WorldWideScience

Sample records for cobalt-60 plaque radiotherapy

  1. Cobalt60 plaques in recurrent retinoblastoma

    Energy Technology Data Exchange (ETDEWEB)

    Fass, D.; McCormick, B.; Abramson, D.; Ellsworth, R. (Department of Radiation Oncology, Memorial Sloan-Kettering Cancer Center, NY, NY (USA))

    1991-08-01

    Cobalt60 plaque irradiation is one treatment option for patients with recurrent retinoblastoma following conventional external beam irradiation (ERT). Tumorocidal doses can be delivered without excessive risk of normal tissue injury. In patients not considered candidates for xenon arc or cryotherapy, 60Co is an alternative to enucleation. Between 1968 and 1987, 85 patients were treated with 60Co plaques, 72 of whom had failed prior ERT. Age at diagnosis ranged from 1 week to 4 years. There are 37 males and 35 females. Seventy-one patients had bilateral disease and one had unilateral. Three patients had both eyes plaqued. Prior ERT ranged from 30 to 70 Gy (mean 4200 Gy). Time from initial therapy to failure ranged from 13 to 60 months. Cobalt plaques of 10 mm, 15 mm, or 10 {times} 15 mm were used depending on tumor size and location. Dose prescribed to the apex of the tumor ranged from 30 to 50 Gy (median 40 Gy) given over 3 to 8 days. Twelve patients had two plaque applications; three patients had three plaque applications. All patients were followed with routine ophthalmoscopic examinations. Follow-up ranged from 2 to 22 years (mean 8.7). Seven patients died of metastatic disease; 10 patients developed non-ocular second tumors. Thirty patients required enucleation. Twenty-two patients had clear tumor progression, two patients had radiation complications, and six patients had a combination of tumor growth and complications. Cobalt60 can salvage eyes in retinoblastoma patients failing ERT. Currently, the authors are using I125 in an attempt to spare normal ocular tissue and reduce subsequent complications.

  2. Cobalt60 plaques in recurrent retinoblastoma

    International Nuclear Information System (INIS)

    Fass, D.; McCormick, B.; Abramson, D.; Ellsworth, R.

    1991-01-01

    Cobalt60 plaque irradiation is one treatment option for patients with recurrent retinoblastoma following conventional external beam irradiation (ERT). Tumorocidal doses can be delivered without excessive risk of normal tissue injury. In patients not considered candidates for xenon arc or cryotherapy, 60Co is an alternative to enucleation. Between 1968 and 1987, 85 patients were treated with 60Co plaques, 72 of whom had failed prior ERT. Age at diagnosis ranged from 1 week to 4 years. There are 37 males and 35 females. Seventy-one patients had bilateral disease and one had unilateral. Three patients had both eyes plaqued. Prior ERT ranged from 30 to 70 Gy (mean 4200 Gy). Time from initial therapy to failure ranged from 13 to 60 months. Cobalt plaques of 10 mm, 15 mm, or 10 x 15 mm were used depending on tumor size and location. Dose prescribed to the apex of the tumor ranged from 30 to 50 Gy (median 40 Gy) given over 3 to 8 days. Twelve patients had two plaque applications; three patients had three plaque applications. All patients were followed with routine ophthalmoscopic examinations. Follow-up ranged from 2 to 22 years (mean 8.7). Seven patients died of metastatic disease; 10 patients developed non-ocular second tumors. Thirty patients required enucleation. Twenty-two patients had clear tumor progression, two patients had radiation complications, and six patients had a combination of tumor growth and complications. Cobalt60 can salvage eyes in retinoblastoma patients failing ERT. Currently, the authors are using I125 in an attempt to spare normal ocular tissue and reduce subsequent complications

  3. Cobalt-60 Machines and Medical Linear Accelerators: Competing Technologies for External Beam Radiotherapy.

    Science.gov (United States)

    Healy, B J; van der Merwe, D; Christaki, K E; Meghzifene, A

    2017-02-01

    Medical linear accelerators (linacs) and cobalt-60 machines are both mature technologies for external beam radiotherapy. A comparison is made between these two technologies in terms of infrastructure and maintenance, dosimetry, shielding requirements, staffing, costs, security, patient throughput and clinical use. Infrastructure and maintenance are more demanding for linacs due to the complex electric componentry. In dosimetry, a higher beam energy, modulated dose rate and smaller focal spot size mean that it is easier to create an optimised treatment with a linac for conformal dose coverage of the tumour while sparing healthy organs at risk. In shielding, the requirements for a concrete bunker are similar for cobalt-60 machines and linacs but extra shielding and protection from neutrons are required for linacs. Staffing levels can be higher for linacs and more staff training is required for linacs. Life cycle costs are higher for linacs, especially multi-energy linacs. Security is more complex for cobalt-60 machines because of the high activity radioactive source. Patient throughput can be affected by source decay for cobalt-60 machines but poor maintenance and breakdowns can severely affect patient throughput for linacs. In clinical use, more complex treatment techniques are easier to achieve with linacs, and the availability of electron beams on high-energy linacs can be useful for certain treatments. In summary, there is no simple answer to the question of the choice of either cobalt-60 machines or linacs for radiotherapy in low- and middle-income countries. In fact a radiotherapy department with a combination of technologies, including orthovoltage X-ray units, may be an option. Local needs, conditions and resources will have to be factored into any decision on technology taking into account the characteristics of both forms of teletherapy, with the primary goal being the sustainability of the radiotherapy service over the useful lifetime of the equipment

  4. Regression of uveal malignant melanomas following cobalt-60 plaque. Correlates between acoustic spectrum analysis and tumor regression

    International Nuclear Information System (INIS)

    Coleman, D.J.; Lizzi, F.L.; Silverman, R.H.; Ellsworth, R.M.; Haik, B.G.; Abramson, D.H.; Smith, M.E.; Rondeau, M.J.

    1985-01-01

    Parameters derived from computer analysis of digital radio-frequency (rf) ultrasound scan data of untreated uveal malignant melanomas were examined for correlations with tumor regression following cobalt-60 plaque. Parameters included tumor height, normalized power spectrum and acoustic tissue type (ATT). Acoustic tissue type was based upon discriminant analysis of tumor power spectra, with spectra of tumors of known pathology serving as a model. Results showed ATT to be correlated with tumor regression during the first 18 months following treatment. Tumors with ATT associated with spindle cell malignant melanoma showed over twice the percentage reduction in height as those with ATT associated with mixed/epithelioid melanomas. Pre-treatment height was only weakly correlated with regression. Additionally, significant spectral changes were observed following treatment. Ultrasonic spectrum analysis thus provides a noninvasive tool for classification, prediction and monitoring of tumor response to cobalt-60 plaque

  5. Research about combination of Gamma Knife and cobalt-60 radiation therapy to treat hypophysoma

    International Nuclear Information System (INIS)

    Xing Yueming; Zhao Xinping; Song Xiang; Wu Wei; Huang Bai

    2003-01-01

    Objective: To probe the therapeutic effectiveness of combination of Gamma Knife and cobalt-60 radiotherapy. Methods: 80 Hypophysoma patients who have been randomly grouped into two groups. Combination of Gamma Knife and cobalt-60 radiotherapy group and single Gamma knife group. Results: The therapeutic effectiveness of combination of Gamma Knife and cobalt-60 radiation therapy group was higher than that of single Gamma Knife group. Conclusion: The hospital that treat Hypophysoma with single Gamma Knife should add cobalt-60 radiotherapy in order to increase the local Hypophysoma dose

  6. Radiation regression patterns after cobalt plaque insertion for retinoblastoma

    International Nuclear Information System (INIS)

    Buys, R.J.; Abramson, D.H.; Ellsworth, R.M.; Haik, B.

    1983-01-01

    An analysis of 31 eyes of 30 patients who had been treated with cobalt plaques for retinoblastoma disclosed that a type I radiation regression pattern developed in 15 patients; type II, in one patient, and type III, in five patients. Nine patients had a regression pattern characterized by complete destruction of the tumor, the surrounding choroid, and all of the vessels in the area into which the plaque was inserted. This resulting white scar, corresponding to the sclerae only, was classified as a type IV radiation regression pattern. There was no evidence of tumor recurrence in patients with type IV regression patterns, with an average follow-up of 6.5 years, after receiving cobalt plaque therapy. Twenty-nine of these 30 patients had been unsuccessfully treated with at least one other modality (ie, light coagulation, cryotherapy, external beam radiation, or chemotherapy)

  7. Radiation regression patterns after cobalt plaque insertion for retinoblastoma

    Energy Technology Data Exchange (ETDEWEB)

    Buys, R.J.; Abramson, D.H.; Ellsworth, R.M.; Haik, B.

    1983-08-01

    An analysis of 31 eyes of 30 patients who had been treated with cobalt plaques for retinoblastoma disclosed that a type I radiation regression pattern developed in 15 patients; type II, in one patient, and type III, in five patients. Nine patients had a regression pattern characterized by complete destruction of the tumor, the surrounding choroid, and all of the vessels in the area into which the plaque was inserted. This resulting white scar, corresponding to the sclerae only, was classified as a type IV radiation regression pattern. There was no evidence of tumor recurrence in patients with type IV regression patterns, with an average follow-up of 6.5 years, after receiving cobalt plaque therapy. Twenty-nine of these 30 patients had been unsuccessfully treated with at least one other modality (ie, light coagulation, cryotherapy, external beam radiation, or chemotherapy).

  8. Dosimetric intercomparison in Cobalt 60 unities using TLD-100 crystals and CaSO4: Dy + Ptfe

    International Nuclear Information System (INIS)

    Gaona, E.; Azorin N, J.; Perez P, M.A.; Castillo H, M.; Flores F, F.; Guzman R, L.V.

    1999-01-01

    The purpose of this work is to design and construct a phantom in basis of thermoplastic polymer of methyl methacrylate that is reutilizable and which allows to do an analysis of the absorbed doses in thermoluminescent crystals (Tl) exposed to cobalt 60 to establish the dosimetric intercomparison in cobalt units which allows to do the follow-up of the Quality assurance programs, standardization of calibration procedures, dosimetry and TLD post intercomparison in radiotherapy. This work allows also prove new thermoluminescent materials of national manufacture developed by Juan Azorin and collaborators as the CaSO 4 : Dy + Ptfe. This is a first study which is realized in Mexico with the system crystal-phantom for aims to intercomparison in cobalt 60 units. In this work participate eight unities of cobalt 60 of different trades belonging at four radiotherapy centers. The results of the dose intercomparison of the eight unities of cobalt 60 were in the range 0.95-1.13, taking in account that the values between 0.95 and 1.05 were considered acceptable in terms of the requirements by the standing legislation. (Author)

  9. Cobalt-60 production in CANDU power reactors

    International Nuclear Information System (INIS)

    Slack, J.; Norton, J.L.; Malkoske, G.R.

    2003-01-01

    MDS Nordion has been supplying cobalt-60 sources to industry for industrial and medical purposes since 1946. These cobalt-60 sources are used in many market and product segments. The major application is in the health care industry where irradiators are used to sterilize single use medical products. These irradiators are designed and built by MDS Nordion and are used by manufacturers of surgical kits, gloves, gowns, drapes and other medical products. The irradiator is a large shielded room with a storage pool for the cobalt-60 sources. The medical products are circulated through the shielded room and exposed to the cobalt-60 sources. This treatment sterilizes the medical products which can then be shipped to hospitals for immediate use. Other applications for this irradiation technology include sanitisation of cosmetics, microbial reduction of pharmaceutical raw materials and food irradiation. The cobalt-60 sources are manufactured by MDS Nordion in their Cobalt Operations Facility in Kanata. More than 75,000 cobalt-60 sources for use in irradiators have been manufactured by MDS Nordion. The cobalt-60 sources are double encapsulated in stainless steel capsules, seal welded and helium leak tested. Each source may contain up to 14,000 curies. These sources are shipped to over 170 industrial irradiators around the world. This paper will focus on the MDS Nordion proprietary technology used to produce the cobalt-60 isotope in CANDU reactors. Almost 55 years ago MDS Nordion and Atomic Energy of Canada developed the process for manufacturing cobalt-60 at the Chalk River Labs, in Ontario, Canada. A cobalt-59 target was introduced into a research reactor where the cobalt-59 atom absorbed one neutron to become cobalt-60. Once the cobalt-60 material was removed from the research reactor it was encapsulated in stainless steel and seal welded using a Tungsten Inert Gas weld. The first cobalt-60 sources manufactured using material from the Chalk River Labs were used in cancer

  10. Complications of cobalt plaque therapy of choroidal malanomas

    International Nuclear Information System (INIS)

    Char, D.H.; Lonn, L.I.; Margolis, L.W.

    1977-01-01

    We treated a small series of patients with choroidal melanomas with radioactive cobalt plaques. To assess the effectiveness of radiation, we performed radioactive phosphorus ( 32 P) uptake determinations before and after treatment. The 32 P results did not tumor destruction. In five of seven patients with posterior pole melanomas, radiation retinopathy developed after treatment with resultant decrease in vision

  11. Cobalt 60 availability for radiation processing

    International Nuclear Information System (INIS)

    Fraser, F.M.

    1986-01-01

    In the last 20 years, the steady and significant growth in the application of radiation processing to industrial sterilization has been seen. The principal application of this technology is the sterilization of disposable medical products, food irradiation, the irradiation of personal care goods and so on. At present, more than 70 million curies of cobalt-60 supplied by Atomic Energy of Canada Ltd. have been used for gamma processing in these applications. This is estimated to be more than 80 % of the total cobalt-60 in service in the world. Commercial food irradiation has an exciting future, and as to the impact of food irradiation on the availability of cobalt-60 over the next ten years, two principal factors must be examined, namely, the anticipated demand for cobalt-60 in all radiation processing applications, and the supply of cobalt-60 to reliably meet the expected demand. As for the cobalt-60 in service today, 90 % is used for the sterilization of disposable medical products, 5 % for food irradiation, and 5 % for other application. The demand for up to 30 million curies of cobalt-60 is expected over the next 10 years. Today, it is estimated that over 150,000 tons of spices, fruit and fish are irradiated. The potential cobalt-60 production could exceed 110 million curies per year. Gamma processing application will demand nearly 50 million curies in 1990. (Kako, I.)

  12. Cobalt-60 production in CANDU reactors

    International Nuclear Information System (INIS)

    Ross, Michel; Lemire, Christian

    2002-01-01

    CANDU reactors can produce cobalt-60 very efficiently and with an interesting return on investment. This paper discusses what is needed to convert a CANDU reactor into a cobalt-60 producer: what are the different phases, the safety studies required, the physical modifications needed, and what is the minimum involvement of the utility owning the plant. The past ten years of experience of Hydro-Quebec as a cobalt-60 producer will be reviewed, including the management of the risk of both incident and electricity generation loss, and including the benefits for the utility and its personnel. Originally a simple metal used for centuries as a pigment, cobalt-59 today is transformed into cobalt-60, a radioactive element of unprecedented value. Well known in medicine for cancer treatment, cobalt-60 is also used to sterilize a wide range of disposable medical products used in hospitals and to sanitize pharmaceutical and cosmetic products. Cobalt-60 is proving to be a new and effective solution, in the food sector, for preserving harvests and controlling food-borne diseases, or to advantageously replace certain gases and chemical products which are suspected of being harmful or carcinogenic. There are also other applications, such as: hardening of some plastics, treatment of sewage sludge and elimination of harmful insect populations. With a half-life of 5,3 years, cobalt-60 is a metal not found in nature. It is a radioactive isotope produced by exposing stable nuclei of cobalt-59 to neutrons. One of the best places to find such an important neutron source is a nuclear reactor. High energy gamma rays are then emitted during the process of radioactive decay, where cobalt-60 seeks again its stable state

  13. Uveal melanoma: episcleral plaque radiotherapy. First Brazilian experience

    International Nuclear Information System (INIS)

    Erwenne, Clelia Maria; Freitas, Maria Alice Fernandes da Costa; Palazzi, Maristela Amaral; Pacheco, Jose Carlos Gouvea; Salvajoli, Joao Victor; Novaes, Paulo Eduardo; Trippe, Nivaldo; Pereira, Adelino Jose

    1994-01-01

    This paper describes the evolution of ten uveal melanoma carries who have been treated by cobalt-60 episcleral plaques since December, 1998 in A.C. Camargo Hospital, Antonio Prudente Foundation, Sao Paulo. The size of the lesions ranged from four to 11 mm in height and from 11 to 16 mm is the tumor base. The radiation doses applied ranged from 8.000 to 10.000 c Gy in the tumor apex and from 24.000 to 39.000 c Gy in the tumor base. A tumor reduction was observed in nine (90%) patients; in six (60%) the height and the base diameter reduced simultaneously; in three (30%) only the height reduced and in one (10%) the tumor dimensions became the same seven months after therapy. The follow-up of these cases ranged from four to 27 months. The authors discussed the indications, methods, visual results and observed complications of this kind of therapy. (author)

  14. Quality assurance and accuracy in Co-60 radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Scarlat, F; Rebigan, F

    1995-12-01

    The characteristics of a set of 88 Co-60 sources ONCOBALT, are described. This set of radioactive sources is an original choice of a variety of cobalt sources in point of physical size and activity. It includes 5 activity groups of cells (stainless steel) among 2 and 12 mCi, 5 and 15 mm active length and 2, 2.5 and 3 mm external diameter, 4 activity groups of needle activities between 1.3 and 3.4 mCi, 15 and 20 mm active length, 1.8 mm external diameter. By an appropriate choice of activities, dimensions and geometry of irradiation we can get an error of max.5% as to the receive dose. The radioactive purity of cobalt is 99.9%. To meet the requirements in practical radiotherapy we checked the Co-60 sources by tests: tight test, mechanical test, corrosion test and contamination test that gave us full satisfaction.

  15. Dosimetry of normal and wedge fields for a cobalt-60 teletherapy unit

    International Nuclear Information System (INIS)

    Tripathi, U.B.; Kelkar, N.Y.

    1980-01-01

    A simple analytical method for computation of dose distributions for normal and wedge fields is described and the use of the method in planning radiation treatment is outlined. Formulas has been given to compute: (1) depth dose along central axis of cobalt-60 beam, (2) dose to off-axis points, and (3) dose distribution for a wedge field. Good agreement has been found between theoretical and experimental values. With the help of these formulae, the dose at any point can be easily and accurately calculated and radiotherapy can be planned for tumours of very odd shape and sizes. The limitation of the method is that the formulae have been derived for 50% field definition. For cobalt-60 machine having any other field definition, appropriate correction factors have to be applied. (M.G.B.)

  16. Cobalt-60 production in CANDU power reactors

    International Nuclear Information System (INIS)

    Malkoske, G.R.; Norton, J.L.; Slack, J.

    2002-01-01

    MDS Nordion has been supplying cobalt-60 sources to industry for industrial and medical purposes since 1946. These cobalt-60 sources are used in many market and product segments, but are primarily used to sterilize single-use medical products including; surgical kits, gloves, gowns, drapes, and cotton swabs. Other applications include sanitization of cosmetics, microbial reduction of pharmaceutical raw materials, and food irradiation. The technology for producing the cobalt-60 isotope was developed by MDS Nordion and Atomic Energy of Canada Limited (AECL) almost 55 years ago using research reactors at the AECL Chalk River Laboratories in Ontario, Canada. The first cobalt-60 source produced for medical applications was manufactured by MDS Nordion and used in cancer therapy. The benefits of cobalt-60 as applied to medical product manufacturing, were quickly realized and the demand for this radioisotope quickly grew. The same technology for producing cobalt-60 in research reactors was then designed and packaged such that it could be conveniently transferred to a utility/power reactor. In the early 1970's, in co-operation with Ontario Power Generation (formerly Ontario Hydro), bulk cobalt-60 production for industrial irradiation applications was initiated in the four Pickering A CANDU reactors. As the demand and acceptance of sterilization of medical products grew, MDS Nordion expanded its bulk supply by installing the proprietary Canadian technology for producing cobalt-60 in additional CANDU reactors. CANDU is unique among the power reactors of the world, being heavy water moderated and fuelled with natural uranium. They are also designed and supplied with stainless steel adjusters, the primary function of which is to shape the neutron flux to optimize reactor power and fuel bum-up, and to provide excess reactivity needed to overcome xenon-135 poisoning following a reduction of power. The reactor is designed to develop full power output with all of the adjuster

  17. An elevator for cobalt-60 source

    International Nuclear Information System (INIS)

    Tang Zaimin; Liang Donghu

    1990-07-01

    The elevator used for cobalt-60 source is a key device in the irradiation industry. It plays an important role in the safety and control of irradiation operation as well as the utilization rate of radiation source. From 1983 to 1986, Beijing Institute of Nuclear Engineering undertook designing of various size irradiation projects for different uses. Since then a kind of cobalt-60 source elevator suited for the irradiator of wet-source-storage has been chosen. It is reliable in the operation and complete in the function. An automatic control circuit brings the systems of cobalt-60 source elevator into an interlock system which ensures the irradiation operation safety. Besides introducing the structural features and performance of this elevator, the conditions of safety interlocking in raising or lowering the cobalt-60 source is also discussed. The discussion is from the safety viewpoint of operating an irradiator and irradiation technology

  18. Dosimetric intercomparison in Cobalt 60 unities using TLD-100 crystals and CaSO{sub 4}: Dy + Ptfe; Intercomparacion dosimetrica en unidades de cobalto 60 usando cristales de TLD-100 y CaSO{sub 4}: Dy + PTFE

    Energy Technology Data Exchange (ETDEWEB)

    Gaona, E. [Universidad Autonoma Metropolitana Xochimilco, Mexico D.F. (Mexico); Azorin N, J. [Universidad Autonoma Metropolitana Iztapalapa, Mexico D.F. (Mexico); Perez P, M.A. [Instituto Nacional de Cancerologia, Mexico D.F. (Mexico); Castillo H, M. [Centro Medico Nacional 20 de Noviembre, ISSSTE, Mexico D.F. (Mexico); Flores F, F. [Unidad de Oncologia, Centro Medico Nacional, IMSS, Mexico D.F. (Mexico); Guzman R, L.V. [Unidad de Oncologia, Hospital General de Mexico, Mexico D.F. (Mexico)

    1999-07-01

    The purpose of this work is to design and construct a phantom in basis of thermoplastic polymer of methyl methacrylate that is reutilizable and which allows to do an analysis of the absorbed doses in thermoluminescent crystals (Tl) exposed to cobalt 60 to establish the dosimetric intercomparison in cobalt units which allows to do the follow-up of the Quality assurance programs, standardization of calibration procedures, dosimetry and TLD post intercomparison in radiotherapy. This work allows also prove new thermoluminescent materials of national manufacture developed by Juan Azorin and collaborators as the CaSO{sub 4}: Dy + Ptfe. This is a first study which is realized in Mexico with the system crystal-phantom for aims to intercomparison in cobalt 60 units. In this work participate eight unities of cobalt 60 of different trades belonging at four radiotherapy centers. The results of the dose intercomparison of the eight unities of cobalt 60 were in the range 0.95-1.13, taking in account that the values between 0.95 and 1.05 were considered acceptable in terms of the requirements by the standing legislation. (Author)

  19. Transport of cobalt-60 industrial radiation sources

    Science.gov (United States)

    Kunstadt, Peter; Gibson, Wayne

    This paper will deal with safety aspects of the handling of Cobalt-60, the most widely used industrial radio-isotope. Cobalt-60 is a man-made radioisotope of Cobalt-59, a naturally occurring non radioactive element, that is made to order for radiation therapy and a wide range of industrial processing applications including sterilization of medical disposables, food irradiation, etc.

  20. Evaluation of cobalt-60 energy deposit in mouse and monkey using Monte Carlo simulation

    Energy Technology Data Exchange (ETDEWEB)

    Woo, Sang Keun; Kim, Wook; Park, Yong Sung; Kang, Joo Hyun; Lee, Yong Jin [Korea Institute of Radiological and Medical Sciences, KIRAMS, Seoul (Korea, Republic of); Cho, Doo Wan; Lee, Hong Soo; Han, Su Cheol [Jeonbuk Department of Inhalation Research, Korea Institute of toxicology, KRICT, Jeongeup (Korea, Republic of)

    2016-12-15

    These absorbed dose can calculated using the Monte Carlo transport code MCNP (Monte Carlo N-particle transport code). Internal radiotherapy absorbed dose was calculated using conventional software, such as OLINDA/EXM or Monte Carlo simulation. However, the OLINDA/EXM does not calculate individual absorbed dose and non-standard organ, such as tumor. While the Monte Carlo simulation can calculated non-standard organ and specific absorbed dose using individual CT image. External radiotherapy, absorbed dose can calculated by specific absorbed energy in specific organs using Monte Carlo simulation. The specific absorbed energy in each organ was difference between species or even if the same species. Since they have difference organ sizes, position, and density of organs. The aim of this study was to individually evaluated cobalt-60 energy deposit in mouse and monkey using Monte Carlo simulation. We evaluation of cobalt-60 energy deposit in mouse and monkey using Monte Carlo simulation. The absorbed energy in each organ compared with mouse heart was 54.6 fold higher than monkey absorbed energy in heart. Likewise lung was 88.4, liver was 16.0, urinary bladder was 29.4 fold higher than monkey. It means that the distance of each organs and organ mass was effects of the absorbed energy. This result may help to can calculated absorbed dose and more accuracy plan for external radiation beam therapy and internal radiotherapy.

  1. Evaluation of cobalt-60 energy deposit in mouse and monkey using Monte Carlo simulation

    International Nuclear Information System (INIS)

    Woo, Sang Keun; Kim, Wook; Park, Yong Sung; Kang, Joo Hyun; Lee, Yong Jin; Cho, Doo Wan; Lee, Hong Soo; Han, Su Cheol

    2016-01-01

    These absorbed dose can calculated using the Monte Carlo transport code MCNP (Monte Carlo N-particle transport code). Internal radiotherapy absorbed dose was calculated using conventional software, such as OLINDA/EXM or Monte Carlo simulation. However, the OLINDA/EXM does not calculate individual absorbed dose and non-standard organ, such as tumor. While the Monte Carlo simulation can calculated non-standard organ and specific absorbed dose using individual CT image. External radiotherapy, absorbed dose can calculated by specific absorbed energy in specific organs using Monte Carlo simulation. The specific absorbed energy in each organ was difference between species or even if the same species. Since they have difference organ sizes, position, and density of organs. The aim of this study was to individually evaluated cobalt-60 energy deposit in mouse and monkey using Monte Carlo simulation. We evaluation of cobalt-60 energy deposit in mouse and monkey using Monte Carlo simulation. The absorbed energy in each organ compared with mouse heart was 54.6 fold higher than monkey absorbed energy in heart. Likewise lung was 88.4, liver was 16.0, urinary bladder was 29.4 fold higher than monkey. It means that the distance of each organs and organ mass was effects of the absorbed energy. This result may help to can calculated absorbed dose and more accuracy plan for external radiation beam therapy and internal radiotherapy.

  2. The cobalt-60 container scanner

    International Nuclear Information System (INIS)

    Jigang, A.; Liye, Z.; Yisi, L.; Haifeng, W.; Zhifang, W.; Liqiang, W.; Yuanshi, Z.; Xincheng, X.; Furong, L.; Baozeng, G.; Chunfa, S.

    1997-01-01

    The Institute of Nuclear Energy Technology (INET) has successfully designed and constructed a container (cargo) scanner, which uses cobalt-60 of 100-300 Ci as radiation source. The following performances of the Cobalt-60 container scanner have been achieved at INET: a) IQI (Image Quality Indicator) - 2.5% behind 100 mm of steel; b) CI (Contrast Indicator) - 0.7% behind 100 mm of steel; c) SP (Steel Penetration) - 240 mm of steel; d) Maximum Dose per Scanning - 0.02mGy; e) Throughput - twenty 40-foot containers per hour. These performances are equal or similar to those of the accelerator scanners. Besides these nice enough inspection properties, the Cobalt-60 scanner possesses many other special features which are better than accelerator scanners: a) cheap price - it will be only or two tenths of the accelerator scanner's; b) low radiation intensity - the radiation protection problem is much easier to solve and a lot of money can be saved on the radiation shielding building; c) much smaller area for installation and operation; d) simple operation and convenient maintenance; e) high reliability and stability. The Cobalt-60 container (or cargo) scanner is satisfied for boundary customs, seaports, airports and railway stations etc. Because of the nice special features said above, it is more suitable to be applied widely. Its high properties and low price will make it have much better application prospects

  3. Introduction of beam flatness filter for 60Co teletherapy beam and its efficacy in clinical radiotherapy

    International Nuclear Information System (INIS)

    Sathiyan, S.; Ravichandran, R.; Ravikumar, M.

    2003-01-01

    In the western countries cobalt-60 machines have become obsolete, whereas in India we have about 250 machines operational for clinical radiotherapy. The basic differences of 6 MV x-ray beam and cobalt-60 beam are: a) build-up d max point, b) flatness of beam at depths, and c) sharpness of the beam edge. We looked at the homogeneity of delivered dose in the target volume in a 3 field SAD technique for 60 Co (80 cm, 100 cm) and 6 MV treatments. More dose variations are seen in 60 Co treated volume. The excess curvature of isodose curves of 60 Co at depths may be one of the reasons for this inhomogeneity in dose to target volume. Therefore, there is need for achieving perfect flatness in the isodose curves at desired depths. A flattening filter was fabricated using dental wax impression material to account for depths of curvature of 50% 60 Co isodose curve. The filter was fabricated for the Theratron 780C machine for necessary flatness. The beam flatness with filter was measured with a) ionization and b) TL dosimetry methods. The flattened beam profile was compared with 6 MV x-ray beam (Clinac-1800, M/s Varian, USA). Our measurements show uniform flatness of cobalt-60 isodose curve at desired depth and useful radiation field width comparable to 6 MV x-ray photon profile at full width at half maximum (FWHM). If this concept is extendable to short field widths, it appears that there is scope for use of such filter in the treatments of oesophagus, larynx, and pituitary tumours to achieve dose homogeneity. Using this flatness filter and penumbra trimmer, we may achieve better quality cobalt-60 beam for radiotherapy. (author)

  4. Radiological shielding of cobalt-60 teletherapy facility at Komfo Anokye Teaching Hospital, Kumasi, Ghana

    International Nuclear Information System (INIS)

    Addison, E.K.T.; Kitcher, H.W.; Kyere, A.W.K.; Nani, E.K.

    2003-01-01

    The radiological shielding of the radiotherapy unit, oncology directorate, Komfo Anokye teaching hospital, has been assessed based on the workload and occupancy factors, in addition to the technical and performance specification of the cirus cobalt-60 equipment. Aspects relating to the design of treatment room were described. Calculations were based on NCRP report 49 and measurements were carried out on the structural shielding design of the cobalt-60 unit by the standard method prescribed in the NCRP report 49. This study was carried out to evaluate the adequacy of the shielding put in place to ensure the safety of the staff, public and oncological patients. The results obtained and measurements made, all fall below the regulatory effective dose limit of 20 mSv per year for staff and 1 mSv per year for the public (author)

  5. SU-E-J-198: Out-Of-Field Dose and Surface Dose Measurements of MRI-Guided Cobalt-60 Radiotherapy

    International Nuclear Information System (INIS)

    Lamb, J; Agazaryan, N; Cao, M; Low, D; Thomas, D; Yang, Y

    2015-01-01

    Purpose: To measure quantities of dosimetric interest in an MRI-guided cobalt radiotherapy machine that was recently introduced to clinical use. Methods: Out-of-field dose due to photon scatter and leakage was measured using an ion chamber and solid water slabs mimicking a human body. Surface dose was measured by irradiating stacks of radiochromic film and extrapolating to zero thickness. Electron out-of-field dose was characterized using solid water slabs and radiochromic film. Results: For some phantom geometries, up to 50% of Dmax was observed up to 10 cm laterally from the edge of the beam. The maximum penetration was between 1 and 2 mm in solid water, indicating an electron energy not greater than approximately 0.4 MeV. Out-of-field dose from photon scatter measured at 1 cm depth in solid water was found to fall to less than 10% of Dmax at a distance of 1.2 cm from the edge of a 10.5 × 10.5 cm field, and less that 1% of Dmax at a distance of 10 cm from field edge. Surface dose was measured to be 8% of Dmax. Conclusion: Surface dose and out-of-field dose from the MRIguided cobalt radiotherapy machine was measured and found to be within acceptable limits. Electron out-of-field dose, an effect unique to MRI-guided radiotherapy and presumed to arise from low-energy electrons trapped by the Lorentz force, was quantified. Dr. Low is a member of the scientific advisory board of ViewRay, Inc

  6. Total quality management of cobalt-60 sources

    International Nuclear Information System (INIS)

    Malkoske, G.R.

    1999-01-01

    Total Quality Management of Cobalt-60 sources by a supplier requires a life cycle approach to source management. This covers various aspects, including design, manufacturing, installation, field inspection, source surveillance and return of cobalt-60 sources at the end of their useful life. The Total Quality Management approach demonstrates a strong industry commitment to the beneficial use of gamma technology for industrial irradiation applications in both developed nations and in those nations who are developing their infrastructure and techniques for the beneficial use of this technology. MDS Nordion continues to demonstrate its support and commitment to the industry by developing and implementing state-of-the-art standards for the safe use of cobalt-60 sources

  7. Treatment of non-resectable malignant iris tumours with custom designed plaque radiotherapy

    International Nuclear Information System (INIS)

    Shields, C.L.; Shields, J.A.; Potter, P. De; Singh, A.D.; Hernandez, C.; Brady, L.W.

    1995-01-01

    Background- Plaque radiotherapy is the most common method of managing posterior uveal melanoma but its use for iris melanoma and iris metastases has not yet been evaluated. Methods -Fourteen patients with non-resectable iris melanoma and four with iris metastasis were treated with plaque radiotherapy. The tumour response to treatment and the local side effects of the radioactive plaque were evaluated. Results -In the iris melanoma group over a mean follow up of 26 (range 6-75) months, the tumour regressed in 13 of the 14 patients (93%) and recurred as diffuse seeding in one patient (7%). Despite large doses of radiation given transcorneally, the cornea developed epitheliopathy, abraxion, and oedema in only one case each. The major radiation side effects were localised iris vasculopathy without glaucoma in two cases, posterior synechiae in five cases, and cataract in six cases. In the iris metastasis group, tumour regression was observed in all four patients (100%) and radiation side effects were not evident over the relatively short mean follow up period of 8 (range 4-9) months. All of the 14 patients with irradiated iris melanoma have remained systemically healthy without metastasis while three of the four patients with irradiated iris metastases have died of metastases from the primary neoplasm. Conclusion - Custom designed plaque radiotherapy appears to be an effective alternative method of controlling non-resectable diffuse iris melanoma and solitary iris metastasis and has relatively few side effects. (author)

  8. Palladium-103 plaque radiotherapy for choroidal melanoma: an 11-year study

    International Nuclear Information System (INIS)

    Finger, Paul T.; Berson, Anthony; Ng, Tracy; Szechter, Andrzej

    2002-01-01

    Purpose: To describe 11 years of experience with 103 Pd ophthalmic plaque brachytherapy for intraocular melanoma. Methods and Materials: Since 1990, 152 patients have been diagnosed with uveal melanoma, found to be negative for metastatic disease, and treated with 103 Pd radioactive plaque radiotherapy. This study presents the first 100 patients treated with 103 Pd and followed for ≥2 years. Plaques were sewn to the episclera to cover the base of the intraocular tumor. Treatment involved delivery of a mean apical radiation dose of 80.5 Gy during 5-7 days' continuous treatment. Patients were evaluated for local tumor control, visual acuity, radiation damage (retinopathy, optic neuropathy, cataract), and metastatic disease. Results: Patients in this series were followed for a mean of 4.6 years (55.4 months). 103 Pd seeds were found to be equivalent to 125 I with respect to plaque manufacture and ease of dosimetric calculations. We noted a local control rate of 96% and six secondary enucleations. Including the enucleated patients, the visual acuity evaluations revealed that 35% lost six or more lines of vision and 73% had vision of 20/200 or better. Conclusion: Long-term results now exist describing the use of 103 Pd plaque radiotherapy for uveal (iris, ciliary body, and choroidal) melanoma. Compared with the results from centers using 125 I, patients in this series experienced equivalent local control rates and better visual function

  9. PENYERAPAN COBALT-60 DARI AIR OLEH TANAMAN KIAPU (Pistia stratiotes L.)

    OpenAIRE

    Lailatul Nuzzulul Safitri; Poppy Intan Tjahaja; Ida Bagus Made Suryatika

    2015-01-01

    Has conducted research Cobalt-60 radionuclide uptake by plants kiapu (Pistia stratiotes L.) found in many waters. The purpose of the study was to determine the value of the transfer factor on plant kiapu to Cobalt-60 in water. The study was conducted by growing plants on media kiapu gutter water in pots with the height 35 cm and diameter 11,5 cm containing Cobalt-60. The amount of Cobalt - 60 is absorbed and accumulated by the plant parts, i.e. roots and leaves, was observed by measuring the ...

  10. Preliminary dosimetric methodology for a new cobalt-60 irradiator for radioinduced necrosis

    International Nuclear Information System (INIS)

    Moura, Eduardo S.; Mosca, Rodrigo C.; Zeituni, Carlos A.; Rostelato, Maria Elisa C.M.; Mathor, Monica B.; Sakuraba, Roberto K.; Goncalves, Vinicius D.

    2011-01-01

    The use of ionizing radiation in medical procedures, as radiotherapy, is a well-established clinical process and it has been used for several decades with good clinical results and continuous technology development for treatment optimization. On the contrary, some injuries such as necrosis, may occur with patients, due to wrong administration of the absorbed dose or with expected side effects. To evaluate how these injuries could be investigated and how they can be treated, a new Cobalto-60 irradiator was developed to induce radionecrosis in mice. This irradiator is composed by a cylindrical size and it was set up with eleven Cobalt-60 sources aligned in the surface of a cylindrical lead. This alignment guarantees a small dose focal area in a longitudinal table, with proper frames for positioning mice precisely during the irradiations period. The dosimetric procedure will measure the absorbed dose in the dose focal area, delimited the area of irradiation with penumbra regions (gradients absorbed dose profiles) and others anatomical regions of the mice with high radiosensitivity. Possible dosimetric procedures and related devices will be present in this work,. The obtained dosimetric data will be applied to ensure the accurate period of radiation of a given position. This preliminary study assures that the fundamental dosimetric process of this new Cobalt-60 irradiator and it predicates that dosimetric processes area feasible to be conducted. (author)

  11. Preliminary dosimetric methodology for a new cobalt-60 irradiator for radioinduced necrosis

    Energy Technology Data Exchange (ETDEWEB)

    Moura, Eduardo S.; Mosca, Rodrigo C.; Zeituni, Carlos A.; Rostelato, Maria Elisa C.M.; Mathor, Monica B., E-mail: esmoura@ipen.b [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil); Sakuraba, Roberto K.; Goncalves, Vinicius D. [Hospital Israelita Albert Einstein (HIAE), Sao Paulo, SP (Brazil)

    2011-07-01

    The use of ionizing radiation in medical procedures, as radiotherapy, is a well-established clinical process and it has been used for several decades with good clinical results and continuous technology development for treatment optimization. On the contrary, some injuries such as necrosis, may occur with patients, due to wrong administration of the absorbed dose or with expected side effects. To evaluate how these injuries could be investigated and how they can be treated, a new Cobalto-60 irradiator was developed to induce radionecrosis in mice. This irradiator is composed by a cylindrical size and it was set up with eleven Cobalt-60 sources aligned in the surface of a cylindrical lead. This alignment guarantees a small dose focal area in a longitudinal table, with proper frames for positioning mice precisely during the irradiations period. The dosimetric procedure will measure the absorbed dose in the dose focal area, delimited the area of irradiation with penumbra regions (gradients absorbed dose profiles) and others anatomical regions of the mice with high radiosensitivity. Possible dosimetric procedures and related devices will be present in this work,. The obtained dosimetric data will be applied to ensure the accurate period of radiation of a given position. This preliminary study assures that the fundamental dosimetric process of this new Cobalt-60 irradiator and it predicates that dosimetric processes area feasible to be conducted. (author)

  12. Cobalt-60 control in Ontario Hydro reactors

    International Nuclear Information System (INIS)

    Lacy, C.S.

    1988-01-01

    This paper discusses the impact of specifying reduced Cobalt-59 in the primary heat transport circuit materials of construction on the radiation fields developed around the primary circuit. An eight-fold reduction in steam generator radiation fields due to Cobalt-60 has been observed for two identical sets of reactors, one with and one without Cobalt-59 control. The comparison is between eight reactors at the Pickering Nuclear Generating Station (PNGS). Units 5 to 8 (PNGS-B) are identical to Units 1 to 4 (PNGS-A) except that PNGS-B has reduced impurity Cobalt-59 in the alloys of construction and a reduced use of stellite. The effects of chemistry control are also discussed

  13. A laboratory and field evaluation of the mobility of cobalt-60/EDTA

    International Nuclear Information System (INIS)

    Jones, T.L.; Gee, G.W.; Kirkham, R.R.; Swanson, J.L.

    1983-01-01

    We have observed a time and soil type dependence in the ability of the organic complexant EDTA to keep cobalt-60 in solution. Test results indicate that short-term adsorption tests lasting 5 days or less can be misleading. In short-term tests using cobalt-60/EDTA and soil from the Hanford site, low sorption in batch tests and high mobility in column tests were observed. During long-term batch test using cobalt-60/EDTA, the percentage of cobalt remaining in solution decreased from 90% after 7 days to less than 10% after 500 days. In laboratory and field column tests where low water flow rates allowed long contact time, virtually no cobalt movement was observed even though in the field test tritium was transported over 4 meters. Long-term batch tests using cobalt-60/EDTA and soil from Savannah River burial grounds showed that cobalt remainin in solution dropped to 30% of the total cobalt added after 5 days and to less than 1% after 15 days. Batch tests using soil from Oak Ridge burial grounds were less dramatic showing cobalt in solution decreasing from 90% after 5 days to 70% after 35 days. The cobalt-60/EDTA complex appears to be dissociating and leaving uncomplexed cobalt which is readily sorbed. The dissociation seems to be rather complete in Hanford and Savannah River soil but limited in the Oak Ridge soil. The implication to waste management is that the potential for transport of cobalt by EDTA may not be as serious at all burial sites as once thought

  14. C-188 cobalt-60 sealed source integrity: source monitoring

    International Nuclear Information System (INIS)

    Defalco, G.M.; Shah, V.

    1995-01-01

    The integrity of C-188 cobalt-60 sealed sources used for radiation processing will be a key factor in the continued industrial acceptance and growth of gamma irradiation technology. Given the public's relatively poor understanding of most nuclear topics and the news media's tendency to sensationalize events, it is appropriate for suppliers and users of gamma technology to be vigilant and conservative regarding the application of cobalt-60 sources to industrial purposes. Nordion's recent decision to extend the optional warranty on its C-188 cobalt-60 sealed source from 15 years to 20 years is based on over 30 years of data generated from its on-going SOURCE SURVEILLANCE PROGRAM. This paper presents an overview of the C-188 SOURCE SURVEILLANCE PROGRAM. (author)

  15. Cobalt 60 gamma irradiation current status, trends and insights

    International Nuclear Information System (INIS)

    Corley, John T.

    1998-01-01

    This paper discusses the current status, trends and insights into the continued, safe use of cobalt 60 gamma irradiation. Also presented are some of the many initiatives undertaken at MDS Nordion. Topics covered include our investment for the future supply of raw materials and the latest news from source production. Briefly presented are the tasks associated with the safe transport of cobalt 60 around the world. Discussed is cobalt 60 usage at the customer site; more specifically maintaining source integrity, source utilization and irradiator design trends. Highlighted are industry trends for North America, Europe and the rest of the world. Finally presented are the challenges and opportunities for the industry. Stressed in the paper is the need to work together

  16. Studi Standarisasi Radioterapi Cobalt-60 Terhadap Kuantitas Sel Darah Pada Penderita Kanker Serviks (Cancer Cervics Di Rsup Sanglah Denpasar

    Directory of Open Access Journals (Sweden)

    Retianingsih Oeta Ulan

    2017-09-01

    Full Text Available After doing research with Title Study of Cobalt-60 radiotherapy Standards Against Quantity Blood Cells In Patients with Cervical Cancer (Cancer Cervics at Sanglah Hospital in Denpasar. This study uses secondary data such as a complete blood from each patient with cervical cancer in 2015 that radiotherapy with fractionation method. The amount of patient data used in this study is 5 pieces. The quantity of blood cells that are analyzed include RBC, HGB, WBC and WBC Components (LY, EO, EO, BA, NE, MO. Fractionation dose is 800-5800cGy. The results of data analysis showed that each blood cell components are still within the range of 2-50%, so a method of radiotherapy is still fit for use.

  17. Activation of cobalt 60 in the LVR-15 reactor core

    International Nuclear Information System (INIS)

    Melichar, F.

    1995-12-01

    Cobalt disks were irradiated in the LVR-15 reactor and the relevant cobalt-60 production parameters, particularly the formation rate, were measured. The data were compared with those from previous work by other authors and some discrepancies were found. It is concluded that additional experiments have to be performed in order to obtain reliable data, usable in economic balance assessment with respect to the use of hot chambers for the production of sealed cobalt-60 sources. (P.A.). 4 tabs., 3 refs., 10 annexes

  18. Cobalt 60 commercial irradiation facilities

    International Nuclear Information System (INIS)

    West, G.

    1985-01-01

    The advantage of using cobalt 60 for ionizing treatment is that it has excellent penetration. Gamma plants are also very efficient, in as much as there is very little mechanical or electrical equipment in a gamma irradiation facility. The average efficiency of a gamma plant is usually around 95% of all available processing time

  19. An Economic Analysis of Electron Accelerators and Cobalt-60 for Irradiating Food

    OpenAIRE

    Morrison, Rosanna Mentzer

    1989-01-01

    Average costs per pound of irradiating food are similar for the electron accelerator and cobalt-60 irradiators analyzed in this study, but initial investment costs can vary by $1 million. Irradiation costs range from 0.5 to 7 cents per pound and decrease as annual volumes treated increase. Cobalt-60 is less expensive than electron beams for annual volumes below 50 million pounds. For radiation source requirements above the equivalent of 1 million curies of cobalt-60, electron beams are more e...

  20. New avenues in cobalt-60 production at Ontario Hydro

    International Nuclear Information System (INIS)

    Mylvaganam, C.K.; Ronchka, R.A.

    1990-01-01

    Ontario Hydro produces cobalt-60 in the control rods of twelve power reactors. These reactors have a typical flux of 2 x 10 14 neutrons/cm 2 /s, making them efficient producers of cobalt-60. Current annual production is 45 million curies. Since the primary function of these reactors is the production of electricity, their flexibility to meet the needs of commercial cobalt production by the control rod route is limited. Ontario Hydro is therefore developing innovative production techniques, making use of the CANDU reactor's unique ability to be fuelled on-power. These techniques will enable production to better respond to the market's requirements for quantity and specific activity. As it is supplementary to control rod production, annual supply could potentially reach 165 million curies. (author)

  1. Brachytherapy with cobalt plaques in the conservative treatment of intraocular tumors. The Brazilian experience

    International Nuclear Information System (INIS)

    Pellizzon, Antonio Cassio Assis; Trippe, N.; Novaes, P.E.; Ferrigno, R.; Fogarolli, R.C.; Maia, M.A.C.; Salvajoli, J.V.; Baraldi, H.E.; Chojniak, M.M.; Erwene, C.M.

    1996-01-01

    Purpose/Objective: To show the retrospective results of intraocular tumors, including uveal melanomas and retinoblastomas treated by exclusive brachytherapy with cobalt plaques. The goal was to keep the vision function with not compromising the chance of cure. Materials and Methods: From December 1989 to December 1993, 76 cases of intraocular tumors, being 56 adult patients with uveal melanomas and 20 children with retinoblastoma, were treated with exclusive intraocular brachytherapy through cobalt plaques. The prescribed dose was 40 Gy, calculated at the apex of the lesion for retinoblastomas and 100 Gy for melanomas. The selection criteria included those introcular lesions with diameter until 15 mm. Results: With the minimum follow up of 24 months, of the 56 patients with uveal melanomas, 41 (73,3%) had their vision preserved with no evidence of disease, while 15 (26,4%) had local failure and were underwent to enucleation. With the medium follow up of 27 months, of the 20 patients with retinoblastoma, 17 (85,5%) had their vision preserved with no evidence of disease, while 3 (15%) had local failure and were underwent to enucleation. All patients are alive with no evidence of systemic disease. Conclusion: When well indicated, the conservative treatment of intraocular tumors with brachytherapy is a good alternative to enucleation and must be done by a multidisciplinary and well trained medical team

  2. National Low-Level Waste Management Program Radionuclide Report Series: Volume 12, Cobalt-60

    International Nuclear Information System (INIS)

    Adams, J.P.

    1995-06-01

    This report outlines the basic radiological and chemical characteristics of cobalt-60 ( 60 Co) and examines how these characteristics affect the behavior of 60 Co in various environmental media, such as soils, groundwater, plants, animals, the atmosphere, and the human body. Discussions also include methods of 60 Co production, waste types, and waste forms that contain 60 Co. All cobalt atoms contain 27 protons (Z = 27) and various numbers of neutrons (typically N = 27 to 37 neutrons) within the atom's nucleus. There is only one stable isotope of cobalt, namely 59 Co. All other cobalt isotopes, including 60 Co, are radioactive. The radioactive isotopes of cobalt have half-lives ranging from less than a second ( 54 Co-0.19 s) to 5.2 years ( 60 Co). The radioactive isotopes of cobalt are not a normal constituent of the natural environment and are generated as a result of human activities. The primary source of 60 Co in the environment has been low-level radioactive waste material generated as a result of neutron activation of stable 59 Co that is present in the structural components of nuclear reactor vessels. This isotope is also intentionally produced, usually in reactors but also to some degree in accelerators for industrial and medical uses, such as for radiation sources for cancer treatment and nondestructive testing of metals and welds. 60 Co may enter the environment as a result of the activities associated with nuclear reactor operations and decommissioning and when industrial and medical sources are being used, manufactured, or disposed

  3. New formula for calculation of cobalt-60 percent depth dose

    International Nuclear Information System (INIS)

    Tahmasebi Birgani, M. J.; Ghorbani, M.

    2005-01-01

    On the basis of percent depth dose calculation, the application of - dosimetry in radiotherapy has an important role to play in reducing the chance of tumor recurrence. The aim of this study is to introduce a new formula for calculating the central axis percent depth doses of Cobalt-60 beam. Materials and Methods: In the present study, based on the British Journal of Radiology table, nine new formulas are developed and evaluated for depths of 0.5 - 30 cm and fields of (4*4) - (45*45) cm 2 . To evaluate the agreement between the formulas and the table, the average of the absolute differences between the values was used and the formula with the least average was selected as the best fitted formula. The Microsoft Excel 2000 and the Data fit 8.0 soft wares were used to perform the calculations. Results: The results of this study indicated that one amongst the nine formulas gave a better agreement with the percent depth doses listed in the table of British Journal of Radiology . The new formula has two parts in terms of log (A/P). The first part as a linear function with the depth in the range of 0.5 to 5 cm and the other one as a second order polynomial with the depth in the range of 6 to 30 cm. The average of - the differences between the tabulated and the calculated data using the formula (Δ) is equal to 0.3 152. Discussion and Conclusion: Therefore, the calculated percent depth dose data based on this formula has a better agreement with the published data for Cobalt-60 source. This formula could be used to calculate the percent depth dose for the depths and the field sizes not listed in the British Journal of Radiology table

  4. Cobalt Blues The Story of Leonard Grimmett, the Man Behind the First Cobalt-60 Unit in the United States

    CERN Document Server

    Almond, Peter R

    2013-01-01

    For the latter half of the 20th century, cobalt-60 units were the mainstay of radiation treatments for cancer. Cobalt Blues describes the development of the first cobalt-60 unit in the United States and the man behind it, Leonard Grimmett. Conceptually conceived before World War II, it only became possible because of the development of nuclear reactors during the war. Although Grimmett conceived of and published his ideas first, the Canadians built the first units because of the capability of their reactor to produce more suitable cobalt-60 sources. This book tells the story of how Grimmett and others came together at the time that the U S Atomic Energy Agency was pushing the use of radioactivity in medicine. Due to his sudden death, very little information about Grimmett was known until recently, when various documents have come to light, allowing the full story to be told.

  5. National Low-Level Waste Management Program Radionuclide Report Series: Volume 12, Cobalt-60

    Energy Technology Data Exchange (ETDEWEB)

    Adams, J.P.

    1995-06-01

    This report outlines the basic radiological and chemical characteristics of cobalt-60 ({sup 60}Co) and examines how these characteristics affect the behavior of {sup 60}Co in various environmental media, such as soils, groundwater, plants, animals, the atmosphere, and the human body. Discussions also include methods of {sup 60}Co production, waste types, and waste forms that contain {sup 60}Co. All cobalt atoms contain 27 protons (Z = 27) and various numbers of neutrons (typically N = 27 to 37 neutrons) within the atom`s nucleus. There is only one stable isotope of cobalt, namely {sup 59}Co. All other cobalt isotopes, including {sup 60}Co, are radioactive. The radioactive isotopes of cobalt have half-lives ranging from less than a second ({sup 54}Co-0.19 s) to 5.2 years ({sup 60}Co). The radioactive isotopes of cobalt are not a normal constituent of the natural environment and are generated as a result of human activities. The primary source of {sup 60}Co in the environment has been low-level radioactive waste material generated as a result of neutron activation of stable {sup 59}Co that is present in the structural components of nuclear reactor vessels. This isotope is also intentionally produced, usually in reactors but also to some degree in accelerators for industrial and medical uses, such as for radiation sources for cancer treatment and nondestructive testing of metals and welds. {sup 60}Co may enter the environment as a result of the activities associated with nuclear reactor operations and decommissioning and when industrial and medical sources are being used, manufactured, or disposed.

  6. Investigation of the production of cobalt-60 via particle accelerator

    Directory of Open Access Journals (Sweden)

    Artun Ozan

    2017-01-01

    Full Text Available The production process of cobalt-60 was simulated by a particle accelerator in the energy range of 5 to 100 MeV, particle beam current of 1 mA, and irradiation time of 1 hour to perform yield, activity of reaction, and integral yield for charged particle-induced reactions. Based on nuclear reaction processes, the obtained results in the production process of cobalt-60 were also discussed in detail to determine appropriate target material, optimum energy ranges, and suitable reactions.

  7. Design electronic of manual control for cobalt unit Alcyon II of the National Center of Radiotherapy

    International Nuclear Information System (INIS)

    Morraz V, E.; Campos, X.

    2002-01-01

    A manual control for the cobalt unit, of French production, it was designed by the team of electronic of the national center of radiotherapy with materials found in the national trade. The control has the same characteristics that the original one and it is also adapted a switch from which you can control the lights of the room of the cobalt

  8. Ultrasonography-guided cobalt-60 brachytherapy for malignant glioma

    International Nuclear Information System (INIS)

    Sakai, Noboru; Takenaka, Katsunobu; Ueda, Tatsuya

    1989-01-01

    Brachytherapy with cobalt-60 source is reported. In this method it is characterized that the source is inserted interstitially with remote control system by after-loading method via outer catheter (using tandem tube), which was established in the center of residual tumor, using ultrasonography guide with trepanation, or intraoperatively put within the dead space after tumor resection. Six cases of deep-seated and recurrent malignant glioma, were treated with this method. A total dose of 20 to 45 Gy (10 to 15 Gy/day for 2 to 3 days) was delivered to the target. Additionally conventional external irradiation was followed. The effect of cobalt-60 brachytherapy on such tumors were favorable especially for well-circumscribed glioma less than 3 cm on CT scan. (author)

  9. Effects of bathing on skin exposed to Cobalt-60 teletherapy

    International Nuclear Information System (INIS)

    Bohannan, P.A.

    1982-01-01

    The problem of this study was to determine the effects of bathing or not bathing on the degree of skin reaction occurring in patients receiving Cobalt-60 radiation therapy to the chest, back, or head and neck. A quasi experimental study was done using a 2 x 7 repeated measures design. Sixty-seven subjects receiving Cobalt-60 radiation therapy at the Moncrief Radiation Center in Fort Worth, Texas, were randomly assigned to an experimental group who did not bathe during therapy and a control group who did bathe with water during therapy. Observations were made after each 1000 rads of therapy and two weeks after the final treatment. Erythema and pigmentation measurements were taken using the Photovolt 670 and rates were assigned using the Baker-Leith Rating Scale. Findings from the study suggest that bathing the portal of entry with water during the treatment period does not influence the degree of skin response that occurs from Cobalt-60 teletherapy

  10. Nationwide survey of cobalt-60 teletherapy. Final report

    International Nuclear Information System (INIS)

    Thompson, D.L.; Kearly, F.E.; Wyckoff, H.O.; Gitlin, J.N.; Reffit, E.B.; Shangold, E.J.

    1980-08-01

    The Bureau of Radiological Health and the National Bureau of Standards conducted a nationwide survey of cobalt-60 teletherapy facilities to determine their accuracy in delivery of a prescribed dose to a phantom. Participation was obtained from 684 respondents or 75 percent of US facilities. For each cobalt-60 unit the average dose recorded on five dosimeters was within 5 percent of the prescribed value for 83 percent of the respondents and only exceeded a 10 percent difference for 3 percent of the respondents. Sufficient information for reconstruction of dose calculations was available for 87 percent of the participating facilities. Of these reconstructed calculations, 56 percent were within 1 percent of the prescribed dose of 300 rads. The analysis of data from the survey showed that better performance were related to a number of factors. Among these were expressing the machine calibration in terms of dose rate, performing the machine calibration on an annual basis, and correcting for source decay on a monthly basis. Larger facilities achieved better results than smaller facilities when calculating the absorbed dose rate. Also, each 4 machine characteristics (isocentric mounting, short exposure time, high normalized output, and long treatment distance) were related to better performance with regard to both dosimeter readings and calculated doses. Larger facilities were more likely to be using a cobalt-60 unit having those characteristics

  11. Calculation support for industrial production of cobalt-60 at Leningrad NPP

    International Nuclear Information System (INIS)

    Artemov, Vladimir; Elshin, Alexander; Ivanov, Alexander; Gorbunov, Evgeny; Ikonnikov, Roman; Pimenov, Alexander

    2008-01-01

    Cobalt-60 is industrially produced at the Leningrad NPP by irradiation of cobalt-59 in special-purpose facilities loaded into the RBMK reactor core (all 4 units). The paper describes calculation methods used to determine the current activity of cobalt in irradiation assemblies for their timely unloading. The described peculiarities of core calculation model account for continuous refueling, overloading of irradiation assemblies and individual thermohydraulics in each channel under variation of reactor power. Fuel burnup in the core is calculated with a time step of about 24 hours. The resulting values for cobalt activity and uncertainties are presented in the paper as well. Deviation of calculated cobalt activity from measured activity is within the experimental accuracy of 10% (at confidence probability of 0.95). (authors)

  12. An athymic mouse model to mimic cobalt-60 cutaneous radiation injury

    Energy Technology Data Exchange (ETDEWEB)

    Mosca, Rodrigo Crespo; Ferreira, Danilo Cardenuto; Napolitano, Celia Marina; Santin, Stefany Plumeri; Dornelles, Leonardo Dalla Porta; Alvarenga, Eluara Ortigoso; Mathor, Monica Beatriz, E-mail: rcmosca@usp.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2013-07-01

    Propose: Cutaneous wound from irradiation is the most common complication in radiotherapy treatment, and can be lead to mortality. We describe an athymic mouse model to mimic cutaneous radiation injury by Cobalt-60. Methods: A protocol was including dosimetry with silicon diodes,10x10x5 cm arrangement made by four lead bricks and PVC pipe designed to immobilize the athymic mouse in order to irradiate one clamped back skin point that was subdivided in four parts. To get the measurements of dose rates on the arrangement in Panoramic Irradiator, it was used a silicon diode encased in an opaque protection for ambient light and connected to an electric cable, forming a dosing probe. The currents generated in diode sensitive volume as a function of time of exposure to gamma radiation coming from the radiator, with dose rate of 0,015 Gy/min in positions 1, 0,021 Gy/min in position 2, 0,55 Gy/min in position 3 and 1,45 Gy/min in position four. After the dosimetry, each athymic mouse was anesthetized using Xylazine and Ketamine dilution and entered into a PVC pipe and a small portion of skin (1 cm{sup 3}) was clamped. This tube was then fixed to arrangement and the athymic mouse was irradiate for 60 min, than it was being returned to its cage. Results: The wound was visualized in all animals and photographed after 5 days of irradiation, with the emergence of ulceration after 9 days. No systemic or lethal sequelae occurred or visualized in any animals. Late clinical signs included a wound healing after 22 days. Conclusion: While still being a baseline study, we created a new functional preclinical animal model that can be used for new therapies and may improve radiotherapy management. (author)

  13. An athymic mouse model to mimic cobalt-60 cutaneous radiation injury

    International Nuclear Information System (INIS)

    Mosca, Rodrigo Crespo; Ferreira, Danilo Cardenuto; Napolitano, Celia Marina; Santin, Stefany Plumeri; Dornelles, Leonardo Dalla Porta; Alvarenga, Eluara Ortigoso; Mathor, Monica Beatriz

    2013-01-01

    Propose: Cutaneous wound from irradiation is the most common complication in radiotherapy treatment, and can be lead to mortality. We describe an athymic mouse model to mimic cutaneous radiation injury by Cobalt-60. Methods: A protocol was including dosimetry with silicon diodes,10x10x5 cm arrangement made by four lead bricks and PVC pipe designed to immobilize the athymic mouse in order to irradiate one clamped back skin point that was subdivided in four parts. To get the measurements of dose rates on the arrangement in Panoramic Irradiator, it was used a silicon diode encased in an opaque protection for ambient light and connected to an electric cable, forming a dosing probe. The currents generated in diode sensitive volume as a function of time of exposure to gamma radiation coming from the radiator, with dose rate of 0,015 Gy/min in positions 1, 0,021 Gy/min in position 2, 0,55 Gy/min in position 3 and 1,45 Gy/min in position four. After the dosimetry, each athymic mouse was anesthetized using Xylazine and Ketamine dilution and entered into a PVC pipe and a small portion of skin (1 cm 3 ) was clamped. This tube was then fixed to arrangement and the athymic mouse was irradiate for 60 min, than it was being returned to its cage. Results: The wound was visualized in all animals and photographed after 5 days of irradiation, with the emergence of ulceration after 9 days. No systemic or lethal sequelae occurred or visualized in any animals. Late clinical signs included a wound healing after 22 days. Conclusion: While still being a baseline study, we created a new functional preclinical animal model that can be used for new therapies and may improve radiotherapy management. (author)

  14. SU-F-T-530: Characterization of a 60-Leaf Motorized MLC Designed for Cobalt-60 Units

    International Nuclear Information System (INIS)

    Xu, L; Smith, L; Ciresianu, A

    2016-01-01

    Purpose: In a continuing effort to improve conformal radiation therapy with Cobalt-60 units, a 60-leaf MLC was designed, manufactured, and released to market. This work describes the physics measurements taken to characterize the clinical performance of this MLC. Methods: A 60 leaf MLC was custom designed with tungsten leaves of 4.5 cm height, single focused, achieving field size of 30×30 cm^2 when mounted on a 100cm SAD Cobalt-60 unit. Leakage and output factor measurements were performed using a single ion chamber in a solid water phantom. Penumbra and surface dose were measured using scanning chambers and diodes in a water phantom. Radiation-light coincidence measurements were performed using radiographic films. Results: With MLC mounted, measured penumbras at all depths are smaller than with jaws only. Surface doses were not significantly affected by the presence of MLC, and remained below values recommended by regulatory bodies. Light-radiation coincidences were found to be better than 3 mm for all field sizes. Leakage through the MLC was found to be strongly dependent on field size, increasing from 1.0 % for a 10×10 cm field to 2.0% for a 30×30 cm field. Such results meet the requirements of IEC 60601-2-11. The MLC was found to have significant influence on the output factor, when field size defined by MLC is significantly smaller than field size defined by jaws. Such effect is also observed on linear accelerators, but it is more pronounced on Cobalt-60 units. A 10×10 “diamond” MLC shape inside a 14×14 cm jaw showed output factor that is 5.7% higher than 10×10 cm field defined by matching MLC and jaws. Conclusion: The MLC offers clinically acceptable performance in penumbra, surface dose, and light-radiation coincidence. Several units of this MLC have recently been installed and used clinically. Validation of Cobalt-60 based IMRT with this MLC is ongoing. The authors are employees of Best Theratrnics Ltd.

  15. SU-F-T-530: Characterization of a 60-Leaf Motorized MLC Designed for Cobalt-60 Units

    Energy Technology Data Exchange (ETDEWEB)

    Xu, L; Smith, L; Ciresianu, A [Best Theratronics, Ottawa, ON (Canada)

    2016-06-15

    Purpose: In a continuing effort to improve conformal radiation therapy with Cobalt-60 units, a 60-leaf MLC was designed, manufactured, and released to market. This work describes the physics measurements taken to characterize the clinical performance of this MLC. Methods: A 60 leaf MLC was custom designed with tungsten leaves of 4.5 cm height, single focused, achieving field size of 30×30 cm^2 when mounted on a 100cm SAD Cobalt-60 unit. Leakage and output factor measurements were performed using a single ion chamber in a solid water phantom. Penumbra and surface dose were measured using scanning chambers and diodes in a water phantom. Radiation-light coincidence measurements were performed using radiographic films. Results: With MLC mounted, measured penumbras at all depths are smaller than with jaws only. Surface doses were not significantly affected by the presence of MLC, and remained below values recommended by regulatory bodies. Light-radiation coincidences were found to be better than 3 mm for all field sizes. Leakage through the MLC was found to be strongly dependent on field size, increasing from 1.0 % for a 10×10 cm field to 2.0% for a 30×30 cm field. Such results meet the requirements of IEC 60601-2-11. The MLC was found to have significant influence on the output factor, when field size defined by MLC is significantly smaller than field size defined by jaws. Such effect is also observed on linear accelerators, but it is more pronounced on Cobalt-60 units. A 10×10 “diamond” MLC shape inside a 14×14 cm jaw showed output factor that is 5.7% higher than 10×10 cm field defined by matching MLC and jaws. Conclusion: The MLC offers clinically acceptable performance in penumbra, surface dose, and light-radiation coincidence. Several units of this MLC have recently been installed and used clinically. Validation of Cobalt-60 based IMRT with this MLC is ongoing. The authors are employees of Best Theratrnics Ltd.

  16. Cobalt-60 in the treatment of cancer-future scenario

    International Nuclear Information System (INIS)

    Sastri, K.V.S.; Patil, B.N.; Kohli, A.K.

    2009-01-01

    Treatment of cancer using radiation is established method. Cobalt-60 is the workhorse of cancer treatment from the beginning. Later linear accelerators with more accessories were developed and are now used for the advanced treatments like IMRT, IGRT etc. Gammaknife, Gyroknife and supergamma machines using 60 Co have also taken roots for the treatment of cancer. The use of 60 Co in the treatment of cancer is expected to continue for some more time to come. (author)

  17. Determination of cobalt-60 in seawater by solvent extraction with pyrrolidinedithiocarbamic acid

    International Nuclear Information System (INIS)

    Tseng, C.L.; Lo, J.M.

    1978-01-01

    Cobalt-60 was extracted from a large volume of seawater and concentrated in a small volume of organic solution of pyrrolidinedithiocarbamic acid (HPDC) in chloroform. All foreign nuclides in the organic phase were stripped completely with 12N HCl and 2N HNO 3 successively. By this procedure, a chemically pure Co-60 chelate, 60 Co(PDC) 3 , in chloroform was obtained. The recovery of Co-60 activity was found to average 99%. Cobalt-60 in seawater can thus be simply, rapidly and accurately determined by direct NaI(Tl) scintillation counting. The time for a single analysis, for example, exclusive of the counting operation, is about 40 min. The effects of various foreign nuclides on the extraction of Co-60 were examined by the use of 42 radiotracers and the results are tabulated. The nuclides Ag + , Mn 2+ , Ni 2+ , Cu 2+ , Zn 2+ , Cd 2+ , Pb 2+ , Hg 2+ , Fe 3+ , Ga 3+ , In 3+ , As 3+ , Sn 4+ , and Cr 6+ were extracted almost completely into chloroform with cobalt as the pyrrolidinedithiocarbamates. The extraction yield of Sb 3+ was close to 90%. Appreciable fractions of Cs + , Ba 2+ , Cr 3+ , Zr 4+ and Np 5+ were also found in the organic phase. (T.I.)

  18. SU-F-T-659: Nanoparticle-Aided Eye Plaque Radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Chin, J [University of Masschusetts-Lowell, Lowell, Massachusetts (United States); Ngwa, W [Harvard Medical School, Boston, MA (United States)

    2016-06-15

    Purpose: Eye plaque brachytherapy is one of the approaches for radiotherapy treatment for ocular cancers: retinoblastoma and choroidal melanoma. This study, investigates the potential benefits of using gold nanoparticles to enhance therapeutic efficacy during eye plaque brachytherapy. Methods: The EYE PHYSICS Inc. Plaque Simulator program distributed by IsoAid, LLC, Port Richey, Florida was used. It is based on the superposition of dose contributions from individual seeds following the TG–43 formalism. Dose enhancement factor (DEF) values for feasible nanoparticle concentrations from previous studies was used to investigate the benefit of using nanoparticles to enhance dose to tumour or reduce dose to healthy tissue. The dose enhancement factor (DEF) represents the ratio of the dose deposited in tumour with nanoparticles divided by dose deposited in the tumour without nanoparticles. The investigation was done for I–125 and Pd–103 typical sources employed for eye plaque brachytherapy. The prescription dose used is 85 Gy. Results: Lower dose enhancement values were obtained for Pd–103. With DEF of 2 due to gold nanoparticles, critical structure doses reduce by a factor of 2. Optic disc dose is 6.69 Gy and 4.571 Gy, opposite retina dose is 4.064 and 2.484 Gy, lens dose is 12.66 Gy and 9.870 Gy, and fovea dose is 9.85 Gy and 7.275 Gy. With DEF of 3 due to gold nanoparticles, critical structure doses reduce by a factor of 3. Optic disc dose is 4.352 Gy and 2.975 Gy, opposite retina dose is 2.644 Gy and 1.618 Gy, lens dose is 8.322 Gy and 6.427 Gy, and fovea dose is 4.815 Gy and 4.737 Gy. Conclusion: The results of this research predict that using gold nanoparticles will lead to major sparing of dose to critical structures. The finding provides more impetus for the development of nanoparticle–aided brachytherapy.

  19. SU-F-T-659: Nanoparticle-Aided Eye Plaque Radiotherapy

    International Nuclear Information System (INIS)

    Chin, J; Ngwa, W

    2016-01-01

    Purpose: Eye plaque brachytherapy is one of the approaches for radiotherapy treatment for ocular cancers: retinoblastoma and choroidal melanoma. This study, investigates the potential benefits of using gold nanoparticles to enhance therapeutic efficacy during eye plaque brachytherapy. Methods: The EYE PHYSICS Inc. Plaque Simulator program distributed by IsoAid, LLC, Port Richey, Florida was used. It is based on the superposition of dose contributions from individual seeds following the TG–43 formalism. Dose enhancement factor (DEF) values for feasible nanoparticle concentrations from previous studies was used to investigate the benefit of using nanoparticles to enhance dose to tumour or reduce dose to healthy tissue. The dose enhancement factor (DEF) represents the ratio of the dose deposited in tumour with nanoparticles divided by dose deposited in the tumour without nanoparticles. The investigation was done for I–125 and Pd–103 typical sources employed for eye plaque brachytherapy. The prescription dose used is 85 Gy. Results: Lower dose enhancement values were obtained for Pd–103. With DEF of 2 due to gold nanoparticles, critical structure doses reduce by a factor of 2. Optic disc dose is 6.69 Gy and 4.571 Gy, opposite retina dose is 4.064 and 2.484 Gy, lens dose is 12.66 Gy and 9.870 Gy, and fovea dose is 9.85 Gy and 7.275 Gy. With DEF of 3 due to gold nanoparticles, critical structure doses reduce by a factor of 3. Optic disc dose is 4.352 Gy and 2.975 Gy, opposite retina dose is 2.644 Gy and 1.618 Gy, lens dose is 8.322 Gy and 6.427 Gy, and fovea dose is 4.815 Gy and 4.737 Gy. Conclusion: The results of this research predict that using gold nanoparticles will lead to major sparing of dose to critical structures. The finding provides more impetus for the development of nanoparticle–aided brachytherapy.

  20. Cobalt-60 production in the BN-350 fast power reactor

    International Nuclear Information System (INIS)

    Zvonarev, A.V.; Korobejnikov, V.V.; Matveenko, I.P.

    1994-01-01

    A possibility of Co-60 isotope production in the BN-350 fast reactor was considered. A special irradiating device, which is an assembly with a central hole, where a container containing cobalt and zirconium hydride is placed. The irradiating device tested permits generating 60 Co with specific activity of 100 Ci/g

  1. Contamination of steel produced in the Czech Republic by cobalt 60

    International Nuclear Information System (INIS)

    Malatova, I.; Foltanova, S.; Rulik, P.

    1999-01-01

    In recent years, the metal recycling industry has become aware of the presence of radioactive materials in scrap metal. While the problem has historical roots dating to the earliest days of the use of radium, the use of radioactive materials in industrial devices, coupled with incorrect disposal of those devices led to many cases where radioactive sources were unintentionally smelted in the course of recycling. A survey was made of the steel contamination produced during file years 1993 to 1996 in nine steel producing plants. Altogether 721 steel samples were measured by semiconductor gamma spectrometry. In 62% of the samples, no cobalt 60 activity was detected, i.e. the activity was below the minimum significant activity. In 95.5% of the samples, activity concentration of cobalt 60 was below 10 Bq/kg and in 3.4% of the samples, the activity concentration was between 100 and 1000 Bq/kg. The samples were collected according to a scheme which ensured a random choice. In addition, eight samples collected in plants where file investigation was performed were measured, following the melting of contaminated scrap. These samples had activity concentration of cobalt 60 greater than 1000 Bq/kg. (author)

  2. Developed and applications of a method for dose comparation of the cobalt 60 in radiotherapy

    International Nuclear Information System (INIS)

    Leao, J.L.B.

    1975-01-01

    IAEA and WHO developed a postal intercomparison program for measuring the output of Co-60 therapy units all over the world. This work reports first results of an modified postal intercomparison based on IAEA/WHO program. A mailable 10 x 10 x 10,5cm Mix-D phantom with embedded TLD dosimeters, films and field markers of lead and a questionary were developed to obtain not only informations regarding output of Co-60 therapy machines but also to get information about alignment, field homogeneity, dose calculations, field size and surface dose. This program was field tested in 10 different Radiotherapy Centers. The results of this intercomparison gave a spread of the absorbed dose from 78 rads to 127 rads for the 100 rads asked for in 5cm depth of the phantom. Variation in the prescribed fieldsize of 6 x 6cm were between 30cm 2 and 100cm 2 . In half of the cases inhomogeneity of the radiation field was spotted [pt

  3. Preliminary feasibility study on production of cobalt-60 source for industrial irradiation

    International Nuclear Information System (INIS)

    Joo, Po Kook; Park, Kyung Bae; Ahn, Yun Soo; Lee, Jong Tai; Kim, Hark Rho

    1999-05-01

    As there is a high possible demand of industrial Co-60 source in the world market, feasibility study of a project was performed to produce and to export Co-60 sources, utilizing KEPCO's Wolsung NPP for irradiation of cobalt and KAERI's hot-cells for fabrication of cobalt sources. Main concerns of the study were to understand irradiation and fabrication (encapsulation) processes and to examine related technologies, required facilities and equipment. In particular, it was examined intensively if it would be possible to modify facilities around the reactor vessel of Wolsung NPP tp substantiate the related licensing in order to irradiate cobalt in the reactor. It is expected that once, if cooperation scheme with MDS Nordion of Canada is established, main issues such as modification of facilities, related licensing, raw material procurement and technology transfer for high quality product will be solved. In order to review overall feasibility of the project, present status and prospect of the world market was surveyed and various usages of cobalt sources were reviewed with emphasis on possible demand increase per usage. Food poisoning accidents are prevailing worldwide and food irradiation with cobalt sources is considered as a promising measure to prevent them and may bring forth high increase of cobalt sources demand in the world market. Preliminary economic feasibility was studied in conservation, evaluating roughly the investment and the operating cost based on materials from various information sources. (author)

  4. Cobalt-60 simulation of LOCA [loss of coolant accident] radiation effects

    International Nuclear Information System (INIS)

    Buckalew, W.H.

    1989-07-01

    The consequences of simulating nuclear reactor loss of coolant accident (LOCA) radiation effects with Cobalt-60 gamma ray irradiators have been investigated. Based on radiation induced damage in polymer base materials, it was demonstrated that electron/photon induced radiation damage could be related on the basis of average absorbed radiation dose. This result was used to estimate the relative effectiveness of the mixed beta/gamma LOCA and Cobalt-60 radiation environments to damage both bare and jacketed polymer base electrical insulation materials. From the results obtained, it is concluded that present simulation techniques are a conservative method for simulating LOCA radiation effects and that the practices have probably substantially overstressed both bare and jacketed materials during qualification testing. 9 refs., 8 figs., 5 tabs

  5. Health physics monitoring during cobalt slug rod handling at research reactor Dhruva: an experience

    International Nuclear Information System (INIS)

    Verma, Gopal P.; Bhatnagar, Amit; Krishnamohanan, T.; Kalyanasundaram, N.; Gupta, P.C.; Pushparaja; Ghosh, Runner

    2006-01-01

    Cobalt-60 is used in many industrial and medical applications, such as leveling devices, thickness gauge, sterilization of foodstuff to increase their shelf life, sterilization of medicines and in radiotherapy. The Cobalt slug rod containing cobalt pencils were irradiated for nearly two and half years in the Dhruva reactor core to obtain the 60 Co isotope. It had seen a total irradiation of 29053 MWD and the estimated total activity was 93.321 KCi. Campaign for the removal of irradiated rod from reactor core and retrieval of 60 Co pencils were carried out successfully in Dhruva Reactor complex. In view of such a high activity handled, the job was carried out after exhaustive prior planning and according to approved checklists. Radiation Hazards Control Unit, Dhruva provided Radiation Safety surveillance during the entire handling operation consisting of retrieval of the cobalt pencils and disposal of the aluminum slugs used to house the cobalt pencils in the Cobalt slug rod assembly. The whole operation was carried out in such a safe manner that the total man-rem consumption was insignificant. The operational radiation protection methods followed and the experience gained during the campaign are discussed in this paper. (author)

  6. Sedimentation of cobalt-60 and caesium-137 released in Tvaeren, a Baltic bay

    International Nuclear Information System (INIS)

    Ramberg, L.

    1984-01-01

    The amounts of cobalt-60 and caesium-137 bound in the sediment in a bay off the Studsvik research station were determined. Of the cumulative released activity during 22 years, 19% of 60 Co and 1.8% of 137 Cs were found in the sediments within an area of 23 km 2 . The rate of input through sedimentation and the loss rate through physical decay were of the same order in 1981 and were close to steady state for 60 Co while for 137 Cs they had only reached 30% of that level. The sedimentation coefficients calculated for the bay were 6.5 year -1 for 60 Co and 0.49 year -1 for 137 Cs, higher values than many published previously. Cobalt-60 seemed to precipitate close to the outlet and to migrate near the bottom as bed-load. (author)

  7. Activity distribution of a cobalt-60 teletherapy source

    International Nuclear Information System (INIS)

    Jaffray, D.A.; Munro, P.; Battista, J.J.; Fenster, A.

    1991-01-01

    In the course of quantifying the effect of radiation source size on the spatial resolution of portal images, a concentric ring structure in the activity distribution of a Cobalt-60 teletherapy source has been observed. The activity distribution was measured using a strip integral technique and confirmed independently by a contact radiograph of an identical but inactive source replica. These two techniques suggested that this concentric ring structure is due to the packing configuration of the small 60Co pellets that constitute the source. The source modulation transfer function (MTF) showed that this ring structure has a negligible influence on the spatial resolution of therapy images when compared to the effect of the large size of the 60Co source

  8. The role of Cobalt-60 in modern radiation therapy: Dose delivery and image guidance

    Directory of Open Access Journals (Sweden)

    Schreiner L

    2009-01-01

    Full Text Available The advances in modern radiation therapy with techniques such as intensity-modulated radiation therapy and image-guid-ed radiation therapy (IMRT and IGRT have been limited almost exclusively to linear accel-erators. Investigations of modern Cobalt-60 (Co-60 radiation delivery in the context of IMRT and IGRT have been very sparse, and have been limited mainly to computer-modeling and treatment-planning exercises. In this paper, we report on the results of experiments using a tomotherapy benchtop apparatus attached to a conventional Co-60 unit. We show that conformal dose delivery is possible and also that Co-60 can be used as the radiation source in megavoltage computed tomography imaging. These results complement our modeling studies of Co-60 tomotherapy and provide a strong motivation for continuing development of modern Cobalt-60 treatment devices.

