xinping; Song Xiang; Wu Wei; Huang Bai

    2003-01-01

    Objective: To probe the therapeutic effectiveness of combination of Gamma Knife and cobalt-60 radiotherapy. Methods: 80 Hypophysoma patients who have been randomly grouped into two groups. Combination of Gamma Knife and cobalt-60 radiotherapy group and single Gamma knife group. Results: The therapeutic effectiveness of combination of Gamma Knife and cobalt-60 radiation therapy group was higher than that of single Gamma Knife group. Conclusion: The hospital that treat Hypophysoma with single Gamma Knife should add cobalt-60 radiotherapy in order to increase the local Hypophysoma dose

  17. The development of 60Co γ knife therapy sources

    International Nuclear Information System (INIS)

    Wu Rihua; Li Xingyi; Wu Guihua; Xia Bing; Zhang Jirong; Chen Tieguang

    2001-01-01

    60 Co γ gamma knife source is a kernel unit of γ knife therapy equipment. It has small active core, high specific activity, narrow half dark area, best focus form, long use period. The research of 60 Co γ knife sources are presented. Specifications of γ knife sources, technical parameters, safety performance, structure feature, procedure and quality control during research are discussed. 60 Co γ source consists of high specific activity cobalt pellets and double stainless steel sealed by argon arc welding. Its safety performance, surface contamination and leakage testing meet the requirements of GB 4075 and GB 4076

  18. Determination of disintegration rates of a 60Co point source and volume sources by the sum-peak method

    International Nuclear Information System (INIS)

    Kawano, Takao; Ebihara, Hiroshi

    1990-01-01

    The disintegration rates of 60 Co as a point source (<2 mm in diameter on a thin plastic disc) and volume sources (10-100 mL solutions in a polyethylene bottle) are determined by the sum-peak method. The sum-peak formula gives the exact disintegration rate for the point source at different positions from the detector. However, increasing the volume of the solution results in enlarged deviations from the true disintegration rate. Extended sources must be treated as an amalgam of many point sources. (author)

  19. Biological fate of cobalt-60 released during the corrosion of neutron-activated stanless steel in seawater

    International Nuclear Information System (INIS)

    Young, J.S.

    1982-03-01

    Passing seawater over radioactive Type 347 stainless steel in a sediment/seawater laboratory system and exposing marine animals to this environment provided information on the bioaccumulation of 60 Co from radioactive structural material. Exposure of marine organisms to radioactive corrosion products and directly to radioactive stainless steel in seawater simulated some of the possible conditions which could arise from the deposition of radioactive stainless steel on the ocean floor. Detectable levels of 60 Co in marine animals were not observed on a short term basis (5 weeks). Longterm (13 months) exposure of marine animals in a sediment/seawater system resulted in 60 Co bioaccumulation. The specific activity of 60 Co in the organisms was as much as one million times less than that initially present in the radioactive stainless steel. This was due to the dilution of 60 Co by stable cobalt in the seawater, sediments and organisms. As expected the 60 Co specific activity of the organisms never increased above that of the radioactive source. This is because 60 Co is chemicaly indistinguishable from stable Co. Increasing 60 Co concentration factors with decreasing 60 Co concentrations in the seawater and sediment media coupled with relatively constant 60 Co specific activities suggest a possible homeostatic control of cobalt concentrations in certain marine organisms. The evidence indicates that the marine animals derived more of the accumulated 60 Co from the sediments and interstitial water than from seawater. Cobalt-60 concentration factors were generally found to be lower than published cobalt concentration factors due to the predominantly insoluble nature of the corrosion products. Baseline information is provided on trace element concentrations in deep-sea organisms. Stable Co and twenty other elements were measured in abyssal invertebrates and a fish

  20. Microbiological Load Of Ethylene Oxide Sterilized Medical Devices And Its Elimination By Cobalt 60 Source

    International Nuclear Information System (INIS)

    Bashir, R.; Afroze, B.; Zulfiqar, H. F.; Saleem, R.; Saleem, F.; Aslam, F.; Naz, S.

    2016-01-01

    Objective: To determine the residing microbial flora of ethylene oxide (EtO) sterilized medical devices and optimization of safe dose of gamma radiation (Cobalt 60 source) for the complete elimination of microbial load. Study Design: Experimental study. Place and Duration of Study: Department of Biotechnology, Lahore College for Women University, Lahore, Pakistan from September 2014 to June 2015. Methodology: Thirty-six samples of EtO sterilized medical devices of same batch of three different companies were collected for this study. Isolation and enumeration of microbes were done by using different selective and differential media. Gram staining and biochemically characterization by API 20 (Bio Merieux, France) kit was done for identification of the microorganisms. The medical devices having high microbial load were sent to Pakistan Radiation Services (PARAS) for gamma irradiations at 3 different selected doses (20 KGy, 25 KGy, and 30 KGy). Result: Different types of Gram positive bacteria (Staphylococcus epidermidis, Staphylococcus aureus and Bacillus subtilis) were isolated from the EtO sterilized samples. Gram negative bacteria and fungi were not detected on these medical devices. Gamma irradiations Result showed that 30 KGy was optimized dose for complete elimination of microbial flora on endotracheal, Nelaton, and tracheostomy tubes. Conclusion: Gamma radiations (Co 60 source) effectively decontaminate the microbial flora on the equipment previously sterilized by the ethylene oxide gas; and 30 KGy is the optimized dose for all these medical devices. (author)

  1. Dose enhancement in a room cobalt-60 source

    International Nuclear Information System (INIS)

    Simons, M.; Pease, R.L.; Fleetwood, D.M.; Schwank, J.R.; Krzesniak, M.

    1997-01-01

    A room Co-60 source was characterized using TLDs and pMOS RADFETs. Dose enhancement was measured using RADFETs with and without gold- flashed kovar lids. A methodology was developed to predict dose enhancement vs position and test configuration

  2. Investigation of the production of cobalt-60 via particle accelerator

    Directory of Open Access Journals (Sweden)

    Artun Ozan

    2017-01-01

    Full Text Available The production process of cobalt-60 was simulated by a particle accelerator in the energy range of 5 to 100 MeV, particle beam current of 1 mA, and irradiation time of 1 hour to perform yield, activity of reaction, and integral yield for charged particle-induced reactions. Based on nuclear reaction processes, the obtained results in the production process of cobalt-60 were also discussed in detail to determine appropriate target material, optimum energy ranges, and suitable reactions.

  3. Effects of bathing on skin exposed to Cobalt-60 teletherapy

    International Nuclear Information System (INIS)

    Bohannan, P.A.

    1982-01-01

    The problem of this study was to determine the effects of bathing or not bathing on the degree of skin reaction occurring in patients receiving Cobalt-60 radiation therapy to the chest, back, or head and neck. A quasi experimental study was done using a 2 x 7 repeated measures design. Sixty-seven subjects receiving Cobalt-60 radiation therapy at the Moncrief Radiation Center in Fort Worth, Texas, were randomly assigned to an experimental group who did not bathe during therapy and a control group who did bathe with water during therapy. Observations were made after each 1000 rads of therapy and two weeks after the final treatment. Erythema and pigmentation measurements were taken using the Photovolt 670 and rates were assigned using the Baker-Leith Rating Scale. Findings from the study suggest that bathing the portal of entry with water during the treatment period does not influence the degree of skin response that occurs from Cobalt-60 teletherapy

  4. Calculation support for industrial production of cobalt-60 at Leningrad NPP

    International Nuclear Information System (INIS)

    Artemov, Vladimir; Elshin, Alexander; Ivanov, Alexander; Gorbunov, Evgeny; Ikonnikov, Roman; Pimenov, Alexander

    2008-01-01

    Cobalt-60 is industrially produced at the Leningrad NPP by irradiation of cobalt-59 in special-purpose facilities loaded into the RBMK reactor core (all 4 units). The paper describes calculation methods used to determine the current activity of cobalt in irradiation assemblies for their timely unloading. The described peculiarities of core calculation model account for continuous refueling, overloading of irradiation assemblies and individual thermohydraulics in each channel under variation of reactor power. Fuel burnup in the core is calculated with a time step of about 24 hours. The resulting values for cobalt activity and uncertainties are presented in the paper as well. Deviation of calculated cobalt activity from measured activity is within the experimental accuracy of 10% (at confidence probability of 0.95). (authors)

  5. Formation of amino acids by cobalt-60 irradiation of hydrogen cyanide solutions

    Science.gov (United States)

    Sweeney, M. A.; Toste, A. P.; Ponnamperuma, C.

    1976-01-01

    Experiments were conducted to study the pathway for the prebiotic origin of amino acids from hydrogen cyanide (HCN) under the action of ionizing radiation considered as an effective source of energy on the primitive earth. The irradiations were performed in a cobalt-60 source with a dose rate of 200,000 rad/hr. Seven naturally occurring amino acids are identified among the products formed by the hydrolysis of gamma-irradiated solutions of HCN: glycine, alanine, valine, serine, threonine, aspartic acid, and glutamic acid. The identity of these amino acids is established by gas chromatography and mass spectrometry. Control experiments provided evidence that the amino acids are not the result of contamination.

  6. R I 800. A new cobalt-60 sealed source design

    International Nuclear Information System (INIS)

    Freijo, Jose L.; Gomez, Gonzalo

    2006-01-01

    The consolidation of the international market of Co-60 sources and the perspective of its growth has encouraged the development of new types of sealed sources. The model R I 800 is designed for activities up to 65 kCi and allows a large spectrum of capsules with different specific activities. During three years Dioxitek developed the process of fabrication and qualifications to comply the design requirements and succeeded in the product approval. Today, the initial lot at an industrial scale of R I 800 sources is under fabrication and a first partial shipment of 100 kCi to the United Kingdom was successfully carried out at the end of October 2005. The whole lot is for export. Due to the versatility of the R I 800 sealed sources it was possible to use as raw material 1 MCi of Co-60 imported from Russia, irradiated in Leningrad nuclear power plant. (author) [es

  7. SU-F-T-530: Characterization of a 60-Leaf Motorized MLC Designed for Cobalt-60 Units

    International Nuclear Information System (INIS)

    Xu, L; Smith, L; Ciresianu, A

    2016-01-01

    Purpose: In a continuing effort to improve conformal radiation therapy with Cobalt-60 units, a 60-leaf MLC was designed, manufactured, and released to market. This work describes the physics measurements taken to characterize the clinical performance of this MLC. Methods: A 60 leaf MLC was custom designed with tungsten leaves of 4.5 cm height, single focused, achieving field size of 30×30 cm^2 when mounted on a 100cm SAD Cobalt-60 unit. Leakage and output factor measurements were performed using a single ion chamber in a solid water phantom. Penumbra and surface dose were measured using scanning chambers and diodes in a water phantom. Radiation-light coincidence measurements were performed using radiographic films. Results: With MLC mounted, measured penumbras at all depths are smaller than with jaws only. Surface doses were not significantly affected by the presence of MLC, and remained below values recommended by regulatory bodies. Light-radiation coincidences were found to be better than 3 mm for all field sizes. Leakage through the MLC was found to be strongly dependent on field size, increasing from 1.0 % for a 10×10 cm field to 2.0% for a 30×30 cm field. Such results meet the requirements of IEC 60601-2-11. The MLC was found to have significant influence on the output factor, when field size defined by MLC is significantly smaller than field size defined by jaws. Such effect is also observed on linear accelerators, but it is more pronounced on Cobalt-60 units. A 10×10 “diamond” MLC shape inside a 14×14 cm jaw showed output factor that is 5.7% higher than 10×10 cm field defined by matching MLC and jaws. Conclusion: The MLC offers clinically acceptable performance in penumbra, surface dose, and light-radiation coincidence. Several units of this MLC have recently been installed and used clinically. Validation of Cobalt-60 based IMRT with this MLC is ongoing. The authors are employees of Best Theratrnics Ltd.

  8. SU-F-T-530: Characterization of a 60-Leaf Motorized MLC Designed for Cobalt-60 Units

    Energy Technology Data Exchange (ETDEWEB)

    Xu, L; Smith, L; Ciresianu, A [Best Theratronics, Ottawa, ON (Canada)

    2016-06-15

    Purpose: In a continuing effort to improve conformal radiation therapy with Cobalt-60 units, a 60-leaf MLC was designed, manufactured, and released to market. This work describes the physics measurements taken to characterize the clinical performance of this MLC. Methods: A 60 leaf MLC was custom designed with tungsten leaves of 4.5 cm height, single focused, achieving field size of 30×30 cm^2 when mounted on a 100cm SAD Cobalt-60 unit. Leakage and output factor measurements were performed using a single ion chamber in a solid water phantom. Penumbra and surface dose were measured using scanning chambers and diodes in a water phantom. Radiation-light coincidence measurements were performed using radiographic films. Results: With MLC mounted, measured penumbras at all depths are smaller than with jaws only. Surface doses were not significantly affected by the presence of MLC, and remained below values recommended by regulatory bodies. Light-radiation coincidences were found to be better than 3 mm for all field sizes. Leakage through the MLC was found to be strongly dependent on field size, increasing from 1.0 % for a 10×10 cm field to 2.0% for a 30×30 cm field. Such results meet the requirements of IEC 60601-2-11. The MLC was found to have significant influence on the output factor, when field size defined by MLC is significantly smaller than field size defined by jaws. Such effect is also observed on linear accelerators, but it is more pronounced on Cobalt-60 units. A 10×10 “diamond” MLC shape inside a 14×14 cm jaw showed output factor that is 5.7% higher than 10×10 cm field defined by matching MLC and jaws. Conclusion: The MLC offers clinically acceptable performance in penumbra, surface dose, and light-radiation coincidence. Several units of this MLC have recently been installed and used clinically. Validation of Cobalt-60 based IMRT with this MLC is ongoing. The authors are employees of Best Theratrnics Ltd.

  9. Preliminary dosimetric methodology for a new cobalt-60 irradiator for radioinduced necrosis

    International Nuclear Information System (INIS)

    Moura, Eduardo S.; Mosca, Rodrigo C.; Zeituni, Carlos A.; Rostelato, Maria Elisa C.M.; Mathor, Monica B.; Sakuraba, Roberto K.; Goncalves, Vinicius D.

    2011-01-01

    The use of ionizing radiation in medical procedures, as radiotherapy, is a well-established clinical process and it has been used for several decades with good clinical results and continuous technology development for treatment optimization. On the contrary, some injuries such as necrosis, may occur with patients, due to wrong administration of the absorbed dose or with expected side effects. To evaluate how these injuries could be investigated and how they can be treated, a new Cobalto-60 irradiator was developed to induce radionecrosis in mice. This irradiator is composed by a cylindrical size and it was set up with eleven Cobalt-60 sources aligned in the surface of a cylindrical lead. This alignment guarantees a small dose focal area in a longitudinal table, with proper frames for positioning mice precisely during the irradiations period. The dosimetric procedure will measure the absorbed dose in the dose focal area, delimited the area of irradiation with penumbra regions (gradients absorbed dose profiles) and others anatomical regions of the mice with high radiosensitivity. Possible dosimetric procedures and related devices will be present in this work,. The obtained dosimetric data will be applied to ensure the accurate period of radiation of a given position. This preliminary study assures that the fundamental dosimetric process of this new Cobalt-60 irradiator and it predicates that dosimetric processes area feasible to be conducted. (author)

  10. Preliminary dosimetric methodology for a new cobalt-60 irradiator for radioinduced necrosis

    Energy Technology Data Exchange (ETDEWEB)

    Moura, Eduardo S.; Mosca, Rodrigo C.; Zeituni, Carlos A.; Rostelato, Maria Elisa C.M.; Mathor, Monica B., E-mail: esmoura@ipen.b [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil); Sakuraba, Roberto K.; Goncalves, Vinicius D. [Hospital Israelita Albert Einstein (HIAE), Sao Paulo, SP (Brazil)

    2011-07-01

    The use of ionizing radiation in medical procedures, as radiotherapy, is a well-established clinical process and it has been used for several decades with good clinical results and continuous technology development for treatment optimization. On the contrary, some injuries such as necrosis, may occur with patients, due to wrong administration of the absorbed dose or with expected side effects. To evaluate how these injuries could be investigated and how they can be treated, a new Cobalto-60 irradiator was developed to induce radionecrosis in mice. This irradiator is composed by a cylindrical size and it was set up with eleven Cobalt-60 sources aligned in the surface of a cylindrical lead. This alignment guarantees a small dose focal area in a longitudinal table, with proper frames for positioning mice precisely during the irradiations period. The dosimetric procedure will measure the absorbed dose in the dose focal area, delimited the area of irradiation with penumbra regions (gradients absorbed dose profiles) and others anatomical regions of the mice with high radiosensitivity. Possible dosimetric procedures and related devices will be present in this work,. The obtained dosimetric data will be applied to ensure the accurate period of radiation of a given position. This preliminary study assures that the fundamental dosimetric process of this new Cobalt-60 irradiator and it predicates that dosimetric processes area feasible to be conducted. (author)

  11. Cobalt-60 in the treatment of cancer-future scenario

    International Nuclear Information System (INIS)

    Sastri, K.V.S.; Patil, B.N.; Kohli, A.K.

    2009-01-01

    Treatment of cancer using radiation is established method. Cobalt-60 is the workhorse of cancer treatment from the beginning. Later linear accelerators with more accessories were developed and are now used for the advanced treatments like IMRT, IGRT etc. Gammaknife, Gyroknife and supergamma machines using 60 Co have also taken roots for the treatment of cancer. The use of 60 Co in the treatment of cancer is expected to continue for some more time to come. (author)

  12. Determination of cobalt-60 in seawater by solvent extraction with pyrrolidinedithiocarbamic acid

    International Nuclear Information System (INIS)

    Tseng, C.L.; Lo, J.M.

    1978-01-01

    Cobalt-60 was extracted from a large volume of seawater and concentrated in a small volume of organic solution of pyrrolidinedithiocarbamic acid (HPDC) in chloroform. All foreign nuclides in the organic phase were stripped completely with 12N HCl and 2N HNO 3 successively. By this procedure, a chemically pure Co-60 chelate, 60 Co(PDC) 3 , in chloroform was obtained. The recovery of Co-60 activity was found to average 99%. Cobalt-60 in seawater can thus be simply, rapidly and accurately determined by direct NaI(Tl) scintillation counting. The time for a single analysis, for example, exclusive of the counting operation, is about 40 min. The effects of various foreign nuclides on the extraction of Co-60 were examined by the use of 42 radiotracers and the results are tabulated. The nuclides Ag + , Mn 2+ , Ni 2+ , Cu 2+ , Zn 2+ , Cd 2+ , Pb 2+ , Hg 2+ , Fe 3+ , Ga 3+ , In 3+ , As 3+ , Sn 4+ , and Cr 6+ were extracted almost completely into chloroform with cobalt as the pyrrolidinedithiocarbamates. The extraction yield of Sb 3+ was close to 90%. Appreciable fractions of Cs + , Ba 2+ , Cr 3+ , Zr 4+ and Np 5+ were also found in the organic phase. (T.I.)

  13. Cobalt-60 production in the BN-350 fast power reactor

    International Nuclear Information System (INIS)

    Zvonarev, A.V.; Korobejnikov, V.V.; Matveenko, I.P.

    1994-01-01

    A possibility of Co-60 isotope production in the BN-350 fast reactor was considered. A special irradiating device, which is an assembly with a central hole, where a container containing cobalt and zirconium hydride is placed. The irradiating device tested permits generating 60 Co with specific activity of 100 Ci/g

  14. Measurement for cobalt target activity and its axial distribution

    International Nuclear Information System (INIS)

    Li Xingyuan; Chen Zigen.

    1985-01-01

    Cobalt target activity and its axial distribution are measured in process of producing radioactive isotopes 60 Co by irradiation in HFETR. Cobalt target activity is obtained with measured data at 3.60 m and 4.60 m, relative axial distribution of cobalt target activity is obtained with one at 30 cm, and axial distribution of cobalt target activity(or specific activity) is obtained with both of data. The difference between this specific activity and measured result for 60 Co teletherapy sources in the end is less than +- 5%

  15. Study of the point defects formed in cobalt by electron bombardment

    International Nuclear Information System (INIS)

    Sulpice, G.

    1968-12-01

    A study of the point defects formed in cobalt by electron bombardment is presented. The results are compared with those previously obtained for two other ferromagnetic metals of different structure, iron and nickel. In the first part we give a review of the literature concerning the creation of point defects, their contribution to resistivity and their annihilation mode in the three structure types. We then describe the experimental techniques adapted, in particular the study of the resistivity increase during a linear temperature rise. Our investigations concern the following, essential points : the observation of the successive annihilation stages of the point defects formed in pure cobalt, a study of the variations with respect to the doses and energy of the incident particles, and the determination of the annealing kinetics and the corresponding activation energies. The results are finally compared with the various models of point defect annihilation proposed for other metals: none of these interpretations is in perfect agreement with our results. In the case of cobalt we are thus led to modify the model proposed by our laboratory for iron an nickel. The difference between these three metals is explained by the anisotropic character of the cobalt matrix. (author) [fr

  16. Dosimetric intercomparison in Cobalt 60 unities using TLD-100 crystals and CaSO4: Dy + Ptfe

    International Nuclear Information System (INIS)

    Gaona, E.; Azorin N, J.; Perez P, M.A.; Castillo H, M.; Flores F, F.; Guzman R, L.V.

    1999-01-01

    The purpose of this work is to design and construct a phantom in basis of thermoplastic polymer of methyl methacrylate that is reutilizable and which allows to do an analysis of the absorbed doses in thermoluminescent crystals (Tl) exposed to cobalt 60 to establish the dosimetric intercomparison in cobalt units which allows to do the follow-up of the Quality assurance programs, standardization of calibration procedures, dosimetry and TLD post intercomparison in radiotherapy. This work allows also prove new thermoluminescent materials of national manufacture developed by Juan Azorin and collaborators as the CaSO 4 : Dy + Ptfe. This is a first study which is realized in Mexico with the system crystal-phantom for aims to intercomparison in cobalt 60 units. In this work participate eight unities of cobalt 60 of different trades belonging at four radiotherapy centers. The results of the dose intercomparison of the eight unities of cobalt 60 were in the range 0.95-1.13, taking in account that the values between 0.95 and 1.05 were considered acceptable in terms of the requirements by the standing legislation. (Author)

  17. Electronic equilibrium as a function of depth in tissue from cobalt-60 point source exposures

    International Nuclear Information System (INIS)

    Myrick, J.A.

    1994-08-01

    The Nuclear Regulatory Commission has set the basic criteria for assessing skin dose stemming from hot particle contaminations. Compliance with 10 CFR 20.101 requires that exposure to the skin be evaluated over a 1 cm 2 area at a depth of 0.007 cm. Skin exposure can arise from both the beta and gamma components of radioactive particles and gamma radiation can contribute significantly to skin doses. The gamma component of dose increases dramatically when layers of protective clothing are interposed between the hot particle source and the skin, and in cases where the hot particle is large in comparison to the range of beta particles. Once the protective clothing layer is thicker than the maximum range of the beta particles, skin dose is due solely to gamma radiation. Charged particle equilibrium is not established at shallow depths. The degree of electronic equilibrium establishment must be assessed for shallow doses to prevent the over-assessment of skin dose because conventional fluence-to-dose conversion factors are not applicable. To assess the effect of electronic equilibrium, selected thicknesses of tissue equivalent material were interposed between radiochromic dye film and a 60 Co hot particle source and dose was measured as a function of depth. These measured values were then compared to models which are used to calculate charged particle equilibrium. The Miller-Reece model was found to agree closely with the experimental data while the Lantz-Lambert model overestimated dose at shallow depths

  18. Cobalt-60 total body irradiation dosimetry at 220 cm source-axis distance

    International Nuclear Information System (INIS)

    Glasgow, G.P.; Mill, W.B.

    1980-01-01

    Adults with acute leukemia are treated with cyclophosphamide and total body irradiation (TBI) followed by autologous marrow transplants. For TBI, patients seated in a stand angled 45 0 above the floor are treated for about 2 hours at 220 cm source-axis distance (SAD) with sequential right and left lateral 87 cm x 87 cm fields to a 900 rad mid-pelvic dose at about 8 rad/min using a 5000 Ci cobalt unit. Maximum (lateral) to minimum (mid-plane) dose ratios are: hips--1.15, shoulders--1.30, and head--1.05, which is shielded by a compensator filter. Organ doses are small intestine, liver and kidneys--1100 rad, lung--1100 to 1200 rad, and heart--1300 rad. Verification dosimetry reveals the prescribed dose is delivered to within +-5%. Details of the dosimetry of this treatment are presented

  19. Cobalt-60 simulation of LOCA [loss of coolant accident] radiation effects

    International Nuclear Information System (INIS)

    Buckalew, W.H.

    1989-07-01

    The consequences of simulating nuclear reactor loss of coolant accident (LOCA) radiation effects with Cobalt-60 gamma ray irradiators have been investigated. Based on radiation induced damage in polymer base materials, it was demonstrated that electron/photon induced radiation damage could be related on the basis of average absorbed radiation dose. This result was used to estimate the relative effectiveness of the mixed beta/gamma LOCA and Cobalt-60 radiation environments to damage both bare and jacketed polymer base electrical insulation materials. From the results obtained, it is concluded that present simulation techniques are a conservative method for simulating LOCA radiation effects and that the practices have probably substantially overstressed both bare and jacketed materials during qualification testing. 9 refs., 8 figs., 5 tabs

  20. Quality assurance and accuracy in Co-60 radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Scarlat, F; Rebigan, F

    1995-12-01

    The characteristics of a set of 88 Co-60 sources ONCOBALT, are described. This set of radioactive sources is an original choice of a variety of cobalt sources in point of physical size and activity. It includes 5 activity groups of cells (stainless steel) among 2 and 12 mCi, 5 and 15 mm active length and 2, 2.5 and 3 mm external diameter, 4 activity groups of needle activities between 1.3 and 3.4 mCi, 15 and 20 mm active length, 1.8 mm external diameter. By an appropriate choice of activities, dimensions and geometry of irradiation we can get an error of max.5% as to the receive dose. The radioactive purity of cobalt is 99.9%. To meet the requirements in practical radiotherapy we checked the Co-60 sources by tests: tight test, mechanical test, corrosion test and contamination test that gave us full satisfaction.

  1. Sedimentation of cobalt-60 and caesium-137 released in Tvaeren, a Baltic bay

    International Nuclear Information System (INIS)

    Ramberg, L.

    1984-01-01

    The amounts of cobalt-60 and caesium-137 bound in the sediment in a bay off the Studsvik research station were determined. Of the cumulative released activity during 22 years, 19% of 60 Co and 1.8% of 137 Cs were found in the sediments within an area of 23 km 2 . The rate of input through sedimentation and the loss rate through physical decay were of the same order in 1981 and were close to steady state for 60 Co while for 137 Cs they had only reached 30% of that level. The sedimentation coefficients calculated for the bay were 6.5 year -1 for 60 Co and 0.49 year -1 for 137 Cs, higher values than many published previously. Cobalt-60 seemed to precipitate close to the outlet and to migrate near the bottom as bed-load. (author)

  2. Model for cobalt 60/58 deposition on primary coolant piping in a boiling water reactor

    International Nuclear Information System (INIS)

    Dehollander, W.R.

    1979-01-01

    A first principles model for deposition of radioactive metals into the corrosion films of primary coolant piping is proposed. It is shown that the predominant mechanism is the inclusion of the radioactive species such as Cobalt 60 into the spinel structure of the corrosion film during the act of active corrosion. This deposition can occupy only a defined fraction of the available plus 2 valence sites of the spinel. For cobalt ions, this ratio is roughly 4.6 x 10 -3 of the total iron sites. Since no distinction is made between Cobalt 60, Cobalt 58, and Cobalt 59 in this process, the radioactivity associated with this inclusion is a function of the ratio of the radioactive species to the nonradioactive species in the water causing the corrosion of the pipe metal. The other controlling parameter is the corrosion rate of the pipe material. This can be a function of time, for example, and it shown that freshly descaled metal when exposed to the cobalt containing water can incorporate as much as 10 x 10 -3 cobalt ions per iron atom in the initial corrosion period. This has implications for the problem of decontaminating nuclear reactor piping. Equations and selected observations are presented without reference to any specifically identified reactor or utility, so as to protect any proprietary interest

  3. Determination of C0-60 in Cobalt Slugs and Slabs and Radionuclides in Curium Sampler Slugs L-Reactor Disassembly Basin

    International Nuclear Information System (INIS)

    Casella, V.R.

    2004-01-01

    Co-60 was historically produced in the SRS reactors. Cobalt slugs were irradiated in the early 1970s. Post-production, remaining cobalt slugs (including slab form) were consolidated for storage. There are approximately nine hundred cobalt slugs currently stored awaiting final disposition. These slugs had historically incomplete documentation for activity rates; therefore, assaying was required in order to determine their activity levels. Since the gamma dose rate from these slugs is extremely high, the most cost effective way to shield a source of this magnitude from personnel and the radiation detector was to use the basin water in which the slugs are stored as the shield. A sodium iodide gamma detector was placed above a specially designed air collimator assembly, so that slug was at least eight feet from the detector and was shielded by the basin water. Using a sodium iodide detector and multichannel analyzer system and an underwater collimator assembly, Co-60 concentrations we re determined for Disassembly Basin cobalt slugs and slabs and 18 curium sampler slugs. The total activity of all of the assayed slugs summed to 31,783 curies. From the Co-60 concentrations of the curium sampler slugs, the irradiation flux was determined for the known irradiation time. The amounts of Pu-238, 239, 240, 241, 242; Am-241, 243; and Cm-242, 244 produced were then obtained based on the original amount of Pu-239 irradiated

  4. Recent status on cobalt-60 gamma ray radiation sources production and its application in China

    International Nuclear Information System (INIS)

    Cao Zhijian; Song Yunjiang; Zhang Chunhua; Li Maoling

    1993-01-01

    This paper describes the status of Co-60 γ ray radiation sources and their application in China. At present, the production capacity of Co-60 γ ray radiation sources in China is about 11.1 PBq (0.3 MCi) per year. 5 years later, it is increased to 37 PBq (1 MCi) per year. The radioactivity of each source is 370 TBq - 740 TBq (1000-2000 Ci). There are over 150 Co-60 γ ray radiation facilities with total design capacity of over 370 PBq (10 MCi) and practical capacity of about 92.5 PBq (2.5 MCi) in operation. The number of Co-60 γ ray radiation facilities with practical capacity of over 3.7 PBq (0.1 MCi) is 14. The main applications of the Co-60 γ ray sources are radiation crosslinking, radiation sterilization of disposable medical supplies and food irradiation. The prospects for Co-60 γ ray radiation source application in China are good. (author)

  5. sup(60)Co hot atom chemistry of tris(acetylacetonato) cobalt(III) adsorbed on silica gel

    International Nuclear Information System (INIS)

    Nishioji, H.; Sakai, Y.; Tominaga, T.

    1985-01-01

    The sup(60)Co hot atom reactions were studied in tris(acetylacetonato)cobalt(III) adsorbed on silica gel surface. sup(57)Fe Moessbauer spectra of tris(acetylacetonato)iron(III) in the corresponding system were also measured in order to examine the state of dispersion of complex molecules on silica gel. The retention formation processes were discussed in terms of the dependence of sup(60)Co retention on the adsorbed amount (concentration) of cobalt(III) complexes. (author)

  6. New formula for calculation of cobalt-60 percent depth dose

    International Nuclear Information System (INIS)

    Tahmasebi Birgani, M. J.; Ghorbani, M.

    2005-01-01

    On the basis of percent depth dose calculation, the application of - dosimetry in radiotherapy has an important role to play in reducing the chance of tumor recurrence. The aim of this study is to introduce a new formula for calculating the central axis percent depth doses of Cobalt-60 beam. Materials and Methods: In the present study, based on the British Journal of Radiology table, nine new formulas are developed and evaluated for depths of 0.5 - 30 cm and fields of (4*4) - (45*45) cm 2 . To evaluate the agreement between the formulas and the table, the average of the absolute differences between the values was used and the formula with the least average was selected as the best fitted formula. The Microsoft Excel 2000 and the Data fit 8.0 soft wares were used to perform the calculations. Results: The results of this study indicated that one amongst the nine formulas gave a better agreement with the percent depth doses listed in the table of British Journal of Radiology . The new formula has two parts in terms of log (A/P). The first part as a linear function with the depth in the range of 0.5 to 5 cm and the other one as a second order polynomial with the depth in the range of 6 to 30 cm. The average of - the differences between the tabulated and the calculated data using the formula (Δ) is equal to 0.3 152. Discussion and Conclusion: Therefore, the calculated percent depth dose data based on this formula has a better agreement with the published data for Cobalt-60 source. This formula could be used to calculate the percent depth dose for the depths and the field sizes not listed in the British Journal of Radiology table

  7. Cobalt-60 oxide aerosols: methods of production and short-term retention and distribution kinetics in the beagle dog

    International Nuclear Information System (INIS)

    Barnes, J.E.; Kanapilly, G.M.; Newton, G.J.

    1976-01-01

    Cobalt-60 has been used extensively in nuclear applications and has been considered for use in nuclear auxiliary power devices. The most common chemical form used is the oxide. This study of the retention and distribution of two differnt exoides of cobalt when administered by inhalation was conducted to assess the potential inhalation hazard associated with its use. Cobaltosic oxide (Co 3 O 4 ) was formed by passing a cobalt nitrate aerosol through a heating column at 850 0 C before delivery to the dog. Cobaltous oxide (CoO) was formed by raising the heating column temperature to 1400 0 C. Three beagle dogs were exposed to 60 Co 3 O 4 and sacrificed singly at 8, 64 and 128 days. Three beagle dogs were exposed to 60 CoO and sacrificed at 8, 16 and 64 days after exposure. Whole-body retention patterns showed that 60 CoO left the body with a shorter effective half-life than 60 Co 3 O 4 . The concentration of 60 Co detected in the blood was at least an order of magnitude higher in the dogs exposed to 60 CoO than in the dogs exposed to 60 Co 3 O 4 . Cobalt-60 translocated from the lung accumulated predominantly in the kidney, liver, skeleton and cartilagenous structures such as the trachea. Higher concentrations were reached earlier in the dogs exposed to 60 CoO. After early fecal excretion of material deposited in the upper respiratory tract, excretion was greatest via the urine. The higher solubility of the 60 CoO formed at 1400 0 C relative to 60 Co 3 O 4 formed at 850 0 C is noteworthy considering that generally aerosols formed at higher temperatures are more insoluble than aerosols formed at lower temperatures. (author)

  8. Study of the point defects formed in cobalt by electron bombardment; Etude des defauts ponctuels crees par bombardement electronique dans le cobalt

    Energy Technology Data Exchange (ETDEWEB)

    Sulpice, G [Commissariat a l' Energie Atomique, 38 - Grenoble (France). Centre d' Etudes Nucleaires

    1968-12-01

    A study of the point defects formed in cobalt by electron bombardment is presented. The results are compared with those previously obtained for two other ferromagnetic metals of different structure, iron and nickel. In the first part we give a review of the literature concerning the creation of point defects, their contribution to resistivity and their annihilation mode in the three structure types. We then describe the experimental techniques adapted, in particular the study of the resistivity increase during a linear temperature rise. Our investigations concern the following, essential points : the observation of the successive annihilation stages of the point defects formed in pure cobalt, a study of the variations with respect to the doses and energy of the incident particles, and the determination of the annealing kinetics and the corresponding activation energies. The results are finally compared with the various models of point defect annihilation proposed for other metals: none of these interpretations is in perfect agreement with our results. In the case of cobalt we are thus led to modify the model proposed by our laboratory for iron an nickel. The difference between these three metals is explained by the anisotropic character of the cobalt matrix. (author) [French] Nous presentons une etude des defauts ponctuels crees par bombardement electronique dans le cobalt et comparons nos resultats a ceux obtenus precedemment dans deux autres metaux ferromagnetiques de structure differente, le fer et le nickel. Dans une premiere partie nous faisons une mise au point bibliographique comparee sur la creation des defauts, leur contribution a la resistivite et leur mode d'annihilation dans les trois types de structure. Nous decrivons ensuite les techniques experimentales mises au point, en particulier l'etude du revenu de la resistivite au cours d'une montee lineaire de temperature. Au cours de ce travail, nous avons mis en evidence les stades successifs d

  9. Effect of cobalt sources on properties of co-b catalysts synthesized by sol-gel method

    Energy Technology Data Exchange (ETDEWEB)

    Figen, Aysel Kantürk; Co ú kuner, Bilge; Özdemir, Özgül Dere [Department of Chemical Engineering, Yildiz Technical University Istanbul (Turkey); Burçin Pi ú kin, Mehmet [Department of Bioengineering, Y Õ ld Õ z Technical University, Istanbul (Turkey)

    2013-07-01

    In this studying, Co-B catalysts were prepared by sol-gel method via kinds of cobalt source for clarifying the effect of these for characteristic properties of Co-B catalysts. Co sources, cobalt(II)chloride (CoCl{sub 2} .6H{sub 2}O), cobalt(II)sulfate (CoSO{sub 4} .7H{sub 2}O) and cobalt(II)nitrate (Co(NO{sub 3}){sub 2} .6H{sub 2}O), were used as a metal source with boron oxide (B{sub 2}O{sub 3} ) while citric acid (C{sub 6}H{sub 8}O{sub 7} ) used as organic ligand to forming sol-gel structure. The crystalline structures of Co-B catalysts were determined by X-ray diffraction. The N{sub 2} sorption technique was used for analyzing catalysts surface area. The variety of Co-B catalysts morphological properties were investigated via scanning electron microscope. By the effect of cobalt sources the Co-B catalyst’s properties were altered that clarified from analysis results. The amorphous Co-B catalyst produced from CoCl{sub 2}.6H{sub 2} O as metal source had the largest porous surface area with 122.7 m 2 .g -1 . Investigation of hydrolysis were performed under variety of temperatures (22, 40 and 60 o C), NaOH concentrations (1-15 wt. %) and NaBH 4 /Co-B catalyst ratio (2-40 wt./wt.) ratios in order to investigate the activation of Co-B catalyst. The maximum hydrogen generation rate 0.84L H 2 .min -1 .g -1 was obtained under 40 °C, 10 wt. % NaOH and 9.52wt./wt. NaBH{sub 4}/Co-B catalyst ratio. Yet the kinetic investigations, the reaction order was found that zero order with 0.9954 coefficient of correlation and 51.83 kJ/mol activation energy. Key words: Sol-gel, Co-B Catalyst, Boron.

  10. Introduction dosimetric data of cobalt-60 unit in planning new Win-PTL- 3D

    International Nuclear Information System (INIS)

    Gonzalez Perez, Yelina; Rodriguez Zayas, Michael; Perez Guevara, Adrian; Sanchez Zamora, Luis; Reyes Gonzalez, Tommy; Sola Rodriguez, Yeline; Caballero, Roberto; Cruz Marcane, Viviana

    2009-01-01

    3D planning is based on the individual and image reconstruction formation of fields, allowing better absorption of dose volume White minimizing damage to surrounding healthy tissue. During the clinical implementation of the Win-PLT software includes validation from the implementation of dosimetric acceptance tests through a series of precise experimental measurements, reflecting different clinical situations (test cases). For the commissioning characterized the photon beam Cobalt Unit 60, taking measurements with a set consisting of a phantom dosimetric automatic ionization chambers and electrometer Tandem. The measured data are used to power the TPS through WINCOM auxiliary program that lets you adjust a number of parameters to model the photon beam. This adjustment is made by comparing the PDD curves and profiles of experimental data with modeled data. The test cases performed are in compliance with the requirements proposed in the geometric of the AAPM TG55. The modeling of beam dosimetry data was successful, since the discrepancies were within the criteria TRS-430. The cases involved events where points near the edge of the field and in the presence of blocking a discrepancy outside the tolerance, suggesting not to use these items for purposes of limitation. Win TPS-PLT is suitable for clinical use with the photon beam Cobalt Unit 60, backed by the reliability that dropped on the results of beam modeling and verification of dosimetric calculations. (Author)

  11. Forward-planned intensity modulated radiation therapy using a cobalt source: A dosimetric study in breast cancer

    Directory of Open Access Journals (Sweden)

    Savino Cilla

    2013-01-01

    Full Text Available This analysis evaluates the feasibility and dosimetric results of a simplified intensity-modulated radiotherapy (IMRT treatment using a cobalt-therapy unit for post-operative breast cancer. Fourteen patients were included. Three plans per patient were produced by a cobalt-60 source: A standard plan with two wedged tangential beams, a standard tangential plan optimized without the use of wedges and a plan based on the forward-planned "field-in-field" IMRT technique (Co-FinF where the dose on each of the two tangential beams was split into two different segments and the two segments weight was determined with an iterative process. For comparison purposes, a 6-MV photon standard wedged tangential treatment plan was generated. D mean , D 98% , D 2% , V 95% , V 107%, homogeneity, and conformity indices were chosen as parameters for comparison. Co-FinF technique improved the planning target volume dose homogeneity compared to other cobalt-based techniques and reduced maximum doses (D 2% and high-dose volume (V 110% . Moreover, it showed a better lung and heart dose sparing with respect to the standard approach. The higher dose homogeneity may encourage the adoption of accelerated-hypofractionated treatments also with the cobalt sources. This approach can promote the spread of breast conservative treatment in developing countries.

  12. Absolute exposure determination of cobalt-60 gamma radiation

    International Nuclear Information System (INIS)

    Ahmad, S.S.; Ali, A.; Orfi, S.D.

    1986-02-01

    The report describes the procedure for the determination of absolute exposure for Cobalt-60 gamma radiation. A graphite cavity chamber, nominal volume of 1 cm 3 , manufactured by Austrian Research Centre Seibersdorf has been used. The exposure rate at reference distance determined with the graphite chamber was compared with mean exposure rate measured with NPL-Therapy level X-ray exposure meter normalized to same date. An agreement of 0.39% was found between the two measuring systems, which seems to be very encouraging and quite satisfactory. (authors)

  13. Comparison of three methods for the calibration of cobalt-60 teletherapy machine

    International Nuclear Information System (INIS)

    Adewole, O.O.; Akinlade, B.I.; Oyekunle, O.E.; Ejeh, J.

    2011-01-01

    Two methods of indirect determination of dose rate (machine output) from the Cobalt-60 Teletherapy machines has been reviewed and compared with conventional measurement with dosimetry devices. The dose rate were determined by: (i) Conventional measurement (ii) Application of the law of radioactive decay and (iii) Assumption of 1 % radioactive decomposition per month. The dose rate at the depth of maximum dose (Z m ax), collimator size of 10cm x 10cm and Source to Skin Distance (SSD) of 80cm obtained from these methods were 203.7200cGy/min, 203.8090cGy/min and 203.9530cGy/min respectively. The ratio of dose rate obtained from measurement to that from calculations is within the tolerance value of 2%.

  14. Process of contamination of two trophic dulcaquicole chains by cobalt 60. I

    International Nuclear Information System (INIS)

    Amiard-Triquet, C.; Foulquier, L.

    1978-01-01

    In order to evaluate Cobalt 60 behavior in freshwater ecosystems, two food chains including different nutritionally interdependent species in a natural environment were defined. This article covers the dynamics of water-borne contamination in the species. (Auth.)

  15. Effect of different ionizing radiation doses and dose rates, using Cobalt-60 and electrons beam sources, on the staphylococcal enterotoxin inoculated in mechanically deboned chicken meat

    International Nuclear Information System (INIS)

    Pomarico Neto, Walter; Brito, Poliana de Paula; Azevedo, Heliana de; Roque, Claudio Vitor; Fukuma, Henrique Takuji; Kodama, Yasko; Miya, Norma Terugo Nago; Pereira, Jose Luiz

    2011-01-01

    The purpose of food irradiation is the destruction of present pathogenic microorganisms and the increase of shelf life of foods. To achieve this process, the source of cobalt-60 and the electron accelerator can be used. The mechanically deboned chicken meat (MDCM) is used for the production of traditional meat products, and it may come to present pathogenic microorganisms such as staphylococcus aureus, a bacterium that produces enterotoxin, which causes food poisoning. The objective of this study is to analyze the effect of ionizing irradiation with different doses and dose rates, deriving from different radiation sources, on staphylococcal enterotoxin type B (SEB) in the MDCM. 50 g samples of MDCM were prepared in a batch of 6 kg of MDCM. The samples were contaminated, with the exception of the control, with SEB in amounts of about 100 ng. Then they were conditioned in a transparent bag made of low density polyethylene, frozen at -18±1 deg C overnight and irradiated in these conditions with doses of 0.0 kGy (control), 1.5 kGy and 3.0 kGy, and with three different dose rates, both in the Cobalt-60 and the electron accelerator. The experiments were conducted in quintuplicate. The SEB extraction from the MDCM was performed according to the protocol recommended by the manufacturer of the kit VIDAS Staph Enterotoxin II (bioMerrieux). The principle of mass balance was used to determine the actual amount of SEB removed by irradiation. The treatment that presented the best results was the one with a dose of 1.5 kGy, high dose rate of the electron accelerator. (author)

  16. Effect of different ionizing radiation doses and dose rates, using Cobalt-60 and electrons beam sources, on the staphylococcal enterotoxin inoculated in mechanically deboned chicken meat

    Energy Technology Data Exchange (ETDEWEB)

    Pomarico Neto, Walter; Brito, Poliana de Paula; Azevedo, Heliana de; Roque, Claudio Vitor; Fukuma, Henrique Takuji, E-mail: pbrito@cnen.gov.br, E-mail: hazevedo@cnen.gov.br, E-mail: cvroque@cnen.gov.br, E-mail: htfukuma@cnen.gov.br [Brazilian Nuclear Energy Commission (LAPOC/CNEN), Pocos de Caldas, MG (Brazil); Kodama, Yasko, E-mail: ykodama@ipen.br [Nuclear and Energy Research Institute (IPEN/CNEN-SP), Sao Paulo, SP (Brazil); Miya, Norma Terugo Nago; Pereira, Jose Luiz, E-mail: miya@fea.unicamp.br, E-mail: pereira@fea.unicamp.br [Campinas State University (UNICAMP), SP (Brazil). Dept. of Food Sciences

    2011-07-01

    The purpose of food irradiation is the destruction of present pathogenic microorganisms and the increase of shelf life of foods. To achieve this process, the source of cobalt-60 and the electron accelerator can be used. The mechanically deboned chicken meat (MDCM) is used for the production of traditional meat products, and it may come to present pathogenic microorganisms such as staphylococcus aureus, a bacterium that produces enterotoxin, which causes food poisoning. The objective of this study is to analyze the effect of ionizing irradiation with different doses and dose rates, deriving from different radiation sources, on staphylococcal enterotoxin type B (SEB) in the MDCM. 50 g samples of MDCM were prepared in a batch of 6 kg of MDCM. The samples were contaminated, with the exception of the control, with SEB in amounts of about 100 ng. Then they were conditioned in a transparent bag made of low density polyethylene, frozen at -18{+-}1 deg C overnight and irradiated in these conditions with doses of 0.0 kGy (control), 1.5 kGy and 3.0 kGy, and with three different dose rates, both in the Cobalt-60 and the electron accelerator. The experiments were conducted in quintuplicate. The SEB extraction from the MDCM was performed according to the protocol recommended by the manufacturer of the kit VIDAS Staph Enterotoxin II (bioMerrieux). The principle of mass balance was used to determine the actual amount of SEB removed by irradiation. The treatment that presented the best results was the one with a dose of 1.5 kGy, high dose rate of the electron accelerator. (author)

  17. Quality and security on the uses of cobalt 60 sources for industrial irradiators

    International Nuclear Information System (INIS)

    Desroches, J.

    1976-01-01

    The construction and operation of industrial irradiators using large quantities of 60 Co give rise to an important problem of security. The CEA Radioisotope Department which manufactures and sells sources of 60 Co has created an insurance Quality System which insures the maximum of security for the user

  18. Characteristics and locations of sources

    International Nuclear Information System (INIS)

    Lahtinen, J.; Poellaenen, R.; Toivonen, H.

    1997-01-01

    Ten artificial radiation sources were placed in the terrain in order to test the capability of airborne measuring teams to detect them. One of the sources was a line source, others were point sources (three of them collimated). The radionuclides used in the sources were 60 Co, 137 Cs, 99m Tc and 192 Ir. The source activities ranged from about 26 MBq (one of the cobalt sources) to 0.56 TBq (iridium). (au)

  19. The ''Cobalt 60 Case'' in Taiwan. Conclusions; Das Kobalt-60 Ereignis von Taiwan. Und was ist daraus zu schliessen?

    Energy Technology Data Exchange (ETDEWEB)

    Niemann, Lutz

    2017-08-15

    The ''Cobalt 60 Case'' in Taiwan gives an opportunity for check of the thesis of radiation hormesis. Apartment residents have been exposed to cobalt-60 contaminated steel buildings. The results of a study strongly suggest that whole-body chronic irradiation, in the dose rate range that the apartment residents received, caused no symptomatic adverse health effects, such as radiation sickness, or the increased cancer or increased congenital disease that are predicted by ICRP theories. On the contrary, those who were exposed had lower incidences of cancer mortality and congenital malformations.

  20. Quality and security on the uses of cobalt 60 sources for industrial irradiators

    International Nuclear Information System (INIS)

    Desroches, J.

    1976-01-01

    The construction and operation of industrial irradiators using large quantities of 60 Co give rise to an important problem of security. The CEA Radioisotope Department which manufactures and sells sources of 60 Co has created an insurance quality system which insures the maximum of security for the user. (orig.) [de

  1. Safety analysis report: packages cobalt-60 shipping cask (packaging of radioactive and fissile materials)

    International Nuclear Information System (INIS)

    Evans, J.E.; Langhaar, J.W.

    1973-07-01

    Safety Analysis Report DPSPU-73-124-1 replaces DPSPU-69-124-1 and Supplement 1 to permit shipment of 350,000 curies of 60 Co (maximum) in cobalt-60 shipping casks in compliance with 10 CFR Part 71, Packaging of Radioactive Materials for Transport

  2. Semi-empirical equivalent field method for dose determination in midline block fields for cobalt - 60 beam

    International Nuclear Information System (INIS)

    Tagoe, S.N.A.; Nani, E.K.; Yarney, J.; Edusa, C.; Quayson-Sackey, K.; Nyamadi, K.M.; Sasu, E.

    2012-01-01

    For teletherapy treatment time calculations, midline block fields are resolved into two fields, but neglecting scattering from other fields, the effective equivalent square field size of the midline block is assumed to the resultant field. Such approach is underestimation, and may be detrimental in achieving the recommended uncertainty of ± 5 % for patient's radiation dose delivery. By comparison, the deviations of effective equivalent square field sizes by calculations and experiments were within 13.2 % for cobalt 60 beams of GWGP80 cobalt 60 teletherapy. Therefore, a modified method incorporating the scatter contributions was adopted to estimate the effective equivalent square field size for midline block field. The measured outputs of radiation beams with the block were compared with outputs of square fields without the blocks (only the block tray) at depths of 5 and 10 cm for the teletherapy machine employing isocentric technique, and the accuracy was within ± 3 % for the cobalt 60 beams. (au)

  3. Effect of cobalt-60 radiation on response to endodontic therapy in monkeys

    International Nuclear Information System (INIS)

    Matson, J.E.; Patterson, S.S.; Kafrawy, A.H.; Hornback, N.B.; Shidnia, H.

    1978-01-01

    Response of teeth that had received therapeutic doses of Cobalt-60 radiation to endodontic therapy were investigated in three monkeys. The results indicated no appreciable effect of the irradiation on the response to root canal treatment aside from reduction in osteoblastic activity

  4. Cobalt-60 gamma irradiation of shrimp

    International Nuclear Information System (INIS)

    Sullivan, N.L.B.

    1993-01-01

    Meta- and ortho-tyrosine were measured using high performance liquid chromatography (HPLC) in conjunction with electrochemical detection in shrimp irradiated using cobalt-60 gamma radiation in the absorbed dose range 0.8 to 6.0 kGy, in nonirradiated shrimp, and in bovine serum albumin (BSA) irradiated in dilute aqueous solution at 25.0 kGy. Ortho-tyrosine was measured in nonirradiated BSA. Para-, meta-, and ortho-tyrosine was measured using HPLC in conjunction with uv-absorption detection in dilute aqueous solutions of phenylalanine irradiated in the absorbed dose range 16.0 to 195.0 kGy. The measured yields of tyrosine isomers were approximately linear as a function of absorbed dose in shrimp, and in irradiated solutions of phenylalanine up to 37.0 kGy. The occurrence of meta- and ortho-tyrosine, which had formerly been considered unique radiolytic products, has not previously been reported in nonirradiated shrimp or BSA. The conventional hydrolyzation and analytical techniques used in the present study to measure meta- and ortho-tyrosine may provide the basis for a method to detect and determine the dose used in food irradiation

  5. Consumer products polluted by cobalt-60 on the Dutch market

    International Nuclear Information System (INIS)

    Bothof, J.

    2002-01-01

    In several previous articles of this magazine attention has been paid to reporting of radioactive materials in scrap metals and incidents with radioactive materials, which were dealt with by the VROM-Inspectie Regio Zuid-West (Inspection for the Region South-West in the Netherlands). In this article attention is paid to a special incident with new stainless steel flanges, polluted by cobalt 60 [nl

  6. Effect of antioxidants on thiobarbituric acid reactive substances, psychrotrophic bacteria and functional properties of mechanically deboned chicken meat irradiated with Cobalto-60 and electron beam sources

    Energy Technology Data Exchange (ETDEWEB)

    Brito, Poliana de Paula; Azevedo, Heliana de; Roque, Claudio Vitor; Pomarico Neto, Walter, E-mail: hgomes@cnen.gov.br, E-mail: pbrito@cnen.gov.br, E-mail: cvroque@cnen.gov.br, E-mail: abrusqui@cnen.gov.br [Comissao Nacional de Energia Nuclear (LAPOC/CNEN-MG), Pocos de Caldas, MG (Brazil). Laboratorio de Pocos de Caldas; Mourao, Gerson Barreto; Orlando, Eduardo Adilson; Miyagusku, Luciana, E-mail: marciamh@ital.sp.gov.br, E-mail: eduardo.orlando@ital.sp.gov.br [Instituto de Tecnologia dos Alimentos (ITAL), Campinas, SP (Brazil)

    2013-07-01

    Samples of MDCM with skin were divided into three groups: control (without antioxidants), Antioxidant 1 (Sodium Polyphosphate and Sodium Ascorbate and Antioxidant 2 (Rosemary Extract and α-Tocopherol. The three batches of samples were divided into nine groups: no antioxidant and non-irradiated (C), with antioxidant A1 and non-irradiated (A1), with antioxidant A2 and non-irradiated (A2) without antioxidant and irradiated in Cobalt-60 source (Co), with antioxidant A1 irradiated in Cobalt 60 source (A1Co) with antioxidant A2 irradiated in Cobalt-60 source (A2Co) with antioxidant A1 irradiated in Electron beam (A1Eb) and with antioxidant A2 irradiated in Electron beam (A2Eb). The samples was conditioned in a transparent, low density frozen overnight at a temperature of -18 ± 1 deg C in a chamber, and irradiated in this state with a dose of 3.0 kGy, used two sources of radiation: Cobalt-60 (3.1 kGy/h) and electron beam (7.86 kGy/s). After this process, the samples were evaluated during the refrigeration period (2 ± 1 deg C) for 11 days for the following analysis: total psychrotrophic bacteria count and thiobarbituric acid reactive substances (TBARS) and the analysis of functional properties were performed after the irradiation process. The use of the combination of rosemary antioxidant and α-tocopherol were able to significantly decrease TBARS values caused by the irradiation of samples in MDCM cobalt-60 sources and electron beam, and show a synergetic effect to processing with ionizing radiation to reduce of psychrotrophic bacteria count. The use of irradiation processing of MDCM did not negatively affect the functional properties studied. (author)

  7. Effect of antioxidants on thiobarbituric acid reactive substances, psychrotrophic bacteria and functional properties of mechanically deboned chicken meat irradiated with Cobalto-60 and electron beam sources

    International Nuclear Information System (INIS)

    Brito, Poliana de Paula; Azevedo, Heliana de; Roque, Claudio Vitor; Pomarico Neto, Walter

    2013-01-01

    Samples of MDCM with skin were divided into three groups: control (without antioxidants), Antioxidant 1 (Sodium Polyphosphate and Sodium Ascorbate and Antioxidant 2 (Rosemary Extract and α-Tocopherol. The three batches of samples were divided into nine groups: no antioxidant and non-irradiated (C), with antioxidant A1 and non-irradiated (A1), with antioxidant A2 and non-irradiated (A2) without antioxidant and irradiated in Cobalt-60 source (Co), with antioxidant A1 irradiated in Cobalt 60 source (A1Co) with antioxidant A2 irradiated in Cobalt-60 source (A2Co) with antioxidant A1 irradiated in Electron beam (A1Eb) and with antioxidant A2 irradiated in Electron beam (A2Eb). The samples was conditioned in a transparent, low density frozen overnight at a temperature of -18 ± 1 deg C in a chamber, and irradiated in this state with a dose of 3.0 kGy, used two sources of radiation: Cobalt-60 (3.1 kGy/h) and electron beam (7.86 kGy/s). After this process, the samples were evaluated during the refrigeration period (2 ± 1 deg C) for 11 days for the following analysis: total psychrotrophic bacteria count and thiobarbituric acid reactive substances (TBARS) and the analysis of functional properties were performed after the irradiation process. The use of the combination of rosemary antioxidant and α-tocopherol were able to significantly decrease TBARS values caused by the irradiation of samples in MDCM cobalt-60 sources and electron beam, and show a synergetic effect to processing with ionizing radiation to reduce of psychrotrophic bacteria count. The use of irradiation processing of MDCM did not negatively affect the functional properties studied. (author)

  8. The role of Cobalt-60 source in Intensity Modulated Radiation Therapy: From modeling finite sources to treatment planning and conformal dose delivery

    Science.gov (United States)

    Dhanesar, Sandeep Kaur

    Cobalt-60 (Co-60) units played an integral role in radiation therapy from the mid-1950s to the 1970s. Although they continue to be used to treat cancer in some parts of the world, their role has been significantly reduced due to the invention of medical linear accelerators. A number of groups have indicated a strong potential for Co-60 units in modern radiation therapy. The Medical Physics group at the Cancer Center of the Southeastern Ontario and Queen's University has shown the feasibility of Intensity Modulated Radiation Therapy (IMRT) via simple conformal treatment planning and dose delivery using a Co-60 unit. In this thesis, initial Co-60 tomotherapy planning investigations on simple uniform phantoms are extended to actual clinical cases based on patient CT data. The planning is based on radiation dose data from a clinical Co-60 unit fitted with a multileaf collimator (MLC) and modeled in the EGSnrc Monte Carlo system. An in house treatment planning program is used to calculate IMRT dose distributions. Conformal delivery in a single slice on a uniform phantom based on sequentially delivered pencil beams is verified by Gafchromic film. Volumetric dose distributions for Co-60 serial tomotherapy are then generated for typical clinical sites that had been treated at our clinic by conventional 6MV IMRT using Varian Eclipse treatment plans. The Co-60 treatment plans are compared with the clinical IMRT plans using conventional matrices such as dose volume histograms (DVH). Dose delivery based on simultaneously opened MLC leaves is also explored and a novel MLC segmentation method is proposed. In order to increase efficiency of dose calculations, a novel convolution based fluence model for treatment planning is also proposed. The ion chamber measurements showed that the Monte Carlo modeling of the beam data under the MIMiC MLC is accurate. The film measurements from the uniform phantom irradiations confirm that IMRT plans from our in-house treatment planning system

  9. Characteristics and locations of sources

    Energy Technology Data Exchange (ETDEWEB)

    Lahtinen, J.; Poellaenen, R.; Toivonen, H. [Finnish Centre for Radiation and Nuclear Safety, Helsinki (Finland)

    1997-12-31

    Ten artificial radiation sources were placed in the terrain in order to test the capability of airborne measuring teams to detect them. One of the sources was a line source, others were point sources (three of them collimated). The radionuclides used in the sources were {sup 60}Co, {sup 137}Cs, {sup 99m}Tc and {sup 192}Ir. The source activities ranged from about 26 MBq (one of the cobalt sources) to 0.56 TBq (iridium). (au).

  10. Characteristics and locations of sources

    Energy Technology Data Exchange (ETDEWEB)

    Lahtinen, J; Poellaenen, R; Toivonen, H [Finnish Centre for Radiation and Nuclear Safety, Helsinki (Finland)

    1998-12-31

    Ten artificial radiation sources were placed in the terrain in order to test the capability of airborne measuring teams to detect them. One of the sources was a line source, others were point sources (three of them collimated). The radionuclides used in the sources were {sup 60}Co, {sup 137}Cs, {sup 99m}Tc and {sup 192}Ir. The source activities ranged from about 26 MBq (one of the cobalt sources) to 0.56 TBq (iridium). (au).

  11. Gamma ray energy spectrum of a buried radioactive source

    Energy Technology Data Exchange (ETDEWEB)

    Massey, N B

    1957-07-01

    Because of current attempts to utilize airborne gamma-ray scintillation spectrometers as a means of detecting and identifying buried radioactive mineral deposits, it has become important to study the effects of multiple scattering on the gamma-ray energy spectrum of a source buried in a semi-infinite medium. A series of ten experiments was made. First a scintillation detector was located in air at a fixed distance above a 250 microcurie cobalt-60 source suspended in a large tank. The level of water was raised from 25 cm below the source to 50 cm above, and the gamma-ray energy spectrum was observed. It was found that the high energy portion of the cobalt-60 spectrum remained identifiable even when the source was submerged more than five half-lengths. Further, the ratio of the counting rate of the total incident gamma radiation to the counting rate of the primary 1.33 MeV radiation was found to be very nearly linearly proportional to the depth of water cover. This leads to an empirical method for determining the depth of burial of a cobalt-60 point source. (author)

  12. Cobalt

    International Nuclear Information System (INIS)

    Stolyarova, I.A.; Bunakova, N.Yu.

    1983-01-01

    The neutron-activation method for determining cobalt in rocks, polymetallic and iron ores and rockforming minerals at 2x10 -6 -5x10 -3 % content is developed. Cobalt determination is based on the formation under the effect of thermal neutrons of nuclear reactor of the 60 Co radioactive isotope by the 59 Co (n, γ) 60 Co reaction with radiation energy of the most intensive line of 1333 keV. Cobalt can be determined by the scheme of the multicomponent analysis from the sample with other elements. Co is determined in the solution after separation of all determinable by the scheme elements. The 60 Co intensity is measured by the mUltichannel gamma-spectrometer with Ge(Li)-detector

  13. Comparison of 60Cobalt and 192Iridium sources in high dose rate afterloading brachytherapy

    International Nuclear Information System (INIS)

    Richter, J.; Baier, K.; Flentje, M.

    2008-01-01

    Purpose: 60 Co sources with dimensions identical to those of 192 Ir have recently been made available in clinical brachytherapy. A longer half time reduces demands on logistics and quality assurance and perhaps costs. Material and Methods: Comparison of the physical properties of 60 Co and 192 Ir with regard to brachytherapy. Results: Required activities for the same air kerma rate are lower by a factor of 2.8 for 60 Co. Differential absorption in tissues of different densities can be neglected. Monte Carlo calculations demonstrate that integral dose due to radial dose fall off is higher for 192 Ir in comparison to 60 Co within the first 22 cm from the source (normalization at 1 cm). At larger distances this relationship is reversed. Conclusion: Clinical examples for intracavitary and interstitial applications however, show practically identical dose distributions in the treatment volume. (orig.)

  14. Development of irradiator 60Co sources

    International Nuclear Information System (INIS)

    Mosca, Rodrigo C.; Moura, Eduardo S.; Zeituni, Carlos A.; Mathor, Monica B.

    2011-01-01

    According to a recent report by the International Agency for Research on Cancer (IARC) / WHO (2008-2010), the global impact of cancer more than doubled in 30 years. In this report, it was estimated that occurred about 12 million new cancer cases and 7 million deaths. In Brazil in 2010, with estimates for the year 2011, point to the occurrence of 489,270 new cases of cancer. Among the possibilities for cancer treatment, radiotherapy is one of the most important therapeutic and resources used to combat it. However, inherent complications of treatment can occur such as tiredness, loss of appetite, radiodermatitis and in more extreme cases late radionecrosis. In order to reproduce a point of radionecrosis in the vicinity of radiodermatitis to mimic these effects in animals, producing a model for assessment of tissue repair, we propose the setting up of an irradiator source of collimated 60 Co. The development of was based on 11 sources of 60 Co with 1 mm thickness that were inserted by inference in stainless steel 'gate-source' screw (patent pending) and later adjusted in a cross-shaped arrangement reinforced so that the beam radiation is directed to a target point, saving for other regions around this target point. The main use of this irradiator with sources of 60 Co is just one cause radionecrosis point (target point) of approximately 5 mm 2 with a surrounding and adjacent area of radiodermatitis around about 8 to 10 mm 2 in laboratory animals for subsequent coating with epidermal-dermal matrix populated by a cell culture of human fibroblasts, keratinocytes and mesenchymal stem cells. With that said, its use will be valuable for evaluation of curative treatments against the bone and radionecrosis or palliative treatment rather than as it is currently assumed. (author)

  15. Field and laboratory evaluation of the mobility of cobalt-60/EDTA in an arid environment

    International Nuclear Information System (INIS)

    Jones, T.L.; Gee, G.W.; Swanson, J.L.; Kirkham, R.R.

