WorldWideScience

Sample records for cobalt 60

  1. The cobalt-60 container scanner

    International Nuclear Information System (INIS)

    Jigang, A.; Liye, Z.; Yisi, L.; Haifeng, W.; Zhifang, W.; Liqiang, W.; Yuanshi, Z.; Xincheng, X.; Furong, L.; Baozeng, G.; Chunfa, S.

    1997-01-01

    The Institute of Nuclear Energy Technology (INET) has successfully designed and constructed a container (cargo) scanner, which uses cobalt-60 of 100-300 Ci as radiation source. The following performances of the Cobalt-60 container scanner have been achieved at INET: a) IQI (Image Quality Indicator) - 2.5% behind 100 mm of steel; b) CI (Contrast Indicator) - 0.7% behind 100 mm of steel; c) SP (Steel Penetration) - 240 mm of steel; d) Maximum Dose per Scanning - 0.02mGy; e) Throughput - twenty 40-foot containers per hour. These performances are equal or similar to those of the accelerator scanners. Besides these nice enough inspection properties, the Cobalt-60 scanner possesses many other special features which are better than accelerator scanners: a) cheap price - it will be only or two tenths of the accelerator scanner's; b) low radiation intensity - the radiation protection problem is much easier to solve and a lot of money can be saved on the radiation shielding building; c) much smaller area for installation and operation; d) simple operation and convenient maintenance; e) high reliability and stability. The Cobalt-60 container (or cargo) scanner is satisfied for boundary customs, seaports, airports and railway stations etc. Because of the nice special features said above, it is more suitable to be applied widely. Its high properties and low price will make it have much better application prospects

  2. Cobalt 60 commercial irradiation facilities

    International Nuclear Information System (INIS)

    West, G.

    1985-01-01

    The advantage of using cobalt 60 for ionizing treatment is that it has excellent penetration. Gamma plants are also very efficient, in as much as there is very little mechanical or electrical equipment in a gamma irradiation facility. The average efficiency of a gamma plant is usually around 95% of all available processing time

  3. Transport of cobalt-60 industrial radiation sources

    Science.gov (United States)

    Kunstadt, Peter; Gibson, Wayne

    This paper will deal with safety aspects of the handling of Cobalt-60, the most widely used industrial radio-isotope. Cobalt-60 is a man-made radioisotope of Cobalt-59, a naturally occurring non radioactive element, that is made to order for radiation therapy and a wide range of industrial processing applications including sterilization of medical disposables, food irradiation, etc.

  4. Cobalt 60 availability for radiation processing

    International Nuclear Information System (INIS)

    Fraser, F.M.

    1986-01-01

    In the last 20 years, the steady and significant growth in the application of radiation processing to industrial sterilization has been seen. The principal application of this technology is the sterilization of disposable medical products, food irradiation, the irradiation of personal care goods and so on. At present, more than 70 million curies of cobalt-60 supplied by Atomic Energy of Canada Ltd. have been used for gamma processing in these applications. This is estimated to be more than 80 % of the total cobalt-60 in service in the world. Commercial food irradiation has an exciting future, and as to the impact of food irradiation on the availability of cobalt-60 over the next ten years, two principal factors must be examined, namely, the anticipated demand for cobalt-60 in all radiation processing applications, and the supply of cobalt-60 to reliably meet the expected demand. As for the cobalt-60 in service today, 90 % is used for the sterilization of disposable medical products, 5 % for food irradiation, and 5 % for other application. The demand for up to 30 million curies of cobalt-60 is expected over the next 10 years. Today, it is estimated that over 150,000 tons of spices, fruit and fish are irradiated. The potential cobalt-60 production could exceed 110 million curies per year. Gamma processing application will demand nearly 50 million curies in 1990. (Kako, I.)

  5. Cobalt-60 production in CANDU reactors

    International Nuclear Information System (INIS)

    Ross, Michel; Lemire, Christian

    2002-01-01

    CANDU reactors can produce cobalt-60 very efficiently and with an interesting return on investment. This paper discusses what is needed to convert a CANDU reactor into a cobalt-60 producer: what are the different phases, the safety studies required, the physical modifications needed, and what is the minimum involvement of the utility owning the plant. The past ten years of experience of Hydro-Quebec as a cobalt-60 producer will be reviewed, including the management of the risk of both incident and electricity generation loss, and including the benefits for the utility and its personnel. Originally a simple metal used for centuries as a pigment, cobalt-59 today is transformed into cobalt-60, a radioactive element of unprecedented value. Well known in medicine for cancer treatment, cobalt-60 is also used to sterilize a wide range of disposable medical products used in hospitals and to sanitize pharmaceutical and cosmetic products. Cobalt-60 is proving to be a new and effective solution, in the food sector, for preserving harvests and controlling food-borne diseases, or to advantageously replace certain gases and chemical products which are suspected of being harmful or carcinogenic. There are also other applications, such as: hardening of some plastics, treatment of sewage sludge and elimination of harmful insect populations. With a half-life of 5,3 years, cobalt-60 is a metal not found in nature. It is a radioactive isotope produced by exposing stable nuclei of cobalt-59 to neutrons. One of the best places to find such an important neutron source is a nuclear reactor. High energy gamma rays are then emitted during the process of radioactive decay, where cobalt-60 seeks again its stable state

  6. Cobalt-60 production in CANDU power reactors

    International Nuclear Information System (INIS)

    Slack, J.; Norton, J.L.; Malkoske, G.R.

    2003-01-01

    MDS Nordion has been supplying cobalt-60 sources to industry for industrial and medical purposes since 1946. These cobalt-60 sources are used in many market and product segments. The major application is in the health care industry where irradiators are used to sterilize single use medical products. These irradiators are designed and built by MDS Nordion and are used by manufacturers of surgical kits, gloves, gowns, drapes and other medical products. The irradiator is a large shielded room with a storage pool for the cobalt-60 sources. The medical products are circulated through the shielded room and exposed to the cobalt-60 sources. This treatment sterilizes the medical products which can then be shipped to hospitals for immediate use. Other applications for this irradiation technology include sanitisation of cosmetics, microbial reduction of pharmaceutical raw materials and food irradiation. The cobalt-60 sources are manufactured by MDS Nordion in their Cobalt Operations Facility in Kanata. More than 75,000 cobalt-60 sources for use in irradiators have been manufactured by MDS Nordion. The cobalt-60 sources are double encapsulated in stainless steel capsules, seal welded and helium leak tested. Each source may contain up to 14,000 curies. These sources are shipped to over 170 industrial irradiators around the world. This paper will focus on the MDS Nordion proprietary technology used to produce the cobalt-60 isotope in CANDU reactors. Almost 55 years ago MDS Nordion and Atomic Energy of Canada developed the process for manufacturing cobalt-60 at the Chalk River Labs, in Ontario, Canada. A cobalt-59 target was introduced into a research reactor where the cobalt-59 atom absorbed one neutron to become cobalt-60. Once the cobalt-60 material was removed from the research reactor it was encapsulated in stainless steel and seal welded using a Tungsten Inert Gas weld. The first cobalt-60 sources manufactured using material from the Chalk River Labs were used in cancer

  7. Cobalt-60 production in CANDU power reactors

    International Nuclear Information System (INIS)

    Malkoske, G.R.; Norton, J.L.; Slack, J.

    2002-01-01

    MDS Nordion has been supplying cobalt-60 sources to industry for industrial and medical purposes since 1946. These cobalt-60 sources are used in many market and product segments, but are primarily used to sterilize single-use medical products including; surgical kits, gloves, gowns, drapes, and cotton swabs. Other applications include sanitization of cosmetics, microbial reduction of pharmaceutical raw materials, and food irradiation. The technology for producing the cobalt-60 isotope was developed by MDS Nordion and Atomic Energy of Canada Limited (AECL) almost 55 years ago using research reactors at the AECL Chalk River Laboratories in Ontario, Canada. The first cobalt-60 source produced for medical applications was manufactured by MDS Nordion and used in cancer therapy. The benefits of cobalt-60 as applied to medical product manufacturing, were quickly realized and the demand for this radioisotope quickly grew. The same technology for producing cobalt-60 in research reactors was then designed and packaged such that it could be conveniently transferred to a utility/power reactor. In the early 1970's, in co-operation with Ontario Power Generation (formerly Ontario Hydro), bulk cobalt-60 production for industrial irradiation applications was initiated in the four Pickering A CANDU reactors. As the demand and acceptance of sterilization of medical products grew, MDS Nordion expanded its bulk supply by installing the proprietary Canadian technology for producing cobalt-60 in additional CANDU reactors. CANDU is unique among the power reactors of the world, being heavy water moderated and fuelled with natural uranium. They are also designed and supplied with stainless steel adjusters, the primary function of which is to shape the neutron flux to optimize reactor power and fuel bum-up, and to provide excess reactivity needed to overcome xenon-135 poisoning following a reduction of power. The reactor is designed to develop full power output with all of the adjuster

  8. An elevator for cobalt-60 source

    International Nuclear Information System (INIS)

    Tang Zaimin; Liang Donghu

    1990-07-01

    The elevator used for cobalt-60 source is a key device in the irradiation industry. It plays an important role in the safety and control of irradiation operation as well as the utilization rate of radiation source. From 1983 to 1986, Beijing Institute of Nuclear Engineering undertook designing of various size irradiation projects for different uses. Since then a kind of cobalt-60 source elevator suited for the irradiator of wet-source-storage has been chosen. It is reliable in the operation and complete in the function. An automatic control circuit brings the systems of cobalt-60 source elevator into an interlock system which ensures the irradiation operation safety. Besides introducing the structural features and performance of this elevator, the conditions of safety interlocking in raising or lowering the cobalt-60 source is also discussed. The discussion is from the safety viewpoint of operating an irradiator and irradiation technology

  9. Cobalt-60 control in Ontario Hydro reactors

    International Nuclear Information System (INIS)

    Lacy, C.S.

    1988-01-01

    This paper discusses the impact of specifying reduced Cobalt-59 in the primary heat transport circuit materials of construction on the radiation fields developed around the primary circuit. An eight-fold reduction in steam generator radiation fields due to Cobalt-60 has been observed for two identical sets of reactors, one with and one without Cobalt-59 control. The comparison is between eight reactors at the Pickering Nuclear Generating Station (PNGS). Units 5 to 8 (PNGS-B) are identical to Units 1 to 4 (PNGS-A) except that PNGS-B has reduced impurity Cobalt-59 in the alloys of construction and a reduced use of stellite. The effects of chemistry control are also discussed

  10. Total quality management of cobalt-60 sources

    International Nuclear Information System (INIS)

    Malkoske, G.R.

    1999-01-01

    Total Quality Management of Cobalt-60 sources by a supplier requires a life cycle approach to source management. This covers various aspects, including design, manufacturing, installation, field inspection, source surveillance and return of cobalt-60 sources at the end of their useful life. The Total Quality Management approach demonstrates a strong industry commitment to the beneficial use of gamma technology for industrial irradiation applications in both developed nations and in those nations who are developing their infrastructure and techniques for the beneficial use of this technology. MDS Nordion continues to demonstrate its support and commitment to the industry by developing and implementing state-of-the-art standards for the safe use of cobalt-60 sources

  11. Cobalt60 plaques in recurrent retinoblastoma

    Energy Technology Data Exchange (ETDEWEB)

    Fass, D.; McCormick, B.; Abramson, D.; Ellsworth, R. (Department of Radiation Oncology, Memorial Sloan-Kettering Cancer Center, NY, NY (USA))

    1991-08-01

    Cobalt60 plaque irradiation is one treatment option for patients with recurrent retinoblastoma following conventional external beam irradiation (ERT). Tumorocidal doses can be delivered without excessive risk of normal tissue injury. In patients not considered candidates for xenon arc or cryotherapy, 60Co is an alternative to enucleation. Between 1968 and 1987, 85 patients were treated with 60Co plaques, 72 of whom had failed prior ERT. Age at diagnosis ranged from 1 week to 4 years. There are 37 males and 35 females. Seventy-one patients had bilateral disease and one had unilateral. Three patients had both eyes plaqued. Prior ERT ranged from 30 to 70 Gy (mean 4200 Gy). Time from initial therapy to failure ranged from 13 to 60 months. Cobalt plaques of 10 mm, 15 mm, or 10 {times} 15 mm were used depending on tumor size and location. Dose prescribed to the apex of the tumor ranged from 30 to 50 Gy (median 40 Gy) given over 3 to 8 days. Twelve patients had two plaque applications; three patients had three plaque applications. All patients were followed with routine ophthalmoscopic examinations. Follow-up ranged from 2 to 22 years (mean 8.7). Seven patients died of metastatic disease; 10 patients developed non-ocular second tumors. Thirty patients required enucleation. Twenty-two patients had clear tumor progression, two patients had radiation complications, and six patients had a combination of tumor growth and complications. Cobalt60 can salvage eyes in retinoblastoma patients failing ERT. Currently, the authors are using I125 in an attempt to spare normal ocular tissue and reduce subsequent complications.

  12. Cobalt60 plaques in recurrent retinoblastoma

    International Nuclear Information System (INIS)

    Fass, D.; McCormick, B.; Abramson, D.; Ellsworth, R.

    1991-01-01

    Cobalt60 plaque irradiation is one treatment option for patients with recurrent retinoblastoma following conventional external beam irradiation (ERT). Tumorocidal doses can be delivered without excessive risk of normal tissue injury. In patients not considered candidates for xenon arc or cryotherapy, 60Co is an alternative to enucleation. Between 1968 and 1987, 85 patients were treated with 60Co plaques, 72 of whom had failed prior ERT. Age at diagnosis ranged from 1 week to 4 years. There are 37 males and 35 females. Seventy-one patients had bilateral disease and one had unilateral. Three patients had both eyes plaqued. Prior ERT ranged from 30 to 70 Gy (mean 4200 Gy). Time from initial therapy to failure ranged from 13 to 60 months. Cobalt plaques of 10 mm, 15 mm, or 10 x 15 mm were used depending on tumor size and location. Dose prescribed to the apex of the tumor ranged from 30 to 50 Gy (median 40 Gy) given over 3 to 8 days. Twelve patients had two plaque applications; three patients had three plaque applications. All patients were followed with routine ophthalmoscopic examinations. Follow-up ranged from 2 to 22 years (mean 8.7). Seven patients died of metastatic disease; 10 patients developed non-ocular second tumors. Thirty patients required enucleation. Twenty-two patients had clear tumor progression, two patients had radiation complications, and six patients had a combination of tumor growth and complications. Cobalt60 can salvage eyes in retinoblastoma patients failing ERT. Currently, the authors are using I125 in an attempt to spare normal ocular tissue and reduce subsequent complications

  13. Cobalt-60 gamma irradiation of shrimp

    International Nuclear Information System (INIS)

    Sullivan, N.L.B.

    1993-01-01

    Meta- and ortho-tyrosine were measured using high performance liquid chromatography (HPLC) in conjunction with electrochemical detection in shrimp irradiated using cobalt-60 gamma radiation in the absorbed dose range 0.8 to 6.0 kGy, in nonirradiated shrimp, and in bovine serum albumin (BSA) irradiated in dilute aqueous solution at 25.0 kGy. Ortho-tyrosine was measured in nonirradiated BSA. Para-, meta-, and ortho-tyrosine was measured using HPLC in conjunction with uv-absorption detection in dilute aqueous solutions of phenylalanine irradiated in the absorbed dose range 16.0 to 195.0 kGy. The measured yields of tyrosine isomers were approximately linear as a function of absorbed dose in shrimp, and in irradiated solutions of phenylalanine up to 37.0 kGy. The occurrence of meta- and ortho-tyrosine, which had formerly been considered unique radiolytic products, has not previously been reported in nonirradiated shrimp or BSA. The conventional hydrolyzation and analytical techniques used in the present study to measure meta- and ortho-tyrosine may provide the basis for a method to detect and determine the dose used in food irradiation

  14. Cobalt 60 cation exchange with mexican clays

    International Nuclear Information System (INIS)

    Nava Galve, R.G.

    1993-01-01

    Mexican clays can be used to remove radioactive elements from contaminated aqueous solutions. Cation exchange experiments were performed with 60 Co radioactive solution. In the present work the effect of contact time on the sorption of Co 2+ was studied. The contact time in hydrated montmorillonite was from 5 to 120 minutes and in dehydrated montmorillonite 5 to 1400 minutes. The Co 2+ uptake value was, in hydrated montmorillonite, between 0.3 to 0.85 m eq/g and in dehydrated montmorillonite, between 0.6 to 1.40 m eq/g. The experiments were done in a pH 5.1 to 5.7 and normal conditions. XRD patterns were used to characterize the samples. The crystallinity was determined by X-ray Diffraction and it was maintained before and after the cation exchange. DTA thermo grams showed the temperatures of the lost humidity and crystallization water. Finally, was observed that dehydrated montmorillonite adsorb more cobalt than hydrated montmorillonite. (Author)

  15. Activation of cobalt 60 in the LVR-15 reactor core

    International Nuclear Information System (INIS)

    Melichar, F.

    1995-12-01

    Cobalt disks were irradiated in the LVR-15 reactor and the relevant cobalt-60 production parameters, particularly the formation rate, were measured. The data were compared with those from previous work by other authors and some discrepancies were found. It is concluded that additional experiments have to be performed in order to obtain reliable data, usable in economic balance assessment with respect to the use of hot chambers for the production of sealed cobalt-60 sources. (P.A.). 4 tabs., 3 refs., 10 annexes

  16. Cobalt-60 production in the BN-350 fast power reactor

    International Nuclear Information System (INIS)

    Zvonarev, A.V.; Korobejnikov, V.V.; Matveenko, I.P.

    1994-01-01

    A possibility of Co-60 isotope production in the BN-350 fast reactor was considered. A special irradiating device, which is an assembly with a central hole, where a container containing cobalt and zirconium hydride is placed. The irradiating device tested permits generating 60 Co with specific activity of 100 Ci/g

  17. Effects of bathing on skin exposed to Cobalt-60 teletherapy

    International Nuclear Information System (INIS)

    Bohannan, P.A.

    1982-01-01

    The problem of this study was to determine the effects of bathing or not bathing on the degree of skin reaction occurring in patients receiving Cobalt-60 radiation therapy to the chest, back, or head and neck. A quasi experimental study was done using a 2 x 7 repeated measures design. Sixty-seven subjects receiving Cobalt-60 radiation therapy at the Moncrief Radiation Center in Fort Worth, Texas, were randomly assigned to an experimental group who did not bathe during therapy and a control group who did bathe with water during therapy. Observations were made after each 1000 rads of therapy and two weeks after the final treatment. Erythema and pigmentation measurements were taken using the Photovolt 670 and rates were assigned using the Baker-Leith Rating Scale. Findings from the study suggest that bathing the portal of entry with water during the treatment period does not influence the degree of skin response that occurs from Cobalt-60 teletherapy

  18. C-188 cobalt-60 sealed source integrity: source monitoring

    International Nuclear Information System (INIS)

    Defalco, G.M.; Shah, V.

    1995-01-01

    The integrity of C-188 cobalt-60 sealed sources used for radiation processing will be a key factor in the continued industrial acceptance and growth of gamma irradiation technology. Given the public's relatively poor understanding of most nuclear topics and the news media's tendency to sensationalize events, it is appropriate for suppliers and users of gamma technology to be vigilant and conservative regarding the application of cobalt-60 sources to industrial purposes. Nordion's recent decision to extend the optional warranty on its C-188 cobalt-60 sealed source from 15 years to 20 years is based on over 30 years of data generated from its on-going SOURCE SURVEILLANCE PROGRAM. This paper presents an overview of the C-188 SOURCE SURVEILLANCE PROGRAM. (author)

  19. Cobalt 60 gamma irradiation current status, trends and insights

    International Nuclear Information System (INIS)

    Corley, John T.

    1998-01-01

    This paper discusses the current status, trends and insights into the continued, safe use of cobalt 60 gamma irradiation. Also presented are some of the many initiatives undertaken at MDS Nordion. Topics covered include our investment for the future supply of raw materials and the latest news from source production. Briefly presented are the tasks associated with the safe transport of cobalt 60 around the world. Discussed is cobalt 60 usage at the customer site; more specifically maintaining source integrity, source utilization and irradiator design trends. Highlighted are industry trends for North America, Europe and the rest of the world. Finally presented are the challenges and opportunities for the industry. Stressed in the paper is the need to work together

  20. Investigation of the production of cobalt-60 via particle accelerator

    Directory of Open Access Journals (Sweden)

    Artun Ozan

    2017-01-01

    Full Text Available The production process of cobalt-60 was simulated by a particle accelerator in the energy range of 5 to 100 MeV, particle beam current of 1 mA, and irradiation time of 1 hour to perform yield, activity of reaction, and integral yield for charged particle-induced reactions. Based on nuclear reaction processes, the obtained results in the production process of cobalt-60 were also discussed in detail to determine appropriate target material, optimum energy ranges, and suitable reactions.

  1. Cobalt-60 in the treatment of cancer-future scenario

    International Nuclear Information System (INIS)

    Sastri, K.V.S.; Patil, B.N.; Kohli, A.K.

    2009-01-01

    Treatment of cancer using radiation is established method. Cobalt-60 is the workhorse of cancer treatment from the beginning. Later linear accelerators with more accessories were developed and are now used for the advanced treatments like IMRT, IGRT etc. Gammaknife, Gyroknife and supergamma machines using 60 Co have also taken roots for the treatment of cancer. The use of 60 Co in the treatment of cancer is expected to continue for some more time to come. (author)

  2. New avenues in cobalt-60 production at Ontario Hydro

    International Nuclear Information System (INIS)

    Mylvaganam, C.K.; Ronchka, R.A.

    1990-01-01

    Ontario Hydro produces cobalt-60 in the control rods of twelve power reactors. These reactors have a typical flux of 2 x 10 14 neutrons/cm 2 /s, making them efficient producers of cobalt-60. Current annual production is 45 million curies. Since the primary function of these reactors is the production of electricity, their flexibility to meet the needs of commercial cobalt production by the control rod route is limited. Ontario Hydro is therefore developing innovative production techniques, making use of the CANDU reactor's unique ability to be fuelled on-power. These techniques will enable production to better respond to the market's requirements for quantity and specific activity. As it is supplementary to control rod production, annual supply could potentially reach 165 million curies. (author)

  3. Ultrasonography-guided cobalt-60 brachytherapy for malignant glioma

    International Nuclear Information System (INIS)

    Sakai, Noboru; Takenaka, Katsunobu; Ueda, Tatsuya

    1989-01-01

    Brachytherapy with cobalt-60 source is reported. In this method it is characterized that the source is inserted interstitially with remote control system by after-loading method via outer catheter (using tandem tube), which was established in the center of residual tumor, using ultrasonography guide with trepanation, or intraoperatively put within the dead space after tumor resection. Six cases of deep-seated and recurrent malignant glioma, were treated with this method. A total dose of 20 to 45 Gy (10 to 15 Gy/day for 2 to 3 days) was delivered to the target. Additionally conventional external irradiation was followed. The effect of cobalt-60 brachytherapy on such tumors were favorable especially for well-circumscribed glioma less than 3 cm on CT scan. (author)

  4. Consumer products polluted by cobalt-60 on the Dutch market

    International Nuclear Information System (INIS)

    Bothof, J.

    2002-01-01

    In several previous articles of this magazine attention has been paid to reporting of radioactive materials in scrap metals and incidents with radioactive materials, which were dealt with by the VROM-Inspectie Regio Zuid-West (Inspection for the Region South-West in the Netherlands). In this article attention is paid to a special incident with new stainless steel flanges, polluted by cobalt 60 [nl

  5. Nationwide survey of cobalt-60 teletherapy. Final report

    International Nuclear Information System (INIS)

    Thompson, D.L.; Kearly, F.E.; Wyckoff, H.O.; Gitlin, J.N.; Reffit, E.B.; Shangold, E.J.

    1980-08-01

    The Bureau of Radiological Health and the National Bureau of Standards conducted a nationwide survey of cobalt-60 teletherapy facilities to determine their accuracy in delivery of a prescribed dose to a phantom. Participation was obtained from 684 respondents or 75 percent of US facilities. For each cobalt-60 unit the average dose recorded on five dosimeters was within 5 percent of the prescribed value for 83 percent of the respondents and only exceeded a 10 percent difference for 3 percent of the respondents. Sufficient information for reconstruction of dose calculations was available for 87 percent of the participating facilities. Of these reconstructed calculations, 56 percent were within 1 percent of the prescribed dose of 300 rads. The analysis of data from the survey showed that better performance were related to a number of factors. Among these were expressing the machine calibration in terms of dose rate, performing the machine calibration on an annual basis, and correcting for source decay on a monthly basis. Larger facilities achieved better results than smaller facilities when calculating the absorbed dose rate. Also, each 4 machine characteristics (isocentric mounting, short exposure time, high normalized output, and long treatment distance) were related to better performance with regard to both dosimeter readings and calculated doses. Larger facilities were more likely to be using a cobalt-60 unit having those characteristics

  6. Absolute exposure determination of cobalt-60 gamma radiation

    International Nuclear Information System (INIS)

    Ahmad, S.S.; Ali, A.; Orfi, S.D.

    1986-02-01

    The report describes the procedure for the determination of absolute exposure for Cobalt-60 gamma radiation. A graphite cavity chamber, nominal volume of 1 cm 3 , manufactured by Austrian Research Centre Seibersdorf has been used. The exposure rate at reference distance determined with the graphite chamber was compared with mean exposure rate measured with NPL-Therapy level X-ray exposure meter normalized to same date. An agreement of 0.39% was found between the two measuring systems, which seems to be very encouraging and quite satisfactory. (authors)

  7. Economics of gamma processing in cobalt-60 irradiation facilities

    International Nuclear Information System (INIS)

    Gay, H. G.; Kotler, J. G.

    1985-01-01

    Gamma processing by cobalt-60 is well established. However, since irradiation of food is relatively new from the commercial point of view, it is important to assess costs of gamma irradiation in the context of food processing. Five different types of AECL-RCC irradiation equipment are examined in terms of their throughputs, and capital and operating costs. Using these figures, costs of irradiation of nine types of food products are presented. In general, these represent about 2-10% of the wholesale cost of these products

  8. Cobalt

    International Nuclear Information System (INIS)

    Stolyarova, I.A.; Bunakova, N.Yu.

    1983-01-01

    The neutron-activation method for determining cobalt in rocks, polymetallic and iron ores and rockforming minerals at 2x10 -6 -5x10 -3 % content is developed. Cobalt determination is based on the formation under the effect of thermal neutrons of nuclear reactor of the 60 Co radioactive isotope by the 59 Co (n, γ) 60 Co reaction with radiation energy of the most intensive line of 1333 keV. Cobalt can be determined by the scheme of the multicomponent analysis from the sample with other elements. Co is determined in the solution after separation of all determinable by the scheme elements. The 60 Co intensity is measured by the mUltichannel gamma-spectrometer with Ge(Li)-detector

  9. Activity distribution of a cobalt-60 teletherapy source

    International Nuclear Information System (INIS)

    Jaffray, D.A.; Munro, P.; Battista, J.J.; Fenster, A.

    1991-01-01

    In the course of quantifying the effect of radiation source size on the spatial resolution of portal images, a concentric ring structure in the activity distribution of a Cobalt-60 teletherapy source has been observed. The activity distribution was measured using a strip integral technique and confirmed independently by a contact radiograph of an identical but inactive source replica. These two techniques suggested that this concentric ring structure is due to the packing configuration of the small 60Co pellets that constitute the source. The source modulation transfer function (MTF) showed that this ring structure has a negligible influence on the spatial resolution of therapy images when compared to the effect of the large size of the 60Co source

  10. Development and production of cobalt-60 sources for metallurgical application

    International Nuclear Information System (INIS)

    Oliveira, Paulo Fernando; Valente, Eduardo Sarmento; Maretti Junior, Fausto

    2002-01-01

    The CDTN has developed and produced 60 Co sources to be used in level controllers on continuous ingot casting. The sources used in these systems are sealed with a stainless steel revetment and have an useful life equivalent to one half life of the 60 Co (5.272 years). Each system of continuous ingot casting uses a source with one specified activity and different activation section. The sources have been imported with a very high cost due the special shields used to keep and transport them safety. One of its sources, with initial activity of 148 MBq, after being used for more than 5 years in one factory, was given to CDTN to carry out an activation section studies. After these studies be concluded CDTN/CNEN began the procedures to produce a new source in the IPR-R1 TRIGA Reactor, with an irradiation of one cobalt wire in the maximum flux region of the core. The same metallic cobalt wire was irradiated (10% of total activity), to determinate the necessary irradiation time to obtain the final activation. The CDTN developed too a stainless steel recipient with a aluminum nucleus, to seal and to guarantee the integrity of the source. (author)

  11. An Economic Analysis of Electron Accelerators and Cobalt-60 for Irradiating Food

    OpenAIRE

    Morrison, Rosanna Mentzer

    1989-01-01

    Average costs per pound of irradiating food are similar for the electron accelerator and cobalt-60 irradiators analyzed in this study, but initial investment costs can vary by $1 million. Irradiation costs range from 0.5 to 7 cents per pound and decrease as annual volumes treated increase. Cobalt-60 is less expensive than electron beams for annual volumes below 50 million pounds. For radiation source requirements above the equivalent of 1 million curies of cobalt-60, electron beams are more e...

  12. PENYERAPAN COBALT-60 DARI AIR OLEH TANAMAN KIAPU (Pistia stratiotes L.)

    OpenAIRE

    Lailatul Nuzzulul Safitri; Poppy Intan Tjahaja; Ida Bagus Made Suryatika

    2015-01-01

    Has conducted research Cobalt-60 radionuclide uptake by plants kiapu (Pistia stratiotes L.) found in many waters. The purpose of the study was to determine the value of the transfer factor on plant kiapu to Cobalt-60 in water. The study was conducted by growing plants on media kiapu gutter water in pots with the height 35 cm and diameter 11,5 cm containing Cobalt-60. The amount of Cobalt - 60 is absorbed and accumulated by the plant parts, i.e. roots and leaves, was observed by measuring the ...

  13. Research about combination of Gamma Knife and cobalt-60 radiation therapy to treat hypophysoma

    International Nuclear Information System (INIS)

    Xing Yueming; Zhao Xinping; Song Xiang; Wu Wei; Huang Bai

    2003-01-01

    Objective: To probe the therapeutic effectiveness of combination of Gamma Knife and cobalt-60 radiotherapy. Methods: 80 Hypophysoma patients who have been randomly grouped into two groups. Combination of Gamma Knife and cobalt-60 radiotherapy group and single Gamma knife group. Results: The therapeutic effectiveness of combination of Gamma Knife and cobalt-60 radiation therapy group was higher than that of single Gamma Knife group. Conclusion: The hospital that treat Hypophysoma with single Gamma Knife should add cobalt-60 radiotherapy in order to increase the local Hypophysoma dose

  14. Cobalt Blues The Story of Leonard Grimmett, the Man Behind the First Cobalt-60 Unit in the United States

    CERN Document Server

    Almond, Peter R

    2013-01-01

    For the latter half of the 20th century, cobalt-60 units were the mainstay of radiation treatments for cancer. Cobalt Blues describes the development of the first cobalt-60 unit in the United States and the man behind it, Leonard Grimmett. Conceptually conceived before World War II, it only became possible because of the development of nuclear reactors during the war. Although Grimmett conceived of and published his ideas first, the Canadians built the first units because of the capability of their reactor to produce more suitable cobalt-60 sources. This book tells the story of how Grimmett and others came together at the time that the U S Atomic Energy Agency was pushing the use of radioactivity in medicine. Due to his sudden death, very little information about Grimmett was known until recently, when various documents have come to light, allowing the full story to be told.

  15. SSDL Argentina: Dosimetric intercomparison programme for cobalt 60 therapy units

    Energy Technology Data Exchange (ETDEWEB)

    Saravi, M; Papadopulos, S; Mugliaroli, H [Comision Nacional de Energia Atomica, Buenos Aires (Argentina)

    1996-08-01

    Thermoluminescence dosimeters (TLD) are widely used to verify absorbed dose delivered from radiation therapy beams. The Secondary Standard Dosimetry Laboratory (SSDL) of Argentina uses TLD for its mailed dose intercomparison programme for cobalt 60 radiation therapy units. Results obtained since 1978 as well as causes of dose discrepancies greater than 5% are analyzed. Results of the external quality control performed by the IAEA for this programme indicate that the dose evaluated by the SSDL TLD service for the participating centers is about 1% lower than that evaluated by the IAEA TLD service. This deviation is accepted taking on account that a {+-} 2% dose uncertainty for TLD dosimetry is reasonable. (author). 5 refs, 5 figs, 2 tabs.

  16. Practical and clinical considerations in Cobalt-60 tomotherapy

    Directory of Open Access Journals (Sweden)

    Joshi Chandra

    2009-01-01

    Full Text Available Cobalt-60 (Co-60 based radiation therapy continues to play a significant role in not only developing countries, where access to radiation therapy is extremely limited, but also in industrialized countries. Howver, technology has to be developed to accommodate modern techniques, in-clud-ing image guided and adaptive radiation therapy (IGART. In this paper we describe some of the practical and clinical considerations for Co-60 based tomotherapy by comparing Co-60 and 6 MV linac-based tomotherapy plans for a head and neck (HandN cancer and a prostate cancer case. The tomotherapy IMRT plans were obtained by modeling a MIMiC binary multi-leaf collimator attached to a Theratron-780c Co-60 unit and a 6 MV linear accelerator (CL2100EX. The EGSnrc/BEAMnrc Monte Carlo (MC code was used for the modeling of the treatment units with the MIMiC collimator and EGSnrc/DOSXYZnrc code was used for beamlet dose data. An in-house inverse treatment planning program was then used to generate optimized tomotherapy dose distributions for the H and N and prostate cases. The dose distributions, cumulative dose area histograms (DAHs and dose difference maps were used to evaluate and compare Co-60 and 6 MV based tomotherapy plans. A quantitative analysis of the dose distributions and dose-volume histograms shows that both Co-60 and 6 MV plans achieve the plan objectives for the targets (CTV and nodes and OARs (spinal cord in HandN case, and rectum in prostate case.

  17. New formula for calculation of cobalt-60 percent depth dose

    International Nuclear Information System (INIS)

    Tahmasebi Birgani, M. J.; Ghorbani, M.

    2005-01-01

    On the basis of percent depth dose calculation, the application of - dosimetry in radiotherapy has an important role to play in reducing the chance of tumor recurrence. The aim of this study is to introduce a new formula for calculating the central axis percent depth doses of Cobalt-60 beam. Materials and Methods: In the present study, based on the British Journal of Radiology table, nine new formulas are developed and evaluated for depths of 0.5 - 30 cm and fields of (4*4) - (45*45) cm 2 . To evaluate the agreement between the formulas and the table, the average of the absolute differences between the values was used and the formula with the least average was selected as the best fitted formula. The Microsoft Excel 2000 and the Data fit 8.0 soft wares were used to perform the calculations. Results: The results of this study indicated that one amongst the nine formulas gave a better agreement with the percent depth doses listed in the table of British Journal of Radiology . The new formula has two parts in terms of log (A/P). The first part as a linear function with the depth in the range of 0.5 to 5 cm and the other one as a second order polynomial with the depth in the range of 6 to 30 cm. The average of - the differences between the tabulated and the calculated data using the formula (Δ) is equal to 0.3 152. Discussion and Conclusion: Therefore, the calculated percent depth dose data based on this formula has a better agreement with the published data for Cobalt-60 source. This formula could be used to calculate the percent depth dose for the depths and the field sizes not listed in the British Journal of Radiology table

  18. A laboratory and field evaluation of the mobility of cobalt-60/EDTA

    International Nuclear Information System (INIS)

    Jones, T.L.; Gee, G.W.; Kirkham, R.R.; Swanson, J.L.

    1983-01-01

    We have observed a time and soil type dependence in the ability of the organic complexant EDTA to keep cobalt-60 in solution. Test results indicate that short-term adsorption tests lasting 5 days or less can be misleading. In short-term tests using cobalt-60/EDTA and soil from the Hanford site, low sorption in batch tests and high mobility in column tests were observed. During long-term batch test using cobalt-60/EDTA, the percentage of cobalt remaining in solution decreased from 90% after 7 days to less than 10% after 500 days. In laboratory and field column tests where low water flow rates allowed long contact time, virtually no cobalt movement was observed even though in the field test tritium was transported over 4 meters. Long-term batch tests using cobalt-60/EDTA and soil from Savannah River burial grounds showed that cobalt remainin in solution dropped to 30% of the total cobalt added after 5 days and to less than 1% after 15 days. Batch tests using soil from Oak Ridge burial grounds were less dramatic showing cobalt in solution decreasing from 90% after 5 days to 70% after 35 days. The cobalt-60/EDTA complex appears to be dissociating and leaving uncomplexed cobalt which is readily sorbed. The dissociation seems to be rather complete in Hanford and Savannah River soil but limited in the Oak Ridge soil. The implication to waste management is that the potential for transport of cobalt by EDTA may not be as serious at all burial sites as once thought

  19. Some safety aspects during the replacement of Cobalt-60 sources in teletherapy

    International Nuclear Information System (INIS)

    Milu, C.

    1998-01-01

    Some recent radiation protection problems arose during the replacement of the old Cobalt-60 sources in teletherapy in Romania. There are pointed out the potential radiation risks for the population and the lack of appropriate regulation for the field. (author)

  20. Process of contamination of two trophic dulcaquicole chains by cobalt 60. I

    International Nuclear Information System (INIS)

    Amiard-Triquet, C.; Foulquier, L.

    1978-01-01

    In order to evaluate Cobalt 60 behavior in freshwater ecosystems, two food chains including different nutritionally interdependent species in a natural environment were defined. This article covers the dynamics of water-borne contamination in the species. (Auth.)

  1. Calculation support for industrial production of cobalt-60 at Leningrad NPP

    International Nuclear Information System (INIS)

    Artemov, Vladimir; Elshin, Alexander; Ivanov, Alexander; Gorbunov, Evgeny; Ikonnikov, Roman; Pimenov, Alexander

    2008-01-01

    Cobalt-60 is industrially produced at the Leningrad NPP by irradiation of cobalt-59 in special-purpose facilities loaded into the RBMK reactor core (all 4 units). The paper describes calculation methods used to determine the current activity of cobalt in irradiation assemblies for their timely unloading. The described peculiarities of core calculation model account for continuous refueling, overloading of irradiation assemblies and individual thermohydraulics in each channel under variation of reactor power. Fuel burnup in the core is calculated with a time step of about 24 hours. The resulting values for cobalt activity and uncertainties are presented in the paper as well. Deviation of calculated cobalt activity from measured activity is within the experimental accuracy of 10% (at confidence probability of 0.95). (authors)

  2. Model for cobalt 60/58 deposition on primary coolant piping in a boiling water reactor

    International Nuclear Information System (INIS)

    Dehollander, W.R.

    1979-01-01

    A first principles model for deposition of radioactive metals into the corrosion films of primary coolant piping is proposed. It is shown that the predominant mechanism is the inclusion of the radioactive species such as Cobalt 60 into the spinel structure of the corrosion film during the act of active corrosion. This deposition can occupy only a defined fraction of the available plus 2 valence sites of the spinel. For cobalt ions, this ratio is roughly 4.6 x 10 -3 of the total iron sites. Since no distinction is made between Cobalt 60, Cobalt 58, and Cobalt 59 in this process, the radioactivity associated with this inclusion is a function of the ratio of the radioactive species to the nonradioactive species in the water causing the corrosion of the pipe metal. The other controlling parameter is the corrosion rate of the pipe material. This can be a function of time, for example, and it shown that freshly descaled metal when exposed to the cobalt containing water can incorporate as much as 10 x 10 -3 cobalt ions per iron atom in the initial corrosion period. This has implications for the problem of decontaminating nuclear reactor piping. Equations and selected observations are presented without reference to any specifically identified reactor or utility, so as to protect any proprietary interest

  3. National Low-Level Waste Management Program Radionuclide Report Series: Volume 12, Cobalt-60

    Energy Technology Data Exchange (ETDEWEB)

    Adams, J.P.

    1995-06-01

    This report outlines the basic radiological and chemical characteristics of cobalt-60 ({sup 60}Co) and examines how these characteristics affect the behavior of {sup 60}Co in various environmental media, such as soils, groundwater, plants, animals, the atmosphere, and the human body. Discussions also include methods of {sup 60}Co production, waste types, and waste forms that contain {sup 60}Co. All cobalt atoms contain 27 protons (Z = 27) and various numbers of neutrons (typically N = 27 to 37 neutrons) within the atom`s nucleus. There is only one stable isotope of cobalt, namely {sup 59}Co. All other cobalt isotopes, including {sup 60}Co, are radioactive. The radioactive isotopes of cobalt have half-lives ranging from less than a second ({sup 54}Co-0.19 s) to 5.2 years ({sup 60}Co). The radioactive isotopes of cobalt are not a normal constituent of the natural environment and are generated as a result of human activities. The primary source of {sup 60}Co in the environment has been low-level radioactive waste material generated as a result of neutron activation of stable {sup 59}Co that is present in the structural components of nuclear reactor vessels. This isotope is also intentionally produced, usually in reactors but also to some degree in accelerators for industrial and medical uses, such as for radiation sources for cancer treatment and nondestructive testing of metals and welds. {sup 60}Co may enter the environment as a result of the activities associated with nuclear reactor operations and decommissioning and when industrial and medical sources are being used, manufactured, or disposed.

  4. National Low-Level Waste Management Program Radionuclide Report Series: Volume 12, Cobalt-60

    International Nuclear Information System (INIS)

    Adams, J.P.

    1995-06-01

    This report outlines the basic radiological and chemical characteristics of cobalt-60 ( 60 Co) and examines how these characteristics affect the behavior of 60 Co in various environmental media, such as soils, groundwater, plants, animals, the atmosphere, and the human body. Discussions also include methods of 60 Co production, waste types, and waste forms that contain 60 Co. All cobalt atoms contain 27 protons (Z = 27) and various numbers of neutrons (typically N = 27 to 37 neutrons) within the atom's nucleus. There is only one stable isotope of cobalt, namely 59 Co. All other cobalt isotopes, including 60 Co, are radioactive. The radioactive isotopes of cobalt have half-lives ranging from less than a second ( 54 Co-0.19 s) to 5.2 years ( 60 Co). The radioactive isotopes of cobalt are not a normal constituent of the natural environment and are generated as a result of human activities. The primary source of 60 Co in the environment has been low-level radioactive waste material generated as a result of neutron activation of stable 59 Co that is present in the structural components of nuclear reactor vessels. This isotope is also intentionally produced, usually in reactors but also to some degree in accelerators for industrial and medical uses, such as for radiation sources for cancer treatment and nondestructive testing of metals and welds. 60 Co may enter the environment as a result of the activities associated with nuclear reactor operations and decommissioning and when industrial and medical sources are being used, manufactured, or disposed

  5. Safety analysis report: packages cobalt-60 shipping cask (packaging of radioactive and fissile materials)

    International Nuclear Information System (INIS)

    Evans, J.E.; Langhaar, J.W.

    1973-07-01

    Safety Analysis Report DPSPU-73-124-1 replaces DPSPU-69-124-1 and Supplement 1 to permit shipment of 350,000 curies of 60 Co (maximum) in cobalt-60 shipping casks in compliance with 10 CFR Part 71, Packaging of Radioactive Materials for Transport

  6. Quality and security on the uses of cobalt 60 sources for industrial irradiators

    International Nuclear Information System (INIS)

    Desroches, J.

    1976-01-01

    The construction and operation of industrial irradiators using large quantities of cobalt 60 give rise to an important problem of security. The CEA Radioisotope Department which manufactures and sells sources of Co60 has created an insurance Quality System which insures the maximum of security for the user. (author)

  7. Preliminary feasibility study on production of cobalt-60 source for industrial irradiation

    International Nuclear Information System (INIS)

    Joo, Po Kook; Park, Kyung Bae; Ahn, Yun Soo; Lee, Jong Tai; Kim, Hark Rho

    1999-05-01

    As there is a high possible demand of industrial Co-60 source in the world market, feasibility study of a project was performed to produce and to export Co-60 sources, utilizing KEPCO's Wolsung NPP for irradiation of cobalt and KAERI's hot-cells for fabrication of cobalt sources. Main concerns of the study were to understand irradiation and fabrication (encapsulation) processes and to examine related technologies, required facilities and equipment. In particular, it was examined intensively if it would be possible to modify facilities around the reactor vessel of Wolsung NPP tp substantiate the related licensing in order to irradiate cobalt in the reactor. It is expected that once, if cooperation scheme with MDS Nordion of Canada is established, main issues such as modification of facilities, related licensing, raw material procurement and technology transfer for high quality product will be solved. In order to review overall feasibility of the project, present status and prospect of the world market was surveyed and various usages of cobalt sources were reviewed with emphasis on possible demand increase per usage. Food poisoning accidents are prevailing worldwide and food irradiation with cobalt sources is considered as a promising measure to prevent them and may bring forth high increase of cobalt sources demand in the world market. Preliminary economic feasibility was studied in conservation, evaluating roughly the investment and the operating cost based on materials from various information sources. (author)

  8. Key technology studies of GY-20 and GY-40 High-capacity cobalt-60 transport casks

    International Nuclear Information System (INIS)

    Liu Huifang; Zhang Xin

    2012-01-01

    GY-20 and GY-40 high-capacity cobalt-60 transport casks are used to transport cobalt-60 industrial irradiators and cobalt-60 bundles. The radioactive contents have special features of high-activity and high residual heat, so only a few countries such as Canada, England and Russia have design capacity. The key technologies and corresponding solutions were studied for the design and manufacture of the cask taking into account the structural, thermal, mechanics and shield requests. A series of tests prove that the cask structure design, design criteria for lead coating structure and quality control measurements are reasonable and effective, and the cask shield integrity can be ensured for all conditions. The casks have ability to transport high-activity sealed sources safely, and the design of cask satisfies the requirement of design code and standard. It can provide reference for other B type package. (authors)

  9. The role of Cobalt-60 in modern radiation therapy: Dose delivery and image guidance

    Directory of Open Access Journals (Sweden)

    Schreiner L

    2009-01-01

    Full Text Available The advances in modern radiation therapy with techniques such as intensity-modulated radiation therapy and image-guid-ed radiation therapy (IMRT and IGRT have been limited almost exclusively to linear accel-erators. Investigations of modern Cobalt-60 (Co-60 radiation delivery in the context of IMRT and IGRT have been very sparse, and have been limited mainly to computer-modeling and treatment-planning exercises. In this paper, we report on the results of experiments using a tomotherapy benchtop apparatus attached to a conventional Co-60 unit. We show that conformal dose delivery is possible and also that Co-60 can be used as the radiation source in megavoltage computed tomography imaging. These results complement our modeling studies of Co-60 tomotherapy and provide a strong motivation for continuing development of modern Cobalt-60 treatment devices.

  10. Cobalt

    Science.gov (United States)

    Slack, John F.; Kimball, Bryn E.; Shedd, Kim B.; Schulz, Klaus J.; DeYoung,, John H.; Seal, Robert R.; Bradley, Dwight C.

    2017-12-19

    Cobalt is a silvery gray metal that has diverse uses based on certain key properties, including ferromagnetism, hardness and wear-resistance when alloyed with other metals, low thermal and electrical conductivity, high melting point, multiple valences, and production of intense blue colors when combined with silica. Cobalt is used mostly in cathodes in rechargeable batteries and in superalloys for turbine engines in jet aircraft. Annual global cobalt consumption was approximately 75,000 metric tons in 2011; China, Japan, and the United States (in order of consumption amount) were the top three cobalt-consuming countries. In 2011, approximately 109,000 metric tons of recoverable cobalt was produced in ores, concentrates, and intermediate products from cobalt, copper, nickel, platinum-group-element (PGE), and zinc operations. The Democratic Republic of the Congo (Congo [Kinshasa]) was the principal source of mined cobalt globally (55 percent). The United States produced a negligible amount of byproduct cobalt as an intermediate product from a PGE mining and refining operation in southeastern Montana; no U.S. production was from mines in which cobalt was the principal commodity. China was the leading refiner of cobalt, and much of its production came from cobalt ores, concentrates, and partially refined materials imported from Congo (Kinshasa).The mineralogy of cobalt deposits is diverse and includes both primary (hypogene) and secondary (supergene) phases. Principal terrestrial (land-based) deposit types, which represent most of world’s cobalt mine production, include primary magmatic Ni-Cu(-Co-PGE) sulfides, primary and secondary stratiform sediment-hosted Cu-Co sulfides and oxides, and secondary Ni-Co laterites. Seven additional terrestrial deposit types are described in this chapter. The total terrestrial cobalt resource (reserves plus other resources) plus past production, where available, is calculated to be 25.5 million metric tons. Additional resources of

  11. Evaluation of skyshine dose due to gamma-rays from a cobalt-60 irradiation facility

    International Nuclear Information System (INIS)

    Kanazawa, Tamotsu; Okamoto, Shinichi; Ohnishi, Tokuhiro; Tsujii, Yukio

    1991-01-01

    We attempted to evaluate skyshine dose due to gamma-rays from a cobalt-60 irradiation facility. As the first step, the results of measurements and calculations were compared of the skyshine dose due to gamma-rays from the cobalt-60 source of 1.45 PBq set in the No.4 irradiation room of our laboratory. Distances of measuring points from the cobalt source were in the range from 17 m to about 100 m in the site of our office. Calculation was carried out with simplified single scattering method. The calculated values of the skyshine dose were higher than the measured values. For more precise evaluation of the skyshine dose, the following factors are to be considered; the dose rate distribution on the roof above the source and the attenuation of gamma-rays by air. (author)

  12. Sedimentation of cobalt-60 and caesium-137 released in Tvaeren, a Baltic bay

    International Nuclear Information System (INIS)

    Ramberg, L.

    1984-01-01

    The amounts of cobalt-60 and caesium-137 bound in the sediment in a bay off the Studsvik research station were determined. Of the cumulative released activity during 22 years, 19% of 60 Co and 1.8% of 137 Cs were found in the sediments within an area of 23 km 2 . The rate of input through sedimentation and the loss rate through physical decay were of the same order in 1981 and were close to steady state for 60 Co while for 137 Cs they had only reached 30% of that level. The sedimentation coefficients calculated for the bay were 6.5 year -1 for 60 Co and 0.49 year -1 for 137 Cs, higher values than many published previously. Cobalt-60 seemed to precipitate close to the outlet and to migrate near the bottom as bed-load. (author)

  13. Dose enhancement in a room cobalt-60 source

    International Nuclear Information System (INIS)

    Simons, M.; Pease, R.L.; Fleetwood, D.M.; Schwank, J.R.; Krzesniak, M.

    1997-01-01

    A room Co-60 source was characterized using TLDs and pMOS RADFETs. Dose enhancement was measured using RADFETs with and without gold- flashed kovar lids. A methodology was developed to predict dose enhancement vs position and test configuration

  14. Sorption behaviour of cobalt-60 on Suez Canal bottom sediments

    International Nuclear Information System (INIS)

    Abdel Gawad, S.A.; El-Shinawy, R.M.K.; Abdel Malik, W.E.Y.

    1981-01-01

    Mineralogical, elemental analysis and sorption behaviour of the Suez Canal bottom sediments in the Port Said area were investigated. It was found that the bottom sediment consist mainly of quartz, feldspars and traces of calcite mineral. The cation-exchange capacity was found to increase as the particle size of the sediment decreased. Sorption of 60 Co by the bottom sediment increased with contact time up to 6 h. Variation of the solution pH from 4 to 9 showed limited increase in the sorption of 60 Co. As carrier concentrations increase from 10 -7 N to 10 -3 N, sorption of Co was found to increase linearly following Freundlich isotherm. The presence of Mg 2+ and Fe 3+ in solution depressed the sorption of 60 Co by the sediments. The desorption of 60 Co from bottom sediment with distilled and Suez Canal water was found to increase with contact time. (author)

  15. Effect of the gamma radiation of cobalt 60 on the beta carotids present in the carrot

    International Nuclear Information System (INIS)

    Perez Lopez, Sergio Victor Hugo

    1997-01-01

    In the present work it was investigated the effect of the gamma radiation of cobalt 60 on the beta carotid's in the carrot (daucus carota), using for it three different radiation dose (100, 150 and 200 kilo-rad) and analyzing them by means of the liquid chromatography technique of high resolution (HPLC)

  16. Point kernel technique for calculating dose rates due to cobalt-60 hot particles

    International Nuclear Information System (INIS)

    Thornhill, M.J.; McCarthy, J.T.; Morrissette, R.R.; Leach, B.N.

    1989-01-01

    This paper reports on a computer code called BETA that has been developed by health physicists at the Vermont Yankee Nuclear Power Station which accounts for the mass and size of hot particles of Cobalt-60, and therefore corrects the Loevinger-based dose calculation for self-absorption

  17. Effect of cobalt-60 radiation on response to endodontic therapy in monkeys

    International Nuclear Information System (INIS)

    Matson, J.E.; Patterson, S.S.; Kafrawy, A.H.; Hornback, N.B.; Shidnia, H.

    1978-01-01

    Response of teeth that had received therapeutic doses of Cobalt-60 radiation to endodontic therapy were investigated in three monkeys. The results indicated no appreciable effect of the irradiation on the response to root canal treatment aside from reduction in osteoblastic activity

  18. An economic benefit analysis on the cobalt-60 irradiation facility of Beijing Radiation Research Center

    International Nuclear Information System (INIS)

    Wang Binlin

    1995-01-01

    The peculiarity, the investment and annual operating cost of the 3.7 x 10 16 Bq (MCi) cobalt-60 irradiation facility at Beijing Radiation Application Research Centre are described. Its economic benefits each year are analyzed according to several year operating practice. Some related questions on carrying out radiation processing are raised and discussed. (author)

  19. Cobalt-60 gamma radiation effects on degradation of pesticides used in stored rice and beans

    International Nuclear Information System (INIS)

    Groppo, Gerson A.

    1988-02-01

    The present work, carried out at CENA, an agriculture nuclear energy center - University of Sao Paulo - Brazil, investigates the Cobalt-60 gamma radiation effects on insecticides applied to stored rice and beans. The radiation dose applied - 200 Gy - to the stored rice and beans treated with insecticides was not sufficient to cause a noticeable chemical degradation through insect mortality. (author). 31 refs., 23 tabs

  20. Radiation incidents with a cobalt-60 teletherapy unit

    Energy Technology Data Exchange (ETDEWEB)

    Lane, R G; Tolbert, D D; Pailwal, B R; Radtke, R R [Wisconsin Univ., Madison (USA). Dept. of Radiology

    1976-08-01

    Three radiation incidents associated with source drive failures on one particular /sup 60/Co teletherapy unit, which took place during a single year's operation, are discussed. In each case the extra treatment time of the patient, the exposure to the technician, the cause of the breakdown and the subsequent action taken are detailed. Recommendations for users of /sup 60/Co teletherapy units to minimise the results of the malfunctioning of such a system are given.

  1. Radiation incidents with a cobalt-60 teletherapy unit

    International Nuclear Information System (INIS)

    Lane, R.G.; Tolbert, D.D.; Pailwal, B.R.; Radtke, R.R.

    1976-01-01

    Three radiation incidents associated with source drive failures on one particular 60 Co teletherapy unit, which took place during a single year's operation, are discussed. In each case the extra treatment time of the patient, the exposure to the technician, the cause of the breakdown and the subsequent action taken are detailed. Recommendations for users of 60 Co teletherapy units to minimise the results of the malfunctioning of such a system are given. (U.K.)

  2. Cobalt-60 Machines and Medical Linear Accelerators: Competing Technologies for External Beam Radiotherapy.

    Science.gov (United States)

    Healy, B J; van der Merwe, D; Christaki, K E; Meghzifene, A

    2017-02-01

    Medical linear accelerators (linacs) and cobalt-60 machines are both mature technologies for external beam radiotherapy. A comparison is made between these two technologies in terms of infrastructure and maintenance, dosimetry, shielding requirements, staffing, costs, security, patient throughput and clinical use. Infrastructure and maintenance are more demanding for linacs due to the complex electric componentry. In dosimetry, a higher beam energy, modulated dose rate and smaller focal spot size mean that it is easier to create an optimised treatment with a linac for conformal dose coverage of the tumour while sparing healthy organs at risk. In shielding, the requirements for a concrete bunker are similar for cobalt-60 machines and linacs but extra shielding and protection from neutrons are required for linacs. Staffing levels can be higher for linacs and more staff training is required for linacs. Life cycle costs are higher for linacs, especially multi-energy linacs. Security is more complex for cobalt-60 machines because of the high activity radioactive source. Patient throughput can be affected by source decay for cobalt-60 machines but poor maintenance and breakdowns can severely affect patient throughput for linacs. In clinical use, more complex treatment techniques are easier to achieve with linacs, and the availability of electron beams on high-energy linacs can be useful for certain treatments. In summary, there is no simple answer to the question of the choice of either cobalt-60 machines or linacs for radiotherapy in low- and middle-income countries. In fact a radiotherapy department with a combination of technologies, including orthovoltage X-ray units, may be an option. Local needs, conditions and resources will have to be factored into any decision on technology taking into account the characteristics of both forms of teletherapy, with the primary goal being the sustainability of the radiotherapy service over the useful lifetime of the equipment

  3. Determination of cobalt-60 in seawater by solvent extraction with pyrrolidinedithiocarbamic acid

    International Nuclear Information System (INIS)

    Tseng, C.L.; Lo, J.M.

    1978-01-01

    Cobalt-60 was extracted from a large volume of seawater and concentrated in a small volume of organic solution of pyrrolidinedithiocarbamic acid (HPDC) in chloroform. All foreign nuclides in the organic phase were stripped completely with 12N HCl and 2N HNO 3 successively. By this procedure, a chemically pure Co-60 chelate, 60 Co(PDC) 3 , in chloroform was obtained. The recovery of Co-60 activity was found to average 99%. Cobalt-60 in seawater can thus be simply, rapidly and accurately determined by direct NaI(Tl) scintillation counting. The time for a single analysis, for example, exclusive of the counting operation, is about 40 min. The effects of various foreign nuclides on the extraction of Co-60 were examined by the use of 42 radiotracers and the results are tabulated. The nuclides Ag + , Mn 2+ , Ni 2+ , Cu 2+ , Zn 2+ , Cd 2+ , Pb 2+ , Hg 2+ , Fe 3+ , Ga 3+ , In 3+ , As 3+ , Sn 4+ , and Cr 6+ were extracted almost completely into chloroform with cobalt as the pyrrolidinedithiocarbamates. The extraction yield of Sb 3+ was close to 90%. Appreciable fractions of Cs + , Ba 2+ , Cr 3+ , Zr 4+ and Np 5+ were also found in the organic phase. (T.I.)

  4. REVISS cobalt-60 production in Russia and beyond

    Science.gov (United States)

    Coppell, David; Latham, Ian; Nazarov, Michael

    2004-09-01

    Since Russian English Venture in Isotope Supply and Services (REVISS) Services is one of only two major global suppliers of sealed radiation sources to the industrial sterilization industry, security of supply of raw materials is understandably of primary concern to the users in the market place. This paper outlines the history, facilities and production capability of REVISS isotope suppliers, from MAYAK Production Association and Leningrad Nuclear Power Plant in Russia to Commission Nacional Energia Atomica in Argentina. The paper provides technical details of reactors and handling facilities used for fabrication of 60Co and 137Cs sources for industrial and research gamma irradiators and other applications. Other sources of 60Co in the world today will be reviewed briefly.

  5. R I 800. A new cobalt-60 sealed source design

    International Nuclear Information System (INIS)

    Freijo, Jose L.; Gomez, Gonzalo

    2006-01-01

    The consolidation of the international market of Co-60 sources and the perspective of its growth has encouraged the development of new types of sealed sources. The model R I 800 is designed for activities up to 65 kCi and allows a large spectrum of capsules with different specific activities. During three years Dioxitek developed the process of fabrication and qualifications to comply the design requirements and succeeded in the product approval. Today, the initial lot at an industrial scale of R I 800 sources is under fabrication and a first partial shipment of 100 kCi to the United Kingdom was successfully carried out at the end of October 2005. The whole lot is for export. Due to the versatility of the R I 800 sealed sources it was possible to use as raw material 1 MCi of Co-60 imported from Russia, irradiated in Leningrad nuclear power plant. (author) [es

  6. Seed germination of peanuts irradiated with cobalt (60CO)

    International Nuclear Information System (INIS)

    Alves, Niedja Marrize C.; Almeida, Francisco de Assis C.; Gomes, Josivanda P.; Pessoa, Elvira B.; Leal, Artur S. Cavalcanti

    2010-01-01

    This work was realized to evaluate the effect of gamma irradiation ( 60 Co) at doses 0, 0.50, 1.00, 1.50, 2.00, 2.50, 3.00 and 4.00 kGy, on germination of seeds of peanut, cultivar BR1. Irradiation Department of Nuclear, UFPE, where he received after the irradiation, they were stored in packing of PET and polyethylene braided with a time of 90 days. Through the results, obtained monthly, concluded that the dose of 0.5 kGy was effective in the germination of seeds of peanut, not affecting its power of germination and overcoming the witness within 30 to 60 days. (author)

  7. SU-F-T-530: Characterization of a 60-Leaf Motorized MLC Designed for Cobalt-60 Units

    International Nuclear Information System (INIS)

    Xu, L; Smith, L; Ciresianu, A

    2016-01-01

    Purpose: In a continuing effort to improve conformal radiation therapy with Cobalt-60 units, a 60-leaf MLC was designed, manufactured, and released to market. This work describes the physics measurements taken to characterize the clinical performance of this MLC. Methods: A 60 leaf MLC was custom designed with tungsten leaves of 4.5 cm height, single focused, achieving field size of 30×30 cm^2 when mounted on a 100cm SAD Cobalt-60 unit. Leakage and output factor measurements were performed using a single ion chamber in a solid water phantom. Penumbra and surface dose were measured using scanning chambers and diodes in a water phantom. Radiation-light coincidence measurements were performed using radiographic films. Results: With MLC mounted, measured penumbras at all depths are smaller than with jaws only. Surface doses were not significantly affected by the presence of MLC, and remained below values recommended by regulatory bodies. Light-radiation coincidences were found to be better than 3 mm for all field sizes. Leakage through the MLC was found to be strongly dependent on field size, increasing from 1.0 % for a 10×10 cm field to 2.0% for a 30×30 cm field. Such results meet the requirements of IEC 60601-2-11. The MLC was found to have significant influence on the output factor, when field size defined by MLC is significantly smaller than field size defined by jaws. Such effect is also observed on linear accelerators, but it is more pronounced on Cobalt-60 units. A 10×10 “diamond” MLC shape inside a 14×14 cm jaw showed output factor that is 5.7% higher than 10×10 cm field defined by matching MLC and jaws. Conclusion: The MLC offers clinically acceptable performance in penumbra, surface dose, and light-radiation coincidence. Several units of this MLC have recently been installed and used clinically. Validation of Cobalt-60 based IMRT with this MLC is ongoing. The authors are employees of Best Theratrnics Ltd.

  8. SU-F-T-530: Characterization of a 60-Leaf Motorized MLC Designed for Cobalt-60 Units

    Energy Technology Data Exchange (ETDEWEB)

    Xu, L; Smith, L; Ciresianu, A [Best Theratronics, Ottawa, ON (Canada)

    2016-06-15

    Purpose: In a continuing effort to improve conformal radiation therapy with Cobalt-60 units, a 60-leaf MLC was designed, manufactured, and released to market. This work describes the physics measurements taken to characterize the clinical performance of this MLC. Methods: A 60 leaf MLC was custom designed with tungsten leaves of 4.5 cm height, single focused, achieving field size of 30×30 cm^2 when mounted on a 100cm SAD Cobalt-60 unit. Leakage and output factor measurements were performed using a single ion chamber in a solid water phantom. Penumbra and surface dose were measured using scanning chambers and diodes in a water phantom. Radiation-light coincidence measurements were performed using radiographic films. Results: With MLC mounted, measured penumbras at all depths are smaller than with jaws only. Surface doses were not significantly affected by the presence of MLC, and remained below values recommended by regulatory bodies. Light-radiation coincidences were found to be better than 3 mm for all field sizes. Leakage through the MLC was found to be strongly dependent on field size, increasing from 1.0 % for a 10×10 cm field to 2.0% for a 30×30 cm field. Such results meet the requirements of IEC 60601-2-11. The MLC was found to have significant influence on the output factor, when field size defined by MLC is significantly smaller than field size defined by jaws. Such effect is also observed on linear accelerators, but it is more pronounced on Cobalt-60 units. A 10×10 “diamond” MLC shape inside a 14×14 cm jaw showed output factor that is 5.7% higher than 10×10 cm field defined by matching MLC and jaws. Conclusion: The MLC offers clinically acceptable performance in penumbra, surface dose, and light-radiation coincidence. Several units of this MLC have recently been installed and used clinically. Validation of Cobalt-60 based IMRT with this MLC is ongoing. The authors are employees of Best Theratrnics Ltd.

  9. Radiological shielding of cobalt-60 teletherapy facility at Komfo Anokye Teaching Hospital, Kumasi, Ghana

    International Nuclear Information System (INIS)

    Addison, E.K.T.; Kitcher, H.W.; Kyere, A.W.K.; Nani, E.K.

    2003-01-01

    The radiological shielding of the radiotherapy unit, oncology directorate, Komfo Anokye teaching hospital, has been assessed based on the workload and occupancy factors, in addition to the technical and performance specification of the cirus cobalt-60 equipment. Aspects relating to the design of treatment room were described. Calculations were based on NCRP report 49 and measurements were carried out on the structural shielding design of the cobalt-60 unit by the standard method prescribed in the NCRP report 49. This study was carried out to evaluate the adequacy of the shielding put in place to ensure the safety of the staff, public and oncological patients. The results obtained and measurements made, all fall below the regulatory effective dose limit of 20 mSv per year for staff and 1 mSv per year for the public (author)

  10. Dosimetry of normal and wedge fields for a cobalt-60 teletherapy unit

    International Nuclear Information System (INIS)

    Tripathi, U.B.; Kelkar, N.Y.

    1980-01-01

    A simple analytical method for computation of dose distributions for normal and wedge fields is described and the use of the method in planning radiation treatment is outlined. Formulas has been given to compute: (1) depth dose along central axis of cobalt-60 beam, (2) dose to off-axis points, and (3) dose distribution for a wedge field. Good agreement has been found between theoretical and experimental values. With the help of these formulae, the dose at any point can be easily and accurately calculated and radiotherapy can be planned for tumours of very odd shape and sizes. The limitation of the method is that the formulae have been derived for 50% field definition. For cobalt-60 machine having any other field definition, appropriate correction factors have to be applied. (M.G.B.)

  11. Conceptual design of a conveyor system for the Philippine multipurpose cobalt-60 gamma irradiation facility

    International Nuclear Information System (INIS)

    Borras, A.M.

    1992-01-01

    The Multipurpose Cobalt-60 Gamma Irradiation Facility at the PNRI presently utilizes the batch irradiation method using turntables to rotate the product boxes. The target materials or products are being carried manually or with the use of pushcart through the personnel maze. This paper presents a conceptual design for the best suitable product-handling or conveyor system for the Philippine Multipurpose Cobalt-60 Gamma Irradiation Facility. The main irradiation conveyor line shall be a 55 cm x 200 cm slat-type conveyor made of SUS 304 material that could be operated in a semi-batch continuous flow and/or shuffle-dwell method with a tact-time range of 10 min to 7 h. The products can be irradiated in a single direction, two-pass, two-sided method. (auth.). 11 refs.; 4 figs.; 2 tabs

  12. Cobalt-60 simulation of LOCA [loss of coolant accident] radiation effects

    International Nuclear Information System (INIS)

    Buckalew, W.H.

    1989-07-01

    The consequences of simulating nuclear reactor loss of coolant accident (LOCA) radiation effects with Cobalt-60 gamma ray irradiators have been investigated. Based on radiation induced damage in polymer base materials, it was demonstrated that electron/photon induced radiation damage could be related on the basis of average absorbed radiation dose. This result was used to estimate the relative effectiveness of the mixed beta/gamma LOCA and Cobalt-60 radiation environments to damage both bare and jacketed polymer base electrical insulation materials. From the results obtained, it is concluded that present simulation techniques are a conservative method for simulating LOCA radiation effects and that the practices have probably substantially overstressed both bare and jacketed materials during qualification testing. 9 refs., 8 figs., 5 tabs

  13. Contamination of steel produced in the Czech Republic by cobalt 60

    International Nuclear Information System (INIS)

    Malatova, I.; Foltanova, S.; Rulik, P.

    1999-01-01

    In recent years, the metal recycling industry has become aware of the presence of radioactive materials in scrap metal. While the problem has historical roots dating to the earliest days of the use of radium, the use of radioactive materials in industrial devices, coupled with incorrect disposal of those devices led to many cases where radioactive sources were unintentionally smelted in the course of recycling. A survey was made of the steel contamination produced during file years 1993 to 1996 in nine steel producing plants. Altogether 721 steel samples were measured by semiconductor gamma spectrometry. In 62% of the samples, no cobalt 60 activity was detected, i.e. the activity was below the minimum significant activity. In 95.5% of the samples, activity concentration of cobalt 60 was below 10 Bq/kg and in 3.4% of the samples, the activity concentration was between 100 and 1000 Bq/kg. The samples were collected according to a scheme which ensured a random choice. In addition, eight samples collected in plants where file investigation was performed were measured, following the melting of contaminated scrap. These samples had activity concentration of cobalt 60 greater than 1000 Bq/kg. (author)

  14. A Vision Controlled Robot to Detect and Collect Fallen Hot Cobalt60 Capsules inside Wet Storage Pool of Cobalt60 Irradiators

    International Nuclear Information System (INIS)

    Solyman, A.E.M.

    2015-01-01

    In a typical irradiator that use radioactive cobalt-60 capsules source is one of the peaceful uses of atomic energy, it originated strategy in terms of its importance in the sterilization of medical products and food processing from bacteria and fungi before being exported. However, there are several well-known problems related to the fall of the cobalt-60 capsules inside the wet storage pool as a result of manufacturing defects, defects welds or a problem occurs in the vertical movement of the radioactive source rack. Therefore it is necessary to study this problem and solve it in a scientific way so as to keep the human as much as possible from radiation exposure, according to the principles of radiation protection and safety issued by the International Atomic Energy Agency. The present work considers the possibility to use a vision based control arm robot to collect fallen hot cobalt-60 capsules inside wet storage pool. A 5-DOF arm robot is designed and vision algorithms are established to pick the fallen capsule on the bottom surface of the storage pool, read the information printed on its edge (cap) and move it to a safe storage place. Two object detection approaches are studied; RGB-based filter and background subtraction technique. Vision algorithms and camera calibration are done using MATLAB/SIMULINK program. Robot arm forward and inverse kinematics are developed and programmed using an embedded micro controller system. Experiments show the validity of the proposed system and prove its success. The collecting process will be done without interference of operators, so radiation safety will be increased. The results showed camera calibration equations accuracy. And also the presence of vibrations in the hands of the movement of the robot and thus were seized motor rotation speed to 10 degrees per second to avoid these vibrations.This scientific application keeps the operators as much as possible from radiation exposure so it leads to increase radiation

  15. Field and laboratory evaluation of the mobility of cobalt-60/EDTA in an arid environment

    International Nuclear Information System (INIS)

    Jones, T.L.; Gee, G.W.; Swanson, J.L.; Kirkham, R.R.

    1983-02-01

    The ability of the organic complexant EDTA to enhance the mobility of cobalt-60 was investigated in both laboratory and field experiments. Laboratory tests consisted of short term (approximately 7 day) column and batch adsorption tests using soil from the Hanford site as well as long term (approximately 70 day) batch tests with Hanford soil and soils from Oak Ridge and Savannah River. In addition, two large scale tracer tests were conducted using Hanford soil. One used a large (1.6 m) laboratory column, spiked with cobalt-60/EDTA and the other was a field test conducted in an 8 m deep lysimeter. Enhanced mobility decreased sorption were observed in both column and batch tests when the cobalt-60/EDTA solutions contacted Hanford and Oak Ridge soil for only a few days. When long contact times were allowed (months) the Hanford soil showed large increases in sorption with time. The low sorption exhibited initially by the Oak Ridge soil increased slightly over time, however, the high sorption observed with the Savannah River soil remained constant with time. The reduced mobility, with time, observed in Hanford soils was confirmed in both the large scale laboratory and breaking down when contacted with Hanford and Savannah River soil and to a lesser extent, the Oak Ridge soil. It is not known at this time why the complex is breaking down or why the kinetics are different among the soils tested. The implication to waste management is that the potential for transport of cobalt by EDTA complexation may not be as serious as once thought

  16. High accumulation of cobalt-60 by the particular organ or part of some species in mollusca

    International Nuclear Information System (INIS)

    Yoshida, Katsuhiko

    1981-01-01

    A large amounts of samples in marine Cephalopoda and Tridacna were sampled in north west pacific ocean, near Japan. The samples were separated into organs or parts for determination of Co-60 concentration. A peculiar accumulation of Co-60 by the branchial heart of Octopus was also recognized in field condition, but it had become apparent that branchial heart of squid had not same ability. Liver of Cephalopoda had the ability to highly accumulate the Co-60 and specific activity of squid was one order highter than Octopus. The concentration of Cobalt-60 in visceral muss kidney of Tridacna maxima lineally increased with increasing shell length but that in other soft parts was kept constant. After examination of the other papers it was assumed that Co-60 highly accumulated in these organs was transfered by the food chain. (author)

  17. sup(60)Co hot atom chemistry of tris(acetylacetonato) cobalt(III) adsorbed on silica gel

    International Nuclear Information System (INIS)

    Nishioji, H.; Sakai, Y.; Tominaga, T.

    1985-01-01

    The sup(60)Co hot atom reactions were studied in tris(acetylacetonato)cobalt(III) adsorbed on silica gel surface. sup(57)Fe Moessbauer spectra of tris(acetylacetonato)iron(III) in the corresponding system were also measured in order to examine the state of dispersion of complex molecules on silica gel. The retention formation processes were discussed in terms of the dependence of sup(60)Co retention on the adsorbed amount (concentration) of cobalt(III) complexes. (author)

  18. Direct uptake of cobalt 60 by the carp (Cyprinus carpio L.) following experimental chronic or cyclical contamination of water

    International Nuclear Information System (INIS)

    Amiard-Triquet, C.; Foulquier, L.

    1978-01-01

    Irrespective of the nature of experimental cobalt 60 contamination (chronic or cyclical), the activity level in the carp was highest after 32 or 35 days when the concentration factor reached 3. An analysis of cobalt 60 distribution shows preferential uptake by the kidneys. It therefore seems unlikely that the discharge rate of effluents from the nuclear industry and the resulting variations of radioactivity levels in the water significantly modify the impact of contamination on aquatic organisms [fr

  19. Differential gene expression in primary fibroblasts induced by proton and cobalt-60 beam irradiation

    DEFF Research Database (Denmark)

    Nielsen, Steffen; Bassler, Niels; Grzanka, Leszek

    2017-01-01

    profile: entrance, mid-SOBP and at the SOBP distal edge. Dose was delivered in three fractions × 3.5 Gy(RBE) (RBE 1.1). Cobalt-60 (Co-60) irradiation was used as reference. Real-time qPCR was performed to determine gene expression levels for 17 genes associated with inflammation response, fibrosis...... and angiogenesis. RESULTS: Differences in median gene expression levels were observed for multiple genes such as IL6, IL8 and CXCL12. Median IL6 expression was 30%, 24% and 47% lower in entrance, mid-SOBP and SOBP distal edge groups than in Co-60 irradiated cells. No genes were found to be oppositely regulated...... fibroblast cultures. Inflammatory factors were generally less extensively upregulated by proton irradiation compared with Co-60 photon irradiation. These effects may possibly influence the development of normal tissue damage in patients treated with proton beam therapy....