  9. Dosimetric evaluation of Radiotherapy units wit 60Co

    International Nuclear Information System (INIS)

    Leon, B. Salinas de; Tovar M, V.; Becerril V, A.

    2000-01-01

    The SSDL network of the IAEA performs, every year, quality audit tests for radiotherapy services ( 60 Co units and linear accelerators), and for national SSDL as well. Because of the SSDL-Mexico results in these tests and due to our enthusiasm and confidence in our work, a parallel test has been done , which is described in this talk as well as the results. Nowadays, a second parallel test goes up, which could confirm our optimism and open the possibility to our country to start a national dosimetric audit of 60 Co radiotherapy units. (Author)

  10. Model for cobalt 60/58 deposition on primary coolant piping in a boiling water reactor

    International Nuclear Information System (INIS)

    Dehollander, W.R.

    1979-01-01

    A first principles model for deposition of radioactive metals into the corrosion films of primary coolant piping is proposed. It is shown that the predominant mechanism is the inclusion of the radioactive species such as Cobalt 60 into the spinel structure of the corrosion film during the act of active corrosion. This deposition can occupy only a defined fraction of the available plus 2 valence sites of the spinel. For cobalt ions, this ratio is roughly 4.6 x 10 -3 of the total iron sites. Since no distinction is made between Cobalt 60, Cobalt 58, and Cobalt 59 in this process, the radioactivity associated with this inclusion is a function of the ratio of the radioactive species to the nonradioactive species in the water causing the corrosion of the pipe metal. The other controlling parameter is the corrosion rate of the pipe material. This can be a function of time, for example, and it shown that freshly descaled metal when exposed to the cobalt containing water can incorporate as much as 10 x 10 -3 cobalt ions per iron atom in the initial corrosion period. This has implications for the problem of decontaminating nuclear reactor piping. Equations and selected observations are presented without reference to any specifically identified reactor or utility, so as to protect any proprietary interest

  11. Radiotherapy of endocrine orbitopathy

    International Nuclear Information System (INIS)

    Weischedel, U.; Wieland, C.

    1985-01-01

    After a review of the history and a discussion of recent theories about pathogenesis of endocrine ophthalmopathy the authros give a report on their radiotherapeutical treatment results with cobalt-60-γ-rays in 50 patients. Amelioration was achieved in 50% of the cases, in the other 50% no progression was seen. Radiotherapy is of antiphlogistic and functional effectivity and should be integrated in the treatment regime in early stages. (orig.) [de

  12. sup(60)Co hot atom chemistry of tris(acetylacetonato) cobalt(III) adsorbed on silica gel

    International Nuclear Information System (INIS)

    Nishioji, H.; Sakai, Y.; Tominaga, T.

    1985-01-01

    The sup(60)Co hot atom reactions were studied in tris(acetylacetonato)cobalt(III) adsorbed on silica gel surface. sup(57)Fe Moessbauer spectra of tris(acetylacetonato)iron(III) in the corresponding system were also measured in order to examine the state of dispersion of complex molecules on silica gel. The retention formation processes were discussed in terms of the dependence of sup(60)Co retention on the adsorbed amount (concentration) of cobalt(III) complexes. (author)

  13. Key technology studies of GY-20 and GY-40 High-capacity cobalt-60 transport casks

    International Nuclear Information System (INIS)

    Liu Huifang; Zhang Xin

    2012-01-01

    GY-20 and GY-40 high-capacity cobalt-60 transport casks are used to transport cobalt-60 industrial irradiators and cobalt-60 bundles. The radioactive contents have special features of high-activity and high residual heat, so only a few countries such as Canada, England and Russia have design capacity. The key technologies and corresponding solutions were studied for the design and manufacture of the cask taking into account the structural, thermal, mechanics and shield requests. A series of tests prove that the cask structure design, design criteria for lead coating structure and quality control measurements are reasonable and effective, and the cask shield integrity can be ensured for all conditions. The casks have ability to transport high-activity sealed sources safely, and the design of cask satisfies the requirement of design code and standard. It can provide reference for other B type package. (authors)

  14. A Vision Controlled Robot to Detect and Collect Fallen Hot Cobalt60 Capsules inside Wet Storage Pool of Cobalt60 Irradiators

    International Nuclear Information System (INIS)

    Solyman, A.E.M.

    2015-01-01

    In a typical irradiator that use radioactive cobalt-60 capsules source is one of the peaceful uses of atomic energy, it originated strategy in terms of its importance in the sterilization of medical products and food processing from bacteria and fungi before being exported. However, there are several well-known problems related to the fall of the cobalt-60 capsules inside the wet storage pool as a result of manufacturing defects, defects welds or a problem occurs in the vertical movement of the radioactive source rack. Therefore it is necessary to study this problem and solve it in a scientific way so as to keep the human as much as possible from radiation exposure, according to the principles of radiation protection and safety issued by the International Atomic Energy Agency. The present work considers the possibility to use a vision based control arm robot to collect fallen hot cobalt-60 capsules inside wet storage pool. A 5-DOF arm robot is designed and vision algorithms are established to pick the fallen capsule on the bottom surface of the storage pool, read the information printed on its edge (cap) and move it to a safe storage place. Two object detection approaches are studied; RGB-based filter and background subtraction technique. Vision algorithms and camera calibration are done using MATLAB/SIMULINK program. Robot arm forward and inverse kinematics are developed and programmed using an embedded micro controller system. Experiments show the validity of the proposed system and prove its success. The collecting process will be done without interference of operators, so radiation safety will be increased. The results showed camera calibration equations accuracy. And also the presence of vibrations in the hands of the movement of the robot and thus were seized motor rotation speed to 10 degrees per second to avoid these vibrations.This scientific application keeps the operators as much as possible from radiation exposure so it leads to increase radiation

  15. Evaluation of leakage in cobalt-60 unit in National Cancer Institute (NCI) Wad Medani

    International Nuclear Information System (INIS)

    Fadlellah, R. A.

    2013-08-01

    This study has been conducted primarily to evaluate the leakages radiation in cobalt-60 unit in National Cancer Institute Wad Medani, which represent the basic risky factor in this unit for the radio therapists who spend much time during patient set up, also they need to stand near the head of the machine to fix some accessories. The measurements which done using survey meter give normal level of occupational exposure compared with IAEA references except one situation that the radio therapist to be close contact to the head of unit for long time which may increase the received dose, in this situation. The radio therapist either not well trained, or there is insufficient accessories to reduce the time inside the room. Radiotherapy department need a special considerations from the beginning of construction till starting of treatment. It is important to contain separate rooms, for planning to determine treatment area, another one for molding to shape lead blocks to protect normal parts and an optimum designed room for treatment to enable workers to apply basic radiation protection principles. (Author)

  16. Biological fate of cobalt-60 released during the corrosion of neutron-activated stanless steel in seawater

    International Nuclear Information System (INIS)

    Young, J.S.

    1982-03-01

    Passing seawater over radioactive Type 347 stainless steel in a sediment/seawater laboratory system and exposing marine animals to this environment provided information on the bioaccumulation of 60 Co from radioactive structural material. Exposure of marine organisms to radioactive corrosion products and directly to radioactive stainless steel in seawater simulated some of the possible conditions which could arise from the deposition of radioactive stainless steel on the ocean floor. Detectable levels of 60 Co in marine animals were not observed on a short term basis (5 weeks). Longterm (13 months) exposure of marine animals in a sediment/seawater system resulted in 60 Co bioaccumulation. The specific activity of 60 Co in the organisms was as much as one million times less than that initially present in the radioactive stainless steel. This was due to the dilution of 60 Co by stable cobalt in the seawater, sediments and organisms. As expected the 60 Co specific activity of the organisms never increased above that of the radioactive source. This is because 60 Co is chemicaly indistinguishable from stable Co. Increasing 60 Co concentration factors with decreasing 60 Co concentrations in the seawater and sediment media coupled with relatively constant 60 Co specific activities suggest a possible homeostatic control of cobalt concentrations in certain marine organisms. The evidence indicates that the marine animals derived more of the accumulated 60 Co from the sediments and interstitial water than from seawater. Cobalt-60 concentration factors were generally found to be lower than published cobalt concentration factors due to the predominantly insoluble nature of the corrosion products. Baseline information is provided on trace element concentrations in deep-sea organisms. Stable Co and twenty other elements were measured in abyssal invertebrates and a fish

  17. Evaluation of skyshine dose due to gamma-rays from a cobalt-60 irradiation facility

    International Nuclear Information System (INIS)

    Kanazawa, Tamotsu; Okamoto, Shinichi; Ohnishi, Tokuhiro; Tsujii, Yukio

    1991-01-01

    We attempted to evaluate skyshine dose due to gamma-rays from a cobalt-60 irradiation facility. As the first step, the results of measurements and calculations were compared of the skyshine dose due to gamma-rays from the cobalt-60 source of 1.45 PBq set in the No.4 irradiation room of our laboratory. Distances of measuring points from the cobalt source were in the range from 17 m to about 100 m in the site of our office. Calculation was carried out with simplified single scattering method. The calculated values of the skyshine dose were higher than the measured values. For more precise evaluation of the skyshine dose, the following factors are to be considered; the dose rate distribution on the roof above the source and the attenuation of gamma-rays by air. (author)

  18. Cobalt-60 oxide aerosols: methods of production and short-term retention and distribution kinetics in the beagle dog

    International Nuclear Information System (INIS)

    Barnes, J.E.; Kanapilly, G.M.; Newton, G.J.

    1976-01-01

    Cobalt-60 has been used extensively in nuclear applications and has been considered for use in nuclear auxiliary power devices. The most common chemical form used is the oxide. This study of the retention and distribution of two differnt exoides of cobalt when administered by inhalation was conducted to assess the potential inhalation hazard associated with its use. Cobaltosic oxide (Co 3 O 4 ) was formed by passing a cobalt nitrate aerosol through a heating column at 850 0 C before delivery to the dog. Cobaltous oxide (CoO) was formed by raising the heating column temperature to 1400 0 C. Three beagle dogs were exposed to 60 Co 3 O 4 and sacrificed singly at 8, 64 and 128 days. Three beagle dogs were exposed to 60 CoO and sacrificed at 8, 16 and 64 days after exposure. Whole-body retention patterns showed that 60 CoO left the body with a shorter effective half-life than 60 Co 3 O 4 . The concentration of 60 Co detected in the blood was at least an order of magnitude higher in the dogs exposed to 60 CoO than in the dogs exposed to 60 Co 3 O 4 . Cobalt-60 translocated from the lung accumulated predominantly in the kidney, liver, skeleton and cartilagenous structures such as the trachea. Higher concentrations were reached earlier in the dogs exposed to 60 CoO. After early fecal excretion of material deposited in the upper respiratory tract, excretion was greatest via the urine. The higher solubility of the 60 CoO formed at 1400 0 C relative to 60 Co 3 O 4 formed at 850 0 C is noteworthy considering that generally aerosols formed at higher temperatures are more insoluble than aerosols formed at lower temperatures. (author)

  19. A treatment planning comparison between modulated tri-cobalt-60 teletherapy and linear accelerator–based stereotactic body radiotherapy for central early-stage non−small cell lung cancer

    Energy Technology Data Exchange (ETDEWEB)

    Merna, Catherine; Rwigema, Jean-Claude M.; Cao, Minsong; Wang, Pin-Chieh; Kishan, Amar U.; Michailian, Argin; Lamb, James; Sheng, Ke; Agazaryan, Nzhde; Low, Daniel A.; Kupelian, Patrick; Steinberg, Michael L.; Lee, Percy, E-mail: percylee@mednet.ucla.edu

    2016-04-01

    We evaluated the feasibility of planning stereotactic body radiotherapy (SBRT) for large central early-stage non−small cell lung cancer with a tri-cobalt-60 (tri-{sup 60}Co) system equipped with real-time magnetic resonance imaging (MRI) guidance, as compared to linear accelerator (LINAC)–based SBRT. In all, 20 patients with large central early-stage non−small cell lung cancer who were treated between 2010 and 2015 with LINAC-based SBRT were replanned using a tri-{sup 60}Co system for a prescription dose of 50 Gy in 4 fractions. Doses to organs at risk were evaluated based on established MD Anderson constraints for central lung SBRT. R{sub 100} values were calculated as the total tissue volume receiving 100% of the dose (V{sub 100}) divided by the planning target volume and compared to assess dose conformity. Dosimetric comparisons between LINAC-based and tri-{sup 60}Co SBRT plans were performed using Student's t-test and Wilcoxon Ranks test. Blinded reviews by radiation oncologists were performed to assess the suitability of both plans for clinical delivery. The mean planning target volume was 48.3 cc (range: 12.1 to 139.4 cc). Of the tri-{sup 60}Co SBRT plans, a mean 97.4% of dosimetric parameters per patient met MD Anderson dose constraints, whereas a mean 98.8% of dosimetric parameters per patient were met with LINAC-based SBRT planning (p = 0.056). R{sub 100} values were similar between both plans (1.20 vs 1.21, p = 0.79). Upon blinded review by 4 radiation oncologists, an average of 90% of the tri-{sup 60}Co SBRT plans were considered acceptable for clinical delivery compared with 100% of the corresponding LINAC-based SBRT plans (p = 0.17). SBRT planning using the tri-{sup 60}Co system with built-in MRI is feasible and achieves clinically acceptable plans for most central lung patients, with similar target dose conformity and organ at risk dosimetry. The added benefit of real-time MRI-guided therapy may further optimize tumor targeting while

  20. A treatment planning comparison between modulated tri-cobalt-60 teletherapy and linear accelerator-based stereotactic body radiotherapy for central early-stage non-small cell lung cancer.

    Science.gov (United States)

    Merna, Catherine; Rwigema, Jean-Claude M; Cao, Minsong; Wang, Pin-Chieh; Kishan, Amar U; Michailian, Argin; Lamb, James; Sheng, Ke; Agazaryan, Nzhde; Low, Daniel A; Kupelian, Patrick; Steinberg, Michael L; Lee, Percy

    2016-01-01

    We evaluated the feasibility of planning stereotactic body radiotherapy (SBRT) for large central early-stage non-small cell lung cancer with a tri-cobalt-60 (tri-(60)Co) system equipped with real-time magnetic resonance imaging (MRI) guidance, as compared to linear accelerator (LINAC)-based SBRT. In all, 20 patients with large central early-stage non-small cell lung cancer who were treated between 2010 and 2015 with LINAC-based SBRT were replanned using a tri-(60)Co system for a prescription dose of 50Gy in 4 fractions. Doses to organs at risk were evaluated based on established MD Anderson constraints for central lung SBRT. R100 values were calculated as the total tissue volume receiving 100% of the dose (V100) divided by the planning target volume and compared to assess dose conformity. Dosimetric comparisons between LINAC-based and tri-(60)Co SBRT plans were performed using Student׳s t-test and Wilcoxon Ranks test. Blinded reviews by radiation oncologists were performed to assess the suitability of both plans for clinical delivery. The mean planning target volume was 48.3cc (range: 12.1 to 139.4cc). Of the tri-(60)Co SBRT plans, a mean 97.4% of dosimetric parameters per patient met MD Anderson dose constraints, whereas a mean 98.8% of dosimetric parameters per patient were met with LINAC-based SBRT planning (p = 0.056). R100 values were similar between both plans (1.20 vs 1.21, p = 0.79). Upon blinded review by 4 radiation oncologists, an average of 90% of the tri-(60)Co SBRT plans were considered acceptable for clinical delivery compared with 100% of the corresponding LINAC-based SBRT plans (p = 0.17). SBRT planning using the tri-(60)Co system with built-in MRI is feasible and achieves clinically acceptable plans for most central lung patients, with similar target dose conformity and organ at risk dosimetry. The added benefit of real-time MRI-guided therapy may further optimize tumor targeting while improving normal tissue sparing, which warrants further

  1. Further experience with radiotherapy by multiple daily sessions

    Energy Technology Data Exchange (ETDEWEB)

    Svoboda, V H.J. [Saint Mary' s Hospital, Portsmouth (UK). Dept. of Radiotherapy and Oncology

    1978-05-01

    Since 1972 over 100 patients have been treated by frequent daily sessions of radiotherapy with a short overall time. Cobalt 60 teletherapy and 250 kV X-ray beams have been used with radical or palliative dosage. The tolerance to these regimes of the skin, breast, chest wall, neck, lung and pelvis is discussed and the tumour responses described. Radiotherapy by multiple daily sessions is clinically possible and often an advantage. Its therapeutic ratio is not inferior to comparable regimes using longer intervals.

  2. Transport of radioactive source of cobalt-60 for the steel industry

    International Nuclear Information System (INIS)

    Santos, Paulo de Oliveira

    2009-01-01

    Radioactive materials are used in the fields of medicine, industry, research and nuclear power production. The use of radioactive material may involve transportation and this implies in the application of safety measures to the workers, public and the environment. Many types of radioactive material are produced all over the world and some modes of transport are involved. The IAEA regulations are based on the philosophy that radioactive material being transported should be adequately packaged to provide protection against the hazards of the material under all conditions of transport. Some Brazilian steel industries control the levels of liquid steel in continuous casting systems by means of sealed sources of cobalt-60. The Center for Development of Nuclear Technology-CDNT produces several of these sources to meet these industries and these sources must be transported in packages designed and tested as requirements of the rules of carriage of radioactive materials. For the transportation of seven sources of cobalt-60 with total activity of 1 GBq since CDNT to the applicant industries was designed, built and tested a Type A package. The thickness of the shield to meet the surface dose rate and the index of transport was calculated by MCNP (Monte Carlo N-Particle Transport Code-Version 5) and practical values were compatible. The sealed sources of cobalt-60 were tested as to leak through the tightness test conducted according to ISO 9978:1992 (E) and the tests to demonstrate the capability of resistance of packaged under normal conditions of transport were made on the facilities of CDNT. (author)

  3. Exploring the variation of oral microbiota in supragingival plaque during and after head-and-neck radiotherapy using pyrosequencing.

    Science.gov (United States)

    Gao, Li; Hu, Yuejian; Wang, Yuxia; Jiang, Wenxin; He, Zhiyan; Zhu, Cailian; Ma, Rui; Huang, Zhengwei

    2015-09-01

    The aim of this article was to study the variation in oral microflora of the subgingival plaque during and after radiotherapy. During and after radiotherapy, microbial samples were collected at seven time points (early stage, medium stage, and later stage of radiotherapy, and 1 month, 3 months, 6 months, and 1 year after radiotherapy) in three subjects for a total of 21 samples. Polymerase chain reaction (PCR) amplification was carried out on the 16S rDNA hypervariable V1-V3 region, and then the PCR products were determined by high-throughput pyrosequencing. The rarefaction curve indicating the richness of the microflora demonstrated that the number of operational taxonomic units (OTUs) was in decline from the early stage of radiotherapy to the time point 1 month after radiotherapy and then trended upward. The Shannon diversity index declined during radiotherapy (ranging from 4.59 to 3.73), and generally rose after radiotherapy, with the lowest value of 3.5 (1 month after radiotherapy) and highest value of 4.75 (6 months after radiotherapy). A total of 120 genera were found; five genera (Actinomyces, Veillonella, Prevotella, Streptococcus, Campylobacter) were found in all subjects across all time points. The richness and diversity of oral ecology decreased with increased radiation dose, and it was gradually restored with time. Copyright © 2015 Elsevier Ltd. All rights reserved.

  4. Carotid artery stenosis after neck radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Shimamura, Munehisa; Hashimoto, Yoichiro; Kasuya, Junji; Terasaki, Tadashi [Kumamoto City Hospital (Japan); Uchino, Makoto

    2000-02-01

    Carotid artery stenosis sometimes occurs after cervical radiotherapy. We report a 70-year-old woman with a history of radiotherapy for thyroid cancer at the age of 28 years. She had no signs and symptoms except the skin lesion at the irradiation site. Duplex ultrasonography revealed heterogeneous plaques showing 50% stenosis of bilateral common carotid arteries. Those lesions were observed within segment of irradiation, where atheromatous plaque usually seldom occurs. These indicated that the carotid stenosis was induced by radiotherapy. Although the efficacy of antiplatelet therapy for radiation-induced plaque is not clear, the plaques remained unchanged for 4 years in spite of aspirin administration. (author)

  5. Total body irradiation with a reconditioned cobalt teletherapy unit.

    Science.gov (United States)

    Evans, Michael D C; Larouche, Renée-Xavière; Olivares, Marina; Léger, Pierre; Larkin, Joe; Freeman, Carolyn R; Podgorsak, Ervin B

    2006-01-01

    While the current trend in radiotherapy is to replace cobalt teletherapy units with more versatile and technologically advanced linear accelerators, there remain some useful applications for older cobalt units. The expansion of our radiotherapy department involved the decommissioning of an isocentric cobalt teletherapy unit and the replacement of a column-mounted 4-MV LINAC that has been used for total body irradiation (TBI). To continue offering TBI treatments, we converted the decommissioned cobalt unit into a dedicated fixed-field total body irradiator and installed it in an existing medium-energy LINAC bunker. This article describes the logistical and dosimetric aspects of bringing a reconditioned cobalt teletherapy unit into clinical service as a total body irradiator.

  6. Lack of Radiation Maculopathy After Palladium-103 Plaque Radiotherapy for Iris Melanoma

    Energy Technology Data Exchange (ETDEWEB)

    Yousef, Yacoub A. [New York Eye Cancer Center, New York Eye and Ear Infirmary, and New York University School of Medicine, New York, NY (United States); Finger, Paul T., E-mail: pfinger@eyecancer.com [New York Eye Cancer Center, New York Eye and Ear Infirmary, and New York University School of Medicine, New York, NY (United States)

    2012-07-15

    Purpose: To report on the risk of radiation maculopathy for iris and iridociliary melanomas treated by {sup 103}Pd plaque radiotherapy. Methods and Materials: This is a retrospective clinical case series of 30 eyes in 30 patients with melanomas limited to the iris or invading the ciliary body. The main outcome measures included demographic information, laterality, tumor size, location, visual acuity, radiation dose, local control, retinal evaluation, and duration of follow-up. Results: Thirty patients were followed for a median 36 months (range, 12-90 months). Sixteen of 30 tumors (53%) were pure iris melanomas, and 14 (47%) were primary iris melanomas extending into the ciliary body. Radiation dosimetry showed that the median tumor apex dose was 85 Gy (range, 75-100 Gy), lens dose 43.5 Gy (range, 17.8-60 Gy), fovea dose 1.8 Gy (range, 1.3-5 Gy), and central optic disc dose 1.7 Gy (range, 1.3-4.7 Gy). Cataracts developed in 20 of the 28 phakic eyes (71.4%). No patient in this series developed radiation maculopathy or radiation optic neuropathy. Last best-corrected visual acuity was {>=}20/25 in 28 patients (93%) at a median 36 months' follow-up. Conclusion: Though visual acuities were transiently affected by radiation cataract, no radiation maculopathy or optic neuropathy has been noted after {sup 103}Pd treatment of iris and iridociliary melanomas.

  7. Re-Shielding of Cobalt-60 Teletherapy Rooms for Tomotherapy and Conventional Linear Accelerators using Monte Carlo Simulations

    Science.gov (United States)

    Çeçen, Yiğit; Yazgan, Çağrı

    2017-09-01

    Purpose. Nearly all Cobalt-60 teletherapy machines were removed around the world during the last two decades. The remaining ones are being used for experimental purposes. However, the rooms of these teletherapy machines are valuable because of lack of space in radiotherapy clinics. In order to place a new technology treatment machine in one of these rooms, one should re-shield the room since it was designed only for 1.25 MeV gamma beams on average. Mostly, the vendor of the new machine constructs the new shielding of the room using their experience. However, every radiotherapy room has different surrounding work areas and it would be wise to shield the room considering these special conditions. Also, the shield design goal of the clinic may be much lower than the International Atomic Energy Agency (IAEA) or the local association accepts. The study shows re-shielding of a Cobalt-60 room, specific to the clinic, using Monte Carlo simulations. Materials & Methods: First, a 6 MV Tomotherapy machine, then a 10 MV conventional linear accelerator (LINAC) was placed inside the Cobalt-60 teletherapy room. The photon flux outside the room was simulated using Monte Carlo N-Particle (MCNP6.1) code before and after re-shielding. For the Tomotherapy simulation, flux distributions around the machine were obtained from the vendor and implemented as the source of the model. The LINAC model was more generic with the 10 MeV electron source, the tungsten target, first and secondary collimators. The aim of the model was to obtain the maximum (40x40 cm2) open field at the isocenter. Two different simulations were carried out for gantry angles 90o and 270o. The LINAC was placed in the room such that the primary walls were A' (Gantry 270o) and C' (Gantry 90o) (figure 1). The second part of the study was to model the re-shielding of the room for Tomotherapy and for the conventional LINAC, separately. The aim was to investigate the recommended shielding by the vendors. Left side of the room

  8. Quality and security on the uses of cobalt 60 sources for industrial irradiators

    International Nuclear Information System (INIS)

    Desroches, J.

    1976-01-01

    The construction and operation of industrial irradiators using large quantities of cobalt 60 give rise to an important problem of security. The CEA Radioisotope Department which manufactures and sells sources of Co60 has created an insurance Quality System which insures the maximum of security for the user. (author)

  9. Absolute exposure determination of cobalt-60 gamma radiation

    International Nuclear Information System (INIS)

    Ahmad, S.S.; Ali, A.; Orfi, S.D.

    1986-02-01

    The report describes the procedure for the determination of absolute exposure for Cobalt-60 gamma radiation. A graphite cavity chamber, nominal volume of 1 cm 3 , manufactured by Austrian Research Centre Seibersdorf has been used. The exposure rate at reference distance determined with the graphite chamber was compared with mean exposure rate measured with NPL-Therapy level X-ray exposure meter normalized to same date. An agreement of 0.39% was found between the two measuring systems, which seems to be very encouraging and quite satisfactory. (authors)

  10. Process of contamination of two trophic dulcaquicole chains by cobalt 60. I

    International Nuclear Information System (INIS)

    Amiard-Triquet, C.; Foulquier, L.

    1978-01-01

    In order to evaluate Cobalt 60 behavior in freshwater ecosystems, two food chains including different nutritionally interdependent species in a natural environment were defined. This article covers the dynamics of water-borne contamination in the species. (Auth.)

  11. Radiation safety assessment of cobalt 60 external beam radiotherapy using the risk-matrix method

    International Nuclear Information System (INIS)

    Dumenigo, C; Vilaragut, J.J.; Ferro, R.; Guillen, A.; Ramirez, M.L.; Ortiz Lopez, P.; Rodriguez, M.; McDonnell, J.D.; Papadopulos, S.; Pereira, P.P.; Goncalvez, M.; Morales, J.; Larrinaga, E.; Lopez Morones, R.; Sanchez, R.; Delgado, J.M.; Sanchez, C.; Somoano, F.

    2008-01-01

    External beam radiotherapy is the only practice in which humans are placed directly in a radiation beam with the intention to deliver a very high dose. This is why safety in radiotherapy is very critical, and is a matter of interest to both radiotherapy departments and regulatory bodies. Accidental exposures have occurred throughout the world, thus showing the need for systematic safety assessments, capable to identify preventive measures and to minimize consequences of accidental exposure. Risk-matrix is a systematic approach which combines the relevant event features to assess the overall risk of each particular event. Once an event sequence is identified, questions such as how frequent the event, how severe the potential consequences and how reliable the existing safety measures are answered in a risk-matrix table. The ultimate goal is to achieve that the overall risk for events with severe consequences should always be low o very low. In the present study, the risk-matrix method has been applied to an hypothetical radiotherapy department, which could be equivalent to an upper level hospital of the Ibero American region, in terms of safety checks and preventive measures. The application of the method has identified 76 event sequences and revealed that the hypothetical radiotherapy department is sufficiently protected (low risk) against them, including 23 event sequences with severe consequences. The method has revealed that the risk of these sequences could grow to high level if certain specific preventive measures were degraded with time. This study has identified these preventive measures, thus facilitating a rational allocation of resources in regular controls to detect any loss of reliability. The method has proven to have an important practical value and is affordable at hospital level. The elaborated risk-matrix can be easily adapted to local circumstances, in terms of existing controls and safety measures. This approach can help hospitals to identify

  12. Some safety aspects during the replacement of Cobalt-60 sources in teletherapy

    International Nuclear Information System (INIS)

    Milu, C.

    1998-01-01

    Some recent radiation protection problems arose during the replacement of the old Cobalt-60 sources in teletherapy in Romania. There are pointed out the potential radiation risks for the population and the lack of appropriate regulation for the field. (author)

  13. The ''Cobalt 60 Case'' in Taiwan. Conclusions; Das Kobalt-60 Ereignis von Taiwan. Und was ist daraus zu schliessen?

    Energy Technology Data Exchange (ETDEWEB)

    Niemann, Lutz

    2017-08-15

    The ''Cobalt 60 Case'' in Taiwan gives an opportunity for check of the thesis of radiation hormesis. Apartment residents have been exposed to cobalt-60 contaminated steel buildings. The results of a study strongly suggest that whole-body chronic irradiation, in the dose rate range that the apartment residents received, caused no symptomatic adverse health effects, such as radiation sickness, or the increased cancer or increased congenital disease that are predicted by ICRP theories. On the contrary, those who were exposed had lower incidences of cancer mortality and congenital malformations.

  14. Safety analysis report: packages cobalt-60 shipping cask (packaging of radioactive and fissile materials)

    International Nuclear Information System (INIS)

    Evans, J.E.; Langhaar, J.W.

    1973-07-01

    Safety Analysis Report DPSPU-73-124-1 replaces DPSPU-69-124-1 and Supplement 1 to permit shipment of 350,000 curies of 60 Co (maximum) in cobalt-60 shipping casks in compliance with 10 CFR Part 71, Packaging of Radioactive Materials for Transport

  15. Semi-empirical equivalent field method for dose determination in midline block fields for cobalt - 60 beam

    International Nuclear Information System (INIS)

    Tagoe, S.N.A.; Nani, E.K.; Yarney, J.; Edusa, C.; Quayson-Sackey, K.; Nyamadi, K.M.; Sasu, E.

    2012-01-01

    For teletherapy treatment time calculations, midline block fields are resolved into two fields, but neglecting scattering from other fields, the effective equivalent square field size of the midline block is assumed to the resultant field. Such approach is underestimation, and may be detrimental in achieving the recommended uncertainty of ± 5 % for patient's radiation dose delivery. By comparison, the deviations of effective equivalent square field sizes by calculations and experiments were within 13.2 % for cobalt 60 beams of GWGP80 cobalt 60 teletherapy. Therefore, a modified method incorporating the scatter contributions was adopted to estimate the effective equivalent square field size for midline block field. The measured outputs of radiation beams with the block were compared with outputs of square fields without the blocks (only the block tray) at depths of 5 and 10 cm for the teletherapy machine employing isocentric technique, and the accuracy was within ± 3 % for the cobalt 60 beams. (au)

  16. Effect of cobalt-60 radiation on response to endodontic therapy in monkeys

    International Nuclear Information System (INIS)

    Matson, J.E.; Patterson, S.S.; Kafrawy, A.H.; Hornback, N.B.; Shidnia, H.

    1978-01-01

    Response of teeth that had received therapeutic doses of Cobalt-60 radiation to endodontic therapy were investigated in three monkeys. The results indicated no appreciable effect of the irradiation on the response to root canal treatment aside from reduction in osteoblastic activity

  17. Cobalt-60 gamma irradiation of shrimp

    International Nuclear Information System (INIS)

    Sullivan, N.L.B.

    1993-01-01

    Meta- and ortho-tyrosine were measured using high performance liquid chromatography (HPLC) in conjunction with electrochemical detection in shrimp irradiated using cobalt-60 gamma radiation in the absorbed dose range 0.8 to 6.0 kGy, in nonirradiated shrimp, and in bovine serum albumin (BSA) irradiated in dilute aqueous solution at 25.0 kGy. Ortho-tyrosine was measured in nonirradiated BSA. Para-, meta-, and ortho-tyrosine was measured using HPLC in conjunction with uv-absorption detection in dilute aqueous solutions of phenylalanine irradiated in the absorbed dose range 16.0 to 195.0 kGy. The measured yields of tyrosine isomers were approximately linear as a function of absorbed dose in shrimp, and in irradiated solutions of phenylalanine up to 37.0 kGy. The occurrence of meta- and ortho-tyrosine, which had formerly been considered unique radiolytic products, has not previously been reported in nonirradiated shrimp or BSA. The conventional hydrolyzation and analytical techniques used in the present study to measure meta- and ortho-tyrosine may provide the basis for a method to detect and determine the dose used in food irradiation

  18. Consumer products polluted by cobalt-60 on the Dutch market

    International Nuclear Information System (INIS)

    Bothof, J.

    2002-01-01

    In several previous articles of this magazine attention has been paid to reporting of radioactive materials in scrap metals and incidents with radioactive materials, which were dealt with by the VROM-Inspectie Regio Zuid-West (Inspection for the Region South-West in the Netherlands). In this article attention is paid to a special incident with new stainless steel flanges, polluted by cobalt 60 [nl

  19. Transport of Cobalt 60 from the Argentine Nuclear Power Plant in Embalse

    International Nuclear Information System (INIS)

    Lopez Vietri, J.R.

    2011-01-01

    Full text: The purpose of this presentation is to point out some relevant issues related to the transport of cobalt 60 for domestic uses and export from the Argentine Nuclear Power Plant located in Embalse (ENPP). It is remarked that in last 22 years, ENPP produced about 2600 PBq (70 MCi) of Co-60, and that Argentina is the third Co-60 producer, after Canada and Russia. It is mentioned that in Argentina there are facilities which manufacture Zircaloy seamless tubes and reactivity control bars containing cobalt 59 to be used in ENPP, the operation of Candu reactor at ENPP including cobalt-related activities, and the manufacture and commercialization of Co-60 sealed sources. The Argentine Nuclear Regulatory Authority verifies the compliance of nuclear activities with regulatory standards, including those related to the transport of radioactive material. Then, it is described the process for obtaining Co-60 at ENPP with an activity concentration to allow its use in medicine and industry. After that, is considered in detail the type of package used for the transport of Co-60 from ENPP: it is to say, Type B(U) package designs that must be approved by the Competent Authority origin of the design, and they are able to withstand routine, normal and accident conditions of transport, including severe impacts, fires and immersion in water. The overall dimensions of packages are about 1.0 m to 1.5 m diameter by 1.2 m to 1.8 m high, as well as the gross mass could vary from 6500 kg to 9500 kg. Radioactive contents consist of Co-60 sealed sources (called pencils), with an activity range from 8 PBq to 16 PBq. Then, it is considered activities prior to dispatch of Type B(U) packages at ENPP, including the preparation of radioactive contents, packaging and package (labelling and marking) as well as necessary tests and documentation for transport in order to fulfil pertinent requirements of package design operation manual of the package and related standards. Finally, it is pointed

  20. Post-external radiotherapy hypothyroidism: 15 cases; Hypothyroidie apres radiotherapie externe. A propos de 15 cas

    Energy Technology Data Exchange (ETDEWEB)

    Kaffel, N.; Mnif, M.; Abid, M. [Centre Hospitalier Universitaire Hedi Chaker, Sfax (Tunisia); Daoud, J. [Centre Hospitalier Universitaire Habib Bourguiba, Sfax (Tunisia)

    2001-06-01

    Post-external radiotherapy hypothyroidism: 15 cases. Hypothyroidism frequency is estimated to be between 10 and 45% after radiotherapy alone, and 40 to 67% after radiotherapy associated with thyroidectomy. This hypothyroidism is infra-clinical in 60% of the cases. Our study concerned 15 cases of hypothyroidism after external radiotherapy delivered between and 1991 and 1999. An irradiation of the cervical, cerebral and thorax regions was indicated for different types of cancers. Larynx carcinoma epidermoid was the most frequent cancer (seven cases); the radiation treatment used cobalt 60 with conventional fractionation, i.e., 2 Gy per treatment, five treatments a week. In nine cases, the hypothyroidism was discovered during a systematic examination; it was clinically evident in the six remaining cases. Hypothyroidism appeared after an irradiation dose average of 50 Gy (extremes 30-65 Gy). The average duration of the irradiation was about 7 weeks and the hypothyroidism appeared in a mean 22 months. In all cases, the substituting treatment was initiated with a favorable progression. Faced with the risk of hypothyroidism, it is necessary to check patients who have undergone external irradiation of the neck. (authors)

  1. Lack of Radiation Maculopathy After Palladium-103 Plaque Radiotherapy for Iris Melanoma

    International Nuclear Information System (INIS)

    Yousef, Yacoub A.; Finger, Paul T.

    2012-01-01

    Purpose: To report on the risk of radiation maculopathy for iris and iridociliary melanomas treated by 103 Pd plaque radiotherapy. Methods and Materials: This is a retrospective clinical case series of 30 eyes in 30 patients with melanomas limited to the iris or invading the ciliary body. The main outcome measures included demographic information, laterality, tumor size, location, visual acuity, radiation dose, local control, retinal evaluation, and duration of follow-up. Results: Thirty patients were followed for a median 36 months (range, 12–90 months). Sixteen of 30 tumors (53%) were pure iris melanomas, and 14 (47%) were primary iris melanomas extending into the ciliary body. Radiation dosimetry showed that the median tumor apex dose was 85 Gy (range, 75–100 Gy), lens dose 43.5 Gy (range, 17.8–60 Gy), fovea dose 1.8 Gy (range, 1.3–5 Gy), and central optic disc dose 1.7 Gy (range, 1.3–4.7 Gy). Cataracts developed in 20 of the 28 phakic eyes (71.4%). No patient in this series developed radiation maculopathy or radiation optic neuropathy. Last best-corrected visual acuity was ≥20/25 in 28 patients (93%) at a median 36 months’ follow-up. Conclusion: Though visual acuities were transiently affected by radiation cataract, no radiation maculopathy or optic neuropathy has been noted after 103 Pd treatment of iris and iridociliary melanomas.

  2. Cobalt

    International Nuclear Information System (INIS)

    Stolyarova, I.A.; Bunakova, N.Yu.

    1983-01-01

    The neutron-activation method for determining cobalt in rocks, polymetallic and iron ores and rockforming minerals at 2x10 -6 -5x10 -3 % content is developed. Cobalt determination is based on the formation under the effect of thermal neutrons of nuclear reactor of the 60 Co radioactive isotope by the 59 Co (n, γ) 60 Co reaction with radiation energy of the most intensive line of 1333 keV. Cobalt can be determined by the scheme of the multicomponent analysis from the sample with other elements. Co is determined in the solution after separation of all determinable by the scheme elements. The 60 Co intensity is measured by the mUltichannel gamma-spectrometer with Ge(Li)-detector

  3. Enhancement of viability of radiosensitive (PBMC and resistant (MDA-MB-231 clones in low-dose-rate cobalt-60 radiation therapy

    Directory of Open Access Journals (Sweden)

    Patrícia Lima Falcão

    2015-06-01

    Full Text Available Abstract Objective: In the present study, the authors investigated the in vitro behavior of radio-resistant breast adenocarcinoma (MDA-MB-231 cells line and radiosensitive peripheral blood mononuclear cells (PBMC, as a function of different radiation doses, dose rates and postirradiation time kinetics, with a view to the interest of clinical radiotherapy. Materials and Methods: The cells were irradiated with Co-60, at 2 and 10 Gy and two different exposure rates, 339.56 cGy.min–1 and the other corresponding to one fourth of the standard dose rates, present over a 10-year period of cobalt therapy. Post-irradiation sampling was performed at pre-established kinetics of 24, 48 and 72 hours. The optical density response in viability assay was evaluated and a morphological analysis was performed. Results: Radiosensitive PBMC showed decrease in viability at 2 Gy, and a more significant decrease at 10 Gy for both dose rates. MDAMB- 231 cells presented viability decrease only at higher dose and dose rate. The results showed MDA-MB-231 clone expansion at low dose rate after 48–72 hours post-radiation. Conclusion: Low dose rate shows a possible potential clinical impact involving decrease in management of radio-resistant and radiosensitive tumor cell lines in cobalt therapy for breast cancer.

  4. Economics of gamma processing in cobalt-60 irradiation facilities

    International Nuclear Information System (INIS)

    Gay, H. G.; Kotler, J. G.

    1985-01-01

    Gamma processing by cobalt-60 is well established. However, since irradiation of food is relatively new from the commercial point of view, it is important to assess costs of gamma irradiation in the context of food processing. Five different types of AECL-RCC irradiation equipment are examined in terms of their throughputs, and capital and operating costs. Using these figures, costs of irradiation of nine types of food products are presented. In general, these represent about 2-10% of the wholesale cost of these products

  5. Development and production of cobalt-60 sources for metallurgical application

    International Nuclear Information System (INIS)

    Oliveira, Paulo Fernando; Valente, Eduardo Sarmento; Maretti Junior, Fausto

    2002-01-01

    The CDTN has developed and produced 60 Co sources to be used in level controllers on continuous ingot casting. The sources used in these systems are sealed with a stainless steel revetment and have an useful life equivalent to one half life of the 60 Co (5.272 years). Each system of continuous ingot casting uses a source with one specified activity and different activation section. The sources have been imported with a very high cost due the special shields used to keep and transport them safety. One of its sources, with initial activity of 148 MBq, after being used for more than 5 years in one factory, was given to CDTN to carry out an activation section studies. After these studies be concluded CDTN/CNEN began the procedures to produce a new source in the IPR-R1 TRIGA Reactor, with an irradiation of one cobalt wire in the maximum flux region of the core. The same metallic cobalt wire was irradiated (10% of total activity), to determinate the necessary irradiation time to obtain the final activation. The CDTN developed too a stainless steel recipient with a aluminum nucleus, to seal and to guarantee the integrity of the source. (author)

  6. The results of radiotherapy for T1 glottic cancers. Influence of radiation beam energy

    International Nuclear Information System (INIS)

    Yamamoto, Michinori; Joja, Ikuo; Takemoto, Mitsuhiro; Kuroda, Masahiro; Hiraki, Yoshio

    1999-01-01

    We analyzed the influence of various parameters on the results of radiotherapy for T1 glottic cancer by assessing the outcomes of 60 patients with this cancer who received definitive radiotherapy between 1985 and 1994. Seven patients were treated with a cobalt-60 unit, and the other 53 with a linear accelerator (26 patients at 3-MV, 10 at 6-MV, and 17 at 10-MV). Of the 17 patients treated at 10-MV, 4 also received part of their treatment with a cobalt-60 unit. The total radiation dose ranged from 56 Gy to 70 Gy (mean, 61 Gy). The total radiation dose of 51 patients (85%) was 60 Gy. The factors found to influence local control were the strength of the radiation beam energy and whether or not there was gross tumor invasion of the anterior commissure. The local control rate was 71% in the patients treated with a 10-MV linear accelerator, 56% in those treated with a 6-MV linear accelerator and, 97% in those treated with a cobalt-60 unit or a 3-MV linear accelerator (P=0.0173). The local control rate was 43% in the patients with gross anterior commissure invasion and 88% in those without (P=0.0075). We conclude that low energy photon beams are more suitable for the treatment of early glottic cancers, especially if the lesion grossly invades the anterior commissure. (author)

  7. Post-external radiotherapy hypothyroidism: 15 cases

    International Nuclear Information System (INIS)

    Kaffel, N.; Mnif, M.; Abid, M.; Daoud, J.

    2001-01-01

    Post-external radiotherapy hypothyroidism: 15 cases. Hypothyroidism frequency is estimated to be between 10 and 45% after radiotherapy alone, and 40 to 67% after radiotherapy associated with thyroidectomy. This hypothyroidism is infra-clinical in 60% of the cases. Our study concerned 15 cases of hypothyroidism after external radiotherapy delivered between and 1991 and 1999. An irradiation of the cervical, cerebral and thorax regions was indicated for different types of cancers. Larynx carcinoma epidermoid was the most frequent cancer (seven cases); the radiation treatment used cobalt 60 with conventional fractionation, i.e., 2 Gy per treatment, five treatments a week. In nine cases, the hypothyroidism was discovered during a systematic examination; it was clinically evident in the six remaining cases. Hypothyroidism appeared after an irradiation dose average of 50 Gy (extremes 30-65 Gy). The average duration of the irradiation was about 7 weeks and the hypothyroidism appeared in a mean 22 months. In all cases, the substituting treatment was initiated with a favorable progression. Faced with the risk of hypothyroidism, it is necessary to check patients who have undergone external irradiation of the neck. (authors)

  8. Field and laboratory evaluation of the mobility of cobalt-60/EDTA in an arid environment

    International Nuclear Information System (INIS)

    Jones, T.L.; Gee, G.W.; Swanson, J.L.; Kirkham, R.R.

    1983-02-01

    The ability of the organic complexant EDTA to enhance the mobility of cobalt-60 was investigated in both laboratory and field experiments. Laboratory tests consisted of short term (approximately 7 day) column and batch adsorption tests using soil from the Hanford site as well as long term (approximately 70 day) batch tests with Hanford soil and soils from Oak Ridge and Savannah River. In addition, two large scale tracer tests were conducted using Hanford soil. One used a large (1.6 m) laboratory column, spiked with cobalt-60/EDTA and the other was a field test conducted in an 8 m deep lysimeter. Enhanced mobility decreased sorption were observed in both column and batch tests when the cobalt-60/EDTA solutions contacted Hanford and Oak Ridge soil for only a few days. When long contact times were allowed (months) the Hanford soil showed large increases in sorption with time. The low sorption exhibited initially by the Oak Ridge soil increased slightly over time, however, the high sorption observed with the Savannah River soil remained constant with time. The reduced mobility, with time, observed in Hanford soils was confirmed in both the large scale laboratory and breaking down when contacted with Hanford and Savannah River soil and to a lesser extent, the Oak Ridge soil. It is not known at this time why the complex is breaking down or why the kinetics are different among the soils tested. The implication to waste management is that the potential for transport of cobalt by EDTA complexation may not be as serious as once thought

  9. Practical and clinical considerations in Cobalt-60 tomotherapy

    Directory of Open Access Journals (Sweden)

    Joshi Chandra

    2009-01-01

    Full Text Available Cobalt-60 (Co-60 based radiation therapy continues to play a significant role in not only developing countries, where access to radiation therapy is extremely limited, but also in industrialized countries. Howver, technology has to be developed to accommodate modern techniques, in-clud-ing image guided and adaptive radiation therapy (IGART. In this paper we describe some of the practical and clinical considerations for Co-60 based tomotherapy by comparing Co-60 and 6 MV linac-based tomotherapy plans for a head and neck (HandN cancer and a prostate cancer case. The tomotherapy IMRT plans were obtained by modeling a MIMiC binary multi-leaf collimator attached to a Theratron-780c Co-60 unit and a 6 MV linear accelerator (CL2100EX. The EGSnrc/BEAMnrc Monte Carlo (MC code was used for the modeling of the treatment units with the MIMiC collimator and EGSnrc/DOSXYZnrc code was used for beamlet dose data. An in-house inverse treatment planning program was then used to generate optimized tomotherapy dose distributions for the H and N and prostate cases. The dose distributions, cumulative dose area histograms (DAHs and dose difference maps were used to evaluate and compare Co-60 and 6 MV based tomotherapy plans. A quantitative analysis of the dose distributions and dose-volume histograms shows that both Co-60 and 6 MV plans achieve the plan objectives for the targets (CTV and nodes and OARs (spinal cord in HandN case, and rectum in prostate case.

  10. Point kernel technique for calculating dose rates due to cobalt-60 hot particles

    International Nuclear Information System (INIS)

    Thornhill, M.J.; McCarthy, J.T.; Morrissette, R.R.; Leach, B.N.

    1989-01-01

    This paper reports on a computer code called BETA that has been developed by health physicists at the Vermont Yankee Nuclear Power Station which accounts for the mass and size of hot particles of Cobalt-60, and therefore corrects the Loevinger-based dose calculation for self-absorption

  11. Conventional and conformal technique of external beam radiotherapy in locally advanced cervical cancer: Dose distribution, tumor response, and side effects

    Science.gov (United States)

    Mutrikah, N.; Winarno, H.; Amalia, T.; Djakaria, M.

    2017-08-01

    The objective of this study was to compare conventional and conformal techniques of external beam radiotherapy (EBRT) in terms of the dose distribution, tumor response, and side effects in the treatment of locally advanced cervical cancer patients. A retrospective cohort study was conducted on cervical cancer patients who underwent EBRT before brachytherapy in the Radiotherapy Department of Cipto Mangunkusumo Hospital. The prescribed dose distribution, tumor response, and acute side effects of EBRT using conventional and conformal techniques were investigated. In total, 51 patients who underwent EBRT using conventional techniques (25 cases using Cobalt-60 and 26 cases using a linear accelerator (LINAC)) and 29 patients who underwent EBRT using conformal techniques were included in the study. The distribution of the prescribed dose in the target had an impact on the patient’s final response to EBRT. The complete response rate of patients to conformal techniques was significantly greater (58%) than that of patients to conventional techniques (42%). No severe acute local side effects were seen in any of the patients (Radiation Therapy Oncology Group (RTOG) grades 3-4). The distribution of the dose and volume to the gastrointestinal tract affected the proportion of mild acute side effects (RTOG grades 1-2). The urinary bladder was significantly greater using conventional techniques (Cobalt-60/LINAC) than using conformal techniques at 72% and 78% compared to 28% and 22%, respectively. The use of conformal techniques in pelvic radiation therapy is suggested in radiotherapy centers with CT simulators and 3D Radiotherapy Treatment Planning Systems (RTPSs) to decrease some uncertainties in radiotherapy planning. The use of AP/PA pelvic radiation techniques with Cobalt-60 should be limited in body thicknesses equal to or less than 18 cm. When using conformal techniques, delineation should be applied in the small bowel, as it is considered a critical organ according to RTOG

  12. Dosimetric Consistency of Co-60 Teletherapy Unit- a ten years Study.

    Science.gov (United States)

    Baba, Misba H; Mohib-Ul-Haq, M; Khan, Aijaz A

    2013-01-01

    The goal of the Radiation standards and Dosimetry is to ensure that the output of the Teletherapy Unit is within ±2% of the stated one and the output of the treatment dose calculation methods are within ±5%. In the present paper, we studied the dosimetry of Cobalt-60 (Co-60) Teletherapy unit at Sher-I-Kashmir Institute of Medical Sciences (SKIMS) for last 10 years. Radioactivity is the phenomenon of disintegration of unstable nuclides called radionuclides. Among these radionuclides, Cobalt-60, incorporated in Telecobalt Unit, is commonly used in therapeutic treatment of cancer. Cobalt-60 being unstable decays continuously into Ni-60 with half life of 5.27 years thereby resulting in the decrease in its activity, hence dose rate (output). It is, therefore, mandatory to measure the dose rate of the Cobalt-60 source regularly so that the patient receives the same dose every time as prescribed by the radiation oncologist. The under dosage may lead to unsatisfactory treatment of cancer and over dosage may cause radiation hazards. Our study emphasizes the consistency between actual output and output obtained using decay method. The methodology involved in the present study is the calculations of actual dose rate of Co-60 Teletherapy Unit by two techniques i.e. Source to Surface Distance (SSD) and Source to Axis Distance (SAD), used for the External Beam Radiotherapy, of various cancers, using the standard methods. Thereby, a year wise comparison has been made between average actual dosimetric output (dose rate) and the average expected output values (obtained by using decay method for Co-60.). The present study shows that there is a consistency in the average output (dose rate) obtained by the actual dosimetry values and the expected output values obtained using decay method. The values obtained by actual dosimetry are within ±2% of the expected values. The results thus obtained in a year wise comparison of average output by actual dosimetry done regularly as a part of

  13. Direct uptake of cobalt 60 by the carp (Cyprinus carpio L.) following experimental chronic or cyclical contamination of water

    International Nuclear Information System (INIS)

    Amiard-Triquet, C.; Foulquier, L.

    1978-01-01

    Irrespective of the nature of experimental cobalt 60 contamination (chronic or cyclical), the activity level in the carp was highest after 32 or 35 days when the concentration factor reached 3. An analysis of cobalt 60 distribution shows preferential uptake by the kidneys. It therefore seems unlikely that the discharge rate of effluents from the nuclear industry and the resulting variations of radioactivity levels in the water significantly modify the impact of contamination on aquatic organisms [fr

  14. Cobalt-60 and Caesium-137 Gamma Sources; Sources de rayonnement gamma au cobalt-60 et au cesium-137; Gamma-istochniki iz kobal'ta-605 i tseziya-137; Fuentes gamma de cobalto-60 y de cesio-137

    Energy Technology Data Exchange (ETDEWEB)

    Kulish, E E; Fradkin, G M [Academy of Sciences of the USSR, Moscow, Union of Soviet Socialits Republics (Russian Federation)

    1960-07-15

    The paper gives the main technical characteristics of gamma sources produced in the USSR using cobalt-60 and caesium-137 and discusses some of the problems of their production technology. The paper contains information on the radiation spectra of Co{sup 60} and Cs{sup 137} and of the source material from which they are prepared. Data are given on the dependence of the activity of cobalt sources upon the intensity of the neutron beam and the geometrical size of the sample. The yield of caesium by uranium fission is also analyzed. The problem of hermetic sealing of the sources is discussed and a complete nomenclature of all the sources manufactured in the USSR are listed, their size and activity also being indicated. In conclusion a comparison of Co{sup 60} and Cs{sup 137} sources is made. (author) [French] Cette communication expose les caracteristiques techniques fondamentales des sources de rayonnement gamma a base de cobalt-60 et de cesium-137 pro- duites en URSS; on y examine egalement certaines questions relatives a la technologie de leur production. La communication contient des donnees sur la nature du rayonnement des isotopes {sup 60}Co et {sup 137}Cs, ainsi que sur celle des matieres brutes utilisees pour leur preparation. On donne les resultats obtenus lors de l'etude de la variation de l'activite des sources au cobalt en fonction de la valeur du flux de neutrons et des dimensions geometriques de l'echantillon, ainsi que les resultats relatifs a la valeur du rendement en isotopes de cesium lors de la fission des noyaux d'uranium. On etudie ensuite les procedes pour assurer l'hermeticite de ces sources. Suit une nomenclature complete des sources produites en URSS, comportant des indications sur leurs dimensions geometriques et sur les valeurs de leur activite. Enfin, il est procede a une comparaison des sources au {sup 60}Co et au {sup 137}Cs. (author) [Spanish] En este informe se describen las principales caracteristicas tecnicas de las fuentes gamma de

  15. Conceptual design of a conveyor system for the Philippine multipurpose cobalt-60 gamma irradiation facility

    International Nuclear Information System (INIS)

    Borras, A.M.

    1992-01-01

    The Multipurpose Cobalt-60 Gamma Irradiation Facility at the PNRI presently utilizes the batch irradiation method using turntables to rotate the product boxes. The target materials or products are being carried manually or with the use of pushcart through the personnel maze. This paper presents a conceptual design for the best suitable product-handling or conveyor system for the Philippine Multipurpose Cobalt-60 Gamma Irradiation Facility. The main irradiation conveyor line shall be a 55 cm x 200 cm slat-type conveyor made of SUS 304 material that could be operated in a semi-batch continuous flow and/or shuffle-dwell method with a tact-time range of 10 min to 7 h. The products can be irradiated in a single direction, two-pass, two-sided method. (auth.). 11 refs.; 4 figs.; 2 tabs

  16. Fetal dose determination in patients with breast cancer submitted to radiotherapy

    International Nuclear Information System (INIS)

    Melo, H.C.; Roesler, I.C.; Leon, E.

    1985-01-01

    The exposure that the fetus receive during radiotherapy treatment for patients with breast cancer submitted to cobalt 60 and linear accelerator of 6 MV is studied. Measurements with a rando-Alderson Phantom and ionization chamber for each individualized irradiation field, at the body level where the fetus is localized during the several stages of pregnancy, are made. (M.A.C.) [pt

  17. Longitudinal diffusion MRI for treatment response assessment: Preliminary experience using an MRI-guided tri-cobalt 60 radiotherapy system.

    Science.gov (United States)

    Yang, Yingli; Cao, Minsong; Sheng, Ke; Gao, Yu; Chen, Allen; Kamrava, Mitch; Lee, Percy; Agazaryan, Nzhde; Lamb, James; Thomas, David; Low, Daniel; Hu, Peng

    2016-03-01

    To demonstrate the preliminary feasibility of a longitudinal diffusion magnetic resonance imaging (MRI) strategy for assessing patient response to radiotherapy at 0.35 T using an MRI-guided radiotherapy system (ViewRay). Six patients (three head and neck cancer, three sarcoma) who underwent fractionated radiotherapy were enrolled in this study. A 2D multislice spin echo single-shot echo planar imaging diffusion pulse sequence was implemented on the ViewRay system and tested in phantom studies. The same pulse sequence was used to acquire longitudinal diffusion data (every 2-5 fractions) on the six patients throughout the entire course of radiotherapy. The reproducibility of the apparent diffusion coefficient (ADC) measurements was assessed using reference regions and the temporal variations of the tumor ADC values were evaluated. In diffusion phantom studies, the ADC values measured on the ViewRay system matched well with reference ADC values with ViewRay MRI. Larger patient cohort studies are warranted to correlate the longitudinal diffusion measurements to patient outcomes. Such an approach may enable response-guided adaptive radiotherapy.

  18. Potentials of radiotherapy in inoperable tumours of the central nervous system in childhood

    International Nuclear Information System (INIS)

    Kocsis, Bela; Horvath, Akos; Varjas, Geza; Bajcsay, Andras; Kaldau, Ferenc; Pap, Lilla

    1990-01-01

    16 patients under 16 years were irradiated because of inoperable tumours in the central nervous system. Irradiations were performed by cobalt-60 facility and by a Neptun 10-p linear accelerator, and the results were evaluated. In these cases radiotherapy has an important role as it is the only definitive therapeutical intervention. Radiotherapy should be attempted even if the histological verification is impossible and only the clinical course referres to malignant process. Radiotherapy must be carried out on the basis of CT scan controlled irradiation plan. The 3-year survival rate was 14 per cent in the authors' material. (author) 16 refs.; 5 figs.; 3 tabs

  19. Computer generation of cobalt-60 single beam dose distribution using an analytical beam model

    International Nuclear Information System (INIS)

    Jayaraman, S.

    1981-01-01

    A beam dose calculation model based on evaluation of tissue air ratios (TAR) and scatter air ratios (SAR) for cobalt-60 beams of rectangular cross section has been developed. Off-central axis fall-off of primary radiation intensity is derived by an empirical formulation involving an arctangent function with the slope of the geometrical penumbra acting as an essential constant. Central axis TAR and SAR values are assessed by semi-empirical polynomial expressions employing the two sides of the rectangular field as the bariables. The model utilises a minimum number of parametric constants and is useful for computer generation of isodose curves. The model is capable of accounting for situations where wedge filters or split field shielding blocks, are encountered. Further it could be widely applied with minor modifications to several makes of the currently available cobalt-60 units. The paper explains the model and shows examples of the results obtained in comparison with the corresponding experimentally determined dose distributions. (orig.) [de

  20. Analysis of Gafchromic EBT3 film calibration irradiated with gamma rays from different systems: Gamma Knife and Cobalt-60 unit.

    Science.gov (United States)

    Najafi, Mohsen; Geraily, Ghazale; Shirazi, Alireza; Esfahani, Mahbod; Teimouri, Javad

    2017-01-01

    In recent years, Gafchromic films are used as an advanced instrument for dosimetry systems. The EBT3 films are a new generation of Gafchromic films. Our main interest is to compare the response of the EBT3 films exposed to gamma rays provided by the Theratron 780C as a conventional radiotherapy system and the Leksell Gamma Knife as a stereotactic radiotherapy system (SRS). Both systems use Cobalt-60 sources, thus using the same energy. However, other factors such as source-to-axis distance, number of sources, dose rate, direction of irradiation, shape of phantom, the field shape of radiation, and different scatter contribution may influence the calibration curve. Calibration curves for the 2 systems were measured and plotted for doses ranging from 0 to 40 Gy at the red and green channels. The best fitting curve was obtained with the Levenberg-Marquardt algorithm. Also, the component of dose uncertainty was obtained for any calibration curve. With the best fitting curve for the EBT3 films, we can use the calibration curve to measure the absolute dose in radiation therapy. Although there is a small deviation between the 2 curves, the p-value at any channel shows no significant difference between the 2 calibration curves. Therefore, the calibration curve for each system can be the same because of minor differences. The results show that with the best fitting curve from measured data, while considering the measurement uncertainties related to them, the EBT3 calibration curve can be used to measure the unknown dose both in SRS and in conventional radiotherapy. Copyright © 2017. Published by Elsevier Inc.

  1. Hypofractionated radiotherapy as local hemostatic agent in advanced cancer

    Directory of Open Access Journals (Sweden)

    Malik Tariq Rasool

    2011-01-01

    Full Text Available Purpose : Tumor bleeding continues to remain a challenge in an oncological setting, and radiotherapy has been studied as a local hemostatic agent. We studied the role of local radiotherapy in controlling bleeding at our center. Materials and Methods : We reviewed 25 treated cases (cancer urinary bladder: 12, lung cancer: 5, cervical cancer: 4, uterine cancer: 1, rectal cancer: 2, schwanoma: 1 at our center from March 2008 to December 2010. All patients had either an advanced or recurrent disease. Radiotherapy schedule was either 20 Gray in 5 fractions or 15 Gray in 5 fractions and was delivered with Cobalt 60. Results and Conclusion : Of 25 patients, 22 (88% responded, and there was complete cessation of bleeding. Both 15 Gray and 20 Gray dose schedule had equal efficacy. Treatment was well tolerated without any intermission. Radiotherapy is a safe and effective option in controlling tumor bleeding.

  2. Cobalt 60 cation exchange with mexican clays

    International Nuclear Information System (INIS)

    Nava Galve, R.G.

    1993-01-01

    Mexican clays can be used to remove radioactive elements from contaminated aqueous solutions. Cation exchange experiments were performed with 60 Co radioactive solution. In the present work the effect of contact time on the sorption of Co 2+ was studied. The contact time in hydrated montmorillonite was from 5 to 120 minutes and in dehydrated montmorillonite 5 to 1400 minutes. The Co 2+ uptake value was, in hydrated montmorillonite, between 0.3 to 0.85 m eq/g and in dehydrated montmorillonite, between 0.6 to 1.40 m eq/g. The experiments were done in a pH 5.1 to 5.7 and normal conditions. XRD patterns were used to characterize the samples. The crystallinity was determined by X-ray Diffraction and it was maintained before and after the cation exchange. DTA thermo grams showed the temperatures of the lost humidity and crystallization water. Finally, was observed that dehydrated montmorillonite adsorb more cobalt than hydrated montmorillonite. (Author)

  3. Effect of cobalt on the growth of Trichoderma viride and determination of its distribution using 60Co

    International Nuclear Information System (INIS)

    Frank, V.; Lesny, J.; Babej, L.

    1993-01-01

    The growth and morphology of filamentous fungus Trichoderma viride grown in the presence of various Co concentrations were studied. Using 60 Co, the cobalt content in mycelium and conidia was determined. No influence of 60 Co-radiation on growth and morphology was observed. (author) 5 refs.; 4 figs

  4. Effect of cobalt-60 irradiation on the developing tooth germ of rat

    Energy Technology Data Exchange (ETDEWEB)

    You, Dong Soo; Lee, Ki Sik [Department of Dental Radiology, Graduate School, Seoul National University, Seoul (Korea, Republic of)

    1976-11-15

    The author observed the effects of the cobalt-60 irradiation on the amelogenesis and dentinogenesis of the albino rat fetuses by means of histological and histochemical methods. Female in oestrus were mated overnight and examined the next morning for evidence of copulation. The lower left abdomen of mothers were exposed to cobalt-60 irradiation on the 10th day of gestation, 100R 200R and 300R respectively. The fetuses were removed from the mothers on the 18th day of gestation. The employed histochemical methods were PAS reaction, colloidal iron reaction, aldehyde fuchsin stain, -amino acid reaction, -SH radical reaction, and methyl green pyronin stain. The results were as follows; 1. The group irradiated by 100R made no histological differences in comparison with the control group. 2. Increasing the irradiation to 200R, abnormal dentin formation occurred, and resulted in enamel hypoplasia, atrophy, and necrosis of odontoblasts. In dentinal papilla, the dilation and the degeneration of the blood vessels, excessive reticular atrophy, and osteodentin were revealed. 3. With the more irradiation (200R-300R), the positive material of PAS, {alpha}-amino acid and aldehyde fuchsin tended to decrease in the ameloblast and in the odontoblast. No significant changes appeared in DNA, the stainability of methylgreen pyronin.

  5. Effect of cobalt-60 irradiation on the developing tooth germ of rat

    International Nuclear Information System (INIS)

    You, Dong Soo; Lee, Ki Sik

    1976-01-01

    The author observed the effects of the cobalt-60 irradiation on the amelogenesis and dentinogenesis of the albino rat fetuses by means of histological and histochemical methods. Female in oestrus were mated overnight and examined the next morning for evidence of copulation. The lower left abdomen of mothers were exposed to cobalt-60 irradiation on the 10th day of gestation, 100R 200R and 300R respectively. The fetuses were removed from the mothers on the 18th day of gestation. The employed histochemical methods were PAS reaction, colloidal iron reaction, aldehyde fuchsin stain, -amino acid reaction, -SH radical reaction, and methyl green pyronin stain. The results were as follows; 1. The group irradiated by 100R made no histological differences in comparison with the control group. 2. Increasing the irradiation to 200R, abnormal dentin formation occurred, and resulted in enamel hypoplasia, atrophy, and necrosis of odontoblasts. In dentinal papilla, the dilation and the degeneration of the blood vessels, excessive reticular atrophy, and osteodentin were revealed. 3. With the more irradiation (200R-300R), the positive material of PAS, α-amino acid and aldehyde fuchsin tended to decrease in the ameloblast and in the odontoblast. No significant changes appeared in DNA, the stainability of methylgreen pyronin.

  6. Physical aspects of quality assurance in cobalt teletherapy units

    Energy Technology Data Exchange (ETDEWEB)

    Ng, Kwan Hong [Malaya Univ., Kuala Lumpur (Malaysia)

    1989-06-01

    ICRU Report No. 24 states that +- 5% is a reasonable degree of accuracy to strive for in the delivery of absorbed doses to target volumes in radiotherapy. To achieve this quality assurance level, a comprehensive programme comprising both physical and clinical components is needed. The purpose of this paper is to present the rationale and guidelines for implementing a recommended quality assurance programme. It will emphasize the physical aspects pertaining to acceptance and constancy tests using Cobalt-60 teletherapy units. It will also outline a suggested schedule of quality assurance testings including radiation dosimetry, geometry and electrochemical safety. (author).

  7. Feasibility Study for Cobalt Bundle Loading to CANDU Reactor Core

    International Nuclear Information System (INIS)

    Park, Donghwan; Kim, Youngae; Kim, Sungmin

    2016-01-01

    CANDU units are generally used to produce cobalt-60 at Bruce and Point Lepreau in Canada and Embalse in Argentina. China has started production of cobalt-60 using its CANDU 6 Qinshan Phase III nuclear power plant in 2009. For cobalt-60 production, the reactor’s full complement of stainless steel adjusters is replaced with neutronically equivalent cobalt-59 adjusters, which are essentially invisible to reactor operation. With its very high neutron flux and optimized fuel burn-up, the CANDU has a very high cobalt-60 production rate in a relatively short time. This makes CANDU an excellent vehicle for bulk cobalt-60 production. Several studies have been performed to produce cobalt-60 using adjuster rod at Wolsong nuclear power plant. This study proposed new concept for producing cobalt-60 and performed the feasibility study. Bundle typed cobalt loading concept is proposed and evaluated the feasibility to fuel management without physics and system design change. The requirement to load cobalt bundle to the core was considered and several channels are nominated. The production of cobalt-60 source is very depend on the flux level and burnup directly. But the neutron absorption characteristic of cobalt bundle is too high, so optimizing design study is needed in the future

  8. Feasibility Study for Cobalt Bundle Loading to CANDU Reactor Core

    Energy Technology Data Exchange (ETDEWEB)

    Park, Donghwan; Kim, Youngae; Kim, Sungmin [KHNP Central Research Institute, Daejeon (Korea, Republic of)

    2016-10-15

    CANDU units are generally used to produce cobalt-60 at Bruce and Point Lepreau in Canada and Embalse in Argentina. China has started production of cobalt-60 using its CANDU 6 Qinshan Phase III nuclear power plant in 2009. For cobalt-60 production, the reactor’s full complement of stainless steel adjusters is replaced with neutronically equivalent cobalt-59 adjusters, which are essentially invisible to reactor operation. With its very high neutron flux and optimized fuel burn-up, the CANDU has a very high cobalt-60 production rate in a relatively short time. This makes CANDU an excellent vehicle for bulk cobalt-60 production. Several studies have been performed to produce cobalt-60 using adjuster rod at Wolsong nuclear power plant. This study proposed new concept for producing cobalt-60 and performed the feasibility study. Bundle typed cobalt loading concept is proposed and evaluated the feasibility to fuel management without physics and system design change. The requirement to load cobalt bundle to the core was considered and several channels are nominated. The production of cobalt-60 source is very depend on the flux level and burnup directly. But the neutron absorption characteristic of cobalt bundle is too high, so optimizing design study is needed in the future.

  9. Protection of patient In radiotherapy

    International Nuclear Information System (INIS)

    Deiyi, P.

    2013-04-01

    The purpose of this project is to clarify some aspects about protection of patient in radiotherapy. Therefore, some basic information about how the use of ionizing radiation in medicine has brought tremendous health benefits to the population globally, the requirement of radiation protection (Justification of practices, Dose limitation and Optimization of protection), and the deterministic and stochastic effects of radiation are presented. The aim of radiotherapy is to use ionizing radiation to cure diseases or make the symptoms of a disease less severe. Also presented are layout of a radiotherapy facility (controlled areas, supervised areas, mazes, door and interlocks, patient observation and communication, and warning sign and lights), radionuclides commonly used for radiation therapy and their main emissions, equipment and devices used in radiotherapy, aspect of protection of patient in radiotherapy such as: leakage test, source on/off, emergency buttons, radiation oncology team, treatment planning, room monitoring, equipment or for protection and Cobalt-60 unit stuck source. The advantages of brachytherapy, leakage from the treatment head and radiation incidents resulting from incorrect dose calibration are discussed. The importance of minimization dose exposure, by considering the basic principles of: time, distance and shielding are also stated. These principles prevent deterministic effects and limit stochastic effects of radiation. (author)

  10. Dosimetric evaluation of Radiotherapy units wit {sup 60}Co; Evaluacion dosimetrica de unidades de radioterapia con {sup 60}Co

    Energy Technology Data Exchange (ETDEWEB)

    Leon, B. Salinas de; Tovar M, V.; Becerril V, A. [Instituto Nacional de Investigaciones Nucleares, A.P. 18-1027, 11801 Mexico D.F. (Mexico)

    2000-07-01

    The SSDL network of the IAEA performs, every year, quality audit tests for radiotherapy services ({sup 60} Co units and linear accelerators), and for national SSDL as well. Because of the SSDL-Mexico results in these tests and due to our enthusiasm and confidence in our work, a parallel test has been done , which is described in this talk as well as the results. Nowadays, a second parallel test goes up, which could confirm our optimism and open the possibility to our country to start a national dosimetric audit of {sup 60} Co radiotherapy units. (Author)

  11. Therapeutic results in ovarian cancer after replacement of conventional radiotherapy by Co-60 irradiation

    International Nuclear Information System (INIS)

    Kucera, H.; Szalay, St.; Weghaupt, K.; Heckenthaler, W.; Vienna Univ.

    1981-01-01

    The use of Co-60 screen and pendular irradiation instead of conventional radiotherapy has brought about an improvement in the 5-year survival rate in patients with more advanced stages of ovarian cancer. Although the general side effects of Co-60 irradiation are considered to be more unpleasant than those of X-ray and radium therapy, severe, reversible or irreversible damage to the urogenital tract and intestinal organs was diminished by accurate planning of Co-60 therapy, so that these complications occurred less frequently than with conventional radiotherapy. (author)

  12. Single institutional retrospective analysis: treatment of choroidal melanomas with cobalt-60 brachytherapy Análise retrospectiva uni-institucional: tratamento de melanomas de coróide com braquiterapia utilizando cobalto-60

    Directory of Open Access Journals (Sweden)

    Antônio Cássio Assis Pellizzon

    2004-06-01

    Full Text Available PURPOSE: To evaluate the outcome of patients with choroidal melanoma treated with conservative therapy with brachytherapy (episcleral Co-60 plaque therapy at the "Hospital do Cancer" São Paulo, Brazil. METHODS: We evaluated 102 patients consecutively treated from January, 1999 to June, 1999. Median age, maximum tumor base diameter and apex size were 55.5 years, 9.75 mm and 5 mm, respectively. Doses at the base of the tumor, including 1 mm of sclera, ranged from 157 to 487 Gy (median 284.5 Gy and to the apex from 37 to 220 Gy (median 106 Gy. RESULTS: The crude eye preservation rate with conservative therapy alone was 78.5%. Five-year overall actuarial survival rate was 92.2% and eye conservation rate was 78%. Side effects were mostly an uncomplicated retinopathy in 39/102 patients (38.2%; macular degeneration or scarring led to poor central vision in 31/102 patients (30.3% of cases. CONCLUSION: Our experience with cobalt-60 plaque brachytherapy achieved a satisfactory rate of local tumor control, despite the oversized base diameters of treated tumors.OBJETIVOS: Para avaliar o resultado de tratamento pacientes portadores de melanoma de coróide tratados com braquiterapia (placas episclerais de Co-60 no Hospital do Câncer, São Paulo, Brasil. MÉTODOS: Foram avaliados 108 pacientes tratados consecutivamente de janeiro de 1995 a junho de 1999, com idade mediana de 55,5 anos, diâmetro da base do tumor e altura máximos 9,75 mm e 5 mm, respectivamente. As doses na base do tumor, incluindo 1 mm de esclera variaram de 157 a 487 Gy (mediana 284,5 Gy e para o ápice de 37 até 220 Gy (mediana 106 Gy. RESULTADOS: A taxa de preservação ocular foi 78,5%, com sobrevida atuarial global em cinco anos, e a taxa de conservação ocular atuarial foram 92,2% e 78%, respectivamente. Os principais efeitos colaterais relacionados ao tratamento foram retinopatia em 39/102 (38,2% pacientes e degeneração macular, levando a déficit visual central em 31/102 (30

  13. Status of Radiotherapy around the World: Radiotherapy in China. Chapter 25.6

    International Nuclear Information System (INIS)

    Zhu, Ci; Yin, Wei Bo; Chen, Bo; Zhang, Chun Li; Zhang, Hong Zhi; Li, Ye Xiong

    2017-01-01

    China’s experience of using radiotherapy to treat cancer began with the installation of the first superficial X ray machine at Peking Union Medical College Hospital in early 1920, followed by the first 200 kV deep X ray machine installed at the French Hospital in Shanghai in 1923, and the first Chinese radiotherapy department established at the Affiliated Hospital of Peking University in 1932. However, the field of radiotherapy in China was still in its infancy between the 1930s and 1960s, as all operating machines were imported from foreign countries, making radiotherapy very difficult to access for cancer patients. Progress was slow until the mid-1970s, when the first batch of megavoltage machines (cobalt-60 machines and linacs) was produced by Chinese manufacturers. Owing to the efforts of radiotherapy pioneers such as Wu Huanxing, Gu Xianzhi, Liu Taifu, and Yin Weibo, who brought radiotherapy to China and shaped how Chinese patients would be treated today, radiotherapy was installed as one of the mainstream modalities of cancer treatment. In 1986, the China Society for Radiation Oncology (CSTRO) was founded, indicating that a network advancing radiation oncology practice in China was taking shape. One year later, the first issue of the Chinese Journal of Radiation Oncology was published, offering a platform for the timely exchange and sharing of laboratory and clinical research outcomes among radiation oncology professions across the country. During the past two decades, with the introduction of the gamma knife and stereotactic radiotherapy, 3-D conformal radiotherapy, IMRT, IGRT and other advanced techniques, China experienced not only a big jump in its radiotherapy equipment and facilities, but also a dramatic growth in the excellence of radiation oncology specialist staff nationwide

  14. Comparison of skin doses to large fields using tangential beams from cobalt-60 gamma rays and 4-MV x rays

    International Nuclear Information System (INIS)

    Gagnon, W.F.; Peterson, M.D.

    1978-01-01

    Excess radiation to the skin during external beam megavoltage radiation therapy has reportedly caused excessive erythema in patients treated with the Clinac 4 linear accelerator on sloping surfaces, but not for similar treatments with cobalt-60. Doses at the epidermal level were measured under geometries simulating sloping surfaces for a Clinac 4 and an Eldorado 8 cobalt-60 teletherapy machine. For equal doses to the axilla, doses to the epidermal layer were similar. When the tumor dose was calculated for the mediastinum, the dose to the skin in the axillary region was 12% higher for the Clinac 4

  15. SSDL Argentina: Dosimetric intercomparison programme for cobalt 60 therapy units

    Energy Technology Data Exchange (ETDEWEB)

    Saravi, M; Papadopulos, S; Mugliaroli, H [Comision Nacional de Energia Atomica, Buenos Aires (Argentina)

    1996-08-01

    Thermoluminescence dosimeters (TLD) are widely used to verify absorbed dose delivered from radiation therapy beams. The Secondary Standard Dosimetry Laboratory (SSDL) of Argentina uses TLD for its mailed dose intercomparison programme for cobalt 60 radiation therapy units. Results obtained since 1978 as well as causes of dose discrepancies greater than 5% are analyzed. Results of the external quality control performed by the IAEA for this programme indicate that the dose evaluated by the SSDL TLD service for the participating centers is about 1% lower than that evaluated by the IAEA TLD service. This deviation is accepted taking on account that a {+-} 2% dose uncertainty for TLD dosimetry is reasonable. (author). 5 refs, 5 figs, 2 tabs.

  16. An economic benefit analysis on the cobalt-60 irradiation facility of Beijing Radiation Research Center

    International Nuclear Information System (INIS)

    Wang Binlin

    1995-01-01

    The peculiarity, the investment and annual operating cost of the 3.7 x 10 16 Bq (MCi) cobalt-60 irradiation facility at Beijing Radiation Application Research Centre are described. Its economic benefits each year are analyzed according to several year operating practice. Some related questions on carrying out radiation processing are raised and discussed. (author)

  17. Separation of iron and cobalt using 59Fe and 60Co by dialysis of polyvinylpyrrolidone-metal complexes: A greener approach

    International Nuclear Information System (INIS)

    Lahiri, Susanta; Sarkar, Soumi

    2007-01-01

    An environmentally benign method to separate iron and cobalt has been developed using a safe chemical, polyvinylpyrrolidone (PVP). The method involves dialysis of PVP-Fe and PVP-Co complexes against triple-distilled water. 59 Fe and 60 Co were used as radioactive tracers of iron and cobalt throughout the experiment. No other chemicals are required for clean separation of cobalt from iron. The optimum condition for separation has been obtained at pH 5 using 10% aqueous solution of PVP. The method is applicable from trace scale to macro-scale. Very high separation factors have been obtained

  18. Determination of C0-60 in Cobalt Slugs and Slabs and Radionuclides in Curium Sampler Slugs L-Reactor Disassembly Basin

    International Nuclear Information System (INIS)

    Casella, V.R.

    2004-01-01

    Co-60 was historically produced in the SRS reactors. Cobalt slugs were irradiated in the early 1970s. Post-production, remaining cobalt slugs (including slab form) were consolidated for storage. There are approximately nine hundred cobalt slugs currently stored awaiting final disposition. These slugs had historically incomplete documentation for activity rates; therefore, assaying was required in order to determine their activity levels. Since the gamma dose rate from these slugs is extremely high, the most cost effective way to shield a source of this magnitude from personnel and the radiation detector was to use the basin water in which the slugs are stored as the shield. A sodium iodide gamma detector was placed above a specially designed air collimator assembly, so that slug was at least eight feet from the detector and was shielded by the basin water. Using a sodium iodide detector and multichannel analyzer system and an underwater collimator assembly, Co-60 concentrations we re determined for Disassembly Basin cobalt slugs and slabs and 18 curium sampler slugs. The total activity of all of the assayed slugs summed to 31,783 curies. From the Co-60 concentrations of the curium sampler slugs, the irradiation flux was determined for the known irradiation time. The amounts of Pu-238, 239, 240, 241, 242; Am-241, 243; and Cm-242, 244 produced were then obtained based on the original amount of Pu-239 irradiated

  19. Transfer of Cobalt-60 to plants from soils treated with sewage sludge

    International Nuclear Information System (INIS)

    Grummitt, W.E.