    1983-02-01

    The ability of the organic complexant EDTA to enhance the mobility of cobalt-60 was investigated in both laboratory and field experiments. Laboratory tests consisted of short term (approximately 7 day) column and batch adsorption tests using soil from the Hanford site as well as long term (approximately 70 day) batch tests with Hanford soil and soils from Oak Ridge and Savannah River. In addition, two large scale tracer tests were conducted using Hanford soil. One used a large (1.6 m) laboratory column, spiked with cobalt-60/EDTA and the other was a field test conducted in an 8 m deep lysimeter. Enhanced mobility decreased sorption were observed in both column and batch tests when the cobalt-60/EDTA solutions contacted Hanford and Oak Ridge soil for only a few days. When long contact times were allowed (months) the Hanford soil showed large increases in sorption with time. The low sorption exhibited initially by the Oak Ridge soil increased slightly over time, however, the high sorption observed with the Savannah River soil remained constant with time. The reduced mobility, with time, observed in Hanford soils was confirmed in both the large scale laboratory and breaking down when contacted with Hanford and Savannah River soil and to a lesser extent, the Oak Ridge soil. It is not known at this time why the complex is breaking down or why the kinetics are different among the soils tested. The implication to waste management is that the potential for transport of cobalt by EDTA complexation may not be as serious as once thought

  16. Heating analysis of cobalt adjusters in reactor core

    International Nuclear Information System (INIS)

    Mei Qiliang; Li Kang; Fu Yaru

    2011-01-01

    In order to produce 60 Co source for industry and medicine applications in CANDU-6 reactor, the stainless steel adjusters were replaced with the cobalt adjusters. The cobalt rod will generate the heat when it is irradiated by neutron and γ ray. In addition, 59 Co will be activated and become 60 Co, the ray released due to 60 Co decay will be absorbed by adjusters, and then the adjusters will also generate the heat. So the heating rate of adjusters to be changed during normal operation must be studied, which will be provided as the input data for analyzing the temperature field of cobalt adjusters and the relative heat load of moderator. MCNP code was used to simulate whole core geometric configuration in detail, including reactor fuel, control rod, adjuster, coolant and moderator, and to analyze the heating rate of the stainless steel adjusters and the cobalt adjusters. The maximum heating rate of different cobalt adjuster based on above results will be provided for the steady thermal hydraulic and accident analysis, and make sure that the reactor is safe on the thermal hydraulic. (authors)

  17. Practical and clinical considerations in Cobalt-60 tomotherapy

    Directory of Open Access Journals (Sweden)

    Joshi Chandra

    2009-01-01

    Full Text Available Cobalt-60 (Co-60 based radiation therapy continues to play a significant role in not only developing countries, where access to radiation therapy is extremely limited, but also in industrialized countries. Howver, technology has to be developed to accommodate modern techniques, in-clud-ing image guided and adaptive radiation therapy (IGART. In this paper we describe some of the practical and clinical considerations for Co-60 based tomotherapy by comparing Co-60 and 6 MV linac-based tomotherapy plans for a head and neck (HandN cancer and a prostate cancer case. The tomotherapy IMRT plans were obtained by modeling a MIMiC binary multi-leaf collimator attached to a Theratron-780c Co-60 unit and a 6 MV linear accelerator (CL2100EX. The EGSnrc/BEAMnrc Monte Carlo (MC code was used for the modeling of the treatment units with the MIMiC collimator and EGSnrc/DOSXYZnrc code was used for beamlet dose data. An in-house inverse treatment planning program was then used to generate optimized tomotherapy dose distributions for the H and N and prostate cases. The dose distributions, cumulative dose area histograms (DAHs and dose difference maps were used to evaluate and compare Co-60 and 6 MV based tomotherapy plans. A quantitative analysis of the dose distributions and dose-volume histograms shows that both Co-60 and 6 MV plans achieve the plan objectives for the targets (CTV and nodes and OARs (spinal cord in HandN case, and rectum in prostate case.

  18. Effect of cobalt-60 gamma-ray irradiation on beans (Phaseolus vulgaris L.) of huasteco variety

    International Nuclear Information System (INIS)

    Navarro A, W.

    1984-01-01

    Bean seeds, Huasteco variety, were irradiated at 10, 20, 30 and 40 kR in a cobalt-60 gamma-ray source. Non-irradiated seeds were used as control. Irradiated and non-irradiated seeds were planted under greenhouse conditions using a random design and a population of 200 plants per treatment for both first and second generations (M 1 and M 2 ). The characters studied were; germination, survival, morphological changes of leaves and stem, change in seed coat colour, flowering, height, stem diameter, number of internodes, number of pods and number of seeds per pod. General plant behaviour was also observed to detect changes on a genic or chromosomic level. (M.A.C.) [pt

  19. Radiological shielding of cobalt-60 teletherapy facility at Komfo Anokye Teaching Hospital, Kumasi, Ghana

    International Nuclear Information System (INIS)

    Addison, E.K.T.; Kitcher, H.W.; Kyere, A.W.K.; Nani, E.K.

    2003-01-01

    The radiological shielding of the radiotherapy unit, oncology directorate, Komfo Anokye teaching hospital, has been assessed based on the workload and occupancy factors, in addition to the technical and performance specification of the cirus cobalt-60 equipment. Aspects relating to the design of treatment room were described. Calculations were based on NCRP report 49 and measurements were carried out on the structural shielding design of the cobalt-60 unit by the standard method prescribed in the NCRP report 49. This study was carried out to evaluate the adequacy of the shielding put in place to ensure the safety of the staff, public and oncological patients. The results obtained and measurements made, all fall below the regulatory effective dose limit of 20 mSv per year for staff and 1 mSv per year for the public (author)

  20. Cobalt

    Science.gov (United States)

    Slack, John F.; Kimball, Bryn E.; Shedd, Kim B.; Schulz, Klaus J.; DeYoung,, John H.; Seal, Robert R.; Bradley, Dwight C.

    2017-12-19

    Cobalt is a silvery gray metal that has diverse uses based on certain key properties, including ferromagnetism, hardness and wear-resistance when alloyed with other metals, low thermal and electrical conductivity, high melting point, multiple valences, and production of intense blue colors when combined with silica. Cobalt is used mostly in cathodes in rechargeable batteries and in superalloys for turbine engines in jet aircraft. Annual global cobalt consumption was approximately 75,000 metric tons in 2011; China, Japan, and the United States (in order of consumption amount) were the top three cobalt-consuming countries. In 2011, approximately 109,000 metric tons of recoverable cobalt was produced in ores, concentrates, and intermediate products from cobalt, copper, nickel, platinum-group-element (PGE), and zinc operations. The Democratic Republic of the Congo (Congo [Kinshasa]) was the principal source of mined cobalt globally (55 percent). The United States produced a negligible amount of byproduct cobalt as an intermediate product from a PGE mining and refining operation in southeastern Montana; no U.S. production was from mines in which cobalt was the principal commodity. China was the leading refiner of cobalt, and much of its production came from cobalt ores, concentrates, and partially refined materials imported from Congo (Kinshasa).The mineralogy of cobalt deposits is diverse and includes both primary (hypogene) and secondary (supergene) phases. Principal terrestrial (land-based) deposit types, which represent most of world’s cobalt mine production, include primary magmatic Ni-Cu(-Co-PGE) sulfides, primary and secondary stratiform sediment-hosted Cu-Co sulfides and oxides, and secondary Ni-Co laterites. Seven additional terrestrial deposit types are described in this chapter. The total terrestrial cobalt resource (reserves plus other resources) plus past production, where available, is calculated to be 25.5 million metric tons. Additional resources of

  1. Research and design of the moving system for the cobalt-60 industrial irradiator

    International Nuclear Information System (INIS)

    Le Minh Tuan; Tran Khac An; Cao Van Chung; Phan Phuoc Thang

    2016-01-01

    On the way of localization of Cobalt-60 industrial irradiators, Research and Development Center for Radiation Technology (VINAGAMMA) has successfully designed and manufactured the first version of Co-60 industrial irradiator, VINAGA1. The second version of Co-60 industrial irradiator has been studied and designed by VINAGAMMA in the frame of the scientific project No. DTCB.02/15/TTNCTK. The nucleus of a Co-60 industrial irradiator is a mechanical system inside an irradiation room namely a tote box moving system. This report presents the tote box moving system designed by VINAGAMMA. The tote box moving system contains 52 tote boxes with the dimensions of 50 cm (w) × 70 cm (l) × 150 cm (h) that are moving around the source racks in the manner of 4 passes and 2 levels. The irradiator with this tote box moving system has good specifications: The minimum time of an irradiation cycle is 1h 20 min and the dose uniformity ratio (DUR) at the product densities of 0.1 g/cm 3 and 0.5 g/cm 3 is 1.4 and 1.8, respectively. Radiation energy utilization efficiency at the product densities of 0.1 g/cm 3 and 0.5 g/cm 3 is 19.7% and 48.8%, respectively. These specifications meet the requirements for a multi-purpose Co-60 industrial irradiator and the present irradiation requirements in Vietnam. (author)

  2. Direct uptake of cobalt 60 by the carp (Cyprinus carpio L.) following experimental chronic or cyclical contamination of water

    International Nuclear Information System (INIS)

    Amiard-Triquet, C.; Foulquier, L.

    1978-01-01

    Irrespective of the nature of experimental cobalt 60 contamination (chronic or cyclical), the activity level in the carp was highest after 32 or 35 days when the concentration factor reached 3. An analysis of cobalt 60 distribution shows preferential uptake by the kidneys. It therefore seems unlikely that the discharge rate of effluents from the nuclear industry and the resulting variations of radioactivity levels in the water significantly modify the impact of contamination on aquatic organisms [fr

  3. Development of irradiator {sup 60}Co sources

    Energy Technology Data Exchange (ETDEWEB)

    Mosca, Rodrigo C.; Moura, Eduardo S.; Zeituni, Carlos A.; Mathor, Monica B., E-mail: rcmosca@usp.b [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2011-07-01

    According to a recent report by the International Agency for Research on Cancer (IARC) / WHO (2008-2010), the global impact of cancer more than doubled in 30 years. In this report, it was estimated that occurred about 12 million new cancer cases and 7 million deaths. In Brazil in 2010, with estimates for the year 2011, point to the occurrence of 489,270 new cases of cancer. Among the possibilities for cancer treatment, radiotherapy is one of the most important therapeutic and resources used to combat it. However, inherent complications of treatment can occur such as tiredness, loss of appetite, radiodermatitis and in more extreme cases late radionecrosis. In order to reproduce a point of radionecrosis in the vicinity of radiodermatitis to mimic these effects in animals, producing a model for assessment of tissue repair, we propose the setting up of an irradiator source of collimated {sup 60}Co. The development of was based on 11 sources of {sup 60}Co with 1 mm thickness that were inserted by inference in stainless steel 'gate-source' screw (patent pending) and later adjusted in a cross-shaped arrangement reinforced so that the beam radiation is directed to a target point, saving for other regions around this target point. The main use of this irradiator with sources of {sup 60}Co is just one cause radionecrosis point (target point) of approximately 5 mm{sup 2} with a surrounding and adjacent area of radiodermatitis around about 8 to 10 mm{sup 2} in laboratory animals for subsequent coating with epidermal-dermal matrix populated by a cell culture of human fibroblasts, keratinocytes and mesenchymal stem cells. With that said, its use will be valuable for evaluation of curative treatments against the bone and radionecrosis or palliative treatment rather than as it is currently assumed. (author)

  4. Conceptual design of a conveyor system for the Philippine multipurpose cobalt-60 gamma irradiation facility

    International Nuclear Information System (INIS)

    Borras, A.M.

    1992-01-01

    The Multipurpose Cobalt-60 Gamma Irradiation Facility at the PNRI presently utilizes the batch irradiation method using turntables to rotate the product boxes. The target materials or products are being carried manually or with the use of pushcart through the personnel maze. This paper presents a conceptual design for the best suitable product-handling or conveyor system for the Philippine Multipurpose Cobalt-60 Gamma Irradiation Facility. The main irradiation conveyor line shall be a 55 cm x 200 cm slat-type conveyor made of SUS 304 material that could be operated in a semi-batch continuous flow and/or shuffle-dwell method with a tact-time range of 10 min to 7 h. The products can be irradiated in a single direction, two-pass, two-sided method. (auth.). 11 refs.; 4 figs.; 2 tabs

  5. The cobalt radioactive isotopes in environment

    International Nuclear Information System (INIS)

    2007-01-01

    For the year 1993 the total activity released in cobalt is 69 GBq for the whole of nuclear power plants. The part of activity in cobalt for La Hague in 1993 is 8 GBq of 58 Co and 2 GBq of 60 Co. The radioactive isotopes released by nuclear power plants or the reprocessing plant of La Hague under liquid effluents are shared by half between 58 Co and 60 Co. The exposure to sealed sources is the most important risk for the cobalt. The risk of acute exposure can associate a local irradiation of several decades of grays inducing a radiological burns, deep burn to treat in surgery by resection or graft even amputation. A global irradiation of organism for several grays induces an acute irradiation syndrome, often serious. At long term the stochastic effects are represented by leukemia and radio-induced cancers. The increase of probability of their occurrence is 1% by sievert. We must remind that the natural spontaneous probability is 25%. (N.C.)

  6. The cobalt radioactive isotopes in environment; Les isotopes radioactifs du cobalt dans l'environnement

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2007-07-01

    For the year 1993 the total activity released in cobalt is 69 GBq for the whole of nuclear power plants. The part of activity in cobalt for La Hague in 1993 is 8 GBq of {sup 58}Co and 2 GBq of {sup 60}Co. The radioactive isotopes released by nuclear power plants or the reprocessing plant of La Hague under liquid effluents are shared by half between {sup 58}Co and {sup 60}Co. The exposure to sealed sources is the most important risk for the cobalt. The risk of acute exposure can associate a local irradiation of several decades of grays inducing a radiological burns, deep burn to treat in surgery by resection or graft even amputation. A global irradiation of organism for several grays induces an acute irradiation syndrome, often serious. At long term the stochastic effects are represented by leukemia and radio-induced cancers. The increase of probability of their occurrence is 1% by sievert. We must remind that the natural spontaneous probability is 25%. (N.C.)

  7. Computer generation of cobalt-60 single beam dose distribution using an analytical beam model

    International Nuclear Information System (INIS)

    Jayaraman, S.

    1981-01-01

    A beam dose calculation model based on evaluation of tissue air ratios (TAR) and scatter air ratios (SAR) for cobalt-60 beams of rectangular cross section has been developed. Off-central axis fall-off of primary radiation intensity is derived by an empirical formulation involving an arctangent function with the slope of the geometrical penumbra acting as an essential constant. Central axis TAR and SAR values are assessed by semi-empirical polynomial expressions employing the two sides of the rectangular field as the bariables. The model utilises a minimum number of parametric constants and is useful for computer generation of isodose curves. The model is capable of accounting for situations where wedge filters or split field shielding blocks, are encountered. Further it could be widely applied with minor modifications to several makes of the currently available cobalt-60 units. The paper explains the model and shows examples of the results obtained in comparison with the corresponding experimentally determined dose distributions. (orig.) [de

  8. Development of a Cloud-Point Extraction Method for Cobalt Determination in Natural Water Samples

    Directory of Open Access Journals (Sweden)

    Mohammad Reza Jamali

    2013-01-01

    Full Text Available A new, simple, and versatile cloud-point extraction (CPE methodology has been developed for the separation and preconcentration of cobalt. The cobalt ions in the initial aqueous solution were complexed with 4-Benzylpiperidinedithiocarbamate, and Triton X-114 was added as surfactant. Dilution of the surfactant-rich phase with acidified ethanol was performed after phase separation, and the cobalt content was measured by flame atomic absorption spectrometry. The main factors affecting CPE procedure, such as pH, concentration of ligand, amount of Triton X-114, equilibrium temperature, and incubation time were investigated and optimized. Under the optimal conditions, the limit of detection (LOD for cobalt was 0.5 μg L-1, with sensitivity enhancement factor (EF of 67. Calibration curve was linear in the range of 2–150 μg L-1, and relative standard deviation was 3.2% (c=100 μg L-1; n=10. The proposed method was applied to the determination of trace cobalt in real water samples with satisfactory analytical results.

  9. Cobalt 60 cation exchange with mexican clays

    International Nuclear Information System (INIS)

    Nava Galve, R.G.

    1993-01-01

    Mexican clays can be used to remove radioactive elements from contaminated aqueous solutions. Cation exchange experiments were performed with 60 Co radioactive solution. In the present work the effect of contact time on the sorption of Co 2+ was studied. The contact time in hydrated montmorillonite was from 5 to 120 minutes and in dehydrated montmorillonite 5 to 1400 minutes. The Co 2+ uptake value was, in hydrated montmorillonite, between 0.3 to 0.85 m eq/g and in dehydrated montmorillonite, between 0.6 to 1.40 m eq/g. The experiments were done in a pH 5.1 to 5.7 and normal conditions. XRD patterns were used to characterize the samples. The crystallinity was determined by X-ray Diffraction and it was maintained before and after the cation exchange. DTA thermo grams showed the temperatures of the lost humidity and crystallization water. Finally, was observed that dehydrated montmorillonite adsorb more cobalt than hydrated montmorillonite. (Author)

  10. Effect of cobalt on the growth of Trichoderma viride and determination of its distribution using 60Co

    International Nuclear Information System (INIS)

    Frank, V.; Lesny, J.; Babej, L.

    1993-01-01

    The growth and morphology of filamentous fungus Trichoderma viride grown in the presence of various Co concentrations were studied. Using 60 Co, the cobalt content in mycelium and conidia was determined. No influence of 60 Co-radiation on growth and morphology was observed. (author) 5 refs.; 4 figs

  11. Development of a new model of actinic enteritis in rats using a cobalt-60 open source and a protection device as a collimator

    Energy Technology Data Exchange (ETDEWEB)

    Nunes, Vinicius Rodrigues Taranto; Vidigal, Paula Vieira Teixeira; Barbuto, Rafael Calvao; Duval-Araujo, Ivana, E-mail: vivas1912@hotmail.com [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte (UFMG), MG (Brazil); Pereira, Marcio Tadeu; Ladeira, Luis Carlos Duarte [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil)

    2017-03-15

    Purpose: To describe a new model of actinic enteritis that does not use radiotherapy machines. Methods: Sixteen Wistar rats were divided into four groups, consisting of four animals each: control (group A), two weeks after irradiation (group B), five weeks after irradiation (group C) and eight weeks after irradiation (group D). Animals were given a 10Gy radiation from a Cobalt-60 natural source in a nuclear technology research center. Protections of the surrounding tissues were obtained through the usage of plumb devices with a hole in the center, which served as a collimator. We obtained irradiated and non-irradiated colons from each animal. Results: In group B we found an important inflammatory response in the irradiated colon, which appeared in a reduced way in group C and was minimal in group D, in which we found a relevant collagen submucosal deposition/fibrosis. In all groups, the non-irradiated colon had a lower pathological damage in comparison with the irradiated colon. Conclusion: We thus described an efficient and feasible technique for obtaining an animal model of actinic enteritis. (author)

  12. Effect of cobalt-60 irradiation on the developing tooth germ of rat

    Energy Technology Data Exchange (ETDEWEB)

    You, Dong Soo; Lee, Ki Sik [Department of Dental Radiology, Graduate School, Seoul National University, Seoul (Korea, Republic of)

    1976-11-15

    The author observed the effects of the cobalt-60 irradiation on the amelogenesis and dentinogenesis of the albino rat fetuses by means of histological and histochemical methods. Female in oestrus were mated overnight and examined the next morning for evidence of copulation. The lower left abdomen of mothers were exposed to cobalt-60 irradiation on the 10th day of gestation, 100R 200R and 300R respectively. The fetuses were removed from the mothers on the 18th day of gestation. The employed histochemical methods were PAS reaction, colloidal iron reaction, aldehyde fuchsin stain, -amino acid reaction, -SH radical reaction, and methyl green pyronin stain. The results were as follows; 1. The group irradiated by 100R made no histological differences in comparison with the control group. 2. Increasing the irradiation to 200R, abnormal dentin formation occurred, and resulted in enamel hypoplasia, atrophy, and necrosis of odontoblasts. In dentinal papilla, the dilation and the degeneration of the blood vessels, excessive reticular atrophy, and osteodentin were revealed. 3. With the more irradiation (200R-300R), the positive material of PAS, {alpha}-amino acid and aldehyde fuchsin tended to decrease in the ameloblast and in the odontoblast. No significant changes appeared in DNA, the stainability of methylgreen pyronin.

  13. Effect of cobalt-60 irradiation on the developing tooth germ of rat

    International Nuclear Information System (INIS)

    You, Dong Soo; Lee, Ki Sik

    1976-01-01

    The author observed the effects of the cobalt-60 irradiation on the amelogenesis and dentinogenesis of the albino rat fetuses by means of histological and histochemical methods. Female in oestrus were mated overnight and examined the next morning for evidence of copulation. The lower left abdomen of mothers were exposed to cobalt-60 irradiation on the 10th day of gestation, 100R 200R and 300R respectively. The fetuses were removed from the mothers on the 18th day of gestation. The employed histochemical methods were PAS reaction, colloidal iron reaction, aldehyde fuchsin stain, -amino acid reaction, -SH radical reaction, and methyl green pyronin stain. The results were as follows; 1. The group irradiated by 100R made no histological differences in comparison with the control group. 2. Increasing the irradiation to 200R, abnormal dentin formation occurred, and resulted in enamel hypoplasia, atrophy, and necrosis of odontoblasts. In dentinal papilla, the dilation and the degeneration of the blood vessels, excessive reticular atrophy, and osteodentin were revealed. 3. With the more irradiation (200R-300R), the positive material of PAS, α-amino acid and aldehyde fuchsin tended to decrease in the ameloblast and in the odontoblast. No significant changes appeared in DNA, the stainability of methylgreen pyronin.

  14. Reducing plant radiation fields by source term reduction - tracking cobalt and antimony to their sources at Gentilly-2

    International Nuclear Information System (INIS)

    Gauthier, P.; Guzonas, D.A.

    2006-01-01

    Gentilly-2 NGS is experiencing high radiation fields in the fuelling machine vaults. These high fields make maintenance outages more expensive and their management more complicated. As part of the station refurbishment project, a task group was created to identify the cause of the high fields and make recommendations to prevent their reoccurrence in the second (post-refurbishment) operating cycle. To identify the root cause of the problem, the task group decided to analyse the primary heat transport system (PHTS), the fuel handling system and their inter-relation. Gentilly-2 has had to manage a unique (to CANDU) problem arising from antimony released from the main heat transport pump seals. Antimony deposits on in-core surfaces, becomes activated, and subsequently can be released, especially under oxidizing coolant conditions. It then becomes incorporated into the magnetite deposits on PHTS piping, including the steam generators and inlet feeders. Gentilly-2 has focused a great deal of effort on managing antimony over the last 15 years. As a result of these initiatives, radioantimony fields have been quite effectively managed since 1997, resulting in a decrease in their relative contribution to the total fields. The decrease in radioantimony fields highlighted the significant contribution of 60 Co cobalt activity; the high levels of both radioantimony and 60 Co differentiate Gentilly-2 from other CANDU 6 plants. Two types of 59 Co sources are present in the CANDU PHTS. High surface area materials such as steam generator tubes and feeder pipes contain trace concentrations of 59 Co as an impurity, which can be released by corrosion. Low surface area materials such as Stellites contain high concentrations of 59 Co that can be released as either corrosion or wear products. After assessing potential cobalt sources, the task group concluded that PHTS materials were not likely the origin of the high 60 Co fields. The major PHTS components identified as cobalt sources have

  15. Optimization of point sources on thin films using a statistical design approach. Application to {sup 60}Co sources; Optimisation des sources ponctuelles sur film mince par une approche experimentale de type plan d'experiences. Application aux sources de {sup 60}Co

    Energy Technology Data Exchange (ETDEWEB)

    Sanoit, J.; Leprince, B. [CEA Saclay, Dept. d' Instrumentation et de Metrologie des Rayonnements Ionisants, 91 - Gif sur Yvette (France); Vailhen, D. [CEA Saclay, Dir. de la Surete Nucleaire et de la Qualite, 91 - Gif sur Yvette (France)

    2001-07-01

    Radioactive point sources prepared by depositing weighed drops on thin membranes are commonly used in ionizing radiation metrology for 47{pi}{beta}-{gamma} coincidence counting or for low energy electrons spectrometry. The present study deals with the preparation of good quality sources having high detection yields. Some influential parameters on the source quality are studied using {sup 60}Co as radioactive tracer. An approach based on experimental statistical designs has been chosen. This approach allows us to obtain reliable results with a number of experiences lower than in the case of a systematic approach. Homogeneous {sup 60}Co sources with high metrological qualifies (R{sub {beta}}> 96 %) can be prepared using a direct deposit of {approx} 5 mg drops of {sup 60}Co solution ([Co] = 12 {mu}g/g, [HCl] = 0,5 mol/I) and dried at 60 deg C. The support of the radioactive spot is constituted with a gold coated (130 {mu}g/cm{sup 2} of Au) Vyns films (thickness 45 {mu}g/cm{sup 2}) on which a pad (diameter = 7 - 8 mm) of polystyrene microspheres (Estapor K-007) is prepared by an electro-spraying technique under 7,5 kV during 10 minutes. The alcoholic solution used for the electro-spraying step has the following chemical composition [Estapor K-007] 2.5 10{sup -2} wt % and [Tween 20] = 2.7 10{sup -2} wt %. (authors)

  16. Dosimetric intercomparison in Cobalt 60 unities using TLD-100 crystals and CaSO{sub 4}: Dy + Ptfe; Intercomparacion dosimetrica en unidades de cobalto 60 usando cristales de TLD-100 y CaSO{sub 4}: Dy + PTFE

    Energy Technology Data Exchange (ETDEWEB)

    Gaona, E. [Universidad Autonoma Metropolitana Xochimilco, Mexico D.F. (Mexico); Azorin N, J. [Universidad Autonoma Metropolitana Iztapalapa, Mexico D.F. (Mexico); Perez P, M.A. [Instituto Nacional de Cancerologia, Mexico D.F. (Mexico); Castillo H, M. [Centro Medico Nacional 20 de Noviembre, ISSSTE, Mexico D.F. (Mexico); Flores F, F. [Unidad de Oncologia, Centro Medico Nacional, IMSS, Mexico D.F. (Mexico); Guzman R, L.V. [Unidad de Oncologia, Hospital General de Mexico, Mexico D.F. (Mexico)

    1999-07-01

    The purpose of this work is to design and construct a phantom in basis of thermoplastic polymer of methyl methacrylate that is reutilizable and which allows to do an analysis of the absorbed doses in thermoluminescent crystals (Tl) exposed to cobalt 60 to establish the dosimetric intercomparison in cobalt units which allows to do the follow-up of the Quality assurance programs, standardization of calibration procedures, dosimetry and TLD post intercomparison in radiotherapy. This work allows also prove new thermoluminescent materials of national manufacture developed by Juan Azorin and collaborators as the CaSO{sub 4}: Dy + Ptfe. This is a first study which is realized in Mexico with the system crystal-phantom for aims to intercomparison in cobalt 60 units. In this work participate eight unities of cobalt 60 of different trades belonging at four radiotherapy centers. The results of the dose intercomparison of the eight unities of cobalt 60 were in the range 0.95-1.13, taking in account that the values between 0.95 and 1.05 were considered acceptable in terms of the requirements by the standing legislation. (Author)

  17. Cobalt alloy ion sources for focused ion beam implantation

    Energy Technology Data Exchange (ETDEWEB)

    Muehle, R.; Doebeli, M. [Paul Scherrer Inst. (PSI), Villigen (Switzerland); Zimmermann, P. [Eidgenoessische Technische Hochschule, Zurich (Switzerland)

    1997-09-01

    Cobalt alloy ion sources have been developed for silicide formation by focused ion beam implantation. Four eutectic alloys AuCo, CoGe, CoY and AuCoGe were produced by electron beam welding. The AuCo liquid alloy ion source was investigated in detail. We have measured the emission current stability, the current-voltage characteristics, and the mass spectrum as a function of the mission current. (author) 1 fig., 2 refs.

  18. The use of radioactive sources for the study of wear in refractory linings; L'emploi de sources radioactives pour l'etude de l'usure des revetements refractaires

    Energy Technology Data Exchange (ETDEWEB)

    Courtois, G; Hours, R [Commissariat a l' Energie Atomique, Saclay (France).Centre d' Etudes Nucleaires

    1960-07-01

    Following a discussion on the radioactive method for studying wear in refractory linings (description of the method, advantages and disadvantages, choice of radioactive indicator and detection), the article deals in some detail with the problems of safety involved in this technique. The two most important points discussed are: 1- the need to fix an upper limit of activity in the cast iron: the authors propose a figure of 1 mc of cobalt 60 in 500 tons; 2- the precautions necessary to remedy the diffusion of cobalt 60 in the brickwork (development of special pyro-ceramic sources). After a discussion on the international view point regarding the use of the method, a brief outline of some French projects is given, with particular reference to the case of a blast furnace. A note from the Commission interministerielle des Radioelements is given as an appendix; this deals with special conditions laid down for the use of radioelements in the determination of wear in refractory walls. (author) [French] Apres avoir discute de la methode radioactive pour l'etude de l'usure des revetements refractaires (description de la methode, avantages et inconvenients, choix de l'indicateur radioactif et detection), l'article traite plus particulierement des problemes de securite intervenant dans cette application. Les deux points les plus importants discutes dans ce rapport sont: 1- la necessite de fixer l'activite limite de la fonte et les auteurs proposent ici le chiffre de 1 mc de cobalt 60 dans 500 tonnes de fonte; 2- les remedes a apporter a la diffusion du cobalt 60 dans la maconnerie (realisation de sources speciales en pyrocerame). Apres avoir examine le point de vue international sur l'utilisation de la methode, l'article decrit brievement quelques realisations francaises en etudiant plus particulierement le cas d'un haut-fourneau. En annexe, se trouve une note de la Commission interministerielle des Radio-elements traitant des conditions particulieres d'emploi des radio

  19. Unidentified point sources in the IRAS minisurvey

    Science.gov (United States)

    Houck, J. R.; Soifer, B. T.; Neugebauer, G.; Beichman, C. A.; Aumann, H. H.; Clegg, P. E.; Gillett, F. C.; Habing, H. J.; Hauser, M. G.; Low, F. J.

    1984-01-01

    Nine bright, point-like 60 micron sources have been selected from the sample of 8709 sources in the IRAS minisurvey. These sources have no counterparts in a variety of catalogs of nonstellar objects. Four objects have no visible counterparts, while five have faint stellar objects visible in the error ellipse. These sources do not resemble objects previously known to be bright infrared sources.

  20. Research and design of the moving system for the cobalt-60 industrial irradiator VINAGA2

    International Nuclear Information System (INIS)

    Le Minh Tuan; Tran Khac An; Nguyen Ngoc Phuong; Tran Van Hung; Cao Van Chung; Phan Phuoc Thang; Ha Thanh Viet; Nguyen Thanh Cuong; Nguyen Duc Hoa

    2017-01-01

    On the way of localization of Cobalt-60 industrial irradiators, Research and Development Center for Radiation Technology (VINAGAMMA) has successfully designed and manufactured the first version of Co-60 industrial irradiator, VINAGA1. The second version of Co-60 industrial irradiator has been studied and designed by VINAGAMMA in the frame of the scientific project No. DTCB.02/15/TTNCTK. The main system of a Co-60 industrial irradiator is a mechanical system inside an irradiation room namely a tote box moving system. This report presents the tote box moving system of VINAGA2 designed by VINAGAMMA. The tote box moving system contains 52 tote boxes with the dimensions of 50 cm (w) × 70 cm (l) × 150 cm (h) that are moving around the source racks in the manner of 4 passes and 2 levels. The irradiator VINAGA2 with this tote box moving system has good specifications: The minimum time of an irradiation cycle is 1 h 20 min. and the dose uniformity ratio (DUR) at the product densities of 0.1 g/cm 3 and 0.5 g/cm 3 is 1.4 and 1.8, respectively. Radiation energy utilization efficiency at the product densities of 0.1 g/cm 3 and 0.5 g/cm 3 is 19.7% and 48.8%, respectively. These specifications meet the requirements for a multi-purpose Co-60 industrial irradiator and the present irradiation requirements in Vietnam. (author)

  1. Influence of source configuration on spectral composition of gamma-ray beams from 60Co teletherapy units

    International Nuclear Information System (INIS)

    Ehrlich, M.; Soares, C.G.; Jackson, B.; Lanoue, P.

    1978-01-01

    Measurements were made of the photon spectra of simulated 60 Co teletherapy beams. Various source configurations and source environments of practical interest were employed for this purpose. The sources consisted of activated cobalt pellets packed into steel capsules. Several combinations of capsule diameters and heights of pellet layers were used. The spacer materials filling the remaining capsule volume were chosen to be of high, intermediate, or low atomic number. The capsules could be inserted, one at a time, into a compartment of either tungsten or brass, simulating the central section of popular commercial 60 Co teletherapy units. There also was some choice in the atomic number of the structural elements holding the capsules in place in the compartment. The largest contribution of scattered photons was found to occur when the materials close to the source pellets had atomic numbers in the vicinity of 30. (author)

  2. Repacking of Cobalt 60 spent sources in the central interim storage

    International Nuclear Information System (INIS)

    Zeleznik, N.

    2003-01-01

    After the transfer of the responsibility for the management of the Central interim storage for waste from small producers, located at the reactor centre in Brinje near Ljubljana, Slovenia, the national Agency for radwaste management (ARAO) started with most urgent activities to improve the utilization of the storage facility. One of the main tasks has also been the rearrangement of the already stored radioactive waste in order to reduce volume of the waste and to collect same radioisotopes in the containers. The latest campaign, performed in 2002/2003, was repacking of all Co-60 spent sealed sources in the storage facility and also at the producer's premises which were after conditioning put into two drums with concrete matrix and stored back to the Central interim storage. The preparation works together with the implementation are described in the paper. (author)

  3. Comparison of skin doses to large fields using tangential beams from cobalt-60 gamma rays and 4-MV x rays

    International Nuclear Information System (INIS)

    Gagnon, W.F.; Peterson, M.D.

    1978-01-01

    Excess radiation to the skin during external beam megavoltage radiation therapy has reportedly caused excessive erythema in patients treated with the Clinac 4 linear accelerator on sloping surfaces, but not for similar treatments with cobalt-60. Doses at the epidermal level were measured under geometries simulating sloping surfaces for a Clinac 4 and an Eldorado 8 cobalt-60 teletherapy machine. For equal doses to the axilla, doses to the epidermal layer were similar. When the tumor dose was calculated for the mediastinum, the dose to the skin in the axillary region was 12% higher for the Clinac 4

  4. The dosimetry of cobalt-60 γ-ray total body irradiation before bone marrow transplantation

    International Nuclear Information System (INIS)

    Dong Fan; Zhang Guiru

    1989-11-01

    The dosimetric considerations of using conventional cobalt-60 unit total body irradiation (TBI) are presented. By extending the source-to-midplane distance (SMD) to 346 cm, a 92 x 98 cm 2 rectangular field with diagonal dimension 134 cm was obtained. The results from the phantom measurements showed: (1) the effective field corresponding to an average-size patient is 25 x 25 cm 2 , and a method for estimating the effective field of human body is given; (2) the midplane doses are consistently higher than those of surfaces, but the dose ratio of midplane to surface decreases as the body thickness increases, and a significant negative correlation is existed between the dose ratio and thickness, thus a linear regression line is fitted; (3) the anterior-posterior (AP) or AP + bilateral irradiation will yield a more uniform dose distribution in the whole body than the bilateral irradiation; (4) the dose uniformity can apparently be improved by the tissue compensation, for which the technique is described

  5. SSDL Argentina: Dosimetric intercomparison programme for cobalt 60 therapy units

    Energy Technology Data Exchange (ETDEWEB)

    Saravi, M; Papadopulos, S; Mugliaroli, H [Comision Nacional de Energia Atomica, Buenos Aires (Argentina)

    1996-08-01

    Thermoluminescence dosimeters (TLD) are widely used to verify absorbed dose delivered from radiation therapy beams. The Secondary Standard Dosimetry Laboratory (SSDL) of Argentina uses TLD for its mailed dose intercomparison programme for cobalt 60 radiation therapy units. Results obtained since 1978 as well as causes of dose discrepancies greater than 5% are analyzed. Results of the external quality control performed by the IAEA for this programme indicate that the dose evaluated by the SSDL TLD service for the participating centers is about 1% lower than that evaluated by the IAEA TLD service. This deviation is accepted taking on account that a {+-} 2% dose uncertainty for TLD dosimetry is reasonable. (author). 5 refs, 5 figs, 2 tabs.

  6. Regression of uveal malignant melanomas following cobalt-60 plaque. Correlates between acoustic spectrum analysis and tumor regression

    International Nuclear Information System (INIS)

    Coleman, D.J.; Lizzi, F.L.; Silverman, R.H.; Ellsworth, R.M.; Haik, B.G.; Abramson, D.H.; Smith, M.E.; Rondeau, M.J.

    1985-01-01

    Parameters derived from computer analysis of digital radio-frequency (rf) ultrasound scan data of untreated uveal malignant melanomas were examined for correlations with tumor regression following cobalt-60 plaque. Parameters included tumor height, normalized power spectrum and acoustic tissue type (ATT). Acoustic tissue type was based upon discriminant analysis of tumor power spectra, with spectra of tumors of known pathology serving as a model. Results showed ATT to be correlated with tumor regression during the first 18 months following treatment. Tumors with ATT associated with spindle cell malignant melanoma showed over twice the percentage reduction in height as those with ATT associated with mixed/epithelioid melanomas. Pre-treatment height was only weakly correlated with regression. Additionally, significant spectral changes were observed following treatment. Ultrasonic spectrum analysis thus provides a noninvasive tool for classification, prediction and monitoring of tumor response to cobalt-60 plaque

  7. An economic benefit analysis on the cobalt-60 irradiation facility of Beijing Radiation Research Center

    International Nuclear Information System (INIS)

    Wang Binlin

    1995-01-01

    The peculiarity, the investment and annual operating cost of the 3.7 x 10 16 Bq (MCi) cobalt-60 irradiation facility at Beijing Radiation Application Research Centre are described. Its economic benefits each year are analyzed according to several year operating practice. Some related questions on carrying out radiation processing are raised and discussed. (author)

  8. Separation of iron and cobalt using 59Fe and 60Co by dialysis of polyvinylpyrrolidone-metal complexes: A greener approach

    International Nuclear Information System (INIS)

    Lahiri, Susanta; Sarkar, Soumi

    2007-01-01

    An environmentally benign method to separate iron and cobalt has been developed using a safe chemical, polyvinylpyrrolidone (PVP). The method involves dialysis of PVP-Fe and PVP-Co complexes against triple-distilled water. 59 Fe and 60 Co were used as radioactive tracers of iron and cobalt throughout the experiment. No other chemicals are required for clean separation of cobalt from iron. The optimum condition for separation has been obtained at pH 5 using 10% aqueous solution of PVP. The method is applicable from trace scale to macro-scale. Very high separation factors have been obtained

  9. Evaluation of shelf life of tomatoes after using radiation with cobalt-60 source

    Energy Technology Data Exchange (ETDEWEB)

    Vicalvi, Maria Claudia V.; Solidonio, Evelyne G.; Melo, Patryk; Silva, Marcio Albuquerque da; Junior, Carlos Eduardo de O.C.; Silva, Glezia Renata da; Sena, Kesia Xisto F.R. de; Colaco, Waldeciro, E-mail: claudiavicalvi@hotmail.com, E-mail: k.xisto@gmail.com, E-mail: wcolaco@ufpe.com.br [Universidade Federal de Pernanbuco (UFPE), Pernambuco, PE (Brazil)

    2013-07-01

    Tomato is one of the most consumed fruits in the world and also one of the agricultural products with most losses due to its high perishability. The objective of this research was to evaluate the increased length of shelf life of tomatoes sold in the CEASA-PE through the use of radiation in doses of 1, 1.5 and 2 kGy with Cobalt-60 source. The study used three lots of 100 tomatoes each. Of which, 25 of them were used as the control group and 75 were irradiated with one of 3 different doses. The evaluation of the shelf life of tomatoes before and after use of the radiation was made from the observation of the visual aspects of the initiation of the fruit sto decay. The samples were analyzed at of every seven days. The fruit treated as the control group of the first batch were viable with no signs of decay for more than one month wrapped in sterile plastic wrap and stored at environment temperature ± 25 deg C. It was observed that at the dose of 1.0 kGy there was a delay in the induction of shelf life over 14 days. When used a dose of 1.5 kGy there was an increase of 30 days on shelf life compared with the control group. At a dose of 2.0 kGy, the tomatoes have a shelf life of 92 days. In the second batch of fruits, the duration of tomatoes of the control group was 40 days. At a dose of 1.0 kGy was an increase of 15 days compared to control fruits. When applying the dose of 1.5 kGy, the lifetime of the fruit was 70 days and at the dose of 2.0 kGy fruits were of 106 days starting from the initial date of experiment. The third and final batch,the lifetime of the fruits were not higher than those found in previous batches, the control group had a permanence of 14 days. At the dose of 1.0 kGy, there was the additional 10 days compared to the control group. At a dose of 1.5 kGy was observed that the fruits lasted 35 days starting from the initial day of the experiment and the tomatoes that were irradiated at 2.0 kGy the duration was 45 days from the start date of the

  10. Evaluation of shelf life of tomatoes after using radiation with cobalt-60 source

    International Nuclear Information System (INIS)

    Vicalvi, Maria Claudia V.; Solidonio, Evelyne G.; Melo, Patryk; Silva, Marcio Albuquerque da; Junior, Carlos Eduardo de O.C.; Silva, Glezia Renata da; Sena, Kesia Xisto F.R. de; Colaco, Waldeciro

    2013-01-01

    Tomato is one of the most consumed fruits in the world and also one of the agricultural products with most losses due to its high perishability. The objective of this research was to evaluate the increased length of shelf life of tomatoes sold in the CEASA-PE through the use of radiation in doses of 1, 1.5 and 2 kGy with Cobalt-60 source. The study used three lots of 100 tomatoes each. Of which, 25 of them were used as the control group and 75 were irradiated with one of 3 different doses. The evaluation of the shelf life of tomatoes before and after use of the radiation was made from the observation of the visual aspects of the initiation of the fruit sto decay. The samples were analyzed at of every seven days. The fruit treated as the control group of the first batch were viable with no signs of decay for more than one month wrapped in sterile plastic wrap and stored at environment temperature ± 25 deg C. It was observed that at the dose of 1.0 kGy there was a delay in the induction of shelf life over 14 days. When used a dose of 1.5 kGy there was an increase of 30 days on shelf life compared with the control group. At a dose of 2.0 kGy, the tomatoes have a shelf life of 92 days. In the second batch of fruits, the duration of tomatoes of the control group was 40 days. At a dose of 1.0 kGy was an increase of 15 days compared to control fruits. When applying the dose of 1.5 kGy, the lifetime of the fruit was 70 days and at the dose of 2.0 kGy fruits were of 106 days starting from the initial date of experiment. The third and final batch,the lifetime of the fruits were not higher than those found in previous batches, the control group had a permanence of 14 days. At the dose of 1.0 kGy, there was the additional 10 days compared to the control group. At a dose of 1.5 kGy was observed that the fruits lasted 35 days starting from the initial day of the experiment and the tomatoes that were irradiated at 2.0 kGy the duration was 45 days from the start date of the

  11. Transfer of Cobalt-60 to plants from soils treated with sewage sludge

    International Nuclear Information System (INIS)

    Grummitt, W.E.

    1976-01-01

    The uptake of 60 Co from soils fertilized with contaminated sewage sludge has been investigated under a variety of experimental conditions. A number of garden plots were prepared by thoroughly mixing sludge containing 60 Co with farm soils from the Ottawa Valley. Edible plants were grown in the open on these plots under conditions approximating those in market gardens. The crops were harvested at maturity and were prepared for measurement of 60 Co by drying portions of the roots, leaves, stems and fruit. The samples were counted on a large germanium detector which was capable of resolving 60 Co from other gamma-emitting nuclides. Cobalt was readily taken up from contaminated sludge but was nonuniformly distributed in various parts of the plant. In general, the roots showed the highest levels while edible portions such as seeds and tubers had much lower concentrations. The uptake ratio, expressed as radioactivity in the sample to radioactivity in the soil, varied from 0.003 to 8 on a dry-weight basis. (author)

  12. Effect of the gamma radiation of cobalt 60 on the beta carotids present in the carrot

    International Nuclear Information System (INIS)

    Perez Lopez, Sergio Victor Hugo

    1997-01-01

    In the present work it was investigated the effect of the gamma radiation of cobalt 60 on the beta carotid's in the carrot (daucus carota), using for it three different radiation dose (100, 150 and 200 kilo-rad) and analyzing them by means of the liquid chromatography technique of high resolution (HPLC)

  13. Spontaneous carotid-cavernous sinus fistula disappeared following cobalt 60 irradiation. Case report

    Energy Technology Data Exchange (ETDEWEB)

    Satoh, Toru; Yamamoto, Yuji; Asari, Syoji (Matsuyama Shimin Hospital, Ehime (Japan))

    1983-12-01

    The authors reported a case of spontaneous carotid-cavernous sinus fistula fed by meningohypophyseal trunk of the internal carotid artery, that completely disappeared following cobalt 60 irradiation to the region of fistula (27 days; total dose, 4,100 rad). A 65-year-old man was admitted to our hospital on May 25, 1982, with a two-week history of progressive prominence of the left eye, diplopia on left lateral gaze, and continuous intracranial bruit. He first noted redness of the left eye without apparent cause such as head trauma. On admission, slight nonpulsative exophthalmos, periorbital edema, chemosis, and venous congestion of the conjunctiva of the left eye were noted. The pupils were reactive and equal in size, and the left abducent nerve palsy was observed. Fundoscopic examination disclosed to be normal. No bruit was heard over the left orbital region. Left carotid angiography on May 28 demonstrated dural internal carotid-cavernous sinus fistula fed by meningohypophyseal trunk, and drained into superior and inferior ophthalmic veins and basilar venous plexus. Though the patient was treated only conservatively, symptoms became worse to decrease visual acuity. On July 14, we started cobalt 60 irradiation to the region of fistula (27 days; total dose 4,100 rad). Symptoms gradually improved about halfway through irradiation. After completion of irradiation, almost complete improvement of visual and ocular symptoms was observed except the left abducent nerve palsy. Repeated angiography on Aug. 20 revealed complete disappearance of fistula. Three months after treatment, no recurrence of symptoms was observed and the abducent nerve palsy persisted without improvement.

  14. Experimental investigation of cobalt-60 accumulation and elimination in Cyprinus carpio (L.)

    International Nuclear Information System (INIS)

    Fritsch, A.F.

    1985-11-01

    When introduced in cation form, 60 Co showed a distinct tendency to form anion or neutral complexes (50% and 20%, respectively); this was favorized by a high biomass content per liter of water. The ionic evolution of the radionuclide did not affect its accumulation level in the fish. Direct contamination predominated (70%) and the concentration factor at equilibrium was 10. Nutritional transfer from Limnaea to carp, after ingestion of 45 contaminated rations in 63 days, resulted in a low radionuclide retention factor (3 x 10 -3 ) that was not subject to bioamplification. Cobalt-60 was primarily eliminated via urine (60%), while the fecal matter contained only 20% of the radioactive isotope ingested in the food. The 60 Co content of carp contaminated from the water increased proportionally with the temperature. However, the 60 Co concentration did not vary significantly with the thermal factor, and the radionuclide concentration factor ranged from 4 to 6 between 8 0 C and 25 0 C. Decontamination was generally a two-phase process characterized by a short biological half-life ( 60 Co contained in the fish. The high 60 Co content of the digestive tract may be explained by fecal excretion of the radioactive isotope (30-40% of the elimination). The kidneys act as radionuclide elimination regulators via the urinary system [fr

  15. Estimation of cobalt release from feed water heater tubes of BWRs

    International Nuclear Information System (INIS)

    Uchida, S.; Kitamura, M.; Ozawa, Y.

    1983-01-01

    To evaluate the release source of cobalt from heater tubes of the feed water line, release rate measurements were carried out by detecting 60 Co released from irradiated stainless steel in contact with neutral water at an oxygen concentration of 20 ppb. The dependences of cobalt release rate on temperature, flow velocity and exposure time were studied after 670 hours of release experiments, and an empirical equation (which is presented) was obtained in the temperature range from 150 to 240 deg C. A decrease in the cobalt release rate above 250 deg C was considered due to the formation of a protective oxide layer. From these data, the amount of cobalt released from individual feed water heaters was evaluated. It was demonstrated that low cobalt containing stainless steel was economically applied only in the higher temperature region of the heater (20% of the total surface) to reduce cobalt feed rate into the reactor (to approx. 1/2). (author)

  16. An athymic mouse model to mimic cobalt-60 cutaneous radiation injury

    Energy Technology Data Exchange (ETDEWEB)

    Mosca, Rodrigo Crespo; Ferreira, Danilo Cardenuto; Napolitano, Celia Marina; Santin, Stefany Plumeri; Dornelles, Leonardo Dalla Porta; Alvarenga, Eluara Ortigoso; Mathor, Monica Beatriz, E-mail: rcmosca@usp.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2013-07-01

    Propose: Cutaneous wound from irradiation is the most common complication in radiotherapy treatment, and can be lead to mortality. We describe an athymic mouse model to mimic cutaneous radiation injury by Cobalt-60. Methods: A protocol was including dosimetry with silicon diodes,10x10x5 cm arrangement made by four lead bricks and PVC pipe designed to immobilize the athymic mouse in order to irradiate one clamped back skin point that was subdivided in four parts. To get the measurements of dose rates on the arrangement in Panoramic Irradiator, it was used a silicon diode encased in an opaque protection for ambient light and connected to an electric cable, forming a dosing probe. The currents generated in diode sensitive volume as a function of time of exposure to gamma radiation coming from the radiator, with dose rate of 0,015 Gy/min in positions 1, 0,021 Gy/min in position 2, 0,55 Gy/min in position 3 and 1,45 Gy/min in position four. After the dosimetry, each athymic mouse was anesthetized using Xylazine and Ketamine dilution and entered into a PVC pipe and a small portion of skin (1 cm{sup 3}) was clamped. This tube was then fixed to arrangement and the athymic mouse was irradiate for 60 min, than it was being returned to its cage. Results: The wound was visualized in all animals and photographed after 5 days of irradiation, with the emergence of ulceration after 9 days. No systemic or lethal sequelae occurred or visualized in any animals. Late clinical signs included a wound healing after 22 days. Conclusion: While still being a baseline study, we created a new functional preclinical animal model that can be used for new therapies and may improve radiotherapy management. (author)

  17. An athymic mouse model to mimic cobalt-60 cutaneous radiation injury

    International Nuclear Information System (INIS)

    Mosca, Rodrigo Crespo; Ferreira, Danilo Cardenuto; Napolitano, Celia Marina; Santin, Stefany Plumeri; Dornelles, Leonardo Dalla Porta; Alvarenga, Eluara Ortigoso; Mathor, Monica Beatriz

    2013-01-01

    Propose: Cutaneous wound from irradiation is the most common complication in radiotherapy treatment, and can be lead to mortality. We describe an athymic mouse model to mimic cutaneous radiation injury by Cobalt-60. Methods: A protocol was including dosimetry with silicon diodes,10x10x5 cm arrangement made by four lead bricks and PVC pipe designed to immobilize the athymic mouse in order to irradiate one clamped back skin point that was subdivided in four parts. To get the measurements of dose rates on the arrangement in Panoramic Irradiator, it was used a silicon diode encased in an opaque protection for ambient light and connected to an electric cable, forming a dosing probe. The currents generated in diode sensitive volume as a function of time of exposure to gamma radiation coming from the radiator, with dose rate of 0,015 Gy/min in positions 1, 0,021 Gy/min in position 2, 0,55 Gy/min in position 3 and 1,45 Gy/min in position four. After the dosimetry, each athymic mouse was anesthetized using Xylazine and Ketamine dilution and entered into a PVC pipe and a small portion of skin (1 cm 3 ) was clamped. This tube was then fixed to arrangement and the athymic mouse was irradiate for 60 min, than it was being returned to its cage. Results: The wound was visualized in all animals and photographed after 5 days of irradiation, with the emergence of ulceration after 9 days. No systemic or lethal sequelae occurred or visualized in any animals. Late clinical signs included a wound healing after 22 days. Conclusion: While still being a baseline study, we created a new functional preclinical animal model that can be used for new therapies and may improve radiotherapy management. (author)

  18. Accumulation of cobalt by cephalopods

    International Nuclear Information System (INIS)

    Nakahara, Motokazu

    1981-01-01

    Accumulation of cobalt by cephalopod mollusca was investigated by radiotracer experiments and elemental analysis. In the radiotracer experiments, Octopus vulgaris took up cobalt-60 from seawater fairly well and the concentration of the nuclide in whole body attained about 150 times the level of seawater at 25th day at 20 0 C. Among the tissues and organs measured, branchial heart which is the specific organ of cephalopods showed the highest affinity for the nuclide. The organ accumulated about 50% of the radioactivity in whole body in spite of its little mass as 0.2% of total body weight. On the other hand, more than 90% of the radioactivity taken up from food (soft parts of Gomphina melanaegis labelled with cobalt-60 previously in an aquarium) was accumulated in liver at 3rd day after the single administration and then the radioactivity in the liver seemed to be distributed to other organs and tissues. The characteristic elution profiles of cobalt-60 was observed for each of the organs and tissues in Sephadex gel-filtration experiment. It was confirmed by the gel-filtration that most of cobalt-60 in the branchial heart was combined with the constituents of low molecular weights. The average concentration of stable cobalt in muscle of several species of cephalopods was 5.3 +- 3.0 μg/kg wet and it was almost comparable to the fish muscle. On the basis of soft parts, concentration of the nuclide closed association among bivalve, gastropod and cephalopod except squid that gave lower values than the others. (author)

  19. 40 CFR 421.316 - Pretreatment standards for new sources.

    Science.gov (United States)

    2010-07-01

    ... GUIDELINES AND STANDARDS NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY Secondary Tungsten and Cobalt... 87.800 (k) Cobalt hydroxide filter cake wash. PSNS for the Secondary Tungsten and Cobalt Subcategory...

  20. Cobalt-60 gamma radiation effects on degradation of pesticides used in stored rice and beans

    International Nuclear Information System (INIS)

    Groppo, Gerson A.

    1988-02-01

    The present work, carried out at CENA, an agriculture nuclear energy center - University of Sao Paulo - Brazil, investigates the Cobalt-60 gamma radiation effects on insecticides applied to stored rice and beans. The radiation dose applied - 200 Gy - to the stored rice and beans treated with insecticides was not sufficient to cause a noticeable chemical degradation through insect mortality. (author). 31 refs., 23 tabs

  1. Re-Shielding of Cobalt-60 Teletherapy Rooms for Tomotherapy and Conventional Linear Accelerators using Monte Carlo Simulations

    Science.gov (United States)

    Çeçen, Yiğit; Yazgan, Çağrı

    2017-09-01

    Purpose. Nearly all Cobalt-60 teletherapy machines were removed around the world during the last two decades. The remaining ones are being used for experimental purposes. However, the rooms of these teletherapy machines are valuable because of lack of space in radiotherapy clinics. In order to place a new technology treatment machine in one of these rooms, one should re-shield the room since it was designed only for 1.25 MeV gamma beams on average. Mostly, the vendor of the new machine constructs the new shielding of the room using their experience. However, every radiotherapy room has different surrounding work areas and it would be wise to shield the room considering these special conditions. Also, the shield design goal of the clinic may be much lower than the International Atomic Energy Agency (IAEA) or the local association accepts. The study shows re-shielding of a Cobalt-60 room, specific to the clinic, using Monte Carlo simulations. Materials & Methods: First, a 6 MV Tomotherapy machine, then a 10 MV conventional linear accelerator (LINAC) was placed inside the Cobalt-60 teletherapy room. The photon flux outside the room was simulated using Monte Carlo N-Particle (MCNP6.1) code before and after re-shielding. For the Tomotherapy simulation, flux distributions around the machine were obtained from the vendor and implemented as the source of the model. The LINAC model was more generic with the 10 MeV electron source, the tungsten target, first and secondary collimators. The aim of the model was to obtain the maximum (40x40 cm2) open field at the isocenter. Two different simulations were carried out for gantry angles 90o and 270o. The LINAC was placed in the room such that the primary walls were A' (Gantry 270o) and C' (Gantry 90o) (figure 1). The second part of the study was to model the re-shielding of the room for Tomotherapy and for the conventional LINAC, separately. The aim was to investigate the recommended shielding by the vendors. Left side of the room

  2. Differential gene expression in primary fibroblasts induced by proton and cobalt-60 beam irradiation

    DEFF Research Database (Denmark)

    Nielsen, Steffen; Bassler, Niels; Grzanka, Leszek

    2017-01-01

    profile: entrance, mid-SOBP and at the SOBP distal edge. Dose was delivered in three fractions × 3.5 Gy(RBE) (RBE 1.1). Cobalt-60 (Co-60) irradiation was used as reference. Real-time qPCR was performed to determine gene expression levels for 17 genes associated with inflammation response, fibrosis...... and angiogenesis. RESULTS: Differences in median gene expression levels were observed for multiple genes such as IL6, IL8 and CXCL12. Median IL6 expression was 30%, 24% and 47% lower in entrance, mid-SOBP and SOBP distal edge groups than in Co-60 irradiated cells. No genes were found to be oppositely regulated...... fibroblast cultures. Inflammatory factors were generally less extensively upregulated by proton irradiation compared with Co-60 photon irradiation. These effects may possibly influence the development of normal tissue damage in patients treated with proton beam therapy....

  3. REVISS cobalt-60 production in Russia and beyond

    Science.gov (United States)

    Coppell, David; Latham, Ian; Nazarov, Michael

    2004-09-01

    Since Russian English Venture in Isotope Supply and Services (REVISS) Services is one of only two major global suppliers of sealed radiation sources to the industrial sterilization industry, security of supply of raw materials is understandably of primary concern to the users in the market place. This paper outlines the history, facilities and production capability of REVISS isotope suppliers, from MAYAK Production Association and Leningrad Nuclear Power Plant in Russia to Commission Nacional Energia Atomica in Argentina. The paper provides technical details of reactors and handling facilities used for fabrication of 60Co and 137Cs sources for industrial and research gamma irradiators and other applications. Other sources of 60Co in the world today will be reviewed briefly.

  4. Immunological assessment of mice hyperimmunized with native and Cobalt-60-irradiated Bothrops venoms

    International Nuclear Information System (INIS)

    Ferreira Junior, R.S.; Meira, D.A.; Martinez, J.C.

    2005-01-01

    ELISA was used to evaluate, accompany, and compare the humoral immune response of Swiss mice during hyperimmunization with native and Cobalt-60-irradiated ( 60 Co) venoms of Bothrops jararaca, Bothrops jararacussu and Bothrops moojeni. Potency and neutralization were evaluated by in vitro challenges. After hyperimmunization, immunity was observed by in vivo challenge, and the side effects were assessed. The animals immunization with one LD50 of each venom occurred on days 1, 15, 21, 30, and 45, when blood samples were collected; challenges happened on the 60th day. Results showed that ELISA was efficient in evaluating, accompanying and comparing mouse immune response during hyperimmunization. Serum titers produced with natural venom were similar to those produced with irradiated venom. Immunogenic capacity was maintained after 60 Co-irradiation. The sera produced with native venom showed neutralizing potency and capacity similar to those of the sera produced with irradiated venom. All antibodies were able to neutralize five LD50 from these venoms. Clinical alterations were minimum during hyperimmunization with irradiated venom, however, necrosis and death occurred in animals inoculated with native venom. (author)

  5. Evaluation of cobalt-60 energy deposit in mouse and monkey using Monte Carlo simulation

    Energy Technology Data Exchange (ETDEWEB)

    Woo, Sang Keun; Kim, Wook; Park, Yong Sung; Kang, Joo Hyun; Lee, Yong Jin [Korea Institute of Radiological and Medical Sciences, KIRAMS, Seoul (Korea, Republic of); Cho, Doo Wan; Lee, Hong Soo; Han, Su Cheol [Jeonbuk Department of Inhalation Research, Korea Institute of toxicology, KRICT, Jeongeup (Korea, Republic of)

    2016-12-15

    These absorbed dose can calculated using the Monte Carlo transport code MCNP (Monte Carlo N-particle transport code). Internal radiotherapy absorbed dose was calculated using conventional software, such as OLINDA/EXM or Monte Carlo simulation. However, the OLINDA/EXM does not calculate individual absorbed dose and non-standard organ, such as tumor. While the Monte Carlo simulation can calculated non-standard organ and specific absorbed dose using individual CT image. External radiotherapy, absorbed dose can calculated by specific absorbed energy in specific organs using Monte Carlo simulation. The specific absorbed energy in each organ was difference between species or even if the same species. Since they have difference organ sizes, position, and density of organs. The aim of this study was to individually evaluated cobalt-60 energy deposit in mouse and monkey using Monte Carlo simulation. We evaluation of cobalt-60 energy deposit in mouse and monkey using Monte Carlo simulation. The absorbed energy in each organ compared with mouse heart was 54.6 fold higher than monkey absorbed energy in heart. Likewise lung was 88.4, liver was 16.0, urinary bladder was 29.4 fold higher than monkey. It means that the distance of each organs and organ mass was effects of the absorbed energy. This result may help to can calculated absorbed dose and more accuracy plan for external radiation beam therapy and internal radiotherapy.

  6. Evaluation of cobalt-60 energy deposit in mouse and monkey using Monte Carlo simulation

    International Nuclear Information System (INIS)

    Woo, Sang Keun; Kim, Wook; Park, Yong Sung; Kang, Joo Hyun; Lee, Yong Jin; Cho, Doo Wan; Lee, Hong Soo; Han, Su Cheol

    2016-01-01

    These absorbed dose can calculated using the Monte Carlo transport code MCNP (Monte Carlo N-particle transport code). Internal radiotherapy absorbed dose was calculated using conventional software, such as OLINDA/EXM or Monte Carlo simulation. However, the OLINDA/EXM does not calculate individual absorbed dose and non-standard organ, such as tumor. While the Monte Carlo simulation can calculated non-standard organ and specific absorbed dose using individual CT image. External radiotherapy, absorbed dose can calculated by specific absorbed energy in specific organs using Monte Carlo simulation. The specific absorbed energy in each organ was difference between species or even if the same species. Since they have difference organ sizes, position, and density of organs. The aim of this study was to individually evaluated cobalt-60 energy deposit in mouse and monkey using Monte Carlo simulation. We evaluation of cobalt-60 energy deposit in mouse and monkey using Monte Carlo simulation. The absorbed energy in each organ compared with mouse heart was 54.6 fold higher than monkey absorbed energy in heart. Likewise lung was 88.4, liver was 16.0, urinary bladder was 29.4 fold higher than monkey. It means that the distance of each organs and organ mass was effects of the absorbed energy. This result may help to can calculated absorbed dose and more accuracy plan for external radiation beam therapy and internal radiotherapy.

  7. Analysis of radioactive cobalt

    International Nuclear Information System (INIS)

    1977-01-01

    This is a manual published by Science and Technology Agency, Japan, which prescribes on the analysis method for radioactive cobalt which is a typical indexing nuclide among the radioactive nuclides released from nuclear facilities. Since the released cobalt is mainly discharged to coastal region together with waste water, this manual is written for samples of sea water, sea bottom sediments and marine organisms. Radioactive cobalt includes the nuclides of 57 co, 58 Co, 60 Co, etc., the manual deals with them as a whole as 60 Co of long half life. Though 60 Co analysis has become feasible comparatively simply due to scintillation or semi-conductor spectrometry, trace 60 Co analysis is performed quantitatively by co-precipitation or collection into alumina and scintillation spectrometry. However, specific collecting operation and γ-γ coincidence measurement have been required so far. This manual employs 60 Co collection by means of ion-exchange method and measurement with low background GM counting system, to analyze quantitatively and rapidly low level 60 Co. It is primarily established as the standard analyzing method for the survey by local autonomous bodies. It is divided into 4 chapters including introduction sea water, marine organisms, and sea bottom sediments. List of required reagents is added in appendix. (Wakatsuki, Y.)

  8. On the application of a simple model of cobalt-60 beams

    International Nuclear Information System (INIS)

    Gantchew, M.G.

    1979-01-01

    The simple mathematical model of the dose distribution in a phantom irradiated by a single beam of cobalt-60 gamma rays (Wilks, R.J., and Sutcliffe, J.F., 1977, Phys. Med. Biol., vol. 22, 737) requires measurements for each particular field size and diaphragm setting to describe the decrement functions (dose distributions along a straight line perpendicular to the central ray). Measurements made with a Gammatron-3 have shown satisfactory agreement between computed and measured lateral dose distributions for different diaphragm settings if the experimental data was first subjected to additional processing, and Wilks and Sutcliffe's model can therefore be applied to any diaphragm setting using this modification. Field sizes can therefore be entered according to diaphragm indicator reading in dose planning. (U.K.)