  20. Transport of radioactive source of cobalt-60 for the steel industry

    International Nuclear Information System (INIS)

    Santos, Paulo de Oliveira

    2009-01-01

    Radioactive materials are used in the fields of medicine, industry, research and nuclear power production. The use of radioactive material may involve transportation and this implies in the application of safety measures to the workers, public and the environment. Many types of radioactive material are produced all over the world and some modes of transport are involved. The IAEA regulations are based on the philosophy that radioactive material being transported should be adequately packaged to provide protection against the hazards of the material under all conditions of transport. Some Brazilian steel industries control the levels of liquid steel in continuous casting systems by means of sealed sources of cobalt-60. The Center for Development of Nuclear Technology-CDNT produces several of these sources to meet these industries and these sources must be transported in packages designed and tested as requirements of the rules of carriage of radioactive materials. For the transportation of seven sources of cobalt-60 with total activity of 1 GBq since CDNT to the applicant industries was designed, built and tested a Type A package. The thickness of the shield to meet the surface dose rate and the index of transport was calculated by MCNP (Monte Carlo N-Particle Transport Code-Version 5) and practical values were compatible. The sealed sources of cobalt-60 were tested as to leak through the tightness test conducted according to ISO 9978:1992 (E) and the tests to demonstrate the capability of resistance of packaged under normal conditions of transport were made on the facilities of CDNT. (author)

  1. Analysis and development of methods of correcting for heterogeneities to cobalt-60: computing application

    International Nuclear Information System (INIS)

    Kappas, K.

    1982-11-01

    The purpose of this work is the analysis of the influence of inhomogeneities of the human body on the determination of the dose in Cobalt-60 radiation therapy. The first part is dedicated to the physical characteristics of inhomogeneities and to the conventional methods of correction. New methods of correction are proposed based on the analysis of the scatter. This analysis allows to take account, with a greater accuracy of their physical characteristics and of the corresponding modifications of the dose: ''the differential TAR method'' and ''the Beam Substraction Method''. The second part is dedicated to the computer implementation of the second method of correction for routine application in hospital [fr

  2. Chronic cardiac arrhythmias produced by focused cobalt-60 gamma irradiation of the canine atria

    International Nuclear Information System (INIS)

    Dick, H.L.H.; Saylor, C.B.; Reeves, M.M.; Davies, M.J.

    1979-01-01

    Cardiac arrhythmias following exposure of the human heart to ionizing radiation have been reported. Earlier experiments involving irradiation of the hearts of various animals failed to consistently produce similar arrhythmias. In the present work, cobalt-60 irradiation was focused on the interatrial septum of the hearts of 12 dogs. Ten animals developed arrhythmias: These were repetive junctional and atrial tachycardias, repetitive atrial fibrillation, and type one, second-degree atrial ventricular block. The duration varied from 1 to 52 days, with onsets varying from 48 to 146 days postirradiation

  3. Preliminary dosimetric methodology for a new cobalt-60 irradiator for radioinduced necrosis

    International Nuclear Information System (INIS)

    Moura, Eduardo S.; Mosca, Rodrigo C.; Zeituni, Carlos A.; Rostelato, Maria Elisa C.M.; Mathor, Monica B.; Sakuraba, Roberto K.; Goncalves, Vinicius D.

    2011-01-01

    The use of ionizing radiation in medical procedures, as radiotherapy, is a well-established clinical process and it has been used for several decades with good clinical results and continuous technology development for treatment optimization. On the contrary, some injuries such as necrosis, may occur with patients, due to wrong administration of the absorbed dose or with expected side effects. To evaluate how these injuries could be investigated and how they can be treated, a new Cobalto-60 irradiator was developed to induce radionecrosis in mice. This irradiator is composed by a cylindrical size and it was set up with eleven Cobalt-60 sources aligned in the surface of a cylindrical lead. This alignment guarantees a small dose focal area in a longitudinal table, with proper frames for positioning mice precisely during the irradiations period. The dosimetric procedure will measure the absorbed dose in the dose focal area, delimited the area of irradiation with penumbra regions (gradients absorbed dose profiles) and others anatomical regions of the mice with high radiosensitivity. Possible dosimetric procedures and related devices will be present in this work,. The obtained dosimetric data will be applied to ensure the accurate period of radiation of a given position. This preliminary study assures that the fundamental dosimetric process of this new Cobalt-60 irradiator and it predicates that dosimetric processes area feasible to be conducted. (author)

  4. Preliminary dosimetric methodology for a new cobalt-60 irradiator for radioinduced necrosis

    Energy Technology Data Exchange (ETDEWEB)

    Moura, Eduardo S.; Mosca, Rodrigo C.; Zeituni, Carlos A.; Rostelato, Maria Elisa C.M.; Mathor, Monica B., E-mail: esmoura@ipen.b [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil); Sakuraba, Roberto K.; Goncalves, Vinicius D. [Hospital Israelita Albert Einstein (HIAE), Sao Paulo, SP (Brazil)

    2011-07-01

    The use of ionizing radiation in medical procedures, as radiotherapy, is a well-established clinical process and it has been used for several decades with good clinical results and continuous technology development for treatment optimization. On the contrary, some injuries such as necrosis, may occur with patients, due to wrong administration of the absorbed dose or with expected side effects. To evaluate how these injuries could be investigated and how they can be treated, a new Cobalto-60 irradiator was developed to induce radionecrosis in mice. This irradiator is composed by a cylindrical size and it was set up with eleven Cobalt-60 sources aligned in the surface of a cylindrical lead. This alignment guarantees a small dose focal area in a longitudinal table, with proper frames for positioning mice precisely during the irradiations period. The dosimetric procedure will measure the absorbed dose in the dose focal area, delimited the area of irradiation with penumbra regions (gradients absorbed dose profiles) and others anatomical regions of the mice with high radiosensitivity. Possible dosimetric procedures and related devices will be present in this work,. The obtained dosimetric data will be applied to ensure the accurate period of radiation of a given position. This preliminary study assures that the fundamental dosimetric process of this new Cobalt-60 irradiator and it predicates that dosimetric processes area feasible to be conducted. (author)

  5. Transport of Cobalt 60 from the Argentine Nuclear Power Plant in Embalse

    International Nuclear Information System (INIS)

    Lopez Vietri, J.R.

    2011-01-01

    Full text: The purpose of this presentation is to point out some relevant issues related to the transport of cobalt 60 for domestic uses and export from the Argentine Nuclear Power Plant located in Embalse (ENPP). It is remarked that in last 22 years, ENPP produced about 2600 PBq (70 MCi) of Co-60, and that Argentina is the third Co-60 producer, after Canada and Russia. It is mentioned that in Argentina there are facilities which manufacture Zircaloy seamless tubes and reactivity control bars containing cobalt 59 to be used in ENPP, the operation of Candu reactor at ENPP including cobalt-related activities, and the manufacture and commercialization of Co-60 sealed sources. The Argentine Nuclear Regulatory Authority verifies the compliance of nuclear activities with regulatory standards, including those related to the transport of radioactive material. Then, it is described the process for obtaining Co-60 at ENPP with an activity concentration to allow its use in medicine and industry. After that, is considered in detail the type of package used for the transport of Co-60 from ENPP: it is to say, Type B(U) package designs that must be approved by the Competent Authority origin of the design, and they are able to withstand routine, normal and accident conditions of transport, including severe impacts, fires and immersion in water. The overall dimensions of packages are about 1.0 m to 1.5 m diameter by 1.2 m to 1.8 m high, as well as the gross mass could vary from 6500 kg to 9500 kg. Radioactive contents consist of Co-60 sealed sources (called pencils), with an activity range from 8 PBq to 16 PBq. Then, it is considered activities prior to dispatch of Type B(U) packages at ENPP, including the preparation of radioactive contents, packaging and package (labelling and marking) as well as necessary tests and documentation for transport in order to fulfil pertinent requirements of package design operation manual of the package and related standards. Finally, it is pointed

  6. Experimental investigation of cobalt-60 accumulation and elimination in Cyprinus carpio (L.)

    International Nuclear Information System (INIS)

    Fritsch, A.F.

    1985-11-01

    When introduced in cation form, 60 Co showed a distinct tendency to form anion or neutral complexes (50% and 20%, respectively); this was favorized by a high biomass content per liter of water. The ionic evolution of the radionuclide did not affect its accumulation level in the fish. Direct contamination predominated (70%) and the concentration factor at equilibrium was 10. Nutritional transfer from Limnaea to carp, after ingestion of 45 contaminated rations in 63 days, resulted in a low radionuclide retention factor (3 x 10 -3 ) that was not subject to bioamplification. Cobalt-60 was primarily eliminated via urine (60%), while the fecal matter contained only 20% of the radioactive isotope ingested in the food. The 60 Co content of carp contaminated from the water increased proportionally with the temperature. However, the 60 Co concentration did not vary significantly with the thermal factor, and the radionuclide concentration factor ranged from 4 to 6 between 8 0 C and 25 0 C. Decontamination was generally a two-phase process characterized by a short biological half-life ( 60 Co contained in the fish. The high 60 Co content of the digestive tract may be explained by fecal excretion of the radioactive isotope (30-40% of the elimination). The kidneys act as radionuclide elimination regulators via the urinary system [fr

  7. Effect of cobalt-60 irradiation on the developing tooth germ of rat

    Energy Technology Data Exchange (ETDEWEB)

    You, Dong Soo; Lee, Ki Sik [Department of Dental Radiology, Graduate School, Seoul National University, Seoul (Korea, Republic of)

    1976-11-15

    The author observed the effects of the cobalt-60 irradiation on the amelogenesis and dentinogenesis of the albino rat fetuses by means of histological and histochemical methods. Female in oestrus were mated overnight and examined the next morning for evidence of copulation. The lower left abdomen of mothers were exposed to cobalt-60 irradiation on the 10th day of gestation, 100R 200R and 300R respectively. The fetuses were removed from the mothers on the 18th day of gestation. The employed histochemical methods were PAS reaction, colloidal iron reaction, aldehyde fuchsin stain, -amino acid reaction, -SH radical reaction, and methyl green pyronin stain. The results were as follows; 1. The group irradiated by 100R made no histological differences in comparison with the control group. 2. Increasing the irradiation to 200R, abnormal dentin formation occurred, and resulted in enamel hypoplasia, atrophy, and necrosis of odontoblasts. In dentinal papilla, the dilation and the degeneration of the blood vessels, excessive reticular atrophy, and osteodentin were revealed. 3. With the more irradiation (200R-300R), the positive material of PAS, {alpha}-amino acid and aldehyde fuchsin tended to decrease in the ameloblast and in the odontoblast. No significant changes appeared in DNA, the stainability of methylgreen pyronin.

  8. Computer generation of cobalt-60 single beam dose distribution using an analytical beam model

    International Nuclear Information System (INIS)

    Jayaraman, S.

    1981-01-01

    A beam dose calculation model based on evaluation of tissue air ratios (TAR) and scatter air ratios (SAR) for cobalt-60 beams of rectangular cross section has been developed. Off-central axis fall-off of primary radiation intensity is derived by an empirical formulation involving an arctangent function with the slope of the geometrical penumbra acting as an essential constant. Central axis TAR and SAR values are assessed by semi-empirical polynomial expressions employing the two sides of the rectangular field as the bariables. The model utilises a minimum number of parametric constants and is useful for computer generation of isodose curves. The model is capable of accounting for situations where wedge filters or split field shielding blocks, are encountered. Further it could be widely applied with minor modifications to several makes of the currently available cobalt-60 units. The paper explains the model and shows examples of the results obtained in comparison with the corresponding experimentally determined dose distributions. (orig.) [de

  9. Introduction dosimetric data of cobalt-60 unit in planning new Win-PTL- 3D

    International Nuclear Information System (INIS)

    Gonzalez Perez, Yelina; Rodriguez Zayas, Michael; Perez Guevara, Adrian; Sanchez Zamora, Luis; Reyes Gonzalez, Tommy; Sola Rodriguez, Yeline; Caballero, Roberto; Cruz Marcane, Viviana

    2009-01-01

    3D planning is based on the individual and image reconstruction formation of fields, allowing better absorption of dose volume White minimizing damage to surrounding healthy tissue. During the clinical implementation of the Win-PLT software includes validation from the implementation of dosimetric acceptance tests through a series of precise experimental measurements, reflecting different clinical situations (test cases). For the commissioning characterized the photon beam Cobalt Unit 60, taking measurements with a set consisting of a phantom dosimetric automatic ionization chambers and electrometer Tandem. The measured data are used to power the TPS through WINCOM auxiliary program that lets you adjust a number of parameters to model the photon beam. This adjustment is made by comparing the PDD curves and profiles of experimental data with modeled data. The test cases performed are in compliance with the requirements proposed in the geometric of the AAPM TG55. The modeling of beam dosimetry data was successful, since the discrepancies were within the criteria TRS-430. The cases involved events where points near the edge of the field and in the presence of blocking a discrepancy outside the tolerance, suggesting not to use these items for purposes of limitation. Win TPS-PLT is suitable for clinical use with the photon beam Cobalt Unit 60, backed by the reliability that dropped on the results of beam modeling and verification of dosimetric calculations. (Author)

  10. Evaluation of cobalt-60 energy deposit in mouse and monkey using Monte Carlo simulation

    Energy Technology Data Exchange (ETDEWEB)

    Woo, Sang Keun; Kim, Wook; Park, Yong Sung; Kang, Joo Hyun; Lee, Yong Jin [Korea Institute of Radiological and Medical Sciences, KIRAMS, Seoul (Korea, Republic of); Cho, Doo Wan; Lee, Hong Soo; Han, Su Cheol [Jeonbuk Department of Inhalation Research, Korea Institute of toxicology, KRICT, Jeongeup (Korea, Republic of)

    2016-12-15

    These absorbed dose can calculated using the Monte Carlo transport code MCNP (Monte Carlo N-particle transport code). Internal radiotherapy absorbed dose was calculated using conventional software, such as OLINDA/EXM or Monte Carlo simulation. However, the OLINDA/EXM does not calculate individual absorbed dose and non-standard organ, such as tumor. While the Monte Carlo simulation can calculated non-standard organ and specific absorbed dose using individual CT image. External radiotherapy, absorbed dose can calculated by specific absorbed energy in specific organs using Monte Carlo simulation. The specific absorbed energy in each organ was difference between species or even if the same species. Since they have difference organ sizes, position, and density of organs. The aim of this study was to individually evaluated cobalt-60 energy deposit in mouse and monkey using Monte Carlo simulation. We evaluation of cobalt-60 energy deposit in mouse and monkey using Monte Carlo simulation. The absorbed energy in each organ compared with mouse heart was 54.6 fold higher than monkey absorbed energy in heart. Likewise lung was 88.4, liver was 16.0, urinary bladder was 29.4 fold higher than monkey. It means that the distance of each organs and organ mass was effects of the absorbed energy. This result may help to can calculated absorbed dose and more accuracy plan for external radiation beam therapy and internal radiotherapy.

  11. Evaluation of cobalt-60 energy deposit in mouse and monkey using Monte Carlo simulation

    International Nuclear Information System (INIS)

    Woo, Sang Keun; Kim, Wook; Park, Yong Sung; Kang, Joo Hyun; Lee, Yong Jin; Cho, Doo Wan; Lee, Hong Soo; Han, Su Cheol

    2016-01-01

    These absorbed dose can calculated using the Monte Carlo transport code MCNP (Monte Carlo N-particle transport code). Internal radiotherapy absorbed dose was calculated using conventional software, such as OLINDA/EXM or Monte Carlo simulation. However, the OLINDA/EXM does not calculate individual absorbed dose and non-standard organ, such as tumor. While the Monte Carlo simulation can calculated non-standard organ and specific absorbed dose using individual CT image. External radiotherapy, absorbed dose can calculated by specific absorbed energy in specific organs using Monte Carlo simulation. The specific absorbed energy in each organ was difference between species or even if the same species. Since they have difference organ sizes, position, and density of organs. The aim of this study was to individually evaluated cobalt-60 energy deposit in mouse and monkey using Monte Carlo simulation. We evaluation of cobalt-60 energy deposit in mouse and monkey using Monte Carlo simulation. The absorbed energy in each organ compared with mouse heart was 54.6 fold higher than monkey absorbed energy in heart. Likewise lung was 88.4, liver was 16.0, urinary bladder was 29.4 fold higher than monkey. It means that the distance of each organs and organ mass was effects of the absorbed energy. This result may help to can calculated absorbed dose and more accuracy plan for external radiation beam therapy and internal radiotherapy.

  12. Effect of cobalt-60 irradiation on the developing tooth germ of rat

    International Nuclear Information System (INIS)

    You, Dong Soo; Lee, Ki Sik

    1976-01-01

    The author observed the effects of the cobalt-60 irradiation on the amelogenesis and dentinogenesis of the albino rat fetuses by means of histological and histochemical methods. Female in oestrus were mated overnight and examined the next morning for evidence of copulation. The lower left abdomen of mothers were exposed to cobalt-60 irradiation on the 10th day of gestation, 100R 200R and 300R respectively. The fetuses were removed from the mothers on the 18th day of gestation. The employed histochemical methods were PAS reaction, colloidal iron reaction, aldehyde fuchsin stain, -amino acid reaction, -SH radical reaction, and methyl green pyronin stain. The results were as follows; 1. The group irradiated by 100R made no histological differences in comparison with the control group. 2. Increasing the irradiation to 200R, abnormal dentin formation occurred, and resulted in enamel hypoplasia, atrophy, and necrosis of odontoblasts. In dentinal papilla, the dilation and the degeneration of the blood vessels, excessive reticular atrophy, and osteodentin were revealed. 3. With the more irradiation (200R-300R), the positive material of PAS, α-amino acid and aldehyde fuchsin tended to decrease in the ameloblast and in the odontoblast. No significant changes appeared in DNA, the stainability of methylgreen pyronin.

  13. Cobalt-60 oxide aerosols: methods of production and short-term retention and distribution kinetics in the beagle dog

    International Nuclear Information System (INIS)

    Barnes, J.E.; Kanapilly, G.M.; Newton, G.J.

    1976-01-01

    Cobalt-60 has been used extensively in nuclear applications and has been considered for use in nuclear auxiliary power devices. The most common chemical form used is the oxide. This study of the retention and distribution of two differnt exoides of cobalt when administered by inhalation was conducted to assess the potential inhalation hazard associated with its use. Cobaltosic oxide (Co 3 O 4 ) was formed by passing a cobalt nitrate aerosol through a heating column at 850 0 C before delivery to the dog. Cobaltous oxide (CoO) was formed by raising the heating column temperature to 1400 0 C. Three beagle dogs were exposed to 60 Co 3 O 4 and sacrificed singly at 8, 64 and 128 days. Three beagle dogs were exposed to 60 CoO and sacrificed at 8, 16 and 64 days after exposure. Whole-body retention patterns showed that 60 CoO left the body with a shorter effective half-life than 60 Co 3 O 4 . The concentration of 60 Co detected in the blood was at least an order of magnitude higher in the dogs exposed to 60 CoO than in the dogs exposed to 60 Co 3 O 4 . Cobalt-60 translocated from the lung accumulated predominantly in the kidney, liver, skeleton and cartilagenous structures such as the trachea. Higher concentrations were reached earlier in the dogs exposed to 60 CoO. After early fecal excretion of material deposited in the upper respiratory tract, excretion was greatest via the urine. The higher solubility of the 60 CoO formed at 1400 0 C relative to 60 Co 3 O 4 formed at 850 0 C is noteworthy considering that generally aerosols formed at higher temperatures are more insoluble than aerosols formed at lower temperatures. (author)

  14. Effect of cobalt on the growth of Trichoderma viride and determination of its distribution using 60Co

    International Nuclear Information System (INIS)

    Frank, V.; Lesny, J.; Babej, L.

    1993-01-01

    The growth and morphology of filamentous fungus Trichoderma viride grown in the presence of various Co concentrations were studied. Using 60 Co, the cobalt content in mycelium and conidia was determined. No influence of 60 Co-radiation on growth and morphology was observed. (author) 5 refs.; 4 figs

  15. Dosimetric intercomparison in Cobalt 60 unities using TLD-100 crystals and CaSO4: Dy + Ptfe

    International Nuclear Information System (INIS)

    Gaona, E.; Azorin N, J.; Perez P, M.A.; Castillo H, M.; Flores F, F.; Guzman R, L.V.

    1999-01-01

    The purpose of this work is to design and construct a phantom in basis of thermoplastic polymer of methyl methacrylate that is reutilizable and which allows to do an analysis of the absorbed doses in thermoluminescent crystals (Tl) exposed to cobalt 60 to establish the dosimetric intercomparison in cobalt units which allows to do the follow-up of the Quality assurance programs, standardization of calibration procedures, dosimetry and TLD post intercomparison in radiotherapy. This work allows also prove new thermoluminescent materials of national manufacture developed by Juan Azorin and collaborators as the CaSO 4 : Dy + Ptfe. This is a first study which is realized in Mexico with the system crystal-phantom for aims to intercomparison in cobalt 60 units. In this work participate eight unities of cobalt 60 of different trades belonging at four radiotherapy centers. The results of the dose intercomparison of the eight unities of cobalt 60 were in the range 0.95-1.13, taking in account that the values between 0.95 and 1.05 were considered acceptable in terms of the requirements by the standing legislation. (Author)

  16. The ''Cobalt 60 Case'' in Taiwan. Conclusions; Das Kobalt-60 Ereignis von Taiwan. Und was ist daraus zu schliessen?

    Energy Technology Data Exchange (ETDEWEB)

    Niemann, Lutz

    2017-08-15

    The ''Cobalt 60 Case'' in Taiwan gives an opportunity for check of the thesis of radiation hormesis. Apartment residents have been exposed to cobalt-60 contaminated steel buildings. The results of a study strongly suggest that whole-body chronic irradiation, in the dose rate range that the apartment residents received, caused no symptomatic adverse health effects, such as radiation sickness, or the increased cancer or increased congenital disease that are predicted by ICRP theories. On the contrary, those who were exposed had lower incidences of cancer mortality and congenital malformations.

  17. Semi-empirical equivalent field method for dose determination in midline block fields for cobalt - 60 beam

    International Nuclear Information System (INIS)

    Tagoe, S.N.A.; Nani, E.K.; Yarney, J.; Edusa, C.; Quayson-Sackey, K.; Nyamadi, K.M.; Sasu, E.

    2012-01-01

    For teletherapy treatment time calculations, midline block fields are resolved into two fields, but neglecting scattering from other fields, the effective equivalent square field size of the midline block is assumed to the resultant field. Such approach is underestimation, and may be detrimental in achieving the recommended uncertainty of ± 5 % for patient's radiation dose delivery. By comparison, the deviations of effective equivalent square field sizes by calculations and experiments were within 13.2 % for cobalt 60 beams of GWGP80 cobalt 60 teletherapy. Therefore, a modified method incorporating the scatter contributions was adopted to estimate the effective equivalent square field size for midline block field. The measured outputs of radiation beams with the block were compared with outputs of square fields without the blocks (only the block tray) at depths of 5 and 10 cm for the teletherapy machine employing isocentric technique, and the accuracy was within ± 3 % for the cobalt 60 beams. (au)

  18. Research and design of the moving system for the cobalt-60 industrial irradiator

    International Nuclear Information System (INIS)

    Le Minh Tuan; Tran Khac An; Cao Van Chung; Phan Phuoc Thang

    2016-01-01

    On the way of localization of Cobalt-60 industrial irradiators, Research and Development Center for Radiation Technology (VINAGAMMA) has successfully designed and manufactured the first version of Co-60 industrial irradiator, VINAGA1. The second version of Co-60 industrial irradiator has been studied and designed by VINAGAMMA in the frame of the scientific project No. DTCB.02/15/TTNCTK. The nucleus of a Co-60 industrial irradiator is a mechanical system inside an irradiation room namely a tote box moving system. This report presents the tote box moving system designed by VINAGAMMA. The tote box moving system contains 52 tote boxes with the dimensions of 50 cm (w) × 70 cm (l) × 150 cm (h) that are moving around the source racks in the manner of 4 passes and 2 levels. The irradiator with this tote box moving system has good specifications: The minimum time of an irradiation cycle is 1h 20 min and the dose uniformity ratio (DUR) at the product densities of 0.1 g/cm 3 and 0.5 g/cm 3 is 1.4 and 1.8, respectively. Radiation energy utilization efficiency at the product densities of 0.1 g/cm 3 and 0.5 g/cm 3 is 19.7% and 48.8%, respectively. These specifications meet the requirements for a multi-purpose Co-60 industrial irradiator and the present irradiation requirements in Vietnam. (author)

  19. Research and design of the moving system for the cobalt-60 industrial irradiator VINAGA2

    International Nuclear Information System (INIS)

    Le Minh Tuan; Tran Khac An; Nguyen Ngoc Phuong; Tran Van Hung; Cao Van Chung; Phan Phuoc Thang; Ha Thanh Viet; Nguyen Thanh Cuong; Nguyen Duc Hoa

    2017-01-01

    On the way of localization of Cobalt-60 industrial irradiators, Research and Development Center for Radiation Technology (VINAGAMMA) has successfully designed and manufactured the first version of Co-60 industrial irradiator, VINAGA1. The second version of Co-60 industrial irradiator has been studied and designed by VINAGAMMA in the frame of the scientific project No. DTCB.02/15/TTNCTK. The main system of a Co-60 industrial irradiator is a mechanical system inside an irradiation room namely a tote box moving system. This report presents the tote box moving system of VINAGA2 designed by VINAGAMMA. The tote box moving system contains 52 tote boxes with the dimensions of 50 cm (w) × 70 cm (l) × 150 cm (h) that are moving around the source racks in the manner of 4 passes and 2 levels. The irradiator VINAGA2 with this tote box moving system has good specifications: The minimum time of an irradiation cycle is 1 h 20 min. and the dose uniformity ratio (DUR) at the product densities of 0.1 g/cm 3 and 0.5 g/cm 3 is 1.4 and 1.8, respectively. Radiation energy utilization efficiency at the product densities of 0.1 g/cm 3 and 0.5 g/cm 3 is 19.7% and 48.8%, respectively. These specifications meet the requirements for a multi-purpose Co-60 industrial irradiator and the present irradiation requirements in Vietnam. (author)

  20. Comparison of skin doses to large fields using tangential beams from cobalt-60 gamma rays and 4-MV x rays

    International Nuclear Information System (INIS)

    Gagnon, W.F.; Peterson, M.D.

    1978-01-01

    Excess radiation to the skin during external beam megavoltage radiation therapy has reportedly caused excessive erythema in patients treated with the Clinac 4 linear accelerator on sloping surfaces, but not for similar treatments with cobalt-60. Doses at the epidermal level were measured under geometries simulating sloping surfaces for a Clinac 4 and an Eldorado 8 cobalt-60 teletherapy machine. For equal doses to the axilla, doses to the epidermal layer were similar. When the tumor dose was calculated for the mediastinum, the dose to the skin in the axillary region was 12% higher for the Clinac 4

  1. Cobalt-60 and Caesium-137 Gamma Sources; Sources de rayonnement gamma au cobalt-60 et au cesium-137; Gamma-istochniki iz kobal'ta-605 i tseziya-137; Fuentes gamma de cobalto-60 y de cesio-137

    Energy Technology Data Exchange (ETDEWEB)

    Kulish, E E; Fradkin, G M [Academy of Sciences of the USSR, Moscow, Union of Soviet Socialits Republics (Russian Federation)

    1960-07-15

    The paper gives the main technical characteristics of gamma sources produced in the USSR using cobalt-60 and caesium-137 and discusses some of the problems of their production technology. The paper contains information on the radiation spectra of Co{sup 60} and Cs{sup 137} and of the source material from which they are prepared. Data are given on the dependence of the activity of cobalt sources upon the intensity of the neutron beam and the geometrical size of the sample. The yield of caesium by uranium fission is also analyzed. The problem of hermetic sealing of the sources is discussed and a complete nomenclature of all the sources manufactured in the USSR are listed, their size and activity also being indicated. In conclusion a comparison of Co{sup 60} and Cs{sup 137} sources is made. (author) [French] Cette communication expose les caracteristiques techniques fondamentales des sources de rayonnement gamma a base de cobalt-60 et de cesium-137 pro- duites en URSS; on y examine egalement certaines questions relatives a la technologie de leur production. La communication contient des donnees sur la nature du rayonnement des isotopes {sup 60}Co et {sup 137}Cs, ainsi que sur celle des matieres brutes utilisees pour leur preparation. On donne les resultats obtenus lors de l'etude de la variation de l'activite des sources au cobalt en fonction de la valeur du flux de neutrons et des dimensions geometriques de l'echantillon, ainsi que les resultats relatifs a la valeur du rendement en isotopes de cesium lors de la fission des noyaux d'uranium. On etudie ensuite les procedes pour assurer l'hermeticite de ces sources. Suit une nomenclature complete des sources produites en URSS, comportant des indications sur leurs dimensions geometriques et sur les valeurs de leur activite. Enfin, il est procede a une comparaison des sources au {sup 60}Co et au {sup 137}Cs. (author) [Spanish] En este informe se describen las principales caracteristicas tecnicas de las fuentes gamma de

  2. Immunological assessment of mice hyperimmunized with native and Cobalt-60-irradiated Bothrops venoms

    International Nuclear Information System (INIS)

    Ferreira Junior, R.S.; Meira, D.A.; Martinez, J.C.

    2005-01-01

    ELISA was used to evaluate, accompany, and compare the humoral immune response of Swiss mice during hyperimmunization with native and Cobalt-60-irradiated ( 60 Co) venoms of Bothrops jararaca, Bothrops jararacussu and Bothrops moojeni. Potency and neutralization were evaluated by in vitro challenges. After hyperimmunization, immunity was observed by in vivo challenge, and the side effects were assessed. The animals immunization with one LD50 of each venom occurred on days 1, 15, 21, 30, and 45, when blood samples were collected; challenges happened on the 60th day. Results showed that ELISA was efficient in evaluating, accompanying and comparing mouse immune response during hyperimmunization. Serum titers produced with natural venom were similar to those produced with irradiated venom. Immunogenic capacity was maintained after 60 Co-irradiation. The sera produced with native venom showed neutralizing potency and capacity similar to those of the sera produced with irradiated venom. All antibodies were able to neutralize five LD50 from these venoms. Clinical alterations were minimum during hyperimmunization with irradiated venom, however, necrosis and death occurred in animals inoculated with native venom. (author)

  3. Transfer of Cobalt-60 to plants from soils treated with sewage sludge

    International Nuclear Information System (INIS)

    Grummitt, W.E.

    1976-01-01

    The uptake of 60 Co from soils fertilized with contaminated sewage sludge has been investigated under a variety of experimental conditions. A number of garden plots were prepared by thoroughly mixing sludge containing 60 Co with farm soils from the Ottawa Valley. Edible plants were grown in the open on these plots under conditions approximating those in market gardens. The crops were harvested at maturity and were prepared for measurement of 60 Co by drying portions of the roots, leaves, stems and fruit. The samples were counted on a large germanium detector which was capable of resolving 60 Co from other gamma-emitting nuclides. Cobalt was readily taken up from contaminated sludge but was nonuniformly distributed in various parts of the plant. In general, the roots showed the highest levels while edible portions such as seeds and tubers had much lower concentrations. The uptake ratio, expressed as radioactivity in the sample to radioactivity in the soil, varied from 0.003 to 8 on a dry-weight basis. (author)

  4. Sensory analysis of dairy products irradiated with cobalt-60 at -78 degrees C

    International Nuclear Information System (INIS)

    Hashisaka, A.E.; Einstein, M.A.; Rasco, B.A.; Hungate, F.P.; Dong, F.M.

    1990-01-01

    Sensory evaluations by healthy individuals were conducted on cobalt-60 irradiated retail dairy products which were to be incorporated into the low microbial diets of immunosuppressed patients. Irradiation (40 kGy at -78 degrees C) caused little change in product color or texture, but generally there was a decrease in overall acceptability and an increase in off-flavor and aftertaste. Modified atmosphere packaging (nitrogen, helium, or air) or antioxidant addition (ascorbyl palmitate or a combination of butylated hydroxyanisole and butylated hydroxytoluene) prior to irradiation were effective in preserving specific sensory attributes, which in some cases resulted in improved overall acceptability (helium packed peppermint ice cream; ascorbyl palmitate treated strawberry yogurt bars) when compared to untreated irradiated products

  5. Effect of cobalt-60 gamma-ray irradiation on beans (Phaseolus vulgaris L.) of huasteco variety

    International Nuclear Information System (INIS)

    Navarro A, W.

    1984-01-01

    Bean seeds, Huasteco variety, were irradiated at 10, 20, 30 and 40 kR in a cobalt-60 gamma-ray source. Non-irradiated seeds were used as control. Irradiated and non-irradiated seeds were planted under greenhouse conditions using a random design and a population of 200 plants per treatment for both first and second generations (M 1 and M 2 ). The characters studied were; germination, survival, morphological changes of leaves and stem, change in seed coat colour, flowering, height, stem diameter, number of internodes, number of pods and number of seeds per pod. General plant behaviour was also observed to detect changes on a genic or chromosomic level. (M.A.C.) [pt

  6. Exposure buildup factors for a cobalt-60 point isotropic source for single and two layer slabs

    International Nuclear Information System (INIS)

    Chakarova, R.

    1992-01-01

    Exposure buildup factors for point isotropic cobalt-60 sources are calculated by the Monte Carlo method with statistical errors ranging from 1.5 to 7% for 1-5 mean free paths (mfp) thick water and iron single slabs and for 1 and 2 mfp iron layers followed by water layers 1-5 mfp thick. The computations take into account Compton scattering. The Monte Carlo data for single slab geometries are approximated by Geometric Progression formula. Kalos's formula using the calculated single slab buildup factors may be applied to reproduce the data for two-layered slabs. The presented results and discussion may help when choosing the manner in which the radiation field gamma irradiation units will be described. (author)

  7. Dose measurements for characterization of a semi-industrial cobalt-60 gamma-irradiation facility

    International Nuclear Information System (INIS)

    Farah, K.; Jerbi, T.; Kuntz, F.; Kovacs, A.

    2006-01-01

    Cobalt-60 irradiation facility has been put into operation at the National Centre of Nuclear Sciences and Technology, Sidi-thabet, Tunisia. Its technical specifications were controlled by dosimetry commissioning experiments and compared to the data specified by the plant manufacturer. Installation qualification has been carried out to measure absorbed dose distribution in the irradiation cell and products. Two dosimeter systems were used for measurements: Red and Amber Perspex and Cellulose Triacetate (CTA). The regions of minimum and maximum absorbed dose within a homogeneous dummy product (sawdust) with a bulk density of 114kg/m 3 and the dose uniformity ratio were determined. The isodose curves and the three-dimensional views were built using an automatic geostatistical gridding method, the kriging method

  8. Extension of the Commonwealth standard of absorbed dose from cobalt-60 energy to 25 MV

    International Nuclear Information System (INIS)

    Sherlock, S.L.

    1986-01-01

    With the introduction of high energy linear accelerators in hospitals, there is a need for direct measurement of absorbed dose for energies to 25 MV for photons and 20 MeV electrons. The present Australian standard for absorbed dose at cobalt-60 energy is a graphite micro-calorimeter maintained at the AAEC Lucas Heights Research Laboratories. A thorough theoretical analysis of calorimeter operation suggests that computer control and monitoring techniques are appropriate. Solution of Newton's law of cooling for a four-body calorimeter allows development of a computer simulation model. Different temperature control algorithms may then be run and assessed using this model. In particular, the application of a simple differencer is examined. Successful implementation of the calorimeter for energies up to 25 MV could lead to the introduction of an Australian absorbed dose protocol based on calorimetry, therby reducing the uncertainties associated with exposure-based protocols

  9. Disinfection of the bee hive's American Foulbrood by gamma radiation from Cobalt-60

    International Nuclear Information System (INIS)

    Gosselin, P.; Charbonneau, R.

    1990-01-01

    Gamma radiation from Cobalt-60 was used to sterilize honeybee combs contaminated by Bacillus larvae. The determination of the radiosensitivity (D 10 ) was done on cultured cells in Brain Heart Infusion broth and was found to be determined at 125 Gy. The D 10 of isolated spores from contaminated combs was then determined at 0,518 kGy and the D 10 of spores irradiated in their own original environment was found at 2,05 kGy. These treated combs were then sent back in the beehives. The bees cleaned the combs thoroughly and started the storage of honey in some cells. Eggs were also layed in others. Forty five days later, there were still no sing of re-appearance of the American Foulbrood disease. (author)

  10. Comparison of three methods for the calibration of cobalt-60 teletherapy machine

    International Nuclear Information System (INIS)

    Adewole, O.O.; Akinlade, B.I.; Oyekunle, O.E.; Ejeh, J.

    2011-01-01

    Two methods of indirect determination of dose rate (machine output) from the Cobalt-60 Teletherapy machines has been reviewed and compared with conventional measurement with dosimetry devices. The dose rate were determined by: (i) Conventional measurement (ii) Application of the law of radioactive decay and (iii) Assumption of 1 % radioactive decomposition per month. The dose rate at the depth of maximum dose (Z m ax), collimator size of 10cm x 10cm and Source to Skin Distance (SSD) of 80cm obtained from these methods were 203.7200cGy/min, 203.8090cGy/min and 203.9530cGy/min respectively. The ratio of dose rate obtained from measurement to that from calculations is within the tolerance value of 2%.

  11. On the application of a simple model of cobalt-60 beams

    International Nuclear Information System (INIS)

    Gantchew, M.G.

    1979-01-01

    The simple mathematical model of the dose distribution in a phantom irradiated by a single beam of cobalt-60 gamma rays (Wilks, R.J., and Sutcliffe, J.F., 1977, Phys. Med. Biol., vol. 22, 737) requires measurements for each particular field size and diaphragm setting to describe the decrement functions (dose distributions along a straight line perpendicular to the central ray). Measurements made with a Gammatron-3 have shown satisfactory agreement between computed and measured lateral dose distributions for different diaphragm settings if the experimental data was first subjected to additional processing, and Wilks and Sutcliffe's model can therefore be applied to any diaphragm setting using this modification. Field sizes can therefore be entered according to diaphragm indicator reading in dose planning. (U.K.)

  12. Perturbation of cobalt 60 radiation doses by metal objects implanted during oral and maxillofacial surgery

    International Nuclear Information System (INIS)

    Tatcher, M.; Kuten, A.; Helman, J.; Laufer, D.

    1984-01-01

    The influence on cobalt 60 dose distributions of typical metal parts used in oral and maxillofacial surgery was studied. Relative doses were determined by exposing x-ray films in a polystyrene phantom set-up containing samples of vitallium, titanium, and stainless steel. Optical densities were converted to doses with the aid of sensitometric curves. The results show that for normal incidence there is a 25% to 40% increase in dose at the entrance side of the metal and a 20% to 25% decrease in dose at the exit side. The enhancement effect falls off rapidly and becomes negligible at about 1 mm from the interface. The reduction effect decreases more gradually and is still evident at distances of a few centimeters. These dose perturbations should be taken into account in the planning of radiation therapy for patients in whom metal objects have been implanted

  13. Operational Qualification (OQ) Of MINTEC-Sinagama After Cobalt-60 Sources Replenishment

    International Nuclear Information System (INIS)

    Ruzalina Baharin; Hasan Sham; Ahsanulkhaliqin Abdul Wahab

    2014-01-01

    Activity on cobalt-60 sources replenishment at MINTec-Sinagama had been held in May 2014 with total strength of gamma as 440,000 Ci. Therefore, operational qualification (OQ) needs to be done in order to ensure that Sinagama plant is operating well and deliver suitable doses to the customer's products. In this work, three dose mapping exercises were carried out to establish dose distributions and dose reproducibility of plant, which are corresponded to the density of irradiator container (tote) and absorbed dose at normal operation. Dosimeters used were ceric cerous produced by SSDL, Malaysian Nuclear Agency and placed on three planes that represent three-dimensional array. They were located at certain intervals throughout the tote. This paper describes the OQ process and a bit touch on replenishment activity. (author)

  14. The Relation of Design Parameters, Plant Capacity and Processing Costs in Cobalt-60 Sterilization Plants

    International Nuclear Information System (INIS)

    Brown, M.G.

    1967-01-01

    The paper describes the main features of three basic types of cobalt-60 sterilization plants which have been designed to provide a complete range of capacities for radiosterilization of medical products. The smallest plant has a capacity of up to 50 000 cubic feet of medical products a year, the intermediate size plant has a capacity of up to 500 000 cubic feet a year, and the largest plant has a capacity in excess of 1000 000 cubic feet a year. The relations between capital costs, rate of production, efficiency and unit processing costs for each type of plant are discussed. The method of selecting the best type of plant for a particular need will also be outlined. (author)

  15. Formation of amino acids by cobalt-60 irradiation of hydrogen cyanide solutions

    Science.gov (United States)

    Sweeney, M. A.; Toste, A. P.; Ponnamperuma, C.

    1976-01-01

    Experiments were conducted to study the pathway for the prebiotic origin of amino acids from hydrogen cyanide (HCN) under the action of ionizing radiation considered as an effective source of energy on the primitive earth. The irradiations were performed in a cobalt-60 source with a dose rate of 200,000 rad/hr. Seven naturally occurring amino acids are identified among the products formed by the hydrolysis of gamma-irradiated solutions of HCN: glycine, alanine, valine, serine, threonine, aspartic acid, and glutamic acid. The identity of these amino acids is established by gas chromatography and mass spectrometry. Control experiments provided evidence that the amino acids are not the result of contamination.

  16. Biological fate of cobalt-60 released during the corrosion of neutron-activated stanless steel in seawater

    International Nuclear Information System (INIS)

    Young, J.S.

    1982-03-01

    Passing seawater over radioactive Type 347 stainless steel in a sediment/seawater laboratory system and exposing marine animals to this environment provided information on the bioaccumulation of 60 Co from radioactive structural material. Exposure of marine organisms to radioactive corrosion products and directly to radioactive stainless steel in seawater simulated some of the possible conditions which could arise from the deposition of radioactive stainless steel on the ocean floor. Detectable levels of 60 Co in marine animals were not observed on a short term basis (5 weeks). Longterm (13 months) exposure of marine animals in a sediment/seawater system resulted in 60 Co bioaccumulation. The specific activity of 60 Co in the organisms was as much as one million times less than that initially present in the radioactive stainless steel. This was due to the dilution of 60 Co by stable cobalt in the seawater, sediments and organisms. As expected the 60 Co specific activity of the organisms never increased above that of the radioactive source. This is because 60 Co is chemicaly indistinguishable from stable Co. Increasing 60 Co concentration factors with decreasing 60 Co concentrations in the seawater and sediment media coupled with relatively constant 60 Co specific activities suggest a possible homeostatic control of cobalt concentrations in certain marine organisms. The evidence indicates that the marine animals derived more of the accumulated 60 Co from the sediments and interstitial water than from seawater. Cobalt-60 concentration factors were generally found to be lower than published cobalt concentration factors due to the predominantly insoluble nature of the corrosion products. Baseline information is provided on trace element concentrations in deep-sea organisms. Stable Co and twenty other elements were measured in abyssal invertebrates and a fish

  17. Quarantine treatment for Sitophilus zeamais (Coleoptera: Curculionidae) through gamma radiation from Cobalt-60

    International Nuclear Information System (INIS)

    Ramos, Amanda Cristina Oliveira; Potenza, Marcos Roberto

    2009-01-01

    Pests like beetles, moths, fungus and mites normally attack stored products such as grains, spices, flours, brans and tobacco in bale. Among these pests the Sitophilus zeamais is one of the most important pests due its elevated potential of reproduction, infesting a great number of products, inducing great damages. This work had as objective to determine the efficacy of gamma radiation from Cobalt-60 as quarantine treatment for S. zeamais. The insects used in this experiment were reared in maize grains, at the Laboratorio de Artropodes of the Instituto Biologico/SP, on climatic room with 27 ± 2 deg C of temperature and relative humidity of 70 ± 5%. Samples containing 25 adult insects were put in acrylic recipients measuring 2.8cm x 2.8cm. Each treatment had four repetitions, in a total of 100 insects for treatment. They were irradiated with growing doses of gamma radiation: 0 (control); 0,25; 0,5; 0,75; 1,0; 1,25; 1,5; 1,75; 2,0; 2,25 2,5; 2,75; 3,0; 3,5 e 4,0 kGy, in a experimental irradiator of Cobalt-60, model Gammacell-220, located at the Centro de Tecnologia da Radiacoes - CTR of the Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN/SP. After irradiation, the samples were transferred to plastic recipients measuring 3,5cm x 10cm, with perforated lids (to allow gaseous exchanges). After the irradiation the samples were kept in climatic room (27 ± 2 deg C and 70 ± 5%). The mortality of insects was evaluated 1 hour after the irradiation and also on the next 7 days. By the results obtained we can conclude that was the dose of 2.75 kGy that induced the immediate mortality for adult insects of the specie S. zeamais. (author)

  18. Concrete Shielding For Radiation Safety And Unexpected Dangerous Inside Cobalt-60 Industrial Irradiator

    International Nuclear Information System (INIS)

    Keshk, A.B.; Aly, R.A.

    2011-01-01

    The study shows a proposed destruction inside one of three cobalt-60 industrial irradiators to determine and reduce the negative results, to improve and modify emergency plan to face terrorism works. The results show the performance of concrete shielding (walls and ceiling) contains the bad effect of dynamic pressures. The explosion forces are prevented to destructive by performance of their concrete shielding, which will contain the most components of devastated systems inside each irradiator after explosion. Shield penetration like electrical cable tunnels, pushers holes, hole with removable plug, product boxes openings, lens opening and ozone duct are affected badly by destruction. Through probability of transporting, some of devastated parts of broken radioactive cobalt- 60 pencils from inside radiation concreter room to outside (surrounded environment) are maintained and causing very danger radiation exposure by gamma rays outside irradiator. A necessity needs to modify emergency plan to prevent any explosive materials to enter inside the main building (irradiation sale) and also discovering any explosive materials which are placed inside the product boxes before passing to inside irradiator. The minimizing radiation exposure (2 mrem/h) inside underground radiation shelters are maintained by reducing radiation dose exerted from a nuclear explosion of 20 kT about 1 km away to a safe value, and calculating the protective factors of radiation main building basements are more than 40 (safety factor) as they are located under ground level, are surrounded by sandy soil and are constructed by concrete. The study shows the proposed basements of the main building maintain success to use as under ground safe radiation shelter (during emergency) with separate safe radiation trace. It begins from the main opening of irradiation sale and leads to underground proposed shelter through modified main stair

  19. Spontaneous carotid-cavernous sinus fistula disappeared following cobalt 60 irradiation. Case report

    Energy Technology Data Exchange (ETDEWEB)

    Satoh, Toru; Yamamoto, Yuji; Asari, Syoji (Matsuyama Shimin Hospital, Ehime (Japan))

    1983-12-01

    The authors reported a case of spontaneous carotid-cavernous sinus fistula fed by meningohypophyseal trunk of the internal carotid artery, that completely disappeared following cobalt 60 irradiation to the region of fistula (27 days; total dose, 4,100 rad). A 65-year-old man was admitted to our hospital on May 25, 1982, with a two-week history of progressive prominence of the left eye, diplopia on left lateral gaze, and continuous intracranial bruit. He first noted redness of the left eye without apparent cause such as head trauma. On admission, slight nonpulsative exophthalmos, periorbital edema, chemosis, and venous congestion of the conjunctiva of the left eye were noted. The pupils were reactive and equal in size, and the left abducent nerve palsy was observed. Fundoscopic examination disclosed to be normal. No bruit was heard over the left orbital region. Left carotid angiography on May 28 demonstrated dural internal carotid-cavernous sinus fistula fed by meningohypophyseal trunk, and drained into superior and inferior ophthalmic veins and basilar venous plexus. Though the patient was treated only conservatively, symptoms became worse to decrease visual acuity. On July 14, we started cobalt 60 irradiation to the region of fistula (27 days; total dose 4,100 rad). Symptoms gradually improved about halfway through irradiation. After completion of irradiation, almost complete improvement of visual and ocular symptoms was observed except the left abducent nerve palsy. Repeated angiography on Aug. 20 revealed complete disappearance of fistula. Three months after treatment, no recurrence of symptoms was observed and the abducent nerve palsy persisted without improvement.

  20. Microbiological Load Of Ethylene Oxide Sterilized Medical Devices And Its Elimination By Cobalt 60 Source

    International Nuclear Information System (INIS)

    Bashir, R.; Afroze, B.; Zulfiqar, H. F.; Saleem, R.; Saleem, F.; Aslam, F.; Naz, S.

    2016-01-01

    Objective: To determine the residing microbial flora of ethylene oxide (EtO) sterilized medical devices and optimization of safe dose of gamma radiation (Cobalt 60 source) for the complete elimination of microbial load. Study Design: Experimental study. Place and Duration of Study: Department of Biotechnology, Lahore College for Women University, Lahore, Pakistan from September 2014 to June 2015. Methodology: Thirty-six samples of EtO sterilized medical devices of same batch of three different companies were collected for this study. Isolation and enumeration of microbes were done by using different selective and differential media. Gram staining and biochemically characterization by API 20 (Bio Merieux, France) kit was done for identification of the microorganisms. The medical devices having high microbial load were sent to Pakistan Radiation Services (PARAS) for gamma irradiations at 3 different selected doses (20 KGy, 25 KGy, and 30 KGy). Result: Different types of Gram positive bacteria (Staphylococcus epidermidis, Staphylococcus aureus and Bacillus subtilis) were isolated from the EtO sterilized samples. Gram negative bacteria and fungi were not detected on these medical devices. Gamma irradiations Result showed that 30 KGy was optimized dose for complete elimination of microbial flora on endotracheal, Nelaton, and tracheostomy tubes. Conclusion: Gamma radiations (Co 60 source) effectively decontaminate the microbial flora on the equipment previously sterilized by the ethylene oxide gas; and 30 KGy is the optimized dose for all these medical devices. (author)

  1. Quarantine treatment in eggs of Stenoma catenifer Walsingham (Lepidoptera: Elachistidae), with gamma radiation of Cobalt-60

    International Nuclear Information System (INIS)

    Silva, L.K.F.; Arthur, V.; Nava, D.E.; Parra, J.R.P.

    2006-01-01

    The objective of this work has been to determine the lethal dose of gamma radiation of Cobalt-60 for the Stenoma catenifer eggs. For the irradiation of the eggs an irradiador Gammacell-220 (CO60) was utilized, (Rate dose: 1.054 kGY/h). The doses were: 0, 25, 50, 75, 100, 125 and 150 Gy, 90 eggs/dose (six repetitions). The number of caterpillars emerged was evaluated, and the survivors growed in seeds of avocado. The adults obtained were coupled with normal insects, growed in boxes with double face paper containing the food (10% honey) and a fruit of avocado. The experimental design was totally random, being the data submitted to the analysis of the varianza and the averages compared by the test of Tukey (P=5%). The emergence of caterpillars from the treated eggs with dose of 0, 25 and 50 Gy was verified. The dose of 50 Gy caused deformation in the caterpillars emerged. The effect of the gamma radiation in the viability of the eggs was proportional to the dose increase. The adults from the eggs dealt with 25 Gy presented non viabilty of 92,85 and 100% for male and female, respectively. A radiation gamma of 75 Gy is recommended for treatment quarantine for avocado fruits infested with of S. catenifer eggs

  2. The dosimetry of cobalt-60 γ-ray total body irradiation before bone marrow transplantation

    International Nuclear Information System (INIS)

    Dong Fan; Zhang Guiru

    1989-11-01

    The dosimetric considerations of using conventional cobalt-60 unit total body irradiation (TBI) are presented. By extending the source-to-midplane distance (SMD) to 346 cm, a 92 x 98 cm 2 rectangular field with diagonal dimension 134 cm was obtained. The results from the phantom measurements showed: (1) the effective field corresponding to an average-size patient is 25 x 25 cm 2 , and a method for estimating the effective field of human body is given; (2) the midplane doses are consistently higher than those of surfaces, but the dose ratio of midplane to surface decreases as the body thickness increases, and a significant negative correlation is existed between the dose ratio and thickness, thus a linear regression line is fitted; (3) the anterior-posterior (AP) or AP + bilateral irradiation will yield a more uniform dose distribution in the whole body than the bilateral irradiation; (4) the dose uniformity can apparently be improved by the tissue compensation, for which the technique is described

  3. HAW simulation experiments with cobalt-60 radiation sources in the Asse salt mine

    International Nuclear Information System (INIS)

    Rothfuchs, T.; Wieczorek, K.; Feddersen, H.K.

    1986-01-01

    The report describes the experimental work and the measured data of the joint German-American project for the HAW simulation experiment with cobalt-60 radiation sources in the Asse salt mine, covering the period up to the end of the third quarter 1986. The experiment is intended to yield information on the synergistic effects of heat and ionizing radiation on the salt rock under representative waste repository conditions. The investigations aim at the migration, release, and radiolytic decomposition of the water and gas components in the rock salt, and at the thermally induced strain and deformation processes. In addition, corrosion tests are planned to be made on various container test materials, and analyses of salt rock core samples for assessing the effect of heat and radiation on the rock. The report in hand presents all data obtained during the experiment. The results of the subsequent evaluation and verification studies will be presented in another report, the programme being given in an annex to the report in hand. (orig./RB) [de

  4. Evaluation of leakage in cobalt-60 unit in National Cancer Institute (NCI) Wad Medani

    International Nuclear Information System (INIS)

    Fadlellah, R. A.

    2013-08-01

    This study has been conducted primarily to evaluate the leakages radiation in cobalt-60 unit in National Cancer Institute Wad Medani, which represent the basic risky factor in this unit for the radio therapists who spend much time during patient set up, also they need to stand near the head of the machine to fix some accessories. The measurements which done using survey meter give normal level of occupational exposure compared with IAEA references except one situation that the radio therapist to be close contact to the head of unit for long time which may increase the received dose, in this situation. The radio therapist either not well trained, or there is insufficient accessories to reduce the time inside the room. Radiotherapy department need a special considerations from the beginning of construction till starting of treatment. It is important to contain separate rooms, for planning to determine treatment area, another one for molding to shape lead blocks to protect normal parts and an optimum designed room for treatment to enable workers to apply basic radiation protection principles. (Author)

  5. Effects of cobalt-60 low doses radiation on beam, rice and radish seeds

    International Nuclear Information System (INIS)

    Kikuchi, O.K.

    1987-01-01

    The effects of cobalt-60 gamma radiation on seeds of bean (Phaseolus vulgaris L.), rice (Oryza sativa L.) and radish (Raphanus sativus L.) were studied. Bean and rice seeds were irradiated with 3.5 and 7.7 Gy (32 Gy/h). There was an apparent acceleration on rice seed germination with 3.5 Gy when they were stored for 6 days after irradiation, but the same dose caused a delay when the store time was 1 day. Bean seeds germination was not modified by 3.5 and 7.7 Gy, but the fresh and dry weight of young plants showed an increase, mainly due the major quantity of water in the embryonic axis. Bean seeds were irradiated with 0.5 and 2.0 Gy (30 Gy/h). Seeds germination showed a slight delay irradiating with 0.5 Gy, while height, fresh and dry weight and primary leaves area of the young plants as well as number of nodes, leaves, flowers, beans and seeds were not modified after irradiation with 0.5 and 2.0 Gy. Radish seeds irradiated with 10 and 30 Gy at dose rates of 4.5, 22.5 and 45.0 Gy/h showed a germination delay and fresh and dry weight values for young plants leaves lower than control. Roots of totally developed plants showed no modifications in weight, volume, mean diameter, lenght and in the amount of soluble reducing sugar. (author)

  6. Reconstruction of exposures to the public from a cobalt-60 irradiator facility

    International Nuclear Information System (INIS)

    Chapman, T.E.; Scherpelz, R.I.

    1992-01-01

    A study was performed for the US Department of Energy (DOE) to assess the radiation exposure received by the public from the operation of a cobalt-60 irradiator facility. Located south of Davis, California, at the former Laboratory for Energy-Related Health Research, the facility was an indoor-outdoor gamma irradiator operated for the DOE by the University of California, Davis. From 1970 to 1985, outdoor radiation exposure experiments conducted at the facility resulted in environmental radiation doses of 80 to 120 mSv per year along the facility's perimeter fence. Comprehensive environmental monitoring was not performed in the adjacent, uncontrolled areas and personnel who occupied these areas were not routinely monitored for radiation exposure. Because of incomplete environmental monitoring data, computer modeling was required to reconstruct the environmental dose rates present when the facility was in operation. Personnel occupancy times for the adjacent areas were determined from population statistics, historical records, and personal interviews. The potential dose equivalents calculated for the individuals who lived or worked in neighboring areas ranged from 0.02 to 3.6 mSv per year. These exposures, some of which exceed the current DOE standard of 1 mSv/y, were less than the DOE regulatory limit of 5 mSv/y for exposure to the public that was in effect when the facility was in operation

  7. Preoperative cobalt60 irradiation delays the healing of rectal anastomoses in rats

    International Nuclear Information System (INIS)

    Fang, C.B.; Klug, W.A.; Capelhuchnik, P.

    2005-01-01

    The healing of colorectal anastomoses after irradiation therapy continues to be a major concern. The authors evaluated the healing of rectal anastomoses in a rat model after a preoperative 500-c Gy dose of cobalt 60 irradiation. Thirty-six male Wistar rats were divided into two equal groups: control (group A), and irradiation group (group B). Group B received a single 500-c Gy dose of irradiation, and a rectal resection and end-to-end anastomosis was performed in both groups on the seventh day after irradiation. Parameters of the healing process included bursting pressure and collagen content on the fifth, seventh, and fourteenth days after surgery. In the irradiation group, the mean bursting pressure on the fifth, seventh, and fourteenth days was 116, 218, and 273 mmHg, respectively. The collagen content assessed by histomorphometry was 9.0, 20.8, and 32%, respectively. In contrast, the control group had a mean bursting pressure of 175, 225 and 263 mmHg, and a collagen content of 17.8, 28.1, and 32.1%, respectively. The adverse effect of irradiation on healing was detectable only on the fifth postoperative day, as demonstrated by lower bursting pressure (P < 0.013) and collagen content (P < 0.008). However, there was no failure of anastomotic healing such as leakage or dehiscence due to irradiation. We conclude that a single preoperative 500-c Gy dose of irradiation delays the healing of rectal anastomosis in rats. (author)

  8. Preoperative cobalt{sup 60} irradiation delays the healing of rectal anastomoses in rats

    Energy Technology Data Exchange (ETDEWEB)

    Fang, C.B.; Klug, W.A.; Capelhuchnik, P. [Santa Casa de Misericordia de Sao Paulo, SP (Brazil). Faculdade de Ciencias Medicas. Dept. de Cirurgia]. E-mail: colon.reto@terra.com.br

    2005-06-15

    The healing of colorectal anastomoses after irradiation therapy continues to be a major concern. The authors evaluated the healing of rectal anastomoses in a rat model after a preoperative 500-c Gy dose of cobalt 60 irradiation. Thirty-six male Wistar rats were divided into two equal groups: control (group A), and irradiation group (group B). Group B received a single 500-c Gy dose of irradiation, and a rectal resection and end-to-end anastomosis was performed in both groups on the seventh day after irradiation. Parameters of the healing process included bursting pressure and collagen content on the fifth, seventh, and fourteenth days after surgery. In the irradiation group, the mean bursting pressure on the fifth, seventh, and fourteenth days was 116, 218, and 273 mmHg, respectively. The collagen content assessed by histomorphometry was 9.0, 20.8, and 32%, respectively. In contrast, the control group had a mean bursting pressure of 175, 225 and 263 mmHg, and a collagen content of 17.8, 28.1, and 32.1%, respectively. The adverse effect of irradiation on healing was detectable only on the fifth postoperative day, as demonstrated by lower bursting pressure (P < 0.013) and collagen content (P < 0.008). However, there was no failure of anastomotic healing such as leakage or dehiscence due to irradiation. We conclude that a single preoperative 500-c Gy dose of irradiation delays the healing of rectal anastomosis in rats. (author)

  9. Induced chlorophyll variation in pineapple c v. 'queen' by gamma irradiation (60Cobalt)

    International Nuclear Information System (INIS)

    Valencia, Lolita DC.

    2012-01-01

    Irradiation using gamma rays ( 60 Cobalt) coupled with in vitro culture techniques was undertaken to induce variation or mutation in pineapple. Calli from crown meristem tips of pineapple cv 'Queen' [Ananas comosus (L.) Merr.] were initiated using Murashiege and Skoog's basal meduim supplemented with 10mg/liter 4-amino-3,5,6-trichloro-2-pyrodinecarboxylic acid (Picloram). High percentage of growth and shoot proliferation was observed in basal medium supplemented with 50 μM benzene adenine purine (BAP) and 10 μM gibberrelic acid (GA) after 8 weeks in vitro. Regenerants derived from shoots using different doses of gamma rays (0, 5, 10, 15, 20, 25 and 30 Gy) were evaluated under laboratory conditions. Of the different doses, 15 Gy produced the most variegation in young shoots (chlorophyll variants) maintained in vitro. The variants appeared to have yellow and green color combinations of the young leaves of pineapple 'Queen' variety. When transplanted inside the greenhouse, high percentage of plantlets survival was observed, ranging from 90-95%. Of the different irradiation doses, variegation in young leaves was observed at 15, 20, 25 and 30 Gy. Further assessment on the effect of irradiation is currently being unertaken under screen house conditions. The variants produced could serve a basis for selection of ornamental-type pineapple. In addition, protocols developed on the use of in vitro culture techniques could be utilized as a tool for induced mutation breeding in pineapple. (author)

  10. An athymic mouse model to mimic cobalt-60 cutaneous radiation injury

    Energy Technology Data Exchange (ETDEWEB)

    Mosca, Rodrigo Crespo; Ferreira, Danilo Cardenuto; Napolitano, Celia Marina; Santin, Stefany Plumeri; Dornelles, Leonardo Dalla Porta; Alvarenga, Eluara Ortigoso; Mathor, Monica Beatriz, E-mail: rcmosca@usp.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2013-07-01

    Propose: Cutaneous wound from irradiation is the most common complication in radiotherapy treatment, and can be lead to mortality. We describe an athymic mouse model to mimic cutaneous radiation injury by Cobalt-60. Methods: A protocol was including dosimetry with silicon diodes,10x10x5 cm arrangement made by four lead bricks and PVC pipe designed to immobilize the athymic mouse in order to irradiate one clamped back skin point that was subdivided in four parts. To get the measurements of dose rates on the arrangement in Panoramic Irradiator, it was used a silicon diode encased in an opaque protection for ambient light and connected to an electric cable, forming a dosing probe. The currents generated in diode sensitive volume as a function of time of exposure to gamma radiation coming from the radiator, with dose rate of 0,015 Gy/min in positions 1, 0,021 Gy/min in position 2, 0,55 Gy/min in position 3 and 1,45 Gy/min in position four. After the dosimetry, each athymic mouse was anesthetized using Xylazine and Ketamine dilution and entered into a PVC pipe and a small portion of skin (1 cm{sup 3}) was clamped. This tube was then fixed to arrangement and the athymic mouse was irradiate for 60 min, than it was being returned to its cage. Results: The wound was visualized in all animals and photographed after 5 days of irradiation, with the emergence of ulceration after 9 days. No systemic or lethal sequelae occurred or visualized in any animals. Late clinical signs included a wound healing after 22 days. Conclusion: While still being a baseline study, we created a new functional preclinical animal model that can be used for new therapies and may improve radiotherapy management. (author)

  11. An athymic mouse model to mimic cobalt-60 cutaneous radiation injury

    International Nuclear Information System (INIS)

    Mosca, Rodrigo Crespo; Ferreira, Danilo Cardenuto; Napolitano, Celia Marina; Santin, Stefany Plumeri; Dornelles, Leonardo Dalla Porta; Alvarenga, Eluara Ortigoso; Mathor, Monica Beatriz

    2013-01-01

    Propose: Cutaneous wound from irradiation is the most common complication in radiotherapy treatment, and can be lead to mortality. We describe an athymic mouse model to mimic cutaneous radiation injury by Cobalt-60. Methods: A protocol was including dosimetry with silicon diodes,10x10x5 cm arrangement made by four lead bricks and PVC pipe designed to immobilize the athymic mouse in order to irradiate one clamped back skin point that was subdivided in four parts. To get the measurements of dose rates on the arrangement in Panoramic Irradiator, it was used a silicon diode encased in an opaque protection for ambient light and connected to an electric cable, forming a dosing probe. The currents generated in diode sensitive volume as a function of time of exposure to gamma radiation coming from the radiator, with dose rate of 0,015 Gy/min in positions 1, 0,021 Gy/min in position 2, 0,55 Gy/min in position 3 and 1,45 Gy/min in position four. After the dosimetry, each athymic mouse was anesthetized using Xylazine and Ketamine dilution and entered into a PVC pipe and a small portion of skin (1 cm 3 ) was clamped. This tube was then fixed to arrangement and the athymic mouse was irradiate for 60 min, than it was being returned to its cage. Results: The wound was visualized in all animals and photographed after 5 days of irradiation, with the emergence of ulceration after 9 days. No systemic or lethal sequelae occurred or visualized in any animals. Late clinical signs included a wound healing after 22 days. Conclusion: While still being a baseline study, we created a new functional preclinical animal model that can be used for new therapies and may improve radiotherapy management. (author)

  12. Radiological safety aspects during handling of adjuster rod (cobalt-60) samples at Cirus

    International Nuclear Information System (INIS)

    Yadav, R.K.B.; Prasad, S.K.; Khuspe, R.R.; Babu, K.S.; Kamble, M.K.; Deshpande, S.B.; Srivastava, Alok; Ramesh, N.; Sharma, R.C.

    2008-01-01

    Cobalt -60 produced from the irradiation of the 59 Co capsules in adjuster rod of Cirus is used in many medical and industrial applications such as radiation therapy, sterilization of agricultural products, sterilization of medical equipment, industrial gamma exposure devices, nucleonic gauging sources etc. Two adjuster rods used for adjusting small reactivity loads (3.5 mk at 40 MW) in reactor contain thirty 59 Co slugs each. The 59 Co slugs are in the form of small capsules. These slugs were irradiated for nearly 3 years of full power operation. Since the amount of activity handled in the adjuster rod is very high (35 - 40 kCi), adequate radiological safety coverage is to be provided during the transfer of adjuster rod from the reactor pile to Tray Rod Facility (TRF) and during remote handling and loading of adjuster rod samples in shipping flask at TRF. Radiation fields observed are 0.4 - 3.0 Gy/h. In Cirus, falling of Adjuster rod from vertical flask at top of pile could result in declaration of evacuation emergency due to potential hazards associated with the high radiation field (∼26 Gy/h at 1m) of 60 Co slugs. Entire process of remote handling is viewed through lead glass and movement of samples is carried out with the help of a pair of master slave manipulator (MSM) arms. TRF with full samples give a radiation background of 0.2 - 20 mGy/h, requiring control of movement of personnel in the area. This paper explains in detail about the health physics aspects during handling of adjuster rod from reactor pile to TRF and back to pile, unloading and loading of radioisotope samples, operational radiation protection experience gained and collective dose consumed for the above transfer and loading job. The collective dose consumed in the handling of two adjuster rods is 8.7 per-mSv. (author)

  13. Regression of uveal malignant melanomas following cobalt-60 plaque. Correlates between acoustic spectrum analysis and tumor regression

    International Nuclear Information System (INIS)

    Coleman, D.J.; Lizzi, F.L.; Silverman, R.H.; Ellsworth, R.M.; Haik, B.G.; Abramson, D.H.; Smith, M.E.; Rondeau, M.J.

    1985-01-01

    Parameters derived from computer analysis of digital radio-frequency (rf) ultrasound scan data of untreated uveal malignant melanomas were examined for correlations with tumor regression following cobalt-60 plaque. Parameters included tumor height, normalized power spectrum and acoustic tissue type (ATT). Acoustic tissue type was based upon discriminant analysis of tumor power spectra, with spectra of tumors of known pathology serving as a model. Results showed ATT to be correlated with tumor regression during the first 18 months following treatment. Tumors with ATT associated with spindle cell malignant melanoma showed over twice the percentage reduction in height as those with ATT associated with mixed/epithelioid melanomas. Pre-treatment height was only weakly correlated with regression. Additionally, significant spectral changes were observed following treatment. Ultrasonic spectrum analysis thus provides a noninvasive tool for classification, prediction and monitoring of tumor response to cobalt-60 plaque

  14. Effects of cobalt-60 ionizing radiation on human erythrocyte and its membrane proteins

    International Nuclear Information System (INIS)

    Amancio, Francisco Fernandes

    1998-01-01

    Ionizing radiation has several uses, as sterilization and radiotherapy, by its effects on living beings. recently, it has been used, at relatively lower doses (25 Gy), on blood for transfusions, mainly to eliminate undesirable graft host reactions, for use in multi transfused or immunocompromised patients. Here, we study the effect of larger doses of cobalt-60 ionizing radiation (25-1600 Gy) on human erythrocytes, by cytometric, physiologic, biochemical and immunological methods, looking for its effects and its detection. The red cells presented a clear dose-dependent increase in this volume, when irradiated in doses higher than 200 Gy, more significant in stored blood, but without hemolysis. Osmotic fragility was increased only after irradiation of more than 400 Gy. By ektacytometry, there was a lower deformability of irradiated red cells, at low stress (0.3 Pa), similar to capillary flow, but without alteration in higher stress (3 Pa), found in cardiac chambers. By SDS-PAGE, it was demonstrated that irradiated isolated erythrocyte membranes had aggregation of spectrin molecules, and decay of bands with lower molecular mass. This effect could be attributed to the radiation-induced hydroxyl radical, by specific scavenger studies. Those modifications were both antigenic and immunogenic in experimental animals, and the induced antibodies recognizes, by ELISA and immunoblot, both native or irradiated membrane proteins. They recognize rather irradiated whole erythrocyte than native ones, by hemagglutination, indirect immunofluorescence or flow cytometry assays. Our data suggests that human red cells could be irradiated at higher doses than those usually employed, with possible effect on other contaminant pathogens, without loss of viability of its use in transfusions. After improvements, irradiation induced epitopes detection could be a new tool in biological dosimetry. (author)

  15. Degradation of the insecticide ethyl parathion in different environmental matrices by gamma radiation from Cobalt-60

    International Nuclear Information System (INIS)

    Luchini, Luiz Carlos

    1995-01-01

    This work studies the use of gamma radiation from cobalt-60 to induce parathion degradation in different matrices, as well as, quantified GC-NPD and identified by GC-MS, the radiolysis resulting products. Results show that the insecticide was completely degraded in aqueous solution after treatment with 1.0 kGy dosis in a dosis rate of 3.12 kGy h -1 . In methanol, parathion was completely degraded only with 30 kGy at 3.12 kGy h -1 . The metabolites detected after radiolysis were the same formed by biological degradation, i.e, p-nitrophenol, p-aminophenol, paraoxon and aminoparathion. The gamma radiation also degraded paraoxon which is the most toxic metabolite of parathion. It was verified that, not only the total radiation, but also the dosis rate supplied to the aqueous solution had a significant effect on the insecticide degradation, and the formation of metabolites occurred in a selective way respecting the dosis and dosis rate. Otherwise, the gamma radiation did almost not degraded the parathion adsorbed in solid matrices as rice, moist and dry soil, even using dosis of 5,30 and 50 kGy, respectively. The parathion yield and the dosis of gamma radiation needed for 50% reduction of the insecticide initial concentration in aqueous solution were also calculated and presented. Thus, it was verified that irradiation of parathion besides to be an important instrument for environmental decontamination of this pesticide in aqueous matrix, it allows the production of parathion metabolites for ecotoxicological studies. (author)

  16. Late effects of protracted whole-body irradiation of beagles by cobalt-60 gamma rays

    International Nuclear Information System (INIS)

    Fritz, T.E.; Seed, T.M.; Tolle, D.V.; Lombard, L.S.

    1986-01-01

    So that a stronger basis for extrapolation of low-level radiation effects to man can be provided, existing data from small laboratory animals are being supplemented by studies in a longer lived animal, the dog. Beagle dogs are exposed to continuous cobalt-60 irradiation either throughout life or until predetermined total doses are accumulated. The radiation-specific excess-mortality rate and associated causes of death will be related to both dose rate and total dose. The ongoing studies also emphasize the pathogenesis of myelogenous leukemia. At dose rates of 3.75 to 26.25 rads/day, given continuously, responses were consistent, highly dose-rate dependent, and limited primarily to the hematopoietic system. At rates as low as 0.3 rad/day, the hematopoietic system is still the limiting factor for survival, but below 3.75 rads/day present evidence suggests that the responses are independent of dose rate. Longitudinal studies of peripheral blood and bone marrow detected four preclinical phases of myelogenous leukemia. These phases were characterized by standard hematologic end points, ultrastructural features, in vitro cloning assays, and the acute radiation sensitivity of stem cells. Results suggest that an induced error-prone repair mechanism is the basis for the onset of radiation-induced myelogenous leukemia. Interim data from dogs given terminated exposures suggest that the types of tumors and times to death are different from controls but the numbers of tumors are not yet greater than in controls. 26 refs., 12 figs., 5 tabs

  17. Cytogenetic characterization of low-dose hyper-radiosensitivity in Cobalt-60 irradiated human lymphoblastoid cells

    Energy Technology Data Exchange (ETDEWEB)

    Joshi, Gnanada S. [Department of Biological Sciences, Wayne State University, Detroit, MI 48202 (United States); Joiner, Michael C. [Department of Radiation Oncology, Wayne State University, Detroit, MI 48201 (United States); Tucker, James D., E-mail: jtucker@biology.biosci.wayne.edu [Department of Biological Sciences, Wayne State University, Detroit, MI 48202 (United States)

    2014-12-15

    Highlights: • Human cells were irradiated in G1 or G2 and evaluated for micronuclei and bridges. • Cells irradiated in G2 but not in G1 exhibit low dose hyper-radiosensitivity. • Response curves of cells irradiated in G2 do not fit a linear-no-threshold model. • Response curves of cells irradiated in G1 fit a linear-no-threshold model. - Abstract: The dose-effect relationships of cells exposed to ionizing radiation are frequently described by linear quadratic (LQ) models over an extended dose range. However, many mammalian cell lines, when acutely irradiated in G2 at doses ≤0.3 Gy, show hyper-radiosensitivity (HRS) as measured by reduced clonogenic cell survival, thereby indicating greater cell lethality than is predicted by extrapolation from high-dose responses. We therefore hypothesized that the cytogenetic response in G2 cells to low doses would also be steeper than predicted by LQ extrapolation from high doses. We tested our hypothesis by exposing four normal human lymphoblastoid cell lines to 0–400 cGy of Cobalt-60 gamma radiation. The cytokinesis block micronucleus assay was used to determine the frequencies of micronuclei and nucleoplasmic bridges. To characterize the dependence of the cytogenetic damage on dose, univariate and multivariate regression analyses were used to compare the responses in the low- (HRS) and high-dose response regions. Our data indicate that the slope of the response for all four cell lines at ≤20 cGy during G2 is greater than predicted by an LQ extrapolation from the high-dose responses for both micronuclei and bridges. These results suggest that the biological consequences of low-dose exposures could be underestimated and may not provide accurate risk assessments following such exposures.