    1976-01-01

    The uptake of 60 Co from soils fertilized with contaminated sewage sludge has been investigated under a variety of experimental conditions. A number of garden plots were prepared by thoroughly mixing sludge containing 60 Co with farm soils from the Ottawa Valley. Edible plants were grown in the open on these plots under conditions approximating those in market gardens. The crops were harvested at maturity and were prepared for measurement of 60 Co by drying portions of the roots, leaves, stems and fruit. The samples were counted on a large germanium detector which was capable of resolving 60 Co from other gamma-emitting nuclides. Cobalt was readily taken up from contaminated sludge but was nonuniformly distributed in various parts of the plant. In general, the roots showed the highest levels while edible portions such as seeds and tubers had much lower concentrations. The uptake ratio, expressed as radioactivity in the sample to radioactivity in the soil, varied from 0.003 to 8 on a dry-weight basis. (author)

  20. Results of postoperative radiotherapy and radiation of recurrent tumours, observed in adenomas of the pituitary gland operated at a primary stage

    International Nuclear Information System (INIS)

    Oettle, E.

    1987-01-01

    This retrospective study included 134 patients showing adenomas of the pituitary gland. It was found that radiotherapy carried out immediately after surgery was superior to radiation commencing only after tumour recidivation. Treatment was predominantly based an 'ultrahard' X-rays (betatron), to a lesser extent on cobalt-60 gamma rays. (MBC) [de

  1. Primary radiotherapy of prolactinomas. Eight- to 15-year follow-up

    Energy Technology Data Exchange (ETDEWEB)

    Mehta, A.E.; Reyes, F.I.; Faiman, C.

    1987-07-01

    Eight women with amenorrhea, galactorrhea, and hyperprolactinemia, of whom six had macroadenomas and two had microadenomas, were treated with conventional (cobalt-60) external radiotherapy, and their progress was monitored for eight to 15 years. Normoprolactinemia was established in five of these patients after two to 13 years (median, nine years). A recurrence was treated surgically in one patient, and stable prolactin values and roentgenographic features have been maintained in two patients. Hypopituitarism has developed in only one patient to date, and no other complications of radiotherapy have been observed. These findings, together with the few previous reports on the long-term effects of radiotherapy on macroprolactinomas, have been compared with the long-term results following surgery or dopamine agonist therapy. The normalization of prolactin values is considerably delayed following radiotherapy compared with the other two therapeutic modalities. However, radiotherapy affords permanent normalization without recurrence in a larger percentage of patients than does surgery and avoids the considerable ongoing cost and inconvenience of daily drug ingestion. The long-term development of hypopituitarism appears to be an acceptably small risk of radiotherapy. Thus, conventional radiotherapy is an attractive treatment option, particularly for macroprolactinomas; adjunctive bromocriptine can be used while awaiting the longer-term benefits of radiotherapy.

  2. Primary radiotherapy of prolactinomas. Eight- to 15-year follow-up

    International Nuclear Information System (INIS)

    Mehta, A.E.; Reyes, F.I.; Faiman, C.

    1987-01-01

    Eight women with amenorrhea, galactorrhea, and hyperprolactinemia, of whom six had macroadenomas and two had microadenomas, were treated with conventional (cobalt-60) external radiotherapy, and their progress was monitored for eight to 15 years. Normoprolactinemia was established in five of these patients after two to 13 years (median, nine years). A recurrence was treated surgically in one patient, and stable prolactin values and roentgenographic features have been maintained in two patients. Hypopituitarism has developed in only one patient to date, and no other complications of radiotherapy have been observed. These findings, together with the few previous reports on the long-term effects of radiotherapy on macroprolactinomas, have been compared with the long-term results following surgery or dopamine agonist therapy. The normalization of prolactin values is considerably delayed following radiotherapy compared with the other two therapeutic modalities. However, radiotherapy affords permanent normalization without recurrence in a larger percentage of patients than does surgery and avoids the considerable ongoing cost and inconvenience of daily drug ingestion. The long-term development of hypopituitarism appears to be an acceptably small risk of radiotherapy. Thus, conventional radiotherapy is an attractive treatment option, particularly for macroprolactinomas; adjunctive bromocriptine can be used while awaiting the longer-term benefits of radiotherapy

  3. Measurement for cobalt target activity and its axial distribution

    International Nuclear Information System (INIS)

    Li Xingyuan; Chen Zigen.

    1985-01-01

    Cobalt target activity and its axial distribution are measured in process of producing radioactive isotopes 60 Co by irradiation in HFETR. Cobalt target activity is obtained with measured data at 3.60 m and 4.60 m, relative axial distribution of cobalt target activity is obtained with one at 30 cm, and axial distribution of cobalt target activity(or specific activity) is obtained with both of data. The difference between this specific activity and measured result for 60 Co teletherapy sources in the end is less than +- 5%

  4. Radiotherapy and skin tumors; Radiotherapie et tumeurs curanees

    Energy Technology Data Exchange (ETDEWEB)

    Calitchi, E.; KIrova, Y.; Le bourgeois, J.P. [Hopital Henri-Mondor, 94 - Creteil (France)

    1998-09-01

    Radiotherapy plays an important role in treatment of skin tumours. For skin carcinomas, external irradiation (kilo-voltage X-rays or electrons according to clinical characteristics) is more valuable than interstitial brachytherapy, which is recommended for tumours of the lip and of the nasal vestibule. In mycosis fungoides, total cutaneous electron beam radiation therapy is efficient for patients with limited superficial plaques. In the classical form of Kaposi`s sarcoma, radiotherapy can achieve local control-whereas it obtains good palliative results in the epidemic form. (author)

  5. Effect of the gamma radiation of cobalt 60 on the beta carotids present in the carrot

    International Nuclear Information System (INIS)

    Perez Lopez, Sergio Victor Hugo

    1997-01-01

    In the present work it was investigated the effect of the gamma radiation of cobalt 60 on the beta carotid's in the carrot (daucus carota), using for it three different radiation dose (100, 150 and 200 kilo-rad) and analyzing them by means of the liquid chromatography technique of high resolution (HPLC)

  6. Evaluation of Radiosensitivity of HeLa Cells Infected with Polio Virus Irradiated by Co 60

    Directory of Open Access Journals (Sweden)

    F Seif

    2008-04-01

    Full Text Available ABSTRACT: Introduction & Objective: The main purpose of radiotherapy is exposing enough doses of radiation to tumor tissue and protecting the normal tissues around it. Tumor dose for each session in radiotherapy will be considered based on radiosensitivity of the tissues. The presence of viral diseases in tumoral area can affect the radiosensitivity of cells. This study aimed to evaluate the radiosensitivity of Hela cells infected with poliomyelitis virus irradiated by Co 60. Materials & Methods: In this study, the radiosensitivity of HeLa cells, with or without the viral infection, after gamma radiation of cobalt 60, was assessed. Results: Results of comparison of the radisensitivity of infected and uninfected cells indicates that after 2 Gy irradiation by Co 60, polio infection in low, moderate and high virus load, increases the cell death by 20-30%, 30-40% and 70-90% respectively. Conclusion : Radiosensitivity of tumoral cells increase when they are infected with viral agents. Results of this study showed that non cancer diseases should be considered when prescribing dose fraction in radiotherapy of cancers.

  7. Brachytherapy with cobalt plaques in the conservative treatment of intraocular tumors. The hospital A.C. camargo experience

    International Nuclear Information System (INIS)

    Trippe, N.; Novaes, P.E.R.S.; Ferrigno, R.; Pellizzon, A.C.; Fogarolli, R.C.; Maia, M.A.C.; Salvajoli, J.V.; Baraldi, H.E.; Chojniak, M.M.; Erwene, CM

    1996-01-01

    From December 1989 to December 1993, 76 cases of intraocular tumors, including 56 adult patients with uveal melanomas and 20 children with retinoblastoma, were treated with exclusive intraocular brachytherapy with Cobalt plaques. The goal was to keep the vision function and at same time not compromising the chance of cure. The dose prescribed was 40Gy, calculated at the apex of the lesion for retinoblastomas and 100 to 120Gy for uveal melanomas. With the minimum follow up of 24 months, of the 56 patients with uveal melanomas, 41 (73,3%) had their vision preserved and 15 (26,4%) had local failure and were underwent enucleation. With the medium follow up of 27 months, 17 (85,5%) of the patients with retinoblastoma had their vision preserved, while 3 (15%) had local failure and were treated by enucleation. The grade I and II complications occurred in 9 (42,8%) patients and 100% of them are with no evidence of systemic disease. When well indicated, the conservative treatment of intraocular tumors with brachytherapy is a good alternative to enucleation and must be done by a multidisciplinary and well trained medical professional group

  8. Spontaneous carotid-cavernous sinus fistula disappeared following cobalt 60 irradiation. Case report

    Energy Technology Data Exchange (ETDEWEB)

    Satoh, Toru; Yamamoto, Yuji; Asari, Syoji (Matsuyama Shimin Hospital, Ehime (Japan))

    1983-12-01

    The authors reported a case of spontaneous carotid-cavernous sinus fistula fed by meningohypophyseal trunk of the internal carotid artery, that completely disappeared following cobalt 60 irradiation to the region of fistula (27 days; total dose, 4,100 rad). A 65-year-old man was admitted to our hospital on May 25, 1982, with a two-week history of progressive prominence of the left eye, diplopia on left lateral gaze, and continuous intracranial bruit. He first noted redness of the left eye without apparent cause such as head trauma. On admission, slight nonpulsative exophthalmos, periorbital edema, chemosis, and venous congestion of the conjunctiva of the left eye were noted. The pupils were reactive and equal in size, and the left abducent nerve palsy was observed. Fundoscopic examination disclosed to be normal. No bruit was heard over the left orbital region. Left carotid angiography on May 28 demonstrated dural internal carotid-cavernous sinus fistula fed by meningohypophyseal trunk, and drained into superior and inferior ophthalmic veins and basilar venous plexus. Though the patient was treated only conservatively, symptoms became worse to decrease visual acuity. On July 14, we started cobalt 60 irradiation to the region of fistula (27 days; total dose 4,100 rad). Symptoms gradually improved about halfway through irradiation. After completion of irradiation, almost complete improvement of visual and ocular symptoms was observed except the left abducent nerve palsy. Repeated angiography on Aug. 20 revealed complete disappearance of fistula. Three months after treatment, no recurrence of symptoms was observed and the abducent nerve palsy persisted without improvement.

  9. Experimental investigation of cobalt-60 accumulation and elimination in Cyprinus carpio (L.)

    International Nuclear Information System (INIS)

    Fritsch, A.F.

    1985-11-01

    When introduced in cation form, 60 Co showed a distinct tendency to form anion or neutral complexes (50% and 20%, respectively); this was favorized by a high biomass content per liter of water. The ionic evolution of the radionuclide did not affect its accumulation level in the fish. Direct contamination predominated (70%) and the concentration factor at equilibrium was 10. Nutritional transfer from Limnaea to carp, after ingestion of 45 contaminated rations in 63 days, resulted in a low radionuclide retention factor (3 x 10 -3 ) that was not subject to bioamplification. Cobalt-60 was primarily eliminated via urine (60%), while the fecal matter contained only 20% of the radioactive isotope ingested in the food. The 60 Co content of carp contaminated from the water increased proportionally with the temperature. However, the 60 Co concentration did not vary significantly with the thermal factor, and the radionuclide concentration factor ranged from 4 to 6 between 8 0 C and 25 0 C. Decontamination was generally a two-phase process characterized by a short biological half-life ( 60 Co contained in the fish. The high 60 Co content of the digestive tract may be explained by fecal excretion of the radioactive isotope (30-40% of the elimination). The kidneys act as radionuclide elimination regulators via the urinary system [fr

  10. Accumulation of cobalt by cephalopods

    International Nuclear Information System (INIS)

    Nakahara, Motokazu

    1981-01-01

    Accumulation of cobalt by cephalopod mollusca was investigated by radiotracer experiments and elemental analysis. In the radiotracer experiments, Octopus vulgaris took up cobalt-60 from seawater fairly well and the concentration of the nuclide in whole body attained about 150 times the level of seawater at 25th day at 20 0 C. Among the tissues and organs measured, branchial heart which is the specific organ of cephalopods showed the highest affinity for the nuclide. The organ accumulated about 50% of the radioactivity in whole body in spite of its little mass as 0.2% of total body weight. On the other hand, more than 90% of the radioactivity taken up from food (soft parts of Gomphina melanaegis labelled with cobalt-60 previously in an aquarium) was accumulated in liver at 3rd day after the single administration and then the radioactivity in the liver seemed to be distributed to other organs and tissues. The characteristic elution profiles of cobalt-60 was observed for each of the organs and tissues in Sephadex gel-filtration experiment. It was confirmed by the gel-filtration that most of cobalt-60 in the branchial heart was combined with the constituents of low molecular weights. The average concentration of stable cobalt in muscle of several species of cephalopods was 5.3 +- 3.0 μg/kg wet and it was almost comparable to the fish muscle. On the basis of soft parts, concentration of the nuclide closed association among bivalve, gastropod and cephalopod except squid that gave lower values than the others. (author)

  11. Cobalt-60 gamma radiation effects on degradation of pesticides used in stored rice and beans

    International Nuclear Information System (INIS)

    Groppo, Gerson A.

    1988-02-01

    The present work, carried out at CENA, an agriculture nuclear energy center - University of Sao Paulo - Brazil, investigates the Cobalt-60 gamma radiation effects on insecticides applied to stored rice and beans. The radiation dose applied - 200 Gy - to the stored rice and beans treated with insecticides was not sufficient to cause a noticeable chemical degradation through insect mortality. (author). 31 refs., 23 tabs

  12. Differential gene expression in primary fibroblasts induced by proton and cobalt-60 beam irradiation

    DEFF Research Database (Denmark)

    Nielsen, Steffen; Bassler, Niels; Grzanka, Leszek

    2017-01-01

    profile: entrance, mid-SOBP and at the SOBP distal edge. Dose was delivered in three fractions × 3.5 Gy(RBE) (RBE 1.1). Cobalt-60 (Co-60) irradiation was used as reference. Real-time qPCR was performed to determine gene expression levels for 17 genes associated with inflammation response, fibrosis...... and angiogenesis. RESULTS: Differences in median gene expression levels were observed for multiple genes such as IL6, IL8 and CXCL12. Median IL6 expression was 30%, 24% and 47% lower in entrance, mid-SOBP and SOBP distal edge groups than in Co-60 irradiated cells. No genes were found to be oppositely regulated...... fibroblast cultures. Inflammatory factors were generally less extensively upregulated by proton irradiation compared with Co-60 photon irradiation. These effects may possibly influence the development of normal tissue damage in patients treated with proton beam therapy....

  13. Effects of cobalt-60 ionizing radiation on human erythrocyte and its membrane proteins

    International Nuclear Information System (INIS)

    Amancio, Francisco Fernandes

    1998-01-01

    Ionizing radiation has several uses, as sterilization and radiotherapy, by its effects on living beings. recently, it has been used, at relatively lower doses (25 Gy), on blood for transfusions, mainly to eliminate undesirable graft host reactions, for use in multi transfused or immunocompromised patients. Here, we study the effect of larger doses of cobalt-60 ionizing radiation (25-1600 Gy) on human erythrocytes, by cytometric, physiologic, biochemical and immunological methods, looking for its effects and its detection. The red cells presented a clear dose-dependent increase in this volume, when irradiated in doses higher than 200 Gy, more significant in stored blood, but without hemolysis. Osmotic fragility was increased only after irradiation of more than 400 Gy. By ektacytometry, there was a lower deformability of irradiated red cells, at low stress (0.3 Pa), similar to capillary flow, but without alteration in higher stress (3 Pa), found in cardiac chambers. By SDS-PAGE, it was demonstrated that irradiated isolated erythrocyte membranes had aggregation of spectrin molecules, and decay of bands with lower molecular mass. This effect could be attributed to the radiation-induced hydroxyl radical, by specific scavenger studies. Those modifications were both antigenic and immunogenic in experimental animals, and the induced antibodies recognizes, by ELISA and immunoblot, both native or irradiated membrane proteins. They recognize rather irradiated whole erythrocyte than native ones, by hemagglutination, indirect immunofluorescence or flow cytometry assays. Our data suggests that human red cells could be irradiated at higher doses than those usually employed, with possible effect on other contaminant pathogens, without loss of viability of its use in transfusions. After improvements, irradiation induced epitopes detection could be a new tool in biological dosimetry. (author)

  14. Development of a new model of actinic enteritis in rats using a cobalt-60 open source and a protection device as a collimator

    Energy Technology Data Exchange (ETDEWEB)

    Nunes, Vinicius Rodrigues Taranto; Vidigal, Paula Vieira Teixeira; Barbuto, Rafael Calvao; Duval-Araujo, Ivana, E-mail: vivas1912@hotmail.com [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte (UFMG), MG (Brazil); Pereira, Marcio Tadeu; Ladeira, Luis Carlos Duarte [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil)

    2017-03-15

    Purpose: To describe a new model of actinic enteritis that does not use radiotherapy machines. Methods: Sixteen Wistar rats were divided into four groups, consisting of four animals each: control (group A), two weeks after irradiation (group B), five weeks after irradiation (group C) and eight weeks after irradiation (group D). Animals were given a 10Gy radiation from a Cobalt-60 natural source in a nuclear technology research center. Protections of the surrounding tissues were obtained through the usage of plumb devices with a hole in the center, which served as a collimator. We obtained irradiated and non-irradiated colons from each animal. Results: In group B we found an important inflammatory response in the irradiated colon, which appeared in a reduced way in group C and was minimal in group D, in which we found a relevant collagen submucosal deposition/fibrosis. In all groups, the non-irradiated colon had a lower pathological damage in comparison with the irradiated colon. Conclusion: We thus described an efficient and feasible technique for obtaining an animal model of actinic enteritis. (author)

  15. Study on the possibility of using a 60 Co therapeutical unity in Intensity Modulated Radiotherapy (IMRT)

    International Nuclear Information System (INIS)

    Dantas, Samuel Cesar

    2009-06-01

    With the increasing advances in complex treatment techniques, there is a tendency to obtain more sophisticated equipment to deliver the dose. The use of 3D conformal radiotherapy is now routine in many radiotherapy facilities as well as the utilization of intensity modulated radiotherapy (IMRT). Both are usually implemented using linear accelerators equipped with multi leaves collimators, which create the conformity and the fluence distributions required. However, the complexity of increasingly sophisticated equipment, such as linear accelerators, requires a frequent quality control of their operation, as well as a detailed and constant maintenance. Even carrying out these procedures, the accelerators may present technical problems interrupting for a long time a treatment using the IMRT technique. Despite the clear practical and technological advantages that linear accelerators have on 60 Co irradiators, these devices occupy an important place in radiotherapy, mainly due to the low cost of equipment installation and maintenance when compared to those required by accelerators. Many radiotherapy facilities that work with IMRT have tele therapeutic isocentric 60 Co units. In principle, such equipment would be able to be used for treatment with IMRT using compensating blocks to modulate the beam. This study investigates this possibility and shows that it is feasible. The comparison of treatment plans of a head-and-neck cancer and other of a cancer of the central nervous system, based on a 60 Co irradiator and a Linac 2300 C/D, presented advantages for the 60 Co irradiator. Furthermore; the delivery of dose obtained with the two systems showed themselves equivalent when compared to their respective plans. (author)

  16. Immunological assessment of mice hyperimmunized with native and Cobalt-60-irradiated Bothrops venoms

    International Nuclear Information System (INIS)

    Ferreira Junior, R.S.; Meira, D.A.; Martinez, J.C.

    2005-01-01

    ELISA was used to evaluate, accompany, and compare the humoral immune response of Swiss mice during hyperimmunization with native and Cobalt-60-irradiated ( 60 Co) venoms of Bothrops jararaca, Bothrops jararacussu and Bothrops moojeni. Potency and neutralization were evaluated by in vitro challenges. After hyperimmunization, immunity was observed by in vivo challenge, and the side effects were assessed. The animals immunization with one LD50 of each venom occurred on days 1, 15, 21, 30, and 45, when blood samples were collected; challenges happened on the 60th day. Results showed that ELISA was efficient in evaluating, accompanying and comparing mouse immune response during hyperimmunization. Serum titers produced with natural venom were similar to those produced with irradiated venom. Immunogenic capacity was maintained after 60 Co-irradiation. The sera produced with native venom showed neutralizing potency and capacity similar to those of the sera produced with irradiated venom. All antibodies were able to neutralize five LD50 from these venoms. Clinical alterations were minimum during hyperimmunization with irradiated venom, however, necrosis and death occurred in animals inoculated with native venom. (author)

  17. Introduction dosimetric data of cobalt-60 unit in planning new Win-PTL- 3D

    International Nuclear Information System (INIS)

    Gonzalez Perez, Yelina; Rodriguez Zayas, Michael; Perez Guevara, Adrian; Sanchez Zamora, Luis; Reyes Gonzalez, Tommy; Sola Rodriguez, Yeline; Caballero, Roberto; Cruz Marcane, Viviana

    2009-01-01

    3D planning is based on the individual and image reconstruction formation of fields, allowing better absorption of dose volume White minimizing damage to surrounding healthy tissue. During the clinical implementation of the Win-PLT software includes validation from the implementation of dosimetric acceptance tests through a series of precise experimental measurements, reflecting different clinical situations (test cases). For the commissioning characterized the photon beam Cobalt Unit 60, taking measurements with a set consisting of a phantom dosimetric automatic ionization chambers and electrometer Tandem. The measured data are used to power the TPS through WINCOM auxiliary program that lets you adjust a number of parameters to model the photon beam. This adjustment is made by comparing the PDD curves and profiles of experimental data with modeled data. The test cases performed are in compliance with the requirements proposed in the geometric of the AAPM TG55. The modeling of beam dosimetry data was successful, since the discrepancies were within the criteria TRS-430. The cases involved events where points near the edge of the field and in the presence of blocking a discrepancy outside the tolerance, suggesting not to use these items for purposes of limitation. Win TPS-PLT is suitable for clinical use with the photon beam Cobalt Unit 60, backed by the reliability that dropped on the results of beam modeling and verification of dosimetric calculations. (Author)

  18. Analysis of radioactive cobalt

    International Nuclear Information System (INIS)

    1977-01-01

    This is a manual published by Science and Technology Agency, Japan, which prescribes on the analysis method for radioactive cobalt which is a typical indexing nuclide among the radioactive nuclides released from nuclear facilities. Since the released cobalt is mainly discharged to coastal region together with waste water, this manual is written for samples of sea water, sea bottom sediments and marine organisms. Radioactive cobalt includes the nuclides of 57 co, 58 Co, 60 Co, etc., the manual deals with them as a whole as 60 Co of long half life. Though 60 Co analysis has become feasible comparatively simply due to scintillation or semi-conductor spectrometry, trace 60 Co analysis is performed quantitatively by co-precipitation or collection into alumina and scintillation spectrometry. However, specific collecting operation and γ-γ coincidence measurement have been required so far. This manual employs 60 Co collection by means of ion-exchange method and measurement with low background GM counting system, to analyze quantitatively and rapidly low level 60 Co. It is primarily established as the standard analyzing method for the survey by local autonomous bodies. It is divided into 4 chapters including introduction sea water, marine organisms, and sea bottom sediments. List of required reagents is added in appendix. (Wakatsuki, Y.)

  19. Formation of amino acids by cobalt-60 irradiation of hydrogen cyanide solutions

    Science.gov (United States)

    Sweeney, M. A.; Toste, A. P.; Ponnamperuma, C.

    1976-01-01

    Experiments were conducted to study the pathway for the prebiotic origin of amino acids from hydrogen cyanide (HCN) under the action of ionizing radiation considered as an effective source of energy on the primitive earth. The irradiations were performed in a cobalt-60 source with a dose rate of 200,000 rad/hr. Seven naturally occurring amino acids are identified among the products formed by the hydrolysis of gamma-irradiated solutions of HCN: glycine, alanine, valine, serine, threonine, aspartic acid, and glutamic acid. The identity of these amino acids is established by gas chromatography and mass spectrometry. Control experiments provided evidence that the amino acids are not the result of contamination.

  20. On the application of a simple model of cobalt-60 beams

    International Nuclear Information System (INIS)

    Gantchew, M.G.

    1979-01-01

    The simple mathematical model of the dose distribution in a phantom irradiated by a single beam of cobalt-60 gamma rays (Wilks, R.J., and Sutcliffe, J.F., 1977, Phys. Med. Biol., vol. 22, 737) requires measurements for each particular field size and diaphragm setting to describe the decrement functions (dose distributions along a straight line perpendicular to the central ray). Measurements made with a Gammatron-3 have shown satisfactory agreement between computed and measured lateral dose distributions for different diaphragm settings if the experimental data was first subjected to additional processing, and Wilks and Sutcliffe's model can therefore be applied to any diaphragm setting using this modification. Field sizes can therefore be entered according to diaphragm indicator reading in dose planning. (U.K.)

  1. High accumulation of cobalt-60 by the particular organ or part of some species in mollusca

    International Nuclear Information System (INIS)

    Yoshida, Katsuhiko

    1981-01-01

    A large amounts of samples in marine Cephalopoda and Tridacna were sampled in north west pacific ocean, near Japan. The samples were separated into organs or parts for determination of Co-60 concentration. A peculiar accumulation of Co-60 by the branchial heart of Octopus was also recognized in field condition, but it had become apparent that branchial heart of squid had not same ability. Liver of Cephalopoda had the ability to highly accumulate the Co-60 and specific activity of squid was one order highter than Octopus. The concentration of Cobalt-60 in visceral muss kidney of Tridacna maxima lineally increased with increasing shell length but that in other soft parts was kept constant. After examination of the other papers it was assumed that Co-60 highly accumulated in these organs was transfered by the food chain. (author)

  2. Plaquing procedure for infectious hematopoietic necrosis virus

    Science.gov (United States)

    Burke, J.A.; Mulcahy, D.

    1980-01-01

    A single overlay plaque assay was designed and evaluated for infectious hematopoietic necrosis virus. Epithelioma papillosum carpio cells were grown in normal atmosphere with tris(hydroxymethyl)aminomethane- or HEPES (N-2-hydroxyethylpiperazine-N'-2-ethanesulfonic acid)-buffered media. Plaques were larger and formed more quickly on 1- to 3-day-old cell monolayers than on older monolayers. Cell culture medium with a 10% addition of fetal calf serum (MEM 10) or without serum (MEM 0) were the most efficient virus diluents. Dilution with phosphate-buffered saline, saline, normal broth, or deionized water reduced plaque numbers. Variations in the pH (7.0 to 8.0) of a MEM 0 diluent did not affect plaque numbers. Increasing the volume of viral inoculum above 0.15 ml (15- by 60-mm plate) decreased plaquing efficiency. Significantly more plaques occurred under gum tragacanth and methylcellulose than under agar or agarose overlays. Varying the pH (6.8 to 7.4) of methylcellulose overlays did not significantly change plaque numbers. More plaques formed under the thicker overlays of both methylcellulose and gum tragacanth. Tris(hydroxymethyl)aminomethane and HEPES performed equally well, buffering either medium or overlay. Plaque numbers were reduced when cells were rinsed after virus adsorption or less than 1 h was allowed for adsorption. Variation in adsorption time between 60 and 180 min did not change plaque numbers. The mean plaque formation time was 7 days at 16 degrees C. The viral dose response was linear when the standardized assay was used.

  3. Operational Qualification (OQ) Of MINTEC-Sinagama After Cobalt-60 Sources Replenishment

    International Nuclear Information System (INIS)

    Ruzalina Baharin; Hasan Sham; Ahsanulkhaliqin Abdul Wahab

    2014-01-01

    Activity on cobalt-60 sources replenishment at MINTec-Sinagama had been held in May 2014 with total strength of gamma as 440,000 Ci. Therefore, operational qualification (OQ) needs to be done in order to ensure that Sinagama plant is operating well and deliver suitable doses to the customer's products. In this work, three dose mapping exercises were carried out to establish dose distributions and dose reproducibility of plant, which are corresponded to the density of irradiator container (tote) and absorbed dose at normal operation. Dosimeters used were ceric cerous produced by SSDL, Malaysian Nuclear Agency and placed on three planes that represent three-dimensional array. They were located at certain intervals throughout the tote. This paper describes the OQ process and a bit touch on replenishment activity. (author)

  4. Forward-planned intensity modulated radiation therapy using a cobalt source: A dosimetric study in breast cancer

    Directory of Open Access Journals (Sweden)

    Savino Cilla

    2013-01-01

    Full Text Available This analysis evaluates the feasibility and dosimetric results of a simplified intensity-modulated radiotherapy (IMRT treatment using a cobalt-therapy unit for post-operative breast cancer. Fourteen patients were included. Three plans per patient were produced by a cobalt-60 source: A standard plan with two wedged tangential beams, a standard tangential plan optimized without the use of wedges and a plan based on the forward-planned "field-in-field" IMRT technique (Co-FinF where the dose on each of the two tangential beams was split into two different segments and the two segments weight was determined with an iterative process. For comparison purposes, a 6-MV photon standard wedged tangential treatment plan was generated. D mean , D 98% , D 2% , V 95% , V 107%, homogeneity, and conformity indices were chosen as parameters for comparison. Co-FinF technique improved the planning target volume dose homogeneity compared to other cobalt-based techniques and reduced maximum doses (D 2% and high-dose volume (V 110% . Moreover, it showed a better lung and heart dose sparing with respect to the standard approach. The higher dose homogeneity may encourage the adoption of accelerated-hypofractionated treatments also with the cobalt sources. This approach can promote the spread of breast conservative treatment in developing countries.

  5. Chronic cardiac arrhythmias produced by focused cobalt-60 gamma irradiation of the canine atria

    International Nuclear Information System (INIS)

    Dick, H.L.H.; Saylor, C.B.; Reeves, M.M.; Davies, M.J.

    1979-01-01

    Cardiac arrhythmias following exposure of the human heart to ionizing radiation have been reported. Earlier experiments involving irradiation of the hearts of various animals failed to consistently produce similar arrhythmias. In the present work, cobalt-60 irradiation was focused on the interatrial septum of the hearts of 12 dogs. Ten animals developed arrhythmias: These were repetive junctional and atrial tachycardias, repetitive atrial fibrillation, and type one, second-degree atrial ventricular block. The duration varied from 1 to 52 days, with onsets varying from 48 to 146 days postirradiation

  6. Establishing the estimation model on radiation level at the ambience of 60Co radiotherapy treatment room based on NCRP REPORT No.151

    International Nuclear Information System (INIS)

    Yang Haiyou; Liu Liping; Liang Yueqin; Yu Shui

    2009-01-01

    Objective: To establish the estimation model to evaluate the radiation level at the ambience of 60 Co radiotherapy treatment room. Methods: The estimation model derives from NCRP REPORT No.151- S tructural Shielding Design and Evaluation for Megavoltage X-and Gamma-Ray Radiotherapy Facilities b y making appropriate adjustment, which presents the calculation methods on radiation level at the ambience of megavoltage medical electron linear accelerator treatment room. Results: The application scope of estimation model from NCRP REPORT No.151 is extended to γ-radiotherapy facilities, and it can be regarded as a new model for calculating the radiation level at the ambience of 60 Co radiotherapy treatment room. Conclusion: The estimation model has certain reference value to evaluate the radiation level at the ambience of 60 Co radiotherapy treatment room. (authors)

  7. Study to use graded cobalt adjuster in 540 MWe PHWR

    International Nuclear Information System (INIS)

    Raj, Manish; Fernando, M.P.S.; Pradhan, A.S.; Kumar, A.N.

    2007-01-01

    Full text: There are 17 adjusters in 540 MWe PHWR, which are essentially provided for xenon override function. They also provide flux flattening being in the central region of the reactor core. The present design of adjusters consists of stainless steel tube. The adjuster rods are grouped into 8 banks for movement. Since adjusters are normally fully inserted during reactor operation, they are best suited for production of cobalt 60. The nickel-plated cobalt in the form of either slugs or pellet are used for the design of cobalt pencils. The number of pencils can be varied to optimize the reactivity load and cobalt 60 production requirement. The worth and activity of cobalt adjusters have been worked out considering different pin configuration for the adjuster assembly. To start with we have assumed all adjusters throughout its length are of the same configuration. The flux depression factors within the cobalt pencils have been considered in the estimations of the specific and total cobalt 60 activities. The option of using graded cobalt adjusters, where different pin configuration along the length is considered for better flux flattening

  8. Influence of Adaptive Statistical Iterative Reconstruction on coronary plaque analysis in coronary computed tomography angiography

    DEFF Research Database (Denmark)

    Precht, Helle; Kitslaar, Pieter H; Broersen, Alexander

    2016-01-01

    performed. Images were reconstructed using FBP, 30% and 60% adaptive statistical IR (ASIR). Coronary plaque analysis was performed as per patient and per vessel (LM, LAD, CX and RCA) measurements. Lumen and vessel volumes and plaque burden measurements were based on automatic detected contours in each...... reconstruction. Lumen and plaque intensity measurements and HU based plaque characterization were based on corrected contours copied to each reconstruction. RESULTS: No significant changes between FBP and 30% ASIR were found except for lumen- (-2.53 HU) and plaque intensities (-1.28 HU). Between FBP and 60% ASIR...... the change in total volume showed an increase of 0.94%, 4.36% and 2.01% for lumen, plaque and vessel, respectively. The change in total plaque burden between FBP and 60% ASIR was 0.76%. Lumen and plaque intensities decreased between FBP and 60% ASIR with -9.90 HU and -1.97 HU, respectively. The total plaque...

  9. Influence of Adaptive Statistical Iterative Reconstruction on coronary plaque analysis in coronary computed tomography angiography.

    Science.gov (United States)

    Precht, Helle; Kitslaar, Pieter H; Broersen, Alexander; Dijkstra, Jouke; Gerke, Oke; Thygesen, Jesper; Egstrup, Kenneth; Lambrechtsen, Jess

    The purpose of this study was to study the effect of iterative reconstruction (IR) software on quantitative plaque measurements in coronary computed tomography angiography (CCTA). Thirty patients with a three clinical risk factors for coronary artery disease (CAD) had one CCTA performed. Images were reconstructed using FBP, 30% and 60% adaptive statistical IR (ASIR). Coronary plaque analysis was performed as per patient and per vessel (LM, LAD, CX and RCA) measurements. Lumen and vessel volumes and plaque burden measurements were based on automatic detected contours in each reconstruction. Lumen and plaque intensity measurements and HU based plaque characterization were based on corrected contours copied to each reconstruction. No significant changes between FBP and 30% ASIR were found except for lumen- (-2.53 HU) and plaque intensities (-1.28 HU). Between FBP and 60% ASIR the change in total volume showed an increase of 0.94%, 4.36% and 2.01% for lumen, plaque and vessel, respectively. The change in total plaque burden between FBP and 60% ASIR was 0.76%. Lumen and plaque intensities decreased between FBP and 60% ASIR with -9.90 HU and -1.97 HU, respectively. The total plaque component volume changes were all small with a maximum change of -1.13% of necrotic core between FBP and 60% ASIR. Quantitative plaque measurements only showed modest differences between FBP and the 60% ASIR level. Differences were increased lumen-, vessel- and plaque volumes, decreased lumen- and plaque intensities and a small percentage change in the individual plaque component volumes. Copyright © 2016 Society of Cardiovascular Computed Tomography. Published by Elsevier Inc. All rights reserved.

  10. Comparison of three methods for the calibration of cobalt-60 teletherapy machine

    International Nuclear Information System (INIS)

    Adewole, O.O.; Akinlade, B.I.; Oyekunle, O.E.; Ejeh, J.

    2011-01-01

    Two methods of indirect determination of dose rate (machine output) from the Cobalt-60 Teletherapy machines has been reviewed and compared with conventional measurement with dosimetry devices. The dose rate were determined by: (i) Conventional measurement (ii) Application of the law of radioactive decay and (iii) Assumption of 1 % radioactive decomposition per month. The dose rate at the depth of maximum dose (Z m ax), collimator size of 10cm x 10cm and Source to Skin Distance (SSD) of 80cm obtained from these methods were 203.7200cGy/min, 203.8090cGy/min and 203.9530cGy/min respectively. The ratio of dose rate obtained from measurement to that from calculations is within the tolerance value of 2%.

  11. Radio cobalt in French rivers

    International Nuclear Information System (INIS)

    Lambrechts, A.; Baudin-Jaulent, Y.

    1996-01-01

    The isotopes 58 and 60 of cobalt present in liquid wastes from nuclear plants or from fuel reprocessing plant of Marcoule are fixed in the different compartments of French rivers. The activity levels of radio-cobalt vary according to the sampled compartments nature (bryophyta > immersed plants > sediment > fish). Elsewhere, laboratory experimentations show that the contamination of fish occurs essentially from the water way rather than from food. Cobalt is mainly fixed by kidneys; muscles is no more than 30 % of the total fish activity. (author)

  12. Concrete Shielding For Radiation Safety And Unexpected Dangerous Inside Cobalt-60 Industrial Irradiator

    International Nuclear Information System (INIS)

    Keshk, A.B.; Aly, R.A.

    2011-01-01

    The study shows a proposed destruction inside one of three cobalt-60 industrial irradiators to determine and reduce the negative results, to improve and modify emergency plan to face terrorism works. The results show the performance of concrete shielding (walls and ceiling) contains the bad effect of dynamic pressures. The explosion forces are prevented to destructive by performance of their concrete shielding, which will contain the most components of devastated systems inside each irradiator after explosion. Shield penetration like electrical cable tunnels, pushers holes, hole with removable plug, product boxes openings, lens opening and ozone duct are affected badly by destruction. Through probability of transporting, some of devastated parts of broken radioactive cobalt- 60 pencils from inside radiation concreter room to outside (surrounded environment) are maintained and causing very danger radiation exposure by gamma rays outside irradiator. A necessity needs to modify emergency plan to prevent any explosive materials to enter inside the main building (irradiation sale) and also discovering any explosive materials which are placed inside the product boxes before passing to inside irradiator. The minimizing radiation exposure (2 mrem/h) inside underground radiation shelters are maintained by reducing radiation dose exerted from a nuclear explosion of 20 kT about 1 km away to a safe value, and calculating the protective factors of radiation main building basements are more than 40 (safety factor) as they are located under ground level, are surrounded by sandy soil and are constructed by concrete. The study shows the proposed basements of the main building maintain success to use as under ground safe radiation shelter (during emergency) with separate safe radiation trace. It begins from the main opening of irradiation sale and leads to underground proposed shelter through modified main stair

  13. Quarantine treatment for Sitophilus zeamais (Coleoptera: Curculionidae) through gamma radiation from Cobalt-60

    International Nuclear Information System (INIS)

    Ramos, Amanda Cristina Oliveira; Potenza, Marcos Roberto

    2009-01-01

    Pests like beetles, moths, fungus and mites normally attack stored products such as grains, spices, flours, brans and tobacco in bale. Among these pests the Sitophilus zeamais is one of the most important pests due its elevated potential of reproduction, infesting a great number of products, inducing great damages. This work had as objective to determine the efficacy of gamma radiation from Cobalt-60 as quarantine treatment for S. zeamais. The insects used in this experiment were reared in maize grains, at the Laboratorio de Artropodes of the Instituto Biologico/SP, on climatic room with 27 ± 2 deg C of temperature and relative humidity of 70 ± 5%. Samples containing 25 adult insects were put in acrylic recipients measuring 2.8cm x 2.8cm. Each treatment had four repetitions, in a total of 100 insects for treatment. They were irradiated with growing doses of gamma radiation: 0 (control); 0,25; 0,5; 0,75; 1,0; 1,25; 1,5; 1,75; 2,0; 2,25 2,5; 2,75; 3,0; 3,5 e 4,0 kGy, in a experimental irradiator of Cobalt-60, model Gammacell-220, located at the Centro de Tecnologia da Radiacoes - CTR of the Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN/SP. After irradiation, the samples were transferred to plastic recipients measuring 3,5cm x 10cm, with perforated lids (to allow gaseous exchanges). After the irradiation the samples were kept in climatic room (27 ± 2 deg C and 70 ± 5%). The mortality of insects was evaluated 1 hour after the irradiation and also on the next 7 days. By the results obtained we can conclude that was the dose of 2.75 kGy that induced the immediate mortality for adult insects of the specie S. zeamais. (author)

  14. Dosimetric quality control in radiotherapy using TLD methodology

    International Nuclear Information System (INIS)

    Saravi, M.C.; Kessler, C.; Alvarez, P.E.; Feld, D.B.

    2002-01-01

    In the frame of the IAEA Co-ordinated Research Project 'Development of a Quality Assurance Program for Radiation Therapy Dosimetry in Developing Countries' a Dosimetric Quality Control Group was set up in Argentina in 1996, to develop a program in order to improve radiotherapy in the country. Nowadays, this Group, briefly called External Audit Group (EAG), is composed by the national Secondary Standard Dosimetry Laboratory (SSDL), which has the responsibility for dose determinations, traceability to international dosimetry chain and TLD measurements, and two Medical Physicists from CNEA who are working at the Oncology Hospital 'Marie Curie' in Buenos Aires. The present paper reports the activities performed by the EAG with external high energy photon beams in reference conditions and the results of two pilot studies on cobalt 60 beams in non-reference conditions. The first step of the program was to update the existing data base about the radiotherapy centres operating in the country. A form was sent to each of them in order to obtain basic information about their staff, number and type of treatment machines, brachytherapy sources, measuring devices, beam calibration, treatment planning system, simulator and other relevant data. 90 radiotherapy centres were registered in the EAG data base. Forms were completed by 75/90 centres. There are nowadays 69 cobalt 60 units and 42 LINACs operating in the country (18/42 LINACs producing high energy X ray and electron beams). EAG deals with measurements performed with mailed TLD irradiated at radiotherapy centres. Internal quality control on our TLD system is made during each audit by means of reference capsules irradiated by IAEA; external controls consist in blind tests performed by IAEA once a year. The correction factor, K en , determined at our SSDL for high energy X-rays was checked with the collaboration of IAEA and Prague National Radiation Protection Institute (PNRPI) by means of a blind test. Results for 4 MV, 6 MV

  15. Effect of antioxidants on thiobarbituric acid reactive substances of mechanically de boned chicken meat irradiated with ionizing radiation: cobalt-60 and electron beam sources

    Energy Technology Data Exchange (ETDEWEB)

    Brito, Poliana de Paula; Azevedo, Heliana de; Pomarico Neto, Walter; Roque, Claudio Vitor; Brusqui, Armando Luiz, E-mail: hgomes@cnen.gov.b, E-mail: pbrito@cnen.gov.b, E-mail: cvroque@cnen.gov.b, E-mail: abrusqui@cnen.gov.b [Brazilian Nuclear Energy Commission (LAPOC/CNEN), Pocos de Caldas, MG (Brazil); Haguiwara, Marcia Mayumi Harada; Miyagusku, Luciana, E-mail: marciamh@ital.gov.b, E-mail: lucianam@ital.gov.b [Food Technology Institute (ITAL), SP (Brazil). Meat Technology Center

    2011-07-01

    Samples of MDCM with skin were divided into three groups: control (without antioxidants), Antioxidant 1 - A1 (0.3% Sodium Polyphosphate and Sodium Erythorbate 0.05%) and Antioxidant 2 - A2 (Rosemary Extract 0.02% and {alpha}-Tocopherol 0.01%). The three batches of samples were divided into nine groups: no antioxidant and non-irradiated (Cn/I), with antioxidant A1 and non-irradiated (A1n/I), with antioxidant A2 and non-irradiated (A2n/I) without antioxidant and irradiated in Cobalt-60 source (CCo), with antioxidant A1 irradiated in Cobalt 60 source (A1Co) with antioxidant A2 irradiated in Cobalt-60 source (A2Co) with antioxidant A1 irradiated in Electron beam (A1Eb) and with antioxidant A2 irradiated in Electron beam (A2Eb). Each 100 g sample was conditioned in a transparent, low density polyethylene oxygen permeable bag, frozen overnight at a temperature of -18 +- 1 deg C in a chamber, and irradiated in this state, maintaining the temperature low with dry ice. The samples were irradiated with a dose of 3.0 kGy, used two sources of radiation: Cobalt-60 (3.1 kGy.h{sup -1}) and electron beam (2.9 kGy.s{sup -1}). After this process, the samples were evaluated during the refrigeration period (2 +- 1 deg C) for 11 days for the following analysis: total psychotropic bacteria count, thiobarbituric acid reactive substances (TBARS). The addition of antioxidants was able to reduce lipid oxidation caused by the irradiation. There were no differences between the radiation sources used in the same parameters. The better antioxidants mixture in the TBARS reducing it was rosemary extract and {alpha}-tocopherol (A2). (author)

  16. Effect of antioxidants on thiobarbituric acid reactive substances of mechanically de boned chicken meat irradiated with ionizing radiation: cobalt-60 and electron beam sources

    International Nuclear Information System (INIS)

    Brito, Poliana de Paula; Azevedo, Heliana de; Pomarico Neto, Walter; Roque, Claudio Vitor; Brusqui, Armando Luiz; Haguiwara, Marcia Mayumi Harada; Miyagusku, Luciana

    2011-01-01

    Samples of MDCM with skin were divided into three groups: control (without antioxidants), Antioxidant 1 - A1 (0.3% Sodium Polyphosphate and Sodium Erythorbate 0.05%) and Antioxidant 2 - A2 (Rosemary Extract 0.02% and α-Tocopherol 0.01%). The three batches of samples were divided into nine groups: no antioxidant and non-irradiated (Cn/I), with antioxidant A1 and non-irradiated (A1n/I), with antioxidant A2 and non-irradiated (A2n/I) without antioxidant and irradiated in Cobalt-60 source (CCo), with antioxidant A1 irradiated in Cobalt 60 source (A1Co) with antioxidant A2 irradiated in Cobalt-60 source (A2Co) with antioxidant A1 irradiated in Electron beam (A1Eb) and with antioxidant A2 irradiated in Electron beam (A2Eb). Each 100 g sample was conditioned in a transparent, low density polyethylene oxygen permeable bag, frozen overnight at a temperature of -18 +- 1 deg C in a chamber, and irradiated in this state, maintaining the temperature low with dry ice. The samples were irradiated with a dose of 3.0 kGy, used two sources of radiation: Cobalt-60 (3.1 kGy.h -1 ) and electron beam (2.9 kGy.s -1 ). After this process, the samples were evaluated during the refrigeration period (2 +- 1 deg C) for 11 days for the following analysis: total psychotropic bacteria count, thiobarbituric acid reactive substances (TBARS). The addition of antioxidants was able to reduce lipid oxidation caused by the irradiation. There were no differences between the radiation sources used in the same parameters. The better antioxidants mixture in the TBARS reducing it was rosemary extract and α-tocopherol (A2). (author)

  17. Sensory analysis of dairy products irradiated with cobalt-60 at -78 degrees C

    International Nuclear Information System (INIS)

    Hashisaka, A.E.; Einstein, M.A.; Rasco, B.A.; Hungate, F.P.; Dong, F.M.

    1990-01-01

    Sensory evaluations by healthy individuals were conducted on cobalt-60 irradiated retail dairy products which were to be incorporated into the low microbial diets of immunosuppressed patients. Irradiation (40 kGy at -78 degrees C) caused little change in product color or texture, but generally there was a decrease in overall acceptability and an increase in off-flavor and aftertaste. Modified atmosphere packaging (nitrogen, helium, or air) or antioxidant addition (ascorbyl palmitate or a combination of butylated hydroxyanisole and butylated hydroxytoluene) prior to irradiation were effective in preserving specific sensory attributes, which in some cases resulted in improved overall acceptability (helium packed peppermint ice cream; ascorbyl palmitate treated strawberry yogurt bars) when compared to untreated irradiated products

  18. Radiotherapy for cutaneous cancers with xeroderma pigmentosum; Radiotherapie des cancers cutanes au cours du xeroderma pigmentosum

    Energy Technology Data Exchange (ETDEWEB)

    Ben Salah, H.; Bahri, M.; Turki, H.; Abdelmoula, M.; Frikha, M.; Daoud, J. [Service de radiotherapie, CHU Habib-Bourguiba, route Majida-Bouleila, 3029 Sfax (Tunisia)

    2011-08-15

    Purpose. - To analyze the therapeutic results of cutaneous cancers on xeroderma pigmentosum through a series of 15 patients treated by radiotherapy. Patients and methods. - Between 1993 and 2006, 15 patients with xeroderma pigmentosum and having cutaneous cancers were treated in the Radiotherapy Department of university hospital Habib-Bourguiba of Sfax in Tunisia. Seventy-three percent of the cases occurred in male patients and the mean age of appearance of the first tumour was 18.2 years. Tumour histology was squamous cell carcinoma in 74% of the cases. The total number of cutaneous tumours was 84. Ten patients had a surgical resection. Four patients did not respond to chemotherapy. The modality of irradiation was decided according to the size, thickness and localization of the tumour. The dose of radiotherapy was 60 Gy or equivalent with classic irradiation. Results. - The total number of lesions treated with radiotherapy was 64. Forty-three lesions were treated with contact-therapy, ten with brachytherapy and 11 with cobalt-therapy. The following acute complications were observed: cutaneous infection (53.3% of patients), radio-epithelitis (80% of patients) and necroses (33.3% of patients). Evaluation after treatment showed a clinical complete remission in 73% of the cases. Late effects were noted in seven cases: telangiectasia and cutaneous atrophy. A recurrence in the irradiated zone was observed in one case. A nodal metastasis was observed in two cases. Another patient presented lung metastases. After a median follow up of 37.2 months, four patients died, seven are alive with cutaneous cancer and four are alive with complete remission. Conclusion. - Radiotherapy is a possible and effective therapeutic alternative. Dose and methods are not defined for xeroderma pigmentosum. (authors)

  19. Construction of an apparatus for nuclear orientation measurements at low temperatures. Application to neodymium-cobalt alloy; Realisation d'un appareil pour des mesures d'orientation nucleaire a basse temperature. Application a l'alliage neodyme-cobalt

    Energy Technology Data Exchange (ETDEWEB)

    Mayer, E [Commissariat a l' Energie Atomique, Grenoble (France). Centre d' Etudes Nucleaires

    1965-10-01

    We describe experiments along which has been studied the anisotropy of {gamma} radiations emitted by oriented nuclei. We have used the great hyperfine fields acting on nuclei in ferromagnetic metals so as to produce alignment at low temperature. By irradiation we obtained a few cobalt 60 nuclei in our samples which were then cooled down to 0,01 K. The anisotropic rate of the 1,33 MeV {gamma} radiation was measured in function of the sample temperature, using as thermometer the anisotropy of {gamma} radiation emitted by cobalt 60 nuclei in a cobalt single crystal. Cobalt 60 was lined up in a cobalt nickel alloy (40% Ni). The hyperfine field at the cobalt was measured compared to the effective field in metallic cobalt: Heff(Co Ni)/Heff(Co metal) = 0.71 {+-} 0.12. These results are in good agreement with specific heat measurements made previously. Cobalt 60 has been polarised in a neodymium-cobalt alloy (NdCo{sub 5}). The field at the cobalt in NdCo{sub 5} has been measured compared to the field in metallic cobalt and taking the non-saturation into account we found 165000 oersteds < Heff(NdCo{sub 5}) < 220000 oersteds. (author) [French] Nous decrivons des experiences au cours desquelles nous avons etudie l'anisotropie de rayonnements {gamma} emis par des noyaux orientes. Nous avons utilise les grands champs hyperfins agissant sur las noyaux dans les metaux ferromagnetiques pour produire l'alignement a basse temperature. Par irradiation nous avons obtenu quelques noyaux de cobalt 60 dans nos echantillons qui furent ensuite refroidis a 0,01 K. Le degre d'anisotropie du rayonnement {gamma} de 1,33 MeV fut mesure en fonction de la temperature de l'echantillon en utilisant l'anisotropie du rayonnement {gamma} de noyaux de cobalt 60 dans un monocristal de cobalt metallique utilise comme thermometre. Le cobalt 60 a ete aligne dans un alliage de cobalt-nickel (40% Ni). Le champ hyperfin au niveau du cobalt a ete mesure par rapport au champ effectif dans le cobalt metallique

  20. Distortion-free diffusion MRI using an MRI-guided Tri-Cobalt 60 radiotherapy system: Sequence verification and preliminary clinical experience.

    Science.gov (United States)

    Gao, Yu; Han, Fei; Zhou, Ziwu; Cao, Minsong; Kaprealian, Tania; Kamrava, Mitchell; Wang, Chenyang; Neylon, John; Low, Daniel A; Yang, Yingli; Hu, Peng

    2017-10-01

    Monitoring tumor response during the course of treatment and adaptively modifying treatment plan based on tumor biological feedback may represent a new paradigm for radiotherapy. Diffusion MRI has shown great promises in assessing and predicting tumor response to radiotherapy. However, the conventional diffusion-weighted single-shot echo-planar-imaging (DW-ssEPI) technique suffers from limited resolution, severe distortion, and possibly inaccurate ADC at low field strength. The purpose of this work was to develop a reliable, accurate and distortion-free diffusion MRI technique that is practicable for longitudinal tumor response evaluation and adaptive radiotherapy on a 0.35 T MRI-guided radiotherapy system. A diffusion-prepared turbo spin echo readout (DP-TSE) sequence was developed and compared with the conventional diffusion-weighted single-shot echo-planar-imaging sequence on a 0.35 T MRI-guided radiotherapy system (ViewRay). A spatial integrity phantom was used to quantitate and compare the geometric accuracy of the two diffusion sequences for three orthogonal orientations. The apparent diffusion coefficient (ADC) accuracy was evaluated on a diffusion phantom under both 0 °C and room temperature to cover a diffusivity range between 0.40 × 10 -3 and 2.10 × 10 -3 mm 2 /s. Ten room temperature measurements repeated on five different days were conducted to assess the ADC reproducibility of DP-TSE. Two glioblastoma (GBM) and six sarcoma patients were included to examine the in vivo feasibility. The target registration error (TRE) was calculated to quantitate the geometric accuracy where structural CT or MR images were co-registered to the diffusion images as references. ADC maps from DP-TSE and DW-ssEPI were calculated and compared. A tube phantom was placed next to patients not treated on ViewRay, and ADCs of this reference tube were also compared. The proposed DP-TSE passed the spatial integrity test (< 1 mm within 100 mm radius and < 2 mm within 175 mm radius

  1. Heating analysis of cobalt adjusters in reactor core

    International Nuclear Information System (INIS)

    Mei Qiliang; Li Kang; Fu Yaru

    2011-01-01

    In order to produce 60 Co source for industry and medicine applications in CANDU-6 reactor, the stainless steel adjusters were replaced with the cobalt adjusters. The cobalt rod will generate the heat when it is irradiated by neutron and γ ray. In addition, 59 Co will be activated and become 60 Co, the ray released due to 60 Co decay will be absorbed by adjusters, and then the adjusters will also generate the heat. So the heating rate of adjusters to be changed during normal operation must be studied, which will be provided as the input data for analyzing the temperature field of cobalt adjusters and the relative heat load of moderator. MCNP code was used to simulate whole core geometric configuration in detail, including reactor fuel, control rod, adjuster, coolant and moderator, and to analyze the heating rate of the stainless steel adjusters and the cobalt adjusters. The maximum heating rate of different cobalt adjuster based on above results will be provided for the steady thermal hydraulic and accident analysis, and make sure that the reactor is safe on the thermal hydraulic. (authors)

  2. Research and design of the moving system for the cobalt-60 industrial irradiator

    International Nuclear Information System (INIS)

    Le Minh Tuan; Tran Khac An; Cao Van Chung; Phan Phuoc Thang

    2016-01-01

    On the way of localization of Cobalt-60 industrial irradiators, Research and Development Center for Radiation Technology (VINAGAMMA) has successfully designed and manufactured the first version of Co-60 industrial irradiator, VINAGA1. The second version of Co-60 industrial irradiator has been studied and designed by VINAGAMMA in the frame of the scientific project No. DTCB.02/15/TTNCTK. The nucleus of a Co-60 industrial irradiator is a mechanical system inside an irradiation room namely a tote box moving system. This report presents the tote box moving system designed by VINAGAMMA. The tote box moving system contains 52 tote boxes with the dimensions of 50 cm (w) × 70 cm (l) × 150 cm (h) that are moving around the source racks in the manner of 4 passes and 2 levels. The irradiator with this tote box moving system has good specifications: The minimum time of an irradiation cycle is 1h 20 min and the dose uniformity ratio (DUR) at the product densities of 0.1 g/cm 3 and 0.5 g/cm 3 is 1.4 and 1.8, respectively. Radiation energy utilization efficiency at the product densities of 0.1 g/cm 3 and 0.5 g/cm 3 is 19.7% and 48.8%, respectively. These specifications meet the requirements for a multi-purpose Co-60 industrial irradiator and the present irradiation requirements in Vietnam. (author)

  3. An experimental study on cervix cancer with combination of HSV-TK/GCV suicide gene therapy system and 60Co radiotherapy

    International Nuclear Information System (INIS)

    Chen, Daozhen; Tang, Qiusha

    2010-01-01

    To evaluate the killing effect of HSV-TK/GCV suicide gene therapy system combined with 60 Co radiotherapy on human cervical cancer Hela cell line in vitro and in vivo, and to explore the radiosensitization by HSV-TK/GCV system. HSV-TK/GCV suicide gene therapy system and 60 Co radiotherapy were used separately or in combination on human cervical cancer Hela cell line in vitro and in vivo to compare their effects. Colony formation test and the rate of radiosensitization effect (E/O) were employed to observed the radiosensitization by HSV-TK/GCV system. HSV-TK/GCV suicide gene therapy system had strong therapeutic effects on Hela cells in vitro and in vivo (the inhibition rates were 45.8% and 39.5%, respectively), moreover, the combined administration of gene therapy and radiotherapy had stronger therapeutic effects in vitro and in vivo (the inhibition rate was 87.5% in vitro, and the inhibition rate was 87.9% in vivo) (P < 0.01). The inhibition rate by radiotherapy alone was 42.4% in vitro and 35.8% in vivo. The sensitivity of combined therapy to radiotherapy increased more than that of therapy alone, the ability of colony formation decreased (P < 0.01). The rate of radiosensitivity effect (E/O) was 3.17(> 1.4), indicating HSV-TK/GCV system could exert a sensitizing effect on 60 Co radiotherapy of the transplanted human cervical cancer cell in nude mice. HSV-TK/GCV system had radiosensitization. Gene therapy combined with radiotherapy may be a good supplementary method for cervix cancer synthetic treatment

  4. Cobalt accumulation and circulation by blackgum trees

    International Nuclear Information System (INIS)

    Thomas, W.A.

    1975-01-01

    Blackgum (Nyssa sylvatica Marsh.) trees accumulate far greater concentrations of cobalt in mature foliage than do other species on the same site (363 ppM in ash of blackgum, compared with about 3 ppM by mockernut hickory and about 1 ppM by red maple, tulip tree, and white oak). Cobalt concentrations in dormant woody tissues of blackgum also significantly exceed those in the other four species. Inoculation of six blackgums with 60 Co revealed that cobalt remains mobile in the trees for at least 3 years. Foliar concentrations of stable cobalt increase uniformly until senescence. In late August, foliage accounts for only 9 percent of total tree weight but 57 percent of total tree cobalt. Losses of cobalt from trees occur almost entirely by leaf abscission, and the loss rates of weight and cobalt from decomposing litter are similar. Retention of cobalt in the biologically active soil layers perpetuates zones of cobalt concentration created by this species in woodlands

  5. Analysis and development of methods of correcting for heterogeneities to cobalt-60: computing application

    International Nuclear Information System (INIS)

    Kappas, K.

    1982-11-01

    The purpose of this work is the analysis of the influence of inhomogeneities of the human body on the determination of the dose in Cobalt-60 radiation therapy. The first part is dedicated to the physical characteristics of inhomogeneities and to the conventional methods of correction. New methods of correction are proposed based on the analysis of the scatter. This analysis allows to take account, with a greater accuracy of their physical characteristics and of the corresponding modifications of the dose: ''the differential TAR method'' and ''the Beam Substraction Method''. The second part is dedicated to the computer implementation of the second method of correction for routine application in hospital [fr

  6. EFTF cobalt test assembly results

    International Nuclear Information System (INIS)

    Rawlins, J.A.; Wootan, D.W.; Carter, L.L.; Brager, H.R.; Schenter, R.E.

    1988-01-01

    A cobalt test assembly containing yttrium hydride pins for neutron moderation was irradiated in the Fast Flux Test Facility during Cycle 9A for 137.7 equivalent full power days at a power level fo 291 MW. The 36 test pins consisted of a batch of 32 pins containing cobalt metal to produce Co-60, and a set of 4 pins with europium oxide to produce Gd-153, a radioisotope used in detection of the bone disease Osteoporosis. Post-irradiation examination of the cobalt pins determined the Co-60 produced with an accuracy of about 5 %. The measured Co-60 spatially distributed concentrations were within 20 % of the calculated concentrations. The assembly average Co-60 measured activity was 4 % less than the calculated value. The europium oxide pins were gamma scanned for the europium isotopes Eu-152 and Eu-154 to an absolute accuracy of about 10 %. The measured europium radioisotpe anc Gd-153 concentrations were within 20 % of calculated values. In conclusion, the hydride assembly performed well and is an excellent vehicle for many Fast Flux Test Facility isotope production applications. The results also demonstrate that the calculational methods developed by the Westinghouse Hanford Company are very accurate. (author)

  7. The physiological effect of cobalt on watermelon cultivation

    International Nuclear Information System (INIS)

    Yao Naihua; Jin Yafang; Sun Yaochen; Huang Yiming

    1993-01-01

    Cobalt has essential physiological action on both animals and plants. For the latter it can raise plant's nitrogen-fixing ability and saccharine content. Spray of cobalt mixed with other nutritive elements can improve the germinatit of seeds and the yield of fruit. For specifying the nutritive function of cobalt upon watermelon, isotope 60 Co was mixed into a complex leaf nutritive aqua and the regularity of transferring and absorbing cobalt in the watermelon's body was investigated

  8. Local high voltage radiotherapy with curative intent for prostatic carcinoma

    International Nuclear Information System (INIS)

    Jacobi, G.H.; Kurth, K.H.; Hohenfellner, R.

    1979-01-01

    In a 10-year interval 179 patients with prostatic carcinoma were treated by cobalt-60 teletherapy (7600 R). A selected group of 47 patients with localized disease and irradiated with curative intent had serial prostatic biopsies and were analized after a minimum follow-up of 1 year. Biopsies of half of the patients rendered definitively negative, on an average 14 months after radiotherapy. 8 patients with initial negative biopsy changed to positive secondarily. In one third of the patients histological conversion was missed, considered as radiation persister. Persistent carcinoma were of predominant low grade. 5 patients developed distant metastases 30 months after irradiation on an average. These patients had persistent positive tissue studies. Over all cumulative 5-years survival was 89%. In patients with prostatic carcinoma and local high voltage radiotherapy with curative intent (stage A through C) serial prostatic biopsies to document therapy effect seen mandatory. (orig.) 891 AJ/orig. 892 BRE [de

  9. Disinfection of the bee hive's American Foulbrood by gamma radiation from Cobalt-60

    International Nuclear Information System (INIS)

    Gosselin, P.; Charbonneau, R.

    1990-01-01

    Gamma radiation from Cobalt-60 was used to sterilize honeybee combs contaminated by Bacillus larvae. The determination of the radiosensitivity (D 10 ) was done on cultured cells in Brain Heart Infusion broth and was found to be determined at 125 Gy. The D 10 of isolated spores from contaminated combs was then determined at 0,518 kGy and the D 10 of spores irradiated in their own original environment was found at 2,05 kGy. These treated combs were then sent back in the beehives. The bees cleaned the combs thoroughly and started the storage of honey in some cells. Eggs were also layed in others. Forty five days later, there were still no sing of re-appearance of the American Foulbrood disease. (author)

  10. Dose measurements for characterization of a semi-industrial cobalt-60 gamma-irradiation facility

    International Nuclear Information System (INIS)

    Farah, K.; Jerbi, T.; Kuntz, F.; Kovacs, A.

    2006-01-01

    Cobalt-60 irradiation facility has been put into operation at the National Centre of Nuclear Sciences and Technology, Sidi-thabet, Tunisia. Its technical specifications were controlled by dosimetry commissioning experiments and compared to the data specified by the plant manufacturer. Installation qualification has been carried out to measure absorbed dose distribution in the irradiation cell and products. Two dosimeter systems were used for measurements: Red and Amber Perspex and Cellulose Triacetate (CTA). The regions of minimum and maximum absorbed dose within a homogeneous dummy product (sawdust) with a bulk density of 114kg/m 3 and the dose uniformity ratio were determined. The isodose curves and the three-dimensional views were built using an automatic geostatistical gridding method, the kriging method

  11. Construction of an apparatus for nuclear orientation measurements at low temperatures. Application to neodymium-cobalt alloy

    International Nuclear Information System (INIS)

    Mayer, E.

    1965-10-01

    We describe experiments along which has been studied the anisotropy of γ radiations emitted by oriented nuclei. We have used the great hyperfine fields acting on nuclei in ferromagnetic metals so as to produce alignment at low temperature. By irradiation we obtained a few cobalt 60 nuclei in our samples which were then cooled down to 0,01 K. The anisotropic rate of the 1,33 MeV γ radiation was measured in function of the sample temperature, using as thermometer the anisotropy of γ radiation emitted by cobalt 60 nuclei in a cobalt single crystal. Cobalt 60 was lined up in a cobalt nickel alloy (40% Ni). The hyperfine field at the cobalt was measured compared to the effective field in metallic cobalt: Heff(Co Ni)/Heff(Co metal) = 0.71 ± 0.12. These results are in good agreement with specific heat measurements made previously. Cobalt 60 has been polarised in a neodymium-cobalt alloy (NdCo 5 ). The field at the cobalt in NdCo 5 has been measured compared to the field in metallic cobalt and taking the non-saturation into account we found 165000 oersteds 5 ) [fr

  12. Production of a datolite-based heavy concrete for shielding nuclear reactors and megavoltage radiotherapy rooms

    International Nuclear Information System (INIS)

    Mortazavi, S. M. J.; Mosleh-Shirazi, M.A.; Baradaran-Ghahfarokhi, M.; Siavashpour, Z.; Farshadi, A.; Ghafoori, M.; Shahvar, A.

    2010-01-01

    Biological shielding of nuclear reactors has always been a great concern and decreasing the complexity and expense of these installations is of great interest. In this study, we used datolite and galena minerals for production of a high performance heavy concrete. Materials and Methods: Datolite and galena minerals which can be found in many parts of Iran were used in the concrete mix design. To measure the gamma radiation attenuation of the Datolite and galena concrete samples, they were exposed to both narrow and wide beams of gamma rays emitted from a cobalt-60 radiotherapy unit. An Am-Be neutron source was used for assessing the shielding properties of the samples against neutrons. To test the compression strengths, both types of concrete mixes (Datolite and galena and ordinary concrete) were investigated. Results: The concrete samples had a density of 4420-4650 kg/m 3 compared to that of ordinary concrete (2300-2500 kg/m 3 ) or barite high density concrete (up to 3500 kg/m 3 ). The measured half value layer thickness of the Datolite and galena concrete samples for cobalt-60 gamma rays was much less than that of ordinary concrete (2.56 cm compared to 6.0 cm). Furthermore, the galena concrete samples had a significantly higher compressive strength as well as 20% more neutron absorption. Conclusion: The Datolite and galena concrete samples showed good shielding/engineering properties in comparison with other reported samples made, using high-density materials other than depleted uranium. It is also more economic than the high-density concretes. Datolite and galena concrete may be a suitable option for shielding nuclear reactors and megavoltage radiotherapy rooms.

  13. Long-term effects on carotid intima-media thickness after radiotherapy in patients with nasopharyngeal carcinoma

    International Nuclear Information System (INIS)

    Huang, Tai-Lin; Huang, Chi-Ren; Tsai, Nai-Wen; Kung, Chia-Te; Wang, Hung-Chen; Lin, Wei-Che; Cheng, Ben-Chung; Su, Yu-Jih; Chang, Ya-Ting; Chang, Chuang-Rung; Tan, Teng-Yeow; Hsu, Hsuan-Chih; Lu, Cheng-Hsien; Chen, Hui-Chun; Lin, Hsin-Ching; Chien, Chih-Yen; Fang, Fu-Min; Huang, Chih-Cheng; Chang, Hsueh-Wen; Chang, Wen-Neng

    2013-01-01

    Vascular abnormalities are the predominant histologic changes associated with radiation in nasopharyngeal carcinoma (NPC). This study examined if the duration after radiotherapy correlates with the progression of carotid intima-media thickness (IMT) and investigated its relationship with inflammatory markers. One hundred and five NPC patients post-radiotherapy for more than one year and 25 healthy control subjects were examined by B-mode ultrasound for IMT measurement at the far wall of the common carotid artery (CCA). Surrogate markers including lipid profile, HbA1c, and high sensitive C-reactive protein (hs-CRP) were assessed. The IMT of CCA was significantly increased in NPC patients and carotid plaque was detected in 38 NPC patients (38/105, 36.2%). Significant risk factors for carotid plaques included age, duration after radiotherapy, and HbA1c levels. Age, duration after radiotherapy, hs-CRP, HbA1c, and platelet count positively correlated with IMT. The cut-off value of age and duration after radiotherapy for the presence of plaque was 52.5 years and 42.5 months, respectively. In NPC subjects, multiple linear regression analysis revealed that age, gender, duration after radiotherapy and platelet counts were independently associated with CCA IMT. After adjustments for age, gender and platelet counts, IMT increased in a linear manner with duration after radiotherapy. Radiation-induced vasculopathy is a dynamic and progressive process due to late radiation effects. Extra-cranial color-coded duplex sonography can be part of routine follow-up in NPC patients aged ≥50 years at 40 months post-radiotherapy

  14. Radiotherapy for cutaneous cancers with xeroderma pigmentosum

    International Nuclear Information System (INIS)

    Ben Salah, H.; Bahri, M.; Turki, H.; Abdelmoula, M.; Frikha, M.; Daoud, J.

    2011-01-01

    Purpose. - To analyze the therapeutic results of cutaneous cancers on xeroderma pigmentosum through a series of 15 patients treated by radiotherapy. Patients and methods. - Between 1993 and 2006, 15 patients with xeroderma pigmentosum and having cutaneous cancers were treated in the Radiotherapy Department of university hospital Habib-Bourguiba of Sfax in Tunisia. Seventy-three percent of the cases occurred in male patients and the mean age of appearance of the first tumour was 18.2 years. Tumour histology was squamous cell carcinoma in 74% of the cases. The total number of cutaneous tumours was 84. Ten patients had a surgical resection. Four patients did not respond to chemotherapy. The modality of irradiation was decided according to the size, thickness and localization of the tumour. The dose of radiotherapy was 60 Gy or equivalent with classic irradiation. Results. - The total number of lesions treated with radiotherapy was 64. Forty-three lesions were treated with contact-therapy, ten with brachytherapy and 11 with cobalt-therapy. The following acute complications were observed: cutaneous infection (53.3% of patients), radio-epithelitis (80% of patients) and necroses (33.3% of patients). Evaluation after treatment showed a clinical complete remission in 73% of the cases. Late effects were noted in seven cases: telangiectasia and cutaneous atrophy. A recurrence in the irradiated zone was observed in one case. A nodal metastasis was observed in two cases. Another patient presented lung metastases. After a median follow up of 37.2 months, four patients died, seven are alive with cutaneous cancer and four are alive with complete remission. Conclusion. - Radiotherapy is a possible and effective therapeutic alternative. Dose and methods are not defined for xeroderma pigmentosum. (authors)

  15. Sci-Thur PM – Brachytherapy 04: Commissioning and Implementation of a Cobalt-60 High Dose Rate Brachytherapy Source

    Energy Technology Data Exchange (ETDEWEB)

    Dysart, Jonathan [Horizon Health Network (Canada)

    2016-08-15

    An Eckert & Ziegler Bebig Co0.A86 cobalt 60 high dose rate (HDR) brachytherapy source was commissioned for clinical use. Long-lived Co-60 HDR sources offer potential logistical and economic advantages over Ir-192 sources, and should be considered for low to medium workload brachytherapy departments where modest increases in treatment times are not a factor. In optimized plans, the Co-60 source provides a similar dose distribution to Ir-192 despite the difference in radiation energy. By switching to Co-60, source exchange frequency can be reduced by a factor of 20, resulting in overall financial savings of more than 50% compared to Ir-192 sources. In addition, a reduction in Physicist QA workload of roughly 200 hours over the 5 year life of the Co-60 source is also expected. These benefits should be considered against the modest increases in average treatment time compared to those of Ir-192 sources, as well as the centre-specific needs for operating room shielding modification.

  16. QA programme in external radiotherapy in Romania - status and perspective

    International Nuclear Information System (INIS)

    Dumitrescu, A.; Milu, C.

    2008-01-01

    Full text: Recognizing the importance of quality assurance in radiotherapy and the need to make access to radiation standards traceable to the international measurement system for every radiotherapy center, the Romanian national secondary standard dosimetry laboratory (SSDL) has started in 1999 - together with IAEA - a national quality audit programme in all the centers for external radiotherapy from Romania. At present, there are 17 radiotherapy centers in Romania, and a total of 19 teletherapy units and 4 LINCs. The programme has 3 phases: the first phase was to organize a survey in all radiotherapy centers, to collect general information on their radio therapists, medical physicists, type of equipment, dosimeters, etc. Following the survey, a quality assurance network was set up, and on-site dosimetry reviews were arranged according to a suitable timetable. The second phase consisted in performing the reference dosimetry and the calibration of the equipment. Then, a quality audit system based on mailed TLDs has been applied to all radiation beams produced by cobalt-60 therapy units and medical accelerators, in order to identify discrepancies in dosimetry larger than ± 3%. At the same time, the beam calibration performed by the SSDLs was verified. The results of the first survey were analyzed, and corrective actions were taken. A second survey was then organized, based on the mailed TLDs. This paper presents in detail the entire QA programme, its results, and the actions that are to be taken in order to improve the accuracy and consistency of the dosimetry in clinical radiotherapy in Romania. (author)

  17. Radioactive and stable cobalt concentrations in mussel in Kyushu island, Japan

    International Nuclear Information System (INIS)

    Momoshima, Noriyuki; Shiki, Atsushi; Takashima, Yoshimasa; Maki, Takao; Koriyama, Munehiro; Shimozono, Seika; Imamura, Hiroka; Nakamata, Kojiro.

    1985-01-01

    Two kinds of mussel, Septifer virgatus and Mytilus edulis, were collected from Kyushu island, Japan, in order to elucidate a background level of 60 Co, which is one of the most significant radionuclide for environmental monitoring around a nuclear power plant. The mussels were collected from 7 locations in 1983 and classified 2 or 3 groups depending on their shell size at each location. Activities of 60 Co were measured by a low-background β counter after purified by means of chemical separation and electrodeposition. Stable cobalt concentrations were determined by colorimetric method. The concentrations of cobalt in Septifer virgatus are one order higher level than that in Mytilus edulis. There are not so large difference in cobalt content depending on shell size so long as comparing them at the same location. The radioactivities in mussels show the same trend as stable cobalt. It has become apparent that Septifer virgatus has a tendency to concentrate cobalt with growing but Mytilus edulis is opposite. The cobalt-60 introduced to sea from nuclear explosions seems to be relatively constant in coastal seawater since specific activities are distributed in a narrow range in spite of kind, shell size and location. (author)

  18. Cobalt production in RAPS-1

    International Nuclear Information System (INIS)

    Krishnan, P.D.; Purandare, H.D.

    1978-01-01

    At present in RAPS-1 radioisotope Co 60 is produced by irradiating Co 59 in the adjusters which perform the function of regulation of reactivity, power and xenon override. But the manrem expenditure of the crew handling the charge and discharge of the adjusters is going to be prohibitively high. It is therefore proposed to irradiate Co 59 in the fuel channel positions. The physics optimisation study for such irradiation is presented. The burnup penalty and loss of power are estimated to produce the required quantity of Co 60 after optimising the number of cobalt pencils in a bundle and the positions of the cobalt producing channels in the reactor core. (author)

  19. Brainstem tolerance to conformal radiotherapy of skull base tumors

    International Nuclear Information System (INIS)

    Debus, J.; Hug, E.B.; Liebsch, N.J.; O'Farrel, D.; Finkelstein, D.; Efird, J.; Munzenrider, J.E.

    1997-01-01

    Purpose: The aim of this study was to analyze the long-term incidence of brainstem toxicity in patients treated for skull base tumors with high dose conformal radiotherapy. Methods and Materials: Between 1974 and 1995, 367 patients with chordomas (n = 195) and chondrosarcomas (n = 172) of the base of skull have been treated with combined megavoltage photon and 160 MeV proton radiotherapy. Following 3D treatment planning with delineation of target volumes and critical nontarget structures dose distributions and dose-volume histograms were calculated. Radiotherapy was given an 1.8 Gy or CGE (=Cobalt Gray Equivalent) dose per fraction, with prescribed target doses ranging from 63 CGE to 79.2 CGE (mean = 67.8 CGE). Doses to the brainstem surface were limited to ≤64 CGE and to the brainstem center to ≤53 CGE. Results: Follow-up time ranged from 6 months to 21.4 years (mean = 42.5 months). Brainstem toxicity was observed in 17 of 367 patients attributable to treatment, resulting in death of three patients. Actuarial rates of 5 and 10-year high-grade toxicity-free survival were 94 and 88%, respectively. Increased risk of brainstem toxicity was significantly associated with maximum dose to brainstem, volume of brainstem receiving ≥50 CGE, ≥55 CGE, and ≥60 CGE, number of surgical procedures, and prevalence of diabetes or high blood pressure. Multivariate analysis identified three independent factors as important prognosticators: number of surgical procedures (p < 0.001), volume of the brainstem receiving 60 CGE (p < 0.001), and prevalence of diabetes (p < 0.01). Conclusions: Tolerance of brainstem to fractionated radiotherapy appears to be a steep function of tissue volume included in high dose regions rather than the maximum dose of brainstem alone. In addition, presence of predisposing factors as well as extent of surgical manipulation can significantly lower brainstem tolerance in the individual patient

  20. Finite element modeling and intravascular ultrasound elastography of vulnerable plaques: parameter variation.

    NARCIS (Netherlands)

    Baldewsing, R.A.; Korte, C.L. de; Schaar, J.A.; Mastik, F.; Steen, A.F.W. van der

    2004-01-01

    BACKGROUND AND GOAL: More than 60% of all myocardial infarction is caused by rupture of a vulnerable plaque. A vulnerable plaque can be described as a large, soft lipid pool covered by a thin fibrous cap. Plaque material composition, geometry, and inflammation caused by infiltration of macrophages

  1. Dosimetric Feasibility of Hypofractionated Proton Radiotherapy for Neoadjuvant Pancreatic Cancer Treatment

    International Nuclear Information System (INIS)

    Kozak, Kevin R.; Kachnic, Lisa A.; Adams, Judith C; Crowley, Elizabeth M.; Alexander, Brian M.; Mamon, Harvey J.; Fernandez-Del Castillo, Carlos; Ryan, David P.; DeLaney, Thomas F.; Hong, Theodore S.

    2007-01-01

    Purpose: To evaluate tumor and normal tissue dosimetry of a 5 cobalt gray equivalent (CGE) x 5 fraction proton radiotherapy schedule, before initiating a clinical trial of neoadjuvant, short-course proton radiotherapy for pancreatic adenocarcinoma. Methods and Materials: The first 9 pancreatic cancer patients treated with neoadjuvant intensity-modulated radiotherapy (1.8 Gy x 28) at the Massachusetts General Hospital had treatment plans generated using a 5 CGE x 5 fraction proton regimen. To facilitate dosimetric comparisons, clinical target volumes and normal tissue volumes were held constant. Plans were optimized for target volume coverage and normal tissue sparing. Results: Hypofractionated proton and conventionally fractionated intensity-modulated radiotherapy plans both provided acceptable target volume coverage and dose homogeneity. Improved dose conformality provided by the hypofractionated proton regimen resulted in significant sparing of kidneys, liver, and small bowel, evidenced by significant reductions in the mean doses, expressed as percentage prescribed dose, to these structures. Kidney and liver sparing was most evident in low-dose regions (≤20% prescribed dose for both kidneys and ≤60% prescribed dose for liver). Improvements in small-bowel dosimetry were observed in high- and low-dose regions. Mean stomach and duodenum doses, expressed as percentage prescribed dose, were similar for the two techniques. Conclusions: A proton radiotherapy schedule consisting of 5 fractions of 5 CGE as part of neoadjuvant therapy for adenocarcinoma of the pancreas seems dosimetrically feasible, providing excellent target volume coverage, dose homogeneity, and normal tissue sparing. Hypofractionated proton radiotherapy in this setting merits Phase I clinical trial investigation

  2. Production of an economic high-density concrete for shielding megavoltage radiotherapy rooms and nuclear reactors

    International Nuclear Information System (INIS)

    Mortazavi, S. M. J.; Mosleh-Shirazi, M. A.; Maheri, M. R.; Haji-pour, A.; Yousefnia, H.; Zolghadri, S.