  9. High accumulation of cobalt-60 by the particular organ or part of some species in mollusca

    International Nuclear Information System (INIS)

    Yoshida, Katsuhiko

    1981-01-01

    A large amounts of samples in marine Cephalopoda and Tridacna were sampled in north west pacific ocean, near Japan. The samples were separated into organs or parts for determination of Co-60 concentration. A peculiar accumulation of Co-60 by the branchial heart of Octopus was also recognized in field condition, but it had become apparent that branchial heart of squid had not same ability. Liver of Cephalopoda had the ability to highly accumulate the Co-60 and specific activity of squid was one order highter than Octopus. The concentration of Cobalt-60 in visceral muss kidney of Tridacna maxima lineally increased with increasing shell length but that in other soft parts was kept constant. After examination of the other papers it was assumed that Co-60 highly accumulated in these organs was transfered by the food chain. (author)

  10. The Role of External Inputs and Internal Cycling in Shaping the Global Ocean Cobalt Distribution: Insights From the First Cobalt Biogeochemical Model

    Science.gov (United States)

    Tagliabue, Alessandro; Hawco, Nicholas J.; Bundy, Randelle M.; Landing, William M.; Milne, Angela; Morton, Peter L.; Saito, Mak A.

    2018-04-01

    Cobalt is an important micronutrient for ocean microbes as it is present in vitamin B12 and is a co-factor in various metalloenzymes that catalyze cellular processes. Moreover, when seawater availability of cobalt is compared to biological demands, cobalt emerges as being depleted in seawater, pointing to a potentially important limiting role. To properly account for the potential biological role for cobalt, there is therefore a need to understand the processes driving the biogeochemical cycling of cobalt and, in particular, the balance between external inputs and internal cycling. To do so, we developed the first cobalt model within a state-of-the-art three-dimensional global ocean biogeochemical model. Overall, our model does a good job in reproducing measurements with a correlation coefficient of >0.7 in the surface and >0.5 at depth. We find that continental margins are the dominant source of cobalt, with a crucial role played by supply under low bottom-water oxygen conditions. The basin-scale distribution of cobalt supplied from margins is facilitated by the activity of manganese-oxidizing bacteria being suppressed under low oxygen and low temperatures, which extends the residence time of cobalt. Overall, we find a residence time of 7 and 250 years in the upper 250 m and global ocean, respectively. Importantly, we find that the dominant internal resupply process switches from regeneration and recycling of particulate cobalt to dissolution of scavenged cobalt between the upper ocean and the ocean interior. Our model highlights key regions of the ocean where biological activity may be most sensitive to cobalt availability.

  11. The use of radioactive sources for the study of wear in refractory linings

    International Nuclear Information System (INIS)

    Courtois, G.; Hours, R.

    1960-01-01

    Following a discussion on the radioactive method for studying wear in refractory linings (description of the method, advantages and disadvantages, choice of radioactive indicator and detection), the article deals in some detail with the problems of safety involved in this technique. The two most important points discussed are: 1- the need to fix an upper limit of activity in the cast iron: the authors propose a figure of 1 mc of cobalt 60 in 500 tons; 2- the precautions necessary to remedy the diffusion of cobalt 60 in the brickwork (development of special pyro-ceramic sources). After a discussion on the international view point regarding the use of the method, a brief outline of some French projects is given, with particular reference to the case of a blast furnace. A note from the Commission interministerielle des Radioelements is given as an appendix; this deals with special conditions laid down for the use of radioelements in the determination of wear in refractory walls. (author) [fr

  12. Main aspects in licensing of a type B(U) package design for the transport of 12.95 PBq of cobalt 60

    International Nuclear Information System (INIS)

    Lopez Vietri, J.R.; Novo, R.G.; Bianchi, A.J.

    1995-01-01

    This paper points out the relevant technical issues related to the licensing process, of a type B(U) package design, with cylindrical form and 9.3 ton mass, approved by the Argentine Competent Authority for the transport of 12.95 PBq of cobalt 60 as special form radioactive material. It is briefly described the heat transfer analysis, the structural performance under impulsive loads and the shielding calculation under both normal and accidental conditions of transport, as well as the comparative analysis of the results obtained from design, pre-operational tests and independent evaluation performed by the Argentine Competent Authority to verify the compliance with the Regulations for the Safe Transport of Radioactive Material of the International Atomic Energy Agency. (author). 14 refs., 1 fig., tabs

  13. Chronic cardiac arrhythmias produced by focused cobalt-60 gamma irradiation of the canine atria

    International Nuclear Information System (INIS)

    Dick, H.L.H.; Saylor, C.B.; Reeves, M.M.; Davies, M.J.

    1979-01-01

    Cardiac arrhythmias following exposure of the human heart to ionizing radiation have been reported. Earlier experiments involving irradiation of the hearts of various animals failed to consistently produce similar arrhythmias. In the present work, cobalt-60 irradiation was focused on the interatrial septum of the hearts of 12 dogs. Ten animals developed arrhythmias: These were repetive junctional and atrial tachycardias, repetitive atrial fibrillation, and type one, second-degree atrial ventricular block. The duration varied from 1 to 52 days, with onsets varying from 48 to 146 days postirradiation

  14. Production of sealed sources

    International Nuclear Information System (INIS)

    Bandi, L.N.

    2016-01-01

    Radioisotope production has been an ongoing activity in India since the sixties. Radioisotopes find wide-ranging applications in various fields, including industry, research, agriculture and medicine. Board of Radiation and Isotope Technology, an industrial unit of Department of Atomic Energy is involved in fabrication and supply of wide variety of sealed sources. The main radioisotopes fabricated and supplied by BRIT are Cobalt-60, Iridium-192. These isotopes are employed in industrial and laboratory irradiators, teletherapy machines, radiography exposure devices, nucleonic gauges. The source fabrication facilities of BRIT are located at Rajasthan Atomic Power Project Cobalt-60 Facility (RAPPCOF), Kota, Radiological Laboratories Group (RLG) and High Intensity Radiation Utilization Project (HIRUP) at Trombay

  15. Reconstruction of Co-60 Irradiation Facility No.1

    International Nuclear Information System (INIS)

    Nakamura, Yoshiteru; Takada, Isao; Kaneko, Hirohisa; Hirao, Toshio; Haneda, Noriyuki; Mitomo, Shouichi; Tachibana, Hiroyuki; Yoshida, Kenzou

    1989-01-01

    Cobalt Irradiation Facility No.1 was constructed in 1964 as the first large scale Co-60 irradiation facility equipped a deep water pool for source storage of Co-60 sources. Recently, the reconstruction of the facility was decided because the aging of various parts of the facility became remarkable and new research programs required upgradings of the facility. Important points of upgradings are as follows: A shielding capacity of the source storage and pool is increased to 55.5 PBq from 18.5 PBq. The opening in a floor of the irradiation room which is used for the source lifting in the room, is enlarged in order to utilize a large and high intensity source. Radiation resistance of the irradiation apparatus and installed equipments in the radiation room is increased for a high dose rate irradiation. Basic structure and shape of the facility building such as shielding, pool and building roof is not changed but electrical, mechanical equipments and systems are completely renewed. To increase a reliability, the irradiation apparatus and systems are also replaced with an improved and up-to-date one designed based on operation experiences of Co-60 facilities at TRCRE through many years. In addition, auxiliary equipments such as radiation monitors, manipulators, water treatment system and so on are replaced. This report presents the reconstruction of Co-60 Irradiation Facility No.1 stressing on the replacement and modification of the irradiation apparatus. (author)

  16. Effects of gamma radiation of Cobalt-60 on different phases of the evolutive cycle of pinworm - Tuta absoluta (Meyrich, 1917) (Lepidoptera,Gelechiidae)

    International Nuclear Information System (INIS)

    Groppo, Gerson Antonio

    1996-10-01

    The effects of different gamma radiation (Cobalt-60) doses on different phases of the evolutive cycle of Tuta absoluta (Meyrich, 1917) (Lepidoptera, Gelechiidae) have been studied under laboratory conditions in the laboratory of Entomology of Center for Nuclear Energy in Agriculture (CENA), University of Sao Paulo, Piracicaba, Sao Paulo State, Brazil. For all the treatments with gamma radiation a Cobalt-60 source type Gamma beam-650 was used. The doses utilized ranged from of 0,0 (Control) to 3250 Gy with a dose rate of 1110 Gy/h. The experiment was conducted under controlled conditions at 25± 2 deg C, 70 ± 5% of relative humidity and photo period of (12:12). It was verified that the lethal doses were: for eggs - 70 Gy; for larvae - 200 Gy e for pupae - 300 Gy. The sterilizing dose for adults from irradiated larvae was 45 Gy. The sterilizing dose for the crossing of irradiated female with normal males (FI X MN) was 100 Gy and for normal female with irradiated male (FN x MI) was 150 Gy, in the both crosses, doses refer to irradiation of pupae. The sterilizing dose for adults, of both sexes, irradiated and crossed with normal adults, (FI x MN) and (FN x MI, were 150 and 200 Gy, respectively. The average longevity of adults, of both sexes, irradiated and crossed with normal adults was 8,3 days. The immediate lethal dose for adults was 3250 Gy. (author)

  17. 21 CFR 640.60 - Source Plasma.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 7 2010-04-01 2010-04-01 false Source Plasma. 640.60 Section 640.60 Food and... ADDITIONAL STANDARDS FOR HUMAN BLOOD AND BLOOD PRODUCTS Source Plasma § 640.60 Source Plasma. The proper name of the product shall be Source Plasma. The product is defined as the fluid portion of human blood...

  18. Characterization of naturally occurring radioactive materials and Cobald-60 contaminated ferrous scraps from steel industries

    International Nuclear Information System (INIS)

    Chao, H.E.; Chiu, H.S.; Hunga, J.Y.; His, H.W.; Chen, Y.B.

    2002-01-01

    Since the occurrence of radioactively contaminated rebar incident in 1992, steel industries in Taiwan were encouraged by Atomic Energy Council (AEC) to install portal monitor to detect the abnormal radiation in shipments of metal scrap feed. From 1994 through 1999, there were 53 discoveries of radioactivity in ferrous scraps by steel companies. These include 15 orphan radioactive sources, 16 cobalt-60 contaminated rebars, 20 Naturally Occurring Radioactive Material (NORM) contaminated scraps, and two unknowns. Most NORM-contaminated scraps were from abroad. The NORM and cobalt-60 contaminated scraps were taken from the steel mills and analyzed in laboratory. The analytical results of scales and sludge sampled from NORM-contaminated scraps combining with the circumstantial evidences indicate that five possible industrial processes may be involved. They are oil production and treatment, heavy mineral sand benefication and rare earth processing, copper mining and processing, recovery of ammonium chloride by lime adsorption in Ammonium-soda process, and tailing of uranium enrichment process. The cobalt-60 activity and trace elements concentrations of contaminated rebars confirm that all of them were produced domestically in the period from Oct. 1982 to Jan. 1983, when the cobalt-60 sources were lost and entered the electric arc furnace to produce the contaminated rebars. (author)

  19. Feasibility study of 24-month cycle using enriched Gadolinium as burnable poison for OPR1000

    Energy Technology Data Exchange (ETDEWEB)

    Moon, Sang-Rae; Shin, Ho-Cheol [KHNP Central Research Institute, Daejeon (Korea, Republic of)

    2016-10-15

    All of cobalt-60 sources are imported to Korea. CANDU units are generally used to produce cobalt-60 at Bruce and Point Lepreau in Canada and Embalse in Argentina. China has started production of cobalt-60 using its CANDU 6 Qinshan Phase III nuclear power plant in 2009. For cobalt-60 production, the reactor's full complement of stainless steel adjusters is replaced with neutronically equivalent cobalt-59 adjusters, which are essentially invisible to reactor operation. With its very high neutron flux and optimized fuel burn-up, the CANDU has a very high cobalt-60 production rate in a relatively short time. This makes CANDU an excellent vehicle for bulk cobalt-60 production. Several studies have been performed to produce cobalt-60 using adjuster rod at Wolsong nuclear power plant. This study proposed new concept for producing cobalt-60 and performed the feasibility study. Bundle typed cobalt loading concept is proposed and evaluated the feasibility to fuel management without physics and system design change. The requirement to load cobalt bundle to the core was considered and several channels are nominated. The production of cobalt-60 source is very depend on the flux level and burnup directly.

  20. OH masers associated with IRAS point sources

    NARCIS (Netherlands)

    Masheder, MRW; Cohen, RJ; Martin-Hernandez, NL; Migenes,; Reid, MJ

    2002-01-01

    We report a search for masers from the Lambda-doublet of the ground-state of OH at 18cm, carried out with the Jodrell Bank Lovell Telescope and with the 25m Dwingeloo telescope. All objects north of delta = -20degrees which appear in the IRAS Point Source Catalog with fluxes > 1000 Jy at 60mum and

  1. Study to use graded cobalt adjuster in 540 MWe PHWR

    International Nuclear Information System (INIS)

    Raj, Manish; Fernando, M.P.S.; Pradhan, A.S.; Kumar, A.N.

    2007-01-01

    Full text: There are 17 adjusters in 540 MWe PHWR, which are essentially provided for xenon override function. They also provide flux flattening being in the central region of the reactor core. The present design of adjusters consists of stainless steel tube. The adjuster rods are grouped into 8 banks for movement. Since adjusters are normally fully inserted during reactor operation, they are best suited for production of cobalt 60. The nickel-plated cobalt in the form of either slugs or pellet are used for the design of cobalt pencils. The number of pencils can be varied to optimize the reactivity load and cobalt 60 production requirement. The worth and activity of cobalt adjusters have been worked out considering different pin configuration for the adjuster assembly. To start with we have assumed all adjusters throughout its length are of the same configuration. The flux depression factors within the cobalt pencils have been considered in the estimations of the specific and total cobalt 60 activities. The option of using graded cobalt adjusters, where different pin configuration along the length is considered for better flux flattening

  2. Radiation incidents with a cobalt-60 teletherapy unit

    Energy Technology Data Exchange (ETDEWEB)

    Lane, R G; Tolbert, D D; Pailwal, B R; Radtke, R R [Wisconsin Univ., Madison (USA). Dept. of Radiology

    1976-08-01

    Three radiation incidents associated with source drive failures on one particular /sup 60/Co teletherapy unit, which took place during a single year's operation, are discussed. In each case the extra treatment time of the patient, the exposure to the technician, the cause of the breakdown and the subsequent action taken are detailed. Recommendations for users of /sup 60/Co teletherapy units to minimise the results of the malfunctioning of such a system are given.

  3. Radiation incidents with a cobalt-60 teletherapy unit

    International Nuclear Information System (INIS)

    Lane, R.G.; Tolbert, D.D.; Pailwal, B.R.; Radtke, R.R.

    1976-01-01

    Three radiation incidents associated with source drive failures on one particular 60 Co teletherapy unit, which took place during a single year's operation, are discussed. In each case the extra treatment time of the patient, the exposure to the technician, the cause of the breakdown and the subsequent action taken are detailed. Recommendations for users of 60 Co teletherapy units to minimise the results of the malfunctioning of such a system are given. (U.K.)

  4. Hematological changes in sheep inoculated with natural and Cobalt60-irradiated Crotalus durissus terrificus venom (Laurenti, 1768)

    International Nuclear Information System (INIS)

    Netto, D.P.; Alfieri, A.A.; Balarim, M.R.S.; Chiacchio, S.B.; Bicudo, P.L.; Nascimento, N.

    2004-01-01

    Natural (NV) and Cobalt 60 -irradiated (IrV) Crotalus durissus terrificus venom were used to evaluate serum production capacity of sheep and possible hematological and biochemical effects. Freeze-dried venom aliquots were diluted in acidified saline solution (NaCl 150 m M, p H 3.0) and irradiated by a Cobalt 60 source at a dose of 5.54 x 102 Gy/h and a concentration of 2.000 Gy. Twelve sheep were divided into two groups of six animals. One group received irradiated venom (IrV) and the other natural venom (NV). Three antigen doses (venom) were administered at monthly intervals. Blood samples were collected weekly for analysis of serum neutralization potency and capacity, complete blood count, total plasma protein, fibrinogen, albumin, and globulin. At the end of the experiment, the animals were challenged with a LD 50 for sheep and showed no signs of envenoming. The two groups did not present clinical alterations. Results of the total leukocyte count did not present interaction or time factor effect for both groups, but there was a different action between them, with the NV group presenting more cells than the IrV group. The leukocyte increase to 13,000/μl indicates that slight leucocytosis occurred in the week after the first inoculation in the NV group. There was no statistically significant difference between groups in the absolute count of segmented neutrophils, eosinophils, and lymphocytes but there were statistically significant oscillations in values at the different collecting times. The NV group presented an increase in the absolute neutrophil count after the first inoculation that persisted for 5 weeks. In the IrV group, the increase in neutrophils occurred only in the first week returning to normal in the following weeks. The alterations in the neutrophil count are indicative of systemic inflammatory response related to cytokine release; response was more marked in the N V group, showing its greater toxicity. (author)

  5. Journey of a Package: Category 1 Source (Co-60) Shipment with Several Border Crossings, Multiple Modes

    International Nuclear Information System (INIS)

    Gray, P. A.

    2016-01-01

    Radioactive materials (RAM) are used extensively in a vast array of industries and in an even wider breadth of applications on a truly global basis each and every day. Over the past 50 years, these applications and the quantity (activity) of RAM shipped has grown significantly, with the next 50 years expected to show a continuing trend. The movement of these goods occurs in all regions of the world, and must therefore be conducted in a manner which will not adversely impact people or the environment. Industry and regulators have jointly met this challenge, so much so that RAM shipments are amongst the safest of any product. How has this level of performance been achieved? What is involved in shipping RAM from one corner of the world to another, often via a number of in-transit locations and often utilizing multiple modes of transport in any single shipment? This paper reviews one such journey, of Category 1 Cobalt-60 sources, as they move from point of manufacture through to point of use including the detailed and multi-approval process, the stringent regulatory requirements in place, the extensive communications required throughout, and the practical aspects needed to simply offer such a product for sale and transport. Upon completion, the rationale for such an exemplary safety and security record will be readily apparent. (author)

  6. Treatment of radioactive liquid waste (Co-60) by sorption on Zeolite Na-A prepared from Iraqi kaolin

    International Nuclear Information System (INIS)

    Mustafa, Yasmen A.; Zaiter, Maysoon J.

    2011-01-01

    Highlights: ► Iraqi synthetic zeolite type Na-A has been suggested as ion exchange material to treat cobalt-60 in radioactive liquid waste which came from neutron activation for corrosion products. ► The ability of Na-A zeolite to remove cobalt from wastewater was checked for high cobalt concentration (822 mg/L) in addition to low cobalt concentration in the source sample (0.093 mg/L). ► The effects of important design variables on the zeolite column performance were studied these include initial concentration, flow rate, and bed depth. ► The experimental results show that high sorption capacity can be obtained at high influent concentration, low flow rate, and high bed depth. ► Higher column performance was obtained at higher bed depth. - Abstract: Iraqi synthetic zeolite type Na-A has been suggested as ion exchange material to treat cobalt-60 in radioactive liquid waste which came from neutron activation for corrosion products. Batch experiments were conducted to find out the equilibrium isotherm for source sample .The equilibrium isotherm for radioactive cobalt in the source sample showed unfavorable type, while the equilibrium isotherm for the total cobalt (the radioactive and nonradioactive cobalt) in the source sample showed a favorable type. The ability of Na-A zeolite to remove cobalt from wastewater was checked for high cobalt concentration (822 mg/L) in addition to low cobalt concentration in the source sample (0.093 mg/L). A good fitting for the experimental data with Langmuir equilibrium model was observed. Langmuir constant qm which is related to monolayer adsorption capacity for low and high cobalt concentration was determined to be 0.021 and 140 mg/g zeolite . The effects of important design variables on the zeolite column performance were studied these include initial concentration, flow rate, and bed depth. The experimental results have shown that high sorption capacity can be obtained at high influent concentration, low flow rate, and

  7. Radio cobalt in French rivers

    International Nuclear Information System (INIS)

    Lambrechts, A.; Baudin-Jaulent, Y.

    1996-01-01

    The isotopes 58 and 60 of cobalt present in liquid wastes from nuclear plants or from fuel reprocessing plant of Marcoule are fixed in the different compartments of French rivers. The activity levels of radio-cobalt vary according to the sampled compartments nature (bryophyta > immersed plants > sediment > fish). Elsewhere, laboratory experimentations show that the contamination of fish occurs essentially from the water way rather than from food. Cobalt is mainly fixed by kidneys; muscles is no more than 30 % of the total fish activity. (author)

  8. Concrete Shielding For Radiation Safety And Unexpected Dangerous Inside Cobalt-60 Industrial Irradiator

    International Nuclear Information System (INIS)

    Keshk, A.B.; Aly, R.A.

    2011-01-01

    The study shows a proposed destruction inside one of three cobalt-60 industrial irradiators to determine and reduce the negative results, to improve and modify emergency plan to face terrorism works. The results show the performance of concrete shielding (walls and ceiling) contains the bad effect of dynamic pressures. The explosion forces are prevented to destructive by performance of their concrete shielding, which will contain the most components of devastated systems inside each irradiator after explosion. Shield penetration like electrical cable tunnels, pushers holes, hole with removable plug, product boxes openings, lens opening and ozone duct are affected badly by destruction. Through probability of transporting, some of devastated parts of broken radioactive cobalt- 60 pencils from inside radiation concreter room to outside (surrounded environment) are maintained and causing very danger radiation exposure by gamma rays outside irradiator. A necessity needs to modify emergency plan to prevent any explosive materials to enter inside the main building (irradiation sale) and also discovering any explosive materials which are placed inside the product boxes before passing to inside irradiator. The minimizing radiation exposure (2 mrem/h) inside underground radiation shelters are maintained by reducing radiation dose exerted from a nuclear explosion of 20 kT about 1 km away to a safe value, and calculating the protective factors of radiation main building basements are more than 40 (safety factor) as they are located under ground level, are surrounded by sandy soil and are constructed by concrete. The study shows the proposed basements of the main building maintain success to use as under ground safe radiation shelter (during emergency) with separate safe radiation trace. It begins from the main opening of irradiation sale and leads to underground proposed shelter through modified main stair

  9. Quarantine treatment for Sitophilus zeamais (Coleoptera: Curculionidae) through gamma radiation from Cobalt-60

    International Nuclear Information System (INIS)

    Ramos, Amanda Cristina Oliveira; Potenza, Marcos Roberto

    2009-01-01

    Pests like beetles, moths, fungus and mites normally attack stored products such as grains, spices, flours, brans and tobacco in bale. Among these pests the Sitophilus zeamais is one of the most important pests due its elevated potential of reproduction, infesting a great number of products, inducing great damages. This work had as objective to determine the efficacy of gamma radiation from Cobalt-60 as quarantine treatment for S. zeamais. The insects used in this experiment were reared in maize grains, at the Laboratorio de Artropodes of the Instituto Biologico/SP, on climatic room with 27 ± 2 deg C of temperature and relative humidity of 70 ± 5%. Samples containing 25 adult insects were put in acrylic recipients measuring 2.8cm x 2.8cm. Each treatment had four repetitions, in a total of 100 insects for treatment. They were irradiated with growing doses of gamma radiation: 0 (control); 0,25; 0,5; 0,75; 1,0; 1,25; 1,5; 1,75; 2,0; 2,25 2,5; 2,75; 3,0; 3,5 e 4,0 kGy, in a experimental irradiator of Cobalt-60, model Gammacell-220, located at the Centro de Tecnologia da Radiacoes - CTR of the Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN/SP. After irradiation, the samples were transferred to plastic recipients measuring 3,5cm x 10cm, with perforated lids (to allow gaseous exchanges). After the irradiation the samples were kept in climatic room (27 ± 2 deg C and 70 ± 5%). The mortality of insects was evaluated 1 hour after the irradiation and also on the next 7 days. By the results obtained we can conclude that was the dose of 2.75 kGy that induced the immediate mortality for adult insects of the specie S. zeamais. (author)

  10. Dosimetric Consistency of Co-60 Teletherapy Unit- a ten years Study.

    Science.gov (United States)

    Baba, Misba H; Mohib-Ul-Haq, M; Khan, Aijaz A

    2013-01-01

    The goal of the Radiation standards and Dosimetry is to ensure that the output of the Teletherapy Unit is within ±2% of the stated one and the output of the treatment dose calculation methods are within ±5%. In the present paper, we studied the dosimetry of Cobalt-60 (Co-60) Teletherapy unit at Sher-I-Kashmir Institute of Medical Sciences (SKIMS) for last 10 years. Radioactivity is the phenomenon of disintegration of unstable nuclides called radionuclides. Among these radionuclides, Cobalt-60, incorporated in Telecobalt Unit, is commonly used in therapeutic treatment of cancer. Cobalt-60 being unstable decays continuously into Ni-60 with half life of 5.27 years thereby resulting in the decrease in its activity, hence dose rate (output). It is, therefore, mandatory to measure the dose rate of the Cobalt-60 source regularly so that the patient receives the same dose every time as prescribed by the radiation oncologist. The under dosage may lead to unsatisfactory treatment of cancer and over dosage may cause radiation hazards. Our study emphasizes the consistency between actual output and output obtained using decay method. The methodology involved in the present study is the calculations of actual dose rate of Co-60 Teletherapy Unit by two techniques i.e. Source to Surface Distance (SSD) and Source to Axis Distance (SAD), used for the External Beam Radiotherapy, of various cancers, using the standard methods. Thereby, a year wise comparison has been made between average actual dosimetric output (dose rate) and the average expected output values (obtained by using decay method for Co-60.). The present study shows that there is a consistency in the average output (dose rate) obtained by the actual dosimetry values and the expected output values obtained using decay method. The values obtained by actual dosimetry are within ±2% of the expected values. The results thus obtained in a year wise comparison of average output by actual dosimetry done regularly as a part of

  11. Sensory analysis of dairy products irradiated with cobalt-60 at -78 degrees C

    International Nuclear Information System (INIS)

    Hashisaka, A.E.; Einstein, M.A.; Rasco, B.A.; Hungate, F.P.; Dong, F.M.

    1990-01-01

    Sensory evaluations by healthy individuals were conducted on cobalt-60 irradiated retail dairy products which were to be incorporated into the low microbial diets of immunosuppressed patients. Irradiation (40 kGy at -78 degrees C) caused little change in product color or texture, but generally there was a decrease in overall acceptability and an increase in off-flavor and aftertaste. Modified atmosphere packaging (nitrogen, helium, or air) or antioxidant addition (ascorbyl palmitate or a combination of butylated hydroxyanisole and butylated hydroxytoluene) prior to irradiation were effective in preserving specific sensory attributes, which in some cases resulted in improved overall acceptability (helium packed peppermint ice cream; ascorbyl palmitate treated strawberry yogurt bars) when compared to untreated irradiated products

  12. Construction of an apparatus for nuclear orientation measurements at low temperatures. Application to neodymium-cobalt alloy; Realisation d'un appareil pour des mesures d'orientation nucleaire a basse temperature. Application a l'alliage neodyme-cobalt

    Energy Technology Data Exchange (ETDEWEB)

    Mayer, E [Commissariat a l' Energie Atomique, Grenoble (France). Centre d' Etudes Nucleaires

    1965-10-01

    We describe experiments along which has been studied the anisotropy of {gamma} radiations emitted by oriented nuclei. We have used the great hyperfine fields acting on nuclei in ferromagnetic metals so as to produce alignment at low temperature. By irradiation we obtained a few cobalt 60 nuclei in our samples which were then cooled down to 0,01 K. The anisotropic rate of the 1,33 MeV {gamma} radiation was measured in function of the sample temperature, using as thermometer the anisotropy of {gamma} radiation emitted by cobalt 60 nuclei in a cobalt single crystal. Cobalt 60 was lined up in a cobalt nickel alloy (40% Ni). The hyperfine field at the cobalt was measured compared to the effective field in metallic cobalt: Heff(Co Ni)/Heff(Co metal) = 0.71 {+-} 0.12. These results are in good agreement with specific heat measurements made previously. Cobalt 60 has been polarised in a neodymium-cobalt alloy (NdCo{sub 5}). The field at the cobalt in NdCo{sub 5} has been measured compared to the field in metallic cobalt and taking the non-saturation into account we found 165000 oersteds < Heff(NdCo{sub 5}) < 220000 oersteds. (author) [French] Nous decrivons des experiences au cours desquelles nous avons etudie l'anisotropie de rayonnements {gamma} emis par des noyaux orientes. Nous avons utilise les grands champs hyperfins agissant sur las noyaux dans les metaux ferromagnetiques pour produire l'alignement a basse temperature. Par irradiation nous avons obtenu quelques noyaux de cobalt 60 dans nos echantillons qui furent ensuite refroidis a 0,01 K. Le degre d'anisotropie du rayonnement {gamma} de 1,33 MeV fut mesure en fonction de la temperature de l'echantillon en utilisant l'anisotropie du rayonnement {gamma} de noyaux de cobalt 60 dans un monocristal de cobalt metallique utilise comme thermometre. Le cobalt 60 a ete aligne dans un alliage de cobalt-nickel (40% Ni). Le champ hyperfin au niveau du cobalt a ete mesure par rapport au champ effectif dans le cobalt metallique

  13. Study of ozone gas formed in the industrial radiation process with cobalt-60 and its impact on the environment

    International Nuclear Information System (INIS)

    Uzueli, Daniel Henrique

    2013-01-01

    The radiation processing is present in various products such as foods, medical disposable, electrical cables, gems, among others. This process aims to improve the properties, sterilize or sanitize irradiated products. In industrial irradiators facilities, electromagnetic radiation (gamma and X-rays) or electrons before they interact with the products in processing, there are a layer of air. To interact with this air layer, it causes radiolytic effects on the molecules present in the ambient atmosphere, and the main interaction are with the oxygen molecules that have their bonds broken, separating them into two highly reactive atoms that recombine with the other molecule of oxygen to form ozone gas. In this work it was studied the formation, decay and dispersion of ozone in industrial gamma irradiators facilities that use cobalt-60 as a source of radiation. The monitoring of ozone concentration was performed by optical absorption method in a commercial monitor. (author)

  14. Synthesis, analysis and radiolysis of the cobalt III 8 hydroxyquinolinate complex

    International Nuclear Information System (INIS)

    Mestnik, S.A.C.; Silva, C.P.G. da.

    1981-11-01

    The cobalt III 8-hidroxyquinolinate complex was syntetized from a solution of cobalt II. The compound was analysed by IR absorption spectroscopy, elemental analysis and by the determination of number of ligands. The radiolytic degradation was verified by spectrophotometry after submitting samples of 10 - 3 M complex in ethanolic solution to different doses of gamma radiation from a 60 Co source. The change of maximum absorbance of the complex with different doses of gamma radiation and its UV-VIS absorption spectra are presented. The complex in the solid state was also irradiated with 6,9 Mrad of gamma radiation but it didn't present degradation. (Author) [pt

  15. Cobalt accumulation and circulation by blackgum trees

    International Nuclear Information System (INIS)

    Thomas, W.A.

    1975-01-01

    Blackgum (Nyssa sylvatica Marsh.) trees accumulate far greater concentrations of cobalt in mature foliage than do other species on the same site (363 ppM in ash of blackgum, compared with about 3 ppM by mockernut hickory and about 1 ppM by red maple, tulip tree, and white oak). Cobalt concentrations in dormant woody tissues of blackgum also significantly exceed those in the other four species. Inoculation of six blackgums with 60 Co revealed that cobalt remains mobile in the trees for at least 3 years. Foliar concentrations of stable cobalt increase uniformly until senescence. In late August, foliage accounts for only 9 percent of total tree weight but 57 percent of total tree cobalt. Losses of cobalt from trees occur almost entirely by leaf abscission, and the loss rates of weight and cobalt from decomposing litter are similar. Retention of cobalt in the biologically active soil layers perpetuates zones of cobalt concentration created by this species in woodlands

  16. Hematological changes in sheep inoculated with natural and Cobalt{sub 60}-irradiated Crotalus durissus terrificus venom (Laurenti, 1768)

    Energy Technology Data Exchange (ETDEWEB)

    Netto, D.P.; Alfieri, A.A.; Balarim, M.R.S. [Universidade Estadual de Londrina, PR (Brazil). Faculdade de Medicina Veterinaria e Zootecnia. Dept. de Medicina Veterinaria Preventiva]. E-mail: rnetto@uel.br; Chiacchio, S.B.; Bicudo, P.L. [UNESP, Botucatu, SP (Brazil). Faculdade de Medicina Veterinaria e Zootecnia; Nascimento, N. [Instituto de Pesquisas Energeticas e Nucleares (IPEN), Sao Paulo, SP (Brazil). Supervisao de Radiobiologia

    2004-07-01

    Natural (NV) and Cobalt{sub 60}-irradiated (IrV) Crotalus durissus terrificus venom were used to evaluate serum production capacity of sheep and possible hematological and biochemical effects. Freeze-dried venom aliquots were diluted in acidified saline solution (NaCl 150 m M, p H 3.0) and irradiated by a Cobalt 60 source at a dose of 5.54 x 102 Gy/h and a concentration of 2.000 Gy. Twelve sheep were divided into two groups of six animals. One group received irradiated venom (IrV) and the other natural venom (NV). Three antigen doses (venom) were administered at monthly intervals. Blood samples were collected weekly for analysis of serum neutralization potency and capacity, complete blood count, total plasma protein, fibrinogen, albumin, and globulin. At the end of the experiment, the animals were challenged with a LD{sub 50} for sheep and showed no signs of envenoming. The two groups did not present clinical alterations. Results of the total leukocyte count did not present interaction or time factor effect for both groups, but there was a different action between them, with the NV group presenting more cells than the IrV group. The leukocyte increase to 13,000/{mu}l indicates that slight leucocytosis occurred in the week after the first inoculation in the NV group. There was no statistically significant difference between groups in the absolute count of segmented neutrophils, eosinophils, and lymphocytes but there were statistically significant oscillations in values at the different collecting times. The NV group presented an increase in the absolute neutrophil count after the first inoculation that persisted for 5 weeks. In the IrV group, the increase in neutrophils occurred only in the first week returning to normal in the following weeks. The alterations in the neutrophil count are indicative of systemic inflammatory response related to cytokine release; response was more marked in the N V group, showing its greater toxicity. (author)

  17. Analysis and development of methods of correcting for heterogeneities to cobalt-60: computing application

    International Nuclear Information System (INIS)

    Kappas, K.

    1982-11-01

    The purpose of this work is the analysis of the influence of inhomogeneities of the human body on the determination of the dose in Cobalt-60 radiation therapy. The first part is dedicated to the physical characteristics of inhomogeneities and to the conventional methods of correction. New methods of correction are proposed based on the analysis of the scatter. This analysis allows to take account, with a greater accuracy of their physical characteristics and of the corresponding modifications of the dose: ''the differential TAR method'' and ''the Beam Substraction Method''. The second part is dedicated to the computer implementation of the second method of correction for routine application in hospital [fr

  18. A national survey of HDR source knowledge among practicing radiation oncologists and residents: Establishing a willingness-to-pay threshold for cobalt-60 usage.

    Science.gov (United States)

    Mailhot Vega, Raymond; Talcott, Wesley; Ishaq, Omar; Cohen, Patrice; Small, Christina J; Duckworth, Tamara; Sarria Bardales, Gustavo; Perez, Carmen A; Schiff, Peter B; Small, William; Harkenrider, Matthew M

    Ir-192 is the predominant source for high-dose-rate (HDR) brachytherapy in United States markets. Co-60, with longer half-life and fewer source exchanges, has piloted abroad with comparable clinical dosimetry but increased shielding requirements. We sought to identify practitioner knowledge of Co-60 and establish acceptable willingness-to-pay (WTP) thresholds for additional shielding requirements for use in future cost-benefit analysis. A nationwide survey of U.S. radiation oncologists was conducted from June to July 2015, assessing knowledge of HDR sources, brachytherapy unit shielding, and factors that may influence source-selection decision-making. Self-identified decision makers in radiotherapy equipment purchase and acquisition were asked their WTP on shielding should a more cost-effective source become available. Four hundred forty surveys were completed and included. Forty-four percent were ABS members. Twenty percent of respondents identified Co-60 as an HDR source. Respondents who identified Co-60 were significantly more likely to be ABS members, have attended a national brachytherapy conference, and be involved in brachytherapy selection. Sixty-six percent of self-identified decision makers stated that their facility would switch to a more cost-effective source than Ir-192, if available. Cost and experience were the most common reasons provided for not switching. The most common WTP value selected by respondents was decision makers to establish WTP for shielding costs that source change to Co-60 may require. These results will be used to establish WTP threshold for future cost-benefit analysis. Copyright © 2017 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.

  19. EFTF cobalt test assembly results

    International Nuclear Information System (INIS)

    Rawlins, J.A.; Wootan, D.W.; Carter, L.L.; Brager, H.R.; Schenter, R.E.

    1988-01-01

    A cobalt test assembly containing yttrium hydride pins for neutron moderation was irradiated in the Fast Flux Test Facility during Cycle 9A for 137.7 equivalent full power days at a power level fo 291 MW. The 36 test pins consisted of a batch of 32 pins containing cobalt metal to produce Co-60, and a set of 4 pins with europium oxide to produce Gd-153, a radioisotope used in detection of the bone disease Osteoporosis. Post-irradiation examination of the cobalt pins determined the Co-60 produced with an accuracy of about 5 %. The measured Co-60 spatially distributed concentrations were within 20 % of the calculated concentrations. The assembly average Co-60 measured activity was 4 % less than the calculated value. The europium oxide pins were gamma scanned for the europium isotopes Eu-152 and Eu-154 to an absolute accuracy of about 10 %. The measured europium radioisotpe anc Gd-153 concentrations were within 20 % of calculated values. In conclusion, the hydride assembly performed well and is an excellent vehicle for many Fast Flux Test Facility isotope production applications. The results also demonstrate that the calculational methods developed by the Westinghouse Hanford Company are very accurate. (author)

  20. The physiological effect of cobalt on watermelon cultivation

    International Nuclear Information System (INIS)

    Yao Naihua; Jin Yafang; Sun Yaochen; Huang Yiming

    1993-01-01

    Cobalt has essential physiological action on both animals and plants. For the latter it can raise plant's nitrogen-fixing ability and saccharine content. Spray of cobalt mixed with other nutritive elements can improve the germinatit of seeds and the yield of fruit. For specifying the nutritive function of cobalt upon watermelon, isotope 60 Co was mixed into a complex leaf nutritive aqua and the regularity of transferring and absorbing cobalt in the watermelon's body was investigated

  1. Disinfection of the bee hive's American Foulbrood by gamma radiation from Cobalt-60

    International Nuclear Information System (INIS)

    Gosselin, P.; Charbonneau, R.

    1990-01-01

    Gamma radiation from Cobalt-60 was used to sterilize honeybee combs contaminated by Bacillus larvae. The determination of the radiosensitivity (D 10 ) was done on cultured cells in Brain Heart Infusion broth and was found to be determined at 125 Gy. The D 10 of isolated spores from contaminated combs was then determined at 0,518 kGy and the D 10 of spores irradiated in their own original environment was found at 2,05 kGy. These treated combs were then sent back in the beehives. The bees cleaned the combs thoroughly and started the storage of honey in some cells. Eggs were also layed in others. Forty five days later, there were still no sing of re-appearance of the American Foulbrood disease. (author)

  2. Dose measurements for characterization of a semi-industrial cobalt-60 gamma-irradiation facility

    International Nuclear Information System (INIS)

    Farah, K.; Jerbi, T.; Kuntz, F.; Kovacs, A.

    2006-01-01

    Cobalt-60 irradiation facility has been put into operation at the National Centre of Nuclear Sciences and Technology, Sidi-thabet, Tunisia. Its technical specifications were controlled by dosimetry commissioning experiments and compared to the data specified by the plant manufacturer. Installation qualification has been carried out to measure absorbed dose distribution in the irradiation cell and products. Two dosimeter systems were used for measurements: Red and Amber Perspex and Cellulose Triacetate (CTA). The regions of minimum and maximum absorbed dose within a homogeneous dummy product (sawdust) with a bulk density of 114kg/m 3 and the dose uniformity ratio were determined. The isodose curves and the three-dimensional views were built using an automatic geostatistical gridding method, the kriging method

  3. Cobalt metabolism and toxicology—A brief update

    International Nuclear Information System (INIS)

    Simonsen, Lars Ole; Harbak, Henrik; Bennekou, Poul

    2012-01-01

    discipline. As another new potential source of cobalt exposure, suspicion has been raised that cobalt salts may be misused by athletes as an attractive alternative to Epo doping for enhancing aerobic performance. The cobalt toxicity in vitro seems to reside mainly with ionized cobalt. It is tempting to speculate that ionized cobalt is also the primary toxic form for systemic toxicity in vivo. Under this assumption, the relevant parameter for risk assessment would be the time-averaged value for systemic cobalt ion exposure that from a theoretical point of view might be obtained by measuring the cobalt content in red cells, since their cobalt uptake reflects uptake only of free ionized cobalt (Co 2+ ), and since the uptake during their 120 days life span is practically irreversible. This clearly calls for future clinical studies in exposed individuals with a systematic comparison of concurrent measurements of cobalt concentration in red cells and in serum.

  4. Construction of an apparatus for nuclear orientation measurements at low temperatures. Application to neodymium-cobalt alloy

    International Nuclear Information System (INIS)

    Mayer, E.

    1965-10-01

    We describe experiments along which has been studied the anisotropy of γ radiations emitted by oriented nuclei. We have used the great hyperfine fields acting on nuclei in ferromagnetic metals so as to produce alignment at low temperature. By irradiation we obtained a few cobalt 60 nuclei in our samples which were then cooled down to 0,01 K. The anisotropic rate of the 1,33 MeV γ radiation was measured in function of the sample temperature, using as thermometer the anisotropy of γ radiation emitted by cobalt 60 nuclei in a cobalt single crystal. Cobalt 60 was lined up in a cobalt nickel alloy (40% Ni). The hyperfine field at the cobalt was measured compared to the effective field in metallic cobalt: Heff(Co Ni)/Heff(Co metal) = 0.71 ± 0.12. These results are in good agreement with specific heat measurements made previously. Cobalt 60 has been polarised in a neodymium-cobalt alloy (NdCo 5 ). The field at the cobalt in NdCo 5 has been measured compared to the field in metallic cobalt and taking the non-saturation into account we found 165000 oersteds 5 ) [fr

  5. Autonomous monitoring unit, signs and registration for Cobalt-60 irradiator safety system

    Energy Technology Data Exchange (ETDEWEB)

    Baldaconi, Ricardo H.; Costa, Fabio E. da, E-mail: ricardohovacker@hotmail.com, E-mail: fecosta@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2015-07-01

    The Cobalt-60 irradiator of IPEN / CNEN, a category IV facility, has a security system for inter locking doors or exposure of radioactive sources made simultaneously by a programmable logic controller (PLC) model S7- 200 from Siemens and a relay logic. From a set of information, the both systems work together opening doors or exposing the sources. All incoming and outgoing information are sent serially via EIA232 communication to a personal computer with Windows® platform for a supervisory program which provides besides a monitoring the entire process by a synoptic table on the computer screen, also keeps records of all events on the computer's hard drive. The electronic management has proven to be efficient and has not produced any failure that had compromised the safety. The PLC along with the relay logic has always taken the right decisions ensuring proper radiation protection of operators and the integrity of radioactive sources, but it presented over the years of operation (beginning in 2004) less than a dozen flaws in system event log. The deficiency was found between the process of sending events via serial communication (EIA232) to the supervisory program. When failure occurs in a very short time, the PLC always took the right decision, but the registration process that had to go through the Windows® timeshare lost the information. This work aimed to build a standalone electronics connect the inputs and outputs of the security system, fully optocoupled to avoid any interference to the security system. It records each event on a memory card, waits for the right decision of the security system and in case of an incorrect decision an independent alarm notifies its own synoptic picture, and sends a text message to a group of defined cell phones. The circuit uses two microcontrollers called 'main' and 'secondary'. The main is responsible for the control and monitoring of peripheral inputs and outputs of the security system. The main is

  6. Autonomous monitoring unit, signs and registration for Cobalt-60 irradiator safety system

    International Nuclear Information System (INIS)

    Baldaconi, Ricardo H.; Costa, Fabio E. da

    2015-01-01

    The Cobalt-60 irradiator of IPEN / CNEN, a category IV facility, has a security system for inter locking doors or exposure of radioactive sources made simultaneously by a programmable logic controller (PLC) model S7- 200 from Siemens and a relay logic. From a set of information, the both systems work together opening doors or exposing the sources. All incoming and outgoing information are sent serially via EIA232 communication to a personal computer with Windows® platform for a supervisory program which provides besides a monitoring the entire process by a synoptic table on the computer screen, also keeps records of all events on the computer's hard drive. The electronic management has proven to be efficient and has not produced any failure that had compromised the safety. The PLC along with the relay logic has always taken the right decisions ensuring proper radiation protection of operators and the integrity of radioactive sources, but it presented over the years of operation (beginning in 2004) less than a dozen flaws in system event log. The deficiency was found between the process of sending events via serial communication (EIA232) to the supervisory program. When failure occurs in a very short time, the PLC always took the right decision, but the registration process that had to go through the Windows® timeshare lost the information. This work aimed to build a standalone electronics connect the inputs and outputs of the security system, fully optocoupled to avoid any interference to the security system. It records each event on a memory card, waits for the right decision of the security system and in case of an incorrect decision an independent alarm notifies its own synoptic picture, and sends a text message to a group of defined cell phones. The circuit uses two microcontrollers called 'main' and 'secondary'. The main is responsible for the control and monitoring of peripheral inputs and outputs of the security system. The main is

  7. Cobalt metabolism and toxicology-A brief update

    Energy Technology Data Exchange (ETDEWEB)

    Simonsen, Lars Ole, E-mail: LOSimonsen@dadlnet.dk; Harbak, Henrik; Bennekou, Poul

    2012-08-15

    concept of nanotoxicology a crucial, new discipline. As another new potential source of cobalt exposure, suspicion has been raised that cobalt salts may be misused by athletes as an attractive alternative to Epo doping for enhancing aerobic performance. The cobalt toxicity in vitro seems to reside mainly with ionized cobalt. It is tempting to speculate that ionized cobalt is also the primary toxic form for systemic toxicity in vivo. Under this assumption, the relevant parameter for risk assessment would be the time-averaged value for systemic cobalt ion exposure that from a theoretical point of view might be obtained by measuring the cobalt content in red cells, since their cobalt uptake reflects uptake only of free ionized cobalt (Co{sup 2+}), and since the uptake during their 120 days life span is practically irreversible. This clearly calls for future clinical studies in exposed individuals with a systematic comparison of concurrent measurements of cobalt concentration in red cells and in serum.

  8. Pseudo-dynamic source modelling with 1-point and 2-point statistics of earthquake source parameters

    KAUST Repository

    Song, S. G.

    2013-12-24

    Ground motion prediction is an essential element in seismic hazard and risk analysis. Empirical ground motion prediction approaches have been widely used in the community, but efficient simulation-based ground motion prediction methods are needed to complement empirical approaches, especially in the regions with limited data constraints. Recently, dynamic rupture modelling has been successfully adopted in physics-based source and ground motion modelling, but it is still computationally demanding and many input parameters are not well constrained by observational data. Pseudo-dynamic source modelling keeps the form of kinematic modelling with its computational efficiency, but also tries to emulate the physics of source process. In this paper, we develop a statistical framework that governs the finite-fault rupture process with 1-point and 2-point statistics of source parameters in order to quantify the variability of finite source models for future scenario events. We test this method by extracting 1-point and 2-point statistics from dynamically derived source models and simulating a number of rupture scenarios, given target 1-point and 2-point statistics. We propose a new rupture model generator for stochastic source modelling with the covariance matrix constructed from target 2-point statistics, that is, auto- and cross-correlations. Our sensitivity analysis of near-source ground motions to 1-point and 2-point statistics of source parameters provides insights into relations between statistical rupture properties and ground motions. We observe that larger standard deviation and stronger correlation produce stronger peak ground motions in general. The proposed new source modelling approach will contribute to understanding the effect of earthquake source on near-source ground motion characteristics in a more quantitative and systematic way.

  9. Treatment of radioactive liquid waste (Co-60) by sorption on Zeolite Na-A prepared from Iraqi kaolin.

    Science.gov (United States)

    Mustafa, Yasmen A; Zaiter, Maysoon J

    2011-11-30

    Iraqi synthetic zeolite type Na-A has been suggested as ion exchange material to treat cobalt-60 in radioactive liquid waste which came from neutron activation for corrosion products. Batch experiments were conducted to find out the equilibrium isotherm for source sample. The equilibrium isotherm for radioactive cobalt in the source sample showed unfavorable type, while the equilibrium isotherm for the total cobalt (the radioactive and nonradioactive cobalt) in the source sample showed a favorable type. The ability of Na-A zeolite to remove cobalt from wastewater was checked for high cobalt concentration (822 mg/L) in addition to low cobalt concentration in the source sample (0.093 mg/L). A good fitting for the experimental data with Langmuir equilibrium model was observed. Langmuir constant qm which is related to monolayer adsorption capacity for low and high cobalt concentration was determined to be 0.021 and 140 mg/g(zeolite). The effects of important design variables on the zeolite column performance were studied these include initial concentration, flow rate, and bed depth. The experimental results have shown that high sorption capacity can be obtained at high influent concentration, low flow rate, and high bed depth. Higher column performance was obtained at higher bed depth. Thomas model was employed to predict the breakthrough carves for the above variables. A good fitting was observed with correlation coefficients between 0.915 and 0.985. Copyright © 2011 Elsevier B.V. All rights reserved.

  10. Radioactive and stable cobalt concentrations in mussel in Kyushu island, Japan

    International Nuclear Information System (INIS)

    Momoshima, Noriyuki; Shiki, Atsushi; Takashima, Yoshimasa; Maki, Takao; Koriyama, Munehiro; Shimozono, Seika; Imamura, Hiroka; Nakamata, Kojiro.

    1985-01-01

    Two kinds of mussel, Septifer virgatus and Mytilus edulis, were collected from Kyushu island, Japan, in order to elucidate a background level of 60 Co, which is one of the most significant radionuclide for environmental monitoring around a nuclear power plant. The mussels were collected from 7 locations in 1983 and classified 2 or 3 groups depending on their shell size at each location. Activities of 60 Co were measured by a low-background β counter after purified by means of chemical separation and electrodeposition. Stable cobalt concentrations were determined by colorimetric method. The concentrations of cobalt in Septifer virgatus are one order higher level than that in Mytilus edulis. There are not so large difference in cobalt content depending on shell size so long as comparing them at the same location. The radioactivities in mussels show the same trend as stable cobalt. It has become apparent that Septifer virgatus has a tendency to concentrate cobalt with growing but Mytilus edulis is opposite. The cobalt-60 introduced to sea from nuclear explosions seems to be relatively constant in coastal seawater since specific activities are distributed in a narrow range in spite of kind, shell size and location. (author)

  11. Design and tests of a package for the transport of radioactive sources

    International Nuclear Information System (INIS)

    Santos, Paulo de Oliveira

    2011-01-01

    The Type A package was designed for transportation of seven cobalt-60 sources with total activity of 1 GBq. The shield thickness to accomplish the dose rate and the transport index established by the radioactive transport regulation was calculated by the code MCNP (Monte Carlo N-Particle Transport Code Version 5). The sealed cobalt-60 sources were tested for leakages. according to the regulation ISO 9978:1992 (E). The package was tested according to regulation Radioactive Material Transport CNEN. The leakage tests results pf the sources, and the package tests demonstrate that the transport can be safe performed from the CDTN to the steelmaking industries

  12. Calibration of angle response of a NaI(Tl) airborne spectrometer to 137Cs and 60Co point sources on the ground

    International Nuclear Information System (INIS)

    Liu Xinhua; Zhang Yongxing; Gu Renkang; Shen Ensheng

    1998-01-01

    The angle response function F(φ,θ) is a basic calibration of airborne spectrometers in airborne surveying for nuclear emergency monitoring. The author describes the method and results of angle response function calibration of a NaI(Tl) airborne spectrometer for 137 Cs and 60 Co point sources on the ground, with less than 20% uncertainty. By using the results, the calibration factors of the NaI(Tl) airborne spectrometer fixed in Yun-5 plane at different flying heights are calculated by numerical integral method for 137 Cs uniform area source on ground surface, with less than 25% uncertainty. The minimum detection limits (L D ) are calculated at 90 m and 120 m flying heights in the range of over Shijiazhuang airborne surveying for 137 Cs uniform area source on ground surface to be 3.83 and 5.62 kBq/m 2 , respectively

  13. Cobalt production in RAPS-1

    International Nuclear Information System (INIS)

    Krishnan, P.D.; Purandare, H.D.

    1978-01-01

    At present in RAPS-1 radioisotope Co 60 is produced by irradiating Co 59 in the adjusters which perform the function of regulation of reactivity, power and xenon override. But the manrem expenditure of the crew handling the charge and discharge of the adjusters is going to be prohibitively high. It is therefore proposed to irradiate Co 59 in the fuel channel positions. The physics optimisation study for such irradiation is presented. The burnup penalty and loss of power are estimated to produce the required quantity of Co 60 after optimising the number of cobalt pencils in a bundle and the positions of the cobalt producing channels in the reactor core. (author)

  14. Late effects of protracted whole-body irradiation of beagles by cobalt-60 gamma rays

    International Nuclear Information System (INIS)

    Fritz, T.E.; Seed, T.M.; Tolle, D.V.; Lombard, L.S.

    1986-01-01

    So that a stronger basis for extrapolation of low-level radiation effects to man can be provided, existing data from small laboratory animals are being supplemented by studies in a longer lived animal, the dog. Beagle dogs are exposed to continuous cobalt-60 irradiation either throughout life or until predetermined total doses are accumulated. The radiation-specific excess-mortality rate and associated causes of death will be related to both dose rate and total dose. The ongoing studies also emphasize the pathogenesis of myelogenous leukemia. At dose rates of 3.75 to 26.25 rads/day, given continuously, responses were consistent, highly dose-rate dependent, and limited primarily to the hematopoietic system. At rates as low as 0.3 rad/day, the hematopoietic system is still the limiting factor for survival, but below 3.75 rads/day present evidence suggests that the responses are independent of dose rate. Longitudinal studies of peripheral blood and bone marrow detected four preclinical phases of myelogenous leukemia. These phases were characterized by standard hematologic end points, ultrastructural features, in vitro cloning assays, and the acute radiation sensitivity of stem cells. Results suggest that an induced error-prone repair mechanism is the basis for the onset of radiation-induced myelogenous leukemia. Interim data from dogs given terminated exposures suggest that the types of tumors and times to death are different from controls but the numbers of tumors are not yet greater than in controls. 26 refs., 12 figs., 5 tabs

  15. Report on salvage of a jammed cobalt-60 source of the gamma beam irradiator at Bangladesh Institute of Nuclear Agriculture (BINA), Mymensingh, Bangladesh

    International Nuclear Information System (INIS)

    Karim, S.M.F.; Awal, K.O.; Ali, M.A.T.

    1997-01-01

    This report is the follow-up of a recovery plan for a Co-60 source that was presented at the proceedings of a symposium at the International Atomic Energy Agency, Vienna during 6-10 November 1989. This report deals mainly with technical measures adopted to salvage the jammed Co-60 source of a gamma irradiator at the Bangladesh Institute of Nuclear Agriculture BINA, Mymensingh, Bangladesh. Different tools and devices were developed to allow the remote recovery of the source. The radiation safety measures taken and the device drawings are given, together with suggestions for future use of the source with the remaining activity for irradiation purposes. (author)

  16. Distribution of cobalt 60 in a mollusc, a crustacean and a freshwater teleost: variations as a function of the source of pollution and during elimination

    International Nuclear Information System (INIS)

    Amiard, J.C.; Amiard-Triquet, C.

    1979-01-01

    57 Co, 58 Co and 60 Co are present in nuclear test debris as well as in effluents of the non-military nuclear industry. The stable isotope, which is a constituent of vitamin B 12 , has very important biological functions. For each species, three experiments were carried out: (1) starved animals were immersed in 60 Co-contaminated water; (2) animals were immersed in contaminated water and received radioactive food and (3) animals were placed in fresh water without any pollutant but received contaminated food. Radiation doses were calculated for contamination via both food and water. When 60 Co is taken up directly from water, the most contaminated organs are external ones, especially the shell of the snail Lymnaea palustris and the exoskeleton and feeding appendages of the crayfish Astacus leptodactylus. Contamination via food is responsible for a relatively greater accumulation of radiocobalt in internal organs. The cobalt content of muscles - that is to say the edible parts of crayfish and common carp Cyprinus carpio -is very low. The highest concentrations recorded are in the visceral mass of the snail, the digestive gland of the crayfish and the kidneys of the carp. Internal doses for these organs are considerably higher than those for entire animals. Therefore, as a result of 60 Co distribution, they are critical organs for the freshwater species. Except for the carp, external radiation is very weak compared with internal radiation. A strong retention of 60 Co is observed for the shell of L. palustris while the desorption of radiocobalt from the exoskeleton of A. leptodactylus is easier. In carp, the 60 Co taken up by the gut from food, as well as from water, is rapidly eliminated. (author)

  17. Radiological safety aspects during handling of adjuster rod (cobalt-60) samples at Cirus

    International Nuclear Information System (INIS)

    Yadav, R.K.B.; Prasad, S.K.; Khuspe, R.R.; Babu, K.S.; Kamble, M.K.; Deshpande, S.B.; Srivastava, Alok; Ramesh, N.; Sharma, R.C.

    2008-01-01

    Cobalt -60 produced from the irradiation of the 59 Co capsules in adjuster rod of Cirus is used in many medical and industrial applications such as radiation therapy, sterilization of agricultural products, sterilization of medical equipment, industrial gamma exposure devices, nucleonic gauging sources etc. Two adjuster rods used for adjusting small reactivity loads (3.5 mk at 40 MW) in reactor contain thirty 59 Co slugs each. The 59 Co slugs are in the form of small capsules. These slugs were irradiated for nearly 3 years of full power operation. Since the amount of activity handled in the adjuster rod is very high (35 - 40 kCi), adequate radiological safety coverage is to be provided during the transfer of adjuster rod from the reactor pile to Tray Rod Facility (TRF) and during remote handling and loading of adjuster rod samples in shipping flask at TRF. Radiation fields observed are 0.4 - 3.0 Gy/h. In Cirus, falling of Adjuster rod from vertical flask at top of pile could result in declaration of evacuation emergency due to potential hazards associated with the high radiation field (∼26 Gy/h at 1m) of 60 Co slugs. Entire process of remote handling is viewed through lead glass and movement of samples is carried out with the help of a pair of master slave manipulator (MSM) arms. TRF with full samples give a radiation background of 0.2 - 20 mGy/h, requiring control of movement of personnel in the area. This paper explains in detail about the health physics aspects during handling of adjuster rod from reactor pile to TRF and back to pile, unloading and loading of radioisotope samples, operational radiation protection experience gained and collective dose consumed for the above transfer and loading job. The collective dose consumed in the handling of two adjuster rods is 8.7 per-mSv. (author)

  18. Cobalt reduction of NSSS valve hardfacings for ALARA

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Joo Hak; Lee, Sang Sub [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of)

    1994-07-01

    This report informs NSSS designer that replacement of materials is one of the major means of ALARA implementation, and describes that NSSS valves with high-cobalt hardfacing are significant contributors to post-shutdown radiation fields caused by activation of cobalt-59 to cobalt-60. Generic procedures for implementing cobalt reduction programs for valves are presented. Discussions are presented of the general and specific design requirements for valve hardfacing in nuclear service. The nuclear safety issues involved with changing valve hardfacing materials are discussed. The common methods used to deposit hardfacing materials are described together with an explanation of the wear measurements. Wear resistance, corrosion resistance, friction coefficient, and mechanical properties of candidate hardfacing alloys are given. World-wide nuclear utility experience with cobalt-free hardfacing alloys is described. The use of low-cobalt or cobalt-free alloys in other nuclear plant components is described. 17 figs., 38 tabs., 18 refs. (Author).

  19. Cobalt reduction of NSSS valve hardfacings for ALARA

    International Nuclear Information System (INIS)

    Kim, Joo Hak; Lee, Sang Sub

    1994-07-01

    This report informs NSSS designer that replacement of materials is one of the major means of ALARA implementation, and describes that NSSS valves with high-cobalt hardfacing are significant contributors to post-shutdown radiation fields caused by activation of cobalt-59 to cobalt-60. Generic procedures for implementing cobalt reduction programs for valves are presented. Discussions are presented of the general and specific design requirements for valve hardfacing in nuclear service. The nuclear safety issues involved with changing valve hardfacing materials are discussed. The common methods used to deposit hardfacing materials are described together with an explanation of the wear measurements. Wear resistance, corrosion resistance, friction coefficient, and mechanical properties of candidate hardfacing alloys are given. World-wide nuclear utility experience with cobalt-free hardfacing alloys is described. The use of low-cobalt or cobalt-free alloys in other nuclear plant components is described. 17 figs., 38 tabs., 18 refs. (Author)

  20. The Co{sup 60} Irradiation Facility and the Gamma Field at Riso; Appareil d'irradiation au cobalt-60 et champ sous irradiation gamma, a Riso; Ustanovka dlya obluchenij, rabotayushchaya na So60, i pole gamma-luchej v rizo; Instalacion de irradiacion con cobalto-60 y campo de irradiacion gamma en el centro de Riso

    Energy Technology Data Exchange (ETDEWEB)

    Brynjolfsson, A; Holm, N W [Danish Atomic Energy Commission, Establishment Riso (Denmark)

    1960-07-15

    The paper describes both the Co{sup 60} irradiation facility and the gamma field at the Agricultural Department of the Research Establishment, Riso. The Co{sup 60} irradiation facility contains 1,800 curies of Co{sup 60.} Details of the construction are given together with the safety precautions which have been included in the design. Dosimetry has been carried out by four different methods: 1. Ionisation chambers, 2. Calorimetry, 3. Fricke dosimeter, 4. Photographic films. A general outline is given of the gamma field, including details of source position. The dose rate is approximately 100 r./hr. at a distance of 1 m. An area of radius 15 m is used for the growing of plants under irradiation. A brief indication is given of the class of products which have been irradiated in the two facilities. (author) [French] Le memoire decrit l'appareil d'irradiation au cobalt-60 et le champ sous irradiation gamma du Departement de l'agriculture de l'Organisme de recherche de Riso. L'appareil d'irradiation au cobalt-60 contient une source de 1 800 curies. Des details sont donnes sur la construction ainsi que sur les dispositifs de protection compris dans le plan. Quatre methodes differentes ont ete utilisees pour la dosimetrie: 1. Chambres d'ionisation 2. Calorimetrie 3. Dosimetrie de Fricke 4. Pellicules photographique s On donne un apercu general du champ gamma, ainsi que des details sur la position de la source. L'intensite de dose est de 100 R/h environ a une distance de 1 m. Une zone d'un rayon de 15 m est utilisee pour la croissance des plantes soumises a l'irradiation. Des indications sommaires sont donnees sur la categorie des produits qui ont ete soumis a l'irradiation dans les deux installations. (author) [Spanish] Los autores describen la instalacion de irradiacion con cobalto-60 y el campo de irradiacion gamma del Departamento de Agronomia del Instituto de Investigaciones de Riso. El dispositivo de irradiacion consiste en una fuente de cobalto-60 de 1 800 curies

  1. The Relation of Design Parameters, Plant Capacity and Processing Costs in Cobalt-60 Sterilization Plants

    International Nuclear Information System (INIS)

    Brown, M.G.

    1967-01-01

    The paper describes the main features of three basic types of cobalt-60 sterilization plants which have been designed to provide a complete range of capacities for radiosterilization of medical products. The smallest plant has a capacity of up to 50 000 cubic feet of medical products a year, the intermediate size plant has a capacity of up to 500 000 cubic feet a year, and the largest plant has a capacity in excess of 1000 000 cubic feet a year. The relations between capital costs, rate of production, efficiency and unit processing costs for each type of plant are discussed. The method of selecting the best type of plant for a particular need will also be outlined. (author)

  2. Photoacoustic Point Source

    International Nuclear Information System (INIS)

    Calasso, Irio G.; Craig, Walter; Diebold, Gerald J.

    2001-01-01

    We investigate the photoacoustic effect generated by heat deposition at a point in space in an inviscid fluid. Delta-function and long Gaussian optical pulses are used as sources in the wave equation for the displacement potential to determine the fluid motion. The linear sound-generation mechanism gives bipolar photoacoustic waves, whereas the nonlinear mechanism produces asymmetric tripolar waves. The salient features of the photoacoustic point source are that rapid heat deposition and nonlinear thermal expansion dominate the production of ultrasound

  3. Cobalt sorption onto Savannah River Plant soils

    International Nuclear Information System (INIS)

    Hoeffner, S.L.