  18. Effects of whole-body cobalt 60 gamma irradiation on the young korean native goats

    International Nuclear Information System (INIS)

    Kim, Jong Gyu; Sung, Jai Ki

    1989-01-01

    This study was carried out to investigate the effects of whole-body cobolt-60 gamma irradiation on clinical signs, mortality, hematological, blood chemical, chromosomal and pathologic changes in the young Korean native goats. Groups of goats were exposed to 200, 400, 600 and 800 rads of gamma irradiation from a cobalt-60 source. Clinical signs such as diarrhea, anorexia, weakness and depression of the irradiated goats were observed. Mortalities were 66.7 percent in the group irradiated with 200 rads and 100 percent in the groups irradiated with higher doses. Death times were shortened with the increment of irradiation doses. With time after irradiation, the values of erythrocytes, hemoglobin and packed cell volume decreased in the 200 and 400 rads groups and increased in the 600 and 800 rads groups. The number of total leukocytes of the irradiated goats decreased significantly in all irradiated groups. The degrees of decrease were severe as the irradiated doses were increased. Significant decrease of lymphocyte counts were observed from 6 hours in the 800 rads group and 1 day post irradiation(PI) in all other groups. Post irradiation times for significant reduction of neutrophils were 1, 3, 3 and 5 days for 800, 600, 400 and 200 rads groups, respectively. Serum sorbitol dehydrogenase and serum aspartate aminotransferase activities increased remarkably at 6 hours PI in the 800 rads group and 1 day PI in all other groups. Thereafter the activities returned to normal values. Since mitoses of lymphocytes were completely inhibited in blood cultures of all irradiated goats, chromosomal pictures could not be observed. However, mitoses were observed on 28 days PI in 200 rads group and no abberration in the number and structures of lymphocyte chromosomes were detected. Histopathologic findings in various organs of the irradiated goats were severe necrosis and depletion of lymphoid cells in the lymph nodes and spleen, hypoplasia of hemopoietic cells in the bone marrow

  19. Autonomous monitoring unit, signs and registration for Cobalt-60 irradiator safety system

    Energy Technology Data Exchange (ETDEWEB)

    Baldaconi, Ricardo H.; Costa, Fabio E. da, E-mail: ricardohovacker@hotmail.com, E-mail: fecosta@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2015-07-01

    The Cobalt-60 irradiator of IPEN / CNEN, a category IV facility, has a security system for inter locking doors or exposure of radioactive sources made simultaneously by a programmable logic controller (PLC) model S7- 200 from Siemens and a relay logic. From a set of information, the both systems work together opening doors or exposing the sources. All incoming and outgoing information are sent serially via EIA232 communication to a personal computer with Windows® platform for a supervisory program which provides besides a monitoring the entire process by a synoptic table on the computer screen, also keeps records of all events on the computer's hard drive. The electronic management has proven to be efficient and has not produced any failure that had compromised the safety. The PLC along with the relay logic has always taken the right decisions ensuring proper radiation protection of operators and the integrity of radioactive sources, but it presented over the years of operation (beginning in 2004) less than a dozen flaws in system event log. The deficiency was found between the process of sending events via serial communication (EIA232) to the supervisory program. When failure occurs in a very short time, the PLC always took the right decision, but the registration process that had to go through the Windows® timeshare lost the information. This work aimed to build a standalone electronics connect the inputs and outputs of the security system, fully optocoupled to avoid any interference to the security system. It records each event on a memory card, waits for the right decision of the security system and in case of an incorrect decision an independent alarm notifies its own synoptic picture, and sends a text message to a group of defined cell phones. The circuit uses two microcontrollers called 'main' and 'secondary'. The main is responsible for the control and monitoring of peripheral inputs and outputs of the security system. The main is

  20. Autonomous monitoring unit, signs and registration for Cobalt-60 irradiator safety system

    International Nuclear Information System (INIS)

    Baldaconi, Ricardo H.; Costa, Fabio E. da

    2015-01-01

    The Cobalt-60 irradiator of IPEN / CNEN, a category IV facility, has a security system for inter locking doors or exposure of radioactive sources made simultaneously by a programmable logic controller (PLC) model S7- 200 from Siemens and a relay logic. From a set of information, the both systems work together opening doors or exposing the sources. All incoming and outgoing information are sent serially via EIA232 communication to a personal computer with Windows® platform for a supervisory program which provides besides a monitoring the entire process by a synoptic table on the computer screen, also keeps records of all events on the computer's hard drive. The electronic management has proven to be efficient and has not produced any failure that had compromised the safety. The PLC along with the relay logic has always taken the right decisions ensuring proper radiation protection of operators and the integrity of radioactive sources, but it presented over the years of operation (beginning in 2004) less than a dozen flaws in system event log. The deficiency was found between the process of sending events via serial communication (EIA232) to the supervisory program. When failure occurs in a very short time, the PLC always took the right decision, but the registration process that had to go through the Windows® timeshare lost the information. This work aimed to build a standalone electronics connect the inputs and outputs of the security system, fully optocoupled to avoid any interference to the security system. It records each event on a memory card, waits for the right decision of the security system and in case of an incorrect decision an independent alarm notifies its own synoptic picture, and sends a text message to a group of defined cell phones. The circuit uses two microcontrollers called 'main' and 'secondary'. The main is responsible for the control and monitoring of peripheral inputs and outputs of the security system. The main is

  1. Flux perturbation factor in cobalt samples for the reactor production of Co-60

    International Nuclear Information System (INIS)

    Curzio, O.A.

    1976-07-01

    Total flux perturbation factor (F) is experimentally determined for hollow cylinder cobalt samples irradiated in the RA-3 reactor. F factor is studied for different thicknesses of the material and the values are compared with those theoretically estimated by Dwork for a similar. (author) [es

  2. Separation of iron and cobalt using 59Fe and 60Co by dialysis of polyvinylpyrrolidone-metal complexes: A greener approach

    International Nuclear Information System (INIS)

    Lahiri, Susanta; Sarkar, Soumi

    2007-01-01

    An environmentally benign method to separate iron and cobalt has been developed using a safe chemical, polyvinylpyrrolidone (PVP). The method involves dialysis of PVP-Fe and PVP-Co complexes against triple-distilled water. 59 Fe and 60 Co were used as radioactive tracers of iron and cobalt throughout the experiment. No other chemicals are required for clean separation of cobalt from iron. The optimum condition for separation has been obtained at pH 5 using 10% aqueous solution of PVP. The method is applicable from trace scale to macro-scale. Very high separation factors have been obtained

  3. Evaluation of shelf life of tomatoes after using radiation with cobalt-60 source

    International Nuclear Information System (INIS)

    Vicalvi, Maria Claudia V.; Solidonio, Evelyne G.; Melo, Patryk; Silva, Marcio Albuquerque da; Junior, Carlos Eduardo de O.C.; Silva, Glezia Renata da; Sena, Kesia Xisto F.R. de; Colaco, Waldeciro

    2013-01-01

    Tomato is one of the most consumed fruits in the world and also one of the agricultural products with most losses due to its high perishability. The objective of this research was to evaluate the increased length of shelf life of tomatoes sold in the CEASA-PE through the use of radiation in doses of 1, 1.5 and 2 kGy with Cobalt-60 source. The study used three lots of 100 tomatoes each. Of which, 25 of them were used as the control group and 75 were irradiated with one of 3 different doses. The evaluation of the shelf life of tomatoes before and after use of the radiation was made from the observation of the visual aspects of the initiation of the fruit sto decay. The samples were analyzed at of every seven days. The fruit treated as the control group of the first batch were viable with no signs of decay for more than one month wrapped in sterile plastic wrap and stored at environment temperature ± 25 deg C. It was observed that at the dose of 1.0 kGy there was a delay in the induction of shelf life over 14 days. When used a dose of 1.5 kGy there was an increase of 30 days on shelf life compared with the control group. At a dose of 2.0 kGy, the tomatoes have a shelf life of 92 days. In the second batch of fruits, the duration of tomatoes of the control group was 40 days. At a dose of 1.0 kGy was an increase of 15 days compared to control fruits. When applying the dose of 1.5 kGy, the lifetime of the fruit was 70 days and at the dose of 2.0 kGy fruits were of 106 days starting from the initial date of experiment. The third and final batch,the lifetime of the fruits were not higher than those found in previous batches, the control group had a permanence of 14 days. At the dose of 1.0 kGy, there was the additional 10 days compared to the control group. At a dose of 1.5 kGy was observed that the fruits lasted 35 days starting from the initial day of the experiment and the tomatoes that were irradiated at 2.0 kGy the duration was 45 days from the start date of the

  4. Evaluation of shelf life of tomatoes after using radiation with cobalt-60 source

    Energy Technology Data Exchange (ETDEWEB)

    Vicalvi, Maria Claudia V.; Solidonio, Evelyne G.; Melo, Patryk; Silva, Marcio Albuquerque da; Junior, Carlos Eduardo de O.C.; Silva, Glezia Renata da; Sena, Kesia Xisto F.R. de; Colaco, Waldeciro, E-mail: claudiavicalvi@hotmail.com, E-mail: k.xisto@gmail.com, E-mail: wcolaco@ufpe.com.br [Universidade Federal de Pernanbuco (UFPE), Pernambuco, PE (Brazil)

    2013-07-01

    Tomato is one of the most consumed fruits in the world and also one of the agricultural products with most losses due to its high perishability. The objective of this research was to evaluate the increased length of shelf life of tomatoes sold in the CEASA-PE through the use of radiation in doses of 1, 1.5 and 2 kGy with Cobalt-60 source. The study used three lots of 100 tomatoes each. Of which, 25 of them were used as the control group and 75 were irradiated with one of 3 different doses. The evaluation of the shelf life of tomatoes before and after use of the radiation was made from the observation of the visual aspects of the initiation of the fruit sto decay. The samples were analyzed at of every seven days. The fruit treated as the control group of the first batch were viable with no signs of decay for more than one month wrapped in sterile plastic wrap and stored at environment temperature ± 25 deg C. It was observed that at the dose of 1.0 kGy there was a delay in the induction of shelf life over 14 days. When used a dose of 1.5 kGy there was an increase of 30 days on shelf life compared with the control group. At a dose of 2.0 kGy, the tomatoes have a shelf life of 92 days. In the second batch of fruits, the duration of tomatoes of the control group was 40 days. At a dose of 1.0 kGy was an increase of 15 days compared to control fruits. When applying the dose of 1.5 kGy, the lifetime of the fruit was 70 days and at the dose of 2.0 kGy fruits were of 106 days starting from the initial date of experiment. The third and final batch,the lifetime of the fruits were not higher than those found in previous batches, the control group had a permanence of 14 days. At the dose of 1.0 kGy, there was the additional 10 days compared to the control group. At a dose of 1.5 kGy was observed that the fruits lasted 35 days starting from the initial day of the experiment and the tomatoes that were irradiated at 2.0 kGy the duration was 45 days from the start date of the

  5. Effects of gamma radiation from Cobalt-60 on pequi fruits (Caryocar brasiliense Camb.)

    International Nuclear Information System (INIS)

    Santos, Marcio Ramatiz Lima dos

    2008-01-01

    The aim of this work was to evaluate gamma radiation effects from Cobalt-60 on post harvest characteristics of pequi fruits (Caryocar brasiliense Camb.). Brazilian savannah is the second biome of American Continent and concentrate a lot of plants and animal species. Many plants and their fruits are still unknown of Brazilian population. Just now, they are gained attention of researchers due their nutritional properties, between then is the pequi fruits. Fruits come from Goias State was classified, washed and processed to separate the endocarp (edible part) from pericarp. The endocarps were packing in polyethylene bags with 150 g, labeled and submitted to radiation process (0.0, 0.4, 0.6 and 1.0 kGy doses) on multipurpose irradiator located in IPEN/USP. The samples were analyzed to chemical (pH, trititable acidity, Deg Brix, ratio TSS/TTA, lipids, ash, humidity, protein, soluble and insoluble fiber, total carotenoids and antioxidant activity) and physical properties (loss weight, texture and color). The loss humidity was proportional to radiation applied doses, the highest loss was observed on fruits to 1.0 kGy doses. Soluble fiber and protein showed no significant differences between treatments. Ash, insoluble fiber, dry matter and lipids showed little significant differences. Significant decrease of the pH values was observed for the irradiated samples in relation to control. Irradiated samples texture showed significant increase compared to control, but showed no significant differences between applied doses. The higher value for texture was (39.89 Newton g-1) for 0.6 kGy dose. Total soluble solids (TSS) showed a significant decrease compared to control, but was not significant between applied treatments. Titratable acidity showed a significant decrease for irradiated samples compared to control for all doses, but it was not significant between treatments. The ratio TSS/TTA showed no significant differences compared to control, only for irradiated fruits at 0.6 k

  6. Effects of gamma radiation from Cobalt 60 on eggs and adults of Sitotroga cerealella (Oliver, 1819) (Lepidoptera, Gelechiidae) in laboratory

    International Nuclear Information System (INIS)

    Rodrigues, Z.A.; Rego, A.M.; Oliveira, M.L. de; Ferreira, D.

    1983-01-01

    Lethal and sterilizing dosages from Cobalt-60 radiations were determined for Sitotroga cerealella (Oliver, 1819) eggs and adults. Eggs at the age of 0 to 24 hours were irradiated with dosages of 0,1,2; 4,6,8,10 and 12 krad; it was observed that 10 krad killed all embryos although this was not observed in 96 hours old eggs. A new group was irradiated with dosages of 0,60,80,100,120 and 140 krad, and complete lethal dosage was determined as 140 krad. Mating of irradiated with non irradiated insects resulted in 100% infertile eggs when either the males or females had received the dosage of 100 krad. Imediate lethality of S. cerealella adults was not observed with the dosages of 300 to 320 krad but all insects died after two days (L sup(D) 100/ 2 ). (Author) [pt

  7. Uptake of cobalt-60 from sea water and from labelled food by the common shrimp Crangon erangon (L.)

    International Nuclear Information System (INIS)

    Weers, A.W. van

    1975-01-01

    The role of two different modes of uptake in the accumulation of 60 Co by the common shrimp (Crangon crangon (L.)) is the subject of the present study. The results show that accumulation of 60 Co from sea water is a slow process. The concentration factor for whole animals reached in one month was only about 13. Most of the activity accumulated from water appears to be associated with the exoskeleton. As a consequence, moulting has a pronounced effect on the uptake pattern of 60 Co and on the subsequent retention of the radionuclide by shrimps kept in non-radioactive sea water. After single feeding of shrimps with labelled mussel flesh, 60 Co is retained according to an exponential function with a short-lived and a long-lived component. The short-lived component has a mean biological half-life of 1.2 days and accounts for about 80% of the initial activity. About 20% of the initial activity is lost with a mean biological half-life of about 10 days. After repeated feeding of labelled mussel flesh the short-lived component in the 60 Co retention is virtually absent. Cobalt-60 taken up with food is localized mainly in the digestive gland and the concentration in the edible muscles from the abdomen is relatively small. It is concluded from the present study that direct uptake from sea water will play only a minor role in the accumulation of 60 Co in the internal organs of the shrimp. 60 Co released into the marine environment will be taken up by shrimps mainly from food. The results indicate a rapid turnover of 60 Co in shrimps. (author)

  8. Sci-Thur PM – Brachytherapy 04: Commissioning and Implementation of a Cobalt-60 High Dose Rate Brachytherapy Source

    Energy Technology Data Exchange (ETDEWEB)

    Dysart, Jonathan [Horizon Health Network (Canada)

    2016-08-15

    An Eckert & Ziegler Bebig Co0.A86 cobalt 60 high dose rate (HDR) brachytherapy source was commissioned for clinical use. Long-lived Co-60 HDR sources offer potential logistical and economic advantages over Ir-192 sources, and should be considered for low to medium workload brachytherapy departments where modest increases in treatment times are not a factor. In optimized plans, the Co-60 source provides a similar dose distribution to Ir-192 despite the difference in radiation energy. By switching to Co-60, source exchange frequency can be reduced by a factor of 20, resulting in overall financial savings of more than 50% compared to Ir-192 sources. In addition, a reduction in Physicist QA workload of roughly 200 hours over the 5 year life of the Co-60 source is also expected. These benefits should be considered against the modest increases in average treatment time compared to those of Ir-192 sources, as well as the centre-specific needs for operating room shielding modification.

  9. Cobalt-60 total body irradiation dosimetry at 220 cm source-axis distance

    International Nuclear Information System (INIS)

    Glasgow, G.P.; Mill, W.B.

    1980-01-01

    Adults with acute leukemia are treated with cyclophosphamide and total body irradiation (TBI) followed by autologous marrow transplants. For TBI, patients seated in a stand angled 45 0 above the floor are treated for about 2 hours at 220 cm source-axis distance (SAD) with sequential right and left lateral 87 cm x 87 cm fields to a 900 rad mid-pelvic dose at about 8 rad/min using a 5000 Ci cobalt unit. Maximum (lateral) to minimum (mid-plane) dose ratios are: hips--1.15, shoulders--1.30, and head--1.05, which is shielded by a compensator filter. Organ doses are small intestine, liver and kidneys--1100 rad, lung--1100 to 1200 rad, and heart--1300 rad. Verification dosimetry reveals the prescribed dose is delivered to within +-5%. Details of the dosimetry of this treatment are presented

  10. Migration characteristics of cobalt-60 through sandy soil in high pH solution

    International Nuclear Information System (INIS)

    Ohnuki, Toshihiko

    1992-01-01

    Migration characteristics of 60 Co through sandy soil in high pH solution has been investigated by both column and batch techniques. The association of 60 Co with the sandy soil and its components were studied by sequential extraction techniques. The concentration profile of 60 Co in the sandy soil column was composed of two exponential curves showing that 60 Co would consist of immobile and mobile fractions. The immobile 60 Co was retained by the sandy soil and was distributed near the top. Though the mobile 60 Co was little sorbed by soil and migrated through the soil column, maximum concentration of 60 Co in the effluents decreased slightly with increasing path length of the soil column. The sequential extraction of 60 Co from the sandy soil and from its components showed that 60 Co was sorbed by both manganese oxide and clay minerals. And manganese oxide is one of the responsible soil components for the observed decrease in the maximum concentration of 60 Co in the effluents. Although the content of manganese oxide in the sandy soil was 0.13%, manganese oxide is the important component to prevent from the migration of 60 Co in the high pH solution. (author)

  11. Activation measurements for thermal neutrons. Part A. Cobalt (60Co) activation

    International Nuclear Information System (INIS)

    Kerr, George D.; Shizuma, Kiyoshi; Endo, Satoru; Maruyama, Takashi; Cullings, Harry M.; Komura, Kazuhisa; Okumura, Yutaka; Egbert, Stephen D.

    2005-01-01

    The 60 Co measurements at Hiroshima and Nagasaki were reviewed and compared with the results of the new DS02 calculations for the two cities. Some corrections were made to previously published data from the 1965 measurements of JNIRS, ground ranges of all of the 60 Co measurements were reviewed and new ground ranges were determined when possible by transforming sample coordinates to the new city maps for Hiroshima and Nagasaki, and transmission factors were investigated for a number of samples used in the 60 Co measurements. Transmission factors were not calculated for all samples used in the 60 Co measurements but some general rules were given for estimating transmission factors for these samples. Experimental measurements of the background 60 Co activity from environmental neutrons were also reviewed, and it was found that the 60 Co background from environmental neutrons was not an important factor in the 60 Co measurements of bomb-induced activity at either city. (J.P.N.)

  12. PENGARUH RADIASI SINAR GAMMA COBALT-60 TERHADAP SIFAT MORFOLOGI DAN AGRONOMI KETIGA VARIETAS JAGUNG (ZEA MAYS L.

    Directory of Open Access Journals (Sweden)

    Makhziah

    2017-04-01

    Full Text Available Mutation is one of the ways to improve genetic variation in plant breeding so the target traits were more easily obtained. Grains of three varieties of maize (Bisma, Madura local, and Gumarang were treated with gamma 60cobalt irradiation doses (0, 100, 200, and 300 Gy before sowing then planted in a split plot randomized block design with three replication, to be evaluated for their morphology and agronomic traits. The Main plot was cultivars and sub plot was gamma radiation rates. There was no interaction between gamma rates and cultivars of maize, but increasing of gamma rates caused decreasing of some traits. Some traits such as plant height and leaves number were decreased significantly when gamma rate increased 100 to 300 Gy as well yield components such as grain weight and grain number per ear. Gamma 200 caused produce more ears than other rates. Bisma exhibited greater performance than Madura and Gumarang both of morphology and agronomic traits.

  13. Comparative study of G2 delay and survival after /sup 241/Americium-. cap alpha. and /sup 60/Cobalt-. gamma. irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Luecke-Huhle, C.; Comper, W.; Hieber, L.; Pech, M.

    1982-06-01

    Survival and G2 delay following exposure to either /sup 60/Cobalt-..gamma..-rays or /sup 241/Americium-..cap alpha..-particles were studied in eight mammalian cell lines of human and animal origin including human fibroblasts from normal individuals and from patients with Ataxia telangiectasia or Fanconi's anemia. For both endpoints the effectiveness of alpha particle was greater as compared to ..gamma..-rays. RBE values for G2 delay (4.6-9.2) were in general comparable to RBE values derived from initial slopes of survival curves but higher compared to the ratio of mean inactivation doses. Ataxia cells were particularly sensitive to cell killing by ..gamma..-irradiation, however, showed average sensitivity to ..cap alpha..-particles of high LET. With the exception of Ataxia cells, cell killing and G2 delay seem to be related processes if individual cell cycle parameters are taken into account.

  14. Studi Standarisasi Radioterapi Cobalt-60 Terhadap Kuantitas Sel Darah Pada Penderita Kanker Serviks (Cancer Cervics Di Rsup Sanglah Denpasar

    Directory of Open Access Journals (Sweden)

    Retianingsih Oeta Ulan

    2017-09-01

    Full Text Available After doing research with Title Study of Cobalt-60 radiotherapy Standards Against Quantity Blood Cells In Patients with Cervical Cancer (Cancer Cervics at Sanglah Hospital in Denpasar. This study uses secondary data such as a complete blood from each patient with cervical cancer in 2015 that radiotherapy with fractionation method. The amount of patient data used in this study is 5 pieces. The quantity of blood cells that are analyzed include RBC, HGB, WBC and WBC Components (LY, EO, EO, BA, NE, MO. Fractionation dose is 800-5800cGy. The results of data analysis showed that each blood cell components are still within the range of 2-50%, so a method of radiotherapy is still fit for use.

  15. Effect of (/sup 60/cobalt) gamma rays on growth and root rot diseases in mungbean (vigna radiata L.)

    International Nuclear Information System (INIS)

    Ikram, N.; Dawar, S.; Zaki, M.J.; Abass, Z.

    2010-01-01

    Present investigation showed that gamma rays influences suppressive effect on root rot fungi such as Macrophomina phaseolina (Tassi) Goid, Rhizoctonia solani Kuhn and Fusarium spp., and inducive effect on growth parameters of mung bean (Vigna radiata L.). Seeds of mung bean were treated with gamma rays (/sup 60/Cobalt) at time periods of 0 and 4 minutes and stored for 90 days at room temperature to determine its effect on growth parameters and infection of root infecting fungi. All treatments of gamma rays enhanced the growth parameters as compared to untreated plants. Infection of M. phaseolina, R. solani and Fusarium spp., were significantly decreased on mung bean seeds treated with gamma rays. Gamma rays significantly increased the growth parameters and controlled the root rot fungi up to 90 days of storage of seeds. (author)

  16. Study of ozone gas formed in the industrial radiation process with cobalt-60 and its impact on the environment

    International Nuclear Information System (INIS)

    Uzueli, Daniel Henrique

    2013-01-01

    The radiation processing is present in various products such as foods, medical disposable, electrical cables, gems, among others. This process aims to improve the properties, sterilize or sanitize irradiated products. In industrial irradiators facilities, electromagnetic radiation (gamma and X-rays) or electrons before they interact with the products in processing, there are a layer of air. To interact with this air layer, it causes radiolytic effects on the molecules present in the ambient atmosphere, and the main interaction are with the oxygen molecules that have their bonds broken, separating them into two highly reactive atoms that recombine with the other molecule of oxygen to form ozone gas. In this work it was studied the formation, decay and dispersion of ozone in industrial gamma irradiators facilities that use cobalt-60 as a source of radiation. The monitoring of ozone concentration was performed by optical absorption method in a commercial monitor. (author)

  17. Sterilization of silver acidium pipemedicum skin for the treatment of burns by radioactive cobalt-60-γray

    International Nuclear Information System (INIS)

    Zeng Defeng; Cao Fengsheng; Chen Qinglong; Li Guohui; Su Ziyi; Cao Yong; Wu Wenqing; Qiu Zeyi; Chen Zhanxian

    1995-01-01

    The radiated silver acidum pipemedicum skin (RSAPS) was made of 0.4-0.8mm laminal skin from healthy white pig, which was infiltrated in norfloxacin and silver nitrate, packed with the filkm bag of alummium poil and radiated by cobalt-60γ-ray for sterilization at the dosage of 27.92-35.31Gy/min for a total dose of 25KGY, RSAPS was very effective in sterilization and had no bad effect on elasticity, adhesion, water permeability, and structure of pig skin. So it is highly appreciated by the patients and medical personnel for its convenience of usage and has gained good social and economic beneficial results. (Author)

  18. Hematological changes in sheep inoculated with natural and Cobalt60-irradiated Crotalus durissus terrificus venom (Laurenti, 1768)

    International Nuclear Information System (INIS)

    Netto, D.P.; Alfieri, A.A.; Balarim, M.R.S.; Chiacchio, S.B.; Bicudo, P.L.; Nascimento, N.

    2004-01-01

    Natural (NV) and Cobalt 60 -irradiated (IrV) Crotalus durissus terrificus venom were used to evaluate serum production capacity of sheep and possible hematological and biochemical effects. Freeze-dried venom aliquots were diluted in acidified saline solution (NaCl 150 m M, p H 3.0) and irradiated by a Cobalt 60 source at a dose of 5.54 x 102 Gy/h and a concentration of 2.000 Gy. Twelve sheep were divided into two groups of six animals. One group received irradiated venom (IrV) and the other natural venom (NV). Three antigen doses (venom) were administered at monthly intervals. Blood samples were collected weekly for analysis of serum neutralization potency and capacity, complete blood count, total plasma protein, fibrinogen, albumin, and globulin. At the end of the experiment, the animals were challenged with a LD 50 for sheep and showed no signs of envenoming. The two groups did not present clinical alterations. Results of the total leukocyte count did not present interaction or time factor effect for both groups, but there was a different action between them, with the NV group presenting more cells than the IrV group. The leukocyte increase to 13,000/μl indicates that slight leucocytosis occurred in the week after the first inoculation in the NV group. There was no statistically significant difference between groups in the absolute count of segmented neutrophils, eosinophils, and lymphocytes but there were statistically significant oscillations in values at the different collecting times. The NV group presented an increase in the absolute neutrophil count after the first inoculation that persisted for 5 weeks. In the IrV group, the increase in neutrophils occurred only in the first week returning to normal in the following weeks. The alterations in the neutrophil count are indicative of systemic inflammatory response related to cytokine release; response was more marked in the N V group, showing its greater toxicity. (author)

  19. Dosimetric intercomparison in Cobalt 60 unities using TLD-100 crystals and CaSO{sub 4}: Dy + Ptfe; Intercomparacion dosimetrica en unidades de cobalto 60 usando cristales de TLD-100 y CaSO{sub 4}: Dy + PTFE

    Energy Technology Data Exchange (ETDEWEB)

    Gaona, E. [Universidad Autonoma Metropolitana Xochimilco, Mexico D.F. (Mexico); Azorin N, J. [Universidad Autonoma Metropolitana Iztapalapa, Mexico D.F. (Mexico); Perez P, M.A. [Instituto Nacional de Cancerologia, Mexico D.F. (Mexico); Castillo H, M. [Centro Medico Nacional 20 de Noviembre, ISSSTE, Mexico D.F. (Mexico); Flores F, F. [Unidad de Oncologia, Centro Medico Nacional, IMSS, Mexico D.F. (Mexico); Guzman R, L.V. [Unidad de Oncologia, Hospital General de Mexico, Mexico D.F. (Mexico)

    1999-07-01

    The purpose of this work is to design and construct a phantom in basis of thermoplastic polymer of methyl methacrylate that is reutilizable and which allows to do an analysis of the absorbed doses in thermoluminescent crystals (Tl) exposed to cobalt 60 to establish the dosimetric intercomparison in cobalt units which allows to do the follow-up of the Quality assurance programs, standardization of calibration procedures, dosimetry and TLD post intercomparison in radiotherapy. This work allows also prove new thermoluminescent materials of national manufacture developed by Juan Azorin and collaborators as the CaSO{sub 4}: Dy + Ptfe. This is a first study which is realized in Mexico with the system crystal-phantom for aims to intercomparison in cobalt 60 units. In this work participate eight unities of cobalt 60 of different trades belonging at four radiotherapy centers. The results of the dose intercomparison of the eight unities of cobalt 60 were in the range 0.95-1.13, taking in account that the values between 0.95 and 1.05 were considered acceptable in terms of the requirements by the standing legislation. (Author)

  20. Design of inspection equipment vehicle of mobile cobalt-60 container scanner

    International Nuclear Information System (INIS)

    Zhang Yanmin; An Jigang; Zhou Liye; Liu Yisi; Wu Zhifang; Xiang Xincheng; Huang Songling

    2000-01-01

    The author introduced the design principle of Inspection Equipment Vehicle of TCM-SCAN Mobile 60 Co container inspection system. Three schemes had been compared. The scheme of scan gate in form of pucker-able rails standing on the vehicle was determined. Prototype was prepared in September 1999. Mobile 60 Co container inspection system had the same inspection performance of fixed 60 Co container inspection system

  1. Quality and security on the uses of cobalt 60 sources for industrial irradiators

    International Nuclear Information System (INIS)

    Desroches, J.

    1976-01-01

    The construction and operation of industrial irradiators using large quantities of 60 Co give rise to an important problem of security. The CEA Radioisotope Department which manufactures and sells sources of 60 Co has created an insurance quality system which insures the maximum of security for the user. (orig.) [de

  2. Quality and security on the uses of cobalt 60 sources for industrial irradiators

    International Nuclear Information System (INIS)

    Desroches, J.

    1976-01-01

    The construction and operation of industrial irradiators using large quantities of 60 Co give rise to an important problem of security. The CEA Radioisotope Department which manufactures and sells sources of 60 Co has created an insurance Quality System which insures the maximum of security for the user

  3. Comparison of 60Cobalt and 192Iridium sources in high dose rate afterloading brachytherapy

    International Nuclear Information System (INIS)

    Richter, J.; Baier, K.; Flentje, M.

    2008-01-01

    Purpose: 60 Co sources with dimensions identical to those of 192 Ir have recently been made available in clinical brachytherapy. A longer half time reduces demands on logistics and quality assurance and perhaps costs. Material and Methods: Comparison of the physical properties of 60 Co and 192 Ir with regard to brachytherapy. Results: Required activities for the same air kerma rate are lower by a factor of 2.8 for 60 Co. Differential absorption in tissues of different densities can be neglected. Monte Carlo calculations demonstrate that integral dose due to radial dose fall off is higher for 192 Ir in comparison to 60 Co within the first 22 cm from the source (normalization at 1 cm). At larger distances this relationship is reversed. Conclusion: Clinical examples for intracavitary and interstitial applications however, show practically identical dose distributions in the treatment volume. (orig.)

  4. Recent status on cobalt-60 gamma ray radiation sources production and its application in China

    International Nuclear Information System (INIS)

    Cao Zhijian; Song Yunjiang; Zhang Chunhua; Li Maoling

    1993-01-01

    This paper describes the status of Co-60 γ ray radiation sources and their application in China. At present, the production capacity of Co-60 γ ray radiation sources in China is about 11.1 PBq (0.3 MCi) per year. 5 years later, it is increased to 37 PBq (1 MCi) per year. The radioactivity of each source is 370 TBq - 740 TBq (1000-2000 Ci). There are over 150 Co-60 γ ray radiation facilities with total design capacity of over 370 PBq (10 MCi) and practical capacity of about 92.5 PBq (2.5 MCi) in operation. The number of Co-60 γ ray radiation facilities with practical capacity of over 3.7 PBq (0.1 MCi) is 14. The main applications of the Co-60 γ ray sources are radiation crosslinking, radiation sterilization of disposable medical supplies and food irradiation. The prospects for Co-60 γ ray radiation source application in China are good. (author)

  5. Effect of cobalt 60 gamma-ray irradiation on the hatching process of chicken eggs

    International Nuclear Information System (INIS)

    Ohkuma, Yoshikazu

    1981-01-01

    An experiment on fertilized chicken eggs was carried out to determine the effects of 60 Co irradiation on the embryos, their fatality, and growth impairment or deformity, in particular. The experimental groups, consisting of 10 eggs each, recieved a 60 Co irradiation of 50 to 2,000 rads on any one day between day 0 and day 20 of incubation. The larger the irradiation dose, the greater was the number of dead embryos. The fatality was higher in the groups receiving irradiation in the earlier stage (1st week). The resultant death was a chronic one. The irradiation also caused body weight decrease and growth impairment. A decrease in the brain and liver weights was noted, suggesting insufficiency in these organs. Deformity occurred in 4%, most of which involved impairments of skeletal growth, of the bones of the extremities and the bill, in particular. Administration of the SH amino acid, cysteine tended to alleviate the adverse effects of the 60 Co irradiation. These results for fertilized chicken eggs suggest the possibility of abortion and the occurrence of deformities in human fetuses if they should be subjected to 60 Co irradiation. (author)

  6. An evaluation of low-energy x-ray and cobalt-60 irradiations of MOS transistors

    International Nuclear Information System (INIS)

    Dozier, C.M.; Fleetwood, D.M.

    1987-01-01

    An evaluation of methodologies for irradiating MOS transistors with low-energy x-ray and Co-60 sources has been performed. The authors find that comparisons of voltage shifts produced by bulk trapped charge and interface states in MOS transistors irradiated using two different low energy x-ray sources (an ARACOR 10 keV W source and an 8 keV Cu source) agree to within better than 30 percent. This quality of agreement is similar in magnitude to that between MOS devices irradiated by different Co-60 sources. In contrast, the measurements indicate that interlaboratory comparisons of ratios of shifts produced by x-ray and Co-60 sources can lead to differences in ratios as large as a factor of --1.7. Improved electron-hole recombination data for oxides is presented. This recombination correction, in conjunction with a correction for interface dose enhancement, is used to predict the ratios of shifts produced by x-ray and Co-60 sources. However, the results show that corrections for electron-hole recombination and interface does enhancement do not, by themselves, adequately predict the field dependent behavior of these transistors

  7. Determination of C0-60 in Cobalt Slugs and Slabs and Radionuclides in Curium Sampler Slugs L-Reactor Disassembly Basin

    International Nuclear Information System (INIS)

    Casella, V.R.

    2004-01-01

    Co-60 was historically produced in the SRS reactors. Cobalt slugs were irradiated in the early 1970s. Post-production, remaining cobalt slugs (including slab form) were consolidated for storage. There are approximately nine hundred cobalt slugs currently stored awaiting final disposition. These slugs had historically incomplete documentation for activity rates; therefore, assaying was required in order to determine their activity levels. Since the gamma dose rate from these slugs is extremely high, the most cost effective way to shield a source of this magnitude from personnel and the radiation detector was to use the basin water in which the slugs are stored as the shield. A sodium iodide gamma detector was placed above a specially designed air collimator assembly, so that slug was at least eight feet from the detector and was shielded by the basin water. Using a sodium iodide detector and multichannel analyzer system and an underwater collimator assembly, Co-60 concentrations we re determined for Disassembly Basin cobalt slugs and slabs and 18 curium sampler slugs. The total activity of all of the assayed slugs summed to 31,783 curies. From the Co-60 concentrations of the curium sampler slugs, the irradiation flux was determined for the known irradiation time. The amounts of Pu-238, 239, 240, 241, 242; Am-241, 243; and Cm-242, 244 produced were then obtained based on the original amount of Pu-239 irradiated

  8. Re-Shielding of Cobalt-60 Teletherapy Rooms for Tomotherapy and Conventional Linear Accelerators using Monte Carlo Simulations

    Science.gov (United States)

    Çeçen, Yiğit; Yazgan, Çağrı

    2017-09-01

    Purpose. Nearly all Cobalt-60 teletherapy machines were removed around the world during the last two decades. The remaining ones are being used for experimental purposes. However, the rooms of these teletherapy machines are valuable because of lack of space in radiotherapy clinics. In order to place a new technology treatment machine in one of these rooms, one should re-shield the room since it was designed only for 1.25 MeV gamma beams on average. Mostly, the vendor of the new machine constructs the new shielding of the room using their experience. However, every radiotherapy room has different surrounding work areas and it would be wise to shield the room considering these special conditions. Also, the shield design goal of the clinic may be much lower than the International Atomic Energy Agency (IAEA) or the local association accepts. The study shows re-shielding of a Cobalt-60 room, specific to the clinic, using Monte Carlo simulations. Materials & Methods: First, a 6 MV Tomotherapy machine, then a 10 MV conventional linear accelerator (LINAC) was placed inside the Cobalt-60 teletherapy room. The photon flux outside the room was simulated using Monte Carlo N-Particle (MCNP6.1) code before and after re-shielding. For the Tomotherapy simulation, flux distributions around the machine were obtained from the vendor and implemented as the source of the model. The LINAC model was more generic with the 10 MeV electron source, the tungsten target, first and secondary collimators. The aim of the model was to obtain the maximum (40x40 cm2) open field at the isocenter. Two different simulations were carried out for gantry angles 90o and 270o. The LINAC was placed in the room such that the primary walls were A' (Gantry 270o) and C' (Gantry 90o) (figure 1). The second part of the study was to model the re-shielding of the room for Tomotherapy and for the conventional LINAC, separately. The aim was to investigate the recommended shielding by the vendors. Left side of the room

  9. Accounting for the self-absorption of betas in cobalt-60 hot particles

    International Nuclear Information System (INIS)

    Lantz, M.W.; Steward, J.B.

    1988-01-01

    This paper reports that the assumptions used dose calculations can be overly conservative for discrete hot particles (activated satellite chips and irradiated fuel fragments) due to self-absorption of betas within the particles. Using data from tests with a Co-60 hot particle, a model is developed to estimate the dose reduction factor afforded by self-absorption in a satellite chip with a known thickness. The model can be applied indirectly using ion chamber survey instrument readings (the thickness of the particle does not have to be measured). Tests with Co-60 particles found at the Palo Verde Nuclear Generating Station verify that self-absorption is significant -- in one case, a dose reduction factor of 7 was measured in a satellite chip with a visible thickness

  10. Sedimentation of Cobalt-60 and Cesium-137 in the bay of Tvaeren 1964-1980

    International Nuclear Information System (INIS)

    Ramberg, L.; Lampe, S.

    1980-11-01

    Since 1964 the Co-60 and Cs-137 radioactivity of the sediments of the Tvaeren bay has been recorded every year at several points. Changes have been analysed in relation to atmospheric fallout releases from Studsvik distance from release point and depth. Estimates of total quantity for both nuclides bound up in the sediments and a forecast of future trends are presented. Sedimentation coefficients have been calculated and the factors which govern the degree of sedimentation are discussed.(G.B.)

  11. Hematological changes in sheep inoculated with natural and Cobalt{sub 60}-irradiated Crotalus durissus terrificus venom (Laurenti, 1768)

    Energy Technology Data Exchange (ETDEWEB)

    Netto, D.P.; Alfieri, A.A.; Balarim, M.R.S. [Universidade Estadual de Londrina, PR (Brazil). Faculdade de Medicina Veterinaria e Zootecnia. Dept. de Medicina Veterinaria Preventiva]. E-mail: rnetto@uel.br; Chiacchio, S.B.; Bicudo, P.L. [UNESP, Botucatu, SP (Brazil). Faculdade de Medicina Veterinaria e Zootecnia; Nascimento, N. [Instituto de Pesquisas Energeticas e Nucleares (IPEN), Sao Paulo, SP (Brazil). Supervisao de Radiobiologia

    2004-07-01

    Natural (NV) and Cobalt{sub 60}-irradiated (IrV) Crotalus durissus terrificus venom were used to evaluate serum production capacity of sheep and possible hematological and biochemical effects. Freeze-dried venom aliquots were diluted in acidified saline solution (NaCl 150 m M, p H 3.0) and irradiated by a Cobalt 60 source at a dose of 5.54 x 102 Gy/h and a concentration of 2.000 Gy. Twelve sheep were divided into two groups of six animals. One group received irradiated venom (IrV) and the other natural venom (NV). Three antigen doses (venom) were administered at monthly intervals. Blood samples were collected weekly for analysis of serum neutralization potency and capacity, complete blood count, total plasma protein, fibrinogen, albumin, and globulin. At the end of the experiment, the animals were challenged with a LD{sub 50} for sheep and showed no signs of envenoming. The two groups did not present clinical alterations. Results of the total leukocyte count did not present interaction or time factor effect for both groups, but there was a different action between them, with the NV group presenting more cells than the IrV group. The leukocyte increase to 13,000/{mu}l indicates that slight leucocytosis occurred in the week after the first inoculation in the NV group. There was no statistically significant difference between groups in the absolute count of segmented neutrophils, eosinophils, and lymphocytes but there were statistically significant oscillations in values at the different collecting times. The NV group presented an increase in the absolute neutrophil count after the first inoculation that persisted for 5 weeks. In the IrV group, the increase in neutrophils occurred only in the first week returning to normal in the following weeks. The alterations in the neutrophil count are indicative of systemic inflammatory response related to cytokine release; response was more marked in the N V group, showing its greater toxicity. (author)

  12. Developed and applications of a method for dose comparation of the cobalt 60 in radiotherapy

    International Nuclear Information System (INIS)

    Leao, J.L.B.

    1975-01-01

    IAEA and WHO developed a postal intercomparison program for measuring the output of Co-60 therapy units all over the world. This work reports first results of an modified postal intercomparison based on IAEA/WHO program. A mailable 10 x 10 x 10,5cm Mix-D phantom with embedded TLD dosimeters, films and field markers of lead and a questionary were developed to obtain not only informations regarding output of Co-60 therapy machines but also to get information about alignment, field homogeneity, dose calculations, field size and surface dose. This program was field tested in 10 different Radiotherapy Centers. The results of this intercomparison gave a spread of the absorbed dose from 78 rads to 127 rads for the 100 rads asked for in 5cm depth of the phantom. Variation in the prescribed fieldsize of 6 x 6cm were between 30cm 2 and 100cm 2 . In half of the cases inhomogeneity of the radiation field was spotted [pt

  13. Repacking of Cobalt 60 spent sources in the central interim storage

    International Nuclear Information System (INIS)

    Zeleznik, N.

    2003-01-01

    After the transfer of the responsibility for the management of the Central interim storage for waste from small producers, located at the reactor centre in Brinje near Ljubljana, Slovenia, the national Agency for radwaste management (ARAO) started with most urgent activities to improve the utilization of the storage facility. One of the main tasks has also been the rearrangement of the already stored radioactive waste in order to reduce volume of the waste and to collect same radioisotopes in the containers. The latest campaign, performed in 2002/2003, was repacking of all Co-60 spent sealed sources in the storage facility and also at the producer's premises which were after conditioning put into two drums with concrete matrix and stored back to the Central interim storage. The preparation works together with the implementation are described in the paper. (author)

  14. Skin response to cobalt 60 irradiation and the consequences for matching the color of facial prostheses

    International Nuclear Information System (INIS)

    van Oort, R.P.; Vermey, J.; Ten Bosch, J.J.

    1984-01-01

    A radiotherapy treatment ( 60 Co) of cancer in the head and neck region causes side effects in the skin that postpone the facial prosthetic treatment. The increasing and fading erythema and pigmentation of the skin was investigated with the use of a subtractive colorimeter. This method was verified with photographs scored according to the Oxford scoring system. Fourteen patients were investigated during a period of 24 weeks. The mean colorimetric skin response showed a peak 6 weeks after the onset of irradiation. Six to 7 weeks later, there was no significant difference between the skin color before and after irradiation. At this time the dry desquamation of the skin is healed. From this viewpoint, the color matching procedure for a facial prosthesis may start not earlier than 15 weeks from the onset of irradiation. If a nonirradiated control field in the facial region is present, a color match for the facial prosthesis can be started just after the irradiation period

  15. Sterilization by cobalt 60 of the mediterranean fruit fly Ceratitis Capitate Wied

    International Nuclear Information System (INIS)

    Dimundu Puena, I.; Cirio, Ugo.

    1978-01-01

    Ceratitis capitata have been irradiated with 2, 4, 6 and 10 Krad of a Co-60 gamma irradiator at 300 rad/min flow. Following results have been obtained: abundant and regular egg laid at 1 to 2 krads, reduced but regular egg laid at 4 krads and total sterility from 6 krads. The 10 krads irradiated insects exhibit satisfactory life time and activity. The 6 and above krads irradiated females are completely sterile but have the laid reflex. The 8 krads irradiated males exhibit sexual strength comparable to that of normal males. Males fertility is decreased with increasing irradiation dose, eggs obtained with normal female have fertility of less than 1 % for doses above 7 krads. However it appears that at 8 krads dose, some males can form again normal spermatozoids after 20 to 30 days. The recommended irradiation dose is 10 krads

  16. Sensory evaluation of black beans submitted to gamma radiation from Cobalt-60

    International Nuclear Information System (INIS)

    Moura, Neila Camargo de; Canniatti-Brazaca, Solange Guidolin; Spoto, Marta Helena Fillet; Arthur, Valter

    2005-01-01

    The objective of this research was to evaluate the sensory aspects of black beans submitted to gamma radiation from 60 Co. The study involved eight panelists, between 17 to 23 years old, who were selected and trained for the descriptive analysis of appearance, aroma, flavor and texture. The panelists analyzed alterations of appearance, aroma, flavor and texture of non-irradiated and irradiated black beans with doses 2, 4, 6, 8 and 10kGy. The results were analyzed by test F, ANOVA and the Tukey test (5%), with the use of computers and the sensory analysis software Compusense Five and SAS. The results showed that irradiated samples decreased the bitter flavor, accentuated color and brightness and samples non-irradiated dry texture. The radiation treatment is a good method for conservation of black beans in doses evaluated in this study.(author)

  17. Studied by electron paramagnetic resonance (EPR) of polymethyl methacrylate (PMMA) irradiated with gamma photons from cobalt 60

    International Nuclear Information System (INIS)

    Jalali, Hajer

    2013-01-01

    Ionizing radiation is radiation able to deposit enough energy in the material through which they pass to create ionization. These ionizing radiations, when mastered, have many practical uses beneficial (areas of health, industry ...). Gamma rays are emitted by radioactive nuclei. The objective of our work is the study of polymethyl methacrylate (PMMA) irradiated by gamma photons from cobalt-60. To study the technique of radio spectroscopy (9 to 10Hz) electron paramagnetic resonance EPR is used. This technique is specific to characterize transient free radicals involved in chemical reactions such as oxidation, combustion, polymerization reactions ... We analyzed the EPR spectra three batch KS, EB, and JF our dosimeter according to the dose (high and low) and showed that the dosimetric response can be represented in exponential form (high dose) and linear form (low dose). We also studied the kinetics of decay of the EPR signal as a function of time (fading) and showed that the responses relating to stabilize after 20 min of irradiation.

  18. Lethal dose determination of Cobalt-60 for adult Tribolium castaneum (Coleoptera: Tenebrionidae) and Cryptolestes ferrugineus (Coleoptera: Laemophloeidae)

    International Nuclear Information System (INIS)

    Farias, Anderson Aparecido; Potenza, Marcos Roberto; Reis, Fabricio Caldeira; Sato, Mario Eidi

    2015-01-01

    The insect infestation is a major problem in the grain storage. The pesticides are most widely used method for disinfestation and prevention. Treatment with gamma irradiation may increase the product shelf life without encountering formation of waste can be used in packaged foods and ready for commercialization, representing an important alternative to the use of pesticides. This study aimed to determine the immediate lethal dose of gamma radiation for adults of Tribolium castaneum and Cryptolestes ferrugineus. The study was conducted in the Instituto Biologico and the radiations held at the Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN, Sao Paulo city, using a multipurpose irradiator Cobalt-60 with 3.31 dose rate and 3.23 kGy in months of November/2014 and January/2015. Each experimental unit consisted of 20 adult insects, confined in a 10 mL polyethylene container. The experimental plots in number 10 per dose were subjected to increasing doses of gamma radiation: 0; 0.5; 0.75; 1.0; 1.25; 1.50; 1.75; 2.00; 2:50 and 3.00 kGy. Mortality was assessed within two to four hours after irradiation. The data were submitted to Probit analysis, using the POLO PLUS program. The LD90 to control 90% (LD90) to control adult Cryptolestes ferrugineus and Tribolium castaneum were 2.73 and 2.91 kGy, respectively. (author)

  19. Lethal dose determination of Cobalt-60 for adult Tribolium castaneum (Coleoptera: Tenebrionidae) and Cryptolestes ferrugineus (Coleoptera: Laemophloeidae)

    Energy Technology Data Exchange (ETDEWEB)

    Farias, Anderson Aparecido, E-mail: potenza@biologico.sp.gov.br [Instituto Biologico, Centro de Pesquisa e Desenvolvimento de Protecao Ambiental, Sao Paulo, SP (Brazil); Potenza, Marcos Roberto, E-mail: fcreis@usp.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil); Reis, Fabricio Caldeira; Sato, Mario Eidi, E-mail: mesato@biologico.sp.gov.br [Instituto Biologico, Centro Experimental Central, Laboratorio de Acarologia, Campinas, SP (Brazil)

    2015-07-01

    The insect infestation is a major problem in the grain storage. The pesticides are most widely used method for disinfestation and prevention. Treatment with gamma irradiation may increase the product shelf life without encountering formation of waste can be used in packaged foods and ready for commercialization, representing an important alternative to the use of pesticides. This study aimed to determine the immediate lethal dose of gamma radiation for adults of Tribolium castaneum and Cryptolestes ferrugineus. The study was conducted in the Instituto Biologico and the radiations held at the Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN, Sao Paulo city, using a multipurpose irradiator Cobalt-60 with 3.31 dose rate and 3.23 kGy in months of November/2014 and January/2015. Each experimental unit consisted of 20 adult insects, confined in a 10 mL polyethylene container. The experimental plots in number 10 per dose were subjected to increasing doses of gamma radiation: 0; 0.5; 0.75; 1.0; 1.25; 1.50; 1.75; 2.00; 2:50 and 3.00 kGy. Mortality was assessed within two to four hours after irradiation. The data were submitted to Probit analysis, using the POLO PLUS program. The LD90 to control 90% (LD90) to control adult Cryptolestes ferrugineus and Tribolium castaneum were 2.73 and 2.91 kGy, respectively. (author)

  20. Design and Simulation of 5-DOF Vision-Based Manipulator to Increase Radiation Safety for Industrial Cobalt-60 Irradiators

    International Nuclear Information System (INIS)

    Solyman, A.E.; Keshk, A.B.; Sharshar, K.A.; Roman, M.R.

    2016-01-01

    Robotics has proved its efficiency in nuclear and radiation fields. Computer vision is one of the advanced approaches used to enhance robotic efficiency. The current work investigates the possibility of using a vision-based controlled arm robot to collect the fallen hot Cobalt-60 capsules inside wet storage pool of industrial irradiator. A 5-DOF arm robot is designed and vision algorithms are established to pick the fallen capsules on the bottom surface of the storage pool, read the information printed on its edge (cap) and move it to a safe storage place. Two object detection approaches are studied; RGB-based filter and background subtraction technique. Vision algorithms and camera calibration are done using MATLAB/SIMULINK program. Robot arm forward and inverse kinematics are developed and programmed using an embedded micro controller system. Experiments show the validity of the proposed system and prove its success. The collecting process will be done without interference of operators, hence radiation safety will be increased.

  1. External cobalt 60 irradiation alone for stage IIB carcinoma of the uterine cervix

    International Nuclear Information System (INIS)

    Lei, Z.Z.; He, F.Z.

    1989-01-01

    From 1964 to 1980, 97 patients with Stage IIb carcinoma of cervix uteri were treated by external 60Co irradiation alone. Of these 97 patients, 94 (96.9%) had squamous cell carcinoma. The parametrial extension of the lesion almost reached the pelvic wall in 73.2% and vaginal extension reached to the upper half of vaginal in 24.7% of the patients. A tumor dose of 60 Gy was given to the whole pelvis by a four field technic (opposing parallel AP and lateral portals) in 6-8 weeks. A booster dose of 10 Gy was delivered to the cervix by a pair of reduced opposing parallel AP portals or a perineal portal in a week. The doses delivered were equivalent to the Time-Dose-Fractionation (TDF) value of 110-130 at the center of pelvis and 90-110 in the whole pelvis. The 5-year survival rate for all 97 patients was 56.7%. It was 59.8% when those who died of other diseases were excluded. The prognosis of patients without residual tumor on the cervix and/or vagina was better than that with residual tumor (p less than 0.01). Thirty-seven patients died of cancer (23 died of recurrence, 8 of distant metastases, 2 of both, and 4 were lost before the fifth year). Of these 37 patients, 97.3% died within 3 years after initial treatment. During the radiation treatment, reactions were moderate. Late complications included 19 (19.6%) with mild cystitis and 16 (16.5%) with mild proctitis, 2 (2.7%) developed recto-vaginal fistula. These results were slightly poorer than those using intracavitary and external irradiation or the combination of preoperative irradiation plus surgery. Yet, for patients with extensions nearing the pelvic wall or with contra-indications to surgery or intracavitary radiotherapy, external irradiation alone is still of value

  2. Hematological changes in sheep inoculated with natural and Cobalt60-irradiated Crotalus durissus terrificus venom (Laurenti, 1768

    Directory of Open Access Journals (Sweden)

    D. P. Netto

    2004-01-01

    Full Text Available Natural (NV and Cobalto60-irradiated (IrV Crotalus durissus terrificus venom were used to evaluate serum production capacity of sheep and possible hematological and biochemical effects. Freeze-dried venom aliquots were diluted in acidified saline solution (NaCl 150 mM, pH 3.0 and irradiated by a Cobalt 60 source at a dose of 5.54 x 102 Gy/h and a concentration of 2.000 Gy. Twelve sheep were divided into two groups of six animals. One group received irradiated venom (IrV and the other natural venom (NV. Three antigen doses (venom were administered at monthly intervals. Blood samples were collected weekly for analysis of serum neutralization potency and capacity, complete blood count (CBC, total plasma protein, fibrinogen, albumin, and globulin. At the end of the experiment, the animals were challenged with a LD50 for sheep and showed no signs of envenoming. The two groups did not present clinical alterations. Results of the total leukocyte count did not present interaction or time factor effect for both groups, but there was a different action between them, with the NV group presenting more cells than the IrV group. The leukocyte increase to 13,000/ml indicates that slight leukocytosis occurred in the week after the first inoculation in the NV group. There was no statistically significant difference between groups in the absolute count of segmented neutrophils, eosinophils, and lymphocytes but there were statistically significant oscillations in values at the different collecting times. The NV group presented an increase in the absolute neutrophil count after the first inoculation that persisted for 5 weeks. In the IrV group, the increase in neutrophils occurred only in the first week returning to normal in the following weeks. The alterations in the neutrophil count are indicative of systemic inflammatory response related to cytokine release; response was more marked in the NV group, showing its greater toxicity.

  3. Effects of 60 Cobalt ionizing radiation in morphology and metabolism of yeasts and Chlamydospore of Candida albicans

    International Nuclear Information System (INIS)

    Grillo, Michel R.F.; Demicheli, Marina C.; Andrade Junior, Heitor F.; Galiesteo Junior, Andres A.J.

    2015-01-01

    Candida albicans is a fungus responsible for 80-90% of fungal infections, as the symptoms are similar to those of systemic bacterial infections there is a difficulty for immediate diagnosis. These difficulties can lead to delays of antifungal therapy, which contributes to the high mortality rates associated with this infection. Resistance structures referred to as chlamydospores are very common in the pathogen, representing different cell types that form in response to certain genetic or environmental conditions. Recently, various antifungal agents and new therapeutic strategies have come into use, allowing the fungus to acquire a resistance to the drugs. The use of ionizing radiation has been widely employed for the production of immunogens against various parasites. In this work, we evaluate the effects of gamma radiation ( 60 Co) in yeast and chlamydospore of C. albicans with doses ranging from 320 to 10.240 Gy with Cobalt 60. Subsequently the samples were plated and after seven days, the colony forming units (CFU) told. The viability of irradiated cells were evaluated using the Janus green dye. A dose of 6000 Gy was considered ideal for the mitigation of chlamydospore and yeast. The dimorphic change mechanisms of both fungal structures were not harmed. The viability of chlamydospores remained above 70% while the yeast viability remained above 85%. By transmission electron microscopy and fluorescence microscopy may be noted cytoplasmic changes, defects in the cell wall, mitochondria, and the presence of partially preserved vesicles of both morphological forms of C. albicans. Irradiation both chlamydospore as C. albicans yeast allows the suppression of their reproduction, opening the possibility of their use in future candidate immunogens. (author)

  4. Effects of 60 Cobalt ionizing radiation in morphology and metabolism of yeasts and Chlamydospore of Candida albicans

    Energy Technology Data Exchange (ETDEWEB)

    Grillo, Michel R.F.; Demicheli, Marina C.; Andrade Junior, Heitor F.; Galiesteo Junior, Andres A.J., E-mail: galisteo@usp.br [Universidade de Sao Paulo (IMTSP/USP), Sao Paulo, SP (Brazil). Instituto de Medicina Tropical. Lab. de Protozoologia; Takakura, Cleusa F.H. [Universidade de Sao Paulo (FM/USP), Sao Paulo, SP (Brazil). Departamento de Patologia de Molestias Transmissiveis. Lab. de Patologia; Negro, Gilda M.B. del [Universidade de Sao Paulo (HCFM/USP/IMTSP/LIM-53), Sao Paulo, SP (Brazil). Hospital das Clinicas. Lab. de Micologia; Nascimento, Nanci do [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2015-07-01

    Candida albicans is a fungus responsible for 80-90% of fungal infections, as the symptoms are similar to those of systemic bacterial infections there is a difficulty for immediate diagnosis. These difficulties can lead to delays of antifungal therapy, which contributes to the high mortality rates associated with this infection. Resistance structures referred to as chlamydospores are very common in the pathogen, representing different cell types that form in response to certain genetic or environmental conditions. Recently, various antifungal agents and new therapeutic strategies have come into use, allowing the fungus to acquire a resistance to the drugs. The use of ionizing radiation has been widely employed for the production of immunogens against various parasites. In this work, we evaluate the effects of gamma radiation ({sup 60}Co) in yeast and chlamydospore of C. albicans with doses ranging from 320 to 10.240 Gy with Cobalt 60. Subsequently the samples were plated and after seven days, the colony forming units (CFU) told. The viability of irradiated cells were evaluated using the Janus green dye. A dose of 6000 Gy was considered ideal for the mitigation of chlamydospore and yeast. The dimorphic change mechanisms of both fungal structures were not harmed. The viability of chlamydospores remained above 70% while the yeast viability remained above 85%. By transmission electron microscopy and fluorescence microscopy may be noted cytoplasmic changes, defects in the cell wall, mitochondria, and the presence of partially preserved vesicles of both morphological forms of C. albicans. Irradiation both chlamydospore as C. albicans yeast allows the suppression of their reproduction, opening the possibility of their use in future candidate immunogens. (author)

  5. Effects of gamma radiation of Cobalt-60 on arabica and conillon seeds coffea: physic-chemistry evaluation

    International Nuclear Information System (INIS)

    Silva, Marcus Henriques da

    2012-01-01

    Brazil is the largest producer and exporter of coffee in the world. The coffee bean is one of the main products of the Brazilian trade balance. Two species of coffee are the most economically important: the Coffea arabica L. and Coffea canephora Pierre is the largest representative of the Coffea canephora Pierre is the coffea conillon. Food irradiation is an area of research that aims to increase the shelf life of foods and controlling pests. This study aimed to verify the physicochemical variables of Arabica coffee and conillon were affected when exposed to doses of gamma radiation from cobalt-60. The samples were provided by Polo in Coffee Quality Technology, Federal University of Lavras - UFLA. The coffee samples were subjected to irradiation doses: 0 (control), 5 kGy and 10 kGy, a multipurpose irradiator of IPEN - Research Institute of Nuclear Energy and the University of São Paulo, at a rate of 7.5 kGy / hour. For irradiation the samples were vacuum-packed in appropriate packaging aluminised. After the process of irradiation the samples were stored at a temperature of 15 ± 1 deg C and relative humidity of 17 ± 1%. The following analyzes were performed: levels of total sugars, glucose, sucrose, caffeine, humidity, pH, total acidity, electrical conductivity and fibers. Analyses were performed 1, 30, 60 and 90 days after irradiation, and the results were submitted to analysis of variance and means were compared by Tukey test at 5%. It was observed that the analysis results of the samples irradiated with 5 kGy and 10 kGy showed values similar to the control. It was concluded that irradiation did not induce deleterious effects on arabica coffee seeds and conillon irradiated with 5 kGy and 10 kGy to 90 days after irradiation. (author)

  6. Electronic equilibrium as a function of depth in tissue from cobalt-60 point source exposures

    International Nuclear Information System (INIS)

    Myrick, J.A.

    1994-08-01

    The Nuclear Regulatory Commission has set the basic criteria for assessing skin dose stemming from hot particle contaminations. Compliance with 10 CFR 20.101 requires that exposure to the skin be evaluated over a 1 cm 2 area at a depth of 0.007 cm. Skin exposure can arise from both the beta and gamma components of radioactive particles and gamma radiation can contribute significantly to skin doses. The gamma component of dose increases dramatically when layers of protective clothing are interposed between the hot particle source and the skin, and in cases where the hot particle is large in comparison to the range of beta particles. Once the protective clothing layer is thicker than the maximum range of the beta particles, skin dose is due solely to gamma radiation. Charged particle equilibrium is not established at shallow depths. The degree of electronic equilibrium establishment must be assessed for shallow doses to prevent the over-assessment of skin dose because conventional fluence-to-dose conversion factors are not applicable. To assess the effect of electronic equilibrium, selected thicknesses of tissue equivalent material were interposed between radiochromic dye film and a 60 Co hot particle source and dose was measured as a function of depth. These measured values were then compared to models which are used to calculate charged particle equilibrium. The Miller-Reece model was found to agree closely with the experimental data while the Lantz-Lambert model overestimated dose at shallow depths

  7. New data on the self-absorption of betas in cobalt-60 hot particles

    International Nuclear Information System (INIS)

    Lantz, M.W.; Steward, J.B.

    1988-01-01

    The authors demonstrated that standard dose calculation methods for hot particles could seriously overestimate the beta dose rate component to skin. The reason-self-absorption within an activated satellite particle that has a finite thickness can lead to dramatic reductions in beta output, as compared to that predicted by calculation models that assume the particle has zero thickness. In this paper, the authors demonstrate the self-absorption effect with a particle model and confirmed it with measurements on two high-activity Co-60 particles found at the Palo Verde Nuclear Power Station. The authors then described a method for using an Eberline RO-2 ion chamber survey instrument to estimate the beta dose rate reduction related to self-absorption within a particle. This method relied on the comparison of the uncorrected beta/gamma ratio [(open window-closed window) divided-by closed window] for a particle expected of exhibiting self-absorption to the ratio obtained for a particle of zero thickness

  8. Dose calculation method with 60-cobalt gamma rays in total body irradiation

    International Nuclear Information System (INIS)

    Scaff, Luiz Alberto Malaguti

    2001-01-01

    Physical factors associated to total body irradiation using 60 Co gamma rays beams, were studied in order to develop a calculation method of the dose distribution that could be reproduced in any radiotherapy center with good precision. The method is based on considering total body irradiation as a large and irregular field with heterogeneities. To calculate doses, or doses rates, of each area of interest (head, thorax, thigh, etc.), scattered radiation is determined. It was observed that if dismagnified fields were considered to calculate the scattered radiation, the resulting values could be applied on a projection to the real size to obtain the values for dose rate calculations. In a parallel work it was determined the variation of the dose rate in the air, for the distance of treatment, and for points out of the central axis. This confirm that the use of the inverse square law is not valid. An attenuation curve for a broad beam was also determined in order to allow the use of absorbers. In this work all the adapted formulas for dose rate calculations in several areas of the body are described, as well time/dose templates sheets for total body irradiation. The in vivo dosimetry, proved that either experimental or calculated dose rate values (achieved by the proposed method), did not have significant discrepancies. (author)

  9. Guidelines for industrial radiation sterilization of disposable medical products (Cobalt-60 gamma irradiation)

    International Nuclear Information System (INIS)

    1990-01-01

    This IAEA document is aimed at providing necessary guidance on standards and criteria and assistance to Member States, particularly developing countries, in their attempts to properly set up facilities for industrial radiation sterilization of duly-manufactured medical products by exposure to Co-60 gamma radiation. The contents of the guidelines have therefore been designed, as far as practicable, to reflect the practices and procedures currently employed in the processing of the majority of the radiation-sterilized medical products being produced worldwide. Consequently, this document has attempted to present to its users, for information and for action, all the relevant features of the standard criteria as are currently in existence under the auspices of the various authoritative national and/or regional Codes or Guides. The potential user(s) from Member States are expected to freely decide which of the various standards as enumerated in the Guidelines document should be considered for inclusion or exclusion either partially or totally in the context of the formulation of their own nationally-acceptable guidelines. Refs and tabs

  10. Graft polymerization of styrene onto starch by simultaneous cobalt-60 irradiation

    International Nuclear Information System (INIS)

    Fanta, G.F.; Burr, R.C.; Doane, W.M.; Russell, C.R.

    1977-01-01

    Starch-g-polystyrene copolymers have been prepared by the simultaneous 60 Co irradiation of starch--styrene mixtures, and copolymers have been characterized with respect to weight per cent polystyrene (% add-on) and also the molecular weight and molecular weight distribution of polystyrene grafts. In a typical polymerization, 4g each of starch and styrene were blended with 1 ml water and 1.5 ml of an organic solvent; the resulting semisolid paste was irradiated to a total dose of 1 Mrad. With ethylene glycol, acetonitrile, ethanol, methanol, acetone, and dimethylformamide as the organic solvent, values for % add-on ranged from 24% to 29%. The highest % add-on (43%) and the highest conversion of styrene to grafted polymer (76%) were obtained when the organic solvent was omitted, and water alone was used. When water was also omitted, polymerization of styrene was negligible; however, graft copolymer was formed in the absence of water when either ethylene glycol or ethanol was added. Attempts were unsuccessful to achieve a % add-on greater than 43% by doubling the amount of styrene in the polymerization recipe. Mixtures of equal weights of starch and styrene are relatively nonviscous, but these mixtures thicken when either water or ethylene glycol is blended in. Reasons for this thickening action and the possible influence of thickening on the graft polymerization reaction were explored

  11. Effect of cobalt-60 gamma irradiation on viability of soybean (glycine max. l) seed

    International Nuclear Information System (INIS)

    Addai, Isaac Kwahene

    2001-12-01

    The rapid rate of deterioration and low viability of soybean seeds particularly in storage is a major constraint to its production in the subtropical and tropical areas. Various approaches have been made to solve this problem but they have centred mainly on the control of the environment. Experimental mutagenesis is one of the ways by which genetic variability could be created to serve as basis for selection. In this study, induced mutations were used to create genetic variation and mutants with improved storability selected to provide a more lasting solution to this problem. Seeds of three soybean varieties - Gmx 92-6-10, Gmx 92-5-4E and TGX 87D- 1303 were subjected to four (4) months ambient storage and three accelerated ageing tests. The germination percentages computed 7 days after planting showed that 20% ethanol solution better mimicked ambient storage than 20% methanol solution and the 75°C hot water. In the radiation dosage response studies, dry seeds containing 10% moisture from the three varieties were subjected to 0, 50, 100, 150, 200 and 250 Gy doses of 60Co gamma rays at Ghana Atomic Energy Commission, Kwabenya and sown. The 250 Gy dose reduced both germination percentage and plant height by about 50% relative to the control and was used as the dosage appropriate for induced mutations for the varieties. Five thousand M2 plants were harvested and screened individually for improved storability using 20% ethanol solution, storing threshed seeds at ambient condition and storing seeds in pods also at ambient conditions. The 20% ethanol solution was less effective in selecting putative in mutants compared to the two ambient storage screening methods, but could be used as an initial screening method. The variety Gmx 92-6-10 was generally considered to give the greatest response to irradiation because it produce the largest proportion of putative mutant improved storability in two out of the three screening methods used at the M2 generation. Since TGX 87D 1

  12. SU-E-T-623: Polarity Effects for Small Volume Ionization Chambers in Cobalt-60 Beams

    Energy Technology Data Exchange (ETDEWEB)

    Xu, Y; Bhatnagar, J; Huq, M Saiful [Department of Radiation Oncology, University of Pittsburgh Cancer Institute and UPMC Cancer Center, Pittsburgh, PA (United States)

    2015-06-15

    Purpose: To investigate the polarity effects for small volume ionization chambers in {sup 60}Co gamma-ray beams using the Leksell Gamma Knife Perfexion. Methods: Measurements were made for 7 small volume ionization chambers (a PTW 31016, an Exradin A14, 2 Capintec PR0-5P, and 3 Exradin A16) using a PTW UNIDOSwebline Universal Dosemeter and an ELEKTA solid water phantom with proper inserts. For each ion chamber, the temperature/pressure corrected electric charge readings were obtained for 16 voltage values (±50V, ±100V, ±200V, ±300V, ±400V, ±500V, ±600V, ±700V). For each voltage, a five-minute leakage charge reading and a series of 2-minute readings were continuously taken during irradiation until 5 stable signals (less than 0.05% variation) were obtained. The average of the 5 reading was then used for the calculation of the polarity corrections at the voltage and for generating the saturation curves. Results: The polarity effects are more pronounced at high or low voltages than at the medium voltages for all chambers studied. The voltage dependence of the 3 Exradin A16 chambers is similar in shape. The polarity corrections for the Exradin A16 chambers changes rapidly from about 1 at 500V to about 0.98 at 700V. The polarity corrections for the 7 ion chambers at 300V are in the range from 0.9925 (for the PTW31016) to 1.0035 (for an Exradin A16). Conclusion: The polarity corrections for certain micro-chambers are large even at normal operating voltage.

  13. Effect on treatment planning based on properties of Cobalt-60 stereotactic radiosurgery units

    International Nuclear Information System (INIS)

    Nakazawa, Hisato; Komori, Masataka; Uchiyama, Yukio; Hagiwara, Masahiro; Hayashi, Naoki

    2014-01-01

    The brand-new version of gamma knife, Perfexion, is equipped with an automatic collimator arrangement system that does not require manual collimator exchange and a couch-traveling system that is approximately ten times faster than Model C, so treatment time with multiple shots is assumed to remain within a clinically acceptable range. In this study, the treatment plans for Model C and Perfexion were compared from the viewpoint of number of shots, coverage, selectivity, conformity, and gradient in planning target volume (PTV) coverage. We enrolled 187 and 89 patients with vestibular schwannomas treated by Model C and Perfexion in the study. Treatment planning was created on a Leksell GammaPlan workstation. The mean PTV was 5.2 ml (range 0.1-18.4 ml) in Model C and 4.1 ml (range 0.1-32.1 ml) in Perfexion. The mean shot number for Model C and Perfexion was 11 (range 2-27) and 16 (range 1-41) at the isodose contour of 40-60%, respectively. The mean PTV coverage was 94% (range 73-100%) and 98% (range 91-100%), and the mean PTV selectivity was 83% (range 46-98%) and 87% (range 63-97%) for Model C and Perfexion, respectively. The mean conformity index was 1.15 (range 0.81-2.02) and 1.14 (range 0.97-1.57), and the mean gradient index was 2.82 (range 2.37-3.35) and 2.91 (range 2.55-4.48) for Model C and Perfexion, respectively. In Perfexion, better PTV coverage and selectivity were achieved by using an excessively large number of shots. In addition, the use of a small collimator in Perfexion produced a steeper dose gradient. Our comparative research demonstrated the greater clinical usefulness of Perfexion. (author)

  14. Scanning electron microscopy of mouse intestinal mucosa after cobalt 60 and D-T neutron irradiation

    International Nuclear Information System (INIS)

    Hamlet, R.; Carr, K.R.; Toner, P.G.; Nias, A.H.W.

    1976-01-01

    The stem-cell population of the intestinal crypt is an important model system in experimental radiobiology. Standardized techniques have been developed to allow quantitation of the response of crypt cells to radiation injury following doses of 0 to 2 krad of D-T neutrons or 60 Co γ rays. These techniques rely on the identification of regenerating crypt cells three-and-a-half days after irradiation. The results were expressed as the number of regenerating crypts per circumference of small intestine, as determined by conventional histological examination; the more profound the injury, the smaller the the crypt count. The practical relevance of crypt-counting techniques to clinical radiotherapy is limited by their relative insensitivity; the dose levels commonly used in fractionated radiotherapy produced no detectable response. Scanning electron microscopy of the mucosal surface provided a more sensitive measure of radiation injury. The earliest detectable changes occurred at the level of 300 rad of γ radiation, well below the threshold of the crypt-counting technique. At around 1,000 rad, where the first drop in crypt counts occurred, there were well-marked morphological changes which became more severe with increasing dose levels. Some differences have been observed between the morphological effects of γ and neutron irradiation at points of radiobiological equivalence in terms of crypt counts (using RBE value of about 2). The changes observed may reflect more than the disruption of epithelial cell kinetics. Mucosal morphology is the total expression of many different biological parameters of which the regenerative ability of the crypt cells is only one. The surface microanatomy of the gut may be the most sensitive indicator of radiation injury which is conveniently available for study. (author)

  15. Selective extraction of cobalt 60 and radium on CSA's SIMTM system

    International Nuclear Information System (INIS)

    Denton, M.S.; Higgins, I.R.