    2007-01-01

    In megavoltage radiotherapy rooms, ordinary concrete is usually used due to its low construction costs, although higher density concrete are sometimes used, as well. The use of high-density concrete decreases the required thickness of the concrete barrier; hence, its disadvantage is its high cost. In a nuclear reactor, neutron radiation is the most difficult to shield. A method for production of economic high-density concrete witt, appropriate engineering properties would be very useful. Materials and Methods: Galena (Pb S) mineral was used to produce of a high-density concrete. Galena can be found in many parts of Iran. Two types of concrete mixes were produced. The water-to-concrete (w/c) ratios of the reference and galena concrete mixes were 0.53 and 0.25, respectively. To measure the gamma radiation attenuation of Galena concrete samples, they were exposed to a narrow beam of gamma rays emitted from a cobalt-60 therapy unit. Results: The Galena mineral used in this study had a density of 7400 kg/m 3 . The concrete samples had a density of 4800 kg/m 3 . The measured half value layer thickness of the Galena concrete samples for cobalt 60 gamma rays was much less than that of ordinary concrete (2.6 cm compared to 6.0 cm). Furthermore, the galena concrete samples had significantly higher compressive strength (500 kg/cm 2 compared to 300 kg/cm 2 ). Conclusion: The Galena concrete samples made in our laboratories had showed good shielding/engineering properties in comparison with all samples made by using high-density materials other than depleted uranium. Based on the preliminary results, Galena concrete is maybe a suitable option where high-density concrete is required in megavoltage radiotherapy rooms as well as nuclear reactors

  3. A computer controlled tele-cobalt unit

    International Nuclear Information System (INIS)

    Brace, J.A.

    1982-01-01

    A computer controlled cobalt treatment unit was commissioned for treating patients in January 1980. Initially the controlling computer was a minicomputer, but now the control of the therapy unit is by a microcomputer. The treatment files, which specify the movement and configurations necessary to deliver the prescribed dose, are produced on the minicomputer and then transferred to the microcomputer using minitape cartridges. The actual treatment unit is based on a standard cobalt unit with a few additional features e.g. the drive motors can be controlled either by the computer or manually. Since the treatment unit is used for both manual and automatic treatments, the operational procedure under computer control is made to closely follow the manual procedure for a single field treatment. The necessary safety features which protect against human, hardware and software errors as well as the advantages and disadvantages of computer controlled radiotherapy are discussed

  4. Cobalt reduction of NSSS valve hardfacings for ALARA

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Joo Hak; Lee, Sang Sub [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of)

    1994-07-01

    This report informs NSSS designer that replacement of materials is one of the major means of ALARA implementation, and describes that NSSS valves with high-cobalt hardfacing are significant contributors to post-shutdown radiation fields caused by activation of cobalt-59 to cobalt-60. Generic procedures for implementing cobalt reduction programs for valves are presented. Discussions are presented of the general and specific design requirements for valve hardfacing in nuclear service. The nuclear safety issues involved with changing valve hardfacing materials are discussed. The common methods used to deposit hardfacing materials are described together with an explanation of the wear measurements. Wear resistance, corrosion resistance, friction coefficient, and mechanical properties of candidate hardfacing alloys are given. World-wide nuclear utility experience with cobalt-free hardfacing alloys is described. The use of low-cobalt or cobalt-free alloys in other nuclear plant components is described. 17 figs., 38 tabs., 18 refs. (Author).

  5. Cobalt reduction of NSSS valve hardfacings for ALARA

    International Nuclear Information System (INIS)

    Kim, Joo Hak; Lee, Sang Sub

    1994-07-01

    This report informs NSSS designer that replacement of materials is one of the major means of ALARA implementation, and describes that NSSS valves with high-cobalt hardfacing are significant contributors to post-shutdown radiation fields caused by activation of cobalt-59 to cobalt-60. Generic procedures for implementing cobalt reduction programs for valves are presented. Discussions are presented of the general and specific design requirements for valve hardfacing in nuclear service. The nuclear safety issues involved with changing valve hardfacing materials are discussed. The common methods used to deposit hardfacing materials are described together with an explanation of the wear measurements. Wear resistance, corrosion resistance, friction coefficient, and mechanical properties of candidate hardfacing alloys are given. World-wide nuclear utility experience with cobalt-free hardfacing alloys is described. The use of low-cobalt or cobalt-free alloys in other nuclear plant components is described. 17 figs., 38 tabs., 18 refs. (Author)

  6. The cobalt radioactive isotopes in environment; Les isotopes radioactifs du cobalt dans l'environnement

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2007-07-01

    For the year 1993 the total activity released in cobalt is 69 GBq for the whole of nuclear power plants. The part of activity in cobalt for La Hague in 1993 is 8 GBq of {sup 58}Co and 2 GBq of {sup 60}Co. The radioactive isotopes released by nuclear power plants or the reprocessing plant of La Hague under liquid effluents are shared by half between {sup 58}Co and {sup 60}Co. The exposure to sealed sources is the most important risk for the cobalt. The risk of acute exposure can associate a local irradiation of several decades of grays inducing a radiological burns, deep burn to treat in surgery by resection or graft even amputation. A global irradiation of organism for several grays induces an acute irradiation syndrome, often serious. At long term the stochastic effects are represented by leukemia and radio-induced cancers. The increase of probability of their occurrence is 1% by sievert. We must remind that the natural spontaneous probability is 25%. (N.C.)

  7. The cobalt radioactive isotopes in environment

    International Nuclear Information System (INIS)

    2007-01-01

    For the year 1993 the total activity released in cobalt is 69 GBq for the whole of nuclear power plants. The part of activity in cobalt for La Hague in 1993 is 8 GBq of 58 Co and 2 GBq of 60 Co. The radioactive isotopes released by nuclear power plants or the reprocessing plant of La Hague under liquid effluents are shared by half between 58 Co and 60 Co. The exposure to sealed sources is the most important risk for the cobalt. The risk of acute exposure can associate a local irradiation of several decades of grays inducing a radiological burns, deep burn to treat in surgery by resection or graft even amputation. A global irradiation of organism for several grays induces an acute irradiation syndrome, often serious. At long term the stochastic effects are represented by leukemia and radio-induced cancers. The increase of probability of their occurrence is 1% by sievert. We must remind that the natural spontaneous probability is 25%. (N.C.)

  8. Antivascular Endothelial Growth Factor Bevacizumab for Radiation Optic Neuropathy: Secondary to Plaque Radiotherapy

    International Nuclear Information System (INIS)

    Finger, Paul T.; Chin, Kimberly J.

    2012-01-01

    Purpose: To evaluate the intravitreal antivascular endothelial growth factor, bevacizumab, for treatment of radiation optic neuropathy (RON). Methods and Materials: A prospective interventional clinical case series was performed of 14 patients with RON related to plaque radiotherapy for choroidal melanoma. The RON was characterized by optic disc edema, hemorrhages, microangiopathy, and neovascularization. The entry criteria included a subjective or objective loss of vision, coupled with findings of RON. The study subjects received a minimum of two initial injections of intravitreal bevacizumab (1.25 mg in 0.05 mL) every 6–8 weeks. The primary objectives included safety and tolerability. The secondary objectives included the efficacy as measured using the Early Treatment Diabetic Retinopathy Study chart for visual acuity, fundus photography, angiography, and optical coherence tomography/scanning laser ophthalmoscopy. Results: Reductions in optic disc hemorrhage and edema were noted in all patients. The visual acuity was stable or improved in 9 (64%) of the 14 patients. Of the 5 patients who had lost vision, 2 had relatively large posterior tumors, 1 had had the vision decrease because of intraocular hemorrhage, and 1 had developed optic atrophy. The fifth patient who lost vision was noncompliant. No treatment-related ocular or systemic side effects were observed. Conclusions: Intravitreal antivascular endothelial growth factor bevacizumab was tolerated and generally associated with improved vision, reduced papillary hemorrhage, and resolution of optic disc edema. Persistent optic disc neovascularization and fluorescein angiographic leakage were invariably noted. The results of the present study support additional evaluation of antivascular endothelial growth factor medications as treatment of RON.

  9. Antivascular Endothelial Growth Factor Bevacizumab for Radiation Optic Neuropathy: Secondary to Plaque Radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Finger, Paul T., E-mail: pfinger@eyecancer.com [New York Eye Cancer Center, New York, NY (United States); Chin, Kimberly J. [New York Eye Cancer Center, New York, NY (United States)

    2012-02-01

    Purpose: To evaluate the intravitreal antivascular endothelial growth factor, bevacizumab, for treatment of radiation optic neuropathy (RON). Methods and Materials: A prospective interventional clinical case series was performed of 14 patients with RON related to plaque radiotherapy for choroidal melanoma. The RON was characterized by optic disc edema, hemorrhages, microangiopathy, and neovascularization. The entry criteria included a subjective or objective loss of vision, coupled with findings of RON. The study subjects received a minimum of two initial injections of intravitreal bevacizumab (1.25 mg in 0.05 mL) every 6-8 weeks. The primary objectives included safety and tolerability. The secondary objectives included the efficacy as measured using the Early Treatment Diabetic Retinopathy Study chart for visual acuity, fundus photography, angiography, and optical coherence tomography/scanning laser ophthalmoscopy. Results: Reductions in optic disc hemorrhage and edema were noted in all patients. The visual acuity was stable or improved in 9 (64%) of the 14 patients. Of the 5 patients who had lost vision, 2 had relatively large posterior tumors, 1 had had the vision decrease because of intraocular hemorrhage, and 1 had developed optic atrophy. The fifth patient who lost vision was noncompliant. No treatment-related ocular or systemic side effects were observed. Conclusions: Intravitreal antivascular endothelial growth factor bevacizumab was tolerated and generally associated with improved vision, reduced papillary hemorrhage, and resolution of optic disc edema. Persistent optic disc neovascularization and fluorescein angiographic leakage were invariably noted. The results of the present study support additional evaluation of antivascular endothelial growth factor medications as treatment of RON.

  10. Simulation of the spectrum (Co-60), Theratron Equinox, using the code Penelope

    International Nuclear Information System (INIS)

    Quispe V, N. Y.; Ballon P, C. I.; Vega R, J. L. J.; Santos F, C.

    2017-10-01

    Using the code Penelope (Penetration and Energy Loss of Positrons and Electrons) V. 2008, the spectrum of the Theratron Equinox cobalt unit, currently used at the Goyeneche Hospital in Arequipa (Peru), was obtained in the radiotherapy service. The Penmain program was used to obtain the spectrum that, together with the PENGEOM package included in the Penelope code, allowed to build complex structures with, in this case, the cobalt unit head essentially comprising the cobalt source and its collimators. The dose-to-depth percentage curves were also obtained in different sizes of irradiated fields of 5 x 5, 10 x 10 and 15 x 15 cm 2 for the cobalt spectrum obtained, in which is observed that there is greater dispersion for fields greater and more time of simulation was needed, being concordance of the results of the simulation, when comparing the experimentally obtained data of the dose with the ionization chamber in a water tank. The spectrum obtained was validated with the data of the ionization chamber in the determination of dose-to-depth percentage curves; it can be used as a reference to optimize the radiotherapy planning system in the simulation with equivalent body materials. (Author)

  11. How radiation influences atherosclerotic plaque development. A biophysical approach in ApoE{sup -/-} mice

    Energy Technology Data Exchange (ETDEWEB)

    Kloosterman, Astrid; Dillen, Teun van; Dekkers, Fieke [National Institute for Public Health and the Environment (RIVM), Centre for Environmental Safety and Security, Bilthoven (Netherlands); Bijwaard, Harmen [National Institute for Public Health and the Environment (RIVM), Centre for Environmental Safety and Security, Bilthoven (Netherlands); Inholland University of Applied Sciences, Medical Technology Research Group, Haarlem (Netherlands); Heeneman, Sylvia [Maastricht University Medical Center, Experimental Vascular Pathology group, Department of Pathology, Cardiovascular Research Institute Maastricht (CARIM), Maastricht (Netherlands); Hoving, Saske; Stewart, Fiona A. [Netherlands Cancer Institute - Antoni van Leeuwenhoek Hospital, Division of Biological Stress Response (H3), Amsterdam (Netherlands)

    2017-11-15

    Atherosclerosis is the development of lipid-laden plaques in arteries and is nowadays considered as an inflammatory disease. It has been shown that high doses of ionizing radiation, as used in radiotherapy, can increase the risk of development or progression of atherosclerosis. To elucidate the effects of radiation on atherosclerosis, we propose a mathematical model to describe radiation-promoted plaque development. This model distinguishes itself from other models by combining plaque initiation and plaque growth, and by incorporating information from biological experiments. It is based on two consecutive processes: a probabilistic dose-dependent plaque initiation process, followed by deterministic plaque growth. As a proof of principle, experimental plaque size data from carotid arteries from irradiated ApoE{sup -/-} mice was used to illustrate how this model can provide insight into the underlying biological processes. This analysis supports the promoting role for radiation in plaque initiation, but the model can easily be extended to include dose-related effects on plaque growth if available experimental data would point in that direction. Moreover, the model could assist in designing future biological experiments on this research topic. Additional biological data such as plaque size data from chronically-irradiated mice or experimental data sets with a larger variety in biological parameters can help to further unravel the influence of radiation on plaque development. To the authors' knowledge, this is the first biophysical model that combines probabilistic and mechanistic modeling which uses experimental data to investigate the influence of radiation on plaque development. (orig.)

  12. Effect of cobalt-60 gamma-ray irradiation on beans (Phaseolus vulgaris L.) of huasteco variety

    International Nuclear Information System (INIS)

    Navarro A, W.

    1984-01-01

    Bean seeds, Huasteco variety, were irradiated at 10, 20, 30 and 40 kR in a cobalt-60 gamma-ray source. Non-irradiated seeds were used as control. Irradiated and non-irradiated seeds were planted under greenhouse conditions using a random design and a population of 200 plants per treatment for both first and second generations (M 1 and M 2 ). The characters studied were; germination, survival, morphological changes of leaves and stem, change in seed coat colour, flowering, height, stem diameter, number of internodes, number of pods and number of seeds per pod. General plant behaviour was also observed to detect changes on a genic or chromosomic level. (M.A.C.) [pt

  13. The Relation of Design Parameters, Plant Capacity and Processing Costs in Cobalt-60 Sterilization Plants

    International Nuclear Information System (INIS)

    Brown, M.G.

    1967-01-01

    The paper describes the main features of three basic types of cobalt-60 sterilization plants which have been designed to provide a complete range of capacities for radiosterilization of medical products. The smallest plant has a capacity of up to 50 000 cubic feet of medical products a year, the intermediate size plant has a capacity of up to 500 000 cubic feet a year, and the largest plant has a capacity in excess of 1000 000 cubic feet a year. The relations between capital costs, rate of production, efficiency and unit processing costs for each type of plant are discussed. The method of selecting the best type of plant for a particular need will also be outlined. (author)

  14. Cobalt sorption onto Savannah River Plant soils

    International Nuclear Information System (INIS)

    Hoeffner, S.L.

    1985-06-01

    A laboratory study of cobalt-60 sorption was conducted using Savannah River Plant soil and groundwater from the low-level waste burial ground. Systematic variation of soil and water composition indicates that cobalt sorption is most strongly a function of pH. Over a pH range of 2 to 9, the distribution coefficient ranged from 2 to more than 10,000 mL/g. Changes in clay content and in K + , Ca 2+ , or Mg 2+ concentrations influence cobalt sorption indirectly through the slight pH changes which result. The ions Na + , Cl - , and NO 3 - have no effect on cobalt sorption. Ferrous ion, added to groundwater to simulate the condition of water at the bottom of the waste trenches, accounts for part of the decrease in cobalt sorption observed with trench waters. 17 refs., 3 figs., 4 tabs

  15. Research and design of the moving system for the cobalt-60 industrial irradiator VINAGA2

    International Nuclear Information System (INIS)

    Le Minh Tuan; Tran Khac An; Nguyen Ngoc Phuong; Tran Van Hung; Cao Van Chung; Phan Phuoc Thang; Ha Thanh Viet; Nguyen Thanh Cuong; Nguyen Duc Hoa

    2017-01-01

    On the way of localization of Cobalt-60 industrial irradiators, Research and Development Center for Radiation Technology (VINAGAMMA) has successfully designed and manufactured the first version of Co-60 industrial irradiator, VINAGA1. The second version of Co-60 industrial irradiator has been studied and designed by VINAGAMMA in the frame of the scientific project No. DTCB.02/15/TTNCTK. The main system of a Co-60 industrial irradiator is a mechanical system inside an irradiation room namely a tote box moving system. This report presents the tote box moving system of VINAGA2 designed by VINAGAMMA. The tote box moving system contains 52 tote boxes with the dimensions of 50 cm (w) × 70 cm (l) × 150 cm (h) that are moving around the source racks in the manner of 4 passes and 2 levels. The irradiator VINAGA2 with this tote box moving system has good specifications: The minimum time of an irradiation cycle is 1 h 20 min. and the dose uniformity ratio (DUR) at the product densities of 0.1 g/cm 3 and 0.5 g/cm 3 is 1.4 and 1.8, respectively. Radiation energy utilization efficiency at the product densities of 0.1 g/cm 3 and 0.5 g/cm 3 is 19.7% and 48.8%, respectively. These specifications meet the requirements for a multi-purpose Co-60 industrial irradiator and the present irradiation requirements in Vietnam. (author)

  16. Development of a multichannel dosimeter for radiotherapy

    International Nuclear Information System (INIS)

    Menezes, Claudio Jose Mesquita

    2000-06-01

    In radiotherapy, verification of the patient dose is of great important for the success of the treatment. Uncertainties in the evaluation of this dose can produce serious complications such as the loss of the control of the disease and damage to normal tissue. Semiconductor detectors present advantages over other types of radiation detectors such as ionization chambers and thermoluminescent dosimeters including small dimensions, high sensitivity and fast response. In this work, a multichannel dosimetric system is linear with dose, for a 6 MV x-ray beam and also with a beam of cobalt-60 gamma rays. The coefficients of determination of the calibration curves were better then 0,9998 in all cases. The four sensors presented similar response with the dose for different field sizes. The variation of the response was smaller than 1%. In a related study, depth dose was measured, and the results showed a good agreement compared to theoretical values. The angular response of the detectors showed a variation of 7% for angles of 45 deg C. Using the Anderson Random phantom, dose at the isocenter was determined from measurements of the surface dose. From the results obtained it can be concluded that the dosimetric system developed is adequate for the evaluation of many parameters in radiation fields used in radiotherapy. This system can be used to measure the patient entrance dose under treatment conditions, and the equipment can be used in the radiotherapy quality assurance program. (author)

  17. Experiences on the implementation of a postal auditing service to know teletherapy doses using Cobalt 60 attained by the Secondary laboratory for dosimetric calibration from CPHR

    International Nuclear Information System (INIS)

    Campa, R.; Morales, J.A.; Molina, D.; Dominguez, L.

    1998-01-01

    This paper analyzes experiences gained by LSCD from CPHR on the implementation and validation of a postal auditing system. The system checks doses absorbed by water for teletherapy equipment using Cobalt 60. The verification was made with Chinese DTL type JR 1152F (microbars) introduced in capsules developed and employed by IAEA in the postal auditing service for doses IAEA/WHO. The analysis includes the creation of groups of detectors based on their individual sensibility. They have a dispersion range that was almost 2%. Here irradiation was applied to a water dummy. Other tests employed were that for thermal treatment and calibration. Besides one auditing the effectiveness of the postal technique in two facilities using Cobalt 60. The methodology implemented helps to determine doses absorbed in reference conditions with a lower global uncertainty (k=2) (3.2%)

  18. Cobalt

    Science.gov (United States)

    Slack, John F.; Kimball, Bryn E.; Shedd, Kim B.; Schulz, Klaus J.; DeYoung,, John H.; Seal, Robert R.; Bradley, Dwight C.

    2017-12-19

    Cobalt is a silvery gray metal that has diverse uses based on certain key properties, including ferromagnetism, hardness and wear-resistance when alloyed with other metals, low thermal and electrical conductivity, high melting point, multiple valences, and production of intense blue colors when combined with silica. Cobalt is used mostly in cathodes in rechargeable batteries and in superalloys for turbine engines in jet aircraft. Annual global cobalt consumption was approximately 75,000 metric tons in 2011; China, Japan, and the United States (in order of consumption amount) were the top three cobalt-consuming countries. In 2011, approximately 109,000 metric tons of recoverable cobalt was produced in ores, concentrates, and intermediate products from cobalt, copper, nickel, platinum-group-element (PGE), and zinc operations. The Democratic Republic of the Congo (Congo [Kinshasa]) was the principal source of mined cobalt globally (55 percent). The United States produced a negligible amount of byproduct cobalt as an intermediate product from a PGE mining and refining operation in southeastern Montana; no U.S. production was from mines in which cobalt was the principal commodity. China was the leading refiner of cobalt, and much of its production came from cobalt ores, concentrates, and partially refined materials imported from Congo (Kinshasa).The mineralogy of cobalt deposits is diverse and includes both primary (hypogene) and secondary (supergene) phases. Principal terrestrial (land-based) deposit types, which represent most of world’s cobalt mine production, include primary magmatic Ni-Cu(-Co-PGE) sulfides, primary and secondary stratiform sediment-hosted Cu-Co sulfides and oxides, and secondary Ni-Co laterites. Seven additional terrestrial deposit types are described in this chapter. The total terrestrial cobalt resource (reserves plus other resources) plus past production, where available, is calculated to be 25.5 million metric tons. Additional resources of

  19. Exposure buildup factors for a cobalt-60 point isotropic source for single and two layer slabs

    International Nuclear Information System (INIS)

    Chakarova, R.

    1992-01-01

    Exposure buildup factors for point isotropic cobalt-60 sources are calculated by the Monte Carlo method with statistical errors ranging from 1.5 to 7% for 1-5 mean free paths (mfp) thick water and iron single slabs and for 1 and 2 mfp iron layers followed by water layers 1-5 mfp thick. The computations take into account Compton scattering. The Monte Carlo data for single slab geometries are approximated by Geometric Progression formula. Kalos's formula using the calculated single slab buildup factors may be applied to reproduce the data for two-layered slabs. The presented results and discussion may help when choosing the manner in which the radiation field gamma irradiation units will be described. (author)

  20. Calculation of uncertainties in the protocol of dosimetry for Co 60 beams in Radiotherapy

    International Nuclear Information System (INIS)

    Velazquez M, S.; Carrera M, F.; Sanchez S, J.

    1998-01-01

    The objective in this work is to show how the uncertainty is possible to know in the determination of the absorbed dose in Co 60 photon beams and to establish in a rational form, tolerance levels for this. It is took as base the spanish protocol of dosimetry in Radiotherapy. We have been centered in a Co 60 beam. We utilized the statistical theory of little samples. We allowed to suggest a new approach about the treatment of the tolerance levels and the uncertainty of the measurement. After two years of experience in the practical hospitable application we have gotten to put around 1 % uncertainty in the absolute dosimetry of the Co 60 beam. The presented protocol allows to execute the accuracy requirements in the determination of absorbed doses. (Author)

  1. Effect of probiotics on the fecal microflora after radiotherapy: A pilot study

    Directory of Open Access Journals (Sweden)

    J Timko

    2013-01-01

    Full Text Available Background and Aim : The development of gastrointestinal symptoms following pelvic radiotherapy depends on morphological and functional modifications of the intestinal epithelium after radiation. The aim of this study was to evaluate and compare the effects of preventive administration of the preparation ′′5′′ Strain Dophilus and Hylak on the fecal microflora after radiotherapy in patients during radiotherapy. Materials and Methods : Fourteen patients were randomly selected and subdivided into two groups: The first group was administered ′′5′′ Strain Dophilus (L Group and the second group was administered Hylak (H Group. Radiation was delivered by a Cobalt 60 unit by using the four field box technique. The doses were divided into 2 Gy per day over 5 to 7 weeks to give the total cumulative dose of 50 Gy (2 Gy/day. High risk patients (e.g., patients with prostate cancer, received dosage 65 67 Gy (2 Gy/day. Results : Both experimental and clinical studies have shown that probiotics can effectively modulate intestinal inflammation by altering the composition and the metabolic and functional properties of gut indigenous flora. Conclusions : Many bacteria were found to be sensitive to irradiation. It would be necessary to check the possible effects of cytostatics on bacteria in larger studies.

  2. The use of an on-line computer system for radiotherapy planning. Part of a coordinated programme on computer applications in clinical dosimetry

    International Nuclear Information System (INIS)

    Tatcher, M.

    1977-07-01

    The aim of radiotherapy is to deliver a predetermined dose to the volume of a tumor in order to destroy it without at the same time harming healthy tissues nearby. The calculation of the dose distribution in a patient's body in order to determine the optimum arrangement of beam geometry is the central problem in treatment planning. For this task computers are increasingly being used as dose calculations by hand are time-consuming and exclude the application of modern treatment strategies. The objectives of this work were to set up a minimal departmental computer system for cobalt-60 radiotherapy treatment planning. Computer programmes were written for the following radiotherapy applications: Co-60 output charts (monthly charts of dose rate for determination of treatment time); interactive programme for calculating and optimizing isodose distributions to be used for treatment planning; calculation of irregular dose distributions of beams with arbitrary shape; gynecological radiotherapy, using internal Cs-137 and Ra-226 sources; linear isodose charts for 8 MV X-rays by interpolation from measured data. All programmes are written in BASIC. However, as BASIC does not link directly with the graphics devices, all programmes will be converted to FORTRAN, based on CUNNINGHAM's work. Although in principle the treatment planning programme in BASIC is satisfactory, it is not fast enough to replace manual calculations. Routine interactive computerized treatment planning will be possible once the FORTRAN programmes are operational. For all other routine purposes the BASIC radiotherapy programmes are suitable

  3. Histological analysis of the alterations on cortical bone channels network after radiotherapy: A rabbit study.

    Science.gov (United States)

    Rabelo, Gustavo Davi; Beletti, Marcelo Emílio; Dechichi, Paula

    2010-10-01

    The aim of this study was to evaluate the effects of radiotherapy in cortical bone channels network. Fourteen rabbits were divided in two groups and test group received single dose of 15 Gy cobalt-60 radiation in tibia, bilaterally. The animals were sacrificed and a segment of tibia was removed and histologically processed. Histological images were taken and had their bone channels segmented and called regions of interest (ROI). Images were analyzed through developed algorithms using the SCILAB mathematical environment, getting percentage of bone matrix, ROI areas, ROI perimeters, their standard deviations and Lacunarity. The osteocytes and empty lacunae were also counted. Data were evaluated using Kolmogorov-Smirnov, Mann Whitney, and Student's t test (P < 0.05). Significant differences in bone matrix percentage, area and perimeters of the channels, their respective standard deviations and lacunarity were found between groups. In conclusion, the radiotherapy causes reduction of bone matrix and modifies the morphology of bone channels network. © 2010 Wiley-Liss, Inc.

  4. Sterilization of silver acidium pipemedicum skin for the treatment of burns by radioactive cobalt-60-γray

    International Nuclear Information System (INIS)

    Zeng Defeng; Cao Fengsheng; Chen Qinglong; Li Guohui; Su Ziyi; Cao Yong; Wu Wenqing; Qiu Zeyi; Chen Zhanxian

    1995-01-01

    The radiated silver acidum pipemedicum skin (RSAPS) was made of 0.4-0.8mm laminal skin from healthy white pig, which was infiltrated in norfloxacin and silver nitrate, packed with the filkm bag of alummium poil and radiated by cobalt-60γ-ray for sterilization at the dosage of 27.92-35.31Gy/min for a total dose of 25KGY, RSAPS was very effective in sterilization and had no bad effect on elasticity, adhesion, water permeability, and structure of pig skin. So it is highly appreciated by the patients and medical personnel for its convenience of usage and has gained good social and economic beneficial results. (Author)

  5. Brainstem tolerance to conformal radiotherapy of skull base tumors

    International Nuclear Information System (INIS)

    Debus, J.; Hug, E.B.; Munzenrider, J.E.; Liebsch, N.J.; O'Farrell, D.; Efird, J.; Daly, W.; Suit, H.D.

    1996-01-01

    Purpose/Objective: Brainstem tolerance to inhomogenous radiation doses applied by modern conformal radiotherapy has not yet been examined. The aim of this study was to analyse the incidence of brainstem toxicity in patients treated for skull base tumors with high dose conformal radiotherapy. Materials and Methods: Between 1974 and 1995, 367 patients with chordomas (n=195) and chondrosarcomas (n=172) of the base of skull have been treated with combined megavoltage photon and 160 MeV proton radiotherapy. All patients had previously undergone biopsy, subtotal or total tumor removal. 104 patients had two or more surgical procedures before radiotherapy. Following 3D treatment planning with delineation of target volumes and critical non-target structures, dose distributions and dose volume histograms were calculated [at the time of treatment delivery]. Radiotherapy was given once a day, 1.8 Gy or CGE (Cobalt Gy Equivalent: Proton Gy X 1.1) per fraction, 5 fractions per week, with prescribed target doses ranging from 63 CGE to 79.2 CGE (mean = 67.8 CGE). Doses to the brainstem surface were limited to ≤64 CGE and to the brainstem center to ≤53 CGE. Dose distributions were developed to limit dose to brainstem surface and center; current plans limit dose to surface and center to ≤64 CGE and ≤53 CGE, respectively. Brainstem toxicity was scored according to the RTOG grading system. Results: Follow-up ranged from 6 months to 21.4 years (mean = 42.5 months). Brainstem symptoms, attributable to the treatment, developed in 17 of 282 patients with local tumor control (6.0%), resulting in death of three patients. The mean time to onset of symptoms was 17 months (range: 4.5 to 177 months). These symptoms appeared in 89.5% within 3 years. Grading of the brainstem toxicity is listed in table 1. Actuarial rates of 5 and 10 year toxicity free survival were 87% and 82% respectively. Increased risk of brainstem toxicity was significantly associated with maximum brainstem dose

  6. Salivary flow rate and pH after radiotherapy of the head and neck region

    International Nuclear Information System (INIS)

    Lima, Antonio Adilson Soares de; Figueiredo, Maria Antonia Zancanaro de; Krapf, Stella Maria Rigo; Souza, Fabiany Rodrigues de

    2004-01-01

    The most common sequelae in head and neck cancer patients submitted to radiotherapy (60Cobalt) is postirradiation hypo salivation. This leads to a change in oral physiology, and, as a consequence, the irradiated individual is susceptible to infections and caries lesions. The aim of this study was to evaluate the behaviour of stimulated whole saliva flow rate (SWSFR) during and after radiotherapy treatment for head and neck cancer by lateral opposed fields. Six samples of mechanically stimulated whole saliva were collected of each individual and evaluated by gravimetric method.The first sample was collected before radiotherapy; the second one after 1500 cGy dose; the third one after the last dose of treatment and the remainder samples in intervals of subsequent two months up to six months after the end of treatment. The SWSFR decreased in 50% after a dose of 1500 cGy (1/4 of received treatment). After radiation therapy, the SWSFR was 0,33 ml/min and after six months was 0,20 ml/min. These values represented, respectively, a decreasing in 64% and 78% of initial values (ANOVA, Tukey's Test p<0.05).Based in these results, the authors concluded radiotherapy when applied in malign neoplasms of the head and neck region by lateral opposed fields was able to decrease significantly salivary flow rate. Intensive preventive dental care during and after radiotherapy seems to be an useful tool to avoid radiation caries and their complications. (author)

  7. Effect of cyanide on the distribution of 60Co in mice

    International Nuclear Information System (INIS)

    Frankenberg, L.

    1982-01-01

    The effect of cyanide on the distribution of cobalt was studied by injecting mice i.p. with potassium cyanide 61.4 μmoles/kg, followed 1 min later by 60 CoCl 2 38.5 μmoles/kg i.v. Blood and tissue concentrations of 60 Co were then determined up to 48 h after injection and the results were compared with those obtained from control animals receiving 60 CoCl 2 only. In animals treated with cobalt plus cyanide, considerably higher concentrations of 60 Co were found in the spleen in comparison with controls during the whole observation period, whereas the 60 Co concentration in the pancreas was lower than that of controls during the first 4 h. In other tissues no significant differences between cyanide-treated animals and controls were noticed. Determination of complex-bound cyanide demonstrated that the increased uptake of cobalt in the spleen observed in cyanide-treated animals was due to cobalt-cyanide complex(es). Cyanide did not affect the plasma protein binding of cobalt. (orig.)

  8. The spanish radiotherapy park: past and present

    International Nuclear Information System (INIS)

    Tormo Ferrero, Manuel J.

    2001-01-01

    The present article has as objective to provide a general overview on the spanish radiotherapy park, presenting how was its start and evolution until the current state. Considering only the units of teletherapy and the accelerators. Actually in Spain there is 28 units of Cobalt therapy, in functioning during the last two decades, being advised a rapid substitution to accelerators

  9. In vivo and in vitro experimental study on cervix cancer with combination of HSV-TK/GCV suicide gene therapy system and 60Co radiotherapy

    International Nuclear Information System (INIS)

    Chen Daozhen; Xue Wenqun; Zhan Huiying; Zhu Yunxia; Yang Youyi; Liu Lu; Tang Qiusha

    2006-01-01

    Objective: To evaluate the killing effect of HSV-TK/GCV suicide gene therapy system combined with 60 Co radiotherapy on human cervical cancer HeLa cell line in vivo and in vitro, and to explore radiosensitization by the HSV-TK/GCV system. Methods: The HSV-TK/GCV suicide gene therapy system and 60 Co radiotherapy were used separately or in combination for human cervical cancer HeLa cell line in vivo and in vitro to compare their effects. Colony formation test and the rate of radiosensitization effect(E/O) were employed to observed the radiosensitization by the HSV-TK/GCV system. Results: The HSV-TK/GCV suicide gene therapy system showed strong therapeutic effects on HeLa cells both in vitro and in vivo (the inhibition rates were 45.8% and 39.5%, respectively). Moreover, the combined application of gene therapy and radiotherapy exhibited stronger therapeutic effects in vitro and in vivo (the inhibition rate was 87.5% in vitro, and was 87.9% in vivo) (P 1.4), indicating the HSV-TK/GCV system could exert a sensitizing effect on 60 Co radiotherapy of the transplanted human cervical cancer cells in nude mice. Conclusion: The HSV-TK/GCV system has radiosensitizationaction. Gene therapy combined with radiotherapy may be a good supplementary method for synthetic treatment of cervical cancer. (authors)

  10. Effects of intensity-modulated radiotherapy on human oral microflora

    International Nuclear Information System (INIS)

    Shao Ziyang; Tang Zisheng; Jiang Yuntao; Ma Rui; Liu Zheng; Huang Zhengwei; Yan Chao

    2011-01-01

    This study aimed to evaluate changes in the biodiversity of the oral microflora of patients with head and neck cancer treated with postoperative intensity-modulated radiotherapy (IMRT) or conventional radiotherapy (CRT). Pooled dental plaque samples were collected during the radiation treatment from patients receiving IMRT (n=13) and CRT (n=12). Denaturing gradient gel electrophoresis (DGGE) was used to analyze the temporal variation of these plaque samples. The stimulated and unstimulated salivary flow rates were also compared between IMRT and CRT patients. Reductions in the severity of hyposalivation were observed in IMRT patients compared with CRT patients. We also observed that the temporal stability of the oral ecosystem was significantly higher in the IMRT group (69.96±7.82%) than in the CRT group (51.98±10.45%) (P<0.05). The findings of the present study suggest that IMRT is more conducive to maintaining the relative stability of the oral ecosystem than CRT. (author)

  11. Self-powered in-core detectors of cobalt type

    International Nuclear Information System (INIS)

    Jonsson, Georg

    1975-01-01

    Testing and development of self-powered neutron detectors with a cobalt emitter is described. Long term irradiation at 400 deg C is expected to indicate insulation quality, change in calibration and 60 Co build-up. Dynamic tests to investigate possible transient effects due to temperature changes are being performed on a number of detectors up to about 600 deg C. A long term irradiation at low temperature has been terminated after 4.5 years. On completion, neutron dose was estimated to be 5.6 x 10 21 nvt and the 60 Co background was 9.3 % of the full flux signal. A recently introduced long term test is expected to provide data on instability effects due to 61 Co. For a BWR in-core detector installation, the main advantage of cobalt detectors, apart from the small size, appears to be long life. Development work is being done on detectors with vanadium-cobalt emitters, electronic separation of fast and delayed signals and reduction of gamma sensitivity. (O.T.)

  12. Radiation related complications after ruthenium plaque radiotherapy of uveal melanoma

    Energy Technology Data Exchange (ETDEWEB)

    Summanen, P.; Immonen, I.; Kivela, T.; Tommila, P.; Tarkkanen, A. [Helsinki Univ. Central Hospital (Finland). Meilahti Clinic; Heikkonen, J. [Helsinki Univ. (Finland). Dept of Radiotherapy and Oncology

    1996-08-01

    The aims were to analyse radiation related complications and secondary enucleation after irradiation of malignant uveal melanoma with ruthenium-106 plaques. A series of 100 consecutive eyes irradiated in 1981-91 was analysed using the life table method and the Cox proportional hazards model. The 3 and 5 year probabilities of being without radiation cataract were 73% and 63%, without neovascular glaucoma 91% and 81%, without vitreous haemorrhage 83% and 74%, without radiation maculopathy 85% and 70%, and without radiation optic neuropathy 90% and 88%, respectively. (Author).

  13. Radiation related complications after ruthenium plaque radiotherapy of uveal melanoma

    International Nuclear Information System (INIS)

    Summanen, P.; Immonen, I.; Kivela, T.; Tommila, P.; Tarkkanen, A.; Heikkonen, J.

    1996-01-01

    The aims were to analyse radiation related complications and secondary enucleation after irradiation of malignant uveal melanoma with ruthenium-106 plaques. A series of 100 consecutive eyes irradiated in 1981-91 was analysed using the life table method and the Cox proportional hazards model. The 3 and 5 year probabilities of being without radiation cataract were 73% and 63%, without neovascular glaucoma 91% and 81%, without vitreous haemorrhage 83% and 74%, without radiation maculopathy 85% and 70%, and without radiation optic neuropathy 90% and 88%, respectively. (Author)

  14. Results of the application of the Risk Evaluation System in Radiotherapy (RESRA) in radiotherapy facilities in Mexico

    International Nuclear Information System (INIS)

    Paz G, A.; Godinez S, V.

    2013-10-01

    The present work describes the main results of the risk evaluation for some radiotherapy treatments with lineal accelerators, cobalt 60, brachytherapy of high dose rate and brachytherapy of low dose rate that are realize in Mexico. These evaluations were carried out applying the risk matrices method with the tool computer risk evaluation system in radiotherapy, accessible for the national users through internet, and developed by the Comision Nacional de Seguridad Nuclear y Salvaguardias in Mexico, in cooperation with the Forum of Ibero-American regulators. The used methodology is based on the risk matrices method that is a mathematical tool for the risk evaluation, and it was centered in the evaluation from the risk to which are exposed the patients, the occupational exposed personnel and people in general, by the mechanical faults of the treatment equipment s, bad calibrations, human errors, or any other event initiator of accidents. The events initiators of accidents are defined as those undesirable events that can produce and administration of an excessive dose or a sub-dose of the prescribed dose by the doctor, to the planned objective volume, or undesirable dose to the patient's regions or dose to occupational exposed personnel or people in general. The barriers are the actions and systems as mechanical switches, interlocks or alarms, dedicated to avoid that these accidents take place. The evaluation analysis of the risk developed by the members of the Forum for radiotherapy facilities together with the software RESRA has demonstrated to be useful in the prevention of many possible accidents that have happened in the past in other facilities and can avoid many others in the future. (Author)

  15. Cobalt-free nickel-base superalloys

    International Nuclear Information System (INIS)

    Koizumi, Yutaka; Yamazaki, Michio; Harada, Hiroshi

    1979-01-01

    Cobalt-free nickel-base cast superalloys have been developed. Cobalt is considered to be a beneficial element to strengthen the alloys but should be eliminated in alloys to be used for direct cycle helium turbine driven by helium gas from HTGR (high temp. gas reactor). The elimination of cobalt is required to avoid the formation of radioactive 60 Co from the debris or scales of the alloys. Cobalt-free alloys are also desirable from another viewpoint, i.e. recently the shortage of the element has become a serious problem in industry. Cobalt-free Mar-M200 type alloys modified by the additions of 0.15 - 0.2 wt% B and 1 - 1.5 wt% Hf were found to have a creep rupture strength superior or comparable to that of the original Mar-M200 alloy bearing cobalt. The ductility in tensile test at 800 0 C, as cast or after prolonged heating at 900 0 C (the tensile test was done without removing the surface layer affected by the heating), was also improved by the additions of 0.15 - 0.2% B and 1 - 1.5% Hf. The morphology of grain boundaries became intricated by the additions of 0.15 - 0.2% B and 1 - 1.5% Hf, to such a degree that one can hardly distinguish grain boundaries by microscopes. The change in the grain boundary morphology was considered, as suggested previously by one of the authors (M.Y.), to be the reason for the improvements in the creep rupture strength and tensile ductility. (author)

  16. HAW simulation experiments with cobalt-60 radiation sources in the Asse salt mine

    International Nuclear Information System (INIS)

    Rothfuchs, T.; Wieczorek, K.; Feddersen, H.K.

    1986-01-01

    The report describes the experimental work and the measured data of the joint German-American project for the HAW simulation experiment with cobalt-60 radiation sources in the Asse salt mine, covering the period up to the end of the third quarter 1986. The experiment is intended to yield information on the synergistic effects of heat and ionizing radiation on the salt rock under representative waste repository conditions. The investigations aim at the migration, release, and radiolytic decomposition of the water and gas components in the rock salt, and at the thermally induced strain and deformation processes. In addition, corrosion tests are planned to be made on various container test materials, and analyses of salt rock core samples for assessing the effect of heat and radiation on the rock. The report in hand presents all data obtained during the experiment. The results of the subsequent evaluation and verification studies will be presented in another report, the programme being given in an annex to the report in hand. (orig./RB) [de

  17. The dosimetry of cobalt-60 γ-ray total body irradiation before bone marrow transplantation

    International Nuclear Information System (INIS)

    Dong Fan; Zhang Guiru

    1989-11-01

    The dosimetric considerations of using conventional cobalt-60 unit total body irradiation (TBI) are presented. By extending the source-to-midplane distance (SMD) to 346 cm, a 92 x 98 cm 2 rectangular field with diagonal dimension 134 cm was obtained. The results from the phantom measurements showed: (1) the effective field corresponding to an average-size patient is 25 x 25 cm 2 , and a method for estimating the effective field of human body is given; (2) the midplane doses are consistently higher than those of surfaces, but the dose ratio of midplane to surface decreases as the body thickness increases, and a significant negative correlation is existed between the dose ratio and thickness, thus a linear regression line is fitted; (3) the anterior-posterior (AP) or AP + bilateral irradiation will yield a more uniform dose distribution in the whole body than the bilateral irradiation; (4) the dose uniformity can apparently be improved by the tissue compensation, for which the technique is described

  18. An analysis of cobalt irradiation in CANDU 6 reactor core

    International Nuclear Information System (INIS)

    Gugiu, E.D.; Dumitrache, I.

    2003-01-01

    In CANDU reactors, one has the ability to replace the stainless steel adjuster rods with neutronically equivalent Co assemblies with a minimum impact on the power plant safety and efficiency. The 60 Co produced by 59 Co irradiation is used extensively in medicine and industry. The paper mainly describes some of the reactor physics and safety requirements that must be carried into practice for the Co adjuster rods. The computations related to the neutronically equivalence of the stainless steel adjusters with the Co adjuster assemblies, as well as the estimations of the activity and the heating of the irradiated cobalt rods are performed using the Monte Carlo codes MCNP5 and MONTEBURNS2.1. The 60 Co activity and heating evaluations are closely related to the neutronics computations and to the density evolution of cobalt isotopes during assumed in-core irradiation period. Unfortunately, the activities of these isotopes could not be evaluated directly using the burn-up capabilities of the MONTEBURNS code because of the lack of their neutron cross-section from the MCNP5 code library. Additional MCNP5 runs for all the cobalt assemblies have been done in order to compute the flux-spectrum, the 59 Co and the 60 Co radiative capture reaction rates in the adjusters. The 60m Co cross-section was estimated using the flux-spectrum and the ORIGEN2.1 code capabilities THERM and RES. These computational steps allowed the evaluation of the one-group cross-section for the radiative capture reactions of cobalt isotopes. The values obtained replaced the corresponding ones from the ORIGEN library, which have been estimated using the flux-spectrum specific to the fuel. The activity values are used to evaluate the dose at the surface of the device designed to transport the cobalt adjusters. (authors)

  19. Dosimetry on the radiological risks prevention in radiotherapy

    International Nuclear Information System (INIS)

    Fornet R, O. M.; Perez G, F.

    2014-08-01

    Dosimetry in its various forms plays a determining role on the radiological risks prevention in radiotherapy. To prove this in this paper is shown an analysis based on the risk matrix method, how the dosimetry can influence in each stages of a radiotherapy service; installation and acceptance, operation, maintenance and calibration. For each one of these stages the role that can play is analyzed as either the initiating event of a radiological accident or limiting barrier of these events of the dosimetric processes used for the individual dosimetry, the area monitoring, fixed or portable, for radiation beam dosimetry and of the patients for a radiotherapy service with cobalt-therapy equipment. The result of the study shows that the application of a prospective approach in the role evaluation of dosimetry in the prevention and mitigation of the consequences of a radiological accident in radiotherapy is crucial and should be subject to permanent evaluation at each development stage of these services. (author)

  20. Manganese substituted cobalt ferrite magnetostrictive materials for magnetic stress sensor applications

    OpenAIRE

    Paulsen, J. A.; Ring, A. P.; Lo, C. C. H.; Snyder, John Evan; Jiles, David

    2005-01-01

    Metal bonded cobalt ferrite composites have been shown to be promising candidate materials for use in magnetoelastic stress sensors, due to their large magnetostriction and high sensitivity of magnetization to stress. However previous results have shown that below 60 °C the cobalt ferrite material exhibits substantial magnetomechanical hysteresis. In the current study, measurements indicate that substituting Mn for some of the Fe in the cobalt ferrite can lower the Curie temperature of the ma...

  1. Cobalt deposition studies in the primary circuit under BWR conditions (Phase 1 and 2)

    International Nuclear Information System (INIS)

    Bennett, Peter

    1996-04-01

    This report presents the results from the first 2 phases of an experiment performed to investigate the effects of water chemistry on cobalt transport and deposition in the primary circuit under BWR conditions. Two high pressure water loops have been used to compare the incorporation of cobalt into the oxide films on coupons of various LWR primary circuit constructional materials, with several pretreatments, under Hydrogen Water Chemistry (HWC) and Normal Water Chemistry (NWC) conditions. Cobalt-60 deposition rates onto samples that had been pre-oxidised in air were lower than on samples that had been exposed previously in a water loop or had untreated surfaces. In NWC, oxide layers were thicker, normalised Co-60 deposition rates were higher and Co-60 activities per unit volume of oxide were greater. Some evidence has been produced to support the conclusions of other workers that a chromium-rich outer oxide layer is responsible for enhanced cobalt incorporation. (author)

  2. Cobalt toxicity: Chemical and radiological combined effects on HaCaT keratinocyte cell line

    International Nuclear Information System (INIS)

    Sandre, C.; Moulin, C.; Bresson, C.; Gault, N.; Poncy, J. L.; Lefaix, J. L.

    2010-01-01

    Cobalt (Co) is an essential trace element well known as a constituent of vitamin B 12 , but different compounds of Co are also described as highly toxic and/or radio-toxic for individuals or the environment. In nuclear power plants, 58 Co and 60 Co are radioactive isotopes of cobalt present as activation products of stable Co and Ni used in alloys. Skin exposure is a current occupational risk in the hard metal and nuclear industries. As biochemical and molecular cobalt-induced toxicological mechanisms are not fully identified, we investigated cobalt toxicity in a model human keratinocyte cell line, HaCaT. In this study, we propose a model to determine the in vitro chemical impact on cell viability of a soluble form of cobalt (CoCl 2 ) with or without gamma-ray doses to mimic contamination by 60 Co, to elucidate the mechanisms of cobalt intracellular chemical and radiological toxicity. Intracellular cobalt concentration was determined after HaCaT cell contamination and chemical toxicity was evaluated in terms of cellular viability and clonogenic survival. We investigated damage to DNA in HaCaT cells by combined treatment with chemical cobalt and a moderate gamma-ray dose. Additive effects of cobalt and irradiation were demonstrated. The underlying mechanism of cobalt toxicity is not clearly established, but our results seem to indicate that the toxicity of Co(II) and of irradiation arises from production of reactive oxygen species. (authors)

  3. Cobalt toxicity: Chemical and radiological combined effects on HaCaT keratinocyte cell line

    Energy Technology Data Exchange (ETDEWEB)

    Gault, N. [CEA Fontenay aux Roses, DSV/IRCM/SCSR/LRTS, 92265 Fontenay aux Rose (France); Sandre, C.; Moulin, B.; Bresson, C. [CEA, DEN, SECR, Laboratoire de Speciation des Radionucleides et des Molecules, F-91191 Gif-sur-Yvette (France); Poncy, J.L. [CEA Bruyeres Le Chatel, DSV/IRCM/SREIT/LRT, 91680 Bruyeres Le Chatel (France); Lefaix, J.L. [CEA Caen, DSV/IRCM/SRO/LARIA, 14070 Caen (France)

    2010-07-01

    Cobalt (Co) is an essential trace element well known as a constituent of vitamin B12, but different compounds of Co are also described as highly toxic and/or radio-toxic for individuals or the environment. In nuclear power plants, {sup 58}Co and {sup 60}Co are radioactive isotopes of cobalt present as activation products of stable Co and Ni used in alloys. Skin exposure is a current occupational risk in the hard metal and nuclear industries. As biochemical and molecular cobalt-induced toxicological mechanisms are not fully identified, we investigated cobalt toxicity in a model human keratinocyte cell line, HaCaT. In this study, we propose a model to determine the in vitro chemical impact on cell viability of a soluble form of cobalt (CoCl{sub 2}) with or without {gamma}-ray doses to mimic contamination by {sup 60}Co, to elucidate the mechanisms of cobalt intracellular chemical and radiological toxicity. Intracellular cobalt concentration was determined after HaCaT cell contamination and chemical toxicity was evaluated in terms of cellular viability and clonogenic survival. We investigated damage to DNA in HaCaT cells by combined treatment with chemical cobalt and a moderate {gamma}-ray dose. Additive effects of cobalt and irradiation were demonstrated. The underlying mechanism of cobalt toxicity is not clearly established, but our results seem to indicate that the toxicity of Co(II) and of irradiation arises from production of reactive oxygen species. (authors)

  4. Cobalt toxicity: Chemical and radiological combined effects on HaCaT keratinocyte cell line

    Energy Technology Data Exchange (ETDEWEB)

    Sandre, C.; Moulin, C.; Bresson, C. [CEA Saclay, DEN, SECR, Lab Speciat Radionucleides and Mol, F-91191 Gif Sur Yvette (France); Gault, N. [CEA Fontenay Roses, DSV IRCM SCSR LRTS, F-92265 Fontenay Aux Roses (France); Poncy, J. L. [CEA Bruyeres Le Chatel, DSV IRCM SREIT LRT, F-91680 Bruyeres Le Chatel (France); Lefaix, J. L. [CEA Caen, DSV IRCM SRO LARIA, F-14070 Caen (France)

    2010-07-01

    Cobalt (Co) is an essential trace element well known as a constituent of vitamin B{sub 12}, but different compounds of Co are also described as highly toxic and/or radio-toxic for individuals or the environment. In nuclear power plants, {sup 58}Co and {sup 60}Co are radioactive isotopes of cobalt present as activation products of stable Co and Ni used in alloys. Skin exposure is a current occupational risk in the hard metal and nuclear industries. As biochemical and molecular cobalt-induced toxicological mechanisms are not fully identified, we investigated cobalt toxicity in a model human keratinocyte cell line, HaCaT. In this study, we propose a model to determine the in vitro chemical impact on cell viability of a soluble form of cobalt (CoCl{sub 2}) with or without gamma-ray doses to mimic contamination by {sup 60}Co, to elucidate the mechanisms of cobalt intracellular chemical and radiological toxicity. Intracellular cobalt concentration was determined after HaCaT cell contamination and chemical toxicity was evaluated in terms of cellular viability and clonogenic survival. We investigated damage to DNA in HaCaT cells by combined treatment with chemical cobalt and a moderate gamma-ray dose. Additive effects of cobalt and irradiation were demonstrated. The underlying mechanism of cobalt toxicity is not clearly established, but our results seem to indicate that the toxicity of Co(II) and of irradiation arises from production of reactive oxygen species. (authors)

  5. Description and operation of GATRI

    International Nuclear Information System (INIS)

    Izard, M.E.

    1985-01-01

    The gamma technology research irradiator (GATRI) is a cobalt-60 gamma irradiator suitable for research and development projects and small scale industrial applications. Cobalt rods and discs can be arranged as a line or plaque source and dose rates may be selected by changing the source load, source to target distance, or by placing shielding between the source and target

  6. Automation of the Calibration of Reference Dosimeters Used in Radiotherapy

    International Nuclear Information System (INIS)

    Romero Acosta, A.; Gutierrez Lores, S.

    2013-01-01

    Traceability, accuracy and consistency of radiation measurements are essential in radiation dosimetry, particularly in radiotherapy, where the outcome of treatments is highly dependent on the radiation dose delivered to patients. The role of Secondary Standard Dosimetry Laboratories (SSDLs) is crucial in providing traceable calibrations to hospitals, since these laboratories disseminate calibrations at specific radiation qualities appropriate to the use of radiation measuring instruments. These laboratories follow IAEA/WHO guidelines for calibration procedures, often being current and charge measurements described in these guidelines a tedious task. However, these measurements are usually done using modern electrometers which are equipped with a RS-232 interface that allows instrument control from a PC. This paper presents the design and employment of an automated system aimed to the measurements of the radiotherapy dosimeters calibration process for Cobalt-60 gamma rays. A software was developed using Lab View, in order to achieve the acquisition of the charge values measured, calculation of the calibration coefficient and issue of a calibration certificate. A primary data report file is filled and stored in the PC's hard disk. By using this software tool, a better control over the calibration process is achieved, it reduces the need for human intervention and it also reduces the exposure of the laboratory staff. The automated system has been used for the calibration of reference dosimeters used in radiotherapy at the Cuban Secondary Standard Dosimetry Laboratory of the Center for Radiation Protection and Hygiene (Author)

  7. Perturbation of cobalt 60 radiation doses by metal objects implanted during oral and maxillofacial surgery

    International Nuclear Information System (INIS)

    Tatcher, M.; Kuten, A.; Helman, J.; Laufer, D.

    1984-01-01

    The influence on cobalt 60 dose distributions of typical metal parts used in oral and maxillofacial surgery was studied. Relative doses were determined by exposing x-ray films in a polystyrene phantom set-up containing samples of vitallium, titanium, and stainless steel. Optical densities were converted to doses with the aid of sensitometric curves. The results show that for normal incidence there is a 25% to 40% increase in dose at the entrance side of the metal and a 20% to 25% decrease in dose at the exit side. The enhancement effect falls off rapidly and becomes negligible at about 1 mm from the interface. The reduction effect decreases more gradually and is still evident at distances of a few centimeters. These dose perturbations should be taken into account in the planning of radiation therapy for patients in whom metal objects have been implanted

  8. Extension of the Commonwealth standard of absorbed dose from cobalt-60 energy to 25 MV

    International Nuclear Information System (INIS)

    Sherlock, S.L.

    1986-01-01

    With the introduction of high energy linear accelerators in hospitals, there is a need for direct measurement of absorbed dose for energies to 25 MV for photons and 20 MeV electrons. The present Australian standard for absorbed dose at cobalt-60 energy is a graphite micro-calorimeter maintained at the AAEC Lucas Heights Research Laboratories. A thorough theoretical analysis of calorimeter operation suggests that computer control and monitoring techniques are appropriate. Solution of Newton's law of cooling for a four-body calorimeter allows development of a computer simulation model. Different temperature control algorithms may then be run and assessed using this model. In particular, the application of a simple differencer is examined. Successful implementation of the calorimeter for energies up to 25 MV could lead to the introduction of an Australian absorbed dose protocol based on calorimetry, therby reducing the uncertainties associated with exposure-based protocols

  9. Uptake of cobalt-60 from sea water and from labelled food by the common shrimp Crangon erangon (L.)

    International Nuclear Information System (INIS)

    Weers, A.W. van

    1975-01-01

    The role of two different modes of uptake in the accumulation of 60 Co by the common shrimp (Crangon crangon (L.)) is the subject of the present study. The results show that accumulation of 60 Co from sea water is a slow process. The concentration factor for whole animals reached in one month was only about 13. Most of the activity accumulated from water appears to be associated with the exoskeleton. As a consequence, moulting has a pronounced effect on the uptake pattern of 60 Co and on the subsequent retention of the radionuclide by shrimps kept in non-radioactive sea water. After single feeding of shrimps with labelled mussel flesh, 60 Co is retained according to an exponential function with a short-lived and a long-lived component. The short-lived component has a mean biological half-life of 1.2 days and accounts for about 80% of the initial activity. About 20% of the initial activity is lost with a mean biological half-life of about 10 days. After repeated feeding of labelled mussel flesh the short-lived component in the 60 Co retention is virtually absent. Cobalt-60 taken up with food is localized mainly in the digestive gland and the concentration in the edible muscles from the abdomen is relatively small. It is concluded from the present study that direct uptake from sea water will play only a minor role in the accumulation of 60 Co in the internal organs of the shrimp. 60 Co released into the marine environment will be taken up by shrimps mainly from food. The results indicate a rapid turnover of 60 Co in shrimps. (author)

  10. Estimation of uranium and cobalt-60 distribution coefficients and uranium-235 enrichment at the Combustion Engineering Company site in Windsor, Connecticut

    International Nuclear Information System (INIS)

    Wang, Y.; Orlandini, K.A.; Yu, C.

    1996-05-01

    Site-specific distribution coefficients for uranium isotopes and cobalt-60 (Co-60) and the fraction of uranium-235 (U-235) enrichment by mass were estimated for environmental samples collected from the Combustion Engineering Company site in Windsor, CT. This site has been identified for remedial action under the US Department of Energy's (DOE) Formerly Utilized Sites Remedial Action Program. The authority of DOE at the Combustion Engineering site is limited to (1) Building 3; (2) other activities or areas associated exclusively with Building 3 (such as sewer lines); or (3) contamination that is exclusively highly enriched uranium. In this study, 16 samples were collected from the Combustion Engineering site, including 8 soil, 4 sediment, 3 water, and 1 water plus sludge sample. These samples were analyzed for isotopic uranium by alpha spectrometry and for Co-60 by gamma spectrometry. The site-specific distribution coefficient for each isotope was estimated as the ratio of extractable radionuclide activity in the solid phase to the activity in the contact solution following a 19-day equilibration. The uranium activity measurements indicate that uranium-234 (U-234) and uranium-238 (U-238) were in secular equilibrium in two soil samples and that soil and sediment samples collected from other sampling locations had higher U-234 activity than U-238 activity in both the solid and solution phases. The site-specific distribution coefficient (Kd) ranged from 82 to 44,600 mL/g for U-238 and from 102 to 65,900 mL/g for U-234. Calculation of U-235 enrichment by mass indicated that four soil samples had values greater than 0.20; these values were 0.37, 0.38, 0.46, and 0.68. Cobalt-60 activity was detected in only three sediment samples. The measured Co-60 activity in the solid phase ranged from 0.15 to 0.45 pCi/g and that in the water phase of all three samples combined was 4 pCi/L. The Kd value for Co-60 in the site brook sediment was calculated to be 70 mL/g

  11. No Calcium-Fluoride-Like Deposits Detected in Plaque Shortly after a Sodium Fluoride Mouthrinse

    OpenAIRE

    Vogel, G.L.; Tenuta, L.M.A.; Schumacher, G.E.; Chow, L.C.

    2010-01-01

    Plaque ‘calcium-fluoride-like’ (CaF2-like) and fluoride deposits held by biological/bacterial calcium fluoride (Ca-F) bonds appear to be the source of cariostatic concentrations of fluoride in plaque fluid. The aim of this study was to quantify the amounts of plaque fluoride held in these reservoirs after a sodium fluoride rinse. 30 and 60 min after a 228 μg/g fluoride rinse, plaque samples were collected from 11 volunteers. Each sample was homogenized, split into 2 aliquots (aliquots 1 and 2...

  12. Antibacterial effect of taurolidine (2%) on established dental plaque biofilm.

    Science.gov (United States)

    Arweiler, Nicole Birgit; Auschill, Thorsten Mathias; Sculean, Anton

    2012-04-01

    Preliminary data have suggested that taurolidine may bear promising disinfectant properties for the therapy of bacterial infections. However, at present, the potential antibacterial effect of taurolidine on the supragingival plaque biofilm is unknown. To evaluate the antibacterial effect of taurolidine on the supragingival plaque biofilm using the vital fluorescence technique and to compare it with the effect of NaCl and chlorhexidine (CHX), 18 subjects had to refrain from all mechanical and chemical hygiene measures for 24 h. A voluminous supragingival plaque sample was taken from the buccal surfaces of the lower molars and wiped on an objective slide. The sample was then divided into three equal parts and mounted with one of the three test or control preparations (a) NaCl, (b) taurolidine 2% and (c) CHX 0.2%. After a reaction time of 2 min, the test solutions were sucked of. Subsequently, the plaque biofilm was stained with fluorescence dye and vitality of the plaque flora was evaluated under the fluorescence microscope (VF%). Plaque samples treated with NaCl showed a mean VF of 82.42 ± 6.04%. Taurolidine affected mean VF with 47.57 ± 16.60% significantly (p plaque biofilm which was, however, not as pronounced as that of CHX.

  13. Effects of gamma radiation from Cobalt 60 on eggs and adults of Sitotroga cerealella (Oliver, 1819) (Lepidoptera, Gelechiidae) in laboratory

    International Nuclear Information System (INIS)

    Rodrigues, Z.A.; Rego, A.M.; Oliveira, M.L. de; Ferreira, D.

    1983-01-01

    Lethal and sterilizing dosages from Cobalt-60 radiations were determined for Sitotroga cerealella (Oliver, 1819) eggs and adults. Eggs at the age of 0 to 24 hours were irradiated with dosages of 0,1,2; 4,6,8,10 and 12 krad; it was observed that 10 krad killed all embryos although this was not observed in 96 hours old eggs. A new group was irradiated with dosages of 0,60,80,100,120 and 140 krad, and complete lethal dosage was determined as 140 krad. Mating of irradiated with non irradiated insects resulted in 100% infertile eggs when either the males or females had received the dosage of 100 krad. Imediate lethality of S. cerealella adults was not observed with the dosages of 300 to 320 krad but all insects died after two days (L sup(D) 100/ 2 ). (Author) [pt

  14. Hematological changes in sheep inoculated with natural and Cobalt60-irradiated Crotalus durissus terrificus venom (Laurenti, 1768)

    International Nuclear Information System (INIS)

    Netto, D.P.; Alfieri, A.A.; Balarim, M.R.S.; Chiacchio, S.B.; Bicudo, P.L.; Nascimento, N.

    2004-01-01

    Natural (NV) and Cobalt 60 -irradiated (IrV) Crotalus durissus terrificus venom were used to evaluate serum production capacity of sheep and possible hematological and biochemical effects. Freeze-dried venom aliquots were diluted in acidified saline solution (NaCl 150 m M, p H 3.0) and irradiated by a Cobalt 60 source at a dose of 5.54 x 102 Gy/h and a concentration of 2.000 Gy. Twelve sheep were divided into two groups of six animals. One group received irradiated venom (IrV) and the other natural venom (NV). Three antigen doses (venom) were administered at monthly intervals. Blood samples were collected weekly for analysis of serum neutralization potency and capacity, complete blood count, total plasma protein, fibrinogen, albumin, and globulin. At the end of the experiment, the animals were challenged with a LD 50 for sheep and showed no signs of envenoming. The two groups did not present clinical alterations. Results of the total leukocyte count did not present interaction or time factor effect for both groups, but there was a different action between them, with the NV group presenting more cells than the IrV group. The leukocyte increase to 13,000/μl indicates that slight leucocytosis occurred in the week after the first inoculation in the NV group. There was no statistically significant difference between groups in the absolute count of segmented neutrophils, eosinophils, and lymphocytes but there were statistically significant oscillations in values at the different collecting times. The NV group presented an increase in the absolute neutrophil count after the first inoculation that persisted for 5 weeks. In the IrV group, the increase in neutrophils occurred only in the first week returning to normal in the following weeks. The alterations in the neutrophil count are indicative of systemic inflammatory response related to cytokine release; response was more marked in the N V group, showing its greater toxicity. (author)

  15. Estimation of cobalt release from feed water heater tubes of BWRs

    International Nuclear Information System (INIS)

    Uchida, S.; Kitamura, M.; Ozawa, Y.

    1983-01-01

    To evaluate the release source of cobalt from heater tubes of the feed water line, release rate measurements were carried out by detecting 60 Co released from irradiated stainless steel in contact with neutral water at an oxygen concentration of 20 ppb. The dependences of cobalt release rate on temperature, flow velocity and exposure time were studied after 670 hours of release experiments, and an empirical equation (which is presented) was obtained in the temperature range from 150 to 240 deg C. A decrease in the cobalt release rate above 250 deg C was considered due to the formation of a protective oxide layer. From these data, the amount of cobalt released from individual feed water heaters was evaluated. It was demonstrated that low cobalt containing stainless steel was economically applied only in the higher temperature region of the heater (20% of the total surface) to reduce cobalt feed rate into the reactor (to approx. 1/2). (author)

  16. Radiotherapy of bronchogenic carcinoma

    International Nuclear Information System (INIS)

    Heilmann, H.P.

    1982-01-01

    Radiotherapy of branchogenic carcinoma comprises; palliative treatment, postoperative or pre-operative radiotherapy, radiotherapy as part of a combination of chemotherapy and radiotherapy of small cell carcinoma and curative radiotherapy of non-operable non-small cell carcinoma. Atelectasis and obstruction are indications for palliative radiotherapy. Postoperative radiotherapy is given only in cases of incomplete resection or mediastinal metastases. In the treatment of small cell carcinoma by combined irradiation and chemotherapy the mediastinum and primary tumour are irradiated, generally after chemotherapy, and the C.N.S. receives prophylactic radiotherapy. Curative radiotherapy is indicated in cases of non-operable small cell carcinoma. Irradiation with doses of 60-70 Gy produced 5-years-survival rates of 10-14% in cases classified as T 1 -T 2 N 0 M 0 . (orig.) [de

  17. Late course accelerated fractionation in radiotherapy of esophageal carcinoma

    International Nuclear Information System (INIS)

    Shi, X.-H.; Yao, W.; Liu, T.

    1999-01-01

    Purpose: To evaluate the efficacy of adding accelerated fractionation after completing two thirds of routine fractionated radiotherapy in esophageal carcinoma.Methods and materials: From April 1988 to April 1990, 85 patients with histologically confirmed carcinoma of the esophagus were randomized into two groups. (1) The conventional fractionation (CF) group, received 1.8 Gy per day five times a week to a total dose of 68.4 Gy in 7-8 weeks, and (2) the late course accelerated hyperfractionated (LCAF) group which received the same schedule as the CF group during the first two thirds of the course of radiotherapy to a dose of 41.4 Gy/23 fx/4 to 5 weeks. This was then followed by accelerated hyperfractionation using reduced fields. In the LCAF portion of the radiotherapeutic course, the irradiation schedule was changed to 1.5 Gy twice a day, with an interval of 4 h between fractions, to a dose of 27 Gy/18 fx. Thus the total dose was also 68.4 Gy, the same as the CF group, but the course of radiotherapy was shorter, being only 6.4 weeks. The same Cobalt 60 teletherapy unit was used to treat all the cases.Results: The 5 year actuarial survival and disease-free survival rates in the LCAF group were 34% and 42%, as compared to 15% and 15% respectively in the CF group, all statistically significant. Better local control was seen in the LCAF group than in the CF group, the 5 year control rates being 55% versus 21% (P=0.003). The acute reactions were increased but acceptable in the LCAF patients, the radiation treatments could be completed without any breaks. The late reactions as observed after 5 years were not increased in comparison with the CF patients.Conclusions: The results from this study show that the late course accelerated hyperfractionated radiotherapy regime can improve results in esophageal carcinoma, with acceptable acute reactions as compared to conventional radiotherapy. (Copyright (c) 1999 Elsevier Science B.V., Amsterdam. All rights reserved.)

  18. First experiences with model based iterative reconstructions influence on quantitative plaque volume and intensity measurements in coronary computed tomography angiography

    International Nuclear Information System (INIS)

    Precht, H.; Kitslaar, P.H.; Broersen, A.; Gerke, O.; Dijkstra, J.; Thygesen, J.; Egstrup, K.; Lambrechtsen, J.

    2017-01-01

    Purpose: Investigate the influence of adaptive statistical iterative reconstruction (ASIR) and the model-based IR (Veo) reconstruction algorithm in coronary computed tomography angiography (CCTA) images on quantitative measurements in coronary arteries for plaque volumes and intensities. Methods: Three patients had three independent dose reduced CCTA performed and reconstructed with 30% ASIR (CTDI vol at 6.7 mGy), 60% ASIR (CTDI vol 4.3 mGy) and Veo (CTDI vol at 1.9 mGy). Coronary plaque analysis was performed for each measured CCTA volumes, plaque burden and intensities. Results: Plaque volume and plaque burden show a decreasing tendency from ASIR to Veo as median volume for ASIR is 314 mm 3 and 337 mm 3 –252 mm 3 for Veo and plaque burden is 42% and 44% for ASIR to 39% for Veo. The lumen and vessel volume decrease slightly from 30% ASIR to 60% ASIR with 498 mm 3 –391 mm 3 for lumen volume and vessel volume from 939 mm 3 to 830 mm 3 . The intensities did not change overall between the different reconstructions for either lumen or plaque. Conclusion: We found a tendency of decreasing plaque volumes and plaque burden but no change in intensities with the use of low dose Veo CCTA (1.9 mGy) compared to dose reduced ASIR CCTA (6.7 mGy & 4.3 mGy), although more studies are warranted. - Highlights: • Veo decrease plaque volumes and plaque burden using low-dose CCTA. • Moving from ASIR 30%, ASIR 60% to Veo did not appear to influence the plaque intensities. • Studies including larger sample size are needed to investigate the effect on plaque.

  19. SU-C-BRC-01: A Monte Carlo Study of Out-Of-Field Doses From Cobalt-60 Teletherapy Units Intended for Historical Correlations of Dose to Normal Tissue

    Energy Technology Data Exchange (ETDEWEB)

    Petroccia, H [University of Florida, Gainesville, FL (United States); Olguin, E [Gainesville, FL (United States); Culberson, W [University of Wisconsin Madison, Madison, WI (United States); Bednarz, B [University of Wisconsin, Madison, WI (United States); Mendenhall, N [UF Health Proton Therapy Institute, Jacksonville, FL (United States); Bolch, W [University Florida, Gainesville, FL (United States)

    2016-06-15

    Purpose: Innovations in radiotherapy treatments, such as dynamic IMRT, VMAT, and SBRT/SRS, result in larger proportions of low-dose regions where normal tissues are exposed to low doses levels. Low doses of radiation have been linked to secondary cancers and cardiac toxicities. The AAPM TG Committee No.158 entitled, ‘Measurements and Calculations of Doses outside the Treatment Volume from External-Beam Radiation Therapy’, has been formed to review the dosimetry of non-target and out-of-field exposures using experimental and computational approaches. Studies on historical patients can provide comprehensive information about secondary effects from out-of-field doses when combined with long-term patient follow-up, thus providing significant insight into projecting future outcomes of patients undergoing modern-day treatments. Methods: We present a Monte Carlo model of a Theratron-1000 cobalt-60 teletherapy unit, which historically treated patients at the University of Florida, as a means of determining doses located outside the primary beam. Experimental data for a similar Theratron-1000 was obtained at the University of Wisconsin’s ADCL to benchmark the model for out-of-field dosimetry. An Exradin A12 ion chamber and TLD100 chips were used to measure doses in an extended water phantom to 60 cm outside the primary field at 5 and 10 cm depths. Results: Comparison between simulated and experimental measurements of PDDs and lateral profiles show good agreement for in-field and out-of-field doses. At 10 cm away from the edge of a 6×6, 10×10, and 20×20 cm2 field, relative out-of-field doses were measured in the range of 0.5% to 3% of the dose measured at 5 cm depth along the CAX. Conclusion: Out-of-field doses can be as high as 90 to 180 cGy assuming historical prescription doses of 30 to 60 Gy and should be considered when correlating late effects with normal tissue dose.

  20. Developing a mailed phantom to implement a local QA program in Egypt radiotherapy centers

    Science.gov (United States)

    Soliman, H. A.; Aletreby, M.

    2016-07-01

    In this work, a simple method that differs from the IAEA/WHO Thermoluminescent dosimeters (TLD) postal quality assurance (QA) program is developed. A small perspex; polymethyl methacrylate (PMMA), phantom measured 50 mm × 50 mm × 50 mm is constructed to be used for absorbed dose verification of high-energy photon beams in some major radiotherapy centers in Egypt. The phantom weighted only 140.7 g with two buildup covers weighted 14.8 and 43.19 g for the Cobalt-60 and the 6-MV X-ray beams, respectively. This phantom is aimed for use in the future's external audit/QA services in Egypt for the first time. TLD-700 chips are used for testing and investigating a convenient and national dosimetry QA program. Although the used methodology is comparable to previously introduced but new system; it has smaller size, less weight, and different more available material. Comparison with the previous similar designs is introduced. Theoretical calculations were done by the commercial Eclipse treatment planning system, implementing the pencil beam convolution algorithm to verify the accuracy of the experimental calculation of the dose conversion factor of water to the perspex phantom. The new constructed small phantom and methodology was applied in 10 participating radiotherapy centers. The absorbed dose was verified under the reference conditions for both 60Co and 6-MV high-energy photon beams. The checked beams were within the 5% limit except for four photon beams. There was an agreement of 0.2% between our experimental data and those previously published confirming the validity of the applied method in verifying radiotherapy absorbed dose.

  1. Plaque echodensity and textural features are associated with histologic carotid plaque instability.

    Science.gov (United States)

    Doonan, Robert J; Gorgui, Jessica; Veinot, Jean P; Lai, Chi; Kyriacou, Efthyvoulos; Corriveau, Marc M; Steinmetz, Oren K; Daskalopoulou, Stella S

    2016-09-01

    Carotid plaque echodensity and texture features predict cerebrovascular symptomatology. Our purpose was to determine the association of echodensity and textural features obtained from a digital image analysis (DIA) program with histologic features of plaque instability as well as to identify the specific morphologic characteristics of unstable plaques. Patients scheduled to undergo carotid endarterectomy were recruited and underwent carotid ultrasound imaging. DIA was performed to extract echodensity and textural features using Plaque Texture Analysis software (LifeQ Medical Ltd, Nicosia, Cyprus). Carotid plaque surgical specimens were obtained and analyzed histologically. Principal component analysis (PCA) was performed to reduce imaging variables. Logistic regression models were used to determine if PCA variables and individual imaging variables predicted histologic features of plaque instability. Image analysis data from 160 patients were analyzed. Individual imaging features of plaque echolucency and homogeneity were associated with a more unstable plaque phenotype on histology. These results were independent of age, sex, and degree of carotid stenosis. PCA reduced 39 individual imaging variables to five PCA variables. PCA1 and PCA2 were significantly associated with overall plaque instability on histology (both P = .02), whereas PCA3 did not achieve statistical significance (P = .07). DIA features of carotid plaques are associated with histologic plaque instability as assessed by multiple histologic features. Importantly, unstable plaques on histology appear more echolucent and homogeneous on ultrasound imaging. These results are independent of stenosis, suggesting that image analysis may have a role in refining the selection of patients who undergo carotid endarterectomy. Copyright © 2016 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.

  2. Reconstruction of exposures to the public from a cobalt-60 irradiator facility

    International Nuclear Information System (INIS)

    Chapman, T.E.; Scherpelz, R.I.

    1992-01-01

    A study was performed for the US Department of Energy (DOE) to assess the radiation exposure received by the public from the operation of a cobalt-60 irradiator facility. Located south of Davis, California, at the former Laboratory for Energy-Related Health Research, the facility was an indoor-outdoor gamma irradiator operated for the DOE by the University of California, Davis. From 1970 to 1985, outdoor radiation exposure experiments conducted at the facility resulted in environmental radiation doses of 80 to 120 mSv per year along the facility's perimeter fence. Comprehensive environmental monitoring was not performed in the adjacent, uncontrolled areas and personnel who occupied these areas were not routinely monitored for radiation exposure. Because of incomplete environmental monitoring data, computer modeling was required to reconstruct the environmental dose rates present when the facility was in operation. Personnel occupancy times for the adjacent areas were determined from population statistics, historical records, and personal interviews. The potential dose equivalents calculated for the individuals who lived or worked in neighboring areas ranged from 0.02 to 3.6 mSv per year. These exposures, some of which exceed the current DOE standard of 1 mSv/y, were less than the DOE regulatory limit of 5 mSv/y for exposure to the public that was in effect when the facility was in operation

  3. Separation of cobalt from synthetic intermediate and decontamination radioactive wastes using polyurethane foam

    International Nuclear Information System (INIS)

    Rao, S.V.S.; Lal, K.B.; Narasimhan, S.V.; Ahmed, J.

    1997-01-01

    Studies have been carried out on the removal of radioactive cobalt ( 60 Co) from synthetic intermediate level waste (ILW) and decontamination waste using neat polyurethane (PU) foam as well as n-tributyl phosphate-polyurethane (TBP-PU) foam. The radioactive cobalt has been extracted on the PU foam as cobalt thiocyanate from the ILW. Maximum removal of cobalt has been observed when the concentration of thiocyanate in the solution is about 0.4 M. Cobalt can be separated from decontamination waste containing ethylenediaminetetraacetic acid (EDTA) and iron(II). The extent of extraction of cobalt is slow and the separation of iron and cobalt is better with the neat PU foam compared to the TBP-PU foam. The presence of iron in the decontamination waste facilitates the extraction of cobalt thiocyanate on the PU foam. Column studies have been carried out in order to extend these studies to the plant scale. The capacities of the PU foams for cobalt have been determined. The effect of density and the surface area of PU foam have been investigated. Fourier Transform Infrared (FT-IR) spectral studies have been conducted to find out the interaction between PU foam and cobalt thiocyanate species

  4. Analysis of quality control protocol implementation of equipment in radiotherapy services

    International Nuclear Information System (INIS)

    Calcina, Carmen S. Guzman; Lima, Luciana P. de; Rubo, Rodrigo A.; Ferraz, Eduardo; Almeida, Adelaide de

    2000-01-01

    Considering the importance of the Quality Assurance in the radiotherapy services, there was an interest to make tests' evaluation for a Quality Control for the cobalt equipment, linear accelerator and simulator as a classification and comparison. The work proposed is a suggestion that can serve as tool for medical physicists that are starting to work in the radiotherapy area and for the most experts. The discussions were made by the gathering of local tests and official protocols, resulting in a minimum protocol as a suggestion for a routine work, emphasizing the periodicity and level of tolerance of each one of the tests. (author)

  5. Effects of gamma radiation of Cobalt-60 on different phases of the evolutive cycle of pinworm - Tuta absoluta (Meyrich, 1917) (Lepidoptera,Gelechiidae)

    International Nuclear Information System (INIS)

    Groppo, Gerson Antonio

    1996-10-01

    The effects of different gamma radiation (Cobalt-60) doses on different phases of the evolutive cycle of Tuta absoluta (Meyrich, 1917) (Lepidoptera, Gelechiidae) have been studied under laboratory conditions in the laboratory of Entomology of Center for Nuclear Energy in Agriculture (CENA), University of Sao Paulo, Piracicaba, Sao Paulo State, Brazil. For all the treatments with gamma radiation a Cobalt-60 source type Gamma beam-650 was used. The doses utilized ranged from of 0,0 (Control) to 3250 Gy with a dose rate of 1110 Gy/h. The experiment was conducted under controlled conditions at 25± 2 deg C, 70 ± 5% of relative humidity and photo period of (12:12). It was verified that the lethal doses were: for eggs - 70 Gy; for larvae - 200 Gy e for pupae - 300 Gy. The sterilizing dose for adults from irradiated larvae was 45 Gy. The sterilizing dose for the crossing of irradiated female with normal males (FI X MN) was 100 Gy and for normal female with irradiated male (FN x MI) was 150 Gy, in the both crosses, doses refer to irradiation of pupae. The sterilizing dose for adults, of both sexes, irradiated and crossed with normal adults, (FI x MN) and (FN x MI, were 150 and 200 Gy, respectively. The average longevity of adults, of both sexes, irradiated and crossed with normal adults was 8,3 days. The immediate lethal dose for adults was 3250 Gy. (author)

  6. Preliminary studies of cobalt complexation in groundwater

    International Nuclear Information System (INIS)

    Warwick, P.; Shaw, P.; Williams, G.M.; Hooker, P.J.

    1988-01-01

    A relatively non-invasive method has been used to separate complexed from free cobalt-60 in groundwater, using the weak cationic adsorption properties of Sephadex gels, and a mobile phase of natural groundwater. Results show the kinetics of Co complex formation in groundwater to be slow, and that the equilibrium position is affected by temperature, cobalt concentration and the ionic/organic strength of the groundwater. The addition of DAEA cellulose to the groundwater to remove humic material, also removed the majority of organic species which absorb UV at 254 nm, but 45% of the original total organic carbon remained, and the amount of complexed cobalt left in solution was only reduced to 76% of its former concentration. This suggests that the completed Co species separated by the method described in this paper are a mixture of inorganic and organic compounds, and studies are therefore continuing to establish their exact nature. (author)

  7. Preliminary studies of cobalt complexation in groundwater

    International Nuclear Information System (INIS)

    Warwick, P.; Shaw, P.; Williams, G.M.; Hooker, P.J.