    1985-06-01

    A laboratory study of cobalt-60 sorption was conducted using Savannah River Plant soil and groundwater from the low-level waste burial ground. Systematic variation of soil and water composition indicates that cobalt sorption is most strongly a function of pH. Over a pH range of 2 to 9, the distribution coefficient ranged from 2 to more than 10,000 mL/g. Changes in clay content and in K + , Ca 2+ , or Mg 2+ concentrations influence cobalt sorption indirectly through the slight pH changes which result. The ions Na + , Cl - , and NO 3 - have no effect on cobalt sorption. Ferrous ion, added to groundwater to simulate the condition of water at the bottom of the waste trenches, accounts for part of the decrease in cobalt sorption observed with trench waters. 17 refs., 3 figs., 4 tabs

  4. Different gamma ray (60 Co) dose effects on Sorghum genotype germination

    International Nuclear Information System (INIS)

    Tabosa, Jose Nildo; Gomes, Roberto Vicente; Reis, Odemar Vicente dos; Colaco, Waldeciro

    2004-01-01

    In agriculture, applying irradiation is a very valuable way of obtaining vegetable products for human and animal consumption. Cobalt-60, one of the main sources of gamma-rays, is considered an important tool in plant breeding programs, which have the objective of promoting genetic variability of cultivars with resistance to adverse environments. In this research, the effects of different 60 Co doses on germination vigor and seed germination velocity of forage sorghum genotypes were evaluated. The study was carried out at the IPA (Empresa Pernambucana de Pesquisa Agropecuaria) in Recife, Pernambuco, Brazil. The work was installed in germination boxes, following laboratory recommendations. Thus, a experiment involving three sorghum genotypes (IPA 467-4-2, IPA 02-03-01, and Sudan 4202), five 60 Co doses (Zero, 150, 300, 350, and 400 Gy), was set up. The sees were irradiated before the beginning of the experiment being exposed to gamma rays from a 60 Co-source (cobalt irradiator) at DEN (Nuclear Engineering Department) of the UFPE (Pernambuco Federal University), Brazil. The work also had the objective of evaluating the sorghum genotypes x 60 Co dose interaction. The main results obtained showed that the sorghum genotype IPA 02-03-01 presented the greatest values of germination and vigor percentages, and seed germination velocity, when compared to the others evaluated, on 350 and 400 Gy of 60 Co doses. (author)

  5. Effect of Cobalt Source on the Catalyst Reducibility and Activity of ...

    African Journals Online (AJOL)

    The effect of cobalt precursor (nitrate, acetate and chloride salts) on the catalyst reducibility and dispersion, ... balt catalysts (>5.0 wt%) prepared using ammonium cobalt ... heated from 323 K to 1073 K using a heating ramp of 10 K min–1.

  6. Pseudo-dynamic source modelling with 1-point and 2-point statistics of earthquake source parameters

    KAUST Repository

    Song, S. G.; Dalguer, L. A.; Mai, Paul Martin

    2013-01-01

    statistical framework that governs the finite-fault rupture process with 1-point and 2-point statistics of source parameters in order to quantify the variability of finite source models for future scenario events. We test this method by extracting 1-point

  7. The role of cobalt ferrite magnetic nanoparticles in medical science

    Energy Technology Data Exchange (ETDEWEB)

    Amiri, S.; Shokrollahi, H., E-mail: Shokrollahi@sutech.ac.ir

    2013-01-01

    The nanotechnology industry is rapidly growing and promises that the substantial changes that will have significant economic and scientific impacts be applicable to a wide range of areas, such as aerospace engineering, nano-electronics, environmental remediation and medical healthcare. In this area, cobalt ferrite nanoparticles have been regarded as one of the competitive candidates because of their suitable physical, chemical and magnetic properties like the high anisotropy constant, high coercivity and high Curie temperature, moderate saturation magnetization and ease of synthesis. This paper introduces the magnetic properties, synthesis methods and some medical applications, including the hyperthermia, magnetic resonance imaging (MRI), magnetic separation and drug delivery of cobalt ferrite nanoparticles. Highlights: Black-Right-Pointing-Pointer Cobalt ferrite nanoparticles are one of the most important materials for nanomedicine. Black-Right-Pointing-Pointer They have high coercivity and moderate saturation magnetization. Black-Right-Pointing-Pointer Cobalt ferrite nanoparticles are synthesized easily. Black-Right-Pointing-Pointer They are a good candidate for hyperthermia and magnetic resonance imaging.

  8. Cobalt adsorption/desorption on sediments from Piraquara de Fora bay, Angra dos Reis, Brazil

    International Nuclear Information System (INIS)

    Ferreira, Ingryd M.; Carvalho, Franciane M.; Ribeiro, Fernando C.A.; Martins, Nadia S.F.; Peres, Sueli S.; Lauria, Dejanira C.

    2015-01-01

    Among the radionuclides released with the liquid effluents from PWR power plants, cobalt isotopes ( 60 Co and 58 Co) play an important role for risk and environmental impact assessments. The laboratory experiments on radionuclide adsorption-desorption, followed by the use of adsorption isotherms are useful tools for prediction of transport, distribution, accumulation, and fate of a contaminant into a specific medium. Adsorption and desorption experiments were carried out in batches, using two sediment samples collected in Piraquara de Fora Bay, near the discharge channel of the liquid effluents from CNAAA. Aiming the assessment of the radioisotope adsorption mechanisms, sediment samples were shaken with solutions containing cobalt chloride which concentrations ranged between 10 -10 and 10 -3 M. In order to estimate the efficiency of adsorption, 100 Bq of 60 Co were used as radioactive tracer. The experimental data fitted well with Freundlich and Langmuir isotherms. Results point out a favorable and high cobalt adsorption on the sediments, although smaller than the ones reported in literature studies. Such smaller trend of adsorption coefficients may be caused by the low exchange capacity of the prevailing clay, kaolinite. The maximum adsorption capacities were found to be 10 and 17 moles/g for sediments in PT-01 and PT-02, respectively. Values lower than 8% of the adsorbed cobalt underwent desorption and this amount decreased to 4%, with time, which show the high retention capacity of these sediments. (author)

  9. An evaluation of low-energy x-ray and cobalt-60 irradiations of MOS transistors

    International Nuclear Information System (INIS)

    Dozier, C.M.; Fleetwood, D.M.

    1987-01-01

    An evaluation of methodologies for irradiating MOS transistors with low-energy x-ray and Co-60 sources has been performed. The authors find that comparisons of voltage shifts produced by bulk trapped charge and interface states in MOS transistors irradiated using two different low energy x-ray sources (an ARACOR 10 keV W source and an 8 keV Cu source) agree to within better than 30 percent. This quality of agreement is similar in magnitude to that between MOS devices irradiated by different Co-60 sources. In contrast, the measurements indicate that interlaboratory comparisons of ratios of shifts produced by x-ray and Co-60 sources can lead to differences in ratios as large as a factor of --1.7. Improved electron-hole recombination data for oxides is presented. This recombination correction, in conjunction with a correction for interface dose enhancement, is used to predict the ratios of shifts produced by x-ray and Co-60 sources. However, the results show that corrections for electron-hole recombination and interface does enhancement do not, by themselves, adequately predict the field dependent behavior of these transistors

  10. Experiences on the implementation of a postal auditing service to know teletherapy doses using Cobalt 60 attained by the Secondary laboratory for dosimetric calibration from CPHR

    International Nuclear Information System (INIS)

    Campa, R.; Morales, J.A.; Molina, D.; Dominguez, L.

    1998-01-01

    This paper analyzes experiences gained by LSCD from CPHR on the implementation and validation of a postal auditing system. The system checks doses absorbed by water for teletherapy equipment using Cobalt 60. The verification was made with Chinese DTL type JR 1152F (microbars) introduced in capsules developed and employed by IAEA in the postal auditing service for doses IAEA/WHO. The analysis includes the creation of groups of detectors based on their individual sensibility. They have a dispersion range that was almost 2%. Here irradiation was applied to a water dummy. Other tests employed were that for thermal treatment and calibration. Besides one auditing the effectiveness of the postal technique in two facilities using Cobalt 60. The methodology implemented helps to determine doses absorbed in reference conditions with a lower global uncertainty (k=2) (3.2%)

  11. Sterilization of silver acidium pipemedicum skin for the treatment of burns by radioactive cobalt-60-γray

    International Nuclear Information System (INIS)

    Zeng Defeng; Cao Fengsheng; Chen Qinglong; Li Guohui; Su Ziyi; Cao Yong; Wu Wenqing; Qiu Zeyi; Chen Zhanxian

    1995-01-01

    The radiated silver acidum pipemedicum skin (RSAPS) was made of 0.4-0.8mm laminal skin from healthy white pig, which was infiltrated in norfloxacin and silver nitrate, packed with the filkm bag of alummium poil and radiated by cobalt-60γ-ray for sterilization at the dosage of 27.92-35.31Gy/min for a total dose of 25KGY, RSAPS was very effective in sterilization and had no bad effect on elasticity, adhesion, water permeability, and structure of pig skin. So it is highly appreciated by the patients and medical personnel for its convenience of usage and has gained good social and economic beneficial results. (Author)

  12. Irradiation device using radiation sources

    International Nuclear Information System (INIS)

    Perraudin, Claude; Amarge, Edmond; Guiho, J.-P.; Horiot, J.-C.; Taniel, Gerard; Viel, Georges; Brethon, J.-P.

    1981-01-01

    The invention refers to an irradiation appliance making use of radioactive sources such as cobalt 60. This invention concerns an irradiation appliance delivering an easily adjustable irradiation beam in accurate dimensions and enabling the radioactive sources to be changed without making use of intricate manipulations at the very place where the appliance has to be used. This kind of appliance is employed in radiotherapy [fr

  13. Health physics monitoring during cobalt slug rod handling at research reactor Dhruva: an experience

    International Nuclear Information System (INIS)

    Verma, Gopal P.; Bhatnagar, Amit; Krishnamohanan, T.; Kalyanasundaram, N.; Gupta, P.C.; Pushparaja; Ghosh, Runner

    2006-01-01

    Cobalt-60 is used in many industrial and medical applications, such as leveling devices, thickness gauge, sterilization of foodstuff to increase their shelf life, sterilization of medicines and in radiotherapy. The Cobalt slug rod containing cobalt pencils were irradiated for nearly two and half years in the Dhruva reactor core to obtain the 60 Co isotope. It had seen a total irradiation of 29053 MWD and the estimated total activity was 93.321 KCi. Campaign for the removal of irradiated rod from reactor core and retrieval of 60 Co pencils were carried out successfully in Dhruva Reactor complex. In view of such a high activity handled, the job was carried out after exhaustive prior planning and according to approved checklists. Radiation Hazards Control Unit, Dhruva provided Radiation Safety surveillance during the entire handling operation consisting of retrieval of the cobalt pencils and disposal of the aluminum slugs used to house the cobalt pencils in the Cobalt slug rod assembly. The whole operation was carried out in such a safe manner that the total man-rem consumption was insignificant. The operational radiation protection methods followed and the experience gained during the campaign are discussed in this paper. (author)

  14. Sulfur, cobalt and europium activation from the A-bombs in Japan

    International Nuclear Information System (INIS)

    Gritzner, M.L.; Egbert, S.D.; Woolson, W.A.

    1987-01-01

    Comparisons are made between calculations and measurements of in-situ sulfur, cobalt, and europium activation by neutrons at Hiroshima and Nagasaki to check the validity of the neutron sources and transport air-over-ground used in the new Dosimetry System 1986 (DS86). Europium and cobalt are activated by epithermal/thermal neutrons. The sulfur activation has an effective threshold around 2 MeV. Comparisons of sulfur activation at Hiroshima, which necessitate considering the tilt and heading of the cylindrically shaped Little Boy bomb, confirm the high energy neutron portion of the source relevant to sulfur activation. The europium and cobalt activation calculations tend to be higher than the measurements for ground ranges within 300 m and lower than the measurements beyond 700 m. Thus, the cobalt and europium measurements do not validate the source or the transport, embodied in DS87, for those neutrons relevant to europium and cobalt activation. Presently, it is unresolved as to whether the discrepancy can be explained as a problem in the measurements, in their interpretation, or as a problem in the calculations due to the source neutrons and/or their transport from source to the sample site

  15. Effect of cyanide on the distribution of 60Co in mice

    International Nuclear Information System (INIS)

    Frankenberg, L.

    1982-01-01

    The effect of cyanide on the distribution of cobalt was studied by injecting mice i.p. with potassium cyanide 61.4 μmoles/kg, followed 1 min later by 60 CoCl 2 38.5 μmoles/kg i.v. Blood and tissue concentrations of 60 Co were then determined up to 48 h after injection and the results were compared with those obtained from control animals receiving 60 CoCl 2 only. In animals treated with cobalt plus cyanide, considerably higher concentrations of 60 Co were found in the spleen in comparison with controls during the whole observation period, whereas the 60 Co concentration in the pancreas was lower than that of controls during the first 4 h. In other tissues no significant differences between cyanide-treated animals and controls were noticed. Determination of complex-bound cyanide demonstrated that the increased uptake of cobalt in the spleen observed in cyanide-treated animals was due to cobalt-cyanide complex(es). Cyanide did not affect the plasma protein binding of cobalt. (orig.)

  16. The production of Co-60 sealed sources at the National Atomic Energy Commission

    International Nuclear Information System (INIS)

    Freijo, Jose L.

    2002-01-01

    The production and sale of Cobalt 60 by CNEA is in a key momentum for its consolidation, after passing through situations dose to un viability. The sealed sources demand is assured for the next six years and strongly concentrated in the exportation, mainly to the United States and Europe. The project is economically viable even keeping in mind the necessary investments to assure the growing and sustentability of the business. Therefore, it is possible to have realistic and optimists expectation of growing in the medium and long term. To this respect it results fundamental to confront these activities with a medium and long term vision in order to avoid future uncertainties in the project and, at the same time, to guide and motivate the personnel involved in the efforts that necessarily must be performed to achieve the proposed target. The fundamental steps to be concreted are the construction of new production cells and the transformation of the activities into a private development frame through the creation of a commercial society. (author)

  17. Introduction of beam flatness filter for 60Co teletherapy beam and its efficacy in clinical radiotherapy

    International Nuclear Information System (INIS)

    Sathiyan, S.; Ravichandran, R.; Ravikumar, M.

    2003-01-01

    In the western countries cobalt-60 machines have become obsolete, whereas in India we have about 250 machines operational for clinical radiotherapy. The basic differences of 6 MV x-ray beam and cobalt-60 beam are: a) build-up d max point, b) flatness of beam at depths, and c) sharpness of the beam edge. We looked at the homogeneity of delivered dose in the target volume in a 3 field SAD technique for 60 Co (80 cm, 100 cm) and 6 MV treatments. More dose variations are seen in 60 Co treated volume. The excess curvature of isodose curves of 60 Co at depths may be one of the reasons for this inhomogeneity in dose to target volume. Therefore, there is need for achieving perfect flatness in the isodose curves at desired depths. A flattening filter was fabricated using dental wax impression material to account for depths of curvature of 50% 60 Co isodose curve. The filter was fabricated for the Theratron 780C machine for necessary flatness. The beam flatness with filter was measured with a) ionization and b) TL dosimetry methods. The flattened beam profile was compared with 6 MV x-ray beam (Clinac-1800, M/s Varian, USA). Our measurements show uniform flatness of cobalt-60 isodose curve at desired depth and useful radiation field width comparable to 6 MV x-ray photon profile at full width at half maximum (FWHM). If this concept is extendable to short field widths, it appears that there is scope for use of such filter in the treatments of oesophagus, larynx, and pituitary tumours to achieve dose homogeneity. Using this flatness filter and penumbra trimmer, we may achieve better quality cobalt-60 beam for radiotherapy. (author)

  18. Self-powered in-core detectors of cobalt type

    International Nuclear Information System (INIS)

    Jonsson, Georg

    1975-01-01

    Testing and development of self-powered neutron detectors with a cobalt emitter is described. Long term irradiation at 400 deg C is expected to indicate insulation quality, change in calibration and 60 Co build-up. Dynamic tests to investigate possible transient effects due to temperature changes are being performed on a number of detectors up to about 600 deg C. A long term irradiation at low temperature has been terminated after 4.5 years. On completion, neutron dose was estimated to be 5.6 x 10 21 nvt and the 60 Co background was 9.3 % of the full flux signal. A recently introduced long term test is expected to provide data on instability effects due to 61 Co. For a BWR in-core detector installation, the main advantage of cobalt detectors, apart from the small size, appears to be long life. Development work is being done on detectors with vanadium-cobalt emitters, electronic separation of fast and delayed signals and reduction of gamma sensitivity. (O.T.)

  19. Effects of gamma radiation of Cobalt-60 on different phases of the evolutive cycle of pinworm - Tuta absoluta (Meyrich, 1917) (Lepidoptera,Gelechiidae); Efeitos da radiacao gama do Cobalto-60 nas diferentes fases do ciclo evolutivo da traca do tomateiro - Tuta absoluta (Meyrich, 1917) (Lepidoptera, Gelechiidae)

    Energy Technology Data Exchange (ETDEWEB)

    Groppo, Gerson Antonio

    1996-10-01

    The effects of different gamma radiation (Cobalt-60) doses on different phases of the evolutive cycle of Tuta absoluta (Meyrich, 1917) (Lepidoptera, Gelechiidae) have been studied under laboratory conditions in the laboratory of Entomology of Center for Nuclear Energy in Agriculture (CENA), University of Sao Paulo, Piracicaba, Sao Paulo State, Brazil. For all the treatments with gamma radiation a Cobalt-60 source type Gamma beam-650 was used. The doses utilized ranged from of 0,0 (Control) to 3250 Gy with a dose rate of 1110 Gy/h. The experiment was conducted under controlled conditions at 25{+-} 2 deg C, 70 {+-} 5% of relative humidity and photo period of (12:12). It was verified that the lethal doses were: for eggs - 70 Gy; for larvae - 200 Gy e for pupae - 300 Gy. The sterilizing dose for adults from irradiated larvae was 45 Gy. The sterilizing dose for the crossing of irradiated female with normal males (FI X MN) was 100 Gy and for normal female with irradiated male (FN x MI) was 150 Gy, in the both crosses, doses refer to irradiation of pupae. The sterilizing dose for adults, of both sexes, irradiated and crossed with normal adults, (FI x MN) and (FN x MI, were 150 and 200 Gy, respectively. The average longevity of adults, of both sexes, irradiated and crossed with normal adults was 8,3 days. The immediate lethal dose for adults was 3250 Gy. (author)

  20. Cobalt-free nickel-base superalloys

    International Nuclear Information System (INIS)

    Koizumi, Yutaka; Yamazaki, Michio; Harada, Hiroshi

    1979-01-01

    Cobalt-free nickel-base cast superalloys have been developed. Cobalt is considered to be a beneficial element to strengthen the alloys but should be eliminated in alloys to be used for direct cycle helium turbine driven by helium gas from HTGR (high temp. gas reactor). The elimination of cobalt is required to avoid the formation of radioactive 60 Co from the debris or scales of the alloys. Cobalt-free alloys are also desirable from another viewpoint, i.e. recently the shortage of the element has become a serious problem in industry. Cobalt-free Mar-M200 type alloys modified by the additions of 0.15 - 0.2 wt% B and 1 - 1.5 wt% Hf were found to have a creep rupture strength superior or comparable to that of the original Mar-M200 alloy bearing cobalt. The ductility in tensile test at 800 0 C, as cast or after prolonged heating at 900 0 C (the tensile test was done without removing the surface layer affected by the heating), was also improved by the additions of 0.15 - 0.2% B and 1 - 1.5% Hf. The morphology of grain boundaries became intricated by the additions of 0.15 - 0.2% B and 1 - 1.5% Hf, to such a degree that one can hardly distinguish grain boundaries by microscopes. The change in the grain boundary morphology was considered, as suggested previously by one of the authors (M.Y.), to be the reason for the improvements in the creep rupture strength and tensile ductility. (author)

  1. Source term reduction at DAEC (including stellite ball recycling)

    International Nuclear Information System (INIS)

    Smith, R.; Schebler, D.

    1995-01-01

    The Duane Arnold Energy Center was seeking methods to reduce dose rates from the drywell due to Co-60. Duane Arnold is known in the industry to have one of the highest drywell dose rates from the industry standardized 'BRAC' point survey. A prime method to reduce dose rates due to Co-60 is the accelerated replacement of stellite pins and rollers in control rod blades due to their high stellite (cobalt) content. Usually the cobalt content in alloys of stellite is greater than 60% cobalt by weight. During the RFO-12 refueling outage at Duane Arnold, all of the remaining cobalt bearing control rod blades were replaced and new stellite free control rod blades were installed in the core. This left Duane Arnold with the disposal of highly radioactive stellite pins and rollers. The processing of control rod blades for disposal is a very difficult evolution. First, the velocity limiter (a bottom portion of the component) and the highly radioactive upper stellite control rod blade ins and rollers are separated from the control rod blade. Next, the remainder of the control rod blade is processed (chopped and/or crushed) to aid packaging the waste for disposal. The stellite bearings are then often carefully placed in with the rest of the waste in a burial liner to provide shielding for disposal or more often are left as 'orphans' in the spent fuel pool because their high specific activity create shipping and packaging problems. Further investigation by the utility showed that the stellite balls and pins could be recycled to a source manufacturer rather than disposed of in a low-level burial site. The cost savings to the utility was on the order of $200,000 with a gross savings of $400,000 in savings in burial site charges. A second advantage of the recycling of the stellite pins and rollers was a reduction in control in radioactive waste shipments

  2. An analysis of cobalt irradiation in CANDU 6 reactor core

    International Nuclear Information System (INIS)

    Gugiu, E.D.; Dumitrache, I.

    2003-01-01

    In CANDU reactors, one has the ability to replace the stainless steel adjuster rods with neutronically equivalent Co assemblies with a minimum impact on the power plant safety and efficiency. The 60 Co produced by 59 Co irradiation is used extensively in medicine and industry. The paper mainly describes some of the reactor physics and safety requirements that must be carried into practice for the Co adjuster rods. The computations related to the neutronically equivalence of the stainless steel adjusters with the Co adjuster assemblies, as well as the estimations of the activity and the heating of the irradiated cobalt rods are performed using the Monte Carlo codes MCNP5 and MONTEBURNS2.1. The 60 Co activity and heating evaluations are closely related to the neutronics computations and to the density evolution of cobalt isotopes during assumed in-core irradiation period. Unfortunately, the activities of these isotopes could not be evaluated directly using the burn-up capabilities of the MONTEBURNS code because of the lack of their neutron cross-section from the MCNP5 code library. Additional MCNP5 runs for all the cobalt assemblies have been done in order to compute the flux-spectrum, the 59 Co and the 60 Co radiative capture reaction rates in the adjusters. The 60m Co cross-section was estimated using the flux-spectrum and the ORIGEN2.1 code capabilities THERM and RES. These computational steps allowed the evaluation of the one-group cross-section for the radiative capture reactions of cobalt isotopes. The values obtained replaced the corresponding ones from the ORIGEN library, which have been estimated using the flux-spectrum specific to the fuel. The activity values are used to evaluate the dose at the surface of the device designed to transport the cobalt adjusters. (authors)

  3. Main aspects in licensing of a type B(U) package design for the transport of 12.95 PBq of cobalt 60; Aspectos relevantes del licenciamiento en Argentina de un modelo de bulto tipo B(U) para transporte de 12,95 PBq de cobalto 60

    Energy Technology Data Exchange (ETDEWEB)

    Lopez Vietri, J R; Novo, R G; Bianchi, A J

    1996-12-31

    This paper points out the relevant technical issues related to the licensing process, of a type B(U) package design, with cylindrical form and 9.3 ton mass, approved by the Argentine Competent Authority for the transport of 12.95 PBq of cobalt 60 as special form radioactive material. It is briefly described the heat transfer analysis, the structural performance under impulsive loads and the shielding calculation under both normal and accidental conditions of transport, as well as the comparative analysis of the results obtained from design, pre-operational tests and independent evaluation performed by the Argentine Competent Authority to verify the compliance with the Regulations for the Safe Transport of Radioactive Material of the International Atomic Energy Agency. (author). 14 refs., 1 fig., tabs.

  4. Effects of whole-body cobalt 60 gamma irradiation on the young korean native goats

    International Nuclear Information System (INIS)

    Kim, Jong Gyu; Sung, Jai Ki

    1989-01-01

    This study was carried out to investigate the effects of whole-body cobolt-60 gamma irradiation on clinical signs, mortality, hematological, blood chemical, chromosomal and pathologic changes in the young Korean native goats. Groups of goats were exposed to 200, 400, 600 and 800 rads of gamma irradiation from a cobalt-60 source. Clinical signs such as diarrhea, anorexia, weakness and depression of the irradiated goats were observed. Mortalities were 66.7 percent in the group irradiated with 200 rads and 100 percent in the groups irradiated with higher doses. Death times were shortened with the increment of irradiation doses. With time after irradiation, the values of erythrocytes, hemoglobin and packed cell volume decreased in the 200 and 400 rads groups and increased in the 600 and 800 rads groups. The number of total leukocytes of the irradiated goats decreased significantly in all irradiated groups. The degrees of decrease were severe as the irradiated doses were increased. Significant decrease of lymphocyte counts were observed from 6 hours in the 800 rads group and 1 day post irradiation(PI) in all other groups. Post irradiation times for significant reduction of neutrophils were 1, 3, 3 and 5 days for 800, 600, 400 and 200 rads groups, respectively. Serum sorbitol dehydrogenase and serum aspartate aminotransferase activities increased remarkably at 6 hours PI in the 800 rads group and 1 day PI in all other groups. Thereafter the activities returned to normal values. Since mitoses of lymphocytes were completely inhibited in blood cultures of all irradiated goats, chromosomal pictures could not be observed. However, mitoses were observed on 28 days PI in 200 rads group and no abberration in the number and structures of lymphocyte chromosomes were detected. Histopathologic findings in various organs of the irradiated goats were severe necrosis and depletion of lymphoid cells in the lymph nodes and spleen, hypoplasia of hemopoietic cells in the bone marrow

  5. Manganese substituted cobalt ferrite magnetostrictive materials for magnetic stress sensor applications

    OpenAIRE

    Paulsen, J. A.; Ring, A. P.; Lo, C. C. H.; Snyder, John Evan; Jiles, David

    2005-01-01

    Metal bonded cobalt ferrite composites have been shown to be promising candidate materials for use in magnetoelastic stress sensors, due to their large magnetostriction and high sensitivity of magnetization to stress. However previous results have shown that below 60 °C the cobalt ferrite material exhibits substantial magnetomechanical hysteresis. In the current study, measurements indicate that substituting Mn for some of the Fe in the cobalt ferrite can lower the Curie temperature of the ma...

  6. The effect of gaseous ammonia on cobalt perrhenate

    International Nuclear Information System (INIS)

    Maslov, L.P.; Men'shikov, O.D.; Borisov, V.V.; Sorokin, S.I.; Krutovertsev, S.A.; Kharkevich, S.I.; Ivanova, O.M.

    1994-01-01

    The influence of humid air ammonia mixture on crystal pentahydrate of cobalt(2) perrhenate has been studied by the methods of PES, IR spectroscopy thermal analysis and electrophysical measurements. It is shown that with an increase in ammonia content in gaseous phase cobalt perrhenate successively transforms into diaquodiammine-, tetrammine- and μ-dioxo-bis-(tetrammine) derivatives of cobalt. Reversibility of dioxocomplex formation and a correlation between the change in electrophysical properties of crystal sample and change in ammonia content in gaseous phase are pointed out. 16 refs.; 4 figs.; 1 tab

  7. Cobalt deposition studies in the primary circuit under BWR conditions (Phase 1 and 2)

    International Nuclear Information System (INIS)

    Bennett, Peter

    1996-04-01

    This report presents the results from the first 2 phases of an experiment performed to investigate the effects of water chemistry on cobalt transport and deposition in the primary circuit under BWR conditions. Two high pressure water loops have been used to compare the incorporation of cobalt into the oxide films on coupons of various LWR primary circuit constructional materials, with several pretreatments, under Hydrogen Water Chemistry (HWC) and Normal Water Chemistry (NWC) conditions. Cobalt-60 deposition rates onto samples that had been pre-oxidised in air were lower than on samples that had been exposed previously in a water loop or had untreated surfaces. In NWC, oxide layers were thicker, normalised Co-60 deposition rates were higher and Co-60 activities per unit volume of oxide were greater. Some evidence has been produced to support the conclusions of other workers that a chromium-rich outer oxide layer is responsible for enhanced cobalt incorporation. (author)

  8. SU-F-T-15: Evaluation of 192Ir, 60Co and 169Yb Sources for High Dose Rate Prostate Brachytherapy Inverse Planning Using An Interior Point Constraint Generation Algorithm

    Energy Technology Data Exchange (ETDEWEB)

    Mok Tsze Chung, E; Aleman, D [University of Toronto, Toronto, Ontario (Canada); Safigholi, H; Nicolae, A; Davidson, M; Ravi, A; Song, W [Odette Cancer Centre, Sunnybrook Health Sciences Centre, Toronto, Ontario (Canada)

    2016-06-15

    Purpose: The effectiveness of using a combination of three sources, {sup 60}Co, {sup 192}Ir and {sup 169}Yb, is analyzed. Different combinations are compared against a single {sup 192}Ir source on prostate cancer cases. A novel inverse planning interior point algorithm is developed in-house to generate the treatment plans. Methods: Thirteen prostate cancer patients are separated into two groups: Group A includes eight patients with the prostate as target volume, while group B consists of four patients with a boost nodule inside the prostate that is assigned 150% of the prescription dose. The mean target volume is 35.7±9.3cc and 30.6±8.5cc for groups A and B, respectively. All patients are treated with each source individually, then with paired sources, and finally with all three sources. To compare the results, boost volume V150 and D90, urethra Dmax and D10, and rectum Dmax and V80 are evaluated. For fair comparison, all plans are normalized to a uniform V100=100. Results: Overall, double- and triple-source plans were better than single-source plans. The triple-source plans resulted in an average decrease of 21.7% and 1.5% in urethra Dmax and D10, respectively, and 8.0% and 0.8% in rectum Dmax and V80, respectively, for group A. For group B, boost volume V150 and D90 increased by 4.7% and 3.0%, respectively, while keeping similar dose delivered to the urethra and rectum. {sup 60}Co and {sup 192}Ir produced better plans than their counterparts in the double-source category, whereas {sup 60}Co produced more favorable results than the remaining individual sources. Conclusion: This study demonstrates the potential advantage of using a combination of two or three sources, reflected in dose reduction to organs-at-risk and more conformal dose to the target. three sources, reflected in dose reduction to organs-at-risk and more conformal dose to the target. Our results show that {sup 60}Co, {sup 192}Ir and {sup 169}Yb produce the best plans when used simultaneously and

  9. Cobalt toxicity: Chemical and radiological combined effects on HaCaT keratinocyte cell line

    International Nuclear Information System (INIS)

    Sandre, C.; Moulin, C.; Bresson, C.; Gault, N.; Poncy, J. L.; Lefaix, J. L.

    2010-01-01

    Cobalt (Co) is an essential trace element well known as a constituent of vitamin B 12 , but different compounds of Co are also described as highly toxic and/or radio-toxic for individuals or the environment. In nuclear power plants, 58 Co and 60 Co are radioactive isotopes of cobalt present as activation products of stable Co and Ni used in alloys. Skin exposure is a current occupational risk in the hard metal and nuclear industries. As biochemical and molecular cobalt-induced toxicological mechanisms are not fully identified, we investigated cobalt toxicity in a model human keratinocyte cell line, HaCaT. In this study, we propose a model to determine the in vitro chemical impact on cell viability of a soluble form of cobalt (CoCl 2 ) with or without gamma-ray doses to mimic contamination by 60 Co, to elucidate the mechanisms of cobalt intracellular chemical and radiological toxicity. Intracellular cobalt concentration was determined after HaCaT cell contamination and chemical toxicity was evaluated in terms of cellular viability and clonogenic survival. We investigated damage to DNA in HaCaT cells by combined treatment with chemical cobalt and a moderate gamma-ray dose. Additive effects of cobalt and irradiation were demonstrated. The underlying mechanism of cobalt toxicity is not clearly established, but our results seem to indicate that the toxicity of Co(II) and of irradiation arises from production of reactive oxygen species. (authors)

  10. Cobalt toxicity: Chemical and radiological combined effects on HaCaT keratinocyte cell line

    Energy Technology Data Exchange (ETDEWEB)

    Gault, N. [CEA Fontenay aux Roses, DSV/IRCM/SCSR/LRTS, 92265 Fontenay aux Rose (France); Sandre, C.; Moulin, B.; Bresson, C. [CEA, DEN, SECR, Laboratoire de Speciation des Radionucleides et des Molecules, F-91191 Gif-sur-Yvette (France); Poncy, J.L. [CEA Bruyeres Le Chatel, DSV/IRCM/SREIT/LRT, 91680 Bruyeres Le Chatel (France); Lefaix, J.L. [CEA Caen, DSV/IRCM/SRO/LARIA, 14070 Caen (France)

    2010-07-01

    Cobalt (Co) is an essential trace element well known as a constituent of vitamin B12, but different compounds of Co are also described as highly toxic and/or radio-toxic for individuals or the environment. In nuclear power plants, {sup 58}Co and {sup 60}Co are radioactive isotopes of cobalt present as activation products of stable Co and Ni used in alloys. Skin exposure is a current occupational risk in the hard metal and nuclear industries. As biochemical and molecular cobalt-induced toxicological mechanisms are not fully identified, we investigated cobalt toxicity in a model human keratinocyte cell line, HaCaT. In this study, we propose a model to determine the in vitro chemical impact on cell viability of a soluble form of cobalt (CoCl{sub 2}) with or without {gamma}-ray doses to mimic contamination by {sup 60}Co, to elucidate the mechanisms of cobalt intracellular chemical and radiological toxicity. Intracellular cobalt concentration was determined after HaCaT cell contamination and chemical toxicity was evaluated in terms of cellular viability and clonogenic survival. We investigated damage to DNA in HaCaT cells by combined treatment with chemical cobalt and a moderate {gamma}-ray dose. Additive effects of cobalt and irradiation were demonstrated. The underlying mechanism of cobalt toxicity is not clearly established, but our results seem to indicate that the toxicity of Co(II) and of irradiation arises from production of reactive oxygen species. (authors)

  11. Cobalt toxicity: Chemical and radiological combined effects on HaCaT keratinocyte cell line

    Energy Technology Data Exchange (ETDEWEB)

    Sandre, C.; Moulin, C.; Bresson, C. [CEA Saclay, DEN, SECR, Lab Speciat Radionucleides and Mol, F-91191 Gif Sur Yvette (France); Gault, N. [CEA Fontenay Roses, DSV IRCM SCSR LRTS, F-92265 Fontenay Aux Roses (France); Poncy, J. L. [CEA Bruyeres Le Chatel, DSV IRCM SREIT LRT, F-91680 Bruyeres Le Chatel (France); Lefaix, J. L. [CEA Caen, DSV IRCM SRO LARIA, F-14070 Caen (France)

    2010-07-01

    Cobalt (Co) is an essential trace element well known as a constituent of vitamin B{sub 12}, but different compounds of Co are also described as highly toxic and/or radio-toxic for individuals or the environment. In nuclear power plants, {sup 58}Co and {sup 60}Co are radioactive isotopes of cobalt present as activation products of stable Co and Ni used in alloys. Skin exposure is a current occupational risk in the hard metal and nuclear industries. As biochemical and molecular cobalt-induced toxicological mechanisms are not fully identified, we investigated cobalt toxicity in a model human keratinocyte cell line, HaCaT. In this study, we propose a model to determine the in vitro chemical impact on cell viability of a soluble form of cobalt (CoCl{sub 2}) with or without gamma-ray doses to mimic contamination by {sup 60}Co, to elucidate the mechanisms of cobalt intracellular chemical and radiological toxicity. Intracellular cobalt concentration was determined after HaCaT cell contamination and chemical toxicity was evaluated in terms of cellular viability and clonogenic survival. We investigated damage to DNA in HaCaT cells by combined treatment with chemical cobalt and a moderate gamma-ray dose. Additive effects of cobalt and irradiation were demonstrated. The underlying mechanism of cobalt toxicity is not clearly established, but our results seem to indicate that the toxicity of Co(II) and of irradiation arises from production of reactive oxygen species. (authors)

  12. Modeling the contribution of point sources and non-point sources to Thachin River water pollution.

    Science.gov (United States)

    Schaffner, Monika; Bader, Hans-Peter; Scheidegger, Ruth

    2009-08-15

    Major rivers in developing and emerging countries suffer increasingly of severe degradation of water quality. The current study uses a mathematical Material Flow Analysis (MMFA) as a complementary approach to address the degradation of river water quality due to nutrient pollution in the Thachin River Basin in Central Thailand. This paper gives an overview of the origins and flow paths of the various point- and non-point pollution sources in the Thachin River Basin (in terms of nitrogen and phosphorus) and quantifies their relative importance within the system. The key parameters influencing the main nutrient flows are determined and possible mitigation measures discussed. The results show that aquaculture (as a point source) and rice farming (as a non-point source) are the key nutrient sources in the Thachin River Basin. Other point sources such as pig farms, households and industries, which were previously cited as the most relevant pollution sources in terms of organic pollution, play less significant roles in comparison. This order of importance shifts when considering the model results for the provincial level. Crosschecks with secondary data and field studies confirm the plausibility of our simulations. Specific nutrient loads for the pollution sources are derived; these can be used for a first broad quantification of nutrient pollution in comparable river basins. Based on an identification of the sensitive model parameters, possible mitigation scenarios are determined and their potential to reduce the nutrient load evaluated. A comparison of simulated nutrient loads with measured nutrient concentrations shows that nutrient retention in the river system may be significant. Sedimentation in the slow flowing surface water network as well as nitrogen emission to the air from the warm oxygen deficient waters are certainly partly responsible, but also wetlands along the river banks could play an important role as nutrient sinks.

  13. Perturbation of cobalt 60 radiation doses by metal objects implanted during oral and maxillofacial surgery

    International Nuclear Information System (INIS)

    Tatcher, M.; Kuten, A.; Helman, J.; Laufer, D.

    1984-01-01

    The influence on cobalt 60 dose distributions of typical metal parts used in oral and maxillofacial surgery was studied. Relative doses were determined by exposing x-ray films in a polystyrene phantom set-up containing samples of vitallium, titanium, and stainless steel. Optical densities were converted to doses with the aid of sensitometric curves. The results show that for normal incidence there is a 25% to 40% increase in dose at the entrance side of the metal and a 20% to 25% decrease in dose at the exit side. The enhancement effect falls off rapidly and becomes negligible at about 1 mm from the interface. The reduction effect decreases more gradually and is still evident at distances of a few centimeters. These dose perturbations should be taken into account in the planning of radiation therapy for patients in whom metal objects have been implanted

  14. Extension of the Commonwealth standard of absorbed dose from cobalt-60 energy to 25 MV

    International Nuclear Information System (INIS)

    Sherlock, S.L.

    1986-01-01

    With the introduction of high energy linear accelerators in hospitals, there is a need for direct measurement of absorbed dose for energies to 25 MV for photons and 20 MeV electrons. The present Australian standard for absorbed dose at cobalt-60 energy is a graphite micro-calorimeter maintained at the AAEC Lucas Heights Research Laboratories. A thorough theoretical analysis of calorimeter operation suggests that computer control and monitoring techniques are appropriate. Solution of Newton's law of cooling for a four-body calorimeter allows development of a computer simulation model. Different temperature control algorithms may then be run and assessed using this model. In particular, the application of a simple differencer is examined. Successful implementation of the calorimeter for energies up to 25 MV could lead to the introduction of an Australian absorbed dose protocol based on calorimetry, therby reducing the uncertainties associated with exposure-based protocols

  15. 40 CFR 421.315 - Pretreatment standards for existing sources.

    Science.gov (United States)

    2010-07-01

    ...) EFFLUENT GUIDELINES AND STANDARDS NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY Secondary Tungsten....346 68.543 Tungsten 197.1 87.8 (k) Cobalt hydroxide filter cake wash. PSES for the Secondary Tungsten...

  16. Uptake of cobalt-60 from sea water and from labelled food by the common shrimp Crangon erangon (L.)

    International Nuclear Information System (INIS)

    Weers, A.W. van

    1975-01-01

    The role of two different modes of uptake in the accumulation of 60 Co by the common shrimp (Crangon crangon (L.)) is the subject of the present study. The results show that accumulation of 60 Co from sea water is a slow process. The concentration factor for whole animals reached in one month was only about 13. Most of the activity accumulated from water appears to be associated with the exoskeleton. As a consequence, moulting has a pronounced effect on the uptake pattern of 60 Co and on the subsequent retention of the radionuclide by shrimps kept in non-radioactive sea water. After single feeding of shrimps with labelled mussel flesh, 60 Co is retained according to an exponential function with a short-lived and a long-lived component. The short-lived component has a mean biological half-life of 1.2 days and accounts for about 80% of the initial activity. About 20% of the initial activity is lost with a mean biological half-life of about 10 days. After repeated feeding of labelled mussel flesh the short-lived component in the 60 Co retention is virtually absent. Cobalt-60 taken up with food is localized mainly in the digestive gland and the concentration in the edible muscles from the abdomen is relatively small. It is concluded from the present study that direct uptake from sea water will play only a minor role in the accumulation of 60 Co in the internal organs of the shrimp. 60 Co released into the marine environment will be taken up by shrimps mainly from food. The results indicate a rapid turnover of 60 Co in shrimps. (author)

  17. Estimation of uranium and cobalt-60 distribution coefficients and uranium-235 enrichment at the Combustion Engineering Company site in Windsor, Connecticut

    International Nuclear Information System (INIS)

    Wang, Y.; Orlandini, K.A.; Yu, C.

    1996-05-01

    Site-specific distribution coefficients for uranium isotopes and cobalt-60 (Co-60) and the fraction of uranium-235 (U-235) enrichment by mass were estimated for environmental samples collected from the Combustion Engineering Company site in Windsor, CT. This site has been identified for remedial action under the US Department of Energy's (DOE) Formerly Utilized Sites Remedial Action Program. The authority of DOE at the Combustion Engineering site is limited to (1) Building 3; (2) other activities or areas associated exclusively with Building 3 (such as sewer lines); or (3) contamination that is exclusively highly enriched uranium. In this study, 16 samples were collected from the Combustion Engineering site, including 8 soil, 4 sediment, 3 water, and 1 water plus sludge sample. These samples were analyzed for isotopic uranium by alpha spectrometry and for Co-60 by gamma spectrometry. The site-specific distribution coefficient for each isotope was estimated as the ratio of extractable radionuclide activity in the solid phase to the activity in the contact solution following a 19-day equilibration. The uranium activity measurements indicate that uranium-234 (U-234) and uranium-238 (U-238) were in secular equilibrium in two soil samples and that soil and sediment samples collected from other sampling locations had higher U-234 activity than U-238 activity in both the solid and solution phases. The site-specific distribution coefficient (Kd) ranged from 82 to 44,600 mL/g for U-238 and from 102 to 65,900 mL/g for U-234. Calculation of U-235 enrichment by mass indicated that four soil samples had values greater than 0.20; these values were 0.37, 0.38, 0.46, and 0.68. Cobalt-60 activity was detected in only three sediment samples. The measured Co-60 activity in the solid phase ranged from 0.15 to 0.45 pCi/g and that in the water phase of all three samples combined was 4 pCi/L. The Kd value for Co-60 in the site brook sediment was calculated to be 70 mL/g

  18. Prototype ion source for JT-60 neutral beam injectors

    International Nuclear Information System (INIS)

    Akiba, M.

    1981-01-01

    A prototype ion source for JT-60 neutral beam injectors has been fabricated and tested. Here, we review the construction of the prototype ion source and report the experimental results about the source characteristics that has been obtained at this time. The prototype ion source is now installed at the prototype unit of JT-60 neutral beam injection units and the demonstration of the performances of the ion source and the prototype unit has just started

  19. Source splitting via the point source method

    International Nuclear Information System (INIS)

    Potthast, Roland; Fazi, Filippo M; Nelson, Philip A

    2010-01-01

    We introduce a new algorithm for source identification and field splitting based on the point source method (Potthast 1998 A point-source method for inverse acoustic and electromagnetic obstacle scattering problems IMA J. Appl. Math. 61 119–40, Potthast R 1996 A fast new method to solve inverse scattering problems Inverse Problems 12 731–42). The task is to separate the sound fields u j , j = 1, ..., n of n element of N sound sources supported in different bounded domains G 1 , ..., G n in R 3 from measurements of the field on some microphone array—mathematically speaking from the knowledge of the sum of the fields u = u 1 + ... + u n on some open subset Λ of a plane. The main idea of the scheme is to calculate filter functions g 1 ,…, g n , n element of N, to construct u l for l = 1, ..., n from u| Λ in the form u l (x) = ∫ Λ g l,x (y)u(y)ds(y), l=1,... n. (1) We will provide the complete mathematical theory for the field splitting via the point source method. In particular, we describe uniqueness, solvability of the problem and convergence and stability of the algorithm. In the second part we describe the practical realization of the splitting for real data measurements carried out at the Institute for Sound and Vibration Research at Southampton, UK. A practical demonstration of the original recording and the splitting results for real data is available online

  20. Analysis of Gafchromic EBT3 film calibration irradiated with gamma rays from different systems: Gamma Knife and Cobalt-60 unit.

    Science.gov (United States)

    Najafi, Mohsen; Geraily, Ghazale; Shirazi, Alireza; Esfahani, Mahbod; Teimouri, Javad

    2017-01-01

    In recent years, Gafchromic films are used as an advanced instrument for dosimetry systems. The EBT3 films are a new generation of Gafchromic films. Our main interest is to compare the response of the EBT3 films exposed to gamma rays provided by the Theratron 780C as a conventional radiotherapy system and the Leksell Gamma Knife as a stereotactic radiotherapy system (SRS). Both systems use Cobalt-60 sources, thus using the same energy. However, other factors such as source-to-axis distance, number of sources, dose rate, direction of irradiation, shape of phantom, the field shape of radiation, and different scatter contribution may influence the calibration curve. Calibration curves for the 2 systems were measured and plotted for doses ranging from 0 to 40 Gy at the red and green channels. The best fitting curve was obtained with the Levenberg-Marquardt algorithm. Also, the component of dose uncertainty was obtained for any calibration curve. With the best fitting curve for the EBT3 films, we can use the calibration curve to measure the absolute dose in radiation therapy. Although there is a small deviation between the 2 curves, the p-value at any channel shows no significant difference between the 2 calibration curves. Therefore, the calibration curve for each system can be the same because of minor differences. The results show that with the best fitting curve from measured data, while considering the measurement uncertainties related to them, the EBT3 calibration curve can be used to measure the unknown dose both in SRS and in conventional radiotherapy. Copyright © 2017. Published by Elsevier Inc.

  1. Review of the {sup 60}Co Source. Development Program at Brookhaven National Laboratory; Le Programme de Mise au Point des Sources au {sup 60}Co au Laboratoire National de Brookhaven; Obzor programmy po razrabotke istochnikov {sup 60}Co v brukkhejvenskoj natsional'noj laboratorii; El Programa de Preparacion de Fuentes de {sup 60}Co del Laboratorio Nacional de Brookhaven

    Energy Technology Data Exchange (ETDEWEB)

    Kuhl, O. A. [Brookhaven National Laboratory, Upton, NY (United States)

    1966-11-15

    Early in the 1950's, at the request of the United States Atomic Energy Commission, Brookhaven National Laboratory (BNL) undertook the development of radiation sources. These sources were mainly of two types: large tubes, and flat strips. Initially these were used for research at BNL. Later, other institutions were permitted to use the irradiation facilities designed for these sources. As interest grew, source-irradiator combinations were made available to other researchers. Shipping containers for sources were developed. Small hot cells and water-filled pools were constructed to utilize the sources. Methods of dosimetry, curie evaluation, and irradiator design for these sources are discussed in this paper. During the research stages, economics were not usually important; however, the trend toward large- scale radiation processing in the field of food, chemicals and medical supplies will require careful consideration of the technical and economic aspects of source design. The development of the BNL Standard Mark I and Mark II Sources, already in use in a number of' facilities, is to satisfy these important requirements. The Mark I and Mark II sources are interchangeable. An improvement in the Mark II element design is that the inner cladding is metallurgically bonded to the cobalt core. It is now possible, for the first time, to reactivate these source elements after a period of use. Individual strips are sized for easy arrangement in plaques of various dimensions and shapes. The design philosophy, fabrication techniques, and test procedures, together with source analysis and curie evaluation, are described. Comparisons are made with other source types currently in use and economical and technical advantages are discussed. (author) [French] A la demande de la Commission de l'energie atomique des Etats-Unis, le Laboratoire national de Brookhaven a entrepris des les annees 50 la mise au point de sources de rayonnement. Ces sources etaient principalement de deux types

  2. Effects of gamma radiation from Cobalt 60 on eggs and adults of Sitotroga cerealella (Oliver, 1819) (Lepidoptera, Gelechiidae) in laboratory

    International Nuclear Information System (INIS)

    Rodrigues, Z.A.; Rego, A.M.; Oliveira, M.L. de; Ferreira, D.

    1983-01-01

    Lethal and sterilizing dosages from Cobalt-60 radiations were determined for Sitotroga cerealella (Oliver, 1819) eggs and adults. Eggs at the age of 0 to 24 hours were irradiated with dosages of 0,1,2; 4,6,8,10 and 12 krad; it was observed that 10 krad killed all embryos although this was not observed in 96 hours old eggs. A new group was irradiated with dosages of 0,60,80,100,120 and 140 krad, and complete lethal dosage was determined as 140 krad. Mating of irradiated with non irradiated insects resulted in 100% infertile eggs when either the males or females had received the dosage of 100 krad. Imediate lethality of S. cerealella adults was not observed with the dosages of 300 to 320 krad but all insects died after two days (L sup(D) 100/ 2 ). (Author) [pt

  3. Evaluation of leakage in cobalt-60 unit in National Cancer Institute (NCI) Wad Medani

    International Nuclear Information System (INIS)

    Fadlellah, R. A.

    2013-08-01

    This study has been conducted primarily to evaluate the leakages radiation in cobalt-60 unit in National Cancer Institute Wad Medani, which represent the basic risky factor in this unit for the radio therapists who spend much time during patient set up, also they need to stand near the head of the machine to fix some accessories. The measurements which done using survey meter give normal level of occupational exposure compared with IAEA references except one situation that the radio therapist to be close contact to the head of unit for long time which may increase the received dose, in this situation. The radio therapist either not well trained, or there is insufficient accessories to reduce the time inside the room. Radiotherapy department need a special considerations from the beginning of construction till starting of treatment. It is important to contain separate rooms, for planning to determine treatment area, another one for molding to shape lead blocks to protect normal parts and an optimum designed room for treatment to enable workers to apply basic radiation protection principles. (Author)

  4. Design and tests of a package for the transport of radioactive sources; Projeto e testes de uma embalagem para o transporte de fontes radioativas

    Energy Technology Data Exchange (ETDEWEB)

    Santos, Paulo de Oliveira, E-mail: pos@cdtn.b [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil)

    2011-10-26

    The Type A package was designed for transportation of seven cobalt-60 sources with total activity of 1 GBq. The shield thickness to accomplish the dose rate and the transport index established by the radioactive transport regulation was calculated by the code MCNP (Monte Carlo N-Particle Transport Code Version 5). The sealed cobalt-60 sources were tested for leakages. according to the regulation ISO 9978:1992 (E). The package was tested according to regulation Radioactive Material Transport CNEN. The leakage tests results pf the sources, and the package tests demonstrate that the transport can be safe performed from the CDTN to the steelmaking industries

  5. Change in the radiation dose at a point where an inhomogeneity partly covers the radiation field from a 60Co-γ-source

    International Nuclear Information System (INIS)

    Helmrot, E.

    1976-04-01

    Measurements and calculations have been made in order to study the change of the radiation dose in a point when an inhomogeneity covers parts of the radiation field from a Co 60-source. An ionization chamber, placed in a water phantom, was used for the measurements. As inhomogeneity an air cavity was used. The measuring point was placed on the central axis of the radiation field during the measurement. The air cavity was moved in front of the measuring point 0.5 - 1 cm by steps laterally, i.e. along a line perpendicular to the radiation direction. Measurements were made at different depths behind the air cavity. The air cavity was placed at different distances from the front plate of the water phantom. Measurements and calculations show that the change of the radiation dose, when the edge of the air cavity passes the measuring point, varies with the depth distance to the air cavity. The greatest deviation is near the air cavity and at a great distance behind this. The change of the radiation dose is less than 2 percent at distances greater than 2 cm from the edge of the air cavity laterally. This change is independent of the depth distance to the air cavity. The maximum deviation 1 cm from the edge of the air cavity is 5 percent independent of the distance tothe air cavity. Used methods of calculation can be extended to be used for irregular inhomogeneities but this requires knowledge of the three-dimensional extension of the inhomogeneity. (M.S.)

  6. Point Pollution Sources Dimensioning

    Directory of Open Access Journals (Sweden)

    Georgeta CUCULEANU

    2011-06-01

    Full Text Available In this paper a method for determining the main physical characteristics of the point pollution sources is presented. It can be used to find the main physical characteristics of them. The main physical characteristics of these sources are top inside source diameter and physical height. The top inside source diameter is calculated from gas flow-rate. For reckoning the physical height of the source one takes into account the relation given by the proportionality factor, defined as ratio between the plume rise and physical height of the source. The plume rise depends on the gas exit velocity and gas temperature. That relation is necessary for diminishing the environmental pollution when the production capacity of the plant varies, in comparison with the nominal one.

  7. Reconstruction of exposures to the public from a cobalt-60 irradiator facility

    International Nuclear Information System (INIS)

    Chapman, T.E.; Scherpelz, R.I.

    1992-01-01

    A study was performed for the US Department of Energy (DOE) to assess the radiation exposure received by the public from the operation of a cobalt-60 irradiator facility. Located south of Davis, California, at the former Laboratory for Energy-Related Health Research, the facility was an indoor-outdoor gamma irradiator operated for the DOE by the University of California, Davis. From 1970 to 1985, outdoor radiation exposure experiments conducted at the facility resulted in environmental radiation doses of 80 to 120 mSv per year along the facility's perimeter fence. Comprehensive environmental monitoring was not performed in the adjacent, uncontrolled areas and personnel who occupied these areas were not routinely monitored for radiation exposure. Because of incomplete environmental monitoring data, computer modeling was required to reconstruct the environmental dose rates present when the facility was in operation. Personnel occupancy times for the adjacent areas were determined from population statistics, historical records, and personal interviews. The potential dose equivalents calculated for the individuals who lived or worked in neighboring areas ranged from 0.02 to 3.6 mSv per year. These exposures, some of which exceed the current DOE standard of 1 mSv/y, were less than the DOE regulatory limit of 5 mSv/y for exposure to the public that was in effect when the facility was in operation

  8. Depth determination of buried caesium-137 and cobalt-60 sources using scatter peak data

    International Nuclear Information System (INIS)

    Adams, J. C.; Joyce, M. J.; Mellor, M.

    2009-01-01

    An investigation into an alternative approach to 3D (3-dimensional) source mapping is proposed, by combining the insights of two existing techniques. The first of these is a 3D 'imaging' tool, N-Visage TM that has been developed by REACT Engineering Ltd. This technique is efficient and robust, but is not a true 3D technique as it relies on user-supplied 2D (2-dimensional) manifolds to constrain source locations. The second technique uses the γ-photopeak and an X-ray peak to determine radionuclide source depth using a relative attenuation method. We look at the possibility of combining both techniques to constrain both the location and depth of a radiological source buried under shielding. It is believed a combined method using spectra recorded above the shielding object will be of use in the nuclear decommissioning and land contamination industries. N-Visage TM has previously been used to map source distributions of mixed radionuclides with complex geometries through shielding media. The software works by producing a computer model which recreates the experimental setup. A survey is imported, comprising a set of γ-spectra recorded with an instrument of known efficiency and isotropy taken at a variety of locations around the area of interest. A survey plan recording the location and orientation of the instrument for each reading is also reconstructed. N-Visage TM is then able to determine the locations of the source(s) without prior knowledge of exactly where they are located, by building and inverting a simple physical model relating potential source locations to the recorded spectra. This research sets out to investigate the possibility of combining the geometric insights of N-Visage TM with a method of extracting depth information from scatter data, rather than the X-ray peak. By combining the γ-photopeak and scatter areas of a spectrum, the thickness of the shielding media between source and detector can potentially be inferred. Using scattered photons rather

  9. Separation of cobalt from synthetic intermediate and decontamination radioactive wastes using polyurethane foam

    International Nuclear Information System (INIS)

    Rao, S.V.S.; Lal, K.B.; Narasimhan, S.V.; Ahmed, J.

    1997-01-01

    Studies have been carried out on the removal of radioactive cobalt ( 60 Co) from synthetic intermediate level waste (ILW) and decontamination waste using neat polyurethane (PU) foam as well as n-tributyl phosphate-polyurethane (TBP-PU) foam. The radioactive cobalt has been extracted on the PU foam as cobalt thiocyanate from the ILW. Maximum removal of cobalt has been observed when the concentration of thiocyanate in the solution is about 0.4 M. Cobalt can be separated from decontamination waste containing ethylenediaminetetraacetic acid (EDTA) and iron(II). The extent of extraction of cobalt is slow and the separation of iron and cobalt is better with the neat PU foam compared to the TBP-PU foam. The presence of iron in the decontamination waste facilitates the extraction of cobalt thiocyanate on the PU foam. Column studies have been carried out in order to extend these studies to the plant scale. The capacities of the PU foams for cobalt have been determined. The effect of density and the surface area of PU foam have been investigated. Fourier Transform Infrared (FT-IR) spectral studies have been conducted to find out the interaction between PU foam and cobalt thiocyanate species

  10. Preliminary studies of cobalt complexation in groundwater

    International Nuclear Information System (INIS)

    Warwick, P.; Shaw, P.; Williams, G.M.; Hooker, P.J.

    1988-01-01

    A relatively non-invasive method has been used to separate complexed from free cobalt-60 in groundwater, using the weak cationic adsorption properties of Sephadex gels, and a mobile phase of natural groundwater. Results show the kinetics of Co complex formation in groundwater to be slow, and that the equilibrium position is affected by temperature, cobalt concentration and the ionic/organic strength of the groundwater. The addition of DAEA cellulose to the groundwater to remove humic material, also removed the majority of organic species which absorb UV at 254 nm, but 45% of the original total organic carbon remained, and the amount of complexed cobalt left in solution was only reduced to 76% of its former concentration. This suggests that the completed Co species separated by the method described in this paper are a mixture of inorganic and organic compounds, and studies are therefore continuing to establish their exact nature. (author)

  11. Preliminary studies of cobalt complexation in groundwater

    International Nuclear Information System (INIS)

    Warwick, P.; Shaw, P.; Williams, G.M.; Hooker, P.J.

    1988-01-01

    A relatively non-invasive method has been used to separate complexed from free cobalt-60 in groundwater, using the weak cationic adsorption properties of Sephadex gels, and a mobile phase of natural groundwater. Results show the kinetics of Co complex formation in groundwater to be slow, and that the equilibrium position is affected by temperature, cobalt concentration and the ionic/organic strength of the groundwater. The addition of DEAE cellulose to the groundwater to remove humic material, also removed the majority of organic species with absorb UV at 254 nm, but 45% of the original total organic carbon remained, and the amount of complexed cobalt left in solution was only reduced to 76% of its former concentration. This suggests that the complexed Co species separated by the method described in this paper are a mixture of inorganic and organic compounds, and studies are therefore continuing to establish their exact nature. (orig.)

  12. Hematological changes in sheep inoculated with natural and Cobalt60-irradiated Crotalus durissus terrificus venom (Laurenti, 1768

    Directory of Open Access Journals (Sweden)

    D. P. Netto

    2004-01-01

    Full Text Available Natural (NV and Cobalto60-irradiated (IrV Crotalus durissus terrificus venom were used to evaluate serum production capacity of sheep and possible hematological and biochemical effects. Freeze-dried venom aliquots were diluted in acidified saline solution (NaCl 150 mM, pH 3.0 and irradiated by a Cobalt 60 source at a dose of 5.54 x 102 Gy/h and a concentration of 2.000 Gy. Twelve sheep were divided into two groups of six animals. One group received irradiated venom (IrV and the other natural venom (NV. Three antigen doses (venom were administered at monthly intervals. Blood samples were collected weekly for analysis of serum neutralization potency and capacity, complete blood count (CBC, total plasma protein, fibrinogen, albumin, and globulin. At the end of the experiment, the animals were challenged with a LD50 for sheep and showed no signs of envenoming. The two groups did not present clinical alterations. Results of the total leukocyte count did not present interaction or time factor effect for both groups, but there was a different action between them, with the NV group presenting more cells than the IrV group. The leukocyte increase to 13,000/ml indicates that slight leukocytosis occurred in the week after the first inoculation in the NV group. There was no statistically significant difference between groups in the absolute count of segmented neutrophils, eosinophils, and lymphocytes but there were statistically significant oscillations in values at the different collecting times. The NV group presented an increase in the absolute neutrophil count after the first inoculation that persisted for 5 weeks. In the IrV group, the increase in neutrophils occurred only in the first week returning to normal in the following weeks. The alterations in the neutrophil count are indicative of systemic inflammatory response related to cytokine release; response was more marked in the NV group, showing its greater toxicity.

  13. Savannah River Laboratory isotopic power and heat sources. Monthly report, June 1966

    International Nuclear Information System (INIS)

    1966-06-01

    Progress in research and development is described for the following: preparation of Tm 2 O 3 ; properties of thulium-171; reduction of Pu-236 in Pu-238; 238 Pu oxide with low neutron emission; and encapsulation of cobalt-60 heat sources

  14. Aspect of sucrose and its monomers from sugarcane juice submitted to different doses of cobalt-60 irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Lima, Roberta B.; Rela, Paulo [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil); Arthur, Valter, E-mail: arthur@cena.usp.br [Centro de Energia Nuclear da Agricultura (CENA/USP), Piracicaba, SP (Brazil). Dept. de Radiobiologia e Ambiente; Souza, Juliana Ap.; Prezotto, Mariane P.; Baptista, Antonio S.; Aguiar, Claudio L., E-mail: claguiar@esalq.usp.br [Escola Superior de Agricultura Luiz de Queiroz (ESALQ/USP), Piracicaba, SP, (Brazil). Dept. de Agroindustria, Alimentos e Nutricao

    2011-07-01

    The sugarcane is an important source of sucrose, which has been for years an essential source of energy, even for consumption as food or to produce liquid fuels. During the manufacturing process of crystal sugar, one of the main concerns is to avoid the inversion of sucrose to glucose and fructose, which could decrease the efficiency of crystal's production. The increase of sugar production and the growing interest of foreign market have encouraged the development of numerous investigative studying, searching for alternative technologies and a better efficiency of process of current clarifying, sulphitation, producing a whiter sugar in a process named 'sulfur free' with effectiveness production of crystal sucrose. In acid conditions or extended exposure to high temperatures, inversion reaction can occur, resulting in the formation of reducing sugars - i.e. mainly glucose and fructose - which affect the sucrose crystallization process. This study aimed to evaluate the impact of gamma irradiation (Co-60) on the rate of reducing sugars and also totals reducing sugars (i.e., sucrose, glucose and fructose) into sugarcane juice before and after treatment with different doses: 5, 10 and 20 kGy. Some parameters were evaluated, such as: Brix, pH, reducing sugar and total reducing sugar, and from the results it was observed that parameters such as Brix and pH did not have a significant variation between the control and irradiated samples, varying from 13.2 Brix (Control) to 13.0 Brix (20 kGy) and 5.26 (10KGy) to 5.36 (20 kGy), respectively. For the analysis of reducing sugar, the contents varying from 29 {+-}0.87 to 43{+-}1.43 mg.mL{sup -1} with the largest rise occurred in the sample irradiated at 20 kGy. For analysis of total reducing sugar, the results ranged from 12.02{+-}0.46% in control sample to 11.93{+-}0.21% in the sample which received the highest radiation dose, 20 kGy. Against these results, we could conclude that the impact of gamma radiation

  15. Aspect of sucrose and its monomers from sugarcane juice submitted to different doses of cobalt-60 irradiation

    International Nuclear Information System (INIS)

    Lima, Roberta B.; Rela, Paulo; Arthur, Valter; Souza, Juliana Ap.; Prezotto, Mariane P.; Baptista, Antonio S.; Aguiar, Claudio L.