    1988-01-01

    CSA, has developed and promoted a new ground/well water treatment media and support system for hydrogen sulfide, iron, and manganese called The SIM System. This media was also found to have a selective affinity for arsenic, selenium, antimony, bismuth and lead. All heavy metals have not been checked, but of special rad-waste interest is Co-60 and Ra-226. Barium has been used as a stand-in for Ra in the lab, but both Co and Ba have exhibited very high affinities from Oak Ridge waters. A very attractive feature is that the adsorbed metals may be eluted with a minimum of acid, unlike ion exchangers that regenerate with difficulty or zeolites which dissolve in acids. This opens up the new dimension of extraction/concentration of these contaminants. Ordinary water softening ion exchange resin is excellent for extraction of Ra from drinking water, but, as mentioned, regenerates with great difficulty. The SIM media may be used for pre-treatment with the acid regenerant reloaded on ordinary resin for a very high concentration of Ra, or Co, for final disposal. The very stable SIM media may also be disposed of directly. Strontium (Sr-90) affinity isn't as great as for barium, but is greater than calcium. The separation factor of SIM for Sr/Ca may well be better than the value of two (2) observed for ordinary cation resin. Further studies are being made to demonstrate the full potential of this selective media for certain rad-wastes

  16. Scanning electron microscopy of mouse intestinal mucosa after cobalt 60 and D-T neutron irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Hamlet, R [Belvidere Hospital, Glasgow (UK). Institute of Radiotherapeutics and Oncology; Carr, K R; Toner, P G; Nias, A H.W.

    1976-07-01

    The stem-cell population of the intestinal crypt is an important model system in experimental radiobiology. Standardized techniques have been developed to allow quantitation of the response of crypt cells to radiation injury following doses of 0 to 2 krad of D-T neutrons or /sup 60/Co ..gamma.. rays. These techniques rely on the identification of regenerating crypt cells three-and-a-half days after irradiation. The results were expressed as the number of regenerating crypts per circumference of small intestine, as determined by conventional histological examination; the more profound the injury, the smaller the the crypt count. The practical relevance of crypt-counting techniques to clinical radiotherapy is limited by their relative insensitivity; the dose levels commonly used in fractionated radiotherapy produced no detectable response. Scanning electron microscopy of the mucosal surface provided a more sensitive measure of radiation injury. The earliest detectable changes occurred at the level of 300 rad of ..gamma.. radiation, well below the threshold of the crypt-counting technique. At around 1,000 rad, where the first drop in crypt counts occurred, there were well-marked morphological changes which became more severe with increasing dose levels. Some differences have been observed between the morphological effects of ..gamma.. and neutron irradiation at points of radiobiological equivalence in terms ofCrypt counts (using RBE value of about 2). The changes observed may reflect more than the disruption of epithelial cell kinetics. Mucosal morphology is the total expression of many different biological parameters of which the regenerative ability of the crypt cells is only one. The surface microanatomy of the gut may be the most sensitive indicator of radiation injury which is conveniently available for study.

  17. Fission product gamma-ray sources as an alternative to cobalt-60 sources for sewage sludge sterilization

    International Nuclear Information System (INIS)

    Herrnberger, V.R.D.

    1975-01-01

    The sterilization of sewage sludge is now performed successfully using 60 Co gamma-ray sources. The question arises whether more economic gamma-ray sources exist that could replace the 60 Co source. The following types of sources are considered: Spent fuel elements; mixtures of solidified fission products; and isolated solidified fission products such as 134 / 137 Cs. For a particular irradiation plant the specific source costs (S.Fr./Ci) and their contribution to the irradiation costs for 1 m 3 of sewage irradiated to a dose of 250 krad(S.Fr./m 3 ) are determined and compared with the costs of a plant using a 60 Co source. The encapsulation costs and the effect of the gamma absorption of the source are taken into account. Different encapsulation and source management techniques are reviewed to find the most economic for each source type. A spent fuel element irradiation facility is recommended for use either in combination with a sewage water purification plant or as part of a power reactor station where it replaces the storage water pool for the spent fuel elements. Additional source capsules are not envisaged, as long as double-walled source containers are used. The fission product mixtures are enclosed in double-walled capsules of two different forms: Small cylindrical rods and hollow cylinders. For caesium and cobalt cylindrical rods only are used. The main conclusions of the study are that the highest irradiation costs arise from the use of a fission product mixture source. The costs are, however, only 15% above those of a 60 Co plant. To be competitive the flow-rate has to be adapted to the decreasing activity of the source, resulting in a reduction to 20% within ten years of source utilization. The integrated irradiation plant with a spent fuel element source offers irradiation costs comparable with those of a 60 Co plant, if the flow-rate is constant during one year of source utilization. The irradiation costs are reduced to 25% of those of a 60 Co plant

  18. Experiences on the implementation of a postal auditing service to know teletherapy doses using Cobalt 60 attained by the Secondary laboratory for dosimetric calibration from CPHR

    International Nuclear Information System (INIS)

    Campa, R.; Morales, J.A.; Molina, D.; Dominguez, L.

    1998-01-01

    This paper analyzes experiences gained by LSCD from CPHR on the implementation and validation of a postal auditing system. The system checks doses absorbed by water for teletherapy equipment using Cobalt 60. The verification was made with Chinese DTL type JR 1152F (microbars) introduced in capsules developed and employed by IAEA in the postal auditing service for doses IAEA/WHO. The analysis includes the creation of groups of detectors based on their individual sensibility. They have a dispersion range that was almost 2%. Here irradiation was applied to a water dummy. Other tests employed were that for thermal treatment and calibration. Besides one auditing the effectiveness of the postal technique in two facilities using Cobalt 60. The methodology implemented helps to determine doses absorbed in reference conditions with a lower global uncertainty (k=2) (3.2%)

  19. Effect of antioxidants on thiobarbituric acid reactive substances of mechanically de boned chicken meat irradiated with ionizing radiation: cobalt-60 and electron beam sources

    International Nuclear Information System (INIS)

    Brito, Poliana de Paula; Azevedo, Heliana de; Pomarico Neto, Walter; Roque, Claudio Vitor; Brusqui, Armando Luiz; Haguiwara, Marcia Mayumi Harada; Miyagusku, Luciana

    2011-01-01

    Samples of MDCM with skin were divided into three groups: control (without antioxidants), Antioxidant 1 - A1 (0.3% Sodium Polyphosphate and Sodium Erythorbate 0.05%) and Antioxidant 2 - A2 (Rosemary Extract 0.02% and α-Tocopherol 0.01%). The three batches of samples were divided into nine groups: no antioxidant and non-irradiated (Cn/I), with antioxidant A1 and non-irradiated (A1n/I), with antioxidant A2 and non-irradiated (A2n/I) without antioxidant and irradiated in Cobalt-60 source (CCo), with antioxidant A1 irradiated in Cobalt 60 source (A1Co) with antioxidant A2 irradiated in Cobalt-60 source (A2Co) with antioxidant A1 irradiated in Electron beam (A1Eb) and with antioxidant A2 irradiated in Electron beam (A2Eb). Each 100 g sample was conditioned in a transparent, low density polyethylene oxygen permeable bag, frozen overnight at a temperature of -18 +- 1 deg C in a chamber, and irradiated in this state, maintaining the temperature low with dry ice. The samples were irradiated with a dose of 3.0 kGy, used two sources of radiation: Cobalt-60 (3.1 kGy.h -1 ) and electron beam (2.9 kGy.s -1 ). After this process, the samples were evaluated during the refrigeration period (2 +- 1 deg C) for 11 days for the following analysis: total psychotropic bacteria count, thiobarbituric acid reactive substances (TBARS). The addition of antioxidants was able to reduce lipid oxidation caused by the irradiation. There were no differences between the radiation sources used in the same parameters. The better antioxidants mixture in the TBARS reducing it was rosemary extract and α-tocopherol (A2). (author)

  20. Effect of antioxidants on thiobarbituric acid reactive substances of mechanically de boned chicken meat irradiated with ionizing radiation: cobalt-60 and electron beam sources

    Energy Technology Data Exchange (ETDEWEB)

    Brito, Poliana de Paula; Azevedo, Heliana de; Pomarico Neto, Walter; Roque, Claudio Vitor; Brusqui, Armando Luiz, E-mail: hgomes@cnen.gov.b, E-mail: pbrito@cnen.gov.b, E-mail: cvroque@cnen.gov.b, E-mail: abrusqui@cnen.gov.b [Brazilian Nuclear Energy Commission (LAPOC/CNEN), Pocos de Caldas, MG (Brazil); Haguiwara, Marcia Mayumi Harada; Miyagusku, Luciana, E-mail: marciamh@ital.gov.b, E-mail: lucianam@ital.gov.b [Food Technology Institute (ITAL), SP (Brazil). Meat Technology Center

    2011-07-01

    Samples of MDCM with skin were divided into three groups: control (without antioxidants), Antioxidant 1 - A1 (0.3% Sodium Polyphosphate and Sodium Erythorbate 0.05%) and Antioxidant 2 - A2 (Rosemary Extract 0.02% and {alpha}-Tocopherol 0.01%). The three batches of samples were divided into nine groups: no antioxidant and non-irradiated (Cn/I), with antioxidant A1 and non-irradiated (A1n/I), with antioxidant A2 and non-irradiated (A2n/I) without antioxidant and irradiated in Cobalt-60 source (CCo), with antioxidant A1 irradiated in Cobalt 60 source (A1Co) with antioxidant A2 irradiated in Cobalt-60 source (A2Co) with antioxidant A1 irradiated in Electron beam (A1Eb) and with antioxidant A2 irradiated in Electron beam (A2Eb). Each 100 g sample was conditioned in a transparent, low density polyethylene oxygen permeable bag, frozen overnight at a temperature of -18 +- 1 deg C in a chamber, and irradiated in this state, maintaining the temperature low with dry ice. The samples were irradiated with a dose of 3.0 kGy, used two sources of radiation: Cobalt-60 (3.1 kGy.h{sup -1}) and electron beam (2.9 kGy.s{sup -1}). After this process, the samples were evaluated during the refrigeration period (2 +- 1 deg C) for 11 days for the following analysis: total psychotropic bacteria count, thiobarbituric acid reactive substances (TBARS). The addition of antioxidants was able to reduce lipid oxidation caused by the irradiation. There were no differences between the radiation sources used in the same parameters. The better antioxidants mixture in the TBARS reducing it was rosemary extract and {alpha}-tocopherol (A2). (author)

  1. Determination of dosimetric parameters of Asymmetric fields from those of Symmetric fields for equinox 100 Cobalt-60 teletherapy machine

    International Nuclear Information System (INIS)

    Mensah, K.

    2014-07-01

    The Theratron Equinox 100 Cobalt-60 therapy unit is equipped wtih x-ray collimators or jaws that can be moved independently or allow asymmetric fields with field centres positioned away from the true central axis of the beam. Although asymmetric collimation can be performed by beam splitters or secondary blocking on a shadow tray; an independent jaw feature reduces the set-up time and spares the therapist from handling heavy blocks. Clinical sites where asymmetric jaws are typically used include breast, head and neck, craniospinal and prostate. Knowledge of the dose distribution of asymmetric fields is required to help evaluate the dosimetry of this non-standard treatment delivery technique prior to clinical implementation. IBA StarTrack 2-D array was used to acquire beam profiles of symmetric and asymmetric beams of different field sizes and varying depth using the Theratron Equinox 100 Cobalt-60 teletherapy unit. The 2-D water phantom was then used to measure PDDs and output factors of both the symmetric and asymmetric beams at varying depths and field sizes. The off-axis ratio was also determined from the half beam profile of the largest field size of the treatment machine and then the output factor ratios were used to validate it. The treatment planning system was then used to model both the symmetric and asymmetic beams and the PDDs and output factors were also calculated. Beam profiles for asymmetry beams showed good agreement with symmetry beam profiles for smaller field sizes and the deviations among them steadily became more evident with increasing field sizes. This difference in the dose distribution for asymmetric fields compared to the dose distribution for symmetric fields was due to the tilt of the dose profiles towards the beam axis. This tilt in the dose profiles of the asymmetic beams was caused by the oblique incidence of the asymmetric beam at off-axis locations, causing less beam hardening compared to that along the central axis. In treatment

  2. Dosimetry characterization of the Tunisian Cobalt-60 gamma irradiation pilot plant for the irradiation of the mediterranean fruit fly

    International Nuclear Information System (INIS)

    Bettaieb, Nasreddine; Farah, Kaled; Kadri, Omrane; Jerbi, Taieb; Gharbi, Foued; Manai, Kais

    2005-01-01

    Cobalt-60 gamma irradiation pilot plant has been put into operation in 1999 at the National Center for nuclear scinces and technologies, Sidi-Thabet, Tunisia. An initial characterization of this pilot was performed to determine the overall performance of the irradiator in delivering absorbed dose to a product prior to routine processing, in particular sterilisation of medical devices and food irradiation. A new irradiation holder was recently installed; it was designed especially for the irradiation of pupae of the Meditterranean fruit fly. It consists of four turn plates which makes it possible to rotate the canisters holding the pupae within the radiation field. The axis of ratation is vertical and parallel to the source pencils. Prior to routine irradiation using the new irradiation holder, validation procedures are necessary to establish conditions of the irradiation within the specification. In the course of these procedures, detailed dose mapping on a vertical plane in the middel of the canister of insect pupae with bulk density of 0.446 g /cm3 was carried out for two irradiation configurations : fixed plates and turned plates. GafChromic dosimeter calibrated against Alanine / ESR dosimetry system was used for the dose measurements. The maximum and minimum dose locations were determined and the dose uniformity ratio calculated and discussed. Detailed analyses of the isodose curves and histogram of the frequency distribution of absorbed dose were also given. Transit dose and dose rate in the reference position inside the canister were measured using Fricke dosimeters. The results of measurements of absorbed dose and dose distribution in insect pupae do not show any significant difference in the dose uniformity ratio (U=Dmax / Dmin) between the two irradiation configurations. At the same time we observed with turned plates configuration an improvement of the homogeneity of the absorbed dose distribution in the insect pupae showed by the increasing of the pipae

  3. Analysis of Gafchromic EBT3 film calibration irradiated with gamma rays from different systems: Gamma Knife and Cobalt-60 unit.

    Science.gov (United States)

    Najafi, Mohsen; Geraily, Ghazale; Shirazi, Alireza; Esfahani, Mahbod; Teimouri, Javad

    2017-01-01

    In recent years, Gafchromic films are used as an advanced instrument for dosimetry systems. The EBT3 films are a new generation of Gafchromic films. Our main interest is to compare the response of the EBT3 films exposed to gamma rays provided by the Theratron 780C as a conventional radiotherapy system and the Leksell Gamma Knife as a stereotactic radiotherapy system (SRS). Both systems use Cobalt-60 sources, thus using the same energy. However, other factors such as source-to-axis distance, number of sources, dose rate, direction of irradiation, shape of phantom, the field shape of radiation, and different scatter contribution may influence the calibration curve. Calibration curves for the 2 systems were measured and plotted for doses ranging from 0 to 40 Gy at the red and green channels. The best fitting curve was obtained with the Levenberg-Marquardt algorithm. Also, the component of dose uncertainty was obtained for any calibration curve. With the best fitting curve for the EBT3 films, we can use the calibration curve to measure the absolute dose in radiation therapy. Although there is a small deviation between the 2 curves, the p-value at any channel shows no significant difference between the 2 calibration curves. Therefore, the calibration curve for each system can be the same because of minor differences. The results show that with the best fitting curve from measured data, while considering the measurement uncertainties related to them, the EBT3 calibration curve can be used to measure the unknown dose both in SRS and in conventional radiotherapy. Copyright © 2017. Published by Elsevier Inc.

  4. Radioprotective activity of curcumin-encapsulated liposomes against genotoxicity caused by Gamma Cobalt-60 irradiation in human blood cells.

    Science.gov (United States)

    Nguyen, Minh-Hiep; Pham, Ngoc-Duy; Dong, Bingxue; Nguyen, Thi-Huynh-Nga; Bui, Chi-Bao; Hadinoto, Kunn

    2017-11-01

    While the radioprotective activity of curcumin against genotoxicity has been well established, its poor oral bioavailability has limited its successful clinical applications. Nanoscale formulations, including liposomes, have been demonstrated to improve curcumin bioavailability. The objective of the present work was (1) to prepare and characterize curcumin-encapsulated liposomes (i.e. size, colloidal stability, encapsulation efficiency, and payload), and (2) subsequently to evaluate their radioprotective activity against genotoxicity in human blood cells caused by Gamma Cobalt-60 irradiation. The curcumin-encapsulated liposomes were prepared by lipid-film hydration method using commercial phosphatidylcholine (i.e. Phospholipon ® 90G). The blood cells were obtained from healthy male donors (n = 3) under an approved ethics protocol. The cell uptake and the radioprotective activity of the curcumin-encapsulated liposomes were characterized by fluorescence microscopy and micronucleus assay, respectively. Nanoscale curcumin-encapsulated liposomes exhibiting good physical characteristics and successful uptake by the human blood cells were successfully prepared. The radioprotective activity of the curcumin-encapsulated liposomes was found to be dependent on the curcumin concentration, where an optimal concentration existed (i.e. 30 μg/mL) independent of the irradiation dose, above which the radioprotective activity had become stagnant (i.e. no more reduction in the micronuclei frequency). The present results established for the first time the radioprotective activity of curcumin-encapsulated liposomes in human blood cells, which coupled by its well-established bioavailability, boded well for its potential application as a nanoscale delivery system of other radioprotective phytochemicals.

  5. Aspect of sucrose and its monomers from sugarcane juice submitted to different doses of cobalt-60 irradiation

    International Nuclear Information System (INIS)

    Lima, Roberta B.; Rela, Paulo; Arthur, Valter; Souza, Juliana Ap.; Prezotto, Mariane P.; Baptista, Antonio S.; Aguiar, Claudio L.

    2011-01-01

    /h by Cobalt-60, to those doses analyzed, were not sufficient to modify the sugars profiles found in sugarcane juice, indicating viability to use of gamma irradiation technology on sugar and energy industry, either as an alternative to the clarification (for pigment degradation) in crystal sugar or sterilization process of sugarcane juice. (author)

  6. Aspect of sucrose and its monomers from sugarcane juice submitted to different doses of cobalt-60 irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Lima, Roberta B.; Rela, Paulo [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil); Arthur, Valter, E-mail: arthur@cena.usp.br [Centro de Energia Nuclear da Agricultura (CENA/USP), Piracicaba, SP (Brazil). Dept. de Radiobiologia e Ambiente; Souza, Juliana Ap.; Prezotto, Mariane P.; Baptista, Antonio S.; Aguiar, Claudio L., E-mail: claguiar@esalq.usp.br [Escola Superior de Agricultura Luiz de Queiroz (ESALQ/USP), Piracicaba, SP, (Brazil). Dept. de Agroindustria, Alimentos e Nutricao

    2011-07-01

    emitted to dose rate of 3.88 KGy/h by Cobalt-60, to those doses analyzed, were not sufficient to modify the sugars profiles found in sugarcane juice, indicating viability to use of gamma irradiation technology on sugar and energy industry, either as an alternative to the clarification (for pigment degradation) in crystal sugar or sterilization process of sugarcane juice. (author)

  7. A Measurement and Analysis of Buildup Region Dose for Open Field Photon Beams (Cobalt-60 through 24 MV)

    International Nuclear Information System (INIS)

    McCullough, Edwin C.

    2015-01-01

    The central axis depth dose in the build-up region (surface to d_m_a_x) of single open field photon beams (cobalt-60 through 24 MV) has been measured utilizing parallel plate and extrapolation chamber methodology. These data were used to derive, for a prescription dose of 100 cGy, values of surface dose, the maximum value of dose along the central axis (D_m_a_x) and the depth (nearest the surface) at which 90% of the prescription dose occurs (d_9_0). For both single and parallel opposed pair (POP) open field configurations, data are presented at field sizes of 5 × 5, 15 × 15 and 25 × 25 cm"2 for prescription depths of 10, 15 and 20 cm (midplane for POP). For the treatment machines, field sizes, and prescription depths studied, it is possible to conclude that: for single open field irradiation, surface dose values (as a percentage of the prescription dose) can be either low (<10%) or comparable to the prescription dose itself; for POP open fields, surface dose values are relatively independent of photon energy and midplane depth, and range between 30% and 70% of prescription dose, being principally dependent on field size; the depth of the initial 90 cGy point for a prescription dose of 100 cGy, d_9_0, was larger for POP fields. For either single or POP open field treatments, d_9_0 was always less than 22 mm, while for 6 MV or less, values of d_9_0 were less than 4 mm; D_m_a_x values can be very large (e.g., above 300 cGy) for certain treatment situations and are reduced significantly for POP treatments; for open field POP treatments, the percent reduction in D_m_a_x with each increment in beam energy above 10 MV is reduced over that seen at 10 MV or less and, possibly, this further reduction may be clinically insignificant; for open field POP treatments, changes in surface dose, d_9_0 and D_m_a_x with beam energy above 10 MV do not suggest, with regard to these specific build-up curve parameters, any obvious advantage for treatment with beam energies greater

  8. Effects of gamma radiation from Cobalt-60 on pequi fruits (Caryocar brasiliense Camb.);Efeitos da radiacao gama do Cobalto-60 em frutos de pequi (Caryocar brasiliense Camb.)

    Energy Technology Data Exchange (ETDEWEB)

    Santos, Marcio Ramatiz Lima dos

    2008-07-01

    The aim of this work was to evaluate gamma radiation effects from Cobalt-60 on post harvest characteristics of pequi fruits (Caryocar brasiliense Camb.). Brazilian savannah is the second biome of American Continent and concentrate a lot of plants and animal species. Many plants and their fruits are still unknown of Brazilian population. Just now, they are gained attention of researchers due their nutritional properties, between then is the pequi fruits. Fruits come from Goias State was classified, washed and processed to separate the endocarp (edible part) from pericarp. The endocarps were packing in polyethylene bags with 150 g, labeled and submitted to radiation process (0.0, 0.4, 0.6 and 1.0 kGy doses) on multipurpose irradiator located in IPEN/USP. The samples were analyzed to chemical (pH, trititable acidity, Deg Brix, ratio TSS/TTA, lipids, ash, humidity, protein, soluble and insoluble fiber, total carotenoids and antioxidant activity) and physical properties (loss weight, texture and color). The loss humidity was proportional to radiation applied doses, the highest loss was observed on fruits to 1.0 kGy doses. Soluble fiber and protein showed no significant differences between treatments. Ash, insoluble fiber, dry matter and lipids showed little significant differences. Significant decrease of the pH values was observed for the irradiated samples in relation to control. Irradiated samples texture showed significant increase compared to control, but showed no significant differences between applied doses. The higher value for texture was (39.89 Newton g-1) for 0.6 kGy dose. Total soluble solids (TSS) showed a significant decrease compared to control, but was not significant between applied treatments. Titratable acidity showed a significant decrease for irradiated samples compared to control for all doses, but it was not significant between treatments. The ratio TSS/TTA showed no significant differences compared to control, only for irradiated fruits at 0.6 k

  9. Effects of gamma radiation of Cobalt-60 on different phases of the evolutive cycle of pinworm - Tuta absoluta (Meyrich, 1917) (Lepidoptera,Gelechiidae)

    International Nuclear Information System (INIS)

    Groppo, Gerson Antonio

    1996-10-01

    The effects of different gamma radiation (Cobalt-60) doses on different phases of the evolutive cycle of Tuta absoluta (Meyrich, 1917) (Lepidoptera, Gelechiidae) have been studied under laboratory conditions in the laboratory of Entomology of Center for Nuclear Energy in Agriculture (CENA), University of Sao Paulo, Piracicaba, Sao Paulo State, Brazil. For all the treatments with gamma radiation a Cobalt-60 source type Gamma beam-650 was used. The doses utilized ranged from of 0,0 (Control) to 3250 Gy with a dose rate of 1110 Gy/h. The experiment was conducted under controlled conditions at 25± 2 deg C, 70 ± 5% of relative humidity and photo period of (12:12). It was verified that the lethal doses were: for eggs - 70 Gy; for larvae - 200 Gy e for pupae - 300 Gy. The sterilizing dose for adults from irradiated larvae was 45 Gy. The sterilizing dose for the crossing of irradiated female with normal males (FI X MN) was 100 Gy and for normal female with irradiated male (FN x MI) was 150 Gy, in the both crosses, doses refer to irradiation of pupae. The sterilizing dose for adults, of both sexes, irradiated and crossed with normal adults, (FI x MN) and (FN x MI, were 150 and 200 Gy, respectively. The average longevity of adults, of both sexes, irradiated and crossed with normal adults was 8,3 days. The immediate lethal dose for adults was 3250 Gy. (author)

  10. Development of the irradiation facility SIBO INRA/Tangier, Morocco by upgrading cobalt-60 in a temporary pool and enhancing safety and control features

    Directory of Open Access Journals (Sweden)

    Mohammed Mouhib

    2017-12-01

    Full Text Available An automatic control system is one of the most important parts of an irradiation facility. The level of this control is always maintained to comply with safety procedures during routine work in this field. Also sometimes it is limited to the minimum level of regulation required due to economical aspects; some commercial systems are generally made by manufacturers of industrial facilities and considered affordable by irradiators. In some cases specific irradiation facilities tailor their control systems to their needs. For this kind of irradiator the control system can be developed and upgraded according to personal and industrial experiences. These upgrading procedures are also used by others to develop their systems. The objective of this paper is to share a local experience in upgrading security, safety systems and the use of cobalt-60 for the irradiator. It is a composite experiment at SIBO INRA/Tangier, Morocco and concerns the: (i upgrade of cobalt-60 in a temporary pool in the SIBO irradiator in Tangier. This operation was conducted in collaboration with the International Atomic Energy Agency (IAEA and was a success story of 2014 according to the general conference of IAEA; (ii safety and technical upgrade of the system in the SIBO irradiator made in collaboration with IAEA; (iii installation and upgrade of the security system in accordance with the Global Threat Reduction Programme (GTRP to reduce the threat of a Radiological Dispersal Device (RDD in collaboration with The United States Department of Energy’s National Nuclear Security Administration (NNSA.

  11. Enhancement of viability of radiosensitive (PBMC and resistant (MDA-MB-231 clones in low-dose-rate cobalt-60 radiation therapy

    Directory of Open Access Journals (Sweden)

    Patrícia Lima Falcão

    2015-06-01

    Full Text Available Abstract Objective: In the present study, the authors investigated the in vitro behavior of radio-resistant breast adenocarcinoma (MDA-MB-231 cells line and radiosensitive peripheral blood mononuclear cells (PBMC, as a function of different radiation doses, dose rates and postirradiation time kinetics, with a view to the interest of clinical radiotherapy. Materials and Methods: The cells were irradiated with Co-60, at 2 and 10 Gy and two different exposure rates, 339.56 cGy.min–1 and the other corresponding to one fourth of the standard dose rates, present over a 10-year period of cobalt therapy. Post-irradiation sampling was performed at pre-established kinetics of 24, 48 and 72 hours. The optical density response in viability assay was evaluated and a morphological analysis was performed. Results: Radiosensitive PBMC showed decrease in viability at 2 Gy, and a more significant decrease at 10 Gy for both dose rates. MDAMB- 231 cells presented viability decrease only at higher dose and dose rate. The results showed MDA-MB-231 clone expansion at low dose rate after 48–72 hours post-radiation. Conclusion: Low dose rate shows a possible potential clinical impact involving decrease in management of radio-resistant and radiosensitive tumor cell lines in cobalt therapy for breast cancer.

  12. Estimation of uranium and cobalt-60 distribution coefficients and uranium-235 enrichment at the Combustion Engineering Company site in Windsor, Connecticut

    International Nuclear Information System (INIS)

    Wang, Y.; Orlandini, K.A.; Yu, C.

    1996-05-01

    Site-specific distribution coefficients for uranium isotopes and cobalt-60 (Co-60) and the fraction of uranium-235 (U-235) enrichment by mass were estimated for environmental samples collected from the Combustion Engineering Company site in Windsor, CT. This site has been identified for remedial action under the US Department of Energy's (DOE) Formerly Utilized Sites Remedial Action Program. The authority of DOE at the Combustion Engineering site is limited to (1) Building 3; (2) other activities or areas associated exclusively with Building 3 (such as sewer lines); or (3) contamination that is exclusively highly enriched uranium. In this study, 16 samples were collected from the Combustion Engineering site, including 8 soil, 4 sediment, 3 water, and 1 water plus sludge sample. These samples were analyzed for isotopic uranium by alpha spectrometry and for Co-60 by gamma spectrometry. The site-specific distribution coefficient for each isotope was estimated as the ratio of extractable radionuclide activity in the solid phase to the activity in the contact solution following a 19-day equilibration. The uranium activity measurements indicate that uranium-234 (U-234) and uranium-238 (U-238) were in secular equilibrium in two soil samples and that soil and sediment samples collected from other sampling locations had higher U-234 activity than U-238 activity in both the solid and solution phases. The site-specific distribution coefficient (Kd) ranged from 82 to 44,600 mL/g for U-238 and from 102 to 65,900 mL/g for U-234. Calculation of U-235 enrichment by mass indicated that four soil samples had values greater than 0.20; these values were 0.37, 0.38, 0.46, and 0.68. Cobalt-60 activity was detected in only three sediment samples. The measured Co-60 activity in the solid phase ranged from 0.15 to 0.45 pCi/g and that in the water phase of all three samples combined was 4 pCi/L. The Kd value for Co-60 in the site brook sediment was calculated to be 70 mL/g

  13. Main aspects in licensing of a type B(U) package design for the transport of 12.95 PBq of cobalt 60

    International Nuclear Information System (INIS)

    Lopez Vietri, J.R.; Novo, R.G.; Bianchi, A.J.

    1995-01-01

    This paper points out the relevant technical issues related to the licensing process, of a type B(U) package design, with cylindrical form and 9.3 ton mass, approved by the Argentine Competent Authority for the transport of 12.95 PBq of cobalt 60 as special form radioactive material. It is briefly described the heat transfer analysis, the structural performance under impulsive loads and the shielding calculation under both normal and accidental conditions of transport, as well as the comparative analysis of the results obtained from design, pre-operational tests and independent evaluation performed by the Argentine Competent Authority to verify the compliance with the Regulations for the Safe Transport of Radioactive Material of the International Atomic Energy Agency. (author). 14 refs., 1 fig., tabs

  14. Effect of different ionizing radiation doses and dose rates, using Cobalt-60 and electrons beam sources, on the staphylococcal enterotoxin inoculated in mechanically deboned chicken meat

    Energy Technology Data Exchange (ETDEWEB)

    Pomarico Neto, Walter; Brito, Poliana de Paula; Azevedo, Heliana de; Roque, Claudio Vitor; Fukuma, Henrique Takuji, E-mail: pbrito@cnen.gov.br, E-mail: hazevedo@cnen.gov.br, E-mail: cvroque@cnen.gov.br, E-mail: htfukuma@cnen.gov.br [Brazilian Nuclear Energy Commission (LAPOC/CNEN), Pocos de Caldas, MG (Brazil); Kodama, Yasko, E-mail: ykodama@ipen.br [Nuclear and Energy Research Institute (IPEN/CNEN-SP), Sao Paulo, SP (Brazil); Miya, Norma Terugo Nago; Pereira, Jose Luiz, E-mail: miya@fea.unicamp.br, E-mail: pereira@fea.unicamp.br [Campinas State University (UNICAMP), SP (Brazil). Dept. of Food Sciences

    2011-07-01

    The purpose of food irradiation is the destruction of present pathogenic microorganisms and the increase of shelf life of foods. To achieve this process, the source of cobalt-60 and the electron accelerator can be used. The mechanically deboned chicken meat (MDCM) is used for the production of traditional meat products, and it may come to present pathogenic microorganisms such as staphylococcus aureus, a bacterium that produces enterotoxin, which causes food poisoning. The objective of this study is to analyze the effect of ionizing irradiation with different doses and dose rates, deriving from different radiation sources, on staphylococcal enterotoxin type B (SEB) in the MDCM. 50 g samples of MDCM were prepared in a batch of 6 kg of MDCM. The samples were contaminated, with the exception of the control, with SEB in amounts of about 100 ng. Then they were conditioned in a transparent bag made of low density polyethylene, frozen at -18{+-}1 deg C overnight and irradiated in these conditions with doses of 0.0 kGy (control), 1.5 kGy and 3.0 kGy, and with three different dose rates, both in the Cobalt-60 and the electron accelerator. The experiments were conducted in quintuplicate. The SEB extraction from the MDCM was performed according to the protocol recommended by the manufacturer of the kit VIDAS Staph Enterotoxin II (bioMerrieux). The principle of mass balance was used to determine the actual amount of SEB removed by irradiation. The treatment that presented the best results was the one with a dose of 1.5 kGy, high dose rate of the electron accelerator. (author)

  15. Effect of different ionizing radiation doses and dose rates, using Cobalt-60 and electrons beam sources, on the staphylococcal enterotoxin inoculated in mechanically deboned chicken meat

    International Nuclear Information System (INIS)

    Pomarico Neto, Walter; Brito, Poliana de Paula; Azevedo, Heliana de; Roque, Claudio Vitor; Fukuma, Henrique Takuji; Kodama, Yasko; Miya, Norma Terugo Nago; Pereira, Jose Luiz

    2011-01-01

    The purpose of food irradiation is the destruction of present pathogenic microorganisms and the increase of shelf life of foods. To achieve this process, the source of cobalt-60 and the electron accelerator can be used. The mechanically deboned chicken meat (MDCM) is used for the production of traditional meat products, and it may come to present pathogenic microorganisms such as staphylococcus aureus, a bacterium that produces enterotoxin, which causes food poisoning. The objective of this study is to analyze the effect of ionizing irradiation with different doses and dose rates, deriving from different radiation sources, on staphylococcal enterotoxin type B (SEB) in the MDCM. 50 g samples of MDCM were prepared in a batch of 6 kg of MDCM. The samples were contaminated, with the exception of the control, with SEB in amounts of about 100 ng. Then they were conditioned in a transparent bag made of low density polyethylene, frozen at -18±1 deg C overnight and irradiated in these conditions with doses of 0.0 kGy (control), 1.5 kGy and 3.0 kGy, and with three different dose rates, both in the Cobalt-60 and the electron accelerator. The experiments were conducted in quintuplicate. The SEB extraction from the MDCM was performed according to the protocol recommended by the manufacturer of the kit VIDAS Staph Enterotoxin II (bioMerrieux). The principle of mass balance was used to determine the actual amount of SEB removed by irradiation. The treatment that presented the best results was the one with a dose of 1.5 kGy, high dose rate of the electron accelerator. (author)

  16. The role of Cobalt-60 source in Intensity Modulated Radiation Therapy: From modeling finite sources to treatment planning and conformal dose delivery

    Science.gov (United States)

    Dhanesar, Sandeep Kaur

    Cobalt-60 (Co-60) units played an integral role in radiation therapy from the mid-1950s to the 1970s. Although they continue to be used to treat cancer in some parts of the world, their role has been significantly reduced due to the invention of medical linear accelerators. A number of groups have indicated a strong potential for Co-60 units in modern radiation therapy. The Medical Physics group at the Cancer Center of the Southeastern Ontario and Queen's University has shown the feasibility of Intensity Modulated Radiation Therapy (IMRT) via simple conformal treatment planning and dose delivery using a Co-60 unit. In this thesis, initial Co-60 tomotherapy planning investigations on simple uniform phantoms are extended to actual clinical cases based on patient CT data. The planning is based on radiation dose data from a clinical Co-60 unit fitted with a multileaf collimator (MLC) and modeled in the EGSnrc Monte Carlo system. An in house treatment planning program is used to calculate IMRT dose distributions. Conformal delivery in a single slice on a uniform phantom based on sequentially delivered pencil beams is verified by Gafchromic film. Volumetric dose distributions for Co-60 serial tomotherapy are then generated for typical clinical sites that had been treated at our clinic by conventional 6MV IMRT using Varian Eclipse treatment plans. The Co-60 treatment plans are compared with the clinical IMRT plans using conventional matrices such as dose volume histograms (DVH). Dose delivery based on simultaneously opened MLC leaves is also explored and a novel MLC segmentation method is proposed. In order to increase efficiency of dose calculations, a novel convolution based fluence model for treatment planning is also proposed. The ion chamber measurements showed that the Monte Carlo modeling of the beam data under the MIMiC MLC is accurate. The film measurements from the uniform phantom irradiations confirm that IMRT plans from our in-house treatment planning system

  17. Distribution of cobalt 60 in a mollusc, a crustacean and a freshwater teleost: variations as a function of the source of pollution and during elimination

    International Nuclear Information System (INIS)

    Amiard, J.C.; Amiard-Triquet, C.

    1979-01-01

    57 Co, 58 Co and 60 Co are present in nuclear test debris as well as in effluents of the non-military nuclear industry. The stable isotope, which is a constituent of vitamin B 12 , has very important biological functions. For each species, three experiments were carried out: (1) starved animals were immersed in 60 Co-contaminated water; (2) animals were immersed in contaminated water and received radioactive food and (3) animals were placed in fresh water without any pollutant but received contaminated food. Radiation doses were calculated for contamination via both food and water. When 60 Co is taken up directly from water, the most contaminated organs are external ones, especially the shell of the snail Lymnaea palustris and the exoskeleton and feeding appendages of the crayfish Astacus leptodactylus. Contamination via food is responsible for a relatively greater accumulation of radiocobalt in internal organs. The cobalt content of muscles - that is to say the edible parts of crayfish and common carp Cyprinus carpio -is very low. The highest concentrations recorded are in the visceral mass of the snail, the digestive gland of the crayfish and the kidneys of the carp. Internal doses for these organs are considerably higher than those for entire animals. Therefore, as a result of 60 Co distribution, they are critical organs for the freshwater species. Except for the carp, external radiation is very weak compared with internal radiation. A strong retention of 60 Co is observed for the shell of L. palustris while the desorption of radiocobalt from the exoskeleton of A. leptodactylus is easier. In carp, the 60 Co taken up by the gut from food, as well as from water, is rapidly eliminated. (author)

  18. Charge yield for cobalt-60 and 10-keV x-ray irradiations of MOS devices

    International Nuclear Information System (INIS)

    Shaneyfelt, M.R.; Fleetwood, D.M.; Schwank, J.R.; Hughes, K.L.

    1991-01-01

    In this paper the radiation response of MOS devices exposed to 60 Co and low-energy (∼10 keV) x-ray irradiation is evaluated as a function of electric field during exposure. Improved charge yield estimates are obtained for 60 Co irradiations at fields below 1 MV/cm by matching voltage shifts due to oxide-trap and interface-trap charge to an E -0.55 electric field dependence. Combining these improved charge yield estimates and calculated dose enhancement factors, the relative response of x-ray to 60 Co irradiations is accurately predicted for oxide electric fields from 0.03 MV/cm to 5.0 MV/cm. The ability to predict the relative response of x-ray to 60 Co irradiations should speed acceptance of x-ray testers as a hardness assurance tool

  19. Health and ecological aspects of cobalt-60 transfer in seawater food chains typical of an intertidal mud-flat

    International Nuclear Information System (INIS)

    Amiard, J.C.; Amiard-Triquet, C.

    1977-01-01

    The assimilation and subsequent elimination of 60 Co by different marine organisms are affected by the mode of contamination: chronic or acute. Experimental 60 Co contamination of such organisms varies qualitatively and quantitatively according to whether the pollutant is transferred through the water or through the food. The concentration factor with respect to water, the transfer factor through food and the overall contamination estimate show a decrease for the highest trophic levels. (author)

  20. Seed germination of peanuts irradiated with cobalt ({sup 60}CO); Germinacao de sementes de amendoim irradiadas com cobalto ({sup 60}Co)

    Energy Technology Data Exchange (ETDEWEB)

    Alves, Niedja Marrize C.; Almeida, Francisco de Assis C.; Gomes, Josivanda P.; Pessoa, Elvira B., E-mail: niedjamarizze@yahoo.com.b, E-mail: josivanda@deag.ufcg.edu.b, E-mail: elvirabe@gmail.co [Universidade Federal de Campina Grande (UFCG), PB (Brazil). Dept. de Engenharia Agricola; Leal, Artur S. Cavalcanti, E-mail: arturcleal@yahoo.com.b [Universidade Federal de Campina Grande (UFCG), PB (Brazil). Dept. de Engenharia de Materiais

    2010-07-01

    This work was realized to evaluate the effect of gamma irradiation ({sup 60}Co) at doses 0, 0.50, 1.00, 1.50, 2.00, 2.50, 3.00 and 4.00 kGy, on germination of seeds of peanut, cultivar BR1. Irradiation Department of Nuclear, UFPE, where he received after the irradiation, they were stored in packing of PET and polyethylene braided with a time of 90 days. Through the results, obtained monthly, concluded that the dose of 0.5 kGy was effective in the germination of seeds of peanut, not affecting its power of germination and overcoming the witness within 30 to 60 days. (author)

  1. Beta- and gamma-decay studies of neutron-rich chromium, manganese, cobalt and nickel isotopes including the new isotopes 60Cr and 60gMn

    International Nuclear Information System (INIS)

    Bosch, U.; Schmidt-Ott, W.D.; Runte, E.; Tidemand-Petersson, P.; Koschel, P.; Meissner, F.; Kirchner, R.; Klepper, O.; Roeckl, E.; Rykaczewski, K.; Schardt, D.

    1987-10-01

    A 36 mg/cm 2 thick nat W target was irradiated with 11.5 MeV/u 76 Ge of 15 to 20 particle + nA beam intensity. On-line mass-separated samples of projectile-like neutron-rich products from multi-nucleon transfer-reactions were investigated in the region of mass 58-69 by β- and γ-ray spectroscopy. The new isotope 60 Cr was identified with a half-life of 0.57(6) s and for the 60 Mn ground-state a half-life value of 51(6) s was obtained. Decay schemes were constructed for 58 Cr, 58 Mn (t 1/2 = 3 s), 65,66,67 Co and 69 Ni. One new γ-ray was found in the decay of 59 Cr. The Q β -value of 66 Co was measured yielding 9.7(5) MeV. The comparison of the measured new β-half-life of 60 Cr with the most recent predictions gave again an enhancement of the experimental value. (orig.)

  2. Use of some inorganic and organic compounds as decontaminants for cobalt-60 and caesium-134 by clover plant grown on Inshas sandy soil

    Energy Technology Data Exchange (ETDEWEB)

    Abdel Sabour, M.F.; El-Naggar, H.A.; Soliman, S.M. (Atomic Energy Establishment, Cairo (Egypt). Nuclear Chemistry Dept.)

    1991-01-01

    Outdoor lysimeter experiments were carried out to elucidate the effect of 4 inorganic and 3 organic salts on {sup 60}Co and {sup 134}Cs uptake and dry matter yield of three cuts of clover in the soils of Inshas. A new concept was proposed for assessing the difference in capacity of soil to supply radionuclides to plants as affected by applied inorganic or organic compounds. A relation of plant tissue radionuclide content with time can be expressed in an exponential equation with corresponding regression coefficients. When the same plant species is grown on the same soil differing only in the applied compounds (e.g. Fe-EDDHA, Fe-DTPA, Fe-OAC, Fe(COO){sub 2}, Al(OH){sub 3}, Ca(H{sub 2}PO{sub 4}){sub 2}, Fe{sub 2}O{sub 3}) the derived equation will change. Differences of either Co or Cs accumulation with time between control and any other treatment were evaluated. The data also show that Fe-DTPA is preferred for {sup 60}Co as enhancing compound for plant uptake (for decontamination use), compared with other applied salts, on the other hand, any tested salts did not significantly effect {sup 134}Cs taken by clover. It was also found that more than 70% of the total cobalt uptake was accumulated in the roots which indicate that Co is less mobile in plants than Cs. (orig.).

  3. Use of some inorganic and organic compounds as decontaminants for cobalt-60 and caesium-134 by clover plant grown on Inshas sandy soil

    International Nuclear Information System (INIS)

    Abdel Sabour, M.F.; El-Naggar, H.A.; Soliman, S.M.

    1991-01-01

    Outdoor lysimeter experiments were carried out to elucidate the effect of 4 inorganic and 3 organic salts on 60 Co and 134 Cs uptake and dry matter yield of three cuts of clover in the soils of Inshas. A new concept was proposed for assessing the difference in capacity of soil to supply radionuclides to plants as affected by applied inorganic or organic compounds. A relation of plant tissue radionuclide content with time can be expressed in an exponential equation with corresponding regression coefficients. When the same plant species is grown on the same soil differing only in the applied compounds (e.g. Fe-EDDHA, Fe-DTPA, Fe-OAC, Fe(COO) 2 , Al(OH) 3 , Ca(H 2 PO 4 ) 2 , Fe 2 O 3 ) the derived equation will change. Differences of either Co or Cs accumulation with time between control and any other treatment were evaluated. The data also show that Fe-DTPA is preferred for 60 Co as enhancing compound for plant uptake (for decontamination use), compared with other applied salts, on the other hand, any tested salts did not significantly effect 134 Cs taken by clover. It was also found that more than 70% of the total cobalt uptake was accumulated in the roots which indicate that Co is less mobile in plants than Cs. (orig.) [de

  4. Use of inorganic and organic compounds as decontaminates for cobalt T-60 and cesium-134 by clover plant grown on Inshas Sandy soil

    International Nuclear Information System (INIS)

    Abdel-Sabour, M.F.; El-naggr, H.A.; Soliman, S.M.

    1994-01-01

    Out door lysimeter experiment was carried out to elucidate the effect of four inorganic and three organic salts on 60 Co and 134 Cs uptake and dry matter yield of three cuts of clover in the soil Inshas A new concept was proposed for assessing the difference in capacity of soil to supply radionuclides (i.e. 60 Co and 134 Cs) to plants as affected by applied inorganic or organic compounds. The relation of plant tissues (P c ) Co/IR Cs content with increasing time can be expressed as log (Pc) = A + B log time (T), where A and B the regression. When the same plant species is grown on the same soil differ only in the applied compound (e.g. Fe-EDDHA, Fe-DTPA, Fe-O A C, Fe(Coo)z, A1(OH)3, Ca(H2 P O 4 )2 and Fe 2 O 3 ) the equation will change to, log (P'c) = A + B' log (T) (I). Based on both equations, the relationship between (Pc) becomes; log (P'c) = [(A'B')/(A B + A B ) [ +[1/A'B + A B ) [ log (Pc) (II). The intercept (C) and slope (S) in Eq. (II) were determined among 7 treatments (for either 60 Co or 134 Cs). Then the difference of either Co or Cs accumulation with time between control and any other treatment was evaluated according to (C) and (S) values. The data also that Fe-DTPA is preferred for 60 Co as enhancing compound for plant uptake (for decontamination use); compared with other applied salts; on the other hand, any tested salts did not significantly effect 134 Cs taken by clover. Also, it was found that more than 70% of total cobalt uptake was accumulated in the roots which indicate that Co is less mobile in plants than Cs. 3 figs., 4 tabs

  5. Measurements of the light conversion efficiency of lithium borate for alpha particles relative to cobalt-60 gamma radiation

    Energy Technology Data Exchange (ETDEWEB)

    Bartlett, D.T.; Wall, B.F.; Fisher, E.S. (National Radiological Protection Board, Harwell (UK))

    1982-01-01

    The results are reported of measurements of the light conversion efficiencies of lithium borate TLD phosphor of British Nuclear Fuels Ltd. manufacture to 5.65 MeV and 2.4 MeV alpha particles relative to /sup 60/Co gamma radiation.

  6. Simulation of Groundwater Flow and Migration of the Radioactive Cobalt-60 from LAMA Nuclear Facility-Iraq

    Directory of Open Access Journals (Sweden)

    Thair Sharif Khayyun

    2018-02-01

    Full Text Available This study provides a simulation of groundwater flow and advective-dispersive migration of radioactive Co-60 through an aquifer with three layers, which release or leak to groundwater from the Active Metallurgy Testing Laboratory (LAMA Nuclear Facility-Iraq due to the nuclear accident scenario. Processing Modflow for windows (PMWIN and Modular Three-Dimensional Multispecies Transport (MT3DMS Models were used for this purpose. The study area and the contaminated area were 12.7 km2 and 0.005625 km2, respectively. Water levels of the groundwater have been measured in six monitoring wells. The simulation time was assumed to have started in 2016. The PMWIN model simulated the flow for two scenarios of water level in Tigris River (average and minimum water levels. The MT3DMS model simulated 10 years of plume travel, beginning in 2016. The simulated Co-60 concentrations after five years of travel were 32.34 and 34.44 μg/m3 for the two scenarios. The maximum predicted Co-60 concentrations at the end of Year 10 were 34.86 and 37.31 μg/m3, respectively. The sensitivity analysis showed that the simulated hydraulic heads in the observation wells and the simulated plume of Co-60 were highly sensitive to changes in the effective porosity but less sensitive to changes in other parameters of the dispersion and chemical reaction processes. The time necessary to reach steady state condition was predicted to be approximately 16 years. The contaminated area was isolated by using remedial process which is represented by three fully penetrating pumping wells with a suitable flow rate (0.045 m3/s for controlling the movement of Co-60 pollutant.

  7. The Accumulation and Retention of Zine-65 and Cobalt-60 by The Fresh Water Fish CLARIAS LAZERA

    International Nuclear Information System (INIS)

    Abdel Malik, W.E.Y.; Ibrahim, A.S.; Badawy, S.A.

    2003-01-01

    Some parameters affecting the accumulation and retention of 65 Zn and 60 Co radionuclides by the fresh water fish CLARIAS LAZERA from the contaminated filtered Ismail ia Canal water(FICW) have been investigated. It has been observed that the accumulated activity (KBq/g) increased with increasing exposure time with the contaminated FICW. This kind of bony fish has been shown to accumulate 65 Zn > 60 Co. The increase of the studied radionuclide carrier concentration in the canal water increased the fish uptake of both radionuclides. The increase of ph of the FICW decreased the accumulated activity by the fish. On the other hand, the retention of those radionuclides by this fish was investigated. It was possible from this study to give preliminary data for the calculation of the radiation dose that might be delivered to man eating the contaminated fish

  8. Experimental determination of gamma radiation effect from cobalt 60 on the viscosity of SSBR-B polymer

    International Nuclear Information System (INIS)

    Santos, L.G. dos; Silva Filho, E.

    1989-01-01

    Samples of the polymer known as SSBR-B (Solution Styrenne Butadiene Rubber-Blockade) were irradiated with gamma rays from a 60 Co source. Viscosity analysis performed by using the method of Ostwald Showed that the viscosity remains about constant for doses in the range of zero to 11560 Gray (Gy). For doses greater than 11560 Gy the viscosity increases. This result characterizes an irradiation induced hardening of the polymer. (author) [pt

  9. Dosimetric Comparison of Real-Time MRI-Guided Tri-Cobalt-60 Versus Linear Accelerator-Based Stereotactic Body Radiation Therapy Lung Cancer Plans.

    Science.gov (United States)

    Wojcieszynski, Andrzej P; Hill, Patrick M; Rosenberg, Stephen A; Hullett, Craig R; Labby, Zacariah E; Paliwal, Bhudatt; Geurts, Mark W; Bayliss, R Adam; Bayouth, John E; Harari, Paul M; Bassetti, Michael F; Baschnagel, Andrew M

    2017-06-01

    Magnetic resonance imaging-guided radiation therapy has entered clinical practice at several major treatment centers. Treatment of early-stage non-small cell lung cancer with stereotactic body radiation therapy is one potential application of this modality, as some form of respiratory motion management is important to address. We hypothesize that magnetic resonance imaging-guided tri-cobalt-60 radiation therapy can be used to generate clinically acceptable stereotactic body radiation therapy treatment plans. Here, we report on a dosimetric comparison between magnetic resonance imaging-guided radiation therapy plans and internal target volume-based plans utilizing volumetric-modulated arc therapy. Ten patients with early-stage non-small cell lung cancer who underwent radiation therapy planning and treatment were studied. Following 4-dimensional computed tomography, patient images were used to generate clinically deliverable plans. For volumetric-modulated arc therapy plans, the planning tumor volume was defined as an internal target volume + 0.5 cm. For magnetic resonance imaging-guided plans, a single mid-inspiratory cycle was used to define a gross tumor volume, then expanded 0.3 cm to the planning tumor volume. Treatment plan parameters were compared. Planning tumor volumes trended larger for volumetric-modulated arc therapy-based plans, with a mean planning tumor volume of 47.4 mL versus 24.8 mL for magnetic resonance imaging-guided plans ( P = .08). Clinically acceptable plans were achievable via both methods, with bilateral lung V20, 3.9% versus 4.8% ( P = .62). The volume of chest wall receiving greater than 30 Gy was also similar, 22.1 versus 19.8 mL ( P = .78), as were all other parameters commonly used for lung stereotactic body radiation therapy. The ratio of the 50% isodose volume to planning tumor volume was lower in volumetric-modulated arc therapy plans, 4.19 versus 10.0 ( P guided tri-cobalt-60 radiation therapy is capable of delivering lung high

  10. Copolymerization of Ethylene Induced by Cobalt-60 Gamma Radiation; Copolymerisation de l'ethylene induite par des rayons gamma du cobalt-60; Sopolimerizatsiya ehtilena pod dejstviem gamma-izlucheniya ot istochnika ks'yali-60; Copolimerizacion del etileno inducida por las radiaciones gamma del cobalto-60

    Energy Technology Data Exchange (ETDEWEB)

    Steinberg, M.; Colombo, P. [Brookhaven National Laboratory, Long Island, NY (United States)

    1963-11-15

    The gamma radiation initiated copolymerization of ethylene with a number of different monomers was studied at 20{sup o}C and initial pressures up to 680 atm. The experiments were conducted statically in two-phase systems with the exception of the ethylene-carbon monoxide system. Isolation of the copolymers was effected by solvent extraction and fractional precipitation techniques. Infra-red spectroscopy was used for identification. The composition was determined by elemental analysis. A partial evaluation of some of the reaction products including crystalline melting points, densities, solubility characteristics, and molecular weights are given. Evidence of ethylene copolymerization was established with each of the following monomers: styrene, methyl methacrylate, vinyl acetate, acrylonitrile, allyl acetate, isobutylene, chlorotrifluoroethylene, trans 2-butene, methyl acrylate, isoprene, propylene, vinyl chloride, 1-butene, cis 2-butene, carbon monoxide, vinyl pyrrolidone, methyl vinyl ketone, and divinyl benzene. The experimental data obtained in the study of the ethylene-carbon monoxide system were found to obey a linear form of the copolymer composition equation. The ratio of specific rate constants for carbon monoxide and ethylene ({alpha}) was found to have a value of 22.0, indicating that carbon monoxide as a monomer, is activated to the extent that it adds 22 times as fast as an ethylene monomer to an ethylene free-radical chain end. Explosive decomposition was observed to occur during irradiation of ethylene arid chlorotrifluoroethylene under certain irradiation conditions. There is an indication that a threshold radiation intensity exists which induces this violent reaction. The unique advantage of cobalt-60 gamma radiation is that it can be used to induce and control ethylene copolymerization reactions at low temperatures. (author) [French] La copolymerisation de l'ethylene avec divers monomeres provoquee avec des rayons gamma a ete etudiee a 20{sup o

  11. Viabilidade e micoflora de sementes de amendoim irradiadas com cobalto (60Co Viability and mycoflora of irradiated seeds of peanut with cobalt (60Co

    Directory of Open Access Journals (Sweden)

    Niédja M. C. Alves

    2011-03-01

    Full Text Available Estudou-se o efeito de diferentes doses da irradiação gama na germinação e percentagem de infecção fúngica em sementes de amendoim cultivar BR1. Inicialmente, as sementes foram avaliadas quanto à micoflora, utilizando-se o método de papel de filtro umedecido, a germinação em substrato de papel germitest e determinação do teor de umidade em estufa, a 105 ± 2 ºC. Posteriormente, as sementes foram submetidas à irradiação com uma fonte de 60Co, tipo gammacell, onde se estudou o efeito de 8 doses de irradiação na micoflora e germinação das sementes acondicionadas em embalagem de PET e polietileno trançado durante 60 dias de armazenamento, sem controle de temperatura e umidade relativa do ar. Os fatores estudados (doses em kGy, embalagens e tempo de armazenamento foram analisados em um delineamento inteiramente casualizado, dispostos em fatorial. Com base nos resultados, observou-se que a irradiação gama afetou negativamente a germinação das sementes de amendoim e que doses acima de 3,0 kGy comprometem a germinação das sementes. A radiação a partir da dose 1,5 kGy eliminou os fungos Aspergillus niger e, Penicillium a partir da dose de 2,5 kGy.The effect of different doses of the gamma irradiation was studied on germination and percentage of fungal infection in peanut seeds cultivar BR1. Initially the seeds were evaluated for the mycoflora using the method of humidified filter paper, the germination in paper substratum germitest and determination of the moisture content in oven at 105 ± 2 ºC. Later on the seeds were submitted to irradiation with a source of 60Co, type gammacell, where the effect was studied of 8 doses of irradiation in the mycoflora and germination of the seeds conditioned in PET packing and polyethylene tressed during 60 days of storage, without control of temperature and relative humidity of the air. The studied factors (doses in kGy, packing and time of storage were analyzed in a completely

  12. Sensory evaluation of black beans submitted to gamma radiation from Cobalt-60; Avaliacao sensorial de feijao preto submetido a radiacao de Cobalto-60

    Energy Technology Data Exchange (ETDEWEB)

    Moura, Neila Camargo de; Canniatti-Brazaca, Solange Guidolin; Spoto, Marta Helena Fillet, E-mail: sgcbraza@esalq.usp.b [Escola Superior de Agricultura Luiz de Queiroz (ESALQ/USP), Piracicaba, SP (Brazil). Dept. de Agroindustria, Alimentos e Nutricao; Arthur, Valter [Centro de Energia Nuclear na Agricultura (CENA/USP), Piracicaba, SP (Brazil). Secao de Entomologia e Irradiacao de Alimentos

    2005-04-15

    The objective of this research was to evaluate the sensory aspects of black beans submitted to gamma radiation from {sup 60}Co. The study involved eight panelists, between 17 to 23 years old, who were selected and trained for the descriptive analysis of appearance, aroma, flavor and texture. The panelists analyzed alterations of appearance, aroma, flavor and texture of non-irradiated and irradiated black beans with doses 2, 4, 6, 8 and 10kGy. The results were analyzed by test F, ANOVA and the Tukey test (5%), with the use of computers and the sensory analysis software Compusense Five and SAS. The results showed that irradiated samples decreased the bitter flavor, accentuated color and brightness and samples non-irradiated dry texture. The radiation treatment is a good method for conservation of black beans in doses evaluated in this study.(author)

  13. The Effects of Cobalt-60 Gamma Radiation on Vitamin B{sub 6} and Folic Acid; Effets des rayons gamma (cobalt-60) sur la vitamine B{sub 6} et l’acide folique

    Energy Technology Data Exchange (ETDEWEB)

    Galatzeanu, I.; Antoni, F. [International Atomic Energy Agency, Vienna (Austria)

    1967-09-15

    A study has been made of the behaviour of pyridoxine and folic acid, including structural changes, after {sup 60}Co gamma irradiation. The irradiation of pyridoxine (vitamin B{sub 6}) and folic acid in aqueous solutions leads to their partial or total destruction, depending on the dose. The irradiation of pyridoxine and folic acid in the solid state mainly results in the elimination of hydrogen atoms (free radicals). After dissolving the irradiated samples in acid solutions it was observed that the irradiated molecule was renewed through replacement of the eliminated hydrogen atoms, which depend on the pH-value of the solution. This gives the possibility of sterilizing both pyridoxine and folic acid in the solid state by irradiation at 2 Mrad. Most of the radiolysis products of pyridoxine and folic acid irradiated in solution and in the solid state have been separated and identified by means of chromatography (paper and thin layer) and cellulose column electrophoresis. Electron spin resonance was used to determine the concentration and nature of the free radicals after irradiation of pyridoxine and folic acid in the solid state. (author) [French] On a Studie le comportement de la pyridoxine et de l'acide folique apres exposition aux rayons gamma ({sup 60}Co) et les changements dans leurs structures. L'irradiation de la pyridoxine (Vitamine B{sub 6}) et de l'acide folique en solutions aqueuses enttarne leur destruction partielle ou totale selon la dose. L'irradiation de la pyridoxine et de l'acide folique á l'etat solide enttarne principalement l'elimination d'atomes d'hydrogene (radicaux libres). Par dissolution des echanrilions irradies dans des solutions acides, on a observe un renouvellement de la molecule irradiee par remplacement des atomes d'hydrogene elimines qui est fonction du pH de la solution, ce qui permet de radiosteriliser a 2 Mrad á l'etat solide tant la pyridoxine que l'acide folique. On a separe et identifie la majorite des produits de radiolyse

  14. Hippophae leaf extract (SBL-1) countered radiation induced dysbiosis in jejunum of total body 60Cobalt gamma - irradiated mice

    International Nuclear Information System (INIS)

    Beniwal, C.S.; Madhu Bala

    2014-01-01

    Single dose of SBL-1 administered at the rate 30 mg/kg body weight (b.w.) 30 min prior to whole body 60 Co-gamma-irradiation at lethal dose (10 Gy), rendered >90% survival in comparison to zero survival in the non-SBL-1 treated 60 Co-gamma-irradiated (10 Gy) mice population (J Herbs Spices Med Plants, 2009; 15(2): 203-215). Present study investigated the effect of SBL-1 on jejunal microbiota in lethally irradiated mice. Study was performed with inbred Swiss albino Strain 'A' male mice (age 9 weeks) weighing 28±2 g. The animals were maintained under controlled environment at 26±2℃; 12 h light/dark cycle and offered standard animal food (Golden feed, Delhi) as well as tap water ad libitum. Metagenomic DNA was extracted, purified and quantified from jejunum of the mice. Universal primers (27f and 1492r) were used to amplify the 16S rRNA DNA from the metagenomic DNA. Amplicons were sequenced, vector contamination and chimeras were removed. The sequences (GenBank Accession No: KF681283 to KF681351) were taxonomically classified by using Sequence Match program, Ribosomal Database Project as well as by nucleotide-BLAST (E-value: 10, database: 16S rRNA gene sequences, Bacteria and Archea). Phylogenetic Tree was prepared using MEGA 5.2 package, using maximum likelihood algorithm after sequence alignment by MUSCLE. Thermus aquaticus was used as out-group to construct rooted tree. Branch stability was assessed by bootstrap analysis. Untreated animals and the animals treated with SBL-1 had 100% Lactobacillus; 60 Co gamma-irradiated animals had 55% Cohaesibacter (Alphaproteobacteria); 27% Mycoplasma (Tenericutes) and only 18% Lactobacillus; animals treated with SBL-1 prior to irradiation had 89% Lactobacillus and 11% Clostridium. This study demonstrated that treatment with SBL-1 at radioprotective doses before total body irradiation with lethal dose (10 Gy) countered the jejunal dysbiosis. (author)

  15. Calculation of cobalt-60 primary and scatter dose in layered heterogeneous phantoms using primary and scatter dose spread arrays

    International Nuclear Information System (INIS)

    Iwasaki, Akira

    1993-01-01

    A method of making 60 Co γ-ray primary and scatter dose spread arrays in water is described. The primary dose spread array is made using forward and backward primary dose spread equations (h 1 and h 2 ), where both equations contain a laterally spread primary dose equation (G), made from measured dose data in a cork phantom. The scatter dose spread array is made using differential scatter-maximum ratio (dSMR) and differential backscatter factor (dBSF) equations (k 1 and k 2 ), where both equations are made to be continuous on the boundary. Primary and scatter dose calculations are performed along the beam axis in layered cork heterogeneous phantoms. It is found, even for 60 Co γ-rays, that when a small tumor in the lung is irradiated with a field that just surrounds the tumor, the beam entrance surface and lateral side of the tumor may obtain no therapeutic dose, because of loss of longitudinal and lateral electronic equilibrium, and when a large tumor in the lung is irradiated with a field just surrounding the tumor, the lateral side of the tumor may obtain no therapeutic dose due to loss of lateral electronic equilibrium. (author)

  16. Quarantine treatment in eggs of Stenoma catenifer Walsingham (Lepidoptera: Elachistidae), with gamma radiation of Cobalt-60; Tratamento quarentenário em ovos de Stenoma catenifer Walsingham (Lepidoptera: Elachistidae), com radiação gama do Cobalto-60

    Energy Technology Data Exchange (ETDEWEB)

    Silva, L. K.F.; Arthur, V.; Nava, D. E.; Parra, J. R.P.

    2006-10-15

    The objective of this work has been to determine the lethal dose of gamma radiation of Cobalt-60 for the Stenoma catenifer eggs. For the irradiation of the eggs an irradiador Gammacell-220 (CO60) was utilized, (Rate dose: 1.054 kGY/h). The doses were: 0, 25, 50, 75, 100, 125 and 150 Gy, 90 eggs/dose (six repetitions). The number of caterpillars emerged was evaluated, and the survivors growed in seeds of avocado. The adults obtained were coupled with normal insects, growed in boxes with double face paper containing the food (10% honey) and a fruit of avocado. The experimental design was totally random, being the data submitted to the analysis of the varianza and the averages compared by the test of Tukey (P=5%). The emergence of caterpillars from the treated eggs with dose of 0, 25 and 50 Gy was verified. The dose of 50 Gy caused deformation in the caterpillars emerged. The effect of the gamma radiation in the viability of the eggs was proportional to the dose increase. The adults from the eggs dealt with 25 Gy presented non viabilty of 92,85 and 100% for male and female, respectively. A radiation gamma of 75 Gy is recommended for treatment quarantine for avocado fruits infested with of S. catenifer eggs.

  17. Exemption from licensing requirements for spark-gap irradiators that contain cobalt-60: (Docket No. PRM 30-54): Draft environmental statement

    International Nuclear Information System (INIS)

    1975-09-01

    This Draft Statement on environmental considerations associated with the proposed exemption of cobalt-60 in spark-gap irradiators was prepared by the US Nuclear Regulatory Commission, Office of Standards Development (the staff), in accordance with the Commission's regulation 10 CFR Part 51, which implements the requirements of the National Environmental Policy Act of 1969 (NEPA). The NEPA states, among other things, that the federal government has the continuing responsibility to use all practicable means, consistent with other essential considerations of national policy, to improve and to coordinate federal plans, functions, programs, and resources to the end that the nation may: fulfill the responsibilities of each generation as trustee of the environment for succeeding generations; assure for all Americans safe, healthful, productive, and esthetically and culturally pleasing surroundings; attain the widest range of beneficial uses of the environment without degradation, risk to health or safety, or other undesirable and unintended consequences; preserve important historic, cultural, and natural aspects of our national heritage, and maintain, wherever possible, an environment which supports diversity and variety of individual choice; achieve a balance between population and resource use which will permit high standards of living and a wide sharing of life's amenities; and enhance the quality of renewable resources and approach the maximum attainable recycling of depletable resources. 42 refs., 5 figs., 7 tabs

  18. Use of low doses of cobalt 60 gamma radiation on beet (Beta vulgaris L.), carrot (Daucus carota L.) and radish (Raphanus sativus L.) seed to stimulate increase yield

    International Nuclear Information System (INIS)

    Bovi, Jose Eduardo

    2000-01-01

    The research had the aim of evaluating the effects of low doses of Cobalt-60 gamma radiation on seeds of radish (Raphanus sativus L.) cultiva Champion, cultivars Nantes Forto (european origin) and Brasilia (Rio Grande do Sul origin) carrot (Daucus carota L. var. sativus (Hoffm.) Thell), and red beet (Beta vulgaris L.) cultivar Tall Top Early Wonder before sowing, its effects on plant growth, on the yield and roots storage of two tillages: with sowing in the same day of radiation and six days after radiation seeds. The data showed that the seeds radiation did not interfered negatively on plants growth, and the species presented differences as roots production and doses on both plantation: radish with 5,0 Gy and 2,5 Gy doses respectively to the first and the second sowings, Brasilia carrot with 2,5 Gy dose to both sowings. Nantes carrot with 2,5 Gy and 5,0 Gy respectively to the first and the second sowings, and beet with 7,5 Gy and 5,0 Gy respectively to the first and the second plantations. There is not statistics difference by Tukey test (5% and 1%) and none relation between seeds radiation and loss weight on roots storage. (author)

  19. Preliminary study on the effect of cobalt-60 gamma radiation on the conservation of potato tubers for consumption (Solanum tuberosum l.), during the storage period

    International Nuclear Information System (INIS)

    Montepeque Roldan, R.

    1984-03-01

    The object of the thesis is the study of the inhibiting effect of the sprouting of potato tubers, variety Loman, after Cobalt-60 gamma irradiation (with doses of 4, 6, 8, 10 and 12 Krads) as well as after treatment with the chemical inhibitor Isopropyl-N-Phenyl Carbonate (IPC). These treatments were applied to different groups of tubers, after 15 and 45 days from harvesting, stored under two illumination conditions: darkness (closed room), and indirect light (straw hut). The number, length and thickness of the sprouts, as well as the weight, humidity contents and infection of the tubers were recorded twice a month. A random 2x2x7x4 multifactorial design, with 3 repetitions, was used for the analysis and interpretation of the results. Variance and multiple regression analysis, as well as Tukey tests were performed on the IBM/370 computer of the San Carlos University (Guatemala). It was found that both the 4 and 6 Krad doses and the IPC treatments have no effect on the sprouting inhibition. The irradiation with the 8, 10, and 12 Krad doses inhibited the sprouting in an irreversible way, with insignificant loss of weight and moisture, regardless of the irradiation epoch and light condition. However, the tubers stored in darkness, showed ideal characteristics for consumption, and the 8 Krad dose, applied at 15 days after harvesting is concluded to be the best

  20. Use of gamma radiation of Cobalt-60 aiming at the quarentenary treatment and the sterilization of Stenoma catenifer Walsingham (Lepidoptera: Elachistidae)

    International Nuclear Information System (INIS)

    Silva, L.K.F.; Arthur, V.; Nava, D.E.; Parra, J.R.P.

    2007-01-01

    The objective of this work was verify the influence of gamma radiation of Cobalt-60, in the avocado moth Stenoma catenifer Walsingham (Lepidoptera: Elachistidae). For this research, insects were irradiated in all phases of their life cycle with doses varying from 0 to 600 Gy and they were maintained at the temperature of 25 +/- 2 deg C, relative humidity of 70 +/- 10% and photofase of 14 h. The species was reared on natural diet, avocado seeds, variety Breda. According to the obtained results, was verified that the lethal dose of gamma radiation to S. catenifer larvae and pupae was of 300 Gy. The sterile dose for upcoming adults from irradiated S. catenifer larvae, was of 100 Gy; for adults coming from irradiated pupas was of 150 Gy and for irradiated adults was of 200 Gy. The use the gamma radiation as treatment quarentine of S. catenifer was efficient, should be treated them with doses able to promote the sterilization of insect, without committing your qualities physical-chemistries and sensorial of fruits. Therefore, is suggested the treatment with the dose of 50 Gy for fruits infested with eggs and 150 Gy for fruits infested with larvae and pupas of S. catenifer. For use the sterile insect technique is recommended the irradiation of pupas and adults with doses of 150 Gy and 200 Gy, respectively [pt

  1. Development of a new model of actinic enteritis in rats using a cobalt-60 open source and a protection device as a collimator

    Energy Technology Data Exchange (ETDEWEB)

    Nunes, Vinicius Rodrigues Taranto; Vidigal, Paula Vieira Teixeira; Barbuto, Rafael Calvao; Duval-Araujo, Ivana, E-mail: vivas1912@hotmail.com [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte (UFMG), MG (Brazil); Pereira, Marcio Tadeu; Ladeira, Luis Carlos Duarte [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil)

    2017-03-15

    Purpose: To describe a new model of actinic enteritis that does not use radiotherapy machines. Methods: Sixteen Wistar rats were divided into four groups, consisting of four animals each: control (group A), two weeks after irradiation (group B), five weeks after irradiation (group C) and eight weeks after irradiation (group D). Animals were given a 10Gy radiation from a Cobalt-60 natural source in a nuclear technology research center. Protections of the surrounding tissues were obtained through the usage of plumb devices with a hole in the center, which served as a collimator. We obtained irradiated and non-irradiated colons from each animal. Results: In group B we found an important inflammatory response in the irradiated colon, which appeared in a reduced way in group C and was minimal in group D, in which we found a relevant collagen submucosal deposition/fibrosis. In all groups, the non-irradiated colon had a lower pathological damage in comparison with the irradiated colon. Conclusion: We thus described an efficient and feasible technique for obtaining an animal model of actinic enteritis. (author)

  2. Humoral response and neutralization capacity of sheep serum inoculated with natural and Cobalt 60-irradiated Crotalus durissus terrificus venom (Laurenti, 1768)

    International Nuclear Information System (INIS)

    Netto, D.P.; Alfieri, A.A.; Chiacchio, S.B.; Bicudo, P.L.; Nascimento, N.

    2002-01-01

    The aim of this work was to investigate antigen irradiation on crotalic antivenom and the capacity of sheep as serum producers. Twelve sheep in two groups of six were inoculated with Crotalus durissus terrificus venom. One group was inoculated with natural venom (N V) and the other with Cobalt 60 gamma-irradiated venom (Ir V). Three antigen doses were given to the animals at monthly intervals for immunization. The toxic activity of the venom was assessed by LD 50 determination in mice. Blood samples were collected weekly analyses of serum neutralization capacity and potency. At the end of the experiment, the animals were challenged with a LD 50 for sheep showed no signs of envenoming. These results showed that toxicity of the irradiated venom was 4.4 times less than the natural venom. The sera from the irradiated group neutralized LD 50 14.6 times, and the sera from the natural group 4.4 times. Sera from the irradiated group were five times more potent. The two groups did not present clinical alterations. The results of this study show the potential for using sheep in crotalic antivenom production. The use of irradiated venom in sheep immunization induces a powerful and lasting humoral immune response shown by both the in vitro neutralization and potency tests and by the indirect ELISA antibody level detection technique. (author)

  3. A Modified Design for the Eastern Radiation Canyon for Cobalt60 Irradiator Maintain Attachment For Research and Production

    International Nuclear Information System (INIS)

    Keshk, A.B.; Ashour, M.A.; Imam, M.M.

    2003-01-01

    About 160 industrial radiation facilities using Co 60 are currently in operation in about 45 countries, many of them in developing countries. Most of these facilities are used for sterilization of medical products and pharmaceuticals, with a small number being used for processing of food items. The total installed capacity for processing of medical products at 20-25 k.Gy is about one million ton annually. There is a need to make some modifications on the design of these radiation canyons to allow radiation research, during mass production. By designing a new track for experimental research which can pass inside and outside radiation canyon through a special maze (labyrinth). The research samples will be put in two boxes out side the research door and they will go inside the canyon through research maze and stopped behind the products cars on two position, facing the source rack which will be in radiation position. The boxes will return back after finishing the exposure period

  4. Effects of cobalt-60 gamma radiation on the strength-related internal structure of the borosilicate glass

    International Nuclear Information System (INIS)

    Cafe, Arven I.; Liamzon, Angelie J.