    1988-01-01

    A relatively non-invasive method has been used to separate complexed from free cobalt-60 in groundwater, using the weak cationic adsorption properties of Sephadex gels, and a mobile phase of natural groundwater. Results show the kinetics of Co complex formation in groundwater to be slow, and that the equilibrium position is affected by temperature, cobalt concentration and the ionic/organic strength of the groundwater. The addition of DEAE cellulose to the groundwater to remove humic material, also removed the majority of organic species with absorb UV at 254 nm, but 45% of the original total organic carbon remained, and the amount of complexed cobalt left in solution was only reduced to 76% of its former concentration. This suggests that the complexed Co species separated by the method described in this paper are a mixture of inorganic and organic compounds, and studies are therefore continuing to establish their exact nature. (orig.)

  8. The impact of postoperative supraclavicular radiotherapy on tracheoesophageal groove lymph node metastasis in esophageal carcinoma

    International Nuclear Information System (INIS)

    Qian Pudong; Lu Jinchen; Mei Zeru; Zhu Jun

    2005-01-01

    Objective: To evaluate the prognostic factors of tracheoesophageal groove lymph node (TEGLN) metastasis in postoperative esophageal carcinoma. Methods: From January 1996 to December 1997, 101 postoperative cervical and thoracic esophageal carcinoma patients proved absence from tracheoesophageal groove lymph node (TEGIAN) metastasis before and after operation by physical examination and computer tomography examination were entered into this study. The patients were divided into three groups according to the treatment of supraclavicular region: no prophylactic radiotherapy (group A-, 30 patients); prophylactic radiotherapy with local dose < 45 Gy (Group B-, 71 patients); and prophylactic radiotherapy with local dose ≥45 Gy (Group C-, 19 patients). Radiotherapy was delivered by cobalt- 60 or 6 MV X-ray with the prescribed dose normalized to the point of tracheoesophageal groove, i. e, 5 cm in depth. The tracheoesophageal groove lymph node metastasis after treatment was observed. Results: The incidence of tracheoesophageal groove lymph node metastasis was 20% (6/30), 9.6% (5/71) and 0% (0/19) in groups A, B and C. Univariate analysis showed that there was significant difference of TEGLN metastasis between groups A and C only (P=0.039), but higher dose to supraclavicular region tended to lower the incidence of TEGLN metastasis. Multivariate analysis showed that only prophylactic radiotherapy to the supraclavicular region was independent prognostic factor for TEGLN metastasis (P=0.037). Gender, primary tumor site and pathological stage had no significant impact on TEGLN metastasis. Conclusions: Postoperative prophylactic supraclavicular region irradiation can lower the incidence of tracheoesophageal groove lymph node metastasis in esophageal carcinoma. Radiotherapy dose should not be less than 45 Gy and should be routinely normalized to a point 5 cm deep in the tracheoesophageal groove. (authors)

  9. Flux perturbation factor in cobalt samples for the reactor production of Co-60

    International Nuclear Information System (INIS)

    Curzio, O.A.

    1976-07-01

    Total flux perturbation factor (F) is experimentally determined for hollow cylinder cobalt samples irradiated in the RA-3 reactor. F factor is studied for different thicknesses of the material and the values are compared with those theoretically estimated by Dwork for a similar. (author) [es

  10. Mobility and retention of Co-60 in soils in coastal areas

    International Nuclear Information System (INIS)

    Mahara, Y.; Kudo, A.

    1980-01-01

    The purpose of this study was to determine the mobility of radioactive cobalt ( 60 Co), a typical operating waste, in soils in coastal areas (where all Japanese commercial reactors are located). The results of this investigation may assist in evaluating a degree of safety for the future disposal of radioactive wastes underground. Freshwater and seawater were examined under both aerobic and anaerobic conditions by simulating the environmental conditions of the soils in coastal areas. More than 80% of 60 Co moves freely within soils covered by seawater under anaerobic conditions. Furthermore, the cobalt in the water phase can pass through a dialysis membrane with a pore size of 24 A. This indicates that the cobalt is either in ionic form or associated with materials of low molecular weight. On the other hand, more than 95% of 60 Co was retained by soils covered by freshwater under aerobic conditions. This cobalt, once fixed on soils, was not easily desorbed by seawater under anaerobic conditions. The results suggest that the mobility of cobalt disposed of underground is greatly enced by the initial environmental conditions in the soils in coastal areas. (H.K.)

  11. Hematological changes in sheep inoculated with natural and Cobalt{sub 60}-irradiated Crotalus durissus terrificus venom (Laurenti, 1768)

    Energy Technology Data Exchange (ETDEWEB)

    Netto, D.P.; Alfieri, A.A.; Balarim, M.R.S. [Universidade Estadual de Londrina, PR (Brazil). Faculdade de Medicina Veterinaria e Zootecnia. Dept. de Medicina Veterinaria Preventiva]. E-mail: rnetto@uel.br; Chiacchio, S.B.; Bicudo, P.L. [UNESP, Botucatu, SP (Brazil). Faculdade de Medicina Veterinaria e Zootecnia; Nascimento, N. [Instituto de Pesquisas Energeticas e Nucleares (IPEN), Sao Paulo, SP (Brazil). Supervisao de Radiobiologia

    2004-07-01

    Natural (NV) and Cobalt{sub 60}-irradiated (IrV) Crotalus durissus terrificus venom were used to evaluate serum production capacity of sheep and possible hematological and biochemical effects. Freeze-dried venom aliquots were diluted in acidified saline solution (NaCl 150 m M, p H 3.0) and irradiated by a Cobalt 60 source at a dose of 5.54 x 102 Gy/h and a concentration of 2.000 Gy. Twelve sheep were divided into two groups of six animals. One group received irradiated venom (IrV) and the other natural venom (NV). Three antigen doses (venom) were administered at monthly intervals. Blood samples were collected weekly for analysis of serum neutralization potency and capacity, complete blood count, total plasma protein, fibrinogen, albumin, and globulin. At the end of the experiment, the animals were challenged with a LD{sub 50} for sheep and showed no signs of envenoming. The two groups did not present clinical alterations. Results of the total leukocyte count did not present interaction or time factor effect for both groups, but there was a different action between them, with the NV group presenting more cells than the IrV group. The leukocyte increase to 13,000/{mu}l indicates that slight leucocytosis occurred in the week after the first inoculation in the NV group. There was no statistically significant difference between groups in the absolute count of segmented neutrophils, eosinophils, and lymphocytes but there were statistically significant oscillations in values at the different collecting times. The NV group presented an increase in the absolute neutrophil count after the first inoculation that persisted for 5 weeks. In the IrV group, the increase in neutrophils occurred only in the first week returning to normal in the following weeks. The alterations in the neutrophil count are indicative of systemic inflammatory response related to cytokine release; response was more marked in the N V group, showing its greater toxicity. (author)

  12. Therapeutic Results of Radiotherapy in Rectal Carcinoma -Comparison of Sandwich Technique Radiotherapy with Postoperative Radiotherapy

    International Nuclear Information System (INIS)

    Huh, Gil Cha; Suh, Hyun Suk; Lee, Hyuk Sang; Kim, Re Hwe; Kim, Chul Soo; Kim, Hong Yong; Kim, Sung Rok

    1996-01-01

    Purpose : To evaluate the potential advantage for 'sandwich' technique radiotherapy compared to postoperative radiotherapy in respectable rectal cancer. Between January 1989 and May 1994, 60 patients with respectable rectal cancer were treated at Inje University Seoul and Sanggye Paik Hospital.Fifty one patients were available for analysis : 20 patients were treated with sandwich technique radiotherapy and 31 patients were treated with postoperative radiotherapy. In sandwich technique radiotherapy(RT), patients were treated with preoperative RT 1500 cGy/5fx followed by immediate curative resection. Patients staged as Astler-Coller B2, C were considered for postoperative RT with 2500-4500 cGy. In postoperative RT, total radiation dose of 4500-6120 cGy, 180 cGy daily at 4-6 weeks was delivered. Patients were followed for median period of 25 months. Results : The overall 5-year survival rates for sandwich technique RT group and postoperative RT group were 60% and 71%, respectively(p>0.05). The 5-year disease free survival rates for each group were 63%. There was no difference in local failure rate between two groups(11% versus 7%). Incidence of distant metastasis was 11%(2/20) in the sandwich technique RT group and 20%(6/31) in the postoperative RT group(p>0.05). The frequencies of acute and chronic complications were comparable in both groups. Conclusion : The sandwich technique radiotherapy group shows local recurrence and survival similar to those of postoperative RT alone group but reduced distant metastasis compared to postoperative RT group. But long term follow-up and large number of patients is needed to make an any firm conclusion regarding the value of this sandwich technique RT

  13. Effect of coconut oil in plaque related gingivitis - A preliminary report.

    Science.gov (United States)

    Peedikayil, Faizal C; Sreenivasan, Prathima; Narayanan, Arun

    2015-01-01

    Oil pulling or oil swishing therapy is a traditional procedure in which the practitioners rinse or swish oil in their mouth. It is supposed to cure oral and systemic diseases but the evidence is minimal. Oil pulling with sesame oil and sunflower oil was found to reduce plaque related gingivitis. Coconut oil is an easily available edible oil. It is unique because it contains predominantly medium chain fatty acids of which 45-50 percent is lauric acid. Lauric acid has proven anti inflammatory and antimicrobial effects. No studies have been done on the benefits of oil pulling using coconut oil to date. So a pilot study was planned to assess the effect of coconut oil pulling on plaque induced gingivitis. The aim of the study was to evaluate the effect of coconut oil pulling/oil swishing on plaque formation and plaque induced gingivitis. A prospective interventional study was carried out. 60 age matched adolescent boys and girls in the age-group of 16-18 years with plaque induced gingivitis were included in the study and oil pulling was included in their oral hygiene routine. The study period was 30 days. Plaque and gingival indices of the subjects were assessed at baseline days 1,7,15 and 30. The data was analyzed using paired t test. A statistically significant decrease in the plaque and gingival indices was noticed from day 7 and the scores continued to decrease during the period of study. Oil pulling using coconut oil could be an effective adjuvant procedure in decreasing plaque formation and plaque induced gingivitis.

  14. Effect of (/sup 60/cobalt) gamma rays on growth and root rot diseases in mungbean (vigna radiata L.)

    International Nuclear Information System (INIS)

    Ikram, N.; Dawar, S.; Zaki, M.J.; Abass, Z.

    2010-01-01

    Present investigation showed that gamma rays influences suppressive effect on root rot fungi such as Macrophomina phaseolina (Tassi) Goid, Rhizoctonia solani Kuhn and Fusarium spp., and inducive effect on growth parameters of mung bean (Vigna radiata L.). Seeds of mung bean were treated with gamma rays (/sup 60/Cobalt) at time periods of 0 and 4 minutes and stored for 90 days at room temperature to determine its effect on growth parameters and infection of root infecting fungi. All treatments of gamma rays enhanced the growth parameters as compared to untreated plants. Infection of M. phaseolina, R. solani and Fusarium spp., were significantly decreased on mung bean seeds treated with gamma rays. Gamma rays significantly increased the growth parameters and controlled the root rot fungi up to 90 days of storage of seeds. (author)

  15. Natural history of dental plaque accumulation in mechanically ventilated adults: a descriptive correlational study.

    Science.gov (United States)

    Jones, Deborah J; Munro, Cindy L; Grap, Mary Jo

    2011-12-01

    The purpose of this study was to describe the pattern of dental plaque accumulation in mechanically ventilated adults. Accumulation of dental plaque and bacterial colonisation of the oropharynx is associated with a number of systemic diseases including ventilator associated pneumonia. Data were collected from mechanically ventilated critically ill adults (n=137), enrolled within 24 hours of intubation. Dental plaque, counts of decayed, missing and filled teeth and systemic antibiotic use was assessed on study days 1, 3, 5 and 7. Dental plaque averages per study day, tooth type and tooth location were analysed. Medical respiratory, surgical trauma and neuroscience ICU's of a large tertiary care centre in the southeast United States. Plaque: all surfaces >60% plaque coverage from day 1 to day 7; molars and premolars contained greatest plaque average >70%. Systemic antibiotic use on day 1 had no significant effect on plaque accumulation on day 3 (p=0.73). Patients arrive in critical care units with preexisting oral hygiene issues. Dental plaque tends to accumulate in the posterior teeth (molars and premolars) that may be hard for nurses to visualise and reach; this problem may be exacerbated by endotracheal tubes and other equipment. Knowing accumulation trends of plaque will guide the development of effective oral care protocols. Published by Elsevier Ltd.

  16. Recovery of Cobalt as Cobalt Oxalate from Cobalt Tailings Using Moderately Thermophilic Bioleaching Technology and Selective Sequential Extraction

    Directory of Open Access Journals (Sweden)

    Guobao Chen

    2016-07-01

    Full Text Available Cobalt is a very important metal which is widely applied in various critical areas, however, it is difficult to recover cobalt from minerals since there is a lack of independent cobalt deposits in nature. This work is to provide a complete process to recover cobalt from cobalt tailings using the moderately thermophilic bioleaching technology and selective sequential extraction. It is found that 96.51% Co and 26.32% Cu were extracted after bioleaching for four days at 10% pulp density. The mean compositions of the leach solutions contain 0.98 g·L−1 of Co, 6.52 g·L−1 of Cu, and 24.57 g·L−1 of Fe (III. The copper ion was then recovered by a solvent extraction process and the ferric ions were selectively removed by applying a goethite deironization process. The technological conditions of the above purification procedures were deliberately discussed. Over 98.6% of copper and 99.9% of ferric ions were eliminated from the leaching liquor. Cobalt was finally produced as cobalt oxalate and its overall recovery during the whole process was greater than 95%. The present bioleaching process of cobalt is worth using for reference to deal with low-grade cobalt ores.

  17. Polytypic transformations during the thermal decomposition of cobalt hydroxide and cobalt hydroxynitrate

    International Nuclear Information System (INIS)

    Ramesh, Thimmasandra Narayan

    2010-01-01

    The isothermal decomposition of cobalt hydroxide and cobalt hydroxynitrate at different intervals of temperature leads to the formation of Co 3 O 4 . The phase evolution during the decomposition process was monitored using powder X-ray diffraction. The transformation of cobalt hydroxide to cobalt oxide occurs via three phase mixture while cobalt hydroxynitrate to cobalt oxide occurs through a two phase mixture. The nature of the sample and its preparation method controls the decomposition mechanism. The comparison of topotactical relationship between the precursors to the decomposed product has been reported in relation to polytypism. - Graphical abstract: Isothermal thermal decomposition studies of cobalt hydroxide and cobalt hydroxynitrate at different intervals of temperature show the metastable phase formed prior to Co 3 O 4 phase.

  18. Microbiological Load Of Ethylene Oxide Sterilized Medical Devices And Its Elimination By Cobalt 60 Source

    International Nuclear Information System (INIS)

    Bashir, R.; Afroze, B.; Zulfiqar, H. F.; Saleem, R.; Saleem, F.; Aslam, F.; Naz, S.

    2016-01-01

    Objective: To determine the residing microbial flora of ethylene oxide (EtO) sterilized medical devices and optimization of safe dose of gamma radiation (Cobalt 60 source) for the complete elimination of microbial load. Study Design: Experimental study. Place and Duration of Study: Department of Biotechnology, Lahore College for Women University, Lahore, Pakistan from September 2014 to June 2015. Methodology: Thirty-six samples of EtO sterilized medical devices of same batch of three different companies were collected for this study. Isolation and enumeration of microbes were done by using different selective and differential media. Gram staining and biochemically characterization by API 20 (Bio Merieux, France) kit was done for identification of the microorganisms. The medical devices having high microbial load were sent to Pakistan Radiation Services (PARAS) for gamma irradiations at 3 different selected doses (20 KGy, 25 KGy, and 30 KGy). Result: Different types of Gram positive bacteria (Staphylococcus epidermidis, Staphylococcus aureus and Bacillus subtilis) were isolated from the EtO sterilized samples. Gram negative bacteria and fungi were not detected on these medical devices. Gamma irradiations Result showed that 30 KGy was optimized dose for complete elimination of microbial flora on endotracheal, Nelaton, and tracheostomy tubes. Conclusion: Gamma radiations (Co 60 source) effectively decontaminate the microbial flora on the equipment previously sterilized by the ethylene oxide gas; and 30 KGy is the optimized dose for all these medical devices. (author)

  19. Matrix vesicles in the fibrous cap of atherosclerotic plaque: possible contribution to plaque rupture.

    Science.gov (United States)

    Bobryshev, Y V; Killingsworth, M C; Lord, R S A; Grabs, A J

    2008-10-01

    Plaque rupture is the most common type of plaque complication and leads to acute ischaemic events such as myocardial infarction and stroke. Calcification has been suggested as a possible indicator of plaque instability. Although the role of matrix vesicles in the initial stages of arterial calcification has been recognized, no studies have yet been carried out to examine a possible role of matrix vesicles in plaque destabilization. Tissue specimens selected for the present study represented carotid specimens obtained from patients undergoing carotid endarterectomy. Serial frozen cross-sections of the tissue specimens were cut and mounted on glass slides. The thickness of the fibrous cap (FCT) in each advanced atherosclerotic lesion, containing a well developed lipid/necrotic core, was measured at its narrowest sites in sets of serial sections. According to established criteria, atherosclerotic plaque specimens were histologically subdivided into two groups: vulnerable plaques with thin fibrous caps (FCT <100 microm) and presumably stable plaques, in which fibrous caps were thicker than 100 microm. Twenty-four carotid plaques (12 vulnerable and 12 presumably stable plaques) were collected for the present analysis of matrix vesicles in fibrous caps. In order to provide a sufficient number of representative areas from each plaque, laser capture microdissection (LCM) was carried out. The quantification of matrix vesicles in ultrathin sections of vulnerable and stable plaques revealed that the numbers of matrix vesicles were significantly higher in fibrous caps of vulnerable plaques than those in stable plaques (8.908+0.544 versus 6.208+0.467 matrix vesicles per 1.92 microm2 standard area; P= 0.0002). Electron microscopy combined with X-ray elemental microanalysis showed that some matrix vesicles in atherosclerotic plaques were undergoing calcification and were characterized by a high content of calcium and phosphorus. The percentage of calcified matrix vesicles

  20. Preoperative cobalt60 irradiation delays the healing of rectal anastomoses in rats

    International Nuclear Information System (INIS)

    Fang, C.B.; Klug, W.A.; Capelhuchnik, P.

    2005-01-01

    The healing of colorectal anastomoses after irradiation therapy continues to be a major concern. The authors evaluated the healing of rectal anastomoses in a rat model after a preoperative 500-c Gy dose of cobalt 60 irradiation. Thirty-six male Wistar rats were divided into two equal groups: control (group A), and irradiation group (group B). Group B received a single 500-c Gy dose of irradiation, and a rectal resection and end-to-end anastomosis was performed in both groups on the seventh day after irradiation. Parameters of the healing process included bursting pressure and collagen content on the fifth, seventh, and fourteenth days after surgery. In the irradiation group, the mean bursting pressure on the fifth, seventh, and fourteenth days was 116, 218, and 273 mmHg, respectively. The collagen content assessed by histomorphometry was 9.0, 20.8, and 32%, respectively. In contrast, the control group had a mean bursting pressure of 175, 225 and 263 mmHg, and a collagen content of 17.8, 28.1, and 32.1%, respectively. The adverse effect of irradiation on healing was detectable only on the fifth postoperative day, as demonstrated by lower bursting pressure (P < 0.013) and collagen content (P < 0.008). However, there was no failure of anastomotic healing such as leakage or dehiscence due to irradiation. We conclude that a single preoperative 500-c Gy dose of irradiation delays the healing of rectal anastomosis in rats. (author)

  1. Stevens-Johnson syndrome after radiotherapy

    International Nuclear Information System (INIS)

    Howell, W.R.; Knight, A.L.; Scruggs, H.J.

    1990-01-01

    We have reported a case of classic Stevens-Johnson syndrome in association with treatment using a cobalt radiation therapy unit. Previous reports of such an association have been extremely rare. At the time of the reaction, the patient's only medications were methyldopa and trichlormethiazide. Other drugs in the thiazide class have been associated with such a reaction. We feel this is an unlikely association in our patient, however, because she had been on trichlormethiazide for a number of years. This report suggests the role of radiotherapy as a rare cause of Stevens-Johnson syndrome. 14 references

  2. A dose homogeneity and conformity evaluation between ViewRay and pinnacle-based linear accelerator IMRT treatment plans

    OpenAIRE

    Daniel L Saenz; Bhudatt R Paliwal; John E Bayouth

    2014-01-01

    ViewRay, a novel technology providing soft-tissue imaging during radiotherapy is investigated for treatment planning capabilities assessing treatment plan dose homogeneity and conformity compared with linear accelerator plans. ViewRay offers both adaptive radiotherapy and image guidance. The combination of cobalt-60 (Co-60) with 0.35 Tesla magnetic resonance imaging (MRI) allows for magnetic resonance (MR)-guided intensity-modulated radiation therapy (IMRT) delivery with multiple beams. This ...

  3. Implementation of a risk assessment tool based on a probabilistic safety assessment developed for radiotherapy practices

    International Nuclear Information System (INIS)

    Paz, A.; Godinez, V.; Lopez, R.

    2010-10-01

    The present work describes the implementation process and main results of the risk assessment to the radiotherapy practices with Linear Accelerators (Linac), with cobalt 60, and with brachytherapy. These evaluations were made throughout the risk assessment tool for radiotherapy practices SEVRRA (risk evaluation system for radiotherapy), developed at the Mexican National Commission in Nuclear Safety and Safeguards derived from the outcome obtained with the Probabilistic Safety Analysis developed at the Ibero-American Regulators Forum for these radiotherapy facilities. The methodology used is supported by risk matrices method, a mathematical tool that estimates the risk to the patient, radiation workers and public from mechanical failures, mis calibration of the devices, human mistakes, and so. The initiating events are defined as those undesirable events that, together with other failures, can produce a delivery of an over-dose or an under-dose of the medical prescribed dose, to the planned target volume, or a significant dose to non prescribed human organs. Initiating events frequency and reducer of its frequency (actions intended to avoid the accident) are estimated as well as robustness of barriers to those actions, such as mechanical switches, which detect and prevent the accident from occurring. The spectrum of the consequences is parameterized, and the actions performed to reduce the consequences are identified. Based on this analysis, a software tool was developed in order to simplify the evaluations to radiotherapy installations and it has been applied as a first step forward to some Mexican installations, as part of a national implementation process, the final goal is evaluation of all Mexican facilities in the near future. The main target and benefits of the SEVRRA implementation are presented in this paper. (Author)

  4. Implementation of a risk assessment tool based on a probabilistic safety assessment developed for radiotherapy practices

    Energy Technology Data Exchange (ETDEWEB)

    Paz, A.; Godinez, V.; Lopez, R., E-mail: abpaz@cnsns.gob.m [Comision Nacional de Seguridad Nuclear y Salvaguardias, Dr. Barragan No. 779, Col. Narvarte, 03020 Mexico D. F. (Mexico)

    2010-10-15

    The present work describes the implementation process and main results of the risk assessment to the radiotherapy practices with Linear Accelerators (Linac), with cobalt 60, and with brachytherapy. These evaluations were made throughout the risk assessment tool for radiotherapy practices SEVRRA (risk evaluation system for radiotherapy), developed at the Mexican National Commission in Nuclear Safety and Safeguards derived from the outcome obtained with the Probabilistic Safety Analysis developed at the Ibero-American Regulators Forum for these radiotherapy facilities. The methodology used is supported by risk matrices method, a mathematical tool that estimates the risk to the patient, radiation workers and public from mechanical failures, mis calibration of the devices, human mistakes, and so. The initiating events are defined as those undesirable events that, together with other failures, can produce a delivery of an over-dose or an under-dose of the medical prescribed dose, to the planned target volume, or a significant dose to non prescribed human organs. Initiating events frequency and reducer of its frequency (actions intended to avoid the accident) are estimated as well as robustness of barriers to those actions, such as mechanical switches, which detect and prevent the accident from occurring. The spectrum of the consequences is parameterized, and the actions performed to reduce the consequences are identified. Based on this analysis, a software tool was developed in order to simplify the evaluations to radiotherapy installations and it has been applied as a first step forward to some Mexican installations, as part of a national implementation process, the final goal is evaluation of all Mexican facilities in the near future. The main target and benefits of the SEVRRA implementation are presented in this paper. (Author)

  5. Radiotherapy equipment and departments in the European countries: final results from the ESTRO-HERO survey.

    Science.gov (United States)

    Grau, Cai; Defourny, Noémie; Malicki, Julian; Dunscombe, Peter; Borras, Josep M; Coffey, Mary; Slotman, Ben; Bogusz, Marta; Gasparotto, Chiara; Lievens, Yolande; Kokobobo, Arianit; Sedlmayer, Felix; Slobina, Elena; Feyen, Karen; Hadjieva, Tatiana; Odrazka, Karel; Grau Eriksen, Jesper; Jaal, Jana; Bly, Ritva; Chauvet, Bruno; Willich, Normann; Polgar, Csaba; Johannsson, Jakob; Cunningham, Moya; Magrini, Stefano; Atkocius, Vydmantas; Untereiner, Michel; Pirotta, Martin; Karadjinovic, Vanja; Levernes, Sverre; Sladowski, Krystol; Lurdes Trigo, Maria; Šegedin, Barbara; Rodriguez, Aurora; Lagerlund, Magnus; Pastoors, Bert; Hoskin, Peter; Vaarkamp, Jaap; Cleries Soler, Ramon

    2014-08-01

    Documenting the distribution of radiotherapy departments and the availability of radiotherapy equipment in the European countries is an important part of HERO - the ESTRO Health Economics in Radiation Oncology project. HERO has the overall aim to develop a knowledge base of the provision of radiotherapy in Europe and build a model for health economic evaluation of radiation treatments at the European level. The aim of the current report is to describe the distribution of radiotherapy equipment in European countries. An 84-item questionnaire was sent out to European countries, principally through their national societies. The current report includes a detailed analysis of radiotherapy departments and equipment (questionnaire items 26-29), analyzed in relation to the annual number of treatment courses and the socio-economic status of the countries. The analysis is based on validated responses from 28 of the 40 European countries defined by the European Cancer Observatory (ECO). A large variation between countries was found for most parameters studied. There were 2192 linear accelerators, 96 dedicated stereotactic machines, and 77 cobalt machines reported in the 27 countries where this information was available. A total of 12 countries had at least one cobalt machine in use. There was a median of 0.5 simulator per MV unit (range 0.3-1.5) and 1.4 (range 0.4-4.4) simulators per department. Of the 874 simulators, a total of 654 (75%) were capable of 3D imaging (CT-scanner or CBCT-option). The number of MV machines (cobalt, linear accelerators, and dedicated stereotactic machines) per million inhabitants ranged from 1.4 to 9.5 (median 5.3) and the average number of MV machines per department from 0.9 to 8.2 (median 2.6). The average number of treatment courses per year per MV machine varied from 262 to 1061 (median 419). While 69% of MV units were capable of IMRT only 49% were equipped for image guidance (IGRT). There was a clear relation between socio-economic status, as

  6. Radiotherapy equipment and departments in the European countries: Final results from the ESTRO-HERO survey

    International Nuclear Information System (INIS)

    Grau, Cai; Defourny, Noémie; Malicki, Julian; Dunscombe, Peter; Borras, Josep M.; Coffey, Mary; Slotman, Ben; Bogusz, Marta; Gasparotto, Chiara; Lievens, Yolande; Kokobobo, Arianit; Sedlmayer, Felix; Slobina, Elena; Feyen, Karen; Hadjieva, Tatiana; Odrazka, Karel; Eriksen, Jesper Grau; Jaal, Jana; Bly, Ritva; Chauvet, Bruno

    2014-01-01

    Background: Documenting the distribution of radiotherapy departments and the availability of radiotherapy equipment in the European countries is an important part of HERO – the ESTRO Health Economics in Radiation Oncology project. HERO has the overall aim to develop a knowledge base of the provision of radiotherapy in Europe and build a model for health economic evaluation of radiation treatments at the European level. The aim of the current report is to describe the distribution of radiotherapy equipment in European countries. Methods: An 84-item questionnaire was sent out to European countries, principally through their national societies. The current report includes a detailed analysis of radiotherapy departments and equipment (questionnaire items 26–29), analyzed in relation to the annual number of treatment courses and the socio-economic status of the countries. The analysis is based on validated responses from 28 of the 40 European countries defined by the European Cancer Observatory (ECO). Results: A large variation between countries was found for most parameters studied. There were 2192 linear accelerators, 96 dedicated stereotactic machines, and 77 cobalt machines reported in the 27 countries where this information was available. A total of 12 countries had at least one cobalt machine in use. There was a median of 0.5 simulator per MV unit (range 0.3–1.5) and 1.4 (range 0.4–4.4) simulators per department. Of the 874 simulators, a total of 654 (75%) were capable of 3D imaging (CT-scanner or CBCT-option). The number of MV machines (cobalt, linear accelerators, and dedicated stereotactic machines) per million inhabitants ranged from 1.4 to 9.5 (median 5.3) and the average number of MV machines per department from 0.9 to 8.2 (median 2.6). The average number of treatment courses per year per MV machine varied from 262 to 1061 (median 419). While 69% of MV units were capable of IMRT only 49% were equipped for image guidance (IGRT). There was a clear

  7. Quarantine treatment in eggs of Stenoma catenifer Walsingham (Lepidoptera: Elachistidae), with gamma radiation of Cobalt-60

    International Nuclear Information System (INIS)

    Silva, L.K.F.; Arthur, V.; Nava, D.E.; Parra, J.R.P.

    2006-01-01

    The objective of this work has been to determine the lethal dose of gamma radiation of Cobalt-60 for the Stenoma catenifer eggs. For the irradiation of the eggs an irradiador Gammacell-220 (CO60) was utilized, (Rate dose: 1.054 kGY/h). The doses were: 0, 25, 50, 75, 100, 125 and 150 Gy, 90 eggs/dose (six repetitions). The number of caterpillars emerged was evaluated, and the survivors growed in seeds of avocado. The adults obtained were coupled with normal insects, growed in boxes with double face paper containing the food (10% honey) and a fruit of avocado. The experimental design was totally random, being the data submitted to the analysis of the varianza and the averages compared by the test of Tukey (P=5%). The emergence of caterpillars from the treated eggs with dose of 0, 25 and 50 Gy was verified. The dose of 50 Gy caused deformation in the caterpillars emerged. The effect of the gamma radiation in the viability of the eggs was proportional to the dose increase. The adults from the eggs dealt with 25 Gy presented non viabilty of 92,85 and 100% for male and female, respectively. A radiation gamma of 75 Gy is recommended for treatment quarantine for avocado fruits infested with of S. catenifer eggs

  8. Dependence of the risk of encephalopathy on the radiotherapy volume after combined surgery and radiotherapy of invasive pituitary tumors

    International Nuclear Information System (INIS)

    Rauhut, F.; Stolke, D.; Stuschke, M.; Sack, H.

    2002-01-01

    The effectiveness of radiotherapy in reducing tumor recurrence of pituitary adenomas is well documented. On the other hand, the risk of side effects to the surrounding central nervous system normal tissue should not be underestimated. This retrospective study includes 58 patients with subtotally resected pituitary tumors. Photon from a 5,7 MV linear accelerator of a 60 cobalt unit with a source-isocenter distance of 80 cm were used throughout for treatment. The doses per fraction ranged from 45 Gy to 60 Gy. For a direct comparison of the different fractionation schedules, the biological effective total dose with 2 Gy per fraction was calculated for all the different application schemes with doses per fraction longer or smaller than 2 Gy. To do this, a fractionation sensitivity of the normal cerebral tissue by an □/□ value of 2 Gy was assumed. Encephalopathy developed in 17 cases (28 percentage) after follow-up times of more than 5 years. Pathological CT- or MRI-findings were seen in 13 cases. Two factors were important for the genesis of radiogenic encephalopathy: 1. Multivariate analysis revealed that the risk of encephalopathy was associated with the radiation volume. 2. The location of the upper field border line was the strongest prognostic factor associated with the risk of encephalopathy (p < 0.05). (author)

  9. Intraplaque Hemorrhage and the Plaque Surface in Carotid Atherosclerosis: The Plaque At RISK Study (PARISK)

    NARCIS (Netherlands)

    van Dijk, A. C.; Truijman, M. T. B.; Hussain, B.; Zadi, T.; Saiedie, G.; de Rotte, A. A. J.; Liem, M. I.; van der Steen, A. F. W.; Daemen, M. J. A. P.; Koudstaal, P. J.; Nederkoorn, P. J.; Hendrikse, J.; Kooi, M. E.; van der Lugt, A.

    2015-01-01

    An important characteristic of vulnerable plaque, intraplaque hemorrhage, may predict plaque rupture. Plaque rupture can be visible on noninvasive imaging as a disruption of the plaque surface. We investigated the association between intraplaque hemorrhage and disruption of the plaque surface. We

  10. Blood doping by cobalt. Should we measure cobalt in athletes?

    Directory of Open Access Journals (Sweden)

    Guidi Gian

    2006-07-01

    Full Text Available Abstract Background Blood doping is commonplace in competitive athletes who seek to enhance their aerobic performances through illicit techniques. Presentation of the hypothesis Cobalt, a naturally-occurring element with properties similar to those of iron and nickel, induces a marked and stable polycythemic response through a more efficient transcription of the erythropoietin gene. Testing the hypothesis Although little information is available so far on cobalt metabolism, reference value ranges or supplementation in athletes, there is emerging evidence that cobalt is used as a supplement and increased serum concentrations are occasionally observed in athletes. Therefore, given the athlete's connatural inclination to experiment with innovative, unfair and potentially unhealthy doping techniques, cobalt administration might soon become the most suited complement or surrogate for erythropoiesis-stimulating substances. Nevertheless, cobalt administration is not free from unsafe consequences, which involve toxic effects on heart, liver, kidney, thyroid and cancer promotion. Implications of the hypothesis Cobalt is easily purchasable, inexpensive and not currently comprehended within the World Anti-Doping Agency prohibited list. Moreover, available techniques for measuring whole blood, serum, plasma or urinary cobalt involve analytic approaches which are currently not practical for antidoping laboratories. Thus more research on cobalt metabolism in athletes is compelling, along with implementation of effective strategies to unmask this potentially deleterious doping practice

  11. Efficacy of triphala mouth rinse (aqueous extracts) on dental plaque and gingivitis in children.

    Science.gov (United States)

    Bhattacharjee, Ritesh; Nekkanti, Sridhar; Kumar, Nikesh G; Kapuria, Ketan; Acharya, Shashidhar; Pentapati, Kalyana C

    2015-08-01

    The aim of the present study was to evaluate the efficacy of triphala mouth rinse (aqueous) in the reduction of plaque and gingivitis among children. The study was a randomized, double-blinded, controlled trial, with a total of 60 school children (n = 30 in each group; triphala and chlorhexidine groups). Plaque and gingival indices were used to evaluate baseline and follow-up plaque and gingivitis. A total of 57 children completed the study. Both chlorhexidine and triphala groups showed significantly lower mean gingival and plaque index scores at follow up than baseline (P gingival index between the two groups (P = 0.826). The percentage change in the mean plaque index was significantly higher in the chlorhexidine group compared to the triphala group (P = 0.048). The effectiveness of triphala in the reduction of plaque and gingivitis was comparable to chlorhexidine, and can be used for short-term purposes without potential side-effects. It is a cost-effective alternative in reducing plaque and gingivitis. © 2014 Wiley Publishing Asia Pty Ltd.

  12. Sorption of 60Co on a synthetic titanosilicate analogue of the mineral penkvilksite-2O and antimonysilicate

    International Nuclear Information System (INIS)

    Koudsi, Y.; Dyer, A.

    2001-01-01

    The ability of two different types of synthetic inorganic ion-exchangers to sorb radioactive cobalt-60 using a batch-type method was studied. The two materials examined were the analogue of the natural titanosilicate penkvilksite-2O (AM-3) and a synthetic antimonysilicate. Ion-exchange experiments were performed with solutions labelled with radioactive cobalt ( 60 Co). The sorption of 60 Co onto the two samples materials were compared in terms of distribution coefficient (K d ), sorption percentage and cobalt quantity removed in mg per gram weight of the material. Several parameters were investigated viz. contact time, cobalt concentration, and sorbent concentration. It was found that the batch factor and cobalt concentration had a significant influence on the sorption of cobalt onto both of the materials. This was associated with the difference in pH generated by suspensions of the materials in water which was alkaline for the penkvilksite-2O analogue, and acid for the synthetic antimonysilicate. (author)

  13. Testing of cobalt-free alloys for valve applications using a special test loop

    International Nuclear Information System (INIS)

    Benhamou, C.

    1992-01-01

    Considering that use of cobalt alloys should be avoided as far as possible in PWR components, a programme aimed at establishing the performance of cobalt-free alloys has been performed for valve applications, where cobalt alloys are mainly used. Referring to past work, two types of cobalt-free alloys were selected: Ni-Cr-B-Si and Ni-Cr-Fe alloys. Cobalt-free valves' behaviour has been evaluated comparatively with cobalt valves by implementation of a programme in a special PWR test loop. At the issue of the loop test programme, which included endurance, thermal shock and erosion tests, cobalt-free alloys candidate to replace cobalt alloys are proposed in relation with valve type (globe valve and swing check valve). The following was established: (i) Colmonoy 4-26 (Ni-Cr-B-Si alloy) and Cenium Z20 (Ni-Cr-Fe alloy) deposited by plasma arc process were found suitable for use in 3inch swing check valves; (ii) for integral parts acting as guide rings, Nitronic 60 and Cesium Z20/698 were tested successfully; (iii) for small-bore components such as 2inch globe valves, no solution can yet be proposed; introduction of cobalt-free alloys is dependent on the development of automatic advanced arc surfacing techniques applied to small-bore components

  14. Development of a multichannel dosimeter for radiotherapy; Desenvolvimento de um dosimetro multicanal para radioterapia

    Energy Technology Data Exchange (ETDEWEB)

    Menezes, Claudio Jose Mesquita

    2000-06-01

    In radiotherapy, verification of the patient dose is of great important for the success of the treatment. Uncertainties in the evaluation of this dose can produce serious complications such as the loss of the control of the disease and damage to normal tissue. Semiconductor detectors present advantages over other types of radiation detectors such as ionization chambers and thermoluminescent dosimeters including small dimensions, high sensitivity and fast response. In this work, a multichannel dosimetric system is linear with dose, for a 6 MV x-ray beam and also with a beam of cobalt-60 gamma rays. The coefficients of determination of the calibration curves were better then 0,9998 in all cases. The four sensors presented similar response with the dose for different field sizes. The variation of the response was smaller than 1%. In a related study, depth dose was measured, and the results showed a good agreement compared to theoretical values. The angular response of the detectors showed a variation of 7% for angles of 45 deg C. Using the Anderson Random phantom, dose at the isocenter was determined from measurements of the surface dose. From the results obtained it can be concluded that the dosimetric system developed is adequate for the evaluation of many parameters in radiation fields used in radiotherapy. This system can be used to measure the patient entrance dose under treatment conditions, and the equipment can be used in the radiotherapy quality assurance program. (author)

  15. Monte Carlo simulation for treatment planning optimization of the COMS and USC eye plaques using the MCNP4C code

    International Nuclear Information System (INIS)

    Jannati Isfahani, A.; Shokrani, P.; Raisali, Gh.

    2010-01-01

    Ophthalmic plaque radiotherapy using I-125 radioactive seeds in removable episcleral plaques is often used in management of ophthalmic tumors. Radioactive seeds are fixed in a gold bowl-shaped plaque and the plaque is sutured to the scleral surface corresponding to the base of the intraocular tumor. This treatment allows for a localized radiation dose delivery to the tumor with a minimum target dose of 85 Gy. The goal of this study was to develop a Monte Carlo simulation method for treatment planning optimization of the COMS and USC eye plaques. Material and Methods: The MCNP4C code was used to simulate three plaques: COMS-12mm, COMS-20mm, and USC ≠9 with I-125 seeds. Calculation of dose was performed in a spherical water phantom (radius 12 mm) using a 3D matrix with a size of 12 voxels in each dimension. Each voxel contained a sphere of radius 1 mm. Results: Dose profiles were calculated for each plaque. Isodose lines were created in 2 planes normal to the axes of the plaque, at the base of the tumor and at the level of the 85 Gy isodose in a 7 day treatment. Discussion and Conclusion: This study shows that it is necessary to consider the following tumor properties in design or selection of an eye plaque: the diameter of tumor base, its thickness and geometric shape, and the tumor location with respect to normal critical structures. The plaque diameter is selected by considering the tumor diameter. Tumor thickness is considered when selecting the seed parameters such as their number, activity and distribution. Finally, tumor shape and its location control the design of following parameters: the shape and material of the plaque and the need for collimation.

  16. Effect of Cobalt Supplementation on Performance of growing Calves

    Directory of Open Access Journals (Sweden)

    V.Nagabhushana

    Full Text Available The experiment was conducted to study the effect of critical supplementation of wheat straw with cobalt on fibre utilization and nutrient utilization in growing cross-bred male calves. Twenty-one crossbred (HF X Local male growing calves of 3-4 months age were fed with wheat straw based diet consisting without (Co0 and with 1 (Co1 and 6 (Co6 ppm cobalt as cobaltous chloride. There was no significant difference in intake of wheat straw, concentrate and DMI between the three groups and the ratio between concentrate and wheat straw was maintained at 40:60 irrespective of dietary level of cobalt. Similarly, average cumulative body weight, net gain in body weight or feed efficiency did not differ significantly between treatments. No significant effect was observed on the digestibility of dry matter, organic matter, crude protein, ether extract and fibre constituents like NDF, ADF, hemicellulose or cellulose by supplementation of 1 and 6 ppm Co to the diet of growing calves. Balance of nutrients such as Nitrogen, Calcium and Phosphorus was similar and positive in all the treatment groups. TDN and DCP values of the experimental diets remained almost similar irrespective of dietary level of cobalt. [Veterinary World 2008; 1(10.000: 299-302

  17. Concentration of radioactive cobalt by seaweeds in the food chain

    International Nuclear Information System (INIS)

    Nakahara, Motokazu; Koyanagi, Taku; Saiki, Masamichi

    1976-01-01

    On the pathway of radioactive substances in marine environments, seaweeds play an important role because of their higher concentration factors for many radionuclides and because they constitute a link of food chain in the sea. In the present work, uptake, distribution and excretion of radioactive cobalt were studied on several kinds of seaweeds by radioisotope tracer experiments under laboratory conditions and concentration factors were calculated. The concentration factors were also estimated from the results of stable cobalt determination by activation analysis or atomic absorption spectrometry on seaweeds and seawater, and compared with the results of tracer expts. The seaweeds showed the species specificity for the concentration of stable and radioactive cobalt with diverse values of concentration factors and biological half-lives. The transfer of radioactive cobalt in the food chain from contaminated seaweeds to mollusca was examined by feeding abalones, Haliotis discus, with four kinds of seaweed labelled with 60 Co and observing retention. Absorption rate for radioactive cobalt by abalones calculated at two days after feeding showed diverse values depending upon the species of seaweed, as follows: 47% through Laminaria japonica and Ulva pertusa, 31% through Undaria pinnatifida and 26 through Eisenia bicyclis, respectively. From the results, it was assumed that the accumulation of radioactive cobalt by mollusca is affected by the species of seaweeds as food. A very high concentration of ingested radioactive cobalt in the midgut gland was seen on the autoradiograph of abalone samples. (auth.)

  18. Concentration of radioactive cobalt by seaweeds in the food chain

    International Nuclear Information System (INIS)

    Nakahara, M.; Koyanagi, T.; Saiki, M.

    1975-01-01

    On the pathway of radioactive substances in marine environments, seaweeds play an important role because of their higher concentration factors for many radionuclides and because they constitute a link in the food chain. In the present work, uptake, distribution and excretion of radioactive cobalt were studied on several kinds of seaweeds by radioisotope tracer experiments under laboratory conditions and concentration factors were calculated. The concentration factors were also estimated from the results of stable cobalt determination by activation analysis or atomic absorption spectrometry on seaweeds and seawater, and compared with the results of tracer experiments. The seaweeds showed the species specificity for the concentration of stable and radioactive cobalt with diverse values of concentration factors and biological half-lives. The transfer of radioactive cobalt in the food chain from contaminated seaweeds to mollusca was examined by feeding abalones, Haliotis discus, with four kinds of seaweed labelled with 60 Co and observing retention. Absorption rate for radioactive cobalt by abalones calculated at two days after feeding showed diverse values depending upon the species of seaweed, as follows: 47% through Laminaria japonica and Ulva pertusa, 31% through Undaria pinnatifida and 26% through Eisenia bicyclis, respectively. From the results, it was assumed that the accumulation of radioactive cobalt by mollusca is affected by the species of seaweeds as food. A very high concentration of ingested radioactive cobalt in the midgut gland was seen on the autoradiograph of abalone samples. (author)

  19. Cobalt release from inexpensive jewellery

    DEFF Research Database (Denmark)

    Thyssen, Jacob Pontoppidan; Jellesen, Morten Stendahl; Menné, Torkil

    2010-01-01

    . Conclusions: This study showed that only a minority of inexpensive jewellery purchased in Denmark released cobalt when analysed with the cobalt spot test. As fashion trends fluctuate and we found cobalt release from dark appearing jewellery, cobalt release from consumer items should be monitored in the future......Objectives: The aim was to study 354 consumer items using the cobalt spot test. Cobalt release was assessed to obtain a risk estimate of cobalt allergy and dermatitis in consumers who would wear the jewellery. Methods: The cobalt spot test was used to assess cobalt release from all items...

  20. PENGARUH RADIASI SINAR GAMMA COBALT-60 TERHADAP SIFAT MORFOLOGI DAN AGRONOMI KETIGA VARIETAS JAGUNG (ZEA MAYS L.

    Directory of Open Access Journals (Sweden)

    Makhziah

    2017-04-01

    Full Text Available Mutation is one of the ways to improve genetic variation in plant breeding so the target traits were more easily obtained. Grains of three varieties of maize (Bisma, Madura local, and Gumarang were treated with gamma 60cobalt irradiation doses (0, 100, 200, and 300 Gy before sowing then planted in a split plot randomized block design with three replication, to be evaluated for their morphology and agronomic traits. The Main plot was cultivars and sub plot was gamma radiation rates. There was no interaction between gamma rates and cultivars of maize, but increasing of gamma rates caused decreasing of some traits. Some traits such as plant height and leaves number were decreased significantly when gamma rate increased 100 to 300 Gy as well yield components such as grain weight and grain number per ear. Gamma 200 caused produce more ears than other rates. Bisma exhibited greater performance than Madura and Gumarang both of morphology and agronomic traits.

  1. Studied by electron paramagnetic resonance (EPR) of polymethyl methacrylate (PMMA) irradiated with gamma photons from cobalt 60

    International Nuclear Information System (INIS)

    Jalali, Hajer

    2013-01-01

    Ionizing radiation is radiation able to deposit enough energy in the material through which they pass to create ionization. These ionizing radiations, when mastered, have many practical uses beneficial (areas of health, industry ...). Gamma rays are emitted by radioactive nuclei. The objective of our work is the study of polymethyl methacrylate (PMMA) irradiated by gamma photons from cobalt-60. To study the technique of radio spectroscopy (9 to 10Hz) electron paramagnetic resonance EPR is used. This technique is specific to characterize transient free radicals involved in chemical reactions such as oxidation, combustion, polymerization reactions ... We analyzed the EPR spectra three batch KS, EB, and JF our dosimeter according to the dose (high and low) and showed that the dosimetric response can be represented in exponential form (high dose) and linear form (low dose). We also studied the kinetics of decay of the EPR signal as a function of time (fading) and showed that the responses relating to stabilize after 20 min of irradiation.

  2. Commissioning of Theratron phoenix telecobalt machine and its performance assessment

    International Nuclear Information System (INIS)

    Rajendran, M.; Reddy, K.D.; Reddy, R.M.; Reddy, J.M.; Reddy, B.V.N.; Kumar, K.; Gopi, S.; Rajan, Dharani; Janardhanan

    2002-01-01

    Teletherapy machines like cobalt-60 unit and linear accelerator are extensively used for radiotherapy. Theratron phoenix machines have been installed. A brief report on the performance of this machine is presented

  3. Atherosclerotic plaque volume and composition in symptomatic carotid arteries assessed with multidetector CT angiography; relationship with severity of stenosis and cardiovascular risk factors

    International Nuclear Information System (INIS)

    Rozie, S.; Weert, T.T. de; Monye, C. de; Homburg, P.J.; Tanghe, H.L.J.; Lugt, A. van der; Dippel, D.W.J.

    2009-01-01

    The purpose of this study was to examine the volume and the composition of atherosclerotic plaque in symptomatic carotid arteries and to investigate the relationship between these plaque features and the severity of stenosis and the presence of cardiovascular risk factors. One hundred patients with cerebrovascular symptoms underwent CT angiography. We measured plaque volume (PV) and the relative contribution of plaque components (calcifications, fibrous tissue, and lipid) in the symptomatic artery. The contribution of different components was measured as the number of voxels within defined ranges of HU values (calcification >130 HU, fibrous tissue 60-130 HU, lipid core <60 HU). Fifty-seven patients had atherosclerotic plaque in the symptomatic carotid artery. The severity of stenosis and PV were moderately correlated. Age and smoking were independently related to PV. Patients with hypercholesterolemia had significantly less lipid and more calcium in their plaques than patients without hypercholesterolemia. Other cardiovascular risk factors were not significantly related to PV or plaque composition. Luminal stenosis of the carotid artery partly reflects the amount of atherosclerotic carotid disease. Plaque volume and plaque composition are associated with cardiovascular risk factors. (orig.)

  4. Atherosclerotic plaque volume and composition in symptomatic carotid arteries assessed with multidetector CT angiography; relationship with severity of stenosis and cardiovascular risk factors

    Energy Technology Data Exchange (ETDEWEB)

    Rozie, S.; Weert, T.T. de; Monye, C. de; Homburg, P.J.; Tanghe, H.L.J.; Lugt, A. van der [Erasmus MC, University Medical Center Rotterdam, Departments of Radiology, Rotterdam (Netherlands); Dippel, D.W.J. [Erasmus MC, University Medical Center Rotterdam, Department of Neurology, PO Box 2040, Rotterdam (Netherlands)

    2009-09-15

    The purpose of this study was to examine the volume and the composition of atherosclerotic plaque in symptomatic carotid arteries and to investigate the relationship between these plaque features and the severity of stenosis and the presence of cardiovascular risk factors. One hundred patients with cerebrovascular symptoms underwent CT angiography. We measured plaque volume (PV) and the relative contribution of plaque components (calcifications, fibrous tissue, and lipid) in the symptomatic artery. The contribution of different components was measured as the number of voxels within defined ranges of HU values (calcification >130 HU, fibrous tissue 60-130 HU, lipid core <60 HU). Fifty-seven patients had atherosclerotic plaque in the symptomatic carotid artery. The severity of stenosis and PV were moderately correlated. Age and smoking were independently related to PV. Patients with hypercholesterolemia had significantly less lipid and more calcium in their plaques than patients without hypercholesterolemia. Other cardiovascular risk factors were not significantly related to PV or plaque composition. Luminal stenosis of the carotid artery partly reflects the amount of atherosclerotic carotid disease. Plaque volume and plaque composition are associated with cardiovascular risk factors. (orig.)

  5. No calcium-fluoride-like deposits detected in plaque shortly after a sodium fluoride mouthrinse.

    Science.gov (United States)

    Vogel, G L; Tenuta, L M A; Schumacher, G E; Chow, L C

    2010-01-01

    Plaque 'calcium-fluoride-like' (CaF(2)-like) and fluoride deposits held by biological/bacterial calcium fluoride (Ca-F) bonds appear to be the source of cariostatic concentrations of fluoride in plaque fluid. The aim of this study was to quantify the amounts of plaque fluoride held in these reservoirs after a sodium fluoride rinse. 30 and 60 min after a 228 microg/g fluoride rinse, plaque samples were collected from 11 volunteers. Each sample was homogenized, split into 2 aliquots (aliquots 1 and 2), centrifuged, and the recovered plaque fluid combined and analyzed using microelectrodes. The plaque mass from aliquot 1 was retained. The plaque mass from aliquot 2 was extracted several times with a solution having the same fluoride, calcium and pH as the plaque fluid in order to extract the plaque CaF(2)-like deposits. The total fluoride in both aliquots was then determined. In a second experiment, the extraction completeness was examined by applying the above procedure to in vitro precipitates containing known amounts of CaF(2)-like deposits. Nearly identical fluoride concentrations were found in both plaque aliquots. The extraction of the CaF(2)-like precipitates formed in vitro removed more than 80% of these deposits. The results suggest that either CaF(2)-like deposits were not formed in plaque or, if these deposits had been formed, they were rapidly lost. The inability to form persistent amounts of CaF(2)-like deposits in plaque may account for the relatively rapid loss of plaque fluid fluoride after the use of conventional fluoride dentifrices or rinses. (c) 2010 S. Karger AG, Basel.

  6. Development of the irradiation facility SIBO INRA/Tangier, Morocco by upgrading cobalt-60 in a temporary pool and enhancing safety and control features

    Directory of Open Access Journals (Sweden)

    Mohammed Mouhib

    2017-12-01

    Full Text Available An automatic control system is one of the most important parts of an irradiation facility. The level of this control is always maintained to comply with safety procedures during routine work in this field. Also sometimes it is limited to the minimum level of regulation required due to economical aspects; some commercial systems are generally made by manufacturers of industrial facilities and considered affordable by irradiators. In some cases specific irradiation facilities tailor their control systems to their needs. For this kind of irradiator the control system can be developed and upgraded according to personal and industrial experiences. These upgrading procedures are also used by others to develop their systems. The objective of this paper is to share a local experience in upgrading security, safety systems and the use of cobalt-60 for the irradiator. It is a composite experiment at SIBO INRA/Tangier, Morocco and concerns the: (i upgrade of cobalt-60 in a temporary pool in the SIBO irradiator in Tangier. This operation was conducted in collaboration with the International Atomic Energy Agency (IAEA and was a success story of 2014 according to the general conference of IAEA; (ii safety and technical upgrade of the system in the SIBO irradiator made in collaboration with IAEA; (iii installation and upgrade of the security system in accordance with the Global Threat Reduction Programme (GTRP to reduce the threat of a Radiological Dispersal Device (RDD in collaboration with The United States Department of Energy’s National Nuclear Security Administration (NNSA.

  7. Analysis of Complex Coronary Plaque in Multidetector Computed Tomography: Comparison with Conventional Coronary Angiography

    International Nuclear Information System (INIS)

    Kim, Dong Hyun; Bang, Duck Won; Cho, Yoon Haeng; Suk, Eun Ha

    2011-01-01

    To delineate complex plaque morphology in patients with stable angina using coronary computed tomographic angiography (CTA). 36 patients with complex plaques proven by conventional coronary angiography (CAG), who had taken CTA for evaluation of typical angina, were enrolled in this study. Intravascular ultrasonography (IVUS) was performed in 14 patients (16 lesions). We compared CTA with CAG for plaque features and analyzed vascular cutoff, intraluminal filling defect in a patent vessel, irregularity of plaque, and ulceration. Also, the density of plaque was evaluated on CTA. CAG and CTA showed complex morphology in 44 cases (100%) and 34 cases, (77%), respectively, with features including abrupt vessel cutoff (27 vs. 16%, κ=0.57), intraluminal filling defect (32 vs. 30%, κ=0.77), irregularity (75 vs. 52%, κ=0.52), and ulceration (16 vs. 11%, κ=0.60). CTA indicated that the complex lesions were hypodense (mean 66 ± 21 Houndsfield Units). CTA is a very accurate and useful non-invasive imaging modality for evaluating complex plaque in patients with typical angina.

  8. Analysis of Complex Coronary Plaque in Multidetector Computed Tomography: Comparison with Conventional Coronary Angiography

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Dong Hyun [Dept. of Radiology, Soonchunhyang University Hospital, Bucheon (Korea, Republic of); Bang, Duck Won; Cho, Yoon Haeng [Dept. of Internal Medicine, Soonchunhyang University Hospital, Bucheon (Korea, Republic of); Suk, Eun Ha [Dept. of Anesthyesiology and Pain Medicine, Asan Medical Center, Seoul (Korea, Republic of)

    2011-04-15

    To delineate complex plaque morphology in patients with stable angina using coronary computed tomographic angiography (CTA). 36 patients with complex plaques proven by conventional coronary angiography (CAG), who had taken CTA for evaluation of typical angina, were enrolled in this study. Intravascular ultrasonography (IVUS) was performed in 14 patients (16 lesions). We compared CTA with CAG for plaque features and analyzed vascular cutoff, intraluminal filling defect in a patent vessel, irregularity of plaque, and ulceration. Also, the density of plaque was evaluated on CTA. CAG and CTA showed complex morphology in 44 cases (100%) and 34 cases, (77%), respectively, with features including abrupt vessel cutoff (27 vs. 16%, {kappa}=0.57), intraluminal filling defect (32 vs. 30%, {kappa}=0.77), irregularity (75 vs. 52%, {kappa}=0.52), and ulceration (16 vs. 11%, {kappa}=0.60). CTA indicated that the complex lesions were hypodense (mean 66 {+-} 21 Houndsfield Units). CTA is a very accurate and useful non-invasive imaging modality for evaluating complex plaque in patients with typical angina.

  9. Thermal effect on structure organizations in cobalt-fullerene nanocomposition.

    Science.gov (United States)

    Lavrentiev, Vasily; Vacik, Jiri; Naramoto, Hiroshi; Sakai, Seiji

    2010-04-01

    Effect of deposition temperature (Ts) on structure of Co-C60 nanocomposite (NC) prepared by simultaneous deposition of cobalt and fullerene on sapphire is presented. The NC structure variations with Ts increasing from room temperature (RT) to 400 degrees C have been analyzed using scanning electron microscopy (SEM), atomic force microscopy (AFM) and Raman spectroscopy. AFM and SEM show granule-like structure of the Co-C60 film. The mixture film deposited at RT includes the hills on the surface suggesting accumulation of internal stress during phase separation. Raman spectra show 25 cm(-1) downshift of Ag(2) C60 peak suggesting -Co-C60- polymerization in C60-based matrix of the NC film. Analysis of Raman spectra has revealed existence of amorphous carbon (a-C) in the NC matrix that argues C60 decomposition. The Ts increase to 200 degrees C causes the surface hills smoothing. In parallel, downshift of the Ag(2) peak decreases to 16 cm(-1) that implies more pronounced phase separation and lower -Co-C60- polymerization efficiency. Also, amount of a-C content slightly increases. Further Ts increasing to 400 degrees C changes the NC structure dramatically. AFM shows evident enlargement of the granules. According to Raman spectra the high Ts deposition yields pronounced C60 decomposition increasing the a-C content. Features of a-C Raman peak imply nucleation of graphitic islands at the NC interfaces. Abundant decomposition of C60 in the mixture film deposited at 400 degrees C is referred to cobalt catalytic effect.

  10. Assessment of vulnerable plaque composition by matching the deformation of a parametric plaque model to measured plaque deformation.

    Science.gov (United States)

    Baldewsing, Radj A; Schaar, Johannes A; Mastik, Frits; Oomens, Cees W J; van der Steen, Antonius F W

    2005-04-01

    Intravascular ultrasound (IVUS) elastography visualizes local radial strain of arteries in so-called elastograms to detect rupture-prone plaques. However, due to the unknown arterial stress distribution these elastograms cannot be directly interpreted as a morphology and material composition image. To overcome this limitation we have developed a method that reconstructs a Young's modulus image from an elastogram. This method is especially suited for thin-cap fibroatheromas (TCFAs), i.e., plaques with a media region containing a lipid pool covered by a cap. Reconstruction is done by a minimization algorithm that matches the strain image output, calculated with a parametric finite element model (PFEM) representation of a TCFA, to an elastogram by iteratively updating the PFEM geometry and material parameters. These geometry parameters delineate the TCFA media, lipid pool and cap regions by circles. The material parameter for each region is a Young's modulus, EM, EL, and EC, respectively. The method was successfully tested on computer-simulated TCFAs (n = 2), one defined by circles, the other by tracing TCFA histology, and additionally on a physical phantom (n = 1) having a stiff wall (measured EM = 16.8 kPa) with an eccentric soft region (measured EL = 4.2 kPa). Finally, it was applied on human coronary plaques in vitro (n = 1) and in vivo (n = 1). The corresponding simulated and measured elastograms of these plaques showed radial strain values from 0% up to 2% at a pressure differential of 20, 20, 1, 20, and 1 mmHg respectively. The used/reconstructed Young's moduli [kPa] were for the circular plaque EL = 50/66, EM = 1500/1484, EC = 2000/2047, for the traced plaque EL = 25/1, EM = 1000/1148, EC = 1500/1491, for the phantom EL = 4.2/4 kPa, EM = 16.8/16, for the in vitro plaque EL = n.a./29, EM = n.a./647, EC = n.a./1784 kPa and for the in vivo plaque EL = n.a./2, EM = n.a./188, Ec = n.a./188 kPa.

  11. Model for Estimating Power and Downtime Effects on Teletherapy Units in Low-Resource Settings

    Directory of Open Access Journals (Sweden)

    Rachel McCarroll

    2017-10-01

    Full Text Available Purpose: More than 6,500 megavoltage teletherapy units are needed worldwide, many in low-resource settings. Cobalt-60 units or linear accelerators (linacs can fill this need. We have evaluated machine performance on the basis of patient throughput to provide insight into machine viability under various conditions in such a way that conclusions can be generalized to a vast array of clinical scenarios. Materials and Methods: Data from patient treatment plans, peer-reviewed studies, and international organizations were combined to assess the relative patient throughput of linacs and cobalt-60 units that deliver radiotherapy with standard techniques under various power and maintenance support conditions. Data concerning the frequency and duration of power outages and downtime characteristics of the machines were used to model teletherapy operation in low-resource settings. Results: Modeled average daily throughput was decreased for linacs because of lack of power infrastructure and for cobalt-60 units because of limited and decaying source strength. For conformal radiotherapy delivered with multileaf collimators, average daily patient throughput over 8 years of operation was equal for cobalt-60 units and linacs when an average of 1.83 hours of power outage occurred per 10-hour working day. Relative to conformal treatments delivered with multileaf collimators on the respective machines, the use of advanced techniques on linacs decreased throughput between 20% and 32% and, for cobalt machines, the need to manually place blocks reduced throughput up to 37%. Conclusion: Our patient throughput data indicate that cobalt-60 units are generally best suited for implementation when machine operation might be 70% or less of total operable time because of power outages or mechanical repair. However, each implementation scenario is unique and requires consideration of all variables affecting implementation.

  12. Cobalt release from inexpensive jewellery: has the use of cobalt replaced nickel following regulatory intervention?

    Science.gov (United States)

    Thyssen, Jacob Pontoppidan; Jellesen, Morten S; Menné, Torkil; Lidén, Carola; Julander, Anneli; Møller, Per; Johansen, Jeanne Duus

    2010-08-01

    Before the introduction of the EU Nickel Directive, concern was raised that manufacturers of jewellery might turn from the use of nickel to cobalt following the regulatory intervention on nickel exposure. The aim was to study 354 consumer items using the cobalt spot test. Cobalt release was assessed to obtain a risk estimate of cobalt allergy and dermatitis in consumers who would wear the jewellery. The cobalt spot test was used to assess cobalt release from all items. Microstructural characterization was made using scanning electron microscope (SEM) and energy-dispersive spectroscopy (EDS). Cobalt release was found in 4 (1.1%) of 354 items. All these had a dark appearance. SEM/EDS was performed on the four dark appearing items which showed tin-cobalt plating on these. This study showed that only a minority of inexpensive jewellery purchased in Denmark released cobalt when analysed with the cobalt spot test. As fashion trends fluctuate and we found cobalt release from dark appearing jewellery, cobalt release from consumer items should be monitored in the future. Industries may not be fully aware of the potential cobalt allergy problem.

  13. Analysis of Magnetic Resonance Image Signal Fluctuations Acquired During MR-Guided Radiotherapy.

    Science.gov (United States)

    Breto, Adrian L; Padgett, Kyle R; Ford, John C; Kwon, Deukwoo; Chang, Channing; Fuss, Martin; Stoyanova, Radka; Mellon, Eric A

    2018-03-28

    Magnetic resonance-guided radiotherapy (MRgRT) is a new and evolving treatment modality that allows unprecedented visualization of the tumor and surrounding anatomy. MRgRT includes daily 3D magnetic resonance imaging (MRI) for setup and rapidly repeated near real-time MRI scans during treatment for target tracking. One of the more exciting potential benefits of MRgRT is the ability to analyze serial MRIs to monitor treatment response or predict outcomes. A typical radiation treatment (RT) over the span of 10-15 minutes on the MRIdian system (ViewRay, Cleveland, OH) yields thousands of "cine" images, each acquired in 250 ms. This unique data allows for a glimpse in image intensity changes during RT delivery. In this report, we analyze cine images from a single fraction RT of a glioblastoma patient on the ViewRay platform in order to characterize the dynamic signal changes occurring during RT therapy. The individual frames in the cines were saved into DICOM format and read into an MIM image analysis platform (MIM Software, Cleveland, OH) as a time series. The three possible states of the three Cobalt-60 radiation sources-OFF, READY, and ON-were also recorded. An in-house Java plugin for MIM was created in order to perform principal component analysis (PCA) on each of the datasets. The analysis resulted in first PC, related to monotonous signal increase over the course of the treatment fraction. We found several distortion patterns in the data that we postulate result from the perturbation of the magnetic field due to the moving metal parts in the platform while treatment was being administered. The largest variations were detected when all Cobalt-60 sources were OFF. During this phase of the treatment, the gantry and multi-leaf collimators (MLCs) are moving. Conversely, when all Cobalt-60 sources were in the ON position, the image signal fluctuations were minimal, relating to very little mechanical motion. At this phase, the gantry, the MLCs, and sources are fixed

  14. Calculation of uncertainties in the protocol of dosimetry for Co 60 beams in Radiotherapy; Calculo de incertidumbres en el protocolo de dosimetria para haces de Co 60 en Radioterapia

    Energy Technology Data Exchange (ETDEWEB)

    Velazquez M, S.; Carrera M, F.; Sanchez S, J. [Hospital Juan Ramon Jimenez, Ronda Norte s/n 21005 Huelva (Spain)

    1998-12-31

    The objective in this work is to show how the uncertainty is possible to know in the determination of the absorbed dose in Co 60 photon beams and to establish in a rational form, tolerance levels for this. It is took as base the spanish protocol of dosimetry in Radiotherapy. We have been centered in a Co 60 beam. We utilized the statistical theory of little samples. We allowed to suggest a new approach about the treatment of the tolerance levels and the uncertainty of the measurement. After two years of experience in the practical hospitable application we have gotten to put around 1 % uncertainty in the absolute dosimetry of the Co 60 beam. The presented protocol allows to execute the accuracy requirements in the determination of absorbed doses. (Author)

  15. Results of radiotherapy and vitamin E in the treatment of peyronie's disease

    International Nuclear Information System (INIS)

    Rodrigues, Cristine I.; Njo, K. Hian; Karim, Abdul B. M. F.

    1995-01-01

    Purpose: A retrospective analysis of 38 patients with Peyronie's disease treated with primary radiotherapy in the period of 1975-1993. Methods and Materials: Important complaints were curvature of the penis during erection for 92% of the patients, painful erection for 68%, and problems with sexual intercourse for 37.5%. Average size of all indurated plaques was 2.5 cm. The average pretreatment duration of symptoms was 9.5 months. All 38 patients were irradiated with orthovoltage radiotherapy (200 and 250 kV photons) with a total dose of 9 Gy in 5 alternating days (regimen A). Because of minimal response, 16 patients were irradiated again with another 9 Gy in 5 days and finally received 18 Gy (regimen B). Results: With regimen A, a satisfying improvement was achieved for the majority of the patients: 65% experienced less penile pain during erection, 40% reported less curvature of the penis, and 47% experienced an improvement of their sex life. With the higher dose of regimen B there was an additional improvement for a minority of the patients: 25% reported less pain during erection, 21% had less curvature, and 29% experienced an improved sex life. With regimen A, pain improvement was statistically significantly superior when compared to regimen B. For all other improvements (curvature, sexual intercourse, and induration) no dose-response relation could be demonstrated between regimen A and the higher dose regimen B. No patient experienced any radiation-induced morbidity. After evaluating regimen A and regimen B, the overall result was that 76% experienced less pain, 60% reported an improved sex life, and 48% had a diminished curvature during erection. Conclusion: From this analysis it can be concluded that the distressing symptoms of Peyronie's disease can be treated successfully with radiotherapy. Radiotherapy proves to be a safe, noninvasive treatment method without causing morbidity. Low-dose radiotherapy with only a few fractions is recommended for an effective

  16. Cobalt release from implants and consumer items and characteristics of cobalt sensitized patients with dermatitis

    DEFF Research Database (Denmark)

    Thyssen, Jacob Pontoppidan; Menne, Torkil; Liden, Carola

    2012-01-01

    -containing dental alloys and revised hip implant components.Results. Six of eight dental alloys and 10 of 98 revised hip implant components released cobalt in the cobalt spot test, whereas none of 50 mobile phones gave positive reactions. The clinical relevance of positive cobalt test reactions was difficult......-tested dermatitis patients in an attempt to better understand cobalt allergy.Materials and methods. 19 780 dermatitis patients aged 4-99 years were patch tested with nickel, chromium or cobalt between 1985 and 2010. The cobalt spot test was used to test for cobalt ion release from mobile phones as well as cobalt...

  17. Delayed airway stenosis after radiotherapy for head and neck cancer

    Energy Technology Data Exchange (ETDEWEB)

    Yuta, Atsushi; Tatematsu, Masanori; Ishinaga, Hajime; Harada, Teruhiko; Majima, Yuichi [Mie Univ., Tsu (Japan). School of Medicine

    2002-03-01

    Seven cases of delayed airway stenosis after radiotherapy for early staged head and neck cancers during 1989 and 1999 were evaluated (aged 54-77 yrs, 6 male and a female). The cases included five glottic laryngeal cancers (T1a, T1b, and three T2), a subglottic laryngeal cancer, and an unknown origin, but strongly suspected laryngeal cancer, with neck metastasis. Radio injury was found from 3 months to 47 months after radiotherapy. {sup 60}Co for radiotherapy was used in all seven cases, although {sup 60}Co radionuclide was changed to Liniac in 1997. The total dose was 60 Gy for 3 cases, and 70 Gy for 4 cases. Tracheostomy was performed in 3 cases due to bilateral vocal cord impairment. Background, treatment, and response to radiotherapy were compared to those of 90 patients of a control group with early staged laryngeal cancer who did not fail radiation injury during the same period. As a result, radionuclide ({sup 60}Co), total dose, cervical surgery, antiinflammatory drugs, laryngeal edema during radiotherapy were risk factors. The intensity and the period of mucositis by radiotherapy was important for indicating delayed airway stenosis. (author)

  18. Delayed airway stenosis after radiotherapy for head and neck cancer

    International Nuclear Information System (INIS)

    Yuta, Atsushi; Tatematsu, Masanori; Ishinaga, Hajime; Harada, Teruhiko; Majima, Yuichi

    2002-01-01

    Seven cases of delayed airway stenosis after radiotherapy for early staged head and neck cancers during 1989 and 1999 were evaluated (aged 54-77 yrs, 6 male and a female). The cases included five glottic laryngeal cancers (T1a, T1b, and three T2), a subglottic laryngeal cancer, and an unknown origin, but strongly suspected laryngeal cancer, with neck metastasis. Radio injury was found from 3 months to 47 months after radiotherapy. 60 Co for radiotherapy was used in all seven cases, although 60 Co radionuclide was changed to Liniac in 1997. The total dose was 60 Gy for 3 cases, and 70 Gy for 4 cases. Tracheostomy was performed in 3 cases due to bilateral vocal cord impairment. Background, treatment, and response to radiotherapy were compared to those of 90 patients of a control group with early staged laryngeal cancer who did not fail radiation injury during the same period. As a result, radionuclide ( 60 Co), total dose, cervical surgery, antiinflammatory drugs, laryngeal edema during radiotherapy were risk factors. The intensity and the period of mucositis by radiotherapy was important for indicating delayed airway stenosis. (author)

  19. Radiological safety aspects during handling of adjuster rod (cobalt-60) samples at Cirus

    International Nuclear Information System (INIS)

    Yadav, R.K.B.; Prasad, S.K.; Khuspe, R.R.; Babu, K.S.; Kamble, M.K.; Deshpande, S.B.; Srivastava, Alok; Ramesh, N.; Sharma, R.C.

    2008-01-01

    Cobalt -60 produced from the irradiation of the 59 Co capsules in adjuster rod of Cirus is used in many medical and industrial applications such as radiation therapy, sterilization of agricultural products, sterilization of medical equipment, industrial gamma exposure devices, nucleonic gauging sources etc. Two adjuster rods used for adjusting small reactivity loads (3.5 mk at 40 MW) in reactor contain thirty 59 Co slugs each. The 59 Co slugs are in the form of small capsules. These slugs were irradiated for nearly 3 years of full power operation. Since the amount of activity handled in the adjuster rod is very high (35 - 40 kCi), adequate radiological safety coverage is to be provided during the transfer of adjuster rod from the reactor pile to Tray Rod Facility (TRF) and during remote handling and loading of adjuster rod samples in shipping flask at TRF. Radiation fields observed are 0.4 - 3.0 Gy/h. In Cirus, falling of Adjuster rod from vertical flask at top of pile could result in declaration of evacuation emergency due to potential hazards associated with the high radiation field (∼26 Gy/h at 1m) of 60 Co slugs. Entire process of remote handling is viewed through lead glass and movement of samples is carried out with the help of a pair of master slave manipulator (MSM) arms. TRF with full samples give a radiation background of 0.2 - 20 mGy/h, requiring control of movement of personnel in the area. This paper explains in detail about the health physics aspects during handling of adjuster rod from reactor pile to TRF and back to pile, unloading and loading of radioisotope samples, operational radiation protection experience gained and collective dose consumed for the above transfer and loading job. The collective dose consumed in the handling of two adjuster rods is 8.7 per-mSv. (author)

  20. Effects of cobalt-60 low doses radiation on beam, rice and radish seeds

    International Nuclear Information System (INIS)

    Kikuchi, O.K.

    1987-01-01

    The effects of cobalt-60 gamma radiation on seeds of bean (Phaseolus vulgaris L.), rice (Oryza sativa L.) and radish (Raphanus sativus L.) were studied. Bean and rice seeds were irradiated with 3.5 and 7.7 Gy (32 Gy/h). There was an apparent acceleration on rice seed germination with 3.5 Gy when they were stored for 6 days after irradiation, but the same dose caused a delay when the store time was 1 day. Bean seeds germination was not modified by 3.5 and 7.7 Gy, but the fresh and dry weight of young plants showed an increase, mainly due the major quantity of water in the embryonic axis. Bean seeds were irradiated with 0.5 and 2.0 Gy (30 Gy/h). Seeds germination showed a slight delay irradiating with 0.5 Gy, while height, fresh and dry weight and primary leaves area of the young plants as well as number of nodes, leaves, flowers, beans and seeds were not modified after irradiation with 0.5 and 2.0 Gy. Radish seeds irradiated with 10 and 30 Gy at dose rates of 4.5, 22.5 and 45.0 Gy/h showed a germination delay and fresh and dry weight values for young plants leaves lower than control. Roots of totally developed plants showed no modifications in weight, volume, mean diameter, lenght and in the amount of soluble reducing sugar. (author)

  1. Preoperative cobalt{sup 60} irradiation delays the healing of rectal anastomoses in rats

    Energy Technology Data Exchange (ETDEWEB)

    Fang, C.B.; Klug, W.A.; Capelhuchnik, P. [Santa Casa de Misericordia de Sao Paulo, SP (Brazil). Faculdade de Ciencias Medicas. Dept. de Cirurgia]. E-mail: colon.reto@terra.com.br

    2005-06-15

    The healing of colorectal anastomoses after irradiation therapy continues to be a major concern. The authors evaluated the healing of rectal anastomoses in a rat model after a preoperative 500-c Gy dose of cobalt 60 irradiation. Thirty-six male Wistar rats were divided into two equal groups: control (group A), and irradiation group (group B). Group B received a single 500-c Gy dose of irradiation, and a rectal resection and end-to-end anastomosis was performed in both groups on the seventh day after irradiation. Parameters of the healing process included bursting pressure and collagen content on the fifth, seventh, and fourteenth days after surgery. In the irradiation group, the mean bursting pressure on the fifth, seventh, and fourteenth days was 116, 218, and 273 mmHg, respectively. The collagen content assessed by histomorphometry was 9.0, 20.8, and 32%, respectively. In contrast, the control group had a mean bursting pressure of 175, 225 and 263 mmHg, and a collagen content of 17.8, 28.1, and 32.1%, respectively. The adverse effect of irradiation on healing was detectable only on the fifth postoperative day, as demonstrated by lower bursting pressure (P < 0.013) and collagen content (P < 0.008). However, there was no failure of anastomotic healing such as leakage or dehiscence due to irradiation. We conclude that a single preoperative 500-c Gy dose of irradiation delays the healing of rectal anastomosis in rats. (author)

  2. Induced chlorophyll variation in pineapple c v. 'queen' by gamma irradiation (60Cobalt)

    International Nuclear Information System (INIS)

    Valencia, Lolita DC.

    2012-01-01

    Irradiation using gamma rays ( 60 Cobalt) coupled with in vitro culture techniques was undertaken to induce variation or mutation in pineapple. Calli from crown meristem tips of pineapple cv 'Queen' [Ananas comosus (L.) Merr.] were initiated using Murashiege and Skoog's basal meduim supplemented with 10mg/liter 4-amino-3,5,6-trichloro-2-pyrodinecarboxylic acid (Picloram). High percentage of growth and shoot proliferation was observed in basal medium supplemented with 50 μM benzene adenine purine (BAP) and 10 μM gibberrelic acid (GA) after 8 weeks in vitro. Regenerants derived from shoots using different doses of gamma rays (0, 5, 10, 15, 20, 25 and 30 Gy) were evaluated under laboratory conditions. Of the different doses, 15 Gy produced the most variegation in young shoots (chlorophyll variants) maintained in vitro. The variants appeared to have yellow and green color combinations of the young leaves of pineapple 'Queen' variety. When transplanted inside the greenhouse, high percentage of plantlets survival was observed, ranging from 90-95%. Of the different irradiation doses, variegation in young leaves was observed at 15, 20, 25 and 30 Gy. Further assessment on the effect of irradiation is currently being unertaken under screen house conditions. The variants produced could serve a basis for selection of ornamental-type pineapple. In addition, protocols developed on the use of in vitro culture techniques could be utilized as a tool for induced mutation breeding in pineapple. (author)

  3. SU-E-T-328: Dosimetric Impact of Cobalt-Chrome Stabilization Hardware in Paraspinal Radiation Therapy

    International Nuclear Information System (INIS)

    Tang, G; LoSasso, T; Saleh, Z; Mechalakos, J; Lim, S; Lovelock, D; Laufer, I; Bilsky, M; Yamada, J

    2015-01-01

    Purpose: Due to saturation, high density materials Result in an apparent density of 3.2 g/cm 3 in CT images. The true density of traditional titanium stabilization rods (∼4.4 g/cm 3 ) is typically ignored in treatment planning. This may not be acceptable for new cobalt-chrome rods with a density of 8.5 g/cm 3 . This study reports the dosimetric impact of cobalt-chrome rods in paraspinal radiotherapy. Methods: For titanium and cobalt-chrome rods, two planning studies were done for both IMRT and VMAT in Varian Eclipse using AAA. 1) The effect of planning without assigning the true rod density was assessed by comparing plans generated with the apparent density and recalculated with the true density for titanium and cobalt-chrome. 2) To test if TPS can compensate for high density rods during optimization. Furthermore, TPS calculation accuracy was verified using MapCheck for a single 20 x 10 cm 2 field. The MapCheck was incrementally shifted to achieve measurement resolution of 1 mm. Results: PTV coverage was ∼0.3% and ∼4.7% lower in plans that were recalculated with the true rod density of titanium and cobalt-chrome, respectively. PTV coverage can be maintained if the correct density is used in optimization. Measurements showed that TPS overestimated the dose locally by up to 11% for cobalt-chrome rods and up to 4% for titanium rods if the density is incorrect. With density corrected, maximum local differences of 6% and 3% were seen for cobalt-chrome and titanium rods, respectively. At 2 cm beneath a rod, electrons scattered from the side of the rod increased the lateral dose and diminished as depth increases. TPS was not able to account for this effect properly even with the true rod density assigned. Conclusion: Neglecting the true density of cobalt-chrome rods can cause under coverage to the PTV. Assigning the correct density during treatment planning can minimize unexpected decrease in PTV dose

  4. Carotid plaque age is a feature of plaque stability inversely related to levels of plasma insulin.

    Directory of Open Access Journals (Sweden)

    Sara Hägg

    Full Text Available BACKGROUND: The stability of atherosclerotic plaques determines the risk for rupture, which may lead to thrombus formation and potentially severe clinical complications such as myocardial infarction and stroke. Although the rate of plaque formation may be important for plaque stability, this process is not well understood. We took advantage of the atmospheric (14C-declination curve (a result of the atomic bomb tests in the 1950s and 1960s to determine the average biological age of carotid plaques. METHODOLOGY/PRINCIPAL FINDING: The cores of carotid plaques were dissected from 29 well-characterized, symptomatic patients with carotid stenosis and analyzed for (14C content by accelerator mass spectrometry. The average plaque age (i.e. formation time was 9.6±3.3 years. All but two plaques had formed within 5-15 years before surgery. Plaque age was not associated with the chronological ages of the patients but was inversely related to plasma insulin levels (p = 0.0014. Most plaques were echo-lucent rather than echo-rich (2.24±0.97, range 1-5. However, plaques in the lowest tercile of plaque age (most recently formed were characterized by further instability with a higher content of lipids and macrophages (67.8±12.4 vs. 50.4±6.2, p = 0.00005; 57.6±26.1 vs. 39.8±25.7, p<0.0005, respectively, less collagen (45.3±6.1 vs. 51.1±9.8, p<0.05, and fewer smooth muscle cells (130±31 vs. 141±21, p<0.05 than plaques in the highest tercile. Microarray analysis of plaques in the lowest tercile also showed increased activity of genes involved in immune responses and oxidative phosphorylation. CONCLUSIONS/SIGNIFICANCE: Our results show, for the first time, that plaque age, as judge by relative incorporation of (14C, can improve our understanding of carotid plaque stability and therefore risk for clinical complications. Our results also suggest that levels of plasma insulin might be involved in determining carotid plaque age.