    2011-01-01

    The sugarcane is an important source of sucrose, which has been for years an essential source of energy, even for consumption as food or to produce liquid fuels. During the manufacturing process of crystal sugar, one of the main concerns is to avoid the inversion of sucrose to glucose and fructose, which could decrease the efficiency of crystal's production. The increase of sugar production and the growing interest of foreign market have encouraged the development of numerous investigative studying, searching for alternative technologies and a better efficiency of process of current clarifying, sulphitation, producing a whiter sugar in a process named 'sulfur free' with effectiveness production of crystal sucrose. In acid conditions or extended exposure to high temperatures, inversion reaction can occur, resulting in the formation of reducing sugars - i.e. mainly glucose and fructose - which affect the sucrose crystallization process. This study aimed to evaluate the impact of gamma irradiation (Co-60) on the rate of reducing sugars and also totals reducing sugars (i.e., sucrose, glucose and fructose) into sugarcane juice before and after treatment with different doses: 5, 10 and 20 kGy. Some parameters were evaluated, such as: Brix, pH, reducing sugar and total reducing sugar, and from the results it was observed that parameters such as Brix and pH did not have a significant variation between the control and irradiated samples, varying from 13.2 Brix (Control) to 13.0 Brix (20 kGy) and 5.26 (10KGy) to 5.36 (20 kGy), respectively. For the analysis of reducing sugar, the contents varying from 29 ±0.87 to 43±1.43 mg.mL -1 with the largest rise occurred in the sample irradiated at 20 kGy. For analysis of total reducing sugar, the results ranged from 12.02±0.46% in control sample to 11.93±0.21% in the sample which received the highest radiation dose, 20 kGy. Against these results, we could conclude that the impact of gamma radiation emitted to dose rate of 3.88 KGy

  16. Radioactive waste management in sealed sources laboratory production

    International Nuclear Information System (INIS)

    Carvalho, Gilberto

    2001-01-01

    The laboratory of sealed sources production, of Instituto de Pesquisas Energeticas e Nucleares, was created in 1983 and since then, has produced radioactive sources for industry and engineering in general, having specialization in assembly of radiation sources for non destructive testings, by gammagraphy, with Iridium-192, that represents 98% of the production of laboratory and 2% with the Cobalt-60, used in nuclear gages. The aim of this work, is to quantify and qualify the radioactive wastes generated annually, taking into account, the average of radioactive sources produced, that are approximately 220 sources per year

  17. Research on point source simulating the γ-ray detection efficiencies of stander source

    International Nuclear Information System (INIS)

    Tian Zining; Jia Mingyan; Shen Maoquan; Yang Xiaoyan; Cheng Zhiwei

    2010-01-01

    For φ 75 mm x 25 mm sample, the full energy peak efficiencies on different heights of sample radius were obtained using the point sources, and the function parameters about the full energy peak efficiencies of point sources based on radius was fixed. The 59.54 keV γ-ray, 661.66 keV γ-ray, 1173.2 keV γ-ray, 1332.5 keV γ-ray detection efficiencies on different height of samples were obtained, based on the full energy peak efficiencies of point sources and its height, and the function parameters about the full energy peak efficiencies of surface sources based on sample height was fixed. The detection efficiency of (75 mm x 25 mm calibration source can be obtained by integrality, the detection efficiencies simulated by point sources are consistent with the results of stander source in 10%. Therefore, the calibration method of stander source can be substituted by the point source simulation method, and it tis feasible when there is no stander source.) (authors)

  18. Induced Temporal Signatures for Point-Source Detection

    International Nuclear Information System (INIS)

    Stephens, Daniel L.; Runkle, Robert C.; Carlson, Deborah K.; Peurrung, Anthony J.; Seifert, Allen; Wyatt, Cory R.

    2005-01-01

    Detection of radioactive point-sized sources is inherently divided into two regimes encompassing stationary and moving detectors. The two cases differ in their treatment of background radiation and its influence on detection sensitivity. In the stationary detector case the statistical fluctuation of the background determines the minimum detectable quantity. In the moving detector case the detector may be subjected to widely and irregularly varying background radiation, as a result of geographical and environmental variation. This significant systematic variation, in conjunction with the statistical variation of the background, requires a conservative threshold to be selected to yield the same false-positive rate as the stationary detection case. This results in lost detection sensitivity for real sources. This work focuses on a simple and practical modification of the detector geometry that increase point-source recognition via a distinctive temporal signature. A key part of this effort is the integrated development of both detector geometries that induce a highly distinctive signature for point sources and the development of statistical algorithms able to optimize detection of this signature amidst varying background. The identification of temporal signatures for point sources has been demonstrated and compared with the canonical method showing good results. This work demonstrates that temporal signatures are efficient at increasing point-source discrimination in a moving detector system

  19. Flux perturbation factor in cobalt samples for the reactor production of Co-60

    International Nuclear Information System (INIS)

    Curzio, O.A.

    1976-07-01

    Total flux perturbation factor (F) is experimentally determined for hollow cylinder cobalt samples irradiated in the RA-3 reactor. F factor is studied for different thicknesses of the material and the values are compared with those theoretically estimated by Dwork for a similar. (author) [es

  20. Enhancement of viability of radiosensitive (PBMC and resistant (MDA-MB-231 clones in low-dose-rate cobalt-60 radiation therapy

    Directory of Open Access Journals (Sweden)

    Patrícia Lima Falcão

    2015-06-01

    Full Text Available Abstract Objective: In the present study, the authors investigated the in vitro behavior of radio-resistant breast adenocarcinoma (MDA-MB-231 cells line and radiosensitive peripheral blood mononuclear cells (PBMC, as a function of different radiation doses, dose rates and postirradiation time kinetics, with a view to the interest of clinical radiotherapy. Materials and Methods: The cells were irradiated with Co-60, at 2 and 10 Gy and two different exposure rates, 339.56 cGy.min–1 and the other corresponding to one fourth of the standard dose rates, present over a 10-year period of cobalt therapy. Post-irradiation sampling was performed at pre-established kinetics of 24, 48 and 72 hours. The optical density response in viability assay was evaluated and a morphological analysis was performed. Results: Radiosensitive PBMC showed decrease in viability at 2 Gy, and a more significant decrease at 10 Gy for both dose rates. MDAMB- 231 cells presented viability decrease only at higher dose and dose rate. The results showed MDA-MB-231 clone expansion at low dose rate after 48–72 hours post-radiation. Conclusion: Low dose rate shows a possible potential clinical impact involving decrease in management of radio-resistant and radiosensitive tumor cell lines in cobalt therapy for breast cancer.

  1. Mobility and retention of Co-60 in soils in coastal areas

    International Nuclear Information System (INIS)

    Mahara, Y.; Kudo, A.

    1980-01-01

    The purpose of this study was to determine the mobility of radioactive cobalt ( 60 Co), a typical operating waste, in soils in coastal areas (where all Japanese commercial reactors are located). The results of this investigation may assist in evaluating a degree of safety for the future disposal of radioactive wastes underground. Freshwater and seawater were examined under both aerobic and anaerobic conditions by simulating the environmental conditions of the soils in coastal areas. More than 80% of 60 Co moves freely within soils covered by seawater under anaerobic conditions. Furthermore, the cobalt in the water phase can pass through a dialysis membrane with a pore size of 24 A. This indicates that the cobalt is either in ionic form or associated with materials of low molecular weight. On the other hand, more than 95% of 60 Co was retained by soils covered by freshwater under aerobic conditions. This cobalt, once fixed on soils, was not easily desorbed by seawater under anaerobic conditions. The results suggest that the mobility of cobalt disposed of underground is greatly enced by the initial environmental conditions in the soils in coastal areas. (H.K.)

  2. Effect of (/sup 60/cobalt) gamma rays on growth and root rot diseases in mungbean (vigna radiata L.)

    International Nuclear Information System (INIS)

    Ikram, N.; Dawar, S.; Zaki, M.J.; Abass, Z.

    2010-01-01

    Present investigation showed that gamma rays influences suppressive effect on root rot fungi such as Macrophomina phaseolina (Tassi) Goid, Rhizoctonia solani Kuhn and Fusarium spp., and inducive effect on growth parameters of mung bean (Vigna radiata L.). Seeds of mung bean were treated with gamma rays (/sup 60/Cobalt) at time periods of 0 and 4 minutes and stored for 90 days at room temperature to determine its effect on growth parameters and infection of root infecting fungi. All treatments of gamma rays enhanced the growth parameters as compared to untreated plants. Infection of M. phaseolina, R. solani and Fusarium spp., were significantly decreased on mung bean seeds treated with gamma rays. Gamma rays significantly increased the growth parameters and controlled the root rot fungi up to 90 days of storage of seeds. (author)

  3. Recovery of Cobalt as Cobalt Oxalate from Cobalt Tailings Using Moderately Thermophilic Bioleaching Technology and Selective Sequential Extraction

    Directory of Open Access Journals (Sweden)

    Guobao Chen

    2016-07-01

    Full Text Available Cobalt is a very important metal which is widely applied in various critical areas, however, it is difficult to recover cobalt from minerals since there is a lack of independent cobalt deposits in nature. This work is to provide a complete process to recover cobalt from cobalt tailings using the moderately thermophilic bioleaching technology and selective sequential extraction. It is found that 96.51% Co and 26.32% Cu were extracted after bioleaching for four days at 10% pulp density. The mean compositions of the leach solutions contain 0.98 g·L−1 of Co, 6.52 g·L−1 of Cu, and 24.57 g·L−1 of Fe (III. The copper ion was then recovered by a solvent extraction process and the ferric ions were selectively removed by applying a goethite deironization process. The technological conditions of the above purification procedures were deliberately discussed. Over 98.6% of copper and 99.9% of ferric ions were eliminated from the leaching liquor. Cobalt was finally produced as cobalt oxalate and its overall recovery during the whole process was greater than 95%. The present bioleaching process of cobalt is worth using for reference to deal with low-grade cobalt ores.

  4. Polytypic transformations during the thermal decomposition of cobalt hydroxide and cobalt hydroxynitrate

    International Nuclear Information System (INIS)

    Ramesh, Thimmasandra Narayan

    2010-01-01

    The isothermal decomposition of cobalt hydroxide and cobalt hydroxynitrate at different intervals of temperature leads to the formation of Co 3 O 4 . The phase evolution during the decomposition process was monitored using powder X-ray diffraction. The transformation of cobalt hydroxide to cobalt oxide occurs via three phase mixture while cobalt hydroxynitrate to cobalt oxide occurs through a two phase mixture. The nature of the sample and its preparation method controls the decomposition mechanism. The comparison of topotactical relationship between the precursors to the decomposed product has been reported in relation to polytypism. - Graphical abstract: Isothermal thermal decomposition studies of cobalt hydroxide and cobalt hydroxynitrate at different intervals of temperature show the metastable phase formed prior to Co 3 O 4 phase.

  5. Γ-source Neutral Point Clamped Inverter

    DEFF Research Database (Denmark)

    Mo, Wei; Loh, Poh Chiang; Blaabjerg, Frede

    Transformer based Z-source inverters are recently proposed to achieve promising buck-boost capability. They have improved higher buck-boost capability, smaller size and less components count over Z-source inverters. On the other hand, neutral point clamped inverters have less switching stress...... and better output performance comparing with traditional two-level inverters. Integrating these two types of configurations can help neutral point inverters achieve enhanced votlage buck-boost capability....

  6. Preoperative cobalt60 irradiation delays the healing of rectal anastomoses in rats

    International Nuclear Information System (INIS)

    Fang, C.B.; Klug, W.A.; Capelhuchnik, P.

    2005-01-01

    The healing of colorectal anastomoses after irradiation therapy continues to be a major concern. The authors evaluated the healing of rectal anastomoses in a rat model after a preoperative 500-c Gy dose of cobalt 60 irradiation. Thirty-six male Wistar rats were divided into two equal groups: control (group A), and irradiation group (group B). Group B received a single 500-c Gy dose of irradiation, and a rectal resection and end-to-end anastomosis was performed in both groups on the seventh day after irradiation. Parameters of the healing process included bursting pressure and collagen content on the fifth, seventh, and fourteenth days after surgery. In the irradiation group, the mean bursting pressure on the fifth, seventh, and fourteenth days was 116, 218, and 273 mmHg, respectively. The collagen content assessed by histomorphometry was 9.0, 20.8, and 32%, respectively. In contrast, the control group had a mean bursting pressure of 175, 225 and 263 mmHg, and a collagen content of 17.8, 28.1, and 32.1%, respectively. The adverse effect of irradiation on healing was detectable only on the fifth postoperative day, as demonstrated by lower bursting pressure (P < 0.013) and collagen content (P < 0.008). However, there was no failure of anastomotic healing such as leakage or dehiscence due to irradiation. We conclude that a single preoperative 500-c Gy dose of irradiation delays the healing of rectal anastomosis in rats. (author)

  7. Studi Standarisasi Radioterapi Cobalt-60 Terhadap Kuantitas Sel Darah Pada Penderita Kanker Serviks (Cancer Cervics Di Rsup Sanglah Denpasar

    Directory of Open Access Journals (Sweden)

    Retianingsih Oeta Ulan

    2017-09-01

    Full Text Available After doing research with Title Study of Cobalt-60 radiotherapy Standards Against Quantity Blood Cells In Patients with Cervical Cancer (Cancer Cervics at Sanglah Hospital in Denpasar. This study uses secondary data such as a complete blood from each patient with cervical cancer in 2015 that radiotherapy with fractionation method. The amount of patient data used in this study is 5 pieces. The quantity of blood cells that are analyzed include RBC, HGB, WBC and WBC Components (LY, EO, EO, BA, NE, MO. Fractionation dose is 800-5800cGy. The results of data analysis showed that each blood cell components are still within the range of 2-50%, so a method of radiotherapy is still fit for use.

  8. HEAVY METALS ABUNDANCE IN THE SOILS OF THE PANTELIMON – BRĂNEŞTI AREA, ILFOV COUNTY a CADMIUM, COBALT, CHROMIUM, COPPER

    Directory of Open Access Journals (Sweden)

    Radu Lacatusu

    2011-12-01

    Full Text Available More than 20 years later, a new research on heavy metals (cadmium, cobalt, chromium, copper contents in the soil cover of the Pantelimon – Brăneşti area located East of the Bucharest Municipality and exposed for several decades to the influence of industrial emissions from two non-ferrous metallurgy plants is presented. A 5,912.72 ha area was investigated, 544 samples taken by geometric horizons (0-20; 20-40; 40-60 cm from 215 points have been analyzed.The dominant soils are: Preluvosols, Chernozems, Phaeozems. The analytical data showed that all the heavy metals contents are below the maximum allowable limits and of the alarm thresholds. Higher cadmium and copper concentrations have been registered in the 40-60 cm layer and higher chromium and copper concentrations in the 0-20 cm layer. Cadmium and cobalt distributions are non-central, with a right asymmetry, and the chromium and copper ones are slightly symmetric. The surface distribution of the heavy metals shows the presence of some high contents areas distributed insularly, with a higher frequency around the industrial units. The geochemical abundance indexes are higher than 1 for cadmium and lower for cobalt, chromium, and copper, and the pedo-geochemical abundance indexes are lower than 1 only for chromium.

  9. Quarantine treatment in eggs of Stenoma catenifer Walsingham (Lepidoptera: Elachistidae), with gamma radiation of Cobalt-60

    International Nuclear Information System (INIS)

    Silva, L.K.F.; Arthur, V.; Nava, D.E.; Parra, J.R.P.

    2006-01-01

    The objective of this work has been to determine the lethal dose of gamma radiation of Cobalt-60 for the Stenoma catenifer eggs. For the irradiation of the eggs an irradiador Gammacell-220 (CO60) was utilized, (Rate dose: 1.054 kGY/h). The doses were: 0, 25, 50, 75, 100, 125 and 150 Gy, 90 eggs/dose (six repetitions). The number of caterpillars emerged was evaluated, and the survivors growed in seeds of avocado. The adults obtained were coupled with normal insects, growed in boxes with double face paper containing the food (10% honey) and a fruit of avocado. The experimental design was totally random, being the data submitted to the analysis of the varianza and the averages compared by the test of Tukey (P=5%). The emergence of caterpillars from the treated eggs with dose of 0, 25 and 50 Gy was verified. The dose of 50 Gy caused deformation in the caterpillars emerged. The effect of the gamma radiation in the viability of the eggs was proportional to the dose increase. The adults from the eggs dealt with 25 Gy presented non viabilty of 92,85 and 100% for male and female, respectively. A radiation gamma of 75 Gy is recommended for treatment quarantine for avocado fruits infested with of S. catenifer eggs

  10. Blood doping by cobalt. Should we measure cobalt in athletes?

    Directory of Open Access Journals (Sweden)

    Guidi Gian

    2006-07-01

    Full Text Available Abstract Background Blood doping is commonplace in competitive athletes who seek to enhance their aerobic performances through illicit techniques. Presentation of the hypothesis Cobalt, a naturally-occurring element with properties similar to those of iron and nickel, induces a marked and stable polycythemic response through a more efficient transcription of the erythropoietin gene. Testing the hypothesis Although little information is available so far on cobalt metabolism, reference value ranges or supplementation in athletes, there is emerging evidence that cobalt is used as a supplement and increased serum concentrations are occasionally observed in athletes. Therefore, given the athlete's connatural inclination to experiment with innovative, unfair and potentially unhealthy doping techniques, cobalt administration might soon become the most suited complement or surrogate for erythropoiesis-stimulating substances. Nevertheless, cobalt administration is not free from unsafe consequences, which involve toxic effects on heart, liver, kidney, thyroid and cancer promotion. Implications of the hypothesis Cobalt is easily purchasable, inexpensive and not currently comprehended within the World Anti-Doping Agency prohibited list. Moreover, available techniques for measuring whole blood, serum, plasma or urinary cobalt involve analytic approaches which are currently not practical for antidoping laboratories. Thus more research on cobalt metabolism in athletes is compelling, along with implementation of effective strategies to unmask this potentially deleterious doping practice

  11. Point-source inversion techniques

    Science.gov (United States)

    Langston, Charles A.; Barker, Jeffrey S.; Pavlin, Gregory B.

    1982-11-01

    A variety of approaches for obtaining source parameters from waveform data using moment-tensor or dislocation point source models have been investigated and applied to long-period body and surface waves from several earthquakes. Generalized inversion techniques have been applied to data for long-period teleseismic body waves to obtain the orientation, time function and depth of the 1978 Thessaloniki, Greece, event, of the 1971 San Fernando event, and of several events associated with the 1963 induced seismicity sequence at Kariba, Africa. The generalized inversion technique and a systematic grid testing technique have also been used to place meaningful constraints on mechanisms determined from very sparse data sets; a single station with high-quality three-component waveform data is often sufficient to discriminate faulting type (e.g., strike-slip, etc.). Sparse data sets for several recent California earthquakes, for a small regional event associated with the Koyna, India, reservoir, and for several events at the Kariba reservoir have been investigated in this way. Although linearized inversion techniques using the moment-tensor model are often robust, even for sparse data sets, there are instances where the simplifying assumption of a single point source is inadequate to model the data successfully. Numerical experiments utilizing synthetic data and actual data for the 1971 San Fernando earthquake graphically demonstrate that severe problems may be encountered if source finiteness effects are ignored. These techniques are generally applicable to on-line processing of high-quality digital data, but source complexity and inadequacy of the assumed Green's functions are major problems which are yet to be fully addressed.

  12. Sorption of 60Co on a synthetic titanosilicate analogue of the mineral penkvilksite-2O and antimonysilicate

    International Nuclear Information System (INIS)

    Koudsi, Y.; Dyer, A.

    2001-01-01

    The ability of two different types of synthetic inorganic ion-exchangers to sorb radioactive cobalt-60 using a batch-type method was studied. The two materials examined were the analogue of the natural titanosilicate penkvilksite-2O (AM-3) and a synthetic antimonysilicate. Ion-exchange experiments were performed with solutions labelled with radioactive cobalt ( 60 Co). The sorption of 60 Co onto the two samples materials were compared in terms of distribution coefficient (K d ), sorption percentage and cobalt quantity removed in mg per gram weight of the material. Several parameters were investigated viz. contact time, cobalt concentration, and sorbent concentration. It was found that the batch factor and cobalt concentration had a significant influence on the sorption of cobalt onto both of the materials. This was associated with the difference in pH generated by suspensions of the materials in water which was alkaline for the penkvilksite-2O analogue, and acid for the synthetic antimonysilicate. (author)

  13. Testing of cobalt-free alloys for valve applications using a special test loop

    International Nuclear Information System (INIS)

    Benhamou, C.

    1992-01-01

    Considering that use of cobalt alloys should be avoided as far as possible in PWR components, a programme aimed at establishing the performance of cobalt-free alloys has been performed for valve applications, where cobalt alloys are mainly used. Referring to past work, two types of cobalt-free alloys were selected: Ni-Cr-B-Si and Ni-Cr-Fe alloys. Cobalt-free valves' behaviour has been evaluated comparatively with cobalt valves by implementation of a programme in a special PWR test loop. At the issue of the loop test programme, which included endurance, thermal shock and erosion tests, cobalt-free alloys candidate to replace cobalt alloys are proposed in relation with valve type (globe valve and swing check valve). The following was established: (i) Colmonoy 4-26 (Ni-Cr-B-Si alloy) and Cenium Z20 (Ni-Cr-Fe alloy) deposited by plasma arc process were found suitable for use in 3inch swing check valves; (ii) for integral parts acting as guide rings, Nitronic 60 and Cesium Z20/698 were tested successfully; (iii) for small-bore components such as 2inch globe valves, no solution can yet be proposed; introduction of cobalt-free alloys is dependent on the development of automatic advanced arc surfacing techniques applied to small-bore components

  14. Dose rate measurement of a cobalt source 'Issledovatel' by means of Fricke dosimeter

    CERN Document Server

    Peimel-Stuglik, Z

    2001-01-01

    The results of measurements leading to the elaboration of a reliable and accurate dose rate determination for a cobalt irradiator 'Issledovatel' were presented. The dose measurements were done by means of classic Fricke dosimeter. The conclusions from measurements can be useful also for the dosimetry of other kinds of cobalt irradiators. The measurements were performed by a newly employed Laboratory for Measurements of Technological Doses staff and were a practical test of their proficiency in gamma ray dosimetry.

  15. UHE point source survey at Cygnus experiment

    International Nuclear Information System (INIS)

    Lu, X.; Yodh, G.B.; Alexandreas, D.E.; Allen, R.C.; Berley, D.; Biller, S.D.; Burman, R.L.; Cady, R.; Chang, C.Y.; Dingus, B.L.; Dion, G.M.; Ellsworth, R.W.; Gilra, M.K.; Goodman, J.A.; Haines, T.J.; Hoffman, C.M.; Kwok, P.; Lloyd-Evans, J.; Nagle, D.E.; Potter, M.E.; Sandberg, V.D.; Stark, M.J.; Talaga, R.L.; Vishwanath, P.R.; Zhang, W.

    1991-01-01

    A new method of searching for UHE point source has been developed. With a data sample of 150 million events, we have surveyed the sky for point sources over 3314 locations (1.4 degree <δ<70.4 degree). It was found that their distribution is consistent with a random fluctuation. In addition, fifty two known potential sources, including pulsars and binary x-ray sources, were studied. The source with the largest positive excess is the Crab Nebula. An excess of 2.5 sigma above the background is observed in a bin of 2.3 degree by 2.5 degree in declination and right ascension respectively

  16. Methods radiation protection data sheets for the use radionuclides in unsealed sources

    International Nuclear Information System (INIS)

    Anon.

    1999-01-01

    These radiation protection data sheets are devoted to responsible persons and employees of various laboratories or medical, pharmaceutical, university and industrial departments where radionuclides are handled as well as all the persons who attend to safety in this field. They contain the essential radiation protection data for the use of radionuclides in unsealed sources: physical characteristics, risk assessment, administrative procedures, recommendations, regulations and bibliography. This new series includes the following radionuclides: bromine 82, cobalt 58, cobalt 60, manganese 54, mercury 197, mercury 203, promethium 147, xenon 133 and ytterbium 169. (O.M.)

  17. Effect of Cobalt Supplementation on Performance of growing Calves

    Directory of Open Access Journals (Sweden)

    V.Nagabhushana

    Full Text Available The experiment was conducted to study the effect of critical supplementation of wheat straw with cobalt on fibre utilization and nutrient utilization in growing cross-bred male calves. Twenty-one crossbred (HF X Local male growing calves of 3-4 months age were fed with wheat straw based diet consisting without (Co0 and with 1 (Co1 and 6 (Co6 ppm cobalt as cobaltous chloride. There was no significant difference in intake of wheat straw, concentrate and DMI between the three groups and the ratio between concentrate and wheat straw was maintained at 40:60 irrespective of dietary level of cobalt. Similarly, average cumulative body weight, net gain in body weight or feed efficiency did not differ significantly between treatments. No significant effect was observed on the digestibility of dry matter, organic matter, crude protein, ether extract and fibre constituents like NDF, ADF, hemicellulose or cellulose by supplementation of 1 and 6 ppm Co to the diet of growing calves. Balance of nutrients such as Nitrogen, Calcium and Phosphorus was similar and positive in all the treatment groups. TDN and DCP values of the experimental diets remained almost similar irrespective of dietary level of cobalt. [Veterinary World 2008; 1(10.000: 299-302

  18. Concentration of radioactive cobalt by seaweeds in the food chain

    International Nuclear Information System (INIS)

    Nakahara, Motokazu; Koyanagi, Taku; Saiki, Masamichi

    1976-01-01

    On the pathway of radioactive substances in marine environments, seaweeds play an important role because of their higher concentration factors for many radionuclides and because they constitute a link of food chain in the sea. In the present work, uptake, distribution and excretion of radioactive cobalt were studied on several kinds of seaweeds by radioisotope tracer experiments under laboratory conditions and concentration factors were calculated. The concentration factors were also estimated from the results of stable cobalt determination by activation analysis or atomic absorption spectrometry on seaweeds and seawater, and compared with the results of tracer expts. The seaweeds showed the species specificity for the concentration of stable and radioactive cobalt with diverse values of concentration factors and biological half-lives. The transfer of radioactive cobalt in the food chain from contaminated seaweeds to mollusca was examined by feeding abalones, Haliotis discus, with four kinds of seaweed labelled with 60 Co and observing retention. Absorption rate for radioactive cobalt by abalones calculated at two days after feeding showed diverse values depending upon the species of seaweed, as follows: 47% through Laminaria japonica and Ulva pertusa, 31% through Undaria pinnatifida and 26 through Eisenia bicyclis, respectively. From the results, it was assumed that the accumulation of radioactive cobalt by mollusca is affected by the species of seaweeds as food. A very high concentration of ingested radioactive cobalt in the midgut gland was seen on the autoradiograph of abalone samples. (auth.)

  19. Concentration of radioactive cobalt by seaweeds in the food chain

    International Nuclear Information System (INIS)

    Nakahara, M.; Koyanagi, T.; Saiki, M.

    1975-01-01

    On the pathway of radioactive substances in marine environments, seaweeds play an important role because of their higher concentration factors for many radionuclides and because they constitute a link in the food chain. In the present work, uptake, distribution and excretion of radioactive cobalt were studied on several kinds of seaweeds by radioisotope tracer experiments under laboratory conditions and concentration factors were calculated. The concentration factors were also estimated from the results of stable cobalt determination by activation analysis or atomic absorption spectrometry on seaweeds and seawater, and compared with the results of tracer experiments. The seaweeds showed the species specificity for the concentration of stable and radioactive cobalt with diverse values of concentration factors and biological half-lives. The transfer of radioactive cobalt in the food chain from contaminated seaweeds to mollusca was examined by feeding abalones, Haliotis discus, with four kinds of seaweed labelled with 60 Co and observing retention. Absorption rate for radioactive cobalt by abalones calculated at two days after feeding showed diverse values depending upon the species of seaweed, as follows: 47% through Laminaria japonica and Ulva pertusa, 31% through Undaria pinnatifida and 26% through Eisenia bicyclis, respectively. From the results, it was assumed that the accumulation of radioactive cobalt by mollusca is affected by the species of seaweeds as food. A very high concentration of ingested radioactive cobalt in the midgut gland was seen on the autoradiograph of abalone samples. (author)

  20. Cobalt release from inexpensive jewellery

    DEFF Research Database (Denmark)

    Thyssen, Jacob Pontoppidan; Jellesen, Morten Stendahl; Menné, Torkil

    2010-01-01

    . Conclusions: This study showed that only a minority of inexpensive jewellery purchased in Denmark released cobalt when analysed with the cobalt spot test. As fashion trends fluctuate and we found cobalt release from dark appearing jewellery, cobalt release from consumer items should be monitored in the future......Objectives: The aim was to study 354 consumer items using the cobalt spot test. Cobalt release was assessed to obtain a risk estimate of cobalt allergy and dermatitis in consumers who would wear the jewellery. Methods: The cobalt spot test was used to assess cobalt release from all items...

  1. Point source reconstruction principle of linear inverse problems

    International Nuclear Information System (INIS)

    Terazono, Yasushi; Matani, Ayumu; Fujimaki, Norio; Murata, Tsutomu

    2010-01-01

    Exact point source reconstruction for underdetermined linear inverse problems with a block-wise structure was studied. In a block-wise problem, elements of a source vector are partitioned into blocks. Accordingly, a leadfield matrix, which represents the forward observation process, is also partitioned into blocks. A point source is a source having only one nonzero block. An example of such a problem is current distribution estimation in electroencephalography and magnetoencephalography, where a source vector represents a vector field and a point source represents a single current dipole. In this study, the block-wise norm, a block-wise extension of the l p -norm, was defined as the family of cost functions of the inverse method. The main result is that a set of three conditions was found to be necessary and sufficient for block-wise norm minimization to ensure exact point source reconstruction for any leadfield matrix that admit such reconstruction. The block-wise norm that satisfies the conditions is the sum of the cost of all the observations of source blocks, or in other words, the block-wisely extended leadfield-weighted l 1 -norm. Additional results are that minimization of such a norm always provides block-wisely sparse solutions and that its solutions form cones in source space

  2. PENGARUH RADIASI SINAR GAMMA COBALT-60 TERHADAP SIFAT MORFOLOGI DAN AGRONOMI KETIGA VARIETAS JAGUNG (ZEA MAYS L.

    Directory of Open Access Journals (Sweden)

    Makhziah

    2017-04-01

    Full Text Available Mutation is one of the ways to improve genetic variation in plant breeding so the target traits were more easily obtained. Grains of three varieties of maize (Bisma, Madura local, and Gumarang were treated with gamma 60cobalt irradiation doses (0, 100, 200, and 300 Gy before sowing then planted in a split plot randomized block design with three replication, to be evaluated for their morphology and agronomic traits. The Main plot was cultivars and sub plot was gamma radiation rates. There was no interaction between gamma rates and cultivars of maize, but increasing of gamma rates caused decreasing of some traits. Some traits such as plant height and leaves number were decreased significantly when gamma rate increased 100 to 300 Gy as well yield components such as grain weight and grain number per ear. Gamma 200 caused produce more ears than other rates. Bisma exhibited greater performance than Madura and Gumarang both of morphology and agronomic traits.

  3. Studied by electron paramagnetic resonance (EPR) of polymethyl methacrylate (PMMA) irradiated with gamma photons from cobalt 60

    International Nuclear Information System (INIS)

    Jalali, Hajer

    2013-01-01

    Ionizing radiation is radiation able to deposit enough energy in the material through which they pass to create ionization. These ionizing radiations, when mastered, have many practical uses beneficial (areas of health, industry ...). Gamma rays are emitted by radioactive nuclei. The objective of our work is the study of polymethyl methacrylate (PMMA) irradiated by gamma photons from cobalt-60. To study the technique of radio spectroscopy (9 to 10Hz) electron paramagnetic resonance EPR is used. This technique is specific to characterize transient free radicals involved in chemical reactions such as oxidation, combustion, polymerization reactions ... We analyzed the EPR spectra three batch KS, EB, and JF our dosimeter according to the dose (high and low) and showed that the dosimetric response can be represented in exponential form (high dose) and linear form (low dose). We also studied the kinetics of decay of the EPR signal as a function of time (fading) and showed that the responses relating to stabilize after 20 min of irradiation.

  4. Development of the irradiation facility SIBO INRA/Tangier, Morocco by upgrading cobalt-60 in a temporary pool and enhancing safety and control features

    Directory of Open Access Journals (Sweden)

    Mohammed Mouhib

    2017-12-01

    Full Text Available An automatic control system is one of the most important parts of an irradiation facility. The level of this control is always maintained to comply with safety procedures during routine work in this field. Also sometimes it is limited to the minimum level of regulation required due to economical aspects; some commercial systems are generally made by manufacturers of industrial facilities and considered affordable by irradiators. In some cases specific irradiation facilities tailor their control systems to their needs. For this kind of irradiator the control system can be developed and upgraded according to personal and industrial experiences. These upgrading procedures are also used by others to develop their systems. The objective of this paper is to share a local experience in upgrading security, safety systems and the use of cobalt-60 for the irradiator. It is a composite experiment at SIBO INRA/Tangier, Morocco and concerns the: (i upgrade of cobalt-60 in a temporary pool in the SIBO irradiator in Tangier. This operation was conducted in collaboration with the International Atomic Energy Agency (IAEA and was a success story of 2014 according to the general conference of IAEA; (ii safety and technical upgrade of the system in the SIBO irradiator made in collaboration with IAEA; (iii installation and upgrade of the security system in accordance with the Global Threat Reduction Programme (GTRP to reduce the threat of a Radiological Dispersal Device (RDD in collaboration with The United States Department of Energy’s National Nuclear Security Administration (NNSA.

  5. X pinch a point x-ray source

    International Nuclear Information System (INIS)

    Garg, A.B.; Rout, R.K.; Shyam, A.; Srinivasan, M.

    1993-01-01

    X ray emission from an X pinch, a point x-ray source has been studied using a pin-hole camera by a 30 kV, 7.2 μ F capacitor bank. The wires of different material like W, Mo, Cu, S.S.(stainless steel) and Ti were used. Molybdenum pinch gives the most intense x-rays and stainless steel gives the minimum intensity x-rays for same bank energy (∼ 3.2 kJ). Point x-ray source of size (≤ 0.5 mm) was observed using pin hole camera. The size of the source is limited by the size of the pin hole camera. The peak current in the load is approximately 150 kA. The point x-ray source could be useful in many fields like micro lithography, medicine and to study the basic physics of high Z plasmas. (author). 4 refs., 3 figs

  6. Monte Carlo dosimetric characterization of the Flexisource Co-60 high-dose-rate brachytherapy source using PENELOPE.

    Science.gov (United States)

    Almansa, Julio F; Guerrero, Rafael; Torres, Javier; Lallena, Antonio M

    60 Co sources have been commercialized as an alternative to 192 Ir sources for high-dose-rate (HDR) brachytherapy. One of them is the Flexisource Co-60 HDR source manufactured by Elekta. The only available dosimetric characterization of this source is that of Vijande et al. [J Contemp Brachytherapy 2012; 4:34-44], whose results were not included in the AAPM/ESTRO consensus document. In that work, the dosimetric quantities were calculated as averages of the results obtained with the Geant4 and PENELOPE Monte Carlo (MC) codes, though for other sources, significant differences have been quoted between the values obtained with these two codes. The aim of this work is to perform the dosimetric characterization of the Flexisource Co-60 HDR source using PENELOPE. The MC simulation code PENELOPE (v. 2014) has been used. Following the recommendations of the AAPM/ESTRO report, the radial dose function, the anisotropy function, the air-kerma strength, the dose rate constant, and the absorbed dose rate in water have been calculated. The results we have obtained exceed those of Vijande et al. In particular, the absorbed dose rate constant is ∼0.85% larger. A similar difference is also found in the other dosimetric quantities. The effect of the electrons emitted in the decay of 60 Co, usually neglected in this kind of simulations, is significant up to the distances of 0.25 cm from the source. The systematic and significant differences we have found between PENELOPE results and the average values found by Vijande et al. point out that the dosimetric characterizations carried out with the various MC codes should be provided independently. Copyright © 2017 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.

  7. Thermal effect on structure organizations in cobalt-fullerene nanocomposition.

    Science.gov (United States)

    Lavrentiev, Vasily; Vacik, Jiri; Naramoto, Hiroshi; Sakai, Seiji

    2010-04-01

    Effect of deposition temperature (Ts) on structure of Co-C60 nanocomposite (NC) prepared by simultaneous deposition of cobalt and fullerene on sapphire is presented. The NC structure variations with Ts increasing from room temperature (RT) to 400 degrees C have been analyzed using scanning electron microscopy (SEM), atomic force microscopy (AFM) and Raman spectroscopy. AFM and SEM show granule-like structure of the Co-C60 film. The mixture film deposited at RT includes the hills on the surface suggesting accumulation of internal stress during phase separation. Raman spectra show 25 cm(-1) downshift of Ag(2) C60 peak suggesting -Co-C60- polymerization in C60-based matrix of the NC film. Analysis of Raman spectra has revealed existence of amorphous carbon (a-C) in the NC matrix that argues C60 decomposition. The Ts increase to 200 degrees C causes the surface hills smoothing. In parallel, downshift of the Ag(2) peak decreases to 16 cm(-1) that implies more pronounced phase separation and lower -Co-C60- polymerization efficiency. Also, amount of a-C content slightly increases. Further Ts increasing to 400 degrees C changes the NC structure dramatically. AFM shows evident enlargement of the granules. According to Raman spectra the high Ts deposition yields pronounced C60 decomposition increasing the a-C content. Features of a-C Raman peak imply nucleation of graphitic islands at the NC interfaces. Abundant decomposition of C60 in the mixture film deposited at 400 degrees C is referred to cobalt catalytic effect.

  8. Enhancement of electrical conductivity in gamma irradiated cobalt ferrite nanoparticles

    International Nuclear Information System (INIS)

    Nawpute, Asha A.; Raut, A.V.; Babrekar, M.K.; Kale, C.M.; Jadhav, K.M.; Shinde, A.B.

    2014-01-01

    The cobalt ferrite nanoparticles were synthesized by sol-gel auto- combustion method, in which L-ascorbic acid was used as a fuel. The effect of gamma irradiation on the electrical resistivity of cobalt ferrite nanoparticles has been studied. The ferrite powder annealed at 550℃ was irradiated by gamma source 137 Cs. The synthesized nanoparticles were characterized by X-ray diffraction and DC resistivity. (author)

  9. Cobalt release from inexpensive jewellery: has the use of cobalt replaced nickel following regulatory intervention?

    Science.gov (United States)

    Thyssen, Jacob Pontoppidan; Jellesen, Morten S; Menné, Torkil; Lidén, Carola; Julander, Anneli; Møller, Per; Johansen, Jeanne Duus

    2010-08-01

    Before the introduction of the EU Nickel Directive, concern was raised that manufacturers of jewellery might turn from the use of nickel to cobalt following the regulatory intervention on nickel exposure. The aim was to study 354 consumer items using the cobalt spot test. Cobalt release was assessed to obtain a risk estimate of cobalt allergy and dermatitis in consumers who would wear the jewellery. The cobalt spot test was used to assess cobalt release from all items. Microstructural characterization was made using scanning electron microscope (SEM) and energy-dispersive spectroscopy (EDS). Cobalt release was found in 4 (1.1%) of 354 items. All these had a dark appearance. SEM/EDS was performed on the four dark appearing items which showed tin-cobalt plating on these. This study showed that only a minority of inexpensive jewellery purchased in Denmark released cobalt when analysed with the cobalt spot test. As fashion trends fluctuate and we found cobalt release from dark appearing jewellery, cobalt release from consumer items should be monitored in the future. Industries may not be fully aware of the potential cobalt allergy problem.

  10. Sedimentation of Cobalt-60 and Cesium-137 in the bay of Tvaeren 1964-1980

    International Nuclear Information System (INIS)

    Ramberg, L.; Lampe, S.

    1980-11-01

    Since 1964 the Co-60 and Cs-137 radioactivity of the sediments of the Tvaeren bay has been recorded every year at several points. Changes have been analysed in relation to atmospheric fallout releases from Studsvik distance from release point and depth. Estimates of total quantity for both nuclides bound up in the sediments and a forecast of future trends are presented. Sedimentation coefficients have been calculated and the factors which govern the degree of sedimentation are discussed.(G.B.)

  11. Cobalt release from implants and consumer items and characteristics of cobalt sensitized patients with dermatitis

    DEFF Research Database (Denmark)

    Thyssen, Jacob Pontoppidan; Menne, Torkil; Liden, Carola

    2012-01-01

    -containing dental alloys and revised hip implant components.Results. Six of eight dental alloys and 10 of 98 revised hip implant components released cobalt in the cobalt spot test, whereas none of 50 mobile phones gave positive reactions. The clinical relevance of positive cobalt test reactions was difficult......-tested dermatitis patients in an attempt to better understand cobalt allergy.Materials and methods. 19 780 dermatitis patients aged 4-99 years were patch tested with nickel, chromium or cobalt between 1985 and 2010. The cobalt spot test was used to test for cobalt ion release from mobile phones as well as cobalt...

  12. Determination of distribution coefficients for 134 Cs, 60 Co and 234 Th radionuclides in Pinheiro river sediment

    International Nuclear Information System (INIS)

    Lima, M.F.

    1992-01-01

    The distribution coefficients (K α) were determined in order to foresee the fate of the radionuclides discharged to the environment. Based upon the source-term released by IPEN's facilities in Pinheiros River during the year of 1988, three radionuclides were chosen as being the more critical, according to the radiation protection standards: 137 Cs, 60 Co and 232 Th. Their K α were determined experimentally in laboratory by using the corresponding radioactive tracers 134 Cs, 60 Co and 234 Th. Three different experimental methodologies were used: the static method, the shaken method and the dynamic method. The parameters studied were the effects of pH, aerobic condition and time of contact. The results obtained experimentally for the Kds confirm the predictions that: the cesium is slowly retained by the sediment along the Pinheiros River, the cobalt is an unstable element, therefore its retention by the sediment is affected by variations in the pH values, and finally, the thorium is almost completely retained in the vicinity of the discharge point. (author)

  13. Effective intermolecular potential and critical point for C60 molecule

    Science.gov (United States)

    Ramos, J. Eloy

    2017-07-01

    The approximate nonconformal (ANC) theory is applied to the C60 molecule. A new binary potential function is developed for C60, which has three parameters only and is obtained by averaging the site-site carbon interactions on the surface of two C60 molecules. It is shown that the C60 molecule follows, to a good approximation, the corresponding states principle with n-C8H18, n-C4F10 and n-C5F12. The critical point of C60 is estimated in two ways: first by applying the corresponding states principle under the framework of the ANC theory, and then by using previous computer simulations. The critical parameters obtained by applying the corresponding states principle, although very different from those reported in the literature, are consistent with the previous results of the ANC theory. It is shown that the Girifalco potential does not correspond to an average of the site-site carbon-carbon interaction.

  14. Effects of cobalt-60 low doses radiation on beam, rice and radish seeds

    International Nuclear Information System (INIS)

    Kikuchi, O.K.

    1987-01-01

    The effects of cobalt-60 gamma radiation on seeds of bean (Phaseolus vulgaris L.), rice (Oryza sativa L.) and radish (Raphanus sativus L.) were studied. Bean and rice seeds were irradiated with 3.5 and 7.7 Gy (32 Gy/h). There was an apparent acceleration on rice seed germination with 3.5 Gy when they were stored for 6 days after irradiation, but the same dose caused a delay when the store time was 1 day. Bean seeds germination was not modified by 3.5 and 7.7 Gy, but the fresh and dry weight of young plants showed an increase, mainly due the major quantity of water in the embryonic axis. Bean seeds were irradiated with 0.5 and 2.0 Gy (30 Gy/h). Seeds germination showed a slight delay irradiating with 0.5 Gy, while height, fresh and dry weight and primary leaves area of the young plants as well as number of nodes, leaves, flowers, beans and seeds were not modified after irradiation with 0.5 and 2.0 Gy. Radish seeds irradiated with 10 and 30 Gy at dose rates of 4.5, 22.5 and 45.0 Gy/h showed a germination delay and fresh and dry weight values for young plants leaves lower than control. Roots of totally developed plants showed no modifications in weight, volume, mean diameter, lenght and in the amount of soluble reducing sugar. (author)

  15. Preoperative cobalt{sup 60} irradiation delays the healing of rectal anastomoses in rats

    Energy Technology Data Exchange (ETDEWEB)

    Fang, C.B.; Klug, W.A.; Capelhuchnik, P. [Santa Casa de Misericordia de Sao Paulo, SP (Brazil). Faculdade de Ciencias Medicas. Dept. de Cirurgia]. E-mail: colon.reto@terra.com.br

    2005-06-15

    The healing of colorectal anastomoses after irradiation therapy continues to be a major concern. The authors evaluated the healing of rectal anastomoses in a rat model after a preoperative 500-c Gy dose of cobalt 60 irradiation. Thirty-six male Wistar rats were divided into two equal groups: control (group A), and irradiation group (group B). Group B received a single 500-c Gy dose of irradiation, and a rectal resection and end-to-end anastomosis was performed in both groups on the seventh day after irradiation. Parameters of the healing process included bursting pressure and collagen content on the fifth, seventh, and fourteenth days after surgery. In the irradiation group, the mean bursting pressure on the fifth, seventh, and fourteenth days was 116, 218, and 273 mmHg, respectively. The collagen content assessed by histomorphometry was 9.0, 20.8, and 32%, respectively. In contrast, the control group had a mean bursting pressure of 175, 225 and 263 mmHg, and a collagen content of 17.8, 28.1, and 32.1%, respectively. The adverse effect of irradiation on healing was detectable only on the fifth postoperative day, as demonstrated by lower bursting pressure (P < 0.013) and collagen content (P < 0.008). However, there was no failure of anastomotic healing such as leakage or dehiscence due to irradiation. We conclude that a single preoperative 500-c Gy dose of irradiation delays the healing of rectal anastomosis in rats. (author)

  16. Induced chlorophyll variation in pineapple c v. 'queen' by gamma irradiation (60Cobalt)

    International Nuclear Information System (INIS)

    Valencia, Lolita DC.

    2012-01-01

    Irradiation using gamma rays ( 60 Cobalt) coupled with in vitro culture techniques was undertaken to induce variation or mutation in pineapple. Calli from crown meristem tips of pineapple cv 'Queen' [Ananas comosus (L.) Merr.] were initiated using Murashiege and Skoog's basal meduim supplemented with 10mg/liter 4-amino-3,5,6-trichloro-2-pyrodinecarboxylic acid (Picloram). High percentage of growth and shoot proliferation was observed in basal medium supplemented with 50 μM benzene adenine purine (BAP) and 10 μM gibberrelic acid (GA) after 8 weeks in vitro. Regenerants derived from shoots using different doses of gamma rays (0, 5, 10, 15, 20, 25 and 30 Gy) were evaluated under laboratory conditions. Of the different doses, 15 Gy produced the most variegation in young shoots (chlorophyll variants) maintained in vitro. The variants appeared to have yellow and green color combinations of the young leaves of pineapple 'Queen' variety. When transplanted inside the greenhouse, high percentage of plantlets survival was observed, ranging from 90-95%. Of the different irradiation doses, variegation in young leaves was observed at 15, 20, 25 and 30 Gy. Further assessment on the effect of irradiation is currently being unertaken under screen house conditions. The variants produced could serve a basis for selection of ornamental-type pineapple. In addition, protocols developed on the use of in vitro culture techniques could be utilized as a tool for induced mutation breeding in pineapple. (author)

  17. Evaluation of gamma radiation (60-Co) induced mutation in two Phaseolus vulgaris varieties

    International Nuclear Information System (INIS)

    Silva, R.M.

    1984-01-01

    Two varieties of Phaseolus vulgaris (Jutiapan and San Martin) were irradiated at 0, 8, 15, 20 and 30 kR doses in a 60-cobalt gamma source, to identify mutants and 20% lethality. M 2 plants showing morphogical mutations were selected. Differences in sensitivity to irradiation of the two varieties were noted, using data and physiological effects of M 1 . Selection and analysis for protein content were in M 3 as well as hereditary changes. (M.A.C.) [pt

  18. Distribution of cobalt in soil from Kavadarci and the environs

    International Nuclear Information System (INIS)

    Stafilov, Trajche; Shajn, Robert; Boev, Blazho; Cvetkovich, Julujana; Mukaetov, Dushko; Andreevski, Marjan; Lepitkova, Sonja

    2009-01-01

    The results of the study of spatial distribution of cobalt in surface soil and subsoil over of the Kavadarci region, Republic of Macedonia, are reported. From the investigated region (360 km 2 ) in total 344 soil samples from 172 locations were collected. At each sampling point soil samples were collected at two depths, topsoil (0-5 cm) and subsoil soil (20-30 cm). Inductively coupled plasma - mass spectrometry (ICP-MS) was applied for the determination of cobalt. Data analysis and construction of the map were performed using the Paradox (ver. 9), Statistica (ver. 6.1), AutoDesk Map (ver. 2008) and Surfer (ver. 8.09) software. It was found that for both topsoil and subsoil the median and average values are 15 mg/kg, ranges between 6.7 and 58 mg/kg. The highest content of cobalt is present in the soil from the area of Paleozoic and Mesozoic rocks (Pz-Mz) on the western part of the investigated area and Flysch (E) - Eocene upper flysch zone (on the northern part) and the lowest in the soils from the Holocene alluvium of the rivers Crna Reka and Vardar. There are no significant differences between the surface and subsoil in terms of its average quantities. It was found that the critically high contents are related primarily to high contents of cobalt in the sampling points from the western part of the investigated region. The contents of cobalt are higher in subsoil than in topsoil from which it can be concluded that the occurrence is natural.

  19. Cesium-137 as a radiation source

    International Nuclear Information System (INIS)

    McMullen, W.H.; Sloan, D.P.

    1985-01-01

    The U.S. Department of Energy (DOE) Byproducts Utilization Program (BUP) seeks to develop and encourage widespread commercial use of defense byproducts that are produced by DOE. Cesium-l37 is one such byproduct that is radioactive and decays with emission of gamma rays. The beneficial use of this radiation to disinfect sewage sludge or disinfest food commodities is actively being pursued by the program. The radiation produced by cesium-l37(Cs-l37) is identical in form to that produced by cobalt-60(Co-60), an isotope that is widely used in commercial applications such as medical product sterilization. The choice of isotope to use depends on several factors ranging from inherent properties of the isotopes to availability and cost. The BUP, although centrally concerned with the beneficial use of Cs-l37, by investigating and assessing the feasibility of various uses hopes to define appropriate circumstances where cesium or cobalt might best be used to accomplish specific objectives. This paper discusses some of the factors that should be considered when evaluating potential uses for isotopic sources

  20. Studies of the yields of 57Fe(II)-species produced after the EC-decay and of 60Co(II)-species produced in the (n, γ) reaction in cobalt(III) coordination compounds

    International Nuclear Information System (INIS)

    Sano, Hirotoshi; Harada, Masayuki; Endo, Kazutoyo

    1978-01-01

    The yields of 57 Fe(II)-species produced after EC-decay were compared with those of 60 Co(II)-species produced in the 59 Co(n, γ) 60 Co reaction for twelve cobalt(III) coordination compounds. The results indicate that the radiochemical yield of 60 Co(II)-species correlates with the yield of 57 Fe(II)-species except in the case of [Co(NH 3 ) 6 ] 2 (CrO 4 ) 3 . The anomalously low yield of 57 Fe(II)-species in [Co(NH 3 ) 6 ] 2 (CrO 4 ) 3 is ascribed to the reaction of chromate anions with ammine ligands initiated by the nuclear transformation in a solid. (author)

  1. Cobalt toxicity in humans-A review of the potential sources and systemic health effects.

    Science.gov (United States)

    Leyssens, Laura; Vinck, Bart; Van Der Straeten, Catherine; Wuyts, Floris; Maes, Leen

    2017-07-15

    Cobalt (Co) and its compounds are widely distributed in nature and are part of numerous anthropogenic activities. Although cobalt has a biologically necessary role as metal constituent of vitamin B 12 , excessive exposure has been shown to induce various adverse health effects. This review provides an extended overview of the possible Co sources and related intake routes, the detection and quantification methods for Co intake and the interpretation thereof, and the reported health effects. The Co sources were allocated to four exposure settings: occupational, environmental, dietary and medical exposure. Oral intake of Co supplements and internal exposure through metal-on-metal (MoM) hip implants deliver the highest systemic Co concentrations. The systemic health effects are characterized by a complex clinical syndrome, mainly including neurological (e.g. hearing and visual impairment), cardiovascular and endocrine deficits. Recently, a biokinetic model has been proposed to characterize the dose-response relationship and effects of chronic exposure. According to the model, health effects are unlikely to occur at blood Co concentrations under 300μg/l (100μg/l respecting a safety factor of 3) in healthy individuals, hematological and endocrine dysfunctions are the primary health endpoints, and chronic exposure to acceptable doses is not expected to pose considerable health hazards. However, toxic reactions at lower doses have been described in several cases of malfunctioning MoM hip implants, which may be explained by certain underlying pathologies that increase the individual susceptibility for Co-induced systemic toxicity. This may be associated with a decrease in Co bound to serum proteins and an increase in free ionic Co 2+ . As the latter is believed to be the primary toxic form, monitoring of the free fraction of Co 2+ might be advisable for future risk assessment. Furthermore, future research should focus on longitudinal studies in the clinical setting of Mo

  2. Design and Simulation of 5-DOF Vision-Based Manipulator to Increase Radiation Safety for Industrial Cobalt-60 Irradiators

    International Nuclear Information System (INIS)

    Solyman, A.E.; Keshk, A.B.; Sharshar, K.A.; Roman, M.R.

    2016-01-01

    Robotics has proved its efficiency in nuclear and radiation fields. Computer vision is one of the advanced approaches used to enhance robotic efficiency. The current work investigates the possibility of using a vision-based controlled arm robot to collect the fallen hot Cobalt-60 capsules inside wet storage pool of industrial irradiator. A 5-DOF arm robot is designed and vision algorithms are established to pick the fallen capsules on the bottom surface of the storage pool, read the information printed on its edge (cap) and move it to a safe storage place. Two object detection approaches are studied; RGB-based filter and background subtraction technique. Vision algorithms and camera calibration are done using MATLAB/SIMULINK program. Robot arm forward and inverse kinematics are developed and programmed using an embedded micro controller system. Experiments show the validity of the proposed system and prove its success. The collecting process will be done without interference of operators, hence radiation safety will be increased.

  3. A copper-catalyzed bioleaching process for enhancement of cobalt dissolution from spent lithium-ion batteries

    Energy Technology Data Exchange (ETDEWEB)

    Zeng, Guisheng, E-mail: zengguisheng@hotmail.com [Key Laboratory of Jiangxi Province for Ecological Diagnosis-Remediation and Pollution Control, Nanchang Hangkong University, Nanchang 330063 (China); College of Chemistry and Chemical Engineering, Hunan University, Changsha 410082 (China); Deng, Xiaorong [Key Laboratory of Jiangxi Province for Ecological Diagnosis-Remediation and Pollution Control, Nanchang Hangkong University, Nanchang 330063 (China); School of Environment and Chemical Engineering, Nanchang Hangkong University, Nanchang 330063 (China); Luo, Shenglian, E-mail: sllou@hnu.edu.cn [Key Laboratory of Jiangxi Province for Ecological Diagnosis-Remediation and Pollution Control, Nanchang Hangkong University, Nanchang 330063 (China); College of Chemistry and Chemical Engineering, Hunan University, Changsha 410082 (China); School of Environment and Chemical Engineering, Nanchang Hangkong University, Nanchang 330063 (China); Luo, Xubiao; Zou, Jianping [Key Laboratory of Jiangxi Province for Ecological Diagnosis-Remediation and Pollution Control, Nanchang Hangkong University, Nanchang 330063 (China); School of Environment and Chemical Engineering, Nanchang Hangkong University, Nanchang 330063 (China)

    2012-01-15

    Highlights: Black-Right-Pointing-Pointer Catalytic ion was first applied to the bioleaching process of spent lithium-ion batteries. Black-Right-Pointing-Pointer The bioleaching efficiency was great improved from 43.1% to 99.9% in the presence of copper ion. Black-Right-Pointing-Pointer A new reaction model was proposed to explain the catalytic mechanism. - Abstract: A copper-catalyzed bioleaching process was developed to recycle cobalt from spent lithium-ion batteries (mainly LiCoO{sub 2}) in this paper. The influence of copper ions on bioleaching of LiCoO{sub 2} by Acidithiobacillus ferrooxidans (A.f) was investigated. It was shown that almost all cobalt (99.9%) went into solution after being bioleached for 6 days in the presence of 0.75 g/L copper ions, while only 43.1% of cobalt dissolution was obtained after 10 days without copper ions. EDX, XRD and SEM analyses additionally confirmed that the cobalt dissolution from spent lithium-ion batteries could be improved in the presence of copper ions. The catalytic mechanism was investigated to explain the enhancement of cobalt dissolution by copper ions, in which LiCoO{sub 2} underwent a cationic interchange reaction with copper ions to form CuCo{sub 2}O{sub 4} on the surface of the sample, which could be easily dissolved by Fe{sup 3+}.

  4. Sorption of 60 Co in natural zeolite (clinoptilolite)

    International Nuclear Information System (INIS)

    Hernandez B, E.

    1996-01-01

    A Mexican zeolite (clinoptilolite) from Taxco, Guerrero, was partially stabilized with sodium cations. Radioactive Cobalt ( 60 Co) was used to study the Co 2+ sorption in the stabilized zeolite (Na + ). It was found that sorption in general does not favour the diffusion of cobalt between framework, it explains because of it is a natural zeolite and its composition heterogeneous decrease its exchange capacity by the generated competence to the existence other type of exchange ions. The cobalt retention reached the highest level, around 0.408 m eq Co 2+ /g in the Na-Clinoptilolite. The crystallinity of the aluminosilicates was maintained during experiments, it was verified by XRD patterns. (Author)

  5. Early effects of treatment with radium and cobalt-60 gamma radiation on the proportions and absolute counts of T and B lymphocytes in peripheral blood of women with cervical carcinoma

    International Nuclear Information System (INIS)

    Pluzanska, A.; Robak, T.; Kuchowicz, W.; Bartuzel, T.; Studencki, E.; Zadrozna, O.; Mazurowa, A.

    1977-01-01

    In 20 women with cervical carcinoma the T and B lymphocyte counts were determined in peripheral blood. The determinations were carried out before starting treatment and immediately after radium therapy in a mean dose of 6573 mgh and then after full therapeutic dose of cobalt-60 radiation of 4000 R. For identification of T lymphocytes the rosette E test was used and lymphocytes B were identified by means of the EAC rosette test. Presence of immunoglobulins on lymphocytes B was determined as well. In women with cervical carcinoma the total lymphocyte count in 1 mm 3 of blood, the proportions and absolute counts of T and B lymphocytes were not different from those in healthy women. Immediately after radium therapy the lymphocyte count in peripheral blood fell which was due mainly to a fall of the total count and in the proportion of B lymphocytes. The proportion of lymphocytes T was unchanged and their quantitative fall was statistically not significant. After application of the total therapeutic dose of cobalt-60 radiation a further fall of lymphocyte count was observed, due to a fall of the absolute count of T and B lymphocytes. Their proportions were unchanged. (author)

  6. 2011 Radioactive Materials Usage Survey for Unmonitored Point Sources

    Energy Technology Data Exchange (ETDEWEB)

    Sturgeon, Richard W. [Los Alamos National Laboratory

    2012-06-27

    This report provides the results of the 2011 Radioactive Materials Usage Survey for Unmonitored Point Sources (RMUS), which was updated by the Environmental Protection (ENV) Division's Environmental Stewardship (ES) at Los Alamos National Laboratory (LANL). ES classifies LANL emission sources into one of four Tiers, based on the potential effective dose equivalent (PEDE) calculated for each point source. Detailed descriptions of these tiers are provided in Section 3. The usage survey is conducted annually; in odd-numbered years the survey addresses all monitored and unmonitored point sources and in even-numbered years it addresses all Tier III and various selected other sources. This graded approach was designed to ensure that the appropriate emphasis is placed on point sources that have higher potential emissions to the environment. For calendar year (CY) 2011, ES has divided the usage survey into two distinct reports, one covering the monitored point sources (to be completed later this year) and this report covering all unmonitored point sources. This usage survey includes the following release points: (1) all unmonitored sources identified in the 2010 usage survey, (2) any new release points identified through the new project review (NPR) process, and (3) other release points as designated by the Rad-NESHAP Team Leader. Data for all unmonitored point sources at LANL is stored in the survey files at ES. LANL uses this survey data to help demonstrate compliance with Clean Air Act radioactive air emissions regulations (40 CFR 61, Subpart H). The remainder of this introduction provides a brief description of the information contained in each section. Section 2 of this report describes the methods that were employed for gathering usage survey data and for calculating usage, emissions, and dose for these point sources. It also references the appropriate ES procedures for further information. Section 3 describes the RMUS and explains how the survey results are

  7. Keeping Sealed Radioactive Sources Safe and Secure

    International Nuclear Information System (INIS)

    Potterton, Louise

    2013-01-01

    Radioactive sources are used in a wide variety of devices in medical, industrial, agricultural and research facilities worldwide. These sources, such as cobalt-60 and caesium-137, emit high levels of ionizing radiation, which can treat cancer, measure materials used in industry and sterilize food and medical appliances. Problems may arise when these sources are no longer needed, or if they are damaged or decayed. If these sources are not properly stored they can be a threat to human health and the environment and pose a security risk. Procedures to secure these spent or 'disused' sources are often highly expensive and need specialized assistance. The IAEA helps its States find long term solutions for the safe and secure storage of disused sealed radioactive sources (DSRSs)

  8. [A landscape ecological approach for urban non-point source pollution control].

    Science.gov (United States)

    Guo, Qinghai; Ma, Keming; Zhao, Jingzhu; Yang, Liu; Yin, Chengqing

    2005-05-01

    Urban non-point source pollution is a new problem appeared with the speeding development of urbanization. The particularity of urban land use and the increase of impervious surface area make urban non-point source pollution differ from agricultural non-point source pollution, and more difficult to control. Best Management Practices (BMPs) are the effective practices commonly applied in controlling urban non-point source pollution, mainly adopting local repairing practices to control the pollutants in surface runoff. Because of the close relationship between urban land use patterns and non-point source pollution, it would be rational to combine the landscape ecological planning with local BMPs to control the urban non-point source pollution, which needs, firstly, analyzing and evaluating the influence of landscape structure on water-bodies, pollution sources and pollutant removal processes to define the relationships between landscape spatial pattern and non-point source pollution and to decide the key polluted fields, and secondly, adjusting inherent landscape structures or/and joining new landscape factors to form new landscape pattern, and combining landscape planning and management through applying BMPs into planning to improve urban landscape heterogeneity and to control urban non-point source pollution.

  9. Cobalt as a gastric juice volume marker: Comparison of two methods of estimation

    International Nuclear Information System (INIS)

    Gana, T.J.; MacPherson, B.R.; Ng, D.; Koo, J.

    1990-01-01

    We investigated the use of cobalt-EDTA, a novel, nonabsorbable liquid phase marker, in the estimation of secretory volumes during topical misoprostol (synthetic PGE, analog) administration in the canine chambered gastric segment. We compared atomic absorption spectrophotometry (AAS) and instrumental neutron activation analysis (INAA) in the estimation of [Co]. Mucosal bathing solutions containing cobalt-EDTA were instilled into and recovered from the chamber by gravity every 15-min period as follows: (i) basal--60 min; (ii) misoprostol periods--150 min (plus 0.1-, 1-, 10-, 100-, and 1000-micrograms doses of misoprostol for two periods per dose). The recovered solutions were analyzed for [Co] by AAS and INAA. Total cobalt recovery by AAS after chamber washout was 102.97 +/- 0.98%. Mean +/- SE volumes (12.14 +/- 0.33 and 13.24 +/- 0.60 ml/15 min) obtained respectively from AAS and INAA were significantly higher (P less than 0.001) than the recovered mean volumes (10.51 +/- 0.17 ml/15 min). The percentage error in volume collection increased (range: 9.3-52.7%) with the volume of secretion. Values of [Co] obtained by the two techniques were comparable and not significantly different from each other (P greater than 0.05). INAA-estimated mean +/- SE [Co] showed consistently higher coefficients of variation. Spectra obtained for all samples during INAA measurements showed significant Compton background activity from 24Na and 38Cl. Cobalt-EDTA did not grossly or histologically damage the gastric mucosa. We conclude that cobalt is not adsorbed, absorbed, or metabolized, and is a suitable and reliable volume marker in this model

  10. R1800: a new Co 60 sealed source

    International Nuclear Information System (INIS)

    Freijo, Jose L.; Gomez, Gonzalo

    2005-01-01

    The increasing demand of Co 60 sealed sources in the international market has made necessary the development of new models of sealed sources. R 1800 type source up to 65 KCi has a design that allows to accommodate a wide spectrum of capsules with different specific activities. The company Dioxitek has developed the fabrication process and the design specifications needed to obtain the approval of the product. A first shipment of 100 KCi has been made with success to the United Kingdom in October of the current year. (author) [es

  11. Passivation and corrosion behaviours of cobalt and cobalt-chromium-molybdenum alloy

    International Nuclear Information System (INIS)

    Metikos-Hukovic, M.; Babic, R.