    2011-03-01

    Borosilicate glass in the form of glass slides (1.Omm in thickness and cut into 12.5mm x 55.Omm surface area) was examined to determine the reusability or recyclability and strength of glass apparatuses or compartments after exposing to gamma irradiation from Co-60 source. After knowing the initial parameters using EDXRF under six secondary targets, glass specimens prepared was subjected to gamma radiation for doses 3kGy, 6kGy, 15kGy, 25kGy, and 100kGy. Results of characterization under FTIR provides information about the occurred extension of B-O-Si and B-O-B linkages for lower doses (3-25kGy), while destruction of Si-O bonds for higher dose (100kGy). It shows direct relationship on the observed color change from clear ransparent to deep brown corresponding to the change in optical densities as irradiation dose increases. Ability to fade the induced deep brown color was also observed for a certain time interval which satisfies that this type of glass exhibits self healing property. Although, average energy of about 1.25MeV causes rearrangement of atoms within the glass, according to the XRD result, it remained to be an amorphous solid even in higher dose applied which satisfies that remanufacturing and recycling is possible. (author)

  5. The use of apoptosis in human lymphocytes peripheral as alternative methods in biological dosimetry of radiation effects from cobalt-60

    International Nuclear Information System (INIS)

    Lemes, Marisa

    1997-01-01

    Gamma rays affect cells in dose-response manner, resulting in cell death, as in cancer radiotherapy. The ionizing radiation acts by transferring energy, mainly by free radicals from water radiolysis that result in nucleic acid damage and other effects in lipids and proteins, The level of exposure is indirectly estimated by physical dosimetry, but the biological dosimetry can measure the direct radiation effect, mainly in post-dividing cells by classical cytogenetic approach. Recently, it was reported that irradiated cells develop an induced programmed death or apoptosis. With a biological dosimetric technique, we measured apoptotic cell fraction in 60 Co in vitro irradiated blood cells from voluntary healthy donors. The agarose gel electrophoresis showed a low sensitivity, because cell DNA presented the characteristic pattern only when the cells were exposed to 100 c Gy or more. Using a terminal DNA labeling technique we observed that the apoptotic cell fraction proportionally increases with irradiation. Similar sensitivity was observed when compared to classical cytogenetics (3 c Gy minimum detection level). These techniques are easier to perform, do not need cell culture and all cells, including interphase ones, can be analyzed, providing a good tool in biological dosimetry. (author)

  6. Thermoluminescence characteristics of Cu2O doped Calcium Lithium borate glass irradiated with the cobalt-60 gamma rays

    International Nuclear Information System (INIS)

    Rammadhan, Ismail; Taha, Saddon; Wagiran, H.

    2017-01-01

    The aim of this study is to prepare and investigate the thermoluminescence characteristics for the un-doped and Cu 2 O doped calcium lithium borate glass upon adding various Cu 2 O concentrations of 0.005% to 0.1 mol%. The glasses were prepared by melt quenching method and irradiated with 60 CO gamma-ray having different doses in the range of (0.5–4) Gy, (5–10) Gy, and (20–100) Gy. The amorphous phases were identified for optimization glass samples, effect of heating rate, glowing curves, linearity, sensitivity, fading, reproducibility of response and minimum detectable dose are also studied. The TL sample with 0.02 mol% Cu 2 O concentration has higher response compared to the other samples concentration for a delivered dose of 50 Gy, The recorded glow curves consist a dominant peak at 187 °C for a heating rate of 5 °C s −1 . However, the value of effective atomic number Z eff is 8.84 for 0.02Cu 2 O doped which are near to the atomic number of soft tissue. - Highlights: •We have prepared and investigate the crystalline structure for the un-doped and Cu 2 O doped calcium lithium borate glass are carried out. •Investigate the amorphous structure of calcium lithium borate glass. •Determine the best setting of annealing temperature, annealing time and heating rate for Cu 2 O doped calcium lithium borate glass. •The doping effects of Cu 2 O on the thermoluminescence properties of calcium lithium borate glass subjected gamma radiations. •The new dosimeter showed simple glow curve with single prominent peak centred at 187 °C and linear dose–response range 0.5–100 Gy, good reproducibility, the fading of the signal is relatively slow. •Effective atomic number for Cu 2 O doped Calcium lithium borate close to the effective atomic number of soft tissue.

  7. Thermoluminescence characteristics of Cu{sub 2}O doped Calcium Lithium borate glass irradiated with the cobalt-60 gamma rays

    Energy Technology Data Exchange (ETDEWEB)

    Rammadhan, Ismail, E-mail: ismail.rammadhan@koyauniversity.org [Department of Physics, Universiti Teknologi Malaysia, 81310 Skudai, Johor (Malaysia); Department of Physics, Faculty of Sciences and Health, Koya University, Danielle Mitterrand Boulevard, Koya 45, Kurdistan Region (Iraq); Taha, Saddon [Department of Physics, Faculty of Sciences and Health, Koya University, Danielle Mitterrand Boulevard, Koya 45, Kurdistan Region (Iraq); Wagiran, H. [Department of Physics, Universiti Teknologi Malaysia, 81310 Skudai, Johor (Malaysia)

    2017-06-15

    The aim of this study is to prepare and investigate the thermoluminescence characteristics for the un-doped and Cu{sub 2}O doped calcium lithium borate glass upon adding various Cu{sub 2}O concentrations of 0.005% to 0.1 mol%. The glasses were prepared by melt quenching method and irradiated with {sup 60}CO gamma-ray having different doses in the range of (0.5–4) Gy, (5–10) Gy, and (20–100) Gy. The amorphous phases were identified for optimization glass samples, effect of heating rate, glowing curves, linearity, sensitivity, fading, reproducibility of response and minimum detectable dose are also studied. The TL sample with 0.02 mol% Cu{sub 2}O concentration has higher response compared to the other samples concentration for a delivered dose of 50 Gy, The recorded glow curves consist a dominant peak at 187 °C for a heating rate of 5 °C s{sup −1}. However, the value of effective atomic number Z{sub eff} is 8.84 for 0.02Cu{sub 2}O doped which are near to the atomic number of soft tissue. - Highlights: •We have prepared and investigate the crystalline structure for the un-doped and Cu{sub 2}O doped calcium lithium borate glass are carried out. •Investigate the amorphous structure of calcium lithium borate glass. •Determine the best setting of annealing temperature, annealing time and heating rate for Cu{sub 2}O doped calcium lithium borate glass. •The doping effects of Cu{sub 2}O on the thermoluminescence properties of calcium lithium borate glass subjected gamma radiations. •The new dosimeter showed simple glow curve with single prominent peak centred at 187 °C and linear dose–response range 0.5–100 Gy, good reproducibility, the fading of the signal is relatively slow. •Effective atomic number for Cu{sub 2}O doped Calcium lithium borate close to the effective atomic number of soft tissue.

  8. Application gamma radiation of cobalt-60 in disinfestation of some types of rations for feeding small animals

    International Nuclear Information System (INIS)

    Arthur, Paula Bergamin

    2012-01-01

    The pests as beetles, mites, moths and mushrooms among other, usually infest products stored as: grains, crumbs, flours, coffee, tobacco, dried fruits, animal rations, spices, dehydrated plants, causing the visual depreciation and promoting to deterioration of the products. The present research had as objective the use of the gamma radiation in the disinfestation of some types of rations used for feeding animals of small size. In the first experiment packing of free samples were used measuring 10 cm x 20 cm with capacity of 70 grams of substrate (ration) with 4 types of existent marks in the trade: (1), (2), e (3), and (4). Each treatment consisted of 10 repetitions, that were irradiated with doses of: 0 (control) 0,5; 1,0 and 2,0 kGy, to do the disinfestation of the samples. After the irradiation (disinfestation) of the all irradiated packing and more the control was conditioned in plastic boxes of 80 cm x 50 cm with cover, where the insects were liberated Lasioderma serricorne, Plodia interpuctella, Sitophilus zeamais and Sitophilus oryzae, in a total of 400 for each box and maintained at room acclimatized with 27 ± 2 Deg C and relative humidity of 70 ± 5%. In the second experiment packing were used made with the materials of packing of the first experiment. Each packing was made of 10 cm x 15 cm, with capacity of 30 grams of substrate (ration). In each repetition was inoculated 10 insects of each species, in a total of 400 insects for experiment per box. The packing with substrate and insect, were stamped in commercial machine and irradiated with doses of: 0 (control) 0,5; 1,0 and 2,0 kGy. The irradiated packing and the control were maintained at room acclimatized same the mentioned in the first experiment. The counting of the number of insects and holes in the packing were made after 60 days. Concluded that only the packing of the ration type number 4 was susceptive to attack of all species of insects. The dose of 0,5 kGy was sufficient to induce the

  9. The Co{sup 60} Irradiation Facility and the Gamma Field at Riso; Appareil d'irradiation au cobalt-60 et champ sous irradiation gamma, a Riso; Ustanovka dlya obluchenij, rabotayushchaya na So60, i pole gamma-luchej v rizo; Instalacion de irradiacion con cobalto-60 y campo de irradiacion gamma en el centro de Riso

    Energy Technology Data Exchange (ETDEWEB)

    Brynjolfsson, A; Holm, N W [Danish Atomic Energy Commission, Establishment Riso (Denmark)

    1960-07-15

    The paper describes both the Co{sup 60} irradiation facility and the gamma field at the Agricultural Department of the Research Establishment, Riso. The Co{sup 60} irradiation facility contains 1,800 curies of Co{sup 60.} Details of the construction are given together with the safety precautions which have been included in the design. Dosimetry has been carried out by four different methods: 1. Ionisation chambers, 2. Calorimetry, 3. Fricke dosimeter, 4. Photographic films. A general outline is given of the gamma field, including details of source position. The dose rate is approximately 100 r./hr. at a distance of 1 m. An area of radius 15 m is used for the growing of plants under irradiation. A brief indication is given of the class of products which have been irradiated in the two facilities. (author) [French] Le memoire decrit l'appareil d'irradiation au cobalt-60 et le champ sous irradiation gamma du Departement de l'agriculture de l'Organisme de recherche de Riso. L'appareil d'irradiation au cobalt-60 contient une source de 1 800 curies. Des details sont donnes sur la construction ainsi que sur les dispositifs de protection compris dans le plan. Quatre methodes differentes ont ete utilisees pour la dosimetrie: 1. Chambres d'ionisation 2. Calorimetrie 3. Dosimetrie de Fricke 4. Pellicules photographique s On donne un apercu general du champ gamma, ainsi que des details sur la position de la source. L'intensite de dose est de 100 R/h environ a une distance de 1 m. Une zone d'un rayon de 15 m est utilisee pour la croissance des plantes soumises a l'irradiation. Des indications sommaires sont donnees sur la categorie des produits qui ont ete soumis a l'irradiation dans les deux installations. (author) [Spanish] Los autores describen la instalacion de irradiacion con cobalto-60 y el campo de irradiacion gamma del Departamento de Agronomia del Instituto de Investigaciones de Riso. El dispositivo de irradiacion consiste en una fuente de cobalto-60 de 1 800 curies

  10. Use of gamma radiation cobalt 60 for disinfestation of Lasioderma serricorne (Fabricius, 1972) (Coleoptera: Anobiidae) in Chamomilla recutita L. and Pimpinela anisum L. dehydrated

    International Nuclear Information System (INIS)

    Alves, Juliana Nazare; Potenza, Marcos Roberto

    2008-01-01

    Stores products such a grains, flours, dry fruits and spices are normally infested by pests as beetles (Lasioderma serricorne), mites and moths, depreciating the product visually and promoting its deterioration. To improve the quality of spices, medicinal plants and others foodstuffs there is a need for adequate methods of handling, correct identification of the species, adequate collection and storage. The objective of this work was to determine the dose of gamma radiation for the disinfestation of medicinal and aromatic plants infested by L. serricorne. The plants used in this study were Chamomilla recutita L. and Pimpinela anisum L. in this dehydrated form. The experiment was carried out in the Laboratorio de Inseticidas e Acaricidas from Instituto Biologico/SP, during the months of January and May 2006, and the irradiations were carried out in the Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN/SP, using and experimental Cobalt 60 irradiator, model Gammacell 220. Each treatment consisted of 5 parcels containing 10 g of dehydrated products infested with 20 last instar larvae of L. serricorne, conditioned in plastic 10 x 10 cm containers with small punctures in the cover to allow internal aeration. The substratum previously infested was submitted to increasing doses of gamma radiation: 0: 0.5; 0.75; 1.0; 1.25; 1.50; 1.75; 2.0; 2.25; 2.50 and 2.75 kGy. After irradiation, the samples were kept in a acclimatized room at 27 ± 2 deg C of temperature and relative humidity of 70 ± 5% and after a 45 days period the number of adults insects emerged was evaluated. The disinfestation dose of gamma radiation for last instar larvae L. serricorne on Chamomilla recutita L. and Pimpinela anisum L. was 2.0 kGy. (author)

  11. High levels of stable p53 protein and the expression of c-myc in cultured human epithelial tissue after cobalt-60 irradiation

    International Nuclear Information System (INIS)

    Mothersill, C.; Seymour, C.B.; Harney, J.; Hennessy, T.P.

    1994-01-01

    When explants of human uroepithelium or esophageal epithelium are exposed to acute doses of radiation (cobalt-60), the cells which grow out to form the primary cultures show a number of abnormal features. These include the development of characteristic nonsenescent foci. These foci have previously been shown to be c-myc positive and to have an abnormal, tumor-like ultrastructure. Expression of c-myc and the level of stable p53 proteins have now been examined in these cultures 2 weeks after irradiation. Both proteins occurred in dividing cells at the growing edge of the explant and in the foci. The expression of c-myc appeared to be correlated with growth. As expected, variation between individual cultures of normal human cells was noted in the expression of stable p53 protein. Most control uroepithelial cell cultures were negative, but a small cohort showed a wide range of values. The control cultures from the esophageal tissues had high expression of p53, and this decreased marginally after irradiation. Cells positive for p53 were always in cycle and were usually positive for c-myc as well. It would appear from these results that the expression of c-myc and the stable form of the p53 protein occur in irradiated primary cultures of normal human cells both in foci which also express a number of abnormalities and in open-quotes edgeclose quotes cells which are dividing. Cultures of unirradiated cells from esophagus and a small number of uroepithelial samples had high levels of p53. Possible reasons for this are discussed. 33 refs., 2 figs., 3 tabs

  12. The justification for the use of table of equivalent squares with respect to reference depth total scatter factor, and phantom scatter factor, for cobalt-60 teletherapy

    International Nuclear Information System (INIS)

    Afari, F.

    2011-01-01

    The use of equivalent squares is of great value and importance when determining output and depth dose data for rectangular fields. The variation with field shape of collimator scatter factors (S c ), phantom scatter factors (S c,p ) were studied using measurements on GWGP 80 cobalt - 60 teletherapy machine at the National Centre of Radiotherapy and Nuclear Medicine in the Korle-Bu Teaching Hospital. Measurements of the collimator scatter factors (S c ), phantom scatter factors (S p ) and total scatter factors (S c, p) were made at the depth of 5 cm, 10 cm, 15 cm and 20 cm in full scatter water phantom for square field side and rectangular fields of varying dimensions. The measurements were done using the source - axis distance (Sad) technique. The values of total scatter factor (S c,p ), phantom scatter factor and collimator scatter factor (S c ) obtained were used to estimate equivalent squares for the rectangular fields at the various depths. The equivalent squares were computed using the method of interpolation which is based on the scatter analysis of these scatter factors and these estimated equivalent squares were then compared with equivalent squares were then compared with equivalent square fields from BJR (supplement 21) tables of equivalent squares. The research revealed that there were average deviation of 1.5% for smaller rectangular field sizes and 8.8% for elongated rectangular field sizes between the estimated square field sizes and the equivalent square field from BJR (supplement 21) Table of equivalent square fields. The 8.8% for the elongated rectangular fields is not accepted, though such fields are rarely used in our Hospitals. It was found that the values of the equivalent square at the various depth were very consistent and do not vary with reference depth. These findings confirm that the clinical use of the BJR (supplement 21) Table of equivalent squares for total scatter factors and phantom scatter related quantities of rectangular fields is

  13. Use of gamma radiation cobalt 60 for disinfestation of Lasioderma serricorne (Fabricius, 1972) (Coleoptera: Anobiidae) in Chamomilla recutita L. and Pimpinela anisum L. dehydrated

    Energy Technology Data Exchange (ETDEWEB)

    Alves, Juliana Nazare; Potenza, Marcos Roberto [Instituto Biologico, Sao Paulo, SP (Brazil). Centro de Pesquisa e Desenvolvimento de Sanidade Vegetal]. E-mail: julianaabc@ig.com.br; Arthur, Valter [Centro de Energia Nuclear na Agricultura (CENA/USP), Piracicaba, SP (Brazil)]. E-mail: arthur@cena.usp.br

    2008-03-15

    Stores products such a grains, flours, dry fruits and spices are normally infested by pests as beetles (Lasioderma serricorne), mites and moths, depreciating the product visually and promoting its deterioration. To improve the quality of spices, medicinal plants and others foodstuffs there is a need for adequate methods of handling, correct identification of the species, adequate collection and storage. The objective of this work was to determine the dose of gamma radiation for the disinfestation of medicinal and aromatic plants infested by L. serricorne. The plants used in this study were Chamomilla recutita L. and Pimpinela anisum L. in this dehydrated form. The experiment was carried out in the Laboratorio de Inseticidas e Acaricidas from Instituto Biologico/SP, during the months of January and May 2006, and the irradiations were carried out in the Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN/SP, using and experimental Cobalt 60 irradiator, model Gammacell 220. Each treatment consisted of 5 parcels containing 10 g of dehydrated products infested with 20 last instar larvae of L. serricorne, conditioned in plastic 10 x 10 cm containers with small punctures in the cover to allow internal aeration. The substratum previously infested was submitted to increasing doses of gamma radiation: 0: 0.5; 0.75; 1.0; 1.25; 1.50; 1.75; 2.0; 2.25; 2.50 and 2.75 kGy. After irradiation, the samples were kept in a acclimatized room at 27 {+-} 2 deg C of temperature and relative humidity of 70 {+-} 5% and after a 45 days period the number of adults insects emerged was evaluated. The disinfestation dose of gamma radiation for last instar larvae L. serricorne on Chamomilla recutita L. and Pimpinela anisum L. was 2.0 kGy. (author)

  14. Use of gamma radiation cobalt 60 for disinfestation of Lasioderma serricorne (Fabricius, 1972) (Coleoptera: Anobiidae) in Cymbopogon citratus stapf and Ocimun basillicum L. dehydrated

    Energy Technology Data Exchange (ETDEWEB)

    Ramos, Amanda C.O.; Potenza, Marcos R.; Alves, Juliana N.; Justi Junior, Joao [Instituto Biologico, Sao Paulo, SP (Brazil). Centro de Pesquisa e Desenvolvimento de Sanidade Vegetal]. E-mail: potenza@biologico.sp.gov.br; Arthur, Valter [Centro de Energia Nuclear na Agricultura (CENA), Piracicaba, SP (Brazil)]. E-mail: arthur@cena.usp.br

    2007-07-01

    Stored products such as grains, flours, dry fruits and spices are normally infested by pests as beetles (Lasioderma serricorne), mites and moths, depreciating the product visually and promoting its deterioration. To improve the quality of spices, medicinal plants, seasoning and others foodstuffs there is a need for adequate methods of handling, correct identification of the species, adequate collection, pre and post-treatment procedures and adequate storage. The objective of this work was to determine the dose of gamma radiation for the disinfestations of medicinal and aromatic plants dehydrated infested by L. serricone. The plants used in this study were Cymbopogon citratus stapf (lemon grass) and Ocimun basillicum L. (basil) in this dehydrated form. The experiment was carried out in the Arthropods Laboratory of the Instituto Biologico/SP, during the months of January and May 2006, and the irradiations were carried out in the Instituto de Pesquisas Energeticas e Nucleares-IPEN/CNEN/SP, using an experimental Cobalt 60 irradiator, model Gammacell 220. Each treatment consisted of 5 parcels containing 10g of dehydrated products infested with 20 last instar larvae of L. serricorne, conditioned in plastic 10x10 cm containers with small punctures in the cover to allow internal aeration. The substratum previously infested was kept for 1 day in a acclimatized room at 27 {+-} 2 deg C, after this period the substratum was submitted to increasing doses of gamma radiation: 0; 0,5; 0,75; 1,0; 1,25; 1,50; 1,75; 2,0; 2,25; 2,50 e 2,75 kGy. After irradiation, the samples were kept in a acclimatized room at 27 {+-} 2 deg C of temperature and relative humidity of 70 {+-} 5 % and after a 45 days period the number of adults insects emerged was evaluated. The lethal dose of gamma radiation for L. serrricorne last instar larvae on Cymbopogon citratus stapf and Ocimun basillicum L. was 1,75 kGy. (author)

  15. Effects of gamma radiation of Cobalt-60 on arabica and conillon seeds coffea: physic-chemistry evaluation; Efeitos da radiacao gama do Cobalto-60 em sementes de cafe arabica e conillon: avaliacao fisico-quimica

    Energy Technology Data Exchange (ETDEWEB)

    Silva, Marcus Henriques da

    2012-07-01

    Brazil is the largest producer and exporter of coffee in the world. The coffee bean is one of the main products of the Brazilian trade balance. Two species of coffee are the most economically important: the Coffea arabica L. and Coffea canephora Pierre is the largest representative of the Coffea canephora Pierre is the coffea conillon. Food irradiation is an area of research that aims to increase the shelf life of foods and controlling pests. This study aimed to verify the physicochemical variables of Arabica coffee and conillon were affected when exposed to doses of gamma radiation from cobalt-60. The samples were provided by Polo in Coffee Quality Technology, Federal University of Lavras - UFLA. The coffee samples were subjected to irradiation doses: 0 (control), 5 kGy and 10 kGy, a multipurpose irradiator of IPEN - Research Institute of Nuclear Energy and the University of São Paulo, at a rate of 7.5 kGy / hour. For irradiation the samples were vacuum-packed in appropriate packaging aluminised. After the process of irradiation the samples were stored at a temperature of 15 ± 1 deg C and relative humidity of 17 ± 1%. The following analyzes were performed: levels of total sugars, glucose, sucrose, caffeine, humidity, pH, total acidity, electrical conductivity and fibers. Analyses were performed 1, 30, 60 and 90 days after irradiation, and the results were submitted to analysis of variance and means were compared by Tukey test at 5%. It was observed that the analysis results of the samples irradiated with 5 kGy and 10 kGy showed values similar to the control. It was concluded that irradiation did not induce deleterious effects on arabica coffee seeds and conillon irradiated with 5 kGy and 10 kGy to 90 days after irradiation. (author)

  16. Single institutional retrospective analysis: treatment of choroidal melanomas with cobalt-60 brachytherapy Análise retrospectiva uni-institucional: tratamento de melanomas de coróide com braquiterapia utilizando cobalto-60

    Directory of Open Access Journals (Sweden)

    Antônio Cássio Assis Pellizzon

    2004-06-01

    Full Text Available PURPOSE: To evaluate the outcome of patients with choroidal melanoma treated with conservative therapy with brachytherapy (episcleral Co-60 plaque therapy at the "Hospital do Cancer" São Paulo, Brazil. METHODS: We evaluated 102 patients consecutively treated from January, 1999 to June, 1999. Median age, maximum tumor base diameter and apex size were 55.5 years, 9.75 mm and 5 mm, respectively. Doses at the base of the tumor, including 1 mm of sclera, ranged from 157 to 487 Gy (median 284.5 Gy and to the apex from 37 to 220 Gy (median 106 Gy. RESULTS: The crude eye preservation rate with conservative therapy alone was 78.5%. Five-year overall actuarial survival rate was 92.2% and eye conservation rate was 78%. Side effects were mostly an uncomplicated retinopathy in 39/102 patients (38.2%; macular degeneration or scarring led to poor central vision in 31/102 patients (30.3% of cases. CONCLUSION: Our experience with cobalt-60 plaque brachytherapy achieved a satisfactory rate of local tumor control, despite the oversized base diameters of treated tumors.OBJETIVOS: Para avaliar o resultado de tratamento pacientes portadores de melanoma de coróide tratados com braquiterapia (placas episclerais de Co-60 no Hospital do Câncer, São Paulo, Brasil. MÉTODOS: Foram avaliados 108 pacientes tratados consecutivamente de janeiro de 1995 a junho de 1999, com idade mediana de 55,5 anos, diâmetro da base do tumor e altura máximos 9,75 mm e 5 mm, respectivamente. As doses na base do tumor, incluindo 1 mm de esclera variaram de 157 a 487 Gy (mediana 284,5 Gy e para o ápice de 37 até 220 Gy (mediana 106 Gy. RESULTADOS: A taxa de preservação ocular foi 78,5%, com sobrevida atuarial global em cinco anos, e a taxa de conservação ocular atuarial foram 92,2% e 78%, respectivamente. Os principais efeitos colaterais relacionados ao tratamento foram retinopatia em 39/102 (38,2% pacientes e degeneração macular, levando a déficit visual central em 31/102 (30

  17. Cobalt-60 radiation leukemogenesis studies

    International Nuclear Information System (INIS)

    Kawakami, T.G.; Cain, G.R.; Taylor, N.J.; Shifrine, M.; Goldman, M.

    1985-01-01

    Canine myeloblastic leukemia cells are not metabolically a homogeneous population. Isotopic ( 3 H-thymidine) and immunofluorescent labelling of blastic leukemia cells for DNA synthesis indicated that active DNA synthesis occurred in small populations (10-30%) while the remaining cells were at maturation arrest. This characteristic of reduced DNA synthesis is common to granulocytic, monocytic and megakaryoblastic leukemia. Based on allo-transplantation studies, malignancy of leukemic cells is a constitutive property of the cells. A protein factor produced by the leukemic cell is responsible for maturation arrest. Based on SDS-polyacrylamide gel electrophoresis, the maturation arrest factor consist of several peptides. Long-term cultures of leukemic cells have been established. Molecular studies for malignant transformation are now underway. 3 figures, 2 tables

  18. Progeny of Spalangia endius Walker, 1839 (Hymenoptera: Pteromalidae) in Musca domestica L., 1758 (Diptera: Muscidae) non-viable pupae irradiated by gamma Cobalt-60 and cold stored

    International Nuclear Information System (INIS)

    Itepan, Sara Eloiza Zen.

    1992-06-01

    This study was designed to test acceptability of cold stored irradiated and non-irradiated pupae of Musca domestica L., 1758 (Diptera: Muscidae) by the parasitoid Spalangia endius Walker, 1839 (Hymenoptera: Pteromalidae). The work was carried out in the laboratory of the Entomology Section of the Center of Nuclear Energy in Agriculture (CENA/USP) and in the laboratory of Biological Control of House Flies Eduardo Hiroshi Mizumoto of Entomology Department of the College of Agriculture Luiz de Queiroz (ESALQ/USP), Piracicaba, Sao Paulo, Brazil. The gamma radiation source used was a Cobalt-60 irradiator, Gamma bean-650, with an initial activity of 1,6265 x 10 4 Bq (6,746 Ci). The radiation LD 50 e LD 100 , using a dose ratio of 1457 Gy/h, for 12, 24, 36, 48, 60 and 72 hours old pupae and resulted in 15.35; 15.69; 11.30; 49.4; 142.78 and 175 Gy for LD 50 and 20, 22.5; 32.5; 175; 225 and 300 Gy for LD'1 00 respectively. Following exposure, the pupae were kept in climate chamber at 27 ± 3 0 C and 75 ± % of relative humidity, until all adults had emerged. In succession, 24, 48 and 72 hour-old pupae were exposed to gamma irradiation with a dose of 1440 Gy/hour, in their respective lethal doses. Following the exposure the pupae were stored at cool temperature (10 ± 2 0 C) for different periods of time (5, 15, 20 and 30 days). The same treatment was given for non-irradiated pupae. After the storage period the pupae were expose for 24 h to S. endius in a ratio of 1:10 parasitoid-host. It was not observed any statistical difference (Turkey 5%) in progeny of males and females emerged from irradiated and non-irradiated pupae. There was a preference of the parasitoid to pupae of 48 hours old followed by 24 and 72 hours old for storage period more than 5 days and shorter than 20 days. (author). 50 refs., 6 figs., 17 tabs

  19. Dependence of some transmission factors on field size and treatment depth in external beam radiation therapy (EBRT) using the theratron equinox 100 cobalt 60 machine

    International Nuclear Information System (INIS)

    Odonkor, P.

    2015-07-01

    The use of beam modifiers in today’s radiotherapy is very important as it attenuates the beam and reduces the dose to the patient; therefore the need to know the amount of attenuation (in terms of a transmission factor) they provide during treatment. The purpose of this research work is to evaluate the variation (or dependence) of the transmission factors (TFs) of block tray and physical wedges (of different angles) as a function of treatment depth and field size using both iso-centric setups, SAD and SSD; and thus compare the results from the two setup techniques. Wedge and tray TF measurements were performed in a full scatter, large water phantom using a 0.04cc ionization chamber and an average photon energy of 1.25MV from a cobalt-60 unit at an SAD/SSD of 100cm at various depths and field sizes with gantry and collimator angles fixed at 0°. From the measurements carried out, the wedge TF of the 15°, 30°, 45°, and 60°, wedges were found to be 0.775±0.005, 0.650±0.010, 0.505±0.015, and 0.280±0.015 respectively; and the tray TF was found to be 0.960±0.003. Also, the results obtained showed that both the wedge TF and the tray TF has a strong linear dependence on treatment depth; however, the variation of the 15°, wedge TF and the tray TF with depth is less significant (less than 2%). Maximum percentage variation for the 15°, wedge for the SAD setup was 1.1% and 1.59% for the SSD setup; and that for the tray was 0.60% for the SAD setup and 0.12% for the SSD setup. Also, the variation of the 15°, 30°, and 45°, wedge TF with field size was less significant (less than 2%); and a weaker dependence was observed with field size as compared to the treatment depth. However, the 60°, wedge showed a significant variation (maximum of 2.22% and 2.88% for the SAD and SSD setups respectively) as an increase in field size was accompanied by an increase in its wedge TF. Also though the tray TF graphically showed a strong linear dependence on field size the

  20. Degradation of the insecticide ethyl parathion in different environmental matrices by gamma radiation from Cobalt-60; Degradacao do inseticida paration etilico em diversas matrizes ambientais por meio de radiacao ionizante gama do cobalto-60

    Energy Technology Data Exchange (ETDEWEB)

    Luchini, Luiz Carlos

    1995-07-01

    This work studies the use of gamma radiation from cobalt-60 to induce parathion degradation in different matrices, as well as, quantified GC-NPD and identified by GC-MS, the radiolysis resulting products. Results show that the insecticide was completely degraded in aqueous solution after treatment with 1.0 kGy dosis in a dosis rate of 3.12 kGy h{sup -1}. In methanol, parathion was completely degraded only with 30 kGy at 3.12 kGy h{sup -1}. The metabolites detected after radiolysis were the same formed by biological degradation, i.e, p-nitrophenol, p-aminophenol, paraoxon and aminoparathion. The gamma radiation also degraded paraoxon which is the most toxic metabolite of parathion. It was verified that, not only the total radiation, but also the dosis rate supplied to the aqueous solution had a significant effect on the insecticide degradation, and the formation of metabolites occurred in a selective way respecting the dosis and dosis rate. Otherwise, the gamma radiation did almost not degraded the parathion adsorbed in solid matrices as rice, moist and dry soil, even using dosis of 5,30 and 50 kGy, respectively. The parathion yield and the dosis of gamma radiation needed for 50% reduction of the insecticide initial concentration in aqueous solution were also calculated and presented. Thus, it was verified that irradiation of parathion besides to be an important instrument for environmental decontamination of this pesticide in aqueous matrix, it allows the production of parathion metabolites for ecotoxicological studies. (author)

  1. Use of gamma radiation cobalt 60 for disinfestation of Lasioderma serricorne (Fabricius, 1972) (Coleoptera: Anobiidae) in Cymbopogon citratus stapf and Ocimun basillicum L. dehydrated

    International Nuclear Information System (INIS)

    Ramos, Amanda C.O.; Potenza, Marcos R.; Alves, Juliana N.; Justi Junior, Joao

    2007-01-01

    Stored products such as grains, flours, dry fruits and spices are normally infested by pests as beetles (Lasioderma serricorne), mites and moths, depreciating the product visually and promoting its deterioration. To improve the quality of spices, medicinal plants, seasoning and others foodstuffs there is a need for adequate methods of handling, correct identification of the species, adequate collection, pre and post-treatment procedures and adequate storage. The objective of this work was to determine the dose of gamma radiation for the disinfestations of medicinal and aromatic plants dehydrated infested by L. serricone. The plants used in this study were Cymbopogon citratus stapf (lemon grass) and Ocimun basillicum L. (basil) in this dehydrated form. The experiment was carried out in the Arthropods Laboratory of the Instituto Biologico/SP, during the months of January and May 2006, and the irradiations were carried out in the Instituto de Pesquisas Energeticas e Nucleares-IPEN/CNEN/SP, using an experimental Cobalt 60 irradiator, model Gammacell 220. Each treatment consisted of 5 parcels containing 10g of dehydrated products infested with 20 last instar larvae of L. serricorne, conditioned in plastic 10x10 cm containers with small punctures in the cover to allow internal aeration. The substratum previously infested was kept for 1 day in a acclimatized room at 27 ± 2 deg C, after this period the substratum was submitted to increasing doses of gamma radiation: 0; 0,5; 0,75; 1,0; 1,25; 1,50; 1,75; 2,0; 2,25; 2,50 e 2,75 kGy. After irradiation, the samples were kept in a acclimatized room at 27 ± 2 deg C of temperature and relative humidity of 70 ± 5 % and after a 45 days period the number of adults insects emerged was evaluated. The lethal dose of gamma radiation for L. serrricorne last instar larvae on Cymbopogon citratus stapf and Ocimun basillicum L. was 1,75 kGy. (author)

  2. Analysis of radioactive cobalt

    International Nuclear Information System (INIS)

    1977-01-01

    This is a manual published by Science and Technology Agency, Japan, which prescribes on the analysis method for radioactive cobalt which is a typical indexing nuclide among the radioactive nuclides released from nuclear facilities. Since the released cobalt is mainly discharged to coastal region together with waste water, this manual is written for samples of sea water, sea bottom sediments and marine organisms. Radioactive cobalt includes the nuclides of 57 co, 58 Co, 60 Co, etc., the manual deals with them as a whole as 60 Co of long half life. Though 60 Co analysis has become feasible comparatively simply due to scintillation or semi-conductor spectrometry, trace 60 Co analysis is performed quantitatively by co-precipitation or collection into alumina and scintillation spectrometry. However, specific collecting operation and γ-γ coincidence measurement have been required so far. This manual employs 60 Co collection by means of ion-exchange method and measurement with low background GM counting system, to analyze quantitatively and rapidly low level 60 Co. It is primarily established as the standard analyzing method for the survey by local autonomous bodies. It is divided into 4 chapters including introduction sea water, marine organisms, and sea bottom sediments. List of required reagents is added in appendix. (Wakatsuki, Y.)

  3. Feasibility Study for Cobalt Bundle Loading to CANDU Reactor Core

    International Nuclear Information System (INIS)

    Park, Donghwan; Kim, Youngae; Kim, Sungmin

    2016-01-01

    CANDU units are generally used to produce cobalt-60 at Bruce and Point Lepreau in Canada and Embalse in Argentina. China has started production of cobalt-60 using its CANDU 6 Qinshan Phase III nuclear power plant in 2009. For cobalt-60 production, the reactor’s full complement of stainless steel adjusters is replaced with neutronically equivalent cobalt-59 adjusters, which are essentially invisible to reactor operation. With its very high neutron flux and optimized fuel burn-up, the CANDU has a very high cobalt-60 production rate in a relatively short time. This makes CANDU an excellent vehicle for bulk cobalt-60 production. Several studies have been performed to produce cobalt-60 using adjuster rod at Wolsong nuclear power plant. This study proposed new concept for producing cobalt-60 and performed the feasibility study. Bundle typed cobalt loading concept is proposed and evaluated the feasibility to fuel management without physics and system design change. The requirement to load cobalt bundle to the core was considered and several channels are nominated. The production of cobalt-60 source is very depend on the flux level and burnup directly. But the neutron absorption characteristic of cobalt bundle is too high, so optimizing design study is needed in the future

  4. Feasibility Study for Cobalt Bundle Loading to CANDU Reactor Core

    Energy Technology Data Exchange (ETDEWEB)

    Park, Donghwan; Kim, Youngae; Kim, Sungmin [KHNP Central Research Institute, Daejeon (Korea, Republic of)

    2016-10-15

    CANDU units are generally used to produce cobalt-60 at Bruce and Point Lepreau in Canada and Embalse in Argentina. China has started production of cobalt-60 using its CANDU 6 Qinshan Phase III nuclear power plant in 2009. For cobalt-60 production, the reactor’s full complement of stainless steel adjusters is replaced with neutronically equivalent cobalt-59 adjusters, which are essentially invisible to reactor operation. With its very high neutron flux and optimized fuel burn-up, the CANDU has a very high cobalt-60 production rate in a relatively short time. This makes CANDU an excellent vehicle for bulk cobalt-60 production. Several studies have been performed to produce cobalt-60 using adjuster rod at Wolsong nuclear power plant. This study proposed new concept for producing cobalt-60 and performed the feasibility study. Bundle typed cobalt loading concept is proposed and evaluated the feasibility to fuel management without physics and system design change. The requirement to load cobalt bundle to the core was considered and several channels are nominated. The production of cobalt-60 source is very depend on the flux level and burnup directly. But the neutron absorption characteristic of cobalt bundle is too high, so optimizing design study is needed in the future.

  5. Radio cobalt in French rivers

    International Nuclear Information System (INIS)

    Lambrechts, A.; Baudin-Jaulent, Y.

    1996-01-01

    The isotopes 58 and 60 of cobalt present in liquid wastes from nuclear plants or from fuel reprocessing plant of Marcoule are fixed in the different compartments of French rivers. The activity levels of radio-cobalt vary according to the sampled compartments nature (bryophyta > immersed plants > sediment > fish). Elsewhere, laboratory experimentations show that the contamination of fish occurs essentially from the water way rather than from food. Cobalt is mainly fixed by kidneys; muscles is no more than 30 % of the total fish activity. (author)

  6. Studies of the yields of 57Fe(II)-species produced after the EC-decay and of 60Co(II)-species produced in the (n, γ) reaction in cobalt(III) coordination compounds

    International Nuclear Information System (INIS)

    Sano, Hirotoshi; Harada, Masayuki; Endo, Kazutoyo

    1978-01-01

    The yields of 57 Fe(II)-species produced after EC-decay were compared with those of 60 Co(II)-species produced in the 59 Co(n, γ) 60 Co reaction for twelve cobalt(III) coordination compounds. The results indicate that the radiochemical yield of 60 Co(II)-species correlates with the yield of 57 Fe(II)-species except in the case of [Co(NH 3 ) 6 ] 2 (CrO 4 ) 3 . The anomalously low yield of 57 Fe(II)-species in [Co(NH 3 ) 6 ] 2 (CrO 4 ) 3 is ascribed to the reaction of chromate anions with ammine ligands initiated by the nuclear transformation in a solid. (author)

  7. Early effects of treatment with radium and cobalt-60 gamma radiation on the proportions and absolute counts of T and B lymphocytes in peripheral blood of women with cervical carcinoma

    International Nuclear Information System (INIS)

    Pluzanska, A.; Robak, T.; Kuchowicz, W.; Bartuzel, T.; Studencki, E.; Zadrozna, O.; Mazurowa, A.

    1977-01-01

    In 20 women with cervical carcinoma the T and B lymphocyte counts were determined in peripheral blood. The determinations were carried out before starting treatment and immediately after radium therapy in a mean dose of 6573 mgh and then after full therapeutic dose of cobalt-60 radiation of 4000 R. For identification of T lymphocytes the rosette E test was used and lymphocytes B were identified by means of the EAC rosette test. Presence of immunoglobulins on lymphocytes B was determined as well. In women with cervical carcinoma the total lymphocyte count in 1 mm 3 of blood, the proportions and absolute counts of T and B lymphocytes were not different from those in healthy women. Immediately after radium therapy the lymphocyte count in peripheral blood fell which was due mainly to a fall of the total count and in the proportion of B lymphocytes. The proportion of lymphocytes T was unchanged and their quantitative fall was statistically not significant. After application of the total therapeutic dose of cobalt-60 radiation a further fall of lymphocyte count was observed, due to a fall of the absolute count of T and B lymphocytes. Their proportions were unchanged. (author)

  8. The behaviour of cesium 137, chromium 51, cobalt 60, Manganese 54, sodium 22 and zinc 65 in simulated estuarine environments. Effects of suspended mineral particles and dissolved organic matters

    International Nuclear Information System (INIS)

    Mahler, P.

    1985-09-01

    This laboratory investigation studied the retention of 6 radionuclides (cesium 137, chrome 51, cobalt 60, manganese 54, sodium 22 and zinc 65) on three types of clay particles (kaolinite, illite, montmorillonite) and on sediments, suspended in media with salinities ranging between 0 and 34 per mill, with or without organic matters. Measurement of the radioactivity retained by the particles after 5 days' contact with the radionuclide made it possible to calculate the percentages retained and the distribution coefficients, and to follow their evolution versus salinity. Parallel experiments studied the behaviours of the 6 radionuclides as a function of experimental factors (wall effect, contact time..). An exhaustive bibliographic review gives the state-of-the-art of the knowledge. The following conclusions were derived: - the retention of all the radionuclides but chromium 51 decreased as soon as a low salinity appeared. Chromium (available as Cr 3+ ) precipitated quickly and strongly during fixation whatever the surfaces or the conditions: - as for the role of the clay type, illite showed a strong affinity for cesium 137; manganese 54 had a particular behaviour with montmorillonite that enhanced its precipitation into MnO 2 ; with cobalt, sodium and zinc, the percentages retained were always [fr

  9. Cobalt production in RAPS-1

    International Nuclear Information System (INIS)

    Krishnan, P.D.; Purandare, H.D.

    1978-01-01

    At present in RAPS-1 radioisotope Co 60 is produced by irradiating Co 59 in the adjusters which perform the function of regulation of reactivity, power and xenon override. But the manrem expenditure of the crew handling the charge and discharge of the adjusters is going to be prohibitively high. It is therefore proposed to irradiate Co 59 in the fuel channel positions. The physics optimisation study for such irradiation is presented. The burnup penalty and loss of power are estimated to produce the required quantity of Co 60 after optimising the number of cobalt pencils in a bundle and the positions of the cobalt producing channels in the reactor core. (author)

  10. SU-E-J-198: Out-Of-Field Dose and Surface Dose Measurements of MRI-Guided Cobalt-60 Radiotherapy

    International Nuclear Information System (INIS)

    Lamb, J; Agazaryan, N; Cao, M; Low, D; Thomas, D; Yang, Y

    2015-01-01

    Purpose: To measure quantities of dosimetric interest in an MRI-guided cobalt radiotherapy machine that was recently introduced to clinical use. Methods: Out-of-field dose due to photon scatter and leakage was measured using an ion chamber and solid water slabs mimicking a human body. Surface dose was measured by irradiating stacks of radiochromic film and extrapolating to zero thickness. Electron out-of-field dose was characterized using solid water slabs and radiochromic film. Results: For some phantom geometries, up to 50% of Dmax was observed up to 10 cm laterally from the edge of the beam. The maximum penetration was between 1 and 2 mm in solid water, indicating an electron energy not greater than approximately 0.4 MeV. Out-of-field dose from photon scatter measured at 1 cm depth in solid water was found to fall to less than 10% of Dmax at a distance of 1.2 cm from the edge of a 10.5 × 10.5 cm field, and less that 1% of Dmax at a distance of 10 cm from field edge. Surface dose was measured to be 8% of Dmax. Conclusion: Surface dose and out-of-field dose from the MRIguided cobalt radiotherapy machine was measured and found to be within acceptable limits. Electron out-of-field dose, an effect unique to MRI-guided radiotherapy and presumed to arise from low-energy electrons trapped by the Lorentz force, was quantified. Dr. Low is a member of the scientific advisory board of ViewRay, Inc

  11. The physiological effect of cobalt on watermelon cultivation

    International Nuclear Information System (INIS)

    Yao Naihua; Jin Yafang; Sun Yaochen; Huang Yiming

    1993-01-01

    Cobalt has essential physiological action on both animals and plants. For the latter it can raise plant's nitrogen-fixing ability and saccharine content. Spray of cobalt mixed with other nutritive elements can improve the germinatit of seeds and the yield of fruit. For specifying the nutritive function of cobalt upon watermelon, isotope 60 Co was mixed into a complex leaf nutritive aqua and the regularity of transferring and absorbing cobalt in the watermelon's body was investigated

  12. Accumulation of cobalt by cephalopods

    International Nuclear Information System (INIS)

    Nakahara, Motokazu

    1981-01-01

    Accumulation of cobalt by cephalopod mollusca was investigated by radiotracer experiments and elemental analysis. In the radiotracer experiments, Octopus vulgaris took up cobalt-60 from seawater fairly well and the concentration of the nuclide in whole body attained about 150 times the level of seawater at 25th day at 20 0 C. Among the tissues and organs measured, branchial heart which is the specific organ of cephalopods showed the highest affinity for the nuclide. The organ accumulated about 50% of the radioactivity in whole body in spite of its little mass as 0.2% of total body weight. On the other hand, more than 90% of the radioactivity taken up from food (soft parts of Gomphina melanaegis labelled with cobalt-60 previously in an aquarium) was accumulated in liver at 3rd day after the single administration and then the radioactivity in the liver seemed to be distributed to other organs and tissues. The characteristic elution profiles of cobalt-60 was observed for each of the organs and tissues in Sephadex gel-filtration experiment. It was confirmed by the gel-filtration that most of cobalt-60 in the branchial heart was combined with the constituents of low molecular weights. The average concentration of stable cobalt in muscle of several species of cephalopods was 5.3 +- 3.0 μg/kg wet and it was almost comparable to the fish muscle. On the basis of soft parts, concentration of the nuclide closed association among bivalve, gastropod and cephalopod except squid that gave lower values than the others. (author)

  13. Measurement for cobalt target activity and its axial distribution

    International Nuclear Information System (INIS)

    Li Xingyuan; Chen Zigen.

    1985-01-01

    Cobalt target activity and its axial distribution are measured in process of producing radioactive isotopes 60 Co by irradiation in HFETR. Cobalt target activity is obtained with measured data at 3.60 m and 4.60 m, relative axial distribution of cobalt target activity is obtained with one at 30 cm, and axial distribution of cobalt target activity(or specific activity) is obtained with both of data. The difference between this specific activity and measured result for 60 Co teletherapy sources in the end is less than +- 5%

  14. Cobalt accumulation and circulation by blackgum trees

    International Nuclear Information System (INIS)

    Thomas, W.A.

    1975-01-01

    Blackgum (Nyssa sylvatica Marsh.) trees accumulate far greater concentrations of cobalt in mature foliage than do other species on the same site (363 ppM in ash of blackgum, compared with about 3 ppM by mockernut hickory and about 1 ppM by red maple, tulip tree, and white oak). Cobalt concentrations in dormant woody tissues of blackgum also significantly exceed those in the other four species. Inoculation of six blackgums with 60 Co revealed that cobalt remains mobile in the trees for at least 3 years. Foliar concentrations of stable cobalt increase uniformly until senescence. In late August, foliage accounts for only 9 percent of total tree weight but 57 percent of total tree cobalt. Losses of cobalt from trees occur almost entirely by leaf abscission, and the loss rates of weight and cobalt from decomposing litter are similar. Retention of cobalt in the biologically active soil layers perpetuates zones of cobalt concentration created by this species in woodlands

  15. Final environmental statement concerning rule making. Exemption from licensing requirements for spark-gap irradiators that contain cobalt-60. Docket No. PRM 30-54

    International Nuclear Information System (INIS)

    1977-12-01

    The potential environmental impacts and adverse environmental effects from distribution, use only in commercial-sized oil burners, and disposal of 6000 spark-gap irradiators per year that contain 60 Co are summarized. On the basis of the analysis and evaluation set forth in this statement and after weighing the environmental, economic, technical, and other benefits against environmental costs and after considering available alternatives, it is concluded that the action called for under the National Environmental Policy Act of 1969 (NEPA) and 10 CFR Part 51 is the issuance of an exemption from licensing requirements for spark-gap irradiators that contain 60 Co, subject to the following conditions for the protection of the environment: persons who apply 60 Co to, or persons who incorporate 60 Co into, spark-gap irradiators or persons who import for sale or distribution spark-gap irradiators containing 60 Co are not exempt from the requirements for a license; each spark-gap irradiator shall contain no more than 1 μCi of 60 Co; and the 60 Co shall be applied to the spark-gap irradiators for use in electrically ignited fuel-oil burners having a firing rate of at least 3 gal/h

  16. Comparison of the effects of 50 MeV/sub d → Be/ neutron and cobalt-60 irradiation of the kidneys of Rhesus monkeys

    International Nuclear Information System (INIS)

    Raulston, G.L.; Gray, K.N.; Gleiser, C.A.; Jardine, J.H.; Flow, B.L.; Huchton, J.I.; Bennett, K.R.; Hussey, D.H.

    1978-01-01

    Twenty rhesus monkeys had one kidney irradiated (after undergoing unilateral nephrectomies) with one of four doses: 960 or 1080 rads of 50 MeV/sub d→Be/ neutrons, or 2350 or 2700 rads of 60 Co. Whereas animals treated with the lower dose of neutrons or 60 Co are alive with relatively normal renal function, those treated with the higher dose of neutrons died of radiation nephritis. Animals treated with the higher dose of 60 Co developed radiation nephritis but survived. The physiological and histopathological changes of radiation nephritis secondary to neutron irradiation are not qualitatively different from those reported for radiation nephritis secondary to photon irradiation

  17. Effects of gamma radiation of Cobalt-60 on different phases of the evolutive cycle of pinworm - Tuta absoluta (Meyrich, 1917) (Lepidoptera,Gelechiidae); Efeitos da radiacao gama do Cobalto-60 nas diferentes fases do ciclo evolutivo da traca do tomateiro - Tuta absoluta (Meyrich, 1917) (Lepidoptera, Gelechiidae)

    Energy Technology Data Exchange (ETDEWEB)

    Groppo, Gerson Antonio

    1996-10-01

    The effects of different gamma radiation (Cobalt-60) doses on different phases of the evolutive cycle of Tuta absoluta (Meyrich, 1917) (Lepidoptera, Gelechiidae) have been studied under laboratory conditions in the laboratory of Entomology of Center for Nuclear Energy in Agriculture (CENA), University of Sao Paulo, Piracicaba, Sao Paulo State, Brazil. For all the treatments with gamma radiation a Cobalt-60 source type Gamma beam-650 was used. The doses utilized ranged from of 0,0 (Control) to 3250 Gy with a dose rate of 1110 Gy/h. The experiment was conducted under controlled conditions at 25{+-} 2 deg C, 70 {+-} 5% of relative humidity and photo period of (12:12). It was verified that the lethal doses were: for eggs - 70 Gy; for larvae - 200 Gy e for pupae - 300 Gy. The sterilizing dose for adults from irradiated larvae was 45 Gy. The sterilizing dose for the crossing of irradiated female with normal males (FI X MN) was 100 Gy and for normal female with irradiated male (FN x MI) was 150 Gy, in the both crosses, doses refer to irradiation of pupae. The sterilizing dose for adults, of both sexes, irradiated and crossed with normal adults, (FI x MN) and (FN x MI, were 150 and 200 Gy, respectively. The average longevity of adults, of both sexes, irradiated and crossed with normal adults was 8,3 days. The immediate lethal dose for adults was 3250 Gy. (author)

  18. Influence of the mode of uptake on the elimination of cobalt 60 by a phanerogam, a mollusc, a crustacean and a freshwater teleost

    International Nuclear Information System (INIS)

    Amiard-Triquet, C.

    1979-01-01

    60 Co enters the environment with radioactive wastes from nuclear power reactors and fuel reprocessing plants as well as a component of fallout from nuclear tests. A study of 60 Co in freshwater organisms has been carried out in order to compare the influence of different modes of uptake (immersion in contaminated water, ingestion of radioactive food, contamination by both food and water) upon the subsequent elimination. The loss of 60 Co by Canadian pondweed Elodea canadensis is monophasic. For animal species, this phenomenon is biphasic, independently of the mode of uptake. On the other hand, the biological half-life changes in relation to the vector of contamination. The same result is observed for the relative importance of the different compartments. This is easily explained because the mode of uptake determines the distribution of 60 Co in the organisms. The turnover of 60 Co in the organisms is slow and the physical half-life of this radionuclide is relatively important (Tsub(p) = 5.27 years). Thus, the possible consequences of the release of this pollutant on freshwater life must not be neglected. (author)

  19. Dosimetric feasibility of magnetic resonance imaging-guided tri-cobalt 60 preoperative intensity modulated radiation therapy for soft tissue sarcomas of the extremity.

    Science.gov (United States)

    Kishan, Amar U; Cao, Minsong; Mikaeilian, Argin G; Low, Daniel A; Kupelian, Patrick A; Steinberg, Michael L; Kamrava, Mitchell

    2015-01-01

    The purpose of this study was to investigate the dosimetric differences of delivering preoperative intensity modulated radiation therapy (IMRT) to patients with soft tissue sarcomas of the extremity (ESTS) with a teletherapy system equipped with 3 rotating (60)Co sources and a built-in magnetic resonance imaging and with standard linear accelerator (LINAC)-based IMRT. The primary study population consisted of 9 patients treated with preoperative radiation for ESTS between 2008 and 2014 with LINAC-based static field IMRT. LINAC plans were designed to deliver 50 Gy in 25 fractions to 95% of the planning target volume (PTV). Tri-(60)Co system IMRT plans were designed with ViewRay system software. Tri-(60)Co-based IMRT plans achieved equivalent target coverage and dosimetry for organs at risk (long bone, skin, and skin corridor) compared with LINAC-based IMRT plans. The maximum and minimum PTV doses, heterogeneity indices, and ratio of the dose to 50% of the volume were equivalent for both planning systems. One LINAC plan violated the maximum bone dose constraint, whereas none of the tri-(60)Co plans did. Using a tri-(60)Co system, we were able to achieve equivalent dosimetry to the PTV and organs at risk for patients with ESTS compared with LINAC-based IMRT plans. The tri-(60)Co system may be advantageous over current treatment platforms by allowing PTV reduction and by elimination of the additional radiation dose associated with daily image guidance, but this needs to be evaluated prospectively. Copyright © 2015 American Society for Radiation Oncology. Published by Elsevier Inc. All rights reserved.

  20. Report on salvage of a jammed cobalt-60 source of the gamma beam irradiator at Bangladesh Institute of Nuclear Agriculture (BINA), Mymensingh, Bangladesh

    International Nuclear Information System (INIS)

    Karim, S.M.F.; Awal, K.O.; Ali, M.A.T.

    1997-01-01

    This report is the follow-up of a recovery plan for a Co-60 source that was presented at the proceedings of a symposium at the International Atomic Energy Agency, Vienna during 6-10 November 1989. This report deals mainly with technical measures adopted to salvage the jammed Co-60 source of a gamma irradiator at the Bangladesh Institute of Nuclear Agriculture BINA, Mymensingh, Bangladesh. Different tools and devices were developed to allow the remote recovery of the source. The radiation safety measures taken and the device drawings are given, together with suggestions for future use of the source with the remaining activity for irradiation purposes. (author)

  1. Cobalt sorption onto Savannah River Plant soils

    International Nuclear Information System (INIS)

    Hoeffner, S.L.

    1985-06-01

    A laboratory study of cobalt-60 sorption was conducted using Savannah River Plant soil and groundwater from the low-level waste burial ground. Systematic variation of soil and water composition indicates that cobalt sorption is most strongly a function of pH. Over a pH range of 2 to 9, the distribution coefficient ranged from 2 to more than 10,000 mL/g. Changes in clay content and in K + , Ca 2+ , or Mg 2+ concentrations influence cobalt sorption indirectly through the slight pH changes which result. The ions Na + , Cl - , and NO 3 - have no effect on cobalt sorption. Ferrous ion, added to groundwater to simulate the condition of water at the bottom of the waste trenches, accounts for part of the decrease in cobalt sorption observed with trench waters. 17 refs., 3 figs., 4 tabs

  2. A national survey of HDR source knowledge among practicing radiation oncologists and residents: Establishing a willingness-to-pay threshold for cobalt-60 usage.

    Science.gov (United States)

    Mailhot Vega, Raymond; Talcott, Wesley; Ishaq, Omar; Cohen, Patrice; Small, Christina J; Duckworth, Tamara; Sarria Bardales, Gustavo; Perez, Carmen A; Schiff, Peter B; Small, William; Harkenrider, Matthew M

    Ir-192 is the predominant source for high-dose-rate (HDR) brachytherapy in United States markets. Co-60, with longer half-life and fewer source exchanges, has piloted abroad with comparable clinical dosimetry but increased shielding requirements. We sought to identify practitioner knowledge of Co-60 and establish acceptable willingness-to-pay (WTP) thresholds for additional shielding requirements for use in future cost-benefit analysis. A nationwide survey of U.S. radiation oncologists was conducted from June to July 2015, assessing knowledge of HDR sources, brachytherapy unit shielding, and factors that may influence source-selection decision-making. Self-identified decision makers in radiotherapy equipment purchase and acquisition were asked their WTP on shielding should a more cost-effective source become available. Four hundred forty surveys were completed and included. Forty-four percent were ABS members. Twenty percent of respondents identified Co-60 as an HDR source. Respondents who identified Co-60 were significantly more likely to be ABS members, have attended a national brachytherapy conference, and be involved in brachytherapy selection. Sixty-six percent of self-identified decision makers stated that their facility would switch to a more cost-effective source than Ir-192, if available. Cost and experience were the most common reasons provided for not switching. The most common WTP value selected by respondents was decision makers to establish WTP for shielding costs that source change to Co-60 may require. These results will be used to establish WTP threshold for future cost-benefit analysis. Copyright © 2017 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.

  3. The Cobalt-60 Research Facility at Seibersdorf; L'Installation de Recherche sur l'Iradiation au {sup 60}Co de Seibersdorf; Obluchayushchaya ustanovka s istochnikom Kobal'ta-60 reaktornogo tsentra v Zajbersdorfe; La Instalacion Experimental de {sup 60}Co de Seibersdorf

    Energy Technology Data Exchange (ETDEWEB)

    Weidinger, N.; Kaindl, K. [Institute Of Biology And Agriculture, Reactor Centre, Seibersdorf (Austria)

    1966-11-15

    The irradiation facility which is now under construction at Seibersdorf was designed especially for research on the International Fruit Juice Programme. The plant consists of two irradiation chambers, with a capacity of 30 kCi and 10 kCi, respectively. The first is proposed to irradiate quantities of fruit juice for feeding tests and for investigations in source technology. The other was especially designed for research purposes in microbiology and chemistry and has an optimal versatility in source configuration and position according to the experiment conditions. The biological shield, ordinary concrete with a density of about 2.4 ton/m{sup 3}, gives an outside dose- rate of 0.2 mR/h maximum; The rest position of both sources is a lead cylinder let.into the shielding concrete. Twelve stainless-steel tubes (six tubes for the small chamber), in which the cobalt rods are fitted, pass in a spheric gangway into the irradiation chamber. The {sup 60}Co rods of the 30 kCi facility, each with an outside length of 300 mm, consist of two linked parts. They may be arranged individually or in any combination within five seconds by an air pressure system. Different tubes with the respective curvature allow practically every arrangement of source geometry. The chamber, measuring 3 x 3 X 3 m inside, may be closed by a concrete door; a binocular periscope enables the scientist to observe the experiment during irradiation. The other facility, measuring 3.5 x 3 x 3 m inside, can be entered through a labyrinth and has a source activity of 10 kCi. Six rods,- with an outside length of 250 mm, may be moved individually by Teleflex cable. They can be stopped in any position desired, measured from the entrance into the chamber. For observing experiments, a monocular periscope system is installed. The room is controlled at a temperature of between -18 Degree-Sign C and +35 Degree-Sign C, with an accuracy of {+-}1 Degree-Sign C. Several tubes, up to a diameter of 300 mm, pass the concrete

  4. A treatment planning comparison between modulated tri-cobalt-60 teletherapy and linear accelerator–based stereotactic body radiotherapy for central early-stage non−small cell lung cancer

    Energy Technology Data Exchange (ETDEWEB)

    Merna, Catherine; Rwigema, Jean-Claude M.; Cao, Minsong; Wang, Pin-Chieh; Kishan, Amar U.; Michailian, Argin; Lamb, James; Sheng, Ke; Agazaryan, Nzhde; Low, Daniel A.; Kupelian, Patrick; Steinberg, Michael L.; Lee, Percy, E-mail: percylee@mednet.ucla.edu

    2016-04-01

    We evaluated the feasibility of planning stereotactic body radiotherapy (SBRT) for large central early-stage non−small cell lung cancer with a tri-cobalt-60 (tri-{sup 60}Co) system equipped with real-time magnetic resonance imaging (MRI) guidance, as compared to linear accelerator (LINAC)–based SBRT. In all, 20 patients with large central early-stage non−small cell lung cancer who were treated between 2010 and 2015 with LINAC-based SBRT were replanned using a tri-{sup 60}Co system for a prescription dose of 50 Gy in 4 fractions. Doses to organs at risk were evaluated based on established MD Anderson constraints for central lung SBRT. R{sub 100} values were calculated as the total tissue volume receiving 100% of the dose (V{sub 100}) divided by the planning target volume and compared to assess dose conformity. Dosimetric comparisons between LINAC-based and tri-{sup 60}Co SBRT plans were performed using Student's t-test and Wilcoxon Ranks test. Blinded reviews by radiation oncologists were performed to assess the suitability of both plans for clinical delivery. The mean planning target volume was 48.3 cc (range: 12.1 to 139.4 cc). Of the tri-{sup 60}Co SBRT plans, a mean 97.4% of dosimetric parameters per patient met MD Anderson dose constraints, whereas a mean 98.8% of dosimetric parameters per patient were met with LINAC-based SBRT planning (p = 0.056). R{sub 100} values were similar between both plans (1.20 vs 1.21, p = 0.79). Upon blinded review by 4 radiation oncologists, an average of 90% of the tri-{sup 60}Co SBRT plans were considered acceptable for clinical delivery compared with 100% of the corresponding LINAC-based SBRT plans (p = 0.17). SBRT planning using the tri-{sup 60}Co system with built-in MRI is feasible and achieves clinically acceptable plans for most central lung patients, with similar target dose conformity and organ at risk dosimetry. The added benefit of real-time MRI-guided therapy may further optimize tumor targeting while

  5. A treatment planning comparison between modulated tri-cobalt-60 teletherapy and linear accelerator-based stereotactic body radiotherapy for central early-stage non-small cell lung cancer.

    Science.gov (United States)

    Merna, Catherine; Rwigema, Jean-Claude M; Cao, Minsong; Wang, Pin-Chieh; Kishan, Amar U; Michailian, Argin; Lamb, James; Sheng, Ke; Agazaryan, Nzhde; Low, Daniel A; Kupelian, Patrick; Steinberg, Michael L; Lee, Percy

    2016-01-01

    We evaluated the feasibility of planning stereotactic body radiotherapy (SBRT) for large central early-stage non-small cell lung cancer with a tri-cobalt-60 (tri-(60)Co) system equipped with real-time magnetic resonance imaging (MRI) guidance, as compared to linear accelerator (LINAC)-based SBRT. In all, 20 patients with large central early-stage non-small cell lung cancer who were treated between 2010 and 2015 with LINAC-based SBRT were replanned using a tri-(60)Co system for a prescription dose of 50Gy in 4 fractions. Doses to organs at risk were evaluated based on established MD Anderson constraints for central lung SBRT. R100 values were calculated as the total tissue volume receiving 100% of the dose (V100) divided by the planning target volume and compared to assess dose conformity. Dosimetric comparisons between LINAC-based and tri-(60)Co SBRT plans were performed using Student׳s t-test and Wilcoxon Ranks test. Blinded reviews by radiation oncologists were performed to assess the suitability of both plans for clinical delivery. The mean planning target volume was 48.3cc (range: 12.1 to 139.4cc). Of the tri-(60)Co SBRT plans, a mean 97.4% of dosimetric parameters per patient met MD Anderson dose constraints, whereas a mean 98.8% of dosimetric parameters per patient were met with LINAC-based SBRT planning (p = 0.056). R100 values were similar between both plans (1.20 vs 1.21, p = 0.79). Upon blinded review by 4 radiation oncologists, an average of 90% of the tri-(60)Co SBRT plans were considered acceptable for clinical delivery compared with 100% of the corresponding LINAC-based SBRT plans (p = 0.17). SBRT planning using the tri-(60)Co system with built-in MRI is feasible and achieves clinically acceptable plans for most central lung patients, with similar target dose conformity and organ at risk dosimetry. The added benefit of real-time MRI-guided therapy may further optimize tumor targeting while improving normal tissue sparing, which warrants further

  6. Sterilization of topical products by cobalt-60. Coordinated programme in practices for the radiation sterilization of medical supplies in countries of Asia and the Pacific Region

    International Nuclear Information System (INIS)

    Chong-Kook Kim

    1982-01-01

    The purpose of the test was to determine whether ointment can be sterilized or not by Co-60 irradiation. To evaluate the effect of radiosterilization, biological and physico-chemical tests have been performed. The effects of the Co-60 irradiation have always been compared with non-irradiated standard. The results showed that the ointment vehicles which were exposed in the air and contaminated from the surroundings contained no survivor germs after the irradiation with 2.5 Mrad doses. B. subtilis and B. pumilus which were artificial contaminants of ointment vehicles could not be detected after irradiation with 2.5 Mrad doses. The quantitative determinations of two ingredients (gentamicin and bufexamac) in ointments did not show changes between before and after irradiation. For the ointment vehicles no appearance changes have been observed, except slight discoloration. A change in hardness was observed after irradiation

  7. Effects of single and split doses of cobalt-60 gamma rays and 14 MeV neutrons on mouse stem cell spermatogonia.

    Science.gov (United States)

    Hacker-Klom, U B; Köhnlein, W; Göhde, W

    2000-12-01

    The long-term effects of ionizing radiation on male gonads may be the result of damage to spermatogonial stem cells. Doses of 10 cGy to 15 Gy (60)Co gamma rays or 10 cGy to 7 Gy 14 MeV neutrons were given to NMRI mice as single or split doses separated by a 24-h interval. The ratios of haploid spermatids/2c cells and the coefficients of variation of DNA histogram peaks as measures of both the cytocidal and the clastogenic actions of radiation were analyzed by DNA flow cytometry after DAPI staining. The coefficient of variation is not only a statistical examination of the data but is also used here as a measure of residual damage to DNA (i.e. a biological dosimeter). Testicular histology was examined in parallel. At 70 days after irradiation, the relative biological effectiveness for neutrons at 50% survival of spermatogonial stem cells was 3.6 for single doses and 2.8 for split doses. The average coefficient of variation of unirradiated controls of elongated spermatids was doubled when stem cells were irradiated with single doses of approximately 14 Gy (60)Co gamma rays or 3 Gy neutrons and observed 70 days later. Split doses of (60)Co gamma rays were more effective than single doses, doubling DNA dispersion at 7 Gy. No fractionation effect was found with neutrons with coefficients of variation.

  8. Main aspects in licensing of a type B(U) package design for the transport of 12.95 PBq of cobalt 60; Aspectos relevantes del licenciamiento en Argentina de un modelo de bulto tipo B(U) para transporte de 12,95 PBq de cobalto 60

    Energy Technology Data Exchange (ETDEWEB)

    Lopez Vietri, J R; Novo, R G; Bianchi, A J

    1996-12-31

    This paper points out the relevant technical issues related to the licensing process, of a type B(U) package design, with cylindrical form and 9.3 ton mass, approved by the Argentine Competent Authority for the transport of 12.95 PBq of cobalt 60 as special form radioactive material. It is briefly described the heat transfer analysis, the structural performance under impulsive loads and the shielding calculation under both normal and accidental conditions of transport, as well as the comparative analysis of the results obtained from design, pre-operational tests and independent evaluation performed by the Argentine Competent Authority to verify the compliance with the Regulations for the Safe Transport of Radioactive Material of the International Atomic Energy Agency. (author). 14 refs., 1 fig., tabs.

  9. Study of the effects of Cobalt 60 gamma radiations on the seeds of two textile hibiscus species. Influence of seed water content on their radiosensitivity. Mutagenic effects on two plantlet generation

    International Nuclear Information System (INIS)

    Mahama, Adamou.

    1980-10-01

    This work on textile hibiscus was undertaken for two reasons: to contribute by physical mutagenesis methods to the genetic improvement of these species and especially to obtain the genetic diversity which is seriously lacking in the species sabdariffa var. altissima; to add to research on the effects of mutagenic seed treatments and thus to help towards a better definition of optimum seed irradiation conditions. These two purposes have been fulfilled. The main results may be summed up as follows. - Concerning the improvement of textile hibiscus. Many strains with various new features were selected at the second generation and may lead either to new varieties or at least to interesting precursors for selection programmes. In the second generation derived from Hibiscus saddariffa var. THS 22 some plants were observed with one or more of the following characteristics specific to the edible form: ramified bearing - fleshy calix - smooth leaf. - Concerning the study of mutagenic seed treatment effects. Our experiments showed up the importance of the seed water content and its effect on the response of first-generation plantlets to cobalt 60 γ-ray treatments [fr

  10. Study of radio-restoration by various mineral salts and silice wich products (Tuf and Pouzzolane) of rice embryos (oryza-sativa L, Cigalon variety) exposed to cobalt 60 gamma rays

    International Nuclear Information System (INIS)

    Mouthia-Khadija.

    1981-12-01

    Mutagenic treatments produce a large number of mutants per unit time and are used for plant improvement. However these treatments cause damage to cells. To counteract this radio-induced damage 2 methods are being tried: - Protection, which consists in the supply of an active product before application of mutagenic agents; - Restoration, which tries to repair the damage after mutagenic treatment. This work is devoted to restoration processes. Technique for the isolation and culture on a suitable nutrient of rice embryos (oryza sativa L, Cigalon variety) separated from non-irradiated caryopses were developed first. By separating out the embryo in this way it is possible to study in vitro the interactions between the embryo and the rest of the caryopsis (albumin + pericarp). The effects of radiations on embryos from caryopses exposed to cobalt 60 gamma rays were measured next, then the action of certain inorganic elements contained in the caryopsis tissues was analysed. On the basis of the first results obtained the differences in response between plantlets from embryos irradiated or otherwise treated or not either by zinc sulphate or by very silice-rich volcanic products (Tuf and Pouzzolane), were examined by chemical analysis techniques. These tests have allowed the detection of ionic changes induced by irradiation during the different stages of plant development and led to a better estimate of the radio-restoration mechanisms brought about by the various chemical compounds used [fr

  11. Commissioning dosimetry and in situ dose mapping of a semi-industrial Cobalt-60 gamma-irradiation facility using Fricke and Ceric-cerous dosimetry system and comparison with Monte Carlo simulation data

    Science.gov (United States)

    Mortuza, Md Firoz; Lepore, Luigi; Khedkar, Kalpana; Thangam, Saravanan; Nahar, Arifatun; Jamil, Hossen Mohammad; Bandi, Laxminarayan; Alam, Md Khorshed

    2018-03-01

    Characterization of a 90 kCi (3330 TBq), semi-industrial, cobalt-60 gamma irradiator was performed by commissioning dosimetry and in-situ dose mapping experiments with Ceric-cerous and Fricke dosimetry systems. Commissioning dosimetry was carried out to determine dose distribution pattern of absorbed dose in the irradiation cell and products. To determine maximum and minimum absorbed dose, overdose ratio and dwell time of the tote boxes, homogeneous dummy product (rice husk) with a bulk density of 0.13 g/cm3 were used in the box positions of irradiation chamber. The regions of minimum absorbed dose of the tote boxes were observed in the lower zones of middle plane and maximum absorbed doses were found in the middle position of front plane. Moreover, as a part of dose mapping, dose rates in the wall positions and some selective strategic positions were also measured to carry out multiple irradiation program simultaneously, especially for low dose research irradiation program. In most of the cases, Monte Carlo simulation data, using Monte Carlo N-Particle eXtended code version MCNPX 2.7., were found to be in congruence with experimental values obtained from Ceric-cerous and Fricke dosimetry; however, in close proximity positions from the source, the dose rate variation between chemical dosimetry and MCNP was higher than distant positions.

  12. Cobalt reduction of NSSS valve hardfacings for ALARA

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Joo Hak; Lee, Sang Sub [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of)

    1994-07-01

    This report informs NSSS designer that replacement of materials is one of the major means of ALARA implementation, and describes that NSSS valves with high-cobalt hardfacing are significant contributors to post-shutdown radiation fields caused by activation of cobalt-59 to cobalt-60. Generic procedures for implementing cobalt reduction programs for valves are presented. Discussions are presented of the general and specific design requirements for valve hardfacing in nuclear service. The nuclear safety issues involved with changing valve hardfacing materials are discussed. The common methods used to deposit hardfacing materials are described together with an explanation of the wear measurements. Wear resistance, corrosion resistance, friction coefficient, and mechanical properties of candidate hardfacing alloys are given. World-wide nuclear utility experience with cobalt-free hardfacing alloys is described. The use of low-cobalt or cobalt-free alloys in other nuclear plant components is described. 17 figs., 38 tabs., 18 refs. (Author).

  13. Cobalt reduction of NSSS valve hardfacings for ALARA

    International Nuclear Information System (INIS)

    Kim, Joo Hak; Lee, Sang Sub

    1994-07-01

    This report informs NSSS designer that replacement of materials is one of the major means of ALARA implementation, and describes that NSSS valves with high-cobalt hardfacing are significant contributors to post-shutdown radiation fields caused by activation of cobalt-59 to cobalt-60. Generic procedures for implementing cobalt reduction programs for valves are presented. Discussions are presented of the general and specific design requirements for valve hardfacing in nuclear service. The nuclear safety issues involved with changing valve hardfacing materials are discussed. The common methods used to deposit hardfacing materials are described together with an explanation of the wear measurements. Wear resistance, corrosion resistance, friction coefficient, and mechanical properties of candidate hardfacing alloys are given. World-wide nuclear utility experience with cobalt-free hardfacing alloys is described. The use of low-cobalt or cobalt-free alloys in other nuclear plant components is described. 17 figs., 38 tabs., 18 refs. (Author)

  14. EFTF cobalt test assembly results

    International Nuclear Information System (INIS)

    Rawlins, J.A.; Wootan, D.W.; Carter, L.L.; Brager, H.R.; Schenter, R.E.

    1988-01-01

    A cobalt test assembly containing yttrium hydride pins for neutron moderation was irradiated in the Fast Flux Test Facility during Cycle 9A for 137.7 equivalent full power days at a power level fo 291 MW. The 36 test pins consisted of a batch of 32 pins containing cobalt metal to produce Co-60, and a set of 4 pins with europium oxide to produce Gd-153, a radioisotope used in detection of the bone disease Osteoporosis. Post-irradiation examination of the cobalt pins determined the Co-60 produced with an accuracy of about 5 %. The measured Co-60 spatially distributed concentrations were within 20 % of the calculated concentrations. The assembly average Co-60 measured activity was 4 % less than the calculated value. The europium oxide pins were gamma scanned for the europium isotopes Eu-152 and Eu-154 to an absolute accuracy of about 10 %. The measured europium radioisotpe anc Gd-153 concentrations were within 20 % of calculated values. In conclusion, the hydride assembly performed well and is an excellent vehicle for many Fast Flux Test Facility isotope production applications. The results also demonstrate that the calculational methods developed by the Westinghouse Hanford Company are very accurate. (author)

  15. Cytogenetic effects of protracted exposures to alpha-particles from plutonium-239 and to gamma-rays from cobalt-60 compared in male mice

    International Nuclear Information System (INIS)

    Searle, A.G.; Beechey, C.V.; Green, D.; Humphreys, E.R.