  5. Interaction between sulfur and lead in toxicity, iron plaque formation and lead accumulation in rice plant.

    Science.gov (United States)

    Yang, Junxing; Liu, Zhiyan; Wan, Xiaoming; Zheng, Guodi; Yang, Jun; Zhang, Hanzhi; Guo, Lin; Wang, Xuedong; Zhou, Xiaoyong; Guo, Qingjun; Xu, Ruixiang; Zhou, Guangdong; Peters, Marc; Zhu, Guangxu; Wei, Rongfei; Tian, Liyan; Han, Xiaokun

    2016-06-01

    Human activities have resulted in lead and sulfur accumulation in paddy soils in parts of southern China. A combined soil-sand pot experiment was conducted to investigate the influence of S supply on iron plaque formation and Pb accumulation in rice (Oryza sativa L.) under two Pb levels (0 and 600 mg kg(-1)), combined with four S concentrations (0, 30, 60, and 120 mg kg(-1)). Results showed that S supply significantly decreased Pb accumulation in straw and grains of rice. This result may be attributed to the enhancement of Fe plaque formation, decrease of Pb availability in soil, and increase of reduced glutathione (GSH) in rice leaves. Moderate S supply (30 mg kg(-1)) significantly increased Fe plaque formation on the root surface and in the rhizosphere, whereas excessive S supply (60 and 120 mg kg(-1)) significantly decreased the amounts of iron plaque on the root surface. Sulfur supply significantly enhanced the GSH contents in leaves of rice plants under Pb treatment. With excessive S application, the rice root acted as a more effective barrier to Pb accumulation compared with iron plaque. Excessive S supply may result in a higher monosulfide toxicity and decreased iron plaque formation on the root surface during flooded conditions. However, excessive S supply could effectively decrease Pb availability in soils and reduce Pb accumulation in rice plants. Copyright © 2016 Elsevier Inc. All rights reserved.

  6. A new inexpensive customized plaque for choroidal melanoma iodine-125 plaque therapy

    International Nuclear Information System (INIS)

    Vine, A.K.; Tenhaken, R.K.; Diaz, R.F.; Maxson, B.B.; Lichter, A.S.

    1989-01-01

    The authors have developed a new inexpensive precious metal alloy plaque for use in customized iodine-125 plaque therapy. Each plaque is formed from two flat circular gold/palladium foils which are used in dental crown work. Using a simple manual mechanism, the two forms are stamped over a customized acrylic die shaped to the dimensions of the tumor base plus a 2-mm margin. Completed plaques consist of a back wall, a 2-mm side wall, and a 1.5-mm wide lip with holes for suture placement. Advantages include: simple construction from inexpensive components, customized shape, and iodine seeds that are readily visible on plane radiographs

  7. Scanning electron microscopy of mouse intestinal mucosa after cobalt 60 and D-T neutron irradiation

    International Nuclear Information System (INIS)

    Hamlet, R.; Carr, K.R.; Toner, P.G.; Nias, A.H.W.

    1976-01-01

    The stem-cell population of the intestinal crypt is an important model system in experimental radiobiology. Standardized techniques have been developed to allow quantitation of the response of crypt cells to radiation injury following doses of 0 to 2 krad of D-T neutrons or 60 Co γ rays. These techniques rely on the identification of regenerating crypt cells three-and-a-half days after irradiation. The results were expressed as the number of regenerating crypts per circumference of small intestine, as determined by conventional histological examination; the more profound the injury, the smaller the the crypt count. The practical relevance of crypt-counting techniques to clinical radiotherapy is limited by their relative insensitivity; the dose levels commonly used in fractionated radiotherapy produced no detectable response. Scanning electron microscopy of the mucosal surface provided a more sensitive measure of radiation injury. The earliest detectable changes occurred at the level of 300 rad of γ radiation, well below the threshold of the crypt-counting technique. At around 1,000 rad, where the first drop in crypt counts occurred, there were well-marked morphological changes which became more severe with increasing dose levels. Some differences have been observed between the morphological effects of γ and neutron irradiation at points of radiobiological equivalence in terms of crypt counts (using RBE value of about 2). The changes observed may reflect more than the disruption of epithelial cell kinetics. Mucosal morphology is the total expression of many different biological parameters of which the regenerative ability of the crypt cells is only one. The surface microanatomy of the gut may be the most sensitive indicator of radiation injury which is conveniently available for study. (author)

  8. Scanning electron microscopy of mouse intestinal mucosa after cobalt 60 and D-T neutron irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Hamlet, R [Belvidere Hospital, Glasgow (UK). Institute of Radiotherapeutics and Oncology; Carr, K R; Toner, P G; Nias, A H.W.

    1976-07-01

    The stem-cell population of the intestinal crypt is an important model system in experimental radiobiology. Standardized techniques have been developed to allow quantitation of the response of crypt cells to radiation injury following doses of 0 to 2 krad of D-T neutrons or /sup 60/Co ..gamma.. rays. These techniques rely on the identification of regenerating crypt cells three-and-a-half days after irradiation. The results were expressed as the number of regenerating crypts per circumference of small intestine, as determined by conventional histological examination; the more profound the injury, the smaller the the crypt count. The practical relevance of crypt-counting techniques to clinical radiotherapy is limited by their relative insensitivity; the dose levels commonly used in fractionated radiotherapy produced no detectable response. Scanning electron microscopy of the mucosal surface provided a more sensitive measure of radiation injury. The earliest detectable changes occurred at the level of 300 rad of ..gamma.. radiation, well below the threshold of the crypt-counting technique. At around 1,000 rad, where the first drop in crypt counts occurred, there were well-marked morphological changes which became more severe with increasing dose levels. Some differences have been observed between the morphological effects of ..gamma.. and neutron irradiation at points of radiobiological equivalence in terms ofCrypt counts (using RBE value of about 2). The changes observed may reflect more than the disruption of epithelial cell kinetics. Mucosal morphology is the total expression of many different biological parameters of which the regenerative ability of the crypt cells is only one. The surface microanatomy of the gut may be the most sensitive indicator of radiation injury which is conveniently available for study.

  9. Study of the dosimetric response of Gallium Nitride (GaN): modeling, simulation and characterization on radiotherapy

    International Nuclear Information System (INIS)

    Wang, Ruoxi

    2015-01-01

    The work in this thesis has the objective to increase the measurement precision of the dosimetry based on the Gallium Nitride (GaN) transducer and develop its applications on radiotherapy. The study includes the aspects of modeling, simulation and characterization of this response in external radiotherapy and brachytherapy. In modeling, we have proposed two approaches to model the GaN transducer's response in external radiotherapy. For the first approach, a model has been built based on experimental data, while separating the primary and scattering component of the beam. For the second approach, we have adopted a response model initially developed for the silicon diodes for the GaN radioluminescent transducer. We have also proposed an original concept of bi-media dosimetry which evaluates the dose in tissue according to different responses from two media without prior information on the conditions of irradiation. This concept has been shown by Monte Carlo simulation. Moreover, for High Dose Rate brachytherapy, the response of GaN transducer irradiated by iridium 192 and cobalt 60 sources has been evaluated by Monte Carlo simulation and confirmed by the measurements. Studies on the property characterization of GaN radioluminescent transducer has been carried out with these sources as well. An instrumented phantom prototype with GaN probe has been developed for the HDR brachytherapy quality control. It allows a real-time verification of the physics parameters of a treatment (source dwell position, source dwell time, source activity). (author) [fr

  10. Fission product gamma-ray sources as an alternative to cobalt-60 sources for sewage sludge sterilization

    International Nuclear Information System (INIS)

    Herrnberger, V.R.D.

    1975-01-01

    The sterilization of sewage sludge is now performed successfully using 60 Co gamma-ray sources. The question arises whether more economic gamma-ray sources exist that could replace the 60 Co source. The following types of sources are considered: Spent fuel elements; mixtures of solidified fission products; and isolated solidified fission products such as 134 / 137 Cs. For a particular irradiation plant the specific source costs (S.Fr./Ci) and their contribution to the irradiation costs for 1 m 3 of sewage irradiated to a dose of 250 krad(S.Fr./m 3 ) are determined and compared with the costs of a plant using a 60 Co source. The encapsulation costs and the effect of the gamma absorption of the source are taken into account. Different encapsulation and source management techniques are reviewed to find the most economic for each source type. A spent fuel element irradiation facility is recommended for use either in combination with a sewage water purification plant or as part of a power reactor station where it replaces the storage water pool for the spent fuel elements. Additional source capsules are not envisaged, as long as double-walled source containers are used. The fission product mixtures are enclosed in double-walled capsules of two different forms: Small cylindrical rods and hollow cylinders. For caesium and cobalt cylindrical rods only are used. The main conclusions of the study are that the highest irradiation costs arise from the use of a fission product mixture source. The costs are, however, only 15% above those of a 60 Co plant. To be competitive the flow-rate has to be adapted to the decreasing activity of the source, resulting in a reduction to 20% within ten years of source utilization. The integrated irradiation plant with a spent fuel element source offers irradiation costs comparable with those of a 60 Co plant, if the flow-rate is constant during one year of source utilization. The irradiation costs are reduced to 25% of those of a 60 Co plant

  11. Quantitative coronary plaque analysis predicts high-risk plaque morphology on coronary computed tomography angiography: results from the ROMICAT II trial.

    Science.gov (United States)

    Liu, Ting; Maurovich-Horvat, Pál; Mayrhofer, Thomas; Puchner, Stefan B; Lu, Michael T; Ghemigian, Khristine; Kitslaar, Pieter H; Broersen, Alexander; Pursnani, Amit; Hoffmann, Udo; Ferencik, Maros

    2018-02-01

    Semi-automated software can provide quantitative assessment of atherosclerotic plaques on coronary CT angiography (CTA). The relationship between established qualitative high-risk plaque features and quantitative plaque measurements has not been studied. We analyzed the association between quantitative plaque measurements and qualitative high-risk plaque features on coronary CTA. We included 260 patients with plaque who underwent coronary CTA in the Rule Out Myocardial Infarction/Ischemia Using Computer Assisted Tomography (ROMICAT) II trial. Quantitative plaque assessment and qualitative plaque characterization were performed on a per coronary segment basis. Quantitative coronary plaque measurements included plaque volume, plaque burden, remodeling index, and diameter stenosis. In qualitative analysis, high-risk plaque was present if positive remodeling, low CT attenuation plaque, napkin-ring sign or spotty calcium were detected. Univariable and multivariable logistic regression analyses were performed to assess the association between quantitative and qualitative high-risk plaque assessment. Among 888 segments with coronary plaque, high-risk plaque was present in 391 (44.0%) segments by qualitative analysis. In quantitative analysis, segments with high-risk plaque had higher total plaque volume, low CT attenuation plaque volume, plaque burden and remodeling index. Quantitatively assessed low CT attenuation plaque volume (odds ratio 1.12 per 1 mm 3 , 95% CI 1.04-1.21), positive remodeling (odds ratio 1.25 per 0.1, 95% CI 1.10-1.41) and plaque burden (odds ratio 1.53 per 0.1, 95% CI 1.08-2.16) were associated with high-risk plaque. Quantitative coronary plaque characteristics (low CT attenuation plaque volume, positive remodeling and plaque burden) measured by semi-automated software correlated with qualitative assessment of high-risk plaque features.

  12. Dose calculation method with 60-cobalt gamma rays in total body irradiation

    International Nuclear Information System (INIS)

    Scaff, Luiz Alberto Malaguti

    2001-01-01

    Physical factors associated to total body irradiation using 60 Co gamma rays beams, were studied in order to develop a calculation method of the dose distribution that could be reproduced in any radiotherapy center with good precision. The method is based on considering total body irradiation as a large and irregular field with heterogeneities. To calculate doses, or doses rates, of each area of interest (head, thorax, thigh, etc.), scattered radiation is determined. It was observed that if dismagnified fields were considered to calculate the scattered radiation, the resulting values could be applied on a projection to the real size to obtain the values for dose rate calculations. In a parallel work it was determined the variation of the dose rate in the air, for the distance of treatment, and for points out of the central axis. This confirm that the use of the inverse square law is not valid. An attenuation curve for a broad beam was also determined in order to allow the use of absorbers. In this work all the adapted formulas for dose rate calculations in several areas of the body are described, as well time/dose templates sheets for total body irradiation. The in vivo dosimetry, proved that either experimental or calculated dose rate values (achieved by the proposed method), did not have significant discrepancies. (author)

  13. Studies of the yields of 57Fe(II)-species produced after the EC-decay and of 60Co(II)-species produced in the (n, γ) reaction in cobalt(III) coordination compounds

    International Nuclear Information System (INIS)

    Sano, Hirotoshi; Harada, Masayuki; Endo, Kazutoyo

    1978-01-01

    The yields of 57 Fe(II)-species produced after EC-decay were compared with those of 60 Co(II)-species produced in the 59 Co(n, γ) 60 Co reaction for twelve cobalt(III) coordination compounds. The results indicate that the radiochemical yield of 60 Co(II)-species correlates with the yield of 57 Fe(II)-species except in the case of [Co(NH 3 ) 6 ] 2 (CrO 4 ) 3 . The anomalously low yield of 57 Fe(II)-species in [Co(NH 3 ) 6 ] 2 (CrO 4 ) 3 is ascribed to the reaction of chromate anions with ammine ligands initiated by the nuclear transformation in a solid. (author)

  14. Efficacy of Methotrexate in patients with plaque type psoriasis

    Science.gov (United States)

    Haider, Sabiqa; Wahid, Zarnaz; Najam-us-Saher; Riaz, Farzana

    2014-01-01

    Objective: To assess the efficacy of Methotrexate in patients with plaque type psoriasis. Methods: This descriptive study was conducted in the department of Dermatology, Civil Hospital Karachi from September 2009 to March 2010. Seventy three patients between 18 to 50 years of age suffering from plaque type psoriasis with PASI score of >10 were included in the study after taking the informed consent. Oral methotrexate in a dose of 7.5 mg/week was given for 8 weeks. The data collected included demographic profile (age and gender), duration of disease, site of involvement, size of plaque, severity of plaque measured by Psoriasis Area and Severity Index (PASI) score before starting the treatment and at the end of treatment. Efficacy was labeled with a PASI score of ≤5 at the end of 8 weeks. Results: Out of 73 patients there were 45 (61.6%) males and 28 (38.4%) females. The mean ±SD age was 40.0±12.6 years. The mean baseline PASI score showed clear and comparable improvement from a mean ± SD PASI score of 14.8±4.2 to 4.9±4.3.Twenty nine (40%) patients had an almost complete remission during the 8 weeks of treatment. Partial remission was achieved in 44 (60%) patients. The clearance time for psoriasis ranged from 5-7 weeks (mean 6±0.89 weeks). Conclusion: Treatment with methotrexate for chronic plaque psoriasis brings satisfactory disease control and improved quality of life. PMID:25225524

  15. Generalized morphea following radiotherapy for an intracranial tumor

    Directory of Open Access Journals (Sweden)

    Shrenik Balegar

    2016-01-01

    Full Text Available Morphea is a localized scleroderma variety which can be circumscribed or generalized and is characterized by sclerotic plaques developing on trunk and limbs. Surgery and radiation have been implicated as etiological factors for the development of morphea. Majority of the radiation-induced morphea cases have occurred in patients with breast cancer. The affected areas have been generally restricted to the area of radiation and nearby surrounding area in most of the reported cases. We hereby report a case of a 27-year-old male who developed radiation-induced progressive generalized morphea after getting radiotherapy for an intracranial tumor. His condition improved after dexamethasone-cyclophosphamide pulse therapy. With increased incidence of cancer worldwide and radiotherapy as a modality of treatment, it is imperative to follow the patient and look for the development of morphea which itself is a debilitating disease.

  16. Design and Simulation of 5-DOF Vision-Based Manipulator to Increase Radiation Safety for Industrial Cobalt-60 Irradiators

    International Nuclear Information System (INIS)

    Solyman, A.E.; Keshk, A.B.; Sharshar, K.A.; Roman, M.R.

    2016-01-01

    Robotics has proved its efficiency in nuclear and radiation fields. Computer vision is one of the advanced approaches used to enhance robotic efficiency. The current work investigates the possibility of using a vision-based controlled arm robot to collect the fallen hot Cobalt-60 capsules inside wet storage pool of industrial irradiator. A 5-DOF arm robot is designed and vision algorithms are established to pick the fallen capsules on the bottom surface of the storage pool, read the information printed on its edge (cap) and move it to a safe storage place. Two object detection approaches are studied; RGB-based filter and background subtraction technique. Vision algorithms and camera calibration are done using MATLAB/SIMULINK program. Robot arm forward and inverse kinematics are developed and programmed using an embedded micro controller system. Experiments show the validity of the proposed system and prove its success. The collecting process will be done without interference of operators, hence radiation safety will be increased.

  17. Plaque disruption by coronary computed tomographic angiography in stable patients vs. acute coronary syndrome: a feasibility study.

    Science.gov (United States)

    Bilolikar, Abhay N; Goldstein, James A; Madder, Ryan D; Chinnaiyan, Kavitha M

    2016-03-01

    This study was designed to determine whether coronary CT angiography (CTA) can detect features of plaque disruption in clinically stable patients and to compare lesion prevalence and features between stable patients and those with acute coronary syndrome (ACS). We retrospectively identified patients undergoing CTA, followed by invasive coronary angiography (ICA) within 60 days. Quantitative 3-vessel CTA lesion analysis was performed on all plaques ≥25% stenosis to assess total plaque volume, low attenuation plaque (LAP, disruption, including ulceration and intra-plaque dye penetration (IDP). ICA was employed as a reference standard for disruption. A total of 145 (94 ACS and 51 stable) patients were identified. By CTA, plaque disruption was evident in 77.7% of ACS cases. Although more common among those with ACS, CTA also detected plaque disruption in 37.3% of clinically stable patients (P disruption as determined by CTA. Though the prevalence of plaque disruption is less than patients with ACS, these findings support the concept that some clinically stable patients may harbour 'silent' disrupted plaques. These findings may have implications for detection of 'at risk' plaques and patients. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2015. For permissions please email: journals.permissions@oup.com.

  18. Main aspects in licensing of a type B(U) package design for the transport of 12.95 PBq of cobalt 60

    International Nuclear Information System (INIS)

    Lopez Vietri, J.R.; Novo, R.G.; Bianchi, A.J.

    1995-01-01

    This paper points out the relevant technical issues related to the licensing process, of a type B(U) package design, with cylindrical form and 9.3 ton mass, approved by the Argentine Competent Authority for the transport of 12.95 PBq of cobalt 60 as special form radioactive material. It is briefly described the heat transfer analysis, the structural performance under impulsive loads and the shielding calculation under both normal and accidental conditions of transport, as well as the comparative analysis of the results obtained from design, pre-operational tests and independent evaluation performed by the Argentine Competent Authority to verify the compliance with the Regulations for the Safe Transport of Radioactive Material of the International Atomic Energy Agency. (author). 14 refs., 1 fig., tabs

  19. Multidetector row computed tomography may accurately estimate plaque vulnerability. Does MDCT accurately estimate plaque vulnerability? (Pro)

    International Nuclear Information System (INIS)

    Komatsu, Sei; Imai, Atsuko; Kodama, Kazuhisa

    2011-01-01

    Over the past decade, multidetector row computed tomography (MDCT) has become the most reliable and established of the noninvasive examination techniques for detecting coronary heart disease. Now MDCT is chasing intravascular ultrasound (IVUS) in terms of spatial resolution. Among the components of vulnerable plaque, MDCT may detect lipid-rich plaque, the lipid pool, and calcified spots using computed tomography number. Plaque components are detected by MDCT with high accuracy compared with IVUS and angioscopy when assessing vulnerable plaque. The TWINS study and TOGETHAR trial demonstrated that angioscopic loss of yellow color occurred independently of volumetric plaque change by statin therapy. These 2 studies showed that plaque stabilization and regression reflect independent processes mediated by different mechanisms and time course. Noncalcified plaque and/or low-density plaque was found to be the strongest predictor of cardiac events, regardless of lesion severity, and act as a potential marker of plaque vulnerability. MDCT may be an effective tool for early triage of patients with chest pain who have a normal electrocardiogram (ECG) and cardiac enzymes in the emergency department. MDCT has the potential ability to analyze coronary plaque quantitatively and qualitatively if some problems are resolved. MDCT may become an essential tool for detecting and preventing coronary artery disease in the future. (author)

  20. The radiological protection in the radiotherapy

    International Nuclear Information System (INIS)

    Castaneda M, A.; Gonzalez N, A. G.

    2010-09-01

    The cancer incidence in the world has been increased with the course of the time. Fifty percent of the patients receive radiotherapy, as much in the initial treatment, as in the recurrence cases or palliatives. At the moment is considered that in 1998 there were 2,500 teletherapy machines in operation in the countries in development and for the year 2015 will be necessary 10,000. In Mexico the use of these teletherapy units goes back to the year of 1956, when the effort of the Dr. Noriega Limon was consolidated with the installation of the first teletherapy unit with a cobalt 60 source in the National Medical Center of the IMSS. In the same decade the operation began of the Calibration Secondary Center located in the facilities of the General Hospital of Assistance and Health Secretary where a group of seven physicists began in the metrology techniques. Also the national authority in matter of the ionizing radiations use appears and promulgates the first Law in Nuclear Matter. The application has extended in the country, as well as other techniques that have gone incorporating for the cancer treatment. Such as: the brachytherapy, the stereo ataxia and the ophthalmic applicators. In the current application of the radiotherapy several factors are interrelated that have for objective that the dose to the workers and the public is as low as reasonably it can be achieved and that the patient receives the dose prescribed by the medical treatable in the organ or tissue and in the orderly quantity with the minor damage for the healthy tissues. To reach all this, it is necessary to have equipment s, systems, procedures, personal and standards that improve their quality in a gradual but firm way, also the good communication and comprehension among authorities are fundamental for this noble task. (Author)

  1. Sorption of 60 Co in natural zeolite (clinoptilolite)

    International Nuclear Information System (INIS)

    Hernandez B, E.

    1996-01-01

    A Mexican zeolite (clinoptilolite) from Taxco, Guerrero, was partially stabilized with sodium cations. Radioactive Cobalt ( 60 Co) was used to study the Co 2+ sorption in the stabilized zeolite (Na + ). It was found that sorption in general does not favour the diffusion of cobalt between framework, it explains because of it is a natural zeolite and its composition heterogeneous decrease its exchange capacity by the generated competence to the existence other type of exchange ions. The cobalt retention reached the highest level, around 0.408 m eq Co 2+ /g in the Na-Clinoptilolite. The crystallinity of the aluminosilicates was maintained during experiments, it was verified by XRD patterns. (Author)

  2. Early effects of treatment with radium and cobalt-60 gamma radiation on the proportions and absolute counts of T and B lymphocytes in peripheral blood of women with cervical carcinoma

    International Nuclear Information System (INIS)

    Pluzanska, A.; Robak, T.; Kuchowicz, W.; Bartuzel, T.; Studencki, E.; Zadrozna, O.; Mazurowa, A.

    1977-01-01

    In 20 women with cervical carcinoma the T and B lymphocyte counts were determined in peripheral blood. The determinations were carried out before starting treatment and immediately after radium therapy in a mean dose of 6573 mgh and then after full therapeutic dose of cobalt-60 radiation of 4000 R. For identification of T lymphocytes the rosette E test was used and lymphocytes B were identified by means of the EAC rosette test. Presence of immunoglobulins on lymphocytes B was determined as well. In women with cervical carcinoma the total lymphocyte count in 1 mm 3 of blood, the proportions and absolute counts of T and B lymphocytes were not different from those in healthy women. Immediately after radium therapy the lymphocyte count in peripheral blood fell which was due mainly to a fall of the total count and in the proportion of B lymphocytes. The proportion of lymphocytes T was unchanged and their quantitative fall was statistically not significant. After application of the total therapeutic dose of cobalt-60 radiation a further fall of lymphocyte count was observed, due to a fall of the absolute count of T and B lymphocytes. Their proportions were unchanged. (author)

  3. Imaging unstable plaque

    International Nuclear Information System (INIS)

    SRIRANJAN, Rouchelle S.; TARKIN, Jason M.; RUDD, James H.; EVANS, Nicholas R.; CHOWDHURY, Mohammed M.

    2016-01-01

    Recent advances in imaging technology have enabled us to utilise a range of diagnostic approaches to better characterise high-risk atherosclerotic plaque. The aim of this article is to review current and emerging techniques used to detect and quantify unstable plaque in the context of large and small arterial systems and will focus on both invasive and non-invasive imaging techniques. While the diagnosis of clinically relevant atherosclerosis still relies heavily on anatomical assessment of arterial luminal stenosis, evolving multimodal cross-sectional imaging techniques that encompass novel molecular probes can provide added information with regard to plaque composition and overall disease burden. Novel molecular probes currently being developed to track precursors of plaque rupture such as inflammation, micro-calcification, hypoxia and neoangiogenesis are likely to have translational applications beyond diagnostics and have the potential to play a part in quantifying early responses to therapeutic interventions and more accurate cardiovascular risk stratification.

  4. Pilot postal audits in radiotherapy for 60Co in non-reference conditions in Cuba: practical consideration and preliminary results

    International Nuclear Information System (INIS)

    Gutierrez Lores, S.; Walwyn Salas, G.; Alonso Villanueva, G.

    2008-01-01

    Discusses the practical consideration and preliminary results of the Cuban's SSDL in Pilot Postal Audit in Radiotherapy for Co-60 in non-reference conditions under IAEA Coordinated Research Project E2.40.12. A strategy for national TLD audit programmes has been developed by the international Atomic Energy Agency (IAEA). It involves progression through three sequential dosimetry audit steps. The first step audits are for the beam output in reference conditions for photon beams. The second step audits are for the dose in reference and non-reference conditions on the beam axis for photon beams. The third step audits involve measurements of the dose in reference, and non-reference conditions off-axis for open and wedged symmetric and symmetric fields for photon beams. Under coordinated research project E2.40.12 were characterized 100 micro rods. All of these rods were identified individually with a consecutive number made over one of its sides, using a fine tip of graphite. The method used to determinate the individual sensibility of the TL detectors was: irradiating a group of them, with the same history of irradiation and readout. The TLD signal was read using HARSHAW 2000C/B reader. Based on the IAEA standard TLD holder for photon beams, a TLD holder was developed with horizontal arm to enable measurements 5 cm off the central axis. Successful results in two external trial carried out using the IAEA TLD service in the years 2003 - 2004 were obtained. Five 5 facilities were considered to be included in the Pilot Audit Audits in Radiotherapy for Co-60 in non reference conditions (on-axis) in the year 2003, according to recommendation of External Audit Group (EAG). For the year 2004 were considered only 3 facilities in the Pilot Audit Audits in Radiotherapy for Co-60 in non reference conditions (off-axis). Extend the postal dose audits to the rest of the institutions around the country. The participation in these audits promotes a major understanding of the physicists

  5. Helicobacter pylori in dental plaque; is it related to brushing frequency, plaque load and oral health status?

    Science.gov (United States)

    Chaudhry, Saima; Khan, Ayyaz Ali; Butt, Arshad Kamal; Idrees, Muhammad; Izhar, Mateen; Iqbal, Hafiz Aamer

    2011-10-01

    To determine the relation between presence of H. pylori in supra-gingival dental plaque with oral hygiene habits and oral health status of patients suffering from symptomatic dyspepsia. Descriptive study. The Department of Oral Health Sciences, Shaikh Zayed FPGMI, Lahore, from September 2008 to August 2009. One hundred and fifty dyspeptic subjects with dental plaque were enrolled. After recording brushing frequency, oral health status and plaque load, the supra-gingival dental plaque samples were collected by sterile curettes. Helicobacter pylori were detected in dental plaque samples through PCR assay. Presence of H. pylori in dental plaque was found to be 37.5% in the sample. Most of the subjects brushed once daily, had plaque index score of 1 and had fair to poor oral hygiene status. Approximately 35% of the individuals who brushed once or twice a day harbored the bacterium in their dental plaque. There was no difference between bacterial detection rates among different categories of plaque index and oral health status of the study subjects. Presence of H. pylori in dental plaque was found to be associated with neither brushing frequency nor with the plaque load nor with the oral health status of individuals suffering from symptomatic dyspepsia.

  6. Noninvasive characterization of carotid plaque strain.

    Science.gov (United States)

    Khan, Amir A; Sikdar, Siddhartha; Hatsukami, Thomas; Cebral, Juan; Jones, Michael; Huston, John; Howard, George; Lal, Brajesh K

    2017-06-01

    Current risk stratification of internal carotid artery plaques based on diameter-reducing percentage stenosis may be unreliable because ischemic stroke results from plaque disruption with atheroembolization. Biomechanical forces acting on the plaque may render it vulnerable to rupture. The feasibility of ultrasound-based quantification of plaque displacement and strain induced by hemodynamic forces and their relationship to high-risk plaques have not been determined. We studied the feasibility and reliability of carotid plaque strain measurement from clinical B-mode ultrasound images and the relationship of strain to high-risk plaque morphology. We analyzed carotid ultrasound B-mode cine loops obtained in patients with asymptomatic ≥50% stenosis during routine clinical scanning. Optical flow methods were used to quantify plaque motion and shear strain during the cardiac cycle. The magnitude (maximum absolute shear strain rate [MASSR]) and variability (entropy of shear strain rate [ESSR] and variance of shear strain rate [VSSR]) of strain were combined into a composite shear strain index (SSI), which was assessed for interscan repeatability and correlated with plaque echolucency. Nineteen patients (mean age, 70 years) constituting 36 plaques underwent imaging; 37% of patients (n = 7) showed high strain (SSI ≥0.5; MASSR, 2.2; ESSR, 39.7; VSSR, 0.03) in their plaques; the remaining clustered into a low-strain group (SSI routine B-mode imaging using clinical ultrasound machines. High plaque strain correlates with known high-risk echolucent morphology. Strain measurement can complement identification of patients at high risk for plaque disruption and stroke. Copyright © 2017 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.

  7. Study of ozone gas formed in the industrial radiation process with cobalt-60 and its impact on the environment

    International Nuclear Information System (INIS)

    Uzueli, Daniel Henrique

    2013-01-01

    The radiation processing is present in various products such as foods, medical disposable, electrical cables, gems, among others. This process aims to improve the properties, sterilize or sanitize irradiated products. In industrial irradiators facilities, electromagnetic radiation (gamma and X-rays) or electrons before they interact with the products in processing, there are a layer of air. To interact with this air layer, it causes radiolytic effects on the molecules present in the ambient atmosphere, and the main interaction are with the oxygen molecules that have their bonds broken, separating them into two highly reactive atoms that recombine with the other molecule of oxygen to form ozone gas. In this work it was studied the formation, decay and dispersion of ozone in industrial gamma irradiators facilities that use cobalt-60 as a source of radiation. The monitoring of ozone concentration was performed by optical absorption method in a commercial monitor. (author)

  8. Cobalt as a gastric juice volume marker: Comparison of two methods of estimation

    International Nuclear Information System (INIS)

    Gana, T.J.; MacPherson, B.R.; Ng, D.; Koo, J.

    1990-01-01

    We investigated the use of cobalt-EDTA, a novel, nonabsorbable liquid phase marker, in the estimation of secretory volumes during topical misoprostol (synthetic PGE, analog) administration in the canine chambered gastric segment. We compared atomic absorption spectrophotometry (AAS) and instrumental neutron activation analysis (INAA) in the estimation of [Co]. Mucosal bathing solutions containing cobalt-EDTA were instilled into and recovered from the chamber by gravity every 15-min period as follows: (i) basal--60 min; (ii) misoprostol periods--150 min (plus 0.1-, 1-, 10-, 100-, and 1000-micrograms doses of misoprostol for two periods per dose). The recovered solutions were analyzed for [Co] by AAS and INAA. Total cobalt recovery by AAS after chamber washout was 102.97 +/- 0.98%. Mean +/- SE volumes (12.14 +/- 0.33 and 13.24 +/- 0.60 ml/15 min) obtained respectively from AAS and INAA were significantly higher (P less than 0.001) than the recovered mean volumes (10.51 +/- 0.17 ml/15 min). The percentage error in volume collection increased (range: 9.3-52.7%) with the volume of secretion. Values of [Co] obtained by the two techniques were comparable and not significantly different from each other (P greater than 0.05). INAA-estimated mean +/- SE [Co] showed consistently higher coefficients of variation. Spectra obtained for all samples during INAA measurements showed significant Compton background activity from 24Na and 38Cl. Cobalt-EDTA did not grossly or histologically damage the gastric mucosa. We conclude that cobalt is not adsorbed, absorbed, or metabolized, and is a suitable and reliable volume marker in this model

  9. External cobalt 60 irradiation alone for stage IIB carcinoma of the uterine cervix

    International Nuclear Information System (INIS)

    Lei, Z.Z.; He, F.Z.

    1989-01-01

    From 1964 to 1980, 97 patients with Stage IIb carcinoma of cervix uteri were treated by external 60Co irradiation alone. Of these 97 patients, 94 (96.9%) had squamous cell carcinoma. The parametrial extension of the lesion almost reached the pelvic wall in 73.2% and vaginal extension reached to the upper half of vaginal in 24.7% of the patients. A tumor dose of 60 Gy was given to the whole pelvis by a four field technic (opposing parallel AP and lateral portals) in 6-8 weeks. A booster dose of 10 Gy was delivered to the cervix by a pair of reduced opposing parallel AP portals or a perineal portal in a week. The doses delivered were equivalent to the Time-Dose-Fractionation (TDF) value of 110-130 at the center of pelvis and 90-110 in the whole pelvis. The 5-year survival rate for all 97 patients was 56.7%. It was 59.8% when those who died of other diseases were excluded. The prognosis of patients without residual tumor on the cervix and/or vagina was better than that with residual tumor (p less than 0.01). Thirty-seven patients died of cancer (23 died of recurrence, 8 of distant metastases, 2 of both, and 4 were lost before the fifth year). Of these 37 patients, 97.3% died within 3 years after initial treatment. During the radiation treatment, reactions were moderate. Late complications included 19 (19.6%) with mild cystitis and 16 (16.5%) with mild proctitis, 2 (2.7%) developed recto-vaginal fistula. These results were slightly poorer than those using intracavitary and external irradiation or the combination of preoperative irradiation plus surgery. Yet, for patients with extensions nearing the pelvic wall or with contra-indications to surgery or intracavitary radiotherapy, external irradiation alone is still of value

  10. Passivation and corrosion behaviours of cobalt and cobalt-chromium-molybdenum alloy

    International Nuclear Information System (INIS)

    Metikos-Hukovic, M.; Babic, R.

    2007-01-01

    Passivation and corrosion behaviour of the cobalt and cobalt-base alloy Co30Cr6Mo was studied in a simulated physiological solution containing chloride and bicarbonate ions and with pH of 6.8. The oxido-reduction processes included solid state transformations occurring at the cobalt/electrolyte interface are interpreted using theories of surface electrochemistry. The dissolution of cobalt is significantly suppressed by alloying it with chromium and molybdenum, since the alloy exhibited 'chromium like' passivity. The structural and protective properties of passive oxide films formed spontaneously at the open circuit potential or during the anodic polarization were studied using electrochemical impedance spectroscopy in the wide frequency range

  11. Results of definitive radiotherapy in T1 and T2 glottic carcinoma: Institute of Rotary Cancer Hospital experience

    International Nuclear Information System (INIS)

    Mohanti, B.K.; Rath, G.K.; Tanwar, R.K.; Lal, P.; Biswal, B.M.; Tandon, D.A.; Bahadur, S.

    1996-01-01

    Early glottic carcinomas (T1 and T2) constitute only 2% of all laryngeal cancers in our data. Seventy patients were seen between 1985 and 1992. All patients were treated by cobalt-60 small field radiotherapy using a beam directed shell. The total dose delivered was 60-65Gy in 31 patients and 66-70Gy in 39 patients. The follow-up period ranged from 5 to 126 months, with a mean follow up of 37 months overall and 55 months in the surgical salvage group. Radiation therapy controlled disease in 71% (50 of 70) of patients overall; 75% with T1 and 67% with T2 lesions. Total laryngectomy as salvage surgery was performed in 70% (14 of 20) of patients whose disease recurred. Ultimate control including surgical salvage occurred in 64 (91 %) of 70 patients in the present study. The actuarial 5 year survival was 83 and 80% in T1 and T2 tumours, respectively (statistically insignificant). This report supports the policy of definitive irradiation, reserving surgical salvage for radiation failures in early laryngeal cancers. 17 refs., 2 tabs

  12. Plaque control and oral hygiene methods

    LENUS (Irish Health Repository)

    Harrison, Peter

    2017-06-01

    The experimental gingivitis study of Löe et al.1 demonstrated a cause and effect relationship between plaque accumulation and gingival inflammation, and helped to establish plaque\\/biofilm as the primary risk factor for gingivitis. When healthy individuals withdrew oral hygiene efforts, gingival inflammation ensued within 21 days in all subjects. Once effective plaque removal was recommenced, clinical gingival health was quickly re-established – indicating that plaque-associated inflammation is modifiable by plaque control. As current consensus confirms that gingivitis and periodontitis may be viewed as a continuum of disease,2 the rationale for achieving effective plaque control is clear.

  13. Resolving the brachytherapy challenges with government funded hospital.

    Science.gov (United States)

    Nikam, D S; Jagtap, A S; Vinothraj, R

    2016-01-01

    The objective of this study is to rationalize the feasibility and cost-effectiveness of high dose rate (HDR) cobalt 60 (Co-60) source versus 192-Iridium (192-Ir) source brachytherapy in government funded hospitals and treatment interruption gap because of exchange of sources. A retrospective study of gynecological cancer patients, treated by radiotherapy with curative intent between April 2005 and September 2012 was conducted. We analyzed the total number of patients treated for external beam radiotherapy (EBRT) and brachytherapy (Intracavitary brachytherapy or cylindrical vaginal source). The dates for 192-Ir sources installation and the last date and first date of brachytherapy procedure before and after source installation respectively were also analyzed and calculated the gap in days for brachytherapy interruptions. The study was analyzed the records of 2005 to September 2012 year where eight 192-Ir sources were installed. The mean gap between treatment interruptions was 123.12 days (range 1-647 days). The Institutional incidence of gynecological cancer where radiotherapy was treatment modality (except ovary) is 34.9 percent. Around 52.25 percent of patients who received EBRT at this institute were referred to outside hospital for brachytherapy because of unavailability of Iridium source. The cost for 5 year duration for single cobalt source is approximately 20-22 lakhs while for 15 Iridium sources is approximately 52-53 lakhs. The combined HDR Co-60 brachytherapy and EBRT provide a useful modality in the treatment of gynecological cancer where radiotherapy is indicated, the treatment interruption because of source exchange is longer and can be minimized by using cobalt source as it is cost-effective and has 5 year working life. Thus, Co-60 source for brachytherapy is a feasible option for government funded hospitals in developing countries.

  14. Early versus delayed postoperative radiotherapy for treatment of low-grade gliomas

    Science.gov (United States)

    Sarmiento, J Manuel; Venteicher, Andrew S; Patil, Chirag G

    2015-01-01

    Background In most people with low-grade gliomas (LGG), the primary treatment regimen remains a combination of surgery followed by postoperative radiotherapy. However, the optimal timing of radiotherapy is controversial. It is unclear whether to use radiotherapy in the early postoperative period, or whether radiotherapy should be delayed until tumour progression occurs. Objectives To assess the effects of early postoperative radiotherapy versus radiotherapy delayed until tumour progression for low-grade intracranial gliomas in people who had initial biopsy or surgical resection. Search methods We searched up to September 2014 the following electronic databases: the Cochrane Register of Controlled Trials (CENTRAL, Issue 8, 2014), MEDLINE (1948 to Aug week 3, 2014), and EMBASE (1980 to Aug week 3, 2014) to identify trials for inclusion in this Cochrane review. Selection criteria We included randomised controlled trials (RCTs) that compared early versus delayed radiotherapy following biopsy or surgical resection for the treatment of people with newly diagnosed intracranial LGG (astrocytoma, oligodendroglioma, mixed oligoastrocytoma, astroblastoma, xanthoastrocytoma, or ganglioglioma). Radiotherapy may include conformal external beam radiotherapy (EBRT) with linear accelerator or cobalt-60 sources, intensity-modulated radiotherapy (IMRT), or stereotactic radiosurgery (SRS). Data collection and analysis Three review authors independently assessed the trials for inclusion and risk of bias, and extracted study data. We resolved any differences between review authors by discussion. Adverse effects were also extracted from the study report. We performed meta-analyses using a random-effects model with inverse variance weighting. Main results We included one large, multi-institutional, prospective RCT, involving 311 participants; the risk of bias in this study was unclear. This study found that early postoperative radiotherapy is associated with an increase in time to

  15. Consumption of baked nuts or seeds reduces dental plaque acidogenicity after sucrose challenge.

    Science.gov (United States)

    Wang, Xiaoling; Cheng, Chuoyue; Ge, Chunling; Wang, Bing; Gan, Ye-Hua

    2016-06-01

    To assess the acidogenic potential of eight different types of baked nuts or seeds eaten alone and after a sucrose challenge using in-dwelling electrode telemetry. Six participants wearing a mandibular partial prosthesis incorporated with a miniature glass pH electrode were enrolled. The plaque pH was measured after 5 or 6 days of plaque accumulation. To establish a control, the subjects were instructed to rinse with sucrose, without any subsequent treatment, at the first visit. At each subsequent test visit, the subjects were asked to chew sugar free xylitol gum or consume 10 g of baked (180 degrees C, 5 minutes) peanuts, walnuts, pistachios, cashews, almonds, sunflower seeds, pumpkin seeds, or watermelon seeds alone and 10 minutes after a sucrose rinse. The minimum plaque pH value and area of plaque pH curve under 5.7 (AUC5.7) during and after nut/seed consumption or gum chewing alone, the plaque pH value at 10 minutes after the sucrose rinse, the time required for the pH to return to >5.7 and AUC5.7 after the sucrose rinse with or without nut/seed consumption or gum chewing were calculated from the telemetric curves. The sucrose rinse induced a rapid decrease in the plaque pH to 4.32 +/- 0.17 at 10 minutes; this value remained below 5.7 for the measurement period. The AUC5.7 values were 34.58 +/- 7.27 and 63.55 +/- 15.17 for 40 and 60 minutes after the sucrose challenge, respectively. With the exception of cashews and pumpkin seeds (minimum pH, 5.42 and 5.63 respectively), the nuts or seeds did not decrease the plaque pH to below 5.7 when consumed alone, with the AUC5.7 values during and after consumption (total 40 minutes) ranging from 0.24 to 2.5 (8.44 for cashews), which were significantly lower than those after the sucrose challenge. Furthermore, nut/seed consumption or gum chewing after the sucrose challenge significantly reversed the sucrose-induced decrease in the plaque pH, and the time required for the pH to return to >5.7 and the AUC5.7 values for 60

  16. Influence of the protective cream and synthetic zeolites on the transfer of the 60Co across the skin of rat

    International Nuclear Information System (INIS)

    Kassai, Z.; Koprda, V.; Harangozo, M.; Palinkasova, A.; Bauerova, K.

    2000-01-01

    In this paper the influence of protection cream and synthetic zeolite on the transfer of the cobalt-60 across the skin of rat was examined. Influence of different methods of cream application on kinetics of cobalt-60 permeation is described

  17. Standardization of radiotherapy for less radio-curable malignancies

    Energy Technology Data Exchange (ETDEWEB)

    Asakawa, Hiroshi; Yamada, Shogo [Miyagi Prefectural Adult Disease Center, Natori (Japan)

    1982-09-01

    Standardization of radiotherapy for esophageal and gastric cancer was discussed, as the representatives of less radio-curable malignancies. In esophageal carcinoma, it was concluded that radiotherapy should be valuable as a curative procedure. The curative indications for radiotherapy should be the cases of T1-2 N0-1M0 with tumorous or some ulcerous types of carcinoma. Target volume should be defined to the small region, including the primary tumor and the regional lymph node (N1). The dose of 60 to 70 Gy should be optimal and given with the homogeneity of 90%. In gastric carcinoma, it seemed that radiotherapy was a palliative treatment for inoperable carcinoma and should be indicated for the cases of T1-3NxM0 with radio-responsive tumor. Target volume should be localized to the primary lesion and the dose of 50 to 60 Gy should be given as the maximum. Split course radiotherapy was recommended to avoid the serious complications.

  18. Denture plaque--past and recent concerns.

    Science.gov (United States)

    Nikawa, H; Hamada, T; Yamamoto, T

    1998-05-01

    This paper critically reviews the history of denture plaque and identifies some concerns with the presence of Candida in the mouth. This review covers literature sources related to Candida albicans and its relationship to denture plaque. The articles selected for this review are from referred journals and describe C. albicans and its relationship to oral, gastrointestinal and pleuropulmonary infections. The relationship to caries, root caries and periodontal disease is also covered. Denture plaque containing Candida could cause not only oral candidiasis, like oral thrush or denture-induced stomatitis, but also caries, root caries and periodontitis of abutment teeth. However, there is only limited experimental evidence or information available on the cariogenicity of Candida. The continuous swallowing or aspiration of micro-organisms from denture plaque exposes patients, particularly the immunocompromised host or medicated elderly, to the risks of unexpected infections. The term, 'denture plaque' has been used throughout the review. However, the term 'plaque on denture' should be used because the microbial flora and its pathogenicity of denture plaque resembles those of plaque formed on the tooth surface, so called dental plaque. In addition, the term 'denture related stomatitis' would be preferable to 'denture induced stomatitis', since the inflammation of (palatal) mucosa is not induced by the denture, but by wearing the denture or by plaque on the denture.

  19. Elicitation threshold of cobalt chloride

    DEFF Research Database (Denmark)

    Fischer, Louise A; Johansen, Jeanne D; Voelund, Aage

    2016-01-01

    : On the basis of five included studies, the ED10 values of aqueous cobalt chloride ranged between 0.0663 and 1.95 µg cobalt/cm(2), corresponding to 30.8-259 ppm. CONCLUSIONS: Our analysis provides an overview of the doses of cobalt that are required to elicit allergic cobalt contactdermatitis in sensitized...

  20. Late effects of protracted whole-body irradiation of beagles by cobalt-60 gamma rays

    International Nuclear Information System (INIS)

    Fritz, T.E.; Seed, T.M.; Tolle, D.V.; Lombard, L.S.

    1986-01-01

    So that a stronger basis for extrapolation of low-level radiation effects to man can be provided, existing data from small laboratory animals are being supplemented by studies in a longer lived animal, the dog. Beagle dogs are exposed to continuous cobalt-60 irradiation either throughout life or until predetermined total doses are accumulated. The radiation-specific excess-mortality rate and associated causes of death will be related to both dose rate and total dose. The ongoing studies also emphasize the pathogenesis of myelogenous leukemia. At dose rates of 3.75 to 26.25 rads/day, given continuously, responses were consistent, highly dose-rate dependent, and limited primarily to the hematopoietic system. At rates as low as 0.3 rad/day, the hematopoietic system is still the limiting factor for survival, but below 3.75 rads/day present evidence suggests that the responses are independent of dose rate. Longitudinal studies of peripheral blood and bone marrow detected four preclinical phases of myelogenous leukemia. These phases were characterized by standard hematologic end points, ultrastructural features, in vitro cloning assays, and the acute radiation sensitivity of stem cells. Results suggest that an induced error-prone repair mechanism is the basis for the onset of radiation-induced myelogenous leukemia. Interim data from dogs given terminated exposures suggest that the types of tumors and times to death are different from controls but the numbers of tumors are not yet greater than in controls. 26 refs., 12 figs., 5 tabs

  1. Salivary flow rate and pH after radiotherapy of the head and neck region; Velocidade do fluxo e pH salivar apos radioterapia da regiao de cabeca e pescoco

    Energy Technology Data Exchange (ETDEWEB)

    Lima, Antonio Adilson Soares de [Pontificia Universidade Catolica do Parana, Curitiba, PR (Brazil). Curso de Odontologia; Figueiredo, Maria Antonia Zancanaro de [Pontificia Universidade Catolica do Rio Grande do Sul, Porto Alegre, RS (Brazil). Curso de Odontologia; Krapf, Stella Maria Rigo; Souza, Fabiany Rodrigues de [Pontificia Universidade Catolica do Rio Grande do Sul, Porto Alegre, RS (Brazil). Hospital Sao Lucas]. E-mail: adillima@terra.com.br

    2004-07-01

    The most common sequelae in head and neck cancer patients submitted to radiotherapy (60Cobalt) is postirradiation hypo salivation. This leads to a change in oral physiology, and, as a consequence, the irradiated individual is susceptible to infections and caries lesions. The aim of this study was to evaluate the behaviour of stimulated whole saliva flow rate (SWSFR) during and after radiotherapy treatment for head and neck cancer by lateral opposed fields. Six samples of mechanically stimulated whole saliva were collected of each individual and evaluated by gravimetric method.The first sample was collected before radiotherapy; the second one after 1500 cGy dose; the third one after the last dose of treatment and the remainder samples in intervals of subsequent two months up to six months after the end of treatment. The SWSFR decreased in 50% after a dose of 1500 cGy (1/4 of received treatment). After radiation therapy, the SWSFR was 0,33 ml/min and after six months was 0,20 ml/min. These values represented, respectively, a decreasing in 64% and 78% of initial values (ANOVA, Tukey's Test p<0.05).Based in these results, the authors concluded radiotherapy when applied in malign neoplasms of the head and neck region by lateral opposed fields was able to decrease significantly salivary flow rate. Intensive preventive dental care during and after radiotherapy seems to be an useful tool to avoid radiation caries and their complications. (author)

  2. Effectiveness of herbal and nonherbal fluoridated toothpaste on plaque and gingivitis: A randomized controlled trial

    Directory of Open Access Journals (Sweden)

    Roopali Gupta

    2015-01-01

    Full Text Available Introduction: Dental plaque is a well-known etiologic factor for gingivitis. Ayurvedic drugs have been used since ancient times to treat diseases including periodontal diseases. Toothpastes made from herbal medicines are used in periodontal therapy to control bleeding and reduce inflammation. Aim: To compare the effectiveness of herbal and nonherbal fluoridated toothpaste on plaque and gingivitis among residents of ladies hostel in Mathura City. Materials and Methods: A randomized controlled clinical trial was carried out on 60 participants aged 18-30 years residing in a ladies hostel of Mathura City. The 60 participants were randomly allocated into two groups: Group-I: Experimental group using herbal toothpaste, Group-II: Control group using fluoridated toothpaste. The subjects were asked to brush twice daily with the assigned dentifrice using standardized brushing technique for 46 days. The plaque and gingival indices were recorded according to Silness and Loe (1964 and Loe and Silness (1963, respectively. These parameters were assessed at baseline, 3 weeks, and 6 weeks. Data were analyzed by Student paired t-test and unpaired t-test using Statistical Package for the Social Sciences version 21 manufactured by IBM Corporation - Armonk, New York, US. Results: Baseline plaque and gingival scores were found 1.02 ± 0.02 and 0.88 ± 0.06 for the experimental group and 1.02 ± 0.03 and 0.81 ± 0.08 for control group, respectively. After 6 weeks plaque and gingival scores were found 0.77 ± 0.07 and 0.72 ± 0.08 for experimental group and 0.78 ± 0.07 and 0.73 ± 0.11 for control group, respectively. Statistically significant differences were obtained before and after intervention in both groups (P ≤ 0.05. Conclusion: The herbal toothpaste was as effective as the conventionally formulated fluoride dentifrice in controlling plaque and gingivitis.

  3. Skin response to cobalt 60 irradiation and the consequences for matching the color of facial prostheses

    International Nuclear Information System (INIS)

    van Oort, R.P.; Vermey, J.; Ten Bosch, J.J.

    1984-01-01

    A radiotherapy treatment ( 60 Co) of cancer in the head and neck region causes side effects in the skin that postpone the facial prosthetic treatment. The increasing and fading erythema and pigmentation of the skin was investigated with the use of a subtractive colorimeter. This method was verified with photographs scored according to the Oxford scoring system. Fourteen patients were investigated during a period of 24 weeks. The mean colorimetric skin response showed a peak 6 weeks after the onset of irradiation. Six to 7 weeks later, there was no significant difference between the skin color before and after irradiation. At this time the dry desquamation of the skin is healed. From this viewpoint, the color matching procedure for a facial prosthesis may start not earlier than 15 weeks from the onset of irradiation. If a nonirradiated control field in the facial region is present, a color match for the facial prosthesis can be started just after the irradiation period

  4. A comparison between plaque-based and vessel-based measurement for plaque component using volumetric intravascular ultrasound radiofrequency data analysis.

    Science.gov (United States)

    Shin, Eun-Seok; Garcia-Garcia, Hector M; Garg, Scot; Serruys, Patrick W

    2011-04-01

    Although percent plaque components on plaque-based measurement have been used traditionally in previous studies, the impact of vessel-based measurement for percent plaque components have yet to be studied. The purpose of this study was therefore to correlate percent plaque components derived by plaque- and vessel-based measurement using intravascular ultrasound virtual histology (IVUS-VH). The patient cohort comprised of 206 patients with de novo coronary artery lesions who were imaged with IVUS-VH. Age ranged from 35 to 88 years old, and 124 patients were male. Whole pullback analysis was used to calculate plaque volume, vessel volume, and absolute and percent volumes of fibrous, fibrofatty, necrotic core, and dense calcium. The plaque and vessel volumes were well correlated (r = 0.893, P measurement was also highly correlated with vessel-based measurement. Therefore, the percent plaque component volume calculated by vessel volume could be used instead of the conventional percent plaque component volume calculated by plaque volume.

  5. Detection and segmentation of virus plaque using HOG and SVM: toward automatic plaque assay.

    Science.gov (United States)

    Mao, Yihao; Liu, Hong; Ye, Rong; Shi, Yonghong; Song, Zhijian

    2014-01-01

    Plaque assaying, measurement of the number, diameter, and area of plaques in a Petri dish image, is a standard procedure gauging the concentration of phage in biology. This paper presented a novel and effective method for implementing automatic plaque assaying. The method was mainly comprised of the following steps: In the training stage, after pre-processing the images for noise suppression, an initial training set was readied by sampling positive (with a plaque at the center) and negative (plaque-free) patches from the training images, and extracting the HOG features from each patch. The linear SVM classifier was trained in a self-learnt supervised learning strategy to avoid possible missing detection. Specifically, the training set which contained positive and negative patches sampled manually from training images was used to train the preliminary classifier which exhaustively searched the training images to predict the label for the unlabeled patches. The mislabeled patches were evaluated by experts and relabeled. And all the newly labeled patches and their corresponding HOG features were added to the initial training set to train the final classifier. In the testing stage, a sliding-window technique was first applied to the unseen image for obtaining HOG features, which were inputted into the classifier to predict whether the patch was positive. Second, a locally adaptive Otsu method was performed on the positive patches to segment the plaques. Finally, after removing the outliers, the parameters of the plaques were measured in the segmented plaques. The experimental results demonstrated that the accuracy of the proposed method was similar to the one measured manually by experts, but it took less than 30 seconds.

  6. Dependence of some transmission factors on field size and treatment depth in external beam radiation therapy (EBRT) using the theratron equinox 100 cobalt 60 machine

    International Nuclear Information System (INIS)

    Odonkor, P.

    2015-07-01

    The use of beam modifiers in today’s radiotherapy is very important as it attenuates the beam and reduces the dose to the patient; therefore the need to know the amount of attenuation (in terms of a transmission factor) they provide during treatment. The purpose of this research work is to evaluate the variation (or dependence) of the transmission factors (TFs) of block tray and physical wedges (of different angles) as a function of treatment depth and field size using both iso-centric setups, SAD and SSD; and thus compare the results from the two setup techniques. Wedge and tray TF measurements were performed in a full scatter, large water phantom using a 0.04cc ionization chamber and an average photon energy of 1.25MV from a cobalt-60 unit at an SAD/SSD of 100cm at various depths and field sizes with gantry and collimator angles fixed at 0°. From the measurements carried out, the wedge TF of the 15°, 30°, 45°, and 60°, wedges were found to be 0.775±0.005, 0.650±0.010, 0.505±0.015, and 0.280±0.015 respectively; and the tray TF was found to be 0.960±0.003. Also, the results obtained showed that both the wedge TF and the tray TF has a strong linear dependence on treatment depth; however, the variation of the 15°, wedge TF and the tray TF with depth is less significant (less than 2%). Maximum percentage variation for the 15°, wedge for the SAD setup was 1.1% and 1.59% for the SSD setup; and that for the tray was 0.60% for the SAD setup and 0.12% for the SSD setup. Also, the variation of the 15°, 30°, and 45°, wedge TF with field size was less significant (less than 2%); and a weaker dependence was observed with field size as compared to the treatment depth. However, the 60°, wedge showed a significant variation (maximum of 2.22% and 2.88% for the SAD and SSD setups respectively) as an increase in field size was accompanied by an increase in its wedge TF. Also though the tray TF graphically showed a strong linear dependence on field size the

  7. Current status of vulnerable plaque detection.

    LENUS (Irish Health Repository)

    Sharif, Faisal

    2012-02-01

    Critical coronary stenoses have been shown to contribute to only a minority of acute coronary syndromes (ACS) and sudden cardiac death. Autopsy studies have identified a subgroup of high-risk patients with disrupted vulnerable plaque and modest stenosis. Consequently, a clinical need exists to develop methods to identify these plaques prospectively before disruption and clinical expression of disease. Recent advances in invasive and noninvasive imaging techniques have shown the potential to identify these high-risk plaques. The anatomical characteristics of the vulnerable plaque such as thin cap fibroatheroma and lipid pool can be identified with angioscopy, high frequency intravascular ultrasound, intravascular MRI, and optical coherence tomography. Efforts have also been made to recognize active inflammation in high-risk plaques using intravascular thermography. Plaque chemical composition by measuring electromagnetic radiation using spectroscopy is also an emerging technology to detect vulnerable plaques. Noninvasive imaging with MRI, CT, and PET also holds the potential to differentiate between low and high-risk plaques. However, at present none of these imaging modalities are able to detect vulnerable plaque neither has been shown to definitively predict outcome. Nevertheless in contrast, there has been a parallel development in the physiological assessment of advanced atherosclerotic coronary artery disease. Thus recent trials using fractional flow reserve in patients with modest non flow-limiting stenoses have shown that deferral of PCI with optimal medical therapy in these patients is superior to coronary intervention. Further trials are needed to provide more information regarding the natural history of high-risk but non flow-limiting plaque to establish patient-specific targeted therapy and to refine plaque stabilizing strategies in the future.

  8. Gene expression and 18FDG uptake in atherosclerotic carotid plaques

    DEFF Research Database (Denmark)

    Pedersen, Sune Folke; Graebe, Martin; Fisker Hag, Anne Mette

    2010-01-01

    ) and an additional ipsilateral internal carotid artery stenosis of greater than 60% were recruited. FDG uptake in the carotids was determined by PET/computed tomography and expressed as mean and maximal standardized uptake values (SUVmean and SUVmax). The atherosclerotic plaques were subsequently recovered...... by carotid endarterectomy. The gene expression of markers of vulnerability - CD68, IL-18, matrix metalloproteinase 9, cathepsin K, GLUT-1, and hexokinase type II (HK2) - were measured in plaques by quantitative PCR. RESULTS: In a multivariate linear regression model, GLUT-1, CD68, cathepsin K, and HK2 gene...... expression remained in the final model as predictive variables of FDG accumulation calculated as SUVmean (R=0.26, PK, and HK2 gene expression as independent predictive variables of FDG accumulation calculated...

  9. Encrusted cystitis after definitive radiotherapy for cervical cancer: a case report

    Directory of Open Access Journals (Sweden)

    Elisabetta Perrucci

    2016-10-01

    Full Text Available Purpose : Encrusted cystitis is a rare chronic inflammatory disease characterized by calcified plaques of the bladder, previously altered by varies conditions as urological procedures, caused by urea-splitting bacteria. Only one case has been reported on encrusted cystitis occurring after surgery and radiation therapy for a pelvic neoplasm. We report on encrusted cystitis occurred after definitive radiotherapy for bulky uterine cervix cancer, and examine the doses to the bladder wall and the procedure of radiation treatment performed as a possible cause of the onset of the disease. Case presentation : A 52-year-old female developed encrusted cystitis, caused by Corynebacterium spp., after 14 months from definitive chemo-radiotherapy and 2/D brachytherapy treatment for FIGO stage IB2 uterine cervix cancer. For pelvic radiotherapy, the mean bladder dose was 48.47 Gy (range 31.20–51.91; maximal bladder point doses at each brachytherapy insertions were 7.62 Gy, 4.94 Gy and 6.27 Gy at first, second, and third fraction, respectively. Total biological effective dose (BED at bladder point was 140.05 Gy3. The patient was administered antibiotic therapy with linezolid and urine acidification with vitamin C; dietary norms were also suggested. After therapy, complete remission of symptoms and radiological findings were achieved, and the planned surgery for removing the calcified plaques was not completed. After 5 years from the cervical cancer diagnosis, the patient was disease-free without urinary symptoms. Conclusions : The high doses administered to the bladder wall and the repeated catheterizations performed at each brachytherapy insertions may have favored the infection and promoted the occurrence of the encrusted cystitis.

  10. Iterative image reconstruction algorithms in coronary CT angiography improve the detection of lipid-core plaque - a comparison with histology

    Energy Technology Data Exchange (ETDEWEB)

    Puchner, Stefan B. [Massachusetts General Hospital, Harvard Medical School, Cardiac MR PET CT Program, Department of Radiology, Boston, MA (United States); Medical University of Vienna, Department of Biomedical Imaging and Image-Guided Therapy, Vienna (Austria); Ferencik, Maros [Massachusetts General Hospital, Harvard Medical School, Cardiac MR PET CT Program, Department of Radiology, Boston, MA (United States); Harvard Medical School, Division of Cardiology, Massachusetts General Hospital, Boston, MA (United States); Maurovich-Horvat, Pal [Massachusetts General Hospital, Harvard Medical School, Cardiac MR PET CT Program, Department of Radiology, Boston, MA (United States); Semmelweis University, MTA-SE Lenduelet Cardiovascular Imaging Research Group, Heart and Vascular Center, Budapest (Hungary); Nakano, Masataka; Otsuka, Fumiyuki; Virmani, Renu [CV Path Institute Inc., Gaithersburg, MD (United States); Kauczor, Hans-Ulrich [University Hospital Heidelberg, Ruprecht-Karls-University of Heidelberg, Department of Diagnostic and Interventional Radiology, Heidelberg (Germany); Hoffmann, Udo [Massachusetts General Hospital, Harvard Medical School, Cardiac MR PET CT Program, Department of Radiology, Boston, MA (United States); Schlett, Christopher L. [Massachusetts General Hospital, Harvard Medical School, Cardiac MR PET CT Program, Department of Radiology, Boston, MA (United States); University Hospital Heidelberg, Ruprecht-Karls-University of Heidelberg, Department of Diagnostic and Interventional Radiology, Heidelberg (Germany)

    2015-01-15

    To evaluate whether iterative reconstruction algorithms improve the diagnostic accuracy of coronary CT angiography (CCTA) for detection of lipid-core plaque (LCP) compared to histology. CCTA and histological data were acquired from three ex vivo hearts. CCTA images were reconstructed using filtered back projection (FBP), adaptive-statistical (ASIR) and model-based (MBIR) iterative algorithms. Vessel cross-sections were co-registered between FBP/ASIR/MBIR and histology. Plaque area <60 HU was semiautomatically quantified in CCTA. LCP was defined by histology as fibroatheroma with a large lipid/necrotic core. Area under the curve (AUC) was derived from logistic regression analysis as a measure of diagnostic accuracy. Overall, 173 CCTA triplets (FBP/ASIR/MBIR) were co-registered with histology. LCP was present in 26 cross-sections. Average measured plaque area <60 HU was significantly larger in LCP compared to non-LCP cross-sections (mm{sup 2}: 5.78 ± 2.29 vs. 3.39 ± 1.68 FBP; 5.92 ± 1.87 vs. 3.43 ± 1.62 ASIR; 6.40 ± 1.55 vs. 3.49 ± 1.50 MBIR; all p < 0.0001). AUC for detecting LCP was 0.803/0.850/0.903 for FBP/ASIR/MBIR and was significantly higher for MBIR compared to FBP (p = 0.01). MBIR increased sensitivity for detection of LCP by CCTA. Plaque area <60 HU in CCTA was associated with LCP in histology regardless of the reconstruction algorithm. However, MBIR demonstrated higher accuracy for detecting LCP, which may improve vulnerable plaque detection by CCTA. (orig.)

  11. Topographic association of angioscopic yellow plaques with coronary atherosclerotic plaque: assessment with quantitative colorimetry in human coronary artery autopsy specimens.

    Science.gov (United States)

    Ishibashi, Fumiyuki; Lisauskas, Jennifer B; Kawamura, Akio; Waxman, Sergio

    2008-01-01

    Yellow plaques seen during coronary angioscopy are thought to be the surrogates for superficial intimal lipids in coronary plaque. Given diffuse and heterogeneous nature of atherosclerosis, yellow plaques in coronaries may be seen as several yellow spots on diffuse coronary plaque. We examined the topographic association of yellow plaques with coronary plaque. In 40 non-severely stenotic ex-vivo coronary segments (average length: 52.2 +/- 3.1 mm), yellow plaques were examined by angioscopy with quantitative colorimetry. The segments were cut perpendicular to the long axis of the vessel at 2 mm intervals, and 1045 slides with 5 microm thick tissue for whole segments were prepared. To construct the plaque surface, each tissue slice was considered to be representative of the adjacent 2 mm. The circumference of the lumen and the lumen border of plaque were measured in each slide, and the plaque surface region was constructed. Coronary plaque was in 37 (93%) of 40 segments, and consisted of a single mass [39.9 +/- 3.9 (0-100) mm, 311.3 +/- 47.4 (0.0-1336.2) mm2]. In 30 (75%) segments, multiple (2-9) yellow plaques were detected on a mass of coronary plaque. The number of yellow plaques correlated positively with coronary plaque surface area (r = 0.77, P colorimetry, some of them are associated with lipid cores underneath thin fibrous caps, may be used to assess the extent of coronary plaque. Further research using angioscopy could be of value to study the association of high-risk coronaries with acute coronary syndromes.

  12. Evaluation of the radiotherapy combined with surgery for extrahepatic bile duct cancer and pancreatoduodenal cancer

    International Nuclear Information System (INIS)

    Takezawa, Jiro

    1984-01-01

    Curative resection of extrahepatic bile duct cancer and pancreatoduodenal cancer is very difficult, and its long term result is pessimistic. Twenty patients with bile duct cancer (12 resected and 8 non-resected) and 23 patients with pancreatoduodenal cancer (10 resected and 13 non-resected) were treated with extracorporeal Cobalt-60 irradiation following the surgery. The just opposed anterior and posterior ports were used with the field size ranging from 6 x 6 cm to 13 x 14 cm. The delivered doses ranged from 46 to 60 Gy (70 - 108TDF) for bile duct cancer, and from 18 to 66 Gy (28 - 104TDF) for pancreatoduodenal cancer. On one of resected and 4 of non-resected patients with pancreatoduodenal cancer, the therapeutic schedule could not be pursued completely because of decreased leucocytes and emaciation. The postoperative survivals were compared between the cases with and without adjunctive radiotherapy. The longest and mean survivals of the patients with resected bile duct cancer were 41 mos. and 20 mos. respectively, in the irradiated v.s. 21 mos. and 14 mos. in the non-irradiated group. The mean survival of the patients without resection of bile duct cancer was 15 mos. in the irradiated v.s. 6 mos. in the non-irradiated group; one resected case has survived more than 61 mos. after radiotherapy and is still alive. The mean survival after resection of pancreatoduodenal cancer was 16 mos. in the irradiated v.s. 11 mos. in non-irradiated group, and 3 in the former are still alive, one having survived the longest 50 mos. The longest and mean survival of the patients without resection of pancreatoduodenal cancer were 22 mos. and 8 mos. respectively v.s. 7 mos. and 4 mos. of the non-irradiated patients. Advantageous effects of radiotherapy combined with surgery for bile duct cancer and pancreatoduodenal cancer were observed throughout this clinical study. (author)

  13. The effects of zinc on cobalt deposition in PWRs: summary report

    International Nuclear Information System (INIS)

    Bennet, Peter

    1996-01-01

    An experiment has been performed in a PWR loop of the Halden reactor to investigate the effects of the addition of 50 ppb zinc to the coolant on the incorporation of cobalt into the oxide films on primary circuit constructional materials. This report summarises the results from the three phases of the test. It was shown that zinc addition inhibits the corrosion of both new metal surfaces and surfaces with well-established oxides; this results in thinner oxide layers and reduced incorporation of cobalt into the oxide. Generally, there were no significant differences between the deposition of cobalt-60 onto pre-oxidised and new metal surfaces. In Phase 1 of the experiment, Co-60 deposition rates (normalised to the circulating Co-60 concentration) were lower than those measured in previous experiments in the loop by factors in the range from 5 to 10. In Phase 2, differences were observed in the behaviour of iron- and nickel-based alloys: larger decreases in the deposition rate compared with Phase 1 took place for stainless steel samples (i.e. factors > 20), whilst decreases on nickel-based coupons were generally less than a factor of 5. Co-60 deposition rates onto stainless steel coupons newly installed for Phase 3 of the experiment were greater by an order of magnitude than on coupons which had been exposed for all three phases; i.e. they were similar to those observed in Phase 1. The mechanisms by which zinc acts to inhibit corrosion and the incorporation of activity into oxide layers are not fully understood. More experimental data are required to resolve this issue, including information on the chemical form of the zinc within the oxide layer. (author)

  14. Comparative study of G2 delay and survival after /sup 241/Americium-. cap alpha. and /sup 60/Cobalt-. gamma. irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Luecke-Huhle, C.; Comper, W.; Hieber, L.; Pech, M.

    1982-06-01

    Survival and G2 delay following exposure to either /sup 60/Cobalt-..gamma..-rays or /sup 241/Americium-..cap alpha..-particles were studied in eight mammalian cell lines of human and animal origin including human fibroblasts from normal individuals and from patients with Ataxia telangiectasia or Fanconi's anemia. For both endpoints the effectiveness of alpha particle was greater as compared to ..gamma..-rays. RBE values for G2 delay (4.6-9.2) were in general comparable to RBE values derived from initial slopes of survival curves but higher compared to the ratio of mean inactivation doses. Ataxia cells were particularly sensitive to cell killing by ..gamma..-irradiation, however, showed average sensitivity to ..cap alpha..-particles of high LET. With the exception of Ataxia cells, cell killing and G2 delay seem to be related processes if individual cell cycle parameters are taken into account.

  15. Mitigation of cesium and cobalt contamination on the surfaces of RAM packages

    International Nuclear Information System (INIS)

    Krumhansl, J.; Bonhomme, F.; McConnell, P.; Kapoor, A.

    2004-01-01

    Techniques for mitigating the adsorption of 137 Cs and 60 Co on metal surfaces (e.g., RAM packages) exposed to contaminated water (e.g., spent-fuel pools) has been developed and experimentally verified. The techniques are also effective in removing some of the 60 Co and 137 Cs that may have been adsorbed on the surfaces after removal from the contaminated water. The principle for the 137 Cs mitigation technique is based upon ion-exchange processes. In contrast, 60 Co contamination primarily resides in minute particles of CRUD that become lodged on cask surfaces. CRUD is an insoluble Fe-Ni-Cr oxide that forms colloidal-sized particles as stainless steels corrode. Because of the similarity between Ni +2 and Co +2 , CRUD is able to scavenge and retain traces of cobalt as it forms. A number of organic compounds have a great specificity for combining with nickel and cobalt. Ongoing research is investigating the effectiveness of chemical complexing agent, EDTA, with regard to its ability to dissolve the host phase (CRUD) thereby liberating the entrained 60Co into a solution where it can be rinsed away

  16. Role of physicist in development of palliative care services in a radiotherapy dept

    International Nuclear Information System (INIS)

    Vijay Kumar, Anand

    2001-01-01

    Radiotherapy Center at Padhar Hospital has been in existence since 1982 and through external cobalt therapy 8888 patients have received treatment while over 1200 patients have received brachytherapy treatment, both intracavitary and interstitial. Situated in tribal district of Betul of Madhya Pradesh, Padhar Hospital caters to, the needs of cancer patients from over 400 km radius in Madhya Pradesh and Maharashtra, as there is no tertiary level hospital in a radius of 200 km

  17. Characterization of naturally occurring radioactive materials and Cobald-60 contaminated ferrous scraps from steel industries

    International Nuclear Information System (INIS)

    Chao, H.E.; Chiu, H.S.; Hunga, J.Y.; His, H.W.; Chen, Y.B.

    2002-01-01

    Since the occurrence of radioactively contaminated rebar incident in 1992, steel industries in Taiwan were encouraged by Atomic Energy Council (AEC) to install portal monitor to detect the abnormal radiation in shipments of metal scrap feed. From 1994 through 1999, there were 53 discoveries of radioactivity in ferrous scraps by steel companies. These include 15 orphan radioactive sources, 16 cobalt-60 contaminated rebars, 20 Naturally Occurring Radioactive Material (NORM) contaminated scraps, and two unknowns. Most NORM-contaminated scraps were from abroad. The NORM and cobalt-60 contaminated scraps were taken from the steel mills and analyzed in laboratory. The analytical results of scales and sludge sampled from NORM-contaminated scraps combining with the circumstantial evidences indicate that five possible industrial processes may be involved. They are oil production and treatment, heavy mineral sand benefication and rare earth processing, copper mining and processing, recovery of ammonium chloride by lime adsorption in Ammonium-soda process, and tailing of uranium enrichment process. The cobalt-60 activity and trace elements concentrations of contaminated rebars confirm that all of them were produced domestically in the period from Oct. 1982 to Jan. 1983, when the cobalt-60 sources were lost and entered the electric arc furnace to produce the contaminated rebars. (author)

  18. Evaluation value of coronary CTA for coronary plaque features and its correlation with platelet function and serum biochemical indexes

    Directory of Open Access Journals (Sweden)

    Jin-Xia Yang

    2017-01-01

    Full Text Available Objective: To analyze the evaluation value of coronary CT angiography for coronary plaque features and its correlation with platelet function and serum biochemical indexes. Methods: A total of 450 patients with coronary heart disease were divided into calcified plaque group (CT value≥130HU (n=117, soft plaque group (CT value≤60HU (n=150 and mixed plaque group (CT value 60-130HU (n=183 by coronary CT angiography (CTA, and 100 healthy subjects who received physical examination in our hospital during the same period were selected as control group. Differences in platelet function and serum biochemical indexes were compared among four groups of patients, and the judgment value of atheromatous plaque CT value from CTA for the severity of coronary heart disease was analyzed. Results: Platelet function parameters MPV, TEG-MA, P-selectin, PDGF-BB and vWF levels in peripheral blood of soft plaque group were higher than those of the other three groups; inflammatory factors CRP, IL-6, IL-12, IL-18 and IL-23 content in serum were higher than those of the other three groups; chemokines MCP-1, CXCL16, Fractalkine and RANTES content in serum were higher than those of the other three groups; adipocytokines Leptin and RBP4 content in serum were higher than those of the other three groups while SFRP5 content was lower than those of the other three groups. Atheromatous plaque CT value in patients with coronary heart disease was directly correlated with platelet function and the content of serum biochemical indexes. Conclusions: Coronary CTA can accurately assess coronary atheromatous plaque features, and can also be a reliable noninvasive method to judge coronary heart disease severity, treatment prognosis and so on.

  19. Quantification of carotid artery plaque stability with multiple region of interest based ultrasound strain indices and relationship with cognition

    Science.gov (United States)

    Meshram, N. H.; Varghese, T.; Mitchell, C. C.; Jackson, D. C.; Wilbrand, S. M.; Hermann, B. P.; Dempsey, R. J.

    2017-08-01

    Vulnerability and instability in carotid artery plaque has been assessed based on strain variations using noninvasive ultrasound imaging. We previously demonstrated that carotid plaques with higher strain indices in a region of interest (ROI) correlated to patients with lower cognition, probably due to cerebrovascular emboli arising from these unstable plaques. This work attempts to characterize the strain distribution throughout the entire plaque region instead of being restricted to a single localized ROI. Multiple ROIs are selected within the entire plaque region, based on thresholds determined by the maximum and average strains in the entire plaque, enabling generation of additional relevant strain indices. Ultrasound strain imaging of carotid plaques, was performed on 60 human patients using an 18L6 transducer coupled to a Siemens Acuson S2000 system to acquire radiofrequency data over several cardiac cycles. Patients also underwent a battery of neuropsychological tests under a protocol based on National Institute of Neurological Disorders and Stroke and Canadian Stroke Network guidelines. Correlation of strain indices with composite cognitive index of executive function revealed a negative association relating high strain to poor cognition. Patients grouped into high and low cognition groups were then classified using these additional strain indices. One of our newer indices, namely the average L  -  1 norm with plaque (AL1NWP) presented with significantly improved correlation with executive function when compared to our previously reported maximum accumulated strain indices. An optimal combination of three of the new indices generated classifiers of patient cognition with an area under the curve (AUC) of 0.880, 0.921 and 0.905 for all (n  =  60), symptomatic (n  =  33) and asymptomatic patients (n  =  27) whereas classifiers using maximum accumulated strain indices alone provided AUC values of 0.817, 0.815 and 0

  20. Cobalt oxide nanoparticle-modified carbon nanotubes as an ...

    Indian Academy of Sciences (India)

    of 60 mV were observed at. 100 mV s. −1 for CoOx−MWNT/GCE. An anodic peak at. 100 mV attributed to Co(II)/Co(III) redox transition associated with the electrode surface. The cathodic peak at 20 mV corre- spond to the reduction of various cobalt oxide species formed during the anodic sweep. The stability of the modified ...

  1. Programme of hot points eradication (Co-60) led on French PWR type reactors

    International Nuclear Information System (INIS)

    Rocher, A.; Ridoux, P.; Anthoni, S.; Brun, C.

    1998-01-01

    The question of hot points (pellets rich in cobalt 59 or in cobalt 60 in a PWR type reactor), is studied from the radiation protection point of view. The purpose is to see how to optimize the radiation protection, the elimination of these hot points can bring an improvement. (N.C.)