    2007-01-01

    Passivation and corrosion behaviour of the cobalt and cobalt-base alloy Co30Cr6Mo was studied in a simulated physiological solution containing chloride and bicarbonate ions and with pH of 6.8. The oxido-reduction processes included solid state transformations occurring at the cobalt/electrolyte interface are interpreted using theories of surface electrochemistry. The dissolution of cobalt is significantly suppressed by alloying it with chromium and molybdenum, since the alloy exhibited 'chromium like' passivity. The structural and protective properties of passive oxide films formed spontaneously at the open circuit potential or during the anodic polarization were studied using electrochemical impedance spectroscopy in the wide frequency range

  12. On the point-source approximation of earthquake dynamics

    Directory of Open Access Journals (Sweden)

    Andrea Bizzarri

    2014-06-01

    Full Text Available The focus on the present study is on the point-source approximation of a seismic source. First, we compare the synthetic motions on the free surface resulting from different analytical evolutions of the seismic source (the Gabor signal (G, the Bouchon ramp (B, the Cotton and Campillo ramp (CC, the Yoffe function (Y and the Liu and Archuleta function (LA. Our numerical experiments indicate that the CC and the Y functions produce synthetics with larger oscillations and correspondingly they have a higher frequency content. Moreover, the CC and the Y functions tend to produce higher peaks in the ground velocity (roughly of a factor of two. We have also found that the falloff at high frequencies is quite different: it roughly follows ω−2 in the case of G and LA functions, it decays more faster than ω−2 for the B function, while it is slow than ω−1 for both the CC and the Y solutions. Then we perform a comparison of seismic waves resulting from 3-D extended ruptures (both supershear and subshear obeying to different governing laws against those from a single point-source having the same features. It is shown that the point-source models tend to overestimate the ground motions and that they completely miss the Mach fronts emerging from the supershear transition process. When we compare the extended fault solutions against a multiple point-sources model the agreement becomes more significant, although relevant discrepancies still persist. Our results confirm that, and more importantly quantify how, the point-source approximation is unable to adequately describe the radiation emitted during a real world earthquake, even in the most idealized case of planar fault with homogeneous properties and embedded in a homogeneous, perfectly elastic medium.

  13. Dosimetric comparison between the microSelectron HDR 192Ir v2 source and the BEBIG 60Co source for HDR brachytherapy using the EGSnrc Monte Carlo transport code

    International Nuclear Information System (INIS)

    Anwarul Islam, M.; Akramuzzaman, M.M.; Zakaria, G.A.

    2012-01-01

    Manufacturing of miniaturized high activity 192 Ir sources have been made a market preference in modern brachytherapy. The smaller dimensions of the sources are flexible for smaller diameter of the applicators and it is also suitable for interstitial implants. Presently, miniaturized 60 Co HDR sources have been made available with identical dimensions to those of 192 Ir sources. 60 Co sources have an advantage of longer half life while comparing with 192 Ir source. High dose rate brachytherapy sources with longer half life are logically pragmatic solution for developing country in economic point of view. This study is aimed to compare the TG-43U1 dosimetric parameters for new BEBIG 60 Co HDR and new microSelectron 192 Ir HDR sources. Dosimetric parameters are calculated using EGSnrc-based Monte Carlo simulation code accordance with the AAPM TG-43 formalism for microSelectron HDR 192 Ir v2 and new BEBIG 60 Co HDR sources. Air-kerma strength per unit source activity, calculated in dry air are 9.698x10 -8 ± 0.55% U Bq -1 and 3.039x10 -7 ± 0.41% U Bq -1 for the above mentioned two sources, respectively. The calculated dose rate constants per unit air-kerma strength in water medium are 1.116±0.12% cGy h -1 U -1 and 1.097±0.12% cGy h -1 U -1 , respectively, for the two sources. The values of radial dose function for distances up to 1 cm and more than 22 cm for BEBIG 60 Co HDR source are higher than that of other source. The anisotropic values are sharply increased to the longitudinal sides of the BEBIG 60 Co source and the rise is comparatively sharper than that of the other source. Tissue dependence of the absorbed dose has been investigated with vacuum phantom for breast, compact bone, blood, lung, thyroid, soft tissue, testis, and muscle. No significant variation is noted at 5 cm of radial distance in this regard while comparing the two sources except for lung tissues. The true dose rates are calculated with considering photon as well as electron transport using

  14. An Efficient and Recyclable Nanoparticle-Supported Cobalt Catalyst for Quinoxaline Synthesis

    Directory of Open Access Journals (Sweden)

    Fatemeh Rajabi

    2015-11-01

    Full Text Available The syntheses of quinoxalines derived from 1,2-diamine and 1,2-dicarbonyl compounds under mild reaction conditions was carried out using a nanoparticle-supported cobalt catalyst. The supported nanocatalyst exhibited excellent activity and stability and it could be reused for at least ten times without any loss of activity. No cobalt contamination could be detected in the products by AAS measurements, pointing to the excellent activity and stability of the Co nanomaterial.

  15. Influence of the protective cream and synthetic zeolites on the transfer of the 60Co across the skin of rat

    International Nuclear Information System (INIS)

    Kassai, Z.; Koprda, V.; Harangozo, M.; Palinkasova, A.; Bauerova, K.

    2000-01-01

    In this paper the influence of protection cream and synthetic zeolite on the transfer of the cobalt-60 across the skin of rat was examined. Influence of different methods of cream application on kinetics of cobalt-60 permeation is described

  16. Subcutaneous injection of 99mTc pertechnetate at acupuncture points K-3 and B-60

    International Nuclear Information System (INIS)

    Wu Chung-Chieng; Jong Shiang-Bin; Lin Chun-Ching; Chen Min-Fen; Chen Jong-Rern; Chung Chieng.

    1990-01-01

    The acupuncture points are known to be morphologically related to the nerves and vessels. Yet the physiological role of blood vessels in the formation of acupuncture points remains unknown. With subcutaneous injection of 99m Tc pertechnetate at the acupuncture points K-3 and B-60 and with intra-acupuncture point injection of 99m Tc pertechnetate at K-3 and B-60, a lower-limb venography like what was obtained by intravenous injection of 99m Tc macroaggregated albumin was demonstrated in the present study. It seems that some acupuncture points do play a role in drainage of tissue fluid from soft tissue into the veins. (author)

  17. Rainfall Deduction Method for Estimating Non-Point Source Pollution Load for Watershed

    OpenAIRE

    Cai, Ming; Li, Huai-en; KAWAKAMI, Yoji

    2004-01-01

    The water pollution can be divided into point source pollution (PSP) and non-point source pollution (NSP). Since the point source pollution has been controlled, the non-point source pollution is becoming the main pollution source. The prediction of NSP load is being increasingly important in water pollution controlling and planning in watershed. Considering the monitoring data shortage of NPS in China, a practical estimation method of non-point source pollution load --- rainfall deduction met...

  18. Elicitation threshold of cobalt chloride

    DEFF Research Database (Denmark)

    Fischer, Louise A; Johansen, Jeanne D; Voelund, Aage

    2016-01-01

    : On the basis of five included studies, the ED10 values of aqueous cobalt chloride ranged between 0.0663 and 1.95 µg cobalt/cm(2), corresponding to 30.8-259 ppm. CONCLUSIONS: Our analysis provides an overview of the doses of cobalt that are required to elicit allergic cobalt contactdermatitis in sensitized...

  19. Off-site source recovery project case study: disposal of high activity cobalt 60 sources at the Nevada test site 2008

    International Nuclear Information System (INIS)

    Cocina, Frank G.; Stewart, William C.; Wald-Hopkins, Mark; Hageman, John P.

    2009-01-01

    The Off-Site Source Recovery Project has been operating at Los Alamos National Laboratory since 1998 to address the U.S. Department of Energy responsibility for collection and management of orphaned or disused radioactive sealed sources which may represent a risk to public health and national security if not properly managed.

  20. Characteristics of infrared point sources associated with OH masers

    International Nuclear Information System (INIS)

    Mu Jimang; Esimbek, Jarken; Zhou Jianjun; Zhang Haijuan

    2010-01-01

    We collect 3249 OH maser sources from the literature published up to April 2007, and compile a new catalog of OH masers. We look for the exciting sources of these masers and their infrared properties from IRAS and MSX data, and make a statistical study. MSX sources associated with stellar 1612 MHz OH masers are located mainly above the blackbody line; this is caused by the dust absorption of stellar envelopes, especially in the MSX A band. The mid-IR sources associated with stellar OH masers are concentrated in a small region in an [A]-[D] vs. [A]-[E] diagram with a small fraction of contamination; this gives us a new criterion to search for new stellar OH masers and distinguish stellar masers from unknown types of OH masers. IR sources associated with 1612 MHz stellar OH masers show an expected result: the average flux of sources with F60 > F25 increases with increasing wavelength, while those with F60 F25.

  1. Water hyacinth for phytoremediation of radioactive waste simulate contaminated with cesium and cobalt radionuclides

    Energy Technology Data Exchange (ETDEWEB)

    Saleh, H.M., E-mail: hosamsaleh70@yahoo.com [Radioisotope Department, Nuclear Research Center, Atomic Energy Authority, Dokki 12311, Giza (Egypt)

    2012-01-15

    Highlights: Black-Right-Pointing-Pointer Phytoremediation of radioactive wastes containing {sup 137}Cs and {sup 60}Co radionuclides. Black-Right-Pointing-Pointer Using water hyacinth for radioactive waste treatment. Black-Right-Pointing-Pointer Bioaccumulation of radionuclides from radioactive waste streams. Black-Right-Pointing-Pointer Factors affecting bioaccumulation of {sup 137}Cs and {sup 60}Co using floating plants. - Abstract: Phytoremediation is based on the capability of plants to remove hazardous contaminants present in the environment. This study aimed to demonstrate some factors controlling the phytoremediation efficiency of live floating plant, water hyacinth (Eichhornia crassipes), towards the effluents contaminated with {sup 137}Cs and/or {sup 60}Co. Cesium has unknown vital biological role for plant while cobalt is one of the essential trace elements required for plant. The main idea of this work i.e. using undesirable species, water hyacinth, in purification of radiocontaminated aqueous solutions has been receiving much attention. The controlling factors such as radioactivity concentration, pH values, the amount of biomass and the light were studied. The uptake rate of radiocesium from the simulated waste solution is inversely proportional to the initial activity content and directly proportional to the increase in mass of plant and sunlight exposure. A spiked solution of pH Almost-Equal-To 4.9 was found to be the suitable medium for the treatment process. The uptake efficiency of {sup 137}Cs present with {sup 60}Co in mixed solution was higher than if it was present separately. On the contrary, uptake of {sup 60}Co is affected negatively by the presence of {sup 137}Cs in their mixed solution. Sunlight is the most required factor for the plant vitality and radiation resistance. The results of the present study indicated that water hyacinth may be a potential candidate plant of high concentration ratios (CR) for phytoremediation of radionuclides

  2. Development of an irradiation system for a small size continuous run multipurpose gamma irradiator; Desenvolvimento do sistema de irradiacao em um irradiador multiproposito de cobalto-60 tipo compacto

    Energy Technology Data Exchange (ETDEWEB)

    Calvo, Wilson Aparecido Parejo

    2005-07-01

    The Radiation Technology Center from Instituto de Pesquisas Energeticas e Nucleares (IPEN-CNEN/SP), Brazil, developed with a revolutionary design and national technology, a small size continuous run and multipurpose industrial gamma irradiator, to be used as a demonstration facility for manufacturers and contract service companies, which need economical and logistical in-house irradiation system alternatives. Also, to be useful for supporting the local scientific community on development of products and process using gamma radiation, assisting the traditional and potential users on process validation, training and qualification of operators and radioprotection officers. The developed technology for this facility consists of continuous tote box transport system, comprising a single concrete vault, where the automated transport system of products inside and outside of the irradiator utilizes a rotate door, integrated with the shielding, avoiding the traditional maze configuration. Covering 76 m{sup 2} of floor area, the irradiator design is product overlap sources and the maximum capacity of cobalt-60 wet sources is 37 P Bq (1 MCi). The performed quantification program of this multipurpose irradiator was based on AAMI/ISO 11137 standard, which recommends the inclusion of the following elements: installation and process quantification. The initial load of the multipurpose irradiator was 3.4 P Bq (92.1 k Ci) with 13 cobalt-60 sources model C-188, supplied by MDS Nordion Ion Technologies - Canada. For irradiator dose optimization, the source distribution was done using the software Cadgamma developed by IPEN-CNEN/SP. The poly-methylmethacrylate (PMMA) dosimeters system, certified by the International Dose Assurance Service (IDAS) of the International Atomic Energy Agency (IAEA) was used for irradiator dose mapping. The economic analysis, performance concerning to dose uniformity and cobalt-60 utilization efficiency were calculated and compared with other commercial

  3. Dysglycemia and Index60 as Prediagnostic End Points for Type 1 Diabetes Prevention Trials.

    Science.gov (United States)

    Nathan, Brandon M; Boulware, David; Geyer, Susan; Atkinson, Mark A; Colman, Peter; Goland, Robin; Russell, William; Wentworth, John M; Wilson, Darrell M; Evans-Molina, Carmella; Wherrett, Diane; Skyler, Jay S; Moran, Antoinette; Sosenko, Jay M

    2017-11-01

    We assessed dysglycemia and a T1D Diagnostic Index60 (Index60) ≥1.00 (on the basis of fasting C-peptide, 60-min glucose, and 60-min C-peptide levels) as prediagnostic end points for type 1 diabetes among Type 1 Diabetes TrialNet Pathway to Prevention Study participants. Two cohorts were analyzed: 1 ) baseline normoglycemic oral glucose tolerance tests (OGTTs) with an incident dysglycemic OGTT and 2 ) baseline Index60 <1.00 OGTTs with an incident Index60 ≥1.00 OGTT. Incident dysglycemic OGTTs were divided into those with (DYS/IND+) and without (DYS/IND-) concomitant Index60 ≥1.00. Incident Index60 ≥1.00 OGTTs were divided into those with (IND/DYS+) and without (IND/DYS-) concomitant dysglycemia. The cumulative incidence for type 1 diabetes was greater after IND/DYS- than after DYS/IND- ( P < 0.01). Within the normoglycemic cohort, the cumulative incidence of type 1 diabetes was higher after DYS/IND+ than after DYS/IND- ( P < 0.001), whereas within the Index60 <1.00 cohort, the cumulative incidence after IND/DYS+ and after IND/DYS- did not differ significantly. Among nonprogressors, type 1 diabetes risk at the last OGTT was greater for IND/DYS- than for DYS/IND- ( P < 0.001). Hazard ratios (HRs) of DYS/IND- with age and 30- to 0-min C-peptide were positive ( P < 0.001 for both), whereas HRs of type 1 diabetes with these variables were inverse ( P < 0.001 for both). In contrast, HRs of IND/DYS- and type 1 diabetes with age and 30- to 0-min C-peptide were consistent (all inverse [ P < 0.01 for all]). The findings suggest that incident dysglycemia without Index60 ≥1.00 is a suboptimal prediagnostic end point for type 1 diabetes. Measures that include both glucose and C-peptide levels, such as Index60 ≥1.00, appear better suited as prediagnostic end points. © 2017 by the American Diabetes Association.

  4. Very Luminous X-ray Point Sources in Starburst Galaxies

    Science.gov (United States)

    Colbert, E.; Heckman, T.; Ptak, A.; Weaver, K. A.; Strickland, D.

    Extranuclear X-ray point sources in external galaxies with luminosities above 1039.0 erg/s are quite common in elliptical, disk and dwarf galaxies, with an average of ~ 0.5 and dwarf galaxies, with an average of ~0.5 sources per galaxy. These objects may be a new class of object, perhaps accreting intermediate-mass black holes, or beamed stellar mass black hole binaries. Starburst galaxies tend to have a larger number of these intermediate-luminosity X-ray objects (IXOs), as well as a large number of lower-luminosity (1037 - 1039 erg/s) point sources. These point sources dominate the total hard X-ray emission in starburst galaxies. We present a review of both types of objects and discuss possible schemes for their formation.

  5. Nickel and cobalt release from children's toys purchased in Denmark and the United States.

    Science.gov (United States)

    Jensen, Peter; Hamann, Dathan; Hamann, Carsten R; Jellesen, Morten S; Jacob, Sharon E; Thyssen, Jacob P

    2014-01-01

    Nickel is the most common allergen detected by patch testing in children. There is an increasing number of cases in children who have not had exposure to piercing. Although the clinical relevance of nickel patch test reactions in children is sometimes uncertain, continued vigilance to identify new sources of nickel exposure in this age group is important. Recent case reports have described allergic nickel contact dermatitis in children following exposure to toys, but the magnitude of this problem is unknown. The aim of this study was to evaluate nickel and cobalt release from children's toys. We purchased 212 toys in 18 different retail and online stores in the United States and Denmark. Nickel and cobalt release was tested using the dimethylglyoxime and cobalt screening spot tests. A total of 73 toys (34.4%) released nickel, and none released cobalt. Toys are a commonly overlooked source of nickel exposure and sensitization. Therefore, dermatologists, allergists, and pediatricians should consider the role of toys in their evaluation of children with dermatitis, and the parents of children with positive nickel patch test reactions should be told that toys may release nickel and be a potential chemical source in the manifestation of allergic contact dermatitis.

  6. The effects of zinc on cobalt deposition in PWRs: summary report

    International Nuclear Information System (INIS)

    Bennet, Peter

    1996-01-01

    An experiment has been performed in a PWR loop of the Halden reactor to investigate the effects of the addition of 50 ppb zinc to the coolant on the incorporation of cobalt into the oxide films on primary circuit constructional materials. This report summarises the results from the three phases of the test. It was shown that zinc addition inhibits the corrosion of both new metal surfaces and surfaces with well-established oxides; this results in thinner oxide layers and reduced incorporation of cobalt into the oxide. Generally, there were no significant differences between the deposition of cobalt-60 onto pre-oxidised and new metal surfaces. In Phase 1 of the experiment, Co-60 deposition rates (normalised to the circulating Co-60 concentration) were lower than those measured in previous experiments in the loop by factors in the range from 5 to 10. In Phase 2, differences were observed in the behaviour of iron- and nickel-based alloys: larger decreases in the deposition rate compared with Phase 1 took place for stainless steel samples (i.e. factors > 20), whilst decreases on nickel-based coupons were generally less than a factor of 5. Co-60 deposition rates onto stainless steel coupons newly installed for Phase 3 of the experiment were greater by an order of magnitude than on coupons which had been exposed for all three phases; i.e. they were similar to those observed in Phase 1. The mechanisms by which zinc acts to inhibit corrosion and the incorporation of activity into oxide layers are not fully understood. More experimental data are required to resolve this issue, including information on the chemical form of the zinc within the oxide layer. (author)

  7. Comparative study of G2 delay and survival after /sup 241/Americium-. cap alpha. and /sup 60/Cobalt-. gamma. irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Luecke-Huhle, C.; Comper, W.; Hieber, L.; Pech, M.

    1982-06-01

    Survival and G2 delay following exposure to either /sup 60/Cobalt-..gamma..-rays or /sup 241/Americium-..cap alpha..-particles were studied in eight mammalian cell lines of human and animal origin including human fibroblasts from normal individuals and from patients with Ataxia telangiectasia or Fanconi's anemia. For both endpoints the effectiveness of alpha particle was greater as compared to ..gamma..-rays. RBE values for G2 delay (4.6-9.2) were in general comparable to RBE values derived from initial slopes of survival curves but higher compared to the ratio of mean inactivation doses. Ataxia cells were particularly sensitive to cell killing by ..gamma..-irradiation, however, showed average sensitivity to ..cap alpha..-particles of high LET. With the exception of Ataxia cells, cell killing and G2 delay seem to be related processes if individual cell cycle parameters are taken into account.

  8. Mitigation of cesium and cobalt contamination on the surfaces of RAM packages

    International Nuclear Information System (INIS)

    Krumhansl, J.; Bonhomme, F.; McConnell, P.; Kapoor, A.

    2004-01-01

    Techniques for mitigating the adsorption of 137 Cs and 60 Co on metal surfaces (e.g., RAM packages) exposed to contaminated water (e.g., spent-fuel pools) has been developed and experimentally verified. The techniques are also effective in removing some of the 60 Co and 137 Cs that may have been adsorbed on the surfaces after removal from the contaminated water. The principle for the 137 Cs mitigation technique is based upon ion-exchange processes. In contrast, 60 Co contamination primarily resides in minute particles of CRUD that become lodged on cask surfaces. CRUD is an insoluble Fe-Ni-Cr oxide that forms colloidal-sized particles as stainless steels corrode. Because of the similarity between Ni +2 and Co +2 , CRUD is able to scavenge and retain traces of cobalt as it forms. A number of organic compounds have a great specificity for combining with nickel and cobalt. Ongoing research is investigating the effectiveness of chemical complexing agent, EDTA, with regard to its ability to dissolve the host phase (CRUD) thereby liberating the entrained 60Co into a solution where it can be rinsed away

  9. 40 CFR 437.14 - New source performance standards (NSPS).

    Science.gov (United States)

    2010-07-01

    ... GUIDELINES AND STANDARDS THE CENTRALIZED WASTE TREATMENT POINT SOURCE CATEGORY Metals Treatment and Recovery....3 Metal Parameters Antimony 0.111 0.0312 Arsenic 0.0993 0.0199 Cadmium 0.782 0.163 Chromium 0.167 0.0522 Cobalt 0.182 0.0703 Copper 0.659 0.216 Lead 1.32 0.283 Mercury 0.000641 0.000246 Nickel 0.794 0...

  10. Cobalt oxide nanoparticle-modified carbon nanotubes as an ...

    Indian Academy of Sciences (India)

    of 60 mV were observed at. 100 mV s. −1 for CoOx−MWNT/GCE. An anodic peak at. 100 mV attributed to Co(II)/Co(III) redox transition associated with the electrode surface. The cathodic peak at 20 mV corre- spond to the reduction of various cobalt oxide species formed during the anodic sweep. The stability of the modified ...

  11. Cobalt, Linac, or Other: What Is the Best Solution for Radiation Therapy in Developing Countries?

    Energy Technology Data Exchange (ETDEWEB)

    Page, Brandi R., E-mail: bpage@wakehealth.edu [Wake Forest University Baptist Medical Center, Winston-Salem, North Carolina (United States); Hudson, Alana D.; Brown, Derek W. [Tom Baker Cancer Centre, University of Calgary, Calgary (Canada); Shulman, Adam C. [Overlook Medical Center, Summit, New Jersey (United States); Abdel-Wahab, May [Cleveland Clinic and Cleveland Clinic Lerner School of Medicine, Cleveland, Ohio (United States); Fisher, Brandon J. [Gamma West Cancer Services, Layton, Utah (United States); Radiating Hope, Midvale, Utah (www.radiatinghope.org) (United States); Patel, Shilpen [University of Washington, Seattle, Washington (United States)

    2014-07-01

    The international growth of cancer and lack of available treatment is en route to become a global crisis. With >60% of cancer patients needing radiation therapy at some point during their treatment course, the lack of available facilities and treatment programs worldwide is extremely problematic. The number of deaths from treatable cancers is projected to increase to 11.5 million deaths in 2030 because the international population is aging and growing. In this review, we present how best to answer the need for radiation therapy facilities from a technical standpoint. Specifically, we examine whether cobalt teletherapy machines or megavoltage linear accelerator machines are best equipped to handle the multitudes in need of radiation therapy treatment in the developing world.

  12. SU-F-T-375: Optimization of a New Co-60 Machine for Intensity Modulated Radiation Therapy: A Monte Carlo Characterization Study

    Energy Technology Data Exchange (ETDEWEB)

    Chibani, O; Fan, J; Tahanout, F; Eldib, A; Ma, C [Fox Chase Cancer Center, Philadelphia, PA (United States)

    2016-06-15

    Purpose: To provide a wide range of dose output for intensity modulation purposes while minimizing the beam penumbra for a new rotating cobalt therapy system. The highest dose rate needs to be maximized as well. Methods: The GEPTS Monte Carlo system is used to calculate the dose distribution from each tested Co-60 head for a wide range of field sizes (1×1 to 40×40 cm2). This includes the transport of photons (and secondary electrons) from the source through the collimation system (primary collimator, Y and × jaws, and MLCs) and finally in the water phantom. Photon transport includes Compton scattering (with electron binding effect), Rayleigh scattering, Photoelectric effect (with detailed simulation of fluorescence x-rays). Calculations are done for different system designs to reduce geometric penumbra and provide dose output modulation. Results: Taking into account different clinical requirements, the choice of a movable head (SAD = 70 to 80 cm) is made. The 120-leaf MLC (6-cm thick) entrance is at 32 cm from the bottom of the source (to reduce penumbra while allowing larger patient clearance). Three system designs (refereed here as S1–3) were simulated with different effective source sizes (2mm, 10mm and 17mm diameter). The effective point source is at mid-height of the 25-mm-long source. Using a 12000-Ci source, the designed Co-60 head can deliver a wide range of dose outputs (0.5 − 4 Gy/mn). A dose output of 2.2 Gy/mn can be delivered for a 10cm × 10cm field size with 1-cm penumbra using a 10mm effective source. Conclusion: A new 60Co-based VMAT machine is designed to meet different clinical requirements in term of dose output and beam penumbra. Outcomes from this study can be used for the design of 60Co machines for which a renewed interest is seen.

  13. Subcutaneous injection of sup 99m Tc pertechnetate at acupuncture points K-3 and B-60

    Energy Technology Data Exchange (ETDEWEB)

    Wu Chung-Chieng; Jong Shiang-Bin; Lin Chun-Ching; Chen Min-Fen; Chen Jong-Rern (Kaohsiung Medical Coll., Taiwan (China)); Chung Chieng

    1990-06-01

    The acupuncture points are known to be morphologically related to the nerves and vessels. Yet the physiological role of blood vessels in the formation of acupuncture points remains unknown. With subcutaneous injection of {sup 99m}Tc pertechnetate at the acupuncture points K-3 and B-60 and with intra-acupuncture point injection of {sup 99m}Tc pertechnetate at K-3 and B-60, a lower-limb venography like what was obtained by intravenous injection of {sup 99m}Tc macroaggregated albumin was demonstrated in the present study. It seems that some acupuncture points do play a role in drainage of tissue fluid from soft tissue into the veins. (author).

  14. Development of technology for the large-scale preparation of 60Co polymer film source

    International Nuclear Information System (INIS)

    Udhayakumar, J.; Pardeshi, G.S.; Gandhi, Shymala S.; Chakravarty, Rubel; Kumar, Manoj; Dash, Ashutosh; Venkatesh, Meera

    2008-01-01

    60 Co sources (∼37 kBq) in the form of a thin film are widely used in position identification of perforation in offshore oil-well explorations. This paper describes the large-scale preparation of such sources using a radioactive polymer containing 60 Co. 60 Co was extracted into chloroform containing 8-hydroxyquinoline. The chloroform layer was mixed with polymethyl methacrylate (PMMA) polymer. A large film was prepared using the polymer solution containing the complex. The polymer film was then cut into circular sources, mounted on a source holder and supplied to various users

  15. Family of Quantum Sources for Improving Near Field Accuracy in Transducer Modeling by the Distributed Point Source Method

    Directory of Open Access Journals (Sweden)

    Dominique Placko

    2016-10-01

    Full Text Available The distributed point source method, or DPSM, developed in the last decade has been used for solving various engineering problems—such as elastic and electromagnetic wave propagation, electrostatic, and fluid flow problems. Based on a semi-analytical formulation, the DPSM solution is generally built by superimposing the point source solutions or Green’s functions. However, the DPSM solution can be also obtained by superimposing elemental solutions of volume sources having some source density called the equivalent source density (ESD. In earlier works mostly point sources were used. In this paper the DPSM formulation is modified to introduce a new kind of ESD, replacing the classical single point source by a family of point sources that are referred to as quantum sources. The proposed formulation with these quantum sources do not change the dimension of the global matrix to be inverted to solve the problem when compared with the classical point source-based DPSM formulation. To assess the performance of this new formulation, the ultrasonic field generated by a circular planer transducer was compared with the classical DPSM formulation and analytical solution. The results show a significant improvement in the near field computation.

  16. Radiation accident of 60Co contamination. Mexico 1984

    International Nuclear Information System (INIS)

    1985-01-01

    The action taken to mitigate the consequences of a radiation accident occuring in the State of Chihuahua, Mexico, is described, when a no longer in use cobalt-60 teletherapy unit, with radioactive pellets still inside, was sold, unwittingly as ordinary scrap to be finally made into reinforced steel rods. The finished metallic items, unknowingly contaminated with cobalt-60, were subsequently sold in central and northern Mexico and in the United States of America. The junkyard, transport vehicle, several foundries and some streets of two cities and the road between them were also made radioactive by the accident. The discovery of and search for the radioactive metallic products is described as is their final disposal and the decontamination of the affected sites. Individual and collective radiation doses is estimated. (author)

  17. Effects of gamma radiation of Cobalt-60 on arabica and conillon seeds coffea: physic-chemistry evaluation

    International Nuclear Information System (INIS)

    Silva, Marcus Henriques da

    2012-01-01

    Brazil is the largest producer and exporter of coffee in the world. The coffee bean is one of the main products of the Brazilian trade balance. Two species of coffee are the most economically important: the Coffea arabica L. and Coffea canephora Pierre is the largest representative of the Coffea canephora Pierre is the coffea conillon. Food irradiation is an area of research that aims to increase the shelf life of foods and controlling pests. This study aimed to verify the physicochemical variables of Arabica coffee and conillon were affected when exposed to doses of gamma radiation from cobalt-60. The samples were provided by Polo in Coffee Quality Technology, Federal University of Lavras - UFLA. The coffee samples were subjected to irradiation doses: 0 (control), 5 kGy and 10 kGy, a multipurpose irradiator of IPEN - Research Institute of Nuclear Energy and the University of São Paulo, at a rate of 7.5 kGy / hour. For irradiation the samples were vacuum-packed in appropriate packaging aluminised. After the process of irradiation the samples were stored at a temperature of 15 ± 1 deg C and relative humidity of 17 ± 1%. The following analyzes were performed: levels of total sugars, glucose, sucrose, caffeine, humidity, pH, total acidity, electrical conductivity and fibers. Analyses were performed 1, 30, 60 and 90 days after irradiation, and the results were submitted to analysis of variance and means were compared by Tukey test at 5%. It was observed that the analysis results of the samples irradiated with 5 kGy and 10 kGy showed values similar to the control. It was concluded that irradiation did not induce deleterious effects on arabica coffee seeds and conillon irradiated with 5 kGy and 10 kGy to 90 days after irradiation. (author)

  18. Uptake of radionuclides caesium and cobalt

    International Nuclear Information System (INIS)

    Lukac, P.; Foldesova, M.

    1995-01-01

    By means of chemical treatment ammonium, potassium, sodium and H-form of zeolite were prepared. The chemical modifications of zeolite were carried out with: 2M solution of NaNO 3 , NH 4 NO 3 , KNO 3 ; 0,1M solution of HCl; NaOH solution of different concentration. The method of model radioactive solution was used to find the sorption ability for cesium and cobalt every modified zeolite. The model solution were 0.05M solution of cobalt labelled by 60 Co or cesium labelled by 137 Cs. The highest sorption ability was observed for zeolite modified by NaOH. The influence of pH on uptake of cesium and cobalt by modified zeolite was searched as well. The experimental data (leaching tests, compressive strength measurement and porosity) were measured for the case the Cs and Cs from model water solution and radioactive waste water were up taken on chemically modified zeolite and were subsequently incorporated into cement casts on blast furnace cement slags basis. The leachability was tested in water, in basis solution and in acid solution. The leachability in water and basic solution was negligible, in acid solution it was less than 4% which is inside of value of applied measure method. The compressive strength, porosity and leaching experiment are hopefully and show good mechanical stability and good retention of observed radionuclides in samples exposed in leaching solutions. (J.K.)

  19. Uptake of radionuclides caesium and cobalt

    Energy Technology Data Exchange (ETDEWEB)

    Lukac, P; Foldesova, M [Slovak Technical Univ., Bratislava (Slovakia)

    1996-12-31

    By means of chemical treatment ammonium, potassium, sodium and H-form of zeolite were prepared. The chemical modifications of zeolite were carried out with: 2M solution of NaNO{sub 3}, NH{sub 4}NO{sub 3}, KNO{sub 3}; 0,1M solution of HCl; NaOH solution of different concentration. The method of model radioactive solution was used to find the sorption ability for cesium and cobalt every modified zeolite. The model solution were 0.05M solution of cobalt labelled by {sup 60}Co or cesium labelled by {sup 137}Cs. The highest sorption ability was observed for zeolite modified by NaOH. The influence of pH on uptake of cesium and cobalt by modified zeolite was searched as well. The experimental data (leaching tests, compressive strength measurement and porosity) were measured for the case the Cs and Cs from model water solution and radioactive waste water were up taken on chemically modified zeolite and were subsequently incorporated into cement casts on blast furnace cement slags basis. The leachability was tested in water, in basis solution and in acid solution. The leachability in water and basic solution was negligible, in acid solution it was less than 4% which is inside of value of applied measure method. The compressive strength, porosity and leaching experiment are hopefully and show good mechanical stability and good retention of observed radionuclides in samples exposed in leaching solutions. (J.K.).

  20. Effect of vitamin B12 pulse addition on the performance of cobalt deprived anaerobic granular sludge bioreactors

    KAUST Repository

    Fermoso, Fernando G.; Bartacek, Jan; Lens, Piet N.L.

    2010-01-01

    The effect of a pulse addition of vitamin B12 as cobalt source to restore the performance of cobalt depleted methanol-fed bioreactors was investigated. One upflow anaerobic sludge bed (UASB) reactor was supplied with a pulse of vitamin B12, and its

  1. Calculation of dose for β point and sphere sources in soft tissue

    International Nuclear Information System (INIS)

    Sun Fuyin; Yuan Shuyu; Tan Jian

    1999-01-01

    Objective: To compare the results of the distribution of dose rate calculated by three typical methods for point source and sphere source of β nuclide. Methods: Calculating and comparing the distributions of dose rate from 32 P β point and sphere sources in soft tissue calculated by the three methods published in references, [1]. [2] and [3], respectively. Results: For the point source of 3.7 x 10 7 Bq (1mCi), the variations of the calculation results of the three formulas are within 10% if r≤0.35 g/cm 2 , r being the distance from source, and larger than 10% if r > 0.35 g/cm 2 . For the sphere source whose volume is 50 μl and activity is 3.7 x 10 7 Bq(1 mCi), the variations are within 10% if z≤0.15 g/cm 2 , z being the distance from the surface of the sphere source to a point outside the sphere. Conclusion: The agreement of the distributions of the dose rate calculated by the three methods mentioned above for point and sphere β source are good if the distances from point source or the surface of sphere source to the points observed are small, and poor if they are large

  2. X-ray imaging and spectroscopy of individual cobalt nanoparticles using photoemission electron microscopy

    International Nuclear Information System (INIS)

    Fraile Rodriguez, A.; Nolting, F.; Bansmann, J.; Kleibert, A.; Heyderman, L.J.

    2007-01-01

    Photoemission electron microscopy (PEEM) was employed for X-ray imaging and absorption spectroscopy of individual cobalt nanoparticles as small as 8 nm grown using an arc ion cluster source. Using lithographic markers on the samples we were able to identify the same particles with PEEM and scanning electron microscopy. Significant variations in the shape of the X-ray absorption spectra between different cobalt particles were detected. Furthermore, our data suggest that distinctive spectral information about the individual particles, such as the quenching of oxide-related features and changes in the cobalt L 3 -edge intensity, cancel out and cannot be detected in the measurement over an ensemble of particles

  3. Design of database management system for 60Co container inspection system

    International Nuclear Information System (INIS)

    Liu Jinhui; Wu Zhifang

    2007-01-01

    The function of the database management system has been designed according to the features of cobalt-60 container inspection system. And the software related to the function has been constructed. The database querying and searching are included in the software. The database operation program is constructed based on Microsoft SQL server and Visual C ++ under Windows 2000. The software realizes database querying, image and graph displaying, statistic, report form and its printing, interface designing, etc. The software is powerful and flexible for operation and information querying. And it has been successfully used in the real database management system of cobalt-60 container inspection system. (authors)

  4. Effects of cobalt-60 ionizing radiation on human erythrocyte and its membrane proteins

    International Nuclear Information System (INIS)

    Amancio, Francisco Fernandes

    1998-01-01

    Ionizing radiation has several uses, as sterilization and radiotherapy, by its effects on living beings. recently, it has been used, at relatively lower doses (25 Gy), on blood for transfusions, mainly to eliminate undesirable graft host reactions, for use in multi transfused or immunocompromised patients. Here, we study the effect of larger doses of cobalt-60 ionizing radiation (25-1600 Gy) on human erythrocytes, by cytometric, physiologic, biochemical and immunological methods, looking for its effects and its detection. The red cells presented a clear dose-dependent increase in this volume, when irradiated in doses higher than 200 Gy, more significant in stored blood, but without hemolysis. Osmotic fragility was increased only after irradiation of more than 400 Gy. By ektacytometry, there was a lower deformability of irradiated red cells, at low stress (0.3 Pa), similar to capillary flow, but without alteration in higher stress (3 Pa), found in cardiac chambers. By SDS-PAGE, it was demonstrated that irradiated isolated erythrocyte membranes had aggregation of spectrin molecules, and decay of bands with lower molecular mass. This effect could be attributed to the radiation-induced hydroxyl radical, by specific scavenger studies. Those modifications were both antigenic and immunogenic in experimental animals, and the induced antibodies recognizes, by ELISA and immunoblot, both native or irradiated membrane proteins. They recognize rather irradiated whole erythrocyte than native ones, by hemagglutination, indirect immunofluorescence or flow cytometry assays. Our data suggests that human red cells could be irradiated at higher doses than those usually employed, with possible effect on other contaminant pathogens, without loss of viability of its use in transfusions. After improvements, irradiation induced epitopes detection could be a new tool in biological dosimetry. (author)

  5. Effects of 60 Cobalt ionizing radiation in morphology and metabolism of yeasts and Chlamydospore of Candida albicans

    International Nuclear Information System (INIS)

    Grillo, Michel R.F.; Demicheli, Marina C.; Andrade Junior, Heitor F.; Galiesteo Junior, Andres A.J.

    2015-01-01

    Candida albicans is a fungus responsible for 80-90% of fungal infections, as the symptoms are similar to those of systemic bacterial infections there is a difficulty for immediate diagnosis. These difficulties can lead to delays of antifungal therapy, which contributes to the high mortality rates associated with this infection. Resistance structures referred to as chlamydospores are very common in the pathogen, representing different cell types that form in response to certain genetic or environmental conditions. Recently, various antifungal agents and new therapeutic strategies have come into use, allowing the fungus to acquire a resistance to the drugs. The use of ionizing radiation has been widely employed for the production of immunogens against various parasites. In this work, we evaluate the effects of gamma radiation ( 60 Co) in yeast and chlamydospore of C. albicans with doses ranging from 320 to 10.240 Gy with Cobalt 60. Subsequently the samples were plated and after seven days, the colony forming units (CFU) told. The viability of irradiated cells were evaluated using the Janus green dye. A dose of 6000 Gy was considered ideal for the mitigation of chlamydospore and yeast. The dimorphic change mechanisms of both fungal structures were not harmed. The viability of chlamydospores remained above 70% while the yeast viability remained above 85%. By transmission electron microscopy and fluorescence microscopy may be noted cytoplasmic changes, defects in the cell wall, mitochondria, and the presence of partially preserved vesicles of both morphological forms of C. albicans. Irradiation both chlamydospore as C. albicans yeast allows the suppression of their reproduction, opening the possibility of their use in future candidate immunogens. (author)

  6. Effects of 60 Cobalt ionizing radiation in morphology and metabolism of yeasts and Chlamydospore of Candida albicans

    Energy Technology Data Exchange (ETDEWEB)

    Grillo, Michel R.F.; Demicheli, Marina C.; Andrade Junior, Heitor F.; Galiesteo Junior, Andres A.J., E-mail: galisteo@usp.br [Universidade de Sao Paulo (IMTSP/USP), Sao Paulo, SP (Brazil). Instituto de Medicina Tropical. Lab. de Protozoologia; Takakura, Cleusa F.H. [Universidade de Sao Paulo (FM/USP), Sao Paulo, SP (Brazil). Departamento de Patologia de Molestias Transmissiveis. Lab. de Patologia; Negro, Gilda M.B. del [Universidade de Sao Paulo (HCFM/USP/IMTSP/LIM-53), Sao Paulo, SP (Brazil). Hospital das Clinicas. Lab. de Micologia; Nascimento, Nanci do [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2015-07-01

    Candida albicans is a fungus responsible for 80-90% of fungal infections, as the symptoms are similar to those of systemic bacterial infections there is a difficulty for immediate diagnosis. These difficulties can lead to delays of antifungal therapy, which contributes to the high mortality rates associated with this infection. Resistance structures referred to as chlamydospores are very common in the pathogen, representing different cell types that form in response to certain genetic or environmental conditions. Recently, various antifungal agents and new therapeutic strategies have come into use, allowing the fungus to acquire a resistance to the drugs. The use of ionizing radiation has been widely employed for the production of immunogens against various parasites. In this work, we evaluate the effects of gamma radiation ({sup 60}Co) in yeast and chlamydospore of C. albicans with doses ranging from 320 to 10.240 Gy with Cobalt 60. Subsequently the samples were plated and after seven days, the colony forming units (CFU) told. The viability of irradiated cells were evaluated using the Janus green dye. A dose of 6000 Gy was considered ideal for the mitigation of chlamydospore and yeast. The dimorphic change mechanisms of both fungal structures were not harmed. The viability of chlamydospores remained above 70% while the yeast viability remained above 85%. By transmission electron microscopy and fluorescence microscopy may be noted cytoplasmic changes, defects in the cell wall, mitochondria, and the presence of partially preserved vesicles of both morphological forms of C. albicans. Irradiation both chlamydospore as C. albicans yeast allows the suppression of their reproduction, opening the possibility of their use in future candidate immunogens. (author)

  7. Dosimetric Comparison of Real-Time MRI-Guided Tri-Cobalt-60 Versus Linear Accelerator-Based Stereotactic Body Radiation Therapy Lung Cancer Plans.

    Science.gov (United States)

    Wojcieszynski, Andrzej P; Hill, Patrick M; Rosenberg, Stephen A; Hullett, Craig R; Labby, Zacariah E; Paliwal, Bhudatt; Geurts, Mark W; Bayliss, R Adam; Bayouth, John E; Harari, Paul M; Bassetti, Michael F; Baschnagel, Andrew M

    2017-06-01

    Magnetic resonance imaging-guided radiation therapy has entered clinical practice at several major treatment centers. Treatment of early-stage non-small cell lung cancer with stereotactic body radiation therapy is one potential application of this modality, as some form of respiratory motion management is important to address. We hypothesize that magnetic resonance imaging-guided tri-cobalt-60 radiation therapy can be used to generate clinically acceptable stereotactic body radiation therapy treatment plans. Here, we report on a dosimetric comparison between magnetic resonance imaging-guided radiation therapy plans and internal target volume-based plans utilizing volumetric-modulated arc therapy. Ten patients with early-stage non-small cell lung cancer who underwent radiation therapy planning and treatment were studied. Following 4-dimensional computed tomography, patient images were used to generate clinically deliverable plans. For volumetric-modulated arc therapy plans, the planning tumor volume was defined as an internal target volume + 0.5 cm. For magnetic resonance imaging-guided plans, a single mid-inspiratory cycle was used to define a gross tumor volume, then expanded 0.3 cm to the planning tumor volume. Treatment plan parameters were compared. Planning tumor volumes trended larger for volumetric-modulated arc therapy-based plans, with a mean planning tumor volume of 47.4 mL versus 24.8 mL for magnetic resonance imaging-guided plans ( P = .08). Clinically acceptable plans were achievable via both methods, with bilateral lung V20, 3.9% versus 4.8% ( P = .62). The volume of chest wall receiving greater than 30 Gy was also similar, 22.1 versus 19.8 mL ( P = .78), as were all other parameters commonly used for lung stereotactic body radiation therapy. The ratio of the 50% isodose volume to planning tumor volume was lower in volumetric-modulated arc therapy plans, 4.19 versus 10.0 ( P guided tri-cobalt-60 radiation therapy is capable of delivering lung high

  8. Effect of dose fractionation of 60Co gamma radiation on longevity and reproduction of Sitophilus granarius (L., 1785) (Col., Curculionidae) in wheat

    International Nuclear Information System (INIS)

    Arthur, V.; Walder, J.M.M.; Wiendl, F.M.; Domarco, R.E.; Haddad, S.S.

    1987-01-01

    The effects of fractionated doses of gamma radiation in different interval of time on longevity and reproductivity of Sitophilus granarius (L., 1785) are studied. Gamma radiation was provided at dose rate of 1.56 kGy/hour by a Cobalt 60 source (Gammabeam-650). The insects were divided in two sets: one was irradiated at acute doses and the other in fractionated doses, with interval of 48 hours. Both sets received doses of 0,40, 50, 60, 70, 80, 90 and 100Gy. Mortality and and emergency were determined weekly. (M.A.C.) [pt

  9. Recovery of cobalt from spent lithium-ion batteries using supercritical carbon dioxide extraction.

    Science.gov (United States)

    Bertuol, Daniel A; Machado, Caroline M; Silva, Mariana L; Calgaro, Camila O; Dotto, Guilherme L; Tanabe, Eduardo H

    2016-05-01

    Continuing technological development decreases the useful lifetime of electronic equipment, resulting in the generation of waste and the need for new and more efficient recycling processes. The objective of this work is to study the effectiveness of supercritical fluids for the leaching of cobalt contained in lithium-ion batteries (LIBs). For comparative purposes, leaching tests are performed with supercritical CO2 and co-solvents, as well as under conventional conditions. In both cases, sulfuric acid and H2O2 are used as reagents. The solution obtained from the supercritical leaching is processed using electrowinning in order to recover the cobalt. The results show that at atmospheric pressure, cobalt leaching is favored by increasing the amount of H2O2 (from 0 to 8% v/v). The use of supercritical conditions enable extraction of more than 95wt% of the cobalt, with reduction of the reaction time from 60min (the time employed in leaching at atmospheric pressure) to 5min, and a reduction in the concentration of H2O2 required from 8 to 4% (v/v). Electrowinning using a leach solution achieve a current efficiency of 96% and a deposit with cobalt concentration of 99.5wt%. Copyright © 2016 Elsevier Ltd. All rights reserved.

  10. Applications and opportunities for radiation sources

    International Nuclear Information System (INIS)

    Round, K.J.

    1984-01-01

    An important spin-off benefit from the nuclear industry has been the ability to produce a wide variety of ionizing radiation sources for industrial, medical and scientific applications. These sources include radionuclides produced by irradiation of target material in reactors and cyclotrons or recovered from spent fuels, and accelerators. The uses of radiation in both medicine and industry can be expected to evolve. Traditional uses such as cancer therapy will mature and in some cases be displaced by new technology. Major new applications, including food processing and waste treatment, are expected to maintain the demand for isotopes such as cobalt 60 and to stimulate the development of economical and reliable accelerator systems. (L.L.) (Tab., 2 figs.)

  11. Thermomagnetic method to determine cobalt content in solid WC-Co alloys

    International Nuclear Information System (INIS)

    Tumanov, V.I.; Loshakov, A.L.; Korchakova, E.A.

    1980-01-01

    A thermomagnetic method of cobalt amount determination in tungsten solid alloys is suggested. The method consists in the following: a sample of solid alloy is placed in a magnetic field sufficient to achieve technical saturation (not less than 10 kOe), and specific magnetization of saturation of the alloy σ is determined, then the sample is heated and according to the curves of magnetic permeability dependence on the temperature the Curie point of the alloy THETA is determined and cobalt amount is calculated by the formula qsub(Co)=σ100/(kTHETA+b). The analysis duration is approximately 30 min. Comparative data of cobalt amount determination in solid alloys WC-Co using thermonagnetic and potentiometric methods are presented. Results obtained by thermomagnetic and chemical method are in good agreement. Efficiency of the thermomagnetic method is much higher

  12. Process and system to control manganese and cobalt isotopes deposits from the cooling fluid of a reactor

    International Nuclear Information System (INIS)

    Brehm, W.F.; McGuire, J.C.

    1978-01-01

    Process for controlling the deposition of manganese-54, cobalt-58 and cobalt-60 radionuclides on component surfaces, as from a liquid flow containing these nuclides and entering into contact with the surface of these components. It is characterised by the positioning of a getter forming substance in the liquid flow to collect these radionuclides on the getter forming substance which contains at least 73% nickel by weight [fr

  13. On the Deactivation of Cobalt-based Fischer-Tropsch Catalysts

    NARCIS (Netherlands)

    Cats, K.H.

    2016-01-01

    The Fischer-Tropsch Synthesis (FTS) process is an attractive way to obtain synthetic liquid fuel from alternative energy sources such as natural gas, coal or biomass. However, the deactivation of the catalyst, consisting of cobalt nanoparticles supported on TiO2, currently hampers the industrial

  14. X-ray Point Source Populations in Spiral and Elliptical Galaxies

    Science.gov (United States)

    Colbert, E.; Heckman, T.; Weaver, K.; Strickland, D.

    2002-01-01

    The hard-X-ray luminosity of non-active galaxies has been known to be fairly well correlated with the total blue luminosity since the days of the Einstein satellite. However, the origin of this hard component was not well understood. Some possibilities that were considered included X-ray binaries, extended upscattered far-infrared light via the inverse-Compton process, extended hot 107 K gas (especially in ellipitical galaxies), or even an active nucleus. Chandra images of normal, elliptical and starburst galaxies now show that a significant amount of the total hard X-ray emission comes from individual point sources. We present here spatial and spectral analyses of the point sources in a small sample of Chandra obervations of starburst galaxies, and compare with Chandra point source analyses from comparison galaxies (elliptical, Seyfert and normal galaxies). We discuss possible relationships between the number and total hard luminosity of the X-ray point sources and various measures of the galaxy star formation rate, and discuss possible options for the numerous compact sources that are observed.

  15. Cobalt Fischer-Tropsch catalysts: influence of cobalt dispersion and titanium oxides promotion

    Energy Technology Data Exchange (ETDEWEB)

    Azib, H

    1996-04-10

    The aim of this work is to study the effect of Sol-Gel preparation parameters which occur in silica supported cobalt catalysts synthesis. These catalysts are particularly used for the waxes production in natural gas processing. The solids have been characterized by several techniques: transmission electron microscopy (TEM), X-ray absorption near edge spectroscopy (XANES), programmed temperature reduction (TPR), infrared spectroscopy (IR), ultraviolet spectroscopy (UV), Magnetism, thermodesorption of H{sub 2} (TPD). The results indicate that the control of the cobalt dispersion and oxide phases nature is possible by modifying Sol-Gel parameters. The catalytic tests in Fischer-Tropsch synthesis were conducted on a pilot unit under pressure (20 atm) and suggested that turnover rates were independent of Co crystallite size, Co phases in the solids (Co deg., cobalt silicate) and titanium oxide promotion. On the other methane, the C{sub 3}{sup +} hydrocarbon selectivity is increased with increasing crystallite size. Inversely, the methane production is favoured by very small crystallites, cobalt silicate increase and titanium addition. However, the latter, used as a cobalt promoter, has a benefic effect on the active phase stability during the synthesis. (author). 149 refs., 102 figs., 71 tabs.

  16. Electroplated zinc-cobalt alloy

    International Nuclear Information System (INIS)

    Carpenter, D.E.O.S.; Farr, J.P.G.

    2005-01-01

    Recent work on the deposition and use of ectrodeposited zinc-cobalt alloys is surveyed. Alloys containing lower of Nuclear quantities of cobalt are potentially more useful. The structures of the deposits is related to their chemical and mechanical properties. The inclusion of oxide and its role in the deposition mechanism may be significant. Chemical and engineering properties relate to the metallurgical structure of the alloys, which derives from the mechanism of deposition. The inclusion of oxides and hydroxides in the electroplate may provide evidence for this mechanism. Electrochemical impedance measurements have been made at significant deposition potentials, in alkaline electrolytes. These reveal a complex electrode behaviour which depends not only on the electrode potential but on the Co content of the electrolyte. For the relevant range of cathodic potential zinc-cobalt alloy electrodeposition occurs through a stratified interface. The formation of an absorbed layer ZnOH/sup +/ is the initial step, this inhibits the deposition of cobalt at low cathodic potentials, so explaining its 'anomalous deposition'. A porous layer of zinc forms on the adsorbed ZnOH/sup +/ at underpotential. As the potential becomes more cathodic, cobalt co- deposits from its electrolytic complex forming a metallic solid solution of Co in Zn. In electrolytes containing a high concentration of cobalt a mixed entity (ZnCo)/sub +/ is assumed to adsorb at the cathode from which a CoZn intermetallic deposits. (author)

  17. Exclusive radiation therapy of endometrial carcinoma using HDR Co-60 and Cf-252 sources

    International Nuclear Information System (INIS)

    Inciura, A.; Janulionis, E.; Atkocius, V.

    2000-01-01

    Although the main treatment of endometrial cancer is surgery, the gross spread of carcinoma in pelvis, elderly age of the patients and serious therapeutical diseases do not allow to operate 20% of the patients. For these patients only radical treatment decision is the combined radiation therapy. However, using various modalities of combined radiotherapy, the treatment results are not satisfying: only 52% of patients survive 5 years. There was implemented a new method of combined radiotherapy, using a three-channel applicator with two-positional locating of HDR Co-60 radioactive sources (group I). A new method of brachytherapy for endometrial carcinoma using a HDR Cf 252 sources (group II) was implemented too. For group I the medium total dose of the point A was 77.6 Gy, point I - 69.6 Gy. point 2 - 84.2 Gy, point B - 52.6 Gy, For group II the medium total dose the points A, 3 and 4 was 50 iGy. For group I 1 year overaII survival rate was 85%, 3 year - 73%. The 3 year survival rate for stage I was 79%, for stage II - 89%, for stage III - 33%. 3 year survival for highly virulent tumours - 56% and for low virulent (adenocarcinoma) - 82% was statistically different. The loss of tumour differentiation correlated with the worse prognosis: 3 year survival for G1 and G2 tumours was 92%, for G3 - 45%. Low hemoglobin level was also associated with low survival rate: 2 year survival for Hb≥120g/l was 85% and Hb<120g/l - 23%. 1 year survival rate was 87%, 3 year - 66%, 5 year - 58% for group II, treated with Cf-252. Radiation complications occurred for 13.8% of the patients for group I and 6.2% for group II. Good survival rates and a small number of complications sufficiently proofed treatment method. (author)

  18. Bioremediation of 60Co from simulated spent decontamination solutions

    International Nuclear Information System (INIS)

    Rashmi, K.; Naga Sowjanya, T.; Maruthi Mohan, P.; Balaji, V.; Venkateswaran, G.

    2004-01-01

    Bioremediation of 60 Co from simulated spent decontamination solutions by utilizing different biomass of (Neurospora crassa, Trichoderma viridae, Mucor recemosus, Rhizopus chinensis, Penicillium citrinum, Aspergillus niger and, Aspergillus flavus) fungi is reported. Various fungal species were screened to evaluate their potential for removing cobalt from very low concentrations (0.03-0.16 μM) in presence of a high background of iron (9.33 mM) and nickel (0.93 mM) complexed with EDTA (10.3 mM). The different fungal isolates employed in this study showed a pickup of cobalt in the range 8-500 ng/g of dry biomass. The [Fe]/[Co] and [Ni]/[Co] ratios in the solutions before and after exposure to the fungi were also determined. At micromolar level the cobalt pickup by many fungi especially the mutants of N. crassa is seen to be proportional to the initial cobalt concentration taken in the solution. However, R. chinensis exhibits a low but iron concentration dependent cobalt pickup. Prior saturating the fungi with excess of iron during their growth showed the presence of selective cobalt pickup sites. The existence of cobalt specific sorption sites is shown by a model experiment with R. chinensis wherein at a constant cobalt concentration (0.034 μM) and varying iron concentrations so as to yield [Fe/Co] initial ratios in solution of 10, 100, 1000 and 287 000 have all yielded a definite Co pickup capacity in the range 8-47 ng/g. The presence of Cr(III)EDTA (3 mM) in solution along with complexed Fe and Ni has not influenced the cobalt removal. The significant feature of this study is that even when cobalt is present in trace level (sub-micromolar) in a matrix of high concentration (millimolar levels) of iron, nickel and chromium, a situation typically encountered in spent decontamination solutions arising from stainless steel based primary systems of nuclear reactors, a number of fungi studied in this work showed a good sensitivity for cobalt pickup

  19. The technological safety in facilities that manage radioactive sources

    International Nuclear Information System (INIS)

    Lizcano, D.

    2014-10-01

    The sealed radioactive sources are used inside a wide range of applications in the medicine, industry and investigation around the world. These sources can contain a great radionuclides variety, exhibiting a wide spectrum of activities and radiological half lives. This way, we can find pattern sources of radionuclides as Americium-241, Plutonium-238, Plutonium-239, Thorium-228 and Thorium-230, etc., with some activity of kBq in research laboratories, Iridium-192 and Cesium-137 sources used in brachytherapy with GBq activities, until sources with P Bq activities in industrial irradiators of Cobalt-60 and Cesium-137. This document approach the physical safety that entities like the IAEA recommends for the facilities that contain sealed sources, especially the measures that are taking in the Instituto Nacional de Investigaciones Nucleares (ININ) and others government facilities. (Author)

  20. Cobalt nanoparticles as recyclable catalyst for aerobic oxidation of alcohols in liquid phase

    Energy Technology Data Exchange (ETDEWEB)

    Mondal, Arijit; Mukherjee, Debkumar, E-mail: debkumarmukherjee@rediffmail.com [Ramsaday College, Department of Chemistry (India); Adhikary, Bibhutosh, E-mail: adhikarybibhu@yahoo.com [Indian Institute of Engineering, Sciences and Technology, Shibpur, Department of Chemistry (India); Ahmed, Md Azharuddin [University of Calcutta, Department of Physics (India)

    2016-05-15

    Cobalt nanoparticles prepared at room temperature from cobalt sulphate and tetrabutyl ammonium bromide as surfactant have been found to be effective oxidation catalysts. Palladium and platinum nanoparticles (average size 4–6 nm) can also be prepared from PdCl{sub 2} and K{sub 2}PtCl{sub 4}, respectively, using the same surfactant but require high temperature (~120 °C) and much longer preparation time. Agglomeration of nanoparticles prepared from metals like palladium and platinum in common solvents, however, restricts their use as catalysts. It is therefore our endeavour to find the right combination of catalyst and solvent that will be beneficial from industrial point of view. Magnetic property measurement of cobalt nanoclusters was made using SQUID to identify their reusability nature. Herein, we report the use of cobalt nanoparticles (average size 90–95 nm) in dichloromethane solvent as effective reusable catalysts for aerobic oxidation of a variety of alcohols.Graphical Abstract.

  1. Cobalt allergy in hard metal workers

    Energy Technology Data Exchange (ETDEWEB)

    Fischer, T; Rystedt, I

    1983-03-01

    Hard metal contains about 10% cobalt. 853 hard metal workers were examined and patch tested with substances from their environment. Initial patch tests with 1% cobalt chloride showed 62 positive reactions. By means of secondary serial dilution tests, allergic reactions to cobalt were reproduced in 9 men and 30 women. Weak reactions could not normally be reproduced. A history of hand eczema was found in 36 of the 39 individuals with reproducible positive test reactions to cobalt, while 21 of 23 with a positive initial patch test but negative serial dilution test had never had any skin problems. Hand etching and hand grinding, mainly female activities and traumatic to the hands, were found to involve the greatest risk of cobalt sensitization. 24 individuals had an isolated cobalt allergy. They had probably been sensitized by hard metal work, while the individuals, all women, who had simultaneous nickel allergy had probably been sensitized to nickel before their employment and then became sensitized to cobalt by hard metal work. A traumatic occupation, which causes irritant contact dermatitis and/or a previous contact allergy or atopy is probably a prerequisite for the development of cobalt allergy.

  2. Pharmacokinetics of inorganic cobalt and a vitamin B12 supplement in the Thoroughbred horse: Differentiating cobalt abuse from supplementation.

    Science.gov (United States)

    Hillyer, L L; Ridd, Z; Fenwick, S; Hincks, P; Paine, S W

    2018-05-01

    While cobalt is an essential micronutrient for vitamin B 12 synthesis in the horse, at supraphysiological concentrations, it has been shown to enhance performance in human subjects and rats, and there is evidence that its administration in high doses to horses poses a welfare threat. Animal sport regulators currently control cobalt abuse via international race day thresholds, but this work was initiated to explore means of potentially adding to application of those thresholds since cobalt may be present in physiological concentrations. To devise a scientific basis for differentiation between presence of cobalt from bona fide supplementation and cobalt doping through the use of ratios. Six Thoroughbred horses were given 10 mL vitamin B 12 /cobalt supplement (Hemo-15 ® ; Vetoquinol, Buckingham, Buckinghamshire, UK., 1.5 mg B 12 , 7 mg cobalt gluconate = 983 μg total Co) as an i.v. bolus then an i.v. infusion (15 min) of 100 mg cobalt chloride (45.39 mg Co) 6 weeks later. Pre-and post-administration plasma and urine samples were analysed for cobalt and vitamin B 12 . Urine and plasma samples were analysed for vitamin B 12 using an immunoassay and cobalt concentrations were measured via ICP-MS. Baseline concentrations of cobalt in urine and plasma for each horse were subtracted from their cobalt concentrations post-administration for the PK analysis. Compartmental analysis was used for the determination of plasma PK parameters for cobalt using commercially available software. On administration of a vitamin B 12 /cobalt supplement, the ratio of cobalt to vitamin B 12 in plasma rapidly increased to approximately 3 and then rapidly declined below a ratio of 1 and then back to near baseline over the next week. On administration of 100 mg cobalt chloride, the ratio initially exceeded 10 in plasma and then declined with the lower 95% confidence interval remaining above a ratio of 1 for 7 days. For two horses with extended sampling, the plasma ratio remained above one for

  3. Trans-Z-source Neutral Point Clamped inverter

    DEFF Research Database (Denmark)

    Mo, W.; Loh, P. C.; Li, D.

    2012-01-01

    Transformer based Z-source (trans-Z-source) inverters are recently proposed by extending the traditional Z-source inverter with higher buck-boost capability as well as reducing the passive components at the same time. Multi-Level Z-source inverters are single-stage topological solutions used...... for buck-boost energy conversion with all the favourable advantages of multi-level switching retained. This paper presents three-level trans-Z-source Neutral Point Clamped (NPC) inverter topology, which achieves both the advantages of trans-Z-source and three-level NPC inverter configuration. With proper...... modulation scheme, the three-level trans-Z-source inverter can function with minimum of six device commutations per half carrier cycle (same as the traditional buck NPC inverter), while maintaining to produce the designed volt-sec average and inductive voltage boosting at ac output terminals. The designed...

  4. COBALT SALTS PRODUCTION BY USING SOLVENT EXTRACTION

    Directory of Open Access Journals (Sweden)

    Liudmila V. Dyakova

    2010-06-01

    Full Text Available The paper deals with the extracting cobalt salts by using mixtures on the basis of tertiary amine from multicomponent solutions from the process of hydrochloride leaching of cobalt concentrate. The optimal composition for the extraction mixture, the relationship between the cobalt distribution coefficients and modifier’s nature and concentration, and the saltingout agent type have been determined. A hydrochloride extraction technology of cobalt concentrate yielding a purified concentrated cobalt solution for the production of pure cobalt salts has been developed and introduced at Severonikel combine.

  5. Calcium-assisted reduction of cobalt ferrite nanoparticles for nanostructured iron cobalt with enhanced magnetic performance

    International Nuclear Information System (INIS)

    Qi, B.; Andrew, J. S.; Arnold, D. P.

    2017-01-01

    This paper demonstrates the potential of a calcium-assisted reduction process for synthesizing fine-grain (~100 nm) metal alloys from metal oxide nanoparticles. To demonstrate the process, an iron cobalt alloy (Fe_6_6Co_3_4) is obtained by hydrogen annealing 7-nm cobalt ferrite (CoFe_2O_4) nanoparticles in the presence of calcium granules. The calcium serves as a strong reducing agent, promoting the phase transition from cobalt ferrite to a metallic iron cobalt alloy, while maintaining high crystallinity. Magnetic measurements demonstrate the annealing temperature is the dominant factor of tuning the grain size and magnetic properties. Annealing at 700 °C for 1 h maximizes the magnetic saturation, up to 2.4 T (235 emu/g), which matches that of bulk iron cobalt.

  6. Calcium-assisted reduction of cobalt ferrite nanoparticles for nanostructured iron cobalt with enhanced magnetic performance

    Energy Technology Data Exchange (ETDEWEB)

    Qi, B. [University of Florida, Interdisciplinary Microsystems Group, Department of Electrical and Computer Engineering (United States); Andrew, J. S. [University of Florida, Department of Materials Science and Engineering (United States); Arnold, D. P., E-mail: darnold@ufl.edu [University of Florida, Interdisciplinary Microsystems Group, Department of Electrical and Computer Engineering (United States)

    2017-03-15

    This paper demonstrates the potential of a calcium-assisted reduction process for synthesizing fine-grain (~100 nm) metal alloys from metal oxide nanoparticles. To demonstrate the process, an iron cobalt alloy (Fe{sub 66}Co{sub 34}) is obtained by hydrogen annealing 7-nm cobalt ferrite (CoFe{sub 2}O{sub 4}) nanoparticles in the presence of calcium granules. The calcium serves as a strong reducing agent, promoting the phase transition from cobalt ferrite to a metallic iron cobalt alloy, while maintaining high crystallinity. Magnetic measurements demonstrate the annealing temperature is the dominant factor of tuning the grain size and magnetic properties. Annealing at 700 °C for 1 h maximizes the magnetic saturation, up to 2.4 T (235 emu/g), which matches that of bulk iron cobalt.