    1976-01-01

    Adult C3HX 101 hybrid male mice were injected intravenously with 4 μCi of 239 Pu citrate per kg body weight and examined for evidence of cytogenetic damage to the testis after exposures of 21, 28 and 34 weeks, with average doses from α-particles estimated as 13, 18 and 18 rad respectively (mean dose rate 0.00006 rad/min). Results were compared with those obtained when equivalent males were exposed continuously and concurrently to 1128 rad 60 Co γ-irradiation over 28 weeks (0.004 rad/min) The following estimates of the relative effectiveness of the α-and γ-radiation were made: 24 for reciprocal translocations and for chromosome fragments, 22 for dominant lethal mutations acting after implantation. These values (with mean of 23) are based on average testis doses, with no correction for probable non-homogeneity of α dose distribution. In the mice exposed to γ-irradiation, there were significant reductions in testis mass and epididymal sperm-count

  16. The Impact of Different Control Techniques of Industrial Irradiation Processing Units (Cobalt 60 Irradiator) on Maintaining Safety for Radiation and Environment

    International Nuclear Information System (INIS)

    Keshek, A. B.

    2010-01-01

    Negative results were caused by fire events inside and outside the industrial irradiation facilities by Co 60 irradiators. It included bad effects on equipment cables, electrical components, product boxes, products, fire detectors radiation detectors various radiation concrete shielding and big volumes of smoke. Big volumes of water and water spray were used to resist and to cool fire inside irradiation facilities. Flooded water was collected on the floor of the irradiation room, it tranced through maze legs to outside the main door and through the electrical tunnels casing big damage outside irradiation unit. The work show two different designs, the first system is the cleaner agent fire suppression by carbon dioxide. CO 2 containers are located outside irradiation concrete facility, and attached by special metallic pipes system. By fire detector and automatic control valves maintain CO 2 to suppress fire inside irradiation room and maintain clean agent fire suppression. The second system depend on Nuclear Regulatory commission C.F.R 10 of 2005 to prevent flooding and trance. The need to design a new system which trances the excessive water from inside irradiation room and to prevent it from escaping to outside irradiation facility during resisting fire by water curtion the excessive water is escaped from the storage pool by electrical pump; the second line will trance the excessive water outside the main building to store inside separated tank

  17. Effect of cobalt-60 γ radiation and of thermal neutrons on high resistance P and N silicon. Possibility of obtaining a nuclear compensation for P type silicon

    International Nuclear Information System (INIS)

    Messier, J.

    1965-11-01

    Type P silicon has been compensated by the production of a controlled and uniform amount of donor atoms ( 31 P) using thermal neutrons to bring about a nuclear transformation. It is shown that it is possible in this way to reduce by a factor of about one hundred the overall concentration of residual ionised impurities in the purest crystals obtained by floating zone purification (2 x 10 12 atoms/cm 3 ). The degree compensation obtained is limited by the initial inhomogeneity of acceptor impurities which have to be compensated. Lattice defects which still remain after prolonged annealings reduce the life-time of the material to about 10 μs approximately. Particle detectors having thicknesses of 2 to 5 mm have been built by this process; they give good results, particularly at low temperatures. A study has also been made of the number and of the nature of lattice defects produced by thermal neutrons in high resistivity P and N type crystals. These defects have been compared to those produced by γ rays from 60 Co. A discussion is given of the validity of the Wertheim model concerning pronounced recombination at low temperatures (77 deg. K - 300 deg. K) of primary defect-interstitial pairs. The nature of the defects introducing energy levels into the lower half of the forbidden band has been studied. (author) [fr

  18. Energy response of imaging plates to radiation beams from standard beta sources, ortho-voltage and cobalt-60 units and linear accelerators

    Science.gov (United States)

    Gonzalez, Albin Leonel

    The response to different types of radiation beams of commercial imaging plates used for diagnostic computed radiography has been investigated in this work. Imaging plates are designed with a phosphor layer which after been irradiated; information is stored in the form of photostimulable luminescence (PSL) centers. Initial measurements of the dose distribution of a radioactive stent with the imaging plates showed similar results to those with radiochromic films, but with much shorter exposure time due to their higher sensitivity. In order to investigate further their response, the imaging plates were irradiated with calibrated beams from: standard beta sources, orthovoltage and Co-60 units and therapy linear accelerator. Initially it was found that the energy to create the storage centers (generation efficiency) when irradiated with the three standard beta sources (225 keV to 2.28 MeV) was the same. For the rest of the calibrated beams an in house reader system was built in order to perform the bleaching of the plates with a He-Ne laser (632.8 nm) and to measure the absolute number of the emitted PSL photons (storage centers produced). Bleaching curves were then obtained for different exposure times for each beam. From the graph of the calculated area under the bleaching curves (total number of storage center) versus the absorbed dose to the phosphor layer it was possible to calculate the energy to create the storage centers (generation efficiency) for photon and electron beams. The dose to the phosphor layer was calculated in the case of the electron beams following a scaling procedure, while in the case of the photon beams Monte Carlo simulations were performed. For the photons beams the measurement of the generation efficiency energy of 126 +/- 8% eV per PSL storage center, coincide with measurements using a different approach (˜148 eV) by previous investigators. The generation efficiency for the electron beam was 807 +/- 3% eV, no reference was found in the

  19. Ionizing radiation effects of Cobalt-60 on the physical-chemical, sensorial and microbiological of bread with addition of linseed (Linum usitatissimum)

    International Nuclear Information System (INIS)

    Moura, Neila Camargo de

    2011-01-01

    The incorporation of functional ingredients on breading products has grown very much lately, because of the preoccupation with the consumers' health. The linseed has awakened the interest by its high level of fiber, lignin, omega-3 and antioxidants compounds. The objective of the present work is evaluate the ionizing radiation effect of 60 Co on the physical-chemical, sensorial and microbiological characteristics of bread with addition of different concentration of brown linseed. There were elaborated 3 types of bread: French roll, form bread prepared with the mixture and form bread produced with conventional ingredients. It was added smashed brown linseed on the bread dough, with concentrations of 8% and 12%. After the preparation, the three kinds of bread packed with polypropylene packages and taken to the IPEN/USP (Institute of Nuclear Energetic Research/University of São Paulo) and irradiated with doses of 6, 8 and 10 kGy. Treatments were elaborated without the addition of linseed and without irradiation, for control, totalizing 12 distinct treatments, to each bread formula tested. Chemical analyses were made (centesimal composition, anti-nutritional compounds, anti-oxidant activity, glycemic index, fat acids, complex B vitamins and minerals); physical analyses (cooking index, volume, color and water activity); sensorial analyses (preference tests and Descriptive Quantitative Analysis - ADQ); microbiological analysis and a survey about irradiated products. It could be seen that the addition of linseed was efficient to increase the level of alimentary fiber and the level of lipids on the 3 bread formula. The three kinds of bread that received the linseed addition and that were not irradiated presented increase on the level of total phenolic; however, when the samples which received the linseed addition were submitted to the irradiation process, it could be noticed the decrease of the antioxidant capacity. There was an increase on the level of omega-3

  20. SU-C-BRC-01: A Monte Carlo Study of Out-Of-Field Doses From Cobalt-60 Teletherapy Units Intended for Historical Correlations of Dose to Normal Tissue

    Energy Technology Data Exchange (ETDEWEB)

    Petroccia, H [University of Florida, Gainesville, FL (United States); Olguin, E [Gainesville, FL (United States); Culberson, W [University of Wisconsin Madison, Madison, WI (United States); Bednarz, B [University of Wisconsin, Madison, WI (United States); Mendenhall, N [UF Health Proton Therapy Institute, Jacksonville, FL (United States); Bolch, W [University Florida, Gainesville, FL (United States)

    2016-06-15

    Purpose: Innovations in radiotherapy treatments, such as dynamic IMRT, VMAT, and SBRT/SRS, result in larger proportions of low-dose regions where normal tissues are exposed to low doses levels. Low doses of radiation have been linked to secondary cancers and cardiac toxicities. The AAPM TG Committee No.158 entitled, ‘Measurements and Calculations of Doses outside the Treatment Volume from External-Beam Radiation Therapy’, has been formed to review the dosimetry of non-target and out-of-field exposures using experimental and computational approaches. Studies on historical patients can provide comprehensive information about secondary effects from out-of-field doses when combined with long-term patient follow-up, thus providing significant insight into projecting future outcomes of patients undergoing modern-day treatments. Methods: We present a Monte Carlo model of a Theratron-1000 cobalt-60 teletherapy unit, which historically treated patients at the University of Florida, as a means of determining doses located outside the primary beam. Experimental data for a similar Theratron-1000 was obtained at the University of Wisconsin’s ADCL to benchmark the model for out-of-field dosimetry. An Exradin A12 ion chamber and TLD100 chips were used to measure doses in an extended water phantom to 60 cm outside the primary field at 5 and 10 cm depths. Results: Comparison between simulated and experimental measurements of PDDs and lateral profiles show good agreement for in-field and out-of-field doses. At 10 cm away from the edge of a 6×6, 10×10, and 20×20 cm2 field, relative out-of-field doses were measured in the range of 0.5% to 3% of the dose measured at 5 cm depth along the CAX. Conclusion: Out-of-field doses can be as high as 90 to 180 cGy assuming historical prescription doses of 30 to 60 Gy and should be considered when correlating late effects with normal tissue dose.

  1. Comparison of humoral immune response, neutralization capacity of anticrotalic serum in young ovines, clinical and weight evaluation between animals inoculated with Crotalus durissus terrificus venom, natural or Cobalt-60-irradiated

    International Nuclear Information System (INIS)

    Ferreira Junior, R.S.

    2005-01-01

    The Elisa technique was used to evaluate and compare the humoral immune response of young ovine to anticrotalic serum production. During serum production, the clinical and weight evaluation of the animals was performed. The parameters utilized were complete blood count, and dosage of urea, creatinine, aspartate aminotransferase, total proteins, albumin and globulin. The animals weight was verified fortnightly during the experiment. The neutralization capacity of the serum produced from the snake Crotalus durissus terrificus natural (NV) and Cobalt-60-irradiated venom (IrV) was evaluated by in vitro challenges. One group of six animals received natural venom, the second group received irradiated venom, and the third was the control group. The animals received six immunizations during 84 days with an interval of 14 days. There was a significant difference (p<5%) in the ELISA test for the profile of the antibodies produced by the experimental groups (NV< IrV). There was no significant difference (p<5%) for biochemical tests, complete blood count, and animals weight between the three groups tested. The group immunized with irradiated venom showed antibodies profile higher than the group immunized with natural venom. The neutralization capacity of the serum produced from the IrV was fivefold higher when compared to the serum produced with NV. The clinical and weight evaluation showed that the o vines in post-weaning phase did not have their physiological profiles altered, and showed an excellent increase in weight during the experimental period. These results indicate a new perspective for the utilization of o vines, aiming the commercial production of anticrotalic serum, which may be applied in the treatment of human and animal envenomation. The cost for its production may be reduced by the posterior utilization of hyperimmunized ovine in human feeding. (author)

  2. Comparison of humoral immune response, neutralization capacity of anticrotalic serum in young ovines, clinical and weight evaluation between animals inoculated with Crotalus durissus terrificus venom, natural or Cobalt-60-irradiated

    Energy Technology Data Exchange (ETDEWEB)

    Ferreira Junior, R.S. E-mail: rseabra@cevap.org.br

    2005-07-01

    The Elisa technique was used to evaluate and compare the humoral immune response of young ovine to anticrotalic serum production. During serum production, the clinical and weight evaluation of the animals was performed. The parameters utilized were complete blood count, and dosage of urea, creatinine, aspartate aminotransferase, total proteins, albumin and globulin. The animals weight was verified fortnightly during the experiment. The neutralization capacity of the serum produced from the snake Crotalus durissus terrificus natural (NV) and Cobalt-60-irradiated venom (IrV) was evaluated by in vitro challenges. One group of six animals received natural venom, the second group received irradiated venom, and the third was the control group. The animals received six immunizations during 84 days with an interval of 14 days. There was a significant difference (p<5%) in the ELISA test for the profile of the antibodies produced by the experimental groups (NV

  3. Cobalt release from inexpensive jewellery

    DEFF Research Database (Denmark)

    Thyssen, Jacob Pontoppidan; Jellesen, Morten Stendahl; Menné, Torkil

    2010-01-01

    . Conclusions: This study showed that only a minority of inexpensive jewellery purchased in Denmark released cobalt when analysed with the cobalt spot test. As fashion trends fluctuate and we found cobalt release from dark appearing jewellery, cobalt release from consumer items should be monitored in the future......Objectives: The aim was to study 354 consumer items using the cobalt spot test. Cobalt release was assessed to obtain a risk estimate of cobalt allergy and dermatitis in consumers who would wear the jewellery. Methods: The cobalt spot test was used to assess cobalt release from all items...

  4. Overview of cobalt-60 external irradiation study

    International Nuclear Information System (INIS)

    Stitzel, K.; Shifrine, M.; Wilson, F.

    1980-01-01

    Work this year has continued to define the immunohematological effects of radiation exposure in Davis beagles over 50 days of age. One case of myeloproliferative disease occurred in one of the animals exposed to 4 R/day, and cases of bone marrow aplasia occurred in the 11 R/day, 4 R/day, and 2 R/day groups. Use of bone marrow transplantation has revealed a profound difference in the mechanism of aplasia induction in dogs which are susceptible to low doses (less than 2000 R exposure at 11 R/day) and dogs which are able to survive in the radiation field for long periods (greater than 3000 R at 11 R/day or 1800 R at 2 R/day). In the latter animals damage occurs to the hematopoietic stromal microenvironment or some other regulatory mechanism which directs the differentiation of the hematopoietic stem cells into the specific end cell pathways (i.e. thrombocytes, red cells neutrophils). In the animals which develop radiation disease after low total exposure, the damage appears to be to the hematopoietic stem cells themselves. This implies that in some animals the stem cells are resistant to massive doses of continuous whole body irradiation, relative to the dose rate

  5. Application gamma radiation of cobalt-60 in disinfestation of some types of rations for feeding small animals; Emprego da radiacao gama do cobalto-60 na desinfestacao de alguns tipos de racoes para alimentacao de animais de pequeno porte

    Energy Technology Data Exchange (ETDEWEB)

    Arthur, Paula Bergamin

    2012-07-01

    The pests as beetles, mites, moths and mushrooms among other, usually infest products stored as: grains, crumbs, flours, coffee, tobacco, dried fruits, animal rations, spices, dehydrated plants, causing the visual depreciation and promoting to deterioration of the products. The present research had as objective the use of the gamma radiation in the disinfestation of some types of rations used for feeding animals of small size. In the first experiment packing of free samples were used measuring 10 cm x 20 cm with capacity of 70 grams of substrate (ration) with 4 types of existent marks in the trade: (1), (2), e (3), and (4). Each treatment consisted of 10 repetitions, that were irradiated with doses of: 0 (control) 0,5; 1,0 and 2,0 kGy, to do the disinfestation of the samples. After the irradiation (disinfestation) of the all irradiated packing and more the control was conditioned in plastic boxes of 80 cm x 50 cm with cover, where the insects were liberated Lasioderma serricorne, Plodia interpuctella, Sitophilus zeamais and Sitophilus oryzae, in a total of 400 for each box and maintained at room acclimatized with 27 {+-} 2 Deg C and relative humidity of 70 {+-} 5%. In the second experiment packing were used made with the materials of packing of the first experiment. Each packing was made of 10 cm x 15 cm, with capacity of 30 grams of substrate (ration). In each repetition was inoculated 10 insects of each species, in a total of 400 insects for experiment per box. The packing with substrate and insect, were stamped in commercial machine and irradiated with doses of: 0 (control) 0,5; 1,0 and 2,0 kGy. The irradiated packing and the control were maintained at room acclimatized same the mentioned in the first experiment. The counting of the number of insects and holes in the packing were made after 60 days. Concluded that only the packing of the ration type number 4 was susceptive to attack of all species of insects. The dose of 0,5 kGy was sufficient to induce the

  6. Dosimetric reevaluation of exposure at working stations of the Mafelec Society. Presence on the production site of elevators push-button containing cobalt 60 between the 21. august and the 7 october 2008; Reevaluation dosimetrique des expositions aux postes de travail de la Societe Mafelec. Presence sur le site de production de poussoirs de boutons et de boutons d'ascenseur contenant du cobalt 60 entre le 21 aout et le 7 octobre 2008

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2008-07-01

    On the 7. october 2008, the public authorities were alerted by the Mafelec society of the detection by their customs services of unusual levels of radioactivity during controls on packages containing elevators push-buttons sent by this society. The first measures made on that very day on the site of the Mafelec society at Chimilin (38) by the mobile cell of radiological intervention of Isere department firemen enlightened the presence of radioactivity in elevators the push-buttons in stainless steel and in complete push-buttons delivered to Mafelec by one or several Indian suppliers. After having made an inspection on the site on the 8. october, the nuclear safety authority requested the help of I.R.S.N. to evaluate the doses received by the facility personnel exposed to these radioactive pieces. The Asn also asked I.R.S.N. to evaluate the public exposure if someone used an elevator equipped with such buttons. The first evaluations showed that 22 persons had received a maximal dose between 1.4 and 2.7 mSv. A second report (on the 27 october 2008) gave a revaluation of the dosimetry and went back to the dosimetric evaluation for a person of the public that would take an elevator with push-buttons containing cobalt 60: scenario: presence of a person during 5 minutes by day in the elevator at 50 cm from the control board and that 300 days by year, for this situation the dose received by a person of the public would be about 150 {mu}Sv. (N.C.)

  7. The use of Gamma radiation of Cobalt-60 to control avocado moth Stenoma catenifer Walsingham, 1912 (Lepidoptera: Elachistidae) and its effects on the quality of the fruit of Persea americana (Miller) (Lauraceae)

    International Nuclear Information System (INIS)

    Silva, Lilian Karla Figueira da

    2004-01-01

    This work aimed to evaluate the influence of Gamma radiation of Cobalt-60, in the avocado moth Stenoma catenifer Walsingham, 1912 (Lepidoptera: Elachistidae) and its effects on the quality of the fruit Persea americana (Miller) (Lauraceae). For this research, insects were irradiated in ali phases of their life cycle with doses varying from O to 600 Gy and they were maintained at the temperature of 25 +- 2 deg C, humidity of 70 +- 10% and photo phase of 14 h. The species was raised on natural diet, avocado seeds. The cultivar fruits Geada were irradiated with doses that varied from 0 to 150 Gy, maintained for 15 days at room temperature (20 a 35 deg C and humidity of 70 - 80 %) and 30 days at a temperature of 10 deg C, humidity of 40 - 60 %. The chemical-physics and sensorial analyses were carried out. According to the obtained results, it was verified that the lethal dose of gamma radiation to S. catenifer eggs, was of 75 Gy; for caterpillars and pupas was of 300 Gy. The sterile-dose for upcoming adults from irradiated S. catenifer eggs was of 25 Gy; for upcoming adults from irradiated caterpillars, it was of 100 Gy; for adults coming from irradiated pupas was of 150 Gy and for irradiated adults was of 200 Gy. The irradiation in the avocado fruit, maintained at room temperature for 7 days of storage, caused change in the coloration of the fruit (dark spots and yellowish coloration) and more firmness. The sensorial characteristics were kept and the irradiated fruit was the chosen one as favorite for tasting. The irradiated fruits that were kept at 10 deg C, obtained an increase in the storage period, without changing their chemical physics characteristics. The coloration of the fruits was kept, more firmness and a subtle acidity taste increase, being effective in the conservation of the fruits and in the maintenance of their sensorial characteristics. The use of the gamma radiation as treatment quarantine of S. catenifer it was efficient, should be treated them with

  8. Study to use graded cobalt adjuster in 540 MWe PHWR

    International Nuclear Information System (INIS)

    Raj, Manish; Fernando, M.P.S.; Pradhan, A.S.; Kumar, A.N.

    2007-01-01

    Full text: There are 17 adjusters in 540 MWe PHWR, which are essentially provided for xenon override function. They also provide flux flattening being in the central region of the reactor core. The present design of adjusters consists of stainless steel tube. The adjuster rods are grouped into 8 banks for movement. Since adjusters are normally fully inserted during reactor operation, they are best suited for production of cobalt 60. The nickel-plated cobalt in the form of either slugs or pellet are used for the design of cobalt pencils. The number of pencils can be varied to optimize the reactivity load and cobalt 60 production requirement. The worth and activity of cobalt adjusters have been worked out considering different pin configuration for the adjuster assembly. To start with we have assumed all adjusters throughout its length are of the same configuration. The flux depression factors within the cobalt pencils have been considered in the estimations of the specific and total cobalt 60 activities. The option of using graded cobalt adjusters, where different pin configuration along the length is considered for better flux flattening

  9. Use of low doses of cobalt 60 gamma radiation on beet (Beta vulgaris L.), carrot (Daucus carota L.) and radish (Raphanus sativus L.) seed to stimulate increase yield; Emprego da radiacao gama do cobalto 60 em sementes de beterraba (Beta vulgaris L.), cenoura (Daucus carota L.) e rabanete (Raphanus sativus L.) para estimular o aumento da producao

    Energy Technology Data Exchange (ETDEWEB)

    Bovi, Jose Eduardo

    2000-07-01

    The research had the aim of evaluating the effects of low doses of Cobalt-60 gamma radiation on seeds of radish (Raphanus sativus L.) cultiva Champion, cultivars Nantes Forto (european origin) and Brasilia (Rio Grande do Sul origin) carrot (Daucus carota L. var. sativus (Hoffm.) Thell), and red beet (Beta vulgaris L.) cultivar Tall Top Early Wonder before sowing, its effects on plant growth, on the yield and roots storage of two tillages: with sowing in the same day of radiation and six days after radiation seeds. The data showed that the seeds radiation did not interfered negatively on plants growth, and the species presented differences as roots production and doses on both plantation: radish with 5,0 Gy and 2,5 Gy doses respectively to the first and the second sowings, Brasilia carrot with 2,5 Gy dose to both sowings. Nantes carrot with 2,5 Gy and 5,0 Gy respectively to the first and the second sowings, and beet with 7,5 Gy and 5,0 Gy respectively to the first and the second plantations. There is not statistics difference by Tukey test (5% and 1%) and none relation between seeds radiation and loss weight on roots storage. (author)

  10. Cobalt sensitization and dermatitis

    DEFF Research Database (Denmark)

    Thyssen, Jacob P

    2012-01-01

    : This clinical review article presents clinical and scientific data on cobalt sensitization and dermatitis. It is concluded that cobalt despite being a strong sensitizer and a prevalent contact allergen to come up on patch testing should be regarded as a very complex metal to test with. Exposure...

  11. Elicitation threshold of cobalt chloride

    DEFF Research Database (Denmark)

    Fischer, Louise A; Johansen, Jeanne D; Voelund, Aage

    2016-01-01

    : On the basis of five included studies, the ED10 values of aqueous cobalt chloride ranged between 0.0663 and 1.95 µg cobalt/cm(2), corresponding to 30.8-259 ppm. CONCLUSIONS: Our analysis provides an overview of the doses of cobalt that are required to elicit allergic cobalt contactdermatitis in sensitized...

  12. Effect of cobalt-60 {gamma} radiation and of thermal neutrons on high resistance P and N silicon. Possibility of obtaining a nuclear compensation for P type silicon; Effects du rayonnement {gamma} du cobalt 60 et de neutrons thermiques sur du silicium P et N de haute resistivite. Possibilite de realiser une compensation nucleaire d'un silicium du type P

    Energy Technology Data Exchange (ETDEWEB)

    Messier, J [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1965-11-01

    Type P silicon has been compensated by the production of a controlled and uniform amount of donor atoms ({sup 31}P) using thermal neutrons to bring about a nuclear transformation. It is shown that it is possible in this way to reduce by a factor of about one hundred the overall concentration of residual ionised impurities in the purest crystals obtained by floating zone purification (2 x 10{sup 12} atoms/cm{sup 3}). The degree compensation obtained is limited by the initial inhomogeneity of acceptor impurities which have to be compensated. Lattice defects which still remain after prolonged annealings reduce the life-time of the material to about 10 {mu}s approximately. Particle detectors having thicknesses of 2 to 5 mm have been built by this process; they give good results, particularly at low temperatures. A study has also been made of the number and of the nature of lattice defects produced by thermal neutrons in high resistivity P and N type crystals. These defects have been compared to those produced by {gamma} rays from {sup 60}Co. A discussion is given of the validity of the Wertheim model concerning pronounced recombination at low temperatures (77 deg. K - 300 deg. K) of primary defect-interstitial pairs. The nature of the defects introducing energy levels into the lower half of the forbidden band has been studied. (author) [French] On a compense du silicium de type P en produisant, au moyen de neutrons thermiques, par transmutation nucleaire une quantite controlee et uniforme d'atomes donneurs ({sup 31}P). On montre qu'on peut ainsi reduire de cent fois environ la densite nette d'impuretes ionisees residuelles subsistant dans les cristaux les plus purs obtenus par purification par zone flottante (2.10{sup 12} atomes/cm{sup 3}). Le degre de compensation obtenu est limite par i'inhomogeneite initiale des impuretes acceptrices a compenser. Des defauts de reseau qui subsistent meme apres des recuits prolonges reduisent la duree de vie du materiau a 10 {mu

  13. Preliminary studies of cobalt complexation in groundwater

    International Nuclear Information System (INIS)

    Warwick, P.; Shaw, P.; Williams, G.M.; Hooker, P.J.

    1988-01-01

    A relatively non-invasive method has been used to separate complexed from free cobalt-60 in groundwater, using the weak cationic adsorption properties of Sephadex gels, and a mobile phase of natural groundwater. Results show the kinetics of Co complex formation in groundwater to be slow, and that the equilibrium position is affected by temperature, cobalt concentration and the ionic/organic strength of the groundwater. The addition of DAEA cellulose to the groundwater to remove humic material, also removed the majority of organic species which absorb UV at 254 nm, but 45% of the original total organic carbon remained, and the amount of complexed cobalt left in solution was only reduced to 76% of its former concentration. This suggests that the completed Co species separated by the method described in this paper are a mixture of inorganic and organic compounds, and studies are therefore continuing to establish their exact nature. (author)

  14. Preliminary studies of cobalt complexation in groundwater

    International Nuclear Information System (INIS)

    Warwick, P.; Shaw, P.; Williams, G.M.; Hooker, P.J.

    1988-01-01

    A relatively non-invasive method has been used to separate complexed from free cobalt-60 in groundwater, using the weak cationic adsorption properties of Sephadex gels, and a mobile phase of natural groundwater. Results show the kinetics of Co complex formation in groundwater to be slow, and that the equilibrium position is affected by temperature, cobalt concentration and the ionic/organic strength of the groundwater. The addition of DEAE cellulose to the groundwater to remove humic material, also removed the majority of organic species with absorb UV at 254 nm, but 45% of the original total organic carbon remained, and the amount of complexed cobalt left in solution was only reduced to 76% of its former concentration. This suggests that the complexed Co species separated by the method described in this paper are a mixture of inorganic and organic compounds, and studies are therefore continuing to establish their exact nature. (orig.)

  15. Influence of the protective cream and synthetic zeolites on the transfer of the 60Co across the skin of rat

    International Nuclear Information System (INIS)

    Kassai, Z.; Koprda, V.; Harangozo, M.; Palinkasova, A.; Bauerova, K.

    2000-01-01

    In this paper the influence of protection cream and synthetic zeolite on the transfer of the cobalt-60 across the skin of rat was examined. Influence of different methods of cream application on kinetics of cobalt-60 permeation is described

  16. The use of Gamma radiation of Cobalt-60 to control avocado moth Stenoma catenifer Walsingham, 1912 (Lepidoptera: Elachistidae) and its effects on the quality of the fruit of Persea americana (Miller) (Lauraceae).; Uso da radiacao gama do Cobalto-60, para controlar a broca-do-abacate Stenoma catenifer Walsingham, 1912 (Lepidoptera: Elachistidae) e seus efeitos na qualidade do fruto de Persea americana (Miller) (Lauraceae)

    Energy Technology Data Exchange (ETDEWEB)

    Silva, Lilian Karla Figueira da

    2004-07-01

    This work aimed to evaluate the influence of Gamma radiation of Cobalt-60, in the avocado moth Stenoma catenifer Walsingham, 1912 (Lepidoptera: Elachistidae) and its effects on the quality of the fruit Persea americana (Miller) (Lauraceae). For this research, insects were irradiated in ali phases of their life cycle with doses varying from O to 600 Gy and they were maintained at the temperature of 25 +- 2 deg C, humidity of 70 +- 10% and photo phase of 14 h. The species was raised on natural diet, avocado seeds. The cultivar fruits Geada were irradiated with doses that varied from 0 to 150 Gy, maintained for 15 days at room temperature (20 a 35 deg C and humidity of 70 - 80 %) and 30 days at a temperature of 10 deg C, humidity of 40 - 60 %. The chemical-physics and sensorial analyses were carried out. According to the obtained results, it was verified that the lethal dose of gamma radiation to S. catenifer eggs, was of 75 Gy; for caterpillars and pupas was of 300 Gy. The sterile-dose for upcoming adults from irradiated S. catenifer eggs was of 25 Gy; for upcoming adults from irradiated caterpillars, it was of 100 Gy; for adults coming from irradiated pupas was of 150 Gy and for irradiated adults was of 200 Gy. The irradiation in the avocado fruit, maintained at room temperature for 7 days of storage, caused change in the coloration of the fruit (dark spots and yellowish coloration) and more firmness. The sensorial characteristics were kept and the irradiated fruit was the chosen one as favorite for tasting. The irradiated fruits that were kept at 10 deg C, obtained an increase in the storage period, without changing their chemical physics characteristics. The coloration of the fruits was kept, more firmness and a subtle acidity taste increase, being effective in the conservation of the fruits and in the maintenance of their sensorial characteristics. The use of the gamma radiation as treatment quarantine of S. catenifer it was efficient, should be treated them with

  17. Cobalt-free nickel-base superalloys

    International Nuclear Information System (INIS)

    Koizumi, Yutaka; Yamazaki, Michio; Harada, Hiroshi

    1979-01-01

    Cobalt-free nickel-base cast superalloys have been developed. Cobalt is considered to be a beneficial element to strengthen the alloys but should be eliminated in alloys to be used for direct cycle helium turbine driven by helium gas from HTGR (high temp. gas reactor). The elimination of cobalt is required to avoid the formation of radioactive 60 Co from the debris or scales of the alloys. Cobalt-free alloys are also desirable from another viewpoint, i.e. recently the shortage of the element has become a serious problem in industry. Cobalt-free Mar-M200 type alloys modified by the additions of 0.15 - 0.2 wt% B and 1 - 1.5 wt% Hf were found to have a creep rupture strength superior or comparable to that of the original Mar-M200 alloy bearing cobalt. The ductility in tensile test at 800 0 C, as cast or after prolonged heating at 900 0 C (the tensile test was done without removing the surface layer affected by the heating), was also improved by the additions of 0.15 - 0.2% B and 1 - 1.5% Hf. The morphology of grain boundaries became intricated by the additions of 0.15 - 0.2% B and 1 - 1.5% Hf, to such a degree that one can hardly distinguish grain boundaries by microscopes. The change in the grain boundary morphology was considered, as suggested previously by one of the authors (M.Y.), to be the reason for the improvements in the creep rupture strength and tensile ductility. (author)

  18. Construction of an apparatus for nuclear orientation measurements at low temperatures. Application to neodymium-cobalt alloy

    International Nuclear Information System (INIS)

    Mayer, E.

    1965-10-01

    We describe experiments along which has been studied the anisotropy of γ radiations emitted by oriented nuclei. We have used the great hyperfine fields acting on nuclei in ferromagnetic metals so as to produce alignment at low temperature. By irradiation we obtained a few cobalt 60 nuclei in our samples which were then cooled down to 0,01 K. The anisotropic rate of the 1,33 MeV γ radiation was measured in function of the sample temperature, using as thermometer the anisotropy of γ radiation emitted by cobalt 60 nuclei in a cobalt single crystal. Cobalt 60 was lined up in a cobalt nickel alloy (40% Ni). The hyperfine field at the cobalt was measured compared to the effective field in metallic cobalt: Heff(Co Ni)/Heff(Co metal) = 0.71 ± 0.12. These results are in good agreement with specific heat measurements made previously. Cobalt 60 has been polarised in a neodymium-cobalt alloy (NdCo 5 ). The field at the cobalt in NdCo 5 has been measured compared to the field in metallic cobalt and taking the non-saturation into account we found 165000 oersteds 5 ) [fr

  19. Cobalt toxicity: Chemical and radiological combined effects on HaCaT keratinocyte cell line

    International Nuclear Information System (INIS)

    Sandre, C.; Moulin, C.; Bresson, C.; Gault, N.; Poncy, J. L.; Lefaix, J. L.

    2010-01-01

    Cobalt (Co) is an essential trace element well known as a constituent of vitamin B 12 , but different compounds of Co are also described as highly toxic and/or radio-toxic for individuals or the environment. In nuclear power plants, 58 Co and 60 Co are radioactive isotopes of cobalt present as activation products of stable Co and Ni used in alloys. Skin exposure is a current occupational risk in the hard metal and nuclear industries. As biochemical and molecular cobalt-induced toxicological mechanisms are not fully identified, we investigated cobalt toxicity in a model human keratinocyte cell line, HaCaT. In this study, we propose a model to determine the in vitro chemical impact on cell viability of a soluble form of cobalt (CoCl 2 ) with or without gamma-ray doses to mimic contamination by 60 Co, to elucidate the mechanisms of cobalt intracellular chemical and radiological toxicity. Intracellular cobalt concentration was determined after HaCaT cell contamination and chemical toxicity was evaluated in terms of cellular viability and clonogenic survival. We investigated damage to DNA in HaCaT cells by combined treatment with chemical cobalt and a moderate gamma-ray dose. Additive effects of cobalt and irradiation were demonstrated. The underlying mechanism of cobalt toxicity is not clearly established, but our results seem to indicate that the toxicity of Co(II) and of irradiation arises from production of reactive oxygen species. (authors)

  20. Cobalt toxicity: Chemical and radiological combined effects on HaCaT keratinocyte cell line

    Energy Technology Data Exchange (ETDEWEB)

    Gault, N. [CEA Fontenay aux Roses, DSV/IRCM/SCSR/LRTS, 92265 Fontenay aux Rose (France); Sandre, C.; Moulin, B.; Bresson, C. [CEA, DEN, SECR, Laboratoire de Speciation des Radionucleides et des Molecules, F-91191 Gif-sur-Yvette (France); Poncy, J.L. [CEA Bruyeres Le Chatel, DSV/IRCM/SREIT/LRT, 91680 Bruyeres Le Chatel (France); Lefaix, J.L. [CEA Caen, DSV/IRCM/SRO/LARIA, 14070 Caen (France)

    2010-07-01

    Cobalt (Co) is an essential trace element well known as a constituent of vitamin B12, but different compounds of Co are also described as highly toxic and/or radio-toxic for individuals or the environment. In nuclear power plants, {sup 58}Co and {sup 60}Co are radioactive isotopes of cobalt present as activation products of stable Co and Ni used in alloys. Skin exposure is a current occupational risk in the hard metal and nuclear industries. As biochemical and molecular cobalt-induced toxicological mechanisms are not fully identified, we investigated cobalt toxicity in a model human keratinocyte cell line, HaCaT. In this study, we propose a model to determine the in vitro chemical impact on cell viability of a soluble form of cobalt (CoCl{sub 2}) with or without {gamma}-ray doses to mimic contamination by {sup 60}Co, to elucidate the mechanisms of cobalt intracellular chemical and radiological toxicity. Intracellular cobalt concentration was determined after HaCaT cell contamination and chemical toxicity was evaluated in terms of cellular viability and clonogenic survival. We investigated damage to DNA in HaCaT cells by combined treatment with chemical cobalt and a moderate {gamma}-ray dose. Additive effects of cobalt and irradiation were demonstrated. The underlying mechanism of cobalt toxicity is not clearly established, but our results seem to indicate that the toxicity of Co(II) and of irradiation arises from production of reactive oxygen species. (authors)

  1. Cobalt toxicity: Chemical and radiological combined effects on HaCaT keratinocyte cell line

    Energy Technology Data Exchange (ETDEWEB)

    Sandre, C.; Moulin, C.; Bresson, C. [CEA Saclay, DEN, SECR, Lab Speciat Radionucleides and Mol, F-91191 Gif Sur Yvette (France); Gault, N. [CEA Fontenay Roses, DSV IRCM SCSR LRTS, F-92265 Fontenay Aux Roses (France); Poncy, J. L. [CEA Bruyeres Le Chatel, DSV IRCM SREIT LRT, F-91680 Bruyeres Le Chatel (France); Lefaix, J. L. [CEA Caen, DSV IRCM SRO LARIA, F-14070 Caen (France)

    2010-07-01

    Cobalt (Co) is an essential trace element well known as a constituent of vitamin B{sub 12}, but different compounds of Co are also described as highly toxic and/or radio-toxic for individuals or the environment. In nuclear power plants, {sup 58}Co and {sup 60}Co are radioactive isotopes of cobalt present as activation products of stable Co and Ni used in alloys. Skin exposure is a current occupational risk in the hard metal and nuclear industries. As biochemical and molecular cobalt-induced toxicological mechanisms are not fully identified, we investigated cobalt toxicity in a model human keratinocyte cell line, HaCaT. In this study, we propose a model to determine the in vitro chemical impact on cell viability of a soluble form of cobalt (CoCl{sub 2}) with or without gamma-ray doses to mimic contamination by {sup 60}Co, to elucidate the mechanisms of cobalt intracellular chemical and radiological toxicity. Intracellular cobalt concentration was determined after HaCaT cell contamination and chemical toxicity was evaluated in terms of cellular viability and clonogenic survival. We investigated damage to DNA in HaCaT cells by combined treatment with chemical cobalt and a moderate gamma-ray dose. Additive effects of cobalt and irradiation were demonstrated. The underlying mechanism of cobalt toxicity is not clearly established, but our results seem to indicate that the toxicity of Co(II) and of irradiation arises from production of reactive oxygen species. (authors)

  2. Use of gamma radiation of Cobalt-60 aiming at the quarentenary treatment and the sterilization of Stenoma catenifer Walsingham (Lepidoptera: Elachistidae); Uso de radiación gamma de Cobalto-60 en tratamiento cuarentenario y esterilización de Stenoma catenifer Walsingham (Lepidoptera: Elachistidae)

    Energy Technology Data Exchange (ETDEWEB)

    Silva, L. K.F.; Arthur, V.; Nava, D. E.; Parra, J. R.P.

    2007-07-15

    The objective of this work was verify the influence of gamma radiation of Cobalt-60, in the avocado moth Stenoma catenifer Walsingham (Lepidoptera: Elachistidae). For this research, insects were irradiated in all phases of their life cycle with doses varying from 0 to 600 Gy and they were maintained at the temperature of 25 +/- 2 deg C, relative humidity of 70 +/- 10% and photofase of 14 h. The species was reared on natural diet, avocado seeds, variety Breda. According to the obtained results, was verified that the lethal dose of gamma radiation to S. catenifer larvae and pupae was of 300 Gy. The sterile dose for upcoming adults from irradiated S. catenifer larvae, was of 100 Gy; for adults coming from irradiated pupas was of 150 Gy and for irradiated adults was of 200 Gy. The use the gamma radiation as treatment quarentine of S. catenifer was efficient, should be treated them with doses able to promote the sterilization of insect, without committing your qualities physical-chemistries and sensorial of fruits. Therefore, is suggested the treatment with the dose of 50 Gy for fruits infested with eggs and 150 Gy for fruits infested with larvae and pupas of S. catenifer. For use the sterile insect technique is recommended the irradiation of pupas and adults with doses of 150 Gy and 200 Gy, respectively [Portuguese] O objetivo deste trabalho foi verificar a influência da radiação gama Cobalto-60, na broca-do-abacate, Stenoma catenifer Walsingham (Lepidoptera: Elachistidae) como subsídio a tratamentos quarentenários e para aplicação da técnica do inseto estéril. Para isso, foram irradiados insetos, em todas as fases do ciclo de vida, com doses que variaram de 0 a 600 Gy e mantidos à temperatura de 25 ± 2º C; umidade relativa de 70 ± 10% e fotofase de 14 h. A espécie, foi criada em dieta natural, ou seja, sementes de abacate, cultivar Breda. De acordo com os resultados obtidos, verificou-se que a dose letal de radiação gama para lagartas e pupas de S

  3. Concentration of radioactive cobalt by seaweeds in the food chain

    International Nuclear Information System (INIS)

    Nakahara, Motokazu; Koyanagi, Taku; Saiki, Masamichi

    1976-01-01

    On the pathway of radioactive substances in marine environments, seaweeds play an important role because of their higher concentration factors for many radionuclides and because they constitute a link of food chain in the sea. In the present work, uptake, distribution and excretion of radioactive cobalt were studied on several kinds of seaweeds by radioisotope tracer experiments under laboratory conditions and concentration factors were calculated. The concentration factors were also estimated from the results of stable cobalt determination by activation analysis or atomic absorption spectrometry on seaweeds and seawater, and compared with the results of tracer expts. The seaweeds showed the species specificity for the concentration of stable and radioactive cobalt with diverse values of concentration factors and biological half-lives. The transfer of radioactive cobalt in the food chain from contaminated seaweeds to mollusca was examined by feeding abalones, Haliotis discus, with four kinds of seaweed labelled with 60 Co and observing retention. Absorption rate for radioactive cobalt by abalones calculated at two days after feeding showed diverse values depending upon the species of seaweed, as follows: 47% through Laminaria japonica and Ulva pertusa, 31% through Undaria pinnatifida and 26 through Eisenia bicyclis, respectively. From the results, it was assumed that the accumulation of radioactive cobalt by mollusca is affected by the species of seaweeds as food. A very high concentration of ingested radioactive cobalt in the midgut gland was seen on the autoradiograph of abalone samples. (auth.)

  4. Concentration of radioactive cobalt by seaweeds in the food chain

    International Nuclear Information System (INIS)

    Nakahara, M.; Koyanagi, T.; Saiki, M.

    1975-01-01

    On the pathway of radioactive substances in marine environments, seaweeds play an important role because of their higher concentration factors for many radionuclides and because they constitute a link in the food chain. In the present work, uptake, distribution and excretion of radioactive cobalt were studied on several kinds of seaweeds by radioisotope tracer experiments under laboratory conditions and concentration factors were calculated. The concentration factors were also estimated from the results of stable cobalt determination by activation analysis or atomic absorption spectrometry on seaweeds and seawater, and compared with the results of tracer experiments. The seaweeds showed the species specificity for the concentration of stable and radioactive cobalt with diverse values of concentration factors and biological half-lives. The transfer of radioactive cobalt in the food chain from contaminated seaweeds to mollusca was examined by feeding abalones, Haliotis discus, with four kinds of seaweed labelled with 60 Co and observing retention. Absorption rate for radioactive cobalt by abalones calculated at two days after feeding showed diverse values depending upon the species of seaweed, as follows: 47% through Laminaria japonica and Ulva pertusa, 31% through Undaria pinnatifida and 26% through Eisenia bicyclis, respectively. From the results, it was assumed that the accumulation of radioactive cobalt by mollusca is affected by the species of seaweeds as food. A very high concentration of ingested radioactive cobalt in the midgut gland was seen on the autoradiograph of abalone samples. (author)

  5. Manganese substituted cobalt ferrite magnetostrictive materials for magnetic stress sensor applications

    OpenAIRE

    Paulsen, J. A.; Ring, A. P.; Lo, C. C. H.; Snyder, John Evan; Jiles, David

    2005-01-01

    Metal bonded cobalt ferrite composites have been shown to be promising candidate materials for use in magnetoelastic stress sensors, due to their large magnetostriction and high sensitivity of magnetization to stress. However previous results have shown that below 60 °C the cobalt ferrite material exhibits substantial magnetomechanical hysteresis. In the current study, measurements indicate that substituting Mn for some of the Fe in the cobalt ferrite can lower the Curie temperature of the ma...

  6. cobalt (ii), nickel (ii)

    African Journals Online (AJOL)

    DR. AMINU

    Department of Chemistry Bayero University, P. M. B. 3011, Kano, Nigeria. E-mail: hnuhu2000@yahoo.com. ABSTRACT. The manganese (II), cobalt (II), nickel (II) and .... water and common organic solvents, but are readily soluble in acetone. The molar conductance measurement [Table 3] of the complex compounds in.

  7. The cobalt radioactive isotopes in environment

    International Nuclear Information System (INIS)

    2007-01-01

    For the year 1993 the total activity released in cobalt is 69 GBq for the whole of nuclear power plants. The part of activity in cobalt for La Hague in 1993 is 8 GBq of 58 Co and 2 GBq of 60 Co. The radioactive isotopes released by nuclear power plants or the reprocessing plant of La Hague under liquid effluents are shared by half between 58 Co and 60 Co. The exposure to sealed sources is the most important risk for the cobalt. The risk of acute exposure can associate a local irradiation of several decades of grays inducing a radiological burns, deep burn to treat in surgery by resection or graft even amputation. A global irradiation of organism for several grays induces an acute irradiation syndrome, often serious. At long term the stochastic effects are represented by leukemia and radio-induced cancers. The increase of probability of their occurrence is 1% by sievert. We must remind that the natural spontaneous probability is 25%. (N.C.)

  8. Separation of cobalt from synthetic intermediate and decontamination radioactive wastes using polyurethane foam

    International Nuclear Information System (INIS)

    Rao, S.V.S.; Lal, K.B.; Narasimhan, S.V.; Ahmed, J.

    1997-01-01

    Studies have been carried out on the removal of radioactive cobalt ( 60 Co) from synthetic intermediate level waste (ILW) and decontamination waste using neat polyurethane (PU) foam as well as n-tributyl phosphate-polyurethane (TBP-PU) foam. The radioactive cobalt has been extracted on the PU foam as cobalt thiocyanate from the ILW. Maximum removal of cobalt has been observed when the concentration of thiocyanate in the solution is about 0.4 M. Cobalt can be separated from decontamination waste containing ethylenediaminetetraacetic acid (EDTA) and iron(II). The extent of extraction of cobalt is slow and the separation of iron and cobalt is better with the neat PU foam compared to the TBP-PU foam. The presence of iron in the decontamination waste facilitates the extraction of cobalt thiocyanate on the PU foam. Column studies have been carried out in order to extend these studies to the plant scale. The capacities of the PU foams for cobalt have been determined. The effect of density and the surface area of PU foam have been investigated. Fourier Transform Infrared (FT-IR) spectral studies have been conducted to find out the interaction between PU foam and cobalt thiocyanate species

  9. Feasibility of magnetic resonance imaging-guided liver stereotactic body radiation therapy: A comparison between modulated tri-cobalt-60 teletherapy and linear accelerator-based intensity modulated radiation therapy.

    Science.gov (United States)

    Kishan, Amar U; Cao, Minsong; Wang, Pin-Chieh; Mikaeilian, Argin G; Tenn, Stephen; Rwigema, Jean-Claude M; Sheng, Ke; Low, Daniel A; Kupelian, Patrick A; Steinberg, Michael L; Lee, Percy

    2015-01-01

    The purpose of this study was to investigate the dosimetric feasibility of liver stereotactic body radiation therapy (SBRT) using a teletherapy system equipped with 3 rotating (60)Co sources (tri-(60)Co system) and a built-in magnetic resonance imager (MRI). We hypothesized tumor size and location would be predictive of favorable dosimetry with tri-(60)Co SBRT. The primary study population consisted of 11 patients treated with SBRT for malignant hepatic lesions whose linear accelerator (LINAC)-based SBRT plans met all mandatory Radiation Therapy Oncology Group (RTOG) 1112 organ-at-risk (OAR) constraints. The secondary study population included 5 additional patients whose plans did not meet the mandatory constraints. Patients received 36 to 60 Gy in 3 to 5 fractions. Tri-(60)Co system SBRT plans were planned with ViewRay system software. All patients in the primary study population had tri-(60)Co SBRT plans that passed all RTOG constraints, with similar planning target volume coverage and OAR doses to LINAC plans. Mean liver doses and V10Gy to the liver, although easily meeting RTOG 1112 guidelines, were significantly higher with tri-(60)Co plans. When the 5 additional patients were included in a univariate analysis, the tri-(60)Co SBRT plans were still equally able to pass RTOG constraints, although they did have inferior ability to pass more stringent liver and kidney constraints (P < .05). A multivariate analysis found the ability of a tri-(60)Co SBRT plan to meet these constraints depended on lesion location and size. Patients with smaller or more peripheral lesions (as defined by distance from the aorta, chest wall, liver dome, and relative lesion volume) were significantly more likely to have tri-(60)Co plans that spared the liver and kidney as well as LINAC plans did (P < .05). It is dosimetrically feasible to perform liver SBRT with a tri-(60)Co system with a built-in MRI. Patients with smaller or more peripheral lesions are more likely to have optimal liver

  10. Estimation of cobalt release from feed water heater tubes of BWRs

    International Nuclear Information System (INIS)

    Uchida, S.; Kitamura, M.; Ozawa, Y.

    1983-01-01

    To evaluate the release source of cobalt from heater tubes of the feed water line, release rate measurements were carried out by detecting 60 Co released from irradiated stainless steel in contact with neutral water at an oxygen concentration of 20 ppb. The dependences of cobalt release rate on temperature, flow velocity and exposure time were studied after 670 hours of release experiments, and an empirical equation (which is presented) was obtained in the temperature range from 150 to 240 deg C. A decrease in the cobalt release rate above 250 deg C was considered due to the formation of a protective oxide layer. From these data, the amount of cobalt released from individual feed water heaters was evaluated. It was demonstrated that low cobalt containing stainless steel was economically applied only in the higher temperature region of the heater (20% of the total surface) to reduce cobalt feed rate into the reactor (to approx. 1/2). (author)

  11. Heating analysis of cobalt adjusters in reactor core

    International Nuclear Information System (INIS)

    Mei Qiliang; Li Kang; Fu Yaru

    2011-01-01

    In order to produce 60 Co source for industry and medicine applications in CANDU-6 reactor, the stainless steel adjusters were replaced with the cobalt adjusters. The cobalt rod will generate the heat when it is irradiated by neutron and γ ray. In addition, 59 Co will be activated and become 60 Co, the ray released due to 60 Co decay will be absorbed by adjusters, and then the adjusters will also generate the heat. So the heating rate of adjusters to be changed during normal operation must be studied, which will be provided as the input data for analyzing the temperature field of cobalt adjusters and the relative heat load of moderator. MCNP code was used to simulate whole core geometric configuration in detail, including reactor fuel, control rod, adjuster, coolant and moderator, and to analyze the heating rate of the stainless steel adjusters and the cobalt adjusters. The maximum heating rate of different cobalt adjuster based on above results will be provided for the steady thermal hydraulic and accident analysis, and make sure that the reactor is safe on the thermal hydraulic. (authors)

  12. Investigation of the effect of temperature, dose rate and short-term post-irradiation change on the response of various types of dosimeters to cobalt-60 gamma radiation for quality assurance in Thailand

    International Nuclear Information System (INIS)

    Biramontri, S.

    2000-01-01

    The influences of combined effect of irradiation temperature from -80 deg. C to 60 deg. C and dose rate between 0.2 and 4 Gy/s on the gamma ray response of several commercial routine dosimeters (Harwell Red 4034, Gammachrome YR, FWT-60-00 radiochromic films, FWT-70-40 optical waveguides, GafChromic films, and Fuji CTA-FTR-125 films) were investigated for quality assurance in radiation processes. Besides, the studies of short term post-irradiation stability for the period of 2 h to 7 days are also presented. The overall results indicate the need for a calibration protocol under conditions of use. (author)

  13. Blood doping by cobalt. Should we measure cobalt in athletes?

    Directory of Open Access Journals (Sweden)

    Guidi Gian

    2006-07-01

    Full Text Available Abstract Background Blood doping is commonplace in competitive athletes who seek to enhance their aerobic performances through illicit techniques. Presentation of the hypothesis Cobalt, a naturally-occurring element with properties similar to those of iron and nickel, induces a marked and stable polycythemic response through a more efficient transcription of the erythropoietin gene. Testing the hypothesis Although little information is available so far on cobalt metabolism, reference value ranges or supplementation in athletes, there is emerging evidence that cobalt is used as a supplement and increased serum concentrations are occasionally observed in athletes. Therefore, given the athlete's connatural inclination to experiment with innovative, unfair and potentially unhealthy doping techniques, cobalt administration might soon become the most suited complement or surrogate for erythropoiesis-stimulating substances. Nevertheless, cobalt administration is not free from unsafe consequences, which involve toxic effects on heart, liver, kidney, thyroid and cancer promotion. Implications of the hypothesis Cobalt is easily purchasable, inexpensive and not currently comprehended within the World Anti-Doping Agency prohibited list. Moreover, available techniques for measuring whole blood, serum, plasma or urinary cobalt involve analytic approaches which are currently not practical for antidoping laboratories. Thus more research on cobalt metabolism in athletes is compelling, along with implementation of effective strategies to unmask this potentially deleterious doping practice

  14. Uptake of radionuclides caesium and cobalt

    International Nuclear Information System (INIS)

    Lukac, P.; Foldesova, M.

    1995-01-01

    By means of chemical treatment ammonium, potassium, sodium and H-form of zeolite were prepared. The chemical modifications of zeolite were carried out with: 2M solution of NaNO 3 , NH 4 NO 3 , KNO 3 ; 0,1M solution of HCl; NaOH solution of different concentration. The method of model radioactive solution was used to find the sorption ability for cesium and cobalt every modified zeolite. The model solution were 0.05M solution of cobalt labelled by 60 Co or cesium labelled by 137 Cs. The highest sorption ability was observed for zeolite modified by NaOH. The influence of pH on uptake of cesium and cobalt by modified zeolite was searched as well. The experimental data (leaching tests, compressive strength measurement and porosity) were measured for the case the Cs and Cs from model water solution and radioactive waste water were up taken on chemically modified zeolite and were subsequently incorporated into cement casts on blast furnace cement slags basis. The leachability was tested in water, in basis solution and in acid solution. The leachability in water and basic solution was negligible, in acid solution it was less than 4% which is inside of value of applied measure method. The compressive strength, porosity and leaching experiment are hopefully and show good mechanical stability and good retention of observed radionuclides in samples exposed in leaching solutions. (J.K.)

  15. Uptake of radionuclides caesium and cobalt

    Energy Technology Data Exchange (ETDEWEB)

    Lukac, P; Foldesova, M [Slovak Technical Univ., Bratislava (Slovakia)

    1996-12-31

    By means of chemical treatment ammonium, potassium, sodium and H-form of zeolite were prepared. The chemical modifications of zeolite were carried out with: 2M solution of NaNO{sub 3}, NH{sub 4}NO{sub 3}, KNO{sub 3}; 0,1M solution of HCl; NaOH solution of different concentration. The method of model radioactive solution was used to find the sorption ability for cesium and cobalt every modified zeolite. The model solution were 0.05M solution of cobalt labelled by {sup 60}Co or cesium labelled by {sup 137}Cs. The highest sorption ability was observed for zeolite modified by NaOH. The influence of pH on uptake of cesium and cobalt by modified zeolite was searched as well. The experimental data (leaching tests, compressive strength measurement and porosity) were measured for the case the Cs and Cs from model water solution and radioactive waste water were up taken on chemically modified zeolite and were subsequently incorporated into cement casts on blast furnace cement slags basis. The leachability was tested in water, in basis solution and in acid solution. The leachability in water and basic solution was negligible, in acid solution it was less than 4% which is inside of value of applied measure method. The compressive strength, porosity and leaching experiment are hopefully and show good mechanical stability and good retention of observed radionuclides in samples exposed in leaching solutions. (J.K.).

  16. Nickel, cobalt, and their alloys

    CERN Document Server

    2000-01-01

    This book is a comprehensive guide to the compositions, properties, processing, performance, and applications of nickel, cobalt, and their alloys. It includes all of the essential information contained in the ASM Handbook series, as well as new or updated coverage in many areas in the nickel, cobalt, and related industries.

  17. Utilisation of gamma radiation of Cobalt-60 as quarantine treatment of medicinal plant, aromatic and seasoning plants dehydrated infested by Lasioderma serricorne (Fabricius, 1792) (Coleoptera, Anobiidae) and Plodia interpunctella (Hubner, 1813) (Lepidoptera, Pyralidae)

    International Nuclear Information System (INIS)

    Alves, Juliana Nazare

    2007-01-01

    The research had as objective the use of the gamma radiation of the Cobalto-60 as quarantine treatment of the medicinal plant, aromatic and seasoning plants dehydrated infested by Lasioderma serricorne and Plodia interpunctella determining the disinfestation doses to attend the criterion in the not emergency of adults of the species in study and analysing through the Chromatography of Thin Layer the effect of the gamma radiation of the cobalto-60 on the active principle of extract dehydrated of Chamomilla recutita, Pimpinella anisum, Origanum vulgare, Cymbopogon citratus, Ocimum basilicum and Thymus vulgaris. The work was developed in the Laboratorio de Inseticidas in the Instituto Biologico in Sao Paulo in the period of August of 2005 the June of 2007. The radiation source used gamma was an experimental irradiator of Cobalto-60, model Gamacell 220, located in the Instituto de Pesquisas Energeticas e Nucleares - IPEN, located in Sao Paulo. In the period of 30 days after the irradiation of the samples evaluated the number of adults emerged of Lasioderma serricorne and Plodia interpunctella, using the data of mortality for the analysis of Probit. Obtained 100% of not emergency of adults in the Lasioderma serricorne with the dose of 2,00 kGy and 100% of not emergency of adults in the Plodia interpunctella with the dose of 2,25 kGy. The Chromatographic Analysis of Thin Layer was to evaluate did not show chemical differences in the extracts analysed. (author)

  18. Cobalt source calibration

    International Nuclear Information System (INIS)

    Rizvi, H.M.

    1999-01-01

    The data obtained from these tests determine the dose rate of the two cobalt sources in SRTC. Building 774-A houses one of these sources while the other resides in room C-067 of Building 773-A. The data from this experiment shows the following: (1) The dose rate of the No.2 cobalt source in Building 774-A measured 1.073 x 10 5 rad/h (June 17, 1999). The dose rate of the Shepherd Model 109 Gamma cobalt source in Building 773-A measured 9.27 x 10 5 rad/h (June 25, 1999). These rates come from placing the graduated cylinder containing the dosimeter solution in the center of the irradiation chamber. (2) Two calibration tests in the 774-A source placed the graduated cylinder with the dosimeter solution approximately 1.5 inches off center in the axial direction. This movement of the sample reduced the measured dose rate 0.92% from 1.083 x 10 5 rad/h to 1.073 x 10 5 rad/h. and (3) A similar test in the cobalt source in 773-A placed the graduated cylinder approximately 2.0 inches off center in the axial direction. This change in position reduced the measured dose rate by 10.34% from 1.036 x 10 6 to 9.27 x 10 5 . This testing used chemical dosimetry to measure the dose rate of a radioactive source. In this method, one determines the dose by the chemical change that takes place in the dosimeter. For this calibration experiment, the author used a Fricke (ferrous ammonium sulfate) dosimeter. This solution works well for dose rates to 10 7 rad/h. During irradiation of the Fricke dosimeter solution the Fe 2+ ions ionize to Fe 3+ . When this occurs, the solution acquires a slightly darker tint (not visible to the human eye). To determine the magnitude of the change in Fe ions, one places the solution in an UV-VIS Spectrophotometer. The UV-VIS Spectrophotometer measures the absorbency of the solution. Dividing the absorbency by the total time (in minutes) of exposure yields the dose rate

  19. Unithiol - a cobalt antidote

    International Nuclear Information System (INIS)

    Cherkes, A.I.; Braver-Chernobul'skaya, B.S.

    1977-06-01

    The blockade of the sulfhydryl groups of the proteins leads to a disturbance of the normal activity of many enzymes and thus of the functioning of the organs and tissue. The search for antidotes against these substances which inactivate the enzymes led to the synthesis of a large group of thiols in the Ukrainian Scientific Research Sanitary Chemical Institute. The most active is sodium dithiol-2,3-dimercaptonpropansulphonate CH 2 SH-CHSH-CH 2 SO 3 Na x H 2 O, named unithiol. Its antidote activity is discussed in detail, especially concerning cobalt intoxication. (HK) [de

  20. Testing of cobalt-free alloys for valve applications using a special test loop

    International Nuclear Information System (INIS)

    Benhamou, C.

    1992-01-01

    Considering that use of cobalt alloys should be avoided as far as possible in PWR components, a programme aimed at establishing the performance of cobalt-free alloys has been performed for valve applications, where cobalt alloys are mainly used. Referring to past work, two types of cobalt-free alloys were selected: Ni-Cr-B-Si and Ni-Cr-Fe alloys. Cobalt-free valves' behaviour has been evaluated comparatively with cobalt valves by implementation of a programme in a special PWR test loop. At the issue of the loop test programme, which included endurance, thermal shock and erosion tests, cobalt-free alloys candidate to replace cobalt alloys are proposed in relation with valve type (globe valve and swing check valve). The following was established: (i) Colmonoy 4-26 (Ni-Cr-B-Si alloy) and Cenium Z20 (Ni-Cr-Fe alloy) deposited by plasma arc process were found suitable for use in 3inch swing check valves; (ii) for integral parts acting as guide rings, Nitronic 60 and Cesium Z20/698 were tested successfully; (iii) for small-bore components such as 2inch globe valves, no solution can yet be proposed; introduction of cobalt-free alloys is dependent on the development of automatic advanced arc surfacing techniques applied to small-bore components

  1. The cobalt radioactive isotopes in environment; Les isotopes radioactifs du cobalt dans l'environnement

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2007-07-01

    For the year 1993 the total activity released in cobalt is 69 GBq for the whole of nuclear power plants. The part of activity in cobalt for La Hague in 1993 is 8 GBq of {sup 58}Co and 2 GBq of {sup 60}Co. The radioactive isotopes released by nuclear power plants or the reprocessing plant of La Hague under liquid effluents are shared by half between {sup 58}Co and {sup 60}Co. The exposure to sealed sources is the most important risk for the cobalt. The risk of acute exposure can associate a local irradiation of several decades of grays inducing a radiological burns, deep burn to treat in surgery by resection or graft even amputation. A global irradiation of organism for several grays induces an acute irradiation syndrome, often serious. At long term the stochastic effects are represented by leukemia and radio-induced cancers. The increase of probability of their occurrence is 1% by sievert. We must remind that the natural spontaneous probability is 25%. (N.C.)

  2. Standard Test Method for Application of Ionization Chambers to Assess the Low Energy Gamma Component of Cobalt-60 Irradiators Used in Radiation-Hardness Testing of Silicon Electronic Devices

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 Low energy components in the photon energy spectrum of Co-60 irradiators lead to absorbed dose enhancement effects in the radiation-hardness testing of silicon electronic devices. These low energy components may lead to errors in determining the absorbed dose in a specific device under test. This method covers procedures for the use of a specialized ionization chamber to determine a figure of merit for the relative importance of such effects. It also gives the design and instructions for assembling this chamber. 1.2 This method is applicable to measurements in Co-60 radiation fields where the range of exposure rates is 7 × 10 −6 to 3 × 10−2 C kg −1 s−1 (approximately 100 R/h to 100 R/s). For guidance in applying this method to radiation fields where the exposure rate is >100 R/s, see Appendix X1. Note 1—See Terminology E170 for definition of exposure and its units. 1.3 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information onl...

  3. Cobalt deposition studies in the primary circuit under BWR conditions (Phase 1 and 2)

    International Nuclear Information System (INIS)

    Bennett, Peter

    1996-04-01

    This report presents the results from the first 2 phases of an experiment performed to investigate the effects of water chemistry on cobalt transport and deposition in the primary circuit under BWR conditions. Two high pressure water loops have been used to compare the incorporation of cobalt into the oxide films on coupons of various LWR primary circuit constructional materials, with several pretreatments, under Hydrogen Water Chemistry (HWC) and Normal Water Chemistry (NWC) conditions. Cobalt-60 deposition rates onto samples that had been pre-oxidised in air were lower than on samples that had been exposed previously in a water loop or had untreated surfaces. In NWC, oxide layers were thicker, normalised Co-60 deposition rates were higher and Co-60 activities per unit volume of oxide were greater. Some evidence has been produced to support the conclusions of other workers that a chromium-rich outer oxide layer is responsible for enhanced cobalt incorporation. (author)

  4. Construction of an apparatus for nuclear orientation measurements at low temperatures. Application to neodymium-cobalt alloy; Realisation d'un appareil pour des mesures d'orientation nucleaire a basse temperature. Application a l'alliage neodyme-cobalt

    Energy Technology Data Exchange (ETDEWEB)

    Mayer, E [Commissariat a l' Energie Atomique, Grenoble (France). Centre d' Etudes Nucleaires

    1965-10-01

    We describe experiments along which has been studied the anisotropy of {gamma} radiations emitted by oriented nuclei. We have used the great hyperfine fields acting on nuclei in ferromagnetic metals so as to produce alignment at low temperature. By irradiation we obtained a few cobalt 60 nuclei in our samples which were then cooled down to 0,01 K. The anisotropic rate of the 1,33 MeV {gamma} radiation was measured in function of the sample temperature, using as thermometer the anisotropy of {gamma} radiation emitted by cobalt 60 nuclei in a cobalt single crystal. Cobalt 60 was lined up in a cobalt nickel alloy (40% Ni). The hyperfine field at the cobalt was measured compared to the effective field in metallic cobalt: Heff(Co Ni)/Heff(Co metal) = 0.71 {+-} 0.12. These results are in good agreement with specific heat measurements made previously. Cobalt 60 has been polarised in a neodymium-cobalt alloy (NdCo{sub 5}). The field at the cobalt in NdCo{sub 5} has been measured compared to the field in metallic cobalt and taking the non-saturation into account we found 165000 oersteds < Heff(NdCo{sub 5}) < 220000 oersteds. (author) [French] Nous decrivons des experiences au cours desquelles nous avons etudie l'anisotropie de rayonnements {gamma} emis par des noyaux orientes. Nous avons utilise les grands champs hyperfins agissant sur las noyaux dans les metaux ferromagnetiques pour produire l'alignement a basse temperature. Par irradiation nous avons obtenu quelques noyaux de cobalt 60 dans nos echantillons qui furent ensuite refroidis a 0,01 K. Le degre d'anisotropie du rayonnement {gamma} de 1,33 MeV fut mesure en fonction de la temperature de l'echantillon en utilisant l'anisotropie du rayonnement {gamma} de noyaux de cobalt 60 dans un monocristal de cobalt metallique utilise comme thermometre. Le cobalt 60 a ete aligne dans un alliage de cobalt-nickel (40% Ni). Le champ hyperfin au niveau du cobalt a ete mesure par rapport au champ effectif dans le cobalt metallique

  5. Effect of Cobalt Supplementation on Performance of growing Calves

    Directory of Open Access Journals (Sweden)

    V.Nagabhushana

    Full Text Available The experiment was conducted to study the effect of critical supplementation of wheat straw with cobalt on fibre utilization and nutrient utilization in growing cross-bred male calves. Twenty-one crossbred (HF X Local male growing calves of 3-4 months age were fed with wheat straw based diet consisting without (Co0 and with 1 (Co1 and 6 (Co6 ppm cobalt as cobaltous chloride. There was no significant difference in intake of wheat straw, concentrate and DMI between the three groups and the ratio between concentrate and wheat straw was maintained at 40:60 irrespective of dietary level of cobalt. Similarly, average cumulative body weight, net gain in body weight or feed efficiency did not differ significantly between treatments. No significant effect was observed on the digestibility of dry matter, organic matter, crude protein, ether extract and fibre constituents like NDF, ADF, hemicellulose or cellulose by supplementation of 1 and 6 ppm Co to the diet of growing calves. Balance of nutrients such as Nitrogen, Calcium and Phosphorus was similar and positive in all the treatment groups. TDN and DCP values of the experimental diets remained almost similar irrespective of dietary level of cobalt. [Veterinary World 2008; 1(10.000: 299-302

  6. An analysis of cobalt irradiation in CANDU 6 reactor core

    International Nuclear Information System (INIS)

    Gugiu, E.D.; Dumitrache, I.

    2003-01-01

    In CANDU reactors, one has the ability to replace the stainless steel adjuster rods with neutronically equivalent Co assemblies with a minimum impact on the power plant safety and efficiency. The 60 Co produced by 59 Co irradiation is used extensively in medicine and industry. The paper mainly describes some of the reactor physics and safety requirements that must be carried into practice for the Co adjuster rods. The computations related to the neutronically equivalence of the stainless steel adjusters with the Co adjuster assemblies, as well as the estimations of the activity and the heating of the irradiated cobalt rods are performed using the Monte Carlo codes MCNP5 and MONTEBURNS2.1. The 60 Co activity and heating evaluations are closely related to the neutronics computations and to the density evolution of cobalt isotopes during assumed in-core irradiation period. Unfortunately, the activities of these isotopes could not be evaluated directly using the burn-up capabilities of the MONTEBURNS code because of the lack of their neutron cross-section from the MCNP5 code library. Additional MCNP5 runs for all the cobalt assemblies have been done in order to compute the flux-spectrum, the 59 Co and the 60 Co radiative capture reaction rates in the adjusters. The 60m Co cross-section was estimated using the flux-spectrum and the ORIGEN2.1 code capabilities THERM and RES. These computational steps allowed the evaluation of the one-group cross-section for the radiative capture reactions of cobalt isotopes. The values obtained replaced the corresponding ones from the ORIGEN library, which have been estimated using the flux-spectrum specific to the fuel. The activity values are used to evaluate the dose at the surface of the device designed to transport the cobalt adjusters. (authors)

  7. Cobalt: for strength and color

    Science.gov (United States)

    Boland, Maeve A.; Kropschot, S.J.

    2011-01-01

    Cobalt is a shiny, gray, brittle metal that is best known for creating an intense blue color in glass and paints. It is frequently used in the manufacture of rechargeable batteries and to create alloys that maintain their strength at high temperatures. It is also one of the essential trace elements (or "micronutrients") that humans and many other living creatures require for good health. Cobalt is an important component in many aerospace, defense, and medical applications and is a key element in many clean energy technologies. The name cobalt comes from the German word kobold, meaning goblin. It was given this name by medieval miners who believed that troublesome goblins replaced the valuable metals in their ore with a substance that emitted poisonous fumes when smelted. The Swedish chemist Georg Brandt isolated metallic cobalt-the first new metal to be discovered since ancient times-in about 1735 and identified some of its valuable properties.

  8. Cobalt release from implants and consumer items and characteristics of cobalt sensitized patients with dermatitis

    DEFF Research Database (Denmark)

    Thyssen, Jacob Pontoppidan; Menne, Torkil; Liden, Carola

    2012-01-01

    -containing dental alloys and revised hip implant components.Results. Six of eight dental alloys and 10 of 98 revised hip implant components released cobalt in the cobalt spot test, whereas none of 50 mobile phones gave positive reactions. The clinical relevance of positive cobalt test reactions was difficult......-tested dermatitis patients in an attempt to better understand cobalt allergy.Materials and methods. 19 780 dermatitis patients aged 4-99 years were patch tested with nickel, chromium or cobalt between 1985 and 2010. The cobalt spot test was used to test for cobalt ion release from mobile phones as well as cobalt...

  9. Electroplated zinc-cobalt alloy

    International Nuclear Information System (INIS)

    Carpenter, D.E.O.S.; Farr, J.P.G.

    2005-01-01

    Recent work on the deposition and use of ectrodeposited zinc-cobalt alloys is surveyed. Alloys containing lower of Nuclear quantities of cobalt are potentially more useful. The structures of the deposits is related to their chemical and mechanical properties. The inclusion of oxide and its role in the deposition mechanism may be significant. Chemical and engineering properties relate to the metallurgical structure of the alloys, which derives from the mechanism of deposition. The inclusion of oxides and hydroxides in the electroplate may provide evidence for this mechanism. Electrochemical impedance measurements have been made at significant deposition potentials, in alkaline electrolytes. These reveal a complex electrode behaviour which depends not only on the electrode potential but on the Co content of the electrolyte. For the relevant range of cathodic potential zinc-cobalt alloy electrodeposition occurs through a stratified interface. The formation of an absorbed layer ZnOH/sup +/ is the initial step, this inhibits the deposition of cobalt at low cathodic potentials, so explaining its 'anomalous deposition'. A porous layer of zinc forms on the adsorbed ZnOH/sup +/ at underpotential. As the potential becomes more cathodic, cobalt co- deposits from its electrolytic complex forming a metallic solid solution of Co in Zn. In electrolytes containing a high concentration of cobalt a mixed entity (ZnCo)/sub +/ is assumed to adsorb at the cathode from which a CoZn intermetallic deposits. (author)

  10. COBALT SALTS PRODUCTION BY USING SOLVENT EXTRACTION

    Directory of Open Access Journals (Sweden)

    Liudmila V. Dyakova

    2010-06-01

    Full Text Available The paper deals with the extracting cobalt salts by using mixtures on the basis of tertiary amine from multicomponent solutions from the process of hydrochloride leaching of cobalt concentrate. The optimal composition for the extraction mixture, the relationship between the cobalt distribution coefficients and modifier’s nature and concentration, and the saltingout agent type have been determined. A hydrochloride extraction technology of cobalt concentrate yielding a purified concentrated cobalt solution for the production of pure cobalt salts has been developed and introduced at Severonikel combine.

  11. Reload of cobalt 60 for the J S-6500 irradiator

    International Nuclear Information System (INIS)

    Torres C, G.; Mayoral G, V.M.

    1991-01-01

    The present work has the purpose to describe the activities of the reloads program of the industrial irradiator J S-6500, elaborated for satisfying part of the demand of services and as a first step, to guide the decision making by the part of the ININ authorities in front of a wide market of this service. (Author)

  12. Dosemeter calibration in X-ray and in cobalt-60

    International Nuclear Information System (INIS)

    Silva, T.A. da

    1988-01-01

    Some tests about quality security for clinical dosemeter calibration in secondary standard dosimetry laboratory are described. The tests in gama calibration system, in X-ray calibration, in secondary standard dosimeter, in the dosemeter that will be calibrated, during the calibration and after the calibration are shown. (C.G.C.) [pt

  13. Overdevelopment tests in steel gammagraphy with cobalt 60 radiation

    International Nuclear Information System (INIS)

    Cinotti, C.; Cocoual, N.