  2. Selection of the optimal radiotherapy technique for locally advanced hepatocellular carcinoma

    International Nuclear Information System (INIS)

    Lee, Ik-Jae; Seong, Jinsil; Koom, Woong-Sub; Kim, Yong-Bae; Jeon, Byeong-Chul; Kim, Joo-Ho; Han, Kwang-Hyub

    2011-01-01

    Various techniques are available for radiotherapy of hepatocellular carcinoma, including three-dimensional conformal radiotherapy, linac-based intensity-modulated radiotherapy and helical tomotherapy. The purpose of this study was to determine the optimal radiotherapy technique for hepatocellular carcinoma. Between 2006 and 2007, 12 patients underwent helical tomotherapy for locally advanced hepatocellular carcinoma. Helical tomotherapy computerized radiotherapy planning was compared with the best computerized radiotherapy planning for three-dimensional conformal radiotherapy and linac-based intensity-modulated radiotherapy for the delivery of 60 Gy in 30 fractions. Tumor coverage was assessed by conformity index, radical dose homogeneity index and moderated dose homogeneity index. Computerized radiotherapy planning was also compared according to the tumor location. Tumor coverage was shown to be significantly superior with helical tomotherapy as assessed by conformity index and moderated dose homogeneity index (P=0.002 and 0.03, respectively). Helical tomotherapy showed significantly lower irradiated liver volume at 40, 50 and 60 Gy (V40, V50 and V60, P=0.04, 0.03 and 0.01, respectively). On the contrary, the dose-volume of three-dimensional conformal radiotherapy at V20 was significantly smaller than those of linac-based intensity-modulated radiotherapy and helical tomotherapy in the remaining liver (P=0.03). Linac-based intensity-modulated radiotherapy showed better sparing of the stomach compared with helical tomotherapy in the case of separated lesions in both lobes (12.3 vs. 24.6 Gy). Helical tomotherapy showed the high dose-volume exposure to the left kidney due to helical delivery in the right lobe lesion. Helical tomotherapy achieved the best tumor coverage of the remaining normal liver. However, helical tomotherapy showed much exposure to the remaining liver at the lower dose region and left kidney. (author)

  3. The inter-observer agreement in the assessment of carotid plaque neovascularization by contrast-enhanced ultrasonography: The impact of plaque thickness.

    Science.gov (United States)

    Chen, Jian; Zhang, Yan-Ming; Song, Ze-Zhou; Fu, Yan-Fei; Geng, Yu

    2018-04-10

    The interobserver agreement in the assessment of the grade of carotid plaque neovascularization by contrast-enhanced ultrasonography is poorly established. We examined 140 carotid plaques in 66 patients (all patients had bilateral plaques, and 8 patients had 2 plaques on one side). We performed conventional and contrast-enhanced ultrasonography to analyze the presence of carotid plaque neovascularization, which was graded by two independent observers whose interobserver agreement (κ) was evaluated according to the thickness of carotid plaque. For all carotid plaques, the mean κ was 0.689 (95% confidence interval 0.604-0.774). It was 0.689 (0.569-0.808), 0.637 (0.487-0.787), and 0.740 (0.585-0.896), respectively for carotid plaques with maximal thickness 3 mm. The interobserver agreement for assessing carotid plaque neovascularization by using contrast-enhanced ultrasonography is substantial and acceptable for research purposes, regardless of the maximal thickness of the plaque. © 2018 Wiley Periodicals, Inc.

  4. Radiation incidents with a cobalt-60 teletherapy unit

    Energy Technology Data Exchange (ETDEWEB)

    Lane, R G; Tolbert, D D; Pailwal, B R; Radtke, R R [Wisconsin Univ., Madison (USA). Dept. of Radiology

    1976-08-01

    Three radiation incidents associated with source drive failures on one particular /sup 60/Co teletherapy unit, which took place during a single year's operation, are discussed. In each case the extra treatment time of the patient, the exposure to the technician, the cause of the breakdown and the subsequent action taken are detailed. Recommendations for users of /sup 60/Co teletherapy units to minimise the results of the malfunctioning of such a system are given.

  5. Radiation incidents with a cobalt-60 teletherapy unit

    International Nuclear Information System (INIS)

    Lane, R.G.; Tolbert, D.D.; Pailwal, B.R.; Radtke, R.R.

    1976-01-01

    Three radiation incidents associated with source drive failures on one particular 60 Co teletherapy unit, which took place during a single year's operation, are discussed. In each case the extra treatment time of the patient, the exposure to the technician, the cause of the breakdown and the subsequent action taken are detailed. Recommendations for users of 60 Co teletherapy units to minimise the results of the malfunctioning of such a system are given. (U.K.)

  6. A study of plaque vascularization and inflammation using quantitative contrast-enhanced US and PET/CT

    International Nuclear Information System (INIS)

    Hjelmgren, Ola; Johansson, Lars; Prahl, Ulrica; Schmidt, Caroline; Fredén-Lindqvist, Johan; Bergström, Göran M.L.

    2014-01-01

    Background: Contrast-enhanced ultrasound (CEUS) is an in vivo methodology to quantify carotid plaque vascularization. Increased metabolism in plaques, measured as FDG uptake in PET/CT examination, has been associated with markers of inflammation in histological samples. In this study, we tested the association between FDG uptake and vascularization measured by CEUS to assess whether CEUS can be used as an in vivo marker of plaque vulnerability. Methods: After informed consent, subjects aged >60 years with carotid plaque height exceeding 2.5 mm were recruited. CEUS was performed and analyzed using earlier described protocol and software, Contrast Quantification Program, which calculates the fraction of the plaque being contrast positive (CQP value). PET/CT examination was performed within 3 months of CEUS (median time 7 days). PET/CT images were acquired 90 min after FDG injection (2.7 MBq/kg). FDG uptake was measured as tissue background index (TBI), calculated using Spearman's rho as mean standard uptake value (SUV) of the plaque divided by mean SUV in the jugular vein (mean of 7 measuring points). Local ethics committee approved the study. Results: We recruited 13 subjects (5 women) with a mean age of 71 years, 6 had a history of stroke or TIA, 1 had a history of ipsilateral stroke. CQP values showed a significant, positive correlation with TBI of carotid plaques, r = 0.67, p < 0.02. Conclusions: Plaque vascularization measured by CEUS correlates positively with FDG uptake measured by PET/CT in humans. This indicates an association between vascularization and inflammation and/or hypoxia, supporting the use of CEUS as a non-invasive method to detect plaque vulnerability

  7. A study of plaque vascularization and inflammation using quantitative contrast-enhanced US and PET/CT

    Energy Technology Data Exchange (ETDEWEB)

    Hjelmgren, Ola, E-mail: ola.hjelmgren@wlab.gu.se [Institute of Medicine, Sahlgrenska Academy at the University of Gothenburg, Department of Molecular and Clinical Medicine, Clinical Physiology, Gothenburg (Sweden); Sahlgrenska University Hospital, Department of Clinical Physiology, Gothenburg (Sweden); Johansson, Lars, E-mail: lars.johansson@radiol.uu.se [Uppsala University, Department of Radiology, Uppsala (Sweden); Prahl, Ulrica, E-mail: ulrica-prahl-gullberg@wlab.gu.se [Institute of Medicine, Sahlgrenska Academy at the University of Gothenburg, Department of Molecular and Clinical Medicine, Clinical Physiology, Gothenburg (Sweden); Schmidt, Caroline, E-mail: caroline.schmidt@wlab.gu.se [Institute of Medicine, Sahlgrenska Academy at the University of Gothenburg, Department of Molecular and Clinical Medicine, Clinical Physiology, Gothenburg (Sweden); Fredén-Lindqvist, Johan, E-mail: johan.freden-lindqvist@vgregion.se [Sahlgrenska University Hospital, Department of Clinical Physiology, Gothenburg (Sweden); Bergström, Göran M.L., E-mail: goran.bergstrom@hjl.gu.se [Institute of Medicine, Sahlgrenska Academy at the University of Gothenburg, Department of Molecular and Clinical Medicine, Clinical Physiology, Gothenburg (Sweden); Sahlgrenska University Hospital, Department of Clinical Physiology, Gothenburg (Sweden)

    2014-07-15

    Background: Contrast-enhanced ultrasound (CEUS) is an in vivo methodology to quantify carotid plaque vascularization. Increased metabolism in plaques, measured as FDG uptake in PET/CT examination, has been associated with markers of inflammation in histological samples. In this study, we tested the association between FDG uptake and vascularization measured by CEUS to assess whether CEUS can be used as an in vivo marker of plaque vulnerability. Methods: After informed consent, subjects aged >60 years with carotid plaque height exceeding 2.5 mm were recruited. CEUS was performed and analyzed using earlier described protocol and software, Contrast Quantification Program, which calculates the fraction of the plaque being contrast positive (CQP value). PET/CT examination was performed within 3 months of CEUS (median time 7 days). PET/CT images were acquired 90 min after FDG injection (2.7 MBq/kg). FDG uptake was measured as tissue background index (TBI), calculated using Spearman's rho as mean standard uptake value (SUV) of the plaque divided by mean SUV in the jugular vein (mean of 7 measuring points). Local ethics committee approved the study. Results: We recruited 13 subjects (5 women) with a mean age of 71 years, 6 had a history of stroke or TIA, 1 had a history of ipsilateral stroke. CQP values showed a significant, positive correlation with TBI of carotid plaques, r = 0.67, p < 0.02. Conclusions: Plaque vascularization measured by CEUS correlates positively with FDG uptake measured by PET/CT in humans. This indicates an association between vascularization and inflammation and/or hypoxia, supporting the use of CEUS as a non-invasive method to detect plaque vulnerability.

  8. Synthesis, analysis and radiolysis of the cobalt III 8 hydroxyquinolinate complex

    International Nuclear Information System (INIS)

    Mestnik, S.A.C.; Silva, C.P.G. da.

    1981-11-01

    The cobalt III 8-hidroxyquinolinate complex was syntetized from a solution of cobalt II. The compound was analysed by IR absorption spectroscopy, elemental analysis and by the determination of number of ligands. The radiolytic degradation was verified by spectrophotometry after submitting samples of 10 - 3 M complex in ethanolic solution to different doses of gamma radiation from a 60 Co source. The change of maximum absorbance of the complex with different doses of gamma radiation and its UV-VIS absorption spectra are presented. The complex in the solid state was also irradiated with 6,9 Mrad of gamma radiation but it didn't present degradation. (Author) [pt

  9. Chest wall desmoid tumours treated with definitive radiotherapy: a plan comparison of 3D conformal radiotherapy, intensity-modulated radiotherapy and volumetric-modulated arc radiotherapy

    International Nuclear Information System (INIS)

    Liu, Jia; Ng, Diana; Lee, James; Stalley, Paul; Hong, Angela

    2016-01-01

    Definitive radiotherapy is often used for chest wall desmoid tumours due to size or anatomical location. The delivery of radiotherapy is challenging due to the large size and constraints of normal surrounding structures. We compared the dosimetry of 3D conformal radiotherapy (3DCRT), intensity-modulated radiotherapy (IMRT) and volumetric-modulated arc radiotherapy (VMAT) to evaluate the best treatment option. Ten consecutive patients with inoperable chest wall desmoid tumours (PTV range 416–4549 cm 3 ) were selected. For each patient, 3DCRT, IMRT and VMAT plans were generated and the Conformity Index (CI), organ at risk (OAR) doses and monitor unit (MU) were evaluated. The Wilcoxon signed-rank test was used to compare dose delivered to both target and OARs. The mean number of fields for 3DCRT and IMRT were 6.3 ± 2.1, 7.2 ± 1.8. The mean number of arcs for VMAT was 3.7 ± 1.1. The mean conformity index of VMAT (0.98 ± 0.14) was similar to that of IMRT (1.03 ± 0.13), both of which were significantly better than 3DCRT (1.35 ± 0.20; p = 0.005). The mean dose to lung was significantly higher for 3DCRT (11.9Gy ± 7.9) compared to IMRT (9.4Gy ± 5.4, p = 0.014) and VMAT (8.9Gy ± 4.5, p = 0.017). For the 3 females, the low dose regions in the ipsilateral breast for VMAT were generally less with VMAT. IMRT plans required 1427 ± 532 MU per fraction which was almost 4-fold higher than 3DCRT (313 ± 112, P = 0.005). Compared to IMRT, VMAT plans required 60 % less MU (570 ± 285, P = 0.005). For inoperable chest wall desmoid tumours, VMAT delivered equivalent target coverage when compared to IMRT but required 60 % less MU. Both VMAT and IMRT were superior to 3DCRT in terms of better PTV coverage and sparing of lung tissue

  10. Radiation accident of 60Co contamination. Mexico 1984

    International Nuclear Information System (INIS)

    1985-01-01

    The action taken to mitigate the consequences of a radiation accident occuring in the State of Chihuahua, Mexico, is described, when a no longer in use cobalt-60 teletherapy unit, with radioactive pellets still inside, was sold, unwittingly as ordinary scrap to be finally made into reinforced steel rods. The finished metallic items, unknowingly contaminated with cobalt-60, were subsequently sold in central and northern Mexico and in the United States of America. The junkyard, transport vehicle, several foundries and some streets of two cities and the road between them were also made radioactive by the accident. The discovery of and search for the radioactive metallic products is described as is their final disposal and the decontamination of the affected sites. Individual and collective radiation doses is estimated. (author)

  11. Effects of gamma radiation of Cobalt-60 on arabica and conillon seeds coffea: physic-chemistry evaluation

    International Nuclear Information System (INIS)

    Silva, Marcus Henriques da

    2012-01-01

    Brazil is the largest producer and exporter of coffee in the world. The coffee bean is one of the main products of the Brazilian trade balance. Two species of coffee are the most economically important: the Coffea arabica L. and Coffea canephora Pierre is the largest representative of the Coffea canephora Pierre is the coffea conillon. Food irradiation is an area of research that aims to increase the shelf life of foods and controlling pests. This study aimed to verify the physicochemical variables of Arabica coffee and conillon were affected when exposed to doses of gamma radiation from cobalt-60. The samples were provided by Polo in Coffee Quality Technology, Federal University of Lavras - UFLA. The coffee samples were subjected to irradiation doses: 0 (control), 5 kGy and 10 kGy, a multipurpose irradiator of IPEN - Research Institute of Nuclear Energy and the University of São Paulo, at a rate of 7.5 kGy / hour. For irradiation the samples were vacuum-packed in appropriate packaging aluminised. After the process of irradiation the samples were stored at a temperature of 15 ± 1 deg C and relative humidity of 17 ± 1%. The following analyzes were performed: levels of total sugars, glucose, sucrose, caffeine, humidity, pH, total acidity, electrical conductivity and fibers. Analyses were performed 1, 30, 60 and 90 days after irradiation, and the results were submitted to analysis of variance and means were compared by Tukey test at 5%. It was observed that the analysis results of the samples irradiated with 5 kGy and 10 kGy showed values similar to the control. It was concluded that irradiation did not induce deleterious effects on arabica coffee seeds and conillon irradiated with 5 kGy and 10 kGy to 90 days after irradiation. (author)

  12. Predicting carotid artery disease and plaque instability from cell-derived microparticles.

    Science.gov (United States)

    Wekesa, A L; Cross, K S; O'Donovan, O; Dowdall, J F; O'Brien, O; Doyle, M; Byrne, L; Phelan, J P; Ross, M D; Landers, R; Harrison, M

    2014-11-01

    Cell-derived microparticles (MPs) are small plasma membrane-derived vesicles shed from circulating blood cells and may act as novel biomarkers of vascular disease. We investigated the potential of circulating MPs to predict (a) carotid plaque instability and (b) the presence of advanced carotid disease. This pilot study recruited carotid disease patients (aged 69.3 ± 1.2 years [mean ± SD], 69% male, 90% symptomatic) undergoing endarterectomy (n = 42) and age- and sex-matched controls (n = 73). Plaques were classified as stable (n = 25) or unstable (n = 16) post surgery using immunohistochemistry. Blood samples were analysed for MP subsets and molecular biomarkers. Odds ratios (OR) are expressed per standard deviation biomarker increase. Endothelial MP (EMP) subsets, but not any vascular, inflammatory, or proteolytic molecular biomarker, were higher (p < .05) in the unstable than the stable plaque patients. The area under the receiver operator characteristic curve for CD31(+)41(-) EMP in discriminating an unstable plaque was 0.73 (0.56-0.90, p < .05). CD31(+)41(-) EMP predicted plaque instability (OR = 2.19, 1.08-4.46, p < .05) and remained significant in a multivariable model that included transient ischaemic attack symptom status. Annexin V(+) MP, platelet MP (PMP) subsets, and C-reactive protein were higher (p < .05) in cases than controls. Annexin V(+) MP (OR = 3.15, 1.49-6.68), soluble vascular cell adhesion molecule-1 (OR = 1.64, 1.03-2.59), and previous smoking history (OR = 3.82, 1.38-10.60) independently (p < .05) predicted the presence of carotid disease in a multivariable model. EMP may have utility in predicting plaque instability in carotid patients and annexin V(+) MPs may predict the presence of advanced carotid disease in aging populations, independent of established biomarkers. Copyright © 2014 European Society for Vascular Surgery. Published by Elsevier Ltd. All rights reserved.

  13. Uptake of radionuclides caesium and cobalt

    International Nuclear Information System (INIS)

    Lukac, P.; Foldesova, M.

    1995-01-01

    By means of chemical treatment ammonium, potassium, sodium and H-form of zeolite were prepared. The chemical modifications of zeolite were carried out with: 2M solution of NaNO 3 , NH 4 NO 3 , KNO 3 ; 0,1M solution of HCl; NaOH solution of different concentration. The method of model radioactive solution was used to find the sorption ability for cesium and cobalt every modified zeolite. The model solution were 0.05M solution of cobalt labelled by 60 Co or cesium labelled by 137 Cs. The highest sorption ability was observed for zeolite modified by NaOH. The influence of pH on uptake of cesium and cobalt by modified zeolite was searched as well. The experimental data (leaching tests, compressive strength measurement and porosity) were measured for the case the Cs and Cs from model water solution and radioactive waste water were up taken on chemically modified zeolite and were subsequently incorporated into cement casts on blast furnace cement slags basis. The leachability was tested in water, in basis solution and in acid solution. The leachability in water and basic solution was negligible, in acid solution it was less than 4% which is inside of value of applied measure method. The compressive strength, porosity and leaching experiment are hopefully and show good mechanical stability and good retention of observed radionuclides in samples exposed in leaching solutions. (J.K.)

  14. Uptake of radionuclides caesium and cobalt

    Energy Technology Data Exchange (ETDEWEB)

    Lukac, P; Foldesova, M [Slovak Technical Univ., Bratislava (Slovakia)

    1996-12-31

    By means of chemical treatment ammonium, potassium, sodium and H-form of zeolite were prepared. The chemical modifications of zeolite were carried out with: 2M solution of NaNO{sub 3}, NH{sub 4}NO{sub 3}, KNO{sub 3}; 0,1M solution of HCl; NaOH solution of different concentration. The method of model radioactive solution was used to find the sorption ability for cesium and cobalt every modified zeolite. The model solution were 0.05M solution of cobalt labelled by {sup 60}Co or cesium labelled by {sup 137}Cs. The highest sorption ability was observed for zeolite modified by NaOH. The influence of pH on uptake of cesium and cobalt by modified zeolite was searched as well. The experimental data (leaching tests, compressive strength measurement and porosity) were measured for the case the Cs and Cs from model water solution and radioactive waste water were up taken on chemically modified zeolite and were subsequently incorporated into cement casts on blast furnace cement slags basis. The leachability was tested in water, in basis solution and in acid solution. The leachability in water and basic solution was negligible, in acid solution it was less than 4% which is inside of value of applied measure method. The compressive strength, porosity and leaching experiment are hopefully and show good mechanical stability and good retention of observed radionuclides in samples exposed in leaching solutions. (J.K.).

  15. Kinetics of hemolytic plaque formation. IV. IgM plaque inhibition

    Energy Technology Data Exchange (ETDEWEB)

    DeLisi, C

    1975-01-01

    An analysis of the inhibition of hemolytic plaques formed against IgM antibodies is presented. The starting point is the equations of DeLisi and Bell (1974) which describe the kinetics of plaque growth, and DeLisi and Goldstein (1975) which describe inhibition of IgG plaques. However, the physical chemical models which were used previously to describe IgG inhibition data are shown to be inadequate for describing the characteristics of IgM inhibition curves. Moreover, it is shown that the experimental results place severe restrictions on the possible choices of physical chemical models for IgM upon which to base the calculations. It is argued that in order to account even qualitatively for all the data, one must assume (1) a very restricted motion of IgMs about the Fab hinge region and (2) a very narrow secretion rate distribution of IgM by antibody secreting cells. (auth)

  16. CT coronary angiography: impact of adapted statistical iterative reconstruction (ASIR) on coronary stenosis and plaque composition analysis.

    Science.gov (United States)

    Fuchs, Tobias A; Fiechter, Michael; Gebhard, Cathérine; Stehli, Julia; Ghadri, Jelena R; Kazakauskaite, Egle; Herzog, Bernhard A; Husmann, Lars; Gaemperli, Oliver; Kaufmann, Philipp A

    2013-03-01

    To assess the impact of adaptive statistical iterative reconstruction (ASIR) on coronary plaque volume and composition analysis as well as on stenosis quantification in high definition coronary computed tomography angiography (CCTA). We included 50 plaques in 29 consecutive patients who were referred for the assessment of known or suspected coronary artery disease (CAD) with contrast-enhanced CCTA on a 64-slice high definition CT scanner (Discovery HD 750, GE Healthcare). CCTA scans were reconstructed with standard filtered back projection (FBP) with no ASIR (0 %) or with increasing contributions of ASIR, i.e. 20, 40, 60, 80 and 100 % (no FBP). Plaque analysis (volume, components and stenosis degree) was performed using a previously validated automated software. Mean values for minimal diameter and minimal area as well as degree of stenosis did not change significantly using different ASIR reconstructions. There was virtually no impact of reconstruction algorithms on mean plaque volume or plaque composition (e.g. soft, intermediate and calcified component). However, with increasing ASIR contribution, the percentage of plaque volume component between 401 and 500 HU decreased significantly (p ASIR, which has been developed for noise reduction in latest high resolution CCTA scans, can be used reliably without interfering with the plaque analysis and stenosis severity assessment.

  17. The efficacy of honey solution as plaque reducing agent

    Directory of Open Access Journals (Sweden)

    Dewi Nurul M

    2010-06-01

    Full Text Available Background: Periodontal care is an important step of periodontal health management. Some chemically active substances have been studied as an adjunct to mechanical plaque control. Honey is a traditional topical treatment for infected wounds and have inhibitory effect to around 60 species of bacteria including aerobes and anaerobes, gram-positives and gram-negatives. Purpose: To compare the efficacy of 5% and 25% honey solution and aquadest as mouth-rinses to control dental plaque during 4 days period. Method: After a thorough prophylaxis, during 4 days period of no oral hygiene all subjects were rinsed with 10 ml mouth-rinse they received 3 times a day after meal. Group I rinse with 5% honey solution, group II with 25%, and group III with aquadest as control. Results: There were significant increases of plaque index within each group, but no differences between all three groups in every experimental day. The fact that the probability value from day 1 (0.766 were gradually decreased to day 4 (0.076. Conclusion: Anti-microbial properties of honey solution as mouth-rinse did not show any inhibition effect on plaque formation until day 4.Latar belakang: Menjaga kesehatan periodontal merupakan tahap penting dalam pemeliharaan kesehatan periodontal. Beberapa substansi kimiawi aktif telah diteliti untuk membantu dalam kontrol plak gigi secara mekanik. Madu merupakan obat tradisional untuk luka terinfeksi dan dinyatakan mempunyai pengaruh menghambat sekitar 60 spesies termasuk bakteri aerob dan anaerob gram positif dan gram negatif. Tujuan: Membandingkan manfaat larutan madu 5% dan 25% terhadap akuades sebagai obat kumur untuk mengontrol pembentukan plak gigi selama 4 hari penelitian. Metode: Setelah tindakan profilaksis pembersihan sempurna, semua subjek penelitian dipersilahkan berkumur dengan 10 ml larutan yang telah diterima, 3 kali sehari setelah makan. Kelompok 1 berkumur dengan larutan madu 5%, kelompok 2 dengan 25%, dan kelompok 3 dengan akuades

  18. Design of database management system for 60Co container inspection system

    International Nuclear Information System (INIS)

    Liu Jinhui; Wu Zhifang

    2007-01-01

    The function of the database management system has been designed according to the features of cobalt-60 container inspection system. And the software related to the function has been constructed. The database querying and searching are included in the software. The database operation program is constructed based on Microsoft SQL server and Visual C ++ under Windows 2000. The software realizes database querying, image and graph displaying, statistic, report form and its printing, interface designing, etc. The software is powerful and flexible for operation and information querying. And it has been successfully used in the real database management system of cobalt-60 container inspection system. (authors)

  19. Second Study of Hyper-Fractionated Radiotherapy

    Directory of Open Access Journals (Sweden)

    R. Jacob

    1999-01-01

    Full Text Available Purpose and Method. Hyper-fractionated radiotherapy for treatment of soft tissue sarcomas is designed to deliver a higher total dose of radiation without an increase in late normal tissue damage. In a previous study at the Royal Marsden Hospital, a total dose of 75 Gy using twice daily 1.25 Gy fractions resulted in a higher incidence of late damage than conventional radiotherapy using 2 Gy daily fractions treating to a total of 60 Gy. The current trial therefore used a lower dose per fraction of 1.2 Gy and lower total dose of 72 Gy, with 60 fractions given over a period of 6 weeks.

  20. Animal models to study plaque vulnerability

    NARCIS (Netherlands)

    Schapira, K.; Heeneman, S.; Daemen, M. J. A. P.

    2007-01-01

    The need to identify and characterize vulnerable atherosclerotic lesions in humans has lead to the development of various animal models of plaque vulnerability. In this review, current concepts of the vulnerable plaque as it leads to an acute coronary event are described, such as plaque rupture,

  1. Effects of 60 Cobalt ionizing radiation in morphology and metabolism of yeasts and Chlamydospore of Candida albicans

    International Nuclear Information System (INIS)

    Grillo, Michel R.F.; Demicheli, Marina C.; Andrade Junior, Heitor F.; Galiesteo Junior, Andres A.J.

    2015-01-01

    Candida albicans is a fungus responsible for 80-90% of fungal infections, as the symptoms are similar to those of systemic bacterial infections there is a difficulty for immediate diagnosis. These difficulties can lead to delays of antifungal therapy, which contributes to the high mortality rates associated with this infection. Resistance structures referred to as chlamydospores are very common in the pathogen, representing different cell types that form in response to certain genetic or environmental conditions. Recently, various antifungal agents and new therapeutic strategies have come into use, allowing the fungus to acquire a resistance to the drugs. The use of ionizing radiation has been widely employed for the production of immunogens against various parasites. In this work, we evaluate the effects of gamma radiation ( 60 Co) in yeast and chlamydospore of C. albicans with doses ranging from 320 to 10.240 Gy with Cobalt 60. Subsequently the samples were plated and after seven days, the colony forming units (CFU) told. The viability of irradiated cells were evaluated using the Janus green dye. A dose of 6000 Gy was considered ideal for the mitigation of chlamydospore and yeast. The dimorphic change mechanisms of both fungal structures were not harmed. The viability of chlamydospores remained above 70% while the yeast viability remained above 85%. By transmission electron microscopy and fluorescence microscopy may be noted cytoplasmic changes, defects in the cell wall, mitochondria, and the presence of partially preserved vesicles of both morphological forms of C. albicans. Irradiation both chlamydospore as C. albicans yeast allows the suppression of their reproduction, opening the possibility of their use in future candidate immunogens. (author)

  2. Effects of 60 Cobalt ionizing radiation in morphology and metabolism of yeasts and Chlamydospore of Candida albicans

    Energy Technology Data Exchange (ETDEWEB)

    Grillo, Michel R.F.; Demicheli, Marina C.; Andrade Junior, Heitor F.; Galiesteo Junior, Andres A.J., E-mail: galisteo@usp.br [Universidade de Sao Paulo (IMTSP/USP), Sao Paulo, SP (Brazil). Instituto de Medicina Tropical. Lab. de Protozoologia; Takakura, Cleusa F.H. [Universidade de Sao Paulo (FM/USP), Sao Paulo, SP (Brazil). Departamento de Patologia de Molestias Transmissiveis. Lab. de Patologia; Negro, Gilda M.B. del [Universidade de Sao Paulo (HCFM/USP/IMTSP/LIM-53), Sao Paulo, SP (Brazil). Hospital das Clinicas. Lab. de Micologia; Nascimento, Nanci do [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2015-07-01

    Candida albicans is a fungus responsible for 80-90% of fungal infections, as the symptoms are similar to those of systemic bacterial infections there is a difficulty for immediate diagnosis. These difficulties can lead to delays of antifungal therapy, which contributes to the high mortality rates associated with this infection. Resistance structures referred to as chlamydospores are very common in the pathogen, representing different cell types that form in response to certain genetic or environmental conditions. Recently, various antifungal agents and new therapeutic strategies have come into use, allowing the fungus to acquire a resistance to the drugs. The use of ionizing radiation has been widely employed for the production of immunogens against various parasites. In this work, we evaluate the effects of gamma radiation ({sup 60}Co) in yeast and chlamydospore of C. albicans with doses ranging from 320 to 10.240 Gy with Cobalt 60. Subsequently the samples were plated and after seven days, the colony forming units (CFU) told. The viability of irradiated cells were evaluated using the Janus green dye. A dose of 6000 Gy was considered ideal for the mitigation of chlamydospore and yeast. The dimorphic change mechanisms of both fungal structures were not harmed. The viability of chlamydospores remained above 70% while the yeast viability remained above 85%. By transmission electron microscopy and fluorescence microscopy may be noted cytoplasmic changes, defects in the cell wall, mitochondria, and the presence of partially preserved vesicles of both morphological forms of C. albicans. Irradiation both chlamydospore as C. albicans yeast allows the suppression of their reproduction, opening the possibility of their use in future candidate immunogens. (author)

  3. Dosimetric Comparison of Real-Time MRI-Guided Tri-Cobalt-60 Versus Linear Accelerator-Based Stereotactic Body Radiation Therapy Lung Cancer Plans.

    Science.gov (United States)

    Wojcieszynski, Andrzej P; Hill, Patrick M; Rosenberg, Stephen A; Hullett, Craig R; Labby, Zacariah E; Paliwal, Bhudatt; Geurts, Mark W; Bayliss, R Adam; Bayouth, John E; Harari, Paul M; Bassetti, Michael F; Baschnagel, Andrew M

    2017-06-01

    Magnetic resonance imaging-guided radiation therapy has entered clinical practice at several major treatment centers. Treatment of early-stage non-small cell lung cancer with stereotactic body radiation therapy is one potential application of this modality, as some form of respiratory motion management is important to address. We hypothesize that magnetic resonance imaging-guided tri-cobalt-60 radiation therapy can be used to generate clinically acceptable stereotactic body radiation therapy treatment plans. Here, we report on a dosimetric comparison between magnetic resonance imaging-guided radiation therapy plans and internal target volume-based plans utilizing volumetric-modulated arc therapy. Ten patients with early-stage non-small cell lung cancer who underwent radiation therapy planning and treatment were studied. Following 4-dimensional computed tomography, patient images were used to generate clinically deliverable plans. For volumetric-modulated arc therapy plans, the planning tumor volume was defined as an internal target volume + 0.5 cm. For magnetic resonance imaging-guided plans, a single mid-inspiratory cycle was used to define a gross tumor volume, then expanded 0.3 cm to the planning tumor volume. Treatment plan parameters were compared. Planning tumor volumes trended larger for volumetric-modulated arc therapy-based plans, with a mean planning tumor volume of 47.4 mL versus 24.8 mL for magnetic resonance imaging-guided plans ( P = .08). Clinically acceptable plans were achievable via both methods, with bilateral lung V20, 3.9% versus 4.8% ( P = .62). The volume of chest wall receiving greater than 30 Gy was also similar, 22.1 versus 19.8 mL ( P = .78), as were all other parameters commonly used for lung stereotactic body radiation therapy. The ratio of the 50% isodose volume to planning tumor volume was lower in volumetric-modulated arc therapy plans, 4.19 versus 10.0 ( P guided tri-cobalt-60 radiation therapy is capable of delivering lung high

  4. Cobalt metabolism and toxicology—A brief update

    International Nuclear Information System (INIS)

    Simonsen, Lars Ole; Harbak, Henrik; Bennekou, Poul

    2012-01-01

    Cobalt metabolism and toxicology are summarized. The biological functions of cobalt are updated in the light of recent understanding of cobalt interference with the sensing in almost all animal cells of oxygen deficiency (hypoxia). Cobalt (Co 2+ ) stabilizes the transcriptional activator hypoxia-inducible factor (HIF) and thus mimics hypoxia and stimulates erythropoietin (Epo) production, but probably also by the same mechanism induces a coordinated up-regulation of a number of adaptive responses to hypoxia, many with potential carcinogenic effects. This means on the other hand that cobalt (Co 2+ ) also may have beneficial effects under conditions of tissue hypoxia, and possibly can represent an alternative to hypoxic preconditioning. Cobalt is acutely toxic in larger doses, and in mammalian in vitro test systems cobalt ions and cobalt metal are cytotoxic and induce apoptosis and at higher concentrations necrosis with inflammatory response. Cobalt metal and salts are also genotoxic, mainly caused by oxidative DNA damage by reactive oxygen species, perhaps combined with inhibition of DNA repair. Of note, the evidence for carcinogenicity of cobalt metal and cobalt sulfate is considered sufficient in experimental animals, but is as yet considered inadequate in humans. Interestingly, some of the toxic effects of cobalt (Co 2+ ) have recently been proposed to be due to putative inhibition of Ca 2+ entry and Ca 2+ -signaling and competition with Ca 2+ for intracellular Ca 2+ -binding proteins. The tissue partitioning of cobalt (Co 2+ ) and its time-dependence after administration of a single dose have been studied in man, but mainly in laboratory animals. Cobalt is accumulated primarily in liver, kidney, pancreas, and heart, with the relative content in skeleton and skeletal muscle increasing with time after cobalt administration. In man the renal excretion is initially rapid but decreasing over the first days, followed by a second, slow phase lasting several weeks, and

  5. Effects of whole-body cobalt 60 gamma irradiation on the young korean native goats

    International Nuclear Information System (INIS)

    Kim, Jong Gyu; Sung, Jai Ki

    1989-01-01

    This study was carried out to investigate the effects of whole-body cobolt-60 gamma irradiation on clinical signs, mortality, hematological, blood chemical, chromosomal and pathologic changes in the young Korean native goats. Groups of goats were exposed to 200, 400, 600 and 800 rads of gamma irradiation from a cobalt-60 source. Clinical signs such as diarrhea, anorexia, weakness and depression of the irradiated goats were observed. Mortalities were 66.7 percent in the group irradiated with 200 rads and 100 percent in the groups irradiated with higher doses. Death times were shortened with the increment of irradiation doses. With time after irradiation, the values of erythrocytes, hemoglobin and packed cell volume decreased in the 200 and 400 rads groups and increased in the 600 and 800 rads groups. The number of total leukocytes of the irradiated goats decreased significantly in all irradiated groups. The degrees of decrease were severe as the irradiated doses were increased. Significant decrease of lymphocyte counts were observed from 6 hours in the 800 rads group and 1 day post irradiation(PI) in all other groups. Post irradiation times for significant reduction of neutrophils were 1, 3, 3 and 5 days for 800, 600, 400 and 200 rads groups, respectively. Serum sorbitol dehydrogenase and serum aspartate aminotransferase activities increased remarkably at 6 hours PI in the 800 rads group and 1 day PI in all other groups. Thereafter the activities returned to normal values. Since mitoses of lymphocytes were completely inhibited in blood cultures of all irradiated goats, chromosomal pictures could not be observed. However, mitoses were observed on 28 days PI in 200 rads group and no abberration in the number and structures of lymphocyte chromosomes were detected. Histopathologic findings in various organs of the irradiated goats were severe necrosis and depletion of lymphoid cells in the lymph nodes and spleen, hypoplasia of hemopoietic cells in the bone marrow

  6. Recovery of cobalt from spent lithium-ion batteries using supercritical carbon dioxide extraction.

    Science.gov (United States)

    Bertuol, Daniel A; Machado, Caroline M; Silva, Mariana L; Calgaro, Camila O; Dotto, Guilherme L; Tanabe, Eduardo H

    2016-05-01

    Continuing technological development decreases the useful lifetime of electronic equipment, resulting in the generation of waste and the need for new and more efficient recycling processes. The objective of this work is to study the effectiveness of supercritical fluids for the leaching of cobalt contained in lithium-ion batteries (LIBs). For comparative purposes, leaching tests are performed with supercritical CO2 and co-solvents, as well as under conventional conditions. In both cases, sulfuric acid and H2O2 are used as reagents. The solution obtained from the supercritical leaching is processed using electrowinning in order to recover the cobalt. The results show that at atmospheric pressure, cobalt leaching is favored by increasing the amount of H2O2 (from 0 to 8% v/v). The use of supercritical conditions enable extraction of more than 95wt% of the cobalt, with reduction of the reaction time from 60min (the time employed in leaching at atmospheric pressure) to 5min, and a reduction in the concentration of H2O2 required from 8 to 4% (v/v). Electrowinning using a leach solution achieve a current efficiency of 96% and a deposit with cobalt concentration of 99.5wt%. Copyright © 2016 Elsevier Ltd. All rights reserved.

  7. Results of the application of the Risk Evaluation System in Radiotherapy (RESRA) in radiotherapy facilities in Mexico; Resultados de la aplicacion del Sistema de Evaluacion del Riesgo en Radioterapia (SEVRRA) en instalaciones de radioterapia en Mexico

    Energy Technology Data Exchange (ETDEWEB)

    Paz G, A.; Godinez S, V., E-mail: abpaz@cnsns.gob.mx [Comision Nacional de Seguridad Nuclear y Salvaguardias, Dr. Jose Ma. Barragan No. 779, Col. Narvarte, 03020 Mexico D. F. (Mexico)

    2013-10-15

    The present work describes the main results of the risk evaluation for some radiotherapy treatments with lineal accelerators, cobalt 60, brachytherapy of high dose rate and brachytherapy of low dose rate that are realize in Mexico. These evaluations were carried out applying the risk matrices method with the tool computer risk evaluation system in radiotherapy, accessible for the national users through internet, and developed by the Comision Nacional de Seguridad Nuclear y Salvaguardias in Mexico, in cooperation with the Forum of Ibero-American regulators. The used methodology is based on the risk matrices method that is a mathematical tool for the risk evaluation, and it was centered in the evaluation from the risk to which are exposed the patients, the occupational exposed personnel and people in general, by the mechanical faults of the treatment equipment s, bad calibrations, human errors, or any other event initiator of accidents. The events initiators of accidents are defined as those undesirable events that can produce and administration of an excessive dose or a sub-dose of the prescribed dose by the doctor, to the planned objective volume, or undesirable dose to the patient's regions or dose to occupational exposed personnel or people in general. The barriers are the actions and systems as mechanical switches, interlocks or alarms, dedicated to avoid that these accidents take place. The evaluation analysis of the risk developed by the members of the Forum for radiotherapy facilities together with the software RESRA has demonstrated to be useful in the prevention of many possible accidents that have happened in the past in other facilities and can avoid many others in the future. (Author)

  8. Dosimetry on the radiological risks prevention in radiotherapy; La dosimetria en la prevencion de riesgos radiologicos en radioterapia

    Energy Technology Data Exchange (ETDEWEB)

    Fornet R, O. M.; Perez G, F., E-mail: nuclear2@citmahlg.holguin.inf.cu [Delegacion Territorial del CITMA, Peralta 16 esq. P. Feria, Rpto. Peralta, 80400 Holguin (Cuba)

    2014-08-15

    Dosimetry in its various forms plays a determining role on the radiological risks prevention in radiotherapy. To prove this in this paper is shown an analysis based on the risk matrix method, how the dosimetry can influence in each stages of a radiotherapy service; installation and acceptance, operation, maintenance and calibration. For each one of these stages the role that can play is analyzed as either the initiating event of a radiological accident or limiting barrier of these events of the dosimetric processes used for the individual dosimetry, the area monitoring, fixed or portable, for radiation beam dosimetry and of the patients for a radiotherapy service with cobalt-therapy equipment. The result of the study shows that the application of a prospective approach in the role evaluation of dosimetry in the prevention and mitigation of the consequences of a radiological accident in radiotherapy is crucial and should be subject to permanent evaluation at each development stage of these services. (author)

  9. Radiotherapy for bladder cancer and kidney cancer

    International Nuclear Information System (INIS)

    Ishikawa, Hitoshi; Tanaka, Keiichi; Iizumi, Takashi; Shimizu, Shosei; Okumura, Toshiyuki; Sakurai, Hideyuki; Kimura, Tomokazu; Nishiyama, Hiroyuki

    2017-01-01

    This paper explained the current state of radiotherapy for bladder cancer and kidney cancer, and discussed the role of radiotherapy in curative treatment and the future development. In the diagnosis and treatment of bladder cancer, it is important to judge the existence of pathological muscular layer invasion based on transurethral resection of bladder tumor (TUR-BT). In surgical results in Japan, the U.S., and Switzerland, 5-year survival rate is about 60 to 70%. Standard treatment for bladder cancer with muscle layer invasion had been surgery, and radiotherapy had been applied to the cases without resistance to surgery. Three combined therapy with TUR-BT and simultaneous chemoradiotherapy is the current standard bladder conserving therapy. The 5-year survival rate is approximately 60%, which is superior to the treatment with irradiation alone. Radiotherapy for kidney cancer is most often used as perioperative treatment for locally advanced cancer or as symptomatic treatment for metastatic lesions. However, due to recent improvement in radiotherapy technology, correspondence to respiratory movement and high dose administration associated with improvement in dose concentration have been realized, and stereotactic irradiation using a high single dose for inoperable disease cases or surgery refusal disease cases has come to be clinically applied. (A.O.)

  10. Effect of different ionizing radiation doses and dose rates, using Cobalt-60 and electrons beam sources, on the staphylococcal enterotoxin inoculated in mechanically deboned chicken meat

    International Nuclear Information System (INIS)

    Pomarico Neto, Walter; Brito, Poliana de Paula; Azevedo, Heliana de; Roque, Claudio Vitor; Fukuma, Henrique Takuji; Kodama, Yasko; Miya, Norma Terugo Nago; Pereira, Jose Luiz

    2011-01-01

    The purpose of food irradiation is the destruction of present pathogenic microorganisms and the increase of shelf life of foods. To achieve this process, the source of cobalt-60 and the electron accelerator can be used. The mechanically deboned chicken meat (MDCM) is used for the production of traditional meat products, and it may come to present pathogenic microorganisms such as staphylococcus aureus, a bacterium that produces enterotoxin, which causes food poisoning. The objective of this study is to analyze the effect of ionizing irradiation with different doses and dose rates, deriving from different radiation sources, on staphylococcal enterotoxin type B (SEB) in the MDCM. 50 g samples of MDCM were prepared in a batch of 6 kg of MDCM. The samples were contaminated, with the exception of the control, with SEB in amounts of about 100 ng. Then they were conditioned in a transparent bag made of low density polyethylene, frozen at -18±1 deg C overnight and irradiated in these conditions with doses of 0.0 kGy (control), 1.5 kGy and 3.0 kGy, and with three different dose rates, both in the Cobalt-60 and the electron accelerator. The experiments were conducted in quintuplicate. The SEB extraction from the MDCM was performed according to the protocol recommended by the manufacturer of the kit VIDAS Staph Enterotoxin II (bioMerrieux). The principle of mass balance was used to determine the actual amount of SEB removed by irradiation. The treatment that presented the best results was the one with a dose of 1.5 kGy, high dose rate of the electron accelerator. (author)

  11. Effect of different ionizing radiation doses and dose rates, using Cobalt-60 and electrons beam sources, on the staphylococcal enterotoxin inoculated in mechanically deboned chicken meat

    Energy Technology Data Exchange (ETDEWEB)

    Pomarico Neto, Walter; Brito, Poliana de Paula; Azevedo, Heliana de; Roque, Claudio Vitor; Fukuma, Henrique Takuji, E-mail: pbrito@cnen.gov.br, E-mail: hazevedo@cnen.gov.br, E-mail: cvroque@cnen.gov.br, E-mail: htfukuma@cnen.gov.br [Brazilian Nuclear Energy Commission (LAPOC/CNEN), Pocos de Caldas, MG (Brazil); Kodama, Yasko, E-mail: ykodama@ipen.br [Nuclear and Energy Research Institute (IPEN/CNEN-SP), Sao Paulo, SP (Brazil); Miya, Norma Terugo Nago; Pereira, Jose Luiz, E-mail: miya@fea.unicamp.br, E-mail: pereira@fea.unicamp.br [Campinas State University (UNICAMP), SP (Brazil). Dept. of Food Sciences

    2011-07-01

    The purpose of food irradiation is the destruction of present pathogenic microorganisms and the increase of shelf life of foods. To achieve this process, the source of cobalt-60 and the electron accelerator can be used. The mechanically deboned chicken meat (MDCM) is used for the production of traditional meat products, and it may come to present pathogenic microorganisms such as staphylococcus aureus, a bacterium that produces enterotoxin, which causes food poisoning. The objective of this study is to analyze the effect of ionizing irradiation with different doses and dose rates, deriving from different radiation sources, on staphylococcal enterotoxin type B (SEB) in the MDCM. 50 g samples of MDCM were prepared in a batch of 6 kg of MDCM. The samples were contaminated, with the exception of the control, with SEB in amounts of about 100 ng. Then they were conditioned in a transparent bag made of low density polyethylene, frozen at -18{+-}1 deg C overnight and irradiated in these conditions with doses of 0.0 kGy (control), 1.5 kGy and 3.0 kGy, and with three different dose rates, both in the Cobalt-60 and the electron accelerator. The experiments were conducted in quintuplicate. The SEB extraction from the MDCM was performed according to the protocol recommended by the manufacturer of the kit VIDAS Staph Enterotoxin II (bioMerrieux). The principle of mass balance was used to determine the actual amount of SEB removed by irradiation. The treatment that presented the best results was the one with a dose of 1.5 kGy, high dose rate of the electron accelerator. (author)

  12. Process and system to control manganese and cobalt isotopes deposits from the cooling fluid of a reactor

    International Nuclear Information System (INIS)

    Brehm, W.F.; McGuire, J.C.

    1978-01-01

    Process for controlling the deposition of manganese-54, cobalt-58 and cobalt-60 radionuclides on component surfaces, as from a liquid flow containing these nuclides and entering into contact with the surface of these components. It is characterised by the positioning of a getter forming substance in the liquid flow to collect these radionuclides on the getter forming substance which contains at least 73% nickel by weight [fr

  13. Cobalt adsorption/desorption on sediments from Piraquara de Fora bay, Angra dos Reis, Brazil

    International Nuclear Information System (INIS)

    Ferreira, Ingryd M.; Carvalho, Franciane M.; Ribeiro, Fernando C.A.; Martins, Nadia S.F.; Peres, Sueli S.; Lauria, Dejanira C.

    2015-01-01

    Among the radionuclides released with the liquid effluents from PWR power plants, cobalt isotopes ( 60 Co and 58 Co) play an important role for risk and environmental impact assessments. The laboratory experiments on radionuclide adsorption-desorption, followed by the use of adsorption isotherms are useful tools for prediction of transport, distribution, accumulation, and fate of a contaminant into a specific medium. Adsorption and desorption experiments were carried out in batches, using two sediment samples collected in Piraquara de Fora Bay, near the discharge channel of the liquid effluents from CNAAA. Aiming the assessment of the radioisotope adsorption mechanisms, sediment samples were shaken with solutions containing cobalt chloride which concentrations ranged between 10 -10 and 10 -3 M. In order to estimate the efficiency of adsorption, 100 Bq of 60 Co were used as radioactive tracer. The experimental data fitted well with Freundlich and Langmuir isotherms. Results point out a favorable and high cobalt adsorption on the sediments, although smaller than the ones reported in literature studies. Such smaller trend of adsorption coefficients may be caused by the low exchange capacity of the prevailing clay, kaolinite. The maximum adsorption capacities were found to be 10 and 17 moles/g for sediments in PT-01 and PT-02, respectively. Values lower than 8% of the adsorbed cobalt underwent desorption and this amount decreased to 4%, with time, which show the high retention capacity of these sediments. (author)

  14. Cobalt metabolism and toxicology-A brief update

    Energy Technology Data Exchange (ETDEWEB)

    Simonsen, Lars Ole, E-mail: LOSimonsen@dadlnet.dk; Harbak, Henrik; Bennekou, Poul

    2012-08-15

    Cobalt metabolism and toxicology are summarized. The biological functions of cobalt are updated in the light of recent understanding of cobalt interference with the sensing in almost all animal cells of oxygen deficiency (hypoxia). Cobalt (Co{sup 2+}) stabilizes the transcriptional activator hypoxia-inducible factor (HIF) and thus mimics hypoxia and stimulates erythropoietin (Epo) production, but probably also by the same mechanism induces a coordinated up-regulation of a number of adaptive responses to hypoxia, many with potential carcinogenic effects. This means on the other hand that cobalt (Co{sup 2+}) also may have beneficial effects under conditions of tissue hypoxia, and possibly can represent an alternative to hypoxic preconditioning. Cobalt is acutely toxic in larger doses, and in mammalian in vitro test systems cobalt ions and cobalt metal are cytotoxic and induce apoptosis and at higher concentrations necrosis with inflammatory response. Cobalt metal and salts are also genotoxic, mainly caused by oxidative DNA damage by reactive oxygen species, perhaps combined with inhibition of DNA repair. Of note, the evidence for carcinogenicity of cobalt metal and cobalt sulfate is considered sufficient in experimental animals, but is as yet considered inadequate in humans. Interestingly, some of the toxic effects of cobalt (Co{sup 2+}) have recently been proposed to be due to putative inhibition of Ca{sup 2+} entry and Ca{sup 2+}-signaling and competition with Ca{sup 2+} for intracellular Ca{sup 2+}-binding proteins. The tissue partitioning of cobalt (Co{sup 2+}) and its time-dependence after administration of a single dose have been studied in man, but mainly in laboratory animals. Cobalt is accumulated primarily in liver, kidney, pancreas, and heart, with the relative content in skeleton and skeletal muscle increasing with time after cobalt administration. In man the renal excretion is initially rapid but decreasing over the first days, followed by a second, slow

  15. Cobalt Fischer-Tropsch catalysts: influence of cobalt dispersion and titanium oxides promotion

    Energy Technology Data Exchange (ETDEWEB)

    Azib, H

    1996-04-10

    The aim of this work is to study the effect of Sol-Gel preparation parameters which occur in silica supported cobalt catalysts synthesis. These catalysts are particularly used for the waxes production in natural gas processing. The solids have been characterized by several techniques: transmission electron microscopy (TEM), X-ray absorption near edge spectroscopy (XANES), programmed temperature reduction (TPR), infrared spectroscopy (IR), ultraviolet spectroscopy (UV), Magnetism, thermodesorption of H{sub 2} (TPD). The results indicate that the control of the cobalt dispersion and oxide phases nature is possible by modifying Sol-Gel parameters. The catalytic tests in Fischer-Tropsch synthesis were conducted on a pilot unit under pressure (20 atm) and suggested that turnover rates were independent of Co crystallite size, Co phases in the solids (Co deg., cobalt silicate) and titanium oxide promotion. On the other methane, the C{sub 3}{sup +} hydrocarbon selectivity is increased with increasing crystallite size. Inversely, the methane production is favoured by very small crystallites, cobalt silicate increase and titanium addition. However, the latter, used as a cobalt promoter, has a benefic effect on the active phase stability during the synthesis. (author). 149 refs., 102 figs., 71 tabs.

  16. Postoperative radiotherapy in salivary ductal carcinoma: a single institution experience

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Tae Hyung; Kim, Mi Sun; Choi, Seo Hee; Suh, Yang Gun; Koh, Yoon Woo; Kim, Se Hun; Choi, Eun Chang; Keum, Ki Chang [Yonsei University College of Medicine, Seoul (Korea, Republic of)

    2014-09-15

    We reviewed treatment outcomes and prognostic factors for patients with salivary ductal carcinoma (SDC) treated with surgery and postoperative radiotherapy from 2005 to 2012. A total of 16 patients were identified and 15 eligible patients were included in analysis. Median age was 61 years (range, 40 to 71 years) and 12 patients (80%) were men. Twelve patients (80%) had a tumor in the parotid gland, 9 (60%) had T3 or T4 disease, and 9 (60%) had positive nodal disease. All patients underwent surgery and postoperative radiotherapy. Postoperative radiotherapy was delivered using 3-dimensional conformal radiotherapy or intensity-modulated radiotherapy. Locoregional failure-free survival (LRFFS), distant failure-free survival (DFFS), progression-free survival (PFS), and overall survival (OS) were calculated using the Kaplan-Meier method. Differences in survival based on risk factors were tested using a log-rank test. Median total radiotherapy dose was 60 Gy (range, 52.5 to 63.6 Gy). Four patients received concurrent weekly chemotherapy with cisplatin. Among 10 patients who underwent surgery with neck dissection, 7 received modified radical neck dissection. With a median follow-up time of 38 months (range, 24 to 105 months), 4-year rates were 86% for LRFFS, 51% for DFFS, 46% for PFS, and 93% for OS. Local failure was observed in 2 patients (13%), and distant failure was observed in 7 (47%). The lung was the most common involved site of distant metastasis. Surgery and postoperative radiotherapy in SDC patients resulted in good local control, but high distant metastasis remained a major challenge.

  17. Electroplated zinc-cobalt alloy

    International Nuclear Information System (INIS)

    Carpenter, D.E.O.S.; Farr, J.P.G.

    2005-01-01

    Recent work on the deposition and use of ectrodeposited zinc-cobalt alloys is surveyed. Alloys containing lower of Nuclear quantities of cobalt are potentially more useful. The structures of the deposits is related to their chemical and mechanical properties. The inclusion of oxide and its role in the deposition mechanism may be significant. Chemical and engineering properties relate to the metallurgical structure of the alloys, which derives from the mechanism of deposition. The inclusion of oxides and hydroxides in the electroplate may provide evidence for this mechanism. Electrochemical impedance measurements have been made at significant deposition potentials, in alkaline electrolytes. These reveal a complex electrode behaviour which depends not only on the electrode potential but on the Co content of the electrolyte. For the relevant range of cathodic potential zinc-cobalt alloy electrodeposition occurs through a stratified interface. The formation of an absorbed layer ZnOH/sup +/ is the initial step, this inhibits the deposition of cobalt at low cathodic potentials, so explaining its 'anomalous deposition'. A porous layer of zinc forms on the adsorbed ZnOH/sup +/ at underpotential. As the potential becomes more cathodic, cobalt co- deposits from its electrolytic complex forming a metallic solid solution of Co in Zn. In electrolytes containing a high concentration of cobalt a mixed entity (ZnCo)/sub +/ is assumed to adsorb at the cathode from which a CoZn intermetallic deposits. (author)

  18. Bioremediation of 60Co from simulated spent decontamination solutions

    International Nuclear Information System (INIS)

    Rashmi, K.; Naga Sowjanya, T.; Maruthi Mohan, P.; Balaji, V.; Venkateswaran, G.

    2004-01-01

    Bioremediation of 60 Co from simulated spent decontamination solutions by utilizing different biomass of (Neurospora crassa, Trichoderma viridae, Mucor recemosus, Rhizopus chinensis, Penicillium citrinum, Aspergillus niger and, Aspergillus flavus) fungi is reported. Various fungal species were screened to evaluate their potential for removing cobalt from very low concentrations (0.03-0.16 μM) in presence of a high background of iron (9.33 mM) and nickel (0.93 mM) complexed with EDTA (10.3 mM). The different fungal isolates employed in this study showed a pickup of cobalt in the range 8-500 ng/g of dry biomass. The [Fe]/[Co] and [Ni]/[Co] ratios in the solutions before and after exposure to the fungi were also determined. At micromolar level the cobalt pickup by many fungi especially the mutants of N. crassa is seen to be proportional to the initial cobalt concentration taken in the solution. However, R. chinensis exhibits a low but iron concentration dependent cobalt pickup. Prior saturating the fungi with excess of iron during their growth showed the presence of selective cobalt pickup sites. The existence of cobalt specific sorption sites is shown by a model experiment with R. chinensis wherein at a constant cobalt concentration (0.034 μM) and varying iron concentrations so as to yield [Fe/Co] initial ratios in solution of 10, 100, 1000 and 287 000 have all yielded a definite Co pickup capacity in the range 8-47 ng/g. The presence of Cr(III)EDTA (3 mM) in solution along with complexed Fe and Ni has not influenced the cobalt removal. The significant feature of this study is that even when cobalt is present in trace level (sub-micromolar) in a matrix of high concentration (millimolar levels) of iron, nickel and chromium, a situation typically encountered in spent decontamination solutions arising from stainless steel based primary systems of nuclear reactors, a number of fungi studied in this work showed a good sensitivity for cobalt pickup

  19. Radiation accident Hospital San Juan de Dios August - September 1996

    International Nuclear Information System (INIS)

    Chin Cheng, R.

    2000-01-01

    In Costa Rica, a radiation accident occurred in 1996. It took place at the Radiotherapy Service of the San Juan de Dios Hospital, which affected 115 patients. The Unit of Radiotherapy made a mistake in the calibration of the new bundle because of the change of external faeces of cobalt 60 (Alycon II). The work is a retrospective study that describes what happened in this accident, and the medical consequences that derived from it [es

  20. Cobalt allergy in hard metal workers

    Energy Technology Data Exchange (ETDEWEB)

    Fischer, T; Rystedt, I

    1983-03-01

    Hard metal contains about 10% cobalt. 853 hard metal workers were examined and patch tested with substances from their environment. Initial patch tests with 1% cobalt chloride showed 62 positive reactions. By means of secondary serial dilution tests, allergic reactions to cobalt were reproduced in 9 men and 30 women. Weak reactions could not normally be reproduced. A history of hand eczema was found in 36 of the 39 individuals with reproducible positive test reactions to cobalt, while 21 of 23 with a positive initial patch test but negative serial dilution test had never had any skin problems. Hand etching and hand grinding, mainly female activities and traumatic to the hands, were found to involve the greatest risk of cobalt sensitization. 24 individuals had an isolated cobalt allergy. They had probably been sensitized by hard metal work, while the individuals, all women, who had simultaneous nickel allergy had probably been sensitized to nickel before their employment and then became sensitized to cobalt by hard metal work. A traumatic occupation, which causes irritant contact dermatitis and/or a previous contact allergy or atopy is probably a prerequisite for the development of cobalt allergy.

  1. Dental plaque identification at home

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/article/003426.htm Dental plaque identification at home To use the sharing ... a sticky substance that collects around and between teeth. The home dental plaque identification test shows where ...

  2. Micro-analysis of plaque fluid from single-site fasted plaque

    International Nuclear Information System (INIS)

    Vogel, G.L.; Carey, C.M.; Chow, L.C.; Tatevossian, A.

    1990-01-01

    Despite the site-specific nature of caries, nearly all data on the concentration of ions relevant to the level of saturation of plaque fluid with respect to calcium phosphate minerals or enamel are from studies that used pooled samples. A procedure is described for the collection and analysis of inorganic ions relevant to these saturation levels in plaque fluid samples collected from a single surface on a single tooth. Various methods for examining data obtained by this procedure are described, and a mathematical procedure employing potential plots is recommended

  3. Pharmacokinetics of inorganic cobalt and a vitamin B12 supplement in the Thoroughbred horse: Differentiating cobalt abuse from supplementation.

    Science.gov (United States)

    Hillyer, L L; Ridd, Z; Fenwick, S; Hincks, P; Paine, S W

    2018-05-01

    While cobalt is an essential micronutrient for vitamin B 12 synthesis in the horse, at supraphysiological concentrations, it has been shown to enhance performance in human subjects and rats, and there is evidence that its administration in high doses to horses poses a welfare threat. Animal sport regulators currently control cobalt abuse via international race day thresholds, but this work was initiated to explore means of potentially adding to application of those thresholds since cobalt may be present in physiological concentrations. To devise a scientific basis for differentiation between presence of cobalt from bona fide supplementation and cobalt doping through the use of ratios. Six Thoroughbred horses were given 10 mL vitamin B 12 /cobalt supplement (Hemo-15 ® ; Vetoquinol, Buckingham, Buckinghamshire, UK., 1.5 mg B 12 , 7 mg cobalt gluconate = 983 μg total Co) as an i.v. bolus then an i.v. infusion (15 min) of 100 mg cobalt chloride (45.39 mg Co) 6 weeks later. Pre-and post-administration plasma and urine samples were analysed for cobalt and vitamin B 12 . Urine and plasma samples were analysed for vitamin B 12 using an immunoassay and cobalt concentrations were measured via ICP-MS. Baseline concentrations of cobalt in urine and plasma for each horse were subtracted from their cobalt concentrations post-administration for the PK analysis. Compartmental analysis was used for the determination of plasma PK parameters for cobalt using commercially available software. On administration of a vitamin B 12 /cobalt supplement, the ratio of cobalt to vitamin B 12 in plasma rapidly increased to approximately 3 and then rapidly declined below a ratio of 1 and then back to near baseline over the next week. On administration of 100 mg cobalt chloride, the ratio initially exceeded 10 in plasma and then declined with the lower 95% confidence interval remaining above a ratio of 1 for 7 days. For two horses with extended sampling, the plasma ratio remained above one for

  4. Treatment results of adjuvant radiotherapy and salvage radiotherapy after radical prostatectomy for prostate cancer

    International Nuclear Information System (INIS)

    Wadasaki, Koichi; Kaneyasu, Yuko; Kenjo, Masahiro; Matsuura, Kanji; Murakami, Yuji; Hashimoto, Yasutoshi; Ito, Katsuhide; Kiriu, Hiroshi; Ito, Atsushi

    2007-01-01

    The indications for and the efficacy of radiation therapy after radical operation for patients with prostate cancer are not clear. We analyzed the treatment results of adjuvant radiotherapy and salvage radiotherapy after radical prostatectomy. Between September 1997 and November 2004, 57 patients received adjuvant radiotherapy or salvage radiotherapy after radical prostatectomy. Fifteen patients received radiation therapy because of positive margins and/or extracapsular invasion in surgical specimens (adjuvant group). Forty-two patients received radiation therapy because of rising prostate-specific antigen (PSA) during follow-up (salvage group). Radiation therapy was delivered to the fossa of the prostate±seminal vesicles by a three-dimensional (3-D) conformal technique to a total dose of 60-66 Gy (median, 60 Gy). Biochemical control was defined as the maintenance of a PSA level of less than 0.2 ng/ml. The median follow-up period after radiation therapy was 33 months (range, 12-98 months). Three-year biochemical control rates were 87% for the adjuvant group and 61% for the salvage group. For patients in the salvage group treated without hormone therapy, the preradiation PSA value was the most significant factor for the biochemical control rate. The 3-year biochemical control rate was 93% in patients whose preradiation PSA was 0.5 ng/ml or less and 29% in patients whose preradiation PSA was more than 0.5 ng/ml. No severe adverse effects (equal to or more than grade 3) were seen in treated patients. Radiation therapy after radical prostatectomy seemed to be effective for adjuvant therapy and for salvage therapy in patients with a preradiation PSA of 0.5 ng/ml or less. Also, radiation to the fossa of the prostate±seminal vesicles, to a total dose of 60-66 Gy, using a three-dimensional (3-D) conformal technique, seemed to be safe. (author)

  5. COBALT SALTS PRODUCTION BY USING SOLVENT EXTRACTION

    Directory of Open Access Journals (Sweden)

    Liudmila V. Dyakova

    2010-06-01

    Full Text Available The paper deals with the extracting cobalt salts by using mixtures on the basis of tertiary amine from multicomponent solutions from the process of hydrochloride leaching of cobalt concentrate. The optimal composition for the extraction mixture, the relationship between the cobalt distribution coefficients and modifier’s nature and concentration, and the saltingout agent type have been determined. A hydrochloride extraction technology of cobalt concentrate yielding a purified concentrated cobalt solution for the production of pure cobalt salts has been developed and introduced at Severonikel combine.

  6. Calcium-assisted reduction of cobalt ferrite nanoparticles for nanostructured iron cobalt with enhanced magnetic performance

    International Nuclear Information System (INIS)

    Qi, B.; Andrew, J. S.; Arnold, D. P.

    2017-01-01

    This paper demonstrates the potential of a calcium-assisted reduction process for synthesizing fine-grain (~100 nm) metal alloys from metal oxide nanoparticles. To demonstrate the process, an iron cobalt alloy (Fe_6_6Co_3_4) is obtained by hydrogen annealing 7-nm cobalt ferrite (CoFe_2O_4) nanoparticles in the presence of calcium granules. The calcium serves as a strong reducing agent, promoting the phase transition from cobalt ferrite to a metallic iron cobalt alloy, while maintaining high crystallinity. Magnetic measurements demonstrate the annealing temperature is the dominant factor of tuning the grain size and magnetic properties. Annealing at 700 °C for 1 h maximizes the magnetic saturation, up to 2.4 T (235 emu/g), which matches that of bulk iron cobalt.

  7. Calcium-assisted reduction of cobalt ferrite nanoparticles for nanostructured iron cobalt with enhanced magnetic performance

    Energy Technology Data Exchange (ETDEWEB)

    Qi, B. [University of Florida, Interdisciplinary Microsystems Group, Department of Electrical and Computer Engineering (United States); Andrew, J. S. [University of Florida, Department of Materials Science and Engineering (United States); Arnold, D. P., E-mail: darnold@ufl.edu [University of Florida, Interdisciplinary Microsystems Group, Department of Electrical and Computer Engineering (United States)

    2017-03-15

    This paper demonstrates the potential of a calcium-assisted reduction process for synthesizing fine-grain (~100 nm) metal alloys from metal oxide nanoparticles. To demonstrate the process, an iron cobalt alloy (Fe{sub 66}Co{sub 34}) is obtained by hydrogen annealing 7-nm cobalt ferrite (CoFe{sub 2}O{sub 4}) nanoparticles in the presence of calcium granules. The calcium serves as a strong reducing agent, promoting the phase transition from cobalt ferrite to a metallic iron cobalt alloy, while maintaining high crystallinity. Magnetic measurements demonstrate the annealing temperature is the dominant factor of tuning the grain size and magnetic properties. Annealing at 700 °C for 1 h maximizes the magnetic saturation, up to 2.4 T (235 emu/g), which matches that of bulk iron cobalt.

  8. The Co{sup 60} Irradiation Facility and the Gamma Field at Riso; Appareil d'irradiation au cobalt-60 et champ sous irradiation gamma, a Riso; Ustanovka dlya obluchenij, rabotayushchaya na So60, i pole gamma-luchej v rizo; Instalacion de irradiacion con cobalto-60 y campo de irradiacion gamma en el centro de Riso

    Energy Technology Data Exchange (ETDEWEB)

    Brynjolfsson, A; Holm, N W [Danish Atomic Energy Commission, Establishment Riso (Denmark)

    1960-07-15

    The paper describes both the Co{sup 60} irradiation facility and the gamma field at the Agricultural Department of the Research Establishment, Riso. The Co{sup 60} irradiation facility contains 1,800 curies of Co{sup 60.} Details of the construction are given together with the safety precautions which have been included in the design. Dosimetry has been carried out by four different methods: 1. Ionisation chambers, 2. Calorimetry, 3. Fricke dosimeter, 4. Photographic films. A general outline is given of the gamma field, including details of source position. The dose rate is approximately 100 r./hr. at a distance of 1 m. An area of radius 15 m is used for the growing of plants under irradiation. A brief indication is given of the class of products which have been irradiated in the two facilities. (author) [French] Le memoire decrit l'appareil d'irradiation au cobalt-60 et le champ sous irradiation gamma du Departement de l'agriculture de l'Organisme de recherche de Riso. L'appareil d'irradiation au cobalt-60 contient une source de 1 800 curies. Des details sont donnes sur la construction ainsi que sur les dispositifs de protection compris dans le plan. Quatre methodes differentes ont ete utilisees pour la dosimetrie: 1. Chambres d'ionisation 2. Calorimetrie 3. Dosimetrie de Fricke 4. Pellicules photographique s On donne un apercu general du champ gamma, ainsi que des details sur la position de la source. L'intensite de dose est de 100 R/h environ a une distance de 1 m. Une zone d'un rayon de 15 m est utilisee pour la croissance des plantes soumises a l'irradiation. Des indications sommaires sont donnees sur la categorie des produits qui ont ete soumis a l'irradiation dans les deux installations. (author) [Spanish] Los autores describen la instalacion de irradiacion con cobalto-60 y el campo de irradiacion gamma del Departamento de Agronomia del Instituto de Investigaciones de Riso. El dispositivo de irradiacion consiste en una fuente de cobalto-60 de 1 800 curies

  9. Variables affecting viral plaque formation in microculture plaque assays using homologous antibody in a liquid overlay.

    Science.gov (United States)

    Randhawa, A S; Stanton, G J; Green, J A; Baron, S

    1977-05-01

    A liquid antibody microculture plaque assay and the variables that govern its effectiveness are described. The assay is based on the principle that low concentrations of homologous antibody can inhibit secondary plaque formation without inhibiting formation of primary plaques. Thus, clear plaques that followed a linear dose response were produced. The assay was found to be more rapid, less cumbersome, and less expensive than assays using agar overlays and larger tissue culture plates. It was reproducible, quantitative, and had about the same sensitivity as the agar overlay technique in measuring infectious coxsackievirus type B-3. It was more sensitive in assaying adenovirus type 3 and Western equine encephalomyelitis, vesicular stomatitis, Semliki forest, Sendai, Sindbis, and Newcastle disease viruses than were liquid, carboxymethylcellulose, and methylcellulose microculture plaque assays. The variables influencing sensitivity and accuracy, as determined by using coxsackievirus type B-3, were: (i) the inoculum volume of virus; (ii) the incubation period of virus; and (iii) the incubation temperature.

  10. The justification for the use of table of equivalent squares with respect to reference depth total scatter factor, and phantom scatter factor, for cobalt-60 teletherapy

    International Nuclear Information System (INIS)

    Afari, F.

    2011-01-01

    The use of equivalent squares is of great value and importance when determining output and depth dose data for rectangular fields. The variation with field shape of collimator scatter factors (S c ), phantom scatter factors (S c,p ) were studied using measurements on GWGP 80 cobalt - 60 teletherapy machine at the National Centre of Radiotherapy and Nuclear Medicine in the Korle-Bu Teaching Hospital. Measurements of the collimator scatter factors (S c ), phantom scatter factors (S p ) and total scatter factors (S c, p) were made at the depth of 5 cm, 10 cm, 15 cm and 20 cm in full scatter water phantom for square field side and rectangular fields of varying dimensions. The measurements were done using the source - axis distance (Sad) technique. The values of total scatter factor (S c,p ), phantom scatter factor and collimator scatter factor (S c ) obtained were used to estimate equivalent squares for the rectangular fields at the various depths. The equivalent squares were computed using the method of interpolation which is based on the scatter analysis of these scatter factors and these estimated equivalent squares were then compared with equivalent squares were then compared with equivalent square fields from BJR (supplement 21) tables of equivalent squares. The research revealed that there were average deviation of 1.5% for smaller rectangular field sizes and 8.8% for elongated rectangular field sizes between the estimated square field sizes and the equivalent square field from BJR (supplement 21) Table of equivalent square fields. The 8.8% for the elongated rectangular fields is not accepted, though such fields are rarely used in our Hospitals. It was found that the values of the equivalent square at the various depth were very consistent and do not vary with reference depth. These findings confirm that the clinical use of the BJR (supplement 21) Table of equivalent squares for total scatter factors and phantom scatter related quantities of rectangular fields is

  11. New dimensions in mechanical plaque control: An overview

    Directory of Open Access Journals (Sweden)

    Arnab Mandal

    2017-01-01

    Full Text Available Plaque control is the daily removal of dental plaque, oral biofilm and also prevention of their accumulation on the teeth and other parts of oral cavity. Dental plaque is the major etiology of maximum gingival and periodontal diseases. It is also related with various dental problems. Mechanical plaque control is a very effective method to get rid of plaque accumulation in oral cavity. In 3000 BC there was the first toothbrush invented by human beings. With time several modifications came in toothbrushes to make mechanical plaque control more effective in day to day oral hygiene practice. This article emphasizes on the advanced and emerging tools in mechanical plaque control methods in attaining an optimal level of oral hygiene standards and maintenance of oral health.

  12. Dosimetric Benefit of a New Ophthalmic Radiation Plaque

    Energy Technology Data Exchange (ETDEWEB)

    Marwaha, Gaurav, E-mail: marwahg2@ccf.org [Department of Radiation Oncology, Taussig Cancer Center, Cleveland Clinic Foundation, Cleveland, Ohio (United States); Cleveland Clinic Foundation, Cleveland, Ohio (United States); Wilkinson, Allan [Department of Radiation Oncology, Taussig Cancer Center, Cleveland Clinic Foundation, Cleveland, Ohio (United States); Cleveland Clinic Foundation, Cleveland, Ohio (United States); Bena, James [Department of Quantitative Health Sciences, Cleveland Clinic Foundation, Cleveland, Ohio (United States); Cleveland Clinic Foundation, Cleveland, Ohio (United States); Macklis, Roger [Department of Radiation Oncology, Taussig Cancer Center, Cleveland Clinic Foundation, Cleveland, Ohio (United States); Cleveland Clinic Foundation, Cleveland, Ohio (United States); Singh, Arun D. [Department of Radiation Oncology, Taussig Cancer Center, Cleveland Clinic Foundation, Cleveland, Ohio (United States); Department of Ophthalmic Oncology, Cole Eye Institute, Cleveland Clinic Foundation, Cleveland, Ohio (United States); Cleveland Clinic Foundation, Cleveland, Ohio (United States)

    2012-12-01

    Purpose: To determine whether the computed dosimetry of a new ophthalmic plaque, EP917, when compared with the standard Collaborative Ocular Melanoma Study (COMS) plaques, could reduce radiation exposure to vision critical structures of the eye. Methods and Materials: One hundred consecutive patients with uveal melanoma treated with COMS radiation plaques between 2007 and 2010 were included in this study. These treatment plans were generated with the use of Bebig Plaque Simulator treatment-planning software, both for COMS plaques and for EP917 plaques using I-125. Dose distributions were calculated for a prescription of 85 Gy to the tumor apex. Doses to the optic disc, opposite retina, lens, and macula were obtained, and differences between the 2 groups were analyzed by standard parametric methods. Results: When compared with the COMS plaques, the EP917 plaques used fewer radiation seeds by an average difference of 1.94 (P<.001; 95% confidence interval [CI], -2.8 to -1.06) and required less total strength of radiation sources by an average of 17.74 U (air kerma units) (P<.001; 95% CI, -20.16 to -15.32). The total radiation doses delivered to the optic disc, opposite retina, and macula were significantly less by 4.57 Gy, 0.50 Gy, and 11.18 Gy, respectively, with the EP917 plaques vs the COMS plaques. Conclusion: EP917 plaques deliver less overall radiation exposure to critical vision structures than COMS treatment plaques while still delivering the same total therapeutic dose to the tumor.

  13. Dosimetric Benefit of a New Ophthalmic Radiation Plaque

    International Nuclear Information System (INIS)

    Marwaha, Gaurav; Wilkinson, Allan; Bena, James; Macklis, Roger; Singh, Arun D.

    2012-01-01

    Purpose: To determine whether the computed dosimetry of a new ophthalmic plaque, EP917, when compared with the standard Collaborative Ocular Melanoma Study (COMS) plaques, could reduce radiation exposure to vision critical structures of the eye. Methods and Materials: One hundred consecutive patients with uveal melanoma treated with COMS radiation plaques between 2007 and 2010 were included in this study. These treatment plans were generated with the use of Bebig Plaque Simulator treatment-planning software, both for COMS plaques and for EP917 plaques using I-125. Dose distributions were calculated for a prescription of 85 Gy to the tumor apex. Doses to the optic disc, opposite retina, lens, and macula were obtained, and differences between the 2 groups were analyzed by standard parametric methods. Results: When compared with the COMS plaques, the EP917 plaques used fewer radiation seeds by an average difference of 1.94 (P<.001; 95% confidence interval [CI], −2.8 to −1.06) and required less total strength of radiation sources by an average of 17.74 U (air kerma units) (P<.001; 95% CI, −20.16 to −15.32). The total radiation doses delivered to the optic disc, opposite retina, and macula were significantly less by 4.57 Gy, 0.50 Gy, and 11.18 Gy, respectively, with the EP917 plaques vs the COMS plaques. Conclusion: EP917 plaques deliver less overall radiation exposure to critical vision structures than COMS treatment plaques while still delivering the same total therapeutic dose to the tumor.

  14. Association between epicardial fat volume and coronary plaques diagnosed by multislice computed tomography

    Directory of Open Access Journals (Sweden)

    José A. Morán Quijada

    2016-01-01

    Full Text Available Introduction: Coronary atherosclerotic disease is a major cause of death in Cuba and elsewhere. The volume of epicardial fat is considered a new cardiovascular risk factor because of its association with coronary atherogenesis.Objective: To determine, by multislice computed tomography, the association between epicardial fat volume and the presence of coronary atherosclerotic plaques.Method: A descriptive study was conducted with a universe of 130 patients with chest pain suggestive of ischemic heart disease, of which 117 were selected by opinion sampling. These patients underwent a calcium score study, a coronary angiography and a measurement of the epicardial fat volume.Results: Male patients predominated (54.7% and those aged 60-69 years (32.5%. A high volume of epicardial fat was found in 51.3% of patients, affecting 52.8% of women; 78.9% of patients with a calcium score between 100 and 399 UH had a high volume of epicardial fat, just as 71.2% of those with plaques and 100% of those with 4 or 5 plaques; 41% of patients had various types of plaque, which were mainly located in the anterior descending artery (88.1%.Conclusions: The measurement of the volume of epicardial fat is a useful tool to estimate the presence of coronary disease. When it was high, it was associated with older age, female gender and the presence of a higher calcium score, more plaques, more injuries and a greater involvement of the anterior descending artery.

  15. REVISS cobalt-60 production in Russia and beyond

    Science.gov (United States)

    Coppell, David; Latham, Ian; Nazarov, Michael

    2004-09-01

    Since Russian English Venture in Isotope Supply and Services (REVISS) Services is one of only two major global suppliers of sealed radiation sources to the industrial sterilization industry, security of supply of raw materials is understandably of primary concern to the users in the market place. This paper outlines the history, facilities and production capability of REVISS isotope suppliers, from MAYAK Production Association and Leningrad Nuclear Power Plant in Russia to Commission Nacional Energia Atomica in Argentina. The paper provides technical details of reactors and handling facilities used for fabrication of 60Co and 137Cs sources for industrial and research gamma irradiators and other applications. Other sources of 60Co in the world today will be reviewed briefly.

  16. Nickel acts as an adjuvant during cobalt sensitization

    DEFF Research Database (Denmark)

    Bonefeld, Charlotte Menne; Nielsen, Morten Milek; Vennegaard, Marie T.

    2015-01-01

    Metal allergy is the most frequent form of contact allergy with nickel and cobalt being the main culprits. Typically, exposure comes from metal-alloys where nickel and cobalt co-exist. Importantly, very little is known about how co-exposure to nickel and cobalt affects the immune system. We...... investigated these effects by using a recently developed mouse model. Mice were epicutaneously sensitized with i) nickel alone, ii) nickel in the presence of cobalt, iii) cobalt alone, or iv) cobalt in the presence of nickel, and then followed by challenge with either nickel or cobalt alone. We found...... that sensitization with nickel alone induced more local inflammation than cobalt alone as measured by increased ear-swelling. Furthermore, the presence of nickel during sensitization to cobalt led to a stronger challenge response to cobalt as seen by increased ear-swelling and increased B and T cell responses...

  17. Radiotherapy for the treatment of primary vaginal cancer

    International Nuclear Information System (INIS)

    Samant, Rajiv; Tam, Tiffany; Dahrouge, Simon; E, Choan

    2005-01-01

    Disease control rates and toxicity were evaluated among 28 primary vaginal cancer patients treated with curative intent using radiotherapy. At 5 years, the majority (60%) of patients were disease-free and local control was 73% when a combination of external beam radiotherapy and brachytherapy were used. Serious late toxicity was seen in 11% of patients

  18. Current diagnostic modalities for vulnerable plaque detection

    NARCIS (Netherlands)

    J.A. Schaar (Johannes); F. Mastik (Frits); E.S. Regar (Eveline); C.A. den Uil (Corstiaan); F.J.H. Gijsen (Frank); J.J. Wentzel (Jolanda); P.W.J.C. Serruys (Patrick); A.F.W. van der Steen (Ton)

    2007-01-01

    textabstractRupture of vulnerable plaques is the main cause of acute coronary syndrome and myocardial infarction. Identification of vulnerable plaques is therefore essential to enable the development of treatment modalities to stabilize such plaques. Several diagnostic methods are currently tested

  19. Hypofractionated passively scattered proton radiotherapy for low- and intermediate-risk prostate cancer is not associated with post-treatment testosterone suppression

    Energy Technology Data Exchange (ETDEWEB)

    Kil, Whoon Jong; Nichols, Romaine C. Jr. [Dept. of Radiation Oncology, Univ. of Florida, Gainesville (United States); Univ. of Florida Proton Therapy Inst., Jacksonville (United States)], e-mail: rnichols@floridaproton.org; And others

    2013-04-15

    Background: To investigate post-treatment changes in serum testosterone in low- and intermediate-risk prostate cancer patients treated with hypofractionated passively scattered proton radiotherapy. Material and methods: Between April 2008 and October 2011, 228 patients with low- and intermediate-risk prostate cancer were enrolled into an institutional review board-approved prospective protocol. Patients received doses ranging from 70 Cobalt Gray Equivalent (CGE) to 72.5 CGE at 2.5 CGE per fraction using passively scattered protons. Three patients were excluded for receiving androgen deprivation therapy (n = 2) or testosterone supplementation (n = 1) before radiation. Of the remaining 226 patients, pretreatment serum testosterone levels were available for 217. Of these patients, post-treatment serum testosterone levels were available for 207 in the final week of treatment, 165 at the six-month follow-up, and 116 at the 12-month follow-up. The post-treatment testosterone levels were compared with the pretreatment levels using Wilcoxon's signed-rank test for matched pairs. Results: The median pretreatment serum testosterone level was 367.7 ng/dl (12.8 nmol/l). The median changes in post-treatment testosterone value were as follows: +3.0 ng/dl (+0.1 nmol/l) at treatment completion; +6.0 ng/dl (+0.2 nmol/l) at six months after treatment; and +5.0 ng/dl (0.2 nmol/l) at 12 months after treatment. None of these changes were statistically significant. Conclusion: Patients with low- and intermediate-risk prostate cancer treated with hypofractionated passively scattered proton radiotherapy do not experience testosterone suppression. Our findings are consistent with physical measurements demonstrating that proton radiotherapy is associated with less scatter radiation exposure to tissues beyond the beam paths compared with intensity-modulated photon radiotherapy.