  7. Performance of a C{sub 60}{sup +} ion source on a dynamic SIMS instrument

    Energy Technology Data Exchange (ETDEWEB)

    Fahey, Albert J. [Surface and Microanalysis Science Division, National Institute of Standards and Technology, 100 Bureau Dr. Stop 8371, Gaithersburg, MD 20899-8371 (United States)]. E-mail: albert.fahey@nist.gov; Gillen, Greg [Surface and Microanalysis Science Division, National Institute of Standards and Technology, 100 Bureau Dr. Stop 8371, Gaithersburg, MD 20899-8371 (United States); Chi, Peter [Surface and Microanalysis Science Division, National Institute of Standards and Technology, 100 Bureau Dr. Stop 8371, Gaithersburg, MD 20899-8371 (United States); Mahoney, Christine M. [Surface and Microanalysis Science Division, National Institute of Standards and Technology, 100 Bureau Dr. Stop 8371, Gaithersburg, MD 20899-8371 (United States)

    2006-07-30

    An IonOptika C{sub 60}{sup +} ion source has been fitted onto a CAMECA{sup 1} ims-4f. Stable ion beams of C{sub 60}{sup +} and C{sub 60}{sup 2+} have been obtained with typical currents approaching 20nA under conditions that allow for several days of source operation. The beam has been able to be focussed into a spot size of {approx}3{mu}m with an anode voltage of 10keV and scanning ion images have been acquired. We have performed analyses to characterize the performance of C{sub 60}{sup +} and C{sub 60}{sup 2+}. Depth profiles of a Cr-Ni multi-layer and polymer films with C{sub 60}{sup +} have produced excellent results. We have discovered that, under bombardment energies of <12keV on Si, C{sub 60}{sup +} will sputter material from the sample but will also produce deposition at a rate that exceeds the sputter rate. The performance of the source and our experiences with its operation will be discussed and some characteristic analysis data will be shown.

  8. Integrated Management Program for Radioactive Sealed Sources in Egypt IMPRSS

    International Nuclear Information System (INIS)

    Hasan, A.; El-Adham, K.

    2004-01-01

    Sealed sources are usually in capsules made of stainless steel. They are the size of a pen or a finger and contain one of hundreds of radioactive elements (e.g., Iridium, Radium) or their isotopes. They are air-tight and very durable, contain the radioactive material but not radiation. They are used in the health sector, industry, military, and universities. Incidents occurred in Met Halfa, Egypt, 2000 (Iridium-192); Goiania, Brazil, 1987 (Cesium-137); Mexico and Southwest U.S., 1977 -1984 (Cobalt-60); Peru, 1999 (Iridium-1992); Poland 2001 (Cobalt-60). The IMPRSS Mission is based on a joined partnership between the Egyptian Atomic Energy Authority, the Egyptian Ministry of Health, the Sandia National Laboratories, the International Atomic Energy Agency and others. The IMPRSS Mission protects human health and the environment in Egypt from mismanaged sealed sources, is developed jointly with MOH and EAEA, provides capabilities for managing radioactive sealed sources in Egypt, increases public awareness, provides education and training, improves emergency response capabilities, develops a permanent disposal facility, ensures the program is self-sustaining and ensures close coordination with the IAEA. Infrastructure how to manage sealed sources is discussed. It includes awareness, tracking and inventory control, security, recovery, conditioning and storage, recycling and disposal. Emergency response, regulatory reform, education and training and its targets are provided. The government of Egypt can protect the people of Egypt and is ready for emergencies. Prevention is the first line of defence and detection is the second line of defence. Adequate Emergency Response saves lives and adequate control reduces risk of mismanaged uses or deliberate misuses of sources. A Cradle-to-Grave approach is built on existing capabilities at EAEA and MOH

  9. Levels of cobalt and silver in water sources in a mining area in Ghana

    African Journals Online (AJOL)

    underground water and river water) from a mining community in Ghana. The water samples were treated in the laboratory by acid digestion and the concentration of silver and cobalt were analysed with Atomic Absorption Spectrophotometer.

  10. Analysis of point source size on measurement accuracy of lateral point-spread function of confocal Raman microscopy

    Science.gov (United States)

    Fu, Shihang; Zhang, Li; Hu, Yao; Ding, Xiang

    2018-01-01

    Confocal Raman Microscopy (CRM) has matured to become one of the most powerful instruments in analytical science because of its molecular sensitivity and high spatial resolution. Compared with conventional Raman Microscopy, CRM can perform three dimensions mapping of tiny samples and has the advantage of high spatial resolution thanking to the unique pinhole. With the wide application of the instrument, there is a growing requirement for the evaluation of the imaging performance of the system. Point-spread function (PSF) is an important approach to the evaluation of imaging capability of an optical instrument. Among a variety of measurement methods of PSF, the point source method has been widely used because it is easy to operate and the measurement results are approximate to the true PSF. In the point source method, the point source size has a significant impact on the final measurement accuracy. In this paper, the influence of the point source sizes on the measurement accuracy of PSF is analyzed and verified experimentally. A theoretical model of the lateral PSF for CRM is established and the effect of point source size on full-width at half maximum of lateral PSF is simulated. For long-term preservation and measurement convenience, PSF measurement phantom using polydimethylsiloxane resin, doped with different sizes of polystyrene microspheres is designed. The PSF of CRM with different sizes of microspheres are measured and the results are compared with the simulation results. The results provide a guide for measuring the PSF of the CRM.

  11. Cobalt nanoparticles as reusable catalysts for reduction of 4 ...

    Indian Academy of Sciences (India)

    33

    active and ordered structures of cobalt nanoparticles. The air stable ... same surfactant was found to reduce p-nitrophenol but lose their catalytic efficiency after recovery. Based on chemical and ... industrial sources.11-13 The US Environmental Protection Agency has reported nitrophenols as one of the most hazardous and ...

  12. Nickel acts as an adjuvant during cobalt sensitization

    DEFF Research Database (Denmark)

    Bonefeld, Charlotte Menne; Nielsen, Morten Milek; Vennegaard, Marie T.

    2015-01-01

    Metal allergy is the most frequent form of contact allergy with nickel and cobalt being the main culprits. Typically, exposure comes from metal-alloys where nickel and cobalt co-exist. Importantly, very little is known about how co-exposure to nickel and cobalt affects the immune system. We...... investigated these effects by using a recently developed mouse model. Mice were epicutaneously sensitized with i) nickel alone, ii) nickel in the presence of cobalt, iii) cobalt alone, or iv) cobalt in the presence of nickel, and then followed by challenge with either nickel or cobalt alone. We found...... that sensitization with nickel alone induced more local inflammation than cobalt alone as measured by increased ear-swelling. Furthermore, the presence of nickel during sensitization to cobalt led to a stronger challenge response to cobalt as seen by increased ear-swelling and increased B and T cell responses...

  13. Characteristics of large scale ionic source for JT-60

    Energy Technology Data Exchange (ETDEWEB)

    Fujiwara, Yukio; Honda, Atsushi; Inoue, Takashi [Japan Atomic Energy Research Inst., Naka, Ibaraki (Japan). Naka Fusion Research Establishment] [and others

    1997-02-01

    The Neutral Beam Injection (NBI) apparatus is expected for important role sharing apparatus to realize the plasma electric current drive and the plasma control in not only temperature upgrading of the plasma but also Tokamak nuclear fusion reactor for the next generation such as JT-60, ITER and so forth. Japan Atomic Energy Research Institute has developed the ionic source with high energy and large electric current for about 10 years. Some arrangement tests of the large negative ion source for JT-60 No. 1 were executed from June to October, 1995. As a series of arrangement tests, 400 KeV and 13.5 A of deuterium negative ion beam was successfully accelerated for 0.12 sec. under 0.22 Pa of low gas pressure. And, it was elucidated that electron electric current could be controlled efficiently even in deuterium negative ion beam. Here is described on the testing results in details. (G.K.)

  14. Concept for Risk-based Prioritisation of Point Sources

    DEFF Research Database (Denmark)

    Overheu, N.D.; Troldborg, Mads; Tuxen, N.

    2010-01-01

    estimates on a local scale from all the sources, and 3D catchment-scale fate and transport modelling. It handles point sources at various knowledge levels and accounts for uncertainties. The tool estimates the impacts on the water supply in the catchment and provides an overall prioritisation of the sites...

  15. 40 CFR 60.2035 - How are these new source performance standards structured?

    Science.gov (United States)

    2010-07-01

    ... standards structured? 60.2035 Section 60.2035 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... source performance standards contain the eleven major components listed in paragraphs (a) through (k) of this section. (a) Preconstruction siting analysis. (b) Waste management plan. (c) Operator training and...

  16. VCSEL sources for optical fiber-wireless composite data links at 60GHz

    DEFF Research Database (Denmark)

    Vegas Olmos, Juan José; Pang, Xiaodan; Lebedev, Alexander

    2013-01-01

    This paper presents a performance assessment of 60-GHz mm-wave signal generation using photonic upconversion employing a VCSEL as source. The system reaches 10−9 BER over a variety of optical fibers for data rates of 1.25-Gbit/s.......This paper presents a performance assessment of 60-GHz mm-wave signal generation using photonic upconversion employing a VCSEL as source. The system reaches 10−9 BER over a variety of optical fibers for data rates of 1.25-Gbit/s....

  17. Bioremediation of {sup 60}Co from simulated spent decontamination solutions

    Energy Technology Data Exchange (ETDEWEB)

    Rashmi, K.; Naga Sowjanya, T.; Maruthi Mohan, P.; Balaji, V.; Venkateswaran, G

    2004-07-26

    Bioremediation of {sup 60}Co from simulated spent decontamination solutions by utilizing different biomass of (Neurospora crassa, Trichoderma viridae, Mucor recemosus, Rhizopus chinensis, Penicillium citrinum, Aspergillus niger and, Aspergillus flavus) fungi is reported. Various fungal species were screened to evaluate their potential for removing cobalt from very low concentrations (0.03-0.16 {mu}M) in presence of a high background of iron (9.33 mM) and nickel (0.93 mM) complexed with EDTA (10.3 mM). The different fungal isolates employed in this study showed a pickup of cobalt in the range 8-500 ng/g of dry biomass. The [Fe]/[Co] and [Ni]/[Co] ratios in the solutions before and after exposure to the fungi were also determined. At micromolar level the cobalt pickup by many fungi especially the mutants of N. crassa is seen to be proportional to the initial cobalt concentration taken in the solution. However, R. chinensis exhibits a low but iron concentration dependent cobalt pickup. Prior saturating the fungi with excess of iron during their growth showed the presence of selective cobalt pickup sites. The existence of cobalt specific sorption sites is shown by a model experiment with R. chinensis wherein at a constant cobalt concentration (0.034 {mu}M) and varying iron concentrations so as to yield [Fe/Co]{sub initial} ratios in solution of 10, 100, 1000 and 287 000 have all yielded a definite Co pickup capacity in the range 8-47 ng/g. The presence of Cr(III)EDTA (3 mM) in solution along with complexed Fe and Ni has not influenced the cobalt removal. The significant feature of this study is that even when cobalt is present in trace level (sub-micromolar) in a matrix of high concentration (millimolar levels) of iron, nickel and chromium, a situation typically encountered in spent decontamination solutions arising from stainless steel based primary systems of nuclear reactors, a number of fungi studied in this work showed a good sensitivity for cobalt pickup.

  18. High-dose rate brachytherapy in the treatment of carcinoma of uterine cervix: twenty-year experience with cobalt after-loading system.

    Science.gov (United States)

    Mosalaei, A; Mohammadianpanah, M; Omidvari, S; Ahmadloo, N

    2006-01-01

    This retrospective analysis aims to report results of patients with cancer of uterine cervix treated with external-beam radiotherapy (EBR) and high-dose rate (HDR) brachytherapy, using manual treatment planning. From 1975 to 1995, 237 patients with FIGO stages IIB-IVA and mean age of 54.31 years were treated. EBR dose to the whole pelvis was 50 Gy in 25 fractions. Brachytherapy with HDR after-loading cobalt source (Cathetron) was performed following EBR completion with a dose of 30 Gy in three weekly fractions of 10 Gy to point A. Survival, local control, and genitourinary and gastrointestinal complications were assessed. In a median follow-up of 60.2 months, the 10-year overall and disease-free survival rate was 62.4%. Local recurrence was seen in 12.2% of patients. Distant metastases to the lymph nodes, peritoneum, lung, liver, and bone occurred in 25.3% of patients. Less than 6% of patients experienced severe genitourinary and/or gastrointestinal toxicity that were relieved by surgical intervention. No treatment-related mortality was seen. This series suggests that 50 Gy to the whole pelvis together with three fractions of 10 Gy to point A with HDR brachytherapy is an effective fractionation schedule in the treatment of locally advanced cancer of cervix. To decrease the complications, newer devices and treatment planning may be beneficial.

  19. The Sino-American belt study: nickel and cobalt exposure, epidemiology, and clinical considerations.

    Science.gov (United States)

    Hamann, Dathan; Hamann, Carsten; Li, Lin-Feng; Xiang, Hailian; Hamann, Kylin; Maibach, Howard; Taylor, James S; Thyssen, Jacob P

    2012-01-01

    Nickel and cobalt are common causes of metal allergy. The objective of this study was to investigate nickel and cobalt exposure in belt buckles by testing 701 belts purchased in China and the United States and to consider the prevalence of nickel allergy and its relevance among Chinese patients. Seven hundred one belt buckles purchased in China and the United States were tested for nickel and cobalt release. Six hundred thirty-one Chinese patients with suspected allergic contact dermatitis were patch tested and interviewed to determine clinical relevance of results. The Chinese and American literature was reviewed to investigate trends in nickel prevalence over the past decades. Sixty percent (n = 219) of belts purchased in China (n = 365) released nickel, and 0.5% (n = 2) released cobalt; 55.7% (n = 187) in the United States (n = 336) released nickel, and 0.9% (n = 3) released cobalt. Belt dermatitis was a significant clinical finding in 34.8% of Chinese nickel-allergic patients. Literature review suggests increasing nickel allergy prevalence in the United States and China. Metallic belt buckles are an important source of nickel exposure to consumers. Belts from lowest socioeconomic vendors were more likely to release nickel. Belts with silver color and dark metallic color were more likely to release nickel and cobalt, respectively. Clinical findings show belt dermatitis in China to be a problem.

  20. Cytogenetic characterization of low-dose hyper-radiosensitivity in Cobalt-60 irradiated human lymphoblastoid cells

    Energy Technology Data Exchange (ETDEWEB)

    Joshi, Gnanada S. [Department of Biological Sciences, Wayne State University, Detroit, MI 48202 (United States); Joiner, Michael C. [Department of Radiation Oncology, Wayne State University, Detroit, MI 48201 (United States); Tucker, James D., E-mail: jtucker@biology.biosci.wayne.edu [Department of Biological Sciences, Wayne State University, Detroit, MI 48202 (United States)

    2014-12-15

    Highlights: • Human cells were irradiated in G1 or G2 and evaluated for micronuclei and bridges. • Cells irradiated in G2 but not in G1 exhibit low dose hyper-radiosensitivity. • Response curves of cells irradiated in G2 do not fit a linear-no-threshold model. • Response curves of cells irradiated in G1 fit a linear-no-threshold model. - Abstract: The dose-effect relationships of cells exposed to ionizing radiation are frequently described by linear quadratic (LQ) models over an extended dose range. However, many mammalian cell lines, when acutely irradiated in G2 at doses ≤0.3 Gy, show hyper-radiosensitivity (HRS) as measured by reduced clonogenic cell survival, thereby indicating greater cell lethality than is predicted by extrapolation from high-dose responses. We therefore hypothesized that the cytogenetic response in G2 cells to low doses would also be steeper than predicted by LQ extrapolation from high doses. We tested our hypothesis by exposing four normal human lymphoblastoid cell lines to 0–400 cGy of Cobalt-60 gamma radiation. The cytokinesis block micronucleus assay was used to determine the frequencies of micronuclei and nucleoplasmic bridges. To characterize the dependence of the cytogenetic damage on dose, univariate and multivariate regression analyses were used to compare the responses in the low- (HRS) and high-dose response regions. Our data indicate that the slope of the response for all four cell lines at ≤20 cGy during G2 is greater than predicted by an LQ extrapolation from the high-dose responses for both micronuclei and bridges. These results suggest that the biological consequences of low-dose exposures could be underestimated and may not provide accurate risk assessments following such exposures.

  1. Electrocatalytic performance evaluation of cobalt hydroxide and cobalt oxide thin films for oxygen evolution reaction

    Science.gov (United States)

    Babar, P. T.; Lokhande, A. C.; Pawar, B. S.; Gang, M. G.; Jo, Eunjin; Go, Changsik; Suryawanshi, M. P.; Pawar, S. M.; Kim, Jin Hyeok

    2018-01-01

    The development of an inexpensive, stable, and highly active electrocatalyst for oxygen evolution reaction (OER) is essential for the practical application of water splitting. Herein, we have synthesized an electrodeposited cobalt hydroxide on nickel foam and subsequently annealed in an air atmosphere at 400 °C for 2 h. In-depth characterization of all the films using X-ray diffraction (XRD), X-ray photoelectron emission spectroscopy (XPS), field emission scanning electron microscopy (FE-SEM), electrochemical impedance spectroscopy (EIS) and linear sweep voltammetry (LSV) techniques, which reveals major changes for their structural, morphological, compositional and electrochemical properties, respectively. The cobalt hydroxide nanosheet film shows high catalytic activity with 290 mV overpotential at 10 mA cm-2 and 91 mV dec-1 Tafel slope and robust stability (24 h) for OER in 1 M KOH electrolyte compared to cobalt oxide (340 mV). The better OER activity of cobalt hydroxide in comparison to cobalt oxide originated from high active sites, enhanced surface, and charge transport capability.

  2. A method to analyze "source-sink" structure of non-point source pollution based on remote sensing technology.

    Science.gov (United States)

    Jiang, Mengzhen; Chen, Haiying; Chen, Qinghui

    2013-11-01

    With the purpose of providing scientific basis for environmental planning about non-point source pollution prevention and control, and improving the pollution regulating efficiency, this paper established the Grid Landscape Contrast Index based on Location-weighted Landscape Contrast Index according to the "source-sink" theory. The spatial distribution of non-point source pollution caused by Jiulongjiang Estuary could be worked out by utilizing high resolution remote sensing images. The results showed that, the area of "source" of nitrogen and phosphorus in Jiulongjiang Estuary was 534.42 km(2) in 2008, and the "sink" was 172.06 km(2). The "source" of non-point source pollution was distributed mainly over Xiamen island, most of Haicang, east of Jiaomei and river bank of Gangwei and Shima; and the "sink" was distributed over southwest of Xiamen island and west of Shima. Generally speaking, the intensity of "source" gets weaker along with the distance from the seas boundary increase, while "sink" gets stronger. Copyright © 2013 Elsevier Ltd. All rights reserved.

  3. Trans-Z-source and Γ-Z-source neutral-point-clamped inverters

    DEFF Research Database (Denmark)

    Wei, Mo; Loh, Poh Chiang; Blaabjerg, Frede

    2015-01-01

    Z-source neutral-point-clamped (NPC) inverters are earlier proposed for obtaining voltage buck-boost and three-level switching simultaneously. Their performances are, however, constrained by a trade-off between their input-to-output gain and modulation ratio. This trade-off can lead to high...

  4. Cobalt sensitization and dermatitis

    DEFF Research Database (Denmark)

    Thyssen, Jacob P

    2012-01-01

    : This clinical review article presents clinical and scientific data on cobalt sensitization and dermatitis. It is concluded that cobalt despite being a strong sensitizer and a prevalent contact allergen to come up on patch testing should be regarded as a very complex metal to test with. Exposure...

  5. Monte Carlo study of MLC fields for cobalt therapy machine

    Directory of Open Access Journals (Sweden)

    Komanduri M Ayyangar

    2014-01-01

    Full Text Available An automated Multi-Leaf Collimator (MLC system has been developed as add-on for the cobalt-60 teletherapy machines available in India. The goal of the present computational study is to validate the MLC design using Monte Carlo (MC modeling. The study was based on the Kirloskar-supplied Phoenix model machines that closely match the Atomic Energy of Canada Limited (AECL theratron-80 machine. The MLC is a retrofit attachment to the collimator assembly, with 14 non-divergent leaf pairs of 40 mm thick, 7 mm wide, and 150 mm long tungsten alloy plates with rounded edges and 20 mm tongue and 2 mm groove in each leaf. In the present work, the source and collimator geometry has been investigated in detail to arrive at a model that best represents the measured dosimetric data. The authors have studied in detail the proto-I MLC built for cobalt-60. The MLC field sizes were MC simulated for 2 × 2 cm 2 to 14 × 14 cm 2 square fields as well as irregular fields, and the percent depth dose (PDD and profile data were compared with ROPS† treatment planning system (TPS. In addition, measured profiles using the IMATRIXX system‡ were also compared with the MC simulations. The proto-I MLC can define radiation fields up to 14 × 14 cm΂ within 3 mm accuracy. The maximum measured leakage through the leaf ends in closed condition was 3.4% and interleaf leakage observed was 7.3%. Good agreement between MC results, ROPS and IMATRIXX results has been observed. The investigation also supports the hypothesis that optical and radiation field coincidence exists for the square fields studied with the MLC. Plots of the percent depth dose (PDD data and profile data for clinically significant irregular fields have also been presented. The MC model was also investigated to speed up the calculations to allow calculations of clinically relevant conformal beams.

  6. An aerial radiological survey of the Point Beach Nuclear Power Plant and surrounding area. Final report, October 19, 1996 - October 24, 1996

    International Nuclear Information System (INIS)

    Feimster, E.L.

    1997-12-01

    Radioactivity surrounding the Point Beach Nuclear Power Plant was measured using aerial radiological surveying techniques. The purpose of this survey was to document exposure rates and identify radiation sources within the survey area. The surveyed area included a 25-square-mile (65-square-kilometer) area, which encompasses the plant site. Data were acquired using an airborne detection system that employed sodium iodide, thallium-activated detectors. Exposure rates at 1 meter above ground level were computed from these data and plotted on a U.S. Geological Survey topographic map of the survey area. Several ground-based exposure-rate measurements were made for comparison with the aerial survey results. Exposure rates in areas surrounding the plant site varied (a) from 10-14 microroentgens per hour (μR/h) in cultivated fields, (b) from 8-10 μR/h in adjacent areas and along roadways, and (c) below 6 μR/h over waterways and wetland areas. Man-made radiation (102-202 μR/h) was found at the plant site; cobalt-60 was the primary source of activity found at the Point Beach site. No other detectable sources of man-made radioactivity were found. The exposure rates measured during this survey agreed well with those measured during the 1970 survey even though the survey methodology and parameters were significantly different

  7. Lethal dose determination of Cobalt-60 for adult Tribolium castaneum (Coleoptera: Tenebrionidae) and Cryptolestes ferrugineus (Coleoptera: Laemophloeidae)

    Energy Technology Data Exchange (ETDEWEB)

    Farias, Anderson Aparecido, E-mail: potenza@biologico.sp.gov.br [Instituto Biologico, Centro de Pesquisa e Desenvolvimento de Protecao Ambiental, Sao Paulo, SP (Brazil); Potenza, Marcos Roberto, E-mail: fcreis@usp.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil); Reis, Fabricio Caldeira; Sato, Mario Eidi, E-mail: mesato@biologico.sp.gov.br [Instituto Biologico, Centro Experimental Central, Laboratorio de Acarologia, Campinas, SP (Brazil)

    2015-07-01

    The insect infestation is a major problem in the grain storage. The pesticides are most widely used method for disinfestation and prevention. Treatment with gamma irradiation may increase the product shelf life without encountering formation of waste can be used in packaged foods and ready for commercialization, representing an important alternative to the use of pesticides. This study aimed to determine the immediate lethal dose of gamma radiation for adults of Tribolium castaneum and Cryptolestes ferrugineus. The study was conducted in the Instituto Biologico and the radiations held at the Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN, Sao Paulo city, using a multipurpose irradiator Cobalt-60 with 3.31 dose rate and 3.23 kGy in months of November/2014 and January/2015. Each experimental unit consisted of 20 adult insects, confined in a 10 mL polyethylene container. The experimental plots in number 10 per dose were subjected to increasing doses of gamma radiation: 0; 0.5; 0.75; 1.0; 1.25; 1.50; 1.75; 2.00; 2:50 and 3.00 kGy. Mortality was assessed within two to four hours after irradiation. The data were submitted to Probit analysis, using the POLO PLUS program. The LD90 to control 90% (LD90) to control adult Cryptolestes ferrugineus and Tribolium castaneum were 2.73 and 2.91 kGy, respectively. (author)

  8. Lethal dose determination of Cobalt-60 for adult Tribolium castaneum (Coleoptera: Tenebrionidae) and Cryptolestes ferrugineus (Coleoptera: Laemophloeidae)

    International Nuclear Information System (INIS)

    Farias, Anderson Aparecido; Potenza, Marcos Roberto; Reis, Fabricio Caldeira; Sato, Mario Eidi

    2015-01-01

    The insect infestation is a major problem in the grain storage. The pesticides are most widely used method for disinfestation and prevention. Treatment with gamma irradiation may increase the product shelf life without encountering formation of waste can be used in packaged foods and ready for commercialization, representing an important alternative to the use of pesticides. This study aimed to determine the immediate lethal dose of gamma radiation for adults of Tribolium castaneum and Cryptolestes ferrugineus. The study was conducted in the Instituto Biologico and the radiations held at the Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN, Sao Paulo city, using a multipurpose irradiator Cobalt-60 with 3.31 dose rate and 3.23 kGy in months of November/2014 and January/2015. Each experimental unit consisted of 20 adult insects, confined in a 10 mL polyethylene container. The experimental plots in number 10 per dose were subjected to increasing doses of gamma radiation: 0; 0.5; 0.75; 1.0; 1.25; 1.50; 1.75; 2.00; 2:50 and 3.00 kGy. Mortality was assessed within two to four hours after irradiation. The data were submitted to Probit analysis, using the POLO PLUS program. The LD90 to control 90% (LD90) to control adult Cryptolestes ferrugineus and Tribolium castaneum were 2.73 and 2.91 kGy, respectively. (author)

  9. The behaviour of cesium 137, chromium 51, cobalt 60, Manganese 54, sodium 22 and zinc 65 in simulated estuarine environments. Effects of suspended mineral particles and dissolved organic matters

    International Nuclear Information System (INIS)

    Mahler, P.

    1985-09-01

    This laboratory investigation studied the retention of 6 radionuclides (cesium 137, chrome 51, cobalt 60, manganese 54, sodium 22 and zinc 65) on three types of clay particles (kaolinite, illite, montmorillonite) and on sediments, suspended in media with salinities ranging between 0 and 34 per mill, with or without organic matters. Measurement of the radioactivity retained by the particles after 5 days' contact with the radionuclide made it possible to calculate the percentages retained and the distribution coefficients, and to follow their evolution versus salinity. Parallel experiments studied the behaviours of the 6 radionuclides as a function of experimental factors (wall effect, contact time..). An exhaustive bibliographic review gives the state-of-the-art of the knowledge. The following conclusions were derived: - the retention of all the radionuclides but chromium 51 decreased as soon as a low salinity appeared. Chromium (available as Cr 3+ ) precipitated quickly and strongly during fixation whatever the surfaces or the conditions: - as for the role of the clay type, illite showed a strong affinity for cesium 137; manganese 54 had a particular behaviour with montmorillonite that enhanced its precipitation into MnO 2 ; with cobalt, sodium and zinc, the percentages retained were always [fr

  10. Effect of vitamin B12 pulse addition on the performance of cobalt deprived anaerobic granular sludge bioreactors

    KAUST Repository

    Fermoso, Fernando G.

    2010-07-01

    The effect of a pulse addition of vitamin B12 as cobalt source to restore the performance of cobalt depleted methanol-fed bioreactors was investigated. One upflow anaerobic sludge bed (UASB) reactor was supplied with a pulse of vitamin B12, and its operation was compared to that of another cobalt depleted UASB reactor to which a pulse of CoCl2 was given. The addition of cobalt in the form of CoCl2 supplies enough cobalt to restore methanogenesis and maintain full methanol degradation coupled to methane production during more than 35 days after the CoCl2 pulse. Similar to CoCl2, pulse addition of vitamin B12 supplies enough cobalt to maintain full methanol degradation during more than 35 days after the pulse. However, the specific methanogenic activities (SMAs) of the sludge in the vitamin B12 supplied reactor were around 3 times higher than the SMA of the sludge from the CoCl2 supplied reactor at the same sampling times. An appropriate dosing strategy (repeated pulse dosing) combined with the choice of vitamin B12 as the cobalt species is suggested as a promising dosing strategy for methanol-fed anaerobic bioreactors limited by the micronutrient cobalt. © 2010 Elsevier Ltd. All rights reserved.

  11. Dosimetry characterization of the Tunisian Cobalt-60 gamma irradiation pilot plant for the irradiation of the mediterranean fruit fly

    International Nuclear Information System (INIS)

    Bettaieb, Nasreddine; Farah, Kaled; Kadri, Omrane; Jerbi, Taieb; Gharbi, Foued; Manai, Kais

    2005-01-01

    Cobalt-60 gamma irradiation pilot plant has been put into operation in 1999 at the National Center for nuclear scinces and technologies, Sidi-Thabet, Tunisia. An initial characterization of this pilot was performed to determine the overall performance of the irradiator in delivering absorbed dose to a product prior to routine processing, in particular sterilisation of medical devices and food irradiation. A new irradiation holder was recently installed; it was designed especially for the irradiation of pupae of the Meditterranean fruit fly. It consists of four turn plates which makes it possible to rotate the canisters holding the pupae within the radiation field. The axis of ratation is vertical and parallel to the source pencils. Prior to routine irradiation using the new irradiation holder, validation procedures are necessary to establish conditions of the irradiation within the specification. In the course of these procedures, detailed dose mapping on a vertical plane in the middel of the canister of insect pupae with bulk density of 0.446 g /cm3 was carried out for two irradiation configurations : fixed plates and turned plates. GafChromic dosimeter calibrated against Alanine / ESR dosimetry system was used for the dose measurements. The maximum and minimum dose locations were determined and the dose uniformity ratio calculated and discussed. Detailed analyses of the isodose curves and histogram of the frequency distribution of absorbed dose were also given. Transit dose and dose rate in the reference position inside the canister were measured using Fricke dosimeters. The results of measurements of absorbed dose and dose distribution in insect pupae do not show any significant difference in the dose uniformity ratio (U=Dmax / Dmin) between the two irradiation configurations. At the same time we observed with turned plates configuration an improvement of the homogeneity of the absorbed dose distribution in the insect pupae showed by the increasing of the pipae

  12. BEAMLINE-CONTROLLED STEERING OF SOURCE-POINT ANGLE AT THE ADVANCED PHOTON SOURCE

    Energy Technology Data Exchange (ETDEWEB)

    Emery, L.; Fystro, G.; Shang, H.; Smith, M.

    2017-06-25

    An EPICS-based steering software system has been implemented for beamline personnel to directly steer the angle of the synchrotron radiation sources at the Advanced Photon Source. A script running on a workstation monitors "start steering" beamline EPICS records, and effects a steering given by the value of the "angle request" EPICS record. The new system makes the steering process much faster than before, although the older steering protocols can still be used. The robustness features of the original steering remain. Feedback messages are provided to the beamlines and the accelerator operators. Underpinning this new steering protocol is the recent refinement of the global orbit feedback process whereby feedforward of dipole corrector set points and orbit set points are used to create a local steering bump in a rapid and seamless way.

  13. Isotropic irradiation of detectors from point sources

    DEFF Research Database (Denmark)

    Aage, Helle Karina

    1997-01-01

    NaI(Tl) scintillator detectors have been exposed to gamma rays from 8 different point sources from different directions. Background and backscatter of gamma-rays from the surroundings have been subtracted in order to produce clean spectra. By adding spectra obtained from exposures from different ...

  14. Hydrothermal synthesis and characterization of sea urchin-like nickel and cobalt selenides nanocrystals

    Energy Technology Data Exchange (ETDEWEB)

    Liu Xiaohe [Department of Inorganic Materials, Central South University, Changsha, Hunan 410083 (China) and School of Metallurgical Science and Engineering, Central South University, Changsha, Hunan 410083 (China)]. E-mail: liuxh@mail.csu.edu.cn; Zhang Ning [Department of Inorganic Materials, Central South University, Changsha, Hunan 410083 (China); Yi Ran [Department of Inorganic Materials, Central South University, Changsha, Hunan 410083 (China); Qiu Guanzhou [Department of Inorganic Materials, Central South University, Changsha, Hunan 410083 (China); Yan Aiguo [Department of Inorganic Materials, Central South University, Changsha, Hunan 410083 (China); Wu Hongyi [Department of Inorganic Materials, Central South University, Changsha, Hunan 410083 (China); Meng Dapeng [Department of Inorganic Materials, Central South University, Changsha, Hunan 410083 (China); Tang, Motang [School of Metallurgical Science and Engineering, Central South University, Changsha, Hunan 410083 (China)

    2007-05-25

    Sea urchin-like nanorod-based nickel and cobalt selenides nanocrystals have been selective synthesized via a hydrothermal reduction route in which hydrated nickel chloride and hydrated cobalt chloride were employed to supply Ni and Co source and aqueous hydrazine (N{sub 2}H{sub 4}.H{sub 2}O) was used as reducing agent. The composition, morphology, and structure of final products could be easily controlled by adjusting the molar ratios of reactants and process parameters such as hydrothermal time. The morphology and phase structure of the final products have been investigated by X-ray diffraction, transmission electron microscopy, and scanning electron microscopy. The probable formation mechanism of the sea urchin-like nanorod-based nickel and cobalt selenides nanocrystals was discussed on the basis of the experimental results.

  15. Thermal Analysis of a Cracked Half-plane under Moving Point Heat Source

    Directory of Open Access Journals (Sweden)

    He Kuanfang

    2017-09-01

    Full Text Available The heat conduction in half-plane with an insulated crack subjected to moving point heat source is investigated. The analytical solution and the numerical means are combined to analyze the transient temperature distribution of a cracked half-plane under moving point heat source. The transient temperature distribution of the half plane structure under moving point heat source is obtained by the moving coordinate method firstly, then the heat conduction equation with thermal boundary of an insulated crack face is changed to singular integral equation by applying Fourier transforms and solved by the numerical method. The numerical examples of the temperature distribution on the cracked half-plane structure under moving point heat source are presented and discussed in detail.

  16. Determination of dosimetric parameters of Asymmetric fields from those of Symmetric fields for equinox 100 Cobalt-60 teletherapy machine

    International Nuclear Information System (INIS)

    Mensah, K.

    2014-07-01

    The Theratron Equinox 100 Cobalt-60 therapy unit is equipped wtih x-ray collimators or jaws that can be moved independently or allow asymmetric fields with field centres positioned away from the true central axis of the beam. Although asymmetric collimation can be performed by beam splitters or secondary blocking on a shadow tray; an independent jaw feature reduces the set-up time and spares the therapist from handling heavy blocks. Clinical sites where asymmetric jaws are typically used include breast, head and neck, craniospinal and prostate. Knowledge of the dose distribution of asymmetric fields is required to help evaluate the dosimetry of this non-standard treatment delivery technique prior to clinical implementation. IBA StarTrack 2-D array was used to acquire beam profiles of symmetric and asymmetric beams of different field sizes and varying depth using the Theratron Equinox 100 Cobalt-60 teletherapy unit. The 2-D water phantom was then used to measure PDDs and output factors of both the symmetric and asymmetric beams at varying depths and field sizes. The off-axis ratio was also determined from the half beam profile of the largest field size of the treatment machine and then the output factor ratios were used to validate it. The treatment planning system was then used to model both the symmetric and asymmetic beams and the PDDs and output factors were also calculated. Beam profiles for asymmetry beams showed good agreement with symmetry beam profiles for smaller field sizes and the deviations among them steadily became more evident with increasing field sizes. This difference in the dose distribution for asymmetric fields compared to the dose distribution for symmetric fields was due to the tilt of the dose profiles towards the beam axis. This tilt in the dose profiles of the asymmetic beams was caused by the oblique incidence of the asymmetric beam at off-axis locations, causing less beam hardening compared to that along the central axis. In treatment

  17. Activation measurements for thermal neutrons. Part A. Cobalt (60Co) activation

    International Nuclear Information System (INIS)

    Kerr, George D.; Shizuma, Kiyoshi; Endo, Satoru; Maruyama, Takashi; Cullings, Harry M.; Komura, Kazuhisa; Okumura, Yutaka; Egbert, Stephen D.

    2005-01-01

    The 60 Co measurements at Hiroshima and Nagasaki were reviewed and compared with the results of the new DS02 calculations for the two cities. Some corrections were made to previously published data from the 1965 measurements of JNIRS, ground ranges of all of the 60 Co measurements were reviewed and new ground ranges were determined when possible by transforming sample coordinates to the new city maps for Hiroshima and Nagasaki, and transmission factors were investigated for a number of samples used in the 60 Co measurements. Transmission factors were not calculated for all samples used in the 60 Co measurements but some general rules were given for estimating transmission factors for these samples. Experimental measurements of the background 60 Co activity from environmental neutrons were also reviewed, and it was found that the 60 Co background from environmental neutrons was not an important factor in the 60 Co measurements of bomb-induced activity at either city. (J.P.N.)

  18. Germanium detector calibration according to the standard NF M 60-810 without using radioactive sources

    Energy Technology Data Exchange (ETDEWEB)

    Duda, J. M.; Garell, I.; Losset, Y.; Vichot, L. [CEA de Valduc, Service de Protection Contre Les Rayonnements, 21110 Is sur Tille (France); Chazalet, J.; Tauvel, Y.; Poulet, F. [IUP Genie des Systemes Industriels, Universite Blaise Pascal, Departement de Physique, 24 avenue des Landais, 63177 Aubiere Cedex (France)

    2009-07-01

    In-situ gamma ray spectrometry is used to determine the specific activities of natural and artificial radioactive nuclides in the soil with a good accuracy. This method is very interesting for environmental measurements and leads to soil determination activity. It is a cheaper method than analysis of great amounts of soil samples in the laboratory. As there is no standard soil, detection efficiency can be estimated using either statistical tools or combination of radioactive point sources calibration thanks to mathematical models of NF-M-60-810 standard representing the radionuclide distribution in soil. Experimental determination of detection efficiency requires a large number of operations involving the handling of radioactive standards in the energy range from 0.06 - 2 MeV. For these reasons, detection efficiency model has been determined without using radioactive sources. In order to reduce analytical time and to simplify the efficiency detector calibration, it is possible to associate numerical and deterministic methods and to get a relative accuracy below 25 per cent

  19. Impurity diffusion of cobalt in plutonium

    International Nuclear Information System (INIS)

    Charissoux, Christian; Calais, Daniel.

    1975-01-01

    The sectioning method for investigation of the impurity diffusion of 60 Co in the fcc and bcc phases of plutonium gives the following results: 344-426 deg C: D=1.2x10 -2 exp(-12700/RT)cm 2 /s in delta Pu(fcc); 484-621 deg C: D=1.4x10 -3 exp(-9900/RT)cm 2 /s in epsilon Pu(bcc). Cobalt is a fast diffuser in plutonium; the diffusion coefficient being unaffected by phase changes delta'→delta; delta'→epsilon, the diffusion mechanism is probably dissociative in both phases, the solute becoming interstitial by: solute (substitution) reversible solute (interstitial) + vacancy [fr

  20. Nitrogen-doped carbon-supported cobalt-iron oxygen reduction catalyst

    Science.gov (United States)

    Zelenay, Piotr; Wu, Gang

    2014-04-29

    A Fe--Co hybrid catalyst for oxygen reaction reduction was prepared by a two part process. The first part involves reacting an ethyleneamine with a cobalt-containing precursor to form a cobalt-containing complex, combining the cobalt-containing complex with an electroconductive carbon supporting material, heating the cobalt-containing complex and carbon supporting material under conditions suitable to convert the cobalt-containing complex and carbon supporting material into a cobalt-containing catalyst support. The second part of the process involves polymerizing an aniline in the presence of said cobalt-containing catalyst support and an iron-containing compound under conditions suitable to form a supported, cobalt-containing, iron-bound polyaniline species, and subjecting said supported, cobalt-containing, iron bound polyaniline species to conditions suitable for producing a Fe--Co hybrid catalyst.

  1. Synthesis of new cobalt aluminophosphate framework by opening a cobalt methylphosphonate layered material

    Czech Academy of Sciences Publication Activity Database

    Zaarour, M.; Pérez, O.; Boullay, P.; Martens, J.; Mihailova, B.; Karaghiosoff, K.; Palatinus, Lukáš; Mintova, S.

    2017-01-01

    Roč. 19, č. 34 (2017), s. 5100-5105 ISSN 1466-8033 Institutional support: RVO:68378271 Keywords : cobalt aluminophosphate * cobalt methylphosphonate * layered materials * crystallic structure * X-ray diffraction Subject RIV: BM - Solid Matter Physics ; Magnetism OBOR OECD: Condensed matter physics (including formerly solid state physics, supercond.) Impact factor: 3.474, year: 2016

  2. Sorption behaviour of cobalt-60 on Suez Canal bottom sediments

    International Nuclear Information System (INIS)

    Abdel Gawad, S.A.; El-Shinawy, R.M.K.; Abdel Malik, W.E.Y.

    1981-01-01

    Mineralogical, elemental analysis and sorption behaviour of the Suez Canal bottom sediments in the Port Said area were investigated. It was found that the bottom sediment consist mainly of quartz, feldspars and traces of calcite mineral. The cation-exchange capacity was found to increase as the particle size of the sediment decreased. Sorption of 60 Co by the bottom sediment increased with contact time up to 6 h. Variation of the solution pH from 4 to 9 showed limited increase in the sorption of 60 Co. As carrier concentrations increase from 10 -7 N to 10 -3 N, sorption of Co was found to increase linearly following Freundlich isotherm. The presence of Mg 2+ and Fe 3+ in solution depressed the sorption of 60 Co by the sediments. The desorption of 60 Co from bottom sediment with distilled and Suez Canal water was found to increase with contact time. (author)

  3. Molecular mechanics calculations on cobalt phthalocyanine dimers

    NARCIS (Netherlands)

    Heuts, J.P.A.; Schipper, E.T.W.M.; Piet, P.; German, A.L.

    1995-01-01

    In order to obtain insight into the structure of cobalt phthalocyanine dimers, molecular mechanics calculations were performed on dimeric cobalt phthalocyanine species. Molecular mechanics calculations are first presented on monomeric cobalt(II) phthalocyanine. Using the Tripos force field for the

  4. AN ELECTROPLATING METHOD OF FORMING PLATINGS OF NICKEL, COBALT, NICKEL ALLOYS OR COBALT ALLOYS

    DEFF Research Database (Denmark)

    1997-01-01

    An electroplating method of forming platings of nickel, cobalt, nickel alloys or cobalt alloys with reduced stresses in an electrodepositing bath of the type: Watt's bath, chloride bath or a combination thereof, by employing pulse plating with periodic reverse pulse and a sulfonated naphthalene...

  5. Degradation of the insecticide ethyl parathion in different environmental matrices by gamma radiation from Cobalt-60

    International Nuclear Information System (INIS)

    Luchini, Luiz Carlos

    1995-01-01

    This work studies the use of gamma radiation from cobalt-60 to induce parathion degradation in different matrices, as well as, quantified GC-NPD and identified by GC-MS, the radiolysis resulting products. Results show that the insecticide was completely degraded in aqueous solution after treatment with 1.0 kGy dosis in a dosis rate of 3.12 kGy h -1 . In methanol, parathion was completely degraded only with 30 kGy at 3.12 kGy h -1 . The metabolites detected after radiolysis were the same formed by biological degradation, i.e, p-nitrophenol, p-aminophenol, paraoxon and aminoparathion. The gamma radiation also degraded paraoxon which is the most toxic metabolite of parathion. It was verified that, not only the total radiation, but also the dosis rate supplied to the aqueous solution had a significant effect on the insecticide degradation, and the formation of metabolites occurred in a selective way respecting the dosis and dosis rate. Otherwise, the gamma radiation did almost not degraded the parathion adsorbed in solid matrices as rice, moist and dry soil, even using dosis of 5,30 and 50 kGy, respectively. The parathion yield and the dosis of gamma radiation needed for 50% reduction of the insecticide initial concentration in aqueous solution were also calculated and presented. Thus, it was verified that irradiation of parathion besides to be an important instrument for environmental decontamination of this pesticide in aqueous matrix, it allows the production of parathion metabolites for ecotoxicological studies. (author)

  6. Deposition and properties of cobalt- and ruthenium-based ultra-thin films

    Science.gov (United States)

    Henderson, Lucas Benjamin

    Future copper interconnect systems will require replacement of the materials that currently comprise both the liner layer(s) and the capping layer. Ruthenium has previously been considered as a material that could function as a single material liner, however its poor ability to prevent copper diffusion makes it incompatible with liner requirements. A recently described chemical vapor deposition route to amorphous ruthenium-phosphorus alloy films could correct this problem by eliminating the grain boundaries found in pure ruthenium films. Bias-temperature stressing of capacitor structures using 5 nm ruthenium-phosphorus film as a barrier to copper diffusion and analysis of the times-to-failure at accelerated temperature and field conditions implies that ruthenium-phosphorus performs acceptably as a diffusion barrier for temperatures above 165°C. The future problems associated with the copper capping layer are primarily due to the poor adhesion between copper and the current Si-based capping layers. Cobalt, which adheres well to copper, has been widely proposed to replace the Si-based materials, but its ability to prevent copper diffusion must be improved if it is to be successfully implemented in the interconnect. Using a dual-source chemistry of dicobaltoctacarbonyl and trimethylphosphine at temperatures from 250-350°C, amorphous cobalt-phosphorus can be deposited by chemical vapor deposition. The films contain elemental cobalt and phosphorus, plus some carbon impurity, which is incorporated in the film as both graphitic and carbidic (bonded to cobalt) carbon. When deposited on copper, the adhesion between the two materials remains strong despite the presence of phosphorus and carbon at the interface, but the selectivity for growth on copper compared to silicon dioxide is poor and must be improved prior to consideration for application in interconnect systems. A single molecule precursor containing both cobalt and phosphorus atoms, tetrakis(trimethylphosphine)cobalt

  7. Nanocrystalline Iron-Cobalt Alloys for High Saturation Indutance

    Science.gov (United States)

    2016-02-24

    film deposited just like the pick-up of a turn-table music player. The contact pads provide the electrical contacts to the starting and end point of...anisotropy using the geometry of the thin toroid. We have shown experimentally that the thin film toroid calculations may be applicable to up to millimeter...thin film as well as bulk devices. 15. SUBJECT TERMS Micromagnetic Calculations, Nanocrystalline cobalt-iron, Thin Film Toroids 16. SECURITY

  8. Disinfestation of export oranges and tangerines (Citrus spp) against medfly Ceratitis capitata (Wied., 1824) (Diptera; Tephritidae) by gamma irradiation (Co-60)

    International Nuclear Information System (INIS)

    Costa, N.

    1990-01-01

    A gamma bean 650 cobalt-60 source was utilized for irradiation (0; 10; 50; 100; 200; 300; 400; 500; 750 and 1000 Gy) of fresh ripe fruits artificially interested by immature stages of Ceratitis capitata to determine the sterilizing and lethal doses. The sensorial and chemical analyses did not show any significant differences between the control and irradiated samples. Differences on loss of weight of oranges show that 500 and 1000 Gy doses were responsible for increasing the loss of water content. (author)

  9. A comparison study of polymer/cobalt ferrite nano-composites synthesized by mechanical alloying route

    Directory of Open Access Journals (Sweden)

    Sedigheh Rashidi

    2015-12-01

    Full Text Available In this research, the effect of different biopolymers such as polyethylene glycol (PEG and polyvinylalcohol (PVA on synthesis and characterization of polymer/cobalt ferrite (CF nano-composites bymechanical alloying method has been systematically investigated. The structural, morphological andmagnetic properties changes during mechanical milling were investigated by X-ray diffraction (XRD,Fourier transform infrared spectroscopy (FTIR, transmission electron microscopy (TEM, fieldemission scanning electron microscopy (FESEM, and vibrating sample magnetometer techniques(VSM, respectively. The polymeric cobalt ferrite nano-composites were obtained by employing atwo-step procedure: the cobalt ferrite of 20 nm mean particle size was first synthesized by mechanicalalloying route and then was embedded in PEG or PVA biopolymer matrix by milling process. Theresults revealed that PEG melted due to the local temperature raise during milling. Despite thisphenomenon, cobalt ferrite nano-particles were entirely embedded in PEG matrix. It seems, PAV is anappropriate candidate for producing nano-composite samples due to its high melting point. InPVA/CF nano-composites, the mean crystallite size and milling induced strain decreased to 13 nm and0.48, respectively. Moreover, milling process resulted in well distribution of CF in PVA matrix eventhough the mean particle size of cobalt ferrite has not been significantly affecetd. FTIR resultconfirmed the attachment of PVA to the surface of nano-particles. Magnetic properties evaluationshowed that saturation magnetization and coercivity values decreased in nano-composite samplecomparing the pure cobalt ferrite.

  10. Study of complex formation of cobalt (II) and cobalt (III) in acrylamide aqueous solutions and in the phase of acrylamide hydrogel

    International Nuclear Information System (INIS)

    Ismailova, M.M.; Egorova, L.A.; Khamidov, B.O.

    1993-01-01

    Present article is devoted to study of complex formation of cobalt (II) and cobalt (III) in acrylamide aqueous solutions and in the phase of acrylamide hydrogel. The condition of cobalt in various rate of oxidation in acrylamide aqueous solutions was studied. The concentration conditions of stability of system Co(II)-Co(III) were defined. The composition of coordination compounds of cobalt (II) and cobalt (III) in acrylamide aqueous solutions and in the phase of acrylamide hydrogel was determined.

  11. Search for high energy cosmic neutrino point sources with ANTARES

    International Nuclear Information System (INIS)

    Halladjian, G.

    2010-01-01

    The aim of this thesis is the search for high energy cosmic neutrinos emitted by point sources with the ANTARES neutrino telescope. The detection of high energy cosmic neutrinos can bring answers to important questions such as the origin of cosmic rays and the γ-rays emission processes. In the first part of the thesis, the neutrino flux emitted by galactic and extragalactic sources and the number of events which can be detected by ANTARES are estimated. This study uses the measured γ-ray spectra of known sources taking into account the γ-ray absorption by the extragalactic background light. In the second part of the thesis, the absolute pointing of the ANTARES telescope is evaluated. Being located at a depth of 2475 m in sea water, the orientation of the detector is determined by an acoustic positioning system which relies on low and high frequency acoustic waves measurements between the sea surface and the bottom. The third part of the thesis is a search for neutrino point sources in the ANTARES data. The search algorithm is based on a likelihood ratio maximization method. It is used in two search strategies; 'the candidate sources list strategy' and 'the all sky search strategy'. Analysing 2007+2008 data, no discovery is made and the world's best upper limits on neutrino fluxes from various sources in the Southern sky are established. (author)

  12. Nomogram for Determining Shield Thickness for Point and Line Sources of Gamma Rays

    Energy Technology Data Exchange (ETDEWEB)

    Joenemalm, C; Malen, K

    1966-10-15

    A set of nomograms is given for the determination of the required shield thickness against gamma radiation. The sources handled are point and infinite line sources with shields of Pb, Fe, magnetite concrete (p = 3.6), ordinary concrete (p = 2.3) or water. The gamma energy range covered is 0.5 - 10 MeV. The nomograms are directly applicable for source and dose points on the surfaces of the shield. They can easily be extended to source and dose points in other positions by applying a geometrical correction. Also included are data for calculation of the source strength for the most common materials and for fission product sources.

  13. Nomogram for Determining Shield Thickness for Point and Line Sources of Gamma Rays

    International Nuclear Information System (INIS)

    Joenemalm, C.; Malen, K

    1966-10-01

    A set of nomograms is given for the determination of the required shield thickness against gamma radiation. The sources handled are point and infinite line sources with shields of Pb, Fe, magnetite concrete (p = 3.6), ordinary concrete (p = 2.3) or water. The gamma energy range covered is 0.5 - 10 MeV. The nomograms are directly applicable for source and dose points on the surfaces of the shield. They can easily be extended to source and dose points in other positions by applying a geometrical correction. Also included are data for calculation of the source strength for the most common materials and for fission product sources

  14. Recovery of lithium and cobalt from waste lithium ion batteries of mobile phone

    Energy Technology Data Exchange (ETDEWEB)

    Jha, Manis Kumar, E-mail: mkjha@nmlindia.org; Kumari, Anjan; Jha, Amrita Kumari; Kumar, Vinay; Hait, Jhumki; Pandey, Banshi Dhar

    2013-09-15

    Graphical abstract: Recovery of valuable metals from scrap batteries of mobile phone. - Highlights: • Recovery of Co and Li from spent LIBs was performed by hydrometallurgical route. • Under the optimum condition, 99.1% of lithium and 70.0% of cobalt were leached. • The mechanism of the dissolution of lithium and cobalt was studied. • Activation energy for lithium and cobalt were found to be 32.4 kJ/mol and 59.81 kJ/mol, respectively. • After metal recovery, residue was washed before disposal to the environment. - Abstract: In view of the stringent environmental regulations, availability of limited natural resources and ever increasing need of alternative energy critical elements, an environmental eco-friendly leaching process is reported for the recovery of lithium and cobalt from the cathode active materials of spent lithium-ion batteries of mobile phones. The experiments were carried out to optimize the process parameters for the recovery of lithium and cobalt by varying the concentration of leachant, pulp density, reductant volume and temperature. Leaching with 2 M sulfuric acid with the addition of 5% H{sub 2}O{sub 2} (v/v) at a pulp density of 100 g/L and 75 °C resulted in the recovery of 99.1% lithium and 70.0% cobalt in 60 min. H{sub 2}O{sub 2} in sulfuric acid solution acts as an effective reducing agent, which enhance the percentage leaching of metals. Leaching kinetics of lithium in sulfuric acid fitted well to the chemical controlled reaction model i.e. 1 − (1 − X){sup 1/3} = k{sub c}t. Leaching kinetics of cobalt fitted well to the model ‘ash diffusion control dense constant sizes spherical particles’ i.e. 1 − 3(1 − X){sup 2/3} + 2(1 − X) = k{sub c}t. Metals could subsequently be separated selectively from the leach liquor by solvent extraction process to produce their salts by crystallization process from the purified solution.

  15. Calibration of intense 60Co gamma ray sources at the Savannah River Plant

    International Nuclear Information System (INIS)

    Bibler, N.E.

    1976-05-01

    Three different dosimeters were used to calibrate Savannah River Plant 60 Co sources having intensities greater than 10 7 rads/hr. These dosimeters are (a) ceric sulfate dissolved in 0.4M H 2 SO 4 , (b) oxalic acid dissolved in water, and (c) a commercially available nylon film containing a radiochromic dye. Response per unit dose to these dosimeters is independent of radiation intensity at 10 4 to 10 11 rads/hr. The dosimeters were calibrated at 6.0 x 10 5 rads/hr with a 60 Co source whose intensity was determined with the standard Fricke dosimeter. For the sources at 10 7 rads/hr or greater, intensities were calculated from slopes of linear plots of dosimeter response versus irradiation time. Individual dose rates varied from 1.0 x 10 7 to 4.6 x 10 7 rads/hr. Each source was calibrated with at least two different dosimeters. Relative standard deviations varied from 2 to 9 percent. A conservative estimate of the uncertainty in the accuracy of these dosimeters is 10 percent. Of the three dosimeters, the nylon film is easiest to use and is therefore recommended for future calibrations

  16. Point source search techniques in ultra high energy gamma ray astronomy

    International Nuclear Information System (INIS)

    Alexandreas, D.E.; Biller, S.; Dion, G.M.; Lu, X.Q.; Yodh, G.B.; Berley, D.; Goodman, J.A.; Haines, T.J.; Hoffman, C.M.; Horch, E.; Sinnis, C.; Zhang, W.

    1993-01-01

    Searches for point astrophysical sources of ultra high energy (UHE) gamma rays are plagued by large numbers of background events from isotropic cosmic rays. Some of the methods that have been used to estimate the expected number of background events coming from the direction of a possible source are found to contain biases. Search techniques that avoid this problem are described. There is also a discussion of how to optimize the sensitivity of a search to emission from a point source. (orig.)

  17. Phosphorus introduction mechanism in electrodeposited cobalt films

    International Nuclear Information System (INIS)

    Kravtchenko, Jean-Francois

    1973-01-01

    The cathodic reduction of hypophosphite, phosphite and phosphate ions was studied using chrono-potentiometry and voltammetry. Then cobalt was deposited at constant current from a bath containing one of these three compounds. The current, while giving an electrodeposition of cobalt, also enhances at the same time a chemical deposition of cobalt. It is shown that high coercive forces in cobalt films are much more related to this chemical deposition than to the simple fact that the films contain some phosphorus. (author) [fr

  18. Seed germination of peanuts irradiated with cobalt (60CO)

    International Nuclear Information System (INIS)

    Alves, Niedja Marrize C.; Almeida, Francisco de Assis C.; Gomes, Josivanda P.; Pessoa, Elvira B.; Leal, Artur S. Cavalcanti

    2010-01-01

    This work was realized to evaluate the effect of gamma irradiation ( 60 Co) at doses 0, 0.50, 1.00, 1.50, 2.00, 2.50, 3.00 and 4.00 kGy, on germination of seeds of peanut, cultivar BR1. Irradiation Department of Nuclear, UFPE, where he received after the irradiation, they were stored in packing of PET and polyethylene braided with a time of 90 days. Through the results, obtained monthly, concluded that the dose of 0.5 kGy was effective in the germination of seeds of peanut, not affecting its power of germination and overcoming the witness within 30 to 60 days. (author)

  19. Skyshine spectra of gamma rays

    International Nuclear Information System (INIS)

    Swarup, Janardan

    1980-01-01

    A study of the spectra of gamma photons back-scattered in vertical direction by infinite air above ground (skyshine) is presented. The source for these measurements is a 650 Ci Cobalt-60 point-source and the skyshine spectra are reported for distances from 150 m to 325 m from the source, measured with a 5 cm x 5 cm NaI(Tl) detector collimated with collimators of 12 mm and 20 mm diameter and 5 cm length. These continuous spectra are unfolded with Gold's iterative technique. The photon-spectra so obtained have a distinct line at 72 keV due to multiply-scattered photons. This is an energy where photoelectric and Compton cross-sections for multiply-scattered photons balance each other. The intensity of the line(I) decreases exponentially with distance (d) from the source obeying a relation of the type I = Isub(o)esup(-μd) where μ is called as ''Multiply-Scatter Coefficient'', a constant of the medium which is air in these measurements. This relationship is explained in terms of a halo around the source comprising of multiply-scattered gamma photons, Isub(0) being the intensity of these scattered photons at the location of cobalt-source. A fraction called as ''Back-scattered Fraction'', the ratio of Isub(0) to the number of original photons from the cobalt-source entering the infinite air, is also calculated. It is shown that with a properly calibrated detector system, this fraction can be used to determine the strength of a large gamma source, viz. a nuclear explosion in air, and for mineral prospecting. These conclusions are general and can be applied to any other infinite medium. Some forward-scatter (transmission) spectra of cobalt-60 source through 10 cm of Pb and 2.5 cm of Al are also reported. (auth.)

  20. CARDIOPROTECTIVE EFFECT OF NATIVE ANTIHYPOXANTS IN EXPERIMENTAL COBALT CARDIOMYOPATHY

    Directory of Open Access Journals (Sweden)

    I. V. Zadnipryany

    2016-01-01

    Full Text Available The aim of research – the study of cardioprotective properties of antioxidants in terms of histotoxic hypoxia under experimental conditions.Materials and methods. The study was conducted on 20 adult male Wistar rats divided into 3 experimental groups, which for 7 days were intraperitoneally injected aqueous CoCl2 solution at a dose of 60 mg/kg. Rats of the first experimental group (n = 6 had no administered drug correction, a the second group of animals (n = 7 after the cobalt chloride daily injections was administered intragastrically Enoant Premium aqueous solution at a dose of 2.5 ml / kg, along with 0.05 ml of water, the rats the third test group (n = 7 after the administration of cobalt chloride were exposed to cytoflavin correction concentrate and grape polyphenols administered simultaneously. Studies of myocardium were conducted using light and electron microscopy.Results of the research. The result of the cobalt toxic effect on the heart of animals in experiments lead to the development of cardiomyopathy, which required timely cardioprotection. Morphological changes in the second group of rats, despite a slight improvement compared with the group without correction,were characterized, above all, by uneven from mild to severe edema of the myocardium. Structure of myocardium observed in the third group of male rats after cobalt intoxication, generally reflected a tendency to minimization of the extent of the damage, which was manifested in the form of normalization of cell structures and muscle fibers.Conclusion. The administration of succinic acid derivatives combined with the grape polyphenols demonstrated vivid cytoprotective properties evidenced by mostly preserved myocardium structure in rats exposed to histotoxic hypoxia in comparison to only administration of plant polyphenols group. 

  1. A XANES study of cobalt speciation state in blue-and-white glazes from 16th to 17th century Chinese porcelains

    Energy Technology Data Exchange (ETDEWEB)

    Figueiredo, M.O., E-mail: ondina.figueiredo@lneg.pt [CENIMAT/I3N, Faculty Sciences and Technology, New University of Lisbon, Campus da Caparica, 2829-516 Caparica (Portugal); National Laboratory of Energy and Geology (LNEG), Apartado 7586, 2721-866 Alfragide (Portugal); Silva, T.P. [National Laboratory of Energy and Geology (LNEG), Apartado 7586, 2721-866 Alfragide (Portugal); CENIMAT/I3N, Faculty Sciences and Technology, New University of Lisbon, Campus da Caparica, 2829-516 Caparica (Portugal); Veiga, J.P. [CENIMAT/I3N, Faculty Sciences and Technology, New University of Lisbon, Campus da Caparica, 2829-516 Caparica (Portugal)

    2012-04-15

    Highlights: Black-Right-Pointing-Pointer Speciation of cobalt in ancient Chinese porcelain glazes studied by X-ray absorption near-edge spectroscopy. Black-Right-Pointing-Pointer Blue pigmenting role of tetrahedral Co{sup 2+} ions. Black-Right-Pointing-Pointer Uncertainties in deducing a formal valence state for cobalt ions from the edge energy. - Abstract: The composition of cobalt blue pigments used in ancient blue-and-white Chinese glazes is known to have changed between the 14th and the 17th century and ratios of some main chemical components plus trace elements are relevant guide-lines to establish the porcelain manufacture period. Once archaeological findings of Chinese porcelains can contribute to set up dating processes, a study of blue-and-white porcelain shards recovered during recent excavations in Lisbon Old-City was carried out by non-destructive laboratory X-ray fluorescence spectrometry for chemical characterization, combined with X-ray absorption spectroscopy (XAS) using synchrotron radiation to ascertain the formal valence and coordination of pigmenting cobalt ions. Following a preliminary extended X-ray absorption fine-structure study that revealed a coordination of divalent cobalt ions slightly above four, a detailed analysis of the near-edge region of Co 1s X-ray absorption spectra (XANES) was carried out on the blue-and-white glazes from those archaeological Chinese porcelain fragments. Pre-edge features and edge details are discussed in comparison with XANES spectra obtained from model compounds with well known crystal structure - Co{sub 3}O{sub 4}, CoAl{sub 2}O{sub 4} and Co{sub 2}SiO{sub 4}, plus a cobalt-based blue pigment (cerulean). Present chemical data validate the manufacture period of studied Chinese porcelains advanced by Art Historians on the single basis of stylistic features (late 16th and medium 17th century). Spectroscopic results confirm a coordination environment of pigmenting Co{sup 2+} ions close to tetrahedral and

  2. The role of livestock-poached pasture as a sediment source

    Science.gov (United States)

    Greenwood, Philip; Walling, Desmond; Quine, Timothy

    2015-04-01

    Historically, the occurrence of sediment-laden runoff has almost exclusively been associated with cultivated hillslopes and particularly with arable land. This association was commonly accompanied by the presumption that, in comparison with cultivated slopes, erosion from intensively-managed lowland pasture was relatively low. Recent developments in sediment source tracing and fingerprinting techniques have, however, challenged these assumptions by demonstrating that soil loss from grasslands may be greater than previously assumed. In attempting to identify potential source areas within grassland environments, attention has frequently focused on areas of livestock poaching where herd animals tend to congregate. However, the role of poached grassland as a sediment-source remains uncertain. Reasons include the difficulties associated with accurately documenting the movement or redistribution of small quantities of fine sediment over relevant spatial and temporal scales. Motivated by an urgent need for such information, this communication presents preliminary results from a tracing study aimed at measuring sediment redistribution within areas of poached pasture over short (i.e. event-based) timescales using the artificial radionuclides, caesium-134 (134Cs) and cobalt-60 (60Co). The approach involved labelling six small areas (0.2 * 0.2 m) of poached soil, each with a contrasting gradient, with either 134Cs or 60Co, and then measuring changes in the radiometric inventory at predetermined points before and after periods of rainfall. Each labelled area of poached pasture was measured on three separate occasions over a 65 day period. At the end of the monitoring phase, the mean net soil redistribution depth (mm) was negative for all plots, with values ranging from -6.8 mm to -15.2 mm. This is interpreted as evidence of the removal, or erosion, of surface material. The findings indicate that areas of livestock-poached pasture can act as significant sediment sources. These

  3. JT-60SA vacuum vessel manufacturing and assembly

    Energy Technology Data Exchange (ETDEWEB)

    Masaki, Kei, E-mail: masaki.kei@jaea.go.jp [Japan Atomic Energy Agency, Naka, Ibaraki-ken 311-0193 (Japan); Shibama, Yusuke K.; Sakurai, Shinji; Shibanuma, Kiyoshi; Sakasai, Akira [Japan Atomic Energy Agency, Naka, Ibaraki-ken 311-0193 (Japan)

    2012-08-15

    Highlights: Black-Right-Pointing-Pointer The design of the JT-60SA vacuum vessel body was completed with the demonstration of manufacturing procedure by the mock-up fabrication of the 20 Degree-Sign upper half of VV. Black-Right-Pointing-Pointer The actual VV manufacturing has started since November 2009. Black-Right-Pointing-Pointer The first product of the VV 40 Degree-Sign sector was completed in May 2011. Black-Right-Pointing-Pointer A basic VV assembly scenario and procedure were studied to complete the 360 Degree-Sign VV including positioning method and joint welding. - Abstract: The JT-60SA vacuum vessel (VV) has a D-shaped poloidal cross section and a toroidal configuration with 10 Degree-Sign segmented facets. A double wall structure is adopted to ensure high rigidity at operational load and high toroidal one-turn resistance. The material is 316L stainless steel with low cobalt content (<0.05%). The design temperatures of the VV at plasma operation and baking are 50 Degree-Sign C and 200 Degree-Sign C, respectively. In the double wall, boric-acid water is circulated at plasma operation to reduce the nuclear heating of the superconducting magnets. For baking, nitrogen gas is circulated in the double wall after draining of the boric-acid water. The manufacturing of the VV started in November 2009 after a fundamental welding R and D and a trial manufacturing of 20 Degree-Sign upper half mock-up. The manufacturing of the first VV 40 Degree-Sign sector was completed in May 2011. A basic concept and required jigs of the VV assembly were studied. This paper describes the design and manufacturing of the vacuum vessel. A plan of VV assembly in torus hall is also presented.