    1985-01-01

    In the case of radiographic control of important thickness of steels, rapidity and image quality characteristics of overdeveloped radiographic films have been studied. Conditions have been fixed allowing to get a sensitive reduction of exposition times without modifying the radiogram quality [fr

  14. Phosphorus introduction mechanism in electrodeposited cobalt films

    International Nuclear Information System (INIS)

    Kravtchenko, Jean-Francois

    1973-01-01

    The cathodic reduction of hypophosphite, phosphite and phosphate ions was studied using chrono-potentiometry and voltammetry. Then cobalt was deposited at constant current from a bath containing one of these three compounds. The current, while giving an electrodeposition of cobalt, also enhances at the same time a chemical deposition of cobalt. It is shown that high coercive forces in cobalt films are much more related to this chemical deposition than to the simple fact that the films contain some phosphorus. (author) [fr

  15. Radioactive and stable cobalt concentrations in mussel in Kyushu island, Japan

    International Nuclear Information System (INIS)

    Momoshima, Noriyuki; Shiki, Atsushi; Takashima, Yoshimasa; Maki, Takao; Koriyama, Munehiro; Shimozono, Seika; Imamura, Hiroka; Nakamata, Kojiro.

    1985-01-01

    Two kinds of mussel, Septifer virgatus and Mytilus edulis, were collected from Kyushu island, Japan, in order to elucidate a background level of 60 Co, which is one of the most significant radionuclide for environmental monitoring around a nuclear power plant. The mussels were collected from 7 locations in 1983 and classified 2 or 3 groups depending on their shell size at each location. Activities of 60 Co were measured by a low-background β counter after purified by means of chemical separation and electrodeposition. Stable cobalt concentrations were determined by colorimetric method. The concentrations of cobalt in Septifer virgatus are one order higher level than that in Mytilus edulis. There are not so large difference in cobalt content depending on shell size so long as comparing them at the same location. The radioactivities in mussels show the same trend as stable cobalt. It has become apparent that Septifer virgatus has a tendency to concentrate cobalt with growing but Mytilus edulis is opposite. The cobalt-60 introduced to sea from nuclear explosions seems to be relatively constant in coastal seawater since specific activities are distributed in a narrow range in spite of kind, shell size and location. (author)

  16. Health physics monitoring during cobalt slug rod handling at research reactor Dhruva: an experience

    International Nuclear Information System (INIS)

    Verma, Gopal P.; Bhatnagar, Amit; Krishnamohanan, T.; Kalyanasundaram, N.; Gupta, P.C.; Pushparaja; Ghosh, Runner

    2006-01-01

    Cobalt-60 is used in many industrial and medical applications, such as leveling devices, thickness gauge, sterilization of foodstuff to increase their shelf life, sterilization of medicines and in radiotherapy. The Cobalt slug rod containing cobalt pencils were irradiated for nearly two and half years in the Dhruva reactor core to obtain the 60 Co isotope. It had seen a total irradiation of 29053 MWD and the estimated total activity was 93.321 KCi. Campaign for the removal of irradiated rod from reactor core and retrieval of 60 Co pencils were carried out successfully in Dhruva Reactor complex. In view of such a high activity handled, the job was carried out after exhaustive prior planning and according to approved checklists. Radiation Hazards Control Unit, Dhruva provided Radiation Safety surveillance during the entire handling operation consisting of retrieval of the cobalt pencils and disposal of the aluminum slugs used to house the cobalt pencils in the Cobalt slug rod assembly. The whole operation was carried out in such a safe manner that the total man-rem consumption was insignificant. The operational radiation protection methods followed and the experience gained during the campaign are discussed in this paper. (author)

  17. Molecular mechanics calculations on cobalt phthalocyanine dimers

    NARCIS (Netherlands)

    Heuts, J.P.A.; Schipper, E.T.W.M.; Piet, P.; German, A.L.

    1995-01-01

    In order to obtain insight into the structure of cobalt phthalocyanine dimers, molecular mechanics calculations were performed on dimeric cobalt phthalocyanine species. Molecular mechanics calculations are first presented on monomeric cobalt(II) phthalocyanine. Using the Tripos force field for the

  18. Cobalt oxide nanoparticle-modified carbon nanotubes as an ...

    Indian Academy of Sciences (India)

    of 60 mV were observed at. 100 mV s. −1 for CoOx−MWNT/GCE. An anodic peak at. 100 mV attributed to Co(II)/Co(III) redox transition associated with the electrode surface. The cathodic peak at 20 mV corre- spond to the reduction of various cobalt oxide species formed during the anodic sweep. The stability of the modified ...

  19. Cobalt(II) and Cobalt(III) Coordination Compounds.

    Science.gov (United States)

    Thomas, Nicholas C.; And Others

    1989-01-01

    Presents a laboratory experiment which illustrates the formation of tris(phenanthroline)cobalt complexes in the 2+ and 3+ oxidation states, the effect of coordination on reactions of the ligand, and the use of a ligand displacement reaction in recovering the transformed ligand. Uses IR, UV-VIS, conductivity, and NMR. (MVL)

  20. Impurity diffusion of cobalt in plutonium

    International Nuclear Information System (INIS)

    Charissoux, Christian; Calais, Daniel.

    1975-01-01

    The sectioning method for investigation of the impurity diffusion of 60 Co in the fcc and bcc phases of plutonium gives the following results: 344-426 deg C: D=1.2x10 -2 exp(-12700/RT)cm 2 /s in delta Pu(fcc); 484-621 deg C: D=1.4x10 -3 exp(-9900/RT)cm 2 /s in epsilon Pu(bcc). Cobalt is a fast diffuser in plutonium; the diffusion coefficient being unaffected by phase changes delta'→delta; delta'→epsilon, the diffusion mechanism is probably dissociative in both phases, the solute becoming interstitial by: solute (substitution) reversible solute (interstitial) + vacancy [fr

  1. Sorption of 60 Co in natural zeolite (clinoptilolite)

    International Nuclear Information System (INIS)

    Hernandez B, E.

    1996-01-01

    A Mexican zeolite (clinoptilolite) from Taxco, Guerrero, was partially stabilized with sodium cations. Radioactive Cobalt ( 60 Co) was used to study the Co 2+ sorption in the stabilized zeolite (Na + ). It was found that sorption in general does not favour the diffusion of cobalt between framework, it explains because of it is a natural zeolite and its composition heterogeneous decrease its exchange capacity by the generated competence to the existence other type of exchange ions. The cobalt retention reached the highest level, around 0.408 m eq Co 2+ /g in the Na-Clinoptilolite. The crystallinity of the aluminosilicates was maintained during experiments, it was verified by XRD patterns. (Author)

  2. Sorption of 60Co on a synthetic titanosilicate analogue of the mineral penkvilksite-2O and antimonysilicate

    International Nuclear Information System (INIS)

    Koudsi, Y.; Dyer, A.

    2001-01-01

    The ability of two different types of synthetic inorganic ion-exchangers to sorb radioactive cobalt-60 using a batch-type method was studied. The two materials examined were the analogue of the natural titanosilicate penkvilksite-2O (AM-3) and a synthetic antimonysilicate. Ion-exchange experiments were performed with solutions labelled with radioactive cobalt ( 60 Co). The sorption of 60 Co onto the two samples materials were compared in terms of distribution coefficient (K d ), sorption percentage and cobalt quantity removed in mg per gram weight of the material. Several parameters were investigated viz. contact time, cobalt concentration, and sorbent concentration. It was found that the batch factor and cobalt concentration had a significant influence on the sorption of cobalt onto both of the materials. This was associated with the difference in pH generated by suspensions of the materials in water which was alkaline for the penkvilksite-2O analogue, and acid for the synthetic antimonysilicate. (author)

  3. Cobalt release from inexpensive jewellery: has the use of cobalt replaced nickel following regulatory intervention?

    Science.gov (United States)

    Thyssen, Jacob Pontoppidan; Jellesen, Morten S; Menné, Torkil; Lidén, Carola; Julander, Anneli; Møller, Per; Johansen, Jeanne Duus

    2010-08-01

    Before the introduction of the EU Nickel Directive, concern was raised that manufacturers of jewellery might turn from the use of nickel to cobalt following the regulatory intervention on nickel exposure. The aim was to study 354 consumer items using the cobalt spot test. Cobalt release was assessed to obtain a risk estimate of cobalt allergy and dermatitis in consumers who would wear the jewellery. The cobalt spot test was used to assess cobalt release from all items. Microstructural characterization was made using scanning electron microscope (SEM) and energy-dispersive spectroscopy (EDS). Cobalt release was found in 4 (1.1%) of 354 items. All these had a dark appearance. SEM/EDS was performed on the four dark appearing items which showed tin-cobalt plating on these. This study showed that only a minority of inexpensive jewellery purchased in Denmark released cobalt when analysed with the cobalt spot test. As fashion trends fluctuate and we found cobalt release from dark appearing jewellery, cobalt release from consumer items should be monitored in the future. Industries may not be fully aware of the potential cobalt allergy problem.

  4. Self-powered in-core detectors of cobalt type

    International Nuclear Information System (INIS)

    Jonsson, Georg

    1975-01-01

    Testing and development of self-powered neutron detectors with a cobalt emitter is described. Long term irradiation at 400 deg C is expected to indicate insulation quality, change in calibration and 60 Co build-up. Dynamic tests to investigate possible transient effects due to temperature changes are being performed on a number of detectors up to about 600 deg C. A long term irradiation at low temperature has been terminated after 4.5 years. On completion, neutron dose was estimated to be 5.6 x 10 21 nvt and the 60 Co background was 9.3 % of the full flux signal. A recently introduced long term test is expected to provide data on instability effects due to 61 Co. For a BWR in-core detector installation, the main advantage of cobalt detectors, apart from the small size, appears to be long life. Development work is being done on detectors with vanadium-cobalt emitters, electronic separation of fast and delayed signals and reduction of gamma sensitivity. (O.T.)

  5. Study of recombination processes for 'electron-hole' pairs in germanium irradiated by {gamma} rays from {sup 60}Co using the photovoltaic effect in P-N junctions; Etude du processus de recombinaison des paires ''electron-trou'' dans le germanium irradie par les rayons {gamma} du cobalt 60 a l'aide de l'effet photovoltaique dans les jonctions P-N

    Energy Technology Data Exchange (ETDEWEB)

    Zahedi-Mochadam, A A [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1964-10-01

    Using the photo-voltaic effect in p-n junctions, we have studied, during bombardment, the mechanism of the recombination of 'electron-hole' pairs in the presence of structure defects produced in germanium of the N and P types by {gamma} rays from a Co{sup 60} source. At 310 K the level of the recombination centres is situated 0.25 eV above the conduction band and the capture cross-sections of the holes and of the electrons have the respective values of: {sigma}{sub p} = 4 X 10{sup -15} cm{sup 2} and {sigma}{sub n} = 3 X 10{sup -15} cm{sup 2}. The value of {sigma}{sub n} appears to be under-estimated because the number of defects in P-type samples appears to be lower than that in N-type samples. These results lead to the conclusion that the interstitials are responsible for the recombination. At 80 K it has been found that in N-type samples, a shallow level exists at O.05 eV below the conduction band with a capture cross-section for the holes of {sigma}{sub p} {>=} 10{sup -14} cm{sup 2}. We believe that in this case the recombination of charge carriers is controlled by the neighbouring 'defect-interstitial' pairs. In P-type samples at low temperature, the life-time is practically constant during irradiation. This fact is attributed to a spontaneous annealing of defects ol purely electrical origin. In the last part of the work the study of the photo-voltaic effect applied to the problem of gamma radiation dosimetry is considered. It is shown that such dosimeters, based on this principle, make it possible to measure the intensity of gamma rays over a very wide range. (author) [French] En utilisant l'effet photovoltaique dans les jonctions p-n, nous avons etudie au cours du bombardement le mecanisme de recombinaison des paires 'electron-trou' en presence des defauts de structure introduits dans le germanium de type N et de type P par les rayons gamma d'une source de Co{sup 60}. A 310 K, le niveau des centres de recombinaison se trouve a 0,25 eV au-dessous de la bande

  6. Polytypic transformations during the thermal decomposition of cobalt hydroxide and cobalt hydroxynitrate

    International Nuclear Information System (INIS)

    Ramesh, Thimmasandra Narayan

    2010-01-01

    The isothermal decomposition of cobalt hydroxide and cobalt hydroxynitrate at different intervals of temperature leads to the formation of Co 3 O 4 . The phase evolution during the decomposition process was monitored using powder X-ray diffraction. The transformation of cobalt hydroxide to cobalt oxide occurs via three phase mixture while cobalt hydroxynitrate to cobalt oxide occurs through a two phase mixture. The nature of the sample and its preparation method controls the decomposition mechanism. The comparison of topotactical relationship between the precursors to the decomposed product has been reported in relation to polytypism. - Graphical abstract: Isothermal thermal decomposition studies of cobalt hydroxide and cobalt hydroxynitrate at different intervals of temperature show the metastable phase formed prior to Co 3 O 4 phase.

  7. Programme of hot points eradication (Co-60) led on French PWR type reactors

    International Nuclear Information System (INIS)

    Rocher, A.; Ridoux, P.; Anthoni, S.; Brun, C.

    1998-01-01

    The question of hot points (pellets rich in cobalt 59 or in cobalt 60 in a PWR type reactor), is studied from the radiation protection point of view. The purpose is to see how to optimize the radiation protection, the elimination of these hot points can bring an improvement. (N.C.)

  8. Recovery of Cobalt as Cobalt Oxalate from Cobalt Tailings Using Moderately Thermophilic Bioleaching Technology and Selective Sequential Extraction

    Directory of Open Access Journals (Sweden)

    Guobao Chen

    2016-07-01

    Full Text Available Cobalt is a very important metal which is widely applied in various critical areas, however, it is difficult to recover cobalt from minerals since there is a lack of independent cobalt deposits in nature. This work is to provide a complete process to recover cobalt from cobalt tailings using the moderately thermophilic bioleaching technology and selective sequential extraction. It is found that 96.51% Co and 26.32% Cu were extracted after bioleaching for four days at 10% pulp density. The mean compositions of the leach solutions contain 0.98 g·L−1 of Co, 6.52 g·L−1 of Cu, and 24.57 g·L−1 of Fe (III. The copper ion was then recovered by a solvent extraction process and the ferric ions were selectively removed by applying a goethite deironization process. The technological conditions of the above purification procedures were deliberately discussed. Over 98.6% of copper and 99.9% of ferric ions were eliminated from the leaching liquor. Cobalt was finally produced as cobalt oxalate and its overall recovery during the whole process was greater than 95%. The present bioleaching process of cobalt is worth using for reference to deal with low-grade cobalt ores.

  9. Ionizing radiation effects of Cobalt-60 on the physical-chemical, sensorial and microbiological of bread with addition of linseed (Linum usitatissimum); Efeitos da radiacao ionizante de cobalto-60 nas caracteristicas fisico-quimicas sensoriais e microbiolgicas de paes com adicao de linhaca (Linum usitatissimum)

    Energy Technology Data Exchange (ETDEWEB)

    Moura, Neila Camargo de

    2011-07-01

    The incorporation of functional ingredients on breading products has grown very much lately, because of the preoccupation with the consumers' health. The linseed has awakened the interest by its high level of fiber, lignin, omega-3 and antioxidants compounds. The objective of the present work is evaluate the ionizing radiation effect of {sup 60}Co on the physical-chemical, sensorial and microbiological characteristics of bread with addition of different concentration of brown linseed. There were elaborated 3 types of bread: French roll, form bread prepared with the mixture and form bread produced with conventional ingredients. It was added smashed brown linseed on the bread dough, with concentrations of 8% and 12%. After the preparation, the three kinds of bread packed with polypropylene packages and taken to the IPEN/USP (Institute of Nuclear Energetic Research/University of São Paulo) and irradiated with doses of 6, 8 and 10 kGy. Treatments were elaborated without the addition of linseed and without irradiation, for control, totalizing 12 distinct treatments, to each bread formula tested. Chemical analyses were made (centesimal composition, anti-nutritional compounds, anti-oxidant activity, glycemic index, fat acids, complex B vitamins and minerals); physical analyses (cooking index, volume, color and water activity); sensorial analyses (preference tests and Descriptive Quantitative Analysis - ADQ); microbiological analysis and a survey about irradiated products. It could be seen that the addition of linseed was efficient to increase the level of alimentary fiber and the level of lipids on the 3 bread formula. The three kinds of bread that received the linseed addition and that were not irradiated presented increase on the level of total phenolic; however, when the samples which received the linseed addition were submitted to the irradiation process, it could be noticed the decrease of the antioxidant capacity. There was an increase on the level of omega-3

  10. Derivative spectrophotometry of cobalt alloys

    International Nuclear Information System (INIS)

    Spitsyn, P.K.

    1985-01-01

    The method of derivative spectrophotometry is briefly described, and derivative absorption spectra are presented for samarium, cobalt, and commercial Sm-Co alloys. It is shown that the use of derivative spectrophotometry not only improves the accuracy and selectivity of element determinations but also simplifies the analysis of alloys. Results of a statistical evaluation of the metrological characteristics of the analytical procedure described here are presented. 8 references

  11. Thermal effect on structure organizations in cobalt-fullerene nanocomposition.

    Science.gov (United States)

    Lavrentiev, Vasily; Vacik, Jiri; Naramoto, Hiroshi; Sakai, Seiji

    2010-04-01

    Effect of deposition temperature (Ts) on structure of Co-C60 nanocomposite (NC) prepared by simultaneous deposition of cobalt and fullerene on sapphire is presented. The NC structure variations with Ts increasing from room temperature (RT) to 400 degrees C have been analyzed using scanning electron microscopy (SEM), atomic force microscopy (AFM) and Raman spectroscopy. AFM and SEM show granule-like structure of the Co-C60 film. The mixture film deposited at RT includes the hills on the surface suggesting accumulation of internal stress during phase separation. Raman spectra show 25 cm(-1) downshift of Ag(2) C60 peak suggesting -Co-C60- polymerization in C60-based matrix of the NC film. Analysis of Raman spectra has revealed existence of amorphous carbon (a-C) in the NC matrix that argues C60 decomposition. The Ts increase to 200 degrees C causes the surface hills smoothing. In parallel, downshift of the Ag(2) peak decreases to 16 cm(-1) that implies more pronounced phase separation and lower -Co-C60- polymerization efficiency. Also, amount of a-C content slightly increases. Further Ts increasing to 400 degrees C changes the NC structure dramatically. AFM shows evident enlargement of the granules. According to Raman spectra the high Ts deposition yields pronounced C60 decomposition increasing the a-C content. Features of a-C Raman peak imply nucleation of graphitic islands at the NC interfaces. Abundant decomposition of C60 in the mixture film deposited at 400 degrees C is referred to cobalt catalytic effect.

  12. Process and system to control manganese and cobalt isotopes deposits from the cooling fluid of a reactor

    International Nuclear Information System (INIS)

    Brehm, W.F.; McGuire, J.C.

    1978-01-01

    Process for controlling the deposition of manganese-54, cobalt-58 and cobalt-60 radionuclides on component surfaces, as from a liquid flow containing these nuclides and entering into contact with the surface of these components. It is characterised by the positioning of a getter forming substance in the liquid flow to collect these radionuclides on the getter forming substance which contains at least 73% nickel by weight [fr

  13. Cobalt allergy in hard metal workers

    Energy Technology Data Exchange (ETDEWEB)

    Fischer, T; Rystedt, I

    1983-03-01

    Hard metal contains about 10% cobalt. 853 hard metal workers were examined and patch tested with substances from their environment. Initial patch tests with 1% cobalt chloride showed 62 positive reactions. By means of secondary serial dilution tests, allergic reactions to cobalt were reproduced in 9 men and 30 women. Weak reactions could not normally be reproduced. A history of hand eczema was found in 36 of the 39 individuals with reproducible positive test reactions to cobalt, while 21 of 23 with a positive initial patch test but negative serial dilution test had never had any skin problems. Hand etching and hand grinding, mainly female activities and traumatic to the hands, were found to involve the greatest risk of cobalt sensitization. 24 individuals had an isolated cobalt allergy. They had probably been sensitized by hard metal work, while the individuals, all women, who had simultaneous nickel allergy had probably been sensitized to nickel before their employment and then became sensitized to cobalt by hard metal work. A traumatic occupation, which causes irritant contact dermatitis and/or a previous contact allergy or atopy is probably a prerequisite for the development of cobalt allergy.

  14. CARDIOPROTECTIVE EFFECT OF NATIVE ANTIHYPOXANTS IN EXPERIMENTAL COBALT CARDIOMYOPATHY

    Directory of Open Access Journals (Sweden)

    I. V. Zadnipryany

    2016-01-01

    Full Text Available The aim of research – the study of cardioprotective properties of antioxidants in terms of histotoxic hypoxia under experimental conditions.Materials and methods. The study was conducted on 20 adult male Wistar rats divided into 3 experimental groups, which for 7 days were intraperitoneally injected aqueous CoCl2 solution at a dose of 60 mg/kg. Rats of the first experimental group (n = 6 had no administered drug correction, a the second group of animals (n = 7 after the cobalt chloride daily injections was administered intragastrically Enoant Premium aqueous solution at a dose of 2.5 ml / kg, along with 0.05 ml of water, the rats the third test group (n = 7 after the administration of cobalt chloride were exposed to cytoflavin correction concentrate and grape polyphenols administered simultaneously. Studies of myocardium were conducted using light and electron microscopy.Results of the research. The result of the cobalt toxic effect on the heart of animals in experiments lead to the development of cardiomyopathy, which required timely cardioprotection. Morphological changes in the second group of rats, despite a slight improvement compared with the group without correction,were characterized, above all, by uneven from mild to severe edema of the myocardium. Structure of myocardium observed in the third group of male rats after cobalt intoxication, generally reflected a tendency to minimization of the extent of the damage, which was manifested in the form of normalization of cell structures and muscle fibers.Conclusion. The administration of succinic acid derivatives combined with the grape polyphenols demonstrated vivid cytoprotective properties evidenced by mostly preserved myocardium structure in rats exposed to histotoxic hypoxia in comparison to only administration of plant polyphenols group. 

  15. Physical aspects of quality assurance in cobalt teletherapy units

    Energy Technology Data Exchange (ETDEWEB)

    Ng, Kwan Hong [Malaya Univ., Kuala Lumpur (Malaysia)

    1989-06-01

    ICRU Report No. 24 states that +- 5% is a reasonable degree of accuracy to strive for in the delivery of absorbed doses to target volumes in radiotherapy. To achieve this quality assurance level, a comprehensive programme comprising both physical and clinical components is needed. The purpose of this paper is to present the rationale and guidelines for implementing a recommended quality assurance programme. It will emphasize the physical aspects pertaining to acceptance and constancy tests using Cobalt-60 teletherapy units. It will also outline a suggested schedule of quality assurance testings including radiation dosimetry, geometry and electrochemical safety. (author).

  16. Synthesis, analysis and radiolysis of the cobalt III 8 hydroxyquinolinate complex

    International Nuclear Information System (INIS)

    Mestnik, S.A.C.; Silva, C.P.G. da.

    1981-11-01

    The cobalt III 8-hidroxyquinolinate complex was syntetized from a solution of cobalt II. The compound was analysed by IR absorption spectroscopy, elemental analysis and by the determination of number of ligands. The radiolytic degradation was verified by spectrophotometry after submitting samples of 10 - 3 M complex in ethanolic solution to different doses of gamma radiation from a 60 Co source. The change of maximum absorbance of the complex with different doses of gamma radiation and its UV-VIS absorption spectra are presented. The complex in the solid state was also irradiated with 6,9 Mrad of gamma radiation but it didn't present degradation. (Author) [pt

  17. Nickel acts as an adjuvant during cobalt sensitization

    DEFF Research Database (Denmark)

    Bonefeld, Charlotte Menne; Nielsen, Morten Milek; Vennegaard, Marie T.

    2015-01-01

    Metal allergy is the most frequent form of contact allergy with nickel and cobalt being the main culprits. Typically, exposure comes from metal-alloys where nickel and cobalt co-exist. Importantly, very little is known about how co-exposure to nickel and cobalt affects the immune system. We...... investigated these effects by using a recently developed mouse model. Mice were epicutaneously sensitized with i) nickel alone, ii) nickel in the presence of cobalt, iii) cobalt alone, or iv) cobalt in the presence of nickel, and then followed by challenge with either nickel or cobalt alone. We found...... that sensitization with nickel alone induced more local inflammation than cobalt alone as measured by increased ear-swelling. Furthermore, the presence of nickel during sensitization to cobalt led to a stronger challenge response to cobalt as seen by increased ear-swelling and increased B and T cell responses...

  18. Recovery of cobalt from spent lithium-ion batteries using supercritical carbon dioxide extraction.

    Science.gov (United States)

    Bertuol, Daniel A; Machado, Caroline M; Silva, Mariana L; Calgaro, Camila O; Dotto, Guilherme L; Tanabe, Eduardo H

    2016-05-01

    Continuing technological development decreases the useful lifetime of electronic equipment, resulting in the generation of waste and the need for new and more efficient recycling processes. The objective of this work is to study the effectiveness of supercritical fluids for the leaching of cobalt contained in lithium-ion batteries (LIBs). For comparative purposes, leaching tests are performed with supercritical CO2 and co-solvents, as well as under conventional conditions. In both cases, sulfuric acid and H2O2 are used as reagents. The solution obtained from the supercritical leaching is processed using electrowinning in order to recover the cobalt. The results show that at atmospheric pressure, cobalt leaching is favored by increasing the amount of H2O2 (from 0 to 8% v/v). The use of supercritical conditions enable extraction of more than 95wt% of the cobalt, with reduction of the reaction time from 60min (the time employed in leaching at atmospheric pressure) to 5min, and a reduction in the concentration of H2O2 required from 8 to 4% (v/v). Electrowinning using a leach solution achieve a current efficiency of 96% and a deposit with cobalt concentration of 99.5wt%. Copyright © 2016 Elsevier Ltd. All rights reserved.

  19. Nickel and cobalt base alloys

    International Nuclear Information System (INIS)

    Houlle, P.

    1994-01-01

    Nickel base alloys have a good resistance to pitting, cavernous or cracks corrosion. Nevertheless, all the nickel base alloys are not equivalent. Some differences exit between all the families (Ni, Ni-Cu, Ni-Cr-Fe, Ni-Cr-Fe-Mo/W-Cu, Ni-Cr-Mo/W, Ni-Mo). Cobalt base alloys in corrosive conditions are generally used for its wear and cracks resistance, with a compromise to its localised corrosion resistance properties. The choice must be done from the perfect knowledge of the corrosive medium and of the alloys characteristics (chemical, metallurgical). A synthesis of the corrosion resistance in three medium (6% FeCl 3 , 4% NaCl + 1% HCl + 0.1% Fe 2 (SO 4 ) 3 , 11.5% H 2 SO 4 + 1.2% HCl + 1% Fe 2 (SO 4 ) 3 + 1% CuCl 2 ) is presented. (A.B.). 11 refs., 1 fig., 12 tabs

  20. Preparation of high purity cobalt

    International Nuclear Information System (INIS)

    Isshiki, M.; Fukuda, Y.; Igaki, K.

    1985-01-01

    A combination of anion exchange separation, electrolytic extraction, floating zone refining and dry hydrogen treatment was used to purify cobalt. The effectiveness of each purification process was confirmed by measurements of the residual resistivity ratio (RRR) and activation analyses. Proton activation analysis revealed that all the main metallic impurities except iron were effectively removed by a combination of these processes. The effective removal of oxygen, nitrogen and carbon by dry hydrogen treatment was confirmed by activation analyses using 3 He ion beams, proton beams and γ rays. It was found that the rate-controlling step in the decarburization process was a surface reaction. The maximum RRR obtained for the purified specimen was 334, which is higher than previously reported values. (Auth.)

  1. Kruger 60

    Science.gov (United States)

    Knapp, Wilfried; Nanson, John

    2018-01-01

    As announced in our report “Measurements of WDS Objects found in images taken for detecting CPM pairs in the LSPM catalog” we present here a report on Kruger 60. This multiple is listed in WDS with such a large number of components that we thought it deserves a separate report.

  2. Bioremediation of {sup 60}Co from simulated spent decontamination solutions

    Energy Technology Data Exchange (ETDEWEB)

    Rashmi, K.; Naga Sowjanya, T.; Maruthi Mohan, P.; Balaji, V.; Venkateswaran, G

    2004-07-26

    Bioremediation of {sup 60}Co from simulated spent decontamination solutions by utilizing different biomass of (Neurospora crassa, Trichoderma viridae, Mucor recemosus, Rhizopus chinensis, Penicillium citrinum, Aspergillus niger and, Aspergillus flavus) fungi is reported. Various fungal species were screened to evaluate their potential for removing cobalt from very low concentrations (0.03-0.16 {mu}M) in presence of a high background of iron (9.33 mM) and nickel (0.93 mM) complexed with EDTA (10.3 mM). The different fungal isolates employed in this study showed a pickup of cobalt in the range 8-500 ng/g of dry biomass. The [Fe]/[Co] and [Ni]/[Co] ratios in the solutions before and after exposure to the fungi were also determined. At micromolar level the cobalt pickup by many fungi especially the mutants of N. crassa is seen to be proportional to the initial cobalt concentration taken in the solution. However, R. chinensis exhibits a low but iron concentration dependent cobalt pickup. Prior saturating the fungi with excess of iron during their growth showed the presence of selective cobalt pickup sites. The existence of cobalt specific sorption sites is shown by a model experiment with R. chinensis wherein at a constant cobalt concentration (0.034 {mu}M) and varying iron concentrations so as to yield [Fe/Co]{sub initial} ratios in solution of 10, 100, 1000 and 287 000 have all yielded a definite Co pickup capacity in the range 8-47 ng/g. The presence of Cr(III)EDTA (3 mM) in solution along with complexed Fe and Ni has not influenced the cobalt removal. The significant feature of this study is that even when cobalt is present in trace level (sub-micromolar) in a matrix of high concentration (millimolar levels) of iron, nickel and chromium, a situation typically encountered in spent decontamination solutions arising from stainless steel based primary systems of nuclear reactors, a number of fungi studied in this work showed a good sensitivity for cobalt pickup.

  3. Bioremediation of 60Co from simulated spent decontamination solutions

    International Nuclear Information System (INIS)

    Rashmi, K.; Naga Sowjanya, T.; Maruthi Mohan, P.; Balaji, V.; Venkateswaran, G.

    2004-01-01

    Bioremediation of 60 Co from simulated spent decontamination solutions by utilizing different biomass of (Neurospora crassa, Trichoderma viridae, Mucor recemosus, Rhizopus chinensis, Penicillium citrinum, Aspergillus niger and, Aspergillus flavus) fungi is reported. Various fungal species were screened to evaluate their potential for removing cobalt from very low concentrations (0.03-0.16 μM) in presence of a high background of iron (9.33 mM) and nickel (0.93 mM) complexed with EDTA (10.3 mM). The different fungal isolates employed in this study showed a pickup of cobalt in the range 8-500 ng/g of dry biomass. The [Fe]/[Co] and [Ni]/[Co] ratios in the solutions before and after exposure to the fungi were also determined. At micromolar level the cobalt pickup by many fungi especially the mutants of N. crassa is seen to be proportional to the initial cobalt concentration taken in the solution. However, R. chinensis exhibits a low but iron concentration dependent cobalt pickup. Prior saturating the fungi with excess of iron during their growth showed the presence of selective cobalt pickup sites. The existence of cobalt specific sorption sites is shown by a model experiment with R. chinensis wherein at a constant cobalt concentration (0.034 μM) and varying iron concentrations so as to yield [Fe/Co] initial ratios in solution of 10, 100, 1000 and 287 000 have all yielded a definite Co pickup capacity in the range 8-47 ng/g. The presence of Cr(III)EDTA (3 mM) in solution along with complexed Fe and Ni has not influenced the cobalt removal. The significant feature of this study is that even when cobalt is present in trace level (sub-micromolar) in a matrix of high concentration (millimolar levels) of iron, nickel and chromium, a situation typically encountered in spent decontamination solutions arising from stainless steel based primary systems of nuclear reactors, a number of fungi studied in this work showed a good sensitivity for cobalt pickup

  4. Nano cobalt oxides for photocatalytic hydrogen production

    KAUST Repository

    Mangrulkar, Priti A.; Joshi, Meenal M.; Tijare, Saumitra N.; Polshettiwar, Vivek; Labhsetwar, Nitin K.; Rayalu, Sadhana Suresh

    2012-01-01

    of various operating parameters in hydrogen generation by nano cobalt oxide was then studied in detail. Copyright © 2012, Hydrogen Energy Publications, LLC. Published by Elsevier Ltd. All rights reserved.

  5. Transport properties of cobalt at low temperatures

    DEFF Research Database (Denmark)

    Radharkishna, P.; Nielsen, Mourits

    1965-01-01

    Measurements are made of electrical resistivity, absolute thermoelectric power, and thermal conductivity of polycrystalline cobalt between 1.2 and 6 K; results are discussed on basis of inter-electronic scattering.......Measurements are made of electrical resistivity, absolute thermoelectric power, and thermal conductivity of polycrystalline cobalt between 1.2 and 6 K; results are discussed on basis of inter-electronic scattering....

  6. COBALT COMPOUNDS AS ANTIDOTES FOR HYDROCYANIC ACID.

    Science.gov (United States)

    EVANS, C L

    1964-12-01

    The antidotal potency of a cobalt salt (acetate), of dicobalt edetate, of hydroxocobalamin and of cobinamide against hydrocyanic acid was examined mainly on mice and rabbits. All the compounds were active antidotes for up to twice the LD50; under some conditions for larger doses. The most successful was cobalt acetate for rabbits (5xLD50), which was effective at a molar cyanide/cobalt (CN/Co) ratio of 5, but had as a side-effect intense purgation. Hydroxocobalamin was irregular in action, but on the whole was most effective for mice (4.5xLD50 at a molar ratio of 1), and had no apparent side effects. Dicobalt edetate, at molar ratios of up to 2, was more effective for rabbits (3xLD50) than for mice (2xLD50), but had fewer side effects than cobalt acetate. The effect of thiosulphate was to augment the efficacy of dicobalt edetate and, in mice, that of hydroxocobalamin; but, apparently, in rabbits, to reduce that of hydroxocobalamin. Cobinamide, at a molar ratio of 1, was slightly more effective than hydroxocobalamin on rabbits and also less irregular in its action. Cobalt acetate by mouth was effective against orally administered hydrocyanic acid. The oxygen uptake of the body, reduced by cyanide, is rapidly reinstated when one of the cobalt antidotes has been successfully administered.

  7. Distribution measurement of 60Co target radioactive specific activity

    International Nuclear Information System (INIS)

    Li Xingyan; Chen Zigen; Ren Min

    1994-01-01

    Radioactive specific activity distribution of cobalt 60 target by irradiation in HFETR is a key parameter. With the collimate principle, the under water measurement device and conversion coefficient which is get by experiments, and the radioactive specific activity distribution is obtained. The uncertainty of measurement is less than 10%

  8. Cobalt release from inexpensive jewellery: has the use of cobalt replaced nickel following regulatory intervention?

    DEFF Research Database (Denmark)

    Thyssen, Jacob Pontoppidan; Jellesen, Morten S; Menné, Torkil

    2010-01-01

    Before the introduction of the EU Nickel Directive, concern was raised that manufacturers of jewellery might turn from the use of nickel to cobalt following the regulatory intervention on nickel exposure.......Before the introduction of the EU Nickel Directive, concern was raised that manufacturers of jewellery might turn from the use of nickel to cobalt following the regulatory intervention on nickel exposure....

  9. Synthesis of new cobalt aluminophosphate framework by opening a cobalt methylphosphonate layered material

    Czech Academy of Sciences Publication Activity Database

    Zaarour, M.; Pérez, O.; Boullay, P.; Martens, J.; Mihailova, B.; Karaghiosoff, K.; Palatinus, Lukáš; Mintova, S.

    2017-01-01

    Roč. 19, č. 34 (2017), s. 5100-5105 ISSN 1466-8033 Institutional support: RVO:68378271 Keywords : cobalt aluminophosphate * cobalt methylphosphonate * layered materials * crystallic structure * X-ray diffraction Subject RIV: BM - Solid Matter Physics ; Magnetism OBOR OECD: Condensed matter physics (including formerly solid state physics, supercond.) Impact factor: 3.474, year: 2016

  10. AN ELECTROPLATING METHOD OF FORMING PLATINGS OF NICKEL, COBALT, NICKEL ALLOYS OR COBALT ALLOYS

    DEFF Research Database (Denmark)

    1997-01-01

    An electroplating method of forming platings of nickel, cobalt, nickel alloys or cobalt alloys with reduced stresses in an electrodepositing bath of the type: Watt's bath, chloride bath or a combination thereof, by employing pulse plating with periodic reverse pulse and a sulfonated naphthalene...

  11. Cobalt adsorption/desorption on sediments from Piraquara de Fora bay, Angra dos Reis, Brazil

    International Nuclear Information System (INIS)

    Ferreira, Ingryd M.; Carvalho, Franciane M.; Ribeiro, Fernando C.A.; Martins, Nadia S.F.; Peres, Sueli S.; Lauria, Dejanira C.

    2015-01-01

    Among the radionuclides released with the liquid effluents from PWR power plants, cobalt isotopes ( 60 Co and 58 Co) play an important role for risk and environmental impact assessments. The laboratory experiments on radionuclide adsorption-desorption, followed by the use of adsorption isotherms are useful tools for prediction of transport, distribution, accumulation, and fate of a contaminant into a specific medium. Adsorption and desorption experiments were carried out in batches, using two sediment samples collected in Piraquara de Fora Bay, near the discharge channel of the liquid effluents from CNAAA. Aiming the assessment of the radioisotope adsorption mechanisms, sediment samples were shaken with solutions containing cobalt chloride which concentrations ranged between 10 -10 and 10 -3 M. In order to estimate the efficiency of adsorption, 100 Bq of 60 Co were used as radioactive tracer. The experimental data fitted well with Freundlich and Langmuir isotherms. Results point out a favorable and high cobalt adsorption on the sediments, although smaller than the ones reported in literature studies. Such smaller trend of adsorption coefficients may be caused by the low exchange capacity of the prevailing clay, kaolinite. The maximum adsorption capacities were found to be 10 and 17 moles/g for sediments in PT-01 and PT-02, respectively. Values lower than 8% of the adsorbed cobalt underwent desorption and this amount decreased to 4%, with time, which show the high retention capacity of these sediments. (author)

  12. Control of carbon nanotube growth using cobalt nanoparticles as catalyst

    International Nuclear Information System (INIS)

    Huh, Yoon; Green, Malcolm L.H.; Kim, Young Heon; Lee, Jeong Yong; Lee, Cheol Jin

    2005-01-01

    We have controllably grown carbon nanotubes using uniformly distributed cobalt nanoparticles as catalyst. Cobalt nanoparticles with a uniform size were synthesized by chemical reaction and colloidal solutions including the cobalt nanoparticles were prepared. The cobalt nanoparticles were uniformly distributed on silicon substrates by a spin-coating method. Carbon nanotubes with a uniform diameter were synthesized on the cobalt nanoparticles by thermal chemical vapor deposition of acetylene gas. The density and vertical alignment of carbon nanotubes could be controlled by adjusting the density of cobalt (Co) nanoparticles

  13. Calcium-assisted reduction of cobalt ferrite nanoparticles for nanostructured iron cobalt with enhanced magnetic performance

    International Nuclear Information System (INIS)

    Qi, B.; Andrew, J. S.; Arnold, D. P.

    2017-01-01

    This paper demonstrates the potential of a calcium-assisted reduction process for synthesizing fine-grain (~100 nm) metal alloys from metal oxide nanoparticles. To demonstrate the process, an iron cobalt alloy (Fe_6_6Co_3_4) is obtained by hydrogen annealing 7-nm cobalt ferrite (CoFe_2O_4) nanoparticles in the presence of calcium granules. The calcium serves as a strong reducing agent, promoting the phase transition from cobalt ferrite to a metallic iron cobalt alloy, while maintaining high crystallinity. Magnetic measurements demonstrate the annealing temperature is the dominant factor of tuning the grain size and magnetic properties. Annealing at 700 °C for 1 h maximizes the magnetic saturation, up to 2.4 T (235 emu/g), which matches that of bulk iron cobalt.

  14. Calcium-assisted reduction of cobalt ferrite nanoparticles for nanostructured iron cobalt with enhanced magnetic performance

    Energy Technology Data Exchange (ETDEWEB)

    Qi, B. [University of Florida, Interdisciplinary Microsystems Group, Department of Electrical and Computer Engineering (United States); Andrew, J. S. [University of Florida, Department of Materials Science and Engineering (United States); Arnold, D. P., E-mail: darnold@ufl.edu [University of Florida, Interdisciplinary Microsystems Group, Department of Electrical and Computer Engineering (United States)

    2017-03-15

    This paper demonstrates the potential of a calcium-assisted reduction process for synthesizing fine-grain (~100 nm) metal alloys from metal oxide nanoparticles. To demonstrate the process, an iron cobalt alloy (Fe{sub 66}Co{sub 34}) is obtained by hydrogen annealing 7-nm cobalt ferrite (CoFe{sub 2}O{sub 4}) nanoparticles in the presence of calcium granules. The calcium serves as a strong reducing agent, promoting the phase transition from cobalt ferrite to a metallic iron cobalt alloy, while maintaining high crystallinity. Magnetic measurements demonstrate the annealing temperature is the dominant factor of tuning the grain size and magnetic properties. Annealing at 700 °C for 1 h maximizes the magnetic saturation, up to 2.4 T (235 emu/g), which matches that of bulk iron cobalt.

  15. Cobalt and vitamin B12 in diets for commercial laying hens on the second cycle of production

    Directory of Open Access Journals (Sweden)

    RK Kato

    2003-04-01

    Full Text Available The supplementation of cobalt and vitamin B12 in diets for commercial laying hens on the second production cycle was studied. Four hundred and eighty light commercial laying hens, Lohmann LSL, were used at initial phase of forced molting laying period. The trial was conducted in a randomized design. The plots were the treatments which were constituted by combination of five cobalt levels (0.00; 0.30; 0.60; 0.90 and 1.20ppm and two vitamin B12 levels (without and with 10µ/kg, and the split-plots were four periods (21, 42, 63 and 84 days during the second period of production, with 4 repetitions and 12 hens per experimental unit. Food and water were provided ad libitum and eggs were collected twice daily. Performance and egg quality parameters were evaluated. At the end of experimental period, two layers from each treatment were slaughtered, and liver and blood samples were taken for analysis. Performance and egg quality were not different (p>0.05 among cobalt supplementation levels, although egg damage data were different (p<0.05. Supplementation with vitamin B12 decreased egg weight. No influence of cobalt or vitamin B12 supplementation was seen on the concentration of cobalt in the liver and yolk as well as on blood analysis (hematrocrit, hemoglobin, erythrocytes, and leukocytes. The results revealed that vitamin B12 supplementation was important for commercial laying hens on the second cycle of production, but not cobalt supplementation.

  16. Synthesis of Samarium Cobalt Nanoblades

    Energy Technology Data Exchange (ETDEWEB)

    Darren M. Steele

    2010-08-25

    As new portable particle acceleration technologies become feasible the need for small high performance permanent magnets becomes critical. With particle accelerating cavities of a few microns, the photonic crystal fiber (PCF) candidate demands magnets of comparable size. To address this need, samarium cobalt (SmCo) nanoblades were attempted to be synthesized using the polyol process. Since it is preferable to have blades of 1-2 {micro}m in length, key parameters affecting size and morphology including method of stirring, reaction temperature, reaction time and addition of hydroxide were examined. Nanoparticles consisting of 70-200 nm spherical clusters with a 3-5 nm polyvinylpyrrolidone (PVP) coating were synthesized at 285 C and found to be ferromagnetic. Nanoblades of 25nm in length were observed at the surface of the nanoclusters and appeared to suggest agglomeration was occurring even with PVP employed. Morphology and size were characterized using a transmission electron microscope (TEM). Powder X-Ray Diffraction (XRD) analysis was conducted to determine composition but no supportive evidence for any particular SmCo phase has yet been observed.

  17. Set of devices for producing radioactive 60Co-sources

    International Nuclear Information System (INIS)

    Eichhorn, P.; Tobisch, F.

    1982-01-01

    A set of devices for producing radioactive 60 Co-sources was developed. A single source has a radioactivity of 445x10 10 GBq. It consists of a double envelope of stainless steel filled with a mixture of small pieces of cobalt and stainless steel wire. The diameter of a source is 11 mm; the length 80 mm. Cobalt wires of different radioactivity with a length of about 110 mm and 0,8 mm diameter are the raw material. The set is located in a hot cell. Construction, functions and operation of the set are described in detail. (author)

  18. Loss of hypoxia-inducible factor 2 alpha in the lung alveolar epithelium of mice leads to enhanced eosinophilic inflammation in cobalt-induced lung injury.

    Science.gov (United States)

    Proper, Steven P; Saini, Yogesh; Greenwood, Krista K; Bramble, Lori A; Downing, Nathaniel J; Harkema, Jack R; Lapres, John J

    2014-02-01

    Hard metal lung disease (HMLD) is an occupational lung disease specific to inhalation of cobalt-containing particles whose mechanism is largely unknown. Cobalt is a known hypoxia mimic and stabilizer of the alpha subunits of hypoxia-inducible factors (HIFs). Previous work revealed that though HIF1α contrib utes to cobalt toxicity in vitro, loss of HIF1α in the alveolar epithelial cells does not provide in vivo protection from cobalt-induced lung inflammation. HIF1α and HIF2α show unique tissue expression profiles, and HIF2α is known to be the predominant HIF mRNA isoform in the adult lung. Thus, if HIF2α activation by cobalt contributes to pathophysiology of HMLD, we hypothesized that loss of HIF2α in lung epithelium would provide protection from cobalt-induced inflammation. Mice with HIF2α-deficiency in Club and alveolar type II epithelial cells (ATIIs) (HIF2α(Δ/Δ)) were exposed to cobalt (60 µg/day) or saline using a subacute occupational exposure model. Bronchoalveolar lavage cellularity, cytokines, qRT-PCR, and histopathology were analyzed. Results show that loss of HIF2α leads to enhanced eosinophilic inflammation and increased goblet cell metaplasia. Additionally, control mice demonstrated a mild recovery from cobalt-induced lung injury compared with HIF2α(Δ/Δ) mice, suggesting a role for epithelial HIF2α in repair mechanisms. The expression of important cytokines, such as interleukin (IL)-5 and IL-10, displayed significant differences following cobalt exposure when HIF2α(Δ/Δ) and control mice were compared. In summary, our data suggest that although loss of HIF2α does not afford protection from cobalt-induced lung inflammation, epithelial HIF2α signaling does play an important role in modulating the inflammatory and repair response in the lung.

  19. Cobalt: A vital element in the aircraft engine industry

    Science.gov (United States)

    Stephens, J. R.

    1981-01-01

    Recent trends in the United States consumption of cobalt indicate that superalloys for aircraft engine manufacture require increasing amounts of this strategic element. Superalloys consume a lion's share of total U.S. cobalt usage which was about 16 million pounds in 1980. In excess of 90 percent of the cobalt used in this country was imported, principally from the African countries of Zaire and Zambia. Early studies on the roles of cobalt as an alloying element in high temperature alloys concentrated on the simple Ni-Cr and Nimonic alloy series. The role of cobalt in current complex nickel base superalloys is not well defined and indeed, the need for the high concentration of cobalt in widely used nickel base superalloys is not firmly established. The current cobalt situation is reviewed as it applies to superalloys and the opportunities for research to reduce the consumption of cobalt in the aircraft engine industry are described.

  20. Assessment of cobalt levels in wastewater, soil and vegetable ...

    African Journals Online (AJOL)

    User

    Key words: Cobalt level, Kubanni River, soil, vegetable, wastewater. INTRODUCTION. Cobalt is ... metals released into the environment from a variety of anthropogenic activities ..... Heavy Metal Stress in Plants, 2nd Edition,. Springer,. United.

  1. Synthesis and phosphatase activity of a Cobalt(II) phenanthroline ...

    Indian Academy of Sciences (India)

    MAMONI GARAI

    2017-09-19

    Sep 19, 2017 ... Synthesis and phosphatase activity of a Cobalt(II) phenanthroline complex. MAMONI GARAIa ... tion, cobalt complexes have gained importance because of their application as ... 2.3 Physical measurements. Infrared spectrum ...

  2. Cobalt-doped nanohydroxyapatite: synthesis, characterization, antimicrobial and hemolytic studies

    Energy Technology Data Exchange (ETDEWEB)

    Tank, Kashmira P., E-mail: kashmira_physics@yahoo.co.in [Saurashtra University, Crystal Growth Laboratory, Physics Department (India); Chudasama, Kiran S.; Thaker, Vrinda S. [Saurashtra University, Bioscience Department (India); Joshi, Mihir J., E-mail: mshilp24@rediffmail.com [Saurashtra University, Crystal Growth Laboratory, Physics Department (India)

    2013-05-15

    Hydroxyapatite (Ca{sub 10}(PO{sub 4}){sub 6}(OH){sub 2}; HAP) is a major mineral component of the calcified tissues, and it has various applications in medicine and dentistry. In the present investigation, cobalt-doped hydroxyapatite (Co-HAP) nanoparticles were synthesized by surfactant-mediated approach and characterized by different techniques. The EDAX was carried out to estimate the amount of doping in Co-HAP. The transmission electron microscopy result suggested the transformation of morphology from needle shaped to spherical type on increasing the doping concentration. The powder XRD study indicated the formation of a new phase of brushite for higher concentration of cobalt. The average particle size and strain were calculated using Williamson-Hall analysis. The average particle size was found to be 30-60 nm. The FTIR study confirmed the presence of various functional groups in the samples. The antimicrobial activity was evaluated against four organisms Pseudomonas aeruginosa and Shigella flexneri as Gram negative as well as Micrococcus luteus and Staphylococcus aureus as Gram positive. The hemolytic test result suggested that all samples were non-hemolytic. The photoluminescence study was carried out to identify its possible applicability as a fluorescent probe.

  3. Cobalt-doped nanohydroxyapatite: synthesis, characterization, antimicrobial and hemolytic studies

    International Nuclear Information System (INIS)

    Tank, Kashmira P.; Chudasama, Kiran S.; Thaker, Vrinda S.; Joshi, Mihir J.

    2013-01-01

    Hydroxyapatite (Ca 10 (PO 4 ) 6 (OH) 2 ; HAP) is a major mineral component of the calcified tissues, and it has various applications in medicine and dentistry. In the present investigation, cobalt-doped hydroxyapatite (Co-HAP) nanoparticles were synthesized by surfactant-mediated approach and characterized by different techniques. The EDAX was carried out to estimate the amount of doping in Co-HAP. The transmission electron microscopy result suggested the transformation of morphology from needle shaped to spherical type on increasing the doping concentration. The powder XRD study indicated the formation of a new phase of brushite for higher concentration of cobalt. The average particle size and strain were calculated using Williamson–Hall analysis. The average particle size was found to be 30–60 nm. The FTIR study confirmed the presence of various functional groups in the samples. The antimicrobial activity was evaluated against four organisms Pseudomonas aeruginosa and Shigella flexneri as Gram negative as well as Micrococcus luteus and Staphylococcus aureus as Gram positive. The hemolytic test result suggested that all samples were non-hemolytic. The photoluminescence study was carried out to identify its possible applicability as a fluorescent probe.

  4. Relaxation resistance of heat resisting alloys with cobalt

    International Nuclear Information System (INIS)

    Borzdyka, A.M.

    1977-01-01

    Relaxation resistance of refractory nickel-chromium alloys containing 5 to 14 % cobalt is under study. The tests involve the use of circular samples at 800 deg to 850 deg C. It is shown that an alloy containing 14% cobalt possesses the best relaxation resistance exceeding that of nickel-chromium alloys without any cobalt by a factor of 1.5 to 2. The relaxation resistance of an alloy with 5% cobalt can be increased by hardening at repeated loading

  5. Manipulating radicals: Using cobalt to steer radical reactions

    OpenAIRE

    Chirilă, A.

    2017-01-01

    This thesis describes research aimed at understanding and exploiting metallo-radical reactivity and explores reactions mediated by square planar, low-spin cobalt(II) complexes. A primary goal was to uncover novel reactivity of discrete cobalt(III)-bound carbene radicals generated upon reaction of the cobalt(II) catalysts with carbene precursors. Another important goal was to replace cobalt(II)-porphyrin catalysts with cheaper and easier to prepare metallo-radical analogues. Therefore the cata...

  6. Cobalt as a gastric juice volume marker: Comparison of two methods of estimation

    International Nuclear Information System (INIS)

    Gana, T.J.; MacPherson, B.R.; Ng, D.; Koo, J.

    1990-01-01

    We investigated the use of cobalt-EDTA, a novel, nonabsorbable liquid phase marker, in the estimation of secretory volumes during topical misoprostol (synthetic PGE, analog) administration in the canine chambered gastric segment. We compared atomic absorption spectrophotometry (AAS) and instrumental neutron activation analysis (INAA) in the estimation of [Co]. Mucosal bathing solutions containing cobalt-EDTA were instilled into and recovered from the chamber by gravity every 15-min period as follows: (i) basal--60 min; (ii) misoprostol periods--150 min (plus 0.1-, 1-, 10-, 100-, and 1000-micrograms doses of misoprostol for two periods per dose). The recovered solutions were analyzed for [Co] by AAS and INAA. Total cobalt recovery by AAS after chamber washout was 102.97 +/- 0.98%. Mean +/- SE volumes (12.14 +/- 0.33 and 13.24 +/- 0.60 ml/15 min) obtained respectively from AAS and INAA were significantly higher (P less than 0.001) than the recovered mean volumes (10.51 +/- 0.17 ml/15 min). The percentage error in volume collection increased (range: 9.3-52.7%) with the volume of secretion. Values of [Co] obtained by the two techniques were comparable and not significantly different from each other (P greater than 0.05). INAA-estimated mean +/- SE [Co] showed consistently higher coefficients of variation. Spectra obtained for all samples during INAA measurements showed significant Compton background activity from 24Na and 38Cl. Cobalt-EDTA did not grossly or histologically damage the gastric mucosa. We conclude that cobalt is not adsorbed, absorbed, or metabolized, and is a suitable and reliable volume marker in this model

  7. Perfluorinated cobalt phthalocyanine effectively catalyzes water electrooxidation

    KAUST Repository

    Morlanes, Natalia Sanchez

    2014-12-08

    Efficient electrocatalysis of water oxidation under mild conditions at neutral pH was achieved by a fluorinated cobalt phthalocyanine immobilized on fluorine-doped tin oxide (FTO) surfaces with an onset potential at 1.7 V vs. RHE. Spectroscopic, electrochemical, and inhibition studies indicate that phthalocyanine molecular species are the operational active sites. Neither free cobalt ions nor heterogeneous cobalt oxide particles or films were observed. During long-term controlled-potential electrolysis at 2 V vs. RHE (phosphate buffer, pH 7), electrocatalytic water oxidation was sustained for at least 8 h (TON ≈ 1.0 × 105), producing about 4 μmol O2 h-1 cm-2 with a turnover frequency (TOF) of about 3.6 s-1 and no measurable catalyst degradation.

  8. Characterization of a Cobalt-Tungsten Interconnect

    DEFF Research Database (Denmark)

    Harthøj, Anders; Holt, Tobias; Caspersen, Michael

    2012-01-01

    is to act both as a diffusion barrier for chromium and provide better protection against high temperature oxidation than a pure cobalt coating. This work presents a characterization of a cobalt-tungsten alloy coating electrodeposited on the ferritic steel Crofer 22 H which subsequently was oxidized in air......A ferritic steel interconnect for a solid oxide fuel cell must be coated in order to prevent chromium evaporation from the steel substrate. The Technical University of Denmark and Topsoe Fuel Cell have developed an interconnect coating based on a cobalt-tungsten alloy. The purpose of the coating...... for 300 h at 800 °C. The coating was characterized with Glow Discharge Optical Spectroscopy (GDOES), Scanning Electron Microscopy (SEM) and X-Ray Diffraction (XRD). The oxidation properties were evaluated by measuring weight change of coated samples of Crofer 22 H and Crofer 22 APU as a function...

  9. Solubility of cobalt in primary circuit solutions

    International Nuclear Information System (INIS)

    Lambert, I.; Joyer, F.

    1992-01-01

    The solubility of cobalt ferrite (CoFe 2 O 4 ) was measured in PWR primary circuit conditions, in the temperature range 250-350 deg C, and the results were compared with the ones obtained on magnetite and nickel ferrite. As in the former cases, it was found that, in the prevailing primary circuit conditions, the solubility of the cobalt ferrite was minimum at temperatures around 300 deg C, for cobalt as well as for iron. The equilibrium iron concentration is significantly lower than in the case of magnetite. The results are discussed in relation with the POTHY code, based only on thermodynamic laws and data, used for the prediction of the primary circuit chemistry

  10. Palladium-cobalt particles as oxygen-reduction electrocatalysts

    Science.gov (United States)

    Adzic, Radoslav [East Setauket, NY; Huang, Tao [Manorville, NY

    2009-12-15

    The present invention relates to palladium-cobalt particles useful as oxygen-reducing electrocatalysts. The invention also relates to oxygen-reducing cathodes and fuel cells containing these palladium-cobalt particles. The invention additionally relates to methods for the production of electrical energy by using the palladium-cobalt particles of the invention.

  11. 21 CFR 73.1015 - Chromium-cobalt-aluminum oxide.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 1 2010-04-01 2010-04-01 false Chromium-cobalt-aluminum oxide. 73.1015 Section 73... LISTING OF COLOR ADDITIVES EXEMPT FROM CERTIFICATION Drugs § 73.1015 Chromium-cobalt-aluminum oxide. (a) Identity. The color additive chromium-cobalt-aluminum oxide is a blue-green pigment obtained by calcining a...

  12. Radiation induced ligand loss from cobalt complexes

    International Nuclear Information System (INIS)

    Funston, A. M.; McFadyen, W.D.; Tregloan, P.A.

    2000-01-01

    Full text: Due to the rapid nature of ligand dissociation from cobalt(II) complexes the study of the rate of ligand dissociation necessitates the use of a technique such as pulse radiolysis. This allows the rapid reduction of the corresponding cobalt(III) complex by a reducing radical, such as the aquated electron, to form the cobalt(II) complex. However, to date, no systematic study of either the mechanism of reduction or the influence of the electronic structure on the rate of ligand dissociation has been carried out. In order to understand these processes more fully the mechanism of reduction of a range of related cobalt(III) complexes by the aquated electron and the subsequent rate of ligand dissociation from the resulting cobalt(II) complexes is being investigated. It has been found that a number of processes are observed following the initial rapid reaction of the cobalt(III) complex with the aquated electron. Ultimately ligand loss is observed. Depending upon the complex, the initial processes observed may include the formation of coordinated radicals and electron transfer within the complex. For complexes containing aromatic ligands such as 2,2'-bipyridine, 1,10-phenanthroline and dipyrido[3,2-a:2',3'-c]phenazine the formation of a coordinated radical is observed as the initial reduction step. The kinetics of ligand dissociation of these complexes has been determined. The loss of monodentate ligands is fast and has been indistinguishable from the reduction processes when aromatic ligands are also present in the complex. However, for diamine chelates and diimine chelates spectra of the transient species can be resolved

  13. Cation distributions on rapidly solidified cobalt ferrite

    Science.gov (United States)

    De Guire, Mark R.; Kalonji, Gretchen; O'Handley, Robert C.

    1990-01-01

    The cation distributions in two rapidly solidified cobalt ferrites have been determined using Moessbauer spectroscopy at 4.2 K in an 8-T magnetic field. The samples were obtained by gas atomization of a Co0-Fe2O3-P2O5 melt. The degree of cation disorder in both cases was greater than is obtainable by cooling unmelted cobalt ferrite. The more rapidly cooled sample exhibited a smaller departure from the equilibrium cation distribution than did the more slowly cooled sample. This result is explained on the basis of two competing effects of rapid solidification: high cooling rate of the solid, and large undercooling.

  14. Utilisation of gamma radiation of Cobalt-60 as quarantine treatment of medicinal plant, aromatic and seasoning plants dehydrated infested by Lasioderma serricorne (Fabricius, 1792) (Coleoptera, Anobiidae) and Plodia interpunctella (Hubner, 1813) (Lepidoptera, Pyralidae); Utilizacao da radiacao gama do Cobalto-60 como tratamento quarentenario de plantas medicinais, aromaticas e condimentares desidratadas infestadas por Lasioderma serricorne (Fabricius, 1792) (Coleoptera, Anobiidae) e Plodia interpunctella (Hubner, 1813) (Lepidoptera, Pyralidae)

    Energy Technology Data Exchange (ETDEWEB)

    Alves, Juliana Nazare

    2007-07-01

    The research had as objective the use of the gamma radiation of the Cobalto-60 as quarantine treatment of the medicinal plant, aromatic and seasoning plants dehydrated infested by Lasioderma serricorne and Plodia interpunctella determining the disinfestation doses to attend the criterion in the not emergency of adults of the species in study and analysing through the Chromatography of Thin Layer the effect of the gamma radiation of the cobalto-60 on the active principle of extract dehydrated of Chamomilla recutita, Pimpinella anisum, Origanum vulgare, Cymbopogon citratus, Ocimum basilicum and Thymus vulgaris. The work was developed in the Laboratorio de Inseticidas in the Instituto Biologico in Sao Paulo in the period of August of 2005 the June of 2007. The radiation source used gamma was an experimental irradiator of Cobalto-60, model Gamacell 220, located in the Instituto de Pesquisas Energeticas e Nucleares - IPEN, located in Sao Paulo. In the period of 30 days after the irradiation of the samples evaluated the number of adults emerged of Lasioderma serricorne and Plodia interpunctella, using the data of mortality for the analysis of Probit. Obtained 100% of not emergency of adults in the Lasioderma serricorne with the dose of 2,00 kGy and 100% of not emergency of adults in the Plodia interpunctella with the dose of 2,25 kGy. The Chromatographic Analysis of Thin Layer was to evaluate did not show chemical differences in the extracts analysed. (author)

  15. Equilibrium sorption of cobalt, cesium, and strontium on Bandelier Tuff: analysis of alternative mathematical modeling

    International Nuclear Information System (INIS)

    Polzer, W.L.; Fuentes, H.R.; Essington, E.H.; Roensch, F.R.

    1985-01-01

    Sorption isotherms are derived from batch equilibrium data for cobalt, cesium and strontium on Bandelier Tuff. Experiments were conducted at an average temperature of 23 0 C and equilibrium was defined at 48 hours. The solute concentrations ranged from 0 to 500 mg/L. The radioactive isotopes 60 Co, 137 Cs, and 85 Sr were used to trace the sorption of the stable solutes. The Linear, Langmuir, Freundlich and a Modified Freundlich isotherm equations are evaluated. The Modified Freundlich isotherm equation is validated as a preferred general mathematical tool for representing the sorption of the three solutes. The empirical constants derived from the Modified Freundlich isotherm equation indicate that under dynamic flow conditions strontium will move most rapidly and cobalt least rapidly. On the other hand, chemical dispersion will be greatest for cesium and least for strontium. Hill Plots of the sorption data suggest that in the region of low saturation sorption of all three solutes is impeded by interactions among sorption sites; cobalt exhibits the greatest effect of interactions and strontium shows only a minimal effect. In the saturation region of 50% or more, sorption of cobalt is enhanced slightly by interactions among sorption sites whereas sorption of cesium and strontium appears to be independent of site interactions. 9 references, 4 figures, 2 tables

  16. Recovery of lithium and cobalt from waste lithium ion batteries of mobile phone.

    Science.gov (United States)

    Jha, Manis Kumar; Kumari, Anjan; Jha, Amrita Kumari; Kumar, Vinay; Hait, Jhumki; Pandey, Banshi Dhar

    2013-09-01

    In view of the stringent environmental regulations, availability of limited natural resources and ever increasing need of alternative energy critical elements, an environmental eco-friendly leaching process is reported for the recovery of lithium and cobalt from the cathode active materials of spent lithium-ion batteries of mobile phones. The experiments were carried out to optimize the process parameters for the recovery of lithium and cobalt by varying the concentration of leachant, pulp density, reductant volume and temperature. Leaching with 2M sulfuric acid with the addition of 5% H(2)O(2) (v/v) at a pulp density of 100 g/L and 75°C resulted in the recovery of 99.1% lithium and 70.0% cobalt in 60 min. H(2)O(2) in sulfuric acid solution acts as an effective reducing agent, which enhance the percentage leaching of metals. Leaching kinetics of lithium in sulfuric acid fitted well to the chemical controlled reaction model i.e. 1-(1-X)(1/3)=k(c)t. Leaching kinetics of cobalt fitted well to the model 'ash diffusion control dense constant sizes spherical particles' i.e. 1-3(1-X)(2/3)+2(1-X)=k(c)t. Metals could subsequently be separated selectively from the leach liquor by solvent extraction process to produce their salts by crystallization process from the purified solution. Copyright © 2013 Elsevier Ltd. All rights reserved.

  17. EXAFS Determination of the Structure of Cobalt in Carbon-Supported Cobalt and Cobalt-Molybdenum Sulfide Hydrodesulfurization Catalysts.

    NARCIS (Netherlands)

    Koningsberger, D.C.; Bouwens, S.M.A.M.; Veen, J.A.R. van; Beer, V.H.J. de; Prins, R.

    1991-01-01

    The structure of the cobalt present in carbon-supported Co and Co-Mo sulfide catalysts was studied by means of X-ray absorption spectroscopy at the Co K-edge and by X-ray photoelectron spectroscopy (XPS). Thiophene hydrodesulfurization activities were used to measure the catalytic properties of

  18. Reduction of Nitrogen Oxides using zeolite catalysts exchanged with cobalt

    International Nuclear Information System (INIS)

    Garcia M, E.A.; Bustamante L, F.; Montes de C, C.

    1999-01-01

    The Selective Catalytic Reduction (SCR) of NOx by methane in excess oxygen was studied over several zeolite catalysts; namely cobalt loaded mordenite, ferrierite, SM-5 and the corresponding acid forms. When NO2 predominated n the NOx mixture the acid forms showed the highest N2 formation rates under dry conditions. Mordenite supported catalysts were the most active ones followed by ferrierite and ZSM-5. The most active Co-Mordenite catalyst was tested using a NOx mixture, containing mostly NO, under dry conditions and in the presence of water and SO2. The addition of 8 % water to the reaction mixture lead to a reversible deactivation, mainly at low temperatures. When the reaction mixture contained 60 ppm SO2, the N2 formation rate decreased about a half likely due to SO2 poisoning

  19. Magnetic properties engineering of nanopatterned cobalt antidot arrays

    International Nuclear Information System (INIS)

    Kaidatzis, Andreas; Niarchos, Dimitrios; Del Real, Rafael P; Vázquez, Manuel; Alvaro, Raquel; Anguita, José; García-Martín, José Miguel; Luis Palma, Juan; Escrig, Juan

    2016-01-01

    We report on the study of arrays of 60 nm wide cobalt antidots, nanopatterned using focused ion beam milling. Square and hexagonal symmetry arrays have been studied, with varying antidot densities and lattice constant from 150 up to 300 nm. We find a strong increase of the arrays’ magnetic coercivity with respect to the unpatterned film, which is monotonic as the antidot density increases. Additionally, there is a strong influence of the array symmetry to the in-plane magnetic anisotropy: square arrays exhibit fourfold symmetry and hexagonal arrays exhibit sixfold symmetry. The above findings are corroborated by magnetic imaging and micromagnetic modeling, which show the magnetic structure of the arrays to depend strongly on the array morphology. (paper)

  20. Effect of cyanide on the distribution of 60Co in mice

    International Nuclear Information System (INIS)

    Frankenberg, L.

    1982-01-01

    The effect of cyanide on the distribution of cobalt was studied by injecting mice i.p. with potassium cyanide 61.4 μmoles/kg, followed 1 min later by 60 CoCl 2 38.5 μmoles/kg i.v. Blood and tissue concentrations of 60 Co were then determined up to 48 h after injection and the results were compared with those obtained from control animals receiving 60 CoCl 2 only. In animals treated with cobalt plus cyanide, considerably higher concentrations of 60 Co were found in the spleen in comparison with controls during the whole observation period, whereas the 60 Co concentration in the pancreas was lower than that of controls during the first 4 h. In other tissues no significant differences between cyanide-treated animals and controls were noticed. Determination of complex-bound cyanide demonstrated that the increased uptake of cobalt in the spleen observed in cyanide-treated animals was due to cobalt-cyanide complex(es). Cyanide did not affect the plasma protein binding of cobalt. (orig.)

  1. Passivation and corrosion behaviours of cobalt and cobalt-chromium-molybdenum alloy

    International Nuclear Information System (INIS)

    Metikos-Hukovic, M.; Babic, R.

    2007-01-01

    Passivation and corrosion behaviour of the cobalt and cobalt-base alloy Co30Cr6Mo was studied in a simulated physiological solution containing chloride and bicarbonate ions and with pH of 6.8. The oxido-reduction processes included solid state transformations occurring at the cobalt/electrolyte interface are interpreted using theories of surface electrochemistry. The dissolution of cobalt is significantly suppressed by alloying it with chromium and molybdenum, since the alloy exhibited 'chromium like' passivity. The structural and protective properties of passive oxide films formed spontaneously at the open circuit potential or during the anodic polarization were studied using electrochemical impedance spectroscopy in the wide frequency range

  2. Monte Carlo study of MLC fields for cobalt therapy machine

    Directory of Open Access Journals (Sweden)

    Komanduri M Ayyangar

    2014-01-01

    Full Text Available An automated Multi-Leaf Collimator (MLC system has been developed as add-on for the cobalt-60 teletherapy machines available in India. The goal of the present computational study is to validate the MLC design using Monte Carlo (MC modeling. The study was based on the Kirloskar-supplied Phoenix model machines that closely match the Atomic Energy of Canada Limited (AECL theratron-80 machine. The MLC is a retrofit attachment to the collimator assembly, with 14 non-divergent leaf pairs of 40 mm thick, 7 mm wide, and 150 mm long tungsten alloy plates with rounded edges and 20 mm tongue and 2 mm groove in each leaf. In the present work, the source and collimator geometry has been investigated in detail to arrive at a model that best represents the measured dosimetric data. The authors have studied in detail the proto-I MLC built for cobalt-60. The MLC field sizes were MC simulated for 2 × 2 cm 2 to 14 × 14 cm 2 square fields as well as irregular fields, and the percent depth dose (PDD and profile data were compared with ROPS† treatment planning system (TPS. In addition, measured profiles using the IMATRIXX system‡ were also compared with the MC simulations. The proto-I MLC can define radiation fields up to 14 × 14 cm΂ within 3 mm accuracy. The maximum measured leakage through the leaf ends in closed condition was 3.4% and interleaf leakage observed was 7.3%. Good agreement between MC results, ROPS and IMATRIXX results has been observed. The investigation also supports the hypothesis that optical and radiation field coincidence exists for the square fields studied with the MLC. Plots of the percent depth dose (PDD data and profile data for clinically significant irregular fields have also been presented. The MC model was also investigated to speed up the calculations to allow calculations of clinically relevant conformal beams.

  3. Water splitting: Taking cobalt in isolation

    Science.gov (United States)

    Wang, Aiqin; Zhang, Tao

    2016-01-01

    The sustainable production of hydrogen is key to the delivery of clean energy in a hydrogen economy; however, lower-cost alternatives to platinum electrocatalysts are needed. Now, isolated, earth-abundant cobalt atoms dispersed over nitrogen-doped graphene are shown to efficiently electrolyse water to generate hydrogen.

  4. Synthesis and Characterization of Cobalt Ferrite Nanoparticles ...

    African Journals Online (AJOL)

    prepared material. It was observed that surface modification such as with silica coating on the cobalt ferrite will have significant effect on the structural and magnetic properties. It is also observed that, silica coated nanoparticles could be used in biomedical applications (Hong et al., 2013). In this work we have chosen sol-gel ...

  5. Nano cobalt oxides for photocatalytic hydrogen production

    KAUST Repository

    Mangrulkar, Priti A.

    2012-07-01

    Nano structured metal oxides including TiO 2, Co 3O 4 and Fe 3O 4 have been synthesized and evaluated for their photocatalytic activity for hydrogen generation. The photocatalytic activity of nano cobalt oxide was then compared with two other nano structured metal oxides namely TiO 2 and Fe 3O 4. The synthesized nano cobalt oxide was characterized thoroughly with respect to EDX and TEM. The yield of hydrogen was observed to be 900, 2000 and 8275 mmol h -1 g -1 of photocatalyst for TiO 2, Co 3O 4 and Fe 3O 4 respectively under visible light. It was observed that the hydrogen yield in case of nano cobalt oxide was more than twice to that of TiO 2 and the hydrogen yield of nano Fe 3O 4 was nearly four times as compared to nano Co 3O 4. The influence of various operating parameters in hydrogen generation by nano cobalt oxide was then studied in detail. Copyright © 2012, Hydrogen Energy Publications, LLC. Published by Elsevier Ltd. All rights reserved.

  6. Sputtering on cobalt with noble gas ions

    International Nuclear Information System (INIS)

    Sarholt-Kristensen, L.; Johansen, A.; Johnson, E.

    1983-01-01

    Single crystals of cobalt have been bombarded with 80 keV Ar + ions and with 80 keV and 200 keV Xe + ions in the [0001] direction of the hcp phase and the [111] direction of the fcc phase. The sputtering yield has been measured as function of target temperature (20 0 C-500 0 C), showing a reduction in sputtering yield for 80 keV Ar + ions and 200 keV Xe + ions, when the crystal structure changes from hcp to fcc. In contrast to this, bombardment with 80 keV Xe + ions results in an increase in sputtering yield as the phase transition is passed. Sputtering yields for [111] nickel are in agreement with the sputtering yields for fcc cobalt indicating normal behaviour of the fcc cobalt phase. The higher sputtering yield of [0001] cobalt for certain combinations of ion mass and energy may then be ascribed to disorder induced partly by martensitic phase transformation, partly by radiation damage. (orig.)

  7. Monte Carlo estimation of the dose and heating of cobalt adjuster rods irradiated in the CANDU 6 reactor core

    International Nuclear Information System (INIS)

    Gugiu, D.; Dumitrache, I.