  20. Assessing caries, dental plaque and salivary flow in asthmatic adolescents using inhaled corticosteroids.

    Science.gov (United States)

    Santos, N C; Jamelli, S; Costa, L; Baracho Filho, C; Medeiros, D; Rizzo, J A; Sarinho, E

    2012-01-01

    A number of studies have reported that inhaled corticosteroids may cause a greater incidence of caries, reduced salivary flow, changes in saliva composition and an increased frequency of dental plaque, probably through alterations in the oral microbiota. The objective was to compare the frequency of caries, dental plaque and non-stimulated salivary flow rate among asthmatic adolescents using inhaled corticosteroids and non-asthmatic adolescents, as well as the salivary biochemical parameters (pH and leucocytes) in both groups. This research has a descriptive cross-sectional design to compare dental health of 40 asthmatics on inhaled corticosteroids and 40 non-asthmatic adolescents (median age 13 years). The findings were a higher number of tooth surfaces affected by dental caries (median 4 versus 1.5), and more dental plaques (median 70.5 versus 60.7) among asthmatic adolescents. They also had a significantly higher frequency of salivary leucocytes. The non-stimulated salivary flow was similar in both groups. The results suggest an association between the use of inhaled corticosteroids and an increased risk of dental caries and bacterial plaque, which calls for special attention of these patients by doctors and dental health professionals. Copyright © 2010 SEICAP. Published by Elsevier Espana. All rights reserved.

  1. Gene expression levels of matrix metalloproteinases in human atherosclerotic plaques and evaluation of radiolabeled inhibitors as imaging agents for plaque vulnerability

    International Nuclear Information System (INIS)

    Müller, Adrienne; Krämer, Stefanie D.; Meletta, Romana; Beck, Katharina; Selivanova, Svetlana V.; Rancic, Zoran; Kaufmann, Philipp A.; Vos, Bernhard; Meding, Jörg; Stellfeld, Timo; Heinrich, Tobias K.; Bauser, Marcus; Hütter, Joachim; Dinkelborg, Ludger M.; Schibli, Roger; Ametamey, Simon M.

    2014-01-01

    Introduction: Atherosclerotic plaque rupture is the primary cause for myocardial infarction and stroke. During plaque progression macrophages and mast cells secrete matrix-degrading proteolytic enzymes, such as matrix metalloproteinases (MMPs). We studied levels of MMPs and tissue inhibitor of metalloproteinases-3 (TIMP-3) in relation to the characteristics of carotid plaques. We evaluated in vitro two radiolabeled probes targeting active MMPs towards non-invasive imaging of rupture-prone plaques. Methods: Human carotid plaques obtained from endarterectomy were classified into stable and vulnerable by visual and histological analysis. MMP-1, MMP-2, MMP-8, MMP-9, MMP-10, MMP-12, MMP-14, TIMP-3, and CD68 levels were investigated by quantitative polymerase chain reaction. Immunohistochemistry was used to localize MMP-2 and MMP-9 with respect to CD68-expressing macrophages. Western blotting was applied to detect their active forms. A fluorine-18-labeled MMP-2/MMP-9 inhibitor and a tritiated selective MMP-9 inhibitor were evaluated by in vitro autoradiography as potential lead structures for non-invasive imaging. Results: Gene expression levels of all MMPs and CD68 were elevated in plaques. MMP-1, MMP-9, MMP-12 and MMP-14 were significantly higher in vulnerable than stable plaques. TIMP-3 expression was highest in stable and low in vulnerable plaques. Immunohistochemistry revealed intensive staining of MMP-9 in vulnerable plaques. Western blotting confirmed presence of the active form in plaque lysates. In vitro autoradiography showed binding of both inhibitors to stable and vulnerable plaques. Conclusions: MMPs differed in their expression patterns among plaque phenotypes, providing possible imaging targets. The two tested MMP-2/MMP-9 and MMP-9 inhibitors may be useful to detect atherosclerotic plaques, but not the vulnerable lesions selectively

  2. Effects of gamma radiation of Cobalt-60 on different phases of the evolutive cycle of pinworm - Tuta absoluta (Meyrich, 1917) (Lepidoptera,Gelechiidae); Efeitos da radiacao gama do Cobalto-60 nas diferentes fases do ciclo evolutivo da traca do tomateiro - Tuta absoluta (Meyrich, 1917) (Lepidoptera, Gelechiidae)

    Energy Technology Data Exchange (ETDEWEB)

    Groppo, Gerson Antonio

    1996-10-01

    The effects of different gamma radiation (Cobalt-60) doses on different phases of the evolutive cycle of Tuta absoluta (Meyrich, 1917) (Lepidoptera, Gelechiidae) have been studied under laboratory conditions in the laboratory of Entomology of Center for Nuclear Energy in Agriculture (CENA), University of Sao Paulo, Piracicaba, Sao Paulo State, Brazil. For all the treatments with gamma radiation a Cobalt-60 source type Gamma beam-650 was used. The doses utilized ranged from of 0,0 (Control) to 3250 Gy with a dose rate of 1110 Gy/h. The experiment was conducted under controlled conditions at 25{+-} 2 deg C, 70 {+-} 5% of relative humidity and photo period of (12:12). It was verified that the lethal doses were: for eggs - 70 Gy; for larvae - 200 Gy e for pupae - 300 Gy. The sterilizing dose for adults from irradiated larvae was 45 Gy. The sterilizing dose for the crossing of irradiated female with normal males (FI X MN) was 100 Gy and for normal female with irradiated male (FN x MI) was 150 Gy, in the both crosses, doses refer to irradiation of pupae. The sterilizing dose for adults, of both sexes, irradiated and crossed with normal adults, (FI x MN) and (FN x MI, were 150 and 200 Gy, respectively. The average longevity of adults, of both sexes, irradiated and crossed with normal adults was 8,3 days. The immediate lethal dose for adults was 3250 Gy. (author)

  3. Plaque Index in Multi-Bracket Fixed Appliances

    International Nuclear Information System (INIS)

    Rahim, Z.H.; Shaikh, S.; Razak, F.A.

    2014-01-01

    To compare the plaque index in patients receiving multi-bracket fixed orthodontic treatment for various factors like age, gender, socio-economic status, brushing practices, meal habits, types of brackets, types of ligations, use of mouthwash and duration of treatment. Study Design: Cross-sectional analytical study. Place and Duration of Study: Orthodontics Clinic, The Aga Khan University Hospital, from September to November 2011. Methodology: Socio-demographic and clinical modalities were defined and recorded for 131 patients having multi-bracket fixed appliances. The plaque index of subjects were recorded according to the Silness and Loe plaque index method. Independent sample t-test was used to see difference in plaque index in factors having two variables. One way ANOVA and Post-Hoc Tukey tests were used to see difference in plaque index in factors having three variables. Kappa statistics was used to assess inter examiner reliability. P-value 0.05 was taken to be significant. Results: The sample comprised of 37% males (n = 48) and 63% females (n = 83). The plaque index had statistically significant association with practice of brushing i.e., timing of brushing (p=0.001), method of brushing (p=0.08), type of ligatures (p=0.05) and frequency of visits (p=0.01). Conclusion: The plaque accumulation is significantly decreased in subjects who brush the teeth twice or more than twice a day and those who brush their teeth after breakfast. The use of interdental brush and stainless steel ligatures had significantly low plaque. Subjects presenting with more frequent appointments of short-period had significantly less plaque. (author)

  4. Radiotherapy for ocular lesions by electron beam therapy

    International Nuclear Information System (INIS)

    Miyaishi, Kazuo

    1981-01-01

    Radiotherapy can be very significant as the treatment for ocular lesions, eyes need to be preserved as properly as possible on their functions and cosmetics. The appliance of conventional X ray therapy has been gradually abandaned as conventional X ray therapy ceased to be accepted as the general treatment for malignant tumors. Consequently the necessity of electron beam therapy has been rising even as the substituted method for conventional X ray therapy. The department of radiology of Gunma University was obliged to establish a new therapy for ocular lesions, and has been trying electron beam therapy since 1973; It is concluded that electron beam therapy is not at all inferior to conventional X ray therapy as reported above. Basic therapeutic methods for ocular lesions are the following: 1) For epidermoid carcinoma, 600 rads at a time, 3600 - 4200 rads in total is applied by 8 MeV electron twice a week method. 2) For malignant melanoma, 1000 rads at a time, 4000 - 5000 rads in total is applied by 8 MeV electron twice a week method. 3) For orbitar lymphoid neoplasm, Cobalt-60 γ ray or Linac X ray is applied together with electron beam. 4) For embryonal rhabdomyosarcoma, adenoid cystic cancer etc., the therapy for whole body is necessary. 5) For benign tumors, a small dose at a time is applied for a long time. (author)

  5. PLAQUE ASSAY OF NEWCASTLE DISEASE VIRUS

    Directory of Open Access Journals (Sweden)

    B. Sardjono

    2012-09-01

    Full Text Available The Newcastle disease virus (NDV was isolated from a 3 months-old indigenous chicken (buras or kampung chicken which showed clinical signs of Newcastle disease (ND. For viral isolation a small part of the spleen and lung were inoculated into 10 days-old embryonated chicken eggs. The physical characteristics of the isolate (A/120 were studied. The hemagglutination of chicken red blood cell showed slow elution, thermostability of hemagglutinin at 56°C was 120 minutes. The vims was able to agglutinate horse erythrocytes but not those of sheep. The biological characteristics on mean death time (MDT of embryonated chicken egg and plaque morphology on chicken embryo fibroblast (CEF primary cell cultures were studied. The MDT was 56 hours, the isolate was velogenic NDV. There were three different plaque morphologies on CEF : 2 mm clear plaques, 1 mm clear plaques, and minute clear plaques which were visible only with microscopic examination.

  6. Nonrandomized study comparing the effects of preoperative radiotherapy and daily administration of low-dose cisplatin with those radiotherapy alone for oral cancer

    International Nuclear Information System (INIS)

    Kurita, Hiroshi; Azegami, Takuya; Kobayashi, Hirokazu; Kurashina, Kenji; Tanaka, Kouichi; Kotani, Akira; Oguchi, Masahiko; Tamura, Minoru.

    1997-01-01

    The purpose of this study was to compare the effect of preoperative radiotherapy and daily administration of low-dose cisplatin with those of radiotherapy alone for oral cancer. Ten patients underwent preoperative radiotherapy of 30 to 40 Gy with concomitant daily administration of low-dose cisplatin (5 mg/body or 5 mg/m 2 ). Ten patients received external radiotherapy alone. The locoregional response rates (complete response and partial response) did not differ significantly between the two groups (80% for combined therapy and 60% for radiotherapy alone). On histopathologic evaluation of surgical specimens, however, the combined-therapy group (80%) had a higher response rate than did the radiotherapy-alone group (10%; p<0.01). We conclude that daily administration of low-dose cisplatin enhances the efficacy of radiotherapy against primary tumors. We also suggested that combined therapy may be beneficial as an initial treatment for oral cancer before a planned operation. (author)

  7. Intensity-Modulated Radiotherapy for Sinonasal Cancer: Improved Outcome Compared to Conventional Radiotherapy

    International Nuclear Information System (INIS)

    Dirix, Piet; Vanstraelen, Bianca; Jorissen, Mark; Vander Poorten, Vincent; Nuyts, Sandra

    2010-01-01

    Purpose: To evaluate clinical outcome and toxicity of postoperative intensity-modulated radiotherapy (IMRT) for malignancies of the nasal cavity and paranasal sinuses. Methods and Materials: Between 2003 and 2008, 40 patients with cancer of the paranasal sinuses (n = 34) or nasal cavity (n = 6) received postoperative IMRT to a dose of 60 Gy (n = 21) or 66 Gy (n = 19). Treatment outcome and toxicity were retrospectively compared with that of a previous patient group (n = 41) who were also postoperatively treated to the same doses but with three-dimensional conformal radiotherapy without intensity modulation, from 1992 to 2002. Results: Median follow-up was 30 months (range, 4-74 months). Two-year local control, overall survival, and disease-free survival were 76%, 89%, and 72%, respectively. Compared to the three-dimensional conformal radiotherapy treatment, IMRT resulted in significantly improved disease-free survival (60% vs. 72%; p = 0.02). No grade 3 or 4 toxicity was reported in the IMRT group, either acute or chronic. The use of IMRT significantly reduced the incidence of acute as well as late side effects, especially regarding skin toxicity, mucositis, xerostomia, and dry-eye syndrome. Conclusions: Postoperative IMRT for sinonasal cancer significantly improves disease-free survival and reduces acute as well as late toxicity. Consequently, IMRT should be considered the standard treatment modality for malignancies of the nasal cavity and paranasal sinuses.

  8. Bioremediation of {sup 60}Co from simulated spent decontamination solutions

    Energy Technology Data Exchange (ETDEWEB)

    Rashmi, K.; Naga Sowjanya, T.; Maruthi Mohan, P.; Balaji, V.; Venkateswaran, G

    2004-07-26

    Bioremediation of {sup 60}Co from simulated spent decontamination solutions by utilizing different biomass of (Neurospora crassa, Trichoderma viridae, Mucor recemosus, Rhizopus chinensis, Penicillium citrinum, Aspergillus niger and, Aspergillus flavus) fungi is reported. Various fungal species were screened to evaluate their potential for removing cobalt from very low concentrations (0.03-0.16 {mu}M) in presence of a high background of iron (9.33 mM) and nickel (0.93 mM) complexed with EDTA (10.3 mM). The different fungal isolates employed in this study showed a pickup of cobalt in the range 8-500 ng/g of dry biomass. The [Fe]/[Co] and [Ni]/[Co] ratios in the solutions before and after exposure to the fungi were also determined. At micromolar level the cobalt pickup by many fungi especially the mutants of N. crassa is seen to be proportional to the initial cobalt concentration taken in the solution. However, R. chinensis exhibits a low but iron concentration dependent cobalt pickup. Prior saturating the fungi with excess of iron during their growth showed the presence of selective cobalt pickup sites. The existence of cobalt specific sorption sites is shown by a model experiment with R. chinensis wherein at a constant cobalt concentration (0.034 {mu}M) and varying iron concentrations so as to yield [Fe/Co]{sub initial} ratios in solution of 10, 100, 1000 and 287 000 have all yielded a definite Co pickup capacity in the range 8-47 ng/g. The presence of Cr(III)EDTA (3 mM) in solution along with complexed Fe and Ni has not influenced the cobalt removal. The significant feature of this study is that even when cobalt is present in trace level (sub-micromolar) in a matrix of high concentration (millimolar levels) of iron, nickel and chromium, a situation typically encountered in spent decontamination solutions arising from stainless steel based primary systems of nuclear reactors, a number of fungi studied in this work showed a good sensitivity for cobalt pickup.

  9. Cobalt-60 total body irradiation dosimetry at 220 cm source-axis distance

    International Nuclear Information System (INIS)

    Glasgow, G.P.; Mill, W.B.

    1980-01-01

    Adults with acute leukemia are treated with cyclophosphamide and total body irradiation (TBI) followed by autologous marrow transplants. For TBI, patients seated in a stand angled 45 0 above the floor are treated for about 2 hours at 220 cm source-axis distance (SAD) with sequential right and left lateral 87 cm x 87 cm fields to a 900 rad mid-pelvic dose at about 8 rad/min using a 5000 Ci cobalt unit. Maximum (lateral) to minimum (mid-plane) dose ratios are: hips--1.15, shoulders--1.30, and head--1.05, which is shielded by a compensator filter. Organ doses are small intestine, liver and kidneys--1100 rad, lung--1100 to 1200 rad, and heart--1300 rad. Verification dosimetry reveals the prescribed dose is delivered to within +-5%. Details of the dosimetry of this treatment are presented

  10. MR plaque imaging of the carotid artery

    International Nuclear Information System (INIS)

    Watanabe, Yuji; Nagayama, Masako

    2010-01-01

    Atherosclerotic carotid plaque represents a major cause of cerebral ischemia. The detection of vulnerable plaque is important for preventing future cardiovascular events. The key factors in advanced plaque that are most likely to lead to patient complications are the condition of the fibrous cap, the size of the necrotic core and hemorrhage, and the extent of inflammatory activity within the plaque. Magnetic resonance (MR) imaging has excellent soft tissue contrast and can allow for a more accurate and objective estimation of carotid wall morphology and plaque composition. Recent advances in MR imaging techniques have permitted serial monitoring of atherosclerotic disease evolution and the identification of intraplaque risk factors for accelerated progression. The purpose of this review article is to review the current state of techniques of carotid wall MR imaging and the characterization of plaque components and surface morphology with MR imaging, and to describe the clinical practice of carotid wall MR imaging for the determination of treatment plan. (orig.)

  11. Autonomous monitoring unit, signs and registration for Cobalt-60 irradiator safety system

    Energy Technology Data Exchange (ETDEWEB)

    Baldaconi, Ricardo H.; Costa, Fabio E. da, E-mail: ricardohovacker@hotmail.com, E-mail: fecosta@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2015-07-01

    The Cobalt-60 irradiator of IPEN / CNEN, a category IV facility, has a security system for inter locking doors or exposure of radioactive sources made simultaneously by a programmable logic controller (PLC) model S7- 200 from Siemens and a relay logic. From a set of information, the both systems work together opening doors or exposing the sources. All incoming and outgoing information are sent serially via EIA232 communication to a personal computer with Windows® platform for a supervisory program which provides besides a monitoring the entire process by a synoptic table on the computer screen, also keeps records of all events on the computer's hard drive. The electronic management has proven to be efficient and has not produced any failure that had compromised the safety. The PLC along with the relay logic has always taken the right decisions ensuring proper radiation protection of operators and the integrity of radioactive sources, but it presented over the years of operation (beginning in 2004) less than a dozen flaws in system event log. The deficiency was found between the process of sending events via serial communication (EIA232) to the supervisory program. When failure occurs in a very short time, the PLC always took the right decision, but the registration process that had to go through the Windows® timeshare lost the information. This work aimed to build a standalone electronics connect the inputs and outputs of the security system, fully optocoupled to avoid any interference to the security system. It records each event on a memory card, waits for the right decision of the security system and in case of an incorrect decision an independent alarm notifies its own synoptic picture, and sends a text message to a group of defined cell phones. The circuit uses two microcontrollers called 'main' and 'secondary'. The main is responsible for the control and monitoring of peripheral inputs and outputs of the security system. The main is

  12. Autonomous monitoring unit, signs and registration for Cobalt-60 irradiator safety system

    International Nuclear Information System (INIS)

    Baldaconi, Ricardo H.; Costa, Fabio E. da

    2015-01-01

    The Cobalt-60 irradiator of IPEN / CNEN, a category IV facility, has a security system for inter locking doors or exposure of radioactive sources made simultaneously by a programmable logic controller (PLC) model S7- 200 from Siemens and a relay logic. From a set of information, the both systems work together opening doors or exposing the sources. All incoming and outgoing information are sent serially via EIA232 communication to a personal computer with Windows® platform for a supervisory program which provides besides a monitoring the entire process by a synoptic table on the computer screen, also keeps records of all events on the computer's hard drive. The electronic management has proven to be efficient and has not produced any failure that had compromised the safety. The PLC along with the relay logic has always taken the right decisions ensuring proper radiation protection of operators and the integrity of radioactive sources, but it presented over the years of operation (beginning in 2004) less than a dozen flaws in system event log. The deficiency was found between the process of sending events via serial communication (EIA232) to the supervisory program. When failure occurs in a very short time, the PLC always took the right decision, but the registration process that had to go through the Windows® timeshare lost the information. This work aimed to build a standalone electronics connect the inputs and outputs of the security system, fully optocoupled to avoid any interference to the security system. It records each event on a memory card, waits for the right decision of the security system and in case of an incorrect decision an independent alarm notifies its own synoptic picture, and sends a text message to a group of defined cell phones. The circuit uses two microcontrollers called 'main' and 'secondary'. The main is responsible for the control and monitoring of peripheral inputs and outputs of the security system. The main is

  13. Cytogenetic characterization of low-dose hyper-radiosensitivity in Cobalt-60 irradiated human lymphoblastoid cells

    Energy Technology Data Exchange (ETDEWEB)

    Joshi, Gnanada S. [Department of Biological Sciences, Wayne State University, Detroit, MI 48202 (United States); Joiner, Michael C. [Department of Radiation Oncology, Wayne State University, Detroit, MI 48201 (United States); Tucker, James D., E-mail: jtucker@biology.biosci.wayne.edu [Department of Biological Sciences, Wayne State University, Detroit, MI 48202 (United States)

    2014-12-15

    Highlights: • Human cells were irradiated in G1 or G2 and evaluated for micronuclei and bridges. • Cells irradiated in G2 but not in G1 exhibit low dose hyper-radiosensitivity. • Response curves of cells irradiated in G2 do not fit a linear-no-threshold model. • Response curves of cells irradiated in G1 fit a linear-no-threshold model. - Abstract: The dose-effect relationships of cells exposed to ionizing radiation are frequently described by linear quadratic (LQ) models over an extended dose range. However, many mammalian cell lines, when acutely irradiated in G2 at doses ≤0.3 Gy, show hyper-radiosensitivity (HRS) as measured by reduced clonogenic cell survival, thereby indicating greater cell lethality than is predicted by extrapolation from high-dose responses. We therefore hypothesized that the cytogenetic response in G2 cells to low doses would also be steeper than predicted by LQ extrapolation from high doses. We tested our hypothesis by exposing four normal human lymphoblastoid cell lines to 0–400 cGy of Cobalt-60 gamma radiation. The cytokinesis block micronucleus assay was used to determine the frequencies of micronuclei and nucleoplasmic bridges. To characterize the dependence of the cytogenetic damage on dose, univariate and multivariate regression analyses were used to compare the responses in the low- (HRS) and high-dose response regions. Our data indicate that the slope of the response for all four cell lines at ≤20 cGy during G2 is greater than predicted by an LQ extrapolation from the high-dose responses for both micronuclei and bridges. These results suggest that the biological consequences of low-dose exposures could be underestimated and may not provide accurate risk assessments following such exposures.

  14. Electrocatalytic performance evaluation of cobalt hydroxide and cobalt oxide thin films for oxygen evolution reaction

    Science.gov (United States)

    Babar, P. T.; Lokhande, A. C.; Pawar, B. S.; Gang, M. G.; Jo, Eunjin; Go, Changsik; Suryawanshi, M. P.; Pawar, S. M.; Kim, Jin Hyeok

    2018-01-01

    The development of an inexpensive, stable, and highly active electrocatalyst for oxygen evolution reaction (OER) is essential for the practical application of water splitting. Herein, we have synthesized an electrodeposited cobalt hydroxide on nickel foam and subsequently annealed in an air atmosphere at 400 °C for 2 h. In-depth characterization of all the films using X-ray diffraction (XRD), X-ray photoelectron emission spectroscopy (XPS), field emission scanning electron microscopy (FE-SEM), electrochemical impedance spectroscopy (EIS) and linear sweep voltammetry (LSV) techniques, which reveals major changes for their structural, morphological, compositional and electrochemical properties, respectively. The cobalt hydroxide nanosheet film shows high catalytic activity with 290 mV overpotential at 10 mA cm-2 and 91 mV dec-1 Tafel slope and robust stability (24 h) for OER in 1 M KOH electrolyte compared to cobalt oxide (340 mV). The better OER activity of cobalt hydroxide in comparison to cobalt oxide originated from high active sites, enhanced surface, and charge transport capability.

  15. Non-randomized therapy trial to determine the safety and efficacy of heavy ion radiotherapy in patients with non-resectable osteosarcoma

    Directory of Open Access Journals (Sweden)

    Bischof Marc

    2010-03-01

    Full Text Available Abstract Background Osteosarcoma is the most common primary malignant bone tumor in children and adolescents. For effective treatment, local control of the tumor is absolutely critical, because the chances of long term survival are EURAMOS1. Local photon radiotherapy has previously been used in small series and in an uncontrolled, highly individualized fashion, which, however, documented that high dose radiotherapy can, in principle, be used to achieve local control. Generally the radiation dose that is necessary for a curative approach can hardly be achieved with conventional photon radiotherapy in patients with non-resectable tumors that are usually located near radiosensitive critical organs such as the brain, the spine or the pelvis. In these cases particle Radiotherapy (proton therapy (PT/heavy ion therapy (HIT may offer a promising new alternative. Moreover, compared with photons, heavy ion beams provide a higher physical selectivity because of their finite depth coverage in tissue. They achieve a higher relative biological effectiveness. Phase I/II dose escalation studies of HIT in adults with non-resectable bone and soft tissue sarcomas have already shown favorable results. Methods/Design This is a monocenter, single-arm study for patients ≥ 6 years of age with non-resectable osteosarcoma. Desired target dose is 60-66 Cobalt Gray Equivalent (Gy E with 45 Gy PT (proton therapy and a carbon ion boost of 15-21 GyE. Weekly fractionation of 5-6 × 3 Gy E is used. PT/HIT will be administered exclusively at the Ion Radiotherapy Center in Heidelberg. Furthermore, FDG-PET imaging characteristics of non-resectable osteosarcoma before and after PT/HIT will be investigated prospectively. Systemic disease before and after PT/HIT is targeted by standard chemotherapy protocols and is not part of this trial. Discussion The primary objectives of this trial are the determination of feasibility and toxicity of HIT. Secondary objectives are tumor response

  16. Young age under 60 years is not a contraindication to treatment with definitive dose escalated radiotherapy for prostate cancer

    International Nuclear Information System (INIS)

    Klayton, Tracy L.; Ruth, Karen; Horwitz, Eric M.; Uzzo, Robert G.; Kutikov, Alexander; Chen, David Y.T.; Sobczak, Mark; Buyyounouski, Mark K.

    2011-01-01

    Background: It is widely believed that younger prostate cancer patients are at greater risk of recurrence following radiotherapy (RT). Methods: From 1992 to 2007, 2168 (395 age ⩽60) men received conformal RT alone for prostate cancer at our institution (median dose = 76 Gy, range: 72–80). Multivariable analysis (MVA) was used to identify significant predictors for BF and PCSM. Cumulative incidence was estimated using the competing risk method (Fine and Gray) for BF (Phoenix definition) and PCSM to account for the competing risk of death. Results: With a median follow-up of 72.2 months (range: 24.0–205.1), 8-year BF was 27.1% for age ⩽60 vs. 23.7% for age >60 (p = 0.29). Eight-year PCSM was 3.0% for age ⩽60 vs. 2.0% for age >60 (p = 0.52). MVA for BF identified initial PSA [adjusted HR = 1.7 (PSA 10–20), 2.6 (PSA >20), p 12 months), p < 0.01] as significant, but not age or ADT <12 months. MVA for PCSM identified Gleason score [adjusted HR = 3.0 (G8–10), p = 0.01] and T-stage [adjusted HR = 8.7 (T3-4), p < 0.01] as significant, but not age, PSA, or ADT. Conclusion: This is the largest, most mature study of younger men treated with RT for prostate cancer that confirms young age is not prognostic for BF.

  17. Cobalt sensitization and dermatitis

    DEFF Research Database (Denmark)

    Thyssen, Jacob P

    2012-01-01

    : This clinical review article presents clinical and scientific data on cobalt sensitization and dermatitis. It is concluded that cobalt despite being a strong sensitizer and a prevalent contact allergen to come up on patch testing should be regarded as a very complex metal to test with. Exposure...

  18. Lethal dose determination of Cobalt-60 for adult Tribolium castaneum (Coleoptera: Tenebrionidae) and Cryptolestes ferrugineus (Coleoptera: Laemophloeidae)

    Energy Technology Data Exchange (ETDEWEB)

    Farias, Anderson Aparecido, E-mail: potenza@biologico.sp.gov.br [Instituto Biologico, Centro de Pesquisa e Desenvolvimento de Protecao Ambiental, Sao Paulo, SP (Brazil); Potenza, Marcos Roberto, E-mail: fcreis@usp.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil); Reis, Fabricio Caldeira; Sato, Mario Eidi, E-mail: mesato@biologico.sp.gov.br [Instituto Biologico, Centro Experimental Central, Laboratorio de Acarologia, Campinas, SP (Brazil)

    2015-07-01

    The insect infestation is a major problem in the grain storage. The pesticides are most widely used method for disinfestation and prevention. Treatment with gamma irradiation may increase the product shelf life without encountering formation of waste can be used in packaged foods and ready for commercialization, representing an important alternative to the use of pesticides. This study aimed to determine the immediate lethal dose of gamma radiation for adults of Tribolium castaneum and Cryptolestes ferrugineus. The study was conducted in the Instituto Biologico and the radiations held at the Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN, Sao Paulo city, using a multipurpose irradiator Cobalt-60 with 3.31 dose rate and 3.23 kGy in months of November/2014 and January/2015. Each experimental unit consisted of 20 adult insects, confined in a 10 mL polyethylene container. The experimental plots in number 10 per dose were subjected to increasing doses of gamma radiation: 0; 0.5; 0.75; 1.0; 1.25; 1.50; 1.75; 2.00; 2:50 and 3.00 kGy. Mortality was assessed within two to four hours after irradiation. The data were submitted to Probit analysis, using the POLO PLUS program. The LD90 to control 90% (LD90) to control adult Cryptolestes ferrugineus and Tribolium castaneum were 2.73 and 2.91 kGy, respectively. (author)

  19. Lethal dose determination of Cobalt-60 for adult Tribolium castaneum (Coleoptera: Tenebrionidae) and Cryptolestes ferrugineus (Coleoptera: Laemophloeidae)

    International Nuclear Information System (INIS)

    Farias, Anderson Aparecido; Potenza, Marcos Roberto; Reis, Fabricio Caldeira; Sato, Mario Eidi

    2015-01-01

    The insect infestation is a major problem in the grain storage. The pesticides are most widely used method for disinfestation and prevention. Treatment with gamma irradiation may increase the product shelf life without encountering formation of waste can be used in packaged foods and ready for commercialization, representing an important alternative to the use of pesticides. This study aimed to determine the immediate lethal dose of gamma radiation for adults of Tribolium castaneum and Cryptolestes ferrugineus. The study was conducted in the Instituto Biologico and the radiations held at the Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN, Sao Paulo city, using a multipurpose irradiator Cobalt-60 with 3.31 dose rate and 3.23 kGy in months of November/2014 and January/2015. Each experimental unit consisted of 20 adult insects, confined in a 10 mL polyethylene container. The experimental plots in number 10 per dose were subjected to increasing doses of gamma radiation: 0; 0.5; 0.75; 1.0; 1.25; 1.50; 1.75; 2.00; 2:50 and 3.00 kGy. Mortality was assessed within two to four hours after irradiation. The data were submitted to Probit analysis, using the POLO PLUS program. The LD90 to control 90% (LD90) to control adult Cryptolestes ferrugineus and Tribolium castaneum were 2.73 and 2.91 kGy, respectively. (author)

  20. Results of radiotherapy with and without chemotherapy for esophageal cancer

    International Nuclear Information System (INIS)

    Hada, Yoshihiro

    1986-01-01

    From 1975 to 1983, a total of 51 cases of esophageal cancer with T2 ∼ T3 in TNM classification, were treated by radiotherapy alone or combined chemotherapy. All 51 patients received total dose of 60 ∼ 70 GY for 6 ∼ 8 weeks and 20 out of 51 were treated by radiotherapy plus chemotherapy (5FU or UFT and/or bleomycin or pepleomycin). The 2-year-survival rate was slightly better in patients treated by radiotherapy plus chemotherapy than in patients treated by radiotherapy alone, but this difference was not significant. (author)

  1. Determination of Absorbed Dose in Large 60-Co Fields Radiotherapy

    International Nuclear Information System (INIS)

    Hrsak, H.

    2003-01-01

    Radiation in radiotherapy has selective impact on ill and healthy tissue. During the therapy the healthy tissue receives certain amount of dose. Therefore dose calculations in outer radiotherapy must be accurate because too high doses produce damage in healthy tissue and too low doses cannot ensure efficient treatment of cancer cells. A requirement on accuracy in the dose calculations has lead to improvement of detectors, and development of absolute and relative dosimetry. Determination of the dose distribution with use of computer is based on data provided by the relative dosimetry. This paper compares the percentage depth doses in cubic water phantoms of various dimensions with percentage depth doses calculated with use of Mayneord factor from the experimental depth doses measured in water phantom of large dimension. Depth doses in water phantoms were calculated by the model of empirical dosimetrical functions. The calculations were based on the assumption that large 6 0C o photon field exceeds the phantom's limits. The experimental basis for dose calculations by the model of empirical dosimetrical functions were exposure doses measured in air and dose reduction factors because of finite phantom dimensions. Calculations were performed by fortran 90 software. It was found that the deviation of dosimetric model was small in comparison to the experimental data. (author)

  2. The behaviour of cesium 137, chromium 51, cobalt 60, Manganese 54, sodium 22 and zinc 65 in simulated estuarine environments. Effects of suspended mineral particles and dissolved organic matters

    International Nuclear Information System (INIS)

    Mahler, P.

    1985-09-01

    This laboratory investigation studied the retention of 6 radionuclides (cesium 137, chrome 51, cobalt 60, manganese 54, sodium 22 and zinc 65) on three types of clay particles (kaolinite, illite, montmorillonite) and on sediments, suspended in media with salinities ranging between 0 and 34 per mill, with or without organic matters. Measurement of the radioactivity retained by the particles after 5 days' contact with the radionuclide made it possible to calculate the percentages retained and the distribution coefficients, and to follow their evolution versus salinity. Parallel experiments studied the behaviours of the 6 radionuclides as a function of experimental factors (wall effect, contact time..). An exhaustive bibliographic review gives the state-of-the-art of the knowledge. The following conclusions were derived: - the retention of all the radionuclides but chromium 51 decreased as soon as a low salinity appeared. Chromium (available as Cr 3+ ) precipitated quickly and strongly during fixation whatever the surfaces or the conditions: - as for the role of the clay type, illite showed a strong affinity for cesium 137; manganese 54 had a particular behaviour with montmorillonite that enhanced its precipitation into MnO 2 ; with cobalt, sodium and zinc, the percentages retained were always [fr

  3. On the calibration of radiotherapy dosemeters in Australia

    International Nuclear Information System (INIS)

    Huntley, R.; Kotler, L.; Webb, D.

    2000-01-01

    Full text: Dosemeters for external beam radiotherapy are calibrated in Australia by ARPANSA, against the national primary standards of exposure and absorbed dose. The primary standards are free air chambers for exposure at low and medium energy X-rays, a graphite cavity chamber for exposure at 60 Co, and a graphite calorimeter for absorbed dose at 60 Co and high energy (MV) X -rays. Radiotherapy dosemeters are calibrated against these standards using a well documented formalism to provide calibration factors suitable for use with dosimetry protocols. A dosemeter usually comprises an ionization chamber connected to an independent electrometer. These are calibrated separately if possible. A combined calibration factor is reported together with the electrometer calibration factor (sensitivity). The dosimetry protocol used in radiotherapy centres in Australia and New Zealand is currently the simplified version of the IAEA TRS277 protocol, published by the New Zealand NRL and recommended by the ACPSEM. This protocol requires the use of an exposure or air kerma calibration factor at 60 Co (Nx or Nk) to evaluate the absorbed dose to air calibration factor N D . The chamber is then placed in a water phantom with its centre displaced from the reference point by p eff . ARPANSA can also supply calibration factors in absorbed dose to water (N D,w ), as required as input to the new IAEA CoP. If an absorbed dose to water calibration factor is used by the radiotherapy centre, the chamber should be placed with its centre at the reference point in the water phantom. ARPANSA has for some years coordinated the participation of Australian radiotherapy centres in the IAEA TLD Quality Audit service. Note that this service does not represent a calibration and should not be referred to as such. The only calibration is that provided by ARPANSA for a reference dosemeter at each radiotherapy centre. As soon as the ANSTO SSDL is operational, calibrations of reference dosemeters will also be

  4. Standard operating procedures for quality audits of 60Co external beam radiotherapy facilities

    International Nuclear Information System (INIS)

    Larrinaga Cortina, E.F.; Dominguez Hung, L.; Campa Menendez, R.

    2001-01-01

    The use of radiotherapy implies the necessity of rigorous quality standards in its different components, aimed to provide the best possible treatment and avoid potential patients' risks, that could even cause him death. Projects of technical cooperation developed in Cuba and supported by the International Atomic Energy Agency address the implementation of Programs of Quality Assurance (PGC) in radiotherapy services. The establishment of the National Quality Audit Program (PNAC) is a superior stage. The National Control Center for Medical Devices, as the national regulator entity for the control and supervision of medical devices in the National Health System, is responsible for the making and execution of the PNAC. The audit modality selected was the inspection visit in situ due to its intrinsic advantages, our geographical extension and the number of radiotherapy services. This paper presents the methodology for the execution of the PNAC, in form of a Normalized Procedure of Operation (PNO) that defines the objectives, scope, terms and definitions, responsibilities, composition and selection of the auditor team, security's conditions, materials and equipment, steps of the audit execution, results calculation and interpretation, records, etc. (author)

  5. PET/CT for atherosclerotic plaque imaging

    International Nuclear Information System (INIS)

    Ben-Haim, S.; Technion Institute of Technology, Haifa; Israel, O.; Rambam Medical Center, Haifa

    2006-01-01

    Atherosclerosis is one of the leading causes of morbidity and mortality in the world. Rupture of atherosclerotic plaques and thrombi formation are the primary mechanisms of myocardial infarction or cerebrovascular accident. Angiography is considered to represent the gold standard technique for imaging of the arterial lumen. However, in recent years it has been realized that the primary determinant of the atherosclerotic plaque stability is the composition of the plaque and other imaging modalities have been suggested. The purpose of this review is to briefly summarize the knowledge accumulated to present date regarding the potential role of fluo deoxyglucose imaging in the assessment of atherosclerosis and to compare this modality to additional available imaging approaches for the detection of vulnerable plaques

  6. Assessment of the Effect of Fruit (Apple and Plain Yoghurt Consumption on Plaque pH

    Directory of Open Access Journals (Sweden)

    Peyvand Moeiny

    2017-09-01

    Full Text Available Introduction: Nowadays, thanks to improvements in fruit yoghurt tastes, more tendencies are seen in their consumption especially among children. Therefore, their cariogenicity evaluation as healthy snacks is important. The goal of this study was the assessment of the consumption effect of two kinds of Iranian fruit (apple and plain yoghurts on dental plaque PH. Methods: In this experimental study, 10 healthy dentistry students were selected upon inclusion criteria. Plaque pH in the certain areas of the mouth was measured by microelectrode and digital pH meter. PH was measured at the baseline and intervals of 2, 5, 7, 10, 15, 20, 30, 40, 50 and 60 minutes after eating test products: fruit yoghurt (apple and plain Yoghurt. For positive control group, just the baseline PH and at intervals of 2 and 5 min after swishing with 10% sucrose solutions were recorded. The results were analyzed using repeated measures ANOVA. Results: Lowest pH was obtained after fruit yoghurt consumption followed by plain yoghurt and %10 sucrose solution and the plaque PH difference was significant (P=0.05. Furthermore, time duration which remained below the critical pH was longer after consuming fruit yoghurt. Conclusion: Both kinds of yoghurts were considered cariogenic since plaque pH drop below critical points. Average of plaque pH after consuming fruit yoghurt was significantly lower in almost all the time intervals

  7. Spots before the eyes: A prevalence and clinicoradiological study of senile scleral plaques

    International Nuclear Information System (INIS)

    Moseley, I.

    2000-01-01

    AIMS: To investigate the prevalence and clinical associations of senile scleral plaques. METHODS: Unselected, consecutive computed tomographic (CT) images of elderly people were reviewed for the presence of calcification indicating senile scleral plaques. RESULTS: No definite calcification was seen in 100 men or 100 women aged 60-69 years; equivocal changes were seen in one woman. There were three definite examples and one equivocal case of calcification in 100 women and four definite cases in 100 men aged 70-79 years. However, in a group of 71 men and women patients aged 80 years or more, 16 definite cases were seen, indicating a prevalence of 22%. CONCLUSIONS: Apart from advanced age, and a mild association with the extent of calcification of the carotid siphon, no clinical or radiological features were identified which consistently characterized a total of 28 patients with this form of ocular calcification; an association with cataract probably reflected simply the recruitment base. Scleral plaques would appear to be a degenerative phenomenon without clinical significance, most likely to be detected in patients presenting with unrelated ophthalmological complaints. Moseley, I. (2000)

  8. Dose enhancement in a room cobalt-60 source

    International Nuclear Information System (INIS)

    Simons, M.; Pease, R.L.; Fleetwood, D.M.; Schwank, J.R.; Krzesniak, M.

    1997-01-01

    A room Co-60 source was characterized using TLDs and pMOS RADFETs. Dose enhancement was measured using RADFETs with and without gold- flashed kovar lids. A methodology was developed to predict dose enhancement vs position and test configuration

  9. Set of devices for producing radioactive 60Co-sources

    International Nuclear Information System (INIS)

    Eichhorn, P.; Tobisch, F.

    1982-01-01

    A set of devices for producing radioactive 60 Co-sources was developed. A single source has a radioactivity of 445x10 10 GBq. It consists of a double envelope of stainless steel filled with a mixture of small pieces of cobalt and stainless steel wire. The diameter of a source is 11 mm; the length 80 mm. Cobalt wires of different radioactivity with a length of about 110 mm and 0,8 mm diameter are the raw material. The set is located in a hot cell. Construction, functions and operation of the set are described in detail. (author)

  10. The effect of pH, temperature and plaque thickness on the hydrolysis of monofluorophosphate in experimental dental plaque.

    Science.gov (United States)

    Pearce, E I F; Dibdin, G H

    2003-01-01

    Monofluorophosphate (MFP), an anti-caries agent commonly used in toothpaste, is known to be degraded to fluoride and orthophosphate by bacterial phosphatases in dental plaque. We have examined the effect of pH, temperature, plaque thickness and some ions on this process. Both natural plaque and artificial microcosm plaque incubated with purified MFP at pH 4-10 showed an optimum pH of approximately 8 for hydrolysis. Diffusion and concomitant hydrolysis were examined in an apparatus in which artificial plaque was held between rigid membranes separating two chambers. When MFP diffused through a plaque of 0.51-mm thickness over 4 h it was almost completely hydrolysed at pH 8, but hydrolysis on diffusion decreased as the pH deviated from 8. MFP in toothpaste extract showed a similar pH susceptibility to hydrolysis, according to the inherent pH of the toothpaste. Hydrolysis of MFP in the toothpaste was reduced by no more than 10% when compared with a matched-pH control, suggesting that other toothpaste ingredients had no major influence on hydrolysis. Transport was slower and hydrolysis at pH 6 more complete the thicker the plaque, but hydrolysis was not significantly slower at 23 degrees C than at 37 degrees C. The addition of various potential activating or inhibiting ions at 0.1 and 1.0 mmol/l had small and non-significant effects on hydrolysis. The results suggest that MFP toothpaste should be formulated and used to maximise enzymic hydrolysis of this complex anion, and that plaque pH control is probably the most important factor. Copyright 2003 S. Karger AG, Basel

  11. Risk appraisal in the radiotherapy patient: “V. I. Lenin” Hospital in Holguin province

    International Nuclear Information System (INIS)

    González López, Dagoberto Eloy; Borjas Hernández, Pedro

    2015-01-01

    An accident is usually caused by the simultaneous occurrence of human errors and equipment failure. In medical applications, the radiation therapy is the increased risk of complexity presented by treatments in patients. The different accidents that have occurred in the world in this practice show the need for safety analysis in order to identify and prevent accidental exposures. In this regard, the effectiveness of the semiquantitative method of “risk matrices”, which consists of a combined analysis of the frequency of occurrence of the event causing the accident, the chance of human errors or failure of the safety barriers, in addition to recognizing the seriousness of the consequences resulting from such events; which define the acceptability criteria based on risk. In this research, this method was applied for safety evaluation analysis of the radiotherapy service at Holguin hospital, which uses a cobalt 60 Theratron Phoenix equipment. The study allowed to quantify the radiotherapy service strengths, to identify the most significant contributors to risk events from the viewpoint of safety, as well as to adopt the most appropriate mitigation measures in order to decrease the occurrence of such accidents. The risk of a large number of accident sequences caused by all possible human errors and equipment failures in the service was estimated, and it was also observed and consequently concluded that none of the accident sequences was considered as very high risk thus confirming that there is no imminent risk which could result in an accident at this facility. (author)

  12. Chemotherapy as an adjuvant to Radiotherapy in treatment of Retinoblastoma

    International Nuclear Information System (INIS)

    Ahmed, A.H.M.

    2015-01-01

    Retinoblastoma is the most common primary intraocular malignancy of childhood. A potentially curable cancer, its treatment has improved significantly over the last few decades. Various studies show that while enucleation remains the standard of care for advanced intraocular tumours, conservative modalities that can result in globe salvage and preservation of useful vision are being increasingly employed. Such modalities include systemic chemotherapy, focal consolidation with transpupillary thermo therapy, laser photocoagulation and cryotherapy, plaque brachytherapy, and delivery of local chemotherapy using subconjunctival, sub-tenon, or intra-arterial routes. When used alone or in combination, these treatment modalities can help in avoidance of external beam radiotherapy or enucleation, thus reducing the potential for long-term side effects, while salvaging useful vision. Radioactive plaque brachytherapy has an established role in selected patients with intraocular retinoblastoma. Local injections of chemotherapeutic agents via the sub-tenon or sub-conjunctival route have been used with varying degrees of success, usually as an adjunct to systemic chemotherapy. Intra-arterial ophthalmic artery delivery of melphalan has shown promising results.

  13. Altered carotid plaque signal among different repetition times on T1-weighted magnetic resonance plaque imaging with self-navigated radial-scan technique

    Energy Technology Data Exchange (ETDEWEB)

    Narumi, Shinsuke; Ohba, Hideki; Mori, Kiyofumi; Ohura, Kazumasa; Ono, Ayumi; Terayama, Yasuo [Iwate Medical University, Department of Neurology and Gerontology, Morioka (Japan); Sasaki, Makoto [Iwate Medical University, Advanced Medical Research Center, Morioka (Japan); Ogasawara, Kuniaki [Iwate Medical University, Department of Neurosurgery, Morioka (Japan); Hitomi, Jiro [Iwate Medical University, Department of Anatomy, Morioka (Japan)

    2010-04-15

    Magnetic resonance (MR) plaque imaging for carotid arteries is usually performed by using an electrocardiograph (ECG)-gating technique to eliminate pulsation-related artifacts, which can affect the plaque signals because of varied repetition time (TR) among patients. Hence, we investigated whether differences in TR causes signal alterations of the carotid plaque by using a non-gated plaque imaging technique. We prospectively examined 19 patients with carotid stenosis by using a T1-weighted self-navigated radial-scan technique with TRs of 500, 700, and 900 ms. The signal intensity of the carotid plaque was measured, and the contrast ratio (CR) relative to the adjacent muscle was calculated. CRs of the carotid plaques were 1.39 {+-} 0.39, 1.29 {+-} 0.29, and 1.23 {+-} 0.24 with TRs of 500, 700, and 900 ms, respectively, and were significantly different. Among the plaques, those with a hyperintensity signal (CR > 1.5) and moderate-intensity signal (CR 1.2-1.5) at 500 ms showed a TR-dependent signal decrease (hyperintensity plaques, 1.82 {+-} 0.26; 1.61 {+-} 0.19; and 1.48 {+-} 0.17; moderate-intensity plaques, 1.33 {+-} 0.08; 1.26 {+-} 0.08; and 1.19 {+-} 0.07), while those with an isointensity signal (CR < 1.2) remained unchanged regardless of TR (0.96 {+-} 0.12, 0.96 {+-} 0.11, and 0.97 {+-} 0.13). The signal intensity of the carotid plaque on T1-weighted imaging significantly varies among different TRs and tends to decrease with longer TR. MR plaque imaging with short and constant TR settings that the ECG-gating method cannot realize would be preferable for evaluating plaque characteristics. (orig.)

  14. Chemo-radiotherapy for malignant brain tumors

    Energy Technology Data Exchange (ETDEWEB)

    Kochi, Masato; Ushio, Yukitaka [Kumamoto Univ. (Japan). School of Medicine

    2002-05-01

    Malignant gliomas: Randomized clinical trials conducted in the USA showed that radiotherapy plus chemotherapy with nitrosoureas offered a long-term survival advantage to patients younger than 60 years old with malignant gliomas. Combination chemotherapy, such as procarbazine/CCNU/vincristine (PCV) must be tested further, and intra-arterial chemotherapy with nitrosoureas offered no survival advantage. Combination chemotherapy with PCV showed efficacy for patients with anaplastic oligodendroglioma and anaplastic oligoastrocytoma. Medulloblastoma: The addition of chemotherapy to radiotherapy improved the survival of patients with poor risk medulloblastoma, and may reduce the required craniospinal radiation dose in patients with good risk medulloblastoma. Primary CNS lymphoma (PCNSL): Combination of chemotherapy with high-dose MTX and radiotherapy improved survival of patients with PCNSL; however, the neurotoxicity produced by this treatment modality is a serious problem in older patients. Intracranial germ cell tumors: The addition of chemotherapy to radiotherapy may produce long term survival with good quality of life in patients with germinoma. Neoadjuvant therapy consisting of chemotherapy and radiotherapy followed by complete surgical excision improved survival of patients with intracranial nongerminomatous germ cell tumors. (author)

  15. Chemo-radiotherapy for malignant brain tumors

    International Nuclear Information System (INIS)

    Kochi, Masato; Ushio, Yukitaka

    2002-01-01

    Malignant gliomas: Randomized clinical trials conducted in the USA showed that radiotherapy plus chemotherapy with nitrosoureas offered a long-term survival advantage to patients younger than 60 years old with malignant gliomas. Combination chemotherapy, such as procarbazine/CCNU/vincristine (PCV) must be tested further, and intra-arterial chemotherapy with nitrosoureas offered no survival advantage. Combination chemotherapy with PCV showed efficacy for patients with anaplastic oligodendroglioma and anaplastic oligoastrocytoma. Medulloblastoma: The addition of chemotherapy to radiotherapy improved the survival of patients with poor risk medulloblastoma, and may reduce the required craniospinal radiation dose in patients with good risk medulloblastoma. Primary CNS lymphoma (PCNSL): Combination of chemotherapy with high-dose MTX and radiotherapy improved survival of patients with PCNSL; however, the neurotoxicity produced by this treatment modality is a serious problem in older patients. Intracranial germ cell tumors: The addition of chemotherapy to radiotherapy may produce long term survival with good quality of life in patients with germinoma. Neoadjuvant therapy consisting of chemotherapy and radiotherapy followed by complete surgical excision improved survival of patients with intracranial nongerminomatous germ cell tumors. (author)

  16. TH-AB-BRA-02: Automated Triplet Beam Orientation Optimization for MRI-Guided Co-60 Radiotherapy

    International Nuclear Information System (INIS)

    Nguyen, D; Thomas, D; Cao, M; O’Connor, D; Lamb, J; Sheng, K

    2016-01-01

    Purpose: MRI guided Co-60 provides daily and intrafractional MRI soft tissue imaging for improved target tracking and adaptive radiotherapy. To remedy the low output limitation, the system uses three Co-60 sources at 120° apart, but using all three sources in planning is considerably unintuitive. We automate the beam orientation optimization using column generation, and then solve a novel fluence map optimization (FMO) problem while regularizing the number of MLC segments. Methods: Three patients—1 prostate (PRT), 1 lung (LNG), and 1 head-and-neck boost plan (H&NBoost)—were evaluated. The beamlet dose for 180 equally spaced coplanar beams under 0.35 T magnetic field was calculated using Monte Carlo. The 60 triplets were selected utilizing the column generation algorithm. The FMO problem was formulated using an L2-norm minimization with anisotropic total variation (TV) regularization term, which allows for control over the number of MLC segments. Our Fluence Regularized and Optimized Selection of Triplets (FROST) plans were compared against the clinical treatment plans (CLN) produced by an experienced dosimetrist. Results: The mean PTV D95, D98, and D99 differ by −0.02%, +0.12%, and +0.44% of the prescription dose between planning methods, showing same PTV dose coverage. The mean PTV homogeneity (D95/D5) was at 0.9360 (FROST) and 0.9356 (CLN). R50 decreased by 0.07 with FROST. On average, FROST reduced Dmax and Dmean of OARs by 6.56% and 5.86% of the prescription dose. The manual CLN planning required iterative trial and error runs which is very time consuming, while FROST required minimal human intervention. Conclusions: MRI guided Co-60 therapy needs the output of all sources yet suffers from unintuitive and laborious manual beam selection processes. Automated triplet orientation optimization is shown essential to overcome the difficulty and improves the dosimetry. A novel FMO with regularization provides additional controls over the number of MLC segments

  17. TH-AB-BRA-02: Automated Triplet Beam Orientation Optimization for MRI-Guided Co-60 Radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Nguyen, D; Thomas, D; Cao, M; O’Connor, D; Lamb, J; Sheng, K [Department of Radiation Oncology, University of California Los Angeles, Los Angeles, CA (United States)

    2016-06-15

    Purpose: MRI guided Co-60 provides daily and intrafractional MRI soft tissue imaging for improved target tracking and adaptive radiotherapy. To remedy the low output limitation, the system uses three Co-60 sources at 120° apart, but using all three sources in planning is considerably unintuitive. We automate the beam orientation optimization using column generation, and then solve a novel fluence map optimization (FMO) problem while regularizing the number of MLC segments. Methods: Three patients—1 prostate (PRT), 1 lung (LNG), and 1 head-and-neck boost plan (H&NBoost)—were evaluated. The beamlet dose for 180 equally spaced coplanar beams under 0.35 T magnetic field was calculated using Monte Carlo. The 60 triplets were selected utilizing the column generation algorithm. The FMO problem was formulated using an L2-norm minimization with anisotropic total variation (TV) regularization term, which allows for control over the number of MLC segments. Our Fluence Regularized and Optimized Selection of Triplets (FROST) plans were compared against the clinical treatment plans (CLN) produced by an experienced dosimetrist. Results: The mean PTV D95, D98, and D99 differ by −0.02%, +0.12%, and +0.44% of the prescription dose between planning methods, showing same PTV dose coverage. The mean PTV homogeneity (D95/D5) was at 0.9360 (FROST) and 0.9356 (CLN). R50 decreased by 0.07 with FROST. On average, FROST reduced Dmax and Dmean of OARs by 6.56% and 5.86% of the prescription dose. The manual CLN planning required iterative trial and error runs which is very time consuming, while FROST required minimal human intervention. Conclusions: MRI guided Co-60 therapy needs the output of all sources yet suffers from unintuitive and laborious manual beam selection processes. Automated triplet orientation optimization is shown essential to overcome the difficulty and improves the dosimetry. A novel FMO with regularization provides additional controls over the number of MLC segments

  18. Long-term alterations of oral mucosa in radiotherapy patients

    International Nuclear Information System (INIS)

    Prott, Franz-Josef; Handschel, Joerg; Micke, Oliver; Sunderkoetter, Cord; Meyer, Ulrich; Piffko, Josef

    2002-01-01

    Purpose: The aim of this investigation was to describe the alterations in oral mucosa after radiotherapy. Methods and Materials: Biopsies were taken from patients before irradiation, at 60 Gy, and 6-12 months after radiotherapy. Histomorphological evaluation of the vessels was performed, and endothelial expression of ICAM-1, VCAM-1, and E-selectin was also evaluated, as well as distribution of LFA-1-, Mac-1-, VLA-4-, RM3/1-, 27E10-, and 25F9-bearing cells in the subepithelial tissue. Results: The expression of ICAM-1 was downregulated after radiotherapy, whereas the percentage of LFA-1- and VLA-4-bearing cells increased. VCAM-1 remained at low levels. The subepithelial infiltration was still dominated by RM3/1-positive macrophages. The number of vessels decreased, while the lumina of the remaining vessels in the deeper connective layer increased. Conclusions: The late effects of radiotherapy are characterized by a decreased number of blood vessels and by significantly different expression patterns of the adhesion molecules studied, and of integrins and macrophage subpopulations compared to the conditions before irradiation and at 60 Gy

  19. Effects of continuous hyperfractionated accelerated and conventionally fractionated radiotherapy on the parotid and submandibular salivary glands of rhesus monkeys

    International Nuclear Information System (INIS)

    Price, R.E.; Ang, K.K.; Stephens, L.C.; Peters, L.J.

    1995-01-01

    Radiotherapy is a major treatment modality for head and neck cancer. It is often not possible to exclude the salivary glands from the treatment fields. The unique susceptibility of the serous cells of the salivary glands to irradiation often results in xerostomia with ensuing secondary complications and discomfort to the patients. Recent reports have suggested that continuous hyperfractionated accelerated radiotherapy (CHART) can lead to considerably less reduction in salivary flow of the parotid salivary gland than conventional radiotherapy. This study was undertaken to assess histologic changes of salivary glands induced by CHART and conventional radiation fractionation schedules. The parotid and submandibular salivary glands of adult rhesus monkeys were irradiated with cobalt-60 γ radiation at 50 Gy/20 fractions/4 weeks, 55 Gy/25 fractions/5 weeks, or 54 Gy/36 fractions/12 days (CHART). Salivary tissues were harvested at 16 weeks following irradiation and evaluated histopathologically. Microscopically, the glands receiving 50 Gy, 55 Gy, or CHART were virtually indistinguishable. There was severe atrophy and fibrosis of all glands. Quantitative analysis revealed that 50 Gy, 55 Gy, and CHART induced a reduction of serous acini in parotid glands by 86.4%, 84.8%, and 88.8%, respectively. In submandibular glands, serous acini were reduced by 99.4%, 99.0%, and 100%, respectively. The corresponding reduction in mucous acini were 98.4%, 98.4%, and 99.2%, respectively. These histopathologic and quantitative morphologic studies show that the magnitude of serous gland atrophy in the parotid and submandibular salivary glands of rhesus monkeys was similar at 16 weeks after receiving 50 Gy in 20 fractions, 55 Gy in 25 fractions, or CHART

  20. Radical radiotherapy for T3 laryngeal cancers

    International Nuclear Information System (INIS)

    Uno, T.; Itami, J.; Kotaka, K.; Toriyama, M.

    1996-01-01

    From 1974 through 1992, 37 previously untreated patients with T3 laryngeal cancer (supraglottic 15, glottic 22) were treated with initial radical radiotherapy and surgery for salvage. Two-year local control rate with radiotherapy alone, ultimate voice preservation rate, and ultimate local control rate for T3 supraglottic cancer were 33%, 33%, and 60%, respectively. Corresponding figures for T3 glottic cancer were 32%, 23%, and 77%, respecitvely. Five-year cause-specific survival rate for T3 supraglottic cancer and glottic cancer were 47% and 77%, respectively. In T3 supraglottic cancer, none of the 4 patients with subglottic tumor extension attained local control by radiotherapy alone, and local-regional recurrence-free time were significantly shorter in patients with subglottic tumor extension or tracheostomy before radiotherapy. There were no serious late complications such as chondronecrosis, rupture of carotid artery attributed to radical radiotherapy, while 3 patients had severe laryngeal edema requiring total laryngectomy. (orig.) [de

  1. Radiotherapy for solitary plasmacytoma and multiple myeloma

    International Nuclear Information System (INIS)

    Schmaus, M.C.; Neuhof, D.

    2014-01-01

    Solitary plasmacytoma and multiple myeloma require a differentiated radiotherapy. The irradiation for plasmacytoma with an adequate total dose (medullary 40-50 Gy or extramedullary 50-60 Gy) leads to a high degree of local control with a low rate of side effects. In cases of multiple myeloma radiotherapy will achieve effective palliation, both in terms of recalcification as well as reduction of neurological symptoms and analgesia. In terms of analgesia the rule is the higher the single dose fraction the faster the reduction of pain. As part of a conditioning treatment prior to stem cell transplantation radiotherapy contributes to the establishment of a graft versus myeloma effect (GVM). (orig.) [de

  2. Determination of dosimetric parameters of Asymmetric fields from those of Symmetric fields for equinox 100 Cobalt-60 teletherapy machine

    International Nuclear Information System (INIS)

    Mensah, K.

    2014-07-01

    The Theratron Equinox 100 Cobalt-60 therapy unit is equipped wtih x-ray collimators or jaws that can be moved independently or allow asymmetric fields with field centres positioned away from the true central axis of the beam. Although asymmetric collimation can be performed by beam splitters or secondary blocking on a shadow tray; an independent jaw feature reduces the set-up time and spares the therapist from handling heavy blocks. Clinical sites where asymmetric jaws are typically used include breast, head and neck, craniospinal and prostate. Knowledge of the dose distribution of asymmetric fields is required to help evaluate the dosimetry of this non-standard treatment delivery technique prior to clinical implementation. IBA StarTrack 2-D array was used to acquire beam profiles of symmetric and asymmetric beams of different field sizes and varying depth using the Theratron Equinox 100 Cobalt-60 teletherapy unit. The 2-D water phantom was then used to measure PDDs and output factors of both the symmetric and asymmetric beams at varying depths and field sizes. The off-axis ratio was also determined from the half beam profile of the largest field size of the treatment machine and then the output factor ratios were used to validate it. The treatment planning system was then used to model both the symmetric and asymmetic beams and the PDDs and output factors were also calculated. Beam profiles for asymmetry beams showed good agreement with symmetry beam profiles for smaller field sizes and the deviations among them steadily became more evident with increasing field sizes. This difference in the dose distribution for asymmetric fields compared to the dose distribution for symmetric fields was due to the tilt of the dose profiles towards the beam axis. This tilt in the dose profiles of the asymmetic beams was caused by the oblique incidence of the asymmetric beam at off-axis locations, causing less beam hardening compared to that along the central axis. In treatment

  3. Activation measurements for thermal neutrons. Part A. Cobalt (60Co) activation

    International Nuclear Information System (INIS)

    Kerr, George D.; Shizuma, Kiyoshi; Endo, Satoru; Maruyama, Takashi; Cullings, Harry M.; Komura, Kazuhisa; Okumura, Yutaka; Egbert, Stephen D.

    2005-01-01

    The 60 Co measurements at Hiroshima and Nagasaki were reviewed and compared with the results of the new DS02 calculations for the two cities. Some corrections were made to previously published data from the 1965 measurements of JNIRS, ground ranges of all of the 60 Co measurements were reviewed and new ground ranges were determined when possible by transforming sample coordinates to the new city maps for Hiroshima and Nagasaki, and transmission factors were investigated for a number of samples used in the 60 Co measurements. Transmission factors were not calculated for all samples used in the 60 Co measurements but some general rules were given for estimating transmission factors for these samples. Experimental measurements of the background 60 Co activity from environmental neutrons were also reviewed, and it was found that the 60 Co background from environmental neutrons was not an important factor in the 60 Co measurements of bomb-induced activity at either city. (J.P.N.)

  4. Radiotherapy-induced emesis. An overview

    International Nuclear Information System (INIS)

    Feyer, P.; Buchali, A.; Hinkelbein, M.; Budach, V.; Zimmermann, J.S.; Titlbach, O.J.

    1998-01-01

    Background: A significant number of patients receiving radiotherapy experience the distressing side effects of emesis and nausea. These symptoms are some of the most distressing problems for the patients influencing their quality of life. Methods: International study results concerning radiotherapy-induced emesis are demonstrated. A German multicenter questionnaire examining the strategies to prevent or to treat radiotherapy-induced nausea and emesis is presented. An international analysis concerning incidence of emesis and nausea in fractionated radiotherapy patients is discussed. Finally the consensus of the consensus conference on antiemetic therapy from the Perugia International Cancer Conference V is introduced. Results: Untreated emesis can lead to complications like electrolyte disorders, dehydration, metabolic disturbances and nutrition problems with weight loss. Prophylactic antiemetics are often given to patients receiving single high-dose radiotherapy to the abdomen. A survey has revealed that antiemetic prophylaxis is not routinely offered to the patients receiving fractionated radiotherapy. However, there is a need for an effective treatment of emesis for use in this group of patients, too. In 20% of patients nausea and emesis can cause a treatment interruption because of an inadequate control of symptoms. Like in chemotherapy strategies there exist high, moderate, and low emetogenic treatment regimens in radiotherapy as well. The most emetogenic potential has the total body irradiation followed by radiotherapy to the abdomen. Radiotherapy induced emesis can be treated effectively with conventional antiemetics up to 50%. Conclusions: Studies with total body irradiation, fractionated treatment and high-dose single exposures have cleary demonstrated the value of 5-HT3-receptor antagonist antiemetics. There is a response between 60 and 97%. There is no difference in the efficacy of the different 5-HT3-antagonists. High-risk patients should be prophylactic

  5. Association of Streptococcus with Plaque Type of Psoriasis

    Directory of Open Access Journals (Sweden)

    Mohammad Akram Hossain

    2015-05-01

    Full Text Available Background: Guttate psoriasis has a well-known association with streptococcal throat infections, but the effects of these infections in patients with chronic plaque type of psoriasis remains to be evaluated. In Bangladesh several studies were done on psoriasis but no data about association between streptococcal throat infection and plaque type psoriasis are available so far. Considering the co-morbidities of psoriasis patients, it might be justifiable to find out the events that provoke the initiation or exacerbation of psoriatic disease process. Objective: To observe the association of streptococcus with plaque type of psoriasis. Materials and Methods: This observational study was conducted in the department of Dermatology and Venereology, Bangabandhu Sheikh Mujib Medical University, Dhaka. Forty seven patients clinically and histopathologically diagnosed as having plaque psoriasis were selected as cases and patients with skin diseases other than psoriasis were selected as controls. Results: In this study majority of subjects (55% were diagnosed as chronic plaque psoriasis. Among the subjects with guttate flare of chronic plaque psoriasis 64.2% gave a positive history of sore throat. ASO titer was raised (>200 IU/mL in 28 (59.5% patients of chronic plaque psoriasis and 7 (17.9% patients of non-psoriatic respondents. The difference between two groups was significant (p0.05. Conclusion: This study shows that streptococcal throat infections are associated with plaque psoriasis and early treatment of throat infections may be beneficial for plaque type of psoriasis patients.

  6. Impurity diffusion of cobalt in plutonium

    International Nuclear Information System (INIS)

    Charissoux, Christian; Calais, Daniel.

    1975-01-01

    The sectioning method for investigation of the impurity diffusion of 60 Co in the fcc and bcc phases of plutonium gives the following results: 344-426 deg C: D=1.2x10 -2 exp(-12700/RT)cm 2 /s in delta Pu(fcc); 484-621 deg C: D=1.4x10 -3 exp(-9900/RT)cm 2 /s in epsilon Pu(bcc). Cobalt is a fast diffuser in plutonium; the diffusion coefficient being unaffected by phase changes delta'→delta; delta'→epsilon, the diffusion mechanism is probably dissociative in both phases, the solute becoming interstitial by: solute (substitution) reversible solute (interstitial) + vacancy [fr

  7. Nitrogen-doped carbon-supported cobalt-iron oxygen reduction catalyst

    Science.gov (United States)

    Zelenay, Piotr; Wu, Gang

    2014-04-29

    A Fe--Co hybrid catalyst for oxygen reaction reduction was prepared by a two part process. The first part involves reacting an ethyleneamine with a cobalt-containing precursor to form a cobalt-containing complex, combining the cobalt-containing complex with an electroconductive carbon supporting material, heating the cobalt-containing complex and carbon supporting material under conditions suitable to convert the cobalt-containing complex and carbon supporting material into a cobalt-containing catalyst support. The second part of the process involves polymerizing an aniline in the presence of said cobalt-containing catalyst support and an iron-containing compound under conditions suitable to form a supported, cobalt-containing, iron-bound polyaniline species, and subjecting said supported, cobalt-containing, iron bound polyaniline species to conditions suitable for producing a Fe--Co hybrid catalyst.

  8. Atherosclerotic Plaque Destabilization in Mice: A Comparative Study.

    Directory of Open Access Journals (Sweden)

    Helene Hartwig

    Full Text Available Atherosclerosis-associated diseases are the main cause of mortality and morbidity in western societies. The progression of atherosclerosis is a dynamic process evolving from early to advanced lesions that may become rupture-prone vulnerable plaques. Acute coronary syndromes are the clinical manifestation of life-threatening thrombotic events associated with high-risk vulnerable plaques. Hyperlipidemic mouse models have been extensively used in studying the mechanisms controlling initiation and progression of atherosclerosis. However, the understanding of mechanisms leading to atherosclerotic plaque destabilization has been hampered by the lack of proper animal models mimicking this process. Although various mouse models generate atherosclerotic plaques with histological features of human advanced lesions, a consensus model to study atherosclerotic plaque destabilization is still lacking. Hence, we studied the degree and features of plaque vulnerability in different mouse models of atherosclerotic plaque destabilization and find that the model based on the placement of a shear stress modifier in combination with hypercholesterolemia represent with high incidence the most human like lesions compared to the other models.

  9. Bone marrow endothelial progenitors in atherosclerotic plaque resolution

    Science.gov (United States)

    Yao, Longbiao; Heuser-Baker, Janet; Herlea-Pana, Oana; Barlic-Dicen, Jana

    2013-01-01

    Atherosclerosis is a major cause of morbidity and mortality in the United States. Persistently elevated circulating low-density lipoprotein, or hypercholesterolemia, and deposition of low-density lipoprotein in the vascular wall are the main inducers of atherosclerosis, which manifests itself as arterial lesions or plaques. Some plaques become thrombosis-prone and rupture, causing acute myocardial infarction or stroke. Lowering plasma cholesterol through the use of statins is the primary intervention against atherosclerosis. Treatment with statins slows progression of atherosclerosis but can only support limited plaque regression. Partially regressed plaques continue to pose a serious threat due to their remaining potential to rupture. Thus, new interventions inducing complete reversal of atherosclerosis are being sought. Implementation of new therapies will require clear understanding of the mechanisms driving plaque resolution. In this Commentary, we highlight the role of bone marrow endothelial progenitors in atherosclerotic plaque regression and discuss how regenerative cell-based interventions could be used in combination with plasma lipid-lowering to induce plaque reversal in order to prevent and/or reduce adverse cardiovascular events. PMID:23538778

  10. Treatment of radioactive liquid waste (Co-60) by sorption on Zeolite Na-A prepared from Iraqi kaolin

    International Nuclear Information System (INIS)

    Mustafa, Yasmen A.; Zaiter, Maysoon J.

    2011-01-01

    Highlights: ► Iraqi synthetic zeolite type Na-A has been suggested as ion exchange material to treat cobalt-60 in radioactive liquid waste which came from neutron activation for corrosion products. ► The ability of Na-A zeolite to remove cobalt from wastewater was checked for high cobalt concentration (822 mg/L) in addition to low cobalt concentration in the source sample (0.093 mg/L). ► The effects of important design variables on the zeolite column performance were studied these include initial concentration, flow rate, and bed depth. ► The experimental results show that high sorption capacity can be obtained at high influent concentration, low flow rate, and high bed depth. ► Higher column performance was obtained at higher bed depth. - Abstract: Iraqi synthetic zeolite type Na-A has been suggested as ion exchange material to treat cobalt-60 in radioactive liquid waste which came from neutron activation for corrosion products. Batch experiments were conducted to find out the equilibrium isotherm for source sample .The equilibrium isotherm for radioactive cobalt in the source sample showed unfavorable type, while the equilibrium isotherm for the total cobalt (the radioactive and nonradioactive cobalt) in the source sample showed a favorable type. The ability of Na-A zeolite to remove cobalt from wastewater was checked for high cobalt concentration (822 mg/L) in addition to low cobalt concentration in the source sample (0.093 mg/L). A good fitting for the experimental data with Langmuir equilibrium model was observed. Langmuir constant qm which is related to monolayer adsorption capacity for low and high cobalt concentration was determined to be 0.021 and 140 mg/g zeolite . The effects of important design variables on the zeolite column performance were studied these include initial concentration, flow rate, and bed depth. The experimental results have shown that high sorption capacity can be obtained at high influent concentration, low flow rate, and

  11. Synthesis of new cobalt aluminophosphate framework by opening a cobalt methylphosphonate layered material

    Czech Academy of Sciences Publication Activity Database

    Zaarour, M.; Pérez, O.; Boullay, P.; Martens, J.; Mihailova, B.; Karaghiosoff, K.; Palatinus, Lukáš; Mintova, S.

    2017-01-01

    Roč. 19, č. 34 (2017), s. 5100-5105 ISSN 1466-8033 Institutional support: RVO:68378271 Keywords : cobalt aluminophosphate * cobalt methylphosphonate * layered materials * crystallic structure * X-ray diffraction Subject RIV: BM - Solid Matter Physics ; Magnetism OBOR OECD: Condensed matter physics (including formerly solid state physics, supercond.) Impact factor: 3.474, year: 2016

  12. Sorption behaviour of cobalt-60 on Suez Canal bottom sediments

    International Nuclear Information System (INIS)

    Abdel Gawad, S.A.; El-Shinawy, R.M.K.; Abdel Malik, W.E.Y.

    1981-01-01

    Mineralogical, elemental analysis and sorption behaviour of the Suez Canal bottom sediments in the Port Said area were investigated. It was found that the bottom sediment consist mainly of quartz, feldspars and traces of calcite mineral. The cation-exchange capacity was found to increase as the particle size of the sediment decreased. Sorption of 60 Co by the bottom sediment increased with contact time up to 6 h. Variation of the solution pH from 4 to 9 showed limited increase in the sorption of 60 Co. As carrier concentrations increase from 10 -7 N to 10 -3 N, sorption of Co was found to increase linearly following Freundlich isotherm. The presence of Mg 2+ and Fe 3+ in solution depressed the sorption of 60 Co by the sediments. The desorption of 60 Co from bottom sediment with distilled and Suez Canal water was found to increase with contact time. (author)

  13. 3D Fiber Orientation in Atherosclerotic Carotid Plaques

    NARCIS (Netherlands)

    A.C. Akyildiz (Ali); C.-K. Chai (Chen-Ket); C.W.J. Oomens (Cees); A. van der Lugt (Aad); F.P.T. Baaijens (Frank); G.J. Strijkers (Gustav); F.J.H. Gijsen (Frank)

    2017-01-01

    textabstractAtherosclerotic plaque rupture is the primary trigger of fatal cardiovascular events. Fibrillar collagen in atherosclerotic plaques and their directionality are anticipated to play a crucial role in plaque rupture. This study aimed assessing 3D fiber orientations and architecture in

  14. Molecular mechanics calculations on cobalt phthalocyanine dimers

    NARCIS (Netherlands)

    Heuts, J.P.A.; Schipper, E.T.W.M.; Piet, P.; German, A.L.

    1995-01-01

    In order to obtain insight into the structure of cobalt phthalocyanine dimers, molecular mechanics calculations were performed on dimeric cobalt phthalocyanine species. Molecular mechanics calculations are first presented on monomeric cobalt(II) phthalocyanine. Using the Tripos force field for the

  15. [Evaluation of dental plaque by quantitative digital image analysis system].

    Science.gov (United States)

    Huang, Z; Luan, Q X

    2016-04-18

    To analyze the plaque staining image by using image analysis software, to verify the maneuverability, practicability and repeatability of this technique, and to evaluate the influence of different plaque stains. In the study, 30 volunteers were enrolled from the new dental students of Peking University Health Science Center in accordance with the inclusion criteria. The digital images of the anterior teeth were acquired after plaque stained according to filming standardization.The image analysis was performed using Image Pro Plus 7.0, and the Quigley-Hein plaque indexes of the anterior teeth were evaluated. The plaque stain area percentage and the corresponding dental plaque index were highly correlated,and the Spearman correlation coefficient was 0.776 (Pchart showed only a few spots outside the 95% consistency boundaries. The different plaque stains image analysis results showed that the difference of the tooth area measurements was not significant, while the difference of the plaque area measurements significant (P<0.01). This method is easy in operation and control,highly related to the calculated percentage of plaque area and traditional plaque index, and has good reproducibility.The different plaque staining method has little effect on image segmentation results.The sensitive plaque stain for image analysis is suggested.

  16. Changes in pulmonary function after definitive radiotherapy for NSCLC

    DEFF Research Database (Denmark)

    Schytte, Tine; Bentzen, Søren M; Brink, Carsten

    2015-01-01

    a negative impact on FVC. Long-term FEV1 and FVC were analyzed using linear regression. Treatment year and V60 had a significant impact on loss of FEV1. V60 had a significant impact on FVC changes. CONCLUSION: In this study, early PF change reached a plateau at 6months after the start of radiotherapy......INTRODUCTION: The objective of this study was to identify factors associated with early and long-term pulmonary function (PF) changes after definitive radiotherapy for NSCLC patients. PF was measured by spirometry i.e. forced expiratory volume in 1s (FEV1), and forced vital capacity (FVC...

  17. AN ELECTROPLATING METHOD OF FORMING PLATINGS OF NICKEL, COBALT, NICKEL ALLOYS OR COBALT ALLOYS

    DEFF Research Database (Denmark)

    1997-01-01

    An electroplating method of forming platings of nickel, cobalt, nickel alloys or cobalt alloys with reduced stresses in an electrodepositing bath of the type: Watt's bath, chloride bath or a combination thereof, by employing pulse plating with periodic reverse pulse and a sulfonated naphthalene...

  18. Initial stress in biomechanical models of atherosclerotic plaques

    NARCIS (Netherlands)

    Speelman, L.; Akyildiz, A.C.; Adel, den B.; Wentzel, J.J.; Steen, van der A.F.W.; Virmani, R.; Weerd, van der L.; Jukema, J.W.; Poelmann, R.E.; Brummelen, van E.H.; Gijsen, F.J.H.

    2011-01-01

    Rupture of atherosclerotic plaques is the underlying cause for the majority of acute strokes and myocardial infarctions. Rupture of the plaque occurs when the stress in the plaque exceeds the strength of the material locally. Biomechanical stress analyses are commonly based on pressurized

  19. Degradation of the insecticide ethyl parathion in different environmental matrices by gamma radiation from Cobalt-60

    International Nuclear Information System (INIS)

    Luchini, Luiz Carlos

    1995-01-01

    This work studies the use of gamma radiation from cobalt-60 to induce parathion degradation in different matrices, as well as, quantified GC-NPD and identified by GC-MS, the radiolysis resulting products. Results show that the insecticide was completely degraded in aqueous solution after treatment with 1.0 kGy dosis in a dosis rate of 3.12 kGy h -1 . In methanol, parathion was completely degraded only with 30 kGy at 3.12 kGy h -1 . The metabolites detected after radiolysis were the same formed by biological degradation, i.e, p-nitrophenol, p-aminophenol, paraoxon and aminoparathion. The gamma radiation also degraded paraoxon which is the most toxic metabolite of parathion. It was verified that, not only the total radiation, but also the dosis rate supplied to the aqueous solution had a significant effect on the insecticide degradation, and the formation of metabolites occurred in a selective way respecting the dosis and dosis rate. Otherwise, the gamma radiation did almost not degraded the parathion adsorbed in solid matrices as rice, moist and dry soil, even using dosis of 5,30 and 50 kGy, respectively. The parathion yield and the dosis of gamma radiation needed for 50% reduction of the insecticide initial concentration in aqueous solution were also calculated and presented. Thus, it was verified that irradiation of parathion besides to be an important instrument for environmental decontamination of this pesticide in aqueous matrix, it allows the production of parathion metabolites for ecotoxicological studies. (author)

  20. Study of complex formation of cobalt (II) and cobalt (III) in acrylamide aqueous solutions and in the phase of acrylamide hydrogel

    International Nuclear Information System (INIS)

    Ismailova, M.M.; Egorova, L.A.; Khamidov, B.O.

    1993-01-01

    Present article is devoted to study of complex formation of cobalt (II) and cobalt (III) in acrylamide aqueous solutions and in the phase of acrylamide hydrogel. The condition of cobalt in various rate of oxidation in acrylamide aqueous solutions was studied. The concentration conditions of stability of system Co(II)-Co(III) were defined. The composition of coordination compounds of cobalt (II) and cobalt (III) in acrylamide aqueous solutions and in the phase of acrylamide hydrogel was determined.