  4. Open-Source Automated Mapping Four-Point Probe

    Directory of Open Access Journals (Sweden)

    Handy Chandra

    2017-01-01

    Full Text Available Scientists have begun using self-replicating rapid prototyper (RepRap 3-D printers to manufacture open source digital designs of scientific equipment. This approach is refined here to develop a novel instrument capable of performing automated large-area four-point probe measurements. The designs for conversion of a RepRap 3-D printer to a 2-D open source four-point probe (OS4PP measurement device are detailed for the mechanical and electrical systems. Free and open source software and firmware are developed to operate the tool. The OS4PP was validated against a wide range of discrete resistors and indium tin oxide (ITO samples of different thicknesses both pre- and post-annealing. The OS4PP was then compared to two commercial proprietary systems. Results of resistors from 10 to 1 MΩ show errors of less than 1% for the OS4PP. The 3-D mapping of sheet resistance of ITO samples successfully demonstrated the automated capability to measure non-uniformities in large-area samples. The results indicate that all measured values are within the same order of magnitude when compared to two proprietary measurement systems. In conclusion, the OS4PP system, which costs less than 70% of manual proprietary systems, is comparable electrically while offering automated 100 micron positional accuracy for measuring sheet resistance over larger areas.

  5. Open-Source Automated Mapping Four-Point Probe.

    Science.gov (United States)

    Chandra, Handy; Allen, Spencer W; Oberloier, Shane W; Bihari, Nupur; Gwamuri, Jephias; Pearce, Joshua M

    2017-01-26

    Scientists have begun using self-replicating rapid prototyper (RepRap) 3-D printers to manufacture open source digital designs of scientific equipment. This approach is refined here to develop a novel instrument capable of performing automated large-area four-point probe measurements. The designs for conversion of a RepRap 3-D printer to a 2-D open source four-point probe (OS4PP) measurement device are detailed for the mechanical and electrical systems. Free and open source software and firmware are developed to operate the tool. The OS4PP was validated against a wide range of discrete resistors and indium tin oxide (ITO) samples of different thicknesses both pre- and post-annealing. The OS4PP was then compared to two commercial proprietary systems. Results of resistors from 10 to 1 MΩ show errors of less than 1% for the OS4PP. The 3-D mapping of sheet resistance of ITO samples successfully demonstrated the automated capability to measure non-uniformities in large-area samples. The results indicate that all measured values are within the same order of magnitude when compared to two proprietary measurement systems. In conclusion, the OS4PP system, which costs less than 70% of manual proprietary systems, is comparable electrically while offering automated 100 micron positional accuracy for measuring sheet resistance over larger areas.

  6. Indias Capabilities in Food Irradiation

    International Nuclear Information System (INIS)

    Ramesh, V.

    2005-09-01

    Full-text: India recently celebrated 50 years of nuclear application and criticality. Radiation processing Technology has been investigated and demonstrated for nearly four decades by food scientists and technologists at Bhabha Atomic Research Center, (BARC), India. It is quite essential to clarify unambiguously that under no circumstances can radiation processing using cobalt-60 radiation induce any radioactivity and naturally, leave residual radioactivity in the material being processed. To this extent, the word IRRADIATION has been replaced by the word Radiation Processing. The Indian Navy had recently approved the use of radiation processing for preserving high value food products and to optimize the procurement cost and maximize the product availability. The Board of Radiation and Isotope Technology (BRIT), India has achieved significant milestones in encouraging private entrepreneurs to set up Radiation Processing plants for food preservation and safety as well as for non-food products and medical equipment sterilization. Today there are about 25 private radiation processing plants getting ready to meet the demand and many more are following the trend. With the growing demand for Cobalt-60 source, India has exported the technology and the source to many neighboring countries and is prepared to meet the demand and support the requirements of the Cobalt-60 source in Thailand. Innovative Food Technologies Co. Ltd provide consultancy and turnkey projects to set up Radiation processing Plants, Supply of Cobalt-60 source, Refurbishing Cobalt-60 source, provide comprehensive training in Plant safety, maintenance and security in Thailand and ASEAN

  7. Scattering and absorption of particles emitted by a point source in a cluster of point scatterers

    International Nuclear Information System (INIS)

    Liljequist, D.

    2012-01-01

    A theory for the scattering and absorption of particles isotropically emitted by a point source in a cluster of point scatterers is described and related to the theory for the scattering of an incident particle beam. The quantum mechanical probability of escape from the cluster in different directions is calculated, as well as the spatial distribution of absorption events within the cluster. A source strength renormalization procedure is required. The average quantum scattering in clusters with randomly shifting scatterer positions is compared to trajectory simulation with the aim of studying the validity of the trajectory method. Differences between the results of the quantum and trajectory methods are found primarily for wavelengths larger than the average distance between nearest neighbour scatterers. The average quantum results include, for example, a local minimum in the number of absorption events at the location of the point source and interference patterns in the angle-dependent escape probability as well as in the distribution of absorption events. The relative error of the trajectory method is in general, though not generally, of similar magnitude as that obtained for beam scattering.

  8. Analysis of ZPPR experiments supporting production of 60Co in FFTF

    International Nuclear Information System (INIS)

    Wootan, D.W.; Carter, L.L.; Rawlins, J.A.; Schaefer, R.W.; Maddison, D.W.

    1987-01-01

    An effort to expand the irradiation mission of the Fast Flux Test Facility (FFTF) beyond testing fuels and materials for the liquid-metal reactor (LMR) program included a study of the feasibility of producing commercial quantities of 60 Co. The 60 Co would be produced by neutron capture in assemblies containing an array of natural cobalt pins and hydrogen-bearing moderator pins located at the periphery of the FFTF core. Adding hydrogenous material to the assemblies enhances 60 Co production by slowing neutrons into energy ranges where the 59 Co capture cross section is higher. Some of the moderated neutrons leak from the moderated region to adjacent fuel regions, increasing local fission rates. In order to validate calculated fission rates and establish calculational biases and uncertainties, experiments were conducted in the zero-power plutonium reactor (ZPPR) to measure fission rates in fuel regions adjacent to a mock-up of a cobalt production assembly. The ZPPR experiment and analyses provided the technical basis for irradiating hydride-moderated assemblies in FFTF and a cobalt production cycle of FFTF with generally good agreement between measured and predicted reactivity worth and outlet temperatures in adjacent fuel assemblies. This experiment provides a benchmark configuration of a hydrogenous assembly in a fast reactor, with emphasis on the effect of the hydrogen on adjacent fuel. It is anticipated there will be other applications of hydride moderation in the development of future isotope production missions in FFTF

  9. Use of inorganic and organic compounds as decontaminates for cobalt T-60 and cesium-134 by clover plant grown on Inshas Sandy soil

    International Nuclear Information System (INIS)

    Abdel-Sabour, M.F.; El-naggr, H.A.; Soliman, S.M.

    1994-01-01

    Out door lysimeter experiment was carried out to elucidate the effect of four inorganic and three organic salts on 60 Co and 134 Cs uptake and dry matter yield of three cuts of clover in the soil Inshas A new concept was proposed for assessing the difference in capacity of soil to supply radionuclides (i.e. 60 Co and 134 Cs) to plants as affected by applied inorganic or organic compounds. The relation of plant tissues (P c ) Co/IR Cs content with increasing time can be expressed as log (Pc) = A + B log time (T), where A and B the regression. When the same plant species is grown on the same soil differ only in the applied compound (e.g. Fe-EDDHA, Fe-DTPA, Fe-O A C, Fe(Coo)z, A1(OH)3, Ca(H2 P O 4 )2 and Fe 2 O 3 ) the equation will change to, log (P'c) = A + B' log (T) (I). Based on both equations, the relationship between (Pc) becomes; log (P'c) = [(A'B')/(A B + A B ) [ +[1/A'B + A B ) [ log (Pc) (II). The intercept (C) and slope (S) in Eq. (II) were determined among 7 treatments (for either 60 Co or 134 Cs). Then the difference of either Co or Cs accumulation with time between control and any other treatment was evaluated according to (C) and (S) values. The data also that Fe-DTPA is preferred for 60 Co as enhancing compound for plant uptake (for decontamination use); compared with other applied salts; on the other hand, any tested salts did not significantly effect 134 Cs taken by clover. Also, it was found that more than 70% of total cobalt uptake was accumulated in the roots which indicate that Co is less mobile in plants than Cs. 3 figs., 4 tabs

  10. Experimental evidence for cobalt(III)-carbene radicals: key intermediates in cobalt(II)-based metalloradical cyclopropanation

    NARCIS (Netherlands)

    Lu, H.; Dzik, W.I.; Xu, X.; Wojtas, L.; de Bruin, B.; Zhang, X.P.

    2011-01-01

    New and conclusive evidence has been obtained for the existence of cobalt(III)-carbene radicals that have been previously proposed as the key intermediates in the underlying mechanism of metalloradical cyclopropanation by cobalt(II) complexes of porphyrins. In the absence of olefin substrates,

  11. Distribution measurement of 60Co target radioactive specific activity

    International Nuclear Information System (INIS)

    Li Xingyan; Chen Zigen; Ren Min

    1994-01-01

    Radioactive specific activity distribution of cobalt 60 target by irradiation in HFETR is a key parameter. With the collimate principle, the under water measurement device and conversion coefficient which is get by experiments, and the radioactive specific activity distribution is obtained. The uncertainty of measurement is less than 10%

  12. Palladium-cobalt particles as oxygen-reduction electrocatalysts

    Science.gov (United States)

    Adzic, Radoslav [East Setauket, NY; Huang, Tao [Manorville, NY

    2009-12-15

    The present invention relates to palladium-cobalt particles useful as oxygen-reducing electrocatalysts. The invention also relates to oxygen-reducing cathodes and fuel cells containing these palladium-cobalt particles. The invention additionally relates to methods for the production of electrical energy by using the palladium-cobalt particles of the invention.

  13. Removal of Cobalt Ions by Precipitate Foam Flotation

    Energy Technology Data Exchange (ETDEWEB)

    Jung, In Ha; Lee, Jung Won [Korea Atomic Energy Research Institute, Taejon (Korea)

    1998-09-30

    Simulated waste liquid containing 50 ppm cobalt ion was tested by precipitate flotation using a sodium lauryl sulfate as a collector. The effects of initial cobalt ion concentration, pH, surfactant concentration, flotation time, gas flow rate and foreign ions on removal efficiency of cobalt ion were studied. Pretreatment of the waste liquid with 35% H{sub 2}O{sub 2} prior to precipitate flotation made shift of optimal flotation pH from the strong alkalinity to weak alkaline range and made a favorable flotation of cobalt ion in wide range of pH. For the result of this experiment, 99.8% removal efficiency was obtained on the conditions of initial cobalt ion concentration 50 ppm, pH 9.5, gas flow rate 70 ml/min, flotation time 30 min. The simulate ion was formed to be the most harmful ion against removal of cobalt by precipitate flotation of the species which were tested. The presence of 0.1 M of SO{sub 4}{sup 2-} ion decreased removal efficiency of cobalt to 90% while the cobalt were almost entirely removed in the absence of sulfate ion. (author). 11 refs., 8 figs.

  14. Metabolite profiling uncovers plasmid-induced cobalt limitation under methylotrophic growth conditions.

    Directory of Open Access Journals (Sweden)

    Patrick Kiefer

    2009-11-01

    Full Text Available The introduction and maintenance of plasmids in cells is often associated with a reduction of growth rate. The reason for this growth reduction is unclear in many cases.We observed a surprisingly large reduction in growth rate of about 50% of Methylobacterium extorquens AM1 during methylotrophic growth in the presence of a plasmid, pCM80 expressing the tetA gene, relative to the wild-type. A less pronounced growth delay during growth under non-methylotrophic growth conditions was observed; this suggested an inhibition of one-carbon metabolism rather than a general growth inhibition or metabolic burden. Metabolome analyses revealed an increase in pool sizes of ethylmalonyl-CoA and methylmalonyl-CoA of more than 6- and 35-fold, respectively, relative to wild type, suggesting a strongly reduced conversion of these central intermediates, which are essential for glyoxylate regeneration in this model methylotroph. Similar results were found for M. extorquens AM1 pCM160 which confers kanamycin resistance. These intermediates of the ethylmalonyl-CoA pathway have in common their conversion by coenzyme B(12-dependent mutases, which have cobalt as a central ligand. The one-carbon metabolism-related growth delay was restored by providing higher cobalt concentrations, by heterologous expression of isocitrate lyase as an alternative path for glyoxylate regeneration, or by identification and overproduction of proteins involved in cobalt import.This study demonstrates that the introduction of the plasmids leads to an apparent inhibition of the cobalt-dependent enzymes of the ethylmalonyl-CoA pathway. Possible explanations are presented and point to a limited cobalt concentration in the cell as a consequence of the antibiotic stress.

  15. Resolution of point sources of light as analyzed by quantum detection theory.

    Science.gov (United States)

    Helstrom, C. W.

    1973-01-01

    The resolvability of point sources of incoherent thermal light is analyzed by quantum detection theory in terms of two hypothesis-testing problems. In the first, the observer must decide whether there are two sources of equal radiant power at given locations, or whether there is only one source of twice the power located midway between them. In the second problem, either one, but not both, of two point sources is radiating, and the observer must decide which it is. The decisions are based on optimum processing of the electromagnetic field at the aperture of an optical instrument. In both problems the density operators of the field under the two hypotheses do not commute. The error probabilities, determined as functions of the separation of the points and the mean number of received photons, characterize the ultimate resolvability of the sources.

  16. Absolute calibration of the neutron yield measurement on JT-60 Upgrade

    International Nuclear Information System (INIS)

    Nishitani, Takeo; Takeuchi, Hiroshi; Barnes, C.W.

    1991-10-01

    Absolutely calibrated measurements of the neutron yield are important for the evaluation of the plasma performance such as the fusion gain Q in DD operating tokamaks. Total neutron yield is measured with 235 U and 238 U fission chambers and 3 He proportional counters in JT-60 Upgrade. The in situ calibration was performed by moving the 252 Cf neutron source toroidally through the JT-60 vacuum vessel. Detection efficiencies of three 235 U and two 3 He detectors were measured for 92 locations of the neutron point source in toroidal scans at two different major radii. The total detection efficiency for the torus neutron source was obtained by averaging the point efficiencies over the whole toroidal angle. The uncertainty of the resulting absolute plasma neutron source calibration is estimated to be ± 10%. (author)

  17. Cobalt: for strength and color

    Science.gov (United States)

    Boland, Maeve A.; Kropschot, S.J.

    2011-01-01

    Cobalt is a shiny, gray, brittle metal that is best known for creating an intense blue color in glass and paints. It is frequently used in the manufacture of rechargeable batteries and to create alloys that maintain their strength at high temperatures. It is also one of the essential trace elements (or "micronutrients") that humans and many other living creatures require for good health. Cobalt is an important component in many aerospace, defense, and medical applications and is a key element in many clean energy technologies. The name cobalt comes from the German word kobold, meaning goblin. It was given this name by medieval miners who believed that troublesome goblins replaced the valuable metals in their ore with a substance that emitted poisonous fumes when smelted. The Swedish chemist Georg Brandt isolated metallic cobalt-the first new metal to be discovered since ancient times-in about 1735 and identified some of its valuable properties.

  18. Mapping correlation of a simulated dark matter source and a point source in the gamma-ray sky - Oral Presentation

    Energy Technology Data Exchange (ETDEWEB)

    Gibson, Alexander [SLAC National Accelerator Lab., Menlo Park, CA (United States)

    2015-08-23

    In my research, I analyzed how two gamma-ray source models interact with one another when optimizing to fit data. This is important because it becomes hard to distinguish between the two point sources when they are close together or looking at low energy photons. The reason for the first is obvious, the reason why they become harder to distinguish at lower photon energies is the resolving power of the Fermi Gamma-Ray Space Telescope gets worse at lower energies. When the two point sources are highly correlated (hard to distinguish between), we need to change our method of statistical analysis. What I did was show that highly correlated sources have larger uncertainties associated with them, caused by an optimizer not knowing which point source’s parameters to optimize. I also mapped out where their is high correlation for 2 different theoretical mass dark matter point sources so that people analyzing them in the future knew where they had to use more sophisticated statistical analysis.

  19. Experimental determination of gamma radiation effect from cobalt 60 on the viscosity of SSBR-B polymer

    International Nuclear Information System (INIS)

    Santos, L.G. dos; Silva Filho, E.

    1989-01-01

    Samples of the polymer known as SSBR-B (Solution Styrenne Butadiene Rubber-Blockade) were irradiated with gamma rays from a 60 Co source. Viscosity analysis performed by using the method of Ostwald Showed that the viscosity remains about constant for doses in the range of zero to 11560 Gray (Gy). For doses greater than 11560 Gy the viscosity increases. This result characterizes an irradiation induced hardening of the polymer. (author) [pt

  20. Design of inspection equipment vehicle of mobile cobalt-60 container scanner

    International Nuclear Information System (INIS)

    Zhang Yanmin; An Jigang; Zhou Liye; Liu Yisi; Wu Zhifang; Xiang Xincheng; Huang Songling

    2000-01-01

    The author introduced the design principle of Inspection Equipment Vehicle of TCM-SCAN Mobile 60 Co container inspection system. Three schemes had been compared. The scheme of scan gate in form of pucker-able rails standing on the vehicle was determined. Prototype was prepared in September 1999. Mobile 60 Co container inspection system had the same inspection performance of fixed 60 Co container inspection system

  1. Effects of cobalt in nickel-base superalloys

    Science.gov (United States)

    Tien, J. K.; Jarrett, R. N.

    1983-01-01

    The role of cobalt in a representative wrought nickel-base superalloy was determined. The results show cobalt affecting the solubility of elements in the gamma matrix, resulting in enhanced gamma' volume fraction, in the stabilization of MC-type carbides, and in the stabilization of sigma phase. In the particular alloy studied, these microstructural and microchemistry changes are insufficient in extent to impact on tensile strength, yield strength, and in the ductilities. Depending on the heat treatment, creep and stress rupture resistance can be cobalt sensitive. In the coarse grain, fully solutioned and aged condition, all of the alloy's 17% cobalt can be replaced by nickel without deleteriously affecting this resistance. In the fine grain, partially solutioned and aged condition, this resistance is deleteriously affected only when one-half or more of the initial cobalt content is removed. The structure and property results are discussed with respect to existing theories and with respect to other recent and earlier findings on the impact of cobalt, if any, on the performance of nickel-base superalloys.

  2. 40 CFR 407.60 - Applicability; description of the canned and preserved fruits subcategory.

    Science.gov (United States)

    2010-07-01

    ... canned and preserved fruits subcategory. 407.60 Section 407.60 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS CANNED AND PRESERVED FRUITS AND VEGETABLES PROCESSING POINT SOURCE CATEGORY Canned and Preserved Fruits Subcategory § 407.60 Applicability; description...

  3. Cobalt and vitamin B12 in diets for commercial laying hens on the second cycle of production

    Directory of Open Access Journals (Sweden)

    RK Kato

    2003-04-01

    Full Text Available The supplementation of cobalt and vitamin B12 in diets for commercial laying hens on the second production cycle was studied. Four hundred and eighty light commercial laying hens, Lohmann LSL, were used at initial phase of forced molting laying period. The trial was conducted in a randomized design. The plots were the treatments which were constituted by combination of five cobalt levels (0.00; 0.30; 0.60; 0.90 and 1.20ppm and two vitamin B12 levels (without and with 10µ/kg, and the split-plots were four periods (21, 42, 63 and 84 days during the second period of production, with 4 repetitions and 12 hens per experimental unit. Food and water were provided ad libitum and eggs were collected twice daily. Performance and egg quality parameters were evaluated. At the end of experimental period, two layers from each treatment were slaughtered, and liver and blood samples were taken for analysis. Performance and egg quality were not different (p>0.05 among cobalt supplementation levels, although egg damage data were different (p<0.05. Supplementation with vitamin B12 decreased egg weight. No influence of cobalt or vitamin B12 supplementation was seen on the concentration of cobalt in the liver and yolk as well as on blood analysis (hematrocrit, hemoglobin, erythrocytes, and leukocytes. The results revealed that vitamin B12 supplementation was important for commercial laying hens on the second cycle of production, but not cobalt supplementation.

  4. Localization of Point Sources for Poisson Equation using State Observers

    KAUST Repository

    Majeed, Muhammad Usman

    2016-08-09

    A method based On iterative observer design is presented to solve point source localization problem for Poisson equation with riven boundary data. The procedure involves solution of multiple boundary estimation sub problems using the available Dirichlet and Neumann data from different parts of the boundary. A weighted sum of these solution profiles of sub-problems localizes point sources inside the domain. Method to compute these weights is also provided. Numerical results are presented using finite differences in a rectangular domain. (C) 2016, IFAC (International Federation of Automatic Control) Hosting by Elsevier Ltd. All rights reserved.

  5. Localization of Point Sources for Poisson Equation using State Observers

    KAUST Repository

    Majeed, Muhammad Usman; Laleg-Kirati, Taous-Meriem

    2016-01-01

    A method based On iterative observer design is presented to solve point source localization problem for Poisson equation with riven boundary data. The procedure involves solution of multiple boundary estimation sub problems using the available Dirichlet and Neumann data from different parts of the boundary. A weighted sum of these solution profiles of sub-problems localizes point sources inside the domain. Method to compute these weights is also provided. Numerical results are presented using finite differences in a rectangular domain. (C) 2016, IFAC (International Federation of Automatic Control) Hosting by Elsevier Ltd. All rights reserved.

  6. Protective role of Hippopahe leaves against kidney damage in total body 60Co-gamma-irradiated mice

    International Nuclear Information System (INIS)

    Saini, Manu; Prasad, Jagdish; Bala, Madhu

    2012-01-01

    Hippophae rhamnoides has diverse therapeutic applications in Indian, Chinese and Tibetan medicine. Our earlier studies have shown that pretreatment with Hippophae leaf extract rendered >90% survival in mice population. The objective of this study was to investigate the role of our herbal preparation from Hippophae leaf against radiation induced kidney damage. The study was conducted with Strain 'A' male mice weighing approximately 28 ±2 g. The mice were administered Hippophae leaf extract, 30 minutes prior to 60 cobalt-gamma irradiation. The weight of kidneys and histological changes in kidney tissues at the light microscopic level were examined at 2, 5, 7, 10 and 15 days after treatment. The results showed that no significant change was observed in kidney weight after 60 cobalt-gamma irradiation. The glomerular damage in the form of glomerular sclerosis and percentage of damaged glomeruli; tubular damage in form of tubular dilations; apoptosis, and interstitial hemorrhages in renal cortex was also observed after radiation treatment. The pretreatment with Hippophae leaf extract countered most of the histological alterations induced by radiation. In comparison to radiation alone group, there was a significant decrease (p 60 cobalt gamma radiation induced damage. (author)

  7. Cobalt: A vital element in the aircraft engine industry

    Science.gov (United States)

    Stephens, J. R.

    1981-01-01

    Recent trends in the United States consumption of cobalt indicate that superalloys for aircraft engine manufacture require increasing amounts of this strategic element. Superalloys consume a lion's share of total U.S. cobalt usage which was about 16 million pounds in 1980. In excess of 90 percent of the cobalt used in this country was imported, principally from the African countries of Zaire and Zambia. Early studies on the roles of cobalt as an alloying element in high temperature alloys concentrated on the simple Ni-Cr and Nimonic alloy series. The role of cobalt in current complex nickel base superalloys is not well defined and indeed, the need for the high concentration of cobalt in widely used nickel base superalloys is not firmly established. The current cobalt situation is reviewed as it applies to superalloys and the opportunities for research to reduce the consumption of cobalt in the aircraft engine industry are described.

  8. Cobalt Xanthate Thin Film with Chemical Bath Deposition

    Directory of Open Access Journals (Sweden)

    İ. A. Kariper

    2013-01-01

    Full Text Available Cobalt xanthate thin films (CXTFs were successfully deposited by chemical bath deposition, onto amorphous glass substrates, as well as on p- and n-silicon, indium tin oxide, and poly(methyl methacrylate. The structure of the films was analyzed by far-infrared spectrum (FIR, mid-infrared (MIR spectrum, nuclear magnetic resonance (NMR, and scanning electron microscopy (SEM. These films were investigated from their structural, optical, and electrical properties point of view. Electrical properties were measured using four-point method, whereas optical properties were investigated via UV-VIS spectroscopic technique. Uniform distribution of grains was clearly observed from the photographs taken by scanning electron microscope (SEM. The transmittance was about 70–80% (4 hours, 50°C. The optical band gap of the CXTF was graphically estimated to be 3.99–4.02 eV. The resistivity of the films was calculated as 22.47–75.91 Ω·cm on commercial glass depending on film thickness and 44.90–73.10 Ω ·cm on the other substrates. It has been observed that the relative resistivity changed with film thickness. The MIR and FIR spectra of the films were in agreement with the literature analogues. The expected peaks of cobalt xanthate were observed in NMR analysis on glass. The films were dipped in chloroform as organic solvent and were analyzed by NMR.

  9. Investigation of Chitosan for Decorporation of 60Co in the Rat

    International Nuclear Information System (INIS)

    Levitskaia, Tatiana G.; Creim, Jeffrey A.; Curry, Terry L.; Luders, Teresa; Morris, James E.; Sinkov, Sergey I.; Woodstock, Angela D.; Thrall, Karla D.

    2009-01-01

    Purpose: The reported investigation is a part of our on-going research aimed at identifying effective in vivo non-toxic decorporation agents and developing new therapies to treat internal contamination with radionuclides. The non-toxic nature of chitosan makes it an especially attractive candidate for unsupervised treatment of the general population in case of radiological/nuclear emergency. In this study, chemically unmodified water-soluble chitosan oligosaccharide of low molecular weight was tested for decorporation of cobalt-60 (Co-60) using a rodent model. Methods: Affinity of chitosan oligosaccharide for Co(II) was tested in vitro under conditions of physiological pH range and ionic strength using combined spectrophotometric and potentiometric titration techniques. Fisher F344 rat model was used for in vivo studies. To evaluate effect of chitosan on ingested Co-60, animals received single oral dose of Co-60 chloride (7-13.2 kBq per animal) followed by oral administration of chitosan material (288-366 mg per kg body weight); chitosan dosing was repeated in 24 hours. Chitosan was also tested for removal of internalized Co-60. In this study, Co-60 single intravenous injection (7-8 kBq per animal) was followed by repetitive oral (300 mg per kg body weight) or intravenous (195 mg per kg body weight) administration of the chitosan material once daily for 5 days. Control animal groups received a single dose of Co-60 without chelator treatment. Excreta was collected daily. Tissues were collected postmortem and analyzed for radioactivity by gamma counting technique. Results: In vitro experiments confirmed binding of Co(II) by chitosan oligosaccharide, formation of mixed cobalt-chitosan-hydroxide complex species was proposed, and stability constants was calculated. Control in vivo studies indicated that about 71% of ingested Co-60 was excreted in two days predominantly through the gastrointestinal tract. For intravenously administered Co-60, urinal excretion was

  10. Use of some inorganic and organic compounds as decontaminants for cobalt-60 and caesium-134 by clover plant grown on Inshas sandy soil

    Energy Technology Data Exchange (ETDEWEB)

    Abdel Sabour, M.F.; El-Naggar, H.A.; Soliman, S.M. (Atomic Energy Establishment, Cairo (Egypt). Nuclear Chemistry Dept.)

    1991-01-01

    Outdoor lysimeter experiments were carried out to elucidate the effect of 4 inorganic and 3 organic salts on {sup 60}Co and {sup 134}Cs uptake and dry matter yield of three cuts of clover in the soils of Inshas. A new concept was proposed for assessing the difference in capacity of soil to supply radionuclides to plants as affected by applied inorganic or organic compounds. A relation of plant tissue radionuclide content with time can be expressed in an exponential equation with corresponding regression coefficients. When the same plant species is grown on the same soil differing only in the applied compounds (e.g. Fe-EDDHA, Fe-DTPA, Fe-OAC, Fe(COO){sub 2}, Al(OH){sub 3}, Ca(H{sub 2}PO{sub 4}){sub 2}, Fe{sub 2}O{sub 3}) the derived equation will change. Differences of either Co or Cs accumulation with time between control and any other treatment were evaluated. The data also show that Fe-DTPA is preferred for {sup 60}Co as enhancing compound for plant uptake (for decontamination use), compared with other applied salts, on the other hand, any tested salts did not significantly effect {sup 134}Cs taken by clover. It was also found that more than 70% of the total cobalt uptake was accumulated in the roots which indicate that Co is less mobile in plants than Cs. (orig.).

  11. Use of some inorganic and organic compounds as decontaminants for cobalt-60 and caesium-134 by clover plant grown on Inshas sandy soil

    International Nuclear Information System (INIS)

    Abdel Sabour, M.F.; El-Naggar, H.A.; Soliman, S.M.

    1991-01-01

    Outdoor lysimeter experiments were carried out to elucidate the effect of 4 inorganic and 3 organic salts on 60 Co and 134 Cs uptake and dry matter yield of three cuts of clover in the soils of Inshas. A new concept was proposed for assessing the difference in capacity of soil to supply radionuclides to plants as affected by applied inorganic or organic compounds. A relation of plant tissue radionuclide content with time can be expressed in an exponential equation with corresponding regression coefficients. When the same plant species is grown on the same soil differing only in the applied compounds (e.g. Fe-EDDHA, Fe-DTPA, Fe-OAC, Fe(COO) 2 , Al(OH) 3 , Ca(H 2 PO 4 ) 2 , Fe 2 O 3 ) the derived equation will change. Differences of either Co or Cs accumulation with time between control and any other treatment were evaluated. The data also show that Fe-DTPA is preferred for 60 Co as enhancing compound for plant uptake (for decontamination use), compared with other applied salts, on the other hand, any tested salts did not significantly effect 134 Cs taken by clover. It was also found that more than 70% of the total cobalt uptake was accumulated in the roots which indicate that Co is less mobile in plants than Cs. (orig.) [de

  12. Point sources and multipoles in inverse scattering theory

    CERN Document Server

    Potthast, Roland

    2001-01-01

    Over the last twenty years, the growing availability of computing power has had an enormous impact on the classical fields of direct and inverse scattering. The study of inverse scattering, in particular, has developed rapidly with the ability to perform computational simulations of scattering processes and led to remarkable advances in a range of applications, from medical imaging and radar to remote sensing and seismic exploration. Point Sources and Multipoles in Inverse Scattering Theory provides a survey of recent developments in inverse acoustic and electromagnetic scattering theory. Focusing on methods developed over the last six years by Colton, Kirsch, and the author, this treatment uses point sources combined with several far-reaching techniques to obtain qualitative reconstruction methods. The author addresses questions of uniqueness, stability, and reconstructions for both two-and three-dimensional problems.With interest in extracting information about an object through scattered waves at an all-ti...

  13. UNDERWATER ANALYSIS OF IRRADIATED REACTOR SLUGS FOR Co-60 AND OTHER RADIONUCLIDES AT THE SAVANNAH RIVER SITE

    International Nuclear Information System (INIS)

    CASELLA, VITO

    2004-01-01

    Co-60 was produced in the Savannah River Site (SRS) reactors in the 1970s, and the irradiated cobalt reactor slugs were stored in a reactor basin at SRS. Since the activity rates of these slugs were not accurately known, assaying was required. A sodium iodide gamma detector was placed above a specially designed air collimator assembly, so that the slug was eight to nine feet from the detector and was shielded by the basin water. Also, 18 curium sampler slugs, used to produce Cm-244 from Pu-239, were to be disposed of with the cobalt slugs. The curium slugs were also analyzed with a High Purity Germanium (HPGE) detector in an attempt to identify any additional radionuclides produced from the irradiation. Co-60 concentrations were determined for reactor disassembly basin cobalt slugs and the 18 curium sampler slugs. The total Co-60 activity of all of the assayed slugs in this work summed to 31,783 curies on 9/15/03. From the Co-60 concentrations of the curium sampler slugs, the irradiation flux was determined for the known irradiation time. The amounts of Pu-238,-239,-240,-241,-242; Am-241,-243; and Cm-242,-244 produced were then obtained based on the original amount of Pu-239 irradiated

  14. Synthesis and characterization of mixtures of cobalt and titanium oxides by mechanical alloyed and Sol-Gel

    International Nuclear Information System (INIS)

    Basurto S, R.; Bonifacio M, J.; Fernandez V, S. M.

    2009-01-01

    The mechanical alloyed techniques continued by combustion and Sol-Gel method, were used for the synthesis of CoTiO 3 . With the first technique was used Co 3 O 4 obtained in a balls mill SPEX in argon atmosphere, using cobalt nitrate and urea, the combustion is realized at 400 and 500 C, the characterization by X-ray diffraction showed the obtaining of the valence oxide mixed of cobalt with crystallite size from 10 to 12.5 nm and the particle size of 60 to 75 nm was obtained by scanning electron microscopy. To prepare the CoTiO 3 , the obtained Co 3 O 4 was mixed with TiO 2 on a relationship in weight (1:1) and with a milling time of 2.5 h and the combustion at 800 C. the mixed oxide of titanium cobalt was also obtained by the Sol-Gel technique starting from cobalt chloride and titanium propoxide in acetic-water acid, the gel is burned to temperature of 300, 500, 700 and 900 C, finding that this last temperature it is that provides the compound with crystalline size from 50 to 75 nm. (Author)

  15. Nickel, cobalt, and their alloys

    CERN Document Server

    2000-01-01

    This book is a comprehensive guide to the compositions, properties, processing, performance, and applications of nickel, cobalt, and their alloys. It includes all of the essential information contained in the ASM Handbook series, as well as new or updated coverage in many areas in the nickel, cobalt, and related industries.

  16. The peak efficiency calibration of volume source using 152Eu point source in computer

    International Nuclear Information System (INIS)

    Shen Tingyun; Qian Jianfu; Nan Qinliang; Zhou Yanguo

    1997-01-01

    The author describes the method of the peak efficiency calibration of volume source by means of 152 Eu point source for HPGe γ spectrometer. The peak efficiency can be computed by Monte Carlo simulation, after inputting parameter of detector. The computation results are in agreement with the experimental results with an error of +-3.8%, with an exception one is about +-7.4%

  17. Speciation of cobalt-chloride-based ionic liquids and electrodeposition of Co wires

    International Nuclear Information System (INIS)

    Hsieh, Yi-Ting; Lai, Mei-Chun; Huang, Hsin-Liang; Sun, I.-Wen

    2014-01-01

    Highlights: • Template-free electrodeposition of cobalt nanowires arrays can be achieved from Lewis acidic CoCl 2 -EMIC ionic liquids. • SEM and TEM images reveal the diameter of the nanowire is around 200 nm, and the XPS data shows that cobalt oxide is formed at the surface of the nanowire. • MALDI-TOF-MS, XAS, and UV-vis spectroscopy results show that the coordination number and the mean Co-Cl bond length are depending on the molar ratio of CoCl 2 and EMIC. - Abstract: The speciation and coordination of cobalt-chloride-based ionic liquids with various mole percentages of CoCl 2 were investigated using matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF-MS), X-ray absorption spectroscopy (XAS), ultraviolet-visible absorption spectroscopy, and cyclic voltammetry. The coordination number and the mean Co-Cl bond length decreases with increasing CoCl 2 concentration, indicating that various Co(II) chloride compounds such as CoCl 4 2- , Co 2 Cl 5 - , and Co 3 Cl 7 − are formed depending on the molar ratio of CoCl 2 and EMIC in the melt. While the [CoCl 4 ] 2− complex formed in the Lewis basic melts and is electrochemically inactive within the electrochemical window of the melt, the other coordination-unsaturated cobalt chloride compounds formed in Lewis acidic melts can be electrochemically reduced to cobalt metal. The template-free electrodeposition of Co nanowires can be achieved from 40-60 mol% and 50-50 mol% CoCl 2 -EMIC (1-ethyl-3-methylimidazolium chloride) ionic liquids without any additives. Scanning electron microscopy (SEM), transmission electron microscopy (TEM), and X-ray photoelectron spectroscopy (XPS) were used to characterize the surface of the deposits

  18. Performance summary on a high power dense plasma focus x-ray lithography point source producing 70 nm line features in AlGaAs microcircuits

    International Nuclear Information System (INIS)

    Petr, Rodney; Bykanov, Alexander; Freshman, Jay; Reilly, Dennis; Mangano, Joseph; Roche, Maureen; Dickenson, Jason; Burte, Mitchell; Heaton, John

    2004-01-01

    A high average power dense plasma focus (DPF), x-ray point source has been used to produce ∼70 nm line features in AlGaAs-based monolithic millimeter-wave integrated circuits (MMICs). The DPF source has produced up to 12 J per pulse of x-ray energy into 4π steradians at ∼1 keV effective wavelength in ∼2 Torr neon at pulse repetition rates up to 60 Hz, with an effective x-ray yield efficiency of ∼0.8%. Plasma temperature and electron concentration are estimated from the x-ray spectrum to be ∼170 eV and ∼5·10 19 cm -3 , respectively. The x-ray point source utilizes solid-state pulse power technology to extend the operating lifetime of electrodes and insulators in the DPF discharge. By eliminating current reversals in the DPF head, an anode electrode has demonstrated a lifetime of more than 5 million shots. The x-ray point source has also been operated continuously for 8 h run times at 27 Hz average pulse recurrent frequency. Measurements of shock waves produced by the plasma discharge indicate that overpressure pulses must be attenuated before a collimator can be integrated with the DPF point source

  19. Manipulating radicals: Using cobalt to steer radical reactions

    OpenAIRE

    Chirilă, A.

    2017-01-01

    This thesis describes research aimed at understanding and exploiting metallo-radical reactivity and explores reactions mediated by square planar, low-spin cobalt(II) complexes. A primary goal was to uncover novel reactivity of discrete cobalt(III)-bound carbene radicals generated upon reaction of the cobalt(II) catalysts with carbene precursors. Another important goal was to replace cobalt(II)-porphyrin catalysts with cheaper and easier to prepare metallo-radical analogues. Therefore the cata...

  20. X-ray fluorescence determination of cobalt in iron-manganese oceanic concretions

    International Nuclear Information System (INIS)

    Ivanenko, V.V.; Kustov, V.N.; Metelev, A.Yu.; Rakita, K.A.

    1989-01-01

    A method was developed for resolution of weak analytical lines for elements determined by radionuclide-excited X-ray fluorescence multi-element analysis. The method was used aboart for determining cobalt and some other commercially valuable elements in iron-manganese concretions of Pacific ocean 109 Cd was used as an ionizing radiation source

  1. Study of the 60Co speciation in the aqueous radioactive waste of the la Hague nuclear reprocessing plant; environmental behaviour after discharges in the waters of the channel

    International Nuclear Information System (INIS)

    Gaudaire, J.M.

    1999-01-01

    60 Co is produced as an activation product and is present in the low-level aqueous radioactive waste released from the La Hague plant. At present, the concentration in the sea (non filtered at 0.45 μm) at the Goury site are close to or even below, the detection limit: 0.2 mBq.l -1 . The 60 Co speciation depends on the type of effluent considered: in the effluent A ('active'), the cobalt is in the form of a stable trivalent complex; in the effluent V (to be checked), the cobalt is in majority (50% of the activity release) in the form of particles (>0.45 μm), and then in the form of two soluble species: ionic divalent (Co 2+ ) and some stable complexes. The evolution of the reprocessing techniques used does not affect the speciation. So, since the nuclear reprocessing plant started at the La Hague plant in 1966, the chemical species discharged in the sea shows time variation related to the evolution of the type of effluent discharged. Thus, since 1994, the particles of cobalt are the main species discharged in the Channel (the V effluents represent more than 85% of the total 60 Co activity released). The effect of instantaneous dilution into the marine conditions involving a variation of pH, oxido-reduction, ionic strength, a gradient of salinity, does not interfere with the evolution of the chemical species discharged. Nevertheless, during the discharge of the V effluent, the main constituents of the sea water (Mg 2+ and Ca 2+ ) go through a precipitation. This comes with the coprecipitation of the ion Co 2+ and with the particles of cobalt (complexes are not affected), and it can be responsible for an increase in the concentration in the particles. The chemical behaviour of the cobalt in the Channel is different from those of conservative element such as antimony. The ionic cobalt and the particles have a small dispersion in the water (cobalt has a very high particle/dissolved distribution factor, it is a non-conservative radionuclide). This sedimentary stock can

  2. Relaxation resistance of heat resisting alloys with cobalt

    International Nuclear Information System (INIS)

    Borzdyka, A.M.

    1977-01-01

    Relaxation resistance of refractory nickel-chromium alloys containing 5 to 14 % cobalt is under study. The tests involve the use of circular samples at 800 deg to 850 deg C. It is shown that an alloy containing 14% cobalt possesses the best relaxation resistance exceeding that of nickel-chromium alloys without any cobalt by a factor of 1.5 to 2. The relaxation resistance of an alloy with 5% cobalt can be increased by hardening at repeated loading

  3. Optical identifications of IRAS point sources: the Fornax, Hydra I and Coma clusters

    International Nuclear Information System (INIS)

    Wang, G.; Leggett, S.K.; Savage, A.

    1991-01-01

    We present optical identifications for 66 IRAS point sources in the region of the Fornax cluster of galaxies, 106 IRAS point sources in the region of the Hydra I cluster of galaxies (Abell 1060) and 59 IRAS point sources in the region of the Coma cluster of galaxies (Abell 1656). Eight other sources in Hydra I do not have optical counterparts and are very probably due to infrared cirrus. Twenty-three (35 per cent) of the Fornax sources are associated with stars and 43 (65 per cent) with galaxies; 48 (42 per cent) of the Hydra I sources are associated with stars and 58 (51 per cent) with galaxies; 18 (31 per cent) of the Coma sources are associated with stars and 41 (69 per cent) with galaxies. The stellar and infrared cirrus surface density is consistent with the galactic latitude of each field. (author)

  4. LOWERING ICECUBE'S ENERGY THRESHOLD FOR POINT SOURCE SEARCHES IN THE SOUTHERN SKY

    Energy Technology Data Exchange (ETDEWEB)

    Aartsen, M. G. [Department of Physics, University of Adelaide, Adelaide, 5005 (Australia); Abraham, K. [Physik-department, Technische Universität München, D-85748 Garching (Germany); Ackermann, M. [DESY, D-15735 Zeuthen (Germany); Adams, J. [Department of Physics and Astronomy, University of Canterbury, Private Bag 4800, Christchurch (New Zealand); Aguilar, J. A.; Ansseau, I. [Université Libre de Bruxelles, Science Faculty CP230, B-1050 Brussels (Belgium); Ahlers, M. [Department of Physics and Wisconsin IceCube Particle Astrophysics Center, University of Wisconsin, Madison, WI 53706 (United States); Ahrens, M. [Oskar Klein Centre and Department of Physics, Stockholm University, SE-10691 Stockholm (Sweden); Altmann, D.; Anton, G. [Erlangen Centre for Astroparticle Physics, Friedrich-Alexander-Universität Erlangen-Nürnberg, D-91058 Erlangen (Germany); Andeen, K. [Department of Physics, Marquette University, Milwaukee, WI, 53201 (United States); Anderson, T.; Arlen, T. C. [Department of Physics, Pennsylvania State University, University Park, PA 16802 (United States); Archinger, M.; Baum, V. [Institute of Physics, University of Mainz, Staudinger Weg 7, D-55099 Mainz (Germany); Arguelles, C. [Department of Physics, Massachusetts Institute of Technology, Cambridge, MA 02139 (United States); Auffenberg, J. [III. Physikalisches Institut, RWTH Aachen University, D-52056 Aachen (Germany); Bai, X. [Physics Department, South Dakota School of Mines and Technology, Rapid City, SD 57701 (United States); Barwick, S. W. [Department of Physics and Astronomy, University of California, Irvine, CA 92697 (United States); Bay, R., E-mail: jacob.feintzeig@gmail.com, E-mail: naoko@icecube.wisc.edu [Department of Physics, University of California, Berkeley, CA 94720 (United States); Collaboration: IceCube Collaboration; and others

    2016-06-20

    Observation of a point source of astrophysical neutrinos would be a “smoking gun” signature of a cosmic-ray accelerator. While IceCube has recently discovered a diffuse flux of astrophysical neutrinos, no localized point source has been observed. Previous IceCube searches for point sources in the southern sky were restricted by either an energy threshold above a few hundred TeV or poor neutrino angular resolution. Here we present a search for southern sky point sources with greatly improved sensitivities to neutrinos with energies below 100 TeV. By selecting charged-current ν{sub μ} interacting inside the detector, we reduce the atmospheric background while retaining efficiency for astrophysical neutrino-induced events reconstructed with sub-degree angular resolution. The new event sample covers three years of detector data and leads to a factor of 10 improvement in sensitivity to point sources emitting below 100 TeV in the southern sky. No statistically significant evidence of point sources was found, and upper limits are set on neutrino emission from individual sources. A posteriori analysis of the highest-energy (∼100 TeV) starting event in the sample found that this event alone represents a 2.8 σ deviation from the hypothesis that the data consists only of atmospheric background.

  5. Equilibrium sorption of cobalt, cesium, and strontium on Bandelier Tuff: analysis of alternative mathematical modeling

    International Nuclear Information System (INIS)

    Polzer, W.L.; Fuentes, H.R.; Essington, E.H.; Roensch, F.R.

    1985-01-01

    Sorption isotherms are derived from batch equilibrium data for cobalt, cesium and strontium on Bandelier Tuff. Experiments were conducted at an average temperature of 23 0 C and equilibrium was defined at 48 hours. The solute concentrations ranged from 0 to 500 mg/L. The radioactive isotopes 60 Co, 137 Cs, and 85 Sr were used to trace the sorption of the stable solutes. The Linear, Langmuir, Freundlich and a Modified Freundlich isotherm equations are evaluated. The Modified Freundlich isotherm equation is validated as a preferred general mathematical tool for representing the sorption of the three solutes. The empirical constants derived from the Modified Freundlich isotherm equation indicate that under dynamic flow conditions strontium will move most rapidly and cobalt least rapidly. On the other hand, chemical dispersion will be greatest for cesium and least for strontium. Hill Plots of the sorption data suggest that in the region of low saturation sorption of all three solutes is impeded by interactions among sorption sites; cobalt exhibits the greatest effect of interactions and strontium shows only a minimal effect. In the saturation region of 50% or more, sorption of cobalt is enhanced slightly by interactions among sorption sites whereas sorption of cesium and strontium appears to be independent of site interactions. 9 references, 4 figures, 2 tables

  6. A Measurement and Analysis of Buildup Region Dose for Open Field Photon Beams (Cobalt-60 through 24 MV)

    International Nuclear Information System (INIS)

    McCullough, Edwin C.

    2015-01-01

    The central axis depth dose in the build-up region (surface to d_m_a_x) of single open field photon beams (cobalt-60 through 24 MV) has been measured utilizing parallel plate and extrapolation chamber methodology. These data were used to derive, for a prescription dose of 100 cGy, values of surface dose, the maximum value of dose along the central axis (D_m_a_x) and the depth (nearest the surface) at which 90% of the prescription dose occurs (d_9_0). For both single and parallel opposed pair (POP) open field configurations, data are presented at field sizes of 5 × 5, 15 × 15 and 25 × 25 cm"2 for prescription depths of 10, 15 and 20 cm (midplane for POP). For the treatment machines, field sizes, and prescription depths studied, it is possible to conclude that: for single open field irradiation, surface dose values (as a percentage of the prescription dose) can be either low (<10%) or comparable to the prescription dose itself; for POP open fields, surface dose values are relatively independent of photon energy and midplane depth, and range between 30% and 70% of prescription dose, being principally dependent on field size; the depth of the initial 90 cGy point for a prescription dose of 100 cGy, d_9_0, was larger for POP fields. For either single or POP open field treatments, d_9_0 was always less than 22 mm, while for 6 MV or less, values of d_9_0 were less than 4 mm; D_m_a_x values can be very large (e.g., above 300 cGy) for certain treatment situations and are reduced significantly for POP treatments; for open field POP treatments, the percent reduction in D_m_a_x with each increment in beam energy above 10 MV is reduced over that seen at 10 MV or less and, possibly, this further reduction may be clinically insignificant; for open field POP treatments, changes in surface dose, d_9_0 and D_m_a_x with beam energy above 10 MV do not suggest, with regard to these specific build-up curve parameters, any obvious advantage for treatment with beam energies greater

  7. Heating-induced inner-sphere substitution and reduction-oxidation reactions of the solid phenanthroline containing cobalt (2) and cobalt (3) complexes

    International Nuclear Information System (INIS)

    Palade, D.M.

    1996-01-01

    The results of the differential thermal and thermogravimetric analyses of solid phenanthroline-containing complexes of cobalt (2) and cobalt (3) in the atmosphere of the air have been analyzed. Mechanism of redox reactions occurring when cobalt (3) complexes are heated has been discussed. It is shown that some of gaseous products of the redox processes appear as a result of secondary reactions and not the processes of the ligands oxidation by Co 3+ . The influence of certain inner-sphere and coordinated anions (of I, inclusively) on cobalt (3) complexes behaviour during heating has been considered

  8. Progeny of Spalangia endius Walker, 1839 (Hymenoptera: Pteromalidae) in Musca domestica L., 1758 (Diptera: Muscidae) non-viable pupae irradiated by gamma Cobalt-60 and cold stored

    International Nuclear Information System (INIS)

    Itepan, Sara Eloiza Zen.

    1992-06-01

    This study was designed to test acceptability of cold stored irradiated and non-irradiated pupae of Musca domestica L., 1758 (Diptera: Muscidae) by the parasitoid Spalangia endius Walker, 1839 (Hymenoptera: Pteromalidae). The work was carried out in the laboratory of the Entomology Section of the Center of Nuclear Energy in Agriculture (CENA/USP) and in the laboratory of Biological Control of House Flies Eduardo Hiroshi Mizumoto of Entomology Department of the College of Agriculture Luiz de Queiroz (ESALQ/USP), Piracicaba, Sao Paulo, Brazil. The gamma radiation source used was a Cobalt-60 irradiator, Gamma bean-650, with an initial activity of 1,6265 x 10 4 Bq (6,746 Ci). The radiation LD 50 e LD 100 , using a dose ratio of 1457 Gy/h, for 12, 24, 36, 48, 60 and 72 hours old pupae and resulted in 15.35; 15.69; 11.30; 49.4; 142.78 and 175 Gy for LD 50 and 20, 22.5; 32.5; 175; 225 and 300 Gy for LD'1 00 respectively. Following exposure, the pupae were kept in climate chamber at 27 ± 3 0 C and 75 ± % of relative humidity, until all adults had emerged. In succession, 24, 48 and 72 hour-old pupae were exposed to gamma irradiation with a dose of 1440 Gy/hour, in their respective lethal doses. Following the exposure the pupae were stored at cool temperature (10 ± 2 0 C) for different periods of time (5, 15, 20 and 30 days). The same treatment was given for non-irradiated pupae. After the storage period the pupae were expose for 24 h to S. endius in a ratio of 1:10 parasitoid-host. It was not observed any statistical difference (Turkey 5%) in progeny of males and females emerged from irradiated and non-irradiated pupae. There was a preference of the parasitoid to pupae of 48 hours old followed by 24 and 72 hours old for storage period more than 5 days and shorter than 20 days. (author). 50 refs., 6 figs., 17 tabs

  9. Guide for the preparation of applications for licenses for the use of self-contained dry source-storage irradiators. Second proposed Revision 1

    International Nuclear Information System (INIS)

    Bassin, N.

    1984-10-01

    The purpose of this regulatory guide is to provide assistance to applicants and licensees in preparing applications for new licenses, license amendments, and license renewals for the use of self-contained dry source-storage irradiators. These irradiators are constructed so that the sealed sources and the material being irradiated are contained in a shielded volume and there is no external radiation beam during the use of the irradiator. The radioisotopes most commonly used for these irradiators are cobalt-60 and cesium-137

  10. Control of carbon nanotube growth using cobalt nanoparticles as catalyst

    International Nuclear Information System (INIS)

    Huh, Yoon; Green, Malcolm L.H.; Kim, Young Heon; Lee, Jeong Yong; Lee, Cheol Jin

    2005-01-01

    We have controllably grown carbon nanotubes using uniformly distributed cobalt nanoparticles as catalyst. Cobalt nanoparticles with a uniform size were synthesized by chemical reaction and colloidal solutions including the cobalt nanoparticles were prepared. The cobalt nanoparticles were uniformly distributed on silicon substrates by a spin-coating method. Carbon nanotubes with a uniform diameter were synthesized on the cobalt nanoparticles by thermal chemical vapor deposition of acetylene gas. The density and vertical alignment of carbon nanotubes could be controlled by adjusting the density of cobalt (Co) nanoparticles

  11. Radioprotective activity of curcumin-encapsulated liposomes against genotoxicity caused by Gamma Cobalt-60 irradiation in human blood cells.

    Science.gov (United States)

    Nguyen, Minh-Hiep; Pham, Ngoc-Duy; Dong, Bingxue; Nguyen, Thi-Huynh-Nga; Bui, Chi-Bao; Hadinoto, Kunn

    2017-11-01

    While the radioprotective activity of curcumin against genotoxicity has been well established, its poor oral bioavailability has limited its successful clinical applications. Nanoscale formulations, including liposomes, have been demonstrated to improve curcumin bioavailability. The objective of the present work was (1) to prepare and characterize curcumin-encapsulated liposomes (i.e. size, colloidal stability, encapsulation efficiency, and payload), and (2) subsequently to evaluate their radioprotective activity against genotoxicity in human blood cells caused by Gamma Cobalt-60 irradiation. The curcumin-encapsulated liposomes were prepared by lipid-film hydration method using commercial phosphatidylcholine (i.e. Phospholipon ® 90G). The blood cells were obtained from healthy male donors (n = 3) under an approved ethics protocol. The cell uptake and the radioprotective activity of the curcumin-encapsulated liposomes were characterized by fluorescence microscopy and micronucleus assay, respectively. Nanoscale curcumin-encapsulated liposomes exhibiting good physical characteristics and successful uptake by the human blood cells were successfully prepared. The radioprotective activity of the curcumin-encapsulated liposomes was found to be dependent on the curcumin concentration, where an optimal concentration existed (i.e. 30 μg/mL) independent of the irradiation dose, above which the radioprotective activity had become stagnant (i.e. no more reduction in the micronuclei frequency). The present results established for the first time the radioprotective activity of curcumin-encapsulated liposomes in human blood cells, which coupled by its well-established bioavailability, boded well for its potential application as a nanoscale delivery system of other radioprotective phytochemicals.

  12. Inadvertent shipment of a radiographic source from Korea to Amersham Corporation, Burlington, Massachusetts

    International Nuclear Information System (INIS)

    1990-05-01

    Amersham Corporation, Burlington, Massachusetts, a licensee of the US Nuclear Regulatory Commission (NRC), authorized to manufacture and distribute iridium-192 and cobalt-60 source assemblies for use in radiography equipment, received a shipment of 14 source changer son March 8, 1990, that were being returned from their product distributor, NDI Corporation in Seoul, Korea. One source changer contained a small sealed source in an unshielded location. Amersham employees retrieved the source, secured it in a hot cell, and notified NRC's Region I. Subsequently, NRC dispatched an Incident Investigation Team to perform a comprehensive review of this incident and determine the potential for exposure to those who handled the source changer and to members of the general public. This report describes the incident and the methodology used in the investigation and presents the Team's findings and conclusions

  13. Dosing of anaerobic granular sludge bioreactors with cobalt: Impact of cobalt retention on methanogenic activity

    KAUST Repository

    Fermoso, Fernando G.

    2010-12-01

    The effect of dosing a metal limited anaerobic sludge blanket (UASB) reactor with a metal pulse on the methanogenic activity of granular sludge has thus far not been successfully modeled. The prediction of this effect is crucial in order to optimize the strategy for metal dosage and to prevent unnecessary losses of resources. This paper describes the relation between the initial immobilization of cobalt in anaerobic granular sludge cobalt dosage into the reactor and the evolution of methanogenic activity during the subsequent weeks. An operationally defined parameter (A0· B0) was found to combine the amount of cobalt immobilized instantaneously upon the pulse (B0) and the amount of cobalt immobilized within the subsequent 24. h (A0). In contrast with the individual parameters A0 and B0, the parameter A0· B0 correlated significantly with the methanogenic activity of the sludge during the subsequent 16 or 35. days. This correlation between metal retention and activity evolution is a useful tool to implement trace metal dosing strategies for biofilm-based biotechnological processes. © 2010.

  14. Cobalt(II) and Cobalt(III) Coordination Compounds.

    Science.gov (United States)

    Thomas, Nicholas C.; And Others

    1989-01-01

    Presents a laboratory experiment which illustrates the formation of tris(phenanthroline)cobalt complexes in the 2+ and 3+ oxidation states, the effect of coordination on reactions of the ligand, and the use of a ligand displacement reaction in recovering the transformed ligand. Uses IR, UV-VIS, conductivity, and NMR. (MVL)

  15. Desorption of Sr 89, Co 60 and Cs 134 from Suez Canal bottom sediments (Port Tawfeek Area)

    International Nuclear Information System (INIS)

    El-Assy, N.B.; Abdel-Fattah, A.T.; El-Shinawy, R.M.K.; Essa, M.W.A.

    1986-01-01

    Chemical and physical properties of Suez Canal Bottom Sediments (S.C.B.S) and seawater at Port Tawfeek, the south entrance of Suez Canal, were studied. The (S.C.B.S) was separated into its size fractions (natural sediment, sand, silt and clay). These different sediment fractions were allowed to be in equilibrium with Strontium 89, Cobalt 60 and Cesium 134 solutions. Desorption studies were carried out on these contaminated sediments. The release of Strontium 89 and Cesium 134 was found to be identical and the sequence of this release was as follows : sand> silt> natural sediment> clay. The effect of seawater is 6-8 times that of bidistilled water. In case of Cobalt 60 the above sequence was disturbed and the salinity effect was only 2 times that of bidistilled water. It was also found that Strontium and Cobalt were more easily desorbed from the sand fraction a behaviour which can be explained by their loose attachment to the crystal surface

  16. Assessment of nickel and cobalt release from 200 unused hand-held work tools for sale in Denmark - Sources of occupational metal contact dermatitis?

    DEFF Research Database (Denmark)

    Thyssen, Jacob P; Jensen, Peter; Lidén, Carola

    2011-01-01

    Nickel and cobalt allergy remain frequent in dermatitis patients. It is important to determine possible nickel and cobalt exposures at work as these may offer important information to regulators and physicians who perform patch testing. Clinical relevance of metal exposure is usually assessed...

  17. A thermodynamic and kinetic study of trace iron removal from aqueous cobalt sulfate solutions using Monophos resin.

    Science.gov (United States)

    Wang, Guangxin; Zhao, Yunchao; Yang, Bin; Song, Yongfa

    2018-01-01

    High purity cobalt has many important applications, such as magnetic recording media, magnetic recording heads, optoelectronic devices, magnetic sensors, and integrated circuits, etc. To produce 5N or higher purity cobalt in an electro-refining process, one of the challenges is to effectively reduce the Fe content of aqueous cobalt salt solution before electrolysis. This paper describes thermodynamic and kinetic investigations of the Fe adsorption process of a new sulfonated monophosphonic resin with the trade mark Monophos. Five cobalt sulfate solutions of different Co concentrations were prepared. Fe ions were removed from the solutions by ion exchange method using Monophos resin. Chemical analysis was carried out using a Perkin Elmer ICP-OES. The initial Fe concentrations of about 0.9-2.0 mg/L can be reduced to about 0.3-0.8 mg/L, which is equivalent to an Fe removal rate of 60-67%. The Langmuir isothermal adsorption model applies well to the Fe removal process. A second-order type based on McKay equation fits better with experimental data than other kinetic models. The kinetic curve can be divided into two sections. For t 30 min. Monophos resin is effective for the removal of trace Fe from cobalt sulfate solution. This ion exchange process obeys the Langmuir isothermal adsorption model and the McKay equation of second-order kinetics.

  18. Recovery of lithium and cobalt from waste lithium ion batteries of mobile phone.

    Science.gov (United States)

    Jha, Manis Kumar; Kumari, Anjan; Jha, Amrita Kumari; Kumar, Vinay; Hait, Jhumki; Pandey, Banshi Dhar

    2013-09-01

    In view of the stringent environmental regulations, availability of limited natural resources and ever increasing need of alternative energy critical elements, an environmental eco-friendly leaching process is reported for the recovery of lithium and cobalt from the cathode active materials of spent lithium-ion batteries of mobile phones. The experiments were carried out to optimize the process parameters for the recovery of lithium and cobalt by varying the concentration of leachant, pulp density, reductant volume and temperature. Leaching with 2M sulfuric acid with the addition of 5% H(2)O(2) (v/v) at a pulp density of 100 g/L and 75°C resulted in the recovery of 99.1% lithium and 70.0% cobalt in 60 min. H(2)O(2) in sulfuric acid solution acts as an effective reducing agent, which enhance the percentage leaching of metals. Leaching kinetics of lithium in sulfuric acid fitted well to the chemical controlled reaction model i.e. 1-(1-X)(1/3)=k(c)t. Leaching kinetics of cobalt fitted well to the model 'ash diffusion control dense constant sizes spherical particles' i.e. 1-3(1-X)(2/3)+2(1-X)=k(c)t. Metals could subsequently be separated selectively from the leach liquor by solvent extraction process to produce their salts by crystallization process from the purified solution. Copyright © 2013 Elsevier Ltd. All rights reserved.

  19. 40 CFR 437.11 - Effluent limitations attainable by the application of the best practicable control technology...

    Science.gov (United States)

    2010-07-01

    ... CENTRALIZED WASTE TREATMENT POINT SOURCE CATEGORY Metals Treatment and Recovery § 437.11 Effluent limitations... (2) (2) TSS 60.0 31.0 Metal Parameters Antimony 0.249 0.206 Arsenic 0.162 0.104 Cadmium 0.474 0.0962 Chromium 15.5 3.07 Cobalt 0.192 0.124 Copper 4.14 1.06 Lead 1.32 0.283 Mercury 0.00234 0.000739 Nickel 3.95...

  20. Extraction of cobalt ion from textile using a complexing macromolecular surfactant in supercritical carbon dioxide

    International Nuclear Information System (INIS)

    Chirat, Mathieu; Ribaut, Tiphaine; Clerc, Sebastien; Lacroix-Desmazes, Patrick; Charton, Frederic; Fournel, Bruno

    2013-01-01

    Cobalt ion under the form of cobalt nitrate is removed from a textile lab coat using supercritical carbon dioxide extraction. The process involves a macromolecular additive of well-defined architecture, acting both as a surfactant and a complexing agent. The extraction efficiency of cobalt reaches 66% when using a poly(1,1,2,2-tetrahydroperfluoro-decyl-acrylate-co-vinyl-benzylphosphonic diacid) gradient copolymer in the presence of water at 160 bar and 40 C. The synergy of the two additives, namely the copolymer and water which are useless if used separately, is pointed out. The potential of the supercritical carbon dioxide process using complexing macromolecular surfactant lies in the ability to modulate the complexing unit as a function of the metal as well as the architecture of the surface-active agent for applications ranging for instance from nuclear decontamination to the recovery of strategic metals. (authors)