    2005-01-01

    The present work is a part of a more complex project related to the replacement of the original stainless steel adjuster rods with cobalt assemblies in the CANDU 6 reactor core. The 60 Co produced by 59 Co irradiation could be used extensively in medicine and industry. The paper will mainly describe some of the reactor physics and safety requirements that must be carried into practice for the Co adjuster rods. The computations related to the neutronic equivalence of the stainless steel adjusters with the Co adjuster assemblies, as well as the estimations of the activity and heating of the irradiated cobalt rods, are performed using the Monte Carlo codes MCNP5 and MONTEBURNS 2.1. The activity values are used to evaluate the dose at the surface of the device designed to transport the cobalt adjusters. (authors)

  8. Speciation of cobalt-chloride-based ionic liquids and electrodeposition of Co wires

    International Nuclear Information System (INIS)

    Hsieh, Yi-Ting; Lai, Mei-Chun; Huang, Hsin-Liang; Sun, I.-Wen

    2014-01-01

    Highlights: • Template-free electrodeposition of cobalt nanowires arrays can be achieved from Lewis acidic CoCl 2 -EMIC ionic liquids. • SEM and TEM images reveal the diameter of the nanowire is around 200 nm, and the XPS data shows that cobalt oxide is formed at the surface of the nanowire. • MALDI-TOF-MS, XAS, and UV-vis spectroscopy results show that the coordination number and the mean Co-Cl bond length are depending on the molar ratio of CoCl 2 and EMIC. - Abstract: The speciation and coordination of cobalt-chloride-based ionic liquids with various mole percentages of CoCl 2 were investigated using matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF-MS), X-ray absorption spectroscopy (XAS), ultraviolet-visible absorption spectroscopy, and cyclic voltammetry. The coordination number and the mean Co-Cl bond length decreases with increasing CoCl 2 concentration, indicating that various Co(II) chloride compounds such as CoCl 4 2- , Co 2 Cl 5 - , and Co 3 Cl 7 − are formed depending on the molar ratio of CoCl 2 and EMIC in the melt. While the [CoCl 4 ] 2− complex formed in the Lewis basic melts and is electrochemically inactive within the electrochemical window of the melt, the other coordination-unsaturated cobalt chloride compounds formed in Lewis acidic melts can be electrochemically reduced to cobalt metal. The template-free electrodeposition of Co nanowires can be achieved from 40-60 mol% and 50-50 mol% CoCl 2 -EMIC (1-ethyl-3-methylimidazolium chloride) ionic liquids without any additives. Scanning electron microscopy (SEM), transmission electron microscopy (TEM), and X-ray photoelectron spectroscopy (XPS) were used to characterize the surface of the deposits

  9. A thermodynamic and kinetic study of trace iron removal from aqueous cobalt sulfate solutions using Monophos resin.

    Science.gov (United States)

    Wang, Guangxin; Zhao, Yunchao; Yang, Bin; Song, Yongfa

    2018-01-01

    High purity cobalt has many important applications, such as magnetic recording media, magnetic recording heads, optoelectronic devices, magnetic sensors, and integrated circuits, etc. To produce 5N or higher purity cobalt in an electro-refining process, one of the challenges is to effectively reduce the Fe content of aqueous cobalt salt solution before electrolysis. This paper describes thermodynamic and kinetic investigations of the Fe adsorption process of a new sulfonated monophosphonic resin with the trade mark Monophos. Five cobalt sulfate solutions of different Co concentrations were prepared. Fe ions were removed from the solutions by ion exchange method using Monophos resin. Chemical analysis was carried out using a Perkin Elmer ICP-OES. The initial Fe concentrations of about 0.9-2.0 mg/L can be reduced to about 0.3-0.8 mg/L, which is equivalent to an Fe removal rate of 60-67%. The Langmuir isothermal adsorption model applies well to the Fe removal process. A second-order type based on McKay equation fits better with experimental data than other kinetic models. The kinetic curve can be divided into two sections. For t 30 min. Monophos resin is effective for the removal of trace Fe from cobalt sulfate solution. This ion exchange process obeys the Langmuir isothermal adsorption model and the McKay equation of second-order kinetics.

  10. Treatment of radioactive liquid waste (Co-60) by sorption on Zeolite Na-A prepared from Iraqi kaolin.

    Science.gov (United States)

    Mustafa, Yasmen A; Zaiter, Maysoon J

    2011-11-30

    Iraqi synthetic zeolite type Na-A has been suggested as ion exchange material to treat cobalt-60 in radioactive liquid waste which came from neutron activation for corrosion products. Batch experiments were conducted to find out the equilibrium isotherm for source sample. The equilibrium isotherm for radioactive cobalt in the source sample showed unfavorable type, while the equilibrium isotherm for the total cobalt (the radioactive and nonradioactive cobalt) in the source sample showed a favorable type. The ability of Na-A zeolite to remove cobalt from wastewater was checked for high cobalt concentration (822 mg/L) in addition to low cobalt concentration in the source sample (0.093 mg/L). A good fitting for the experimental data with Langmuir equilibrium model was observed. Langmuir constant qm which is related to monolayer adsorption capacity for low and high cobalt concentration was determined to be 0.021 and 140 mg/g(zeolite). The effects of important design variables on the zeolite column performance were studied these include initial concentration, flow rate, and bed depth. The experimental results have shown that high sorption capacity can be obtained at high influent concentration, low flow rate, and high bed depth. Higher column performance was obtained at higher bed depth. Thomas model was employed to predict the breakthrough carves for the above variables. A good fitting was observed with correlation coefficients between 0.915 and 0.985. Copyright © 2011 Elsevier B.V. All rights reserved.

  11. Recovery of lithium and cobalt from waste lithium ion batteries of mobile phone

    Energy Technology Data Exchange (ETDEWEB)

    Jha, Manis Kumar, E-mail: mkjha@nmlindia.org; Kumari, Anjan; Jha, Amrita Kumari; Kumar, Vinay; Hait, Jhumki; Pandey, Banshi Dhar

    2013-09-15

    Graphical abstract: Recovery of valuable metals from scrap batteries of mobile phone. - Highlights: • Recovery of Co and Li from spent LIBs was performed by hydrometallurgical route. • Under the optimum condition, 99.1% of lithium and 70.0% of cobalt were leached. • The mechanism of the dissolution of lithium and cobalt was studied. • Activation energy for lithium and cobalt were found to be 32.4 kJ/mol and 59.81 kJ/mol, respectively. • After metal recovery, residue was washed before disposal to the environment. - Abstract: In view of the stringent environmental regulations, availability of limited natural resources and ever increasing need of alternative energy critical elements, an environmental eco-friendly leaching process is reported for the recovery of lithium and cobalt from the cathode active materials of spent lithium-ion batteries of mobile phones. The experiments were carried out to optimize the process parameters for the recovery of lithium and cobalt by varying the concentration of leachant, pulp density, reductant volume and temperature. Leaching with 2 M sulfuric acid with the addition of 5% H{sub 2}O{sub 2} (v/v) at a pulp density of 100 g/L and 75 °C resulted in the recovery of 99.1% lithium and 70.0% cobalt in 60 min. H{sub 2}O{sub 2} in sulfuric acid solution acts as an effective reducing agent, which enhance the percentage leaching of metals. Leaching kinetics of lithium in sulfuric acid fitted well to the chemical controlled reaction model i.e. 1 − (1 − X){sup 1/3} = k{sub c}t. Leaching kinetics of cobalt fitted well to the model ‘ash diffusion control dense constant sizes spherical particles’ i.e. 1 − 3(1 − X){sup 2/3} + 2(1 − X) = k{sub c}t. Metals could subsequently be separated selectively from the leach liquor by solvent extraction process to produce their salts by crystallization process from the purified solution.

  12. The cytotoxicity and genotoxicity of soluble and particulate cobalt in human lung fibroblast cells

    Energy Technology Data Exchange (ETDEWEB)

    Smith, Leah J.; Holmes, Amie L. [Wise Laboratory of Environmental and Genetic Toxicology, University of Southern Maine, 96 Falmouth St., P.O. Box 9300, Portland, ME 04101-9300 (United States); Maine Center for Environmental Toxicology and Health, University of Southern Maine, 96 Falmouth St., P.O. Box 9300, Portland, ME 04101-9300 (United States); Department of Applied Medical Science, University of Southern Maine, 96 Falmouth St., P.O. Box 9300, Portland, ME 04101-9300 (United States); Kandpal, Sanjeev Kumar; Mason, Michael D. [Department of Chemical and Biological Engineering, University of Maine, Orono, ME (United States); Zheng, Tongzhang [Department of Environmental Health Sciences, Yale School of Public Health, New Haven, CT (United States); Wise, John Pierce, E-mail: John.Wise@usm.maine.edu [Wise Laboratory of Environmental and Genetic Toxicology, University of Southern Maine, 96 Falmouth St., P.O. Box 9300, Portland, ME 04101-9300 (United States); Maine Center for Environmental Toxicology and Health, University of Southern Maine, 96 Falmouth St., P.O. Box 9300, Portland, ME 04101-9300 (United States); Department of Applied Medical Science, University of Southern Maine, 96 Falmouth St., P.O. Box 9300, Portland, ME 04101-9300 (United States)

    2014-08-01

    Cobalt exposure is increasing as cobalt demand rises worldwide due to its use in enhancing rechargeable battery efficiency, super-alloys, and magnetic products. Cobalt is considered a possible human carcinogen with the lung being a primary target. However, few studies have considered cobalt-induced toxicity in human lung cells. Therefore, in this study, we sought to determine the cytotoxicity and genotoxicity of particulate and soluble cobalt in human lung cells. Cobalt oxide and cobalt chloride were used as representative particulate and soluble cobalt compounds, respectively. Exposure to both particulate and soluble cobalt induced a concentration-dependent increase in cytotoxicity, genotoxicity, and intracellular cobalt ion levels. Based on intracellular cobalt ion levels, we found that soluble cobalt was more cytotoxic than particulate cobalt while particulate and soluble cobalt induced similar levels of genotoxicity. However, soluble cobalt induced cell cycle arrest indicated by the lack of metaphases at much lower intracellular cobalt concentrations compared to cobalt oxide. Accordingly, we investigated the role of particle internalization in cobalt oxide-induced toxicity and found that particle-cell contact was necessary to induce cytotoxicity and genotoxicity after cobalt exposure. These data indicate that cobalt compounds are cytotoxic and genotoxic to human lung fibroblasts, and solubility plays a key role in cobalt-induced lung toxicity. - Highlights: • Particulate and soluble cobalt are cytotoxic and genotoxic to human lung cells. • Soluble cobalt induces more cytotoxicity compared to particulate cobalt. • Soluble and particulate cobalt induce similar levels of genotoxicity. • Particle-cell contact is required for particulate cobalt-induced toxicity.

  13. The development of 60Co γ knife therapy sources

    International Nuclear Information System (INIS)

    Wu Rihua; Li Xingyi; Wu Guihua; Xia Bing; Zhang Jirong; Chen Tieguang

    2001-01-01

    60 Co γ gamma knife source is a kernel unit of γ knife therapy equipment. It has small active core, high specific activity, narrow half dark area, best focus form, long use period. The research of 60 Co γ knife sources are presented. Specifications of γ knife sources, technical parameters, safety performance, structure feature, procedure and quality control during research are discussed. 60 Co γ source consists of high specific activity cobalt pellets and double stainless steel sealed by argon arc welding. Its safety performance, surface contamination and leakage testing meet the requirements of GB 4075 and GB 4076

  14. Cobalt Fischer-Tropsch catalysts: influence of cobalt dispersion and titanium oxides promotion

    Energy Technology Data Exchange (ETDEWEB)

    Azib, H

    1996-04-10

    The aim of this work is to study the effect of Sol-Gel preparation parameters which occur in silica supported cobalt catalysts synthesis. These catalysts are particularly used for the waxes production in natural gas processing. The solids have been characterized by several techniques: transmission electron microscopy (TEM), X-ray absorption near edge spectroscopy (XANES), programmed temperature reduction (TPR), infrared spectroscopy (IR), ultraviolet spectroscopy (UV), Magnetism, thermodesorption of H{sub 2} (TPD). The results indicate that the control of the cobalt dispersion and oxide phases nature is possible by modifying Sol-Gel parameters. The catalytic tests in Fischer-Tropsch synthesis were conducted on a pilot unit under pressure (20 atm) and suggested that turnover rates were independent of Co crystallite size, Co phases in the solids (Co deg., cobalt silicate) and titanium oxide promotion. On the other methane, the C{sub 3}{sup +} hydrocarbon selectivity is increased with increasing crystallite size. Inversely, the methane production is favoured by very small crystallites, cobalt silicate increase and titanium addition. However, the latter, used as a cobalt promoter, has a benefic effect on the active phase stability during the synthesis. (author). 149 refs., 102 figs., 71 tabs.

  15. Electrocatalytic performance evaluation of cobalt hydroxide and cobalt oxide thin films for oxygen evolution reaction

    Science.gov (United States)

    Babar, P. T.; Lokhande, A. C.; Pawar, B. S.; Gang, M. G.; Jo, Eunjin; Go, Changsik; Suryawanshi, M. P.; Pawar, S. M.; Kim, Jin Hyeok

    2018-01-01

    The development of an inexpensive, stable, and highly active electrocatalyst for oxygen evolution reaction (OER) is essential for the practical application of water splitting. Herein, we have synthesized an electrodeposited cobalt hydroxide on nickel foam and subsequently annealed in an air atmosphere at 400 °C for 2 h. In-depth characterization of all the films using X-ray diffraction (XRD), X-ray photoelectron emission spectroscopy (XPS), field emission scanning electron microscopy (FE-SEM), electrochemical impedance spectroscopy (EIS) and linear sweep voltammetry (LSV) techniques, which reveals major changes for their structural, morphological, compositional and electrochemical properties, respectively. The cobalt hydroxide nanosheet film shows high catalytic activity with 290 mV overpotential at 10 mA cm-2 and 91 mV dec-1 Tafel slope and robust stability (24 h) for OER in 1 M KOH electrolyte compared to cobalt oxide (340 mV). The better OER activity of cobalt hydroxide in comparison to cobalt oxide originated from high active sites, enhanced surface, and charge transport capability.

  16. A computer controlled tele-cobalt unit

    International Nuclear Information System (INIS)

    Brace, J.A.

    1982-01-01

    A computer controlled cobalt treatment unit was commissioned for treating patients in January 1980. Initially the controlling computer was a minicomputer, but now the control of the therapy unit is by a microcomputer. The treatment files, which specify the movement and configurations necessary to deliver the prescribed dose, are produced on the minicomputer and then transferred to the microcomputer using minitape cartridges. The actual treatment unit is based on a standard cobalt unit with a few additional features e.g. the drive motors can be controlled either by the computer or manually. Since the treatment unit is used for both manual and automatic treatments, the operational procedure under computer control is made to closely follow the manual procedure for a single field treatment. The necessary safety features which protect against human, hardware and software errors as well as the advantages and disadvantages of computer controlled radiotherapy are discussed

  17. Creep-fatigue of low cobalt superalloys

    Science.gov (United States)

    Halford, G. R.

    1982-01-01

    Testing for the low cycle fatigue and creep fatigue resistance of superalloys containing reduced amounts of cobalt is described. The test matrix employed involves a single high temperature appropriate for each alloy. A single total strain range, again appropriate to each alloy, is used in conducting strain controlled, low cycle, creep fatigue tests. The total strain range is based upon the level of straining that results in about 10,000 cycles to failure in a high frequency (0.5 Hz) continuous strain-cycling fatigue test. No creep is expected to occur in such a test. To bracket the influence of creep on the cyclic strain resistance, strain hold time tests with ore minute hold periods are introduced. One test per composition is conducted with the hold period in tension only, one in compression only, and one in both tension and compression. The test temperatures, alloys, and their cobalt compositions that are under study are given.

  18. Process for obtaining cobalt and lanthanum nickelate

    International Nuclear Information System (INIS)

    Tapcov, V.; Samusi, N.; Gulea, A.; Horosun, I.; Stasiuc, V.; Petrenco, P.

    1999-01-01

    The invention relates to the process for obtaining polycrystalline ceramics of cobalt and lanthanum nickelate with the perovskite structure from coordinative hetero metallic compounds. The obtained products can be utilized in the industry in the capacity of catalysts. Summary of the invention consists in obtaining polycrystalline ceramics LaCoO 3 and LaNiO 3 with the perovskite structure by pyrolysis of the parent compounds, namely, the coordinative hetero metallic compounds of the lanthanum cobalt or lanthanum nickel. The pyrolysis of the parent compound runs during one hour at 800 C. The technical result of the invention consists in lowering the temperature of the parent compound pyrolysis containing the precise ratio of metals necessary for ceramics obtaining

  19. Cobalt oxides from crystal chemistry to physics

    CERN Document Server

    Raveau, Bernard

    2012-01-01

    Unparalleled in the breadth and depth of its coverage of all important aspects, this book systematically treats the electronic and magnetic properties of stoichiometric and non-stoichiometric cobaltites in both ordered and disordered phases. Authored by a pioneer and a rising star in the field, the monograph summarizes, organizes and streamlines the otherwise difficult-to-obtain information on this topic. An introductory chapter sets forth the crystal chemistry of cobalt oxides to lay the groundwork for an understanding of the complex phenomena observed in this materials class. Special emphasis is placed on a comprehensive discussion of cobaltite physical properties in different structural families. Providing a thorough introduction to cobalt oxides from a chemical and physical viewpoint as a basis for understanding their intricacies, this is a must-have for both experienced researchers as well as entrants to the field.

  20. Radiation accident of 60Co contamination. Mexico 1984

    International Nuclear Information System (INIS)

    1985-01-01

    The action taken to mitigate the consequences of a radiation accident occuring in the State of Chihuahua, Mexico, is described, when a no longer in use cobalt-60 teletherapy unit, with radioactive pellets still inside, was sold, unwittingly as ordinary scrap to be finally made into reinforced steel rods. The finished metallic items, unknowingly contaminated with cobalt-60, were subsequently sold in central and northern Mexico and in the United States of America. The junkyard, transport vehicle, several foundries and some streets of two cities and the road between them were also made radioactive by the accident. The discovery of and search for the radioactive metallic products is described as is their final disposal and the decontamination of the affected sites. Individual and collective radiation doses is estimated. (author)

  1. Quality assurance and accuracy in Co-60 radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Scarlat, F; Rebigan, F

    1995-12-01

    The characteristics of a set of 88 Co-60 sources ONCOBALT, are described. This set of radioactive sources is an original choice of a variety of cobalt sources in point of physical size and activity. It includes 5 activity groups of cells (stainless steel) among 2 and 12 mCi, 5 and 15 mm active length and 2, 2.5 and 3 mm external diameter, 4 activity groups of needle activities between 1.3 and 3.4 mCi, 15 and 20 mm active length, 1.8 mm external diameter. By an appropriate choice of activities, dimensions and geometry of irradiation we can get an error of max.5% as to the receive dose. The radioactive purity of cobalt is 99.9%. To meet the requirements in practical radiotherapy we checked the Co-60 sources by tests: tight test, mechanical test, corrosion test and contamination test that gave us full satisfaction.

  2. Design of database management system for 60Co container inspection system

    International Nuclear Information System (INIS)

    Liu Jinhui; Wu Zhifang

    2007-01-01

    The function of the database management system has been designed according to the features of cobalt-60 container inspection system. And the software related to the function has been constructed. The database querying and searching are included in the software. The database operation program is constructed based on Microsoft SQL server and Visual C ++ under Windows 2000. The software realizes database querying, image and graph displaying, statistic, report form and its printing, interface designing, etc. The software is powerful and flexible for operation and information querying. And it has been successfully used in the real database management system of cobalt-60 container inspection system. (authors)

  3. Photoionization of cobalt impuritiesin zinc oxide

    Czech Academy of Sciences Publication Activity Database

    Ivanov, V.; Godlewski, M.; Dejneka, Alexandr

    2015-01-01

    Roč. 252, č. 9 (2015), s. 1988-1992 ISSN 0370-1972 R&D Projects: GA MŠk(CZ) LM2011029; GA ČR GAP108/12/1941 Grant - others:SAFMAT(XE) CZ.2.16/3.1.00/22132 Institutional support: RVO:68378271 Keywords : absorption band * cobalt * photoionization * electron spin resonance * pulsed mode * ZnO Subject RIV: BM - Solid Matter Physics ; Magnetism Impact factor: 1.522, year: 2015

  4. Speciation studies of cobalt in sea water

    International Nuclear Information System (INIS)

    Toteja, R.S.D.; Sudersanan, M.; Iyer, R.K.

    1995-01-01

    Recent results on the speciation of cobalt in simulated and actual sea water is reported using ion exchangers. The influence of magnesium ions in affecting the composition of ion exchangers and subsequent interpretation of the results is discussed. The results indicated that Co +2 may predominate in both the simulated and actual sea water and the presence of other constituents in sea water does not affect the nature of complex species present. (author). 2 refs., 3 tabs., 1 fig

  5. Literature study on the physiology of cobalt

    International Nuclear Information System (INIS)

    Erzberger, A.

    1986-12-01

    This literature study analyses the metabolism of cobalt in the human body, focussing on its resorption and the influence of various parameters like its chemical form, antagonisms, etc. on the level of resorption rate. The value currently recommended by ICRP for resorption rates (f 1 factor) of 0,3 or 0,05 for man is examined for its confirmation or non-confirmation in literature. (orig./MG) [de

  6. Enhanced magnetocrystalline anisotropy in deposited cobalt clusters

    Energy Technology Data Exchange (ETDEWEB)

    Eastham, D.A.; Denby, P.M.; Kirkman, I.W. [Daresbury Laboratory, Daresbury, Warrington (United Kingdom); Harrison, A.; Whittaker, A.G. [Department of Chemistry, University of Edinburgh, Edinburgh (United Kingdom)

    2002-01-28

    The magnetic properties of nanomaterials made by embedding cobalt nanocrystals in a copper matrix have been studied using a SQUID magnetometer. The remanent magnetization at temperatures down to 1.8 K and the RT (room temperature) field-dependent magnetization of 1000- and 8000-atom (average-size) cobalt cluster samples have been measured. In all cases it has been possible to relate the morphology of the material to the magnetic properties. However, it is found that the deposited cluster samples contain a majority of sintered clusters even at cobalt concentrations as low as 5% by volume. The remanent magnetization of the 8000-atom samples was found to be bimodal, consisting of one contribution from spherical particles and one from touching (sintered) clusters. Using a Monte Carlo calculation to simulate the sintering it has been possible to calculate a size distribution which fits the RT superparamagnetic behaviour of the 1000-atom samples. The remanent magnetization for this average size of clusters could then be fitted to a simple model assuming that all the nanoparticles are spherical and have a size distribution which fits the superparamagnetic behaviour. This gives a value for the potential energy barrier height (for reversing the spin direction) of 2.0 {mu}eV/atom which is almost four times the accepted value for face-centred-cubic bulk cobalt. The remanent magnetization for the spherical component of the large-cluster sample could not be fitted with a single barrier height and it is conjectured that this is because the barriers change as a function of cluster size. The average value is 1.5 {mu}eV/atom but presumably this value tends toward the bulk value (0.5 {mu}eV/atom) for the largest clusters in this sample. (author)

  7. Cobalt metabolism and toxicology-A brief update

    Energy Technology Data Exchange (ETDEWEB)

    Simonsen, Lars Ole, E-mail: LOSimonsen@dadlnet.dk; Harbak, Henrik; Bennekou, Poul

    2012-08-15

    Cobalt metabolism and toxicology are summarized. The biological functions of cobalt are updated in the light of recent understanding of cobalt interference with the sensing in almost all animal cells of oxygen deficiency (hypoxia). Cobalt (Co{sup 2+}) stabilizes the transcriptional activator hypoxia-inducible factor (HIF) and thus mimics hypoxia and stimulates erythropoietin (Epo) production, but probably also by the same mechanism induces a coordinated up-regulation of a number of adaptive responses to hypoxia, many with potential carcinogenic effects. This means on the other hand that cobalt (Co{sup 2+}) also may have beneficial effects under conditions of tissue hypoxia, and possibly can represent an alternative to hypoxic preconditioning. Cobalt is acutely toxic in larger doses, and in mammalian in vitro test systems cobalt ions and cobalt metal are cytotoxic and induce apoptosis and at higher concentrations necrosis with inflammatory response. Cobalt metal and salts are also genotoxic, mainly caused by oxidative DNA damage by reactive oxygen species, perhaps combined with inhibition of DNA repair. Of note, the evidence for carcinogenicity of cobalt metal and cobalt sulfate is considered sufficient in experimental animals, but is as yet considered inadequate in humans. Interestingly, some of the toxic effects of cobalt (Co{sup 2+}) have recently been proposed to be due to putative inhibition of Ca{sup 2+} entry and Ca{sup 2+}-signaling and competition with Ca{sup 2+} for intracellular Ca{sup 2+}-binding proteins. The tissue partitioning of cobalt (Co{sup 2+}) and its time-dependence after administration of a single dose have been studied in man, but mainly in laboratory animals. Cobalt is accumulated primarily in liver, kidney, pancreas, and heart, with the relative content in skeleton and skeletal muscle increasing with time after cobalt administration. In man the renal excretion is initially rapid but decreasing over the first days, followed by a second, slow

  8. コバルト60ガンマ線照射による水溶液中におけるチロシナーゼの水和電子誘発不活性化機構

    OpenAIRE

    Terato, Hiroaki

    1995-01-01

    CONTENTS General Introduction / p1 Chapter 1. / p5 Hydrated-Induced Inactivation of Tyrosinase in Aqueous Solution by Exposure to Cobalt-60 Gamma-Rays.I.Cresolase Activity / p5 Chapter 2. / p20 Hydrated-Induced Inactivation of Tyrosinase in Aqueous Solution by Exposure to Cobalt-60 Gamma-Rays.II.Catecholase Activity / p20 General discussion / p38 Acknowledgements / p42

  9. Plasma sprayed samarium--cobalt permanent magnets

    International Nuclear Information System (INIS)

    Willson, M.C.; Janowiecki, R.J.

    1975-01-01

    Samarium--cobalt permanent magnets were fabricated by arc plasma spraying. This process involves the injection of relatively coarse powder particles into a high-temperature gas for melting and spraying onto a substrate. The technique is being investigated as an economical method for fabricating cobalt--rare earth magnets for advanced traveling wave tubes and cross-field amplifiers. Plasma spraying permits deposition of material at high rates over large areas with optional direct bonding to the substrate, and offers the ability to fabricate magnets in a variety of shapes and sizes. Isotropic magnets were produced with high coercivity and good reproducibility in magnetic properties. Post-spray thermal treatments were used to enhance the magnetic properties of sprayed deposits. Samarium--cobalt magnets, sprayed from samarium-rich powder and subjected to post-spray heat treatment, displayed energy products in excess of 9 million gauss-oersteds and coercive forces of approximately 6000 oersteds. Bar magnet arrays were constructed by depositing magnets on ceramic substrates. (auth)

  10. Sintered cobalt-rare earth intermetallic product

    International Nuclear Information System (INIS)

    Benz, M.C.

    1975-01-01

    A process is described for preparing novel sintered cobalt--rare earth intermetallic products which can be magnetized to form permanent magnets having stable improved magnetic properties. A cobalt--rare earth metal alloy is formed having a composition which at sintering temperature falls outside the composition covered by the single Co 5 R intermetallic phase on the rare earth richer side. The alloy contains a major amount of the Co 5 R intermetallic phase and a second solid CoR phase which is richer in rare earth metal content than the Co 5 R phase. The specific cobalt and rare earth metal content of the alloy is substantially the same as that desired in the sintered product. The alloy, in particulate form, is pressed into compacts and sintered to the desired density. The sintered product is comprised of a major amount of the Co 5 R solid intermetallic phase and up to about 35 percent of the product of the second solid CoR intermetallic phase which is richer in rare earth metal content than the Co 5 R phase

  11. Hot corrosion of low cobalt alloys

    Science.gov (United States)

    Stearns, C. A.

    1982-01-01

    The hot corrosion attack susceptibility of various alloys as a function of strategic materials content are investigated. Preliminary results were obtained for two commercial alloys, UDIMET 700 and Mar-M 247, that were modified by varying the cobalt content. For both alloys the cobalt content was reduced in steps to zero. Nickel content was increased accordingly to make up for the reduced cobalt but all other constituents were held constant. Wedge bar test samples were produced by casting. The hot corrosion test consisted of cyclically exposing samples to the high velocity flow of combustion products from an air-fuel burner fueled with jet A-1 and seeded with a sodium chloride aqueous solution. The flow velocity was Mach 0.5 and the sodium level was maintained at 0.5 ppm in terms of fuel plus air. The test cycle consisted of holding the test samples at 900 C for 1 hour followed by 3 minutes in which the sample could cool to room temperature in an ambient temperature air stream.

  12. Mobility and retention of Co-60 in soils in coastal areas

    International Nuclear Information System (INIS)

    Mahara, Y.; Kudo, A.

    1980-01-01

    The purpose of this study was to determine the mobility of radioactive cobalt ( 60 Co), a typical operating waste, in soils in coastal areas (where all Japanese commercial reactors are located). The results of this investigation may assist in evaluating a degree of safety for the future disposal of radioactive wastes underground. Freshwater and seawater were examined under both aerobic and anaerobic conditions by simulating the environmental conditions of the soils in coastal areas. More than 80% of 60 Co moves freely within soils covered by seawater under anaerobic conditions. Furthermore, the cobalt in the water phase can pass through a dialysis membrane with a pore size of 24 A. This indicates that the cobalt is either in ionic form or associated with materials of low molecular weight. On the other hand, more than 95% of 60 Co was retained by soils covered by freshwater under aerobic conditions. This cobalt, once fixed on soils, was not easily desorbed by seawater under anaerobic conditions. The results suggest that the mobility of cobalt disposed of underground is greatly enced by the initial environmental conditions in the soils in coastal areas. (H.K.)

  13. Cobalt metabolism and toxicology—A brief update

    International Nuclear Information System (INIS)

    Simonsen, Lars Ole; Harbak, Henrik; Bennekou, Poul

    2012-01-01

    Cobalt metabolism and toxicology are summarized. The biological functions of cobalt are updated in the light of recent understanding of cobalt interference with the sensing in almost all animal cells of oxygen deficiency (hypoxia). Cobalt (Co 2+ ) stabilizes the transcriptional activator hypoxia-inducible factor (HIF) and thus mimics hypoxia and stimulates erythropoietin (Epo) production, but probably also by the same mechanism induces a coordinated up-regulation of a number of adaptive responses to hypoxia, many with potential carcinogenic effects. This means on the other hand that cobalt (Co 2+ ) also may have beneficial effects under conditions of tissue hypoxia, and possibly can represent an alternative to hypoxic preconditioning. Cobalt is acutely toxic in larger doses, and in mammalian in vitro test systems cobalt ions and cobalt metal are cytotoxic and induce apoptosis and at higher concentrations necrosis with inflammatory response. Cobalt metal and salts are also genotoxic, mainly caused by oxidative DNA damage by reactive oxygen species, perhaps combined with inhibition of DNA repair. Of note, the evidence for carcinogenicity of cobalt metal and cobalt sulfate is considered sufficient in experimental animals, but is as yet considered inadequate in humans. Interestingly, some of the toxic effects of cobalt (Co 2+ ) have recently been proposed to be due to putative inhibition of Ca 2+ entry and Ca 2+ -signaling and competition with Ca 2+ for intracellular Ca 2+ -binding proteins. The tissue partitioning of cobalt (Co 2+ ) and its time-dependence after administration of a single dose have been studied in man, but mainly in laboratory animals. Cobalt is accumulated primarily in liver, kidney, pancreas, and heart, with the relative content in skeleton and skeletal muscle increasing with time after cobalt administration. In man the renal excretion is initially rapid but decreasing over the first days, followed by a second, slow phase lasting several weeks, and

  14. Pharmacokinetics of inorganic cobalt and a vitamin B12 supplement in the Thoroughbred horse: Differentiating cobalt abuse from supplementation.

    Science.gov (United States)

    Hillyer, L L; Ridd, Z; Fenwick, S; Hincks, P; Paine, S W

    2018-05-01

    While cobalt is an essential micronutrient for vitamin B 12 synthesis in the horse, at supraphysiological concentrations, it has been shown to enhance performance in human subjects and rats, and there is evidence that its administration in high doses to horses poses a welfare threat. Animal sport regulators currently control cobalt abuse via international race day thresholds, but this work was initiated to explore means of potentially adding to application of those thresholds since cobalt may be present in physiological concentrations. To devise a scientific basis for differentiation between presence of cobalt from bona fide supplementation and cobalt doping through the use of ratios. Six Thoroughbred horses were given 10 mL vitamin B 12 /cobalt supplement (Hemo-15 ® ; Vetoquinol, Buckingham, Buckinghamshire, UK., 1.5 mg B 12 , 7 mg cobalt gluconate = 983 μg total Co) as an i.v. bolus then an i.v. infusion (15 min) of 100 mg cobalt chloride (45.39 mg Co) 6 weeks later. Pre-and post-administration plasma and urine samples were analysed for cobalt and vitamin B 12 . Urine and plasma samples were analysed for vitamin B 12 using an immunoassay and cobalt concentrations were measured via ICP-MS. Baseline concentrations of cobalt in urine and plasma for each horse were subtracted from their cobalt concentrations post-administration for the PK analysis. Compartmental analysis was used for the determination of plasma PK parameters for cobalt using commercially available software. On administration of a vitamin B 12 /cobalt supplement, the ratio of cobalt to vitamin B 12 in plasma rapidly increased to approximately 3 and then rapidly declined below a ratio of 1 and then back to near baseline over the next week. On administration of 100 mg cobalt chloride, the ratio initially exceeded 10 in plasma and then declined with the lower 95% confidence interval remaining above a ratio of 1 for 7 days. For two horses with extended sampling, the plasma ratio remained above one for

  15. A novel method to synthesize cobalt oxide (Co3O4) nanowires from cobalt (Co) nanobowls

    DEFF Research Database (Denmark)

    Srivastava, Akhilesh Kumar; Madhavi, S.; Ramanujan, R.V.

    2010-01-01

    A novel method suitable for the synthesis of the cobalt oxide (Co3O4) nanowires at targeted regions is presented in this report. Cobalt (Co) nanobowls synthesized by colloidal crystal directed assembly were transformed into Co3O4 nanowires by a simple heat treatment process. Co nanobowls exhibited...... a two phase (h.c.p. + f.c.c.) microstructure while single phase microstructure was observed for Co3O4 nanowires. Ferromagnetic Co nanobowls showed a dependence of coercivity on bowl size while Co3O4 exhibited weak ferromagnetic behavior....

  16. The effects of zinc on cobalt deposition in PWRs: summary report

    International Nuclear Information System (INIS)

    Bennet, Peter

    1996-01-01

    An experiment has been performed in a PWR loop of the Halden reactor to investigate the effects of the addition of 50 ppb zinc to the coolant on the incorporation of cobalt into the oxide films on primary circuit constructional materials. This report summarises the results from the three phases of the test. It was shown that zinc addition inhibits the corrosion of both new metal surfaces and surfaces with well-established oxides; this results in thinner oxide layers and reduced incorporation of cobalt into the oxide. Generally, there were no significant differences between the deposition of cobalt-60 onto pre-oxidised and new metal surfaces. In Phase 1 of the experiment, Co-60 deposition rates (normalised to the circulating Co-60 concentration) were lower than those measured in previous experiments in the loop by factors in the range from 5 to 10. In Phase 2, differences were observed in the behaviour of iron- and nickel-based alloys: larger decreases in the deposition rate compared with Phase 1 took place for stainless steel samples (i.e. factors > 20), whilst decreases on nickel-based coupons were generally less than a factor of 5. Co-60 deposition rates onto stainless steel coupons newly installed for Phase 3 of the experiment were greater by an order of magnitude than on coupons which had been exposed for all three phases; i.e. they were similar to those observed in Phase 1. The mechanisms by which zinc acts to inhibit corrosion and the incorporation of activity into oxide layers are not fully understood. More experimental data are required to resolve this issue, including information on the chemical form of the zinc within the oxide layer. (author)

  17. Cerium and cobalt movement with litter leachate in a forest soil

    International Nuclear Information System (INIS)

    Thomas, W.A.

    1975-01-01

    Leachate containing 144 Ce and 60 Co from leaf litter of mockernut hickory (Carya tomentosa Nutt.) and black gum (Nyssa sylvatica Marsh.) trees was applied to a forest soil in three different treatments to estimate the rates at which these elements move downward after release in the litter layer: (a) single application, (b) single application at twice the concentration in (a), and (c) four periodic applications over 1 year. Regression b values describing the distribution of 144 Ce and 60 Co 4 years after the first applications did not differ significantly (P greater than 0.01) among treatments for either element, but movement by 144 Ce significantly exceeded that by 60 Co for all treatments. A combination of chemical and physical phenomena retained cerium and cobalt in the biologically active zones of soil, with the organic layer and upper 3 cm of mineral soil accounting for 68 percent of the 144 Ce and 91 percent of the 60 Co

  18. Study of complex formation of cobalt (II) and cobalt (III) in acrylamide aqueous solutions and in the phase of acrylamide hydrogel

    International Nuclear Information System (INIS)

    Ismailova, M.M.; Egorova, L.A.; Khamidov, B.O.

    1993-01-01

    Present article is devoted to study of complex formation of cobalt (II) and cobalt (III) in acrylamide aqueous solutions and in the phase of acrylamide hydrogel. The condition of cobalt in various rate of oxidation in acrylamide aqueous solutions was studied. The concentration conditions of stability of system Co(II)-Co(III) were defined. The composition of coordination compounds of cobalt (II) and cobalt (III) in acrylamide aqueous solutions and in the phase of acrylamide hydrogel was determined.

  19. Mitigation of cesium and cobalt contamination on the surfaces of RAM packages

    International Nuclear Information System (INIS)

    Krumhansl, J.; Bonhomme, F.; McConnell, P.; Kapoor, A.

    2004-01-01

    Techniques for mitigating the adsorption of 137 Cs and 60 Co on metal surfaces (e.g., RAM packages) exposed to contaminated water (e.g., spent-fuel pools) has been developed and experimentally verified. The techniques are also effective in removing some of the 60 Co and 137 Cs that may have been adsorbed on the surfaces after removal from the contaminated water. The principle for the 137 Cs mitigation technique is based upon ion-exchange processes. In contrast, 60 Co contamination primarily resides in minute particles of CRUD that become lodged on cask surfaces. CRUD is an insoluble Fe-Ni-Cr oxide that forms colloidal-sized particles as stainless steels corrode. Because of the similarity between Ni +2 and Co +2 , CRUD is able to scavenge and retain traces of cobalt as it forms. A number of organic compounds have a great specificity for combining with nickel and cobalt. Ongoing research is investigating the effectiveness of chemical complexing agent, EDTA, with regard to its ability to dissolve the host phase (CRUD) thereby liberating the entrained 60Co into a solution where it can be rinsed away

  20. Dosing of anaerobic granular sludge bioreactors with cobalt: Impact of cobalt retention on methanogenic activity

    KAUST Repository

    Fermoso, Fernando G.

    2010-12-01

    The effect of dosing a metal limited anaerobic sludge blanket (UASB) reactor with a metal pulse on the methanogenic activity of granular sludge has thus far not been successfully modeled. The prediction of this effect is crucial in order to optimize the strategy for metal dosage and to prevent unnecessary losses of resources. This paper describes the relation between the initial immobilization of cobalt in anaerobic granular sludge cobalt dosage into the reactor and the evolution of methanogenic activity during the subsequent weeks. An operationally defined parameter (A0· B0) was found to combine the amount of cobalt immobilized instantaneously upon the pulse (B0) and the amount of cobalt immobilized within the subsequent 24. h (A0). In contrast with the individual parameters A0 and B0, the parameter A0· B0 correlated significantly with the methanogenic activity of the sludge during the subsequent 16 or 35. days. This correlation between metal retention and activity evolution is a useful tool to implement trace metal dosing strategies for biofilm-based biotechnological processes. © 2010.

  1. Cobalt(I) and Cobalt(III) Cyclopentadienyl Complexes with New Silicon-branched Fluorous Tags

    Czech Academy of Sciences Publication Activity Database

    Strašák, Tomáš; Čermák, Jan; Červenková Šťastná, Lucie; Sýkora, Jan; Fajgar, Radek

    2014-01-01

    Roč. 159, MAR 2014 (2014), s. 15-20 ISSN 0022-1139 R&D Projects: GA ČR(CZ) GAP106/12/1372 Institutional support: RVO:67985858 Keywords : fluorous tag * cobalt complex * cyclopentadienyl complex Subject RIV: CC - Organic Chemistry Impact factor: 1.948, year: 2014

  2. 21 CFR 189.120 - Cobaltous salts and its derivatives.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 3 2010-04-01 2009-04-01 true Cobaltous salts and its derivatives. 189.120 Section 189.120 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... malt beverages as a foam stabilizer and to prevent “gushing.” (b) Food containing any added cobaltous...

  3. Removal of Cobalt Ions by Precipitate Foam Flotation

    Energy Technology Data Exchange (ETDEWEB)

    Jung, In Ha; Lee, Jung Won [Korea Atomic Energy Research Institute, Taejon (Korea)

    1998-09-30

    Simulated waste liquid containing 50 ppm cobalt ion was tested by precipitate flotation using a sodium lauryl sulfate as a collector. The effects of initial cobalt ion concentration, pH, surfactant concentration, flotation time, gas flow rate and foreign ions on removal efficiency of cobalt ion were studied. Pretreatment of the waste liquid with 35% H{sub 2}O{sub 2} prior to precipitate flotation made shift of optimal flotation pH from the strong alkalinity to weak alkaline range and made a favorable flotation of cobalt ion in wide range of pH. For the result of this experiment, 99.8% removal efficiency was obtained on the conditions of initial cobalt ion concentration 50 ppm, pH 9.5, gas flow rate 70 ml/min, flotation time 30 min. The simulate ion was formed to be the most harmful ion against removal of cobalt by precipitate flotation of the species which were tested. The presence of 0.1 M of SO{sub 4}{sup 2-} ion decreased removal efficiency of cobalt to 90% while the cobalt were almost entirely removed in the absence of sulfate ion. (author). 11 refs., 8 figs.

  4. Adsorption Study of Cobalt on Treated Granular Activated Carbon

    OpenAIRE

    Y. V. Hete; S. B. Gholase; R. U. Khope

    2012-01-01

    This study is carried out for the removal of cobalt from aqueous solution using granular activated carbon in combination with p-nitro benzoic acid at temperature 25±1 °C. The adsorption isotherm of cobalt on granular activated carbon has been determined and the data fitted reasonably well to the Langmuir and Freundlich isotherm for activated carbon.

  5. Adsorption Study of Cobalt on Treated Granular Activated Carbon

    Directory of Open Access Journals (Sweden)

    Y. V. Hete

    2012-01-01

    Full Text Available This study is carried out for the removal of cobalt from aqueous solution using granular activated carbon in combination with p-nitro benzoic acid at temperature 25±1 °C. The adsorption isotherm of cobalt on granular activated carbon has been determined and the data fitted reasonably well to the Langmuir and Freundlich isotherm for activated carbon.

  6. Microwave Mapping Demonstration Using the Thermochromic Cobalt Chloride Equilibrium

    Science.gov (United States)

    Nguyen, Vu D.; Birdwhistell, Kurt R.

    2014-01-01

    An update to the thermochromic cobalt(II) chloride equilibrium demonstration is described. Filter paper that has been saturated with aqueous cobalt(II) chloride is heated for seconds in a microwave oven, producing a color change. The resulting pink and blue map is used to colorfully demonstrate Le Châtelier's principle and to illuminate the…

  7. The role of cobalt on the creep of Waspaloy

    Science.gov (United States)

    Jarrett, R. N.; Chin, L.; Tien, J. K.

    1984-01-01

    Cobalt was systematically replaced with nickel in Waspaloy (which normally contains 13% Co) to determine the effects of cobalt on the creep behavior of this alloy. Effects of cobalt were found to be minimal on tensile strengths and microstructure. The creep resistance and the stress rupture resistance determined in the range from 704 to 760 C (1300 to 1400 C) were found to decrease as cobalt was removed from the standard alloy at all stresses and temperatures. Roughly a ten-fold drop in rupture life and a corresponding increase in minimum creep rate were found under all test conditions. Both the apparent creep activation energy and the matrix contribution to creep resistance were found to increase with cobalt. These creep effects are attributed to cobalt lowering the stacking fault energy of the alloy matrix. The creep resistance loss due to the removal of cobalt is shown to be restored by slightly increasing the gamma' volume fraction. Results are compared to a previous study on Udimet 700, a higher strength, higher gamma' volume fraction alloy with similar phase chemistry, in which cobalt did not affect creep resistance. An explanation for this difference in behavior based on interparticle spacing and cross-slip is presented.

  8. Potential for cobalt recovery from lateritic ores in Europe

    Science.gov (United States)

    Herrington, R.

    2012-04-01

    Cobalt is one of the 'critical metals' identified under the EU Raw Materials Initiative. Annually the global mine production of cobalt is around 55,000 tonnes,with Europe's industries consuming around 30% of that figure. Currently Europe produces around 27 tonnes of cobalt from mines in Finland although new capacity is planned. Co-bearing nickel laterite ores being mined in Greece, Macedonia and Kosovo where the cobalt is currently not being recovered (ores have typical analyses of 0.055% Co and >1% Ni,). These ores are currently treated directly in pyrometallurgical plants to recover the contained nickel and this process means there is no separate cobalt product produced. Hydrometallurgical treatment of mineralogically suitable laterite ores can recover the cobalt; for example Cuba recovers 3,500 tonnes of cobalt from its laterite mining operations, which are of a similar scale to the current European operations. Implementation of hydrometallurgical techniques is in its infancy in Europe with one deposit in Turkey planning to use atmospheric heap leaching to recover nickel and copper from oxide-dominated ores. More widespread implementation of these methods to mineralogically suitable ore types could unlock the highly significant undeveloped resources (with metal contents >0.04% Co and >1% Ni), which have been defined throughout the Balkans eastwards into Turkey. At a conservative estimate, this region has the potential to supply up to 30% of the EU cobalt requirements.

  9. Highly selective cobalt-catalyzed hydrovinylation of styrene

    NARCIS (Netherlands)

    Grutters, M.M.P.; Müller, C.; Vogt, D.

    2006-01-01

    The hydrovinylation reaction is a codimerization of a 1,3-diene or vinyl arene and ethene with great potential for fine chemicals and pharmaceuticals. For the first time, enantioselective cobalt-catalyzed hydrovinylations of styrene were achieved with a cobalt-based system bearing a chiral

  10. Cobalt ferrite nanoparticles under high pressure

    Energy Technology Data Exchange (ETDEWEB)

    Saccone, F. D.; Ferrari, S.; Grinblat, F.; Bilovol, V. [Instituto de Tecnologías y Ciencias de la Ingeniería, “Ing. H. Fernández Long,” Av. Paseo Colón 850 (1063), Buenos Aires (Argentina); Errandonea, D., E-mail: daniel.errandonea@uv.es [Departamento de Fisica Aplicada, Institut Universitari de Ciència dels Materials, Universitat de Valencia, c/ Doctor Moliner 50, E-46100 Burjassot, Valencia (Spain); Agouram, S. [Departamento de Física Aplicada y Electromagnetismo, Universitat de València, 46100 Burjassot, Valencia (Spain)

    2015-08-21

    We report by the first time a high pressure X-ray diffraction and Raman spectroscopy study of cobalt ferrite (CoFe{sub 2}O{sub 4}) nanoparticles carried out at room temperature up to 17 GPa. In contrast with previous studies of nanoparticles, which proposed the transition pressure to be reduced from 20–27 GPa to 7.5–12.5 GPa (depending on particle size), we found that cobalt ferrite nanoparticles remain in the spinel structure up to the highest pressure covered by our experiments. In addition, we report the pressure dependence of the unit-cell parameter and Raman modes of the studied sample. We found that under quasi-hydrostatic conditions, the bulk modulus of the nanoparticles (B{sub 0} = 204 GPa) is considerably larger than the value previously reported for bulk CoFe{sub 2}O{sub 4} (B{sub 0} = 172 GPa). In addition, when the pressure medium becomes non-hydrostatic and deviatoric stresses affect the experiments, there is a noticeable decrease of the compressibility of the studied sample (B{sub 0} = 284 GPa). After decompression, the cobalt ferrite lattice parameter does not revert to its initial value, evidencing a unit cell contraction after pressure was removed. Finally, Raman spectroscopy provides information on the pressure dependence of all Raman-active modes and evidences that cation inversion is enhanced by pressure under non-hydrostatic conditions, being this effect not fully reversible.

  11. Reload of cobalt 60 for the J S-6500 irradiator; Recarga de cobalto 60 para el irradiador JS-6500

    Energy Technology Data Exchange (ETDEWEB)

    Torres C, G; Mayoral G, V M

    1991-01-15

    The present work has the purpose to describe the activities of the reloads program of the industrial irradiator J S-6500, elaborated for satisfying part of the demand of services and as a first step, to guide the decision making by the part of the ININ authorities in front of a wide market of this service. (Author)

  12. Hot Corrosion of Cobalt-Base Alloys

    Science.gov (United States)

    1975-06-01

    Alloys 20. ABSTRACT (Continue on revet -se tside lf necessary and identify by block number) ~ lThe sodium sulfate-induced hot corrosion of cobalt and...Figures 12 and 13. The Na2 SO 4 was observed to form puddles on the oxide-covered specimen surface. An oxide slag was usually suspended in the... slag (black arrows) were suspended (30 sees at 1000°C in air). b) After washing the Na2SO 4 from the specimen, the exposed oxide surface was highly

  13. Future of U.S. cobalt irradiation

    International Nuclear Information System (INIS)

    Clouser, J.F.

    1995-01-01

    An examination of future cobalt needs requires us to review our base business, customer trends, technology trends, and people, the human aspect of our business. I am approaching this discussion from the perspective of a contract supplier of gamma irradiation services in the United States. The base business is comprised primarily of the sterilization of medical devices followed by containers, labware, food products, and other items. Since the core business is serving the medical industry, trends observed within medical device manufacturers can impact our growth and the type of services needed to support that industry. (author)

  14. HYDROCARBON FORMATION ON POLYMER-SUPPORTED COBALT

    Energy Technology Data Exchange (ETDEWEB)

    Benner, Linda S.; Perkins, Patrick; Vollhardt, K.Peter C.

    1980-10-01

    In this report we detail the synthesis catalytic chemistry of polystyrene supported {eta}{sup 5} ~cyclopentadienyl- dicarbonyl cobalt, CpCo(CO){sub 2}. This material is active in the hydrogenation of CO to saturated linear hydrocarbons and appears to retain its "homogeneous", mononuclear character during the course of its catalysis, During ·the course of our work 18% and 20% crosslinked analogs of polystyrene supported CpCo(CO){sub 2} were shown to exhibit limited catalytic activity and no CO activation.

  15. Bifunctional cobalt F-T catalysts

    Energy Technology Data Exchange (ETDEWEB)

    Miller, J.G.; Coughlin, P.K.; Yang, C.L.; Rabo, J.A.

    1986-03-01

    Results on the catalytic screening of Fischer-Tropsch catalysts containing shape selective components are reported. Catalysts consist of promoted cobalt intimately contacted with Union Carbide molecular sieves and were tested using a Berty type internally recycled reactor. Methods of preparation, promoters and shape selective components were varied and aimed at improving catalyst performance. Catalysts were developed demonstrating high C/sub 5/ + yields with high olefin content and low methane production while maintaining stability under both low and high H/sub 2/:CO ratio conditions.

  16. Nitrogen oxides storage catalysts containing cobalt

    Science.gov (United States)

    Lauterbach, Jochen; Snively, Christopher M.; Vijay, Rohit; Hendershot, Reed; Feist, Ben

    2010-10-12

    Nitrogen oxides (NO.sub.x) storage catalysts comprising cobalt and barium with a lean NO.sub.x storage ratio of 1.3 or greater. The NO.sub.x storage catalysts can be used to reduce NO.sub.x emissions from diesel or gas combustion engines by contacting the catalysts with the exhaust gas from the engines. The NO.sub.x storage catalysts can be one of the active components of a catalytic converter, which is used to treat exhaust gas from such engines.

  17. Study of Malayaite and Malayaite Cobalt Pigment

    International Nuclear Information System (INIS)

    Pina, C.; Arriola, H.; Nava, N.

    2005-01-01

    Calcium tin silicate, CaSnSiO 5 , called Malayaite is synthesized with equimolecular quantities of calcium oxide, silica and stannic oxide followed by a thermic process. In this work, the synthesis of Malayaite and the structure of a Malayaite-based pigment, Sn/Co pink, is investigated by X-ray diffraction and Mossbauer spectroscopy. The results indicate Malayaite and Cassiterite formation, but the ion cobalt incorporated in the Malayaite structure, diminishes the Cassiterite proportion and causes larger asymmetry in the environment of the tin atom.

  18. Low-Cobalt Powder-Metallurgy Superalloy

    Science.gov (United States)

    Harf, F. H.

    1986-01-01

    Highly-stressed jet-engine parts made with less cobalt. Udimet 700* (or equivalent) is common nickel-based superalloy used in hot sections of jet engines for many years. This alloy, while normally used in wrought condition, also gas-atomized into prealloyed powder-metallurgy (PM) product. Product can be consolidated by hot isostatically pressing (HIPPM condition) and formed into parts such as turbine disk. Such jet-engine disks "see" both high stresses and temperatures to 1,400 degrees F (760 degrees C).

  19. Association between cobalt allergy and dermatitis caused by leather articles

    DEFF Research Database (Denmark)

    Bregnbak, David; Thyssen, Jacob P; Zachariae, Claus

    2015-01-01

    BACKGROUND: Cobalt is a strong skin sensitizer and a prevalent contact allergen. Recent studies have recognized exposure to leather articles as a potential cause of cobalt allergy. OBJECTIVES: To examine the association between contact allergy to cobalt and a history of dermatitis resulting from...... exposure to leather. METHODS: A questionnaire case-control study was performed: the case group consisted of 183 dermatitis patients with a positive patch test reaction to cobalt chloride and a negative patch test reaction to potassium dichromate; the control group consisted of 621 dermatitis patients who...... did not react to either cobalt or chromium in patch testing. Comparisons were made by use of a χ(2) -test, Fisher's exact, and the Mann-Whitney test. Logistic regression analyses were used to test for associations while taking confounding factors into consideration. RESULTS: Leather was observed...

  20. Total body irradiation with a reconditioned cobalt teletherapy unit.

    Science.gov (United States)

    Evans, Michael D C; Larouche, Renée-Xavière; Olivares, Marina; Léger, Pierre; Larkin, Joe; Freeman, Carolyn R; Podgorsak, Ervin B

    2006-01-01

    While the current trend in radiotherapy is to replace cobalt teletherapy units with more versatile and technologically advanced linear accelerators, there remain some useful applications for older cobalt units. The expansion of our radiotherapy department involved the decommissioning of an isocentric cobalt teletherapy unit and the replacement of a column-mounted 4-MV LINAC that has been used for total body irradiation (TBI). To continue offering TBI treatments, we converted the decommissioned cobalt unit into a dedicated fixed-field total body irradiator and installed it in an existing medium-energy LINAC bunker. This article describes the logistical and dosimetric aspects of bringing a reconditioned cobalt teletherapy unit into clinical service as a total body irradiator.

  1. Treatment of radioactive liquid waste (Co-60) by sorption on Zeolite Na-A prepared from Iraqi kaolin

    International Nuclear Information System (INIS)

    Mustafa, Yasmen A.; Zaiter, Maysoon J.

    2011-01-01

    Highlights: ► Iraqi synthetic zeolite type Na-A has been suggested as ion exchange material to treat cobalt-60 in radioactive liquid waste which came from neutron activation for corrosion products. ► The ability of Na-A zeolite to remove cobalt from wastewater was checked for high cobalt concentration (822 mg/L) in addition to low cobalt concentration in the source sample (0.093 mg/L). ► The effects of important design variables on the zeolite column performance were studied these include initial concentration, flow rate, and bed depth. ► The experimental results show that high sorption capacity can be obtained at high influent concentration, low flow rate, and high bed depth. ► Higher column performance was obtained at higher bed depth. - Abstract: Iraqi synthetic zeolite type Na-A has been suggested as ion exchange material to treat cobalt-60 in radioactive liquid waste which came from neutron activation for corrosion products. Batch experiments were conducted to find out the equilibrium isotherm for source sample .The equilibrium isotherm for radioactive cobalt in the source sample showed unfavorable type, while the equilibrium isotherm for the total cobalt (the radioactive and nonradioactive cobalt) in the source sample showed a favorable type. The ability of Na-A zeolite to remove cobalt from wastewater was checked for high cobalt concentration (822 mg/L) in addition to low cobalt concentration in the source sample (0.093 mg/L). A good fitting for the experimental data with Langmuir equilibrium model was observed. Langmuir constant qm which is related to monolayer adsorption capacity for low and high cobalt concentration was determined to be 0.021 and 140 mg/g zeolite . The effects of important design variables on the zeolite column performance were studied these include initial concentration, flow rate, and bed depth. The experimental results have shown that high sorption capacity can be obtained at high influent concentration, low flow rate, and

  2. /sup 60/Co accumulation by freshwater plants under natural conditions

    Energy Technology Data Exchange (ETDEWEB)

    Trapeznikov, A V; Trapeznikova, V N [AN SSSR, Sverdlovsk. Inst. Ehkologii Rastenij i Zhivotnykh

    1979-03-01

    In search for effective bioindicators of radioactive contamination of cooler-reservoirs in atomic power plants the accumulation of /sup 60/Co by four species of higher aquatic plants most widely distributed in the Urals was studied, namely by Elodea canadensis, Ceratophyllum demersum, Lemna minor and Potamogeton pectinatus. It is shown that such plants as Ceratophyllum demersum and Elodea canadensis having the accumulation coefficients of /sup 60/Co 33,500 and 21,500, respectively, can be recommended as bioindicators of this radionuclide in reservoirs contaminated with radioactive cobalt.

  3. On 60Co accumulation by freshwater plants under natural conditions

    International Nuclear Information System (INIS)

    Trapeznikov, A.V.; Trapeznikova, V.N.

    1979-01-01

    In search for effective bioindicators of radioactive contamination of cooler-reservoirs in atomic power plants the accumulation of 60 Co by four species of higher aquatic plants most widely distributed in the Urals was studied, namely by Elodea canadensis, Ceratophyllum demersum, Lemna minor and Potamogeton pectinatus. It is shown that such plants as Ceratophyllum demersum and Elodea canadensis having the accumulation coefficients of 60 Co 33,500 and 21,500, respectively, can be recommended as bioindicators of this radionuclide in reservoirs contaminated with radioactive cobalt

  4. Experimental evidence for cobalt(III)-carbene radicals: key intermediates in cobalt(II)-based metalloradical cyclopropanation

    NARCIS (Netherlands)

    Lu, H.; Dzik, W.I.; Xu, X.; Wojtas, L.; de Bruin, B.; Zhang, X.P.

    2011-01-01

    New and conclusive evidence has been obtained for the existence of cobalt(III)-carbene radicals that have been previously proposed as the key intermediates in the underlying mechanism of metalloradical cyclopropanation by cobalt(II) complexes of porphyrins. In the absence of olefin substrates,

  5. Forward-planned intensity modulated radiation therapy using a cobalt source: A dosimetric study in breast cancer

    Directory of Open Access Journals (Sweden)

    Savino Cilla

    2013-01-01

    Full Text Available This analysis evaluates the feasibility and dosimetric results of a simplified intensity-modulated radiotherapy (IMRT treatment using a cobalt-therapy unit for post-operative breast cancer. Fourteen patients were included. Three plans per patient were produced by a cobalt-60 source: A standard plan with two wedged tangential beams, a standard tangential plan optimized without the use of wedges and a plan based on the forward-planned "field-in-field" IMRT technique (Co-FinF where the dose on each of the two tangential beams was split into two different segments and the two segments weight was determined with an iterative process. For comparison purposes, a 6-MV photon standard wedged tangential treatment plan was generated. D mean , D 98% , D 2% , V 95% , V 107%, homogeneity, and conformity indices were chosen as parameters for comparison. Co-FinF technique improved the planning target volume dose homogeneity compared to other cobalt-based techniques and reduced maximum doses (D 2% and high-dose volume (V 110% . Moreover, it showed a better lung and heart dose sparing with respect to the standard approach. The higher dose homogeneity may encourage the adoption of accelerated-hypofractionated treatments also with the cobalt sources. This approach can promote the spread of breast conservative treatment in developing countries.

  6. Synthesis and characterization of mixtures of cobalt and titanium oxides by mechanical alloyed and Sol-Gel

    International Nuclear Information System (INIS)

    Basurto S, R.; Bonifacio M, J.; Fernandez V, S. M.

    2009-01-01

    The mechanical alloyed techniques continued by combustion and Sol-Gel method, were used for the synthesis of CoTiO 3 . With the first technique was used Co 3 O 4 obtained in a balls mill SPEX in argon atmosphere, using cobalt nitrate and urea, the combustion is realized at 400 and 500 C, the characterization by X-ray diffraction showed the obtaining of the valence oxide mixed of cobalt with crystallite size from 10 to 12.5 nm and the particle size of 60 to 75 nm was obtained by scanning electron microscopy. To prepare the CoTiO 3 , the obtained Co 3 O 4 was mixed with TiO 2 on a relationship in weight (1:1) and with a milling time of 2.5 h and the combustion at 800 C. the mixed oxide of titanium cobalt was also obtained by the Sol-Gel technique starting from cobalt chloride and titanium propoxide in acetic-water acid, the gel is burned to temperature of 300, 500, 700 and 900 C, finding that this last temperature it is that provides the compound with crystalline size from 50 to 75 nm. (Author)

  7. Characterization of naturally occurring radioactive materials and Cobald-60 contaminated ferrous scraps from steel industries

    International Nuclear Information System (INIS)

    Chao, H.E.; Chiu, H.S.; Hunga, J.Y.; His, H.W.; Chen, Y.B.

    2002-01-01

    Since the occurrence of radioactively contaminated rebar incident in 1992, steel industries in Taiwan were encouraged by Atomic Energy Council (AEC) to install portal monitor to detect the abnormal radiation in shipments of metal scrap feed. From 1994 through 1999, there were 53 discoveries of radioactivity in ferrous scraps by steel companies. These include 15 orphan radioactive sources, 16 cobalt-60 contaminated rebars, 20 Naturally Occurring Radioactive Material (NORM) contaminated scraps, and two unknowns. Most NORM-contaminated scraps were from abroad. The NORM and cobalt-60 contaminated scraps were taken from the steel mills and analyzed in laboratory. The analytical results of scales and sludge sampled from NORM-contaminated scraps combining with the circumstantial evidences indicate that five possible industrial processes may be involved. They are oil production and treatment, heavy mineral sand benefication and rare earth processing, copper mining and processing, recovery of ammonium chloride by lime adsorption in Ammonium-soda process, and tailing of uranium enrichment process. The cobalt-60 activity and trace elements concentrations of contaminated rebars confirm that all of them were produced domestically in the period from Oct. 1982 to Jan. 1983, when the cobalt-60 sources were lost and entered the electric arc furnace to produce the contaminated rebars. (author)

  8. Preparation and characterization of electrodeposited cobalt nanowires

    Energy Technology Data Exchange (ETDEWEB)

    Irshad, M. I., E-mail: imrancssp@gmail.com; Mohamed, N. M., E-mail: noranimuti-mohamed@petronas.com.my [Department of Fundamental and Applied Sciences, Universiti Teknologi PETRONAS, 31750 PERAK (Malaysia); Ahmad, F., E-mail: faizahmad@petronas.com.my; Abdullah, M. Z., E-mail: zaki-abdullah@petronas.com.my [Department of Mechanical Engineering, Universiti Teknologi PETRONAS, 31750 PERAK (Malaysia)

    2014-10-24

    Electrochemical deposition technique has been used to deposit cobalt nanowires into the nano sized channels of Anodized Aluminium Oxide (AAO) templates. CoCl{sub 2}Ðœ‡6H2O salt solution was used, which was buffered with H{sub 3}BO{sub 3} and acidified by dilute H{sub 2}SO{sub 4} to increase the plating life and control pH of the solution. Thin film of copper around 150 nm thick on one side of AAO template coated by e-beam evaporation system served as cathode to create electrical contact. FESEM analysis shows that the as-deposited nanowires are highly aligned, parallel to one another and have high aspect ratio with a reasonably high pore-filing factor. The TEM results show that electrodeposited cobalt nanowires are crystalline in nature. The Hysteresis loop shows the magnetization properties for in and out of plane configuration. The in plane saturation magnetization (Ms) is lower than out of plane configuration because of the easy axis of magnetization is perpendicular to nanowire axis. These magnetic nanowires could be utilized for applications such as spintronic devices, high density magnetic storage, and magnetic sensor applications.

  9. Preparation and characterization of electrodeposited cobalt nanowires

    International Nuclear Information System (INIS)

    Irshad, M. I.; Mohamed, N. M.; Ahmad, F.; Abdullah, M. Z.

    2014-01-01

    Electrochemical deposition technique has been used to deposit cobalt nanowires into the nano sized channels of Anodized Aluminium Oxide (AAO) templates. CoCl 2 Ðœ‡6H2O salt solution was used, which was buffered with H 3 BO 3 and acidified by dilute H 2 SO 4 to increase the plating life and control pH of the solution. Thin film of copper around 150 nm thick on one side of AAO template coated by e-beam evaporation system served as cathode to create electrical contact. FESEM analysis shows that the as-deposited nanowires are highly aligned, parallel to one another and have high aspect ratio with a reasonably high pore-filing factor. The TEM results show that electrodeposited cobalt nanowires are crystalline in nature. The Hysteresis loop shows the magnetization properties for in and out of plane configuration. The in plane saturation magnetization (Ms) is lower than out of plane configuration because of the easy axis of magnetization is perpendicular to nanowire axis. These magnetic nanowires could be utilized for applications such as spintronic devices, high density magnetic storage, and magnetic sensor applications

  10. Investigations on the formation of cobalt thiomolybdates

    Energy Technology Data Exchange (ETDEWEB)

    Prasad, S [Paraiba Univ., Joao Pessoa (Brazil). Dept. de Engenharia Quimica

    1984-06-01

    The reactions between Co/sup 2 +/ and different thiomolybdate anions (MoS/sup 2 -//sub 4/, Mo/sub 4/S/sup 6 -//sub 15/, Mo/sub 2/S/sup 2 -//sub 7/ and Mo/sub 4/S/sup 2 -//sub 13/) have been investigated by means of glass electrode and conductometric titrations between the reactants at several concentrations. The results provide definite evidence for the formation of CoS.MoS/sub 3/ and 3CoS.4MoS/sub 3/ around pH 7.1 and 5.9, respectively. The titrations of cobalt chloride with Na/sub 2/S.2MoS/sub 3/ and Na/sub 2/S.4MoS/sub 3/ failed to provide any dependable results for the formation of the corresponding cobalt thiomolybdates. The accuracy and reproducibility of these titrations are of high order. Analytical investigations of these compounds have also been carried out and substantiate the results of the pH and conductometric measurements.

  11. Spin-dependent transport in cobalt nanocontacts

    Energy Technology Data Exchange (ETDEWEB)

    Sarau, G.

    2007-04-16

    The magnetoresistance response of cobalt nanocontacts with varying geometries formed between two extended electrodes has been experimentally investigated and linked to micromagnetic simulations. The contribution of the nanoconstriction to the measured magnetoresistance signal has been separated from that of the electrode bulk. The different nanocontact geometries exhibit different shape anisotropies resulting in a characteristic behavior of the magnetization at each nanocontact. The magnetization reversal processes are explained on the basis of the anisotropic magnetoresistance and domain wall scattering effects. The domain wall resistance takes positive values, which is in agreement with models based on the spin mistracking inside the domain wall. The 4 K MR measurements are found to be influenced by the exchange bias effect between the ferromagnetic cobalt electrodes and the antiferromagnetic oxidized Co surface. When cooling down in an applied magnetic field, the uniform biased Co layer behaves as if it possesses a unidirectional anisotropy axis along the field cooling direction. In the zero field cooling case, the exchange bias varies locally throughout the sample giving rise to non-reproducible successive MR traces. (orig.)

  12. A spot test for detection of cobalt release – early experience and findings

    DEFF Research Database (Denmark)

    Thyssen, Jacob P.; Menné, Torkil; Johansen, Jeanne D.

    2010-01-01

    Background: It is often difficult to establish clinical relevance of metal exposure in cobalt-allergic patients. Dermatologists and patients may incorrectly assume that many metallic items release cobalt at levels that may cause cobalt dermatitis. Cobalt-allergic patients may be unaware that they...

  13. A spot test for detection of cobalt release - early experience and findings

    DEFF Research Database (Denmark)

    Thyssen, Jacob P; Menné, Torkil; Johansen, Jeanne D

    2010-01-01

    It is often difficult to establish clinical relevance of metal exposure in cobalt-allergic patients. Dermatologists and patients may incorrectly assume that many metallic items release cobalt at levels that may cause cobalt dermatitis. Cobalt-allergic patients may be unaware that they are exposed...

  14. Magnetoresistance in cobalt-contacted multi-wall carbon nanotubes

    International Nuclear Information System (INIS)

    Vinzelberg, H.; Zhao, B.; Moench, I.; Schumann, J.; Schneider, C.M.

    2005-01-01

    We present results for magnetotransport measurements on multiwall-carbon nanotubes (MWCNT) contacted by cobalt electrodes. By measuring the V(I) characteristics at constant magnetic fields and different orientation of the magnetization directions in the Co electrodes, we were able to determine both current and voltage dependences of the magnetoresistance (MR) effects. These tunneling MR values are compared with the directly measured MR at constant current with sweeping magnetic field. The V(I) curves show an ohmic behavior at 295 K and a non-linear tunneling behavior at 4.2 K. With decreasing bias current the MR increased up to 60% at 4.2 K, and with decreasing bias voltages even up to 175%. The MR disappears at high bias current (voltages) and temperatures higher than 40 K. For most of the samples the current dependences of the MR were found to be nearly symmetric upon reversing the current direction. However, in some cases we also observed a sign change of the MR as function of the applied current, which suggests an inversion of the spin polarization in one of the Co interfaces

  15. Synthesis of cobalt boride nanoparticles using radio frequency thermal plasma

    International Nuclear Information System (INIS)

    Lapitan, Jr. Lorico DS.; Ying Ying Chen; Seesoek Choe; Watanabe, Takayuki

    2012-01-01

    Nano size cobalt boride particles were synthesized from vapor phase using a 30 kw-4 MHz radio frequency (RF) thermal plasma. Cobalt and boron powder mixtures used as precursors in different composition and feed rate were evaporated immediately in the high temperature plasma and cobalt boride nanoparticles were produced through the quenching process. The x-ray diffractometry (XRD) patterns of cobalt boride nanoparticles prepared from the feed powder ratio of 1:2 and 1:3 for Co: B showed peaks that are associated with the Co 2 B and CoB crystal phases of cobalt boride. The XRD analysis revealed that increasing the powder feed rate results in a higher mass fraction and a larger crystalline diameter of cobalt boride nanoparticles. The images obtained by field emission scanning electron microscopy (FE-SEM) revealed that cobalt boride nanoparticles have a spherical morphology. The crystallite size of the particles estimated with XRD was found to be 18-22 nm. (author)

  16. Nickel-cobalt hydroxide nanosheets: Synthesis, morphology and electrochemical properties.

    Science.gov (United States)

    Schneiderová, Barbora; Demel, Jan; Zhigunov, Alexander; Bohuslav, Jan; Tarábková, Hana; Janda, Pavel; Lang, Kamil

    2017-08-01

    This paper reports the synthesis, characterization, and electrochemical performance of nickel-cobalt hydroxide nanosheets. The hydroxide nanosheets of approximately 0.7nm thickness were prepared by delamination of layered nickel-cobalt hydroxide lactate in water and formed transparent colloids that were stable for months. The nanosheets were deposited on highly oriented pyrolytic graphite by spin coating, and their electrochemical behavior was investigated by cyclic voltammetry in potassium hydroxide electrolyte. Our method of electrode preparation allows for studying the electrochemistry of nanosheets where the majority of the active centers can participate in the charge transfer reaction. The observed electrochemical response was ascribed to mutual compensation of the cobalt and nickel response via electron sharing between these metals in the hydroxide nanosheets, a process that differentiates the behavior of nickel-cobalt hydroxide nanosheets from single nickel hydroxide or cobalt hydroxide nanosheets or their physical mixture. The presence of cobalt in the nickel-cobalt hydroxide nanosheets apparently decreases the time of electrochemical activation of the nanosheet layer, which for the nickel hydroxide nanosheets alone requires more potential sweeps. Copyright © 2017 Elsevier Inc. All rights reserved.

  17. Smoothing an isolated interface of cobalt-copper under irradiation by low-energy argon ions

    International Nuclear Information System (INIS)

    Stognij, A.I.; Novitskij, N.N.; Stukalov, O.M.

    2003-01-01

    Multilayer film structures, i.e. gold layer-copper-cobalt, are considered. It is shown that the structure, where cobalt surface prior to copper layer deposition was subjected to additional irradiation by a flow of argon ions, features the smoothest surface. The conclusion is made about smoothing out of cobalt-copper interface as a result of multiple collisions of argon slow ions and cobalt atoms during braking within two or three upper atomic rows of the cobalt layer [ru

  18. Incentives and opportunities for reducing the cobalt content in reactor core components

    International Nuclear Information System (INIS)

    Ocken, H.

    1985-01-01

    Cobalt in core components contributes to radiation field buildup on out-of-core surfaces. Core components containing cobalt-base alloys and cobalt as an impurity are identified. The use of cobalt-free wear-resistant alloys and construction materials with lower impurity levels of cobalt is disused. It is argued that such measures are cost effective. Lower radiation fields and disposal costs will offset higher raw material costs. Component performance will not be affected. (author)

  19. The structural evolution and diffusion during the chemical transformation from cobalt to cobalt phosphide nanoparticles

    KAUST Repository

    Ha, Don-Hyung

    2011-01-01

    We report the structural evolution and the diffusion processes which occur during the phase transformation of nanoparticles (NPs), ε-Co to Co 2P to CoP, from a reaction with tri-n-octylphosphine (TOP). Extended X-ray absorption fine structure (EXAFS) investigations were used to elucidate the changes in the local structure of cobalt atoms which occur as the chemical transformation progresses. The lack of long-range order, spread in interatomic distances, and overall increase in mean-square disorder compared with bulk structure reveal the decrease in the NP\\'s structural order compared with bulk structure, which contributes to their deviation from bulk-like behavior. Results from EXAFS show both the Co2P and CoP phases contain excess Co. Results from EXAFS, transmission electron microscopy, X-ray diffraction, and density functional theory calculations reveal that the inward diffusion of phosphorus is more favorable at the beginning of the transformation from ε-Co to Co2P by forming an amorphous Co-P shell, while retaining a crystalline cobalt core. When the major phase of the sample turns to Co 2P, the diffusion processes reverse and cobalt atom out-diffusion is favored, leaving a hollow void, characteristic of the nanoscale Kirkendall effect. For the transformation from Co2P to CoP theory predicts an outward diffusion of cobalt while the anion lattice remains intact. In real samples, however, the Co-rich nanoparticles continue Kirkendall hollowing. Knowledge about the transformation method and structural properties provides a means to tailor the synthesis and composition of the NPs to facilitate their use in applications. © 2011 The Royal Society of Chemistry.

  20. Electrochemical performance of cobalt hydroxide nanosheets formed by the delamination of layered cobalt hydroxide in water

    Czech Academy of Sciences Publication Activity Database

    Schneiderová, Barbora; Demel, Jan; Pleštil, Josef; Tarábková, Hana; Bohuslav, Jan; Lang, Kamil

    2014-01-01

    Roč. 43, č. 27 (2014), s. 10484-10491 ISSN 1477-9226 R&D Projects: GA ČR GP13-09462P Institutional support: RVO:61388980 ; RVO:61388955 ; RVO:61389013 Keywords : Ray-absorption spectroscopy * Alpha-cobalt * Solvothermal decomposition * Nickel * Nanocomposites Subject RIV: CA - Inorganic Chemistry; CD - Macromolecular Chemistry (UMCH-V) Impact factor: 4.197, year: 2014